Reconstruction-free sensitive wavefront sensor based on continuous position sensitive detectors.
Godin, Thomas; Fromager, Michael; Cagniot, Emmanuel; Brunel, Marc; Aït-Ameur, Kamel
2013-12-01
We propose a new device that is able to perform highly sensitive wavefront measurements based on the use of continuous position sensitive detectors and without resorting to any reconstruction process. We demonstrate experimentally its ability to measure small wavefront distortions through the characterization of pump-induced refractive index changes in laser material. In addition, it is shown using computer-generated holograms that this device can detect phase discontinuities as well as improve the quality of sharp phase variations measurements. Results are compared to reference Shack-Hartmann measurements, and dramatic enhancements are obtained.
Automatic burst detection for the EEG of the preterm infant.
Jennekens, Ward; Ruijs, Loes S; Lommen, Charlotte M L; Niemarkt, Hendrik J; Pasman, Jaco W; van Kranen-Mastenbroek, Vivianne H J M; Wijn, Pieter F F; van Pul, Carola; Andriessen, Peter
2011-10-01
To aid with prognosis and stratification of clinical treatment for preterm infants, a method for automated detection of bursts, interburst-intervals (IBIs) and continuous patterns in the electroencephalogram (EEG) is developed. Results are evaluated for preterm infants with normal neurological follow-up at 2 years. The detection algorithm (MATLAB®) for burst, IBI and continuous pattern is based on selection by amplitude, time span, number of channels and numbers of active electrodes. Annotations of two neurophysiologists were used to determine threshold values. The training set consisted of EEG recordings of four preterm infants with postmenstrual age (PMA, gestational age + postnatal age) of 29-34 weeks. Optimal threshold values were based on overall highest sensitivity. For evaluation, both observers verified detections in an independent dataset of four EEG recordings with comparable PMA. Algorithm performance was assessed by calculation of sensitivity and positive predictive value. The results of algorithm evaluation are as follows: sensitivity values of 90% ± 6%, 80% ± 9% and 97% ± 5% for burst, IBI and continuous patterns, respectively. Corresponding positive predictive values were 88% ± 8%, 96% ± 3% and 85% ± 15%, respectively. In conclusion, the algorithm showed high sensitivity and positive predictive values for bursts, IBIs and continuous patterns in preterm EEG. Computer-assisted analysis of EEG may allow objective and reproducible analysis for clinical treatment.
Implementation of Complex Signal Processing Algorithms for Position-Sensitive Microcalorimeters
NASA Technical Reports Server (NTRS)
Smith, Stephen J.
2008-01-01
We have recently reported on a theoretical digital signal-processing algorithm for improved energy and position resolution in position-sensitive, transition-edge sensor (POST) X-ray detectors [Smith et al., Nucl, lnstr and Meth. A 556 (2006) 2371. PoST's consists of one or more transition-edge sensors (TES's) on a large continuous or pixellated X-ray absorber and are under development as an alternative to arrays of single pixel TES's. PoST's provide a means to increase the field-of-view for the fewest number of read-out channels. In this contribution we extend the theoretical correlated energy position optimal filter (CEPOF) algorithm (originally developed for 2-TES continuous absorber PoST's) to investigate the practical implementation on multi-pixel single TES PoST's or Hydras. We use numerically simulated data for a nine absorber device, which includes realistic detector noise, to demonstrate an iterative scheme that enables convergence on the correct photon absorption position and energy without any a priori assumptions. The position sensitivity of the CEPOF implemented on simulated data agrees very well with the theoretically predicted resolution. We discuss practical issues such as the impact of random arrival phase of the measured data on the performance of the CEPOF. The CEPOF algorithm demonstrates that full-width-at- half-maximum energy resolution of < 8 eV coupled with position-sensitivity down to a few 100 eV should be achievable for a fully optimized device.
Segmented AC-coupled readout from continuous collection electrodes in semiconductor sensors
Sadrozinski, Hartmut F. W.; Seiden, Abraham; Cartiglia, Nicolo
2017-04-04
Position sensitive radiation detection is provided using a continuous electrode in a semiconductor radiation detector, as opposed to the conventional use of a segmented electrode. Time constants relating to AC coupling between the continuous electrode and segmented contacts to the electrode are selected to provide position resolution from the resulting configurations. The resulting detectors advantageously have a more uniform electric field than conventional detectors having segmented electrodes, and are expected to have much lower cost of production and of integration with readout electronics.
Teacher-Parent Partnerships. ERIC Digest.
ERIC Educational Resources Information Center
Swick, Kevin J.
Research provides insight into parent attributes that support partnerships with teachers. These attributes include warmth, sensitivity, nurturance, the ability to listen, consistency, positive self-image, personal competence, and effective interpersonal skills. Researchers have cited positive attitudes, continuous teacher training, involvement in…
40 CFR 799.9537 - TSCA in vitro mammalian chromosome aberration test.
Code of Federal Regulations, 2012 CFR
2012-07-01
... demonstrates the sensitivity of the test system. Positive control concentrations should be chosen so that the... aberration test. 799.9537 Section 799.9537 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT (CONTINUED) IDENTIFICATION OF SPECIFIC CHEMICAL SUBSTANCE AND...
40 CFR 799.9537 - TSCA in vitro mammalian chromosome aberration test.
Code of Federal Regulations, 2011 CFR
2011-07-01
... demonstrates the sensitivity of the test system. Positive control concentrations should be chosen so that the... aberration test. 799.9537 Section 799.9537 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT (CONTINUED) IDENTIFICATION OF SPECIFIC CHEMICAL SUBSTANCE AND...
Amorim, Edilberto; Williamson, Craig A; Moura, Lidia M V R; Shafi, Mouhsin M; Gaspard, Nicolas; Rosenthal, Eric S; Guanci, Mary M; Rajajee, Venkatakrishna; Westover, M Brandon
2017-07-01
Continuous EEG screening using spectrograms or compressed spectral arrays (CSAs) by neurophysiologists has shorter review times with minimal loss of sensitivity for seizure detection when compared with visual analysis of raw EEG. Limited data are available on the performance characteristics of CSA-based seizure detection by neurocritical care nurses. This is a prospective cross-sectional study that was conducted in two academic neurocritical care units and involved 33 neurointensive care unit nurses and four neurophysiologists. All nurses underwent a brief training session before testing. Forty two-hour CSA segments of continuous EEG were reviewed and rated for the presence of seizures. Two experienced clinical neurophysiologists masked to the CSA data performed conventional visual analysis of the raw EEG and served as the gold standard. The overall accuracy was 55.7% among nurses and 67.5% among neurophysiologists. Nurse seizure detection sensitivity was 73.8%, and the false-positive rate was 1-per-3.2 hours. Sensitivity and false-alarm rate for the neurophysiologists was 66.3% and 1-per-6.4 hours, respectively. Interrater agreement for seizure screening was fair for nurses (Gwet AC1 statistic: 43.4%) and neurophysiologists (AC1: 46.3%). Training nurses to perform seizure screening utilizing continuous EEG CSA displays is feasible and associated with moderate sensitivity. Nurses and neurophysiologists had comparable sensitivities, but nurses had a higher false-positive rate. Further work is needed to improve sensitivity and reduce false-alarm rates.
Los Pactos entre Padres y Maestros (Teacher-Parent Partnerships). ERIC Digest.
ERIC Educational Resources Information Center
Swick, Kevin J.
Research provides insight into parent attributes that support partnerships with teachers. These attributes include warmth, sensitivity, nurturance, the ability to listen, consistency, positive self-image, personal competence, and effective interpersonal skills. Researchers have cited positive attitudes, continuous teacher training, involvement in…
JiaoShi-JiaZhang De HeZuo (Teacher-Parent Partnerships). ERIC Digest.
ERIC Educational Resources Information Center
Swick, Kevin J.
Research provides insight into parent attributes that support partnerships with teachers. These attributes include warmth, sensitivity, nurturance, the ability to listen, consistency, positive self-image, personal competence, and effective interpersonal skills. Researchers have cited positive attitudes, continuous teacher training, involvement in…
32 CFR 154.60 - Evaluating continued security eligibility.
Code of Federal Regulations, 2011 CFR
2011-07-01
... in sensitive positions who are experiencing problems in their personal lives with respect to such... personal problem which may have a bearing upon the individual's continued eligibility for access. (1) In... potential problem areas at an early stage so that any assistance rendered by the employing activity will...
32 CFR 154.60 - Evaluating continued security eligibility.
Code of Federal Regulations, 2010 CFR
2010-07-01
... in sensitive positions who are experiencing problems in their personal lives with respect to such... personal problem which may have a bearing upon the individual's continued eligibility for access. (1) In... potential problem areas at an early stage so that any assistance rendered by the employing activity will...
Garnier, A; Poncet, F; Billette De Villemeur, A; Exbrayat, C; Bon, M F; Chevalier, A; Salicru, B; Tournegros, J M
2009-06-01
The screening program guidelines specify that the call back rate of women for additional imaging (positive mammogram) should not exceed 7% at initial screening, and 5% at subsequent screening. Materials and methods. Results in the Isere region (12%) have prompted a review of the correlation between the call back rate and indicators of quality (detection rate, sensitivity, specificity, positive predictive value) for the radiologists providing interpretations during that time period. Three groups of radiologists were identified: the group with call back rate of 10% achieved the best results (sensitivity: 92%, detection rate: 0.53%, specificity: 90%). The group with lowest call back rate (7.7%) showed insufficient sensitivity (58%). The last group with call back rate of 18.3%, showed no improvement in sensitivity (82%) and detection rate (0.53%), but showed reduced specificity (82%). The protocol update in 2001 does not resolve this problematic situation and national results continue to demonstrate a high percentage of positive screening mammograms. A significant increase in the number of positive screening examinations compared to recommended guidelines is not advantageous and leads to an overall decrease in the quality of the screening.
Online and offline tools for head movement compensation in MEG.
Stolk, Arjen; Todorovic, Ana; Schoffelen, Jan-Mathijs; Oostenveld, Robert
2013-03-01
Magnetoencephalography (MEG) is measured above the head, which makes it sensitive to variations of the head position with respect to the sensors. Head movements blur the topography of the neuronal sources of the MEG signal, increase localization errors, and reduce statistical sensitivity. Here we describe two novel and readily applicable methods that compensate for the detrimental effects of head motion on the statistical sensitivity of MEG experiments. First, we introduce an online procedure that continuously monitors head position. Second, we describe an offline analysis method that takes into account the head position time-series. We quantify the performance of these methods in the context of three different experimental settings, involving somatosensory, visual and auditory stimuli, assessing both individual and group-level statistics. The online head localization procedure allowed for optimal repositioning of the subjects over multiple sessions, resulting in a 28% reduction of the variance in dipole position and an improvement of up to 15% in statistical sensitivity. Offline incorporation of the head position time-series into the general linear model resulted in improvements of group-level statistical sensitivity between 15% and 29%. These tools can substantially reduce the influence of head movement within and between sessions, increasing the sensitivity of many cognitive neuroscience experiments. Copyright © 2012 Elsevier Inc. All rights reserved.
High-sensitivity detection of TNT
Pushkarsky, Michael B.; Dunayevskiy, Ilya G.; Prasanna, Manu; Tsekoun, Alexei G.; Go, Rowel; Patel, C. Kumar N.
2006-01-01
We report high-sensitivity detection of 2,4,6-trinitrotoluene (TNT) by using laser photoacoustic spectroscopy where the laser radiation is obtained from a continuous-wave room temperature high-power quantum cascade laser in an external grating cavity geometry. The external grating cavity quantum cascade laser is continuously tunable over ≈400 nm around 7.3 μm and produces a maximum continuous-wave power of ≈200 mW. The IR spectroscopic signature of TNT is sufficiently different from that of nitroglycerine so that unambiguous detection of TNT without false positives from traces of nitroglycerine is possible. We also report the results of spectroscopy of acetylene in the 7.3-μm region to demonstrate continuous tunability of the IR source. PMID:17164325
Urinary tract infections in pregnancy: evaluation of diagnostic framework.
Jido, Tukur Ado
2014-01-01
This study was performed with the objective to examine the diagnostic framework for urinary tract infection (UTI) in pregnancy and physician response to the clinical diagnosis and to correlate responses to the results of urine culture and sensitivity. Over a 6-month period, 81 consecutive patients attending the labor ward admission of a district general hospital with the diagnosis of UTI during pregnancy were analyzed. Relevant information on symptom complex, result of dipstick urinalysis and culture and sensitivity were recorded. Data were analyzed using descriptive statistics. Of the 78 patients analyzed, 79% had increased urinary frequency, 73.1% had suprapubic pains and 53.1% had dysuria. All the patients had urinalysis with dipsticks, 41 (52.6%) were positive for nitrites and 64 (82.1%) were positive for leukocyte esterase. All 78 patients had urine culture and sensitivity, 21 (26.8%) of who were positive, and coliforms were the most commonly isolated pathogens. The sensitivity for nitrite was 80.9%, specificity 57.9% and positive predictive value 41.4%. The corresponding figures for leukocyte esterase were sensitivity 100%, specificity 24.6% and positive predictive value 32.8%. Sixty-six (84.6%) patients had treatment started on the basis of the clinical diagnosis, mostly with co-amoxyclavullinic acid or amoxicillin alone. A high resistance rate to these empirically chosen antibiotics was seen in the sensitivity pattern of isolated pathogens. Current clinical diagnostic algorithms for the diagnosis of UTI when applied in the context of pregnancy have low specificity and positive predictive values; yet, empirical antibiotics are frequently employed on this basis. These are often not in keeping with the sensitivity pattern of isolated organisms. There is need for a continuing research for more specific bedside tests.
Code of Federal Regulations, 2011 CFR
2011-07-01
... the flow sensor and other necessary equipment in a position that provides a representative flow. (2) Use a flow sensor with a measurement sensitivity of no greater than 2 percent of the expected process... sensor(s) in a position that provides a representative measurement of the pressure (e.g., particulate...
Real, Ruben G. L.; Kotchoubey, Boris; Kübler, Andrea
2014-01-01
This study aimed at evaluating the performance of the Studentized Continuous Wavelet Transform (t-CWT) as a method for the extraction and assessment of event-related brain potentials (ERP) in data from a single subject. Sensitivity, specificity, positive (PPV) and negative predictive values (NPV) of the t-CWT were assessed and compared to a variety of competing procedures using simulated EEG data at six low signal-to-noise ratios. Results show that the t-CWT combines high sensitivity and specificity with favorable PPV and NPV. Applying the t-CWT to authentic EEG data obtained from 14 healthy participants confirmed its high sensitivity. The t-CWT may thus be well suited for the assessment of weak ERPs in single-subject settings. PMID:25309308
Real, Ruben G L; Kotchoubey, Boris; Kübler, Andrea
2014-01-01
This study aimed at evaluating the performance of the Studentized Continuous Wavelet Transform (t-CWT) as a method for the extraction and assessment of event-related brain potentials (ERP) in data from a single subject. Sensitivity, specificity, positive (PPV) and negative predictive values (NPV) of the t-CWT were assessed and compared to a variety of competing procedures using simulated EEG data at six low signal-to-noise ratios. Results show that the t-CWT combines high sensitivity and specificity with favorable PPV and NPV. Applying the t-CWT to authentic EEG data obtained from 14 healthy participants confirmed its high sensitivity. The t-CWT may thus be well suited for the assessment of weak ERPs in single-subject settings.
Administrative database code accuracy did not vary notably with changes in disease prevalence.
van Walraven, Carl; English, Shane; Austin, Peter C
2016-11-01
Previous mathematical analyses of diagnostic tests based on the categorization of a continuous measure have found that test sensitivity and specificity varies significantly by disease prevalence. This study determined if the accuracy of diagnostic codes varied by disease prevalence. We used data from two previous studies in which the true status of renal disease and primary subarachnoid hemorrhage, respectively, had been determined. In multiple stratified random samples from the two previous studies having varying disease prevalence, we measured the accuracy of diagnostic codes for each disease using sensitivity, specificity, and positive and negative predictive value. Diagnostic code sensitivity and specificity did not change notably within clinically sensible disease prevalence. In contrast, positive and negative predictive values changed significantly with disease prevalence. Disease prevalence had no important influence on the sensitivity and specificity of diagnostic codes in administrative databases. Copyright © 2016 Elsevier Inc. All rights reserved.
McQueen, Margaret M; Duckworth, Andrew D; Aitken, Stuart A; Court-Brown, Charles M
2013-04-17
The aim of our study was to document the estimated sensitivity and specificity of continuous intracompartmental pressure monitoring for the diagnosis of acute compartment syndrome. From our prospective trauma database, we identified all patients who had sustained a tibial diaphyseal fracture over a ten-year period. A retrospective analysis of 1184 patients was performed to record and analyze the documented use of continuous intracompartmental pressure monitoring and the use of fasciotomy. A diagnosis of acute compartment syndrome was made if there was escape of muscles at fasciotomy and/or color change in the muscles or muscle necrosis intraoperatively. A diagnosis of acute compartment syndrome was considered incorrect if it was possible to close the fasciotomy wounds primarily at forty-eight hours. The absence of acute compartment syndrome was confirmed by the absence of neurological abnormality or contracture at the time of the latest follow-up. Of 979 monitored patients identified, 850 fit the inclusion criteria with a mean age of thirty-eight years (range, twelve to ninety-four years), and 598 (70.4%) were male (p < 0.001). A total of 152 patients (17.9%) underwent fasciotomy for the treatment of acute compartment syndrome: 141 had acute compartment syndrome (true positives), six did not have it (false positives), and five underwent fasciotomy despite having a normal differential pressure reading, with subsequent operative findings consistent with acute compartment syndrome (false negatives). Of the 698 patients (82.1%) who did not undergo fasciotomy, 689 had no evidence of any late sequelae of acute compartment syndrome (true negatives) at a mean follow-up time of fifty-nine weeks. The estimated sensitivity of intracompartmental pressure monitoring for suspected acute compartment syndrome was 94%, with an estimated specificity of 98%, an estimated positive predictive value of 93%, and an estimated negative predictive value of 99%. The estimated sensitivity and specificity of continuous intracompartmental pressure monitoring for the diagnosis of acute compartment syndrome following tibial diaphyseal fracture are high; continuous intracompartmental pressure monitoring should be considered for patients at risk for acute compartment syndrome.
Code of Federal Regulations, 2011 CFR
2011-07-01
... this section. (1) Install the flow sensor and other necessary equipment in a position that provides a representative flow. (2) Use a flow sensor with a measurement sensitivity of no greater than 2 percent of the...) Install the pressure sensor(s) in a position that provides a representative measurement of the pressure (e...
Mizokawa, Ai
2013-01-01
Caregivers' emotional responses to children influence children's social and emotional development. This study investigated the association between maternal emotional expressiveness in the context of mother-child interactions and young children's sensitivity to teacher criticism. Sensitivity to teacher criticism was assessed among 53 Japanese preschoolers using hypothetical scenarios in which a puppet child representing the participant made a small error, and a puppet teacher pointed out the error. Self-report questionnaires were used to measure maternal expressiveness. The results demonstrated that negative maternal expressiveness toward one's own children was positively related to children's ratings of their own ability and negatively related to children's motivation to continue with the task after teacher criticism. Positive maternal expressiveness was not related to children's sensitivity to criticism. These findings suggest that children who have experienced more negative emotion from mothers may be more likely to hold negative beliefs about how others will respond to their behavior more generally. This may, in turn, lead to a defensively positive view of one's own abilities and a disinclination to persevere as protection from additional opportunities for teacher evaluation.
Alternate Waveforms for a Low-Cost Civil Global Positioning System Receiver.
1980-06-01
implementation. 17 Is. D i* on. S’ *. l7Gfo ai" ositioning System Navigation Receiver DOCUMENT IS AVAILASLe TO THE PUSLIC THROUGH THE NATIONAL TECHNICALRanging...be included were ranging performance, data hand- ling capability, time-to-first fix, acquisition and re-acquisition capability, and sensitivity to...seconds). This receiver would exhibit less sensitivity to multipath and to signal dropouts because it would continuously track all satellites in view and
Puckett, A; Pratt, G
1987-01-01
A comparison of cardiolipin and a modified Treponema pallidum haemagglutination assay (TPHA) method over a four year period confirmed the superior sensitivity and specificity of TPHA. In 86,495 new donor sera 19 (0.02%) confirmed positive results were detected by TPHA, 10 of which did not react by the cardiolipin test. In 150,789 antenatal samples 49 confirmed positive results were found by TPHA, 30 of which did not react by cardiolipin. No cardiolipin positive, TPHA negative samples were confirmed as positive by the absorbed fluorescence treponemal antibody test, and overall 78% of cardiolipin reactions gave false biological positive results. Cardiolipin tests were continued only because of their speed. A further modification ("spin") of the TPHA has now been developed which is rapid, sensitive, and inexpensive, and in testing 21,807 sera, gave results equivalent to those of the previous "settle" method. Serious consideration should be given to dispensing with cardiolipin tests. PMID:3320095
Assessment of need for transport tubes when continuously monitoring for radioactive aerosols.
Whicker, J J; Rodgers, J C; Lopez, R C
1999-09-01
Aerosol transport tubes are often used to draw aerosol from desirable sampling locations to nearby air sampling equipment that cannot be placed at that location. In many plutonium laboratories at Los Alamos National Laboratory, aerosol transport tubes are used to transport aerosol from the front of room ventilation exhaust registers to continuous air monitors (CAMs) that are mounted on nearby walls. Transport tubes are used because past guidance suggests that extraction of aerosol samples from exhaust locations provides the most sensitive and reliable detection under conditions where the rooms have unpredictable release locations and significant spatial variability in aerosol concentrations after releases, and where CAMs cannot be located in front of exhaust registers without blocking worker walkways. Despite designs to minimize particle loss in tubes, aerosol transport model predictions suggest losses occur lowering the sensitivity of CAMs to accidentally released plutonium aerosol. The goal of this study was to test the hypotheses that the reliability, speed, and sensitivity of aerosol detection would be equal whether the sample was extracted from the front of the exhaust register or from the wall location of CAMs. Polydisperse oil aerosols were released from multiple locations in two plutonium laboratories to simulate plutonium aerosol releases. Networked laser particle counters (LPCs) were positioned to simultaneously measure time-resolved aerosol concentrations at each exhaust register (representative of sampling with transport tubes) and at each wall-mounted CAM location (representative of sampling without transport tubes). Results showed no significant differences in detection reliability, speed, or sensitivity for LPCs positioned at exhaust locations when compared to LPCs positioned at the CAM wall location. Therefore, elimination of transport tubes would likely improve CAM performance.
Both hand position and movement direction modulate visual attention
Festman, Yariv; Adam, Jos J.; Pratt, Jay; Fischer, Martin H.
2013-01-01
The current study explored effects of continuous hand motion on the allocation of visual attention. A concurrent paradigm was used to combine visually concealed continuous hand movements with an attentionally demanding letter discrimination task. The letter probe appeared contingent upon the moving right hand passing through one of six positions. Discrimination responses were then collected via a keyboard press with the static left hand. Both the right hand's position and its movement direction systematically contributed to participants' visual sensitivity. Discrimination performance increased substantially when the right hand was distant from, but moving toward the visual probe location (replicating the far-hand effect, Festman et al., 2013). However, this effect disappeared when the probe appeared close to the static left hand, supporting the view that static and dynamic features of both hands combine in modulating pragmatic maps of attention. PMID:24098288
Luetkemeyer, Anne F; Kendall, Michelle A; Wu, Xingye; Lourenço, Maria Cristina; Jentsch, Ute; Swindells, Susan; Qasba, Sarojini S; Sanchez, Jorge; Havlir, Diane V; Grinsztejn, Beatriz; Sanne, Ian M; Firnhaber, Cynthia
2014-04-01
Limited performance data from line probe assays (LPAs), nucleic acid tests used for the rapid diagnosis of tuberculosis (TB), nontuberculosis mycobacteria (NTM), and Mycobacterium tuberculosis drug resistance are available for HIV-infected individuals, in whom paucibacillary TB is common. In this study, the strategy of testing sputum with GenoType MTBDRplus (MTBDR-Plus) and GenoType Direct LPA (Direct LPA) was compared to a gold standard of one mycobacterial growth indicator tube (MGIT) liquid culture. HIV-positive (HIV(+)) individuals with suspected TB from southern Africa and South America with <7 days of TB treatment had 1 sputum specimen tested with Direct LPA, MTBDR-Plus LPA, smear microscopy, MGIT, biochemical identification of mycobacterial species, and culture-based drug-susceptibility testing (DST). Of 639 participants, 59.3% were MGIT M. tuberculosis culture positive, of which 276 (72.8%) were acid-fast bacillus (AFB) smear positive. MTBDR-Plus had a sensitivity of 81.0% and a specificity of 100%, with sensitivities of 44.1% in AFB smear-negative versus 94.6% in AFB smear-positive specimens. For specimens that were positive for M. tuberculosis by MTBDR-Plus, the sensitivity and specificity for rifampin resistance were 91.7% and 96.6%, respectively, and for isoniazid (INH) they were 70.6% and 99.1%. The Direct LPA had a sensitivity of 88.4% and a specificity of 94.6% for M. tuberculosis detection, with a sensitivity of 72.5% in smear-negative specimens. Ten of 639 MGIT cultures grew Mycobacterium avium complex or Mycobacterium kansasii, half of which were detected by Direct LPA. Both LPA assays performed well in specimens from HIV-infected individuals, including in AFB smear-negative specimens, with 72.5% sensitivity for M. tuberculosis identification with the Direct LPA and 44.1% sensitivity with MTBDR-Plus. LPAs have a continued role for use in settings where rapid identification of INH resistance and clinically relevant NTM are priorities.
Naeger, D M; Chang, S D; Kolli, P; Shah, V; Huang, W; Thoeni, R F
2011-01-01
Objective The study compared the sensitivity, specificity, confidence and interpretation time of readers of differing experience in diagnosing acute appendicitis with contrast-enhanced CT using neutral vs positive oral contrast agents. Methods Contrast-enhanced CT for right lower quadrant or right flank pain was performed in 200 patients with neutral and 200 with positive oral contrast including 199 with proven acute appendicitis and 201 with other diagnoses. Test set disease prevalence was 50%. Two experienced gastrointestinal radiologists, one fellow and two first-year residents blindly assessed all studies for appendicitis (2000 readings) and assigned confidence scores (1=poor to 4=excellent). Receiver operating characteristic (ROC) curves were generated. Total interpretation time was recorded. Each reader's interpretation with the two agents was compared using standard statistical methods. Results Average reader sensitivity was found to be 96% (range 91–99%) with positive and 95% (89–98%) with neutral oral contrast; specificity was 96% (92–98%) and 94% (90–97%). For each reader, no statistically significant difference was found between the two agents (sensitivities p-values >0.6; specificities p-values>0.08), in the area under the ROC curve (range 0.95–0.99) or in average interpretation times. In cases without appendicitis, positive oral contrast demonstrated improved appendix identification (average 90% vs 78%) and higher confidence scores for three readers. Average interpretation times showed no statistically significant differences between the agents. Conclusion Neutral vs positive oral contrast does not affect the accuracy of contrast-enhanced CT for diagnosing acute appendicitis. Although positive oral contrast might help to identify normal appendices, we continue to use neutral oral contrast given its other potential benefits. PMID:20959365
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Locate the temperature sensor in a position that provides a representative temperature. (ii) Use a temperature sensor with a measurement sensitivity of 4 degrees Fahrenheit or 0.75 percent of the temperature value, whichever is larger. (iii) Shield the temperature sensor system from electromagnetic interference...
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Locate the temperature sensor in a position that provides a representative temperature. (ii) Use a temperature sensor with a measurement sensitivity of 4 degrees Fahrenheit or 0.75 percent of the temperature value, whichever is larger. (iii) Shield the temperature sensor system from electromagnetic interference...
The role of lymphocyte proliferation tests in assessing occupational sensitization and disease
Hines, Stella E.; Pacheco, Karin; Maier, Lisa A.
2018-01-01
Purpose of Review Lymphocyte proliferation testing (LPT) is used in diagnosing occupationally-acquired delayed-type hypersensitivity. It has been used in beryllium-health effects, and it role is expanding in metal allergy. It may find application in diagnosis of other sensitizers. Recent findings Use of the beryllium LPT (BeLPT) in medical surveillance identifies beryllium sensitization at low exposure with chronic beryllium disease (CBD) that leads to physiologic impairment and need for immunosuppressive medications. New studies indicate that both beryllium exposure and genetic variation are associated with increased risk of CBD. Borderline positive BeLPTs warrant inclusion into diagnostic algorithms. Furthermore, use of LPTs to diagnose metal allergy is being proposed in diagnosis of chromium allergy and hypersensitivity to surgical implants. New occupational sensitizers continue to be identified including metalworking fluids, the sterilizing agent ortho-phthalaldehyde and the solvent parachlorobenzotrifluoride. Use of LPT in occupational surveillance to these agents, and other known sensitizers may play expanding roles. Summary Lymphocyte proliferation testing serves a valuable role in diagnosing occupational sensitization, as demonstrated with beryllium-health effects, as cases continue to be found at low exposure levels. The use of LPTs in diagnosing contact allergy is expanding, and new applications may be identified in human and animal studies. PMID:22306552
Towards automatic patient positioning and scan planning using continuously moving table MR imaging.
Koken, Peter; Dries, Sebastian P M; Keupp, Jochen; Bystrov, Daniel; Pekar, Vladimir; Börnert, Peter
2009-10-01
A concept is proposed to simplify patient positioning and scan planning to improve ease of use and workflow in MR. After patient preparation in front of the scanner the operator selects the anatomy of interest by a single push-button action. Subsequently, the patient table is moved automatically into the scanner, while real-time 3D isotropic low-resolution continuously moving table scout scanning is performed using patient-independent MR system settings. With a real-time organ identification process running in parallel and steering the scanner, the target anatomy can be positioned fully automatically in the scanner's sensitive volume. The desired diagnostic examination of the anatomy of interest can be planned and continued immediately using the geometric information derived from the acquired 3D data. The concept was implemented and successfully tested in vivo in 12 healthy volunteers, focusing on the liver as the target anatomy. The positioning accuracy achieved was on the order of several millimeters, which turned out to be sufficient for initial planning purposes. Furthermore, the impact of nonoptimal system settings on the positioning performance, the signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) was investigated. The present work proved the basic concept of the proposed approach as an element of future scan automation. (c) 2009 Wiley-Liss, Inc.
A Comparative Analysis of Coprologic Diagnostic Methods for Detection of Toxoplama gondii in Cats
Salant, Harold; Spira, Dan T.; Hamburger, Joseph
2010-01-01
The relative role of transmission of Toxoplasma gondii infection from cats to humans appears to have recently increased in certain areas. Large-scale screening of oocyst shedding in cats cannot rely on microscopy because oocyst identification lacks sensitivity and specificity, or on bioassays, which require test animals and weeks before examination. We compared a sensitive and species-specific coprologic–polymerase chain reaction (copro-PCR) for detection of T. gondii infected cats with microscopy and a bioassay. In experimentally infected cats followed over time, microscopy was positive occasionally, and positive copro-PCR and bioassay results were obtained continuously from days 2 to 24 post-infection. The copro-PCR is at least as sensitive and specific as the bioassay and is capable of detecting infective oocysts during cat infection. Therefore, this procedure can be used as the new gold standard for determining potential cat infectivity. Its technologic advantages over the bioassay make it superior for large-scale screening of cats. PMID:20439968
NASA Technical Reports Server (NTRS)
Desantis, A.
1994-01-01
In this paper the approximation problem for a class of optimal compensators for flexible structures is considered. The particular case of a simply supported truss with an offset antenna is dealt with. The nonrational positive real optimal compensator transfer function is determined, and it is proposed that an approximation scheme based on a continued fraction expansion method be used. Comparison with the more popular modal expansion technique is performed in terms of stability margin and parameters sensitivity of the relative approximated closed loop transfer functions.
Ukraine: Current Issues and U.S. Policy
2017-01-03
state. Occupying the sensitive position between Russia and North Atlantic Treaty Organization (NATO) member states Poland, Slovakia, Hungary, and...Intelligence Unit (EIU), “dismantling ingrained structures of corruption will continue to meet with considerable resistance from organized business...economic component of the former Soviet Union, producing about four times the output of the next-ranking republic. Its fertile soil generated more
C. T. Scott; R. Hernandez; C. Frihart; R. Gleisner; T. Tice
2005-01-01
A new method for quantifying percentage wood failure of an adhesively bonded block-shear specimen has been developed. This method incorporates a laser displacement gage with an automated two-axis positioning system that functions as a highly sensitive profilometer. The failed specimen is continuously scanned across its width to obtain a surface failure profile. The...
NASA Astrophysics Data System (ADS)
Herrero, Vicente; Colom, Ricardo; Gadea, Rafael; Lerche, Christoph W.; Cerdá, Joaquín; Sebastiá, Ángel; Benlloch, José M.
2007-06-01
Silicon Photomultipliers, though still under development for mass production, may be an alternative to traditional Vacuum Photomultipliers Tubes (VPMT). As a consequence, electronic front-ends initially designed for VPMT will need to be modified. In this simulation, an improved architecture is presented which is able to obtain impact position and depth of interaction of a gamma ray within a continuous scintillation crystal, using either kind of PM. A current sensitive preamplifier stage with individual gain adjustment interfaces the multi-anode PM outputs with a current division resistor network. The preamplifier stage allows to improve front-end processing delay and temporal resolution behavior as well as to increase impact position calculation resolution. Depth of interaction (DOI) is calculated from the width of the scintillation light distribution, which is related to the sum of voltages in resistor network input nodes. This operation is done by means of a high-speed current mode scheme.
NASA Astrophysics Data System (ADS)
Nadhira, Vebi; Kurniadi, Deddy; Juliastuti, E.; Sutiswan, Adeline
2014-03-01
The importance of monitoring the quality of vegetables and fruits is prosperity by giving a competitive advantage for producer and providing a more healthy food for consumer. Diffuse Optical Tomography (DOT) is offering the possibility to detect the internal defects of the agricultural produce quality. Fluorescence diffuse optical tomography (FDOT) is the development of DOT, offering the possibilities to improve spatial resolution and to contrast image. The purpose of this research is to compare FDOT and DOT in forward analysis with continuous wave approach. The scattering and absorbing parameters of potatoes are used to represent the real condition. The object was illuminated by the NIR source from some positions on the boundary of object. A set of NIR detector are placed on the peripheral position of the object to measure the intensity of propagated or emitted light. In the simulation, we varied a condition of object then we analyzed the sensitivity of forward problem. The result of this study shows that FDOT has a better sensitivity than DOT and a better potential to monitor internal defects of agricultural produce because of the contrast value between optical and fluorescence properties of agricultural produce normal tissue and defects.
Xu, Chengdong; Dodbiba, Edra; Padivitage, Nilusha L T; Breitbach, Zachary S; Armstrong, Daniel W
2012-12-30
The detection of metal cations continues to be essential in many scientific and industrial areas of interest. The most common electrospray ionization mass spectrometry (ESI-MS) approach involves chelating the metal ions and detecting the organometallic complex in the negative ion mode. However, it is well known that negative ion mode ESI-MS is generally less sensitive than the positive ion mode. To achieve greater sensitivity, it is necessary to examine the feasibility of detecting the chelated metal cations in positive ion mode ESI-MS. Since highly solvated native metal cations have relatively low ionization efficiency in ESI-MS, and can be difficult to detect in the positive ion mode, a tetracationic ion-pairing agent was added to form a complex with the negatively charged metal chelate. The use of the ion-pairing agent leads to the generation of an overall positively charged complex, which can be detected at higher m/z values in the positive ion mode by electrospray ionization linear quadrupole ion trap mass spectrometry. Thirteen chelating agents with diverse structures were evaluated in this study. The nature of the chelating agent played as important a role as was previously determined for cationic pairing agents. The detection limits of six metal cations reached sub-picogram levels and significant improvements were observed when compared to negative ion mode detection where the metal-chelates were monitored without adding the ion-pairing reagent (IPR). Also, selective reaction monitoring (SRM) analyses were performed on the ternary complexes, which improved detection limits by one to three orders of magnitude. With this method it was possible to analyze the metal cations in the positive ion mode ESI-MS with the advantage of speed, sensitivity and selectivity. The optimum solution pH for this type of analysis is 5-7. Tandem mass spectrometry (MS/MS) further increases the sensitivity. Speciation is straightforward making this a broadly useful approach for the analysis of metal ions. Copyright © 2012 John Wiley & Sons, Ltd.
Disenrollment from Medicare HMOs.
Call, K T; Dowd, B E; Feldman, R; Lurie, N; McBean, M A; Maciejewski, M
2001-01-01
Since the program's inception, there has been great interest in determining whether beneficiaries who enter and subsequently leave Medicare health maintenance organizations (HMOs) are more or less costly than those remaining in fee-for-service (FFS) Medicare. To examine whether relatively high-cost beneficiaries disenroll from Medicare HMOs (disenrollment bias) and whether disenrollment bias varies by Medicare HMO market characteristics. In addition, we compare rates of surgical procedures and hospitalizations for ambulatory care-sensitive conditions for disenrollees and continuing FFS beneficiaries. Cross-sectional analysis of 1994 Medicare data. Medicare beneficiaries were first sampled from the 124 counties with at least 1000 Medicare HMO enrollees. From this pool, HMO disenrollees and a sample of continuing FFS beneficiaries were drawn. The FFS beneficiaries were assigned dates of "pseudodisenrollment." Expenditures and inpatient service use were compared for 6 months after disenrollment or pseudodisenrollment. The HMO disenrollees were no more likely than the continuing FFS beneficiaries to have positive total expenditures (Part A plus Part B) or Part B expenditures in the first 6 months after disenrollment. However, disenrollees were more likely to have Part A expenditures. Among beneficiaries with spending, disenrollees had higher total and Part B expenditures than continuing FFS beneficiaries. Moreover, the disparity in total and Part B spending between disenrollees and continuing FFS beneficiaries increased with HMO market penetration. Although Part A spending was higher for disenrollees with spending, it was not sensitive to changes in market share. The HMO disenrollees received more surgical procedures and were hospitalized for more of the ambulatory care-sensitive conditions than the FFS beneficiaries. On several measures, Medicare HMOs experienced favorable disenrollment relative to continuing FFS beneficiaries as recently as 1994, which increased as HMO market share increased.
Ukraine: Current Issues and U.S. Policy
2014-05-08
Ukrainian government committed to reforms. In May 2014, the Ukrainian government received the first installment of a $17 billion IMF loan. The European...sensitive position between Russia and NATO member states Poland, Slovakia, Hungary, and Romania adds to its geostrategic significance. Many Russian...continue their efforts at destabilization unhindered. After Ukraine re-launched an “anti-terrorist operation” on April 23 (after setbacks on a first
NASA Astrophysics Data System (ADS)
Babb, A.; Thomas, A.; Bletery, Q.
2017-12-01
Low frequency earthquakes (LFEs) are detected at depths of 16-30 km on a 150 km section of the San Andreas Fault centered at Parkfield, CA. The LFEs are divided into 88 families based on waveform similarity. Each family is thought to represent a brittle asperity on the fault surface that repeatedly slips during aseismic slip of the surrounding fault. LFE occurrence is irregular which allows families to be divided into continuous and episodic. In continuous families a burst of a few LFE events recurs every few days while episodic families experience essentially quiescent periods often lasting months followed by bursts of hundreds of events over a few days. The occurrence of LFEs has also been shown to be sensitive to extremely small ( 1kPa) tidal stress perturbations. However, the clustered nature of LFE occurrence could potentially bias estimates of tidal sensitivity. Here we re-evaluate the tidal sensitivity of LFE families on the deep San Andreas using a declustered catalog. In this catalog LFE bursts are isolated based on the recurrence intervals between individual LFE events for each family. Preliminary analysis suggests that declustered LFE families are still highly sensitive to tidal stress perturbations, primarily right-lateral shear stress (RLSS) and to a lesser extent fault normal stress (FNS). We also find inferred creep episodes initiate preferentially during times of positive RLSS.
Tabb, Michelle M; Batterman, Hollis J
2016-01-01
The Simplexa™ Group A Strep Direct assay is intended for use on the Integrated Cycler for detection of Group A Streptococcus (GAS) directly from throat swabs that have not undergone nucleic acid extraction. A prospective study of 1352 samples in 4 geographically diverse sites showed an overall prevalence of GAS of 15.4%. The assay demonstrated 97.4% sensitivity and 95.2% specificity versus culture. The positive predictive value compared to culture was 72.7%. However, 46 out of 57 discrepant samples were Group A Strep positive when tested using a bi-directional sequencing method illustrating the increased sensitivity of the assay compared to culture for detection of GAS. Rapid and accurate diagnosis of GAS allows for timely treatment to decrease complications of this prevalent organism that continues to cause substantial morbidity and mortality worldwide.
Raschke, Klaus; Pierce, Margaret; Popiela, Chu Chen
1976-01-01
The degree of stomatal sensitivity to CO2 was positively correlated with the content of abscisic acid of leaves of Xanthium strumarium grown in a greenhouse and then transferred for 24 hours or more to a cold (5/10 C, night/day) or a warm growth chamber (20/23 C). This correlation did not exist in plants kept in the greehouse continuously (high abscisic acid, no CO2 sensitivity), nor in plants transferred from the cold to the warm chamber (low abscisic acid, high CO2 sensitivity). The abscisic acid content of leaves was correlated with water content only within narrow limits, if at all. At equal water contents, prechilled leaves contained more abscisic acid than leaves of plants pretreated in the warm chamber. There appear to be at least two compartments for abscisic acid in the leaf. PMID:16659416
Raschke, K; Pierce, M; Popiela, C C
1976-01-01
The degree of stomatal sensitivity to CO(2) was positively correlated with the content of abscisic acid of leaves of Xanthium strumarium grown in a greenhouse and then transferred for 24 hours or more to a cold (5/10 C, night/day) or a warm growth chamber (20/23 C). This correlation did not exist in plants kept in the greehouse continuously (high abscisic acid, no CO(2) sensitivity), nor in plants transferred from the cold to the warm chamber (low abscisic acid, high CO(2) sensitivity). The abscisic acid content of leaves was correlated with water content only within narrow limits, if at all. At equal water contents, prechilled leaves contained more abscisic acid than leaves of plants pretreated in the warm chamber. There appear to be at least two compartments for abscisic acid in the leaf.
Platinum salt sensitivity in refinery workers: incidence and effects of smoking and exposure.
Calverley, A E; Rees, D; Dowdeswell, R J; Linnett, P J; Kielkowski, D
1995-01-01
OBJECTIVE--To measure the incidence of platinum salt sensitivity (PSS) in refinery workers and examine the influence of cigarette smoking and exposure to platinum salts on sensitisation. DESIGN--A prospective cohort study with examination of workers at quarterly intervals for 18 months, and again at 24 months. SETTING--A South African primary platinum refinery. SUBJECTS--78 new recruits, selected by the refinery's usual procedure, without apparent atopy and in good respiratory health. RESULTS--After 24 months 32 (41%) subjects had been diagnosed PSS and were subsequently medically separated. Twenty two (28%) cases were confirmed by positive skin prick test to platinum salts, 10 (13%) cases were symptomatic but skin prick negative. Incidence of cases per 100 person-months was 1.9 skin prick positive and 0.8 negative. Risk of sensitisation was about eight times greater for smokers than non-smokers, and six times greater for high exposure than low exposure. CONCLUSION--Smoking and intensity of exposure were definitely associated with development of PSS. Positive responses to platinum salt skin prick test had a 100% positive predictive value for symptoms and signs of PSS if exposure continued. PMID:7489056
Diagnostic value of isoproterenol testing in arrhythmogenic right ventricular cardiomyopathy.
Denis, Arnaud; Sacher, Frédéric; Derval, Nicolas; Lim, Han S; Cochet, Hubert; Shah, Ashok J; Daly, Matthew; Pillois, Xavier; Ramoul, Khaled; Komatsu, Yuki; Zemmoura, Adlane; Amraoui, Sana; Ritter, Philippe; Ploux, Sylvain; Bordachar, Pierre; Hocini, Mélèze; Jaïs, Pierre; Haïssaguerre, Michel
2014-08-01
Although the Task Force Criteria for arrhythmogenic right ventricular cardiomyopathy (ARVC) have recently been updated, the diagnosis remains challenging in the early stages. The aim of this study was to evaluate the diagnostic value of β-adrenergic stimulation in ARVC. We evaluated 412 consecutive patients (213 men, age 41.5±16 years) referred for premature ventricular contractions evaluation or suspected ARVC. Isoproterenol testing was performed with continuous infusion of isoproterenol (45 μg/min) for 3 minutes. It was considered positive if there were either (1) polymorphic premature ventricular contractions with ≥1 couplet or (2) sustained or nonsustained ventricular tachycardia with left bundle branch block excluding right ventricular outflow tract ventricular tachycardia. ARVC was diagnosed in 35 patients at initial evaluation (23 men, aged 42±15 years). Isoproterenol testing was positive in 32 of 35 (91.4%) patients with ARVC and in 42 of 377 (11.1%) patients without ARVC (P<0.0001). Sensitivity, specificity, positive, and negative predictive values of isoproterenol testing to diagnose ARVC were 91.4%, 88.9%, 43.2%, and 99.1%, respectively. During a mean follow-up period of 5.6±4.4 years, 6 additional patients met diagnostic criteria for ARVC. Importantly, initial isoproterenol testing was positive in 6 of 6 (100%) of these patients. Survival free from ARVC diagnosis was significantly lower in the positive isoproterenol group than in the negative isoproterenol group (P<0.0001, exact log-rank test). Ventricular arrhythmogenicity during isoproterenol testing is highly sensitive (sensitivity, 91.4%) for the diagnosis of ARVC, particularly in its early stages. © 2014 American Heart Association, Inc.
Werner, John S.; Elliott, Sarah L.; Choi, Stacey S.; Doble, Nathan
2009-01-01
PURPOSE To evaluate the influence of spherical aberration on contrast sensitivity using adaptive optics. SETTING Vision Science and Advanced Retinal Imaging Laboratory, Department of Ophthalmology & Vision Science, University of California, Davis Medical Center, Sacramento, California, USA. METHODS Contrast sensitivity at 8 cycles per degree was evaluated using an adaptive optics system that permitted aberrations to be measured with a Shack-Hartman wavefront sensor and controlled by a 109 actuator continuous-surface deformable mirror that was at a plane conjugate to the observer’s pupil. Vertical Gabor patches were viewed through a 6.3 mm diameter pupil conjugate aperture. Contrast sensitivity was measured with the deformable mirror set to produce 1 of 5 spherical aberration profiles (−0.2 to +0.2 μm). Contrast sensitivity over the range of spherical aberration was fitted with a polynomial function. RESULTS Three observers (age 21 to 24 years) participated. The measured total mean spherical aberration resulting from the spherical aberration profiles produced by the deformable mirror was between −0.15 μm and +0.25 μm. The peak contrast sensitivity of this function for the 3 observers combined occurred at +0.06 μm of spherical aberration. The peak contrast sensitivity was also achieved with positive spherical aberration for observer (mean 0.09). CONCLUSION There was intersubject variability in the measurements; however, the average visual performance was best with the introduction of a small positive spherical aberration. PMID:19545813
Malama, Eleni; Hoffmann-Köhler, Peggy; Biedermann, Insa; Koopmann, Regine; Krücken, Jürgen; Molina, José Manuel; Moreno, Alvaro Martinez; von Samson-Himmelstjerna, Georg; Sotiraki, Smaragda; Demeler, Janina
2014-10-01
Teladorsagia circumcincta is among the most important gastrointestinal parasites in small ruminants and the predominant species in Southern European goats. Parasite control is largely based on metaphylactic/preventative treatments, which is often seen as non-sustainable anymore. The reasons are increased consumer demand to reduce chemicals in livestock production and anthelmintic resistance against the common drugs. This study aimed at the development of a T. circumcincta-enzyme-linked immunosorbent assay (ELISA) specifically for goats. Samples were obtained from goats raised parasite-free or infected experimentally. Sampling continued during the following pasture season and housing period. The sensitivity for the use in bulk milk samples as an indicator of T. circumcincta infection levels in grazing goats was examined. The ELISA enables clear differentiation of negative and positive animals. With a specificity of 100% negative cut-off values for serum and milk were 0.294 and 0.228 (sensitivity, 95%). Positive cut-off values (sensitivity, 90%) were 0.606 (serum) and 0.419 (milk), while a sensitivity of 95% resulted in 0.509 and 0.363, respectively. The grey-zone between negative/positive cut-offs was introduced to deal with animals in pre-patency and decreasing antibody levels after infection. There was no cross reactivity for Trichostrongylus colubriformis and Cooperia oncophora while for Haemonchus contortus and Fasciola hepatica it cannot be fully excluded currently. In bulk milk samples, 5% of the milk had to be contributed from animals infected with T. circumcincta to be detected as positive. The results derived from experimentally and naturally infected as well as parasite naïve animals indicate the potential of the ELISA to be used in targeted anthelmintic treatment regimes in goats.
Salinas, María; Flores, Emilio; López-Garrigós, Maite; Díaz, Elena; Esteban, Patricia; Leiva-Salinas, Carlos
2017-01-01
To apply a continual improvement model to develop an algorithm for ordering laboratory tests to diagnose acute pancreatitis in a hospital emergency department. Quasi-experimental study using the continual improvement model (plan, do, check, adjust cycles) in 2 consecutive phases in emergency patients: amylase and lipase results were used to diagnose acute pancreatitis in the first phase; in the second, only lipase level was first determined; amylase testing was then ordered only if the lipase level fell within a certain range. We collected demographic data, number amylase and lipase tests ordered and the findings, final diagnosis, and the results of a questionnaire to evaluate satisfaction with emergency care. The first phase included 517 patients, of whom 20 had acute pancreatitis. For amylase testing sensitivity was 0.70; specificity, 0.85; positive predictive value (PPV), 17; and negative predictive value (NPV), 0.31. For lipase testing these values were sensitivity, 0.85; specificity, 0.96; PPV, 21, and NPV, 0.16. When both tests were done, sensitivity was 0.85; specificity 0.99; PPV, 85; and NPV, 0.15. The second phase included data for 4815 patients, 118 of whom had acute pancreatitis. The measures of diagnostic yield for the new algorithm were sensitivity, 0.92; specificity, 0.98; PPV, 46; and NPV, 0.08]. This study demonstrates a process for developing a protocol to guide laboratory testing in acute pancreatitis in the hospital emergency department. The proposed sequence of testing for pancreatic enzyme levels can be effective for diagnosing acute pancreatitis in patients with abdominal pain.
Should gram stains have a role in diagnosing hip arthroplasty infections?
Johnson, Aaron J; Zywiel, Michael G; Stroh, D Alex; Marker, David R; Mont, Michael A
2010-09-01
The utility of Gram stains in diagnosing periprosthetic infections following total hip arthroplasty has recently been questioned. Several studies report low sensitivity of the test, and its poor ability to either confirm or rule out infection in patients undergoing revision total hip arthroplasty. Despite this, many institutions including that of the senior author continue to perform Gram stains during revision total hip arthroplasty. We assessed the sensitivity, specificity, accuracy, and positive and negative predictive values of Gram stains from surgical-site samplings taken from procedures on patients with both infected and aseptic revision total hip arthroplasties. A review was performed on patients who underwent revision total hip arthroplasty between 2000 and 2007. Eighty-two Gram stains were performed on patients who had infected total hip arthroplasties and underwent revision procedures. Additionally, of the 410 revision total hip arthroplasties performed on patients who were confirmed infection-free, 120 Gram stains were performed. Patients were diagnosed as infected using multiple criteria at the time of surgery. Sensitivity, specificity, positive and negative predictive values, and accuracy were calculated from these Gram stain results. The Gram stain demonstrated a sensitivity and specificity of 9.8% and 100%, respectively. In this series, the Gram stain had a negative predictive value of 62%, a positive predictive value of 100%, and an accuracy of 63%. Gram stains obtained from surgical-site samples had poor sensitivity and poor negative predictive value. Based on these findings, as well as those of other authors, we believe that Gram stains should no longer be considered for diagnosing infections in revision total hip arthroplasty. Level III, diagnostic study. See Guidelines for Authors for a complete description of levels of evidence.
NASA Technical Reports Server (NTRS)
Maniotis, A. J.; Bojanowski, K.; Ingber, D. E.
1997-01-01
Chromatin is thought to be structurally discontinuous because it is packaged into morphologically distinct chromosomes that appear physically isolated from one another in metaphase preparations used for cytogenetic studies. However, analysis of chromosome positioning and movement suggest that different chromosomes often behave as if they were physically connected in interphase as well as mitosis. To address this paradox directly, we used a microsurgical technique to physically remove nucleoplasm or chromosomes from living cells under isotonic conditions. Using this approach, we found that pulling a single nucleolus or chromosome out from interphase or mitotic cells resulted in sequential removal of the remaining nucleoli and chromosomes, interconnected by a continuous elastic thread. Enzymatic treatments of interphase nucleoplasm and chromosome chains held under tension revealed that mechanical continuity within the chromatin was mediated by elements sensitive to DNase or micrococcal nuclease, but not RNases, formamide at high temperature, or proteases. In contrast, mechanical coupling between mitotic chromosomes and the surrounding cytoplasm appeared to be mediated by gelsolin-sensitive microfilaments. Furthermore, when ion concentrations were raised and lowered, both the chromosomes and the interconnecting strands underwent multiple rounds of decondensation and recondensation. As a result of these dynamic structural alterations, the mitotic chains also became sensitive to disruption by restriction enzymes. Ion-induced chromosome decondensation could be blocked by treatment with DNA binding dyes, agents that reduce protein disulfide linkages within nuclear matrix, or an antibody directed against histones. Fully decondensed chromatin strands also could be induced to recondense into chromosomes with pre-existing size, shape, number, and position by adding anti-histone antibodies. Conversely, removal of histones by proteolysis or heparin treatment produced chromosome decondensation which could be reversed by addition of histone H1, but not histones H2b or H3. These data suggest that DNA, its associated protein scaffolds, and surrounding cytoskeletal networks function as a structurally-unified system. Mechanical coupling within the nucleoplasm may coordinate dynamic alterations in chromatin structure, guide chromosome movement, and ensure fidelity of mitosis.
Evaluation of musculoskeletal sepsis with indium-111 white blood cell imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ouzounian, T.J.; Thompson, L.; Grogan, T.J.
The detection of musculoskeletal sepsis, especially following joint replacement, continues to be a challenging problem. Often, even with invasive diagnostic evaluation, the diagnosis of infection remains uncertain. This is a report on the first 55 Indium-111 white blood cell (WBC) images performed in 39 patients for the evaluation of musculoskeletal sepsis. There were 40 negative and 15 positive Indium-111 WBC images. These were correlated with operative culture and tissue pathology, aspiration culture, and clinical findings. Thirty-eight images were performed for the evaluation of possible total joint sepsis (8 positive and 30 negative images); 17 for the evaluation of nonarthroplasty-related musculoskeletalmore » sepsis (7 positive and 10 negative images). Overall, there were 13 true-positive, 39 true-negative, two false-positive, and one false-negative images. Indium-111 WBC imaging is a sensitive and specific means of evaluating musculoskeletal sepsis, especially following total joint replacement.« less
Korenblit, Jason; Tholey, Danielle M.; Tolin, Joanna; Loren, David; Kowalski, Thomas; Adler, Douglas G.; Davolos, Julie; Siddiqui, Ali A.
2016-01-01
Background and Objectives: Recent reports have indicated that the time of day may impact the detection rate of abnormal cytology on gynecologic cytology samples. The aim of this study was to determine if procedure time or queue position affected the performance characteristics of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) for diagnosing solid pancreatic malignancies. Patients and Methods: We conducted a retrospective study evaluating patients with solid pancreatic lesions in whom EUS-FNA was performed. Three timing variables were evaluated as surrogate markers for endoscopist fatigue: Procedure start times, morning versus afternoon procedures, and endoscopy queue position. Statistical analyses were performed to determine whether the timing variables predicted performance characteristics of EUS-FNA. Results: We identified 609 patients (mean age: 65.8 years, 52.1% males) with solid pancreatic lesions who underwent EUS-FNA. The sensitivity of EUS-FNA was 100% for procedures that started at 7 AM while cases that started at 4 PM had a sensitivity of 81%. Using start time on a continuous scale, each elapsed hour was associated with a 1.9% decrease in EUS-FNA sensitivity (P = 0.003). Similarly, a 10% reduction in EUS-FNA sensitivity was detected between morning and afternoon procedures (92% vs. 82% respectively, P = 0.0006). A linear regression comparing the procedure start time and diagnostic accuracy revealed a decrease of approximately 1.7% in procedure accuracy for every hour later a procedure was started. A 16% reduction in EUS-FNA accuracy was detected between morning and afternoon procedures (100% vs. 84% respectively, P = 0.0009). When the queue position was assessed, a 2.4% reduction in accuracy was noted for each increase in the queue position (P = 0.013). Conclusion: Sensitivity and diagnostic accuracy of EUS-FNA for solid pancreatic lesions decline with progressively later EUS starting times and increasing numbers of procedures before a given EUS, potentially from endoscopist fatigue and cytotechnologist fatigue. PMID:27080605
Continuous-energy eigenvalue sensitivity coefficient calculations in TSUNAMI-3D
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perfetti, C. M.; Rearden, B. T.
2013-07-01
Two methods for calculating eigenvalue sensitivity coefficients in continuous-energy Monte Carlo applications were implemented in the KENO code within the SCALE code package. The methods were used to calculate sensitivity coefficients for several test problems and produced sensitivity coefficients that agreed well with both reference sensitivities and multigroup TSUNAMI-3D sensitivity coefficients. The newly developed CLUTCH method was observed to produce sensitivity coefficients with high figures of merit and a low memory footprint, and both continuous-energy sensitivity methods met or exceeded the accuracy of the multigroup TSUNAMI-3D calculations. (authors)
Development of a SCALE Tool for Continuous-Energy Eigenvalue Sensitivity Coefficient Calculations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perfetti, Christopher M; Rearden, Bradley T
2013-01-01
Two methods for calculating eigenvalue sensitivity coefficients in continuous-energy Monte Carlo applications were implemented in the KENO code within the SCALE code package. The methods were used to calculate sensitivity coefficients for several criticality safety problems and produced sensitivity coefficients that agreed well with both reference sensitivities and multigroup TSUNAMI-3D sensitivity coefficients. The newly developed CLUTCH method was observed to produce sensitivity coefficients with high figures of merit and low memory requirements, and both continuous-energy sensitivity methods met or exceeded the accuracy of the multigroup TSUNAMI-3D calculations.
Effects of Aluminum Stress on Protective Enzyme Activity in Tie Guanyin leaves
NASA Astrophysics Data System (ADS)
Sun, JingWei; Du, NaiChen; Zhang, YunFeng
2018-01-01
The experiment was adopted to study the change of SOD, CAT and POD activity of Tie guanyin (new leaf and old leaf blade of different concentrations of aluminum stress; in this paper, 0 (CK), 40, 200, four gradients of 400mg/L concentration of Al3+ in acidic conditions, Tieguanyin tea leaf SOD, cat and POD activity changes. The results showed that high concentrations of aluminum stress on antioxidant enzyme system activity cannot continue to increase; at the same time showed that SOD is sensitive to aluminum toxicity concentration change, its sensitivity is higher than CAT and POD, SOD and CAT activity and the aging and decline of plant There was a positive correlation.
Three-dimensional engineered heart tissue from neonatal rat cardiac myocytes.
Zimmermann, W H; Fink, C; Kralisch, D; Remmers, U; Weil, J; Eschenhagen, T
2000-04-05
A technique is presented that allows neonatal rat cardiac myocytes to form spontaneously and coherently beating 3-dimensional engineered heart tissue (EHT) in vitro, either as a plane biconcaval matrix anchored at both sides on Velcro-coated silicone tubes or as a ring. Contractile activity was monitored in standard organ baths or continuously in a CO(2) incubator for up to 18 days (=26 days after casting). Long-term measurements showed an increase in force between days 8 and 18 after casting and stable forces thereafter. At day 10, the twitch amplitude (TA) of electrically paced EHTs (average length x width x thickness, 11 x 6 x 0.4 mm) was 0.51 mN at length of maximal force development (L(max)) and a maximally effective calcium concentration. EHTs showed typical features of neonatal rat heart: a positive force-length and a negative force-frequency relation, high sensitivity to calcium (EC(50) 0.24 mM), modest positive inotropic (increase in TA by 46%) and pronounced positive lusitropic effect of isoprenaline (decrease in twitch duration by 21%). Both effects of isoprenaline were sensitive to the muscarinic receptor agonist carbachol in a pertussis toxin-sensitive manner. Adenovirus-mediated gene transfer of beta-galactosidase into EHTs reached 100% efficiency. In summary, EHTs retain many of the physiological characteristics of rat cardiac tissue and allow efficient gene transfer with subsequent force measurement. Copyright 2000 John Wiley & Sons, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1999-06-01
The Shonka Research Associates, Inc. Position-Sensitive Radiation Monitor both detects surface radiation and prepares electronic survey map/survey report of surveyed area automatically. The electronically recorded map can be downloaded to a personal computer for review and a map/report can be generated for inclusion in work packages. Switching from beta-gamma detection to alpha detection is relatively simple and entails moving a switch position to alpha and adjusting the voltage level to an alpha detection level. No field calibration is required when switching from beta-gamma to alpha detection. The system can be used for free-release surveys because it meets the federal detectionmore » level sensitivity limits requires for surface survey instrumentation. This technology is superior to traditionally-used floor contamination monitor (FCM) and hand-held survey instrumentation because it can precisely register locations of radioactivity and accurately correlate contamination levels to specific locations. Additionally, it can collect and store continuous radiological data in database format, which can be used to produce real-time imagery as well as automated graphics of survey data. Its flexible design can accommodate a variety of detectors. The cost of the innovative technology is 13% to 57% lower than traditional methods. This technology is suited for radiological surveys of flat surfaces at US Department of Energy (DOE) nuclear facility decontamination and decommissioning (D and D) sites or similar public or commercial sites.« less
Laboratory audit as part of the quality assessment of a primary HPV-screening program.
Hortlund, Maria; Sundström, Karin; Lamin, Helena; Hjerpe, Anders; Dillner, Joakim
2016-02-01
As primary HPV screening programs are rolled out, methods are needed for routine quality assurance of HPV laboratory analyzes. To explore the use of similar design for audit as currently used in cytology-based screening, to estimate the clinical sensitivity to identify women at risk for CIN 3 or worse (CIN3+). Population-based cohort study conducted within the cervical screening program in Stockholm, Sweden, in 2011-2012. All women with histopathologically confirmed CIN3+ in the following two years were identified by registry analysis. Primary HPV and cytology screening results were collected. For women who had not been HPV tested, biobanked cytology samples were HPV-tested. If the original HPV result had been negative, the sample and subsequent biopsies were analyzed with broad HPV typing (general primer PCR and Luminex). 154 women had a biobanked prediagnostic cytology sample taken up to 2 years before a histopathologically confirmed CIN3+. The high-risk HPV-positivity was 97% (148/154 women), whereas 143/154 (94%) women had had a cytological abnormality. Among the six HPV-negative samples, one sample was HPV 33 positive in repeat testing whereas the other five cases were HPV-negative also on repeat testing, but HPV-positive in the subsequent tumor tissue. A sensitivity of the HPV test that is higher than the sensitivity of cytology suggests adequate quality of the testing. Regular audits of clinical sensitivity, similar to those of cytology-based screening, should be used also in HPV-based screening programs, in order to continuously monitor the performance of the analyzes. Copyright © 2015 Elsevier B.V. All rights reserved.
Fan, Xiao-Yong; Lü, Guo-Zhen; Wu, Li-Na; Chen, Jing-Hua; Xu, Wen-Qing; Zhao, Chun-Nü; Guo, Sheng-Qi
2006-12-01
Current regulations and recommendations proposed for the production of vaccines in continuous cell lines of any origin demand that these be free of exogenous viruses, particularly retroviruses. Recently, the ultra-sensitive product-enhanced reverse transcriptase (PERT) assay can be used to detect minute of reverse transcriptase (RTase) in single retroviral particle and is 10(6) times more sensitive than the conventional RTase assays. However, coincidental with this increase in sensitivity is an increase in false-positive reactions derived from contaminating cellular DNA polymerases, which are known to have RTase-like activities. To develop a modified single-tube one-step PERT (mSTOS-PERT) assay with improvements on decreasing significantly the level of false-positive reactions, and to evaluate the mSTOS-PERT assay for sensitivity and specificity. Ampliwaxtrade mark was used to compartmentalize the reverse transcription (RT) and PCR step in the same micro-tube with more efficiency and reproducibility, while maintaining the high sensitivity. The DNA amplification products were separated by 2% agarose gel electrophoresis, and then analyzed by non-isotopic Southern blot hybridization. A wide variety of cell lines used in biologicals production were detected to validate the improved mSTOS-PERT assay. The detection limit for the mSTOS-PERT assay was at least 10(-9)U, when using AMV-RTase as a positive control. Furthermore, heparin involvement in the RT step can eliminate completely the false-positive PERT signals which are exhibited by cellular polymerases such as DNA-dependent DNA polymerase alpha, gamma released by cell death. Most mammalian cells (MRC-5, Vero, WISH, 2BS, RK-13, MDCK, etc.) are PERT-negative in cell supernatants. Some PERT-positive signals in cell lysates were found to be introduced by the cellular DNA polymerases and could be inhibited specifically by heparin. Chick cells derived from either chick embryo fibroblasts (CEF) or allantoic fluid from SPF embryonated eggs, murine hybridoma cell SP2/0, etc., contained authentic RTase activities, which could not be inactivated by heparin. The improved mSTOS-PERT assay described here may distinguish the genuine RTase activity from cellular polymerases with high sensitivity and specificity, and is rapid and easy to perform to screen for the possible contamination of minute retroviruses in the cell substrates used in vaccine production.
Jensen, Morten Hasselstrøm; Christensen, Toke Folke; Tarnow, Lise; Seto, Edmund; Dencker Johansen, Mette; Hejlesen, Ole Kristian
2013-07-01
Hypoglycemia is a potentially fatal condition. Continuous glucose monitoring (CGM) has the potential to detect hypoglycemia in real time and thereby reduce time in hypoglycemia and avoid any further decline in blood glucose level. However, CGM is inaccurate and shows a substantial number of cases in which the hypoglycemic event is not detected by the CGM. The aim of this study was to develop a pattern classification model to optimize real-time hypoglycemia detection. Features such as time since last insulin injection and linear regression, kurtosis, and skewness of the CGM signal in different time intervals were extracted from data of 10 male subjects experiencing 17 insulin-induced hypoglycemic events in an experimental setting. Nondiscriminative features were eliminated with SEPCOR and forward selection. The feature combinations were used in a Support Vector Machine model and the performance assessed by sample-based sensitivity and specificity and event-based sensitivity and number of false-positives. The best model was composed by using seven features and was able to detect 17 of 17 hypoglycemic events with one false-positive compared with 12 of 17 hypoglycemic events with zero false-positives for the CGM alone. Lead-time was 14 min and 0 min for the model and the CGM alone, respectively. This optimized real-time hypoglycemia detection provides a unique approach for the diabetes patient to reduce time in hypoglycemia and learn about patterns in glucose excursions. Although these results are promising, the model needs to be validated on CGM data from patients with spontaneous hypoglycemic events.
Kim, Si Hyun; Jeong, Haeng Soon; Kim, Yeong Hoon; Song, Sae Am; Lee, Ja Young; Oh, Seung Hwan; Kim, Hye Ran; Lee, Jeong Nyeo; Kho, Weon-Gyu; Shin, Jeong Hwan
2012-03-01
The aims of this study were to compare several DNA extraction methods and 16S rDNA primers and to evaluate the clinical utility of broad-range PCR in continuous ambulatory peritoneal dialysis (CAPD) culture fluids. Six type strains were used as model organisms in dilutions from 10(8) to 10(0) colony-forming units (CFU)/mL for the evaluation of 5 DNA extraction methods and 5 PCR primer pairs. Broad-range PCR was applied to 100 CAPD culture fluids, and the results were compared with conventional culture results. There were some differences between the various DNA extraction methods and primer sets with regard to the detection limits. The InstaGene Matrix (Bio-Rad Laboratories, USA) and Exgene Clinic SV kits (GeneAll Biotechnology Co. Ltd, Korea) seem to have higher sensitivities than the others. The results of broad-range PCR were concordant with the results from culture in 97% of all cases (97/100). Two culture-positive cases that were broad-range PCR-negative were identified as Candida albicans, and 1 PCR-positive but culture-negative sample was identified as Bacillus circulans by sequencing. Two samples among 54 broad-range PCR-positive products could not be sequenced. There were differences in the analytical sensitivity of various DNA extraction methods and primers for broad-range PCR. The broad-range PCR assay can be used to detect bacterial pathogens in CAPD culture fluid as a supplement to culture methods.
Agnello, Luisa; Bivona, Giulia; Novo, Giuseppina; Scazzone, Concetta; Muratore, Roberto; Levantino, Piero; Bellia, Chiara; Lo Sasso, Bruna; Ciaccio, Marcello
2017-10-01
Early detecting AMI in individuals presenting to the ED with chest pain continues to be a challenge. cTn is the gold standard for AMI diagnosis but early presenters (<1 hours from symptom onset) maybe cTn negative on admission. We analysed the diagnostic value of h-FABP and hs-TnI in patients presenting to ED with chest pain and no cTnI elevations. 28 AMI and 28 no-AMI individuals both presented to ED within one hour from pain onset were included. Blood donors were analysed for h-FABP cut-off identification. Among AMI patients, 55% were positive for h-FABP and 34.6% were positive for hs-TnI (p = .015), thus 21% were positive only for h-FABP. The diagnostic accuracy was assessed by ROC curve. h-FABP showed a higher sensitivity but lower specificity than hs-TnI. In our study, the frequency of h-FABP positivity among AMI patients was higher than that of hs-TnI, which would have missed six of them; however, hs-TnI AUC was superior to that of h-FABP. These preliminary findings might confirm that h-FABP may be a good candidate for AMI rule-in/rule-out within the ED context.
Liking, wanting, and the incentive-sensitization theory of addiction.
Berridge, Kent C; Robinson, Terry E
2016-11-01
Rewards are both "liked" and "wanted," and those 2 words seem almost interchangeable. However, the brain circuitry that mediates the psychological process of "wanting" a particular reward is dissociable from circuitry that mediates the degree to which it is "liked." Incentive salience or "wanting," a form of motivation, is generated by large and robust neural systems that include mesolimbic dopamine. By comparison, "liking," or the actual pleasurable impact of reward consumption, is mediated by smaller and fragile neural systems, and is not dependent on dopamine. The incentive-sensitization theory posits the essence of drug addiction to be excessive amplification specifically of psychological "wanting," especially triggered by cues, without necessarily an amplification of "liking." This is because of long-lasting changes in dopamine-related motivation systems of susceptible individuals, called "neural sensitization." A quarter-century after its proposal, evidence has continued to grow in support the incentive-sensitization theory. Further, its scope is now expanding to include diverse behavioral addictions and other psychopathologies. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Liking, Wanting and the Incentive-Sensitization Theory of Addiction
Berridge, Kent C.; Robinson, Terry E.
2016-01-01
Rewards are both ‘liked’ and ‘wanted’, and those two words seem almost interchangeable. However, the brain circuitry that mediates the psychological process of ‘wanting’ a particular reward is dissociable from circuitry that mediates the degree to which it is ‘liked’. Incentive salience or ‘wanting’, a form of motivation, is generated by large and robust neural systems that include mesolimbic dopamine. By comparison, ‘liking’, or the actual pleasurable impact of reward consumption, is mediated by smaller and fragile neural systems, and is not dependent on dopamine. The incentive-sensitization theory posits the essence of drug addiction to be excessive amplification specifically of psychological ‘wanting’, especially triggered by cues, without necessarily an amplification of ‘liking’. This is due to long-lasting changes in dopamine-related motivation systems of susceptible individuals, called neural sensitization. A quarter-century after its proposal, evidence has continued to grow in support the incentive-sensitization theory. Further, its scope is now expanding to include diverse behavioral addictions and other psychopathologies. PMID:27977239
The scotopic threshold response of the dark-adapted electroretinogram of the mouse.
Saszik, Shannon M; Robson, John G; Frishman, Laura J
2002-09-15
The most sensitive response in the dark-adapted electroretinogram (ERG), the scotopic threshold response (STR) which originates from the proximal retina, has been identified in several mammals including humans, but previously not in the mouse. The current study established the presence and assessed the nature of the mouse STR. ERGs were recorded from adult wild-type C57/BL6 mice anaesthetized with ketamine (70 mg kg(-1)) and xylazine (7 mg kg(-1)). Recordings were between DTL fibres placed under contact lenses on the two eyes. Monocular test stimuli were brief flashes (lambda(max) 462 nm; -6.1 to +1.8 log scotopic Troland seconds(sc td s)) under fully dark-adapted conditions and in the presence of steady adapting backgrounds (-3.2 to -1.7 log sc td). For the weakest test stimuli, ERGs consisted of a slow negative potential maximal approximately 200 ms after the flash, with a small positive potential preceding it. The negative wave resembled the STR of other species. As intensity was increased, the negative potential saturated but the positive potential (maximal approximately 110 ms) continued to grow as the b-wave. For stimuli that saturated the b-wave, the a-wave emerged. For stimulus strengths up to those at which the a-wave emerged, ERG amplitudes measured at fixed times after the flash (110 and 200 ms) were fitted with a model assuming an initially linear rise of response amplitude with intensity, followed by saturation of five components of declining sensitivity: a negative STR (nSTR), a positive STR (pSTR), a positive scotopic response (pSR), PII (the bipolar cell component) and PIII (the photoreceptor component). The nSTR and pSTR were approximately 3 times more sensitive than the pSR, which was approximately 7 times more sensitive than PII. The sensitive positive components dominated the b-wave up to > 5 % of its saturated amplitude. Pharmacological agents that suppress proximal retinal activity (e.g. GABA) minimized the pSTR, nSTR and pSR, essentially isolating PII which rose linearly with intensity before showing hyperbolic saturation. The nSTR, pSTR and pSR were desensitized by weaker backgrounds than those desensitizing PII. In conclusion, ERG components of proximal retinal origin that are more sensitive to test flashes and adapting backgrounds than PII provide the 'threshold' negative and positive (b-wave) responses of the mouse dark-adapted ERG. These results support the use of the mouse ERG in studies of proximal retinal function.
Periprosthetic infection: where do we stand with regard to Gram stain?
Ghanem, Elie; Ketonis, Constantinos; Restrepo, Camilo; Joshi, Ashish; Barrack, Robert; Parvizi, Javad
2009-02-01
One of the routinely used intraoperative tests for diagnosis of periprosthetic infection (PPI) is the Gram stain. It is not known if the result of this test can vary according to the type of joint affected or the number of specimen samples collected. We examined the role of this diagnostic test in a large cohort of patients from a single institution. A positive gram stain was defined as the visualization of bacterial cells or "many neutrophils" (> 5 per high-power field) in the smear. The sensitivity, specificity, and predictive values of each individual diagnostic arm of Gram stain were determined. Combinations were performed in series, which required both tests to be positive to confirm infection, and also in parallel, which necessitated both tests to be negative to rule out infection. The presence of organisms and "many" neutrophils on a Gram smear had high specificity (98-100%) and positive predictive value (89-100%) in both THA and TKA. The sensitivities (30-50%) and negative predictive values (70-79%) of the 2 tests were low for both joint types. When the 2 tests were combined in series, the specificity and positive predictive value were absolute (100%). The sensitivity and the negative predictive value improved for both THA and TKA (43-64% and 82%, respectively). Although the 2 diagnostic arms of Gram staining can be combined to achieve improved negative predictive value (82%), Gram stain continues to have little value in ruling out PPI. With the advances in the field of molecular biology, novel diagnostic modalities need to be designed that can replace these traditional and poor tests.
Hubble, Michael W; Richards, Michael E; Wilfong, Denise A
2008-01-01
To estimate the cost-effectiveness of continuous positive airway pressure (CPAP) in managing prehospital acute pulmonary edema in an urban EMS system. Using estimates from published reports on prehospital and emergency department CPAP, a cost-effectiveness model of implementing CPAP in a typical urban EMS system was derived from the societal perspective as well as the perspective of the implementing EMS system. To assess the robustness of the model, a series of univariate and multivariate sensitivity analyses was performed on the input variables. The cost of consumables, equipment, and training yielded a total cost of $89 per CPAP application. The theoretical system would be expected to use CPAP 4 times per 1000 EMS patients and is expected to save 0.75 additional lives per 1000 EMS patients at a cost of $490 per life saved. CPAP is also expected to result in approximately one less intubation per 6 CPAP applications and reduce hospitalization costs by $4075 per year for each CPAP application. Through sensitivity analyses the model was verified to be robust across a wide range of input variable assumptions. Previous studies have demonstrated the clinical effectiveness of CPAP in the management of acute pulmonary edema. Through a theoretical analysis which modeled the costs and clinical benefits of implementing CPAP in an urban EMS system, prehospital CPAP appears to be a cost-effective treatment.
NASA Astrophysics Data System (ADS)
Krejci, F.; Zemlicka, J.; Jakubek, J.; Dudak, J.; Vavrik, D.; Köster, U.; Atkins, D.; Kaestner, A.; Soltes, J.; Viererbl, L.; Vacik, J.; Tomandl, I.
2016-12-01
Using a suitable isotope such as 6Li and 10B semiconductor hybrid pixel detectors can be successfully adapted for position sensitive detection of thermal and cold neutrons via conversion into energetic light ions. The adapted devices then typically provides spatial resolution at the level comparable to the pixel pitch (55 μm) and sensitive area of about few cm2. In this contribution, we describe further progress in neutron imaging performance based on the development of a large-area hybrid pixel detector providing practically continuous neutron sensitive area of 71 × 57 mm2. The measurements characterising the detector performance at the cold neutron imaging instrument ICON at PSI and high-flux imaging beam-line Neutrograph at ILL are presented. At both facilities, high-resolution high-contrast neutron radiography with the newly developed detector has been successfully applied for objects which imaging were previously difficult with hybrid pixel technology (such as various composite materials, objects of cultural heritage etc.). Further, a significant improvement in the spatial resolution of neutron radiography with hybrid semiconductor pixel detector based on the fast read-out Timepix-based detector is presented. The system is equipped with a thin planar 6LiF convertor operated effectively in the event-by-event mode enabling position sensitive detection with spatial resolution better than 10 μm.
Evaluation of continuous air monitor placement in a plutonium facility.
Whicker, J J; Rodgers, J C; Fairchild, C I; Scripsick, R C; Lopez, R C
1997-05-01
Department of Energy appraisers found continuous air monitors at Department of Energy plutonium facilities alarmed less than 30% of the time when integrated room plutonium air concentrations exceeded 500 DAC-hours. Without other interventions, this alarm percentage suggests the possibility that workers could be exposed to high airborne concentrations without continuous air monitor alarms. Past research has shown that placement of continuous air monitors is a critical component in rapid and reliable detection of airborne releases. At Los Alamos National Laboratory and many other Department of Energy plutonium facilities, continuous air monitors have been primarily placed at ventilation exhaust points. The purpose of this study was to evaluate and compare the effectiveness of exhaust register placement of workplace continuous air monitors with other sampling locations. Polydisperse oil aerosols were released from multiple locations in two plutonium laboratories at Los Alamos National Laboratory. An array of laser particle counters positioned in the rooms measured time-resolved aerosol dispersion. Results showed alternative placement of air samplers generally resulted in aerosol detection that was faster, often more sensitive, and equally reliable compared with samplers at exhaust registers.
