Sample records for continuous wave cardiac

  1. Noninvasive estimation of cardiac systolic function using continuous-wave Doppler echocardiography in dogs with experimental mitral regurgitation.

    PubMed

    Asano, K; Masui, Y; Masuda, K; Fujinaga, T

    2002-01-01

    To evaluate the feasibility of noninvasive estimation of cardiac systolic function using transthoracic continuous-wave Doppler echocardiography in dogs with mitral regurgitation. Seven mongrel dogs with experimental mitral regurgitation were used. Left ventriculography and measurement of pulmonary capillary wedge pressure were performed under inhalational anaesthesia. A micromanometer-tipped catheter was placed into the left ventricle and transthoracic echocardiography was carried out. The peak rate of left ventricular pressure rise (peak dP/dt) was derived simultaneously by continuous-wave Doppler and manometer measurements. The Doppler-derived dP/dt was compared with the catheter-measured peak dP/dt in the dogs. Classification of the severity of mitral regurgitation in the dogs was as follows: 1+, 2 dogs; 2+, 1 dog; 3+, 2 dogs; 4+, 1 dog; and not examined, 1 dog. We were able to derive dP/dt from the transthoracic continuous-wave Doppler echocardiography in all dogs. Doppler-derived dP/dt had a significant correlation with the catheter-measured peak dP/dt (r = 0.90, P < 0.0001). It was demonstrated that transthoracic continuous-wave Doppler echocardiography is a feasible method of noninvasive estimation of cardiac systolic function in dogs with experimental mitral regurgitation and may have clinical usefulness in canine patients with spontaneous mitral regurgitation.

  2. Electromagnetic induction and radiation-induced abnormality of wave propagation in excitable media

    NASA Astrophysics Data System (ADS)

    Ma, Jun; Wu, Fuqiang; Hayat, Tasawar; Zhou, Ping; Tang, Jun

    2017-11-01

    Continuous wave emitting from sinus node of the heart plays an important role in wave propagating among cardiac tissue, while the heart beating can be terminated when the target wave is broken into turbulent states by electromagnetic radiation. In this investigation, local periodical forcing is applied on the media to induce continuous target wave in the improved cardiac model, which the effect of electromagnetic induction is considered by using magnetic flux, then external electromagnetic radiation is imposed on the media. It is found that target wave propagation can be blocked to stand in a local area and the excitability of media is suppressed to approach quiescent but homogeneous state when electromagnetic radiation is imposed on the media. The sampled time series for membrane potentials decrease to quiescent state due to the electromagnetic radiation. It could accounts for the mechanism of abnormality in heart failure exposed to continuous electromagnetic field.

  3. Characterization of Electrocardiogram Changes Throughout a Marathon

    PubMed Central

    Callaway, Clifton; Salcido, David; McEntire, Serina; Roth, Ronald; Hostler, David

    2014-01-01

    Purpose There are few data examining cardiovascular physiology throughout a marathon. This study was devised to characterize electrocardiographic activity continuously throughout a marathon. Methods Cardiac activity was recorded from 19 subjects wearing a Holter monitor during a marathon. The 19 subjects (14 men and 5 women) were aged 39 ± 16 years (mean ± SD) and completed a marathon in 4:32:16 ± 1:23:35. Heart rate (HR), heart rate variability (HRV), T-wave amplitude, T-wave amplitude variability, and T-wave alternans (TWA) were evaluated continuously throughout the marathon. Results Averaged across all subjects, HRV, T-wave amplitude variability, and TWA increased throughout the marathon. Increased variability in T-wave amplitude occurred in 86% of subjects, characterized by complex oscillatory patterns and TWA. Three minutes after the marathon, HR was elevated and HRV was suppressed relative to the pre-marathon state. Conclusion HRV and T-wave amplitude variability, especially in the form of TWA, increase throughout a marathon. Increasing TWA as a marathon progresses likely represents a physiologic process as no arrhythmias or cardiac events were observed. PMID:24832192

  4. Heat, heat waves, and out-of-hospital cardiac arrest.

    PubMed

    Kang, Si-Hyuck; Oh, Il-Young; Heo, Jongbae; Lee, Hyewon; Kim, Jungeun; Lim, Woo-Hyun; Cho, Youngjin; Choi, Eue-Keun; Yi, Seung-Muk; Sang, Do Shin; Kim, Ho; Youn, Tae-Jin; Chae, In-Ho; Oh, Seil

    2016-10-15

    Cardiac arrest is one of the common presentations of cardiovascular disorders and a leading cause of death. There are limited data on the relationship between out-of-hospital cardiac arrest (OHCA) and ambient temperatures, specifically extreme heat. This study investigated how heat and heat waves affect the occurrence of OHCA. Seven major cities in Korea with more than 1 million residents were included in this study. A heat wave was defined as a daily mean temperature above the 98th percentile of the yearly distribution for at least two consecutive days. A total of 50,318 OHCAs of presumed cardiac origin were identified from the nationwide emergency medical service database between 2006 and 2013. Ambient temperature and OHCA had a J-shaped relationship with a trough at 28°C. Heat waves were shown to be associated with a 14-% increase in the risk of OHCA. Adverse effects were apparent from the beginning of each heat wave period and slightly increased during its continuation. Excess OHCA events during heat waves occurred between 3PM and 5PM. Subgroup analysis showed that those 65years or older were significantly more susceptible to heat waves. Ambient temperature and OHCA had a J-shaped relationship. The risk of OHCA was significantly increased with heat waves. Excess OHCA events primarily occurred during the afternoon when the temperature was high. We found that the elderly were more susceptible to the deleterious effects of heat waves. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Medical applications of shortwave FM radar: remote monitoring of cardiac and respiratory motion.

    PubMed

    Mostov, K; Liptsen, E; Boutchko, R

    2010-03-01

    This article introduces the use of low power continuous wave frequency modulated radar for medical applications, specifically for remote monitoring of vital signs in patients. Gigahertz frequency radar measures the electromagnetic wave signal reflected from the surface of a human body and from tissue boundaries. Time series analysis of the measured signal provides simultaneous information on range, size, and reflective properties of multiple targets in the field of view of the radar. This information is used to extract the respiratory and cardiac rates of the patient in real time. The results from several preliminary human subject experiments are provided. The heart and respiration rate frequencies extracted from the radar signal match those measured independently for all the experiments, including a case when additional targets are simultaneously resolved in the field of view and a case when only the patient's extremity is visible to the radar antennas. Micropower continuous wave FM radar is a reliable, robust, inexpensive, and harmless tool for real-time monitoring of the cardiac and respiratory rates. Additionally, it opens a range of new and exciting opportunities in diagnostic and critical care medicine. Differences between the presented approach and other types of radars used for biomedical applications are discussed.

  6. Dynamical mechanism of atrial fibrillation: A topological approach

    NASA Astrophysics Data System (ADS)

    Marcotte, Christopher D.; Grigoriev, Roman O.

    2017-09-01

    While spiral wave breakup has been implicated in the emergence of atrial fibrillation, its role in maintaining this complex type of cardiac arrhythmia is less clear. We used the Karma model of cardiac excitation to investigate the dynamical mechanisms that sustain atrial fibrillation once it has been established. The results of our numerical study show that spatiotemporally chaotic dynamics in this regime can be described as a dynamical equilibrium between topologically distinct types of transitions that increase or decrease the number of wavelets, in general agreement with the multiple wavelets' hypothesis. Surprisingly, we found that the process of continuous excitation waves breaking up into discontinuous pieces plays no role whatsoever in maintaining spatiotemporal complexity. Instead, this complexity is maintained as a dynamical balance between wave coalescence—a unique, previously unidentified, topological process that increases the number of wavelets—and wave collapse—a different topological process that decreases their number.

  7. J Waves for Predicting Cardiac Events in Hypertrophic Cardiomyopathy.

    PubMed

    Tsuda, Toyonobu; Hayashi, Kenshi; Konno, Tetsuo; Sakata, Kenji; Fujita, Takashi; Hodatsu, Akihiko; Nagata, Yoji; Teramoto, Ryota; Nomura, Akihiro; Tanaka, Yoshihiro; Furusho, Hiroshi; Takamura, Masayuki; Kawashiri, Masa-Aki; Fujino, Noboru; Yamagishi, Masakazu

    2017-10-01

    This study sought to investigate whether the presence of J waves was associated with cardiac events in patients with hypertrophic cardiomyopathy (HCM). It has been uncertain whether the presence of J waves predicts life-threatening cardiac events in patients with HCM. This study evaluated consecutive 338 patients with HCM (207 men; age 61 ± 17 years of age). A J-wave was defined as J-point elevation >0.1 mV in at least 2 contiguous inferior and/or lateral leads. Cardiac events were defined as sudden cardiac death, ventricular fibrillation or sustained ventricular tachycardia, or appropriate implantable cardiac defibrillator therapy. The study also investigated whether adding the J-wave in a conventional risk model improved a prediction of cardiac events. J waves were seen in 46 (13.6%) patients at registration. Cardiac events occurred in 31 patients (9.2%) during median follow-up of 4.9 years (interquartile range: 2.6 to 7.1 years). In a Cox proportional hazards model, the presence of J waves was significantly associated with cardiac events (adjusted hazard ratio: 4.01; 95% confidence interval [CI]: 1.78 to 9.05; p = 0.001). Compared with the conventional risk model, the model using J waves in addition to conventional risks better predicted cardiac events (net reclassification improvement, 0.55; 95% CI: 0.20 to 0.90; p = 0.002). The presence of J waves was significantly associated with cardiac events in HCM. Adding J waves to conventional cardiac risk factors improved prediction of cardiac events. Further confirmatory studies are needed before considering J-point elevation as a marker of risk for use in making management decisions regarding risk in patients with HCM. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  8. Removal of pinned scroll waves in cardiac tissues by electric fields in a generic model of three-dimensional excitable media.

    PubMed

    Pan, De-Bei; Gao, Xiang; Feng, Xia; Pan, Jun-Ting; Zhang, Hong

    2016-02-24

    Spirals or scroll waves pinned to heterogeneities in cardiac tissues may cause lethal arrhythmias. To unpin these life-threatening spiral waves, methods of wave emission from heterogeneities (WEH) induced by low-voltage pulsed DC electric fields (PDCEFs) and circularly polarized electric fields (CPEFs) have been used in two-dimensional (2D) cardiac tissues. Nevertheless, the unpinning of scroll waves in three-dimensional (3D) cardiac systems is much more difficult than that of spiral waves in 2D cardiac systems, and there are few reports on the removal of pinned scroll waves in 3D cardiac tissues by electric fields. In this article, we investigate in detail the removal of pinned scroll waves in a generic model of 3D excitable media using PDCEF, AC electric field (ACEF) and CPEF, respectively. We find that spherical waves can be induced from the heterogeneities by these electric fields in initially quiescent excitable media. However, only CPEF can induce spherical waves with frequencies higher than that of the pinned scroll wave. Such higher-frequency spherical waves induced by CPEF can be used to drive the pinned scroll wave out of the cardiac systems. We hope this remarkable ability of CPEF can provide a better alternative to terminate arrhythmias caused by pinned scroll waves.

  9. Monitoring cardiac motion in CT using a continuous wave radar embedded in the patient table.

    PubMed

    Pfanner, Florian; Allmendinger, Thomas; Bohn, Birgit; Flohr, Thomas; Kachelrieß, Marc

    2014-08-01

    To avoid motion artifacts, medical imaging devices are often synchronized with the patient's cardiac motion. Today, the ECG is used to determine the heartbeat and therewith trigger the imaging device. However, the ECG requires additional effort to prepare the patient, e.g., mount and wire electrodes and it is not able to determine the motion of the heart. An interesting alternative to assess the cardiac motion is continuous wave radar. The aim of this work is to evaluate such a radar system focusing on measuring the cardiac motion. A radar system operating in the 860 MHz band is used. In the intended application of the radar system, the antennas are located close to the patient's body, for example, inside the table of a CT system. The radar waves propagate into the patient's body and are reflected at tissue boundaries, for example, at the borderline between muscle and adipose tissue, or at the boundaries of organs. Here, the authors focus on the detection of cardiac motion. The radar system consists of hardware as well as of dedicated signal processing software to extract the desired information from the radar signals. The radar system hardware and the signal processing algorithms were tested with data from ten volunteers. As a reference, the ECG was recorded simultaneously with the radar measurements. Additionally, ultrasound measurements are performed and compared with the motion information from the radar data. According to the authors' measurements on volunteers (test persons), the heartbeat and heart rate can be detected well using the proposed radar system. The authors were further able to extract the amplitude and phase of the heart motion itself from the radar data. This was confirmed by the ultrasound measurements. However, this motion assessment is dependent on the antenna position and it remains unclear which antenna sees the motion that is the most relevant to CT imaging. A continuous wave radar operating in the near field of the antennas can be used to determine the heartbeat and the cardiac motion of humans without special patient preparation. The authors' radar system is very close to the patient because it is embedded in the patient table, but it has no direct contact to the patient or to the patient skin (as it would be necessary to acquire the ECG of the patient). Therefore, radar motion monitoring does not require special patient preparation. In contrast to other methods used today, this is a significant improvement. The authors' radar system may allow to trigger a CT scan in dependency of the cardiac phase, without requiring an ECG, and it allows to determine quiet, and thus favorable, heart phases prior to the scan start.

  10. Removal of pinned scroll waves in cardiac tissues by electric fields in a generic model of three-dimensional excitable media

    PubMed Central

    Pan, De-Bei; Gao, Xiang; Feng, Xia; Pan, Jun-Ting; Zhang, Hong

    2016-01-01

    Spirals or scroll waves pinned to heterogeneities in cardiac tissues may cause lethal arrhythmias. To unpin these life-threatening spiral waves, methods of wave emission from heterogeneities (WEH) induced by low-voltage pulsed DC electric fields (PDCEFs) and circularly polarized electric fields (CPEFs) have been used in two-dimensional (2D) cardiac tissues. Nevertheless, the unpinning of scroll waves in three-dimensional (3D) cardiac systems is much more difficult than that of spiral waves in 2D cardiac systems, and there are few reports on the removal of pinned scroll waves in 3D cardiac tissues by electric fields. In this article, we investigate in detail the removal of pinned scroll waves in a generic model of 3D excitable media using PDCEF, AC electric field (ACEF) and CPEF, respectively. We find that spherical waves can be induced from the heterogeneities by these electric fields in initially quiescent excitable media. However, only CPEF can induce spherical waves with frequencies higher than that of the pinned scroll wave. Such higher-frequency spherical waves induced by CPEF can be used to drive the pinned scroll wave out of the cardiac systems. We hope this remarkable ability of CPEF can provide a better alternative to terminate arrhythmias caused by pinned scroll waves. PMID:26905367

  11. ALGORITHM OF CARDIO COMPLEX DETECTION AND SORTING FOR PROCESSING THE DATA OF CONTINUOUS CARDIO SIGNAL MONITORING.

    PubMed

    Krasichkov, A S; Grigoriev, E B; Nifontov, E M; Shapovalov, V V

    The paper presents an algorithm of cardio complex classification as part of processing the data of continuous cardiac monitoring. R-wave detection concurrently with cardio complex sorting is discussed. The core of this approach is the use of prior information about. cardio complex forms, segmental structure, and degree of kindness. Results of the sorting algorithm testing are provided.

  12. Control of spiral waves and turbulent states in a cardiac model by travelling-wave perturbations

    NASA Astrophysics Data System (ADS)

    Wang, Peng-Ye; Xie, Ping; Yin, Hua-Wei

    2003-06-01

    We propose a travelling-wave perturbation method to control the spatiotemporal dynamics in a cardiac model. It is numerically demonstrated that the method can successfully suppress the wave instability (alternans in action potential duration) in the one-dimensional case and convert spiral waves and turbulent states to the normal travelling wave states in the two-dimensional case. An experimental scheme is suggested which may provide a new design for a cardiac defibrillator.

  13. Controlling spiral waves and turbulent states in cardiac tissue by traveling wave perturbations

    NASA Astrophysics Data System (ADS)

    Wang, Peng-Ye; Xie, Ping

    2000-03-01

    We propose a traveling wave perturbation method to control the spatiotemporal dynamics in cardiac tissue. With a two-variable model we demonstrate that the method can successfully suppress the wave instability (alternans in action potential duration) in the one-dimensional case and convert spiral waves and turbulent states to the normal traveling wave state in the two-dimensional case. An experimental scheme is suggested which may provide a new design for a cardiac defibrillator.

  14. Extracardiac conduit obstruction: initial experience in the use of Doppler echocardiography for noninvasive estimation of pressure gradient.

    PubMed

    Reeder, G S; Currie, P J; Fyfe, D A; Hagler, D J; Seward, J B; Tajik, A J

    1984-11-01

    Extracardiac valved conduits are often employed in the repair of certain complex congenital heart defects; late obstruction is a well recognized problem that usually requires catheterization for definitive diagnosis. A reliable noninvasive method for detecting conduit stenosis would be clinically useful in identifying the small proportion of patients who develop this problem. Continuous wave Doppler echocardiography has been used successfully to estimate cardiac valvular obstructive lesions noninvasively. Twenty-three patients with prior extracardiac conduit placement for complex congenital heart disease underwent echocardiographic and continuous wave Doppler echocardiographic examinations to determine the presence and severity of conduit stenosis. In 20 of the 23 patients, an adequate conduit flow velocity profile was obtained, and in 10 an abnormally increased conduit flow velocity was present. All but one patient had significant obstruction proven at surgery and in one patient, surgery was planned. In three patients, an adequate conduit flow velocity profile could not be obtained but obstruction was still suspected based on high velocity tricuspid regurgitant Doppler signals. In these three patients, subsequent surgery also proved that conduit stenosis was present. Doppler-predicted gradients and right ventricular pressures showed an overall good correlation (r = 0.90) with measurements at subsequent cardiac catheterization. Continuous wave Doppler echocardiography appears to be a useful noninvasive tool for the detection and semiquantitation of extracardiac conduit stenosis.

  15. Ultrafast Ultrasound Imaging of Ocular Anatomy and Blood Flow

    PubMed Central

    Urs, Raksha; Ketterling, Jeffrey A.; Silverman, Ronald H.

    2016-01-01

    Purpose Ophthalmic ultrasound imaging is currently performed with mechanically scanned single-element probes. These probes have limited capabilities overall and lack the ability to image blood flow. Linear-array systems are able to detect blood flow, but these systems exceed ophthalmic acoustic intensity safety guidelines. Our aim was to implement and evaluate a new linear-array–based technology, compound coherent plane-wave ultrasound, which offers ultrafast imaging and depiction of blood flow at safe acoustic intensity levels. Methods We compared acoustic intensity generated by a 128-element, 18-MHz linear array operated in conventionally focused and plane-wave modes and characterized signal-to-noise ratio (SNR) and lateral resolution. We developed plane-wave B-mode, real-time color-flow, and high-resolution depiction of slow flow in postprocessed data collected continuously at a rate of 20,000 frames/s. We acquired in vivo images of the posterior pole of the eye by compounding plane-wave images acquired over ±10° and produced images depicting orbital and choroidal blood flow. Results With the array operated conventionally, Doppler modes exceeded Food and Drug Administration safety guidelines, but plane-wave modalities were well within guidelines. Plane-wave data allowed generation of high-quality compound B-mode images, with SNR increasing with the number of compounded frames. Real-time color-flow Doppler readily visualized orbital blood flow. Postprocessing of continuously acquired data blocks of 1.6-second duration allowed high-resolution depiction of orbital and choroidal flow over the cardiac cycle. Conclusions Newly developed high-frequency linear arrays in combination with plane-wave techniques present opportunities for the evaluation of ocular anatomy and blood flow, as well as visualization and analysis of other transient phenomena such as vessel wall motion over the cardiac cycle and saccade-induced vitreous motion. PMID:27428169

  16. The dynamics of spiral tip adjacent to inhomogeneity in cardiac tissue

    NASA Astrophysics Data System (ADS)

    Zhang, Juan; Tang, Jun; Ma, Jun; Luo, Jin Ming; Yang, Xian Qing

    2018-02-01

    Rotating spiral waves in cardiac tissue are implicated in life threatening cardiac arrhythmias. Experimental and theoretical evidences suggest the inhomogeneities in cardiac tissue play a significant role in the dynamics of spiral waves. Based on a modified 2D cardiac tissue model, the interaction of inhomogeneity on the nearby rigidly rotating spiral wave is numerically studied. The adjacent area of the inhomogeneity is divided to two areas, when the initial rotating center of the spiral tip is located in the two areas, the spiral tip will be attracted and anchor on the inhomogeneity finally, or be repulsed away. The width of the area is significantly dependent on the intensity and size of the inhomogeneity. Our numerical study sheds some light on the mechanism of the interaction of inhomogeneity on the spiral wave in cardiac tissue.

  17. Initiation and dynamics of a spiral wave around an ionic heterogeneity in a model for human cardiac tissue.

    PubMed

    Defauw, Arne; Dawyndt, Peter; Panfilov, Alexander V

    2013-12-01

    In relation to cardiac arrhythmias, heterogeneity of cardiac tissue is one of the most important factors underlying the onset of spiral waves and determining their type. In this paper, we numerically model heterogeneity of realistic size and value and study formation and dynamics of spiral waves around such heterogeneity. We find that the only sustained pattern obtained is a single spiral wave anchored around the heterogeneity. Dynamics of an anchored spiral wave depend on the extent of heterogeneity, and for certain heterogeneity size, we find abrupt regional increase in the period of excitation occurring as a bifurcation. We study factors determining spatial distribution of excitation periods of anchored spiral waves and discuss consequences of such dynamics for cardiac arrhythmias and possibilities for experimental testings of our predictions.

  18. Scroll wave dynamics in a three-dimensional cardiac tissue model: roles of restitution, thickness, and fiber rotation.

    PubMed Central

    Qu, Z; Kil, J; Xie, F; Garfinkel, A; Weiss, J N

    2000-01-01

    Scroll wave (vortex) breakup is hypothesized to underlie ventricular fibrillation, the leading cause of sudden cardiac death. We simulated scroll wave behaviors in a three-dimensional cardiac tissue model, using phase I of the Luo-Rudy (LR1) action potential model. The effects of action potential duration (APD) restitution, tissue thickness, filament twist, and fiber rotation were studied. We found that APD restitution is the major determinant of scroll wave behavior and that instabilities arising from APD restitution are the main determinants of scroll wave breakup in this cardiac model. We did not see a "thickness-induced instability" in the LR1 model, but a minimum thickness is required for scroll breakup in the presence of fiber rotation. The major effect of fiber rotation is to maintain twist in a scroll wave, promoting filament bending and thus scroll breakup. In addition, fiber rotation induces curvature in the scroll wave, which weakens conduction and further facilitates wave break. PMID:10827961

  19. ``Smart'' baroreception along the aortic arch, with reference to essential hypertension

    NASA Astrophysics Data System (ADS)

    Kember, G. C.; Zamir, M.; Armour, J. A.

    2004-11-01

    Beat-to-beat regulation of heart rate is dependent upon sensing of local stretching or local “disortion” by aortic baroreceptors. Distortions of the aortic wall are due mainly to left ventricular output and to reflected waves arising from the arterial tree. Distortions are generally believed to be useful in cardiac control since stretch receptors or aortic baroreceptors embedded in the adventitia of the aortic wall, transduce the distortions to cardiovascular neural reflex pathways responsible for beat-to-beat regulation of heart rate. Aortic neuroanatomy studies have also found a continuous strip of mechanosensory neurites spread along the aortic inner arch. Although their purpose is now unknown, such a combined sensing capacity would allow measurement of the space and time dependence of inner arch wall distortions due, among other things, to traveling waves associated with pulsatile flow in an elastic tube. We call this sensing capability-“smart baroreception.” In this paper we use an arterial tree model to show that the cumulative effects of wave reflections, from many sites far downstream, have a surprisingly pronounced effect on the pressure distribution in the root segment of the tree. By this mechanism global hemodynamics can be focused by wave reflections back to the aortic arch, where they can rapidly impact cardiac control via smart baroreception. Such sensing is likely important to maintain efficient heart function. However, alterations in the arterial tree due to aging and other natural processes can lead in such a system to altered cardiac control and essential hypertension.

  20. Eliminating spiral waves pinned to an anatomical obstacle in cardiac myocytes by high-frequency stimuli.

    PubMed

    Isomura, Akihiro; Hörning, Marcel; Agladze, Konstantin; Yoshikawa, Kenichi

    2008-12-01

    The unpinning of spiral waves by the application of high-frequency wave trains was studied in cultured cardiac myocytes. Successful unpinning was observed when the frequency of the paced waves exceeded a critical level. The unpinning process was analyzed by a numerical simulation with a model of cardiac tissue. The mechanism of unpinning by high-frequency stimuli is discussed in terms of local entrainment failure, through a reduction of the two-dimensional spatial characteristics into one dimension.

  1. The Interplay of Rogue and Clustered Ryanodine Receptors Regulates Ca2+ Waves in Cardiac Myocytes.

    PubMed

    Chen, Xudong; Feng, Yundi; Huo, Yunlong; Tan, Wenchang

    2018-01-01

    Ca 2+ waves in cardiac myocytes can lead to arrhythmias owing to delayed after-depolarisations. Based on Ca 2+ regulation from the junctional sarcoplasmic reticulum (JSR), a mathematical model was developed to investigate the interplay of clustered and rogue RyRs on Ca 2+ waves. The model successfully reproduces Ca 2+ waves in cardiac myocytes, which are in agreement with experimental results. A new wave propagation mode of "spark-diffusion-quark-spark" is put forward. It is found that rogue RyRs greatly increase the initiation of Ca 2+ sparks, further contribute to the formation and propagation of Ca 2+ waves when the free Ca 2+ concentration in JSR lumen ([Ca 2+ ] lumen ) is higher than a threshold value of 0.7 mM. Computational results show an exponential increase in the velocity of Ca 2+ waves with [Ca 2+ ] lumen . In addition, more CRUs of rogue RyRs and Ca 2+ release from rogue RyRs result in higher velocity and amplitude of Ca 2+ waves. Distance between CRUs significantly affects the velocity of Ca 2+ waves, but not the amplitude. This work could improve understanding the mechanism of Ca 2+ waves in cardiac myocytes.

  2. The Interplay of Rogue and Clustered Ryanodine Receptors Regulates Ca2+ Waves in Cardiac Myocytes

    PubMed Central

    Chen, Xudong; Feng, Yundi; Huo, Yunlong; Tan, Wenchang

    2018-01-01

    Ca2+ waves in cardiac myocytes can lead to arrhythmias owing to delayed after-depolarisations. Based on Ca2+ regulation from the junctional sarcoplasmic reticulum (JSR), a mathematical model was developed to investigate the interplay of clustered and rogue RyRs on Ca2+ waves. The model successfully reproduces Ca2+ waves in cardiac myocytes, which are in agreement with experimental results. A new wave propagation mode of “spark-diffusion-quark-spark” is put forward. It is found that rogue RyRs greatly increase the initiation of Ca2+ sparks, further contribute to the formation and propagation of Ca2+ waves when the free Ca2+ concentration in JSR lumen ([Ca2+]lumen) is higher than a threshold value of 0.7 mM. Computational results show an exponential increase in the velocity of Ca2+ waves with [Ca2+]lumen. In addition, more CRUs of rogue RyRs and Ca2+ release from rogue RyRs result in higher velocity and amplitude of Ca2+ waves. Distance between CRUs significantly affects the velocity of Ca2+ waves, but not the amplitude. This work could improve understanding the mechanism of Ca2+ waves in cardiac myocytes. PMID:29755362

  3. Cardiac output in idiopathic normal pressure hydrocephalus: association with arterial blood pressure and intracranial pressure wave amplitudes and outcome of shunt surgery

    PubMed Central

    2011-01-01

    Background In patients with idiopathic normal pressure hydrocephalus (iNPH) responding to shunt surgery, we have consistently found elevated intracranial pressure (ICP) wave amplitudes during diagnostic ICP monitoring prior to surgery. It remains unknown why ICP wave amplitudes are increased in these patients. Since iNPH is accompanied by a high incidence of vascular co-morbidity, a possible explanation is that there is reduced vascular compliance accompanied by elevated arterial blood pressure (ABP) wave amplitudes and even altered cardiac output (CO). To investigate this possibility, the present study was undertaken to continuously monitor CO to determine if it is correlated to ABP and ICP wave amplitudes and the outcome of shunting in iNPH patients. It was specifically addressed whether the increased ICP wave amplitudes seen in iNPH shunt responders were accompanied by elevated CO and/or ABP wave amplitude levels. Methods Prospective iNPH patients (29) were clinically graded using an NPH grading scale. Continuous overnight minimally-invasive monitoring of CO and ABP was done simultaneously with ICP monitoring; the CO, ABP, and ICP parameters were parsed into 6-second time windows. Patients were assessed for shunt surgery on clinical grade, Evan's index, and ICP wave amplitude. Follow-up clinical grading was performed 12 months after surgery. Results ICP wave amplitudes but not CO or ABP wave amplitude, showed good correlation with the response to shunt treatment. The patients with high ICP wave amplitude did not have accompanying high levels of CO or ABP wave amplitude. Correlation analysis between CO and ICP wave amplitudes in individual patients showed different profiles [significantly positive in 10 (35%) and significantly negative in 16 (55%) of 29 recordings]. This depended on whether there was also a correlation between ABP and ICP wave amplitudes and on the average level of ICP wave amplitude. Conclusions These results gave no evidence that the increased levels of ICP wave amplitudes seen in iNPH shunt responders prior to surgery were accompanied by elevated levels of ABP wave amplitudes or elevated CO. In the individual patients the correlation between CO and ICP wave amplitude was partly related to an association between ABP and ICP wave amplitudes which can be indicative of the state of cerebrovascular pressure regulation, and partly related to the ICP wave amplitude which can be indicative of the intracranial compliance. PMID:21349148

  4. An in silico framework to analyze the anisotropic shear wave mechanics in cardiac shear wave elastography

    NASA Astrophysics Data System (ADS)

    Caenen, Annette; Pernot, Mathieu; Peirlinck, Mathias; Mertens, Luc; Swillens, Abigail; Segers, Patrick

    2018-04-01

    Shear wave elastography (SWE) is a potential tool to non-invasively assess cardiac muscle stiffness. This study focused on the effect of the orthotropic material properties and mechanical loading on the performance of cardiac SWE, as it is known that these factors contribute to complex 3D anisotropic shear wave propagation. To investigate the specific impact of these complexities, we constructed a finite element model with an orthotropic material law subjected to different uniaxial stretches to simulate SWE in the stressed cardiac wall. Group and phase speed were analyzed in function of tissue thickness and virtual probe rotation angle. Tissue stretching increased the group and phase speed of the simulated shear wave, especially in the direction of the muscle fiber. As the model provided access to the true fiber orientation and material properties, we assessed the accuracy of two fiber orientation extraction methods based on SWE. We found a higher accuracy (but lower robustness) when extracting fiber orientations based on the location of maximal shear wave speed instead of the angle of the major axis of the ellipsoidal group speed surface. Both methods had a comparable performance for the center region of the cardiac wall, and performed less well towards the edges. Lastly, we also assessed the (theoretical) impact of pathology on shear wave physics and characterization in the model. It was found that SWE was able to detect changes in fiber orientation and material characteristics, potentially associated with cardiac pathologies such as myocardial fibrosis. Furthermore, the model showed clearly altered shear wave patterns for the fibrotic myocardium compared to the healthy myocardium, which forms an initial but promising outcome of this modeling study.

  5. Noninvasive diagnosis of right-sided extracardiac conduit obstruction by combined magnetic resonance imaging and continuous-wave Doppler echocardiography.

    PubMed

    Canter, C E; Gutierrez, F R; Molina, P; Hartmann, A F; Spray, T L

    1991-04-01

    Right-sided extracardiac conduits are frequently complicated by obstruction over time. We compared the utility of two-dimensional and Doppler echocardiography and magnetic resonance imaging in the diagnosis of postoperative right-sided obstruction with cardiac catheterization and angiography in 10 patients with xenograft or homograft conduits. Correlation (r = 0.95) between continuous-wave Doppler estimates and catheter pullback pressure gradients across the conduits was excellent. Echocardiography could only visualize five of 10 conduits in their entirety. Magnetic resonance imaging visualized all conduits and showed statistically significant (kappa = 0.58) agreement with angiography in the localization and estimation of severity of a variety of right-sided obstructions in these patients. However, flow voids created by the metallic ring around xenograft valves led to a false negative diagnosis of valvular stenosis in four patients when magnetic resonance imaging was used alone. Doppler studies correctly indicated obstruction in these patients. The combination of magnetic resonance imaging studies and continuous-wave Doppler echocardiography can be useful to noninvasively evaluate right-sided obstruction in postoperative patients with right-sided extracardiac conduits.

  6. Slow [Na+]i dynamics impacts arrhythmogenesis and spiral wave reentry in cardiac myocyte ionic model.

    PubMed

    Krogh-Madsen, Trine; Christini, David J

    2017-09-01

    Accumulation of intracellular Na + is gaining recognition as an important regulator of cardiac myocyte electrophysiology. The intracellular Na + concentration can be an important determinant of the cardiac action potential duration, can modulate the tissue-level conduction of excitation waves, and can alter vulnerability to arrhythmias. Mathematical models of cardiac electrophysiology often incorporate a dynamic intracellular Na + concentration, which changes much more slowly than the remaining variables. We investigated the dependence of several arrhythmogenesis-related factors on [Na + ] i in a mathematical model of the human atrial action potential. In cell simulations, we found that [Na + ] i accumulation stabilizes the action potential duration to variations in several conductances and that the slow dynamics of [Na + ] i impacts bifurcations to pro-arrhythmic afterdepolarizations, causing intermittency between different rhythms. In long-lasting tissue simulations of spiral wave reentry, [Na + ] i becomes spatially heterogeneous with a decreased area around the spiral wave rotation center. This heterogeneous region forms a functional anchor, resulting in diminished meandering of the spiral wave. Our findings suggest that slow, physiological, rate-dependent variations in [Na + ] i may play complex roles in cellular and tissue-level cardiac dynamics.

  7. Slow [Na+]i dynamics impacts arrhythmogenesis and spiral wave reentry in cardiac myocyte ionic model

    NASA Astrophysics Data System (ADS)

    Krogh-Madsen, Trine; Christini, David J.

    2017-09-01

    Accumulation of intracellular Na+ is gaining recognition as an important regulator of cardiac myocyte electrophysiology. The intracellular Na+ concentration can be an important determinant of the cardiac action potential duration, can modulate the tissue-level conduction of excitation waves, and can alter vulnerability to arrhythmias. Mathematical models of cardiac electrophysiology often incorporate a dynamic intracellular Na+ concentration, which changes much more slowly than the remaining variables. We investigated the dependence of several arrhythmogenesis-related factors on [Na+]i in a mathematical model of the human atrial action potential. In cell simulations, we found that [Na+]i accumulation stabilizes the action potential duration to variations in several conductances and that the slow dynamics of [Na+]i impacts bifurcations to pro-arrhythmic afterdepolarizations, causing intermittency between different rhythms. In long-lasting tissue simulations of spiral wave reentry, [Na+]i becomes spatially heterogeneous with a decreased area around the spiral wave rotation center. This heterogeneous region forms a functional anchor, resulting in diminished meandering of the spiral wave. Our findings suggest that slow, physiological, rate-dependent variations in [Na+]i may play complex roles in cellular and tissue-level cardiac dynamics.

  8. Impedance cardiography: a comparison of cardiac output vs waveform analysis for assessing left ventricular systolic dysfunction.

    PubMed

    DeMarzo, Arthur P; Kelly, Russell F; Calvin, James E

    2007-01-01

    Early detection of asymptomatic left ventricular systolic dysfunction (LVSD) is beneficial in managing heart failure. Recent studies have cast doubt on the usefulness of cardiac output as an indicator of LVSD. In impedance cardiography (ICG), the dZ/dt waveform has a systolic wave called the E wave. This study looked at measurements of the amplitude and area of the E wave compared with ICG-derived cardiac output, stroke volume, cardiac index, and stroke index as methods of assessing LVSD. ICG data were obtained from patients (n=26) admitted to a coronary care unit. Clinical LVSD severity was stratified into 4 groups (none, mild, moderate, and severe) based on echocardiography data and standard clinical assessment by a cardiologist blinded to ICG data. Statistical analysis showed that the E wave amplitude and area were better indicators of the level of LVSD than cardiac output, stroke volume, cardiac index, or stroke index. ICG waveform analysis has potential as a simple point-of-care test for detecting LVSD in asymptomatic patients at high risk for developing heart failure and for monitoring LVSD in patients being treated for heart failure.

  9. Clinical significance of fragmented QRS complexes or J waves in patients with idiopathic ventricular arrhythmias.

    PubMed

    Seong, Choong Sil; Gwag, Hye Bin; Hwang, Jin Kyung; Park, Seung Jung; Park, Kyoung-Min; Kim, June Soo; On, Young Keun

    2018-01-01

    Idiopathic ventricular fibrillation (IVF) can cause sudden cardiac death. Previous studies have reported that J waves and fragmented QRS complexes (f-QRS) are arrhythmogenic markers and predictors of cardiac events. We evaluated the prevalence and clinical significance of J waves and f-QRS in patients with IVF. We studied 81 patients who received an implantable cardioverter defibrillator (ICD) due to IVF between October 1999 and June 2015. We assessed the prevalence of J waves and f-QRS using electrocardiograms (ECGs). Patients were classified into three groups: J wave group (n = 35), f-QRS group (n = 20), or normal ECG group (n = 26). The control group included 81 subjects without heart disease who were matched for age, sex, and race. We compared syncope, sudden cardiac arrest, and appropriate ICD shock between the three groups. The follow-up duration was 4.1 years. J waves and f-QRS were more frequent in patients with IVF than in control subjects (43.2%, 21% vs. 24.7%, 19.7%, P < 0.001). Out of the three groups, clinical cardiac events were most frequent in the f-QRS group (50% vs. 45.7% vs. 11.5%, P = 0.028). A comparison of the combined group of J wave and f-QRS versus the normal ECG group revealed that the combined group had a higher frequency of clinical cardiac events than the normal ECG group (47.3% vs. 11.5%, respectively, P = 0.009). Patients with IVF had higher prevalence of f-QRS or J waves. And patients with f-QRS or J waves were at higher risk of recurrent ventricular fibrillation.

  10. Noncontact quantitative biomechanical characterization of cardiac muscle using shear wave imaging optical coherence tomography

    PubMed Central

    Wang, Shang; Lopez, Andrew L.; Morikawa, Yuka; Tao, Ge; Li, Jiasong; Larina, Irina V.; Martin, James F.; Larin, Kirill V.

    2014-01-01

    We report on a quantitative optical elastographic method based on shear wave imaging optical coherence tomography (SWI-OCT) for biomechanical characterization of cardiac muscle through noncontact elasticity measurement. The SWI-OCT system employs a focused air-puff device for localized loading of the cardiac muscle and utilizes phase-sensitive OCT to monitor the induced tissue deformation. Phase information from the optical interferometry is used to reconstruct 2-D depth-resolved shear wave propagation inside the muscle tissue. Cross-correlation of the displacement profiles at various spatial locations in the propagation direction is applied to measure the group velocity of the shear waves, based on which the Young’s modulus of tissue is quantified. The quantitative feature and measurement accuracy of this method is demonstrated from the experiments on tissue-mimicking phantoms with the verification using uniaxial compression test. The experiments are performed on ex vivo cardiac muscle tissue from mice with normal and genetically altered myocardium. Our results indicate this optical elastographic technique is useful as a noncontact tool to assist the cardiac muscle studies. PMID:25071943

  11. Aortic stiffness and the balance between cardiac oxygen supply and demand: the Rotterdam Study.

    PubMed

    Guelen, Ilja; Mattace-Raso, Francesco Us; van Popele, Nicole M; Westerhof, Berend E; Hofman, Albert; Witteman, Jacqueline Cm; Bos, Willem Jan W

    2008-06-01

    Aortic stiffness is an independent predictor of cardiovascular morbidity and mortality. We investigated whether aortic stiffness, estimated as aortic pulse wave velocity, is associated with decreased perfusion pressure estimated as the cardiac oxygen supply potential. Aortic stiffness and aortic pressure waves, reconstructed from finger blood pressure waves, were obtained in 2490 older adults within the framework of the Rotterdam Study, a large population-based study. Cardiac oxygen supply and demand were estimated using pulse wave analysis techniques, and related to aortic stiffness by linear regression analyses after adjustment for age, sex, mean arterial pressure and heart rate. Cardiac oxygen demand, estimated as the Systolic Pressure Time Index and the Rate Pressure Product, increased with increasing aortic stiffness [0.27 mmHg s (95% confidence interval: 0.21; 0.34)] and [42.2 mmHg/min (95% confidence interval: 34.1; 50.3)], respectively. Cardiac oxygen supply potential estimated as the Diastolic Pressure Time Index decreased [-0.70 mmHg s (95% confidence interval: -0.86; -0.54)] with aortic stiffening. Accordingly, the supply/demand ratio Diastolic Pressure Time Index/Systolic Pressure Time Index -1.11 (95% confidence interval: -0.14; -0.009) decreased with increasing aortic stiffness. Aortic stiffness is associated with estimates of increased cardiac oxygen demand and a decreased cardiac oxygen supply potential. These results may offer additional explanation for the relation between aortic stiffness and cardiovascular morbidity and mortality.

  12. Electrical wave propagation in an anisotropic model of the left ventricle based on analytical description of cardiac architecture.

    PubMed

    Pravdin, Sergey F; Dierckx, Hans; Katsnelson, Leonid B; Solovyova, Olga; Markhasin, Vladimir S; Panfilov, Alexander V

    2014-01-01

    We develop a numerical approach based on our recent analytical model of fiber structure in the left ventricle of the human heart. A special curvilinear coordinate system is proposed to analytically include realistic ventricular shape and myofiber directions. With this anatomical model, electrophysiological simulations can be performed on a rectangular coordinate grid. We apply our method to study the effect of fiber rotation and electrical anisotropy of cardiac tissue (i.e., the ratio of the conductivity coefficients along and across the myocardial fibers) on wave propagation using the ten Tusscher-Panfilov (2006) ionic model for human ventricular cells. We show that fiber rotation increases the speed of cardiac activation and attenuates the effects of anisotropy. Our results show that the fiber rotation in the heart is an important factor underlying cardiac excitation. We also study scroll wave dynamics in our model and show the drift of a scroll wave filament whose velocity depends non-monotonically on the fiber rotation angle; the period of scroll wave rotation decreases with an increase of the fiber rotation angle; an increase in anisotropy may cause the breakup of a scroll wave, similar to the mother rotor mechanism of ventricular fibrillation.

  13. Electrocardiography in two subspecies of manatee (Trichechus manatus latirostris and Trichechus manatus manatus)

    USGS Publications Warehouse

    Siegal-Willott, J.; Estrada, A.; Bonde, R.K.; Wong, A.; Estrada, D.J.; Harr, K.

    2006-01-01

    Electrocardiographic (ECG) measurements were recorded in two subspecies of awake, apparently healthy, wild manatees (Trichechus manatus latirostris and T. m. manatus) undergoing routine field examinations in Florida and Belize. Six unsedated juveniles (dependent and independent calves) and 6 adults were restrained in ventral recumbency for ECG measurements. Six lead ECGs were recorded for all manatees and the following parameters were determined: heart rate and rhythm; P, QRS, and T wave morphology, amplitude, and duration; and mean electrical axis (MEA). Statistical differences using a t-test for equality of means were determined. No statistical difference was seen based on sex or subspecies of manatees in the above measured criteria. Statistical differences existed in heart rate (P = 0.047), P wave duration (P = 0.019), PR interval (P = 0.025), and MEA (P = 0.021) between adult manatees and calves. Our findings revealed normal sinus rhythms, no detectable arrhythmias, prolonged PR and QT intervals, prolonged P wave duration, and small R wave amplitude as compared with cetacea and other marine mammals. This paper documents the techniques for and baseline recordings of ECGs in juvenile and adult free-living manatees. It also demonstrates that continual assessment of cardiac electrical activity in the awake manatee can be completed and can be used to aid veterinarians and biologists in routine health assessment, during procedures, and in detecting the presence of cardiac disease or dysfunction.

  14. Electrocardiography in two subspecies of manatee (Trichechus manatus latirostris and T. m. manatus).

    PubMed

    Siegal-Willott, Jessica; Estrada, Amara; Bonde, Robert; Wong, Arthur; Estrada, Daniel J; Harr, Kendal

    2006-12-01

    Electrocardiographic (ECG) measurements were recorded in two subspecies of awake, apparently healthy, wild manatees (Trichechus manatus latirostris and T. m. manatus) undergoing routine field examinations in Florida and Belize. Six unsedated juveniles (dependent and independent calves) and 6 adults were restrained in ventral recumbency for ECG measurements. Six lead ECGs were recorded for all manatees and the following parameters were determined: heart rate and rhythm; P, QRS, and T wave morphology, amplitude, and duration; and mean electrical axis (MEA). Statistical differences using a t-test for equality of means were determined. No statistical difference was seen based on sex or subspecies of manatees in the above measured criteria. Statistical differences existed in heart rate (P = 0.047), P wave duration (P = 0.019), PR interval (P = 0.025), and MEA (P = 0.021) between adult manatees and calves. Our findings revealed normal sinus rhythms, no detectable arrhythmias, prolonged PR and QT intervals, prolonged P wave duration, and small R wave amplitude as compared with cetacea and other marine mammals. This paper documents the techniques for and baseline recordings of ECGs in juvenile and adult free-living manatees. It also demonstrates that continual assessment of cardiac electrical activity in the awake manatee can be completed and can be used to aid veterinarians and biologists in routine health assessment, during procedures, and in detecting the presence of cardiac disease or dysfunction.

  15. Curvature Analysis of Cardiac Excitation Wavefronts

    DTIC Science & Technology

    2013-04-01

    required at this level either. To enable this kind of analysis, a type field is added to the polyline data structure, too. The downside of reusing the...GPU-based parallel methods. The wave curvature and the refractory period of the cardiac cells influence the motion of cardiac waves. The role of...propagation speed, the action potential duration, and the refractory period is studied. In the recent work of [26], multiple spirals and their

  16. New mechanism of spiral wave initiation in a reaction-diffusion-mechanics system.

    PubMed

    Weise, Louis D; Panfilov, Alexander V

    2011-01-01

    Spiral wave initiation in the heart muscle is a mechanism for the onset of dangerous cardiac arrhythmias. A standard protocol for spiral wave initiation is the application of a stimulus in the refractory tail of a propagating excitation wave, a region that we call the "classical vulnerable zone." Previous studies of vulnerability to spiral wave initiation did not take the influence of deformation into account, which has been shown to have a substantial effect on the excitation process of cardiomyocytes via the mechano-electrical feedback phenomenon. In this work we study the effect of deformation on the vulnerability of excitable media in a discrete reaction-diffusion-mechanics (dRDM) model. The dRDM model combines FitzHugh-Nagumo type equations for cardiac excitation with a discrete mechanical description of a finite-elastic isotropic material (Seth material) to model cardiac excitation-contraction coupling and stretch activated depolarizing current. We show that deformation alters the "classical," and forms a new vulnerable zone at longer coupling intervals. This mechanically caused vulnerable zone results in a new mechanism of spiral wave initiation, where unidirectional conduction block and rotation directions of the consequently initiated spiral waves are opposite compared to the mechanism of spiral wave initiation due to the "classical vulnerable zone." We show that this new mechanism of spiral wave initiation can naturally occur in situations that involve wave fronts with curvature, and discuss its relation to supernormal excitability of cardiac tissue. The concept of mechanically induced vulnerability may lead to a better understanding about the onset of dangerous heart arrhythmias via mechano-electrical feedback.

  17. Implantable telemetry for small animals

    NASA Astrophysics Data System (ADS)

    1982-03-01

    A series of totally implantable telemetry devices for use in measuring deep body parameters in small animals were developed. Under a collaborative agreement with NASA, several of these systems; the continuous wave Doppler ultrasonic flowmeter, the multichannel telemetry system, and the inductively-powered dual channel cardiac pacer were evaluated in a series of ten mongrel dogs (15 to 20 kg.). These systems were used to measure ascending aortic and coronary blood flow, aortic pressure, and subcutaneous EKG.

  18. Implantable telemetry for small animals

    NASA Technical Reports Server (NTRS)

    1982-01-01

    A series of totally implantable telemetry devices for use in measuring deep body parameters in small animals were developed. Under a collaborative agreement with NASA, several of these systems; the continuous wave Doppler ultrasonic flowmeter, the multichannel telemetry system, and the inductively-powered dual channel cardiac pacer were evaluated in a series of ten mongrel dogs (15 to 20 kg.). These systems were used to measure ascending aortic and coronary blood flow, aortic pressure, and subcutaneous EKG.

  19. Predicting sudden cardiac death from T wave alternans of the surface electrocardiogram: promise and pitfalls

    NASA Technical Reports Server (NTRS)

    Rosenbaum, D. S.; Albrecht, P.; Cohen, R. J.

    1996-01-01

    Sudden cardiac death remains a preeminent public health problem. Despite advances in preventative treatment for patients known to be at risk, to date we have been able to identify, and thus treat, only a small minority of these patients. Therefore, there is a major need to develop noninvasive diagnostic technologies to identify patients at risk. Recent studies have demonstrated that measurement of microvolt-level T wave alternans is a promising technique for the accurate identification of patients at risk for ventricular arrhythmias and sudden cardiac death. In this article, we review the clinical data establishing the relationship between microvolt T wave alternans and susceptibility to ventricular arrhythmias. We also review the methods and technology that have been developed to measure microvolt levels of T wave alternans noninvasively in broad populations of ambulatory patients. In particular, we examine techniques that permit the accurate measurement of T wave alternans during exercise stress testing.

  20. Exercise training in adults with repaired tetralogy of Fallot: A randomized controlled pilot study of continuous versus interval training.

    PubMed

    Novaković, Marko; Prokšelj, Katja; Rajkovič, Uroš; Vižintin Cuderman, Tjaša; Janša Trontelj, Katja; Fras, Zlatko; Jug, Borut

    2018-03-15

    Adults with repaired tetralogy of Fallot (ToF) have impaired exercise capacity, vascular and cardiac autonomic function, and quality of life (QoL). Specific effects of high-intensity interval or moderate continuous exercise training on these parameters in adults with repaired ToF remain unknown. Thirty adults with repaired ToF were randomized to either high-intensity interval, moderate intensity continuous training (36 sessions, 2-3 times a week) or usual care (no supervised exercise). Exercise capacity, flow-mediated vasodilation, pulse wave velocity, NT-proBNP and fibrinogen levels, heart rate variability and recovery, and QoL (SF-36 questionnaire) were determined at baseline and after the intervention period. Twenty-seven patients (mean age 39±9years, 63% females, 9 from each group) completed this pilot study. Both training groups improved in at least some parameters of cardiovascular health compared to no exercise. Interval-but not continuous-training improved VO2peak (21.2 to 22.9ml/kg/min, p=0.004), flow-mediated vasodilation (8.4 to 12.9%, p=0.019), pulse wave velocity (5.4 to 4.8m/s, p=0.028), NT-proBNP (202 to 190ng/L, p=0.032) and fibrinogen levels (2.67 to 2.46g/L, p=0.018). Conversely, continuous-but not interval-training improved heart rate variability (low-frequency domain, 0.32 to 0.22, p=0.039), heart rate recovery after 2min post-exercise (40 to 47 beats, p=0.023) and mental domain of SF-36 (87 to 95, p=0.028). Both interval and continuous exercise training modalities were safe. Interval training seems more efficacious in improving exercise capacity, vascular function, NT-proBNP and fibrinogen levels, while continuous training seems more efficacious in improving cardiac autonomic function and QoL. (Clinicaltrials.gov, NCT02643810). Copyright © 2018 Elsevier Ireland Ltd. All rights reserved.

  1. The Effect of Atrial Fibrillation Ablation Techniques on P Wave Duration and P Wave Dispersion.

    PubMed

    Furniss, Guy O; Panagopoulos, Dimitrios; Kanoun, Sadeek; Davies, Edward J; Tomlinson, David R; Haywood, Guy A

    2018-02-14

    A reduction in surface electrocardiogram (ECG) P wave duration and dispersion is associated with improved outcomes in atrial fibrillation ablation. We investigated the effects of different ablation strategies on P wave duration and dispersion, hypothesising that extensive left atrial (LA) ablation with left atrial posterior wall isolation would give a greater reduction in P wave duration than more limited ablation techniques. A retrospective analysis of ECGs from patients who have undergone atrial fibrillation (AF) ablation was performed and pre-procedural sinus rhythm ECGs were compared with the post procedure ECGs. Maximal P wave duration was measured in leads I or II, minimum P wave duration in any lead and values were calculated for P wave duration and dispersion. Left atrial dimensions and medications at the time of ECG were documented. Ablation strategies compared were; pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) and the persistent AF (PsAF) ablation strategies of pulmonary vein isolation plus additional linear lesions (Lines), left atrial posterior wall isolation via catheter (PWI) and left atrial posterior wall isolation via staged surgical and catheter ablation (Hybrid). Sixty-nine patients' ECGs were analysed: 19 PVI, 21 Lines, 14 PWI, 15 Hybrid. Little correlation was seen between pre-procedure left atrial size and P wave duration (r=0.24) but LA size and P wave duration was larger in PsAF patients. A significant difference was seen in P wave reduction driven by Hybrid AF ablation (p<0.005) and Lines (<0.02). There was no difference amongst P wave dispersion between groups but the largest reduction was seen in the Hybrid ablation group. P wave duration increased with duration of continuous atrial fibrillation. Hybrid AF ablation significantly reduced P wave duration and dispersion compared to other ablation strategies including posterior wall isolation via catheter despite this being the same lesion set. Copyright © 2018 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  2. Arrhythmia during extracorporeal shock wave lithotripsy.

    PubMed

    Zeng, Z R; Lindstedt, E; Roijer, A; Olsson, S B

    1993-01-01

    A prospective study of arrhythmia during extracorporeal shock wave lithotripsy (ESWL) was performed in 50 patients, using an EDAP LT01 piezoelectric lithotriptor. The 12-lead standard ECG was recorded continuously for 10 min before and during treatment. One or more atrial and/or ventricular ectopic beats occurred during ESWL in 15 cases (30%). The occurrence of arrhythmia was similar during right-sided and left-sided treatment. One patient developed multifocal ventricular premature beats and ventricular bigeminy; another had cardiac arrest for 13.5 s. It was found that various irregularities of the heart rhythm can be caused even by treatment with a lithotriptor using piezoelectric energy to create the shock wave. No evidence was found, however, that the shock wave itself rather than vagal activation and the action of sedo-analgesia was the cause of the arrhythmia. For patients with severe underlying heart disease and a history of complex arrhythmia, we suggest that the ECG be monitored during treatment. In other cases, we have found continuous monitoring of oxygen saturation and pulse rate with a pulse oximeter to be perfectly reliable for raising the alarm when depression of respiration and vaso-vagal reactions occur.

  3. Scroll-Wave Dynamics in Human Cardiac Tissue: Lessons from a Mathematical Model with Inhomogeneities and Fiber Architecture

    PubMed Central

    Majumder, Rupamanjari; Nayak, Alok Ranjan; Pandit, Rahul

    2011-01-01

    Cardiac arrhythmias, such as ventricular tachycardia (VT) and ventricular fibrillation (VF), are among the leading causes of death in the industrialized world. These are associated with the formation of spiral and scroll waves of electrical activation in cardiac tissue; single spiral and scroll waves are believed to be associated with VT whereas their turbulent analogs are associated with VF. Thus, the study of these waves is an important biophysical problem. We present a systematic study of the combined effects of muscle-fiber rotation and inhomogeneities on scroll-wave dynamics in the TNNP (ten Tusscher Noble Noble Panfilov) model for human cardiac tissue. In particular, we use the three-dimensional TNNP model with fiber rotation and consider both conduction and ionic inhomogeneities. We find that, in addition to displaying a sensitive dependence on the positions, sizes, and types of inhomogeneities, scroll-wave dynamics also depends delicately upon the degree of fiber rotation. We find that the tendency of scroll waves to anchor to cylindrical conduction inhomogeneities increases with the radius of the inhomogeneity. Furthermore, the filament of the scroll wave can exhibit drift or meandering, transmural bending, twisting, and break-up. If the scroll-wave filament exhibits weak meandering, then there is a fine balance between the anchoring of this wave at the inhomogeneity and a disruption of wave-pinning by fiber rotation. If this filament displays strong meandering, then again the anchoring is suppressed by fiber rotation; also, the scroll wave can be eliminated from most of the layers only to be regenerated by a seed wave. Ionic inhomogeneities can also lead to an anchoring of the scroll wave; scroll waves can now enter the region inside an ionic inhomogeneity and can display a coexistence of spatiotemporal chaos and quasi-periodic behavior in different parts of the simulation domain. We discuss the experimental implications of our study. PMID:21483682

  4. Electrical Wave Propagation in an Anisotropic Model of the Left Ventricle Based on Analytical Description of Cardiac Architecture

    PubMed Central

    Pravdin, Sergey F.; Dierckx, Hans; Katsnelson, Leonid B.; Solovyova, Olga; Markhasin, Vladimir S.; Panfilov, Alexander V.

    2014-01-01

    We develop a numerical approach based on our recent analytical model of fiber structure in the left ventricle of the human heart. A special curvilinear coordinate system is proposed to analytically include realistic ventricular shape and myofiber directions. With this anatomical model, electrophysiological simulations can be performed on a rectangular coordinate grid. We apply our method to study the effect of fiber rotation and electrical anisotropy of cardiac tissue (i.e., the ratio of the conductivity coefficients along and across the myocardial fibers) on wave propagation using the ten Tusscher–Panfilov (2006) ionic model for human ventricular cells. We show that fiber rotation increases the speed of cardiac activation and attenuates the effects of anisotropy. Our results show that the fiber rotation in the heart is an important factor underlying cardiac excitation. We also study scroll wave dynamics in our model and show the drift of a scroll wave filament whose velocity depends non-monotonically on the fiber rotation angle; the period of scroll wave rotation decreases with an increase of the fiber rotation angle; an increase in anisotropy may cause the breakup of a scroll wave, similar to the mother rotor mechanism of ventricular fibrillation. PMID:24817308

  5. Electromechanical vortex filaments during cardiac fibrillation

    NASA Astrophysics Data System (ADS)

    Christoph, J.; Chebbok, M.; Richter, C.; Schröder-Schetelig, J.; Bittihn, P.; Stein, S.; Uzelac, I.; Fenton, F. H.; Hasenfuß, G.; Gilmour, R. F., Jr.; Luther, S.

    2018-03-01

    The self-organized dynamics of vortex-like rotating waves, which are also known as scroll waves, are the basis of the formation of complex spatiotemporal patterns in many excitable chemical and biological systems. In the heart, filament-like phase singularities that are associated with three-dimensional scroll waves are considered to be the organizing centres of life-threatening cardiac arrhythmias. The mechanisms that underlie the onset, maintenance and control of electromechanical turbulence in the heart are inherently three-dimensional phenomena. However, it has not previously been possible to visualize the three-dimensional spatiotemporal dynamics of scroll waves inside cardiac tissues. Here we show that three-dimensional mechanical scroll waves and filament-like phase singularities can be observed deep inside the contracting heart wall using high-resolution four-dimensional ultrasound-based strain imaging. We found that mechanical phase singularities co-exist with electrical phase singularities during cardiac fibrillation. We investigated the dynamics of electrical and mechanical phase singularities by simultaneously measuring the membrane potential, intracellular calcium concentration and mechanical contractions of the heart. We show that cardiac fibrillation can be characterized using the three-dimensional spatiotemporal dynamics of mechanical phase singularities, which arise inside the fibrillating contracting ventricular wall. We demonstrate that electrical and mechanical phase singularities show complex interactions and we characterize their dynamics in terms of trajectories, topological charge and lifetime. We anticipate that our findings will provide novel perspectives for non-invasive diagnostic imaging and therapeutic applications.

  6. Nonlinear physics of electrical wave propagation in the heart: a review

    NASA Astrophysics Data System (ADS)

    Alonso, Sergio; Bär, Markus; Echebarria, Blas

    2016-09-01

    The beating of the heart is a synchronized contraction of muscle cells (myocytes) that is triggered by a periodic sequence of electrical waves (action potentials) originating in the sino-atrial node and propagating over the atria and the ventricles. Cardiac arrhythmias like atrial and ventricular fibrillation (AF,VF) or ventricular tachycardia (VT) are caused by disruptions and instabilities of these electrical excitations, that lead to the emergence of rotating waves (VT) and turbulent wave patterns (AF,VF). Numerous simulation and experimental studies during the last 20 years have addressed these topics. In this review we focus on the nonlinear dynamics of wave propagation in the heart with an emphasis on the theory of pulses, spirals and scroll waves and their instabilities in excitable media with applications to cardiac modeling. After an introduction into electrophysiological models for action potential propagation, the modeling and analysis of spatiotemporal alternans, spiral and scroll meandering, spiral breakup and scroll wave instabilities like negative line tension and sproing are reviewed in depth and discussed with emphasis on their impact for cardiac arrhythmias.

  7. Measurement of viscoelastic properties of in vivo swine myocardium using Lamb Wave Dispersion Ultrasound Vibrometry (LDUV)

    PubMed Central

    Urban, Matthew W.; Pislaru, Cristina; Nenadic, Ivan Z.; Kinnick, Randall R.; Greenleaf, James F.

    2012-01-01

    Viscoelastic properties of the myocardium are important for normal cardiac function and may be altered by disease. Thus, quantification of these properties may aid with evaluation of the health of the heart. Lamb Wave Dispersion Ultrasound Vibrometry (LDUV) is a shear wave-based method that uses wave velocity dispersion to measure the underlying viscoelastic material properties of soft tissue with plate-like geometries. We tested this method in eight pigs in an open-chest preparation. A mechanical actuator was used to create harmonic, propagating mechanical waves in the myocardial wall. The motion was tracked using a high frame rate acquisition sequence, typically 2500 Hz. The velocities of wave propagation were measured over the 50–400 Hz frequency range in 50 Hz increments. Data were acquired over several cardiac cycles. Dispersion curves were fit with a viscoelastic, anti-symmetric Lamb wave model to obtain estimates of the shear elasticity, μ1, and viscosity, μ2 as defined by the Kelvin-Voigt rheological model. The sensitivity of the Lamb wave model was also studied using simulated data. We demonstrated that wave velocity measurements and Lamb wave theory allow one to estimate the variation of viscoelastic moduli of the myocardial walls in vivo throughout the course of the cardiac cycle. PMID:23060325

  8. Congenital cardiac disease in dogs.

    PubMed

    McCaw, D; Aronson, E

    1984-07-01

    Pulmonic stenosis is caused by a malformed pulmonic valve, stricture of the right ventricular outflow tract or stricture of the pulmonary artery. English Bulldogs, Beagles, Samoyeds, Fox Terriers and Chihuahuas are predisposed. Clinical signs in severely affected dogs include exercise intolerance, stunting, dyspnea, syncope and ascites. Auscultation reveals a high-frequency, crescendo-decrescendo murmur during systole, loudest over the left side of the thorax, near the sternal cardiac border. An ECG may reveal a right-axis deviation of greater than 120 degrees, S waves in leads I, II and III, deep S waves in CV6LL, CV6LU and V10, Q waves deeper than 0.5 mv in leads II, III and AVF, and positive T waves in lead V10. Plain film LAT thoracic radiographs reveal an elevated carina, increased sternal contact of the heart, loss of the cranial cardiac waist and a widened cardiac silhouette, with normal pulmonary vasculature. A DV projection reveals an inverted "D" shape of the right ventricle and a pulmonary artery bulge. A nonselective angiocardiogram reveals poststenotic dilation of the main pulmonary artery. Treatment involves surgical correction of the stenosis.

  9. Continuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals ByUsing Microsoft Visual C Sharp.

    PubMed

    Younessi Heravi, M A; Khalilzadeh, M A; Joharinia, S

    2014-03-01

    One of the main problems especially in operating room and monitoring devices is measurement of Blood Pressure (BP) by sphygmomanometer cuff. Objective :In this study we designed a new method to measure BP changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. This will be achieved by extraction of the time difference between each cardiac cycle and a relative pulse wave. Finger pulse and ECG signals in lead I were recorded by a monitoring device. The output of monitoring device wasinserted in a computer by serial network communication. A software interface (Microsoft Visual C#.NET ) was used to display and process the signals in the computer. Time difference between each cardiac cycle and pulse signal was calculated throughout R wave detection in ECG and peak of pulse signal by the software. The relation between time difference in two waves and BP was determined then the coefficients of equation were obtained in different physical situations. The results of estimating BP were compared with the results of sphygmomanometer method and the error rate was calculated. In this study, 25 subjects participated among them 15 were male and 10 were female. The results showed that BP was linearly related to time difference. Average of coefficient correlation was 0.9±0.03 for systolic and 0.82±0.04 for diastolic blood pressure. The highest error percentage was calculated 8% for male and 11% for female group. Significant difference was observed between the different physical situation and arm movement changes. The relationship between time difference and age was estimated in a linear relationship with a correlation coefficient of 0.76. By determining linear relation values with high accuracy, BP can be measured with insignificant error. Therefore it can be suggested as a new method to measure the blood pressure continuously.

  10. Formation of virtual isthmus: A new scenario of spiral wave death after a decrease in excitability

    NASA Astrophysics Data System (ADS)

    Erofeev, I. S.; Agladze, K. I.

    2015-11-01

    Termination of rotating (spiral) waves or reentry is crucial when fighting with the most dangerous cardiac tachyarrhythmia. To increase the efficiency of the antiarrhythmic drugs as well as finding new prospective ones it is decisive to know the mechanisms how they act and influence the reentry dynamics. The most popular view on the mode of action of the contemporary antiarrhythmic drugs is that they increase the core of the rotating wave (reentry) to that extent that it is not enough space in the real heart for the reentry to exist. Since the excitation in cardiac cells is essentially change of the membrane potential, it relies on the functioning of the membrane ion channels. Thus, membrane ion channels serve as primary targets for the substances, which may serve as antiarrhythmics. At least, the entire group of antiarrhythmics class I (modulating activity of sodium channels) and partially class IV (modulating activity of calcium channels) are believed to destabilize and terminate reentry by decreasing the excitability of cardiac tissue. We developed an experimental model employing cardiac tissue culture and photosensitizer (AzoTAB) to study the process of the rotating wave termination while decreasing the excitability of the tissue. A new scenario of spiral wave cessation was observed: an asymmetric growth of the rotating wave core and subsequent formation of a virtual isthmus, which eventually caused a conduction block and the termination of the reentry.

  11. Biomarkers of Atrial Cardiopathy and Atrial Fibrillation Detection on Mobile Outpatient Continuous Telemetry After Embolic Stroke of Undetermined Source.

    PubMed

    Sebasigari, Denise; Merkler, Alexander; Guo, Yang; Gialdini, Gino; Kummer, Benjamin; Hemendinger, Morgan; Song, Christopher; Chu, Antony; Cutting, Shawna; Silver, Brian; Elkind, Mitchell S V; Kamel, Hooman; Furie, Karen L; Yaghi, Shadi

    2017-06-01

    Biomarkers of atrial dysfunction or "cardiopathy" are associated with embolic stroke risk. However, it is unclear if this risk is mediated by undiagnosed paroxysmal atrial fibrillation or flutter (AF). We aim to determine whether atrial cardiopathy biomarkers predict AF on continuous heart-rhythm monitoring after embolic stroke of undetermined source (ESUS). This was a single-center retrospective study including all patients with ESUS undergoing 30 days of ambulatory heart-rhythm monitoring to look for AF between January 1, 2013 and December 31, 2015. We reviewed medical records for clinical, radiographic, and cardiac variables. The primary outcome was a new diagnosis of AF detected during heart-rhythm monitoring. The primary predictors were atrial biomarkers: left atrial diameter on echocardiography, P-wave terminal force in electrocardiogram (ECG) lead V1, and P wave - R wave (PR) interval on ECG. A multiple logistic regression model was used to assess the relationship between atrial biomarkers and AF detection. Among 196 eligible patients, 23 (11.7%) were diagnosed with AF. In unadjusted analyses, patients with AF were older (72.4 years versus 61.4 years, P < .001) and had larger left atrial diameter (39.2 mm versus 35.7 mm, P = .03). In a multivariable model, the only predictor of AF was age ≥ 60 years (odds ratio, 3.0; 95% CI, 1.06-8.5; P = .04). Atrial biomarkers were weakly associated with AF after ESUS. This suggests that previously reported associations between these markers and stroke may reflect independent cardiac pathways leading to stroke. Prospective studies are needed to investigate these mechanisms. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  12. Success of spiral wave unpinning from heterogeneity in a cardiac tissue depends on its boundary conditions

    NASA Astrophysics Data System (ADS)

    Kachalov, V. N.; Tsvelaya, V. A.; Kudryashova, N. N.; Agladze, K. I.

    2017-11-01

    The mechanism of the low voltage defibrillation is based on the drift of the spiral wave induced by a high frequency wave train. In the process, it is first necessary to unpin the wave from the stabilizing obstacle. We study the conditions of unpinning of a rotating wave anchored to the defect by posing the main accent on the boundary conditions of it. The computer simulations performed using the Korhonen model showed that the fluxes through the border of the defect in the cardiac tissue can significantly modify the excitation pattern, and the working frequency gap for the unpinning of reentry waves could be substantially reduced, making overdrive pacing procedure less effective or practically inapplicable.

  13. Nonlinear excited waves on the interventricular septum

    NASA Astrophysics Data System (ADS)

    Bekki, Naoaki; Harada, Yoshifumi; Kanai, Hiroshi

    2012-11-01

    Using a novel ultrasonic noninvasive imaging method, we observe some phase singularities in propagating excited waves on a human cardiac interventricular septum (IVS) for a healthy young male. We present a possible physical model explaining one-dimensional dynamics of phase singularities in nonlinearly excited waves on the IVS. We show that at least one of the observed phase singularities in the excited waves on the IVS can be explained by the Bekki-Nozaki hole solution of the complex Ginzburg-Landau equation without any adjustable parameters. We conclude that the complex Ginzburg-Landau equation is such a suitable model for one-dimensional dynamics of cardiac phase singularities in nonlinearly excited waves on the IVS.

  14. Determinants and genesis of canine pneumocardiogram.

    PubMed

    Reitan, J A; Warpinski, M A; Martucci, R W

    1978-01-01

    The pneumocardiogram measures the to-and-fro movement of gas from the lung with each heartbeat during apnea. Six mongrel dogs were prepared with chronic ascending aortic or pulmonary artery flow probes, corresponding occlusion cuffs and intraventricular pressure transducers. Under halothane anesthesia, the flow pneumocardiogram (PnCG) and its time derivative (acceleration pneumocardiogram or dPn/dt) were transduced during apnea by a small high-gain pneumotachograph. All variables were recorded on paper. The effects on the pneumocardiogram of great vessel occlusion, changes in cardiac loading, small airway patency, and chest wall integrity were investigated. Four of the animals were treated subsequently to produce a chemical cardiac denervation and restudied. The systolic component of the dPn/dt which correlates with myocardial contractility (IJ wave) was dependent primarily on left ventricular (LV) ejection, markedly affected by cardiac preload and modified by afterload changes to a lesser degree. Small airway closure obliterated the wave form, while opening the chest wall attenuated the dPn/dt IJ wave by 25%. This study shows the dPn/dt IJ wave is anatomically related to LV performance and responds to changes in LV function similar to other noninvasive cardiac measurements.

  15. Rotors and the Dynamics of Cardiac Fibrillation

    PubMed Central

    Pandit, Sandeep V.; Jalife, José

    2013-01-01

    The objective of this article is to present a broad review on the role of cardiac electrical rotors and their accompanying spiral waves in the mechanism of cardiac fibrillation. At the outset, we present a brief historical overview regarding reentry, and then discuss the basic concepts and terminologies pertaining to rotors and their initiation. Thereafter, the intrinsic properties of rotors and spiral waves, including phase singularities, wavefront curvature and dominant frequency maps are discussed. The implications of rotor dynamics for the spatio-temporal organization of fibrillation, independent of the species being studied are touched upon next. The knowledge gained regarding the role of cardiac structure in the initiation and/or maintenance of rotors and the ionic bases of spiral waves in the last two decades, and its significance for drug therapy is reviewed subsequently. We conclude by looking at recent evidence suggesting that rotors are critical in sustaining both atrial and ventricular fibrillation (AF, VF) in the human heart, and its implications for treatment with radio-frequency ablation. PMID:23449547

  16. High Contrast Ultrafast Imaging of the Human Heart

    PubMed Central

    Papadacci, Clement; Pernot, Mathieu; Couade, Mathieu; Fink, Mathias; Tanter, Mickael

    2014-01-01

    Non-invasive ultrafast imaging for human cardiac applications is a big challenge to image intrinsic waves such as electromechanical waves or remotely induced shear waves in elastography imaging techniques. In this paper we propose to perform ultrafast imaging of the heart with adapted sector size by using diverging waves emitted from a classical transthoracic cardiac phased array probe. As in ultrafast imaging with plane wave coherent compounding, diverging waves can be summed coherently to obtain high-quality images of the entire heart at high frame rate in a full field-of-view. To image shear waves propagation at high SNR, the field-of-view can be adapted by changing the angular aperture of the transmitted wave. Backscattered echoes from successive circular wave acquisitions are coherently summed at every location in the image to improve the image quality while maintaining very high frame rates. The transmitted diverging waves, angular apertures and subapertures size are tested in simulation and ultrafast coherent compounding is implemented on a commercial scanner. The improvement of the imaging quality is quantified in phantom and in vivo on human heart. Imaging shear wave propagation at 2500 frame/s using 5 diverging waves provides a strong increase of the Signal to noise ratio of the tissue velocity estimates while maintaining a high frame rate. Finally, ultrafast imaging with a 1 to 5 diverging waves is used to image the human heart at a frame rate of 900 frames/s over an entire cardiac cycle. Thanks to spatial coherent compounding, a strong improvement of imaging quality is obtained with a small number of transmitted diverging waves and a high frame rate, which allows imaging the propagation of electromechanical and shear waves with good image quality. PMID:24474135

  17. Pulse Wave Transit Time Measurements of Cardiac Output in Septic Shock Patients: A Comparison of the Estimated Continuous Cardiac Output System with Transthoracic Echocardiography.

    PubMed

    Feissel, Marc; Aho, Ludwig Serge; Georgiev, Stefan; Tapponnier, Romain; Badie, Julio; Bruyère, Rémi; Quenot, Jean-Pierre

    2015-01-01

    We determined reliability of cardiac output (CO) measured by pulse wave transit time cardiac output system (esCCO system; COesCCO) vs transthoracic echocardiography (COTTE) in mechanically ventilated patients in the early phase of septic shock. A secondary objective was to assess ability of esCCO to detect change in CO after fluid infusion. Mechanically ventilated patients admitted to the ICU, aged >18 years, in sinus rhythm, in the early phase of septic shock were prospectively included. We performed fluid infusion of 500 ml of crystalloid solution over 20 minutes and recorded CO by EsCCO and TTE immediately before (T0) and 5 minutes after (T1) fluid administration. Patients were divided into 2 groups (responders and non-responders) according to a threshold of 15% increase in COTTE in response to volume expansion. In total, 25 patients were included, average 64±15 years, 15 (60%) were men. Average SAPSII and SOFA scores were 55±21.3 and 13±2, respectively. ICU mortality was 36%. Mean cardiac output at T0 was 5.8±1.35 L/min by esCCO and 5.27±1.17 L/min by COTTE. At T1, respective values were 6.63 ± 1.57 L/min for esCCO and 6.10±1.29 L/min for COTTE. Overall, 12 patients were classified as responders, 13 as non-responders by the reference method. A threshold of 11% increase in COesCCO was found to discriminate responders from non-responders with a sensitivity of 83% (95% CI, 0.52-0.98) and a specificity of 77% (95% CI, 0.46-0.95). We show strong correlation esCCO and echocardiography for measuring CO, and change in CO after fluid infusion in ICU patients.

  18. Predictive role of P-wave axis abnormalities in secondary cardiovascular prevention.

    PubMed

    Lazzeroni, Davide; Bini, Matteo; Camaiora, Umberto; Castiglioni, Paolo; Moderato, Luca; Ugolotti, Pietro Tito; Brambilla, Lorenzo; Brambilla, Valerio; Coruzzi, Paolo

    2017-12-01

    Background Abnormal P-wave axis has been correlated with an increased risk of all-cause and cardiovascular mortality in a general population. We aimed to evaluate the prognostic role of abnormal P-wave axis in patients undergoing myocardial revascularisation or cardiac valve surgery. Methods We considered data of 810 patients with available P-wave axis measure from a prospective monocentric registry of patients undergoing cardiovascular rehabilitation. A total of 436 patients (54%) underwent myocardial revascularisation, 253 (31%) valve surgery, 71 (9%) combined valve and coronary artery bypass graft surgery and 50 (6%) cardiac surgery for other cardiovascular disease. Mean follow-up was 47 ± 27 months. Results Over the whole group, P-wave axis was 43.8° ± 27.5° and an abnormal P-wave axis was found in 94 patients (12%). The risk of overall (hazard ratio (HR) 2.5, 95% confidence interval (CI) 1.6-4.0, P < 0.001) and cardiovascular mortality (HR 2.9, 95% CI 1.5-5.8, P = 0.002) was significantly higher in patients with abnormal P-wave axis even after adjustment for age, other electrocardiographic variables (PR, QRS, QTc intervals), left ventricular ejection fraction and left atrial volume index. After dividing the population according to the type of disease, patients with abnormal P-wave axis and ischaemic heart disease had 3.9-fold higher risk of cardiovascular mortality (HR 3.9, 95% CI 1.3-12.1, P = 0.017), while a 2.2-fold higher risk of cardiovascular mortality (HR 3.6, 95% CI 1.3-10.1, P = 0.015) was found in those with cardiac valve disease. Conclusion An abnormal P-wave axis represents an independent predictor of both overall and cardiovascular mortality in patients undergoing myocardial revascularisation or cardiac valve surgery.

  19. Computational approaches to understand cardiac electrophysiology and arrhythmias

    PubMed Central

    Roberts, Byron N.; Yang, Pei-Chi; Behrens, Steven B.; Moreno, Jonathan D.

    2012-01-01

    Cardiac rhythms arise from electrical activity generated by precisely timed opening and closing of ion channels in individual cardiac myocytes. These impulses spread throughout the cardiac muscle to manifest as electrical waves in the whole heart. Regularity of electrical waves is critically important since they signal the heart muscle to contract, driving the primary function of the heart to act as a pump and deliver blood to the brain and vital organs. When electrical activity goes awry during a cardiac arrhythmia, the pump does not function, the brain does not receive oxygenated blood, and death ensues. For more than 50 years, mathematically based models of cardiac electrical activity have been used to improve understanding of basic mechanisms of normal and abnormal cardiac electrical function. Computer-based modeling approaches to understand cardiac activity are uniquely helpful because they allow for distillation of complex emergent behaviors into the key contributing components underlying them. Here we review the latest advances and novel concepts in the field as they relate to understanding the complex interplay between electrical, mechanical, structural, and genetic mechanisms during arrhythmia development at the level of ion channels, cells, and tissues. We also discuss the latest computational approaches to guiding arrhythmia therapy. PMID:22886409

  20. Correlation of Electrocardiographic Changes with Cardiac Magnetic Resonance Findings in Patients with Hypertrophic Cardiomyopathy

    PubMed Central

    Paixão, Gabriela Miana de Mattos; Veronesi, Horácio Eduardo; da Silva, Halsted Alarcão Gomes Pereira; de Alencar Neto, José Nunes; Maldi, Carolina de Paulo; Aguiar Filho, Luciano de Figueiredo; Pinto, Ibrahim Masciarelli Francisco; de França, Francisco Faustino de Albuquerque Carneiro; Correia, Edileide de Barros

    2018-01-01

    Background Electrocardiogram is the initial test in the investigation of heart disease. Electrocardiographic changes in hypertrophic cardiomyopathy have no set pattern, and correlates poorly with echocardiographic findings. Cardiac magnetic resonance imaging has been gaining momentum for better assessment of hypertrophy, as well as the detection of myocardial fibrosis. Objectives To correlate the electrocardiographic changes with the location of hypertrophy in hypertrophic cardiomyopathy by cardiac magnetic resonance. Methods This descriptive cross-sectional study evaluated 68 patients with confirmed diagnosis of hypertrophic cardiomyopathy by cardiac magnetic resonance. The patients’ electrocardiogram was compared with the location of the greatest myocardial hypertrophy by cardiac magnetic resonance. Statistical significance level of 5% and 95% confidence interval were adopted. Results Of 68 patients, 69% had septal hypertrophy, 21% concentric and 10% apical hypertrophies. Concentric hypertrophy showed the greatest myocardial fibrosis mass (p < 0.001) and the greatest R wave size in D1 (p = 0.0280). The amplitudes of R waves in V5 and V6 (p = 0.0391, p = 0.0148) were higher in apical hypertrophy, with statistical significance. Apical hypertrophy was also associated with higher T wave negativity in D1, V5 and V6 (p < 0.001). Strain pattern was found in 100% of the patients with apical hypertrophy (p < 0.001). Conclusion The location of myocardial hypertrophy by cardiac magnetic resonance can be correlated with electrocardiographic changes, especially for apical hypertrophy. PMID:29538524

  1. A visible light imaging device for cardiac rate detection with reduced effect of body movement

    NASA Astrophysics Data System (ADS)

    Jiang, Xiaotian; Liu, Ming; Zhao, Yuejin

    2014-09-01

    A visible light imaging system to detect human cardiac rate is proposed in this paper. A color camera and several LEDs, acting as lighting source, were used to avoid the interference of ambient light. From people's forehead, the cardiac rate could be acquired based on photoplethysmography (PPG) theory. The template matching method was used after the capture of video. The video signal was discomposed into three signal channels (RGB) and the region of interest was chosen to take the average gray value. The green channel signal could provide an excellent waveform of pulse wave on the account of green lights' absorptive characteristics of blood. Through the fast Fourier transform, the cardiac rate was exactly achieved. But the research goal was not just to achieve the cardiac rate accurately. With the template matching method, the effects of body movement are reduced to a large extent, therefore the pulse wave can be detected even while people are in the moving state and the waveform is largely optimized. Several experiments are conducted on volunteers, and the results are compared with the ones gained by a finger clamped pulse oximeter. The contrast results between these two ways are exactly agreeable. This method to detect the cardiac rate and the pulse wave largely reduces the effects of body movement and can probably be widely used in the future.

  2. Modulation of cytosolic and intra-sarcoplasmic reticulum calcium waves by calsequestrin in rat cardiac myocytes

    PubMed Central

    Kubalova, Zuzana; Györke, Inna; Terentyeva, Radmila; Viatchenko-Karpinski, Serge; Terentyev, Dmitry; Williams, Simon C; Györke, Sandor

    2004-01-01

    Waves of Ca2+-induced Ca2+ release occur in various cell types and are involved in the pathology of certain forms of cardiac arrhythmia. These arrhythmias include catecholaminergic polymorphic ventricular tachycardia (CPVT), certain cases of which are associated with mutations in the cardiac calsequestrin gene (CASQ2). To explore the mechanisms of Ca2+ wave generation and unravel the underlying causes of CPVT, we investigated the effects of adenoviral-mediated changes in CASQ2 protein levels on the properties of cytosolic and sarcoplasmic reticulum (SR) Ca2+ waves in permeabilized rat ventricular myocytes. The free [Ca2+] inside the sarcoplasmic reticulum ([Ca2+]SR) was monitored by fluo-5N entrapped into the SR, and cytosolic Ca2+ was imaged using fluo-3. Overexpression of CASQ2 resulted in significant increases in the amplitude of Ca2+ waves and interwave intervals, whereas reduced CASQ2 levels caused drastic reductions in the amplitude and period of Ca2+ waves. CASQ2 abundance had no impact on resting diastolic [Ca2+]SR or on the amplitude of the [Ca2+]SR depletion signal during the Ca2+ wave. However, the recovery dynamics of [Ca2+]SR following Ca2+ release were dramatically altered as the rate of [Ca2+]SR recovery increased ∼3-fold in CASQ2-overexpressing myocytes and decreased to 30% of control in CASQ2-underexpressing myocytes. There was a direct linear relationship between Ca2+ wave period and the half-time of basal [Ca2+]SR recovery following Ca2+ release. Loading the SR with the low affinity exogenous Ca2+ buffer citrate exerted effects quantitatively similar to those observed on overexpressing CASQ2. We conclude that free intra-SR [Ca2+] is a critical determinant of cardiac Ca2+ wave generation. Our data indicate that reduced intra-SR Ca2+ binding activity promotes the generation of Ca2+ waves by accelerating the dynamics of attaining a threshold free [Ca2+]SR required for Ca2+ wave initiation, potentially accounting for arrythmogenesis in CPVT linked to mutations in CASQ2. PMID:15486014

  3. T-wave alternans negative coronary patients with low ejection and benefit from defibrillator implantation

    NASA Technical Reports Server (NTRS)

    Hohnloser, S. H.; Ikeda, T.; Bloomfield, D. M.; Dabbous, O. H.; Cohen, R. J.

    2003-01-01

    In a trial of prophylactic implantation of a defibrillator, a mortality benefit was seen among patients with previous myocardial infarction and a left-ventricular ejection fraction of 0.30 or less. We identified 129 similar patients from two previously published clinical trials in which microvolt T-wave alternans testing was prospectively assessed. At 24 months of follow-up, no sudden cardiac death or cardiac arrest was seen among patients who tested T-wave alternans negative, compared with an event rate of 15.6% among the remaining patients. Testing of T-wave alternans seems to identify patients who are at low risk of ventricular tachyarrhythmic event and who may not benefit from defibrillator therapy.

  4. Pulse wave velocity in patients with severe head injury a pilot study.

    PubMed

    Shahsavari, S; McKelvey, T; Rydenhag, B; Ritzén, C Eriksson

    2010-01-01

    The study aimed to determine the potential of pulse wave velocity measurements to reflect changes in compliant cerebral arteries/arterioles in head injured patients. The approach utilizes the electrocardiogram and intracranial pressure signals to measure the wave transit time between heart and cranial cavity. Thirty five clinical records of nineteen head injured patients, with different levels of cerebrovascular pressure-reactivity response, were investigated through the study. Results were compared with magnitude of normalized transfer function at the fundamental cardiac frequency. In patients with intact cerebrovascular pressure-reactivity, magnitude of normalized transfer function at the fundamental cardiac component was found to be highly correlated with pulse wave transit time.

  5. Implanted near-infrared spectroscopy for cardiac monitoring

    NASA Astrophysics Data System (ADS)

    Bhunia, Sourav K.; Cinbis, Can

    2011-02-01

    Implanted Cardioverter Defibrillator (ICD) provides one of the most effective therapies for the prevention of sudden cardiac death, but also delivers some high voltage shocks inappropriately, causing morbidity and mortality. Implanted near-infrared spectroscopy (NIRS) may augment ICD arrhythmia detection by monitoring skeletal muscle perfusion. A two-wavelength, single-distance, continuous-wave implanted NIRS has been evaluated in-vivo. A weighted difference of the changes in attenuation at two wavelengths, across the isobestic point of the hemoglobin spectra, was taken to be the microvascular oxygenation trend indicator (O2 Index). Although the exact weight depends on the local vascular distribution and their oxygen levels, the hypothesis that a constant weight may be adequate for hemodynamic trending during short arrhythmic episodes, was tested. The sensor was implanted subcutaneously both on fresh tissue and inside scar tissue that formed around a pre-existing implant, in 3 animals each. Attenuations were recorded at 660 and 890 nm during normal sinus rhythm (NSR) and induced ventricular fibrillation (VF). The slope of the O2 Index over 10 seconds was computed for 7 NSR and 8 VF episodes in fresh and 13 NSR and 15 VF episodes in scar tissue pockets. The mean O2 Index slope was significantly different (p<0.0001) between NSR and VF rhythms for both the fresh and scar tissue pockets. Therefore implanted NIRS may be useful for preventing inappropriate detection of VF during electromagnetic interference, double counting of ECG T-wave as an R-wave, ICD lead failure, electrocardiographic aberrancy etc.

  6. Electrocardiographic consequences of cardiac iron overload in thalassemia major

    PubMed Central

    Detterich, Jon; Noetzli, Leila; Dorey, Fred; Bar-Cohen, Yaniv; Harmatz, Paul; Coates, Thomas; Wood, John

    2011-01-01

    Background Iron cardiomyopathy is a leading cause of death in transfusion dependent thalassemia major (TM) patients and MRI (T2*) can recognize preclinical cardiac iron overload, but, is unavailable to many centers. Design and Methods We evaluated the ability of 12-lead electrocardiography to predict cardiac iron loading in TM. 12-lead electrocardiogram and cardiac T2* measurements were performed prospectively, with a detectable cardiac iron cutoff of T2*less than 20 ms. Patients with and without cardiac iron were compared using two-sample statistics and against population norms using age and gender-matched Z-scores. Results 45/78 patients had detectable cardiac iron. Patients having cardiac iron were older and more likely female but had comparable liver iron burdens and serum ferritin. Increased heart rate (HR) and prolonged corrected QT interval (QTc) were present, regardless of cardiac iron status. Repolarization abnormalities were the strongest predictors of cardiac iron, including QT/QTc prolongation, left shift of T-wave axis, and interpretation of ST/T-wave morphology. Recursive partitioning of the data for females using T-axis and HR and for males using QT, HR and T-axis produced algorithms with AUROC’s of 88.3 and 87.1 respectively. Conclusions Bradycardia and repolarization abnormalities on 12-lead electrocardiography were the most specific markers for cardiac iron in thalassemia major. Changes in these variables may be helpful to stratify cardiac risk when cardiac MRI is unavailable. However, diagnostic algorithms need to be vetted on larger and more diverse patient populations and longitudinal studies are necessary to determine reversibility of the observed abnormalities. PMID:22052662

  7. Intrapericardial denervation - Radial artery blood flow and heart rate responses to LBNP

    NASA Technical Reports Server (NTRS)

    Mckeever, Kenneth H.; Skidmore, Michael G.; Keil, Lanny C.; Sandler, Harold

    1990-01-01

    The effects of intrapericardial denervation on the radial artery blood flow velocity (RABFV) and heart rate (HR) responses to LBNP in rhesus monkeys were investigated by measuring the RABFV transcutaneously by a continuous-wave Doppler ultrasonic flowmeter in order to derive an index of forearm blood flow response to low (0 to -20 mm Hg) and high (0 to -60 mm Hg) ramp exposures during supine LBNP. Four of the eight subjects were subjected to efferent and afferent cardiac denervation. It was found that, during low levels of LBNP, monkeys with cardiac denervation exhibited no cardiopulmonary baroreceptor-mediated change in the RABFV or HR, unlike the intact animals, which showed steady decreases in RABFV during both high- and low-pressure protocols. It is suggested that forearm blood flow and HR responses to low-level LBNP, along with pharmacological challenge, are viable physiological tests for verifying the completeness of atrial and cardiopulmonary baroreceptor denervation.

  8. Local heterogeneities in cardiac systems suppress turbulence by generating multi-armed rotors

    NASA Astrophysics Data System (ADS)

    Zhang, Zhihui; Steinbock, Oliver

    2016-05-01

    Ventricular fibrillation is an extremely dangerous cardiac arrhythmia that is linked to rotating waves of electric activity and chaotically moving vortex lines. These filaments can pin to insulating, cylindrical heterogeneities which swiftly become the new rotation backbone of the local wave field. For thin cylinders, the stabilized rotation is sufficiently fast to repel the free segments of the turbulent filament tangle and annihilate them at the system boundaries. The resulting global wave pattern is periodic and highly ordered. Our cardiac simulations show that also thicker cylinders can establish analogous forms of tachycardia. This process occurs through the spontaneous formation of pinned multi-armed vortices. The observed number of wave arms N depends on the cylinder radius and is associated to stability windows that for N = 2, 3 partially overlap. For N = 1, 2, we find a small gap in which the turbulence is removed but the pinned rotor shows complex temporal dynamics. The relevance of our findings to human cardiology are discussed in the context of vortex pinning to more complex-shaped anatomical features and remodeled myocardium.

