Sample records for contrast agent database

  1. Molecular Imaging and Contrast Agent Database (MICAD): evolution and progress.

    PubMed

    Chopra, Arvind; Shan, Liang; Eckelman, W C; Leung, Kam; Latterner, Martin; Bryant, Stephen H; Menkens, Anne

    2012-02-01

    The purpose of writing this review is to showcase the Molecular Imaging and Contrast Agent Database (MICAD; www.micad.nlm.nih.gov ) to students, researchers, and clinical investigators interested in the different aspects of molecular imaging. This database provides freely accessible, current, online scientific information regarding molecular imaging (MI) probes and contrast agents (CA) used for positron emission tomography, single-photon emission computed tomography, magnetic resonance imaging, X-ray/computed tomography, optical imaging and ultrasound imaging. Detailed information on >1,000 agents in MICAD is provided in a chapter format and can be accessed through PubMed. Lists containing >4,250 unique MI probes and CAs published in peer-reviewed journals and agents approved by the United States Food and Drug Administration as well as a comma separated values file summarizing all chapters in the database can be downloaded from the MICAD homepage. Users can search for agents in MICAD on the basis of imaging modality, source of signal/contrast, agent or target category, pre-clinical or clinical studies, and text words. Chapters in MICAD describe the chemical characteristics (structures linked to PubChem), the in vitro and in vivo activities, and other relevant information regarding an imaging agent. All references in the chapters have links to PubMed. A Supplemental Information Section in each chapter is available to share unpublished information regarding an agent. A Guest Author Program is available to facilitate rapid expansion of the database. Members of the imaging community registered with MICAD periodically receive an e-mail announcement (eAnnouncement) that lists new chapters uploaded to the database. Users of MICAD are encouraged to provide feedback, comments, or suggestions for further improvement of the database by writing to the editors at micad@nlm.nih.gov.

  2. Molecular Imaging and Contrast Agent Database (MICAD): Evolution and Progress

    PubMed Central

    Chopra, Arvind; Shan, Liang; Eckelman, W. C.; Leung, Kam; Latterner, Martin; Bryant, Stephen H.; Menkens, Anne

    2011-01-01

    The purpose of writing this review is to showcase the Molecular Imaging and Contrast Agent Database (MICAD; www.micad.nlm.nih.gov) to students, researchers and clinical investigators interested in the different aspects of molecular imaging. This database provides freely accessible, current, online scientific information regarding molecular imaging (MI) probes and contrast agents (CA) used for positron emission tomography, single-photon emission computed tomography, magnetic resonance imaging, x-ray/computed tomography, optical imaging and ultrasound imaging. Detailed information on >1000 agents in MICAD is provided in a chapter format and can be accessed through PubMed. Lists containing >4250 unique MI probes and CAs published in peer-reviewed journals and agents approved by the United States Food and Drug Administration (FDA) as well as a CSV file summarizing all chapters in the database can be downloaded from the MICAD homepage. Users can search for agents in MICAD on the basis of imaging modality, source of signal/contrast, agent or target category, preclinical or clinical studies, and text words. Chapters in MICAD describe the chemical characteristics (structures linked to PubChem), the in vitro and in vivo activities and other relevant information regarding an imaging agent. All references in the chapters have links to PubMed. A Supplemental Information Section in each chapter is available to share unpublished information regarding an agent. A Guest Author Program is available to facilitate rapid expansion of the database. Members of the imaging community registered with MICAD periodically receive an e-mail announcement (eAnnouncement) that lists new chapters uploaded to the database. Users of MICAD are encouraged to provide feedback, comments or suggestions for further improvement of the database by writing to the editors at: micad@nlm.nih.gov PMID:21989943

  3. Design Principles of Nanoparticles as Contrast Agents for Magnetic Resonance Imaging

    NASA Astrophysics Data System (ADS)

    Shan, Liang; Gu, Xinbin; Wang, Paul

    2013-09-01

    Molecular imaging is an emerging field that introduces molecular agents into traditional imaging techniques, enabling visualization, characterization and measurement of biological processes at the molecular and cellular levels in humans and other living systems. The promise of molecular imaging lies in its potential for selective potency by targeting biomarkers or molecular targets and the imaging agents serve as reporters for the selectivity of targeting. Development of an efficient molecular imaging agent depends on well-controlled high-quality experiment design involving target selection, agent synthesis, in vitro characterization, and in vivo animal characterization before it is applied in humans. According to the analysis from the Molecular Imaging and Contrast Agent Database (MICAD, ), more than 6000 molecular imaging agents with sufficient preclinical evaluation have been reported to date in the literature and this number increases by 250-300 novel agents each year. The majority of these agents are radionuclides, which are developed for positron emission tomography (PET) and single photon emission computed tomography (SPECT). Contrast agents for magnetic resonance imaging (MRI) account for only a small part. This is largely due to the fact that MRI is currently not a fully quantitative imaging technique and is less sensitive than PET and SPECT. However, because of the superior ability to simultaneously extract molecular and anatomic information, molecular MRI is attracting significant interest and various targeted nanoparticle contrast agents have been synthesized for MRI. The first and one of the most critical steps in developing a targeted nanoparticle contrast agent is target selection, which plays the central role and forms the basis for success of molecular imaging. This chapter discusses the design principles of targeted contrast agents in the emerging frontiers of molecular MRI.

  4. Adverse reactions to contrast media: an analysis of spontaneous reports in the database of the pharmacovigilance programme of India.

    PubMed

    Kalaiselvan, Vivekanandan; Sharma, Surbhi; Singh, Gyanendra Nath

    2014-09-01

    Contrast media are used widely to improve medical imaging. Like all other pharmaceuticals, these agents are not completely devoid of risk, and continuous monitoring of adverse reactions with these agents is important. Spontaneous reporting is the simplest method for understanding the safety profile of pharmaceutical products after their approval. Our objective was to identify the pattern and characteristics of adverse reactions attributed to contrast media in the Indian population reported to the National Coordination Centre for the Pharmacovigilance Programme of India (NCC-PvPI). Individual case safety reports (ICSRs) attributed to contrast media submitted spontaneously to the NCC-PvPI were extracted from the database for July 2010 to September 2013. We analysed these reports for information related to reporter's professional category, patient's age and sex, reporter's diagnosis of the reaction, seriousness of the reaction, type of contrast media exposure, system organ class (SOC) affected (as described in World Health Organization Adverse Reaction Terminology [WHO-ART]) and outcome. Of the total 59,915 ICSRs in the database, 415 (0.7%) were suspected adverse reactions to contrast media; 44 reports were serious, including three fatal cases. The most affected SOCs were skin and appendage disorders, body as a whole-general disorders, gastrointestinal system disorders and respiratory system disorders. Hypersensitivity reactions were reported in the majority of ICSRs. The contrast media with the highest number of reports were iohexol (40.7%), iomeprol (17.8%), iopamidol (12%) and diatrizoate (12%). Most of the reactions to contrast media were allergic-like, and no previously unrecognised adverse reactions were observed in the Indian population. Further data and increased awareness among healthcare professionals is required to signal and prevent the consequences of adverse reactions attributed to contrast media.

  5. Usefulness of high-density barium for detection of leaks after esophagogastrectomy, total gastrectomy, and total laryngectomy.

    PubMed

    Swanson, Jonathan O; Levine, Marc S; Redfern, Regina O; Rubesin, Stephen E

    2003-08-01

    The purpose of this study was to determine the usefulness of a high-density (250% weight/volume) barium compared with a water-soluble contrast agent for the detection of esophageal leaks in patients who had undergone esophagogastrectomy, total gastrectomy, or total laryngectomy. A search of our radiology database from 1998 to 2001 revealed 46 eligible radiographic studies performed using a water-soluble contrast agent alone or a water-soluble contrast agent followed by barium that showed leaks in patients who had undergone esophagogastrectomy, total gastrectomy, or total laryngectomy. The images were reviewed to determine the morphology of the leaks (i.e., blind-ending tracks, sealed-off collections, or free extravasation of contrast material). Medical records were also reviewed to determine whether detection of the leaks seen on the radiographic studies affected patient management. Of the 46 leaks seen on radiographic studies, 23 (50%) were detected with a water-soluble contrast agent and 23 (50%) were detected only with high-density barium. Of the 23 leaks visualized with water-soluble contrast media, six (26%) were characterized by blind-ending tracks, 14 (61%) by sealed-off collections, and three (13%) by free extravasation of contrast material into the mediastinum or neck. Of the 23 leaks visualized only with high-density barium, 19 (83%) were characterized by blind-ending tracks and four (17%) by sealed-off collections. Thus, leaks detected only on images obtained with high-density barium were significantly more likely to be characterized by blind-ending tracks than those detected on images obtained with a water-soluble contrast agent (p = 0.0007). Of the 33 patients with clinical follow-up, the findings seen on these imaging studies affected management in 12 (86%) of 14 patients with leaks depicted by water-soluble contrast media and in 10 (53%) of 19 with leaks depicted only by high-density barium. Our findings support the use of high-density barium as part of the routine postoperative radiographic examination when no leaks are detected on images obtained with a water-soluble contrast agent.

  6. Meta-analysis of oral water-soluble contrast agent in the management of adhesive small bowel obstruction.

    PubMed

    Abbas, S M; Bissett, I P; Parry, B R

    2007-04-01

    Adhesions are the leading cause of small bowel obstruction. Identification of patients who require surgery is difficult. This review analyses the role of Gastrografin as a diagnostic and therapeutic agent in the management of adhesive small bowel obstruction. A systematic search of Medline, Embase and Cochrane databases was performed to identify studies of the use of Gastrografin in adhesive small bowel obstruction. Studies that addressed the diagnostic role of water-soluble contrast agent were appraised, and data presented as sensitivity, specificity, and positive and negative likelihood ratios. Results were pooled and a summary receiver-operator characteristic (ROC) curve was constructed. A meta-analysis of the data from six therapeutic studies was performed using the Mantel-Haenszel test and both fixed- and random-effect models. The appearance of water-soluble contrast agent in the colon on an abdominal radiograph within 24 h of its administration predicted resolution of obstruction with a pooled sensitivity of 97 per cent and specificity of 96 per cent. The area under the summary ROC curve was 0.98. Water-soluble contrast agent did not reduce the need for surgical intervention (odds ratio 0.81, P = 0.300), but it did reduce the length of hospital stay for patients who did not require surgery compared with placebo (weighted mean difference--1.84 days; P < 0.001). Published data strongly support the use of water-soluble contrast medium as a predictive test for non-operative resolution of adhesive small bowel obstruction. Although Gastrografin does not reduce the need for operation, it appears to shorten the hospital stay for those who do not require surgery.

  7. Use of positive oral contrast agents in abdominopelvic computed tomography for blunt abdominal injury: meta-analysis and systematic review.

    PubMed

    Lee, Chau Hung; Haaland, Benjamin; Earnest, Arul; Tan, Cher Heng

    2013-09-01

    To determine whether positive oral contrast agents improve accuracy of abdominopelvic CT compared with no, neutral or negative oral contrast agent. Literature was searched for studies evaluating the diagnostic performance of abdominopelvic CT with positive oral contrast agents against imaging with no, neutral or negative oral contrast agent. Meta-analysis reviewed studies correlating CT findings of blunt abdominal injury with positive and without oral contrast agents against surgical, autopsy or clinical outcome allowing derivation of pooled sensitivity and specificity. Systematic review was performed on studies with common design and reference standard. Thirty-two studies were divided into two groups. Group 1 comprised 15 studies comparing CT with positive and without oral contrast agents. Meta-analysis of five studies from group 1 provided no difference in sensitivity or specificity between CT with positive or without oral contrast agents. Group 2 comprised 17 studies comparing CT with positive and neutral or negative oral contrast agents. Systematic review of 12 studies from group 2 indicated that neutral or negative oral contrasts were as effective as positive oral contrast agents for bowel visualisation. There is no difference in accuracy between CT performed with positive oral contrast agents or with no, neutral or negative oral contrast agent. • There is no difference in the accuracy of CT with or without oral contrast agent. • There is no difference in the accuracy of CT with Gastrografin or water. • Omission of oral contrast, utilising neutral or negative oral contrast agent saves time, costs and decreases risk of aspiration.

  8. Method and apparatus to characterize ultrasonically reflective contrast agents

    NASA Technical Reports Server (NTRS)

    Pretlow, Robert A., III (Inventor)

    1993-01-01

    A method and apparatus for characterizing the time and frequency response of an ultrasonically reflective contrast agent is disclosed. An ultrasonically reflective contrast agent is injected, under constant pressure, into a fluid flowing through a pump flow circuit. The fluid and the ultrasonically reflective contrast agent are uniformly mixed in a mixing chamber, and the uniform mixture is passed through a contrast agent chamber. The contrast agent chamber is acoustically and axially interposed between an ultrasonic transducer chamber and an acoustic isolation chamber. A pulse of ultrasonic energy is transmitted into the contrast agent chamber from the ultrasonic transducer chamber. An echo waveform is received from the ultrasonically reflective contrast agent, and it is analyzed to determine the time and frequency response of the ultrasonically reflective contrast agent.

  9. A New Approach To Secure Federated Information Bases Using Agent Technology.

    ERIC Educational Resources Information Center

    Weippi, Edgar; Klug, Ludwig; Essmayr, Wolfgang

    2003-01-01

    Discusses database agents which can be used to establish federated information bases by integrating heterogeneous databases. Highlights include characteristics of federated information bases, including incompatible database management systems, schemata, and frequently changing context; software agent technology; Java agents; system architecture;…

  10. Advances in Magnetic Resonance Imaging Contrast Agents for Biomarker Detection

    PubMed Central

    Sinharay, Sanhita; Pagel, Mark D.

    2016-01-01

    Recent advances in magnetic resonance imaging (MRI) contrast agents have provided new capabilities for biomarker detection through molecular imaging. MRI contrast agents based on the T2 exchange mechanism have more recently expanded the armamentarium of agents for molecular imaging. Compared with T1 and T2* agents, T2 exchange agents have a slower chemical exchange rate, which improves the ability to design these MRI contrast agents with greater specificity for detecting the intended biomarker. MRI contrast agents that are detected through chemical exchange saturation transfer (CEST) have even slower chemical exchange rates. Another emerging class of MRI contrast agents uses hyperpolarized 13C to detect the agent with outstanding sensitivity. These hyperpolarized 13C agents can be used to track metabolism and monitor characteristics of the tissue microenvironment. Together, these various MRI contrast agents provide excellent opportunities to develop molecular imaging for biomarker detection. PMID:27049630

  11. Iodinated contrast media and contrast-induced nephropathy: is there a preferred cost-effective agent?

    PubMed

    Sharma, Samin K

    2008-05-01

    Over 20 years have passed since the introduction of the tri-iodinated low-osmolar nonionic contrast agents such as iopamidol, iohexol, ioversol and iopromide. During this time, most cardiology practices have switched to these nonionic agents to avoid the nuisance side effects and cardiac adverse events associated with the older ionic contrast agents. Although the improved tolerability of the nonionic agents is generally attributed to their decreased osmolality (approximately half that of the older ionic contrast agents), in fact, these contrast agents also differ from the older agents in their ionicity, viscosity and direct chemotoxicity. The impact of these properties on safety, together with cost differences, should be considered when selecting a contrast agent.

  12. [Utilization of polymeric micelle magnetic resonance imaging (MRI) contrast agent for theranostic system].

    PubMed

    Shiraishi, Kouichi

    2013-01-01

    We applied a polymeric micelle carrier system for the targeting of a magnetic resonance imaging (MRI) contrast agent. Prepared polymeric micelle MRI contrast agent exhibited a long circulation characteristic in blood, and considerable amount of the contrast agent was found to accumulate in colon 26 solid tumor by the EPR effect. The signal intensities of tumor area showed 2-folds increase in T1-weighted images at 24 h after i.v. injection. To observe enhancement of the EPR effect by Cderiv pretreatment on tumor targeting, we used the contrast agent for the evaluation by means of MRI. Cderiv pretreatment significantly enhanced tumor accumulation of the contrast agent. Interestingly, very high signal intensity in tumor region was found at 24 h after the contrast agent injection in Cderiv pretreated mice. The contrast agent visualized a microenvironmental change in tumor. These results indicate that the contrast agent exhibits potential use for tumor diagnostic agent. To combine with a polymeric micelle carrier system for therapeutic agent, the usage of the combination makes a new concept of "theranostic" for a better cancer treatment.

  13. The California Oak Disease and Arthropod (CODA) Database

    Treesearch

    Tedmund J. Swiecki; Elizabeth A. Bernhardt; Richard A. Arnold

    1997-01-01

    The California Oak Disease and Arthropod (CODA) host index database is a compilation of information on agents that colonize or feed on oaks in California. Agents in the database include plant-feeding insects and mites, nematodes, microorganisms, viruses, and abiotic disease agents. CODA contains summarized information on hosts, agents, information sources, and the...

  14. Dual Contrast - Magnetic Resonance Fingerprinting (DC-MRF): A Platform for Simultaneous Quantification of Multiple MRI Contrast Agents.

    PubMed

    Anderson, Christian E; Donnola, Shannon B; Jiang, Yun; Batesole, Joshua; Darrah, Rebecca; Drumm, Mitchell L; Brady-Kalnay, Susann M; Steinmetz, Nicole F; Yu, Xin; Griswold, Mark A; Flask, Chris A

    2017-08-16

    Injectable Magnetic Resonance Imaging (MRI) contrast agents have been widely used to provide critical assessments of disease for both clinical and basic science imaging research studies. The scope of available MRI contrast agents has expanded over the years with the emergence of molecular imaging contrast agents specifically targeted to biological markers. Unfortunately, synergistic application of more than a single molecular contrast agent has been limited by MRI's ability to only dynamically measure a single agent at a time. In this study, a new Dual Contrast - Magnetic Resonance Fingerprinting (DC - MRF) methodology is described that can detect and independently quantify the local concentration of multiple MRI contrast agents following simultaneous administration. This "multi-color" MRI methodology provides the opportunity to monitor multiple molecular species simultaneously and provides a practical, quantitative imaging framework for the eventual clinical translation of molecular imaging contrast agents.

  15. Almost human: Anthropomorphism increases trust resilience in cognitive agents.

    PubMed

    de Visser, Ewart J; Monfort, Samuel S; McKendrick, Ryan; Smith, Melissa A B; McKnight, Patrick E; Krueger, Frank; Parasuraman, Raja

    2016-09-01

    We interact daily with computers that appear and behave like humans. Some researchers propose that people apply the same social norms to computers as they do to humans, suggesting that social psychological knowledge can be applied to our interactions with computers. In contrast, theories of human–automation interaction postulate that humans respond to machines in unique and specific ways. We believe that anthropomorphism—the degree to which an agent exhibits human characteristics—is the critical variable that may resolve this apparent contradiction across the formation, violation, and repair stages of trust. Three experiments were designed to examine these opposing viewpoints by varying the appearance and behavior of automated agents. Participants received advice that deteriorated gradually in reliability from a computer, avatar, or human agent. Our results showed (a) that anthropomorphic agents were associated with greater trust resilience , a higher resistance to breakdowns in trust; (b) that these effects were magnified by greater uncertainty; and c) that incorporating human-like trust repair behavior largely erased differences between the agents. Automation anthropomorphism is therefore a critical variable that should be carefully incorporated into any general theory of human–agent trust as well as novel automation design. PsycINFO Database Record (c) 2016 APA, all rights reserved

  16. Ultrasound Contrast Agents

    NASA Astrophysics Data System (ADS)

    Cachard, Christian; Basset, Olivier

    While the use of contrast agents in other imaging modalities (X ray, MRI, PET, …) has been routinely accepted for many years, the development and commercialization of contrast agents designed specifically for ultrasound imaging has occurred only very recently. As in the other imaging modalities, the injection of contrast agents during an ultrasound examination is intended to facilitate the detection and diagnosis of specific pathologies. Contrast agents efficiency is based on the backscattering of ultrasound by microbubbles. These microparticules are intravenously injected in the blood flow. After an introduction and generalities on ultrasound contrast agents (UCA) the microbubble physics in an acoustic field will be developed. Second, physics characteristics of contrast agents will be compared (bubbles with or without shell, gas nature, size distribution). Influence of acoustic pressure on the behaviour of the microparticules (linear, non linear and destruction) will be discussed. Finally, a review of specific imaging adapted to contrast agent properties as harmonic imaging, pulse inversion imaging will be presented.

  17. Human health risk assessment database, "the NHSRC toxicity value database": supporting the risk assessment process at US EPA's National Homeland Security Research Center.

    PubMed

    Moudgal, Chandrika J; Garrahan, Kevin; Brady-Roberts, Eletha; Gavrelis, Naida; Arbogast, Michelle; Dun, Sarah

    2008-11-15

    The toxicity value database of the United States Environmental Protection Agency's (EPA) National Homeland Security Research Center has been in development since 2004. The toxicity value database includes a compilation of agent property, toxicity, dose-response, and health effects data for 96 agents: 84 chemical and radiological agents and 12 biotoxins. The database is populated with multiple toxicity benchmark values and agent property information from secondary sources, with web links to the secondary sources, where available. A selected set of primary literature citations and associated dose-response data are also included. The toxicity value database offers a powerful means to quickly and efficiently gather pertinent toxicity and dose-response data for a number of agents that are of concern to the nation's security. This database, in conjunction with other tools, will play an important role in understanding human health risks, and will provide a means for risk assessors and managers to make quick and informed decisions on the potential health risks and determine appropriate responses (e.g., cleanup) to agent release. A final, stand alone MS ACESSS working version of the toxicity value database was completed in November, 2007.

  18. Gadolinium-Based Contrast Agents for MR Cancer Imaging

    PubMed Central

    Zhou, Zhuxian; Lu, Zheng-Rong

    2013-01-01

    Magnetic resonance imaging (MRI) is a clinical imaging modality effective for anatomical and functional imaging of diseased soft tissues, including solid tumors. MRI contrast agents have been routinely used for detecting tumor at an early stage. Gadolinium based contrast agents are the most commonly used contrast agents in clinical MRI. There have been significant efforts to design and develop novel Gd(III) contrast agents with high relaxivity, low toxicity and specific tumor binding. The relaxivity of the Gd(III) contrast agents can be increased by proper chemical modification. The toxicity of Gd(III) contrast agents can be reduced by increasing the agents’ thermodynamic and kinetic stability, as well as optimizing their pharmacokinetic properties. The increasing knowledge in the field of cancer genomics and biology provides an opportunity for designing tumor-specific contrast agents. Various new Gd(III) chelates have been designed and evaluated in animal models for more effective cancer MRI. This review outlines the design and development, physicochemical properties, and in vivo properties of several classes of Gd(III)-based MR contrast agents for tumor imaging. PMID:23047730

  19. Integrin Targeted MR Imaging

    PubMed Central

    Tan, Mingqian; Lu, Zheng-Rong

    2011-01-01

    Magnetic resonance imaging (MRI) is a powerful medical diagnostic imaging modality for integrin targeted imaging, which uses the magnetic resonance of tissue water protons to display tissue anatomic structures with high spatial resolution. Contrast agents are often used in MRI to highlight specific regions of the body and make them easier to visualize. There are four main classes of MRI contrast agents based on their different contrast mechanisms, including T1, T2, chemical exchange saturation transfer (CEST) agents, and heteronuclear contrast agents. Integrins are an important family of heterodimeric transmembrane glycoproteins that function as mediators of cell-cell and cell-extracellular matrix interactions. The overexpressed integrins can be used as the molecular targets for designing suitable integrin targeted contrast agents for MR molecular imaging. Integrin targeted contrast agent includes a targeting agent specific to a target integrin, a paramagnetic agent and a linker connecting the targeting agent with the paramagnetic agent. Proper selection of targeting agents is critical for targeted MRI contrast agents to effectively bind to integrins for in vivo imaging. An ideal integrin targeted MR contrast agent should be non-toxic, provide strong contrast enhancement at the target sites and can be completely excreted from the body after MR imaging. An overview of integrin targeted MR contrast agents based on small molecular and macromolecular Gd(III) complexes, lipid nanoparticles and superparamagnetic nanoparticles is provided for MR molecular imaging. By using proper delivery systems for loading sufficient Gd(III) chelates or superparamagnetic nanoparticles, effective molecular imaging of integrins with MRI has been demonstrated in animal models. PMID:21547154

  20. Systematic review and meta-analysis of the diagnostic and therapeutic role of water-soluble contrast agent in adhesive small bowel obstruction.

    PubMed

    Branco, B C; Barmparas, G; Schnüriger, B; Inaba, K; Chan, L S; Demetriades, D

    2010-04-01

    This meta-analysis assessed the diagnostic and therapeutic role of water-soluble contrast agent (WSCA) in adhesive small bowel obstruction (SBO). PubMed, Embase and Cochrane databases were searched systematically. The primary outcome in the diagnostic role of WSCA was its ability to predict the need for surgery. In the therapeutic role, the following were evaluated: resolution of SBO without surgery, time from admission to resolution, duration of hospital stay, complications and mortality. To assess the diagnostic role of WSCA, pooled estimates of sensitivity, specificity, positive and negative predictive values, and likelihood ratios were derived. For the therapeutic role of WSCA, weighted odds ratio (OR) and weighted mean difference (WMD) were obtained. Fourteen prospective studies were included. The appearance of contrast in the colon within 4-24 h after administration had a sensitivity of 96 per cent and specificity of 98 per cent in predicting resolution of SBO. WSCA administration was effective in reducing the need for surgery (OR 0.62; P = 0.007) and shortening hospital stay (WMD -1.87 days; P < 0.001) compared with conventional treatment. Water-soluble contrast was effective in predicting the need for surgery in patients with adhesive SBO. In addition, it reduced the need for operation and shortened hospital stay. Copyright (c) 2010 British Journal of Surgery Society Ltd. Published by John Wiley & Sons, Ltd.

  1. Nanodiamond-Manganese dual mode MRI contrast agents for enhanced liver tumor detection.

    PubMed

    Hou, Weixin; Toh, Tan Boon; Abdullah, Lissa Nurrul; Yvonne, Tay Wei Zheng; Lee, Kuan J; Guenther, Ilonka; Chow, Edward Kai-Hua

    2017-04-01

    Contrast agent-enhanced magnetic resonance (MR) imaging is critical for the diagnosis and monitoring of a number of diseases, including cancer. Certain clinical applications, including the detection of liver tumors, rely on both T1 and T2-weighted images even though contrast agent-enhanced MR imaging is not always reliable. Thus, there is a need for improved dual mode contrast agents with enhanced sensitivity. We report the development of a nanodiamond-manganese dual mode contrast agent that enhanced both T1 and T2-weighted MR imaging. Conjugation of manganese to nanodiamonds resulted in improved longitudinal and transverse relaxivity efficacy over unmodified MnCl 2 as well as clinical contrast agents. Following intravenous administration, nanodiamond-manganese complexes outperformed current clinical contrast agents in an orthotopic liver cancer mouse model while also reducing blood serum concentration of toxic free Mn 2+ ions. Thus, nanodiamond-manganese complexes may serve as more effective dual mode MRI contrast agent, particularly in cancer. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Contrast enhanced spectroscopic optical coherence tomography

    NASA Technical Reports Server (NTRS)

    Xu, Chenyang (Inventor); Boppart, Stephen A. (Inventor)

    2010-01-01

    A method of forming an image of a sample includes performing SOCT on a sample. The sample may include a contrast agent, which may include an absorbing agent and/or a scattering agent. A method of forming an image of tissue may include selecting a contrast agent, delivering the contrast agent to the tissue, acquiring SOCT data from the tissue, and converting the SOCT data into an image. The contributions to the SOCT data of an absorbing agent and a scattering agent in a sample may be quantified separately.

  3. Blood-pool contrast agent for pre-clinical computed tomography

    NASA Astrophysics Data System (ADS)

    Cruje, Charmainne; Tse, Justin J.; Holdsworth, David W.; Gillies, Elizabeth R.; Drangova, Maria

    2017-03-01

    Advances in nanotechnology have led to the development of blood-pool contrast agents for micro-computed tomography (micro-CT). Although long-circulating nanoparticle-based agents exist for micro-CT, they are predominantly based on iodine, which has a low atomic number. Micro-CT contrast increases when using elements with higher atomic numbers (i.e. lanthanides), particularly at higher energies. The purpose of our work was to develop and evaluate a lanthanide-based blood-pool contrast agent that is suitable for in vivo micro-CT. We synthesized a contrast agent in the form of polymer-encapsulated Gd nanoparticles and evaluated its stability in vitro. The synthesized nanoparticles were shown to have an average diameter of 127 +/- 6 nm, with good size dispersity. Particle size distribution - evaluated by dynamic light scattering over the period of two days - demonstrated no change in size of the contrast agent in water and saline. Additionally, our contrast agent was stable in a mouse serum mimic for up to 30 minutes. CT images of the synthesized contrast agent (containing 27 mg/mL of Gd) demonstrated an attenuation of over 1000 Hounsfield Units. This approach to synthesizing a Gd-based blood-pool contrast agent promises to enhance the capabilities of micro-CT imaging.

  4. Nanoparticle Contrast Agents for Computed Tomography: A Focus on Micelles

    PubMed Central

    Cormode, David P.; Naha, Pratap C.; Fayad, Zahi A.

    2014-01-01

    Computed tomography (CT) is an X-ray based whole body imaging technique that is widely used in medicine. Clinically approved contrast agents for CT are iodinated small molecules or barium suspensions. Over the past seven years there has been a great increase in the development of nanoparticles as CT contrast agents. Nanoparticles have several advantages over small molecule CT contrast agents, such as long blood-pool residence times, and the potential for cell tracking and targeted imaging applications. Furthermore, there is a need for novel CT contrast agents, due to the growing population of renally impaired patients and patients hypersensitive to iodinated contrast. Micelles and lipoproteins, a micelle-related class of nanoparticle, have notably been adapted as CT contrast agents. In this review we discuss the principles of CT image formation and the generation of CT contrast. We discuss the progress in developing non-targeted, targeted and cell tracking nanoparticle CT contrast agents. We feature agents based on micelles and used in conjunction with spectral CT. The large contrast agent doses needed will necessitate careful toxicology studies prior to clinical translation. However, the field has seen tremendous advances in the past decade and we expect many more advances to come in the next decade. PMID:24470293

  5. Biocompatible KMnF3 nanoparticular contrast agent with proper plasma retention time for in vivo magnetic resonance imaging.

    PubMed

    Liu, Zhi-jun; Song, Xiao-xia; Xu, Xian-zhu; Tang, Qun

    2014-04-18

    Nanoparticular MRI contrast agents are rapidly becoming suitable for use in clinical diagnosis. An ideal nanoparticular contrast agent should be endowed with high relaxivity, biocompatibility, proper plasma retention time, and tissue-specific or tumor-targeting imaging. Herein we introduce PEGylated KMnF3 nanoparticles as a new type of T1 contrast agent. Studies showed that the nanoparticular contrast agent revealed high bio-stability with bovine serum albumin in PBS buffer solution, and presented excellent biocompatibility (low cytotoxicity, undetectable hemolysis and hemagglutination). Meanwhile the new contrast agent possessed proper plasma retention time (circulation half-life t1/2 is approximately 2 h) in the body of the administrated mice. It can be delivered into brain vessels and maintained there for hours, and is mostly cleared from the body within 48 h, as demonstrated by time-resolved MRI and Mn-biodistribution analysis. Those distinguishing features make it suitable to obtain contrast-enhanced brain magnetic resonance angiography. Moreover, through the process of passive targeting delivery, the T1 contrast agent clearly illuminates a brain tumor (glioma) with high contrast image and defined shape. This study demonstrates that PEGylated KMnF3 nanoparticles represent a promising biocompatible vascular contrast agent for magnetic resonance angiography and can potentially be further developed into an active targeted tumor MRI contrast agent.

  6. Dual energy CT: How well can pseudo-monochromatic imaging reduce metal artifacts?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuchenbecker, Stefan, E-mail: stefan.kuchenbecker@dkfz.de; Faby, Sebastian; Sawall, Stefan

    2015-02-15

    Purpose: Dual Energy CT (DECT) provides so-called monoenergetic images based on a linear combination of the original polychromatic images. At certain patient-specific energy levels, corresponding to certain patient- and slice-dependent linear combination weights, e.g., E = 160 keV corresponds to α = 1.57, a significant reduction of metal artifacts may be observed. The authors aimed at analyzing the method for its artifact reduction capabilities to identify its limitations. The results are compared with raw data-based processing. Methods: Clinical DECT uses a simplified version of monochromatic imaging by linearly combining the low and the high kV images and by assigning an energymore » to that linear combination. Those pseudo-monochromatic images can be used by radiologists to obtain images with reduced metal artifacts. The authors analyzed the underlying physics and carried out a series expansion of the polychromatic attenuation equations. The resulting nonlinear terms are responsible for the artifacts, but they are not linearly related between the low and the high kV scan: A linear combination of both images cannot eliminate the nonlinearities, it can only reduce their impact. Scattered radiation yields additional noncanceling nonlinearities. This method is compared to raw data-based artifact correction methods. To quantify the artifact reduction potential of pseudo-monochromatic images, they simulated the FORBILD abdomen phantom with metal implants, and they assessed patient data sets of a clinical dual source CT system (100, 140 kV Sn) containing artifacts induced by a highly concentrated contrast agent bolus and by metal. In each case, they manually selected an optimal α and compared it to a raw data-based material decomposition in case of simulation, to raw data-based material decomposition of inconsistent rays in case of the patient data set containing contrast agent, and to the frequency split normalized metal artifact reduction in case of the metal implant. For each case, the contrast-to-noise ratio (CNR) was assessed. Results: In the simulation, the pseudo-monochromatic images yielded acceptable artifact reduction results. However, the CNR in the artifact-reduced images was more than 60% lower than in the original polychromatic images. In contrast, the raw data-based material decomposition did not significantly reduce the CNR in the virtual monochromatic images. Regarding the patient data with beam hardening artifacts and with metal artifacts from small implants the pseudo-monochromatic method was able to reduce the artifacts, again with the downside of a significant CNR reduction. More intense metal artifacts, e.g., as those caused by an artificial hip joint, could not be suppressed. Conclusions: Pseudo-monochromatic imaging is able to reduce beam hardening, scatter, and metal artifacts in some cases but it cannot remove them. In all cases, the CNR is significantly reduced, thereby rendering the method questionable, unless special post processing algorithms are implemented to restore the high CNR from the original images (e.g., by using a frequency split technique). Raw data-based dual energy decomposition methods should be preferred, in particular, because the CNR penalty is almost negligible.« less

  7. Assessment of MRI Contrast Agent Kinetics via Retro-Orbital Injection in Mice: Comparison with Tail Vein Injection.

    PubMed

    Wang, Fang; Nojima, Masanori; Inoue, Yusuke; Ohtomo, Kuni; Kiryu, Shigeru

    2015-01-01

    It is not known whether administration of contrast agent via retro-orbital injection or the tail vein route affects the efficiency of dynamic contrast-enhanced magnetic resonance imaging (MRI). Therefore, we compared the effects of retro-orbital and tail vein injection on the kinetics of the contrast agent used for MRI in mice. The same group of nine healthy female mice received contrast agent via either route. An extracellular contrast agent was infused via the tail vein and retro-orbital vein, in random order. Dynamic contrast-enhanced MRI was performed before and after administering the contrast agent. The contrast effects in the liver, kidney, lung, and myocardium were assessed. The average total times of venous puncture and mounting of the injection system were about 10 and 4 min for the tail vein and retro-orbital route, respectively. For all organs assessed, the maximum contrast ratio occurred 30 s after administration and the time course of the contrast ratio was similar with either routes. For each organ, the contrast ratios correlated strongly; the contrast ratios were similar. The retro-orbital and tail vein routes afforded similar results in terms of the kinetics of the contrast agent. The retro-orbital route can be used as a simple efficient alternative to tail vein injection for dynamic contrast-enhanced MRI of mice.

  8. Ferrimagnetic susceptibility contrast agents.

    PubMed

    Bach-Gansmo, T

    1993-01-01

    Contrast agents based on superparamagnetic particles have been in clinical development for more than 5 years, and the complexity of their effects is still not elucidated. The relaxivities are frequently used to give an idea of their efficacy, but these parameters can only be used if they are concentration independent. For large superparamagnetic systems, the evolution of the transverse magnetization is biexponential, after an initial loss of magnetization. Both these characteristics of large superparamagnetic systems should lead to prudence in using the relaxivities as indicators of contrast medium efficacy. Susceptibility induced artefacts have been associated with the use of superparamagnetic contrast agents since the first imaging evaluation took place. The range of concentrations where good contrast effect was achieved without inducing artefacts, as well as blurring and metal artefacts were evaluated. The influence of motion on the induction of artefacts was studied, and compared to the artefacts induced by a paramagnetic agent subject to motion. With a suitable concentration of a negative contrast agent, a signal void could be achieved in the region prone to motion, and no artefacts were induced. If the concentration was too high, a displacement of the region close to the contrast agent was observed. The artefacts occurred in a volume surrounding the contrast agent, i.e., also outside the imaging plane. In comparison a positive, paramagnetic contrast agent induced heavy artefacts in the phase encoding direction, appearing as both high intensity regions and black holes, in a mosaic pattern. Clinical trials of the oral contrast agent OMP for abdominal MR imaging showed this agent to be safe and efficacious. OMP increased the diagnostic efficacy of abdominal MR imaging in 2 of 3 cases examined, with a significant decrease in motion artefacts. Susceptibility contrast agents may also be of use in the evaluation of small lesions in the liver. Particulate material injected i.v. will be targeted to the liver and spleen by way of the mononuclear phagocyte system (MPS). Small particles, without specific receptor affinities were targeted to the hepatocytes and the MPS. The distribution correlated with a high efficiency as a contrast agent, whereas no correlation to in vitro relaxation rates and relaxivities could be found. Superparamagnetic particles have important possibilities as contrast agents. The identification of in vitro properties of these agents may help the comparison of various agents before in vivo imaging.

  9. Functional Nanoparticles for Magnetic Resonance Imaging

    PubMed Central

    Mao, Xinpei; Xu, Jiadi; Cui, Honggang

    2016-01-01

    Nanoparticle-based magnetic resonance imaging (MRI) contrast agents have received much attention over the past decade. By virtue of a high payload of magnetic moieties, enhanced accumulation at disease sites, and a large surface area for additional modification with targeting ligands, nanoparticle-based contrast agents offer promising new platforms to further enhance the high resolution and sensitivity of MRI for various biomedical applications. T2* superparamagnetic iron oxide nanoparticles (SPIONs) first demonstrated superior improvement on MRI sensitivity. The prevailing SPION attracted growing interest in the development of refined nanoscale versions of MRI contrast agents. Afterwards, T1-based contrast agents were developed, and became the most studied subject in MRI due to the positive contrast they provide that avoids the susceptibility associated with MRI signal reduction. Recently, chemical exchange saturation transfer (CEST) contrast agents have emerged and rapidly gained popularity. The unique aspect of CEST contrast agents is that their contrast can be selectively turned “on” and “off” by radiofrequency (RF) saturation. Their performance can be further enhanced by incorporating a large number of exchangeable protons into well-defined nanostructure. Besides activatable CEST contrast agents, there is growing interest in developing nanoparticle-based activatable MRI contrast agents responsive to stimuli (pH, enzyme, etc.), which improves sensitivity and specificity. In this review, we summarize the recent development of various types of nanoparticle-based MRI contrast agents, and have focused our discussions on the key advantages of introducing nanoparticles in MRI. PMID:27040463

  10. Synthetic Ni3S2/Ni hybrid architectures as potential contrast agents in MRI

    NASA Astrophysics Data System (ADS)

    Ma, J.; Chen, K.

    2016-04-01

    Traditional magnetic resonance imaging (MRI) contrast agents mainly include superparamagnetic (SPM) iron oxide nanoparticle as T 2 contrast agent for liver and paramagnetic Gd (III)-chelate as T 1 contrast agent for all organs. In this work, weak ferromagnetic kale-like and SPM cabbage-like Ni3S2@Ni hybrid architectures were synthesized and evaluated as potential T 1 MRI contrast agents. Their relatively small r 2/r 1 ratios of 2.59 and 2.38, and high r 1 values of 11.27 and 4.89 mmol-1 L s-1 (for the kale-like and cabbage-like Ni3S2@Ni, respectively) will shed some light on the development of new-type MRI contrast agents.

  11. Gadolinium-enhanced MR images of the growing piglet skeleton: ionic versus nonionic contrast agent.

    PubMed

    Menezes, Nina M; Olear, Elizabeth A; Li, Xiaoming; Connolly, Susan A; Zurakowski, David; Foley, Mary; Shapiro, Frederic; Jaramillo, Diego

    2006-05-01

    To determine whether there are differences in the distribution of ionic and nonionic gadolinium-based contrast agents by evaluating contrast enhancement of the physis, epiphyseal cartilage, secondary ossification center, and metaphysis in the knees of normal piglets. Following approval from the Subcommittee on Research Animal Care, knees of 12 3-week-old piglets were imaged at 3-T magnetic resonance (MR) imaging after intravenous injection of gadoteridol (nonionic contrast agent; n = 6) or gadopentetate dimeglumine (ionic contrast agent; n = 6). Early enhancement evaluation with gradient-echo MR imaging was quantified and compared (Student t test) by means of enhancement ratios. Distribution of contrast material was assessed and compared (Student t test) by means of T1 measurements obtained before and at three 15-minute intervals after contrast agent administration. The relative visibility of the physis, epiphyseal cartilage, secondary ossification center, and metaphysis was qualitatively assessed by two observers and compared (Wilcoxon signed rank test). Differences in matrix content and cellularity that might explain the imaging findings were studied at histologic evaluation. Enhancement ratios were significantly higher for gadoteridol than for gadopentetate dimeglumine in the physis, epiphyseal cartilage, and secondary ossification center (P < .05). After contrast agent administration, T1 values decreased sharply for both agents-but more so for gadoteridol. Additionally, there was less variability in T1 values across structures with this contrast agent. Gadoteridol resulted in greater visibility of the physis, while gadopentetate dimeglumine resulted in greater contrast between the physis and metaphysis (P < .05). The results suggest different roles for the two gadolinium-based contrast agents: The nonionic contrast medium is better suited for evaluating perfusion and anatomic definition in the immature skeleton, while the ionic contrast medium is better for evaluating cartilage fixed-charge density. (c) RSNA, 2006.

  12. Vascular applications of contrast-enhanced ultrasound imaging.

    PubMed

    Mehta, Kunal S; Lee, Jake J; Taha, Ashraf G; Avgerinos, Efthymios; Chaer, Rabih A

    2017-07-01

    Contrast-enhanced ultrasound (CEUS) imaging is a powerful noninvasive modality offering numerous potential diagnostic and therapeutic applications in vascular medicine. CEUS imaging uses microbubble contrast agents composed of an encapsulating shell surrounding a gaseous core. These microbubbles act as nearly perfect intravascular reflectors of ultrasound energy and may be used to enhance the overall contrast and quality of ultrasound images. The purpose of this narrative review is to survey the current literature regarding CEUS imaging and discuss its diagnostic and therapeutic roles in current vascular and selected nonvascular applications. The PubMed, MEDLINE, and Embase databases were searched until July 2016 using the PubMed and Ovid Web-based search engines. The search terms used included contrast-enhanced, microbubble, ultrasound, carotid, aneurysm, and arterial. The diagnostic and therapeutic utility of CEUS imaging has grown exponentially, particularly in the realms of extracranial carotid arterial disease, aortic disease, and peripheral arterial disease. Studies have demonstrated that CEUS imaging is diagnostically superior to conventional ultrasound imaging in identifying vessel irregularities and measuring neovascularization to assess plaque vulnerability and end-muscle perfusion. Groups have begun to use microbubbles as agents in therapeutic applications for targeted drug and gene therapy delivery as well as for the enhancement of sonothrombolysis. The emerging technology of microbubbles and CEUS imaging holds considerable promise for cardiovascular medicine and cancer therapy given its diagnostic and therapeutic utility. Overall, with proper training and credentialing of technicians, the clinical implications are innumerable as microbubble technology is rapidly bursting onto the scene of cardiovascular medicine. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  13. Inorganic nanoparticle-based T1 and T1/T2 magnetic resonance contrast probes

    NASA Astrophysics Data System (ADS)

    Hu, Fengqin; Zhao, Yong Sheng

    2012-09-01

    Magnetic resonance imaging (MRI) yields high spatially resolved contrast with anatomical details for diagnosis, deeper penetration depth and rapid 3D scanning. To improve imaging sensitivity, adding contrast agents accelerates the relaxation rate of water molecules, thereby greatly increasing the contrast between specific issues or organs of interest. Currently, the majority of T1 contrast agents are paramagnetic molecular complexes, typically Gd(iii) chelates. Various nanoparticulate T1 and T1/T2 contrast agents have recently been investigated as novel agents possessing the advantages of both the T1 contrast effect and nanostructural characteristics. In this minireview, we describe the recent progress of these inorganic nanoparticle-based MRI contrast agents. Specifically, we mainly report on Gd and Mn-based inorganic nanoparticles and ultrasmall iron oxide/ferrite nanoparticles.

  14. Safety of Gadobutrol

    PubMed Central

    Endrikat, Jan; Vogtlaender, Kai; Dohanish, Susan; Balzer, Thomas; Breuer, Josy

    2016-01-01

    Objective The aim of this study was to provide a systematic safety analysis of gadobutrol after more than 29 million applications in clinical routine. Materials and Methods Forty-two clinical development phase II to IV studies on gadobutrol or comparator and the postmarketing safety surveillance database for gadobutrol (1998–2015) were analyzed. Adverse events (AEs) and drug-related AEs were evaluated in the clinical development database and spontaneous adverse drug reactions (ADRs) in the postmarketing database. Subgroup analyses were run on patients with special medical history and on patients of different age groups. Results In the clinical development studies, 6809 and 2184 patients received gadobutrol or comparators, respectively. The incidence of drug-related AEs was 3.5% for both groups. With the exception of nausea (0.7% related cases in both groups), all other drug-related AEs were 0.3% or less in both groups. Hypersensitivity reactions were sporadic (<0.1%). Patients with history of allergies to contrast agents experienced slightly more drug-related AEs. No differences were seen between age groups. The overall reporting rate of ADRs from postmarketing surveillance was 0.05%. The most frequent ADRs were anaphylactoid/hypersensitivity reactions, nausea, vomiting, and dyspnea. For 3 single-agent reports of nephrogenic systemic fibrosis, using a conservative approach, association with gadobutrol could not be excluded. Conclusions Gadobutrol is well tolerated and has a favorable safety profile for patients of all age groups. PMID:26964075

  15. K-edge ratio method for identification of multiple nanoparticulate contrast agents by spectral CT imaging

    PubMed Central

    Ghadiri, H; Ay, M R; Shiran, M B; Soltanian-Zadeh, H

    2013-01-01

    Objective: Recently introduced energy-sensitive X-ray CT makes it feasible to discriminate different nanoparticulate contrast materials. The purpose of this work is to present a K-edge ratio method for differentiating multiple simultaneous contrast agents using spectral CT. Methods: The ratio of two images relevant to energy bins straddling the K-edge of the materials is calculated using an analytic CT simulator. In the resulting parametric map, the selected contrast agent regions can be identified using a thresholding algorithm. The K-edge ratio algorithm is applied to spectral images of simulated phantoms to identify and differentiate up to four simultaneous and targeted CT contrast agents. Results: We show that different combinations of simultaneous CT contrast agents can be identified by the proposed K-edge ratio method when energy-sensitive CT is used. In the K-edge parametric maps, the pixel values for biological tissues and contrast agents reach a maximum of 0.95, whereas for the selected contrast agents, the pixel values are larger than 1.10. The number of contrast agents that can be discriminated is limited owing to photon starvation. For reliable material discrimination, minimum photon counts corresponding to 140 kVp, 100 mAs and 5-mm slice thickness must be used. Conclusion: The proposed K-edge ratio method is a straightforward and fast method for identification and discrimination of multiple simultaneous CT contrast agents. Advances in knowledge: A new spectral CT-based algorithm is proposed which provides a new concept of molecular CT imaging by non-iteratively identifying multiple contrast agents when they are simultaneously targeting different organs. PMID:23934964

  16. Gadolinium chloride as a contrast agent for imaging wood composite components by magnetic resonance

    Treesearch

    Thomas L. Eberhardt; Chi-Leung So; Andrea Protti; Po-Wah So

    2009-01-01

    Although paramagnetic contrast agents have an established track record in medical uses of magnetic resonance imaging (MRI), only recently has a contrast agent been used for enhancing MRI images of solid wood specimens. Expanding on this concept, wood veneers were treated with a gadolinium-based contrast agent and used in a model system comprising three-ply plywood...

  17. Contrast-enhanced voiding urosonography: in vitro evaluation of a second-generation ultrasound contrast agent for in vivo optimization.

    PubMed

    Back, Susan J; Edgar, J Christopher; Canning, Douglas A; Darge, Kassa

    2015-09-01

    Pediatric contrast-enhanced ultrasound (CEUS) is primarily performed outside the United States where a track record for safety in intravenous and intravesical applications has been established. Contrast-enhanced voiding urosonography (ceVUS) has also been shown to have a much higher rate of vesicoureteral reflux detection compared to voiding cystourethrography. US contrast agents available in the United States differ from those abroad. Optison® (GE Healthcare, Princeton, NJ) is such an US contrast agent. While Optison® has similar characteristics to other second-generation agents, it has never been used for ceVUS. In vitro optimization of dose and imaging parameters as well as assessment of contrast visualization when delivered in conditions similar to ceVUS are necessary starting points prior to in vivo applications. To optimize the intravesical use of Optison® in vitro for ceVUS before its use in pediatric studies. The experimental design simulated intravesical use. Using 9- and 12-MHz linear transducers, we scanned 20-mL syringes varying mechanical index, US contrast agent concentration (0.25%, 0.5%, 1.0%), solvent (saline, urine, radiographic contrast agent) and time out of refrigeration. We evaluated mechanical index settings and contrast duration, optimized the contrast dose, measured the effect of urine and radiographic contrast agent, and the impact of length of time of contrast outside of the refrigerator on US contrast appearance. We scanned 50-ml saline bags to assess the appearance and duration of US contrast with different delivery systems (injection vs. infusion). Consistent contrast visualization was achieved at a mechanical index of 0.06-0.17 and 0.11-0.48 for the L9 and L12 MHz transducers (P < 0.01), respectively. Thus, it was necessary to increase the mechanical index for better contrast visualization of the microbubbles with a higher transducer frequency. The lowest mechanical index for earliest visible microbubble destruction was 0.21 for the 9 MHz and 0.39 for the 12 MHz (P < 0.01) transducers. The 0.5% US contrast agent volume to bladder filling was the most optimal. At this concentration, the mean time to visualize homogenous contrast was 2 min and destruction of approximately half of the microbubbles in the field of view occurred in 7.8 min using the 9-MHz transducer. During contrast infusion, the contrast dose needed to be reduced to 0.12% for maintenance of optimal visualization of microbubbles. There was no deleterious effect on the visualization of contrast in the presence of urine or radiographic contrast agent. Infusion of the US contrast agent speeded visualization of homogeneous enhancement compared with injection. Time outside refrigeration did not affect contrast performance. Transducer mechanical index settings need to be optimized. A very low dose of the US contrast agent Optison® will suffice for intravesical application, i.e. 0.12% to 0.50% of the bladder filling volume. The presence of urine or radiographic contrast agent did not compromise contrast visualization. The best mode of administration is the infusion method due to fast homogenous distribution at the lowest dose of 0.12%. Leaving the US contrast agent outside the refrigerator for an hour does not affect the microbubbles.

  18. Model and reconstruction of a K-edge contrast agent distribution with an X-ray photon-counting detector

    PubMed Central

    Meng, Bo; Cong, Wenxiang; Xi, Yan; De Man, Bruno; Yang, Jian; Wang, Ge

    2017-01-01

    Contrast-enhanced computed tomography (CECT) helps enhance the visibility for tumor imaging. When a high-Z contrast agent interacts with X-rays across its K-edge, X-ray photoelectric absorption would experience a sudden increment, resulting in a significant difference of the X-ray transmission intensity between the left and right energy windows of the K-edge. Using photon-counting detectors, the X-ray intensity data in the left and right windows of the K-edge can be measured simultaneously. The differential information of the two kinds of intensity data reflects the contrast-agent concentration distribution. K-edge differences between various matters allow opportunities for the identification of contrast agents in biomedical applications. In this paper, a general radon transform is established to link the contrast-agent concentration to X-ray intensity measurement data. An iterative algorithm is proposed to reconstruct a contrast-agent distribution and tissue attenuation background simultaneously. Comprehensive numerical simulations are performed to demonstrate the merits of the proposed method over the existing K-edge imaging methods. Our results show that the proposed method accurately quantifies a distribution of a contrast agent, optimizing the contrast-to-noise ratio at a high dose efficiency. PMID:28437900

  19. Section 6—Mechanical Bioeffects in the Presence of Gas-Carrier Ultrasound Contrast Agents

    PubMed Central

    2007-01-01

    This review addresses the issue of mechanical ultrasound-induced bioeffects in the presence of gas carrier contrast agents (GCAs). Here, the term “contrast agent” refers to those agents that provide ultrasound contrast by being composed of microbubbles, encapsulated or not, containing one or more gases. Provided in this section are summaries on how contrast agents work, some of their current uses, and the potential for bio-effects associated with their presence in an ultrasonic field. PMID:10680618

  20. Basic MR relaxation mechanisms and contrast agent design.

    PubMed

    De León-Rodríguez, Luis M; Martins, André F; Pinho, Marco C; Rofsky, Neil M; Sherry, A Dean

    2015-09-01

    The diagnostic capabilities of magnetic resonance imaging (MRI) have undergone continuous and substantial evolution by virtue of hardware and software innovations and the development and implementation of exogenous contrast media. Thirty years since the first MRI contrast agent was approved for clinical use, a reliance on MR contrast media persists, largely to improve image quality with higher contrast resolution and to provide additional functional characterization of normal and abnormal tissues. Further development of MR contrast media is an important component in the quest for continued augmentation of diagnostic capabilities. In this review we detail the many important considerations when pursuing the design and use of MR contrast media. We offer a perspective on the importance of chemical stability, particularly kinetic stability, and how this influences one's thinking about the safety of metal-ligand-based contrast agents. We discuss the mechanisms involved in MR relaxation in the context of probe design strategies. A brief description of currently available contrast agents is accompanied by an in-depth discussion that highlights promising MRI contrast agents in the development of future clinical and research applications. Our intention is to give a diverse audience an improved understanding of the factors involved in developing new types of safe and highly efficient MR contrast agents and, at the same time, provide an appreciation of the insights into physiology and disease that newer types of responsive agents can provide. © 2015 Wiley Periodicals, Inc.

  1. "Basic MR Relaxation Mechanisms & Contrast Agent Design"

    PubMed Central

    De León-Rodríguez, Luis M.; Martins, André F.; Pinho, Marco; Rofsky, Neil; Sherry, A. Dean

    2015-01-01

    The diagnostic capabilities of magnetic resonance imaging (MRI) have undergone continuous and substantial evolution by virtue of hardware and software innovations and the development and implementation of exogenous contrast media. Thirty years since the first MRI contrast agent was approved for clinical use, a reliance on MR contrast media persists largely to improve image quality with higher contrast resolution and to provide additional functional characterization of normal and abnormal tissues. Further development of MR contrast media is an important component in the quest for continued augmentation of diagnostic capabilities. In this review we will detail the many important considerations when pursuing the design and use of MR contrast media. We will offer a perspective on the importance of chemical stability, particularly kinetic stability, and how this influences one's thinking about the safety of metal-ligand based contrast agents. We will discuss the mechanisms involved in magnetic resonance relaxation in the context of probe design strategies. A brief description of currently available contrast agents will be accompanied by an in-depth discussion that highlights promising MRI contrast agents in development for future clinical and research applications. Our intention is to give a diverse audience an improved understanding of the factors involved in developing new types of safe and highly efficient MR contrast agents and, at the same time, provide an appreciation of the insights into physiology and disease that newer types of responsive agents can provide. PMID:25975847

  2. Strategies for Optimizing Water-Exchange Rates of Lanthanide-Based Contrast Agents for Magnetic Resonance Imaging

    PubMed Central

    Siriwardena-Mahanama, Buddhima N.; Allen, Matthew J.

    2013-01-01

    This review describes recent advances in strategies for tuning the water-exchange rates of contrast agents for magnetic resonance imaging (MRI). Water-exchange rates play a critical role in determining the efficiency of contrast agents; consequently, optimization of water-exchange rates, among other parameters, is necessary to achieve high efficiencies. This need has resulted in extensive research efforts to modulate water-exchange rates by chemically altering the coordination environments of the metal complexes that function as contrast agents. The focus of this review is coordination-chemistry-based strategies used to tune the water-exchange rates of lanthanide(III)-based contrast agents for MRI. Emphasis will be given to results published in the 21st century, as well as implications of these strategies on the design of contrast agents. PMID:23921796

  3. Ultrasonic Analysis of Peptide- and Antibody-Targeted Microbubble Contrast Agents for Molecular Imaging of αvβ3-Expressing Cells

    PubMed Central

    Dayton, Paul A.; Pearson, David; Clark, Jarrod; Simon, Scott; Schumann, Patricia A.; Zutshi, Reena; Matsunaga, Terry O.; Ferrara, Katherine W.

    2008-01-01

    The goal of targeted ultrasound contrast agents is to significantly and selectively enhance the detection of a targeted vascular site. In this manuscript, three distinct contrast agents targeted to the αvβ3 integrin are examined. The αvβ3 integrin has been shown to be highly expressed on metastatic tumors and endothelial cells during neovascularization, and its expression has been shown to correlate with tumor grade. Specific adhesion of these contrast agents to αvβ3-expressing cell monolayers is demonstrated in vitro, and compared with that of nontargeted agents. Acoustic studies illustrate a backscatter amplitude increase from monolayers exposed to the targeted contrast agents of up to 13-fold (22 dB) relative to enhancement due to control bubbles. A linear dependence between the echo amplitude and bubble concentration was observed for bound agents. The decorrelation of the echo from adherent targeted agents is observed over successive pulses as a function of acoustic pressure and bubble density. Frequency–domain analysis demonstrates that adherent targeted bubbles exhibit high-amplitude narrowband echo components, in contrast to the primarily wideband response from free microbubbles. Results suggest that adherent targeted contrast agents are differentiable from free-floating microbubbles, that targeted contrast agents provide higher sensitivity in the detection of angiogenesis, and that conventional ultrasound imaging techniques such as signal subtraction or decorrelation detection can be used to detect integrin-expressing vasculature with sufficient signal-to-noise. PMID:15296677

  4. Contrast echocardiography: new agents.

    PubMed

    Miller, Andrew P; Nanda, Navin C

    2004-04-01

    In this report, we review the history, rationale, current status and future directions of contrast agents in echocardiography. First, we discuss the historic development of contrast agents through a review of important physical principles of microbubbles in ultrasonography. Second, we identify attributes of an ideal contrast agent and review those that are currently available or in the "pipeline" for clinical use. Third, we review indications for contrast echocardiography, including endocardial border detection, perfusion quantification and reperfusion assessment, and validate these observations by comparisons with other imaging modalities. Then, we briefly review different methodologies of performing a contrast study, including interrupted, real-time and a hybrid modality. Finally, we identify novel future applications of the newest contrast agents. These newer concepts in contrast echocardiography should form a foundation for nearly limitless application of echocardiography in improved anatomical assessment, perfusion imaging and even special applications, such as detection of vascular inflammation and site-specific drug delivery.

  5. Advancing pharmacovigilance through academic-legal collaboration: the case of gadolinium-based contrast agents and nephrogenic systemic fibrosis-a Research on Adverse Drug Events and Reports (RADAR) report.

    PubMed

    Edwards, B J; Laumann, A E; Nardone, B; Miller, F H; Restaino, J; Raisch, D W; McKoy, J M; Hammel, J A; Bhatt, K; Bauer, K; Samaras, A T; Fisher, M J; Bull, C; Saddleton, E; Belknap, S M; Thomsen, H S; Kanal, E; Cowper, S E; Abu Alfa, A K; West, D P

    2014-10-01

    To compare and contrast three databases, that is, The International Centre for Nephrogenic Systemic Fibrosis Registry (ICNSFR), the Food and Drug Administration Adverse Event Reporting System (FAERS) and a legal data set, through pharmacovigilance and to evaluate international nephrogenic systemic fibrosis (NSF) safety efforts. The Research on Adverse Drug events And Reports methodology was used for assessment-the FAERS (through June 2009), ICNSFR and the legal data set (January 2002 to December 2010). Safety information was obtained from the European Medicines Agency, the Danish Medicine Agency and the Food and Drug Administration. The FAERS encompassed the largest number (n = 1395) of NSF reports. The ICNSFR contained the most complete (n = 335, 100%) histopathological data. A total of 382 individual biopsy-proven, product-specific NSF cases were analysed from the legal data set. 76.2% (291/382) identified exposure to gadodiamide, of which 67.7% (197/291) were unconfounded. Additionally, 40.1% (153/382) of cases involved gadopentetate dimeglumine, of which 48.4% (74/153) were unconfounded, while gadoversetamide was identified in 7.3% (28/382) of which 28.6% (8/28) were unconfounded. Some cases involved gadobenate dimeglumine or gadoteridol, 5.8% (22/382), all of which were confounded. The mean number of exposures to gadolinium-based contrast agents (GBCAs) was gadodiamide (3), gadopentetate dimeglumine (5) and gadoversetamide (2). Of the 279 unconfounded cases, all involved a linear-structured GBCA. 205 (73.5%) were a non-ionic GBCA while 74 (26.5%) were an ionic GBCA. Clinical and legal databases exhibit unique characteristics that prove complementary in safety evaluations. Use of the legal data set allowed the identification of the most commonly implicated GBCA. This article is the first to demonstrate explicitly the utility of a legal data set to pharmacovigilance research.

  6. Application of gold nanoparticles as contrast agents in confocal laser scanning microscopy

    NASA Astrophysics Data System (ADS)

    Lemelle, A.; Veksler, B.; Kozhevnikov, I. S.; Akchurin, G. G.; Piletsky, S. A.; Meglinski, I.

    2009-01-01

    Confocal laser scanning microscopy (CLSM) is a modern high-resolution optical technique providing detailed image of tissue structure with high (down to microns) spatial resolution. Aiming at a concurrent improvement of imaging depth and image quality the CLSM requires the use of contrast agents. Commonly employed fluorescent contrast agents, such as fluorescent dyes and proteins, suffer from toxicity, photo-bleaching and overlapping with the tissues autofluorescence. Gold nanoparticles are potentially highly attractive to be applied as a contrast agent since they are not subject to photo-bleaching and can target biochemical cells markers associated with the specific diseases. In current report we consider the applicability of gold nano-spheres as a contrast agent to enhance quality of CLSM images of skin tissues in vitro versus the application of optical clearing agent, such as glycerol. The enhancement of CLSM image contrast was observed with an application of gold nano-spheres diffused within the skin tissues. We show that optical clearing agents such as a glycerol provide better CLSM image contrast than gold nano-spheres.