Unannounced Meals in the Artificial Pancreas: Detection Using Continuous Glucose Monitoring
Herrero, Pau; Bondia, Jorge
2018-01-01
The artificial pancreas (AP) system is designed to regulate blood glucose in subjects with type 1 diabetes using a continuous glucose monitor informed controller that adjusts insulin infusion via an insulin pump. However, current AP developments are mainly hybrid closed-loop systems that include feed-forward actions triggered by the announcement of meals or exercise. The first step to fully closing the loop in the AP requires removing meal announcement, which is currently the most effective way to alleviate postprandial hyperglycemia due to the delay in insulin action. Here, a novel approach to meal detection in the AP is presented using a sliding window and computing the normalized cross-covariance between measured glucose and the forward difference of a disturbance term, estimated from an augmented minimal model using an Unscented Kalman Filter. Three different tunings were applied to the same meal detection algorithm: (1) a high sensitivity tuning, (2) a trade-off tuning that has a high amount of meals detected and a low amount of false positives (FP), and (3) a low FP tuning. For the three tunings sensitivities 99 ± 2%, 93 ± 5%, and 47 ± 12% were achieved, respectively. A sensitivity analysis was also performed and found that higher carbohydrate quantities and faster rates of glucose appearance result in favorable meal detection outcomes. PMID:29547553
Prenatal diagnosis using polymerase chain reaction on amniotic fluid for congenital toxoplasmosis.
Romand, S; Wallon, M; Franck, J; Thulliez, P; Peyron, F; Dumon, H
2001-02-01
To evaluate sensitivity, specificity, and predictive values of a prenatal amniotic fluid (AF) polymerase chain reaction (PCR) test for diagnosis of congenital toxoplasmosis. A multicenter prospective study was done on 271 women with proved primary Toxoplasma infection during pregnancy and who had amniocentesis for prenatal diagnosis by PCR. Live-born infants were eligible for analysis only if a serologic follow-up could assess a definitive infection status. Of the 270 evaluable cases, 75 were congenitally infected, 48 of whom had a positive PCR at prenatal diagnosis. Overall sensitivity of PCR on AF was estimated at 64% (95% confidence interval [CI] 53.1%, 74.9%), negative predictive value of 87.8% (95% CI 83.5%, 92.1%), whereas specificity and positive predictive value were 100% (95% CIs 98%, 100% and 92.3%, 100%, respectively). Among cases with congenital toxoplasmosis, there were no significant differences between those with positive or negative PCR with regard to median gestational age at maternal infection, interval between maternal infection and amniocentesis, or duration of treatment before amniocentesis. However, sensitivity of PCR was found to be significantly higher for maternal infections that occurred between 17 and 21 weeks' gestation (P <.02). A negative PCR of AF cannot rule out congenital infection. In this case, continuation of treatment with spiramycin combined with ultrasonographic follow-up and postnatal follow-up are warranted. Our results also suggest presumptive treatment combining pyrimethamine and sulfonamides in case of maternal infection occurring late in pregnancy.
Lionetti, Francesca; Aron, Arthur; Aron, Elaine N; Burns, G Leonard; Jagiellowicz, Jadzia; Pluess, Michael
2018-01-22
According to empirical studies and recent theories, people differ substantially in their reactivity or sensitivity to environmental influences with some being generally more affected than others. More sensitive individuals have been described as orchids and less-sensitive ones as dandelions. Applying a data-driven approach, we explored the existence of sensitivity groups in a sample of 906 adults who completed the highly sensitive person (HSP) scale. According to factor analyses, the HSP scale reflects a bifactor model with a general sensitivity factor. In contrast to prevailing theories, latent class analyses consistently suggested the existence of three rather than two groups. While we were able to identify a highly sensitive (orchids, 31%) and a low-sensitive group (dandelions, 29%), we also detected a third group (40%) characterised by medium sensitivity, which we refer to as tulips in keeping with the flower metaphor. Preliminary cut-off scores for all three groups are provided. In order to characterise the different sensitivity groups, we investigated group differences regarding the Big Five personality traits, as well as experimentally assessed emotional reactivity in an additional independent sample. According to these follow-up analyses, the three groups differed in neuroticism, extraversion and emotional reactivity to positive mood induction with orchids scoring significantly higher in neuroticism and emotional reactivity and lower in extraversion than the other two groups (dandelions also differed significantly from tulips). Findings suggest that environmental sensitivity is a continuous and normally distributed trait but that people fall into three distinct sensitive groups along a sensitivity continuum.
Improving sensitivity in micro-free flow electrophoresis using signal averaging
Turgeon, Ryan T.; Bowser, Michael T.
2009-01-01
Microfluidic free-flow electrophoresis (μFFE) is a separation technique that separates continuous streams of analytes as they travel through an electric field in a planar flow channel. The continuous nature of the μFFE separation suggests that approaches more commonly applied in spectroscopy and imaging may be effective in improving sensitivity. The current paper describes the S/N improvements that can be achieved by simply averaging multiple images of a μFFE separation; 20–24-fold improvements in S/N were observed by averaging the signal from 500 images recorded for over 2 min. Up to an 80-fold improvement in S/N was observed by averaging 6500 images. Detection limits as low as 14 pM were achieved for fluorescein, which is impressive considering the non-ideal optical set-up used in these experiments. The limitation to this signal averaging approach was the stability of the μFFE separation. At separation times longer than 20 min bubbles began to form at the electrodes, which disrupted the flow profile through the device, giving rise to erratic peak positions. PMID:19319908
Miedaner, Felix; Allendorf, Antje; Kuntz, Ludwig; Woopen, Christiane; Roth, Bernhard
2016-05-01
To assess the association between nursing team continuity and quality of care. Research on nurse staffing and its effect on quality of care is investigated to different degrees. However, very few studies have observed whether the continuous deployment of nursing staff is associated with quality of care. This study was conducted in two university neonatal intensive care units (NICUs). We matched nurse schedule data for the NICUs with nursing-sensitive patient outcomes and quality of care, as perceived by parents. We used analysis of variance to analyse differences in nursing team continuity between NICUs and regression analyses to identify associations with the outcome measures. There were considerable differences between units in terms of team continuity of nursing staff. Positive associations were found between team continuity and a higher rate of non-invasive respiratory support as well as parents' perceptions of how well they knew their nurse. The findings show remarkable differences in staff assignment in the different NICUs. In addition to appropriate staffing levels, scheduling nursing teams continuously would appear to play a role in influencing treatment quality. This paper emphasises the importance of carefully considered staff scheduling decisions. © 2015 John Wiley & Sons Ltd.
Optimally setting up directed searches for continuous gravitational waves in Advanced LIGO O1 data
NASA Astrophysics Data System (ADS)
Ming, Jing; Papa, Maria Alessandra; Krishnan, Badri; Prix, Reinhard; Beer, Christian; Zhu, Sylvia J.; Eggenstein, Heinz-Bernd; Bock, Oliver; Machenschalk, Bernd
2018-02-01
In this paper we design a search for continuous gravitational waves from three supernova remnants: Vela Jr., Cassiopeia A (Cas A) and G347.3. These systems might harbor rapidly rotating neutron stars emitting quasiperiodic gravitational radiation detectable by the advanced LIGO detectors. Our search is designed to use the volunteer computing project Einstein@Home for a few months and assumes the sensitivity and duty cycles of the advanced LIGO detectors during their first science run. For all three supernova remnants, the sky positions of their central compact objects are well known but the frequency and spin-down rates of the neutron stars are unknown which makes the searches computationally limited. In a previous paper we have proposed a general framework for deciding on what target we should spend computational resources and in what proportion, what frequency and spin-down ranges we should search for every target, and with what search setup. Here we further expand this framework and apply it to design a search directed at detecting continuous gravitational wave signals from the most promising three supernova remnants identified as such in the previous work. Our optimization procedure yields broad frequency and spin-down searches for all three objects, at an unprecedented level of sensitivity: The smallest detectable gravitational wave strain h0 for Cas A is expected to be 2 times smaller than the most sensitive upper limits published to date, and our proposed search, which was set up and ran on the volunteer computing project Einstein@Home, covers a much larger frequency range.
Epidemiologic research using probabilistic outcome definitions.
Cai, Bing; Hennessy, Sean; Lo Re, Vincent; Small, Dylan S
2015-01-01
Epidemiologic studies using electronic healthcare data often define the presence or absence of binary clinical outcomes by using algorithms with imperfect specificity, sensitivity, and positive predictive value. This results in misclassification and bias in study results. We describe and evaluate a new method called probabilistic outcome definition (POD) that uses logistic regression to estimate the probability of a clinical outcome using multiple potential algorithms and then uses multiple imputation to make valid inferences about the risk ratio or other epidemiologic parameters of interest. We conducted a simulation to evaluate the performance of the POD method with two variables that can predict the true outcome and compared the POD method with the conventional method. The simulation results showed that when the true risk ratio is equal to 1.0 (null), the conventional method based on a binary outcome provides unbiased estimates. However, when the risk ratio is not equal to 1.0, the traditional method, either using one predictive variable or both predictive variables to define the outcome, is biased when the positive predictive value is <100%, and the bias is very severe when the sensitivity or positive predictive value is poor (less than 0.75 in our simulation). In contrast, the POD method provides unbiased estimates of the risk ratio both when this measure of effect is equal to 1.0 and not equal to 1.0. Even when the sensitivity and positive predictive value are low, the POD method continues to provide unbiased estimates of the risk ratio. The POD method provides an improved way to define outcomes in database research. This method has a major advantage over the conventional method in that it provided unbiased estimates of risk ratios and it is easy to use. Copyright © 2014 John Wiley & Sons, Ltd.
Ambiya, Vikas; Das, Taraprasad; Sharma, Savitri; Chhablani, Jay; Dave, Vivek; Jalali, Subhadra; Narayanan, Raja; Joseph, Joveeta
2016-12-01
The purpose of the study is to compare the clinico-microbiological profile and treatment outcome of in-house vs referred cases of post cataract surgery endophthalmitis in a tertiary eye care facility in South India. The clinical records of 50 culture-positive cases each of in-house (group A) and referred (group B) post cataract surgery endophthalmitis were analyzed. The management protocol was similar in both groups. The time to report to the institute was longer in group B (group B 13.63 [±11.67; 95% CI, 9.95-17.31] days; group A 6.83 [±7.61; 95% CI, 4.57-9.09] days; P = 0.002). The average inflammatory scores in presentation were comparable (group A 17.85 ± 5.83; group B 18.18 ± 7.35; P = 0.243). The final visual outcome was clinically superior in group A (≥20/200-group A 60.42% and group B 44%, P = 0.11; ≤20/400-group A 37.5% and group B 52%, P = 0.62), but statistically not significant. There were more gram-positive organisms in group A (62% vs 38%; P = 0.027) and more gram-negative organisms in group B (52% vs 24%; P = 0.007). Gram-positive bacteria were mostly sensitive to vancomycin (95.24% to 96.67%), but gram-negative bacteria were partly sensitive to ceftazidime (58.33% to 64%). One could suspect gram-negative infection more often in the referred cases of endophthalmitis. While vancomycin could continue to be the antibiotic of choice in gram-positive bacteria, specific antibiotic following due sensitivity for gram-negative bacteria should replace the empiric use of ceftazidime.
Periprosthetic infection: where do we stand with regard to Gram stain?
Ghanem, Elie; Ketonis, Constantinos; Restrepo, Camilo; Joshi, Ashish; Barrack, Robert
2009-01-01
Background and purpose One of the routinely used intraoperative tests for diagnosis of periprosthetic infection (PPI) is the Gram stain. It is not known if the result of this test can vary according to the type of joint affected or the number of specimen samples collected. We examined the role of this diagnostic test in a large cohort of patients from a single institution. Materials and methods A positive gram stain was defined as the visualization of bacterial cells or “many neutrophils” (> 5 per high-power field) in the smear. The sensitivity, specificity, and predictive values of each individual diagnostic arm of Gram stain were determined. Combinations were performed in series, which required both tests to be positive to confirm infection, and also in parallel, which necessitated both tests to be negative to rule out infection. Results The presence of organisms and “many” neutrophils on a Gram smear had high specificity (98–100%) and positive predictive value (89–100%) in both THA and TKA. The sensitivities (30–50%) and negative predictive values (70–79%) of the 2 tests were low for both joint types. When the 2 tests were combined in series, the specificity and positive predictive value were absolute (100%). The sensitivity and the negative predictive value improved for both THA and TKA (43–64% and 82%, respectively). Interpretation Although the 2 diagnostic arms of Gram staining can be combined to achieve improved negative predictive value (82%), Gram stain continues to have little value in ruling out PPI. With the advances in the field of molecular biology, novel diagnostic modalities need to be designed that can replace these traditional and poor tests. PMID:19297787
Multicentre study of fragrance allergy in Hungary. Immediate and late type reactions.
Temesvári, Erzsébet; Németh, Ilona; Baló-Banga, Mátyás J; Husz, Sándor; Kohánka, Valéria; Somos, Zsuzsa; Judák, Rita; Remenyik, E V A; Szegedi, Andrea; Nebenführer, László; Mészáros, Csilla; Horváth, Attila
2002-06-01
The authors followed the frequency of fragrance contact sensitization in Hungary in a multicentre study in the years 1998 and 1999. A total of 3,604 patients were tested with fragrance mix (FM), and positive reactions were observed in 294 (8.2%). In 160 FM hypersensitive patients, the study was continued with patch testing of the mix constituents (cinnamic alcohol, cinnamic aldehyde, eugenol, amyl cinnamic aldehyde, hydroxycitronellal, geraniol, isoeugenol, oak moss absolute). Of the patients tested, 70.6% produced positive reactions to the constituents. FM contact sensitization was mainly observed in female patients (74.4%). The incidence of contact urticaria in FM hypersensitive patients was 6.1%. Simultaneous patch test trials of other environmental contact allergens, in both early and late evaluations, mainly confirmed hypersensitivity reactions to balsams. Female dominance of hypersensitivity reactions observed during testing the individual components of the mix was striking (82.4%). In positive skin reactions, cinnamic alcohol, isoeugenol and oak moss provoked skin symptoms most frequently. We also tested the 104 patients who produced negative reactions to FM with the constituent individual allergens, with 11.9% positive incidence. The clinical symptoms of the patients were above all manifest in the form of contact eczema, located on the hands, face, eyelids and axillae. With this study, the authors, members of the Hungarian Contact Dermatitis Research Group, call attention to one of the most frequent allergens in the environment.
Lyral is an important sensitizer in patients sensitive to fragrances.
Frosch, P J; Johansen, J D; Menné, T; Rastogi, S C; Bruze, M; Andersen, K E; Lepoittevin, J P; Giménez Arnau, E; Pirker, C; Goossens, A; White, I R
1999-12-01
Contact allergy to fragrances is a common problem world-wide. The currently used fragrance mix (FM) for patch testing has only eight constituents and does not identify all fragrance-allergic patients. As perfumes may contain 100 or more substances, the search for markers for allergy continues. The synthetic fragrance 4-(4-hydroxy-4-methylpentyl)-3-cyclohexene carboxaldehyde (Lyral) was tested together with the FM and 11 other fragrance substances on consecutive patients in six European departments of dermatology. All patients were carefully questioned regarding a history of reactions to scented products in the past and were grouped into four categories: 'certain', 'probable', 'questionable' and 'none'. Lyral (5% in petrolatum) gave a positive reaction in 2.7% of 1855 patients (range 1.2-17%) and ranked next to 11.3% with FM allergy. Twenty-four patients reacted to both Lyral and FM, but 21 (1.1%) reacted positively only to Lyral. Of 124 patients with a 'certain' history, 53.2% reacted to the FM and a further 7.2% to Lyral only. If any kind of history of fragrance intolerance was given, 80% (40 of 50) of Lyral positive patients had a 'positive' history while only 58.6% (123 of 210) of FM positive patients had such a history; this difference was significant at P < 0.01. Lyral was identified by gas chromatography-mass spectrometry in some products which had caused an allergic contact dermatitis in four typical patients who showed a patch test positive to Lyral and negative or doubtful to FM. In conclusion, we recommend the testing of 5% Lyral (in petrolatum) in patients suspected of contact dermatitis.
SCALE Continuous-Energy Eigenvalue Sensitivity Coefficient Calculations
Perfetti, Christopher M.; Rearden, Bradley T.; Martin, William R.
2016-02-25
Sensitivity coefficients describe the fractional change in a system response that is induced by changes to system parameters and nuclear data. The Tools for Sensitivity and UNcertainty Analysis Methodology Implementation (TSUNAMI) code within the SCALE code system makes use of eigenvalue sensitivity coefficients for an extensive number of criticality safety applications, including quantifying the data-induced uncertainty in the eigenvalue of critical systems, assessing the neutronic similarity between different critical systems, and guiding nuclear data adjustment studies. The need to model geometrically complex systems with improved fidelity and the desire to extend TSUNAMI analysis to advanced applications has motivated the developmentmore » of a methodology for calculating sensitivity coefficients in continuous-energy (CE) Monte Carlo applications. The Contributon-Linked eigenvalue sensitivity/Uncertainty estimation via Tracklength importance CHaracterization (CLUTCH) and Iterated Fission Probability (IFP) eigenvalue sensitivity methods were recently implemented in the CE-KENO framework of the SCALE code system to enable TSUNAMI-3D to perform eigenvalue sensitivity calculations using continuous-energy Monte Carlo methods. This work provides a detailed description of the theory behind the CLUTCH method and describes in detail its implementation. This work explores the improvements in eigenvalue sensitivity coefficient accuracy that can be gained through the use of continuous-energy sensitivity methods and also compares several sensitivity methods in terms of computational efficiency and memory requirements.« less
An early warning system for high climate sensitivity? (Invited)
NASA Astrophysics Data System (ADS)
Pierrehumbert, R.
2010-12-01
The scientific case for the clear and present danger of global warming has been unassailable at least since the release of the Charney Report more than thirty years ago, if not longer. While prompt action to begin decarbonizing energy systems could still head off much of the potential warming, it is distinctly possible that emissions will continue unabated in the coming decades, leading to a doubling or more of pre-industrial carbon dioxide concentrations. At present, we are in the unenviable position of not even knowing how bad things will get if this scenario comes to pass, because of the uncertainty in climate sensitivity. If climate sensitivity is high, then the consequences will be dire, perhaps even catastrophic. As the world continues to warm in response to continued carbon dioxide emissions, will we at least be able to monitor the climate and provide an early warning that the planet is on a high-sensitivity track, if such turns out to be the case? At what point will we actually know the climate sensitivity? It has long been recognized that the prime contributor to uncertainty in climate sensitivity is uncertainty in cloud feedbacks. Study of paleoclimate and climate of the past century has not been able to resolve which models do cloud feedback most correctly, because of uncertainties in radiative forcing. In this talk, I will discuss monitoring requirements, and analysis techniques, that might have the potential to determine which climate models most faithfully represent climate feedbacks, and thus determine which models provide the best estimate of climate sensitivity. The endeavor is complicated by the distinction between transient climate response and equilibrium climate sensitivity. I will discuss the particular challenges posed by this issue, particularly in light of recent indications that the pattern of ocean heat storage may lead to different cloud feedbacks in the transient warming stage than apply once the system has reached equilibrium. Apart from this problem, the transient nature of climate response driven by increasing CO2 requires careful monitoring of ocean heat storage as well as top-of-atmosphere radiative budgets, if climate sensitivity is to be estimated. Water vapor feedback is not considered as uncertain as cloud feedback, but there is still a considerable potential for surprises. I will discuss microwave monitoring requirements for tracking water vapor feedback. At the other extreme, the longer term feedbacks that contribute to Earth System Sensitivity are even more uncertain than cloud feedbacks, particularly with regard to the terrestrial carbon cycle. Prospects for obtaining an early warning of a PETM-type organic carbon release seem bleak. Finally, I will discuss the particular challenge of obtaining an early warning of high climate sensitivity in the case that the climate system has a bifurcation.
An improvement of LLNA:DA to assess the skin sensitization potential of chemicals.
Zhang, Hongwei; Shi, Ying; Wang, Chao; Zhao, Kangfeng; Zhang, Shaoping; Wei, Lan; Dong, Li; Gu, Wen; Xu, Yongjun; Ruan, Hongjie; Zhi, Hong; Yang, Xiaoyan
2017-01-01
We developed a modified local lymph node assay based on ATP (LLNA:DA), termed the Two-Stage LLNA:DA, to further reduce the animal numbers in the identification of sensitizers. In the Two-Stage LLNA:DA procedure, 13 chemicals ranging from non-sensitizers to extreme sensitizers were selected. The first stage used reduced LLNA:DA (rLLNA:DA) to screen out sensitive chemicals. The second stage used LLNA:DA based on OECD 442 (A) to classify those potential sensitizers screened out in the first stage. In the first stage, the SIs of the methyl methacrylate, salicylic acid, methyl salicylate, ethyl salicylate, isopropanol and propanediol were below 1.8 and need not to be tested in the second step. Others continued to be tested by LLNA:DA. In the second stage, sodium lauryl sulphate and xylene were classified as weak sensitizers. a-hexyl cinnamic aldehyde and eugenol were moderate sensitizers. Benzalkonium chloride and glyoxal were strong sensitizers, and phthalic anhydride was an extreme sensitizer. The 9/9, 11/12, 10/11, and 8/13 (positive or negative only) categories of the Two-Stage LLNA:DA were consistent with those from the other methods (LLNA, LLNA:DA, GPMT/BT and HMT/HPTA), suggesting that Two-Stage LLNA:DA have a high coincidence rate with reported data. In conclusion, The Two-Stage LLNA:DA is in line with the "3R" rules, and can be a modification of LLNA:DA but needs more study.
Zhao, Xue Qiang; Bao, Xue Min; Wang, Chao; Xiao, Zuo Yi; Hu, Zhen Min; Zheng, Chun Li; Shen, Ren Fang
2017-10-01
Aluminum (Al) is ubiquitous and toxic to microbes. High Al 3+ concentration and low pH are two key factors responsible for Al toxicity, but our present results contradict this idea. Here, an Al-tolerant yeast strain Rhodotorula taiwanensis RS1 was incubated in glucose media containing Al with a continuous pH gradient from pH 3.1-4.2. The cells became more sensitive to Al and accumulated more Al when pH increased. Calculations using an electrostatic model Speciation Gouy Chapman Stern indicated that, the increased Al sensitivity of cells was associated with AlOH 2+ and Al(OH) 2 + rather than Al 3+ . The alcian blue (a positively charged dye) adsorption and zeta potential determination of cell surface indicated that, higher pH than 3.1 increased the negative charge and Al adsorption at the cell surface. Taken together, the enhanced sensitivity of R. taiwanensis RS1 to Al from pH 3.1-4.2 was associated with increased hydroxy-Al and cell-surface negativity.
Matthys, Walter; van Goozen, Stephanie H M; Snoek, Heddeke; van Engeland, Herman
2004-12-01
Response perseveration is the tendency to continue a response set for reward despite punishment. In the present study, response perseveration and sensitivity to reward and punishment were assessed in boys with oppositional defiant disorder (ODD). The study also examined the relation between punishment sensitivity and autonomic arousal. Nineteen ODD boys (mean age 9.8 years) and 20 normal control boys (NC) (mean age 9.7 years) were administered the door-opening task. In this task, the subject chooses either to open the next door or to stop playing; the opening of doors is initially rewarded and then increasingly punished. ODD boys opened more doors than NC boys. Following punishment, ODD boys took less time than NC boys before opening the next door, but did not differ from NC boys in time after reward. Mean skin conductance level was lower in ODD boys than in NC boys. The correlation coefficient between time after punishment and skin conductance level was moderately positive in the total sample. These results suggest that response perseveration in ODD boys is related to low punishment sensitivity and that skin conductance level is a marker of punishment sensitivity.
Charney, Noah D; Babst, Flurin; Poulter, Benjamin; Record, Sydne; Trouet, Valerie M; Frank, David; Enquist, Brian J; Evans, Margaret E K
2016-09-01
Predicting long-term trends in forest growth requires accurate characterisation of how the relationship between forest productivity and climatic stress varies across climatic regimes. Using a network of over two million tree-ring observations spanning North America and a space-for-time substitution methodology, we forecast climate impacts on future forest growth. We explored differing scenarios of increased water-use efficiency (WUE) due to CO2 -fertilisation, which we simulated as increased effective precipitation. In our forecasts: (1) climate change negatively impacted forest growth rates in the interior west and positively impacted forest growth along the western, southeastern and northeastern coasts; (2) shifting climate sensitivities offset positive effects of warming on high-latitude forests, leaving no evidence for continued 'boreal greening'; and (3) it took a 72% WUE enhancement to compensate for continentally averaged growth declines under RCP 8.5. Our results highlight the importance of locally adapted forest management strategies to handle regional differences in growth responses to climate change. © 2016 John Wiley & Sons Ltd/CNRS.
NASA Astrophysics Data System (ADS)
Popov, Denis E.; Tuchina, Elena S.; Chernova, Julia A.; Podshibyakin, Dmitry; Rudik, Dmitry V.; Samsonova, Maria; Gromov, Igor; Tuchin, Valery V.
2005-06-01
Gram-negative E. coli, gram-positive facultative anaerobe cocci Staphylococcus lugdensis, Micrococcus halobius, and Stomatococcus mucilaginosus as subjects of study were chosen. LEDs with spectrum maxima at 405 nm (without any exogenous sensitizer) and 660 nm (in conjunction with methylene blue) and power densities of 23 mW/cm2 and 5.7 mW/cm2 accordingly as continuous light sources were chosen. Photosensitized light's affect by methylene blue was studied on E. coli only. The original scheme of experiment set up was developed. It permits one to increase expositions quantity in each experiment for more certain trend's construction over dose curves and decrease parasite flora sowing. As a result of accomplished studies it was established that blue low-coherent light have unalike weak light's dose depending suppressing effect on cocci whereas red low-coherent light have a moderate dose-depended suppressing effect at low irradiation doses and a moderate dose-depended stimulating effect at high irradiation doses on sensitized by MeBlue E. coli. For all ofthis, but Staphylococcus morphology changes were observed.
Incidence of the WAIS-R Fuld profile in HIV-1 infection.
van Gorp, W G; Tulin, S J; Evans, G; Satz, P
1990-10-01
The incidence of a WAIS-R subtest "marker" sensitive to cholinergic dysfunction was assessed in a sample 116 homosexual males infected with HIV (Acquired Immunodeficiency Syndrome [AIDS] N = 40; AIDS Related Complex [ARC], N = 76). The incidence of positive profiles was low in the overall sample (11/116, 9%), and significantly lower than incidence rates reported for known cholinergic deficient groups (Alzheimer's disease; scopolamine). However, significantly more AIDS patients (8/40, 20%) than ARC patients (3/76, 4%) demonstrated positive profiles. These results suggest that, as a group, persons with ARC or AIDS do not show an increased incidence of the Fuld profile associated with cholinergic disruption, and offer continued support for diagnostic specificity of the Fuld formula for Alzheimer's disease.
Gerstl, Sibylle; Dunkley, Sophie; Mukhtar, Ahmed; De Smet, Martin; Baker, Samuel; Maikere, Jacob
2010-01-21
Most malaria rapid diagnostic tests (RDTs) use HRP2 detection, including Paracheck-Pf(R), but their utility is limited by persistent false positivity after treatment. PLDH-based tests become negative more quickly, but sensitivity has been reported below the recommended standard of 90%. A new pLDH test, CareStart three-line P.f/PAN-pLDH, claims better sensitivity with continued rapid conversion to negative. The study aims were to 1) compare sensitivity and specificity of CareStart to Paracheck-Pf(R) to diagnose falciparum malaria in children under five years of age, 2) assess how quickly false-positive CareStart tests become negative and 3) evaluate ease of use and inter-reader agreement of both tests. Participants were included if they were aged between two and 59 months, presenting to a Médecins Sans Frontières community health centre in eastern Sierra Leone with suspected malaria defined as fever (axillary temperature > 37.5 degrees C) and/or history of fever in the previous 72 hours and no signs of severe disease. The same capillary blood was used for the RDTs and the blood slide, the latter used as the gold standard reference. All positive participants were treated with supervised artesunate and amodiaquine treatment for three days. Participants with a persistent false-positive CareStart, but a negative blood slide on Day 2, were followed with repeated CareStart and blood slide tests every seven days until CareStart became negative or a maximum of 28 days. Sensitivity of CareStart was 99.4% (CI 96.8-100.0, 168/169) and of Paracheck-Pf(R), 98.8% (95% CI 95.8-99.8, 167/169). Specificity of CareStart was 96.0% (CI 91.9-98.4, 167/174) and of Paracheck-Pf(R), 74.7% (CI 67.6-81.0, 130/174) (p < 0.001). Neither test showed any change in sensitivity with decreasing parasitaemia. Of the 155 eligible follow-up CareStart participants, 63.9% (99/155) had a false-positive test on day 2, 21.3% (33/155) on day 7, 5.8% (9/155) on day 14, 1.9% (3/155) on day 21 and 0.6% (1/155) on day 28. The median time for test negativity was seven days. CareStart was as easy to use and interpret as Paracheck-Pf(R) with excellent inter-reader agreement. Both RDTs were highly sensitive, met WHO standards for the detection of falciparum malaria monoinfections where parasitaemia was >100 parasites/mul and were easy to use. CareStart persistent false positivity decreased quickly after successful anti-malarial treatment, making it a good choice for a RDT for a hyperendemic falciparum malaria area.
Kerhoulas, Lucy P; Kane, Jeffrey M
2012-01-01
Most dendrochronological studies focus on cores sampled from standard positions (main stem, breast height), yet vertical gradients in hydraulic constraints and priorities for carbon allocation may contribute to different growth sensitivities with position. Using cores taken from five positions (coarse roots, breast height, base of live crown, mid-crown branch and treetop), we investigated how radial growth sensitivity to climate over the period of 1895-2008 varies by position within 36 large ponderosa pines (Pinus ponderosa Dougl.) in northern Arizona. The climate parameters investigated were Palmer Drought Severity Index, water year and monsoon precipitation, maximum annual temperature, minimum annual temperature and average annual temperature. For each study tree, we generated Pearson correlation coefficients between ring width indices from each position and six climate parameters. We also investigated whether the number of missing rings differed among positions and bole heights. We found that tree density did not significantly influence climatic sensitivity to any of the climate parameters investigated at any of the sample positions. Results from three types of analyses suggest that climatic sensitivity of tree growth varied with position height: (i) correlations of radial growth and climate variables consistently increased with height; (ii) model strength based on Akaike's information criterion increased with height, where treetop growth consistently had the highest sensitivity and coarse roots the lowest sensitivity to each climatic parameter; and (iii) the correlation between bole ring width indices decreased with distance between positions. We speculate that increased sensitivity to climate at higher positions is related to hydraulic limitation because higher positions experience greater xylem tensions due to gravitational effects that render these positions more sensitive to climatic stresses. The low sensitivity of root growth to all climatic variables measured suggests that tree carbon allocation to coarse roots is independent of annual climate variability. The greater number of missing rings in branches highlights the fact that canopy development is a low priority for carbon allocation during poor growing conditions.
Nursing students' understanding of factors influencing ethical sensitivity: A qualitative study.
Borhani, Fariba; Abbaszadeh, Abbas; Mohsenpour, Mohaddeseh
2013-07-01
Ethical sensitivity is considered as a component of professional competency of nurses. Its effects on improvement of nurses' ethical performance and the therapeutic relationship between nurses and patients have been reported. However, very limited studies have evaluated ethical sensitivity. Since no previous Iranian research has been conducted in this regard, the present study aimed to review nursing students' understanding of effective factors on ethical sensitivity. This qualitative study was performed in Kerman, Iran, during 2009. It used semi-structured individual interviews with eight MSc nursing students to assess their viewpoints. It also included two focus groups. Purposive sampling was continued until data saturation. Data were analyzed using manifest content analysis. The students' understanding of factors influencing ethical sensitivity were summarized in five main themes including individual and spiritual characteristics, education, mutual understanding, internal and external controls, and experience of an immoral act. The findings of this study create a unique framework for sensitization of nurses in professional performance. The application of these factors in human resource management is reinforcement of positive aspects and decrease in negative aspects, in education can use for educational objectives setting, and in research can designing studies based on this framework and making related tools. It is noteworthy that presented classification was influenced by students themselves and mentioned to a kind of learning activity by them.
Millworkers' Asthma: Allergic Responses to the Grain Weevil (Sitophilus granarius)
Lunn, J. A.
1966-01-01
Two laboratory workers, who spent a considerable time each day handling grain infested by the grain weevil (Sitophilus granarius), developed allergic responses to this insect varying from rhinitis and pruritus to marked asthma. These findings suggested that weevil protein present in mill dust could result in sensitization in those exposed continuously. A pilot study was therefore undertaken on 75 volunteer millworkers to determine whether such sensitivity existed. A millworker was defined as anyone who worked in a flour mill or mill producing animal feed from mixed cereals, or who worked in grain-storing silos. Skin testing with weevil, mixed flour extracts, and a control was carried out on all 75 volunteers; 57% had a positive response to the weevil extract and 68% a positive response to the mixed flour extract. In a control group of 100 workers from two engineering firms matched for age and sex, 34% were positive to the weevil extract and 17% to mixed flour. From the initial 75 millworkers, 15 were selected for further study based on a positive skin response to the weevil and a history of a productive cough and chest tightness and wheezing when exposed to mill dust. The forced expiratory volume in one second (F.E.V.1·0) was measured after control inhalations and after weevil and mixed flour inhalations. Significant reductions of 20% and 15·4% were found in two subjects after inhalation of weevil extract. In one case wheezing and cough developed. The changes in F.E.V.1·0 were reversed after inhalation of a bronchodilator aerosol. Twenty-five of the control subjects with positive skin responses to the grain weevil were given similar provocation inhalations but none showed any significant change in F.E.V.1·0. This pilot study suggests that grain weevil sensitivity is an additional factor in millworkers' asthma. PMID:5929689
Performance of the dipstick screening test as a predictor of negative urine culture
Marques, Alexandre Gimenes; Doi, André Mario; Pasternak, Jacyr; Damascena, Márcio dos Santos; França, Carolina Nunes; Martino, Marinês Dalla Valle
2017-01-01
ABSTRACT Objective To investigate whether the urine dipstick screening test can be used to predict urine culture results. Methods A retrospective study conducted between January and December 2014 based on data from 8,587 patients with a medical order for urine dipstick test, urine sediment analysis and urine culture. Sensitivity, specificity, positive and negative predictive values were determined and ROC curve analysis was performed. Results The percentage of positive cultures was 17.5%. Nitrite had 28% sensitivity and 99% specificity, with positive and negative predictive values of 89% and 87%, respectively. Leukocyte esterase had 79% sensitivity and 84% specificity, with positive and negative predictive values of 51% and 95%, respectively. The combination of positive nitrite or positive leukocyte esterase tests had 85% sensitivity and 84% specificity, with positive and negative predictive values of 53% and 96%, respectively. Positive urinary sediment (more than ten leukocytes per microliter) had 92% sensitivity and 71% specificity, with positive and negative predictive values of 40% and 98%, respectively. The combination of nitrite positive test and positive urinary sediment had 82% sensitivity and 99% specificity, with positive and negative predictive values of 91% and 98%, respectively. The combination of nitrite or leukocyte esterase positive tests and positive urinary sediment had the highest sensitivity (94%) and specificity (84%), with positive and negative predictive values of 58% and 99%, respectively. Based on ROC curve analysis, the best indicator of positive urine culture was the combination of positives leukocyte esterase or nitrite tests and positive urinary sediment, followed by positives leukocyte and nitrite tests, positive urinary sediment alone, positive leukocyte esterase test alone, positive nitrite test alone and finally association of positives nitrite and urinary sediment (AUC: 0.845, 0.844, 0.817, 0.814, 0.635 and 0.626, respectively). Conclusion A negative urine culture can be predicted by negative dipstick test results. Therefore, this test may be a reliable predictor of negative urine culture. PMID:28444086
Song, Jie; Li, Mei; Zagaja, Gregory P; Taxy, Jerome B; Shalhav, Arieh L; Al-Ahmadie, Hikmat A
2010-11-01
To evaluate the accuracy of frozen section (FS) assessment of pelvic lymph nodes (PLNs) during radical prostatectomy (RP) in a large contemporary cohort; and to analyse the contribution of FS to surgical decision making in this setting. During a 4-year period at a single institution, RPs with PLN dissection (PLND) were reviewed. The number and size of the PLNs, and the size of metastases were measured. FS was performed on 349 bilateral PLNDs. Overall, 28 (8%) cases were positive for metastasis, 11 of which were detected by FS (39%). The 17 false negatives, all of which contained metastases smaller than 5 mm, were due to failure to identify and freeze the positive PLNs (11), failure to section at the level of the metastatic tumour (four), or interpretative error (two). The sensitivity was not affected by the number of sampled nodes. The size of metastasis was the determining factor for the accuracy of FS, with metastases of ≥ 5 mm having a sensitivity of 100%, and metastases of < 5 mm having a sensitivity of 10%. Among the 11 true positives, RP was aborted in eight cases and continued in three. During the same period, 261 PLNDs were performed without FS, and 18 (6.9%) had metastases. FS is highly accurate in detecting large, grossly evident metastases, but performs poorly on micrometastases. It is recommended that a two-step approach applied to routine FS starting with a careful gross examination followed by FS for only grossly suspicious PLNs. © 2010 THE AUTHORS. JOURNAL COMPILATION © 2010 BJU INTERNATIONAL.
NASA Technical Reports Server (NTRS)
Meyers, D. G.; Farmer, J. M.
1982-01-01
Gravity receptors of Dephnia magna were discovered on the basal segment of the swimming antennae and were shown to respond to upward water currents that pass the animal as it sinks between swimming strokes. Sensitivity of the gravity perceiving mechanism was tested by subjecting daphnids to a series of five decreasingly dense aqueous solutions (neutral density to water) in darkness (to avoid visual cues). Three-dimensional, video analysis of body position (pitch, yaw and roll) and swimming path (hop and sink, vertical and horizontal patterns) revealed a gradual threshold that occurred near a density difference between the animal and its environment of less than 0.25%. Because daphnids do not sink but continue to slide after stroking in the increased density solutions, gravity perception appears to occur during a vertical swing of the longitudinal body axis to the vertical plane, about their center of gravity, and, thereby, implies a multidirectional sensitivity for the antennal-socket setae.
NASA Astrophysics Data System (ADS)
Leaci, Paola; Astone, Pia; D'Antonio, Sabrina; Frasca, Sergio; Palomba, Cristiano; Piccinni, Ornella; Mastrogiovanni, Simone
2017-06-01
We describe a novel, very fast and robust, directed search incoherent method (which means that the phase information is lost) for periodic gravitational waves from neutron stars in binary systems. As a directed search, we assume the source sky position to be known with enough accuracy, but all other parameters (including orbital ones) are supposed to be unknown. We exploit the frequency modulation due to source orbital motion to unveil the signal signature by commencing from a collection of time and frequency peaks (the so-called "peakmap"). We validate our algorithm (pipeline), adding 131 artificial continuous-wave signals from pulsars in binary systems to simulated detector Gaussian noise, characterized by a power spectral density Sh=4 ×10-24 Hz-1 /2 in the frequency interval [70, 200] Hz, which is overall commensurate with the advanced detector design sensitivities. The pipeline detected 128 signals, and the weakest signal injected (added) and detected has a gravitational-wave strain amplitude of ˜10-24, assuming one month of gapless data collected by a single advanced detector. We also provide sensitivity estimations, which show that, for a single-detector data covering one month of observation time, depending on the source orbital Doppler modulation, we can detect signals with an amplitude of ˜7 ×10-25. By using three detectors, and one year of data, we would easily gain a factor 3 in sensitivity, translating into being able to detect weaker signals. We also discuss the parameter estimate proficiency of our method, as well as computational budget: sifting one month of single-detector data and 131 Hz-wide frequency range takes roughly 2.4 CPU hours. Hence, the current procedure can be readily applied in ally-sky schemes, sieving in parallel as many sky positions as permitted by the available computational power. Finally, we introduce (ongoing and future) approaches to attain sensitivity improvements and better accuracy on parameter estimates in view of the use on real advanced detector data.
Continuous positive airway pressure in severe obstructive sleep apnea reduces pain sensitivity.
Khalid, Imran; Roehrs, Timothy A; Hudgel, David W; Roth, Thomas
2011-12-01
To evaluate effects of CPAP on pain sensitivity in severe OSA patients. Within-subject treatment study. Hospital-based sleep disorders center. Twelve severe OSA patients (7 men, 5 women), 50.2 ± 12.5 years, with no pain. The morning after a diagnostic nocturnal polysomnogram (NPSG), patients underwent a training session of finger withdrawal latency (FWL) testing to a radiant heat stimulus, a validated human behavioral model of thermal nociception. Baseline FWL in seconds was obtained after the training session. CPAP pressure was titrated on a second night in the laboratory. Two nights after titration, patients returned to sleep in the laboratory on CPAP. FWL was tested in the morning after awakening, after 6-8 wks of CPAP use, and finally (within 6-8 weeks) after 2 nights of discontinuation of CPAP. Mean FWL in seconds (sec) was compared using MANOVAs with nights as the within subject variable. Apnea-hypopnea index (AHI) decreased from 50.9 ± 14.5 to 1.4 ± 1.0 with CPAP, and sleep continuity improved. In parallel, FWL increased significantly from a mean baseline of 9.8 ± 1.3 sec to 13.7 ± 5.1 sec (P = 0.01) and with continued CPAP use (5.1 ± 2.3 h nightly) for 6-8 weeks FWL remained elevated (21.1 ± 16.2 sec). After the 2-night CPAP discontinuation, apnea/hypopneas returned and sleep was fragmented (AHI = 32.6 ± 19.8). FWL decreased to 11.6 ± 5.9 sec relative to intermediate-term CPAP use (P = 0.03). CPAP treatment reduces pain sensitivity in OSA patients. Future studies will focus on patients with OSA and chronic pain and identify mediating mechanisms.
NASA Astrophysics Data System (ADS)
Dawson, Jeremy M.; Chen, Jingdong; Brown, Kolin S.; Famouri, Parviz F.; Hornak, Lawrence A.
2000-12-01
Implementation of closed-loop microelectromechanical system (MEMS) control enables mechanical microsystems to adapt to the demands of the environment that they are actuating, opening a broad range of new opportunities for future MEMS applications. Integrated optical microsystems have the potential to enable continuous in situ optical interrogation of MEMS microstructure position fully decoupled from the means of mechanical actuation that is necessary for realization of feedback control. We present the results of initial research evaluating through-wafer optical microprobes for surface micromachined MEMS integrated optical position monitoring. Results from the through-wafer free-space optical probe of a lateral comb resonator fabricated using the multiuser MEMS process service (MUMPS) indicate significant positional information content with an achievable return probe signal dynamic range of up to 80% arising from film transmission contrast. Static and dynamic deflection analysis and experimental results indicate a through-wafer probe positional signal sensitivity of 40 mV/micrometers for the present setup or 10% signal change per micrometer. A simulation of the application of nonlinear sliding control is presented illustrating position control of the lateral comb resonator structure given the availability of positional state information.
Phaeochromocytoma: diagnostic challenges for biochemical screening and diagnosis.
Barron, Jeffrey
2010-08-01
The aim of this article is to provide knowledge of the origin of catecholamines and metabolites so that there can be an informed approach to the methods for biochemical screening for a possible phaeochromocytoma; The article includes a review of catecholamine and metadrenaline metabolism, with methods used in biochemical screening. In the adrenal medulla and a phaeochromocytoma, catecholamines continuously leak from chromaffin granules into the cytoplasm and are converted to metadrenalines. For a phaeochromocytoma to become biochemically detectable, metnoradrenaline secretion needs to rise fourfold, whereas noradrenaline secretion needs to rise 15-fold. The prevalence of a sporadic phaeochromocytoma is low; therefore false-positive results exceed true-positive results. Assay sensitivity is high because it is important not to miss a possible phaeochromocytoma. The use of urine or plasma fractionated metadrenalines as the first-line test has been recommended due to improved sensitivity. A negative result excludes a phaeochromocytoma. Only after a sporadic phaeochromocytoma has been diagnosed biochemically is it cost effective to request imaging. Sensitivities and specificities of the assays differ according to pre-test probabilities of the presence of a phaeochromocytoma, with hereditary and incidentalomas having a higher pre-test probability than sporadic phaeochromocytoma. In conclusion, in screening for a possible phaeochromocytoma, biochemical investigations should be completed first to exclude or establish the diagnosis. The preferred biochemical screening test is fractionated metadrenalines, including methoxytyramine so as not to miss dopamine-secreting tumours.
Roubille, François; Fischer, Kady; Guensch, Dominik P; Tardif, Jean-Claude; Friedrich, Matthias G
2017-02-01
Oxygenation-sensitive cardiovascular magnetic resonance imaging (OS-CMR) is an emerging technique that can monitor changes in myocardial oxygenation in vivo. Obstructive sleep apnea syndrome (OSAS) is associated with endothelial and microcirculatory dysfunction and increased cardiovascular morbidity and mortality. Little is known about myocardial responses to apnea in patients with OSAS. We hypothesized that the coronary vascular response to hyperventilation and long breath-hold is diminished in patients with OSAS when compared to healthy volunteers. Twenty-nine OSAS patients and 36 healthy volunteers were prospectively enrolled. All CMR scans were performed on a clinical 3T system. Participants performed a breathing maneuver with 60s of hyperventilation followed by a maximal breath-hold. During the breath-hold, OS-CMR images were continuously acquired and signal intensity changes were measured by a blinded reader. Patients with OSAS were older than healthy volunteers (p<0.01) and presented more co-morbidities; 66% were currently treated with nocturnal positive airway pressure. Compared to healthy participants, the expected increase of myocardial oxygenation during the first 15s of the breath-hold was significantly lower in patients with OSAS (2.6±8.3% vs. 6.7±5.6%; p<0.05), and remained reduced at all time points during the breath-hold. Importantly this result was mainly driven by patients under continuous positive airway pressure (CPAP), suggesting that CPAP might have a greater impact on increase of myocardial oxygenation rather than OSAS itself. The myocardial vascular response to combined breathing maneuvers of hyperventilation followed by voluntary apnea is blunted in patients with obstructive sleep apnea. Clinical studies should now further define the clinical role of oxygenation-sensitive CMR in patients with respiratory disorders. Copyright © 2016 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
An Automatic Detection System of Lung Nodule Based on Multi-Group Patch-Based Deep Learning Network.
Jiang, Hongyang; Ma, He; Qian, Wei; Gao, Mengdi; Li, Yan
2017-07-14
High-efficiency lung nodule detection dramatically contributes to the risk assessment of lung cancer. It is a significant and challenging task to quickly locate the exact positions of lung nodules. Extensive work has been done by researchers around this domain for approximately two decades. However, previous computer aided detection (CADe) schemes are mostly intricate and time-consuming since they may require more image processing modules, such as the computed tomography (CT) image transformation, the lung nodule segmentation and the feature extraction, to construct a whole CADe system. It is difficult for those schemes to process and analyze enormous data when the medical images continue to increase. Besides, some state of the art deep learning schemes may be strict in the standard of database. This study proposes an effective lung nodule detection scheme based on multi-group patches cut out from the lung images, which are enhanced by the Frangi filter. Through combining two groups of images, a four-channel convolution neural networks (CNN) model is designed to learn the knowledge of radiologists for detecting nodules of four levels. This CADe scheme can acquire the sensitivity of 80.06% with 4.7 false positives per scan and the sensitivity of 94% with 15.1 false positives per scan. The results demonstrate that the multi-group patch-based learning system is efficient to improve the performance of lung nodule detection and greatly reduce the false positives under a huge amount of image data.
Mello, Juliana M R B; Bittelbrunn, Fernando P; Rockenbach, Marcio A B C; May, Guilherme G; Vedolin, Leonardo M; Kruger, Marilia S; Soldatelli, Matheus D; Zwetsch, Guilherme; de Miranda, Gabriel T F; Teixeira, Saone I P; Arruda, Bruna S
2017-12-01
To evaluate the quality assurance of mammography results at a reference institution for the diagnosis and treatment of breast cancer in southern Brazil, based on the BIRADS (Breast Imaging Reporting and Data System) 5th edition recommendations for auditing purposes. Retrospective cohort and cross-sectional study with 4502 patients (9668 mammographies)) who underwent at least one or both breast mammographies throughout 2013 at a regional public hospital, linked to a federal public university. The results were followed until 31 December 2014, including true positives (TPs), true negatives (TNs), false positives (FPs), false negatives (FNs), positive predictive values (PPVs), negative predictive value (NPV), sensitivity and specificity, with a confidence interval of 95%. The study showed high quality assurance, particularly regarding sensitivity (90.22%) and specificity (92.31%). The overall positive predictive value (PPV) was 65.35%, and the negative predictive value (NPV) was 98.32%. The abnormal interpretation rate (recall rate) was 12.26%. The results are appropriate when compared to the values proposed by the BIRADS 5th edition. Additionally, the study provided self-reflection considering our radiological practice, which is essential for improvements and collaboration regarding breast cancer detection. It may stimulate better radiological practice performance and continuing education, despite possible infrastructure and facility limitations. • Accurate quality performance rates are possible despite financial and governmental limitations. • Low-income institutions should develop standardised teamwork to improve radiological practice. • Regular mammography audits may help to increase the quality of public health systems.
Fate of redox-sensitive elements in two different East-African wetland systems
NASA Astrophysics Data System (ADS)
Glasner, Björn; Fiedler, Sabine
2017-04-01
We expect that an intensified cropping alters soil pH and Eh, and negatively affects the production potential of wetlands. Therefore, we investigated the redox-conditions in combination with the fate of different redox-sensitive elements in two prototypical wetland systems that show a high potential for food production in East-Africa. While the floodplains (observed near Ifakara, Kilombero District/Tanzania) serve as major crop producing areas in the region, the Inland Valleys (observed in Namulonge, Central District/Uganda) show a high potential for future production. Both systems have been divided into three positions; the fringe near to the slope, the center near to the river and the middle in between these two positions. In order to get a better understanding of the two systems we installed continuously measuring redox-electrodes in three different positions within both systems. Additionally, the fate of mineral elements was measured using ion-exchange resins with an installation period of 3-4 months. At the Tanzanian field sites the Eh-potential shows one major dry period with moderately reducing to well drained conditions in all sampling depths (10, 30, and 50 cm below ground) in all three positions during the measuring period from March 2015 to Dec 2016. Starting with the rains the Eh-potential drops from 700 mV (in 10 and 30 cm depth) to reducing conditions at all three sites - with intermediate brakes in the middle and fringe positions, showing that there has been no rain during these periods. At the Ugandan field sites the Eh-potential shows more fluctuations during the measuring period, especially in the center position in 2015 ( 750 to -200 mV in 30 and 50 cm depth). Having just the Eh-potential from the first 30 cm below ground it is not really possible to differentiate between dry- and rainy-seasons at the sites. The fate of redox-sensitive elements (Fe, Mn, and P) does not always correlate with the overall Eh-conditions (median) of the installation period. Short time events may play a crucial role in the fate of these elements.
Hengartner, M P; Heekeren, K; Dvorsky, D; Walitza, S; Rössler, W; Theodoridou, A
2017-09-01
The aim of this study was to critically examine the prognostic validity of various clinical high-risk (CHR) criteria alone and in combination with additional clinical characteristics. A total of 188 CHR positive persons from the region of Zurich, Switzerland (mean age 20.5 years; 60.2% male), meeting ultra high-risk (UHR) and/or basic symptoms (BS) criteria, were followed over three years. The test battery included the Structured Interview for Prodromal Syndromes (SIPS), verbal IQ and many other screening tools. Conversion to psychosis was defined according to ICD-10 criteria for schizophrenia (F20) or brief psychotic disorder (F23). Altogether n=24 persons developed manifest psychosis within three years and according to Kaplan-Meier survival analysis, the projected conversion rate was 17.5%. The predictive accuracy of UHR was statistically significant but poor (area under the curve [AUC]=0.65, P<.05), whereas BS did not predict psychosis beyond mere chance (AUC=0.52, P=.730). Sensitivity and specificity were 0.83 and 0.47 for UHR, and 0.96 and 0.09 for BS. UHR plus BS achieved an AUC=0.66, with sensitivity and specificity of 0.75 and 0.56. In comparison, baseline antipsychotic medication yielded a predictive accuracy of AUC=0.62 (sensitivity=0.42; specificity=0.82). A multivariable prediction model comprising continuous measures of positive symptoms and verbal IQ achieved a substantially improved prognostic accuracy (AUC=0.85; sensitivity=0.86; specificity=0.85; positive predictive value=0.54; negative predictive value=0.97). We showed that BS have no predictive accuracy beyond chance, while UHR criteria poorly predict conversion to psychosis. Combining BS with UHR criteria did not improve the predictive accuracy of UHR alone. In contrast, dimensional measures of both positive symptoms and verbal IQ showed excellent prognostic validity. A critical re-thinking of binary at-risk criteria is necessary in order to improve the prognosis of psychotic disorders. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Microbial ecology measurement system
NASA Technical Reports Server (NTRS)
1972-01-01
The sensitivity and potential rapidity of the PIA test that was demonstrated during the feasibility study warranted continuing the effort to examine the possibility of adapting this test to an automated procedure that could be used during manned missions. The effort during this program has optimized the test conditions for two important respiratory pathogens, influenza virus and Mycoplasma pneumoniae, developed a laboratory model automated detection system, and investigated a group antigen concept for virus detection. Preliminary tests on the handling of oropharygeal clinical samples for PIA testing were performed using the adenovirus system. The results obtained indicated that the PIA signal is reduced in positive samples and is increased in negative samples. Treatment with cysteine appeared to reduce nonspecific agglutination in negative samples but did not maintain the signal in positive samples.
New Optimizations of Microcalorimeter Arrays for High-Resolution Imaging X-ray Spectroscopy
NASA Astrophysics Data System (ADS)
Kilbourne, Caroline
We propose to continue our successful research program in developing arrays of superconducting transition-edge sensors (TES) for x-ray astrophysics. Our standard 0.3 mm TES pixel achieves better than 2.5-eV resolution, and we now make 32x32 arrays of such pixels. We have also achieved better than 1-eV resolution in smaller pixels, and promising performance in a range of position-sensitive designs. We propose to continue to advance the designs of both the single-pixel and position-sensitive microcalorimeters so that we can produce arrays suitable for several x-ray spectroscopy observatories presently in formulation. We will also investigate various array and pixel optimizations such as would be needed for large arrays for surveys, large- pixel arrays for diffuse soft x-ray measurements, or sub-arrays of fast pixels optimized for neutron-star burst spectroscopy. In addition, we will develop fabrication processes for integrating sub-arrays with very different pixel designs into a monolithic focal-plane array to simplify the design of the focal-plane assembly and make feasible new detector configurations such as the one currently baselined for AXSIO. Through a series of measurements on test devices, we have improved our understanding of the weak-link physics governing the observed resistive transitions in TES detectors. We propose to build on that work and ultimately use the results to improve the immunity of the detector to environmental magnetic fields, as well as its fundamental performance, in each of the targeted optimizations we are developing.
Xu, Xiaodong; Zhou, Xiaolin
2016-02-01
This study investigated how topic shift and topic continuation influence pronoun interpretation in Chinese. ERPs recorded on pronouns in topic structure showed stronger and earlier late positive responses (P600) for the topic-shift than for the topic-continuation conditions. However, in nontopic structure where the subject (denoting only subjecthood), rather than the topic (denoting both topichood and subjecthood), acted as the antecedent of the pronoun, almost indistinguishable P600 responses were obtained on the pronoun regardless of whether it was referring to the subject (i.e., subject continuation) or the object (i.e., subject shift). Moreover, stronger and earlier P600 responses were elicited by pronouns in the topic-shift than in the subject-shift conditions, although there was no difference between the topic-continuation and the subject-continuation conditions. These findings suggest that topic shift results in greater difficulty in the resolution stage of referential processing, although the bonding process is not sensitive to the manipulation of topic status, and that topic has a privileged cognitive status relative to other nontopic entities (e.g., subject) in real-time language processing. © 2015 Society for Psychophysiological Research.
Use of SCALE Continuous-Energy Monte Carlo Tools for Eigenvalue Sensitivity Coefficient Calculations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perfetti, Christopher M; Rearden, Bradley T
2013-01-01
The TSUNAMI code within the SCALE code system makes use of eigenvalue sensitivity coefficients for an extensive number of criticality safety applications, such as quantifying the data-induced uncertainty in the eigenvalue of critical systems, assessing the neutronic similarity between different critical systems, and guiding nuclear data adjustment studies. The need to model geometrically complex systems with improved fidelity and the desire to extend TSUNAMI analysis to advanced applications has motivated the development of a methodology for calculating sensitivity coefficients in continuous-energy (CE) Monte Carlo applications. The CLUTCH and Iterated Fission Probability (IFP) eigenvalue sensitivity methods were recently implemented in themore » CE KENO framework to generate the capability for TSUNAMI-3D to perform eigenvalue sensitivity calculations in continuous-energy applications. This work explores the improvements in accuracy that can be gained in eigenvalue and eigenvalue sensitivity calculations through the use of the SCALE CE KENO and CE TSUNAMI continuous-energy Monte Carlo tools as compared to multigroup tools. The CE KENO and CE TSUNAMI tools were used to analyze two difficult models of critical benchmarks, and produced eigenvalue and eigenvalue sensitivity coefficient results that showed a marked improvement in accuracy. The CLUTCH sensitivity method in particular excelled in terms of efficiency and computational memory requirements.« less
Diether, S; Schaeffel, F
1999-07-01
Experiments in animal models have shown that the retinal analyzes the image to identify the position of the plane of focus and fine-tunes the growth of the underlying sclera. It is fundamental to the understanding of the development of refractive errors to know which image features are processed. Since the position of the image plane fluctuates continuously with accommodative status and viewing distance, a meaningful control of refractive development can only occur by an averaging procedure with a long time constant. As a candidate for a retinal signal for enhanced eye growth and myopia we propose the level of contrast adaptation which varies with the average amount of defocus. Using a behavioural paradigm, we have found in chickens (1) that contrast adaptation (CA, here referred to as an increase in contrast sensitivity) occurs at low spatial frequencies (0.2 cyc/deg) already after 1.5 h of wearing frosted goggles which cause deprivation myopia, (2) that CA also occurs with negative lenses (-7.4D) and positive lenses (+6.9D) after 1.5 h, at least if accommodation is paralyzed and, (3) that CA occurs at a retinal level or has, at least, a retinal component. Furthermore, we have studied the effects of atropine and reserpine, which both suppress myopia development, on CA. Quisqualate, which causes retinal degeneration but leaves emmetropization functional, was also tested. We found that both atropine and reserpine increase contrast sensitivity to a level where no further CA could be induced by frosted goggles. Quisqualate increased only the variability of refractive development and of contrast sensitivity. Taken together, CA occurring during extended periods of defocus is a possible candidate for a retinal error signal for myopia development. However, the situation is complicated by the fact that there must be a second image processing mode generating a powerful inhibitory growth signal if the image is in front of the retina, even with poor images (Diether, S., & Schaeffel, F. (1999).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perfetti, Christopher M; Rearden, Bradley T
2014-01-01
This work introduces a new approach for calculating sensitivity coefficients for generalized neutronic responses to nuclear data uncertainties using continuous-energy Monte Carlo methods. The approach presented in this paper, known as the GEAR-MC method, allows for the calculation of generalized sensitivity coefficients for multiple responses in a single Monte Carlo calculation with no nuclear data perturbations or knowledge of nuclear covariance data. The theory behind the GEAR-MC method is presented here, and proof of principle is demonstrated by using the GEAR-MC method to calculate sensitivity coefficients for responses in several 3D, continuous-energy Monte Carlo applications.
Nyqvist, K H; Anderson, G C; Bergman, N; Cattaneo, A; Charpak, N; Davanzo, R; Ewald, U; Ibe, O; Ludington-Hoe, S; Mendoza, S; Pallás-Allonso, C; Ruiz Peláez, J G; Sizun, J; Widström, A-M
2010-06-01
The hallmark of Kangaroo Mother Care (KMC) is the kangaroo position: the infant is cared for skin-to-skin vertically between the mother's breasts and below her clothes, 24 h/day, with father/substitute(s) participating as KMC providers. Intermittent KMC (for short periods once or a few times per day, for a variable number of days) is commonly employed in high-tech neonatal intensive care units. These two modalities should be regarded as a progressive adaptation of the mother-infant dyad, ideally towards continuous KMC, starting gradually and progressively with intermittent KMC. The other components in KMC are exclusive breastfeeding (ideally) and early discharge in kangaroo position with strict follow-up. Current evidence allows the following general statements about KMC in affluent and low-income settings: KMC enhances bonding and attachment; reduces maternal postpartum depression symptoms; enhances infant physiologic stability and reduces pain, increases parental sensitivity to infant cues; contributes to the establishment and longer duration of breastfeeding and has positive effects on infant development and infant/parent interaction. Therefore, intrapartum and postnatal care in all types of settings should adhere to a paradigm of nonseparation of infants and their mothers/families. Preterm/low-birth-weight infants should be regarded as extero-gestational foetuses needing skin-to-skin contact to promote maturation. Kangaroo Mother Care should begin as soon as possible after birth, be applied as continuous skin-to-skin contact to the extent that this is possible and appropriate and continue for as long as appropriate.
Sattler, Tatjana; Wodak, Eveline; Revilla-Fernández, Sandra; Schmoll, Friedrich
2014-12-18
In recent years, several new ELISAs for the detection of antibodies against the porcine reproductive and respiratory disease virus (PRRSV) in pig serum have been developed. To interpret the results, specificity and sensitivity data as well as agreement to a reference ELISA must be available. In this study, three commercial ELISAs (INgezim PRRS 2.0 - ELISA II, Priocheck® PRRSV Ab porcine - ELISA III and CIVTEST suis PRRS E/S PLUS - ELISA IV, detecting PRRSV type 1 antibodies) were compared to a standard ELISA (IDEXX PRRS X3 Ab Test - ELISA I). The serum of three pigs vaccinated with an attenuated PRRSV live vaccine (genotype 2) was tested prior to and several times after the vaccination. Furthermore, serum samples of 245 pigs of PRRSV positive herds, 309 pigs of monitored PRRSV negative herds, 256 fatteners of assumed PRRSV negative herds with unknown herd history and 92 wild boars were tested with all four ELISAs. ELISAs II and III were able to detect seroconversion of vaccinated pigs with a similar reliability. According to kappa coefficient, the results showed an almost perfect agreement between ELISA I as reference and ELISA II and III (kappa > 0.8), and substantial agreement between ELISA I and ELISA IV (kappa = 0.71). Sensitivity of ELISA II, III and IV was 96.0%, 100% and 91.5%, respectively. The specificity of the ELISAs determined in samples of monitored PRRSV negative herds was 99.0%, 95.1% and 96.4%, respectively. In assumed negative farms that were not continually monitored, more positive samples were found with ELISA II to IV. The reference ELISA I had a specificity of 100% in this study. All tested ELISAs were able to detect a PRRSV positive herd. The specificity and sensitivity of the tested commercial ELISAs, however, differed. ELISA II had the highest specificity and ELISA III had the highest sensitivity in comparison to the reference ELISA. ELISA IV had a lower sensitivity and specificity than the other ELISAs.
NASA Astrophysics Data System (ADS)
Kumar, Mukesh; Ojha, A.; Garg, A. D.; Puntambekar, T. A.; Senecha, V. K.
2017-02-01
According to the quasi electrostatic model of linear response capacitive beam position monitor (BPM), the position sensitivity of the device depends only on the aperture of the device and it is independent of processing frequency and load impedance. In practice, however, due to the inter-electrode capacitive coupling (cross talk), the actual position sensitivity of the device decreases with increasing frequency and load impedance. We have taken into account the inter-electrode capacitance to derive and propose a new analytical expression for the position sensitivity as a function of frequency and load impedance. The sensitivity of a linear response shoe-box type BPM has been obtained through simulation using CST Studio Suite to verify and confirm the validity of the new analytical equation. Good agreement between the simulation results and the new analytical expression suggest that this method can be exploited for proper designing of BPM.
Detection and quantification of intraperitoneal fluid using electrical impedance tomography.
Sadleir, R J; Fox, R A
2001-04-01
A prototype electrical impedance tomography system was evaluated prior to its use for the detection of intraperitoneal bleeding, with the assistance of patients undergoing continuous ambulatory peritoneal dialysis (CAPD). The system was sensitive enough to detect small amounts of dialysis fluid appearing in subtractive images over short time periods. Uniform sensitivity to blood appearing anywhere within the abdominal cavity was produced using a post-reconstructive filter that corrected for changes in apparent resistivity of anomalies with their radial position. The image parameter used as an indication of fluid quantity, the resistivity index, varied approximately linearly with the quantity of fluid added. A test of the system's response to the introduction of conductive fluid out of the electrode plane (when a blood-equivalent fluid was added to the stomach) found that the sensitivity of the system was about half that observed in the electrode plane. Breathing artifacts were found to upset quantitative monitoring of intraperitoneal bleeding, but only on time scales short compared with the fluid administration rate. Longer term breathing changes, such as those due to variations in the functional residual capacity of the lungs, should ultimately limit the sensitivity over long time periods.
High sensitivity waveguide micro-displacement sensor based on intermodal interference
NASA Astrophysics Data System (ADS)
Ji, Lanting; He, Guobing; Gao, Yang; Xu, Yan; Liang, Honglei; Sun, Xiaoqiang; Wang, Xibin; Yi, Yunji; Chen, Changming; Wang, Fei; Zhang, Daming
2017-11-01
An optical waveguide displacement sensor according to core-cladding modes interference is theoretically proposed and experimentally demonstrated. Ultraviolet sensitive SU-8 polymer on silica is used as the guiding layer. It is covered by a 12 nm thick planar gold grating. The air gap sensing head which consists of the waveguide end and the single-mode fiber facet can realize the displacement detection by monitoring the wavelength dip shifting in transmission spectra. Cladding modes propagating in the exposed SU-8 can be effectively excited by the end-fire coupling because of the mode field mismatch between the SU-8 waveguide and lead-in fiber. A sinusoidal pattern transmission spectrum in C-band with the depth of over 14 dB can be observed due to the interference between the core and cladding modes. Peaks in the transmission spectrum vary continuously with the position offset of input fiber facet from the center of waveguide end. Both the sensitivity and the stability of sensing are enhanced by the introduction of nanometric gold gratings. The fabricated displacement sensor exhibits a high sensitivity of 2.3 nm μm-1, promising potentials for micromechanical processing and integrated optics application.
Yokota, K; Yamaguchi, K; Takeshita, T; Morimoto, K
1998-06-01
A definitive role for allergen-specific IgG4 as either an anaphylactic or a blocking antibody, or both, remains controversial. A population of 148 workers from two condenser plants (A and B) using epoxy resin with methyltetrahydrophthalic anhydride (MTHPA) was studied to evaluate the significance of MTHPA-specific IgG4 antibody. The workers were evaluated through questionnaire and serological investigations. Ninety-seven (66%) of the currently exposed workers had positive MTHPA-specific IgE. IgE-sensitized workers in each plant had significantly more eye and nose complaints than unsensitized workers (P < 0.03). As the result of multiple logistic analysis, specific IgE antibodies was the most important predictor of work-related symptoms and its effect was greater than that of specific IgG4 (odds ratio 16.7 and 3.68, respectively). These indicate an IgE-mediated mechanism in most cases of work-related symptoms associated with MTHPA exposure. However, it cannot be denied that specific IgG4 is an anaphylactic antibody. Furthermore, IgE-sensitized workers in these plants displayed work-related symptoms despite the presence of specific IgG4. The frequency of positive specific IgG4 in continuously exposed workers was significantly (P < 0.02) higher in plant A than in plant B, reflecting the difference of the MTHPA levels between the two plants. In plant A, the frequency of positive specific IgG4 was significantly (P < 0.002) higher in continuously exposed workers than in intermittently exposed workers. Multiple regression analysis also confirmed that plant and exposure style contributed significantly (P < 0.01) to the determination of specific IgG4 levels. These results suggest that work-related eye and nasal symptoms are likely to be IgE-mediated, and that specific IgG4 may reflect the intensity of MTHPA exposure and may not act as a blocking antibody.
Interaction of root gravitropism and phototropism in Arabidopsis wild-type and starchless mutants.
Vitha, S; Zhao, L; Sack, F D
2000-02-01
Root gravitropism in wild-type Arabidopsis and in two starchless mutants, pgm1-1 and adg1-1, was evaluated as a function of light position to determine the relative strengths of negative phototropism and of gravitropism and how much phototropism affects gravitropic measurements. Gravitropism was stronger than phototropism in some but not all light positions in wild-type roots grown for an extended period, indicating that the relationship between the two tropisms is more complex than previously reported. Root phototropism significantly influenced the time course of gravitropic curvature and the two measures of sensitivity. Light from above during horizontal exposure overestimated all three parameters for all three genotypes except the wild-type perception time. At the irradiance used (80 micromol m(-2) s(-1)), the shortest periods of illumination found to exaggerate gravitropism were 45 min of continuous illumination and 2-min doses of intermittent illumination. By growing roots in circumlateral light or by gravistimulating in the dark, corrected values were obtained for each gravitropic parameter. Roots of both starchless mutants were determined to be about three times less sensitive than prior estimates. This study demonstrates the importance of accounting for phototropism in the design of root gravitropism experiments in Arabidopsis.
Environmental considerations for 3D seismic in Louisianna wetlands
DOE Office of Scientific and Technical Information (OSTI.GOV)
Browning, G.; Dillane, T.; Baaren, P. van
1996-11-01
Louisiana swamps have been host to seismic crews for many years. Results from recent 3D surveys indicate that well planned and executed seismic operations have a minimal and short term impact in these environmentally sensitive wetlands. Pre-planning identifies challenges that require use of improved technology and work procedures. These include multi-channel radio telemetry recording systems, ramming of dynamite and hydrophones as opposed to drilling, DGPS positioning and coordinated use of Airboats, buggies and helicopters. In addition to minimal environmental impact, increased data quality, reduced cost and shorter project duration have been achieved as a result of these efforts. Unlike 2Dmore » surveys, where profile positioning is flexible, 3D surveys involve high density coverage over many square miles operated by numerous personnel. Survey design includes minimizing repeated traffic and crossing points. Survey operations require environmental participation and commitment from every person involved in the project. This includes a thorough orientation and training program with strong emphasis on environmental sensitivity and awareness. Close co-ordination between regulatory agencies, clients and the contractor is a key factor in all aspects of the survey planning and operation. Benefits from these efforts are significant, measurable and continue to improve.« less
Interaction of root gravitropism and phototropism in Arabidopsis wild-type and starchless mutants
NASA Technical Reports Server (NTRS)
Vitha, S.; Zhao, L.; Sack, F. D.
2000-01-01
Root gravitropism in wild-type Arabidopsis and in two starchless mutants, pgm1-1 and adg1-1, was evaluated as a function of light position to determine the relative strengths of negative phototropism and of gravitropism and how much phototropism affects gravitropic measurements. Gravitropism was stronger than phototropism in some but not all light positions in wild-type roots grown for an extended period, indicating that the relationship between the two tropisms is more complex than previously reported. Root phototropism significantly influenced the time course of gravitropic curvature and the two measures of sensitivity. Light from above during horizontal exposure overestimated all three parameters for all three genotypes except the wild-type perception time. At the irradiance used (80 micromol m(-2) s(-1)), the shortest periods of illumination found to exaggerate gravitropism were 45 min of continuous illumination and 2-min doses of intermittent illumination. By growing roots in circumlateral light or by gravistimulating in the dark, corrected values were obtained for each gravitropic parameter. Roots of both starchless mutants were determined to be about three times less sensitive than prior estimates. This study demonstrates the importance of accounting for phototropism in the design of root gravitropism experiments in Arabidopsis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nadhira, Vebi, E-mail: vebi@tf.itb.ac.id; Kurniadi, Deddy, E-mail: vebi@tf.itb.ac.id; Juliastuti, E., E-mail: vebi@tf.itb.ac.id
The importance of monitoring the quality of vegetables and fruits is prosperity by giving a competitive advantage for producer and providing a more healthy food for consumer. Diffuse Optical Tomography (DOT) is offering the possibility to detect the internal defects of the agricultural produce quality. Fluorescence diffuse optical tomography (FDOT) is the development of DOT, offering the possibilities to improve spatial resolution and to contrast image. The purpose of this research is to compare FDOT and DOT in forward analysis with continuous wave approach. The scattering and absorbing parameters of potatoes are used to represent the real condition. The objectmore » was illuminated by the NIR source from some positions on the boundary of object. A set of NIR detector are placed on the peripheral position of the object to measure the intensity of propagated or emitted light. In the simulation, we varied a condition of object then we analyzed the sensitivity of forward problem. The result of this study shows that FDOT has a better sensitivity than DOT and a better potential to monitor internal defects of agricultural produce because of the contrast value between optical and fluorescence properties of agricultural produce normal tissue and defects.« less
Khan, S; Harish, B N; Menezes, G A; Acharya, N S; Parija, S C
2012-11-01
Typhoid fever caused by Salmonella Typhi continues to be a major health problem in spite of the use of antibiotics and the development of newer antibacterial drugs. Inability to make an early laboratory diagnosis and resort to empirical therapy, often lead to increased morbidity and mortality in cases of typhoid fever. This study was aimed to optimize a nested PCR for early diagnosis of typhoid fever and using it as a diagnostic tool in culture negative cases of suspected typhoid fever. Eighty patients with clinical diagnosis of typhoid fever and 40 controls were included in the study. The blood samples collected were subjected to culture, Widal and nested PCR targeting the flagellin gene of S. Typhi. The sensitivity of PCR on blood was found to be 100 per cent whereas the specificity was 76.9 per cent. The positive predictive value (PPV) of PCR was calculated to be 76.9 per cent with an accuracy of 86 per cent. None of the 40 control samples gave a positive PCR. Due to its high sensitivity and specificity nested PCR can be used as a useful tool to diagnose clinically suspected, culture negative cases of typhoid fever.
Neurons as sensors: individual and cascaded chemical sensing.
Prasad, Shalini; Zhang, Xuan; Yang, Mo; Ozkan, Cengiz S; Ozkan, Mihrimah
2004-07-15
A single neuron sensor has been developed based on the interaction of gradient electric fields and the cell membrane. Single neurons are rapidly positioned over individual microelectrodes using positive dielectrophoretic traps. This enables the continuous extracellular electrophysiological measurements from individual neurons. The sensor developed using this technique provides the first experimental method for determining single cell sensitivity; the speed of response and the associated physiological changes to a broad spectrum of chemical agents. Binding of specific chemical agents to a specific combination of receptors induces changes to the extracellular membrane potential of a single neuron, which can be translated into unique "signature patterns" (SP), which function as identification tags. Signature patterns are derived using Fast Fourier Transformation (FFT) analysis and Wavelet Transformation (WT) analysis of the modified extracellular action potential. The validity and the sensitivity of the system are demonstrated for a variety of chemical agents ranging from behavior altering chemicals (ethanol), environmentally hazardous agents (hydrogen peroxide, EDTA) to physiologically harmful agents (pyrethroids) at pico- and femto-molar concentrations. The ability of a single neuron to selectively identify specific chemical agents when injected in a serial manner is demonstrated in "cascaded sensing".
Reward/punishment sensitivities among internet addicts: Implications for their addictive behaviors.
Dong, Guangheng; Hu, Yanbo; Lin, Xiao
2013-10-01
Internet addiction disorder (IAD) has raised widespread public health concerns. In this study, we used a gambling task to simulate extreme win/lose situations to find the reward/punishment sensitivities after continuous wins and losses. FMRI data were collected from 16 IAD subjects (21.4±3.1years) and 15 healthy controls (HC, 22.1±3.6years). Group comparisons showed higher superior frontal gyrus activations after continuous wins for IAD subjects than for HC. The brain activities in IAD subjects were not disturbed by their losses. In addition, IAD participants showed decreased posterior cingulate activation compared to HC after continuous losses. These results indicated that IAD participants showed preference to win while neglecting their losses. Therefore they engaged less executive endeavor to control their frustration after continuous losses. Taken together, we concluded that IAD subjects showed enhanced sensitivity to win and decreased sensitivity to lose. This can help us understand why IAD subjects continue playing online even after noticing the severe negative consequences of their behaviors. © 2013.
Rufai, Syed Beenish; Singh, Amit; Singh, Jitendra; Kumar, Parveen; Sankar, Manimuthu Mani; Singh, Sarman
2017-08-01
Tuberculous meningitis (TBM) is the most severe form of extra-pulmonary tuberculosis (TB) due to association of diseases with high rates of mortality and morbidity. Diagnosis continues to be a clinical challenge as microbiological confirmation is rare and time consuming resulting in delayed treatment. Xpert MTB/RIF assay is a rapid and simple test, which has been endorsed by World Health Organization as an initial diagnostic test for the diagnosis of TBM. However, evidence still lacks for its performance on cerebrospinal fluid (CSF) for the diagnosis of TBM especially from India. A total of 267 CSF samples from patients with high clinico-radiological suspicion of TBM were included in this study. Ziehl-Neelsen (ZN) staining, BACTEC Mycobacterial Growth Indicator Tube (MGIT-960) culture system, and Xpert MTB/RIF assay (using cartridge version G4) were tested on all samples. Of total 267 samples, all were negative for smear AFB and 52 (19.5%) were culture positive by MGIT-960 culture system. However, out of 52 (19.5%) cultures detected positive by MGIT-960, 5 (9.6%) were detected as resistant to rifampicin. Xpert MTB/RIF assay was positive in 38 (14.2%) samples and negative in 223 (83.5%) samples. Cartridge error was detected in 6 (2.2%) samples, which could not be repeated due to insufficient sample volume. The sensitivity and specificity of Xpert MTB/RIF assay in comparison to MGIT-960 was 55.1% (95%, CI: 40.2-69.3) and 94.8% (95%, CI: 90.9-97.4) respectively. Overall, Xpert MTB/RIF assay detected 38 (14.2%) as positive for MTB of which 4 (10.5%), 31 (81.6%) and 3 (7.9%) were found to be rifampicin resistant, sensitive and indeterminate respectively. Xpert MTB/RIF assay showed lower sensitivity as compared to MGIT 960 culture for the diagnosis of TBM from CSF samples. Copyright © 2017 The British Infection Association. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mihailescu, Lucian
This disclosure provides systems, methods, and apparatus related to ion beam therapy. In one aspect, a system includes a position sensitive detector and a collimator. The position sensitive detector configured to detect gamma rays generated by an ion beam interacting with a target. The collimator is positioned between the target and the position sensitive detector. The collimator includes a plurality of knife-edge slits, with a first knife-edge slit intersecting with a second knife-edge slit.