  9. Cardiac Repolarization Instability during Psychological Stress in Patients with Ventricular Arrhythmias

    PubMed Central

    Abisse, Saddam S.; Lampert, Rachel; Burg, Mattew; Soufer, Robert; Shusterman, Vladimir

    2011-01-01

    Introduction Changes in the autonomic nervous system activity (ANS) are a major trigger of life-threatening ventricular tachyarrhythmias (VTA). Mental arithmetic, a condition administered in a laboratory setting, can provide insight into the ANS effects on cardiac physiology. We examined the responses of cardiac repolarization to laboratory-induced psychological stressors in patients with implantable cardioverter defibrillators (ICDs) with the objective of identifying the indices that differentiate patients with and without subsequent VTA in follow-up. Methods Continuous ECG signals were recorded using 3 standard bipolar (Holter) leads in 56 patients (age: 63.6±11.9, female: 12%, LVEF: 32.3±11) with ICDs during mental arithmetic. The patients were separated into those with subsequent VTA during 3–4 years of follow-up (Group 1: N=9 pts) and those without VTA (Group 2: N=47 pts). Changes in repolarization (QT-interval, mean T-wave amplitude (Tamp), and T-wave area (Tarea) were analyzed during 5min of baseline, stress and recovery. The temporal instability of Tamp and Tarea was examined using the range (Δ) and variance (σ2) of beat-to-beat variations of the corresponding parameters. Results There were no significant differences in HR between the two groups at baseline (61 vs. 63 bpm, p=0.97), during stress (64 vs. 65 bpm, p=0.40), and recovery (62 vs. 61 bpm, p= 0.88). However, during mental stress and post-stress recovery ΔTamp was almost 2-fold greater in Group 1 compared with Group 2 (111 (57–203)) vs. 68 (44–94) μV p=0.04, respectively). Changes in QT-intervals were also greater in Group 1 compared with Group 2 (p=0.02). Conclusion Among patients with ICDs, changes of T-wave amplitude after psychological stress were greater in those with subsequent arrhythmic events. This might signal proarrhythmic repolarization response and help identify patients who would benefit the most from ICD implantation and proactive management. PMID:21920534

  10. Six-Year Outcome of Subjects Without Overt Heart Disease With an Early Repolarization/J Wave Electrocardiographic Pattern.

    PubMed

    Lanza, Gaetano Antonio; Argirò, Alessia; Mollo, Roberto; De Vita, Antonio; Spera, Francesco; Golino, Michele; Rota, Elisabetta; Filice, Monica; Crea, Filippo

    2017-12-01

    "Early repolarization" (ER) is a frequent finding at standard electrocardiogram (ECG). In this study we assessed whether ER is associated with an increased risk of events, as recently suggested by some studies. We prospectively enrolled 4,176 consecutive subjects without any heart disease who underwent routine ECG recording. ER was diagnosed in case of typical concave ST-segment elevation ≥0.1 mV; a J wave was diagnosed when the QRS showed a notch or a slur in its terminal part. In this study we compared the 6-year outcome of all 687 subjects with ER/J wave and 687 matched subjects without ER/J wave (controls). Both groups included 335 males and 352 females, and age was 48.8 ± 18 years. Overall, 145 deaths occurred (11%), only 11 of which attributed to cardiac causes. No sudden death was reported. Cardiac deaths occurred in 5 (0.8%) and 6 (0.9%) ER/J wave subjects and controls, respectively (odds ratio [OR] 0.85, 95% confidence interval [CI] 0.26 to 2.80, p = 0.79). Both ER (OR 1.68, 95% CI 0.21 to 13.3, p = 0.62) and J wave (OR 0.91, 95% CI 0.28 to 3.00, p = 0.88) showed no association with cardiac death. Total mortality was 11.5% in the ER/J wave group and 10.6% in the control group (OR 1.10, 95% CI 0.78 to 1.56, p = 0.58). Both ER (OR 0.44, 95% CI 0.16 to 1.24, p = 0.12) and J wave (OR 1.20, 95% CI 0.85 to 1.70, p = 0.30) showed also no association with all-cause death. In subjects without any evidence of heart disease, we found no significant association of ER/J wave with the risk of cardiac, as well as all-cause, death at medium-term follow-up. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Evolution of Spiral and Scroll Waves of Excitation in a Mathematical Model of Ischaemic Border Zone

    PubMed Central

    Biktashev, Vadim N.; Biktasheva, Irina V.; Sarvazyan, Narine A.

    2011-01-01

    Abnormal electrical activity from the boundaries of ischemic cardiac tissue is recognized as one of the major causes in generation of ischemia-reperfusion arrhythmias. Here we present theoretical analysis of the waves of electrical activity that can rise on the boundary of cardiac cell network upon its recovery from ischaemia-like conditions. The main factors included in our analysis are macroscopic gradients of the cell-to-cell coupling and cell excitability and microscopic heterogeneity of individual cells. The interplay between these factors allows one to explain how spirals form, drift together with the moving boundary, get transiently pinned to local inhomogeneities, and finally penetrate into the bulk of the well-coupled tissue where they reach macroscopic scale. The asymptotic theory of the drift of spiral and scroll waves based on response functions provides explanation of the drifts involved in this mechanism, with the exception of effects due to the discreteness of cardiac tissue. In particular, this asymptotic theory allows an extrapolation of 2D events into 3D, which has shown that cells within the border zone can give rise to 3D analogues of spirals, the scroll waves. When and if such scroll waves escape into a better coupled tissue, they are likely to collapse due to the positive filament tension. However, our simulations have shown that such collapse of newly generated scrolls is not inevitable and that under certain conditions filament tension becomes negative, leading to scroll filaments to expand and multiply leading to a fibrillation-like state within small areas of cardiac tissue. PMID:21935402

  12. A Study of Early Afterdepolarizations in a Model for Human Ventricular Tissue

    PubMed Central

    Vandersickel, Nele; Kazbanov, Ivan V.; Nuitermans, Anita; Weise, Louis D.; Pandit, Rahul; Panfilov, Alexander V.

    2014-01-01

    Sudden cardiac death is often caused by cardiac arrhythmias. Recently, special attention has been given to a certain arrhythmogenic condition, the long-QT syndrome, which occurs as a result of genetic mutations or drug toxicity. The underlying mechanisms of arrhythmias, caused by the long-QT syndrome, are not fully understood. However, arrhythmias are often connected to special excitations of cardiac cells, called early afterdepolarizations (EADs), which are depolarizations during the repolarizing phase of the action potential. So far, EADs have been studied mainly in isolated cardiac cells. However, the question on how EADs at the single-cell level can result in fibrillation at the tissue level, especially in human cell models, has not been widely studied yet. In this paper, we study wave patterns that result from single-cell EAD dynamics in a mathematical model for human ventricular cardiac tissue. We induce EADs by modeling experimental conditions which have been shown to evoke EADs at a single-cell level: by an increase of L-type Ca currents and a decrease of the delayed rectifier potassium currents. We show that, at the tissue level and depending on these parameters, three types of abnormal wave patterns emerge. We classify them into two types of spiral fibrillation and one type of oscillatory dynamics. Moreover, we find that the emergent wave patterns can be driven by calcium or sodium currents and we find phase waves in the oscillatory excitation regime. From our simulations we predict that arrhythmias caused by EADs can occur during normal wave propagation and do not require tissue heterogeneities. Experimental verification of our results is possible for experiments at the cell-culture level, where EADs can be induced by an increase of the L-type calcium conductance and by the application of I blockers, and the properties of the emergent patterns can be studied by optical mapping of the voltage and calcium. PMID:24427289

  13. Max dD/Dt: A Novel Parameter to Assess Fetal Cardiac Contractility and a Substitute for Max dP/Dt.

    PubMed

    Fujita, Yasuyuki; Kiyokoba, Ryo; Yumoto, Yasuo; Kato, Kiyoko

    2018-07-01

    Aortic pulse waveforms are composed of a forward wave from the heart and a reflection wave from the periphery. We focused on this forward wave and suggested a new parameter, the maximum slope of aortic pulse waveforms (max dD/dt), for fetal cardiac contractility. Max dD/dt was calculated from fetal aortic pulse waveforms recorded with an echo-tracking system. A normal range of max dD/dt was constructed in 105 healthy fetuses using linear regression analysis. Twenty-two fetuses with suspected fetal cardiac dysfunction were divided into normal and decreased max dD/dt groups, and their clinical parameters were compared. Max dD/dt of aortic pulse waveforms increased linearly with advancing gestational age (r = 0.93). The decreased max dD/dt was associated with abnormal cardiotocography findings and short- and long-term prognosis. In conclusion, max dD/dt calculated from the aortic pulse waveforms in fetuses can substitute for max dP/dt, an index of cardiac contractility in adults. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  14. Ryanodine receptor gating controls generation of diastolic calcium waves in cardiac myocytes

    PubMed Central

    Petrovič, Pavol; Valent, Ivan; Cocherová, Elena; Pavelková, Jana

    2015-01-01

    The role of cardiac ryanodine receptor (RyR) gating in the initiation and propagation of calcium waves was investigated using a mathematical model comprising a stochastic description of RyR gating and a deterministic description of calcium diffusion and sequestration. We used a one-dimensional array of equidistantly spaced RyR clusters, representing the confocal scanning line, to simulate the formation of calcium sparks. Our model provided an excellent description of the calcium dependence of the frequency of diastolic calcium sparks and of the increased tendency for the production of calcium waves after a decrease in cytosolic calcium buffering. We developed a hypothesis relating changes in the propensity to form calcium waves to changes of RyR gating and tested it by simulation. With a realistic RyR gating model, increased ability of RyR to be activated by Ca2+ strongly increased the propensity for generation of calcium waves at low (0.05–0.1-µM) calcium concentrations but only slightly at high (0.2–0.4-µM) calcium concentrations. Changes in RyR gating altered calcium wave formation by changing the calcium sensitivity of spontaneous calcium spark activation and/or the average number of open RyRs in spontaneous calcium sparks. Gating changes that did not affect RyR activation by Ca2+ had only a weak effect on the propensity to form calcium waves, even if they strongly increased calcium spark frequency. Calcium waves induced by modulating the properties of the RyR activation site could be suppressed by inhibiting the spontaneous opening of the RyR. These data can explain the increased tendency for production of calcium waves under conditions when RyR gating is altered in cardiac diseases. PMID:26009544

  15. Pulmonary arterial stiffening in COPD and its implications for right ventricular remodelling.

    PubMed

    Weir-McCall, Jonathan R; Liu-Shiu-Cheong, Patrick Sk; Struthers, Allan D; Lipworth, Brian J; Houston, J Graeme

    2018-02-27

    Pulmonary pulse wave velocity (PWV) allows the non-invasive measurement of pulmonary arterial stiffening, but has not previously been assessed in COPD. The aim of the current study was to assess PWV in COPD and its association with right ventricular (RV) remodelling. Fifty-eight participants with COPD underwent pulmonary function tests, 6-min walk test and cardiac MRI, while 21 healthy controls (HCs) underwent cardiac MRI. Thirty-two COPD patients underwent a follow-up MRI to assess for longitudinal changes in RV metrics. Cardiac MRI was used to quantify RV mass, volumes and PWV. Differences in continuous variables between the COPD and HC groups was tested using an independent t-test, and associations between PWV and right ventricular parameters was examined using Pearson's correlation coefficient. Those with COPD had reduced pulsatility (COPD (mean±SD):24.88±8.84% vs. HC:30.55±11.28%, p=0.021), pulmonary acceleration time (COPD:104.0±22.9ms vs. HC: 128.1±32.2ms, p<0.001), higher PWV (COPD:2.62±1.29ms -1 vs. HC:1.78±0.72ms -1 , p=0.001), lower RV end diastolic volume (COPD:53.6±11.1ml vs. HC:59.9±13.0ml, p=0.037) and RV stroke volume (COPD:31.9±6.9ml/m 2 vs. HC:37.1±6.2ml/m 2 , p=0.003) with no difference in mass (p=0.53). PWV was not associated with right ventricular parameters. While pulmonary vascular remodelling is present in COPD, cardiac remodelling favours reduced filling rather than increased afterload. Treatment of obstructive lung disease may have greater effect on cardiac function than treatment of pulmonary vascular disease in most COPD patients KEY POINTS: • Pulmonary pulse wave velocity (PWV) is elevated in COPD. • Pulmonary PWV is not associated with right ventricular remodelling. • Right ventricular remodelling is more in keeping with that of reduced filling.

  16. Using left-ventricular-only pacing to eliminate T-wave oversensing in a biventricular implantable cardiac defibrillator.

    PubMed

    Khoo, Clarence; Bennett, Matthew; Chakrabarti, Santabhanu; LeMaitre, John; Tung, Stanley K K

    2013-02-01

    A man aged 75 years and with nonischemic cardiomyopathy had implantation of a biventricular implantable cardiac defibrillator (ICD). Consistent biventricular pacing was limited by intermittent T-wave oversensing (TWOS). A strategy of left-ventricular-only pacing was used to eliminate TWOS. This strategy obviates the need to reduce ventricular sensitivity and thus may be an effective alternative to biventricular pacing complicated by TWOS. Copyright © 2013 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  17. T-wave alternans and beat-to-beat variability of repolarization: pathophysiological backgrounds and clinical relevance.

    PubMed

    Floré, Vincent; Willems, Rik

    2012-12-01

    In this review, we focus on temporal variability of cardiac repolarization. This phenomenon has been related to a higher risk for ventricular arrhythmia and is therefore interesting as a marker of sudden cardiac death risk. We review two non-invasive clinical techniques quantifying repolarization variability: T-wave alternans (TWA) and beat-to-beat variability of repolarization (BVR). We discuss their pathophysiological link with ventricular arrhythmia and the current clinical relevance of these techniques.

  18. Scaling properties of conduction velocity in heterogeneous excitable media

    NASA Astrophysics Data System (ADS)

    Shajahan, T. K.; Borek, Bartłomiej; Shrier, Alvin; Glass, Leon

    2011-10-01

    Waves of excitation through excitable media, such as cardiac tissue, can propagate as plane waves or break up to form reentrant spiral waves. In diseased hearts reentrant waves can be associated with fatal cardiac arrhythmias. In this paper we investigate the conditions that lead to wave break, reentry, and propagation failure in mathematical models of heterogeneous excitable media. Two types of heterogeneities are considered: sinks are regions in space in which the voltage is fixed at its rest value, and breaks are nonconducting regions with no-flux boundary conditions. We find that randomly distributed heterogeneities in the medium have a decremental effect on the velocity, and above a critical density of such heterogeneities the conduction fails. Using numerical and analytical methods we derive the general relationship among the conduction velocity, density of heterogeneities, diffusion coefficient, and the rise time of the excitation in both two and three dimensions. This work helps us understand the factors leading to reduced propagation velocity and the formation of spiral waves in heterogeneous excitable media.

  19. Rate-Related Left Bundle Branch Block and Cardiac Memory in a Patient with Bradycardia: Case Report and Literature Review.

    PubMed

    Seibolt, Luke; Maestas, Camila; Lazkani, Mohamad; Fatima, Umaima; Loli, Akil; Chesser, Michael

    2018-06-19

    Rate-related left bundle branch block (LBBB) is a well-studied phenomenon. Cardiac memory is another physiologic phenomenon in which T-wave abnormalities occur in the absence of ischemia. The association between these two phenomena has been described in several case reports. A literature review was performed through OVID and Pubmed, where at total of 93 cases of rate- related LBBB were identified. Cases were reviewed and data were collected on rates of appearance and disappearance as well as the presence or absence of cardiac memory. There is some overlap in the rate at which LBBB appear. Cardiac memory is associated with rate-related LBBB in several cases but its true prevalence is unknown. Cardiac memory is a phenomenon that is well described in the literature but is often under-recognized in clinical practice. As a consequence of overlooking this phenomenon and not including cardiac memory in the differential when T-wave abnormalities are observed, patients may be subjected to unnecessary invasive diagnostic testing. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  20. Aging-related arterial-cardiac interaction in Japanese men.

    PubMed

    Maruyama, Yoshiaki

    2009-11-01

    Vascular and cardiac aging is rapidly progressing among the Japanese population. A close relation exists between the artery and cardiac performance (arterial-cardiac interaction), but the relationships between age and these parameters have not been well examined. The aim of this study was to elucidate the changes of arterial-cardiac interaction with aging, using pulse wave velocity (PWV) as an indicator of atherosclerosis. The subjects comprised 595 adult men (mean age, 58.8 +/- 12.2 years) without any history of cardiovascular disease. After correlating PWV, cardiac structure, cardiac function, and blood pressure to age, subjects were divided into five age groups to compare changes in these parameters. Pulse wave velocity exhibited a strong positive correlation with age (r = 0.461, P < 0.01) and increased significantly over 55 years old, and left atrial dimension, relative wall thickness, systolic blood pressure, and pulse pressure correlated positively with age and increased similarly. Left ventricular volume correlated negatively with age and decreased similarly. These parameters significantly correlated with PWV. Aortic diameter (AoD) positively and EA ratio (E/A) negatively exhibited a correlation with age and revealed earlier change before PWV increase. Aortic diameter increased significantly over 45 years old and stayed flat, but E/A decreased linearly from the early period. Diastolic blood pressure (DBP) increased in the early period and decreased over 75 years of age. Agerelated atherosclerotic close arterial-cardiac interaction exists between the vessels and cardiac performance, but AoD, E/A, and DBP change in early age independent of atherosclerosis.

  1. A Model for Measured Traveling Waves at End-Diastole in Human Heart Wall by Ultrasonic Imaging Method

    NASA Astrophysics Data System (ADS)

    Bekki, Naoaki; Shintani, Seine A.; Ishiwata, Shin'ichi; Kanai, Hiroshi

    2016-04-01

    We observe traveling waves, measured by the ultrasonic noninvasive imaging method, in a longitudinal beam direction from the apex to the base side on the interventricular septum (IVS) during the period from the end-diastole to the beginning of systole for a healthy human heart wall. We present a possible phenomenological model to explain part of one-dimensional cardiac behaviors for the observed traveling waves around the time of R-wave of echocardiography (ECG) in the human heart. Although the observed two-dimensional patterns of traveling waves are extremely complex and no one knows yet the exact solutions for the traveling homoclinic plane wave in the one-dimensional complex Ginzburg-Landau equation (CGLE), we numerically find that part of the one-dimensional homoclinic dynamics of the phase and amplitude patterns in the observed traveling waves is similar to that of the numerical homoclinic plane-wave solutions in the CGLE with periodic boundary condition in a certain parameter space. It is suggested that part of the cardiac dynamics of the traveling waves on the IVS can be qualitatively described by the CGLE model as a paradigm for understanding biophysical nonlinear phenomena.

  2. Early Presence of Sleep Spindles on Electroencephalography Is Associated With Good Outcome After Pediatric Cardiac Arrest.

    PubMed

    Ducharme-Crevier, Laurence; Press, Craig A; Kurz, Jonathan E; Mills, Michele G; Goldstein, Joshua L; Wainwright, Mark S

    2017-05-01

    The role of sleep architecture as a biomarker for prognostication after resuscitation from cardiac arrest in children hospitalized in an ICU remains poorly defined. We sought to investigate the association between features of normal sleep architecture in children after cardiac arrest and a favorable neurologic outcome at 6 months. Retrospective review of medical records and continuous electroencephalography monitoring. Cardiac and PICU of a tertiary children's hospital. All patients from 6 months to 18 years old resuscitated from cardiac arrest who underwent continuous electroencephalography monitoring in the first 24 hours after in- or out-of-hospital cardiac arrest from January 2010 to June 2015. None. Thirty-four patients underwent continuous electroencephalography monitoring after cardiac arrest. The median age was 6.1 years (interquartile range, 1.5-12.5 yr), 20 patients were male (59%). Most cases (n = 23, 68%) suffered from in-hospital cardiac arrest. Electroencephalography monitoring was initiated a median of 9.3 hours (5.8-14.9 hr) after return of spontaneous circulation, for a median duration of 14.3 hours (6.0-16.0 hr) within the first 24-hour period after the cardiac arrest. Five patients had normal spindles, five had abnormal spindles, and 24 patients did not have any sleep architecture. The presence of spindles was associated with a favorable neurologic outcome at 6-month postcardiac arrest (p = 0.001). Continuous electroencephalography monitoring can be used in children to assess spindles in the ICU. The presence of spindles on continuous electroencephalography monitoring in the first 24 hours after resuscitation from cardiac arrest is associated with a favorable neurologic outcome. Assessment of sleep architecture on continuous electroencephalography after cardiac arrest could improve outcome prediction.

  3. Vibration-synchronized magnetic resonance imaging for the detection of myocardial elasticity changes.

    PubMed

    Elgeti, Thomas; Tzschätzsch, Heiko; Hirsch, Sebastian; Krefting, Dagmar; Klatt, Dieter; Niendorf, Thoralf; Braun, Jürgen; Sack, Ingolf

    2012-04-01

    Vibration synchronized magnetic resonance imaging of harmonically oscillating tissue interfaces is proposed for cardiac magnetic resonance elastography. The new approach exploits cardiac triggered cine imaging synchronized with extrinsic harmonic stimulation (f = 22.83 Hz) to display oscillatory tissue deformations in magnitude images. Oscillations are analyzed by intensity threshold-based image processing to track wave amplitude variations over the cardiac cycle. In agreement to literature data, results in 10 volunteers showed that endocardial wave amplitudes during systole (0.13 ± 0.07 mm) were significantly lower than during diastole (0.34 ± 0.14 mm, P < 0.001). Wave amplitudes were found to decrease 117 ± 40 ms before myocardial contraction and to increase 75 ± 31 ms before myocardial relaxation. Vibration synchronized magnetic resonance imaging improves the temporal resolution of magnetic resonance elastography as it overcomes the use of extra motion encoding gradients, is less sensitive to susceptibility artifacts, and does not suffer from dynamic range constraints frequently encountered in phase-based magnetic resonance elastography. Copyright © 2012 Wiley Periodicals, Inc.

  4. Unpinning of rotating spiral waves in cardiac tissues by circularly polarized electric fields

    PubMed Central

    Feng, Xia; Gao, Xiang; Pan, De-Bei; Li, Bing-Wei; Zhang, Hong

    2014-01-01

    Spiral waves anchored to obstacles in cardiac tissues may cause lethal arrhythmia. To unpin these anchored spirals, comparing to high-voltage side-effect traditional therapies, wave emission from heterogeneities (WEH) induced by the uniform electric field (UEF) has provided a low-voltage alternative. Here we provide a new approach using WEH induced by the circularly polarized electric field (CPEF), which has higher success rate and larger application scope than UEF, even with a lower voltage. And we also study the distribution of the membrane potential near an obstacle induced by CPEF to analyze its mechanism of unpinning. We hope this promising approach may provide a better alternative to terminate arrhythmia. PMID:24777360

  5. Differential diagnosis of cardiovascular diseases and T-wave alternans

    NASA Astrophysics Data System (ADS)

    Ramasamy, Mouli; Varadan, Vijay K.

    2016-04-01

    T wave alternans (TWA) is the variation of the T-wave in electrocardiogram that is observed between periodic beats. TWA is one of the important precursors used to diagnose sudden cardiac death (SCD). Several clinical studies have tried to determine the significance of using TWA analysis to detect abnormalities that may lead to Ventricular Arrhythmias, as well as establish metrics to perform risk stratification for cardiovascular patients with prior cardiac episodes. The statistical significance of TWA in predicting ventricular arrhythmias has been established in patients across several diagnoses. Studies have also shown the significance of the predictive value of TWA analysis in post myocardial infarction patients, risk of SCD, congestive heart failure, ischemic cardiomyopathy, and Chagas disease.

  6. Enhancement of cardiomyogenesis in stem cells by low intensity pulsed ultrasound

    NASA Astrophysics Data System (ADS)

    Teo, Ailing; Morshedi, Amir; Wang, Jen-Chieh; Lim, Mayasari; Zhou, Yufeng

    2017-03-01

    Low intensity pulsed ultrasound (LIPUS) has been shown to enhance bone and cartilage regeneration from stem cells. Gene expression of angiotensin II type 1 (AT1) receptor can be increased in LIPUS-treated osteoblasts. The AT1 receptor is a known mechanoreceptor in cardiomyocytes. It suggests that LIPUS may enhance cardiomyogenesis via mechanotransduction by increasing AT1 expression. Murine embryonic stem cells (ESCs) were treated daily by 10-min 1MHz LIPUS at spatial-average temporal-peak acoustic intensities of 30 mW/cm2 and 300 mW/cm2 in both continuous and pulsed wave (20% duty cycle) for 10 days. Polymerase chain reaction (PCR), immunocytochemistry, and beating rate were used to evaluate the cardiac viability quantitatively. After the treatment of LIPUS, beating rate of contractile areas and cardiac gene expression, such as α- and β-myosin heavy chain, were improved. Furthermore, no deleterious effects to the development of cardiac proteins were observed. All results suggest that LIPUS stimulation has the capacity of enhancing cardiomyogenesis from embryonic stem cells. With the benefit and the ease in incorporating LIPUS into various culture platforms, LIPUS has the potential to produce cardiomyocytes for clinical use in the future.

  7. Causal Scale of Rotors in a Cardiac System

    NASA Astrophysics Data System (ADS)

    Ashikaga, Hiroshi; Prieto-Castrillo, Francisco; Kawakatsu, Mari; Dehghani, Nima

    2018-04-01

    Rotors of spiral waves are thought to be one of the potential mechanisms that maintain atrial fibrillation (AF). However, disappointing clinical outcomes of rotor mapping and ablation to eliminate AF raise a serious doubt on rotors as a macro-scale mechanism that causes the micro-scale behavior of individual cardiomyocytes to maintain spiral waves. In this study, we aimed to elucidate the causal relationship between rotors and spiral waves in a numerical model of cardiac excitation. To accomplish the aim, we described the system in a series of spatiotemporal scales by generating a renormalization group, and evaluated the causal architecture of the system by quantifying causal emergence. Causal emergence is an information-theoretic metric that quantifies emergence or reduction between micro- and macro-scale behaviors of a system by evaluating effective information at each scale. We found that the cardiac system with rotors has a spatiotemporal scale at which effective information peaks. A positive correlation between the number of rotors and causal emergence was observed only up to the scale of peak causation. We conclude that rotors are not the universal mechanism to maintain spiral waves at all spatiotemporal scales. This finding may account for the conflicting benefit of rotor ablation in clinical studies.

  8. [Myocardial perfusion imaging by digital subtraction angiography].

    PubMed

    Kadowaki, H; Ishikawa, K; Ogai, T; Katori, R

    1986-03-01

    Several methods of digital subtraction angiography (DSA) were compared to determine which could better visualize regional myocardial perfusion using coronary angiography in seven patients with myocardial infarction, two with angina pectoris and five with normal coronary arteries. Satisfactory DSA was judged to be achieved if the shape of the heart on the mask film was identical to that on the live film and if both films were exactly superimposed. To obtain an identical mask film in the shape of each live film, both films were selected from the following three phases of the cardiac cycle; at the R wave of the electrocardiogram, 100 msec before the R wave, and 200 msec before the R wave. The last two were superior for obtaining mask and live films which were similar in shape, because the cardiac motion in these phases was relatively small. Using these mask and live films, DSA was performed either with the continuous image mode (CI mode) or the time interval difference mode (TID mode). The overall perfusion of contrast medium through the artery to the vein was adequately visualized using the CI mode. Passage of contrast medium through the artery, capillary and vein was visualized at each phase using TID mode. Subtracted images were displayed and photographed, and the density of the contrast medium was adequate to display contour lines as in a relief map. Using this DSA, it was found that regional perfusion of the contrast medium was not always uniform in normal subjects, depending on the typography of the coronary artery.(ABSTRACT TRUNCATED AT 250 WORDS)

  9. Cardiac and non-cardiac causes of T-wave inversion in the precordial leads in adult subjects: A Dutch case series and review of the literature

    PubMed Central

    Said, Salah AM; Bloo, Rene; de Nooijer, Ramon; Slootweg, Andries

    2015-01-01

    AIM: To describe the electrocardiographic (ECG) phenomena characterized by T-wave inversion in the precordial leads in adults and to highlight its differential diagnosis. METHODS: A retrospective chart review of 8 adult patients who were admitted with ECG T-wave inversion in the anterior chest leads with or without prolongation of corrected QT (QTc) interval. They had different clinical conditions. Each patient underwent appropriate clinical assessment including investigation for myocardial involvement. Single and multimodality non-invasive, semi-invasive and invasive diagnostic approach were used to ascertain the diagnosis. The diagnostic assessment included biochemical investigation, cardiac and abdominal ultrasound, cerebral and chest computed tomography, nuclear medicine and coronary angiography. RESULTS: Eight adult subjects (5 females) with a mean age of 66 years (range 51 to 82) are analyzed. The etiology of T-wave inversion in the precordial leads were diverse. On admission, all patients had normal blood pressure and the ECG showed sinus rhythm. Five patients showed marked prolongation of the QTc interval. The longest QTc interval (639 ms) was found in the patient with pheochromocytoma. Giant T-wave inversion (≥ 10 mm) was found in pheochromocytoma followed by electroconvulsive therapy and finally ischemic heart disease. The deepest T-wave was measured in lead V3 (5 ×). In 3 patients presented with mild T-wave inversion (patients 1, 5 and 4 mm), the QTc interval was not prolonged (432, 409 and 424 msec), respectively. CONCLUSION: T-wave inversion associated with or without QTc prolongation requires meticulous history taking, physical examination and tailored diagnostic modalities to reach rapid and correct diagnosis to establish appropriate therapeutic intervention. PMID:25717356

  10. Novel wave intensity analysis of arterial pulse wave propagation accounting for peripheral reflections

    PubMed Central

    Alastruey, Jordi; Hunt, Anthony A E; Weinberg, Peter D

    2014-01-01

    We present a novel analysis of arterial pulse wave propagation that combines traditional wave intensity analysis with identification of Windkessel pressures to account for the effect on the pressure waveform of peripheral wave reflections. Using haemodynamic data measured in vivo in the rabbit or generated numerically in models of human compliant vessels, we show that traditional wave intensity analysis identifies the timing, direction and magnitude of the predominant waves that shape aortic pressure and flow waveforms in systole, but fails to identify the effect of peripheral reflections. These reflections persist for several cardiac cycles and make up most of the pressure waveform, especially in diastole and early systole. Ignoring peripheral reflections leads to an erroneous indication of a reflection-free period in early systole and additional error in the estimates of (i) pulse wave velocity at the ascending aorta given by the PU–loop method (9.5% error) and (ii) transit time to a dominant reflection site calculated from the wave intensity profile (27% error). These errors decreased to 1.3% and 10%, respectively, when accounting for peripheral reflections. Using our new analysis, we investigate the effect of vessel compliance and peripheral resistance on wave intensity, peripheral reflections and reflections originating in previous cardiac cycles. PMID:24132888

  11. Assessment of mitral regurgitation in dogs: comparison of results of echocardiography with magnetic resonance imaging.

    PubMed

    Sargent, J; Connolly, D J; Watts, V; Mõtsküla, P; Volk, H A; Lamb, C R; Fuentes, V Luis

    2015-11-01

    Echocardiography is used routinely to assess mitral regurgitation severity, but echocardiographic measures of mitral regurgitation in dogs have not been compared with other quantitative methods. The study aim was to compare echocardiographic measures of mitral regurgitation with cardiac magnetic resonance imaging-derived mitral regurgitant fraction in small-breed dogs. Dogs with myxomatous mitral valve disease scheduled for magnetic resonance imaging assessment of neurological disease were recruited. Correlations were tested between cardiac magnetic resonance imaging-derived mitral regurgitant fraction and the following echocardiographic measures: vena contracta/aortic diameter, transmitral E-wave velocity, amplitude of mitral prolapse/aortic diameter, diastolic left ventricular diameter:aortic diameter, left atrium:aortic diameter, mitral regurgitation jet area ratio and regurgitant fraction calculated using the proximal isovelocity surface area method. Measurement of cardiac magnetic resonance imaging-derived mitral regurgitant fraction was attempted in 21 dogs. Twelve consecutive, complete studies were obtained and 10 dogs were included in the final analysis: vena contracta/aortic diameter (r = 0 · 89, p = 0 · 001) and E-wave velocity (r = 0 · 86, p = 0 · 001) had the strongest correlations with cardiac magnetic resonance imaging-derived mitral regurgitant fraction. E velocity had superior repeatability and could be measured in all dogs. The presence of multiple jets precluded vena contracta/aortic diameter measurement in one dog. Measurement of cardiac magnetic resonance imaging-derived mitral regurgitant fraction is feasible but technically demanding. The echocardiographic measures that correlated most closely with cardiac magnetic resonance imaging-derived mitral regurgitant fraction were vena contracta/aortic diameter and E-wave velocity. © 2015 British Small Animal Veterinary Association.

  12. Electrocardiogram changes and atrial arrhythmias in individuals carrying sodium channel SCN5A D1275N mutation.

    PubMed

    Vanninen, Sari U M; Nikus, Kjell; Aalto-Setälä, Katriina

    2017-09-01

    The cardiac sodium channel SCN5A regulates atrioventricular and ventricular depolarization as well as cardiac conduction. Patients with cardiac electrical abnormalities have an increased risk of sudden cardiac death (SCD) and cardio-embolic stroke. Optimal management of cardiac disease includes the understanding of association between the causative mutations and the clinical phenotype. A 12-lead electrocardiogram (ECG) is an easy and inexpensive tool for finding risk patients. A blood sample for DNA extraction was obtained in a Finnish family with 43 members; systematic 12-lead ECG analysis was performed in 13 of the family members carrying an SCN5A D1275N mutation. Conduction defects and supraventricular arrhythmias, including atrial fibrillation/flutter, atrioventricular nodal re-entry tachycardia (AVNRT) and junctional rhythm were searched for. Five (38%) mutation carriers had fascicular or bundle branch block, 10 had atrial arrhythmias; no ventricular arrhythmias were found. Notching of the R- and S waves - including initial QRS fragmentation - and prolonged S-wave upstroke were present in all the affected family members. Notably, four (31%) affected family members had a stroke before the age of 31 and two experienced premature death. A 12-lead ECG can be used to predict arrhythmias in SCN5A D1275N mutation carriers. Key messages The 12-lead ECG may reveal cardiac abnormalities even before clinical symptoms occur. Specific ECG findings - initial QRS fragmentation, prolonged S-wave upstroke as well as supraventricular arrhythmias - were frequently encountered in all SCN5A D1257N mutation carriers. ECG follow-up is recommended for all SCN5A D1275N mutation carriers.

  13. Complexity of cardiac signals for predicting changes in alpha-waves after stress in patients undergoing cardiac catheterization

    NASA Astrophysics Data System (ADS)

    Chiu, Hung-Chih; Lin, Yen-Hung; Lo, Men-Tzung; Tang, Sung-Chun; Wang, Tzung-Dau; Lu, Hung-Chun; Ho, Yi-Lwun; Ma, Hsi-Pin; Peng, Chung-Kang

    2015-08-01

    The hierarchical interaction between electrical signals of the brain and heart is not fully understood. We hypothesized that the complexity of cardiac electrical activity can be used to predict changes in encephalic electricity after stress. Most methods for analyzing the interaction between the heart rate variability (HRV) and electroencephalography (EEG) require a computation-intensive mathematical model. To overcome these limitations and increase the predictive accuracy of human relaxing states, we developed a method to test our hypothesis. In addition to routine linear analysis, multiscale entropy and detrended fluctuation analysis of the HRV were used to quantify nonstationary and nonlinear dynamic changes in the heart rate time series. Short-time Fourier transform was applied to quantify the power of EEG. The clinical, HRV, and EEG parameters of postcatheterization EEG alpha waves were analyzed using change-score analysis and generalized additive models. In conclusion, the complexity of cardiac electrical signals can be used to predict EEG changes after stress.

  14. Complexity of cardiac signals for predicting changes in alpha-waves after stress in patients undergoing cardiac catheterization

    PubMed Central

    Chiu, Hung-Chih; Lin, Yen-Hung; Lo, Men-Tzung; Tang, Sung-Chun; Wang, Tzung-Dau; Lu, Hung-Chun; Ho, Yi-Lwun; Ma, Hsi-Pin; Peng, Chung-Kang

    2015-01-01

    The hierarchical interaction between electrical signals of the brain and heart is not fully understood. We hypothesized that the complexity of cardiac electrical activity can be used to predict changes in encephalic electricity after stress. Most methods for analyzing the interaction between the heart rate variability (HRV) and electroencephalography (EEG) require a computation-intensive mathematical model. To overcome these limitations and increase the predictive accuracy of human relaxing states, we developed a method to test our hypothesis. In addition to routine linear analysis, multiscale entropy and detrended fluctuation analysis of the HRV were used to quantify nonstationary and nonlinear dynamic changes in the heart rate time series. Short-time Fourier transform was applied to quantify the power of EEG. The clinical, HRV, and EEG parameters of postcatheterization EEG alpha waves were analyzed using change-score analysis and generalized additive models. In conclusion, the complexity of cardiac electrical signals can be used to predict EEG changes after stress. PMID:26286628

  15. Quantification of instantaneous flow rate and dynamically changing effective orifice area using a geometry independent three-dimensional digital color Doppler method: An in vitro study mimicking mitral regurgitation.

    PubMed

    Li, Xiaokui; Wanitkun, Suthep; Li, Xiang-Ning; Hashimoto, Ikuo; Mori, Yoshiki; Rusk, Rosemary A; Hicks, Shannon E; Sahn, David J

    2002-10-01

    Our study was intended to test the accuracy of a 3-dimensional (3D) digital color Doppler flow convergence (FC) method for assessing the effective orifice area (EOA) in a new dynamic orifice model mimicking a variety of mitral regurgitation. FC surface area methods for detecting EOA have been reported to be useful for quantifying the severity of valvular regurgitation. With our new 3D digital direct FC method, all raw velocity data are available and variable Nyquist limits can be selected for computation of direct FC surface area for computing instantaneous flow rate and temporal change of EOA. A 7.0-MHz multiplane transesophageal probe from an ultrasound system (ATL HDI 5000) was linked and controlled by a computer workstation to provide 3D images. Three differently shaped latex orifices (zigzag, arc, and straight slit, each with cutting-edge length of 1 cm) were used to mimic the dynamic orifice of mitral regurgitation. 3D FC surface computation was performed on parallel slices through the 3D data set at aliasing velocities (14-48 cm/s) selected to maximize the regularity and minimize lateral dropout of the visualized 3D FC at 5 points per cardiac cycle. Using continuous wave velocity for each, 3D-calculated EOA was compared with EOA determined by using continuous wave Doppler and the flow rate from a reference ultrasonic flow meter. Simultaneous digital video images were also recorded to define the actual orifice size for 9 stroke volumes (15-55 mL/beat with maximum flow rates 45-182 mL/s). Over the 9 pulsatile flow states and 3 orifices, 3D FC EOAs (0.05-0.63 cm(2)) from different phases of the cardiac cycle in each pump setting correlated well with reference EOA (r = 0.89-0.92, SEE = 0.027-0.055cm(2)) and they also correlated well with digital video images of the actual orifice peak (r = 0.97-0.98, SEE = 0.016-0.019 cm(2)), although they were consistently smaller, as expected by the contraction coefficient. The digital 3D FC method can accurately predict flow rate, and, thus, EOA (in conjunction with continuous wave Doppler), because it allows direct FC surface measurement despite temporal variability of FC shape.

  16. Pulsed Phase Lock Loop Device for Monitoring Intracranial Pressure During Space Flight

    NASA Technical Reports Server (NTRS)

    Ueno, Toshiaki; Macias, Brandon R.; Yost, William T.; Hargens, Alan R.

    2003-01-01

    We have developed an ultrasonic device to monitor ICP waveforms non-invasively from cranial diameter oscillations using a NASA-developed pulsed phase lock loop (PPLL) technique. The purpose of this study was to attempt to validate the PPLL device for reliable recordings of ICP waveforms and analysis of ICP dynamics in vivo. METHODS: PPLL outputs were recorded in patients during invasive ICP monitoring at UCSD Medical Center (n=10). RESULTS: An averaged linear regression coefficient between ICP and PPLL waveform data during one cardiac cycle in all patients is 0.88 +/- 0.02 (mean +/- SE). Coherence function analysis indicated that ICP and PPLL waveforms have high correlation in the lst, 2nd, and 3rd harmonic waves associated with a cardiac cycle. CONCLUSIONS: PPLL outputs represent ICP waveforms in both frequency and time domains. PPLL technology enables in vivo evaluation of ICP dynamics non-invasively, and can acquire continuous ICP waveforms during spaceflight because of compactness and non-invasive nature.

  17. The Diagnostic Value of Pulsed Wave Tissue Doppler Imaging in Asymptomatic Beta- Thalassemia Major Children and Young Adults; Relation to Chemical Biomarkers of Left Ventricular Function and Iron Overload

    PubMed Central

    Ragab, Seham M; Fathy, Waleed M; El-Aziz, Walaa FAbd; Helal, Rasha T

    2015-01-01

    Background Cardiac iron toxicity is the leading cause of death among β-halassaemia major (TM) patients. Once heart failure becomes overt, it is difficult to reverse. Objectives To investigate non-overt cardiac dysfunctions in TM patients using pulsed wave Tissue Doppler Imaging (TD I) and its relation to iron overload and brain natriuretic peptide (BNP). Methods Thorough clinical, conventional echo and pulsed wave TDI parameters were compared between asymptomatic 25 β-TM patients and 20 age and gender matched individuals. Serum ferritin and plasma BNP levels were assayed by ELISA. Results TM patients had significant higher mitral inflow early diastolic (E) wave and non significant other conventional echo parameters. In the patient group, pulsed wave TDI revealed systolic dysfunctions, in the form of significant higher isovolumetric contraction time (ICT), and lower ejection time (E T), with diastolic dysfunction in the form of higher isovolumetric relaxation time (IRT), and lower mitral annulus early diastolic velocity E′ (12.07 ±2.06 vs 15.04±2.65, P= 0.003) compared to the controls. Plasma BNP was higher in patients compared to the controls. Plasma BNP and serum ferritin had a significant correlation with each other and with pulsed wave conventional and TDI indices of systolic and diastolic functions. Patients with E/E′ ≥ 8 had significant higher serum ferritin and plasma BNP levels compared to those with ratio < 8 without a difference in Hb levels. Conclusion Pulsed wave TDI is an important diagnostic tool for latent cardiac dysfunction in iron-loaded TM patients and is related to iron overload and BNP. PMID:26401240

  18. The Diagnostic Value of Pulsed Wave Tissue Doppler Imaging in Asymptomatic Beta- Thalassemia Major Children and Young Adults; Relation to Chemical Biomarkers of Left Ventricular Function and Iron Overload.

    PubMed

    Ragab, Seham M; Fathy, Waleed M; El-Aziz, Walaa FAbd; Helal, Rasha T

    2015-01-01

    Cardiac iron toxicity is the leading cause of death among β-halassaemia major (TM) patients. Once heart failure becomes overt, it is difficult to reverse. To investigate non-overt cardiac dysfunctions in TM patients using pulsed wave Tissue Doppler Imaging (TD I) and its relation to iron overload and brain natriuretic peptide (BNP). Thorough clinical, conventional echo and pulsed wave TDI parameters were compared between asymptomatic 25 β-TM patients and 20 age and gender matched individuals. Serum ferritin and plasma BNP levels were assayed by ELISA. TM patients had significant higher mitral inflow early diastolic (E) wave and non significant other conventional echo parameters. In the patient group, pulsed wave TDI revealed systolic dysfunctions, in the form of significant higher isovolumetric contraction time (ICT), and lower ejection time (E T), with diastolic dysfunction in the form of higher isovolumetric relaxation time (IRT), and lower mitral annulus early diastolic velocity E' (12.07 ±2.06 vs 15.04±2.65, P= 0.003) compared to the controls. Plasma BNP was higher in patients compared to the controls. Plasma BNP and serum ferritin had a significant correlation with each other and with pulsed wave conventional and TDI indices of systolic and diastolic functions. Patients with E/E' ≥ 8 had significant higher serum ferritin and plasma BNP levels compared to those with ratio < 8 without a difference in Hb levels. Pulsed wave TDI is an important diagnostic tool for latent cardiac dysfunction in iron-loaded TM patients and is related to iron overload and BNP.

  19. Visualization of spiral and scroll waves in simulated and experimental cardiac tissue

    NASA Astrophysics Data System (ADS)

    Cherry, E. M.; Fenton, F. H.

    2008-12-01

    The heart is a nonlinear biological system that can exhibit complex electrical dynamics, complete with period-doubling bifurcations and spiral and scroll waves that can lead to fibrillatory states that compromise the heart's ability to contract and pump blood efficiently. Despite the importance of understanding the range of cardiac dynamics, studying how spiral and scroll waves can initiate, evolve, and be terminated is challenging because of the complicated electrophysiology and anatomy of the heart. Nevertheless, over the last two decades advances in experimental techniques have improved access to experimental data and have made it possible to visualize the electrical state of the heart in more detail than ever before. During the same time, progress in mathematical modeling and computational techniques has facilitated using simulations as a tool for investigating cardiac dynamics. In this paper, we present data from experimental and simulated cardiac tissue and discuss visualization techniques that facilitate understanding of the behavior of electrical spiral and scroll waves in the context of the heart. The paper contains many interactive media, including movies and interactive two- and three-dimensional Java appletsDisclaimer: IOP Publishing was not involved in the programming of this software and does not accept any responsibility for it. You download and run the software at your own risk. If you experience any problems with the software, please contact the author directly. To the fullest extent permitted by law, IOP Publishing Ltd accepts no responsibility for any loss, damage and/or other adverse effect on your computer system caused by your downloading and running this software. IOP Publishing Ltd accepts no responsibility for consequential loss..

  20. Mapping of Cardiac Electrical Activation with Electromechanical Wave Imaging: An in silico-in vivo Reciprocity Study

    PubMed Central

    Provost, Jean; Gurev, Viatcheslav; Trayanova, Natalia; Konofagou, Elisa E.

    2011-01-01

    Background Electromechanical Wave Imaging (EWI) is an entirely non-invasive, ultrasound-based imaging method capable of mapping the electromechanical activation sequence of the ventricles in vivo. Given the broad accessibility of ultrasound scanners in the clinic, the application of EWI could constitute a flexible surrogate for the 3D electrical activation. Objective The purpose of this report is to reproduce the electromechanical wave (EW) using an anatomically-realistic electromechanical model, and establish the capability of EWI to map the electrical activation sequence in vivo when pacing from different locations. Methods EWI was performed in one canine during pacing from three different sites. A high-resolution dynamic model of coupled cardiac electromechanics of the canine heart was used to predict the experimentally recorded electromechanical wave. The simulated 3D electrical activation sequence was then compared with the experimental EW. Results The electrical activation sequence and the EW were highly correlated for all pacing sites. The relationship between the electrical activation and the EW onset was found to be linear with a slope of 1.01 to 1.17 for different pacing schemes and imaging angles. Conclusions The accurate reproduction of the EW in simulations indicates that the model framework is capable of accurately representing the cardiac electromechanics and thus testing new hypotheses. The one-to-one correspondence between the electrical activation sequence and the EW indicates that EWI could be used to map the cardiac electrical activity. This opens the door for further exploration of the technique in assisting in the early detection, diagnosis and treatment monitoring of rhythm dysfunction. PMID:21185403

  1. Detection and Prevention of Cardiac Arrhythmias During Space Flight

    NASA Technical Reports Server (NTRS)

    Pillai, Dilip; Rosenbaum, David S.; Liszka, Kathy J.; York, David W.; Mackin, Michael A.; Lichter, Michael J.

    2004-01-01

    There have been reports suggesting that long-duration space flight might lead to an increased risk of potentially serious heart rhythm disturbances. If space flight does, in fact, significantly decrease cardiac electrical stability, the effects could be catastrophic, potentially leading to sudden cardiac death. It will be important to determine the mechanisms underlying this phenomenon in order to prepare for long-term manned lunar and interplanetary missions and to develop appropriate countermeasures. Electrical alternans affecting the ST segment and T-wave have been demonstrated to be common among patients at increased risk for ventricular arrhythmias. Subtle electrical alternans on the ECG may serve as a noninvasive marker of vulnerability to ventricular arrhythmias. We are studying indices of electrical instability in the heart for long term space missions by non-invasively measuring microvolt level T-wave alternans in a reduced gravity environment. In this investigation we are using volunteer subjects on the KC-135 aircraft as an initial study of the effect of electrical adaptation of the heart to microgravity. T-wave alternans will be analyzed for heart rate variability and QT restitution curve plotting will be compared for statistical significance.

  2. Fibroblast proliferation alters cardiac excitation conduction and contraction: a computational study.

    PubMed

    Zhan, He-qing; Xia, Ling; Shou, Guo-fa; Zang, Yun-liang; Liu, Feng; Crozier, Stuart

    2014-03-01

    In this study, the effects of cardiac fibroblast proliferation on cardiac electric excitation conduction and mechanical contraction were investigated using a proposed integrated myocardial-fibroblastic electromechanical model. At the cellular level, models of the human ventricular myocyte and fibroblast were modified to incorporate a model of cardiac mechanical contraction and cooperativity mechanisms. Cellular electromechanical coupling was realized with a calcium buffer. At the tissue level, electrical excitation conduction was coupled to an elastic mechanics model in which the finite difference method (FDM) was used to solve electrical excitation equations, and the finite element method (FEM) was used to solve mechanics equations. The electromechanical properties of the proposed integrated model were investigated in one or two dimensions under normal and ischemic pathological conditions. Fibroblast proliferation slowed wave propagation, induced a conduction block, decreased strains in the fibroblast proliferous tissue, and increased dispersions in depolarization, repolarization, and action potential duration (APD). It also distorted the wave-front, leading to the initiation and maintenance of re-entry, and resulted in a sustained contraction in the proliferous areas. This study demonstrated the important role that fibroblast proliferation plays in modulating cardiac electromechanical behaviour and which should be considered in planning future heart-modeling studies.

  3. Fibroblast proliferation alters cardiac excitation conduction and contraction: a computational study*

    PubMed Central

    Zhan, He-qing; Xia, Ling; Shou, Guo-fa; Zang, Yun-liang; Liu, Feng; Crozier, Stuart

    2014-01-01

    In this study, the effects of cardiac fibroblast proliferation on cardiac electric excitation conduction and mechanical contraction were investigated using a proposed integrated myocardial-fibroblastic electromechanical model. At the cellular level, models of the human ventricular myocyte and fibroblast were modified to incorporate a model of cardiac mechanical contraction and cooperativity mechanisms. Cellular electromechanical coupling was realized with a calcium buffer. At the tissue level, electrical excitation conduction was coupled to an elastic mechanics model in which the finite difference method (FDM) was used to solve electrical excitation equations, and the finite element method (FEM) was used to solve mechanics equations. The electromechanical properties of the proposed integrated model were investigated in one or two dimensions under normal and ischemic pathological conditions. Fibroblast proliferation slowed wave propagation, induced a conduction block, decreased strains in the fibroblast proliferous tissue, and increased dispersions in depolarization, repolarization, and action potential duration (APD). It also distorted the wave-front, leading to the initiation and maintenance of re-entry, and resulted in a sustained contraction in the proliferous areas. This study demonstrated the important role that fibroblast proliferation plays in modulating cardiac electromechanical behaviour and which should be considered in planning future heart-modeling studies. PMID:24599687

  4. Comparison of the impedance cardiogram with continuous wave radar using body-contact antennas.

    PubMed

    Buxi, Dilpreet; Dugar, Rahul; Redoute, Jean-Michel; Yuce, Mehmet Rasit

    2017-07-01

    This paper describes a continuous wave (CW) radar system with body-contact antennas and basic signal processing. The goal is to assess the signals' reproducibility across different subjects as well as a respiration cycle. Radar signals using body-contact antennas with a carrier frequency of 868 MHz are used to acquire the cardiac activity at the sternum. The radar I and Q channel signals are combined to form their magnitude. Signals are collected from six healthy males during paced breathing conditions. The electrocardiogram (ECG) and impedance cardiogram (ICG) signals are acquired simultaneously as reference. The chosen feature in the radar signal is the maximum of its second derivative, which is closest to the ICG B-point. The median and mean absolute errors in pre-ejection period (PEP) in milliseconds between the ICG's B-point and chosen feature in the radar signal range from -6-119.7 ms and 7.8-62.3 ms for all subjects. The results indicate that a reproducible radar signal is obtained from all six subjects. More work is needed on understanding the origin of the radar signals using ultrasound as a comparison.

  5. Interaction between spiral and paced waves in cardiac tissue

    PubMed Central

    Agladze, Konstantin; Kay, Matthew W.; Krinsky, Valentin; Sarvazyan, Narine

    2010-01-01

    For prevention of lethal arrhythmias, patients at risk receive implantable cardioverter-defibrillators, which use high-frequency antitachycardia pacing (ATP) to convert tachycardias to a normal rhythm. One of the suggested ATP mechanisms involves paced-induced drift of rotating waves followed by their collision with the boundary of excitable tissue. This study provides direct experimental evidence of this mechanism. In monolayers of neonatal rat cardiomyocytes in which rotating waves of activity were initiated by premature stimuli, we used the Ca2+-sensitive indicator fluo 4 to observe propagating wave patterns. The interaction of the spiral tip with a paced wave was then monitored at a high spatial resolution. In the course of the experiments, we observed spiral wave pinning to local heterogeneities within the myocyte layer. High-frequency pacing led, in a majority of cases, to successful termination of spiral activity. Our data show that 1) stable spiral waves in cardiac monolayers tend to be pinned to local heterogeneities or areas of altered conduction, 2) overdrive pacing can shift a rotating wave from its original site, and 3) the wave break, formed as a result of interaction between the spiral tip and a paced wave front, moves by a paced-induced drift mechanism to an area where it may become unstable or collide with a boundary. The data were complemented by numerical simulations, which was used to further analyze experimentally observed behavior. PMID:17384124

  6. Generalized minimal principle for rotor filaments.

    PubMed

    Dierckx, Hans; Wellner, Marcel; Bernus, Olivier; Verschelde, Henri

    2015-05-01

    To a reaction-diffusion medium with an inhomogeneous anisotropic diffusion tensor D, we add a fourth spatial dimension such that the determinant of the diffusion tensor is constant in four dimensions. We propose a generalized minimal principle for rotor filaments, stating that the scroll wave filament strives to minimize its surface area in the higher-dimensional space. As a consequence, stationary scroll wave filaments in the original 3D medium are geodesic curves with respect to the metric tensor G=det(D)D(-1). The theory is confirmed by numerical simulations for positive and negative filament tension and a model with a non-stationary spiral core. We conclude that filaments in cardiac tissue with positive tension preferentially reside or anchor in regions where cardiac cells are less interconnected, such as portions of the cardiac wall with a large number of cleavage planes.

  7. Atypical patterns of cardiac involvement in Fabry disease.

    PubMed

    Coughlan, J J; Elkholy, K; O'Brien, J; Kiernan, T

    2016-03-17

    A 58-year-old woman was referred to our cardiology service with chest pain, exertional dyspnoea and palpitations on a background of known Fabry disease diagnosed with genetic testing in 1994. ECG showed sinus rhythm, shortened PR interval, widespread t wave inversion, q waves in the lateral leads and left ventricular hypertrophy (LVH). Coronary angiogram showed only mild atheroma. Transthoracic echocardiogram showed anterolateral LVH and reduced left ventricular cavity size in keeping with Fabry cardiomyopathy. Cardiac MRI demonstrated asymmetric hypertrophy with evidence of diffuse myocardial fibrosis in the maximally hypertrophied segments from base to apex with late gadolinium enhancement in the anterior and anteroseptal walls. This was quite an atypical appearance for Fabry cardiomyopathy. This case highlights the heterogeneity of patterns of cardiac involvement that may be associated with this rare X-linked lysosomal disorder. 2016 BMJ Publishing Group Ltd.

  8. Adapting detection sensitivity based on evidence of irregular sinus arrhythmia to improve atrial fibrillation detection in insertable cardiac monitors.

    PubMed

    Pürerfellner, Helmut; Sanders, Prashanthan; Sarkar, Shantanu; Reisfeld, Erin; Reiland, Jerry; Koehler, Jodi; Pokushalov, Evgeny; Urban, Luboš; Dekker, Lukas R C

    2017-10-03

    Intermittent change in p-wave discernibility during periods of ectopy and sinus arrhythmia is a cause of inappropriate atrial fibrillation (AF) detection in insertable cardiac monitors (ICM). To address this, we developed and validated an enhanced AF detection algorithm. Atrial fibrillation detection in Reveal LINQ ICM uses patterns of incoherence in RR intervals and absence of P-wave evidence over a 2-min period. The enhanced algorithm includes P-wave evidence during RR irregularity as evidence of sinus arrhythmia or ectopy to adaptively optimize sensitivity for AF detection. The algorithm was developed and validated using Holter data from the XPECT and LINQ Usability studies which collected surface electrocardiogram (ECG) and continuous ICM ECG over a 24-48 h period. The algorithm detections were compared with Holter annotations, performed by multiple reviewers, to compute episode and duration detection performance. The validation dataset comprised of 3187 h of valid Holter and LINQ recordings from 138 patients, with true AF in 37 patients yielding 108 true AF episodes ≥2-min and 449 h of AF. The enhanced algorithm reduced inappropriately detected episodes by 49% and duration by 66% with <1% loss in true episodes or duration. The algorithm correctly identified 98.9% of total AF duration and 99.8% of total sinus or non-AF rhythm duration. The algorithm detected 97.2% (99.7% per-patient average) of all AF episodes ≥2-min, and 84.9% (95.3% per-patient average) of detected episodes involved AF. An enhancement that adapts sensitivity for AF detection reduced inappropriately detected episodes and duration with minimal reduction in sensitivity. © The Author 2017. Published by Oxford University Press on behalf of the European Society of Cardiology

  9. Detection of low-volume blood loss: compensatory reserve versus traditional vital signs.

    PubMed

    Stewart, Camille L; Mulligan, Jane; Grudic, Greg Z; Convertino, Victor A; Moulton, Steven L

    2014-12-01

    Humans are able to compensate for low-volume blood loss with minimal change in traditional vital signs. We hypothesized that a novel algorithm, which analyzes photoplethysmogram (PPG) wave forms to continuously estimate compensatory reserve would provide greater sensitivity and specificity to detect low-volume blood loss compared with traditional vital signs. The compensatory reserve index (CRI) is a measure of the reserve remaining to compensate for reduced central blood volume, where a CRI of 1 represents supine normovolemia and 0 represents the circulating blood volume at which hemodynamic decompensation occurs; values between 1 and 0 indicate the proportion of reserve remaining. Subjects underwent voluntary donation of 1 U (approximately 450 mL) of blood. Demographic and continuous noninvasive vital sign wave form data were collected, including PPG, heart rate, systolic blood pressure, cardiac output, and stroke volume. PPG wave forms were later processed by the algorithm to estimate CRI values. Data were collected from 244 healthy subjects (79 males and 165 females), with a mean (SD) age of 40.1 (14.2) years and mean (SD) body mass index of 25.6 (4.7). After blood donation, CRI significantly decreased in 92% (α = 0.05; 95% confidence interval [CI], 88-95%) of the subjects. With the use of a threshold decrease in CRI of 0.05 or greater for the detection of 1 U of blood loss, the receiver operating characteristic area under the curve was 0.90, with a sensitivity of 0.84 and specificity of 0.86. In comparison, systolic blood pressure (52%; 95% CI, 45-59%), heart rate (65%; 95% CI, 58-72%), cardiac output (47%; 95% CI, 40-54%), and stroke volume (74%; 95% CI, 67-80%) changed in fewer subjects, had significantly lower receiver operating characteristic area under the curve values, and significantly lower specificities for detecting the same volume of blood loss. Consistent with our hypothesis, CRI detected low-volume blood loss with significantly greater specificity than other traditional physiologic measures. These findings warrant further evaluation of the CRI algorithm in actual trauma settings. Diagnostic study, level II.

  10. PGC-1{alpha} accelerates cytosolic Ca{sup 2+} clearance without disturbing Ca{sup 2+} homeostasis in cardiac myocytes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Min, E-mail: chenminyx@gmail.com; Yunnan Centers for Diseases Prevention and Control, Kunming 650022; Wang, Yanru

    2010-06-11

    Energy metabolism and Ca{sup 2+} handling serve critical roles in cardiac physiology and pathophysiology. Peroxisome proliferator-activated receptor gamma coactivator 1 alpha (PGC-1{alpha}) is a multi-functional coactivator that is involved in the regulation of cardiac mitochondrial functional capacity and cellular energy metabolism. However, the regulation of PGC-1{alpha} in cardiac Ca{sup 2+} signaling has not been fully elucidated. To address this issue, we combined confocal line-scan imaging with off-line imaging processing to characterize calcium signaling in cultured adult rat ventricular myocytes expressing PGC-1{alpha} via adenoviral transduction. Our data shows that overexpressing PGC-1{alpha} improved myocyte contractility without increasing the amplitude of Ca{sup 2+}more » transients, suggesting that myofilament sensitivity to Ca{sup 2+} increased. Interestingly, the decay kinetics of global Ca{sup 2+} transients and Ca{sup 2+} waves accelerated in PGC-1{alpha}-expressing cells, but the decay rate of caffeine-elicited Ca{sup 2+} transients showed no significant change. This suggests that sarcoplasmic reticulum (SR) Ca{sup 2+}-ATPase (SERCA2a), but not Na{sup +}/Ca{sup 2+} exchange (NCX) contribute to PGC-1{alpha}-induced cytosolic Ca{sup 2+} clearance. Furthermore, PGC-1{alpha} induced the expression of SERCA2a in cultured cardiac myocytes. Importantly, overexpressing PGC-1{alpha} did not disturb cardiac Ca{sup 2+} homeostasis, because SR Ca{sup 2+} load and the propensity for Ca{sup 2+} waves remained unchanged. These data suggest that PGC-1{alpha} can ameliorate cardiac Ca{sup 2+} cycling and improve cardiac work output in response to physiological stress. Unraveling the PGC-1{alpha}-calcium handing pathway sheds new light on the role of PGC-1{alpha} in the therapy of cardiac diseases.« less

  11. Rationale and design for the Predictors of Arrhythmic and Cardiovascular Risk in End Stage Renal Disease (PACE) study.

    PubMed

    Parekh, Rulan S; Meoni, Lucy A; Jaar, Bernard G; Sozio, Stephen M; Shafi, Tariq; Tomaselli, Gordon F; Lima, Joao A; Tereshchenko, Larisa G; Estrella, Michelle M; Kao, W H Linda

    2015-04-24

    Sudden cardiac death occurs commonly in the end-stage renal disease population receiving dialysis, with 25% dying of sudden cardiac death over 5 years. Despite this high risk, surprisingly few prospective studies have studied clinical- and dialysis-related risk factors for sudden cardiac death and arrhythmic precursors of sudden cardiac death in end-stage renal disease. We present a brief summary of the risk factors for arrhythmias and sudden cardiac death in persons with end-stage renal disease as the rationale for the Predictors of Arrhythmic and Cardiovascular Risk in End Stage Renal Disease (PACE) study, a prospective cohort study of patients recently initiated on chronic hemodialysis, with the overall goal to understand arrhythmic and sudden cardiac death risk. Participants were screened for eligibility and excluded if they already had a pacemaker or an automatic implantable cardioverter defibrillator. We describe the study aims, design, and data collection of 574 incident hemodialysis participants from the Baltimore region in Maryland, U.S.A.. Participants were recruited from 27 hemodialysis units and underwent detailed clinical, dialysis and cardiovascular evaluation at baseline and follow-up. Cardiovascular phenotyping was conducted on nondialysis days with signal averaged electrocardiogram, echocardiogram, pulse wave velocity, ankle, brachial index, and cardiac computed tomography and angiography conducted at baseline. Participants were followed annually with study visits including electrocardiogram, pulse wave velocity, and ankle brachial index up to 4 years. A biorepository of serum, plasma, DNA, RNA, and nails were collected to study genetic and serologic factors associated with disease. Studies of modifiable risk factors for sudden cardiac death will help set the stage for clinical trials to test therapies to prevent sudden cardiac death in this high-risk population.

  12. Transition of spiral calcium waves between multiple stable patterns can be triggered by a single calcium spark in a fire-diffuse-fire model

    PubMed Central

    Tang, Ai-Hui; Wang, Shi-Qiang

    2009-01-01

    Spiral patterns have been found in various nonequilibrium systems. The Ca2+-induced Ca2+ release system in single cardiac cells is unique for highly discrete reaction elements, each giving rise to a Ca2+ spark upon excitation. We imaged the spiral Ca2+ waves in isolated cardiac cells and numerically studied the effect of system excitability on spiral patterns using a two-dimensional fire-diffuse-fire model. We found that under certain conditions, the system was able to display multiple stable patterns of spiral waves, each exhibiting different periods and distinct routines of spiral tips. Transition between these different patterns could be triggered by an internal fluctuation in the form of a single Ca2+ spark. PMID:19792039

  13. Unstable spiral waves and local Euclidean symmetry in a model of cardiac tissue.

    PubMed

    Marcotte, Christopher D; Grigoriev, Roman O

    2015-06-01

    This paper investigates the properties of unstable single-spiral wave solutions arising in the Karma model of two-dimensional cardiac tissue. In particular, we discuss how such solutions can be computed numerically on domains of arbitrary shape and study how their stability, rotational frequency, and spatial drift depend on the size of the domain as well as the position of the spiral core with respect to the boundaries. We also discuss how the breaking of local Euclidean symmetry due to finite size effects as well as the spatial discretization of the model is reflected in the structure and dynamics of spiral waves. This analysis allows identification of a self-sustaining process responsible for maintaining the state of spiral chaos featuring multiple interacting spirals.

  14. Transition of spiral calcium waves between multiple stable patterns can be triggered by a single calcium spark in a fire-diffuse-fire model.

    PubMed

    Tang, Ai-Hui; Wang, Shi-Qiang

    2009-09-01

    Spiral patterns have been found in various nonequilibrium systems. The Ca(2+)-induced Ca(2+) release system in single cardiac cells is unique for highly discrete reaction elements, each giving rise to a Ca(2+) spark upon excitation. We imaged the spiral Ca(2+) waves in isolated cardiac cells and numerically studied the effect of system excitability on spiral patterns using a two-dimensional fire-diffuse-fire model. We found that under certain conditions, the system was able to display multiple stable patterns of spiral waves, each exhibiting different periods and distinct routines of spiral tips. Transition between these different patterns could be triggered by an internal fluctuation in the form of a single Ca(2+) spark.

  15. The instability of the spiral wave induced by the deformation of elastic excitable media

    NASA Astrophysics Data System (ADS)

    Ma, Jun; Jia, Ya; Wang, Chun-Ni; Li, Shi-Rong

    2008-09-01

    There are some similarities between the spiral wave in excitable media and in cardiac tissue. Much evidence shows that the appearance and instability of the spiral wave in cardiac tissue can be linked to one kind of heart disease. There are many models that can be used to investigate the formation and instability of the spiral wave. Cardiac tissue is excitable and elastic, and it is interesting to simulate the transition and instability of the spiral wave induced by media deformation. For simplicity, a class of the modified Fitzhugh-Nagumo (MFHN) model, which can generate a stable rotating spiral wave, meandering spiral wave and turbulence within appropriate parameter regions, will be used to simulate the instability of the spiral wave induced by the periodical deformation of media. In the two-dimensional case, the total acreage of elastic media is supposed to be invariable in the presence of deformation, and the problem is described with Lx × Ly = N × ΔxN × Δy = L'xL'y = N × Δx'N × Δy'. In our studies, elastic media are decentralized into N × N sites and the space of the adjacent sites is changed to simulate the deformation of elastic media. Based on the nonlinear dynamics theory, the deformation effect on media is simplified and simulated by perturbing the diffusion coefficients Dx and Dy with different periodical signals, but the perturbed diffusion coefficients are compensatory. The snapshots of our numerical results find that the spiral wave can coexist with the spiral turbulence, instability of the spiral wave and weak deformation of the spiral wave in different conditions. The ratio parameter ɛ and the frequency of deformation forcing play a deterministic role in inducing instability of the spiral wave. Extensive studies confirm that the instability of the spiral wave can be induced and developed only if an appropriate frequency for deformation is used. We analyze the power spectrum for the time series of the mean activator of four sampled sites which are selected symmetrically in different cases, such as the condition that the spiral wave coexists with the spiral turbulence, spiral wave without evident deformation, complete instability of the spiral wave (turbulence) and weak deformation of the spiral wave. It is found that more new peaks appear in the power spectrum and the distribution of frequency becomes sparser when the spiral wave encounters instability.

  16. Slowed atrial and atrioventricular conduction and depressed HRV in a murine model of hypertrophic cardiomyopathy.

    PubMed

    Lim, Wei-Wen; Baumert, Mathias; Neo, Melissa; Kuklik, Pawel; Ganesan, Anand N; Lau, Dennis H; Tsoutsman, Tatiana; Semsarian, Christopher; Sanders, Prashanthan; Saint, David A

    2016-01-01

    Hypertrophic cardiomyopathy (HCM) is a common heritable cardiac disorder with diverse clinical outcomes including sudden death, heart failure, and stroke. Depressed heart rate variability (HRV), a measure of cardiac autonomic regulation, has been shown to predict mortality in patients with cardiovascular disease. Cardiac autonomic remodelling in animal models of HCM are not well characterised. This study analysed Gly203Ser cardiac troponin-I transgenic (TG) male mice previously demonstrated to develop hallmarks of HCM by age 21 weeks. 33 mice aged 30 and 50 weeks underwent continuous electrocardiogram (ECG) recording for 30 min under anaesthesia. TG mice demonstrated prolonged P-wave duration (P < 0.001) and PR intervals (P < 0.001) compared to controls. Additionally, TG mice demonstrated depressed standard deviation of RR intervals (SDRR; P < 0.01), coefficient of variation of RR intervals (CVRR; P < 0.001) and standard deviation of heart rate (SDHR; P < 0.001) compared to controls. Additionally, total power was significantly reduced in TG mice (P < 0.05). No significant age-related difference in either strain was observed in ECG or HRV parameters. Mice with HCM developed slowed atrial and atrioventricular conduction and depressed HRV. These changes were conserved with increasing age. This finding may be indicative of atrial and ventricular hypertrophy or dysfunction, and perhaps an indication of worse clinical outcome in heart failure progression in HCM patients. © 2015 Wiley Publishing Asia Pty Ltd.

  17. Spatially extended versus frontal cerebral near-infrared spectroscopy during cardiac surgery: a case series identifying potential advantages

    NASA Astrophysics Data System (ADS)

    Rummel, Christian; Basciani, Reto; Nirkko, Arto; Schroth, Gerhard; Stucki, Monika; Reineke, David; Eberle, Balthasar; Kaiser, Heiko A.

    2018-01-01

    Stroke due to hypoperfusion or emboli is a devastating adverse event of cardiac surgery, but early detection and treatment could protect patients from an unfavorable postoperative course. Hypoperfusion and emboli can be detected with transcranial Doppler of the middle cerebral artery (MCA). The measured blood flow velocity correlates with cerebral oxygenation determined clinically by near-infrared spectroscopy (NIRS) of the frontal cortex. We tested the potential advantage of a spatially extended NIRS in detecting critical events in three cardiac surgery patients with a whole-head fiber holder of the FOIRE-3000 continuous-wave NIRS system. Principle components analysis was performed to differentiate between global and localized hypoperfusion or ischemic territories of the middle and anterior cerebral arteries. In one patient, we detected a critical hypoperfusion of the right MCA, which was not apparent in the frontal channels but was accompanied by intra- and postoperative neurological correlates of ischemia. We conclude that spatially extended NIRS of temporal and parietal vascular territories could improve the detection of critically low cerebral perfusion. Even in severe hemispheric stroke, NIRS of the frontal lobe may remain normal because the anterior cerebral artery can be supplied by the contralateral side directly or via the anterior communicating artery.

  18. Electrocardiographic J Wave and Cardiovascular Outcomes in the General Population (from the Atherosclerosis Risk In Communities Study).

    PubMed

    O'Neal, Wesley T; Wang, Yi Grace; Wu, Hau-Tieng; Zhang, Zhu-Ming; Li, Yabing; Tereshchenko, Larisa G; Estes, E Harvey; Daubechies, Ingrid; Soliman, Elsayed Z

    2016-09-15

    The association between the J wave, a key component of the early repolarization pattern, and adverse cardiovascular outcomes remains unclear. Inconsistencies have stemmed from the different methods used to measure the J wave. We examined the association between the J wave, detected by an automated method, and adverse cardiovascular outcomes in 14,592 (mean age = 54 ± 5.8 years; 56% women; 26% black) participants from the Atherosclerosis Risk In Communities (ARIC) study. The J wave was detected at baseline (1987 to 1989) and during follow-up study visits (1990 to 1992, 1993 to 1995, and 1996 to 1998) using a fully automated method. Sudden cardiac death, coronary heart disease death, and cardiovascular mortality were ascertained from hospital discharge records, death certificates, and autopsy data through December 31, 2010. A total of 278 participants (1.9%) had evidence of a J wave. Over a median follow-up of 22 years, 4,376 of the participants (30%) died. In a multivariable Cox regression analysis adjusted for demographics, cardiovascular risk factors, and potential confounders, the J wave was not associated with an increased risk of sudden cardiac death (hazard ratio [HR] 0.74, 95% CI 0.36 to 1.50), coronary heart disease death (HR 0.72, 95% CI 0.40 to 1.32), or cardiovascular mortality (HR 1.16, 95% CI 0.87 to 1.56). An interaction was detected for cardiovascular mortality by gender with men (HR 1.54, 95% CI 1.09 to 2.19) having a stronger association than women (HR 0.74, 95% CI 0.43 to 1.25; P-interaction = 0.030). In conclusion, our findings suggest that the J wave is a benign entity that is not associated with an increased risk for sudden cardiac arrest in middle-aged adults in the United States. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Utility of T-wave amplitude as a non-invasive risk marker of sudden cardiac death in hypertrophic cardiomyopathy.

    PubMed

    Sugrue, Alan; Killu, Ammar M; DeSimone, Christopher V; Chahal, Anwar A; Vogt, Josh C; Kremen, Vaclav; Hai, JoJo; Hodge, David O; Acker, Nancy G; Geske, Jeffrey B; Ackerman, Michael J; Ommen, Steve R; Lin, Grace; Noseworthy, Peter A; Brady, Peter A

    2017-01-01

    Sudden cardiac arrest (SCA) is the most devastating outcome in hypertrophic cardiomyopathy (HCM). We evaluated repolarisation features on the surface electrocardiogram (ECG) to identify the potential risk factors for SCA. Data was collected from 52 patients with HCM who underwent implantable cardioverter defibrillator (ICD) implantation. Leads V2 and V5 from the ECG closest to the time of ICD implant were utilised for measuring the Tpeak-Tend interval (Tpe), QTc, Tpe/QTc, T-wave duration and T-wave amplitude. The presence of the five traditional SCA-associated risk factors was assessed, as well as the HCM risk-SCD score. 16 (30%) patients experienced aborted cardiac arrest over 8.5±4.1 years, with 9 receiving an ICD shock and 7 receiving ATP. On univariate analysis, T-wave amplitude was associated with appropriate ICD therapy (HR per 0.1 mV 0.79, 95% CI 0.56 to 0.96, p=0.02). Aborted SCA was not associated with a greater mean QTc duration, Tpeak-Tend interval, T-wave duration, or Tpe/QT ratio. Multivariate analysis (adjusting for cardinal HCM SCA-risk factors) showed T-wave amplitude in Lead V2 was an independent predictor of risk (adjusted HR per 0.1 mV 0.74, 95% CI 0.57 to 0.97, p=0.03). Addition of T-wave amplitude in Lead V2 to the traditional risk factors resulted in significant improvement in risk stratification (C-statistic from 0.65 to 0.75) but did not improve the performance of the HCM SCD-risk score. T-wave amplitude is a novel marker of SCA in this high risk HCM population and may provide incremental predictive value to established risk factors. Further work is needed to define the role of repolarisation abnormalities in predicting SCA in HCM.

  20. Infarct-like acute myocarditis: relation between electrocardiographic findings and myocardial damage as assessed by cardiac magnetic resonance imaging.

    PubMed

    Nucifora, Gaetano; Miani, Daniela; Di Chiara, Antonio; Piccoli, Gianluca; Artico, Jessica; Puppato, Michela; Slavich, Gianaugusto; De Biasio, Marzia; Gasparini, Daniele; Proclemer, Alessandro

    2013-03-01

    Acute myocarditis (AM) may occasionally have an infarct-like presentation. The aim of the present study was to investigate the relation between electrocardiographic (ECG) findings in this group of patients and myocardial damage assessed by cardiac magnetic resonance imaging (MRI) with the late gadolinium enhancement (LGE) technique. Myocardial damage may be associated with ECG changes in infarct-like AM. Forty-one consecutive patients (36 males; mean age, 36 ± 12 years) with diagnosis of AM according to cardiac MRI Lake Louise criteria and infarct-like presentation were included. The relation between site of ST-segment elevation (STE), sum of STE (sumSTE), time to normalization of STE, and development of negative T wave with the extent of LGE (expressed as % of left ventricular mass [%LV LGE]), was evaluated. Most (80%) patients presented with inferolateral STE; mean sumSTE was 5 ± 3 mm. Normalization of STE occurred within 24 hours in 20 (49%) patients. Development of negative T wave occurred in 28 (68%) patients. Cardiac MRI showed LGE in all patients; mean %LV LGE was 9.6 ± 7.2%. Topographic agreement between site of STE and LGE was 68%. At multivariate analysis, sumSTE (β = 0.42, P < 0.001), normalization of STE >24 hours (β = 0.39, P < 0.001), and development of negative T wave (β = 0.49, P < 0.001) were independently related to %LV LGE. Analysis of the site of STE underestimates the extent of myocardial injury among patients with infarct-like myocarditis. However, some ECG features (ie, sumSTE, normalization of STE >24 hours, and development of negative T wave) may help to identify patients with larger areas of myocardial damage. © 2012 Wiley Periodicals, Inc.

  1. Tachycardia-dependent augmentation of "notched J waves" in a general patient population without ventricular fibrillation or cardiac arrest: not a repolarization but a depolarization abnormality?

    PubMed

    Aizawa, Yoshifusa; Sato, Masahito; Kitazawa, Hitoshi; Aizawa, Yoshiyasu; Takatsuki, Seiji; Oda, Eiji; Okabe, Masaaki; Fukuda, Keiichi

    2015-02-01

    J waves can be observed in individuals of the general population, but electrocardiographic characteristics are poorly understood. The purpose of this study was to examine the J-wave dynamicity in a general patient population. The responses of J waves (>0.1 mV above the isoelectric line in 2 contiguous leads) to varying RR intervals were analyzed. Patients with aborted sudden cardiac death, documented ventricular fibrillation, or a family history of sudden cardiac death were excluded. The J-wave amplitude was measured at baseline, in beats with short RR intervals in conducted atrial premature beats (APBs) or atrial stimulation during the electrophysiology study, and in the beats next to APBs with prolonged RR intervals. Mainly notched J waves were identified in 94 of 701 (24.5%) general patients (13.4%), and APBs were present in 23 of 94 (24.5%) patients. The mean baseline amplitude of J waves was 0.20 ± 0.06 mV at the baseline RR interval of 853 ± 152 ms, 0.25 ± 0.11 mV at the RR interval in the conducted APB of 545 ± 133 ms (P = .0018), and 0.19 ± 0.08 mV at the RR interval of 1146 ± 314 ms (P = .3102). The clinical characteristics were not different between patients with and without tachycardia-dependent augmentation of J waves. Augmentation of J waves was confirmed by the electrophysiology study: 0.28 ± 0.12 mV vs 0.42 ± 0.11 mV at baseline and in the beats of atrial stimulation, respectively (P = .0001). However, no bradycardia-dependent augmentation (>0.05 mV) was observed. Such tachycardia-dependent augmentation can represent depolarization abnormality rather than repolarization abnormality. J waves in a general patient population were augmented at shorter RR intervals, but not at prolonged RR intervals. Mechanistically, conduction delay is most likely responsible for this. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  2. Spiral waves characterization: Implications for an automated cardiodynamic tissue characterization.

    PubMed

    Alagoz, Celal; Cohen, Andrew R; Frisch, Daniel R; Tunç, Birkan; Phatharodom, Saran; Guez, Allon

    2018-07-01

    Spiral waves are phenomena observed in cardiac tissue especially during fibrillatory activities. Spiral waves are revealed through in-vivo and in-vitro studies using high density mapping that requires special experimental setup. Also, in-silico spiral wave analysis and classification is performed using membrane potentials from entire tissue. In this study, we report a characterization approach that identifies spiral wave behaviors using intracardiac electrogram (EGM) readings obtained with commonly used multipolar diagnostic catheters that perform localized but high-resolution readings. Specifically, the algorithm is designed to distinguish between stationary, meandering, and break-up rotors. The clustering and classification algorithms are tested on simulated data produced using a phenomenological 2D model of cardiac propagation. For EGM measurements, unipolar-bipolar EGM readings from various locations on tissue using two catheter types are modeled. The distance measure between spiral behaviors are assessed using normalized compression distance (NCD), an information theoretical distance. NCD is a universal metric in the sense it is solely based on compressibility of dataset and not requiring feature extraction. We also introduce normalized FFT distance (NFFTD) where compressibility is replaced with a FFT parameter. Overall, outstanding clustering performance was achieved across varying EGM reading configurations. We found that effectiveness in distinguishing was superior in case of NCD than NFFTD. We demonstrated that distinct spiral activity identification on a behaviorally heterogeneous tissue is also possible. This report demonstrates a theoretical validation of clustering and classification approaches that provide an automated mapping from EGM signals to assessment of spiral wave behaviors and hence offers a potential mapping and analysis framework for cardiac tissue wavefront propagation patterns. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. The concerted movement of the switch region of Troponin I in cardiac muscle thin filaments as tracked by conventional and pulsed (DEER) EPR.

    PubMed

    Potluri, Phani R; Chamoun, Jean; Cooke, James A; Badr, Myriam; Guse, Joanna A; Rayes, Roni; Cordina, Nicole M; McCamey, Dane; Fajer, Piotr G; Brown, Louise J

    2017-12-01

    The absence of a crystal structure of the calcium free state of the cardiac isoform of the troponin complex has hindered our understanding of how the simple binding of Ca 2+ triggers conformational changes in troponin which are then propagated to enable muscle contraction. Here we have used continuous wave (CW) and Double Electron-Electron Resonance (DEER) pulsed EPR spectroscopy to measure distances between TnI and TnC to track the movement of the functionally important regulatory 'switch' region of cardiac Tn. Spin labels were placed on the switch region of Troponin I and distances measured to Troponin C. Under conditions of high Ca 2+ , the interspin distances for one set (TnI151/TnC84) were 'short' (9-10Å) with narrow distance distribution widths (3-8Å) indicating the close interaction of the switch region with the N-lobe of TnC. Additional spin populations representative of longer interspin distances were detected by DEER. These longer distance populations, which were ∼16-19Å longer than the short distance populations, possessed notably broader distance distribution widths (14-29Å). Upon Ca 2+ removal, the interspin population shifted toward the longer distances, indicating the release of the switch region from TnC and an overall increase in disorder for this region. Together, our results suggest that under conditions of low Ca 2+ , the close proximity of the TnI switch region to TnC in the cardiac isoform is necessary for promoting the interaction between the regulatory switch helix with the N-lobe of cardiac Troponin C, which, unlike the skeletal isoform, is largely in a closed conformation. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Cardiac radiology: centenary review.

    PubMed

    de Roos, Albert; Higgins, Charles B

    2014-11-01

    During the past century, cardiac imaging technologies have revolutionized the diagnosis and treatment of acquired and congenital heart disease. Many important contributions to the field of cardiac imaging were initially reported in Radiology. The field developed from the early stages of cardiac imaging, including the use of coronary x-ray angiography and roentgen kymography, to nowadays the widely used echocardiographic, nuclear medicine, cardiac computed tomographic (CT), and magnetic resonance (MR) applications. It is surprising how many of these techniques were not recognized for their potential during their early inception. Some techniques were described in the literature but required many years to enter the clinical arena and presently continue to expand in terms of clinical application. The application of various CT and MR contrast agents for the diagnosis of myocardial ischemia is a case in point, as the utility of contrast agents continues to expand the noninvasive characterization of myocardium. The history of cardiac imaging has included a continuous process of advances in our understanding of the anatomy and physiology of the cardiovascular system, along with advances in imaging technology that continue to the present day.

  5. High Resolution Magnetic Images of Planar Wave Fronts Reveal Bidomain Properties of Cardiac Tissue

    PubMed Central

    Holzer, Jenny R.; Fong, Luis E.; Sidorov, Veniamin Y.; Wikswo, John P.; Baudenbacher, Franz

    2004-01-01

    We magnetically imaged the magnetic action field and optically imaged the transmembrane potentials generated by planar wavefronts on the surface of the left ventricular wall of Langendorff-perfused isolated rabbit hearts. The magnetic action field images were used to produce a time series of two-dimensional action current maps. Overlaying epifluorescent images allowed us to identify a net current along the wavefront and perpendicular to gradients in the transmembrane potential. This is in contrast to a traditional uniform double-layer model where the net current flows along the gradient in the transmembrane potential. Our findings are supported by numerical simulations that treat cardiac tissue as a bidomain with unequal anisotropies in the intra- and extracellular spaces. Our measurements reveal the anisotropic bidomain nature of cardiac tissue during plane wave propagation. These bidomain effects play an important role in the generation of the whole-heart magnetocardiogram and cannot be ignored. PMID:15377521

  6. Spatial nonuniformity of contraction causes arrhythmogenic Ca2+ waves in rat cardiac muscle.

    PubMed

    Ter Keurs, Henk E D J; Wakayama, Yuji; Miura, Masahito; Stuyvers, Bruno D; Boyden, Penelope A; Landesberg, Amir

    2005-06-01

    Landesberg and Sideman's four state model of the cardiac cross-bridge (XB) hypothesizes a feedback of force development to Ca(2+) binding by troponin C (TnC). We have further modeled this behavior and observed that the force (F)-Ca(2+) relationship as well as the F-sarcomere length (SL) relationship and the time course of F and Ca(2+) transients in cardiac muscle can be reproduced faithfully by a single effect of F on deformation of the TnC-Ca complex and, thereby, on the dissociation rate of Ca(2+). Furthermore, this feedback predicts that rapid decline of F in the activated sarcomere causes release of Ca(2+) from TnC-Ca(2+), which is sufficient to initiate arrhythmogenic Ca(2+) release from the sarcoplasmic reticulum (SR). This work investigated the initiation of Ca(2+) waves underlying triggered propagated contractions (TPCs) in rat cardiac trabeculae under conditions that simulate functional nonuniformity caused by mechanical or ischemic local damage of the myocardium. A mechanical discontinuity along the trabeculae was created by exposing the preparation to a small constant flow jet of solution that reduces excitation-contraction coupling in myocytes within that segment. Force was measured, and SL as well as [Ca(2+)](i) were measured regionally. When the jet contained caffeine, 2,3-butanedione monoxime or low-[Ca(2+)], muscle-twitch F decreased and the sarcomeres in the exposed segment were stretched by shortening the normal regions outside the jet. During relaxation, the sarcomeres in the exposed segment shortened rapidly. Short trains of stimulation at 2.5 Hz reproducibly caused Ca(2+) waves to rise from the borders exposed to the jet. Ca(2+) waves started during F relaxation of the last stimulated twitch and propagated into segments both inside and outside of the jet. Arrhythmias, in the form of nondriven rhythmic activity, were triggered when the amplitude of the Ca(2+) wave increased by raising [Ca(2+)](o). The arrhythmias disappeared when the muscle uniformity was restored by turning the jet off. These results show that nonuniform contraction can cause Ca(2+) waves underlying TPCs, and suggest that Ca(2+) dissociated from myofilaments plays an important role in the initiation of arrhythmogenic Ca(2+) waves.

  7. Memory effects, transient growth, and wave breakup in a model of paced atrium

    NASA Astrophysics Data System (ADS)

    Garzón, Alejandro; Grigoriev, Roman O.

    2017-09-01

    The mechanisms underlying cardiac fibrillation have been investigated for over a century, but we are still finding surprising results that change our view of this phenomenon. The present study focuses on the transition from normal rhythm to spiral wave chaos associated with a gradual increase in the pacing rate. While some of our findings are consistent with existing experimental, numerical, and theoretical studies of this problem, one result appears to contradict the accepted picture. Specifically we show that, in a two-dimensional model of paced homogeneous atrial tissue, transition from discordant alternans to conduction block, wave breakup, reentry, and spiral wave chaos is associated with the transient growth of finite amplitude disturbances rather than a conventional instability. It is mathematically very similar to subcritical, or bypass, transition from laminar fluid flow to turbulence, which allows many of the tools developed in the context of fluid turbulence to be used for improving our understanding of cardiac arrhythmias.

  8. Utility of a novel risk score for prediction of ventricular tachycardia and cardiac death in chronic Chagas disease - the SEARCH-RIO study

    PubMed Central

    Benchimol-Barbosa, P.R.; Tura, B.R.; Barbosa, E.C.; Kantharia, B.K.

    2013-01-01

    The SEARCH-RIO study prospectively investigated electrocardiogram (ECG)-derived variables in chronic Chagas disease (CCD) as predictors of cardiac death and new onset ventricular tachycardia (VT). Cardiac arrhythmia is a major cause of death in CCD, and electrical markers may play a significant role in risk stratification. One hundred clinically stable outpatients with CCD were enrolled in this study. They initially underwent a 12-lead resting ECG, signal-averaged ECG, and 24-h ambulatory ECG. Abnormal Q-waves, filtered QRS duration, intraventricular electrical transients (IVET), 24-h standard deviation of normal RR intervals (SDNN), and VT were assessed. Echocardiograms assessed left ventricular ejection fraction. Predictors of cardiac death and new onset VT were identified in a Cox proportional hazard model. During a mean follow-up of 95.3 months, 36 patients had adverse events: 22 new onset VT (mean±SD, 18.4±4‰/year) and 20 deaths (26.4±1.8‰/year). In multivariate analysis, only Q-wave (hazard ratio, HR=6.7; P<0.001), VT (HR=5.3; P<0.001), SDNN<100 ms (HR=4.0; P=0.006), and IVET+ (HR=3.0; P=0.04) were independent predictors of the composite endpoint of cardiac death and new onset VT. A prognostic score was developed by weighting points proportional to beta coefficients and summing-up: Q-wave=2; VT=2; SDNN<100 ms=1; IVET+=1. Receiver operating characteristic curve analysis optimized the cutoff value at >1. In 10,000 bootstraps, the C-statistic of this novel score was non-inferior to a previously validated (Rassi) score (0.89±0.03 and 0.80±0.05, respectively; test for non-inferiority: P<0.001). In CCD, surface ECG-derived variables are predictors of cardiac death and new onset VT. PMID:24270912

  9. Wave intensity analysis in mice: an ultrasound-based study in the abdominal aorta and common carotid artery

    NASA Astrophysics Data System (ADS)

    Di Lascio, N.; Kusmic, C.; Stea, F.; Faita, F.