  7. Nitroxide-Based Macromolecular Contrast Agents with Unprecedented Transverse Relaxivity and Stability for Magnetic Resonance Imaging of Tumors

    PubMed Central

    2017-01-01

    Metal-free magnetic resonance imaging (MRI) agents could overcome the established toxicity associated with metal-based agents in some patient populations and enable new modes of functional MRI in vivo. Herein, we report nitroxide-functionalized brush-arm star polymer organic radical contrast agents (BASP-ORCAs) that overcome the low contrast and poor in vivo stability associated with nitroxide-based MRI contrast agents. As a consequence of their unique nanoarchitectures, BASP-ORCAs possess per-nitroxide transverse relaxivities up to ∼44-fold greater than common nitroxides, exceptional stability in highly reducing environments, and low toxicity. These features combine to provide for accumulation of a sufficient concentration of BASP-ORCA in murine subcutaneous tumors up to 20 h following systemic administration such that MRI contrast on par with metal-based agents is observed. BASP-ORCAs are, to our knowledge, the first nitroxide MRI contrast agents capable of tumor imaging over long time periods using clinical high-field 1H MRI techniques. PMID:28776023

  8. A targeted nanoglobular contrast agent from host-guest self-assembly for MR cancer molecular imaging

    PubMed Central

    Zhou, Zhuxian; Han, Zhen; Lu, Zheng-Rong

    2016-01-01

    The clinical application of nanoparticular Gd(III) based contrast agents for tumor molecular MRI has been hindered by safety concerns associated with prolonged tissue retention, although they can produce strong tumor enhancement. In this study, a targeted well-defined cyclodextrin-based nanoglobular contrast agent was developed through self-assembly driven by host-guest interactions for safe and effective cancer molecular MRI. Multiple β-cyclodextrins attached POSS (polyhedral oligomeric silsesquioxane) nanoglobule was used as host molecule. Adamantane–modified macrocyclic Gd(III) contrast agent, cRGD (cyclic RGDfK peptide) targeting ligand and fluorescent probe was used as guest molecules. The targeted host-guest nanoglobular contrast agent cRGD-POSS-βCD-(DOTA-Gd) specifically bond to αvβ3 integrin in malignant 4T1 breast tumor and provided greater contrast enhancement than the corresponding non-targeted agent. The agent also provided significant fluorescence signal in tumor tissue. The histological analysis of the tumor tissue confirmed its specific and effective targeting to αvβ3 integrin. The targeted imaging agent has a potential for specific cancer molecular MR and fluorescent imaging. PMID:26874280

  9. Submicron polycaprolactone particles as a carrier for imaging contrast agent for in vitro applications.

    PubMed

    Iqbal, Muhammad; Robin, Sophie; Humbert, Philippe; Viennet, Céline; Agusti, Geraldine; Fessi, Hatem; Elaissari, Abdelhamid

    2015-12-01

    Fluorescent materials have recently attracted considerable attention due to their unique properties and high performance as imaging agent in biomedical fields. Different imaging agents have been encapsulated in order to restrict its delivery to a specific area. In this study, a fluorescent contrast agent was encapsulated for in vitro application by polycaprolactone (PCL) polymer. The encapsulation was performed using modified double emulsion solvent evaporation technique with sonication. Fluorescent nanoparticles (20 nm) were incorporated in the inner aqueous phase of double emulsion. A number of samples were fabricated using different concentrations of fluorescent contrast agent. The contrast agent-containing submicron particle was characterized by a zetasizer for average particle size, SEM and TEM for morphology observations and fluorescence spectrophotometer for encapsulation efficiency. Moreover, contrast agent distribution in the PCL matrix was determined by confocal microscopy. The incorporation of contrast agent in different concentrations did not affect the physicochemical properties of PCL particles and the average size of encapsulated particles was found to be in the submicron range. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Polydisulfide Manganese(II) Complexes as Non-Gadolinium Biodegradable Macromolecular MRI Contrast Agents

    PubMed Central

    Ye, Zhen; Jeong, Eun-Kee; Wu, Xueming; Tan, Mingqian; Yin, Shouyu; Lu, Zheng-Rong

    2011-01-01

    Purpose To develop safe and effective manganese(II) based biodegradable macromolecular MRI contrast agents. Materials and Methods In this study, we synthesized and characterized two polydisulfide manganese(II) complexes, Mn-DTPA cystamine copolymers and Mn-EDTA cystamine copolymers, as new biodegradable macromolecular MRI contrast agents. The contrast enhancement of the two manganese based contrast agents were evaluated in mice bearing MDA-MB-231 human breast carcinoma xenografts, in comparison with MnCl2. Results The T1 and T2 relaxivities were 4.74 and 10.38 mM−1s−1 per manganese at 3T for Mn-DTPA cystamine copolymers (Mn=30.50 kDa) and 6.41 and 9.72 mM−1s−1 for Mn-EDTA cystamine copolymers (Mn= 61.80 kDa). Both polydisulfide Mn(II) complexes showed significant liver, myocardium and tumor enhancement. Conclusion The manganese based polydisulfide contrast agents have a potential to be developed as alternative non-gadolinium contrast agents for MR cancer and myocardium imaging. PMID:22031457

  11. The use of innovative gadolinium-based contrast agent for MR-diagnosis of cancer in the experiment

    NASA Astrophysics Data System (ADS)

    Chernov, V.; Medvedeva, A.; Sinilkin, I.; Zelchan, R.; Grigorev, E.; Frolova, I.; Nam, I.

    2016-02-01

    The present study of the functional suitability and specific activity of the contrast agent gadolinium-based for magnetic resonance imaging demonstrated that the investigated contrast agent intensively accumulates in organs and anatomical structures of the experimental animals. In the model of tumor lesions in animals, study have shown that investigational contrast agent accumulates in the tumor tissue and retained there in for a long enough time.

  12. Effects of iodinated contrast agent, xylocaine and gadolinium concentration on the signal emitted in magnetic resonance arthrography: a samples study*

    PubMed Central

    da Silva, Yvana Lopes Pinheiro; Costa, Rita Zanlorensi Visneck; Pinho, Kátia Elisa Prus; Ferreira, Ricardo Rabello; Schuindt, Sueliton Miyamoto

    2015-01-01

    Objective To investigate the effects of dilution of paramagnetic contrast agent with iodinated contrast and xylocaine on the signal intensity during magnetic resonance arthrography, and to improve the paramagnetic contrast agent concentration utilized in this imaging modality. Materials and Methods Samples specially prepared for the study with three different concentrations of paramagnetic contrast agent diluted in saline, iodinated contrast agent and xylocaine were imaged with fast spin echo T1-weighted sequences with fat saturation. The samples were placed into flasks and graphical analysis of the signal intensity was performed as a function of the paramagnetic contrast concentration. Results As compared with samples of equal concentrations diluted only with saline, the authors have observed an average signal intensity decrease of 20.67% for iodinated contrast agent, and of 28.34% for xylocaine. However, the increased gadolinium concentration in the samples caused decrease in signal intensity with all the dilutions. Conclusion Minimizing the use of iodinated contrast media and xylocaine and/or the use of a gadolinium concentration of 2.5 mmol/L diluted in saline will improve the sensitivity of magnetic resonance arthrography. PMID:25987746

  13. CHANGES IN LIPID-ENCAPSULATED MICROBUBBLE POPULATION DURING CONTINUOUS INFUSION AND METHODS TO MAINTAIN CONSISTENCY

    PubMed Central

    KAYA, MEHMET; GREGORY, THOMAS S.; DAYTON, PAUL A.

    2009-01-01

    Stabilized microbubbles are utilized as ultrasound contrast agents. These micron-sized gas capsules are injected into the bloodstream to provide contrast enhancement during ultrasound imaging. Some contrast imaging strategies, such as destruction-reperfusion, require a continuous injection of microbubbles over several minutes. Most quantitative imaging strategies rely on the ability to administer a consistent dose of contrast agent. Because of the buoyancy of these gas-filled agents, their spatial distribution within a syringe changes over time. The population of microbubbles that is pumped from a horizontal syringe outlet differs from initial population as the microbubbles float to the syringe top. In this manuscript, we study the changes in the population of a contrast agent that is pumped from a syringe due to microbubble floatation. Results are presented in terms of change in concentration and change in mean diameter, as a function of time, suspension medium, and syringe diameter. Data illustrate that the distribution of contrast agents injected from a syringe changes in both concentration and mean diameter over several minutes without mixing. We discuss the application of a mixing system and viscosity agents to keep the contrast solution more evenly distributed in a syringe. These results are significant for researchers utilizing microbubble contrast agents in continuous-infusion applications where it is important to maintain consistent contrast agent delivery rate, or in situations where the injection syringe cannot be mixed immediately prior to administration. PMID:19632760

  14. Contrast agent enhanced pQCT of articular cartilage

    NASA Astrophysics Data System (ADS)

    Kallioniemi, A. S.; Jurvelin, J. S.; Nieminen, M. T.; Lammi, M. J.; Töyräs, J.

    2007-02-01

    The delayed gadolinium enhanced MRI of cartilage (dGEMRIC) technique is the only non-invasive means to estimate proteoglycan (PG) content in articular cartilage. In dGEMRIC, the anionic paramagnetic contrast agent gadopentetate distributes in inverse relation to negatively charged PGs, leading to a linear relation between T1,Gd and spatial PG content in tissue. In the present study, for the first time, contrast agent enhanced peripheral quantitative computed tomography (pQCT) was applied, analogously to dGEMRIC, for the quantitative detection of spatial PG content in cartilage. The suitability of two anionic radiographic contrast agents, gadopentetate and ioxaglate, to detect enzymatically induced PG depletion in articular cartilage was investigated. First, the interrelationships of x-ray absorption, as measured with pQCT, and the contrast agent solution concentration were investigated. Optimal contrast agent concentrations for the following experiments were selected. Second, diffusion rates for both contrast agents were investigated in intact (n = 3) and trypsin-degraded (n = 3) bovine patellar cartilage. The contrast agent concentration of the cartilaginous layer was measured prior to and 2-27 h after immersion. Optimal immersion time for the further experiments was selected. Third, the suitability of gadopentetate and ioxaglate enhanced pQCT to detect the enzymatically induced specific PG depletion was investigated by determining the contrast agent concentrations and uronic acid and water contents in digested and intact osteochondral samples (n = 16). After trypsin-induced PG loss (-70%, p < 0.05) the penetration of gadopentetate and ioxaglate increased (p < 0.05) by 34% and 48%, respectively. Gadopentetate and ioxaglate concentrations both showed strong correlation (r = -0.95, r = -0.94, p < 0.01, respectively) with the uronic acid content. To conclude, contrast agent enhanced pQCT provides a technique to quantify PG content in normal and experimentally degraded articular cartilage in vitro. As high resolution imaging of e.g. the knee joint is possible with pQCT, the present technique may be further developed for in vivo quantification of PG depletion in osteoarthritic cartilage. However, careful in vitro and in vivo characterization of diffusion mechanics and optimal contrast agent concentrations are needed before diagnostic applications are feasible.

  15. Biological agents database in the armed forces.

    PubMed

    Niemcewicz, Marcin; Kocik, Janusz; Bielecka, Anna; Wierciński, Michał

    2014-10-01

    Rapid detection and identification of the biological agent during both, natural or deliberate outbreak is crucial for implementation of appropriate control measures and procedures in order to mitigate the spread of disease. Determination of pathogen etiology may not only support epidemiological investigation and safety of human beings, but also enhance forensic efforts in pathogen tracing, collection of evidences and correct inference. The article presents objectives of the Biological Agents Database, which was developed for the purpose of the Ministry of National Defense of the Republic of Poland under the European Defence Agency frame. The Biological Agents Database is an electronic catalogue of genetic markers of highly dangerous pathogens and biological agents of weapon of mass destruction concern, which provides full identification of biological threats emerging in Poland and in locations of activity of Polish troops. The Biological Agents Database is a supportive tool used for tracing biological agents' origin as well as rapid identification of agent causing the disease of unknown etiology. It also provides support in diagnosis, analysis, response and exchange of information between institutions that use information contained in it. Therefore, it can be used not only for military purposes, but also in a civilian environment.

  16. Safe Use of Contrast Media: What the Radiologist Needs to Know.

    PubMed

    Beckett, Katrina R; Moriarity, Andrew K; Langer, Jessica M

    2015-10-01

    Iodinated and gadolinium-based contrast media are used on a daily basis in most radiology practices. These agents often are essential to providing accurate diagnoses, and are nearly always safe and effective when administered correctly. However, reactions to contrast media do occur and can be life threatening. Therefore, it is critical for faculty and staff to know how reactions to contrast agents manifest and how to treat them promptly. The decline in renal function seen occasionally after intravenous administration of iodinated contrast agents is poorly understood and likely multifactorial, and its association with the contrast medium may be overemphasized. However, it is important that radiologists be aware of current understanding and strategies to decrease the incidence of renal dysfunction. Nephrogenic systemic fibrosis, a skin disease, is an adverse reaction related to use of some gadolinium-based contrast agents in patients with chronic renal failure. The types of gadolinium most often associated with this condition and the indications for withholding gadolinium are important and are discussed in this article. The use of enteric contrast agents and contrast agents during pregnancy and nursing are reviewed briefly. Current knowledge for safe use of contrast media and key concepts that all radiologists should know are summarized in this review. © RSNA, 2015.

  17. Development of contrast agents targeted to macrophage scavenger receptors for MRI of vascular inflammation

    PubMed Central

    Gustafsson, Björn; Youens, Susan; Louie, Angelique Y.

    2008-01-01

    Atherosclerosis is a leading cause of death in the U.S. Because there is a potential to prevent coronary and arterial diseases through early diagnosis, there is a need for methods to image arteries in the sub-clinical stage as well as clinical stage using various non-invasive techniques, including Magnetic Resonance Imaging (MRI). We describe a development of a novel MRI contrast agent targeted to plaques that will allow imaging of lesion formation. The contrast agent is directed to macrophages, one of the earliest components of developing plaques. Macrophages are labeled through the macrophage scavenger receptor A, a macrophage specific cell surface protein, using an MRI contrast agent derived from scavenger receptor ligands. We have synthesized and characterized these contrast agents with a range of relaxivities. In vitro studies show that the targeted contrast agent accumulates in macrophages and solution studies indicate that micromolar concentrations are sufficient to produce contrast in an MR image. Cell toxicity and initial biodistribution studies indicate low toxicity, no detectable retention in normal blood vessels, and rapid clearance from blood. The promising performance of this contrast agent targeted towards vascular inflammation opens doors to tracking of other inflammatory diseases such as tumor immunotherapy and transplant acceptance using MRI. PMID:16536488

  18. Contrast-enhanced peripheral MRA: technique and contrast agents.

    PubMed

    Nielsen, Yousef W; Thomsen, Henrik S

    2012-09-01

    In the last decade contrast-enhanced magnetic resonance angiography (CE-MRA) has gained wide acceptance as a valuable tool in the diagnostic work-up of patients with peripheral arterial disease. This review presents current concepts in peripheral CE-MRA with emphasis on MRI technique and contrast agents. Peripheral CE-MRA is defined as an MR angiogram of the arteries from the aortic bifurcation to the feet. Advantages of CE-MRA include minimal invasiveness and lack of ionizing radiation. The basic technique employed for peripheral CE-MRA is the bolus-chase method. With this method a paramagnetic MRI contrast agent is injected intravenously and T1-weighted images are acquired in the subsequent arterial first-pass phase. In order to achieve high quality MR angiograms without interfering venous contamination or artifacts, a number of factors need to be taken into account. This includes magnetic field strength of the MRI system, receiver coil configuration, use of parallel imaging, contrast bolus timing technique, and k-space filling strategies. Furthermore, it is possible to optimize peripheral CE-MRA using venous compression techniques, hybrid scan protocols, time-resolved imaging, and steady-state MRA. Gadolinium(Gd)-based contrast agents are used for CE-MRA of the peripheral arteries. Extracellular Gd agents have a pharmacokinetic profile similar to iodinated contrast media. Accordingly, these agents are employed for first-pass MRA. Blood-pool Gd-based agents are characterized by prolonged intravascular stay, due to macromolecular structure or protein binding. These agents can be used for first-pass, as well as steady-state MRA. Some Gd-based contrast agents with low thermodynamic stability have been linked to development of nephrogenic systemic fibrosis in patients with severe renal insufficiency. Using optimized technique and a stable MRI contrast agent, peripheral CE-MRA is a safe procedure with diagnostic accuracy close to that of conventional catheter X-ray angiography.

  19. Double agents and secret agents: the emerging fields of exogenous chemical exchange saturation transfer and T2-exchange magnetic resonance imaging contrast agents for molecular imaging.

    PubMed

    Daryaei, Iman; Pagel, Mark D

    2015-01-01

    Two relatively new types of exogenous magnetic resonance imaging contrast agents may provide greater impact for molecular imaging by providing greater specificity for detecting molecular imaging biomarkers. Exogenous chemical exchange saturation transfer (CEST) agents rely on the selective saturation of the magnetization of a proton on an agent, followed by chemical exchange of a proton from the agent to water. The selective detection of a biomarker-responsive CEST signal and an unresponsive CEST signal, followed by the ratiometric comparison of these signals, can improve biomarker specificity. We refer to this improvement as a "double-agent" approach to molecular imaging. Exogenous T 2 -exchange agents also rely on chemical exchange of protons between the agent and water, especially with an intermediate rate that lies between the slow exchange rates of CEST agents and the fast exchange rates of traditional T 1 and T 2 agents. Because of this intermediate exchange rate, these agents have been relatively unknown and have acted as "secret agents" in the contrast agent research field. This review exposes these secret agents and describes the merits of double agents through examples of exogenous agents that detect enzyme activity, nucleic acids and gene expression, metabolites, ions, redox state, temperature, and pH. Future directions are also provided for improving both types of contrast agents for improved molecular imaging and clinical translation. Therefore, this review provides an overview of two new types of exogenous contrast agents that are becoming useful tools within the armamentarium of molecular imaging.

  20. Nuclear magnetic resonance contrast agents

    DOEpatents

    Smith, P.H.; Brainard, J.R.; Jarvinen, G.D.; Ryan, R.R.

    1997-12-30

    A family of contrast agents for use in magnetic resonance imaging and a method of enhancing the contrast of magnetic resonance images of an object by incorporating a contrast agent of this invention into the object prior to forming the images or during formation of the images. A contrast agent of this invention is a paramagnetic lanthanide hexaazamacrocyclic molecule, where a basic example has the formula LnC{sub 16}H{sub 14}N{sub 6}. Important applications of the invention are in medical diagnosis, treatment, and research, where images of portions of a human body are formed by means of magnetic resonance techniques. 10 figs.

  1. Nuclear magnetic resonance contrast agents

    DOEpatents

    Smith, Paul H.; Brainard, James R.; Jarvinen, Gordon D.; Ryan, Robert R.

    1997-01-01

    A family of contrast agents for use in magnetic resonance imaging and a method of enhancing the contrast of magnetic resonance images of an object by incorporating a contrast agent of this invention into the object prior to forming the images or during formation of the images. A contrast agent of this invention is a paramagnetic lanthanide hexaazamacrocyclic molecule, where a basic example has the formula LnC.sub.16 H.sub.14 N.sub.6. Important applications of the invention are in medical diagnosis, treatment, and research, where images of portions of a human body are formed by means of magnetic resonance techniques.

  2. Comparison of contrast media for visualization of the colon of healthy dogs during computed tomography and ultrasonography.

    PubMed

    Cheon, Byunggyu; Moon, Sohyeon; Park, Seungjo; Lee, Sang-Kwon; Hong, Sunghwa; Cho, Hyun; Choi, Jihye

    2016-11-01

    OBJECTIVE To evaluate contrast agents for their ability to improve visualization of the colon wall and lumen during CT and ultrasonography. ANIMALS 10 healthy adult Beagles. PROCEDURES Food was withheld from dogs for 36 hours, after which dogs consumed 250 mL of polyethylene glycol solution. Dogs were then anesthetized, a contrast agent (tap water, diluted barium, or air; order randomly assigned) was administered rectally, iodine contrast medium (880 mg of I/kg) was administered IV, and CT and ultrasonography of the colon were performed. After a 1-week washout period, this process was repeated with a different contrast agent until all agents had been evaluated. Two investigators reviewed the CT and ultrasonographic images for colon wall thickness, conspicuity, artifacts, wall layering, and degree of lumen dilation at 4 sites. RESULTS Thickness of the colon wall was greatest in CT and ultrasonographic images with water used as contrast agent, followed by barium and then air. The CT images obtained after water administration had a smooth appearance that outlined the colonic mucosa and had the highest score of the 3 contrast agents for wall conspicuity. Although no substantial artifacts related to any of the contrast agents were identified on CT images, barium- and gas-induced shadowing and reverberation artifacts hindered wall evaluation during ultrasonography. For ultrasonography, the degree of conspicuity was highest with barium in the near-field wall and with water in the far-field wall. In contrast to CT, ultrasonography could be used to distinguish wall layering, and the mucosal and muscular layers were distinct with all contrast agents. CONCLUSIONS AND CLINICAL RELEVANCE Use of water as a contrast agent for both CT and ultrasonography of the colon in dogs compensated for each imaging modality's disadvantages and could be beneficial in the diagnosis of colon disease.

  3. A targeted nanoglobular contrast agent from host-guest self-assembly for MR cancer molecular imaging.

    PubMed

    Zhou, Zhuxian; Han, Zhen; Lu, Zheng-Rong

    2016-04-01

    The clinical application of nanoparticular Gd(III) based contrast agents for tumor molecular MRI has been hindered by safety concerns associated with prolonged tissue retention, although they can produce strong tumor enhancement. In this study, a targeted well-defined cyclodextrin-based nanoglobular contrast agent was developed through self-assembly driven by host-guest interactions for safe and effective cancer molecular MRI. Multiple β-cyclodextrins attached POSS (polyhedral oligomeric silsesquioxane) nanoglobule was used as host molecule. Adamantane-modified macrocyclic Gd(III) contrast agent, cRGD (cyclic RGDfK peptide) targeting ligand and fluorescent probe was used as guest molecules. The targeted host-guest nanoglobular contrast agent cRGD-POSS-βCD-(DOTA-Gd) specifically bond to αvβ3 integrin in malignant 4T1 breast tumor and provided greater contrast enhancement than the corresponding non-targeted agent. The agent also provided significant fluorescence signal in tumor tissue. The histological analysis of the tumor tissue confirmed its specific and effective targeting to αvβ3 integrin. The targeted imaging agent has a potential for specific cancer molecular MR and fluorescent imaging. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Contrast agents in dynamic contrast-enhanced magnetic resonance imaging

    PubMed Central

    Yan, Yuling; Sun, Xilin; Shen, Baozhong

    2017-01-01

    Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is a noninvasive method to assess angiogenesis, which is widely used in clinical applications including diagnosis, monitoring therapy response and prognosis estimation in cancer patients. Contrast agents play a crucial role in DCE-MRI and should be carefully selected in order to improve accuracy in DCE-MRI examination. Over the past decades, there was much progress in the development of optimal contrast agents in DCE-MRI. In this review, we describe the recent research advances in this field and discuss properties of contrast agents, as well as their advantages and disadvantages. Finally, we discuss the research perspectives for improving this promising imaging method. PMID:28415647

  5. The evolution of gadolinium based contrast agents: from single-modality to multi-modality

    NASA Astrophysics Data System (ADS)

    Zhang, Li; Liu, Ruiqing; Peng, Hui; Li, Penghui; Xu, Zushun; Whittaker, Andrew K.

    2016-05-01

    Gadolinium-based contrast agents are extensively used as magnetic resonance imaging (MRI) contrast agents due to their outstanding signal enhancement and ease of chemical modification. However, it is increasingly recognized that information obtained from single modal molecular imaging cannot satisfy the higher requirements on the efficiency and accuracy for clinical diagnosis and medical research, due to its limitation and default rooted in single molecular imaging technique itself. To compensate for the deficiencies of single function magnetic resonance imaging contrast agents, the combination of multi-modality imaging has turned to be the research hotpot in recent years. This review presents an overview on the recent developments of the functionalization of gadolinium-based contrast agents, and their application in biomedicine applications.

  6. Imaging-related medications: a class overview

    PubMed Central

    2007-01-01

    Imaging-related medications (contrast agents) are commonly utilized to improve visualization of radiographic, computed tomography (CT), and magnetic resonance (MR) images. While traditional medications are used specifically for their pharmacological actions, the ideal imaging agent provides enhanced contrast with little biological interaction. The radiopaque agents, barium sulfate and iodinated contrast agents, confer “contrast” to x-ray films by their physical ability to directly absorb x-rays. Gadolinium-based MR agents enhance visualization of tissues when exposed to a magnetic field. Ferrous-ferric oxide–based paramagnetic agents provide negative contrast for MR liver studies. This article provides an overview of clinically relevant information for the imaging-related medications commonly in use. It reviews the safety improvements in new generations of drugs; risk factors and precautions for the reduction of severe adverse reactions (i.e., extravasation, contrast-induced nephropathy, metformin-induced lactic acidosis, and nephrogenic fibrosing dermopathy/nephrogenic systemic fibrosis); and the significance of diligent patient screening before contrast exposure and appropriate monitoring after exposure. PMID:17948119

  7. A Pictorial Review of Hepatobiliary Magnetic Resonance Imaging With Hepatocyte-Specific Contrast Agents: Uses, Findings, and Pitfalls of Gadoxetate Disodium and Gadobenate Dimeglumine.

    PubMed

    Scali, Elena P; Walshe, Triona; Tiwari, Hina Arif; Harris, Alison C; Chang, Silvia D

    2017-08-01

    Magnetic resonance imaging (MRI) has a well-established role as a highly specific and accurate modality for characterizing benign and malignant focal liver lesions. In particular, contrast-enhanced MRI using hepatocyte-specific contrast agents (HSCAs) improves lesion detection and characterization compared to other imaging modalities and MRI techniques. In this pictorial review, the mechanism of action of gadolinium-based MRI contrast agents, with a focus on HSCAs, is described. The clinical indications, protocols, and emerging uses of the 2 commercially available combined contrast agents available in the United States, gadoxetate disodium and gadobenate dimeglumine, are discussed. The MRI features of these agents are compared with examples of focal hepatic masses, many of which have been obtained within the same patient therefore allowing direct lesion comparison. Finally, the pitfalls in the use of combined contrast agents in liver MRI are highlighted. Copyright © 2016 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  8. Double agents and secret agents: the emerging fields of exogenous chemical exchange saturation transfer and T2-exchange magnetic resonance imaging contrast agents for molecular imaging

    PubMed Central

    Daryaei, Iman; Pagel, Mark D

    2016-01-01

    Two relatively new types of exogenous magnetic resonance imaging contrast agents may provide greater impact for molecular imaging by providing greater specificity for detecting molecular imaging biomarkers. Exogenous chemical exchange saturation transfer (CEST) agents rely on the selective saturation of the magnetization of a proton on an agent, followed by chemical exchange of a proton from the agent to water. The selective detection of a biomarker-responsive CEST signal and an unresponsive CEST signal, followed by the ratiometric comparison of these signals, can improve biomarker specificity. We refer to this improvement as a “double-agent” approach to molecular imaging. Exogenous T2-exchange agents also rely on chemical exchange of protons between the agent and water, especially with an intermediate rate that lies between the slow exchange rates of CEST agents and the fast exchange rates of traditional T1 and T2 agents. Because of this intermediate exchange rate, these agents have been relatively unknown and have acted as “secret agents” in the contrast agent research field. This review exposes these secret agents and describes the merits of double agents through examples of exogenous agents that detect enzyme activity, nucleic acids and gene expression, metabolites, ions, redox state, temperature, and pH. Future directions are also provided for improving both types of contrast agents for improved molecular imaging and clinical translation. Therefore, this review provides an overview of two new types of exogenous contrast agents that are becoming useful tools within the armamentarium of molecular imaging. PMID:27747191

  9. Nanoparticles in magnetic resonance imaging: from simple to dual contrast agents

    PubMed Central

    Estelrich, Joan; Sánchez-Martín, María Jesús; Busquets, Maria Antònia

    2015-01-01

    Magnetic resonance imaging (MRI) has become one of the most widely used and powerful tools for noninvasive clinical diagnosis owing to its high degree of soft tissue contrast, spatial resolution, and depth of penetration. MRI signal intensity is related to the relaxation times (T1, spin–lattice relaxation and T2, spin–spin relaxation) of in vivo water protons. To increase contrast, various inorganic nanoparticles and complexes (the so-called contrast agents) are administered prior to the scanning. Shortening T1 and T2 increases the corresponding relaxation rates, 1/T1 and 1/T2, producing hyperintense and hypointense signals respectively in shorter times. Moreover, the signal-to-noise ratio can be improved with the acquisition of a large number of measurements. The contrast agents used are generally based on either iron oxide nanoparticles or ferrites, providing negative contrast in T2-weighted images; or complexes of lanthanide metals (mostly containing gadolinium ions), providing positive contrast in T1-weighted images. Recently, lanthanide complexes have been immobilized in nanostructured materials in order to develop a new class of contrast agents with functions including blood-pool and organ (or tumor) targeting. Meanwhile, to overcome the limitations of individual imaging modalities, multimodal imaging techniques have been developed. An important challenge is to design all-in-one contrast agents that can be detected by multimodal techniques. Magnetoliposomes are efficient multimodal contrast agents. They can simultaneously bear both kinds of contrast and can, furthermore, incorporate targeting ligands and chains of polyethylene glycol to enhance the accumulation of nanoparticles at the site of interest and the bioavailability, respectively. Here, we review the most important characteristics of the nanoparticles or complexes used as MRI contrast agents. PMID:25834422

  10. Dual Contrast CT Method Enables Diagnostics of Cartilage Injuries and Degeneration Using a Single CT Image.

    PubMed

    Saukko, Annina E A; Honkanen, Juuso T J; Xu, Wujun; Väänänen, Sami P; Jurvelin, Jukka S; Lehto, Vesa-Pekka; Töyräs, Juha

    2017-12-01

    Cartilage injuries may be detected using contrast-enhanced computed tomography (CECT) by observing variations in distribution of anionic contrast agent within cartilage. Currently, clinical CECT enables detection of injuries and related post-traumatic degeneration based on two subsequent CT scans. The first scan allows segmentation of articular surfaces and lesions while the latter scan allows evaluation of tissue properties. Segmentation of articular surfaces from the latter scan is difficult since the contrast agent diffusion diminishes the image contrast at surfaces. We hypothesize that this can be overcome by mixing anionic contrast agent (ioxaglate) with bismuth oxide nanoparticles (BINPs) too large to diffuse into cartilage, inducing a high contrast at the surfaces. Here, a dual contrast method employing this mixture is evaluated by determining the depth-wise X-ray attenuation profiles in intact, enzymatically degraded, and mechanically injured osteochondral samples (n = 3 × 10) using a microCT immediately and at 45 min after immersion in contrast agent. BiNPs were unable to diffuse into cartilage, producing high contrast at articular surfaces. Ioxaglate enabled the detection of enzymatic and mechanical degeneration. In conclusion, the dual contrast method allowed detection of injuries and degeneration simultaneously with accurate cartilage segmentation using a single scan conducted at 45 min after contrast agent administration.

  11. Active extravasation of gadolinium-based contrast agent into the subdural space following lumbar puncture.

    PubMed

    Kothari, Pranay D; Hanser, Evelyn M; Wang, Harrison; Farid, Nikdokht

    2016-01-01

    A 38year-old male presented with cauda equina syndrome following multiple lumbar puncture attempts. Lumbar spine magnetic resonance imaging (MRI) showed a subdural hematoma and an area of apparent contrast enhancement in the spinal canal on sagittal post-contrast images. Axial post-contrast images obtained seven minutes later demonstrated an increase in size and change in shape of the region of apparent contrast enhancement, indicating active extravasation of the contrast agent. This is the first reported case of active extravasation of gadolinium-based contrast agent in the spine. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. X-ray spatial frequency heterodyne imaging of protein-based nanobubble contrast agents

    PubMed Central

    Rand, Danielle; Uchida, Masaki; Douglas, Trevor; Rose-Petruck, Christoph

    2014-01-01

    Spatial Frequency Heterodyne Imaging (SFHI) is a novel x-ray scatter imaging technique that utilizes nanoparticle contrast agents. The enhanced sensitivity of this new technique relative to traditional absorption-based x-ray radiography makes it promising for applications in biomedical and materials imaging. Although previous studies on SFHI have utilized only metal nanoparticle contrast agents, we show that nanomaterials with a much lower electron density are also suitable. We prepared protein-based “nanobubble” contrast agents that are comprised of protein cage architectures filled with gas. Results show that these nanobubbles provide contrast in SFHI comparable to that of gold nanoparticles of similar size. PMID:25321797

  13. Exogenous contrast agents for thermoacoustic imaging: An investigation into the underlying sources of contrast

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ogunlade, Olumide, E-mail: o.ogunlade@ucl.ac.uk; Beard, Paul

    2015-01-15

    Purpose: Thermoacoustic imaging at microwave excitation frequencies is limited by the low differential contrast exhibited by high water content tissues. To overcome this, exogenous thermoacoustic contrast agents based on gadolinium compounds, iron oxide, and single wall carbon nanotubes have previously been suggested and investigated. However, these previous studies did not fully characterize the electric, magnetic, and thermodynamic properties of these agents thus precluding identification of the underlying sources of contrast. To address this, measurements of the complex permittivity, complex permeability, DC conductivity, and Grüneisen parameter have been made. These measurements allowed the origins of the contrast provided by each substancemore » to be identified. Methods: The electric and magnetic properties of the contrast agents were characterized at 3 GHz using two rectangular waveguide cavities. The DC conductivity was measured separately using a conductivity meter. Thermoacoustic signals were then acquired and compared to those generated in water. Finally, 3D electromagnetic simulations were used to decouple the different contributions to the absorbed power density. Results: It was found that the gadolinium compounds provided appreciable electric contrast but not originating from the gadolinium itself. The contrast was either due to dissociation of the gadolinium salt which increased ionic conductivity or its nondissociated polar fraction which increased dielectric polarization loss or a combination of both. In addition, very high concentrations were required to achieve appreciable contrast, to the extent that the Grüneisen parameter increased significantly and became a source of contrast. Iron oxide particles were found to produce low but measurable dielectric contrast due to dielectric polarization loss, but this is attributed to the coating of the particles not the iron oxide. Single wall carbon nanotubes did not provide measurable contrast of any type. Conclusions: It is concluded that gadolinium based contrast agents, iron oxide particles, and single walled carbon nanotubes have little intrinsic merit as thermoacoustic contrast agents. Simple electrolytes such as saline which yield high contrast based on ionic conductivity provide much higher dielectric contrast per unit solute concentration and are likely to be significantly more effective as contrast agents.« less

  14. Solute Transport of Negatively Charged Contrast Agents Across Articular Surface of Injured Cartilage.

    PubMed

    Kokkonen, H T; Chin, H C; Töyräs, J; Jurvelin, J S; Quinn, T M

    2017-04-01

    Solute transport through the extracellular matrix (ECM) is crucial to chondrocyte metabolism. Cartilage injury affects solute transport in cartilage due to alterations in ECM structure and solute-matrix interactions. Therefore, cartilage injury may be detected by using contrast agent-based clinical imaging. In the present study, effects of mechanical injury on transport of negatively charged contrast agents in cartilage were characterized. Using cartilage plugs injured by mechanical compression protocol, effective partition coefficients and diffusion fluxes of iodine- and gadolinium-based contrast agents were measured using high resolution microCT imaging. For all contrast agents studied, effective diffusion fluxes increased significantly, particularly at early times during the diffusion process (38 and 33% increase after 4 min, P < 0.05 for iodine and Gd-DTPA; and 76% increase after 10 min for diatrizoate, P < 0.05). Effective partition coefficients were unaffected in mechanically injured cartilage. Mechanical injury reduced PG content and collagen integrity in cartilage superficial zone. This study suggests that alterations in contrast agent diffusion flux, a non-equilibrium transport parameter, provides a more sensitive indicator for assessment of cartilage matrix integrity than partition coefficient and the equilibrium distribution of solute. These findings may help in developing clinical methods of contrast agent-based imaging to detect cartilage injury.

  15. Pediatric Patients Demonstrate Progressive T1-Weighted Hyperintensity in the Dentate Nucleus following Multiple Doses of Gadolinium-Based Contrast Agent.

    PubMed

    Roberts, D R; Chatterjee, A R; Yazdani, M; Marebwa, B; Brown, T; Collins, H; Bolles, G; Jenrette, J M; Nietert, P J; Zhu, X

    2016-12-01

    While there have been recent reports of brain retention of gadolinium following gadolinium-based contrast agent administration in adults, a retrospective series of pediatric patients has not previously been reported, to our knowledge. We investigated the relationship between the number of prior gadolinium-based contrast agent doses and increasing T1 signal in the dentate nucleus on unenhanced T1-weighted MR imaging. We hypothesized that despite differences in pediatric physiology and the smaller gadolinium-based contrast agent doses that pediatric patients are typically administered based on weighted-adjusted dosing, the pediatric brain would also demonstrate dose-dependent increasing T1 signal in the dentate nucleus. We included children with multiple gadolinium-based contrast agent administrations at our institution. A blinded reader placed ROIs within the dentate nucleus and adjacent cerebellar white matter. To eliminate reader bias, we also performed automated ROI delineation of the dentate nucleus, cerebellar white matter, and pons. Dentate-to-cerebellar white matter and dentate-to pons ratios were compared with the number of gadolinium-based contrast agent administrations. During 20 years at our institution, 280 patients received at least 5 gadolinium-based contrast agent doses, with 1 patient receiving 38 doses. Sixteen patients met the inclusion/exclusion criteria for ROI analysis. Blinded reader dentate-to-cerebellar white matter ratios were significantly associated with gadolinium-based contrast agent doses (r s = 0.77, P = .001). The dentate-to-pons ratio and dentate-to-cerebellar white matter ratios based on automated ROI placement were also significantly correlated with gadolinium-based contrast agent doses (t = 4.98, P < .0001 and t = 2.73, P < .02, respectively). In pediatric patients, the number of prior gadolinium-based contrast agent doses is significantly correlated with progressive T1-weighted dentate hyperintensity. Definitive confirmation of gadolinium deposition requires tissue analysis. Any potential clinical sequelae of gadolinium retention in the developing brain are unknown. Given this uncertainty, we suggest taking a cautious stance, including the use, in pediatric patients, of higher stability, macrocyclic agents, which in both human and animal studies have been shown to be associated with lower levels of gadolinium deposition, and detailed documentation of dosing. Most important, a patient should not be deprived of a well-indicated contrasted MR examination. © 2016 by American Journal of Neuroradiology.

  16. Molecular Contrast Optical Coherence Tomography: A Review¶

    PubMed Central

    Yang, Changhuei

    2005-01-01

    This article reviews the current state of research on the use of molecular contrast agents in optical coherence tomography (OCT) imaging techniques. After a brief discussion of the basic principle of OCT and the importance of incorporating molecular contrast agent usage into this imaging modality, we shall present an overview of the different molecular contrast OCT (MCOCT) methods that have been developed thus far. We will then discuss several important practical issues that define the possible range of contrast agent choice, the design criteria for engineered molecular contrast agent and the implementability of a given MCOCT method for clinical or biological applications. We will conclude by outlining a few areas of pursuit that deserve a greater degree of research and development. PMID:15588122

  17. Technical aspects of contrast-enhanced ultrasound (CEUS) examinations: tips and tricks.

    PubMed

    Greis, C

    2014-01-01

    Ultrasound contrast agents have substantially extended the clinical value of ultrasound, allowing the assessment of blood flow and distribution in real-time down to microcapillary level. Selective imaging of contrast agent signals requires a contrast-specific imaging mode on the ultrasound scanner, allowing real-time separation of tissue and contrast agent signals. The creation of a contrast image requires a specific interaction between the insonated ultrasound wave and the contrast agent microbubbles, leading to persistent oscillation of the bubbles. Several technical and procedural parameters have a significant influence on the quality of CEUS images and should be controlled carefully to obtain good image quality and a reliable diagnosis. Achieving the proper balance between the respective parameters is a matter of technical knowledge and experience. Appropriate training and education should be mandatory for every investigator performing CEUS examinations.

  18. Pre-clinical evaluation of a nanoparticle-based blood-pool contrast agent for MR imaging of the placenta.

    PubMed

    Ghaghada, Ketan B; Starosolski, Zbigniew A; Bhayana, Saakshi; Stupin, Igor; Patel, Chandreshkumar V; Bhavane, Rohan C; Gao, Haijun; Bednov, Andrey; Yallampalli, Chandrasekhar; Belfort, Michael; George, Verghese; Annapragada, Ananth V

    2017-09-01

    Non-invasive 3D imaging that enables clear visualization of placental margins is of interest in the accurate diagnosis of placental pathologies. This study investigated if contrast-enhanced MRI performed using a liposomal gadolinium blood-pool contrast agent (liposomal-Gd) enables clear visualization of the placental margins and the placental-myometrial interface (retroplacental space). Non-contrast MRI and contrast-enhanced MRI using a clinically approved conventional contrast agent were used as comparators. Studies were performed in pregnant rats under an approved protocol. MRI was performed at 1T using a permanent magnet small animal scanner. Pre-contrast and post-liposomal-Gd contrast images were acquired using T1-weighted and T2-weighted sequences. Dynamic Contrast enhanced MRI (DCE-MRI) was performed using gadoterate meglumine (Gd-DOTA, Dotarem ® ). Visualization of the retroplacental clear space, a marker of normal placentation, was judged by a trained radiologist. Signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were calculated for both single and averaged acquisitions. Images were reviewed by a radiologist and scored for the visualization of placental features. Contrast-enhanced CT (CE-CT) imaging using a liposomal CT agent was performed for confirmation of the MR findings. Transplacental transport of liposomal-Gd was evaluated by post-mortem elemental analysis of tissues. Ex-vivo studies in perfused human placentae from normal, GDM, and IUGR pregnancies evaluated the transport of liposomal agent across the human placental barrier. Post-contrast T1w images acquired with liposomal-Gd demonstrated significantly higher SNR (p = 0.0002) in the placenta compared to pre-contrast images (28.0 ± 4.7 vs. 6.9 ± 1.8). No significant differences (p = 0.39) were noted between SNR in pre-contrast and post-contrast liposomal-Gd images of the amniotic fluid, indicating absence of transplacental passage of the agent. The placental margins were significantly (p < 0.001) better visualized on post-contrast liposomal-Gd images. DCE-MRI with the conventional Gd agent demonstrated retrograde opacification of the placenta from fetal edge to the myometrium, consistent with the anatomy of the rat placenta. However, no consistent and reproducible visualization of the retroplacental space was demonstrated on the conventional Gd-enhanced images. The retroplacental space was only visualized on post-contrast T1w images acquired using the liposomal agent (SNR = 15.5 ± 3.4) as a sharply defined, hypo-enhanced interface. The retroplacental space was also visible as a similar hypo-enhancing interface on CE-CT images acquired using a liposomal CT contrast agent. Tissue analysis demonstrated undetectably low transplacental permeation of liposomal-Gd, and was confirmed by lack of permeation through a perfused human placental model. Contrast-enhanced T1w-MRI performed using liposomal-Gd enabled clear visualization of placental margins and delineation of the retroplacental space from the rest of the placenta; the space is undetectable on non-contrast imaging and on post-contrast T1w images acquired using a conventional, clinically approved Gd chelate contrast agent. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Effect of Anesthesia Carrier Gas on In-Vivo Circulation Times of Ultrasound Microbubble Contrast Agents in Rats

    PubMed Central

    Mullin, Lee; Gessner, Ryan; Kwan, James; Kaya, Mehmet; Borden, Mark A.; Dayton, Paul A.

    2012-01-01

    Purpose Microbubble contrast agents are currently implemented in a variety of both clinical and preclinical ultrasound imaging studies. The therapeutic and diagnostic capabilities of these contrast agents are limited by their short in-vivo lifetimes, and research to lengthen their circulation times is ongoing. In this manuscript, observations are presented from a controlled experiment performed to evaluate differences in circulation times for lipid shelled perfluorocarbon-filled contrast agents circulating within rodents as a function of inhaled anesthesia carrier gas. Methods The effects of two common anesthesia carrier gas selections - pure oxygen and medical air – were observed within five rats. Contrast agent persistence within the kidney was measured and compared for oxygen and air anesthesia carrier gas for six bolus contrast injections in each animal. Simulations were performed to examine microbubble behavior with changes in external environment gases. Results A statistically significant extension of contrast circulation time was observed for animals breathing medical air compared to breathing pure oxygen. Simulations support experimental observations and indicate that enhanced contrast persistence may be explained by reduced ventilation/perfusion mismatch and classical diffusion, in which nitrogen plays a key role by contributing to the volume and diluting other gas species in the microbubble gas core. Conclusion: Using medical air in place of oxygen as the carrier gas for isoflurane anesthesia can increase the circulation lifetime of ultrasound microbubble contrast agents. PMID:21246710

  20. Geometrically confined ultrasmall gadolinium oxide nanoparticles boost the T1 contrast ability

    NASA Astrophysics Data System (ADS)

    Ni, Kaiyuan; Zhao, Zhenghuan; Zhang, Zongjun; Zhou, Zijian; Yang, Li; Wang, Lirong; Ai, Hua; Gao, Jinhao

    2016-02-01

    High-performance magnetic resonance imaging (MRI) contrast agents and novel contrast enhancement strategies are urgently needed for sensitive and accurate diagnosis. Here we report a strategy to construct a new T1 contrast agent based on the Solomon-Bloembergen-Morgan (SBM) theory. We loaded the ultrasmall gadolinium oxide nanoparticles into worm-like interior channels of mesoporous silica nanospheres (Gd2O3@MSN nanocomposites). This unique structure endows the nanocomposites with geometrical confinement, high molecular tumbling time, and a large coordinated number of water molecules, which results in a significant enhancement of the T1 contrast with longitudinal proton relaxivity (r1) as high as 45.08 mM-1 s-1. Such a high r1 value of Gd2O3@MSN, compared to those of ultrasmall Gd2O3 nanoparticles and gadolinium-based clinical contrast agents, is mainly attributed to the strong geometrical confinement effect. This strategy provides new guidance for developing various high-performance T1 contrast agents for sensitive imaging and disease diagnosis.High-performance magnetic resonance imaging (MRI) contrast agents and novel contrast enhancement strategies are urgently needed for sensitive and accurate diagnosis. Here we report a strategy to construct a new T1 contrast agent based on the Solomon-Bloembergen-Morgan (SBM) theory. We loaded the ultrasmall gadolinium oxide nanoparticles into worm-like interior channels of mesoporous silica nanospheres (Gd2O3@MSN nanocomposites). This unique structure endows the nanocomposites with geometrical confinement, high molecular tumbling time, and a large coordinated number of water molecules, which results in a significant enhancement of the T1 contrast with longitudinal proton relaxivity (r1) as high as 45.08 mM-1 s-1. Such a high r1 value of Gd2O3@MSN, compared to those of ultrasmall Gd2O3 nanoparticles and gadolinium-based clinical contrast agents, is mainly attributed to the strong geometrical confinement effect. This strategy provides new guidance for developing various high-performance T1 contrast agents for sensitive imaging and disease diagnosis. Electronic supplementary information (ESI) available: Supplementary Fig. S1-S6. See DOI: 10.1039/c5nr08402d

  1. A study of oral contrast coating on the surface of polyps: an implication for computer-aided detection and classification of polyps

    NASA Astrophysics Data System (ADS)

    Singh, Harmanpreet; Li, Lihong C.; Pomeroy, Marc; Pickhardt, Perry J.; Barish, Matthew A.; Harrington, Donald P.; Liang, Zhengrong

    2017-03-01

    Accurate identification of polyps is the ultimate goal of Computed Tomography Colonography (CTC). While oral contrast agents were originally used to tag stool and fluid for the ultimate goal of CTC, recently their effect on coating the surface of polyps has been observed. This study aims to evaluate (1) the frequency at which the oral contrast adhered to polyp surfaces and (2) if there was a difference in contrast adherence with respect to diverse polyp types. To eliminate gravity as a factor in this study, the polyps in contact with tagged fluid pools, particularly on the bottom of the colon wall were excluded. A total of 150 polyps were selected under the above condition from a CTC database and screened for any adherent contrast on the luminal edge. Among the total, 53% of the screened polyps had adherent contrast. Serrated adenomas and hyperplastic polyps had a higher tagging percentage, 77.80% and 62.50% respectively, than tubular adenomas and tubulovillous adenomas, 44.40% and 43% respectively. Other factors that were analyzed for the effect on coating include size and location of the polyps. The higher tagging percentage of serrated adenomas and hyperplastic polyps may be due to their similar cellular features. The average size of the polyps was 8.9 mm. When the polyps were separated by size into small (5-9mm) and large (10-26mm) groups, the large group had a higher tagging percentage. The polyp types were also classified by location with the major findings being: 1) Tubular adenomas were present in all segments of the colon and 2) that serrated adenomas were present at a higher percentage in the proximal colon. These findings shall facilitate characterizing tagging agents and improve computer aided detection and classification of polyps via CTC.

  2. Gadolinium-based magnetic resonance imaging contrast agents in interventional radiology.

    PubMed

    Atar, Eli

    2004-07-01

    Gadolinium-based agents are widely used in magnetic resonance imaging as contrast agents. These agents are radio-opaque enough for diagnostic imaging of the vascular tree by using digitally subtracted images as well as for imaging of the biliary system and the urinary tract. The recommended doses for gadolinium do not impair renal function or cause adverse reactions in patients with iodine sensitivity; thus patients with such conditions can safely undergo diagnostic angiography, either by MRI angiography or by catheterization using gadolinium as contrast agent, for diagnostic and therapeutic purposes.

  3. In vivo ultrasound visualization of non-occlusive blood clots with thrombin-sensitive contrast agents.

    PubMed

    Nakatsuka, Matthew A; Barback, Christopher V; Fitch, Kirsten R; Farwell, Alexander R; Esener, Sadik C; Mattrey, Robert F; Cha, Jennifer N; Goodwin, Andrew P

    2013-12-01

    The use of microbubbles as ultrasound contrast agents is one of the primary methods to diagnose deep venous thrombosis. However, current microbubble imaging strategies require either a clot sufficiently large to produce a circulation filling defect or a clot with sufficient vascularization to allow for targeted accumulation of contrast agents. Previously, we reported the design of a microbubble formulation that modulated its ability to generate ultrasound contrast from interaction with thrombin through incorporation of aptamer-containing DNA crosslinks in the encapsulating shell, enabling the measurement of a local chemical environment by changes in acoustic activity. However, this contrast agent lacked sufficient stability and lifetime in blood to be used as a diagnostic tool. Here we describe a PEG-stabilized, thrombin-activated microbubble (PSTA-MB) with sufficient stability to be used in vivo in circulation with no change in biomarker sensitivity. In the presence of actively clotting blood, PSTA-MBs showed a 5-fold increase in acoustic activity. Specificity for the presence of thrombin and stability under constant shear flow were demonstrated in a home-built in vitro model. Finally, PSTA-MBs were able to detect the presence of an active clot within the vena cava of a rabbit sufficiently small as to not be visible by current non-specific contrast agents. By activating in non-occlusive environments, these contrast agents will be able to detect clots not diagnosable by current contrast agents. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Iron Oxide as an MRI Contrast Agent for Cell Tracking

    PubMed Central

    Korchinski, Daniel J.; Taha, May; Yang, Runze; Nathoo, Nabeela; Dunn, Jeff F.

    2015-01-01

    Iron oxide contrast agents have been combined with magnetic resonance imaging for cell tracking. In this review, we discuss coating properties and provide an overview of ex vivo and in vivo labeling of different cell types, including stem cells, red blood cells, and monocytes/macrophages. Furthermore, we provide examples of applications of cell tracking with iron contrast agents in stroke, multiple sclerosis, cancer, arteriovenous malformations, and aortic and cerebral aneurysms. Attempts at quantifying iron oxide concentrations and other vascular properties are examined. We advise on designing studies using iron contrast agents including methods for validation. PMID:26483609

  5. Counter-propagating wave interaction for contrast-enhanced ultrasound imaging

    NASA Astrophysics Data System (ADS)

    Renaud, G.; Bosch, J. G.; ten Kate, G. L.; Shamdasani, V.; Entrekin, R.; de Jong, N.; van der Steen, A. F. W.

    2012-11-01

    Most techniques for contrast-enhanced ultrasound imaging require linear propagation to detect nonlinear scattering of contrast agent microbubbles. Waveform distortion due to nonlinear propagation impairs their ability to distinguish microbubbles from tissue. As a result, tissue can be misclassified as microbubbles, and contrast agent concentration can be overestimated; therefore, these artifacts can significantly impair the quality of medical diagnoses. Contrary to biological tissue, lipid-coated gas microbubbles used as a contrast agent allow the interaction of two acoustic waves propagating in opposite directions (counter-propagation). Based on that principle, we describe a strategy to detect microbubbles that is free from nonlinear propagation artifacts. In vitro images were acquired with an ultrasound scanner in a phantom of tissue-mimicking material with a cavity containing a contrast agent. Unlike the default mode of the scanner using amplitude modulation to detect microbubbles, the pulse sequence exploiting counter-propagating wave interaction creates no pseudoenhancement behind the cavity in the contrast image.

  6. Development of a platform for co-registered ultrasound and MR contrast imaging in vivo

    NASA Astrophysics Data System (ADS)

    Chandrana, Chaitanya; Bevan, Peter; Hudson, John; Pang, Ian; Burns, Peter; Plewes, Donald; Chopra, Rajiv

    2011-02-01

    Imaging of the microvasculature is often performed using contrast agents in combination with either ultrasound (US) or magnetic resonance (MR) imaging. Contrast agents are used to enhance medical imaging by highlighting microvascular properties and function. Dynamic signal changes arising from the passage of contrast agents through the microvasculature can be used to characterize different pathologies; however, comparisons across modalities are difficult due to differences in the interactions of contrast agents with the microvasculature. Better knowledge of the relationship of contrast enhancement patterns with both modalities could enable better characterization of tissue microvasculature. We developed a co-registration platform for multi-modal US and MR imaging using clinical imaging systems in order to study the relationship between US and MR contrast enhancement. A preliminary validation study was performed in phantoms to determine the registration accuracy of the platform. In phantoms, the in-plane registration accuracy was measured to be 0.2 ± 0.2 and 0.3 ± 0.2 mm, in the lateral and axial directions, respectively. The out-of-plane registration accuracy was estimated to be 0.5 mm ±0.1. Co-registered US and MR imaging was performed in a rabbit model to evaluate contrast kinetics in different tissue types after bolus injections of US and MR contrast agents. The arrival time of the contrast agent in the plane of imaging was relatively similar for both modalities. We studied three different tissue types: muscle, large vessels and fat. In US, the temporal kinetics of signal enhancement were not strongly dependent on tissue type. In MR, however, due to the different amounts of agent extravasation in each tissue type, tissue-specific contrast kinetics were observed. This study demonstrates the feasibility of performing in vivo co-registered contrast US and MR imaging to study the relationships of the enhancement patterns with each modality.

  7. High-Accuracy Ultrasound Contrast Agent Detection Method for Diagnostic Ultrasound Imaging Systems.

    PubMed

    Ito, Koichi; Noro, Kazumasa; Yanagisawa, Yukari; Sakamoto, Maya; Mori, Shiro; Shiga, Kiyoto; Kodama, Tetsuya; Aoki, Takafumi

    2015-12-01

    An accurate method for detecting contrast agents using diagnostic ultrasound imaging systems is proposed. Contrast agents, such as microbubbles, passing through a blood vessel during ultrasound imaging are detected as blinking signals in the temporal axis, because their intensity value is constantly in motion. Ultrasound contrast agents are detected by evaluating the intensity variation of a pixel in the temporal axis. Conventional methods are based on simple subtraction of ultrasound images to detect ultrasound contrast agents. Even if the subject moves only slightly, a conventional detection method will introduce significant error. In contrast, the proposed technique employs spatiotemporal analysis of the pixel intensity variation over several frames. Experiments visualizing blood vessels in the mouse tail illustrated that the proposed method performs efficiently compared with conventional approaches. We also report that the new technique is useful for observing temporal changes in microvessel density in subiliac lymph nodes containing tumors. The results are compared with those of contrast-enhanced computed tomography. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  8. Quantitative Differences Between the First and Second Injection of Contrast Agent in Contrast-Enhanced Ultrasonography of Feline Kidneys and Spleen.

    PubMed

    Stock, Emmelie; Vanderperren, Katrien; Haers, Hendrik; Duchateau, Luc; Hesta, Myriam; Saunders, Jimmy H

    2017-02-01

    Contrast-enhanced ultrasound is a valuable and safe technique for the evaluation of organ perfusion. Repeated injections of ultrasound contrast agent are often administered during the same imaging session. However, it remains unclear if quantitative differences are present between the consecutive microbubble injections. Therefore, the first and second injection of contrast agent for the left renal cortex, renal medulla and the splenic parenchyma in healthy cats were compared. A lower peak intensity and area under the curve were observed for the first injection of contrast agent in the feline kidney, both for the renal cortex and medulla, and spleen. Moreover, for the renal cortex, the time-intensity curve was steeper after the second injection. Findings from the present study demonstrate that a second injection of contrast agent provides stronger enhancement. The exact mechanism behind our findings remains unclear; however, saturation of the lung macrophages is believed to play an important role. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  9. The use of iohexol as oral contrast for computed tomography of the abdomen and pelvis.

    PubMed

    Horton, Karen M; Fishman, Elliot K; Gayler, Bob

    2008-01-01

    Positive oral contrast agents (high-osmolar iodinated solutions [high-osmolar contrast medium] or barium sulfate suspensions) are used routinely for abdominal computed tomography. However, these agents are not ideal. Patients complain about the taste and, sometimes, refuse to drink the required quantity. Nausea, vomiting, and diarrhea are frequent. In certain clinical indications, either barium suspensions or high-osmolar contrast mediums may be contraindicated. This technical note describes the potential advantages of using low-osmolar iodinated solutions as an oral contrast agent for computed tomography.

  10. Gadolinium-based magnetic resonance contrast agents at 7 Tesla: in vitro T1 relaxivities in human blood plasma.

    PubMed

    Noebauer-Huhmann, Iris M; Szomolanyi, Pavol; Juras, Vladimír; Kraff, Oliver; Ladd, Mark E; Trattnig, Siegfried

    2010-09-01

    PURPOSE/INTRODUCTION: The aim of this study was to determine the T1 relaxivities (r1) of 8 gadolinium (Gd)-based MR contrast agents in human blood plasma at 7 Tesla, compared with 3 Tesla. Eight commercially available Gd-based MR contrast agents were diluted in human blood plasma to concentrations of 0, 0.25, 0.5, 1, and 2 mmol/L. In vitro measurements were performed at 37 degrees C, on a 7 Tesla and on a 3 Tesla whole-body magnetic resonance imaging scanner. For the determination of T1 relaxation times, Inversion Recovery Sequences with inversion times from 0 to 3500 ms were used. The relaxivities were calculated. The r1 relaxivities of all agents, diluted in human blood plasma at body temperature, were lower at 7 Tesla than at 3 Tesla. The values at 3 Tesla were comparable to those published earlier. Notably, in some agents, a minor negative correlation of r1 with a concentration of up to 2 mmol/L could be observed. This was most pronounced in the agents with the highest protein-binding capacity. At 7 Tesla, the in vitro r1 relaxivities of Gd-based contrast agents in human blood plasma are lower than those at 3 Tesla. This work may serve as a basis for the application of Gd-based MR contrast agents at 7 Tesla. Further studies are required to optimize the contrast agent dose in vivo.

  11. Superparamagnetic And Paramagnetic MRI Contrast Agents: Application Of Rapid Magnetic Resonance Imaging To Assess Renal Function

    NASA Astrophysics Data System (ADS)

    Carvlin, Mark J.; Renshaw, Perry F.; Arger, Peter; Kundel, Harold L.; Dougherty, Larry; Axel, Leon; Kassab, Eleanor; Moore, Bethanne

    1988-06-01

    The paramagnetic chelate complex, gadolinium-diethylene-triamine-pentaacetic acid, Gd-DTPA, and superparamagnetic particles, such as those composed of dextran coated magnetite, function as magnetic resonance contrast agents by changing the relaxation rates, 1/T1 and 1/T2. The effects that these agents have upon MR signal intensity are determined by: the inherent biophysical properties of the tissue being imaged, the concentration of the contrast agent and the data acquisition scheme (pulse sequence parameters) employed. Following the time course of MR signal change in the first minutes after the injection of contrast agent(s) allows a dynamic assessment of organ functions in a manner analogous to certain nuclear medicine studies. In order to study renal function, sequential MR fast scan images, gradient echo (TR=35/TE=7 msec, flip angle=25 degrees), were acquired, one every 12 seconds, after intravenous injection of Gd-DTPA and/or dextran-magnetite. Gd-DTPA, which is freely filtered at the glomerulus and is neither secreted nor reabsorbed, provides information concerning renal perfusion, glomerular filtration and tubular concentrating ability. Dextran-magnetite (200 A diameter), which is primarily contained within the intravascular space shortly after injection, provides information on blood flow to and distribution within the kidney. The MR signal change observed after administration of contrast agents varied dramatically depending upon the agents injected and the imaging parameters used. Hence a broad range of physiolgic processes may be described using these techniques, i.e. contrast agent enhanced functional MR examinations.

  12. The Microbial Rosetta Stone Database: A compilation of global and emerging infectious microorganisms and bioterrorist threat agents

    PubMed Central

    Ecker, David J; Sampath, Rangarajan; Willett, Paul; Wyatt, Jacqueline R; Samant, Vivek; Massire, Christian; Hall, Thomas A; Hari, Kumar; McNeil, John A; Büchen-Osmond, Cornelia; Budowle, Bruce

    2005-01-01

    Background Thousands of different microorganisms affect the health, safety, and economic stability of populations. Many different medical and governmental organizations have created lists of the pathogenic microorganisms relevant to their missions; however, the nomenclature for biological agents on these lists and pathogens described in the literature is inexact. This ambiguity can be a significant block to effective communication among the diverse communities that must deal with epidemics or bioterrorist attacks. Results We have developed a database known as the Microbial Rosetta Stone. The database relates microorganism names, taxonomic classifications, diseases, specific detection and treatment protocols, and relevant literature. The database structure facilitates linkage to public genomic databases. This paper focuses on the information in the database for pathogens that impact global public health, emerging infectious organisms, and bioterrorist threat agents. Conclusion The Microbial Rosetta Stone is available at . The database provides public access to up-to-date taxonomic classifications of organisms that cause human diseases, improves the consistency of nomenclature in disease reporting, and provides useful links between different public genomic and public health databases. PMID:15850481

  13. Element-specific spectral imaging of multiple contrast agents: a phantom study

    NASA Astrophysics Data System (ADS)

    Panta, R. K.; Bell, S. T.; Healy, J. L.; Aamir, R.; Bateman, C. J.; Moghiseh, M.; Butler, A. P. H.; Anderson, N. G.

    2018-02-01

    This work demonstrates the feasibility of simultaneous discrimination of multiple contrast agents based on their element-specific and energy-dependent X-ray attenuation properties using a pre-clinical photon-counting spectral CT. We used a photon-counting based pre-clinical spectral CT scanner with four energy thresholds to measure the X-ray attenuation properties of various concentrations of iodine (9, 18 and 36 mg/ml), gadolinium (2, 4 and 8 mg/ml) and gold (2, 4 and 8 mg/ml) based contrast agents, calcium chloride (140 and 280 mg/ml) and water. We evaluated the spectral imaging performances of different energy threshold schemes between 25 to 82 keV at 118 kVp, based on K-factor and signal-to-noise ratio and ranked them. K-factor was defined as the X-ray attenuation in the K-edge containing energy range divided by the X-ray attenuation in the preceding energy range, expressed as a percentage. We evaluated the effectiveness of the optimised energy selection to discriminate all three contrast agents in a phantom of 33 mm diameter. A photon-counting spectral CT using four energy thresholds of 27, 33, 49 and 81 keV at 118 kVp simultaneously discriminated three contrast agents based on iodine, gadolinium and gold at various concentrations using their K-edge and energy-dependent X-ray attenuation features in a single scan. A ranking method to evaluate spectral imaging performance enabled energy thresholds to be optimised to discriminate iodine, gadolinium and gold contrast agents in a single spectral CT scan. Simultaneous discrimination of multiple contrast agents in a single scan is likely to open up new possibilities of improving the accuracy of disease diagnosis by simultaneously imaging multiple bio-markers each labelled with a nano-contrast agent.

  14. Tumor environment changed by combretastatin derivative (Cderiv) pretreatment that leads to effective tumor targeting, MRI studies, and antitumor activity of polymeric micelle carrier systems.

    PubMed

    Shiraishi, Kouichi; Harada, Yoshiko; Kawano, Kumi; Maitani, Yoshie; Hori, Katsuyoshi; Yanagihara, Kazuyoshi; Takigahira, Misato; Yokoyama, Masayuki

    2012-01-01

    To evaluate effect of a vascular disrupting agent, a combretastatin derivative (Cderiv), on tumor targeting for polymeric micelle carrier systems, containing either a diagnostic MRI contrast agent or a therapeutic anticancer drug. Cderiv was pre-administered 72 h before polymeric micelle MRI contrast agent injection. Accumulation of the MRI contrast agent in colon 26 murine tumor was evaluated with or without pretreatment of Cderiv by ICP and MRI. Significantly higher accumulation of the MRI contrast agent was found in tumor tissues when Cderiv was administered at 72 h before MRI contrast agent injection. T(1)-weighted images of the tumor exhibited substantial signal enhancement in tumor area at 24 h after the contrast agent injection. In T(1)-weighted images, remarkable T(1)-signal enhancements were observed in part of tumor, not in whole tumor. These results indicate that Cderiv pretreatment considerably enhanced the permeability of the tumor blood vessels. Antitumor activity of adriamycin encapsulated polymeric micelles with the Cderiv pretreatment suppressed tumor growth in 44As3 human gastric scirrhous carcinoma-bearing nude mice. Pretreatment of Cderiv enhanced tumor permeability, resulting in higher accumulation of polymeric micelle carrier systems in solid tumors.

  15. THREE-DIMENSIONAL MODELING OF THE DYNAMICS OF THERAPEUTIC ULTRASOUND CONTRAST AGENTS

    PubMed Central

    Hsiao, Chao-Tsung; Lu, Xiaozhen; Chahine, Georges

    2010-01-01

    A 3-D thick-shell contrast agent dynamics model was developed by coupling a finite volume Navier-Stokes solver and a potential boundary element method flow solver to simulate the dynamics of thick-shelled contrast agents subjected to pressure waves. The 3-D model was validated using a spherical thick-shell model validated by experimental observations. We then used this model to study shell break-up during nonspherical deformations resulting from multiple contrast agent interaction or the presence of a nearby solid wall. Our simulations indicate that the thick viscous shell resists the contrast agent from forming a re-entrant jet, as normally observed for an air bubble oscillating near a solid wall. Instead, the shell thickness varies significantly from location to location during the dynamics, and this could lead to shell break-up caused by local shell thinning and stretching. PMID:20950929

  16. GADOLINIUM(Gd)-BASED and Ion Oxide Nanoparticle Contrast Agents for Pre-Clinical and Clinical Magnetic Resonance Imaging (mri) Research

    NASA Astrophysics Data System (ADS)

    Ng, Thian C.