A Framework of Complex Adaptive Systems: Parents As Partners in the Neonatal Intensive Care Unit.
DʼAgata, Amy L; McGrath, Jacqueline M
2016-01-01
Advances in neonatal care are allowing for increased infant survival; however, neurodevelopmental complications continue. Using a complex adaptive system framework, a broad analysis of the network of agents most influential to vulnerable infants in the neonatal intensive care unit (NICU) is presented: parent, nurse, and organization. By exploring these interconnected relationships and the emergent behaviors, a model of care that increases parental caregiving in the NICU is proposed. Supportive parent caregiving early in an infant's NICU stay has the potential for more sensitive caregiving and enhanced opportunities for attachment, perhaps positively impacting neurodevelopment.
The Role of Allergen Exposure and Avoidance in Asthma
Baxi, Sachin N.; Phipatanakul, Wanda
2010-01-01
Allergy testing and avoidance of allergens plays an important role in asthma control. Increased allergen exposure, in genetically susceptible individuals, can lead to allergic sensitization. Continued allergen exposure can increase the risk of asthma and other allergic diseases. In a patient with persistent asthma, identification of indoor and outdoor allergens and subsequent avoidance can improve symptoms. Often times, a patient will have multiple allergies and the avoidance plan should target all positive allergens. Several studies have shown that successful allergen remediation includes a comprehensive approach including education, cleaning, physical barriers and maintaining these practices. PMID:20568555
The MAGIC Touch: Combining MAGIC-Pointing with a Touch-Sensitive Mouse
NASA Astrophysics Data System (ADS)
Drewes, Heiko; Schmidt, Albrecht
In this paper, we show how to use the combination of eye-gaze and a touch-sensitive mouse to ease pointing tasks in graphical user interfaces. A touch of the mouse positions the mouse pointer at the current gaze position of the user. Thus, the pointer is always at the position where the user expects it on the screen. This approach changes the user experience in tasks that include frequent switching between keyboard and mouse input (e.g. working with spreadsheets). In a user study, we compared the touch-sensitive mouse with a traditional mouse and observed speed improvements for pointing tasks on complex backgrounds. For pointing task on plain backgrounds, performances with both devices were similar, but users perceived the gaze-sensitive interaction of the touch-sensitive mouse as being faster and more convenient. Our results show that using a touch-sensitive mouse that positions the pointer on the user’s gaze position reduces the need for mouse movements in pointing tasks enormously.
Monitoring Neural Activity with Bioluminescence during Natural Behavior
Naumann, Eva A.; Kampff, Adam R.; Prober, David A.; Schier, Alexander F.; Engert, Florian
2010-01-01
Existing techniques for monitoring neural activity in awake, freely behaving vertebrates are invasive and difficult to target to genetically identified neurons. Here we describe the use of bioluminescence to non-invasively monitor the activity of genetically specified neurons in freely behaving zebrafish. Transgenic fish expressing the Ca2+-sensitive photoprotein GFP-apoAequorin (GA) in most neurons generated large and fast bioluminescent signals related to neural activity, neuroluminescence, that could be recorded continuously for many days. To test the limits of this technique, GA was specifically targeted to the hypocretin-positive neurons of the hypothalamus. We found that neuroluminescence generated by this group of ~20 neurons was associated with periods of increased locomotor activity and identified two classes of neural activity corresponding to distinct swim latencies. Thus, our neuroluminescence assay can report, with high temporal resolution and sensitivity, the activity of small subsets of neurons during unrestrained behavior. PMID:20305645
NASA Astrophysics Data System (ADS)
Abbott, B. P.; Abbott, R.; Abbott, T. D.; Acernese, F.; Ackley, K.; Adams, C.; Adams, T.; Addesso, P.; Adhikari, R. X.; Adya, V. B.; Affeldt, C.; Afrough, M.; Agarwal, B.; Agathos, M.; Agatsuma, K.; Aggarwal, N.; Aguiar, O. D.; Aiello, L.; Ain, A.; Allen, B.; Allen, G.; Allocca, A.; Altin, P. A.; Amato, A.; Ananyeva, A.; Anderson, S. B.; Anderson, W. G.; Angelova, S. V.; Antier, S.; Appert, S.; Arai, K.; Araya, M. C.; Areeda, J. S.; Arnaud, N.; Arun, K. G.; Ascenzi, S.; Ashton, G.; Ast, M.; Aston, S. M.; Astone, P.; Atallah, D. V.; Aufmuth, P.; Aulbert, C.; AultONeal, K.; Austin, C.; Avila-Alvarez, A.; Babak, S.; Bacon, P.; Bader, M. K. M.; Bae, S.; Baker, P. T.; Baldaccini, F.; Ballardin, G.; Ballmer, S. W.; Banagiri, S.; Barayoga, J. C.; Barclay, S. E.; Barish, B. C.; Barker, D.; Barkett, K.; Barone, F.; Barr, B.; Barsotti, L.; Barsuglia, M.; Barta, D.; Bartlett, J.; Bartos, I.; Bassiri, R.; Basti, A.; Batch, J. C.; Bawaj, M.; Bayley, J. C.; Bazzan, M.; Bécsy, B.; Beer, C.; Bejger, M.; Belahcene, I.; Bell, A. S.; Berger, B. K.; Bergmann, G.; Bero, J. J.; Berry, C. P. L.; Bersanetti, D.; Bertolini, A.; Betzwieser, J.; Bhagwat, S.; Bhandare, R.; Bilenko, I. A.; Billingsley, G.; Billman, C. R.; Birch, J.; Birney, R.; Birnholtz, O.; Biscans, S.; Biscoveanu, S.; Bisht, A.; Bitossi, M.; Biwer, C.; Bizouard, M. A.; Blackburn, J. K.; Blackman, J.; Blair, C. D.; Blair, D. G.; Blair, R. M.; Bloemen, S.; Bock, O.; Bode, N.; Boer, M.; Bogaert, G.; Bohe, A.; Bondu, F.; Bonilla, E.; Bonnand, R.; Boom, B. A.; Bork, R.; Boschi, V.; Bose, S.; Bossie, K.; Bouffanais, Y.; Bozzi, A.; Bradaschia, C.; Brady, P. R.; Branchesi, M.; Brau, J. E.; Briant, T.; Brillet, A.; Brinkmann, M.; Brisson, V.; Brockill, P.; Broida, J. E.; Brooks, A. F.; Brown, D. A.; Brown, D. D.; Brunett, S.; Buchanan, C. C.; Buikema, A.; Bulik, T.; Bulten, H. J.; Buonanno, A.; Buskulic, D.; Buy, C.; Byer, R. L.; Cabero, M.; Cadonati, L.; Cagnoli, G.; Cahillane, C.; Calderón Bustillo, J.; Callister, T. A.; Calloni, E.; Camp, J. B.; Canizares, P.; Cannon, K. C.; Cao, H.; Cao, J.; Capano, C. D.; Capocasa, E.; Carbognani, F.; Caride, S.; Carney, M. F.; Casanueva Diaz, J.; Casentini, C.; Caudill, S.; Cavaglià, M.; Cavalier, F.; Cavalieri, R.; Cella, G.; Cepeda, C. B.; Cerdá-Durán, P.; Cerretani, G.; Cesarini, E.; Chamberlin, S. J.; Chan, M.; Chao, S.; Charlton, P.; Chase, E.; Chassande-Mottin, E.; Chatterjee, D.; Cheeseboro, B. D.; Chen, H. Y.; Chen, X.; Chen, Y.; Cheng, H.-P.; Chia, H.; Chincarini, A.; Chiummo, A.; Chmiel, T.; Cho, H. S.; Cho, M.; Chow, J. H.; Christensen, N.; Chu, Q.; Chua, A. J. K.; Chua, S.; Chung, A. K. W.; Chung, S.; Ciani, G.; Ciolfi, R.; Cirelli, C. E.; Cirone, A.; Clara, F.; Clark, J. A.; Clearwater, P.; Cleva, F.; Cocchieri, C.; Coccia, E.; Cohadon, P.-F.; Cohen, D.; Colla, A.; Collette, C. G.; Cominsky, L. R.; Constancio, M.; Conti, L.; Cooper, S. J.; Corban, P.; Corbitt, T. R.; Cordero-Carrión, I.; Corley, K. R.; Cornish, N.; Corsi, A.; Cortese, S.; Costa, C. A.; Coughlin, M. W.; Coughlin, S. B.; Coulon, J.-P.; Countryman, S. T.; Couvares, P.; Covas, P. B.; Cowan, E. E.; Coward, D. M.; Cowart, M. J.; Coyne, D. C.; Coyne, R.; Creighton, J. D. E.; Creighton, T. D.; Cripe, J.; Crowder, S. G.; Cullen, T. J.; Cumming, A.; Cunningham, L.; Cuoco, E.; Dal Canton, T.; Dálya, G.; Danilishin, S. L.; D'Antonio, S.; Danzmann, K.; Dasgupta, A.; Da Silva Costa, C. F.; Dattilo, V.; Dave, I.; Davier, M.; Davis, D.; Daw, E. J.; Day, B.; De, S.; DeBra, D.; Degallaix, J.; De Laurentis, M.; Deléglise, S.; Del Pozzo, W.; Demos, N.; Denker, T.; Dent, T.; De Pietri, R.; Dergachev, V.; De Rosa, R.; DeRosa, R. T.; De Rossi, C.; DeSalvo, R.; de Varona, O.; Devenson, J.; Dhurandhar, S.; Díaz, M. C.; Di Fiore, L.; Di Giovanni, M.; Di Girolamo, T.; Di Lieto, A.; Di Pace, S.; Di Palma, I.; Di Renzo, F.; Doctor, Z.; Dolique, V.; Donovan, F.; Dooley, K. L.; Doravari, S.; Dorrington, I.; Douglas, R.; Dovale Álvarez, M.; Downes, T. P.; Drago, M.; Dreissigacker, C.; Driggers, J. C.; Du, Z.; Ducrot, M.; Dupej, P.; Dwyer, S. E.; Edo, T. B.; Edwards, M. C.; Effler, A.; Eggenstein, H.-B.; Ehrens, P.; Eichholz, J.; Eikenberry, S. S.; Eisenstein, R. A.; Essick, R. C.; Estevez, D.; Etienne, Z. B.; Etzel, T.; Evans, M.; Evans, T. M.; Factourovich, M.; Fafone, V.; Fair, H.; Fairhurst, S.; Fan, X.; Farinon, S.; Farr, B.; Farr, W. M.; Fauchon-Jones, E. J.; Favata, M.; Fays, M.; Fee, C.; Fehrmann, H.; Feicht, J.; Fejer, M. M.; Fernandez-Galiana, A.; Ferrante, I.; Ferreira, E. C.; Ferrini, F.; Fidecaro, F.; Finstad, D.; Fiori, I.; Fiorucci, D.; Fishbach, M.; Fisher, R. P.; Fitz-Axen, M.; Flaminio, R.; Fletcher, M.; Fong, H.; Font, J. A.; Forsyth, P. W. F.; Forsyth, S. S.; Fournier, J.-D.; Frasca, S.; Frasconi, F.; Frei, Z.; Freise, A.; Frey, R.; Frey, V.; Fries, E. M.; Fritschel, P.; Frolov, V. V.; Fulda, P.; Fyffe, M.; Gabbard, H.; Gadre, B. U.; Gaebel, S. M.; Gair, J. R.; Gammaitoni, L.; Ganija, M. R.; Gaonkar, S. G.; Garcia-Quiros, C.; Garufi, F.; Gateley, B.; Gaudio, S.; Gaur, G.; Gayathri, V.; Gehrels, N.; Gemme, G.; Genin, E.; Gennai, A.; George, D.; George, J.; Gergely, L.; Germain, V.; Ghonge, S.; Ghosh, Abhirup; Ghosh, Archisman; Ghosh, S.; Giaime, J. A.; Giardina, K. D.; Giazotto, A.; Gill, K.; Glover, L.; Goetz, E.; Goetz, R.; Gomes, S.; Goncharov, B.; González, G.; Gonzalez Castro, J. M.; Gopakumar, A.; Gorodetsky, M. L.; Gossan, S. E.; Gosselin, M.; Gouaty, R.; Grado, A.; Graef, C.; Granata, M.; Grant, A.; Gras, S.; Gray, C.; Greco, G.; Green, A. C.; Gretarsson, E. M.; Groot, P.; Grote, H.; Grunewald, S.; Gruning, P.; Guidi, G. M.; Guo, X.; Gupta, A.; Gupta, M. K.; Gushwa, K. E.; Gustafson, E. K.; Gustafson, R.; Halim, O.; Hall, B. R.; Hall, E. D.; Hamilton, E. Z.; Hammond, G.; Haney, M.; Hanke, M. M.; Hanks, J.; Hanna, C.; Hannam, M. D.; Hannuksela, O. A.; Hanson, J.; Hardwick, T.; Harms, J.; Harry, G. M.; Harry, I. W.; Hart, M. J.; Haster, C.-J.; Haughian, K.; Healy, J.; Heidmann, A.; Heintze, M. C.; Heitmann, H.; Hello, P.; Hemming, G.; Hendry, M.; Heng, I. S.; Hennig, J.; Heptonstall, A. W.; Heurs, M.; Hild, S.; Hinderer, T.; Ho, W. C. G.; Hoak, D.; Hofman, D.; Holt, K.; Holz, D. E.; Hopkins, P.; Horst, C.; Hough, J.; Houston, E. A.; Howell, E. J.; Hreibi, A.; Hu, Y. M.; Huerta, E. A.; Huet, D.; Hughey, B.; Husa, S.; Huttner, S. H.; Huynh-Dinh, T.; Indik, N.; Inta, R.; Intini, G.; Isa, H. N.; Isac, J.-M.; Isi, M.; Iyer, B. R.; Izumi, K.; Jacqmin, T.; Jani, K.; Jaranowski, P.; Jawahar, S.; Jiménez-Forteza, F.; Johnson, W. W.; Jones, D. I.; Jones, R.; Jonker, R. J. G.; Ju, L.; Junker, J.; Kalaghatgi, C. V.; Kalogera, V.; Kamai, B.; Kandhasamy, S.; Kang, G.; Kanner, J. B.; Kapadia, S. J.; Karki, S.; Karvinen, K. S.; Kasprzack, M.; Katolik, M.; Katsavounidis, E.; Katzman, W.; Kaufer, S.; Kawabe, K.; Kéfélian, F.; Keitel, D.; Kemball, A. J.; Kennedy, R.; Kent, C.; Key, J. S.; Khalili, F. Y.; Khan, I.; Khan, S.; Khan, Z.; Khazanov, E. A.; Kijbunchoo, N.; Kim, Chunglee; Kim, J. C.; Kim, K.; Kim, W.; Kim, W. S.; Kim, Y.-M.; Kimbrell, S. J.; King, E. J.; King, P. J.; Kinley-Hanlon, M.; Kirchhoff, R.; Kissel, J. S.; Kleybolte, L.; Klimenko, S.; Knowles, T. D.; Koch, P.; Koehlenbeck, S. M.; Koley, S.; Kondrashov, V.; Kontos, A.; Korobko, M.; Korth, W. Z.; Kowalska, I.; Kozak, D. B.; Krämer, C.; Kringel, V.; Krishnan, B.; Królak, A.; Kuehn, G.; Kumar, P.; Kumar, R.; Kumar, S.; Kuo, L.; Kutynia, A.; Kwang, S.; Lackey, B. D.; Lai, K. H.; Landry, M.; Lang, R. N.; Lange, J.; Lantz, B.; Lanza, R. K.; Lartaux-Vollard, A.; Lasky, P. D.; Laxen, M.; Lazzarini, A.; Lazzaro, C.; Leaci, P.; Leavey, S.; Lee, C. H.; Lee, H. K.; Lee, H. M.; Lee, H. W.; Lee, K.; Lehmann, J.; Lenon, A.; Leonardi, M.; Leroy, N.; Letendre, N.; Levin, Y.; Li, T. G. F.; Linker, S. D.; Littenberg, T. B.; Liu, J.; Lo, R. K. L.; Lockerbie, N. A.; London, L. T.; Lord, J. E.; Lorenzini, M.; Loriette, V.; Lormand, M.; Losurdo, G.; Lough, J. D.; Lovelace, G.; Lück, H.; Lumaca, D.; Lundgren, A. P.; Lynch, R.; Ma, Y.; Macas, R.; Macfoy, S.; Machenschalk, B.; MacInnis, M.; Macleod, D. M.; Magaña Hernandez, I.; Magaña-Sandoval, F.; Magaña Zertuche, L.; Magee, R. M.; Majorana, E.; Maksimovic, I.; Man, N.; Mandic, V.; Mangano, V.; Mansell, G. L.; Manske, M.; Mantovani, M.; Marchesoni, F.; Marion, F.; Márka, S.; Márka, Z.; Markakis, C.; Markosyan, A. S.; Markowitz, A.; Maros, E.; Marquina, A.; Martelli, F.; Martellini, L.; Martin, I. W.; Martin, R. M.; Martynov, D. V.; Mason, K.; Massera, E.; Masserot, A.; Massinger, T. J.; Masso-Reid, M.; Mastrogiovanni, S.; Matas, A.; Matichard, F.; Matone, L.; Mavalvala, N.; Mazumder, N.; McCarthy, R.; McClelland, D. E.; McCormick, S.; McCuller, L.; McGuire, S. C.; McIntyre, G.; McIver, J.; McManus, D. J.; McNeill, L.; McRae, T.; McWilliams, S. T.; Meacher, D.; Meadors, G. D.; Mehmet, M.; Meidam, J.; Mejuto-Villa, E.; Melatos, A.; Mendell, G.; Mercer, R. A.; Merilh, E. L.; Merzougui, M.; Meshkov, S.; Messenger, C.; Messick, C.; Metzdorff, R.; Meyers, P. M.; Miao, H.; Michel, C.; Middleton, H.; Mikhailov, E. E.; Milano, L.; Miller, A. L.; Miller, B. B.; Miller, J.; Millhouse, M.; Milovich-Goff, M. C.; Minazzoli, O.; Minenkov, Y.; Ming, J.; Mishra, C.; Mitra, S.; Mitrofanov, V. P.; Mitselmakher, G.; Mittleman, R.; Moffa, D.; Moggi, A.; Mogushi, K.; Mohan, M.; Mohapatra, S. R. P.; Montani, M.; Moore, C. J.; Moraru, D.; Moreno, G.; Morriss, S. R.; Mours, B.; Mow-Lowry, C. M.; Mueller, G.; Muir, A. W.; Mukherjee, Arunava; Mukherjee, D.; Mukherjee, S.; Mukund, N.; Mullavey, A.; Munch, J.; Muñiz, E. A.; Muratore, M.; Murray, P. G.; Napier, K.; Nardecchia, I.; Naticchioni, L.; Nayak, R. K.; Neilson, J.; Nelemans, G.; Nelson, T. J. N.; Nery, M.; Neunzert, A.; Nevin, L.; Newport, J. M.; Newton, G.; Ng, K. K. Y.; Nguyen, T. T.; Nichols, D.; Nielsen, A. B.; Nissanke, S.; Nitz, A.; Noack, A.; Nocera, F.; Nolting, D.; North, C.; Nuttall, L. K.; Oberling, J.; O'Dea, G. D.; Ogin, G. H.; Oh, J. J.; Oh, S. H.; Ohme, F.; Okada, M. A.; Oliver, M.; Oppermann, P.; Oram, Richard J.; O'Reilly, B.; Ormiston, R.; Ortega, L. F.; O'Shaughnessy, R.; Ossokine, S.; Ottaway, D. J.; Overmier, H.; Owen, B. J.; Pace, A. E.; Page, J.; Page, M. A.; Pai, A.; Pai, S. A.; Palamos, J. R.; Palashov, O.; Palomba, C.; Pal-Singh, A.; Pan, Howard; Pan, Huang-Wei; Pang, B.; Pang, P. T. H.; Pankow, C.; Pannarale, F.; Pant, B. C.; Paoletti, F.; Paoli, A.; Papa, M. A.; Parida, A.; Parker, W.; Pascucci, D.; Pasqualetti, A.; Passaquieti, R.; Passuello, D.; Patil, M.; Patricelli, B.; Pearlstone, B. L.; Pedraza, M.; Pedurand, R.; Pekowsky, L.; Pele, A.; Penn, S.; Perez, C. J.; Perreca, A.; Perri, L. M.; Pfeiffer, H. P.; Phelps, M.; Piccinni, O. J.; Pichot, M.; Piergiovanni, F.; Pierro, V.; Pillant, G.; Pinard, L.; Pinto, I. M.; Pirello, M.; Pitkin, M.; Poe, M.; Poggiani, R.; Popolizio, P.; Porter, E. K.; Post, A.; Powell, J.; Prasad, J.; Pratt, J. W. W.; Pratten, G.; Predoi, V.; Prestegard, T.; Prijatelj, M.; Principe, M.; Privitera, S.; Prodi, G. A.; Prokhorov, L. G.; Puncken, O.; Punturo, M.; Puppo, P.; Pürrer, M.; Qi, H.; Quetschke, V.; Quintero, E. A.; Quitzow-James, R.; Raab, F. J.; Rabeling, D. S.; Radkins, H.; Raffai, P.; Raja, S.; Rajan, C.; Rajbhandari, B.; Rakhmanov, M.; Ramirez, K. E.; Ramos-Buades, A.; Rapagnani, P.; Raymond, V.; Razzano, M.; Read, J.; Regimbau, T.; Rei, L.; Reid, S.; Reitze, D. H.; Ren, W.; Reyes, S. D.; Ricci, F.; Ricker, P. M.; Rieger, S.; Riles, K.; Rizzo, M.; Robertson, N. A.; Robie, R.; Robinet, F.; Rocchi, A.; Rolland, L.; Rollins, J. G.; Roma, V. J.; Romano, R.; Romel, C. L.; Romie, J. H.; Rosińska, D.; Ross, M. P.; Rowan, S.; Rüdiger, A.; Ruggi, P.; Rutins, G.; Ryan, K.; Sachdev, S.; Sadecki, T.; Sadeghian, L.; Sakellariadou, M.; Salconi, L.; Saleem, M.; Salemi, F.; Samajdar, A.; Sammut, L.; Sampson, L. M.; Sanchez, E. J.; Sanchez, L. E.; Sanchis-Gual, N.; Sandberg, V.; Sanders, J. R.; Sassolas, B.; Sathyaprakash, B. S.; Saulson, P. R.; Sauter, O.; Savage, R. L.; Sawadsky, A.; Schale, P.; Scheel, M.; Scheuer, J.; Schmidt, J.; Schmidt, P.; Schnabel, R.; Schofield, R. M. S.; Schönbeck, A.; Schreiber, E.; Schuette, D.; Schulte, B. W.; Schutz, B. F.; Schwalbe, S. G.; Scott, J.; Scott, S. M.; Seidel, E.; Sellers, D.; Sengupta, A. S.; Sentenac, D.; Sequino, V.; Sergeev, A.; Shaddock, D. A.; Shaffer, T. J.; Shah, A. A.; Shahriar, M. S.; Shaner, M. B.; Shao, L.; Shapiro, B.; Shawhan, P.; Sheperd, A.; Shoemaker, D. H.; Shoemaker, D. M.; Siellez, K.; Siemens, X.; Sieniawska, M.; Sigg, D.; Silva, A. D.; Singer, L. P.; Singh, A.; Singhal, A.; Sintes, A. M.; Slagmolen, B. J. J.; Smith, B.; Smith, J. R.; Smith, R. J. E.; Somala, S.; Son, E. J.; Sonnenberg, J. A.; Sorazu, B.; Sorrentino, F.; Souradeep, T.; Spencer, A. P.; Srivastava, A. K.; Staats, K.; Staley, A.; Steinke, M.; Steinlechner, J.; Steinlechner, S.; Steinmeyer, D.; Stevenson, S. P.; Stone, R.; Stops, D. J.; Strain, K. A.; Stratta, G.; Strigin, S. E.; Strunk, A.; Sturani, R.; Stuver, A. L.; Summerscales, T. Z.; Sun, L.; Sunil, S.; Suresh, J.; Sutton, P. J.; Swinkels, B. L.; Szczepańczyk, M. J.; Tacca, M.; Tait, S. C.; Talbot, C.; Talukder, D.; Tanner, D. B.; Tápai, M.; Taracchini, A.; Tasson, J. D.; Taylor, J. A.; Taylor, R.; Tewari, S. V.; Theeg, T.; Thies, F.; Thomas, E. G.; Thomas, M.; Thomas, P.; Thorne, K. A.; Thrane, E.; Tiwari, S.; Tiwari, V.; Tokmakov, K. V.; Toland, K.; Tonelli, M.; Tornasi, Z.; Torres-Forné, A.; Torrie, C. I.; Töyrä, D.; Travasso, F.; Traylor, G.; Trinastic, J.; Tringali, M. C.; Trozzo, L.; Tsang, K. W.; Tse, M.; Tso, R.; Tsukada, L.; Tsuna, D.; Tuyenbayev, D.; Ueno, K.; Ugolini, D.; Unnikrishnan, C. S.; Urban, A. L.; Usman, S. A.; Vahlbruch, H.; Vajente, G.; Valdes, G.; van Bakel, N.; van Beuzekom, M.; van den Brand, J. F. J.; Van Den Broeck, C.; Vander-Hyde, D. C.; van der Schaaf, L.; van Heijningen, J. V.; van Veggel, A. A.; Vardaro, M.; Varma, V.; Vass, S.; Vasúth, M.; Vecchio, A.; Vedovato, G.; Veitch, J.; Veitch, P. J.; Venkateswara, K.; Venugopalan, G.; Verkindt, D.; Vetrano, F.; Viceré, A.; Viets, A. D.; Vinciguerra, S.; Vine, D. J.; Vinet, J.-Y.; Vitale, S.; Vo, T.; Vocca, H.; Vorvick, C.; Vyatchanin, S. P.; Wade, A. R.; Wade, L. E.; Wade, M.; Walet, R.; Walker, M.; Wallace, L.; Walsh, S.; Wang, G.; Wang, H.; Wang, J. Z.; Wang, W. H.; Wang, Y. F.; Ward, R. L.; Warner, J.; Was, M.; Watchi, J.; Weaver, B.; Wei, L.-W.; Weinert, M.; Weinstein, A. J.; Weiss, R.; Wen, L.; Wessel, E. K.; Weßels, P.; Westerweck, J.; Westphal, T.; Wette, K.; Whelan, J. T.; Whiting, B. F.; Whittle, C.; Wilken, D.; Williams, D.; Williams, R. D.; Williamson, A. R.; Willis, J. L.; Willke, B.; Wimmer, M. H.; Winkler, W.; Wipf, C. C.; Wittel, H.; Woan, G.; Woehler, J.; Wofford, J.; Wong, K. W. K.; Worden, J.; Wright, J. L.; Wu, D. S.; Wysocki, D. M.; Xiao, S.; Yamamoto, H.; Yancey, C. C.; Yang, L.; Yap, M. J.; Yazback, M.; Yu, Hang; Yu, Haocun; Yvert, M.; ZadroŻny, A.; Zanolin, M.; Zelenova, T.; Zendri, J.-P.; Zevin, M.; Zhang, L.; Zhang, M.; Zhang, T.; Zhang, Y.-H.; Zhao, C.; Zhou, M.; Zhou, Z.; Zhu, S. J.; Zhu, X. J.; Zucker, M. E.; Zweizig, J.; LIGO Scientific Collaboration; Virgo Collaboration
2017-12-01
Spinning neutron stars asymmetric with respect to their rotation axis are potential sources of continuous gravitational waves for ground-based interferometric detectors. In the case of known pulsars a fully coherent search, based on matched filtering, which uses the position and rotational parameters obtained from electromagnetic observations, can be carried out. Matched filtering maximizes the signal-to-noise (SNR) ratio, but a large sensitivity loss is expected in case of even a very small mismatch between the assumed and the true signal parameters. For this reason, narrow-band analysis methods have been developed, allowing a fully coherent search for gravitational waves from known pulsars over a fraction of a hertz and several spin-down values. In this paper we describe a narrow-band search of 11 pulsars using data from Advanced LIGO's first observing run. Although we have found several initial outliers, further studies show no significant evidence for the presence of a gravitational wave signal. Finally, we have placed upper limits on the signal strain amplitude lower than the spin-down limit for 5 of the 11 targets over the bands searched; in the case of J1813-1749 the spin-down limit has been beaten for the first time. For an additional 3 targets, the median upper limit across the search bands is below the spin-down limit. This is the most sensitive narrow-band search for continuous gravitational waves carried out so far.
Transient re-emergence of oil of turpentine allergy in the pottery industry.
Lear, J T; Heagerty, A H; Tan, B B; Smith, A G; English, J S
1996-09-01
Allergy to oil of turpentine has diminished largely due to the use of cheaper substitutes in many occupations. However, 2 particular areas still reliant on real oil of turpentine are those of the perfume industry and ceramic decoration. We report 24 cases of hand dermatitis in pottery workers involved in ceramic decoration, paintresses, liners, gilders, enamellers and a fine china painter, seen in a 6-month period following a change from Portuguese to Indonesian turpentine, of whom 14 were sensitive to Indonesian turpentine, 8 to alpha-pinene, 4 to delta-3-carene and 2 positive to turpentine peroxides. Previous reports suggest that delta-3-carene is the main allergen and reports of sensitivity to alpha-pinene in the absence of sensitivity to turpentine peroxide, in particular to the hydroperoxide of delta-3-carene, are few. Turpentine allergy continues to be a problem in the pottery industry and is more common than allergy to the heavy metals of the colours used in ceramic decoration. alpha-Pinene, an unusual allergen, appears to be the most common in our area. Reversion to Portuguese turpentine seems to have alleviated the problem.
Frey, T; Newlin, L L; Atherly, A G
1975-01-01
A mutant of Escherichia coli has been isolated that has a temperature-sensitive mutation that results in specific loss of ribosomal ribonucleic acid (RNA) synthesis and some reduction in messenger RNA synthesis. When the strain was grown in glucose medium at a restrictive temperature, RNA accumulation ceased, but both messenger RNA and protein synthesis continued for an extended time. Because carbon metabolism was slowed drastically when strain AA-157 was placed at the restrictive temperature, this phenotype can be compared with carbon depletion conditions present during diauxic lag. However, the phenotype of mutant AA-157 differs from shift-down conditions in that guanosine-3',5'-tetraphosphate levels are unaffected; therefore, a different site is affected. This mutant strain (AA-157) thus shows many characteristics similar to an aldolase mutant previously reported (Böck and Neidhardt, 1966). However, the mutation occurred in a different position on the E. coli genetic map, and furthermore, aldolase was not temperature sensitive in strain AA-157. In this paper we present a study of macromolecular biosynthesis in this mutant. PMID:1090609
Gengsheng Qin; Davis, Angela E; Jing, Bing-Yi
2011-06-01
For a continuous-scale diagnostic test, it is often of interest to find the range of the sensitivity of the test at the cut-off that yields a desired specificity. In this article, we first define a profile empirical likelihood ratio for the sensitivity of a continuous-scale diagnostic test and show that its limiting distribution is a scaled chi-square distribution. We then propose two new empirical likelihood-based confidence intervals for the sensitivity of the test at a fixed level of specificity by using the scaled chi-square distribution. Simulation studies are conducted to compare the finite sample performance of the newly proposed intervals with the existing intervals for the sensitivity in terms of coverage probability. A real example is used to illustrate the application of the recommended methods.
Shankar, Nisha; Daly, Richard; Geske, Jennifer; Kushwaha, Sudhir K; Timmons, Michael; Joyce, Lyle; Stulak, John; Gandhi, Manish; Kremers, Walter; Park, Soon; Pereira, Naveen L
2013-01-01
Background Left ventricular assist devices (LVAD) as a bridge (BTT) to heart transplantation (HTX) may be limited by the formation of anti-HLA antibodies. Whether sensitization occurs with continuous axial flow LVAD implant as assessed by Single Antigen Bead (SAB) assay is unknown. Methods Cytotoxic panel reactive antibody (PRA) and SAB assays were analyzed in HTX recipients undergoing LVAD implant as a BTT. Sensitization was defined as peak anti-HLA antibody values of >2000 mean fluorescent intensity as these values have been found to correlate with flow cytometric crossmatch results. Results LVADs were implanted as BTT in 30 patients. There were 7% (2/30) of patients prior to and no patients after LVAD implant with PRA >10%. However, 20% (6/30) of patients prior to and 53% (16/30) after LVAD were sensitized as measured by SAB (p=0.024). At HTX, 47% (14/30) of patients remained sensitized. A positive virtual crossmatch was observed in 28% (4/14) of the sensitized patients at HTX. There was no difference between the sensitized and non-sensitized groups (p>0.4 for all) in usage of blood products (64 11 vs. 63 39 units), time to HTX (286 63 vs. 257 48 days) and 1 year after HTX, there were no differences in rejection (total rejection score 0.30 vs. 0.37) and survival (93% vs. 88%). Conclusion Allosensitization after LVAD is common despite cytotoxic PRA being negative. One year after HTX, this sensitization does not translate into increased acute cellular or antibody mediated rejection or reduced survival. PMID:23743727
Breastfeeding and its relation to maternal sensitivity and infant attachment.
Tharner, Anne; Luijk, Maartje P C M; Raat, Hein; Ijzendoorn, Marinus H; Bakermans-Kranenburg, Marian J; Moll, Henriette A; Jaddoe, Vincent W V; Hofman, Albert; Verhulst, Frank C; Tiemeier, Henning
2012-06-01
To examine the association of breastfeeding with maternal sensitive responsiveness and infant-mother attachment security and disorganization. We included 675 participants of a prospective cohort study. Questionnaires about breastfeeding practices were administered at 2 and 6 months postpartum. At 14 months, maternal sensitive responsiveness was assessed in a 13-minute laboratory procedure using Ainsworth's sensitivity scales, and attachment quality was assessed with the Strange Situation Procedure. Mothers were genotyped for oxytocin receptor genes OXTR rs53576 and OXTR rs2254298. Linear regressions and analyses of covariance adjusted for various background variables were conducted. We tested for mediation and moderation by maternal sensitive responsiveness and maternal oxytocin receptor genotype. Continuous analyses showed that longer duration of breastfeeding was associated with more maternal sensitive responsiveness (B = 0.11, 95% confidence interval [CI] 0.02; 0.20, p < .05), more attachment security (B = 0.24, 95% CI = 0.02; 0.46, p < .05), and less attachment disorganization (B = -0.20, 95% CI -0.36; -0.03, p < .05). Duration of breastfeeding was not related to the risk of insecure-avoidant or insecure-resistant versus secure attachment classification, but longer duration of breastfeeding predicted a lower risk of disorganized versus secure attachment classification (n = 151; odds ratio [OR] = 0.81, 95% CI 0.66 to 0.99, p = .04). Maternal sensitive responsiveness did not mediate the associations, and maternal oxytocin receptor genotype was not a significant moderator. Although duration of breastfeeding was not associated with differences in infant-mother attachment classifications, we found subtle positive associations between duration of breastfeeding and sensitive responsiveness, attachment security, and disorganization.
NASA Astrophysics Data System (ADS)
Levesque, M.
Artificial satellites, and particularly space junk, drift continuously from their known orbits. In the surveillance-of-space context, they must be observed frequently to ensure that the corresponding orbital parameter database entries are up-to-date. Autonomous ground-based optical systems are periodically tasked to observe these objects, calculate the difference between their predicted and real positions and update object orbital parameters. The real satellite positions are provided by the detection of the satellite streaks in the astronomical images specifically acquired for this purpose. This paper presents the image processing techniques used to detect and extract the satellite positions. The methodology includes several processing steps including: image background estimation and removal, star detection and removal, an iterative matched filter for streak detection, and finally false alarm rejection algorithms. This detection methodology is able to detect very faint objects. Simulated data were used to evaluate the methodology's performance and determine the sensitivity limits where the algorithm can perform detection without false alarm, which is essential to avoid corruption of the orbital parameter database.
Collaboration can improve individual recognition memory: evidence from immediate and delayed tests.
Rajaram, Suparna; Pereira-Pasarin, Luciane P
2007-02-01
In two experiments, we tested the effects of collaboration on individual recognition memory. In Experiment 1, participants studied pictures and words either for meaning or for surface properties and made recognition memory judgments individually either following group discussion among 3 members (collaborative condition) or in the absence of discussion (noncollaborative condition). Levels of processing and picture superiority effects were replicated, and collaboration significantly increased individual recognition memory. Experiment 2 replicated this positive effect and showed that even though memory sensitivity declined at longer delays (48 h and 1 week), collaboration continued to exert a positive influence. These findings show that (1) consensus is not necessary for producing benefits of collaboration on individual recognition, (2) collaborative facilitation on individual memory is robust, and (3) collaboration enhances individual memory further if conditions predispose individual accuracy in the absence of collaboration.
Interoceptive contributions to healthy eating and obesity.
Simmons, W Kyle; DeVille, Danielle C
2017-10-01
Obesity results from persistent failure by the brain to balance food intake with energy needs, resulting in a state of chronic energy surplus. Although there are many factors that predispose individuals to weight gain and obesity, the current review focuses on two ways eating behavior may be influenced by sensitivity to interoceptive signals of hunger, satiety, and metabolic energy reserves. First, obesity may be related to hypersensitivity to interoceptive signals of hunger, leading to positive alliesthesia for food cues that undermine attempts to change unhealthy eating behaviors. Second, overeating and obesity may arise from an inability to accurately detect interoceptive signals of satiety and positive energy balance. The findings reviewed herein demonstrate that obesity may be related to altered interoception, and warrant the continued development of novel obesity interventions aimed at promoting interoceptive awareness. Copyright © 2017 Elsevier Ltd. All rights reserved.
I Don’t Want to Come Back Down: Undoing versus Maintaining of Reward Recovery in Older Adolescents
Gilbert, Kirsten E.; Nolen-Hoeksema, Susan; Gruber, June
2017-01-01
Adolescence is characterized by heightened and sometimes impairing reward sensitivity, yet less is known about how adolescents recover from highly arousing positive states. This is particularly important given high onset rates of psychopathology associated with reward sensitivity during late adolescence and early adulthood. The current study thus utilized a novel reward sensitivity task in order to examine potential ways in which older adolescent females (ages 18–21; N = 83) might recover from high arousal positive reward sensitive states. Participants underwent a fixed incentive reward sensitivity task and subsequently watched a neutral, sad, or a low approach-motivated positive emotional film clip during which subjective and physiological recovery was assessed. Results indicated that the positive and negative film conditions were associated with maintained physiological arousal while the neutral condition facilitated faster physiological recovery from the reward sensitivity task. Interestingly, individual differences in self-reported positive emotion during the reward task were associated with faster recovery in the neutral condition. Findings suggest elicited emotion (regardless of valence) may serve to maintain reward sensitivity while self-reported positive emotional experience may be a key ingredient facilitating physiological recovery or undoing. Understanding the nuances of reward recovery provides a critical step in understanding the etiology and persistence of reward dysregulation more generally. PMID:26595439
Measuring momentum for charged particle tomography
Morris, Christopher; Fraser, Andrew Mcleod; Schultz, Larry Joe; Borozdin, Konstantin N.; Klimenko, Alexei Vasilievich; Sossong, Michael James; Blanpied, Gary
2010-11-23
Methods, apparatus and systems for detecting charged particles and obtaining tomography of a volume by measuring charged particles including measuring the momentum of a charged particle passing through a charged particle detector. Sets of position sensitive detectors measure scattering of the charged particle. The position sensitive detectors having sufficient mass to cause the charged particle passing through the position sensitive detectors to scatter in the position sensitive detectors. A controller can be adapted and arranged to receive scattering measurements of the charged particle from the charged particle detector, determine at least one trajectory of the charged particle from the measured scattering; and determine at least one momentum measurement of the charged particle from the at least one trajectory. The charged particle can be a cosmic ray-produced charged particle, such as a cosmic ray-produced muon. The position sensitive detectors can be drift cells, such as gas-filled drift tubes.
Sutter, Martin A.; Grob, Dieter; Jeszenszky, Dezsö; Porchet, François; Dvorak, Jiri
2007-01-01
A prospective study of 246 patients who received multimodal intraoperative monitoring during cervical spine surgery between March 2000 and December 2005. To determine the sensitivity and specificity of MIOM techniques used to monitor spinal cord and nerve root function during cervical spine surgery. It is appreciated that complication rate of cervical spine surgery is low, however, there is a significant risk of neurological injury. The combination of monitoring of ascending and descending pathways may provide more sensitive and specific results giving immediate feedback information and/or alert regarding any neurological changes during the operation to the surgeon. Intraoperative somatosensory spinal and cerebral evoked potentials combined with continuous EMG and motor-evoked potentials of the spinal cord and muscles were evaluated and compared with postoperative clinical neurological changes. A total of 246 consecutive patients with cervical pathologies, majority spinal stenosis due to degenerative changes of cervical spine were monitored by means of MIOM during the surgical procedure. About 232 patients presented true negative while 2 patients false negative responses. About ten patients presented true positive responses where neurological deficit after the operation was predicted and two patients presented false positive findings. The sensitivity of MIOM applied during cervical spine procedure (anterior and/or posterior) was 83.3% and specificity of 99.2%. MIOM is an effective method of monitoring the spinal cord functional integrity during cervical spine surgery and can help to reduce the risk of neurological deficit by alerting the surgeon when monitoring changes are observed. PMID:17610090
Nasrallah, Fatima A; Lee, Eugene L Q; Chuang, Kai-Hsiang
2012-11-01
Arterial spin labeling (ASL) MRI provides a noninvasive method to image perfusion, and has been applied to map neural activation in the brain. Although pulsed labeling methods have been widely used in humans, continuous ASL with a dedicated neck labeling coil is still the preferred method in rodent brain functional MRI (fMRI) to maximize the sensitivity and allow multislice acquisition. However, the additional hardware is not readily available and hence its application is limited. In this study, flow-sensitive alternating inversion recovery (FAIR) pulsed ASL was optimized for fMRI of rat brain. A practical challenge of FAIR is the suboptimal global inversion by the transmit coil of limited dimensions, which results in low effective labeling. By using a large volume transmit coil and proper positioning to optimize the body coverage, the perfusion signal was increased by 38.3% compared with positioning the brain at the isocenter. An additional 53.3% gain in signal was achieved using optimized repetition and inversion times compared with a long TR. Under electrical stimulation to the forepaws, a perfusion activation signal change of 63.7 ± 6.3% can be reliably detected in the primary somatosensory cortices using single slice or multislice echo planar imaging at 9.4 T. This demonstrates the potential of using pulsed ASL for multislice perfusion fMRI in functional and pharmacological applications in rat brain. Copyright © 2012 John Wiley & Sons, Ltd.
Deborggraeve, Stijn; Lejon, Veerle; Ekangu, Rosine Ali; Mumba Ngoyi, Dieudonné; Pati Pyana, Patient; Ilunga, Médard; Mulunda, Jean Pierre; Büscher, Philippe
2011-02-22
The polymerase chain reaction (PCR) has been proposed for diagnosis, staging and post-treatment follow-up of sleeping sickness but no large-scale clinical evaluations of its diagnostic accuracy have taken place yet. An 18S ribosomal RNA gene targeting PCR was performed on blood and cerebrospinal fluid (CSF) of 360 T. brucei gambiense sleeping sickness patients and on blood of 129 endemic controls from the Democratic Republic of Congo. Sensitivity and specificity (with 95% confidence intervals) of PCR for diagnosis, disease staging and treatment failure over 2 years follow-up post-treatment were determined. Reference standard tests were trypanosome detection for diagnosis and trypanosome detection and/or increased white blood cell concentration in CSF for staging and detection of treatment failure. PCR on blood showed a sensitivity of 88.4% (84.4-92.5%) and a specificity of 99.2% (97.7-100%) for diagnosis, while for disease staging the sensitivity and specificity of PCR on cerebrospinal fluid were 88.4% (84.8-91.9%) and 82.9% (71.2-94.6%), respectively. During follow-up after treatment, PCR on blood had low sensitivity to detect treatment failure. In cerebrospinal fluid, PCR positivity vanished slowly and was observed until the end of the 2 year follow-up in around 20% of successfully treated patients. For T.b. gambiense sleeping sickness diagnosis and staging, PCR performed better than, or similar to, the current parasite detection techniques but it cannot be used for post-treatment follow-up. Continued PCR positivity in one out of five cured patients points to persistence of living or dead parasites or their DNA after successful treatment and may necessitate the revision of some paradigms about the pathophysiology of sleeping sickness.
Position-sensitive, fast ionization chambers
NASA Astrophysics Data System (ADS)
Lai, J.; Afanasieva, L.; Blackmon, J. C.; Deibel, C. M.; Gardiner, H. E.; Lauer, A.; Linhardt, L. E.; Macon, K. T.; Rasco, B. C.; Williams, C.; Santiago-Gonzalez, D.; Kuvin, S. A.; Almaraz-Calderon, S.; Baby, L. T.; Baker, J.; Belarge, J.; Wiedenhöver, I.; Need, E.; Avila, M. L.; Back, B. B.; DiGiovine, B.; Hoffman, C. R.
2018-05-01
A high-count-rate ionization chamber design with position-sensitivity has been developed and deployed at several accelerator facilities. Counting rates of ≥ 500 kHz with good Z-separation (up to 5% energy resolution) for particle identification have been demonstrated in a series of commissioning experiments. A position-sensitive capability, with a resolution of 3 mm, has been implemented for the first time to record position information and suppress pileup. The design and performance of the detectors are described.
Wang, X Y; Ning, H Y; Chu, S M; Jiang, L; Pang, Y J; Jin, W T; Wang, S Q; Wang, X Y
2017-12-05
Objective: To explore the feature of allergic sensitization of tree pollen and the relationship between tree pollen and airborne pollen in Beijing. Method: Two thousand five hundred and twenty-one patients with allergic diseases were enrolled between January to July in 2017 in an allergy department. All patients received SPT of 8 kinds of tree pollen. Result: ①The overall tree pollen positive rate of SPT was 49.3% (1 244/2 521). Male had a higher positive rate than female (56.4% vs 45.0%, P <0.01) while child group had a higher positive rate than adult group (55.9% vs 48.6%, P <0.05). The poly sensitization was observed with a rate of 26.3%, take the percentage of 53.3% of the overall positive subjects. ②The highest sensitization rate was found in March (62.2%), followed by May (52.1%), the lowest was January (27.9%). There was a positive correlation between tree pollen sensitization rate and pollen count of each month ( r =0.929, P <0.01). ③Cypress had the highest positive rate (34.6%), followed by poplar (21.3%), the lowest was sophora (13.3%). The sensitization rate was positively correlated with pollen count among different tree pollen ( r =0.714, P <0.05). Conclusion: The main allergic pollen in Beijing was cypress. The tree pollen sensitization showed a seasonality with the peak in March. The sensitization status was tightly associated with the amount of airborne pollen. Copyright© by the Editorial Department of Journal of Clinical Otorhinolaryngology Head and Neck Surgery.
The sensitivity of the QuantiFERON®-TB Gold Plus assay in Zambian adults with active tuberculosis.
Telisinghe, L; Amofa-Sekyi, M; Maluzi, K; Kaluba-Milimo, D; Cheeba-Lengwe, M; Chiwele, K; Kosloff, B; Floyd, S; Bailey, S-L; Ayles, H
2017-06-01
To investigate the sensitivity of the new interferon-gamma release assay (IGRA), QuantiFERON®-TB Gold Plus (QFT-Plus), for active TB (used as a surrogate for latent tuberculous infection) in a Zambian TB clinic. Consecutive smear or Xpert® MTB/RIF-positive adult (age 18 years) pulmonary TB patients were recruited between June 2015 and March 2016. Venous blood was tested using QFT-Plus. The sensitivity was defined as the number positive divided by the total number tested. Using logistic regression, factors associated with positive QFT-Plus results were explored. Of 108 patients (median age 32 years, interquartile range 27-38; 73% male; 63% human immunodeficiency virus [HIV] positive), 90 were QFT-Plus-positive, 11 were negative and seven had indeterminate results; sensitivity was 83% (95%CI 75-90). There was no difference in sensitivity by HIV status (HIV-positive 85%, 95%CI 75-93; n = 68 vs. HIV-negative 80%, 95%CI 64-91; n = 40; P = 0.59). In models adjusted for age alone, CD4 cell count <100 cells/μl (OR 0.15, 95%CI 0.02-0.96; P = 0.05) and body mass index <18.5 kg/m2 (OR 0.27, 95%CI 0.08-0.91; P = 0.02) were associated with decreased odds of positive QFT-Plus results. Overall, the sensitivity of QFT-Plus is similar to that of the tuberculin skin test and other IGRAs. While overall sensitivity is not affected by HIV status, QFT-Plus sensitivity was lower among people living with HIV/acquired immune-deficiency syndrome with severe immunosuppression.
Bayesian functional integral method for inferring continuous data from discrete measurements.
Heuett, William J; Miller, Bernard V; Racette, Susan B; Holloszy, John O; Chow, Carson C; Periwal, Vipul
2012-02-08
Inference of the insulin secretion rate (ISR) from C-peptide measurements as a quantification of pancreatic β-cell function is clinically important in diseases related to reduced insulin sensitivity and insulin action. ISR derived from C-peptide concentration is an example of nonparametric Bayesian model selection where a proposed ISR time-course is considered to be a "model". An inferred value of inaccessible continuous variables from discrete observable data is often problematic in biology and medicine, because it is a priori unclear how robust the inference is to the deletion of data points, and a closely related question, how much smoothness or continuity the data actually support. Predictions weighted by the posterior distribution can be cast as functional integrals as used in statistical field theory. Functional integrals are generally difficult to evaluate, especially for nonanalytic constraints such as positivity of the estimated parameters. We propose a computationally tractable method that uses the exact solution of an associated likelihood function as a prior probability distribution for a Markov-chain Monte Carlo evaluation of the posterior for the full model. As a concrete application of our method, we calculate the ISR from actual clinical C-peptide measurements in human subjects with varying degrees of insulin sensitivity. Our method demonstrates the feasibility of functional integral Bayesian model selection as a practical method for such data-driven inference, allowing the data to determine the smoothing timescale and the width of the prior probability distribution on the space of models. In particular, our model comparison method determines the discrete time-step for interpolation of the unobservable continuous variable that is supported by the data. Attempts to go to finer discrete time-steps lead to less likely models. Copyright © 2012 Biophysical Society. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hull, Carter D.
A position sensitive neutron detector was designed and fabricated with bundles of individual detector elements with diameters of 120 mm. These neutron scintillating fibers were coupled with optoelectronic arrays to produce a ''Fiber Detector.'' A fiber position sensitive detector was completed and tested with scattered and thermal neutrons. Deployment of improved 2D PSDs with high signal to noise ratios at lower costs per area was the overall objective of the project.
Mehta, Milap; Tserentsoodol, Nomingerel; Postlethwait, John H.; Rebrik, Tatiana I.
2013-01-01
The ligand sensitivity of cGMP-gated (CNG) ion channels in cone photoreceptors is modulated by CNG-modulin, a Ca2+-binding protein. We investigated the functional role of CNG-modulin in phototransduction in vivo in morpholino-mediated gene knockdown zebrafish. Through comparative genomic analysis, we identified the orthologue gene of CNG-modulin in zebrafish, eml1, an ancient gene present in the genome of all vertebrates sequenced to date. We compare the photoresponses of wild-type cones with those of cones that do not express the EML1 protein. In the absence of EML1, dark-adapted cones are ∼5.3-fold more light sensitive than wild-type cones. Previous qualitative studies in several nonmammalian species have shown that immediately after the onset of continuous illumination, cones are less light sensitive than in darkness, but sensitivity then recovers over the following 15–20 s. We characterize light sensitivity recovery in continuously illuminated wild-type zebrafish cones and demonstrate that sensitivity recovery does not occur in the absence of EML1. PMID:24198367
Korenbrot, Juan I; Mehta, Milap; Tserentsoodol, Nomingerel; Postlethwait, John H; Rebrik, Tatiana I
2013-11-06
The ligand sensitivity of cGMP-gated (CNG) ion channels in cone photoreceptors is modulated by CNG-modulin, a Ca(2+)-binding protein. We investigated the functional role of CNG-modulin in phototransduction in vivo in morpholino-mediated gene knockdown zebrafish. Through comparative genomic analysis, we identified the orthologue gene of CNG-modulin in zebrafish, eml1, an ancient gene present in the genome of all vertebrates sequenced to date. We compare the photoresponses of wild-type cones with those of cones that do not express the EML1 protein. In the absence of EML1, dark-adapted cones are ∼5.3-fold more light sensitive than wild-type cones. Previous qualitative studies in several nonmammalian species have shown that immediately after the onset of continuous illumination, cones are less light sensitive than in darkness, but sensitivity then recovers over the following 15-20 s. We characterize light sensitivity recovery in continuously illuminated wild-type zebrafish cones and demonstrate that sensitivity recovery does not occur in the absence of EML1.
Groen, Yvonne; Tucha, Oliver; Wijers, Albertus A.; Althaus, Monika
2013-01-01
Objectives Current models of ADHD suggest abnormal reward and punishment sensitivity, but the exact mechanisms are unclear. This study aims to investigate effects of continuous reward and punishment on the processing of performance feedback in children with ADHD and the modulating effects of stimulant medication. Methods 15 Methylphenidate (Mph)-treated and 15 Mph-free children of the ADHD-combined type and 17 control children performed a selective attention task with three feedback conditions: no-feedback, gain and loss. Event Related Potentials (ERPs) time-locked to feedback and errors were computed. Results All groups performed more accurately with gain and loss than without feedback. Feedback-related ERPs demonstrated no group differences in the feedback P2, but an enhanced late positive potential (LPP) to feedback stimuli (both gains and losses) for Mph-free children with ADHD compared to controls. Feedback-related ERPs in Mph-treated children with ADHD were similar to controls. Correlational analyses in the ADHD groups revealed that the severity of inattention problems correlated negatively with the feedback P2 amplitude and positively with the LPP to losses and omitted gains. Conclusions The early selective attention for rewarding and punishing feedback was relatively intact in children with ADHD, but the late feedback processing was deviant (increased feedback LPP). This may explain the often observed positive effects of continuous reinforcement on performance and behaviour in children with ADHD. However, these group findings cannot be generalised to all individuals with the ADHD, because the feedback-related ERPs were associated with the severity of the inattention problems. Children with ADHD-combined type with more inattention problems showed both deviant early attentional selection of feedback stimuli, and deviant late processing of non-reward and punishment. PMID:23555639
Groen, Yvonne; Tucha, Oliver; Wijers, Albertus A; Althaus, Monika
2013-01-01
Current models of ADHD suggest abnormal reward and punishment sensitivity, but the exact mechanisms are unclear. This study aims to investigate effects of continuous reward and punishment on the processing of performance feedback in children with ADHD and the modulating effects of stimulant medication. 15 Methylphenidate (Mph)-treated and 15 Mph-free children of the ADHD-combined type and 17 control children performed a selective attention task with three feedback conditions: no-feedback, gain and loss. Event Related Potentials (ERPs) time-locked to feedback and errors were computed. All groups performed more accurately with gain and loss than without feedback. Feedback-related ERPs demonstrated no group differences in the feedback P2, but an enhanced late positive potential (LPP) to feedback stimuli (both gains and losses) for Mph-free children with ADHD compared to controls. Feedback-related ERPs in Mph-treated children with ADHD were similar to controls. Correlational analyses in the ADHD groups revealed that the severity of inattention problems correlated negatively with the feedback P2 amplitude and positively with the LPP to losses and omitted gains. The early selective attention for rewarding and punishing feedback was relatively intact in children with ADHD, but the late feedback processing was deviant (increased feedback LPP). This may explain the often observed positive effects of continuous reinforcement on performance and behaviour in children with ADHD. However, these group findings cannot be generalised to all individuals with the ADHD, because the feedback-related ERPs were associated with the severity of the inattention problems. Children with ADHD-combined type with more inattention problems showed both deviant early attentional selection of feedback stimuli, and deviant late processing of non-reward and punishment.
Thomson, Merran A; Yoder, Bradley A; Winter, Vicki T; Giavedoni, Luis; Chang, Ling Yi; Coalson, Jacqueline J
2006-11-01
Using the 125-day baboon model of bronchopulmonary dysplasia treated with prenatal steroid and exogenous surfactant, we hypothesized that a delay of extubation from low tidal volume positive pressure ventilation to nasal continuous positive airway pressure at 5 days (delayed nasal continuous positive airway pressure group) would not induce more lung injury when compared with baboons aggressively weaned to nasal continuous positive airway pressure at 24 hours (early nasal continuous positive airway pressure group), because both received positive pressure ventilation. After delivery by cesarean section at 125 days (term: 185 days), infants received 2 doses of Curosurf (Chiesi Farmaceutica S.p.A., Parma, Italy) and daily caffeine citrate. The delay in extubation to 5 days resulted in baboons in the delayed nasal continuous positive airway pressure group having a lower arterial to alveolar oxygen ratio, high PaCO2, and worse respiratory function. The animals in the delayed nasal continuous positive airway pressure group exhibited a poor respiratory drive that contributed to more reintubations and time on mechanical ventilation. A few animals in both groups developed necrotizing enterocolitis and/or sepsis, but infectious pneumonias were not documented. Cellular bronchiolitis and peribronchiolar alveolar wall thickening were more frequently seen in the delayed nasal continuous positive airway pressure group. Bronchoalveolar lavage levels of interleukin-6, interleukin-8, monocyte chemotactic protein-1, macrophage inflammatory protein-1 alpha, and growth-regulated oncogene-alpha were significantly increased in the delayed nasal continuous positive airway pressure group. Standard and digital morphometric analyses showed no significant differences in internal surface area and nodal measurements between the groups. Platelet endothelial cell adhesion molecule vascular staining was not significantly different between the 2 nasal continuous positive airway pressure groups. Volutrauma and/or low-grade colonization of airways secondary to increased reintubations and ventilation times are speculated to play causative roles in the delayed nasal continuous positive airway pressure group findings.
NASA Technical Reports Server (NTRS)
Ohara, Tetsuo
2012-01-01
A sub-aperture stitching optical interferometer can provide a cost-effective solution for an in situ metrology tool for large optics; however, the currently available technologies are not suitable for high-speed and real-time continuous scan. NanoWave s SPPE (Scanning Probe Position Encoder) has been proven to exhibit excellent stability and sub-nanometer precision with a large dynamic range. This same technology can transform many optical interferometers into real-time subnanometer precision tools with only minor modification. The proposed field-programmable gate array (FPGA) signal processing concept, coupled with a new-generation, high-speed, mega-pixel CMOS (complementary metal-oxide semiconductor) image sensor, enables high speed (>1 m/s) and real-time continuous surface profiling that is insensitive to variation of pixel sensitivity and/or optical transmission/reflection. This is especially useful for large optics surface profiling.
NASA Astrophysics Data System (ADS)
Kehrl, L. M.; Joughin, I. R.; Shean, D. E.
2016-12-01
Marine-terminating glaciers can be very sensitive to changes in ice-front position, depending on their geometry. If a nearly grounded glacier retreats into deeper water, the glacier typically must speed up to produce the additional longitudinal and lateral stress gradients necessary to restore force balance. This speedup often causes thinning, which can increase the glacier's susceptibility to further retreat. In this study, we combine satellite observations and numerical modeling (Elmer/Ice) to investigate how seasonal changes in ice-front position affect glacier speed and surface elevation at Helheim Glacier, SE Greenland, from 2010-2016. Helheim's calving front position fluctuated about a mean position from 2010-2016. During 2010/11, 2013/14, and 2015/16, Helheim seasonally retreated and advanced along a reverse bed slope by > 3 km. During these years, the glacier retreated from winter/spring to late summer and then readvanced until winter/spring. During the retreat, Helheim sped up by 20-30% and thinned by 20 m near its calving front. This thinning caused the calving front to unground, and a floating ice tongue was then able to readvance over the following winter with limited iceberg calving. The advance, which continued until the glacier reached the top of the bathymetric high, caused the glacier to slow and thicken. During years when Helheim likely did not form a floating ice tongue, iceberg calving continued throughout the winter. Consequently, the formation of this floating ice tongue may have helped stabilize Helheim after periods of rapid retreat and dynamic thinning. Helheim's rapid retreat from 2001-2005 also ended when a floating ice tongue formed and readvanced over the 2005/06 winter. These seasonal retreat/advance cycles may therefore be important for understanding Helheim's long-term behavior.
Martinek, Radek; Nedoma, Jan; Fajkus, Marcel; Kahankova, Radana; Konecny, Jaromir; Janku, Petr; Kepak, Stanislav; Bilik, Petr; Nazeran, Homer
2017-04-18
This paper focuses on the design, realization, and verification of a novel phonocardiographic- based fiber-optic sensor and adaptive signal processing system for noninvasive continuous fetal heart rate (fHR) monitoring. Our proposed system utilizes two Mach-Zehnder interferometeric sensors. Based on the analysis of real measurement data, we developed a simplified dynamic model for the generation and distribution of heart sounds throughout the human body. Building on this signal model, we then designed, implemented, and verified our adaptive signal processing system by implementing two stochastic gradient-based algorithms: the Least Mean Square Algorithm (LMS), and the Normalized Least Mean Square (NLMS) Algorithm. With this system we were able to extract the fHR information from high quality fetal phonocardiograms (fPCGs), filtered from abdominal maternal phonocardiograms (mPCGs) by performing fPCG signal peak detection. Common signal processing methods such as linear filtering, signal subtraction, and others could not be used for this purpose as fPCG and mPCG signals share overlapping frequency spectra. The performance of the adaptive system was evaluated by using both qualitative (gynecological studies) and quantitative measures such as: Signal-to-Noise Ratio-SNR, Root Mean Square Error-RMSE, Sensitivity-S+, and Positive Predictive Value-PPV.
A quantitative method for optimized placement of continuous air monitors.
Whicker, Jeffrey J; Rodgers, John C; Moxley, John S
2003-11-01
Alarming continuous air monitors (CAMs) are a critical component for worker protection in facilities that handle large amounts of hazardous materials. In nuclear facilities, continuous air monitors alarm when levels of airborne radioactive materials exceed alarm thresholds, thus prompting workers to exit the room to reduce inhalation exposures. To maintain a high level of worker protection, continuous air monitors are required to detect radioactive aerosol clouds quickly and with good sensitivity. This requires that there are sufficient numbers of continuous air monitors in a room and that they are well positioned. Yet there are no published methodologies to quantitatively determine the optimal number and placement of continuous air monitors in a room. The goal of this study was to develop and test an approach to quantitatively determine optimal number and placement of continuous air monitors in a room. The method we have developed uses tracer aerosol releases (to simulate accidental releases) and the measurement of the temporal and spatial aspects of the dispersion of the tracer aerosol through the room. The aerosol dispersion data is then analyzed to optimize continuous air monitor utilization based on simulated worker exposure. This method was tested in a room within a Department of Energy operated plutonium facility at the Savannah River Site in South Carolina, U.S. Results from this study show that the value of quantitative airflow and aerosol dispersion studies is significant and that worker protection can be significantly improved while balancing the costs associated with CAM programs.
I don't want to come back down: Undoing versus maintaining of reward recovery in older adolescents.
Gilbert, Kirsten E; Nolen-Hoeksema, Susan; Gruber, June
2016-03-01
Adolescence is characterized by heightened and sometimes impairing reward sensitivity, yet less is known about how adolescents recover from highly arousing positive states. This is particularly important given high onset rates of psychopathology associated with reward sensitivity during late adolescence and early adulthood. The current study thus utilized a novel reward sensitivity task in order to examine potential ways in which older adolescent females (ages 18-21; N = 83) might recover from high arousal positive reward sensitive states. Participants underwent a fixed incentive reward sensitivity task and subsequently watched a neutral, sad, or a low approach-motivated positive emotional film clip during which subjective and physiological recovery was assessed. Results indicated that the positive and negative film conditions were associated with maintained physiological arousal while the neutral condition facilitated faster physiological recovery from the reward sensitivity task. It is interesting to note that individual differences in self-reported positive emotion during the reward task were associated with faster recovery in the neutral condition. Findings suggest elicited emotion (regardless of valence) may serve to maintain reward sensitivity whereas self-reported positive emotional experience may be a key ingredient facilitating physiological recovery or undoing. Understanding the nuances of reward recovery provides a critical step in understanding the etiology and persistence of reward dysregulation more generally. (c) 2016 APA, all rights reserved).
Theoretical Noise Analysis on a Position-sensitive Metallic Magnetic Calorimeter
NASA Technical Reports Server (NTRS)
Smith, Stephen J.
2007-01-01
We report on the theoretical noise analysis for a position-sensitive Metallic Magnetic Calorimeter (MMC), consisting of MMC read-out at both ends of a large X-ray absorber. Such devices are under consideration as alternatives to other cryogenic technologies for future X-ray astronomy missions. We use a finite-element model (FEM) to numerically calculate the signal and noise response at the detector outputs and investigate the correlations between the noise measured at each MMC coupled by the absorber. We then calculate, using the optimal filter concept, the theoretical energy and position resolution across the detector and discuss the trade-offs involved in optimizing the detector design for energy resolution, position resolution and count rate. The results show, theoretically, the position-sensitive MMC concept offers impressive spectral and spatial resolving capabilities compared to pixel arrays and similar position-sensitive cryogenic technologies using Transition Edge Sensor (TES) read-out.
The sensitivity of the QuantiFERON®-TB Gold Plus assay in Zambian adults with active tuberculosis
Amofa-Sekyi, M.; Maluzi, K.; Kaluba-Milimo, D.; Cheeba-Lengwe, M.; Chiwele, K.; Kosloff, B.; Floyd, S.; Bailey, S-L.; Ayles, H.
2017-01-01
SUMMARY SETTING AND OBJECTIVE: To investigate the sensitivity of the new interferon-gamma release assay (IGRA), QuantiFERON®-TB Gold Plus (QFT-Plus), for active TB (used as a surrogate for latent tuberculous infection) in a Zambian TB clinic. DESIGN: Consecutive smear or Xpert® MTB/RIF-positive adult (age ⩾18 years) pulmonary TB patients were recruited between June 2015 and March 2016. Venous blood was tested using QFT-Plus. The sensitivity was defined as the number positive divided by the total number tested. Using logistic regression, factors associated with positive QFT-Plus results were explored. RESULTS: Of 108 patients (median age 32 years, interquartile range 27–38; 73% male; 63% human immunodeficiency virus [HIV] positive), 90 were QFT-Plus-positive, 11 were negative and seven had indeterminate results; sensitivity was 83% (95%CI 75–90). There was no difference in sensitivity by HIV status (HIV-positive 85%, 95%CI 75–93; n = 68 vs. HIV-negative 80%, 95%CI 64–91; n = 40; P = 0.59). In models adjusted for age alone, CD4 cell count <100 cells/μl (OR 0.15, 95%CI 0.02–0.96; P=0.05) and body mass index <18.5 kg/m2 (OR 0.27, 95%CI 0.08–0.91; P = 0.02) were associated with decreased odds of positive QFT-Plus results. CONCLUSION: Overall, the sensitivity of QFT-Plus is similar to that of the tuberculin skin test and other IGRAs. While overall sensitivity is not affected by HIV status, QFT-Plus sensitivity was lower among people living with HIV/acquired immune-deficiency syndrome with severe immunosuppression. PMID:28482964
The importance of clinical monitoring for compliance with Continuous Positive Airway Pressure.
Pelosi, Lucas B; Silveira, Mariana L C; Eckeli, Alan L; Chayamiti, Emilia M P C; Almeida, Leila A; Sander, Heidi H; Küpper, Daniel S; Valera, Fabiana C P
Obstructive sleep apnea syndrome is currently a public health problem of great importance. When misdiagnosed or improperly treated, it can lead to serious consequences on patients' quality of life. The gold standard treatment for cases of obstructive sleep apnea syndrome, especially in mild to severe and symptomatic cases, is continuous positive airway pressure therapy. Compliance with continuous positive airway pressure therapy is directly dependent on the active participation of the patient, which can be influenced by several factors. The objective of this study is to describe the factors related to compliance with continuous positive airway pressure therapy, and to analyze which associated factors directly influence the efficiency of the treatment. Patients who received continuous positive airway pressure therapy through the Municipal Health Department of the city of Ribeirão Preto were recruited. A structured questionnaire was administered to the patients. Compliance with continuous positive airway pressure therapy was assessed by average hours of continuous positive airway pressure therapy usage per night. Patients with good compliance (patients using continuous positive airway pressure therapy ≥4h/night) were compared to those with poor compliance (patients using <4h/night). 138 patients were analyzed: 77 (55.8%) were considered compliant while 61 (44.2%) were non-compliant. The comparison between the two groups showed that regular monitoring by a specialist considerably improved compliance with continuous positive airway pressure therapy (odds ratio, OR=2.62). Compliance with continuous positive airway pressure therapy is related to educational components, which can be enhanced with continuous and individualized care to patients with obstructive sleep apnea syndrome. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
On multi-sensitivity with respect to a vector
NASA Astrophysics Data System (ADS)
Jiao, Lixin; Wang, Lidong; Li, Fengquan; Liu, Heng
2018-05-01
Consider the surjective continuous map f: X → X defined on a compact metric space X. Let 𝒦(X) be the space of all non-empty compact subsets of X equipped with the Hausdorff metric and define f¯: 𝒦(X) →𝒦(X) by f¯(A) = {f(a),a ∈ A} for any A ∈𝒦(X). In this paper, we introduce several stronger versions of sensitivities, such as multi-sensitivity with respect to a vector, 𝒩-sensitivity, strong multi-sensitivity. We obtain some basic properties of the concepts of these sensitivities and discuss the relationships with other sensitivities for continuous self-map on [0,1]. Some sufficient conditions for a dynamical system to be 𝒩-sensitive are presented. Also, it is shown that the strong multi-sensitivity of f implies that f¯ is 𝒩-sensitive. In turn, the 𝒩-sensitivity of f¯ implies that f is 𝒩-sensitive. In particular, it is proved that if f is a multi-transitive map with dense periodic sets, then f is 𝒩-sensitive. Finally, we give a multi-sensitive example which is not 𝒩-sensitive.
Khoharo, Haji Khan
2011-07-01
Seventy-six blood culture positive typhoid cases and forty-eight controls were studied. The typhidot test was positive in 74 (97.36%) cases, with a sensitivity, specificity and positive predictive value of 96%, 89.5%, and 95%, respectively, compared to the Widal test which was positive in 56 (73.68%) cases with a sensitivity, specificity, and positive predictive value of 72%, 87%, and 87%, respectively (P = 0.001). In the control group, seven (14.5%) cases tested positive for the Widal test and two (4.16%) for the typhidot (P = 0.001), yielding the sensitivity and specificity for the Widal test and the typhidot test of 63% and 83%, and 85% and 97%, respectively. We conclude that the Dot-EIA (enzyme immunoassay; typhidot) is a more sensitive and specific test which is easy to perform and more reliable compared to the Widal test and that it is useful in early therapy.
Har-Shai, Y; Hai, N; Taran, A; Mayblum, S; Barak, A; Tzur, E; Schafer, I; David, R; David, E; Linn, S
2001-12-01
This article reports on the sensitivity and positive predictive value of clinical diagnosis of benign and malignant skin tumors by expert plastic surgeons in an Israeli clinic. Most published reports have focused on the sensitivity of clinicians' diagnoses, a general measure of the physician's skill that does not predict the rate of accuracy of a physician's diagnoses. Our study of 835 lesions in 778 patients, one of the largest Israeli series, assesses the clinical diagnosis of malignant and benign skin tumors and is one of the few that provide information on the positive predictive value, the measure that is of interest to both physicians and patients. The majority of tumors were benign (56.8 percent), 31.6 percent were malignant, and 11.6 percent were premalignant. Among the 474 benign lesions, 46 percent were nevi. The most common nevi subclass was compound nevi (53 percent), 9 percent of the nevi were dysplastic, and 5 percent were blue nevi. The most common malignant tumor was basal cell carcinoma, accounting for 78 percent of malignant tumors. Although sensitivity for clinical diagnosis of malignancy was 91.3 percent, the positive predictive value for clinical diagnosis of malignancy was 71.3 percent. The sensitivity rate for clinically diagnosing premalignant tumors was 42.3 percent, whereas the positive predictive value for these diagnoses was higher (64.1 percent). The sensitivity rate for diagnosis of all benign lesions was 85.9 percent, and the positive predictive value was 94.2 percent. The sensitivity rate for diagnosis of all nevi was 87.6 percent, and the positive predictive value was 85.7 percent: i.e., only seven of the 218 pathologically proven diagnoses of nevi (3.2 percent) were falsely diagnosed as malignant lesions. Even more interestingly, five of the 223 clinical diagnoses of nevi (2.2 percent) were pathologically proven to be malignant melanomas, and seven were found to be premalignant lesions (3.1 percent). It was concluded that publications which report only on the sensitivity neglect to provide information of interest regarding the positive predictive value. Often, positive predictive value is qualitatively different from the sensitivity, and thus relying only on the sensitivity may lead to incorrect evaluation of a clinical judgment, which may result in erroneous surgical decisions.
Saijo, Masayuki; Qing, Tang; Niikura, Masahiro; Maeda, Akihiko; Ikegami, Tetsuro; Sakai, Koji; Prehaud, Christophe; Kurane, Ichiro; Morikawa, Shigeru
2002-01-01
A HeLa cell line continuously expressing recombinant nucleoprotein (rNP) of the Crimean-Congo hemorrhagic fever virus (CCHFV) was established by transfection with an expression vector containing the cDNA of CCHFV NP (pKS336-CCHFV-NP). These cells were used as antigens for indirect immunofluorescence (IF) to detect immunoglobulin G antibodies to CCHFV. The sensitivity and specificity of this IF technique were examined by using serum samples and were compared to those of the IF technique using CCHFV-infected Vero E6 cells (authentic antigen). Staining of the CCHFV rNP expressed in HeLa cells showed a unique granular pattern similar to that of CCHFV-infected Vero E6 cells. Positive staining could easily be distinguished from a negative result. All 13 serum samples determined to be positive by using the authentic antigen were also determined to be positive by using CCHFV rNP-expressing HeLa cells (recombinant antigen). The 108 serum samples determined to be negative by using the authentic antigen were also determined to be negative by using the recombinant antigen. Thus, both the sensitivity and the specificity of this IF technique were 100% compared to the IF with authentic antigen. The novel IF technique using CCHFV rNP-expressing HeLa cells can be used not only for diagnosis of CCHF but also for epidemiological studies on CCHFV infections. PMID:11825944
Pan, Liping; Jia, Hongyan; Liu, Fei; Gao, Mengqiu; Sun, Huishan; Du, Boping; Sun, Qi; Xing, Aiying; Wei, Rongrong; Zhang, Zongde
2015-12-01
To evaluate the value of T-SPOT.TB assay in the diagnosis of pulmonary tuberculosis within different age groups. We analyzed 1 518 suspected pulmonary tuberculosis (PTB) patients who were admitted to the Beijing Chest Hospital from November 2012 to February 2014 and had valid T-SPOT.TB tests before anti-tuberculosis therapy. The 599 microbiologically and/or histopathologically-confirmed PTB patients (16-89 years old, 388 males and 211 females) and 235 non-TB patients (14-85 years old, 144 males and 91 females) were enrolled for the analysis of diagnostic performance of T-SPOT.TB, while patients with uncertain diagnosis or diagnosis based on clinical impression (n=684) were excluded from the analysis. The sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio of the T-SPOT.TB were analyzed according to the final diagnosis. Furthermore, the diagnostic performance of T-SPOT.TB assay in the younger patients (14-59 years old) and elderly patients (60-89 years old) were also analyzed respectively. Categorical variables were compared by Pearson's Chi-square test, while continuous variables were compared by the Mann-Whitney U-test. The sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio of the T-SPOT.TB in diagnosis of PTB were 90.1% (540/599), 65.5% (154/235), 86.9% (540/621), 72.3% (154/213), 2.61, and 0.15, respectively. The sensitivity and specificity of T-SPOT.TB assay were 92.6% (375/405) and 75.6% (99/131), respectively in the younger patients, and 85.0% (165/194), 52.9% (55/104) respectively in the elderly patients. The sensitivity and specificity of T-SPOT.TB assay in the younger patients were significantly higher than those in the elderly patients (P<0.01), and the spot forming cells in the younger PTB patients were significantly higher than in the elderly PTB patients [300 (126, 666)/10(6) PBMCs vs. 258 (79, 621)/10(6) PBMCs, P=0.037]. T-SPOT.TB is a promising test in the diagnosis of younger patients (14-59 years old) with suspected PTB, but the diagnostic performance in elderly patients (60-89 years old) is relatively reduced.
Continuous model for the rock-scissors-paper game between bacteriocin producing bacteria.
Neumann, Gunter; Schuster, Stefan
2007-06-01
In this work, important aspects of bacteriocin producing bacteria and their interplay are elucidated. Various attempts to model the resistant, producer and sensitive Escherichia coli strains in the so-called rock-scissors-paper (RSP) game had been made in the literature. The question arose whether there is a continuous model with a cyclic structure and admitting an oscillatory dynamics as observed in various experiments. The May-Leonard system admits a Hopf bifurcation, which is, however, degenerate and hence inadequate. The traditional differential equation model of the RSP-game cannot be applied either to the bacteriocin system because it involves positive interaction terms. In this paper, a plausible competitive Lotka-Volterra system model of the RSP game is presented and the dynamics generated by that model is analyzed. For the first time, a continuous, spatially homogeneous model that describes the competitive interaction between bacteriocin-producing, resistant and sensitive bacteria is established. The interaction terms have negative coefficients. In some experiments, for example, in mice cultures, migration seemed to be essential for the reinfection in the RSP cycle. Often statistical and spatial effects such as migration and mutation are regarded to be essential for periodicity. Our model gives rise to oscillatory dynamics in the RSP game without such effects. Here, a normal form description of the limit cycle and conditions for its stability are derived. The toxicity of the bacteriocin is used as a bifurcation parameter. Exact parameter ranges are obtained for which a stable (robust) limit cycle and a stable heteroclinic cycle exist in the three-species game. These parameters are in good accordance with the observed relations for the E. coli strains. The roles of growth rate and growth yield of the three strains are discussed. Numerical calculations show that the sensitive, which might be regarded as the weakest, can have the longest sojourn times.
Economic values under inappropriate normal distribution assumptions.
Sadeghi-Sefidmazgi, A; Nejati-Javaremi, A; Moradi-Shahrbabak, M; Miraei-Ashtiani, S R; Amer, P R
2012-08-01
The objectives of this study were to quantify the errors in economic values (EVs) for traits affected by cost or price thresholds when skewed or kurtotic distributions of varying degree are assumed to be normal and when data with a normal distribution is subject to censoring. EVs were estimated for a continuous trait with dichotomous economic implications because of a price premium or penalty arising from a threshold ranging between -4 and 4 standard deviations from the mean. In order to evaluate the impacts of skewness, positive and negative excess kurtosis, standard skew normal, Pearson and the raised cosine distributions were used, respectively. For the various evaluable levels of skewness and kurtosis, the results showed that EVs can be underestimated or overestimated by more than 100% when price determining thresholds fall within a range from the mean that might be expected in practice. Estimates of EVs were very sensitive to censoring or missing data. In contrast to practical genetic evaluation, economic evaluation is very sensitive to lack of normality and missing data. Although in some special situations, the presence of multiple thresholds may attenuate the combined effect of errors at each threshold point, in practical situations there is a tendency for a few key thresholds to dominate the EV, and there are many situations where errors could be compounded across multiple thresholds. In the development of breeding objectives for non-normal continuous traits influenced by value thresholds, it is necessary to select a transformation that will resolve problems of non-normality or consider alternative methods that are less sensitive to non-normality.