    2017-03-01

    Wave Intensity Analysis (WIA) can provide parameters representative of the interaction between the vascular network and the heart. It has been already demonstrated that WIA-derived biomarkes have a quantitative physiological meaning. Aim of this study was to develop an image process algorithm for performing non-invasive WIA in mice and correlate commonly used cardiac function parameters with WIA-derived indexes. Sixteen wild-type male mice (8 weeks-old) were imaged with high-resolution ultrasound (Vevo 2100). Abdominal aorta and common carotid pulse wave velocities (PWVabd, PWVcar) were obtained processing B-Mode and PW-Doppler images and employed to assess WIA. Amplitudes of the first (W1abd, W1car) and the second (W2abd, W2car) local maxima and minimum (Wbabd,Wbcar) were evaluated; areas under the negative part of the curve were also calculated (NAabd, NAcar). Cardiac output (CO), ejection fraction (EF) fractional shortening (FS) and stroke volume (SV) were estimated; strain analysis provided strain and strain rate values for longitudinal, radial and circumferential directions (LS, LSR, RS, RSR, CS, CSR). Isovolumetric relaxation time (IVRT) was calculated from mitral inflow PW-Doppler images; IVRT values were normalized for cardiac cycle length. W1abd was correlated with LS (R=0.65) and LSR (R=0.59), while W1car was correlated with CO (R=0.58), EF (R=0.72), LS (R=0.65), LSR (R=0.89), CS (R=0.71), CSR (R=0.70). Both W2abd and W2car were not correlated with IVRT. Carotid artery WIA-derived parameters are more representative of cardiac function than those obtained from the abdominal aorta. The described US-based method can provide information about cardiac function and cardio-vascular interaction simply studying a single vascular site.

  10. Clinical Significance of Epsilon Waves in Arrhythmogenic Cardiomyopathy.

    PubMed

    Protonotarios, Alexandros; Anastasakis, Aris; Tsatsopoulou, Adalena; Antoniades, Loizos; Prappa, Efstathia; Syrris, Petros; Tousoulis, Dimitrios; McKENNA, William J; Protonotarios, Nikos

    2015-07-16

    Epsilon waves are hallmark features of arrhythmogenic cardiomyopathy (ACM) but information about their clinical significance is variable. We evaluated epsilon wave prevalence, characteristics, and their clinical significance in an ACM population. Eighty-six unselected patients fulfilling the 2010 Task Force criteria were enrolled. Seventy-six of them were carriers of desmosomal mutations. All subjects were serially evaluated with standard 12-lead ECG and 2-dimensional echocardiography. Epsilon waves were evaluated in all precordial and inferior leads. Novel parameters assessed included their duration and precordial/inferior lead extension. Twenty-five subjects (29%) had epsilon waves that were present in lead V3 and beyond in 9, and in the inferior leads in 7. Epsilon waves were associated with right ventricular outflow tract (RVOT) (P = 0.001) but not RV posterior wall (P = 0.21), RV apex (P = 0.30), or left ventricular (P = 0.94) wall motion abnormalities. Patients with epsilon waves had increased RVOT diameter (P < 0.0001). Extension of epsilon waves in lead V3 and beyond was associated with increased epsilon wave duration (P = 0.002) and RVOT diameter (P = 0.04). The duration of epsilon waves was positively correlated with RVOT diameter (r = 0.70, P = 0.0001). Epsilon waves were also associated with episodes of sustained ventricular tachycardia (P = 0.004) but not with heart failure (P = 0.41) or sudden cardiac death (P = 0.31). Detection of epsilon waves on 12-lead ECG reflects significant RVOT involvement, which was associated with episodes of sustained ventricular tachycardia but not sudden cardiac death. © 2015 Wiley Periodicals, Inc.

  11. Reappraisal of quantitative evaluation of pulmonary regurgitation and estimation of pulmonary artery pressure by continuous wave Doppler echocardiography.

    PubMed

    Lei, M H; Chen, J J; Ko, Y L; Cheng, J J; Kuan, P; Lien, W P

    1995-01-01

    This study assessed the usefulness of continuous wave Doppler echocardiography and color flow mapping in evaluating pulmonary regurgitation (PR) and estimating pulmonary artery (PA) pressure. Forty-three patients were examined, and high quality Doppler spectral recordings of PR were obtained in 32. All patients underwent cardiac catheterization, and simultaneous PA and right ventricular (RV) pressures were recorded in 17. Four Doppler regurgitant flow velocity patterns were observed: pandiastolic plateau, biphasic, peak and plateau, and early diastolic triangular types. The peak diastolic and end-diastolic PA-to-RV pressure gradients derived from the Doppler flow profiles correlated well with the catheter measurements (r = 0.95 and r = 0.95, respectively). As PA pressure increased, the PR flow velocity became higher; a linear relationship between either systolic or mean PA pressure and Doppler-derived peak diastolic pressure gradient was noted (r = 0.90 and 0.94, respectively). Based on peak diastolic gradients of < 15, 15-30 or > 30 mm Hg, patients could be separated as those with mild, moderate or severe pulmonary hypertension, respectively (p < 0.05). A correlation was also observed between PA diastolic pressure and Doppler-derived end-diastolic pressure gradient (r = 0.91). Moreover, the Doppler velocity decay slope of PR closely correlated with that derived from the catheter method (r = 0.98). The decay slope tended to be steeper with the increment in regurgitant jet area and length obtained from color flow mapping. In conclusion, continuous wave Doppler evaluation of PR is a useful means for noninvasive estimation of PA pressure, and the Doppler velocity decay slope seems to reflect the severity of PR.

  12. Using Visual Methods to Understand Physical Activity Maintenance following Cardiac Rehabilitation

    PubMed Central

    Hardcastle, Sarah J.

    2015-01-01

    Few studies have explored the factors associated with long-term maintenance of exercise following cardiac rehabilitation. The present study used auto-photography and interviews to explore the factors that influence motivation and continued participation in physical activity among post cardiac rehabilitation patients. Twenty-three semi-structured interviews were conducted alongside participant-selected photographs or drawings with participants that had continued participation in physical activity for at least two years following the cardiac rehabilitation programme. Participants were recruited from circuit training classes in East Sussex in the UK. Thematic content analysis revealed seven main themes: fear of death and ill health avoidance, critical incidents, overcoming aging, social influences, being able to enjoy life, provision of routine and structure, enjoyment and psychological well-being. Fear of death, illness avoidance, overcoming aging, and being able to enjoy life were powerful motives for continued participation in exercise. The social nature of the exercise class was also identified as a key facilitator of continued participation. Group-based exercise suited those that continued exercise participation post cardiac rehabilitation and fostered adherence. PMID:26381147

  13. Analysis of the O-wave in acute right ventricular apex impedance measurements with a standard pacing lead in animals.

    PubMed

    Järverud, K; Ollmar, S; Brodin, L A

    2002-09-01

    Modern pacemakers (implantable devices used for maintaining an appropriate heart rate in patients) can use an intracardiac ventricular impedance signal for physiological cardiac stimulation control. Intracardiac ventricular impedance from nine animal subjects is analysed and presented (seven sheep: 49.0 +/- 6.5 kg, sinus rhythm 100.3 +/- 16.5 beats min(-1), average impedance 629.8 +/- 72.6 ohms; and two dogs: 30 kg each, sinus rhythm 86.0 beats min(-1), 862.1 ohms and 134.0 beats min(-1), 1114.6 ohms, respectively). The averaged curve and standard deviation curve of the impedance in sinus rhythm were analysed in MATLAB to clarify and study consistent impedance shape over one heart cycle. In eight of nine (89%) animal subjects, a consistent impedance slope change (notch) was observed in the early stage of the cardiac filling phase. This result was reproduced in an additional subject with simultaneous echocardiographical measurements of mitral valve blood flow. The notch occured soon after rapid early filling (E-wave in mitral flow) but prior to ventricular filling caused by atrial contraction, indicating that the impedance notch was caused by rapid ventricular filling and that it might be a sensed feature of diagnostic value. The intracardiac impedance notch in the present study had similar features to the non-invasive transthoracic impedance O-wave reported by others, and it is shown here that an O-wave is found in intracardiac impedance signals, strongly suggesting that the non-invasive O-wave is caused by cardiac events.

  14. Echocardiography.

    PubMed Central

    Chambers, J. B.; Monaghan, M. J.; Jackson, G.

    1988-01-01

    Imaging echocardiography is an important extension of the clinical examination and will answer most questions in an emergency-for example, whether an enlarged cardiac shadow on the chest radiograph represents ventricular dilatation or an effusion. Doppler ultrasonography is essential for hospitals with an interest in cardiology because it provides direct haemodynamic data that are complementary to imaging. It requires more skill than imaging and may also be time consuming. Colour flow Doppler mapping is speedy and simple to use and aids the interpretation of continuous wave Doppler. It is therefore a natural companion to conventional Doppler, but there would have to be a high clinical load to justify its purchase. Images FIG 3 FIG 4 FIG 4 FIG 5 FIG 6 PMID:3143434

  15. Non-invasive electrocardiogram detection of in vivo zebrafish embryos using electric potential sensors

    NASA Astrophysics Data System (ADS)

    Rendon-Morales, E.; Prance, R. J.; Prance, H.; Aviles-Espinosa, R.

    2015-11-01

    In this letter, we report the continuous detection of the cardiac electrical activity in embryonic zebrafish using a non-invasive approach. We present a portable and cost-effective platform based on the electric potential sensing technology, to monitor in vivo electrocardiogram activity from the zebrafish heart. This proof of principle demonstration shows how electrocardiogram measurements from the embryonic zebrafish may become accessible by using electric field detection. We present preliminary results using the prototype, which enables the acquisition of electrophysiological signals from in vivo 3 and 5 days-post-fertilization zebrafish embryos. The recorded waveforms show electrocardiogram traces including detailed features such as QRS complex, P and T waves.

  16. [CHANGE OF CHARACTER OF INTERSYSTEMIC INTERACTIONS IN NEWBORN RAT PUPS UNDER CONDITIONS OF A DECREASE OF MOTOR ACTIVITY].

    PubMed

    Sizonov, V A; Dmitrieva, L E; Kuznetsov, S V

    2015-01-01

    Interaction of slow-wave.rhythmic components of cardiac, respiratory.and motor activity was investigated in newborn rat pups on the first day after birth under normal conditions and after pharmacological depression of spontaneous periodic motor activity (SPMA) produced by injecting myocuran (myanesin) at low (100 mg/pg, i/p) and maximal (235 mg/pg, i/p) dosages. The data obtained allow to infer that in rat pups after birth the intersystemic interactions are realized mainly via slow-wave oscillations of about-one- and many-minute ranges whereas the rhythms of decasecond range do not play a significant role in integrative processes. Injection of miocuran at a dose causing no muscle relaxation and no inhibition of motor activity produces changes of the cardiac and respiratory rhythms as well as a transitory decrease of the magnitude of coordinate relations mediated by the rhythms of about-one- and many-minute ranges. The consequences of muscle relaxant injection were found to be more significant for intersystemic interactions with participation of the respiratory system. An increase of the dosage and, correspondingly, the total inhibition of SPMA is accompanied by reduction of the slow-wave components from the pattern of cardiac and respiratory rhythms. The cardiorespiratory interactions, more expressed in intact rat pups, are reduced in the about-one- and many-minute ranges of modulation whereas in the decasecond range of modulation they are slightly increased. Key words: early ontogenesis, intersystemic interactions, cardiac rhythm, respiration, motor activity, myocuran (myanesin).

  17. Clinical Significance of J Waves in Patients Undergoing Therapeutic Hypothermia for Out-of-Hospital Cardiac Arrest.

    PubMed

    Harhash, Ahmed; Gussak, Ihor; Cassuto, James; Winters, Stephen L

    2017-02-01

    Hypothermia is associated with the development of J waves. However, little is known about the impact of these electrocardiogram (ECG) findings on the development of ventricular arrhythmias and patient outcomes during therapeutic hypothermia (TH) postresuscitation from out-of-hospital cardiac arrest (OHCA). We investigated the prevalence of J waves in OHCA patients prior to and during TH. Additionally, we explored the incidence of atrial and ventricular arrhythmias and in-hospital mortality for patients with and without J waves either at baseline, during TH, or both. We conducted a retrospective analysis of patients who suffered OHCA and underwent TH (goal temperature of 32-34°C). Fifty-nine patients were stratified dependent upon the presence of or the development of J waves on surface ECGs. Descriptive analysis and logistic regression modeling were used to assess the population differences and mortality, respectively, between patients who developed J waves during TH and those who did not. There was no difference in the development of in-hospital atrial or ventricular arrhythmias between patients with J waves present during TH (16%) and those without (17.6%, P = 0.834). Compared to patients without J waves at baseline and during TH, those with J waves present both at baseline and during TH had significantly worse survival (hazard ratio = 12.42, P = 0.046). While J waves are common ECG findings during TH in patients resuscitated from OHCA, our study demonstrated an increase in mortality for patients with J waves present both at baseline and during TH. © 2016 Wiley Periodicals, Inc.

  18. Cardiac MRI-confirmed mesalamine-induced myocarditis

    PubMed Central

    Baker, William L; Saulsberry, Whitney J; Elliott, Kaitlyn; Parker, Matthew W

    2015-01-01

    A 38-year-old Caucasian man with a medical history significant for inflammatory bowel disease (IBD) and mesalamine use presented to the emergency department with stabbing, pleuritic, substernal chest pain over the previous 2 days. Findings of leucocytosis, elevated cardiac enzymes and inflammatory markers, T-wave or ST-segment abnormalities and left ventricular systolic dysfunction suggested mesalamine-induced myocarditis. However, a cardiac MRI confirmed the diagnosis. Signs and symptoms improved within days of withdrawal of mesalamine, and initiation of corticosteroids and follow-up studies within the next year were unremarkable. Importantly, the diagnosis of mesalamine-induced myocarditis confirmed via cardiac MRI is a step rarely performed in published cases. PMID:26341161

  19. T wave amplitude in lead aVR as a novel diagnostic marker for cardiac sarcoidosis.

    PubMed

    Tanaka, Yoshihiro; Konno, Tetsuo; Yoshida, Shohei; Tsuda, Toyonobu; Sakata, Kenji; Furusho, Hiroshi; Takamura, Masayuki; Yoshimura, Kenichi; Yamagishi, Masakazu; Hayashi, Kenshi

    2017-03-01

    It is vital to identify cardiac involvement (CI) in patients with sarcoidosis as the condition could initially lead to sudden cardiac death. Although the T wave amplitude in lead aVR (TWAaVR) is reportedly associated with adverse cardiac events in various cardiovascular diseases, only scarce data are available concerning the utility of lead aVR in identifying CI in patients with sarcoidosis. We retrospectively investigated the diagnostic values of TWAaVR in patients with sarcoidosis in comparison with conventional electrocardiography parameters such as bundle branch block (BBB). From January 2006 to December 2014, 93 consecutive patients with sarcoidosis were enrolled (mean age, 55.7 ± 15.7 years; male, 31 %; cardiac involvement, n = 26). TWAaVR showed the greatest sensitivity (39 %) and specificity (92 %) in distinguishing between sarcoidosis patients with and without CI, at a cutoff value of -0.08 mV. The diagnostic value of BBB for cardiac involvement was significantly improved when combined with TWAaVR (sensitivity: 61-94 %, specificity: 97-89 %, area under the curve: 0.79-0.92, p = 0.018). Multivariate logistic regression analysis indicated that TWAaVR and BBB were independent electrocardiography parameters associated with CI. In summary, we observed that sarcoidosis patients exhibiting a high TWAaVR were likely to have CI. Thus, the application of a combination of BBB with TWAaVR may be useful when screening for CI in sarcoidosis patients.

  20. [Hemodynamic changes in hypoglycemic shock].

    PubMed

    Gutiérrez, C; Piza, R; Chousleb, A; Hidalgo, M A; Ortigosa, J L

    1977-01-01

    Severe hypoglycemia may be present in seriously ill patients; if it is not corrected opportunely a series of neuroendocrinal mechanisms take place aimed at correcting metabolic alterations. These mechanisms can produce hemodynamic alterations as well. Nine mongrel dogs were studied with continuous registration of: blood pressure, central venous pressure, cardiac frequency, respiratory frequency, electrocardiogram and first derivative (Dp/Dt). Six dogs received crystalline (fast acting) insuline intravenously (group 1). After hemodynamic changes were registered hypoglycemia was corrected with 50 per cent glucose solution. Complementary insuline doses were administered to three dogs (group 2); in this group hypoglycemia was not corrected. In group 1 during hypoglycemia there was an increase in blood pressure, central venous pressure, cardiac frequency, respiratory frequency and Dp/Dt, and changes in QT and T wave on the EKG; these changes were partially reversible after hypoglycemia was corrected. The above mentioned alterations persisted in group 2, breathing became irregular irregular and respiratory arrest supervened. It can be inferred that the hemodynamic response to hypoglycemia is predominantly adrenergic. The role of catecolamines, glucocorticoides, glucagon, insuline, cyclic AMP in metabolic and hemodynamic alterations consecutive to hypoglycemia are discussed.

  1. Ubiquitous health monitoring and real-time cardiac arrhythmias detection: a case study.

    PubMed

    Li, Jian; Zhou, Haiying; Zuo, Decheng; Hou, Kun-Mean; De Vaulx, Christophe

    2014-01-01

    As the symptoms and signs of heart diseases that cause sudden cardiac death, cardiac arrhythmia has attracted great attention. Due to limitations in time and space, traditional approaches to cardiac arrhythmias detection fail to provide a real-time continuous monitoring and testing service applicable in different environmental conditions. Integrated with the latest technologies in ECG (electrocardiograph) analysis and medical care, the pervasive computing technology makes possible the ubiquitous cardiac care services, and thus brings about new technical challenges, especially in the formation of cardiac care architecture and realization of the real-time automatic ECG detection algorithm dedicated to care devices. In this paper, a ubiquitous cardiac care prototype system is presented with its architecture framework well elaborated. This prototype system has been tested and evaluated in all the clinical-/home-/outdoor-care modes with a satisfactory performance in providing real-time continuous cardiac arrhythmias monitoring service unlimitedly adaptable in time and space.

  2. Subtle alternating electrocardiographic morphology as an indicator of decreased cardiac electrical stability

    NASA Technical Reports Server (NTRS)

    Smith, J. M.; Blue, B.; Clancy, E.; Valeri, C. R.; Cohen, R. J.

    1985-01-01

    Observations from finite-element computer models, together with analytic developments based on percolation theory have suggested that subtle fluctuations of ECG morphology might serve as an indicator diminished cardiac electrical stability. With fixed-rate atrial pacing in canines, we have previously observed a pattern of alternation in T wave energy which correlated with cardiac electrical stability. We report here on a series of 20 canine experiments in which cardiac electrical stability (measured via Ventricular Fibrillation Threshold determination) was compared to a non-degenerate, multidimensional measurement of the degree of alternating activity present in the ECG complex morphology. The decrease in cardiac electrical stability brought on by both coronary artery occlusion and systemic hypothermia was consistently accompanied by subtle alternation in ECG morphology, with the absolute degree of alternating activity being significantly (negatively) correlated with cardiac electrical stability.

  3. Demonstration of cardiac rotor and source mapping techniques in embryonic chick monolayers

    NASA Astrophysics Data System (ADS)

    You, Min Ju; Langfield, Peter; Campanari, Lucas; Dobbs, Matt; Shrier, Alvin; Glass, Leon

    2017-09-01

    Excitable media, such as the heart, display propagating waves with different geometries including target patterns and rotors (spiral waves). Collision of two waves leads to annihilation of both. We present algorithms for data processing and analysis to identify the core of rotors. In this work, we show that as the spatial sampling resolution decreases it becomes increasingly difficult to identify rotors—there are instances of false negatives and false positives. These observations are relevant to current controversies concerning the role of rotors in the initiation, maintenance, and treatment of cardiac arrhythmias, especially atrial fibrillation. Currently some practitioners target the core of rotors for ablation, but the effectiveness of this procedure has been questioned. In view of the difficulties inherent in the identification of rotors, we conclude that methods to identify rotors need to first be validated prior to assessing the efficacy of ablation.

  4. Suppression of turbulence by heterogeneities in a cardiac model with fiber rotation

    NASA Astrophysics Data System (ADS)

    Zhang, Zhihui; Steinbock, Oliver

    2017-09-01

    Electrical scroll wave turbulence in human ventricles is associated with ventricular fibrillation and sudden cardiac death. We perform three-dimensional simulations on the basis of the anisotropic Fenton-Karma model and show that macroscopic, insulating heterogeneities (e.g., blood vessels) can cause the spontaneous formation of pinned scroll waves. The wave field of these vortices is periodic, and their frequencies are sufficiently high to push the free, turbulent vortices into the system boundaries where they annihilate. Our study considers cylindrical heterogeneities with radii in the range of 0.1 to 2 cm that extend either in the transmural or a perpendicular direction. Thick cylinders cause the spontaneous formation of multi-armed rotors according to a radius-dependence that is explained in terms of two-dimensional dynamics. For long cylinders, local pinning contacts spread along the heterogeneity by fast and complex self-wrapping.

  5. Abnormal cardiovascular responses induced by localized high power microwave exposure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu, S.-T; Brown, D.O.; Johnson, C.E.

    1992-05-01

    A hypothesis of microwave-induced circulatory under perfusion was tested in ketamine anesthetized rats whose heart rate, mean arterial pressure, pulse pressure, respiration rate, and body temperatures were monitored continuously. Fifty-eight ventral head and neck exposures in a waveguide consisted of sham-exposure and exposure to continuous wave (CW) and pulsed 1.25 GHz microwaves for 5 min. The 0.5 Hz and 16 Hz pulsemodulated microwaves were delivered at 400 kW peak power. The CW microwaves were 2 and 6.4 W. The average specific absorption rate was 4.75 W/kg per watt transmitted in the brain and 17.15 W/kg per watt transmitted in themore » neck. Respiration rate and mean arterial pressure were not altered. Changes in heart rate and pulse pressure were observed in rats exposed to higher power but not to the lower average power microwaves. Depression of pulse pressure, an indication of a decrease in stroke volume, and increased or decreased heart rate were noted in presence of whole-body hyperthermia. The cardiac output of those animals exposed to higher average power microwaves was considered to be below normal as hypothesized. Decreased cardiac output and normal mean arterial pressure resulted in an increase in the total peripheral resistance which was contrary to the anticipated thermal response of animals.« less

  6. Mitral valve prolapse: an underestimated cause of sudden cardiac death—a current review of the literature

    PubMed Central

    Tzatzaki, Eleni; Spartalis, Eleftherios; Athanasiou, Antonios; Moris, Demetrios; Damaskos, Christos; Garmpis, Nikolaos; Voudris, Vassilis

    2017-01-01

    Mitral valve prolapse (MVP) is a common valve abnormality in general population. Despite the general belief of a benign disorder, several articles since the 1980s report sudden cardiac death (SCD) in MVP patients, with a substantial percentage of asymptomatic young individuals. The problem is to detect those patients at increased risk and implement methods that are suitable to prevent cardiac arrest. This review investigates the correlation between MVP and SCD, the understanding of the pathophysiology, the strategies for detecting those at risk and treatment options. A complete literature survey was performed using PubMed database search to gather available information regarding MVP and SCD. A total of 33 studies met selection criteria for inclusion in the review. MVP is an underrated cause of arrhythmic SCD. The subset of patients with malignant MVP who may be at greater risk for SCD is characterized by young women with bileaflet MVP, biphasic or inverted T waves in the inferior leads, and frequent complex ventricular ectopic activity with documented ventricular bigeminy or ventricular tachycardia (VT) and premature ventricular contractions (PVCs) configurations of outflow tract alternating with fascicular origin or papillary muscle. MVP is a common condition in the general population and is often encountered in asymptomatic individuals. The existing literature continues to generate significant controversy regarding the association of MVP with ventricular arrhythmias and SCD. Early echocardiography and cardiac magnetic resonance (CMR) are essential, as is a greater understanding of the potential electrophysiological processes of primary arrhythmogenesis and the evaluation of the genetic substrate. PMID:29312750

  7. Mitral valve prolapse: an underestimated cause of sudden cardiac death-a current review of the literature.

    PubMed

    Spartalis, Michael; Tzatzaki, Eleni; Spartalis, Eleftherios; Athanasiou, Antonios; Moris, Demetrios; Damaskos, Christos; Garmpis, Nikolaos; Voudris, Vassilis

    2017-12-01

    Mitral valve prolapse (MVP) is a common valve abnormality in general population. Despite the general belief of a benign disorder, several articles since the 1980s report sudden cardiac death (SCD) in MVP patients, with a substantial percentage of asymptomatic young individuals. The problem is to detect those patients at increased risk and implement methods that are suitable to prevent cardiac arrest. This review investigates the correlation between MVP and SCD, the understanding of the pathophysiology, the strategies for detecting those at risk and treatment options. A complete literature survey was performed using PubMed database search to gather available information regarding MVP and SCD. A total of 33 studies met selection criteria for inclusion in the review. MVP is an underrated cause of arrhythmic SCD. The subset of patients with malignant MVP who may be at greater risk for SCD is characterized by young women with bileaflet MVP, biphasic or inverted T waves in the inferior leads, and frequent complex ventricular ectopic activity with documented ventricular bigeminy or ventricular tachycardia (VT) and premature ventricular contractions (PVCs) configurations of outflow tract alternating with fascicular origin or papillary muscle. MVP is a common condition in the general population and is often encountered in asymptomatic individuals. The existing literature continues to generate significant controversy regarding the association of MVP with ventricular arrhythmias and SCD. Early echocardiography and cardiac magnetic resonance (CMR) are essential, as is a greater understanding of the potential electrophysiological processes of primary arrhythmogenesis and the evaluation of the genetic substrate.

  8. Ethical and legal issues in donation after cardiac death in Italy.

    PubMed

    Bruzzone, P

    2010-05-01

    In Italy death of a human being must be declared either after brain death or after 20 minutes of cardiac arrest, certified by continuous electrocardiography (EKG) recording. It is my personal opinion that in such circumstances after cardiac death (DCD) will allow at best only the retrieval of few marginal kidneys and some tissues, and therefore will not be very helpful for our waiting list patients. I suggest instead modifying first the Italian law in order to be able to declare cardiac death after only 5 minutes of cardiac arrest, certified by continuous EKG recording. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  9. Positive T wave in lead aVR as an independent predictor for 1-year major adverse cardiac events in patients with first anterior wall ST-segment elevation myocardial infarction.

    PubMed

    Kobayashi, Akihiro; Misumida, Naoki; Aoi, Shunsuke; Kanei, Yumiko

    2017-11-01

    Positive T wave in lead aVR has been shown to predict an adverse in-hospital outcome in patients with anterior wall ST-segment elevation myocardial infarction (STEMI). However, the prognostic value of positive T wave in lead aVR on a long-term outcome has not been fully explored. We performed a retrospective analysis of 190 consecutive patients with first anterior wall STEMI who underwent an emergent coronary angiogram. Patients were divided into those with positive T wave > 0 mV and those with negative T wave ≦ 0 mV in lead aVR. Baseline and angiographic characteristics, and in-hospital revascularization procedures were recorded. In addition, in-hospital and 1-year major adverse cardiac events (MACE) including death, recurrent myocardial infarction, and target vessel revascularization were recorded. Among 190 patients, 37 patients (19%) had positive T wave and 153 patients (81%) had negative T wave in lead aVR. Patients with positive T wave had higher rate of left main disease defined as stenosis ≥50% (11% vs. 2%, p = .028) than those with negative T wave. Patients with positive T wave had higher rate of 1-year MACE (38% vs. 13%, p < .001) driven by higher all-cause mortality (27% vs. 5%, p < .001). Positive T wave was an independent predictor for 1-year MACE (OR 2.74; 95% CI 1.04-7.15; p = .04). Positive T wave in lead aVR was an independent predictor for 1-year MACE in patients with first anterior wall STEMI. © 2017 Wiley Periodicals, Inc.

  10. Frequency of Inverted Electrocardiographic T Waves (Cerebral T Waves) in Patients With Acute Strokes and Their Relation to Left Ventricular Wall Motion Abnormalities.

    PubMed

    Stone, Jeremy; Mor-Avi, Victor; Ardelt, Agnieszka; Lang, Roberto M

    2018-01-01

    Transient, symmetric, and deep inverted electrocardiogram (ECG) T waves in the setting of stroke, commonly referred to as cerebral T waves, are rare, and the underlying mechanism is unclear. Our study aimed to test the hypothesis that cerebral T waves are associated with transient cardiac dysfunction. This retrospective study included 800 patients admitted with the primary diagnosis of hemorrhagic or ischemic stroke. ECGs were examined for cerebral T waves, defined as T-wave inversion of ≥5 mm depth in ≥4 contiguous precordial leads. Echocardiograms of those meeting these criteria were examined for the presence of left ventricular (LV) wall motion abnormalities. Follow-up evaluation included both ECG and echocardiogram. Of the 800 patients, 17 had cerebral T waves on ECG (2.1%). All 17 patients had ischemic strokes, of which 11 were in the middle cerebral artery distribution (65%), and 2 were cerebellar (12%), whereas the remaining 4 involved other locations. Follow-up ECG showed resolution of the T-wave changes in all 17 patients. Of these patients, 14 (82%) had normal wall motion, and 3 had transient wall motion abnormalities (18%). Two of these patients had Takotsubo-like cardiomyopathy with apical ballooning, and the third had globally reduced LV function. Coronary angiography showed no significant disease to explain the LV dysfunction. In summary, in our cohort of patients with acute stroke, cerebral T waves were rare and occurred only in ischemic stroke. Eighteen percent of patients with cerebral T waves had significant transient wall motion abnormalities. Patients with stroke with cerebral T waves, especially in those with ischemic strokes, should be assessed for cardiac dysfunction. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Defibrillator synchronization tester.

    PubMed

    Demirbilek, Fatma N; Krajnak, Mike; Stolarczyk, George

    2009-01-01

    A defibrillator sync output signal connector provides an ECG synchronization signal that can be used by some defibrillators for the purpose of performing synchronized cardioversion [1]. This process is used to stop an abnormally fast heart rate or cardiac arrhythmia by the delivery of a therapeutic dose of electric current to the heart during the R-wave of the cardiac cycle. Timing the shock to the R-wave prevents the delivery of the shock during the vulnerable period of the cardiac cycle, which could induce ventricular fibrillation [2]. GE patient monitors include a selectable analog output feature, which provides an analog ECG or arterial blood pressure signal. The blood pressure signal can be used to synchronize balloon pumps to provide cardiac assist to post-MI patients with poor injection fraction. Proper operation requires the defibrillator sync and analog output function to be checked. Checkouts are typically done during planned maintenance and after major part replacements such as patient monitor's main CPU board. Checking out defibrillator sync signals could be done using a GE defibrillator sync tester. The defibrillator sync tester provides a loop back path for the defibrillator sync signals to be displayed on the patient monitor screen and eliminates the need for an external oscilloscope.

  12. Use of wave intensity analysis of carotid arteries in identifying and monitoring left ventricular systolic function dynamics in rabbits.

    PubMed

    Zhang, Hui; Zheng, Rongqin; Qian, Xiaoxian; Zhang, Chengxi; Hao, Baoshun; Huang, Zeping; Wu, Tao

    2014-03-01

    Wave intensity analysis (WIA) of the carotid artery was conducted to determine the changes that occur in left ventricular systolic function after administration of doxorubicin in rabbits. Each randomly selected rabbit was subject to routine ultrasound, WIA of the carotid artery, cardiac catheterization and pathologic examination every week and was followed for 16 wk. The first positive peak (WI1) of the carotid artery revealed that left ventricular systolic dysfunction occurred earlier than conventional indexes of heart function. WI1 was highly, positively correlated with the maximum rate of rise in left ventricular pressure in cardiac catheterization (r = 0.94, p < 0.01) and moderately negatively correlated with the apoptosis index of myocardial cells, an indicator of myocardial damage (r = -0.69, p < 0.01). Ultrasound WIA of the carotid artery sensitively reflects early myocardial damage and cardiac function, and the result is highly consistent with cardiac catheterization findings and the apoptosis index of myocardial cells. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  13. Quantitative assessment of brain tissue oxygenation in porcine models of cardiac arrest and cardiopulmonary resuscitation using hyperspectral near-infrared spectroscopy

    NASA Astrophysics Data System (ADS)

    Lotfabadi, Shahin S.; Toronov, Vladislav; Ramadeen, Andrew; Hu, Xudong; Kim, Siwook; Dorian, Paul; Hare, Gregory M. T.

    2014-03-01

    Near-infrared spectroscopy (NIRS) is a non-invasive tool to measure real-time tissue oxygenation in the brain. In an invasive animal experiment we were able to directly compare non-invasive NIRS measurements on the skull with invasive measurements directly on the brain dura matter. We used a broad-band, continuous-wave hyper-spectral approach to measure tissue oxygenation in the brain of pigs under the conditions of cardiac arrest, cardiopulmonary resuscitation (CPR), and defibrillation. An additional purpose of this research was to find a correlation between mortality due to cardiac arrest and inadequacy of the tissue perfusion during attempts at resuscitation. Using this technique we measured the changes in concentrations of oxy-hemoglobin [HbO2] and deoxy-hemoglobin [HHb] to quantify the tissue oxygenation in the brain. We also extracted cytochrome c oxidase changes Δ[Cyt-Ox] under the same conditions to determine increase or decrease in cerebral oxygen delivery. In this paper we proved that applying CPR, [HbO2] concentration and tissue oxygenation in the brain increase while [HHb] concentration decreases which was not possible using other measurement techniques. We also discovered a similar trend in changes of both [Cyt-Ox] concentration and tissue oxygen saturation (StO2). Both invasive and non-invasive measurements showed similar results.

  14. Spatial nonuniformity of excitation-contraction coupling causes arrhythmogenic Ca2+ waves in rat cardiac muscle.

    PubMed

    Wakayama, Yuji; Miura, Masahito; Stuyvers, Bruno D; Boyden, Penelope A; ter Keurs, Henk E D J

    2005-06-24

    Ca2+ waves underlying triggered propagated contractions (TPCs) are initiated in damaged regions in cardiac muscle and cause arrhythmias. We studied Ca2+ waves underlying TPCs in rat cardiac trabeculae under experimental conditions that simulate the functional nonuniformity caused by local mechanical or ischemic local damage of myocardium. A mechanical discontinuity along the trabeculae was created by exposing the preparation to a small jet of solution with a composition that reduces excitation-contraction coupling (ECC) in myocytes within that segment. The jet solution contained either caffeine (5 mmol/L), 2,3-butanedione monoxime (BDM; 20 mmol/L), or low Ca2+ concentration ([Ca2+]; 0.2 mmol/L). Force was measured with a silicon strain gauge and sarcomere length with laser diffraction techniques in 15 trabeculae. Simultaneously, [Ca2+]i was measured locally using epifluorescence of Fura-2. The jet of solution was applied perpendicularly to a small muscle region (200 to 300 microm) at constant flow. When the jet contained caffeine, BDM, or low [Ca2+], during the stimulated twitch, muscle-twitch force decreased and the sarcomeres in the exposed segment were stretched by shortening normal regions outside the jet. Typical protocols for TPC induction (7.5 s-2.5 Hz stimulus trains at 23 degrees C; [Ca2+]o=2.0 mmol/L) reproducibly generated Ca2+ waves that arose from the border between shortening and stretched regions. Such Ca2+ waves started during force-relaxation of the last stimulated twitch of the train and propagated (0.2 to 2.8 mm/sec) into segments both inside and outside of the jet. Arrhythmias, in the form of nondriven rhythmic activity, were induced when the amplitude of the Ca2+-wave was increased by raising [Ca2+]o. Arrhythmias disappeared rapidly when uniformity of ECC throughout the muscle was restored by turning the jet off. These results show, for the first time, that nonuniform ECC can cause Ca2+ waves underlying TPCs and suggest that Ca2+ dissociated from myofilaments plays an important role in the initiation of Ca2+ waves.

  15. Spiral-Wave Dynamics in a Mathematical Model of Human Ventricular Tissue with Myocytes and Fibroblasts

    PubMed Central

    Nayak, Alok Ranjan; Shajahan, T. K.; Panfilov, A. V.; Pandit, Rahul

    2013-01-01

    Cardiac fibroblasts, when coupled functionally with myocytes, can modulate the electrophysiological properties of cardiac tissue. We present systematic numerical studies of such modulation of electrophysiological properties in mathematical models for (a) single myocyte-fibroblast (MF) units and (b) two-dimensional (2D) arrays of such units; our models build on earlier ones and allow for zero-, one-, and two-sided MF couplings. Our studies of MF units elucidate the dependence of the action-potential (AP) morphology on parameters such as , the fibroblast resting-membrane potential, the fibroblast conductance , and the MF gap-junctional coupling . Furthermore, we find that our MF composite can show autorhythmic and oscillatory behaviors in addition to an excitable response. Our 2D studies use (a) both homogeneous and inhomogeneous distributions of fibroblasts, (b) various ranges for parameters such as , and , and (c) intercellular couplings that can be zero-sided, one-sided, and two-sided connections of fibroblasts with myocytes. We show, in particular, that the plane-wave conduction velocity decreases as a function of , for zero-sided and one-sided couplings; however, for two-sided coupling, decreases initially and then increases as a function of , and, eventually, we observe that conduction failure occurs for low values of . In our homogeneous studies, we find that the rotation speed and stability of a spiral wave can be controlled either by controlling or . Our studies with fibroblast inhomogeneities show that a spiral wave can get anchored to a local fibroblast inhomogeneity. We also study the efficacy of a low-amplitude control scheme, which has been suggested for the control of spiral-wave turbulence in mathematical models for cardiac tissue, in our MF model both with and without heterogeneities. PMID:24023798

  16. Clinical significance of J-wave in elite athletes.

    PubMed

    Pelliccia, Antonio; Quattrini, Filippo M

    2015-01-01

    The J-wave pattern on 12-lead ECG is traditionally defined as a positive deflection at junction between the end of the QRS and the beginning of the ST-segment. This pattern has recently been associated with increased risk for idiopathic ventricular fibrillation in the absence of cardiovascular disease. The interest for the clinical significance of J-wave pattern as a potential ECG hallmark of high risk for cardiac arrest has recently been reinforced by the growing practice of ECG screening, such as occurs in large population of young competitive athletes. The available scientific evidence shows that the J-wave pattern is relatively common in trained athletes (ranging from 14% to 44%) and, differently from subjects who suffered from ventricular fibrillation, commonly localized in lateral leads while it is relatively rare to be found in inferior leads. Furthermore the J-wave pattern has been demonstrated to be a dynamic phenomenon related to the training status, with the larger prominence at the peak of training and with an inverse relation between magnitude of J-wave and heart rate. In addition the J-wave pattern is usually associated with other ECG changes, such as increased QRS voltages and ST-segment elevation, as well as LV remodeling, suggesting that it likely represents another expression of the physiologic athlete's heart. Finally the scientific data available demonstrated that during a medium follow-up period the J-wave pattern does not convey risk for adverse cardiac events, including sudden death or ventricular tachyarrhythmias. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Alternans and Spiral Breakup in an Excitable Reaction-Diffusion System: A Simulation Study

    PubMed Central

    Gani, M. Osman; Ogawa, Toshiyuki

    2014-01-01

    The determination of the mechanisms of spiral breakup in excitable media is still an open problem for researchers. In the context of cardiac electrophysiological activities, spiral breakup exhibits complex spatiotemporal pattern known as ventricular fibrillation. The latter is the major cause of sudden cardiac deaths all over the world. In this paper, we numerically study the instability of periodic planar traveling wave solution in two dimensions. The emergence of stable spiral pattern is observed in the considered model. This pattern occurs when the heart is malfunctioning (i.e., ventricular tachycardia). We show that the spiral wave breakup is a consequence of the transverse instability of the planar traveling wave solutions. The alternans, that is, the oscillation of pulse widths, is observed in our simulation results. Moreover, we calculate the widths of spiral pulses numerically and observe that the stable spiral pattern bifurcates to an oscillatory wave pattern in a one-parameter family of solutions. The spiral breakup occurs far below the bifurcation when the maximum and the minimum excited states become more distinct, and hence the alternans becomes more pronounced. PMID:27379274

  18. Alternans and Spiral Breakup in an Excitable Reaction-Diffusion System: A Simulation Study.

    PubMed

    Gani, M Osman; Ogawa, Toshiyuki

    2014-01-01

    The determination of the mechanisms of spiral breakup in excitable media is still an open problem for researchers. In the context of cardiac electrophysiological activities, spiral breakup exhibits complex spatiotemporal pattern known as ventricular fibrillation. The latter is the major cause of sudden cardiac deaths all over the world. In this paper, we numerically study the instability of periodic planar traveling wave solution in two dimensions. The emergence of stable spiral pattern is observed in the considered model. This pattern occurs when the heart is malfunctioning (i.e., ventricular tachycardia). We show that the spiral wave breakup is a consequence of the transverse instability of the planar traveling wave solutions. The alternans, that is, the oscillation of pulse widths, is observed in our simulation results. Moreover, we calculate the widths of spiral pulses numerically and observe that the stable spiral pattern bifurcates to an oscillatory wave pattern in a one-parameter family of solutions. The spiral breakup occurs far below the bifurcation when the maximum and the minimum excited states become more distinct, and hence the alternans becomes more pronounced.

  19. Modelling far field pacing for terminating spiral waves pinned to ischaemic heterogeneities in cardiac tissue

    PubMed Central

    Boccia, E.; Luther, S.

    2017-01-01

    In cardiac tissue, electrical spiral waves pinned to a heterogeneity can be unpinned (and eventually terminated) using electric far field pulses and recruiting the heterogeneity as a virtual electrode. While for isotropic media the process of unpinning is much better understood, the case of an anisotropic substrate with different conductivities in different directions still needs intensive investigation. To study the impact of anisotropy on the unpinning process, we present numerical simulations based on the bidomain formulation of the phase I of the Luo and Rudy action potential model modified due to the occurrence of acute myocardial ischaemia. Simulating a rotating spiral wave pinned to an ischaemic heterogeneity, we compare the success of sequences of far field pulses in the isotropic and the anisotropic case for spirals still in transient or in steady rotation states. Our results clearly indicate that the range of pacing parameters resulting in successful termination of pinned spiral waves is larger in anisotropic tissue than in an isotropic medium. This article is part of the themed issue ‘Mathematical methods in medicine: neuroscience, cardiology and pathology’. PMID:28507234

  20. Intra-QT spectral coherence as a possible noninvasive marker of sustained ventricular tachycardia.

    PubMed

    Piccirillo, Gianfranco; Moscucci, Federica; Persi, Alessandro; Di Barba, Daniele; Pappadà, Maria Antonella; Rossi, Pietro; Quaglione, Raffaele; Nguyen, Bich Lien; Barillà, Francesco; Casenghi, Matteo; Magrì, Damiano

    2014-01-01

    Sudden cardiac death is the main cause of mortality in patients affected by chronic heart failure (CHF) and with history of myocardial infarction. No study yet investigated the intra-QT phase spectral coherence as a possible tool in stratifying the arrhythmic susceptibility in patients at risk of sudden cardiac death (SCD). We, therefore, assessed possible difference in spectral coherence between the ECG segment extending from the q wave to the T wave peak (QTp) and the one from T wave peak to the T wave end (Te) between patients with and without Holter ECG-documented sustained ventricular tachycardia (VT). None of the QT variability indexes as well as most of the coherences and RR power spectral variables significantly differed between the two groups except for the QTp-Te spectral coherence. The latter was significantly lower in patients with sustained VT than in those without (0.508 ± 0.150 versus 0.607 ± 0.150, P < 0.05). Although the responsible mechanism remains conjectural, the QTp-Te spectral coherence holds promise as a noninvasive marker predicting malignant ventricular arrhythmias.

  1. Intra-QT Spectral Coherence as a Possible Noninvasive Marker of Sustained Ventricular Tachycardia

    PubMed Central

    Piccirillo, Gianfranco; Moscucci, Federica; Di Barba, Daniele; Pappadà, Maria Antonella; Rossi, Pietro; Quaglione, Raffaele; Barillà, Francesco; Magrì, Damiano

    2014-01-01

    Sudden cardiac death is the main cause of mortality in patients affected by chronic heart failure (CHF) and with history of myocardial infarction. No study yet investigated the intra-QT phase spectral coherence as a possible tool in stratifying the arrhythmic susceptibility in patients at risk of sudden cardiac death (SCD). We, therefore, assessed possible difference in spectral coherence between the ECG segment extending from the q wave to the T wave peak (QTp) and the one from T wave peak to the T wave end (T e) between patients with and without Holter ECG-documented sustained ventricular tachycardia (VT). None of the QT variability indexes as well as most of the coherences and RR power spectral variables significantly differed between the two groups except for the QTp-T e spectral coherence. The latter was significantly lower in patients with sustained VT than in those without (0.508 ± 0.150 versus 0.607 ± 0.150, P < 0.05). Although the responsible mechanism remains conjectural, the QTp-T e spectral coherence holds promise as a noninvasive marker predicting malignant ventricular arrhythmias. PMID:25133170

  2. Modelling far field pacing for terminating spiral waves pinned to ischaemic heterogeneities in cardiac tissue

    NASA Astrophysics Data System (ADS)

    Boccia, E.; Luther, S.; Parlitz, U.

    2017-05-01

    In cardiac tissue, electrical spiral waves pinned to a heterogeneity can be unpinned (and eventually terminated) using electric far field pulses and recruiting the heterogeneity as a virtual electrode. While for isotropic media the process of unpinning is much better understood, the case of an anisotropic substrate with different conductivities in different directions still needs intensive investigation. To study the impact of anisotropy on the unpinning process, we present numerical simulations based on the bidomain formulation of the phase I of the Luo and Rudy action potential model modified due to the occurrence of acute myocardial ischaemia. Simulating a rotating spiral wave pinned to an ischaemic heterogeneity, we compare the success of sequences of far field pulses in the isotropic and the anisotropic case for spirals still in transient or in steady rotation states. Our results clearly indicate that the range of pacing parameters resulting in successful termination of pinned spiral waves is larger in anisotropic tissue than in an isotropic medium. This article is part of the themed issue `Mathematical methods in medicine: neuroscience, cardiology and pathology'.

  3. Cardiac MRI-confirmed mesalamine-induced myocarditis.

    PubMed

    Baker, William L; Saulsberry, Whitney J; Elliott, Kaitlyn; Parker, Matthew W

    2015-09-04

    A 38-year-old Caucasian man with a medical history significant for inflammatory bowel disease (IBD) and mesalamine use presented to the emergency department with stabbing, pleuritic, substernal chest pain over the previous 2 days. Findings of leucocytosis, elevated cardiac enzymes and inflammatory markers, T-wave or ST-segment abnormalities and left ventricular systolic dysfunction suggested mesalamine-induced myocarditis. However, a cardiac MRI confirmed the diagnosis. Signs and symptoms improved within days of withdrawal of mesalamine, and initiation of corticosteroids and follow-up studies within the next year were unremarkable. Importantly, the diagnosis of mesalamine-induced myocarditis confirmed via cardiac MRI is a step rarely performed in published cases. 2015 BMJ Publishing Group Ltd.

  4. Left ventricular ejection time, not heart rate, is an independent correlate of aortic pulse wave velocity.

    PubMed

    Salvi, Paolo; Palombo, Carlo; Salvi, Giovanni Matteo; Labat, Carlos; Parati, Gianfranco; Benetos, Athanase

    2013-12-01

    Several studies showed a positive association between heart rate and pulse wave velocity, a sensitive marker of arterial stiffness. However, no study involving a large population has specifically addressed the dependence of pulse wave velocity on different components of the cardiac cycle. The aim of this study was to explore in subjects of different age the link between pulse wave velocity with heart period (the reciprocal of heart rate) and the temporal components of the cardiac cycle such as left ventricular ejection time and diastolic time. Carotid-femoral pulse wave velocity was assessed in 3,020 untreated subjects (1,107 men). Heart period, left ventricular ejection time, diastolic time, and early-systolic dP/dt were determined by carotid pulse wave analysis with high-fidelity applanation tonometry. An inverse association was found between pulse wave velocity and left ventricular ejection time at all ages (<25 years, r(2) = 0.043; 25-44 years, r(2) = 0.103; 45-64 years, r(2) = 0.079; 65-84 years, r(2) = 0.044; ≥ 85 years, r(2) = 0.022; P < 0.0001 for all). A significant (P < 0.0001) negative but always weaker correlation between pulse wave velocity and heart period was also found, with the exception of the youngest subjects (P = 0.20). A significant positive correlation was also found between pulse wave velocity and dP/dt (P < 0.0001). With multiple stepwise regression analysis, left ventricular ejection time and dP/dt remained the only determinant of pulse wave velocity at all ages, whereas the contribution of heart period no longer became significant. Our data demonstrate that pulse wave velocity is more closely related to left ventricular systolic function than to heart period. This may have methodological and pathophysiological implications.

  5. [Experimental therapy of cardiac remodeling with quercetin-containing drugs].

    PubMed

    Kuzmenko, M A; Pavlyuchenko, V B; Tumanovskaya, L V; Dosenko, V E; Moybenko, A A

    2013-01-01

    It was shown that continuous beta-adrenergic hyperstimulation resulted in cardiac function disturbances and fibrosis of cardiac tissue. Treatment with quercetin-containing drugs, particularly, water-soluble corvitin and tableted quertin exerted favourable effect on cardiac hemodynamics, normalized systolic and diastolic function in cardiac remodeling, induced by sustained beta-adrenergic stimulation. It was estimated that conducted experimental therapy limited cardiac fibrosis area almost three-fold, that could be associated with first and foremost improved cardiac distensibility, characteristics of diastolic and also pump function in cardiac remodeling.

  6. Clinical safety of the ProMRI pacemaker system in patients subjected to thoracic spine and cardiac 1.5-T magnetic resonance imaging scanning conditions.

    PubMed

    Bailey, William M; Mazur, Alexander; McCotter, Craig; Woodard, Pamela K; Rosenthal, Lawrence; Johnson, Whitney; Mela, Theofanie

    2016-02-01

    Permanent cardiac pacemakers have historically been considered a contraindication to magnetic resonance imaging (MRI). The purpose of the ProMRI Phase B Study, a multicenter, prospective, single-arm, nonrandomized study, was to evaluate the clinical safety of the Biotronik ProMRI pacemaker system in patients undergoing thoracic spine and cardiac MRI. The ProMRI Phase B study enrolled 245 patients with stable baseline pacing indices implanted with an Entovis pacemaker (DR-T or SR-T) and Setrox 53-cm and/or 60-cm lead(s). Device interrogation was performed at enrollment, pre- and post-MRI scan, and 1 and 3 months post-MRI. End-points were (1) freedom from MRI- and pacing system-related serious adverse device effects through 1 month post-MRI; (2) freedom from atrial and ventricular MRI-induced pacing threshold increase (>0.5 V); and (3) freedom from P- and R-wave amplitude attenuation (<50%), or P wave <1.5 mV, or R wave <5.0 mV at 1 month post-MRI. In total, 216 patients completed the MRI and 1-month post-MRI follow-up. One adverse event possibly related to the implanted system and the MRI procedure occurred, resulting in a serious adverse device effect-free rate of 99.6% (220/221; P < .0001. Freedom from atrial and ventricular pacing threshold increase was 100% (194/194, P < .001) and 100% (206/206, P < .001) respectively. Freedom from P- and R-wave amplitude attenuation was 98.2% (167/170, P < .001) and 100% (188/188, P < .001) respectively. The results of the ProMRI Phase B study demonstrate the clinical safety and efficacy of the ProMRI pacemaker system in patients subjected to thoracic spine and cardiac MRI conditions. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  7. Are 12-lead ECG findings associated with the risk of cardiovascular events after ischemic stroke in young adults?

    PubMed

    Pirinen, Jani; Putaala, Jukka; Aarnio, Karoliina; Aro, Aapo L; Sinisalo, Juha; Kaste, Markku; Haapaniemi, Elena; Tatlisumak, Turgut; Lehto, Mika

    2016-11-01

    Ischemic stroke (IS) in a young patient is a disaster and recurrent cardiovascular events could add further impairment. Identifying patients with high risk of such events is therefore important. The prognostic relevance of ECG for this population is unknown. A total of 690 IS patients aged 15-49 years were included. A 12-lead ECG was obtained 1-14 d after the onset of stroke. We adjusted for demographic factors, comorbidities, and stroke characteristics, Cox regression models were used to identify independent ECG parameters associated with long-term risks of (1) any cardiovascular event, (2) cardiac events, and (3) recurrent stroke. Median follow-up time was 8.8 years. About 26.4% of patients experienced a cardiovascular event, 14.5% had cardiac events, and 14.6% recurrent strokes. ECG parameters associated with recurrent cardiovascular events were bundle branch blocks, P-terminal force, left ventricular hypertrophy, and a broader QRS complex. Furthermore, more leftward P-wave axis, prolonged QTc, and P-wave duration >120 ms were associated with increased risks of cardiac events. No ECG parameters were independently associated with recurrent stroke. A 12-lead ECG can be used for risk prediction of cardiovascular events but not for recurrent stroke in young IS patients. KEY MESSAGES ECG is an easy, inexpensive, and useful tool for identifying young ischemic stroke patients with a high risk for recurrent cardiovascular events and it has a statistically significant association with these events even after adjusting for confounding factors. Bundle branch blocks, P-terminal force, broader QRS complex, LVH according to Cornell voltage duration criteria, more leftward P-wave axis, prolonged QTc, and P-wave duration >120 ms are predictors for future cardiovascular or cardiac events in these patients. No ECG parameters were independently associated with recurrent stroke.

  8. Improved pressure contour analysis for estimating cardiac stroke volume using pulse wave velocity measurement.

    PubMed

    Kamoi, Shun; Pretty, Christopher; Balmer, Joel; Davidson, Shaun; Pironet, Antoine; Desaive, Thomas; Shaw, Geoffrey M; Chase, J Geoffrey

    2017-04-24

    Pressure contour analysis is commonly used to estimate cardiac performance for patients suffering from cardiovascular dysfunction in the intensive care unit. However, the existing techniques for continuous estimation of stroke volume (SV) from pressure measurement can be unreliable during hemodynamic instability, which is inevitable for patients requiring significant treatment. For this reason, pressure contour methods must be improved to capture changes in vascular properties and thus provide accurate conversion from pressure to flow. This paper presents a novel pressure contour method utilizing pulse wave velocity (PWV) measurement to capture vascular properties. A three-element Windkessel model combined with the reservoir-wave concept are used to decompose the pressure contour into components related to storage and flow. The model parameters are identified beat-to-beat from the water-hammer equation using measured PWV, wave component of the pressure, and an estimate of subject-specific aortic dimension. SV is then calculated by converting pressure to flow using identified model parameters. The accuracy of this novel method is investigated using data from porcine experiments (N = 4 Pietrain pigs, 20-24.5 kg), where hemodynamic properties were significantly altered using dobutamine, fluid administration, and mechanical ventilation. In the experiment, left ventricular volume was measured using admittance catheter, and aortic pressure waveforms were measured at two locations, the aortic arch and abdominal aorta. Bland-Altman analysis comparing gold-standard SV measured by the admittance catheter and estimated SV from the novel method showed average limits of agreement of ±26% across significant hemodynamic alterations. This result shows the method is capable of estimating clinically acceptable absolute SV values according to Critchely and Critchely. The novel pressure contour method presented can accurately estimate and track SV even when hemodynamic properties are significantly altered. Integrating PWV measurements into pressure contour analysis improves identification of beat-to-beat changes in Windkessel model parameters, and thus, provides accurate estimate of blood flow from measured pressure contour. The method has great potential for overcoming weaknesses associated with current pressure contour methods for estimating SV.

  9. Risk of Cardiac Rhythm Problems During Spaceflight

    NASA Technical Reports Server (NTRS)

    Lee, Stuart M. C.; Stenger, Michael B.; Laurie, Steven S.; Macias, Brandon R.

    2017-01-01

    NASA has concerns regarding the incidence and clinical significance of cardiac arrhythmias that could occur during long-term exposure to the spaceflight environment, such as on the International Space Station (ISS) or during a prolonged (e.g., up to 3 years) sojourn to Mars or on the Moon. There have been some anecdotal reports and a few documented cases of cardiac arrhythmias in space, including one documented episode of non-sustained ventricular tachycardia. The potential catastrophic nature of a sudden cardiac death in the remote space environment has led to concerns from the early days of the space program that spaceflight might be arrhythmogenic. Indeed, there are known and well-defined changes in the cardiovascular system with spaceflight: a) plasma volume is reduced, b) left ventricular mass is decreased, and c) the autonomic nervous system adapts to the weightless environment. Combined, these physiologic adaptations suggest that changes in cardiac structure and neuro-humoral environment during spaceflight could alter electrical conduction, although the evidence supporting this contention consists mostly of minor changes in QT interval (the time between the start of the Q wave and the end of the T wave on an electrocardiogram tracing) in a small number of astronauts after long-duration spaceflight. Concurrent with efforts by NASA Medical Operations to refine and improve screening techniques relevant to arrhythmias and cardiovascular disease, as NASA enters the era of exploration-class missions it will be critical to determine with the highest degree of certainty whether spaceflight by itself alters cardiac structure and function sufficiently to increase the risk of arrhythmias.

  10. Physiome-model-based state-space framework for cardiac deformation recovery.

    PubMed

    Wong, Ken C L; Zhang, Heye; Liu, Huafeng; Shi, Pengcheng

    2007-11-01

    To more reliably recover cardiac information from noise-corrupted, patient-specific measurements, it is essential to employ meaningful constraining models and adopt appropriate optimization criteria to couple the models with the measurements. Although biomechanical models have been extensively used for myocardial motion recovery with encouraging results, the passive nature of such constraints limits their ability to fully count for the deformation caused by active forces of the myocytes. To overcome such limitations, we propose to adopt a cardiac physiome model as the prior constraint for cardiac motion analysis. The cardiac physiome model comprises an electric wave propagation model, an electromechanical coupling model, and a biomechanical model, which are connected through a cardiac system dynamics for a more complete description of the macroscopic cardiac physiology. Embedded within a multiframe state-space framework, the uncertainties of the model and the patient's measurements are systematically dealt with to arrive at optimal cardiac kinematic estimates and possibly beyond. Experiments have been conducted to compare our proposed cardiac-physiome-model-based framework with the solely biomechanical model-based framework. The results show that our proposed framework recovers more accurate cardiac deformation from synthetic data and obtains more sensible estimates from real magnetic resonance image sequences. With the active components introduced by the cardiac physiome model, cardiac deformations recovered from patient's medical images are more physiologically plausible.

  11. Teaching Cardiac Electrophysiology Modeling to Undergraduate Students: Laboratory Exercises and GPU Programming for the Study of Arrhythmias and Spiral Wave Dynamics

    ERIC Educational Resources Information Center

    Bartocci, Ezio; Singh, Rupinder; von Stein, Frederick B.; Amedome, Avessie; Caceres, Alan Joseph J.; Castillo, Juan; Closser, Evan; Deards, Gabriel; Goltsev, Andriy; Ines, Roumwelle Sta.; Isbilir, Cem; Marc, Joan K.; Moore, Diquan; Pardi, Dana; Sadhu, Sandeep; Sanchez, Samuel; Sharma, Pooja; Singh, Anoopa; Rogers, Joshua; Wolinetz, Aron; Grosso-Applewhite, Terri; Zhao, Kai; Filipski, Andrew B.; Gilmour, Robert F., Jr.; Grosu, Radu; Glimm, James; Smolka, Scott A.; Cherry, Elizabeth M.; Clarke, Edmund M.; Griffeth, Nancy; Fenton, Flavio H.

    2011-01-01

    As part of a 3-wk intersession workshop funded by a National Science Foundation Expeditions in Computing award, 15 undergraduate students from the City University of New York collaborated on a study aimed at characterizing the voltage dynamics and arrhythmogenic behavior of cardiac cells for a broad range of physiologically relevant conditions…

  12. Effects of High-Intensity Interval Training on Aerobic Capacity in Cardiac Patients: A Systematic Review with Meta-Analysis

    PubMed Central

    Xie, Bin; Yan, Xianfeng

    2017-01-01

    Purpose. The aim of this study was to compare the effects of high-intensity interval training (INTERVAL) and moderate-intensity continuous training (CONTINUOUS) on aerobic capacity in cardiac patients. Methods. A meta-analysis identified by searching the PubMed, Cochrane Library, EMBASE, and Web of Science databases from inception through December 2016 compared the effects of INTERVAL and CONTINUOUS among cardiac patients. Results. Twenty-one studies involving 736 participants with cardiac diseases were included. Compared with CONTINUOUS, INTERVAL was associated with greater improvement in peak VO2 (mean difference 1.76 mL/kg/min, 95% confidence interval 1.06 to 2.46 mL/kg/min, p < 0.001) and VO2 at AT (mean difference 0.90 mL/kg/min, 95% confidence interval 0.0 to 1.72 mL/kg/min, p = 0.03). No significant difference between the INTERVAL and CONTINUOUS groups was observed in terms of peak heart rate, peak minute ventilation, VE/VCO2 slope and respiratory exchange ratio, body mass, systolic or diastolic blood pressure, triglyceride or low- or high-density lipoprotein cholesterol level, flow-mediated dilation, or left ventricular ejection fraction. Conclusions. This study showed that INTERVAL improves aerobic capacity more effectively than does CONTINUOUS in cardiac patients. Further studies with larger samples are needed to confirm our observations. PMID:28386556

  13. Feasibility of noninvasive fetal electrocardiographic monitoring in a clinical setting.

    PubMed

    Arya, Bhawna; Govindan, Rathinaswamy; Krishnan, Anita; Duplessis, Adre; Donofrio, Mary T

    2015-06-01

    Cardiac rhythm is an essential component of fetal cardiac evaluation. The Monica AN24 is a fetal heart rate monitor that may provide a quick, inexpensive modality for obtaining a noninvasive fetal electrocardiogram (fECG) in a clinical setting. The fECG device has the ability to acquire fECG signals and allow calculation of fetal cardiac time intervals between 16- and 42-week gestational age (GA). We aimed to demonstrate the feasibility of fECG acquisition in a busy fetal cardiology clinic using the Monica fetal heart rate monitor. This is a prospective observational pilot study of fECG acquired from fetuses referred for fetal echocardiography. Recordings were performed for 5-15 min. Maternal signals were attenuated and fECG averaged. fECG and fetal cardiac time intervals (PR, QRS, RR, and QT) were evaluated by two cardiologists independently and inter-observer reliability was assessed using intraclass coefficient (ICC). Sixty fECGs were collected from 50 mothers (mean GA 28.1 ± 6.1). Adequate signal-averaged waveforms were obtained in 20 studies with 259 cardiac cycles. Waveforms could not be obtained between 26 and 30 weeks. Fetal cardiac time intervals were measured and were reproducible for PR (ICC = 0.89; CI 0.77-0.94), QRS (ICC = 0.79; CI 0.51-0.91), and RR (ICC = 0.77; CI 0.53-0.88). QT ICC was poor due to suboptimal T-wave tracings. Acquisition of fECG and measurement of fetal cardiac time intervals is feasible in a clinical setting between 19- and 42-week GA, though tracings are difficult to obtain, especially between 26 and 30 weeks. There was high reliability in fetal cardiac time intervals measurements, except for QT. The device may be useful for assessing atrioventricular/intraventricular conduction in fetuses from 20 to 26 and >30 weeks. Techniques to improve signal acquisition, namely T-wave amplification, are ongoing.

  14. Cardiac sodium channel blockade after an intentional ingestion of lacosamide, cyclobenzaprine, and levetiracetam: Case report.

    PubMed

    Chua-Tuan, Jenny L; Cao, Dazhe; Iwanicki, Janetta L; Hoyte, Christopher O

    2015-07-01

    Lacosamide treats partial seizures by enhancing slow inactivation of voltage-gated sodium channels. The described cardiac toxicity of lacosamide in the literature to date includes atrioventricular blockade (PR prolongation), atrial flutter, atrial fibrillation, sinus pauses, ventricular tachycardia and a single cardiac arrest. We report a second case of cardiac arrest following an intentional lacosamide overdose. A 16 year-old female with a seizure disorder was found unresponsive in pulseless ventricular tachycardia after intentionally ingesting 4.5 g (76 mg/kg) lacosamide, 120 mg (2 mg/kg) cyclobenzaprine and an unknown amount of levetiracetam. Exact time of ingestion was unknown. Her initial electrocardiogram (ECG) demonstrated sinus tachycardia at 139 beats per minute, QRS duration 112 ms, and terminal R-wave in lead aVR > 3 mm. Despite treatment with 150 mEq of sodium bicarbonate, she had persistent EKG findings eight hours after presentation. Her serum lacosamide concentration nine hours after presentation was elevated at 22.8 μg/mL, while serum cyclobenzaprine concentration was 16 ng/mL (therapeutic: 10-30 ng/mL), and serum levetiracetam concentration was 22.7 μg/mL (therapeutic: 12-46 μg/mL). On hospital day three, ECG demonstrated resolution of the terminal R-wave with QRS of 78 ms. The patient recovered without physical or neurologic sequelae. The patient's lacosamide, cyclobenzaprine and levetiracetam overdose was associated with QRS prolongation and terminal right axis deviation--suggesting sodium channel blockade as a likely etiology for her cardiac arrest. Cyclobenzaprine has potential for sodium channel blockade and ventricular dysrhythmias although cardiac toxicity due to cyclobenzaprine alone is rare. The combination of cyclobenzaprine with lacosamide may have resulted in cardiovascular collapse. In conclusion, overdose of lacosamide combined with therapeutic concentrations of sodium channel blocking xenobiotics may cause cardiac conduction delays and cardiac arrest.

  15. In-hospital pediatric cardiac arrest in Spain.

    PubMed

    López-Herce, Jesús; del Castillo, Jimena; Cañadas, Sonia; Rodríguez-Núñez, Antonio; Carrillo, Angel

    2014-03-01

    The objective was to analyze the characteristics and prognostic factors of in-hospital pediatric cardiac arrest in Spain. A prospective observational study was performed to examine in-hospital pediatric cardiac arrest. Two hundred children were studied, aged between 1 month and 18 years, with in-hospital cardiac arrest. Univariate and multivariate logistic regression analyses were performed to assess the influence of each factor on survival to hospital discharge. Return of spontaneous circulation was achieved in 74% of the patients and 41% survived to hospital discharge. The survival rate was significantly higher than that reported in a previous Spanish study 10 years earlier (25.9%). In the univariate analysis, the factors related to mortality were body weight higher than 10 kg; continuous infusion of vasoactive drugs prior to cardiac arrest; sepsis and neurological disorders as causes of cardiac arrest, the need for treatment with adrenaline, bicarbonate, and volume expansion, and prolonged cardiopulmonary resuscitation. In the multivariate analysis, the factors related to mortality were hematologic/oncologic diseases, continuous infusion of vasoactive drugs prior to cardiac arrest, cardiopulmonary resuscitation for more than 20 min, and treatment with bicarbonate and volume expansion. Survival after in-hospital cardiac arrest in children has significantly improved in recent years. The factors related to in-hospital mortality were hematologic/oncologic diseases, continuous infusion of vasoactive drugs prior to cardiac arrest, the duration of cardiopulmonary resuscitation, and treatment with bicarbonate and volume expansion. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  16. Facilitation of cytosolic calcium wave propagation by local calcium uptake into the sarcoplasmic reticulum in cardiac myocytes.

    PubMed

    Maxwell, Joshua T; Blatter, Lothar A

    2012-12-01

    The widely accepted paradigm for cytosolic Ca(2+) wave propagation postulates a 'fire-diffuse-fire' mechanism where local Ca(2+)-induced Ca(2+) release (CICR) from the sarcoplasmic reticulum (SR) via ryanodine receptor (RyR) Ca(2+) release channels diffuses towards and activates neighbouring release sites, resulting in a propagating Ca(2+) wave. A recent challenge to this paradigm proposed the requirement for an intra-SR 'sensitization' Ca(2+) wave that precedes the cytosolic Ca(2+) wave and primes RyRs from the luminal side to CICR. Here, we tested this hypothesis experimentally with direct simultaneous measurements of cytosolic ([Ca(2+)](i); rhod-2) and intra-SR ([Ca(2+)](SR); fluo-5N) calcium signals during wave propagation in rabbit ventricular myocytes, using high resolution fluorescence confocal imaging. The increase in [Ca(2+)](i) at the wave front preceded depletion of the SR at each point along the calcium wave front, while during this latency period a transient increase of [Ca(2+)](SR) was observed. This transient elevation of [Ca(2+)](SR) could be identified at individual release junctions and depended on the activity of the sarco-endoplasmic reticulum Ca(2+)-ATPase (SERCA). Increased SERCA activity (β-adrenergic stimulation with 1 μM isoproterenol (isoprenaline)) decreased the latency period and increased the amplitude of the transient elevation of [Ca(2+)](SR), whereas inhibition of SERCA (3 μM cyclopiazonic acid) had the opposite effect. In conclusion, the data provide experimental evidence that local Ca(2+) uptake by SERCA into the SR facilitates the propagation of cytosolic Ca(2+) waves via luminal sensitization of the RyR, and supports a novel paradigm of a 'fire-diffuse-uptake-fire' mechanism for Ca(2+) wave propagation in cardiac myocytes.

  17. The prevalence, distribution, and clinical outcomes of electrocardiographic repolarization patterns in male athletes of African/Afro-Caribbean origin.

    PubMed

    Papadakis, Michael; Carre, Francois; Kervio, Gaelle; Rawlins, John; Panoulas, Vasileios F; Chandra, Navin; Basavarajaiah, Sandeep; Carby, Lorna; Fonseca, Tiago; Sharma, Sanjay

    2011-09-01

    Athletic training in male black athletes (BAs) is associated with marked ECG repolarization changes that overlap with hypertrophic cardiomyopathy (HCM). Differentiating between the two entities is prudent since BAs exhibit a higher prevalence of exercise-related sudden death from HCM compared with white athletes (WAs). Between 1996 and 2010, 904 BAs underwent serial cardiac evaluations including ECG and echocardiography. Athletes exhibiting T-wave inversions were investigated further for HCM. Results were compared with 1819 WAs, 119 black controls (BCs), and 52 black HCM patients. Athletes were followed up for 69.7 ± 29.6 months. T-wave inversions were present in 82.7% HCM patients, 22.8% BAs, 10.1% BCs, and 3.7% WAs. In athletes, the major determinant of T-wave inversions was black ethnicity. T-wave inversions in BAs (12.7%) were predominantly confined to contiguous anterior leads (V1-V4). Only 4.1% of BAs exhibited T-wave inversions in the lateral leads. In contrast, both BCs and HCM patients exhibited lower prevalence of T-wave inversions in leads V1-V4 (4.2 and 3.8%, respectively) with most T-wave inversions in HCM patients (76.9%) involving the lateral leads. During follow-up one BA survived cardiac arrest and two athletes (one BA, one WA) were diagnosed with HCM. All three exhibited T-wave inversions in the lateral leads. T-wave inversions in leads V1-V4 appear to represent an ethnic variant of 'athlete's heart'. Conversely, T-wave inversions in the lateral leads may represent the initial expression of underlying cardiomyopathy and merit further evaluation and regular surveillance.

  18. Mechano-electrical feedback explains T-wave morphology and optimizes cardiac pump function: insight from a multi-scale model.

    PubMed

    Hermeling, Evelien; Delhaas, Tammo; Prinzen, Frits W; Kuijpers, Nico H L

    2012-01-01

    In the ECG, T- and R-wave are concordant during normal sinus rhythm (SR), but discordant after a period of ventricular pacing (VP). Experiments showed that the latter phenomenon, called T-wave memory, is mediated by a mechanical stimulus. By means of a mathematical model, we investigated the hypothesis that slow acting mechano-electrical feedback (MEF) explains T-wave memory. In our model, electromechanical behavior of the left ventricle (LV) was simulated using a series of mechanically and electrically coupled segments. Each segment comprised ionic membrane currents, calcium handling, and excitation-contraction coupling. MEF was incorporated by locally adjusting conductivity of L-type calcium current (g(CaL)) to local external work. In our set-up, g(CaL) could vary up to 25%, 50%, 100% or unlimited amount around its default value. Four consecutive simulations were performed: normal SR (with MEF), acute VP, sustained VP (with MEF), and acutely restored SR. MEF led to T-wave concordance in normal SR and to discordant T-waves acutely after restoring SR. Simulated ECGs with a maximum of 25-50% adaptation closely resembled those during T-wave memory experiments in vivo and also provided the best compromise between optimal systolic and diastolic function. In conclusion, these simulation results indicate that slow acting MEF in the LV can explain a) the relatively small differences in systolic shortening and mechanical work during SR, b) the small dispersion in repolarization time, c) the concordant T-wave during SR, and d) T-wave memory. The physiological distribution in electrophysiological properties, reflected by the concordant T-wave, may serve to optimize cardiac pump function. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. Facilitation of cytosolic calcium wave propagation by local calcium uptake into the sarcoplasmic reticulum in cardiac myocytes

    PubMed Central

    Maxwell, Joshua T; Blatter, Lothar A

    2012-01-01

    The widely accepted paradigm for cytosolic Ca2+ wave propagation postulates a ‘fire-diffuse-fire’ mechanism where local Ca2+-induced Ca2+ release (CICR) from the sarcoplasmic reticulum (SR) via ryanodine receptor (RyR) Ca2+ release channels diffuses towards and activates neighbouring release sites, resulting in a propagating Ca2+ wave. A recent challenge to this paradigm proposed the requirement for an intra-SR ‘sensitization’ Ca2+ wave that precedes the cytosolic Ca2+ wave and primes RyRs from the luminal side to CICR. Here, we tested this hypothesis experimentally with direct simultaneous measurements of cytosolic ([Ca2+]i; rhod-2) and intra-SR ([Ca2+]SR; fluo-5N) calcium signals during wave propagation in rabbit ventricular myocytes, using high resolution fluorescence confocal imaging. The increase in [Ca2+]i at the wave front preceded depletion of the SR at each point along the calcium wave front, while during this latency period a transient increase of [Ca2+]SR was observed. This transient elevation of [Ca2+]SR could be identified at individual release junctions and depended on the activity of the sarco-endoplasmic reticulum Ca2+-ATPase (SERCA). Increased SERCA activity (β-adrenergic stimulation with 1 μm isoproterenol (isoprenaline)) decreased the latency period and increased the amplitude of the transient elevation of [Ca2+]SR, whereas inhibition of SERCA (3 μm cyclopiazonic acid) had the opposite effect. In conclusion, the data provide experimental evidence that local Ca2+ uptake by SERCA into the SR facilitates the propagation of cytosolic Ca2+ waves via luminal sensitization of the RyR, and supports a novel paradigm of a ‘fire-diffuse-uptake-fire’ mechanism for Ca2+ wave propagation in cardiac myocytes. PMID:22988145

  20. Transcatheter Replacement of Stenotic Aortic Valve Normalizes Cardiac-Coronary Interaction by Restoration of Systolic Coronary Flow Dynamics as Assessed by Wave Intensity Analysis.

    PubMed

    Rolandi, M Cristina; Wiegerinck, Esther M A; Casadonte, Lorena; Yong, Ze-Yie; Koch, Karel T; Vis, Marije; Piek, Jan J; Baan, Jan; Spaan, Jos A E; Siebes, Maria

    2016-04-01

    Aortic valve stenosis (AS) can cause angina despite unobstructed coronary arteries, which may be related to increased compression of the intramural microcirculation, especially at the subendocardium. We assessed coronary wave intensity and phasic flow velocity patterns to unravel changes in cardiac-coronary interaction because of transcatheter aortic valve implantation (TAVI). Intracoronary pressure and flow velocity were measured at rest and maximal hyperemia in undiseased vessels in 15 patients with AS before and after TAVI and in 12 control patients. Coronary flow reserve, systolic and diastolic velocity time integrals, and the energies of forward (aorta-originating) and backward (microcirculatory-originating) coronary waves were determined. Coronary flow reserve was 2.8±0.2 (mean±SEM) in control and 1.8±0.1 in AS (P<0.005) and was not restored by TAVI. Compared with control, the resting backward expansion wave was 45% higher in AS. The peak of the systolic forward compression wave was delayed in AS, consistent with a delayed peak aortic pressure, which was partially restored after TAVI. The energy of forward waves doubled after TAVI, whereas the backward expansion wave increased by >30%. The increase in forward compression wave with TAVI was related to an increase in systolic velocity time integral. AS or TAVI did not alter diastolic velocity time integral. Reduced coronary forward wave energy and systolic velocity time integral imply a compromised systolic flow velocity with AS that is restored after TAVI, suggesting an acute relief of excess compression in systole that likely benefits subendocardial perfusion. Vasodilation is observed to be a major determinant of backward waves. © 2016 American Heart Association, Inc.

  1. Changes in cardiac repolarisation during spontaneous nocturnal hypoglycaemia in subjects with type 1 diabetes: a preliminary report.

    PubMed

    Koivikko, Minna L; Kenttä, Tuomas; Salmela, Pasi I; Huikuri, Heikki V; Perkiömäki, Juha S

    2017-03-01

    Experimental studies have revealed that hypoglycaemia can result in morphological changes in electrocardiographic repolarisation in subjects with type 1 diabetes. However, the influence of spontaneous nocturnal hypoglycaemia on repolarisation morphology in a 'real life' situation is not clear. Adults with type 1 diabetes (n = 11) underwent continuous glucose monitoring with a subcutaneous sensor and digital 12-lead ECG recording for three nights. T-wave morphology was analysed with custom-made software during both hypoglycaemia (glucose <3.5 mmol/l at least 20 min) from ten consecutive heart beats in the middle of the deepest hypoglycaemia and from a control nonhypoglycaemic period (glucose ≥5.0 mmol/l) from the same recording. In the comparison of 10 hypoglycaemia-control pairs, heart rate (65 ± 12 beats/min during normoglycaemia versus 85 ± 19 beats/min during hypoglycaemia, p = 0.028) increased and the QT c interval (439 ± 5 vs. 373 ± 5 ms, respectively, p = 0.025) decreased significantly during hypoglycaemia. The spatial QRS-T angle (TCRT) was reduced, and the roughness of the T-wave loop (T-E) increased significantly (p = 0.037 for both) in the patients during hypoglycaemia. In adults with type 1 diabetes, spontaneous nocturnal hypoglycaemia results in morphological changes and increased heterogeneity of global cardiac repolarisation. These changes may contribute to the risk of 'dead in bed' syndrome encountered in young individuals with type 1 diabetes.

  2. Significance of deep T-wave inversions in asymptomatic athletes with normal cardiovascular examinations: practical solutions for managing the diagnostic conundrum

    PubMed Central

    Wilson, M G; Sharma, S; Carré, F; Charron, P; Richard, P; O'Hanlon, R; Prasad, S K; Heidbuchel, H; Brugada, J; Salah, O; Sheppard, M; George, K P; Whyte, G; Hamilton, B; Chalabi, H

    2012-01-01

    Preparticipation screening programmes for underlying cardiac pathologies are now commonplace for many international sporting organisations. However, providing medical clearance for an asymptomatic athlete without a family history of sudden cardiac death (SCD) is especially challenging when the athlete demonstrates particularly abnormal repolarisation patterns, highly suggestive of an inherited cardiomyopathy or channelopathy. Deep T-wave inversions of ≥2 contiguous anterior or lateral leads (but not aVR, and III) are of major concern for sports cardiologists who advise referring team physicians, as these ECG alterations are a recognised manifestation of hypertrophic cardiomyopathy (HCM) and arrhythmogenic right ventricular cardiomyopathy (ARVC). Subsequently, inverted T-waves may represent the first and only sign of an inherited heart muscle disease, in the absence of any other features and before structural changes in the heart can be detected. However, to date, there remains little evidence that deep T-wave inversions are always pathognomonic of either a cardiomyopathy or an ion channel disorder in an asymptomatic athlete following long-term follow-up. This paper aims to provide a systematic review of the prevalence of T-wave inversion in athletes and examine T-wave inversion and its relationship to structural heart disease, notably HCM and ARVC with a view to identify young athletes at risk of SCD during sport. Finally, the review proposes clinical management pathways (including genetic testing) for asymptomatic athletes demonstrating significant T-wave inversion with structurally normal hearts. PMID:23097480

  3. Significance of deep T-wave inversions in asymptomatic athletes with normal cardiovascular examinations: practical solutions for managing the diagnostic conundrum.

    PubMed

    Wilson, M G; Sharma, S; Carré, F; Charron, P; Richard, P; O'Hanlon, R; Prasad, S K; Heidbuchel, H; Brugada, J; Salah, O; Sheppard, M; George, K P; Whyte, G; Hamilton, B; Chalabi, H

    2012-11-01

    Preparticipation screening programmes for underlying cardiac pathologies are now commonplace for many international sporting organisations. However, providing medical clearance for an asymptomatic athlete without a family history of sudden cardiac death (SCD) is especially challenging when the athlete demonstrates particularly abnormal repolarisation patterns, highly suggestive of an inherited cardiomyopathy or channelopathy. Deep T-wave inversions of ≥ 2 contiguous anterior or lateral leads (but not aVR, and III) are of major concern for sports cardiologists who advise referring team physicians, as these ECG alterations are a recognised manifestation of hypertrophic cardiomyopathy (HCM) and arrhythmogenic right ventricular cardiomyopathy (ARVC). Subsequently, inverted T-waves may represent the first and only sign of an inherited heart muscle disease, in the absence of any other features and before structural changes in the heart can be detected. However, to date, there remains little evidence that deep T-wave inversions are always pathognomonic of either a cardiomyopathy or an ion channel disorder in an asymptomatic athlete following long-term follow-up. This paper aims to provide a systematic review of the prevalence of T-wave inversion in athletes and examine T-wave inversion and its relationship to structural heart disease, notably HCM and ARVC with a view to identify young athletes at risk of SCD during sport. Finally, the review proposes clinical management pathways (including genetic testing) for asymptomatic athletes demonstrating significant T-wave inversion with structurally normal hearts.

  4. Chasing the reflected wave back into the heart: a new hypothesis while the jury is still out

    PubMed Central

    Codreanu, Ion; Robson, Matthew D; Rider, Oliver J; Pegg, Tammy J; Jung, Bernd A; Dasanu, Constantin A; Clarke, Kieran; Holloway, Cameron J

    2011-01-01

    Background: Arterial stiffness directly influences cardiac function and is independently associated with cardiovascular risk. However, the influence of the aortic reflected pulse pressure wave on left ventricular function has not been well characterized. The aim of this study was to obtain detailed information on regional ventricular wall motion patterns corresponding to the propagation of the reflected aortic wave on ventricular segments. Methods: Left ventricular wall motion was investigated in a group of healthy volunteers (n = 14, age 23 ± 3 years), using cardiac magnetic resonance navigator-gated tissue phase mapping. The left ventricle was divided into 16 segments and regional wall motion was studied in high temporal detail. Results: Corresponding to the expected timing of the reflected aortic wave reaching the left ventricle, a characteristic “notch” of regional myocardial motion was seen in all radial, circumferential, and longitudinal velocity graphs. This notch was particularly prominent in septal segments adjacent to the left ventricular outflow tract on radial velocity graphs and in anterior and posterior left ventricular segments on circumferential velocity graphs. Similarly, longitudinal velocity graphs demonstrated a brief deceleration in the upward recoil motion of the entire ventricle at the beginning of diastole. Conclusion: These results provide new insights into the possible influence of the reflected aortic waves on ventricular segments. Although the association with the reflected wave appears to us to be unambiguous, it represents a novel research concept, and further studies enabling the actual recording of the pulse wave are required. PMID:21731888

  5. Differentiation of tumor from viable myocardium using cardiac tagging with MR imaging.

    PubMed

    Bouton, S; Yang, A; McCrindle, B W; Kidd, L; McVeigh, E R; Zerhouni, E A

    1991-01-01

    We report the application of myocardial tagging by MR to define tissue planes and differentiate contractile from noncontractile tissue in a neonate with congenital cardiac rhabdomyoma. Using custom-written pulse programming software, six 2 mm thick radiofrequency (RF) slice-selective presaturation pulses (tags) were used to label the chest wall and myocardium in a star pattern in diastole, approximately 60 ms before the R-wave gating trigger. This method successfully delineated the myocardium from noncontractile tumor, providing information that influenced clinical management. This RF tagging technique allowed us to confirm the exact intramyocardial location of a congenital cardiac tumor.

  6. Chaos for cardiac arrhythmias through a one-dimensional modulation equation for alternans

    PubMed Central

    Dai, Shu; Schaeffer, David G.

    2010-01-01

    Instabilities in cardiac dynamics have been widely investigated in recent years. One facet of this work has studied chaotic behavior, especially possible correlations with fatal arrhythmias. Previously chaotic behavior was observed in various models, specifically in the breakup of spiral and scroll waves. In this paper we study cardiac dynamics and find spatiotemporal chaotic behavior through the Echebarria–Karma modulation equation for alternans in one dimension. Although extreme parameter values are required to produce chaos in this model, it seems significant mathematically that chaos may occur by a different mechanism from previous observations. PMID:20590327

  7. The role of conductivity discontinuities in design of cardiac defibrillation

    NASA Astrophysics Data System (ADS)

    Lim, Hyunkyung; Cun, Wenjing; Wang, Yue; Gray, Richard A.; Glimm, James

    2018-01-01

    Fibrillation is an erratic electrical state of the heart, of rapid twitching rather than organized contractions. Ventricular fibrillation is fatal if not treated promptly. The standard treatment, defibrillation, is a strong electrical shock to reinitialize the electrical dynamics and allow a normal heart beat. Both the normal and the fibrillatory electrical dynamics of the heart are organized into moving wave fronts of changing electrical signals, especially in the transmembrane voltage, which is the potential difference between the cardiac cellular interior and the intracellular region of the heart. In a normal heart beat, the wave front motion is from bottom to top and is accompanied by the release of Ca ions to induce contractions and pump the blood. In a fibrillatory state, these wave fronts are organized into rotating scroll waves, with a centerline known as a filament. Treatment requires altering the electrical state of the heart through an externally applied electrical shock, in a manner that precludes the existence of the filaments and scroll waves. Detailed mechanisms for the success of this treatment are partially understood, and involve local shock-induced changes in the transmembrane potential, known as virtual electrode alterations. These transmembrane alterations are located at boundaries of the cardiac tissue, including blood vessels and the heart chamber wall, where discontinuities in electrical conductivity occur. The primary focus of this paper is the defibrillation shock and the subsequent electrical phenomena it induces. Six partially overlapping causal factors for defibrillation success are identified from the literature. We present evidence in favor of five of these and against one of them. A major conclusion is that a dynamically growing wave front starting at the heart surface appears to play a primary role during defibrillation by critically reducing the volume available to sustain the dynamic motion of scroll waves; in contrast, virtual electrodes occurring at the boundaries of small, isolated blood vessels only cause minor effects. As a consequence, we suggest that the size of the heart (specifically, the surface to volume ratio) is an important defibrillation variable.

  8. Resting spontaneous baroreflex sensitivity and cardiac autonomic control in anabolic androgenic steroid users

    PubMed Central

    dos Santos, Marcelo R.; Sayegh, Ana L.C.; Armani, Rafael; Costa-Hong, Valéria; de Souza, Francis R.; Toschi-Dias, Edgar; Bortolotto, Luiz A.; Yonamine, Mauricio; Negrão, Carlos E.; Alves, Maria-Janieire N.N.

    2018-01-01

    OBJECTIVES: Misuse of anabolic androgenic steroids in athletes is a strategy used to enhance strength and skeletal muscle hypertrophy. However, its abuse leads to an imbalance in muscle sympathetic nerve activity, increased vascular resistance, and increased blood pressure. However, the mechanisms underlying these alterations are still unknown. Therefore, we tested whether anabolic androgenic steroids could impair resting baroreflex sensitivity and cardiac sympathovagal control. In addition, we evaluate pulse wave velocity to ascertain the arterial stiffness of large vessels. METHODS: Fourteen male anabolic androgenic steroid users and 12 nonusers were studied. Heart rate, blood pressure, and respiratory rate were recorded. Baroreflex sensitivity was estimated by the sequence method, and cardiac autonomic control by analysis of the R-R interval. Pulse wave velocity was measured using a noninvasive automatic device. RESULTS: Mean spontaneous baroreflex sensitivity, baroreflex sensitivity to activation of the baroreceptors, and baroreflex sensitivity to deactivation of the baroreceptors were significantly lower in users than in nonusers. In the spectral analysis of heart rate variability, high frequency activity was lower, while low frequency activity was higher in users than in nonusers. Moreover, the sympathovagal balance was higher in users. Users showed higher pulse wave velocity than nonusers showing arterial stiffness of large vessels. Single linear regression analysis showed significant correlations between mean blood pressure and baroreflex sensitivity and pulse wave velocity. CONCLUSIONS: Our results provide evidence for lower baroreflex sensitivity and sympathovagal imbalance in anabolic androgenic steroid users. Moreover, anabolic androgenic steroid users showed arterial stiffness. Together, these alterations might be the mechanisms triggering the increased blood pressure in this population. PMID:29791601

  9. Resting spontaneous baroreflex sensitivity and cardiac autonomic control in anabolic androgenic steroid users.

    PubMed

    Santos, Marcelo R Dos; Sayegh, Ana L C; Armani, Rafael; Costa-Hong, Valéria; Souza, Francis R de; Toschi-Dias, Edgar; Bortolotto, Luiz A; Yonamine, Mauricio; Negrão, Carlos E; Alves, Maria-Janieire N N

    2018-05-21

    Misuse of anabolic androgenic steroids in athletes is a strategy used to enhance strength and skeletal muscle hypertrophy. However, its abuse leads to an imbalance in muscle sympathetic nerve activity, increased vascular resistance, and increased blood pressure. However, the mechanisms underlying these alterations are still unknown. Therefore, we tested whether anabolic androgenic steroids could impair resting baroreflex sensitivity and cardiac sympathovagal control. In addition, we evaluate pulse wave velocity to ascertain the arterial stiffness of large vessels. Fourteen male anabolic androgenic steroid users and 12 nonusers were studied. Heart rate, blood pressure, and respiratory rate were recorded. Baroreflex sensitivity was estimated by the sequence method, and cardiac autonomic control by analysis of the R-R interval. Pulse wave velocity was measured using a noninvasive automatic device. Mean spontaneous baroreflex sensitivity, baroreflex sensitivity to activation of the baroreceptors, and baroreflex sensitivity to deactivation of the baroreceptors were significantly lower in users than in nonusers. In the spectral analysis of heart rate variability, high frequency activity was lower, while low frequency activity was higher in users than in nonusers. Moreover, the sympathovagal balance was higher in users. Users showed higher pulse wave velocity than nonusers showing arterial stiffness of large vessels. Single linear regression analysis showed significant correlations between mean blood pressure and baroreflex sensitivity and pulse wave velocity. Our results provide evidence for lower baroreflex sensitivity and sympathovagal imbalance in anabolic androgenic steroid users. Moreover, anabolic androgenic steroid users showed arterial stiffness. Together, these alterations might be the mechanisms triggering the increased blood pressure in this population.

  10. Validation of the inverse pulse wave transit time series as surrogate of systolic blood pressure in MVAR modeling.

    PubMed

    Giassi, Pedro; Okida, Sergio; Oliveira, Maurício G; Moraes, Raimes

    2013-11-01

    Short-term cardiovascular regulation mediated by the sympathetic and parasympathetic branches of the autonomic nervous system has been investigated by multivariate autoregressive (MVAR) modeling, providing insightful analysis. MVAR models employ, as inputs, heart rate (HR), systolic blood pressure (SBP) and respiratory waveforms. ECG (from which HR series is obtained) and respiratory flow waveform (RFW) can be easily sampled from the patients. Nevertheless, the available methods for acquisition of beat-to-beat SBP measurements during exams hamper the wider use of MVAR models in clinical research. Recent studies show an inverse correlation between pulse wave transit time (PWTT) series and SBP fluctuations. PWTT is the time interval between the ECG R-wave peak and photoplethysmography waveform (PPG) base point within the same cardiac cycle. This study investigates the feasibility of using inverse PWTT (IPWTT) series as an alternative input to SBP for MVAR modeling of the cardiovascular regulation. For that, HR, RFW, and IPWTT series acquired from volunteers during postural changes and autonomic blockade were used as input of MVAR models. Obtained results show that IPWTT series can be used as input of MVAR models, replacing SBP measurements in order to overcome practical difficulties related to the continuous sampling of the SBP during clinical exams.