    2012-06-01

    It is known that one strength of MRI is its excellent soft tissue discrimination. It naturally provides sufficient contrast between the structural differences of normal and pathological tissues, their spatial extent and progression. However, to further extend its applications and enhance even more contrast for clinical studies, various Gadolinium (Gd)-based contrast agents have been developed for different organs (brain strokes, cancer, cardio-MRI, etc). These Gd-based contrast agents are paramagnetic compounds that have strong T1-effect for enhancing the contrast between tissue types. Gd-contrast can also enhance magnetic resonance angiography (CE-MRA) for studying stenosis and for measuring perfusion, vascular susceptibility, interstitial space, etc. Another class of contrast agents makes use of ferrite iron oxide nanoparticles (including Superparamagnetic Ion Oxide (SPIO) and Ultrasmall Superparamagnetic Iron Oxide (USPIO)). These nanoparticles have superior magnetic susceptibility effect and produce a drop in signal, namely in T2*-weighted images, useful for the determination of lymph nodes metastases, angiogenesis and arteriosclerosis plaques.

  17. Structural and functional photoacoustic molecular tomography aided by emerging contrast agents

    PubMed Central

    Nie, Liming

    2015-01-01

    Photoacoustic tomography (PAT) can offer structural, functional and molecular contrasts at scalable observation level. By ultrasonically overcoming the strong optical scattering, this imaging technology can reach centimeters penetration depth while retaining high spatial resolution in biological tissue. Recent extensive research has been focused on developing new contrast agents to improve the imaging sensitivity, specificity and efficiency. These emerging materials have substantially accelerated PAT applications in signal sensing, functional imaging, biomarker labeling and therapy monitoring etc. Here, the potentials of different optical probes as PAT contrast agents were elucidated. We first describe the instrumental embodiments and the measured functional parameters, then focus on emerging contrast agent-based PAT applications, and finally discuss the challenges and prospects. PMID:24967718

  18. Biocompatible and high-performance amino acids-capped MnWO4 nanocasting as a novel non-lanthanide contrast agent for X-ray computed tomography and T1-weighted magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Dong, Kai; Liu, Zhen; Liu, Jianhua; Huang, Sa; Li, Zhenhua; Yuan, Qinghai; Ren, Jinsong; Qu, Xiaogang

    2014-01-01

    In the present work, a novel non-lanthanide dual-modality contrast agent, manganese tungstate (MnWO4), has been successfully constructed by a facile and versatile hydrothermal route. With the merits of a high atomic number and a well-positioned K-edge energy of tungsten, our well-prepared non-lanthanide nanoprobes provide a higher contrast efficacy than routine iodine-based agents in clinics. Additionally, the presence of Mn in these nanoparticles endow them with excellent T1-weighted MR imaging capabilities. As an alternative to T2-weighted MRI and CT dual-modality contrast agents, the nanoprobes can provide a positive contrast signal, which prevents confusion with the dark signals from hemorrhage and blood clots. To the best of our knowledge, this is the first report that a non-lanthanide imaging nanoprobe is applied for CT and T1-weighted MRI simultaneously. Moreover, comparing with gadolinium-based T1-weighted MRI and CT dual-modality contrast agents that were associated with nephrogenic systemic fibrosis (NSF), our contrast agents have superior biocompatibility, which is proved by a detailed study of the pharmacokinetics, biodistribution, and in vivo toxicology. Together with excellent dispersibility, high biocompatibility and superior contrast efficacy, these nanoprobes provide detailed and complementary information from dual-modality imaging over traditional single-mode imaging and bring more opportunities to the new generation of non-lanthanide nanoparticulate-based contrast agents.In the present work, a novel non-lanthanide dual-modality contrast agent, manganese tungstate (MnWO4), has been successfully constructed by a facile and versatile hydrothermal route. With the merits of a high atomic number and a well-positioned K-edge energy of tungsten, our well-prepared non-lanthanide nanoprobes provide a higher contrast efficacy than routine iodine-based agents in clinics. Additionally, the presence of Mn in these nanoparticles endow them with excellent T1-weighted MR imaging capabilities. As an alternative to T2-weighted MRI and CT dual-modality contrast agents, the nanoprobes can provide a positive contrast signal, which prevents confusion with the dark signals from hemorrhage and blood clots. To the best of our knowledge, this is the first report that a non-lanthanide imaging nanoprobe is applied for CT and T1-weighted MRI simultaneously. Moreover, comparing with gadolinium-based T1-weighted MRI and CT dual-modality contrast agents that were associated with nephrogenic systemic fibrosis (NSF), our contrast agents have superior biocompatibility, which is proved by a detailed study of the pharmacokinetics, biodistribution, and in vivo toxicology. Together with excellent dispersibility, high biocompatibility and superior contrast efficacy, these nanoprobes provide detailed and complementary information from dual-modality imaging over traditional single-mode imaging and bring more opportunities to the new generation of non-lanthanide nanoparticulate-based contrast agents. Electronic supplementary information (ESI) available: TEM images of MnWO4 nanoparticles synthesized at pH = 7, 180 °C pH = 9, 180 °C pH = 6, 200 °C with various amino acid molecules as capped agents, survey XPS spectra, FTIR spectrum of glycine capped MnWO4 nanorods, photos of glycine capped MnWO4 nanorods in various solutions including PBS, DMEM cell medium, and FBS, in vivo coronal view CT images of a rat before and after intravenous injection of iobitridol at different timed intervals, in vivo CT imaging of the rat one month after intravenous injection of MnWO4 nanorods, CT values of the heart, liver, spleen and kidney of a rat before and after intravenous administration of MnWO4 nanorods and iobitridol at different time intervals, hematology analysis and blood biochemical assay. See DOI: 10.1039/c3nr05455a

  19. A proposed CT contrast agent using carboxybetaine zwitterionic tantalum oxide nanoparticles: Imaging, biological, and physicochemical performance

    PubMed Central

    FitzGerald, Paul F.; Butts, Matthew D.; Roberts, Jeannette C.; Colborn, Robert E.; Torres, Andrew S.; Lee, Brian D.; Yeh, Benjamin M.; Bonitatibus, Peter J.

    2016-01-01

    Objectives To produce and evaluate a proposed computed tomography (CT) contrast agent based on carboxybetaine zwitterionic (CZ) coated soluble tantalum oxide nanoparticles (CZ-TaO NPs). We chose tantalum to provide superior imaging performance compared to current iodine-based clinical CT contrast agents. We developed the CZ coating to provide biological and physical performance similar to that of current iodinated contrast agents. The aim of this study was to evaluate the imaging, biological, and physicochemical performance of this proposed contrast agent compared to clinically-used iodinated agents. Materials and Methods We evaluated CT imaging performance of our CZ-TaO NPs compared to an iodinated agent in live rats, imaged centrally-located within a tissue-equivalent plastic phantom that simulated a large patient. To evaluate vascular contrast enhancement, we scanned the rats’ great vessels at high temporal resolution during and following contrast agent injection. We performed several in vivo CZ-TaO NP studies in healthy rats to evaluate tolerability. These studies included injecting the agent at the anticipated clinical dose (ACD) and at 3 times and 6 times the ACD, followed by longitudinal hematology to assess impact to blood cells and organ function (from 4 hours to 1 week). Kidney histological analysis was performed 48 hours after injection at 3 times the ACD. We measured the elimination half-life of CZ-TaO NPs from blood, and we monitored acute kidney injury biomarkers with a kidney injury assay using urine collected from 4 hours to 1 week. We measured tantalum retention in individual organs and in the whole carcass 48 hours after injection at ACD. CZ-TaO NPs were synthesized and analyzed in detail. We used multi-dimensional nuclear magnetic resonance (NMR) to determine surface functionality of the nanoparticles. We measured nanoparticle size and solution properties (osmolality and viscosity) of the agent over a range of tantalum concentrations, including the high concentrations required for standard clinical CT imaging. Results CT imaging studies demonstrated image contrast improvement of approximately 40–50% using CZ-TaO NPs compared with an iodinated agent injected at the same mass concentration. Blood and organ analyses showed no adverse effects following injection in healthy naïve rats at 3 times the ACD. Retention of tantalum at 48 hours after injection was less than 2% of the injected dose in the whole carcass, which very closely matched the reported retention of existing commercial iodine-based contrast agents. Urine analysis of sensitive markers for acute kidney injury showed no responses at 1 week following injection at 3 times the ACD; however, a moderate response in the neutrophil gelatinase-associated lipocalin (NGAL) biomarker was measured at 24 and 48 hours. Compared to other tantalum oxide nanoparticles reported in the literature, CZ-TaO NPs had relatively low osmolality and viscosity at concentrations >200 mg Ta/mL, and were similar in these physical properties to dimeric iodine-based contrast agents. Conclusions We found that a CZ-TaO NP-based contrast agent is potentially viable for general-purpose clinical CT imaging. Our results suggest that such an agent can be formulated with clinically-viable physicochemical properties, can be biologically safe and cleared rapidly in urine, and can provide substantially improved image contrast at CT compared to current iodinated agents. PMID:27115702

  20. A Proposed Computed Tomography Contrast Agent Using Carboxybetaine Zwitterionic Tantalum Oxide Nanoparticles: Imaging, Biological, and Physicochemical Performance.

    PubMed

    FitzGerald, Paul F; Butts, Matthew D; Roberts, Jeannette C; Colborn, Robert E; Torres, Andrew S; Lee, Brian D; Yeh, Benjamin M; Bonitatibus, Peter J

    2016-12-01

    The aim of this study was to produce and evaluate a proposed computed tomography (CT) contrast agent based on carboxybetaine zwitterionic (CZ)-coated soluble tantalum oxide (TaO) nanoparticles (NPs). We chose tantalum to provide superior imaging performance compared with current iodine-based clinical CT contrast agents. We developed the CZ coating to provide biological and physical performance similar to that of current iodinated contrast agents. In addition, the aim of this study was to evaluate the imaging, biological, and physicochemical performance of this proposed contrast agent compared with clinically used iodinated agents. We evaluated CT imaging performance of our CZ-TaO NPs compared with that of an iodinated agent in live rats, imaged centrally located within a tissue-equivalent plastic phantom that simulated a large patient. To evaluate vascular contrast enhancement, we scanned the rats' great vessels at high temporal resolution during and after contrast agent injection. We performed several in vivo CZ-TaO NP studies in healthy rats to evaluate tolerability. These studies included injecting the agent at the anticipated clinical dose (ACD) and at 3 times and 6 times the ACD, followed by longitudinal hematology to assess impact to blood cells and organ function (from 4 hours to 1 week). Kidney histological analysis was performed 48 hours after injection at 3 times the ACD. We measured the elimination half-life of CZ-TaO NPs from blood, and we monitored acute kidney injury biomarkers with a kidney injury assay using urine collected from 4 hours to 1 week. We measured tantalum retention in individual organs and in the whole carcass 48 hours after injection at ACD. Carboxybetaine zwitterionic TaO NPs were synthesized and analyzed in detail. We used multidimensional nuclear magnetic resonance to determine surface functionality of the NPs. We measured NP size and solution properties (osmolality and viscosity) of the agent over a range of tantalum concentrations, including the high concentrations required for standard clinical CT imaging. Computed tomography imaging studies demonstrated image contrast improvement of approximately 40% to 50% using CZ-TaO NPs compared with an iodinated agent injected at the same mass concentration. Blood and organ analyses showed no adverse effects after injection in healthy naive rats at 3 times the ACD. Retention of tantalum at 48 hours after injection was less than 2% of the injected dose in the whole carcass, which very closely matched the reported retention of existing commercial iodine-based contrast agents. Urine analysis of sensitive markers for acute kidney injury showed no responses at 1 week after injection at 3 times the ACD; however, a moderate response in the neutrophil gelatinase-associated lipocalin biomarker was measured at 24 and 48 hours. Compared with other TaO NPs reported in the literature, CZ-TaO NPs had relatively low osmolality and viscosity at concentrations greater than 200 mg Ta/mL and were similar in these physical properties to dimeric iodine-based contrast agents. We found that a CZ-TaO NP-based contrast agent is potentially viable for general-purpose clinical CT imaging. Our results suggest that such an agent can be formulated with clinically viable physicochemical properties, can be biologically safe and cleared rapidly in urine, and can provide substantially improved image contrast at CT compared with current iodinated agents.

  1. Cationic Contrast Agent Diffusion Differs Between Cartilage and Meniscus.

    PubMed

    Honkanen, Juuso T J; Turunen, Mikael J; Freedman, Jonathan D; Saarakkala, Simo; Grinstaff, Mark W; Ylärinne, Janne H; Jurvelin, Jukka S; Töyräs, Juha

    2016-10-01

    Contrast enhanced computed tomography (CECT) is a non-destructive imaging technique used for the assessment of composition and structure of articular cartilage and meniscus. Due to structural and compositional differences between these tissues, diffusion and distribution of contrast agents may differ in cartilage and meniscus. The aim of this study is to determine the diffusion kinematics of a novel iodine based cationic contrast agent (CA(2+)) in cartilage and meniscus. Cylindrical cartilage and meniscus samples (d = 6 mm, h ≈ 2 mm) were harvested from healthy bovine knee joints (n = 10), immersed in isotonic cationic contrast agent (20 mgI/mL), and imaged using a micro-CT scanner at 26 time points up to 48 h. Subsequently, normalized X-ray attenuation and contrast agent diffusion flux, as well as water, collagen and proteoglycan (PG) contents in the tissues were determined. The contrast agent distributions within cartilage and meniscus were different. In addition, the normalized attenuation and diffusion flux were higher (p < 0.05) in cartilage. Based on these results, diffusion kinematics vary between cartilage and meniscus. These tissue specific variations can affect the interpretation of CECT images and should be considered when cartilage and meniscus are assessed simultaneously.

  2. Renal contrast-enhanced MR angiography: timing errors and accurate depiction of renal artery origins.

    PubMed

    Schmidt, Maria A; Morgan, Robert

    2008-10-01

    To investigate bolus timing artifacts that impair depiction of renal arteries at contrast material-enhanced magnetic resonance (MR) angiography and to determine the effect of contrast agent infusion rates on artifact generation. Renal contrast-enhanced MR angiography was simulated for a variety of infusion schemes, assuming both correct and incorrect timing between data acquisition and contrast agent injection. In addition, the ethics committee approved the retrospective evaluation of clinical breath-hold renal contrast-enhanced MR angiographic studies obtained with automated detection of contrast agent arrival. Twenty-two studies were evaluated for their ability to depict the origin of renal arteries in patent vessels and for any signs of timing errors. Simulations showed that a completely artifactual stenosis or an artifactual overestimation of an existing stenosis at the renal artery origin can be caused by timing errors of the order of 5 seconds in examinations performed with contrast agent infusion rates compatible with or higher than those of hand injections. Lower infusion rates make the studies more likely to accurately depict the origin of the renal arteries. In approximately one-third of all clinical examinations, different contrast agent uptake rates were detected on the left and right sides of the body, and thus allowed us to confirm that it is often impossible to optimize depiction of both renal arteries. In three renal arteries, a signal void was found at the origin in a patent vessel, and delayed contrast agent arrival was confirmed. Computer simulations and clinical examinations showed that timing errors impair the accurate depiction of renal artery origins. (c) RSNA, 2008.

  3. [Adult transient intestinal intussusception: can abdominal CT guide resolution?].

    PubMed

    Stabile Ianora, Amato Antonio; Telegrafo, Michele; Lorusso, Valentina; Rella, Leonarda; Niccoli Asabella, Artor; La Porta, Michele; Moschetta, Marco

    2013-01-01

    The purpose of this study was to evaluate the adult transient intestinal intussusceptions on CT before and after the administration of gastrointestinal contrast material. We evaluated two different gastrointestinal contrast materials: hyperdense and hypodense. In all cases the gastrointestinal contrast agent solved the invaginations. In the group of patients treated with hypodense contrast medium relapses occurred in the short and long term; no recurrence was observed in the other group. CT is useful in the recognition of intestinal intussusception. The gastrointestinal contrast agent could define the real transience of intussusceptions and hyperdense contrast agent could be more effective in short and long term resolution.

  4. Biological and Clinical Aspects of Lanthanide Coordination Compounds

    PubMed Central

    Misra, Sudhindra N.; M., Indira Devi; Shukla, Ram S.

    2004-01-01

    The coordinating chemistry of lanthanides, relevant to the biological, biochemical and medical aspects, makes a significant contribution to understanding the basis of application of lanthanides, particularly in biological and medical systems. The importance of the applications of lanthanides, as an excellent diagnostic and prognostic probe in clinical diagnostics, and an anticancer material, is remarkably increasing. Lanthanide complexes based X-ray contrast imaging and lanthanide chelates based contrast enhancing agents for magnetic resonance imaging (MRI) are being excessively used in radiological analysis in our body systems. The most important property of the chelating agents, in lanthanide chelate complex, is its ability to alter the behaviour of lanthanide ion with which it binds in biological systems, and the chelation markedly modifies the biodistribution and excretion profile of the lanthanide ions. The chelating agents, especially aminopoly carboxylic acids, being hydrophilic, increase the proportion of their complex excreted from complexed lanthanide ion form biological systems. Lanthanide polyamino carboxylate-chelate complexes are used as contrast enhancing agents for Magnetic Resonance Imaging. Conjugation of antibodies and other tissue specific molecules to lanthanide chelates has led to a new type of specific MRI contrast agents and their conjugated MRI contrast agents with improved relaxivity, functioning in the body similar to drugs. Many specific features of contrast agent assisted MRI make it particularly effective for musculoskeletal and cerebrospinal imaging. Lanthanide-chelate contrast agents are effectively used in clinical diagnostic investigations involving cerebrospinal diseases and in evaluation of central nervous system. Chelated lanthanide complexes shift reagent aided 23Na NMR spectroscopic analysis is used in cellular, tissue and whole organ systems. PMID:18365075

  5. Cranial nerve contrast using nerve-specific fluorophores improved by paired-agent imaging with indocyanine green as a control agent

    NASA Astrophysics Data System (ADS)

    Torres, Veronica C.; Vuong, Victoria D.; Wilson, Todd; Wewel, Joshua; Byrne, Richard W.; Tichauer, Kenneth M.

    2017-09-01

    Nerve preservation during surgery is critical because damage can result in significant morbidity. This remains a challenge especially for skull base surgeries where cranial nerves (CNs) are involved because visualization and access are particularly poor in that location. We present a paired-agent imaging method to enhance identification of CNs using nerve-specific fluorophores. Two myelin-targeting imaging agents were evaluated, Oxazine 4 and Rhodamine 800, and coadministered with a control agent, indocyanine green, either intravenously or topically in rats. Fluorescence imaging was performed on excised brains ex vivo, and nerve contrast was evaluated via paired-agent ratiometric data analysis. Although contrast was improved among all experimental groups using paired-agent imaging compared to conventional, solely targeted imaging, Oxazine 4 applied directly exhibited the greatest enhancement, with a minimum 3 times improvement in CNs delineation. This work highlights the importance of accounting for nonspecific signal of targeted agents, and demonstrates that paired-agent imaging is one method capable of doing so. Although staining, rinsing, and imaging protocols need to be optimized, these findings serve as a demonstration for the potential use of paired-agent imaging to improve contrast of CNs, and consequently, surgical outcome.

  6. Anti-EpCAM scFv gadolinium chelate: a novel targeted MRI contrast agent for imaging of colorectal cancer.

    PubMed

    Khantasup, Kannika; Saiviroonporn, Pairash; Jarussophon, Suwatchai; Chantima, Warangkana; Dharakul, Tararaj

    2018-05-08

    The development of targeted contrast agents for magnetic resonance imaging (MRI) facilitates enhanced cancer imaging and more accurate diagnosis. In the present study, a novel contrast agent was developed by conjugating anti-EpCAM humanized scFv with gadolinium chelate to achieve target specificity. The material design strategy involved site-specific conjugation of the chelating agent to scFv. The scFv monomer was linked to maleimide-DTPA via unpaired cysteine at the scFv C-terminus, followed by chelation with gadolinium (Gd). Successful scFv-DTPA conjugation was achieved at 1:10 molar ratio of scFv to maleimide-DTPA at pH 6.5. The developed anti-EpCAM-Gd-DTPA MRI contrast agent was evaluated for cell targeting ability, in vitro serum stability, cell cytotoxicity, relaxivity, and MR contrast enhancement. A high level of targeting efficacy of anti-EpCAM-Gd-DTPA to an EpCAM-overexpressing HT29 colorectal cell was demonstrated by confocal microscopy. Good stability of the contrast agent was obtained and no cytotoxicity was observed in HT29 cells after 48 h incubation with 25-100 µM of Gd. Favorable imaging was obtained using anti-EpCAM-Gd-DTPA, including 1.8-fold enhanced relaxivity compared with Gd-DTPA, and MR contrast enhancement observed after binding to HT29. The potential benefit of this contrast agent for in vivo MR imaging of colorectal cancer, as well as other EpCAM positive cancers, is suggested and warrants further investigation.

  7. Effect of iodinated low-osmolar contrast media on the hemostatic system after intraarterial and intravenous contrast administration.

    PubMed

    Lukasiewicz, A; Lebkowska, U; Galar, M

    2012-01-01

    Some of the adverse clinical effects of intravascular radiological contrast agents include the interference of these contrast media with normal hemostatic processes. The aim of this report was to investigate in vivo whether a non-ionic iodinated contrast agent possess prothrombotic or anticoagulant properties. Hemostatic parameters: vWF (von Willebrand factor), F1+2 (prothrombin fragments 1+2), TAT (thrombin-antithrombin complexes), D-Dimer, β-TG (beta-thromboglobulin) were measured in a group of 35 patients. Blood samples for laboratory investigations were collected before and 30 min after the administration of a iodine contrast agent. There was observed statistically highly significant contrast-induced increase in TAT and F1+2 (p = 0.005 and p = 0.008, respectively). D-Dimer increase and decrease of β-TG and vWF after contrast medium administration were non significant. The volume of contrast medium has no influence on the assessed hemostatic parameters, while the type of contrast medium and/or the route of the contrast administration may significantly affect hemostatic parameters. We found significant effects of non-ionic agents on hemostatic activation. These effects may be important for adverse reactions and for thromboembolic complications.

  8. [Complications due to contrast agent administration: what has been confirmed in prevention?].

    PubMed

    Schönenberger, E; Mühler, M; Dewey, M

    2010-12-01

    Computed tomography (CT) and magnetic resonance imaging (MRI) have been evaluated by internists to be the most important medical innovations. Often, intravenous contrast agent administration is required for answering the clinical questions to CT and MRI. In this review we present an overview of the most common and most important aspects that need to be considered prior to intravenous contrast agent administration. We discuss aspects of renal impairment (contrast-induced nephropathy, nephrogenic systemic fibrosis), allergy-like reactions, hyperthyroidism, and pregnancy and breast-feeding.

  9. Image reconstruction for x-ray K-edge imaging with a photon counting detector

    NASA Astrophysics Data System (ADS)

    Meng, Bo; Cong, Wenxiang; Xi, Yan; Wang, Ge

    2014-09-01

    Contrast agents with high-Z elements have K-absorption edges which significantly change X-ray attenuation coefficients. The K-edge characteristics is different for various kinds of contrast agents, which offers opportunities for material decomposition in biomedical applications. In this paper, we propose a new K-edge imaging method, which not only quantifies a distribution of a contrast agent but also provides an optimized contrast ratio. Our numerical simulation tests demonstrate the feasibility and merits of the proposed methodology.

  10. Contrast-enhanced CT with a High-Affinity Cationic Contrast Agent for Imaging ex Vivo Bovine, Intact ex Vivo Rabbit, and in Vivo Rabbit Cartilage

    PubMed Central

    Stewart, Rachel C.; Bansal, Prashant N.; Entezari, Vahid; Lusic, Hrvoje; Nazarian, Rosalynn M.; Snyder, Brian D.

    2013-01-01

    Purpose: To quantify the affinity of a cationic computed tomography (CT) contrast agent (CA4+) and that of an anionic contrast agent (ioxaglate) to glycosaminoglycans (GAGs) in ex vivo cartilage tissue explants and to characterize the in vivo diffusion kinetics of CA4+ and ioxaglate in a rabbit model. Materials and Methods: All in vivo procedures were approved by the institutional animal care and use committee. The affinities of ioxaglate and CA4+ to GAGs in cartilage (six bovine osteochondral plugs) were quantified by means of a modified binding assay using micro-CT after plug equilibration in serial dilutions of each agent. The contrast agents were administered intraarticularly to the knee joints of five New Zealand white rabbits to determine the in vivo diffusion kinetics and cartilage tissue imaging capabilities. Kinetics of diffusion into the femoral groove cartilage and relative contrast agent uptake into bovine plugs were characterized by means of nonlinear mixed-effects models. Diffusion time constants (τ) were compared by using a Student t test. Results: The uptake of CA4+ in cartilage was consistently over 100% of the reservoir concentration, whereas it was only 59% for ioxaglate. In vivo, the contrast material–enhanced cartilage reached a steady CT attenuation for both CA4+ and ioxaglate, with τ values of 13.8 and 6.5 minutes, respectively (P = .04). The cartilage was easily distinguishable from the surrounding tissues for CA4+ (12 mg of iodine per milliliter); comparatively, the anionic contrast agent provided less favorable imaging results, even when a higher concentration was used (80 mg of iodine per milliliter). Conclusion: The affinity of the cationic contrast agent CA4+ to GAGs enables high-quality imaging and segmentation of ex vivo bovine and rabbit cartilage, as well as in vivo rabbit cartilage. © RSNA, 2012 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12112246/-/DC1 PMID:23192774

  11. Preclinical evaluation of Gd-DTPA and gadomelitol as contrast agents in DCE-MRI of cervical carcinoma interstitial fluid pressure.

    PubMed

    Hompland, Tord; Ellingsen, Christine; Rofstad, Einar K

    2012-11-22

    High interstitial fluid pressure (IFP) in the primary tumor is associated with poor disease-free survival in locally advanced cervical carcinoma. A noninvasive assay is needed to identify cervical cancer patients with highly elevated tumor IFP because these patients may benefit from particularly aggressive treatment. It has been suggested that dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) with gadolinium diethylene-triamine penta-acetic acid (Gd-DTPA) as contrast agent may provide useful information on the IFP of cervical carcinomas. In this preclinical study, we investigated whether DCE-MRI with contrast agents with higher molecular weights (MW) than Gd-DTPA would be superior to Gd-DTPA-based DCE-MRI. CK-160 human cervical carcinoma xenografts were subjected to DCE-MRI with Gd-DTPA (MW of 0.55 kDa) or gadomelitol (MW of 6.5 kDa) as contrast agent before tumor IFP was measured invasively with a Millar SPC 320 catheter. The DCE-MRI was carried out at a spatial resolution of 0.23 × 0.23 × 2.0 mm³ and a time resolution of 14 s by using a 1.5-T whole-body scanner and a slotted tube resonator transceiver coil constructed for mice. Parametric images were derived from the DCE-MRI recordings by using the Tofts iso-directional transport model and the Patlak uni-directional transport model. When gadomelitol was used as contrast agent, significant positive correlations were found between the parameters of both pharmacokinetic models and tumor IFP. On the other hand, significant correlations between DCE-MRI-derived parameters and IFP could not be detected with Gd-DTPA as contrast agent. Gadomelitol is a superior contrast agent to Gd-DTPA in DCE-MRI of the IFP of CK-160 cervical carcinoma xenografts. Clinical studies attempting to develop DCE-MRI-based assays of the IFP of cervical carcinomas should involve contrast agents with higher MW than Gd-DTPA.

  12. Aptamer-Targeted Gold Nanoparticles As Molecular-Specific Contrast Agents for Reflectance Imaging

    PubMed Central

    2008-01-01

    Targeted metallic nanoparticles have shown potential as a platform for development of molecular-specific contrast agents. Aptamers have recently been demonstrated as ideal candidates for molecular targeting applications. In this study, we investigated the development of aptamer-based gold nanoparticles as contrast agents, using aptamers as targeting agents and gold nanoparticles as imaging agents. We devised a novel conjugation approach using an extended aptamer design where the extension is complementary to an oligonucleotide sequence attached to the surface of the gold nanoparticles. The chemical and optical properties of the aptamer−gold conjugates were characterized using size measurements and oligonucleotide quantitation assays. We demonstrate this conjugation approach to create a contrast agent designed for detection of prostate-specific membrane antigen (PSMA), obtaining reflectance images of PSMA(+) and PSMA(−) cell lines treated with the anti-PSMA aptamer−gold conjugates. This design strategy can easily be modified to incorporate multifunctional agents as part of a multimodal platform for reflectance imaging applications. PMID:18512972

  13. A Brief Account of Nanoparticle Contrast Agents for Photoacoustic Imaging

    PubMed Central

    Pan, Dipanjan; Kim, Benjamin; Wang, Lihong V.; Lanza, Gregory M

    2014-01-01

    Photoacoustic imaging (PAI) is a hybrid, nonionizing modality offering excellent spatial resolution, deep penetration, and high soft tissue contrast. In PAI, signal is generated based on the absorption of laser-generated optical energy by endogenous tissues or exogenous contrast agents leading to acoustic emissions detected by an ultrasound transducer. Research in this area over the years has shown that PAI has the ability to provide both physiological and molecular imaging, which can be viewed alone or used in a hybrid modality fashion to extend the anatomic and hemodynamic sensitivities of clinical ultrasound. PAI may be performed using inherent contrast afforded by light absorbing molecules such as hemoglobin, myoglobin, and melanin or exogenous small molecule contrast agent such as near infrared dyes and porphyrins. However, this review summarizes the potential of exogenous nanoparticle-based agents for PAI applications including contrast based on gold particles, carbon nanotubes, and encapsulated copper compounds. PMID:23983210

  14. Radioprotection and contrast agent use in pediatrics: what, how, and when.

    PubMed

    Lancharro Zapata, Á M; Rodríguez, C Marín

    2016-05-01

    It is essential to minimize exposure to ionizing radiation in children for various reasons. The risk of developing a tumor from exposure to a given dose of radiation is greater in childhood. Various strategies can be used to reduce exposure to ionizing radiation. It is fundamental to avoid unnecessary tests and tests that are not indicated, to choose an alternative test that does not use ionizing radiation, and/or to take a series of measures that minimize the dose of radiation that the patient receives, such as avoiding having to repeat tests, using the appropriate projections, using shields, adjusting the protocol (mAs, Kv, or pitch) to the patient's body volume, etc… When contrast agents are necessary, intracavitary ultrasound agents can be used, although the use of ultrasound agents is also being extended to include intravenous administration. In fluoroscopy, contrast agents with low osmolarity must be used, as in CT where we must adjust the dose and speed of injection to the patient's weight and to the caliber of the peripheral line, respectively. In MRI, only three types of contrast agents have been approved for pediatric use. It is sometimes necessary to use double doses or organ-specific contrast agents in certain clinical situations; the safety of contrast agents for these indications has not been proven, so they must be used off label. Copyright © 2016 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  15. Advantages of paramagnetic CEST complexes having slow-to-intermediate water exchange properties as responsive MRI agents

    PubMed Central

    Soesbe, Todd C.; Wu, Yunkou; Sherry, A. Dean

    2012-01-01

    Paramagnetic saturation transfer chemical exchange (PARACEST) complexes are exogenous contrast agents that have great potential to further extend the functional and molecular imaging capabilities of magnetic resonance. Due to the presence of a central paramagnetic lanthanide ion (Ln3+ ≠ La3+, Gd3+, Lu3+) within the chelate, the resonance frequencies of protons and water molecules bound to the PARACEST agent are shifted far away from the bulk water frequency. This large chemical shift combined with an extreme sensitivity to the chemical exchange rate make PARACEST agents ideally suited for reporting significant biological metrics such as temperature, pH, and the presence of metabolites. Also, the ability to turn PARACEST agents “off” and “on” using a frequency selective saturation pulse gives them a distinct advantage over Gd3+-based contrast agents. A current challenge for PARACEST research is translating the promising in vitro results into in vivo systems. This short review article first describes the basic theory behind PARACEST contrast agents, their benefits over other contrast agents, and their applications to magnetic resonance imaging. It then describes some of the recent PARACEST research results. Specifically, pH measurements using water molecule exchange rate modulation, T2-exchange contrast due to water molecule exchange, the use of ultra-short echo times (TE<10 μs) to overcome T2-exchange line-broadening, and the potential application of T2-exchange as a new contrast mechanism for magnetic resonance imaging. PMID:23055299

  16. Contrast agent choice for intravenous coronary angiography

    NASA Astrophysics Data System (ADS)

    Zeman, H. D.; Siddons, D. P.

    1990-05-01

    The screening of the general population for coronary artery disease would be practical if a method existed for visualizing the extent of occlusion after an intravenous injection of contrast agent. Measurements performed with monochromatic synchrotron radiation X-rays and an iodine-containing contrast agent at the Stanford Synchrotron Radiation Laboratory have shown that such an intravenous angiography procedure would be possible with an adequately intense monochromatic X-ray source. Because of the size and cost of synchrotron radiation facilities it would be desirable to make the most efficient use of the intensity available, while reducing as much as possible the radiation dose experienced by the patient. By choosing contrast agents containing elements with a higher atomic number than iodine, it is possible to both improve the image quality and reduce the patient radiation dose, while using the same synchrotron radiation source. By using Si monochromator crystals with a small mosaic spread, it is possible to increase the X-ray flux available for imaging by over an order of magnitude, without any changes in the storage ring or wiggler magnet. The most critical imaging task for intravenous coronary angiography utilizing synchrotron radiation X-rays is visualizing a coronary artery through the left ventricle or aorta which also contain contrast agent. Calculations have been made of the signal to noise ratio expected for this imaging task for various contrast agents with atomic numbers between that of iodine and bismuth. The X-ray energy spectrum of the X-17 superconduction wiggler beam line at the National Synchrotron Light Source at Brookhaven National Laboratory has been used for these calculations. Both perfect Si crystals and Si crystals with a small mosaic spread are considered as monochromators. Contrast agents containing Gd or Yb seem to have about the optimal calculated signal to noise ratio. Gd-DTPA is already approved for use as a contrast agent for magnetic resonance imaging. Experiments have already been performed with Yb-DTPA in animals, and it appears to have a lower toxicity than that of Gd-DTPA. Reported animal experiments with Gd-DOTA contrast agent show no toxicity at all.

  17. Preclinical evaluation of biodegradable macromolecular contrast agents for magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Feng, Yi

    Macromolecular contrast agents have been shown to be superior to small molecular weight contrast agents for MRI in blood pool imaging, tumor diagnosis and grading. However, none has been approved by the FDA because they circulate in the bloodstream much longer than small molecular weight contrast agents and result in high tissue accumulation of toxic Gd(III) ions. Biodegradable macromolecular contrast agents (BMCA) were invented to alleviate the toxic accumulation. They have a cleavable disulfide bond based backbone that can be degraded in vivo and excreted out of the body via renal filtration. Furthermore, the side chain of the backbone can be modified to achieve various degradation rates. Three BMCA, (Gd-DTPA)-cystamine copolymers (GDCC), Gd-DTPA cystine copolymers (GDCP), and Gd-DTPA cystine diethyl ester copolymers (GDCEP), were evaluated as blood pool contrast agents in a rat model. They have excellent blood pool enhancement, preferred pharmacokinetics, and only minimal long-term tissue retention of toxic Gd(III) ions. GDCC and GDCP, the lead agents with desired degradation rates, with molecular weights of 20 KDa and 70 KDa, were chosen for dynamic contrast enhanced MRI (DCE-MRI) to differentiate human prostate tumor models of different malignancy and growth rates. GDCC and GDCP could differentiate these tumor models, providing more accurate estimations of plasma volume, flow leakage rate, and permeability surface area product than a small molecular weight contrast agent Gd-DTPA-BMA when compared to the prototype macromolecular contrast agent albumin-Gd-DTPA. GDCC was favored for its neutral charge side chain and reasonable uptake rate by the tumors. GDCC with a molecular weight of 40 KDa (GDCC-40, above the renal filtration cutoff size) was used to assess the efficacy of two photothermal therapies (interstitial and indocyanine green enhanced). GDCC-40 provided excellent tumor enhancement shortly after its injection. Acute tumor response (4 hr) after therapies was revealed by DCE-MRI using GDCC-40. The region of the tumor with suspicious uptake of GDCC-40 could be correlated to the residual tumor. With only minimum tissue accumulation, BMCA have applications in blood pool imaging, cancer diagnosis, and efficacy assessment of anticancer treatment. Therefore, BMCA are promising for clinical applications.

  18. Enhanced Positive-Contrast Visualization of Paramagnetic Contrast Agents Using Phase Images

    PubMed Central

    Mills, Parker H.; Ahrens, Eric T.

    2009-01-01

    Iron oxide–based MRI contrast agents are increasingly being used to noninvasively track cells, target molecular epitopes, and monitor gene expression in vivo. Detecting regions of contrast agent accumulation can be challenging if resulting contrast is subtle relative to endogenous tissue hypointensities. A postprocessing method is presented that yields enhanced positive-contrast images from the phase map associated with T2*-weighted MRI data. As examples, the method was applied to an agarose gel phantom doped with superparamagnetic iron-oxide nanoparticles and in vivo and ex vivo mouse brains inoculated with recombinant viruses delivering transgenes that induce overexpression of paramagnetic ferritin. Overall, this approach generates images that exhibit a 1- to 8-fold improvement in contrast-to-noise ratio in regions where paramagnetic agents are present compared to conventional magnitude images. This approach can be used in conjunction with conventional T2* pulse sequences, requires no prescans or increased scan time, and can be applied retrospectively to previously acquired data. PMID:19780169

  19. Magnetic nanoparticles in magnetic resonance imaging and diagnostics.

    PubMed

    Rümenapp, Christine; Gleich, Bernhard; Haase, Axel

    2012-05-01

    Magnetic nanoparticles are useful as contrast agents for magnetic resonance imaging (MRI). Paramagnetic contrast agents have been used for a long time, but more recently superparamagnetic iron oxide nanoparticles (SPIOs) have been discovered to influence MRI contrast as well. In contrast to paramagnetic contrast agents, SPIOs can be functionalized and size-tailored in order to adapt to various kinds of soft tissues. Although both types of contrast agents have a inducible magnetization, their mechanisms of influence on spin-spin and spin-lattice relaxation of protons are different. A special emphasis on the basic magnetism of nanoparticles and their structures as well as on the principle of nuclear magnetic resonance is made. Examples of different contrast-enhanced magnetic resonance images are given. The potential use of magnetic nanoparticles as diagnostic tracers is explored. Additionally, SPIOs can be used in diagnostic magnetic resonance, since the spin relaxation time of water protons differs, whether magnetic nanoparticles are bound to a target or not.

  20. Surface impact on nanoparticle-based magnetic resonance imaging contrast agents

    PubMed Central

    Zhang, Weizhong; Liu, Lin; Chen, Hongmin; Hu, Kai; Delahunty, Ian; Gao, Shi; Xie, Jin

    2018-01-01

    Magnetic resonance imaging (MRI) is one of the most widely used diagnostic tools in the clinic. To improve imaging quality, MRI contrast agents, which can modulate local T1 and T2 relaxation times, are often injected prior to or during MRI scans. However, clinically used contrast agents, including Gd3+-based chelates and iron oxide nanoparticles (IONPs), afford mediocre contrast abilities. To address this issue, there has been extensive research on developing alternative MRI contrast agents with superior r1 and r2 relaxivities. These efforts are facilitated by the fast progress in nanotechnology, which allows for preparation of magnetic nanoparticles (NPs) with varied size, shape, crystallinity, and composition. Studies suggest that surface coatings can also largely affect T1 and T2 relaxations and can be tailored in favor of a high r1 or r2. However, the surface impact of NPs has been less emphasized. Herein, we review recent progress on developing NP-based T1 and T2 contrast agents, with a focus on the surface impact. PMID:29721097

  1. Optimizing radiologist e-prescribing of CT oral contrast agent using a protocoling portal.

    PubMed

    Wasser, Elliot J; Galante, Nicholas J; Andriole, Katherine P; Farkas, Cameron; Khorasani, Ramin

    2013-12-01

    The purpose of this study is to quantify the time expenditure associated with radiologist ordering of CT oral contrast media when using an integrated protocoling portal and to determine radiologists' perceptions of the ordering process. This prospective study was performed at a large academic tertiary care facility. Detailed timing information for CT inpatient oral contrast orders placed via the computerized physician order entry (CPOE) system was gathered over a 14-day period. Analyses evaluated the amount of physician time required for each component of the ordering process. Radiologists' perceptions of the ordering process were assessed by survey. Descriptive statistics and chi-square analysis were performed. A total of 96 oral contrast agent orders were placed by 13 radiologists during the study period. The average time necessary to create a protocol for each case was 40.4 seconds (average range by subject, 20.0-130.0 seconds; SD, 37.1 seconds), and the average total time to create and sign each contrast agent order was 27.2 seconds (range, 10.0-50.0 seconds; SD, 22.4 seconds). Overall, 52.5% (21/40) of survey respondents indicated that radiologist entry of oral contrast agent orders improved patient safety. A minority of respondents (15% [6/40]) indicated that contrast agent order entry was either very or extremely disruptive to workflow. Radiologist e-prescribing of CT oral contrast agents using CPOE can be embedded in a protocol workflow. Integration of health IT tools can help to optimize user acceptance and adoption.

  2. A theranostic dental pulp capping agent with improved MRI and CT contrast and biological properties.

    PubMed

    Mastrogiacomo, S; Güvener, N; Dou, W; Alghamdi, H S; Camargo, W A; Cremers, J G O; Borm, P J A; Heerschap, A; Oosterwijk, E; Jansen, J A; Walboomers, X F

    2017-10-15

    Different materials have been used for vital dental pulp treatment. Preferably a pulp capping agent should show appropriate biological performance, excellent handling properties, and a good imaging contrast. These features can be delivered into a single material through the combination of therapeutic and diagnostic agents (i.e. theranostic). Calcium phosphate based composites (CPCs) are potentially ideal candidate for pulp treatment, although poor imaging contrast and poor dentino-inductive properties are limiting their clinical use. In this study, a theranostic dental pulp capping agent was developed. First, imaging properties of the CPC were improved by using a core-shell structured dual contrast agent (csDCA) consisting of superparamagnetic iron oxide (SPIO) and colloidal gold, as MRI and CT contrast agent respectively. Second, biological properties were implemented by using a dentinogenic factor (i.e. bone morphogenetic protein 2, BMP-2). The obtained CPC/csDCA/BMP-2 composite was tested in vivo, as direct pulp capping agent, in a male Habsi goat incisor model. Our outcomes showed no relevant alteration of the handling and mechanical properties (e.g. setting time, injectability, and compressive strength) by the incorporation of csDCA particles. In vivo results proved MRI contrast enhancement up to 7weeks. Incisors treated with BMP-2 showed improved tertiary dentin deposition as well as faster cement degradation as measured by µCT assessment. In conclusion, the presented theranostic agent matches the imaging and regenerative requirements for pulp capping applications. In this study, we combined diagnostic and therapeutic agents in order to developed a theranostic pulp capping agent with enhanced MRI and CT contrast and improved dentin regeneration ability. In our study we cover all the steps from material preparation, mechanical and in vitro characterization, to in vivo study in a goat dental model. To the best of our knowledge, this is the first time that a theranostic pulp capping material have been developed and tested in an in vivo animal model. Our promising results in term of imaging contrast enhancement and of induction of new dentin formation, open a new scenario in the development of innovative dental materials. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  3. Adverse reactions of low osmolar non-ionic and ionic contrast media when used together or separately during percutaneous coronary intervention.

    PubMed

    Juergens, Craig P; Khaing, Aye Mi; McIntyre, Geraldine J; Leung, Dominic Y C; Lo, Sidney T H; Fernandes, Clyne; Hopkins, Andrew P

    2005-09-01

    Due to perceived advantages in the use of non-ionic contrast agents for diagnostic angiography and ionic agents for percutaneous coronary intervention (PCI), patients often receive various combinations of both types of agents. To assess potential adverse effects of non-ionic and ionic contrast media when used together or separately during percutaneous coronary intervention. We retrospectively evaluated the outcomes of 532 patients undergoing percutaneous coronary intervention in our institution. Patients were divided into two groups: those that underwent diagnostic angiography and "follow on" PCI; and those that underwent "planned" PCI. The groups were subdivided on the basis of the use of the ionic agent ioxaglate or the non-ionic agent iopromide during PCI. The frequency of allergic reactions and major adverse cardiac events (MACE) were noted. With respect to the "follow on" group, allergic reactions occurred in 9 of 150 patients (6.0%) who received the combination of ioxaglate and iopromide versus 1 of 93 (1.1%) who only received iopromide (p=0.094). There was no difference with respect to MACE [6 (4.0%) ioxaglate and iopromide versus 4 (4.3%) iopromide alone, p=1.00]. In the "planned" group, 7 of 165 patients (4.2%) receiving ioxaglate had an allergic reaction as opposed 0.0% (0 of 124 patients) in the iopromide group (p=0.021). All contrast reactions were mild. The incidence of a MACE was similar in both groups [1 (0.6%) ioxaglate versus 2 (1.6%) iopromide, p=0.579]. The incidence of allergic reactions was similar if ioxaglate was used alone or in combination with iopromide (p=0.478). Whilst combining ionic and non-ionic contrast agents in the same procedure was not associated with any more adverse reactions than using an ionic contrast agent alone, the ionic contrast agent ioxaglate was associated with the majority of allergic reactions. With respect to choice of contrast agent, using the non-ionic agent iopromide alone for coronary intervention is associated with the lowest risk of an adverse event.

  4. Interleukin 16- (IL-16-) Targeted Ultrasound Imaging Agent Improves Detection of Ovarian Tumors in Laying Hens, a Preclinical Model of Spontaneous Ovarian Cancer.

    PubMed

    Barua, Animesh; Yellapa, Aparna; Bahr, Janice M; Adur, Malavika K; Utterback, Chet W; Bitterman, Pincas; Basu, Sanjib; Sharma, Sameer; Abramowicz, Jacques S

    2015-01-01

    Limited resolution of transvaginal ultrasound (TVUS) scanning is a significant barrier to early detection of ovarian cancer (OVCA). Contrast agents have been suggested to improve the resolution of TVUS scanning. Emerging evidence suggests that expression of interleukin 16 (IL-16) by the tumor epithelium and microvessels increases in association with OVCA development and offers a potential target for early OVCA detection. The goal of this study was to examine the feasibility of IL-16-targeted contrast agents in enhancing the intensity of ultrasound imaging from ovarian tumors in hens, a model of spontaneous OVCA. Contrast agents were developed by conjugating biotinylated anti-IL-16 antibodies with streptavidin coated microbubbles. Enhancement of ultrasound signal intensity was determined before and after injection of contrast agents. Following scanning, ovarian tissues were processed for the detection of IL-16 expressing cells and microvessels. Compared with precontrast, contrast imaging enhanced ultrasound signal intensity significantly in OVCA hens at early (P < 0.05) and late stages (P < 0.001). Higher intensities of ultrasound signals in OVCA hens were associated with increased frequencies of IL-16 expressing cells and microvessels. These results suggest that IL-16-targeted contrast agents improve the visualization of ovarian tumors. The laying hen may be a suitable model to test new imaging agents and develop targeted anti-OVCA therapeutics.

  5. Contrast-enhanced sonography in pediatrics.

    PubMed

    McCarville, M Beth

    2011-05-01

    Microbubble US contrast agents are composed of an outer shell of protein, phospholipid or polymer that encase air or perfluorocarbon gas. These contrast agents have been widely used in adult cardiology patients to improve endocardial border delineation and have been proved safe and well tolerated in this patient population. There is also a growing body of literature elucidating the value of contrast-enhanced sonography to distinguish benign from malignant liver lesions in adults and to characterize non-hepatic adult malignancies. Because these agents have not been approved for pediatric use in many countries, less is known of the value of contrast-enhanced sonography in children. In this review I will discuss several proven and potential pediatric applications of contrast-enhanced sonography.

  6. Direct visualization of gastrointestinal tract with lanthanide-doped BaYbF5 upconversion nanoprobes.

    PubMed

    Liu, Zhen; Ju, Enguo; Liu, Jianhua; Du, Yingda; Li, Zhengqiang; Yuan, Qinghai; Ren, Jinsong; Qu, Xiaogang

    2013-10-01

    Nanoparticulate contrast agents have attracted a great deal of attention along with the rapid development of modern medicine. Here, a binary contrast agent based on PAA modified BaYbF5:Tm nanoparticles for direct visualization of gastrointestinal (GI) tract has been designed and developed via a one-pot solvothermal route. By taking advantages of excellent colloidal stability, low cytotoxicity, and neglectable hemolysis of these well-designed nanoparticles, their feasibility as a multi-modal contrast agent for GI tract was intensively investigated. Significant enhancement of contrast efficacy relative to clinical barium meal and iodine-based contrast agent was evaluated via X-ray imaging and CT imaging in vivo. By doping Tm(3+) ions into these nanoprobes, in vivo NIR-NIR imaging was then demonstrated. Unlike some invasive imaging modalities, non-invasive imaging strategy including X-ray imaging, CT imaging, and UCL imaging for GI tract could extremely reduce the painlessness to patients, effectively facilitate imaging procedure, as well as rationality economize diagnostic time. Critical to clinical applications, long-term toxicity of our contrast agent was additionally investigated in detail, indicating their overall safety. Based on our results, PAA-BaYbF5:Tm nanoparticles were the excellent multi-modal contrast agent to integrate X-ray imaging, CT imaging, and UCL imaging for direct visualization of GI tract with low systemic toxicity. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. A functional form for injected MRI Gd-chelate contrast agent concentration incorporating recirculation, extravasation and excretion

    NASA Astrophysics Data System (ADS)

    Horsfield, Mark A.; Thornton, John S.; Gill, Andrew; Jager, H. Rolf; Priest, Andrew N.; Morgan, Bruno

    2009-05-01

    A functional form for the vascular concentration of MRI contrast agent after intravenous bolus injection was developed that can be used to model the concentration at any vascular site at which contrast concentration can be measured. The form is based on previous models of blood circulation, and is consistent with previously measured data at long post-injection times, when the contrast agent is fully and evenly dispersed in the blood. It allows the first-pass and recirculation peaks of contrast agent to be modelled, and measurement of the absolute concentration of contrast agent at a single time point allows the whole time course to be rescaled to give absolute contrast agent concentration values. This measure of absolute concentration could be performed at a long post-injection time using either MRI or blood-sampling methods. In order to provide a model that is consistent with measured data, it was necessary to include both rapid and slow extravasation, together with excretion via the kidneys. The model was tested on T1-weighted data from the descending aorta and hepatic portal vein, and on T*2-weighted data from the cerebral arteries. Fitting of the model was successful for all datasets, but there was a considerable variation in fit parameters between subjects, which suggests that the formation of a meaningful population-averaged vascular concentration function is precluded.

  8. Connexin 43-targeted T1 contrast agent for MRI diagnosis of glioma.

    PubMed

    Abakumova, Tatiana; Abakumov, Maxim; Shein, Sergey; Chelushkin, Pavel; Bychkov, Dmitry; Mukhin, Vladimir; Yusubalieva, Gaukhar; Grinenko, Nadezhda; Kabanov, Alexander; Nukolova, Natalia; Chekhonin, Vladimir

    2016-01-01

    Glioblastoma multiforme is the most aggressive form of brain tumor. Early and accurate diagnosis of glioma and its borders is an important step for its successful treatment. One of the promising targets for selective visualization of glioma and its margins is connexin 43 (Cx43), which is highly expressed in reactive astrocytes and migrating glioma cells. The purpose of this study was to synthesize a Gd-based contrast agent conjugated with specific antibodies to Cx43 for efficient visualization of glioma C6 in vivo. We have prepared stable nontoxic conjugates of monoclonal antibody to Cx43 and polylysine-DTPA ligands complexed with Gd(III), which are characterized by higher T1 relaxivity (6.5 mM(-1) s(-1) at 7 T) than the commercial agent Magnevist® (3.4 mM(-1) s(-1)). Cellular uptake of Cx43-specific T1 contrast agent in glioma C6 cells was more than four times higher than the nonspecific IgG-contrast agent, as detected by flow cytometry and confocal analysis. MRI experiments showed that the obtained agents could markedly enhance visualization of glioma C6 in vivo after their intravenous administration. Significant accumulation of Cx43-targeted contrast agents in glioma and the peritumoral zone led not only to enhanced contrast but also to improved detection of the tumor periphery. Fluorescence imaging confirmed notable accumulation of Cx43-specific conjugates in the peritumoral zone compared with nonspecific IgG conjugates at 24 h after intravenous injection. All these features of Cx43-targeted contrast agents might be useful for more precise diagnosis of glioma and its borders by MRI. Copyright © 2015 John Wiley & Sons, Ltd.

  9. Biofilm imaging in porous media by laboratory X-Ray tomography: Combining a non-destructive contrast agent with propagation-based phase-contrast imaging tools.

    PubMed

    Carrel, Maxence; Beltran, Mario A; Morales, Verónica L; Derlon, Nicolas; Morgenroth, Eberhard; Kaufmann, Rolf; Holzner, Markus

    2017-01-01

    X-ray tomography is a powerful tool giving access to the morphology of biofilms, in 3D porous media, at the mesoscale. Due to the high water content of biofilms, the attenuation coefficient of biofilms and water are very close, hindering the distinction between biofilms and water without the use of contrast agents. Until now, the use of contrast agents such as barium sulfate, silver-coated micro-particles or 1-chloronaphtalene added to the liquid phase allowed imaging the biofilm 3D morphology. However, these contrast agents are not passive and potentially interact with the biofilm when injected into the sample. Here, we use a natural inorganic compound, namely iron sulfate, as a contrast agent progressively bounded in dilute or colloidal form into the EPS matrix during biofilm growth. By combining a very long source-to-detector distance on a X-ray laboratory source with a Lorentzian filter implemented prior to tomographic reconstruction, we substantially increase the contrast between the biofilm and the surrounding liquid, which allows revealing the 3D biofilm morphology. A comparison of this new method with the method proposed by Davit et al (Davit et al., 2011), which uses barium sulfate as a contrast agent to mark the liquid phase was performed. Quantitative evaluations between the methods revealed substantial differences for the volumetric fractions obtained from both methods. Namely, contrast agent-biofilm interactions (e.g. biofilm detachment) occurring during barium sulfate injection caused a reduction of the biofilm volumetric fraction of more than 50% and displacement of biofilm patches elsewhere in the column. Two key advantages of the newly proposed method are that passive addition of iron sulfate maintains the integrity of the biofilm prior to imaging, and that the biofilm itself is marked by the contrast agent, rather than the liquid phase as in other available methods. The iron sulfate method presented can be applied to understand biofilm development and bioclogging mechanisms in porous materials and the obtained biofilm morphology could be an ideal basis for 3D numerical calculations of hydrodynamic conditions to investigate biofilm-flow coupling.

  10. 75 FR 875 - Guidance for Industry on New Contrast Imaging Indication Considerations for Devices and Approved...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-06

    ... imaging devices for use with imaging contrast agents or radiopharmaceuticals. FDA intends this guidance to..., for medical imaging devices for use with imaging contrast agents or radiopharmaceuticals. Further, the...] Guidance for Industry on New Contrast Imaging Indication Considerations for Devices and Approved Drug and...

  11. Investigation of X-ray permeability of surgical gloves coated with different contrast agents

    PubMed Central

    Kayan, Mustafa; Yaşar, Selçuk; Saygın, Mustafa; Yılmaz, Ömer; Aktaş, Aykut Recep; Kayan, Fatmanur; Türker, Yasin; Çetinkaya, Gürsel

    2016-01-01

    Objective: We aimed to investigate the effectiveness and radiation protection capability of latex gloves coated with various contrast agents as an alternative to lead gloves. Methods: The following six groups were created to evaluate the permeability of X-ray in this experimental study: lead gloves, two different non-ionic contrast media (iopromide 370/100 mg I/mL and iomeprol 400/100 mg I/mL), 10% povidone–iodine (PV–I), 240/240 g/mL barium sulphate and a mixture of equal amounts of all contrast agents. A radiation dose detector was placed in coated latex gloves for each one. The absorption values of radiation from latex gloves coated with various contrast agents were measured and compared with the absorption of radiation from lead gloves. This study was designed as an ‘experimental study’. Results: The mean absorption value of X-ray from lead gloves was 3.0±0.08 µG/s. The mean absorption values of X-ray from latex gloves coated with various contrast agents were 3.7±0.09 µG/s (iopromide 370/100 mg I/mL), 3.6±0.09 µG/s (iomeprol 400/100 mg I/mL), 3.7±0.04 µG/s (PV–I), 3.1±0.07 µG/s (barium sulphate) and 3.8±0.05 µG/s (mixture of all contrast agents). Latex gloves coated with barium sulphate provided the best radiation absorption compared with latex gloves coated with other radiodense contrast agents. Conclusion: Latex gloves coated with barium sulphate may provide protection equivalent to lead gloves. PMID:26680548

  12. VEGFR2-Targeted Ultrasound Imaging Agent Enhances the Detection of Ovarian Tumors at Early Stage in Laying Hens, a Preclinical Model of Spontaneous Ovarian Cancer.

    PubMed

    Barua, Animesh; Yellapa, Aparna; Bahr, Janice M; Machado, Sergio A; Bitterman, Pincas; Basu, Sanjib; Sharma, Sameer; Abramowicz, Jacques S

    2015-07-01

    Tumor-associated neoangiogenesis (TAN) is an early event in ovarian cancer (OVCA) development. Increased expression of vascular endothelial growth factor receptor 2 (VEGFR2) by TAN vessels presents a potential target for early detection by ultrasound imaging. The goal of this study was to examine the suitability of VEGFR2-targeted ultrasound contrast agents in detecting spontaneous OVCA in laying hens. Effects of VEGFR2-targeted contrast agents in enhancing the intensity of ultrasound imaging from spontaneous ovarian tumors in hens were examined in a cross-sectional study. Enhancement in the intensity of ultrasound imaging was determined before and after injection of VEGFR2-targeted contrast agents. All ultrasound images were digitally stored and analyzed off-line. Following scanning, ovarian tissues were collected and processed for histology and detection of VEGFR2-expressing microvessels. Enhancement in visualization of ovarian morphology was detected by gray-scale imaging following injection of VEGFR2-targeted contrast agents. Compared with pre-contrast, contrast imaging enhanced the intensities of ultrasound imaging significantly (p < 0.0001) irrespective of the pathological status of ovaries. In contrast to normal hens, the intensity of ultrasound imaging was significantly (p < 0.0001) higher in hens with early stage OVCA and increased further in hens with late stage OVCA. Higher intensities of ultrasound imaging in hens with OVCA were positively correlated with increased (p < 0.0001) frequencies of VEGFR2-expressing microvessels. The results of this study suggest that VEGFR2-targeted contrast agents enhance the visualization of spontaneous ovarian tumors in hens at early and late stages of OVCA. The laying hen may be a suitable model to test new imaging agents and develop targeted therapeutics. © The Author(s) 2014.

  13. Synthesis and characterization of a smart contrast agent sensitive to calcium.

    PubMed

    Dhingra, Kirti; Maier, Martin E; Beyerlein, Michael; Angelovski, Goran; Logothetis, Nikos K

    2008-08-07

    A novel first-generation Ca2+ sensitive contrast agent, Gd-DOPTRA has been synthesized and characterized. The agent shows approximately 100% relaxivity enhancement upon addition of Ca2+. The agent is selective and sensitive to Ca2+ also in the presence of Mg2+ and Zn2+. The relaxivity studies carried out in physiological fluids prove the prospects of the agent for in vivo measurements.

  14. Targeted Gold Nanoparticle Contrast Agent for Digital Breast Tomosynthesis and Computed Tomography

    DTIC Science & Technology

    2011-03-01

    injection series was repeated with an iodinated contrast agent, Omnipaque 320 (320 mg I/mL). Iodine enhancement was observed immediately post-injection...shape, size, growth rate, and expression level of cell-surface markers. Today, the most commonly used x-ray contrast agents are iodine-based...structural and radiographic properties of the AuNP. (iii) Evaluate the in vivo effect of the nanoparticles: tumor- enhancement , biodistribution, and

  15. Penetrating Colorectal Injuries: Diagnostic Performance of Multidetector CT with Trajectography.

    PubMed

    Dreizin, David; Boscak, Alexis R; Anstadt, Michael J; Tirada, Nikki; Chiu, William C; Munera, Felipe; Bodanapally, Uttam K; Hornick, Michael; Stein, Deborah M

    2016-12-01

    Purpose To determine the diagnostic performance of multidetector computed tomography (CT) with trajectography for penetrating colorectal injuries. Materials and Methods This institutional review board-approved and HIPAA-compliant study was a 6-year blinded retrospective review by two independent readers of 182 consecutive patients who preoperatively underwent 40- or 64-row multidetector CT for penetrating torso trauma below the diaphragm and had surgically confirmed findings. Colorectal perforation was present in 42 patients. Trajectory analysis with postprocessing software was used for all studies. Additional signs evaluated were rectal contrast agent leak, collections of extruded fecal material, mural defect, wall thickening, abnormal enhancement, free fluid or stranding, and free air. The quality of the colorectal contrast agent administration was recorded. Sensitivity, specificity, predictive values, areas under the receiver operating characteristic curves (AUCs), and Cohen κ were determined. Results In patients with rectal contrast agent administration (n = 151), AUCs were 0.90-0.91, which indicated excellent accuracy. Trajectory was sensitive (88%-91%). For single wounds (n = 104), sensitivity of trajectory was 96% for both readers, but was only 80% for multiple wounds (n = 47). Contrast agent leak was highly specific (96%-98%), but insensitive (42%-46%). Improved diagnostic performance was observed in patients with poor colonic distension or opacification. Accuracy remained high (AUC, 0.86-0.99) in the group without rectal contrast agent administration (n = 31). Conclusion Trajectory had excellent sensitivity, while rectal contrast agent leak was specific but insensitive. Sensitivity of trajectory was lower for multiple wounds. Accuracy remained high in patients without rectal contrast agent administration. © RSNA, 2016.

  16. Advantages of paramagnetic chemical exchange saturation transfer (CEST) complexes having slow to intermediate water exchange properties as responsive MRI agents.

    PubMed

    Soesbe, Todd C; Wu, Yunkou; Dean Sherry, A

    2013-07-01

    Paramagnetic chemical exchange saturation transfer (PARACEST) complexes are exogenous contrast agents that have great potential to further extend the functional and molecular imaging capabilities of magnetic resonance. As a result of the presence of a central paramagnetic lanthanide ion (Ln(3+) ≠ La(3+) , Gd(3+) , Lu(3+) ) within the chelate, the resonance frequencies of exchangeable protons bound to the PARACEST agent are shifted far away from the bulk water frequency. This large chemical shift, combined with an extreme sensitivity to the chemical exchange rate, make PARACEST agents ideally suited for the reporting of significant biological metrics, such as temperature, pH and the presence of metabolites. In addition, the ability to turn PARACEST agents 'off' and 'on' using a frequency-selective saturation pulse gives them a distinct advantage over Gd(3+) -based contrast agents. A current challenge for PARACEST research is the translation of the promising in vitro results into in vivo systems. This short review article first describes the basic theory behind PARACEST contrast agents, their benefits over other contrast agents and their applications to MRI. It then describes some of the recent PARACEST research results: specifically, pH measurements using water molecule exchange rate modulation, T2 exchange contrast caused by water molecule exchange, the use of ultrashort TEs (TE < 10 µs) to overcome T2 exchange line broadening and the potential application of T2 exchange as a new contrast mechanism for MRI. Copyright © 2012 John Wiley & Sons, Ltd.

  17. Including the Group Quarters Population in the US Synthesized Population Database

    PubMed Central

    Chasteen, Bernadette M.; Wheaton, William D.; Cooley, Philip C.; Ganapathi, Laxminarayana; Wagener, Diane K.