Lupin sensitization and clinical allergy in food allergic children in Norway.
Lindvik, Helene; Holden, Lise; Løvik, Martinus; Cvancarova, Milada; Halvorsen, Ragnhild
2008-01-01
The aim of the present pilot study was to investigate to what extent children in Norway sensitized to lupin had clinical lupin allergy, and to compare sensitization to lupin with sensitization to other legumes. Thirty-five children with food allergy referred to a national referral hospital were evaluated with skin prick test (SPT) and analysis of serum-specific IgE to lupin, peanut, pea and soy. The children with positive SPTs to lupin were offered oral food challenges with lupin flour. Fifteen children (43%) had positive SPT and 17 children (49%) had serum-specific IgE to lupin. Ten SPT-positive children underwent oral food challenges and one experienced an allergic reaction to lupin flour. This child was one of six challenged children with IgE antibodies to peanut >15 kU(A)/L. There was a strong relationship between positive SPT to lupin flour and positive SPT to soy and between positive SPT to lupin and specific IgE to soy, pea and peanut. Children with sensitization to lupin are not likely to have a clinical lupin allergy. Avoidance of lupin on the basis of lupin sensitization or peanut allergy would lead to unnecessarily strict diets. Food challenge is currently necessary to diagnose lupin allergy.
Polycystic ovary syndrome: a review for dermatologists: Part II. Treatment.
Buzney, Elizabeth; Sheu, Johanna; Buzney, Catherine; Reynolds, Rachel V
2014-11-01
Dermatologists are in a key position to treat the manifestations of polycystic ovary syndrome (PCOS). The management of PCOS should be tailored to each woman's specific goals, reproductive interests, and particular constellation of symptoms. Therefore, a multidisciplinary approach is recommended. In part II of this continuing medical education article, we present the available safety and efficacy data regarding treatments for women with acne, hirsutism, and androgenetic alopecia. Therapies discussed include lifestyle modification, topical therapies, combined oral contraceptives, antiandrogen agents, and insulin-sensitizing drugs. Treatment recommendations are made based on the current available evidence. Copyright © 2014 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.
Conical differentiability for evolution variational inequalities
NASA Astrophysics Data System (ADS)
Jarušek, Jiří; Krbec, Miroslav; Rao, Murali; Sokołowski, Jan
The conical differentiability of solutions to the parabolic variational inequality with respect to the right-hand side is proved in the paper. From one side the result is based on the Lipschitz continuity in H {1}/{2},1 (Q) of solutions to the variational inequality with respect to the right-hand side. On the other side, in view of the polyhedricity of the convex cone K={v∈ H;v |Σ c⩾0,v |Σ d=0}, we prove new results on sensitivity analysis of parabolic variational inequalities. Therefore, we have a positive answer to the question raised by Fulbert Mignot (J. Funct. Anal. 22 (1976) 25-32).
[An oral sensitization food allergy model in Brown-Norway rats].
Huang, Juan; Zhong, Yan; Cai, Wei; Zhang, Hongbo
2009-01-01
To develop an oral-sensitized animal model of food allergy using Brown-Norway (BN) rats and evaluate the sensitivity of ELISA and passive cutaneous anaphylaxis (PCA) in detecting ovalbumin-specific IgE antibody (OVA-IgE) level in sensitized animals. Sixteen 3-week old female BN rats were randomly divided into 3 groups: negative control group orally gavaged with saline, positive control group sensitized by intraperitoneal injection of 0. lmg/d OVA, and, study group sensitized by daily gavage of 1 mg/d ovalbumin (OVA). OVA-IgE was analyzed by ELISA and PCA method at week 4, 5, 6, 7, 8 and 9. At week 13, OVA-IgE level was analyzed after orally challenged by 1.0 ml of 100 mg/ml OVA. The ELISA result showed that the OVA-IgE level in study group was significantly increased at week 6, 7 and week 8 compared with negative control group (P < 0.05), and the highest level was found at week 6. There was no significant difference for the level of OVA-IgE between study group and positive control group. The sensitization rate in study group was 60%, 80% and 80% at week 6, 7 and 8 respectively, which was similar to positive control group. All PCA results in study group were negative, while in positive control group it was positive. Oral sensitization could be used as a suitable method to establish an animal model of food allergy, which is more comparable with the natural sensitization process in food allergy patients. ELISA method is more sensitive in detecting OVA-IgE level in oral sensitized animal model than PCA method.
Bayes to the Rescue: Continuous Positive Airway Pressure Has Less Mortality Than High-Flow Oxygen.
Modesto I Alapont, Vicent; Khemani, Robinder G; Medina, Alberto; Del Villar Guerra, Pablo; Molina Cambra, Alfred
2017-02-01
The merits of high-flow nasal cannula oxygen versus bubble continuous positive airway pressure are debated in children with pneumonia, with suggestions that randomized controlled trials are needed. In light of a previous randomized controlled trial showing a trend for lower mortality with bubble continuous positive airway pressure, we sought to determine the probability that a new randomized controlled trial would find high-flow nasal cannula oxygen superior to bubble continuous positive airway pressure through a "robust" Bayesian analysis. Sample data were extracted from the trial by Chisti et al, and requisite to "robust" Bayesian analysis, we specified three prior distributions to represent clinically meaningful assumptions. These priors (reference, pessimistic, and optimistic) were used to generate three scenarios to represent the range of possible hypotheses. 1) "Reference": we believe bubble continuous positive airway pressure and high-flow nasal cannula oxygen are equally effective with the same uninformative reference priors; 2) "Sceptic on high-flow nasal cannula oxygen": we believe that bubble continuous positive airway pressure is better than high-flow nasal cannula oxygen (bubble continuous positive airway pressure has an optimistic prior and high-flow nasal cannula oxygen has a pessimistic prior); and 3) "Enthusiastic on high-flow nasal cannula oxygen": we believe that high-flow nasal cannula oxygen is better than bubble continuous positive airway pressure (high-flow nasal cannula oxygen has an optimistic prior and bubble continuous positive airway pressure has a pessimistic prior). Finally, posterior empiric Bayesian distributions were obtained through 100,000 Markov Chain Monte Carlo simulations. In all three scenarios, there was a high probability for more death from high-flow nasal cannula oxygen compared with bubble continuous positive airway pressure (reference, 0.98; sceptic on high-flow nasal cannula oxygen, 0.982; enthusiastic on high-flow nasal cannula oxygen, 0.742). The posterior 95% credible interval on the difference in mortality identified a future randomized controlled trial would be extremely unlikely to find a mortality benefit for high-flow nasal cannula oxygen over bubble continuous positive airway pressure, regardless of the scenario. Interpreting these findings using the "range of practical equivalence" framework would recommend rejecting the hypothesis that high-flow nasal cannula oxygen is superior to bubble continuous positive airway pressure for these children. For children younger than 5 years with pneumonia, high-flow nasal cannula oxygen has higher mortality than bubble continuous positive airway pressure. A future randomized controlled trial in this population is unlikely to find high-flow nasal cannula oxygen superior to bubble continuous positive airway pressure.
Bladder cancer screening in aluminum smelter workers.
Taiwo, Oyebode A; Slade, Martin D; Cantley, Linda F; Tessier-Sherman, Baylah; Galusha, Deron; Kirsche, Sharon R; Donoghue, A Michael; Cullen, Mark R
2015-04-01
To present results of a bladder cancer screening program conducted in 18 aluminum smelters in the United States from January 2000 to December 2010. Data were collected on a cohort of workers with a history of working in coal tar pitch volatile exposed areas including urine analysis for conventional cytology and ImmunoCyt/uCyt+ assay. ImmunoCyt/uCyt+ and cytology in combination showed a sensitivity of 62.30%, a specificity of 92.60%, a negative predictive value of 99.90%, and a positive predictive value of 2.96%. Fourteen cases of bladder cancer were detected, and the standardized incidence ratio of bladder cancer was 1.18 (95% confidence interval, 0.65 to 1.99). Individuals who tested positive on either test who were later determined to be cancer free had undergone expensive and invasive tests. Evidence to support continued surveillance of this cohort has not been demonstrated.
Bladder Cancer Screening in Aluminum Smelter Workers
Taiwo, Oyebode A.; Slade, Martin D.; Cantley, Linda F.; Tessier-Sherman, Baylah; Galusha, Deron; Kirsche, Sharon R.; Donoghue, A. Michael
2015-01-01
Objective: To present results of a bladder cancer screening program conducted in 18 aluminum smelters in the United States from January 2000 to December 2010. Methods: Data were collected on a cohort of workers with a history of working in coal tar pitch volatile exposed areas including urine analysis for conventional cytology and ImmunoCyt/uCyt+ assay. Results: ImmunoCyt/uCyt+ and cytology in combination showed a sensitivity of 62.30%, a specificity of 92.60%, a negative predictive value of 99.90%, and a positive predictive value of 2.96%. Fourteen cases of bladder cancer were detected, and the standardized incidence ratio of bladder cancer was 1.18 (95% confidence interval, 0.65 to 1.99). Individuals who tested positive on either test who were later determined to be cancer free had undergone expensive and invasive tests. Conclusions: Evidence to support continued surveillance of this cohort has not been demonstrated. PMID:25525927
Bilodeau, Marcel; Roy, Joseph
1963-01-01
This paper describes the results obtained in 200 patients with bronchopulmonary suppurative diseases who received kanamycin aerosol therapy under intermittent positive pressure and in whom bacterial sensitivity study (antibiogram) was favourable. This method of treatment was well tolerated and was practically free of side effects. In most cases the improvement was rapid, was maintained and was often life-saving. The first series contained nine patients with pulmonary tuberculosis and a constant finding of sputum positive for Koch bacillus; four of these became negative after eight weeks of treatment. This suggested that kanamycin aerosol therapy had some effect on the Koch bacillus and that the study should be continued with a much larger group of patients with tuberculous suppurative pulmonary diseases to determine the efficacy of this antibiotic. ImagesFig. 1aFig. 1bFig. 2aFig. 2bFig. 3aFig. 3bFig. 4aFig. 4bFig. 5aFig. 5b PMID:14045345
Thermo-optical properties of Alexandrite laser crystal
NASA Astrophysics Data System (ADS)
Loiko, Pavel; Ghanbari, Shirin; Matrosov, Vladimir; Yumashev, Konstantin; Major, Arkady
2018-02-01
Alexandrite is a well-known material for broadly tunable and power-scalable near-IR lasers. We measured the thermal coefficients of the optical path (TCOP) and thermo-optic coefficients (TOCs) of Alexandrite at 632.8 nm for three principal light polarizations, E || a, E || b and E || c. All TOCs are positive and show a notable polarization-anisotropy, dna/dT = 5.5, dnb/dT = 7.0 and dnc/dT = 14.9×10-6 K-1. We also characterized thermal lensing in a continuous-wave Alexandrite laser which used a Brewster-oriented c-cut 0.16 at.% Cr3+ doped BeAl2O4 crystal pumped at 532 nm and emitted at 750.9 nm (E || b). The measured thermal lens was positive and astigmatic. The sensitivity factors of the thermal lens (Mx,y = dDx,y/dPabs) were found to be Mx = 1.74 and My = 2.38 [m-1/W].
Modular probes for enriching and detecting complex nucleic acid sequences
NASA Astrophysics Data System (ADS)
Wang, Juexiao Sherry; Yan, Yan Helen; Zhang, David Yu
2017-12-01
Complex DNA sequences are difficult to detect and profile, but are important contributors to human health and disease. Existing hybridization probes lack the capability to selectively bind and enrich hypervariable, long or repetitive sequences. Here, we present a generalized strategy for constructing modular hybridization probes (M-Probes) that overcomes these challenges. We demonstrate that M-Probes can tolerate sequence variations of up to 7 nt at prescribed positions while maintaining single nucleotide sensitivity at other positions. M-Probes are also shown to be capable of sequence-selectively binding a continuous DNA sequence of more than 500 nt. Furthermore, we show that M-Probes can detect genes with triplet repeats exceeding a programmed threshold. As a demonstration of this technology, we have developed a hybrid capture method to determine the exact triplet repeat expansion number in the Huntington's gene of genomic DNA using quantitative PCR.
Kim, Sang Hoon; Jeon, Eun Ju; Hong, Seok Min; Bae, Chang Hoon; Lee, Ho Yun; Park, Moo Kyun; Byun, Jae Yong; Kim, Myung Gu; Yeo, Seung Geun
2017-04-01
Changes over time in pathogens and their antibiotic sensitivity resulting from the recent overuse and misuse of antibiotics in otitis media (OM) have complicated treatment. This study evaluated changes over 5 years in principal pathogens and their antibiotic sensitivity in patients in Korea diagnosed with acute OM (AOM) and OM with effusion (OME). The study population consisted of 683 patients who visited the outpatient department of otorhinolaryngology in 7 tertiary hospitals in Korea between January 2010 and May 2015 and were diagnosed with acute AOM or OME. Aural discharge or middle ear fluid were collected from patients in the operating room or outpatient department and subjected to tests of bacterial identification and antibiotic sensitivity. The overall bacteria detection rate of AOM was 62.3% and OME was 40.9%. The most frequently isolated Gram-positive bacterial species was coagulase negative Staphylococcus aureus (CNS) followed by methicillin-susceptible S. aureus (MSSA), methicillin-resistant S. aureus (MRSA), and Streptococcus pneumonia (SP), whereas the most frequently isolated Gram-negative bacterium was Pseudomonas aeruginosa (PA). Regardless of OM subtype, ≥ 80% of CNS and MRSA strains were resistant to penicillin (PC) and tetracycline (TC); isolated MRSA strains showed low sensitivity to other antibiotics, with 100% resistant to PC, TC, cefoxitin (CFT), and erythromycin (EM); and isolated PA showed low sensitivity to quinolone antibiotics, including ciprofloxacin (CIP) and levofloxacin (LFX), and to aminoglycosides. Bacterial species and antibiotic sensitivity did not change significantly over 5 years. The rate of detection of MRSA was higher in OME than in previous studies. As bacterial predominance and antibiotic sensitivity could change over time, continuous and periodic surveillance is necessary in guiding appropriate antibacterial therapy. © 2017 The Korean Academy of Medical Sciences.
Wolday, D; Erge, W
1998-07-01
A retrospective analysis of all cases of Salmonella infections occurring between 1991 and 1995 was undertaken in order to evaluate the antimicrobial sensitivity pattern of the isolates from both human immunodeficiency virus (HIV) infected and uninfected Ethiopian patients. During the 5-year study period, we identified 147 cases of Salmonella infections. Only in 49 cases was the HIV serostatus known; 22 (44.9%) of the infections were in HIV seronegative patients while 27 (55.9%) were in HIV seropositive patients. The strains were isolated from blood (71.4%), urine (18.4%) and stool (8.2%). Salmonella infection was found to be more frequent (55.15% versus 44.9%) among HIV positive than HIV-negative patients. Moreover, Salmonella isolates recovered from HIV-seropositive patients were significantly resistant to many of the antibiotics tested when compared to the isolates from HIV-seronegative patients. The only chloramphenicol resistant Salmonella typhi occurred in a patient who was seropositive for HIV. According to these results, Ethiopian patients infected with HIV may be at risk of acquiring infections, especially non-typhoidal salmonellas, that are multi-drug resistant (MDR) strains than HIV-uninfected subjects. The emergence of MDR Salmonella infection among HIV-positive patients requires reassessment of chemotherapeutic approaches in this patient population, and warrants continued laboratory surveillance.
Interaction of Root Gravitropism and Phototropism in Arabidopsis Wild-Type and Starchless Mutants1
Vitha, Stanislav; Zhao, Liming; Sack, Fred David
2000-01-01
Root gravitropism in wild-type Arabidopsis and in two starchless mutants, pgm1-1 and adg1-1, was evaluated as a function of light position to determine the relative strengths of negative phototropism and of gravitropism and how much phototropism affects gravitropic measurements. Gravitropism was stronger than phototropism in some but not all light positions in wild-type roots grown for an extended period, indicating that the relationship between the two tropisms is more complex than previously reported. Root phototropism significantly influenced the time course of gravitropic curvature and the two measures of sensitivity. Light from above during horizontal exposure overestimated all three parameters for all three genotypes except the wild-type perception time. At the irradiance used (80 μmol m−2 s−1), the shortest periods of illumination found to exaggerate gravitropism were 45 min of continuous illumination and 2-min doses of intermittent illumination. By growing roots in circumlateral light or by gravistimulating in the dark, corrected values were obtained for each gravitropic parameter. Roots of both starchless mutants were determined to be about three times less sensitive than prior estimates. This study demonstrates the importance of accounting for phototropism in the design of root gravitropism experiments in Arabidopsis. PMID:10677438
Sensitivity and specificity of the World Health Organization pertussis clinical case definition.
Ghanaie, Roxana Mansour; Karimi, Abdollah; Sadeghi, Hossein; Esteghamti, Abdolreza; Falah, Fateme; Armin, Shahnaz; Fahimzad, Alireza; Shamshiri, Ahmadreza; Kahbazi, Manige; Shiva, Faride
2010-12-01
Bordetella pertussis continues to circulate even in countries with good childhood vaccination coverage. This study was undertaken to define the relationship between documented disease and the clinical criteria proposed by the World Health Organization (WHO). Nasopharyngeal swab samples were collected from previously healthy 6-14-year-old school children in Tehran, presenting with persistent cough of at least 2- week duration. Specimens were examined for Bordetella pertussis and Bordetella parapertussis by culture and polymerase chain reaction (PCR). Out of 6601 students, 328 (5.0%) had been coughing for at least 2 weeks. Of these children with cough, 182 (55.5%) experienced whooping, 194 (59.1%) suffered a paroxysmal cough, and 73 (22.3%) had post-tussive vomiting. Twenty-one (6.4%) samples tested positive for B. pertussis and six (1.8%) for B. parapertussis by PCR. Culture of four (1.2%) specimens was positive for B. pertussis. In comparison to PCR, the sensitivity and the specificity of the WHO clinical criteria (year 2000) were 95.2% and 15.0%, respectively. Pertussis remains one of the etiologies of prolonged cough, even in communities with high immunization in children. The specificity of the WHO criteria is low in diagnosing pertussis compared with PCR. Copyright © 2010 International Society for Infectious Diseases. All rights reserved.
NASA Technical Reports Server (NTRS)
Gentz, Steven J.; Pandipati, Radha; Ling, Jerri; Miller, Thomas; Jeevarajan, Judith; Halpert, Gerald; Zimmerman, Albert
2005-01-01
The purpose of the GSFC position paper is to identify critical HST milestone dates for continued science studies followed by the attachment of a re-entry module or a robotic servicing mission. The paper examines the viability of the HST with respect to the NiH2 continued battery charge capacity. In the course of the assessment, it was recognized that the HST battery thermal control system has an average heat dissipation limitation of 30 W per bay per orbit cycle. This thermal constraint will continue to govern options for battery capacity maintenance. In addition, the HST usage represents the longest exposure ofNiH2 batteries to Low Earth Orbit (LEO) at the current level of Depth of Discharge (DOD). Finally, the current battery life is at the limit predicted by the manufacturer, Eaglepicher. Therefore, given these factors, the potential exists that the HST battery capacities could radically degrade at any point. Given this caveat on any life extrapolations, the conservative model proposed in the GSFC position paper was viewed by the NESC as having several technical assumptions such as limited utilization of flight battery capacity data, the susceptibility of the proposed prediction method to large variations when supplemented with additional information, and the failure to qualitatively or quantitatively assess life prediction sensitivities. The NESC conducted an independent evaluation of the supporting information and assumptions to generate the predictions for battery capacity loss and practicality of on-orbit battery conditioning.
Burchinal, Margaret R.; Vandell, Deborah Lowe; Belsky, Jay
2016-01-01
Longitudinal data are used to examine whether effects of early child care are amplified and/or attenuated by later parenting. Analyses tested these interactions using parenting as both a categorical and continuous variable to balance power and flexibility in testing moderation. The most consistent finding was that maternal sensitivity during adolescence accentuated the association between child care quality and adolescent academic-cognitive skills at age 15 years when maternal sensitivity during adolescence was high. This interaction was obtained in analyses with maternal sensitivity as both a categorical and continuous variable. Relations between early child care hours and adolescent behavioral outcomes also were moderated by maternal sensitivity, with longer child care hours predicting more impulsivity and externalizing at age 15 when maternal sensitivity during middle childhood, scored as a categorical variable, was low to moderate and when maternal sensitivity during adolescence, scored as a continuous variable, was lower. These findings suggest that some child care effects are moderated by subsequent parenting and that this moderation may take both linear and nonlinear forms. PMID:23937381
The Usefulness of Rapid Diagnostic Tests in the New Context of Low Malaria Transmission in Zanzibar
Shakely, Delér; Msellem, Mwinyi I.; Morris, Ulrika; Omar, Rahila; Weiping, Xu; Petzold, Max; Greenhouse, Bryan; Baltzell, Kimberly A.; Ali, Abdullah S.; Björkman, Anders; Mårtensson, Andreas
2013-01-01
Background We assessed if histidine-rich-protein-2 (HRP2) based rapid diagnostic test (RDT) remains an efficient tool for Plasmodium falciparum case detection among fever patients in Zanzibar and if primary health care workers continue to adhere to RDT results in the new epidemiological context of low malaria transmission. Further, we evaluated the performance of RDT within the newly adopted integrated management of childhood illness (IMCI) algorithm in Zanzibar. Methods and Findings We enrolled 3890 patients aged ≥2 months with uncomplicated febrile illness in this health facility based observational study conducted in 12 primary health care facilities in Zanzibar, between May-July 2010. One patient had an inconclusive RDT result. Overall 121/3889 (3.1%) patients were RDT positive. The highest RDT positivity rate, 32/528 (6.1%), was found in children aged 5–14 years. RDT sensitivity and specificity against PCR was 76.5% (95% CI 69.0–83.9%) and 99.9% (95% CI 99.7–100%), and against blood smear microscopy 78.6% (95% CI 70.8–85.1%) and 99.7% (95% CI 99.6–99.9%), respectively. All RDT positive, but only 3/3768 RDT negative patients received anti-malarial treatment. Adherence to RDT results was thus 3887/3889 (99.9%). RDT performed well in the IMCI algorithm with equally high adherence among children <5 years as compared with other age groups. Conclusions The sensitivity of HRP-2 based RDT in the hands of health care workers compared with both PCR and microscopy for P. falciparum case detection was relatively low, whereas adherence to test results with anti-malarial treatment was excellent. Moreover, the results provide evidence that RDT can be reliably integrated in IMCI as a tool for improved childhood fever management. However, the relatively low RDT sensitivity highlights the need for improved quality control of RDT use in primary health care facilities, but also for more sensitive point-of-care malaria diagnostic tools in the new epidemiological context of low malaria transmission in Zanzibar. Trial registration ClinicalTrials.gov NCT01002066 PMID:24023791
2014-01-01
Background The UK Clinical Aptitude Test (UKCAT) was introduced to facilitate widening participation in medical and dental education in the UK by providing universities with a continuous variable to aid selection; one that might be less sensitive to the sociodemographic background of candidates compared to traditional measures of educational attainment. Initial research suggested that males, candidates from more advantaged socioeconomic backgrounds and those who attended independent or grammar schools performed better on the test. The introduction of the A* grade at A level permits more detailed analysis of the relationship between UKCAT scores, secondary educational attainment and sociodemographic variables. Thus, our aim was to further assess whether the UKCAT is likely to add incremental value over A level (predicted or actual) attainment in the selection process. Methods Data relating to UKCAT and A level performance from 8,180 candidates applying to medicine in 2009 who had complete information relating to six key sociodemographic variables were analysed. A series of regression analyses were conducted in order to evaluate the ability of sociodemographic status to predict performance on two outcome measures: A level ‘best of three’ tariff score; and the UKCAT scores. Results In this sample A level attainment was independently and positively predicted by four sociodemographic variables (independent/grammar schooling, White ethnicity, age and professional social class background). These variables also independently and positively predicted UKCAT scores. There was a suggestion that UKCAT scores were less sensitive to educational background compared to A level attainment. In contrast to A level attainment, UKCAT score was independently and positively predicted by having English as a first language and male sex. Conclusions Our findings are consistent with a previous report; most of the sociodemographic factors that predict A level attainment also predict UKCAT performance. However, compared to A levels, males and those speaking English as a first language perform better on UKCAT. Our findings suggest that UKCAT scores may be more influenced by sex and less sensitive to school type compared to A levels. These factors must be considered by institutions utilising the UKCAT as a component of the medical and dental school selection process. PMID:24400861
In vivo sensitivity estimation and imaging acceleration with rotating RF coil arrays at 7 Tesla.
Li, Mingyan; Jin, Jin; Zuo, Zhentao; Liu, Feng; Trakic, Adnan; Weber, Ewald; Zhuo, Yan; Xue, Rong; Crozier, Stuart
2015-03-01
Using a new rotating SENSitivity Encoding (rotating-SENSE) algorithm, we have successfully demonstrated that the rotating radiofrequency coil array (RRFCA) was capable of achieving a significant reduction in scan time and a uniform image reconstruction for a homogeneous phantom at 7 Tesla. However, at 7 Tesla the in vivo sensitivity profiles (B1(-)) become distinct at various angular positions. Therefore, sensitivity maps at other angular positions cannot be obtained by numerically rotating the acquired ones. In this work, a novel sensitivity estimation method for the RRFCA was developed and validated with human brain imaging. This method employed a library database and registration techniques to estimate coil sensitivity at an arbitrary angular position. The estimated sensitivity maps were then compared to the acquired sensitivity maps. The results indicate that the proposed method is capable of accurately estimating both magnitude and phase of sensitivity at an arbitrary angular position, which enables us to employ the rotating-SENSE algorithm to accelerate acquisition and reconstruct image. Compared to a stationary coil array with the same number of coil elements, the RRFCA was able to reconstruct images with better quality at a high reduction factor. It is hoped that the proposed rotation-dependent sensitivity estimation algorithm and the acceleration ability of the RRFCA will be particularly useful for ultra high field MRI. Copyright © 2014 Elsevier Inc. All rights reserved.
In vivo sensitivity estimation and imaging acceleration with rotating RF coil arrays at 7 Tesla
NASA Astrophysics Data System (ADS)
Li, Mingyan; Jin, Jin; Zuo, Zhentao; Liu, Feng; Trakic, Adnan; Weber, Ewald; Zhuo, Yan; Xue, Rong; Crozier, Stuart
2015-03-01
Using a new rotating SENSitivity Encoding (rotating-SENSE) algorithm, we have successfully demonstrated that the rotating radiofrequency coil array (RRFCA) was capable of achieving a significant reduction in scan time and a uniform image reconstruction for a homogeneous phantom at 7 Tesla. However, at 7 Tesla the in vivo sensitivity profiles (B1-) become distinct at various angular positions. Therefore, sensitivity maps at other angular positions cannot be obtained by numerically rotating the acquired ones. In this work, a novel sensitivity estimation method for the RRFCA was developed and validated with human brain imaging. This method employed a library database and registration techniques to estimate coil sensitivity at an arbitrary angular position. The estimated sensitivity maps were then compared to the acquired sensitivity maps. The results indicate that the proposed method is capable of accurately estimating both magnitude and phase of sensitivity at an arbitrary angular position, which enables us to employ the rotating-SENSE algorithm to accelerate acquisition and reconstruct image. Compared to a stationary coil array with the same number of coil elements, the RRFCA was able to reconstruct images with better quality at a high reduction factor. It is hoped that the proposed rotation-dependent sensitivity estimation algorithm and the acceleration ability of the RRFCA will be particularly useful for ultra high field MRI.
Hybrid organic/inorganic position-sensitive detectors based on PEDOT:PSS/n-Si
NASA Astrophysics Data System (ADS)
Javadi, Mohammad; Gholami, Mahdiyeh; Torbatiyan, Hadis; Abdi, Yaser
2018-03-01
Various configurations like p-n junctions, metal-semiconductor Schottky barriers, and metal-oxide-semiconductor structures have been widely used in position-sensitive detectors. In this report, we propose a PEDOT:PSS/n-Si heterojunction as a hybrid organic/inorganic configuration for position-sensitive detectors. The influence of the thickness of the PEDOT:PSS layer, the wavelength of incident light, and the intensity of illumination on the device performance are investigated. The hybrid PSD exhibits very high sensitivity (>100 mV/mm), excellent nonlinearity (<3%), and a response correlation coefficient (>0.995) with a response time of <4 ms to the inhomogeneous IR illumination. The presented hybrid configuration also benefits from a straightforward low-temperature fabrication process. These advantages of the PEDOT:PSS/n-Si heterojunction are very promising for developing a new class of position-sensitive detectors based on the hybrid organic/inorganic junctions.
Nasrallah, Maha; Carmel, David; Lavie, Nilli
2009-01-01
Enhanced sensitivity to information of negative (compared to positive) valence has an adaptive value, for example, by expediting the correct choice of avoidance behavior. However, previous evidence for such enhanced sensitivity has been inconclusive. Here we report a clear advantage for negative over positive words in categorizing them as emotional. In 3 experiments, participants classified briefly presented (33 ms or 22 ms) masked words as emotional or neutral. Categorization accuracy and valence-detection sensitivity were both higher for negative than for positive words. The results were not due to differences between emotion categories in either lexical frequency, extremeness of valence ratings, or arousal. These results conclusively establish enhanced sensitivity for negative over positive words, supporting the hypothesis that negative stimuli enjoy preferential access to perceptual processing. PMID:19803583
Increasing Sensitivity In Continuous-Flow Electrophoresis
NASA Technical Reports Server (NTRS)
Sharnez, Rizwan; Sammons, David W.
1994-01-01
Sensitivity of continuous-flow electrophoresis (CFE) chamber increased by introducing lateral gradients in concentration of buffer solution and thickness of chamber. Such gradients, with resulting enhanced separation, achieved in CFE chamber with wedge-shaped cross section and collateral flow. Enables improved separations of homogeneous components of mixtures of variety of biologically important substances.
Barnes, R M; Duguid, J K; Roberts, F M; Risk, J M; Johnson, P M; Finn, R; Hardy, J; Napier, J A; Clarke, C A
1987-01-01
The effects of prior oral administration of erythrocyte membrane preparations (Oral Rh antigen) on the serum anti-Rh(D) antibody response has been evaluated in non-sensitized Rh(D)-negative male volunteers, and in female volunteers sensitized previously by Rh(D)-positive fetal blood during pregnancy. Sixty-one percent (11/18) of males who received oral Rh antigen (either D-positive or D-negative) before intravenous challenge with Rh(D)-positive cells produced detectable antibodies; of these 11, six received oral Rh(D)-negative antigen and five received oral Rh(D)-positive antigen. Seventy-two percent (13/18) of control males, who had received no prior oral Rh antigen, produced antibodies following challenge with Rh(D)-positive cells. Three out of six pre-sensitized females who received oral D-positive or D-negative Rh antigen for 4 weeks, but without intravenous challenge, increased their anti-Rh(D) antibody levels which peaked after 11-18 weeks: two had received Rh(D)-positive antigen, and one Rh(D)-negative antigen. These data indicate that administration of oral Rh antigen before parenteral immunization does not significantly suppress the anti-Rh(D) antibody response. Indeed, oral administration of either Rh(D)-positive or Rh(D)-negative antigen can boost systemic antibody in pre-sensitized females. These results do not support the rationale of treating Rh-sensitized pregnant women with oral Rh antigen. PMID:3113783
Simultaneous sensitivity to fragrances.
Buckley, D A; Basketter, D A; Smith Pease, C K; Rycroft, R J G; White, I R; McFadden, J P
2006-05-01
Cinnamal/cinnamic alcohol and isoeugenol/eugenol are pairs of related fragrance chemicals found in Fragrance Mix I (FM I), and thus are routinely tested in combination with other fragrances in the European standard patch test series. Their close structural similarity makes the occurrence of simultaneous sensitivity within these chemical pairs likely, although at present there are no robust data to support this hypothesis. To establish the frequency of simultaneous reactions to these fragrance chemicals in patients with suspected fragrance allergy attending a contact dermatitis clinic; to provide evidence in support of proposed metabolic pathways; and to determine whether including all four separately in FM I is necessary to avoid missing a diagnosis of fragrance allergy. We analysed retrospectively the records of patients patch tested to the European standard series during the 15-year period 1984-98 for positive reactions to FM I. In a subset of patients tested to the constituents of FM I, positive reactions to cinnamal, cinnamic alcohol, isoeugenol and eugenol were sought. Data were analysed using 2x2 contingency tables (Fisher's exact test). During this period, 23,660 patients were tested to the European standard series, of whom 1811 (7.7%) had positive reactions to FM I. Of the 1112 patients tested to the constituents of FM I, 934 had positive reactions to at least one constituent (total 1324 positive reactions to constituents). Of these 934, 826 also had positive reactions to FM I itself; 108 were negative to FM I but reacted to one or more of its constituents. One hundred and seventy-eight patients did not react to any of the breakdown constituents of FM I; 34 of these had positive reactions to FM I itself. Of 139 patients allergic to cinnamic alcohol, 87 were also allergic to cinnamal (63%), compared with 108 (11.1%) of 973 cinnamic alcohol-negative patients (P<0.00001). Of 231 patients allergic to isoeugenol, 50 were also allergic to eugenol (22%), vs. 109 (12.4%) of 881 isoeugenol-negative patients (P=0.0002). These data support in vitro experiments indicating that cinnamal and cinnamic alcohol may generate a common hapten and are consistent with the view that simultaneous sensitization to isoeugenol and eugenol occurs to a limited extent, despite their being metabolized via different pathways. In view of the substantial number of isolated reactions to each of these fragrance chemicals, all four should continue to be included separately as constituents of FM I.
Modeling and Implementation of Multi-Position Non-Continuous Rotation Gyroscope North Finder.
Luo, Jun; Wang, Zhiqian; Shen, Chengwu; Kuijper, Arjan; Wen, Zhuoman; Liu, Shaojin
2016-09-20
Even when the Global Positioning System (GPS) signal is blocked, a rate gyroscope (gyro) north finder is capable of providing the required azimuth reference information to a certain extent. In order to measure the azimuth between the observer and the north direction very accurately, we propose a multi-position non-continuous rotation gyro north finding scheme. Our new generalized mathematical model analyzes the elements that affect the azimuth measurement precision and can thus provide high precision azimuth reference information. Based on the gyro's principle of detecting a projection of the earth rotation rate on its sensitive axis and the proposed north finding scheme, we are able to deduct an accurate mathematical model of the gyro outputs against azimuth with the gyro and shaft misalignments. Combining the gyro outputs model and the theory of propagation of uncertainty, some approaches to optimize north finding are provided, including reducing the gyro bias error, constraining the gyro random error, increasing the number of rotation points, improving rotation angle measurement precision, decreasing the gyro and the shaft misalignment angles. According them, a north finder setup is built and the azimuth uncertainty of 18" is obtained. This paper provides systematic theory for analyzing the details of the gyro north finder scheme from simulation to implementation. The proposed theory can guide both applied researchers in academia and advanced practitioners in industry for designing high precision robust north finder based on different types of rate gyroscopes.
Evaluation of a Chlamydia trachomatis-specific, commercial, real-time PCR for use with ocular swabs.
Pickering, Harry; Holland, Martin J; Last, Anna R; Burton, Matthew J; Burr, Sarah E
2018-02-20
Trachoma, the leading infectious cause of blindness worldwide, is caused by conjunctival Chlamydia trachomatis infection. Trachoma is diagnosed clinically by observation of conjunctival inflammation and/or scarring; however, there is evidence that monitoring C. trachomatis infection may be required for elimination programmes. There are many commercial and 'in-house' nucleic acid amplification tests for the detection of C. trachomatis DNA, but the majority have not been validated for use with ocular swabs. This study evaluated a commercial assay, the Fast-Track Vaginal swab kit, using conjunctival samples from trachoma-endemic areas. An objective, biostatistical-based method for binary classification of continuous PCR data was developed, to limit potential user-bias in diagnostic settings. The Fast-Track Vaginal swab assay was run on 210 ocular swab samples from Guinea-Bissau and Tanzania. Fit of individual amplification curves to exponential or sigmoid models, derivative and second derivative of the curves and final fluorescence value were examined for utility in thresholding for determining positivity. The results from the Fast-Track Vaginal swab assay were evaluated against a commercial test (Amplicor CT/NG) and a non-commercial test (in-house droplet digital PCR), both of whose performance has previously been evaluated. Significant evidence of exponential amplification (R 2 > 0.99) and final fluorescence > 0.15 were combined for thresholding. This objective approach identified a population of positive samples, however there were a subset of samples that amplified towards the end of the cycling protocol (at or later than 35 cycles), which were less clearly defined. The Fast-Track Vaginal swab assay showed good sensitivity against the commercial (95.71) and non-commercial (97.18) tests. Specificity was lower against both (90.00 and 96.55, respectively). This study defined a simple, automated protocol for binary classification of continuous, real-time qPCR data, for use in an end-point diagnostic test. This method identified a population of positive samples, however, as with manual thresholding, a subset of samples that amplified towards the end of the cycling program were less easily classified. When used with ocular swabs, the Fast-Track Vaginal swab assay had good sensitivity for C. trachomatis detection, but lower specificity than the commercial and non-commercial assays it was evaluated against, possibly leading to false positives.
Vantage sensitivity: individual differences in response to positive experiences.
Pluess, Michael; Belsky, Jay
2013-07-01
The notion that some people are more vulnerable to adversity as a function of inherent risk characteristics is widely embraced in most fields of psychology. This is reflected in the popularity of the diathesis-stress framework, which has received a vast amount of empirical support over the years. Much less effort has been directed toward the investigation of endogenous factors associated with variability in response to positive influences. One reason for the failure to investigate individual differences in response to positive experiences as a function of endogenous factors may be the absence of adequate theoretical frameworks. According to the differential-susceptibility hypothesis, individuals generally vary in their developmental plasticity regardless of whether they are exposed to negative or positive influences--a notion derived from evolutionary reasoning. On the basis of this now well-supported proposition, we advance herein the new concept of vantage sensitivity, reflecting variation in response to exclusively positive experiences as a function of individual endogenous characteristics. After distinguishing vantage sensitivity from theoretically related concepts of differential-susceptibility and resilience, we review some recent empirical evidence for vantage sensitivity featuring behavioral, physiological, and genetic factors as moderators of a wide range of positive experiences ranging from family environment and psychotherapy to educational intervention. Thereafter, we discuss genetic and environmental factors contributing to individual differences in vantage sensitivity, potential mechanisms underlying vantage sensitivity, and practical implications. 2013 APA, all rights reserved
The oblique effect is both allocentric and egocentric
Mikellidou, Kyriaki; Cicchini, Guido Marco; Thompson, Peter G.; Burr, David C.
2016-01-01
Despite continuous movements of the head, humans maintain a stable representation of the visual world, which seems to remain always upright. The mechanisms behind this stability are largely unknown. To gain some insight on how head tilt affects visual perception, we investigate whether a well-known orientation-dependent visual phenomenon, the oblique effect—superior performance for stimuli at cardinal orientations (0° and 90°) compared with oblique orientations (45°)—is anchored in egocentric or allocentric coordinates. To this aim, we measured orientation discrimination thresholds at various orientations for different head positions both in body upright and in supine positions. We report that, in the body upright position, the oblique effect remains anchored in allocentric coordinates irrespective of head position. When lying supine, gravitational effects in the plane orthogonal to gravity are discounted. Under these conditions, the oblique effect was less marked than when upright, and anchored in egocentric coordinates. The results are well explained by a simple “compulsory fusion” model in which the head-based and the gravity-based signals are combined with different weightings (30% and 70%, respectively), even when this leads to reduced sensitivity in orientation discrimination. PMID:26129862
Jiang, Minghuan; You, Joyce H S
2017-10-01
Continuation of dual antiplatelet therapy (DAPT) beyond 1 year reduces late stent thrombosis and ischemic events after drug-eluting stents (DES) but increases risk of bleeding. We hypothesized that extending DAPT from 12 months to 30 months in patients with acute coronary syndrome (ACS) after DES is cost-effective. A lifelong decision-analytic model was designed to simulate 2 antiplatelet strategies in event-free ACS patients who had completed 12-month DAPT after DES: aspirin monotherapy (75-162 mg daily) and continuation of DAPT (clopidogrel 75 mg daily plus aspirin 75-162 mg daily) for 18 months. Clinical event rates, direct medical costs, and quality-adjusted life-years (QALYs) gained were the primary outcomes from the US healthcare provider perspective. Base-case results showed DAPT continuation gained higher QALYs (8.1769 vs 8.1582 QALYs) at lower cost (USD42 982 vs USD44 063). One-way sensitivity analysis found that base-case QALYs were sensitive to odds ratio (OR) of cardiovascular death with DAPT continuation and base-case cost was sensitive to OR of nonfatal stroke with DAPT continuation. DAPT continuation remained cost-effective when the ORs of nonfatal stroke and cardiovascular death were below 1.241 and 1.188, respectively. In probabilistic sensitivity analysis, DAPT continuation was the preferred strategy in 74.75% of 10 000 Monte Carlo simulations at willingness-to-pay threshold of 50 000 USD/QALYs. Continuation of DAPT appears to be cost-effective in ACS patients who were event-free for 12-month DAPT after DES. The cost-effectiveness of DAPT for 30 months was highly subject to the OR of nonfatal stroke and OR of death with DAPT continuation. © 2017 Wiley Periodicals, Inc.
Refugee health and medical student training.
Griswold, Kim S
2003-10-01
Cultural awareness training is an increasingly important priority within medical curricula. This article describes an academic family practice-community partnership focusing on health care needs of refugees that became the model for a medical school selective on cultural sensitivity training. The monthly Refugee Health Night program featured dinner with preceptors and patients, international sessions on special medical needs of refugees, and actual clinical encounters with patients. Students were not expected to become culturally competent experts but, rather, health care providers sensitive to and appreciative of cultural context, experience, and expectations. We worked with students to develop sensitive methods of inquiry about mental health, especially around issues of war and torture. We used problem-based cases to emphasize primary care continuity and the benefit of establishing trust over time. Over 2 years, 50 students and nearly 300 refugees (more than 73 families) participated. Students reported that their interactions with the refugees provided positive learning experiences, including expanded knowledge of diverse cultures and enhanced skills for overcoming communication barriers. Patients of refugee status were able to have emergent health care needs met in a timely fashion. Providing health care for refugee individuals and families presents many challenges as well as extraordinary opportunities for patients and practitioners to learn from one another.
Identification of the need for home visiting nurse: development of a new assessment tool.
Taguchi, Atsuko; Nagata, Satoko; Naruse, Takashi; Kuwahara, Yuki; Yamaguchi, Takuhiro; Murashima, Sachiyo
2014-01-01
To develop a Home Visiting Nursing Service Need Assessment Form (HVNS-NAF) to standardize the decision about the need for home visiting nursing service. The sample consisted of older adults who had received coordinated services by care managers. We defined the need for home visiting nursing service by elderly individuals as the decision of the need by a care manager so that the elderly can continue to live independently. Explanatory variables included demographic factors, medical procedure, severity of illness, and caregiver variables. Multiple logistic regression was carried out after univariate analyses to decide the variables to include and the weight of each variable in the HVNS-NAF. We then calculated the sensitivity and specificity of each cutoff value, and defined the score with the highest sensitivity and specificity as the cutoff value. Nineteen items were included in the final HVNS-NAF. When the cutoff value was 2 points, the sensitivity was 77.0%, specificity 68.5%, and positive predictive value 56.8%. HVNS-NAF is the first validated standard based on characteristics of elderly clients who required home visiting nursing service. Using the HVNS-NAF may result in reducing the unmet need for home visiting nursing service and preventing hospitalization.
Liu, Jian; Huang, Xun; Liu, Yao; Xu, Hui; Gong, Rui'e; Li, Chunhui
2016-12-28
To analyze the clinical characteristics of continuous ambulatory peritoneal dialysis (CAPD) associated peritonitis in the tertiary hospitals and to discuss the preventive and therapeutic strategy. Methods: The clinical characteristics, pathogens, resistance and outcomes of 126 CAPD associated peritonitis in 104 patients from Jan, 2013 to June, 2016, were retrospectively analyzed. Results: Among the patients, the incidence rates of abdominal pain, fever, diarrhea and emesis were 104 (82.54%), 56 (44.44%), 49 (38.89%), and 31 (23.60%), respectively. Among them, 88 patients suffered peritonitis once, other 16 patients suffered multiple peritonitis or recurrent peritonitis for 38 times. Among the 38 times, the numbers for recurrent, repeated or catheter-associated peritonitis were 2, 2, or 3, respectively. Peritoneal fluids from 103 cases were cultured, and 64 cases were positive in bacteria, with a rate of 62.14%. A total of 70 strains of bacteria were separated, including 42 strains of gram-positive bacteria, 21 strains of gram-negative bacteria, and 7 strains of fungus. The most common gram-positive pathogens were Staphylococcus epidermidis, Enterococcus faecalis and Staphylococcus haemolyticus, while Escherichia coli, Klebsiella pneumoniae and Klebsiella pneumoniae were the most common gram-negative bacteria. Candida albicans was the major fungal pathogens. Gram-positive cocci showed resistance to gentamycin, levofloxacin, moxifloxacin, vancomycin and linezolid, with a rate at 20.00%, 36.11%, 5%, 0%, and 0%, respectively. The gram-negative bacilli were resistent to cefoperazone/sulbactam, gentamycin, cephazolin, and ceftazidime, with a rate at 6.25%, 10.53%, 64.29%, and 15.38%, respectively. There were no imipenem, amikacin, piperacillin/tazobactam-resistant strains were found. Conclusion: The most common pathogen causing CAPD associated peritonitis is gram-positive bacteria. It is crucial to take the anti-infection therapy for CAPD associated peritonitis early. The positive rates for bacterial culture need to be enhanced through improvement of methods. At the same time, doctors could improve the outcome of CAPD associated peritonitis by adjusting the medication according to the drug sensitivity results.
Dey, Asit; Mann, Danny D
2010-07-01
The objectives of the present study were: a) to investigate three continuous variants of the NASA-Task Load Index (TLX) (standard NASA (CNASA), average NASA (C1NASA) and principal component NASA (PCNASA)) and five different variants of the simplified subjective workload assessment technique (SSWAT) (continuous standard SSWAT (CSSWAT), continuous average SSWAT (C1SSWAT), continuous principal component SSWAT (PCSSWAT), discrete event-based SSWAT (D1SSWAT) and discrete standard SSWAT (DSSWAT)) in terms of their sensitivity and diagnosticity to assess the mental workload associated with agricultural spraying; b) to compare and select the best variants of NASA-TLX and SSWAT for future mental workload research in the agricultural domain. A total of 16 male university students (mean 30.4 +/- 12.5 years) participated in this study. All the participants were trained to drive an agricultural spraying simulator. Sensitivity was assessed by the ability of the scales to report the maximum change in workload ratings due to the change in illumination and difficulty levels. In addition, the factor loading method was used to quantify sensitivity. The diagnosticity was assessed by the ability of the scale to diagnose the change in task levels from single to dual. Among all the variants of NASA-TLX and SSWAT, PCNASA and discrete variants of SSWAT showed the highest sensitivity and diagnosticity. Moreover, among all the variants of NASA and SSWAT, the discrete variants of SSWAT showed the highest sensitivity and diagnosticity but also high between-subject variability. The continuous variants of both scales had relatively low sensitivity and diagnosticity and also low between-subject variability. Hence, when selecting a scale for future mental workload research in the agricultural domain, a researcher should decide what to compromise: 1) between-subject variability or 2) sensitivity and diagnosticity. STATEMENT OF RELEVANCE: The use of subjective workload scales is very popular in mental workload research. The present study investigated the different variants of two popular workload rating scales (i.e. NASA-TLX and SSWAT) in terms of their sensitivity and diagnositicity and selected the best variants of each scale for future mental workload research.
Grinsvall, Cecilia; Törnblom, Hans; Tack, Jan; Van Oudenhove, Lukas; Simrén, Magnus
2018-01-01
Background and objective Psychological states may interfere with visceral sensitivity. Here we investigate associations between psychosocial factors and visceral sensitivity in irritable bowel syndrome (IBS). Methods Two IBS patient cohorts (Cohort 1: n = 231, Rome II; Cohort 2: n = 141, Rome III) underwent rectal barostat testing, and completed questionnaires for anxiety, depression, somatization, and abuse. The associations between questionnaire measures and visceral sensitivity parameters were analyzed in three-step general linear models (step1: demographic and abuse variables; step 2: anxiety and depression; step 3: somatization). Results Cohort 1. Pain threshold was positively associated with age and female gender, and negatively with adult sexual abuse and somatization. Pain referral area was negatively associated with age and positively with somatization and GI-specific anxiety, the latter effect mediated by somatization. Cohort 2. Pain threshold was positively associated with age and male gender, and negatively with adult sexual abuse. Pain intensity ratings were positively associated with somatization, female gender and depression, the latter effect mediated by somatization. Conclusion Somatization is associated with most visceral sensitivity parameters, and mediates the effect of some psychological factors on visceral sensitivity. It may reflect a psychobiological sensitization process driving symptom generation in IBS. In addition, abuse history was found to independently affect some visceral sensitivity parameters. PMID:29511560
Basketter, D A; Selbie, E; Scholes, E W; Lees, D; Kimber, I; Botham, P A
1993-01-01
The guinea pig maximization test and the Buehler occluded patch test are used widely to identify the sensitization potential of new chemicals. This information enables toxicologists and/or regulatory authorities to determine whether a chemical should be classified formally as a skin sensitizer. Both to improve and to harmonize these assessments internationally, the OECD has recommended recently that moderate rather than strong contact sensitizers are used as positive control substances. The purpose is to ensure an adequate level of sensitivity in sensitization assays performed at specific testing establishments. Results from two laboratories reported here show that the minimum acceptable standard laid down by the OECD can be achieved and indeed commonly exceeded by a substantial margin. Furthermore, results with these positive controls in a new method, the local lymph node assay, also appear to satisfy similar criteria, suggesting results from this assay, including negative data, should be acceptable for classification purposes. However, a review of the way in which results with new chemicals will be interpreted for regulatory purposes, in the context of positive control data, reveals that considerable inadequacies still exist. It is recommended that ultimately, sensitization data can only be interpreted meaningfully (i.e. to protect humans from sensitization hazards) by considering the potency of the contact allergen in the context of the sensitivity of the assay performed at the particular testing institution.
NASA Astrophysics Data System (ADS)
Vishnoi, Gargi; Hielscher, Andreas H.; Ramanujam, Nirmala; Chance, Britton
2000-04-01
In this work experimental tissue phantoms and numerical models were developed to estimate photon migration through the fetal head in utero. The tissue phantoms incorporate a fetal head within an amniotic fluid sac surrounded by a maternal tissue layer. A continuous wave, dual-wavelength ((lambda) equals 760 and 850 nm) spectrometer was employed to make near-infrared measurements on the tissue phantoms for various source-detector separations, fetal-head positions, and fetal-head optical properties. In addition, numerical simulations of photon propagation were performed with finite-difference algorithms that provide solutions to the equation of radiative transfer as well as the diffusion equation. The simulations were compared with measurements on tissue phantoms to determine the best numerical model to describe photon migration through the fetal head in utero. Evaluation of the results indicates that tissue phantoms in which the contact between fetal head and uterine wall is uniform best simulates the fetal head in utero for near-term pregnancies. Furthermore, we found that maximum sensitivity to the head can be achieved if the source of the probe is positioned directly above the fetal head. By optimizing the source-detector separation, this signal originating from photons that have traveled through the fetal head can drastically be increased.
Torlakovic, Emina E.; Francis, Glenn; Garratt, John; Gilks, Blake; Hyjek, Elizabeth; Ibrahim, Merdol; Miller, Rodney; Nielsen, Søren; Petcu, Eugen B.; Swanson, Paul E.; Taylor, Clive R.; Vyberg, Mogens
2014-01-01
Standardization of controls, both positive and negative controls, is needed for diagnostic immunohistochemistry (dIHC). The use of IHC-negative controls, irrespective of type, although well established, is not standardized. As such, the relevance and applicability of negative controls continues to challenge both pathologists and laboratory budgets. Despite the clear theoretical notion that appropriate controls serve to demonstrate the sensitivity and specificity of the dIHC test, it remains unclear which types of positive and negative controls are applicable and/or useful in day-to-day clinical practice. There is a perceived need to provide “best practice recommendations” for the use of negative controls. This perception is driven not only by logistics and cost issues, but also by increased pressure for accurate IHC testing, especially when IHC is performed for predictive markers, the number of which is rising as personalized medicine continues to develop. Herein, an international ad hoc expert panel reviews classification of negative controls relevant to clinical practice, proposes standard terminology for negative controls, considers the total evidence of IHC specificity that is available to pathologists, and develops a set of recommendations for the use of negative controls in dIHC based on “fit-for-use” principles. PMID:24714041
Allaire, P; Hilton, E; Baloh, M; Maslen, E; Bearnson, G; Noh, D; Khanwilkar, P; Olsen, D
1998-06-01
A new centrifugal continuous flow ventricular assist device, the CFVAD III, which is fully magnetic bearing suspended, has been developed. It has only one moving part (the impeller), has no contact (magnetic suspension), is compact, and has minimal heating. A centrifugal impeller of 2 inch outer diameter is driven by a permanent magnet brushless DC motor. This paper discusses the design, construction, testing, and performance of the magnetic bearings in the unit. The magnetic suspension consists of an inlet side magnetic bearing and an outlet side magnetic bearing, each divided into 8 pole segments to control axial and radial displacements as well as angular displacements. The magnetic actuators are composed of several different materials to minimize size and weight while having sufficient load capacity to support the forces on the impeller. Flux levels in the range of 0.1 T are employed in the magnetic bearings. Self sensing electronic circuits (without physical sensors) are employed to determine the impellar position and provide the feedback control signal needed for the magnetic bearing control loops. The sensors provide position sensitivity of approximately 0.025 mm. A decentralized 5 axis controller has been developed using modal control techniques. Proportional integral derivative controls are used for each axis to levitate the magnetically supported impeller.
Recollection and Familiarity in Recognition Memory: Evidence from ROC Curves
ERIC Educational Resources Information Center
Heathcote, Andrew; Raymond, Frances; Dunn, John
2006-01-01
Does recognition memory rely on discrete recollection, continuous evidence, or both? Is continuous evidence sensitive to only the recency and duration of study (familiarity), or is it also sensitive to details of the study episode? Dual process theories assume recognition is based on recollection and familiarity, with only recollection providing…
Laboratory Diagnosis of Lyme Disease - Advances and Challenges
Marques, Adriana R.
2015-01-01
Synopsis Lyme disease is the most common tick-borne illness in the United States and Europe. Culture for B. burgdorferi is not routinely available. PCR can be helpful in synovial fluid of patients with Lyme arthritis. The majority of laboratory tests performed for the diagnosis of Lyme disease are based on detection of the antibody responses against B. burgdorferi in serum. The sensitivity of antibody-based tests increases with the duration of the infection, and patients who present very early in their illness are more likely to have a negative result. Patients with erythema migrans should receive treatment based on the clinical diagnosis. The current Centers for Disease Control and Prevention recommendations for serodiagnosis of Lyme disease is a 2-tiered algorithm, an initial enzyme immunoassay (EIA) followed by separate IgM and IgG Western blots if the first EIA test result is positive or borderline. The IgM result is only relevant for patients with illness duration of less than a month. While the 2-tier algorithm works well for later stages of the infection, it has low sensitivity during early infection. A major advance has been the discovery of VlsE and its C6 peptide as markers of antibody response in Lyme disease. Specificity is extremely important in Lyme disease testing, as the majority of tests are being performed in situations with low likelihood of the disease, a situation where a positive result is more likely to be a false positive. Current assays do not distinguish between active and inactive infection, and patients may continue to be seropositive for years. There is a need to simplify the testing algorithm for Lyme disease, improving sensitivity in early disease while still maintaining high specificity and providing information about the stage of infection. The development of a point of care assay and biomarkers for active infection would be major advances for the field. PMID:25999225
Intermittent pacemaker dysfunction caused by digital mobile telephones.
Naegeli, B; Osswald, S; Deola, M; Burkart, F
1996-05-01
This study was designed to evaluate possible interactions between digital mobile telephones and implanted pacemakers. Electromagnetic fields may interfere with normal pacemaker function. Development of bipolar sensing leads and modern noise filtering techniques have lessened this problem. However, it remains unclear whether these features also protect from high frequency noise arising from digital cellular phones. In 39 patients with an implanted pacemaker (14 dual-chamber [DDD], 8 atrial-synchronized ventricular-inhibited [VDD(R)] and 17 ventricular-inhibited [VVI(R)] pacemakers), four mobile phones with different levels of power output (2 and 8 W) were tested in the standby, dialing and operating mode. During continuous electrocardiographic monitoring, 672 tests were performed in each mode with the phones positioned over the pulse generator, the atrial and the ventricular electrode tip. The tests were carried out at different sensitivity settings and, where possible, in the unipolar and bipolar pacing modes as well. In 7 (18%) of 39 patients, a reproducible interference was induced during 26 (3.9%) of 672 tests with the operating phones in close proximity (<10 cm) to the pacemaker. In 22 dual-chamber (14 DDD, 8 VDD) pacemakers, atrial triggering occurred in 7 (2.8%) of 248 and ventricular inhibition in 5 (2.8%) of 176 tests. In 17 VVI(R) systems, pacemaker inhibition was induced in 14 (5.6%) of 248 tests. Interference was more likely to occur at higher power output of the phone and at maximal sensitivity of the pacemakers (maximal vs. nominal sensitivity, 6% vs. 1.8% positive test results, p = 0.009). When the bipolar and unipolar pacing modes were compared in the same patients, ventricular inhibition was induced only in the unipolar mode (12.5% positive test results, p = 0.0003). Digital mobile phones in close proximity to implanted pacemakers may cause intermittent pacemaker dysfunction with inappropriate ventricular tracking and potentially dangerous pacemaker inhibition.
Aberer, W; Komericki, P; Uter, W; Hausen, B M; Lessmann, H; Kränke, B; Geier, J; Schnuch, A
2003-08-01
The selection of the most important contact allergens is subject to a continuous change. Several factors may influence the sensitization rates and thus the decision, which substances to include in the standard series of the most frequent allergens. The Information Network of Departments of Dermatology adds substances of interest for a certain time period to the standard series in order to evaluate parameters such as sensitization rate, grade of reaction, and clinical relevance of positive reactions. In 6 testing periods starting in 1996, 13 test substances were evaluated. Due to the results, propolis, compositae mix, and bufexamac were included in the standard series in 1999, while lyral was added in 2002. Sorbitansesquioleat, dispers blue mix, and iodopropynyl butylcarbamate are under further discussion. Substances such as glutaraldehyde and p-aminoazobenzole should be tested in certain risk groups only, whereas the steroids budesonide and tixocortol should be tested when clinically suspected.
Yamashita, Kunihiko; Shinoda, Shinsuke; Hagiwara, Saori; Miyazaki, Hiroshi; Itagaki, Hiroshi
2015-12-01
The Organisation for Economic Co-operation and Development (OECD) Test Guidelines (TG) adopted the murine local lymph node assay (LLNA) and guinea pig maximization test (GPMT) as stand-alone skin sensitization test methods. However, unsaturated carbon-carbon double-bond and/or lipid acids afforded false-positive results more frequently in the LLNA compared to those in the GPMT and/or in human subjects. In the current study, oleic, linoleic, linolenic, undecylenic, fumaric, maleic, and succinic acid and squalene were tested in a modified LLNA with an elicitation phase (LLNA:DAE), and in a direct peptide reactivity assay (DPRA) to evaluate their skin-sensitizing potential. Oleic, linoleic, linolenic, undecylenic and maleic acid were positive in the LLNA:DAE, of which three, linoleic, linolenic, and maleic acid were positive in the DPRA. Furthermore, the results of the cross-sensitizing tests using four LLNA:DAE-positive chemicals were negative, indicating a chemical-specific elicitation response. In a previous report, the estimated concentration needed to produce a stimulation index of 3 (EC3) of linolenic acid, squalene, and maleic acid in the LLNA was < 10%. Therefore, these chemicals were classified as moderate skin sensitizers in the LLNA. However, the skin-sensitizing potential of all LLNA:DAE-positive chemicals was estimated as weak. These results suggested that oleic, linoleic, linolenic, undecylenic, and maleic acid had skin-sensitizing potential, and that the LLNA overestimated the skin-sensitizing potential compared to that estimated by the LLNA:DAE.
Sensitivity and daily quality control of a mobile PET/CT scanner operating in 3-dimensional mode.
Belakhlef, Abdelfatihe; Church, Clifford; Fraser, Ron; Lakhanpal, Suresh
2007-12-01
This study investigated the stability of the sensitivity of a mobile PET/CT scanner and tested a phantom experiment to improve on the daily quality control recommendations of the manufacturer. Unlike in-house scanners, mobile PET/CT devices are subjected to a harsher, continuously changing environment that can alter their performance. The parameter of sensitivity was investigated because it reflects directly on standardized uptake value, a key factor in cancer evaluation. A (68)Ge phantom of known activity concentration was scanned 6 times a month for 11 consecutive months using a mobile PET/CT scanner that operates in 3-dimensional mode only. The scans were acquired as 2 contiguous bed positions, with raw data obtained and reconstructed using parameters identical to those used for oncology patients, including CT-extracted attenuation coefficients and decay, scatter, geometry, and randoms corrections. After visual inspection of all reconstructed images, identical regions of interest were drawn on each image to obtain the activity concentration of individual slices. The original activity concentration was then decay-corrected to the scanning day, and the percentage sensitivity of the slice was calculated and graphed. The daily average sensitivity of the scanner, over 11 consecutive months, was also obtained and used to evaluate the stability of sensitivity. Our particular scanner showed a daily average sensitivity ranging from -8.6% to 6.5% except for one instance, when the sensitivity dropped by an unacceptable degree, 34.8%. Our 11-mo follow-up of a mobile PET/CT scanner demonstrated that its sensitivity remained within acceptable clinical limits except for one instance, when the scanner had to be serviced before patients could be imaged. To enhance our confidence in the uniformity of sensitivity across slices, we added a phantom scan to the daily quality control recommendations of the manufacturer.
Position of the American Dietetic Association: Promoting and supporting breastfeeding.
James, Delores C S; Dobson, Brenda
2005-05-01
It is the position of the American Dietetic Association (ADA) that exclusive breastfeeding provides optimal nutrition and health protection for the first 6 months of life, and breastfeeding with complementary foods for at least 12 months is the ideal feeding pattern for infants. Breastfeeding is also a public health strategy for improving infant and child health survival, improving maternal morbidity, controlling health care costs, and conserving natural resources. ADA emphasizes the essential role of dietetics professionals in promoting and supporting breastfeeding by providing up-to-date, practical information to pregnant and postpartum women, involving family and friends in breastfeeding education and counseling, removing institutional barriers to breastfeeding, collaborating with community organizations and others who promote and support breastfeeding, and advocating for policies that position breastfeeding as the norm for infant feeding. ADA also emphasizes its own role by providing up-to-date information to the public, encouraging empirical research, providing continuing education opportunities, providing cultural sensitivity and cultural competence training to dietetics professionals, and encouraging universities to review and update undergraduate and graduate training programs.
Ozen, N S; Ogunc, D; Mutlu, D; Ongut, G; Baysan, B O; Gunseren, F
2011-01-01
Differentiation of Staphylococcus aureus (S. aureus) from coagulase-negative staphylococci is very important in blood stream infections. Identification of S. aureus and coagulase-negative staphylococci (CoNS) from blood cultures takes generally 18-24 h after positive signaling on continuously monitored automated blood culture system. In this study, we evaluated the performance of tube coagulase test (TCT), slide agglutination test (Dry Spot Staphytect Plus), conventional polymerase chain reaction (PCR) and LightCycler Staphylococcus MGrade kit directly from blood culture bottles to achieve rapid identification of S. aureus by using the BACTEC 9240 blood culture system. A total of 129 BACTEC 9240 bottles growing gram-positive cocci suggesting Staphylococci were tested directly from blood culture broths (BCBs) with TCT, Dry Spot Staphytect Plus, conventional PCR and LightCycler Staphylococcus MGrade kit for rapid identification of S. aureus. The sensitivities of the tests were 99, 68, 99 and 100%, respectively. Our results suggested that 2 h TCT was found to be simple and inexpensive method for the rapid identification of S. aureus directly from positive blood cultures.
Clinical study to monitor dentinal hypersensitivity with episodic use of a desensitising dentifrice
Mason, Stephen; Kingston, Rose; Shneyer, Lucy; Harding, Máiréad
2017-01-01
Objectives/Aims: To evaluate continuous and episodic twice-daily usage regimens of a desensitising dentifrice containing 5% calcium sodium phosphosilicate (CSPS). Materials and Methods: In this exploratory, single-centre, randomised, examiner-blind study, subjects with dentinal hypersensitivity were randomised to continuous (24 weeks) use of a 5% CSPS-containing dentifrice or episodic use of the dentifrice comprising two 8-week treatment periods separated by 8 weeks′ use of a standard fluoride dentifrice. Sensitivity was assessed by tactile threshold (Yeaple probe) and evaporative (air) sensitivity (Schiff sensitivity score). Other measures included labelled magnitude scales to assess subjects′ responses to the evaporative stimulus, the Dentine Hypersensitivity Experience Questionnaire and a tooth sensitivity question. Results: Seventy-six subjects were randomised to continuous (n=38) or episodic (n=38) use. Small but statistically significant improvements from baseline in Schiff sensitivity scores were observed at weeks 8, 16 and 24 with both regimens (all P<0.05). Increases from baseline in tactile threshold were not statistically significant. No significant between-regimen difference was observed for any endpoint. No treatment-related adverse events were reported. Discussion: Dentifrice containing 5% CSPS improved dentinal hypersensitivity with both episodic and continuous twice-daily usage regimens over 24 weeks and was well tolerated. Conclusion: No performance differences were observed between the two usage regimens. PMID:29789771
Paulus, Elena M; Fabian, Timothy C; Savage, Stephanie A; Zarzaur, Ben L; Botta, Vandana; Dutton, Wesley; Croce, Martin A
2014-02-01
Aggressive screening to diagnose blunt cerebrovascular injury (BCVI) results in early treatment, leading to improved outcomes and reduced stroke rates. While computed tomographic angiography (CTA) has been widely adopted for BCVI screening, evidence of its diagnostic sensitivity is marginal. Previous work from our institution using 32-channel multidetector CTA in 684 patients demonstrated an inadequate sensitivity of 51% (Ann Surg. 2011,253: 444-450). Digital subtraction angiography (DSA) continues to be the reference standard of diagnosis but has significant drawbacks of invasiveness and resource demands. There have been continued advances in CT technology, and this is the first report of an extensive experience with 64-channel multidetector CTA. Patients screened for BCVI using CTA and DSA (reference) at a Level 1 trauma center during the 12-month period ending in May 2012 were identified. Results of CTA and DSA, complications, and strokes were retrospectively reviewed and compared. A total of 594 patients met criteria for BCVI screening and underwent both CTA and DSA. One hundred twenty-eight patients (22% of those screened) had 163 injured vessels: 99 (61%) carotid artery injuries and 64 (39%) vertebral artery injuries. Sixty-four-channel CTA demonstrated an overall sensitivity per vessel of 68% and specificity of 92%. The 52 false-negative findings on CTA were composed of 34 carotid artery injuries and 18 vertebral artery injuries; 32 (62%) were Grade I injuries. Overall, positive predictive value was 36.2%, and negative predictive value was 97.5%. Six procedure-related complications (1%) occurred with DSA, including two iatrogenic dissections and one stroke. Sixty-four-channel CTA demonstrated a significantly improved sensitivity of 68% versus the 51% previously reported for the 32-channel CTA (p = 0.0075). Sixty-two percent of the false-negative findings occurred with low-grade injuries. Considering complications, cost, and resource demand associated with DSA, this study suggests that 64-channel CTA may replace DSA as the primary screening tool for BCVI. Diagnostic study, level III.
Radiation sensitive devices and systems for detection of radioactive materials and related methods
Kotter, Dale K
2014-12-02
Radiation sensitive devices include a substrate comprising a radiation sensitive material and a plurality of resonance elements coupled to the substrate. Each resonance element is configured to resonate responsive to non-ionizing incident radiation. Systems for detecting radiation from a special nuclear material include a radiation sensitive device and a sensor located remotely from the radiation sensitive device and configured to measure an output signal from the radiation sensitive device. In such systems, the radiation sensitive device includes a radiation sensitive material and a plurality of resonance elements positioned on the radiation sensitive material. Methods for detecting a presence of a special nuclear material include positioning a radiation sensitive device in a location where special nuclear materials are to be detected and remotely interrogating the radiation sensitive device with a sensor.
Graham, Rebecca A; Weems, Carl F
2015-07-01
A substantial body of literature suggests that anxiety sensitivity is a risk factor for the development of anxiety problems and research has now begun to examine the links between parenting, parent anxiety sensitivity and their child's anxiety sensitivity. However, the extant literature has provided mixed findings as to whether parent anxiety sensitivity is associated with child anxiety sensitivity, with some evidence suggesting that other factors may influence the association. Theoretically, specific parenting behaviors may be important to the development of child anxiety sensitivity and also in understanding the association between parent and child anxiety sensitivity. In this study, 191 families (n = 255 children and adolescents aged 6-17 and their parents) completed measures of child anxiety sensitivity (CASI) and parenting (APQ-C), and parents completed measures of their own anxiety sensitivity (ASI) and their parenting (APQ-P). Corporal punishment was associated with child anxiety sensitivity and the child's report of their parent's positive parenting behaviors moderated the association between parent and child anxiety sensitivity. The child's gender was also found to moderate the association between parent and child anxiety sensitivity, such that there was a positive association between girls' and their parents anxiety sensitivity and a negative association in boys. The findings advance the understanding of child anxiety sensitivity by establishing a link with corporal punishment and by showing that the association between parent and child anxiety sensitivity may depend upon the parenting context and child's gender.
CONTINUOUSLY SENSITIVE BUBBLE CHAMBER
Good, R.H.
1959-08-18
A radiation detector of the bubble chamber class is described which is continuously sensitive and which does not require the complex pressure cycling equipment characteristic of prior forms of the chamber. The radiation sensitive element is a gas-saturated liquid and means are provided for establishing a thermal gradient across a region of the liquid. The gradient has a temperature range including both the saturation temperature of the liquid and more elevated temperatures. Thus a supersaturated zone is created in which ionizing radiations may give rise to visible gas bubbles indicative of the passage of the radiation through the liquid. Additional means are provided for replenishing the supply of gas-saturated liquid to maintaincontinuous sensitivity.
Lormeau, B; Aurousseau, M H; Valensi, P; Paries, J; Attali, J R
1997-09-01
A defect in the fibrinolytic system results from an increase in type 1 plasminogen activator inhibitor (PAI-1) in diabetes. It can be considered an independent risk factor for the development of cardiovascular disease. In obese and type II diabetic patients, plasma PAI-1 level correlates with fasting insulinemia. However, during the euglycemic clamp, acute hyperinsulinemia does not increase PAI-1 production. The present study was undertaken to investigate the effect of optimized glycemic control by continuous subcutaneous insulin infusion (CSII) on the hypofibrinolytic state for 14 days in 16 type II diabetic patients with poor metabolic control despite maximal oral antidiabetic treatment. Plasma PAI-1 activity levels decreased from 13.38 +/- 2.85 IU/mL to 6.77 +/- 1.81 IU/mL (P = .002) during CSII, along with a concurrent improvement in insulin sensitivity (index obtained by basal glycemia-nadir glycemia/basal glycemia) during the insulin sensitivity test (0.121 +/- 0.03 v 0.057 +/- 0.02, P = .02). These results suggest that insulin resistance rather than hyperinsulinism may be involved in the hypofibrinolytic state in type II diabetic patients. The positive correlation between the changes in triglycerides and in PAI-1 activity (r = .589, P = .026) strongly suggests a role for triglycerides in the impairment of fibrinolysis, which could be a link between insulin resistance and hypofibrinolysis.
NASA Astrophysics Data System (ADS)
Dannenberg, M. P.; Wise, E.
2017-12-01
Much of the precipitation delivered to western North America arrives during the October to March cool season via midlatitude Pacific storm tracks, which may shift in the future due to climate change. Using historical climate, tree-ring, and remote sensing data, we assessed the sensitivity of western North American hydroclimate and ecosystems to the position and intensity of cool-season Pacific storm tracks. From 1980-2014, mean annual cool-season storm tracks entered western North America between approximately 41°N to 53°N, with substantial interannual variability in both the position and intensity of the storm tracks. We examined relationships between storm tracks and two hydroclimatic variables: the cool-season standardized precipitation-evapotranspiration index and April snow water equivalent. We also assessed how historical storm track variability affected ecosystems using forest growth estimates from a large tree-ring network as well as land surface phenology and wildfire estimates from AVHRR and Landsat, respectively. Cool-season moisture supply and snowpack responded strongly to storm track position, with positive correlations to storm track latitude in eastern Alaska and northwestern Canada but negative correlations in the northwestern U.S. These hydroclimatic impacts were largely driven by the latitudinal position of storm tracks during the "shoulder" seasons (i.e., autumn and early spring). Ecosystems of the western U.S. tended to be greener and more productive following winters with south-shifted storm tracks, while Canadian ecosystems were greener in years when the cool-season storm track was shifted to the north. On average, larger areas of the northwestern U.S. were burned by moderate to high severity wildfires when storm tracks were displaced north, and the average burn area per fire also tended to be higher in years with north-shifted storm tracks. Assuming that these historical relationships continue to hold under future climate scenarios, our results suggest that projected long-term shifts of Pacific storm tracks over the 21st century would likely alter hydroclimatic and ecological regimes in western North America, particularly in the northwestern U.S., where moisture supply and ecosystem processes are highly sensitive to the position of cool-season storm tracks.
Vandeweghe, Laura; Vervoort, Leentje; Verbeken, Sandra; Moens, Ellen; Braet, Caroline
2016-01-01
It has recently been suggested that individual differences in Reward Sensitivity and Punishment Sensitivity may determine how children respond to food. These temperamental traits reflect activity in two basic brain systems that respond to rewarding and punishing stimuli, respectively, with approach and avoidance. Via parent-report questionnaires, we investigate the associations of the general motivational temperamental traits Reward Sensitivity and Punishment Sensitivity with Food Approach and Food Avoidance in 98 preschool children. Consistent with the conceptualization of Reward Sensitivity in terms of approach behavior and Punishment Sensitivity in terms of avoidance behavior, Reward Sensitivity was positively related to Food Approach, while Punishment Sensitivity was positively related to Food Avoidance. Future research should integrate these perspectives (i.e., general temperamental traits Reward Sensitivity and Punishment Sensitivity, and Food Approach and Avoidance) to get a better understanding of eating behavior and related body weight. PMID:27445898
Yamashita, Kunihiko; Shinoda, Shinsuke; Hagiwara, Saori; Itagaki, Hiroshi
2014-02-01
We developed a new local lymph node assay (LLNA) that includes the elicitation phase termed LLNA:DAE for discrimination of borderline-positive chemicals as classified by the LLNA modified by Daicel based on ATP content (LLNA:DA) and for cross-sensitization testing. Although the LLNA:DA method could help identify skin sensitizers, some skin irritants classified as non-sensitizers by the LLNA were classified as borderline positive. In addition, the evaluation for the cross-sensitization potential between chemicals was impossible. In the LLNA:DAE procedure, test group of mice received four applications of chemicals on the dorsum of the right ear for induction and one application on the dorsum of the left ear for elicitation. Control group of mice received one chemical application on the dorsum of the left ear. We evaluated the sensitizing potential by comparing the weights of the lymph nodes from the left ears between the two groups. The results of using the LLNA:DAE method to examine 24 chemicals, which contained borderline-positive chemicals, were consistent with those from the LLNA method, except for nickel chloride (NiCl2). Two chemical pairs, 2,4-dinitrochlorobenzene (DNCB) with 2,4-dinitrofluorobenzene (DNFB) and hydroquinone (HQ) with p-benzoquinone (p-BQ), showed clear cross-sensitization with each other, while another chemical pair, DNFB with hexylcinnamic aldehyde (HCA) did not. Taken together, our results suggest that the LLNA:DAE method is useful for discriminating borderline-positive chemicals and for determining chemical cross-sensitization.
Paltoglou, George; Schoina, Maria; Valsamakis, George; Salakos, Nicolaos; Avloniti, Alexandra; Chatzinikolaou, Athanasios; Margeli, Alexandra; Skevaki, Chrysanthi; Papagianni, Maria; Kanaka-Gantenbein, Christina; Papassotiriou, Ioannis; Chrousos, George P; Fatouros, Ioannis G; Mastorakos, George
2017-03-01
Presumed interrelationships among deleterious aspects of adipose tissue metabolism, inflammation, and cellular oxidative stress could be influenced by pubertal hormonal changes. They were investigated in pre- and early pubertal normal-weight and obese boys before and after an exercise bout employed as an energy demanding stimulator. Cross-sectional study. Seventy-six healthy pre- (mean ± SD, 10.6 ± 0.2 years old, 28 normal-weight, and 11 obese) and early-(11.4 ± 0.2 years old, 25 normal-weight, and 12 obese) pubertal boys, were blood-sampled before and after a bout of exercise at 70% VO 2 max. Leptin, adiponectin, markers of inflammation (high-sensitivity C-reactive protein, high sensitivity IL-6), pro- (thiobarbitouric acid reactive substances, protein carbonyls) and anti- (glutathione, oxidized glutathione, glutathione peroxidase, catalase, total antioxidant capacity) oxidation were measured. Baseline and post-exercise adiponectin was greater and leptin and high-sensitivity C-reactive protein were lower in normal-weight than in obese pre- and early pubertal boys, while high sensitivity IL-6 was greater in obese than in normal-weight pre-pubertal boys. In pre-pubertal obese boys: at baseline, high-sensitivity C-reactive protein correlated negatively with catalase; high sensitivity IL-6 correlated positively with protein carbonyls; Δ (difference during exercise) adiponectin correlated positively with Δcatalase. In all boys: at baseline, high sensitivity IL-6 correlated positively with leptin and was the best negative and the second best positive predictor for post-exercise glutathione/oxidized glutathione and protein carbonyls, respectively; leptin was the best negative predictor for post-exercise glutathione; waist to height ratio was the best positive predictor for post-exercise thiobarbitouric acid reactive substances; body mass index z-score and adiponectin were, respectively, the best positive predictor for post-exercise protein carbonyls and catalase. In all subjects, leptin and adiponectin predict negatively and positively anti-oxidation, respectively, while high sensitivity IL-6 predicts positively and negatively pro- and anti-oxidation, respectively. High-sensitivity C-reactive protein is increased and negatively associated with anti-oxidation in pre-pubertal obese boys, suggesting that childhood obesity is associated with aseptic inflammation and oxidative stress.