  11. STRUCTURAL AND FUNCTIONAL BASES OF CARDIAC FIBRILLATION. DIFFERENCES AND SIMILARITIES BETWEEN ATRIA AND VENTRICLES

    PubMed Central

    Filgueiras-Rama, David; Jalife, José

    2016-01-01

    Evidence accumulated over the last 25 years suggests that, whether in the atria or ventricles, fibrillation may be explained by the self-organization of the cardiac electrical activity into rapidly spinning rotors giving way to spiral waves that break intermittently and result in fibrillatory conduction. The dynamics and frequency of such rotors depend on the ion channel composition, excitability and refractory properties of the tissues involved, as well as on the thickness and respective three-dimensional fiber structure of the atrial and ventricular chambers. Therefore, improving the understanding of fibrillation has required the use of multidisciplinary research approaches, including optical mapping, patch clamping and molecular biology, and the application of concepts derived from the theory of wave propagation in excitable media. Moreover, translation of such concepts to the clinic has recently opened new opportunities to apply novel mechanistic approaches to therapy, particularly during atrial fibrillation ablation. Here we review the current understanding of the manner in which the underlying myocardial structure and function influence rotor initiation and maintenance during cardiac fibrillation. We also examine relevant underlying differences and similarities between atrial fibrillation and ventricular fibrillation and evaluate the latest clinical mapping technologies used to identify rotors in either arrhythmia. Altogether, the data being discussed have significantly improved our understanding of the cellular and structural bases of cardiac fibrillation and pointed toward potentially exciting new avenues for more efficient and effective identification and therapy of the most complex cardiac arrhythmias. PMID:27042693

  12. Magnetic resonance imaging reveals elevated aortic pulse wave velocity in obese and overweight adolescents.

    PubMed

    Caterini, J E; Banks, L; Wells, G D; Cifra, B; Slorach, C; McCrindle, B W; Seed, M

    2017-12-01

    The aortic pulse wave velocity (PWV) measured via cardiac magnetic resonance (CMR) can be used to non-invasively assess changes in arterial stiffness and potential underlying vascular dysfunction. This technique could unmask early arterial dysfunction in overweight and obese youth at risk for cardiovascular disease. We sought to determine the association between vascular stiffness, percentage body fat, body mass index (BMI), and cardiac function in adolescents across the weight spectrum through both CMR and standard applanation tonometry (AT)-based PWV measurements. PWV and left-ventricular cardiac function were assessed using 3.0 T CMR in obese and overweight (OB/OW) participants (n = 12) and controls (n = 7). PWV was also estimated via carotid-femoral AT. OB/OW participants did not differ from healthy-weight controls regarding cardiometabolic risk factors or physical activity levels, but there was a trend towards higher levels of triglycerides in obese/overweight participants (P = 0.07). Mean PWV was higher in obese participants when corrected for age and sex (P = 0.01), and was positively associated with BMI (β = 0.51, P = 0.02). PWV estimated through AT was not significantly different between groups. Cardiac function measured by left-ventricular ejection fraction z-score was inversely associated with mean PWV (β = -0.57, P = 0.026). Increasing arterial stiffness and decreasing cardiac function were evident among our overweight and obese cohort. PWV estimated by CMR could detect early increases in arterial stiffness vs. traditional AT measurements of PWV. © 2017 World Obesity Federation.

  13. Utility of heart rate turbulence and T-Wave alternans to assess risk for Re-admission and cardiac death in hospitalized heart failure patients.

    PubMed

    Yamada, Shinya; Yoshihisa, Akiomi; Sato, Yu; Sato, Takamasa; Kamioka, Masashi; Kaneshiro, Takashi; Oikawa, Masayoshi; Kobayashi, Atsushi; Suzuki, Hitoshi; Ishida, Takafumi; Takeishi, Yasuchika

    2018-05-18

    Heart failure (HF) patients have a higher risk of recurrent HF and cardiac death, and electrical remodeling is considered to be an important factor for HF progression. The present study aimed to validate the utility of electrocardiogram and Holter monitoring for the risk stratification of HF patients. Our study comprised 215 patients (144 males, mean age 62 years) who had been hospitalized due to acute decompensated HF. Electrocardiogram (QRS duration and QTc interval) and 24-hour Holter monitoring (heart rate variability, heart rate turbulence and T-wave alternans [TWA]) were performed in stable condition before discharge. The clinical characteristics and outcomes were then investigated. During a median follow-up period of 2.7 years, there were 83 (38.6%) cardiac events (re-hospitalization due to worsening HF [n = 51] or cardiac death [n = 32]). The patients with cardiac events had a lower turbulence slope (TS) and higher TWA compared to those without cardiac events (TS, 3.0±5.5 ms/RR vs. 5.3±5.6 ms/RR, P = 0.001; TWA, 66.1±19.6 μV vs. 54.7±15.1 μV, P < 0.001). Univariable analysis showed that TS, TWA, QRS duration, and QTc interval were associated with cardiac events (P = 0.004, P < 0.001, P = 0.037 and P = 0.024, respectively), while the multivariable analysis after the adjustment of multiple confounders showed that TS and TWA were independent predictive factors of cardiac events with a hazard ratio of 0.936 and 1.015 (95% confidence interval [CI]: 0.860-0.974, P = 0.006; and 95% CI: 1.003-1.027, p = 0.016), respectively. The measurement of TS and TWA is useful for assessing risk for re-hospitalization and cardiac death in HF patients. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  14. Imaging the propagation of the electromechanical wave in heart failure patients with cardiac resynchronization therapy

    PubMed Central

    Bunting, Ethan; Lambrakos, Litsa; Kemper, Paul; Whang, William; Garan, Hasan; Konofagou, Elisa

    2016-01-01

    Background Current electrocardiographic and echocardiographic measurements in heart failure (HF) do not take into account the complex interplay between electrical activation and local wall motion. The utilization of novel technologies to better characterize cardiac electromechanical behavior may lead to improved response rates with cardiac resynchronization therapy (CRT). Electromechanical Wave Imaging (EWI) is a non-invasive ultrasound-based technique that uses the transient deformations of the myocardium to track the intrinsic electromechanical wave that precedes myocardial contraction. In this paper, we investigate the performance and reproducibility of EWI in the assessment of HF patients and CRT. Methods EWI acquisitions were obtained in 5 healthy controls and 16 HF patients with and without CRT pacing. Responders (n=8) and non-responders (n=8) to CRT were identified retrospectively on the basis of left ventricular (LV) reverse remodeling. Electromechanical activation maps were obtained in all patients and used to compute a quantitative parameter describing the mean activation time of the LV lateral wall (LWAT). Results Mean LWAT was increased by 52.1 ms in HF patients in native rhythm compared to controls (p<0.01). For all HF patients, CRT pacing initiated a different electromechanical activation sequence. Responders exhibited a 56.4±28.9 ms reduction in LWAT with CRT pacing (p<0.01), while non-responders showed no significant change. Conclusion In this initial feasibility study, EWI was capable of characterizing local cardiac electromechanical behavior as it pertains to HF and CRT response. Activation sequences obtained with EWI allow for quantification of LV lateral wall electromechanical activation, thus providing a novel method for CRT assessment. PMID:27790723

  15. Does ketogenic diet have any negative effect on cardiac systolic and diastolic functions in children with intractable epilepsy?: One-year follow-up results.

    PubMed

    Ozdemir, Rahmi; Kucuk, Mehmet; Guzel, Orkide; Karadeniz, Cem; Yilmaz, Unsal; Mese, Timur

    2016-10-01

    The ketogenic diet (KD) has been referred to as an "effective therapy with side effects" for children with intractable epilepsy. Among the most recognized adverse effects, there are cardiac conduction abnormalities, vascular and myocardial dysfunction. However, very limited and controversial data are available regarding the effects of the KD on cardiac functions. We sought to analyze the mid-term effect of ketogenic diet on cardiac functions in patients with intractable epilepsy who received a ketogenic diet for at least 12months using conventional and relatively new imaging techniques. This prospective study included 61 patients with intractable epilepsy who received ketogenic diet for at least 12months. Clinical examinations, serum carnitine and selenium levels as well as electrocardiographic and echocardiographic examinations were scheduled prior to the procedure and at 1, 3, 6 and 12months. We utilized two-dimensional, M-mode, colored Doppler, spectral Doppler and pulsed wave tissue Doppler imaging techniques to investigate ventricular systolic and diastolic functions of this subgroup of patients. In our study, there was no significant difference after 1year of KD therapy compared to baseline values-except a significantly decreased A wave velocity-in terms of pulse wave Doppler echocardiographic measurements of the diastolic function. The tissue Doppler measurements obtained from the lateral wall of tricuspide and mitral annuli were not different at baseline and at month 12 of the treatment, as well. The ketogenic diet appears to have no disturbing effect on ventricular functions in epileptic children in the midterm. Copyright © 2016 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  16. T-wave alternans, air pollution and traffic in high-risk subjects.

    PubMed

    Zanobetti, Antonella; Stone, Peter H; Speizer, Frank E; Schwartz, Joel D; Coull, Brent A; Suh, Helen H; Nearing, Bruce D; Mittleman, Murray A; Verrier, Richard L; Gold, Diane R

    2009-09-01

    Particulate pollution has been linked to risk for cardiac death; possible mechanisms include pollution-related increases in cardiac electrical instability. T-wave alternans (TWA) is a marker of cardiac electrical instability measured as differences in the magnitude between adjacent T waves. In a repeated-measures study of 48 patients aged 43 to 75 years, associations of ambient and home indoor particulate pollution, including black carbon (BC) and reports of traffic exposure, with changes in 0.5-hourly maximum TWA (TWA-MAX), measured by 24-hour Holter electrocardiographic monitoring, were investigated. Each patient was observed up to 4 times within 1 year after percutaneous intervention for myocardial infarction, acute coronary syndromes without infarction, or stable coronary artery disease, for a total of 5,830 0.5-hour observations. Diary data for each 0.5-hour period defined whether a patient was home or not home, or in traffic. Increases in TWA-MAX were independently associated with the previous 2-hour mean ambient BC (2.1%, 95% confidence interval 0.9% to 3.3%) and with being in traffic in the previous 2 hours (6.1%, 95% confidence interval 3.4% to 8.8%). When subjects were home, indoor home BC effects were largest and most precise; when subjects were away from home, ambient central site BC effects were strongest. Increases in pollution increased the odds of TWA-MAX > or =75th percentile (odds ratio 1.4, 95% confidence interval 1.2 to 1.6 for a 1 microg/m(3) increase in 6-hour mean BC). In conclusion, after hospitalization for coronary artery disease, being in traffic and short-term ambient or indoor BC exposure increased TWA, a marker of cardiac electrical instability.

  17. In vitro electrocardiographic and cardiac ion channel effects of (-)-epigallocatechin-3-gallate, the main catechin of green tea.

    PubMed

    Kang, Jiesheng; Cheng, Hsien; Ji, Junzhi; Incardona, Josephine; Rampe, David

    2010-08-01

    Epigallocatechin-3-gallate (EGCG) is the major catechin found in green tea. EGCG is also available for consumption in the form of concentrated over-the-counter nutritional supplements. This compound is currently undergoing clinical trials for the treatment of a number of diseases including multiple sclerosis, and a variety of cancers. To date, few data exist regarding the effects of EGCG on the electrophysiology of the heart. Therefore, we examined the effects of EGCG on the electrocardiogram recorded from Langendorff-perfused guinea pig hearts and on cardiac ion channels using patch-clamp electrophysiology. EGCG had no significant effects on the electrocardiogram at concentrations of 3 and 10 microM. At 30 microM, EGCG prolonged PR and QRS intervals, slightly shortened the QT interval, and altered the shape of the ST-T-wave segment. The ST segment merged with the upstroke of the T wave, and we noted a prolongation in the time from the peak of the T wave until the end. Patch-clamp studies identified the KvLQT1/minK K(+) channel as a target for EGCG (IC(50) = 30.1 microM). In addition, EGCG inhibited the cloned human cardiac Na(+) channel Na(v)1.5 in a voltage-dependent fashion. The L-type Ca(2+) channel was inhibited by 20.8% at 30 microM, whereas the human ether-a-go-go-related gene and Kv4.3 cardiac K(+) channels were less sensitive to inhibition by EGCG. ECGC has a number of electrophysiological effects in the heart, and these effects may have clinical significance when multigram doses of this compound are used in human clinical trials or through self-ingestion of large amounts of over-the-counter products enriched in EGCG.

  18. Identification of capillary rarefaction using intracoronary wave intensity analysis with resultant prognostic implications for cardiac allograft patients.

    PubMed

    Broyd, Christopher J; Hernández-Pérez, Francisco; Segovia, Javier; Echavarría-Pinto, Mauro; Quirós-Carretero, Alicia; Salas, Clara; Gonzalo, Nieves; Jiménez-Quevedo, Pilar; Nombela-Franco, Luis; Salinas, Pablo; Núñez-Gil, Ivan; Del Trigo, Maria; Goicolea, Javier; Alonso-Pulpón, Luis; Fernández-Ortiz, Antonio; Parker, Kim; Hughes, Alun; Mayet, Jamil; Davies, Justin; Escaned, Javier

    2018-05-21

    Techniques for identifying specific microcirculatory structural changes are desirable. As such, capillary rarefaction constitutes one of the earliest changes of cardiac allograft vasculopathy (CAV) in cardiac allograft recipients, but its identification with coronary flow reserve (CFR) or intracoronary resistance measurements is hampered because of non-selective interrogation of the capillary bed. We therefore investigated the potential of wave intensity analysis (WIA) to assess capillary rarefaction and thereby predict CAV. Fifty-two allograft patients with unobstructed coronary arteries and normal left ventricular (LV) function were assessed. Adequate aortic pressure and left anterior descending artery flow measurements at rest and with intracoronary adenosine were obtained in 46 of which 2 were lost to follow-up. In a subgroup of 15 patients, simultaneous RV biopsies were obtained and analysed for capillary density. Patients were followed up with 1-3 yearly screening angiography. A significant relationship with capillary density was noted with CFR (r = 0.52, P = 0.048) and the backward decompression wave (BDW) (r = -0.65, P < 0.01). Over a mean follow-up of 9.3 ± 5.2 years patients with a smaller BDW had an increased risk of developing angiographic CAV (hazard ratio 2.89, 95% CI 1.12-7.39; P = 0.03). Additionally, the index BDW was lower in those who went on to have a clinical CAV-events (P = 0.04) as well as more severe disease (P = 0.01). Within cardiac transplant patients, WIA is able to quantify the earliest histological changes of CAV and can predict clinical and angiographic outcomes. This proof-of-concept for WIA also lends weight to its use in the assessment of other disease processes in which capillary rarefaction is involved.

  19. Spiral wave classification using normalized compression distance: Towards atrial tissue spatiotemporal electrophysiological behavior characterization.

    PubMed

    Alagoz, Celal; Guez, Allon; Cohen, Andrew; Bullinga, John R

    2015-08-01

    Analysis of electrical activation patterns such as re-entries during atrial fibrillation (Afib) is crucial in understanding arrhythmic mechanisms and assessment of diagnostic measures. Spiral waves are a phenomena that provide intuitive basis for re-entries occurring in cardiac tissue. Distinct spiral wave behaviors such as stable spiral waves, meandering spiral waves, and spiral wave break-up may have distinct electrogram manifestations on a mapping catheter. Hence, it is desirable to have an automated classification of spiral wave behavior based on catheter recordings for a qualitative characterization of spatiotemporal electrophysiological activity on atrial tissue. In this study, we propose a method for classification of spatiotemporal characteristics of simulated atrial activation patterns in terms of distinct spiral wave behaviors during Afib using two different techniques: normalized compressed distance (NCD) and normalized FFT (NFFTD). We use a phenomenological model for cardiac electrical propagation to produce various simulated spiral wave behaviors on a 2D grid and labeled them as stable, meandering, or breakup. By mimicking commonly used catheter types, a star shaped and a circular shaped both of which do the local readings from atrial wall, monopolar and bipolar intracardiac electrograms are simulated. Virtual catheters are positioned at different locations on the grid. The classification performance for different catheter locations, types and for monopolar or bipolar readings were also compared. We observed that the performance for each case differed slightly. However, we found that NCD performance is superior to NFFTD. Through the simulation study, we showed the theoretical validation of the proposed method. Our findings suggest that a qualitative wavefront activation pattern can be assessed during Afib without the need for highly invasive mapping techniques such as multisite simultaneous electrogram recordings.

  20. T-wave area as biomarker of clinical response to cardiac resynchronization therapy.

    PubMed

    Végh, Eszter M; Engels, Elien B; van Deursen, Caroline J M; Merkely, Béla; Vernooy, Kevin; Singh, Jagmeet P; Prinzen, Frits W

    2016-07-01

    There is increasing evidence that left bundle branch block (LBBB) morphology on the electrocardiogram is a positive predictor for response to cardiac resynchronization therapy (CRT). We previously demonstrated that the vectorcardiography (VCG)-derived T-wave area predicts echocardiographic CRT response in LBBB patients. In the present study, we investigate whether the T-wave area also predicts long-term clinical outcome to CRT. This is a retrospective study consisting of 335 CRT recipients. Primary endpoint were the composite of heart failure (HF) hospitalization, heart transplantation, left ventricular assist device implantation or death during a 3-year follow-up period. HF hospitalization and death alone were secondary endpoints. The patient subgroup with a large T-wave area and LBBB 36% reached the primary endpoint, which was considerably less (P < 0.01) than for patients with LBBB and a small T-wave area or non-LBBB patients with a small or large T-wave area (48, 57, and 51%, respectively). Similar differences were observed for the secondary endpoints, HF hospitalization (31 vs. 51, 51, and 38%, respectively, P < 0.01) and death (19 vs. 42, 34, and 42%, respectively, P < 0.01). In multivariate analysis, a large T-wave area and LBBB were the only independent predictors of the combined endpoint besides high creatinine levels and use of diuretics. T-wave area may be useful as an additional biomarker to stratify CRT candidates and improve selection of those most likely to benefit from CRT. A large T-wave area may derive its predictive value from reflecting good intrinsic myocardial properties and a substrate for CRT. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  1. Prevalence of E/A wave fusion and A wave truncation in DDD pacemaker patients with complete AV block under nominal AV intervals.

    PubMed

    Poller, Wolfram C; Dreger, Henryk; Schwerg, Marius; Melzer, Christoph

    2015-01-01

    Optimization of the AV-interval (AVI) in DDD pacemakers improves cardiac hemodynamics and reduces pacemaker syndromes. Manual optimization is typically not performed in clinical routine. In the present study we analyze the prevalence of E/A wave fusion and A wave truncation under resting conditions in 160 patients with complete AV block (AVB) under the pre-programmed AVI. We manually optimized sub-optimal AVI. We analyzed 160 pacemaker patients with complete AVB, both in sinus rhythm (AV-sense; n = 129) and under atrial pacing (AV-pace; n = 31). Using Doppler analyses of the transmitral inflow we classified the nominal AVI as: a) normal, b) too long (E/A wave fusion) or c) too short (A wave truncation). In patients with a sub-optimal AVI, we performed manual optimization according to the recommendations of the American Society of Echocardiography. All AVB patients with atrial pacing exhibited a normal transmitral inflow under the nominal AV-pace intervals (100%). In contrast, 25 AVB patients in sinus rhythm showed E/A wave fusion under the pre-programmed AV-sense intervals (19.4%; 95% confidence interval (CI): 12.6-26.2%). A wave truncations were not observed in any patient. All patients with a complete E/A wave fusion achieved a normal transmitral inflow after AV-sense interval reduction (mean optimized AVI: 79.4 ± 13.6 ms). Given the rate of 19.4% (CI 12.6-26.2%) of patients with a too long nominal AV-sense interval, automatic algorithms may prove useful in improving cardiac hemodynamics, especially in the subgroup of atrially triggered pacemaker patients with AV node diseases.

  2. The Normal Electrocardiogram: Resting 12-Lead and Electrocardiogram Monitoring in the Hospital.

    PubMed

    Harris, Patricia R E

    2016-09-01

    The electrocardiogram (ECG) is a well-established diagnostic tool extensively used in clinical settings. Knowledge of cardiac rhythm and mastery of cardiac waveform interpretation are fundamental for intensive care nurses. Recognition of the normal findings for the 12-lead ECG and understanding the significance of changes from baseline in continuous cardiac monitoring are essential steps toward ensuring safe patient care. This article highlights historical developments in electrocardiography, describes the normal resting 12-lead ECG, and discusses the need for continuous cardiac monitoring. In addition, future directions for the ECG are explored briefly. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Magnetic plethysmograph transducers for local blood pulse wave velocity measurement.

    PubMed

    Nabeel, P M; Joseph, Jayaraj; Sivaprakasam, Mohanasankar

    2014-01-01

    We present the design of magnetic plethysmograph (MPG) transducers for detection of blood pulse waveform and evaluation of local pulse wave velocity (PWV), for potential use in cuffless blood pressure (BP) monitoring. The sensors utilize a Hall effect magnetic field sensor to capture the blood pulse waveform. A strap based design is performed to enable reliable capture of large number of cardiac cycles with relative ease. The ability of the transducer to consistently detect the blood pulse is verified by in-vivo trials on few volunteers. A duality of such transducers is utilized to capture the local PWV at the carotid artery. The pulse transit time (PTT) between the two detected pulse waveforms, measured along a small section of the carotid artery, was evaluated using automated algorithms to ensure consistency of measurements. The correlation between the measured values of local PWV and BP was also investigated. The developed transducers provide a reliable, easy modality for detecting pulse waveform on superficial arteries. Such transducers, used for measurement of local PWV, could potentially be utilized for cuffless, continuous evaluation of BP at various superficial arterial sites.

  4. Heart Fibrillation and Parallel Supercomputers

    NASA Technical Reports Server (NTRS)

    Kogan, B. Y.; Karplus, W. J.; Chudin, E. E.

    1997-01-01

    The Luo and Rudy 3 cardiac cell mathematical model is implemented on the parallel supercomputer CRAY - T3D. The splitting algorithm combined with variable time step and an explicit method of integration provide reasonable solution times and almost perfect scaling for rectilinear wave propagation. The computer simulation makes it possible to observe new phenomena: the break-up of spiral waves caused by intracellular calcium and dynamics and the non-uniformity of the calcium distribution in space during the onset of the spiral wave.

  5. Pulse wave velocity and cardiac autonomic function in type 2 diabetes mellitus.

    PubMed

    Chorepsima, Stamatina; Eleftheriadou, Ioanna; Tentolouris, Anastasios; Moyssakis, Ioannis; Protogerou, Athanasios; Kokkinos, Alexandros; Sfikakis, Petros P; Tentolouris, Nikolaos

    2017-05-19

    Increased carotid-femoral pulse wave velocity (PWV) has been associated with incident cardiovascular disease, independently of traditional risk factors. Cardiac autonomic dysfunction is a common complication of diabetes and has been associated with reduced aortic distensibility. However, the association of cardiac autonomic dysfunction with PWV is not known. In this study we examined the association between cardiac autonomic function and PWV in subjects with type 2 diabetes mellitus. A total of 290 patients with type 2 diabetes were examined. PWV was measured at the carotid-femoral segment with applanation tonometry. Central mean arterial blood pressure (MBP) was determined by the same apparatus. Participants were classified as having normal (n = 193) or abnormal (n = 97) PWV values using age-corrected values. Cardiac autonomic nervous system activity was determined by measurement of parameters of heart rate variability (HRV). Subjects with abnormal PWV were older, had higher arterial blood pressure and higher heart rate than those with normal PWV. Most of the values of HRV were significantly lower in subjects with abnormal than in those with normal PWV. Multivariate analysis, after controlling for various confounding factors, demonstrated that abnormal PWV was associated independently only with peripheral MBP [odds ratio (OR) 1.049, 95% confidence intervals (CI) 1.015-1.085, P = 0.005], central MBP (OR 1.052, 95% CI 1.016-1.088, P = 0.004), log total power (OR 0.490, 95% CI 0.258-0.932, P = 0.030) and log high frequency power (OR 0.546, 95% CI 0.301-0.991, P = 0.047). In subjects with type 2 diabetes, arterial blood pressure and impaired cardiac autonomic function is associated independently with abnormal PWV.

  6. Advanced ECG in 2016: is there more than just a tracing?

    PubMed

    Reichlin, Tobias; Abächerli, Roger; Twerenbold, Raphael; Kühne, Michael; Schaer, Beat; Müller, Christian; Sticherling, Christian; Osswald, Stefan

    2016-01-01

    The 12-lead electrocardiogram (ECG) is the most frequently used technology in clinical cardiology. It is critical for evidence-based management of patients with most cardiovascular conditions, including patients with acute myocardial infarction, suspected chronic cardiac ischaemia, cardiac arrhythmias, heart failure and implantable cardiac devices. In contrast to many other techniques in cardiology, the ECG is simple, small, mobile, universally available and cheap, and therefore particularly attractive. Standard ECG interpretation mainly relies on direct visual assessment. The progress in biomedical computing and signal processing, and the available computational power offer fascinating new options for ECG analysis relevant to all fields of cardiology. Several digital ECG markers and advanced ECG technologies have shown promise in preliminary studies. This article reviews promising novel surface ECG technologies in three different fields. (1) For the detection of myocardial ischaemia and infarction, QRS morphology feature analysis, the analysis of high frequency QRS components (HF-QRS) and methods using vectorcardiography as well as ECG imaging are discussed. (2) For the identification and management of patients with cardiac arrhythmias, methods of advanced P-wave analysis are discussed and the concept of ECG imaging for noninvasive localisation of cardiac arrhythmias is presented. (3) For risk stratification of sudden cardiac death and the selection of patients for medical device therapy, several novel markers including an automated QRS-score for scar quantification, the QRS-T angle or the T-wave peak-to-end-interval are discussed. Despite the existing preliminary data, none of the advanced ECG markers and technologies has yet accomplished the transition into clinical practice. Further refinement of these technologies and broader validation in large unselected patient cohorts are the critical next step needed to facilitate translation of advanced ECG technologies into clinical cardiology.

  7. Low-energy Control of Electrical Turbulence in the Heart

    PubMed Central

    Luther, Stefan; Fenton, Flavio H.; Kornreich, Bruce G.; Squires, Amgad; Bittihn, Philip; Hornung, Daniel; Zabel, Markus; Flanders, James; Gladuli, Andrea; Campoy, Luis; Cherry, Elizabeth M.; Luther, Gisa; Hasenfuss, Gerd; Krinsky, Valentin I.; Pumir, Alain; Gilmour, Robert F.; Bodenschatz, Eberhard

    2011-01-01

    Controlling the complex spatio-temporal dynamics underlying life-threatening cardiac arrhythmias such as fibrillation is extremely difficult due to the nonlinear interaction of excitation waves within a heterogeneous anatomical substrate1–4. Lacking a better strategy, strong, globally resetting electrical shocks remain the only reliable treatment for cardiac fibrillation5–7. Here, we establish the relation between the response of the tissue to an electric field and the spatial distribution of heterogeneities of the scale-free coronary vascular structure. We show that in response to a pulsed electric field E, these heterogeneities serve as nucleation sites for the generation of intramural electrical waves with a source density ρ(E), and a characteristic time τ for tissue depolarization that obeys a power law τ∝Eα. These intramural wave sources permit targeting of electrical turbulence near the cores of the vortices of electrical activity that drive complex fibrillatory dynamics. We show in vitro that simultaneous and direct access to multiple vortex cores results in rapid synchronization of cardiac tissue and therefore efficient termination of fibrillation. Using this novel control strategy, we demonstrate, for the first time, low-energy termination of fibrillation in vivo. Our results give new insights into the mechanisms and dynamics underlying the control of spatio-temporal chaos in heterogeneous excitable media and at the same time provide new research perspectives towards alternative, life-saving low-energy defibrillation techniques. PMID:21753855

  8. Design and testing of an MRI-compatible cycle ergometer for non-invasive cardiac assessments during exercise

    PubMed Central

    2012-01-01

    Background Magnetic resonance imaging (MRI) is an important tool for cardiac research, and it is frequently used for resting cardiac assessments. However, research into non-pharmacological stress cardiac evaluation is limited. Methods We aimed to design a portable and relatively inexpensive MRI cycle ergometer capable of continuously measuring pedalling workload while patients exercise to maintain target heart rates. Results We constructed and tested an MRI-compatible cycle ergometer for a 1.5 T MRI scanner. Resting and sub-maximal exercise images (at 110 beats per minute) were successfully obtained in 8 healthy adults. Conclusions The MRI-compatible cycle ergometer constructed by our research group enabled cardiac assessments at fixed heart rates, while continuously recording power output by directly measuring pedal force and crank rotation. PMID:22423637

  9. Dynamic characteristic mechanism of atrial septal defect using real-time three-dimensional echocardiography and evaluation of right ventricular functions.

    PubMed

    Sharen, Gao-Wa; Zhang, Jun; Qin, Chuan; Lv, Qing

    2017-02-01

    The dynamic characteristics of the area of the atrial septal defect (ASD) were evaluated using the technique of real-time three-dimensional echocardiography (RT 3DE), the potential factors responsible for the dynamic characteristics of the area of ASD were observed, and the overall and local volume and functions of the patients with ASD were measured. RT 3DE was performed on the 27 normal controls and 28 patients with ASD. Based on the three-dimensional data workstations, the area of ASD was measured at P wave vertex, R wave vertex, T wave starting point, and T wave terminal point and in the T-P section. The right atrial volume in the same time phase of the cardiac cycle and the motion displacement distance of the tricuspid annulus in the corresponding period were measured. The measured value of the area of ASD was analyzed. The changes in the right atrial volume and the motion displacement distance of the tricuspid annulus in the normal control group and the ASD group were compared. The right ventricular ejection fractions in the normal control group and the ASD group were compared using the RT 3DE long-axis eight-plane (LA 8-plane) method. Real-time three-dimensional volume imaging was performed in the normal control group and ASD group (n=30). The right ventricular inflow tract, outflow tract, cardiac apex muscular trabecula dilatation, end-systolic volume, overall dilatation, end-systolic volume, and appropriate local and overall ejection fractions in both two groups were measured with the four-dimensional right ventricular quantitative analysis method (4D RVQ) and compared. The overall right ventricular volume and the ejection fraction measured by the LA 8-plane method and 4D RVQ were subjected to a related analysis. Dynamic changes occurred to the area of ASD in the cardiac cycle. The rules for dynamic changes in the area of ASD and the rules for changes in the right atrial volume in the cardiac cycle were consistent. The maximum value of the changes in the right atrial volume occurred in the end-systolic period when the peak of the curve appeared. The minimum value of the changes occurred in the end-systolic period and was located at the lowest point of the volume variation curve. The area variation curve for ASD and the motion variation curve for the tricuspid annulus in the cardiac cycle were the same. The displacement of the tricuspid annulus exhibited directionality. The measured values of the area of ASD at P wave vertex, R wave vertex, T wave starting point, T wave terminal point and in the T-P section were properly correlated with the right atrial volume (P<0.001). The area of ASD and the motion displacement distance of the tricuspid annulus were negatively correlated (P<0.05). The right atrial volumes in the ASD group in the cardiac cycle in various time phases increased significantly as compared with those in the normal control group (P=0.0001). The motion displacement distance of the tricuspid annulus decreased significantly in the ASD group as compared with that in the normal control group (P=0.043). The right ventricular ejection fraction in the ASD group was lower than that in the normal control group (P=0.032). The ejection fraction of the cardiac apex trabecula of the ASD patients was significantly lower than the ejection fractions of the right ventricular outflow tract and inflow tract and overall ejection fraction. The difference was statistically significant (P=0.005). The right ventricular local and overall dilatation and end-systolic volumes in the ASD group increased significantly as compared with those in the normal control group (P=0.031). The aRVEF and the overall ejection fraction decreased in the ASD group as compared with those in the normal control group (P=0.0005). The dynamic changes in the area of ASD and the motion curves for the right atrial volume and tricuspid annulus have the same dynamic characteristics. RT 3DE can be used to accurately evaluate the local and overall volume and functions of the right ventricle. The local and overall volume loads of the right ventricle in the ASD patients increase significantly as compared with those of the normal people. The right ventricular cardiac apex and the overall systolic function decrease.

  10. Cardiac Risk and Disordered Eating: Decreased R Wave Amplitude in Women with Bulimia Nervosa and Women with Subclinical Binge/Purge Symptoms.

    PubMed

    Green, Melinda; Rogers, Jennifer; Nguyen, Christine; Blasko, Katherine; Martin, Amanda; Hudson, Dominique; Fernandez-Kong, Kristen; Kaza-Amlak, Zauditu; Thimmesch, Brandon; Thorne, Tyler

    2016-11-01

    The purpose of the present study was threefold. First, we examined whether women with bulimia nervosa (n = 12) and women with subthreshold binge/purge symptoms (n = 20) showed decreased mean R wave amplitude, an indicator of cardiac risk, on electrocardiograph compared to asymptomatic women (n = 20). Second, we examined whether this marker was pervasive across experimental paradigms, including before and after sympathetic challenge tasks. Third, we investigated behavioural predictors of this marker, including binge frequency and purge frequency assessed by subtype (dietary restriction, excessive exercise, self-induced vomiting, and laxative abuse). Results of a 3 (ED symptom status) × 5 (experimental condition) mixed factorial ANCOVA (covariates: body mass index, age) indicated women with bulimia nervosa and women with subclinical binge/purge symptoms demonstrated significantly reduced mean R wave amplitude compared to asymptomatic women; this effect was pervasive across experimental conditions. Multiple regression analyses showed binge and purge behaviours, most notably laxative abuse as a purge method, predicted decreased R wave amplitude across all experimental conditions. Copyright © 2016 John Wiley & Sons, Ltd and Eating Disorders Association. Copyright © 2016 John Wiley & Sons, Ltd and Eating Disorders Association.

  11. Hyperkalemia masked by pseudo-stemi infarct pattern and cardiac arrest.

    PubMed

    Peerbhai, Shareez; Masha, Luke; DaSilva-DeAbreu, Adrian; Dhoble, Abhijeet

    2017-12-01

    Hyperkalemia is a common electrolyte abnormality and has well-recognized early electrocardiographic manifestations including PR prolongation and symmetric T wave peaking. With severe increase in serum potassium, dysrhythmias and atrioventricular and bundle branch blocks can be seen on electrocardiogram. Although cardiac arrest is a worrisome consequence of untreated hyperkalemia, rarely does hyperkalemia electrocardiographically manifest as acute ischemia. We present a case of acute renal failure complicated by malignant hyperkalemia and eventual ventricular fibrillation cardiac arrest. Recognition of this disorder was delayed secondary to an initial ECG pattern suggesting an acute ST segment elevation myocardial infarction (STEMI). Emergent coronary angiography performed showed no evidence of coronary artery disease. Pseudo-STEMI patterns are rarely seen in association with acute hyperkalemia and are most commonly described with patient without acute cardiac symptomatology. This is the first such case presenting concurrently with cardiac arrest. A brief review of this rare pseudo-infarct pattern is also given.

  12. Sarcomere mechanics in uniform and non-uniform cardiac muscle: a link between pump function and arrhythmias.

    PubMed

    ter Keurs, Henk E D J; Shinozaki, Tsuyoshi; Zhang, Ying Ming; Zhang, Mei Luo; Wakayama, Yuji; Sugai, Yoshinao; Kagaya, Yutaka; Miura, Masahito; Boyden, Penelope A; Stuyvers, Bruno D M; Landesberg, Amir

    2008-01-01

    Starling's Law and the well-known end-systolic pressure-volume relationship (ESPVR) of the left ventricle reflect the effect of sarcomere length (SL) on stress (sigma) development and shortening by myocytes in the uniform ventricle. We show here that tetanic contractions of rat cardiac trabeculae exhibit a sigma-SL relationship at saturating [Ca2+] that depends on sarcomere geometry in a manner similar to skeletal sarcomeres and the existence of opposing forces in cardiac muscle shortened below slack length. The sigma-SL-[Ca2+]free relationships (sigma-SL-CaR) at submaximal [Ca2+] in intact and skinned trabeculae were similar, albeit that the sensitivity for Ca2+ of intact muscle was higher. We analyzed the mechanisms underlying the sigma-SL-CaR using a kinetic model where we assumed that the rates of Ca2+ binding by Troponin-C (Tn-C) and/or cross-bridge (XB) cycling are determined by SL, [Ca2+] or stress. We analyzed the correlation between the model results and steady state stress measurements at varied SL and [Ca2+] from skinned rat cardiac trabeculae to test the hypotheses that: (i) the dominant feedback mechanism is SL, stress or [Ca2+]-dependent; and (ii) the feedback mechanism regulates: Tn-C-Ca2+ affinity, XB kinetics or, unitary XB-force. The analysis strongly suggests that feedback of the number of strong XBs to cardiac Tn-C-Ca2+ affinity is the dominant mechanism that regulates XB recruitment. Application of this concept in a mathematical model of twitch-stress accurately reproduced the sigma-SL-CaR and the time course of twitch-stress as well as the time course of intracellular [Ca2+]i. Modeling of the response of the cardiac twitch to rapid stress changes using the above feedback model uniquely predicted the occurrence of [Ca2+]i transients as a result of accelerated Ca2+ dissociation from Tn-C. The above concept has important repercussions for the non-uniformly contracting heart in which arrhythmogenic Ca2+ waves arise from weakened areas in cardiac muscle. These Ca2+ waves can reversibly be induced in muscle with non-uniform excitation contraction coupling (ECC) by the cycle of stretch and release in the border zone between the damaged and intact regions. Stimulus trains induced propagating Ca2+ waves and reversibly induced arrhythmias. We hypothesize that rapid force loss by sarcomeres in the border zone during relaxation causes Ca2+ release from Tn-C and initiates Ca2+ waves propagated by the sarcoplasmic reticulum (SR). These observations suggest the unifying hypothesis that force feedback to Ca2+ binding by Tn-C is responsible for Starling's Law and the ESPVR in uniform myocardium and leads in non-uniform myocardium to a surge of Ca2+ released by the myofilaments during relaxation, which initiates arrhythmogenic propagating Ca2+ release by the SR.

  13. Hemodynamics of the Aortic Jet and Implications for Detection of Aortic Stenosis Murmurs

    NASA Astrophysics Data System (ADS)

    Zhu, Chi; Seo, Junghee; Bakhshaee, Hani; Mittal, Rajat

    2016-11-01

    Cardiac auscultation with a stethoscope has served as the primary method for qualitative screening of cardiovascular conditions for over a hundred years. However, a lack of quantitative understanding of the flow mechanism(s) responsible for the generation of the murmurs, as well as the effect of intervening tissue on the propagation of these murmurs has been a significant limiting factor in the advancement of automated cardiac auscultation. In this study, a multiphysics computational modeling approach is used to investigate these issues. Direct numerical simulation (DNS) is used to explore the fluid dynamics of the jets formed at the aortic valve and the pressure fluctuations generated by the interaction of this jet with the aortic wall. Subsequently, structural wave propagation in the tissue is resolved by a high-order, linear viscoelastic wave solver in order to explore the propagation of the murmurs through a tissue-like material. The implications of these results for cardiac auscultation are discussed. The authors would like to acknowledge the financial support from NSF Grants IIS-1344772, CBET-1511200, and computational resource by XSEDE NSF Grant TG-CTS100002.

  14. The importance of mechano-electrical feedback and inertia in cardiac electromechanics.

    PubMed

    Costabal, Francisco Sahli; Concha, Felipe A; Hurtado, Daniel E; Kuhl, Ellen

    2017-06-15

    In the past years, a number cardiac electromechanics models have been developed to better understand the excitation-contraction behavior of the heart. However, there is no agreement on whether inertial forces play a role in this system. In this study, we assess the influence of mass in electromechanical simulations, using a fully coupled finite element model. We include the effect of mechano-electrical feedback via stretch activated currents. We compare five different models: electrophysiology, electromechanics, electromechanics with mechano-electrical feedback, electromechanics with mass, and electromechanics with mass and mechano-electrical feedback. We simulate normal conduction to study conduction velocity and spiral waves to study fibrillation. During normal conduction, mass in conjunction with mechano-electrical feedback increased the conduction velocity by 8.12% in comparison to the plain electrophysiology case. During the generation of a spiral wave, mass and mechano-electrical feedback generated secondary wavefronts, which were not present in any other model. These secondary wavefronts were initiated in tensile stretch regions that induced electrical currents. We expect that this study will help the research community to better understand the importance of mechanoelectrical feedback and inertia in cardiac electromechanics.

  15. Long-Term Continuous Ambulatory ECG Monitors and External Cardiac Loop Recorders for Cardiac Arrhythmia: A Health Technology Assessment

    PubMed Central

    Kabali, Conrad; Xie, Xuanqian; Higgins, Caroline

    2017-01-01

    Background Ambulatory electrocardiography (ECG) monitors are often used to detect cardiac arrhythmia. For patients with symptoms, an external cardiac loop recorder will often be recommended. The improved recording capacity of newer Holter monitors and similar devices, collectively known as longterm continuous ambulatory ECG monitors, suggests that they will perform just as well as, or better than, external loop recorders. This health technology assessment aimed to evaluate the effectiveness, cost-effectiveness, and budget impact of longterm continuous ECG monitors compared with external loop recorders in detecting symptoms of cardiac arrhythmia. Methods Based on our systematic search for studies published up to January 15, 2016, we did not identify any studies directly comparing the clinical effectiveness of longterm continuous ECG monitors and external loop recorders. Therefore, we conducted an indirect comparison, using a 24-hour Holter monitor as a common comparator. We used a meta-regression model to control for bias due to variation in device-wearing time and baseline syncope rate across studies. We conducted a similar systematic search for cost-utility and cost-effectiveness studies comparing the two types of devices; none were found. Finally, we used historical claims data (2006–2014) to estimate the future 5-year budget impact in Ontario, Canada, of continued public funding for both types of longterm ambulatory ECG monitors. Results Our clinical literature search yielded 7,815 non-duplicate citations, of which 12 cohort studies were eligible for indirect comparison. Seven studies assessed the effectiveness of longterm continuous monitors and five assessed external loop recorders. Both types of devices were more effective than a 24-hour Holter monitor, and we found no substantial difference between them in their ability to detect symptoms (risk difference 0.01; 95% confidence interval −0.18, 0.20). Using GRADE for network meta-analysis, we evaluated the quality of the evidence as low. Our budget impact analysis showed that use of the longterm continuous monitors has grown steadily in Ontario since they became publicly funded in 2006, particularly since 2011 when monitors that can record for 14 days or longer became funded, and the use of external cardiac loop recorders has correspondingly declined. The analysis suggests that, with these trends, continued public funding of both types of longterm ambulatory ECG testing will result in additional costs ranging from $130,000 to $370,000 per year over the next 5 years. Conclusions Although both longterm continuous ambulatory ECG monitors and external cardiac loop recorders were more effective than a 24-hour Holter monitor in detecting symptoms of cardiac arrhythmia, we found no evidence to suggest that these two devices differ in effectiveness. Assuming that the use of longterm continuous monitors will continue to increase in the next 5 years, the public health care system in Ontario can expect to see added costs of $130,000 to $370,000 per year. PMID:28194254

  16. A new cardiology patient simulator.

    PubMed

    Takashina, T; Shimizu, M; Katayama, H

    1997-01-01

    We report a new cardiology patient simulator developed through the application of new digital computer technology, capable of playing back selected physical findings (jugular-venous waves, arterial pulses of carotid, brachial, radial and femoral arteries, and cardiac impulses), as well as cardiac sounds, murmurs and respiratory sounds that have been prerecorded from actual patients. The examining physician uses an ordinary type of stethoscope. Four built-in speakers are located in the human-sized mannequin at the classic auscultatory sites (aortic, pulmonic, tricuspid and mitral). This compact and portable educational apparatus should facilitate medical training in the bedside cardiac examination, of physicians, medical students, nurses and paramedics throughout the world.

  17. Dynamics of Endo- and Epicardial Focal Fibrillation Waves at the Right Atrium in a Patient With Advanced Atrial Remodelling.

    PubMed

    van der Does, Lisette J M E; Kik, Charles; Bogers, Ad J J C; Allessie, Maurits A; de Groot, Natasja M S

    2016-10-01

    Focal waves appear frequently at the epicardium during persistent atrial fibrillation (AF), however, the origin of these waves is under debate. We performed simultaneous endo-epicardial mapping of the right atrial wall during longstanding persistent AF in a patient undergoing cardiac surgery. During 10 seconds 53 and 59 focal waves appeared at random at respectively the endocardium and epicardium. Repetitive focal activity did not last longer than 3 cycles. Transmural asynchrony and conduction might be the origin of focal waves. Asynchronous propagation of fibrillation waves in 3 dimensions would stabilize the arrhythmia and could explain the limited success of persistent AF ablation. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  18. Spiral-wave dynamics in a mathematical model of human ventricular tissue with myocytes and fibroblasts.

    PubMed

    Nayak, Alok Ranjan; Shajahan, T K; Panfilov, A V; Pandit, Rahul

    2013-01-01

    Cardiac fibroblasts, when coupled functionally with myocytes, can modulate the electrophysiological properties of cardiac tissue. We present systematic numerical studies of such modulation of electrophysiological properties in mathematical models for (a) single myocyte-fibroblast (MF) units and (b) two-dimensional (2D) arrays of such units; our models build on earlier ones and allow for zero-, one-, and two-sided MF couplings. Our studies of MF units elucidate the dependence of the action-potential (AP) morphology on parameters such as [Formula: see text], the fibroblast resting-membrane potential, the fibroblast conductance [Formula: see text], and the MF gap-junctional coupling [Formula: see text]. Furthermore, we find that our MF composite can show autorhythmic and oscillatory behaviors in addition to an excitable response. Our 2D studies use (a) both homogeneous and inhomogeneous distributions of fibroblasts, (b) various ranges for parameters such as [Formula: see text], and [Formula: see text], and (c) intercellular couplings that can be zero-sided, one-sided, and two-sided connections of fibroblasts with myocytes. We show, in particular, that the plane-wave conduction velocity [Formula: see text] decreases as a function of [Formula: see text], for zero-sided and one-sided couplings; however, for two-sided coupling, [Formula: see text] decreases initially and then increases as a function of [Formula: see text], and, eventually, we observe that conduction failure occurs for low values of [Formula: see text]. In our homogeneous studies, we find that the rotation speed and stability of a spiral wave can be controlled either by controlling [Formula: see text] or [Formula: see text]. Our studies with fibroblast inhomogeneities show that a spiral wave can get anchored to a local fibroblast inhomogeneity. We also study the efficacy of a low-amplitude control scheme, which has been suggested for the control of spiral-wave turbulence in mathematical models for cardiac tissue, in our MF model both with and without heterogeneities.

  19. Fast Acceleration of 2D Wave Propagation Simulations Using Modern Computational Accelerators

    PubMed Central

    Wang, Wei; Xu, Lifan; Cavazos, John; Huang, Howie H.; Kay, Matthew

    2014-01-01

    Recent developments in modern computational accelerators like Graphics Processing Units (GPUs) and coprocessors provide great opportunities for making scientific applications run faster than ever before. However, efficient parallelization of scientific code using new programming tools like CUDA requires a high level of expertise that is not available to many scientists. This, plus the fact that parallelized code is usually not portable to different architectures, creates major challenges for exploiting the full capabilities of modern computational accelerators. In this work, we sought to overcome these challenges by studying how to achieve both automated parallelization using OpenACC and enhanced portability using OpenCL. We applied our parallelization schemes using GPUs as well as Intel Many Integrated Core (MIC) coprocessor to reduce the run time of wave propagation simulations. We used a well-established 2D cardiac action potential model as a specific case-study. To the best of our knowledge, we are the first to study auto-parallelization of 2D cardiac wave propagation simulations using OpenACC. Our results identify several approaches that provide substantial speedups. The OpenACC-generated GPU code achieved more than speedup above the sequential implementation and required the addition of only a few OpenACC pragmas to the code. An OpenCL implementation provided speedups on GPUs of at least faster than the sequential implementation and faster than a parallelized OpenMP implementation. An implementation of OpenMP on Intel MIC coprocessor provided speedups of with only a few code changes to the sequential implementation. We highlight that OpenACC provides an automatic, efficient, and portable approach to achieve parallelization of 2D cardiac wave simulations on GPUs. Our approach of using OpenACC, OpenCL, and OpenMP to parallelize this particular model on modern computational accelerators should be applicable to other computational models of wave propagation in multi-dimensional media. PMID:24497950

  20. Prognostic implications of Q waves at presentation in patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention: An analysis of the HORIZONS-AMI study.

    PubMed

    Kosmidou, Ioanna; Redfors, Björn; Crowley, Aaron; Gersh, Bernard; Chen, Shmuel; Dizon, José M; Embacher, Monica; Mehran, Roxana; Ben-Yehuda, Ori; Mintz, Gary S; Stone, Gregg W

    2017-11-01

    Presence of Q waves on the presenting electrocardiogram (ECG) in patients with ST-segment elevation myocardial infarction (STEMI) has been associated with worse prognosis; however, whether the prognostic value of Q waves is influenced by baseline characteristics and/or rapidity of revascularization based on the guideline-based metric of door-to-balloon time remains unknown. We hypothesized that Q waves in the presenting ECG will be predictive of long term mortality regardless of time to reperfusion. The Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) trial enrolled 3602 patients with STEMI undergoing primary percutaneous coronary intervention. We stratified patients without prior history of myocardial infarction or coronary revascularization according to presence or absence of pathological Q waves on their presenting ECG. Associations between Q waves, death, and cardiovascular outcomes within 3 years were assessed using Cox proportional hazards regression. Among 2723 patients with evaluable ECGs, 1084 (39.8%) had Q waves on their presenting ECG. Male sex and time from symptom onset to balloon inflation were independent predictors of presence of Q waves. Patients with Q waves had higher adjusted risks of all-cause death (adjusted hazard ratio: 1.45, 95% confidence interval: 1.02-2.05, P = 0.04) and cardiac death (adjusted hazard ratio: 1.72, 95% confidence interval: 1.08-2.72, P = 0.02). The association between Q waves and cardiac death was consistent regardless of sex, diabetes status, target vessel, or door-to-balloon time (P interaction > 0.4 for all). Presence of Q waves on the presenting ECG in patients undergoing primary percutaneous coronary intervention due to STEMI is an independent predictor of mortality and adds prognostic value, regardless of sex or rapidity of revascularization. © 2017 Wiley Periodicals, Inc.

  1. Enzyme replacement therapy with agalsidase beta improves cardiac involvement in Fabry's disease.

    PubMed

    Spinelli, L; Pisani, A; Sabbatini, M; Petretta, M; Andreucci, M V; Procaccini, D; Lo Surdo, N; Federico, S; Cianciaruso, B

    2004-08-01

    Fabry's disease is an X-linked lysosomal storage disease caused by a deficiency of alpha-galactosidase that results in an accumulation of neutral glycosphingolipids throughout the body, including the cardiovascular system. Fabry cardiomyopathy, characterized by progressive severe concentric left ventricular (LV) hypertrophy, is very frequent and is the most important cause of death in affected patients. Enzyme replacement therapy (ERT) allows a specific treatment for this disease, however, there are very few data on the effectiveness of therapy on cardiac involvement. Nine patients with Fabry cardiac disease were studied on basal condition and after 6 and 12 months of treatment with algasidase beta (Fabrazyme). A complete clinical, electrocardiographic and echocardiographic evaluation was performed in all patients. Interpretable Doppler recordings of transmitral flow and pulmonary flow velocity curves were also acquired. At baseline, the patients with Fabry's disease had increased LV septum and posterior wall thickness, normal LV fractional shortening, LV ejection fraction, normal Doppler parameters of mitral inflow but a duration of pulmonary vein flow velocity wave exceeding that of the mitral wave at atrial systole. ERT did not affect heart rate and arterial pressure. LV internal diameters did not change, there was a slight but not significant decrease in the LV posterior wall thickening and a progressive decrease in the interventricular septum thickening (p < 0.025) and in LV mass (p < 0.001) The difference in duration between pulmonary vein flow velocity wave and mitral wave at atrial systole significantly decreased (p < 0.001). These results suggest that ERT in patients with Fabry cardiomyopathy is able to reduce the LV mass and ameliorate the LV stiffness. Copyright 2004 Blackwell Munksgaard

  2. A cardiac electrical activity model based on a cellular automata system in comparison with neural network model.

    PubMed

    Khan, Muhammad Sadiq Ali; Yousuf, Sidrah

    2016-03-01

    Cardiac Electrical Activity is commonly distributed into three dimensions of Cardiac Tissue (Myocardium) and evolves with duration of time. The indicator of heart diseases can occur randomly at any time of a day. Heart rate, conduction and each electrical activity during cardiac cycle should be monitor non-invasively for the assessment of "Action Potential" (regular) and "Arrhythmia" (irregular) rhythms. Many heart diseases can easily be examined through Automata model like Cellular Automata concepts. This paper deals with the different states of cardiac rhythms using cellular automata with the comparison of neural network also provides fast and highly effective stimulation for the contraction of cardiac muscles on the Atria in the result of genesis of electrical spark or wave. The specific formulated model named as "States of automaton Proposed Model for CEA (Cardiac Electrical Activity)" by using Cellular Automata Methodology is commonly shows the three states of cardiac tissues conduction phenomena (i) Resting (Relax and Excitable state), (ii) ARP (Excited but Absolutely refractory Phase i.e. Excited but not able to excite neighboring cells) (iii) RRP (Excited but Relatively Refractory Phase i.e. Excited and able to excite neighboring cells). The result indicates most efficient modeling with few burden of computation and it is Action Potential during the pumping of blood in cardiac cycle.

  3. Non-contact detection of cardiac rate based on visible light imaging device

    NASA Astrophysics Data System (ADS)

    Zhu, Huishi; Zhao, Yuejin; Dong, Liquan

    2012-10-01

    We have developed a non-contact method to detect human cardiac rate at a distance. This detection is based on the general lighting condition. Using the video signal of human face region captured by webcam, we acquire the cardiac rate based on the PhotoPlethysmoGraphy theory. In this paper, the cardiac rate detecting method is mainly in view of the blood's different absorptivities of the lights various wavelengths. Firstly, we discompose the video signal into RGB three color signal channels and choose the face region as region of interest to take average gray value. Then, we draw three gray-mean curves on each color channel with time as variable. When the imaging device has good fidelity of color, the green channel signal shows the PhotoPlethysmoGraphy information most clearly. But the red and blue channel signals can provide more other physiological information on the account of their light absorptive characteristics of blood. We divide red channel signal by green channel signal to acquire the pulse wave. With the passband from 0.67Hz to 3Hz as a filter of the pulse wave signal and the frequency spectrum superimposed algorithm, we design frequency extracted algorithm to achieve the cardiac rate. Finally, we experiment with 30 volunteers, containing different genders and different ages. The results of the experiments are all relatively agreeable. The difference is about 2bmp. Through the experiment, we deduce that the PhotoPlethysmoGraphy theory based on visible light can also be used to detect other physiological information.

  4. [Bayes' syndrome in cardiac surgery: prevalence of interatrial block in patients younger than 65 years undergoing cardiac surgery and association with postoperative atrial fibrillation].

    PubMed

    García-Izquierdo Jaén, Eusebio; Cobo Rodríguez, Pablo; Solís Solís, Luis; Pham Trung, Chinh; Jiménez Sánchez, Diego; Sánchez García, Manuel; Castro Urda, Victor; Toquero Ramos, Jorge; Fernández Lozano, Ignacio

    2017-11-03

    Interatrial block (IAB) is a well-known entity that is associated with an increased risk of atrial fibrillation (AF). This association is called Bayes' syndrome. The aim of our study was to define the prevalence of IAB among patients younger than 65 years undergoing cardiac surgery and determine whether there is an association between the presence of interatrial conduction delay and postoperative atrial fibrillation (POAF). A total of 207 patients were enrolled. Partial IAB was defined as P-wave>120ms. Advanced IAB was defined as P-wave>120ms+biphasic morphology in the inferior leads. Ocurrence of POAF was assessed and a comparative analysis was conducted between patients that did and did not develop AF. IAB prevalence was 78.3% (partial 66.2%, advanced 12.1%). POAF occurred in 28.5% of all patients, and was more frequent among patients with advanced IAB (44%) compared to 27.7% and 24.4% of POAF among patients with partial IAB and without IAB, respectively. Patients who developed POAF were significantly older, had significantly higher NTproBNP, higher prevalence of atrial enlargement and thyroid disease. After multivariate analysis, advanced IAB was found to be independently associated with POAF. IAB is a frequent finding among patients undergoing cardiac surgery. According to our results, advanced IAB is independently associated with POAF in younger patients (<65 years) undergoing cardiac surgery. Copyright © 2017 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.

  5. FloWave.US: validated, open-source, and flexible software for ultrasound blood flow analysis.

    PubMed

    Coolbaugh, Crystal L; Bush, Emily C; Caskey, Charles F; Damon, Bruce M; Towse, Theodore F

    2016-10-01

    Automated software improves the accuracy and reliability of blood velocity, vessel diameter, blood flow, and shear rate ultrasound measurements, but existing software offers limited flexibility to customize and validate analyses. We developed FloWave.US-open-source software to automate ultrasound blood flow analysis-and demonstrated the validity of its blood velocity (aggregate relative error, 4.32%) and vessel diameter (0.31%) measures with a skeletal muscle ultrasound flow phantom. Compared with a commercial, manual analysis software program, FloWave.US produced equivalent in vivo cardiac cycle time-averaged mean (TAMean) velocities at rest and following a 10-s muscle contraction (mean bias <1 pixel for both conditions). Automated analysis of ultrasound blood flow data was 9.8 times faster than the manual method. Finally, a case study of a lower extremity muscle contraction experiment highlighted the ability of FloWave.US to measure small fluctuations in TAMean velocity, vessel diameter, and mean blood flow at specific time points in the cardiac cycle. In summary, the collective features of our newly designed software-accuracy, reliability, reduced processing time, cost-effectiveness, and flexibility-offer advantages over existing proprietary options. Further, public distribution of FloWave.US allows researchers to easily access and customize code to adapt ultrasound blood flow analysis to a variety of vascular physiology applications. Copyright © 2016 the American Physiological Society.

  6. Investigation of a continuous heating/cooling technique for cardiac output measurement.

    PubMed

    Ehlers, K C; Mylrea, K C; Calkins, J M

    1987-01-01

    Cardiac output is frequently measured to assess patient hemodynamic status in the operating room and intensive care unit. Current research for measuring cardiac output includes continuous sinusoidal heating and synchronous detection of thermal signals. This technique is limited by maximum heating element temperatures and background thermal noise. A continuous heating and cooling technique was investigated in vitro to determine if greater thermal signal magnitudes could be obtained. A fast responding thermistor was employed to measure consecutive ejected temperature plateaus in the thermal signal. A flow bath and mechanical ventricle were used to simulate the cardiovascular system. A thermoelectric module was used to apply heating and cooling energy to the flow stream. Trials encompassing a range of input power, input frequency, and flow rate were conducted. By alternating heating and cooling, thermal signal magnitude can be increased when compared to continuous heating alone. However, the increase was not sufficient to allow for recording in all patients over the expected normal range of cardiac output. Consecutive ejected temperature plateaus were also measured on the thermal signal and ejection fraction calculations were made.

  7. A contactless approach for respiratory gating in PET using continuous-wave radar

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ersepke, Thomas, E-mail: Thomas.Ersepke@rub.de; Büther, Florian; Heß, Mirco

    Purpose: Respiratory gating is commonly used to reduce motion artifacts in positron emission tomography (PET). Clinically established methods for respiratory gating in PET require contact to the patient or a direct optical line between the sensor and the patient’s torso and time consuming preparation. In this work, a contactless method for capturing a respiratory signal during PET is presented based on continuous-wave radar. Methods: The proposed method relies on the principle of emitting an electromagnetic wave and detecting the phase shift of the reflected wave, modulated due to the respiratory movement of the patient’s torso. A 24 GHz carrier frequencymore » was chosen allowing wave propagation through plastic and clothing with high reflections at the skin surface. A detector module and signal processing algorithms were developed to extract a quantitative respiratory signal. The sensor was validated using a high precision linear table. During volunteer measurements and [{sup 18}F] FDG PET scans, the radar sensor was positioned inside the scanner bore of a PET/computed tomography scanner. As reference, pressure belt (one volunteer), depth camera-based (two volunteers, two patients), and PET data-driven (six patients) signals were acquired simultaneously and the signal correlation was quantified. Results: The developed system demonstrated a high measurement accuracy for movement detection within the submillimeter range. With the proposed method, small displacements of 25 μm could be detected, not considerably influenced by clothing or blankets. From the patient studies, the extracted respiratory radar signals revealed high correlation (Pearson correlation coefficient) to those derived from the external pressure belt and depth camera signals (r = 0.69–0.99) and moderate correlation to those of the internal data-driven signals (r = 0.53–0.70). In some cases, a cardiac signal could be visualized, due to the representation of the mechanical heart motion on the skin. Conclusions: Accurate respiratory signals were obtained successfully by the proposed method with high spatial and temporal resolution. By working without contact and passing through clothing and blankets, this approach minimizes preparation time and increases the convenience of the patient during the scan.« less

  8. "J waves" induced after short coupling intervals: a manifestations of latent depolarization abnormality?

    PubMed

    Aizawa, Yoshifusa; Nakayama, Masafumi; Sato, Masahito; Okabe, Masaaki; Aizawa, Yoshiyasu; Takatsuki, Seiji; Fukuda, Keiichi

    2017-04-24

    To confirm the presence of tachycardia-induced slur or notch in the terminal portion of the QRS complexes in a general patient population. A tachycardia-induced J wave was defined as a slur or notch in the terminal portion of the QRS complexes newly induced at short RR intervals during atrial premature contractions (APCs) or atrial electrical stimulation in the electrophysiological study (EPS). Twenty-three out of 2000 patients with general diseases were involved. All patients with aborted sudden cardiac death, ventricular fibrillation or a family history of sudden cardiac death were excluded. The mean age was 72 ± 9 years, and 11 patients were male (47.8%). When the RR interval was shortened from 821 ± 142 ms to 464 ± 52 ms in the conducted APCs (P < 0.0001), J waves became diagnostic (0.02 ± 0.03 mV to 0.20 ± 0.07 mV, P < 0.0001). J waves were confined to the inferior leads in 22 (95.7%) patients and were notched in 11 (47.8%) and slurred in 12 (52.2%) patients. The induction of J waves was accompanied by visible changes of the QRS morphology. When the post-APC RR interval was prolonged to 992 ± 305 ms (P = 0.0154 vs. baseline), the J waves were similar to baseline levels. During the EPS, J wave induction was confirmed during atrial stimulation. There were no characteristic clinical or ECG features in the patients with tachycardia-induced J waves. J waves can be newly induced by short RR intervals in a general patient population, and a conduction delay is the likely mechanism causing such J waves. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For Permissions, please email: journals.permissions@oup.com.

  9. Coronary wave energy: a novel predictor of functional recovery after myocardial infarction.

    PubMed

    De Silva, Kalpa; Foster, Paul; Guilcher, Antoine; Bandara, Asela; Jogiya, Roy; Lockie, Tim; Chowiencyzk, Phil; Nagel, Eike; Marber, Michael; Redwood, Simon; Plein, Sven; Perera, Divaka

    2013-04-01

    Revascularization after acute coronary syndromes provides prognostic benefit, provided that the subtended myocardium is viable. The microcirculation and contractility of the subtended myocardium affect propagation of coronary flow, which can be characterized by wave intensity analysis. The study objective was to determine in acute coronary syndromes whether early wave intensity analysis-derived microcirculatory (backward) expansion wave energy predicts late viability, defined by functional recovery. Thirty-one patients (58±11 years) were enrolled after non-ST elevation myocardial infarction. Regional left ventricular function and late-gadolinium enhancement were assessed by cardiac magnetic resonance imaging, before and 3 months after revascularization. The backward-traveling (microcirculatory) expansion wave was derived from wave intensity analysis of phasic coronary pressure and velocity in the infarct-related artery, whereas mean values were used to calculate hyperemic microvascular resistance. Twelve-hour troponin T, left ventricular ejection fraction, and percentage late-gadolinium enhancement mass were 1.35±1.21 µg/L, 56±11%, and 8.4±6.0%, respectively. The infarct-related artery backward-traveling (microcirculatory) expansion wave was inversely correlated with late-gadolinium enhancement infarct mass (r=-0.81; P<0.0001) and strongly predicted regional left ventricular recovery (r=0.68; P=0.001). By receiver operating characteristic analysis, a backward-traveling (microcirculatory) expansion wave threshold of 2.8 W m(-2) s(-2)×10(5) predicted functional recovery with sensitivity and specificity of 0.91 and 0.82 (AUC 0.88). Hyperemic microvascular resistance correlated with late-gadolinium enhancement mass (r=0.48; P=0.03) but not left ventricular recovery (r=-0.34; P=0.07). The microcirculation-derived backward expansion wave is a new index that correlates with the magnitude and location of infarction, which may allow for the prediction of functional myocardial recovery. Coronary wave intensity analysis may facilitate myocardial viability assessment during cardiac catheterization.

  10. Features of Chaotic Transients in Excitable Media Governed by Spiral and Scroll Waves

    NASA Astrophysics Data System (ADS)

    Lilienkamp, Thomas; Christoph, Jan; Parlitz, Ulrich

    2017-08-01

    In excitable media, chaotic dynamics governed by spiral or scroll waves is often not persistent but transient. Using extensive simulations employing different mathematical models we identify a specific type-II supertransient by an exponential increase of transient lifetimes with the system size in 2D and an investigation of the dynamics (number and lifetime of spiral waves, Kaplan-Yorke dimension). In 3D, simulations exhibit an increase of transient lifetimes and filament lengths only above a critical thickness. Finally, potential implications for understanding cardiac arrhythmias are discussed.

  11. Smoking Cessation in Cardiac Patients: The Influence of Action Plans, Coping Plans and Self-Efficacy on Quitting Smoking

    ERIC Educational Resources Information Center

    de Hoog, Natascha; Bolman, Catherine; Berndt, Nadine; Kers, Esther; Mudde, Aart; de Vries, Hein; Lechner, Lilian

    2016-01-01

    Smoking cessation is the most effective action for cardiac patients who smoke to improve their prognosis, yet more than one-half of cardiac patients continue to smoke after hospital admission. This study examined the influence of action plans, coping plans and self-efficacy on intention to quit and smoking cessation in cardiac patients. Cardiac…

  12. The Effect of Aortic Compliance on Left Ventricular Power Requirement

    NASA Astrophysics Data System (ADS)

    Pahlevan, Niema; Gharib, Morteza

    2009-11-01

    Aortic compliance depends on both geometry and mechanical properties of the aorta. Reduction in arterial compliance has been associated with aging, smoking, and multiple cardiovascular diseases. Increased stiffness of the aorta affects the wave dynamics in the aorta by increasing both pulse pressure amplitude and wave speed. We hypothesized that decreased aortic compliance leads to an increased left ventricular power requirement for a fixed cardiac output due to altered pulse pressure and pulse wave velocity. We used a computational approach using the finite element method for solid and fluid domains coupled to each other by using the direct coupling method. A nonlinear material model was used for the solid wall. The fluid flow model was considered to be Newtonian, incompressible, and laminar. The simulation was performed for a heart rate of 75 beats per minute for six different compliances while keeping the cardiac output and the peripheral resistance constant. The results show a trend towards increased left ventricular energy expenditure per cycle with decreased compliance. The relevance of these findings to clinical observations will be discussed.

  13. The effect of traditional Persian music on the cardiac functioning of young Iranian women.

    PubMed

    Abedi, Behzad; Abbasi, Ataollah; Goshvarpour, Atefeh; Khosroshai, Hamid Tayebi; Javanshir, Elnaz

    In the past few decades, several studies have reported the physiological effects of listening to music. The physiological effects of different music types on different people are not similar. Therefore, in the present study, we have sought to examine the effects of traditional Persian music on the cardiac function in young women. Twenty-two healthy females participated in this study. ECG signals were recorded in two conditions: rest and music. For each of the 21 ECG signals (15 morphological and six wavelet based feature) features were extracted. SVM classifier was used for the classification of ECG signals during and before the music. The results showed that the mean of heart rate, the mean amplitude of R-wave, T-wave, and P-wave decreased in response to music. Time-frequency analysis revealed that the mean of the absolute values of the detail coefficients at higher scales increased during rest. The overall accuracy of 91.6% was achieved using polynomial kernel and RBF kernel. Using linear kernel, the best result (with the accuracy rate of 100%) was attained. Copyright © 2016. Published by Elsevier B.V.

  14. Reflective lens-free imaging on high-density silicon microelectrode arrays for monitoring and evaluation of in vitro cardiac contractility

    PubMed Central

    Pauwelyn, Thomas; Stahl, Richard; Mayo, Lakyn; Zheng, Xuan; Lambrechts, Andy; Janssens, Stefan; Lagae, Liesbet; Reumers, Veerle; Braeken, Dries

    2018-01-01

    The high rate of drug attrition caused by cardiotoxicity is a major challenge for drug development. Here, we developed a reflective lens-free imaging (RLFI) approach to non-invasively record in vitro cell deformation in cardiac monolayers with high temporal (169 fps) and non-reconstructed spatial resolution (352 µm) over a field-of-view of maximally 57 mm2. The method is compatible with opaque surfaces and silicon-based devices. Further, we demonstrated that the system can detect the impairment of both contractility and fast excitation waves in cardiac monolayers. Additionally, the RLFI device was implemented on a CMOS-based microelectrode array to retrieve multi-parametric information of cardiac cells, thereby offering more in-depth analysis of drug-induced (cardiomyopathic) effects for preclinical cardiotoxicity screening applications. PMID:29675322

  15. Discordant U waves in the setting of hyperkalaemia.

    PubMed

    Chhabra, Lovely; Spodick, David H

    2013-07-04

    Physiological U wave genesis occurs likely secondary to either late repolarisation of Purkinje fibres, or late repolarisation of some myocardial cells and/or delayed after depolarisation of the ventricular wall occurring during ventricular filling. Hypokalaemia has a well-known association with pathological 'U wave' which actually combines with the T wave (TU complex) and results from slowing of phase 3 of the action potential with resultant electrical interaction between the three myocardial layers. U waves usually tend to disappear in the setting of hyperkalaemia. We report an unusual case where hyperkalaemia and discordant U waves coexisted. We believe that this may have occurred as a result of partial clinical adaptation of cardiac myocytes to the long-standing effects of hyperkalaemia as the patient had underlying history of chronic kidney disease. We also discuss the possible mechanisms of the U wave genesis and the importance of different U wave morphologies encountered in the real clinical practice.

  16. Tracking brain motion during the cardiac cycle using spiral cine-DENSE MRI

    PubMed Central

    Zhong, Xiaodong; Meyer, Craig H.; Schlesinger, David J.; Sheehan, Jason P.; Epstein, Frederick H.; Larner, James M.; Benedict, Stanley H.; Read, Paul W.; Sheng, Ke; Cai, Jing

    2009-01-01

    Cardiac-synchronized brain motion is well documented, but the accurate measurement of such motion on the pixel-by-pixel basis has been hampered by the lack of proper imaging technique. In this article, the authors present the implementation of an autotracking spiral cine displacement-encoded stimulation echo (DENSE) magnetic resonance imaging (MRI) technique for the measurement of pulsatile brain motion during the cardiac cycle. Displacement-encoded dynamic MR images of three healthy volunteers were acquired throughout the cardiac cycle using the spiral cine-DENSE pulse sequence gated to the R wave of an electrocardiogram. Pixelwise Lagrangian displacement maps were computed, and 2D displacement as a function of time was determined for selected regions of interests. Different intracranial structures exhibited characteristic motion amplitude, direction, and pattern throughout the cardiac cycle. Time-resolved displacement curves revealed the pathway of pulsatile motion from brain stem to peripheral brain lobes. These preliminary results demonstrated that the spiral cine-DENSE MRI technique can be used to measure cardiac-synchronized pulsatile brain motion on the pixel-by-pixel basis with high temporal∕spatial resolution and sensitivity. PMID:19746774

  17. The Generation and Propagation of Arterial Murmurs from a Stenosed Artery: A Computational Study

    NASA Astrophysics Data System (ADS)

    Zhu, Chi; Seo, Jung-Hee; Bakhshaee, Hani; Mittal, Rajat

    2015-11-01

    Cardiac auscultation - the procedure of diagnosing cardiovascular conditions using the stethoscope - has been used effectively for over a hundred years but still, the flow mechanism(s) responsible for the generation of these murmurs, as well as the effect of intervening tissue on the propagation of these murmurs, is not well understood. In this study, a one-way coupled, hybrid approach is used to investigate the propagation of murmurs generated from the flow in a stenosed artery. Specifically, the flow in the modeled artery is solved by an incompressible Navier-Stokes solver with the immersed-boundary method. The structural wave propagation in the tissue is resolved by a high-order, linear viscoelastic wave solver, and a mathematical decomposition is applied to separate the compressional and shear component of the acoustic wave propagating through the tissue. The simulations suggest, somewhat counterintuitively, that the shear wave contributes a significant component to the signal picked up by a stethoscope, and that this component carries much of the information that characterizes the source of the murmur. The implications of this for cardiac auscultation and further modeling of hemoacoustics are discussed. The effect of the stenosis severity and the flow pulsatility will also be investigated. The authors would like to acknowledge the SCH for funding this project.

  18. Orthostatic intolerance and motion sickness after parabolic flight

    NASA Technical Reports Server (NTRS)

    Schlegel, T. T.; Brown, T. E.; Wood, S. J.; Benavides, E. W.; Bondar, R. L.; Stein, F.; Moradshahi, P.; Harm, D. L.; Fritsch-Yelle, J. M.; Low, P. A.

    2001-01-01

    Because it is not clear that the induction of orthostatic intolerance in returning astronauts always requires prolonged exposure to microgravity, we investigated orthostatic tolerance and autonomic cardiovascular function in 16 healthy subjects before and after the brief micro- and hypergravity of parabolic flight. Concomitantly, we investigated the effect of parabolic flight-induced vomiting on orthostatic tolerance, R-wave-R-wave interval and arterial pressure power spectra, and carotid-cardiac baroreflex and Valsalva responses. After parabolic flight 1) 8 of 16 subjects could not tolerate 30 min of upright tilt (compared to 2 of 16 before flight); 2) 6 of 16 subjects vomited; 3) new intolerance to upright tilt was associated with exaggerated falls in total peripheral resistance, whereas vomiting was associated with increased R-wave-R-wave interval variability and carotid-cardiac baroreflex responsiveness; and 4) the proximate mode of new orthostatic failure differed in subjects who did and did not vomit, with vomiters experiencing comparatively isolated upright hypocapnia and cerebral vasoconstriction and nonvomiters experiencing signs and symptoms reminiscent of the clinical postural tachycardia syndrome. Results suggest, first, that syndromes of orthostatic intolerance resembling those developing after space flight can develop after a brief (i.e., 2-h) parabolic flight and, second, that recent vomiting can influence the results of tests of autonomic cardiovascular function commonly utilized in returning astronauts.

  19. Device for rapid quantification of human carotid baroreceptor-cardiac reflex responses

    NASA Technical Reports Server (NTRS)

    Sprenkle, J. M.; Eckberg, D. L.; Goble, R. L.; Schelhorn, J. J.; Halliday, H. C.

    1986-01-01

    A new device has been designed, constructed, and evaluated to characterize the human carotid baroreceptor-cardiac reflex response relation rapidly. This system was designed for study of reflex responses of astronauts before, during, and after space travel. The system comprises a new tightly sealing silicon rubber neck chamber, a stepping motor-driven electrodeposited nickel bellows pressure system, capable of delivering sequential R-wave-triggered neck chamber pressure changes between +40 and -65 mmHg, and a microprocessor-based electronics system for control of pressure steps and analysis and display of responses. This new system provokes classic sigmoid baroreceptor-cardiac reflex responses with threshold, linear, and saturation ranges in most human volunteers during one held expiration.

  20. A Fast Multimodal Ectopic Beat Detection Method Applied for Blood Pressure Estimation Based on Pulse Wave Velocity Measurements in Wearable Sensors.

    PubMed

    Pflugradt, Maik; Geissdoerfer, Kai; Goernig, Matthias; Orglmeister, Reinhold

    2017-01-14

    Automatic detection of ectopic beats has become a thoroughly researched topic, with literature providing manifold proposals typically incorporating morphological analysis of the electrocardiogram (ECG). Although being well understood, its utilization is often neglected, especially in practical monitoring situations like online evaluation of signals acquired in wearable sensors. Continuous blood pressure estimation based on pulse wave velocity considerations is a prominent example, which depends on careful fiducial point extraction and is therefore seriously affected during periods of increased occurring extrasystoles. In the scope of this work, a novel ectopic beat discriminator with low computational complexity has been developed, which takes advantage of multimodal features derived from ECG and pulse wave relating measurements, thereby providing additional information on the underlying cardiac activity. Moreover, the blood pressure estimations' vulnerability towards ectopic beats is closely examined on records drawn from the Physionet database as well as signals recorded in a small field study conducted in a geriatric facility for the elderly. It turns out that a reliable extrasystole identification is essential to unsupervised blood pressure estimation, having a significant impact on the overall accuracy. The proposed method further convinces by its applicability to battery driven hardware systems with limited processing power and is a favorable choice when access to multimodal signal features is given anyway.

  1. Manifestation of J wave induced by acetylcholine applied for a coronary spasm provocation test in a patient with aborted sudden cardiac death.

    PubMed

    Kodama, Hiroyuki; Fujita, Kazumasa; Moriyama, Shouhei; Irie, Kei; Noda, Hirotaka; Yokoyama, Taku; Fukata, Mitsuhiro; Arita, Takeshi; Odashiro, Keita; Maruyama, Toru; Akashi, Koichi

    2017-06-01

    A 51-year-old man with a resuscitation episode was referred to our hospital. Coronary angiography revealed a focal spasm overlapped with organic stenosis where a bare metal stent was implanted. Acetylcholine (ACh) provocation test did not induce chest pain. It revealed no discernible ST-T changes but unmasked a J wave at the end of the QRS complex, which was associated with short-coupled repetitive premature ventricular beats. A J wave reportedly appears immediately before the onset of ventricular fibrillation caused by vasospastic angina. However, a J wave observed newly after a coronary spasm provocation test using ACh without ST-T changes is informative when considering the mechanisms of the J wave.

  2. Mathematical Models of Cardiac Pacemaking Function

    NASA Astrophysics Data System (ADS)

    Li, Pan; Lines, Glenn T.; Maleckar, Mary M.; Tveito, Aslak

    2013-10-01

    Over the past half century, there has been intense and fruitful interaction between experimental and computational investigations of cardiac function. This interaction has, for example, led to deep understanding of cardiac excitation-contraction coupling; how it works, as well as how it fails. However, many lines of inquiry remain unresolved, among them the initiation of each heartbeat. The sinoatrial node, a cluster of specialized pacemaking cells in the right atrium of the heart, spontaneously generates an electro-chemical wave that spreads through the atria and through the cardiac conduction system to the ventricles, initiating the contraction of cardiac muscle essential for pumping blood to the body. Despite the fundamental importance of this primary pacemaker, this process is still not fully understood, and ionic mechanisms underlying cardiac pacemaking function are currently under heated debate. Several mathematical models of sinoatrial node cell membrane electrophysiology have been constructed as based on different experimental data sets and hypotheses. As could be expected, these differing models offer diverse predictions about cardiac pacemaking activities. This paper aims to present the current state of debate over the origins of the pacemaking function of the sinoatrial node. Here, we will specifically review the state-of-the-art of cardiac pacemaker modeling, with a special emphasis on current discrepancies, limitations, and future challenges.

  3. Mechanism linking T-wave alternans to the genesis of cardiac fibrillation.

    PubMed

    Pastore, J M; Girouard, S D; Laurita, K R; Akar, F G; Rosenbaum, D S

    1999-03-16

    Although T-wave alternans has been closely associated with vulnerability to ventricular arrhythmias, the cellular processes underlying T-wave alternans and their role, if any, in the mechanism of reentry remain unclear. -T-wave alternans on the surface ECG was elicited in 8 Langendorff-perfused guinea pig hearts during fixed-rate pacing while action potentials were recorded simultaneously from 128 epicardial sites with voltage-sensitive dyes. Alternans of the repolarization phase of the action potential was observed above a critical threshold heart rate (HR) (209+/-46 bpm) that was significantly lower (by 57+/-36 bpm) than the HR threshold for alternation of action potential depolarization. The magnitude (range, 2.7 to 47.0 mV) and HR threshold (range, 171 to 272 bpm) of repolarization alternans varied substantially between cells across the epicardial surface. T-wave alternans on the surface ECG was explained primarily by beat-to-beat alternation in the time course of cellular repolarization. Above a critical HR, membrane repolarization alternated with the opposite phase between neighboring cells (ie, discordant alternans), creating large spatial gradients of repolarization. In the presence of discordant alternans, a small acceleration of pacing cycle length produced a characteristic sequence of events: (1) unidirectional block of an impulse propagating against steep gradients of repolarization, (2) reentrant propagation, and (3) the initiation of ventricular fibrillation. Repolarization alternans at the level of the single cell accounts for T-wave alternans on the surface ECG. Discordant alternans produces spatial gradients of repolarization of sufficient magnitude to cause unidirectional block and reentrant ventricular fibrillation. These data establish a mechanism linking T-wave alternans of the ECG to the pathogenesis of sudden cardiac death.

  4. Cardiac magnetic resonance in myocardial disease.

    PubMed

    Sechtem, U; Mahrholdt, H; Vogelsberg, H

    2007-12-01

    For a number of patients it is difficult to diagnose the cause of cardiac disease. In such patients cardiac magnetic resonance is useful for helping to make a differential diagnosis between ischaemic and dilated cardiomyopathy; identifying patients with myocarditis; diagnosing cardiac involvement in sarcoidosis and Chagas' disease; identifying patients with unusual forms of hypertrophic cardiomyopathy and those with continuing myocardial damage; and defining the sequelae of ablation treatment for hypertrophic obstructive cardiomyopathy.

  5. Effects of psychological stress test on the cardiac response of public safety workers: alternative parameters to autonomic balance

    NASA Astrophysics Data System (ADS)

    Huerta-Franco, M. R.; Vargas-Luna, F. M.; Delgadillo-Holtfort, I.

    2015-01-01

    It is well known that public safety workers (PSW) face many stressful situations that yield them as high-risk population for suffering chronic stress diseases. In this multidisciplinary research the cardiac response to induced psychological stress by a short duration Stroop test was evaluated in 20 female and 19 male PSW, in order to compare traditionally used cardiac response parameters with alternative ones. Electrocardiograms have been recorded using the Eindhoven electrodes configuration for 1 min before, 3 min during and 1 min after the test. Signals analysis has been performed for the heart rate and the power spectra of its variability and of the variability of the amplitude of the R-wave, i.e. the highest peak of the electrocardiographic signal periodic sequence. The results demonstrated that the traditional autonomic balance index shows no significant differences between stages. In contrast, the median of the area of the power spectrum of the R-wave amplitude variability in the frequency region dominated by the autonomous nervous system (0.04-to-0.4 Hz) is the more sensitive parameter. Moreover, this parameter allows to identify gender differences consistent with those encountered in other studies.

  6. Theoretical considerations for mapping activation in human cardiac fibrillation

    NASA Astrophysics Data System (ADS)

    Rappel, Wouter-Jan; Narayan, Sanjiv M.

    2013-06-01

    Defining mechanisms for cardiac fibrillation is challenging because, in contrast to other arrhythmias, fibrillation exhibits complex non-repeatability in spatiotemporal activation but paradoxically exhibits conserved spatial gradients in rate, dominant frequency, and electrical propagation. Unlike animal models, in which fibrillation can be mapped at high spatial and temporal resolution using optical dyes or arrays of contact electrodes, mapping of cardiac fibrillation in patients is constrained practically to lower resolutions or smaller fields-of-view. In many animal models, atrial fibrillation is maintained by localized electrical rotors and focal sources. However, until recently, few studies had revealed localized sources in human fibrillation, so that the impact of mapping constraints on the ability to identify rotors or focal sources in humans was not described. Here, we determine the minimum spatial and temporal resolutions theoretically required to detect rigidly rotating spiral waves and focal sources, then extend these requirements for spiral waves in computer simulations. Finally, we apply our results to clinical data acquired during human atrial fibrillation using a novel technique termed focal impulse and rotor mapping (FIRM). Our results provide theoretical justification and clinical demonstration that FIRM meets the spatio-temporal resolution requirements to reliably identify rotors and focal sources for human atrial fibrillation.

  7. A novel handheld device for use in remote patient monitoring of heart failure patients--design and preliminary validation on healthy subjects.

    PubMed

    Pollonini, Luca; Rajan, Nithin O; Xu, Shuai; Madala, Sridhar; Dacso, Clifford C

    2012-04-01

    Remote patient monitoring (RPM) holds great promise for reducing the burden of congestive heart failure (CHF). Improved sensor technology and effective predictive algorithms can anticipate sudden decompensation events. Enhanced telemonitoring systems would promote patient independence and facilitate communication between patients and their physicians. We report the development of a novel hand-held device, called Blue Box, capable of collecting and wirelessly transmitting key cardiac parameters derived from three integrated biosensors: 2 lead electrocardiogram (ECG), photoplethysmography and bioelectrical impedance (bioimpedance). Blue Box measurements include time intervals between consecutive ECG R-waves (RR interval), time duration of the ECG complex formed by the Q, R and S waves (QRS duration), bioimpedance, heart rate and systolic time intervals. In this study, we recruited 24 healthy subjects to collect several parameters measured by Blue Box and assess their value in correlating with cardiac output measured with Echo-Doppler. Linear correlation between the heart rate measured with Blue Box and cardiac output from Echo-Doppler had a group average correlation coefficient of 0.80. We found that systolic time intervals did not improve the model significantly. However, STIs did inversely correlate with increasing workloads.

  8. Persistent T-wave inversion predicts myocardial damage after ST-elevation myocardial infarction.

    PubMed

    Reindl, Martin; Reinstadler, Sebastian Johannes; Feistritzer, Hans-Josef; Niess, Lea; Koch, Constantin; Mayr, Agnes; Klug, Gert; Metzler, Bernhard

    2017-08-15

    Persistent T-wave inversion (PTI) after ST-elevation myocardial infarction (STEMI) is associated with worse clinical outcome; however, the underlying mechanism between PTI and poor prognosis is incompletely understood. We sought to investigate the relationship between PTI and myocardial damage assessed by cardiac magnetic resonance (CMR) following STEMI. In this prospective observational study, we included 142 consecutive revascularized STEMI patients. Electrocardiography to determine the presence and amplitude of PTI and pathological Q-waves was conducted 4months after infarction. CMR was performed within 1week after infarction and at 4months follow-up to evaluate infarct characteristics and myocardial function. Patients with PTI (n=103, 73%) showed a larger acute (21[11-29] vs. 6[1-13]%; p<0.001) and chronic infarct size (IS) (14[8-19] vs. 3[1-8]%; p<0.001) and more frequently microvascular obstruction (59 vs. 33%; p=0.02). The association between PTI and chronic IS remained significant (odds ratio: 9.02, 95%CI 3.49-23.35; p<0.001) after adjustment for pathological Q-wave and other IS estimators (high-sensitivity cardiac troponin T and C-reactive protein, N-terminal pro B-type natriuretic peptide, culprit vessel, pre-interventional TIMI flow). The value of PTI amplitude for the prediction of large chronic IS>11% (AUC: 0.84, 95%CI 0.77-0.90) was significantly higher compared to Q-wave amplitude (AUC: 0.72, 95%CI 0.63-0.80; p=0.009); the combination of PTI with pathological Q-wave (Q-wave/T-wave score) led to a net reclassification improvement of 0.43 (95% CI 0.29-0.57; p<0.001) as compared to PTI alone. PTI following STEMI is independently and incrementally associated with more extensive myocardial damage as visualized by CMR. An electrocardiographic score combining PTI with pathological Q-wave allows for a highly accurate IS estimation post-STEMI. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Microwave effects on isolated chick embryo hearts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Caddemi, A.; Tamburello, C.C.; Zanforlin, L.

    1986-01-01

    This study was designed to examine the effects of microwaves on the electric activity of hearts as a means of elucidating interactive mechanisms of nonionizing radiation with cardiac tissue. Experiments were performed on isolated hearts of 9-12-day-old chick embryos placed in small petri dishes. Oxygenated isotonic Ringer's solution at 37 degrees C permitted heart survival. Samples were irradiated at 2.45 GHz with a power density of 3 mW/cm2. The heart signal was detected with a glass micropipet inserted into the sinoatrial node and examined by means of a Berg-Fourier analyzer. Pulsed microwaves caused the locking of the heartbeat to themore » modulation frequency, whereas continuous wave irradiation might have induced slight bradycardia. Pulsed fields induced stimulation or regularization of the heartbeat in arrhythmia, fibrillation, or arrest of the heart.« less

  10. New Features of Electrocardiogram in a Case Report of Arrhythmogenic Right Ventricular Cardiomyopathy: A Care-Compliant Article.

    PubMed

    Pei, Haifeng; Yu, Qiujun; Su, Xiaohua; Wang, Zhen; Zhao, Heng; Yang, Dachun; Yang, Yongjian; Li, De

    2016-04-01

    Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a crucial health problem. With sudden death often being the first presentation, early diagnosis for ARVC is essential. Up to date, electrocardiogram (ECG) is a widely used diagnostic method without invasive harms. To diagnose and treat ARVC as well as possible, we should clearly elucidate its pathophysiological alterations. A 66-year-old farmer presented to the Emergency Department with continuous palpitation, chest tightness, profuse sweating, and nausea with no obvious predisposing causes. An ECG indicated ventricular tachycardia (VT). The patient experienced a sudden drop in blood pressure and acute confusion. After an immediate electrical conversion, his consciousness was gradually restored, and symptoms relieved. The patient was then transferred to the Department of Cardiology to receive ECG, echocardiography, coronary angiogram, biochemical assays, endocardiac tracing, and radiofrequency ablation. In the end, he was diagnosed with ARVC, evidenced by bilateral ventricle dilation and epsilon waves in leads V1-V3. Appropriate therapies were provided for this patient including pharmacological intervention and radiofrequency ablation. Although the diagnosis of ARVC is not difficult, this patient's ECG manifested several interesting features and should be further investigated: T wave inversions were found extensively in the anterior and inferior leads, revealing the involvement of bilateral ventricles; VTs with different morphologies and cycle lengths were found, and some VTs manifested the feature of irregularly irregular rhythm, reminding us to carefully differentiate some special VTs from atrial fibrillation (AF); and epsilon waves gradually appeared in leads V1-V3 and avR since the onset of ARVC. Most importantly, the epsilon waves behind QRS complex appeared in both sinus rhythm and ventricular premature beats/VT originating from cardiac apex, whereas the epsilon waves prior to QRS complex occurred in VT originating from right ventricular outflow tract (RVOT). The features of T wave inversion and epsilon wave in ECGs and the appearance of VTs with different morphologies can reflect the progression of ARVC. The position relationship between epsilon wave and QRS complex in VT depends on ventricular activation sequence, that is, the localization of epsilon wave depends on where VT is originating from.

  11. Estimated aortic stiffness is independently associated with cardiac baroreflex sensitivity in humans: role of ageing and habitual endurance exercise.