    2011-01-01

    In 2005, RTI International researchers developed methods to generate synthesized population data on US households for the US Synthesized Population Database. These data are used in agent-based modeling, which simulates large-scale social networks to test how changes in the behaviors of individuals affect the overall network. Group quarters are residences where individuals live in close proximity and interact frequently. Although the Synthesized Population Database represents the population living in households, data for the nation’s group quarters residents are not easily quantified because of US Census Bureau reporting methods designed to protect individuals’ privacy. Including group quarters population data can be an important factor in agent-based modeling because the number of residents and the frequency of their interactions are variables that directly affect modeling results. Particularly with infectious disease modeling, the increased frequency of agent interaction may increase the probability of infectious disease transmission between individuals and the probability of disease outbreaks. This report reviews our methods to synthesize data on group quarters residents to match US Census Bureau data. Our goal in developing the Group Quarters Population Database was to enable its use with RTI’s US Synthesized Population Database in the Modeling of Infectious Diseases Agent Study. PMID:21841972

  18. Diffusion properties of conventional and calcium-sensitive MRI contrast agents in the rat cerebral cortex.

    PubMed

    Hagberg, Gisela E; Mamedov, Ilgar; Power, Anthony; Beyerlein, Michael; Merkle, Hellmut; Kiselev, Valerij G; Dhingra, Kirti; Kubìček, Vojtĕch; Angelovski, Goran; Logothetis, Nikos K

    2014-01-01

    Calcium-sensitive MRI contrast agents can only yield quantitative results if the agent concentration in the tissue is known. The agent concentration could be determined by diffusion modeling, if relevant parameters were available. We have established an MRI-based method capable of determining diffusion properties of conventional and calcium-sensitive agents. Simulations and experiments demonstrate that the method is applicable both for conventional contrast agents with a fixed relaxivity value and for calcium-sensitive contrast agents. The full pharmacokinetic time-course of gadolinium concentration estimates was observed by MRI before, during and after intracerebral administration of the agent, and the effective diffusion coefficient D* was determined by voxel-wise fitting of the solution to the diffusion equation. The method yielded whole brain coverage with a high spatial and temporal sampling. The use of two types of MRI sequences for sampling of the diffusion time courses was investigated: Look-Locker-based quantitative T(1) mapping, and T(1) -weighted MRI. The observation times of the proposed MRI method is long (up to 20 h) and consequently the diffusion distances covered are also long (2-4 mm). Despite this difference, the D* values in vivo were in agreement with previous findings using optical measurement techniques, based on observation times of a few minutes. The effective diffusion coefficient determined for the calcium-sensitive contrast agents may be used to determine local tissue concentrations and to design infusion protocols that maintain the agent concentration at a steady state, thereby enabling quantitative sensing of the local calcium concentration. Copyright © 2014 John Wiley & Sons, Ltd.

  19. Synthesis and Preclinical Characterization of a Cationic Iodinated Imaging Contrast Agent (CA4+) and Its Use for Quantitative Computed Tomography of Ex Vivo Human Hip Cartilage.

    PubMed

    Stewart, Rachel C; Patwa, Amit N; Lusic, Hrvoje; Freedman, Jonathan D; Wathier, Michel; Snyder, Brian D; Guermazi, Ali; Grinstaff, Mark W

    2017-07-13

    Contrast agents that go beyond qualitative visualization and enable quantitative assessments of functional tissue performance represent the next generation of clinically useful imaging tools. An optimized and efficient large-scale synthesis of a cationic iodinated contrast agent (CA4+) is described for imaging articular cartilage. Contrast-enhanced CT (CECT) using CA4+ reveals significantly greater agent uptake of CA4+ in articular cartilage compared to that of similar anionic or nonionic agents, and CA4+ uptake follows Donnan equilibrium theory. The CA4+ CECT attenuation obtained from imaging ex vivo human hip cartilage correlates with the glycosaminoglycan content, equilibrium modulus, and coefficient of friction, which are key indicators of cartilage functional performance and osteoarthritis stage. Finally, preliminary toxicity studies in a rat model show no adverse events, and a pharmacokinetics study documents a peak plasma concentration 30 min after dosing, with the agent no longer present in vivo at 96 h via excretion in the urine.

  20. Magnetic and Plasmonic Contrast Agents in Optical Coherence Tomography

    PubMed Central

    Oldenburg, Amy L.; Blackmon, Richard L.; Sierchio, Justin M.

    2016-01-01

    Optical coherence tomography (OCT) has gained widespread application for many biomedical applications, yet the traditional array of contrast agents used in incoherent imaging modalities do not provide contrast in OCT. Owing to the high biocompatibility of iron oxides and noble metals, magnetic and plasmonic nanoparticles, respectively, have been developed as OCT contrast agents to enable a range of biological and pre-clinical studies. Here we provide a review of these developments within the past decade, including an overview of the physical contrast mechanisms and classes of OCT system hardware addons needed for magnetic and plasmonic nanoparticle contrast. A comparison of the wide variety of nanoparticle systems is also presented, where the figures of merit depend strongly upon the choice of biological application. PMID:27429543

  1. Iodinated contrast media and the role of renal replacement therapy.

    PubMed

    Weisbord, Steven D; Palevsky, Paul M

    2011-05-01

    Iodinated contrast media are among the most commonly used pharmacologic agents in medicine. Although generally highly safe, iodinated contrast media are associated with several adverse effects, most significantly the risk of acute kidney injury, particularly in patients with underlying renal dysfunction. By virtue of their pharmacokinetic characteristics, these contrast agents are efficiently cleared by hemodialysis and to a lesser extent, hemofiltration. This has led to research into the capacity for renal replacement therapies to prevent certain adverse effects of iodinated contrast. This review examines the molecular and pharmacokinetic characteristics of iodinated contrast media and critically analyzes data from past studies on the role of renal replacement therapy to prevent adverse effects of these diagnostic agents. Published by Elsevier Inc.

  2. Contrast-Enhanced Sonography Depicts Spontaneous Ovarian Cancer at Early Stages in a Preclinical Animal Model

    PubMed Central

    Barua, Animesh; Bitterman, Pincas; Bahr, Janice M.; Basu, Sanjib; Sheiner, Eyal; Bradaric, Michael J.; Hales, Dale B.; Luborsky, Judith L.; Abramowicz, Jacques S.

    2011-01-01

    Objective Our goal was to examine the feasibility of using laying hens, a preclinical model of human spontaneous ovarian cancer, in determining the kinetics of an ultrasound contrast agent indicative of ovarian tumor-associated neoangiogenesis in early-stage ovarian cancer. Methods Three-year-old White Leghorn laying hens with decreased ovarian function were scanned before and after intravenous injection of a human serum albumin–perflutren contrast agent at a dose of 5 µL/kg body weight. Gray scale morphologic characteristics, Doppler indices, the arrival time, peak intensity, and wash-out of the contrast agent were recorded and archived on still images and video clips. Hens were euthanized thereafter; sonographic predictions were compared at gross examination; and ovarian tissues were collected. Archived clips were analyzed to determine contrast parameters and Doppler intensities of vessels. A time-intensity curve per hen was drawn, and the area under the curve was derived. Tumor types and the density of ovarian microvessels were determined by histologic examination and immunohistochemistry and compared to sonographic predictions. Results The contrast agent significantly (P < .05) enhanced the visualization of microvessels, which was confirmed by immunohistochemistry. Contrast parameters, including the time of wash-out and area under the curve, were significantly different (P < .05) between ovaries of normal hens and hens with ovarian cancer and correctly detected cancer at earlier stages than the time of peak intensity. Conclusions The laying hen may be a useful animal model for determining ovarian tumor-associated vascular kinetics diagnostic of early-stage ovarian cancer using a contrast agent. This model may also be useful for testing the efficacy of different contrast agents in a preclinical setting. PMID:21357555

  3. Immediate reactions following iodinated contrast media injection: a study of 38 cases.

    PubMed

    Dewachter, Pascale; Laroche, Dominique; Mouton-Faivre, Claudie; Bloch-Morot, Evelyne; Cercueil, Jean-Pierre; Metge, Liliane; Carette, Marie-France; Vergnaud, Marie-Claude; Clément, Olivier

    2011-03-01

    To investigate the pathomechanisms involved in cases of immediate hypersensitivity reactions occurring after the administration of iodinated contrast media. Patients having presented clinical signs of immediate hypersensitivity suggesting allergy after iodinated contrast medium were investigated. Histamine and tryptase concentrations were measured, and/or skin tests were performed. Patients with positive skin tests to the culprit contrast agent were classified as IgE-mediated allergic hypersensitivity (Group I) and patients with negative skin tests as non-allergic hypersensitivity (Group II). 38 patients were included. Most reactions appeared after non-ionic (n = 32). Reactions were more frequently severe following ionic than non-ionic (p = 0.014). Skin testing was not performed in 11 patients. Skin tests with the culprit contrast agent were negative in 26% of the patients (Group II, n = 7) whereas they were found positive with the contrast agent in 73% of the patients (Group I, n = 19). Latex-induced reaction was diagnosed in one patient, and was consequently excluded from the cohort. In Group I, the frequency of cross-reactivity with the other commercialized iodinated contrast media was low (7%). Cardiovascular signs were present in Group I (52.6%, n = 10), and absent in Group II (p = 0.023). Histamine and tryptase concentrations were higher in patients who had cardiovascular signs (p < 0.02). Immediate reactions with clinical signs suggesting allergy along with positive skin tests with the administered contrast agent confirm immediate allergic hypersensitivity (anaphylaxis) to this agent. Consequently, the culprit contrast agent should be definitely avoided as well as cross-reactive ICM in order to prevent further recurrences. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  4. Near infrared spectral polarization imaging of prostate cancer tissues using Cybesin: a receptor-targeted contrast agent

    NASA Astrophysics Data System (ADS)

    Pu, Yang; Wang, W. B.; Tang, G. C.; Liang, Kexian; Achilefu, S.; Alfano, R. R.

    2013-03-01

    Cybesin, a smart contrast agent to target cancer cells, was investigated using a near infrared (NIR) spectral polarization imaging technique for prostate cancer detection. The approach relies on applying a contrast agent that can target cancer cells. Cybesin, as a small ICG-derivative dye-peptide, emit fluorescence between 750 nm and 900 nm, which is in the "tissue optical window". Cybesin was reported targeting the over-expressed bombesin receptors in cancer cells in animal model and the human prostate cancers over-expressing bombesin receptors. The NIR spectral polarization imaging study reported here demonstrated that Cybesin can be used as a smart optical biomarker and as a prostate cancer receptor targeted contrast agent.

  5. [Gadolinium-based contrast agents for magnetic resonance imaging].

    PubMed

    Carrasco Muñoz, S; Calles Blanco, C; Marcin, Javier; Fernández Álvarez, C; Lafuente Martínez, J

    2014-06-01

    Gadolinium-based contrast agents are increasingly being used in magnetic resonance imaging. These agents can improve the contrast in images and provide information about function and metabolism, increasing both sensitivity and specificity. We describe the gadolinium-based contrast agents that have been approved for clinical use, detailing their main characteristics based on their chemical structure, stability, and safety. In general terms, these compounds are safe. Nevertheless, adverse reactions, the possibility of nephrotoxicity from these compounds, and the possibility of developing nephrogenic systemic fibrosis will be covered in this article. Lastly, the article will discuss the current guidelines, recommendations, and contraindications for their clinical use, including the management of pregnant and breast-feeding patients. Copyright © 2014 SERAM. Published by Elsevier Espana. All rights reserved.

  6. A review of responsive MRI contrast agents: 2005–2014

    PubMed Central

    Hingorani, Dina V.; Bernstein, Adam S.; Pagel, Mark D.

    2014-01-01

    This review focuses on MRI contrast agents that are responsive to a change in a physiological biomarker. The response mechanisms are dependent on six physicochemical characteristics, including the accessibility of water to the agent, tumbling time, proton exchange rate, electron spin state, MR frequency, or superparamagnetism of the agent. These characteristics can be affected by changes in concentrations or activities of enzymes, proteins, nucleic acids, metabolites, or metal ions, or changes in redox state, pH, temperature, or light. A total of 117 examples are presented, including examples that employ nuclei other than 1H, which attests to the creativity of multidisciplinary research efforts to develop responsive MRI contrast agents. PMID:25355685

  7. In vivo tumor characterization using both MR and optical contrast agents with a hybrid MRI-DOT system

    NASA Astrophysics Data System (ADS)

    Lin, Yuting; Ghijsen, Michael; Thayer, David; Nalcioglu, Orhan; Gulsen, Gultekin

    2011-03-01

    Dynamic contrast enhanced MRI (DCE-MRI) has been proven to be the most sensitive modality in detecting breast lesions. Currently available MR contrast agent, Gd-DTPA, is a low molecular weight extracellular agent and can diffuse freely from the vascular space into interstitial space. Due to this reason, DCE-MRI has low sensitivity in differentiating benign and malignant tumors. Meanwhile, diffuse optical tomography (DOT) can be used to provide enhancement kinetics of an FDA approved optical contrast agent, ICG, which behaves like a large molecular weight optical agent due to its binding to albumin. The enhancement kinetics of ICG may have a potential to distinguish between the malignant and benign tumors and hence improve the specificity. Our group has developed a high speed hybrid MRI-DOT system. The DOT is a fully automated, MR-compatible, multi-frequency and multi-spectral imaging system. Fischer-344 rats bearing subcutaneous R3230 tumor are injected simultaneously with Gd-DTPA (0.1nmol/kg) and IC-Green (2.5mg/kg). The enhancement kinetics of both contrast agents are recorded simultaneously with this hybrid MRI-DOT system and evaluated for different tumors.

  8. Gadolinium Endohedral Metallofullerene-Based MRI Contrast Agents

    NASA Astrophysics Data System (ADS)

    Bolskar, Robert D.

    With the ability to encapsulate and carry the highly paramagnetic Gd3+ ion, gadolinium endohedral metallofullerenes or "gadofullerenes" are being explored as alternatives to the chelate complexes that are currently used for contrast-enhanced magnetic resonance imaging (MRI). Reviewed here are the various water-soluble derivatives of the gadofullerenes Gd@C82, Gd@C60, and Gd3N@C80 that have been investigated as MRI contrast agents. The water proton r1 relaxivities of gadofullerenes can be more than an order of magnitude higher than those of clinically used chelate agents. Gadofullerene relaxivity mechanisms have been studied, and multiple factors are found to contribute to their high relaxivities. In vitro and in vivoT1-weighted MRI tests of gadofullerene derivatives have shown their utility as bright image-enhancing agents. The gadofullerene MRI contrast agents are a promising new and unique style of gadolinium carrier for advanced imaging applications, including cellular and molecular imaging.

  9. Nephrogenic systemic fibrosis (NSF): a late adverse reaction to some of the gadolinium based contrast agents

    PubMed Central

    Marckmann, Peter; Logager, Vibeke B.

    2007-01-01

    Abstract Until recently it was believed that extracellular gadolinium based contrast agents were safe for both the kidneys and all other organs within the dose range up to 0.3 mmol/kg body weight. However, in 2006, it was demonstrated that some gadolinium based contrast agents may trigger the development of nephrogenic systemic fibrosis, a generalised fibrotic disorder, in renal failure patients. Accordingly, the use of gadodiamide and gadopentate dimeglumine for renal failure patients was banned in Europe in spring 2007. The same two compounds should only be used cautiously in patients with moderate renal dysfunction. The current paper reviews the situation (July 2007) regarding gadolinium based contrast agent and the severe delayed reaction to some of these agents. The fear of nephrogenic systemic fibrosis should not lead to a denial of a well indicated enhanced magnetic resonance imaging examination. PMID:17905680

  10. Characterization of image heterogeneity using 2D Minkowski functionals increases the sensitivity of detection of a targeted MRI contrast agent.

    PubMed

    Canuto, Holly C; McLachlan, Charles; Kettunen, Mikko I; Velic, Marko; Krishnan, Anant S; Neves, Andre' A; de Backer, Maaike; Hu, D-E; Hobson, Michael P; Brindle, Kevin M

    2009-05-01

    A targeted Gd(3+)-based contrast agent has been developed that detects tumor cell death by binding to the phosphatidylserine (PS) exposed on the plasma membrane of dying cells. Although this agent has been used to detect tumor cell death in vivo, the differences in signal intensity between treated and untreated tumors was relatively small. As cell death is often spatially heterogeneous within tumors, we investigated whether an image analysis technique that parameterizes heterogeneity could be used to increase the sensitivity of detection of this targeted contrast agent. Two-dimensional (2D) Minkowski functionals (MFs) provided an automated and reliable method for parameterization of image heterogeneity, which does not require prior assumptions about the number of regions or features in the image, and were shown to increase the sensitivity of detection of the contrast agent as compared to simple signal intensity analysis. (c) 2009 Wiley-Liss, Inc.

  11. MRI contrast agent concentration and tumor interstitial fluid pressure.

    PubMed

    Liu, L J; Schlesinger, M

    2016-10-07

    The present work describes the relationship between tumor interstitial fluid pressure (TIFP) and the concentration of contrast agent for dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). We predict the spatial distribution of TIFP based on that of contrast agent concentration. We also discuss the cases for estimating tumor interstitial volume fraction (void fraction or porosity of porous medium), ve, and contrast volume transfer constant, K(trans), by measuring the ratio of contrast agent concentration in tissue to that in plasma. A linear fluid velocity distribution may reflect a quadratic function of TIFP distribution and lead to a practical method for TIFP estimation. To calculate TIFP, the parameters or variables should preferably be measured along the direction of the linear fluid velocity (this is in the same direction as the gray value distribution of the image, which is also linear). This method may simplify the calculation for estimating TIFP. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  12. In vitro and ex vivo evaluation of silica-coated super paramagnetic iron oxide nanoparticles (SPION) as biomedical photoacoustic contrast agent

    NASA Astrophysics Data System (ADS)

    Alwi, Rudolf; Telenkov, Sergey A.; Mandelis, Andreas; Leshuk, Timothy; Gu, Frank; Oladepo, Sulayman; Michaelian, Kirk; Dickie, Kristopher

    2013-03-01

    The employment of contrast agents in photoacoustic imaging has gained significant attention within the past few years for their biomedical applications. In this study, the use of silica-coated superparamagnetic iron oxide (Fe3O4) nanoparticles (SPION) was investigated as a contrast agent in biomedical photoacoustic imaging. SPIONs have been widely used as Food-and-Drug-Administration (FDA)-approved contrast agents for magnetic resonance imaging (MRI) and are known to have an excellent safety profile. Using our frequency-domain photoacoustic correlation technique ("the photoacoustic radar") with modulated laser excitation, we examined the effects of nanoparticle size, concentration and biological medium (e.g. serum, sheep blood) on its photoacoustic response in turbid media (intralipid solution). Maximum detection depth and minimum measurable SPION concentration were determined experimentally. The detection was performed using a single element transducer. The nanoparticle-induced optical contrast ex vivo in dense muscular tissues (avian pectus) was evaluated using a phased array photoacoustic probe and the strong potential of silicacoated SPION as a possible photoacoustic contrast agent was demonstrated. This study opens the way for future clinical applications of nanoparticle-enhanced photoacoustic imaging in cancer therapy.

  13. Applying tattoo dye as a third-harmonic generation contrast agent for in vivo optical virtual biopsy of human skin

    NASA Astrophysics Data System (ADS)

    Tsai, Ming-Rung; Lin, Chen-Yu; Liao, Yi-Hua; Sun, Chi-Kuang

    2013-02-01

    Third-harmonic generation (THG) microscopy has been reported to provide intrinsic contrast in elastic fibers, cytoplasmic membrane, nucleus, actin filaments, lipid bodies, hemoglobin, and melanin in human skin. For advanced molecular imaging, exogenous contrast agents are developed for a higher structural or molecular specificity. We demonstrate the potential of the commonly adopted tattoo dye as a THG contrast agent for in vivo optical biopsy of human skin. Spectroscopy and microscopy experiments were performed on cultured cells with tattoo dyes, in tattooed mouse skin, and in tattooed human skin to demonstrate the THG enhancement effect. Compared with other absorbing dyes or nanoparticles used as exogenous THG contrast agents, tattoo dyes are widely adopted in human skin so that future clinical biocompatibility evaluation is relatively achievable. Combined with the demonstrated THG enhancement effect, tattoo dyes show their promise for future clinical imaging applications.

  14. Comparison of colonic transit between polyethylene glycol and water as oral contrast vehicles in the CT evaluation of acute appendicitis.

    PubMed

    Hebert, Jeffrey J; Taylor, Andrew J; Winter, Thomas C

    2006-11-01

    The objective of our study was to assess the efficacy of a new positive oral contrast agent's ability to reach the colon during CT evaluation of acute appendicitis. Eighty adult emergency department patients who underwent abdominal CT to evaluate for appendicitis were studied. Forty patients received the department's standard dose of 1,600 mL of a water-iodinated contrast mixture (ratio of 2 mL of iodinated contrast material to 100 mL of water) with a standard delay time of 2-2.5 hours from the beginning of contrast medium ingestion. Forty patients were given a new oral contrast mixture of 1,000 mL of polyethylene glycol (PEG) mixed with 30 mL of iodinated contrast agent, and the examination was conducted only 1 hour from inception of contrast administration. Examinations were reviewed for the presence of contrast medium in the cecum and the presence of appendicitis or other abdominal abnormality. Thirty-eight of 40 patients in the PEG group had contrast medium in the colon at 1 hour after contrast administration, 20 of whom had surgically confirmed cases of appendicitis. In five other patients in that group, another cause to explain the patient's complaints was identified on imaging. Only 18 of the 40 patients who received the standard oral preparation had contrast material present in the cecum. Eleven patients in that group had confirmed appendicitis, and four others had another abnormal finding detected at CT. There was a significant difference in the success of contrast medium transit to the colon with these two agents (p < 0.0001). The use of an oral contrast agent composed of PEG and iodinated contrast material provided a marked improvement in oral agent transit to the colon even in patients with intraabdominal inflammation.

  15. Poly(iohexol) nanoparticles as contrast agents for in vivo X-ray computed tomography imaging.

    PubMed

    Yin, Qian; Yap, Felix Y; Yin, Lichen; Ma, Liang; Zhou, Qin; Dobrucki, Lawrence W; Fan, Timothy M; Gaba, Ron C; Cheng, Jianjun

    2013-09-18

    Biocompatible poly(iohexol) nanoparticles, prepared through cross-linking of iohexol and hexamethylene diisocyanate followed by coprecipitation of the resulting cross-linked polymer with mPEG-polylactide, were utilized as contrast agents for in vivo X-ray computed tomography (CT) imaging. Compared to conventional small-molecule contrast agents, poly(iohexol) nanoparticles exhibited substantially protracted retention within the tumor bed and a 36-fold increase in CT contrast 4 h post injection, which makes it possible to acquire CT images with improved diagnosis accuracy over a broad time frame without multiple administrations.

  16. Copper complexes as a source of redox active MRI contrast agents.

    PubMed

    Dunbar, Lynsey; Sowden, Rebecca J; Trotter, Katherine D; Taylor, Michelle K; Smith, David; Kennedy, Alan R; Reglinski, John; Spickett, Corinne M

    2015-10-01

    The study reports an advance in designing copper-based redox sensing MRI contrast agents. Although the data demonstrate that copper(II) complexes are not able to compete with lanthanoids species in terms of contrast, the redox-dependent switch between diamagnetic copper(I) and paramagnetic copper(II) yields a novel redox-sensitive contrast moiety with potential for reversibility.

  17. Subharmonic emissions from microbubbles: effect of the driving pulse shape.

    PubMed

    Biagi, Elena; Breschi, Luca; Vannacci, Enrico; Masotti, Leonardo

    2006-11-01

    The aims of this work are to investigate the response of the ultrasonic contrast agents (UCA) insonified by different arbitrary-shaped pulses at different acoustic pressures and concentration of the contrast agent focusing on subharmonic emission. A transmission setup was developed in order to insonify the contrast agent contained in a measurement chamber. The transmitted ultrasonic signals were generated by an arbitrary wave generator connected to a linear power amplifier able to drive a single-element transducer. The transmitted ultrasonic pulses that passed through the contrast agent-filled chamber were received by a second transducer or a hydrophone aligned with the first one. The radio frequency (RF) signals were acquired by fast echographic multiparameters multi-image novel apparatus (FEMMINA), which is an echographic platform able to acquire ultrasonic signals in a real-time modality. Three sets of ultrasonic signals were devised in order to evaluate subharmonic response of the contrast agent respect with sinusoidal burst signals used as reference pulses. A decreasing up to 30 dB in subharmonic response was detected for a Gaussian-shaped pulse; differences in subharmonic emission up to 21 dB were detected for a composite pulse (two-tone burst) for different acoustic pressures and concentrations. Results from this experimentation demonstrated that the transmitted pulse shape strongly affects subharmonic emission in spite of a second harmonic one. In particular, the smoothness of the initial portion of the shaped pulses can inhibit subharmonic generation from the contrast agents respect with a reference sinusoidal burst signal. It also was shown that subharmonic generation is influenced by the amplitude and the concentration of the contrast agent for each set of the shaped pulses. Subharmonic emissions that derive from a nonlinear mechanism involving nonlinear coupling among different oscillation modes are strongly affected by the shape of the ultrasonic driving pulse.

  18. Hyperspectral fluorescence imaging with multi wavelength LED excitation

    NASA Astrophysics Data System (ADS)

    Luthman, A. Siri; Dumitru, Sebastian; Quirós-Gonzalez, Isabel; Bohndiek, Sarah E.

    2016-04-01

    Hyperspectral imaging (HSI) can combine morphological and molecular information, yielding potential for real-time and high throughput multiplexed fluorescent contrast agent imaging. Multiplexed readout from targets, such as cell surface receptors overexpressed in cancer cells, could improve both sensitivity and specificity of tumor identification. There remains, however, a need for compact and cost effective implementations of the technology. We have implemented a low-cost wide-field multiplexed fluorescence imaging system, which combines LED excitation at 590, 655 and 740 nm with a compact commercial solid state HSI system operating in the range 600 - 1000 nm. A key challenge for using reflectance-based HSI is the separation of contrast agent fluorescence from the reflectance of the excitation light. Here, we illustrate how it is possible to address this challenge in software, using two offline reflectance removal methods, prior to least-squares spectral unmixing. We made a quantitative comparison of the methods using data acquired from dilutions of contrast agents prepared in well-plates. We then established the capability of our HSI system for non-invasive in vivo fluorescence imaging in small animals using the optimal reflectance removal method. The HSI presented here enables quantitative unmixing of at least four fluorescent contrast agents (Alexa Fluor 610, 647, 700 and 750) simultaneously in living mice. A successful unmixing of the four fluorescent contrast agents was possible both using the pure contrast agents and with mixtures. The system could in principle also be applied to imaging of ex vivo tissue or intraoperative imaging in a clinical setting. These data suggest a promising approach for developing clinical applications of HSI based on multiplexed fluorescence contrast agent imaging.

  19. Fabrication and evaluation of tumor-targeted positive MRI contrast agent based on ultrasmall MnO nanoparticles.

    PubMed

    Huang, Haitao; Yue, Tao; Xu, Ke; Golzarian, Jafar; Yu, Jiahui; Huang, Jin

    2015-07-01

    Gd(III) chelate is currently used as positive magnetic resonance imaging (MRI) contrast agent in clinical diagnosis, but generally induces the risk of nephrogenic systemic fibrosis (NSF) due to the dissociated Gd(3+) from Gd(III) chelates. To develop a novel positive MRI contrast agent with low toxicity and high sensitivity, ultrasmall MnO nanoparticles were PEGylated via catechol-Mn chelation and conjugated with cRGD as active targeting function to tumor. Particularly, the MnO nanoparticles with a size of ca. 5nm were modified by α,β-poly(aspartic acid)-based graft polymer containing PEG and DOPA moieties and, meanwhile, conjugated with cRGD to produce the contrast agent with a size of ca. 100nm and a longitudinal relaxivity (r1) of 10.2mM(-1)S(-1). Such nanoscaled contrast agent integrated passive- and active-targeting function to tumor, and its efficient accumulation behavior in tumor was verified by in vivo distribution study. At the same time, the PEG moiety played a role of hydrophilic coating to improve the biocompatibility and stability under storing and physiological conditions, and especially might guarantee enough circulation time in blood. Moreover, in vivo MRI revealed a good and long-term effect of enhancing MRI signal for as-fabricated contrast agent while cell viability assay proved its acceptable cytotoxicity for MRI application. On the whole, the as-fabricated PEGylated and cRGD-functionalized contrast agent based on ultrasmall MnO nanoparticles showed a great potential to the T1-weighted MRI diagnosis of tumor. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.

  20. Synthesis and characterization of a porphyrazine-Gd(III) MRI contrast agent and in vivo imaging of a breast cancer xenograft model.

    PubMed

    Trivedi, Evan R; Ma, Zhidong; Waters, Emily A; Macrenaris, Keith W; Subramanian, Rohit; Barrett, Anthony G M; Meade, Thomas J; Hoffman, Brian M

    2014-01-01

    Porphyrazines (Pz), or tetraazaporphyrins, are being studied for their potential use in detection and treatment of cancer. Here, an amphiphilic Cu-Pz-Gd(III) conjugate has been prepared via azide-alkyne Huisgen cycloaddition or 'click' chemistry between an azide functionalized Pz and alkyne functionalized DOTA-Gd(III) analog for use as an MRI contrast agent. This agent, Cu-Pz-Gd(III), is synthesized in good yield and exhibits solution-phase ionic relaxivity (r1  = 11.5 mM(-1) s(-1)) that is approximately four times higher than that of a clinically used monomeric Gd(III) contrast agent, DOTA-Gd(III). Breast tumor cells (MDA-MB-231) associate with Cu-Pz-Gd(III) in vitro, where significant contrast enhancement (9.336 ± 0.335 contrast-to-noise ratio) is observed in phantom cell pellet MR images. This novel contrast agent was administered in vivo to an orthotopic breast tumor model in athymic nude mice and MR images were collected. The average T1 of tumor regions in mice treated with 50 mg kg(-1) Cu-Pz-Gd(III) decreased relative to saline-treated controls. Furthermore, the decrease in T1 was persistent relative to mice treated with the monomeric Gd(III) contrast agent. An ex vivo biodistribution study confirmed that Cu-Pz-Gd(III) accumulates in the tumors and is rapidly cleared, primarily through the kidneys. Differential accumulation and T1 enhancement by Cu-Pz-Gd(III) in the tumor's core relative to the periphery offer preliminary evidence that this agent would find application in the imaging of necrotic tissue. Copyright © 2014 John Wiley & Sons, Ltd.

  1. Spectral Imaging Technology-Based Evaluation of Radiation Treatment Planning to Remove Contrast Agent Artifacts.

    PubMed

    Yi-Qun, Xu; Wei, Liu; Xin-Ye, Ni

    2016-10-01

    This study employs dual-source computed tomography single-spectrum imaging to evaluate the effects of contrast agent artifact removal and the computational accuracy of radiotherapy treatment planning improvement. The phantom, including the contrast agent, was used in all experiments. The amounts of iodine in the contrast agent were 30, 15, 7.5, and 0.75 g/100 mL. Two images with different energy values were scanned and captured using dual-source computed tomography (80 and 140 kV). To obtain a fused image, 2 groups of images were processed using single-energy spectrum imaging technology. The Pinnacle planning system was used to measure the computed tomography values of the contrast agent and the surrounding phantom tissue. The difference between radiotherapy treatment planning based on 80 kV, 140 kV, and energy spectrum image was analyzed. For the image with high iodine concentration, the quality of the energy spectrum-fused image was the highest, followed by that of the 140-kV image. That of the 80-kV image was the worst. The difference in the radiotherapy treatment results among the 3 models was significant. When the concentration of iodine was 30 g/100 mL and the distance from the contrast agent at the dose measurement point was 1 cm, the deviation values (P) were 5.95% and 2.20% when image treatment planning was based on 80 and 140 kV, respectively. When the concentration of iodine was 15 g/100 mL, deviation values (P) were -2.64% and -1.69%. Dual-source computed tomography single-energy spectral imaging technology can remove contrast agent artifacts to improve the calculated dose accuracy in radiotherapy treatment planning. © The Author(s) 2015.

  2. Redox-activated MRI contrast agents based on lanthanide and transition metal ions.

    PubMed

    Tsitovich, Pavel B; Burns, Patrick J; McKay, Adam M; Morrow, Janet R

    2014-04-01

    The reduction/oxidation (redox) potential of tissue is tightly regulated in order to maintain normal physiological processes, but is disrupted in disease states. Thus, the development of new tools to map tissue redox potential may be clinically important for the diagnosis of diseases that lead to redox imbalances. One promising area of chemical research is the development of redox-activated probes for mapping tissue through magnetic resonance imaging (MRI). In this review, we summarize several strategies for the design of redox-responsive MRI contrast agents. Our emphasis is on both lanthanide(III) and transition metal(II/III) ion complexes that provide contrast either as T1 relaxivity MRI contrast agents or as paramagnetic chemical exchange saturation transfer (PARACEST) contrast agents. These agents are redox-triggered by a variety of chemical reactions or switches including redox-activated thiol groups, and heterocyclic groups that interact with the metal ion or influence properties of other ancillary ligands. Metal ion centered redox is an approach which is ripe for development by coordination chemists. Redox-triggered metal ion approaches have great potential for creating large differences in magnetic properties that lead to changes in contrast. An attractive feature of these agents is the ease of fine-tuning the metal ion redox potential over a biologically relevant range. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Gadolinium-Loaded Solid Lipid Nanoparticles as a Tumor-Absorbable Contrast Agent for Early Diagnosis of Colorectal Tumors Using Magnetic Resonance Colonography.

    PubMed

    Sun, Jihong; Zhang, Shizheng; Jiang, Shaojie; Bai, Weixian; Liu, Fei; Yuan, Hong; Ji, Jiansong; Luo, Jingfeng; Han, Guocan; Chen, Lumin; Jin, Yin; Hu, Peng; Yu, Lei; Yang, Xiaoming

    2016-09-01

    Magnetic resonance (MR) contrast agents focusing on special functions are required to improve cancer diagnosis, particularly in the early stages. Here, we designed multifunctional solid lipid nanoparticles (SLNs) with simultaneous loading of gadolinium (Gd) diethylenetriaminepentaacetic acid (Gd-DTPA) and octadecylamine fluorescein isothiocyanate (FITC) to obtain Gd-FITC-SLNs as a tumor-absorbable nanoparticle contrast agent for the histological confirmation of MR imaging (MRI) findings. Colorectal tumors were evaluated in vitro and in vivo via direct uptake of this contrast agent, which displayed reasonable T1 relaxivity and no significant cytotoxicity at the experimental concentrations in human colon carcinoma cells (HT29) and mouse colon carcinoma cells (CT26). In vitro cell uptake experiments demonstrated that contrast agent absorption by the two types of cancer cells was concentration-dependent in the safe concentration range. During in vivo MRI, transrectal infusion of Gd-FITC-SLNs showed more significant enhancement at the tumor site compared with the infusion of Gd-DTPA in female C57/BL mice with azoxymethane/dextran sulfate sodium-induced colorectal highgrade intraepithelial neoplasia. Subsequent confocal fluorescence microscopy demonstrated Gd-FITC-SLNs as highly concentrated green fluorescent spots distributed from the tumor capsule into the tumor. This study establishes the "proof-of-principle" of a new MRI technique wherein colorectal tumors are enhanced via direct absorption or uptake of the nanoparticle contrast agent.

  4. Biofilm imaging in porous media by laboratory X-Ray tomography: Combining a non-destructive contrast agent with propagation-based phase-contrast imaging tools

    PubMed Central

    Beltran, Mario A.; Morales, Verónica L.; Derlon, Nicolas; Morgenroth, Eberhard; Kaufmann, Rolf; Holzner, Markus

    2017-01-01

    X-ray tomography is a powerful tool giving access to the morphology of biofilms, in 3D porous media, at the mesoscale. Due to the high water content of biofilms, the attenuation coefficient of biofilms and water are very close, hindering the distinction between biofilms and water without the use of contrast agents. Until now, the use of contrast agents such as barium sulfate, silver-coated micro-particles or 1-chloronaphtalene added to the liquid phase allowed imaging the biofilm 3D morphology. However, these contrast agents are not passive and potentially interact with the biofilm when injected into the sample. Here, we use a natural inorganic compound, namely iron sulfate, as a contrast agent progressively bounded in dilute or colloidal form into the EPS matrix during biofilm growth. By combining a very long source-to-detector distance on a X-ray laboratory source with a Lorentzian filter implemented prior to tomographic reconstruction, we substantially increase the contrast between the biofilm and the surrounding liquid, which allows revealing the 3D biofilm morphology. A comparison of this new method with the method proposed by Davit et al (Davit et al., 2011), which uses barium sulfate as a contrast agent to mark the liquid phase was performed. Quantitative evaluations between the methods revealed substantial differences for the volumetric fractions obtained from both methods. Namely, contrast agent—biofilm interactions (e.g. biofilm detachment) occurring during barium sulfate injection caused a reduction of the biofilm volumetric fraction of more than 50% and displacement of biofilm patches elsewhere in the column. Two key advantages of the newly proposed method are that passive addition of iron sulfate maintains the integrity of the biofilm prior to imaging, and that the biofilm itself is marked by the contrast agent, rather than the liquid phase as in other available methods. The iron sulfate method presented can be applied to understand biofilm development and bioclogging mechanisms in porous materials and the obtained biofilm morphology could be an ideal basis for 3D numerical calculations of hydrodynamic conditions to investigate biofilm-flow coupling. PMID:28732010

  5. Dose Reduction Study in Vaginal Balloon Packing Filled With Contrast for HDR Brachytherapy Treatment;HDR; Uterine cervix cancer; Vaginal balloon packing; Contrast; Monte Carlo

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saini, Amarjit S.; Zhang, Geoffrey G., E-mail: geoffrey.zhang@moffitt.org; Finkelstein, Steven E.

    2011-07-15

    Purpose: Vaginal balloon packing is a means to displace organs at risk during high dose rate brachytherapy of the uterine cervix. We tested the hypothesis that contrast-filled vaginal balloon packing reduces radiation dose to organs at risk, such as the bladder and rectum, in comparison to water- or air-filled balloons. Methods and Materials: In a phantom study, semispherical vaginal packing balloons were filled with air, saline solution, and contrast agents. A high dose rate iridium-192 source was placed on the anterior surface of the balloon, and the diode detector was placed on the posterior surface. Dose ratios were taken withmore » each material in the balloon. Monte Carlo (MC) simulations, by use of the MC computer program DOSXYZnrc, were performed to study dose reduction vs. balloon size and contrast material, including commercially available iodine- and gadolinium-based contrast agents. Results: Measured dose ratios on the phantom with the balloon radius of 3.4 cm were 0.922 {+-} 0.002 for contrast/saline solution and 0.808 {+-} 0.001 for contrast/air. The corresponding ratios by MC simulations were 0.895 {+-} 0.010 and 0.781 {+-} 0.010. The iodine concentration in the contrast was 23.3% by weight. The dose reduction of contrast-filled balloon ranges from 6% to 15% compared with water-filled balloon and 11% to 26% compared with air-filled balloon, with a balloon size range between 1.4 and 3.8 cm, and iodine concentration in contrast of 24.9%. The dose reduction was proportional to the contrast agent concentration. The gadolinium-based contrast agents showed less dose reduction because of much lower concentrations in their solutions. Conclusions: The dose to the posterior wall of the bladder and the anterior wall of the rectum can be reduced if the vaginal balloon is filled with contrast agent in comparison to vaginal balloons filled with saline solution or air.« less

  6. 47 CFR 52.12 - North American Numbering Plan Administrator and B&C Agent.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 3 2014-10-01 2014-10-01 false North American Numbering Plan Administrator and... Administrator and B&C Agent. The North American Numbering Plan Administrator (“NANPA”) and the associated “B&C... rating information, into the industry-approved database(s) for dissemination of such information. This...

  7. 47 CFR 52.12 - North American Numbering Plan Administrator and B&C Agent.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 3 2013-10-01 2013-10-01 false North American Numbering Plan Administrator and... Administrator and B&C Agent. The North American Numbering Plan Administrator (“NANPA”) and the associated “B&C... rating information, into the industry-approved database(s) for dissemination of such information. This...

  8. 47 CFR 52.12 - North American Numbering Plan Administrator and B&C Agent.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 3 2012-10-01 2012-10-01 false North American Numbering Plan Administrator and... Administrator and B&C Agent. The North American Numbering Plan Administrator (“NANPA”) and the associated “B&C... rating information, into the industry-approved database(s) for dissemination of such information. This...

  9. 47 CFR 52.12 - North American Numbering Plan Administrator and B&C Agent.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 3 2011-10-01 2011-10-01 false North American Numbering Plan Administrator and... Administrator and B&C Agent. The North American Numbering Plan Administrator (“NANPA”) and the associated “B&C... rating information, into the industry-approved database(s) for dissemination of such information. This...

  10. Brain tumor enhancement in magnetic resonance imaging at 3 tesla: intraindividual comparison of two high relaxivity macromolecular contrast media with a standard extracellular gd-chelate in a rat brain tumor model.

    PubMed

    Fries, Peter; Runge, Val M; Bücker, Arno; Schürholz, Hellmut; Reith, Wolfgang; Robert, Philippe; Jackson, Carney; Lanz, Titus; Schneider, Günther

    2009-04-01

    The aim of this study was to evaluate lesion enhancement (LE) and contrast-to-noise ratio (CNR) properties of P846, a new intermediate sized, high relaxivity Gd-based contrast agent at 3 Tesla in a rat brain glioma model, and to compare this contrast agent with a high relaxivity, macromolecular compound (P792), and a standard extracellular Gd-chelate (Gd-DOTA). Seven rats with experimental induced brain glioma were evaluated using 3 different contrast agents, with each MR examination separated by at least 24 hours. The time between injections assured sufficient clearance of the agent from the tumor, before the next examination. P792 (Gadomelitol, Guerbet, France) and P846 (a new compound from Guerbet Research) are macromolecular and high relaxivity contrast agents with no protein binding, and were compared with the extracellular agent Gd-DOTA (Dotarem, Guerbet, France). T1w gradient echo sequences (TR/TE 200 milliseconds/7.38 milliseconds, flip angle = 90 degrees , acquisition time: 1:42 minutes:sec, voxel size: 0.2 x 0.2 x 2.0 mm, FOV = 40 mm, acquisition matrix: 256 x 256) were acquired before and at 5 consecutive time points after each intravenous contrast injection in the identical slice orientation, using a dedicated 4-channel head array animal coil. The order of contrast media injection was randomized, with however Gd-DOTA used either as the first or second contrast agent. Contrast agent dose was adjusted to compensate for the different T1 relaxivities of the 3 agents. Signal-to-noise ratio, CNR, and LE were evaluated using region-of-interest analysis. A veterinary histopathologist confirmed the presence of a glioma in each subject, after completion of the imaging study. P792 showed significantly less LE as compared with Gd-DOTA within the first 7 minutes after contrast agent injection (P < 0.05) with, however, reaching comparable LE values at 9 minutes after injection (P = 0.07). However, P792 provided significantly less CNR as compared with Gd-DOTA (P < 0.05) for all examination time points. P846 provided comparable but persistent LE as compared with Gd-DOTA (P < 0.05) and demonstrated significantly greater LE and CNR when compared with P792 (P < 0.05). No statistically significant differences between CNR values for Gd-DOTA and P846 were noted for all examination time points (P < 0.05), with P846 administered at one-fourth the dose as compared with Gd-DOTA. The intravascular contrast medium P792 showed significantly less LE and CNR in comparison to Gd-DOTA and P846, suggesting that it does not show marked extravasation from tumor neocapillaries and does not significantly cross the disrupted blood brain-barrier in this rat glioma model. In distinction, P846 provides comparable enhancement properties at a field strength of 3 Tesla to the extracellular contrast agent Gd-DOTA, using the adjusted dose, suggesting that it crosses the disrupted blood-brain-barrier and tumor capillaries, most likely based on the decreased molecular weight as compared with P792. At the same time, the high relaxivity of this compound allows for decreasing the injected gadolinium dose by a factor of 4 whereas providing comparable enhancement properties when compared with a standard extracellular Gd-chelate (Gd-DOTA) at a dose of 0.1 mmol/kg body weight.

  11. Cystogram

    MedlinePlus

    ... showing the bladder (solid arrow) filling with a contrast agent. The catheter used to fill the bladder also ... taken. This final radiograph will show whether any contrast agent stays in your bladder following urina- tion. Any ...

  12. Evaluation of bowel distension and mural visualisation using neutral oral contrast agents for multidetector-row computed tomography.

    PubMed

    Lim, Bee Kuan; Bux, Shaik Ismail; Rahmat, Kartini; Lam, Sze Yin; Liew, Yew Wai

    2012-11-01

    We compared the effectiveness of different types of non-commercial neutral oral contrast agents for bowel distension and mural visualisation in computed tomographic (CT) enterography. 90 consecutive patients from a group of 108 were randomly assigned to receive water (n = 30), 3.8% milk (n = 30) or 0.1% gastrografin (n = 30) as oral contrast agent. The results were independently reviewed by two radiologists who were blinded to the contrast agents used. The degree of bowel distension was qualitatively scored on a four-point scale. The discrimination of bowel loops, mural visualisation and visualisation of mucosal folds were evaluated on a 'yes' or 'no' basis. Side effects of the various agents were also recorded. 3.8% milk was significantly superior to water for bowel distension (jejunum, ileum and terminal ileum), discrimination of bowel loops (jejunum and ileum), mural visualisation and visualisation of mucosal folds (ileum and terminal ileum). It was also significantly superior to 0.1% gastrografin for bowel distension, discrimination of bowel loops, mural visualisation and visualisation of mucosal folds (jejunum, ileum and terminal ileum). However, 10% of patients who received 3.8% milk reported immediate post-test diarrhoea. No side effects were documented for patients who received water and 0.1% gastrografin. 3.8% milk is an effective and superior neutral oral contrast agent for the assessment of the jejunum, ileum and terminal ileum in CT enterography. However, further studies are needed to explore other suitable oral contrast agents for CT enterography in lactose- or cow's milk-intolerant patients.

  13. High Energy Resolution Hyperspectral X-Ray Imaging for Low-Dose Contrast-Enhanced Digital Mammography.

    PubMed

    Pani, Silvia; Saifuddin, Sarene C; Ferreira, Filipa I M; Henthorn, Nicholas; Seller, Paul; Sellin, Paul J; Stratmann, Philipp; Veale, Matthew C; Wilson, Matthew D; Cernik, Robert J

    2017-09-01

    Contrast-enhanced digital mammography (CEDM) is an alternative to conventional X-ray mammography for imaging dense breasts. However, conventional approaches to CEDM require a double exposure of the patient, implying higher dose, and risk of incorrect image registration due to motion artifacts. A novel approach is presented, based on hyperspectral imaging, where a detector combining positional and high-resolution spectral information (in this case based on Cadmium Telluride) is used. This allows simultaneous acquisition of the two images required for CEDM. The approach was tested on a custom breast-equivalent phantom containing iodinated contrast agent (Niopam 150®). Two algorithms were used to obtain images of the contrast agent distribution: K-edge subtraction (KES), providing images of the distribution of the contrast agent with the background structures removed, and a dual-energy (DE) algorithm, providing an iodine-equivalent image and a water-equivalent image. The high energy resolution of the detector allowed the selection of two close-by energies, maximising the signal in KES images, and enhancing the visibility of details with the low surface concentration of contrast agent. DE performed consistently better than KES in terms of contrast-to-noise ratio of the details; moreover, it allowed a correct reconstruction of the surface concentration of the contrast agent in the iodine image. Comparison with CEDM with a conventional detector proved the superior performance of hyperspectral CEDM in terms of the image quality/dose tradeoff.

  14. Development of silica-encapsulated silver nanoparticles as contrast agents intended for dual-energy mammography.

    PubMed

    Karunamuni, Roshan; Naha, Pratap C; Lau, Kristen C; Al-Zaki, Ajlan; Popov, Anatoliy V; Delikatny, Edward J; Tsourkas, Andrew; Cormode, David P; Maidment, Andrew D A

    2016-09-01

    Dual-energy (DE) mammography has recently entered the clinic. Previous theoretical and phantom studies demonstrated that silver provides greater contrast than iodine for this technique. Our objective was to characterize and evaluate in vivo a prototype silver contrast agent ultimately intended for DE mammography. The prototype silver contrast agent was synthesized using a three-step process: synthesis of a silver core, silica encapsulation and PEG coating. The nanoparticles were then injected into mice to determine their accumulation in various organs, blood half-life and dual-energy contrast. All animal procedures were approved by the institutional animal care and use committee. The final diameter of the nanoparticles was measured to be 102 (±9) nm. The particles were removed from the vascular circulation with a half-life of 15 min, and accumulated in macrophage-rich organs such as the liver, spleen and lymph nodes. Dual-energy subtraction techniques increased the signal difference-to-noise ratio of the particles by as much as a factor of 15.2 compared to the single-energy images. These nanoparticles produced no adverse effects in mice. Silver nanoparticles are an effective contrast agent for dual-energy x-ray imaging. With further design improvements, silver nanoparticles may prove valuable in breast cancer screening and diagnosis. • Silver has potential as a contrast agent for DE mammography. • Silica-coated silver nanoparticles are biocompatible and suited for in vivo use. • Silver nanoparticles produce strong contrast in vivo using DE mammography imaging systems.

  15. Dual PET and Near-Infrared Fluorescence Imaging Probes as Tools for Imaging in Oncology

    PubMed Central

    An, Fei-Fei; Chan, Mark; Kommidi, Harikrishna; Ting, Richard

    2016-01-01

    OBJECTIVE The purpose of this article is to summarize advances in PET fluorescence resolution, agent design, and preclinical imaging that make a growing case for clinical PET fluorescence imaging. CONCLUSION Existing SPECT, PET, fluorescence, and MRI contrast imaging techniques are already deeply integrated into the management of cancer, from initial diagnosis to the observation and management of metastases. Combined positron-emitting fluorescent contrast agents can convey new or substantial benefits that improve on these proven clinical contrast agents. PMID:27223168

  16. Glomerular filtration rate in evaluation of the effect of iodinated contrast media on renal function.

    PubMed

    Becker, Joshua; Babb, James; Serrano, Manuel

    2013-04-01

    The purpose of this study was to use measured glomerular filtration rate (GFR), the reference standard of renal function, to assess the deleterious effect of iodinated contrast media on renal function. Such an effect has been traditionally defined as a greater than 0.5-mg/dL increase in serum creatinine concentration or a 25% or greater increase 24-72 hours after the injection of iodinated contrast medium. This pilot investigation was focused on the consequences of clinically indicated IV injection of iodinated contrast media; intraarterial injection was excluded. One hundred thirteen patients with normal serum creatinine concentrations were enrolled in an approved protocol. At random, as chosen by one of the investigators, patients underwent imaging with one of three monomeric agents (iopamidol 300, iopromide 300, iohexol 300) and one dimeric agent (iodixanol 320). Measured GFR was determined immediately before CT and approximately 3 and 72 hours after the contrast injection for the CT examination. Iodinated contrast medium, a glomerular filtrate with no tubular excretion or reabsorption, was the GFR marker. Measured GFR was determined by x-ray fluorescence analysis with nonisotopic iodinated contrast media. Monomeric and dimeric contrast agents in diagnostic CT volumes (based on bodyweight and imaging protocol) did not induce a significant change in measured GFR (95% confidence by Wilcoxon test), suggesting that use of the evaluated contrast media will not lead to more than a 12% variation. The three monomeric agents studied and the one dimeric agent were equivalent in terms of lack of a significant effect on measured GFR when administered to patients with a normal GFR.

  17. VAS: A Vision Advisor System combining agents and object-oriented databases

    NASA Technical Reports Server (NTRS)

    Eilbert, James L.; Lim, William; Mendelsohn, Jay; Braun, Ron; Yearwood, Michael

    1994-01-01

    A model-based approach to identifying and finding the orientation of non-overlapping parts on a tray has been developed. The part models contain both exact and fuzzy descriptions of part features, and are stored in an object-oriented database. Full identification of the parts involves several interacting tasks each of which is handled by a distinct agent. Using fuzzy information stored in the model allowed part features that were essentially at the noise level to be extracted and used for identification. This was done by focusing attention on the portion of the part where the feature must be found if the current hypothesis of the part ID is correct. In going from one set of parts to another the only thing that needs to be changed is the database of part models. This work is part of an effort in developing a Vision Advisor System (VAS) that combines agents and objected-oriented databases.

  18. Noninvasive visualization of in vivo release and intratumoral distribution of surrogate MR contrast agent using the dual MR contrast technique.

    PubMed

    Onuki, Yoshinori; Jacobs, Igor; Artemov, Dmitri; Kato, Yoshinori

    2010-09-01

    A direct evaluation of the in vivo release profile of drugs from carriers is a clinical demand in drug delivery systems, because drug release characterized in vitro correlates poorly with in vivo release. The purpose of this study is to demonstrate the in vivo applicability of the dual MR contrast technique as a useful tool for noninvasive monitoring of the stability and the release profile of drug carriers, by visualizing in vivo release of the encapsulated surrogate MR contrast agent from carriers and its subsequent intratumoral distribution profile. The important aspect of this technique is that it incorporates both positive and negative contrast agents within a single carrier. GdDTPA, superparamagnetic iron oxide nanoparticles, and 5-fluorouracil were encapsulated in nano- and microspheres composed of poly(D,L-lactide-co-glycolide), which was used as a model carrier. In vivo studies were performed with orthotopic xenograft of human breast cancer. The MR-based technique demonstrated here has enabled visualization of the delivery of carriers, and release and intratumoral distribution of the encapsulated positive contrast agent. This study demonstrated proof-of-principle results for the noninvasive monitoring of in vivo release and distribution profiles of MR contrast agents, and thus, this technique will make a great contribution to the field. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  19. A Magnetic Chameleon: Biocompatible Lanthanide Fluoride Nanoparticles with Magnetic Field Dependent Tunable Contrast Properties as a Versatile Contrast Agent for Low to Ultrahigh Field MRI and Optical Imaging in Biological Window.

    PubMed

    Biju, Silvanose; Gallo, Juan; Bañobre-López, M; Manshian, Bella B; Soenen, Stefaan J; Himmelreich, Uwe; Vander Elst, Luce; Parac-Vogt, Tatjana N

    2018-05-23

    A novel type of multimodal, magnetic resonance imaging/optical imaging (MRI/OI) contrast agent was developed, based on core-shell lanthanide fluoride nanoparticles composed of a β-NaHoF4 core plus a β-NaGdF4:Yb 3+ , Tm 3+ shell with an average size of ∼24 nm. The biocompatibility of the particles was ensured by a surface modification with poly acrylic acid (PAA) and further functionalization with an affinity ligand, folic acid (FA). When excited using 980 nm near infrared (NIR) radiation, the contrast agent (CA) shows intense emission at 802 nm with lifetime of 791±3 μs, due to the transition 3 H 4 → 3 H 6 of Tm 3+ . Proton nuclear magnetic relaxation dispersion ( 1 H-NMRD) studies and magnetic resonance (MR) phantom imaging showed that the newly synthesized nanoparticles, decorated with poly(acrylic acid) and folic acid on the surface (NP-PAA-FA), can act mainly as a T 1 -weighted contrast agent below 1.5 T, a T 1 /T 2 dual-weighted contrast agent at 3 T, and as highly efficient T 2 -weighted contrast agent at ultrahigh fields. In addition, NP-PAA-FA showed very low cytotoxicity and no detectable cellular damage up to a dose of 500 μg mL -1 . © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Antibiofouling polymer-coated gold nanoparticles as a contrast agent for in vivo X-ray computed tomography imaging.

    PubMed

    Kim, Dongkyu; Park, Sangjin; Lee, Jae Hyuk; Jeong, Yong Yeon; Jon, Sangyong

    2007-06-20

    Current computed tomography (CT) contrast agents such as iodine-based compounds have several limitations, including short imaging times due to rapid renal clearance, renal toxicity, and vascular permeation. Here, we describe a new CT contrast agent based on gold nanoparticles (GNPs) that overcomes these limitations. Because gold has a higher atomic number and X-ray absorption coefficient than iodine, we expected that GNPs can be used as CT contrast agents. We prepared uniform GNPs ( approximately 30 nm in diameter) by general reduction of HAuCl4 by boiling with sodium citrate. The resulting GNPs were coated with polyethylene glycol (PEG) to impart antibiofouling properties, which extends their lifetime in the bloodstream. Measurement of the X-ray absorption coefficient in vitro revealed that the attenuation of PEG-coated GNPs is 5.7 times higher than that of the current iodine-based CT contrast agent, Ultravist. Furthermore, when injected intravenously into rats, the PEG-coated GNPs had a much longer blood circulation time (>4 h) than Ultravist (<10 min). Consequently, CT images of rats using PEG-coated GNPs showed a clear delineation of cardiac ventricles and great vessels. On the other hand, relatively high levels of GNPs accumulated in the spleen and liver, which contain phagocytic cells. Intravenous injection of PEG-coated GNPs into hepatoma-bearing rats resulted in a high contrast ( approximately 2-fold) between hepatoma and normal liver tissue on CT images. These results suggest that PEG-coated GNPs can be useful as a CT contrast agent for a blood pool and hepatoma imaging.

  1. Quality of abdominal computed tomography angiography: hand versus mechanical intravenous contrast administration in children.

    PubMed

    Ayyala, Rama S; Zurakowski, David; Lee, Edward Y

    2015-11-01

    Abdominal CT angiography has been increasingly used for evaluation of various conditions related to abdominal vasculature in the pediatric population. However, no direct comparison has evaluated the quality of abdominal CT angiography in children using hand versus mechanical administration of intravenous (IV) contrast agent. To compare hand versus mechanical administration of IV contrast agent in the quality of abdominal CT angiography in the pediatric population. We retrospectively reviewed the electronic medical record to identify pediatric patients (≤18 years) who had abdominal CT angiography between August 2012 and August 2013. The information obtained includes: (1) type of administration of IV contrast agent (hand [group 1] versus mechanical [group 2]), (2) size (gauge) of IV catheter, (3) amount of contrast agent administered and (4) rate of contrast agent administration (ml/s). Two reviewers independently performed qualitative and quantitative evaluation of abdominal CT angiography image quality. Qualitative evaluation of abdominal CT angiography image quality was performed by visual assessment of the degree of contrast enhancement in the region of interest (ROI) based on a 4-point scale. Quantitative evaluation of each CT angiography examination was performed by measuring the Hounsfield unit (HU) using an ROI within the abdominal aorta at two levels (celiac axis and the inferior mesenteric artery) for each child. Analysis of variance (ANOVA) using the F-test was applied to compare contrast enhancement within the abdominal aorta at two levels (celiac axis and inferior mesenteric artery) between hand administration and mechanical administration of IV contrast methods with adjustment for age. We identified 46 pediatric patients (24 male, 22 female; mean age 7.3 ± 5.5 years; range 5 weeks to 18 years) with abdominal CT angiography performed during the study period. Of these patients, 16 (35%; 1.7 ± 2.2 years; range 5 weeks to 5 years) had hand administration of IV contrast agent and 30 (65%; 10.2 ± 4.2 years; range 4-18 years) had mechanical administration of IV contrast agent. All 46 abdominal CT angiography studies were of diagnostic quality based on qualitative evaluation (all ≥3). All abdominal CT angiography studies from both groups showed diagnostic quality of contrast enhancement (>150 HU) at both the celiac axis and the inferior mesenteric artery (IMA) levels. The contrast enhancement of the abdominal aorta was not significantly different between the IV contrast administration methods at either the celiac axis level (360 ± 158 vs. 353 ± 116, P = 0.24) or the IMA level (340 ± 140 vs. 351 ± 90, P = 0.27), adjusting for age. Diagnostic-quality abdominal CT angiography can be achieved using hand administration of IV contrast agent in infants and young children (≤5 years).

  2. Prospective randomized trial of iohexol 350 versus meglumine sodium diatrizoate as an oral contrast agent for abdominopelvic computed tomography.

    PubMed

    Peterson, Christine M; Lin, Michael; Pilgram, Thomas; Heiken, Jay P

    2011-01-01

    To compare the efficacy and patient tolerance of iohexol and meglumine sodium diatrizoate as oral contrast agents for computed tomography (CT). One hundred patients were randomly assigned to drink 1000 mL of either meglumine sodium diatrizoate or iohexol 350 before their abdominopelvic CT examination. The images were evaluated independently and in a blinded fashion by 2 radiologists who scored the extent and density of bowel opacification. Attenuation value measurements were obtained in representative areas of each gastrointestinal tract segment (stomach, duodenum, jejunum, ileum, and colon) by a research technologist. Patients' tolerance of the oral contrast agent was assessed through a questionnaire administered immediately after the CT and with a follow-up phone call 2 to 3 days later. For most of the bowel, there was no statistically significant difference in the extent or degree of opacification between the 2 contrast agents. Opacification of the ileum was better with iohexol. There was no statistically significant difference between the 2 agents in adverse effects. Patients had a small but statistically significant preference for the taste of iohexol. Iohexol 350 is a satisfactory oral contrast agent for abdominopelvic CT. It opacifies the gastrointestinal tract as well as meglumine sodium diatrizoate does, and patients prefer the taste of iohexol to that of diatrizoate.

  3. An exploratory study of contrast agents for soft tissue visualization by means of high resolution X-ray computed tomography imaging.

    PubMed

    Pauwels, E; Van Loo, D; Cornillie, P; Brabant, L; Van Hoorebeke, L

    2013-04-01

    High resolution X-ray computed tomography (CT), or microCT, is a promising and already widely used technique in various scientific fields. Also for histological purposes it has great potential. Although microCT has proven to be a valuable technique for the imaging of bone structures, the visualization of soft tissue structures is still an important challenge due to their low inherent X-ray contrast. One way to achieve contrast enhancement is to make use of contrast agents. However, contrary to light and electron microscopy, knowledge about contrast agents and staining procedures is limited for X-ray CT. The purpose of this paper is to identify useful X-ray contrast agents for soft tissue visualization, which can be applied in a simple way and are also suited for samples larger than (1 cm)(3) . And 28 chemical substances have been investigated. All chemicals were applied in the form of concentrated aqueous solutions in which the samples were immersed. First, strips of green Bacon were stained to evaluate contrast enhancement between muscle and adipose tissue. Furthermore it was also tested whether the contrast agents remained fixed in the tissue after staining by re-immersing them in water. Based on the results, 12 contrast agents were selected for further testing on postmortem mice hind legs, containing a variety of different tissues, including muscle, fat, bone, cartilage and tendons. It was evaluated whether the contrast agents allowed a clearer distinction between the different soft tissue structures present. Finally also penetration depth was measured. And 26 chemicals resulted in contrast enhancement between muscle and adipose tissue in the Bacon strips. Mercury(II)chloride (HgCl2 ), phosphotungstic acid (PTA), phosphomolybdic acid (PMA) and ammonium orthomolybdate ((NH4 )2 MoO4 ) remained fixed after re-immersion in water. The penetration tests showed that potassium iodide (KI) and sodium tungstate can be most efficiently used for large samples of the order of several tens of cm(3) . PMA, PTA, HgCl2 and also to a lesser extent Na2 WO4 and (NH4 )2 MoO4 allowed a clearer distinction between the different soft tissue structures present. © 2013 The Authors Journal of Microscopy © 2013 Royal Microscopical Society.

  4. Improved sensitivity of computed tomography towards iodine and gold nanoparticle contrast agents via iterative reconstruction methods

    PubMed Central

    Bernstein, Ally Leigh; Dhanantwari, Amar; Jurcova, Martina; Cheheltani, Rabee; Naha, Pratap Chandra; Ivanc, Thomas; Shefer, Efrat; Cormode, David Peter

    2016-01-01

    Computed tomography is a widely used medical imaging technique that has high spatial and temporal resolution. Its weakness is its low sensitivity towards contrast media. Iterative reconstruction techniques (ITER) have recently become available, which provide reduced image noise compared with traditional filtered back-projection methods (FBP), which may allow the sensitivity of CT to be improved, however this effect has not been studied in detail. We scanned phantoms containing either an iodine contrast agent or gold nanoparticles. We used a range of tube voltages and currents. We performed reconstruction with FBP, ITER and a novel, iterative, modal-based reconstruction (IMR) algorithm. We found that noise decreased in an algorithm dependent manner (FBP > ITER > IMR) for every scan and that no differences were observed in attenuation rates of the agents. The contrast to noise ratio (CNR) of iodine was highest at 80 kV, whilst the CNR for gold was highest at 140 kV. The CNR of IMR images was almost tenfold higher than that of FBP images. Similar trends were found in dual energy images formed using these algorithms. In conclusion, IMR-based reconstruction techniques will allow contrast agents to be detected with greater sensitivity, and may allow lower contrast agent doses to be used. PMID:27185492

  5. Peripheral Artery Disease

    MedlinePlus

    ... This minimally invasive imaging exam relies on a contrast agent and x-rays to show blood flow in ... pinpoint any blockages that may be present. The contrast agent is injected through a tube or catheter that ...