Drinking sucrose or saccharin enhances sensitivity of rats to quinpirole-induced yawning
Serafine, Katherine M; Bentley, Todd A; Kilborn, Dylan J; Koek, Wouter; France, Charles P
2015-01-01
Diet can impact sensitivity of rats to some of the behavioral effects of drugs acting on dopamine systems. The current study tested whether continuous access to sucrose is necessary to increase yawning induced by the dopamine receptor agonist quinpirole, or if intermittent access is sufficient. These studies also tested whether sensitivity to quinpirole-induced yawning increases in rats drinking the non-caloric sweetener saccharin. Dose-response curves (0.0032–0.32 mg/kg) for quinpirole-induced yawning were determined once weekly in rats with free access to standard chow and either continuous access to water, 10% sucrose solution, or 0.1% saccharin solution, or intermittent access to sucrose or saccharin (i.e., 2 days per week with access to water on other days). Cumulative doses of quinpirole increased then decreased yawning, resulting in an inverted U-shaped dose-response curve. Continuous or intermittent access to sucrose enhanced sensitivity to quinpirole-induced yawning. Continuous, but not intermittent, access to saccharin also enhanced sensitivity to quinpirole-induced yawning. In all groups, pretreatment with the selective D3 receptor antagonist PG 01037 shifted the ascending limb of the quinpirole dose-response curve to the right, while pretreatment with the selective D2 receptor antagonist L-741626 shifted the descending limb to the right. These results suggest that even intermittent consumption of diets containing highly palatable substances (e.g. sucrose) alters sensitivity to drugs acting on dopamine systems in a manner that could be important in vulnerability to abuse drugs. PMID:26189020
Narayanappa, D; Sripathi, Rachana; Jagdishkumar, K; Rajani, H S
2010-04-01
We compared the sensitivity and specificity of Typhidot-M and Widal test with blood culture (gold standard) for diagnosing typhoid fever in 105 children aged 1-15 years admitted with clinical suspicion of typhoid fever. Of the 105 cases, blood culture was positive for S.typhi in 41 (39%) children, Widal test was positive in 48 (45.7%) and Typhidot-M was positive in 78 (74.3%) cases. Sensitivity and specificity of Typhidot-M was 92.6% and 37.5% while sensitivity and specificity of Widal test was 34.1% and 42.8%, respectively. In children with fever of less than 7 days duration, Typhidot-M was positive in 97%, compared to 24.2% by Widal test. Typhidot-M is a simple and sensitive test for early diagnosis of typhoid fever in children.
2006 Global Demilitarization Symposium Volume 1 Presentations
2006-05-04
produce inorganic crystals in continuous-reaction mode: Continuous synthesis of CdSe–ZnS composite nanoparticles in a microfluidic reactor, Hongzhi...crystallize lead azide nanoparticles , and to grow them into dextrinated microparticles; Point of Application Microfluidic Synthesis of Sensitive...National Laboratory Point of Application Synthesis of Sensitive Explosive Mr. Karl Wally, Sandia National Laboratories Session III- A Session
Telerobotic rendezvous and docking vision system architecture
NASA Technical Reports Server (NTRS)
Gravely, Ben; Myers, Donald; Moody, David
1992-01-01
This research program has successfully demonstrated a new target label architecture that allows a microcomputer to determine the position, orientation, and identity of an object. It contains a CAD-like database with specific geometric information about the object for approach, grasping, and docking maneuvers. Successful demonstrations were performed selecting and docking an ORU box with either of two ORU receptacles. Small, but significant differences were seen in the two camera types used in the program, and camera sensitive program elements have been identified. The software has been formatted into a new co-autonomy system which provides various levels of operator interaction and promises to allow effective application of telerobotic systems while code improvements are continuing.
Nathan, B; Appiah, J; Saunders, P; Heron, D; Nichols, T; Brum, R; Alexander, S; Baraitser, P; Ison, C
2015-03-01
In the UK, despite its low sensitivity, wet mount microscopy is often the only method of detecting Trichomonas vaginalis infection. A study was conducted in symptomatic women to compare the performance of five methods for detecting T. vaginalis: an in-house polymerase chain reaction (PCR); Aptima T. vaginalis kit; OSOM ®Trichomonas Rapid Test; culture and microscopy. Symptomatic women underwent routine testing; microscopy and further swabs were taken for molecular testing, OSOM and culture. A true positive was defined as a sample that was positive for T. vaginalis by two or more different methods. Two hundred and forty-six women were recruited: 24 patients were positive for T. vaginalis by two or more different methods. Of these 24 patients, 21 patients were detected by real-time PCR (sensitivity 88%); 22 patients were detected by the Aptima T. vaginalis kit (sensitivity 92%); 22 patients were detected by OSOM (sensitivity 92%); nine were detected by wet mount microscopy (sensitivity 38%); and 21 were detected by culture (sensitivity 88%). Two patients were positive by just one method and were not considered true positives. All the other detection methods had a sensitivity to detect T. vaginalis that was significantly greater than wet mount microscopy, highlighting the number of cases that are routinely missed even in symptomatic women if microscopy is the only diagnostic method available. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Young, Ewa; Zimerson, Erik; Bruze, Magnus; Svedman, Cecilia
2016-02-01
The results from a previous study indicated the presence of several possible sensitizers formed during oxidation of the potent sensitizer p-phenylenediamine (PPD) to which PPD-sensitized patients might react, in various patterns. To extract and analyse a yellow spot from a thin-layer chromatogram with oxidized PPD, to which 6 of 14 (43%) PPD-positive patients had reacted in a previous study, in order to identify potential sensitizer(s) and to patch test this/these substance(s) in the 14 PPD-positive patients. The yellow spot was extracted from a thin-layer chromatogram of oxidized PPD, and two substances, suspected to be allergens, were identified by analysis with gas chromatography mass spectrometry (GCMS). The 14 PPD-positive patients, who had been previously tested with the thin-layer chromatogram of oxidized PPD, participated in the investigation, and were tested with dilutions of the two substances. GCMS analysis identified 4-nitroaniline and 4,4'-azodianiline in the yellow spot. Of the 14 PPD-positive test patients, 5 (36%) reacted to 4-nitroaniline and 9 (64%) reacted to 4,4'-azodianiline. The results show that 4-nitroaniline and 4,4'-azodianiline, formed during oxidation of PPD, are potent sensitizers. PPD-sensitized patients react to a high extent to concentrations equimolar to PPD of 4-nitroaniline and 4,4'-azodianiline. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Thomas, Patricia E; LeFlore, Judy
2013-01-01
Infants born prematurely with respiratory distress syndrome are at high risk for complications from mechanical ventilation. Strategies are needed to minimize their days on the ventilator. The purpose of this study was to compare extubation success rates in infants treated with 2 different types of continuous positive airway pressure devices. A retrospective cohort study design was used. Data were retrieved from electronic medical records for patients in a large, metropolitan, level III neonatal intensive care unit. A sample of 194 premature infants with respiratory distress syndrome was selected, 124 of whom were treated with nasal intermittent positive pressure ventilation and 70 with bi-level variable flow nasal continuous positive airway pressure (bi-level nasal continuous positive airway pressure). Infants in both groups had high extubation success rates (79% of nasal intermittent positive pressure ventilation group and 77% of bi-level nasal continuous positive airway pressure group). Although infants in the bi-level nasal continuous positive airway pressure group were extubated sooner, there was no difference in duration of oxygen therapy between the 2 groups. Promoting early extubation and extubation success is a vital strategy to reduce complications of mechanical ventilation that adversely affect premature infants with respiratory distress syndrome.
van de Groep, Kirsten; Bos, Martine P; Savelkoul, Paul H M; Rubenjan, Anna; Gazenbeek, Christel; Melchers, Willem J G; van der Poll, Tom; Juffermans, Nicole P; Ong, David S Y; Bonten, Marc J M; Cremer, Olaf L
2018-04-26
Molecular tests may enable early adjustment of antimicrobial therapy and be complementary to blood culture (BC) which has imperfect sensitivity in critically ill patients. We evaluated a novel multiplex real-time PCR assay to diagnose bloodstream pathogens directly in whole blood samples (BSI-PCR). BSI-PCR included 11 species- and four genus-specific PCRs, a molecular Gram-stain PCR, and two antibiotic resistance markers. We collected 5 mL blood from critically ill patients simultaneously with clinically indicated BC. Microbial DNA was isolated using the Polaris method followed by automated DNA extraction. Sensitivity and specificity were calculated using BC as reference. BSI-PCR was evaluated in 347 BC-positive samples (representing up to 50 instances of each pathogen covered by the test) and 200 BC-negative samples. Bacterial species-specific PCR sensitivities ranged from 65 to 100%. Sensitivity was 26% for the Gram-positive PCR, 32% for the Gram-negative PCR, and ranged 0 to 7% for yeast PCRs. Yeast detection was improved to 40% in a smaller set-up. There was no overall association between BSI-PCR sensitivity and time-to-positivity of BC (which was highly variable), yet Ct-values were lower for true-positive versus false-positive PCR results. False-positive results were observed in 84 (4%) of the 2200 species-specific PCRs in 200 culture-negative samples, and ranged from 0 to 6% for generic PCRs. Sensitivity of BSI-PCR was promising for individual bacterial pathogens, but still insufficient for yeasts and generic PCRs. Further development of BSI-PCR will focus on improving sensitivity by increasing input volumes and on subsequent implementation as a bedside test.
Plumb, Andrew A; Halligan, Steve; Pendsé, Douglas A; Taylor, Stuart A; Mallett, Susan
2014-05-01
CT colonography (CTC) is recommended after positive faecal occult blood testing (FOBt) when colonoscopy is incomplete or infeasible. We aimed to estimate the sensitivity and specificity of CTC for colorectal cancer and adenomatous polyps following positive FOBt via systematic review. The MEDLINE, EMBASE, AMED and Cochrane Library databases were searched for CTC studies reporting sensitivity and specificity for colorectal cancer and adenomatous polyps. Included subjects had tested FOBt-positive by guaiac or immunochemical methods. Per-patient detection rates were summarized via forest plots. Meta-analysis of sensitivity and specificity was conducted using a bivariate random effects model and the average operating point calculated. Of 538 articles considered, 5 met inclusion criteria, describing results from 622 patients. Research study quality was good. CTC had a high per-patient average sensitivity of 88.8 % (95 % CI 83.6 to 92.5 %) for ≥6 mm adenomas or colorectal cancer, with low between-study heterogeneity. Specificity was both more heterogeneous and lower, at an average of 75.4 % (95 % CI 58.6 to 86.8 %). Few studies have investigated CTC in FOBt-positive individuals. CTC is sensitive at a ≥6 mm threshold but specificity is lower and variable. Despite the limited data, these results suggest that CTC may adequately substitute for colonoscopy when the latter is undesirable. • FOBt is the most common mass screening test for colorectal cancer. • Few studies evaluate CT colonography after positive FOBt. • CTC is approximately 89 % sensitive for ≥6 mm adenomas/cancer in this setting. • Specificity is lower, at approximately 75 %, and more variable. • CT colonography is a good alternative when colonoscopy is undesirable.
Bratton, Daniel J; Gaisl, Thomas; Schlatzer, Christian; Kohler, Malcolm
2015-11-01
Excessive daytime sleepiness is the most important symptom of obstructive sleep apnoea and can affect work productivity, quality of life, and the risk of road traffic accidents. We aimed to quantify the effects of the two main treatments for obstructive sleep apnoea (continuous positive airway pressure and mandibular advancement devices) on daytime sleepiness and to establish predictors of response to continuous positive airway pressure. We searched MEDLINE and the Cochrane Library from inception to May 31, 2015, to identify randomised controlled trials comparing the effects of continuous positive airway pressure, mandibular advancement devices or an inactive control (eg, placebo or no treatment) on the Epworth Sleepiness Scale (ESS, range 0-24 points) in patients with obstructive sleep apnoea. We did a network meta-analysis using multivariate random-effects meta-regression to assess the effect of each treatment on ESS. We used meta-regression to assess the association of the reported effects of continuous positive airway pressure versus inactive controls with the characteristics of trials and their risk of bias. We included 67 studies comprising 6873 patients in the meta-analysis. Compared with an inactive control, continuous positive airway pressure was associated with a reduction in ESS score of 2·5 points (95% CI 2·0-2·9) and mandibular advancement devices of 1·7 points (1·1-2·3). We estimated that, on average, continuous positive airway pressure reduced the ESS score by a further 0·8 points compared with mandibular advancement devices (95% CI 0·1-1·4; p=0·015). However, there was a possibility of publication bias in favour of continuous positive airway pressure that might have resulted in this difference. We noted no evidence that studies reporting higher continuous positive airway pressure adherence also reported larger treatment effects (p=0·70). Continuous positive airway pressure and mandibular advancement devices are effective treatments for reducing daytime sleepiness in patients with obstructive sleep apnoea. Continuous positive airway pressure seemed to be a more effective treatment than mandibular advancement devices, and had an increasingly larger effect in more severe or sleepier obstructive sleep apnoea patients when compared with inactive controls. However, mandibular advancement devices are an effective alternative treatment should continuous positive airway pressure not be tolerated. Swiss National Science Foundation and the University of Zurich Clinical Research Priority Program Sleep and Health. Copyright © 2015 Elsevier Ltd. All rights reserved.
CAMEA—A novel multiplexing analyzer for neutron spectroscopy
NASA Astrophysics Data System (ADS)
Groitl, Felix; Graf, Dieter; Birk, Jonas Okkels; Markó, Márton; Bartkowiak, Marek; Filges, Uwe; Niedermayer, Christof; Rüegg, Christian; Rønnow, Henrik M.
2016-03-01
The analyzer detector system continuous angle multiple energy analysis will be installed on the cold-neutron triple-axis spectrometer RITA-2 at SINQ, PSI. CAMEA is optimized for efficiency in the horizontal scattering plane enabling rapid and detailed mapping of excitations. As a novelty the design employs a series of several sequential upward scattering analyzer arcs. Each arc is set to a different, fixed, final energy and scatters neutrons towards position sensitive detectors. Thus, neutrons with different final energies are recorded simultaneously over a large angular range. In a single data-acquisition many entire constant-energy lines in the horizontal scattering plane are recorded for a quasi-continuous angular coverage of about 60°. With a large combined coverage in energy and momentum, this will result in a very efficient spectrometer, which will be particularly suited for parametric studies under extreme conditions with restrictive sample environments (high field magnets or pressure cells) and for small samples of novel materials. In this paper we outline the concept and the specifications of the instrument currently under construction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Groitl, Felix, E-mail: felix.groitl@psi.ch; Paul Scherrer Institute, Laboratory for Neutron Scattering and Imaging, 5232 Villigen; Graf, Dieter
The analyzer detector system continuous angle multiple energy analysis will be installed on the cold-neutron triple-axis spectrometer RITA-2 at SINQ, PSI. CAMEA is optimized for efficiency in the horizontal scattering plane enabling rapid and detailed mapping of excitations. As a novelty the design employs a series of several sequential upward scattering analyzer arcs. Each arc is set to a different, fixed, final energy and scatters neutrons towards position sensitive detectors. Thus, neutrons with different final energies are recorded simultaneously over a large angular range. In a single data-acquisition many entire constant-energy lines in the horizontal scattering plane are recorded formore » a quasi-continuous angular coverage of about 60°. With a large combined coverage in energy and momentum, this will result in a very efficient spectrometer, which will be particularly suited for parametric studies under extreme conditions with restrictive sample environments (high field magnets or pressure cells) and for small samples of novel materials. In this paper we outline the concept and the specifications of the instrument currently under construction.« less
NASA Astrophysics Data System (ADS)
Douch, Karim; Müller, Jürgen; Heinzel, Gerhard; Wu, Hu
2017-04-01
The successful GRACE mission and its far-reaching benefits have highlighted the interest to continue and extend the mapping of the Earth's time-variable gravitational field with follow-on missions and ideally a higher spatiotemporal resolution. Here, we would like to put forward satellite gravitational gradiometry as an alternative solution to satellite-to-satellite tracking for future missions. Besides the higher sensitivity to smaller scales compared to GRACE-like missions, a gradiometry mission would only require one satellite and would provide a direct estimation of a functional of the gravitational field. GOCE, the only gradiometry mission launched so far, was not sensitive enough to map the time-variable part of the gravity field. However, the unprecedented precision of the state-of-the-art optical metrology system on-board the LISA PATHFINDER satellite has opened the way to more performant space inertial sensors. We will therefore examine whether it is technically possible to go beyond GOCE performances and to quantify to what extent the time-variable gravitational field could be determined. First, we derive the requirements on the knowledge of the attitude and the position of the satellite and on the measured gradients in terms of sensitivity and calibration accuracy for a typical repeat low-orbit. We conclude in particular that a noise level smaller than 0.1 mE/√Hz- is required in the measurement bandwidth [5x10-4 ; 10-2]Hz so as to be sensitive to the time-variable gravity signal. We introduce then the design and characteristics of the new gradiometer concept and give an assessment of its noise budget. Contrary to the GOCE electrostatic gradiometer, the position of the test-mass in the accelerometer is measured here by laser interferometry rather than by a capacitive readout system, which improves the overall measurement chain. Finally, the first results of a performance analysis carried out thanks to an end-to-end simulator are discussed and compared to the previously defined requirements.
Rosenstreich, David L; Moday, Heather J; Hudes, Golda
2003-01-01
Asthma is an environmental disease that is caused in most patients by the continual inhalation of allergens. There are many different types of indoor and outdoor allergens and the exact sensitivities to these vary between people. Thorough and continuous allergen removal is the safest and most cost-effective means of treating asthma and should be undertaken in every patient. Environmental control should be done by every asthmatic regardless of perceived or actual allergic sensitivity, both because allergy testing has a significant false-negative rate because prolonged exposure to allergen will produce new sensitivities.
Masch, William R; Cohan, Richard H; Ellis, James H; Dillman, Jonathan R; Rubin, Jonathan M; Davenport, Matthew S
2016-02-01
The purpose of this study was to determine the clinical effectiveness of prospectively reported sonographic twinkling artifact for the diagnosis of renal calculus in patients without known urolithiasis. All ultrasound reports finalized in one health system from June 15, 2011, to June 14, 2014, that contained the words "twinkle" or "twinkling" in reference to suspected renal calculus were identified. Patients with known urolithiasis or lack of a suitable reference standard (unenhanced abdominal CT with ≤ 2.5-mm slice thickness performed ≤ 30 days after ultrasound) were excluded. The sensitivity, specificity, and positive likelihood ratio of sonographic twinkling artifact for the diagnosis of renal calculus were calculated by renal unit and stratified by two additional diagnostic features for calcification (echogenic focus, posterior acoustic shadowing). Eighty-five patients formed the study population. Isolated sonographic twinkling artifact had sensitivity of 0.78 (82/105), specificity of 0.40 (26/65), and a positive likelihood ratio of 1.30 for the diagnosis of renal calculus. Specificity and positive likelihood ratio improved and sensitivity declined when the following additional diagnostic features were present: sonographic twinkling artifact and echogenic focus (sensitivity, 0.61 [64/105]; specificity, 0.65 [42/65]; positive likelihood ratio, 1.72); sonographic twinkling artifact and posterior acoustic shadowing (sensitivity, 0.31 [33/105]; specificity, 0.95 [62/65]; positive likelihood ratio, 6.81); all three features (sensitivity, 0.31 [33/105]; specificity, 0.95 [62/65]; positive likelihood ratio, 6.81). Isolated sonographic twinkling artifact has a high false-positive rate (60%) for the diagnosis of renal calculus in patients without known urolithiasis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cuddy-Walsh, SG; University of Ottawa Heart Institute; Wells, RG
2014-08-15
Myocardial perfusion imaging (MPI) with Single Photon Emission Computed Tomography (SPECT) is invaluable in the diagnosis and management of heart disease. It provides essential information on myocardial blood flow and ischemia. Multi-pinhole dedicated cardiac-SPECT cameras offer improved count sensitivity, and spatial and energy resolutions over parallel-hole camera designs however variable sensitivity across the field-of-view (FOV) can lead to position-dependent noise variations. Since MPI evaluates differences in the signal-to-noise ratio, noise variations in the camera could significantly impact the sensitivity of the test for ischemia. We evaluated the noise characteristics of GE Healthcare's Discovery NM530c camera with a goal of optimizingmore » the accuracy of our patient assessment and thereby improving outcomes. Theoretical sensitivity maps of the camera FOV, including attenuation effects, were estimated analytically based on the distance and angle between the spatial position of a given voxel and each pinhole. The standard deviation in counts, σ was inferred for each voxel position from the square root of the sensitivity mapped at that position. Noise was measured experimentally from repeated (N=16) acquisitions of a uniform spherical Tc-99m-water phantom. The mean (μ) and standard deviation (σ) were calculated for each voxel position in the reconstructed FOV. Noise increased ∼2.1× across a 12 cm sphere. A correlation of 0.53 is seen when experimental noise is compared with theory suggesting that ∼53% of the noise is attributed to the combined effects of attenuation and the multi-pinhole geometry. Further investigations are warranted to determine the clinical impact of the position-dependent noise variation.« less
Thermal effects on bacterial bioaerosols in continuous air flow.
Jung, Jae Hee; Lee, Jung Eun; Kim, Sang Soo
2009-08-01
Exposure to bacterial bioaerosols can have adverse effects on health, such as infectious diseases, acute toxic effects, and allergies. The search for ways of preventing and curing the harmful effects of bacterial bioaerosols has created a strong demand for the study and development of an efficient method of controlling bioaerosols. We investigated the thermal effects on bacterial bioaerosols of Escherichia coli and Bacillus subtilis by using a thermal electric heating system in continuous air flow. The bacterial bioaerosols were exposed to a surrounding temperature that ranged from 20 degrees C to 700 degrees C for about 0.3 s. Both E. coli and B. subtilis vegetative cells were rendered more than 99.9% inactive at 160 degrees C and 350 degrees C of wall temperature of the quartz tube, respectively. Although the data on bacterial injury showed that the bacteria tended to sustain greater damage as the surrounding temperature increased, Gram-negative E. coli was highly sensitive to structural injury but Gram-positive B. subtilis was slightly more sensitive to metabolic injury. In addition, the inactivation of E. coli endotoxins was found to range from 9.2% (at 200 degrees C) to 82.0% (at 700 degrees C). However, the particle size distribution and morphology of both bacterial bioaerosols were maintained, despite exposure to a surrounding temperature of 700 degrees C. Our results show that thermal heating in a continuous air flow can be used with short exposure time to control bacterial bioaerosols by rendering the bacteria and endotoxins to a large extent inactive. This result could also be useful for developing more effective thermal treatment strategies for use in air purification or sterilization systems to control bioaerosols.
Mata, Fernanda; Verdejo-Roman, Juan; Soriano-Mas, Carles; Verdejo-Garcia, Antonio
2015-10-01
This study was aimed to examine if adolescent obesity is associated with alterations of insula function as indexed by differential correlations between insula activation and perception of interoceptive feedback versus external food cues. We hypothesized that, in healthy weight adolescents, insula activation will positively correlate with interoceptive sensitivity, whereas in excess weight adolescents, insula activation will positively correlate with sensitivity towards external cues. Fifty-four adolescents (age range 12-18), classified in two groups as a function of BMI, excess weight (n = 22) and healthy weight (n = 32), performed the Risky-Gains task (sensitive to insula function) inside an fMRI scanner, and completed the heartbeat perception task (measuring interoceptive sensitivity) and the Dutch Eating Behaviour Questionnaire (measuring external eating as well as emotional eating and restraint) outside the scanner. We found that insula activation during the Risky-Gains task positively correlated with interoceptive sensitivity and negatively correlated with external eating in healthy weight adolescents. Conversely, in excess weight adolescents, insula activation positively correlated with external eating and negatively correlated with interoceptive sensitivity, arguably reflecting obesity related neurocognitive adaptations. In excess weight adolescents, external eating was also positively associated with caudate nucleus activation, and restrained eating was negatively associated with insula activation. Our findings suggest that adolescent obesity is associated with disrupted tuning of the insula system towards interoceptive input. Copyright © 2015 Elsevier Ltd. All rights reserved.
Graham, Rebecca A.; Weems, Carl F.
2014-01-01
A substantial body of literature suggests that anxiety sensitivity is a risk factor for the development of anxiety problems and research has now begun to examine the links between parenting, parent anxiety sensitivity and their child’s anxiety sensitivity. However, the extant literature has provided mixed findings as to whether parent anxiety sensitivity is associated with child anxiety sensitivity, with some evidence suggesting that others factors may influence the association. Theoretically, specific parenting behaviors may be important to the development of child anxiety sensitivity and also in understanding the association between parent and child anxiety sensitivity. In this study, 191 families (n = 255 children and adolescents aged 6–17 and their parents) completed measures of child anxiety sensitivity (CASI) and parenting (APQ-C), and parents completed measures of their own anxiety sensitivity (ASI) and their parenting (APQ-P). Corporal punishment was associated with child anxiety sensitivity and the child’s report of their parent’s positive parenting behaviors moderated the association between parent and child anxiety sensitivity. The child’s gender was also found to moderate the association between parent and child anxiety sensitivity, such that there was a positive association between girls and parent anxiety sensitivity and a negative association in boys. The findings advance the understanding of child anxiety sensitivity by establishing a link with corporal punishment and by showing that the association between parent and child anxiety sensitivity may depend upon the parenting context and child’s gender. PMID:25301177
A subset of walnut allergic adults is sensitized to walnut 11S globulin Jug r 4.
Blankestijn, Mark A; den Hartog Jager, Constance F; Blom, W Marty; Otten, Henny G; de Jong, G Aard H; Gaspari, Marco; Houben, Geert F; Knulst, André C; Verhoeckx, Kitty C M
2018-06-15
The role of sensitization to commercially available allergens of English walnut (Juglans regia) Jug r 1, 2 and 3 in walnut allergy has been previously investigated in walnut allergic adults and was unable to explain allcases of walnut allergy. Identify recognized walnut allergens, other than the ones previously investigated (Jug r 1-3), in walnut allergic adults and determine the sensitization frequency and diagnostic value. Three different in-house walnut extracts were prepared and analysed on SDS-PAGE blots to identify allergenic walnut proteins. Immunoblots and immunoprecipitation, followed by LC-MS analysis, were performed to screen for, and confirm, IgE binding to walnut allergens in selected walnut allergic adults. In a cohort of 55 walnut challenged adults, including 33 allergic and 22 tolerant, sensitization to native and recombinant walnut allergen Jug r 4 was assessed using immunoblotting and immuno-line blot (EUROLINE), respectively. Screening of sera of eight walnut allergic adults identified Jug r 4 as an allergen in our population. In the total cohort of 55 subjects, five were positive for Jug r 4 on immunoblot and 10 on EUROLINE. All but one EUROLINE positive subject had a positive food challenge (sensitivity 27%, specificity 95%, PPV 90%, NPV 47%). All five subjects positive on immunoblot were also positive on EUROLINE. LC-MS analysis showed a lack of Jug r 4 in the ImmunoCAP extract. Co-sensitization to other 11S albumins (e.g. hazelnut Cor a 9) was common in Jug r 4 sensitized subjects, potentially due to cross-reactivity. Walnut 11S globulin Jug r 4 is a relevant minor allergen, recognized by 27% of walnut allergic adults. It has a high positive predictive value of 90% for walnut allergy. Specific IgE against Jug r 4 occurred mostly with concomitant sensitization to other walnut components, mainly Jug r 1. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
2017-01-30
workers function while on the job must be thoroughly evaluated by a competent healthcare provider and fitness for duty must be determined. Treatment...performance of job functions with or without accommodation. D. Prior to recommending an employee’s return to a safety sensitive position, the healthcare
NASA Astrophysics Data System (ADS)
Pushkarsky, Michael; Webber, Michael; Patel, C. Kumar N.
2005-03-01
We provide a general technique for evaluating the performance of an optical sensor for the detection of chemical warfare agents (CWAs) in realistic environments and present data from a simulation model based on a field deployed discretely tunable 13CO2 laser photoacoustic spectrometer (L-PAS). Results of our calculations show the sensor performance in terms of usable sensor sensitivity as a function of probability of false positives (PFP). The false positives arise from the presence of many other gases in the ambient air that could be interferents. Using the L-PAS as it exists today, we can achieve a detection threshold of about 4 ppb for the CWAs while maintaining a PFP of less than 1:106. Our simulation permits us to vary a number of parameters in the model to provide guidance for performance improvement. We find that by using a larger density of laser lines (such as those obtained through the use of tunable semiconductor lasers), improving the detector noise and maintaining the accuracy of laser frequency determination, optical detection schemes can make possible CWA sensors having sub-ppb detection capability with <1:108 PFP. We also describe the results of a preliminary experiment that verifies the results of the simulation model. Finally, we discuss the use of continuously tunable quantum cascade lasers in L-PAS for CWA and TIC detection.
NASA Astrophysics Data System (ADS)
Rijal, Nabin; Wiedenhover, Ingo; Baby, L. T.; Blackmon, J. C.; Rogachev, G.
2017-09-01
Astrophysically observed 7Li is 3 -4 times less than predicted amount by current models of Standard Big Bang Nucleosynthesis (SBBN). The nuclear reaction 7Be + d at energies relevant to SBBN, has been discussed as a possible means to destroy mass-7 nuclei. We investigated the 7Be + d and it's mirror nuclear reaction 7Li + d at SBBN energies using a radioactive 7Be and stable 7Li beam both in deuterium gas target inside ANASEN at Florida State University. ANASEN is an active target detector system which tracks the charged particles using a position sensitive proportional counter and 24-SX3 and 4-QQQ position sensitive Silicon detectors, all backed up by CsI detectors. ANASEN has wide angular coverage. The experiment measures a continuous excitation function by slowing down the beam in the target gas down to zero energy by using a single beam energy. Our set-up provides a high detection efficiency for all relevant reaction channels including (d , p) , (d , α) and/or direct breakup that can destroy mass-7 nuclei in contrast to previous measurements. The preliminary results of these experiments along with details of ANASEN detector will be presented. *ANASEN: Array for Nuclear Astrophysics and Structure with Exotic Nuclei. This work is supported by the US NSF MRI program, Grant No. PHY-0821308 and NSF Grant PHY-1401574.
Liu, Wanli; Li, Jianpei; Wu, Yixian; Xing, Shan; Lai, Yanzhen; Zhang, Ge
2018-04-15
Tumor-derived exosomes (TEXs) are extracellular vesicles that are continuously released into the blood by tumor cells and carry specific surface markers of the original tumor cells. Substantial evidence has implicated TEXs as attractive diagnostic markers for cancer. However, the detection of TEXs in blood at an early tumor stage is challenging due to their very low concentration. Here, we established a method called PLA-RPA-TMA assay that allows TEXs to be detected with high sensitivity and specificity. Based on two proximity ligation assay (PLA) probes that recognize a biomarker on a TEX, we generated a unique surrogate DNA signal for the specific biomarker, which was synchronously amplified twice by recombinase polymerase amplification (RPA) coupled with transcription-mediated amplification (TMA), and then the products of the RPA-TMA reaction were quantitatively detected using a gold nanoparticle-based colorimetric assay. We established proof-of-concept evidence for this approach using TEXs from nasopharyngeal carcinoma (NPC) cells, with a detection limit of 10 2 particles/mL, and reported the measurement of plasma Epstein-Barr virus latent membrane protein 1 (LPM1)-positive (LMP1 + , accuracy: 0.956) and epidermal growth factor receptor (EGFR)-positive (EGFR + , accuracy: 0.906) TEXs as potent early diagnostic biomarkers for NPC. Copyright © 2017 Elsevier B.V. All rights reserved.
Annular-Cross-Section CFE Chamber
NASA Technical Reports Server (NTRS)
Sharnez, Rizwan; Sammons, David W.
1994-01-01
Proposed continuous-flow-electrophoresis (CFE) chamber of annular cross section offers advantages over conventional CFE chamber, and wedge-cross-section chamber described in "Increasing Sensitivity in Continuous-Flow Electrophoresis" (MFS-26176). In comparison with wedge-shaped chamber, chamber of annular cross section virtually eliminates such wall effects as electro-osmosis and transverse gradients of velocity. Sensitivity enhanced by incorporating gradient maker and radial (collateral) flow.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 23 2014-07-01 2014-07-01 false How does the identification of ground water protection areas and other sensitive ground water areas affect me? 144.87 Section 144.87 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) UNDERGROUND INJECTION CONTROL PROGRAM Requirements for...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 24 2013-07-01 2013-07-01 false How does the identification of ground water protection areas and other sensitive ground water areas affect me? 144.87 Section 144.87 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) UNDERGROUND INJECTION CONTROL PROGRAM Requirements for...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 22 2010-07-01 2010-07-01 false How does the identification of ground water protection areas and other sensitive ground water areas affect me? 144.87 Section 144.87 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) UNDERGROUND INJECTION CONTROL PROGRAM Requirements for...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 23 2011-07-01 2011-07-01 false How does the identification of ground water protection areas and other sensitive ground water areas affect me? 144.87 Section 144.87 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) UNDERGROUND INJECTION CONTROL PROGRAM Requirements for...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 24 2012-07-01 2012-07-01 false How does the identification of ground water protection areas and other sensitive ground water areas affect me? 144.87 Section 144.87 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) UNDERGROUND INJECTION CONTROL PROGRAM Requirements for...
Projected Regime Shift in Arctic Cloud and Water Vapor Feedbacks
NASA Technical Reports Server (NTRS)
Chen, Yonghua; Miller, James R.; Francis, Jennifer; Russel, Gary L.
2011-01-01
The Arctic climate is changing faster than any other large-scale region on Earth. A variety of positive feedback mechanisms are responsible for the amplification, most of which are linked with changes in snow and ice cover, surface temperature (T(sub s)), atmospheric water vapor (WV), and cloud properties. As greenhouse gases continue to accumulate in the atmosphere, air temperature and water vapor content also increase, leading to a warmer surface and ice loss, which further enhance evaporation and WV. Many details of these interrelated feedbacks are poorly understood, yet are essential for understanding the pace and regional variations in future Arctic change. We use a global climate model (Goddard Institute for Space Studies, Atmosphere-Ocean Model) to examine several components of these feedbacks, how they vary by season, and how they are projected to change through the 21st century. One positive feedback begins with an increase in T(sub s) that produces an increase in WV, which in turn increases the downward longwave flux (DLF) and T(sub s), leading to further evaporation. Another associates the expected increases in cloud cover and optical thickness with increasing DLF and T(sub s). We examine the sensitivities between DLF and other climate variables in these feedbacks and find that they are strongest in the non-summer seasons, leading to the largest amplification in Ts during these months. Later in the 21st century, however, DLF becomes less sensitive to changes in WV and cloud optical thickness, as they cause the atmosphere to emit longwave radiation more nearly as a black body. This regime shift in sensitivity implies that the amplified pace of Arctic change relative to the northern hemisphere could relax in the future.
Evaluation of diagnostic cytology via endoscopic naso-pancreatic drainage for pancreatic tumor
Iwata, Tomoyuki; Kitamura, Katsuya; Yamamiya, Akira; Ishii, Yu; Sato, Yoshiki; Nomoto, Tomohiro; Ikegami, Akitoshi; Yoshida, Hitoshi
2014-01-01
AIM: To evaluate the usefulness of cytology of the pancreatic juice obtained via the endoscopic naso-pancreatic drainage tube (ENPD-C). METHODS: ENPD was performed in cases where a diagnosis could not be made other than by using endoscopic retrograde cholangiopancreatography and in cases of pancreatic neoplasms or cystic tumors, including intraductal papillary mucinous neoplasm (IPMN) suspected to have malignant potential. 35 patients (21 males and 14 females) underwent ENPD between January 2007 and June 2013. The pancreatic duct was imaged and the procedure continued in one of ENPD-C or ENPD-C plus brush cytology (ENPD-BC). We checked the cytology result and the final diagnosis. RESULTS: The mean patient age was 69 years (range, 48-86 years). ENPD-C was performed in 24 cases and ENPD-C plus brush cytology (ENPD-BC) in 11 cases. The ENPD tube was inserted for an average of 3.5 d. The final diagnosis was confirmed on the basis of the resected specimen in 18 cases and of follow-up findings at least 6 mo after ENPD in the 18 inoperable cases. Malignancy was diagnosed in 21 cases and 14 patients were diagnosed as having a benign condition. The ratios of class V/IV:III:II/I findings were 7:7:7 in malignant cases and 0:3:11 in benign cases. The sensitivity and specificity for all patients were 33.3% and 100%, respectively. The cytology-positive rate was 37.5% (6/16) for pancreatic cancer. For IPMN cases, the sensitivity and specificity were 33% and 100%, respectively. CONCLUSION: Sensitivity may be further increased by adding brush cytology. Although we can diagnosis cancer in cases of a positive result, the accuracy of ENPD-C remains unsatisfactory. PMID:25132920
Hunt, Kate; McCann, Claire; Gray, Cindy M; Mutrie, Nanette; Wyke, Sally
2013-01-01
To explore men's views of a pedometer-based walking program, part of a weight-management intervention delivered through Scottish Premier League football clubs, and the congruence or challenge this poses to masculine identities. Semistructured telephone interviews with a sample of participants in a gender-sensitized, group weight-management program. Interviewing continued until data saturation was reached (n = 29). All men were positive about the context, style of delivery, and content of the broader intervention. These things encouraged men to increase their physical activity (and adopt other behavioral changes) that they may not otherwise have found appealing. The success and acceptability of the walking program resided in three interrelated factors: (a) the utility of pedometers as a technology for motivation, self-monitoring and surveillance, and target setting; (b) the speed with which fitness was regained and weight reduced (enabling men to begin to do more desired forms of physical activity, and so regain visceral, experiential, and pragmatic masculine capital); and (c) bolstering their masculine identities through the receipt of the program in a valued, masculinised context. These data suggest that men will enthusiastically embrace a graduated walking program when the presentation is gender sensitive in context, content, and delivery. Pedometers were viewed as a valuable, reliable technological aid which motivated men and empowered them in self-monitoring of progress toward self-defined goals. Many men experienced the walking program as a means of regaining fitness, thereby enabling them to also regain valued masculine identities and activities, and a step toward regaining a more acceptable masculine body. PsycINFO Database Record (c) 2013 APA, all rights reserved.
Harrison, Tondi M
2013-01-01
Explore relationships among autonomic nervous system (ANS) function, child behavior, and maternal sensitivity in three-year-old children with surgically corrected transposition of the great arteries (TGA) and in children healthy at birth. Children surviving complex congenital heart defects are at risk for behavior problems. ANS function is associated with behavior and with maternal sensitivity. Child ANS function (heart rate variability) and maternal sensitivity (Parent-Child Early Relational Assessment) were measured during a challenging task. Mother completed the Child Behavior Checklist. Data were analyzed descriptively and graphically. Children with TGA had less responsive autonomic function and more behavior problems than healthy children. Autonomic function improved with more maternal sensitivity. Alterations in ANS function may continue years after surgical correction in children with TGA, potentially impacting behavioral regulation. Maternal sensitivity may be associated with ANS function in this population. Continued research on relationships among ANS function, child behavior, and maternal sensitivity is warranted. Copyright © 2013 Elsevier Inc. All rights reserved.
El Alaoui, Meddy; Soulère, Laurent; Noiriel, Alexandre; Queneau, Yves; Abousalham, Abdelkarim
2017-08-01
Lipases are essentially described as sn-1 and sn-3 regio-selective. Actually few methods are available to measure this lipase regio-selectivity, moreover they require chiral chromatography analysis or specific derivations which are discontinuous and time consuming. In this study we describe a new, convenient, sensitive and continuous spectrophotometric method to screen lipases regio-selectivity using synthetic triglycerides (TG) containing α-eleostearic acid (9Z, 11E, 13E-octadecatrienoic acid) either at the sn-1 position [1-α-eleostearoyl-2,3-octadecyl-sn-glycerol (sn-EOO)] or at the sn-3 position [1,2-octadecyl-3-α-eleostearoyl-sn-glycerol (sn-OOE)] and coated onto the wells of microtiter plates. A non-hydrolysable ether bond, with a non UV-absorbing alkyl chain, was introduced at the other sn positions to prevent acyl chain migration during TG synthesis or lipolysis. The synthesis of TG containing α-eleostearic acid was performed from S-glycidol in six steps to obtain sn-EOO and in five steps to sn-OOE. The α-eleostearic acid conjugated triene constitutes an intrinsic chromophore and, consequently, confers the strong UV absorption properties of this free fatty acid as well as of the TG harboring it. The lipase activity on coated sn-EOO or sn-OOE was measured by the increase in the absorbance at 272nm due to the transition of α-eleostearic acid from the adsorbed to the soluble state. Human and porcine pancreatic lipases, guinea pig pancreatic lipase related protein 2, Thermomyces lanuginosus lipase, Candida antarctica lipase A and Candida antarctica lipase B were all used to validate the assay. This continuous high-throughput screening method could determine directly without any processes after lipolysis the regio-selectivity of various lipases. Copyright © 2017 Elsevier B.V. All rights reserved.
Shuai, Binbin; Xia, Li; Liu, Deming
2012-11-05
We present and numerically characterize a liquid-core photonic crystal fiber based plasmonic sensor. The coupling properties and sensing performance are investigated by the finite element method. It is found that not only the plasmonic mode dispersion relation but also the fundamental mode dispersion relation is rather sensitive to the analyte refractive index (RI). The positive and negative RI sensitivity coexist in the proposed design. It features a positive RI sensitivity when the increment of the SPP mode effective index is larger than that of the fundamental mode, but the sensor shows a negative RI sensitivity once the increment of the fundamental mode gets larger. A maximum negative RI sensitivity of -5500nm/RIU (Refractive Index Unit) is achieved in the sensing range of 1.50-1.53. The effects of the structural parameters on the plasmonic excitations are also studied, with a view of tuning and optimizing the resonant spectrum.
Standing Vs Supine; Does it Matter in Cough Stress Testing?
Patnam, Radhika; Edenfield, Autumn L; Swift, Steven E
The aim of this study was to compare the sensitivity of cough stress test in the standing versus supine position in the evaluation of incontinent females. We performed a prospective observational study of women with the chief complaint of urinary incontinence (UI) undergoing a provocative cough stress test (CST). Subjects underwent both a standing and a supine CST. Testing order was randomized via block randomization. Cough stress test was performed in a standard method via backfill of 200 mL or until the subject described strong urge. The subjects were asked to cough, and the physician documented urine leakage by direct observation. The gold standard for stress UI diagnosis was a positive CST in either position. Sixty subjects were enrolled, 38 (63%) tested positive on any CST, with 38 (63%) positive on standing compared with 29 (28%) positive on supine testing. Nine women (15%) had positive standing and negative supine testing. No subjects had negative standing with positive supine testing. There were no significant differences in positive tests between the 2 randomized groups (standing first and supine second vs. supine first and standing second). When compared with the gold standard of any positive provocative stress test, the supine CST has a sensitivity of 76%, whereas the standing CST has a sensitivity of 100%. The standing CST is more sensitive than the supine CST and should be performed in any patient with a complaint of UI and negative supine CST. The order of testing either supine or standing first does not affect the results.
Figure-ground processing during fixational saccades in V1: indication for higher-order stability.
Gilad, Ariel; Pesoa, Yair; Ayzenshtat, Inbal; Slovin, Hamutal
2014-02-26
In a typical visual scene we continuously perceive a "figure" that is segregated from the surrounding "background" despite ongoing microsaccades and small saccades that are performed when attempting fixation (fixational saccades [FSs]). Previously reported neuronal correlates of figure-ground (FG) segregation in the primary visual cortex (V1) showed enhanced activity in the "figure" along with suppressed activity in the noisy "background." However, it is unknown how this FG modulation in V1 is affected by FSs. To investigate this question, we trained two monkeys to detect a contour embedded in a noisy background while simultaneously imaging V1 using voltage-sensitive dyes. During stimulus presentation, the monkeys typically performed 1-3 FSs, which displaced the contour over the retina. Using eye position and a 2D analytical model to map the stimulus onto V1, we were able to compute FG modulation before and after each FS. On the spatial cortical scale, we found that, after each FS, FG modulation follows the stimulus retinal displacement and "hops" within the V1 retinotopic map, suggesting visual instability. On the temporal scale, FG modulation is initiated in the new retinotopic position before it disappeared from the old retinotopic position. Moreover, the FG modulation developed faster after an FS, compared with after stimulus onset, which may contribute to visual stability of FG segregation, along the timeline of stimulus presentation. Therefore, despite spatial discontinuity of FG modulation in V1, the higher-order stability of FG modulation along time may enable our stable and continuous perception.
Kortz, Teresa Bleakly; Herzel, Benjamin; Marseille, Elliot; Kahn, James G
2017-01-01
Objectives Pneumonia is the largest infectious cause of death in children under 5 years globally, and limited resource settings bear an overwhelming proportion of this disease burden. Bubble continuous positive airway pressure (bCPAP), an accepted supportive therapy, is often thought of as cost-prohibitive in these settings. We hypothesise that bCPAP is a cost-effective intervention in a limited resource setting and this study aims to determine the cost-effectiveness of bCPAP, using Malawi as an example. Design Cost-effectiveness analysis. Setting District and central hospitals in Malawi. Participants Children aged 1 month–5 years with severe pneumonia, as defined by WHO criteria. Interventions Using a decision tree analysis, we compared standard of care (including low-flow oxygen and antibiotics) to standard of care plus bCPAP. Primary and secondary outcome measures For each treatment arm, we determined the costs, clinical outcomes and averted disability-adjusted life years (DALYs). We assigned input values from a review of the literature, including applicable clinical trials, and calculated an incremental cost-effectiveness ratio (ICER). Results In the base case analysis, the cost of bCPAP per patient was $15 per day and $41 per hospitalisation, with an incremental net cost of $64 per pneumonia episode. bCPAP averts 5.0 DALYs per child treated, with an ICER of $12.88 per DALY averted compared with standard of care. In one-way sensitivity analyses, the most influential uncertainties were case fatality rates (ICER range $9–32 per DALY averted). In a multi-way sensitivity analysis, the median ICER was $12.97 per DALY averted (90% CI, $12.77 to $12.99). Conclusion bCPAP is a cost-effective intervention for severe paediatric pneumonia in Malawi. These results may be used to inform policy decisions, including support for widespread use of bCPAP in similar settings. PMID:28698327
Singhi, Aatur D; Zeh, Herbert J; Brand, Randall E; Nikiforova, Marina N; Chennat, Jennifer S; Fasanella, Kenneth E; Khalid, Asif; Papachristou, Georgios I; Slivka, Adam; Hogg, Melissa; Lee, Kenneth K; Tsung, Allan; Zureikat, Amer H; McGrath, Kevin
2016-06-01
The American Gastroenterological Association (AGA) recently reported evidence-based guidelines for the management of asymptomatic neoplastic pancreatic cysts. These guidelines advocate a higher threshold for surgical resection than prior guidelines and imaging surveillance for a considerable number of patients with pancreatic cysts. The aims of this study were to assess the accuracy of the AGA guidelines in detecting advanced neoplasia and present an alternative approach to pancreatic cysts. The study population consisted of 225 patients who underwent EUS-guided FNA for pancreatic cysts between January 2014 and May 2015. For each patient, clinical findings, EUS features, cytopathology results, carcinoembryonic antigen analysis, and molecular testing of pancreatic cyst fluid were reviewed. Molecular testing included the assessment of hotspot mutations and deletions for KRAS, GNAS, VHL, TP53, PIK3CA, and PTEN. Diagnostic pathology results were available for 41 patients (18%), with 13 (6%) harboring advanced neoplasia. Among these cases, the AGA guidelines identified advanced neoplasia with 62% sensitivity, 79% specificity, 57% positive predictive value, and 82% negative predictive value. Moreover, the AGA guidelines missed 45% of intraductal papillary mucinous neoplasms with adenocarcinoma or high-grade dysplasia. For cases without confirmatory pathology, 27 of 184 patients (15%) with serous cystadenomas (SCAs) based on EUS findings and/or VHL alterations would continue magnetic resonance imaging (MRI) surveillance. In comparison, a novel algorithmic pathway using molecular testing of pancreatic cyst fluid detected advanced neoplasias with 100% sensitivity, 90% specificity, 79% positive predictive value, and 100% negative predictive value. The AGA guidelines were inaccurate in detecting pancreatic cysts with advanced neoplasia. Furthermore, because the AGA guidelines manage all neoplastic cysts similarly, patients with SCAs will continue to undergo unnecessary MRI surveillance. The results of an alternative approach with integrative molecular testing are encouraging but require further validation. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Chang, Ya-Shu; Yee, Brendon J; Hoyos, Camilla M; Wong, Keith K; Sullivan, David R; Grunstein, Ronald R; Phillips, Craig L
2017-11-01
Untreated obstructive sleep apnoea (OSA) is associated with increased risk of coronary artery disease (CAD) and heart failure. High-sensitivity cardiac troponin (hs Trop-T) and B-type natriuretic peptide (NT-pro-BNP) are sensitive biomarkers for myocardial injury and heart failure respectively. No randomised controlled trials have examined the treatment effect of continuous positive airway pressure (CPAP) in patients with OSA on these biomarkers. Patients >21 years old with apnoea-hypopnoea index (AHI) ≥25/h by overnight polysomnography were recruited. Main exclusion criteria were previous CPAP use and any significant comorbidities including CAD and heart failure. Eligible subjects were randomised to receive CPAP or sham CPAP for eight weeks each in a crossover design with a wash out period of one month between the treatments. Blood samples were collected at 8pm, 3am, and 8am during sleep studies conducted at the end of each eight-week treatment period. Of the 37 patients who were randomised, 28 patients had stored frozen samples available for analysis. In comparison to sham treatment, CPAP significantly lowered the NT-pro-BNP level by 0.91 pmol/L (p = 0.0002). The reduction of 0.235 ng/L in hs Trop-T on CPAP therapy was not statistically significant (p = 0.052). There were no overnight changes, across the three time points, in either biomarker with either treatment. Our study confirms CPAP therapy in patients with moderate-severe OSA reduces NT-pro-BNP, but we did not confirm a significant effect on hs Trop-T. Future larger studies of longer duration incorporating biomarkers and cardiac functional measures are needed to better establish the benefit of OSA treatment. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.
Accuracy evaluation of a new real-time continuous glucose monitoring algorithm in hypoglycemia.
Mahmoudi, Zeinab; Jensen, Morten Hasselstrøm; Dencker Johansen, Mette; Christensen, Toke Folke; Tarnow, Lise; Christiansen, Jens Sandahl; Hejlesen, Ole
2014-10-01
The purpose of this study was to evaluate the performance of a new continuous glucose monitoring (CGM) calibration algorithm and to compare it with the Guardian(®) REAL-Time (RT) (Medtronic Diabetes, Northridge, CA) calibration algorithm in hypoglycemia. CGM data were obtained from 10 type 1 diabetes patients undergoing insulin-induced hypoglycemia. Data were obtained in two separate sessions using the Guardian RT CGM device. Data from the same CGM sensor were calibrated by two different algorithms: the Guardian RT algorithm and a new calibration algorithm. The accuracy of the two algorithms was compared using four performance metrics. The median (mean) of absolute relative deviation in the whole range of plasma glucose was 20.2% (32.1%) for the Guardian RT calibration and 17.4% (25.9%) for the new calibration algorithm. The mean (SD) sample-based sensitivity for the hypoglycemic threshold of 70 mg/dL was 31% (33%) for the Guardian RT algorithm and 70% (33%) for the new algorithm. The mean (SD) sample-based specificity at the same hypoglycemic threshold was 95% (8%) for the Guardian RT algorithm and 90% (16%) for the new calibration algorithm. The sensitivity of the event-based hypoglycemia detection for the hypoglycemic threshold of 70 mg/dL was 61% for the Guardian RT calibration and 89% for the new calibration algorithm. Application of the new calibration caused one false-positive instance for the event-based hypoglycemia detection, whereas the Guardian RT caused no false-positive instances. The overestimation of plasma glucose by CGM was corrected from 33.2 mg/dL in the Guardian RT algorithm to 21.9 mg/dL in the new calibration algorithm. The results suggest that the new algorithm may reduce the inaccuracy of Guardian RT CGM system within the hypoglycemic range; however, data from a larger number of patients are required to compare the clinical reliability of the two algorithms.
Kortz, Teresa Bleakly; Herzel, Benjamin; Marseille, Elliot; Kahn, James G
2017-07-10
Pneumonia is the largest infectious cause of death in children under 5 years globally, and limited resource settings bear an overwhelming proportion of this disease burden. Bubble continuous positive airway pressure (bCPAP), an accepted supportive therapy, is often thought of as cost-prohibitive in these settings. We hypothesise that bCPAP is a cost-effective intervention in a limited resource setting and this study aims to determine the cost-effectiveness of bCPAP, using Malawi as an example. Cost-effectiveness analysis. District and central hospitals in Malawi. Children aged 1 month-5 years with severe pneumonia, as defined by WHO criteria. Using a decision tree analysis, we compared standard of care (including low-flow oxygen and antibiotics) to standard of care plus bCPAP. For each treatment arm, we determined the costs, clinical outcomes and averted disability-adjusted life years (DALYs). We assigned input values from a review of the literature, including applicable clinical trials, and calculated an incremental cost-effectiveness ratio (ICER). In the base case analysis, the cost of bCPAP per patient was $15 per day and $41 per hospitalisation, with an incremental net cost of $64 per pneumonia episode. bCPAP averts 5.0 DALYs per child treated, with an ICER of $12.88 per DALY averted compared with standard of care. In one-way sensitivity analyses, the most influential uncertainties were case fatality rates (ICER range $9-32 per DALY averted). In a multi-way sensitivity analysis, the median ICER was $12.97 per DALY averted (90% CI, $12.77 to $12.99). bCPAP is a cost-effective intervention for severe paediatric pneumonia in Malawi. These results may be used to inform policy decisions, including support for widespread use of bCPAP in similar settings. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Colley, Daniel G; Andros, Tamara S; Campbell, Carl H
2017-03-22
Mapping and diagnosis of infections by the three major schistosome species (Schistosoma haematobium, S. mansoni and S. japonicum) has been done with assays that are known to be specific but increasingly insensitive as prevalence declines or in areas with already low prevalence of infection. This becomes a true challenge to achieving the goal of elimination of schistosomiasis because the multiplicative portion of the life-cycle of schistosomes, in the snail vector, favors continued transmission as long as even a few people maintain low numbers of worms that pass eggs in their excreta. New mapping tools based on detection of worm antigens (circulating cathodic antigen - CCA; circulating anodic antigen - CAA) in urine of those infected are highly sensitive and the CAA assay is reported to be highly specific. Using these tools in areas of low prevalence of all three of these species of schistosomes has demonstrated that more people harbor adult worms than are regularly excreting eggs at a level detectable by the usual stool assay (Kato-Katz) or by urine filtration. In very low prevalence areas this is sometimes 6- to10-fold more. Faced with what appears to be a sizable population of "egg-negative/worm-positive schistosomiasis" especially in areas of very low prevalence, national NTD programs are confounded about what guidelines and strategies they should enact if they are to proceed toward a goal of elimination. There is a critical need for continued evaluation of the assays involved and to understand the contribution of this "egg-negative/worm-positive schistosomiasis" condition to both individual morbidity and community transmission. There is also a critical need for new guidelines based on the use of these more sensitive assays for those national NTD programs that wish to move forward to strategies designed for elimination.
Dunthorn, Jason; Dyer, Robert M; Neerchal, Nagaraj K; McHenry, Jonathan S; Rajkondawar, Parimal G; Steingraber, Gary; Tasch, Uri
2015-11-01
Lameness remains a significant cause of production losses, a growing welfare concern and may be a greater economic burden than clinical mastitis . A growing need for accurate, continuous automated detection systems continues because US prevalence of lameness is 12.5% while individual herds may experience prevalence's of 27.8-50.8%. To that end the first force-plate system restricted to the vertical dimension identified lame cows with 85% specificity and 52% sensitivity. These results lead to the hypothesis that addition of transverse and longitudinal dimensions could improve sensitivity of lameness detection. To address the hypothesis we upgraded the original force plate system to measure ground reaction forces (GRFs) across three directions. GRFs and locomotion scores were generated from randomly selected cows and logistic regression was used to develop a model that characterised relationships of locomotion scores to the GRFs. This preliminary study showed 76 variables across 3 dimensions produced a model with greater than 90% sensitivity, specificity, and area under the receiver operating curve (AUC). The result was a marked improvement on the 52% sensitivity, and 85% specificity previously observed with the 1 dimensional model or the 45% sensitivities reported with visual observations. Validation of model accuracy continues with the goal to finalise accurate automated methods of lameness detection.
NBS work on neutron resonance radiography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schrack, R.A.
1987-01-01
NBS has been engaged in a wide-ranging program in Neutron Resonance Radiography utilizing both one- and two-dimensional position-sensitive neutron detectors. The ability to perform a position-sensitive assay of up to 16 isotopes in a complex matrix has been demonstrated for a wide variety of sample types, including those with high gamma activity. A major part of the program has been the development and application of the microchannel-plate-based position-sensitive neutron detector. This detector system has high resolution and sensitivity, together with adequate speed of response to be used with neutron time-of-flight techniques. This system has demonstrated the ability to simultaneously imagemore » three isotopes in a sample with no interference.« less
Li, James J
2018-03-20
Atypical reward processing, including abnormal reward responsivity and sensitivity to punishment, has long been implicated in the etiology of ADHD. However, little is known about how these facets of behavior interact with positive (e.g., warmth, praise) and negative (e.g., hostility, harsh discipline) parenting behavior in the early expression of ADHD symptoms in young children. Understanding the interplay between children's reward processing and parenting may be crucial for identifying specific treatment targets in psychosocial interventions for ADHD, especially given that not all children benefit from contingency-based treatments (e.g., parent management training). The study consisted of a sample of kindergarten children (N = 201, 55% male) and their parents, who completed questionnaires about their parenting practices, their child's behaviors and participated in an observed parent-child play task in the laboratory. Children's reward responsivity and sensitivity to punishment were positively associated with child ADHD symptoms. However, children with high reward responsivity had more symptoms of ADHD but only under conditions of low negative parenting (self-reported and observed) and high self-reported positive parenting, compared to children with low reward responsivity. Children with high sensitivity to punishment had more ADHD symptoms relative to children with low sensitivity to punishment, but only under conditions in which observed praise was infrequent. Results provide evidence that individual differences in sensitivity to reward/punishment may be an important of marker of risk for ADHD, but also highlights how children's responses to positive and negative parenting behavior may vary by children's sensitivities. Clinical and treatment implications are discussed.
Evaluation of diagnostic serological results in cases of suspected primary syphilis infection.
Gratzer, Beau; Pohl, Daniel; Hotton, Anna L
2014-05-01
Reverse sequence screening for syphilis, in which an automatable treponemal assay (enzyme immunoassay [EIA]/chemiluminescence assay [CIA]) is performed first and followed by a nontreponemal test for reactive specimens, has been used increasingly in the United States. The EIA is objective, efficient, and believed to be more sensitive than the rapid plasma reagin (RPR) because treponemal antibodies appear before nontreponemal antibodies. We sought to compare the sensitivity of a commonly used EIA, the Trep-Sure EIA (TS-EIA), to the RPR in cases of suspected primary syphilis infection in our clinic. A retrospective medical record review of patients with sexually transmitted infection clinic visits from January 2009 to December 2011 was conducted, and 52 patients met the following inclusion criteria: suspected primary syphilis symptoms, at least 1 positive syphilis test result at visit, and no history of syphilis. Sensitivity analyses compared the TS-EIA and RPR, using the reference standard of concordantly positive/reactive TS-EIA/RPR or positive fluorescent treponemal antibody absorption test (FTA-ABS) result. We considered equivocal TS-EIA results to be positive for sensitivity calculations because such results typically reflex to additional testing and therefore may still result in identifying new infections. Twenty-eight (53.8%) of the 52 patients had a positive or equivocal TS-EIA. Twenty-five (89.3%) of those were RPR reactive; the remaining 3 (10.7%) were RPR nonreactive, FTA-ABS positive. Forty patients (76.9%) had a positive RPR, including 15 patients (37.5%) with negative TS-EIA results; all 15 were FTA-ABS positive. Nine additional patients were TS-EIA negative and RPR nonreactive but had a positive FTA-ABS result. The RPR was significantly more sensitive than the EIA (76.9% vs. 53.8%, P = 0.005). Trep-Sure EIA positivity was also significantly associated with higher median RPR titer (P = 0.011). Use of the TS-EIA may result in underdetection of primary syphilis compared with the RPR. Further evaluation of the sensitivity of the TS-EIA in high-morbidity settings is warranted before the adoption of reverse sequence screening algorithms.
Highly variable sensitivity of five binding and two bio-assays for TSH-receptor antibodies.
Diana, T; Wüster, C; Kanitz, M; Kahaly, G J
2016-10-01
TSH-receptor (TSHR) antibodies (Ab) can be measured with binding or bio-assays. Sensitivity and specificity of five binding and two bio-assays were compared. TSHR-blocking (TBAb) and TSHR-stimulating (TSAb) Ab were measured with reporter bio-assays. Blocking activity was defined as percent inhibition of luciferase expression relative to induction with bTSH alone. TSAb was reported as percentage of specimen-to-reference ratio (SRR%). TSHR-binding inhibitory immunoglobulins (TBII) were measured with Kronus, Dynex, Kryptor, Cobas, and Immulite. Sixty patients with Graves' disease (GD), 20 with Hashimoto's thyroiditis (HT), and 20 healthy controls (C) were included. C tested negative in all assays (specificity 100 %) while all 60 hyperthyroid GD patients tested positive in the TSAb bio-assay (sensitivity 100 %). Among these 60 GD patients, 20 had low TSAb positivity (SRR% 140-279), but were TBII positive in only 20 (100 %), 7 (35 %), 9 (45 %), 11 (55 %), and 18 (90 %) using the Kronus, Dynex, Kryptor, Cobas, and Immulite, respectively. In 20 moderate TSAb-positive (SRR% 280-420) patients, TBII tested positive in 20 (100 %), 14 (70 %), 13 (65 %), 16 (80 %), and 19 (95 %), respectively. The high (SRR% > 420) TSAb-positive patients were all TBII positive. All 20 hypothyroid HT patients tested TBAb positive (sensitivity 100 %) in the bio-assay while they tested TBII positive in 20 (100 %), 18 (90 %), 20, 20, and 18, respectively. Results obtained with two luminometers correlated for TSAb positive (r = 0.99, p < 0.001), TBAb positive (r = 0.88, p < 0.001), and C (r = 0.86, p < 0.001). None of the binding assays differentiated between TSAb and TBAb. Sensitivity is highly variable between binding and bio-assays for TSHR-Abs.
Utility and limitations of a peptide reactivity assay to predict fragrance allergens in vitro.
Natsch, A; Gfeller, H; Rothaupt, M; Ellis, G
2007-10-01
A key step in the skin sensitization process is the formation of a covalent adduct between the skin sensitizer and endogenous proteins and/or peptides in the skin. A published peptide depletion assay was used to relate the in vitro reactivity of fragrance molecules to LLNA data. Using the classical assay, 22 of 28 tested moderate to strong sensitizers were positive. The prediction of weak sensitizers proved to be more difficult with only 50% of weak sensitizers giving a positive response, but for some compounds this could also be due to false-positive results from the LLNA. LC-MS analysis yielded the expected mass of the peptide adducts in several cases, whereas in other cases putative oxidation reactions led to adducts of unexpected molecular weight. Several moderately sensitizing aldehydes were correctly predicted by the depletion assay, but no adducts were found and the depletion appears to be due to an oxidation of the parent peptide catalyzed by the test compound. Finally, alternative test peptides derived from a physiological reactive protein with enhanced sensitivity for weak Michael acceptors were found, further increasing the sensitivity of the assay.
Drama-induced affect and pain sensitivity.
Zillmann, D; de Wied, M; King-Jablonski, C; Jenzowsky, S
1996-01-01
This study was conducted to examine the pain-ameliorating and pain-sensitizing effects of exposure to emotionally engaging drama. Specifically, the consequences for pain sensitivity of exposure to dramatic expositions differing in both excitatory and hedonic qualities were determined. Hedonically negative, neutral, and positive affective states were induced in male respondents by exposure to excerpts from cinematic drama. Pain sensitivity was assessed by the cuff-pressure procedure before and after exposure and by the cold pressor test after exposure only. When compared against the control condition, pain sensitivity diminished under conditions of hedonically positive affect. An inverse effect was suggested for hedonically negative conditions, but proved tentative and statistically unreliable. The findings are consistent with earlier demonstrations of mood effects on pain sensitivity. Unlike inconclusive earlier findings concerning the magnitude of directional effects, however, they suggest an asymmetry that emphasizes the pain-ameliorating effect of positive affects while lending little, if any, support to the proposal of a pain-sensitizing effect of negative affects. The investigation did not accomplish the intended creation of conditions necessary to test the proposal that heightened sympathetic activity diminishes pain sensitivity. The utility of a rigorous determination of this hypothesized relationship is emphasized, and procedures for a viable test of the proposal are suggested.
Complement activation and liver impairment in trichloroethylene-sensitized BALB/c mice.
Zhang, Jiaxiang; Zha, Wansheng; Wang, Feng; Jiang, Tao; Xu, Shuhai; Yu, Junfeng; Zhou, Chengfan; Shen, Tong; Wu, Changhao; Zhu, Qixing
2013-01-01
Our recent studies have shown that trichloroethylene (TCE) was able to induce multisystem injuries in the form of occupational medicamentosa-like dermatitis, including skin, kidney, and liver damages. However, the role of complement activation in the immune-mediated liver injury is not known. This study examined the role of complement activation in the liver injury in a mouse model of TCE-induced sensitization. Treatment of female BALB/c mice with TCE under specific dosing protocols resulted in skin inflammation and sensitization. Skin edema and erythema occurred in TCE-sensitized groups. Trichloroethylene sensitization produced liver histopathological lesions, increased serum alanine aminotransferase, aspartate transaminase activities, and the relative liver weight. The concentrations of serum complement components C3a-desArg, C5a-desArg, and C5b-9 were significantly increased in 24-hour, 48-hour, and 72-hour sensitization-positive groups treated with TCE and peaked in the 72-hour sensitization-positive group. Depositions of C3a, C5a, and C5b-9 into the liver tissue were also revealed by immunohistochemistry. Immunofluorescence further verified high C5b-9 expression in 24-hour, 48-hour, and 72-hour sensitization-positive groups in response to TCE treatment. Reverse transcription-polymerase chain reaction detected C3 messenger RNA expression in the liver, and this was significantly increased in 24-hour and 48-hour sensitization-positive groups with a transient reduction at 72 hours. These results provide the first experimental evidence that complement activation may play a key role in the generation and progression of immune-mediated hepatic injury by exposure to TCE.
Gallenga, P E; Neri, Giampiero; D'Anastasio, Ruggero; Pettorrossi, Vito Enrico; Alfieri, Emilio; Capasso, Luigi
2012-06-01
Charged by the Pope Julius II for painting the Cappella Sistina in Rome (between 1508 and 1512), Michelangelo worked in an elevated scaffolding, in an anomalous position with dyes (including poisoning lead salts) and solvents (such as toxic turpentine) dripping on his face and continuously inhaling, in a dim environment illuminated only with oil lamps and candles, as he described himself and sketched in a sonet addressed to Giovanni da Pistoia. In 1510 he began suffering from eye disease: the main symptom was the necessity to elevate the document he was reading up to the level of his eyes. This defect disappeared few months after he finished painting his masterpiece. We hypothesize that the Michelangelo's eyes disease was a form of acquired and transitory nystagmus induced by the many hours he spent in up gaze, with a skew deviation, a form of ocular tilt reaction resulting from the impairment of spatial sensitivity (inversion illusion) due to the persistence of the artist's head in a horizontal position, looking upward. Copyright © 2012 Elsevier Ltd. All rights reserved.
Adaptive [theta]-methods for pricing American options
NASA Astrophysics Data System (ADS)
Khaliq, Abdul Q. M.; Voss, David A.; Kazmi, Kamran
2008-12-01
We develop adaptive [theta]-methods for solving the Black-Scholes PDE for American options. By adding a small, continuous term, the Black-Scholes PDE becomes an advection-diffusion-reaction equation on a fixed spatial domain. Standard implementation of [theta]-methods would require a Newton-type iterative procedure at each time step thereby increasing the computational complexity of the methods. Our linearly implicit approach avoids such complications. We establish a general framework under which [theta]-methods satisfy a discrete version of the positivity constraint characteristic of American options, and numerically demonstrate the sensitivity of the constraint. The positivity results are established for the single-asset and independent two-asset models. In addition, we have incorporated and analyzed an adaptive time-step control strategy to increase the computational efficiency. Numerical experiments are presented for one- and two-asset American options, using adaptive exponential splitting for two-asset problems. The approach is compared with an iterative solution of the two-asset problem in terms of computational efficiency.
Rapid diagnostic methods for influenza virus in clinical specimens - A comparative study
NASA Technical Reports Server (NTRS)
Evans, A. S.; Olson, B.
1982-01-01
A comparison of five rapid viral diagnostic techniques for identifying influenza virus in nasopharyngeal aspirates has been made on patients with influenza-like illnesses. Initial results with immune electron microscopy were positive in only one of 11 specimens from which virus was isolated and further work abandoned. Four other rapid tests were carried out on 39 specimens from which influenza virus had been isolated in tissue culture in 28. Of these 28 specimens yielding virus, 24 (85.7 percent) were positive by an indirect fluorescent antibody test (IFAT) on nasopharyngeal cells, 18 (64.3 percent) by enzyme-linked immunosorbent assay (ELISA), 19 (67.8 percent) by enzyme-linked fluorescent assay (ELFA), and 26 (92.8 percent) by a rapid tissue culture amplification method (TCA) in a continuous Rhesus monkey kidney line (LLC-MK2) with identification of virus by fluorescent antibody. In terms of sensitivity, simplicity, and rapidity, a combination of the IFAT and TCA methods seems to be very useful.
Toli, Theodora; Sourtzi, Panagiota; Tsoumakas, Konstantinos; Kalokerinou-Anagnostopoulou, Athena
2013-05-01
School nurses have the ability to enhance the knowledge and tolerance of an entire community and to form more positive and sensitized attitudes to future adults. The aim of this study was to investigate the relationship between the knowledge and attitudes of nurses and the frequency of accidents caused by epilepsy in Greek schools. Our sample consisted of 306 school nurses from all over the country. It was observed that the knowledge of school nurses on epilepsy was quite high, although there were specific aspects that raise concerns on their preparedness to respond to seizure-related emergencies, while their attitudes, although positive, still need improvement. Accidents caused by epilepsy were reported by half of the nurses, and prevention was considered of major importance. Therefore, organized continuous education programs and clear guidelines by the responsible authorities would help school nurses provide better services to students with epilepsy. Copyright © 2013 Elsevier Inc. All rights reserved.
Hanaya, Junko; Nakamura, Yasuko; Nejima, Ryouhei; Miyata, Kazunori; Mera, Kentarou; Ohguro, Hiroshi; Yamamoto, Shuichi
2011-06-01
We report a case of melanoma-associated retinopathy (MAR) associated with positive auto-antibodies against retinal bipolar cells, which has been rarely reported in Japan. A 33 year-old woman noticed shimmering vision, photopsias, blurred vision, and night blindness OS in April 2009, and visited Kagoshima Miyata Eye Clinic in May 2009. She had been continuously treated for malignant melanoma on her left finger since 2007. At her initial visit, the corrected visual acuity was 1.5 OD and 1.2 OS, and slit-lamp examination revealed clear ocular media OU. Funduscopic examination showed normal appearance of the retina OU, except for a mild narrowing of the retinal arteries OS. Humphrey field analyzer revealed a reduction of retinal sensitivity within the central 30 degrees OS. The maximum left eye response of electroretinogram (ERG) showed a negative waveform. The immuno-cytochemical test revealed antibodies against retinal bipolar cells, which confirmed the diagnosis of MAR. Characteristic subjective symptoms, Humphrey field analyzer and ERG are useful for the diagnosis of MAR.
Reflective terahertz (THz) imaging: system calibration using hydration phantoms
NASA Astrophysics Data System (ADS)
Bajwa, Neha; Garritano, James; Lee, Yoon Kyung; Tewari, Priyamvada; Sung, Shijun; Maccabi, Ashkan; Nowroozi, Bryan; Babakhanian, Meghedi; Sanghvi, Sajan; Singh, Rahul; Grundfest, Warren; Taylor, Zachary
2013-02-01
Terahertz (THz) hydration sensing continues to gain traction in the medical imaging community due to its unparalleled sensitivity to tissue water content. Rapid and accurate detection of fluid shifts following induction of thermal skin burns as well as remote corneal hydration sensing have been previously demonstrated in vivo using reflective, pulsed THz imaging. The hydration contrast sensing capabilities of this technology were recently confirmed in a parallel 7 Tesla Magnetic Resonance (MR) imaging study, in which burn areas are associated with increases in local mobile water content. Successful clinical translation of THz sensing, however, still requires quantitative assessments of system performance measurements, specifically hydration concentration sensitivity, with tissue substitutes. This research aims to calibrate the sensitivity of a novel, reflective THz system to tissue water content through the use of hydration phantoms for quantitative comparisons of THz hydration imagery.Gelatin phantoms were identified as an appropriate tissue-mimicking model for reflective THz applications, and gel composition, comprising mixtures of water and protein, was varied between 83% to 95% hydration, a physiologically relevant range. A comparison of four series of gelatin phantom studies demonstrated a positive linear relationship between THz reflectivity and water concentration, with statistically significant hydration sensitivities (p < .01) ranging between 0.0209 - 0.038% (reflectivity: %hydration). The THz-phantom interaction is simulated with a three-layer model using the Transfer Matrix Method with agreement in hydration trends. Having demonstrated the ability to accurately and noninvasively measure water content in tissue equivalent targets with high sensitivity, reflective THz imaging is explored as a potential tool for early detection and intervention of corneal pathologies.
Vlemincx, Elke; Van Diest, Ilse; Van den Bergh, Omer
2016-10-15
Both animal and human research have revealed important associations between sighs and relief. Previously we argued to conceive of sighs as resetters which temporarily induce relief. The present study aimed to investigate the psychological and physiological relief effect of sighs by instructed deep breaths and spontaneous sighs compared to a control breathing maneuver. Participants completed three blocks of 40 trials during which uncertainty cues were followed by either safety cues followed by a positive picture, or danger cues followed by a negative picture. One block was presented without breathing instructions, two subsequent blocks with breathing instructions. During the presentation of the safety and danger cues, an instruction was given to either 'take a deep breath' or 'postpone the next inhalation for 2 s (breath hold). Continuously, participants rated relief and Frontalis electromyography was recorded. Trait anxiety sensitivity was assessed by the Anxiety Sensitivity Index. Self-reported relief and physiological tension were compared 5s before and after instructed deep breaths and breath holds, and before and after spontaneous deep breaths and breath holds in the respective blocks. Results show that self-reported relief following an instructed deep breath was higher than before. Physiological tension decreased following a spontaneous sigh in high anxiety sensitive persons and following a spontaneous breath hold in low anxiety sensitive persons. These results are the first to show that a deep breath relieves and, in anxiety sensitive persons, reduces physiological tension. These findings support the hypothesis that sighs are psychological and physiological resetters. Copyright © 2016 Elsevier Inc. All rights reserved.
Suk, Min Hyun; Oh, Won Oak; Im, Yeo Jin; Cho, Hun Ha
2015-09-01
This study examined the mediating effect of school nurses' self efficacy, which is one of the significant cognitive factors influencing cultural sensitivity, on the mutual relationships between multicultural attitude and cultural sensitivity in Korean elementary schools. A cross-sectional descriptive survey design was used. Participants were 157 school nurses in elementary schools located in Gyeonggi-do, South Korea. The survey instruments included Teacher Multicultural Attitude Survey, Teacher Efficacy Scale, and Multicultural Sensitivity Scale. Data were analyzed using three regression equations to test the mediation model. The mean score of the school nurses' cultural sensitivity was relatively low. A positive correlation among multicultural attitude, self efficacy, and cultural sensitivity was noted. Self efficacy of school nurses showed a significant mediating effect on the relationships between multicultural attitude and cultural sensitivity. Given the meaningful influence of positive multicultural attitude on cultural sensitivity and significant mediator effect of self efficacy as a school nurse between the two variables, the strategies to cultivate a positive multicultural attitude and enhance school nurses' self efficacy in their unique role should be considered in a training program. School nurses' health care services will benefit from the improvement of cultural sensitivity toward young children from multicultural families. Copyright © 2015. Published by Elsevier B.V.
Longitudinal Genetic Analysis of Anxiety Sensitivity
ERIC Educational Resources Information Center
Zavos, Helena M. S.; Gregory, Alice M.; Eley, Thalia C.
2012-01-01
Anxiety sensitivity is associated with both anxiety and depression and has been shown to be heritable. Little, however, is known about the role of genetic influence on continuity and change of symptoms over time. The authors' aim was to examine the stability of anxiety sensitivity during adolescence. By using a genetically sensitive design, the…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-05
... DEPARTMENT OF COMMERCE International Trade Administration [A-475-059] Pressure Sensitive Plastic... antidumping duty finding on pressure sensitive plastic tape (PSP Tape) from Italy would be likely to lead to... of the margins likely to prevail were the finding to be revoked. See Pressure Sensitive Plastic Tape...
An Indoor Continuous Positioning Algorithm on the Move by Fusing Sensors and Wi-Fi on Smartphones.
Li, Huaiyu; Chen, Xiuwan; Jing, Guifei; Wang, Yuan; Cao, Yanfeng; Li, Fei; Zhang, Xinlong; Xiao, Han
2015-12-11
Wi-Fi indoor positioning algorithms experience large positioning error and low stability when continuously positioning terminals that are on the move. This paper proposes a novel indoor continuous positioning algorithm that is on the move, fusing sensors and Wi-Fi on smartphones. The main innovative points include an improved Wi-Fi positioning algorithm and a novel positioning fusion algorithm named the Trust Chain Positioning Fusion (TCPF) algorithm. The improved Wi-Fi positioning algorithm was designed based on the properties of Wi-Fi signals on the move, which are found in a novel "quasi-dynamic" Wi-Fi signal experiment. The TCPF algorithm is proposed to realize the "process-level" fusion of Wi-Fi and Pedestrians Dead Reckoning (PDR) positioning, including three parts: trusted point determination, trust state and positioning fusion algorithm. An experiment is carried out for verification in a typical indoor environment, and the average positioning error on the move is 1.36 m, a decrease of 28.8% compared to an existing algorithm. The results show that the proposed algorithm can effectively reduce the influence caused by the unstable Wi-Fi signals, and improve the accuracy and stability of indoor continuous positioning on the move.