    PubMed

    Pierce, G L; Harris, S A; Seals, D R; Casey, D P; Barlow, P B; Stauss, H M

    2016-09-01

    We hypothesised that differences in cardiac baroreflex sensitivity (BRS) would be independently associated with aortic stiffness and augmentation index (AI), clinical biomarkers of cardiovascular disease risk, among young sedentary and middle-aged/older sedentary and endurance-trained adults. A total of 36 healthy middle-aged/older (age 55-76 years, n=22 sedentary and n=14 endurance-trained) and 5 young sedentary (age 18-31 years) adults were included in a cross-sectional study. A subset of the middle-aged/older sedentary adults (n=12) completed an 8-week-aerobic exercise intervention. Invasive brachial artery blood pressure waveforms were used to compute spontaneous cardiac BRS (via sequence technique), estimated aortic pulse wave velocity (PWV) and AI (AI, via brachial-aortic transfer function and wave separation analysis). In the cross-sectional study, cardiac BRS was 71% lower in older compared with young sedentary adults (P<0.05), but only 40% lower in older adults who performed habitual endurance exercise (P=0.03). In a regression model that included age, sex, resting heart rate, mean arterial pressure (MAP), body mass index and maximal exercise oxygen uptake, estimated aortic PWV (β±s.e.=-5.76±2.01, P=0.01) was the strongest predictor of BRS (model R(2)=0.59, P<0.001). The 8-week-exercise intervention improved BRS by 38% (P=0.04) and this change in BRS was associated with improved aortic PWV (r=-0.65, P=0.044, adjusted for changes in MAP). Age- and endurance-exercise-related differences in cardiac BRS are independently associated with corresponding alterations in aortic PWV among healthy adults, consistent with a mechanistic link between variations in the sensitivity of the baroreflex and aortic stiffness with age and exercise.

  12. Estimated Aortic Stiffness is Independently Associated with Cardiac Baroreflex Sensitivity in Humans: Role of Aging and Habitual Endurance Exercise

    PubMed Central

    Pierce, Gary L.; Harris, Stephen A.; Seals, Douglas R.; Casey, Darren P.; Barlow, Patrick B.; Stauss, Harald M.

    2016-01-01

    We hypothesized that differences in cardiac baroreflex sensitivity (BRS) would be independently associated with aortic stiffness and augmentation index (AI), clinical biomarkers of cardiovascular disease (CVD) risk, among young sedentary and middle-aged/older sedentary and endurance-trained adults. A total of 36 healthy middle-aged/older (age 55-76 years, n=22 sedentary; n=14 endurance-trained) and 5 young sedentary (age 18-31 years) adults were included in a cross-sectional study. A subset of the middle-aged/older sedentary adults (n=12) completed an 8-week aerobic exercise intervention. Invasive brachial artery blood pressure waveforms were used to compute spontaneous cardiac BRS (via sequence technique) and estimated aortic pulse wave velocity (PWV) and AI (AI, via brachial-aortic transfer function and wave separation analysis). In the cross-sectional study, cardiac BRS was 71% lower in older compared with young sedentary adults (P<0.05), but only 40% lower in older adults who performed habitual endurance exercise (P=0.03). In a regression model that included age, sex, resting heart rate, mean arterial pressure (MAP), body mass index and maximal exercise oxygen uptake, estimated aortic PWV (β±SE = −5.76 ± 2.01, P=0.01) was the strongest predictor of BRS (Model R2=0.59, P<0.001). The 8 week exercise intervention improved BRS by 38% (P=0.04) and this change in BRS was associated with improved aortic PWV (r=−0.65, P=0.044, adjusted for changes in MAP). Age- and endurance exercise-related differences in cardiac BRS are independently associated with corresponding alterations in aortic PWV among healthy adults, consistent with a mechanistic link between variations in the sensitivity of the baroreflex and aortic stiffness with age and exercise. PMID:26911535

  13. Hysteresis effect implicates calcium cycling as a mechanism of repolarization alternans.

    PubMed

    Walker, Mariah L; Wan, Xiaoping; Kirsch, Glenn E; Rosenbaum, David S

    2003-11-25

    T-wave alternans is due to alternation of membrane repolarization at the cellular level and is a risk factor for sudden cardiac death. Recently, a hysteresis effect has been reported in patients whereby T-wave alternans, once induced by rapid heart rate, persists even when heart rate is subsequently slowed. We hypothesized that alternans hysteresis is an intrinsic property of cardiac myocytes, directly related to an underlying mechanism for repolarization alternans that involves intracellular calcium cycling. Stepwise pacing was used to induce alternans in Langendorff-perfused guinea pig hearts from which optical action potentials were recorded simultaneously at 256 ventricular sites with voltage-sensitive dyes and in whole-cell patch-clamped cardiac myocytes treated with or without BAPTA-AM (1,2-bis[2-aminophenoxy]ethane-N,N,N',N'-tetraacetic acid tetrakis [acetoxymethyl ester]). Alternans hysteresis was observed in every isolated heart: threshold heart rate for alternans was 280+/-12 bpm, but during subsequent deceleration of pacing, alternans persisted to significantly slower heart rates (238+/-5 bpm, P<0.05). Optical mapping showed that this effect also applied to the threshold for spatially discordant alternans (313+/-2.2 bpm during acceleration versus 250+/-6.6 bpm during deceleration, P<0.05). Alternans hysteresis was also observed in isolated cardiac myocytes. Moreover, calcium chelation by BAPTA-AM raised the threshold for alternans and inhibited hysteresis in a dose-dependent manner with no effect on baseline action potential duration. Alternans hysteresis is an intrinsic property of cardiac myocytes that can lead to persistence of arrhythmogenic discordant alternans even after heart rate is slowed. These results also support an important underlying role of calcium cycling in the mechanism of alternans.

  14. Cardiac cycle-synchronized electrical muscle stimulator for lower limb training with the potential to reduce the heart's pumping workload

    PubMed Central

    Matsuse, Hiroo; Akimoto, Ryuji; Kamiya, Shiro; Moritani, Toshio; Sasaki, Motoki; Ishizaki, Yuta; Ohtsuka, Masanori; Nakayoshi, Takaharu; Ueno, Takafumi; Shiba, Naoto; Fukumoto, Yoshihiro

    2017-01-01

    Background The lower limb muscle may play an important role in decreasing the heart’s pumping workload. Aging and inactivity cause atrophy and weakness of the muscle, leading to a loss of the heart-assisting role. An electrical lower limb muscle stimulator can prevent atrophy and weakness more effectively than conventional resistance training; however, it has been reported to increase the heart’s pumping workload in some situations. Therefore, more effective tools should be developed. Methods We newly developed a cardiac cycle-synchronized electrical lower limb muscle stimulator by combining a commercially available electrocardiogram monitor and belt electrode skeletal muscle electrical stimulator, making it possible to achieve strong and wide but not painful muscle contractions. Then, we tested the stimulator in 11 healthy volunteers to determine whether the special equipment enabled lower limb muscle training without harming the hemodynamics using plethysmography and a percutaneous cardiac output analyzer. Results In 9 of 11 subjects, the stimulator generated diastolic augmentation waves on the dicrotic notches and end-diastolic pressure reduction waves on the plethysmogram waveforms of the brachial artery, showing analogous waveforms in the intra-aortic balloon pumping heart-assisting therapy. The heart rate, stroke volume, and cardiac output significantly increased during the stimulation. There was no change in the systolic or diastolic blood pressure during the stimulation. Conclusion Cardiac cycle-synchronized electrical muscle stimulation for the lower limbs may enable muscle training without harmfully influencing the hemodynamics and with a potential to reduce the heart’s pumping workload, suggesting a promising tool for effectively treating both locomotor and cardiovascular disorders. PMID:29117189

  15. A Public-Private Consortium Advances Cardiac Safety Evaluation: Achievements of the HESI Cardiac Safety Technical Committee

    EPA Science Inventory

    The evaluation of cardiovascular side-effects is a critical element in the development of all new drugs and chemicals. Cardiac safety issues have been and continue to be a major cause of attrition and withdrawal due to Adverse Drug Reactions (ADRs) in pharmaceutical drug developm...

  16. Metal ring on 4th or 5th finger markedly increases both cardiac troponin I at left ventricle and cancer-related parameters such as oncogen C-fosAb2 & integrin α₅β₁[corrected] by 4-12 times. Thus these metal rings appear to promote both heart problems & cancer.

    PubMed

    Omura, Yoshiaki; Hines, Howard; Jones, Marilyn; O'Young, Brian; Duvvi, Harsha; Lu, Dominic P; Pallos, Andrew; Shimotsuura, Yasuhiro; Ohki, Motomu

    2010-01-01

    We examined patients wearing a metal ring on the left 4th finger with abnormally increased Cardiac Troponin I (which is known to increase in the presence of myocardial injury or left ventricular hypertrophy) of 5-14ng BDORT units (depending on the ring and individual) at left ventricle compared with normal value of 1ng BDORT units or less. Although shape of the ECG does not change significantly regardless of whether metal rings are on or not, when rings are on, the Bi-Digital O-Ring Test evaluation of trace of ECG revealed "Vulnerable Period of Rising Part of T-wave" of ECG waves (which correspond to the left ventricle and AV node) become abnormal with increased Cardiac Troponin I. DHEA in various parts of the body reduced significantly and maximum decrease in DHEA was found when metal ring was on the left 4th and 5th fingers. Telomere reduced with each of the 5 fingers, but the 2nd, 4th, and 5th fingers produced the maximum reduction of telomere. When metal ring was inserted onto the left 1st finger and left 2nd finger, Cardiac Troponin I did not change significantly. Additional abnormality was found when patients with cancer wore metal ring(s); namely both Cardiac Troponin I and cancer parameters, such as Integrin α₅β₁[corrected] and Oncogen C-fos Ab2, increase anywhere between 4-12 times. However, when the ring was cut, creating a 1mm or longer empty space, no increase in cancer markers and Cardiac Troponin I were observed. Similar findings were found with metal bracelets.

  17. Role of imaging in evaluation of sudden cardiac death risk in hypertrophic cardiomyopathy.

    PubMed

    Geske, Jeffrey B; Ommen, Steve R

    2015-09-01

    Hypertrophic cardiomyopathy (HCM) is the most common heritable cardiomyopathy and is associated with sudden cardiac death (SCD) - an uncommon but devastating clinical outcome. This review is designed to assess the role of imaging in established risk factor assessment and its role in emerging SCD risk stratification. Recent publications have highlighted the crucial role of imaging in HCM SCD risk stratification. Left ventricular hypertrophy assessment remains the key imaging determinant of risk. Data continue to emerge on the role of systolic dysfunction, apical aneurysms, left atrial enlargement and left ventricular outflow tract obstruction as markers of risk. Quantitative assessment of delayed myocardial enhancement and T1 mapping on cardiac MRI continue to evolve. Recent multicenter trials have allowed multivariate SCD risk assessment in large HCM cohorts. Given aggregate risk with presence of multiple risk factors, a single parameter should not be used in isolation to determine implantable cardiac defibrillator candidacy. Use of all available imaging data, including cardiac magnetic resonance tissue characterization, allows a comprehensive approach to SCD stratification and implantable cardiac defibrillator decision-making.

  18. Determination of wave speed and wave separation in the arteries.

    PubMed

    Khir, A W; O'Brien, A; Gibbs, J S; Parker, K H

    2001-09-01

    Considering waves in the arteries as infinitesimal wave fronts rather than sinusoidal wavetrains, the change in pressure across the wave front, dP, is related to the change in velocity, dU, that it induces by the "water hammer" equation, dP=+/-rhocdU, where rho is the density of blood and c is the local wave speed. When only unidirectional waves are present, this relationship corresponds to a straight line when P is plotted against U with slope rhoc. When both forward and backward waves are present, the PU-loop is no longer linear. Measurements in latex tubes and systemic and pulmonary arteries exhibit a linear range during early systole and this provides a way of determining the local wave speed from the slope of the linear portion of the loop. Once the wave speed is known, it is also possible to separate the measured P and U into their forward and backward components. In cases where reflected waves are prominent, this separation of waves can help clarify the pattern of waves in the arteries throughout the cardiac cycle.

  19. Transmural Ultrasound-based Visualization of Patterns of Action Potential Wave Propagation in Cardiac Tissue

    PubMed Central

    Luther, Stefan; Singh, Rupinder; Gilmour, Robert F.

    2010-01-01

    The pattern of action potential propagation during various tachyarrhythmias is strongly suspected to be composed of multiple re-entrant waves, but has never been imaged in detail deep within myocardial tissue. An understanding of the nature and dynamics of these waves is important in the development of appropriate electrical or pharmacological treatments for these pathological conditions. We propose a new imaging modality that uses ultrasound to visualize the patterns of propagation of these waves through the mechanical deformations they induce. The new method would have the distinct advantage of being able to visualize these waves deep within cardiac tissue. In this article, we describe one step that would be necessary in this imaging process—the conversion of these deformations into the action potential induced active stresses that produced them. We demonstrate that, because the active stress induced by an action potential is, to a good approximation, only nonzero along the local fiber direction, the problem in our case is actually overdetermined, allowing us to obtain a complete solution. Use of two- rather than three-dimensional displacement data, noise in these displacements, and/or errors in the measurements of the fiber orientations all produce substantial but acceptable errors in the solution. We conclude that the reconstruction of action potential-induced active stress from the deformation it causes appears possible, and that, therefore, the path is open to the development of the new imaging modality. PMID:20499183

  20. [Assessment of professional practices in treating cardiac arrest].

    PubMed

    Mazon, Clara; Kerrou, Yamina

    2017-12-01

    An assessment of professional practices was carried out in 2013-2014 with the aim of improving the treatment of cardiac arrest in hospitals. Two methods were used: an assessment by questionnaire to evaluate theoretical knowledge and a practical assessment of external cardiac massage. The results highlight the need for greater knowledge. The use of cardiac massage must be included in continuing professional development. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  1. 21 CFR 862.1163 - Cardiac allograft gene expression profiling test system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862.1163 Cardiac allograft gene expression profiling test system. (a...

  2. 21 CFR 862.1163 - Cardiac allograft gene expression profiling test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862.1163 Cardiac allograft gene expression profiling test system. (a...

  3. 21 CFR 862.1163 - Cardiac allograft gene expression profiling test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862.1163 Cardiac allograft gene expression profiling test system. (a...

  4. 21 CFR 862.1163 - Cardiac allograft gene expression profiling test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862.1163 Cardiac allograft gene expression profiling test system. (a...

  5. Doxorubicin: Comparison between 3-h continuous and bolus intravenous administration paradigms on cardio-renal axis, mitochondrial sphingolipids and pathology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kamendi, Harriet, E-mail: harriet_kamendi@kandih.com; Zhou, Ying, E-mail: yingzhou526@gmail.com; Crosby, Meredith, E-mail: Meredith.crosby@astrazeneca.com

    Doxorubicin (DOX) is a potent and effective broad-spectrum anthracycline antitumor agent, but its clinical usefulness is restricted by cardiotoxicity. This study compared pharmacokinetic, functional, structural and biochemical effects of single dose DOX bolus or 3-h continuous iv infusion (3-h iv) in the Han–Wistar rat to characterize possible treatment-related differences in drug safety over a 72 h observation period. Both DOX dosing paradigms significantly altered blood pressure, core body temperature and QA interval (indirect measure of cardiac contractility); however, there was no recovery observed in the bolus iv treatment group. Following the 3-h iv treatment, blood pressures and QA interval normalizedmore » by 36 h then rose above baseline levels over 72 h. Both treatments induced biphasic changes in heart rate with initial increases followed by sustained decreases. Cardiac injury biomarkers in plasma were elevated only in the bolus iv treatment group. Tissue cardiac injury biomarkers, cardiac mitochondrial complexes I, III and V and cardiac mitochondrial sphingolipids were decreased only in the bolus iv treatment group. Results indicate that each DOX dosing paradigm deregulates sinus rhythm. However, slowing the rate of infusion allows for functional compensation of blood pressure and may decrease the likelihood of cardiac myocyte necrosis via a mechanism associated with reduced mitochondrial damage. - Highlights: • Despite damaging cardiomyocytes, continuous iv doxorubicin improves cardiovascular outcomes. • This study supports administration of doxorubicin via slow continuous iv infusion limits acute cardio-toxicity. • This study supports use of metabolomic-derived lipid biomarkers for improved quantification of cardiovascular risk. • This study supports systems-based physiological approach to generate a data that can greatly inform risk assessments.« less

  6. Filament Tension and Phase Locking of Meandering Scroll Waves

    NASA Astrophysics Data System (ADS)

    Dierckx, Hans; Biktasheva, I. V.; Verschelde, H.; Panfilov, A. V.; Biktashev, V. N.

    2017-12-01

    Meandering spiral waves are often observed in excitable media such as the Belousov-Zhabotinsky reaction and cardiac tissue. We derive a theory for drift dynamics of meandering rotors in general reaction-diffusion systems and apply it to two types of external disturbances: an external field and curvature-induced drift in three dimensions. We find two distinct regimes: with small filament curvature, meandering scroll waves exhibit filament tension, whose sign determines the stability and drift direction. In the regimes of strong external fields or meandering motion close to resonance, however, phase locking of the meander pattern is predicted and observed.

  7. Filament Tension and Phase Locking of Meandering Scroll Waves.

    PubMed

    Dierckx, Hans; Biktasheva, I V; Verschelde, H; Panfilov, A V; Biktashev, V N

    2017-12-22

    Meandering spiral waves are often observed in excitable media such as the Belousov-Zhabotinsky reaction and cardiac tissue. We derive a theory for drift dynamics of meandering rotors in general reaction-diffusion systems and apply it to two types of external disturbances: an external field and curvature-induced drift in three dimensions. We find two distinct regimes: with small filament curvature, meandering scroll waves exhibit filament tension, whose sign determines the stability and drift direction. In the regimes of strong external fields or meandering motion close to resonance, however, phase locking of the meander pattern is predicted and observed.

  8. Liberation of a pinned spiral wave by a rotating electric pulse

    NASA Astrophysics Data System (ADS)

    Chen, Jiang-Xing; Peng, Liang; Ma, Jun; Ying, He-Ping

    2014-08-01

    Spiral waves may be pinned to anatomical heterogeneities in the cardiac tissue, which leads to monomorphic ventricular tachycardia. Wave emission from heterogeneities (WEH) induced by electric pulses in one direction (EP) is a promising method for liberating such waves by using heterogeneities as internal virtual pacing sites. Here, based on the WEH effect, a new mechanism of liberation by means of a rotating electric pulse (REP) is proposed in a generic model of excitable media. Compared with the EP, the REP has the advantage of opening wider time window to liberate pinned spiral. The influences of rotating direction and frequency of the REP, and the radius of the obstacles on this new mechanism are studied. We believe this strategy may improve manipulations with pinned spiral waves in heart experiments.

  9. Non-invasive measurement of the haemodynamic effects of inhaled salbutamol, intravenous L-arginine and sublingual nitroglycerin

    PubMed Central

    Tahvanainen, Anna; Leskinen, Miia; Koskela, Jenni; Ilveskoski, Erkki; Alanko, Juha; Kähönen, Mika; Kööbi, Tiit; Lehtimäki, Lauri; Moilanen, Eeva; Mustonen, Jukka; Pörsti, Ilkka

    2009-01-01

    AIMS To examine the effects of salbutamol and L-arginine, two compounds acting largely on the endothelium, and the endothelium-independent agent nitroglycerin on blood pressure, arterial compliance, cardiac function and vascular resistance. METHODS Continuous radial pulse wave analysis, whole-body impedance cardiography, and plethysmographic blood pressure from fingers in the supine position and during head-up tilt were recorded in nine healthy subjects. Data were captured before and after L-arginine (10 mg mg−1 min−1) or saline infusion, salbutamol (400 µg) or placebo inhalation, and sublingual nitroglycerin (0.25 mg) or placebo resoriblet. RESULTS The results of all measurements were comparable before drug administration. The effects of inhaled salbutamol were apparent in the supine position: systemic vascular resistance (−9.2 ± 2.6%) and augmentation index (−4.0 ± 1.5%) decreased, and heart rate (8.6 ± 2.5%) and cardiac output (8.8 ± 3.1%) increased. L-arginine had no clear effects on supine haemodynamics, but during head-up tilt blood pressure was moderately decreased and reduction in aortic reflection time prevented, indicating improved large arterial compliance. Nitroglycerin reduced supine vascular resistance (−6.7 ± 1.8%) and augmentation index (−7.4 ± 1.6%), and increased cardiac output (+9.2 ± 2.7%). During head-up tilt, nitroglycerin increased cardiac output (+10.6 ± 5.6%) and heart rate (+40 ± 7.5%), decreased vascular resistance (−7.8 ± 5.8%) and augmentation index (−18.7 ± 3.2%), and prevented the decrease in aortic reflection time. CONCLUSIONS Inhaled salbutamol predominantly changed supine haemodynamics, whereas the moderate effects of L-arginine were observed during the head-up tilt. In contrast, small doses of nitroglycerin induced major changes in haemodynamics both supine and during the head-up tilt. Altogether, these results emphasize the importance of haemodynamic measurements in both the supine and upright positions. PMID:19660000

  10. Quantitative shear wave imaging optical coherence tomography for noncontact mechanical characterization of myocardium

    NASA Astrophysics Data System (ADS)

    Wang, Shang; Lopez, Andrew L.; Morikawa, Yuka; Tao, Ge; Li, Jiasong; Larina, Irina V.; Martin, James F.; Larin, Kirill V.

    2015-03-01

    Optical coherence elastography (OCE) is an emerging low-coherence imaging technique that provides noninvasive assessment of tissue biomechanics with high spatial resolution. Among various OCE methods, the capability of quantitative measurement of tissue elasticity is of great importance for tissue characterization and pathology detection across different samples. Here we report a quantitative OCE technique, termed quantitative shear wave imaging optical coherence tomography (Q-SWI-OCT), which enables noncontact measurement of tissue Young's modulus based on the ultra-fast imaging of the shear wave propagation inside the sample. A focused air-puff device is used to interrogate the tissue with a low-pressure short-duration air stream that stimulates a localized displacement with the scale at micron level. The propagation of this tissue deformation in the form of shear wave is captured by a phase-sensitive OCT system running with the scan of the M-mode imaging over the path of the wave propagation. The temporal characteristics of the shear wave is quantified based on the cross-correlation of the tissue deformation profiles at all the measurement locations, and linear regression is utilized to fit the data plotted in the domain of time delay versus wave propagation distance. The wave group velocity is thus calculated, which results in the quantitative measurement of the Young's modulus. As the feasibility demonstration, experiments are performed on tissuemimicking phantoms with different agar concentrations and the quantified elasticity values with Q-SWI-OCT agree well with the uniaxial compression tests. For functional characterization of myocardium with this OCE technique, we perform our pilot experiments on ex vivo mouse cardiac muscle tissues with two studies, including 1) elasticity difference of cardiac muscle under relaxation and contract conditions and 2) mechanical heterogeneity of the heart introduced by the muscle fiber orientation. Our results suggest the potential of using Q-SWI-OCT as an essential tool for nondestructive biomechanical evaluation of myocardium.

  11. Electrical stimulation of cardiac adipose tissue-derived progenitor cells modulates cell phenotype and genetic machinery.

    PubMed

    Llucià-Valldeperas, A; Sanchez, B; Soler-Botija, C; Gálvez-Montón, C; Prat-Vidal, C; Roura, S; Rosell-Ferrer, J; Bragos, R; Bayes-Genis, A

    2015-11-01

    A major challenge of cardiac tissue engineering is directing cells to establish the physiological structure and function of the myocardium being replaced. Our aim was to examine the effect of electrical stimulation on the cardiodifferentiation potential of cardiac adipose tissue-derived progenitor cells (cardiac ATDPCs). Three different electrical stimulation protocols were tested; the selected protocol consisted of 2 ms monophasic square-wave pulses of 50 mV/cm at 1 Hz over 14 days. Cardiac and subcutaneous ATDPCs were grown on biocompatible patterned surfaces. Cardiomyogenic differentiation was examined by real-time PCR and immunocytofluorescence. In cardiac ATDPCs, MEF2A and GATA-4 were significantly upregulated at day 14 after stimulation, while subcutaneous ATDPCs only exhibited increased Cx43 expression. In response to electrical stimulation, cardiac ATDPCs elongated, and both cardiac and subcutaneous ATDPCs became aligned following the linear surface pattern of the construct. Cardiac ATDPC length increased by 11.3%, while subcutaneous ATDPC length diminished by 11.2% (p = 0.013 and p = 0.030 vs unstimulated controls, respectively). Compared to controls, electrostimulated cells became aligned better to the patterned surfaces when the pattern was perpendicular to the electric field (89.71 ± 28.47º for cardiac ATDPCs and 92.15 ± 15.21º for subcutaneous ATDPCs). Electrical stimulation of cardiac ATDPCs caused changes in cell phenotype and genetic machinery, making them more suitable for cardiac regeneration approaches. Thus, it seems advisable to use electrical cell training before delivery as a cell suspension or within engineered tissue. Copyright © 2013 John Wiley & Sons, Ltd.

  12. Ventricular-arterial coupling in a rat model of reduced arterial compliance provoked by hypervitaminosis D and nicotine.

    PubMed

    Jegger, David; da Silva, Rafaela; Jeanrenaud, Xavier; Nasratullah, Mohammad; Tevaearai, Hendrik; von Segesser, Ludwig K; Segers, Patrick; Gaillard, Virginie; Atkinson, Jeffrey; Lartaud, Isabelle; Stergiopulo, Nikolaos

    2006-10-01

    The vitamin D(3) and nicotine (VDN) model is one of isolated systolic hypertension (ISH) in which arterial calcification raises arterial stiffness and vascular impedance. The effects of VDN treatment on arterial and cardiac hemodynamics have been investigated; however, a complete analysis of ventricular-arterial interaction is lacking. Wistar rats were treated with VDN (VDN group, n = 9), and a control group (n = 10) was included without the VDN. At week 8, invasive indexes of cardiac function were obtained using a conductance catheter. Simultaneously, aortic pressure and flow were measured to derive vascular impedance and characterize ventricular-vascular interaction. VDN caused significant increases in systolic (138 +/- 6 vs. 116 +/- 13 mmHg, P < 0.01) and pulse (42 +/- 10 vs. 26 +/- 4 mmHg, P < 0.01) pressures with respect to control. Total arterial compliance decreased (0.12 +/- 0.08 vs. 0.21 +/- 0.04 ml/mmHg in control, P < 0.05), and pulse wave velocity increased significantly (8.8 +/- 2.5 vs. 5.1 +/- 2.0 m/s in control, P < 0.05). The arterial elastance and end-systolic elastance rose significantly in the VDN group (P < 0.05). Wave reflection was augmented in the VDN group, as reflected by the increase in the wave reflection coefficient (0.63 +/- 0.06 vs. 0.52 +/- 0.05 in control, P < 0.05) and the amplitude of the reflected pressure wave (13.3 +/- 3.1 vs. 8.4 +/- 1.0 mmHg in control, P < 0.05). We studied ventricular-arterial coupling in a VDN-induced rat model of reduced arterial compliance. The VDN treatment led to development of ISH and provoked alterations in cardiac function, arterial impedance, arterial function, and ventricular-arterial interaction, which in many aspects are similar to effects of an aged and stiffened arterial tree.

  13. Physical activity measured by accelerometry and its associations with cardiac structure and vascular function in young and middle-aged adults.

    PubMed

    Andersson, Charlotte; Lyass, Asya; Larson, Martin G; Spartano, Nicole L; Vita, Joseph A; Benjamin, Emelia J; Murabito, Joanne M; Esliger, Dale W; Blease, Susan J; Hamburg, Naomi M; Mitchell, Gary F; Vasan, Ramachandran S

    2015-03-19

    Physical activity is associated with several health benefits, including lower cardiovascular disease risk. The independent influence of physical activity on cardiac and vascular function in the community, however, has been sparsely investigated. We related objective measures of moderate- to vigorous-intensity physical activity (MVPA, assessed by accelerometry) to cardiac and vascular indices in 2376 participants of the Framingham Heart Study third generation cohort (54% women, mean age 47 years). Using multivariable regression models, we related MVPA to the following echocardiographic and vascular measures: left ventricular mass, left atrial and aortic root sizes, carotid-femoral pulse wave velocity, augmentation index, and forward pressure wave. Men and women engaged in MVPA 29.9±21.4 and 25.5±19.4 min/day, respectively. Higher values of MVPA (per 10-minute increment) were associated with lower carotid-femoral pulse wave velocity (estimate -0.53 ms/m; P=0.006) and lower forward pressure wave (estimate -0.23 mm Hg; P=0.03) but were not associated with augmentation index (estimate 0.13%; P=0.25). MVPA was associated positively with log(e) left ventricular mass (estimate 0.006 log(e) [g/m(2)]; P=0.0003), left ventricular wall thickness (estimate 0.07 mm; P=0.0001), and left atrial dimension (estimate 0.10 mm; P=0.01). MVPA also tended to be positively associated with aortic root dimension (estimate 0.05 mm; P=0.052). Associations of MVPA with cardiovascular measures were similar, in general, for bouts lasting <10 versus ≥10 minutes. In our community-based sample, greater physical activity was associated with lower vascular stiffness but with higher echocardiographic left ventricular mass and left atrial size. These findings suggest complex relations of usual levels of physical activity and cardiovascular remodeling. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  14. Changes in cardiac contractility during graded exercise are greater in subjects with smaller body mass index, and greater in men than women: analyses using wave intensity and force-frequency relations.

    PubMed

    Tanaka, Midori; Sugawara, Motoaki; Niki, Kiyomi; Ogasawara, Yasuo

    2018-06-15

    Estimation of the contractility of the left ventricle during exercise is an important part of the rehabilitation protocol. It is known that cardiac contractility increases with an increase in heart rate. This phenomenon is called the force-frequency relation (FFR). Using wave intensity, we aimed to evaluate FFR noninvasively during graded exercise. We enrolled 83 healthy subjects. Using ultrasonic diagnostic equipment, we measured wave intensity (WD), which was defined in terms of blood velocity and arterial diameter, in the carotid artery and heart rate (HR) before and during bicycle ergometer exercise. FFRs were constructed by plotting the maximum value of WD (WD 1 ) against HR. We analyzed the variation among FFR responses of individual subjects. WD 1 increased linearly with an increase in HR during exercise. The average slope of the FFR was 1.0 ± 0.5 m/s 3  bpm. The slope of FFR decreased with an increase in body mass index (BMI). The slopes of FFRs were steeper in men than women, although there were no differences in BMI between men and women. The FFR was obtained noninvasively by carotid arterial wave intensity (WD 1 ) and graded exercise. The slope of the FFR decreased with an increase in BMI, and was steeper in men than women.

  15. T-wave morphology can distinguish healthy controls from LQTS patients.

    PubMed

    Immanuel, S A; Sadrieh, A; Baumert, M; Couderc, J P; Zareba, W; Hill, A P; Vandenberg, J I

    2016-09-01

    Long QT syndrome (LQTS) is an inherited disorder associated with prolongation of the QT/QTc interval on the surface electrocardiogram (ECG) and a markedly increased risk of sudden cardiac death due to cardiac arrhythmias. Up to 25% of genotype-positive LQTS patients have QT/QTc intervals in the normal range. These patients are, however, still at increased risk of life-threatening events compared to their genotype-negative siblings. Previous studies have shown that analysis of T-wave morphology may enhance discrimination between control and LQTS patients. In this study we tested the hypothesis that automated analysis of T-wave morphology from Holter ECG recordings could distinguish between control and LQTS patients with QTc values in the range 400-450 ms. Holter ECGs were obtained from the Telemetric and Holter ECG Warehouse (THEW) database. Frequency binned averaged ECG waveforms were obtained and extracted T-waves were fitted with a combination of 3 sigmoid functions (upslope, downslope and switch) or two 9th order polynomial functions (upslope and downslope). Neural network classifiers, based on parameters obtained from the sigmoid or polynomial fits to the 1 Hz and 1.3 Hz ECG waveforms, were able to achieve up to 92% discrimination between control and LQTS patients and 88% discrimination between LQTS1 and LQTS2 patients. When we analysed a subgroup of subjects with normal QT intervals (400-450 ms, 67 controls and 61 LQTS), T-wave morphology based parameters enabled 90% discrimination between control and LQTS patients, compared to only 71% when the groups were classified based on QTc alone. In summary, our Holter ECG analysis algorithms demonstrate the feasibility of using automated analysis of T-wave morphology to distinguish LQTS patients, even those with normal QTc, from healthy controls.

  16. Electrocardiography based prediction of hypertrophy pattern and fibrosis amount in hypertrophic cardiomyopathy: comparative study with cardiac magnetic resonance imaging.

    PubMed

    Park, Chul Hwan; Chung, Hyemoon; Kim, Yoonjung; Kim, Jong-Youn; Min, Pil-Ki; Lee, Kyung-A; Yoon, Young Won; Kim, Tae Hoon; Lee, Byoung Kwon; Hong, Bum-Kee; Rim, Se-Joong; Kwon, Hyuck Moon; Choi, Eui-Young

    2018-05-04

    Although, cardiac magnetic resonance imaging (CMR) is a gold standard for risk stratification of hypertrophic cardiomyopathy (HCM), is limited in some situations. We sought to evaluate the predictive power of quantitative electrocardiography in assessing hypertrophy pattern and fibrosis in HCM. Eighty-eight patients with HCM were studied. Voltage of R-S-T waves, number of fragmented QRS (fQRS) complexes, and T wave morphology were measured by 12-lead electrocardiography. Sixteen segmental thickness, late gadolinium enhancement (LGE), native T1, extracellular volume fraction (ECV), and T2, left ventricular (LV) mass and %LGE were measured by CMR. Patterns of LV hypertrophy were classified as pure apical, mixed, or asymmetrical septal hypertrophy. Positive and negative predictive values of biphasic T wave for pure apical type were 70.4 and 63.9%, and the predictive values of precordial negative T wave sums [Formula: see text] 12.5 mm were 69.2 and 79.6%. Precordial S waves, especially Cornell voltage index, were significantly correlated to LV mass index and maximal thickness (p [Formula: see text]0.001). The number of fQRS leads was significantly correlated to %LGE, average ECV, and T2 (all p [Formula: see text]0.001). More than one lead with fQRS could predict [Formula: see text]5% of LGE mass with 58% sensitivity and 63% specificity (p = 0.049, area under the curve = 0.627). However, degree of correlation between maximal thickness and precordial S was poor in cases with fQRS more two leads. T wave morphology and precordial S helps discriminate hypertrophy pattern and maximal hypertrophy, however, in cases with more than two leads of concomitant fQRS, CMR defines fibrosis amount and hypertrophy more accurately.

  17. Increased Energy Demand during Adrenergic Receptor Stimulation Contributes to Ca(2+) Wave Generation.

    PubMed

    Bovo, Elisa; Mazurek, Stefan R; de Tombe, Pieter P; Zima, Aleksey V

    2015-10-20

    While β-adrenergic receptor (β-AR) stimulation ensures adequate cardiac output during stress, it can also trigger life-threatening cardiac arrhythmias. We have previously shown that proarrhythmic Ca(2+) waves during β-AR stimulation temporally coincide with augmentation of reactive oxygen species (ROS) production. In this study, we tested the hypothesis that increased energy demand during β-AR stimulation plays an important role in mitochondrial ROS production and Ca(2+)-wave generation in rabbit ventricular myocytes. We found that β-AR stimulation with isoproterenol (0.1 μM) decreased the mitochondrial redox potential and the ratio of reduced to oxidated glutathione. As a result, β-AR stimulation increased mitochondrial ROS production. These metabolic changes induced by isoproterenol were associated with increased sarcoplasmic reticulum (SR) Ca(2+) leak and frequent diastolic Ca(2+) waves. Inhibition of cell contraction with the myosin ATPase inhibitor blebbistatin attenuated oxidative stress as well as spontaneous SR Ca(2+) release events during β-AR stimulation. Furthermore, we found that oxidative stress induced by β-AR stimulation caused the formation of disulfide bonds between two ryanodine receptor (RyR) subunits, referred to as intersubunit cross-linking. Preventing RyR cross-linking with N-ethylmaleimide decreased the propensity of Ca(2+) waves induced by β-AR stimulation. These data suggest that increased energy demand during sustained β-AR stimulation weakens mitochondrial antioxidant defense, causing ROS release into the cytosol. By inducing RyR intersubunit cross-linking, ROS can increase SR Ca(2+) leak to the critical level that can trigger proarrhythmic Ca(2+) waves. Copyright © 2015 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  18. Toward a More Efficient Implementation of Antifibrillation Pacing

    PubMed Central

    Wilson, Dan; Moehlis, Jeff

    2016-01-01

    We devise a methodology to determine an optimal pattern of inputs to synchronize firing patterns of cardiac cells which only requires the ability to measure action potential durations in individual cells. In numerical bidomain simulations, the resulting synchronizing inputs are shown to terminate spiral waves with a higher probability than comparable inputs that do not synchronize the cells as strongly. These results suggest that designing stimuli which promote synchronization in cardiac tissue could improve the success rate of defibrillation, and point towards novel strategies for optimizing antifibrillation pacing. PMID:27391010

  19. Hypertensive crisis-induced electrocardiographic changes: a case series

    PubMed Central

    2009-01-01

    Introduction Myocardial injury is one of the most notorious complications of a hypertensive crisis. Key electrocardiograph signs used to detect cardiac injury such as ST segment changes and cardiac arrhythmias usually indicate acute ongoing end-organ damage. Lack of early signs to predict end-organ damage might lead to a delay in the initiation of therapy and selection of the incorrect therapeutic strategy. Case presentation We describe five cases of tall, hyper acute symmetrical T-waves alone or accompanied by other electrocardiograph abnormalities in five healthy participants: three women aged 52, 60 and 62-years and two men aged 49 and 66-years, during a tyramine-monoamine oxidase-inhibitor interaction, phase I clinical trial. T-wave changes appeared early during the course of the hypertensive crisis and were attributed to subendocardial ischemia. The changes were transient and reverted to baseline in parallel with a fall in blood pressure. Conclusion Recognition of tall symmetrical T-waves in early phases of hypertensive crisis heralds commencement of myocardial damage. This calls for prompt medical intervention to avoid an impending irreversible myocardial injury. It is our belief that these findings will add new insight into the management of hypertensive crisis and will open avenues of further investigation. PMID:19918270

  20. Hypertensive crisis-induced electrocardiographic changes: a case series.

    PubMed

    Farha, Khalid Abou; van Vliet, André; van Marle, Sjoerd; Vrijlandt, Patrick; Westenbrink, Daan

    2009-08-20

    Myocardial injury is one of the most notorious complications of a hypertensive crisis. Key electrocardiograph signs used to detect cardiac injury such as ST segment changes and cardiac arrhythmias usually indicate acute ongoing end-organ damage. Lack of early signs to predict end-organ damage might lead to a delay in the initiation of therapy and selection of the incorrect therapeutic strategy. We describe five cases of tall, hyper acute symmetrical T-waves alone or accompanied by other electrocardiograph abnormalities in five healthy participants: three women aged 52, 60 and 62-years and two men aged 49 and 66-years, during a tyramine-monoamine oxidase-inhibitor interaction, phase I clinical trial. T-wave changes appeared early during the course of the hypertensive crisis and were attributed to subendocardial ischemia. The changes were transient and reverted to baseline in parallel with a fall in blood pressure. Recognition of tall symmetrical T-waves in early phases of hypertensive crisis heralds commencement of myocardial damage. This calls for prompt medical intervention to avoid an impending irreversible myocardial injury. It is our belief that these findings will add new insight into the management of hypertensive crisis and will open avenues of further investigation.

  1. Mechanisms of decreased left ventricular preload during continuous positive pressure ventilation in ARDS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dhainaut, J.F.; Devaux, J.Y.; Monsallier, J.F.

    1986-07-01

    Continuous positive pressure ventilation is associated with a reduction in left ventricular preload and cardiac output, but the mechanisms responsible are controversial. The decrease in left ventricular preload may result exclusively from a decreased systemic venous return due to increased pleural pressure, or from an additional effect such as decreased left ventricular compliance. To determine the mechanisms responsible, we studied the changes in cardiac output induced by continuous positive pressure ventilation in eight patients with the adult respiratory distress syndrome. We measured cardiac output by thermodilution, and biventricular ejection fraction by equilibrium gated blood pool scintigraphy. Biventricular end-diastolic volumes weremore » then calculated by dividing stroke volume by ejection fraction. As positive end-expiratory pressure increased from 0 to 20 cm H/sub 2/O, stroke volume and biventricular end-diastolic volumes fell about 25 percent, and biventricular ejection fraction remained unchanged. At 20 cm H/sub 2/O positive end-expiratory pressure, volume expansion for normalizing cardiac output restored biventricular end-diastolic volumes without markedly changing biventricular end-diastolic transmural pressures. The primary cause of the reduction in left ventricular preload with continuous positive pressure ventilation appears to be a fall in venous return and hence in right ventricular stroke volume, without evidence of change in left ventricular diastolic compliance.« less

  2. [Camera-cinematography of the heart (author's transl)].

    PubMed

    Adam, W E; Meyer, G; Bitter, F; Kampmann, H; Bargon, G; Stauch, M

    1975-07-01

    By "camera-cinematography" of the heart, we mean an isotope method which permits detailed observation of cardiac mechanics without the use of a catheter. All that is necessary is an intravenous injection of 10 to 15 mCi 99mTc human serum albumen followed after ten minutes by a five to ten minute period of observation with a scintilation camera. At this time the isotope has become distributed in the blood. Variations in the precordial impulses correspond with intra-cardiac changes of blood volume during a cardiac cycle. Analysis of the R-wave provides adequate information of cyclical volume changes in limited portions of the heart. This is achieved by a monitor with a pseudo-3-dimensional display; contraction and relaxation of the myocardium can be shown for any chosen longitudinal or horizontal diameter of the heart. Our programme allows simultaneous presentation of the movement of any point on the myocardium as a time-activity curve. The method is recommended as an addition to chest radiography, heart screening or cardiac kymography before carrying out cardiac catheterisation.

  3. Vortex ring behavior provides the epigenetic blueprint for the human heart

    PubMed Central

    Arvidsson, Per M.; Kovács, Sándor J.; Töger, Johannes; Borgquist, Rasmus; Heiberg, Einar; Carlsson, Marcus; Arheden, Håkan

    2016-01-01

    The laws of fluid dynamics govern vortex ring formation and precede cardiac development by billions of years, suggesting that diastolic vortex ring formation is instrumental in defining the shape of the heart. Using novel and validated magnetic resonance imaging measurements, we show that the healthy left ventricle moves in tandem with the expanding vortex ring, indicating that cardiac form and function is epigenetically optimized to accommodate vortex ring formation for volume pumping. Healthy hearts demonstrate a strong coupling between vortex and cardiac volumes (R2 = 0.83), but this optimized phenotype is lost in heart failure, suggesting restoration of normal vortex ring dynamics as a new, and possibly important consideration for individualized heart failure treatment. Vortex ring volume was unrelated to early rapid filling (E-wave) velocity in patients and controls. Characteristics of vortex-wall interaction provide unique physiologic and mechanistic information about cardiac diastolic function that may be applied to guide the design and implantation of prosthetic valves, and have potential clinical utility as therapeutic targets for tailored medicine or measures of cardiac health. PMID:26915473

  4. Vortex ring behavior provides the epigenetic blueprint for the human heart.

    PubMed

    Arvidsson, Per M; Kovács, Sándor J; Töger, Johannes; Borgquist, Rasmus; Heiberg, Einar; Carlsson, Marcus; Arheden, Håkan

    2016-02-26

    The laws of fluid dynamics govern vortex ring formation and precede cardiac development by billions of years, suggesting that diastolic vortex ring formation is instrumental in defining the shape of the heart. Using novel and validated magnetic resonance imaging measurements, we show that the healthy left ventricle moves in tandem with the expanding vortex ring, indicating that cardiac form and function is epigenetically optimized to accommodate vortex ring formation for volume pumping. Healthy hearts demonstrate a strong coupling between vortex and cardiac volumes (R(2) = 0.83), but this optimized phenotype is lost in heart failure, suggesting restoration of normal vortex ring dynamics as a new, and possibly important consideration for individualized heart failure treatment. Vortex ring volume was unrelated to early rapid filling (E-wave) velocity in patients and controls. Characteristics of vortex-wall interaction provide unique physiologic and mechanistic information about cardiac diastolic function that may be applied to guide the design and implantation of prosthetic valves, and have potential clinical utility as therapeutic targets for tailored medicine or measures of cardiac health.

  5. Measuring Age-Dependent Myocardial Stiffness across the Cardiac Cycle using MR Elastography: A Reproducibility Study

    PubMed Central

    Wassenaar, Peter A; Eleswarpu, Chethanya N; Schroeder, Samuel A; Mo, Xiaokui; Raterman, Brian D; White, Richard D; Kolipaka, Arunark

    2015-01-01

    Purpose To assess reproducibility in measuring left ventricular (LV) myocardial stiffness in volunteers throughout the cardiac cycle using magnetic resonance elastography (MRE) and to determine its correlation with age. Methods Cardiac MRE (CMRE) was performed on 29 normal volunteers, with ages ranging from 21 to 73 years. For assessing reproducibility of CMRE-derived stiffness measurements, scans were repeated per volunteer. Wave images were acquired throughout the LV myocardium, and were analyzed to obtain mean stiffness during the cardiac cycle. CMRE-derived stiffness values were correlated to age. Results Concordance correlation coefficient revealed good inter-scan agreement with rc of 0.77, with p-value<0.0001. Significantly higher myocardial stiffness was observed during end-systole (ES) compared to end-diastole (ED) across all subjects. Additionally, increased deviation between ES and ED stiffness was observed with increased age. Conclusion CMRE-derived stiffness is reproducible, with myocardial stiffness changing cyclically across the cardiac cycle. Stiffness is significantly higher during ES compared to ED. With age, ES myocardial stiffness increases more than ED, giving rise to an increased deviation between the two. PMID:26010456

  6. Wireless miniature implantable devices and ASICs for monitoring, treatment, and study of glaucoma and cardiac disease

    NASA Astrophysics Data System (ADS)

    Chow, Eric Y.

    Glaucoma affects about 65 million people and is the second leading cause of blindness in the world. Although the condition is irreversible and incurable, early detection is vital to slowing and even stopping the progression of the disease. Our work focuses on the design, fabrication, and assembly of a continuous active glaucoma intraocular pressure (IOP) monitor that provides clinicians with the necessary data to more accurately diagnose and treat patients. Major benefits of an active monitoring device include the potential to develop a closed-loop treatment system and to operate independently for extended periods of time. The fully wireless operation uses gigahertzfrequency electromagnetic wave propagation, which allows for an orientation independent transfer of power and data over reasonable distances. Our system is comprised of a MEMS capacitive sensor, capacitive power storage array, ASIC, and monopole antenna assembled into a biocompatible liquid crystal polymer (LCP) package. We have performed in vivo trials on rabbits, both chronic and acute, to validate system functionality, fully wireless feasibility, and biocompatibility. Heart failure (HF) affects approximately 2% of the adult population in developed countries and 6-10% of people over the age of 65. Continuous monitoring of blood pressure, flow, and chemistry from a minimally invasive device can serve as a diagnostic and early-warning system for cardiac health. We developed a miniaturized system attached to the outer surface of an FDA approved stent, used as both the antenna for wireless telemetry/powering and structural support. The system comprises of a MEMS pressure sensor, ASIC for the sensor interface and wireless capabilities, LCP substrate, and FDA approved stent. In vivo studies on pigs validated functionality and fully wireless operation and demonstrate the feasibility of a stent-based wireless implant for continuous monitoring of blood pressure as well as other parameters including oxygen, flow and turbulence, chemistry, and glucose.

  7. Wearable seismocardiography: towards a beat-by-beat assessment of cardiac mechanics in ambulant subjects.

    PubMed

    Di Rienzo, M; Vaini, E; Castiglioni, P; Merati, G; Meriggi, P; Parati, G; Faini, A; Rizzo, F

    2013-11-01

    Seismocardiogram (SCG) is the measure of the micro-vibrations produced by the heart contraction and blood ejection into the vascular tree. Over time, a large body of evidence has been collected on the ability of SCG to reflect cardiac mechanical events such as opening and closure of mitral and aortic valves, atrial filling and point of maximal aortic blood ejection. We recently developed a smart garment, named MagIC-SCG, that allows the monitoring of SCG, electrocardiogram (ECG) and respiration out of the laboratory setting in ambulant subjects. The present pilot study illustrates the results of two different experiments performed to obtain a first evaluation on whether a dynamical assessment of indexes of cardiac mechanics can be obtained from SCG recordings obtained by MagIC-SCG. In the first experiment, we evaluated the consistency of the estimates of two indexes of cardiac contractility, the pre-ejection period, PEP, and the left ventricular ejection time, LVET. This was done in the lab, by reproducing an experimental protocol well known in literature, so that our measures derived from SCG could have been compared with PEP and LVET reference values obtained by traditional techniques. Six healthy subjects worn MagIC-SCG while assuming two different postures (supine and standing); PEP was estimated as the time interval between the Q wave in ECG and the SCG wave corresponding to the opening of aortic valve; LVET was the time interval between the SCG waves corresponding to the opening and closure of the aortic valve. The shift from supine to standing posture produced a significant increase in PEP and PEP/LVET ratio, a reduction in LVET and a concomitant rise in the LF/HF ratio in the RR interval (RRI) power spectrum. These results are in line with data available in literature thus providing a first support to the validity of our estimates. In the second experiment, we evaluated in one subject the feasibility of the beat-by-beat assessment of LVET during spontaneous behavior. The subject was continuously monitored by the smart garment from 8 am to 8 pm during a workday. From the whole recording, three data segments were selected: while the subject was traveling to work (M1), during work in the office (O) and while traveling back home (M2). LVET was estimated on a beat-by-beat basis from SCG and the RRI influence was removed by regression analysis. The LVET series displayed marked beat-by-beat fluctuations at the respiratory frequency. The amplitude of these fluctuations changed in the three periods and was lower when the LF/HF RRI power ratio was higher, at O, thus suggesting a possible influence of the autonomic nervous system on LVET short-term variability. To the best of our knowledge this case report provides for the first time a representation of the beat-by-beat dynamics of a systolic time interval during daily activity. The statistical characterization of these findings remains to be explored on a larger population. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. [Cardiac Anaesthesia: Anaesthesiological Management].

    PubMed

    Renner, Jochen; Bein, Berthold; Broch, Ole

    2018-05-01

    The anaesthesiological management of patients scheduled for cardiac surgery has been refined distinctively over the last decade due to different reasons. The continuing growth of the elderly patient population and the increasing number of combined cardiac surgery procedures in octogenarians on the one hand are one aspect. The rapid development of minimally invasive cardiac surgery and the enhancements in mechanical, artificial heart assist devices on the other hand can be seen as additional decisive factors. All of these innovations in the field of cardiac surgery implicate further enhancements regarding the anaesthesiological management. This review article addresses the following subareas of cardiac anaesthesia: significance of pharmacological myocardial protection, anaesthetic management during cardiopulmonary bypass, importance of "Enhanced Recovery After Cardiac Surgery"-protocols as well as innovations in the field of minimally invasive cardiac surgery like transcatheter aortic valve implantation. Georg Thieme Verlag KG Stuttgart · New York.

  9. Feedback control for stabilizing chaotic spiral waves during cardiac ventricular fibrillation

    NASA Astrophysics Data System (ADS)

    Uzelac, Ilija; Wikswo, John; Gray, Richard

    2011-03-01

    The cardiac arrhythmias that lead to ventricular fibrillation (VF) arise from electrical spiral waves (SW) rotating within the heart with a characteristic period τ . A single drifting SW can degenerate into a chaotic system of multiple SWs and VF. Hence early SW detection and termination is crucial to prevent VF. Time-delayed feedback control (TDFC) is well known approach for stabilizing unstable periodic orbits embedded in chaotic attractors. We hypothesize that cardiac SWs can be stabilized by TDFC with a time-delay of τ . Implementing this approach will require precise, closed-loop control of the charge delivered to the heart during the defibrillation process. To do this, we have developed a 2 kW arbitrary-waveform voltage-to-current converter (V2CC) with a 1 kHz bandwidth that can deliver up to 5 A at 400 V for 500 ms, and a photodiode system for recording in real time an optical electrocardiogram, OECG(t). The feedback signal driving the V2CC will be the time-difference (OECG(t) - OECG(t-T), where we hypothesize that T is τ , the period of the SW. This may dramatically decrease defibrillation voltages by using a defibrillation waveform customized to the VF event, unlike commercial capacitor defibrillators. Supported in part by NIH R01 HL58241-11 through ARRA 2009.

  10. In vitro assessment of the immunity of implantable cardioverter-defibrillators to magnetic fields of 50/60 Hz.

    PubMed

    Katrib, J; Nadi, M; Kourtiche, D; Magne, I; Schmitt, P; Souques, M; Roth, P

    2013-10-01

    Public concern for the compatibility of electromagnetic (EM) sources with active implantable medical devices (AIMD) has prompted the development of new systems that can perform accurate exposure studies. EM field interference with active cardiac implants (e.g. implantable cardioverter-defibrillators (ICDs)) can be critical. This paper describes a magnetic field (MF) exposure system and the method developed for testing the immunity of ICD to continuous-wave MFs. The MFs were created by Helmholtz coils, housed in a Faraday cage. The coils were able to produce highly uniform MFs up to 4000 µT at 50 Hz and 3900 µT at 60 Hz, within the test space. Four ICDs were tested. No dysfunctions were found in the generated MFs. These results confirm that the tested ICDs were immune to low frequency MFs.

  11. The Role of Transmural Repolarization Gradient in the Inversion of Cardiac Electric Field: Model Study of ECG in Hypothermia.

    PubMed

    Arteyeva, Natalia V; Azarov, Jan E

    2017-01-01

    The changes in ventricular repolarization gradients lead to significant alterations of the electrocardiographic body surface T waves up to the T wave inversion. However, the contribution of a specific gradient remains to be elucidated. The objective of the present investigation was to study the role of the transmural repolarization gradient in the inversion of the body surface T wave with a mathematical model of the hypothermia-induced changes of ventricular repolarization. By means of mathematical simulation, we set the hypothermic action potential duration (APD) distribution on the rabbit ventricular epicardium as it was previously experimentally documented. Then the parameters of the body surface potential distribution were tested with the introduction of different scenarios of the endocardial and epicardial APD behavior in hypothermia resulting in the unchanged, reversed or enlarged transmural repolarization gradient. The reversal of epicardial repolarization gradients (apicobasal, anterior-posterior and interventricular) caused the inversion of the T waves regardless of the direction of the transmural repolarization gradient. However, the most realistic body surface potentials were obtained when the endocardial APDs were not changed under hypothermia while the epicardial APDs prolonged. This produced the reversed and increased transmural repolarization gradient in absolute magnitude. The body surface potentials simulated under the unchanged transmural gradient were reduced in comparison to those simulated under the reversed transmural gradient. The simulations demonstrated that the transmural repolarization gradient did not play a crucial role in the cardiac electric field inversion under hypothermia, but its magnitude and direction contribute to the T wave amplitude. © 2016 Wiley Periodicals, Inc.

  12. CaMKII-dependent endoplasmic reticulum fission by whisker stimulation and during cortical spreading depolarization.

    PubMed

    Kucharz, Krzysztof; Lauritzen, Martin

    2018-04-01

    Cortical spreading depolarization waves, the cause underlying migraine aura, are also the markers and mechanism of pathology in the acutely injured human brain. Propagation of spreading depolarization wave uniquely depends on the interaction between presynaptic and postsynaptic glutamate N-methyl-d-aspartate receptors (NMDARs). In the normally perfused brain, even a single wave causes a massive depolarization of neurons and glia, which results in transient loss of neuronal function and depression of the ongoing electrocorticographic activity. Endoplasmic reticulum is the cellular organelle of particular importance for modulation of neurotransmission. Neuronal endoplasmic reticulum structure is assumed to be persistently continuous in neurons, but is rapidly lost within 1 to 2 min of global cerebral ischaemia, i.e. the organelle disintegrates by fission. This phenomenon appears to be timed with the cardiac arrest-induced cortical spreading depolarizations, rather than ensuing cell death. To what extent NMDAR-dependent processes may trigger neuronal endoplasmic reticulum fission and whether fission is reversible in the normally perfused brain is unknown. We used two-photon microscopy to examine neuronal endoplasmic reticulum structural dynamics during whisker stimulation and cortical spreading depolarizations in vivo. Somatosensory stimulation triggered loss of endoplasmic reticulum continuity, a likely outcome of constriction and fission, in dendritic spines within less than 10 s of stimulation, which was spontaneously reversible and recovery to normal took 5 min. The endoplasmic reticulum fission was inhibited by blockade of NMDAR and Ca2+/calmodulin-dependent protein kinase II (CaMKII) activated downstream of the NMDARs, whereas inhibition of guanosine triphosphate hydrolases hindered regain of endoplasmic reticulum continuity, i.e. fusion. In contrast to somatosensory stimulation, endoplasmic reticulum fission during spreading depolarization was widespread and present in dendrites and spines, and was preceded by dramatic rise in intracellular Ca2+. The endoplasmic reticulum fission during spreading depolarization was more persistent, as 1 h after the depolarization cortical neurons still exhibited loss of endoplasmic reticulum continuity. Notably, endoplasmic reticulum fission was accompanied with loss of electrocorticographic activity, whereas subsequent regain of synaptic function paralleled the organelle fusion. Furthermore, blocking CaMKII activity partly rescued endoplasmic reticulum fission and markedly shortened the recovery time of brain spontaneous activity. Thus, prevention of endoplasmic reticulum fission with CaMKII inhibitors may be a novel strategy to rescue brain function in patients with migraine and a promising therapeutic avenue in the acutely injured brain.

  13. Mexican waves in an excitable medium.

    PubMed

    Farkas, I; Helbing, D; Vicsek, T

    2002-09-12

    The Mexican wave, or La Ola, which rose to fame during the 1986 World Cup in Mexico, surges through the rows of spectators in a stadium as those in one section leap to their feet with their arms up, and then sit down again as the next section rises to repeat the motion. To interpret and quantify this collective human behaviour, we have used a variant of models that were originally developed to describe excitable media such as cardiac tissue. Modelling the reaction of the crowd to attempts to trigger the wave reveals how this phenomenon is stimulated, and may prove useful in controlling events that involve groups of excited people.

  14. Korean Guidelines for the Appropriate Use of Cardiac CT

    PubMed Central

    Kim, Young Jin; Kim, Sung Mok; Kim, Jeong A; Yang, Dong Hyun; Hong, Yoo Jin

    2015-01-01

    The development of cardiac CT has provided a non-invasive alternative to echocardiography, exercise electrocardiogram, and invasive angiography and cardiac CT continues to develop at an exponential speed even now. The appropriate use of cardiac CT may lead to improvements in the medical performances of physicians and can reduce medical costs which eventually contribute to better public health. However, until now, there has been no guideline regarding the appropriate use of cardiac CT in Korea. We intend to provide guidelines for the appropriate use of cardiac CT in heart diseases based on scientific data. The purpose of this guideline is to assist clinicians and other health professionals in the use of cardiac CT for diagnosis and treatment of heart diseases, especially in patients at high risk or suspected of heart disease. PMID:25741189

  15. Long-term safety and performance of the orbital atherectomy system for treating calcified coronary artery lesions: 5-Year follow-up in the ORBIT I trial.

    PubMed

    Bhatt, Parloop; Parikh, Parth; Patel, Apurva; Chag, Milan; Chandarana, Anish; Parikh, Roosha; Parikh, Keyur

    2015-06-01

    The ORBIT I trial, a first-in-man study, was conducted to evaluate the safety and performance of the orbital atherectomy system (OAS) in treating de novo calcified coronary lesions. Fifty patients were enrolled between May and July 2008 based on several criteria, and were treated with the OAS followed by stent placement. The safety and performance of the OAS were evaluated by procedural success, device success, and overall major adverse cardiovascular event (MACE) rates, including cardiac death, myocardial infarction (MI) and need for target lesion revascularization (TLR). Our institution enrolled and treated 33 of the 50 patients and continued follow-up for 5 years. Average age was 54 years and 91% were males. Mean lesion length was 15.9 mm. Device success was 100%, and average number of orbital atherectomy devices (OAD) used per patient was 1.3. Stents were placed directly after OAS in 31/32 patients (96.9%). All stents (average stent per lesion 1.1) were successfully deployed with 0.3% residual stenosis. The overall cumulative MACE rate was 6.1% in-hospital, 9.1% at 30 days, 12.1% at 6 months, 15.2% at 2 years, 18.2% at 3 years and 21.2% at 5 years (4 total cardiac deaths). None of the patients had Q-wave MIs. Angiographic complications were observed in 5 patients. No flow/slow flow due to distal embolization was observed. The ORBIT I trial suggests that OAS treatment continues to offer a safe and effective method to change compliance of calcified coronary lesions to facilitate optimal stent placement in these difficult-to-treat patients. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  16. Cardiovascular responses to energy drinks in a healthy population: The C-energy study.

    PubMed

    Kozik, Teri M; Shah, Sachin; Bhattacharyya, Mouchumi; Franklin, Teresa T; Connolly, Therese Farrell; Chien, Walter; Charos, George S; Pelter, Michele M

    2016-07-01

    Energy drink consumption has increased significantly over the past decade and is associated with greater than 20,000 emergency department visits per year. Most often these visits are due to cardiovascular complaints ranging from palpitations to cardiac arrest. To determine if energy drinks alter; blood pressure, electrolytes, activated bleeding time (ACT), and/or cardiac responses measured with a 12-lead electrocardiographic (ECG) Holter. Continuous ECG data was collected for five hours (30 minutes baseline and 4 hours post consumption [PC]). Subjects consumed 32 ounces of energy drink within one hour and data (vital signs and blood samples) was collected throughout the study period. Paired students t-test and a corresponding non-parametric test (Wilcoxon signed rank) were used for analysis of the data. Fourteen healthy young subjects were recruited (mean age 28.6 years). Systolic blood pressure (baseline=132, ±7.83; PC=151, ±11.21; P=.001); QTc interval (baseline=423, ±22.74; PC=503, ±24.56; P<.001); magnesium level (baseline 2.04, ± 0.09; PC=2.13, ±0.15; P=.05); and calcium level (baseline=9.31, ±.28; PC=9.52, ±.22; P=.018) significantly increased from baseline. While potassium and ACT fluctuated (some subjects increased their levels while others decreased) these changes were not significant. Eight of the fourteen subjects (57%) developed a QTc >500 milliseconds PC. Other T-wave changes were noted in 9/14 (64.3%) subjects PC. Energy drinks increased systolic blood pressure, altered electrolytes, and resulted in repolarization abnormalities. These physiological responses can lead to arrhythmias and other abnormal cardiac responses highlighting the importance that emergency room personnel assess for energy drink consumption and potential toxicity. Copyright © 2016. Published by Elsevier Inc.

  17. Parametric modelling of cardiac system multiple measurement signals: an open-source computer framework for performance evaluation of ECG, PCG and ABP event detectors.

    PubMed

    Homaeinezhad, M R; Sabetian, P; Feizollahi, A; Ghaffari, A; Rahmani, R

    2012-02-01

    The major focus of this study is to present a performance accuracy assessment framework based on mathematical modelling of cardiac system multiple measurement signals. Three mathematical algebraic subroutines with simple structural functions for synthetic generation of the synchronously triggered electrocardiogram (ECG), phonocardiogram (PCG) and arterial blood pressure (ABP) signals are described. In the case of ECG signals, normal and abnormal PQRST cycles in complicated conditions such as fascicular ventricular tachycardia, rate dependent conduction block and acute Q-wave infarctions of inferior and anterolateral walls can be simulated. Also, continuous ABP waveform with corresponding individual events such as systolic, diastolic and dicrotic pressures with normal or abnormal morphologies can be generated by another part of the model. In addition, the mathematical synthetic PCG framework is able to generate the S4-S1-S2-S3 cycles in normal and in cardiac disorder conditions such as stenosis, insufficiency, regurgitation and gallop. In the PCG model, the amplitude and frequency content (5-700 Hz) of each sound and variation patterns can be specified. The three proposed models were implemented to generate artificial signals with varies abnormality types and signal-to-noise ratios (SNR), for quantitative detection-delineation performance assessment of several ECG, PCG and ABP individual event detectors designed based on the Hilbert transform, discrete wavelet transform, geometric features such as area curve length (ACLM), the multiple higher order moments (MHOM) metric, and the principal components analysed geometric index (PCAGI). For each method the detection-delineation operating characteristics were obtained automatically in terms of sensitivity, positive predictivity and delineation (segmentation) error rms and checked by the cardiologist. The Matlab m-file script of the synthetic ECG, ABP and PCG signal generators are available in the Appendix.

  18. Imaging the Propagation of the Electromechanical Wave in Heart Failure Patients with Cardiac Resynchronization Therapy.

    PubMed

    Bunting, Ethan; Lambrakos, Litsa; Kemper, Paul; Whang, William; Garan, Hasan; Konofagou, Elisa

    2017-01-01

    Current electrocardiographic and echocardiographic measurements in heart failure (HF) do not take into account the complex interplay between electrical activation and local wall motion. The utilization of novel technologies to better characterize cardiac electromechanical behavior may lead to improved response rates with cardiac resynchronization therapy (CRT). Electromechanical wave imaging (EWI) is a noninvasive ultrasound-based technique that uses the transient deformations of the myocardium to track the intrinsic EW that precedes myocardial contraction. In this paper, we investigate the performance and reproducibility of EWI in the assessment of HF patients and CRT. EWI acquisitions were obtained in five healthy controls and 16 HF patients with and without CRT pacing. Responders (n = 8) and nonresponders (n = 8) to CRT were identified retrospectively on the basis of left ventricular (LV) reverse remodeling. Electromechanical activation maps were obtained in all patients and used to compute a quantitative parameter describing the mean LV lateral wall activation time (LWAT). Mean LWAT was increased by 52.1 ms in HF patients in native rhythm compared to controls (P < 0.01). For all HF patients, CRT pacing initiated a different electromechanical activation sequence. Responders exhibited a 56.4-ms ± 28.9-ms reduction in LWAT with CRT pacing (P < 0.01), while nonresponders showed no significant change. In this initial feasibility study, EWI was capable of characterizing local cardiac electromechanical behavior as it pertains to HF and CRT response. Activation sequences obtained with EWI allow for quantification of LV lateral wall electromechanical activation, thus providing a novel method for CRT assessment. © 2016 Wiley Periodicals, Inc.

  19. Electrocardiographic Characterization of Cardiac Hypertrophy in Mice that Overexpress the ErbB2 Receptor Tyrosine Kinase

    PubMed Central

    Sysa-Shah, Polina; Sørensen, Lars L; Abraham, M Roselle; Gabrielson, Kathleen L

    2015-01-01

    Electrocardiography is an important method for evaluation and risk stratification of patients with cardiac hypertrophy. We hypothesized that the recently developed transgenic mouse model of cardiac hypertrophy (ErbB2tg) will display distinct ECG features, enabling WT (wild type) mice to be distinguished from transgenic mice without using conventional PCR genotyping. We evaluated more than 2000 mice and developed specific criteria for genotype determination by using cageside ECG, during which unanesthetized mice were manually restrained for less than 1 min. Compared with those from WT counterparts, the ECG recordings of ErbB2tg mice were characterized by higher P- and R-wave amplitudes, broader QRS complexes, inverted T waves, and ST interval depression. Pearson's correlation matrix analysis of combined WT and ErbB2tg data revealed significant correlation between heart weight and the ECG parameters of QT interval (corrected for heart rate), QRS interval, ST height, R amplitude, P amplitude, and PR interval. In addition, the left ventricular posterior wall thickness as determined by echocardiography correlated with ECG-determined ST height, R amplitude, QRS interval; echocardiographic left ventricular mass correlated with ECG-determined ST height and PR interval. In summary, we have determined phenotypic ECG criteria to differentiate ErbB2tg from WT genotypes in 98.8% of mice. This inexpensive and time-efficient ECG-based phenotypic method might be applied to differentiate between genotypes in other rodent models of cardiac hypertrophy. Furthermore, with appropriate modifications, this method might be translated for use in other species. PMID:26310459

  20. Cardiac transplantation after bridged therapy with continuous flow left ventricular assist devices.

    PubMed

    Deo, Salil V; Sung, Kiick; Daly, Richard C; Shah, Ishan K; Altarabsheh, Salah E; Stulak, John M; Joyce, Lyle D; Boilson, Barry A; Kushwaha, Sudhir S; Park, Soon J

    2014-03-01

    Cardiac transplantation is an effective surgical therapy for end-stage heart failure. Patients (pts) may need to be bridged with a continuous flow left ventricular assist device (CF-LVAD) while on the transplant list as logistic factors like organ availability are unknown. Cardiac transplantation post-LVAD can be a surgically challenging procedure and outcome in these pts is perceived to be poorer based on experience with earlier generation pulsatile flow pumps. Data from a single institution comparing these pts with those undergoing direct transplantation in the present era of continuous flow device therapy are limited. Evaluate results of cardiac transplantation in pts bridged with a CF-LVAD (BTx) and compare outcomes with pts undergoing direct transplantation (Tx) in a single institution. From June 2007 till January 2012, 106 pts underwent cardiac transplantation. Among these, 37 (35%) pts (51±11 years; 85% male) were bridged with a CF-LVAD (BTx), while 70 (65%) comprised the Tx group (53±12 years; 72% males). The median duration of LVAD support was 227 (153,327) days. During the period of LVAD support, 10/37 (27%) pts were upgraded to status 1A and all were successfully transplanted. Median hospital stay in the BTx (14 days) was slightly longer than the Tx group (12 days) but not statistically significant (p=0.21). In-hospital mortality in the BTx (5%) and Tx (1%) were comparable (p=0.25). Estimated late survival in the BTx cohort was 94±7, 90±10 and 83±16% at the end of one, two and three years, respectively which was comparable to 97±4%, 93±6% and 89±9% for the Tx group (p=0.50). Cardiac transplantation after LVAD implant can be performed with excellent results. Patients can be supported on the left ventricular assist device even for periods close to a year with good outcome after cardiac transplantation. Copyright © 2013 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  1. Dynamic three-dimensional phase-contrast technique in MRI: application to complex flow analysis around the artificial heart valve

    NASA Astrophysics Data System (ADS)

    Kim, Soo Jeong; Lee, Dong Hyuk; Song, Inchang; Kim, Nam Gook; Park, Jae-Hyeung; Kim, JongHyo; Han, Man Chung; Min, Byong Goo

    1998-07-01

    Phase-contrast (PC) method of magnetic resonance imaging (MRI) has bee used for quantitative measurements of flow velocity and volume flow rate. It is a noninvasive technique which provides an accurate two-dimensional velocity image. Moreover, Phase Contrast Cine magnetic resonance imaging combines the flow dependent contrast of PC-MRI with the ability of cardiac cine imaging to produce images throughout the cardiac cycle. However, the accuracy of the data acquired from the single through-plane velocity encoding can be reduced by the effect of flow direction, because in many practical cases flow directions are not uniform throughout the whole region of interest. In this study, we present dynamic three-dimensional velocity vector mapping method using PC-MRI which can visualize the complex flow pattern through 3D volume rendered images displayed dynamically. The direction of velocity mapping can be selected along any three orthogonal axes. By vector summation, the three maps can be combined to form a velocity vector map that determines the velocity regardless of the flow direction. At the same time, Cine method is used to observe the dynamic change of flow. We performed a phantom study to evaluate the accuracy of the suggested PC-MRI in continuous and pulsatile flow measurement. Pulsatile flow wave form is generated by the ventricular assistant device (VAD), HEMO-PULSA (Biomedlab, Seoul, Korea). We varied flow velocity, pulsatile flow wave form, and pulsing rate. The PC-MRI-derived velocities were compared with Doppler-derived results. The velocities of the two measurements showed a significant linear correlation. Dynamic three-dimensional velocity vector mapping was carried out for two cases. First, we applied to the flow analysis around the artificial heart valve in a flat phantom. We could observe the flow pattern around the valve through the 3-dimensional cine image. Next, it is applied to the complex flow inside the polymer sac that is used as ventricle in totally implantable artificial heart (TAH). As a result we could observe the flow pattern around the valves of the sac, though complex flow can not be detected correctly in the conventional phase contrast method. In addition, we could calculate the cardiac output from TAH sac by quantitative measurement of the volume of flow across the outlet valve.

  2. Long-Term Adaptive Servo-Ventilator Treatment Prevents Cardiac Death and Improves Clinical Outcome.

    PubMed

    Imamura, Teruhiko; Kinugawa, Koichiro; Nitta, Daisuke; Komuro, Issei

    2016-01-01

    Adaptive servo-ventilation (ASV) is a recently developed, noninvasive therapeutic tool for the treatment of heart failure (HF). However, the efficacy of ASV therapy in patients with advanced HF remains uncertain, especially as regards its contribution to freedom from cardiac replacement therapy. A total of 85 patients with advanced HF (New York Heart Association [NYHA] class IV 71%, inotrope infusion-dependent 34%) refractory to guideline-directed medical therapy, received ASV therapy, irrespective of sleep-disordered breathing, at our institute between 2008 and 2014. Among these 85 patients, 46 continued ASV therapy for > 1 month (continued group), whereas 39 discontinued the therapy after < 1 month because of intolerance (discontinued group). There were no significant differences in baseline variables between the two groups. Heart rate indicating sympathetic activity, left ventricular (LV) reverse remodeling assessed by LV diastolic diameter, LV ejection fraction, and the grades of mitral and tricuspid regurgitations, HF severity assessed by NYHA class and plasma level of B-type natriuretic peptide, and end-organ dysfunction, improved significantly at 6 months following the initiation of ASV therapy (P < 0.05 for all). All-cause mortality and cardiac death rate were significantly lower during 2-year follow up in the continued group (P < 0.05 for both). In conclusion, ASV is a novel therapeutic tool prior to cardiac replacement therapy in patients with advanced HF and may prolong the period until cardiac replacement therapy becomes necessary.

  3. β-Blocker Continuation After Noncardiac Surgery

    PubMed Central

    Kwon, Steve; Thompson, Rachel; Florence, Michael; Maier, Ronald; McIntyre, Lisa; Rogers, Terry; Farrohki, Ellen; Whiteford, Mark; Flum, David R.

    2014-01-01

    Background Despite limited evidence of effect, β-blocker continuation has become a national quality improvement metric. Objective To determine the effect of β-blocker continuation on outcomes in patients undergoing elective noncardiac surgery. Design, Setting, and Patients The Surgical Care and Outcomes Assessment Program is a Washington quality improvement benchmarking initiative based on clinical data from more than 55 hospitals. Linking Surgical Care and Outcomes Assessment Program data to Washington’s hospital admission and vital status registries, we studied patients undergoing elective colorectal and bariatric surgical procedures at 38 hospitals between January 1, 2008, and December 31, 2009. Main Outcome Measures Mortality, cardiac events, and the combined adverse event of cardiac events and/or mortality. Results Of 8431 patients, 23.5% were taking β-blockers prior to surgery (mean [SD] age, 61.9 [13.7] years; 63.1% were women). Treatment with β-blockers was continued on the day of surgery and during the postoperative period in 66.0% of patients. Continuation of β-blockers both on the day of surgery and postoperatively improved from 57.2% in the first quarter of 2008 to 71.3% in the fourth quarter of 2009 (P value <.001). After adjusting for risk characteristics, failure to continue β-blocker treatment was associated with a nearly 2-fold risk of 90-day combined adverse event (odds ratio, 1.97; 95% CI, 1.19-3.26). The odds were even greater among patients with higher cardiac risk (odds ratio, 5.91; 95% CI, 1.40-25.00). The odds of combined adverse events continued to be elevated 1 year postoperatively (odds ratio, 1.66; 95% CI, 1.08-2.55). Conclusions β-Blocker continuation on the day of and after surgery was associated with fewer cardiac events and lower 90-day mortality. A focus on β-blocker continuation is a worthwhile quality improvement target and should improve patient outcomes. PMID:22249847

  4. Evaluation of clinical and electrocardiographic changes during the euthanasia of horses.

    PubMed

    Buhl, R; Andersen, L O F; Karlshøj, M; Kanters, J K

    2013-06-01

    The objective of this prospective field study was to investigate whether commonly used criteria for clinical death occurred at the same time as cardiac death, as determined by electrocardiography. Specific ECG changes during euthanasia were also studied. Twenty-nine horses were euthanized with pentobarbital at two different dose rates and 15 of the 29 horses also received detomidine hydrochloride for sedation. ECG was recorded prior to and during euthanasia. Time to collapse, cessation of reflexes, heart sounds and asystole were recorded. ECG recordings were used to calculate RR intervals, PQ duration, QRS duration, distance from QRS complex to end of T wave corrected for HR (QTc interval), duration of T-wave from peak to end (TpeakTend) and amplitudes of T wave (Tpeak) before and during euthanasia. Differences between groups and ECG changes were evaluated using analysis of variance. Clinical determination of death occurred before cardiac death (P<0.05). Sedated horses took longer to collapse than unsedated horses (P<0.0001), but asystole occurred faster in sedated horses (P<0.0001). No significant changes in QRS duration were observed, but RR, PQ, QTc, TpeakTend and Tpeak were influenced by both pentobarbital dose and sedation (P<0.05-<0.0001). In conclusion, sedation prior to euthanasia resulted in a shorter time to asystole and is therefore recommended for the euthanasia of horses. Importantly, the results show that the clinical definition of death occurred significantly earlier than cardiac death (defined as asystole), which indicates that the clinical declaration of death in horses could be premature compared to that used in humans. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. A Discrete Electromechanical Model for Human Cardiac Tissue: Effects of Stretch-Activated Currents and Stretch Conditions on Restitution Properties and Spiral Wave Dynamics

    PubMed Central

    Weise, Louis D.; Panfilov, Alexander V.

    2013-01-01

    We introduce an electromechanical model for human cardiac tissue which couples a biophysical model of cardiac excitation (Tusscher, Noble, Noble, Panfilov, 2006) and tension development (adjusted Niederer, Hunter, Smith, 2006 model) with a discrete elastic mass-lattice model. The equations for the excitation processes are solved with a finite difference approach, and the equations of the mass-lattice model are solved using Verlet integration. This allows the coupled problem to be solved with high numerical resolution. Passive mechanical properties of the mass-lattice model are described by a generalized Hooke's law for finite deformations (Seth material). Active mechanical contraction is initiated by changes of the intracellular calcium concentration, which is a variable of the electrical model. Mechanical deformation feeds back on the electrophysiology via stretch-activated ion channels whose conductivity is controlled by the local stretch of the medium. We apply the model to study how stretch-activated currents affect the action potential shape, restitution properties, and dynamics of spiral waves, under constant stretch, and dynamic stretch caused by active mechanical contraction. We find that stretch conditions substantially affect these properties via stretch-activated currents. In constantly stretched medium, we observe a substantial decrease in conduction velocity, and an increase of action potential duration; whereas, with dynamic stretch, action potential duration is increased only slightly, and the conduction velocity restitution curve becomes biphasic. Moreover, in constantly stretched medium, we find an increase of the core size and period of a spiral wave, but no change in rotation dynamics; in contrast, in the dynamically stretching medium, we observe spiral drift. Our results may be important to understand how altered stretch conditions affect the heart's functioning. PMID:23527160

  6. A discrete electromechanical model for human cardiac tissue: effects of stretch-activated currents and stretch conditions on restitution properties and spiral wave dynamics.

    PubMed

    Weise, Louis D; Panfilov, Alexander V

    2013-01-01

    We introduce an electromechanical model for human cardiac tissue which couples a biophysical model of cardiac excitation (Tusscher, Noble, Noble, Panfilov, 2006) and tension development (adjusted Niederer, Hunter, Smith, 2006 model) with a discrete elastic mass-lattice model. The equations for the excitation processes are solved with a finite difference approach, and the equations of the mass-lattice model are solved using Verlet integration. This allows the coupled problem to be solved with high numerical resolution. Passive mechanical properties of the mass-lattice model are described by a generalized Hooke's law for finite deformations (Seth material). Active mechanical contraction is initiated by changes of the intracellular calcium concentration, which is a variable of the electrical model. Mechanical deformation feeds back on the electrophysiology via stretch-activated ion channels whose conductivity is controlled by the local stretch of the medium. We apply the model to study how stretch-activated currents affect the action potential shape, restitution properties, and dynamics of spiral waves, under constant stretch, and dynamic stretch caused by active mechanical contraction. We find that stretch conditions substantially affect these properties via stretch-activated currents. In constantly stretched medium, we observe a substantial decrease in conduction velocity, and an increase of action potential duration; whereas, with dynamic stretch, action potential duration is increased only slightly, and the conduction velocity restitution curve becomes biphasic. Moreover, in constantly stretched medium, we find an increase of the core size and period of a spiral wave, but no change in rotation dynamics; in contrast, in the dynamically stretching medium, we observe spiral drift. Our results may be important to understand how altered stretch conditions affect the heart's functioning.

  7. Longitudinal changes in late systolic cardiac load and serum NT-proBNP levels in healthy middle-aged Japanese men.

    PubMed

    Tomiyama, Hirofumi; Nishikimi, Toshio; Matsumoto, Chisa; Kimura, Kazutaka; Odaira, Mari; Shiina, Kazuki; Yamashina, Akira

    2015-04-01

    We determined whether any significant association exists between change in late systolic cardiac load with time, estimated by radial pressure waveform analysis, and development of cardiac hemodynamic stress in individuals with preserved cardiac function. Brachial-ankle pulse wave velocity, radial augmentation index (rAI), first peak of the radial pressure waveform (SP1), systolic and pulse pressure at the second peak of the radial pressure waveform (SP2 and PP2), and serum levels of N-terminal fragment B-type natriuretic peptide (NT-proBNP) were measured at the start (first examination) and at the end (second examination) of this 3-year study in healthy Japanese men (n = 1,851). A stepwise multivariate linear regression analysis demonstrated that among the parameters of radial pressure waveform analysis and markers of arterial stiffness analyzed, only PP2 was significantly associated with serum NT-proBNP levels in study participants at both the first and second examinations. Furthermore, among the parameters analyzed, only change in PP2 was significantly correlated with the change in serum NT-proBNP levels during the study period (beta = 0.131, P < 0.001). Sustained late systolic cardiac load might be a more significant determinant of the development of cardiac hemodynamic stress than sustained early systolic cardiac load or arterial stiffening in individuals with preserved cardiac function. © American Journal of Hypertension, Ltd 2014. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. The Multi-Domain Fibroblast/Myocyte Coupling in the Cardiac Tissue: A Theoretical Study.

    PubMed

    Greisas, Ariel; Zlochiver, Sharon

    2016-09-01

    Cardiac fibroblast proliferation and concomitant collagenous matrix accumulation (fibrosis) develop during multiple cardiac pathologies. Recent studies have demonstrated direct electrical coupling between myocytes and fibroblasts in vitro, and assessed the electrophysiological implications of such coupling. However, in the living tissues, such coupling has not been demonstrated, and only indirect coupling via the extracellular space is likely to exist. In this study we employed a multi-domain model to assess the modulation of the cardiac electrophysiological properties by neighboring fibroblasts assuming only indirect coupling. Numerical simulations in 1D and 2D human atrial models showed that extracellular coupling sustains a significant impact on conduction velocity (CV) and a less significant effect on the action potential duration. Both CV and the slope of the CV restitution increased with increasing fibroblast density. This effect was more substantial for lower extracellular conductance. In 2D, spiral waves exhibited reduced frequency with increasing fibroblast density, and the propensity of wavebreaks and complex dynamics at high pacing rates significantly increased.

  9. Continuous Intravenous Milrinone Therapy in Pediatric Outpatients.

    PubMed

    Curley, Michelle; Liebers, Jill; Maynard, Roy

    Milrinone is a phosphodiesterase 3 inhibitor with both positive inotropic and vasodilator properties. Administered as a continuous infusion, milrinone is indicated for the short-term treatment of patients with acute decompensated heart failure. Despite limited data supporting long-term milrinone therapy in adults with congestive heart failure, children managed as outpatients may benefit from continuous milrinone as a treatment for cardiac dysfunction, as a destination therapy for cardiac transplant, or as palliative therapy for cardiomyopathy. The aim of this article is to review the medical literature and describe a home infusion company's experience with pediatric outpatient milrinone therapy.

  10. Continuous Intravenous Milrinone Therapy in Pediatric Outpatients

    PubMed Central

    Curley, Michelle; Liebers, Jill

    2017-01-01

    Milrinone is a phosphodiesterase 3 inhibitor with both positive inotropic and vasodilator properties. Administered as a continuous infusion, milrinone is indicated for the short-term treatment of patients with acute decompensated heart failure. Despite limited data supporting long-term milrinone therapy in adults with congestive heart failure, children managed as outpatients may benefit from continuous milrinone as a treatment for cardiac dysfunction, as a destination therapy for cardiac transplant, or as palliative therapy for cardiomyopathy. The aim of this article is to review the medical literature and describe a home infusion company's experience with pediatric outpatient milrinone therapy. PMID:28248808

  11. Architecture design of the multi-functional wavelet-based ECG microprocessor for realtime detection of abnormal cardiac events.

    PubMed

    Cheng, Li-Fang; Chen, Tung-Chien; Chen, Liang-Gee

    2012-01-01

    Most of the abnormal cardiac events such as myocardial ischemia, acute myocardial infarction (AMI) and fatal arrhythmia can be diagnosed through continuous electrocardiogram (ECG) analysis. According to recent clinical research, early detection and alarming of such cardiac events can reduce the time delay to the hospital, and the clinical outcomes of these individuals can be greatly improved. Therefore, it would be helpful if there is a long-term ECG monitoring system with the ability to identify abnormal cardiac events and provide realtime warning for the users. The combination of the wireless body area sensor network (BASN) and the on-sensor ECG processor is a possible solution for this application. In this paper, we aim to design and implement a digital signal processor that is suitable for continuous ECG monitoring and alarming based on the continuous wavelet transform (CWT) through the proposed architectures--using both programmable RISC processor and application specific integrated circuits (ASIC) for performance optimization. According to the implementation results, the power consumption of the proposed processor integrated with an ASIC for CWT computation is only 79.4 mW. Compared with the single-RISC processor, about 91.6% of the power reduction is achieved.

  12. Cardiac Amyloidosis Shows Decreased Diastolic Function as Assessed by Echocardiographic Parameterized Diastolic Filling.

    PubMed

    Salman, Katrin; Cain, Peter A; Fitzgerald, Benjamin T; Sundqvist, Martin G; Ugander, Martin

    2017-07-01

    Cardiac amyloidosis is a rare but serious condition with poor survival. One of the early findings by echocardiography is impaired diastolic function, even before the development of cardiac symptoms. Early diagnosis is important, permitting initiation of treatment aimed at improving survival. The parameterized diastolic filling (PDF) formalism entails describing the left ventricular filling pattern during early diastole using the mathematical equation for the motion of a damped harmonic oscillator. We hypothesized that echocardiographic PDF analysis could detect differences in diastolic function between patients with amyloidosis and controls. Pulsed-wave Doppler echocardiography of transmitral flow was measured in 13 patients with amyloid heart disease and 13 age- and gender matched controls. E- waves (2 to 3 per subject) were analyzed using in-house developed software. Nine PDF-derived parameters were obtained in addition to conventional echocardiographic parameters of diastolic function. Compared to controls, cardiac amyloidosis patients had a larger left atrial area (23.7 ± 7.5 cm 2 vs. 18.5 ± 4.8 cm 2 , p = 0.04), greater interventricular septum wall thickness (14.4 ± 2.6 mm vs. 9.3 ± 1.3 mm, p < 0.001), lower e' (0.06 ± 0.02 m/s vs. 0.09 ± 0.02 m/s, p < 0.001) and higher E/e' (18.0 ± 12.9 vs. 7.7 ± 1.3, p = 0.001). The PDF parameter peak resistive force was greater in cardiac amyloidosis patients compared to controls (17.9 ± 5.7 mN vs. 13.1 ± 3.1 mN, p = 0.03), and other PDF parameters did not differ. PDF analysis revealed that patients with cardiac amyloidosis had a greater peak resistive force compared to controls, consistent with a greater degree of diastolic dysfunction. PDF analysis may be useful in characterizing diastolic function in amyloid heart disease. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  13. Increased Non-conducted P-wave Arrhythmias after a Single Oil Fly Ash Inhalation Exposure in Hypertensive Rats

    EPA Science Inventory

    Exposure to combustion-derived fine particulate matter (PM) is associated with increased cardiovascular morbidity and mortality especially in individuals with cardiovascular disease, including hypertension. PM inhalation causes several adverse changes in cardiac function that ar...

  14. A Numerical Study of Scalable Cardiac Electro-Mechanical Solvers on HPC Architectures

    PubMed Central

    Colli Franzone, Piero; Pavarino, Luca F.; Scacchi, Simone

    2018-01-01

    We introduce and study some scalable domain decomposition preconditioners for cardiac electro-mechanical 3D simulations on parallel HPC (High Performance Computing) architectures. The electro-mechanical model of the cardiac tissue is composed of four coupled sub-models: (1) the static finite elasticity equations for the transversely isotropic deformation of the cardiac tissue; (2) the active tension model describing the dynamics of the intracellular calcium, cross-bridge binding and myofilament tension; (3) the anisotropic Bidomain model describing the evolution of the intra- and extra-cellular potentials in the deforming cardiac tissue; and (4) the ionic membrane model describing the dynamics of ionic currents, gating variables, ionic concentrations and stretch-activated channels. This strongly coupled electro-mechanical model is discretized in time with a splitting semi-implicit technique and in space with isoparametric finite elements. The resulting scalable parallel solver is based on Multilevel Additive Schwarz preconditioners for the solution of the Bidomain system and on BDDC preconditioned Newton-Krylov solvers for the non-linear finite elasticity system. The results of several 3D parallel simulations show the scalability of both linear and non-linear solvers and their application to the study of both physiological excitation-contraction cardiac dynamics and re-entrant waves in the presence of different mechano-electrical feedbacks. PMID:29674971

  15. Malignant Course of Anomalous Left Coronary Artery Causing Sudden Cardiac Arrest: A Case Report and Review of the Literature.

    PubMed

    Anantha Narayanan, Mahesh; DeZorzi, Christopher; Akinapelli, Abhilash; Mahfood Haddad, Toufik; Smer, Aiman; Baskaran, Janani; Biddle, William P

    2015-01-01

    Sudden cardiac arrest has been reported to occur in patients with congenital anomalous coronary artery disease. About 80% of the anomalies are benign and incidental findings at the time of catheterization. We present a case of sudden cardiac arrest caused by anomalous left anterior descending artery. 61-year-old African American female was brought to the emergency department after sudden cardiac arrest. Initial EKG showed sinus rhythm with RBBB and LAFB with nonspecific ST-T wave changes. Coronary angiogram revealed no atherosclerotic disease. The left coronary artery was found to originate from the right coronary cusp. Cardiac CAT scan revealed similar findings with interarterial and intramural course. Patient received one-vessel arterial bypass graft to her anomalous coronary vessel along with a defibrillator for secondary prevention. Sudden cardiac arrest secondary to congenital anomalous coronary artery disease is characterized by insufficient coronary flow by the anomalous left coronary artery to meet elevated left ventricular (LV) myocardial demand. High risk defects include those involved with the proximal coronary artery or coursing of the anomalous artery between the aorta and pulmonary trunk. Per guidelines, our patient received one vessel bypass graft to her anomalous vessel. It is important for clinicians to recognize such presentations of anomalous coronary artery.

  16. Emergent dynamics of spatio-temporal chaos in a heterogeneous excitable medium.

    PubMed

    Bittihn, Philip; Berg, Sebastian; Parlitz, Ulrich; Luther, Stefan

    2017-09-01

    Self-organized activation patterns in excitable media such as spiral waves and spatio-temporal chaos underlie dangerous cardiac arrhythmias. While the interaction of single spiral waves with different types of heterogeneity has been studied extensively, the effect of heterogeneity on fully developed spatio-temporal chaos remains poorly understood. We investigate how the complexity and stability properties of spatio-temporal chaos in the Bär-Eiswirth model of excitable media depend on the heterogeneity of the underlying medium. We employ different measures characterizing the chaoticity of the system and find that the spatial arrangement of multiple discrete lower excitability regions has a strong impact on the complexity of the dynamics. Varying the number, shape, and spatial arrangement of the heterogeneities, we observe strong emergent effects ranging from increases in chaoticity to the complete cessation of chaos, contrasting the expectation from the homogeneous behavior. The implications of our findings for the development and treatment of arrhythmias in the heterogeneous cardiac muscle are discussed.