  6. T1-T2 dual-modal MRI of brain gliomas using PEGylated Gd-doped iron oxide nanoparticles.

    PubMed

    Xiao, Ning; Gu, Wei; Wang, Hao; Deng, Yunlong; Shi, Xin; Ye, Ling

    2014-03-01

    To overcome the negative contrast limitations of iron oxide-based contrast agents and to improve the biocompatibility of Gd-chelate contrast agents, PEGylated Gd-doped iron oxide (PEG-GdIO) NPs as a T1-T2 dual-modal contrast agent were synthesized by the polyol method. The transverse relaxivity (r2) and longitudinal relaxivity (r1) of PEG-GdIO were determined to be 66.9 and 65.9 mM(-1) s(-1), respectively. The high r1 value and low r2/r1 ratio make PEG-GdIO NPs suitable as a T1-T2 dual-modal contrast agent. The in vivo MRI demonstrated a brighter contrast enhancement in T1-weighted image and a simultaneous darken effect in T2-weighted MR image compared to the pre-contrast image in the region of glioma. Furthermore, the biocompatibility of PEG-GdIO NPs was confirmed by the in vitro MTT cytotoxicity and in vivo histological analyses (H&E). Therefore, PEG-GdIO NPs hold great potential in T1-T2 dual-modal imaging for the diagnosis of brain glioma. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. Mouse blood vessel imaging by in-line x-ray phase-contrast imaging

    NASA Astrophysics Data System (ADS)

    Zhang, Xi; Liu, Xiao-Song; Yang, Xin-Rong; Chen, Shao-Liang; Zhu, Pei-Ping; Yuan, Qing-Xi

    2008-10-01

    It is virtually impossible to observe blood vessels by conventional x-ray imaging techniques without using contrast agents. In addition, such x-ray systems are typically incapable of detecting vessels with diameters less than 200 µm. Here we show that vessels as small as 30 µm could be detected using in-line phase-contrast x-ray imaging without the use of contrast agents. Image quality was greatly improved by replacing resident blood with physiological saline. Furthermore, an entire branch of the portal vein from the main axial portal vein to the eighth generation of branching could be captured in a single phase-contrast image. Prior to our work, detection of 30 µm diameter blood vessels could only be achieved using x-ray interferometry, which requires sophisticated x-ray optics. Our results thus demonstrate that in-line phase-contrast x-ray imaging, using physiological saline as a contrast agent, provides an alternative to the interferometric method that can be much more easily implemented and also offers the advantage of a larger field of view. A possible application of this methodology is in animal tumor models, where it can be used to observe tumor angiogenesis and the treatment effects of antineoplastic agents.

  8. Quantum dots targeted to vascular endothelial growth factor receptor 2 as a contrast agent for the detection of colorectal cancer

    NASA Astrophysics Data System (ADS)

    Carbary-Ganz, Jordan L.; Barton, Jennifer K.; Utzinger, Urs

    2014-08-01

    We successfully labeled colorectal cancer in vivo using quantum dots targeted to vascular endothelial growth factor receptor 2 (VEGFR2). Quantum dots with emission centered at 655 nm were bioconjugated to anti-VEGFR2 antibodies through streptavidin/biotin linking. The resulting QD655-VEGFR2 contrast agent was applied in vivo to the colon of azoxymethane (AOM) treated mice via lavage and allowed to incubate. The colons were then excised, cut longitudinally, opened to expose the lumen, and imaged en face using a fluorescence stereoscope. The QD655-VEGFR2 contrast agent produced a significant increase in contrast between diseased and undiseased tissues, allowing for fluorescence-based visualization of the diseased areas of the colon. Specificity was assessed by observing insignificant contrast increase when labeling colons of AOM-treated mice with quantum dots bioconjugated to isotype control antibodies, and by labeling the colons of saline-treated control mice. This contrast agent has a great potential for in vivo imaging of the colon through endoscopy.

  9. NOTE: The effects of paramagnetic contrast agents on metabolite protons in aqueous solution

    NASA Astrophysics Data System (ADS)

    Murphy, Philip S.; Leach, Martin O.; Rowland, Ian J.

    2002-03-01

    The longitudinal (R1) and transverse (R2) relaxivities of the clinically used contrast agents Gd(DTPA)2-, Gd(DOTA)- and Gd(DTPA-BMA) have been determined in mixed aqueous metabolite solutions for choline, creatine and N-acetylaspartate. Measurements were performed at 1.5 T using a STEAM sequence on 25 mM metabolite solutions at pH = 7.4 and 22 °C. The data showed that for all the contrast agents and metabolites, R1 ~ R2. The largest range of relaxivity values was found for Gd(DTPA)2-, where R2 = 6.8 +/- 0.3 mM-1 s-1 for choline and 1.5 +/- 0.4 mM-1 s-1 for N-acetylaspartate. Variation in relaxivity values was attributed primarily to differences between the charges of the paramagnetic agent and metabolite. The maximum potential influence of the contrast agents on in vivo metabolite signals was calculated using the measured relaxivities.

  10. Dual-Frequency Piezoelectric Transducers for Contrast Enhanced Ultrasound Imaging

    PubMed Central

    Martin, K. Heath; Lindsey, Brooks D.; Ma, Jianguo; Lee, Mike; Li, Sibo; Foster, F. Stuart; Jiang, Xiaoning; Dayton, Paul A.

    2014-01-01

    For many years, ultrasound has provided clinicians with an affordable and effective imaging tool for applications ranging from cardiology to obstetrics. Development of microbubble contrast agents over the past several decades has enabled ultrasound to distinguish between blood flow and surrounding tissue. Current clinical practices using microbubble contrast agents rely heavily on user training to evaluate degree of localized perfusion. Advances in separating the signals produced from contrast agents versus surrounding tissue backscatter provide unique opportunities for specialized sensors designed to image microbubbles with higher signal to noise and resolution than previously possible. In this review article, we describe the background principles and recent developments of ultrasound transducer technology for receiving signals produced by contrast agents while rejecting signals arising from soft tissue. This approach relies on transmitting at a low-frequency and receiving microbubble harmonic signals at frequencies many times higher than the transmitted frequency. Design and fabrication of dual-frequency transducers and the extension of recent developments in transducer technology for dual-frequency harmonic imaging are discussed. PMID:25375755

  11. Gold nanoparticles as a contrast agent for in vivo tumor imaging with photoacoustic tomography

    NASA Astrophysics Data System (ADS)

    Zhang, Q.; Iwakuma, N.; Sharma, P.; Moudgil, B. M.; Wu, C.; McNeill, J.; Jiang, H.; Grobmyer, S. R.

    2009-09-01

    Photoacoustic tomography (PAT) is a rapidly emerging non-invasive imaging technology that integrates the merits of high optical contrast with high ultrasound resolution. The ability to quantitatively and non-invasively image nanoparticles has important implications for the development of nanoparticles as in vivo cancer diagnostic and therapeutic agents. In this study, the ability of systemically administered poly(ethylene glycol)-coated (PEGylated) gold nanoparticles as a contrast agent for in vivo tumor imaging with PAT has been evaluated. We demonstrate that gold nanoparticles (20 and 50 nm) have high photoacoustic contrast as compared to mouse tissue ex vivo. Gold nanoparticles can be visualized in mice in vivo following subcutaneous administration using PAT. Following intravenous administration of PEGylated gold nanoparticles to tumor-bearing mice, accumulation of gold nanoparticles in tumors can be effectively imaged with PAT. With gold nanoparticles as a contrast agent, PAT has important potential applications in the image guided therapy of superficial tumors such as breast cancer, melanoma and Merkel cell carcinoma.

  12. Dual-frequency piezoelectric transducers for contrast enhanced ultrasound imaging.

    PubMed

    Martin, K Heath; Lindsey, Brooks D; Ma, Jianguo; Lee, Mike; Li, Sibo; Foster, F Stuart; Jiang, Xiaoning; Dayton, Paul A

    2014-11-04

    For many years, ultrasound has provided clinicians with an affordable and effective imaging tool for applications ranging from cardiology to obstetrics. Development of microbubble contrast agents over the past several decades has enabled ultrasound to distinguish between blood flow and surrounding tissue. Current clinical practices using microbubble contrast agents rely heavily on user training to evaluate degree of localized perfusion. Advances in separating the signals produced from contrast agents versus surrounding tissue backscatter provide unique opportunities for specialized sensors designed to image microbubbles with higher signal to noise and resolution than previously possible. In this review article, we describe the background principles and recent developments of ultrasound transducer technology for receiving signals produced by contrast agents while rejecting signals arising from soft tissue. This approach relies on transmitting at a low-frequency and receiving microbubble harmonic signals at frequencies many times higher than the transmitted frequency. Design and fabrication of dual-frequency transducers and the extension of recent developments in transducer technology for dual-frequency harmonic imaging are discussed.

  13. Encapsulated microbubbles and echogenic liposomes for contrast ultrasound imaging and targeted drug delivery

    PubMed Central

    Paul, Shirshendu; Nahire, Rahul; Mallik, Sanku; Sarkar, Kausik

    2014-01-01

    Micron- to nanometer-sized ultrasound agents, like encapsulated microbubbles and echogenic liposomes, are being developed for diagnostic imaging and ultrasound mediated drug/gene delivery. This review provides an overview of the current state of the art of the mathematical models of the acoustic behavior of ultrasound contrast microbubbles. We also present a review of the in vitro experimental characterization of the acoustic properties of microbubble based contrast agents undertaken in our laboratory. The hierarchical two-pronged approach of modeling contrast agents we developed is demonstrated for a lipid coated (Sonazoid™) and a polymer shelled (poly D-L-lactic acid) contrast microbubbles. The acoustic and drug release properties of the newly developed echogenic liposomes are discussed for their use as simultaneous imaging and drug/gene delivery agents. Although echogenicity is conclusively demonstrated in experiments, its physical mechanisms remain uncertain. Addressing questions raised here will accelerate further development and eventual clinical approval of these novel technologies. PMID:26097272

  14. Development of PEGylated KMnF3 nanoparticles as a T1-weighted contrast agent: chemical synthesis, in vivo brain MR imaging, and accounting for high relaxivity

    NASA Astrophysics Data System (ADS)

    Liu, Zhi-Jun; Song, Xiao-Xia; Tang, Qun

    2013-05-01

    Magnetic nanoparticles consisting of manganese-based T1-weighted contrast agents have rapidly achieved clinical application, however low proton relaxivity impedes further development. In this report, by analyzing nanoparticles' surface oxidation states we propose the possible reason for the low r1 relaxivity of common MnO nanoparticles and develop PEGylated fluoroperovskite KMnF3 nanoparticles as new T1-weighted contrast agents, which exhibit the highest longitudinal relaxivity (r1 = 23.15 mM-1 s-1) among all the reported manganese-based T1-weighted contrast agents. We, for the first time, illustrate a typical example showing that the surface oxidation states of metal ions exposed on the nanoparticles' surfaces are able to influence not only the optical, magnetic, electronic or catalytic properties but also water proton longitudinal relaxivity when applied as an MRI contrast agent. Cytotoxicity tests demonstrate that the PEGylated KMnF3 nanoparticles are free from toxicity. Further in vivo MRI experiments distinctively depict fine anatomical features in brain imaging at a low dose of 5 mg of Mn per kg and possible removal from the kidneys due to their small size and biocompatibility.Magnetic nanoparticles consisting of manganese-based T1-weighted contrast agents have rapidly achieved clinical application, however low proton relaxivity impedes further development. In this report, by analyzing nanoparticles' surface oxidation states we propose the possible reason for the low r1 relaxivity of common MnO nanoparticles and develop PEGylated fluoroperovskite KMnF3 nanoparticles as new T1-weighted contrast agents, which exhibit the highest longitudinal relaxivity (r1 = 23.15 mM-1 s-1) among all the reported manganese-based T1-weighted contrast agents. We, for the first time, illustrate a typical example showing that the surface oxidation states of metal ions exposed on the nanoparticles' surfaces are able to influence not only the optical, magnetic, electronic or catalytic properties but also water proton longitudinal relaxivity when applied as an MRI contrast agent. Cytotoxicity tests demonstrate that the PEGylated KMnF3 nanoparticles are free from toxicity. Further in vivo MRI experiments distinctively depict fine anatomical features in brain imaging at a low dose of 5 mg of Mn per kg and possible removal from the kidneys due to their small size and biocompatibility. Electronic supplementary information (ESI) available: Experimental procedure for two types of MnO nanoparticles, T1-weighted mapping. See DOI: 10.1039/c3nr00721a

  15. Contrast-enhanced digital mammography (CEDM): imaging modeling, computer simulations, and phantom study

    NASA Astrophysics Data System (ADS)

    Chen, Biao; Jing, Zhenxue; Smith, Andrew

    2005-04-01

    Contrast enhanced digital mammography (CEDM), which is based upon the analysis of a series of x-ray projection images acquired before/after the administration of contrast agents, may provide physicians critical physiologic and morphologic information of breast lesions to determine the malignancy of lesions. This paper proposes to combine the kinetic analysis (KA) of contrast agent uptake/washout process and the dual-energy (DE) contrast enhancement together to formulate a hybrid contrast enhanced breast-imaging framework. The quantitative characteristics of materials and imaging components in the x-ray imaging chain, including x-ray tube (tungsten) spectrum, filter, breast tissues/lesions, contrast agents (non-ionized iodine solution), and selenium detector, were systematically modeled. The contrast-noise-ration (CNR) of iodinated lesions and mean absorbed glandular dose were estimated mathematically. The x-ray techniques optimization was conducted through a series of computer simulations to find the optimal tube voltage, filter thickness, and exposure levels for various breast thicknesses, breast density, and detectable contrast agent concentration levels in terms of detection efficiency (CNR2/dose). A phantom study was performed on a modified Selenia full field digital mammography system to verify the simulated results. The dose level was comparable to the dose in diagnostic mode (less than 4 mGy for an average 4.2 cm compressed breast). The results from the computer simulations and phantom study are being used to optimize an ongoing clinical study.

  16. 7 CFR 400.405 - Agent and loss adjuster responsibilities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... establishing a database for the purposes of: (1) Identifying agents and loss adjusters on an individual basis; (2) Evaluating agents and loss adjusters to determine level of performance; (3) Determining...

  17. Development of PEGylated KMnF3 nanoparticles as a T1-weighted contrast agent: chemical synthesis, in vivo brain MR imaging, and accounting for high relaxivity.

    PubMed

    Liu, Zhi-jun; Song, Xiao-xia; Tang, Qun

    2013-06-07

    Magnetic nanoparticles consisting of manganese-based T1-weighted contrast agents have rapidly achieved clinical application, however low proton relaxivity impedes further development. In this report, by analyzing nanoparticles' surface oxidation states we propose the possible reason for the low r1 relaxivity of common MnO nanoparticles and develop PEGylated fluoroperovskite KMnF3 nanoparticles as new T1-weighted contrast agents, which exhibit the highest longitudinal relaxivity (r1 = 23.15 mM(-1) s(-1)) among all the reported manganese-based T1-weighted contrast agents. We, for the first time, illustrate a typical example showing that the surface oxidation states of metal ions exposed on the nanoparticles' surfaces are able to influence not only the optical, magnetic, electronic or catalytic properties but also water proton longitudinal relaxivity when applied as an MRI contrast agent. Cytotoxicity tests demonstrate that the PEGylated KMnF3 nanoparticles are free from toxicity. Further in vivo MRI experiments distinctively depict fine anatomical features in brain imaging at a low dose of 5 mg of Mn per kg and possible removal from the kidneys due to their small size and biocompatibility.

  18. In vivo small animal micro-CT using nanoparticle contrast agents

    PubMed Central

    Ashton, Jeffrey R.; West, Jennifer L.; Badea, Cristian T.

    2015-01-01

    Computed tomography (CT) is one of the most valuable modalities for in vivo imaging because it is fast, high-resolution, cost-effective, and non-invasive. Moreover, CT is heavily used not only in the clinic (for both diagnostics and treatment planning) but also in preclinical research as micro-CT. Although CT is inherently effective for lung and bone imaging, soft tissue imaging requires the use of contrast agents. For small animal micro-CT, nanoparticle contrast agents are used in order to avoid rapid renal clearance. A variety of nanoparticles have been used for micro-CT imaging, but the majority of research has focused on the use of iodine-containing nanoparticles and gold nanoparticles. Both nanoparticle types can act as highly effective blood pool contrast agents or can be targeted using a wide variety of targeting mechanisms. CT imaging can be further enhanced by adding spectral capabilities to separate multiple co-injected nanoparticles in vivo. Spectral CT, using both energy-integrating and energy-resolving detectors, has been used with multiple contrast agents to enable functional and molecular imaging. This review focuses on new developments for in vivo small animal micro-CT using novel nanoparticle probes applied in preclinical research. PMID:26581654

  19. Ni-Fe2O4 nanoparticles as contrast agents for magnetic resonance imaging.

    PubMed

    Ahmad, Tanveer; Rhee, Ilsu; Hong, Sungwook; Chang, Yongmin; Lee, Jaejun

    2011-07-01

    Reported herein is the synthesis of a dextran coating on nickel ferrite (Ni-Fe2O4) nanoparticles via chemical coprecipitation. The aqueous solution of the synthesized nanoparticles showed good colloidal stability, and no precipitate was observed 20 months after the synthesis. The coated nanoparticles were found to be cylindrical in shape in the TEM images, and showed a uniform size distribution with an average length and diameter of 17 and 4 nm, respectively. The coated particles were evaluated as potential T1 and T2 contrast agents for MRI. The T1 and T2 relaxations of the hydrogen protons in the water molecules in an aqueous solution of dextran-coated Ni-Fe2O4 nanoparticles were studied. It was found that the T1 relaxivity for the aqueous solution of dextran-coated nanoparticles was slightly greater than that of a commercial Gd-DTPA-BMA contrast agent. The T2 relaxivity, however, was almost twice that of the commercial Gd-DTPA-BMA contrast agent. Animal experimentation also demonstrated that the dextran-coated Ni-Fe2O4 nanoparticles are suitable for use as either T1 or T2 contrast agents in MRI.

  20. Quantitation of MRI sensitivity to quasi-monodisperse microbubble contrast agents for spatially resolved manometry.

    PubMed

    Bencsik, Martin; Al-Rwaili, Amgad; Morris, Robert; Fairhurst, David J; Mundell, Victoria; Cave, Gareth; McKendry, Jonathan; Evans, Stephen

    2013-11-01

    The direct in-vivo measurement of fluid pressure cannot be achieved with MRI unless it is done with the contribution of a contrast agent. No such contrast agents are currently available commercially, whilst those demonstrated previously only produced qualitative results due to their broad size distribution. Our aim is to quantitate then model the MR sensitivity to the presence of quasi-monodisperse microbubble populations. Lipid stabilised microbubble populations with mean radius 1.2 ± 0.8 μm have been produced by mechanical agitation. Contrast agents with increasing volume fraction of bubbles up to 4% were formed and the contribution the bubbles bring to the relaxation rate was quantitated. A periodic pressure change was also continuously applied to the same contrast agent, until MR signal changes were only due to bubble radius change and not due to a change in bubble density. The MR data compared favourably with the prediction of an improved numerical simulation. An excellent MR sensitivity of 23 % bar(-1) has been demonstrated. This work opens up the possibility of generating microbubble preparations tailored to specific applications with optimised MR sensitivity, in particular MRI based in-vivo manometry. Copyright © 2012 Wiley Periodicals, Inc.

  1. Design of a novel class of protein-based magnetic resonance imaging contrast agents for the molecular imaging of cancer biomarkers

    PubMed Central

    Xue, Shenghui; Qiao, Jingjuan; Pu, Fan; Cameron, Mathew; Yang, Jenny J.

    2014-01-01

    Magnetic resonance imaging (MRI) of disease biomarkers, especially cancer biomarkers, could potentially improve our understanding of the disease and drug activity during preclinical and clinical drug treatment and patient stratification. MRI contrast agents with high relaxivity and targeting capability to tumor biomarkers are highly required. Extensive work has been done to develop MRI contrast agents. However, only a few limited literatures report that protein residues can function as ligands to bind Gd3+ with high binding affinity, selectivity, and relaxivity. In this paper, we focus on reporting our current progress on designing a novel class of protein-based Gd3+ MRI contrast agents (ProCAs) equipped with several desirable capabilities for in vivo application of MRI of tumor biomarkers. We will first discuss our strategy for improving the relaxivity by a novel protein-based design. We then discuss the effect of increased relaxivity of ProCAs on improving the detection limits for MRI contrast agent, especially for in vivo application. We will further report our efforts to improve in vivo imaging capability and our achievement in molecular imaging of cancer biomarkers with potential preclinical and clinical applications. PMID:23335551

  2. Sonophoresis Using Ultrasound Contrast Agents: Dependence on Concentration.

    PubMed

    Park, Donghee; Song, Gillsoo; Jo, Yongjun; Won, Jongho; Son, Taeyoon; Cha, Ohrum; Kim, Jinho; Jung, Byungjo; Park, Hyunjin; Kim, Chul-Woo; Seo, Jongbum

    2016-01-01

    Sonophoresis can increase skin permeability to various drugs in transdermal drug delivery. Cavitation is recognized as the predominant mechanism of sonophoresis. Recently, a new logical approach to enhance the efficiency of transdermal drug delivery was tried. It is to utilize the engineered microbubble and its resonant frequency for increase of cavitation activity. Actively-induced cavitation with low-intensity ultrasound (less than ~1 MPa) causes disordering of the lipid bilayers and the formation of aqueous channels by stable cavitation which indicates a continuous oscillation of bubbles. Furthermore, the mutual interactions of microbubble determined by concentration of added bubble are also thought to be an important factor for activity of stable cavitation, even in different characteristics of drug. In the present study, we addressed the dependence of ultrasound contrast agent concentration using two types of drug on the efficiency of transdermal drug delivery. Two types of experiment were designed to quantitatively evaluate the efficiency of transdermal drug delivery according to ultrasound contrast agent concentration. First, an experiment of optical clearing using a tissue optical clearing agent was designed to assess the efficiency of sonophoresis with ultrasound contrast agents. Second, a Franz diffusion cell with ferulic acid was used to quantitatively determine the amount of drug delivered to the skin sample by sonophoresis with ultrasound contrast agents. The maximum enhancement ratio of sonophoresis with a concentration of 1:1,000 was approximately 3.1 times greater than that in the ultrasound group without ultrasound contrast agent and approximately 7.5 times greater than that in the control group. These results support our hypothesis that sonophoresis becomes more effective in transdermal drug delivery due to the presence of engineered bubbles, and that the efficiency of transdermal drug delivery using sonophoresis with microbubbles depends on the concentration of microbubbles in case stable cavitation is predominant.

  3. Macromolecular and Dendrimer Based Magnetic Resonance Contrast Agents

    PubMed Central

    Bumb, Ambika; Brechbiel, Martin W.; Choyke, Peter

    2010-01-01

    Magnetic resonance imaging (MRI) is a powerful imaging modality that can provide an assessment of function or molecular expression in tandem with anatomic detail. Over the last 20–25 years, a number of gadolinium based MR contrast agents have been developed to enhance signal by altering proton relaxation properties. This review explores a range of these agents from small molecule chelates, such as Gd-DTPA and Gd-DOTA, to macromolecular structures composed of albumin, polylysine, polysaccharides (dextran, inulin, starch), poly(ethylene glycol), copolymers of cystamine and cystine with GD-DTPA, and various dendritic structures based on polyamidoamine and polylysine (Gadomers). The synthesis, structure, biodistribution and targeting of dendrimer-based MR contrast agents are also discussed. PMID:20590365

  4. Multipixel frequency-domain imaging of spontaneous canine breast disease using fluorescent contrast agents

    NASA Astrophysics Data System (ADS)

    Reynolds, Jeffery S.; Thompson, Alan B.; Troy, Tamara L.; Mayer, Ralf H.; Waters, David J.; Sevick-Muraca, Eva M.

    1999-07-01

    In this paper we demonstrate the ability to detect the frequency-domain fluorescent signal from the contrast agent indocyanine green within the mammary chain of dogs with spontaneous mammary tumors. We use a gain-modulated image intensifier to rapidly capture multi-pixel images of the fluorescent modulation amplitude, modulation phase, and average intensity signals. Excitation is provided by a 100 MHz amplitude-modulated, 780 nm laser diode. Time series images of the uptake and clearance of the contrast agent in the diseased tissue are also presented.

  5. Characterization of novel molecular photoacoustic contrast agents for in vivo photoacoustic tomography

    NASA Astrophysics Data System (ADS)

    Laoui, Samir

    Photoacoustic tomography is a hybrid imaging modality that takes advantage of the high contrast of pure optical imaging and the high intrinsic resolution of ultrasound without the necessity of ionizing radiation. Photoacoustic imaging (PM) is neither purely optical nor purely acoustical in nature, but a combination of the two. It is fundamentally based on light excitation and ultrasonic detection. Photoacoustic imaging has been successful without the introduction of exogenous contrast agents; however, to image deeper regions of biological tissue, a contrast agent is necessary. Several types of photoacoustic contrast agents have been made available for diagnostic purposes; however, the majority of literature has focused on gold nanoparticle systems for which the surface-plasmon resonance effect is important. The only option currently available for molecular PM contrast agents is to choose an existing near infrared absorbing fluorescent probes with the hope that they may generate a substantial photoacoustic (PA) response. However, these dyes have been designed with an optimized fluorescence emission response and are not anticipated to generate an adequate photoacoustic response. This dissertation addresses this lack of precedence in the literature for understanding the mechanism of a photoacoustic signal generation from strongly absorbing dye molecules including BODIPY, cyanine and curcumin systems. This work represents preliminary efforts in bringing novel molecular photoacoustic contrast agents (MPACs) into the photoacoustic imaging arena. To this end, photoacoustic and optical Z-scan experiments, and quenching studies were employed to demonstrate correlation of photoacoustic emission enhancement with excited state absorption mechanisms. To investigate further the photoacoustic emission in a practical imaging setting, MPACs were imaged using a recently developed photoacoustic imaging tomography system which was constructed exclusively for the purpose of this study.

  6. Nanoparticle Based Contrast Enhancement for Discriminating Indolent From Aggressive Prostate Cancer

    DTIC Science & Technology

    2016-06-01

    contrast agent Major Task 1: Evaluate nanoparticle contrast in a saline model Milestones: Relationship between electrical properties and NP concentration...by Jan 2017 5 What was accomplished under these goals? 1) Major Activities ( Saline Model) – Our major focus of the 1st year of this program was to...develop an electrode array for saline tests and to begin evaluation of using nanoparticles as a contrast agent for electrical impedance measurements

  7. Relative diffusion of paramagnetic metal complexes of MRI contrast agents in an isotropic hydrogel medium.

    PubMed

    Weerakoon, Bimali Sanjeevani; Osuga, Toshiaki

    2017-03-01

    The observation of molecular diffusion by means of magnetic resonance imaging (MRI) is significant in the evaluation of the metabolic activity of living tissues. Series of MRI examinations were conducted on a diffusion model to study the behaviour of the diffusion process of different-molecular-weight (MW) paramagnetic MRI contrast agents in an isotropic agar hydrogel medium. The model consisted of a solidified 1 % agar gel with an initial concentration of 0.5 mmol/L contrast solution layered on top of the gel. The diffusion process was monitored at pre-determined time intervals of immediately, 1, 6, 9, 23, and 48 h after introduction of the contrast agents onto the agar gel with a T1-weighted spin-echo (SE) pulse sequence. Three types of paramagnetic contrast agents, Gd-DTPA with a MW of 547.57 g/mol, Prohance with a MW of 558.69 g/mol and MnCl 2 with a MW of 125.84 g/mol, resulted in an approximate average diffusional displacement ratio of 1:1:2 per hour, respectively, within 48 h of the experiment. Therefore, the results of this study supported the hypothesis that the rate of the diffusion process of MRI contrast agents in the agar hydrogel medium is inversely related to their MWs. However, more repetitions are necessary under various types of experimental conditions and also with various types of contrast media of different MWs for further confirmation and validation of these results.

  8. New oil-in-water magnetic emulsion as contrast agent for in vivo magnetic resonance imaging (MRI).

    PubMed

    Ahmed, Naveed; Jaafar-Maalej, Chiraz; Eissa, Mohamed Mahmoud; Fessi, Hatem; Elaissari, Abdelhamid

    2013-09-01

    Nowadays, bio-imaging techniques are widely applied for the diagnosis of various diseased/tumoral tissues in the body using different contrast agents. Accordingly, the advancement in bionanotechnology research is enhanced in this regard. Among contrast agents used, superparamagnetic iron oxide nanoparticles were developed by many researchers and applied for in vive magnetic resonance imaging (MRI). In this study, a new oil-in-water magnetic emulsion was used as contrast agent in MRI, after being characterized in terms of particle size, iron oxide content, magnetic properties and colloidal stability using dynamic light scattering (DLS), thermal gravimetric analysis (TGA), vibrating sample magnetometer (VSM) and zeta potential measurement techniques, respectively. The hydrodynamic size and magnetic content of the magnetic colloidal particles were found to be 250 nm and 75 wt%, respectively. In addition, the used magnetic emulsion possesses superparamagentic properties and high colloidal stability in aqueous medium. Then, the magnetic emulsion was highly diluted and administered intravenously to the Sprague dawley rats to be tested as contrast agent for in vivo MRI. In this preliminary study, MRI images showed significant enhancement in contrast, especially for T2 (relaxation time) contrast enhancement, indicating the distribution of magnetic colloidal nanoparticles within organs, like liver, spleen and kidneys of the Sprague dawley rats. In addition, it was found that 500 microL of the highly diluted magnetic emulsion (0.05 wt%) was found adequate for MRI analysis. This seems to be useful for further investigations especially in theranostic applications of magnetic emulsion.

  9. Acute side effects of three commonly used gadolinium contrast agents in the paediatric population.

    PubMed

    Neeley, Chris; Moritz, Michael; Brown, Jeffrey J; Zhou, Yihua

    2016-07-01

    To determine the incidence of acute side effects of three commonly used gadolinium contrast agents in the paediatric population. A retrospective review of medical records was performed to determine the incidence of acute adverse side effects of i.v. gadolinium contrast agents [MultiHance(®) (Bracco Diagnostics Inc., Princeton, NJ), Magnevist(®) (Bayer Healthcare Pharmaceuticals, Wayne, NJ) or Gadavist(®) (Bayer HealthCare Pharmaceuticals)] in paediatric patients. 40 of the 2393 patients who received gadolinium contrast agents experienced acute side effects, representing an incidence of 1.7%. The majority of the acute side effects (in 30 patients) were nausea and vomiting. The incidence was significantly higher in non-sedated patients (2.37% vs 0.7%; p = 0.0018). Furthermore, without sedation, the incidence of both nausea and vomiting was significantly higher in children receiving MultiHance, with a 4.48% incidence of nausea when compared with Magnevist (0.33%, p < 0.0001) and Gadavist (0.28%, p < 0.0001) and a 2.36% incidence of vomiting compared with those for Magnevist (0.50%, p = 0.0054) and Gadavist (0.28%, p = 0.014), whereas no difference was observed between Magnevist and Gadavist within the power of the study. In addition, there was no apparent difference between any of the three contrast agents for the incidence of allergy or other acute side effects detected, given the sample size. The gadolinium contrast agents MultiHance, Magnevist and Gadavist have a low incidence of acute side effects in the paediatric population, a rate that is further reduced in moderately sedated patients. MultiHance demonstrated significantly increased incidence of gastrointestinal symptoms compared with Magnevist and Gadavist. The incidence of acute side effects of three commonly used gadolinium contrast agents was determined in the paediatric population, which can have clinical implications.

  10. Differential effects of two MRI contrast agents on the integrity and distribution of rAAV2 and rAAV5 in the rat striatum

    PubMed Central

    Osting, Sue; Bennett, Antonette; Power, Shelby; Wackett, Jordan; Hurley, Samuel A; Alexander, Andrew L; Agbandje-Mckena, Mavis; Burger, Corinna

    2014-01-01

    Intraoperative magnetic resonance imaging (MRI) has been proposed as a method to optimize intracerebral targeting and for tracking infusate distribution in gene therapy trials for nervous system disorders. We thus investigated possible effects of two MRI contrast agents, gadoteridol (Gd) and galbumin (Gab), on the distribution and levels of transgene expression in the rat striatum and their effect on integrity and stability of recombinant adeno-associated virus (rAAV) particles. MRI studies showed that contrast agent distribution did not predict rAAV distribution. However, green fluorescent protein (GFP) immunoreactivity revealed an increase in distribution of rAAV5-GFP, but not rAAV2-GFP, in the presence of Gd when compared with viral vector injected alone. In contrast, Gab increased the distribution of rAAV2-GFP not rAAV5-GFP. These observations pointed to a direct effect of infused contrast agent on the rAAV particles. Negative-stain electron microscopy (EM), DNAase treatment, and differential scanning calorimetry (DSC) were used to monitor rAAV2 and rAAV5 particle integrity and stability following contrast agent incubation. EMs of rAAV2-GFP and rAAV5-GFP particles pretreated with Gd appear morphologically similar to the untreated sample; however, Gab treatment resulted in surface morphology changes and aggregation. A compromise of particle integrity was suggested by sensitivity of the packaged genome to DNAase treatment following Gab incubation but not Gd for both vectors. However, neither agent significantly affected particle stability when analyzed by DSC. An increase in Tm was observed for AAV2 in lactated Ringer’s buffer. These results thus highlight potential interactions between MRI contrast agents and AAV that might affect vector distribution and stability, as well as the stabilizing effect of lactated Ringer’s solution on AAV2. PMID:26015943

  11. Retention of Gadolinium-Based Contrast Agents in Multiple Sclerosis: Retrospective Analysis of an 18-Year Longitudinal Study.

    PubMed

    Forslin, Y; Shams, S; Hashim, F; Aspelin, P; Bergendal, G; Martola, J; Fredrikson, S; Kristoffersen-Wiberg, M; Granberg, T

    2017-07-01

    Gadolinium-based contrast agents have been associated with lasting high T1-weighted signal intensity in the dentate nucleus and globus pallidus, with histopathologically confirmed gadolinium retention. We aimed to longitudinally investigate the relationship of multiple gadolinium-based contrast agent administrations to the Signal Intensity Index in the dentate nucleus and globus pallidus and any associations with cognitive function in multiple sclerosis. The Signal Intensity Index in the dentate nucleus and globus pallidus was retrospectively evaluated on T1-weighted MR imaging in an 18-year longitudinal cohort study of 23 patients with MS receiving multiple gadolinium-based contrast agent administrations and 23 healthy age- and sex-matched controls. Participants also underwent comprehensive neuropsychological testing. Patients with MS had a higher Signal Intensity Index in the dentate nucleus ( P < .001), but not in the globus pallidus ( P = .19), compared with non-gadolinium-based contrast agent-exposed healthy controls by an unpaired t test. Increasing numbers of gadolinium-based contrast agent administrations were associated with an increased Signal Intensity Index in the dentate nucleus (β = 0.45, P < .001) and globus pallidus (β = 0.60, P < .001). This association remained stable with corrections for the age, disease duration, and physical disability for both the dentate nucleus (β = 0.43, P = .001) and globus pallidus (β = 0.58, P < .001). An increased Signal Intensity Index in the dentate nucleus among patients with MS was associated with lower verbal fluency scores, which remained significant after correction for several aspects of disease severity (β = -0.40 P = .013). Our data corroborate previous reports of lasting gadolinium retention in brain tissues. An increased Signal Intensity Index in the dentate nucleus and globus pallidus was associated with lower verbal fluency, which does not prove causality but encourages further studies on cognition and gadolinium-based contrast agent administration. © 2017 by American Journal of Neuroradiology.

  12. Europium-engineered iron oxide nanocubes with high T1 and T2 contrast abilities for MRI in living subjects

    NASA Astrophysics Data System (ADS)

    Yang, Lijiao; Zhou, Zijian; Liu, Hanyu; Wu, Changqiang; Zhang, Hui; Huang, Guoming; Ai, Hua; Gao, Jinhao

    2015-04-01

    Magnetic resonance imaging (MRI) contrast agents with both positive (T1) and negative (T2) contrast abilities are needed in clinical diagnosis for fault-free accurate detection of lesions. We report a facile synthesis of europium-engineered iron oxide (EuIO) nanocubes as T1 and T2 contrast agents for MRI in living subjects. The Eu(iii) oxide-embedded iron oxide nanoparticles significantly increase the T1 relaxivity with an enhanced positive contrast effect. EuIO nanocubes with 14 nm in diameter showed a high r1 value of 36.8 mM-1 s-1 with respect to total metal ions (Fe + Eu), which is about 3 times higher than that of Fe3O4 nanoparticles with similar size. Moreover, both r1 and r2 values of EuIO nanocubes can be tuned by varying their sizes and Eu doping ratios. After citrate coating, EuIO nanocubes can provide enhanced T1 and T2 contrast effects in small animals, particularly in the cardiac and liver regions. This work may provide an insightful strategy to design MRI contrast agents with both positive and negative contrast abilities for biomedical applications.Magnetic resonance imaging (MRI) contrast agents with both positive (T1) and negative (T2) contrast abilities are needed in clinical diagnosis for fault-free accurate detection of lesions. We report a facile synthesis of europium-engineered iron oxide (EuIO) nanocubes as T1 and T2 contrast agents for MRI in living subjects. The Eu(iii) oxide-embedded iron oxide nanoparticles significantly increase the T1 relaxivity with an enhanced positive contrast effect. EuIO nanocubes with 14 nm in diameter showed a high r1 value of 36.8 mM-1 s-1 with respect to total metal ions (Fe + Eu), which is about 3 times higher than that of Fe3O4 nanoparticles with similar size. Moreover, both r1 and r2 values of EuIO nanocubes can be tuned by varying their sizes and Eu doping ratios. After citrate coating, EuIO nanocubes can provide enhanced T1 and T2 contrast effects in small animals, particularly in the cardiac and liver regions. This work may provide an insightful strategy to design MRI contrast agents with both positive and negative contrast abilities for biomedical applications. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr00774g

  13. Speak Up: Prevent Errors in Your Child's Care

    MedlinePlus

    ... Ask if your child will be given a contrast agent. This is a liquid that makes organs and ... staff if your child has had problems with contrast agents before. Immediately alert staff if your child begins ...

  14. Utility of a prototype liposomal contrast agent for x-ray imaging of breast cancer: a proof of concept using micro-CT in small animals

    NASA Astrophysics Data System (ADS)

    Badea, C. T.; Samei, E.; Ghaghada, K.; Saunders, R.; Yuan, H.; Qi, Y.; Hedlund, L. W.; Mukundan, S.

    2008-03-01

    Imaging tumor angiogenesis in small animals is extremely challenging due to the size of the tumor vessels. Consequently, both dedicated small animal imaging systems and specialized intravascular contrast agents are required. The goal of this study was to investigate the use of a liposomal contrast agent for high-resolution micro-CT imaging of breast tumors in small animals. A liposomal blood pool agent encapsulating iodine with a concentration of 65.5 mg/ml was used with a Duke Center for In Vivo Microscopy (CIVM) prototype micro-computed tomography (micro-CT) system to image the R3230AC mammary carcinoma implanted in rats. The animals were injected with equivalent volume doses (0.02 ml/kg) of contrast agent. Micro-CT with the liposomal blood pool contrast agent ensured a signal difference between the blood and the muscle higher than 450 HU allowing the visualization of the tumors 3D vascular architecture in exquisite detail at 100-micron resolution. The micro-CT data correlated well with the histological examination of tumor tissue. We also studied the ability to detect vascular enhancement with limited angle based reconstruction, i.e. tomosynthesis. Tumor volumes and their regional vascular percentage were estimated. This imaging approach could be used to better understand tumor angiogenesis and be the basis for evaluating anti-angiogenic therapies.

  15. Diethylenetriaminepentaacetic acid-gadolinium (DTPA-Gd)-conjugated polysuccinimide derivatives as magnetic resonance imaging contrast agents.

    PubMed

    Lee, Ha Young; Jee, Hye Won; Seo, Sung Mi; Kwak, Byung Kook; Khang, Gilson; Cho, Sun Hang

    2006-01-01

    Biocompatible polysuccinimide (PSI) derivatives conjugated with diethylenetriaminepentaacetic acid gadolinium (DTPA-Gd) were prepared as magnetic resonance imaging (MRI) contrast agents. In this study, we synthesized PSI derivatives incorporating methoxy-poly(ethylene glycol) (mPEG) as hydrophilic ligand, hexadecylamine as hydrophobic ligand, and DTPA-Gd as contrast agent. PSI was synthesized by the polycondensation polymerization of aspartic acid. All the synthesized materials were characterized by proton nuclear magnetic resonance (1H NMR). Critical micellization concentrations were determined using fluorescent probes (pyrene). Micelle size and shape were measured by electro-photometer light scattering (ELS) and atomic force microscopy (AFM). The formed micelle size ranged from 100 to 300 nm. The T1-weighted MR images of the phantom prepared with PSI-mPEG-C16-(DTPA-Gd) were obtained in a 3.0 T clinical MR imager, and the conjugates showed a great potential as MRI contrast agents.

  16. Nano-sized Contrast Agents to Non-Invasively Detect Renal Inflammation by Magnetic Resonance Imaging

    PubMed Central

    Thurman, Joshua M.; Serkova, Natalie J.

    2013-01-01

    Several molecular imaging methods have been developed that employ nano-sized contrast agents to detect markers of inflammation within tissues. Renal inflammation contributes to disease progression in a wide range of autoimmune and inflammatory diseases, and a biopsy is currently the only method of definitively diagnosing active renal inflammation. However, the development of new molecular imaging methods that employ contrast agents capable of detecting particular immune cells or protein biomarkers will allow clinicians to evaluate inflammation throughout the kidneys, and to assess a patient's response to immunomodulatory drugs. These imaging tools will improve our ability to validate new therapies and to optimize the treatment of individual patients with existing therapies. This review describes the clinical need for new methods of monitoring renal inflammation, and recent advances in the development of nano-sized contrast agents for detection of inflammatory markers of renal disease. PMID:24206601

  17. Doxorubicin Delivery into Tumor Cells by Stable Cavitation without Contrast Agents.

    PubMed

    Chettab, Kamel; Mestas, Jean-Louis; Lafond, Maxime; Saadna, Djamel Eddine; Lafon, Cyril; Dumontet, Charles

    2017-02-06

    Doxorubicin, alone or in combination with other anticancer agents, is one of the most widely used chemotherapeutic agents and is administered in a wide range of cancers. However, the use of doxorubicin is limited due to its potential serious adverse reactions. Previous studies have established the ability of high intensity focused ultrasound (HIFU) in combination with various contrast agents to increase intracellular doxorubicin delivery in a targeted and noninvasive manner. In this study, we developed a new sonoporation device generating and monitoring acoustic cavitation bubbles without any addition of contrast agents. The device was used to potentiate the delivery of active doxorubicin into both adherent and suspended cell lines. Combining doxorubicin with ultrasound resulted in a significant enhancement of doxorubicin intracellular delivery and a decrease in cell viability at 48 and 72 h, in comparison to doxorubicin alone. More importantly and unlike previous investigations, our procedure does not require the addition of contrast agents to generate acoustic cavitation and to achieve high levels of doxorubicin delivery. The successful translation of this approach for an in vivo application may allow a significant reduction in the dosage and the adverse effects of doxorubicin therapy in patients.

  18. T(2) relaxation time of hyaline cartilage in presence of different gadolinium-based contrast agents.

    PubMed

    Wiener, Edzard; Settles, Marcus; Diederichs, Gerd

    2010-01-01

    The transverse relaxation time, T(2), of native cartilage is used to quantify cartilage degradation. T(2) is frequently measured after contrast administration, assuming that the impact of gadolinium-based contrast agents on cartilage T(2) is negligible. To verify this assumption the depth-dependent variation of T(2) in the presence of gadopentetate dimeglumine, gadobenate dimeglumine and gadoteridol was investigated. Furthermore, the r(2)/r(1) relaxivity ratios were quantified in different cartilage layers to demonstrate differences between T(2) and T(1) relaxation effects. Transverse high-spatial-resolution T(1)- and T(2)-maps were simultaneously acquired on a 1.5 T MR scanner before and after contrast administration in nine bovine patellae using a turbo-mixed sequence. The r(2)/r(1) ratios were calculated for each contrast agent in cartilage. Profiles of T(1), T(2) and r(2)/r(1) across cartilage thickness were generated in the absence and presence of contrast agent. The mean values in different cartilage layers were compared for global variance using the Kruskal-Wallis test and pairwise using the Mann-Whitney U-test. T(2) of unenhanced cartilage was 98 +/- 5 ms at 1 mm and 65 +/- 4 ms at 3 mm depth. Eleven hours after contrast administration significant differences (p < 0.001) were measurable for all three contrast agents. T(2) values were 58 +/- 2 and 62 +/- 3 ms for gadopentetate dimeglumine, 46 +/- 2 and 57 +/- 2 ms for gadobenate dimeglumine, and 38 +/- 2 and 42 +/- 2 ms for gadoteridol at 1 and 3 mm depths, respectively. The r(2)/r(1) relaxivity ratios across cartilage thickness were close to 1.0 (range 0.9-1.3). At 1.5 T, T(2) decreased significantly in the presence of contrast agents, more pronounced in superficial than in deep cartilage. The change in T(2) relaxation rate was similar to the change in T(1). Cartilage T(2) measurements after contrast administration will lead to systematic errors in the quantification of cartilage degradation. 2010 John Wiley & Sons, Ltd.

  19. Development of a gene expression database and related analysis programs for evaluation of anticancer compounds.

    PubMed

    Ushijima, Masaru; Mashima, Tetsuo; Tomida, Akihiro; Dan, Shingo; Saito, Sakae; Furuno, Aki; Tsukahara, Satomi; Seimiya, Hiroyuki; Yamori, Takao; Matsuura, Masaaki

    2013-03-01

    Genome-wide transcriptional expression analysis is a powerful strategy for characterizing the biological activity of anticancer compounds. It is often instructive to identify gene sets involved in the activity of a given drug compound for comparison with different compounds. Currently, however, there is no comprehensive gene expression database and related application system that is; (i) specialized in anticancer agents; (ii) easy to use; and (iii) open to the public. To develop a public gene expression database of antitumor agents, we first examined gene expression profiles in human cancer cells after exposure to 35 compounds including 25 clinically used anticancer agents. Gene signatures were extracted that were classified as upregulated or downregulated after exposure to the drug. Hierarchical clustering showed that drugs with similar mechanisms of action, such as genotoxic drugs, were clustered. Connectivity map analysis further revealed that our gene signature data reflected modes of action of the respective agents. Together with the database, we developed analysis programs that calculate scores for ranking changes in gene expression and for searching statistically significant pathways from the Kyoto Encyclopedia of Genes and Genomes database in order to analyze the datasets more easily. Our database and the analysis programs are available online at our website (http://scads.jfcr.or.jp/db/cs/). Using these systems, we successfully showed that proteasome inhibitors are selectively classified as endoplasmic reticulum stress inducers and induce atypical endoplasmic reticulum stress. Thus, our public access database and related analysis programs constitute a set of efficient tools to evaluate the mode of action of novel compounds and identify promising anticancer lead compounds. © 2012 Japanese Cancer Association.

  20. Dual-mode T1 and T2 magnetic resonance imaging contrast agent based on ultrasmall mixed gadolinium-dysprosium oxide nanoparticles: synthesis, characterization, and in vivo application

    NASA Astrophysics Data System (ADS)

    Tegafaw, Tirusew; Xu, Wenlong; Wasi Ahmad, Md; Baeck, Jong Su; Chang, Yongmin; Bae, Ji Eun; Chae, Kwon Seok; Kim, Tae Jeong; Lee, Gang Ho

    2015-09-01

    A new type of dual-mode T1 and T2 magnetic resonance imaging (MRI) contrast agent based on mixed lanthanide oxide nanoparticles was synthesized. Gd3+ (8S7/2) plays an important role in T1 MRI contrast agents because of its large electron spin magnetic moment resulting from its seven unpaired 4f-electrons, and Dy3+ (6H15/2) has the potential to be used in T2 MRI contrast agents because of its very large total electron magnetic moment: among lanthanide oxide nanoparticles, Dy2O3 nanoparticles have the largest magnetic moments at room temperature. Using these properties of Gd3+ and Dy3+ and their oxide nanoparticles, ultrasmall mixed gadolinium-dysprosium oxide (GDO) nanoparticles were synthesized and their potential to act as a dual-mode T1 and T2 MRI contrast agent was investigated in vitro and in vivo. The D-glucuronic acid coated GDO nanoparticles (davg = 1.0 nm) showed large r1 and r2 values (r2/r1 ≈ 6.6) and as a result clear dose-dependent contrast enhancements in R1 and R2 map images. Finally, the dual-mode imaging capability of the nanoparticles was confirmed by obtaining in vivo T1 and T2 MR images.

  1. Early detection of osteoarthritis in rabbits using MRI with a double-contrast agent.

    PubMed

    Onishi, Okihiro; Ikoma, Kazuya; Kido, Masamitsu; Kabuto, Yukichi; Ueshima, Keiichiro; Matsuda, Ken-Ichi; Tanaka, Masaki; Kubo, Toshikazu

    2018-03-13

    Articular cartilage degeneration has been evaluated by magnetic resonance imaging (MRI). However, this method has several problems, including its time-consuming nature and the requirement of a high magnetic field or specialized hardware. The purpose of this study was to sequentially assess early degenerative changes in rabbit knee articular cartilage using MRI with a new double-contrast agent. We induced osteoarthritis (OA) in the right knee of rabbits by anterior cruciate ligament transection and partial medial meniscectomy. Proton density-weighted images and T 2 -calculated images were obtained before and after contrast agent injection into the knee. The signal intensity ratio (SIR) values on the proton density-weighted images were calculated by dividing the signal intensity of the articular cartilage by that of joint fluid. Six rabbits were examined using MRI at 2 (designated 2-w OA) and 4 weeks (4-w OA) after the operation. Histological examination was performed 4 weeks after the operation. One rabbit was histologically examined 2 weeks after the operation. The control consisted of six rabbits that were not subjected to the operation. The SIR values, T 2 values and the thicknesses of the cartilage of the 2-w OA, 4-w OA and the control before and after contrast agent injection were analyzed. The Mankin score and OARSI (Osteoarthritis Research Society International) score were used for the histological evaluation. Significant differences in the SIR and T 2 values of the medial and lateral condyles of the femur were found between the control and the 4-w OA only after contrast agent injection. No significant differences were found in the SIR and T 2 values before contrast agent injection between the control, the 2-w OA and 4-w OA. The thickness of the articular cartilage revealed no significant differences. In the histological assessment, the Mankin score and OARSI score sequentially increased from the control to the 4-w OA. We evaluated the SIR and T 2 values of the knees in a rabbit OA model and a control model using a new double-contrast agent. MRI with this agent enabled OA detection earlier than using conventional MRI.

  2. Patent foramen ovale: diagnosis with multidetector CT--comparison with transesophageal echocardiography.

    PubMed

    Kim, Young Jin; Hur, Jin; Shim, Chi-Young; Lee, Hye-Jeong; Ha, Jong-Won; Choe, Kyu Ok; Heo, Ji Hoe; Choi, Eui-Young; Choi, Byoung Wook

    2009-01-01

    To evaluate the clinical feasibility and accuracy of 64-section multidetector computed tomography (CT) compared with transesophageal echocardiography (TEE) for diagnosis of a patent foramen ovale (PFO). Institutional review board approval was obtained for this retrospective study. The study included 152 consecutive stroke patients (mean age, 61.7 years; 98 men, 54 women) who underwent both cardiac multidetector CT and TEE. Electrocardiographically gated cardiac CT was performed with a 64-section CT scanner by using a saline-chaser contrast agent injection technique. A contrast agent jet from the contrast agent-filled left atrium (LA) to the saline-filled right atrium (RA) and channel-like appearance of the interatrial septum (IAS) were evaluated on axial and oblique sagittal CT images. Two-dimensional and Doppler TEE were performed to detect PFO. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of CT were obtained with TEE as the reference standard. A PFO was present in 26 patients at TEE. On CT images, a left-to-right contrast agent jet toward the inferior vena cava was noted in 21 patients (sensitivity, 73.1%; specificity, 98.4%; PPV, 90.5%; NPV, 94.7%). Channel-like appearance of the IAS was detected in 38 patients (sensitivity, 76.9%; specificity, 85.7%; PPV, 52.6%; NPV, 94.7%). Channel-like appearance of the IAS was noted in all patients who had a contrast agent jet. A contrast agent jet from LA to RA toward the inferior vena cava with channel-like appearance of the IAS on CT images confirms the presence of a PFO. (c) RSNA, 2008.

  3. Clinical development of BLZ-100 for real-time optical imaging of tumors during resection

    NASA Astrophysics Data System (ADS)

    Franklin, Heather L.; Miller, Dennis M.; Hedges, Teresa; Perry, Jeff; Parrish-Novak, Julia

    2016-03-01

    Complete initial resection can give cancer patients the best opportunity for long-term survival. There is unmet need in surgical oncology for optical imaging that enables simple and precise visualization of tumors and consistent contrast with surrounding normal tissues. Near-infrared (NIR) contrast agents and camera systems that can detect them represent an area of active research and development. The investigational Tumor Paint agent BLZ-100 is a conjugate of a chlorotoxin peptide and the NIR dye indocyanine green (ICG) that has been shown to specifically bind to a broad range of solid tumors. Clinical efficacy studies with BLZ-100 are in progress, a necessary step in bringing the product into clinical practice. To ensure a product that will be useful for and accepted by surgeons, the early clinical development of BLZ- 100 incorporates multiple tumor types and imaging devices so that surgeon feedback covers the range of anticipated clinical uses. Key contrast agent characteristics include safety, specificity, flexibility in timing between dose and surgery, and breadth of tumor types recognized. Imaging devices should use wavelengths that are optimal for the contrast agent, be sensitive enough that contrast agent dosing can be adjusted for optimal contrast, include real-time video display of fluorescence and white light image, and be simple for surgeons to use with minimal disruption of surgical flow. Rapid entry into clinical studies provides the best opportunity for early surgeon feedback, enabling development of agents and devices that will gain broad acceptance and provide information that helps surgeons achieve more complete and precise resections.

  4. A theoretical framework to model DSC-MRI data acquired in the presence of contrast agent extravasation

    NASA Astrophysics Data System (ADS)

    Quarles, C. C.; Gochberg, D. F.; Gore, J. C.; Yankeelov, T. E.

    2009-10-01

    Dynamic susceptibility contrast (DSC) MRI methods rely on compartmentalization of the contrast agent such that a susceptibility gradient can be induced between the contrast-containing compartment and adjacent spaces, such as between intravascular and extravascular spaces. When there is a disruption of the blood-brain barrier, as is frequently the case with brain tumors, a contrast agent leaks out of the vasculature, resulting in additional T1, T2 and T*2 relaxation effects in the extravascular space, thereby affecting the signal intensity time course and reducing the reliability of the computed hemodynamic parameters. In this study, a theoretical model describing these dynamic intra- and extravascular T1, T2 and T*2 relaxation interactions is proposed. The applicability of using the proposed model to investigate the influence of relevant MRI pulse sequences (e.g. echo time, flip angle), and physical (e.g. susceptibility calibration factors, pre-contrast relaxation rates) and physiological parameters (e.g. permeability, blood flow, compartmental volume fractions) on DSC-MRI signal time curves is demonstrated. Such a model could yield important insights into the biophysical basis of contrast-agent-extravasastion-induced effects on measured DSC-MRI signals and provide a means to investigate pulse sequence optimization and appropriate data analysis methods for the extraction of physiologically relevant imaging metrics.

  5. Evaluation of simethicone-coated cellulose as a negative oral contrast agent for abdominal CT.

    PubMed

    Sahani, Dushyant V; Jhaveri, Kartik S; D'souza, Roy V; Varghese, Jose C; Halpern, Elkan; Harisinghani, Mukesh G; Hahn, Peter F; Saini, Sanjay

    2003-05-01

    Because of the increased clinical use of computed tomography (CT) for imaging the abdominal vasculature and urinary tract, there is a need for negative contrast agents. The authors undertook this study to assess the suitability of simethicone-coated cellulose (SCC), which is approved for use as an oral contrast agent in sonography, for use as a negative oral contrast agent in abdominal CT. This prospective study involved 40 adult patients scheduled to undergo abdominal CT for the evaluation of hematuria. Prior to scanning, 20 subjects received 800 mL of SCC and 20 received 800 mL of water as an oral contrast agent. Imaging was performed with a multi-detector row helical scanner in two phases, according to the abdominal CT protocol used for hematuria evaluation at the authors' institution. The first, "early" phase began an average of 15 minutes after the ingestion of contrast material; the second, "late" phase began an average of 45 minutes after the ingestion of contrast material. Blinded analysis was performed by three abdominal radiologists separately, using a three-point scale (0 = poor, 1 = acceptable, 2 = excellent) to assess the effectiveness of SCC for marking the proximal, middle, and distal small bowel. Average scores for enhancement with SCC and with water were obtained and compared. Statistical analysis was performed with a Wilcoxon signed-rank test. SCC was assigned higher mean scores than water for enhancement in each segment of the bowel, both on early-phase images (0.8-1.35 for SCC vs 0.6-1.1 for water) and on late-phase images (1.1-1.4 vs 0.81-0.96). Bowel marking with SCC, particularly in the jejunum and ileum, also was rated better than that with water in a high percentage of patients. The differences between the scores for water and for SCC, however, were not statistically significant (P > .05). SCC is effective as a negative oral contrast agent for small bowel marking at CT.

  6. L-DOPA-Coated Manganese Oxide Nanoparticles as Dual MRI Contrast Agents and Drug-Delivery Vehicles.

    PubMed

    McDonagh, Birgitte Hjelmeland; Singh, Gurvinder; Hak, Sjoerd; Bandyopadhyay, Sulalit; Augestad, Ingrid Lovise; Peddis, Davide; Sandvig, Ioanna; Sandvig, Axel; Glomm, Wilhelm Robert

    2016-01-20

    Manganese oxide nanoparticles (MONPs) are capable of time-dependent magnetic resonance imaging contrast switching as well as releasing a surface-bound drug. MONPs give T2/T2* contrast, but dissolve and release T1-active Mn(2+) and L-3,4-dihydroxyphenylalanine. Complementary images are acquired with a single contrast agent, and applications toward Parkinson's disease are suggested. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Comparison of Different Contrast Agents in Detecting Cardiac Right-to-Left Shunt in Patients with a Patent Foramen Ovale during Contrast-Transthoracic Echocardiography

    PubMed Central

    Zhao, Enfa; Cheng, Gesheng; Wang, Yingli

    2017-01-01

    The aim of this study is to evaluate the ability of two different contrast agents to detect cardiac right-to-left shunting in patients with a patent foramen ovale during contrast transthoracic echocardiography and transesophageal echocardiography. Eighty-four patients who had migraines or experienced cryptogenic stroke were prospectively enrolled. Contrast echocardiography of the right portion of the heart was performed using an injection of either (i) 8 ml of agitated saline, 1 ml of blood, and 1 ml of air (ASB) or (ii) 4 ml of vitamin B6 and 6 ml of sodium bicarbonate solution (VSBS). All patients underwent contrast echocardiography with different contrast agents successively before undergoing transesophageal echocardiography. The diagnostic sensitivity of VSBS and ASB for cardiac shunting diagnosis was 94.23% and 78.85%, respectively. The diagnostic sensitivity in the VSBS group was significantly higher than that in the ASB group (χ2 = 5.283, P = 0.022). The observed semiquantitative shunt grading suggests that the positive rate in the VSBS group was higher than that in the ASB group (Z = −1.998, P = 0.046). The use of vitamin B6 and sodium bicarbonate solution as a TTE contrast agent yielded a high sensitivity compared with ASB. However, further trials with large sample size are required to confirm this finding. PMID:29333447

  8. Artifacts in Sonography - Part 3.

    PubMed

    Bönhof, Jörg A; McLaughlin, Glen

    2018-06-01

    As a continuation of parts 1 1 and 2 2, this article discusses artifacts as caused by insufficient temporal resolution, artifacts in color and spectral Doppler sonography, and information regarding artifacts in sonography with contrast agents. There are artifacts that occur in B-mode sonography as well as in Doppler imaging methods and sonography with contrast agents, such as slice thickness artifacts and bow artifacts, shadows, mirroring, and artifacts due to refraction that appear, for example, as double images, because they are based on the same formation mechanisms. In addition, there are artifacts specific to Doppler sonography, such as the twinkling artifact, and method-based motion artifacts, such as aliasing, the ureteric jet, and due to tissue vibration. The artifacts specific to contrast mode include echoes from usually highly reflective structures that are not contrast bubbles ("leakage"). Contrast agent can also change the transmitting signal so that even structures not containing contrast agent are echogenic ("pseudoenhancement"). While artifacts can cause problems regarding differential diagnosis, they can also be useful for determining the diagnosis. Therefore, effective use of sonography requires both profound knowledge and skilled interpretation of artifacts. © Georg Thieme Verlag KG Stuttgart · New York.

  9. In vivo photoacoustic tumor tomography using a quinoline-annulated porphyrin as NIR molecular contrast agent.

    PubMed

    Luciano, Michael; Erfanzadeh, Mohsen; Zhou, Feifei; Zhu, Hua; Bornhütter, Tobias; Röder, Beate; Zhu, Quing; Brückner, Christian

    2017-01-25

    The synthesis and photophysical properties of a tetra-PEG-modified and freely water-soluble quinoline-annulated porphyrin are described. We previously demonstrated the ability of quinoline-annulated porphyrins to act as an in vitro NIR photoacoustic imaging (PAI) contrast agent. The solubility of the quinoline-annulated porphyrin derivative in serum now allowed the assessment of the efficacy of the PEGylated derivative as an in vivo NIR contrast agent for the PAI of an implanted tumor in a mouse model. A multi-fold contrast enhancement when compared to the benchmark dye ICG could be shown, a finding that could be traced to its photophysical properties (short triplet lifetimes, low fluorescence and singlet oxygen sensitization quantum yields). A NIR excitation wavelength of 790 nm could be used, fully taking advantage of the optical window of tissue. Rapid renal clearance of the dye was observed. Its straight-forward synthesis, optical properties with the possibility for further optical fine-tuning, nontoxicity, favorable elimination rates, and contrast enhancement make this a promising PAI contrast agent. The ability to conjugate the PAI chromophore with a fluorescent tag using a facile and general conjugation strategy was also demonstrated.

  10. Instrumentation for contrast echocardiography: technology and techniques.

    PubMed

    Kaul, Sanjiv

    2002-11-18

    Contrast echocardiography is the only clinical imaging technique in which the imaging modality (ultrasound) can cause a change in the contrast agent (microbubbles). The change in the contrast agent can range from small oscillations of the microbubbles at a low mechanical index to their disruption at a high mechanical index. The specific mechanical index required to produce these various effects may be different for each contrast agent, depending on the bubble dimension as well as shell and gas characteristics. These alterations in bubbles result in changes in ultrasound backscatter that are specific for the bubbles themselves, rather than for tissue, and are therefore exploited for imaging their presence in tissue. These signal-processing techniques have resulted in an increased signal-to-noise ratio from bubbles vis-à-vis the tissue and have made online assessment of myocardial perfusion possible.

  11. A knowledge base architecture for distributed knowledge agents

    NASA Technical Reports Server (NTRS)

    Riedesel, Joel; Walls, Bryan

    1990-01-01

    A tuple space based object oriented model for knowledge base representation and interpretation is presented. An architecture for managing distributed knowledge agents is then implemented within the model. The general model is based upon a database implementation of a tuple space. Objects are then defined as an additional layer upon the database. The tuple space may or may not be distributed depending upon the database implementation. A language for representing knowledge and inference strategy is defined whose implementation takes advantage of the tuple space. The general model may then be instantiated in many different forms, each of which may be a distinct knowledge agent. Knowledge agents may communicate using tuple space mechanisms as in the LINDA model as well as using more well known message passing mechanisms. An implementation of the model is presented describing strategies used to keep inference tractable without giving up expressivity. An example applied to a power management and distribution network for Space Station Freedom is given.

  12. [Contrast medium enhanced magnetic resonance tomography of liver metastases: positive versus negative contrast media].

    PubMed

    Hammerstingl, R M; Schwarz, W; Hochmuth, K; Staib-Sebler, E; Lorenz, M; Vogl, T J

    2001-01-01

    The development in oncologic liver surgery as well as modified interventional therapy strategies of the liver have resulted in improved diagnostic imaging. The evolution of contrast agents for MR imaging of the liver has proceeded along several different paths with the common goal of improving liver-lesion contrast. In MRI contrast agents act indirectly by their effects on relaxation times. Contrast agents used for hepatic MR imaging can be categorized in those that target the extracellular space, the hepatobiliary system, and the reticuloendothelial system. The first two result in a positive enhancement, the last one in a negative enhancement. Positive enhancers allow a better characterization of liver metastases using dynamic sequence protocols. Detection rate of liver metastases is increased using hepatobiliary contrast-enhanced MRI compared to unenhanced MRI. Negative enhancers, iron oxide particles, significantly increase tumor-to-liver contrast and allow detection of more lesions than other diagnostic methods. Iron-oxide enhanced MRI enables differential diagnosis of liver metastases comparing morphologic features using T2 and T1-weighted sequences.