Kim, Seon Young; Kim, Hyunjin; Park, Yeongchun; Lim, Jinsook; Kim, Jimyung; Koo, Sun Hoe; Kwon, Gye Cheol
2017-06-01
On-site drugs of abuse testing devices have undergone continuous improvement. We evaluated three devices with different designs: an automated reader, the Multi-Drug Screen Test Device with DxLINK (DxLINK; Innovacon, Alere, San Diego, USA) and two colorimetric immunoassays, the One Step Multi-Line Screen Panel with Integrated E-Z Split Key Cup II (E-Z Cup; Innovacon, Alere) and the One Step Multi-Drug Screen Panel card (Multi4 card; Alere, Abon Biopharm, Hangzhou, China). Eleven drugs [amphetamine, secobarbital, oxazepam, buprenorphine, benzoylecgonine, methylenedioxymethamphetamine (MDMA), 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THC), methamphetamine, methadone, morphine and nortriptyline] were tested using the DxLINK and E-Z Cup. Four drugs (benzoylecgonine, THC, methamphetamine and morphine) were tested using the Multi4 card using control materials (Detectabuse Stat-Skreen; Biochemical Diagnostics, Edgewood, NY, USA). The concentrations (-50%, -25%, +25%, +50% and 3× cut-off values) of the control materials were confirmed by mass spectrometry. Concordance rates were calculated around cut-offs. All devices showed high overall agreement rates of >90% with a few exceptions: the DxLINK exhibited lower sensitivity for benzoylecgonine, methadone and nortriptyline (60% and 30%, 92% and 40%, and 96% and 60% sensitivity at +50% and +25% cut-off levels, respectively). The E-Z Cup exhibited lower sensitivity for oxazepam and nortriptyline (97% and 50%, and 97% and 40% sensitivity at +50% and +25% cut-off levels, respectively). We additionally evaluated test-band color by visual inspection using a standard color-scale card. When detailed color criteria for determination of positivity were applied for the E-Z Cup, using slightly less stringent criteria, oxazepam, buprenorphine, MDMA and nortriptyline showed increases in sensitivity from 70-80% to 90-100%, all with a specificity above 98%. Overall, all devices exhibited satisfactory performance at ±50% cut-off levels for commonly used drugs, with the exception of lower sensitivity for cocaine testing for DxLINK. Careful evaluation of devices and elaborate calibration of visual interpretation for determining positivity may help improve the performance of these devices. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Practical Considerations for Optimizing Position Sensitivity in Arrays of Position-sensitive TES's
NASA Technical Reports Server (NTRS)
Smith, Stephen J.; Bandler, Simon R.; Figueroa-Feliciano, Encetali; Iyomoto, Naoko; Kelley, Richard L.; Kilbourne, Caroline A.; Porder, Frederick S.; Sadleir, John E.
2007-01-01
We are developing Position-Sensitive Transitions-Edge Sensors (PoST's) for future X-ray astronomy missions such as NASA's Constellation-X. The PoST consists of one or more Transitions Edge Sensors (TES's) thermally connected to a large X-ray absorber, which through heat diffusion, gives rise to position dependence. The development of PoST's is motivated by the desire to achieve the largest the focal-plan coverage with the fewest number of readout channels. In order to develop a practical array, consisting of an inner pixellated core with an outer array of large absorber PoST's, we must be able to simultaneously read out all (-1800) channels in the array. This is achievable using time division multiplexing (TDM), but does set stringent slew rate requirements on the array. Typically, we must damp the pulses to reduce the slew rate of the input signal to the TDM. This is achieved by applying a low-pass analog filter with large inductance to the signal. This attenuates the high frequency components of the signal, essential for position discrimination in PoST's, relative to the white noise of the readout chain and degrades the position sensitivity. Using numerically simulated data, we investigate the position sensing ability of typical PoST designs under such high inductance conditions. We investigate signal-processing techniques for optimal determination of the event position and discuss the practical considerations for real-time implementation.
Malmström, Eva-Maj; Karlberg, Mikael; Holmström, Eva; Fransson, Per-Anders; Hansson, Gert-Ake; Magnusson, Måns
2010-06-01
The ability to reproduce a specified head-on-trunk position can be an indirect test of cervical proprioception. This ability is affected in subjects with neck pain, but it is unclear whether and how much pain or continuous muscle contraction factors contribute to this effect. We studied the influence of a static unilateral neck muscle contraction task (5 min of lateral flexion at 30% of maximal voluntary contraction) on head repositioning ability in 20 subjects (10 women, 10 men; mean age 37 years) with healthy necks. Head repositioning ability was tested in the horizontal plane with 30 degrees target and neutral head position tests; head position was recorded by Zebris((R)), an ultrasound-based motion analyser. Head repositioning ability was analysed for accuracy (mean of signed differences between introduced and reproduced positions) and precision (standard deviation of the differences). Accuracy of head repositioning ability increased significantly after the muscle contraction task, as the normal overshoot was reduced. An average overshoot of 7.1 degrees decreased to 4.6 degrees after the muscle contraction task for the 30 degrees target and from 2.2 degrees to 1.4 degrees for neutral head position. The increased accuracy was most pronounced for movements directed towards the activated side. Hence, prolonged unilateral neck muscle contraction may increase the sensitivity of cervical proprioceptors.
Identification of the need for home visiting nurse: development of a new assessment tool
Taguchi, Atsuko; Nagata, Satoko; Naruse, Takashi; Kuwahara, Yuki; Yamaguchi, Takuhiro; Murashima, Sachiyo
2014-01-01
Objective To develop a Home Visiting Nursing Service Need Assessment Form (HVNS-NAF) to standardize the decision about the need for home visiting nursing service. Methods The sample consisted of older adults who had received coordinated services by care managers. We defined the need for home visiting nursing service by elderly individuals as the decision of the need by a care manager so that the elderly can continue to live independently. Explanatory variables included demographic factors, medical procedure, severity of illness, and caregiver variables. Multiple logistic regression was carried out after univariate analyses to decide the variables to include and the weight of each variable in the HVNS-NAF. We then calculated the sensitivity and specificity of each cutoff value, and defined the score with the highest sensitivity and specificity as the cutoff value. Results Nineteen items were included in the final HVNS-NAF. When the cutoff value was 2 points, the sensitivity was 77.0%, specificity 68.5%, and positive predictive value 56.8%. Conclusions HVNS-NAF is the first validated standard based on characteristics of elderly clients who required home visiting nursing service. Using the HVNS-NAF may result in reducing the unmet need for home visiting nursing service and preventing hospitalization. PMID:24665229
Sexual-perception processes in acquaintance-targeted sexual aggression.
Treat, Teresa A; Viken, Richard J
2018-05-01
This study analyzes data from seven published studies to examine whether three performance-based indices of men's misperception of women's sexual interest (MSI), derived from a self-report questionnaire, are associated with sexual-aggression history, rape-supportive attitudes, sociosexuality, problem drinking, and self-reported MSI. Almost 2000 undergraduate men judged the justifiability of a man's increasingly unwanted advances toward a woman on the Heterosocial Perception Survey-Revised. Participants self-reported any sexual-aggression history, and some completed questionnaires assessing rape-supportive attitudes, sociosexuality, problem drinking, and self-reported MSI. A three-parameter logistic function was fitted to participants' justifiability ratings within a non-linear mixed-effects framework, which provided precise participant-specific estimates of three sexual-perception processes (baseline justifiability, bias, and sensitivity). Sexual-aggression history and rape-supportive attitudes predicted: (a) reduced sensitivity to women's affect; (b) more liberal biases, such that the woman's affect had to be more negative before justifiability ratings dropped substantially; and (c) greater baseline justifiability of continued advances after a positive response. Sexual-aggression history and attitudes correlated more strongly with sensitivity than baseline justifiability; remaining variables showed the opposite pattern. This work underscores the role of sexual-perception processes in sexual aggression and illustrates the derivation of performance-based estimates of sexual-perception processes from questionnaire responses. © 2018 Wiley Periodicals, Inc.
Henderson, Rory; Day-Lewis, Frederick D.; Abarca, Elena; Harvey, Charles F.; Karam, Hanan N.; Liu, Lanbo; Lane, John W.
2010-01-01
Electrical resistivity imaging has been used in coastal settings to characterize fresh submarine groundwater discharge and the position of the freshwater/salt-water interface because of the relation of bulk electrical conductivity to pore-fluid conductivity, which in turn is a function of salinity. Interpretation of tomograms for hydrologic processes is complicated by inversion artifacts, uncertainty associated with survey geometry limitations, measurement errors, and choice of regularization method. Variation of seawater over tidal cycles poses unique challenges for inversion. The capabilities and limitations of resistivity imaging are presented for characterizing the distribution of freshwater and saltwater beneath a beach. The experimental results provide new insight into fresh submarine groundwater discharge at Waquoit Bay National Estuarine Research Reserve, East Falmouth, Massachusetts (USA). Tomograms from the experimental data indicate that fresh submarine groundwater discharge may shut down at high tide, whereas temperature data indicate that the discharge continues throughout the tidal cycle. Sensitivity analysis and synthetic modeling provide insight into resolving power in the presence of a time-varying saline water layer. In general, vertical electrodes and cross-hole measurements improve the inversion results regardless of the tidal level, whereas the resolution of surface arrays is more sensitive to time-varying saline water layer.
Takasu, Nobuyuki; Matsushita, Mina
2012-01-01
Two TRAbs: TSBAb and TSAb. TSBAb causes hypothyroidism. TSAb causes Graves' hyperthyroidism. TSBAb and TSAb block TSH-binding to cells as TRAb, measured as TSH-binding inhibitory immunoglobulin (TBII). We reevaluate TSBAb and TSAb. We studied TSBAb, TSAb, and TBII over 10 years in 34 TSBAb-positives with hypothyroidism and in 98 TSAb-positives with hyperthyroidism. Half of the 34 TSBAb-positives with hypothyroidism continued to have persistently positive TSBAb, continued to have hypothyroidism, and did not recover from hypothyroidism. Ten of the 98 TSAb-positives with hyperthyroidism continued to have positive TSAb and continued to have hyperthyroidism. TSBAb had disappeared in 15 of the 34 TSBAb-positives with hypothyroidism. With the disappearance of TSBAb, recovery from hypothyroidism was noted in 13 (87%) of the 15 patients. TSAb had disappeared in 73 of the 98 TSAb-positives with hyperthyroidism. With the disappearance of TSAb, remissions of hyperthyroidism were noted in 60 (82%) of the 73. Two of the 34 TSBAb-positives with hypothyroidism developed TSAb-positive Graves' hyperthyroidism. Two of the 98 TSAb-positive Graves' patients with hyperthyroidism developed TSBAb-positive hypothyroidism. TSBAb and TSAb are TRAbs. TSBAb-hypothyroidism and TSAb-hyperthyroidism may be two aspects of one disease (TRAb disease). Two forms of autoimmune thyroiditis: atrophic and goitrous. We followed 34 TSBAb-positive patients with hypothyroidism (24 atrophic and 10 goitrous) over 10 years. All of the 10 TSBAb-positive goitrous patients recovered from hypothyroidism and 19 (79%) of the 24 TSBAb-positive atrophic patients continued to have hypothyroidism. PMID:22655217
Curved position-sensitive detector for X-ray crystallography
NASA Astrophysics Data System (ADS)
Izumi, T.
1980-11-01
A new curved position-sensitive proportional detector has been constructed for X-ray crystallography. A very hard steel wire 0.2 mm in diameter was used as a single anode wire. It was bent to a radius of 6.5 cm and was suspended elastically in a wide 160° 2θ angular aperture. An amplifier and ADC-per-cathode strip system was made in order to encode the position. The spatial resolution is better than 0.37 mm (fwhm) along the curved anode wire, and this value corresponds to an angular resolution of 0.28° in 2θ. It is shown that a thick hard anode wire is quite suitable for use as a curved position-sensitive detector.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, S; Chao, C; Columbia University, NY, NY
2014-06-01
Purpose: This study investigates the calibration error of detector sensitivity for MapCheck due to inaccurate positioning of the device, which is not taken into account by the current commercial iterative calibration algorithm. We hypothesize the calibration is more vulnerable to the positioning error for the flatten filter free (FFF) beams than the conventional flatten filter flattened beams. Methods: MapCheck2 was calibrated with 10MV conventional and FFF beams, with careful alignment and with 1cm positioning error during calibration, respectively. Open fields of 37cmx37cm were delivered to gauge the impact of resultant calibration errors. The local calibration error was modeled as amore » detector independent multiplication factor, with which propagation error was estimated with positioning error from 1mm to 1cm. The calibrated sensitivities, without positioning error, were compared between the conventional and FFF beams to evaluate the dependence on the beam type. Results: The 1cm positioning error leads to 0.39% and 5.24% local calibration error in the conventional and FFF beams respectively. After propagating to the edges of MapCheck, the calibration errors become 6.5% and 57.7%, respectively. The propagation error increases almost linearly with respect to the positioning error. The difference of sensitivities between the conventional and FFF beams was small (0.11 ± 0.49%). Conclusion: The results demonstrate that the positioning error is not handled by the current commercial calibration algorithm of MapCheck. Particularly, the calibration errors for the FFF beams are ~9 times greater than those for the conventional beams with identical positioning error, and a small 1mm positioning error might lead to up to 8% calibration error. Since the sensitivities are only slightly dependent of the beam type and the conventional beam is less affected by the positioning error, it is advisable to cross-check the sensitivities between the conventional and FFF beams to detect potential calibration errors due to inaccurate positioning. This work was partially supported by a DOD Grant No.; DOD W81XWH1010862.« less
Jeon, Shinyoung; Neppl, Tricia K.
2015-01-01
The current study examined intergenerational continuity in economic hardship, parental positivity, and positive parenting across generations based on both the Family Stress Model and the Family Resilience Framework. The study included 220 generation one (G1) parents, their target youth (generation two: G2) who participated from adolescence through adulthood, and the target’s child (generation three: G3). Assessments included observational and self-report measures. Results indicated that G1 economic hardship negatively influenced both G1 positivity and G1 positive parenting. Similarly, G2 economic hardship was negatively related to both G2 positivity and G2 positive parenting which, in turn, was associated with G3 positive behavior to G2. For both G1 and G2, parental positivity mediated the association between economic hardship and positive parenting. G2 economic hardship was indirectly related to G3 positive behavior through G2 parental positivity and positive parenting. An important finding is that the intergenerational continuity of economic hardship, positivity, and positive parenting were transmitted from G1 to G2. Results suggest that even in times of economic adversity, parental positivity and positive parenting were transmitted from G1 parents to their G2 youth during adulthood. Such continuity seems to influence the positive behavior of the G3 children. PMID:26371448
Interpersonal sensitivity and persistent attenuated psychotic symptoms in adolescence.
Masillo, Alice; Brandizzi, M; Valmaggia, L R; Saba, R; Lo Cascio, N; Lindau, J F; Telesforo, L; Venturini, P; Montanaro, D; Di Pietro, D; D'Alema, M; Girardi, P; Fiori Nastro, P
2018-03-01
Interpersonal sensitivity defines feelings of inner-fragility in the presence of others due to the expectation of criticism or rejection. Interpersonal sensitivity was found to be related to attenuated positive psychotic symptom during the prodromal phase of psychosis. The aims of this study were to examine if high level of interpersonal sensitivity at baseline are associated with the persistence of attenuated positive psychotic symptoms and general psychopathology at 18-month follow-up. A sample of 85 help-seeking individuals (mean age = 16.6, SD = 5.05) referred an Italian early detection project, completed the interpersonal sensitivity measure and the structured interview for prodromal symptoms (SIPS) at baseline and were assessed at 18-month follow-up using the SIPS. Results showed that individuals with high level of interpersonal sensitivity at baseline reported high level of attenuated positive psychotic symptoms (i.e., unusual thought content) and general symptoms (i.e., depression, irritability and low tolerance to daily stress) at follow-up. This study suggests that being "hypersensitive" to interpersonal interactions is a psychological feature associated with attenuated positive psychotic symptoms and general symptoms, such as depression and irritability, at 18-month follow-up. Assessing and treating inner-self fragilities may be an important step of early detection program to avoid the persistence of subtle but very distressing long-terms symptoms.
Björnsdottir, Sigridur; Øksnes, Marianne; Isaksson, Magnus; Methlie, Paal; Nilsen, Roy M; Hustad, Steinar; Kämpe, Olle; Hulting, Anna-Lena; Husebye, Eystein S; Løvås, Kristian; Nyström, Thomas; Bensing, Sophie
2015-07-01
Conventional glucocorticoid replacement therapy in patients with Addison's disease (AD) is unphysiological with possible adverse effects on mortality, morbidity and quality of life. The diurnal cortisol profile can likely be restored by continuous subcutaneous hydrocortisone infusion (CSHI). The aim of this study was to compare circadian hormone rhythms and insulin sensitivity in conventional thrice-daily regimen of glucocorticoid replacement therapy with CSHI treatment in patients with AD. An open, randomized, two-period, 12-week crossover multicentre trial in Norway and Sweden. Ten Norwegian patients were admitted for 24-h sampling of hormone profiles. Fifteen Swedish patients underwent euglycaemic-hyperinsulinaemic clamp. Thrice-daily regimen of oral hydrocortisone (OHC) and CSHI treatment. We measured the circadian rhythm of cortisol, adrenocorticotropic hormone (ACTH), growth hormone (GH), insulin-like growth factor-1, (IGF-1), IGF-binding protein-3 (IGFBP-3), glucose, insulin and triglycerides during OHC and CSHI treatment. Euglycaemic-hyperinsulinaemic clamp was used to assess insulin sensitivity. Continuous subcutaneous hydrocortisone infusion provided a more physiological circadian cortisol curve including a late-night cortisol surge. ACTH levels showed a near normal circadian variation for CSHI. CSHI prevented a continuous decrease in glucose during the night. No difference in insulin sensitivity was observed between the two treatment arms. Continuous subcutaneous hydrocortisone infusion replacement re-established a circadian cortisol rhythm and normalized the ACTH levels. Patients with CSHI replacement had a more stable night-time glucose level compared with OHC without compromising insulin sensitivity. Thus, restoring night-time cortisol levels might be advantageous for patients with AD. © 2015 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Preziosi, E.; Sánchez, S.; González, A. J.; Pani, R.; Borrazzo, C.; Bettiol, M.; Rodriguez-Alvarez, M. J.; González-Montoro, A.; Moliner, L.; Benlloch, J. M.
2016-12-01
One of the technical objectives of the MindView project is developing a brain-dedicated PET insert based on monolithic scintillation crystals. It will be inserted in MRI systems with the purpose to obtain simultaneous PET and MRI brain images. High sensitivity, high image quality performance and accurate detection of the Depth-of-Interaction (DoI) of the 511keV photons are required. We have developed a DoI estimation method, dedicated to monolithic scintillators, allowing continuous DoI estimation and a DoI-dependent algorithm for the estimation of the photon planar impact position, able to improve the single module imaging capabilities. In this work, through experimental measurements, the proposed methods have been used for the estimation of the impact positions within the monolithic crystal block. We have evaluated the PET system performance following the NEMA NU 4-2008 protocol by reconstructing the images using the STIR 3D platform. The results obtained with two different methods, providing discrete and continuous DoI information, are compared with those obtained from an algorithm without DoI capabilities and with the ideal response of the detector. The proposed DoI-dependent imaging methods show clear improvements in the spatial resolution (FWHM) of reconstructed images, allowing to obtain values from 2mm (at the center FoV) to 3mm (at the FoV edges).
40 CFR 766.18 - Method sensitivity.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Method sensitivity. 766.18 Section 766.18 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT DIBENZO-PARA-DIOXINS/DIBENZOFURANS General Provisions § 766.18 Method sensitivity. The target level of...
40 CFR 766.18 - Method sensitivity.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Method sensitivity. 766.18 Section 766.18 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT DIBENZO-PARA-DIOXINS/DIBENZOFURANS General Provisions § 766.18 Method sensitivity. The target level of...
40 CFR 766.18 - Method sensitivity.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Method sensitivity. 766.18 Section 766.18 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT DIBENZO-PARA-DIOXINS/DIBENZOFURANS General Provisions § 766.18 Method sensitivity. The target level of...
40 CFR 766.18 - Method sensitivity.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Method sensitivity. 766.18 Section 766.18 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT DIBENZO-PARA-DIOXINS/DIBENZOFURANS General Provisions § 766.18 Method sensitivity. The target level of...
40 CFR 766.18 - Method sensitivity.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Method sensitivity. 766.18 Section 766.18 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT DIBENZO-PARA-DIOXINS/DIBENZOFURANS General Provisions § 766.18 Method sensitivity. The target level of...
Evaluation of in silico development of aquatic toxicity species sensitivity distributions
Determining the sensitivity of a diversity of species to environmental contaminants continues to be a significant challenge in ecological risk assessment because toxicity data are generally limited to a few standard test species. This study assessed whether species sensitivity d...
20 CFR 404.1217 - Continuation of coverage.
Code of Federal Regulations, 2011 CFR
2011-04-01
... employees continues as follows: (a) Absolute coverage group. Generally, the services of an employee covered as a part of an absolute coverage group (see § 404.1205) continue to be covered indefinitely. A position covered as a part of an absolute coverage group continues to be covered even if the position later...
20 CFR 404.1217 - Continuation of coverage.
Code of Federal Regulations, 2010 CFR
2010-04-01
... employees continues as follows: (a) Absolute coverage group. Generally, the services of an employee covered as a part of an absolute coverage group (see § 404.1205) continue to be covered indefinitely. A position covered as a part of an absolute coverage group continues to be covered even if the position later...
van Winkel, Mark; Peeters, Frenk; van Winkel, Ruud; Kenis, Gunter; Collip, Dina; Geschwind, Nicole; Jacobs, Nele; Derom, Catherine; Thiery, Evert; van Os, Jim; Myin-Germeys, Inez; Wichers, Marieke
2014-06-01
A previous study reported that social stress sensitivity is moderated by the brain-derived-neurotrophic-factor(Val66Met) (BDNF rs6265) genotype. Additionally, positive emotions partially neutralize this moderating effect. The current study aimed to: (i) replicate in a new independent sample of subjects with residual depressive symptoms the moderating effect of BDNF(Val66Met) genotype on social stress sensitivity, (ii) replicate the neutralizing impact of positive emotions, (iii) extend these analyses to other variations in the BDNF gene in the new independent sample and the original sample of non-depressed individuals. Previous findings were replicated in an experience sampling method (ESM) study. Negative Affect (NA) responses to social stress were stronger in "Val/Met" carriers of BDNF(Val66Met) compared to "Val/Val" carriers. Positive emotions neutralized the moderating effect of BDNF(Val66Met) genotype on social stress sensitivity in a dose-response fashion. Finally, two of four additional BDNF SNPs (rs11030101, rs2049046) showed similar moderating effects on social stress-sensitivity across both samples. The neutralizing effect of positive emotions on the moderating effects of these two additional SNPs was found in one sample. In conclusion, ESM has important advantages in gene-environment (GxE) research and may attribute to more consistent findings in future GxE research. This study shows how the impact of BDNF genetic variation on depressive symptoms may be explained by its impact on subtle daily life responses to social stress. Further, it shows that the generation of positive affect (PA) can buffer social stress sensitivity and partially undo the genetic susceptibility. Copyright © 2014 Elsevier B.V. and ECNP. All rights reserved.
Realization of discrete quantum billiards in a two-dimensional optical lattice
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krimer, Dmitry O.; Max-Planck Institute for the Physics of Complex Systems, Noethnitzer Strasse 38, D-01187 Dresden; Khomeriki, Ramaz
2011-10-15
We propose a method for optical visualization of the Bose-Hubbard model with two interacting bosons in the form of two-dimensional (2D) optical lattices consisting of optical waveguides, where the waveguides at the diagonal are characterized by different refractive indices than others elsewhere, modeling the boson-boson interaction. We study the light intensity distribution function averaged over the direction of propagation for both ordered and disordered cases, exploring the sensitivity of the averaged picture with respect to the beam injection position. For our finite systems, the resulting patterns are reminiscent the ones set in billiards, and therefore we introduce a definition ofmore » discrete quantum billiards and discuss the possible relevance to its well-established continuous counterpart.« less
Controlling Chaos Via Knowledge of Initial Condition for a Curved Structure
NASA Technical Reports Server (NTRS)
Maestrello, L.
2000-01-01
Nonlinear response of a flexible curved panel exhibiting bifurcation to fully developed chaos is demonstrated along with the sensitivity to small perturbation from the initial conditions. The response is determined from the measured time series at two fixed points. The panel is forced by an external nonharmonic multifrequency and monofrequency sound field. Using a low power time-continuous feedback control, carefully tuned at each initial condition, produces large long-term effects on the dynamics toward taming chaos. Without the knowledge of the initial conditions, control may be achieved by destructive interference. In this case, the control power is proportional to the loading power. Calculation of the correlation dimension and the estimation of positive Lyapunov exponents, in practice, are the proof of chaotic response.
Framing sound: Using expectations to reduce environmental noise annoyance.
Crichton, Fiona; Dodd, George; Schmid, Gian; Petrie, Keith J
2015-10-01
Annoyance reactions to environmental noise, such as wind turbine sound, have public health implications given associations between annoyance and symptoms related to psychological distress. In the case of wind farms, factors contributing to noise annoyance have been theorised to include wind turbine sound characteristics, the noise sensitivity of residents, and contextual aspects, such as receiving information creating negative expectations about sound exposure. The experimental aim was to assess whether receiving positive or negative expectations about wind farm sound would differentially influence annoyance reactions during exposure to wind farm sound, and also influence associations between perceived noise sensitivity and noise annoyance. Sixty volunteers were randomly assigned to receive either negative or positive expectations about wind farm sound. Participants in the negative expectation group viewed a presentation which incorporated internet material indicating that exposure to wind turbine sound, particularly infrasound, might present a health risk. Positive expectation participants viewed a DVD which framed wind farm sound positively and included internet information about the health benefits of infrasound exposure. Participants were then simultaneously exposed to sub-audible infrasound and audible wind farm sound during two 7 min exposure sessions, during which they assessed their experience of annoyance. Positive expectation participants were significantly less annoyed than negative expectation participants, while noise sensitivity only predicted annoyance in the negative group. Findings suggest accessing negative information about sound is likely to trigger annoyance, particularly in noise sensitive people and, importantly, portraying sound positively may reduce annoyance reactions, even in noise sensitive individuals. Copyright © 2015 Elsevier Inc. All rights reserved.
Johnson, Amy; Dawson, Jeffrey; Rizzo, Matthew
2012-01-01
Summary Driving simulators provide precise information on vehicular position at high capture rates. To analyze such data, we have previously proposed a time series model that reduces lateral position data into several parameters for measuring lateral control, and have shown that these parameters can detect differences between neurologically impaired and healthy drivers (Dawson et al, 2010a). In this paper, we focus on the “re-centering” parameter of this model, and test whether the parameter estimates are associated with off-road neuropsychological tests and/or with on-road safety errors. We assessed such correlations in 127 neurologically healthy drivers, ages 40 to 89. We found that our re-centering parameter had significant correlations with five neuropsychological tests: Judgment of Line Orientation (r = 0.38), Block Design (r = 0.27), Contrast Sensitivity (r = 0.31), Near Visual Acuity (r = -0.26), and Grooved Pegboard (r = -0.25). We also found that our re-centering parameter was associated with on-road safety errors at stop signs (r = -0.34) and on-road safety errors during turns (r = -0.22). These results suggest that our re-centering parameter may be a useful tool for measuring and monitoring ability to maintain vehicular lateral control. As GPS-based technology continues to improve in precision and reliability to measure vehicular positioning, our time-series model may potentially be applied as an automated index of driver performance in real world settings that is sensitive to cognitive decline. This work was supported by NIH/NIA awards AG17177, AG15071, and NS044930, and by a scholarship from Nissan Motor Company. PMID:24273756
Relative Performance of HPV and Cytology Components of Cotesting in Cervical Screening.
Schiffman, Mark; Kinney, Walter K; Cheung, Li C; Gage, Julia C; Fetterman, Barbara; Poitras, Nancy E; Lorey, Thomas S; Wentzensen, Nicolas; Befano, Brian; Schussler, John; Katki, Hormuzd A; Castle, Philip E
2018-05-01
The main goal of cervical screening programs is to detect and treat precancer before cancer develops. Human papillomavirus (HPV) testing is more sensitive than cytology for detecting precancer. However, reports of rare HPV-negative, cytology-positive cancers are motivating continued use of both tests (cotesting) despite increased testing costs. We quantified the detection of cervical precancer and cancer by cotesting compared with HPV testing alone at Kaiser Permanente Northern California (KPNC), where 1 208 710 women age 30 years and older have undergone triennial cervical cotesting since 2003. Screening histories preceding cervical cancers (n = 623) and precancers (n = 5369) were examined to assess the relative contribution of the cytology and HPV test components in identifying cases. The performances of HPV testing and cytology were compared using contingency table methods, general estimating equation models, and nonparametric statistics; all statistical tests were two-sided. HPV testing identified more women subsequently diagnosed with cancer (P < .001) and precancer (P < .001) than cytology. HPV testing was statistically significantly more likely to be positive for cancer at any time point (P < .001), except within 12 months (P = .10). HPV-negative/cytology-positive results preceded only small fractions of cases of precancer (3.5%) and cancer (5.9%); these cancers were more likely to be regional or distant stage with squamous histopathology than other cases. Given the rarity of cancers among screened women, the contribution of cytology to screening translated to earlier detection of at most five cases per million women per year. Two-thirds (67.9%) of women found to have cancer during 10 years of follow-up at KPNC were detected by the first cotest performed. The added sensitivity of cotesting vs HPV alone for detection of treatable cancer affected extremely few women.
Ojha, A R; Aryal, U R
2014-01-01
Urinary tract infection is a common problem in children and its early diagnosis and treatment is important to prevent long-term complications. Urine dipstick can be an important tool in this respect. The aim of this study is to look at the utility of urine dipstick as a diagnostic tool for UTI and will also see the clinical profile of children with UTI and sensitivity pattern of antibiotics among the isolates of urine culture. Urine samples of all children below 14 years of age who were suspected of urinary tract infection were sent for routine microscopic examination and dipstick testing. Urine culture and sensitivity were sent for those samples that were tested positive for nitrite, leucocyte esterase activity or both. For every fifth sample, which is dipstick negative, a culture and sensitivity testing was done. Among 110 children enrolled, 32(29%) cases had significant bacteriuria. Out of 32 culture positive cases 18(56%) were female. Fever was the main complaint (62.5%)). Escherichia Coli was isolated in 81.25% of cases. Amikacin was sensitive in 93% and amoxicillinwas resistant in 82%. The sensitivity, specificity, positive predictive value, negative predictive value of nitrite test was 65%, 80%, 58%, 85% respectively; those of leucocyte esterase are 84%, 55%, 43%, 89% respectively; those for significant microscopic pyuria >10/hpf were 65%, 74%, 51%, 84% respectively. E. Coli is the commonest uropathogen in children with UTI. Amikacin is the most sensitive antibiotic against all the isolates. A positive dipstick both for nitrite and leucocyte esterase is associated with high sensitivity and specificity for urinary tract infection as compared to either of them positive alone. In addition, urine WBC ≥10/hpf is associated with high probability of UTI.
Automatic detection of ECG cable interchange by analyzing both morphology and interlead relations.
Han, Chengzong; Gregg, Richard E; Feild, Dirk Q; Babaeizadeh, Saeed
2014-01-01
ECG cable interchange can generate erroneous diagnoses. For algorithms detecting ECG cable interchange, high specificity is required to maintain a low total false positive rate because the prevalence of interchange is low. In this study, we propose and evaluate an improved algorithm for automatic detection and classification of ECG cable interchange. The algorithm was developed by using both ECG morphology information and redundancy information. ECG morphology features included QRS-T and P-wave amplitude, frontal axis and clockwise vector loop rotation. The redundancy features were derived based on the EASI™ lead system transformation. The classification was implemented using linear support vector machine. The development database came from multiple sources including both normal subjects and cardiac patients. An independent database was used to test the algorithm performance. Common cable interchanges were simulated by swapping either limb cables or precordial cables. For the whole validation database, the overall sensitivity and specificity for detecting precordial cable interchange were 56.5% and 99.9%, and the sensitivity and specificity for detecting limb cable interchange (excluding left arm-left leg interchange) were 93.8% and 99.9%. Defining precordial cable interchange or limb cable interchange as a single positive event, the total false positive rate was 0.7%. When the algorithm was designed for higher sensitivity, the sensitivity for detecting precordial cable interchange increased to 74.6% and the total false positive rate increased to 2.7%, while the sensitivity for detecting limb cable interchange was maintained at 93.8%. The low total false positive rate was maintained at 0.6% for the more abnormal subset of the validation database including only hypertrophy and infarction patients. The proposed algorithm can detect and classify ECG cable interchanges with high specificity and low total false positive rate, at the cost of decreased sensitivity for certain precordial cable interchanges. The algorithm could also be configured for higher sensitivity for different applications where a lower specificity can be tolerated. Copyright © 2014 Elsevier Inc. All rights reserved.
Dynamic tuning of chemiresistor sensitivity using mechanical strain
Martin, James E; Read, Douglas H
2014-09-30
The sensitivity of a chemiresistor sensor can be dynamically tuned using mechanical strain. The increase in sensitivity is a smooth, continuous function of the applied strain, and the effect can be reversible. Sensitivity tuning enables the response curve of the sensor to be dynamically optimized for sensing analytes, such as volatile organic compounds, over a wide concentration range.
Johannsen, H; Nolan, R; Pascoe, E M; Cuthbert, P; Noble, V; Corderoy, T; Franzmann, A; Loh, R; Prescott, S L
2011-07-01
The rise in peanut allergy is a source of considerable burden in the community. A growing number of preschoolchildren have been identified as peanut sensitized in the course of investigation of other allergic conditions. Although many have never knowingly ingested peanuts and their clinical reactivity is not known, it has been common practice to place these children on avoidance diets for many years. To determine the utility of skin prick tests (SPT) and fluorescent-enzyme immunoassays (FEIA) for identifying either peanut allergy or tolerance in preschoolchildren with peanut sensitization. Forty-nine preschoolchildren (<5 years of age) with peanut sensitization (SPT ≥ 2 mm or peanut-specific IgE ≥ 0.35 kU/L) but unknown clinical reactivity had graded open peanut challenges reaching a total of 11 g. A positive challenge was defined as an objective IgE-mediated reaction during challenge or the 2-h observation. Forty-nine percent (24/49) of children had positive challenges. An SPT of >7 mm on the day of challenge predicted a positive challenge with a sensitivity of 83% and a negative predictive value (NPV) of 84%. An FEIA of >2.0 kU/L showed a sensitivity of 79% and an NPV of 80%. Predicting challenge outcome from a combination of SPT and FEIA (SPT >7 and/or FEIA >2 is positive) increased sensitivity to 96% and NPV to 95%. At least half of preschoolchildren with peanut sensitization and no antecedent history of peanut ingestion can tolerate peanuts. A SPT<7 mm and FEIA<2 kU/L identify children most likely to tolerate peanut, with only a 5% likelihood of failing an oral challenge. This study assists clinicians considering challenges in very young peanut-sensitized children. © 2011 Blackwell Publishing Ltd.
ERIC Educational Resources Information Center
Rugani, Rosa; Regolin, Lucia; Vallortigara, Giorgio
2010-01-01
Newborn chicks were tested for their sensitivity to number vs. continuous physical extent of artificial objects they had been reared with soon after hatching. Because of the imprinting process, such objects were treated by chicks as social companions. We found that when the objects were similar, chicks faced with choices between 1 vs. 2 or 2 vs. 3…
Kushida, Clete A.; Nichols, Deborah A.; Holmes, Tyson H.; Quan, Stuart F.; Walsh, James K.; Gottlieb, Daniel J.; Simon, Richard D.; Guilleminault, Christian; White, David P.; Goodwin, James L.; Schweitzer, Paula K.; Leary, Eileen B.; Hyde, Pamela R.; Hirshkowitz, Max; Green, Sylvan; McEvoy, Linda K.; Chan, Cynthia; Gevins, Alan; Kay, Gary G.; Bloch, Daniel A.; Crabtree, Tami; Dement, William C.
2012-01-01
Study Objective: To determine the neurocognitive effects of continuous positive airway pressure (CPAP) therapy on patients with obstructive sleep apnea (OSA). Design, Setting, and Participants: The Apnea Positive Pressure Long-term Efficacy Study (APPLES) was a 6-month, randomized, double-blind, 2-arm, sham-controlled, multicenter trial conducted at 5 U.S. university, hospital, or private practices. Of 1,516 participants enrolled, 1,105 were randomized, and 1,098 participants diagnosed with OSA contributed to the analysis of the primary outcome measures. Intervention: Active or sham CPAP Measurements: Three neurocognitive variables, each representing a neurocognitive domain: Pathfinder Number Test-Total Time (attention and psychomotor function [A/P]), Buschke Selective Reminding Test-Sum Recall (learning and memory [L/M]), and Sustained Working Memory Test-Overall Mid-Day Score (executive and frontal-lobe function [E/F]) Results: The primary neurocognitive analyses showed a difference between groups for only the E/F variable at the 2 month CPAP visit, but no difference at the 6 month CPAP visit or for the A/P or L/M variables at either the 2 or 6 month visits. When stratified by measures of OSA severity (AHI or oxygen saturation parameters), the primary E/F variable and one secondary E/F neurocognitive variable revealed transient differences between study arms for those with the most severe OSA. Participants in the active CPAP group had a significantly greater ability to remain awake whether measured subjectively by the Epworth Sleepiness Scale or objectively by the maintenance of wakefulness test. Conclusions: CPAP treatment improved both subjectively and objectively measured sleepiness, especially in individuals with severe OSA (AHI > 30). CPAP use resulted in mild, transient improvement in the most sensitive measures of executive and frontal-lobe function for those with severe disease, which suggests the existence of a complex OSA-neurocognitive relationship. Clinical Trial Information: Registered at clinicaltrials.gov. Identifier: NCT00051363. Citation: Kushida CA; Nichols DA; Holmes TH; Quan SF; Walsh JK; Gottlieb DJ; Simon RD; Guilleminault C; White DP; Goodwin JL; Schweitzer PK; Leary EB; Hyde PR; Hirshkowitz M; Green S; McEvoy LK; Chan C; Gevins A; Kay GG; Bloch DA; Crabtree T; Demen WC. Effects of continuous positive airway pressure on neurocognitive function in obstructive sleep apnea patients: the Apnea Positive Pressure Long-term Efficacy Study (APPLES). SLEEP 2012;35(12):1593-1602. PMID:23204602
Rahman, Muhammad Aziz; Spurrier, Nicola; Mahmood, Mohammad Afzal; Rahman, Mahmudur; Choudhury, Sohel Reza; Leeder, Stephen
2013-01-01
Aim/objectives The study aimed to validate the Rose Angina Questionnaire (RAQ) to detect coronary heart disease (CHD) by comparing with cardiologists' diagnoses in Bangladesh. Methods Patients aged 40–75 years attending to two cardiac hospitals were diagnosed as either CHD positive or CHD negative by cardiologists. The RAQ was used to reclassify them into CHD positive [RAQ] and CHD negative [RAQ]. Findings There were 302 CHD positive [cardiologists] and 302 CHD negative [cardiologists] individuals. The RAQ reclassified 194 individuals as CHD positive [RAQ] and 409 individuals as CHD negative [RAQ]. Therefore, the RAQ had 53% sensitivity and 89% specificity. There was no difference in sensitivity and specificity during subgroup analyzes by age and gender; the sensitivity was higher among people from lower socio-economic status. Conclusion The RAQ, having moderate sensitivity but high specificity to detect CHD, can be used to screen individuals at risk of CHD in large-scale epidemiological surveys. PMID:23438610
Facer, C A; Bray, R S; Brown, J
1979-01-01
Gambian children with past or present Plasmodium falciparum malaria were investigated for the incidence of Coombs positivity using monospecific antisera. Approximately 50% were positive and the most frequent form of erythrocyte sensitization was with C3d. Other specificities, EIgG, EIgGC3d and EIgGC4bC3d were less common. Erthyrocytes were never found sensitized with IgA or IgM. There was no correlation between a positive test and age, tribal status or level of parasitaemia at presentation, although a positive test was often found in association with anaemia. Sensitized erythrocytes were present in the circulation for a period of up to 6 weeks following initial observation. The mechanism of erythrocyte sensitization is not known, but the results suggest a Type III complex-mediated hypersensitivity involving parasite antigen-antibody complexes. It is likely that these reactions contribute to the pathogenesis of the anaemia in falciparum malaria. Images FIG. 3 PMID:371880
Behera, B; Mathur, P; Gupta, B
2010-01-01
The purpose of this study was to ascertain if the simple practice of Gram stain, acridine orange stain and direct sensitivity determination of positive blood culture bottles could be used to guide early and appropriate treatment in trauma patients with clinical suspicion of sepsis. The study also aimed to evaluate the error in interpreting antimicrobial sensitivity by direct method when compared to standard method and find out if specific antibiotic-organism combination had more discrepancies. Findings from consecutive episodes of blood stream infection at an Apex Trauma centre over a 12-month period are summarized. A total of 509 consecutive positive blood cultures were subjected to Gram staining. AO staining was done in BacT/ALERT-positive Gram-stain negative blood cultures. Direct sensitivity was performed from 369 blood culture broths, showing single type of growth in Gram and acridine orange staining. Results of direct sensitivity were compared to conventional sensitivity for errors. No 'very major' discrepancy was found in this study. About 5.2 and 1.8% minor error rates were noted in gram-positive and gram-negative bacteria, respectively, while comparing the two methods. Most of the discrepancies in gram-negative bacteria were noted in beta lactam - beta lactamase inhibitor combinations. Direct sensitivity testing was not reliable for reporting of methicillin and vancomycin resistance in Staphylococci. Gram stain result together with direct sensitivity testing is required for optimizing initial antimicrobial therapy in trauma patients with clinical suspicion of sepsis. Gram staining and AO staining proved particularly helpful in the early detection of candidaemia.
Differences in sensitivity to parenting depending on child temperament: A meta-analysis.
Slagt, Meike; Dubas, Judith Semon; Deković, Maja; van Aken, Marcel A G
2016-10-01
Several models of individual differences in environmental sensitivity postulate increased sensitivity of some individuals to either stressful (diathesis-stress), supportive (vantage sensitivity), or both environments (differential susceptibility). In this meta-analysis we examine whether children vary in sensitivity to parenting depending on their temperament, and if so, which model can best be used to describe this sensitivity pattern. We tested whether associations between negative parenting and negative or positive child adjustment as well as between positive parenting and positive or negative child adjustment would be stronger among children higher on putative sensitivity markers (difficult temperament, negative emotionality, surgency, and effortful control). Longitudinal studies with children up to 18 years (k = 105 samples from 84 studies, Nmean = 6,153) that reported on a parenting-by-temperament interaction predicting child adjustment were included. We found 235 independent effect sizes for associations between parenting and child adjustment. Results showed that children with a more difficult temperament (compared with those with a more easy temperament) were more vulnerable to negative parenting, but also profited more from positive parenting, supporting the differential susceptibility model. Differences in susceptibility were expressed in externalizing and internalizing problems and in social and cognitive competence. Support for differential susceptibility for negative emotionality was, however, only present when this trait was assessed during infancy. Surgency and effortful control did not consistently moderate associations between parenting and child adjustment, providing little support for differential susceptibility, diathesis-stress, or vantage sensitivity models. Finally, parenting-by-temperament interactions were more pronounced when parenting was assessed using observations compared to questionnaires. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Egg hypersensitivity and measles-mumps-rubella vaccine administration.
Beck, S A; Williams, L W; Shirrell, M A; Burks, A W
1991-11-01
Because reports have described egg-sensitive individuals in whom anaphylaxis developed after measles vaccination, current recommendations include delaying administration of egg-derived vaccines until skin testing can be performed. Specifically, the 1988 Red Book recommends skin testing via scratch, prick, or puncture with 1:10 dilution of the vaccine and, if the result is negative, intradermal testing is suggested. The purpose of this study was to evaluate the likelihood of reaction to measles-mumps-rubella (MMR) vaccine in patients with documented egg sensitivity and to delineate the efficacy of skin-prick testing (SPT) to MMR as a predictor of hypersensitivity to the vaccine. Egg sensitivity was documented by initial SPT to egg and then, if possible, double-blind placebo-controlled food challenge (DBPCFC). Patients with a positive DBPCFC to egg or a history of anaphylactic egg sensitivity had a SPT with the MMR vaccine and then were given the MMR vaccine. Additionally, children with atopic dermatitis who had been previously proven egg sensitive via DBPCFCs were evaluated retrospectively for sensitivity to the MMR vaccine. Sixteen children with a history of egg sensitivity underwent SPT to egg, with a positive result 3 mm greater than the negative control found in 12 patients. Eight of these children had a positive DBPCFC to egg. The SPT to MMR vaccine was negative in all 16 children; vaccine administration followed with no resultant systemic problems. Three children had a local reaction at the site of injection. Twelve additional children with atopic dermatitis and egg sensitivity were reviewed. Each child had a positive SPT and DBPCFC to egg.(ABSTRACT TRUNCATED AT 250 WORDS)
Development of aquatic toxicity benchmarks for oil products using species sensitivity distributions
Determining the sensitivity of a diversity of species to spilled oil and chemically dispersed oil continues to be a significant challenge in spill response and impact assessment. We used standardized tests from the literature to develop species sensitivity distributions (SSDs) of...
Evaluation of in silico development of aquatic toxicity species sensitivity distributions (SSDs)
Determining the sensitivity of a diversity of species to environmental contaminants continues to be a significant challenge in ecological risk assessment because toxicity data are generally limited to a few standard test species. This study assessed whether species sensitivity di...
The relevance of memory sensitivity for psychological well-being in aging.
Toffalini, Enrico; Borella, Erika; Cornoldi, Cesare; De Beni, Rossana
2016-08-01
In the present study, we investigated the relationship between memory sensitivity, which describes a positive attitude to autobiographical memory and the presence of behaviors devoted to saving memories of the personal past, and psychological well-being; in particular, we tested whether their relationship would change across age groups. Three hundred eighteen participants, divided in four groups: young to middle-aged adults (20-55 years old), young-old adults (65-74 years old), old adults (75-84 years old), and old-old adults (85-97 years old), completed questionnaires on their memory sensitivity and psychological well-being. Memory sensitivity slightly decreased with age and had a positive relationship with psychological well-being that was critically moderated by age. Specifically, the relationship between memory sensitivity and psychological well-being became increasingly stronger as age increased. While memory sensitivity may have little or no particular relevance in the case of young to middle-aged adults, it has an increasingly important positive relationship with psychological well-being at later age. It is thus suggested that memory sensitivity represents a dimension that should be considered in the study and interventions on quality of life in the elderly population.
Numerical Simulation and Mechanical Design for TPS Electron Beam Position Monitors
NASA Astrophysics Data System (ADS)
Hsueh, H. P.; Kuan, C. K.; Ueng, T. S.; Hsiung, G. Y.; Chen, J. R.
2007-01-01
Comprehensive study on the mechanical design and numerical simulation for the high resolution electron beam position monitors are key steps to build the newly proposed 3rd generation synchrotron radiation research facility, Taiwan Photon Source (TPS). With more advanced electromagnetic simulation tool like MAFIA tailored specifically for particle accelerator, the design for the high resolution electron beam position monitors can be tested in such environment before they are experimentally tested. The design goal of our high resolution electron beam position monitors is to get the best resolution through sensitivity and signal optimization. The definitions and differences between resolution and sensitivity of electron beam position monitors will be explained. The design consideration is also explained. Prototype deign has been carried out and the related simulations were also carried out with MAFIA. The results are presented here. Sensitivity as high as 200 in x direction has been achieved in x direction at 500 MHz.
De Strijcker, Dorien; Lapauw, Bruno; Ouwens, D Margriet; Van de Velde, Dominique; Hansen, Dominique; Petrovic, Mirko; Cuvelier, Claude; Tonoli, Cajsa; Calders, Patrick
2018-06-01
To evaluate the effect of high intensity training (HIT) on physical fitness, basal respiratory exchange ratio (bRER), insulin sensitivity and muscle histology in overweight/obese men compared to continuous aerobic training (CAT). 16 male participants with overweight/obesity (age: 42-57 years, body mass index: 28-36 kg/m2) were randomized to HIT (n=8) or CAT (n=8) for 10 weeks, twice a week. HIT was composed of 10 minutes high intensity, 10 minutes continuous aerobic, 10 minutes high intensity exercises. CAT was composed of three times 10 minutes continuous exercising. Changes in anthropometry, physical and metabolic fitness were evaluated. Muscle histology (mitochondria and lipid content) was evaluated by transmission electron microscopy (TEM). HIT showed a significant increase for peak VO2 (P=0.01), for insulin sensitivity (AUC glucose (P<0,001), AUC insulin (P<0,001), OGTT composite score (P=0.007)) and a significant decrease of bRER (P<0.001) compared to CAT. Muscle mitochondrial content was significantly increased after HIT at the subsarcolemmal (P=0.004 number and P=0.001 surface) as well as the intermyofibrillar site (P<0.001 number and P=0.001 surface). High intensity training elicits stronger beneficial effects on physical fitness, basal RER, insulin sensitivity, and muscle mitochondrial content, as compared to continuous aerobic training.
Development of a superconducting position sensor for the Satellite Test of the Equivalence Principle
NASA Astrophysics Data System (ADS)
Clavier, Odile Helene
The Satellite Test of the Equivalence Principle (STEP) is a joint NASA/ESA mission that proposes to measure the differential acceleration of two cylindrical test masses orbiting the earth in a drag-free satellite to a precision of 10-18 g. Such an experiment would conceptually reproduce Galileo's tower of Pisa experiment with a much longer time of fall and greatly reduced disturbances. The superconducting test masses are constrained in all degrees of freedom except their axial direction (the sensitive axis) using superconducting bearings. The STEP accelerometer measures the differential position of the masses in their sensitive direction using superconducting inductive pickup coils coupled to an extremely sensitive magnetometer called a DC-SQUID (Superconducting Quantum Interference Device). Position sensor development involves the design, manufacture and calibration of pickup coils that will meet the acceleration sensitivity requirement. Acceleration sensitivity depends on both the displacement sensitivity and stiffness of the position sensor. The stiffness must kept small while maintaining stability of the accelerometer. Using a model for the inductance of the pickup coils versus displacement of the test masses, a computer simulation calculates the sensitivity and stiffness of the accelerometer in its axial direction. This simulation produced a design of pickup coils for the four STEP accelerometers. Manufacture of the pickup coils involves standard photolithography techniques modified for superconducting thin-films. A single-turn pickup coil was manufactured and produced a successful superconducting coil using thin-film Niobium. A low-temperature apparatus was developed with a precision position sensor to measure the displacement of a superconducting plate (acting as a mock test mass) facing the coil. The position sensor was designed to detect five degrees of freedom so that coupling could be taken into account when measuring the translation of the plate relative to the coil. The inductance was measured using a DC-SQUID coupled to the pickup coil. The experimental results agree with the model used in the simulation thereby validating the concept used for the design. The STEP program now has the confidence necessary to design and manufacture a position sensor for the flight accelerometer.
Sampling and position effects in the Electronically Steered Thinned Array Radiometer (ESTAR)
NASA Technical Reports Server (NTRS)
Katzberg, Stephen J.
1993-01-01
A simple engineering level model of the Electronically Steered Thinned Array Radiometer (ESTAR) is developed that allows an identification of the major effects of the sampling process involved with this technique. It is shown that the ESTAR approach is sensitive to aliasing and has a highly non-uniform sensitivity profile. It is further shown that the ESTAR approach is strongly sensitive to position displacements of the low-density sampling antenna elements.
The minimum area requirements (MAR) for giant panda: an empirical study
Qing, Jing; Yang, Zhisong; He, Ke; Zhang, Zejun; Gu, Xiaodong; Yang, Xuyu; Zhang, Wen; Yang, Biao; Qi, Dunwu; Dai, Qiang
2016-01-01
Habitat fragmentation can reduce population viability, especially for area-sensitive species. The Minimum Area Requirements (MAR) of a population is the area required for the population’s long-term persistence. In this study, the response of occupancy probability of giant pandas against habitat patch size was studied in five of the six mountain ranges inhabited by giant panda, which cover over 78% of the global distribution of giant panda habitat. The probability of giant panda occurrence was positively associated with habitat patch area, and the observed increase in occupancy probability with patch size was higher than that due to passive sampling alone. These results suggest that the giant panda is an area-sensitive species. The MAR for giant panda was estimated to be 114.7 km2 based on analysis of its occupancy probability. Giant panda habitats appear more fragmented in the three southern mountain ranges, while they are large and more continuous in the other two. Establishing corridors among habitat patches can mitigate habitat fragmentation, but expanding habitat patch sizes is necessary in mountain ranges where fragmentation is most intensive. PMID:27929520
The minimum area requirements (MAR) for giant panda: an empirical study.
Qing, Jing; Yang, Zhisong; He, Ke; Zhang, Zejun; Gu, Xiaodong; Yang, Xuyu; Zhang, Wen; Yang, Biao; Qi, Dunwu; Dai, Qiang
2016-12-08
Habitat fragmentation can reduce population viability, especially for area-sensitive species. The Minimum Area Requirements (MAR) of a population is the area required for the population's long-term persistence. In this study, the response of occupancy probability of giant pandas against habitat patch size was studied in five of the six mountain ranges inhabited by giant panda, which cover over 78% of the global distribution of giant panda habitat. The probability of giant panda occurrence was positively associated with habitat patch area, and the observed increase in occupancy probability with patch size was higher than that due to passive sampling alone. These results suggest that the giant panda is an area-sensitive species. The MAR for giant panda was estimated to be 114.7 km 2 based on analysis of its occupancy probability. Giant panda habitats appear more fragmented in the three southern mountain ranges, while they are large and more continuous in the other two. Establishing corridors among habitat patches can mitigate habitat fragmentation, but expanding habitat patch sizes is necessary in mountain ranges where fragmentation is most intensive.
Anderson localization of shear waves observed by magnetic resonance imaging
NASA Astrophysics Data System (ADS)
Papazoglou, S.; Klatt, D.; Braun, J.; Sack, I.
2010-07-01
In this letter we present for the first time an experimental investigation of shear wave localization using motion-sensitive magnetic resonance imaging (MRI). Shear wave localization was studied in gel phantoms containing arrays of randomly positioned parallel glass rods. The phantoms were exposed to continuous harmonic vibrations in a frequency range from 25 to 175 Hz, yielding wavelengths on the order of the elastic mean free path, i.e. the Ioffe-Regel criterion of Anderson localization was satisfied. The experimental setup was further chosen such that purely shear horizontal waves were induced to avoid effects due to mode conversion and pressure waves. Analysis of the distribution of shear wave intensity in experiments and simulations revealed a significant deviation from Rayleigh statistics indicating that shear wave energy is localized. This observation is further supported by experiments on weakly scattering samples exhibiting Rayleigh statistics and an analysis of the multifractality of wave functions. Our results suggest that motion-sensitive MRI is a promising tool for studying Anderson localization of time-harmonic shear waves, which are increasingly used in dynamic elastography.
LaFond, Rebecca E.; Lukehart, Sheila A.
2006-01-01
Syphilis is a chronic sexually transmitted disease caused by Treponema pallidum subsp. pallidum. Clinical manifestations separate the disease into stages; late stages of disease are now uncommon compared to the preantibiotic era. T. pallidum has an unusually small genome and lacks genes that encode many metabolic functions and classical virulence factors. The organism is extremely sensitive to environmental conditions and has not been continuously cultivated in vitro. Nonetheless, T. pallidum is highly infectious and survives for decades in the untreated host. Early syphilis lesions result from the host's immune response to the treponemes. Bacterial clearance and resolution of early lesions results from a delayed hypersensitivity response, although some organisms escape to cause persistent infection. One factor contributing to T. pallidum's chronicity is the paucity of integral outer membrane proteins, rendering intact organisms virtually invisible to the immune system. Antigenic variation of TprK, a putative surface-exposed protein, is likely to contribute to immune evasion. T. pallidum remains exquisitely sensitive to penicillin, but macrolide resistance has recently been identified in a number of geographic regions. The development of a syphilis vaccine, thus far elusive, would have a significant positive impact on global health. PMID:16418521
STFT or CWT for the detection of Doppler ultrasound embolic signals.
Gonçalves, Ivo B; Leiria, Ana; Moura, M M M
2013-09-01
Aiming reliable detection and localization of cerebral blood flow and emboli, embolic signals were added to simulated middle cerebral artery Doppler signals and analysed. Short-time Fourier transform (STFT) and continuous wavelet transform (CWT) were used in the evaluation. The following parameters were used in this study: the powers of the embolic signals added were 5, 6, 6.5, 7, 7.5, 8 and 9 dB; the mother wavelets for CWT analysis were Morlet, Mexican hat, Meyer, Gaussian (order 4) and Daubechies (orders 4 and 8); and the thresholds for detection (equated in terms of false positive, false negative and sensitivity) were 2 and 3.5 dB for the CWT and STFT, respectively. The results indicate that although the STFT allows accurately detecting emboli, better time localization can be achieved with the CWT. Among the CWT, the current best overall results were obtained with Mexican Hat mother wavelet, with optimal results for sensitivity (100% detection rate) for nearly all emboli power values studied. Copyright © 2013 John Wiley & Sons, Ltd.
An Indoor Continuous Positioning Algorithm on the Move by Fusing Sensors and Wi-Fi on Smartphones
Li, Huaiyu; Chen, Xiuwan; Jing, Guifei; Wang, Yuan; Cao, Yanfeng; Li, Fei; Zhang, Xinlong; Xiao, Han
2015-01-01
Wi-Fi indoor positioning algorithms experience large positioning error and low stability when continuously positioning terminals that are on the move. This paper proposes a novel indoor continuous positioning algorithm that is on the move, fusing sensors and Wi-Fi on smartphones. The main innovative points include an improved Wi-Fi positioning algorithm and a novel positioning fusion algorithm named the Trust Chain Positioning Fusion (TCPF) algorithm. The improved Wi-Fi positioning algorithm was designed based on the properties of Wi-Fi signals on the move, which are found in a novel “quasi-dynamic” Wi-Fi signal experiment. The TCPF algorithm is proposed to realize the “process-level” fusion of Wi-Fi and Pedestrians Dead Reckoning (PDR) positioning, including three parts: trusted point determination, trust state and positioning fusion algorithm. An experiment is carried out for verification in a typical indoor environment, and the average positioning error on the move is 1.36 m, a decrease of 28.8% compared to an existing algorithm. The results show that the proposed algorithm can effectively reduce the influence caused by the unstable Wi-Fi signals, and improve the accuracy and stability of indoor continuous positioning on the move. PMID:26690447
NASA Astrophysics Data System (ADS)
Thompson, Kyle Bonner
An algorithm is described to efficiently compute aerothermodynamic design sensitivities using a decoupled variable set. In a conventional approach to computing design sensitivities for reacting flows, the species continuity equations are fully coupled to the conservation laws for momentum and energy. In this algorithm, the species continuity equations are solved separately from the mixture continuity, momentum, and total energy equations. This decoupling simplifies the implicit system, so that the flow solver can be made significantly more efficient, with very little penalty on overall scheme robustness. Most importantly, the computational cost of the point implicit relaxation is shown to scale linearly with the number of species for the decoupled system, whereas the fully coupled approach scales quadratically. Also, the decoupled method significantly reduces the cost in wall time and memory in comparison to the fully coupled approach. This decoupled approach for computing design sensitivities with the adjoint system is demonstrated for inviscid flow in chemical non-equilibrium around a re-entry vehicle with a retro-firing annular nozzle. The sensitivities of the surface temperature and mass flow rate through the nozzle plenum are computed with respect to plenum conditions and verified against sensitivities computed using a complex-variable finite-difference approach. The decoupled scheme significantly reduces the computational time and memory required to complete the optimization, making this an attractive method for high-fidelity design of hypersonic vehicles.
Sensitivity and Specificity of Histoplasma Antigen Detection by Enzyme Immunoassay.
Cunningham, Lauren; Cook, Audrey; Hanzlicek, Andrew; Harkin, Kenneth; Wheat, Joseph; Goad, Carla; Kirsch, Emily
2015-01-01
The objective of this study was to evaluate the sensitivity and specificity of an antigen enzyme immunoassay (EIA) on urine samples for the diagnosis of histoplasmosis in dogs. This retrospective medical records review included canine cases with urine samples submitted for Histoplasma EIA antigen assay between 2007 and 2011 from three veterinary institutions. Cases for which urine samples were submitted for Histoplasma antigen testing were reviewed and compared to the gold standard of finding Histoplasma organisms or an alternative diagnosis on cytology or histopathology. Sensitivity, specificity, negative predictive value, positive predictive value, and the kappa coefficient and associated confidence interval were calculated for the EIA-based Histoplasma antigen assay. Sixty cases met the inclusion criteria. Seventeen cases were considered true positives based on identification of the organism, and 41 cases were considered true negatives with an alternative definitive diagnosis. Two cases were considered false negatives, and there were no false positives. Sensitivity was 89.47% and the negative predictive value was 95.35%. Specificity and the positive predictive value were both 100%. The kappa coefficient was 0.9207 (95% confidence interval, 0.8131-1). The Histoplasma antigen EIA test demonstrated high specificity and sensitivity for the diagnosis of histoplasmosis in dogs.
Wardell, Jeffrey D.; Quilty, Lena C.; Hendershot, Christian S.
2017-01-01
Objective To examine impaired control over drinking behavior as a mediator of unique pathways from impulsive traits to alcohol outcomes in young adults and to investigate the moderating influence of self-reported sensitivity to alcohol on these pathways. Method Young adult heavy drinkers (N=172; n=82 women) recruited from the community completed self-report measures of impulsive traits (positive urgency, negative urgency, sensation seeking), alcohol sensitivity (Self-Rating of the Effects of Alcohol scale), impaired control over drinking, and alcohol use and problems. Multiple-groups path analysis was used to analyze the data. Results Path coefficients between urgency and impaired control were larger for individuals with lower versus higher self-reported sensitivity to alcohol. The same was true for the association between impaired control and alcohol problems. For participants lower on alcohol sensitivity, significant indirect paths were observed from both positive and negative urgency to all alcohol outcomes (quantity, frequency, and problems) mediated via impaired control. For participants higher on alcohol sensitivity, only the paths from negative urgency (but not positive urgency) to the three alcohol outcomes via impaired control were statistically significant. Sensation seeking was not uniquely associated with impaired control. Conclusions The findings indicate that relatively low sensitivity to the pharmacological effects of alcohol may exacerbate the association of urgency – especially positive urgency – with impaired control, supporting the notion that personality and level of response to alcohol may interact to increase risk for impaired control over drinking. PMID:25785803
Lee, Tzong-Hsi; Lin, Chien-Chu; Chung, Chen-Shuan; Lin, Cheng-Kuan; Liang, Cheng-Chao; Tsai, Kuang-Chau
2015-02-01
Previous studies demonstrated that the sensitivity of rapid urease test (RUT) for diagnosis of Helicobacter pylori infection decreased during peptic ulcer bleeding. We designed this study and tried to find a better method to improve the detection rate of H. pylori infection at the same session of endoscopic diagnosis of peptic ulcer bleeding. We prospectively enrolled 116 patients with peptic ulcer bleeding. These patients received intravenous proton pump inhibitor and then received upper gastrointestinal endoscopy within 24 h after arrival. We took one piece of biopsy from gastric antrum (Group 1), four pieces from gastric antrum (Group 2), and one piece from the gastric body (Group 3) for three separate RUTs, respectively. (13)C-urease breath test was used as gold standard for diagnosis of H. pylori infection. There were 74 patients (64 %) with positive (13)C-urease breath test. Among these 74 patients, 45 patients had positive RUT (sensitivity: 61 %) in Group 1; 55 patients had positive RUT (sensitivity: 74 %) in Group 2; 54 patients had positive RUT (sensitivity: 73 %) in Group 3. There were significant differences between Group 1 and Group 2 (p = 0.02) and between Group 1 and Group 3 (p = 0.022). The sensitivity of RUT was 61 % during peptic ulcer bleeding. The sensitivity of RUT can be increased significantly by increased biopsy number from gastric antrum or biopsy from gastric body.
Shrestha, Nabin K.; Tuohy, Marion J.; Padmanabhan, Ravindran A.; Hall, Gerri S.; Procop, Gary W.
2005-01-01
We evaluated the Roche LightCycler Staphylococcus MGRADE kits to differentiate between Staphylococcus aureus and coagulase-negative staphylococci in blood cultures growing clusters of gram-positive cocci. Testing 100 bottles (36 containing S. aureus), the assay was 100% sensitive and 98.44% specific for S. aureus and 100% sensitive and specific for coagulase-negative staphylococci. PMID:16333115
Shrestha, Nabin K; Tuohy, Marion J; Padmanabhan, Ravindran A; Hall, Gerri S; Procop, Gary W
2005-12-01
We evaluated the Roche LightCycler Staphylococcus M(GRADE) kits to differentiate between Staphylococcus aureus and coagulase-negative staphylococci in blood cultures growing clusters of gram-positive cocci. Testing 100 bottles (36 containing S. aureus), the assay was 100% sensitive and 98.44% specific for S. aureus and 100% sensitive and specific for coagulase-negative staphylococci.
Wichers, Marieke; Kenis, Gunter; Jacobs, Nele; Myin-Germeys, Inez; Schruers, Koen; Mengelers, Ron; Delespaul, Philippe; Derom, Catherine; Vlietinck, Robert; van Os, Jim
2008-08-01
Previous work indicated protective effects of positive emotions on genetically influenced stress sensitivity. Given the fact that expression of brain-derived-neurotrophic-factor (BDNF) is associated with stress-induced behavioral changes, it was hypothesized that the BDNF Val-sup-6-sup-6Met genotype may mediate genetic effects on stress sensitivity, conditional on the level of concurrent positive emotions. Subjects (n=446) participated in a momentary assessment study, collecting appraisals of stress and affect in the flow of daily life. Multilevel regression analyses examined moderation of daily life stress-induced negative affect (NA) by BDNF genotype, and to what degree this was conditional on concurrent positive emotions. Results showed that heterozygous BDNF "Met" carriers exhibited an increased NA response to social stress compared with "Val/Val" subjects. Positive emotions at the time of the stressor decreased BDNF genetic moderation of the NA response to social stress in a dose-response fashion. This effect was most pronounced in BDNF Met carriers. Thus, the impact of BDNF genotype on stress sensitivity is conditional on the experience of positive emotions. Interdisciplinary research in psychology and psychiatric genetics may lead to the improvement of treatment choices in stress-related disorders. Copyright (c) 2008 APA, all rights reserved.
32 CFR 154.14 - Civilian employment.
Code of Federal Regulations, 2013 CFR
2013-07-01
... investigation required is set forth in this section according to position sensitivity. (b) Nonsensitive... submitted to DIS by entering “SH” (summer hire) in red letters approximately one inch high on the DD Form...) of this section, regarding the type of investigation required by position sensitivity for DoD...
32 CFR 154.14 - Civilian employment.
Code of Federal Regulations, 2012 CFR
2012-07-01
... investigation required is set forth in this section according to position sensitivity. (b) Nonsensitive... submitted to DIS by entering “SH” (summer hire) in red letters approximately one inch high on the DD Form...) of this section, regarding the type of investigation required by position sensitivity for DoD...
32 CFR 154.14 - Civilian employment.
Code of Federal Regulations, 2011 CFR
2011-07-01
... investigation required is set forth in this section according to position sensitivity. (b) Nonsensitive... submitted to DIS by entering “SH” (summer hire) in red letters approximately one inch high on the DD Form...) of this section, regarding the type of investigation required by position sensitivity for DoD...
32 CFR 154.14 - Civilian employment.
Code of Federal Regulations, 2014 CFR
2014-07-01
... investigation required is set forth in this section according to position sensitivity. (b) Nonsensitive... submitted to DIS by entering “SH” (summer hire) in red letters approximately one inch high on the DD Form...) of this section, regarding the type of investigation required by position sensitivity for DoD...
Position sensitive radioactivity detection for gas and liquid chromatography
Cochran, Joseph L.; McCarthy, John F.; Palumbo, Anthony V.; Phelps, Tommy J.
2001-01-01
A method and apparatus are provided for the position sensitive detection of radioactivity in a fluid stream, particularly in the effluent fluid stream from a gas or liquid chromatographic instrument. The invention represents a significant advance in efficiency and cost reduction compared with current efforts.
Senthil Kumar, S; Suresh Babu, S S; Anand, P; Dheva Shantha Kumari, G
2012-06-01
The purpose of our study was to fabricate in-house web-camera based automatic continuous patient movement monitoring device and control the movement of the patients during EXRT. Web-camera based patient movement monitoring device consists of a computer, digital web-camera, mounting system, breaker circuit, speaker, and visual indicator. The computer is used to control and analyze the patient movement using indigenously developed software. The speaker and the visual indicator are placed in the console room to indicate the positional displacement of the patient. Studies were conducted on phantom and 150 patients with different types of cancers. Our preliminary clinical results indicate that our device is highly reliable and can accurately report smaller movements of the patients in all directions. The results demonstrated that the device was able to detect patient's movements with the sensitivity of about 1 mm. When a patient moves, the receiver activates the circuit; an audible warning sound will be produced in the console. Through real-time measurements, an audible alarm can alert the radiation technologist to stop the treatment if the user defined positional threshold is violated. Simultaneously, the electrical circuit to the teletherapy machine will be activated and radiation will be halted. Patient's movement during the course for radiotherapy was studied. The beam is halted automatically when the threshold level of the system is exceeded. By using the threshold provided in the system, it is possible to monitor the patient continuously with certain fixed limits. An additional benefit is that it has reduced the tension and stress of a treatment team associated with treating patients who are not immobilized. It also enables the technologists to do their work more efficiently, because they don't have to continuously monitor patients with as much scrutiny as was required. © 2012 American Association of Physicists in Medicine.
Armitage, N.; Hardcastle, J. D.; Amar, S. S.; Balfour, T. W.; Haynes, J.; James, P. D.
1985-01-01
Two faecal occult blood tests, a simple chemical test Haemoccult and an immunological test, Fecatwin Sensitive/Feca EIA, were offered to 3,225 asymptomatic individuals as screening for colorectal cancer. One thousand three hundred and four (44%) completed and returned the tests and of these 126 (9.7%) were found to be positive - Haemoccult 40 (3%) and Feca EIA 106 (8.1%). Five cancers (4 Dukes' Stage A, 1 Dukes' Stage C) and 23 adenomas greater than 1 cm were detected - rates of 3.8 per 1000 persons screened and 17.7 per 1000 persons screened respectively. Of the five cancers identified 5 were Feca EIA positive and 3 were Haemoccult positive. Of the 23 adenomas greater than 1 cm diameter identified, J1 were Feca EIA positive and 20 were Haemoccult positive. Seventy-eight Feca EIA positive subjects were investigated and no neoplastic disease was identified. Whilst this sensitive immunological test increases the yield of carcinomas, the high false positive rate makes it unsuitable for population screening for colorectal cancer in its present form. PMID:4005139
46 CFR 153.1002 - Special operating requirements for heat sensitive cargoes.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 5 2011-10-01 2011-10-01 false Special operating requirements for heat sensitive cargoes. 153.1002 Section 153.1002 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... MATERIALS Operations Special Cargo Procedures § 153.1002 Special operating requirements for heat sensitive...
46 CFR 153.1002 - Special operating requirements for heat sensitive cargoes.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Special operating requirements for heat sensitive cargoes. 153.1002 Section 153.1002 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... MATERIALS Operations Special Cargo Procedures § 153.1002 Special operating requirements for heat sensitive...
46 CFR 153.1002 - Special operating requirements for heat sensitive cargoes.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 5 2014-10-01 2014-10-01 false Special operating requirements for heat sensitive cargoes. 153.1002 Section 153.1002 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... MATERIALS Operations Special Cargo Procedures § 153.1002 Special operating requirements for heat sensitive...
46 CFR 153.1002 - Special operating requirements for heat sensitive cargoes.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 5 2013-10-01 2013-10-01 false Special operating requirements for heat sensitive cargoes. 153.1002 Section 153.1002 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... MATERIALS Operations Special Cargo Procedures § 153.1002 Special operating requirements for heat sensitive...
46 CFR 153.1002 - Special operating requirements for heat sensitive cargoes.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 5 2012-10-01 2012-10-01 false Special operating requirements for heat sensitive cargoes. 153.1002 Section 153.1002 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... MATERIALS Operations Special Cargo Procedures § 153.1002 Special operating requirements for heat sensitive...
Cui, Yong; Robinson, Jason D.; Engelmann, Jeffrey M.; Lam, Cho Y.; Minnix, Jennifer A.; Karam-Hage, Maher; Wetter, David W.; Dani, John A.; Kosten, Thomas R.; Cinciripini, Paul M.
2014-01-01
Nicotine dependence has been suggested to be related to reinforcement sensitivity, which encompasses behavioral predispositions either to avoid aversive (behavioral inhibition) or to approach appetitive (behavioral activation) stimuli. Reinforcement sensitivity may shape motives for nicotine use and offer potential targets for personalized smoking cessation therapy. However, little is known regarding how reinforcement sensitivity is related to motivational processes implicated in the maintenance of smoking. Additionally, women and men differ in reinforcement sensitivity, and such difference may cause distinct relationships between reinforcement sensitivity and motivational processes for female and male smokers. In this study, we characterized reinforcement sensitivity in relation to affect, smoking-related reinforcement motives, and affective responses, using self-report and psychophysiological measures, in over 200 smokers before treating them. The Behavioral Inhibition/Activation Scales (BIS/BAS; Carver & White, 1994) was used to measure reinforcement sensitivity. In female and male smokers, BIS was similarly associated with negative affect and negative reinforcement of smoking. But positive affect was positively associated with BAS Drive scores in male smokers, and this association was reversed in female smokers. BIS was positively associated with corrugator electromyographic reactivity towards negative stimuli and left frontal electroencephalogram alpha asymmetry. Female and male smokers showed similar relationships for these physiological measures. These findings suggest that reinforcement sensitivity underpins important motivational processes (e.g., affect), and gender is a moderating factor for these relationships. Future personalized smoking intervention, particularly among more dependent treatment-seeking smokers, may experiment to target individual differences in reinforcement sensitivity. PMID:25621416
Compliance and stress sensitivity of spur gear teeth
NASA Technical Reports Server (NTRS)
Cornell, R. W.
1983-01-01
The magnitude and variation of tooth pair compliance with load position affects the dynamics and loading significantly, and the tooth root stressing per load varies significantly with load position. Therefore, the recently developed time history, interactive, closed form solution for the dynamic tooth loads for both low and high contact ratio spur gears was expanded to include improved and simplified methods for calculating the compliance and stress sensitivity for three involute tooth forms as a function of load position. The compliance analysis has an improved fillet/foundation. The stress sensitivity analysis is a modified version of the Heywood method but with an improvement in the magnitude and location of the peak stress in the fillet. These improved compliance and stress sensitivity analyses are presented along with their evaluation using test, finite element, and analytic transformation results, which showed good agreement.
Majewski, Stanislaw; Weisenberger, Andrew G.
2004-06-15
In a camera or similar radiation sensitive device comprising a pixilated scintillation layer, a light guide and an array of position sensitive photomultiplier tubes, wherein there exists so-called dead space between adjacent photomultiplier tubes the improvement comprising a two part light guide comprising a first planar light spreading layer or portion having a first surface that addresses the scintillation layer and optically coupled thereto at a second surface that addresses the photomultiplier tubes, a second layer or portion comprising an array of trapezoidal light collectors defining gaps that span said dead space and are individually optically coupled to individual position sensitive photomultiplier tubes. According to a preferred embodiment, coupling of the trapezoidal light collectors to the position sensitive photomultiplier tubes is accomplished using an optical grease having about the same refractive index as the material of construction of the two part light guide.
Kodani, Maja; Mixson-Hayden, Tonya; Drobeniuc, Jan; Kamili, Saleem
2014-10-01
Five viruses have been etiologically associated with viral hepatitis. Nucleic acid testing (NAT) remains the gold standard for diagnosis of viremic stages of infection. NAT methodologies have been developed for all hepatitis viruses; however, a NAT-based assay that can simultaneously detect all five viruses is not available. We designed TaqMan card-based assays for detection of HAV RNA, HBV DNA, HCV RNA, HDV RNA and HEV RNA. The performances of individual assays were evaluated on TaqMan Array Cards (TAC) for detecting five viral genomes simultaneously. Sensitivity and specificity were determined by testing 329 NAT-tested clinical specimens. All NAT-positive samples for HCV (n = 32), HDV (n = 28) and HEV (n = 14) were also found positive in TAC (sensitivity, 100%). Forty-three of 46 HAV-NAT positive samples were also positive in TAC (sensitivity, 94%), while 36 of 39 HBV-NAT positive samples were positive (sensitivity, 92%). No false-positives were detected for HBV (n = 32), HCV (n = 36), HDV (n = 30), and HEV (n = 31) NAT-negative samples (specificity 100%), while 38 of 41 HAV-NAT negative samples were negative by TAC (specificity 93%). TAC assay was concordant with corresponding individual NATs for hepatitis A-E viral genomes and can be used for their detection simultaneously. The TAC assay has potential for use in hepatitis surveillance, for screening of donor specimens and in outbreak situations. Wider availability of TAC-ready assays may allow for customized assays, for improving acute jaundice surveillance and for other purposes for which there is need to identify multiple pathogens rapidly. Published by Elsevier B.V.
Diagnosing periprosthetic infection: false-positive intraoperative Gram stains.
Oethinger, Margret; Warner, Debra K; Schindler, Susan A; Kobayashi, Hideo; Bauer, Thomas W
2011-04-01
Intraoperative Gram stains have a reported low sensitivity but high specificity when used to help diagnose periprosthetic infections. In early 2008, we recognized an unexpectedly high frequency of apparent false-positive Gram stains from revision arthroplasties. The purpose of this report is to describe the cause of these false-positive test results. We calculated the sensitivity and specificity of all intraoperative Gram stains submitted from revision arthroplasty cases during a 3-month interval using microbiologic cultures of the same samples as the gold standard. Methods of specimen harvesting, handling, transport, distribution, specimen processing including tissue grinding/macerating, Gram staining, and interpretation were studied. After a test modification, results of specimens were prospectively collected for a second 3-month interval, and the sensitivity and specificity of intraoperative Gram stains were calculated. The retrospective review of 269 Gram stains submitted from revision arthroplasties indicated historic sensitivity and specificity values of 23% and 92%, respectively. Systematic analysis of all steps of the procedure identified Gram-stained but nonviable bacteria in commercial broth reagents used as diluents for maceration of periprosthetic membranes before Gram staining and culture. Polymerase chain reaction and sequencing showed mixed bacterial DNA. Evaluation of 390 specimens after initiating standardized Millipore filtering of diluent fluid revealed a reduced number of positive Gram stains, yielding 9% sensitivity and 99% specificity. Clusters of false-positive Gram stains have been reported in other clinical conditions. They are apparently rare related to diagnosing periprosthetic infections but have severe consequences if used to guide treatment. Even occasional false-positive Gram stains should prompt review of laboratory methods. Our observations implicate dead bacteria in microbiologic reagents as potential sources of false-positive Gram stains.