  17. Emergent dynamics of spatio-temporal chaos in a heterogeneous excitable medium

    NASA Astrophysics Data System (ADS)

    Bittihn, Philip; Berg, Sebastian; Parlitz, Ulrich; Luther, Stefan

    2017-09-01

    Self-organized activation patterns in excitable media such as spiral waves and spatio-temporal chaos underlie dangerous cardiac arrhythmias. While the interaction of single spiral waves with different types of heterogeneity has been studied extensively, the effect of heterogeneity on fully developed spatio-temporal chaos remains poorly understood. We investigate how the complexity and stability properties of spatio-temporal chaos in the Bär-Eiswirth model of excitable media depend on the heterogeneity of the underlying medium. We employ different measures characterizing the chaoticity of the system and find that the spatial arrangement of multiple discrete lower excitability regions has a strong impact on the complexity of the dynamics. Varying the number, shape, and spatial arrangement of the heterogeneities, we observe strong emergent effects ranging from increases in chaoticity to the complete cessation of chaos, contrasting the expectation from the homogeneous behavior. The implications of our findings for the development and treatment of arrhythmias in the heterogeneous cardiac muscle are discussed.

  18. Deduction of two-dimensional blood flow vector by dual angle diverging waves from a cardiac sector probe

    NASA Astrophysics Data System (ADS)

    Maeda, Moe; Nagaoka, Ryo; Ikeda, Hayato; Yaegashi, So; Saijo, Yoshifumi

    2018-07-01

    Color Doppler method is widely used for noninvasive diagnosis of heart diseases. However, the method can measure one-dimensional (1D) blood flow velocity only along an ultrasonic beam. In this study, diverging waves with two different angles were irradiated from a cardiac sector probe to estimate a two-dimensional (2D) blood flow vector from each velocity measured with the angles. The feasibility of the proposed method was evaluated in experiments using flow poly(vinyl alcohol) (PVA) gel phantoms. The 2D velocity vectors obtained with the proposed method were compared with the flow vectors obtained with the particle image velocimetry (PIV) method. Root mean square errors of the axial and lateral components were 11.3 and 29.5 mm/s, respectively. The proposed method was also applied to echo data from the left ventricle of the heart. The inflow from the mitral valve in diastole and the ejection flow concentrating in the aorta in systole were visualized.

  19. Probing myocardium biomechanics using quantitative optical coherence elastography

    NASA Astrophysics Data System (ADS)

    Wang, Shang; Lopez, Andrew L.; Morikawa, Yuka; Tao, Ge; Li, Jiasong; Larina, Irina V.; Martin, James F.; Larin, Kirill V.

    2015-03-01

    We present a quantitative optical coherence elastographic method for noncontact assessment of the myocardium elasticity. The method is based on shear wave imaging optical coherence tomography (SWI-OCT), where a focused air-puff system is used to induce localized tissue deformation through a low-pressure short-duration air stream and a phase-sensitive OCT system is utilized to monitor the propagation of the induced tissue displacement with nanoscale sensitivity. The 1-D scanning of M-mode OCT imaging and the application of optical phase retrieval and mapping techniques enable the reconstruction and visualization of 2-D depth-resolved shear wave propagation in tissue with ultra-high frame rate. The feasibility of this method in quantitative elasticity measurement is demonstrated on tissue-mimicking phantoms with the estimated Young's modulus compared with uniaxial compression tests. We also performed pilot experiments on ex vivo mouse cardiac muscle tissues with normal and genetically altered cardiomyocytes. Our results indicate this noncontact quantitative optical coherence elastographic method can be a useful tool for the cardiac muscle research and studies.

  20. Effect of PFDA on Cardiac Membrane Function.

    DTIC Science & Technology

    1983-03-01

    NO. 3. RECIPIENT’S CATALOG NUMBER AFOS-TR - / .... 4. TITLE (and Subtitle) 5. TVPF nF REPORT & PERIOD COVERED EFFECT OF PFDA ON CARDIAC MEMBRANE...Continue on reverse side II necessary and Identify by block number) Heart, Thyroxine, Triiodothyronine, PFDA 0t C) 20, ABSTRACT (Continue on revereD...eide If neceesary and Identify by block number) LTJ "Yihe in vivo and in vitro heart rates of rats treated with 75 mg/kg PFDA was __j significantly

  1. Correlations between electrocardiogram and biomarkers in acute pulmonary embolism: Analysis of ZATPOL-2 Registry.

    PubMed

    Kukla, Piotr; Kosior, Dariusz A; Tomaszewski, Andrzej; Ptaszyńska-Kopczyńska, Katarzyna; Widejko, Katarzyna; Długopolski, Robert; Skrzyński, Andrzej; Błaszczak, Piotr; Fijorek, Kamil; Kurzyna, Marcin

    2017-07-01

    Electrocardiography (ECG) is still one of the first tests performed at admission, mostly in patients (pts) with chest pain or dyspnea. The aim of this study was to assess the correlation between electrocardiographic abnormalities and cardiac biomarkers as well as echocardiographic parameter in patients with acute pulmonary embolism. We performed a retrospective analysis of 614 pts. (F/M 334/280; mean age of 67.9 ± 16.6 years) with confirmed acute pulmonary embolism (APE) who were enrolled to the ZATPOL-2 Registry between 2012 and 2014. Elevated cardiac biomarkers were observed in 358 pts (74.4%). In this group the presence of atrial fibrillation (p = .008), right axis deviation (p = .004), S 1 Q 3 T 3 sign (p < .001), RBBB (p = .006), ST segment depression in leads V 4 -V 6 (p < .001), ST segment depression in lead I (p = .01), negative T waves in leads V 1 -V 3 (p < .001), negative T waves in leads V 4 -V 6 (p = .005), negative T waves in leads II, III and aVF (p = .005), ST segment elevation in lead aVR (p = .002), ST segment elevation in lead III (p = .0038) was significantly more frequent in comparison to subjects with normal serum level of cardiac biomarkers. In multivariate regression analysis, clinical predictors of "abnormal electrocardiogram" were as follows: increased heart rate (OR 1.09, 95% CI 1.02-1.17, p = .012), elevated troponin concentration (OR 3.33, 95% CI 1.94-5.72, p = .000), and right ventricular overload (OR 2.30, 95% CI 1.17-4.53, p = .016). Electrocardiographic signs of right ventricular strain are strongly related to elevated cardiac biomarkers and echocardiographic signs of right ventricular overload. ECG may be used in preliminary risk stratification of patient with intermediate- or high-risk forms of APE. © 2017 Wiley Periodicals, Inc.

  2. Nuclear cardiac

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Slutsky, R.; Ashburn, W.L.

    1982-01-01

    The relationship between nuclear medicine and cardiology has continued to produce a surfeit of interesting, illuminating, and important reports involving the analysis of cardiac function, perfusion, and metabolism. To simplify the presentation, this review is broken down into three major subheadings: analysis of myocardial perfusion; imaging of the recent myocardial infarction; and the evaluation of myocardial function. There appears to be an increasingly important relationship between cardiology, particularly cardiac physiology, and nuclear imaging techniques. (KRM)

  3. Trajectory of coronary motion and its significance in robotic motion cancellation.

    PubMed

    Cattin, Philippe; Dave, Hitendu; Grünenfelder, Jürg; Szekely, Gabor; Turina, Marko; Zünd, Gregor

    2004-05-01

    To characterize remaining coronary artery motion of beating pig hearts after stabilization with an 'Octopus' using an optical remote analysis technique. Three pigs (40, 60 and 65 kg) underwent full sternotomy after receiving general anesthesia. An 8-bit high speed black and white video camera (50 frames/s) coupled with a laser sensor (60 microm resolution) were used to capture heart wall motion in all three dimensions. Dopamine infusion was used to deliberately modulate cardiac contractility. Synchronized ECG, blood pressure, airway pressure and video data of the region around the first branching point of the left anterior descending (LAD) coronary artery after Octopus stabilization were captured for stretches of 8 s each. Several sequences of the same region were captured over a period of several minutes. Computerized off-line analysis allowed us to perform minute characterization of the heart wall motion. The movement of the points of interest on the LAD ranged from 0.22 to 0.81 mm in the lateral plane (x/y-axis) and 0.5-2.6 mm out of the plane (z-axis). Fast excursions (>50 microm/s in the lateral plane) occurred corresponding to the QRS complex and the T wave; while slow excursion phases (<50 microm/s in the lateral plane) were observed during the P wave and the ST segment. The trajectories of the points of interest during consecutive cardiac cycles as well as during cardiac cycles minutes apart remained comparable (the differences were negligible), provided the hemodynamics remained stable. Inotrope-induced changes in cardiac contractility influenced not only the maximum excursion, but also the shape of the trajectory. Normal positive pressure ventilation displacing the heart in the thoracic cage was evident by the displacement of the reference point of the trajectory. The movement of the coronary artery after stabilization appears to be still significant. Minute characterization of the trajectory of motion could provide the substrate for achieving motion cancellation for existing robotic systems. Velocity plots could also help improve gated cardiac imaging.

  4. The Murine Model of Mucopolysaccharidosis IIIB Develops Cardiopathies over Time Leading to Heart Failure

    PubMed Central

    De Pasquale, Valeria; Cocchiaro, Pasquale; Paciello, Orlando; Avallone, Luigi; Belfiore, Maria Paola; Iacobellis, Francesca; Di Napoli, Daniele; Magliulo, Fabio; Perrino, Cinzia; Trimarco, Bruno; Esposito, Giovanni; Di Natale, Paola; Pavone, Luigi Michele

    2015-01-01

    Mucopolysaccharidosis (MPS) IIIB is a lysosomal disease due to the deficiency of the enzyme α-N-acetylglucosaminidase (NAGLU) required for heparan sulfate (HS) degradation. The disease is characterized by mild somatic features and severe neurological disorders. Very little is known on the cardiac dysfunctions in MPS IIIB. In this study, we used the murine model of MPS IIIB (NAGLU knockout mice, NAGLU-/-) in order to investigate the cardiac involvement in the disease. Echocardiographic analysis showed a marked increase in left ventricular (LV) mass, reduced cardiac function and valvular defects in NAGLU-/- mice as compared to wild-type (WT) littermates. The NAGLU-/- mice exhibited a significant increase in aortic and mitral annulus dimension with a progressive elongation and thickening of anterior mitral valve leaflet. A severe mitral regurgitation with reduction in mitral inflow E-wave-to-A-wave ratio was observed in 32-week-old NAGLU-/- mice. Compared to WT mice, NAGLU-/- mice exhibited a significantly lower survival with increased mortality observed in particular after 25 weeks of age. Histopathological analysis revealed a significant increase of myocardial fiber vacuolization, accumulation of HS in the myocardial vacuoles, recruitment of inflammatory cells and collagen deposition within the myocardium, and an increase of LV fibrosis in NAGLU-/- mice compared to WT mice. Biochemical analysis of heart samples from affected mice showed increased expression levels of cardiac failure hallmarks such as calcium/calmodulin-dependent protein kinase II, connexin43, α-smooth muscle actin, α-actinin, atrial and brain natriuretic peptides, and myosin heavy polypeptide 7. Furthermore, heart samples from NAGLU-/- mice showed enhanced expression of the lysosome-associated membrane protein-2 (LAMP2), and the autophagic markers Beclin1 and LC3 isoform II (LC3-II). Overall, our findings demonstrate that NAGLU-/- mice develop heart disease, valvular abnormalities and cardiac failure associated with an impaired lysosomal autophagic flux. PMID:26147524

  5. Comparison of an oscillometric method with cardiac magnetic resonance for the analysis of aortic pulse wave velocity.

    PubMed

    Feistritzer, Hans-Josef; Reinstadler, Sebastian J; Klug, Gert; Kremser, Christian; Seidner, Benjamin; Esterhammer, Regina; Schocke, Michael F; Franz, Wolfgang-Michael; Metzler, Bernhard

    2015-01-01

    Pulse wave velocity (PWV) is the proposed gold-standard for the assessment of aortic elastic properties. The aim of this study was to compare aortic PWV determined by a recently developed oscillometric device with cardiac magnetic resonance imaging (CMR). PWV was assessed in 40 volunteers with two different methods. The oscillometric method (PWVOSC) is based on a transfer function from the brachial pressure waves determined by oscillometric blood pressure measurements with a common cuff (Mobil-O-Graph, I.E.M. Stolberg, Germany). CMR was used to determine aortic PWVCMR with the use of the transit time method based on phase-contrast imaging at the level of the ascending and abdominal aorta on a clinical 1.5 Tesla scanner (Siemens, Erlangen, Germany). The median age of the study population was 34 years (IQR: 24-55 years, 11 females). A very strong correlation was found between PWVOSC and PWVCMR (r = 0.859, p < 0.001). Mean PWVOSC was 6.7 ± 1.8 m/s and mean PWVCMR was 6.1 ± 1.8 m/s (p < 0.001). Analysis of agreement between the two measurements using Bland-Altman method showed a bias of 0.57 m/s (upper and lower limit of agreement: 2.49 m/s and -1.34 m/s). The corresponding coefficient of variation between both measurements was 15%. Aortic pulse wave velocity assessed by transformation of the brachial pressure waveform showed an acceptable agreement with the CMR-derived transit time method.

  6. Peregrine rogue waves induced by the interaction between a continuous wave and a soliton.

    PubMed

    Yang, Guangye; Li, Lu; Jia, Suotang

    2012-04-01

    Based on the soliton solution on a continuous wave background for an integrable Hirota equation, the reduction mechanism and the characteristics of the Peregrine rogue wave in the propagation of femtosecond pulses of optical fiber are discussed. The results show that there exist two processes of the formation of the Peregrine rogue wave: one is the localized process of the continuous wave background, and the other is the reduction process of the periodization of the bright soliton. The characteristics of the Peregrine rogue wave are exhibited by strong temporal and spatial localization. Also, various initial excitations of the Peregrine rogue wave are performed and the results show that the Peregrine rogue wave can be excited by a small localized (single peak) perturbation pulse of the continuous wave background, even for the nonintegrable case. The numerical simulations show that the Peregrine rogue wave is unstable. Finally, through a realistic example, the influence of the self-frequency shift to the dynamics of the Peregrine rogue wave is discussed. The results show that in the absence of the self-frequency shift, the Peregrine rogue wave can split into several subpulses; however, when the self-frequency shift is considered, the Peregrine rogue wave no longer splits and exhibits mainly a peak changing and an increasing evolution property of the field amplitude.

  7. Cardiac tissue engineering: from matrix design to the engineering of bionic hearts.

    PubMed

    Fleischer, Sharon; Feiner, Ron; Dvir, Tal

    2017-04-01

    The field of cardiac tissue engineering aims at replacing the scar tissue created after a patient has suffered from a myocardial infarction. Various technologies have been developed toward fabricating a functional engineered tissue that closely resembles that of the native heart. While the field continues to grow and techniques for better tissue fabrication continue to emerge, several hurdles still remain to be overcome. In this review we will focus on several key advances and recent technologies developed in the field, including biomimicking the natural extracellular matrix structure and enhancing the transfer of the electrical signal. We will also discuss recent developments in the engineering of bionic cardiac tissues which integrate the fields of tissue engineering and electronics to monitor and control tissue performance.

  8. COMPARATIVE DISINFECTION EFFICIENCY OF PULSED AND CONTINUOUS-WAVE UV IRRADIATION TECHNOLOGIES

    EPA Science Inventory

    Pulsed UV (PUV) is novel UV irradiation system that is a non-mercury lamp based alternative to currently used continuous-wave systems for water disinfection. To compare the polychromatic PUV irradiation disinfection efficiency with that from continuous wave monochromatic low-pre...

  9. Myocardial effects of local shock wave therapy in a Langendorff model.

    PubMed

    Becker, M; Goetzenich, A; Roehl, A B; Huebel, C; de la Fuente, M; Dietz-Laursonn, K; Radermacher, K; Rossaint, R; Hein, M

    2014-01-01

    Applying shock waves to the heart has been reported to stimulate the heart and alter cardiac function. We hypothesized that shock waves could be used to diagnose regional viability. We used a Langendorff model to investigate the acute effects of shock waves at different energy levels and times related to systole, cycle duration and myocardial function. We found only a small time window to use shock waves. Myocardial fibrillation or extrasystolic beats will occur if the shock wave is placed more than 15 ms before or 30 ms after the onset of systole. Increased contractility and augmented relaxation were observed after the second beat, and these effects decreased after prolonging the shock wave delay from 15 ms before to 30 ms after the onset of systole. An energy dependency could be found only after short delays (-15 ms). The involved processes might include post-extrasystolic potentiation and simultaneous pacing. In summary, we found that low-energy shock waves can be a useful tool to stimulate the myocardium at a distance and influence function. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Outcomes of PCI at hospitals with or without on-site cardiac surgery.

    PubMed

    Aversano, Thomas; Lemmon, Cynthia C; Liu, Li

    2012-05-10

    Performance of percutaneous coronary intervention (PCI) is usually restricted to hospitals with cardiac surgery on site. We conducted a noninferiority trial to compare the outcomes of PCI performed at hospitals without and those with on-site cardiac surgery. We randomly assigned participants to undergo PCI at a hospital with or without on-site cardiac surgery. Patients requiring primary PCI were excluded. The trial had two primary end points: 6-week mortality and 9-month incidence of major adverse cardiac events (the composite of death, Q-wave myocardial infarction, or target-vessel revascularization). Noninferiority margins for the risk difference were 0.4 percentage points for mortality at 6 weeks and 1.8 percentage points for major adverse cardiac events at 9 months. A total of 18,867 patients were randomly assigned in a 3:1 ratio to undergo PCI at a hospital without on-site cardiac surgery (14,149 patients) or with on-site cardiac surgery (4718 patients). The 6-week mortality rate was 0.9% at hospitals without on-site surgery versus 1.0% at those with on-site surgery (difference, -0.04 percentage points; 95% confidence interval [CI], -0.31 to 0.23; P=0.004 for noninferiority). The 9-month rates of major adverse cardiac events were 12.1% and 11.2% at hospitals without and those with on-site surgery, respectively (difference, 0.92 percentage points; 95% CI, 0.04 to 1.80; P=0.05 for noninferiority). The rate of target-vessel revascularization was higher in hospitals without on-site surgery (6.5% vs. 5.4%, P=0.01). We found that PCI performed at hospitals without on-site cardiac surgery was noninferior to PCI performed at hospitals with on-site cardiac surgery with respect to mortality at 6 weeks and major adverse cardiac events at 9 months. (Funded by the Cardiovascular Patient Outcomes Research Team [C-PORT] participating sites; ClinicalTrials.gov number, NCT00549796.).

  11. Cardiac-related changes in lung resistivity as a function of frequency and location obtained from EITS images.

    PubMed

    Nopp, P; Zhao, T X; Brown, B H; Wang, W

    1996-11-01

    ECG-gated electrical impedance tomographic spectroscopy (EITS) measurements of the lungs were taken on seven normal subjects in the frequency range 9.6 kHz to 614.4 kHz. The results show that in late systole the resistivity p' relative to the R-wave (i.e. p' = 1 at the R-wave) decreases consistently within the lung. In addition there arises an increase in p' in early systole towards the periphery of the lung. Frequency behaviour of p' changes with location. At all times after the R-wave, in the centre of the lung p' is higher at higher frequency f whereas in the periphery it is lower at higher f. The principal decrease in p' can be explained by increasing pulmonary blood volume due to cardiac contraction. The early systolic increase is presumably due to venous return to the left atrium locally leading blood output from the right ventricle which is delayed by the windkessel effect. Based on a model taking extracapillary and capillary blood volume increase into account, the change in frequency behaviour of p' is explained by regional variations in extracapillary blood vessel size determining the relative contributions of extracapillary blood volume and capillary blood volume change to p' at a certain frequency.

  12. Pulse-driven magnetoimpedance sensor detection of cardiac magnetic activity.

    PubMed

    Nakayama, Shinsuke; Sawamura, Kenta; Mohri, Kaneo; Uchiyama, Tsuyoshi

    2011-01-01

    This study sought to establish a convenient method for detecting biomagnetic activity in the heart. Electrical activity of the heart simultaneously induces a magnetic field. Detection of this magnetic activity will enable non-contact, noninvasive evaluation to be made. We improved the sensitivity of a pulse-driven magnetoimpedance (PMI) sensor, which is used as an electric compass in mobile phones and as a motion sensor of the operation handle in computer games, toward a pico-Tesla (pT) level, and measured magnetic fields on the surface of the thoracic wall in humans. The changes in magnetic field detected by this sensor synchronized with the electric activity of the electrocardiogram (ECG). The shape of the magnetic wave was largely altered by shifting the sensor position within 20 mm in parallel and/or perpendicular to the thoracic wall. The magnetic activity was maximal in the 4th intercostals near the center of the sterna. Furthermore, averaging the magnetic activity at 15 mm in the distance between the thoracic wall and the sensor demonstrated magnetic waves mimicking the P wave and QRS complex. The present study shows the application of PMI sensor in detecting cardiac magnetic activity in several healthy subjects, and suggests future applications of this technology in medicine and biology.

  13. T-Wave Morphology Restitution Predicts Sudden Cardiac Death in Patients With Chronic Heart Failure.

    PubMed

    Ramírez, Julia; Orini, Michele; Mincholé, Ana; Monasterio, Violeta; Cygankiewicz, Iwona; Bayés de Luna, Antonio; Martínez, Juan Pablo; Pueyo, Esther; Laguna, Pablo

    2017-05-19

    Patients with chronic heart failure are at high risk of sudden cardiac death (SCD). Increased dispersion of repolarization restitution has been associated with SCD, and we hypothesize that this should be reflected in the morphology of the T-wave and its variations with heart rate. The aim of this study is to propose an electrocardiogram (ECG)-based index characterizing T-wave morphology restitution (TMR), and to assess its association with SCD risk in a population of chronic heart failure patients. Holter ECGs from 651 ambulatory patients with chronic heart failure from the MUSIC (MUerte Súbita en Insuficiencia Cardiaca) study were available for the analysis. TMR was quantified by measuring the morphological variation of the T-wave per RR increment using time-warping metrics, and its predictive power was compared to that of clinical variables such as the left ventricular ejection fraction and other ECG-derived indices, such as T-wave alternans and heart rate variability. TMR was significantly higher in SCD victims than in the rest of patients (median 0.046 versus 0.039, P <0.001). When TMR was dichotomized at TMR=0.040, the SCD rate was significantly higher in the TMR≥0.040 group ( P <0.001). Cox analysis revealed that TMR≥0.040 was strongly associated with SCD, with a hazard ratio of 3.27 ( P <0.001), independently of clinical and ECG-derived variables. No association was found between TMR and pump failure death. This study shows that TMR is specifically associated with SCD in a population of chronic heart failure patients, and it is a better predictor than clinical and ECG-derived variables. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  14. 3D Finite Element Electrical Model of Larval Zebrafish ECG Signals

    PubMed Central

    Crowcombe, James; Dhillon, Sundeep Singh; Hurst, Rhiannon Mary; Egginton, Stuart; Müller, Ferenc; Sík, Attila; Tarte, Edward

    2016-01-01

    Assessment of heart function in zebrafish larvae using electrocardiography (ECG) is a potentially useful tool in developing cardiac treatments and the assessment of drug therapies. In order to better understand how a measured ECG waveform is related to the structure of the heart, its position within the larva and the position of the electrodes, a 3D model of a 3 days post fertilisation (dpf) larval zebrafish was developed to simulate cardiac electrical activity and investigate the voltage distribution throughout the body. The geometry consisted of two main components; the zebrafish body was modelled as a homogeneous volume, while the heart was split into five distinct regions (sinoatrial region, atrial wall, atrioventricular band, ventricular wall and heart chambers). Similarly, the electrical model consisted of two parts with the body described by Laplace’s equation and the heart using a bidomain ionic model based upon the Fitzhugh-Nagumo equations. Each region of the heart was differentiated by action potential (AP) parameters and activation wave conduction velocities, which were fitted and scaled based on previously published experimental results. ECG measurements in vivo at different electrode recording positions were then compared to the model results. The model was able to simulate action potentials, wave propagation and all the major features (P wave, R wave, T wave) of the ECG, as well as polarity of the peaks observed at each position. This model was based upon our current understanding of the structure of the normal zebrafish larval heart. Further development would enable us to incorporate features associated with the diseased heart and hence assist in the interpretation of larval zebrafish ECGs in these conditions. PMID:27824910

  15. Controlling three-dimensional vortices using multiple and moving external fields

    NASA Astrophysics Data System (ADS)

    Das, Nirmali Prabha; Dutta, Sumana

    2017-08-01

    Spirals or scroll wave activities in cardiac tissues are the cause of lethal arrhythmias. The external control of these waves is thus of prime interest to scientists and physicians. In this article, we demonstrate the spatial control of scroll waves by using external electric fields and thermal gradients in experiments with the Belousov-Zhabotinsky reaction. We show that a scroll ring can be made to trace cyclic trajectories under a rotating electric field. Application of a thermal gradient in addition to the electric field deflects the motion and changes the nature of the trajectory. Our experimental results are analyzed and corroborated by numerical simulations based on an excitable reaction diffusion model.

  16. Comparison of Regression Analysis and Transfer Function in Estimating the Parameters of Central Pulse Waves from Brachial Pulse Wave.

    PubMed

    Chai, Rui; Xu, Li-Sheng; Yao, Yang; Hao, Li-Ling; Qi, Lin

    2017-01-01

    This study analyzed ascending branch slope (A_slope), dicrotic notch height (Hn), diastolic area (Ad) and systolic area (As) diastolic blood pressure (DBP), systolic blood pressure (SBP), pulse pressure (PP), subendocardial viability ratio (SEVR), waveform parameter (k), stroke volume (SV), cardiac output (CO), and peripheral resistance (RS) of central pulse wave invasively and non-invasively measured. Invasively measured parameters were compared with parameters measured from brachial pulse waves by regression model and transfer function model. Accuracy of parameters estimated by regression and transfer function model, was compared too. Findings showed that k value, central pulse wave and brachial pulse wave parameters invasively measured, correlated positively. Regression model parameters including A_slope, DBP, SEVR, and transfer function model parameters had good consistency with parameters invasively measured. They had same effect of consistency. SBP, PP, SV, and CO could be calculated through the regression model, but their accuracies were worse than that of transfer function model.

  17. False alarm reduction in BSN-based cardiac monitoring using signal quality and activity type information.

    PubMed

    Tanantong, Tanatorn; Nantajeewarawat, Ekawit; Thiemjarus, Surapa

    2015-02-09

    False alarms in cardiac monitoring affect the quality of medical care, impacting on both patients and healthcare providers. In continuous cardiac monitoring using wireless Body Sensor Networks (BSNs), the quality of ECG signals can be deteriorated owing to several factors, e.g., noises, low battery power, and network transmission problems, often resulting in high false alarm rates. In addition, body movements occurring from activities of daily living (ADLs) can also create false alarms. This paper presents a two-phase framework for false arrhythmia alarm reduction in continuous cardiac monitoring, using signals from an ECG sensor and a 3D accelerometer. In the first phase, classification models constructed using machine learning algorithms are used for labeling input signals. ECG signals are labeled with heartbeat types and signal quality levels, while 3D acceleration signals are labeled with ADL types. In the second phase, a rule-based expert system is used for combining classification results in order to determine whether arrhythmia alarms should be accepted or suppressed. The proposed framework was validated on datasets acquired using BSNs and the MIT-BIH arrhythmia database. For the BSN dataset, acceleration and ECG signals were collected from 10 young and 10 elderly subjects while they were performing ADLs. The framework reduced the false alarm rate from 9.58% to 1.43% in our experimental study, showing that it can potentially assist physicians in diagnosing a vast amount of data acquired from wireless sensors and enhance the performance of continuous cardiac monitoring.

  18. Bystander capability to activate speaker function for continuous dispatcher assisted CPR in case of suspected cardiac arrest.

    PubMed

    Steensberg, Alvilda T; Eriksen, Mette M; Andersen, Lars B; Hendriksen, Ole M; Larsen, Heinrich D; Laier, Gunnar H; Thougaard, Thomas

    2017-06-01

    The European Resuscitation Council Guidelines 2015 recommend bystanders to activate their mobile phone speaker function, if possible, in case of suspected cardiac arrest. This is to facilitate continuous dialogue with the dispatcher including (if required) cardiopulmonary resuscitation instructions. The aim of this study was to measure the bystander capability to activate speaker function in case of suspected cardiac arrest. In 87days, a systematic prospective registration of bystander capability to activate the speaker function, when cardiac arrest was suspected, was performed. For those asked, "can you activate your mobile phone's speaker function", audio recordings were examined and categorized into groups according to the bystanders capability to activate speaker function on their own initiative, without instructions, or with instructions from the emergency medical dispatcher. Time delay was measured, in seconds, for the bystanders without pre-activated speaker function. 42.0% (58) was able to activate the speaker function without instructions, 2.9% (4) with instructions, 18.1% (25) on own initiative and 37.0% (51) were unable to activate the speaker function. The median time to activate speaker function was 19s and 8s, with and without instructions, respectively. Dispatcher assisted cardiopulmonary resuscitation with activated speaker function, in cases of suspected cardiac arrest, allows for continuous dialogue between the emergency medical dispatcher and the bystander. In this study, we found a 63.0% success rate of activating the speaker function in such situations. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Addressing Common Questions Encountered in the Diagnosis and Management of Cardiac Amyloidosis.

    PubMed

    Maurer, Mathew S; Elliott, Perry; Comenzo, Raymond; Semigran, Marc; Rapezzi, Claudio

    2017-04-04

    Advances in cardiac imaging have resulted in greater recognition of cardiac amyloidosis in everyday clinical practice, but the diagnosis continues to be made in patients with late-stage disease, suggesting that more needs to be done to improve awareness of its clinical manifestations and the potential of therapeutic intervention to improve prognosis. Light chain cardiac amyloidosis, in particular, if recognized early and treated with targeted plasma cell therapy, can be managed very effectively. For patients with transthyretin amyloidosis, there are numerous therapies that are currently in late-phase clinical trials. In this review, we address common questions encountered in clinical practice regarding etiology, clinical presentation, diagnosis, and management of cardiac amyloidosis, focusing on recent important developments in cardiac imaging and biochemical diagnosis. The aim is to show how a systematic approach to the evaluation of suspected cardiac amyloidosis can impact the prognosis of patients in the modern era. © 2017 American Heart Association, Inc.

  20. Cardiac Autonomic Regulation and Repolarization During Acute Experimental Hypoglycemia in Type 2 Diabetes

    PubMed Central

    Chow, Elaine; Bernjak, Alan; Walkinshaw, Emma; Lubina-Solomon, Alexandra; Freeman, Jenny; Macdonald, Ian A.; Sheridan, Paul J.

    2017-01-01

    Hypoglycemia is associated with increased cardiovascular mortality in trials of intensive therapy in type 2 diabetes mellitus (T2DM). We previously observed an increase in arrhythmias during spontaneous prolonged hypoglycemia in patients with T2DM. We examined changes in cardiac autonomic function and repolarization during sustained experimental hypoglycemia. Twelve adults with T2DM and 11 age- and BMI-matched control participants without diabetes underwent paired hyperinsulinemic clamps separated by 4 weeks. Glucose was maintained at euglycemia (6.0 mmol/L) or hypoglycemia (2.5 mmol/L) for 1 h. Heart rate, blood pressure, and heart rate variability were assessed every 30 min and corrected QT intervals and T-wave morphology every 60 min. Heart rate initially increased in participants with T2DM but then fell toward baseline despite maintained hypoglycemia at 1 h accompanied by reactivation of vagal tone. In control participants, vagal tone remained depressed during sustained hypoglycemia. Participants with T2DM exhibited greater heterogeneity of repolarization during hypoglycemia as demonstrated by T-wave symmetry and principal component analysis ratio compared with control participants. Epinephrine levels during hypoglycemia were similar between groups. Cardiac autonomic regulation during hypoglycemia appears to be time dependent. Individuals with T2DM demonstrate greater repolarization abnormalities for a given hypoglycemic stimulus despite comparable sympathoadrenal responses. These mechanisms could contribute to arrhythmias during clinical hypoglycemic episodes. PMID:28137792

  1. Increased Susceptibility to Atrial Fibrillation Secondary to Atrial Fibrosis in Transgenic Goats Expressing Transforming Growth Factor-β1

    PubMed Central

    Davies, Christopher J.; Regouski, Misha; Hall, Justin; Olsen, Aaron L.; Meng, Qinggang; Rutigliano, Heloisa M.; Dosdall, Derek J.; Angel, Nathan A.; Sachse, Frank B.; Seidel, Thomas; Thomas, Aaron J.; Stott, Rusty; Panter, Kip E.; Lee, Pamela M.; Van Wettere, Arnaud J.; Stevens, John R.; Wang, Zhongde; MacLeod, Rob S.; Marrouche, Nassir F.; White, Kenneth L.

    2016-01-01

    Introduction Large animal models of progressive atrial fibrosis would provide an attractive platform to study relationship between structural and electrical remodeling in atrial fibrillation (AF). Here we established a new transgenic goat model of AF with cardiac specific overexpression of TGF-β1 and investigated the changes in the cardiac structure and function leading to AF. Methods and Results Transgenic goats with cardiac specific overexpression of constitutively active TGF-β1 were generated by somatic cell nuclear transfer. We examined myocardial tissue, ECGs, echocardiographic data, and AF susceptibility in transgenic and wild-type control goats. Transgenic goats exhibited significant increase in fibrosis and myocyte diameters in the atria compared to controls, but not in the ventricles. P-wave duration was significantly greater in transgenic animals starting at 12-month of age, but no significant chamber enlargement was detected, suggesting conduction slowing in the atria. Furthermore, this transgenic goat model exhibited a significant increase in AF vulnerability. Six of 8 transgenic goats (75%) were susceptible to AF induction and exhibited sustained AF (>2 minutes), whereas, none of 6 controls displayed sustained AF (P<0.01). Length of induced AF episodes was also significantly greater in the transgenic group compared to controls (687±212.02 vs. 2.50±0.88 seconds, P<0.0001), but no persistent or permanent AF was observed. Conclusion A novel transgenic goat model with a substrate for AF was generated. In this model, cardiac overexpression of TGF-β1 led to an increase in fibrosis and myocyte size in the atria, and to progressive P-wave prolongation. We suggest that these factors underlie increased AF susceptibility. PMID:27447370

  2. How the knowledge of genetic "makeup" and cellular data can affect the analysis of repolarization in surface electrocardiogram.

    PubMed

    Shimizu, Wataru

    2010-01-01

    This review article sought to describe patterns of repolarization on the surface electrocardiogram in inherited cardiac arrhythmias and to discuss how the knowledge of genetic makeup and cellular data can affect the analysis based on the data derived from the experimental studies using arterially perfused canine ventricular wedge preparations. Molecular genetic studies have established a link between a number of inherited cardiac arrhythmia syndromes and mutations in genes encoding cardiac ion channels or membrane components during the past 2 decades. Twelve forms of congenital long QT syndrome have been so far identified, and genotype-phenotype correlations have been investigated especially in the 3 major genotypes-LQT1, LQT2, and LQT3. Abnormal T waves are reported in the LQT1, LQT2, and LQT3, and the differences in the time course of repolarization of the epicardial, midmyocardial, and endocardial cells give rise to voltage gradients responsible for the manifestation of phenotypic appearance of abnormal T waves. Brugada syndrome is characterized by ST-segment elevation in leads V1 to V3 and an episode of ventricular fibrillation, in which 7 genotypes have been reported. An intrinsically prominent transient outward current (I(to))-mediated action potential notch and a subsequent loss of action potential dome in the epicardium, but not in the endocardium of the right ventricular outflow tract, give rise to a transmural voltage gradient, resulting in ST-segment elevation, and a subsequent phase 2 reentry-induced ventricular fibrillation. In conclusion, transmural electrical heterogeneity of repolarization across the ventricular wall profoundly affects the phenotypic manifestation of repolarization patterns on the surface electrocardiogram in inherited cardiac arrhythmias. Copyright © 2010 Elsevier Inc. All rights reserved.

  3. Mechanisms of Electrical Activation and Conduction in the Gastrointestinal System: Lessons from Cardiac Electrophysiology

    PubMed Central

    Tse, Gary; Lai, Eric Tsz Him; Yeo, Jie Ming; Tse, Vivian; Wong, Sunny Hei

    2016-01-01

    The gastrointestinal (GI) tract is an electrically excitable organ system containing multiple cell types, which coordinate electrical activity propagating through this tract. Disruption in its normal electrophysiology is observed in a number of GI motility disorders. However, this is not well characterized and the field of GI electrophysiology is much less developed compared to the cardiac field. The aim of this article is to use the established knowledge of cardiac electrophysiology to shed light on the mechanisms of electrical activation and propagation along the GI tract, and how abnormalities in these processes lead to motility disorders and suggest better treatment options based on this improved understanding. In the first part of the article, the ionic contributions to the generation of GI slow wave and the cardiac action potential (AP) are reviewed. Propagation of these electrical signals can be described by the core conductor theory in both systems. However, specifically for the GI tract, the following unique properties are observed: changes in slow wave frequency along its length, periods of quiescence, synchronization in short distances and desynchronization over long distances. These are best described by a coupled oscillator theory. Other differences include the diminished role of gap junctions in mediating this conduction in the GI tract compared to the heart. The electrophysiology of conditions such as gastroesophageal reflux disease and gastroparesis, and functional problems such as irritable bowel syndrome are discussed in detail, with reference to ion channel abnormalities and potential therapeutic targets. A deeper understanding of the molecular basis and physiological mechanisms underlying GI motility disorders will enable the development of better diagnostic and therapeutic tools and the advancement of this field. PMID:27303305

  4. Increased Susceptibility to Atrial Fibrillation Secondary to Atrial Fibrosis in Transgenic Goats Expressing Transforming Growth Factor-β1.

    PubMed

    Polejaeva, Irina A; Ranjan, Ravi; Davies, Christopher J; Regouski, Misha; Hall, Justin; Olsen, Aaron L; Meng, Qinggang; Rutigliano, Heloisa M; Dosdall, Derek J; Angel, Nathan A; Sachse, Frank B; Seidel, Thomas; Thomas, Aaron J; Stott, Rusty; Panter, Kip E; Lee, Pamela M; Van Wettere, Arnaud J; Stevens, John R; Wang, Zhongde; MacLeod, Rob S; Marrouche, Nassir F; White, Kenneth L

    2016-10-01

    Large animal models of progressive atrial fibrosis would provide an attractive platform to study relationship between structural and electrical remodeling in atrial fibrillation (AF). Here we established a new transgenic goat model of AF with cardiac specific overexpression of TGF-β1 and investigated the changes in the cardiac structure and function leading to AF. Transgenic goats with cardiac specific overexpression of constitutively active TGF-β1 were generated by somatic cell nuclear transfer. We examined myocardial tissue, ECGs, echocardiographic data, and AF susceptibility in transgenic and wild-type control goats. Transgenic goats exhibited significant increase in fibrosis and myocyte diameters in the atria compared to controls, but not in the ventricles. P-wave duration was significantly greater in transgenic animals starting at 12 months of age, but no significant chamber enlargement was detected, suggesting conduction slowing in the atria. Furthermore, this transgenic goat model exhibited a significant increase in AF vulnerability. Six of 8 transgenic goats (75%) were susceptible to AF induction and exhibited sustained AF (>2 minutes), whereas none of 6 controls displayed sustained AF (P < 0.01). Length of induced AF episodes was also significantly greater in the transgenic group compared to controls (687 ± 212.02 seconds vs. 2.50 ± 0.88 seconds, P < 0.0001), but no persistent or permanent AF was observed. A novel transgenic goat model with a substrate for AF was generated. In this model, cardiac overexpression of TGF-β1 led to an increase in fibrosis and myocyte size in the atria, and to progressive P-wave prolongation. We suggest that these factors underlie increased AF susceptibility. © 2016 Wiley Periodicals, Inc.

  5. 42 CFR § 512.700 - Basis and scope.

    Code of Federal Regulations, 2010 CFR

    2017-10-01

    ... (CONTINUED) HEALTH CARE INFRASTRUCTURE AND MODEL PROGRAMS EPISODE PAYMENT MODEL CR Incentive Payment Model... implements the cardiac rehabilitation (CR) and intensive cardiac rehabilitation (ICR) incentive payment model... in the CR incentive payment model. (2) The CR/ICR services that count toward CR incentive payments...

  6. Trigger learning and ECG parameter customization for remote cardiac clinical care information system.

    PubMed

    Bashir, Mohamed Ezzeldin A; Lee, Dong Gyu; Li, Meijing; Bae, Jang-Whan; Shon, Ho Sun; Cho, Myung Chan; Ryu, Keun Ho

    2012-07-01

    Coronary heart disease is being identified as the largest single cause of death along the world. The aim of a cardiac clinical information system is to achieve the best possible diagnosis of cardiac arrhythmias by electronic data processing. Cardiac information system that is designed to offer remote monitoring of patient who needed continues follow up is demanding. However, intra- and interpatient electrocardiogram (ECG) morphological descriptors are varying through the time as well as the computational limits pose significant challenges for practical implementations. The former requires that the classification model be adjusted continuously, and the latter requires a reduction in the number and types of ECG features, and thus, the computational burden, necessary to classify different arrhythmias. We propose the use of adaptive learning to automatically train the classifier on up-to-date ECG data, and employ adaptive feature selection to define unique feature subsets pertinent to different types of arrhythmia. Experimental results show that this hybrid technique outperforms conventional approaches and is, therefore, a promising new intelligent diagnostic tool.

  7. Wave reflections in the pulmonary arteries analysed with the reservoir–wave model

    PubMed Central

    Bouwmeester, J Christopher; Belenkie, Israel; Shrive, Nigel G; Tyberg, John V

    2014-01-01

    Conventional haemodynamic analysis of pressure and flow in the pulmonary circulation yields incident and reflected waves throughout the cardiac cycle, even during diastole. The reservoir–wave model provides an alternative haemodynamic analysis consistent with minimal wave activity during diastole. Pressure and flow in the main pulmonary artery were measured in anaesthetized dogs and the effects of hypoxia and nitric oxide, volume loading and positive end-expiratory pressure were observed. The reservoir–wave model was used to determine the reservoir contribution to pressure and flow and once subtracted, resulted in ‘excess’ quantities, which were treated as wave-related. Wave intensity analysis quantified the contributions of waves originating upstream (forward-going waves) and downstream (backward-going waves). In the pulmonary artery, negative reflections of incident waves created by the right ventricle were observed. Overall, the distance from the pulmonary artery valve to this reflection site was calculated to be 5.7 ± 0.2 cm. During 100% O2 ventilation, the strength of these reflections increased 10% with volume loading and decreased 4% with 10 cmH2O positive end-expiratory pressure. In the pulmonary arterial circulation, negative reflections arise from the junction of lobar arteries from the left and right pulmonary arteries. This mechanism serves to reduce peak systolic pressure, while increasing blood flow. PMID:24756638

  8. Emergency cardiopulmonary bypass for cardiac arrest refractory to pediatric advanced life support.

    PubMed

    Cochran, J B; Tecklenburg, F W; Lau, Y R; Habib, D M

    1999-02-01

    We report the application of emergent cardiopulmonary bypass (CPB) for three pediatric patients in the cardiac catheterization laboratory with cardiac arrest who did not respond to conventional resuscitation efforts. All three patients had return of baseline prearrest rhythms within minutes of the initiation of artificial cardiopulmonary support and the return of spontaneous circulation upon weaning CPB. Two patients had normal neurologic outcomes despite an interval of over 30 minutes from arrest to CPB. The continued judicious application and study of this technology in a small subpopulation of pediatric cardiac arrest patients is warranted.

  9. When the clock strikes: Modeling the relation between circadian rhythms and cardiac arrhythmias

    NASA Astrophysics Data System (ADS)

    Seenivasan, Pavithraa; Menon, Shakti N.; Sridhar, S.; Sinha, Sitabhra

    2016-10-01

    It has recently been observed that the occurrence of sudden cardiac death has a close statistical relationship with the time of day, viz., ventricular fibrillation is most likely to occur between 12am-6am, with 6pm-12am being the next most likely period. Consequently there has been significant interest in understanding how cardiac activity is influenced by the circadian clock, i.e., temporal oscillations in physiological activity with a period close to 24 hours and synchronized with the day-night cycle. Although studies have identified the genetic basis of circadian rhythm at the intracellular level, the mechanisms by which they influence cardiac pathologies are not yet fully understood. Evidence has suggested that diurnal variations in the conductance properties of ion channel proteins that govern the excitation dynamics of cardiac cells may provide the crucial link. In this paper, we investigate the relationship between the circadian rhythm as manifested in modulations of ion channel properties and the susceptibility to cardiac arrhythmias by using a mathematical model that describes the electrical activity in ventricular tissue. We show that changes in the channel conductance that lead to extreme values for the duration of action potentials in cardiac cells can result either in abnormally high-frequency reentrant activity or spontaneous conduction block of excitation waves. Both phenomena increase the likelihood of wavebreaks that are known to initiate potentially life- threatening arrhythmias. Thus, disruptive cardiac excitation dynamics are most likely to occur in time-intervals of the day-night cycle during which the channel properties are closest to these extreme values, providing an intriguing relation between circadian rhythms and cardiac pathologies.

  10. Genotype-Phenotype Correlation of SCN5A Mutation for the Clinical and Electrocardiographic Characteristics of Probands With Brugada Syndrome: A Japanese Multicenter Registry.

    PubMed

    Yamagata, Kenichiro; Horie, Minoru; Aiba, Takeshi; Ogawa, Satoshi; Aizawa, Yoshifusa; Ohe, Tohru; Yamagishi, Masakazu; Makita, Naomasa; Sakurada, Harumizu; Tanaka, Toshihiro; Shimizu, Akihiko; Hagiwara, Nobuhisa; Kishi, Ryoji; Nakano, Yukiko; Takagi, Masahiko; Makiyama, Takeru; Ohno, Seiko; Fukuda, Keiichi; Watanabe, Hiroshi; Morita, Hiroshi; Hayashi, Kenshi; Kusano, Kengo; Kamakura, Shiro; Yasuda, Satoshi; Ogawa, Hisao; Miyamoto, Yoshihiro; Kapplinger, Jamie D; Ackerman, Michael J; Shimizu, Wataru

    2017-06-06

    The genotype-phenotype correlation of SCN5A mutations as a predictor of cardiac events in Brugada syndrome remains controversial. We aimed to establish a registry limited to probands, with a long follow-up period, so that the genotype-phenotype correlation of SCN5A mutations in Brugada syndrome can be examined without patient selection bias. This multicenter registry enrolled 415 probands (n=403; men, 97%; age, 46±14 years) diagnosed with Brugada syndrome whose SCN5A gene was analyzed for mutations. During a mean follow-up period of 72 months, the overall cardiac event rate was 2.5%/y. In comparison with probands without mutations ( SCN5A (-), n=355), probands with SCN5A mutations ( SCN5A (+), n=60) experienced their first cardiac event at a younger age (34 versus 42 years, P =0.013), had a higher positive rate of late potentials (89% versus 73%, P =0.016), exhibited longer P-wave, PQ, and QRS durations, and had a higher rate of cardiac events ( P =0.017 by log-rank). Multivariate analysis indicated that only SCN5A mutation and history of aborted cardiac arrest were significant predictors of cardiac events ( SCN5A (+) versus SCN5A (-): hazard ratio, 2.0 and P =0.045; history of aborted cardiac arrest versus no such history: hazard ratio, 6.5 and P <0.001). Brugada syndrome patients with SCN5A mutations exhibit more conduction abnormalities on ECG and have higher risk for cardiac events. © 2017 American Heart Association, Inc.

  11. Spatiotemporal control to eliminate cardiac alternans using isostable reduction

    NASA Astrophysics Data System (ADS)

    Wilson, Dan; Moehlis, Jeff

    2017-03-01

    Cardiac alternans, an arrhythmia characterized by a beat-to-beat alternation of cardiac action potential durations, is widely believed to facilitate the transition from normal cardiac function to ventricular fibrillation and sudden cardiac death. Alternans arises due to an instability of a healthy period-1 rhythm, and most dynamical control strategies either require extensive knowledge of the cardiac system, making experimental validation difficult, or are model independent and sacrifice important information about the specific system under study. Isostable reduction provides an alternative approach, in which the response of a system to external perturbations can be used to reduce the complexity of a cardiac system, making it easier to work with from an analytical perspective while retaining many of its important features. Here, we use isostable reduction strategies to reduce the complexity of partial differential equation models of cardiac systems in order to develop energy optimal strategies for the elimination of alternans. Resulting control strategies require significantly less energy to terminate alternans than comparable strategies and do not require continuous state feedback.

  12. Cardiac Progenitor Cells and Bone Marrow-Derived Very Small Embryonic-Like Stem Cells for Cardiac Repair After Myocardial Infarction

    PubMed Central

    Tang, Xian-Liang; Rokosh, D. Gregg; Guo, Yiru; Bolli, Roberto

    2010-01-01

    Heart failure after myocardial infarction (MI) continues to be the most prevalent cause of morbidity and mortality worldwide. Although pharmaceutical agents and interventional strategies have contributed greatly to therapy, new and superior treatment modalities are urgently needed given the overall disease burden. Stem cell-based therapy is potentially a promising strategy to lead to cardiac repair after MI. An array of cell types has been explored in this respect, including skeletal myoblasts, bone marrow (BM)-derived stem cells, embryonic stem cells, and more recently, cardiac progenitor cells (CPCs). Recently studies have obtained evidence that transplantation of CPCs or BM-derived very small embryonic-like stem cells can improve cardiac function and alleviate cardiac remodeling, supporting the potential therapeutic utility of these cells for cardiac repair. This report summarizes the current data from those studies and discusses the potential implication of these cells in developing clinically-relevant stem cell-based therapeutic strategies for cardiac regeneration. PMID:20081317

  13. On the Design of an Efficient Cardiac Health Monitoring System Through Combined Analysis of ECG and SCG Signals.

    PubMed

    Sahoo, Prasan Kumar; Thakkar, Hiren Kumar; Lin, Wen-Yen; Chang, Po-Cheng; Lee, Ming-Yih

    2018-01-28

    Cardiovascular disease (CVD) is a major public concern and socioeconomic problem across the globe. The popular high-end cardiac health monitoring systems such as magnetic resonance imaging (MRI), computerized tomography scan (CT scan), and echocardiography (Echo) are highly expensive and do not support long-term continuous monitoring of patients without disrupting their activities of daily living (ADL). In this paper, the continuous and non-invasive cardiac health monitoring using unobtrusive sensors is explored aiming to provide a feasible and low-cost alternative to foresee possible cardiac anomalies in an early stage. It is learned that cardiac health monitoring based on sole usage of electrocardiogram (ECG) signals may not provide powerful insights as ECG provides shallow information on various cardiac activities in the form of electrical impulses only. Hence, a novel low-cost, non-invasive seismocardiogram (SCG) signal along with ECG signals are jointly investigated for the robust cardiac health monitoring. For this purpose, the in-laboratory data collection model is designed for simultaneous acquisition of ECG and SCG signals followed by mechanisms for the automatic delineation of relevant feature points in acquired ECG and SCG signals. In addition, separate feature points based novel approach is adopted to distinguish between normal and abnormal morphology in each ECG and SCG cardiac cycle. Finally, a combined analysis of ECG and SCG is carried out by designing a Naïve Bayes conditional probability model. Experiments on Institutional Review Board (IRB) approved licensed ECG/SCG signals acquired from real subjects containing 12,000 cardiac cycles show that the proposed feature point delineation mechanisms and abnormal morphology detection methods consistently perform well and give promising results. In addition, experimental results show that the combined analysis of ECG and SCG signals provide more reliable cardiac health monitoring compared to the standalone use of ECG and SCG.

  14. On the Design of an Efficient Cardiac Health Monitoring System Through Combined Analysis of ECG and SCG Signals

    PubMed Central

    Lin, Wen-Yen; Chang, Po-Cheng

    2018-01-01

    Cardiovascular disease (CVD) is a major public concern and socioeconomic problem across the globe. The popular high-end cardiac health monitoring systems such as magnetic resonance imaging (MRI), computerized tomography scan (CT scan), and echocardiography (Echo) are highly expensive and do not support long-term continuous monitoring of patients without disrupting their activities of daily living (ADL). In this paper, the continuous and non-invasive cardiac health monitoring using unobtrusive sensors is explored aiming to provide a feasible and low-cost alternative to foresee possible cardiac anomalies in an early stage. It is learned that cardiac health monitoring based on sole usage of electrocardiogram (ECG) signals may not provide powerful insights as ECG provides shallow information on various cardiac activities in the form of electrical impulses only. Hence, a novel low-cost, non-invasive seismocardiogram (SCG) signal along with ECG signals are jointly investigated for the robust cardiac health monitoring. For this purpose, the in-laboratory data collection model is designed for simultaneous acquisition of ECG and SCG signals followed by mechanisms for the automatic delineation of relevant feature points in acquired ECG and SCG signals. In addition, separate feature points based novel approach is adopted to distinguish between normal and abnormal morphology in each ECG and SCG cardiac cycle. Finally, a combined analysis of ECG and SCG is carried out by designing a Naïve Bayes conditional probability model. Experiments on Institutional Review Board (IRB) approved licensed ECG/SCG signals acquired from real subjects containing 12,000 cardiac cycles show that the proposed feature point delineation mechanisms and abnormal morphology detection methods consistently perform well and give promising results. In addition, experimental results show that the combined analysis of ECG and SCG signals provide more reliable cardiac health monitoring compared to the standalone use of ECG and SCG. PMID:29382098

  15. Predictive Modeling of Cardiac Ischemia

    NASA Technical Reports Server (NTRS)

    Anderson, Gary T.

    1996-01-01

    The goal of the Contextual Alarms Management System (CALMS) project is to develop sophisticated models to predict the onset of clinical cardiac ischemia before it occurs. The system will continuously monitor cardiac patients and set off an alarm when they appear about to suffer an ischemic episode. The models take as inputs information from patient history and combine it with continuously updated information extracted from blood pressure, oxygen saturation and ECG lines. Expert system, statistical, neural network and rough set methodologies are then used to forecast the onset of clinical ischemia before it transpires, thus allowing early intervention aimed at preventing morbid complications from occurring. The models will differ from previous attempts by including combinations of continuous and discrete inputs. A commercial medical instrumentation and software company has invested funds in the project with a goal of commercialization of the technology. The end product will be a system that analyzes physiologic parameters and produces an alarm when myocardial ischemia is present. If proven feasible, a CALMS-based system will be added to existing heart monitoring hardware.

  16. E-wave generated intraventricular diastolic vortex to L-wave relation: model-based prediction with in vivo validation.

    PubMed

    Ghosh, Erina; Caruthers, Shelton D; Kovács, Sándor J

    2014-08-01

    The Doppler echocardiographic E-wave is generated when the left ventricle's suction pump attribute initiates transmitral flow. In some subjects E-waves are accompanied by L-waves, the occurrence of which has been correlated with diastolic dysfunction. The mechanisms for L-wave generation have not been fully elucidated. We propose that the recirculating diastolic intraventricular vortex ring generates L-waves and based on this mechanism, we predict the presence of L-waves in the right ventricle (RV). We imaged intraventricular flow using Doppler echocardiography and phase-contrast magnetic resonance imaging (PC-MRI) in 10 healthy volunteers. L-waves were recorded in all subjects, with highest velocities measured typically 2 cm below the annulus. Fifty-five percent of cardiac cycles (189 of 345) had L-waves. Color M-mode images eliminated mid-diastolic transmitral flow as the cause of the observed L-waves. Three-dimensional intraventricular flow patterns were imaged via PC-MRI and independently validated our hypothesis. Additionally as predicted, L-waves were observed in the RV, by both echocardiography and PC-MRI. The re-entry of the E-wave-generated vortex ring flow through a suitably located echo sample volume can be imaged as the L-wave. These waves are a general feature and a direct consequence of LV and RV diastolic fluid mechanics. Copyright © 2014 the American Physiological Society.

  17. Mechanical perturbation control of cardiac alternans

    NASA Astrophysics Data System (ADS)

    Hazim, Azzam; Belhamadia, Youssef; Dubljevic, Stevan

    2018-05-01

    Cardiac alternans is a disturbance in heart rhythm that is linked to the onset of lethal cardiac arrhythmias. Mechanical perturbation control has been recently used to suppress alternans in cardiac tissue of relevant size. In this control strategy, cardiac tissue mechanics are perturbed via active tension generated by the heart's electrical activity, which alters the tissue's electric wave profile through mechanoelectric coupling. We analyze the effects of mechanical perturbation on the dynamics of a map model that couples the membrane voltage and active tension systems at the cellular level. Therefore, a two-dimensional iterative map of the heart beat-to-beat dynamics is introduced, and a stability analysis of the system of coupled maps is performed in the presence of a mechanical perturbation algorithm. To this end, a bidirectional coupling between the membrane voltage and active tension systems in a single cardiac cell is provided, and a discrete form of the proposed control algorithm, that can be incorporated in the coupled maps, is derived. In addition, a realistic electromechanical model of cardiac tissue is employed to explore the feasibility of suppressing alternans at cellular and tissue levels. Electrical activity is represented in two detailed ionic models, the Luo-Rudy 1 and the Fox models, while two active contractile tension models, namely a smooth variant of the Nash-Panfilov model and the Niederer-Hunter-Smith model, are used to represent mechanical activity in the heart. The Mooney-Rivlin passive elasticity model is employed to describe passive mechanical behavior of the myocardium.

  18. Effects of bilastine on T-wave morphology and the QTc interval: a randomized, double-blind, placebo-controlled, thorough QTc study.

    PubMed

    Graff, Claus; Struijk, Johannes J; Kanters, Jørgen K; Andersen, Mads P; Toft, Egon; Tyl, Benoît

    2012-05-01

    The International Conference of Harmonisation (ICH) E14 guideline for thorough QT studies requires assessing the propensity of new non-antiarrhythmic drugs to affect cardiac repolarization. The present study investigates whether a composite ECG measure of T-wave morphology (Morphology Combination Score [MCS]) can be used together with the heart rate corrected QT interval (QTc) in a fully ICH E14-compliant thorough QT study to exclude clinically relevant repolarization effects of bilastine, a novel antihistamine. Thirty participants in this crossover study were randomly assigned to receive placebo, moxifloxacin 400 mg, bilastine at therapeutic and supratherapeutic doses (20 and 100 mg) and bilastine 20 mg co-administered with ketoconazole 400 mg. Resting ECGs recorded at 12 nominal time points before and after treatments were used to determine Fridericia corrected QTc (QTcF) and MCS from the T-wave characteristics: asymmetry, flatness and notching. There were no effects of bilastine monotherapy (20 and 100 mg) on MCS or QTcF at those study times where the bilastine plasma concentrations were highest. MCS changes for bilastine monotherapy did not exceed the normal intrasubject variance of T-wave shapes for triplicate ECG recordings. Maximum QTcF prolongation for bilastine monotherapy was 5 ms or less: 3.8 ms (90% CI 0.3, 7.3 ms) for bilastine 20 mg and 5.0 ms (90% CI 2.0, 8.0 ms) for bilastine 100 mg. There were no indications of bilastine inducing larger repolarization effects on T-wave morphology as compared with the QTcF interval, as evidenced by the similarity of z-score equivalents for placebo-corrected changes in MCS and QTcF values. This study shows that bilastine, at therapeutic and supratherapeutic dosages, does not induce any effects on T-wave morphology or QTcF. These results confirm the absence of an effect for bilastine on cardiac repolarization.

  19. Patterns of heterotypic continuity associated with the cross-sectional correlational structure of prevalent mental disorders in adults.

    PubMed

    Lahey, Benjamin B; Zald, David H; Hakes, Jahn K; Krueger, Robert F; Rathouz, Paul J

    2014-09-01

    Mental disorders predict future occurrences of both the same disorder (homotypic continuity) and other disorders (heterotypic continuity). Heterotypic continuity is inconsistent with a view of mental disorders as fixed entities. In contrast, hierarchical-dimensional conceptualizations of psychopathology, in which each form of psychopathology is hypothesized to have both unique and broadly shared etiologies and mechanisms, predict both homotypic and heterotypic continuity. To test predictions derived from a hierarchical-dimensional model of psychopathology that (1) heterotypic continuity is widespread, even controlling for homotypic continuity, and that (2) the relative magnitudes of heterotypic continuities recapitulate the relative magnitudes of cross-sectional correlations among diagnoses at baseline. Ten prevalent diagnoses were assessed in the same person twice (ie, in 2 waves separated by 3 years). We used a representative sample of adults in the United States (i.e., 28,958 participants 18-64 years of age in the National Epidemiologic Study of Alcohol and Related Conditions who were assessed in both waves). Diagnoses from reliable and valid structured interviews. Adjusting for sex and age, we found that bivariate associations of all pairs of diagnoses from wave 1 to wave 2 exceeded chance levels (P < .05) for all homotypic (median tetrachoric correlation of ρ = 0.54 [range, 0.41-0.79]) and for nearly all heterotypic continuities (median tetrachoric correlation of ρ = 0.28 [range, 0.07-0.50]). Significant heterotypic continuity was widespread even when all wave 1 diagnoses (including the same diagnosis) were simultaneous predictors of each wave 2 diagnosis. The rank correlation between age- and sex-adjusted tetrachoric correlation for cross-sectional associations among wave 1 diagnoses and for heterotypic associations from wave 1 to wave 2 diagnoses was ρ = 0.86 (P < .001). For these prevalent mental disorders, heterotypic continuity was nearly universal and not an artifact of failure to control for homotypic continuity. Furthermore, the relative magnitudes of heterotypic continuity closely mirrored the relative magnitudes of cross-sectional associations among these disorders, consistent with the hypothesis that both sets of associations reflect the same factors. Mental disorders are not fixed and independent entities. Rather, each diagnosis is robustly related to other diagnoses in a correlational structure that is manifested both concurrently and in patterns of heterotypic continuity across time.

  20. Continuous-wave terahertz imaging of nonmelanoma skin cancers

    NASA Astrophysics Data System (ADS)

    Joseph, Cecil Sudhir

    Continuous wave terahertz imaging has the potential to offer a safe, non-invasive medical imaging modality for detecting different types of human skin cancers. Terahertz pulse imaging (TPI) has already shown that there is contrast between basal cell carcinoma and normal skin. Continuous-wave imaging offers a simpler, lower cost alternative to terahertz pulse imaging. This project aims to isolate the optimal contrast frequency for a continuous wave terahertz imaging system and demonstrate transmission based, in-vitro , imaging of thin sections of non-melanoma skin cancers and correlate the images to sample histology. The aim of this project is to conduct a proof-of-principle experiment that establishes whether continuous-wave terahertz imaging can detect differences between cancerous and normal tissue while outlining the basic requirements for building a system capable of performing in vivo tests.

  1. [Third phase of cardiac rehabilitation: a nurse-based "home-control" model].

    PubMed

    Albertini, Sara; Ciocca, Antonella; Opasich, Cristina; Pinna, Gian Domenico; Cobelli, Franco

    2011-12-01

    Phase 3 is a critical point for cardiac rehabilitation: many problems don't allow achieving a correct secondary prevention, in particular regarding the relationship between patient and cardiologist. Aiming at ensuring continuity of care of phase 3 cardiac rehabilitation patients, we have developed a telemetric educational program to stimulate in them the will and capacity to become active comanagers of their disease. Nurses specialized in cardiac rehabilitation, with the collaboration of the general practitioners, contact the patients by scheduled phone calls to collect questionnaires about their health status and the result of biochemistry. All the results are analyzed by the nurses and discussed with each patient (educational reinforcement). The effects of this program of comanagement of cardiac disease and secondary prevention are analyzed comparing each patient data at the discharge with data after one year and those coming from our archive (retrospective analysis). The patients enrolled in this study pay much more attention to the amount of food they eat; they tend not to gain weight, and they restart smoking in a reduced proportion compared to patients not enrolled in the study. However, despite having received better information on their cardiac disease, their compliance to physical training, consumption of healthy food, and pharmacological therapy is not improved. This study focuses on the role of a continuous educational program of a cardiac rehabilitation unit after the patient's discharge. This home control program conducted by nurses specialized in cardiac rehabilitation, with the assistance of cardiologists, psychologists and physiotherapists, and in collaboration with the general practitioner, was quite cheap, and helped maximizing the knowledge of the disease and reinforcing correct life style in the patients. The results are not as good as expected, probably because one year does not represent a sufficient time, or because the educational intervention needs to be improved.

  2. Electrocardiographic Characteristics of Potential Organ Donors and Associations with Cardiac Allograft Utilization

    PubMed Central

    Khush, Kiran K.; Menza, Rebecca; Nguyen, John; Goldstein, Benjamin A.; Zaroff, Jonathan G.; Drew, Barbara J.

    2012-01-01

    Background Current regulations require that all cardiac allograft offers for transplantation must include an interpreted 12-lead electrocardiogram (ECG). However, little is known about the expected ECG findings in potential organ donors, or the clinical significance of any identified abnormalities in terms of cardiac allograft function and suitability for transplantation. Methods and Results A single experienced reviewer interpreted the first ECG obtained after brainstem herniation in 980 potential organ donors managed by the California Transplant Donor Network from 2002-2007. ECG abnormalities were summarized, and associations between specific ECG findings and cardiac allograft utilization for transplantation were studied. ECG abnormalities were present in 51% of all cases reviewed. The most common abnormalities included voltage criteria for left ventricular hypertrophy (LVH), prolongation of the corrected QT interval (QTc), and repolarization changes (ST/T wave abnormalities). Fifty seven percent of potential cardiac allografts in this cohort were accepted for transplantation. LVH on ECG was a strong predictor of allograft non-utilization. No significant associations were seen between QTc prolongation, repolarization changes and allograft utilization for transplantation, after adjusting for donor clinical variables and echocardiographic findings. Conclusions We have performed the first comprehensive study of ECG findings in potential donors for cardiac transplantation. Many of the common ECG abnormalities seen in organ donors may result from the heightened state of sympathetic activation that occurs after brainstem herniation, and are not associated with allograft utilization for transplantation. PMID:22615333

  3. Murine fetal echocardiography.

    PubMed

    Kim, Gene H

    2013-02-15

    Transgenic mice displaying abnormalities in cardiac development and function represent a powerful tool for the understanding the molecular mechanisms underlying both normal cardiovascular function and the pathophysiological basis of human cardiovascular disease. Fetal and perinatal death is a common feature when studying genetic alterations affecting cardiac development. In order to study the role of genetic or pharmacologic alterations in the early development of cardiac function, ultrasound imaging of the live fetus has become an important tool for early recognition of abnormalities and longitudinal follow-up. Noninvasive ultrasound imaging is an ideal method for detecting and studying congenital malformations and the impact on cardiac function prior to death. It allows early recognition of abnormalities in the living fetus and the progression of disease can be followed in utero with longitudinal studies. Until recently, imaging of fetal mouse hearts frequently involved invasive methods. The fetus had to be sacrificed to perform magnetic resonance microscopy and electron microscopy or surgically delivered for transillumination microscopy. An application of high-frequency probes with conventional 2-D and pulsed-wave Doppler imaging has been shown to provide measurements of cardiac contraction and heart rates during embryonic development with databases of normal developmental changes now available. M-mode imaging further provides important functional data, although, the proper imaging planes are often difficult to obtain. High-frequency ultrasound imaging of the fetus has improved 2-D resolution and can provide excellent information on the early development of cardiac structures.

  4. Quasiperiodicity and chaos in cardiac fibrillation.

    PubMed Central

    Garfinkel, A; Chen, P S; Walter, D O; Karagueuzian, H S; Kogan, B; Evans, S J; Karpoukhin, M; Hwang, C; Uchida, T; Gotoh, M; Nwasokwa, O; Sager, P; Weiss, J N

    1997-01-01

    In cardiac fibrillation, disorganized waves of electrical activity meander through the heart, and coherent contractile function is lost. We studied fibrillation in three stationary forms: in human chronic atrial fibrillation, in a stabilized form of canine ventricular fibrillation, and in fibrillation-like activity in thin sheets of canine and human ventricular tissue in vitro. We also created a computer model of fibrillation. In all four studies, evidence indicated that fibrillation arose through a quasiperiodic stage of period and amplitude modulation, thus exemplifying the "quasiperiodic transition to chaos" first suggested by Ruelle and Takens. This suggests that fibrillation is a form of spatio-temporal chaos, a finding that implies new therapeutic approaches. PMID:9005999

  5. Quasiperiodicity and chaos in cardiac fibrillation.

    PubMed

    Garfinkel, A; Chen, P S; Walter, D O; Karagueuzian, H S; Kogan, B; Evans, S J; Karpoukhin, M; Hwang, C; Uchida, T; Gotoh, M; Nwasokwa, O; Sager, P; Weiss, J N

    1997-01-15

    In cardiac fibrillation, disorganized waves of electrical activity meander through the heart, and coherent contractile function is lost. We studied fibrillation in three stationary forms: in human chronic atrial fibrillation, in a stabilized form of canine ventricular fibrillation, and in fibrillation-like activity in thin sheets of canine and human ventricular tissue in vitro. We also created a computer model of fibrillation. In all four studies, evidence indicated that fibrillation arose through a quasiperiodic stage of period and amplitude modulation, thus exemplifying the "quasiperiodic transition to chaos" first suggested by Ruelle and Takens. This suggests that fibrillation is a form of spatio-temporal chaos, a finding that implies new therapeutic approaches.

  6. Incremental value of contrast echocardiography in the evaluation of a cardiac thrombus.

    PubMed

    Po, Jose Ricardo F; Tong, Matthew S; Grove, Erica L; Biederman, Robert W W

    2017-02-01

    A 52-year-old man presented with altered mental status and report of prior complaint of chest pain. On electrocardiography, anterolateral ST-segment elevations with Q-waves in the septal leads were seen. Initial echocardiography images demonstrated a thickened anteroseptum. Further imaging showed the presence of a well-attached laminated apical thrombus. Contrast echocardiography images showed that the thrombus had minimal attachment to the endocardial surface. CT head subsequently showed the presence of acute stroke. The case demonstrates the additional value of contrast echocardiography in the evaluation of cardiac masses despite the certainty in the diagnosis of a thrombus. © 2017, Wiley Periodicals, Inc.

  7. ECG Monitoring in Cardiac Rehabilitation: Is It Needed?

    ERIC Educational Resources Information Center

    Greenland, Philip; Pomilla, Paul V.

    1989-01-01

    Discusses the controversial use of continuous electrocardiogram (ECG) monitoring as a safety measure in cardiac rehabilitation exercise programs. Little evidence substantiates its value for all patients during exercise. In the absence of empirical evidence documenting the worth of this expensive procedure, it is recommended for use with high-risk…

  8. Mianserin, maprotiline and intracardiac conduction

    PubMed Central

    Edwards, J. Guy; Goldie, Ann

    1983-01-01

    1 High speed surface electrocardiograms were recorded in 35 patients during the baseline and after four weeks' treatment in a placebo-controlled trial of mianserin and maprotiline in primary depressive illness. 2 Measurements of the RR, PR and QT intervals, QRS width and T wave height were made blind to patient, drug and treatment interval and compared with plasma drug concentrations. The presence or absence of cardiac arrhythmias was recorded. 3 The only significant findings were an increased heart rate and PR interval and decreased QTc interval in the maprotiline group. Only one patient receiving maprotiline had a cardiac arrhythmia. There was no significant correlation between measurements of ECG parameters and plasma drug levels. 4 The results confirm the lack of cardiac effects of mianserin and show both anticholinergic activity and effects of an intracardiac conduction in the case of maprotiline. The mechanisms of these effects are discussed. PMID:6824556

  9. Towards an atrio-ventricular delay optimization assessed by a computer model for cardiac resynchronization therapy

    NASA Astrophysics Data System (ADS)

    Ojeda, David; Le Rolle, Virginie; Tse Ve Koon, Kevin; Thebault, Christophe; Donal, Erwan; Hernández, Alfredo I.

    2013-11-01

    In this paper, lumped-parameter models of the cardiovascular system, the cardiac electrical conduction system and a pacemaker are coupled to generate mitral ow pro les for di erent atrio-ventricular delay (AVD) con gurations, in the context of cardiac resynchronization therapy (CRT). First, we perform a local sensitivity analysis of left ventricular and left atrial parameters on mitral ow characteristics, namely E and A wave amplitude, mitral ow duration, and mitral ow time integral. Additionally, a global sensitivity analysis over all model parameters is presented to screen for the most relevant parameters that a ect the same mitral ow characteristics. Results provide insight on the in uence of left ventricle and atrium in uence on mitral ow pro les. This information will be useful for future parameter estimation of the model that could reproduce the mitral ow pro les and cardiovascular hemodynamics of patients undergoing AVD optimization during CRT.

  10. The heart-break of social rejection versus the brain wave of social acceptance

    PubMed Central

    van der Molen, Maurits W.; Sahibdin, Priya P.; Franken, Ingmar H. A.

    2014-01-01

    The effect of social rejection on cardiac and brain responses was examined in a study in which participants had to decide on the basis of pictures of virtual peers whether these peers would like them or not. Physiological and behavioral responses to expected and unexpected acceptance and rejection were compared. It was found that participants expected that about 50% of the virtual judges gave them a positive judgment. Cardiac deceleration was strongest for unexpected social rejection. In contrast, the brain response was strongest to expected acceptance and was characterized by a positive deflection peaking around 325 ms following stimulus onset and the observed difference was maximal at fronto-central positions. The cardiac and electro-cortical responses were not related. It is hypothesized that these differential response patterns might be related to earlier described differential involvement of the dorsal and ventral portion of the anterior cingulate cortex. PMID:23887821

  11. Non-conforming finite-element formulation for cardiac electrophysiology: an effective approach to reduce the computation time of heart simulations without compromising accuracy

    NASA Astrophysics Data System (ADS)

    Hurtado, Daniel E.; Rojas, Guillermo

    2018-04-01

    Computer simulations constitute a powerful tool for studying the electrical activity of the human heart, but computational effort remains prohibitively high. In order to recover accurate conduction velocities and wavefront shapes, the mesh size in linear element (Q1) formulations cannot exceed 0.1 mm. Here we propose a novel non-conforming finite-element formulation for the non-linear cardiac electrophysiology problem that results in accurate wavefront shapes and lower mesh-dependance in the conduction velocity, while retaining the same number of global degrees of freedom as Q1 formulations. As a result, coarser discretizations of cardiac domains can be employed in simulations without significant loss of accuracy, thus reducing the overall computational effort. We demonstrate the applicability of our formulation in biventricular simulations using a coarse mesh size of ˜ 1 mm, and show that the activation wave pattern closely follows that obtained in fine-mesh simulations at a fraction of the computation time, thus improving the accuracy-efficiency trade-off of cardiac simulations.

  12. Tripolar Laplacian electrocardiogram and moment of activation isochronal mapping.

    PubMed

    Besio, W; Chen, T

    2007-05-01

    The electrocardiogram (ECG) provides useful global temporal assessment of the cardiac activity, but has limited spatial capabilities. The Laplacian electrocardiogram (LECG), an improvement over the ECG, provides high spatiotemporal distributed information about cardiac electrical activation. We designed and developed LECG tripolar concentric ring electrode active sensors based on the finite element algorithm 'nine-point method' (NPM). The active sensors were used in an array of 6 by 12 (72) locations to record bipolar and tripolar LECG from the body surface over the anterolateral chest. Compared to bipolar LECG, tripolar LECG showed significantly higher spatial selectivity which may be helpful in inferring information about cardiac activations detected on the body surface. In this study the moment of activation (MOA), an indicator of a depolarization wave passing below the active sensors, was used to surmise possible timing information of the cardiac electrical activation below the active sensors' recording sites. The MOA on the body surface was used to generate isochronal maps that may some day be used by clinicians in diagnosing arrhythmias and assessing the efficacy of therapies.

  13. Person identification in irregular cardiac conditions using electrocardiogram signals.

    PubMed

    Sidek, Khairul Azami; Khalil, Ibrahim

    2011-01-01

    This paper presents a person identification mechanism in irregular cardiac conditions using ECG signals. A total of 30 subjects were used in the study from three different public ECG databases containing various abnormal heart conditions from the Paroxysmal Atrial Fibrillation Predicition Challenge database (AFPDB), MIT-BIH Supraventricular Arrthymia database (SVDB) and T-Wave Alternans Challenge database (TWADB). Cross correlation (CC) was used as the biometric matching algorithm with defined threshold values to evaluate the performance. In order to measure the efficiency of this simple yet effective matching algorithm, two biometric performance metrics were used which are false acceptance rate (FAR) and false reject rate (FRR). Our experimentation results suggest that ECG based biometric identification with irregular cardiac condition gives a higher recognition rate of different ECG signals when tested for three different abnormal cardiac databases yielding false acceptance rate (FAR) of 2%, 3% and 2% and false reject rate (FRR) of 1%, 2% and 0% for AFPDB, SVDB and TWADB respectively. These results also indicate the existence of salient biometric characteristics in the ECG morphology within the QRS complex that tends to differentiate individuals.

  14. Continuous Positive Airway Pressure Versus Oxygen Therapy in the Cardiac Surgical Ward: A Randomized Trial.

    PubMed

    Olper, Luigi; Bignami, Elena; Di Prima, Ambra L; Albini, Santina; Nascimbene, Simona; Cabrini, Luca; Landoni, Giovanni; Alfieri, Ottavio

    2017-02-01

    Noninvasive ventilation (NIV) is a common technique to manage patients with acute respiratory failure in the intensive care unit. However, use of NIV in general wards is less well described. The authors' aim was to demonstrate efficacy of NIV, applied in a cardiac surgery ward, in improving oxygenation in patients who developed hypoxemic acute respiratory failure after being discharged from the intensive care unit. Randomized, open-label trial. University hospital. Sixty-four patients with hypoxemia (PaO 2 /F I O 2 ratio between 100 and 250) admitted to the main ward after cardiac surgery. Patients were randomized to receive standard treatment (oxygen, early mobilization, a program of breathing exercises and diuretics) or continuous positive airway pressure in addition to standard treatment. Continuous positive airway pressure was administered 3 times a day for 2 consecutive days. Every cycle lasted 1 to 3 hours. All patients completed their 1-year follow-up. Data were analyzed according to the intention-to-treat principle. The primary endpoint was the number of patients with PaO 2 /F I O 2 <200 48 hours after randomization. Continuous positive airway pressure use was associated with a statistically significant reduction in the number of patients with PaO 2 /F I O 2 <200 (4/33 [12%] v 14/31 [45%], p = 0.003). One patient in the control group died at the 30-day follow-up. Among patients with acute respiratory failure following cardiac surgery, administration of continuous positive airway pressure in the main ward was associated with improved respiratory outcome. This was the first study that was performed in the main ward of post-surgical patients with acute respiratory failure. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Comparison of an Oscillometric Method with Cardiac Magnetic Resonance for the Analysis of Aortic Pulse Wave Velocity

    PubMed Central

    Feistritzer, Hans-Josef; Reinstadler, Sebastian J.; Klug, Gert; Kremser, Christian; Seidner, Benjamin; Esterhammer, Regina; Schocke, Michael F.; Franz, Wolfgang-Michael; Metzler, Bernhard

    2015-01-01

    Objectives Pulse wave velocity (PWV) is the proposed gold-standard for the assessment of aortic elastic properties. The aim of this study was to compare aortic PWV determined by a recently developed oscillometric device with cardiac magnetic resonance imaging (CMR). Methods PWV was assessed in 40 volunteers with two different methods. The oscillometric method (PWVOSC) is based on a transfer function from the brachial pressure waves determined by oscillometric blood pressure measurements with a common cuff (Mobil-O-Graph, I.E.M. Stolberg, Germany). CMR was used to determine aortic PWVCMR with the use of the transit time method based on phase-contrast imaging at the level of the ascending and abdominal aorta on a clinical 1.5 Tesla scanner (Siemens, Erlangen, Germany). Results The median age of the study population was 34 years (IQR: 24–55 years, 11 females). A very strong correlation was found between PWVOSC and PWVCMR (r = 0.859, p < 0.001). Mean PWVOSC was 6.7 ± 1.8 m/s and mean PWVCMR was 6.1 ± 1.8 m/s (p < 0.001). Analysis of agreement between the two measurements using Bland-Altman method showed a bias of 0.57 m/s (upper and lower limit of agreement: 2.49 m/s and -1.34 m/s). The corresponding coefficient of variation between both measurements was 15%. Conclusion Aortic pulse wave velocity assessed by transformation of the brachial pressure waveform showed an acceptable agreement with the CMR-derived transit time method. PMID:25612307

  16. Fresh gasoline emissions, not paved road dust, alter cardiac repolarization in ApoE-/- mice.

    PubMed

    Campen, Matthew J; McDonald, Jacob D; Reed, Matthew D; Seagrave, Jeanclare

    2006-01-01

    Fresh vehicular emissions potentially represent a ubiquitous environmental concern for cardiovascular health. We compared electrocardiographic effects of fresh gasoline engine emissions with resuspended paved road dust in a mouse model of coronary insufficiency. Apolipoprotein E (ApoE)-/- mice on a high fat diet were exposed by whole-body inhalation to either gasoline emissions at 60 microg/m3 particulate matter (PM), an equivalent atmosphere with particles filtered out of the whole exhaust, or paved road dust at 0.5 and 3.5 mg /m3 for 6 h/d for 3 d. Radiotelemetry recordings of electrocardiogram (ECG) were analyzed for changes in T-wave morphology (QT interval, T-wave amplitude, and T-wave Area). Following exposures, lung lavage and blood samples were obtained to assay for markers of pulmonary and systemic inflammation. No exposure induced significant changes in heart rate and only the high concentration of road dust induced signs of pulmonary inflammation. T-wave area exhibited significant deviation from baseline values during exposure to gasoline exhaust particulates, but not to either concentration of road dust or gasoline emissions sans particulates. Gasoline-exposed mice demonstrated elevated plasma endothelin-1, but did not cause systemic inflammation. These data support the hypothesis that freshly-generated engine emissions, as opposed to resuspended paved road dust, may drive cardiac effects that have been observed at road-sides in the environment. The absence of ECG effects for both very high concentrations of road dust PM and equivalent concentrations of the vapor/gas phase of gasoline engine exhaust further indicate the specific risk conferred by fresh vehicular PM.

  17. Importance of leptin signaling and signal transducer and activator of transcription-3 activation in mediating the cardiac hypertrophy associated with obesity.

    PubMed

    Leifheit-Nestler, Maren; Wagner, Nana-Maria; Gogiraju, Rajinikanth; Didié, Michael; Konstantinides, Stavros; Hasenfuss, Gerd; Schäfer, Katrin

    2013-07-11

    The adipokine leptin and its receptor are expressed in the heart, and leptin has been shown to promote cardiomyocyte hypertrophy in vitro. Obesity is associated with hyperleptinemia and hypothalamic leptin resistance as well as an increased risk to develop cardiac hypertrophy and heart failure. However, the role of cardiac leptin signaling in mediating the cardiomyopathy associated with increased body weight is unclear, in particular, whether it develops subsequently to cardiac leptin resistance or overactivation of hypertrophic signaling pathways via elevated leptin levels. The cardiac phenotype of high-fat diet (HFD)-induced obese wildtype (WT) mice was examined and compared to age-matched genetically obese leptin receptor (LepR)-deficient (LepRdb/db) or lean WT mice. To study the role of leptin-mediated STAT3 activation during obesity-induced cardiac remodeling, mice in which tyrosine residue 1138 within LepR had been replaced with a serine (LepRS1138) were also analyzed. Obesity was associated with hyperleptinemia and elevated cardiac leptin expression in both diet-induced and genetically obese mice. Enhanced LepR and STAT3 phosphorylation levels were detected in hearts of obese WT mice, but not in those with LepR mutations. Moreover, exogenous leptin continued to induce cardiac STAT3 activation in diet-induced obese mice. Although echocardiography revealed signs of cardiac hypertrophy in all obese mice, the increase in left ventricular (LV) mass and diameter was significantly more pronounced in LepRS1138 animals. LepRS1138 mice also exhibited an increased activation of signaling proteins downstream of LepR, including Jak2 (1.8-fold), Src kinase (1.7-fold), protein kinase B (1.3-fold) or C (1.6-fold). Histological analysis of hearts revealed that the inability of leptin to activate STAT3 in LepRdb/db and LepRS1138 mice was associated with reduced cardiac angiogenesis as well as increased apoptosis and fibrosis. Our findings suggest that hearts from obese mice continue to respond to elevated circulating or cardiac leptin, which may mediate cardioprotection via LepR-induced STAT3 activation, whereas signals distinct from LepR-Tyr1138 promote cardiac hypertrophy. On the other hand, the presence of cardiac hypertrophy in obese mice with complete LepR signal disruption indicates that additional pathways also play a role.

  18. Cardiac Patients’ Walking Activity Determined by a Step Counter in Cardiac Telerehabilitation: Data From the Intervention Arm of a Randomized Controlled Trial

    PubMed Central

    Hansen, John; Grønkjær, Mette; Andreasen, Jan Jesper; Nielsen, Gitte; Sørensen, Erik Elgaard; Dinesen, Birthe Irene

    2016-01-01

    Background Walking represents a large part of daily physical activity. It reduces both overall and cardiovascular diseases and mortality and is suitable for cardiac patients. A step counter measures walking activity and might be a motivational tool to increase and maintain physical activity. There is a lack of knowledge about both cardiac patients’ adherence to step counter use in a cardiac telerehabilitation program and how many steps cardiac patients walk up to 1 year after a cardiac event. Objective The purpose of this substudy was to explore cardiac patients’ walking activity. The walking activity was analyzed in relation to duration of pedometer use to determine correlations between walking activity, demographics, and medical and rehabilitation data. Methods A total of 64 patients from a randomized controlled telerehabilitation trial (Teledi@log) from Aalborg University Hospital and Hjoerring Hospital, Denmark, from December 2012 to March 2014 were included in this study. Inclusion criteria were patients hospitalized with acute coronary syndrome, heart failure, and coronary artery bypass grafting or valve surgery. In Teledi@log, the patients received telerehabilitation technology and selected one of three telerehabilitation settings: a call center, a community health care center, or a hospital. Monitoring of steps continued for 12 months and a step counter (Fitbit Zip) was used to monitor daily steps. Results Cardiac patients walked a mean 5899 (SD 3274) steps per day, increasing from mean 5191 (SD 3198) steps per day in the first week to mean 7890 (SD 2629) steps per day after 1 year. Adherence to step counter use lasted for a mean 160 (SD 100) days. The patients who walked significantly more were younger (P=.01) and continued to use the pedometer for a longer period (P=.04). Furthermore, less physically active patients weighed more. There were no significant differences in mean steps per day for patients in the three rehabilitation settings or in the disease groups. Conclusions This study indicates that cardiac telerehabilitation at a call center can support walking activity just as effectively as telerehabilitation at either a hospital or a health care center. In this study, the patients tended to walk fewer steps per day than cardiac patients in comparable studies, but our study may represent a more realistic picture of walking activity due to the continuation of step counter use. Qualitative studies on patients’ behavior and motivation regarding step counter use are needed to shed light on adherence to and motivation to use step counters. Trial Registration ClinicalTrails.gov NCT01752192; https://clinicaltrials.gov/ct2/show/NCT01752192 (Archived by WebCite at http://www.webcitation.org/6fgigfUyV) PMID:27044310

  19. A discrete in continuous mathematical model of cardiac progenitor cells formation and growth as spheroid clusters (Cardiospheres).

    PubMed

    Di Costanzo, Ezio; Giacomello, Alessandro; Messina, Elisa; Natalini, Roberto; Pontrelli, Giuseppe; Rossi, Fabrizio; Smits, Robert; Twarogowska, Monika

    2018-03-14

    We propose a discrete in continuous mathematical model describing the in vitro growth process of biophsy-derived mammalian cardiac progenitor cells growing as clusters in the form of spheres (Cardiospheres). The approach is hybrid: discrete at cellular scale and continuous at molecular level. In the present model, cells are subject to the self-organizing collective dynamics mechanism and, additionally, they can proliferate and differentiate, also depending on stochastic processes. The two latter processes are triggered and regulated by chemical signals present in the environment. Numerical simulations show the structure and the development of the clustered progenitors and are in a good agreement with the results obtained from in vitro experiments.

  20. Recent advances in managing vascular occlusions in the cardiac catheterization laboratory

    PubMed Central

    Qureshi, Athar M.; Mullins, Charles E.; Latson, Larry A.

    2018-01-01

    Vascular occlusions continue to be a significant cause of morbidity and mortality. The management of vascular occlusions in patients is complex, requiring specialized expertise in the cardiac catheterization laboratory and from other disciplines. Knowledge of currently available tools at the operator’s disposal is important to optimize the success of these procedures. In this review, we discuss some of the recent advances in recanalization procedures of vascular occlusions and thrombotic lesions in the cardiac catheterization laboratory. PMID:29770200

  1. State-of-the-art implantable cardiac assist device therapy for heart failure: bridge to transplant and destination therapy.

    PubMed

    Park, S J; Kushwaha, S S; McGregor, C G A

    2012-01-01

    Congestive heart failure is associated with poor quality of life (QoL) and low survival rates. The development of state-of-the-art cardiac devices holds promise for improved therapy in patients with heart failure. The field of implantable cardiac assist devices is changing rapidly with the emergence of continuous-flow pumps (CFPs). The important developments in this field, including pertinent clinical trials, registry reports, innovative research, and potential future directions are discussed in this paper.

  2. Ultrasound Monitoring of Jugular Venous Pulse during Space Missions: Proof of Concept.

    PubMed

    Zamboni, Paolo; Sisini, Francesco; Menegatti, Erica; Taibi, Angelo; Gadda, Giacomo; Tavoni, Valentina; Malagoni, Anna Maria; Tessari, Mirko; Gianesini, Sergio; Gambaccini, Mauro

    2018-03-01

    The jugular venous pulse (JVP) is one of the main parameters of cardiac function and is used by cardiologists in diagnosing heart failure. Its waveform comprises three positive waves (a, c and v) and two negative waves (x and y). Recently, it was found that JVP can be extrapolated from an ultrasound (US) video recording of the internal jugular vein (IJV), suggesting its application in space missions, on which US scanners are already widely used. To date, the feasibility of assessing JVP in microgravity (microG) has not been investigated. To verify the feasibility of JVP assessment in microG, we tested a protocol of self-performed B-mode ultrasound on the International Space Station (ISS). The protocol consisted of a video recording of IJV synchronized with electrocardiogram that produces a cross-sectional area time trace (JVP trace) (in cm 2 ). The scans were acquired in six experimental sessions; two pre-flight (BDC1 and -2), two in space (ISS1 and -2) and two post-flight (Houston PF1, Cologne PF2). We measured the mean and standard deviation of the JVP waves and the phase relationship between such waves and P and T waves on the electrocardiogram. We verified that such parameters had the same accuracy on Earth as they did under microG, and we compared their values. The sensitivity, specificity and accuracy of JVP trace in microgravity are higher than those on Earth. The sequence of (a, c, and v) ascents and (x and y) descents along the cardiac cycle in microG is the same as that on Earth. The cause-and-effect relationship between the P and T waves on the electrocardiogram and a and v waves, respectively, of JVP is also confirmed in microG. Our experiment indicated the feasibility of deriving a JVP trace from a B-mode US examination self-performed by an astronaut in microG. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  3. [Heart rupture in acute myocardial infarction: multicenter observational study of the coronary unit of Piedmont].