  13. Neutral vs positive oral contrast in diagnosing acute appendicitis with contrast-enhanced CT: sensitivity, specificity, reader confidence and interpretation time

    PubMed Central

    Naeger, D M; Chang, S D; Kolli, P; Shah, V; Huang, W; Thoeni, R F

    2011-01-01

    Objective The study compared the sensitivity, specificity, confidence and interpretation time of readers of differing experience in diagnosing acute appendicitis with contrast-enhanced CT using neutral vs positive oral contrast agents. Methods Contrast-enhanced CT for right lower quadrant or right flank pain was performed in 200 patients with neutral and 200 with positive oral contrast including 199 with proven acute appendicitis and 201 with other diagnoses. Test set disease prevalence was 50%. Two experienced gastrointestinal radiologists, one fellow and two first-year residents blindly assessed all studies for appendicitis (2000 readings) and assigned confidence scores (1=poor to 4=excellent). Receiver operating characteristic (ROC) curves were generated. Total interpretation time was recorded. Each reader's interpretation with the two agents was compared using standard statistical methods. Results Average reader sensitivity was found to be 96% (range 91–99%) with positive and 95% (89–98%) with neutral oral contrast; specificity was 96% (92–98%) and 94% (90–97%). For each reader, no statistically significant difference was found between the two agents (sensitivities p-values >0.6; specificities p-values>0.08), in the area under the ROC curve (range 0.95–0.99) or in average interpretation times. In cases without appendicitis, positive oral contrast demonstrated improved appendix identification (average 90% vs 78%) and higher confidence scores for three readers. Average interpretation times showed no statistically significant differences between the agents. Conclusion Neutral vs positive oral contrast does not affect the accuracy of contrast-enhanced CT for diagnosing acute appendicitis. Although positive oral contrast might help to identify normal appendices, we continue to use neutral oral contrast given its other potential benefits. PMID:20959365

  14. Effects of the magnetic resonance imaging contrast agent Gd-DTPA on plant growth and root imaging in rice.

    PubMed

    Liu, Zan; Qian, Junchao; Liu, Binmei; Wang, Qi; Ni, Xiaoyu; Dong, Yaling; Zhong, Kai; Wu, Yuejin

    2014-01-01

    Although paramagnetic contrast agents have a wide range of applications in medical studies involving magnetic resonance imaging (MRI), these agents are seldom used to enhance MRI images of plant root systems. To extend the application of MRI contrast agents to plant research and to develop related techniques to study root systems, we examined the applicability of the MRI contrast agent Gd-DTPA to the imaging of rice roots. Specifically, we examined the biological effects of various concentrations of Gd-DTPA on rice growth and MRI images. Analysis of electrical conductivity and plant height demonstrated that 5 mmol Gd-DTPA had little impact on rice in the short-term. The results of signal intensity and spin-lattice relaxation time (T1) analysis suggested that 5 mmol Gd-DTPA was the appropriate concentration for enhancing MRI signals. In addition, examination of the long-term effects of Gd-DTPA on plant height showed that levels of this compound up to 5 mmol had little impact on rice growth and (to some extent) increased the biomass of rice.

  15. Validation of diffuse optical tomography using a bi-functional optical-MRI contrast agent and a hybrid MRI-DOT system

    NASA Astrophysics Data System (ADS)

    Luk, Alex T.; Lin, Yuting; Grimmond, Brian; Sood, Anup; Uzgiris, Egidijus E.; Nalcioglu, Orhan; Gulsen, Gultekin

    2013-03-01

    Since diffuse optical tomography (DOT) is a low spatial resolution modality, it is desirable to validate its quantitative accuracy with another well-established imaging modality, such as magnetic resonance imaging (MRI). In this work, we have used a polymer based bi-functional MRI-optical contrast agent (Gd-DTPA-polylysine-IR800) in collaboration with GE Global Research. This multi-modality contrast agent provided not only co-localization but also the same kinetics, to cross-validate two imaging modalities. Bi-functional agents are injected to the rats and pharmacokinetics at the bladder are recovered using both optical and MR imaging. DOT results are validated using MRI results as "gold standard"

  16. Dual-contrast agent photon-counting computed tomography of the heart: initial experience.

    PubMed

    Symons, Rolf; Cork, Tyler E; Lakshmanan, Manu N; Evers, Robert; Davies-Venn, Cynthia; Rice, Kelly A; Thomas, Marvin L; Liu, Chia-Ying; Kappler, Steffen; Ulzheimer, Stefan; Sandfort, Veit; Bluemke, David A; Pourmorteza, Amir

    2017-08-01

    To determine the feasibility of dual-contrast agent imaging of the heart using photon-counting detector (PCD) computed tomography (CT) to simultaneously assess both first-pass and late enhancement of the myocardium. An occlusion-reperfusion canine model of myocardial infarction was used. Gadolinium-based contrast was injected 10 min prior to PCD CT. Iodinated contrast was infused immediately prior to PCD CT, thus capturing late gadolinium enhancement as well as first-pass iodine enhancement. Gadolinium and iodine maps were calculated using a linear material decomposition technique and compared to single-energy (conventional) images. PCD images were compared to in vivo and ex vivo magnetic resonance imaging (MRI) and histology. For infarct versus remote myocardium, contrast-to-noise ratio (CNR) was maximal on late enhancement gadolinium maps (CNR 9.0 ± 0.8, 6.6 ± 0.7, and 0.4 ± 0.4, p < 0.001 for gadolinium maps, single-energy images, and iodine maps, respectively). For infarct versus blood pool, CNR was maximum for iodine maps (CNR 11.8 ± 1.3, 3.8 ± 1.0, and 1.3 ± 0.4, p < 0.001 for iodine maps, gadolinium maps, and single-energy images, respectively). Combined first-pass iodine and late gadolinium maps allowed quantitative separation of blood pool, scar, and remote myocardium. MRI and histology analysis confirmed accurate PCD CT delineation of scar. Simultaneous multi-contrast agent cardiac imaging is feasible with photon-counting detector CT. These initial proof-of-concept results may provide incentives to develop new k-edge contrast agents, to investigate possible interactions between multiple simultaneously administered contrast agents, and to ultimately bring them to clinical practice.

  17. Influence of different iodinated contrast media on the induction of DNA double-strand breaks after in vitro X-ray irradiation.

    PubMed

    Deinzer, Christoph K W; Danova, Daniela; Kleb, Beate; Klose, Klaus J; Heverhagen, Johannes T

    2014-01-01

    The objective of this work was to examine differences in DNA double-strand break induction in peripheral blood lymphocytes after in vitro X-ray irradiation between iodinated contrast agents. Four different iodinated X-ray contrast agents--three of them with two different iodine concentrations--and mannitol (negative control; concentration of 150 mg mannitol per ml blood) were pipetted into blood samples so that there was a concentration of 0, 7.5 or 15 mg of iodine per ml blood in the samples. Negative controls without contrast medium (0 mg of iodine per ml blood) were also processed for every irradiation dose. The tubes were exposed to 0, 20 or 500 mGy in vitro X-ray irradiation. After that, the lymphocytes were separated by using density-gradient centrifugation. Fluorescence microscopy was applied to determine the average number of γH2AX-foci per lymphocyte in the presence or absence of different contrast media or mannitol. Differences in the number of γH2AX-foci were statistically analysed by one-way ANOVA and post-hoc Tukey's honestly significant difference test. Iodinated contrast agents led to a statistically significant increase in DNA double-strand breaks after in vitro irradiation. This effect increased statistically significant with rising radiation dose and appeared independent of the contrast agent used (iopromid, iodixanol, iomeprol, iopamidol). A statistically significant difference in DNA damage between the different tested contrast agents was not found. Therefore, the increase in DNA double-strand breaks depends solely on the amount of iodine applied. For evaluation of clinical consequences, our findings could be tested in further animal studies. Copyright © 2014 John Wiley & Sons, Ltd.

  18. Molecular nanomagnets as contrast agents for Magnetic Resonance Imaging

    NASA Astrophysics Data System (ADS)

    Rodríguez, Elisenda; Roig, Anna; Molins, Elies; Arús, Carles; Cabañas, Miquel; Quintero, María Rosa; Cerdán, Sebastián; Sanfeliu, Coral

    2003-03-01

    Magnetic resonance imaging (MRI) is a non-invasive technique used in medicine to produce high quality images of human body slices. In order to enhance the contrast between different organs or to reveal altered portions of them such necrosis or tumors, the administration of a contrast agent is highly convenient. Currently Gd-DTPA, a paramagnetic complex, is the most widely administered compound. In this context, we have assayed molecular nanomagnets as MRI contrast agents. The complex [(tacn)_6Fe_8(μ_3-O)_2(μ_2-OH)_12]Br_8·9H_2O^1(Fe8 in brief) has been evaluated and shorter relaxation times, T1 and T_2, have been obtained for Fe8 than those obtained for the commercial Gd-DTPA. No toxic effects have been observed at concentrations up to 1 mM of Fe8 in cultured cells. Phantom studies with T_1-weighted MRI at 9.4 Tesla suggest that Fe8 can have potentiality as T_1-contrast agent. ^1Wieghardt K Angew Chem Intl Ed Engl 23 1 (1984) 77

  19. Photoacoustic/ultrasound dual-modality contrast agent and its application to thermotherapy.

    PubMed

    Wang, Yu-Hsin; Liao, Ai-Ho; Chen, Jui-Hao; Wang, Churng-Ren Chris; Li, Pai-Chi

    2012-04-01

    This study investigates a photoacoustic/ultrasound dual-modality contrast agent, including extending its applications from image-contrast enhancement to combined diagnosis and therapy with site-specific targeting. The contrast agent comprises albumin-shelled microbubbles with encapsulated gold nanorods (AuMBs). The gas-filled microbubbles, whose diameters range from submicrometer to several micrometers, are not only echogenic but also can serve as drug-delivery vehicles. The gold nanorods are used to enhance the generation of both photoacoustic and photothermal signals. The optical absorption peak of the gold nanorods is tuned to 760 nm and is invariant after microbubble encapsulation. Dual-modality contrast enhancement is first described here, and the applications to cellular targeting and laser-induced thermotherapy in a phantom are demonstrated. Photoacoustic imaging can be used to monitor temperature increases during the treatment. The targeting capability of AuMBs was verified, and the temperature increased by 26°C for a laser power of 980 mW, demonstrating the potential of combined diagnosis and therapy with the dual-modality agent. Targeted photo- or acoustic-mediated delivery is also possible.

  20. Gadofosveset-enhanced magnetic resonance angiography as a means of evaluating pulmonary arteriovenous malformation: a case report.

    PubMed

    Pressacco, Josephine; Papas, Konstantin

    2012-07-01

    This case report is a unique presentation of a new potential indication for Gadofosvest (Ablavar), a blood pool contrast agent for magnetic resonance angiography (MRA). Ablavar is an excellent MRA contrast agent because it provides optimal contrast opacification of both the arterial and venous system, unlike the conventional extracellular agents that are used for arterial imaging only. The present case report demonstrates the ability of Ablavar to demonstrate pulmonary arteriovenous malformation (AVM), showing both its arterial feeders as well as its venous drainage tract. Crown Copyright © 2012. Published by Elsevier Inc. All rights reserved.

  1. Stability analysis of ultrasound thick-shell contrast agents

    PubMed Central

    Lu, Xiaozhen; Chahine, Georges L.; Hsiao, Chao-Tsung

    2012-01-01

    The stability of thick shell encapsulated bubbles is studied analytically. 3-D small perturbations are introduced to the spherical oscillations of a contrast agent bubble in response to a sinusoidal acoustic field with different amplitudes of excitation. The equations of the perturbation amplitudes are derived using asymptotic expansions and linear stability analysis is then applied to the resulting differential equations. The stability of the encapsulated microbubbles to nonspherical small perturbations is examined by solving an eigenvalue problem. The approach then identifies the fastest growing perturbations which could lead to the breakup of the encapsulated microbubble or contrast agent. PMID:22280568

  2. Synchrotron-based intra-venous K-edge digital subtraction angiography in a pig model: a feasibility study.

    PubMed

    Schültke, Elisabeth; Fiedler, Stefan; Nemoz, Christian; Ogieglo, Lissa; Kelly, Michael E; Crawford, Paul; Esteve, Francois; Brochard, Thierry; Renier, Michel; Requardt, Herwig; Le Duc, Geraldine; Juurlink, Bernhard; Meguro, Kotoo

    2010-03-01

    K-edge digital subtraction angiography (KEDSA) combined with the tunability of synchrotron beam yields an imaging technique that is highly sensitive to low concentrations of contrast agents. Thus, contrast agent can be administered intravenously, obviating the need for insertion of a guided catheter to deliver a bolus of contrast agent close to the target tissue. With the high-resolution detectors used at synchrotron facilities, images can be acquired at high spatial resolution. Thus, the KEDSA appears particularly suited for studies of neurovascular pathology in animal models, where the vascular diameters are significantly smaller than in human patients. This feasibility study was designed to test the suitability of KEDSA after intravenous injection of iodine-based contrast agent for use in a pig model. Four adult male pigs were used for our experiments. Neurovascular angiographic images were acquired using KEDSA with a solid state Germanium (Ge) detector at the European Synchrotron Radiation Facility (ESRF) in Grenoble, France. After intravenous injection of 0.9 ml/kg iodinated contrast agent (Xenetix), the peak iodine concentrations in the internal carotid and middle cerebral arteries reached 35 mg/ml. KEDSA images in radiography mode allowed the visualization of intracranial arteries of less than 1.5mm diameter. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.

  3. Dual-mode imaging with radiolabeled gold nanorods

    NASA Astrophysics Data System (ADS)

    Agarwal, Ashish; Shao, Xia; Rajian, Justin R.; Zhang, Huanan; Chamberland, David L.; Kotov, Nicholas A.; Wang, Xueding

    2011-05-01

    Many nanoparticle contrast agents have difficulties with deep tissue and near-bone imaging due to limited penetration of visible photons in the body and mineralized tissues. We are looking into the possibility of mediating this problem while retaining the capabilities of the high spatial resolution associated with optical imaging. As such, the potential combination of emerging photoacoustic imaging and nuclear imaging in monitoring of antirheumatic drug delivery by using a newly developed dual-modality contrast agent is investigated. The contrast agent is composed of gold nanorods (GNRs) conjugated to the tumor necrosis factor (TNF-α) antibody and is subsequently radiolabeled by 125I. ELISA experiments designed to test TNF-α binding are performed to prove the specificity and biological activity of the radiolabeled conjugated contrast agent. Photoacoustic and nuclear imaging are performed to visualize the distribution of GNRs in articular tissues of the rat tail joints in situ. Findings from the two imaging modalities correspond well with each other in all experiments. Our system can image GNRs down to a concentration of 10 pM in biological tissues and with a radioactive label of 5 μCi. This study demonstrates the potential of combining photoacoustic and nuclear imaging modalities through one targeted contrast agent for noninvasive monitoring of drug delivery as well as deep and mineralized tissue imaging.

  4. Superhydrophobic silica nanoparticles as ultrasound contrast agents.

    PubMed

    Jin, Qiaofeng; Lin, Chih-Yu; Kang, Shih-Tsung; Chang, Yuan-Chih; Zheng, Hairong; Yang, Chia-Min; Yeh, Chih-Kuang

    2017-05-01

    Microbubbles have been widely studied as ultrasound contrast agents for diagnosis and as drug/gene carriers for therapy. However, their size and stability (lifetime of 5-12min) limited their applications. The development of stable nanoscale ultrasound contrast agents would therefore benefit both. Generating bubbles persistently in situ would be one of the promising solutions to the problem of short lifetime. We hypothesized that bubbles could be generated in situ by providing stable air nuclei since it has been found that the interfacial nanobubbles on a hydrophobic surface have a much longer lifetime (orders of days). Mesoporous silica nanoparticles (MSNs) with large surface areas and different levels of hydrophobicity were prepared to test our hypothesis. It is clear that the superhydrophobic and porous nanoparticles exhibited a significant and strong contrast intensity compared with other nanoparticles. The bubbles generated from superhydrophobic nanoparticles sustained for at least 30min at a MI of 1.0, while lipid microbubble lasted for about 5min at the same settings. In summary MSNs have been transformed into reliable bubble precursors by making simple superhydrophobic modification, and made into a promising contrast agent with the potentials to serve as theranostic agents that are sensitive to ultrasound stimulation. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Melanin-Based Contrast Agents for Biomedical Optoacoustic Imaging and Theranostic Applications.

    PubMed

    Longo, Dario Livio; Stefania, Rachele; Aime, Silvio; Oraevsky, Alexander

    2017-08-07

    Optoacoustic imaging emerged in early 1990s as a new biomedical imaging technology that generates images by illuminating tissues with short laser pulses and detecting resulting ultrasound waves. This technique takes advantage of the spectroscopic approach to molecular imaging, and delivers high-resolution images in the depth of tissue. Resolution of the optoacoustic imaging is scalable, so that biomedical systems from cellular organelles to large organs can be visualized and, more importantly, characterized based on their optical absorption coefficient, which is proportional to the concentration of absorbing chromophores. Optoacoustic imaging was shown to be useful in both preclinical research using small animal models and in clinical applications. Applications in the field of molecular imaging offer abundant opportunities for the development of highly specific and effective contrast agents for quantitative optoacoustic imaging. Recent efforts are being made in the direction of nontoxic biodegradable contrast agents (such as nanoparticles made of melanin) that are potentially applicable in clinical optoacoustic imaging. In order to increase the efficiency and specificity of contrast agents and probes, they need to be made smart and capable of controlled accumulation in the target cells. This review was written in recognition of the potential breakthroughs in medical optoacoustic imaging that can be enabled by efficient and nontoxic melanin-based optoacoustic contrast agents.

  6. Melanin-Based Contrast Agents for Biomedical Optoacoustic Imaging and Theranostic Applications

    PubMed Central

    Longo, Dario Livio; Aime, Silvio

    2017-01-01

    Optoacoustic imaging emerged in early 1990s as a new biomedical imaging technology that generates images by illuminating tissues with short laser pulses and detecting resulting ultrasound waves. This technique takes advantage of the spectroscopic approach to molecular imaging, and delivers high-resolution images in the depth of tissue. Resolution of the optoacoustic imaging is scalable, so that biomedical systems from cellular organelles to large organs can be visualized and, more importantly, characterized based on their optical absorption coefficient, which is proportional to the concentration of absorbing chromophores. Optoacoustic imaging was shown to be useful in both preclinical research using small animal models and in clinical applications. Applications in the field of molecular imaging offer abundant opportunities for the development of highly specific and effective contrast agents for quantitative optoacoustic imaging. Recent efforts are being made in the direction of nontoxic biodegradable contrast agents (such as nanoparticles made of melanin) that are potentially applicable in clinical optoacoustic imaging. In order to increase the efficiency and specificity of contrast agents and probes, they need to be made smart and capable of controlled accumulation in the target cells. This review was written in recognition of the potential breakthroughs in medical optoacoustic imaging that can be enabled by efficient and nontoxic melanin-based optoacoustic contrast agents. PMID:28783106

  7. Radiation exposure and contrast agent use related to radial versus femoral arterial access during percutaneous coronary intervention (PCI)-Results of the FERARI study.

    PubMed

    Becher, Tobias; Behnes, Michael; Ünsal, Melike; Baumann, Stefan; El-Battrawy, Ibrahim; Fastner, Christian; Kuschyk, Jürgen; Papavassiliu, Theano; Hoffmann, Ursula; Mashayekhi, Kambis; Borggrefe, Martin; Akin, Ibrahim

    2016-12-01

    Data regarding radiation exposure related to radial versus femoral arterial access in patients undergoing percutaneous coronary intervention (PCI) remain controversial. This study aims to evaluate patients enrolled in the FERARI study regarding radiation exposure, fluoroscopy time and contrast agent use. The Femoral Closure versus Radial Compression Devices Related to Percutaneous Coronary Interventions (FERARI) study evaluated prospectively 400 patients between February 2014 and May 2015 undergoing PCI either using the radial or femoral access. In these 400 patients, baseline characteristics, procedural data such as procedural duration, fluoroscopy time, dose-area product (DAP) as well as the amount of contrast agent used were documented and analyzed. Median fluoroscopy time was not significantly different in patients undergoing radial versus femoral access (12.2 vs. 9.8min, p=0.507). Furthermore, median DAP (54.5 vs. 52.0 Gycm2, p=0.826), procedural duration (46.0 vs. 45.0min, p=0.363) and contrast agent use (185.5 vs. 199.5ml, p=0.742) were also similar in radial and femoral PCI. There was no difference regarding median fluoroscopy time, procedural duration, radiation dose or contrast agent use between radial versus femoral arterial access in PCI. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Aptamer-Targeted Magnetic Resonance Imaging Contrast Agents and Their Applications.

    PubMed

    Zhang, Yajie; Zhang, Tingting; Liu, Min; Kuang, Ye; Zu, Guangyue; Zhang, Kunchi; Cao, Yi; Pei, Renjun

    2018-06-01

    Magnetic resonance imaging is a powerful diagnostic technology with high spatial resolution and non-invasion. The contrast agents have significant effect on the resolution of the MR imaging. However, the commercial contrast agents (CAs) usually consist of individual Gd3+ chelated with a low molecular weight acyclic or cyclic ligand, and these small-molecule CAs are usually subjected to nonspecificity, thus leading to rapid renal clearance and modest contrast enhancement for tumor imaging. In recent years, the nanostructured materials conjugated with aptamers were widely used and opened a new door in biomedical imaging due to excellent specificity, non-immunogenicity, easily synthesis and chemical modification of aptamers. This review summarizes all kinds of aptamertargeted MRI CAs and their applications.

  9. Biocompatible blood pool MRI contrast agents based on hyaluronan

    PubMed Central

    Zhu, Wenlian; Artemov, Dmitri

    2010-01-01

    Biocompatible gadolinium blood pool contrast agents based on a biopolymer, hyaluronan, were investigated for magnetic resonance angiography application. Hyaluronan, a non-sulfated linear glucosaminoglycan composed of 2000–25,000 repeating disaccharide subunits of D-glucuronic acid and N-acetylglucosamine with molecular weight up to 20 MDa, is a major component of the extracellular matrix. Two gadolinium contrast agents based on 16 and 74 kDa hyaluronan were synthesized, both with R1 relaxivity around 5 mM−1 s−1 per gadolinium at 9.4 T at 25°C. These two hyaluronan based agents show significant enhancement of the vasculature for an extended period of time. Initial excretion was primarily through the renal system. Later uptake was observed in the stomach and lower gastrointestinal tract. Macromolecular hyaluronan-based gadolinium agents have a high clinical translation potential as hyaluronan is already approved by FDA for a variety of medical applications. PMID:21504061

  10. The potential for neurovascular intravenous angiography using K-edge digital subtraction angiography

    NASA Astrophysics Data System (ADS)

    Schültke, E.; Fiedler, S.; Kelly, M.; Griebel, R.; Juurlink, B.; LeDuc, G.; Estève, F.; Le Bas, J.-F.; Renier, M.; Nemoz, C.; Meguro, K.

    2005-08-01

    Background: Catheterization of small-caliber blood vessels in the central nervous system can be extremely challenging. Alternatively, intravenous (i.v.) administration of contrast agent is minimally invasive and therefore carries a much lower risk for the patient. With conventional X-ray equipment, volumes of contrast agent that could be safely administered to the patient do not allow acquisition of high-quality images after i.v. injection, because the contrast bolus is extremely diluted by passage through the heart. However, synchrotron-based digital K-edge subtraction angiography does allow acquisition of high-quality images after i.v. administration of relatively small doses of contrast agent. Materials and methods: Eight adult male New Zealand rabbits were used for our experiments. Animals were submitted to both angiography with conventional X-ray equipment and synchrotron-based digital subtraction angiography. Results: With conventional X-ray equipment, no contrast was seen in either cerebral or spinal blood vessels after i.v. injection of iodinated contrast agent. However, using K-edge digital subtraction angiography, as little as 1 ml iodinated contrast agent, when administered as i.v. bolus, yielded images of small-caliber blood vessels in the central nervous system (both brain and spinal cord). Conclusions: If it would be possible to image blood vessels of the same diameter in the central nervous system of human patients, the synchrotron-based technique could yield high-quality images at a significantly lower risk for the patient than conventional X-ray imaging. Images could be acquired where catheterization of feeding blood vessels has proven impossible.

  11. A novel blood-pooling MR contrast agent: Carboxymethyl-diethylaminoethyl dextran magnetite.

    PubMed

    Sonoda, Akinaga; Nitta, Norihisa; Tsuchiya, Keiko; Nitta-Seko, Ayumi; Ohta, Shinichi; Otani, Hideji; Murata, Kiyoshi

    2016-12-01

    Gadofosveset trisodium is available as a prolonged pooling vascular contrast agent for magnetic resonance imaging. As gadolinium (Gd)-based agents may increase the risk for nephrogenic systemic fibrosis in patients with severe renal insufficiency, the present study synthesized carboxymethyl-diethylaminoethyl dextran magnetite (CMEADM) particles as a blood-pooling, non-Gd‑based contrast agent. CMEADM particles carry a negative or positive charge due to the binding of amino and carboxyl groups to the hydroxyl group of dextran. The present study evaluated whether the degree of charge alters the blood‑pooling time. The evaluation was performed by injecting four groups of three Japanese white rabbits each with CMEADM‑, CMEADM2‑, CMEADM+ (surface charges: ‑10.4, ‑41.0 and +9.6 mV, respectively) or with ultrasmall superparamagnetic iron oxide (USPIO; ‑11.5 mV). The relative signal intensity (SIrel) of each was calculated using the following formula: SIrel = (SI post‑contrast ‑ SI pre‑contrast / SI pre‑contrast) x 100. Following injection with the CMEADMs, but not with USPIO, the in vivo pooling time was prolonged to >300 min. No significant differences were attributable to the electric charge among the CMEADM‑, CMEADM2‑ or and CMEADM+ particles when analyzed with analysis of variance and Tukey's HSD test. Taken together, all three differently‑charged CMEADM2 particles exhibited prolonged vascular enhancing effects, compared with the USPIO. The degree of charge of the contrast agents used in the present study did not result in alteration of the prolonged blood pooling time.

  12. Automatic spectral imaging protocol selection and iterative reconstruction in abdominal CT with reduced contrast agent dose: initial experience.

    PubMed

    Lv, Peijie; Liu, Jie; Chai, Yaru; Yan, Xiaopeng; Gao, Jianbo; Dong, Junqiang

    2017-01-01

    To evaluate the feasibility, image quality, and radiation dose of automatic spectral imaging protocol selection (ASIS) and adaptive statistical iterative reconstruction (ASIR) with reduced contrast agent dose in abdominal multiphase CT. One hundred and sixty patients were randomly divided into two scan protocols (n = 80 each; protocol A, 120 kVp/450 mgI/kg, filtered back projection algorithm (FBP); protocol B, spectral CT imaging with ASIS and 40 to 70 keV monochromatic images generated per 300 mgI/kg, ASIR algorithm. Quantitative parameters (image noise and contrast-to-noise ratios [CNRs]) and qualitative visual parameters (image noise, small structures, organ enhancement, and overall image quality) were compared. Monochromatic images at 50 keV and 60 keV provided similar or lower image noise, but higher contrast and overall image quality as compared with 120-kVp images. Despite the higher image noise, 40-keV images showed similar overall image quality compared to 120-kVp images. Radiation dose did not differ between the two protocols, while contrast agent dose in protocol B was reduced by 33 %. Application of ASIR and ASIS to monochromatic imaging from 40 to 60 keV allowed contrast agent dose reduction with adequate image quality and without increasing radiation dose compared to 120 kVp with FBP. • Automatic spectral imaging protocol selection provides appropriate scan protocols. • Abdominal CT is feasible using spectral imaging and 300 mgI/kg contrast agent. • 50-keV monochromatic images with 50 % ASIR provide optimal image quality.

  13. The Subharmonic Behavior and Thresholds of High Frequency Ultrasound Contrast Agents

    NASA Astrophysics Data System (ADS)

    Allen, John

    2016-11-01

    Ultrasound contrast agents are encapsulated micro-bubbles used for diagnostic and therapeutic biomedical ultrasound. The agents oscillate nonlinearly about their equilibrium radii upon sufficient acoustic forcing and produce unique acoustic signatures that allow them to be distinguished from scattering from the surrounding tissue. The subharmonic response occurs below the fundamental and is associated with an acoustic pressure threshold. Subharmonic imaging using ultrasound contrast agents has been established for clinical applications at standard diagnostic frequencies typically below 20 MHz. However, for emerging applications of high frequency applications (above 20 MHz) subharmonic imaging is an area of on-going research. The effects of attenuation from tissue are more significant and the characterization of agents is not as well understood. Due to specificity and control production, polymer agents are useful for high frequency applications. In this study, we highlight novel measurement techniques to measure and characterize the mechanical properties of the shell of polymer contrast agents. The definition of the subharmonic threshold is investigated with respect to mono-frequency and chirp forcing waveforms which have been used to achieve optimal subharmonic content in the backscattered signal. Time frequency analysis using the Empirical Mode Decomposition (EMD) and the Hilbert-Huang transform facilitates a more sensitive and robust methodology for characterization of subharmonic content with respect to non-stationary forcing. A new definition of the subharmonic threshold is proposed with respect to the energy content of the associated adaptive basis decomposition. Additional studies with respect to targeted agent behavior and cardiovascular disease are discussed. NIH, ONR.

  14. Spin-lock imaging of exogenous exchange-based contrast agents to assess tissue pH.

    PubMed

    Zu, Zhongliang; Li, Hua; Jiang, Xiaoyu; Gore, John C

    2018-01-01

    Some X-ray contrast agents contain exchangeable protons that give rise to exchange-based effects on MRI, including chemical exchange saturation transfer (CEST). However, CEST has poor specificity to explicit exchange parameters. Spin-lock sequences at high field are also sensitive to chemical exchange. Here, we evaluate whether spin-locking techniques can detect the contrast agent iohexol in vivo after intravenous administration, and their potential for measuring changes in tissue pH. Two metrics of contrast based on R 1ρ , the spin lattice relaxation rate in the rotating frame, were derived from the behavior of R 1ρ at different locking fields. Solutions containing iohexol at different concentrations and pH were used to evaluate the ability of the two metrics to quantify exchange effects. Images were also acquired from rat brains bearing tumors before and after intravenous injections of iohexol to evaluate the potential of spin-lock techniques for detecting the agent and pH variations. The two metrics were found to depend separately on either agent concentration or pH. Spin-lock imaging may therefore provide specific quantification of iohexol concentration and the iohexol-water exchange rate, which reports on pH. Spin-lock techniques may be used to assess the dynamics of intravenous contrast agents and detect extracellular acidification. Magn Reson Med 79:298-305, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  15. Gd-DTPA T1 relaxivity in brain tissue obtained by convection-enhanced delivery, magnetic resonance imaging and emission spectroscopy

    NASA Astrophysics Data System (ADS)

    Haar, Peter J.; Broaddus, William C.; Chen, Zhi-jian; Fatouros, Panos P.; Gillies, George T.; Corwin, Frank D.

    2010-06-01

    A common approach to quantify gadolinium (Gd) contrast agents involves measuring the post-contrast change in T1 rate and then using the constant T1 relaxivity R to determine the contrast agent concentration. Because this method is fast and non-invasive, it could be potentially valuable in many areas of brain research. However, to accurately measure contrast agent concentrations in the brain, the T1 relaxivity R of the specific agent must be accurately known. Furthermore, the macromolecular content and compartmentalization of the brain extracellular space (ECS) are expected to significantly alter R from values measured in aqueous solutions. In this study, the T1 relaxivity R of gadolinium-diethylene-triamine penta-acetic acid (Gd-DTPA) was measured following direct interstitial infusions of three different contrast agent concentrations to the parenchyma of rat brains. Changes in magnetic resonance (MR) T1 values were compared to brain slice concentrations determined with inductively coupled plasma atomic emission spectroscopy (ICP-AES) to determine R in 15 rats. Additionally, samples of cerebrospinal fluid, blood and urine were analyzed to evaluate possible Gd-DTPA clearance from the brain. The T1 relaxivity R of Gd-DTPA in the brain ECS was measured to be 5.35 (mM s)-1 in a 2.4 T field. This value is considerably higher than estimations used in studies by other groups. Measurements of brain Gd-DTPA tissue concentrations using MRI and ICP-AES demonstrated a high degree of coincidence. Clearance of Gd-DTPA was minimal at the time point immediately after infusion. These results suggest that the environment of the brain does in fact significantly affect Gd T1 relaxivity, and that MRI can accurately measure contrast agent concentrations when this relaxivity is well characterized.

  16. MRI ductography of contrast agent distribution and leakage in normal mouse mammary ducts and ducts with in situ cancer.

    PubMed

    Markiewicz, Erica; Fan, Xiaobing; Mustafi, Devkumar; Zamora, Marta; Conzen, Suzanne D; Karczmar, Gregory S

    2017-07-01

    High resolution 3D MRI was used to study contrast agent distribution and leakage in normal mouse mammary glands and glands containing in situ cancer after intra-ductal injection. Five female FVB/N mice (~19weeks old) with no detectable mammary cancer and eight C3(1) SV40 Tag virgin female mice (~15weeks old) with extensive in situ cancer were studied. A 34G, 45° tip Hamilton needle with a 25μL Hamilton syringe was inserted into the tip of the nipple and approximately 15μL of a Gadodiamide was injected slowly over 1min into the nipple and throughout the duct on one side of the inguinal gland. Following injection, the mouse was placed in a 9.4T MRI scanner, and a series of high resolution 3D T1-weighted images was acquired with a temporal resolution of 9.1min to follow contrast agent leakage from the ducts. The first image was acquired at about 12min after injection. Ductal enhancement regions detected in images acquired between 12 and 21min after contrast agent injection was five times smaller in SV40 mouse mammary ducts (p<0.001) than in non-cancerous FVB/N mouse mammary ducts, perhaps due to rapid washout of contrast agent from the SV40 ducts. The contrast agent washout rate measured between 12min and 90min after injection was ~20% faster (p<0.004) in SV40 mammary ducts than in FVB/N mammary ducts. These results may be due to higher permeability of the SV40 ducts, likely due to the presence of in situ cancers. Therefore, increased permeability of ducts may indicate early stage breast cancers. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Effects of diatrizoate and iopamidol on spermatogenesis.

    PubMed

    Yaghmai, V; Harapanhalli, R S; Patel, Y D; Baker, S R; Rao, D V

    1993-12-01

    The biological effects of iodinated contrast media were examined by using spermatogenesis in mouse testis as the experimental model. Spermhead survival and abnormality assays were used as the biological end points. Diatrizoate meglumine/diatrizoate sodium and iopamidol were administered intravenously at equal rates and concentrations. Testicular uptake and clearance of these contrast agents were examined by high-performance liquid chromatography techniques. Appropriate mannitol solutions were employed as osmolality controls. Intravenous administration of the contrast agent or its respective mannitol control resulted in approximately a 30% decrease in spermhead count. A dose-related experiment with mannitol demonstrated that the spermhead count decreased rapidly until 600 mOsm/kg was reached, beyond which this decrease was minimal. Clearance of both contrast media was complete in approximately 4 hours. No significant increase in the induction of spermhead abnormalities was observed. Osmotic substances, such as iodinated contrast agents, affect the process of spermatogenesis.

  18. Methylene blue microbubbles as a model dual-modality contrast agent for ultrasound and activatable photoacoustic imaging

    NASA Astrophysics Data System (ADS)

    Jeon, Mansik; Song, Wentao; Huynh, Elizabeth; Kim, Jungho; Kim, Jeesu; Helfield, Brandon L.; Leung, Ben Y. C.; Goertz, David E.; Zheng, Gang; Oh, Jungtaek; Lovell, Jonathan F.; Kim, Chulhong

    2014-01-01

    Ultrasound and photoacoustic imaging are highly complementary modalities since both use ultrasonic detection for operation. Increasingly, photoacoustic and ultrasound have been integrated in terms of hardware instrumentation. To generate a broadly accessible dual-modality contrast agent, we generated microbubbles (a standard ultrasound contrast agent) in a solution of methylene blue (a standard photoacoustic dye). This MB2 solution was formed effectively and was optimized as a dual-modality contrast solution. As microbubble concentration increased (with methylene blue concentration constant), photoacoustic signal was attenuated in the MB2 solution. When methylene blue concentration increased (with microbubble concentration held constant), no ultrasonic interference was observed. Using an MB2 solution that strongly attenuated all photoacoustic signal, high powered ultrasound could be used to burst the microbubbles and dramatically enhance photoacoustic contrast (>800-fold increase), providing a new method for spatiotemporal control of photoacoustic signal generation.

  19. Methylene blue microbubbles as a model dual-modality contrast agent for ultrasound and activatable photoacoustic imaging.

    PubMed

    Jeon, Mansik; Song, Wentao; Huynh, Elizabeth; Kim, Jungho; Kim, Jeesu; Helfield, Brandon L; Leung, Ben Y C; Goertz, David E; Zheng, Gang; Oh, Jungtaek; Lovell, Jonathan F; Kim, Chulhong

    2014-01-01

    Ultrasound and photoacoustic imaging are highly complementary modalities since both use ultrasonic detection for operation. Increasingly, photoacoustic and ultrasound have been integrated in terms of hardware instrumentation. To generate a broadly accessible dual-modality contrast agent, we generated microbubbles (a standard ultrasound contrast agent) in a solution of methylene blue (a standard photoacoustic dye). This MB2 solution was formed effectively and was optimized as a dual-modality contrast solution. As microbubble concentration increased (with methylene blue concentration constant), photoacoustic signal was attenuated in the MB2 solution. When methylene blue concentration increased (with microbubble concentration held constant), no ultrasonic interference was observed. Using an MB2 solution that strongly attenuated all photoacoustic signal, high powered ultrasound could be used to burst the microbubbles and dramatically enhance photoacoustic contrast (>800-fold increase), providing a new method for spatiotemporal control of photoacoustic signal generation.

  20. 3D widefield light microscope image reconstruction without dyes

    NASA Astrophysics Data System (ADS)

    Larkin, S.; Larson, J.; Holmes, C.; Vaicik, M.; Turturro, M.; Jurkevich, A.; Sinha, S.; Ezashi, T.; Papavasiliou, G.; Brey, E.; Holmes, T.

    2015-03-01

    3D image reconstruction using light microscope modalities without exogenous contrast agents is proposed and investigated as an approach to produce 3D images of biological samples for live imaging applications. Multimodality and multispectral imaging, used in concert with this 3D optical sectioning approach is also proposed as a way to further produce contrast that could be specific to components in the sample. The methods avoid usage of contrast agents. Contrast agents, such as fluorescent or absorbing dyes, can be toxic to cells or alter cell behavior. Current modes of producing 3D image sets from a light microscope, such as 3D deconvolution algorithms and confocal microscopy generally require contrast agents. Zernike phase contrast (ZPC), transmitted light brightfield (TLB), darkfield microscopy and others can produce contrast without dyes. Some of these modalities have not previously benefitted from 3D image reconstruction algorithms, however. The 3D image reconstruction algorithm is based on an underlying physical model of scattering potential, expressed as the sample's 3D absorption and phase quantities. The algorithm is based upon optimizing an objective function - the I-divergence - while solving for the 3D absorption and phase quantities. Unlike typical deconvolution algorithms, each microscope modality, such as ZPC or TLB, produces two output image sets instead of one. Contrast in the displayed image and 3D renderings is further enabled by treating the multispectral/multimodal data as a feature set in a mathematical formulation that uses the principal component method of statistics.

  1. Passive microlesion detection and mapping for treatment of hypertrophic cardiomyopathy

    NASA Astrophysics Data System (ADS)

    Zhu, Yiying I.; Miller, Douglas L.; Dou, Chunyan; Kripfgans, Oliver D.

    2017-03-01

    Intermittent high intensity ultrasound pulses with circulating contrast agent microbubbles can induce scattered microlesions of potential value for myocardial reduction therapy. This paper presents an in vitro setup imitating the treatment for monitoring development. A preclinical imaging system with a single element transducer, synchronization and receive-only imaging transducer array has been implemented on a research platform. Contrast agent microbubbles pumped in a dialysis tubing setup were exposed to high intensity focused ultrasound at 1.0/3.5 MHz center frequencies. Polystyrene spheres were employed as linear scatterers compared to contrast agents for system transfer function equalization. A cavitation mapping technique was employed to spatially locate and depict microbubble activity during treatment. For high acoustic pressure amplitudes a 5 dB difference between contrast agent and solid spheres was observed and spatially mapped. The in-plane resolution was 4.5 mm for axial and 1.5 mm laterally. In the future, this cavitation detection scheme will be applied to monitor in vivo microlesioning in real-time.

  2. Introductory Chemistry: A Molar Relaxivity Experiment in the High School Classroom.

    PubMed

    Dawsey, Anna C; Hathaway, Kathryn L; Kim, Susie; Williams, Travis J

    2013-07-09

    Dotarem and Magnevist, two clinically available magnetic resonance imaging (MRI) contrast agents, were assessed in a high school science classroom with respect to which is the better contrast agent. Magnevist, the more efficacious contrast agent, has negative side effects because its gadolinium center can escape from its ligand. However, Dotarem, though a less efficacious contrast agent, is a safer drug choice. After the experiment, students are confronted with the FDA warning on Magnevist, which enabled a discussion of drug efficacy versus safety. We describe a laboratory experiment in which NMR spin lattice relaxation rate measurements are used to quantify the relaxivities of the active ingredients of Dotarem and Magnevist. The spin lattice relaxation rate gives the average amount of time it takes the excited nucleus to relax back to the original state. Students learn by constructing molar relaxivity curves based on inversion recovery data sets that Magnevist is more relaxive than Dotarem. This experiment is suitable for any analytical chemistry laboratory with access to NMR.

  3. Synthesis and in vitro evaluation of bone-seeking superparamagnetic iron oxide nanoparticles as contrast agents for imaging bone metabolic activity.

    PubMed

    Panahifar, Arash; Mahmoudi, Morteza; Doschak, Michael R

    2013-06-12

    In this article, we report the synthesis and in vitro evaluation of a new class of nonionizing bone-targeting contrast agents based on bisphosphonate-conjugated superparamagnetic iron oxide nanoparticles (SPIONs), for use in imaging of bone turnover with magnetic resonance imaging (MRI). Similar to bone-targeting (99m)Technetium medronate, our novel contrast agent uses bisphosphonates to impart bone-seeking properties, but replaces the former radioisotope with nonionizing SPIONs which enables their subsequent detection using MRI. Our reported method is relatively simple, quick and cost-effective and results in BP-SPIONs with a final nanoparticle size of 17 nm under electron microscopy technique (i.e., TEM). In-vitro binding studies of our novel bone tracer have shown selective binding affinity (around 65%) for hydroxyapatite, the principal mineral of bone. Bone-targeting SPIONs offer the potential for use as nonionizing MRI contrast agents capable of imaging dynamic bone turnover, for use in the diagnosis and monitoring of metabolic bone diseases and related bone pathology.

  4. On-chip generation of microbubbles as a practical technology for manufacturing contrast agents for ultrasonic imaging

    PubMed Central

    Hettiarachchi, Kanaka; Talu, Esra; Longo, Marjorie L.; Dayton, Paul A.; Lee, Abraham P.

    2007-01-01

    This paper presents a new manufacturing method to generate monodisperse microbubble contrast agents with polydispersity index (σ) values of <2% through microfluidic flow-focusing. Micron-sized lipid shell-based perfluorocarbon (PFC) gas microbubbles for use as ultrasound contrast agents were produced using this method. The poly(dimethylsiloxane) (PDMS)-based devices feature expanding nozzle geometry with a 7 μm orifice width, and are robust enough for consistent production of microbubbles with runtimes lasting several hours. With high-speed imaging, we characterized relationships between channel geometry, liquid flow rate Q, and gas pressure P in controlling bubble sizes. By a simple optimization of the channel geometry and Q and P, bubbles with a mean diameter of <5 μm can be obtained, ideal for various ultrasonic imaging applications. This method demonstrates the potential of microfluidics as an efficient means for custom-designing ultrasound contrast agents with precise size distributions, different gas compositions and new shell materials for stabilization, and for future targeted imaging and therapeutic applications. PMID:17389962

  5. Photoacoustic imaging at 1064nm wavelength with exogenous contrast agents

    NASA Astrophysics Data System (ADS)

    Upputuri, Paul Kumar; Jiang, Yuyan; Pu, Kanyi; Pramanik, Manojit

    2018-02-01

    Photoacoustic (PA) imaging is a promising imaging modality for both preclinical research and clinical practices. Laser wavelengths in the first near infrared window (NIR-I, 650-950 nm) have been widely used for photoacoustic imaging. As compared with NIR-I window, scattering of photons by biological tissues is largely reduced in the second NIR (NIR-II) window, leading to enhanced imaging fidelity. However, the lack of biocompatible NIR-II absorbing exogenous agents prevented the use of this window for in vivo imaging. In recent years, few studies have been reported on photoacoustic imaging in NIR-II window using exogenous contrast agents. In this work, we discuss the recent work on PA imaging using 1064 nm wavelength, the fundamental of Nd:YAG laser, as an excitation wavelength. The PA imaging at 1064 nm is advantageous because of the low and homogeneous signal from tissue background, enabling high contrast in PA imaging when NIR-II absorbing contrast agents are employed.

  6. [Perioperative adverse events related to antidepressive agents use].

    PubMed

    Rozec, B; Cinotti, R; Blanloeil, Y

    2011-11-01

    Depression is the most common psychiatric disease, which is treated by the use of antidepressive agents possessing various mechanisms of action. Thus, the use in preoperative period of antidepressive agents is frequent (7% of patients scheduled for surgery). The objective of this review was to update the knowledge on the drug interactions between antidepressive agents and drugs used in perioperative period. (i) Medline and Ovid databases using combination of antidepressive agent and perioperative period as keywords; (ii) national and European epidemiologic database; (iii) expert recommendation and official French health agency; (iv) reference book chapters. The clinical practice showed a limited risk of adverse event related to antidepressant agents interaction with perioperative used drugs. In the two past decades, few relevant observations of adverse event related with imipramine and monoamine oxidase inhibitors use was reported. The most recent antidepressive agents had no serious adverse interaction. Nevertheless, the serotonin syndrome has to be known as far as it is more and more reported. In case of hypotension, the use of vasopressive agent has to be careful because of excessive response. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  7. Tunable Semiconducting Polymer Nanoparticles with INDT-Based Conjugated Polymers for Photoacoustic Molecular Imaging.

    PubMed

    Stahl, Thomas; Bofinger, Robin; Lam, Ivan; Fallon, Kealan J; Johnson, Peter; Ogunlade, Olumide; Vassileva, Vessela; Pedley, R Barbara; Beard, Paul C; Hailes, Helen C; Bronstein, Hugo; Tabor, Alethea B

    2017-06-21

    Photoacoustic imaging combines both excellent spatial resolution with high contrast and specificity, without the need for patients to be exposed to ionizing radiation. This makes it ideal for the study of physiological changes occurring during tumorigenesis and cardiovascular disease. In order to fully exploit the potential of this technique, new exogenous contrast agents with strong absorbance in the near-infrared range, good stability and biocompatibility, are required. In this paper, we report the formulation and characterization of a novel series of endogenous contrast agents for photoacoustic imaging in vivo. These contrast agents are based on a recently reported series of indigoid π-conjugated organic semiconductors, coformulated with 1,2-dipalmitoyl-sn-glycero-3-phosphocholine, to give semiconducting polymer nanoparticles of about 150 nm diameter. These nanoparticles exhibited excellent absorption in the near-infrared region, with good photoacoustic signal generation efficiencies, high photostability, and extinction coefficients of up to three times higher than those previously reported. The absorption maximum is conveniently located in the spectral region of low absorption of chromophores within human tissue. Using the most promising semiconducting polymer nanoparticle, we have demonstrated wavelength-dependent differential contrast between vasculature and the nanoparticles, which can be used to unambiguously discriminate the presence of the contrast agent in vivo.

  8. ACOUSTIC CHARACTERIZATION AND PHARAMACOKINETIC ANALYSES OF NEW NANOBUBBLE ULTRASOUND CONTRAST AGENTS

    PubMed Central

    Wu, Hanping; Rognin, Nicolas G.; Krupka, Tianyi M.; Solorio, Luis; Yoshiara, Hiroki; Guenette, Gilles; Sanders, Christoher; Kamiyama, Naohisa; Exner, Agata A.

    2013-01-01

    In contrast to the clinically used microbubble ultrasound contrast agents, nanoscale bubbles (or nanobubbles) may potentially extravasate into tumors that exhibit more permeable vasculature, facilitating targeted molecular imaging and drug delivery. Our group recently presented a simple strategy using the non-ionic surfactant Pluronic as a size control excipient to produce nanobubbles with a mean diameter of 200 nm that exhibited stability and echogenicity on par with microbubbles. The objective of this study was to carry out an in-depth characterization of nanobubble properties as compared with Definity microbubbles, both in vitro and in vivo. Through use of a tissue-mimicking phantom, in vitro experiments measured the echogenicity of the contrast agent solutions and the contrast agent dissolution rate over time. Nanobubbles were found to be more echogenic than Definity microbubbles at three different harmonic frequencies (8, 6.2 and 3.5 MHz). Definity microbubbles also dissolved 1.67 times faster than nanobubbles. Pharmacokinetic studies were then performed in vivo in a subcutaneous human colorectal adenocarcinoma (LS174T) in mice. The peak enhancement and decay rates of contrast agents after bolus injection in the liver, kidney and tumor were analyzed. No significant differences were observed in peak enhancement between the nanobubble and Definity groups in the three tested regions (tumor, liver and kidney). However, the decay rates of nanobubbles in tumor and kidney were significantly slower than those of Definity in the first 200-s fast initial phase. There were no significant differences in the decay rate in the liver in the initial phase or in three regions of interest in the terminal phase. Our results suggest that the stability and acoustic properties of the new nanobubble contrast agents are superior to those of the clinically used Definity microbubbles. The slower washout of nanobubbles in tumors suggests potential entrapment of the bubbles within the tumor parenchyma. PMID:23932272

  9. Acoustic characterization and pharmacokinetic analyses of new nanobubble ultrasound contrast agents.

    PubMed

    Wu, Hanping; Rognin, Nicolas G; Krupka, Tianyi M; Solorio, Luis; Yoshiara, Hiroki; Guenette, Gilles; Sanders, Christopher; Kamiyama, Naohisa; Exner, Agata A

    2013-11-01

    In contrast to the clinically used microbubble ultrasound contrast agents, nanoscale bubbles (or nanobubbles) may potentially extravasate into tumors that exhibit more permeable vasculature, facilitating targeted molecular imaging and drug delivery. Our group recently presented a simple strategy using the non-ionic surfactant Pluronic as a size control excipient to produce nanobubbles with a mean diameter of 200 nm that exhibited stability and echogenicity on par with microbubbles. The objective of this study was to carry out an in-depth characterization of nanobubble properties as compared with Definity microbubbles, both in vitro and in vivo. Through use of a tissue-mimicking phantom, in vitro experiments measured the echogenicity of the contrast agent solutions and the contrast agent dissolution rate over time. Nanobubbles were found to be more echogenic than Definity microbubbles at three different harmonic frequencies (8, 6.2 and 3.5 MHz). Definity microbubbles also dissolved 1.67 times faster than nanobubbles. Pharmacokinetic studies were then performed in vivo in a subcutaneous human colorectal adenocarcinoma (LS174T) in mice. The peak enhancement and decay rates of contrast agents after bolus injection in the liver, kidney and tumor were analyzed. No significant differences were observed in peak enhancement between the nanobubble and Definity groups in the three tested regions (tumor, liver and kidney). However, the decay rates of nanobubbles in tumor and kidney were significantly slower than those of Definity in the first 200-s fast initial phase. There were no significant differences in the decay rates in the liver in the initial phase or in three regions of interest in the terminal phase. Our results suggest that the stability and acoustic properties of the new nanobubble contrast agents are superior to those of the clinically used Definity microbubbles. The slower washout of nanobubbles in tumors suggests potential entrapment of the bubbles within the tumor parenchyma. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  10. Demonstration of a bronchobiliary fistula using magnetic resonance image with hepatospecific contrast agent.

    PubMed

    Baleato-González, S; Vieira-Leite, C; Alvárez-Castro, A M; García-Figueiras, R

    Bronchobiliary fistulas are a rare entity of difficult diagnosis. The utility of magnetic resonance image (MRI) with hepatospecific contrast agents to demonstrate such condition is seldom described in the literature. This case reports a patient with pulmonary infection with a past history of hepatic surgery for hydatid disease in whom the presence of bile in the sputum rose the suspicious of a bronchobiliary fistula. MRI with hepatospecific contrast agents showed the communication between the biliary and bronchial tree and provided anatomic data to allow a therapeutic approach. Copyright © 2017 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Stability analysis of ultrasound thick-shell contrast agents.

    PubMed

    Lu, Xiaozhen; Chahine, Georges L; Hsiao, Chao-Tsung

    2012-01-01

    The stability of thick shell encapsulated bubbles is studied analytically. 3-D small perturbations are introduced to the spherical oscillations of a contrast agent bubble in response to a sinusoidal acoustic field with different amplitudes of excitation. The equations of the perturbation amplitudes are derived using asymptotic expansions and linear stability analysis is then applied to the resulting differential equations. The stability of the encapsulated microbubbles to nonspherical small perturbations is examined by solving an eigenvalue problem. The approach then identifies the fastest growing perturbations which could lead to the breakup of the encapsulated microbubble or contrast agent. © 2012 Acoustical Society of America.

  12. Studies of MRI relaxivities of gadolinium-labeled dendrons

    NASA Astrophysics Data System (ADS)

    Pan, Hongmu; Daniel, Marie-Christine

    2011-05-01

    In cancer detection, imaging techniques have a great importance in early diagnosis. The more sensitive the imaging technique and the earlier the tumor can be detected. Contrast agents have the capability to increase the sensitivity in imaging techniques such as magnetic resonance imaging (MRI). Until now, gadolinium-based contrast agents are mainly used for MRI, and show good enhancement. But improvement is needed for detection of smaller tumors at the earliest stage possible. The dendrons complexed with Gd(DOTA) were synthesized and evaluated as a new MRI contrast agent. The longitudinal and transverse relaxation effects were tested and compared with commercial drug Magnevist, Gd(DTPA).

  13. In vivo detection of cucurbit[6]uril, a hyperpolarized xenon contrast agent for a xenon magnetic resonance imaging biosensor

    PubMed Central

    Hane, Francis T.; Li, Tao; Smylie, Peter; Pellizzari, Raiili M.; Plata, Jennifer A.; DeBoef, Brenton; Albert, Mitchell S.

    2017-01-01

    The Hyperpolarized gas Chemical Exchange Saturation Transfer (HyperCEST) Magnetic Resonance (MR) technique has the potential to increase the sensitivity of a hyperpolarized xenon-129 MRI contrast agent. Signal enhancement is accomplished by selectively depolarizing the xenon within a cage molecule which, upon exchange, reduces the signal in the dissolved phase pool. Herein we demonstrate the in vivo detection of the cucurbit[6]uril (CB6) contrast agent within the vasculature of a living rat. Our work may be used as a stepping stone towards using the HyperCEST technique as a molecular imaging modality. PMID:28106110

  14. Hydroxy double salts intercalated with Mn(II) complexes as potential contrast agents

    NASA Astrophysics Data System (ADS)

    Jin, Miao; Li, Wanjing; Spillane, Dominic E. M.; Geraldes, Carlos F. G. C.; Williams, Gareth R.; Bligh, S. W. Annie

    2016-03-01

    A series of Mn(II) aminophosphonate complexes were successfully synthesized and intercalated into the hydroxy double salt [Zn5(OH)8]Cl2·yH2O. Complex incorporation led to an increase in the interlayer spacing from 7.8 to 10-12 Å. Infrared spectroscopy showed the presence of the characteristic vibration peaks of the Mn(II) complexes in the intercalates' spectra, indicating successful incorporation. The complex-loaded composites had somewhat lower proton relaxivities than the pure complexes. Nevertheless, these intercalates may have use as MRI contrast agents for patients with poor kidney function, where traditional Gd(III)-based contrast agents cause severe renal failure.

  15. Magnetic resonance angiography: current status and future directions

    PubMed Central

    2011-01-01

    With recent improvement in hardware and software techniques, magnetic resonance angiography (MRA) has undergone significant changes in technique and approach. The advent of 3.0 T magnets has allowed reduction in exogenous contrast dose without compromising overall image quality. The use of novel intravascular contrast agents substantially increases the image windows and decreases contrast dose. Additionally, the lower risk and cost in non-contrast enhanced (NCE) MRA has sparked renewed interest in these methods. This article discusses the current state of both contrast-enhanced (CE) and NCE-MRA. New CE-MRA methods take advantage of dose reduction at 3.0 T, novel contrast agents, and parallel imaging methods. The risks of gadolinium-based contrast media, and the NCE-MRA methods of time-of-flight, steady-state free precession, and phase contrast are discussed. PMID:21388544

  16. Landscape features, standards, and semantics in U.S. national topographic mapping databases

    USGS Publications Warehouse

    Varanka, Dalia

    2009-01-01

    The objective of this paper is to examine the contrast between local, field-surveyed topographical representation and feature representation in digital, centralized databases and to clarify their ontological implications. The semantics of these two approaches are contrasted by examining the categorization of features by subject domains inherent to national topographic mapping. When comparing five USGS topographic mapping domain and feature lists, results indicate that multiple semantic meanings and ontology rules were applied to the initial digital database, but were lost as databases became more centralized at national scales, and common semantics were replaced by technological terms.

  17. Microenvironment-Sensitive Multimodal Contrast Agent for Prostate Cancer Diagnosis

    DTIC Science & Technology

    2014-10-01

    which serve as a contrast agent for Magnetic Resonance Imaging (MRI), coated with a biopolymer (i.e. starch ) to improve biocompatibility, and...size stability (i.e. resisted aggregation) and lower protein binding than the unmodified MNP. The MNPs were also incubated for varying time periods with

  18. Effects of ultrasound and ultrasound contrast agent on vascular tissue

    PubMed Central

    2012-01-01

    Background Ultrasound (US) imaging can be enhanced using gas-filled microbubble contrast agents. Strong echo signals are induced at the tissue-gas interface following microbubble collapse. Applications include assessment of ventricular function and virtual histology. Aim While ultrasound and US contrast agents are widely used, their impact on the physiological response of vascular tissue to vasoactive agents has not been investigated in detail. Methods and results In the present study, rat dorsal aortas were treated with US via a clinical imaging transducer in the presence or absence of the US contrast agent, Optison. Aortas treated with both US and Optison were unable to contract in response to phenylephrine or to relax in the presence of acetylcholine. Histology of the arteries was unremarkable. When the treated aortas were stained for endothelial markers, a distinct loss of endothelium was observed. Importantly, terminal deoxynucleotidyl transferase mediated dUTP nick-end-labeling (TUNEL) staining of treated aortas demonstrated incipient apoptosis in the endothelium. Conclusions Taken together, these ex vivo results suggest that the combination of US and Optison may alter arterial integrity and promote vascular injury; however, the in vivo interaction of Optison and ultrasound remains an open question. PMID:22805356

  19. An albumin-based gold nanocomposites as potential dual mode CT/MRI contrast agent

    NASA Astrophysics Data System (ADS)

    Zhao, Wenjing; Chen, Lina; Wang, Zhiming; Huang, Yuankui; Jia, Nengqin

    2018-02-01

    In pursuit of the biological detection applications, recent years have witnessed the prosperity of novel multi-modal nanoprobes. In this study, biocompatible bovine serum albumin (BSA)-coated gold nanoparticles (Au NPs) containing Gd (III) as the contrast agent for both X-ray CT and T1-weighted MR imaging is reported. Firstly, the Au NPs with BSA coating (Au@BSA) was prepared through a moderate one-pot reduction route in the presence of hydrazine hydrate as reducer. Sequentially, the BSA coating enables modification of diethylenetriaminepentaacetic acid (DTPA) as well as targeting reagent hyaluronic acid (HA), and further chelation of Gd (III) ions led to the formation of biomimetic nanoagent HA-targeted Gd-Au NPs (HA-targeted Au@BSA-Gd-DTPA). Several techniques were used to thoroughly characterize the formed HA-targeted Gd-Au NPs. As expected, the as-prepared nanoagent with mean diameter of 13.82 nm exhibits not only good colloid stablility and water dispersibility, but also satisfying low cytotoxicity and hemocompatibility in the tested concentration range. Additionally, for the CT phantoms, the obtained nanocomplex shows an improved contrast in CT scanning than that of Au@BSA as well as small molecule iodine-based CT contrast agents such as iopromide. Meanwhile, for the T1-weighted MRI images, there is a linear increase of contrast with concentration of Gd for the two cases of HA-targeted Gd-Au NPs and Magnevist. Strikingly, the nanoagent we explored displays a relatively higher r1 relaxivity than that of commercial MR contrast agents. Therefore, this newly constructed nanoagent could be used as contrast agents for synergistically enhanced X-ray CT and MR phantoms, holding promising potential for future biomedical applications.

  20. Comparison of transducers with different frequencies in breast contrast-enhanced ultrasound (CEUS) using SonoVue as contrast agent.

    PubMed

    Wang, Yong-Mei; Fan, Wei; Zhang, Kai; Zhang, Li; Tan, Zhen; Ma, Rong

    2016-07-01

    To explore the effectiveness of different transducers in breast contrast-enhanced ultrasound (CEUS) using SonoVue(®) (Bracco, Plan-Les-Ouates, Switzerland) as the contrast agent. Breast CEUS was performed in 51 patients with 51 breast lesions using a low-frequency transducer (probe C5-1) and a high-frequency transducer (probe L12-5) separately. All image processes were reviewed for the presence of local blood perfusion defects and surrounding vessels. McNemar's test was conducted to compare the detection effectiveness between these two transducers. Pathological results revealed 38 malignant and 13 benign lesions. The two transducers showed no difference in detecting benign lesions. Among malignant lesions, CEUS conducted by probe C5-1 (frequency range from 1 to 5 MHz) presented 23 (60.5%) lesions with local blood perfusion defects and 26 (68.4%) lesions with surrounding vessels. Meanwhile, probe L12-5 (frequency range from 5 to 12 MHz) showed only 12 (31.6%) lesions with local blood perfusion defects and 12 (31.6%) lesions with surrounding vessel. Probe C5-1 was more sensitive than probe L12-5 in detecting malignant CEUS characteristics (p-value < 0.05). The low-frequency transducer was more sensitive than the high-frequency transducer in breast CEUS using SonoVue as the contrast agent. A new contrast agent with a higher resonance frequency, specially designed for high-frequency transducers, may be helpful in improving the clinical value of breast CEUS. The first study comparing different frequency transducers in breast CEUS of the same patient lesions. We brought out the requirement for CEUS contrast agents which are more suitable for high-frequency examinations.

  1. Transthoracic contrast echocardiography using vitamin B6 and sodium bicarbonate as contrast agents for the diagnosis of patent foramen ovale.

    PubMed

    He, Jiang-Chun; Zheng, Jian-Yong; Li, Xin; Yang, Ye; Zhang, Bo-Yang; Chen, Yu; Li, Xian-Feng; Liu, Ying-Ming; Cao, Yi; Zhao, Li; Li, Tian-Chang

    2017-08-01

    To evaluate the utility of transthoracic contrast echocardiography (cTTE) using vitamin B6 and sodium bicarbonate as contrast agents for diagnosing right-to-left shunt (RLS) caused by patent foramen ovale (PFO) compared to that of transesophageal echocardiography (TEE). We investigated 125 patients admitted to our neurology department with unexplained cerebral infarction and migraine. All patients underwent cTTE using vitamin B6 and sodium bicarbonate as contrast agents, after which they underwent transthoracic echocardiography. The Doppler signal was recorded during the Valsalva maneuver, and TEE examinations were performed. The feasibility, diagnostic sensitivity, and safety of cTTE and TEE for PFO recognition were compared. Evidence of PFO was found in 49 (39.20%) patients with cTTE, more than were detected with TEE (39, 31.20%) (χ 2 =5.0625, P=0.0244). cTTE had a sensitivity of 92.31% and a specificity of 84.88% for diagnosing PFO, showing high concordance with TEE for PFO recognition (κ=0.72). Further, results of a semi-quantitative evaluation of PFO-RLS by cTTE were better than those with TEE (Z=-2.011, P=0.044). No significant adverse reaction was discovered during cTTE examination. cTTE using vitamin B6 and sodium bicarbonate as contrast agents has relatively good sensitivity and specificity for diagnosing RLS caused by PFO when compared with those for TEE. Using vitamin B6 and sodium bicarbonate as contrast agents to perform cTTE is recommended for detecting and diagnosing the PFO due to its simplicity, non-invasive character, low cost, and high feasibility.

  2. MRI contrast agent for targeting glioma: interleukin-13 labeled liposome encapsulating gadolinium-DTPA

    PubMed Central

    Liu, Xiaoli; Madhankumar, Achuthamangalam B.; Miller, Patti A.; Duck, Kari A.; Hafenstein, Susan; Rizk, Elias; Slagle-Webb, Becky; Sheehan, Jonas M.; Connor, James R.; Yang, Qing X.