Singh, Sarman; Singh, Amit; Prajapati, Suneel; Kabra, Sushil K; Lodha, Rakesh; Mukherjee, Aparna; Singh, Varinder; Hesseling, Anneke C; Grewal, Harleen M S
2015-09-29
Tuberculosis (TB) in children is neglected, mainly due to lack of sensitive diagnostic tools. Recently Xpert MTB/RIF assay has revolutionized the diagnostic field, but its usefulness in pediatric TB has not been reported from India and no report is available on its use on long term archived samples. We recruited 130 pediatric patients with probable intrathoracic tuberculosis and their gastric aspirate (GA) and induced sputum (IS) samples on 2 consecutive days were collected between January 2009 and December 2012. All samples (n = 520) were subjected to smear examination, BACTEC-MGIT culture and in-house multiplex PCR. An aliquot of each sample was stored at -80 °C and tested in Xpert MTB/RIF assay in 2013. Sample wise and patient wise detection rate of smear microscopy was 4.4 % and 10 %, while for BACTEC-MGIT culture this rate was 24.4 % and 46.9 %, respectively. Of the 130 day 1 GA samples, 31.5 % and 27.7 % day 2 GA samples were culture positive. Only 17.7 % GA samples were positive on both days. Of the 130 IS samples collected on day 1 and day 2, 15.4 % and 23.1 % samples were culture positive. A combination of GA and IS yielded best results. Combining both GA and IS, the overall sensitivity of Xpert MTB/RIF on smear and culture positive samples was 95.6 %. In smear negative and culture positive samples its sensitivity was 62.5 %. The duration of sample storage impacted the Xpert MTB/RIF test performance (p = 0.0001). In smear positive samples stored for 650-849 days, its sensitivity was 85.7 % and 77.1 % for IS and GA samples which dropped to 33.3 % and 50 %, respectively, if stored for more than 1050 days. Confirmatory diagnosis of tuberculosis particularly in children is a medical challenge. No laboratory or radiological test can reach to a satisfactory level of diagnostic sensitivity. However, in this study we found that combination of multiple samples and multiple diagnostic tests can give much better yield, though not optimum. In present study, combination of 2 gastric aspirates (GA) and 2 induced sputum (IS) samples collected on two consecutive days, and tested on three diagnostic methods yielded a significantly high detection rate. Despite long term storage, the overall sensitivity of Xpert MTB/RIF on smear and -culture positive samples remained very high. But after storing these samples under subfreezing conditions the sensitivity of Xpert MTB/RIF decreased significantly. This is expected because even if the sample is smear and culture positive, the count of surviving mycobacteria goes down, after several years this count can reach to a undetectable level. This report shows that smear and culture positive samples stored at subfreezing conditions for several years can be used in the Xpert MTB/RIF assay, while maintaining appreciable diagnostic test sensitivity and specificity.
Development of Position-Sensitive Magnetic Calorimeters for X-Ray Astronomy
NASA Technical Reports Server (NTRS)
Bandler, SImon; Stevenson, Thomas; Hsieh, Wen-Ting
2011-01-01
Metallic magnetic calorimeters (MMC) are one of the most promising devices to provide very high energy resolution needed for future astronomical x-ray spectroscopy. MMC detectors can be built to large detector arrays having thousands of pixels. Position-sensitive magnetic (PoSM) microcalorimeters consist of multiple absorbers thermally coupled to one magnetic micro calorimeter. Each absorber element has a different thermal coupling to the MMC, resulting in a distribution of different pulse shapes and enabling position discrimination between the absorber elements. PoSMs therefore achieve the large focal plane area with fewer number of readout channels without compromising spatial sampling. Excellent performance of PoSMs was achieved by optimizing the designs of key parameters such as the thermal conductance among the absorbers, magnetic sensor, and heat sink, as well as the absorber heat capacities. Micro fab ri - cation techniques were developed to construct four-absorber PoSMs, in which each absorber consists of a two-layer composite of bismuth and gold. The energy resolution (FWHM full width at half maximum) was measured to be better than 5 eV at 6 keV x-rays for all four absorbers. Position determination was demonstrated with pulse-shape discrimination, as well as with pulse rise time. X-ray microcalorimeters are usually designed to thermalize as quickly as possible to avoid degradation in energy resolution from position dependence to the pulse shapes. Each pixel consists of an absorber and a temperature sensor, both decoupled from the cold bath through a weak thermal link. Each pixel requires a separate readout channel; for instance, with a SQUID (superconducting quantum interference device). For future astronomy missions where thousands to millions of resolution elements are required, having an individual SQUID readout channel for each pixel becomes difficult. One route to attaining these goals is a position-sensitive detector in which a large continuous or pixilated array of x-ray absorbers shares fewer numbers of temperature sensors. A means of discriminating the signals from different absorber positions, however, needs to be built into the device for each sensor. The design concept for the device is such that the shape of the temperature pulse with time depends on the location of the absorber. This inherent position sensitivity of the signal is then analyzed to determine the location of the event precisely, effectively yielding one device with many sub-pixels. With such devices, the total number of electronic channels required to read out a given number of pixels is significantly reduced. PoSMs were developed that consist of four discrete absorbers connected to a single magnetic sensor. The design concept can be extended to more than four absorbers per sensor. The thermal conductance between the sensor and each absorber is different by design and consequently, the pulse shapes are different depending upon which absorber the xrays are received, allowing position discrimination. A magnetic sensor was used in which a paramagnetic Au:Er temperature-sensitive material is located in a weak magnetic field. Deposition of energy from an x-ray photon causes an increase in temperature, which leads to a change of magnetization of the paramagnetic sensor, which is subsequently read out using a low noise dc-SQUID. The PoSM microcalorimeters are fully microfabricated: the Au:Er sensor is located above the meander, with a thin insulation gap in between. For this position-sensitive device, four electroplated absorbers are thermally linked to the sensor via heat links of different thermal conductance. One pixel is identical to that of a single-pixel design, consisting of an overhanging absorber fabricated directly on top of the sensor. It is therefore very strongly thermally coupled to it. The three other absorbers are supported directly on a silicon-nitride membrane. These absorbers are thermally coupled to the sensor via Ti (5 nm)/Au250 nm) metal links. The strength of the links is parameterized by the number of gold squares making up the link. For detector performance, experimentally different pulse-shapes were demonstrated with 6 keV x-rays, which clearly show different rise times for different absorber positions. For energy resolution measurement, the PoSM was operated at 32 mK with an applied field that was generated using a persistent current of 50 mA. Over the four pixels, energy resolution ranges from 4.4 to 4.7 eV were demonstrated.
Paul, Rudrajit; Ghosh, Asim K; Nag, Adwaita; Biswas, Shyamapada; Naiya, Britisundar; Mondal, Jayati
2017-06-01
Measurement of Retinal Nerve Fibre Layer Thickness (RNFLT) by Optical Coherence Tomography (OCT) is a sensitive, non invasive and cheap method of detecting early retinal changes in a variety of diseases. In HIV infection, RNFLT is altered and this may have effect on other visual functions like Contrast Sensitivity (CS) and visual acuity. Such ocular pathology can affect the daily life and profession (especially driving) of HIV infected individuals. However, studies on this topic in HIV infected population are rare from India. To study RNFLT, CS and their correlation in a sample of HIV positive Indian population. The present cross-sectional study was done in a tertiary care medical college hospital of Eastern India between May 2016 and September 2016. We did this study on HIV positive subjects with no clinically apparent ocular infection or other pathology. In this study, we have measured the RNFLT using the HRA-OCT Spectralis machine. The CS was tested using a smartphone version of the Pellie-Robson chart. CD4 count, visual acuity and colour vision were also tested. The data was analysed using SPSS version 20.0 for any correlation between these parameters. Pearson coefficient was used for continuous data and Spearman rank correlation was used for categorical data. A p-value <0.05 was considered significant. We had 17 patients, that is 34 eyes. RNFLT loss was found in 21% of the eyes and borderline thinning was found in a further 26%. Predominantly, the temporal quadrant was involved. The mean of log CS was 1.33±0.38. Taking 1.5 as the cut-off value for normalcy, 47% of the eyes tested showed decreased CS. Log CS showed significant correlation with RNFLT of the temporal quadrant only (r=0.37; 95% C.I. 0.041 to 0.631; p=0.02). Temporal RNFLT also showed statistical correlation with the CD4 count. The low CS was also significantly correlated with low visual acuity (r=0.5). In HIV infected persons, subtle ocular changes may occur and this may affect visual functions quite early. Hence, a comprehensive eye check-up should include parameters like CS and OCT.
NASA Astrophysics Data System (ADS)
Rabatel, Matthias; Rampal, Pierre; Carrassi, Alberto; Bertino, Laurent; Jones, Christopher K. R. T.
2018-03-01
We present a sensitivity analysis and discuss the probabilistic forecast capabilities of the novel sea ice model neXtSIM used in hindcast mode. The study pertains to the response of the model to the uncertainty on winds using probabilistic forecasts of ice trajectories. neXtSIM is a continuous Lagrangian numerical model that uses an elasto-brittle rheology to simulate the ice response to external forces. The sensitivity analysis is based on a Monte Carlo sampling of 12 members. The response of the model to the uncertainties is evaluated in terms of simulated ice drift distances from their initial positions, and from the mean position of the ensemble, over the mid-term forecast horizon of 10 days. The simulated ice drift is decomposed into advective and diffusive parts that are characterised separately both spatially and temporally and compared to what is obtained with a free-drift model, that is, when the ice rheology does not play any role in the modelled physics of the ice. The seasonal variability of the model sensitivity is presented and shows the role of the ice compactness and rheology in the ice drift response at both local and regional scales in the Arctic. Indeed, the ice drift simulated by neXtSIM in summer is close to the one obtained with the free-drift model, while the more compact and solid ice pack shows a significantly different mechanical and drift behaviour in winter. For the winter period analysed in this study, we also show that, in contrast to the free-drift model, neXtSIM reproduces the sea ice Lagrangian diffusion regimes as found from observed trajectories. The forecast capability of neXtSIM is also evaluated using a large set of real buoy's trajectories and compared to the capability of the free-drift model. We found that neXtSIM performs significantly better in simulating sea ice drift, both in terms of forecast error and as a tool to assist search and rescue operations, although the sources of uncertainties assumed for the present experiment are not sufficient for complete coverage of the observed IABP positions.
Gibson, Lauren E; Anglin, Deidre M; Klugman, Joshua T; Reeves, Lauren E; Fineberg, Anna M; Maxwell, Seth D; Kerns, Connor M; Ellman, Lauren M
2014-06-01
The purpose of this study was to investigate whether stress sensitivity mediates the relationship between traumatic life events and total attenuated positive psychotic symptoms, as well as the relationship between traumatic life events and endorsement of 8 or more attenuated positive psychotic symptoms as distressing (a threshold that has been associated with higher risk for psychosis in clinical groups). Participants (n = 671, aged 17-35, 29% male) were college students who were administered the Prodromal Questionnaire, the Perceived Stress Scale and the Life Events Checklist. Bootstrapping results indicated that stress sensitivity significantly mediated the relationships between traumatic life events and the number of attenuated positive psychotic symptoms endorsed and between traumatic life events and those who endorsed 8 or more distressing attenuated positive psychotic symptoms. Stratified gender analyses indicated the findings were specific to females. Results suggest that stress sensitivity may represent a specific vulnerability factor for risk of attenuated psychotic symptoms in those previously exposed to traumatic life events and that this liability appears stronger in females. Copyright © 2014 Elsevier Ltd. All rights reserved.
1987-09-01
accuracy. The data aquisition system combines a position- sensitive X-ray detector with a 65 kilobyte microcomputer capable of operating as a...The rapid X-ray diffraction system measures intensity versus 20 patterns by placing the detector with its sensitivity axis positioned parallel to the...plane of the diffractometer (see Figure 2). As shown in Figure 2, the detector sensitivity axis z is coplanar with both the incident beam and the
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-18
... OFFICE OF PERSONNEL MANAGEMENT Submission for Review: Information Collection; Questionnaire for... collection request (ICR), Office of Management and Budget (OMB) Control No. 3206-NEW, for Questionnaire for... Questionnaire for Non-Sensitive Positions, SF 85, housed in a system named e-QIP (Electronic Questionnaires for...
Characteristics of atmospheric transport into the Antarctic troposphere
NASA Astrophysics Data System (ADS)
Stohl, A.; Sodemann, H.
2010-01-01
We have developed a 5.5 year climatology of atmospheric transport into the Antarctic troposphere, which uses the same data set and methods as described in a recent study for the Arctic. This allows direct comparisons of transport properties for the two polar regions. The climatology is based on a simulation with the Lagrangian particle dispersion model FLEXPART, where the model atmosphere was globally filled with particles. Transport characteristics as well as emission sensitivities were derived from 6 hourly particle positions. We found that the probability for near-surface air to originate from the stratosphere on a time scale of 10 days is an order of magnitude higher near the South Pole than near the North Pole, a result of higher topography and descent that partly compensates for the flow of air down the Antarctic Plateau with the katabatic winds. The stratospheric influence is largest in fall, which is opposite to the seasonality in the Arctic. Stratospheric influence is much smaller over the shelf ice regions and in a band around Antarctica. The average time for which air near the surface has been exposed to continuous darkness in July (continuous light in January) is longest over the Ronne Ice Shelf and Ross Ice Shelf at ˜11 days (20 days). We calculated how sensitive Antarctic air masses are to emission input up to 30 days before arriving in Antarctica if removal processes are ignored. The emission sensitivity shows strong meridional gradients and, as a result, is generally low over South America, Africa, and Australia. For a 10 day time scale, the largest emission sensitivities over these continents are 1-2 orders of magnitude smaller than over Eurasia for transport to the Arctic, showing that foreign continents have a much smaller potential to pollute the Antarctic than the Arctic troposphere. Emission sensitivities and derived black carbon (BC) source contributions over South America, Africa, and Australia are substantially (a factor 10 for Africa) larger in winter than in summer. In winter, biomass burning contributes more BC than anthropogenic sources. For typical aerosol lifetimes of 5-10 days, ship emissions south of 60°S account for half of the total BC concentrations in the lowest 1000 m of the atmosphere south of 70°S in December. The increasing number of tourists visiting Antarctica and fishing vessels operating close to Antarctica are, therefore, a matter of concern.
Physiological and Thermal Responses of MS Patients to Head and Vest Cooling: A Case Study
NASA Technical Reports Server (NTRS)
Luna, Bernadette; Webbon, Bruce W.; Ku, Yu-Tsuan E.; Lee, Hank C.; Montgomery, Leslie D.; Kliss, Mark (Technical Monitor)
1997-01-01
Personal cooling systems are used to alleviate symptoms of multiple sclerosis (MS) and to prevent increased core temperature during daily activities. The objective of this study was to determine the operating characteristics and the physiologic changes produced by short term application of the stationary thermal control system used by most clinical institutions. The Life Enhancement Tech (LET) Mark VII portable cooling system and a lightweight Head-vest active cooling garment were used to cool the head and chest regions of 4 male and 3 female MS patients (30 to 66 yrs. old) in this study. The subjects, seated in an upright position at normal room temperature (approx. 24 C), were tested for 60 min. with the liquid cooling garment (LCG) operated at 50 F. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures, heart rate, respiration, and an activity index were recorded continuously on a U.F.I., Inc., Biolog ambulatory monitor. All temperature responses showed extreme variation among subjects. The cold-sensitive subject's rectal temperature increased initially in response to cooling; the heat sensitive subject's rectal temperature decreased. After 40 min. of cooling and during recovery, all subjects'rectal temperatures decreased. Oral temperatures began to decrease after 30 min. of cooling. After 60 min. of cooling, temperature drops ranged from approx. 0.3 - 0.8 C. Oral temperatures continued to decrease during recovery (approx. 0.2 C). The car temperature of the heat sensitive subject was increased after cooling, other subjects exhibited an ear temperature decrease (0.0 - 0.5 C). These data indicate that head and vest cooling may be used to reduce the oral temperatures of MS patients by the approximate amount needed for symptomatic relief as shown by other researchers. The combination of a small subject population and a large subject variance does not permit us to draw statistical conclusions about the temperature response of MS patients. An individual's heat or cold sensitivity may influence their thermal response to cooling. This factor should be considered in the prescribed use of liquid cooling garments in the therapeutic management of MS.
75 FR 14628 - Pressure Sensitive Plastic Tape From Italy; Determination
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-26
... Plastic Tape From Italy; Determination On the basis of the record \\1\\ developed in the subject five-year... pressure sensitive plastic tape from Italy would be likely to lead to continuation or recurrence of... Publication 4128 (March 2010), entitled Pressure Sensitive Plastic Tape from Italy: Investigation No. AA1921...
Improvement of immunoassay detection system by using alternating current magnetic susceptibility
NASA Astrophysics Data System (ADS)
Kawabata, R.; Mizoguchi, T.; Kandori, A.
2016-03-01
A major goal with this research was to develop a low-cost and highly sensitive immunoassay detection system by using alternating current (AC) magnetic susceptibility. We fabricated an improved prototype of our previously developed immunoassay detection system and evaluated its performance. The prototype continuously moved sample containers by using a magnetically shielded brushless motor, which passes between two anisotropic magneto resistance (AMR) sensors. These sensors detected the magnetic signal in the direction where each sample container passed them. We used the differential signal obtained from each AMR sensor's output to improve the signal-to-noise ratio (SNR) of the magnetic signal measurement. Biotin-conjugated polymer beads with avidin-coated magnetic particles were prepared to examine the calibration curve, which represents the relation between AC magnetic susceptibility change and polymer-bead concentration. For the calibration curve measurement, we, respectively, measured the magnetic signal caused by the magnetic particles by using each AMR sensor installed near the upper or lower part in the lateral position of the passing sample containers. As a result, the SNR of the prototype was 4.5 times better than that of our previous system. Moreover, the data obtained from each AMR sensor installed near the upper part in the lateral position of the passing sample containers exhibited an accurate calibration curve that represented good correlation between AC magnetic susceptibility change and polymer-bead concentration. The conclusion drawn from these findings is that our improved immunoassay detection system will enable a low-cost and highly sensitive immunoassay.
Sayyahfar, Shirin; Fahimzad, Alireza; Naddaf, Amir; Tavassoli, Sara
2015-12-01
The aim of this study was to evaluate the antibiotic susceptibility of Group A streptococcus (GAS) to antibiotics usually used in Iran for treatment of GAS pharyngitis in children. From 2011 to 2013, children 3-15 years of age with acute tonsillopharyngitis who attended Mofid Children's Hospital clinics and emergency ward and did not meet the exclusion criteria were enrolled in a prospective study in a sequential manner. The isolates strains from throat culture were identified as GAS by colony morphology, gram staining, beta hemolysis on blood agar, sensitivity to bacitracin, a positive pyrrolidonyl aminopeptidase (PYR) test result, and the presence of Lancefield A antigen determined by agglutination test. Antimicrobial susceptibility was identified by both disk diffusion and broth dilution methods. From 200 children enrolled in this study, 59 (30%) cases were culture positive for GAS. All isolates were sensitive to penicillin G. The prevalence of erythromycin, azithromycin, and clarithromycin resistance by broth dilution method was 33.9%, 57.6%, and 33.9%, respectively. Surprisingly, 8.4% of GAS strains were resistant to rifampin. In this study, 13.5% and 32.2% of the strains were resistant to clindamycin and ofloxacin, respectively. The high rate of resistance of GAS to some antibiotics in this study should warn physicians, especially in Iran, to use antibiotics restrictedly and logically to prevent the rising of resistance rates in future. It also seems that continuous local surveillance is necessary to achieve the best therapeutic option for GAS treatment.
Anxiety Sensitivity and Cannabis Use-Related Problems: The Impact of Race
Dean, Kimberlye E.; Ecker, Anthony H.; Buckner, Julia D.
2017-01-01
Background and Objectives Cannabis is the most widely used illicit substance among young adults. Anxiety sensitivity (AS; i.e., fear of anxiety-related symptoms) is positively related to coping motives for cannabis use (which are robustly positively linked to cannabis-related problems). However, AS is unrelated to cannabis use-related problems. Yet, extant studies have been conducted on primarily White samples. It may be that among Black students, AS-physical concerns (i.e., fear of physical anxiety-related sensations) are related to cannabis problems given that Black individuals are more likely than White individuals to report experiencing greater and more intense somatic symptoms when experiencing anxiety. Black individuals may rely on cannabis to cope with fear of these somatic symptoms, continuing to use despite cannabis-related problems. Methods The current study tested whether race moderated the relation between AS-physical concerns and cannabis problems among 102 (85.3% female) current cannabis using undergraduates who were either non-Hispanic Black (n= 51) or non-Hispanic White (n= 51). Results After controlling for frequency of cannabis use, income, and gender, race significantly moderated the relation between AS-physical concerns and cannabis use-related problems such that AS-physical concerns significantly predicted cannabis-related problems among Black and not White individuals. Discussion and Conclusions Findings highlight the importance of considering race in identifying psychosocial predictors of cannabis-related problems. Scientific Significance Intervention strategies for Black cannabis users may benefit from examining and targeting AS-physical concerns. PMID:28295843
Anxiety sensitivity and cannabis use-related problems: The impact of race.
Dean, Kimberlye E; Ecker, Anthony H; Buckner, Julia D
2017-04-01
Cannabis is the most widely used illicit substance among young adults. Anxiety sensitivity (AS; ie, fear of anxiety-related symptoms) is positively related to coping motives for cannabis use (which are robustly positively linked to cannabis-related problems). However, AS is unrelated to cannabis use-related problems. Yet, extant studies have been conducted on primarily White samples. It may be that among Black students, AS-physical concerns (ie, fear of physical anxiety-related sensations) are related to cannabis problems given that Black individuals are more likely than White individuals to report experiencing greater and more intense somatic symptoms when experiencing anxiety. Black individuals may rely on cannabis to cope with fear of these somatic symptoms, continuing to use despite cannabis-related problems. The current study tested whether race moderated the relation between AS-physical concerns and cannabis problems among 102 (85.3% female) current cannabis using undergraduates who were either non-Hispanic Black (n = 51) or non-Hispanic White (n = 51). After controlling for frequency of cannabis use, income, and gender, race significantly moderated the relation between AS-physical concerns and cannabis use-related problems such that AS-physical concerns significantly predicted cannabis-related problems among Black and not White individuals. Findings highlight the importance of considering race in identifying psychosocial predictors of cannabis-related problems. Intervention strategies for Black cannabis users may benefit from examining and targeting AS-physical concerns. (Am J Addict 2017;26:209-214). © 2017 American Academy of Addiction Psychiatry.
Improvement of immunoassay detection system by using alternating current magnetic susceptibility.
Kawabata, R; Mizoguchi, T; Kandori, A
2016-03-01
A major goal with this research was to develop a low-cost and highly sensitive immunoassay detection system by using alternating current (AC) magnetic susceptibility. We fabricated an improved prototype of our previously developed immunoassay detection system and evaluated its performance. The prototype continuously moved sample containers by using a magnetically shielded brushless motor, which passes between two anisotropic magneto resistance (AMR) sensors. These sensors detected the magnetic signal in the direction where each sample container passed them. We used the differential signal obtained from each AMR sensor's output to improve the signal-to-noise ratio (SNR) of the magnetic signal measurement. Biotin-conjugated polymer beads with avidin-coated magnetic particles were prepared to examine the calibration curve, which represents the relation between AC magnetic susceptibility change and polymer-bead concentration. For the calibration curve measurement, we, respectively, measured the magnetic signal caused by the magnetic particles by using each AMR sensor installed near the upper or lower part in the lateral position of the passing sample containers. As a result, the SNR of the prototype was 4.5 times better than that of our previous system. Moreover, the data obtained from each AMR sensor installed near the upper part in the lateral position of the passing sample containers exhibited an accurate calibration curve that represented good correlation between AC magnetic susceptibility change and polymer-bead concentration. The conclusion drawn from these findings is that our improved immunoassay detection system will enable a low-cost and highly sensitive immunoassay.
Design and performance tests of the calorimetric tract of a Compton Camera for small-animals imaging
NASA Astrophysics Data System (ADS)
Rossi, P.; Baldazzi, G.; Battistella, A.; Bello, M.; Bollini, D.; Bonvicini, V.; Fontana, C. L.; Gennaro, G.; Moschini, G.; Navarria, F.; Rashevsky, A.; Uzunov, N.; Zampa, G.; Zampa, N.; Vacchi, A.
2011-02-01
The bio-distribution and targeting capability of pharmaceuticals may be assessed in small animals by imaging gamma-rays emitted from radio-isotope markers. Detectors that exploit the Compton concept allow higher gamma-ray efficiency compared to conventional Anger cameras employing collimators, and feature sub-millimeter spatial resolution and compact geometry. We are developing a Compton Camera that has to address several requirements: the high rates typical of the Compton concept; detection of gamma-rays of different energies that may range from 140 keV ( 99 mTc) to 511 keV ( β+ emitters); presence of gamma and beta radiation with energies up to 2 MeV in case of 188Re. The camera consists of a thin position-sensitive Tracker that scatters the gamma ray, and a second position-sensitive detection system to totally absorb the energy of the scattered photons (Calorimeter). In this paper we present the design and discuss the realization of the calorimetric tract, including the choice of scintillator crystal, pixel size, and detector geometry. Simulations of the gamma-ray trajectories from source to detectors have helped to assess the accuracy of the system and decide on camera design. Crystals of different materials, such as LaBr 3 GSO and YAP, and of different size, in continuous or segmented geometry, have been optically coupled to a multi-anode Hamamatsu H8500 detector, allowing measurements of spatial resolution and efficiency.
Braga, G W; Bordin, J O; Moreira Júnior, G; Kuroda, A
1998-01-01
The direct manual Polybrene test (DPT) and the direct antiglobulin tests (DAT) were employed to detect antibody sensitizing red blood cell (RCB) in patients with clinical and laboratorial findings of autoimmune hemolytic anemia (AIHA). To compare the sensitivity and specificity of DPT and DAT in the diagnosis of AIHA. Eighteen consecutive patients with diagnosis of AIHA were evaluated. The control group consisted of 20 normal volunteers blood donors and 20 patients with sickle cell anemia. All patients and controls were submitted to DPT and DAT. All DAT positive samples were further tested using monospecific reagents (anti-IgG heavy chain and anti-C3d). Positive samples for either DPT or DAT were evaluated by eluate technique using. The dichloromethane (DCM). The DAT was positive in 14 patients and negative in 4 subjects, while the DPT was positive in 17 patients and negative in 1 individual who had a positive DAT owing to complement (C3d). All positive eluates performed with DCM showed RBC autoantibodies with presumed "anti-Rh" specificity. The sensitivity rate of the DPT (94%) was significantly (p < 0.05) higher than the sensitivity rate of DAT (78%) to determine whether IgG was bound in vivo, but no difference was found regarding the specificity of the two tests. 1) The DPT is more sensitive than the DAT in detecting IgG autoantibody on the RBCs of patients with AIHA; 2) because of its simplicity and rapidity, the DPT is a useful additional screening test for the investigation of Coombs-negative AIHA.
Wavelet method for CT colonography computer-aided polyp detection.
Li, Jiang; Van Uitert, Robert; Yao, Jianhua; Petrick, Nicholas; Franaszek, Marek; Huang, Adam; Summers, Ronald M
2008-08-01
Computed tomographic colonography (CTC) computer aided detection (CAD) is a new method to detect colon polyps. Colonic polyps are abnormal growths that may become cancerous. Detection and removal of colonic polyps, particularly larger ones, has been shown to reduce the incidence of colorectal cancer. While high sensitivities and low false positive rates are consistently achieved for the detection of polyps sized 1 cm or larger, lower sensitivities and higher false positive rates occur when the goal of CAD is to identify "medium"-sized polyps, 6-9 mm in diameter. Such medium-sized polyps may be important for clinical patient management. We have developed a wavelet-based postprocessor to reduce false positives for this polyp size range. We applied the wavelet-based postprocessor to CTC CAD findings from 44 patients in whom 45 polyps with sizes of 6-9 mm were found at segmentally unblinded optical colonoscopy and visible on retrospective review of the CT colonography images. Prior to the application of the wavelet-based postprocessor, the CTC CAD system detected 33 of the polyps (sensitivity 73.33%) with 12.4 false positives per patient, a sensitivity comparable to that of expert radiologists. Fourfold cross validation with 5000 bootstraps showed that the wavelet-based postprocessor could reduce the false positives by 56.61% (p <0.001), to 5.38 per patient (95% confidence interval [4.41, 6.34]), without significant sensitivity degradation (32/45, 71.11%, 95% confidence interval [66.39%, 75.74%], p=0.1713). We conclude that this wavelet-based postprocessor can substantially reduce the false positive rate of our CTC CAD for this important polyp size range.
Yatagai, Tsuyoshi; Shimauchi, Takatoshi; Yamaguchi, Hayato; Sakabe, Jun-Ichi; Aoshima, Masahiro; Ikeya, Shigeki; Tatsuno, Kazuki; Fujiyama, Toshiharu; Ito, Taisuke; Ojima, Toshiyuki; Tokura, Yoshiki
2018-01-01
Sensitive skin is a condition of cutaneous hypersensitivity to environmental factors. Lactic acid stinging test (LAST) is commonly used to assess sensitive skin and composed of four distinct sensations (pain, burning sensation, itch, and crawly feeling). A link between sensitive skin and barrier dysfunction has been proposed in atopic dermatitis (AD) patients. However, clinical and laboratory factors that are associated with sensitive skin remain unelucidated. To investigate relationship between sensitive skin and AD-associated markers. Forty-two Japanese AD patients and 10 healthy subjects (HS) were enrolled. AD patients were divided into extrinsic (EAD; high IgE levels) and intrinsic (IAD; normal IgE levels) types. We conducted 1% LAST by assessing the four distinct sensations and calculated the frequencies of sensitive skin in EAD, IAD, and HS. We also performed clinical AD-related tests, including transepidermal water loss (TEWL), visual analogue scale (VAS) of pruritus, and quality of life, and measured laboratory markers, including blood levels of IgE, CCL17/TARC, lactate dehydrogenase (LDH) and eosinophil counts, and concentration levels of serum Th1/Th2 cytokines. Filaggrin (FLG) mutations were examined in 21 patients. These values were subjected to correlation analyses with each of the four sensation elements. According to the standard criteria for LAST positivity, the frequencies of LAST-positive subjects were 54.8% and 10.0% in AD and HS, respectively (P=0.014). EAD patients showed a significantly (P=0.026) higher frequency of positive LAST (65.6%) than did IAD patients (20.0%). Among the four LAST sensation elements, the crawly feeling and pain scores positively correlated with VAS of pruritus, total serum IgE, mite-specific IgE, CCL17/TARC, and/or LDH. There was no association of the LAST scores with serum Th1/Th2 cytokine levels. Notably, neither TEWL nor FLG mutations correlated with LAST positivity or any sensation scores. The frequency of sensitive skin is higher in EAD than in IAD. Sensitive skin is associated with AD severity, but not necessarily with barrier condition. Copyright © 2017 Japanese Society for Investigative Dermatology. Published by Elsevier B.V. All rights reserved.
Bhatia, Risha; Morley, Colin J; Argus, Brenda; Tingay, David G; Donath, Susan; Davis, Peter G
2013-01-01
Very preterm infants can be treated with nasal continuous positive airway pressure (CPAP) from birth, but some fail. A rapid test, such as the stable microbubble test (SMT) on gastric aspirate, may identify those who can be managed successfully using CPAP. To determine if SMT can identify soon after birth, very preterm infants who may be successfully managed on CPAP alone. Stable microbubbles (diameter <15 µm) were counted in gastric aspirates taken <1 h of age from infants <30 weeks' gestation, who received CPAP from birth. Infants failed CPAP if intubated at <72 h of age. Clinicians were masked to SMT results. A receiver operating characteristic curve was generated to determine the relationship between number of microbubbles/mm(2) and subsequent intubation. 68 infants of mean (SD) 28.1 (1.4) weeks' gestation received CPAP in the delivery room at a median (interquartile range) pressure 7 (6-8) cmH2O and FiO2 0.25 (0.21-0.3). Gastric aspirates were taken at a median (interquartile range) age of 0.5 (0.3-0.6) hours. The best cut-off point for predicting CPAP success or failure was a SMT count of 8 microbubbles/mm(2). The area under the receiver operating characteristic curve was 0.8 (95% CI 0.7-0.9). A SMT count ≥8 microbubbles/mm(2) had a sensitivity of 53%, a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 60% for predicting CPAP success. Infants treated with CPAP from birth, who had SMT counts ≥8 microbubbles/mm(2) on their gastric aspirate, did not fail CPAP. Copyright © 2013 S. Karger AG, Basel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sword, Charles Keith
A scanner system and method for acquisition of position-based ultrasonic inspection data are described. The scanner system includes an inspection probe and a first non-contact linear encoder having a first sensor and a first scale to track inspection probe position. The first sensor is positioned to maintain a continuous non-contact interface between the first sensor and the first scale and to maintain a continuous alignment of the first sensor with the inspection probe. The scanner system may be used to acquire two-dimensional inspection probe position data by including a second non-contact linear encoder having a second sensor and a secondmore » scale, the second sensor positioned to maintain a continuous non-contact interface between the second sensor and the second scale and to maintain a continuous alignment of the second sensor with the first sensor.« less
The fear of cancer recurrence literature continues to move forward: a review article.
Maheu, Christine; Galica, Jacqueline
2018-03-01
The volume of literature addressing fear of cancer recurrence (FCR) is rapidly increasing. A summary of key developments in the research and treatment of FCR was published by Sharpe et al. in 2017, and the current review focuses on works published thereafter. A comprehensive literature review was conducted to provide an up-to-date summary of peer-reviewed publications focusing on FCR. The search consisted of the most recent FCR reports published between 2016 and 2017, which can be broadly categorized as: methods of assessment; associations with FCR; FCR and caregivers; and FCR interventions. FCR assessments continue to undergo revisions, which may have positive implications for clinicians and researchers seeking shorter measures to assess the FCR of their patients and study participants. However, research is needed to determine if a shorter FCR measure could be created using items that measure the construct alone, yet still retaining optimal sensitivity and specificity, or also with its determinants and consequences. Doing so would result in either unidimensional or multidimensional measure of FCR. Notwithstanding these matters in FCR assessment, the state of the literature continues to advance our understanding about characteristics of survivors with highest FCR, which is useful to identify patients in need of FCR interventions. These empirical results are useful to further investigate the theoretical distinctions of FCR.
Kubicka, Zuzanna J; Limauro, Joseph; Darnall, Robert A
2008-01-01
The goal was to estimate the level of delivered continuous positive airway pressure by measuring oral cavity pressure with the mouth closed in infants of various weights and ages treated with heated, humidified high-flow nasal cannula at flow rates of 1-5 L/minute. We hypothesized that clinically relevant levels of continuous positive airway pressure would not be achieved if a nasal leak is maintained. After performing bench measurements and demonstrating that oral cavity pressure closely approximated levels of traditionally applied nasal continuous positive airway pressure, we successfully measured oral cavity pressure during heated, humidified, high-flow nasal cannula treatment in 27 infants. Small (outer diameter: 0.2 cm) cannulae were used for all infants, and flow rates were left as ordered by providers. Bench measurements showed that, for any given leak size, there was a nearly linear relationship between flow rate and pressure. The highest pressure achieved was 4.5 cmH2O (flow rate: 8 L/minute; leak: 3 mm). In our study infants (postmenstrual age: 29.1-44.7 weeks; weight: 835-3735 g; flow rate: 1-5 L/minute), no pressure was generated with the mouth open at any flow rate. With the mouth closed, the oral cavity pressure was related to both flow rate and weight. For infants of < or = 1500 g, there was a linear relationship between flow rate and oral cavity pressure. Oral cavity pressure can estimate the level of continuous positive airway pressure. Continuous positive airway pressure generated with heated, humidified, high-flow nasal cannula treatment depends on the flow rate and weight. Only in the smallest infants with the highest flow rates, with the mouth fully closed, can clinically significant but unpredictable levels of continuous positive airway pressure be achieved. We conclude that heated, humidified high-flow nasal cannula should not be used as a replacement for delivering continuous positive airway pressure.
Schellongowski, Peter; Losert, Heidrun; Locker, Gottfried J; Laczika, Klaus; Frass, Michael; Holzinger, Ulrike; Bojic, Andja; Staudinger, Thomas
2007-04-01
To establish whether prolonged lateral steep position during continuous rotation therapy leads to improvement on pulmonary gas exchange, respiratory mechanics and hemodynamics. Prospective observational study. Intensive care unit of a university hospital. Twelve consecutive patients suffering from acute lung injury or adult respiratory distress syndrome undergoing continuous rotation therapy. Blood gas analysis, static lung compliance, blood pressure, cardiac index and pulmonary shunt fraction were measured in supine as well as in left and right lateral steep position at 62 degrees during continuous rotation therapy (phase I). Rotation was then stopped for 30 min with the patients in supine position, left and right lateral steep position, and the same measurements were performed every 10 min (phase II). Phase I and II revealed no significant changes in PaO(2)/FiO(2) ratio, mean arterial blood pressure, pulmonary shunt fraction, or cardiac index. Significantly lower static compliance was observed in lateral steep position than in supine position (p<0.001). Concomitantly, PaCO(2) was significantly lower in supine position than in left and right lateral steep position (p<0.01). Lateral steep positioning impairs the compliance of the respiratory system. Prolonged lateral steep position does not lead to benefits with respect to oxygenation or hemodynamics. Individual response to the different positions is unpredictable. The pauses in "extreme" positions should be as short as possible.
Lu, Feng; Zhang, Meihua; Culleton, Richard L; Xu, Sui; Tang, Jianxia; Zhou, Huayun; Zhu, Guoding; Gu, Yaping; Zhang, Chao; Liu, Yaobao; Wang, Weiming; Cao, Yuanyuan; Li, Julin; He, Xinlong; Cao, Jun; Gao, Qi
2017-07-26
Chloroquine (CQ) was the cornerstone of anti-malarial treatment in Africa for almost 50 years, but has been widely withdrawn due to the emergence and spread of resistance. Recent reports have suggested that CQ-susceptibility may return following the cessation of CQ usage. Here, we monitor CQ sensitivity and determine the prevalence of genetic polymorphisms in the CQ resistance transporter gene (pfcrt) of Plasmodium falciparum isolates recently imported from Africa to China. Blood samples were collected from falciparum malaria patients returning to China from various countries in Africa. Isolates were tested for their sensitivity to CQ using the SYBR Green I test ex vivo, and for a subset of samples, in vitro following culture adaptation. Mutations at positions 72-76 and codon 220 of the pfcrt gene were analyzed by sequencing and confirmed by PCR-RFLP. Correlations between drug sensitivity and pfcrt polymorphisms were investigated. Of 32 culture adapted isolates assayed, 17 (53.1%), 6 (18.8%) and 9 (28.1%) were classified as sensitive, moderately resistant, and highly resistant, respectively. In vitro CQ susceptibility was related to point mutations in the pfcrt gene, the results indicating a strong association between pfcrt genotype and drug sensitivity. A total of 292 isolates were typed at the pfcrt locus, and the prevalence of the wild type (CQ sensitive) haplotype CVMNK in isolates from East, South, North, West and Central Africa were 91.4%, 80.0%, 73.3%, 53.3% and 51.7%, respectively. The only mutant haplotype observed was CVIET, and this was almost always linked to an additional mutation at A220S. Our results suggest that a reduction in drug pressure following withdrawal of CQ as a first-line drug may lead to a resurgence in CQ sensitive parasites. The prevalence of wild-type pfcrt CQ sensitive parasites from East, South and North Africa was higher than from the West and Central areas, but this varied greatly between countries. Further surveillance is required to assess whether the prevalence of CQ resistant parasites will continue to decrease in the absence of widespread CQ usage.
El-Moamly, Amal Abdul-Rasheed; El-Sweify, Mohamed Aly; Hafez, Mohamad Abdul
2012-09-01
Lymphatic filariasis (LF) continues to be a major source of permanent disability and an impediment to socio-economic development in 73 countries where more than 1 billion people are at risk and over 120 millions are infected. The global drive to eliminate LF necessitates an increasing demand for valid, reliable and rapid diagnostic tests. This study aimed to assess the performance of the AD12 rapid format immunochromatographic test (ICT) to detect Wuchereria bancrofti circulating antigens, against the combined gold standard: TropBio Og4C3-ELISA (enzyme-linked immunosorbent assay) which detects circulating filarial antigen (CFA) and the nucleopore membrane filtration and microscopic examination. This prospective case-control study involved 647 asymptomatic migrant workers from filariasis-endemic countries. Of these specimens, 32 were positive for microfilaremia using the membrane filtration and microscopy, 142 positive by ELISA (of which 32 had microfilaremia), and 128 positive by the ICT (of which 31 had microfilaremia). The performance of the ICT was calculated against 32 true-positive and 90 true-negative cases. For the detection of CFA, the ICT had a sensitivity of 97% (95% confidence interval [CI] 91-103), specificity 100% (95% CI 100-100), Positive Predictive Value (PPV) 100% (95% CI 100-100), Negative Predictive Value (NPV) 99% (95% CI 97-101); and the total accuracy of the test was 99% (95% CI 98-101). The agreement between ICT and ELISA in detecting W. bancrofti antigens was excellent (kappa = 0.934; p = 0.000). In conclusion, the AD12-ICT test for the detection of W. bancrofti-CFA was sensitive and specific and comparable to the performance of ELISA. The ICT would be a useful additional test to facilitate the proposed strategies for control and elimination of LF. Because it is rapid, simple to perform, and does not require the use of special equipment, the ICT may be most appropriate in screening programs and in monitoring the possible risk of introducing the disease to the non-endemic countries.
Utility of Acridine Orange staining for detection of bacteria from positive blood cultures.
Neeraja, M; Lakshmi, V; Padmasri, C; Padmaja, K
2017-08-01
The diagnostic performance of AO stain was evaluated for the detection of bacteria and or fungi from positive blood cultures. The sensitivity of Gram stain (GS) was 98.26% while Acridine Orange (AO) stain proved to be more sensitive (100%) with a Positive and Negative Predictive Value of 100% each. The specificity of both the stains was 100%. Overall agreement between the two stains was 98.23% (688/700). The organisms that were missed by GS and positive by AO were Candida species (Sutton, 2006) and Gram negative bacilli (GNB) (Sutton, 2006). Sensitivity of GS was 82.35% and AO was 100% among mixed cultures. Immediate reporting of the results of AO stain would have a significant impact on clinical management of patients with serious blood stream infections. Copyright © 2017 Elsevier B.V. All rights reserved.
Perspectives on MEMS in bioengineering: a novel capacitive position microsensor.
Pedrocchi, A; Hoen, S; Ferrigno, G; Pedotti, A
2000-01-01
We describe a novel capacitive position sensor using micromachining to achieve high sensitivity and large range of motion. These sensors require a new theoretical framework to describe and optimize their performance. Employing a complete description of the electrical fields, the sensor should deviate from the standard geometries used for capacitive sensors. By this optimization, the sensor gains a twofold increase in sensitivity. Results on a PC board 10x model imply that the micromachined sensor should achieve a sensitivity of less than 10 nm over 500-micron range of travel. Some bioengineering applications are addressed, including positioning of micromirrors for laser surgery and dose control for implantable drug delivery systems.
Recent Progress in the Development of Diagnostic Tests for Malaria.
Krampa, Francis D; Aniweh, Yaw; Awandare, Gordon A; Kanyong, Prosper
2017-09-19
The impact of malaria on global health has continually prompted the need to develop effective diagnostic strategies. In malaria endemic regions, routine diagnosis is hampered by technical and infrastructural challenges to laboratories. These laboratories lack standard facilities, expertise or diagnostic supplies; thus, therapy is administered based on clinical or self-diagnosis. There is the need for accurate diagnosis of malaria due to the continuous increase in the cost of medication, and the emergence and spread of drug resistant strains. However, the widely utilized Giemsa-stained microscopy and immunochromatographic tests for malaria are liable to several drawbacks, including inadequate sensitivity and false-positive outcomes. Alternative methods that offer improvements in performance are either expensive, have longer turnaround time or require a level of expertise that makes them unsuitable for point-of-care (POC) applications. These gaps necessitate exploration of more efficient detection techniques with the potential of POC applications, especially in resource-limited settings. This minireview discusses some of the recent trends and new approaches that are seeking to improve the clinical diagnosis of malaria.
Chaos and unpredictability in evolution of cooperation in continuous time
NASA Astrophysics Data System (ADS)
You, Taekho; Kwon, Minji; Jo, Hang-Hyun; Jung, Woo-Sung; Baek, Seung Ki
2017-12-01
Cooperators benefit others with paying costs. Evolution of cooperation crucially depends on the cost-benefit ratio of cooperation, denoted as c . In this work, we investigate the infinitely repeated prisoner's dilemma for various values of c with four of the representative memory-one strategies, i.e., unconditional cooperation, unconditional defection, tit-for-tat, and win-stay-lose-shift. We consider replicator dynamics which deterministically describes how the fraction of each strategy evolves over time in an infinite-sized well-mixed population in the presence of implementation error and mutation among the four strategies. Our finding is that this three-dimensional continuous-time dynamics exhibits chaos through a bifurcation sequence similar to that of a logistic map as c varies. If mutation occurs with rate μ ≪1 , the position of the bifurcation sequence on the c axis is numerically found to scale as μ0.1, and such sensitivity to μ suggests that mutation may have nonperturbative effects on evolutionary paths. It demonstrates how the microscopic randomness of the mutation process can be amplified to macroscopic unpredictability by evolutionary dynamics.
Sex differences in the time course of emotion.
Gard, Marja Germans; Kring, Ann M
2007-05-01
Conventional wisdom holds that women are more "emotional" than men. However, research evidence suggests that sex differences in emotion are considerably more complex. The authors tested hypotheses about sex differences in the engagement of the approach and avoidance motivational systems thought to underpin emotional responses. The authors measured reported emotional experience and startle response magnitude both during the presentation and after the offset of emotional stimuli that engage these motivational systems to assess whether men and women differ in their patterns of immediate response to emotional stimuli and in their patterns of recovery from these responses. Our findings indicated that women were more experientially reactive to negative, but not positive, emotional pictures compared to men, and that women scored higher than men on measure of aversive motivational system sensitivity. Although both men and women exhibited potentiation of the startle response during the presentation of negative pictures relative to neutral pictures, only women continued to show this relative potentiation during the recovery period, indicating that women were continuing to engage the aversive motivational system after the offset of negative emotional pictures.
Continuous time of flight measurements in a Lissajous configuration.
Dobos, G; Hárs, G
2017-01-01
Short pulses used by traditional time-of-flight mass spectrometers limit their duty cycle, pose space-charge issues, and require high speed detectors and electronics. The motivation behind the invention of continuous time of flight mass spectrometers was to mitigate these problems, by increasing the number of ions reaching the detector and eliminating the need for fast data acquisition systems. The most crucial components of these spectrometers are their modulators: they determine both the maximal modulation frequency and the modulation depth. Through these parameters they limit the achievable mass resolution and signal-to-noise ratio. In this paper, a new kind of setup is presented which modulates the beam by deflecting it in two perpendicular directions and collects ions on a position sensitive detector. Such an Lissajous time of flight spectrometer achieves modulation without the use of slits or apertures, making it possible for all ions to reach the detector, thereby increasing the transmission and signal-to-noise ratio. In this paper, we provide the mathematical description of the system, discuss its properties, and present a practical demonstration of the principle.
Rapid detection of urinary polyomavirus BK by heterodyne-based surface plasmon resonance biosensor
NASA Astrophysics Data System (ADS)
Su, Li-Chen; Tian, Ya-Chung; Chang, Ying-Feng; Chou, Chien; Lai, Chao-Sung
2014-01-01
In renal transplant patients, immunosuppressive therapy may result in the reactivation of polyomavirus BK (BKV), leading to polyomavirus-associated nephropathy (PVAN), which inevitably causes allograft failure. Since the treatment outcomes of PVAN remain unsatisfactory, early identification and continuous monitoring of BKV reactivation and reduction of immunosuppressants are essential to prevent PVAN development. The present study demonstrated that the developed dual-channel heterodyne-based surface plasmon resonance (SPR) biosensor is applicable for the rapid detection of urinary BKV. The use of a symmetrical reference channel integrated with the poly(ethylene glycol)-based low-fouling self-assembled monolayer to reduce the environmental variations and the nonspecific noise was proven to enhance the sensitivity in urinary BKV detection. Experimentally, the detection limit of the biosensor for BKV detection was estimated to be around 8500 copies/mL. In addition, urine samples from five renal transplant patients were tested to rapidly distinguish PVAN-positive and PVAN-negative renal transplant patients. By virtue of its simplicity, rapidity, and applicability, the SPR biosensor is a remarkable potential to be used for continuous clinical monitoring of BKV reactivation.
NASA Astrophysics Data System (ADS)
Dai, Yanqiu; Xu, Huimei; Wang, Haoyu; Lu, Yonghua; Wang, Pei
2018-06-01
We experimentally demonstrated a high sensitivity of surface plasmon resonance (SPR) sensor with silver rectangular grating coupling. The reflection spectra of the silver gratings indicated that surface plasmon resonance can be excited by either positive or negative order diffraction of the grating, depending on the period of the gratings. Comparing to prism-coupled SPR sensor, the sensitivities are higher for negative order diffraction coupling in bigger coupling angle, but much smaller for positive order diffraction coupling of the gratings. High sensitivity of 254.13 degree/RIU is experimentally realized by grating-based SPR sensor in the negative diffraction excitation mode. Our work paves the way for compact and sensitive SPR sensor in the applications of biochemical and gas sensing.
Evidence for isoleucine as a positive effector of the ilvBN operon in Salmonella typhimurium.
Davidson, J P; Wilson, D J
1991-08-15
Concerted efforts were directed towards understanding the control of acetohydroxy acid synthase (AHAS) in the gyrB mutant hisU1820 of Salmonella typhimurium. A media shift from valine to valine plus isoleucine causes a dramatic 4 to 5 fold burst of AHAS valine sensitive activity which appears to be dependent on translation. DJ19, an isolated valine sensitive derivative of the gyrB mutant, maintains a dramatic increase in AHAS valine sensitive activity upon the addition of isoleucine to valine supplemented cultures, suggesting that the isoleucine effect is specific for valine sensitive AHAS. Evidence supports isoleucine as a positive effector on valine sensitive AHAS expression and that the gyrB mutation accentuates the isoleucine effect.
Farreny, Aida; Del Rey-Mejías, Ángel; Escartin, Gemma; Usall, Judith; Tous, Núria; Haro, Josep Maria; Ochoa, Susana
2016-07-01
Schizophrenia involves marked motivational and learning deficits that may reflect abnormalities in reward processing. The purpose of this study was to examine positive and negative feedback sensitivity in schizophrenia using computational modeling derived from the Wisconsin Card Sorting Test (WCST). We also aimed to explore feedback sensitivity in a sample with bipolar disorder. Eighty-three individuals with schizophrenia and 27 with bipolar disorder were included. Demographic, clinical and cognitive outcomes, together with the WCST, were considered in both samples. Computational modeling was performed using the R syntax to calculate 3 parameters based on trial-by-trial execution on the WCST: reward sensitivity (R), punishment sensitivity (P), and choice consistency (D). The associations between outcome variables and the parameters were investigated. Positive and negative sensitivity showed deficits, but P parameter was clearly diminished in schizophrenia. Cognitive variables, age, and symptoms were associated with R, P, and D parameters in schizophrenia. The sample with bipolar disorder would show cognitive deficits and feedback abnormalities to a lesser extent than individuals with schizophrenia. Negative feedback sensitivity demonstrated greater deficit in both samples. Idiosyncratic cognitive requirements in the WCST might introduce confusion when supposing model-free reinforcement learning. Negative symptoms of schizophrenia were related to lower feedback sensitivity and less goal-directed patterns of choice. Copyright © 2016 Elsevier Inc. All rights reserved.
Du, Pan; Kibbe, Warren A; Lin, Simon M
2006-09-01
A major problem for current peak detection algorithms is that noise in mass spectrometry (MS) spectra gives rise to a high rate of false positives. The false positive rate is especially problematic in detecting peaks with low amplitudes. Usually, various baseline correction algorithms and smoothing methods are applied before attempting peak detection. This approach is very sensitive to the amount of smoothing and aggressiveness of the baseline correction, which contribute to making peak detection results inconsistent between runs, instrumentation and analysis methods. Most peak detection algorithms simply identify peaks based on amplitude, ignoring the additional information present in the shape of the peaks in a spectrum. In our experience, 'true' peaks have characteristic shapes, and providing a shape-matching function that provides a 'goodness of fit' coefficient should provide a more robust peak identification method. Based on these observations, a continuous wavelet transform (CWT)-based peak detection algorithm has been devised that identifies peaks with different scales and amplitudes. By transforming the spectrum into wavelet space, the pattern-matching problem is simplified and in addition provides a powerful technique for identifying and separating the signal from the spike noise and colored noise. This transformation, with the additional information provided by the 2D CWT coefficients can greatly enhance the effective signal-to-noise ratio. Furthermore, with this technique no baseline removal or peak smoothing preprocessing steps are required before peak detection, and this improves the robustness of peak detection under a variety of conditions. The algorithm was evaluated with SELDI-TOF spectra with known polypeptide positions. Comparisons with two other popular algorithms were performed. The results show the CWT-based algorithm can identify both strong and weak peaks while keeping false positive rate low. The algorithm is implemented in R and will be included as an open source module in the Bioconductor project.
Huang, Terry T-K; Nansel, Tonja R; Belsheim, Allen R; Morrison, John A
2008-02-01
To estimate the sensitivity, specificity, and predictive values of pediatric metabolic syndrome (MetS) components (obesity, fasting glucose, triglycerides, high-density lipoprotein, and blood pressure) at various cutoff points in relation to adult MetS. Data from the National Heart, Lung, and Blood Institute Lipid Research Clinics Princeton Prevalence Study (1973-1976) and the Princeton Follow-up Study (2000-2004) were used to calculate sensitivity, specificity, and positive and negative predictive values for each component at a given cutoff point and for aggregates of components. Individual pediatric components alone showed low to moderate sensitivity, high specificity, and moderate predictive values in relation to adult MetS. When all 5 pediatric MetS components were considered, the presence of at least 1 abnormality had higher sensitivity for adult MetS than individual components alone. When multiple abnormalities were mandatory for MetS, positive predictive value was high and sensitivity was low. Childhood body mass alone showed neither high sensitivity nor high positive predictive value for adult MetS. Considering multiple metabolic variables in childhood can improve the predictive usefulness for adult MetS, compared with each component or body mass alone. MetS variables may be useful for identifying some children who are at risk for prevention interventions.
Giacometti, Paolo; Diamond, Solomon G.
2014-01-01
Abstract. This study investigates the correspondence of the cortical sensitivity of electroencephalography (EEG) and near-infrared spectroscopy (NIRS). EEG forward model sensitivity to the cerebral cortex was calculated for 329 EEG electrodes following the 10-5 EEG positioning system using a segmented structural magnetic resonance imaging scan of a human subject. NIRS forward model sensitivity was calculated for the same subject using 156 NIRS source-detector pairs selected from 32 source and 32 detector optodes positioned on the scalp using a subset of the 10-5 EEG positioning system. Sensitivity correlations between colocalized NIRS source-detector pair groups and EEG channels yielded R=0.46±0.08. Groups of NIRS source-detector pairs with maximum correlations to EEG electrode sensitivities are tabulated. The mean correlation between the point spread functions for EEG and NIRS regions of interest (ROI) was R=0.43±0.07. Spherical ROIs with radii of 26 mm yielded the maximum correlation between EEG and NIRS averaged across all cortical mesh nodes. These sensitivity correlations between EEG and NIRS should be taken into account when designing multimodal studies of neurovascular coupling and when using NIRS as a statistical prior for EEG source localization. PMID:25558462
Corbett-Detig, Russell B.
2016-01-01
Chromosomal inversions are widespread among taxa, and have been implicated in a number of biological processes including adaptation, sex chromosome evolution, and segregation distortion. Consistent with selection favoring linkage between loci, it is well established that length is a selected trait of inversions. However, the factors that affect the distribution of inversion breakpoints remain poorly understood. “Sensitive sites” have been mapped on all euchromatic chromosome arms in Drosophila melanogaster, and may be a source of natural selection on inversion breakpoint positions. Briefly, sensitive sites are genomic regions wherein proximal structural rearrangements result in large reductions in local recombination rates in heterozygotes. Here, I show that breakpoints of common inversions are significantly more likely to lie within a cytological band containing a sensitive site than are breakpoints of rare inversions. Furthermore, common inversions for which neither breakpoint intersects a sensitive site are significantly longer than rare inversions, but common inversions whose breakpoints intersect a sensitive site show no evidence for increased length. I interpret these results to mean that selection favors inversions whose breakpoints disrupt synteny near to sensitive sites, possibly because these inversions suppress recombination in large genomic regions. To my knowledge this is the first evidence consistent with positive selection acting on inversion breakpoint positions. PMID:27343234
Corbett-Detig, Russell B
2016-09-01
Chromosomal inversions are widespread among taxa, and have been implicated in a number of biological processes including adaptation, sex chromosome evolution, and segregation distortion. Consistent with selection favoring linkage between loci, it is well established that length is a selected trait of inversions. However, the factors that affect the distribution of inversion breakpoints remain poorly understood. "Sensitive sites" have been mapped on all euchromatic chromosome arms in Drosophila melanogaster, and may be a source of natural selection on inversion breakpoint positions. Briefly, sensitive sites are genomic regions wherein proximal structural rearrangements result in large reductions in local recombination rates in heterozygotes. Here, I show that breakpoints of common inversions are significantly more likely to lie within a cytological band containing a sensitive site than are breakpoints of rare inversions. Furthermore, common inversions for which neither breakpoint intersects a sensitive site are significantly longer than rare inversions, but common inversions whose breakpoints intersect a sensitive site show no evidence for increased length. I interpret these results to mean that selection favors inversions whose breakpoints disrupt synteny near to sensitive sites, possibly because these inversions suppress recombination in large genomic regions. To my knowledge this is the first evidence consistent with positive selection acting on inversion breakpoint positions. Copyright © 2016 by the Genetics Society of America.
Juffer, Femmie; Struis, Estelle; Werner, Claudia; Bakermans-Kranenburg, Marian J
2017-01-01
Secure attachment relationships are essential for children's current and later development. From attachment theory and research, it can be derived that sensitive parenting is the key to positive parent-child relationships. Is it possible to design effective interventions to enhance sensitive parenting? In this article, we review elements that are crucial for effective attachment-based interventions, and we proceed with illustrations from the Video-feedback Intervention to promote Positive Parenting and Sensitive Discipline (VIPP-SD). We describe how this intervention program was developed, how it has been implemented in practice in different types of families and in daycare settings, and how effective the program is. We conclude that intervention programs like the VIPP-SD could play an important role in the community by serving families in need of parenting support.
Juffer, Femmie; Bakermans-Kranenburg, Marian J; van IJzendoorn, Marinus H
2017-06-01
Video-feedback Intervention to promote Positive Parenting and Sensitive Discipline (VIPP-SD) is a social-learning and attachment-based intervention using video feedback to support sensitive parenting and at the same time setting firm limits. Empirical studies and meta-analyses have shown that sensitive parenting is the key determinant to promote secure child-parent attachment relationships and that adequate parental discipline contributes to fewer behavior problems in children. Building on this evidence, VIPP-SD has been tested in various populations of at-risk parents and vulnerable children (in the age range of zero to six years), as well as in the context of child care. In twelve randomized controlled trials including 1116 parents and caregivers, VIPP-SD proved to be effective in promoting sensitive caregiving, while positive social-emotional child outcomes were also found. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Kosulya, A. V.; Verbitskii, V. G.
2017-09-01
The dependence of the transverse section of an electron beam on the distance between plates and on the accelerating potential difference is determined for a chevron unit of a microelectronic position-sensitive detector (MPSD) with two microchannel plates. The geometry of the MPSD chevron unit is designed and optimized.
Event Perception and Pattern Perception in Early Infancy.
ERIC Educational Resources Information Center
Vurpillot, Eliane
Human infants are sensitive from birth to some intrinsic properties of objects; they are also sensitive to position. During the first weeks of life, pertinent dimensions of differentiation between objects are relative to global properties of the entire object or pattern. Position is defined by the direction of a displacement: the trajectory…
Sensitivity to Social Contingency and Positive Emotion in 2-Month-Olds
ERIC Educational Resources Information Center
Soussignan, Robert; Nadel, Jacqueline; Canet, Pierre; Gerardin, Priscille
2006-01-01
This study was aimed at sorting out conflicting results in the literature concerning 2-month-olds' sensitivity to interpersonal contingency, and investigated the potential role of infants' positive emotion in contingency detection. Infants were randomly assigned to an experimental group (EG) that was presented an uninterrupted live-replay-live…
Gawke, Jason C; Gorgievski, Marjan J; Bakker, Arnold B
2017-12-28
Ample studies have confirmed the benefits of intrapreneurship (i.e., employee behaviors that contribute to new venture creation and strategic renewal activities) for firm performance, but research on the personal costs and benefits of engaging in intrapreneurial activities for employees is lacking. Building on job demands-resources and reinforcement sensitivity theories, we examined how employees' reinforcement sensitivity qualified the relationship among their intrapreneurial behavior, subjective well-being, and other-rated job performance. Using a sample of 241 employee dyads, the results of moderated mediation analyses confirmed that employee intrapreneurship related positively to work engagement for employees high (vs. low) in sensitivity to rewards (behavioral approach system), which subsequently related positively to innovativeness and in-role performance and negatively to work avoidance. In contrast, employee intrapreneurship related positively to exhaustion for employees high (vs. low) in sensitivity to punishments (behavioral inhibition system), which subsequently related positively to work avoidance and negatively to in-role performance (but not to innovativeness). Theoretical and practical implications are discussed. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Bayer, Thomas; Fries, Simon; Schweizer, Andreas; Schöffl, Isabelle; Janka, Rolf; Bongartz, Georg
2015-01-01
The objectives of this study were the evaluation of flexor tendon pulley rupture of the fingers in the crimp grip position using magnetic resonance imaging (MRI) and the comparison of the results with MRI in the neutral position in a cadaver study. MRI in the crimp grip position and in the neutral position was performed in 21 cadaver fingers with artificially created flexor tendon pulley tears (combined pulley rupture, n = 14; single pulley rupture, n = 7). Measurement of the distance between the tendon and bone was performed. Images were evaluated by two readers, first independently and in cases of discrepancy in consensus. Sensitivity and specificity for detecting combined pulley ruptures were calculated. Tendon bone distances were significantly higher in the crimp grip position than in the neutral position. Sensitivity and specificity for detecting combined pulley rupture were 92.86 % and 100 % respectively in the crimp grip position and 78.57 % and 85.71 % respectively in the neutral position. Kappa values for interobserver reliability were 0.87 in the crimp grip position and 0.59 in the neutral position. MRI examination in the crimp grip position results in higher tendon bone distances by subjecting the pulleys to a higher strain, which facilitates image evaluation with higher interobserver reliability, higher sensitivity, and higher specificity for combined pulley rupture compared with examination in the neutral position.
Bache, Cathleen; Springer, Anne; Noack, Hannes; Stadler, Waltraud; Kopp, Franziska; Lindenberger, Ulman; Werkle-Bergner, Markus
2017-01-01
Research has shown that infants are able to track a moving target efficiently - even if it is transiently occluded from sight. This basic ability allows prediction of when and where events happen in everyday life. Yet, it is unclear whether, and how, infants internally represent the time course of ongoing movements to derive predictions. In this study, 10-month-old crawlers observed the video of a same-aged crawling baby that was transiently occluded and reappeared in either a temporally continuous or non-continuous manner (i.e., delayed by 500 ms vs. forwarded by 500 ms relative to the real-time movement). Eye movement and rhythmic neural brain activity (EEG) were measured simultaneously. Eye movement analyses showed that infants were sensitive to slight temporal shifts in movement continuation after occlusion. Furthermore, brain activity associated with sensorimotor processing differed between observation of continuous and non-continuous movements. Early sensitivity to an action's timing may hence be explained within the internal real-time simulation account of action observation. Overall, the results support the hypothesis that 10-month-old infants are well prepared for internal representation of the time course of observed movements that are within the infants' current motor repertoire.
Bache, Cathleen; Springer, Anne; Noack, Hannes; Stadler, Waltraud; Kopp, Franziska; Lindenberger, Ulman; Werkle-Bergner, Markus
2017-01-01
Research has shown that infants are able to track a moving target efficiently – even if it is transiently occluded from sight. This basic ability allows prediction of when and where events happen in everyday life. Yet, it is unclear whether, and how, infants internally represent the time course of ongoing movements to derive predictions. In this study, 10-month-old crawlers observed the video of a same-aged crawling baby that was transiently occluded and reappeared in either a temporally continuous or non-continuous manner (i.e., delayed by 500 ms vs. forwarded by 500 ms relative to the real-time movement). Eye movement and rhythmic neural brain activity (EEG) were measured simultaneously. Eye movement analyses showed that infants were sensitive to slight temporal shifts in movement continuation after occlusion. Furthermore, brain activity associated with sensorimotor processing differed between observation of continuous and non-continuous movements. Early sensitivity to an action’s timing may hence be explained within the internal real-time simulation account of action observation. Overall, the results support the hypothesis that 10-month-old infants are well prepared for internal representation of the time course of observed movements that are within the infants’ current motor repertoire. PMID:28769831
DOT National Transportation Integrated Search
2012-01-01
Purpose: : To determine ranking of important parameters and the overall sensitivity to values of variables in MOVES : To allow a greater understanding of the MOVES modeling process for users : Continued support by FHWA to transportation modeling comm...
Cosmetic Contact Sensitivity in Patients with Melasma: Results of a Pilot Study
Prabha, Neel; Mahajan, Vikram K.; Mehta, Karaninder S.; Chauhan, Pushpinder S.
2014-01-01
Background. Some of the patients with melasma perhaps have pigmented cosmetic dermatitis. However, cosmetic contact sensitivity in melasma remains poorly studied particularly in the Indian context. Objectives. To study cosmetic contact sensitivity in patients with melasma. Materials and Methods. 67 (F : M = 55 : 12) consecutive patients with melasma between 19 and 49 years of age were patch tested sequentially during January–December, 2012, with Indian Cosmetic and Fragrance Series, Indian Sunscreen Series, p-phenylenediamine, and patient's own cosmetic products. Results. 52 (78%) patients were in the age group of 20–40 years. The duration of melasma varied from 1 month to 20 years. Centrofacial, malar, and mandibular patterns were observed in 48 (72%), 18 (27%), and 1 (1%) patients, respectively. Indian Cosmetics and Fragrance Series elicited positive reactions in 29 (43.3%) patients. Cetrimide was the most common contact sensitizers eliciting positivity in 15 (52%) patients, followed by gallate mix in 9 (31%) patients and thiomersal in 7 (24%) patients. Only 2 of the 42 patients showed positive reaction from their own cosmetics while the other 5 patients had irritant reaction. Indian Sunscreen Series did not elicit any positive reaction. Conclusion. Cosmetics contact sensitivity appears as an important cause of melasma not associated with pregnancy, lactation, or hormone therapy. PMID:25132846
Laloux, C; Gouel, F; Lachaud, C; Timmerman, K; Do Van, B; Jonneaux, A; Petrault, M; Garcon, G; Rouaix, N; Moreau, C; Bordet, R; Duce, J A; Devedjian, J C; Devos, D
2017-07-01
In Parkinson's disease (PD) depletion of dopamine in the nigro-striatal pathway is a main pathological hallmark that requires continuous and focal restoration. Current predominant treatment with intermittent oral administration of its precursor, Levodopa (l-dopa), remains the gold standard but pharmacological drawbacks trigger motor fluctuations and dyskinesia. Continuous intracerebroventricular (i.c.v.) administration of dopamine previously failed as a therapy because of an inability to resolve the accelerated dopamine oxidation and tachyphylaxia. We aim to overcome prior challenges by demonstrating treatment feasibility and efficacy of continuous i.c.v. of dopamine close to the striatum. Dopamine prepared either anaerobically (A-dopamine) or aerobically (O-dopamine) in the presence or absence of a conservator (sodium metabisulfite, SMBS) was assessed upon acute MPTP and chronic 6-OHDA lesioning and compared to peripheral l-dopa treatment. A-dopamine restored motor function and induced a dose dependent increase of nigro-striatal tyrosine hydroxylase positive neurons in mice after 7days of MPTP insult that was not evident with either O-dopamine or l-dopa. In the 6-OHDA rat model, continuous circadian i.c.v. injection of A-dopamine over 30days also improved motor activity without occurrence of tachyphylaxia. This safety profile was highly favorable as A-dopamine did not induce dyskinesia or behavioral sensitization as observed with peripheral l-dopa treatment. Indicative of a new therapeutic strategy for patients suffering from l-dopa related complications with dyskinesia, continuous i.c.v. of A-dopamine has greater efficacy in mediating motor impairment over a large therapeutic index without inducing dyskinesia and tachyphylaxia. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Anger, Hal O.; Martin, Donn C.; Lampton, Michael L.
1983-01-01
A radiation imaging system using a charge multiplier and a position sensitive anode in the form of periodically arranged sets of interconnected anode regions for detecting the position of the centroid of a charge cloud arriving thereat from the charge multiplier. Various forms of improved position sensitive anodes having single plane electrode connections are disclosed. Various analog and digital signal processing systems are disclosed, including systems which use the fast response of microchannel plates, anodes and preamps to perform scintillation pulse height analysis digitally.
Functional analysis of inappropriate social interactions in students with Asperger's syndrome.
Roantree, Christina F; Kennedy, Craig H
2012-01-01
We analyzed the inappropriate social interactions of 3 students with Asperger's syndrome whose behavior was maintained by social positive reinforcement. We tested whether inappropriate social behavior was sensitive to social positive reinforcement contingencies and whether such contingencies could be reversed to increase the probability of socially appropriate responding. Our results show that social positive reinforcers can be identified for inappropriate social interactions and that appropriate social behaviors can be sensitive to reinforcement contingency reversals.
Can hip abduction and external rotation discriminate sacroiliac joint pain?
Adhia, Divya Bharatkumar; Tumilty, Steve; Mani, Ramakrishnan; Milosavljevic, Stephan; Bussey, Melanie D
2016-02-01
The primary aim of the study is to determine if Hip Abduction and External Rotation (HABER) test is capable of reproducing familiar pain in individuals with low back pain (LBP) of sacroiliac joint (SIJ) origin (SIJ-positive) when compared with LBP of Non-SIJ origin (SIJ-negative). If so, the secondary aim is to determine the diagnostic accuracy of HABER test against the reference standard of pain provocation tests, and to determine which increments of the HABER test has highest sensitivity and specificity for identifying SIJ-positive individuals. Single-blinded diagnostic accuracy study. Participants [n(122)] between ages of 18-50 y, suffering from chronic non-specific LBP (≥3 months) volunteered in the study. An experienced musculoskeletal physiotherapist evaluated and classified participants into either SIJ-positive [n(45)] or SIJ-negative [n(77)], based on reference standard of pain provocation tests [≥3 positive tests = SIJ-positive]. Another musculoskeletal physiotherapist, blinded to clinical groups, evaluated participants for reproduction of familiar pain during each increment (10°, 20°, 30°, 40°, and 50°) of HABER test. The HABER test reproduced familiar pain in SIJ-positive individuals when compared with SIJ-negative individuals [p (0.001), R(2) (0.38), Exp(β) (5.95-10.32)], and demonstrated moderate level of sensitivity (67%-78%) and specificity (71%-72%) for identifying SIJ-positive individuals. Receiver operator curve analysis demonstrated that the HABER increments of ≥30° have the highest sensitivity (83%-100%) and specificity (52%-64%). The HABER test is capable of reproducing familiar pain in SIJ-positive LBP individuals and has moderate levels of sensitivity and specificity for identifying SIJ-positive LBP individuals. Copyright © 2015 Elsevier Ltd. All rights reserved.
Performance of a Novel Algorithm Using Automated Digital Microscopy for Diagnosing Tuberculosis.
Ismail, Nazir A; Omar, Shaheed V; Lewis, James J; Dowdy, David W; Dreyer, Andries W; van der Meulen, Hermina; Nconjana, George; Clark, David A; Churchyard, Gavin J
2015-06-15
TBDx automated microscopy is a novel technology that processes digital microscopic images to identify acid-fast bacilli (AFB). Use of TBDx as part of a diagnostic algorithm could improve the diagnosis of tuberculosis (TB), but its performance characteristics have not yet been formally tested. To evaluate the performance of the TBDx automated microscopy system in algorithms for diagnosis of TB. Prospective samples from patients with presumed TB were processed in parallel with conventional smear microscopy, TBDx microscopy, and liquid culture. All TBDx-positive specimens were also tested with the Xpert MTB/RIF (GXP) assay. We evaluated the sensitivity and specificity of two algorithms-(1) TBDx-GXP (TBDx with positive specimens tested by Xpert MTB/RIF) and (2) TBDx alone-against the gold standard liquid media culture. Of 1,210 samples, 1,009 were eligible for evaluation, of which 109 were culture positive for Mycobacterium tuberculosis. The TBDx system identified 70 specimens (68 culture positive) as having 10 or more putative AFB (high positive) and 207 (19 culture positive) as having 1-9 putative AFB (low positive). An algorithm in which "low-positive" results on TBDx were confirmed by GXP had 78% sensitivity (85 of 109) and 99.8% specificity (889 of 900), requiring 21% (207 of 1,009) specimens to be processed by GXP. As a stand-alone test, a "high-positive" result on TBDx had 62% sensitivity and 99.7% specificity. TBDx used in diagnostic algorithms with GXP provided reasonable sensitivity and high specificity for active TB while dramatically reducing the number GXP tests performed. As a stand-alone microscopy system, its performance was equivalent to that of a highly experienced TB microscopist.
Wu, Peili; Zhou, Chu; Zhou, Yang; Ren, Xianlong; Chen, Xi; Zhao, Junshi; Deng, Xiaojun; Rou, Keming; Wu, Zunyou
2015-04-01
Face-to-face interview (FTFI) and polling booth survey (PBS) were applied to compare the high risk behavior among HIV-positive clients of female sex workers (CFSWs). This study was conducted in antiretroviral therapy (ART) out-patients centers in Hengyang city, where clients who had been informed on their HIV-positive status for 6 months or longer were recruited. FTFI was first used to tackle on 8 sensitive questions related to sexual behavior, followed by PBS to poke on the same questions. Results from FTFI and PBS were then compared. Compared with FIFI, results in the PBS showed higher proportion of participants who reported "having had history of sexually transmitted diseases before knowing that they were infected with HIV" (40.6% vs. 24.2%) but lower proportions on "frequency of having sex with regular sexual partner less than 4 times per month" and "using condoms consistently with regular sexual partners in past 6 months (44.4% vs. 63.0%)". There were no significant differences in the remaining 5 questions shown in the results from the two methods. HIV-positive CFSWs continued to practice unsafe sexual behaviors after knowing their HIV related status. Compared with FTFI, PBS seemed to have revealed higher proportion of unsafe sex behaviors, so as to generated more reliable data. While comparing with PBS, the traditional FTFI might have underestimated the risk behaviors among those HIV-positive CFSWs.
Cui, Yong; Robinson, Jason D; Engelmann, Jeffrey M; Lam, Cho Y; Minnix, Jennifer A; Karam-Hage, Maher; Wetter, David W; Dani, John A; Kosten, Thomas R; Cinciripini, Paul M
2015-06-01
Nicotine dependence has been suggested to be related to reinforcement sensitivity, which encompasses behavioral predispositions either to avoid aversive (behavioral inhibition) or to approach appetitive (behavioral activation) stimuli. Reinforcement sensitivity may shape motives for nicotine use and offer potential targets for personalized smoking cessation therapy. However, little is known regarding how reinforcement sensitivity is related to motivational processes implicated in the maintenance of smoking. Additionally, women and men differ in reinforcement sensitivity, and such difference may cause distinct relationships between reinforcement sensitivity and motivational processes for female and male smokers. In this study, the authors characterized reinforcement sensitivity in relation to affect, smoking-related reinforcement motives, and affective responses, using self-report and psychophysiological measures, in over 200 smokers before treating them. The Behavioral Inhibition/Activation Scales (BIS/BAS; Carver & White, 1994) was used to measure reinforcement sensitivity. In female and male smokers, BIS was similarly associated with negative affect and negative reinforcement of smoking. However, positive affect was positively associated with BAS Drive scores in male smokers, and this association was reversed in female smokers. BIS was positively associated with corrugator electromyographic reactivity toward negative stimuli and left frontal electroencephalogram alpha asymmetry. Female and male smokers showed similar relationships for these physiological measures. These findings suggest that reinforcement sensitivity underpins important motivational processes (e.g., affect), and gender is a moderating factor for these relationships. Future personalized smoking intervention, particularly among more dependent treatment-seeking smokers, may experiment to target individual differences in reinforcement sensitivity. (PsycINFO Database Record (c) 2015 APA, all rights reserved).
Phillips, Benjamin U; Dewan, Sigma; Nilsson, Simon R O; Robbins, Trevor W; Heath, Christopher J; Saksida, Lisa M; Bussey, Timothy J; Alsiö, Johan
2018-04-22
Dysregulation of the serotonin (5-HT) system is a pathophysiological component in major depressive disorder (MDD), a condition closely associated with abnormal emotional responsivity to positive and negative feedback. However, the precise mechanism through which 5-HT tone biases feedback responsivity remains unclear. 5-HT2C receptors (5-HT2CRs) are closely linked with aspects of depressive symptomatology, including abnormalities in reinforcement processes and response to stress. Thus, we aimed to determine the impact of 5-HT2CR function on response to feedback in biased reinforcement learning. We used two touchscreen assays designed to assess the impact of positive and negative feedback on probabilistic reinforcement in mice, including a novel valence-probe visual discrimination (VPVD) and a probabilistic reversal learning procedure (PRL). Systemic administration of a 5-HT2CR agonist and antagonist resulted in selective changes in the balance of feedback sensitivity bias on these tasks. Specifically, on VPVD, SB 242084, the 5-HT2CR antagonist, impaired acquisition of a discrimination dependent on appropriate integration of positive and negative feedback. On PRL, SB 242084 at 1 mg/kg resulted in changes in behaviour consistent with reduced sensitivity to positive feedback. In contrast, WAY 163909, the 5-HT2CR agonist, resulted in changes associated with increased sensitivity to positive feedback and decreased sensitivity to negative feedback. These results suggest that 5-HT2CRs tightly regulate feedback sensitivity bias in mice with consequent effects on learning and cognitive flexibility and specify a framework for the influence of 5-HT2CRs on sensitivity to reinforcement.
Sensitivity of Gram stain in the diagnosis of urethritis in men.