    PubMed

    Pron, Paolo Giay; Angelino, Paolo; Varbella, Ferdinando; Bongioanni, Sergio; Masi, Andrea Sibona; Iazzolino, Ernesto; Bonfiglio, Giovanna; Brusin, Maria Cristina Rosa; Mainardi, Loredana; Nicastro, Cristina; Bouslenko, Zoe; Conte, Maria Rosa

    2002-02-01

    The aim of this study was to prospectively evaluate the incidence of cardiac rupture during myocardial infarction (MI) as well as the predictive value of the main cardiac rupture risk factors. The study was carried out in 17 coronary care units (CCU) between January and December 1999 in the Piedmont region (Italy). The incidence of cardiac rupture was 1.4% of the total number of MI (n = 3041). Data from 13 out of 17 CCU showed the following causes of death during MI: 66% heart failure, 16% cardiac rupture, 7% arrhythmias, 11% others. Twenty-seven percent out of 44 cardiac ruptures had prior angina, 9% prior MI; 24% of patients were diabetic; 38% had anterior wall MI; 62% infero-postero-lateral MI; 86% showed ST-segment elevation, and 79.5% developed Q waves. Thrombolysis was administered in 39% of cases. Forty-three percent cardiac ruptures occurred within 24 hours. Electromechanical dissociation was present in 73% of cases, syncope and hypotension in 43%, bradycardia in 30%. An echocardiogram was performed in 89% of cases in the suspicion of cardiac rupture but only 45% showed severe pericardial effusion. One patient was referred to surgery but he died in the postoperative period. Autoptical diagnosis was made in 32% of cases. All patients died. The analysis of some qualitative variables (gender, thrombolysis, MI localization, ST-segment/non-ST-segment elevation) in 8 out of 17 CCU, between the cardiac rupture group (n = 22) and the MI group (n = 1330) showed a significant result only for the female gender. Cardiac rupture is the second cause of death during MI after heart failure; there is a higher incidence of cardiac rupture in infero-postero-lateral MI, after the first 24 hours particularly in the female gender; there is a low global incidence (1.4%).

  4. From door to recovery: a collaborative approach to the development of a post-cardiac arrest center.

    PubMed

    Williams, Donna; Calder, Shelley; Cocchi, Michael N; Donnino, Michael W

    2013-10-01

    Out-of-hospital cardiac arrest remains common and, despite advances in resuscitation practices, continues to carry a high mortality that may be influenced by several factors, including where a patient is cared for after the cardiac arrest. Implementing a post-cardiac arrest care guideline for survivors of out-of-hospital and in-hospital cardiac arrest involves a multidisciplinary approach with short-term and long-term strategies. Physician and nursing leaders must work in synergy to guide the implementation of an evidence-based plan of care. A collaborative approach was used at a hospital to develop processes, build consensus for protocols, and provide support to staff and teams. A joint approach has allowed the hospital to move from traditional silos of individual departmental care to a continuum of patient-focused management after cardiac arrest. This care coordination is initiated in the emergency department and follows the patient through to discharge.

  5. [Cardiac sarcoidosis - clinical manifestation and diagnosis].

    PubMed

    Błaut-Jurkowska, Justyna; Podolec, Piotr; Olszowska, Maria

    2016-08-01

    Sarcoidosis is a multisystem inflammatory disease defined histologically by the formation of noncaseating granulomas. The etiology of sarcoidosis remains unknown. Heart involvement in the course of sarcoidosis concerns about 5% of patients. The most common manifestation of cardiac sarcoidosis are conduction abnormalities, arrhythmias and heart failure. The diagnostic algorithm includes performing a clinical history, a 12-lead electrocardiogram (ECG) and an echocardiogram. If any of the initial screening investigations yields an abnormality, diagnostics should be continue using advanced imaging techniques: cardiovascular magnetic resonance (CMR) or fluorodeoxyglucose positron emission tomography (FDG-PET). Nowadays endomyocardial biopsy is not performed routinely.The clinical picture of cardiac sarcoidosis is highly variable. Screening for cardiac sarcoidosis should be performed in all patients diagnosed with extracardiac sarcoidosis. Cardiac sarcoidosis should also be suspected in young patients without a diagnosis of sarcoidosis who present with conduction abnormalities of unknown etiology, because cardiac sarcoidosis may be the first or the only manifestation of the disease. © 2016 MEDPRESS.

  6. Neural control of heart rate: the role of neuronal networking.

    PubMed

    Kember, G; Armour, J A; Zamir, M

    2011-05-21

    Neural control of heart rate, particularly its sympathetic component, is generally thought to reside primarily in the central nervous system, though accumulating evidence suggests that intrathoracic extracardiac and intrinsic cardiac ganglia are also involved. We propose an integrated model in which the control of heart rate is achieved via three neuronal "levels" representing three control centers instead of the conventional one. Most importantly, in this model control is effected through networking between neuronal populations within and among these layers. The results obtained indicate that networking serves to process demands for systemic blood flow before transducing them to cardiac motor neurons. This provides the heart with a measure of protection against the possibility of "overdrive" implied by the currently held centrally driven system. The results also show that localized networking instabilities can lead to sporadic low frequency oscillations that have the characteristics of the well-known Mayer waves. The sporadic nature of Mayer waves has been unexplained so far and is of particular interest in clinical diagnosis. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. A Head Start to a Healthy Heart

    NASA Technical Reports Server (NTRS)

    2002-01-01

    Cambridge Heart, Inc., has licensed the only U.S. Food and Drug Administration-cleared tool to identify those at risk for sudden cardiac death (SCD). The Microvolt T-Wave Alternans Test(TM) was invented by Dr. Richard J. Cohen, a professor at the Harvard-Massachusetts Institute of Technology (MIT) Division of Health Sciences and Technology, with developmental support and funding from NASA's Johnson Space Center and the National Space Biomedical Research Institute (NSBRI) in Houston, Texas. In 1993, MIT licensed the technology to Cambridge Heart, Inc., a start-up company that Dr. Cohen helped to establish. Cambridge Heart's non-invasive technology measures T-wave alternans, a change from one heartbeat to the next that is too minute to be detected by a standard electrocardiogram. Cardiac patients with such a change in heartbeat regulation are faced with a much greater risk of ventricular arrhythmia and SCD than those without it. The company's ability to measure electrical alternans on a microvolt level has been clinically proven to be just as accurate as - and in some studies, more accurate than - more costly and somewhat risky, invasive procedures, such as electrophysiological testing.

  8. [Sudden cardiac death, a major scientific challenge].

    PubMed

    Haissaguerre, Michel; Hocini, Meleze; Sacher, Frédéric; Shah, Ashok

    2010-06-01

    Sudden death is responsible for 350,000 deaths each year in Europe, or 1000 deaths each day, equivalent to the combined mortality from the most lethal cancers (breast, lung and colorectal). Unfortunately, sudden death is widely considered to be "natural", being due to unknown but critical cardiac disorders leading to sudden arrest of cardiac activity. Awareness of its potential preventability is inadequate. Indeed, 80% of cases of sudden death are associated with extremely rapid heartbeats, an "electric tornado" called ventricular fibrillation, caused by ultrarapid firing of ectopic foci or chaotic wave propagation. This arrhythmia strikes like lightning Although it can be associated with myocardial infarction, most victims have structurally normal or slightly altered hearts. The cells which cause this ultrarapid firing originate from the Purkinje system, which constitutes just a fraction (2%) of total cardiac mass. This is borne out by the fact that the risk of fatal arrhythmic events can be reduced by focal thermoablation. What is most important is to identify subjects at risk of such events. It has been suggested that there exists an unidentified subclinical electrical disharmony, which converts into a tornado of ultimately fatal clinical events at a certain threshold level. High-resolution bioelectrical cardiac mapping, functional imaging, and treatment of electrical field disorders are major scientific challenges given their complexity, intraindividual dynamics and interindividual variability.

  9. The development of a combined b-mode, ARFI, and spectral Doppler ultrasound imaging system for investigating cardiovascular stiffness and hemodynamics

    NASA Astrophysics Data System (ADS)

    Doherty, Joshua R.; Dumont, Douglas M.; Trahey, Gregg E.

    2011-03-01

    The progression of atherosclerotic disease, caused by the formation of plaques within arteries, is a complex process believed to be a function of the localized mechanical properties and hemodynamic loading associated with the arterial wall. It is hypothesized that measurements of vascular stiffness and wall-shear rate (WSR) may provide important information regarding vascular remodeling, endothelial function, and the growth of soft-lipid filled plaques that could help a clinician better diagnose a patient's risk of clinical events such as stroke. To that end, the approach taken in this work was to combine conventional B-mode, Acoustic Radiation Force Impulse (ARFI), Shear Wave Elasticity Imaging (SWEI), and spectral Doppler techniques into a single imaging system capable of simultaneously measuring the tissue displacements and WSR throughout the cardiac cycle and over several heartbeats. Implemented on a conventional scanner, the carotid arteries of human subjects were scanned to demonstrate the initial in vivo feasibility of the method. Two non-invasive ultrasound based imaging methods, SAD-SWEI and SAD-Gated Imaging, were developed that measure ARF-induced on-axis tissue displacements, off-axis transverse wave velocities, and WSR throughout the cardiac cycle. Human carotid artery scans were performed in vivo on 5 healthy subjects. Statistical differences were observed in both on-axis proximal wall displacements and transverse wave velocities during diastole compared to systole.

  10. Right Ventricular Outflow Tract Septal Pacing Is Superior to Right Ventricular Apical Pacing

    PubMed Central

    Zou, Cao; Song, Jianping; Li, Hui; Huang, Xingmei; Liu, Yuping; Zhao, Caiming; Shi, Xin; Yang, Xiangjun

    2015-01-01

    Background The effects of right ventricular apical pacing (RVAP) and right ventricular outflow tract (RVOT) septal pacing on atrial and ventricular electrophysiology have not been thoroughly compared. Methods and Results To identify a more favorable pacing strategy with fewer adverse effects, 80 patients who had complete atrioventricular block with normal cardiac function and who were treated with either RVAP (n=42) or RVOT septal pacing (n=38) were recruited after an average of 2 years of follow‐up. The data from electrocardiography and echocardiography performed before pacemaker implantation and at the end of follow‐up were collected. The patients in the RVOT septal pacing and RVAP groups showed similar demographic and clinical characteristics before pacing treatments. After a mean follow‐up of 2 years, the final maximum P‐wave duration; P‐wave dispersion; Q‐, R‐, and S‐wave complex duration; left atrial volume index; left ventricular end‐systolic diameter; ratio of transmitral early diastolic filling velocity to mitral annular early diastolic velocity; and interventricular mechanical delay in the RVOT septal pacing group were significantly less than those in the RVAP group (P<0.05). The final left ventricular ejection fraction of the RVOT septal pacing group was significantly higher than that of the RVAP group (P<0.05). Conclusions Compared with RVAP, RVOT septal pacing has fewer adverse effects regarding atrial electrical activity and structure in patients with normal cardiac function. PMID:25896891

  11. Improvement of Shear Wave Motion Detection Using Harmonic Imaging in Healthy Human Liver.

    PubMed

    Amador, Carolina; Song, Pengfei; Meixner, Duane D; Chen, Shigao; Urban, Matthew W

    2016-05-01

    Quantification of liver elasticity is a major application of shear wave elasticity imaging (SWEI) to non-invasive assessment of liver fibrosis stages. SWEI measurements can be highly affected by ultrasound image quality. Ultrasound harmonic imaging has exhibited a significant improvement in ultrasound image quality as well as for SWEI measurements. This was previously illustrated in cardiac SWEI. The purpose of this study was to evaluate liver shear wave particle displacement detection and shear wave velocity (SWV) measurements with fundamental and filter-based harmonic ultrasound imaging. In a cohort of 17 patients with no history of liver disease, a 2.9-fold increase in maximum shear wave displacement, a 0.11 m/s decrease in the overall interquartile range and median SWV and a 17.6% increase in the success rate of SWV measurements were obtained when filter-based harmonic imaging was used instead of fundamental imaging. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  12. Safety of capsule endoscopy using human body communication in patients with cardiac devices.

    PubMed

    Chung, Joo Won; Hwang, Hye Jin; Chung, Moon Jae; Park, Jeong Youp; Pak, Hui-Nam; Song, Si Young

    2012-06-01

    The MiroCam (IntroMedic, Ltd., Seoul, Korea) is a small-bowel capsule endoscope that uses human body communication to transmit data. The potential interactions between cardiac devices and the capsule endoscope are causes for concern, but no data are available for this matter. This clinical study was designed to evaluate the potential influence of the MiroCam capsules on cardiac devices. Patients with cardiac pacemakers or implantable cardiac defibrillators referred for evaluation of small bowel disease were prospectively enrolled in this study. Before capsule endoscopy, a cardiologist checked baseline electrocardiograms and functions of the cardiac devices. Cardiac rhythms were continuously monitored by 24-h telemetry during capsule endoscopy in the hospital. After completion of procedures, functions of the cardiac devices were checked again for interference. Images from the capsule endoscopy were reviewed and analyzed for technical problems. Six patients, three with pacemakers and three with implantable cardiac defibrillators, were included in the study. We identified no disturbances in the cardiac devices and no arrhythmias detected on telemetry monitoring during capsule endoscopy. No significant changes in the programmed parameters of the cardiac devices were noted after capsule endoscopy. There were no imaging disturbances from the cardiac devices on capsule endoscopy. Capsule endoscopy using human body communication to transmit data was safely performed in patients with cardiac pacemakers or implantable cardiac defibrillators. Images from the capsule endoscopy were not affected by cardiac devices. A further large-scale study is required to confirm the safety of capsule endoscopy with various types of cardiac devices.

  13. Non-contact arrhythmia assessment in natural settings: a step toward preventive cardiac care

    NASA Astrophysics Data System (ADS)

    Amelard, Robert; Hughson, Richard L.; Clausi, David A.; Wong, Alexander

    2017-02-01

    Cardiovascular disease is a major contributor to US morbidity. Taking preventive action can greatly reduce or eliminate the impact on quality of life. However, many issues often go undetected until the patient presents a physical symptom. Non-intrusive continuous cardiovascular monitoring systems may make detecting and monitoring abnormalities earlier feasible. One candidate system is photoplethysmographic imaging (PPGI), which is able to assess arterial blood pulse characteristics in one or multiple individuals remotely from a distance. In this case study, we showed that PPGI can be used to detect cardiac arrhythmia that would otherwise require contact-based monitoring techniques. Using a novel system, coded hemodynamic imaging (CHI), strong temporal blood pulse waveform signals were extracted at a distance of 1.5 m from the participant using 850-1000 nm diffuse illumination for deep tissue penetration. Data were recorded at a sampling rate of 60 Hz, providing a temporal resolution of 17 ms. The strong fidelity of the signal allowed for both temporal and spectral assessment of abnormal blood pulse waveforms, ultimately to detect the onset of abnormal cardiac events. Data from a participant with arrhythmia was analyzed and compared against normal blood pulse waveform data to validate CHI's ability to assess cardiac arrhythmia. Results indicate that CHI can be used as a non-intrusive continuous cardiac monitoring system.

  14. Electrocardiogram Changes with Acute Alcohol Intoxication: A Systematic Review.

    PubMed

    Raheja, Hitesh; Namana, Vinod; Chopra, Kirti; Sinha, Ankur; Gupta, Sushilkumar Satish; Kamholz, Stephan; Moskovits, Norbert; Shani, Jacob; Hollander, Gerald

    2018-01-01

    Acute alcohol intoxication has been associated with cardiac arrhythmias but the electrocardiogram (ECG) changes associated with acute alcohol intoxication are not well defined in the literature. Highlight the best evidence regarding the ECG changes associated with acute alcohol intoxication in otherwise healthy patients and the pathophysiology of the changes. A literature search was carried out; 4 studies relating to ECG changes with acute alcohol intoxication were included in this review. Of the total 141 patients included in the review, 90 (63.8%) patients had P-wave prolongation, 80 (56%) patients had QTc prolongation, 19 (13.5%) patients developed T-wave abnormalities, 10 (7%) patients had QRS complex prolongation, 3 (2.12%) patients developed ST-segment depressions. The most common ECG changes associated with acute alcohol intoxication are (in decreasing order of frequency) P-wave and QTc prolongation, followed by T-wave abnormalities and QRS complex prolongation. Mostly, these changes are completely reversible.

  15. 21 CFR 868.5365 - Posture chair for cardiac or pulmonary treatment.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Posture chair for cardiac or pulmonary treatment. 868.5365 Section 868.5365 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5365 Posture chair...

  16. Smoking and Cardiac Rehabilitation Participation: Associations with Referral, Attendance and Adherence

    PubMed Central

    Gaalema, Diann E.; Cutler, Alexander Y.; Higgins, Stephen T.; Ades, Philip A.

    2015-01-01

    Objective Continued smoking after a cardiac event greatly increases mortality risk. Smoking cessation and participation in cardiac rehabilitation (CR) are effective in reducing morbidity and mortality. However, these two behaviors may interact; those who smoke may be less likely to access or complete CR. This review explores the association between smoking status and CR referral, attendance, and adherence. Methods A systematic literature search was conducted examining associations between smoking status and CR referral, attendance and completion in peer-reviewed studies published through July 1st, 2014. For inclusion, studies had to report data on outpatient CR referral, attendance or completion rates and smoking status had to be considered as a variable associated with these outcomes. Results Fifty-six studies met inclusion criteria. In summary, a history of smoking was associated with an increased likelihood of referral to CR. However, smoking status also predicted not attending CR and was a strong predictor of CR dropout. Conclusion Continued smoking after a cardiac event predicts lack of attendance in, and completion of CR. The issue of smoking following a coronary event deserves renewed attention. PMID:25900804

  17. Patterns of Heterotypic Continuity Associated With the Cross-Sectional Correlational Structure of Prevalent Mental Disorders in Adults

    PubMed Central

    Lahey, Benjamin B.; Zald, David H.; Hakes, Jahn K.; Krueger, Robert F.; Rathouz, Paul J.

    2014-01-01

    Importance Mental disorders predict future occurrences of both the same disorder (homotypic continuity) and other disorders (heterotypic continuity). Heterotypic continuity is inconsistent with a view of mental disorders as fixed entities. In contrast, hierarchical-dimensional conceptualizations of psychopathology, in which each form of psychopathology is hypothesized to have both unique and broadly shared etiologies and mechanisms, predict both homotypic and heterotypic continuity. Objective To test predictions derived from a hierarchical-dimensional model of psychopathology that (a) heterotypic continuity is widespread, even controlling for homotypic continuity, and (b) the relative magnitudes of heterotypic continuities recapitulate the relative magnitudes of cross-sectional correlations among diagnoses at baseline. Design Assess 10 prevalent diagnoses in the same persons 3 years apart. Setting Representative sample of adults in the United States. Participants The 28,958 participants in the National Epidemiologic Study of Alcohol and Related Condition aged 18–64 years who were assessed in both waves. Main Outcome Measure Diagnoses from reliable and valid structured interviews. Results Bivariate associations of all pairs of diagnoses from wave 1 to wave 2 exceeded chance levels for all homotypic (tetrachoric ρ = 0.41 – 0.79, median = 0.54) and for nearly all heterotypic continuities (tetrachoric ρ = 0.07 – 0.50, median = 0.28), adjusted for sex and age. Significant heterotypic continuity was widespread even when all other wave 1 diagnoses (including the same diagnosis) were simultaneous predictors of each wave 2 diagnosis. The rank correlation between age and sex adjusted tetrachoric ρs for cross-sectional associations among wave 1 diagnoses and heterotypic associations from wave 1 to wave 2 diagnoses was ρ = .86. Conclusions and Relevance For these prevalent mental disorders, heterotypic continuity was nearly universal and not an artifact of failure to control for homotypic continuity. Furthermore, the relative magnitudes of heterotypic continuity closely mirrored the relative magnitudes of cross-sectional associations among these disorders, consistent with the hypothesis that both sets of associations reflect the same factors. Mental disorders are not fixed and independent entities. Rather, each diagnosis is robustly related to other diagnoses in a correlational structure that is manifested both concurrently and in patterns of heterotypic continuity across time. PMID:24989054

  18. Assessing the Atrial Electromechanical Coupling during Atrial Focal Tachycardia, Flutter, and Fibrillation using Electromechanical Wave Imaging in Humans

    PubMed Central

    Provost, Jean; Costet, Alexandre; Wan, Elaine; Gambhir, Alok; Whang, William; Garan, Hasan; Konofagou, Elisa E.

    2015-01-01

    Minimally-invasive treatments of cardiac arrhythmias such as radio-frequency ablation are gradually gaining in importance in clinical practice but still lack a noninvasive imaging modality which provides insight into the source or focus of an arrhythmia. Cardiac deformations imaged at high temporal and spatial resolution can be used to elucidate the electrical activation sequence in normal and paced human subjects non-invasively and could potentially aid to better plan and monitor ablation-based arrhythmia treatments. In this study, a novel ultrasound-based method is presented that can be used to quantitatively characterize focal and reentrant arrhythmias. Spatio-temporal maps of the full-view of the atrial and ventricular mechanics were obtained in a single heartbeat, revealing with otherwise unobtainable detail the electromechanical patterns of atrial flutter, fibrillation, and tachycardia in humans. During focal arrhythmias such as premature ventricular complex and focal atrial tachycardia, the previously developed electromechanical wave imaging methodology is hereby shown capable of identifying the location of the focal zone and the subsequent propagation of cardiac activation. During reentrant arrhythmias such as atrial flutter and fibrillation, Fourier analysis of the strains revealed highly correlated mechanical and electrical cycle lengths and propagation patterns. High frame rate ultrasound imaging of the heart can be used non-invasively and in real time, to characterize the lesser-known mechanical aspects of atrial and ventricular arrhythmias, also potentially assisting treatment planning for intraoperative and longitudinal monitoring of arrhythmias. PMID:26361338

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moroz, B.B.; Grozdou, S.P.

    Electrocardiographic data are presented on the reaction of the myocardium to adrenaline, carbocholine, ephedrin, and nitroglycerin in rabbits at different stages of acute radiation sickness induced by polonium. There were divulged changes in the excitability and conductivity of the myocardium in which two developmental stages could be distinguished. In the first stage the sensitivity of the heart was elevated. After the introduction of adrenaline, bradycardia intensified, exrasystoles were observed more often and ventricular flutter and heterotopic ventricular rhythm. was observed. The administration of carbocholine produced a sharper retardation of atrioventricular conductivity, even an incomplete block of the II to IIImore » degree, etc. In the second stage, as compared with the early periods of radiation sickness, a drop of cardiac sensitivity was observed. The reactivity of the heart to adrenaline, carbocholine, and nitroglycerin, especially at late stages, was considerably reduced or the myocardial reaction was absent completely. At the peak of radiation sickness marked changes of the electrocardiogram were seen which were indicative of dystrophic processes in the myocardium (a drop of the wave P amplitude and QRS complex, a rise and a sharpening of T wave a lengthening of the QRST complex, and displacement of the isoelectric axis to the right). An elevated sensitivity of the heart during the first stage was apparently associated with disturbances of extracardiac innervation, especially with the increase of parasympathetic influences. A diminution of the cardiac reaction in the second stage was possibly due to a weakening of extracardiac reflexes and affection of the cardiac muscle as well. (auth)« less

  20. 3D Myocardial Elastography In Vivo.

    PubMed

    Papadacci, Clement; Bunting, Ethan A; Wan, Elaine Y; Nauleau, Pierre; Konofagou, Elisa E

    2017-02-01

    Strain evaluation is of major interest in clinical cardiology as it can quantify the cardiac function. Myocardial elastography, a radio-frequency (RF)-based cross-correlation method, has been developed to evaluate the local strain distribution in the heart in vivo. However, inhomogeneities such as RF ablation lesions or infarction require a three-dimensional approach to be measured accurately. In addition, acquisitions at high volume rate are essential to evaluate the cardiac strain in three dimensions. Conventional focused transmit schemes using 2D matrix arrays, trade off sufficient volume rate for beam density or sector size to image rapid moving structure such as the heart, which lowers accuracy and precision in the strain estimation. In this study, we developed 3D myocardial elastography at high volume rates using diverging wave transmits to evaluate the local axial strain distribution in three dimensions in three open-chest canines before and after radio-frequency ablation. Acquisitions were performed with a 2.5 MHz 2D matrix array fully programmable used to emit 2000 diverging waves at 2000 volumes/s. Incremental displacements and strains enabled the visualization of rapid events during the QRS complex along with the different phases of the cardiac cycle in entire volumes. Cumulative displacement and strain volumes depict high contrast between non-ablated and ablated myocardium at the lesion location, mapping the tissue coagulation. 3D myocardial strain elastography could thus become an important technique to measure the regional strain distribution in three dimensions in humans.

  1. Repeatability, variability and reference values of pulsed wave Doppler echocardiographic measurements in healthy Saanen goats

    PubMed Central

    2012-01-01

    Background Pulsed wave (PW) Doppler echocardiography has become a routine non invasive cardiac diagnostic tool in most species. However, evaluation of intracardiac blood flow requires reference values, which are poorly documented in goats. The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy adult Saanen goats. Using a standardised PW Doppler echocardiographic protocol, 10 healthy adult unsedated female Saanen goats were investigated three times at one day intervals by the same observer. Mitral, tricuspid, aortic and pulmonary flows were measured from a right parasternal view, and mitral and aortic flows were also measured from a left parasternal view. The difference between left and right side measurements and the intra-observer inter-day repeatability were tested and then the reference values of PW Doppler echocardiographic parameters in healthy adult female Saanen goats were established. Results As documented in other species, all caprine PW Doppler parameters demonstrated a poor inter-day repeatability and a moderate variability. Tricuspid and pulmonary flows were best evaluated on the right side whereas mitral and aortic flows were best obtained on the left side, and reference values are reported for healthy adult Saanen goats. Conclusions PW Doppler echocardiography allows the measurement of intracardiac blood flow indices in goats. The reference values establishment will help interpreting these indices of cardiac function in clinical cardiac cases and developing animal models for human cardiology research. PMID:23067875

  2. Influence of the heart rate and atrioventricular delays on vortex evolution and blood transport inside the left ventricle

    NASA Astrophysics Data System (ADS)

    Hendabadi, Sahar; Martinez-Legazpi, Pablo; Benito, Yolanda; Bermejo, Javier; Del Alamo, Juan Carlos; Shadden, Shawn

    2013-11-01

    Cardiac resynchronization therapy (CRT) is used to help restore coordinated pumping of the ventricles by overcoming delays in electrical conduction due to cardiac disease. This is accomplished by a specialized cardiac pacemaker that is able to adjust the atrioventricular (AV) delay.A major clinical challenge is to adjust the pacing strategy to best coordinate the blood flow mechanics of ventricular filling and ejection. To this end, we have studied the difference in the vortex formation and its evolution inside the left ventricle (LV) for 4 different AV delays in a cohort of patients with implanted pacemakers. A reconstruction algorithm was used to obtain 2D velocity over the apical long-axis view of the LV from color Doppler and B-mode ultrasound data. To study blood transport, we have identified Lagrangian coherent structures to determine moving boundaries of the blood volumes injected to the LV in diastole and ejected to the aorta in systole. In all cases, we have analyzed the differences in filling and ejection patterns and the blood transport during the E-wave and A-wave formation.Finally we have assessed the influence of the AV delay on 2 indices of stasis, direct flow and residence time.The findings shed insight to the optimization of AV delays in patients undergoing CRT. NIH award 5R21HL108268 and grants PIS09/02603 and RD06/0010 from the Plan Nacional de Investigacion Cientifica, Spain.

  3. Translational Symmetry-Breaking for Spiral Waves

    NASA Astrophysics Data System (ADS)

    LeBlanc, V. G.; Wulff, C.

    2000-10-01

    Spiral waves are observed in numerous physical situations, ranging from Belousov-Zhabotinsky (BZ) chemical reactions, to cardiac tissue, to slime-mold aggregates. Mathematical models with Euclidean symmetry have recently been developed to describe the dynamic behavior (for example, meandering) of spiral waves in excitable media. However, no physical experiment is ever infinite in spatial extent, so the Euclidean symmetry is only approximate. Experiments on spiral waves show that inhomogeneities can anchor spirals and that boundary effects (for example, boundary drifting) become very important when the size of the spiral core is comparable to the size of the reacting medium. Spiral anchoring and boundary drifting cannot be explained by the Euclidean model alone. In this paper, we investigate the effects on spiral wave dynamics of breaking the translation symmetry while keeping the rotation symmetry. This is accomplished by introducing a small perturbation in the five-dimensional center bundle equations (describing Hopf bifurcation from one-armed spiral waves) which is SO(2)-equivariant but not equivariant under translations. We then study the effects of this perturbation on rigid spiral rotation, on quasi-periodic meandering and on drifting.

  4. Is an Abnormal ECG Just the Tip of the ICE-berg? Examining the Utility of Electrocardiography in Detecting Methamphetamine-Induced Cardiac Pathology.

    PubMed

    Paratz, Elizabeth D; Zhao, Jessie; Sherwen, Amanda K; Scarlato, Rose-Marie; MacIsaac, Andrew I

    2017-07-01

    Methamphetamine use is escalating in Australia and New Zealand, with increasing emergency department attendance and mortality. Cardiac complications play a large role in methamphetamine-related mortality, and it would be informative to assess the frequency of abnormal electrocardiograms (ECGs) amongst methamphetamine users. To determine the frequency and severity of ECG abnormalities amongst methamphetamine users compared to a control group. We conducted a retrospective cohort analysis on 212 patients admitted to a tertiary hospital (106 patients with methamphetamine use, 106 age and gender-matched control patients). Electrocardiograms were analysed according to American College of Cardiology guidelines. Mean age was 33.4 years, with 73.6% male gender, with no significant differences between groups in smoking status, ECG indication, or coronary angiography rates. Methamphetamine users were more likely to have psychiatric admissions (22.6% vs 1.9%, p<0.0001). Overall, ECG abnormalities were significantly more common (71.7% vs 32.1%, p<0.0001) in methamphetamine users, particularly tachyarrhythmias (38.7% vs 26.4%, p<0.0001), right axis deviation (7.5% vs 0.0%, p=0.004), left ventricular hypertrophy (26.4% vs 4.7%, p<0.0001), P pulmonale pattern (7.5% vs 0.9%, p=0.017), inferior Q waves (10.4% vs 0.0%, p=0.001), lateral T wave inversion (3.8% vs 0.0%, p=0.043), and longer QTc interval (436.41±31.61ms vs 407.28±24.38ms, p<0.0001). Transthoracic echocardiogram (n=24) demonstrated left ventricular dysfunction (38%), thrombus (8%), valvular lesions (17%), infective endocarditis (17%), and pulmonary hypertension (13%). Electrocardiograms were only moderately sensitive at predicting abnormal TTE. Electrocardiographic abnormalities are more common in methamphetamine users than age and gender-matched controls. Due to the high frequency of abnormalities, ECGs should be performed in all methamphetamine users who present to hospital. Methamphetamine users with abnormal ECGs should undergo further cardiac investigations. Copyright © 2016 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). All rights reserved.

  5. Left ventricle: fully automated segmentation based on spatiotemporal continuity and myocardium information in cine cardiac magnetic resonance imaging (LV-FAST).

    PubMed

    Wang, Lijia; Pei, Mengchao; Codella, Noel C F; Kochar, Minisha; Weinsaft, Jonathan W; Li, Jianqi; Prince, Martin R; Wang, Yi

    2015-01-01

    CMR quantification of LV chamber volumes typically and manually defines the basal-most LV, which adds processing time and user-dependence. This study developed an LV segmentation method that is fully automated based on the spatiotemporal continuity of the LV (LV-FAST). An iteratively decreasing threshold region growing approach was used first from the midventricle to the apex, until the LV area and shape discontinued, and then from midventricle to the base, until less than 50% of the myocardium circumference was observable. Region growth was constrained by LV spatiotemporal continuity to improve robustness of apical and basal segmentations. The LV-FAST method was compared with manual tracing on cardiac cine MRI data of 45 consecutive patients. Of the 45 patients, LV-FAST and manual selection identified the same apical slices at both ED and ES and the same basal slices at both ED and ES in 38, 38, 38, and 41 cases, respectively, and their measurements agreed within -1.6 ± 8.7 mL, -1.4 ± 7.8 mL, and 1.0 ± 5.8% for EDV, ESV, and EF, respectively. LV-FAST allowed LV volume-time course quantitatively measured within 3 seconds on a standard desktop computer, which is fast and accurate for processing the cine volumetric cardiac MRI data, and enables LV filling course quantification over the cardiac cycle.

  6. Continuous bilateral thoracic paravertebral blockade for analgesia after cardiac surgery: a randomised, controlled trial.

    PubMed

    Lockwood, Geoff G; Cabreros, Leilani; Banach, Dorota; Punjabi, Prakash P

    2017-10-01

    Continuous bilateral thoracic paravertebral blockade has been used for analgesia after cardiac surgery, but its efficacy has never been formally tested. Fifty adult patients were enrolled in a double-blind, randomised, controlled study of continuous bilateral thoracic paravertebral infusion of 0.5% lidocaine (1 mg.kg -1 .hr -1 ) for analgesia after coronary surgery. Control patients received a subcutaneous infusion of lidocaine at the same rate through catheters inserted at the same locations as the study group. The primary outcome was morphine consumption at 48 hours using patient-controlled analgesia (PCA). Secondary outcomes included pain, respiratory function, nausea and vomiting. Serum lidocaine concentrations were measured on the first two post-operative days. There was no difference in morphine consumption or in any other outcome measure between the groups. Serum lidocaine concentrations increased during the study, with a maximum of 5.9 mg.l -1 . There were no adverse events as a consequence of the study. Bilateral paravertebral infusion of lidocaine confers no advantage over systemic lidocaine infusion after cardiac surgery. ISRCTN13424423 ( https://www.isrctn.com ).

  7. Effects of early afterdepolarizations on excitation patterns in an accurate model of the human ventricles

    PubMed Central

    Seemann, Gunnar; Panfilov, Alexander V.; Vandersickel, Nele

    2017-01-01

    Early Afterdepolarizations, EADs, are defined as the reversal of the action potential before completion of the repolarization phase, which can result in ectopic beats. However, the series of mechanisms of EADs leading to these ectopic beats and related cardiac arrhythmias are not well understood. Therefore, we aimed to investigate the influence of this single cell behavior on the whole heart level. For this study we used a modified version of the Ten Tusscher-Panfilov model of human ventricular cells (TP06) which we implemented in a 3D ventricle model including realistic fiber orientations. To increase the likelihood of EAD formation at the single cell level, we reduced the repolarization reserve (RR) by reducing the rapid delayed rectifier Potassium current and raising the L-type Calcium current. Varying these parameters defined a 2D parametric space where different excitation patterns could be classified. Depending on the initial conditions, by either exciting the ventricles with a spiral formation or burst pacing protocol, we found multiple different spatio-temporal excitation patterns. The spiral formation protocol resulted in the categorization of a stable spiral (S), a meandering spiral (MS), a spiral break-up regime (SB), spiral fibrillation type B (B), spiral fibrillation type A (A) and an oscillatory excitation type (O). The last three patterns are a 3D generalization of previously found patterns in 2D. First, the spiral fibrillation type B showed waves determined by a chaotic bi-excitable regime, i.e. mediated by both Sodium and Calcium waves at the same time and in same tissue settings. In the parameter region governed by the B pattern, single cells were able to repolarize completely and different (spiral) waves chaotically burst into each other without finishing a 360 degree rotation. Second, spiral fibrillation type A patterns consisted of multiple small rotating spirals. Single cells failed to repolarize to the resting membrane potential hence prohibiting the Sodium channel gates to recover. Accordingly, we found that Calcium waves mediated these patterns. Third, a further reduction of the RR resulted in a more exotic parameter regime whereby the individual cells behaved independently as oscillators. The patterns arose due to a phase-shift of different oscillators as disconnection of the cells resulted in continuation of the patterns. For all patterns, we computed realistic 9 lead ECGs by including a torso model. The B and A type pattern exposed the behavior of Ventricular Tachycardia (VT). We conclude that EADs at the single cell level can result in different types of cardiac fibrillation at the tissue and 3D ventricle level. PMID:29216239

  8. Electromuscular incapacitating devices discharge and risk of severe bradycardia.

    PubMed

    Havranek, Stepan; Neuzil, Petr; Linhart, Ales

    2015-06-01

    Electromuscular incapacitating devices (EMDs) are high-voltage, low-current stimulators causing involuntary muscle contractions and sensory response. Existing evidence about cardiac effects of EMD remains inconclusive. The aim of our study was to analyze electrocardiographic, echocardiographic, and microvolt T-wave alternans (MTWA) changes induced by EMD discharge.We examined 26 volunteers (22 men; median age 30 years) who underwent single standard 5-second duration exposure to TASER X26 under continuous echocardiographic and electrocardiographic monitoring. Microvolt T-wave alternans testing was performed at baseline (MTWA-1), as well as immediately and 60 minutes after EMD exposure (MTWA-2 and MTWA-3, respectively).Mean heart rate (HR) increased significantly from 88 ± 17 beats per minute before to 129 ± 17 beats per minute after exposure (P < 0.001). However, in 2 individuals, an abrupt decrease in HR was observed. In one of them, interval between two consecutive beats increased up to 1.7 seconds during the discharge. New onset of supraventricular premature beats was observed after discharge in 1 patient. Results of MTWA-1, MTWA-2, and MTWA-3 tests were positive in one of the subjects, each time in a different case.Standard EMD exposure can be associated with a nonuniform reaction of HR and followed by heart rhythm disturbances. New MTWA positivity can reflect either the effect of EMD exposure or a potential false positivity of MTWA assessments.

  9. Response of a hypersonic boundary layer to freestream pulse acoustic disturbance.

    PubMed

    Wang, Zhenqing; Tang, Xiaojun; Lv, Hongqing

    2014-01-01

    The response of hypersonic boundary layer over a blunt wedge to freestream pulse acoustic disturbance was investigated. The stability characteristics of boundary layer for freestream pulse wave and continuous wave were analyzed comparatively. Results show that freestream pulse disturbance changes the thermal conductivity characteristics of boundary layer. For pulse wave, the number of main disturbance clusters decreases and the frequency band narrows along streamwise. There are competition and disturbance energy transfer among different modes in boundary layer. The dominant mode of boundary layer has an inhibitory action on other modes. Under continuous wave, the disturbance modes are mainly distributed near fundamental and harmonic frequencies, while under pulse wave, the disturbance modes are widely distributed in different modes. For both pulse and continuous waves, most of disturbance modes slide into a lower-growth or decay state in downstream, which is tending towards stability. The amplitude of disturbance modes in boundary layer under continuous wave is considerably larger than pulse wave. The growth rate for the former is also considerably larger than the later the disturbance modes with higher growth are mainly distributed near fundamental and harmonic frequencies for the former, while the disturbance modes are widely distributed in different frequencies for the latter.

  10. Response of a Hypersonic Boundary Layer to Freestream Pulse Acoustic Disturbance

    PubMed Central

    Wang, Zhenqing; Tang, Xiaojun; Lv, Hongqing

    2014-01-01

    The response of hypersonic boundary layer over a blunt wedge to freestream pulse acoustic disturbance was investigated. The stability characteristics of boundary layer for freestream pulse wave and continuous wave were analyzed comparatively. Results show that freestream pulse disturbance changes the thermal conductivity characteristics of boundary layer. For pulse wave, the number of main disturbance clusters decreases and the frequency band narrows along streamwise. There are competition and disturbance energy transfer among different modes in boundary layer. The dominant mode of boundary layer has an inhibitory action on other modes. Under continuous wave, the disturbance modes are mainly distributed near fundamental and harmonic frequencies, while under pulse wave, the disturbance modes are widely distributed in different modes. For both pulse and continuous waves, most of disturbance modes slide into a lower-growth or decay state in downstream, which is tending towards stability. The amplitude of disturbance modes in boundary layer under continuous wave is considerably larger than pulse wave. The growth rate for the former is also considerably larger than the later the disturbance modes with higher growth are mainly distributed near fundamental and harmonic frequencies for the former, while the disturbance modes are widely distributed in different frequencies for the latter. PMID:24737993

  11. Forward and Backward Aortic Components and Reflection Indexes in Children and Adolescents: Determinants and Role in High Pressure States.

    PubMed

    Zocalo, Yanina; Castro, Juan M; Garcia-Espinosa, Victoria; Curcio, Santiago; Chiesa, Pedro; Giachetto, Gustavo; Cabrera-Fischer, Edmundo I; Bia, Daniel

    2018-04-12

    High blood pressure states (HBP) would differ in wave components and reflections indexes, which could associate clinical and prognostic implications. 1) to characterize the association of aortic wave components and reflection parameters (backward [Pb], forward [Pf], Pb/Pf ratio and augmentation index [AIx]) with demographic, anthropometric, hemodynamic and arterial parameters in healthy children and adolescents; 2) to generate multivariate prediction models for the associations, to contribute to understand main determinants of Pf, Pb, Pb/Pf and AIx; 3) to identify if differences in wave reflection indexes observed in HBP could be explained by differences in the analyzed parameters. Healthy children and adolescents (n=816, females: 386; Age: 3-20 years) were studied. central aortic pressure and wave components (Pb, Pf, Pb/Pf and AIx determination with SphygmoCor [SCOR] and Mobil-o-Graph [MOG]); anthropometric assessment; regional arterial stiffness (carotid-femoral, carotid-radial pulse wave velocity [PWV] and PWV ratio); carotid intima-media thickness; carotid and femoral distensbility; cardiac output; systemic vascular resistances (SVR). Simple and multiple regression models were constructed to determine aortic wave parameters main explanatory variables. Normotensive and HBP groups were compared. Differences in wave reflection indexes were analyzed before and after controlling for explanatory variables. Equivalences between SphygmoCor and Mobil-O-Graph data were assessed (correlation and Bland-Altman analyses). There were systematic and proportional differences between data obtained with SphygmoCor and Mobil-O-Graph devices. Heart rate (HR), peripheral pulse pressure, height and weight were the variables that isolated (simple associations) or combined (multiple associations) showed the major capability to explain interindividual differences in Pf, Pb, Pb/Pf and AIx. Arterial stiffness also showed explanatory capacity, being the carotid the artery with major contribution. HBP associated higher Pf, Pb, AIx and lower Pb/Pf ratio. Those findings were observed together with higher weight, arterial stiffness and HR. After adjusting for anthropometric characteristics, HR, cardiac output and SVR, the HBP group showed greater Pf and Pb. Then, Pf and Pb characteristics associated with HBP would not be explained by anthropometric or hemodynamic factors. To evaluate wave components and reflection parameters could contribute to improve comprehension and management of HBP states. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  12. Dissonance-based eating disorder program reduces cardiac risk: A preliminary trial.

    PubMed

    Green, Melinda A; Willis, Mary; Fernandez-Kong, Kristen; Reyes, Shuhan; Linkhart, Ruby; Johnson, Molly; Thorne, Tyler; Kroska, Emily; Woodward, Halley; Lindberg, Jessica

    2017-04-01

    We conducted a randomized, controlled preliminary trial to examine the effect of a dissonance-based eating disorder program on eating disorder symptoms and cardiac risk indices in a community sample of women with subclinical and clinical symptoms (N = 47), examining the efficacy of the program in both the indicated prevention and treatment realms. Eating disorder symptoms, body mass index, and biomarkers of cardiac risk were examined in dissonance and assessment-only control conditions at baseline, postintervention, and 2-month follow-up. Specifically, we assessed mean R wave amplitude, QT interval length, vagal tone (high frequency spectral power of heart rate variability), and sympathetic tone (low/high frequency spectral power ratio) via electocardiography (ECG) at each assessment period. We predicted a statistically significant 2 (condition: control, dissonance) × 3 (time: baseline, postintervention, 2-month follow-up) interaction in the mixed factorial MANOVA results. Results confirmed this hypothesis. Eating disorder symptoms and cardiac risk indices decreased significantly among participants in the dissonance condition at postintervention and 2-month follow-up compared with baseline. Results provide support for the efficacy of a dissonance-based program in the reduction of eating disorder symptoms and cardiac risk indices among women with subclinical and clinical eating disorder symptoms. Findings establish the efficaciousness of this dissonance-based approach in the indicated prevention and treatment realms and establish its efficacy in reducing cardiac risk indicators. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  13. A Case of Cardiac Cephalalgia Showing Reversible Coronary Vasospasm on Coronary Angiogram

    PubMed Central

    Yang, YoungSoon; Jin, Dong Gyu; Jang, Il Mi; Jang, YoungHee; Na, Hae Ri; Kim, SanYun

    2010-01-01

    Background Under certain conditions, exertional headaches may reflect coronary ischemia. Case Report A 44-year-old woman developed intermittent exercise-induced headaches with chest tightness over a period of 10 months. Cardiac catheterization followed by acetylcholine provocation demonstrated a right coronary artery spasm with chest tightness, headache, and ischemic effect of continuous electrocardiography changes. The patient's headache disappeared following intra-arterial nitroglycerine injection. Conclusions A coronary angiogram with provocation study revealed variant angina and cardiac cephalalgia, as per the International Classification of Headache Disorders (code 10.6). We report herein a patient with cardiac cephalalgia that manifested as reversible coronary vasospasm following an acetylcholine provocation test. PMID:20607049

  14. Acoustic heart. Interpretation of Phonocardiograms by computer

    NASA Astrophysics Data System (ADS)

    Granados, J.; Tavera, F.; Velázquez, J. M.; López, G.; Hernández, R. T.; Morales, A.

    2015-01-01

    In the field of Cardiology have been identified several heart pathologies associated with problems in valves and narrowing in veins. Each case is associated with a specific sound emitted by the heart, detected in cardiac auscultation. On the Phonocardiogram, sound is visualized as a peak in the wave. In the Optics Laboratory of the Universidad Autonoma Metropolitana - Azcapotzalco, we have developed a simulation of the Phonocardiograms of heart sounds associated with the main pathologies and a computer program of recognition of images that allows you to quickly identify the respective diseases. This is a novel way to analyze Phonocardiograms and the foundation for building a portable non-invasive cardiac diagnostic computerized analyzer system.

  15. Boundary control of bidomain equations with state-dependent switching source functions in the ionic model

    NASA Astrophysics Data System (ADS)

    Chamakuri, Nagaiah; Engwer, Christian; Kunisch, Karl

    2014-09-01

    Optimal control for cardiac electrophysiology based on the bidomain equations in conjunction with the Fenton-Karma ionic model is considered. This generic ventricular model approximates well the restitution properties and spiral wave behavior of more complex ionic models of cardiac action potentials. However, it is challenging due to the appearance of state-dependent discontinuities in the source terms. A computational framework for the numerical realization of optimal control problems is presented. Essential ingredients are a shape calculus based treatment of the sensitivities of the discontinuous source terms and a marching cubes algorithm to track iso-surface of excitation wavefronts. Numerical results exhibit successful defibrillation by applying an optimally controlled extracellular stimulus.

  16. A wearable device for continuous monitoring of heart mechanical function based on impedance cardiography.

    PubMed

    Panfili, G; Piccini, L; Maggi, L; Parini, S; Andreoni, G

    2006-01-01

    In this study we explored the possibility to realize a low power device for Cardiac Output continuous monitoring based on impedance cardiography technique. We assessed the possibility to develop a system able to record data allow an intra-subjective analysis based on the daily variations of this measure. The device was able to acquire and to send signals using a wireless Bluetooth transmission. The electronic circuit was designed in order to minimize power consumption, dimension and weight. The reported results were interesting for what concerns the power consumption and then noise level. In this way was obtained a wearable device that will permit to define specific clinical protocols based on continuous monitoring of the Cardiac Output signal.

  17. Development of a diagnosis- and procedure-based risk model for 30-day outcome after pediatric cardiac surgery.

    PubMed

    Crowe, Sonya; Brown, Kate L; Pagel, Christina; Muthialu, Nagarajan; Cunningham, David; Gibbs, John; Bull, Catherine; Franklin, Rodney; Utley, Martin; Tsang, Victor T

    2013-05-01

    The study objective was to develop a risk model incorporating diagnostic information to adjust for case-mix severity during routine monitoring of outcomes for pediatric cardiac surgery. Data from the Central Cardiac Audit Database for all pediatric cardiac surgery procedures performed in the United Kingdom between 2000 and 2010 were included: 70% for model development and 30% for validation. Units of analysis were 30-day episodes after the first surgical procedure. We used logistic regression for 30-day mortality. Risk factors considered included procedural information based on Central Cardiac Audit Database "specific procedures," diagnostic information defined by 24 "primary" cardiac diagnoses and "univentricular" status, and other patient characteristics. Of the 27,140 30-day episodes in the development set, 25,613 were survivals, 834 were deaths, and 693 were of unknown status (mortality, 3.2%). The risk model includes procedure, cardiac diagnosis, univentricular status, age band (neonate, infant, child), continuous age, continuous weight, presence of non-Down syndrome comorbidity, bypass, and year of operation 2007 or later (because of decreasing mortality). A risk score was calculated for 95% of cases in the validation set (weight missing in 5%). The model discriminated well; the C-index for validation set was 0.77 (0.81 for post-2007 data). Removal of all but procedural information gave a reduced C-index of 0.72. The model performed well across the spectrum of predicted risk, but there was evidence of underestimation of mortality risk in neonates undergoing operation from 2007. The risk model performs well. Diagnostic information added useful discriminatory power. A future application is risk adjustment during routine monitoring of outcomes in the United Kingdom to assist quality assurance. Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  18. Toward continuous-wave operation of organic semiconductor lasers

    PubMed Central

    Sandanayaka, Atula S. D.; Matsushima, Toshinori; Bencheikh, Fatima; Yoshida, Kou; Inoue, Munetomo; Fujihara, Takashi; Goushi, Kenichi; Ribierre, Jean-Charles; Adachi, Chihaya

    2017-01-01

    The demonstration of continuous-wave lasing from organic semiconductor films is highly desirable for practical applications in the areas of spectroscopy, data communication, and sensing, but it still remains a challenging objective. We report low-threshold surface-emitting organic distributed feedback lasers operating in the quasi–continuous-wave regime at 80 MHz as well as under long-pulse photoexcitation of 30 ms. This outstanding performance was achieved using an organic semiconductor thin film with high optical gain, high photoluminescence quantum yield, and no triplet absorption losses at the lasing wavelength combined with a mixed-order distributed feedback grating to achieve a low lasing threshold. A simple encapsulation technique greatly reduced the laser-induced thermal degradation and suppressed the ablation of the gain medium otherwise taking place under intense continuous-wave photoexcitation. Overall, this study provides evidence that the development of a continuous-wave organic semiconductor laser technology is possible via the engineering of the gain medium and the device architecture. PMID:28508042

  19. Toward continuous-wave operation of organic semiconductor lasers.

    PubMed

    Sandanayaka, Atula S D; Matsushima, Toshinori; Bencheikh, Fatima; Yoshida, Kou; Inoue, Munetomo; Fujihara, Takashi; Goushi, Kenichi; Ribierre, Jean-Charles; Adachi, Chihaya

    2017-04-01

    The demonstration of continuous-wave lasing from organic semiconductor films is highly desirable for practical applications in the areas of spectroscopy, data communication, and sensing, but it still remains a challenging objective. We report low-threshold surface-emitting organic distributed feedback lasers operating in the quasi-continuous-wave regime at 80 MHz as well as under long-pulse photoexcitation of 30 ms. This outstanding performance was achieved using an organic semiconductor thin film with high optical gain, high photoluminescence quantum yield, and no triplet absorption losses at the lasing wavelength combined with a mixed-order distributed feedback grating to achieve a low lasing threshold. A simple encapsulation technique greatly reduced the laser-induced thermal degradation and suppressed the ablation of the gain medium otherwise taking place under intense continuous-wave photoexcitation. Overall, this study provides evidence that the development of a continuous-wave organic semiconductor laser technology is possible via the engineering of the gain medium and the device architecture.

  20. Continuous Intraoperative Cefazolin Infusion May Reduce Surgical Site Infections During Cardiac Surgical Procedures: A Propensity-Matched Analysis.

    PubMed

    Trent Magruder, J; Grimm, Joshua C; Dungan, Samuel P; Shah, Ashish S; Crow, Jessica R; Shoulders, Bethany R; Lester, Laeben; Barodka, Viachaslau

    2015-12-01

    The authors sought to determine whether an institutional transition from intermittent to continuous dosing of intraoperative antibiotics in cardiac surgery affected surgical site infection (SSI) outcomes. A retrospective chart review utilizing propensity matching. A single academic, tertiary care hospital. One thousand one hundred seventy-nine patients undergoing coronary artery bypass grafting (CABG) and/or cardiac valvular surgery between April 2013 and November 2014 who received perioperative cefazolin. By method of cefazolin administration, patients were divided into an "intermittent-dosing" (ID) group and a "continuous-infusion" (CI) group. Of the 1,179 patients who underwent cardiac surgery during the study period, 1:1 propensity score matching yielded 399 patients in each group. Rates of diabetes (33.6% ID v 33.8% CI, p = 0.94), coronary artery bypass (62.3% v 61.4%, p = 0.66), and bilateral internal mammary artery harvesting (6.0% v 8.3%, p = 0.22) were similar between groups. SSIs occurred in more ID patients than CI patients (2.3% v 0.5%, p = 0.03). This difference was driven by decreases in extremity and conduit harvest site SSIs (1.8% v 0.3%, p = 0.03), as there were no episodes of mediastinitis, and superficial sternal SSI rates did not differ (0.5% v 0.3%, p = 0.56). There also were significantly fewer episodes of pneumonia in the CI group (6.0% v 2.3%, p = 0.008). Intensive care unit and total lengths of stay did not differ. Thirty-day mortality was 2.8% in both groups (p = 1.00). As compared to ID regimens, CI cefazolin infusion may reduce post-cardiac surgery infectious complications. Further study in larger patient populations is needed. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Effect of Sleep Apnea and Continuous Positive Airway Pressure on Cardiac Structure and Recurrence of Atrial Fibrillation

    PubMed Central

    Neilan, Tomas G.; Farhad, Hoshang; Dodson, John A.; Shah, Ravi V.; Abbasi, Siddique A.; Bakker, Jessie P.; Michaud, Gregory F.; van der Geest, Rob; Blankstein, Ron; Steigner, Michael; John, Roy M.; Jerosch‐Herold, Michael; Malhotra, Atul; Kwong, Raymond Y.

    2013-01-01

    Background Sleep apnea (SA) is associated with an increased risk of atrial fibrillation (AF). We sought to determine the effect of SA on cardiac structure in patients with AF, whether therapy for SA was associated with beneficial cardiac structural remodelling, and whether beneficial cardiac structural remodelling translated into a reduced risk of recurrence of AF after pulmonary venous isolation (PVI). Methods and Results A consecutive group of 720 patients underwent a cardiac magnetic resonance study before PVI. Patients with SA (n=142, 20%) were more likely to be male, diabetic, and hypertensive and have an increased pulmonary artery pressure, right ventricular volume, atrial dimensions, and left ventricular mass. Treated SA was defined as duration of continuous positive airway pressure therapy of >4 hours per night. Treated SA patients (n=71, 50%) were more likely to have paroxysmal AF, a lower blood pressure, lower ventricular mass, and smaller left atrium. During a follow‐up of 42 months, AF recurred in 245 patients. The cumulative incidence of AF recurrence was 51% in patients with SA, 30% in patients without SA, 68% in patients with untreated SA, and 35% in patients with treated SA. In a multivariable model, the presence of SA (hazard ratio 2.79, CI 1.97 to 3.94, P<0.0001) and untreated SA (hazard ratio 1.61, CI 1.35 to 1.92, P<0.0001) were highly associated with AF recurrence. Conclusions Patients with SA have an increased blood pressure, pulmonary artery pressure, right ventricular volume, left atrial size, and left ventricular mass. Therapy with continuous positive airway pressure is associated with lower blood pressure, atrial size, and ventricular mass, and a lower risk of AF recurrence after PVI. PMID:24275628

  2. Morphine Pharmacokinetics in Children With Down Syndrome Following Cardiac Surgery.

    PubMed

    Goot, Benjamin H; Kaufman, Jon; Pan, Zhaoxing; Bourne, David W A; Hickey, Francis; Twite, Mark; Galinkin, Jeffrey; Christians, Uwe; Zuk, Jeannie; da Cruz, Eduardo M

    2018-05-01

    To assess if morphine pharmacokinetics are different in children with Down syndrome when compared with children without Down syndrome. Prospective single-center study including subjects with Down syndrome undergoing cardiac surgery (neonate to 18 yr old) matched by age and cardiac lesion with non-Down syndrome controls. Subjects were placed on a postoperative morphine infusion that was adjusted as clinically necessary, and blood was sampled to measure morphine and its metabolites concentrations. Morphine bolus dosing was used as needed, and total dose was tracked. Infusions were continued for 24 hours or until patients were extubated, whichever came first. Postinfusion, blood samples were continued for 24 hours for further evaluation of kinetics. If patients continued to require opioid, a nonmorphine alternative was used. Morphine concentrations were determined using a unique validated liquid chromatography tandem-mass spectrometry assay using dried blood spotting as opposed to large whole blood samples. Morphine concentration versus time data was modeled using population pharmacokinetics. A 16-bed cardiac ICU at an university-affiliated hospital. Forty-two patients (20 Down syndrome, 22 controls) were enrolled. None. The pharmacokinetics of morphine in pediatric patients with and without Down syndrome following cardiac surgery were analyzed. No significant difference was found in the patient characteristics or variables assessed including morphine total dose or time on infusion. Time mechanically ventilated was longer in children with Down syndrome, and regarding morphine pharmacokinetics, the covariates analyzed were age, weight, presence of Down syndrome, and gender. Only age was found to be significant. This study did not detect a significant difference in morphine pharmacokinetics between Down syndrome and non-Down syndrome children with congenital heart disease.

  3. Classification of cardiac arrhythmias using competitive networks.

    PubMed

    Leite, Cicilia R M; Martin, Daniel L; Sizilio, Glaucia R A; Dos Santos, Keylly E A; de Araujo, Bruno G; Valentim, Ricardo A M; Neto, Adriao D D; de Melo, Jorge D; Guerreiro, Ana M G

    2010-01-01

    Information generated by sensors that collect a patient's vital signals are continuous and unlimited data sequences. Traditionally, this information requires special equipment and programs to monitor them. These programs process and react to the continuous entry of data from different origins. Thus, the purpose of this study is to analyze the data produced by these biomedical devices, in this case the electrocardiogram (ECG). Processing uses a neural classifier, Kohonen competitive neural networks, detecting if the ECG shows any cardiac arrhythmia. In fact, it is possible to classify an ECG signal and thereby detect if it is exhibiting or not any alteration, according to normality.

  4. PDE1C deficiency antagonizes pathological cardiac remodeling and dysfunction

    PubMed Central

    Knight, Walter E.; Chen, Si; Zhang, Yishuai; Oikawa, Masayoshi; Wu, Meiping; Zhou, Qian; Miller, Clint L.; Cai, Yujun; Mickelsen, Deanne M.; Moravec, Christine; Small, Eric M.; Abe, Junichi; Yan, Chen

    2016-01-01

    Cyclic nucleotide phosphodiesterase 1C (PDE1C) represents a major phosphodiesterase activity in human myocardium, but its function in the heart remains unknown. Using genetic and pharmacological approaches, we studied the expression, regulation, function, and underlying mechanisms of PDE1C in the pathogenesis of cardiac remodeling and dysfunction. PDE1C expression is up-regulated in mouse and human failing hearts and is highly expressed in cardiac myocytes but not in fibroblasts. In adult mouse cardiac myocytes, PDE1C deficiency or inhibition attenuated myocyte death and apoptosis, which was largely dependent on cyclic AMP/PKA and PI3K/AKT signaling. PDE1C deficiency also attenuated cardiac myocyte hypertrophy in a PKA-dependent manner. Conditioned medium taken from PDE1C-deficient cardiac myocytes attenuated TGF-β–stimulated cardiac fibroblast activation through a mechanism involving the crosstalk between cardiac myocytes and fibroblasts. In vivo, cardiac remodeling and dysfunction induced by transverse aortic constriction, including myocardial hypertrophy, apoptosis, cardiac fibrosis, and loss of contractile function, were significantly attenuated in PDE1C-knockout mice relative to wild-type mice. These results indicate that PDE1C activation plays a causative role in pathological cardiac remodeling and dysfunction. Given the continued development of highly specific PDE1 inhibitors and the high expression level of PDE1C in the human heart, our findings could have considerable therapeutic significance. PMID:27791092

  5. Watt-Level Continuous-Wave Emission from a Bi-Functional Quantum Cascade Laser/Detector

    DTIC Science & Technology

    2017-04-18

    facet continuous wave emission at 15◦C. Apart from the general performance benets, this enables sensing techiques which rely on continuous wave...record achieved with strained material at this wavelength. Keywords quantum cascade laser, quantum cascade detector, lab- on -a-chip, monolithic integrated...materials, which makes their integration on Si particularly dicult. Heterogeneous integration using transfer techniques allows both single device and wafer

  6. Rotating spiral waves in fertilized ascidian eggs.

    PubMed

    Ballarò, Benedetto; Reas, Pier Giorgio

    2002-01-01

    Excitable systems modelled by reaction-diffusion equation may be expected to produce quite complex spatial patterns. Winfree [1974] demonstrated experimentally, in the Belousov-Zhabotinskii reaction, the existence of particular waves called rotating spiral waves. Later Keener and Tyson [1986] presented a thorough analysis of these waves in excitable systems. Spiral waves can also be observed in brain tissue (Shibata and Bures [1974]), while it seems that the precursor to cardiac fibrillation is the appearance of rotating waves of electrical impulses (Winfree [1983]). In this work we suppose the appearance of Ca++ spiral waves in the vegetal pole of ascidian egg cells after the first ooplasmic segregation. Previously we observed that (Ballarò and Reas [2000a]), when the myoplasm is completely localized in the vegetal region (excitable stage) and the ascidian egg cell is perturbed by an increase of Ca++ concentration in the culture medium, the cell reacts by showing persistent mechanical waves of contraction which exist as long as the cell is perturbed. Experimentally we observed the production of a polar lobe located in the vegetal region and the change of the inclination of mitotic furrow, after the appearance of a myoplasmic spiral wave in the vegetal pole. So we suppose that the myoplasmic spiral wave is due to a Ca++ spiral wave, and the myoplasmic spiral wave then causes the changes in the shape of the cell (polar lobe, inclination of mitotic furrow, etc.). Moreover we give a simple geometrical description of a spiral wave.

  7. Reasons for Trying E-cigarettes and Risk of Continued Use

    PubMed Central

    Kong, Grace; Cavallo, Dana A.; Camenga, Deepa R.; Krishnan-Sarin, Suchitra

    2016-01-01

    BACKGROUND: Longitudinal research is needed to identify predictors of continued electronic cigarette (e-cigarette) use among youth. We expected that certain reasons for first trying e-cigarettes would predict continued use over time (eg, good flavors, friends use), whereas other reasons would not predict continued use (eg, curiosity). METHODS: Longitudinal surveys from middle and high school students from fall 2013 (wave 1) and spring 2014 (wave 2) were used to examine reasons for trying e-cigarettes as predictors of continued e-cigarette use over time. Ever e-cigarette users (n = 340) at wave 1 were categorized into those using or not using e-cigarettes at wave 2. Among those who continued using e-cigarettes, reasons for trying e-cigarettes were examined as predictors of use frequency, measured as the number of days using e-cigarettes in the past 30 days at wave 2. Covariates included age, sex, race, and smoking of traditional cigarettes. RESULTS: Several reasons for first trying e-cigarettes predicted continued use, including low cost, the ability to use e-cigarettes anywhere, and to quit smoking regular cigarettes. Trying e-cigarettes because of low cost also predicted more days of e-cigarette use at wave 2. Being younger or a current smoker of traditional cigarettes also predicted continued use and more frequent use over time. CONCLUSIONS: Regulatory strategies such as increasing cost or prohibiting e-cigarette use in certain places may be important for preventing continued use in youth. In addition, interventions targeting current cigarette smokers and younger students may also be needed. PMID:27503349

  8. Reasons for Trying E-cigarettes and Risk of Continued Use.

    PubMed

    Bold, Krysten W; Kong, Grace; Cavallo, Dana A; Camenga, Deepa R; Krishnan-Sarin, Suchitra

    2016-09-01

    Longitudinal research is needed to identify predictors of continued electronic cigarette (e-cigarette) use among youth. We expected that certain reasons for first trying e-cigarettes would predict continued use over time (eg, good flavors, friends use), whereas other reasons would not predict continued use (eg, curiosity). Longitudinal surveys from middle and high school students from fall 2013 (wave 1) and spring 2014 (wave 2) were used to examine reasons for trying e-cigarettes as predictors of continued e-cigarette use over time. Ever e-cigarette users (n = 340) at wave 1 were categorized into those using or not using e-cigarettes at wave 2. Among those who continued using e-cigarettes, reasons for trying e-cigarettes were examined as predictors of use frequency, measured as the number of days using e-cigarettes in the past 30 days at wave 2. Covariates included age, sex, race, and smoking of traditional cigarettes. Several reasons for first trying e-cigarettes predicted continued use, including low cost, the ability to use e-cigarettes anywhere, and to quit smoking regular cigarettes. Trying e-cigarettes because of low cost also predicted more days of e-cigarette use at wave 2. Being younger or a current smoker of traditional cigarettes also predicted continued use and more frequent use over time. Regulatory strategies such as increasing cost or prohibiting e-cigarette use in certain places may be important for preventing continued use in youth. In addition, interventions targeting current cigarette smokers and younger students may also be needed. Copyright © 2016 by the American Academy of Pediatrics.

  9. The Process of Screening Student-Athletes for Cardiovascular Diseases at NCAA Division I Institutions in the Northeast

    ERIC Educational Resources Information Center

    Blizzard, Ronell

    2010-01-01

    Sudden cardiac death among athletes continues to take the lives of college students across the nation. Leadership at all levels of higher education has great concern over this phenomenon. However, the processes and procedures related to hypertrophic cardiomyopathy (HCM) remain poorly understood. Corrado (1998) suggests that sudden cardiac death of…

  10. Cardiac Catheterization (For Parents)

    MedlinePlus

    ... water, apple juice, and broth). Tell you which medicines your child should continue taking. Discuss the risks and benefits ... when your child can eat and drink continuing medicines your child was on before the procedure or starting new ...

  11. Oscillometric analysis compared with cardiac magnetic resonance for the assessment of aortic pulse wave velocity in patients with myocardial infarction.

    PubMed

    Feistritzer, Hans-Josef; Klug, Gert; Reinstadler, Sebastian J; Reindl, Martin; Mayr, Agnes; Schocke, Michael; Metzler, Bernhard

    2016-09-01

    Measurement of aortic pulse wave velocity (PWV) is the gold standard for assessment of aortic stiffness. In patients with ST-segment elevation myocardial infarction (STEMI), high aortic PWV has deleterious effects on the myocardium. In the present study, we compared a novel oscillometric device with cardiac magnetic resonance (CMR) imaging for the assessment of aortic PWV in STEMI patients. We measured aortic PWV in 60 reperfused STEMI patients using two different methods. The oscillometric method (PWVOSC) is based on mathematical transformation of brachial pressure waveforms, oscillometrically determined using a common cuff (Mobil-O-Graph, I.E.M., Stolberg, North Rhine-Westphalia, Germany). Phase-contrast CMR imaging (1.5 T scanner, Siemens, Erlangen, Bavaria, Germany) at the level of the ascending and abdominal aorta was performed to determine CMR-derived pulse wave velocity with the use of the transit time method. The mean age of the study population was 57 ± 11 years; 11 (18%) were women. Median PWVOSC was 7.4 m/s (interquartile range 6.8-8.9 m/s), and median CMR-derived pulse wave velocity was 6.3 m/s (interquartile range 5.7-8.2 m/s) (P < 0.001). A strong correlation was detected between both methods (r = 0.724, P < 0.001). Bland-Altman analysis revealed a bias of 0.62 m/s (upper and lower limit of agreement: 3.84 and -2.61 m/s). The coefficient of variation between both methods was 21%. In reperfused STEMI patients, aortic PWV assessed noninvasively by transformation of brachial pressure waveforms showed an acceptable agreement with the CMR-derived transit time method.

  12. 3D ultrafast ultrasound imaging in vivo.

    PubMed

    Provost, Jean; Papadacci, Clement; Arango, Juan Esteban; Imbault, Marion; Fink, Mathias; Gennisson, Jean-Luc; Tanter, Mickael; Pernot, Mathieu

    2014-10-07

    Very high frame rate ultrasound imaging has recently allowed for the extension of the applications of echography to new fields of study such as the functional imaging of the brain, cardiac electrophysiology, and the quantitative imaging of the intrinsic mechanical properties of tumors, to name a few, non-invasively and in real time. In this study, we present the first implementation of Ultrafast Ultrasound Imaging in 3D based on the use of either diverging or plane waves emanating from a sparse virtual array located behind the probe. It achieves high contrast and resolution while maintaining imaging rates of thousands of volumes per second. A customized portable ultrasound system was developed to sample 1024 independent channels and to drive a 32  ×  32 matrix-array probe. Its ability to track in 3D transient phenomena occurring in the millisecond range within a single ultrafast acquisition was demonstrated for 3D Shear-Wave Imaging, 3D Ultrafast Doppler Imaging, and, finally, 3D Ultrafast combined Tissue and Flow Doppler Imaging. The propagation of shear waves was tracked in a phantom and used to characterize its stiffness. 3D Ultrafast Doppler was used to obtain 3D maps of Pulsed Doppler, Color Doppler, and Power Doppler quantities in a single acquisition and revealed, at thousands of volumes per second, the complex 3D flow patterns occurring in the ventricles of the human heart during an entire cardiac cycle, as well as the 3D in vivo interaction of blood flow and wall motion during the pulse wave in the carotid at the bifurcation. This study demonstrates the potential of 3D Ultrafast Ultrasound Imaging for the 3D mapping of stiffness, tissue motion, and flow in humans in vivo and promises new clinical applications of ultrasound with reduced intra--and inter-observer variability.

  13. EFFECTS OF CONTINUOUS-WAVE, PULSED, AND SINUSOIDAL-AMPLITUDE-MODULATED MICROWAVES ON BRAIN ENERGY METABOLISM

    EPA Science Inventory

    A comparison of the effects of continuous wave, sinusoidal-amplitude modulated, and pulsed square-wave-modulated 591-MHz microwave exposures on brain energy metabolism was made in male Sprague Dawley rats (175-225g). Brain NADH fluorescence, adensine triphosphate (ATP) concentrat...

  14. Elasticity-based determination of isovolumetric phases in the human heart

    PubMed Central

    2010-01-01

    Background/Motivation To directly determine isovolumetric cardiac time intervals by magnetic resonance elastography (MRE) using the magnitude of the complex signal for deducing morphological information combined with the phase of the complex signal for tension-relaxation measurements. Methods Thirty-five healthy volunteers and 11 patients with relaxation abnormalities were subjected to transthoracic wave stimulation using vibrations of approximately 25 Hz. A k-space-segmented, ECG-gated gradient-recalled echo steady-state sequence with a 500-Hz bipolar motion-encoding gradient was used for acquiring a series of 360 complex images of a short-axis view of the heart at a frame rate of less than 5.2 ms. Magnitude images were employed for measuring the cross-sectional area of the left ventricle, while phase images were used for analyzing the amplitudes of the externally induced waves. The delay between the decrease in amplitude and onset of ventricular contraction was determined in all subjects and assigned to the time of isovolumetric tension. Conversely, the delay between the increase in wave amplitude and ventricular dilatation was used for measuring the time of isovolumetric elasticity relaxation. Results Wave amplitudes decreased during systole and increased during diastole. The variation in wave amplitude occurred ahead of morphological changes. In healthy volunteers the time of isovolumetric elasticity relaxation was 75 ± 31 ms, which is significantly shorter than the time of isovolumetric tension of 136 ± 36 ms (P < 0.01). In patients with relaxation abnormalities (mild diastolic dysfunction, n = 11) isovolumetric elasticity relaxation was significantly prolonged, with 133 ± 57 ms (P < 0.01), whereas isovolumetric tension time was in the range of healthy controls (161 ± 45 ms; P = 0.053). Conclusion The complex MRE signal conveys complementary information on cardiac morphology and elasticity, which can be combined for directly measuring isovolumetric tension and elasticity relaxation in the human heart. PMID:20979648

  15. Elasticity-based determination of isovolumetric phases in the human heart.

    PubMed

    Elgeti, Thomas; Beling, Mark; Hamm, Bernd; Braun, Jürgen; Sack, Ingolf

    2010-10-27

    BACKGROUND/MOTIVATION: To directly determine isovolumetric cardiac time intervals by magnetic resonance elastography (MRE) using the magnitude of the complex signal for deducing morphological information combined with the phase of the complex signal for tension-relaxation measurements. Thirty-five healthy volunteers and 11 patients with relaxation abnormalities were subjected to transthoracic wave stimulation using vibrations of approximately 25 Hz. A k-space-segmented, ECG-gated gradient-recalled echo steady-state sequence with a 500-Hz bipolar motion-encoding gradient was used for acquiring a series of 360 complex images of a short-axis view of the heart at a frame rate of less than 5.2 ms. Magnitude images were employed for measuring the cross-sectional area of the left ventricle, while phase images were used for analyzing the amplitudes of the externally induced waves. The delay between the decrease in amplitude and onset of ventricular contraction was determined in all subjects and assigned to the time of isovolumetric tension. Conversely, the delay between the increase in wave amplitude and ventricular dilatation was used for measuring the time of isovolumetric elasticity relaxation. Wave amplitudes decreased during systole and increased during diastole. The variation in wave amplitude occurred ahead of morphological changes. In healthy volunteers the time of isovolumetric elasticity relaxation was 75 ± 31 ms, which is significantly shorter than the time of isovolumetric tension of 136 ± 36 ms (P < 0.01). In patients with relaxation abnormalities (mild diastolic dysfunction, n = 11) isovolumetric elasticity relaxation was significantly prolonged, with 133 ± 57 ms (P < 0.01), whereas isovolumetric tension time was in the range of healthy controls (161 ± 45 ms; P = 0.053). The complex MRE signal conveys complementary information on cardiac morphology and elasticity, which can be combined for directly measuring isovolumetric tension and elasticity relaxation in the human heart.

  16. Reconstruction of gastric slow wave from finger photoplethysmographic signal using radial basis function neural network.

    PubMed

    Mohamed Yacin, S; Srinivasa Chakravarthy, V; Manivannan, M

    2011-11-01

    Extraction of extra-cardiac information from photoplethysmography (PPG) signal is a challenging research problem with significant clinical applications. In this study, radial basis function neural network (RBFNN) is used to reconstruct the gastric myoelectric activity (GMA) slow wave from finger PPG signal. Finger PPG and GMA (measured using Electrogastrogram, EGG) signals were acquired simultaneously at the sampling rate of 100 Hz from ten healthy subjects. Discrete wavelet transform (DWT) was used to extract slow wave (0-0.1953 Hz) component from the finger PPG signal; this slow wave PPG was used to reconstruct EGG. A RBFNN is trained on signals obtained from six subjects in both fasting and postprandial conditions. The trained network is tested on data obtained from the remaining four subjects. In the earlier study, we have shown the presence of GMA information in finger PPG signal using DWT and cross-correlation method. In this study, we explicitly reconstruct gastric slow wave from finger PPG signal by the proposed RBFNN-based method. It was found that the network-reconstructed slow wave provided significantly higher (P < 0.0001) correlation (≥ 0.9) with the subject's EGG slow wave than the correlation obtained (≈0.7) between the PPG slow wave from DWT and the EEG slow wave. Our results showed that a simple finger PPG signal can be used to reconstruct gastric slow wave using RBFNN method.

  17. Echocardiography as an indication of continuous-time cardiac quiescence

    NASA Astrophysics Data System (ADS)

    Wick, C. A.; Auffermann, W. F.; Shah, A. J.; Inan, O. T.; Bhatti, P. T.; Tridandapani, S.

    2016-07-01

    Cardiac computed tomography (CT) angiography using prospective gating requires that data be acquired during intervals of minimal cardiac motion to obtain diagnostic images of the coronary vessels free of motion artifacts. This work is intended to assess B-mode echocardiography as a continuous-time indication of these quiescent periods to determine if echocardiography can be used as a cost-efficient, non-ionizing modality to develop new prospective gating techniques for cardiac CT. These new prospective gating approaches will not be based on echocardiography itself but on CT-compatible modalities derived from the mechanics of the heart (e.g. seismocardiography and impedance cardiography), unlike the current standard electrocardiogram. To this end, echocardiography and retrospectively-gated CT data were obtained from ten patients with varied cardiac conditions. CT reconstructions were made throughout the cardiac cycle. Motion of the interventricular septum (IVS) was calculated from both echocardiography and CT reconstructions using correlation-based, deviation techniques. The IVS was chosen because it (1) is visible in echocardiography images, whereas the coronary vessels generally are not, and (2) has been shown to be a suitable indicator of cardiac quiescence. Quiescent phases were calculated as the minima of IVS motion and CT volumes were reconstructed for these phases. The diagnostic quality of the CT reconstructions from phases calculated from echocardiography and CT data was graded on a four-point Likert scale by a board-certified radiologist fellowship-trained in cardiothoracic radiology. Using a Wilcoxon signed-rank test, no significant difference in the diagnostic quality of the coronary vessels was found between CT volumes reconstructed from echocardiography- and CT-selected phases. Additionally, there was a correlation of 0.956 between the echocardiography- and CT-selected phases. This initial work suggests that B-mode echocardiography can be used as a tool to develop CT-compatible gating techniques based on modalities derived from cardiac mechanics rather than relying on the ECG alone.

  18. Novel Imaging Method of Continuous Shear Wave by Ultrasonic Color Flow Mapping

    NASA Astrophysics Data System (ADS)

    Yamakoshi, Yoshiki; Yamamoto, Atsushi; Yuminaka, Yasushi

    Shear wave velocity measurement is a promising method in evaluation of tissue stiffness. Several methods have been developed to measure the shear wave velocity, however, it is difficult to obtain quantitative shear wave image in real-time by low cost system. In this paper, a novel shear wave imaging method for continuous shear wave is proposed. This method uses a color flow imaging which is used in ultrasonic imaging system to obtain shear wave's wavefront map. Two conditions, shear wave frequency condition and shear wave displacement amplitude condition, are required, however, these conditions are not severe restrictions in most applications. Using the proposed method, shear wave velocity of trapezius muscle is measured. The result is consistent with the velocity which is calculated from shear elastic modulus measured by ARFI method.

  19. Drosophila as a model to study cardiac aging

    PubMed Central

    Nishimura, Mayuko; Ocorr, Karen; Bodmer, Rolf; Cartry, Jérôme

    2010-01-01

    With age, cardiac performance declines progressively and the risk of heart disease, a primary cause of mortality, rises dramatically. As the elderly population continues to increase, it is critical to gain a better understanding of the genetic influences and modulatory factors that impact cardiac aging. In an attempt to determine the relevance and utility of the Drosophila heart in unraveling the genetic mechanisms underlying cardiac aging, a variety of heart performance assays have recently been developed to quantify Drosophila heart performance that permit the use of the fruit fly to investigate the heart’s decline with age. As for the human heart, Drosophila heart function also deteriorates with age. Notably, with progressive age the incidence of cardiac arrhythmias, myofibrillar disorganization and susceptibility to heart dysfunction and failure all increase significantly. We review here the evidence for an involvement of the insulin-TOR pathway, the KATP channel subunit dSur, the KCNQ potassium channel, as well as Dystrophin and Myosin in fly cardiac aging, and discuss the utility of the Drosophila heart model for cardiac aging studies. PMID:21130861

  20. Cardiac imaging of congenital heart diseases during interventional procedures continues to evolve: Pros and cons of the main techniques.

    PubMed

    Hascoët, Sebastien; Warin-Fresse, Karine; Baruteau, Alban-Elouen; Hadeed, Khaled; Karsenty, Clement; Petit, Jérôme; Guérin, Patrice; Fraisse, Alain; Acar, Philippe

    2016-02-01

    Cardiac catheterization has contributed to the progress made in the management of patients with congenital heart disease (CHD). First, it allowed clarification of the diagnostic assessment of CHD, by offering a better understanding of normal cardiac physiology and the pathophysiology and anatomy of complex malformations. Then, it became an alternative to surgery and a major component of the therapeutic approach for some CHD lesions. Nowadays, techniques have evolved and cardiac catheterization is widely used to percutaneously close intracardiac shunts, to relieve obstructive valvar or vessel lesions, and for transcatheter valve replacement. Accurate imaging is mandatory to guide these procedures. Cardiac imaging during catheterization of CHD must provide accurate images of lesions, surrounding cardiac structures, medical devices and tools used to deliver them. Cardiac imaging has to be 'real-time' with an excellent temporal resolution to ensure 'eyes-hands' synchronization and 'device-target area' accurate positioning. In this comprehensive review, we provide an overview of conventional cardiac imaging tools used in the catheterization laboratory in daily practice, as well as the effect of recent evolution and future imaging modalities. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  1. Design of a Tunable, Room Temperature, Continuous-Wave Terahertz Source and Detector using Silicon Waveguides

    DTIC Science & Technology

    2008-01-30

    that will use conventional diode- or hotomultiplier-tube-based optical detectors , which are xtremely sensitive . . HEATING AND FREE-CARRIER IMITATIONS...CONTRACT NUMBER IN-HOUSE Design of a tunable, room temperature, continuous-wave terahertz source and detector using silicon waveguides 5b. GRANT...B 261Design of a tunable, room temperature, continuous-wave terahertz source and detector using silicon waveguides T. Baehr-Jones,1,* M. Hochberg,1,3

  2. Physiological variation in left atrial transverse orientation does not influence orthogonal P-wave morphology.

    PubMed

    Petersson, Richard; Mosén, Henrik; Steding-Ehrenborg, Katarina; Carlson, Jonas; Faxén, Lisa; Mohtadi, Alan; Platonov, Pyotr G; Holmqvist, Fredrik

    2017-03-01

    It has previously been demonstrated that orthogonal P-wave morphology in healthy athletes does not depend on atrial size, but the possible impact of left atrial orientation on P-wave morphology remains unknown. In this study, we investigated if left atrial transverse orientation affects P-wave morphology in different populations. Forty-seven patients with atrial fibrillation, 21 patients with arrhythmogenic right ventricular cardiomyopathy, 67 healthy athletes, and 56 healthy volunteers were included. All underwent cardiac magnetic resonance imaging or computed tomography and the orientation of the left atrium was determined. All had 12-lead electrocardiographic recordings, which were transformed into orthogonal leads and orthogonal P-wave morphology was obtained. The median left atrial transverse orientation was 87 (83, 91) degrees (lower and upper quartiles) in the total study population. There was no difference in left atrial transverse orientation between individuals with different orthogonal P-wave morphologies. The physiological variation in left atrial orientation was small within as well as between the different populations. There was no difference in left atrial transverse orientation between subjects with type 1 and type 2 P-wave morphology, implying that in this setting the P-wave morphology was more dependent on atrial conduction than orientation. © 2016 Wiley Periodicals, Inc.

  3. Regression analysis and transfer function in estimating the parameters of central pulse waves from brachial pulse wave.

    PubMed

    Chai Rui; Li Si-Man; Xu Li-Sheng; Yao Yang; Hao Li-Ling

    2017-07-01

    This study mainly analyzed the parameters such as ascending branch slope (A_slope), dicrotic notch height (Hn), diastolic area (Ad) and systolic area (As) diastolic blood pressure (DBP), systolic blood pressure (SBP), pulse pressure (PP), subendocardial viability ratio (SEVR), waveform parameter (k), stroke volume (SV), cardiac output (CO) and peripheral resistance (RS) of central pulse wave invasively and non-invasively measured. These parameters extracted from the central pulse wave invasively measured were compared with the parameters measured from the brachial pulse waves by a regression model and a transfer function model. The accuracy of the parameters which were estimated by the regression model and the transfer function model was compared too. Our findings showed that in addition to the k value, the above parameters of the central pulse wave and the brachial pulse wave invasively measured had positive correlation. Both the regression model parameters including A_slope, DBP, SEVR and the transfer function model parameters had good consistency with the parameters invasively measured, and they had the same effect of consistency. The regression equations of the three parameters were expressed by Y'=a+bx. The SBP, PP, SV, CO of central pulse wave could be calculated through the regression model, but their accuracies were worse than that of transfer function model.

  4. INTERDISCIPLINARY PHYSICS AND RELATED AREAS OF SCIENCE AND TECHNOLOGY: Instability and Death of Spiral Wave in a Two-Dimensional Array of Hindmarsh-Rose Neurons

    NASA Astrophysics Data System (ADS)

    Wang, Chun-Ni; Ma, Jun; Tang, Jun; Li, Yan-Long

    2010-02-01

    Spiral wave could be observed in the excitable media, the neurons are often excitable within appropriate parameters. The appearance and formation of spiral wave in the cardiac tissue is linked to monomorphic ventricular tachycardia that can denervate into polymorphic tachycardia and ventricular fibrillation. The neuronal system often consists of a large number of neurons with complex connections. In this paper, we theoretically study the transition from spiral wave to spiral turbulence and homogeneous state (death of spiral wave) in two-dimensional array of the Hindmarsh-Rose neuron with completely nearest-neighbor connections. In our numerical studies, a stable rotating spiral wave is developed and selected as the initial state, then the bifurcation parameters are changed to different values to observe the transition from spiral wave to homogeneous state, breakup of spiral wave and weak change of spiral wave, respectively. A statistical factor of synchronization is defined with the mean field theory to analyze the transition from spiral wave to other spatial states, and the snapshots of the membrane potentials of all neurons and time series of mean membrane potentials of all neurons are also plotted to discuss the change of spiral wave. It is found that the sharp changing points in the curve for factor of synchronization vs. bifurcation parameter indicate sudden transition from spiral wave to other states. And the results are independent of the number of neurons we used.

  5. Freak Waves In The Ocean A~é­ We Need Continuous Measurements!

    NASA Astrophysics Data System (ADS)

    Liu, P.; Teng, C.; Mori, N.

    Freak waves, sometimes also known as rogue waves, are a particular kind of ocean waves that displays a singular, unexpected, and unusually high wave profile with an extraordinarily large and steep trough or crest. The existence of freak waves has be- come widely accepted while it always poses severe hazard to the navy fleets, merchant marines, offshore structures, and virtually all oceanic ventures. Multitudes of seagoing vessels and mariners have encountered freak waves over the years, many had resulted in disasters. The emerging interest in freak waves and the quest to grasp an understand- ing of the phenomenon have inspired numerous theoretical conjectures in recent years. But the practical void of actual field observation on freak waves renders even the well- developed theories remain unverified. Furthermore, the present wave measurement systems, which have been in practice for the last 5 decades, are not at all designed to capture freak waves. We wish therefore to propose and petition to all oceanic scientist and engineers to consider undertaking an unprecedented but technologically feasible practice of making continuous and uninterrupted wave measurements. As freak waves can happen anywhere in the ocean and at anytime, the continuous and uninterrupted measurements at a fixed station would certainly be warranted to document the occur- rence of freak waves, if present, and thus lead to basic realizations of the underlying driving mechanisms.

  6. An update on insertable cardiac monitors: examining the latest clinical evidence and technology for arrhythmia management.

    PubMed

    Olsen, Flemming J; Biering-Sørensen, Tor; Krieger, Derk W

    2015-05-01

    Continuous cardiac rhythm monitoring has undergone compelling progress over the past decades. Cardiac monitoring has emerged from 12-lead electrocardiograms being performed at the discretion of the treating physician to in-hospital telemetry, Holter monitoring, prolonged external event monitoring and most recently toward insertable device monitoring for several years. Significant advantages and disadvantages pertaining to these monitoring options will be addressed in this review. Insertable cardiac monitors have several advantages over external monitoring techniques and may signify a clinical turning point in the field of arrhythmia management. However, their role in the detection of paroxysmal atrial fibrillation after cryptogenic strokes has yet to evolve. This will be the main focus of this review. Issues surrounding patient selection, clinical relevance and determination of cost-effectiveness for prolonged cardiac monitoring require further studies. Furthermore, insertable cardiac monitoring has not only the potential to augment diagnostic capabilities but also to improve the management of paroxysmal atrial fibrillation.

  7. Cardiac troponin T and echocardiographic dimensions after repeated sprint vs. moderate intensity continuous exercise in healthy young males.

    PubMed

    Weippert, Matthias; Divchev, Dimitar; Schmidt, Paul; Gettel, Hannes; Neugebauer, Antina; Behrens, Kristin; Wolfarth, Bernd; Braumann, Klaus-Michael; Nienaber, Christoph A

    2016-04-19

    Regular physical exercise can positively influence cardiac function; however, investigations have shown an increase of myocardial damage biomarkers after acute prolonged endurance exercises. We investigated the effect of repeated sprint vs. moderate long duration exercise on markers of myocardial necrosis, as well as cardiac dimensions and functions. Thirteen healthy males performed two different running sessions (randomized, single blinded cross-over design): 60 minutes moderate intensity continuous training (MCT, at 70% of peak heart rate (HRpeak)) and two series of 12 × 30-second sprints with set recovery periods in-between (RST, at 90% HRpeak). Venous blood samples for cardiac troponin T (cTnT), creatine kinase (CK) and MB isoenzyme (CK-MB) were taken 1 and 4 hours after exercise sessions. After each session electrocardiographic (ECG) and transthoracic echocardiographic (TTE) data were recorded. Results showed that all variables - average heart rate, serum lactate concentration during RST, subjective exertion and cTnT after RST - were significantly higher compared to MCT. CK and CK-MB significantly increased regardless of exercise protocol, while ECG and TTE indicated normal cardiac function. Our results provide evidence that RST contributes significantly to cTnT and CK release. This biomarker increase seems to reflect a physiological rather than a pathological phenomenon in healthy, exercising subjects.

  8. Cardiac troponin T and echocardiographic dimensions after repeated sprint vs. moderate intensity continuous exercise in healthy young males

    PubMed Central

    Weippert, Matthias; Divchev, Dimitar; Schmidt, Paul; Gettel, Hannes; Neugebauer, Antina; Behrens, Kristin; Wolfarth, Bernd; Braumann, Klaus-Michael; Nienaber, Christoph A.

    2016-01-01

    Regular physical exercise can positively influence cardiac function; however, investigations have shown an increase of myocardial damage biomarkers after acute prolonged endurance exercises. We investigated the effect of repeated sprint vs. moderate long duration exercise on markers of myocardial necrosis, as well as cardiac dimensions and functions. Thirteen healthy males performed two different running sessions (randomized, single blinded cross-over design): 60 minutes moderate intensity continuous training (MCT, at 70% of peak heart rate (HRpeak)) and two series of 12 × 30-second sprints with set recovery periods in-between (RST, at 90% HRpeak). Venous blood samples for cardiac troponin T (cTnT), creatine kinase (CK) and MB isoenzyme (CK-MB) were taken 1 and 4 hours after exercise sessions. After each session electrocardiographic (ECG) and transthoracic echocardiographic (TTE) data were recorded. Results showed that all variables - average heart rate, serum lactate concentration during RST, subjective exertion and cTnT after RST - were significantly higher compared to MCT. CK and CK-MB significantly increased regardless of exercise protocol, while ECG and TTE indicated normal cardiac function. Our results provide evidence that RST contributes significantly to cTnT and CK release. This biomarker increase seems to reflect a physiological rather than a pathological phenomenon in healthy, exercising subjects. PMID:27090032

  9. Continuous cardiac troponin I release in Fabry disease.

    PubMed

    Feustel, Andreas; Hahn, Andreas; Schneider, Christian; Sieweke, Nicole; Franzen, Wolfgang; Gündüz, Dursun; Rolfs, Arndt; Tanislav, Christian

    2014-01-01

    Fabry disease (FD) is a rare lysosomal storage disorder also affecting the heart. The aims of this study were to determine the frequency of cardiac troponin I (cTNI) elevation, a sensitive parameter reflecting myocardial damage, in a smaller cohort of FD-patients, and to analyze whether persistent cTNI can be a suitable biomarker to assess cardiac dysfunction in FD. cTNI values were determined at least twice per year in 14 FD-patients (6 males and 8 females) regularly followed-up in our centre. The data were related to other parameters of heart function including cardiac magnetic resonance imaging (cMRI). Three patients (21%) without specific vascular risk factors other than FD had persistent cTNI-elevations (range 0.05-0.71 ng/ml, normal: <0.01). cMRI disclosed late gadolinium enhancement (LGE) in all three individuals with cTNI values ≥0.01, while none of the 11 patients with cTNI <0.01 showed a pathological enhancement (p<0.01). Two subjects with increased cTNI-values underwent coronary angiography, excluding relevant stenoses. A myocardial biopsy performed in one during this procedure demonstrated substantial accumulation of globotriaosylceramide (Gb3) in cardiomyocytes. Continuous cTNI elevation seems to occur in a substantial proportion of patients with FD. The high accordance with LGE, reflecting cardiac dysfunction, suggests that cTNI-elevation can be a useful laboratory parameter for assessing myocardial damage in FD.