    2016-01-01

    Background Detection of glioma with MRI contrast agent is limited to cases in which the blood-brain barrier (BBB) is compromised as contrast agents cannot cross the BBB. Thus, an early-stage infiltrating tumor is not detectable. Interleukin-13 receptor alpha 2 (IL-13Rα2), which has been shown to be overexpressed in glioma, can be used as a target moiety. We hypothesized that liposomes conjugated with IL-13 and encapsulating MRI contrast agent are capable of passing through an intact BBB and producing MRI contrast with greater sensitivity. Methods The targeted MRI contrast agent was created by encapsulating Magnevist (Gd-DTPA) into liposomes conjugated with IL-13 and characterized by particle size distribution, cytotoxicity, and MRI relaxivity. MR image intensity was evaluated in the brain in normal mice post injection of Gd-DTPA and IL-13-liposome-Gd-DTPA one day apart. The specificity for glioma detection by IL-13-liposome-Gd-DTPA was demonstrated in an intracranial glioma mouse model and validated histologically. Results The average size of IL-13-liposome-Gd-DTPA was 137 ± 43 nm with relaxivity of 4.0 ± 0.4 L/mmole-s at 7 Tesla. No significant cytotoxicity was observed with MTS assay and serum chemistry in mice. The MRI signal intensity was enhanced up to 15% post injection of IL-13-liposome-Gd-DTPA in normal brain tissue following a similar time course as that for the pituitary gland outside of the BBB. MRI enhanced by IL-13-liposome-Gd-DTPA detected small tumor masses in addition to those seen with Magnevist-enhanced MRI. Conclusions IL-13-liposome-Gd-DTPA is able to pass through the uncompromised BBB and detect an early stage glioma that cannot be seen with conventional contrast-enhanced MRI. PMID:26519740

  3. Ultrasound imaging beyond the vasculature with new generation contrast agents.

    PubMed

    Perera, Reshani H; Hernandez, Christopher; Zhou, Haoyan; Kota, Pavan; Burke, Alan; Exner, Agata A

    2015-01-01

    Current commercially available ultrasound contrast agents are gas-filled, lipid- or protein-stabilized microbubbles larger than 1 µm in diameter. Because the signal generated by these agents is highly dependent on their size, small yet highly echogenic particles have been historically difficult to produce. This has limited the molecular imaging applications of ultrasound to the blood pool. In the area of cancer imaging, microbubble applications have been constrained to imaging molecular signatures of tumor vasculature and drug delivery enabled by ultrasound-modulated bubble destruction. Recently, with the rise of sophisticated advancements in nanomedicine, ultrasound contrast agents, which are an order of magnitude smaller (100-500 nm) than their currently utilized counterparts, have been undergoing rapid development. These agents are poised to greatly expand the capabilities of ultrasound in the field of targeted cancer detection and therapy by taking advantage of the enhanced permeability and retention phenomenon of many tumors and can extravasate beyond the leaky tumor vasculature. Agent extravasation facilitates highly sensitive detection of cell surface or microenvironment biomarkers, which could advance early cancer detection. Likewise, when combined with appropriate therapeutic agents and ultrasound-mediated deployment on demand, directly at the tumor site, these nanoparticles have been shown to contribute to improved therapeutic outcomes. Ultrasound's safety profile, broad accessibility and relatively low cost make it an ideal modality for the changing face of healthcare today. Aided by the multifaceted nano-sized contrast agents and targeted theranostic moieties described herein, ultrasound can considerably broaden its reach in future applications focused on the diagnosis and staging of cancer. © 2015 Wiley Periodicals, Inc.

  4. Ultrasound Imaging Beyond the Vasculature with New Generation Contrast Agents

    PubMed Central

    Perera, Reshani H.; Hernandez, Christopher; Zhou, Haoyan; Kota, Pavan; Burke, Alan

    2015-01-01

    Current commercially available ultrasound contrast agents are gas-filled, lipid- or protein-stabilized microbubbles larger than 1 μm in diameter. Because the signal generated by these agents is highly dependent on their size, small yet highly echogenic particles have been historically difficult to produce. This has limited the molecular imaging applications of ultrasound to the blood pool. In the area of cancer imaging, microbubble applications have been constrained to imaging molecular signatures of tumor vasculature and drug delivery enabled by ultrasound-modulated bubble destruction. Recently, with the rise of sophisticated advancements in nanomedicine, ultrasound contrast agents, which are an order of magnitude smaller (100-500 nm) than their currently utilized counterparts, have been undergoing rapid development. These agents are poised to greatly expand the capabilities of ultrasound in the field of targeted cancer detection and therapy by taking advantage of the enhanced permeability and retention phenomenon of many tumors and can extravasate beyond the leaky tumor vasculature. Agent extravasation facilitates highly sensitive detection of cell surface or microenvironment biomarkers, which could advance early cancer detection. Likewise, when combined with appropriate therapeutic agents and ultrasound-mediated deployment on demand, directly at the tumor site, these nanoparticles have been shown to contribute to improved therapeutic outcomes. Ultrasound's safety profile, broad accessibility and relatively low cost make it an ideal modality for the changing face of healthcare today. Aided by the multifaceted nano-sized contrast agents and targeted theranostic moieties described herein, ultrasound can considerably broaden its reach in future applications focused on the diagnosis and staging of cancer. PMID:25580914

  5. A biomarker-responsive T2ex MRI contrast agent.

    PubMed

    Daryaei, Iman; Randtke, Edward A; Pagel, Mark D

    2017-04-01

    This study investigated a fundamentally new type of responsive MRI contrast agent for molecular imaging that alters T 2 exchange (T 2ex ) properties after interacting with a molecular biomarker. The contrast agent Tm-DO3A-oAA was treated with nitric oxide (NO) and O 2 . The R 1 and R 2 relaxation rates of the reactant and product were measured with respect to concentration, temperature, and pH. Chemical exchange saturation transfer (CEST) spectra of the reactant and product were acquired using a 7 Tesla (T) MRI scanner and analyzed to estimate the chemical exchange rates and r 2ex relaxivities. The reaction of Tm-DO3A-oAA with NO and O 2 caused a 6.4-fold increase in the r 2 relaxivity of the agent, whereas r 1 relaxivity remained unchanged, which demonstrated that Tm-DO3A-oAA is a responsive T 2ex agent. The effects of pH and temperature on the r 2 relaxivities of the reactant and product supported the conclusion that the product's benzimidazole ligand caused the agent to have a fast chemical exchange rate relative to the slow exchange rate of the reactant's ortho-aminoanilide ligand. T 2ex MRI contrast agents are a new type of responsive agent that have good detection sensitivity and specificity for detecting a biomarker, which can serve as a new tool for molecular imaging. Magn Reson Med 77:1665-1670, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  6. On the interplay of shell structure with low- and high-frequency mechanics of multifunctional magnetic microbubbles.

    PubMed

    Poehlmann, Melanie; Grishenkov, Dmitry; Kothapalli, Satya V V N; Härmark, Johan; Hebert, Hans; Philipp, Alexandra; Hoeller, Roland; Seuss, Maximilian; Kuttner, Christian; Margheritelli, Silvia; Paradossi, Gaio; Fery, Andreas

    2014-01-07

    Polymer-shelled magnetic microbubbles have great potential as hybrid contrast agents for ultrasound and magnetic resonance imaging. In this work, we studied US/MRI contrast agents based on air-filled poly(vinyl alcohol)-shelled microbubbles combined with superparamagnetic iron oxide nanoparticles (SPIONs). The SPIONs are integrated either physically or chemically into the polymeric shell of the microbubbles (MBs). As a result, two different designs of a hybrid contrast agent are obtained. With the physical approach, SPIONs are embedded inside the polymeric shell and with the chemical approach SPIONs are covalently linked to the shell surface. The structural design of hybrid probes is important, because it strongly determines the contrast agent's response in the considered imaging methods. In particular, we were interested how structural differences affect the shell's mechanical properties, which play a key role for the MBs' US imaging performance. Therefore, we thoroughly characterized the MBs' geometric features and investigated low-frequency mechanics by using atomic force microscopy (AFM) and high-frequency mechanics by using acoustic tests. Thus, we were able to quantify the impact of the used SPIONs integration method on the shell's elastic modulus, shear modulus and shear viscosity. In summary, the suggested approach contributes to an improved understanding of structure-property relations in US-active hybrid contrast agents and thus provides the basis for their sustainable development and optimization.

  7. Poly(acrylic acid) Bridged Gadolinium Metal-Organic Framework-Gold Nanoparticle Composites as Contrast Agents for Computed Tomography and Magnetic Resonance Bimodal Imaging.

    PubMed

    Tian, Chixia; Zhu, Liping; Lin, Feng; Boyes, Stephen G

    2015-08-19

    Imaging contrast agents for magnetic resonance imaging (MRI) and computed tomography (CT) have received significant attention in the development of techniques for early stage cancer diagnosis. Gadolinium (Gd)(III), which has seven unpaired electrons and a large magnetic moment, can dramatically influence the water proton relaxation and hence exhibits excellent MRI contrast. On the other hand, gold (Au), which has a high atomic number and high X-ray attenuation coefficient, is an ideal contrast agent candidate for X-ray-based CT imaging. Gd metal-organic framework (MOF) nanoparticles with tunable size, high Gd(III) loading and multivalency can potentially overcome the limitations of clinically utilized Gd chelate contrast agents. In this work, we report for the first time the integration of GdMOF nanoparticles with gold nanoparticles (AuNPs) for the preparation of a MRI/CT bimodal imaging agent. Highly stable hybrid GdMOF/AuNPs composites have been prepared by using poly(acrylic acid) as a bridge between the GdMOF nanoparticles and AuNPs. The hybrid nanocomposites were then evaluated in MRI and CT imaging. The results revealed high longitudinal relaxivity in MRI and excellent CT imaging performance. Therefore, these GdMOF/AuNPs hybrid nanocomposites potentially provide a new platform for the development of multimodal imaging probes.

  8. Poly(acrylic acid) Bridged Gadolinium Metal-Organic Framework-Gold Nanoparticle Composites as Contrast Agents for Computed Tomography and Magnetic Resonance Bimodal Imaging

    PubMed Central

    Tian, Chixia; Zhu, Liping; Lin, Feng; Boyes, Stephen G.

    2015-01-01

    Imaging contrast agents for magnetic resonance imaging (MRI) and computed tomography (CT) have received significant attention in the development of techniques for early-stage cancer diagnosis. Gadolinium (Gd) (III), which has seven unpaired electrons and a large magnetic moment, can dramatically influence the water proton relaxation and hence exhibits excellent MRI contrast. On the other hand, gold (Au), which has a high atomic number and high x-ray attenuation coefficient, is an ideal contrast agent candidate for x-ray based CT imaging. Gd metal organic framework (MOF) nanoparticles with tunable size, high Gd (III) loading and multivalency can potentially overcome the limitations of clinically utilized Gd chelate contrast agents. In this work, we report for the first time the integration of GdMOF nanoparticles with gold nanoparticles (AuNPs) for the preparation of a MRI/CT bimodal imaging agent. Highly stable hybrid GdMOF/AuNPs composites have been prepared by using poly(acrylic acid) as a bridge between the GdMOF nanoparticles and AuNPs. The hybrid nanocomposites were then evaluated in MRI and CT imaging. The results revealed high longitudinal relaxivity in MRI and excellent CT imaging performance. Therefore, these GdMOF/AuNPs hybrid nanocomposites potentially provide a new platform for the development of multi-modal imaging probes. PMID:26147906

  9. Counterbalancing the use of ultrasound contrast agents by a cavitation-regulated system.

    PubMed

    Desjouy, C; Fouqueray, M; Lo, C W; Muleki Seya, P; Lee, J L; Bera, J C; Chen, W S; Inserra, C

    2015-09-01

    The stochastic behavior of cavitation can lead to major problems of initiation and maintenance of cavitation during sonication, responsible of poor reproducibility of US-induced bioeffects in the context of sonoporation for instance. To overcome these disadvantages, the injection of ultrasound contrast agents as cavitation nuclei ensures fast initiation and lower acoustic intensities required for cavitation activity. More recently, regulated-cavitation devices based on the real-time modulation of the applied acoustic intensity have shown their potential to maintain a stable cavitation state during an ultrasonic shot, in continuous or pulsed wave conditions. In this paper is investigated the interest, in terms of cavitation activity, of using such regulated-cavitation device or injecting ultrasound contrast agents in the sonicated medium. When using fixed applied acoustic intensity, results showed that introducing ultrasound contrast agents increases reproducibility of cavitation activity (coefficient of variation 62% and 22% without and with UCA, respectively). Moreover, the use of the regulated-cavitation device ensures a given cavitation activity (coefficient of variation less 0.4% in presence of UCAs or not). This highlights the interest of controlling cavitation over time to free cavitation-based application from the use of UCAs. Interestingly, during a one minute sonication, while ultrasound contrast agents progressively disappear, the regulated-cavitation device counterbalance their destruction to sustain a stable inertial cavitation activity. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Contrast media extravasations in patients undergoing computerized tomography scanning: a systematic review and meta-analysis of risk factors and interventions.

    PubMed

    Ding, Sandrine; Meystre, Nicole Richli; Campeanu, Cosmin; Gullo, Giuseppe

    2018-01-01

    To identify risk factors and interventions preventing or reducing contrast medium extravasation. Computed tomography (CT) is a radiological examination essential for the diagnosis and monitoring of many diseases. It is often performed with the intravenous (IV) injection of contrast agents. Use of these products can result in a significant complication, extravasation, which is the accidental leakage of IV material into the surrounding tissue. Patients may feel a sharp pain and skin ulceration or necrosis may develop. This review considered studies that included patients (adults and children) undergoing a CT with IV administration of contrast media. The risk factors considered were patient demographics, comorbidities and medication history. This review also investigated any strategies related to: contrast agent, injection per se, material used for injection, apparatus used, healthcare professionals involved, and patient risk assessment performed by the radiology personnel. The comparators were other interventions or usual care. This review investigated randomized controlled trials and non-randomized controlled trials. When neither of these were available, other study designs, such as prospective and retrospective cohort studies, case-control studies and case series, were considered for inclusion. Primary outcomes considered were: extravasation frequency, volume, severity and complications. The databases PubMed, CINAHL, Embase, the Cochrane Register of Controlled Trials, Web of Science PsycINFO, ProQuest Dissertations and Theses A&I, TRIP Database and ClinicalTrials.gov were searched to find both published and unpublished studies from 1980 to September 2016. Papers were assessed by two independent reviewers for methodological validity using the Joanna Briggs Institute System for the Unified Management, Assessment and Review of Information (JBI SUMARI). Data were extracted using the standardized data extraction tool from JBI SUMARI. In one case, quantitative data from two cohort studies were pooled in a statistical meta-analysis. However, generally, statistical pooling was not possible due to heterogeneity of the interventions, populations of interest or outcomes. Accordingly, the findings have been presented in narrative form. Fifteen articles were selected from a total of 2151 unique studies identified. Two were randomized controlled trials and 13 were quasi-experimental and observational studies. The quality of these studies was judged to be low to moderate. Some patient characteristics, such as female sex and inpatient status, appeared to be risk factors for extravasation. Additionally, injection rate, venous access site and catheter dwelling time could affect the volume extravasated. Preliminary studies seemed to indicate the potential of extravasation detection accessories to identify extravasation and reduce the volume extravasated. The other interventions either did not result in significant reduction in the frequency/volume of extravasation, or the results were mixed across the studies. The majority of the studies included in this review evaluated the outcomes of extravasation frequency and volume. Given the quality of the primary studies, this systematic review identified only potential risk factors and interventions. It further highlighted the research gap in this area and the importance of conducting trials with solid methodological designs.

  11. Molecular Imaging of Tumors Using a Quantitative T1 Mapping Technique via Magnetic Resonance Imaging

    PubMed Central

    Herrmann, Kelsey; Johansen, Mette L.; Craig, Sonya E.; Vincent, Jason; Howell, Michael; Gao, Ying; Lu, Lan; Erokwu, Bernadette; Agnes, Richard S.; Lu, Zheng-Rong; Pokorski, Jonathan K.; Basilion, James; Gulani, Vikas; Griswold, Mark; Flask, Chris; Brady-Kalnay, Susann M.

    2015-01-01

    Magnetic resonance imaging (MRI) of glioblastoma multiforme (GBM) with molecular imaging agents would allow for the specific localization of brain tumors. Prior studies using T1-weighted MR imaging demonstrated that the SBK2-Tris-(Gd-DOTA)3 molecular imaging agent labeled heterotopic xenograft models of brain tumors more intensely than non-specific contrast agents using conventional T1-weighted imaging techniques. In this study, we used a dynamic quantitative T1 mapping strategy to more objectively compare intra-tumoral retention of the SBK2-Tris-(Gd-DOTA)3 agent over time in comparison to non-targeted control agents. Our results demonstrate that the targeted SBK2-Tris-(Gd-DOTA)3 agent, a scrambled-Tris-(Gd-DOTA)3 control agent, and the non-specific clinical contrast agent Optimark™ all enhanced flank tumors of human glioma cells with similar maximal changes on T1 mapping. However, the retention of the agents differs. The non-specific agents show significant recovery within 20 min by an increase in T1 while the specific agent SBK2-Tris-(Gd-DOTA)3 is retained in the tumors and shows little recovery over 60 min. The retention effect is demonstrated by percent change in T1 values and slope calculations as well as by calculations of gadolinium concentration in tumor compared to muscle. Quantitative T1 mapping demonstrates the superior binding and retention in tumors of the SBK2-Tris-(Gd-DOTA)3 agent over time compared to the non-specific contrast agent currently in clinical use. PMID:26435847

  12. Carboxymethyl cellulose (CMC)-loaded Co-Cu doped manganese ferrite nanorods as a new dual-modal simultaneous contrast agent for magnetic resonance imaging and nanocarrier for drug delivery system

    NASA Astrophysics Data System (ADS)

    Abbasi Pour, Sajjad; Shaterian, Hamid Reza; Afradi, Mojgan; Yazdani-Elah-Abadi, Afshin

    2017-09-01

    We synthesized Co0.25Cu0.25Mn0.5Fe2O4@CMC (CCMFe2O4@CMC) nanorods as a new dual-modal simultaneous for magnetic resonance imaging contrast agent and nanocarrier for drug delivery system. Impact of CCMFe2O4@CMC nanorods were investigated on the longitudinal (T1), transverse (T2) and transverse (T2∗) relaxation times for in vitro MRI contrast agent in water and also for drug delivery system, L-dopa was coated on CCMFe2O4@CMC nanorods and then in vitro drug release test was carried out at three PHs values and different temperatures. In vitro MR imaging demonstrated that r2 value of CCMFe2O4@CMC nanorods is 138.33 mM-1 s-1, CCMFe2O4@CMC is useful as T2 contrast agent relative to other T2 contrast agants. In vitro drug release test shows the amount of released L-dopa from CCMFe2O4@CMC nanorods at medium with pH = 1.2 is more than pH = 5.3 and 7.4.

  13. Contrast agent-free sonoporation: The use of an ultrasonic standing wave microfluidic system for the delivery of pharmaceutical agents

    PubMed Central

    Carugo, Dario; Ankrett, Dyan N.; Glynne-Jones, Peter; Capretto, Lorenzo; Boltryk, Rosemary J.; Zhang, Xunli; Townsend, Paul A.; Hill, Martyn

    2011-01-01

    Sonoporation is a useful biophysical mechanism for facilitating the transmembrane delivery of therapeutic agents from the extracellular to the intracellular milieu. Conventionally, sonoporation is carried out in the presence of ultrasound contrast agents, which are known to greatly enhance transient poration of biological cell membranes. However, in vivo contrast agents have been observed to induce capillary rupture and haemorrhage due to endothelial cell damage and to greatly increase the potential for cell lysis in vitro. Here, we demonstrate sonoporation of cardiac myoblasts in the absence of contrast agent (CA-free sonoporation) using a low-cost ultrasound-microfluidic device. Within this device an ultrasonic standing wave was generated, allowing control over the position of the cells and the strength of the acoustic radiation forces. Real-time single-cell analysis and retrospective post-sonication analysis of insonated cardiac myoblasts showed that CA-free sonoporation induced transmembrane transfer of fluorescent probes (CMFDA and FITC-dextran) and that different mechanisms potentially contribute to membrane poration in the presence of an ultrasonic wave. Additionally, to the best of our knowledge, we have shown for the first time that sonoporation induces increased cell cytotoxicity as a consequence of CA-free ultrasound-facilitated uptake of pharmaceutical agents (doxorubicin, luteolin, and apigenin). The US-microfluidic device designed here provides an in vitro alternative to expensive and controversial in vivo models used for early stage drug discovery, and drug delivery programs and toxicity measurements. PMID:22662060

  14. A preliminary evaluation of self-made nanobubble in contrast-enhanced ultrasound imaging

    NASA Astrophysics Data System (ADS)

    Li, Chunfang; Wu, Kaizhi; Li, Jing; Liu, Haijuan; Zhou, Qibing; Ding, Mingyue

    2014-03-01

    Nanoscale bubbles (nanobubbles) have been reported to improve contrast in tumor-targeted ultrasound imaging due to the enhanced permeation and retention effects at tumor vascular leaks. In this work, a self-made nanobubble ultrasound contrast agent was preliminarily characterized and evaluated in-vitro and in-vivo. Fundamental properties such as morphology appearance, size distribution, zeta potential, bubble concentration (bubble numbers per milliliter contrast agent suspension) and the stability of nanobubbles were assessed by light microscope and particle sizing analysis. Then the concentration intensity curve and time intensity curves (TICs) were acquired by ultrasound imaging experiment in-vitro. Finally, the contrast-enhanced ultrasonography was performed on rat to investigate the procedure of liver perfusion. The results showed that the nanobubbles had good shape and uniform distribution with the average diameter of 507.9 nm, polydispersity index (PDI) of 0.527, and zeta potential of -19.17 mV. Significant contrast enhancement was observed in in-vitro ultrasound imaging, demonstrating that the self-made nanobubbles can enhance the contrast effect of ultrasound imaging efficiently in-vitro. Slightly contrast enhancement was observed in in-vivo ultrasound imaging, indicating that the nanobubbles are not stable enough in-vivo. Future work will be focused on improving the ultrasonic imaging performance, stability, and antibody binding of the nanoscale ultrasound contrast agent.

  15. Gd-functionalised Au nanoparticles as targeted contrast agents in MRI: relaxivity enhancement by polyelectrolyte coating.

    PubMed

    Warsi, Muhammad Farooq; Adams, Ralph W; Duckett, Simon B; Chechik, Victor

    2010-01-21

    Monolayer-protected, Gd(3+)-functionalised gold nanoparticles with enhanced spin-lattice relaxivity (r(1)) were prepared; adsorption of polyelectrolytes on these materials further increased r(1) and ligand exchange with a biotin-derivatised disulfide led to a prototype avidin-targeted contrast agent.

  16. Targeted Gold Nanoparticle Contrast Agent for Digital Breast Tomosynthesis and Computed Tomography

    DTIC Science & Technology

    2012-03-01

    bromopropionic acid (10 millimolar) was dissolved in acetonitrile (100 mL) , after which sodium azide (50 millimolar) was added to the solution. The mixture was...Transformation of the ionic X-ray contrast agent diatrizoate and related triiodinated benzoates by Trametes versicolor. Appl Environ Microbiol

  17. Preparation of near-infrared-labeled targeted contrast agents for clinical translation

    NASA Astrophysics Data System (ADS)

    Olive, D. Michael

    2011-03-01

    Targeted fluorophore-labeled contrast agents are moving toward translation to human surgical use. To prepare for future clinical use, we examined the performance of potential ligands targeting the epidermal growth factor receptor, α5β3 integrins, and GLUT transporters for their suitability as directed contrast agents. Each agent was labeled with IRDye 800CW, and near-infrared dye with excitation/emission wavelengths of 789/805 nm, which we determined had favorable toxicity characteristics. The probe molecules examined consisted of Affibodies, nanobodies, peptides, and the sugar 2-deoxy-D-glucose. Each probe was tested for specific and non-specific binding in cell based assays. All probe types showed good performance in mouse models for detecting either spontaneous tumors or tumor xenografts in vivo. Each of the probes tested show promise for future human clinical studies.

  18. MATline: a job-exposure matrix for carcinogenic chemicals.

    PubMed

    Gilardi, Luisella; Falcone, Umberto; Santoro, Silvano; Coffano, Elena

    2008-01-01

    MATline is a tool that can be used to predict which industrial processes can be expected to involve the use of a substance that is considered carcinogenic as documented in the literature. The database includes agents carrying risk phrases R45, R49 and R40 according to the method of classification adopted by the EU and/or agents in categories 1, 2A and 2B as classified by the International Agency for Research on Cancer (IARC). Each agent is associated with a list of industrial processes coded according to the tariff headings used by the National Institute of Insurance against Occupational Injuries and Diseases (Istituto Nazionale per l'Assicurazione contro gli Infortuni sul Lavoro, INAIL). The main sources of information are the IARC Monographs and databases available through the National Library of Medicine's TOXNET portal. The matrix currently includes 600 carcinogenic agents, 23 classes of agents and some 7000 links between agents and industrial processes. MATline can be viewed on the www.dors.it website.

  19. The impact of injector-based contrast agent administration in time-resolved MRA.

    PubMed

    Budjan, Johannes; Attenberger, Ulrike I; Schoenberg, Stefan O; Pietsch, Hubertus; Jost, Gregor

    2018-05-01

    Time-resolved contrast-enhanced MR angiography (4D-MRA), which allows the simultaneous visualization of the vasculature and blood-flow dynamics, is widely used in clinical routine. In this study, the impact of two different contrast agent injection methods on 4D-MRA was examined in a controlled, standardized setting in an animal model. Six anesthetized Goettingen minipigs underwent two identical 4D-MRA examinations at 1.5 T in a single session. The contrast agent (0.1 mmol/kg body weight gadobutrol, followed by 20 ml saline) was injected using either manual injection or an automated injection system. A quantitative comparison of vascular signal enhancement and quantitative renal perfusion analyses were performed. Analysis of signal enhancement revealed higher peak enhancements and shorter time to peak intervals for the automated injection. Significantly different bolus shapes were found: automated injection resulted in a compact first-pass bolus shape clearly separated from the recirculation while manual injection resulted in a disrupted first-pass bolus with two peaks. In the quantitative perfusion analyses, statistically significant differences in plasma flow values were found between the injection methods. The results of both qualitative and quantitative 4D-MRA depend on the contrast agent injection method, with automated injection providing more defined bolus shapes and more standardized examination protocols. • Automated and manual contrast agent injection result in different bolus shapes in 4D-MRA. • Manual injection results in an undefined and interrupted bolus with two peaks. • Automated injection provides more defined bolus shapes. • Automated injection can lead to more standardized examination protocols.

  20. Synthesis and evaluation of nanoglobular macrocyclic Mn(II) chelate conjugates as non-gadolinium(III) MRI contrast agents.

    PubMed

    Tan, Mingqian; Ye, Zhen; Jeong, Eun-Kee; Wu, Xueming; Parker, Dennis L; Lu, Zheng-Rong

    2011-05-18

    Because of the recent observation of the toxic side effects of Gd(III) based MRI contrast agents in patients with impaired renal function, there is strong interest on developing alternative contrast agents for MRI. In this study, macrocyclic Mn(II) chelates were conjugated to nanoglobular carriers, lysine dendrimers with a silsesquioxane core, to synthesize non-Gd(III) based MRI contrast agents. A generation 3 nanoglobular conjugate of Mn(II)-1,4,7-triaazacyclononane-1,4,7-triacetate-GA amide (G3-NOTA-Mn) was also synthesized and evaluated. The per ion T(1) and T(2) relaxivities of G2, G3, G4 nanoglobular Mn(II)-DOTA monoamide conjugates decreased with increasing generation of the carriers. The T(1) relaxivities of G2, G3, and G4 nanoglobular Mn(II)-DOTA conjugates were 3.3, 2.8, and 2.4 mM(-1) s(-1) per Mn(II) chelate at 3 T, respectively. The T(1) relaxivity of G3-NOTA-Mn was 3.80 mM(-1) s(-1) per Mn(II) chelate at 3 T. The nanoglobular macrocyclic Mn(II) chelate conjugates showed good in vivo stability and were readily excreted via renal filtration. The conjugates resulted in much less nonspecific liver enhancement than MnCl(2) and were effective for contrast-enhanced tumor imaging in nude mice bearing MDA-MB-231 breast tumor xenografts at a dose of 0.03 mmol Mn/kg. The nanoglobular macrocyclic Mn(II) chelate conjugates are promising nongadolinium based MRI contrast agents.

  1. SU-F-T-664: The Efficacy of Gold Nanoparticles as Contrast Agents in Mice

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yuan, Y; Zhang, Y; Sajo, E

    Purpose: Micro-Computed Tomography (micro-CT) has been widely used as a non-invasive, high-resolution imaging modality in preclinical research. However, tumors cannot be well distinguished, since their density are similar to those of surrounding tissues, and the tumors’ natural contrast is very low. The benefits of using Gold Nanoparticles (AuNPs) as a promising high atomic weight contrast agent have been published in recent years. The aim of this study is to investigate the efficacy of AuNPs as contrast agents using different energy x-rays. Methods: The left flank of an immune-compromised athymic nude mouse was implanted with subcutaneous xenograft model of human lungmore » cancer line, A549 cells (from ATCC). After 14 days, this mouse was imaged with dual energy cone-beam micro-CT. The selected energies were 45 kVp and 65 kVp. 10µg AuNPs (200 µg/ml concentration) approximately 12 nm in size were injected subcutaneously into the tumor. The mouse was imaged 0, 3 and 24 hours post-injection. During scanning, this mouse was anesthetized. All projection raw data have been optimized and then images were reconstructed with the FDK Algorithm. Results: Based on images, at 0 hour, AuNPs provided obvious contrast no matter which energy selected, 45 kVp or 65 kVp; and using 45 kVp X-ray, AuNps showed greater contrast. After 3 hours or evenand longer, AuNPs distributed throughout the whole body of mouse, and they were not shown clearly shown in the images. Conclusion: In this study, we investigated the efficacy of AuNPs as image contrast agents at different energies with dual-energy micro-CT, using 200µg/mL of AuNPs. Sufficiently high concentrations of AuNPs are needed to be able to track intratumoral distribution. Images showed good contrast immediately following the administration of the agent but results were poor after 3 hours.« less

  2. Critical Questions Regarding Gadolinium Deposition in the Brain and Body After Injections of the Gadolinium-Based Contrast Agents, Safety, and Clinical Recommendations in Consideration of the EMA's Pharmacovigilance and Risk Assessment Committee Recommendation for Suspension of the Marketing Authorizations for 4 Linear Agents.

    PubMed

    Runge, Val M

    2017-06-01

    For magnetic resonance, the established class of intravenous contrast media is the gadolinium-based contrast agents. In the 3 decades since initial approval, these have proven in general to be very safe for human administration. However, in 2006, a devastating late adverse reaction to administration of the less stable gadolinium-based contrast agents was identified, nephrogenic systemic fibrosis. The result of actions taken by the European Medicines Agency and the US Food and Drug Administration, stratifying the agents by risk and contraindicating specific agents in severe renal dysfunction, has led to no new cases being identified in North America or Europe. Subsequently, in 2014, long-term deposition in the brain of gadolinium was first shown, after administration of 2 nonionic linear chelates, gadodiamide, and gadopentetate dimeglumine. This has led to an intense focus on the question of in vivo distribution, possible dechelation, and subsequent deposition of gadolinium, together with substantial clarification of the phenomenon as well as stratification of the agents on this basis. This review focuses on 8 critical questions regarding gadolinium deposition in the brain and body, with the answers and discussion therein important for future regulatory decisions and clinical practice. It is now clear that dechelation of gadolinium occurs in vivo with the linear agents and is responsible for this phenomenon, with key experts in the field recommending, except where there is no suitable alternative, a shift in clinical practice from the linear to macrocyclic agents. In addition, on March 10, 2017, the Pharmacovigilance and Risk Assessment Committee of the European Medicines Agency recommended suspension of the marketing authorization for 4 linear gadolinium contrast agents-specifically Omniscan, Optimark, Magnevist, and MultiHance (gadodiamide, gadoversetamide, gadopentetate dimeglumine, and gadobenate dimeglumine)-for intravenous injection. Cited in the report was convincing evidence of gadolinium deposition in the brain months after injection of these linear agents. Primovist/Eovist (gadoxetic acid disodium) will remain available, being used at a lower dose for liver imaging, because it meets an important diagnostic need. In addition, a formulation of Magnevist for intra-articular injection will remain available because of its very low gadolinium concentration.

  3. Risk for Overall Infection with Anti-TNF and Anti-integrin Agents Used in IBD: A Systematic Review and Meta-analysis.

    PubMed

    Shah, Eric D; Farida, Jeremy P; Siegel, Corey A; Chong, Kelly; Melmed, Gil Y

    2017-04-01

    The overall risk for infection with contemporary biological agents in treating Crohn's disease (CD) and ulcerative colitis (UC) has not been systematically assessed. We performed a PubMed and Cochrane database literature search to evaluate randomized, placebo-controlled trials of biologics in treating UC and CD. Meta-analysis was performed using a DerSimonian and Laird random effects model. We determined relative risk (RR) of harm against placebo; number needed to harm (NNH) was reported when appropriate. Heterogeneity and publication bias were assessed. Fourteen trials (6 UC and 8 CD) evaluating 5107 patients were included. For anti-tumor necrosis factor agents used in the treatment of UC, golimumab {NNH of 9.3, RR = 1.4 (95% confidence interval [CI], 1.04-1.8)} and pooled studies of infliximab and adalimumab (NNH = 17.2, RR = 1.2 [95% CI, 1.0-1.3]) had a statistically significant higher risk for any infection versus placebo. Risk was not significantly increased in anti-tumor necrosis factor trials in CD (RR = 1.1 [95% CI, 0.8-1.5]). By contrast, anti-integrin agents in UC (RR = 1.0 [95% CI, 0.9-1.2]) or CD (RR = 1.1 [95% CI, 0.97-1.3]) did not confer a statistically significant excess risk of infection versus placebo. Anti-tumor necrosis factor therapy but not anti-integrin therapy is associated with a greater infection risk than placebo in treating UC. Neither class of therapy is associated with increased infection risk over placebo in treating CD. Our findings can help guide patient-centered discussions regarding the risk for infection with biological agents.

  4. MRI and CT contrast media extravasation: A systematic review.

    PubMed

    Heshmatzadeh Behzadi, Ashkan; Farooq, Zerwa; Newhouse, Jeffery H; Prince, Martin R

    2018-03-01

    This systematic review combines data from multiple papers on contrast media extravasation to identify factors contributing to increased extravasation risk. Data were extracted from 17 papers reporting 2191 extravasations in 1,104,872 patients (0.2%) undergoing computed tomography (CT) or magnetic resonance imaging (MRI). Extravasation rates were 0.045% for gadolinium-based contrast agents (GBCA) and nearly 6-fold higher, 0.26% for iodinated contrast agents. Factors associated with increased contrast media extravasations included: older age, female gender, using an existing intravenous (IV) instead of placing a new IV in radiology, in-patient status, use of automated power injection, high injection rates, catheter location, and failing to warm up the more viscous contrast media to body temperature. Contrast media extravasation is infrequent but nearly 6 times less frequent with GBCA for MRI compared with iodinated contrast used in CT.

  5. Nanoengineered multimodal contrast agent for medical image guidance

    NASA Astrophysics Data System (ADS)

    Perkins, Gregory J.; Zheng, Jinzi; Brock, Kristy; Allen, Christine; Jaffray, David A.

    2005-04-01

    Multimodality imaging has gained momentum in radiation therapy planning and image-guided treatment delivery. Specifically, computed tomography (CT) and magnetic resonance (MR) imaging are two complementary imaging modalities often utilized in radiation therapy for visualization of anatomical structures for tumour delineation and accurate registration of image data sets for volumetric dose calculation. The development of a multimodal contrast agent for CT and MR with prolonged in vivo residence time would provide long-lasting spatial and temporal correspondence of the anatomical features of interest, and therefore facilitate multimodal image registration, treatment planning and delivery. The multimodal contrast agent investigated consists of nano-sized stealth liposomes encapsulating conventional iodine and gadolinium-based contrast agents. The average loading achieved was 33.5 +/- 7.1 mg/mL of iodine for iohexol and 9.8 +/- 2.0 mg/mL of gadolinium for gadoteridol. The average liposome diameter was 46.2 +/- 13.5 nm. The system was found to be stable in physiological buffer over a 15-day period, releasing 11.9 +/- 1.1% and 11.2 +/- 0.9% of the total amounts of iohexol and gadoteridol loaded, respectively. 200 minutes following in vivo administration, the contrast agent maintained a relative contrast enhancement of 81.4 +/- 13.05 differential Hounsfield units (ΔHU) in CT (40% decrease from the peak signal value achieved 3 minutes post-injection) and 731.9 +/- 144.2 differential signal intensity (ΔSI) in MR (46% decrease from the peak signal value achieved 3 minutes post-injection) in the blood (aorta), a relative contrast enhancement of 38.0 +/- 5.1 ΔHU (42% decrease from the peak signal value achieved 3 minutes post-injection) and 178.6 +/- 41.4 ΔSI (62% decrease from the peak signal value achieved 3 minutes post-injection) in the liver (parenchyma), a relative contrast enhancement of 9.1 +/- 1.7 ΔHU (94% decrease from the peak signal value achieved 3 minutes post-injection) and 461.7 +/- 78.1 ΔSI (60% decrease from the peak signal value achieved 5 minutes post-injection) in the kidney (cortex) of a New Zealand white rabbit. This multimodal contrast agent, with prolonged in vivo residence time and imaging efficacy, has the potential to bring about improvements in the fields of medical imaging and radiation therapy, particularly for image registration and guidance.

  6. The occurrence of hormetic dose responses in the toxicological literature, the hormesis database: an overview

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Calabrese, Edward J.; Blain, Robyn

    A relational retrieval database has been developed compiling toxicological studies assessing the occurrence of hormetic dose responses and their quantitative characteristics. This database permits an evaluation of these studies over numerous parameters, including study design and dose-response features and physical/chemical properties of the agents. The database contains approximately 5600 dose-response relationships satisfying evaluative criteria for hormesis across over approximately 900 agents from a broadly diversified spectrum of chemical classes and physical agents. The assessment reveals that hormetic dose-response relationships occur in males and females of numerous animal models in all principal age groups as well as across species displaying amore » broad range of differential susceptibilities to toxic agents. The biological models are extensive, including plants, viruses, bacteria, fungi, insects, fish, birds, rodents, and primates, including humans. The spectrum of endpoints displaying hormetic dose responses is also broad being inclusive of growth, longevity, numerous metabolic parameters, disease incidences (including cancer), various performance endpoints such as cognitive functions, immune responses among others. Quantitative features of the hormetic dose response reveal that the vast majority of cases display a maximum stimulatory response less than two-fold greater than the control while the width of the stimulatory response is typically less than 100-fold in dose range immediately contiguous with the toxicological NO(A)EL. The database also contains a quantitative evaluation component that differentiates among the various dose responses concerning the strength of the evidence supporting a hormetic conclusion based on study design features, magnitude of the stimulatory response, statistical significance, and reproducibility of findings.« less

  7. The occurrence of hormetic dose responses in the toxicological literature, the hormesis database: an overview.

    PubMed

    Calabrese, Edward J; Blain, Robyn

    2005-02-01

    A relational retrieval database has been developed compiling toxicological studies assessing the occurrence of hormetic dose responses and their quantitative characteristics. This database permits an evaluation of these studies over numerous parameters, including study design and dose-response features and physical/chemical properties of the agents. The database contains approximately 5600 dose-response relationships satisfying evaluative criteria for hormesis across over approximately 900 agents from a broadly diversified spectrum of chemical classes and physical agents. The assessment reveals that hormetic dose-response relationships occur in males and females of numerous animal models in all principal age groups as well as across species displaying a broad range of differential susceptibilities to toxic agents. The biological models are extensive, including plants, viruses, bacteria, fungi, insects, fish, birds, rodents, and primates, including humans. The spectrum of endpoints displaying hormetic dose responses is also broad being inclusive of growth, longevity, numerous metabolic parameters, disease incidences (including cancer), various performance endpoints such as cognitive functions, immune responses among others. Quantitative features of the hormetic dose response reveal that the vast majority of cases display a maximum stimulatory response less than two-fold greater than the control while the width of the stimulatory response is typically less than 100-fold in dose range immediately contiguous with the toxicological NO(A)EL. The database also contains a quantitative evaluation component that differentiates among the various dose responses concerning the strength of the evidence supporting a hormetic conclusion based on study design features, magnitude of the stimulatory response, statistical significance, and reproducibility of findings.

  8. Prostate-specific membrane antigen targeted protein contrast agents for molecular imaging of prostate cancer by MRI

    NASA Astrophysics Data System (ADS)

    Pu, Fan; Salarian, Mani; Xue, Shenghui; Qiao, Jingjuan; Feng, Jie; Tan, Shanshan; Patel, Anvi; Li, Xin; Mamouni, Kenza; Hekmatyar, Khan; Zou, Juan; Wu, Daqing; Yang, Jenny J.

    2016-06-01

    Prostate-specific membrane antigen (PSMA) is one of the most specific cell surface markers for prostate cancer diagnosis and targeted treatment. However, achieving molecular imaging using non-invasive MRI with high resolution has yet to be achieved due to the lack of contrast agents with significantly improved relaxivity for sensitivity, targeting capabilities and metal selectivity. We have previously reported our creation of a novel class of protein Gd3+ contrast agents, ProCA32, which displayed significantly improved relaxivity while exhibiting strong Gd3+ binding selectivity over physiological metal ions. In this study, we report our effort in further developing biomarker-targeted protein MRI contrast agents for molecular imaging of PSMA. Among three PSMA targeted contrast agents engineered with addition of different molecular recognition sequences, ProCA32.PSMA exhibits a binding affinity of 1.1 +/- 0.1 μM for PSMA while the metal binding affinity is maintained at 0.9 +/- 0.1 × 10-22 M. In addition, ProCA32.PSMA exhibits r1 of 27.6 mM-1 s-1 and r2 of 37.9 mM-1 s-1 per Gd (55.2 and 75.8 mM-1 s-1 per molecule r1 and r2, respectively) at 1.4 T. At 7 T, ProCA32.PSMA also has r2 of 94.0 mM-1 s-1 per Gd (188.0 mM-1 s-1 per molecule) and r1 of 18.6 mM-1 s-1 per Gd (37.2 mM-1 s-1 per molecule). This contrast capability enables the first MRI enhancement dependent on PSMA expression levels in tumor bearing mice using both T1 and T2-weighted MRI at 7 T. Further development of these PSMA-targeted contrast agents are expected to be used for the precision imaging of prostate cancer at an early stage and to monitor disease progression and staging, as well as determine the effect of therapeutic treatment by non-invasive evaluation of the PSMA level using MRI.Prostate-specific membrane antigen (PSMA) is one of the most specific cell surface markers for prostate cancer diagnosis and targeted treatment. However, achieving molecular imaging using non-invasive MRI with high resolution has yet to be achieved due to the lack of contrast agents with significantly improved relaxivity for sensitivity, targeting capabilities and metal selectivity. We have previously reported our creation of a novel class of protein Gd3+ contrast agents, ProCA32, which displayed significantly improved relaxivity while exhibiting strong Gd3+ binding selectivity over physiological metal ions. In this study, we report our effort in further developing biomarker-targeted protein MRI contrast agents for molecular imaging of PSMA. Among three PSMA targeted contrast agents engineered with addition of different molecular recognition sequences, ProCA32.PSMA exhibits a binding affinity of 1.1 +/- 0.1 μM for PSMA while the metal binding affinity is maintained at 0.9 +/- 0.1 × 10-22 M. In addition, ProCA32.PSMA exhibits r1 of 27.6 mM-1 s-1 and r2 of 37.9 mM-1 s-1 per Gd (55.2 and 75.8 mM-1 s-1 per molecule r1 and r2, respectively) at 1.4 T. At 7 T, ProCA32.PSMA also has r2 of 94.0 mM-1 s-1 per Gd (188.0 mM-1 s-1 per molecule) and r1 of 18.6 mM-1 s-1 per Gd (37.2 mM-1 s-1 per molecule). This contrast capability enables the first MRI enhancement dependent on PSMA expression levels in tumor bearing mice using both T1 and T2-weighted MRI at 7 T. Further development of these PSMA-targeted contrast agents are expected to be used for the precision imaging of prostate cancer at an early stage and to monitor disease progression and staging, as well as determine the effect of therapeutic treatment by non-invasive evaluation of the PSMA level using MRI. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr09071g

  9. Synthesis of DTPA analogues derived from piperidine and azepane: potential contrast enhancement agents for magnetic resonance imaging.

    PubMed

    Chong, H S; Garmestani, K; Bryant, L H; Brechbiel, M W

    2001-11-16

    Two DTPA derivatives (PIP-DTPA and AZEP-DTPA) as potential contrast enhancement agents in MRI are synthesized. The T1 and T2 relaxivities of their corresponding Gd(III) complexes are reported. At clinically relevant field strengths, the relaxivities of the complexes are comparable to that of the contrast agent, Gd(DTPA) which is in clinical use. The serum stability of the (153)Gd-labeled complexes is assessed by measuring the release of (153)Gd from the ligands. The radiolabeled Gd chelates are found to be kinetically stable in human serum for up to at least 14 days without any measurable loss of radioactivity.

  10. A smart T(1)-weighted MRI contrast agent for uranyl cations based on a DNAzyme-gadolinium conjugate.

    PubMed

    Xu, Weichen; Xing, Hang; Lu, Yi

    2013-11-07

    Rational design of smart MRI contrast agents with high specificity for metal ions remains a challenge. Here, we report a general strategy for the design of smart MRI contrast agents for detecting metal ions based on conjugation of a DNAzyme with a gadolinium complex. The 39E DNAzyme, which has high selectivity for UO2(2+), was conjugated to Gd(III)-DOTA and streptavidin. The binding of UO2(2+) to its 39E DNAzyme resulted in the dissociation of Gd(III)-DOTA from the large streptavidin, leading to a decrease of the T1 correlation time, and a change in the MRI signal.

  11. Contrast-enhanced photoacoustic tomography of human joints

    NASA Astrophysics Data System (ADS)

    Tian, Chao; Keswani, Rahul K.; Gandikota, Girish; Rosania, Gus R.; Wang, Xueding

    2016-03-01

    Photoacoustic tomography (PAT) provides a unique tool to diagnose inflammatory arthritis. However, the specificity and sensitivity of PAT based on endogenous contrasts is limited. The development of contrast enhanced PAT imaging modalities in combination with small molecule contrast agents could lead to improvements in diagnosis and treatment of joint disease. Accordingly, we adapted and tested a PAT clinical imaging system for imaging the human joints, in combination with a novel PAT contrast agent derived from an FDA-approved small molecule drug. Imaging results based on a photoacoustic and ultrasound (PA/US) dual-modality system revealed that this contrast-enhanced PAT imaging system may offer additional information beyond single-modality PA or US imaging system, for the imaging, diagnosis and assessment of inflammatory arthritis.

  12. Interoperability, Data Control and Battlespace Visualization using XML, XSLT and X3D

    DTIC Science & Technology

    2003-09-01

    26 Rosenthal, Arnon, Seligman , Len and Costello, Roger, XML, Databases, and Interoperability, Federal Database Colloquium, AFCEA, San Diego...79 Rosenthal, Arnon, Seligman , Len and Costello, Roger, “XML, Databases, and Interoperability”, Federal Database Colloquium, AFCEA, San Diego, 1999... Linda , Mastering XML, Premium Edition, SYBEX, 2001 Wooldridge, Michael , An Introduction to MultiAgent Systems, Wiley, 2002 PAPERS Abernathy, M

  13. Surface and interfacial engineering of iron oxide nanoplates for highly efficient magnetic resonance angiography.

    PubMed

    Zhou, Zijian; Wu, Changqiang; Liu, Hanyu; Zhu, Xianglong; Zhao, Zhenghuan; Wang, Lirong; Xu, Ye; Ai, Hua; Gao, Jinhao

    2015-03-24

    Magnetic resonance angiography using gadolinium-based molecular contrast agents suffers from short diagnostic window, relatively low resolution and risk of toxicity. Taking into account the chemical exchange between metal centers and surrounding protons, magnetic nanoparticles with suitable surface and interfacial features may serve as alternative T1 contrast agents. Herein, we report the engineering on surface structure of iron oxide nanoplates to boost T1 contrast ability through synergistic effects between exposed metal-rich Fe3O4(100) facets and embedded Gd2O3 clusters. The nanoplates show prominent T1 contrast in a wide range of magnetic fields with an ultrahigh r1 value up to 61.5 mM(-1) s(-1). Moreover, engineering on nanobio interface through zwitterionic molecules adjusts the in vivo behaviors of nanoplates for highly efficient magnetic resonance angiography with steady-state acquisition window, superhigh resolution in vascular details, and low toxicity. This study provides a powerful tool for sophisticated design of MRI contrast agents for diverse use in bioimaging applications.

  14. Excess of Radiation Burden for Young Testicular Cancer Patients using Automatic Exposure Control and Contrast Agent on Whole-body Computed Tomography Imaging.

    PubMed

    Niiniviita, Hannele; Kulmala, Jarmo; Pölönen, Tuukka; Määttänen, Heli; Järvinen, Hannu; Salminen, Eeva

    2017-06-01

    The aim of the study was to assess patient dose from whole-body computed tomography (CT) in association with patient size, automatic exposure control (AEC) and intravenous (IV) contrast agent. Sixty-five testicular cancer patients (mean age 28 years) underwent altogether 279 whole-body CT scans from April 2000 to April 2011. The mean number of repeated examinations was 4.3. The GE LightSpeed 16 equipped with AEC and the Siemens Plus 4 CT scanners were used for imaging. Whole-body scans were performed with (216) and without (63) IV contrast. The ImPACT software was used to determine the effective and organ doses. Patient doses were independent (p < 0.41) of patient size when the Plus 4 device (mean 7.4 mSv, SD 1.7 mSv) was used, but with the LightSpeed 16 AEC device, the dose (mean 14 mSv, SD 4.6 mSv) increased significantly (p < 0.001) with waist cirfumference. Imaging with the IV contrast agent caused significantly higher (13% Plus 4, 35% LightSpeed 16) exposure than non-contrast imaging (p < 0.001). Great caution on the use of IV contrast agent and careful set-up of the AEC modulation parameters is recommended to avoid excessive radiation exposure on the whole-body CT imaging of young patients.

  15. Manganese ferrite nanoparticle micellar nanocomposites as MRI contrast agent for liver imaging.

    PubMed

    Lu, Jian; Ma, Shuli; Sun, Jiayu; Xia, Chunchao; Liu, Chen; Wang, Zhiyong; Zhao, Xuna; Gao, Fabao; Gong, Qiyong; Song, Bin; Shuai, Xintao; Ai, Hua; Gu, Zhongwei

    2009-05-01

    Iron oxide nanoparticles are effective contrast agents for enhancement of magnetic resonance imaging at tissue, cellular or even molecular levels. In this study, manganese doped superparamagnetic iron oxide (Mn-SPIO) nanoparticles were used to form ultrasensitive MRI contrast agents for liver imaging. Hydrophobic Mn-SPIO nanoparticles are synthesized in organic phase and then transferred into water with the help of block copolymer mPEG-b-PCL. These Mn-SPIO nanoparticles are self-assembled into small clusters (mean diameter approximately 80nm) inside micelles as revealed by transmission electron microscopy. Mn-SPIO nanoparticles inside micelles decrease PCL crystallization temperatures, as verified from differential scanning calorimetry and Fourier transform infrared spectroscopy. The Mn-SPIO based nanocomposites are superparamagnetic at room temperature. At the magnetic field of 1.5T, Mn-SPIO nanoparticle clustering micelles have a T(2) relaxivity of 270 (Mn+Fe)mM(-1)s(-1), which is much higher than single Mn-SPIO nanoparticle containing lipid-PEG micelles. This clustered nanocomposite has brought significant liver contrast with signal intensity changes of -80% at 5min after intravenous administration. The time window for enhanced-MRI can last about 36h with obvious contrast on liver images. This sensitive MRI contrast agent may find applications in identification of small liver lesions, evaluation of the degree of liver cirrhosis, and differential diagnosis of other liver diseases.

  16. Evaluating the potential of chelation therapy to prevent and treat gadolinium deposition from MRI contrast agents

    DOE PAGES

    Rees, Julian A.; Deblonde, Gauthier J. -P.; An, Dahlia D.; ...

    2018-03-13

    Several MRI contrast agent clinical formulations are now known to leave deposits of the heavy metal gadolinium in the brain, bones, and other organs of patients. This persistent biological accumulation of gadolinium has been recently recognized as a deleterious outcome in patients administered Gd-based contrast agents (GBCAs) for MRI, prompting the European Medicines Agency to recommend discontinuing the use of over half of the GBCAs currently approved for clinical applications. Here, to address this problem, we find that the orally-available metal decorporation agent 3,4,3-LI(1,2-HOPO) demonstrates superior efficacy at chelating and removing Gd from the body compared to diethylenetriaminepentaacetic acid, amore » ligand commonly used in the United States in the GBCA Gadopentetate (Magnevist). Using the radiotracer 153Gd to obtain precise biodistribution data, the results herein, supported by speciation simulations, suggest that the prophylactic or post-hoc therapeutic use of 3,4,3-LI(1,2-HOPO) may provide a means to mitigate Gd retention in patients requiring contrast-enhanced MRI.« less

  17. Evaluating the potential of chelation therapy to prevent and treat gadolinium deposition from MRI contrast agents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rees, Julian A.; Deblonde, Gauthier J. -P.; An, Dahlia D.

    Several MRI contrast agent clinical formulations are now known to leave deposits of the heavy metal gadolinium in the brain, bones, and other organs of patients. This persistent biological accumulation of gadolinium has been recently recognized as a deleterious outcome in patients administered Gd-based contrast agents (GBCAs) for MRI, prompting the European Medicines Agency to recommend discontinuing the use of over half of the GBCAs currently approved for clinical applications. Here, to address this problem, we find that the orally-available metal decorporation agent 3,4,3-LI(1,2-HOPO) demonstrates superior efficacy at chelating and removing Gd from the body compared to diethylenetriaminepentaacetic acid, amore » ligand commonly used in the United States in the GBCA Gadopentetate (Magnevist). Using the radiotracer 153Gd to obtain precise biodistribution data, the results herein, supported by speciation simulations, suggest that the prophylactic or post-hoc therapeutic use of 3,4,3-LI(1,2-HOPO) may provide a means to mitigate Gd retention in patients requiring contrast-enhanced MRI.« less

  18. Synthesis and characterization of superparamagnetic iron oxide nanoparticles as calcium-responsive MRI contrast agents

    NASA Astrophysics Data System (ADS)

    Xu, Pengfei; Shen, Zhiwei; Zhang, Baolin; Wang, Jun; Wu, Renhua

    2016-12-01

    Superparamagnetic iron oxide nanoparticles (SPIONs) as T2 contrast agents have great potential to sense calcium ion (Ca2+) using magnetic resonance imaging (MRI). Here we prepared calcium-responsive SPIONs for MRI, formed by combining poly(ethylene glycol) (PEG) and polyethylenimine (PEI) coated iron oxide nanoparticle (PEI/PEG-SPIONs) contrast agents with the straightforward calcium-sensing compound EGTA (ethylene glycol tetraacetic acid). EGTA was conjugated onto PEI/PEG-SPIONs using EDC/sulfo-NHS method. EGTA-SPIONs were characterized using TEM, XPS, DSL, TGA and SQUIID. DSL results show that the SPIONs aggregate in the presence of Ca2+. MRI analyses indicate that the water proton T2 relaxation rates in HEPES suspensions of the EGTA-SPIONs significantly increase with the calcium concentration because the SPIONs aggregate in the presence of Ca2+. The T2 values decreased 25% when Ca2+ concentration decreased from 1.2 to 0.8 mM. The aggregation of EGTA-SPIONs could be reversed by EDTA. EGTA-SPIONs have potential as smart contrast agents for Ca2+-sensitive MRI.

  19. Cavitation thresholds of contrast agents in an in vitro human clot model exposed to 120-kHz ultrasound.

    PubMed

    Gruber, Matthew J; Bader, Kenneth B; Holland, Christy K

    2014-02-01

    Ultrasound contrast agents (UCAs) can be employed to nucleate cavitation to achieve desired bioeffects, such as thrombolysis, in therapeutic ultrasound applications. Effective methods of enhancing thrombolysis with ultrasound have been examined at low frequencies (<1 MHz) and low amplitudes (<0.5 MPa). The objective of this study was to determine cavitation thresholds for two UCAs exposed to 120-kHz ultrasound. A commercial ultrasound contrast agent (Definity(®)) and echogenic liposomes were investigated to determine the acoustic pressure threshold for ultraharmonic (UH) and broadband (BB) generation using an in vitro flow model perfused with human plasma. Cavitation emissions were detected using two passive receivers over a narrow frequency bandwidth (540-900 kHz) and a broad frequency bandwidth (0.54-1.74 MHz). UH and BB cavitation thresholds occurred at the same acoustic pressure (0.3 ± 0.1 MPa, peak to peak) and were found to depend on the sensitivity of the cavitation detector but not on the nucleating contrast agent or ultrasound duty cycle.

  20. Highly stable silica-coated manganese ferrite nanoparticles as high-efficacy T2 contrast agents for magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Ahmad, Ashfaq; Bae, Hongsub; Rhee, Ilsu

    2018-05-01

    Highly stable silica-coated manganese ferrite nanoparticles were fabricated for application as magnetic resonance imagining (MRI) contrast agents. The manganese ferrite nanoparticles were synthesized using a hydrothermal technique and coated with silica. The particle size was investigated using transmission electron microscopy and was found to be 40-60 nm. The presence of the silica coating on the particle surface was confirmed by Fourier transform infrared spectroscopy. The crystalline structure was investigated by X-ray diffraction, and the particles were revealed to have an inverse spinel structure. Superparamagnetism was confirmed by the magnetic hysteresis curves obtained using a vibrating sample magnetometer. The efficiency of the MRI contrast agents was investigated by using aqueous solutions of the particles in a 4.7 T MRI scanner. The T1 and T2 relaxivities of the particles were 1.42 and 60.65 s-1 mM-1, respectively, in water. The ratio r2/r1 was 48.91, confirming that the silica-coated manganese ferrite nanoparticles were suitable high-efficacy T2 contrast agents.

  1. Towards a nanoscale mammographic contrast agent: development of a modular pre-clinical dual optical/x-ray agent

    NASA Astrophysics Data System (ADS)

    Hill, Melissa L.; Gorelikov, Ivan; Niroui, Farnaz; Levitin, Ronald B.; Mainprize, James G.; Yaffe, Martin J.; Rowlands, J. A.; Matsuura, Naomi

    2013-08-01

    Contrast-enhanced digital mammography (CEDM) can provide improved breast cancer detection and characterization compared to conventional mammography by imaging the effects of tumour angiogenesis. Current small-molecule contrast agents used for CEDM are limited by a short plasma half-life and rapid extravasation into tissue interstitial space. To address these limitations, nanoscale agents that can remain intravascular except at sites of tumour angiogenesis can be used. For CEDM, this agent must be both biocompatible and strongly attenuate mammographic energy x-rays. Nanoscale perfluorooctylbromide (PFOB) droplets have good x-ray attenuation and have been used in patients for other applications. However, the macroscopic scale of x-ray imaging (50-100 µm) is inadequate for direct verification that PFOB droplets localize at sites of breast tumour angiogenesis. For efficient pre-clinical optimization for CEDM, we integrated an optical marker into PFOB droplets for microscopic assessment (≪50 µm). To develop PFOB droplets as a new nanoscale mammographic contrast agent, PFOB droplets were labelled with fluorescent quantum dots (QDs). The droplets had mean diameters of 160 nm, fluoresced at 635 nm and attenuated x-ray spectra at 30.5 keV mean energy with a relative attenuation of 5.6 ± 0.3 Hounsfield units (HU) mg-1 mL-1 QD-PFOB. With the agent loaded into tissue phantoms, good correlation between x-ray attenuation and optical fluorescence was found (R2 = 0.96), confirming co-localization of the QDs with PFOB for quantitative assessment using x-ray or optical methods. Furthermore, the QDs can be removed from the PFOB agent without affecting its x-ray attenuation or structural properties for expedited translation of optimized PFOB droplet formulations into patients.

  2. Acoustic fingerprints of photoacoustic contrast agents for molecular imaging

    NASA Astrophysics Data System (ADS)

    McDonald, Michael A.; Jankovic, Ladislav; Shahzad, Khalid; Burcher, Michael; Li, King C. P.

    2007-02-01

    Protein nanospheres capable of frequency controlled oscillation in response to laser stimulation are presented as contrast agents for photoacoustic imaging. Incident laser energy absorbed by dye-labeled protein nanospheres causes thermoelastically generated sound production. Plotted A-line graphs reveal a distinctive morphology and greater than 2 orders of magnitude increase in signal amplitude subsequent to converting labeled proteins into nanospheres. Evidence of nonlinearity and enhancement of ultrasound backscatter indicate a potential use in contrast-enhanced harmonic imaging. Photoacoustic and ultrasound imaging of protein nanospheres in phantom vessels show enhanced contrast at low concentration and clear delineation of the phantom vessel wall.

  3. Modeling contrast agent flow in cerebral aneurysms: comparison of CFD with medical imaging

    NASA Astrophysics Data System (ADS)

    Rayz, Vitaliy; Vali, Alireza; Sigovan, Monica; Lawton, Michael; Saloner, David; Boussel, Loic

    2016-11-01

    PURPOSE: The flow in cerebral aneurysms is routinely assessed with X-ray angiography, an imaging technique based on a contrast agent injection. In addition to requiring a patient's catheterization and radiation exposure, the X-ray angiography may inaccurately estimate the flow residence time, as the injection alters the native blood flow patterns. Numerical modeling of the contrast transport based on MRI imaging, provides a non-invasive alternative for the flow diagnostics. METHODS: The flow in 3 cerebral aneurysms was measured in vivo with 4D PC-MRI, which provides time-resolved, 3D velocity field. The measured velocities were used to simulate a contrast agent transport by solving the advection-diffusion equation. In addition, the flow in the same patient-specific geometries was simulated with CFD and the velocities obtained from the Navier-Stokes solution were used to model the transport of a virtual contrast. RESULTS: Contrast filling and washout patterns obtained in simulations based on MRI-measured velocities were in agreement with those obtained using the Navier-Stokes solution. Some discrepancies were observed in comparison to the X-ray angiography data, as numerical modeling of the contrast transport is based on the native blood flow unaffected by the contrast injection. NIH HL115267.

  4. Small animal imaging platform for quantitative assessment of short-wave infrared-emitting contrast agents

    NASA Astrophysics Data System (ADS)

    Hu, Philip; Mingozzi, Marco; Higgins, Laura M.; Ganapathy, Vidya; Zevon, Margot; Riman, Richard E.; Roth, Charles M.; Moghe, Prabhas V.; Pierce, Mark C.

    2015-03-01

    We report the design, calibration, and testing of a pre-clinical small animal imaging platform for use with short-wave infrared (SWIR) emitting contrast agents. Unlike materials emitting at visible or near-infrared wavelengths, SWIR-emitting agents require detection systems with sensitivity in the 1-2 μm wavelength region, beyond the range of commercially available small animal imagers. We used a collimated 980 nm laser beam to excite rare-earth-doped NaYF4:Er,Yb nanocomposites, as an example of a SWIR emitting material under development for biomedical imaging applications. This beam was raster scanned across the animal, with fluorescence in the 1550 nm wavelength region detected by an InGaAs area camera. Background adjustment and intensity non-uniformity corrections were applied in software. The final SWIR fluorescence image was overlaid onto a standard white-light image for registration of contrast agent uptake with respect to anatomical features.

  5. Self-assembled dual-modality contrast agents for non-invasive stem cell tracking via near-infrared fluorescence and magnetic resonance imaging.

    PubMed

    Liu, Hong; Tan, Yan; Xie, Lisi; Yang, Lei; Zhao, Jing; Bai, Jingxuan; Huang, Ping; Zhan, Wugen; Wan, Qian; Zou, Chao; Han, Yali; Wang, Zhiyong

    2016-09-15

    Stem cells hold great promise for treating various diseases. However, one of the main drawbacks of stem cell therapy is the lack of non-invasive image-tracking technologies. Although magnetic resonance imaging (MRI) and near-infrared fluorescence (NIRF) imaging have been employed to analyse cellular and subcellular events via the assistance of contrast agents, the sensitivity and temporal resolution of MRI and the spatial resolution of NIRF are still shortcomings. In this study, superparamagnetic iron oxide nanocrystals and IR-780 dyes were co-encapsulated in stearic acid-modified polyethylenimine to form a dual-modality contrast agent with nano-size and positive charge. These resulting agents efficiently labelled stem cells and did not influence the cellular viability and differentiation. Moreover, the labelled cells showed the advantages of dual-modality imaging in vivo. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Rapid Catalyst Capture Enables Metal-Free para-Hydrogen-Based Hyperpolarized Contrast Agents.