Orellana, M Angeles; Gómez-Lus, M Luisa; Lora, David
2012-06-01
Acute urethritis is among the most common types of sexually transmitted diseases in men. The diagnosis usually requires microscopic evidence of urethritis, but sometimes urethral pathogens are detected in asymptomatic men without such evidence. The aims of this study were to assess the sensitivity of Gram stain in men with urethral symptoms and to relate it to the microorganisms isolated. Between January 2006 and December 2007, 491 urethral samples were analysed. The authors assessed the presence of leukocytes by Gram stain and tested specifically for Chlamydia trachomatis, Ureaplasma urealyticum, Mycoplasma hominis and Trichomonas vaginalis, as well as analysing the results of conventional culture. The percentages of positive samples as a function of Gram category were two or less polymorphonuclear leukocytes (PMNLs)/high-power field (HPF) 25% (92/364), three to four PMNLs/HPF 32% (18/57) and five or more PMNLs/HPF 54% (38/70). Classing samples with more than two PMNLs/HPF as positive, the sensitivity, specificity and positive likelihood ratio for Gram stain were 38% (95% CI 30 to 46), 79% (95% CI 75 to 84) and 1.8 (95% CI 1.4 to 2.4), respectively. On the other hand, taking as positive five or more PMNLs/HPF, the sensitivity, specificity and positive likelihood ratio for Gram stain were 26% (95% CI 18 to 33), 91% (95% CI 87 to 94) and 2.7 (95% CI 1.8 to 4.2), respectively. The sensitivity of Gram stain to Neisseria gonorrhoeae, Chlamydia trachomatis and Ureaplasma urealyticum were 80% (95% CI 64 to 96), 23% (95% CI 8 to 39) and 11% (95% CI 2 to 20), respectively. The low sensitivity of Gram stain means that negative results do not exclude the presence of urethritis in symptomatic patients.
5 CFR 831.903 - Conditions for coverage in primary positions.
Code of Federal Regulations, 2010 CFR
2010-01-01
... positions. 831.903 Section 831.903 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE REGULATIONS (CONTINUED) RETIREMENT Law Enforcement Officers and Firefighters § 831.903 Conditions... the employing agency head to be a primary law enforcement officer or firefighter position is covered...
5 CFR 831.904 - Conditions for coverage in secondary positions.
Code of Federal Regulations, 2010 CFR
2010-01-01
... positions. 831.904 Section 831.904 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE REGULATIONS (CONTINUED) RETIREMENT Law Enforcement Officers and Firefighters § 831.904 Conditions... by the employing agency head to be a secondary law enforcement officer or firefighter position is...
5 CFR 831.903 - Conditions for coverage in primary positions.
Code of Federal Regulations, 2012 CFR
2012-01-01
... positions. 831.903 Section 831.903 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE REGULATIONS (CONTINUED) RETIREMENT Law Enforcement Officers and Firefighters § 831.903 Conditions... the employing agency head to be a primary law enforcement officer or firefighter position is covered...
5 CFR 831.904 - Conditions for coverage in secondary positions.
Code of Federal Regulations, 2011 CFR
2011-01-01
... positions. 831.904 Section 831.904 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE REGULATIONS (CONTINUED) RETIREMENT Law Enforcement Officers and Firefighters § 831.904 Conditions... by the employing agency head to be a secondary law enforcement officer or firefighter position is...
5 CFR 831.904 - Conditions for coverage in secondary positions.
Code of Federal Regulations, 2012 CFR
2012-01-01
... positions. 831.904 Section 831.904 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE REGULATIONS (CONTINUED) RETIREMENT Law Enforcement Officers and Firefighters § 831.904 Conditions... by the employing agency head to be a secondary law enforcement officer or firefighter position is...
5 CFR 831.903 - Conditions for coverage in primary positions.
Code of Federal Regulations, 2014 CFR
2014-01-01
... positions. 831.903 Section 831.903 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE REGULATIONS (CONTINUED) RETIREMENT Law Enforcement Officers and Firefighters § 831.903 Conditions... the employing agency head to be a primary law enforcement officer or firefighter position is covered...
5 CFR 831.904 - Conditions for coverage in secondary positions.
Code of Federal Regulations, 2014 CFR
2014-01-01
... positions. 831.904 Section 831.904 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE REGULATIONS (CONTINUED) RETIREMENT Law Enforcement Officers and Firefighters § 831.904 Conditions... by the employing agency head to be a secondary law enforcement officer or firefighter position is...
5 CFR 831.903 - Conditions for coverage in primary positions.
Code of Federal Regulations, 2011 CFR
2011-01-01
... positions. 831.903 Section 831.903 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE REGULATIONS (CONTINUED) RETIREMENT Law Enforcement Officers and Firefighters § 831.903 Conditions... the employing agency head to be a primary law enforcement officer or firefighter position is covered...
5 CFR 831.903 - Conditions for coverage in primary positions.
Code of Federal Regulations, 2013 CFR
2013-01-01
... positions. 831.903 Section 831.903 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE REGULATIONS (CONTINUED) RETIREMENT Law Enforcement Officers and Firefighters § 831.903 Conditions... the employing agency head to be a primary law enforcement officer or firefighter position is covered...
5 CFR 831.904 - Conditions for coverage in secondary positions.
Code of Federal Regulations, 2013 CFR
2013-01-01
... positions. 831.904 Section 831.904 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE REGULATIONS (CONTINUED) RETIREMENT Law Enforcement Officers and Firefighters § 831.904 Conditions... by the employing agency head to be a secondary law enforcement officer or firefighter position is...
46 CFR 151.50-81 - Special operating requirements for heat sensitive cargoes.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Special operating requirements for heat sensitive cargoes. 151.50-81 Section 151.50-81 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... § 151.50-81 Special operating requirements for heat sensitive cargoes. When table 151.05 refers to this...
46 CFR 151.50-81 - Special operating requirements for heat sensitive cargoes.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 5 2011-10-01 2011-10-01 false Special operating requirements for heat sensitive cargoes. 151.50-81 Section 151.50-81 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... § 151.50-81 Special operating requirements for heat sensitive cargoes. When table 151.05 refers to this...
46 CFR 151.50-81 - Special operating requirements for heat sensitive cargoes.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 5 2014-10-01 2014-10-01 false Special operating requirements for heat sensitive cargoes. 151.50-81 Section 151.50-81 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... § 151.50-81 Special operating requirements for heat sensitive cargoes. When table 151.05 refers to this...
46 CFR 151.50-81 - Special operating requirements for heat sensitive cargoes.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 5 2012-10-01 2012-10-01 false Special operating requirements for heat sensitive cargoes. 151.50-81 Section 151.50-81 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... § 151.50-81 Special operating requirements for heat sensitive cargoes. When table 151.05 refers to this...
46 CFR 151.50-81 - Special operating requirements for heat sensitive cargoes.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 5 2013-10-01 2013-10-01 false Special operating requirements for heat sensitive cargoes. 151.50-81 Section 151.50-81 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... § 151.50-81 Special operating requirements for heat sensitive cargoes. When table 151.05 refers to this...
Risk factors for latex allergy in patients with spina bifida and latex sensitization.
Bernardini, R; Novembre, E; Lombardi, E; Mezzetti, P; Cianferoni, A; Danti, D A; Mercurella, A; Vierucci, A
1999-05-01
Some subjects with spina bifida (SB) and latex sensitization (cutaneous and/or serum IgE) can have clinical reactions, while others may have no symptoms after the exposure to latex products. This study was carried out to determine the risk factors associated with latex allergy in patients affected with SB and latex sensitization. Fifty-nine consecutive subjects affected with SB, besides answering a questionnaire, underwent a skin-prick test (SPT) to latex and the determination of the specific serum IgE (RAST CAP) to latex. The total serum IgE concentration was determined and SPT to common aero- and food-allergens, skin tests (prick + prick) with fresh foods (kiwi, pear, orange, pineapple, tomato, banana) and RAST CAP to the same foods tested by the prick + prick technique, were also performed. Fifteen out of the 59 subjects (25%) were sensitized to latex according to the presence of IgE to latex detected by SPT (nine patients) and/or RAST CAP (13 patients). Five out of the 15 sensitized patients (33%) suffered from clinical reactions to latex (urticaria, conjunctivitis, angioedema, rhinitis, bronchial asthma) while they were using latex gloves and while inflating latex balloons. In the 15 sensitized patients, the presence of specific latex seric IgE > 3.5 kU/L (>/= class 3), a positive latex SPT, an elevated total serum IgE, and a positive prick + prick and/or a positive RAST CAP to foods, were significant (P < 0.05) risk factors associated with latex symptoms. The other factors tested (age, gender, months of intermittent bladder catheterization, surgical procedures, SPT reactivity and clinical reactions to aero-allergens and food-allergens, skin tests for fresh foods, positive RAST CAP to foods) were not significantly different in symptomatic and asymptomatic patients. Significant risk factors for symptoms to latex in patients with SB and latex sensitization were a presence of specific IgE to latex > 3.5 kU/L, a more frequent positive latex SPT, elevated total IgE, and one or more positive prick + prick and/or RAST CAP to fresh foods.
Sjoholm-Gomez de Liano, Carl; Soberon-Ventura, Vidal F; Salcedo-Villanueva, Guillermo; Santos-Palacios, Abril; Guerrero-Naranjo, Jose Luis; Fromow-Guerra, Jans; García-Aguirre, Gerardo; Morales-Canton, Virgilio; Velez-Montoya, Raul
2017-01-01
To assess the sensitivity, specificity, positive predictive value and negative predictive value of anterior chamber tap for the diagnosis of bacterial endophthalmitis on a population with high prevalence. Retrospective, single centre, case series study. We reviewed all medical records with clinical diagnosis of bacterial endophthalmitis in our hospital from January 1st, 2000 to December 31st 2014. From each record, we documented general demographic data, best corrected visual acuity and vitreous and aqueous tap microbiological results. All cases were further divided according to the endophthalmitis aetiology to perform individual calculations of sensitivity, specificity, positive predictive value, negative predictive value, accuracy and prevalence. We used the results of the vitreous tap as the gold standard for diagnosis of bacterial endophthalmitis. We excluded those records in which the aqueous and vitreous samples were not taken simultaneously or had an incomplete microbiological report. Significance were assessed with chi squared statistics, with an alpha value of 0.05 for statistical significance. A total of 190 cases fulfilled the inclusion/exclusion criteria. Positive culture rate from vitreous samples was 64.74%. Positive culture rate from aqueous sample was 32.11%. Bacteria isolated from aqueous samples matched those isolated from vitreous samples 78.68% of the time. The overall sensitivity was 38.21%, specificity: 75.51%, positive predictive value: 79.66%, negative predictive value: 32.74% ( p = 0.08). Subgroup analysis showed that anterior chamber taps in cases of post-surgical endophthalmitis had a moderate to low sensitivity (37.73%), high specificity (93%) and high positive predictive value (95%) ( p < 0.04). The sensitivity and specificity of anterior chamber tap are low and should not be used for critical therapeutic decisions in patients with suspected bacterial endophthalmitis. In cases of post-surgical endophthalmitis, the result of an anterior chamber tap could be used for therapeutic guidance, but only in conjunction with clinical presentation and in the absence of a better method for diagnosis.
Chen, Sam Li-Sheng; Hsu, Chen-Yang; Yen, Amy Ming-Fang; Young, Graeme P; Chiu, Sherry Yueh-Hsia; Fann, Jean Ching-Yuan; Lee, Yi-Chia; Chiu, Han-Mo; Chiou, Shu-Ti; Chen, Hsiu-Hsi
2018-06-01
Background: Despite age and sex differences in fecal hemoglobin (f-Hb) concentrations, most fecal immunochemical test (FIT) screening programs use population-average cut-points for test positivity. The impact of age/sex-specific threshold on FIT accuracy and colonoscopy demand for colorectal cancer screening are unknown. Methods: Using data from 723,113 participants enrolled in a Taiwanese population-based colorectal cancer screening with single FIT between 2004 and 2009, sensitivity and specificity were estimated for various f-Hb thresholds for test positivity. This included estimates based on a "universal" threshold, receiver-operating-characteristic curve-derived threshold, targeted sensitivity, targeted false-positive rate, and a colonoscopy-capacity-adjusted method integrating colonoscopy workload with and without age/sex adjustments. Results: Optimal age/sex-specific thresholds were found to be equal to or lower than the universal 20 μg Hb/g threshold. For older males, a higher threshold (24 μg Hb/g) was identified using a 5% false-positive rate. Importantly, a nonlinear relationship was observed between sensitivity and colonoscopy workload with workload rising disproportionately to sensitivity at 16 μg Hb/g. At this "colonoscopy-capacity-adjusted" threshold, the test positivity (colonoscopy workload) was 4.67% and sensitivity was 79.5%, compared with a lower 4.0% workload and a lower 78.7% sensitivity using 20 μg Hb/g. When constrained on capacity, age/sex-adjusted estimates were generally lower. However, optimizing age/-sex-adjusted thresholds increased colonoscopy demand across models by 17% or greater compared with a universal threshold. Conclusions: Age/sex-specific thresholds improve FIT accuracy with modest increases in colonoscopy demand. Impact: Colonoscopy-capacity-adjusted and age/sex-specific f-Hb thresholds may be useful in optimizing individual screening programs based on detection accuracy, population characteristics, and clinical capacity. Cancer Epidemiol Biomarkers Prev; 27(6); 704-9. ©2018 AACR . ©2018 American Association for Cancer Research.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giuseppe Palmiotti
In this work, the implementation of a collision history-based approach to sensitivity/perturbation calculations in the Monte Carlo code SERPENT is discussed. The proposed methods allow the calculation of the eects of nuclear data perturbation on several response functions: the eective multiplication factor, reaction rate ratios and bilinear ratios (e.g., eective kinetics parameters). SERPENT results are compared to ERANOS and TSUNAMI Generalized Perturbation Theory calculations for two fast metallic systems and for a PWR pin-cell benchmark. New methods for the calculation of sensitivities to angular scattering distributions are also presented, which adopts fully continuous (in energy and angle) Monte Carlo estimators.
van Doorn, H Rogier; Kinh, Nguyen van; Tuan, Ha Manh; Tuan, Tran Anh; Minh, Ngo Ngoc Quang; Bryant, Juliet E; Hang, Vu thi Ty; Uyen, Le thi Tham; Thinh, Le Quoc; Anh, Tran thi Ngoc; Lan, Nguyen Phu Huong; Trung, Nguyen Vu; Taylor, Walter; Merson, Laura; Wertheim, Heiman F L; Farrar, Jeremy; Wolbers, Marcel; Chau, Nguyen van Vinh; de Jong, Menno D
2012-05-01
Point-of-care (POC) diagnostic tests for influenza can considerably shorten the time to clinical decision making. An investigational POC test based on a multiplexed immunoassay was developed by Meso Scale Diagnostics, LLC (MSD), with the objective to make a more sensitive rapid test that can also subtype influenza A viruses (1977 H1, H3, and H5). Between February and November 2010, we conducted a prospective multicenter study at four hospitals in Vietnam and compared the performance of this test to that of the WHO/CDC real-time reverse transcriptase PCR (RT-PCR) on nasal and throat swab specimens from patients presenting with influenza-like illness. Five hundred sixty-three adults and children with a median age of 25 months were enrolled. Sensitivity and specificity of the test with combined results from nasal and throat swab samples were 74.0% (131/177) and 99.7% (351/352), respectively, compared to RT-PCR. The POC test was as sensitive for influenza virus B as for influenza virus A (74.4% [64/86] versus 73.6% [67/91]). The positivity rate was associated with lower cycle threshold values (a marker for higher viral loads), sample type (73.6% for nasal swab versus 52.4% for throat swab), and younger age. A total of 210 (18.7%) out of 1,126 MSD tests failed, and for 34 (6%) of patients, both test samples failed (these were excluded from the performance analysis). Subtyping could be assessed only for influenza virus A/H3N2, as 1977 H1N1 was not circulating at the time and no H5N1-infected patients were enrolled, and was successful only in 9/54 patients infected with H3 influenza virus who had a positive POC test result for influenza virus A. This novel POC test provided highly sensitive detection of influenza viruses A and B compared to the reported sensitivities of other rapid tests. However, 18.7% of tests failed for technical reasons and subtyping for H3 was poor. Drawbacks to the technology include the requirement for a dedicated reader instrument and the need for continual updating of subtyping antibodies within the test array.
Precise estimation of tropospheric path delays with GPS techniques
NASA Technical Reports Server (NTRS)
Lichten, S. M.
1990-01-01
Tropospheric path delays are a major source of error in deep space tracking. However, the tropospheric-induced delay at tracking sites can be calibrated using measurements of Global Positioning System (GPS) satellites. A series of experiments has demonstrated the high sensitivity of GPS to tropospheric delays. A variety of tests and comparisons indicates that current accuracy of the GPS zenith tropospheric delay estimates is better than 1-cm root-mean-square over many hours, sampled continuously at intervals of six minutes. These results are consistent with expectations from covariance analyses. The covariance analyses also indicate that by the mid-1990s, when the GPS constellation is complete and the Deep Space Network is equipped with advanced GPS receivers, zenith tropospheric delay accuracy with GPS will improve further to 0.5 cm or better.
Pownall, Jaycee D; Jahoda, Andrew; Hastings, Richard; Kerr, Linda
2011-05-01
The sexual development of young people with intellectual disabilities is a marker of their transition to adulthood and affects their sense of well being and identity. Cognitive impairments and a socially marginalized position increase dependence on their families to assist with sexual matters. In this study, the authors adopted a novel interpretive phenomenological analysis approach, asking 8 mothers to contrast their experience of supporting similarly aged siblings with and without intellectual disabilities. Acknowledgment of their nondisabled offspring's sexuality was demanded by increasing autonomy, whereas continuing dependence of the offspring with intellectual disabilities hindered mothers who were addressing this intensely private and sensitive issue with them. The topic of sexuality brought to the forefront mothers' fears about their offspring's ability to cope with the challenges of adulthood.
Single-protein nanomechanical mass spectrometry in real time
Hanay, M.S.; Kelber, S.; Naik, A.K.; Chi, D.; Hentz, S.; Bullard, E.C.; Colinet, E.; Duraffourg, L.; Roukes, M.L.
2012-01-01
Nanoelectromechanical systems (NEMS) resonators can detect mass with exceptional sensitivity. Previously, mass spectra from several hundred adsorption events were assembled in NEMS-based mass spectrometry using statistical analysis. Here, we report the first realization of single-molecule NEMS-based mass spectrometry in real time. As each molecule in the sample adsorbs upon the NEMS resonator, its mass and the position-of-adsorption are determined by continuously tracking two driven vibrational modes of the device. We demonstrate the potential of multimode NEMS-based mass spectrometry by analyzing IgM antibody complexes in real-time. NEMS-MS is a unique and promising new form of mass spectrometry: it can resolve neutral species, provides resolving power that increases markedly for very large masses, and allows acquisition of spectra, molecule-by-molecule, in real-time. PMID:22922541
Body position-dependent shift in odor percept present only for perithreshold odors.
Lundström, Johan N; Boyle, Julie A; Jones-Gotman, Marilyn
2008-01-01
We recently demonstrated that a supine position causes a decrease in olfactory sensitivity compared with an upright position. We pursued that initial finding in 3 separate experiments in which we explored the extent of, and mechanism underlying, this phenomenon. In Experiment 1, we replicated the decrease in olfactory sensitivity when in a supine compared with an upright position. In Experiment 2, we measured body position-dependent shifts in physiological variables and sniff measures while smelling suprathreshold odorants and performing a perithreshold odor intensity discrimination task. Olfactory performances were reduced while supine. However, no relationships between the shift in olfactory performances and either the physiological variables or sniff measures were found. In Experiment 3, we determined that there were no position-dependent shifts in ability to discriminate or identify suprathreshold odors or rate them for pleasantness, intensity, or familiarity. However, a drop in scores was observed, and performance was slowed, on a cognitive skill while supine. These results demonstrate a body position-dependent shift in olfactory sensitivity only for perithreshold odors that appears to be mediated by cognitive rather than physiological factors. Implications for olfactory imaging studies are discussed.
Smith, Cynthia L.; Spinrad, Tracy L.; Eisenberg, Nancy; Gaertner, Bridget M.; Popp, Tierney K.; Maxon, Elizabeth
2007-01-01
SYNOPSIS Objective Longitudinal associations among maternal personality, emotional expressions, and parenting were examined. Design Maternal parenting (sensitivity and intrusiveness) and positive emotional expressions were observed during a free-play session with toddlers at 18 (T1, n = 246) and 30 (T3, n = 216) months. Mothers completed a personality measure at T1 and a questionnaire measuring their emotional expressiveness (positive and negative) when toddlers were 24 months old (T2, n = 213). Results Dimensions of maternal personality and maternal emotional expressiveness were related to individual differences in maternal parenting behaviors, in particular to maternal sensitivity. Conscientiousness and Agreeableness at T1 were positively associated with observed positive emotional expressions at T1. Agreeableness, Openness to Experience, and Extraversion at T1 also were positively related to positive emotional expressions reported by mothers at T2. Maternal positive emotional expressions (T1 and T2), in turn, were associated with more sensitive behavior observed with toddlers at T3. Conclusion In addition to direct effects of maternal personality on maternal parenting, mothers’ emotional expressiveness was found to be a possible pathway for explaining relations of maternal personality and parenting. PMID:18174914
Establishing a malaria diagnostics centre of excellence in Kisumu, Kenya.
Ohrt, Colin; Obare, Peter; Nanakorn, Ampon; Adhiambo, Christine; Awuondo, Ken; O'Meara, Wendy Prudhomme; Remich, Shon; Martin, Kurt; Cook, Earnest; Chretien, Jean-Paul; Lucas, Carmen; Osoga, Joseph; McEvoy, Peter; Owaga, Martin Lucas; Odera, James Sande; Ogutu, Bernhards
2007-06-12
Malaria microscopy, while the gold standard for malaria diagnosis, has limitations. Efficacy estimates in drug and vaccine malaria trials are very sensitive to small errors in microscopy endpoints. This fact led to the establishment of a Malaria Diagnostics Centre of Excellence in Kisumu, Kenya. The primary objective was to ensure valid clinical trial and diagnostic test evaluations. Key secondary objectives were technology transfer to host countries, establishment of partnerships, and training of clinical microscopists. A twelve-day "long" and a four-day "short" training course consisting of supervised laboratory practicals, lectures, group discussions, demonstrations, and take home assignments were developed. Well characterized slides were developed and training materials iteratively improved. Objective pre- and post-course evaluations consisted of 30 slides (19 negative, 11 positive) with a density range of 50-660 parasites/mul, a written examination (65 questions), a photographic image examination (30 images of artifacts and species specific characteristics), and a parasite counting examination. To date, 209 microscopists have participated from 11 countries. Seventy-seven experienced microscopists participated in the "long" courses, including 47 research microscopists. Sensitivity improved by a mean of 14% (CI 9-19%) from 77% baseline (CI 73-81 %), while specificity improved by a mean of 17% (CI 11-23%) from 76% (CI 70-82%) baseline. Twenty-three microscopists who had been selected for a four-day refresher course showed continued improvement with a mean final sensitivity of 95% (CI 91-98%) and specificity of 97% (CI 95-100%). Only 9% of those taking the pre-test in the "long" course achieved a 90% sensitivity and 95% specificity, which increased to 61% of those completing the "short" course. All measures of performance improved substantially across each of the five organization types and in each course offered. The data clearly illustrated that false positive and negative malaria smears are a serious problem, even with research microscopists. Training dramatically improved performance. Quality microscopy can be provided by the Centre of Excellence concept. This concept can be extended to other diagnostics of public health importance, and comprehensive disease control strategies.
Establishing a malaria diagnostics centre of excellence in Kisumu, Kenya
Ohrt, Colin; Obare, Peter; Nanakorn, Ampon; Adhiambo, Christine; Awuondo, Ken; O'Meara, Wendy Prudhomme; Remich, Shon; Martin, Kurt; Cook, Earnest; Chretien, Jean-Paul; Lucas, Carmen; Osoga, Joseph; McEvoy, Peter; Owaga, Martin Lucas; Odera, James Sande; Ogutu, Bernhards
2007-01-01
Background Malaria microscopy, while the gold standard for malaria diagnosis, has limitations. Efficacy estimates in drug and vaccine malaria trials are very sensitive to small errors in microscopy endpoints. This fact led to the establishment of a Malaria Diagnostics Centre of Excellence in Kisumu, Kenya. The primary objective was to ensure valid clinical trial and diagnostic test evaluations. Key secondary objectives were technology transfer to host countries, establishment of partnerships, and training of clinical microscopists. Case description A twelve-day "long" and a four-day "short" training course consisting of supervised laboratory practicals, lectures, group discussions, demonstrations, and take home assignments were developed. Well characterized slides were developed and training materials iteratively improved. Objective pre- and post-course evaluations consisted of 30 slides (19 negative, 11 positive) with a density range of 50–660 parasites/μl, a written examination (65 questions), a photographic image examination (30 images of artifacts and species specific characteristics), and a parasite counting examination. Discussion and Evaluation To date, 209 microscopists have participated from 11 countries. Seventy-seven experienced microscopists participated in the "long" courses, including 47 research microscopists. Sensitivity improved by a mean of 14% (CI 9–19%) from 77% baseline (CI 73–81 %), while specificity improved by a mean of 17% (CI 11–23%) from 76% (CI 70–82%) baseline. Twenty-three microscopists who had been selected for a four-day refresher course showed continued improvement with a mean final sensitivity of 95% (CI 91–98%) and specificity of 97% (CI 95–100%). Only 9% of those taking the pre-test in the "long" course achieved a 90% sensitivity and 95% specificity, which increased to 61% of those completing the "short" course. All measures of performance improved substantially across each of the five organization types and in each course offered. Conclusion The data clearly illustrated that false positive and negative malaria smears are a serious problem, even with research microscopists. Training dramatically improved performance. Quality microscopy can be provided by the Centre of Excellence concept. This concept can be extended to other diagnostics of public health importance, and comprehensive disease control strategies. PMID:17565676
ERIC Educational Resources Information Center
Pluess, Michael; Assary, Elham; Lionetti, Francesca; Lester, Kathryn J.; Krapohl, Eva; Aron, Elaine N.; Aron, Arthur
2018-01-01
A large number of studies document that children differ in the degree they are shaped by their developmental context with some being more sensitive to environmental influences than others. Multiple theories suggest that "Environmental Sensitivity" is a common trait predicting the response to negative as well as positive exposures.…
Gasquet, Isabelle; Tcherny-Lessenot, Stéphanie; Lépine, Jean-Pierre; Falissard, Bruno
2006-12-01
To see if patient satisfaction with psychotropics (PSP) could be used as a patient-oriented outcome variable in the evaluation of PSP drugs in clinical epidemiological studies, relationships between PSP, clinical status, QoL, compliance and the type of antipsychotic were analyzed. Elements of validation of PSP were also assessed. In a 6-month prospective study, 933 schizophrenic outpatients with initiation or change to their antipsychotic treatment were enrolled. Psychiatrists completed five CGI-SCH scales (positive, negative, cognitive, depressive and global), hospitalization, compliance, and prescription variables. Patients completed PSP, EuroQoL scales, sexual function and compliance variables. A satisfactory structural equation model was obtained showing significant relationships PSP/compliance (coef.=0.16), QoL/PSP (coef.=0.37), clinical status/QoL (coef.=0.61), clinical status/compliance (coef.=0.09). Patients receiving olanzapine were more satisfied than patients receiving other atypicals (coef.=012) and had better clinical status than patients treated with typicals (coef.=0.08). Evolution of PSP was related to clinical status, QoL, and continuation of treatment (all P<001). Sensitivity to change of PSP was moderate (effect size=0.2). PSP produced consistent results in relation to validated outcome variables. However, a single-item measure was not sufficiently sensitive to change. Multi-item questionnaires evaluating different dimensions are needed.
NanoSQUIDs: Basics & recent advances
NASA Astrophysics Data System (ADS)
José Martínez-Pérez, Maria; Koelle, Dieter
2017-08-01
Superconducting Quantum Interference Devices (SQUIDs) are one of the most popular devices in superconducting electronics. They combine the Josephson effect with the quantization of magnetic flux in superconductors. This gives rise to one of the most beautiful manifestations of macroscopic quantum coherence in the solid state. In addition, SQUIDs are extremely sensitive sensors allowing us to transduce magnetic flux into measurable electric signals. As a consequence, any physical observable that can be converted into magnetic flux, e.g., current, magnetization, magnetic field or position, becomes easily accessible to SQUID sensors. In the late 1980s it became clear that downsizing the dimensions of SQUIDs to the nanometric scale would encompass an enormous increase of their sensitivity to localized tiny magnetic signals. Indeed, nanoSQUIDs opened the way to the investigation of, e.g., individual magnetic nanoparticles or surface magnetic states with unprecedented sensitivities. The purpose of this chapter is to present a detailed survey of microscopic and nanoscopic SQUID sensors. We will start by discussing the principle of operation of SQUIDs, placing the emphasis on their application as ultrasensitive detectors for small localized magnetic signals. We will continue by reviewing a number of existing devices based on different kinds of Josephson junctions and materials, focusing on their advantages and drawbacks. The last sections are left for applications of nanoSQUIDs in the fields of scanning SQUID microscopy and magnetic particle characterization, placing special stress on the investigation of individual magnetic nanoparticles.
Fournier, Marjorie; Zhang, Yi; Wildschut, Janine D.; Dolla, Alain; Voordouw, Johanna K.; Schriemer, David C.; Voordouw, Gerrit
2003-01-01
Two mutant strains of Desulfovibrio vulgaris Hildenborough lacking either the sod gene for periplasmic superoxide dismutase or the rbr gene for rubrerythrin, a cytoplasmic hydrogen peroxide (H2O2) reductase, were constructed. Their resistance to oxidative stress was compared to that of the wild-type and of a sor mutant lacking the gene for the cytoplasmic superoxide reductase. The sor mutant was more sensitive to exposure to air or to internally or externally generated superoxide than was the sod mutant, which was in turn more sensitive than the wild-type strain. No obvious oxidative stress phenotype was found for the rbr mutant, indicating that H2O2 resistance may also be conferred by two other rbr genes in the D. vulgaris genome. Inhibition of Sod activity by azide and H2O2, but not by cyanide, indicated it to be an iron-containing Sod. The positions of Fe-Sod and Sor were mapped by two-dimensional gel electrophoresis (2DE). A strong decrease of Sor in continuously aerated cells, indicated by 2DE, may be a critical factor in causing cell death of D. vulgaris. Thus, Sor plays a key role in oxygen defense of D. vulgaris under fully aerobic conditions, when superoxide is generated mostly in the cytoplasm. Fe-Sod may be more important under microaerophilic conditions, when the periplasm contains oxygen-sensitive, superoxide-producing targets. PMID:12486042
The EVE Doppler Sensitivity and Flare Observations
NASA Technical Reports Server (NTRS)
Hudson, H. S.; Woods, T. N.; Chamberlin, P. C.; Didkovsky, L.; Del Zanna, G.
2011-01-01
The Extreme-ultraviolet Variability Experiment (EVE) obtains continuous EUV spectra of the Sun viewed as a star. Its primary objective is the characterization of solar spectral irradiance, but its sensitivity and stability make it extremely interesting for observations of variability on time scales down to the limit imposed by its basic 10 s sample interval. In this paper we characterize the Doppler sensitivity of the EVE data. We find that the 30.4 nm line of He II has a random Doppler error below 0.001 nm (1 pm, better than 10 km/s as a redshift), with ample stability to detect the orbital motion of its satellite, the Solar Dynamics Observatory (SDO). Solar flares also displace the spectrum, both because of Doppler shifts and because of EVE's optical layout, which (as with a slitless spectrograph) confuses position and wavelength. As a flare develops, the centroid of the line displays variations that reflect Doppler shifts and therefore flare dynamics. For the impulsive phase of the flare SOL2010-06-12, we find the line centroid to have a redshift of 16.8 +/- 5.9 km/s relative to that of the flare gradual phase (statistical errors only). We find also that high-temperature lines, such as Fe XXIV 19.2 nm, have well-determined Doppler components for major flares, with decreasing apparent blueshifts as expected from chromospheric evaporation flows.
Development of a sensitivity analysis technique for multiloop flight control systems
NASA Technical Reports Server (NTRS)
Vaillard, A. H.; Paduano, J.; Downing, D. R.
1985-01-01
This report presents the development and application of a sensitivity analysis technique for multiloop flight control systems. This analysis yields very useful information on the sensitivity of the relative-stability criteria of the control system, with variations or uncertainties in the system and controller elements. The sensitivity analysis technique developed is based on the computation of the singular values and singular-value gradients of a feedback-control system. The method is applicable to single-input/single-output as well as multiloop continuous-control systems. Application to sampled-data systems is also explored. The sensitivity analysis technique was applied to a continuous yaw/roll damper stability augmentation system of a typical business jet, and the results show that the analysis is very useful in determining the system elements which have the largest effect on the relative stability of the closed-loop system. As a secondary product of the research reported here, the relative stability criteria based on the concept of singular values were explored.
Amoxicillin rash in patients with infectious mononucleosis: evidence of true drug sensitization.
Ónodi-Nagy, Katinka; Kinyó, Ágnes; Meszes, Angéla; Garaczi, Edina; Kemény, Lajos; Bata-Csörgő, Zsuzsanna
2015-01-01
It hasn't been clearly understood yet whether sensitization to antibiotics, the virus itself or transient loss of drug tolerance due to the virus, is responsible for the development of maculopapular exanthems following amoxicillin intake in patients with infectious mononucleosis. We aimed to examine whether sensitization to penicillin developed among patients with skin rash following amoxicillin treatment within infectious mononucleosis. Ten patients were investigated for drug sensitization by lymphocyte transformation test and six patients were further tested by prick-, intradermal and patch tests employing the penicillin's main antigens. Lymphocyte transformation test showed negative results with amoxicillin, while one patient had positive reaction to cefixime. Six patients with suspected sensitization to amoxicillin were then investigated by in vivo tests. Prick tests were negative in all six patients, but the intradermal tests showed positive reactions in four patients. Our data demonstrate that in vitro testing is not sensitive enough in determining drug sensitization to penicillin. In vivo tests should be performed to detect sensitization and indeed with skin tests our results confirmed that sensitization to aminopenicillin may develop within infectious mononucleosis.
Agger, W A; Maki, D G
1978-01-01
A preponderance of clusters seen on direct Gram stain of blood cultures positive for gram-positive cocci was 98% sensitive and 100% specific for identification of staphylococcal species or of Peptococcus. A preponderance of chains, pairs, or both was 100% sensitive and 98% specific for identifying streptococci. Further presumptive identification of either staphylococci or streptococci based on microscopic morphology was unreliable. The direct Gram stain is highly reliable for differentiating staphylococci from streptococci and should be of considerable value to clinicians selecting initial antimicrobial therapy. PMID:75888
Sensitivity of GRETINA position resolution to hole mobility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prasher, V. S.; Cromaz, M.; Merchan, E.
The sensitivity of the position resolution of the gamma-ray tracking array GRETINA to the hole charge-carrier mobility parameter is investigated. The χ 2 results from a fit of averaged signal (“superpulse”) data exhibit a shallow minimum for hole mobilities 15% lower than the currently adopted values. Calibration data on position resolution is analyzed, together with simulations that isolate the hole mobility dependence of signal decomposition from other effects such as electronics cross-talk. Our results effectively exclude hole mobility as a dominant parameter for improving the position resolution for reconstruction of gamma-ray interaction points in GRETINA.
Sensitivity of GRETINA position resolution to hole mobility
Prasher, V. S.; Cromaz, M.; Merchan, E.; ...
2017-02-01
The sensitivity of the position resolution of the gamma-ray tracking array GRETINA to the hole charge-carrier mobility parameter is investigated. The χ 2 results from a fit of averaged signal (“superpulse”) data exhibit a shallow minimum for hole mobilities 15% lower than the currently adopted values. Calibration data on position resolution is analyzed, together with simulations that isolate the hole mobility dependence of signal decomposition from other effects such as electronics cross-talk. Our results effectively exclude hole mobility as a dominant parameter for improving the position resolution for reconstruction of gamma-ray interaction points in GRETINA.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Regulations Relating to Transportation (Continued) TRANSPORTATION SECURITY ADMINISTRATION, DEPARTMENT OF HOMELAND SECURITY SECURITY RULES FOR ALL MODES OF TRANSPORTATION PROTECTION OF SENSITIVE SECURITY... of records and information that TSA has determined to be Sensitive Security Information, as defined...
Detection of immunocytological markers in photomicroscopic images
NASA Astrophysics Data System (ADS)
Friedrich, David; zur Jacobsmühlen, Joschka; Braunschweig, Till; Bell, André; Chaisaowong, Kraisorn; Knüchel-Clarke, Ruth; Aach, Til
2012-03-01
Early detection of cervical cancer can be achieved through visual analysis of cell anomalies. The established PAP smear achieves a sensitivity of 50-90%, most false negative results are caused by mistakes in the preparation of the specimen or reader variability in the subjective, visual investigation. Since cervical cancer is caused by human papillomavirus (HPV), the detection of HPV-infected cells opens new perspectives for screening of precancerous abnormalities. Immunocytochemical preparation marks HPV-positive cells in brush smears of the cervix with high sensitivity and specificity. The goal of this work is the automated detection of all marker-positive cells in microscopic images of a sample slide stained with an immunocytochemical marker. A color separation technique is used to estimate the concentrations of the immunocytochemical marker stain as well as of the counterstain used to color the nuclei. Segmentation methods based on Otsu's threshold selection method and Mean Shift are adapted to the task of segmenting marker-positive cells and their nuclei. The best detection performance of single marker-positive cells was achieved with the adapted thresholding method with a sensitivity of 95.9%. The contours differed by a modified Hausdorff Distance (MHD) of 2.8 μm. Nuclei of single marker positive cells were detected with a sensitivity of 95.9% and MHD = 1.02 μm.
Esfahlani, Farnaz Zamani; Sayama, Hiroki; Visser, Katherine Frost; Strauss, Gregory P
2017-12-01
Objective: The Positive and Negative Syndrome Scale is a primary outcome measure in clinical trials examining the efficacy of antipsychotic medications. Although the Positive and Negative Syndrome Scale has demonstrated sensitivity as a measure of treatment change in studies using traditional univariate statistical approaches, its sensitivity to detecting network-level changes in dynamic relationships among symptoms has yet to be demonstrated using more sophisticated multivariate analyses. In the current study, we examined the sensitivity of the Positive and Negative Syndrome Scale to detecting antipsychotic treatment effects as revealed through network analysis. Design: Participants included 1,049 individuals diagnosed with psychotic disorders from the Phase I portion of the Clinical Antipsychotic Trials of Intervention Effectiveness (CATIE) study. Of these participants, 733 were clinically determined to be treatment-responsive and 316 were found to be treatment-resistant. Item level data from the Positive and Negative Syndrome Scale were submitted to network analysis, and macroscopic, mesoscopic, and microscopic network properties were evaluated for the treatment-responsive and treatment-resistant groups at baseline and post-phase I antipsychotic treatment. Results: Network analysis indicated that treatment-responsive patients had more densely connected symptom networks after antipsychotic treatment than did treatment-responsive patients at baseline, and that symptom centralities increased following treatment. In contrast, symptom networks of treatment-resistant patients behaved more randomly before and after treatment. Conclusions: These results suggest that the Positive and Negative Syndrome Scale is sensitive to detecting treatment effects as revealed through network analysis. Its findings also provide compelling new evidence that strongly interconnected symptom networks confer an overall greater probability of treatment responsiveness in patients with psychosis, suggesting that antipsychotics achieve their effect by enhancing a number of central symptoms, which then facilitate reduction of other highly coupled symptoms in a network-like fashion.
Persy, B; Ieven, M
2013-01-01
Peritonitis related to peritoneal dialysis increases morbidity and mortality and is the main reason for switching to haemodialysis. In this study, we analysed the dialysate of 164 peritoneal dialysis patients that was sent to our laboratory between January 2005 and August 2009. There were 196 peritonitis episodes identified in 78 patients. For all episodes, microbial aetiologies and in-vitro antimicrobial sensitivities were determined in addition to parameters such as the leukocyte count (WBC) and the result of the Gram stain. Results in children were analysed separately because of previously described differences in aetiology. In both groups, Gram positives were most commonly isolated, followed by Gram negatives and fungi or yeasts. In children, the proportion of coagulase-negative staphylococci compared to S. aureus is smaller than in adults. Gram stain showed predominant morphotypes concordant with culture results in 28% of episodes. A significant difference in WBC count was found between culture-positive (mean=3117 x 10(9)/L) and culture-negative (mean=981 x 10(9)/L) episodes in adults (p=0.001). The WBC count in episodes caused exclusively by CNS (mean=1502x10(9)/L) was also on average significantly lower (p=0.001) compared to all culture positive episodes. Resistance to methicillin was registered in 33% of cultures, positive for staphylococci. All Gram-positives were sensitive to vancomycin. Coverage of Gram-negatives by ceftazidim and quinolones was excellent (89%). Based on local sensitivity data and known characteristics of antimicrobials, a first-line empirical combination of intraperitoneal vancomycin with orally administered ciprofloxacin seems indicated in our population. Pathogens of positive aerobic cultures were sensitive in-vitro to their combined antimicrobial effect in 90% of cases.
The utility of serum tryptase in the diagnosis of food-induced anaphylaxis.
Wongkaewpothong, Patcharaporn; Pacharn, Punchama; Sripramong, Chaweewan; Boonchoo, Siribangon; Piboonpocanun, Surapon; Visitsunthorn, Nualanong; Vichyanond, Pakit; Jirapongsananuruk, Orathai
2014-07-01
This study investigates the utility of serum tryptase for the confirmation of shrimp-induced anaphylaxis. Patients with a history of shrimp allergy and positive skin prick tests (SPT) to commercial shrimp extract were recruited for shrimp challenges. Serum total tryptase was obtained at baseline and 60 min (peak) after the onset of symptoms. Thirty-nine patients were challenged. There were 12 patients with anaphylaxis, 20 with mild reactions and 7 without symptoms (control group). Characteristic features and baseline tryptase were not different among the 3 groups. The peak tryptase levels were higher than the baseline in anaphylaxis and mild reaction groups (P<0.05). The delta-tryptase (peak minus baseline) and the tryptase ratio (peak divided by baseline) in the anaphylaxis group were higher than the mild reaction and control groups (P<0.01). The optimum cut-off for peak tryptase to confirm anaphylaxis was 2.99 µg/L with 50% sensitivity, 85% specificity, 3.33 positive likelihood ratio (LR) and 0.59 negative LR. The manufacturer's cut-off for peak tryptase was >11.4 µg/L with 17% sensitivity, 100% specificity, infinity positive LR and 0.83 negative LR. The best cut-off for delta-tryptase was ≥0.8 µg/L with 83% sensitivity, 93% specificity, 11.86 positive LR and 0.18 negative LR. The best cut-off for tryptase ratio was ≥1.5 with 92% sensitivity, 96% specificity, 23 positive LR and 0.08 negative LR. The peak tryptase level should be compared with the baseline value to confirm anaphylaxis. The tryptase ratio provide the best sensitivity, specificity, positive and negative LR than a single peak serum tryptase for the confirmation of shrimp-induced anaphylaxis.
Arita, Minetaro; Ling, Hua; Yan, Dongmei; Nishimura, Yorihiro; Yoshida, Hiromu; Wakita, Takaji; Shimizu, Hiroyuki
2009-12-16
In the global eradication program for poliomyelitis, the laboratory diagnosis plays a critical role by isolating poliovirus (PV) from the stool samples of acute flaccid paralysis (AFP) cases. In this study, we developed a reverse transcription-loop-mediated isothermal amplification (RT-LAMP) system for a rapid and highly sensitive detection of enterovirus including PV to identify stool samples positive for enterovirus including PV. A primer set was designed for RT-LAMP to detect enterovirus preferably those with PV-like 5'NTRs of the viral genome. The sensitivity of RT-LAMP system was evaluated with prototype strains of enterovirus. Detection of enterovirus from stool extracts was examined by using RT-LAMP system. We detected at least 400 copies of the viral genomes of PV(Sabin) strains within 90 min by RT-LAMP with the primer set. This RT-LAMP system showed a preference for Human enterovirus species C (HEV-C) strains including PV, but exhibited less sensitivity to the prototype strains of HEV-A and HEV-B (detection limits of 7,400 to 28,000 copies). Stool extracts, from which PV, HEV-C, or HEV-A was isolated in the cell culture system, were mostly positive by RT-LAMP method (positive rates of 15/16 (= 94%), 13/14 (= 93%), and 4/4 (= 100%), respectively). The positive rate of this RT-LAMP system for stool extracts from which HEV-B was isolated was lower than that of HEV-C (positive rate of 11/21 (= 52%)). In the stool samples, which were negative for enterovirus isolation by the cell culture system, we found that two samples were positive for RT-LAMP (positive rates of 2/38 (= 5.3%)). In these samples, enterovirus 96 was identified by sequence analysis utilizing a seminested PCR system. RT-LAMP system developed in this study showed a high sensitivity comparable to that of the cell culture system for the detection of PV, HEV-A, and HEV-C, but less sensitivity to HEV-B. This RT-LAMP system would be useful for the direct detection of enterovirus from the stool extracts.
[Sensitivity and antibiotic resistance in infections of the musculoskeletal system].
Mata-Hernández, Argenis; Rivera-Villa, Adrián Huematzin; Miguel-Pérez, Adrián; Pérez-Atanasio, José Manuel; Torres-González, Rubén
2016-01-01
Infections of the musculoskeletal system are a devastating complication for patients, due to it's long rehabilitation process and even sometimes the removal of the implant, the chronicity of infection, is often due to lack of coverage in empirical antibiotics. A retrospective, observational, descriptive cohort study was performed. All cultures form musculoskeletal system infected patients reported of sensitivity and resistance of germs isolated were analyzed. A total of 143 positive results were included. Reported more frequent germ Staphylococcus aureus accounted for 75 positive cases, followed by Escherichia coli with 31 positive results. Antibiotics with better sensitivity according to the type of microorganisms were trimethoprim-sulfamethoxazole and vancomycin, levofloxacin and linezolid, gentamicin, erythromycin and amikacin. Regarding antibiotic resistance, those reported with the highest percentage were penicillin G, amoxicillin with clavulanic acid and ampicillin. We recommend using empirical treatments in musculoskeletal system infections, trimethoprim-sulfamethoxazole are the best choice because they have the same sensitivity compare with vancomycin and a resistance rate of 7.6%. Betalactamics have a high percentage of resistance and low sensitivity so we must consider alternatives.
Rao, Gottipaty N; Karpf, Andreas
2010-09-10
A trace gas sensor for the detection of nitrogen dioxide based on cavity ringdown spectroscopy (CRDS) and a continuous wave external cavity tunable quantum cascade laser operating at room temperature has been designed, and its features and performance characteristics are reported. By measuring the ringdown times of the cavity at different concentrations of NO(2), we report a sensitivity of 1.2 ppb for the detection of NO(2) in Zero Air.
The Case for Frequency Sensitivity in Orthographic Learning
ERIC Educational Resources Information Center
McMurray, Sharon; McVeigh, Claire
2016-01-01
This paper positions the importance of frequency sensitivity in the development of orthographic knowledge throughout childhood and promotes learning to spell as a vehicle which may be used effectively to develop this sensitivity. It is suggested that orthographic knowledge is advanced via a process of "frequency sensitivity" to…
Continuous-Flow Detector for Rapid Pathogen Identification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barrett, Louise M.; Skulan, Andrew J.; Singh, Anup K.
2006-09-01
This report describes the continued development of a low-power, portable detector for the rapid identification of pathogens such as B. anthracis and smallpox. Based on our successful demonstration of the continuous filter/concentrator inlet, we believe strongly that the inlet section will enable differentiation between viable and non-viable populations, between types of cells, and between pathogens and background contamination. Selective, continuous focusing of particles in a microstream enables highly selective and sensitive identification using fluorescently labeled antibodies and other receptors such as peptides, aptamers, or small ligands to minimize false positives. Processes such as mixing and lysing will also benefit frommore » the highly localized particle streams. The concentrator is based on faceted prisms to contract microfluidic flows while maintaining uniform flowfields. The resulting interfaces, capable of high throughput, serve as high-, low-, and band-pass filters to direct selected bioparticles to a rapid, affinity-based detection system. The proposed device is superior to existing array-based detectors as antibody-pathogen binding can be accomplished in seconds rather than tens of minutes or even hours. The system is being designed to interface with aerosol collectors under development by the National Laboratories or commercial systems. The focused stream is designed to be interrogated using diode lasers to differentiate pathogens by light scattering. Identification of particles is done using fluorescently labeled antibodies to tag the particles, followed by multiplexed laser-induced fluorescence (LIF) detection (achieved by labeling each antibody with a different dye).« less
Pre- and post-treatment ultrasonography in hypothyroid dogs.
Taeymans, Olivier; Daminet, Sylvie; Duchateau, Luc; Saunders, Jimmy H
2007-01-01
Primary hypothyroidism is a frequent endocrine disorder in the adult dog. However, false-positive diagnoses are common because of the relatively low accuracy of most commonly used biochemical tests. The purpose of this study was to describe the ultrasonographic features of the thyroid gland in hypothyroid dogs, to calculate the diagnostic sensitivity of gray-scale ultrasound using a combination of clinical symptoms and biochemical thyroid tests as gold standard, and to investigate the evolution of the ultrasonographic features after treatment of hypothyroidism. Eighteen dogs were studied prospectively. All dogs underwent an ultrasound examination at first presentation and 13 underwent one or two additional ultrasound examinations over time. At first presentation, a sensitivity of 76.5% (95% CI [50.0-93.0% 1) for decreased echogenicity, 64.7% (95% CI [38.385.8% 1) for inhomogeneity, 70.6% (95% CI 144.0-89.7%]) for irregular capsule delineation, 64.7% (95% CI [38.3-85.8%]) for abnormal lobe shape and 47.1% (95% CI 123.0-72.2%]) for decreased relative thyroid volume was obtained. Combining these five parameters together resulted in an overall sensitivity of 94.1% (95% CI [71.3-99.9%]) for gray-scale ultrasound in the detection of acquired hypothyroidism at first presentation. A continuous decrease of thyroid volume was seen over time after treatment, while the other investigated parameters did not change significantly during the follow-up period. None of the thyroid glands were considered normal at the last presentation. Grayscale ultrasound is a sensitive and quick test for the diagnosis of primary hypothyroidism in dogs.
Absolute and angular efficiencies of a microchannel-plate position-sensitive detector
NASA Technical Reports Server (NTRS)
Gao, R. S.; Gibner, P. S.; Newman, J. H.; Smith, K. A.; Stebbings, R. F.
1984-01-01
This paper presents a characterization of a commercially available position-sensitive detector of energetic ions and neutrals. The detector consists of two microchannel plates followed by a resistive position-encoding anode. The work includes measurement of absolute efficiencies of H(+), He(+), and O(+) ions in the energy range between 250 and 5000 eV, measurement of relative detection efficiencies as a function of particle impact angle, and a simple method for accurate measurement of the time at which a particle strikes the detector.
Anger, H.O.; Martin, D.C.; Lampton, M.L.
1983-07-26
A radiation imaging system using a charge multiplier and a position sensitive anode in the form of periodically arranged sets of interconnected anode regions for detecting the position of the centroid of a charge cloud arriving thereat from the charge multiplier. Various forms of improved position sensitive anodes having single plane electrode connections are disclosed. Various analog and digital signal processing systems are disclosed, including systems which use the fast response of microchannel plates, anodes and preamps to perform scintillation pulse height analysis digitally. 15 figs.
Methods for increasing the sensitivity of gamma-ray imagers
Mihailescu, Lucian [Pleasanton, CA; Vetter, Kai M [Alameda, CA; Chivers, Daniel H [Fremont, CA
2012-02-07
Methods are presented that increase the position resolution and granularity of double sided segmented semiconductor detectors. These methods increase the imaging resolution capability of such detectors, either used as Compton cameras, or as position sensitive radiation detectors in imagers such as SPECT, PET, coded apertures, multi-pinhole imagers, or other spatial or temporal modulated imagers.
Systems for increasing the sensitivity of gamma-ray imagers
Mihailescu, Lucian; Vetter, Kai M.; Chivers, Daniel H.
2012-12-11
Systems that increase the position resolution and granularity of double sided segmented semiconductor detectors are provided. These systems increase the imaging resolution capability of such detectors, either used as Compton cameras, or as position sensitive radiation detectors in imagers such as SPECT, PET, coded apertures, multi-pinhole imagers, or other spatial or temporal modulated imagers.
ERIC Educational Resources Information Center
Crookes, Kate; Hayward, William G.
2012-01-01
Presenting a face inverted (upside down) disrupts perceptual sensitivity to the spacing between the features. Recently, it has been shown that this disruption is greater for vertical than horizontal changes in eye position. One explanation for this effect proposed that inversion disrupts the processing of long-range (e.g., eye-to-mouth distance)…
Muttamba, Winters; Ssengooba, Willy; Sekibira, Rogers; Kirenga, Bruce; Katamba, Achilles; Joloba, Moses
2018-01-01
Xpert MTB/RIF assay is a highly sensitive test for TB diagnosis, but still costly to most low-income countries. Several implementation strategies instead of frontline have been suggested; however with scarce data. We assessed accuracy of different Xpert MTB/RIF implementation strategies to inform national roll-out. This was a cross-sectional study of 1,924 adult presumptive TB patients in five regional referral hospitals of Uganda. Two sputum samples were collected, one for fluorescent microscopy (FM) and Xpert MTB/RIF examined at the study site laboratories. The second sample was sent to the Uganda Supra National TB reference laboratory for culture using both Lowenstein Jensen (LJ) and liquid culture (MGIT). We compared the sensitivities of FM, Xpert MTB/RIF and the incremental sensitivity of Xpert MTB/RIF among patients negative on FM using LJ and/or MGIT as a reference standard. A total 1924 patients were enrolled of which 1596 (83%) patients had at least one laboratory result and 1083 respondents had a complete set of all the laboratory results. A total of 328 (30%) were TB positive on LJ and /or MGIT culture. The sensitivity of FM was n (%; 95% confidence interval) 246 (63.5%; 57.9-68.7) overall compared to 52 (55.4%; 44.1-66.3) among HIV positive individuals, while the sensitivity of Xpert MTB/RIF was 300 (76.2%; 71.7-80.7) and 69 (71.6%; 60.5-81.1) overall and among HIV positive individuals respectively. Overall incremental sensitivity of Xpert MTB/RIF was 60 (36.5%; 27.7-46.0) and 20 (41.7%; 25.5-59.2) among HIV positive individuals. Xpert MTB/RIF has a higher sensitivity than FM both in general population and HIV positive population. Xpert MTB/RIF offers a significant increase in terms of diagnostic sensitivity even when it is deployed selectively i.e. among smear negative presumptive TB patients. Our results support frontline use of Xpert MTB/RIF assay in high HIV/TB prevalent countries. In settings with limited access, mechanisms to refer smear negative sputum samples to Xpert MTB/RIF hubs are recommended.
Cathcart, Stuart; Bhullar, Navjot; Immink, Maarten; Della Vedova, Chris; Hayball, John
2012-01-01
A central model for chronic tension-type headache (CTH) posits that stress contributes to headache, in part, by aggravating existing hyperalgesia in CTH sufferers. The prediction from this model that pain sensitivity mediates the relationship between stress and headache activity has not yet been examined. To determine whether pain sensitivity mediates the relationship between stress and prospective headache activity in CTH sufferers. Self-reported stress, pain sensitivity and prospective headache activity were measured in 53 CTH sufferers recruited from the general population. Pain sensitivity was modelled as a mediator between stress and headache activity, and tested using a nonparametric bootstrap analysis. Pain sensitivity significantly mediated the relationship between stress and headache intensity. The results of the present study support the central model for CTH, which posits that stress contributes to headache, in part, by aggravating existing hyperalgesia in CTH sufferers. Implications for the mechanisms and treatment of CTH are discussed.
Moon, In Kyu; Ki, Bugeun; Yoon, Seonno; Oh, Jungwoo
2016-01-01
Lightweight, simple and flexible self-powered photodetectors are urgently required for the development and application of advanced optical systems for the future of wearable electronic technology. Here, using a low-temperature reduction process, we report a chemical approach for producing freestanding monolithic reduced graphene oxide papers with different gradients of the carbon/oxygen concentration ratio. We also demonstrate a novel type of freestanding monolithic reduced graphene oxide self-powered photodetector based on a symmetrical metal–semiconductor–metal structure. Upon illumination by a 633-nm continuous wave laser, the lateral photovoltage is observed to vary linfearly with the laser position between two electrodes on the reduced graphene oxide surface. This result may suggest that the lateral photovoltaic effect in the reduced graphene oxide film originates from the built-in electric field by the combination of both the photothermal electric effect and the gradient of the oxygen-to-carbon composition. These results represent substantial progress toward novel, chemically synthesized graphene-based photosensors and suggest one-step integration of graphene-based optoelectronics in the future. PMID:27634110
Interactive-rate Motion Planning for Concentric Tube Robots.
Torres, Luis G; Baykal, Cenk; Alterovitz, Ron
2014-05-01
Concentric tube robots may enable new, safer minimally invasive surgical procedures by moving along curved paths to reach difficult-to-reach sites in a patient's anatomy. Operating these devices is challenging due to their complex, unintuitive kinematics and the need to avoid sensitive structures in the anatomy. In this paper, we present a motion planning method that computes collision-free motion plans for concentric tube robots at interactive rates. Our method's high speed enables a user to continuously and freely move the robot's tip while the motion planner ensures that the robot's shaft does not collide with any anatomical obstacles. Our approach uses a highly accurate mechanical model of tube interactions, which is important since small movements of the tip position may require large changes in the shape of the device's shaft. Our motion planner achieves its high speed and accuracy by combining offline precomputation of a collision-free roadmap with online position control. We demonstrate our interactive planner in a simulated neurosurgical scenario where a user guides the robot's tip through the environment while the robot automatically avoids collisions with the anatomical obstacles.
Fire feedbacks facilitate invasion of pine savannas by Brazilian pepper (Schinus terebinthifolius).
Stevens, Jens T; Beckage, Brian
2009-10-01
* Fire disturbance can mediate the invasion of ecological communities by nonnative species. Nonnative plants that modify existing fire regimes may initiate a positive feedback that can facilitate their continued invasion. Fire-sensitive plants may successfully invade pyrogenic landscapes if they can inhibit fire in the landscape. * Here, we investigated whether the invasive shrub Brazilian pepper (Schinus terebinthifolius) can initiate a fire-suppression feedback in a fire-dependent pine savanna ecosystem in the southeastern USA. * We found that prescribed burns caused significant (30-45%) mortality of Brazilian pepper at low densities and that savannas with more frequent fires contained less Brazilian pepper. However, high densities of Brazilian pepper reduced fire temperature by up to 200 degrees C, and experienced as much as 80% lower mortality. * A cellular automaton model was used to demonstrate that frequent fire may control low-density populations, but that Brazilian pepper may reach a sufficient density during fire-free periods to initiate a positive feedback that reduces the frequency of fire and converts the savanna to an invasive-dominated forest.
Positive Behavior Support: Sustainability and Continuous Regeneration
ERIC Educational Resources Information Center
McIntosh, Kent; Turri, Mary G.
2014-01-01
Because of its widespread adoption and implementation (in over 13,000 schools in the US; Center on Positive Behavioral Interventions and Supports, 2010), there has been increasing attention to how School-wide Positive Behavior Support (SWPBS) systems can be sustained. Sustained implementation can be defined as "continued use of an…
Local indicators of geocoding accuracy (LIGA): theory and application
Jacquez, Geoffrey M; Rommel, Robert
2009-01-01
Background Although sources of positional error in geographic locations (e.g. geocoding error) used for describing and modeling spatial patterns are widely acknowledged, research on how such error impacts the statistical results has been limited. In this paper we explore techniques for quantifying the perturbability of spatial weights to different specifications of positional error. Results We find that a family of curves describes the relationship between perturbability and positional error, and use these curves to evaluate sensitivity of alternative spatial weight specifications to positional error both globally (when all locations are considered simultaneously) and locally (to identify those locations that would benefit most from increased geocoding accuracy). We evaluate the approach in simulation studies, and demonstrate it using a case-control study of bladder cancer in south-eastern Michigan. Conclusion Three results are significant. First, the shape of the probability distributions of positional error (e.g. circular, elliptical, cross) has little impact on the perturbability of spatial weights, which instead depends on the mean positional error. Second, our methodology allows researchers to evaluate the sensitivity of spatial statistics to positional accuracy for specific geographies. This has substantial practical implications since it makes possible routine sensitivity analysis of spatial statistics to positional error arising in geocoded street addresses, global positioning systems, LIDAR and other geographic data. Third, those locations with high perturbability (most sensitive to positional error) and high leverage (that contribute the most to the spatial weight being considered) will benefit the most from increased positional accuracy. These are rapidly identified using a new visualization tool we call the LIGA scatterplot. Herein lies a paradox for spatial analysis: For a given level of positional error increasing sample density to more accurately follow the underlying population distribution increases perturbability and introduces error into the spatial weights matrix. In some studies positional error may not impact the statistical results, and in others it might invalidate the results. We therefore must understand the relationships between positional accuracy and the perturbability of the spatial weights in order to have confidence in a study's results. PMID:19863795
Hoss, Udo; Jeddi, Iman; Schulz, Mark; Budiman, Erwin; Bhogal, Claire; McGarraugh, Geoffrey
2010-08-01
Commercial continuous subcutaneous glucose monitors require in vivo calibration using capillary blood glucose tests. Feasibility of factory calibration, i.e., sensor batch characterization in vitro with no further need for in vivo calibration, requires a predictable and stable in vivo sensor sensitivity and limited inter- and intra-subject variation of the ratio of interstitial to blood glucose concentration. Twelve volunteers wore two FreeStyle Navigator (Abbott Diabetes Care, Alameda, CA) continuous glucose monitoring systems for 5 days in parallel for two consecutive sensor wears (four sensors per subject, 48 sensors total). Sensors from a prototype sensor lot with a low variability in glucose sensitivity were used for the study. Median sensor sensitivity values based on capillary blood glucose were calculated per sensor and compared for inter- and intra-subject variation. Mean absolute relative difference (MARD) calculation and error grid analysis were performed using a single calibration factor for all sensors to simulate factory calibration and compared to standard fingerstick calibration. Sensor sensitivity variation in vitro was 4.6%, which increased to 8.3% in vivo (P < 0.0001). Analysis of variance revealed no significant inter-subject differences in sensor sensitivity (P = 0.134). Applying a single universal calibration factor retrospectively to all sensors resulted in a MARD of 10.4% and 88.1% of values in Clarke Error Grid Zone A, compared to a MARD of 10.9% and 86% of values in Error Grid Zone A for fingerstick calibration. Factory calibration of sensors for continuous subcutaneous glucose monitoring is feasible with similar accuracy to standard fingerstick calibration. Additional data are required to confirm this result in subjects with diabetes.
Development of a novel lateral flow assay for detection of African swine fever in blood.
Sastre, P; Gallardo, C; Monedero, A; Ruiz, T; Arias, M; Sanz, A; Rueda, P
2016-09-15
African swine fever (ASF) is a viral infectious disease of domestic and wild suids of all breeds and ages, causing a wide range of hemorrhagic syndromes and frequently characterized by high mortality. The disease is endemic in Sub-Saharan Africa and Sardinia. Since 2007, it has also been present in different countries of Eastern Europe, where control measures have not been effective so far. The continued spread poses a serious threat to the swine industry worldwide. In the absence of vaccine, early detection of infected animals is of paramount importance for control of the outbreak, to prevent the transmission of the virus to healthy animals and subsequent spreading of the disease. Current laboratory diagnosis is mainly based on virological methods (antigen and genome detection) and serodiagnosis. In the present work, a Lateral Flow Assay (LFA) for antigen detection has been developed and evaluated. The test is based on the use of a MAb against VP72 protein of ASFV, the major viral capsid protein and highly immunogenic. First experiments using VP72 viral and recombinant protein or inactivated culture virus showed promising results with a sensitivity similar to that of a commercially available Antigen-ELISA. Moreover, these strips were tested with blood from experimentally infected pigs and field animals and the results compared with those of PCR and Antigen-ELISA. For the experimentally infected samples, there was an excellent correlation between the LFA and the ELISA, while the PCR always showed to be more sensitive (38 % positive samples by PCR versus 27 % by LFA). The LFA was demonstrated to be positive for animals with circulating virus levels exceeding 10(4) HAU. With the field samples, once again, the PCR detected more positives than either the Antigen-ELISA or LFA, although here the number of positive samples scored by the LFA exceeded the values obtained with the Antigen-ELISA, showing 60 % positivity vs 48 % for the ELISA. For the two groups of sera, the specificity was close to 100 % indicating that hardly any false positive samples were found. The newly developed LFA allows rapid and reliable detection of ASFV, at field and laboratory level, providing a new useful tool for control programs and in situations where laboratory support and skilled personnel are limited.
Perkins, Daya I.; Trudell, James R.; Asatryan, Liana; Alkana, Ronald L.
2012-01-01
Recent studies highlighted the importance of loop 2 of α1 glycine receptors (GlyRs) in the propagation of ligand-binding energy to the channel gate. Mutations that changed polarity at position 52 in the β hairpin of loop 2 significantly affected sensitivity to ethanol. The present study extends the investigation to charged residues. We found that substituting alanine with the negative glutamate at position 52 (A52E) significantly left-shifted the glycine concentration response curve and increased sensitivity to ethanol, whereas the negative aspartate substitution (A52D) significantly right-shifted the glycine EC50 but did not affect ethanol sensitivity. It is noteworthy that the uncharged glutamine at position 52 (A52Q) caused only a small right shift of the glycine EC50 while increasing ethanol sensitivity as much as A52E. In contrast, the shorter uncharged asparagine (A52N) caused the greatest right shift of glycine EC50 and reduced ethanol sensitivity to half of wild type. Collectively, these findings suggest that charge interactions determined by the specific geometry of the amino acid at position 52 (e.g., the 1-Å chain length difference between aspartate and glutamate) play differential roles in receptor sensitivity to agonist and ethanol. We interpret these results in terms of a new homology model of GlyR based on a prokaryotic ion channel and propose that these mutations form salt bridges to residues across the β hairpin (A52E-R59 and A52N-D57). We hypothesize that these electrostatic interactions distort loop 2, thereby changing agonist activation and ethanol modulation. This knowledge will help to define the key physical-chemical parameters that cause the actions of ethanol in GlyRs. PMID:22357974
Grzybowska, Wanda; Młynarczyk, Grazyna; Młynarczyk, Andrzej; Bocian, Ewa; Luczak, Mirosław; Tyski, Stefan
2007-01-01
The MIC of nine different disinfectants and antiseptics were determined for the Gram-negative and Gram-positive bacteria. Strains originated from clinical specimens, drugs and environment. A sensitivity was determined against chlorhexidinum digluconate (Gram-negative: 0,625-80 mg/L, Gram-positive: 0,3-10 mg/L), benzalconium chloride (Gram-negative: 2,5-1280 mg/L, Gram-positive: 1,25-20 mg/L), salicilic acid (Gram-negative and Gram-positive: 400-1600 mg/L), benzoic acid (Gram-negative: 800-1600 mg/L, Gram-positive: 400-1 600 mg/L), boric acid (Gram-negative: 800-12 800 mg/L, Gram-positive: 1 600-6400 mg/L), chloramine B (Gram-negative: 1600-6400 mg/L, Gram-positive:800- 6400 mg/L), jodine (Gram-negative: 200-1600 mg/L, Gram-positive: 200-1600 mg/L), etacridine lactate (Gram-negative: 40 do > 20480 mg/L, Gram-positive: 40-1280 mg/L) and resorcine (Gram-negative: 1600-6400 mg/L, Gram-positive: 800-6400 mg/L). Diversified values of MIC for different strains were obtained, especially in the case of benzalconium chloride, etacridine lactate, chlorhexidinum digluconate, boric acid and iodine. Strains isolated from environment were usually more susceptible to examined compounds than clinical strains. The biggest diversification of sensitivity was observed among strains originated from drugs where besides sensitive appeared strains characterizing by very high MIC values of some substances, eg. boric acid.
Yin, Yue-Ping; Wei, Wan-Hui; Wang, Hong-Chun; Zhu, Bang-Yong; Yu, Yan-Hua; Chen, Xiang-Sheng; Peeling, Rosanna W; Cohen, Myron S
2009-03-01
China is experiencing a growing syphilis epidemic. Individuals are currently screened and cases are confirmed using traditional serological testing methods. A total of 11 558 serum specimens from patients at 14 sexually transmitted diseases (STD) clinics at provincial, prefecture and county levels in Guangxi Autonomous Region were tested at local clinics using the toluidine red unheated serum test (TRUST) and the SD Bioline Syphilis 3.0 Treponema Pallidum (SD-TP) test and then transported to the National STD Reference Laboratory for TRUST and confirmatory Treponema pallidum particle assay (TPPA) testing. In local clinics, 13.2% of specimens were TRUST positive and 12.8% were TRUST and SD-TP positive. At the Reference Laboratory, 15.4% of specimens were TRUST positive and 11.8% were TRUST and TPPA positive. Local clinics showed a significantly higher prevalence of active syphilis compared with results from the Reference Laboratory (12.8 v. 11.8%, chi(2) = 4.59, P = 0.03). The local TRUST tests had consistent results with Reference Laboratory tests qualitatively among 96.2% of the specimens and quantitatively among 95.5% of the specimens. The algorithm of TRUST screening and then SD-TP confirmation among positive TRUST specimens at local STD clinics had 96.6% sensitivity and 99.3% specificity in diagnosing active syphilis compared with the 'gold standard' based on TRUST and TPPA positivity at the Reference Laboratory (positive predictive value 95.1% and negative predictive value 99.5%). The TRUST screening and SD-TP confirmation in combination can be used at local STD clinics for the efficient diagnosis of serologically active syphilis. However, continuing capacity building and quality assurance remain critical in ensuring the quality of syphilis diagnosis at local clinics.
New design of a passive type RADFET reader for enhanced sensitivity
NASA Astrophysics Data System (ADS)
Lee, Dae-Hee
2016-07-01
We present a new design of a passive type RADFET reader with enhanced radiation sensitivity. Using a electostatic plate, we have applied a static electric field to the gate voltage, which impacts a positive biasing on the p-type MOSFET. The resultant effect shows that 1.8 times of radiation sensitivity increased when we measured the threshold voltage shift of the RADFET exposed to 30 krad irradiation. We discuss further about the characteristic changes of a RADFET according to the positive biasing on the gate voltage.
Batle, Rocio; Vinuesa, Miguel; Bassan, Norberto; Martinez, Adriel; Giacomozzi, Florencia; Chaparro, Soledad; Torres, Valentin; Acebal, Florencia
2012-01-01
Background We previously demonstrated that subcutaneous sensitization with ovalbumin (OVA) induce generation of specific IgE antibodies and quantitative modifications in immune cells populations from different mucosal sites in rabbit. The aim of the study is characterization of eosinophil infiltration in conjunctival mucosa from OVA sensitized and ocular and nasal challenged rabbits. Methods Animals were divided into 4 groups: G1 (n = 9): normal control; G2 (n = 10): subcutaneous sensitized with OVA; G3 (n = 10): subcutaneous sensitized and conjunctival challenged with OVA; G4 (n = 9): subcutaneous sensitized and nasal challenged with OVA. Four hours after challenge animals were sacrificed and obtained samples were processed for histochemistry with cromotrope 2R for eosinophil detection. Cells were counted in 200 high power fields per group. Results Data were expressed as positive cells per high power field. Conjunctival mucosa: G1: 2.3; G2: 3.4; G3: 12.2; G4: 3.3 (G3 vs G1, G2 y G4 P < 0.001). Specific anti-OVA-IgE levels were evaluated by positive passive cutaneous anaphylaxis test (PCA) at 160 fold dilutions. Conclusions We observed an increase in the number of eosinophils-positive cells after local challenge in conjunctiva as compared to normal controls and sensitized and nasal challenged animals. We conclude that systemic sensitization with soluble antigen and conjunctival challenge induces modifications in number of eosinophil populations in conjunctiva but not in nasal challenged rabbits.
Rejection Sensitivity, Jealousy, and the Relationship to Interpersonal Aggression.
Murphy, Anna M; Russell, Gemma
2018-07-01
The development and maintenance of interpersonal relationships lead individuals to risk rejection in the pursuit of acceptance. Some individuals are predisposed to experience a hypersensitivity to rejection that is hypothesized to be related to jealous and aggressive reactions within interpersonal relationships. The current study used convenience sampling to recruit 247 young adults to evaluate the relationship between rejection sensitivity, jealousy, and aggression. A mediation model was used to test three hypotheses: Higher scores of rejection sensitivity would be positively correlated to higher scores of aggression (Hypothesis 1); higher scores of rejection sensitivity would be positively correlated to higher scores of jealousy (Hypothesis 2); jealousy would mediate the relationship between rejection sensitivity and aggression (Hypothesis 3). Study results suggest a tendency for individuals with high rejection sensitivity to experience higher levels of jealousy, and subsequently have a greater propensity for aggression, than individuals with low rejection sensitivity. Future research that substantiates a link between hypersensitivity to rejection, jealousy, and aggression may provide an avenue for prevention, education, or intervention in reducing aggression within interpersonal relationships.
Farrow, Claire; Blissett, Jackie
2014-01-01
Maternal mind-mindedness, or the tendency to view the child as a mental agent, has been shown to predict sensitive and responsive parenting behavior. As yet the role of mind-mindedness has not been explored in the context of feeding interactions. This study evaluates the relations between maternal mind-mindedness at 6 months of infant age and subsequently observed maternal sensitivity and feeding behaviors with children at age 1 year. Maternal mind-mindedness was greater in mothers who had breast-fed compared to formula-fed. Controlling for breast-feeding, mind-mindedness at 6 months was correlated with observations of more sensitive and positive feeding behaviors at 1 year of age. Mind-mindedness was also associated with greater general maternal sensitivity in play and this general parenting sensitivity mediated the effect of mind-mindedness on more sensitive and positive feeding behaviors. Interventions to promote maternal tendency to consider their child's mental states may encourage more adaptive parental feeding behaviors.
The Clinical Impact of Bet v 6 in Birch Pollen-Sensitized Patients.
Gellrich, Donata; Eder, Katharina; San Nicoló, Marion; Berghaus, Alexander; Gröger, Moritz
2017-01-01
Bet v 6, a minor birch pollen allergen, is commercially available for allergen-specific IgE antibody testing. However, there is hardly any literature on the clinical impact of Bet v 6. The aim of the present study was to analyze if testing specific IgE against Bet v 6 can add valuable benefit to the standard diagnostics of birch pollen-sensitized patients, especially in patients with unknown sensitization-eliciting allergens. Birch pollen-sensitized patients with missing IgE reactivity against Bet v 1, 2, and 4 were tested for specific IgE antibodies against Bet v 6. For comparison, an equal number of randomly selected patients with birch pollen sensitization, regardless of their individual sensitization patterns, were tested for specific anti-Bet v 6. Of 57 cases with missing reactivity against the standard birch pollen allergens, 2 patients were positive for Bet v 6. In the representative sample, 3 patients showed specific IgE against Bet v 6 - resulting in a total prevalence of 5%. None of the Bet v 6-positive patients showed allergic symptoms after exposure to birch pollen or an oral allergy syndrome. An increased prevalence of asthma and a higher degree of sensitization were the only distinctive clinical features in Bet v 6-positive patients. Among birch pollen-sensitized patients, the prevalence of specific IgE against Bet v 6 is low. Further, sensitization to Bet v 6, which shows characteristics of a panallergen, remains clinically silent. Therefore, determination of anti-Bet v 6 is not considered useful in the clinical routine. © 2017 S. Karger AG, Basel.
Moesker, F M; van Kampen, J J A; Aron, G; Schutten, M; van de Vijver, D A M C; Koopmans, M P G; Osterhaus, A D M E; Fraaij, P L A
2016-06-01
Rapid antigen detection tests (RADTs) are increasingly used to detect influenza viruses and respiratory syncytial virus (RSV). However, their sensitivity and specificity are a matter of debate, challenging their clinical usefulness. Comparing diagnostic performances of BinaxNow Influenza AB(®) (BNI) and BinaxNow RSV(®) (BNR), to those of real-time reverse transcriptase PCR (RT-PCR), virus isolation and direct immunofluorescence (D-IF) in paediatric patients. Between November 2005 and September 2013, 521 nasal washings from symptomatic children (age <5 years) attending our tertiary care centre were tested, with a combination of the respective assays using RT-PCR as gold standard. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of BNI were 69% (confidence interval [CI] [51-83]), 96% [94-97], 55% [39-70] and 98% [96-99] respectively. Of eleven false-negative samples, RT-PCR Ct-values were higher than all RT-PCR positive test results (27 vs 22, p=0.012). Of twenty false-positive samples, none were culture positive and two tested positive in D-IF. Sensitivity, specificity, PPV and NPV for BNR were 79% [73-85], 98% [96-99], 97% [93-99] and 88% [84-91]. Of the 42 false-negative samples the median Ct-value was higher than that of all RT-PCR positive samples (31 vs 23, p<0.0001). Five false-positive samples were detected. Three of these tested positive for RSV in virus isolation and D-IF. RADTs have a high specificity with BNR being superior to BNI. However, their relative low sensitivity limits their usefulness for clinical decision making in a tertiary care paediatric hospital. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Development of a one-dimensional Position Sensitive Detector for tracking applications
NASA Astrophysics Data System (ADS)
Lydecker, Leigh Kent, IV
Optical Position Sensitive Detectors (PSDs) are a non-contact method of tracking the location of a light spot. Silicon-based versions of such sensors are fabricated with standard CMOS processing, are inexpensive and provide a real-time, analog signal output corresponding to the position of the light spot. Because they are non-contact, they do not degrade over time from surface friction due to repetitive sliding motion associated with standard full contact sliding potentiometers. This results in long, reliable device lifetimes. In this work, an innovative PSD was developed to replace the linear hard contact potentiometer currently being used in a human-computer interface architecture. First, a basic lateral effect PSD was developed to provide real-time positioning of the mouthpiece used in the interface architecture which tracks along a single axis. During the course of this work, multiple device geometries were fabricated and analyzed resulting in a down selection of a final design. This final device design was then characterized in terms of resolution and responsivity and produced in larger quantities as initial prototypes for the test product integration. Finally, an electronic readout circuit was developed in order to interface the dual- line lateral effect PSD developed in this thesis with specifications required for product integration. To simplify position sensing, an innovative type of optical position sensor was developed using a linear photodiodes with back-to-back connections. This so- called Self-Balancing Position Sensitive Detector (SBPSD) requires significantly fewer processing steps than the basic lateral effect position sensitive detector discussed above and eliminates the need for external readout circuitry entirely. Prototype devices were fabricated in this work, and the performance characteristics of these devices were established paving the way for ultimate integration into the target product as well as additional applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hale, William M.; Stoner, Richard D.
1958-05-01
Continuous exposure to gamma -radiation at a dose rate of 4 rep/hr enhanced the severity of anaphylactnic shock ln mice sensitized with tetanus toxoid and challenged 1 hour or 7 days postradiation with fluid tetanus toxoid. A sharp increase in susceptibility to fatal anaphylaxis was observed as the accumulated dose was increased from 192 to 288 rep. Recovery from the enhancing effect of continuous gamma -radiation began during the second week postradiation; complete recovery occurred during the third week after an accumulated dose of 672 rep. Anaphylactic shock was demonstrable in mice sensitized 6 months before challenge with the specificmore » antigen. An enhanced susceptibility to fatal anaphylaxis was obtained when these animals were given an accumulated dose of 288 rep and challenged 1 hour postradiation. Passive anaphylaxis was more severe in irradiated mice sensitized with homopogous antitoxin 1 hour postradiation and challenged the following day with tetanus toxoid. The antihistaminic agent Thephorin afforded complete protection from fatal anaphypaxis in irradiated mice. (auth)« less