  10. Symptoms, diagnoses, and sporting consequences among athletes referred to a Danish sports cardiology clinic.

    PubMed

    Kaiser-Nielsen, L V; Tischer, S G; Prescott, E B; Rasmusen, H K

    2017-01-01

    As the number of recreational athletes performing exercise and participating in competitions at a high-level increases, exercise-induced cardiac symptoms may become a more common problem, not least because recreational athletes often continue high-level exercise programs into advanced ages. We investigated the prevalence of cardiac symptoms and diagnoses among 201 athletes referred for cardiac evaluation at a Sports Cardiology Clinic in Denmark. To our knowledge, this is the first systematic study of athletes referred for suspected cardiac disease. The athletes were all well-trained recreational to elite athletes who participated in various sports with different training loads and a wide age span (13-66 years). All patients were referred by physicians, primarily their general practitioner (38%), and palpitations were the most common cardiac symptom (40%). Cardiac symptoms had a sensitivity of 86% in detecting cardiac disease and a specificity of 13%. Cardiac disease was diagnosed in 44% of the patients, and atrial fibrillation was the most prevalent diagnosis (7.5%). Cardiac diseases with therapeutic- or sports-related consequences for the patients were diagnosed in 28% of the population, but only 1% received a recommendation to avoid high-level sports indefinitely. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Long-term obesity promotes alterations in diastolic function induced by reduction of phospholamban phosphorylation at serine-16 without affecting calcium handling.

    PubMed

    Lima-Leopoldo, Ana Paula; Leopoldo, André S; da Silva, Danielle C T; do Nascimento, André F; de Campos, Dijon H S; Luvizotto, Renata A M; de Deus, Adriana F; Freire, Paula P; Medeiros, Alessandra; Okoshi, Katashi; Cicogna, Antonio C

    2014-09-15

    Few studies have evaluated the relationship between the duration of obesity, cardiac function, and the proteins involved in myocardial calcium (Ca(2+)) handling. We hypothesized that long-term obesity promotes cardiac dysfunction due to a reduction of expression and/or phosphorylation of myocardial Ca(2+)-handling proteins. Thirty-day-old male Wistar rats were distributed into two groups (n = 10 each): control (C; standard diet) and obese (Ob; high-fat diet) for 30 wk. Morphological and histological analyses were assessed. Left ventricular cardiac function was assessed in vivo by echocardiographic evaluation and in vitro by papillary muscle. Cardiac protein expression of sarcoplasmic reticulum (SR) Ca(2+)-ATPase (SERCA2a), calsequestrin, L-type Ca(2+) channel, and phospholamban (PLB), as well as PLB serine-16 phosphorylation (pPLB Ser(16)) and PLB threonine-17 phosphorylation (pPLB Thr(17)) were determined by Western blot. The adiposity index was higher (82%) in Ob rats than in C rats. Obesity promoted cardiac hypertrophy without alterations in interstitial collagen levels. Ob rats had increased endocardial and midwall fractional shortening, posterior wall shortening velocity, and A-wave compared with C rats. Cardiac index, early-to-late diastolic mitral inflow ratio, and isovolumetric relaxation time were lower in Ob than in C. The Ob muscles developed similar baseline data and myocardial responsiveness to increased extracellular Ca(2+). Obesity caused a reduction in cardiac pPLB Ser(16) and the pPLB Ser(16)/PLB ratio in Ob rats. Long-term obesity promotes alterations in diastolic function, most likely due to the reduction of pPLB Ser(16), but does not impair the myocardial Ca(2+) entry and recapture to SR. Copyright © 2014 the American Physiological Society.

  12. Augmented baroreflex heart rate gain after moderate-intensity, dynamic exercise

    NASA Technical Reports Server (NTRS)

    Halliwill, J. R.; Taylor, J. A.; Hartwig, T. D.; Eckberg, D. L.

    1996-01-01

    The occurrence of a sustained vasodilation and hypotension after acute, dynamic exercise suggests that exercise may alter arterial baroreflex mechanisms. Therefore, we assessed systemic hemodynamics, baroreflex regulation of heart rate, and cardiac vagal tone after 60 min of cycling at 60% peak oxygen consumption in 12 healthy, untrained men and women (ages 21-28 yr). We derived sigmoidal carotid-cardiac baroreflex relations by measurement of R-R interval changes induced by ramped, stepwise, R-wave-triggered changes in external neck pressure from 40 to -65 mmHg. We estimated tonic cardiac vagal control with power spectral analysis of R-R interval variability in the respiratory frequency band (0.2-0.3 Hz) during frequency- and tidal volume-controlled breathing. Both mean arterial pressure and total peripheral resistance were reduced postexercise [pressure: from 86 +/- 2 (mean +/- SE) to 81 +/- 2 mmHg; resistance: from 23 +/- 2 to 16 +/- 1 units; both P < 0.05]. Cardiac output was increased postexercise (from 3.9 +/- 0.3 to 5.5 +/- 0.5 l/min, P < 0.05). Both slope and range of the carotid-cardiac baroreflex relation were increased postexercise (slope: from 4.7 +/- 0.7 to 6.1 +/- 0.9 ms/mmHg; range: from 186 +/- 23 to 238 +/- 30 ms, P < 0.05). Respiratory R-R interval variability (cardiac vagal tone) was not changed at any time after exercise, whereas heart rate and plasma norepinephrine levels were elevated. Thus moderate-intensity, dynamic exercise increases heart rate and cardiac output, reduces peripheral vascular resistance, and augments baroreflex responsiveness. Our data suggest that augmented baroreflex heart rate gain restrains rather than contributes to postexercise hypotension, which appears to be mediated predominately by vasodilation.

  13. Minocycline suppresses oxidative stress and attenuates fetal cardiac myocyte apoptosis triggered by in utero cocaine exposure

    PubMed Central

    Sinha-Hikim, Indrani; Shen, Ruoqing; Nzenwa, Ify; Gelfand, Robert; Mahata, Sushil K.

    2015-01-01

    This study investigates the molecular mechanisms by which minocycline, a second generation tetracycline, prevents cardiac myocyte death induced by in utero cocaine exposure. Timed mated pregnant Sprague-Dawley (SD) rats received one of the following treatments twice daily from embryonic (E) day 15–21 (E15–E21): (i) intraperitoneal (IP) injections of saline (control); (ii) IP injections of cocaine (15 mg/kg BW); and (iii) IP injections of cocaine + oral administration of 25 mg/kg BW of minocycline. Pups were killed on postnatal day 15 (P15). Additional pregnant dams received twice daily IP injections of cocaine (from E15–E21) + oral administration of a relatively higher (37.5 mg/kg BW) dose of minocycline. Minocycline treatment continued from E15 until the pups were sacrificed on P15. In utero cocaine exposure resulted in an increase in oxidative stress and fetal cardiac myocyte apoptosis through activation of c-Jun-NH2-terminal kinase (JNK) and p38 mitogen-activated protein kinase (MAPK)-mediated mitochondria-dependent apoptotic pathway. Continued minocycline treatment from E15 through P15 significantly prevented oxidative stress, kinase activation, perturbation of BAX/BCL-2 ratio, cytochrome c release, caspase activation, and attenuated fetal cardiac myocyte apoptosis after prenatal cocaine exposure. These results demonstrate in vivo cardioprotective effects of minocycline in preventing fetal cardiac myocyte death after prenatal cocaine exposure. Given its proven clinical safety and ability to cross the placental barrier and enter into the fetal circulation, minocycline may be an effective therapy for preventing cardiac consequences of in utero cocaine exposure. PMID:21424555

  14. Genesis of the characteristic pulmonary venous pressure waveform as described by the reservoir-wave model

    PubMed Central

    Bouwmeester, J Christopher; Belenkie, Israel; Shrive, Nigel G; Tyberg, John V

    2014-01-01

    Conventional haemodynamic analysis of pulmonary venous and left atrial (LA) pressure waveforms yields substantial forward and backward waves throughout the cardiac cycle; the reservoir wave model provides an alternative analysis with minimal waves during diastole. Pressure and flow in a single pulmonary vein (PV) and the main pulmonary artery (PA) were measured in anaesthetized dogs and the effects of hypoxia and nitric oxide, volume loading, and positive-end expiratory pressure (PEEP) were observed. The reservoir wave model was used to determine the reservoir contribution to PV pressure and flow. Subtracting reservoir pressure and flow resulted in ‘excess’ quantities which were treated as wave-related. Wave intensity analysis of excess pressure and flow quantified the contributions of waves originating upstream (from the PA) and downstream (from the LA and/or left ventricle (LV)). Major features of the characteristic PV waveform are caused by sequential LA and LV contraction and relaxation creating backward compression (i.e. pressure-increasing) waves followed by decompression (i.e. pressure-decreasing) waves. Mitral valve opening is linked to a backwards decompression wave (i.e. diastolic suction). During late systole and early diastole, forward waves originating in the PA are significant. These waves were attenuated less with volume loading and delayed with PEEP. The reservoir wave model shows that the forward and backward waves are negligible during LV diastasis and that the changes in pressure and flow can be accounted for by the discharge of upstream reservoirs. In sharp contrast, conventional analysis posits forward and backward waves such that much of the energy of the forward wave is opposed by the backward wave. PMID:25015922

  15. Electroencephalographic Recordings During Withdrawal of Life-Sustaining Therapy Until 30 Minutes After Declaration of Death.

    PubMed

    Norton, Loretta; Gibson, Raechelle M; Gofton, Teneille; Benson, Carolyn; Dhanani, Sonny; Shemie, Sam D; Hornby, Laura; Ward, Roxanne; Young, G Bryan

    2017-03-01

    The timing of the circulatory determination of death for organ donation presents a medical and ethical challenge. Concerns have been raised about the timing of electrocerebral inactivity in relation to the cessation of circulatory function in organ donation after cardio-circulatory death. Nonprocessed electroencephalographic (EEG) measures have not been characterized and may provide insight into neurological function during this process. We assessed electrocortical data in relation to cardiac function after withdrawal of life-sustaining therapy and in the postmortem period after cardiac arrest for four patients in a Canadian intensive care unit. Subhairline EEG and cardio-circulatory monitoring including electrocardiogram, arterial blood pressure (ABP), and oxygen saturation were captured. Electrocerebral inactivity preceded the cessation of the cardiac rhythm and ABP in three patients. In one patient, single delta wave bursts persisted following the cessation of both the cardiac rhythm and ABP. There was a significant difference in EEG amplitude between the 30-minute period before and the 5-minute period following ABP cessation for the group, but we did not observe any well-defined EEG states following the early cardiac arrest period. In a case series of four patients, EEG inactivity preceded electrocardiogram and ABP inactivity during the dying process in three patients. Further study of the electroencephalogram during the withdrawal of life sustaining therapies will add clarity to medical, ethical, and legal concerns for donation after circulatory determined death.

  16. Electromagnetic interference in cardiac rhythm management devices.

    PubMed

    Sweesy, Mark W; Holland, James L; Smith, Kerry W

    2004-01-01

    Clinicians caring for cardiac device patients with implanted pacemakers or cardioverter defibrillators (ICDs) are frequently asked questions by their patients concerning electromagnetic interference (EMI) sources and the devices. EMI may be radiated or conducted and may be present in many different forms including (but not limited to) radiofrequency waves, microwaves, ionizing radiation, acoustic radiation, static and pulsed magnetic fields, and electric currents. Manufacturers have done an exemplary job of interference protection with device features such as titanium casing, signal filtering, interference rejection circuits, feedthrough capacitors, noise reversion function, and programmable parameters. Nevertheless, EMI remains a real concern and a potential danger. Many factors influence EMI including those which the patient can regulate (eg, distance from and duration of exposure) and some the patient cannot control (eg, intensity of the EMI field, signal frequency). Potential device responses are many and range from simple temporary oversensing to permanent device damage Several of the more common EMI-generating devices and their likely effects on cardiac devices are considered in the medical, home, and daily living and work environments.

  17. Restoration of hemodynamics in apnea struggle phase in association with involuntary breathing movements.

    PubMed

    Palada, Ivan; Bakovic, Darija; Valic, Zoran; Obad, Ante; Ivancev, Vladimir; Eterovic, Davor; Shoemaker, J Kevin; Dujic, Zeljko

    2008-04-30

    Involuntary breathing movements (IBM) that occur in the struggle phase of maximal apneas produce waves of negative intrathoracic pressure. This could augment the venous return, increasing thereby the cardiac output and gas exchange, and release the fresh blood from venous pools of spleen and liver. To test these hypotheses we used photoplethysmography and ultrasound for assessment of hemodynamics and spleen size before, during and after maximal dry apneas at large lung volume in 7 trained divers. During the easy-going phase cardiac output was reduced about 40%, due to reduction in stroke volume and in presence of reduced inferior vena cava venous return, while the spleen contracted for about 60 ml. Towards the end of the struggle phase, in presence of intense IBM, the spleen volume further decreased for about 70 ml, while cardiac output and caval flow almost renormalized. In conclusion, IBM coincide with splenic volume reduction and restoration of hemodynamics, likely facilitating the use of the last oxygen reserves before apnea cessation.

  18. Cardiac auscultation in sports medicine: strategies to improve clinical care.

    PubMed

    Barrett, Michael J; Ayub, Bilal; Martinez, Matthew W

    2012-01-01

    Cardiac auscultation is an important part of the preparticipation physical examination of athletes. Sudden death remains a rare but tragic event among athletes. The most common cause of sudden death among young athletes in the United States continues to be hypertrophic cardiomyopathy, which may or may not present with a typical heart murmur. Many clinicians do not possess sufficient proficiency in recognizing abnormal heart murmurs. New insights in the field of auditory learning suggest that cardiac auscultation is more of a technical skill than an intellectual one. Intensive repetition of abnormal heart murmurs has been shown to improve proficiency in cardiac auscultation markedly. Sample audio files of two important murmurs, i.e., an innocent murmur and hypertrophic cardiomyopathy, are provided online with this review.

  19. Graphene induces spontaneous cardiac differentiation in embryoid bodies

    NASA Astrophysics Data System (ADS)

    Ahadian, Samad; Zhou, Yuanshu; Yamada, Shukuyo; Estili, Mehdi; Liang, Xiaobin; Nakajima, Ken; Shiku, Hitoshi; Matsue, Tomokazu

    2016-03-01

    Graphene was embedded into the structure of mouse embryoid bodies (EBs) using the hanging drop technique. The inclusion of 0.2 mg per mL graphene in the EBs did not affect the viability of the stem cells. However, the graphene decreased the stem cell proliferation, probably by accelerating cell differentiation. The graphene also enhanced the mechanical properties and electrical conductivity of the EBs. Interestingly, the cardiac differentiation of the EB-graphene was significantly greater than that of the EBs at day 5 of culture, as confirmed by high-throughput gene analysis. Electrical stimulation (voltage, 4 V; frequency, 1 Hz; and duration, 10 ms for 2 continuous days) further enhanced the cardiac differentiation of the EBs, as demonstrated by analyses of the cardiac protein and gene expression and the beating activity of the EBs. Taken together, the results demonstrated that graphene played a major role in directing the cardiac differentiation of EBs, which has potential cell therapy and tissue regeneration applications.Graphene was embedded into the structure of mouse embryoid bodies (EBs) using the hanging drop technique. The inclusion of 0.2 mg per mL graphene in the EBs did not affect the viability of the stem cells. However, the graphene decreased the stem cell proliferation, probably by accelerating cell differentiation. The graphene also enhanced the mechanical properties and electrical conductivity of the EBs. Interestingly, the cardiac differentiation of the EB-graphene was significantly greater than that of the EBs at day 5 of culture, as confirmed by high-throughput gene analysis. Electrical stimulation (voltage, 4 V; frequency, 1 Hz; and duration, 10 ms for 2 continuous days) further enhanced the cardiac differentiation of the EBs, as demonstrated by analyses of the cardiac protein and gene expression and the beating activity of the EBs. Taken together, the results demonstrated that graphene played a major role in directing the cardiac differentiation of EBs, which has potential cell therapy and tissue regeneration applications. Electronic supplementary information (ESI) available: Fig. S1-S3, Tables S1-S4, and Movies S1-S4. See DOI: 10.1039/c5nr07059g

  20. Fluctuations uncover a distinct class of traveling waves

    PubMed Central

    Korolev, Kirill S.

    2018-01-01

    Epidemics, flame propagation, and cardiac rhythms are classic examples of reaction–diffusion waves that describe a switch from one alternative state to another. Only two types of waves are known: pulled, driven by the leading edge, and pushed, driven by the bulk of the wave. Here, we report a distinct class of semipushed waves for which both the bulk and the leading edge contribute to the dynamics. These hybrid waves have the kinetics of pushed waves, but exhibit giant fluctuations similar to pulled waves. The transitions between pulled, semipushed, and fully pushed waves occur at universal ratios of the wave velocity to the Fisher velocity. We derive these results in the context of a species invading a new habitat by examining front diffusion, rate of diversity loss, and fluctuation-induced corrections to the expansion velocity. All three quantities decrease as a power law of the population density with the same exponent. We analytically calculate this exponent, taking into account the fluctuations in the shape of the wave front. For fully pushed waves, the exponent is −1, consistent with the central limit theorem. In semipushed waves, however, the fluctuations average out much more slowly, and the exponent approaches 0 toward the transition to pulled waves. As a result, a rapid loss of genetic diversity and large fluctuations in the position of the front occur, even for populations with cooperative growth and other forms of an Allee effect. The evolutionary outcome of spatial spreading in such populations could therefore be less predictable than previously thought. PMID:29610340

  1. Fluctuations uncover a distinct class of traveling waves.

    PubMed

    Birzu, Gabriel; Hallatschek, Oskar; Korolev, Kirill S

    2018-04-17

    Epidemics, flame propagation, and cardiac rhythms are classic examples of reaction-diffusion waves that describe a switch from one alternative state to another. Only two types of waves are known: pulled, driven by the leading edge, and pushed, driven by the bulk of the wave. Here, we report a distinct class of semipushed waves for which both the bulk and the leading edge contribute to the dynamics. These hybrid waves have the kinetics of pushed waves, but exhibit giant fluctuations similar to pulled waves. The transitions between pulled, semipushed, and fully pushed waves occur at universal ratios of the wave velocity to the Fisher velocity. We derive these results in the context of a species invading a new habitat by examining front diffusion, rate of diversity loss, and fluctuation-induced corrections to the expansion velocity. All three quantities decrease as a power law of the population density with the same exponent. We analytically calculate this exponent, taking into account the fluctuations in the shape of the wave front. For fully pushed waves, the exponent is -1, consistent with the central limit theorem. In semipushed waves, however, the fluctuations average out much more slowly, and the exponent approaches 0 toward the transition to pulled waves. As a result, a rapid loss of genetic diversity and large fluctuations in the position of the front occur, even for populations with cooperative growth and other forms of an Allee effect. The evolutionary outcome of spatial spreading in such populations could therefore be less predictable than previously thought. Copyright © 2018 the Author(s). Published by PNAS.

  2. Exercises in anatomy: the normal heart.

    PubMed

    Anderson, Robert H; Sarwark, Anne; Spicer, Diane E; Backer, Carl L

    2014-01-01

    In this series of videoclips, we analyze the anatomy of the normal heart. We begin our overview by emphasizing the need, in the current era, to describe the heart in attitudinally appropriate fashion. Increasingly, clinicians are demonstrating the features of the heart as it is located within the body. It is no longer satisfactory, therefore, to describe these components in a ‘Valentine’ fashion, as continues to be the case in most textbooks of normal or cardiac anatomy. We then emphasize the importance of the so-called morphological method, which states that structures within the heart should be defined on the basis of their own intrinsic morphology, and not according to other parts, which are themselves variable. We continue by using this concept to show how the appendages serve to distinguish between the atrial chambers, while the apical trabecular components provide the features to distinguish the ventricles. We then return to the cardiac chambers, emphasizing features of surgical significance, in particular the locations of the cardiac conduction tissues. We proceed by examining the cardiac valves, and conclude by providing a detailed analysis of the septal structures. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  3. Inward rectifier potassium channels control rotor frequency in ventricular fibrillation.

    PubMed

    Jalife, José

    2009-11-01

    Ventricular fibrillation (VF) is the most important cause of sudden cardiac death. While traditionally thought to result from random activation of the ventricles by multiple independent wavelets, recent evidence suggests that VF may be determined by the sustained activation of a relatively small number of reentrant sources. In addition, recent experimental data in various species as well as computer simulations have provided important clues about its ionic and molecular mechanisms, particularly in regards to the role of potassium currents in such mechanisms. The results strongly argue that the inward rectifier current, I(K1,) is an important current during functional reentry because it mediates the electrotonic interactions between the unexcited core and its immediate surroundings. In addition, I(K1) is a stabilizer of reentry due to its ability to shorten action potential duration and reduce conduction velocity near the center of rotation. Increased I(K1) prevents wave front-wave tail interactions and thus averts rotor destabilization and breakup. Other studies have shown that while the slow component of the delayed rectifier potassium current I(Ks) does not significantly modify rotor frequency or stability, it plays a major role in postrepolarization refractoriness and wave break formation. Therefore, the interplay between I(K1) and the rapid sodium inward current (I(Na)) is a major factor in the control of cardiac excitability and thus the stability and frequency of reentry, while I(Ks) is an important determinant of fibrillatory conduction.

  4. A Clinical Feasibility Study of Atrial and Ventricular Electromechanical Wave Imaging

    PubMed Central

    Provost, Jean; Gambhir, Alok; Vest, John; Garan, Hasan; Konofagou, Elisa E.

    2014-01-01

    Background Cardiac Resynchronization Therapy (CRT) and atrial ablation currently lack a noninvasive imaging modality for reliable treatment planning and monitoring. Electromechanical Wave Imaging (EWI) is an ultrasound-based method that has previously been shown to be capable of noninvasively and transmurally mapping the activation sequence of the heart in animal studies by estimating and imaging the electromechanical wave, i.e., the transient strains occurring in response to the electrical activation, at both very high temporal and spatial resolution. Objective Demonstrate the feasibility of noninvasive transthoracic EWI for mapping the activation sequence during different cardiac rhythms in humans. Methods EWI was performed in CRT patients with a left bundle-branch block (LBBB), during sinus rhythm, left-ventricular pacing, and right-ventricular pacing and in atrial flutter (AFL) patients before intervention and correlated with results from invasive intracardiac electrical mapping studies during intervention. Additionally, the feasibility of single-heartbeat EWI at 2000 frames/s, is demonstrated in humans for the first time in a subject with both AFL and right bundle-branch-block. Results The electromechanical activation maps demonstrated the capability of EWI to localize the pacing sites and characterize the LBBB activation sequence transmurally in CRT patients. In AFL patients, the propagation patterns obtained with EWI were in agreement with results obtained from invasive intracardiac mapping studies. Conclusion Our findings demonstrate the potential capability of EWI to aid in monitoring and follow-up of patients undergoing CRT pacing therapy and atrial ablation with preliminary validation in vivo. PMID:23454060

  5. Contrast agent-free sonoporation: The use of an ultrasonic standing wave microfluidic system for the delivery of pharmaceutical agents

    PubMed Central

    Carugo, Dario; Ankrett, Dyan N.; Glynne-Jones, Peter; Capretto, Lorenzo; Boltryk, Rosemary J.; Zhang, Xunli; Townsend, Paul A.; Hill, Martyn

    2011-01-01

    Sonoporation is a useful biophysical mechanism for facilitating the transmembrane delivery of therapeutic agents from the extracellular to the intracellular milieu. Conventionally, sonoporation is carried out in the presence of ultrasound contrast agents, which are known to greatly enhance transient poration of biological cell membranes. However, in vivo contrast agents have been observed to induce capillary rupture and haemorrhage due to endothelial cell damage and to greatly increase the potential for cell lysis in vitro. Here, we demonstrate sonoporation of cardiac myoblasts in the absence of contrast agent (CA-free sonoporation) using a low-cost ultrasound-microfluidic device. Within this device an ultrasonic standing wave was generated, allowing control over the position of the cells and the strength of the acoustic radiation forces. Real-time single-cell analysis and retrospective post-sonication analysis of insonated cardiac myoblasts showed that CA-free sonoporation induced transmembrane transfer of fluorescent probes (CMFDA and FITC-dextran) and that different mechanisms potentially contribute to membrane poration in the presence of an ultrasonic wave. Additionally, to the best of our knowledge, we have shown for the first time that sonoporation induces increased cell cytotoxicity as a consequence of CA-free ultrasound-facilitated uptake of pharmaceutical agents (doxorubicin, luteolin, and apigenin). The US-microfluidic device designed here provides an in vitro alternative to expensive and controversial in vivo models used for early stage drug discovery, and drug delivery programs and toxicity measurements. PMID:22662060

  6. Left ventricle changes early after breath-holding in deep water in elite apnea divers.

    PubMed

    Pingitore, Alessandro; Gemignani, Angelo; Menicucci, Danilo; Passera, Mirko; Frassi, Francesca; Marabotti, Claudio; Piarulli, Andrea; Benassi, Antonio; L'Abbate, Antonio; Bedini, Remo

    2010-01-01

    To study by ultrasounds cardiac morphology and function early after breath-hold diving in deep water in elite athletes. Fifteen healthy male divers (age 28 +/- 3 years) were studied using Doppler-echocardiography, immediately before (basal condition, BC) and two minutes after breath-hold diving (40 meters, acute post-apnea condition, APAC). Each subject performed a series of three consecutive breath-hold dives (20-30 and 40 m depth). End-diastolic left ventricular (LV) diameter (EDD) and end-diastolic LV volume (EDV) increased significantly (p < 0.01). Stroke volume (SV), cardiac index (CI), septal and posterior systolic wall-thickening (SWT) also significantly increased after diving (p < 0.01). No wall motion abnormalities were detected, and wall motion score index was unchanged between BC and APAC. Doppler mitral E wave increased significantly (p < 0.01), whereas the A wave was unchanged. Systemic vascular resistance (SVR) decreased significantly after diving (p < 0.05). In the factor analysis, filtering out the absolute values smaller than 0.7 in the loading matrix, it resulted that factor I consists of EDV, posterior SWT, SV and CI, factor II of diastolic blood pressure, waves A and E and factor III of heart rate and SVR. Systo-diastolic functions were improved in the early period after deep breath-hold diving due to favorable changes in loading conditions relative to pre-diving, namely the recruitment of left ventricular preload reserve and the reduction in afterload.

  7. Bi-directional ultrasonic wave coupling to FBGs in continuously bonded optical fiber sensing.

    PubMed

    Wee, Junghyun; Hackney, Drew; Bradford, Philip; Peters, Kara

    2017-09-01

    Fiber Bragg grating (FBG) sensors are typically spot-bonded onto the surface of a structure to detect ultrasonic waves in laboratory demonstrations. However, to protect the rest of the optical fiber from any environmental damage during real applications, bonding the entire length of fiber, called continuous bonding, is commonly done. In this paper, we investigate the impact of continuously bonding FBGs on the measured Lamb wave signal. In theory, the ultrasonic wave signal can bi-directionally transfer between the optical fiber and the plate at any adhered location, which could potentially produce output signal distortion for the continuous bonding case. Therefore, an experiment is performed to investigate the plate-to-fiber and fiber-to-plate signal transfer, from which the signal coupling coefficient of each case is theoretically estimated based on the experimental data. We demonstrate that the two coupling coefficients are comparable, with the plate-to-fiber case approximately 19% larger than the fiber-to-plate case. Finally, the signal waveform and arrival time of the output FBG responses are compared between the continuous and spot bonding cases. The results indicate that the resulting Lamb wave signal output is only that directly detected at the FBG location; however, a slight difference in signal waveform is observed between the two bonding configurations. This paper demonstrates the practicality of using continuously bonded FBGs for ultrasonic wave detection in structural health monitoring (SHM) applications.

  8. Continuous Wavelet Transform Analysis of Acceleration Signals Measured from a Wave Buoy

    PubMed Central

    Chuang, Laurence Zsu-Hsin; Wu, Li-Chung; Wang, Jong-Hao

    2013-01-01

    Accelerometers, which can be installed inside a floating platform on the sea, are among the most commonly used sensors for operational ocean wave measurements. To examine the non-stationary features of ocean waves, this study was conducted to derive a wavelet spectrum of ocean waves and to synthesize sea surface elevations from vertical acceleration signals of a wave buoy through the continuous wavelet transform theory. The short-time wave features can be revealed by simultaneously examining the wavelet spectrum and the synthetic sea surface elevations. The in situ wave signals were applied to verify the practicality of the wavelet-based algorithm. We confirm that the spectral leakage and the noise at very-low-frequency bins influenced the accuracies of the estimated wavelet spectrum and the synthetic sea surface elevations. The appropriate thresholds of these two factors were explored. To study the short-time wave features from the wave records, the acceleration signals recorded from an accelerometer inside a discus wave buoy are analysed. The results from the wavelet spectrum show the evidence of short-time nonlinear wave events. Our study also reveals that more surface profiles with higher vertical asymmetry can be found from short-time nonlinear wave with stronger harmonic spectral peak. Finally, we conclude that the algorithms of continuous wavelet transform are practical for revealing the short-time wave features of the buoy acceleration signals. PMID:23966188

  9. Novel anisotropic engineered cardiac tissues: studies of electrical propagation.

    PubMed

    Bursac, Nenad; Loo, Yihua; Leong, Kam; Tung, Leslie

    2007-10-05

    The goal of this study was to engineer cardiac tissue constructs with uniformly anisotropic architecture, and to evaluate their electrical function using multi-site optical mapping of cell membrane potentials. Anisotropic polymer scaffolds made by leaching of aligned sucrose templates were seeded with neonatal rat cardiac cells and cultured in rotating bioreactors for 6-14 days. Cells aligned and interconnected inside the scaffolds and when stimulated by a point electrode, supported macroscopically continuous, anisotropic impulse propagation. By culture day 14, the ratio of conduction velocities along vs. across cardiac fibers reached a value of 2, similar to that in native neonatal ventricles, while action potential duration and maximum capture rate, respectively, decreased to 120ms and increased to approximately 5Hz. The shorter culture time and larger scaffold thickness were associated with increased incidence of sustained reentrant arrhythmias. In summary, this study is the first successful attempt to engineer a cm(2)-size, functional anisotropic cardiac tissue patch.

  10. Emerging Cardiac Imaging Modalities for the Early Detection of Cardiotoxicity Due to Anticancer Therapies.

    PubMed

    López-Fernández, Teresa; Thavendiranathan, Paaladinesh

    2017-06-01

    The undeniable advances in the field of oncology have finally led to a decrease in overall cancer-related mortality. However, this population of long-term cancer survivors is now facing a shift toward a substantial increase in cardiovascular morbidity and mortality. Because the development of overt cardiotoxicity can be associated with poor outcomes, preclinical identification of cardiac toxicity is important. This will promote early instauration of treatments to prevent overt heart dysfunction and allow oncologists to continue cancer therapy in an uninterrupted manner. Surveillance strategies for the early detection of cardiac injury include cardiac imaging and biomarkers during treatment. In this review, we outline existing cardiac imaging modalities to detect myocardial changes in patients undergoing cancer treatment and in survivors, and their strengths and limitations. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  11. Addressing Common Questions Encountered in the Diagnosis and Management of Cardiac Amyloidosis

    PubMed Central

    Maurer, Mathew S.; Elliott, Perry; Comenzo, Raymond; Semigran, Marc; Rapezzi, Claudio

    2017-01-01

    Advances in cardiac imaging have resulted in greater recognition of cardiac amyloidosis (CA) in everyday clinical practice, but the diagnosis continues to be made in patients with late stage disease, suggesting that more needs to be done to improve awareness of its clinical manifestations and the potential of therapeutic intervention to improve prognosis. Light chain CA (AL-CA) in particular, if recognized early and treated with targeted plasma cell therapy, can be managed very effectively. For patients with transthyretin amyloidosis, there are numerous therapies that are currently in late phase clinical trials. In this review we address common questions encountered in clinical practice regarding etiology, clinical presentation, diagnosis and management of cardiac amyloidosis, focusing on recent important developments in cardiac imaging and biochemical diagnosis. The aim is to show how a systematic approach to the evaluation of suspected CA can impact the prognosis of patients in the modern era. PMID:28373528

  12. The reservoir-wave approach to characterize pulmonary vascular-right ventricular interactions in humans.

    PubMed

    Ghimire, Anukul; Andersen, Mads J; Burrowes, Lindsay M; Bouwmeester, J Christopher; Grant, Andrew D; Belenkie, Israel; Fine, Nowell M; Borlaug, Barry A; Tyberg, John V

    2016-12-01

    Using the reservoir-wave approach (RWA) we previously characterized pulmonary vasculature mechanics in a normal canine model. We found reflected backward-traveling waves that decrease pressure and increase flow in the proximal pulmonary artery (PA). These waves decrease right ventricular (RV) afterload and facilitate RV ejection. With pathological alterations to the pulmonary vasculature, these waves may change and impact RV performance. Our objective in this study was to characterize PA wave reflection and the alterations in RV performance in cardiac patients, using the RWA. PA pressure, Doppler-flow velocity, and pulmonary arterial wedge pressure were measured in 11 patients with exertional dyspnea. The RWA was employed to analyze PA pressure and flow; wave intensity analysis characterized PA waves. Wave-related pressure was partitioned into two components: pressures due to forward-traveling and to backward-traveling waves. RV performance was assessed by examining the work done in raising reservoir pressure and that associated with the wave components of systolic PA pressure. Wave-related work, the mostly nonrecoverable energy expended by the RV to eject blood, tended to vary directly with mean PA pressure. Where PA pressures were lower, there were pressure-decreasing/flow-increasing backward waves that aided RV ejection. Where PA pressures were higher, there were pressure-increasing/flow-decreasing backward waves that impeded RV ejection. Pressure-increasing/flow-decreasing backward waves were responsible for systolic notches in the Doppler flow velocity profiles in patients with the highest PA pressure. Pulmonary hypertension is characterized by reflected waves that impede RV ejection and an increase in wave-related work. The RWA may facilitate the development of therapeutic strategies. Copyright © 2016 the American Physiological Society.

  13. A Wave-Optics Approach to Paraxial Geometrical Laws Based on Continuity at Boundaries

    ERIC Educational Resources Information Center

    Linares, J.; Nistal, M. C.

    2011-01-01

    We present a derivation of the paraxial geometrical laws starting from a wave-optics approach, in particular by using simple continuity conditions of paraxial spherical waves at boundaries (discontinuities) between optical media. Paraxial geometrical imaging and magnification laws, under refraction and reflection at boundaries, are derived for…

  14. Development of Extracorporeal Shock Wave Therapy for the Treatment for Ischemic Cardiovascular Diseases

    NASA Astrophysics Data System (ADS)

    Shimokawa, Hiroaki

    Cardiovascular diseases, such as coronary artery disease and peripheral artery disease, are the major causes of death in developed countries, and the number of elderly patients has been rapidly increasing worldwide. Thus, it is crucial to develop new non-invasive therapeutic strategies for these patients. We found that a low-energy shock wave (SW) (about 10% of the energy density that is used for urolithiasis) effectively increases the expression of vascular endothelial growth factor (VEGF) in cultured endothelial cells. Subsequently, we demonstrated that extracorporeal cardiac SW therapy with low-energy SW up-regulates the expression of VEGF, enhances angiogenesis, and improves myocardial ischemia in a pig model of chronic myocardial ischemia without any adverse effects in vivo. Based on these promising results in animal studies, we have subsequently developed a new, non-invasive angiogenic therapy with low-energy SW for cardiovascular diseases. Our extracorporeal cardiac SW therapy improved symptoms and myocardial perfusion evaluated with stress-scintigraphy in patients with severe coronary artery disease without indication of percutaneous coronary intervention or coronary artery bypass surgery. Importantly, no procedural complications or adverse effects were noted. The SW therapy was also effective in ameliorating left ventricular remodeling after acute myocardial infarction in pigs and in enhancing angiogenesis in hindlimb ischemia in animals and patients with coronary artery disease. Furthermore, our recent experimental studies suggest that the SW therapy is also effective for indications other than cardiovascular diseases. Thus, our extracorporeal cardiac SW therapy is an effective, safe, and non-invasive angiogenic strategy for cardiovascular medicine.

  15. Estimation of Pulse Transit Time as a Function of Blood Pressure Using a Nonlinear Arterial Tube-Load Model.

    PubMed

    Gao, Mingwu; Cheng, Hao-Min; Sung, Shih-Hsien; Chen, Chen-Huan; Olivier, Nicholas Bari; Mukkamala, Ramakrishna

    2017-07-01

    pulse transit time (PTT) varies with blood pressure (BP) throughout the cardiac cycle, yet, because of wave reflection, only one PTT value at the diastolic BP level is conventionally estimated from proximal and distal BP waveforms. The objective was to establish a technique to estimate multiple PTT values at different BP levels in the cardiac cycle. a technique was developed for estimating PTT as a function of BP (to indicate the PTT value for every BP level) from proximal and distal BP waveforms. First, a mathematical transformation from one waveform to the other is defined in terms of the parameters of a nonlinear arterial tube-load model accounting for BP-dependent arterial compliance and wave reflection. Then, the parameters are estimated by optimally fitting the waveforms to each other via the model-based transformation. Finally, PTT as a function of BP is specified by the parameters. The technique was assessed in animals and patients in several ways including the ability of its estimated PTT-BP function to serve as a subject-specific curve for calibrating PTT to BP. the calibration curve derived by the technique during a baseline period yielded bias and precision errors in mean BP of 5.1 ± 0.9 and 6.6 ± 1.0 mmHg, respectively, during hemodynamic interventions that varied mean BP widely. the new technique may permit, for the first time, estimation of PTT values throughout the cardiac cycle from proximal and distal waveforms. the technique could potentially be applied to improve arterial stiffness monitoring and help realize cuff-less BP monitoring.

  16. Assessment of Time and Frequency Domain Parameters of Heart Rate Variability and Interictal Cardiac Rhythm Abnormalities in Drug-naïve Patients with Idiopathic Generalized Epilepsy.

    PubMed

    Kilinc, Ozden; Cincin, Altug; Pehlivan, Aslihan; Midi, Ipek; Kepez, Alper; Agan, Kadriye

    2016-06-01

    Epilepsy is a disease known to occur with autonomous phenomenons. Earlier studies indicate decreased heart rate variability (HRV) during ictal and interictal periods among epilepsy patients. In this study, we aim to investigate cardiac rhythm abnormalities and HRV during interictal period between drug-naïve patients with idiopathic generalized epilepsy (IGE) and healthy control group. Twenty-six patients with IGE and 26 healthy individuals included in the study. In order to eliminate any structural cardiac pathology, transthoracic echocardiography was performed in all subjects and time and frequency domain parameters of HRV were evaluated after 24-hour rhythm holter monitoring. Between two groups, no significant difference was detected in terms of mean heart rate and maximum duration between the start of the Q waves and the end of the T waves (QT intervals). In the time domain analysis of HRV, no statically significant difference was detected for standard deviation of all R - R intervals and root-mean-square of successive differences between patient and control group (p = 0,070 and p = 0,104 respectively). In the frequency domain analysis of HRV, patients tended to display lower total power and very low frequency power than did healthy subjects, but the differences were not statistically significant. Our results suggest that there is no major effect of the epilepsy on HRV in patients with IGE. It should be emphasized that, in this study, HRV was evaluated only in patients with IGE and that the results are not proper to be generalized for patients with partial seizures.

  17. LONG-TERM MECHANICAL CIRCULATORY SUPPORT (DESTINATION THERAPY): ON TRACK TO COMPETE WITH HEART TRANSPLANTATIO?

    PubMed Central

    Kirklin, James K.; Naftel, David C.; Pagani, Francis D.; Kormos, Robert L.; Stevenson, Lynne; Miller, Marissa; Young, James B.

    2012-01-01

    Objective(s) Average two-year survival following cardiac transplantation is approximately 80%. The evolution and subsequent approval of larger pulsatile and, more recently, continuous flow mechanical circulatory support (MCS) technology for destination therapy (DT) offers the potential for triage of some patients awaiting cardiac transplantation to DT. Methods The National Heart, Lung and Blood Institute Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) is a national multi-institutional study of chronic mechanical circulatory support. Between June 2006 and December 2011, 127 pulsatile and 1160 continuous flow pumps (24% of total primary LVADs) carried an initial strategy of DT therapy. Results By multivariable analysis, risk factors (p<0.05) for mortality following DT included older age, larger body mass index, history of cancer, history of cardiac surgery, INTERMACS level I (cardiogenic shock), dialysis, increased BUN, use of a pulsatile flow device and use of a RVAD. Among continuous flow LVAD patients who were not in cardiogenic shock, a particularly favorable survival was associated with no cancer, patients not in cardiogenic shock, and BUN < 50, resulting in one and two year survival of 88 and 80%. Conclusions 1) Evolution from pulsatile to continuous flow technology has dramatically improved one and two year survival; 2) Destination Therapy is not appropriate for patients with rapid hemodynamic deterioration; or severe right ventricular failure 4) Important subsets of continuous flow DT patients now enjoy survival which is competitive with heart transplantation out to about two years. PMID:22795459

  18. Penetration of magnetosonic waves into the plasmasphere observed by the Van Allen Probes

    DOE PAGES

    Xiao, Fuliang; Zhou, Qinghua; He, Yihua; ...

    2015-09-11

    During the small storm on 14–15 April 2014, Van Allen Probe A measured a continuously distinct proton ring distribution and enhanced magnetosonic (MS) waves along its orbit outside the plasmapause. Inside the plasmasphere, strong MS waves were still present but the distinct proton ring distribution was falling steeply with distance. We adopt a sum of subtracted bi-Maxwellian components to model the observed proton ring distribution and simulate the wave trajectory and growth. MS waves at first propagate toward lower L shells outside the plasmasphere, with rapidly increasing path gains related to the continuous proton ring distribution. The waves then graduallymore » cross the plasmapause into the deep plasmasphere, with almost unchanged path gains due to the falling proton ring distribution and higher ambient density. These results present the first report on how MS waves penetrate into the plasmasphere with the aid of the continuous proton ring distributions during weak geomagnetic activities.« less

  19. Directed search for continuous gravitational waves from the Galactic center

    NASA Astrophysics Data System (ADS)

    Aasi, J.; Abadie, J.; Abbott, B. P.; Abbott, R.; Abbott, T.; Abernathy, M. R.; Accadia, T.; Acernese, F.; Adams, C.; Adams, T.; Adhikari, R. X.; Affeldt, C.; Agathos, M.; Aggarwal, N.; Aguiar, O. D.; Ajith, P.; Allen, B.; Allocca, A.; Amador Ceron, E.; Amariutei, D.; Anderson, R. A.; Anderson, S. B.; Anderson, W. G.; Arai, K.; Araya, M. C.; Arceneaux, C.; Areeda, J.; Ast, S.; Aston, S. M.; Astone, P.; Aufmuth, P.; Aulbert, C.; Austin, L.; Aylott, B. E.; Babak, S.; Baker, P. T.; Ballardin, G.; Ballmer, S. W.; Barayoga, J. C.; Barker, D.; Barnum, S. H.; Barone, F.; Barr, B.; Barsotti, L.; Barsuglia, M.; Barton, M. A.; Bartos, I.; Bassiri, R.; Basti, A.; Batch, J.; Bauchrowitz, J.; Bauer, Th. S.; Bebronne, M.; Behnke, B.; Bejger, M.; Beker, M. G.; Bell, A. S.; Bell, C.; Belopolski, I.; Bergmann, G.; Berliner, J. M.; Bertolini, A.; Bessis, D.; Betzwieser, J.; Beyersdorf, P. T.; Bhadbhade, T.; Bilenko, I. A.; Billingsley, G.; Birch, J.; Bitossi, M.; Bizouard, M. A.; Black, E.; Blackburn, J. K.; Blackburn, L.; Blair, D.; Blom, M.; Bock, O.; Bodiya, T. P.; Boer, M.; Bogan, C.; Bond, C.; Bondu, F.; Bonelli, L.; Bonnand, R.; Bork, R.; Born, M.; Bose, S.; Bosi, L.; Bowers, J.; Bradaschia, C.; Brady, P. R.; Braginsky, V. B.; Branchesi, M.; Brannen, C. A.; Brau, J. E.; Breyer, J.; Briant, T.; Bridges, D. O.; Brillet, A.; Brinkmann, M.; Brisson, V.; Britzger, M.; Brooks, A. F.; Brown, D. A.; Brown, D. D.; Brückner, F.; Bulik, T.; Bulten, H. J.; Buonanno, A.; Buskulic, D.; Buy, C.; Byer, R. L.; Cadonati, L.; Cagnoli, G.; Calderón Bustillo, J.; Calloni, E.; Camp, J. B.; Campsie, P.; Cannon, K. C.; Canuel, B.; Cao, J.; Capano, C. D.; Carbognani, F.; Carbone, L.; Caride, S.; Castiglia, A.; Caudill, S.; Cavaglià, M.; Cavalier, F.; Cavalieri, R.; Cella, G.; Cepeda, C.; Cesarini, E.; Chakraborty, R.; Chalermsongsak, T.; Chao, S.; Charlton, P.; Chassande-Mottin, E.; Chen, X.; Chen, Y.; Chincarini, A.; Chiummo, A.; Cho, H. S.; Chow, J.; Christensen, N.; Chu, Q.; Chua, S. S. Y.; Chung, S.; Ciani, G.; Clara, F.; Clark, D. E.; Clark, J. A.; Cleva, F.; Coccia, E.; Cohadon, P.-F.; Colla, A.; Colombini, M.; Constancio, M., Jr.; Conte, A.; Conte, R.; Cook, D.; Corbitt, T. R.; Cordier, M.; Cornish, N.; Corsi, A.; Costa, C. A.; Coughlin, M. W.; Coulon, J.-P.; Countryman, S.; Couvares, P.; Coward, D. M.; Cowart, M.; Coyne, D. C.; Craig, K.; Creighton, J. D. E.; Creighton, T. D.; Crowder, S. G.; Cumming, A.; Cunningham, L.; Cuoco, E.; Dahl, K.; Dal Canton, T.; Damjanic, M.; Danilishin, S. L.; D'Antonio, S.; Danzmann, K.; Dattilo, V.; Daudert, B.; Daveloza, H.; Davier, M.; Davies, G. S.; Daw, E. J.; Day, R.; Dayanga, T.; De Rosa, R.; Debreczeni, G.; Degallaix, J.; Del Pozzo, W.; Deleeuw, E.; Deléglise, S.; Denker, T.; Dent, T.; Dereli, H.; Dergachev, V.; DeRosa, R.; DeSalvo, R.; Dhurandhar, S.; Di Fiore, L.; Di Lieto, A.; Di Palma, I.; Di Virgilio, A.; Díaz, M.; Dietz, A.; Dmitry, K.; Donovan, F.; Dooley, K. L.; Doravari, S.; Drago, M.; Drever, R. W. P.; Driggers, J. C.; Du, Z.; Dumas, J.-C.; Dwyer, S.; Eberle, T.; Edwards, M.; Effler, A.; Ehrens, P.; Eichholz, J.; Eikenberry, S. S.; Endrőczi, G.; Essick, R.; Etzel, T.; Evans, K.; Evans, M.; Evans, T.; Factourovich, M.; Fafone, V.; Fairhurst, S.; Fang, Q.; Farr, B.; Farr, W.; Favata, M.; Fazi, D.; Fehrmann, H.; Feldbaum, D.; Ferrante, I.; Ferrini, F.; Fidecaro, F.; Finn, L. S.; Fiori, I.; Fisher, R.; Flaminio, R.; Foley, E.; Foley, S.; Forsi, E.; Forte, L. A.; Fotopoulos, N.; Fournier, J.-D.; Franco, S.; Frasca, S.; Frasconi, F.; Frede, M.; Frei, M.; Frei, Z.; Freise, A.; Frey, R.; Fricke, T. T.; Fritschel, P.; Frolov, V. V.; Fujimoto, M.-K.; Fulda, P.; Fyffe, M.; Gair, J.; Gammaitoni, L.; Garcia, J.; Garufi, F.; Gehrels, N.; Gemme, G.; Genin, E.; Gennai, A.; Gergely, L.; Ghosh, S.; Giaime, J. A.; Giampanis, S.; Giardina, K. D.; Giazotto, A.; Gil-Casanova, S.; Gill, C.; Gleason, J.; Goetz, E.; Goetz, R.; Gondan, L.; González, G.; Gordon, N.; Gorodetsky, M. L.; Gossan, S.; Goßler, S.; Gouaty, R.; Graef, C.; Graff, P. B.; Granata, M.; Grant, A.; Gras, S.; Gray, C.; Greenhalgh, R. J. S.; Gretarsson, A. M.; Griffo, C.; Grote, H.; Grover, K.; Grunewald, S.; Guidi, G. M.; Guido, C.; Gushwa, K. E.; Gustafson, E. K.; Gustafson, R.; Hall, B.; Hall, E.; Hammer, D.; Hammond, G.; Hanke, M.; Hanks, J.; Hanna, C.; Hanson, J.; Harms, J.; Harry, G. M.; Harry, I. W.; Harstad, E. D.; Hartman, M. T.; Haughian, K.; Hayama, K.; Heefner, J.; Heidmann, A.; Heintze, M.; Heitmann, H.; Hello, P.; Hemming, G.; Hendry, M.; Heng, I. S.; Heptonstall, A. W.; Heurs, M.; Hild, S.; Hoak, D.; Hodge, K. A.; Holt, K.; Holtrop, M.; Hong, T.; Hooper, S.; Horrom, T.; Hosken, D. J.; Hough, J.; Howell, E. J.; Hu, Y.; Hua, Z.; Huang, V.; Huerta, E. A.; Hughey, B.; Husa, S.; Huttner, S. H.; Huynh, M.; Huynh-Dinh, T.; Iafrate, J.; Ingram, D. R.; Inta, R.; Isogai, T.; Ivanov, A.; Iyer, B. R.; Izumi, K.; Jacobson, M.; James, E.; Jang, H.; Jang, Y. J.; Jaranowski, P.; Jiménez-Forteza, F.; Johnson, W. W.; Jones, D.; Jones, D. I.; Jones, R.; Jonker, R. J. G.; Ju, L.; K, Haris; Kalmus, P.; Kalogera, V.; Kandhasamy, S.; Kang, G.; Kanner, J. B.; Kasprzack, M.; Kasturi, R.; Katsavounidis, E.; Katzman, W.; Kaufer, H.; Kaufman, K.; Kawabe, K.; Kawamura, S.; Kawazoe, F.; Kéfélian, F.; Keitel, D.; Kelley, D. B.; Kells, W.; Keppel, D. G.; Khalaidovski, A.; Khalili, F. Y.; Khazanov, E. A.; Kim, B. K.; Kim, C.; Kim, K.; Kim, N.; Kim, W.; Kim, Y.-M.; King, E. J.; King, P. J.; Kinzel, D. L.; Kissel, J. S.; Klimenko, S.; Kline, J.; Koehlenbeck, S.; Kokeyama, K.; Kondrashov, V.; Koranda, S.; Korth, W. Z.; Kowalska, I.; Kozak, D.; Kremin, A.; Kringel, V.; Krishnan, B.; Królak, A.; Kucharczyk, C.; Kudla, S.; Kuehn, G.; Kumar, A.; Kumar, P.; Kumar, R.; Kurdyumov, R.; Kwee, P.; Landry, M.; Lantz, B.; Larson, S.; Lasky, P. D.; Lawrie, C.; Lazzarini, A.; Le Roux, A.; Leaci, P.; Lebigot, E. O.; Lee, C.-H.; Lee, H. K.; Lee, H. M.; Lee, J.; Lee, J.; Leonardi, M.; Leong, J. R.; Leroy, N.; Letendre, N.; Levine, B.; Lewis, J. B.; Lhuillier, V.; Li, T. G. F.; Lin, A. C.; Littenberg, T. B.; Litvine, V.; Liu, F.; Liu, H.; Liu, Y.; Liu, Z.; Lloyd, D.; Lockerbie, N. A.; Lockett, V.; Lodhia, D.; Loew, K.; Logue, J.; Lombardi, A. L.; Lorenzini, M.; Loriette, V.; Lormand, M.; Losurdo, G.; Lough, J.; Luan, J.; Lubinski, M. J.; Lück, H.; Lundgren, A. P.; Macarthur, J.; Macdonald, E.; Machenschalk, B.; MacInnis, M.; Macleod, D. M.; Magana-Sandoval, F.; Mageswaran, M.; Mailand, K.; Majorana, E.; Maksimovic, I.; Malvezzi, V.; Man, N.; Manca, G. M.; Mandel, I.; Mandic, V.; Mangano, V.; Mantovani, M.; Marchesoni, F.; Marion, F.; Márka, S.; Márka, Z.; Markosyan, A.; Maros, E.; Marque, J.; Martelli, F.; Martin, I. W.; Martin, R. M.; Martinelli, L.; Martynov, D.; Marx, J. N.; Mason, K.; Masserot, A.; Massinger, T. J.; Matichard, F.; Matone, L.; Matzner, R. A.; Mavalvala, N.; May, G.; Mazumder, N.; Mazzolo, G.; McCarthy, R.; McClelland, D. E.; McGuire, S. C.; McIntyre, G.; McIver, J.; Meacher, D.; Meadors, G. D.; Mehmet, M.; Meidam, J.; Meier, T.; Melatos, A.; Mendell, G.; Mercer, R. A.; Meshkov, S.; Messenger, C.; Meyer, M. S.; Miao, H.; Michel, C.; Mikhailov, E. E.; Milano, L.; Miller, J.; Minenkov, Y.; Mingarelli, C. M. F.; Mitra, S.; Mitrofanov, V. P.; Mitselmakher, G.; Mittleman, R.; Moe, B.; Mohan, M.; Mohapatra, S. R. P.; Mokler, F.; Moraru, D.; Moreno, G.; Morgado, N.; Mori, T.; Morriss, S. R.; Mossavi, K.; Mours, B.; Mow-Lowry, C. M.; Mueller, C. L.; Mueller, G.; Mukherjee, S.; Mullavey, A.; Munch, J.; Murphy, D.; Murray, P. G.; Mytidis, A.; Nagy, M. F.; Nanda Kumar, D.; Nardecchia, I.; Nash, T.; Naticchioni, L.; Nayak, R.; Necula, V.; Neri, I.; Newton, G.; Nguyen, T.; Nishida, E.; Nishizawa, A.; Nitz, A.; Nocera, F.; Nolting, D.; Normandin, M. E.; Nuttall, L. K.; Ochsner, E.; O'Dell, J.; Oelker, E.; Ogin, G. H.; Oh, J. J.; Oh, S. H.; Ohme, F.; Oppermann, P.; O'Reilly, B.; Ortega Larcher, W.; O'Shaughnessy, R.; Osthelder, C.; Ottaway, D. J.; Ottens, R. S.; Ou, J.; Overmier, H.; Owen, B. J.; Padilla, C.; Pai, A.; Palomba, C.; Pan, Y.; Pankow, C.; Paoletti, F.; Paoletti, R.; Papa, M. A.; Paris, H.; Pasqualetti, A.; Passaquieti, R.; Passuello, D.; Pedraza, M.; Peiris, P.; Penn, S.; Perreca, A.; Phelps, M.; Pichot, M.; Pickenpack, M.; Piergiovanni, F.; Pierro, V.; Pinard, L.; Pindor, B.; Pinto, I. M.; Pitkin, M.; Pletsch, H. J.; Poeld, J.; Poggiani, R.; Poole, V.; Poux, C.; Predoi, V.; Prestegard, T.; Price, L. R.; Prijatelj, M.; Principe, M.; Privitera, S.; Prix, R.; Prodi, G. A.; Prokhorov, L.; Puncken, O.; Punturo, M.; Puppo, P.; Quetschke, V.; Quintero, E.; Quitzow-James, R.; Raab, F. J.; Rabeling, D. S.; Rácz, I.; Radkins, H.; Raffai, P.; Raja, S.; Rajalakshmi, G.; Rakhmanov, M.; Ramet, C.; Rapagnani, P.; Raymond, V.; Re, V.; Reed, C. M.; Reed, T.; Regimbau, T.; Reid, S.; Reitze, D. H.; Ricci, F.; Riesen, R.; Riles, K.; Robertson, N. A.; Robinet, F.; Rocchi, A.; Roddy, S.; Rodriguez, C.; Rodruck, M.; Roever, C.; Rolland, L.; Rollins, J. G.; Romano, J. D.; Romano, R.; Romanov, G.; Romie, J. H.; Rosińska, D.; Rowan, S.; Rüdiger, A.; Ruggi, P.; Ryan, K.; Salemi, F.; Sammut, L.; Sandberg, V.; Sanders, J.; Sannibale, V.; Santiago-Prieto, I.; Saracco, E.; Sassolas, B.; Sathyaprakash, B. S.; Saulson, P. R.; Savage, R.; Schilling, R.; Schnabel, R.; Schofield, R. M. S.; Schreiber, E.; Schuette, D.; Schulz, B.; Schutz, B. F.; Schwinberg, P.; Scott, J.; Scott, S. M.; Seifert, F.; Sellers, D.; Sengupta, A. S.; Sentenac, D.; Sergeev, A.; Shaddock, D.; Shah, S.; Shahriar, M. S.; Shaltev, M.; Shapiro, B.; Shawhan, P.; Shoemaker, D. H.; Sidery, T. L.; Siellez, K.; Siemens, X.; Sigg, D.; Simakov, D.; Singer, A.; Singer, L.; Sintes, A. M.; Skelton, G. R.; Slagmolen, B. J. J.; Slutsky, J.; Smith, J. R.; Smith, M. R.; Smith, R. J. E.; Smith-Lefebvre, N. D.; Soden, K.; Son, E. J.; Sorazu, B.; Souradeep, T.; Sperandio, L.; Staley, A.; Steinert, E.; Steinlechner, J.; Steinlechner, S.; Steplewski, S.; Stevens, D.; Stochino, A.; Stone, R.; Strain, K. A.; Strigin, S.; Stroeer, A. S.; Sturani, R.; Stuver, A. L.; Summerscales, T. Z.; Susmithan, S.; Sutton, P. J.; Swinkels, B.; Szeifert, G.; Tacca, M.; Talukder, D.; Tang, L.; Tanner, D. B.; Tarabrin, S. P.; Taylor, R.; ter Braack, A. P. M.; Thirugnanasambandam, M. P.; Thomas, M.; Thomas, P.; Thorne, K. A.; Thorne, K. S.; Thrane, E.; Tiwari, V.; Tokmakov, K. V.; Tomlinson, C.; Toncelli, A.; Tonelli, M.; Torre, O.; Torres, C. V.; Torrie, C. I.; Travasso, F.; Traylor, G.; Tse, M.; Ugolini, D.; Unnikrishnan, C. S.; Vahlbruch, H.; Vajente, G.; Vallisneri, M.; van den Brand, J. F. J.; Van Den Broeck, C.; van der Putten, S.; van der Sluys, M. V.; van Heijningen, J.; van Veggel, A. A.; Vass, S.; Vasúth, M.; Vaulin, R.; Vecchio, A.; Vedovato, G.; Veitch, J.; Veitch, P. J.; Venkateswara, K.; Verkindt, D.; Verma, S.; Vetrano, F.; Viceré, A.; Vincent-Finley, R.; Vinet, J.-Y.; Vitale, S.; Vlcek, B.; Vo, T.; Vocca, H.; Vorvick, C.; Vousden, W. D.; Vrinceanu, D.; Vyachanin, S. P.; Wade, A.; Wade, L.; Wade, M.; Waldman, S. J.; Walker, M.; Wallace, L.; Wan, Y.; Wang, J.; Wang, M.; Wang, X.; Wanner, A.; Ward, R. L.; Was, M.; Weaver, B.; Wei, L.-W.; Weinert, M.; Weinstein, A. J.; Weiss, R.; Welborn, T.; Wen, L.; Wessels, P.; West, M.; Westphal, T.; Wette, K.; Whelan, J. T.; Whitcomb, S. E.; White, D. J.; Whiting, B. F.; Wibowo, S.; Wiesner, K.; Wilkinson, C.; Williams, L.; Williams, R.; Williams, T.; Willis, J. L.; Willke, B.; Wimmer, M.; Winkelmann, L.; Winkler, W.; Wipf, C. C.; Wittel, H.; Woan, G.; Worden, J.; Yablon, J.; Yakushin, I.; Yamamoto, H.; Yancey, C. C.; Yang, H.; Yeaton-Massey, D.; Yoshida, S.; Yum, H.; Yvert, M.; Zadrożny, A.; Zanolin, M.; Zendri, J.-P.; Zhang, F.; Zhang, L.; Zhao, C.; Zhu, H.; Zhu, X. J.; Zotov, N.; Zucker, M. E.; Zweizig, J.

    2013-11-01

    We present the results of a directed search for continuous gravitational waves from unknown, isolated neutron stars in the Galactic center region, performed on two years of data from LIGO’s fifth science run from two LIGO detectors. The search uses a semicoherent approach, analyzing coherently 630 segments, each spanning 11.5 hours, and then incoherently combining the results of the single segments. It covers gravitational wave frequencies in a range from 78 to 496 Hz and a frequency-dependent range of first-order spindown values down to -7.86×10-8Hz/s at the highest frequency. No gravitational waves were detected. The 90% confidence upper limits on the gravitational wave amplitude of sources at the Galactic center are ˜3.35×10-25 for frequencies near 150 Hz. These upper limits are the most constraining to date for a large-parameter-space search for continuous gravitational wave signals.

  20. Recent searches for continuous gravitational waves

    NASA Astrophysics Data System (ADS)

    Riles, Keith

    2017-12-01

    Gravitational wave astronomy opened dramatically in September 2015 with the LIGO discovery of a distant and massive binary black hole coalescence. The more recent discovery of a binary neutron star merger, followed by a gamma ray burst (GRB) and a kilonova, reinforces the excitement of this new era, in which we may soon see other sources of gravitational waves, including continuous, nearly monochromatic signals. Potential continuous wave (CW) sources include rapidly spinning galactic neutron stars and more exotic possibilities, such as emission from axion Bose Einstein “clouds” surrounding black holes. Recent searches in Advanced LIGO data are presented, and prospects for more sensitive future searches are discussed.

  1. PROPOSED SIMPLE METHOD FOR ELECTROCARDIOGRAM RECORDING IN FREE-RANGING ASIAN ELEPHANTS (ELEPHAS MAXIMUS).

    PubMed

    Chai, Norin; Pouchelon, Jean Louis; Bouvard, Jonathan; Sillero, Leonor Camacho; Huynh, Minh; Segalini, Vincent; Point, Lisa; Croce, Veronica; Rigaux, Goulven; Highwood, Jack; Chetboul, Valérie

    2016-03-01

    Electrocardiography represents a relevant diagnostic tool for detecting cardiac disease in animals. Elephants can present various congenital and acquired cardiovascular diseases. However, few electrophysiologic studies have been reported in captive elephants, mainly due to challenging technical difficulties in obtaining good-quality electrocardiogram (ECG) tracings, and no data are currently available for free-ranging Asian elephants (Elephas maximus). The purpose of this pilot prospective study was to evaluate the feasibility of using a simple method for recording ECG tracings in wild, apparently healthy, unsedated Asian elephants (n = 7) in the standing position. Successful six-lead recordings (I, II, III, aVR, aVL, and aVF) were obtained, with the aVL lead providing the best-quality tracings in most animals. Variables measured in the aVL lead included heart rate, amplitudes and duration of the P waves, QRS complexes, T and U waves, and duration of the PR, QT, and QU intervals. A negative deflection following positive P waves, representative of an atrial repolarization wave (Ta wave), was observed for five out of the seven elephants.

  2. T-Wave Alternans Is Linked to Microvascular Obstruction and to Recurrent Coronary Ischemia After Myocardial Infarction.

    PubMed

    Floré, V; Claus, P; Vos, M A; Vandenberk, B; Van Soest, S; Sipido, K R; Adriaenssens, T; Bogaert, J; Desmet, W; Willems, R

    2015-11-01

    The purpose of this study is to investigate the relationship between T-wave alternans (TWA), infarct size and microvascular obstruction (MVO) and recurrent cardiac morbidity after ST elevation myocardial infarction (STEMI). One hundred six patients underwent TWA testing 1-12 months and 57 patients underwent cardiac magnetic resonance imaging (MRI) in the first 2-4 days after STEMI. During follow-up (3.5 ± 0.5 years), death (n = 2), ventricular tachycardia (n = 3), supraventricular tachycardia (n = 4), heart failure (n = 3) and recurrent coronary ischemia (n = 25) were observed. After multivariate analysis, positive TWA (HR2.59, CI1.10-6.11, p0.024) and larger MVO (HR1.08, CI1.01-1.16, p0.034) were associated with recurrent angina or ACS. Presence of MVO was correlated with TWA (Spearman rho 0.404, p0.002) and the impairment of LVEF (-0.524, p < 0.001). Patients after STEMI remain at a high risk of symptoms of coronary ischemia. The presence of MVO and TWA 1-12 months after STEMI is related to each other and to recurrent angina or ACS.

  3. A multichannel decision-level fusion method for T wave alternans detection

    NASA Astrophysics Data System (ADS)

    Ye, Changrong; Zeng, Xiaoping; Li, Guojun; Shi, Chenyuan; Jian, Xin; Zhou, Xichuan

    2017-09-01

    Sudden cardiac death (SCD) is one of the most prominent causes of death among patients with cardiac diseases. Since ventricular arrhythmia is the main cause of SCD and it can be predicted by T wave alternans (TWA), the detection of TWA in the body-surface electrocardiograph (ECG) plays an important role in the prevention of SCD. But due to the multi-source nature of TWA, the nonlinear propagation through thorax, and the effects of the strong noises, the information from different channels is uncertain and competitive with each other. As a result, the single-channel decision is one-sided while the multichannel decision is difficult to reach a consensus on. In this paper, a novel multichannel decision-level fusion method based on the Dezert-Smarandache Theory is proposed to address this issue. Due to the redistribution mechanism for highly competitive information, higher detection accuracy and robustness are achieved. It also shows promise to low-cost instruments and portable applications by reducing demands for the synchronous sampling. Experiments on the real records from the Physikalisch-Technische Bundesanstalt diagnostic ECG database indicate that the performance of the proposed method improves by 12%-20% compared with the one-dimensional decision method based on the periodic component analysis.

  4. Continuous cytokine haemoadsorption incorporated into a venoarterial ECMO circuit for the management of postcardiotomy cardiogenic and septic shock - a case report.

    PubMed

    Nemeth, Endre; Szigeti, Szabolcs; Varga, Tamas; Daroczi, Laszlo; Barati, Zoltan; Merkely, Bela; Gal, Janos

    2018-05-01

    The acute surgical treatment of infective endocarditis (IE) carries a high risk of postoperative mortality. Most complications are linked to uncontrolled sepsis and inflammatory processes. Cytokine haemoadsorption is an extracorporeal technique which has benefits reported in haemodynamic stability and inflammatory response. A 46-year-old male patient underwent emergency cardiac surgery due to progressive IE. Postcardiotomy cardiogenic shock associated with cardiac surgery required the implantation of venoarterial (VA)-ECMO. Three days later, the patient developed secondary septic shock. The novel application of continuous CytoSorb TM treatment installed in the VA-ECMO circuit is demonstrated in this case during the management of simultaneous shocks. Advanced intensive care led to an improvement in the patient's condition, which facilitated successful weaning from mechanical ventilation. However, the patient died from a new onset fulminant septic shock two months after his initial cardiac surgery. VA-ECMO is suitable for installation of the CytoSorb TM cartridge. This modality could be an option for high-volume, continuous cytokine haemoadsorption when VA-ECMO is employed without renal replacement therapy. This specific application of CytoSorb TM was safe, feasible and contributed to the optimal management of simultaneous shocks.

  5. Tricuspid annulus: A spatial and temporal analysis

    PubMed Central

    Knio, Ziyad O.; Montealegre-Gallegos, Mario; Yeh, Lu; Chaudary, Bilal; Jeganathan, Jelliffe; Matyal, Robina; Khabbaz, Kamal R.; Liu, David C.; Senthilnathan, Venkatachalam; Mahmood, Feroze

    2016-01-01

    Background: Traditional two-dimensional (2D) echocardiographic evaluation of tricuspid annulus (TA) dilation is based on single-frame measurements of the septolateral (S-L) dimension. This may not represent either the axis or the extent of dynamism through the entire cardiac cycle. In this study, we used real-time 3D transesophageal echocardiography (TEE) to analyze geometric changes in multiple axes of the TA throughout the cardiac cycle in patients without right ventricular abnormalities. Materials and Methods: R-wave-gated 3D TEE images of the TA were acquired in 39 patients undergoing cardiovascular surgery. The patients with abnormal right ventricular/tricuspid structure or function were excluded from the study. For each patient, eight points along the TA were traced in the 3D dataset and used to reconstruct the TA at four stages of the cardiac cycle (end- and mid-systole, end- and mid-diastole). Statistical analyses were applied to determine whether TA area, perimeter, axes, and planarity changed significantly over each stage of the cardiac cycle. Results: TA area (P = 0.012) and perimeter (P = 0.024) both changed significantly over the cardiac cycle. Of all the axes, only the posterolateral-anteroseptal demonstrated significant dynamism (P < 0.001). There was also a significant displacement in the vertical axis between the points and the regression plane in end-systole (P < 0.001), mid-diastole (P = 0.014), and mid-systole (P < 0.001). Conclusions: The TA demonstrates selective dynamism over the cardiac cycle, and its axis of maximal dynamism is different from the axis (S-L) that is routinely measured with 2D TEE. PMID:27716689

  6. A prospective evaluation of 68 patients suffering blunt chest trauma for evidence of cardiac injury.

    PubMed

    Helling, T S; Duke, P; Beggs, C W; Crouse, L J

    1989-07-01

    The prevalence and significance of cardiac injury following blunt chest trauma is largely unknown. Although electrocardiography (ECG) and creatinine phosphokinase isoenzyme (CPK-MB) determination have traditionally been used in determining cardiac injury, recent developments in two-dimensional echocardiography (ECHO) as a noninvasive diagnostic tool have led to its use in detecting structural cardiac damage following trauma. In an attempt to determine the occurrence and consequences of cardiac injury we prospectively evaluated 68 patients at one institution using ECHO, serial ECG, and serial CPK-MB determinations in the first 3 days following hospital admission. Patients were selected who had evidence of blunt chest injury on examination or by mechanism of injury. The mean age of the 68 patients was 36.3 +/- 19.6 years and the mean Injury Severity Score, 21.5 +/- 11.6. Forty-nine patients (72%) were found to have an abnormal ECHO, ECG, or CPK-MB (greater than 3%). Eighteen patients (26%) had abnormal ECHOs consisting of seven right ventricular contusions, three left ventricular contusions, three contusions of both chambers, four pericardial effusions, and one small ventricular septal defect. Only three contusions were associated with elevated CPK-MB and seven with abnormal ECGs. Abnormalities of ECG included 18 patients with S-T, T wave changes, axis shifts (11 patients), and bundle branch or hemiblocks (10 patients). No patient died or experienced serious morbidity as a result of their cardiac injury, including 12 patients who underwent surgical procedures with general anesthesia within 30 days of admission.(ABSTRACT TRUNCATED AT 250 WORDS)

  7. [Paralysis, organic brain syndrome, and cardiac dysrhythmias caused by chronic laxative abuse (author's transl)].

    PubMed

    Dahlmann, W; Volles, E; Lüderitz, B

    1977-10-28

    A 39-year-old woman developed generalised paralysis, reversible organic brain syndrome, and cardiac dysrhythmias after 15 years of laxative abuse. Under continuous and cautious administration of potassium the cardiac rhythm became normal within four days and two days later the paralysis and organic brain syndrome almost disappeared. The cause of the psychiatric symptoms is thought to be cerebral potassium deficiency and an abnormal sodium/potassium equilibrium. Other clinical signs and symptoms due to extreme potassium depletion are presented. The importance of Na+/K+-activated membrane ATP-ase in myocardium and CNS is discussed.

  8. Combination of continuous renal replacement therapies (CRRT) and extracorporeal membrane oxygenation (ECMO) for advanced cardiac patients.

    PubMed

    Yap, Hon-Jek; Chen, Yung-Chang; Fang, Ji-Tseng; Huang, Chiu-Ching

    2003-03-01

    The critically ill patients may require mechanical ventilation, cardiac mechanical support, and other types of critical support. Extracorporeal membrane oxygenation (ECMO) is a supportive therapy, which provides good cardiopulmonary and end-organ support. Continuous renal replacement therapies (CRRT) exhibit important advantages in terms of clinical tolerance and blood purification. This investigation aims to evaluate the acute renal failure in cardiac patients under ECMO, and assess the effect of combining these two technologies, ECMO and CRRT. Between December 1998 and June 2001, 10 adult cardiac patients were treated on ECMO. Five of them were treated with both ECMO and CRRT. The clinical outcomes were retrospectively analyzed. Of the 10 patients studied, five were men and five were women. The mean age of survivors and non-survivors was 37.00 +/- 14.54 years and 46.17 +/- 7.41 years, respectively. The overall mortality rate was 60%. Survivors did not differ significantly from non-survivors in age or gender. The APACHE II scores on the first day of ECMO support between survival and non-survival were 19.00 +/- 9.38 and 24.67 +/- 3.50 (P value = 0.392) (Table 2), which demonstrates no significant differences too. The cause of death in most patients was related to organ system failure during the 24 h immediately before ECMO started. Five patients with acute renal failure treated by CRRT were eventually died. The median and mean survival in this group on CRRT was 40.50 +/- 18.07 h and 92.60 +/- 60.50 h. We conclude that mortality rate for acute renal failure in cardiac patients under ECMO continues to be high. Our data suggest that acute renal failure is generally a part of multiorgan failure. This unique form of acute renal failure, causes generalized edema and fluid overload despite still low serum creatinine and azotemia, and deteriorates rapidly to death. From this study shows, advanced cardiac failure may need more aggressive and early initiation of ECMO support before acute renal failure develops. Acute renal failure in advanced heart failure under ECMO support means a grave sign, need aggressive heart transplantation therapy as soon as possible. Combination of CRRT and ECMO might serve an alternative therapy bridging the temporary replacement treatment and heart transplantation in advanced cardiac patients.

  9. Hierarchical multistage MCMC follow-up of continuous gravitational wave candidates

    NASA Astrophysics Data System (ADS)

    Ashton, G.; Prix, R.

    2018-05-01

    Leveraging Markov chain Monte Carlo optimization of the F statistic, we introduce a method for the hierarchical follow-up of continuous gravitational wave candidates identified by wide-parameter space semicoherent searches. We demonstrate parameter estimation for continuous wave sources and develop a framework and tools to understand and control the effective size of the parameter space, critical to the success of the method. Monte Carlo tests of simulated signals in noise demonstrate that this method is close to the theoretical optimal performance.

  10. Cardiac differentiation of cardiosphere-derived cells in scaffolds mimicking morphology of the cardiac extracellular matrix.

    PubMed

    Xu, Yanyi; Patnaik, Sourav; Guo, Xiaolei; Li, Zhenqing; Lo, Wilson; Butler, Ryan; Claude, Andrew; Liu, Zhenguo; Zhang, Ge; Liao, Jun; Anderson, Peter M; Guan, Jianjun

    2014-08-01

    Stem cell therapy has the potential to regenerate heart tissue after myocardial infarction (MI). The regeneration is dependent upon cardiac differentiation of the delivered stem cells. We hypothesized that timing of the stem cell delivery determines the extent of cardiac differentiation as cell differentiation is dependent on matrix properties such as biomechanics, structure and morphology, and these properties in cardiac extracellular matrix (ECM) continuously vary with time after MI. In order to elucidate the relationship between ECM properties and cardiac differentiation, we created an in vitro model based on ECM-mimicking fibers and a type of cardiac progenitor cell, cardiosphere-derived cells (CDCs). A simultaneous fiber electrospinning and cell electrospraying technique was utilized to fabricate constructs. By blending a highly soft hydrogel with a relatively stiff polyurethane and modulating fabrication parameters, tissue constructs with similar cell adhesion property but different global modulus, single fiber modulus, fiber density and fiber alignment were achieved. The CDCs remained alive within the constructs during a 1week culture period. CDC cardiac differentiation was dependent on the scaffold modulus, fiber volume fraction and fiber alignment. Two constructs with relatively low scaffold modulus, ∼50-60kPa, most significantly directed the CDC differentiation into mature cardiomyocytes as evidenced by gene expressions of cardiac troponin T (cTnT), calcium channel (CACNA1c) and cardiac myosin heavy chain (MYH6), and protein expressions of cardiac troponin I (cTnI) and connexin 43 (CX43). Of these two low-modulus constructs, the extent of differentiation was greater for lower fiber alignment and higher fiber volume fraction. These results suggest that cardiac ECM properties may have an effect on cardiac differentiation of delivered stem cells. Copyright © 2014 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  11. Temporal patterns of change in vital signs and Cardiac Arrest Risk Triage scores over the 48 hours preceding fatal in-hospital cardiac arrest.

    PubMed

    Oh, HyunSoo; Lee, KangIm; Seo, WhaSook

    2016-05-01

    To determine temporal patterns of vital sign and Cardiac Arrest Risk Triage score changes over the 48-hour period preceding cardiac arrest in an ICU setting. Vital sign instability usually occurs prior to cardiac arrest. However, few studies have been conducted on the temporal patterns of individual vital signs preceding cardiac arrest. A retrospective case-control study. The study subjects were 140 ICU patients (1 June 2011-31 December 2012): 46 died of cardiac arrest (case group), 45 died of other illnesses (control I group) and 49 were discharged after recovering (control II group). Initial detectable changes in blood pressure appeared 18-20 hours and became dramatic at 5-10 hours before cardiac arrest. Noticeable changes in heart rates began at 4 hours and became more prominent at 2 hours pre-arrest. No apparent patterns in respiratory rate changes were observed. Body temperatures usually indicated a hypothermic state pre-arrest. Cardiac Arrest Risk Triage scores were 16-18 at 48 hours pre-arrest and then continuously increased to 20. Only mean values of systolic blood pressures were significantly different between the three study groups. Mean diastolic blood pressures, heart rates, respiratory rates and Cardiac Arrest Risk Triage scores differed between the case and control II groups and between the control I and II groups. The study demonstrates vital sign instability preceded cardiac arrest and that the temporal patterns of changes in individual vital signs and Cardiac Arrest Risk Triage scores differed between groups. The findings of this study may aid the development of management strategies for cardiac arrest. © 2016 John Wiley & Sons Ltd.

  12. Phase-resolved analysis of the susceptibility of pinned spiral waves to far-field pacing in a two-dimensional model of excitable media

    PubMed Central

    Bittihn, Philip; Squires, Amgad; Luther, Gisa; Bodenschatz, Eberhard; Krinsky, Valentin; Parlitz, Ulrich; Luther, Stefan

    2010-01-01

    Life-threatening cardiac arrhythmias are associated with the existence of stable and unstable spiral waves. Termination of such complex spatio-temporal patterns by local control is substantially limited by anchoring of spiral waves at natural heterogeneities. Far-field pacing (FFP) is a new local control strategy that has been shown to be capable of unpinning waves from obstacles. In this article, we investigate in detail the FFP unpinning mechanism for a single rotating wave pinned to a heterogeneity. We identify qualitatively different phase regimes of the rotating wave showing that the concept of vulnerability is important but not sufficient to explain the failure of unpinning in all cases. Specifically, we find that a reduced excitation threshold can lead to the failure of unpinning, even inside the vulnerable window. The critical value of the excitation threshold (below which no unpinning is possible) decreases for higher electric field strengths and larger obstacles. In contrast, for a high excitation threshold, the success of unpinning is determined solely by vulnerability, allowing for a convenient estimation of the unpinning success rate. In some cases, we also observe phase resetting in discontinuous phase intervals of the spiral wave. This effect is important for the application of multiple stimuli in experiments. PMID:20368243

  13. Neuronal Networks in Children with Continuous Spikes and Waves during Slow Sleep

    ERIC Educational Resources Information Center

    Siniatchkin, Michael; Groening, Kristina; Moehring, Jan; Moeller, Friederike; Boor, Rainer; Brodbeck, Verena; Michel, Christoph M.; Rodionov, Roman; Lemieux, Louis; Stephani, Ulrich

    2010-01-01

    Epileptic encephalopathy with continuous spikes and waves during slow sleep is an age-related disorder characterized by the presence of interictal epileptiform discharges during at least greater than 85% of sleep and cognitive deficits associated with this electroencephalography pattern. The pathophysiological mechanisms of continuous spikes and…

  14. Predictability decomposition detects the impairment of brain-heart dynamical networks during sleep disorders and their recovery with treatment

    NASA Astrophysics Data System (ADS)

    Faes, Luca; Marinazzo, Daniele; Stramaglia, Sebastiano; Jurysta, Fabrice; Porta, Alberto; Giandomenico, Nollo

    2016-05-01

    This work introduces a framework to study the network formed by the autonomic component of heart rate variability (cardiac process η) and the amplitude of the different electroencephalographic waves (brain processes δ, θ, α, σ, β) during sleep. The framework exploits multivariate linear models to decompose the predictability of any given target process into measures of self-, causal and interaction predictability reflecting respectively the information retained in the process and related to its physiological complexity, the information transferred from the other source processes, and the information modified during the transfer according to redundant or synergistic interaction between the sources. The framework is here applied to the η, δ, θ, α, σ, β time series measured from the sleep recordings of eight severe sleep apnoea-hypopnoea syndrome (SAHS) patients studied before and after long-term treatment with continuous positive airway pressure (CPAP) therapy, and 14 healthy controls. Results show that the full and self-predictability of η, δ and θ decreased significantly in SAHS compared with controls, and were restored with CPAP for δ and θ but not for η. The causal predictability of η and δ occurred through significantly redundant source interaction during healthy sleep, which was lost in SAHS and recovered after CPAP. These results indicate that predictability analysis is a viable tool to assess the modifications of complexity and causality of the cerebral and cardiac processes induced by sleep disorders, and to monitor the restoration of the neuroautonomic control of these processes during long-term treatment.

  15. Anaesthesia for caesarean section in patients with cardiac disease.

    PubMed

    Chohan, Ursula; Afshan, Gauhar; Mone, Abdul

    2006-01-01

    This review contains material sourced from Med-Line and Pub-Med, search year 2002-2004. Material selected was pertaining to common cardiac ailments in pregnancy. Congenital cardiac problems i.e. Tetralogy of Fallot (TOF), Atrial Septal Defect (ASD), Ventricular Septal Defect (VSD), Eisenmengers syndrome, valvular heart disease, i.e. mitral stenosis, mitral regurgitation, aortic stensois and aortic regurgitation are discussed. Other cardiac conditions associated with pregnancy are pulmonary hypertension and peri-partum cardiomyopathy. Arrhythmias during pregnancy, vary from isolated premature to supra-ventricular and ventricular tachycardia, management is similar to non-pregnant patients. This review summarizes the current management of a parturient with cardiac disease requiring surgical delivery. Regional anaesthesia techniques are preferred as reflected in the current literature for patient with cardiac disease with minor alterations such as slow establishment of epidural for caesarean section or continuous spinal anaesthesia with very small incremental doses of local anaesthesia, maintaining the patient's SVR with vasopressors and fluid, monitoring of the fluid regimen with CVP and in some cardiac function with Swan Ganz catheter. Patients with Eisenmenger syndrome, pulmonary hypertension, should be advised to avoid pregnancy. In conclusion with vast advancements in obsterics care, improvements in cardiac surgery, many patients with cardiac disease can now be safely delivered surgically by skillful anaesthesiologists who are aware of the common potential intra-operative problems and the ability to respond to undesired events immediately.

  16. Current perspectives on cardiac amyloidosis

    PubMed Central

    Guan, Jian; Mishra, Shikha; Falk, Rodney H.

    2012-01-01

    Amyloidosis represents a group of diseases in which proteins undergo misfolding to form insoluble fibrils with subsequent tissue deposition. While almost all deposited amyloid fibers share a common nonbranched morphology, the affected end organs, clinical presentation, treatment strategies, and prognosis vary greatly among this group of diseases and are largely dependent on the specific amyloid precursor protein. To date, at least 27 precursor proteins have been identified to result in either local tissue or systemic amyloidosis, with nine of them manifesting in cardiac deposition and resulting in a syndrome termed “cardiac amyloidosis” or “amyloid cardiomyopathy.” Although cardiac amyloidosis has been traditionally considered to be a rare disorder, as clinical appreciation and understanding continues to grow, so too has the prevalence, suggesting that this disease may be greatly underdiagnosed. The most common form of cardiac amyloidosis is associated with circulating amyloidogenic monoclonal immunoglobulin light chain proteins. Other major cardiac amyloidoses result from a misfolding of products of mutated or wild-type transthyretin protein. While the various cardiac amyloidoses share a common functional consequence, namely, an infiltrative cardiomyopathy with restrictive pathophysiology leading to progressive heart failure, the underlying pathophysiology and clinical syndrome varies with each precursor protein. Herein, we aim to provide an up-to-date overview of cardiac amyloidosis from nomenclature to molecular mechanisms and treatment options, with a particular focus on amyloidogenic immunoglobulin light chain protein cardiac amyloidosis. PMID:22058156

  17. Structural and functional affection of the heart in protein energy malnutrition patients on admission and after nutritional recovery.

    PubMed

    El-Sayed, H L; Nassar, M F; Habib, N M; Elmasry, O A; Gomaa, S M

    2006-04-01

    The pathogenesis of different malnutrition diseases was suggested to affect the heart. This study was designed to detect cardiac affection in protein energy malnutrition (PEM) patients, whether clinically or by electrocardiogram (ECG) and echocardiogram, and to assess the value of the cardiac marker troponin I in patients at risk of myocardial injury with special emphasis on the effect of nutritional rehabilitation. The present study was carried out on 30 PEM infants (16 nonedematous - 14 edematous) and 10 apparently healthy age and sex-matched infants acting as the control group. All studied infants were subjected to full history taking laying stress on dietetic history, thorough clinical and anthropometric measurements. Echocardiography and ECG were also performed. Laboratory investigations were performed including complete blood count, CRP, total proteins, albumin, liver and kidney functions as well as estimation of troponin-I in blood by immulite. Following initial evaluation, all malnourished infants were subjected to nutritional rehabilitation program for approximately 8 weeks, after which the patients were re-evaluated using the same preinterventional parameters. The results of the present study demonstrated that electrical properties of myocardium assessed by ECG showed significant decrease of R wave and QTc interval in patients compared to controls with significant improvement after nutritional rehabilitation. Echocardigraphic changes showed that cardiac mass index was significantly lower in both groups of malnourished cases compared to the controls with significant increase after nutritional rehabilitation. The study showed that the parameters of left ventricular (LV) systolic function which are the ejection fraction, fractional shortening and velocity of circumferential fiber shortening were not significantly reduced in patients compared to the controls. The diastolic function also showed no significant difference in the E wave/A wave (e/a) ratio between patients and controls. However, the systolic time interval showed significantly higher LV pre-ejection index in patients in comparison to controls. Edematous and nonedematous cases did not show any significant differences in ECG and echocardigraphic data before or after nutritional rehabilitation. The hearts of two severely affected patients uniquely demonstrated marked decrease of LV end diastolic diameter (LEVDd) together with the detection of troponin-I in their sera. We can conclude that malnutrition, regardless of its type, has a definite effect on cardiac volume, muscle mass, as well as the electrical properties of the myocardium. The systolic functions of the heart are affected more than the diastolic functions and this affection becomes manifest only in severe cases and may constitute a bad prognostic parameter thus necessitating more intense management and strict follow-up of such cases.

  18. Ethical issues in critical care and cardiac arrest: clinical research, brain death, and organ donation.

    PubMed

    Donatelli, Luke A; Geocadin, Romergryko G; Williams, Michael A

    2006-09-01

    Cardiac arrest results in global hypoxic-ischemic brain injury from which there is a range of possible neurological outcomes. In most cases, patients may require a surrogate to make decisions regarding end-of-life care, including the withdrawal of life-sustaining therapies. This article reviews ethical considerations that arise in the clinical care of patients following cardiac arrest, including decisions to continue or withdraw life-sustaining therapies; brain death determination; and organ donation in the context of brain death and cardiac death (so-called non-heart-beating donation). This article also discusses ethical concerns pertaining to the design and conduct of resuscitation research that is necessary for the development of effective therapies to prevent anoxic brain injury or promote neurological recovery.

  19. Echocardiography in cardiac arrest: An emergency medicine review.

    PubMed

    Long, Brit; Alerhand, Stephen; Maliel, Kurian; Koyfman, Alex

    2018-03-01

    Cardiac arrest management primarily focuses on optimal chest compressions and early defibrillation for shockable cardiac rhythms. Non-shockable rhythms such as pulseless electrical activity (PEA) and asystole present challenges in management. Point-of-care ultrasound (POCUS) in cardiac arrest is promising. This review provides a focused assessment of POCUS in cardiac arrest, with an overview of transthoracic (TTE) and transesophageal echocardiogram (TEE), uses in arrest, and literature support. Cardiac arrest can be distinguished between shockable and non-shockable rhythms, with management varying based on the rhythm. POCUS provides a diagnostic and prognostic tool in the emergency department (ED), which may improve accuracy in clinical decision-making. Several protocols incorporate POCUS based on different cardiac views. TTE includes parasternal long axis, parasternal short axis, apical 4-chamber, and subxiphoid views, which may be used in cardiac arrest for diagnosis of underlying cause and potential prognostication. TEE is conducted by inserting the probe into the esophagus of intubated patients, with several studies evaluating its use in cardiac arrest. It is associated with few adverse effects, while allowing continued compressions (and evaluation of those compressions) and not interrupting resuscitation efforts. POCUS is a valuable diagnostic and prognostic tool in cardiac arrest, with recent literature supporting its diagnostic ability. TTE can guide resuscitation efforts dependent on the rhythm, though TTE should not interrupt other resuscitation measures. TEE can be useful during arrest, but further studies based in the ED are needed. Published by Elsevier Inc.

  20. The Chinese Cardiac Surgery Registry: Design and Data Audit.

    PubMed

    Rao, Chenfei; Zhang, Heng; Gao, Huawei; Zhao, Yan; Yuan, Xin; Hua, Kun; Hu, Shengshou; Zheng, Zhe

    2016-04-01

    In light of the burgeoning volume and certain variation of in-hospital outcomes of cardiac operations in China, a large patient-level registry was needed. We generated the Chinese Cardiac Surgery Registry (CCSR) database in 2013 to benchmark, continuously monitor, and provide feedback of the quality of adult cardiac operations. We report on the design of this database and provide an overview of participating sites and quality of data. We established a network of participating sites with an adult cardiac surgery volume of more than 100 operations per year for continuous web-based registry of in-hospital and follow-up data of coronary artery bypass grafting (CABG) and valve operations. After a routine data quality audit, we report the performance and quality of care back to the participating sites. In total, 87 centers participated and submitted 46,303 surgical procedures from January 2013 to December 2014. The timeliness rates of the short-list and in-hospital data submitted were 73.6% and 70.2%, respectively. The completeness and accuracy rates of the in-hospital data were 97.6% and 95.1%, respectively. We have provided 2 reports for each site and 1 national report regarding the performance of isolated CABG and valve operations. The newly launched CCSR with a national representativeness network and good data quality has the potential to act as an important platform for monitoring and improving cardiac surgical care in mainland China, as well as facilitating research projects, establishing benchmarking standards, and identifying potential areas for quality improvements (ClinicalTrials.gov No. NCT02400125). Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Top