    PubMed

    Barskiy, Danila A; Ke, Lucia A; Li, Xingyang; Stevenson, Vincent; Widarman, Nevin; Zhang, Hao; Truxal, Ashley; Pines, Alexander

    2018-05-10

    Hyperpolarization techniques based on the use of para-hydrogen provide orders of magnitude signal enhancement for magnetic resonance spectroscopy and imaging. The main drawback limiting widespread applicability of para-hydrogen-based techniques in biomedicine is the presence of organometallic compounds (the polarization transfer catalysts) in solution with hyperpolarized contrast agents. These catalysts are typically complexes of platinum-group metals, and their administration in vivo should be avoided. Herein, we show how extraction of a hyperpolarized compound from an organic phase to an aqueous phase combined with a rapid (less than 10 s) Ir-based catalyst capture by metal scavenging agents can produce pure para-hydrogen-based hyperpolarized contrast agents, as demonstrated by high-resolution nuclear magnetic resonance (NMR) spectroscopy and inductively coupled plasma atomic emission spectroscopy (ICP-AES). The presented methodology enables fast and efficient means of producing pure hyperpolarized aqueous solutions for biomedical and other uses.

  7. Automated Agent Ontology Creation for Distributed Databases

    DTIC Science & Technology

    2004-03-01

    relationships between themselves if one exists. For example, if one agent’s ontology was ‘ NBA ’ and the second agent’s ontology was ‘College Hoops...the two agents should discover their relationship ‘ basketball ’ [28]. The authors’ agents use supervised inductive learning to learn their individual

  8. A neutral polydisulfide containing Gd(III) DOTA monoamide as a redox-sensitive biodegradable macromolecular MRI contrast agent.

    PubMed

    Ye, Zhen; Zhou, Zhuxian; Ayat, Nadia; Wu, Xueming; Jin, Erlei; Shi, Xiaoyue; Lu, Zheng-Rong

    2016-01-01

    This work aims to develop safe and effective gadolinium (III)-based biodegradable macromolecular MRI contrast agents for blood pool and cancer imaging. A neutral polydisulfide containing macrocyclic Gd-DOTA monoamide (GOLS) was synthesized and characterized. In addition to studying the in vitro degradation of GOLS, its kinetic stability was also investigated in an in vivo model. The efficacy of GOLS for contrast-enhanced MRI was examined with female BALB/c mice bearing 4T1 breast cancer xenografts. The pharmacokinetics, biodistribution, and metabolism of GOLS were also determined in mice. GOLS has an apparent molecular weight of 23.0 kDa with T1 relaxivities of 7.20 mM(-1) s(-1) per Gd at 1.5 T, and 6.62 mM(-1) s(-1) at 7.0 T. GOLS had high kinetic inertness against transmetallation with Zn(2+) ions, and its polymer backbone was readily cleaved by L-cysteine. The agent showed improved efficacy for blood pool and tumor MR imaging. The structural effect on biodistribution and in vivo chelation stability was assessed by comparing GOLS with Gd(HP-DO3A), a negatively charged polydisulfide containing Gd-DOTA monoamide GODC, and a polydisulfide containing Gd-DTPA-bisamide (GDCC). GOLS showed high in vivo chelation stability and minimal tissue deposition of gadolinium. The biodegradable macromolecular contrast agent GOLS is a promising polymeric contrast agent for clinical MR cardiovascular imaging and cancer imaging. Copyright © 2015 John Wiley & Sons, Ltd.

  9. Macrophages mediated diagnosis of rheumatoid arthritis using fibrin based magnetic nanoparticles as MRI contrast agents.

    PubMed

    Periyathambi, Prabu; Sastry, Thotapalli Parvathaleswara; Anandasadagopan, Suresh Kumar; Manickavasagam, Kanagavel

    2017-01-01

    A variety of bioimaging tools assists in the diagnosis and evaluation of rheumatoid arthritis (RA) and other osteoarthritis. However, detection of RA in the early stages by targeting its macrophages with suitable contrast agents will help in arresting the progression of the disease. In the present study, we investigated the effectiveness of using magnetic fibrin nanoparticles (MFNPs) conjugated with folic acid (FA-MFNPs) as a specific contrast agent to target the activated macrophages, which overexpress the folate receptors (FR) in the knee joints of rats with antigen-induced arthritis (AIA). FA-MFNPs were spherical with an average size of 18.3±1.6nm. In vitro studies have shown effective internalization of FA-MFNPs into the Raw264.7 macrophage cells. In vivo studies were carried out by injecting FA-MFNPs intravenously into the arthritic rats. The results showed enhanced MR imaging in the synovium of arthritic joints. Prussian blue histological staining confirmed uptake of FA-MFNPs by macrophages in the synovial tissue. The animal experiment results indicate that FA-MFNPs can be used as a specific MRI contrast agent in identifying phagocytic active macrophages in the synovial joints. Blood is the precursor source for synthesising the fibrin-based iron oxide (magnetic) nanoparticles (MFNPs) with diameters between 12 and 15nm. It has excellent superparamagnetic behaviour, biocompatibility, osteogenic potency, hemocompatibility, and biodegradable properties. MFNPs-based nanocomposites might be a promising contrast agent for bioimaging. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Whole-body multicolor spectrally resolved fluorescence imaging for development of target-specific optical contrast agents using genetically engineered probes

    NASA Astrophysics Data System (ADS)

    Kobayashi, Hisataka; Hama, Yukihiro; Koyama, Yoshinori; Barrett, Tristan; Urano, Yasuteru; Choyke, Peter L.

    2007-02-01

    Target-specific contrast agents are being developed for the molecular imaging of cancer. Optically detectable target-specific agents are promising for clinical applications because of their high sensitivity and specificity. Pre clinical testing is needed, however, to validate the actual sensitivity and specificity of these agents in animal models, and involves both conventional histology and immunohistochemistry, which requires large numbers of animals and samples with costly handling. However, a superior validation tool takes advantage of genetic engineering technology whereby cell lines are transfected with genes that induce the target cell to produce fluorescent proteins with characteristic emission spectra thus, identifying them as cancer cells. Multicolor fluorescence imaging of these genetically engineered probes can provide rapid validation of newly developed exogenous probes that fluoresce at different wavelengths. For example, the plasmid containing the gene encoding red fluorescent protein (RFP) was transfected into cell lines previously developed to either express or not-express specific cell surface receptors. Various antibody-based or receptor ligand-based optical contrast agents with either green or near infrared fluorophores were developed to concurrently target and validate cancer cells and their positive and negative controls, such as β-D-galactose receptor, HER1 and HER2 in a single animal/organ. Spectrally resolved fluorescence multicolor imaging was used to detect separate fluorescent emission spectra from the exogenous agents and RFP. Therefore, using this in vivo imaging technique, we were able to demonstrate the sensitivity and specificity of the target-specific optical contrast agents, thus reducing the number of animals needed to conduct these experiments.

  11. Contrast Media: Are There Differences in Nephrotoxicity among Contrast Media?

    PubMed Central

    2014-01-01

    Iodinated contrast agents are usually classified based upon their osmolality—high, low, and isosmolar. Iodinated contrast agents are also nephrotoxic in some but not all patients resulting in loss of glomerular filtration rate. Over the past 30 years, nephrotoxicity has been linked to osmolality although the precise mechanism underlying such a link has been elusive. Improvements in our understanding of the pathogenesis of nephrotoxicity and prospective randomized clinical trials have attempted to further explore the relationship between osmolality and nephrotoxicity. In this review, the basis for our current understanding that there are little if any differences in nephrotoxic potential between low and isosmolar contrast media will be detailed using data from clinical studies. PMID:24587997

  12. Development of Bifunctional Gadolinium-Labeled Superparamagnetic Nanoparticles (Gd-MnMEIO) for In Vivo MR Imaging of the Liver in an Animal Model.

    PubMed

    Kuo, Yu-Ting; Chen, Chiao-Yun; Liu, Gin-Chung; Wang, Yun-Ming

    2016-01-01

    Liver tumors are common and imaging methods, particularly magnetic resonance imaging (MRI), play an important role in their non-invasive diagnosis. Previous studies have shown that detection of liver tumors can be improved by injection of two different MR contrast agents. Here, we developed a new contrast agent, Gd-manganese-doped magnetism-engineered iron oxide (Gd-MnMEIO), with enhancement effects on both T1- and T2-weighted MR images of the liver. A 3.0T clinical MR scanner equipped with transmit/receiver coil for mouse was used to obtain both T1-weighted spoiled gradient-echo and T2-weighted fast spin-echo axial images of the liver before and after intravenous contrast agent injection into Balb/c mice with and without tumors. After pre-contrast scanning, six mice per group were intravenously injected with 0.1 mmol/kg Gd-MnMEIO, or the control agents, i.e., Gd-DTPA or SPIO. The scanning time points for T1-weighted images were 0.5, 5, 10, 15, 20, 25, and 30 min after contrast administration. The post-enhanced T2-weighted images were then acquired immediately after T1-weighted acquisition. We found that T1-weighted images were positively enhanced by both Gd-DTPA and Gd-MnMEIO and negatively enhanced by SPIO. The enhancement by both Gd-DTPA and Gd-MnMEIO peaked at 0.5 min and gradually declined thereafter. Gd-MnMEIO (like Gd-DTPA) enhanced T1-weighted images and (like SPIO) T2-weighted images. Marked vascular enhancement was clearly visible on dynamic T1-weighted images with Gd-MnMEIO. In addition, the T2 signal was significantly decreased at 30 min after administration of Gd-MnMEIO. Whereas the effects of Gd-MnMEIO and SPIO on T2-weighted images were similar (p = 0.5824), those of Gd-MnMEIO and Gd-DTPA differed, with Gd-MnMEIO having a significant T2 contrast effect (p = 0.0086). Our study confirms the feasibility of synthesizing an MR contrast agent with both T1 and T2 shortening effects and using such an agent in vivo. This agent enables tumor detection and characterization in single liver MRI sections.

  13. Gd-DTPA L-cystine bisamide copolymers as novel biodegradable macromolecular contrast agents for MR blood pool imaging.

    PubMed

    Kaneshiro, Todd L; Ke, Tianyi; Jeong, Eun-Kee; Parker, Dennis L; Lu, Zheng-Rong

    2006-06-01

    The purpose of this study was to synthesize biodegradable Gd-DTPA L-cystine bisamide copolymers (GCAC) as safe and effective, macromolecular contrast agents for magnetic resonance imaging (MRI) and to evaluate their biodegradability and efficacy in MR blood pool imaging in an animal model. Three new biodegradable GCAC with different substituents at the cystine bisamide [R = H (GCAC), CH2CH2CH3 (Gd-DTPA L-cystine bispropyl amide copolymers, GCPC), and CH(CH3)2 (Gd-DTPA cystine bisisopropyl copolymers, GCIC)] were prepared by the condensation copolymerization of diethylenetriamine pentaacetic acid (DTPA) dianhydride with cystine bisamide or bisalkyl amides, followed by complexation with gadolinium triacetate. The degradability of the agents was studied in vitro by incubation in 15 microM cysteine and in vivo with Sprague-Dawley rats. The kinetics of in vivo contrast enhancement was investigated in Sprague-Dawley rats on a Siemens Trio 3 T scanner. The apparent molecular weight of the polydisulfide Gd(III) chelates ranged from 22 to 25 kDa. The longitudinal (T1) relaxivities of GCAC, GCPC, and GCIC were 4.37, 5.28, and 5.56 mM(-1) s(-1) at 3 T, respectively. The polymeric ligands and polymeric Gd(III) chelates readily degraded into smaller molecules in incubation with 15 microM cysteine via disulfide-thiol exchange reactions. The in vitro degradation rates of both the polymeric ligands and macromolecular Gd(III) chelates decreased as the steric effect around the disulfide bonds increased. The agents readily degraded in vivo, and the catabolic degradation products were detected in rat urine samples collected after intravenous injection. The agents showed strong contrast enhancement in the blood pool, major organs, and tissues at a dose of 0.1 mmol Gd/kg. The difference of their in vitro degradability did not significantly alter the kinetics of in vivo contrast enhancement of the agents. These novel GCAC are promising contrast agents for cardiovascular and tumor MRI, which are later cleaved into low molecular weight Gd(III) chelates and rapidly cleared from the body.

  14. Numerical modeling of the 3D dynamics of ultrasound contrast agent microbubbles using the boundary integral method

    NASA Astrophysics Data System (ADS)

    Wang, Qianxi; Manmi, Kawa; Calvisi, Michael L.

    2015-02-01

    Ultrasound contrast agents (UCAs) are microbubbles stabilized with a shell typically of lipid, polymer, or protein and are emerging as a unique tool for noninvasive therapies ranging from gene delivery to tumor ablation. While various models have been developed to describe the spherical oscillations of contrast agents, the treatment of nonspherical behavior has received less attention. However, the nonspherical dynamics of contrast agents are thought to play an important role in therapeutic applications, for example, enhancing the uptake of therapeutic agents across cell membranes and tissue interfaces, and causing tissue ablation. In this paper, a model for nonspherical contrast agent dynamics based on the boundary integral method is described. The effects of the encapsulating shell are approximated by adapting Hoff's model for thin-shell, spherical contrast agents. A high-quality mesh of the bubble surface is maintained by implementing a hybrid approach of the Lagrangian method and elastic mesh technique. The numerical model agrees well with a modified Rayleigh-Plesset equation for encapsulated spherical bubbles. Numerical analyses of the dynamics of UCAs in an infinite liquid and near a rigid wall are performed in parameter regimes of clinical relevance. The oscillation amplitude and period decrease significantly due to the coating. A bubble jet forms when the amplitude of ultrasound is sufficiently large, as occurs for bubbles without a coating; however, the threshold amplitude required to incite jetting increases due to the coating. When a UCA is near a rigid boundary subject to acoustic forcing, the jet is directed towards the wall if the acoustic wave propagates perpendicular to the boundary. When the acoustic wave propagates parallel to the rigid boundary, the jet direction has components both along the wave direction and towards the boundary that depend mainly on the dimensionless standoff distance of the bubble from the boundary. In all cases, the jet directions for the coated and uncoated bubble are similar but the jet width and jet velocity are smaller for a coated bubble. The effects of shell thickness and shell viscosity are analyzed and determined to affect the bubble dynamics, including jet development.

  15. [Development of Biliary Contrast Agents Remote Pushing Device].

    PubMed

    Zhu, Haoyang; Dong, Dinghui; Luo, Yu; Ren, Fenggang; Zhang, Jing; Tan, Wenjun; Shi, Aihua; Hu, Liangshuo; Wu, Rongqian; Lyu, Yi

    2018-01-30

    A biliary contrast agents pushing device, including a syringe pushing system and a remote controller is introduced. The syringe pushing system comprises an injector card slot, a support platform and an injection bolus fader. A 20 mL syringe can be fitted on the syringe pushing system and kept with the ground about 30 degree. This system can perform air bubble pumping back and contrast agents bolus injection as well as speed adjustment. Remote controller is an infrared remote control which can start and stop the syringe pushing system. With this device, the remote controlled cholangiography technology can be achieved, which can not only protect doctors from X-ray radiation but also improve the traditional T-tube cholangiography and the contrast effect, reduce postoperative complications in patients as well. The application of this device will improve the current diagnosis and treatment system, the device will benefit the majority of doctors and patients.

  16. Size effect of Au/PAMAM contrast agent on CT imaging of reticuloendothelial system and tumor tissue

    NASA Astrophysics Data System (ADS)

    Wang, Wei; Li, Jian; Liu, Ransheng; Zhang, Aixu; Yuan, Zhiyong

    2016-09-01

    Polyamidoamine (PAMAM)-entrapped Au nanoparticles were synthesized with distinct sizes to figure out the size effect of Au-based contrast agent on CT imaging of passively targeted tissues. Au/PAMAM nanoparticles were first synthesized with narrow distribution of particles size of 22.2 ± 3.1, 54.2 ± 3.7, and 104.9 ± 4.7 nm in diameters. Size effect leads no significant difference on X-ray attenuation when Au/PAMAM was ≤0.05 mol/L. For CT imaging of a tumor model, small Au/PAMAM were more easily internalized via endocytosis in the liver, leading to more obviously enhanced contrast. Similarly, contrast agents with small sizes were more effective in tumor imaging because of the enhanced permeability and retention effect. Overall, the particle size of Au/PAMAM heavily affected the efficiency of CT enhancement in imaging RES and tumors.

  17. Golden carbon nanotubes as multimodal photoacoustic and photothermal high-contrast molecular agents

    PubMed Central

    Kim, Jin-Woo; Galanzha, Ekaterina I.; Shashkov, Evgeny V.; Moon, Hyung-Mo; Zharov, Vladimir P.

    2012-01-01

    Carbon nanotubes have shown promise as contrast agents for photoacoustic and photothermal imaging of tumours and infections because they offer high resolution and allow deep tissue imaging. However, in vivo applications have been limited by the relatively low absorption displayed by nanotubes at near-infrared wavelengths and concerns over toxicity. Here, we show that gold-plated carbon nanotubes—termed golden carbon nanotubes—can be used as photoacoustic and photothermal contrast agents with enhanced near-infrared contrast (~102-fold) for targeting lymphatic vessels in mice using extremely low laser fluence levels of a few mJ cm−2. Antibody-conjugated golden carbon nanotubes were used to map the lymphatic endothelial receptor, and preliminary in vitro viability tests show golden carbon nanotubes have minimal toxicity. This new nanomaterial could be an effective alternative to existing nanoparticles and fluorescent labels for non-invasive targeted imaging of molecular structures in vivo. PMID:19809462

  18. Antibiofouling polymer coated gold nanoparticles as a dual modal contrast agent for X-ray and photoacoustic imaging

    NASA Astrophysics Data System (ADS)

    Huang, Guojia; Yuan, Yi; Xing, Da

    2011-01-01

    X-ray is one of the most useful diagnostic tools in hospitals in terms of frequency of use and cost, while photoacoustic (PA) imaging is a rapidly emerging non-invasive imaging technology that integrates the merits of high optical contrast with high ultrasound resolution. In this study, for the first time, we used gold nanoparticles (GNPs) as a dual modal contrast agent for X-ray and PA imaging. Soft gelatin phantoms with embedded tumor simulators of GNPs in various concentrations are clearly shown in both X-ray and PA imaging. With GNPs as a dual modal contrast agent, X-ray can fast detect the position of tumor and provide morphological information, whereas PA imaging has important potential applications in the image guided therapy of superficial tumors such as breast cancer, melanoma and Merkel cell carcinoma.

  19. Reference tissue quantification of DCE-MRI data without a contrast agent calibration

    NASA Astrophysics Data System (ADS)

    Walker-Samuel, Simon; Leach, Martin O.; Collins, David J.

    2007-02-01

    The quantification of dynamic contrast-enhanced (DCE) MRI data conventionally requires a conversion from signal intensity to contrast agent concentration by measuring a change in the tissue longitudinal relaxation rate, R1. In this paper, it is shown that the use of a spoiled gradient-echo acquisition sequence (optimized so that signal intensity scales linearly with contrast agent concentration) in conjunction with a reference tissue-derived vascular input function (VIF), avoids the need for the conversion to Gd-DTPA concentration. This study evaluates how to optimize such sequences and which dynamic time-series parameters are most suitable for this type of analysis. It is shown that signal difference and relative enhancement provide useful alternatives when full contrast agent quantification cannot be achieved, but that pharmacokinetic parameters derived from both contain sources of error (such as those caused by differences between reference tissue and region of interest proton density and native T1 values). It is shown in a rectal cancer study that these sources of uncertainty are smaller when using signal difference, compared with relative enhancement (15 ± 4% compared with 33 ± 4%). Both of these uncertainties are of the order of those associated with the conversion to Gd-DTPA concentration, according to literature estimates.

  20. Thermal dependence of ultrasound contrast agents scattering efficiency for echographic imaging techniques

    NASA Astrophysics Data System (ADS)

    Biagioni, Angelo; Bettucci, Andrea; Passeri, Daniele; Alippi, Adriano

    2015-06-01

    Ultrasound contrast agents are used in echographic imaging techniques to enhance image contrast. In addition, they may represent an interesting solution to the problem of non-invasive temperature monitoring inside the human body, based on some thermal variations of their physical properties. Contrast agents, indeed, are inserted into blood circulation and they reach the most important organs inside the human body; consequently, any thermometric property that they may possess, could be exploited for realizing a non-invasive thermometer. They essentially are a suspension of microbubbles containing a gas enclosed in a phospholipid membrane; temperature variations induce structural modifications of the microbubble phospholipid shell, thus causing thermal dependence of contrast agent's elastic characteristics. In this paper, the acoustic scattering efficiency of a bulk suspension of of SonoVue® (Bracco SpA Milan, Italy) has been studied using a pulse-echo technique in the frequency range 1-17 MHz, as it depends upon temperatures between 25 and 65°C. Experimental data confirm that the ultrasonic attenuation coefficient of SonoVue® depends on temperature between 25 and 60°C. Chemical composition of the bubble shell seem to support the hypothesis that a phase transition in the microstructure of lipid-coated microbubbles could play a key role in explaining such effect.

  1. Self-assembled nanomaterials for photoacoustic imaging

    NASA Astrophysics Data System (ADS)

    Wang, Lei; Yang, Pei-Pei; Zhao, Xiao-Xiao; Wang, Hao

    2016-01-01

    In recent years, extensive endeavors have been paid to construct functional self-assembled nanomaterials for various applications such as catalysis, separation, energy and biomedicines. To date, different strategies have been developed for preparing nanomaterials with diversified structures and functionalities via fine tuning of self-assembled building blocks. In terms of biomedical applications, bioimaging technologies are urgently calling for high-efficient probes/contrast agents for high-performance bioimaging. Photoacoustic (PA) imaging is an emerging whole-body imaging modality offering high spatial resolution, deep penetration and high contrast in vivo. The self-assembled nanomaterials show high stability in vivo, specific tolerance to sterilization and prolonged half-life stability and desirable targeting properties, which is a kind of promising PA contrast agents for biomedical imaging. Herein, we focus on summarizing recent advances in smart self-assembled nanomaterials with NIR absorption as PA contrast agents for biomedical imaging. According to the preparation strategy of the contrast agents, the self-assembled nanomaterials are categorized into two groups, i.e., the ex situ and in situ self-assembled nanomaterials. The driving forces, assembly modes and regulation of PA properties of self-assembled nanomaterials and their applications for long-term imaging, enzyme activity detection and aggregation-induced retention (AIR) effect for diagnosis and therapy are emphasized. Finally, we conclude with an outlook towards future developments of self-assembled nanomaterials for PA imaging.

  2. Synthesis of nanostructured barium phosphate and its application in micro-computed tomography of mouse brain vessels in ex vivo

    NASA Astrophysics Data System (ADS)

    Zhu, Bangshang; Yuan, Falei; Yuan, Xiaoya; Bo, Yang; Wang, Yongting; Yang, Guo-Yuan; Drummen, Gregor P. C.; Zhu, Xinyuan

    2014-02-01

    Micro-computed tomography (micro-CT) is a powerful tool for visualizing the vascular systems of tissues, organs, or entire small animals. Vascular contrast agents play a vital role in micro-CT imaging in order to obtain clear and high-quality images. In this study, a new kind of nanostructured barium phosphate was fabricated and used as a contrast agent for ex vivo micro-CT imaging of blood vessels in the mouse brain. Nanostructured barium phosphate was synthesized through a simple wet precipitation method using Ba(NO3)2, and (NH4)2HPO4 as starting materials. The physiochemical properties of barium phosphate were characterized by scanning electron microscopy, transmission electron microscopy, X-ray diffraction, Fourier transform infrared spectroscopy, and thermal analysis. Furthermore, the impact of the produced nanostructures on cell viability was evaluated via the MTT assay, which generally showed low to moderate cytotoxicity. Finally, the animal test images demonstrated that the use of nanostructured barium phosphate as a contrast agent in Micro-CT imaging produced sharp images with excellent contrast. Both major vessels and the microvasculature were clearly observable in the imaged mouse brain. Overall, the results indicate that nanostructured barium phosphate is a potential and useful vascular contrast agent for micro-CT imaging.

  3. Self-assembled nanomaterials for photoacoustic imaging.

    PubMed

    Wang, Lei; Yang, Pei-Pei; Zhao, Xiao-Xiao; Wang, Hao

    2016-02-07

    In recent years, extensive endeavors have been paid to construct functional self-assembled nanomaterials for various applications such as catalysis, separation, energy and biomedicines. To date, different strategies have been developed for preparing nanomaterials with diversified structures and functionalities via fine tuning of self-assembled building blocks. In terms of biomedical applications, bioimaging technologies are urgently calling for high-efficient probes/contrast agents for high-performance bioimaging. Photoacoustic (PA) imaging is an emerging whole-body imaging modality offering high spatial resolution, deep penetration and high contrast in vivo. The self-assembled nanomaterials show high stability in vivo, specific tolerance to sterilization and prolonged half-life stability and desirable targeting properties, which is a kind of promising PA contrast agents for biomedical imaging. Herein, we focus on summarizing recent advances in smart self-assembled nanomaterials with NIR absorption as PA contrast agents for biomedical imaging. According to the preparation strategy of the contrast agents, the self-assembled nanomaterials are categorized into two groups, i.e., the ex situ and in situ self-assembled nanomaterials. The driving forces, assembly modes and regulation of PA properties of self-assembled nanomaterials and their applications for long-term imaging, enzyme activity detection and aggregation-induced retention (AIR) effect for diagnosis and therapy are emphasized. Finally, we conclude with an outlook towards future developments of self-assembled nanomaterials for PA imaging.

  4. X-ray computed tomography imaging of a tumor with high sensitivity using gold nanoparticles conjugated to a cancer-specific antibody via polyethylene glycol chains on their surface

    NASA Astrophysics Data System (ADS)

    Nakagawa, Tomohiko; Gonda, Kohsuke; Kamei, Takashi; Cong, Liman; Hamada, Yoh; Kitamura, Narufumi; Tada, Hiroshi; Ishida, Takanori; Aimiya, Takuji; Furusawa, Naoko; Nakano, Yasushi; Ohuchi, Noriaki

    2016-01-01

    Contrast agents are often used to enhance the contrast of X-ray computed tomography (CT) imaging of tumors to improve diagnostic accuracy. However, because the iodine-based contrast agents currently used in hospitals are of low molecular weight, the agent is rapidly excreted from the kidney or moves to extravascular tissues through the capillary vessels, depending on its concentration gradient. This leads to nonspecific enhancement of contrast images for tissues. Here, we created gold (Au) nanoparticles as a new contrast agent to specifically image tumors with CT using an enhanced permeability and retention (EPR) effect. Au has a higher X-ray absorption coefficient than does iodine. Au nanoparticles were supported with polyethylene glycol (PEG) chains on their surface to increase the blood retention and were conjugated with a cancer-specific antibody via terminal PEG chains. The developed Au nanoparticles were injected into tumor-bearing mice, and the distribution of Au was examined with CT imaging, transmission electron microscopy, and elemental analysis using inductively coupled plasma optical emission spectrometry. The results show that specific localization of the developed Au nanoparticles in the tumor is affected by a slight difference in particle size and enhanced by the conjugation of a specific antibody against the tumor.

  5. Intravenous injection of gadobutrol in an epidemiological study group did not lead to a difference in relative signal intensities of certain brain structures after 5 years.

    PubMed

    Kromrey, Marie-Luise; Liedtke, Kim Rouven; Ittermann, Till; Langner, Sönke; Kirsch, Michael; Weitschies, Werner; Kühn, Jens-Peter

    2017-02-01

    To investigate if application of macrocyclic gadolinium-based contrast agents in volunteers is associated with neuronal deposition detected by magnetic resonance imaging in a 5-year longitudinal survey. Three hundred eighty-seven volunteers who participated in a population-based study were enrolled. Subjects underwent plain T1-weighted brain MRI at baseline and 5 years later with identical sequence parameters. At baseline, 271 participants additionally received intravenous injection of the macrocyclic contrast agent gadobutrol (0.15 mmol/kg). A control group including 116 subjects received no contrast agent. Relative signal intensities of thalamus, pallidum, pons and dentate nucleus were compared at baseline and follow-up. No difference in relative signal intensities was observed between contrast group (thalamus, p = 0.865; pallidum, p = 0.263; pons, p = 0.533; dentate nucleus, p = 0.396) and control group (thalamus, p = 0.683; pallidum; p = 0.970; pons, p = 0.773; dentate nucleus, p = 0.232) at both times. Comparison between both groups revealed no significant differences in relative signal intensities (thalamus, p = 0.413; pallidum, p = 0.653; pons, p = 0.460; dentate nucleus, p = 0.751). The study showed no significant change in globus pallidus-to-thalamus or dentate nucleus-to-pons ratios. Five years after administration of a 1.5-fold dose gadobutrol to normal subjects, signal intensity of thalamus, pallidum, pons and dentate nucleus did not differ from participants who had not received gadobutrol. • Gadobutrol does not lead to neuronal signal alterations after 5 years. • Neuronal deposition of macrocyclic contrast agent could not be confirmed. • Macrocyclic contrast agents in a proven dosage are safe.

  6. Use of trimetasphere metallofullerene MRI contrast agent for the non-invasive longitudinal tracking of stem cells in the lung

    PubMed Central

    Murphy, Sean V.; Hale, Austin; Reid, Tanya; Olson, John; Kidiyoor, Amritha; Tan, Josh; Zhou, Zhiguo; Jackson, John; Atala, Anthony

    2016-01-01

    Magnetic Resonance Imaging (MRI) is a commonly used, non-invasive imaging technique that provides visualization of soft tissues with high spatial resolution. In both a research and clinical setting, the major challenge has been identifying a non-invasive and safe method for longitudinal tracking of delivered cells in vivo. The labeling and tracking of contrast agent labeled cells using MRI has the potential to fulfill this need. Contrast agents are often used to enhance the image contrast between the tissue of interest and surrounding tissues with MRI. The most commonly used MRI contrast agents contain Gd(III) ions. However, Gd(III) ions are highly toxic in their ionic form, as they tend to accumulate in the liver, spleen, kidney and bones and block calcium channels. Endohedral metallofullerenes such as trimetallic nitride endohedral metallofullerenes (Trimetasphere®) are one unique class of fullerene molecules where a Gd3N cluster is encapsulated inside a C80 carbon cage referred to as Gd3N@C80. These endohedral metallofullerenes have several advantages over small chelated Gd(III) complexes such as increased stability of the Gd(III) ion, minimal toxic effects, high solubility in water and high proton relativity. In this study, we describe the evaluation of gadolinium-based Trimetasphere® positive contrast agent for the in vitro labeling and in vivo tracking of human amniotic fluid-derived stem cells within lung tissue. In addition, we conducted a ‘proof-of-concept’ experiment demonstrating that this methodology can be used to track the homing of stem cells to injured lung tissue and provide longitudinal analysis of cell localization over an extended time course. PMID:26546729

  7. Coronary Computed Tomographic Angiography at Low Concentration of Contrast Agent and Low Tube Voltage in Patients with Obesity:: A Feasibility Study.

    PubMed

    Pan, Yu-Ning; Li, Ai-Jing; Chen, Xiao-Min; Wang, Jian; Ren, Da-Wei; Huang, Qiu-Li

    2016-04-01

    Using lower tube voltage can reduce the exposure to radiation and the dose of contrast agent. However, lower tube voltage is often linked to more noise and poor image quality, which create a need for more effective technology to resolve this problem. To explore the feasibility of coronary computed tomographic angiography (CCTA) in patients with obesity at low tube voltage (100 kV) and low contrast agent concentration (270 mg/mL) using iterative reconstruction. A total of 48 patients with body mass index greater than 30 kg/m(2) were included and randomly divided into two groups. Group A received a traditional protocol (iopromide 370 mg/mL + 120 kV); group B received a protocol with low tube voltage (100 kV), low contrast agent concentration (270 mg/mL), and iterative reconstruction. The effective dose (ED), average attenuation values, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), the figure of merit (FOM), image quality scores, and the total iodine intake were compared. No significant differences in average CT attenuations, SNR, CNR, and subjective scores were noticed between the two groups (P > 0.05), whereas the FOM of group B was significantly higher than that of group A. Effective radiation dose, total iodine, and iodine injection rate in group B were lower than those of group A (P <0.01). In patients with obesity, isotonic contrast agent with low iodine concentration and low-dose CCTA were feasible. Substantial reduction in radiation dose and the iodine intake could be achieved without compromising the image quality. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  8. Use of trimetasphere metallofullerene MRI contrast agent for the non-invasive longitudinal tracking of stem cells in the lung.

    PubMed

    Murphy, Sean V; Hale, Austin; Reid, Tanya; Olson, John; Kidiyoor, Amritha; Tan, Josh; Zhou, Zhiguo; Jackson, John; Atala, Anthony

    2016-04-15

    Magnetic Resonance Imaging (MRI) is a commonly used, non-invasive imaging technique that provides visualization of soft tissues with high spatial resolution. In both a research and clinical setting, the major challenge has been identifying a non-invasive and safe method for longitudinal tracking of delivered cells in vivo. The labeling and tracking of contrast agent labeled cells using MRI has the potential to fulfill this need. Contrast agents are often used to enhance the image contrast between the tissue of interest and surrounding tissues with MRI. The most commonly used MRI contrast agents contain Gd(III) ions. However, Gd(III) ions are highly toxic in their ionic form, as they tend to accumulate in the liver, spleen, kidney and bones and block calcium channels. Endohedral metallofullerenes such as trimetallic nitride endohedral metallofullerenes (Trimetasphere®) are one unique class of fullerene molecules where a Gd3N cluster is encapsulated inside a C80 carbon cage referred to as Gd3N@C80. These endohedral metallofullerenes have several advantages over small chelated Gd(III) complexes such as increased stability of the Gd(III) ion, minimal toxic effects, high solubility in water and high proton relativity. In this study, we describe the evaluation of gadolinium-based Trimetasphere® positive contrast agent for the ​in vitro labeling and in vivo tracking of human amniotic fluid-derived stem cells within lung tissue. In addition, we conducted a 'proof-of-concept' experiment demonstrating that this methodology can be used to track the homing of stem cells to injured lung tissue and provide longitudinal analysis of cell localization over an extended time course. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Are iso-osmolar, as compared to low-osmolar, contrast media cost-effective in patients undergoing cardiac catheterization? An economic analysis.

    PubMed

    Hiremath, Swapnil; Akbari, Ayub; Wells, George A; Chow, Benjamin J W

    2018-04-23

    Contrast-induced acute kidney injury is a prominent complication following cardiac catheterization, though the risk has progressively decreased in recent times with appropriate risk stratification and use of safer contrast agents. Despite data supporting further lowering of risk with the iso-osmolar agent, iodixanol, uptake has lagged, perhaps due to increased upfront cost of this agent. We undertook an economic analysis to estimate the cost-effectiveness of a strategy utilizing iodixanol compared to using a low-osmolar contrast agent. We created a Markov model to evaluate the two strategies, and included a differential relative risk of contrast-induced acute kidney injury, based on a systematic review of the literature. Downstream clinical events, including need for dialysis and mortality, were modeled using data from existing published literature. A third-party payer perspective was utilized for the analysis and presentation of the primary economic analysis. The strategy of using iodixanol dominated in both the low-risk and high-risk base case analyses. However, the difference was quite small in the low-risk scenario (lifetime cost: C$678,034 vs. C$678,059 and life expectancy: 19.80 vs. 19.72 years). The difference was more marked (life expectancy 15.65 vs. 14.15 years and cost C$680,989 vs. C$682,023) in the high-risk case analysis. This was robust across most of the variables tested in sensitivity analyses. The use of iodixanol, compared with low-osmolar contrast agents, for cardiac catheterization, results in a small benefit clinical outcomes, and in a savings in direct healthcare costs. Overall, our analysis supports the use of iodixanol for cardiac catheterization, especially in patients at high risk of acute kidney injury.

  10. Recent advances in the imaging of hepatocellular carcinoma. From ultrasound to positron emission tomography scan.

    PubMed

    Camaggi, Valeria; Piscaglia, Fabio; Bolondi, Luigi

    2007-07-01

    Recent advances in imaging techniques for hepatocellular carcinoma (HCC) offer the possibility of investigating contrast perfusion of liver nodules in cirrhosis. It is now accepted that a non-invasive diagnosis of HCC can be established based on the vascular pattern obtained with pure blood pool contrast agents. The diagnostic pattern consists of contrast enhancement in the arterial phase, indicative of arterial hypervascularization, followed by contrast wash out in the portal and late phases, which leads the nodule to show the same, or, more specifically, a lower contrast signal than the surrounding parenchyma. Such patterns can be obtained by CT, MRI and, more recently, by real time Contrast Enhanced Ultrasonography with second-generation ultrasound contrast agents. A typical vascular pattern in a nodule perceptible also without contrast is highly specific for HCC, so that non-invasive diagnostic algorithms have been developed and recently updated.

  11. MRI and CT contrast media extravasation

    PubMed Central

    Heshmatzadeh Behzadi, Ashkan; Farooq, Zerwa; Newhouse, Jeffery H.; Prince, Martin R.

    2018-01-01

    Abstract Background: This systematic review combines data from multiple papers on contrast media extravasation to identify factors contributing to increased extravasation risk. Methods: Data were extracted from 17 papers reporting 2191 extravasations in 1,104,872 patients (0.2%) undergoing computed tomography (CT) or magnetic resonance imaging (MRI). Results: Extravasation rates were 0.045% for gadolinium-based contrast agents (GBCA) and nearly 6-fold higher, 0.26% for iodinated contrast agents. Factors associated with increased contrast media extravasations included: older age, female gender, using an existing intravenous (IV) instead of placing a new IV in radiology, in-patient status, use of automated power injection, high injection rates, catheter location, and failing to warm up the more viscous contrast media to body temperature. Conclusion: Contrast media extravasation is infrequent but nearly 6 times less frequent with GBCA for MRI compared with iodinated contrast used in CT. PMID:29489663

  12. The attribution of navigational- and goal-directed agency in dogs (Canis familiaris) and human toddlers (Homo sapiens).

    PubMed

    Tauzin, Tibor; Csík, Andor; Lovas, Kata; Gergely, György; Topál, József

    2017-02-01

    Both human infants and nonhuman primates can recognize unfamiliar entities as instrumental agents ascribing to them goals and efficiency of goal-pursuit. This competence relies on movement cues indicating distal sensitivity to the environment and choice of efficient goal-approach. Although dogs' evolved sensitivity to social cues allow them to recognize humans as communicative agents, it remains unclear whether they have also evolved a basic concept of instrumental agency. We used a preferential object-choice procedure to test whether adult pet dogs and human toddlers can identify unfamiliar entities as agents based on different types of movement cues that specify different levels of agency. In the navigational agency condition, dogs preferentially chose an object that modified its pathway to avoid collision with obstacles over another object showing no evidence of distal sensitivity (regularly bumping into obstacles). However, in the goal-efficiency condition where neither object collided with obstacles as it navigated toward a distal target, but only 1 of them exhibited efficient goal-approach as well, toddlers, but not dogs, showed a preference toward the efficient goal-directed agent. These findings indicate that dogs possess a limited concept of environmentally sensitive navigational agency that they attribute to self-propelled entities capable of modifying their movement to avoid colliding with obstacles. Toddlers, in contrast, demonstrated clear sensitivity to cues of efficient variability of goal-approach as the basis for differentiating, attributing, and showing preference for goal-directed instrumental agency. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  13. A smart magnetic resonance imaging contrast agent responsive to adenosine based on a DNA aptamer-conjugated gadolinium complex.

    PubMed

    Xu, Weichen; Lu, Yi

    2011-05-07

    We report a general strategy for developing a smart MRI contrast agent for the sensing of small molecules such as adenosine based on a DNA aptamer that is conjugated to a Gd compound and a protein streptavidin. The binding of adenosine to its aptamer results in the dissociation of the Gd compound from the large protein, leading to decreases in the rotational correlation time and thus change of MRI contrast. © The Royal Society of Chemistry 2011

  14. Screening and Monitoring Response to Treatment Using Subsecond Molecular Imaging and Hyperpolarized Contrast Agents

    DTIC Science & Technology

    2013-05-01

    Magnetization transfer MRI in multiple sclerosis . J Neuroimaging. 2007;17 Suppl 1:S22–S26. 82. Filippi M, Rocca MA. Magnetization transfer magnetic resonance... multiple sclerosis . Neuroimaging Clin N Am. 2009;19(1):27–36. 84. Lundbom N. Determination of magnetization transfer contrast in tissue: an MR... multiple RF coils intended for optimal direct and indirect detection of hyperpolarized contrast agents in vivo. 4.b. Y1Q3-Y1Q4. Low field MRI: pre

  15. Using T2-Exchange from Ln3+DOTA-Based Chelates for Contrast-Enhanced Molecular Imaging of Prostate Cancer with MRI

    DTIC Science & Technology

    2015-04-01

    antigen ( PSMA ) of prostate cancer cells would then be synthesized and tested with both in vitro and in vivo experiments. Major Findings: We found that the...simplified chemistry. 15. SUBJECT TERMS MRI Contrast Agent, T2 contrast, Prostate Cancer, PSMA Targeted Agent, Early Detection and Diagnosis, Dysprosium... PSMA ), which is significantly over-expressed by prostate cancer cells, has proven to be an excellent target for imaging prostate cancer in mouse

  16. Liver Masses: What Physicians Need to Know About Ordering and Interpreting Liver Imaging.

    PubMed

    Sheybani, Arman; Gaba, Ron C; Lokken, R Peter; Berggruen, Senta M; Mar, Winnie A

    2017-10-18

    This paper reviews diagnostic imaging techniques used to characterize liver masses and the imaging characteristics of the most common liver masses. The role of recently adopted ultrasound and magnetic resonance imaging contrast agents will be emphasized. Contrast-enhanced ultrasound is an inexpensive exam which can confirm benignity of certain liver masses without ionizing radiation. Magnetic resonance imaging using hepatocyte-specific gadolinium-based contrast agents can help confirm or narrow the differential diagnosis of liver masses.

  17. Dual-Energy Micro-CT Functional Imaging of Primary Lung Cancer in Mice Using Gold and Iodine Nanoparticle Contrast Agents: A Validation Study

    PubMed Central

    Ashton, Jeffrey R.; Clark, Darin P.; Moding, Everett J.; Ghaghada, Ketan; Kirsch, David G.; West, Jennifer L.; Badea, Cristian T.

    2014-01-01

    Purpose To provide additional functional information for tumor characterization, we investigated the use of dual-energy computed tomography for imaging murine lung tumors. Tumor blood volume and vascular permeability were quantified using gold and iodine nanoparticles. This approach was compared with a single contrast agent/single-energy CT method. Ex vivo validation studies were performed to demonstrate the accuracy of in vivo contrast agent quantification by CT. Methods Primary lung tumors were generated in LSL-KrasG12D; p53FL/FL mice. Gold nanoparticles were injected, followed by iodine nanoparticles two days later. The gold accumulated in tumors, while the iodine provided intravascular contrast. Three dual-energy CT scans were performed–two for the single contrast agent method and one for the dual contrast agent method. Gold and iodine concentrations in each scan were calculated using a dual-energy decomposition. For each method, the tumor fractional blood volume was calculated based on iodine concentration, and tumor vascular permeability was estimated based on accumulated gold concentration. For validation, the CT-derived measurements were compared with histology and inductively-coupled plasma optical emission spectroscopy measurements of gold concentrations in tissues. Results Dual-energy CT enabled in vivo separation of gold and iodine contrast agents and showed uptake of gold nanoparticles in the spleen, liver, and tumors. The tumor fractional blood volume measurements determined from the two imaging methods were in agreement, and a high correlation (R2 = 0.81) was found between measured fractional blood volume and histology-derived microvascular density. Vascular permeability measurements obtained from the two imaging methods agreed well with ex vivo measurements. Conclusions Dual-energy CT using two types of nanoparticles is equivalent to the single nanoparticle method, but allows for measurement of fractional blood volume and permeability with a single scan. As confirmed by ex vivo methods, CT-derived nanoparticle concentrations are accurate. This method could play an important role in lung tumor characterization by CT. PMID:24520351

  18. Prostate-specific membrane antigen targeted protein contrast agents for molecular imaging of prostate cancer by MRI†

    PubMed Central

    Pu, Fan; Salarian, Mani; Xue, Shenghui; Qiao, Jingjuan; Feng, Jie; Tan, Shanshan; Patel, Anvi; Li, Xin; Mamouni, Kenza; Hekmatyar, Khan; Zou, Juan; Wu, Daqing

    2017-01-01

    Prostate-specific membrane antigen (PSMA) is one of the most specific cell surface markers for prostate cancer diagnosis and targeted treatment. However, achieving molecular imaging using non-invasive MRI with high resolution has yet to be achieved due to the lack of contrast agents with significantly improved relaxivity for sensitivity, targeting capabilities and metal selectivity. We have previously reported our creation of a novel class of protein Gd3+ contrast agents, ProCA32, which displayed significantly improved relaxivity while exhibiting strong Gd3+ binding selectivity over physiological metal ions. In this study, we report our effort in further developing biomarker-targeted protein MRI contrast agents for molecular imaging of PSMA. Among three PSMA targeted contrast agents engineered with addition of different molecular recognition sequences, ProCA32.PSMA exhibits a binding affinity of 1.1 ± 0.1 μM for PSMA while the metal binding affinity is maintained at 0.9 ± 0.1 × 10−22 M. In addition, ProCA32.PSMA exhibits r1 of 27.6 mM−1 s−1 and r2 of 37.9 mM−1 s−1 per Gd (55.2 and 75.8 mM−1 s−1 per molecule r1 and r2, respectively) at 1.4 T. At 7 T, ProCA32.PSMA also has r2 of 94.0 mM−1 s−1 per Gd (188.0 mM−1 s−1 per molecule) and r1 of 18.6 mM−1 s−1 per Gd (37.2 mM−1 s−1 per molecule). This contrast capability enables the first MRI enhancement dependent on PSMA expression levels in tumor bearing mice using both T1 and T2-weighted MRI at 7 T. Further development of these PSMA-targeted contrast agents are expected to be used for the precision imaging of prostate cancer at an early stage and to monitor disease progression and staging, as well as determine the effect of therapeutic treatment by non-invasive evaluation of the PSMA level using MRI. PMID:26961235

  19. WE-H-207A-08: Characterization of a Broad-Spectrum Cancer Targeted MRI Contrast Agent

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brunnquell, C; Zhang, R; Pinchuk, A

    Purpose: To characterize the relaxation properties and tumor targeting capabilities of a novel alkylphosphocholine (APC) analog MR contrast agent, Gd-DO3A-404. Methods: Relaxivities were measured via T1 and T2 mapping of Gd-DO3A-404 with inversion recovery and spin echo pulse sequences, respectively. Uptake was characterized in flank xenograft models of non-small cell lung cancer (A549) and glioma (U87) and compared with uptake of Dotarem. Mice (N=3 per model per agent) were delivered 2.34 moles contrast intravenously. T1-weighted MRI and T1 maps were acquired pre-contrast and at multiple time points up to seven days post-contrast. For Dotarem imaging, T1-weighted MRI was performed atmore » multiple time points from one minute to one day. Results: Relaxivities of Gd-DO3A-404 in plasma were r1=5.74 and r2=20.4 s-1/mm at 4.7T, comparing favorably to clinical contrast agent Dotarem (r1=3.3, r2=4.7). Specific, sustained uptake of Gd-DO3A-404 was observed in U87 and A549. The ratio of tumor:muscle T1-weighted signal increased from 1.24 pre-contrast to 2.12 twenty-four hours post-contrast in U87 and from 1.14 to 2.16 (same time points) in A549. Significant signal enhancement was maintained until 7 and 4 days post-contrast in U87 and A549, respectively. In comparison, uptake and washout of Dotarem in U87 occurred over the course of fifteen minutes. The ratio of tumor:muscle T1-weighted signal increased only 59% as much as Gd-DO3A-404, ranging from 1.15 pre-contrast to a maximum of 1.67 five minutes post-contrast. Significant signal enhancement from Dotarem was not sustained beyond one hour post-contrast. Conclusion: These results indicate that with favorable relaxation characteristics and sustained signal-enhancing uptake in multiple tumor models, Gd-DO3A-404 has great potential as a tumor-targeting MR contrast agent. As part of a library of APC analogs labeled with PET/optical tracers and therapeutic radionuclides, Gd-DO3A-404 further expands theranostic capabilities. Future work will investigate applications in orthotopic glioma imaging, simultaneous PET/MR, and neutron capture therapy.« less

  20. Investigation of a potential macromolecular MRI contrast agent prepared from PPI (G = 2, polypropyleneimine, generation 2) dendrimer bifunctional chelates

    NASA Astrophysics Data System (ADS)

    Wang, Jianxin Steven

    The long-term objective is to develop magnetic resonance (MR) contrast agents that actively and passively target tumors for diagnosis and therapy. Many diagnostic imaging techniques for cancer lack specificity. A dendrimer based magnetic resonance imaging contrast agent has been developed with large proton relaxation enhancements and high molecular relaxivities. A new type of linear dendrimer based MRI contrast agent that is built from the polypropyleneimine and polyamidoamine dendrimers in which free amines have been conjugated to the chelate DTPA, which further formed the complex with Gadolinium (Gd) was studied. The specific research goals were to test the hypothesis that a linear chelate with macromolecular agents can be used in vitro and in vivo. This work successfully examined the adequacy and viability of the application for this agent in vitro and in vivo. A small animal whole body counter was designed and constructed to allow us to monitor biodistribution and kinetic mechanisms using a radioisotope labeled complex. The procedures of metal labeling, separation and purification have been established from this work. A biodistribution study has been performed using radioisotope induced organ/tissue counting and gamma camera imaging. The ratio of percentage of injected dose per gram organ/tissue for kidney and liver is 3.71 from whole body counter and 3.77 from the gamma camera. The results suggested that retention of Gd (III) is too high and a more kinetically stable chelate should be developed. The pharmacokinetic was evaluated in the whole animal model with the whole body clearance, and a kinetics model was developed. The pharmacokinetic results showed a bi-exponential decay in the animal model with two component excretion constants 1.43e(-5) and 0.0038511, which give half-lives of 3 hours and 33.6 days, respectively. Magnetic resonance imaging of this complex resulted in a 52% contrast enhancement in the rat kidney following the agents' administration in vivo.

  1. Use of Radiocontrast Agents in CKD and ESRD.

    PubMed

    Bahrainwala, Jehan Z; Leonberg-Yoo, Amanda K; Rudnick, Michael R

    2017-07-01

    Contrast exposure in a population with chronic kidney disease (CKD) requires additional consideration given the risk of contrast-induced nephropathy (CIN) after exposure to iodinated contrast as well as systemic injury with exposure to gadolinium-based contrast agents (GBCA). Strategies to avoid CIN, and manage patients after exposure, including extracorporeal removal of contrast media, may differ among an advanced CKD population as compared to a general population. There is strong evidence to support the use of isotonic volume expansion and the lowest dose of low-osmolar or iso-osmolar contrast media possible to decrease CIN. The current literature on other newer prophylactic strategies such as statins, remote ischemic preconditioning, discontinuation of renin angiotensin aldosterone system (RAAS) blockade, and RenalGuard is limited thus these strategies cannot currently be recommended as routine prophylaxis for CIN. The use of extracorporeal removal of contrast agents as prophylaxis to reduce CIN has been the subject of multiple studies; however, data do not support a beneficial effect in reduction in CIN. Immediate removal of contrast by dialysis in a maintenance dialysis population is also not recommended, unless an individual's cardiopulmonary status is dependent on strict volume management. In patients with reduced renal function, GCBA exposure increases the risk of NSF. In patients with AKI, CKD stage 3 or greater (eGFR <30 ml/minute/1.73 m 2 ), or patients on dialysis, we do not recommend the use of GBCA and alternative imaging modalities should be considered. If patients absolutely need magnetic resonance imaging with GBCA, we recommend the use of the lowest dose possible of the newer macrocylic, ionic agents (gadoterate meglumine) as well as immediate postprocedural HD in patients already on HD or peritoneal dialysis or with stage 5 CKD and with a functioning dialysis access already in place. © 2017 Wiley Periodicals, Inc.

  2. Comparison of arterial input functions measured from ultra-fast dynamic contrast enhanced MRI and dynamic contrast enhanced computed tomography in prostate cancer patients

    NASA Astrophysics Data System (ADS)

    Wang, Shiyang; Lu, Zhengfeng; Fan, Xiaobing; Medved, Milica; Jiang, Xia; Sammet, Steffen; Yousuf, Ambereen; Pineda, Federico; Oto, Aytekin; Karczmar, Gregory S.

    2018-02-01

    The purpose of this study was to evaluate the accuracy of arterial input functions (AIFs) measured from dynamic contrast enhanced (DCE) MRI following a low dose of contrast media injection. The AIFs measured from DCE computed tomography (CT) were used as ‘gold standard’. A total of twenty patients received CT and MRI scans on the same day. Patients received 120 ml Iohexol in DCE-CT and a low dose of (0.015 mM kg-1) of gadobenate dimeglumine in DCE-MRI. The AIFs were measured in the iliac artery and normalized to the CT and MRI contrast agent doses. To correct for different temporal resolution and sampling periods of CT and MRI, an empirical mathematical model (EMM) was used to fit the AIFs first. Then numerical AIFs (AIFCT and AIFMRI) were calculated based on fitting parameters. The AIFMRI was convolved with a ‘contrast agent injection’ function (AIFMRICON ) to correct for the difference between MRI and CT contrast agent injection times (~1.5 s versus 30 s). The results show that the EMMs accurately fitted AIFs measured from CT and MRI. There was no significant difference (p  >  0.05) between the maximum peak amplitude of AIFs from CT (22.1  ±  4.1 mM/dose) and MRI after convolution (22.3  ±  5.2 mM/dose). The shapes of the AIFCT and AIFMRICON were very similar. Our results demonstrated that AIFs can be accurately measured by MRI following low dose contrast agent injection.

  3. 78 FR 77471 - Prospective Grant of Exclusive License for: Convection Enhanced Delivery of a Therapeutic Agent...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-23

    ...-toxic macromolecular MRI contrast agents such as chelated Gd(III). These macromolecular imaging agents... Exclusive License for: Convection Enhanced Delivery of a Therapeutic Agent With a Surrogate Tracer for... Enhanced Delivery of Therapeutic Agents'', U.S. Provisional Patent Application 60/413,673 (filed September...

  4. Evaluation of Eu(II) -based positive contrast enhancement after intravenous, intraperitoneal, and subcutaneous injections.

    PubMed

    Ekanger, Levi A; Polin, Lisa A; Shen, Yimin; Haacke, E Mark; Allen, Matthew J

    2016-07-01

    Eu(II) -based contrast agents offer physiologically relevant, metal-based redox sensing that is unachievable with Gd(III) -based contrast agents. To evaluate the in vivo contrast enhancement of Eu(II) as a function of injection type, we performed intravenous, intraperitoneal, and subcutaneous injections in mice. Our data reveal a correlation between reported oxygen content and expected rates of diffusion with the persistence of Eu(II) -based contrast enhancement. Biodistribution studies revealed europium clearance through the liver and kidneys for intravenous and intraperitoneal injections, but no contrast enhancement was observed in organs associated with clearance. These data represent a step toward understanding the behavior of Eu(II) -based complexes in vivo. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  5. Imaging efficiency of an X-ray contrast agent-incorporated polymeric microparticle.

    PubMed

    Ahn, Sungsook; Jung, Sung Yong; Lee, Jin Pyung; Lee, Sang Joon

    2011-01-01

    Biocompatible polymeric encapsulants have been widely used as a delivery vehicle for a variety of drugs and imaging agents. In this study, X-ray contrast agent (iopamidol) is encapsulated into a polymeric microparticle (polyvinyl alcohol) as a particulate flow tracer in synchrotron X-ray imaging system. The physical properties of the designed microparticles are investigated and correlated with enhancement in the imaging efficiency by experimental observation and theoretical interpretation. The X-ray absorption ability of the designed microparticle is assessed by Beer-Lambert-Bouguer law. Particle size, either in dried state or in solvent, primarily dominates the X-ray absorption ability under the given condition, thus affecting imaging efficiency of the designed X-ray contrast flow tracers. Copyright © 2011 John Wiley & Sons, Ltd.

  6. Semiconducting polymer dot as a highly effective contrast agent for photoacoustic imaging

    NASA Astrophysics Data System (ADS)

    Yuan, Zhen; Zhang, Jian

    2018-02-01

    In this study, we developed a novel PIID-DTBT based semiconducting polymer dots (Pdots) that have broad and strong optical absorption in the visible-light region (500 nm - 700 nm). Gold nanoparticles (GNPs) and gold nanorods (GNRs) that have been verified as an excellent photoacoustic contrast agent were compared with Pdots based on photoacoustic imaging method. Both ex vivo and in vivo experiment demonstrated Pdots have a better photoacoustic conversion efficiency at 532 nm than GNPs and similar photoacoustic performance with GNRs at 700 nm at the same mass concentration. Our work demonstrates the great potential of Pdots as a highly effective contrast agent for precise localization of lesions relative to the blood vessels based on photoacoustic tomography imaging.

  7. Engineering Gd-loaded nanoparticles to enhance MRI sensitivity via T1 shortening

    NASA Astrophysics Data System (ADS)

    Bruckman, Michael A.; Yu, Xin; Steinmetz, Nicole F.

    2013-11-01

    Magnetic resonance imaging (MRI) is a noninvasive imaging technique capable of obtaining high-resolution anatomical images of the body. Major drawbacks of MRI are the low contrast agent sensitivity and inability to distinguish healthy tissue from diseased tissue, making early detection challenging. To address this technological hurdle, paramagnetic contrast agents have been developed to increase the longitudinal relaxivity, leading to an increased signal-to-noise ratio. This review focuses on methods and principles that enabled the design and engineering of nanoparticles to deliver contrast agents with enhanced ionic relaxivities. Different engineering strategies and nanoparticle platforms will be compared in terms of their manufacturability, biocompatibility properties, and their overall potential to make an impact in clinical MR imaging.

  8. DrugPath: a database for academic investigators to match oncology molecular targets with drugs in development.

    PubMed

    Shah, Eric D; Fisch, Brandon M A; Arceci, Robert J; Buckley, Jonathan D; Reaman, Gregory H; Sorensen, Poul H; Triche, Timothy J; Reynolds, C Patrick

    2014-05-01

    Academic laboratories are developing increasingly large amounts of data that describe the genomic landscape and gene expression patterns of various types of cancers. Such data can potentially identify novel oncology molecular targets in cancer types that may not be the primary focus of a drug sponsor's initial research for an investigational new drug. Obtaining preclinical data that point toward the potential for a given molecularly targeted agent, or a novel combination of agents requires knowledge of drugs currently in development in both the academic and commercial sectors. We have developed the DrugPath database ( http://www.drugpath.org ) as a comprehensive, free-of-charge resource for academic investigators to identify agents being developed in academics or industry that may act against molecular targets of interest. DrugPath data on molecular targets overlay the Michigan Molecular Interactions ( http://mimi.ncibi.org ) gene-gene interaction map to facilitate identification of related agents in the same pathway. The database catalogs 2,081 drug development programs representing 751 drug sponsors and 722 molecular and genetic targets. DrugPath should assist investigators in identifying and obtaining drugs acting on specific molecular targets for biological and preclinical therapeutic studies.

  9. Biocompatible Nanocomplexes for Molecular Targeted MRI Contrast Agent

    NASA Astrophysics Data System (ADS)

    Chen, Zhijin; Yu, Dexin; Wang, Shaojie; Zhang, Na; Ma, Chunhong; Lu, Zaijun

    2009-07-01

    Accurate diagnosis in early stage is vital for the treatment of Hepatocellular carcinoma. The aim of this study was to investigate the potential of poly lactic acid-polyethylene glycol/gadolinium-diethylenetriamine-pentaacetic acid (PLA-PEG/Gd-DTPA) nanocomplexes using as biocompatible molecular magnetic resonance imaging (MRI) contrast agent. The PLA-PEG/Gd-DTPA nanocomplexes were obtained using self-assembly nanotechnology by incubation of PLA-PEG nanoparticles and the commercial contrast agent, Gd-DTPA. The physicochemical properties of nanocomplexes were measured by atomic force microscopy and photon correlation spectroscopy. The T1-weighted MR images of the nanocomplexes were obtained in a 3.0 T clinical MR imager. The stability study was carried out in human plasma and the distribution in vivo was investigated in rats. The mean size of the PLA-PEG/Gd-DTPA nanocomplexes was 187.9 ± 2.30 nm, and the polydispersity index was 0.108, and the zeta potential was -12.36 ± 3.58 mV. The results of MRI test confirmed that the PLA-PEG/Gd-DTPA nanocomplexes possessed the ability of MRI, and the direct correlation between the MRI imaging intensities and the nano-complex concentrations was observed ( r = 0.987). The signal intensity was still stable within 2 h after incubation of the nanocomplexes in human plasma. The nanocomplexes gave much better image contrast effects and longer stagnation time than that of commercial contrast agent in rat liver. A dose of 0.04 mmol of gadolinium per kilogram of body weight was sufficient to increase the MRI imaging intensities in rat livers by five-fold compared with the commercial Gd-DTPA. PLA-PEG/Gd-DTPA nanocomplexes could be prepared easily with small particle sizes. The nanocomplexes had high plasma stability, better image contrast effect, and liver targeting property. These results indicated that the PLA-PEG/Gd-DTPA nanocomplexes might be potential as molecular targeted imaging contrast agent.

  10. Influence of the timing of cardiac catheterization and amount of contrast media on acute renal failure after cardiac surgery.

    PubMed

    Sadeghi, Mohsen Mirmohammad; Gharipour, Mojgan; Nilforoush, Peiman; Shamsolkotabi, Hamid; Sadeghi, Hamid Mirmohammad; Kiani, Amjad; Sadeghi, Pouya Mirmohammad; Farahmand, Niloufar

    2011-04-01

    There is limited data about the influence of timing of cardiac surgery in relation to diagnostic angiography and/or the impact of the amount of contrast media used during angiography on the occurance of acute renal failure (ARF). Therefore, in the present study the effect of the time interval between diagnostic angiography and cardiac surgery and also the amount of contrast media used during the diagnostic procedure on the incidence of ARF after cardiac surgery was investigated. Data of 1177 patients who underwent different types of cardiac surgeries after cardiac catheterization were prospectively examined. The influence of time interval between cardiac catheterization and surgery as well as the amount of contrast agent on postoperative ARF were assessed using multivariable logistic regression. The patients who progressed to ARF were more likely to have received a higher dose of contrast agent compared to the mean dose. However, the time interval between cardiac surgery and last catheterization was not significantly different between the patients with and without ARF (p = 0.05). Overall, postoperative peak creatinine was highest on day 0, then decreased and remained significantly unchanged after this period. Overall prevalence of acute renal failure during follow-up period had a changeable trend and had the highest rates in days 1 (53.57%) and 6 (52.17%) after surgery. Combined coronary bypass and valve surgery were the strongest predictor of postoperative ARF (OR: 4.976, CI = 1.613-15.355 and p = 0.002), followed by intra-aortic balloon pump insertion (OR: 6.890, CI = 1.482-32.032 and p = 0.009) and usage of higher doses of contrast media agent (OR: 1.446, CI = 1.033-2.025 and p = 0.031). Minimizing the amount of contrast agent has a potential role in reducing the incidence of postoperative ARF in patients undergoing cardiac surgery, but delaying cardiac surgery after exposure to these agents might not have this protective effect.

  11. Towards endometriosis diagnosis by gadofosveset-trisodium enhanced magnetic resonance imaging.

    PubMed

    Schreinemacher, Marc H; Backes, Walter H; Slenter, Jos M; Xanthoulea, Sofia; Delvoux, Bert; van Winden, Larissa; Beets-Tan, Regina G; Evers, Johannes L H; Dunselman, Gerard A J; Romano, Andrea

    2012-01-01

    Endometriosis is defined as the presence of endometrial tissue outside the uterus. It affects 10-15% of women during reproductive age and has a big personal and social impact due to chronic pelvic pain, subfertility, loss of work-hours and medical costs. Such conditions are exacerbated by the fact that the correct diagnosis is made as late as 8-11 years after symptom presentation. This is due to the lack of a reliable non-invasive diagnostic test and the fact that the reference diagnostic standard is laparoscopy (invasive, expensive and not without risks). High-molecular weight gadofosveset-trisodium is used as contrast agent in Magnetic Resonance Imaging (MRI). Since it extravasates from hyperpermeable vessels more easily than from mature blood vessels, this contrast agent detects angiogenesis efficiently. Endometriosis has high angiogenic activity. Therefore, we have tested the possibility to detect endometriosis non-invasively using Dynamic Contrast-Enhanced MRI (DCE-MRI) and gadofosveset-trisodium as a contrast agent in a mouse model. Endometriotic lesions were surgically induced in nine mice by autologous transplantation. Three weeks after lesion induction, mice were scanned by DCE-MRI. Dynamic image analysis showed that the rates of uptake (inwash), persistence and outwash of the contrast agent were different between endometriosis and control tissues (large blood vessels and back muscle). Due to the extensive angiogenesis in induced lesions, the contrast agent persisted longer in endometriotic than control tissues, thus enhancing the MRI signal intensity. DCE-MRI was repeated five weeks after lesion induction, and contrast enhancement was similar to that observed three weeks after endometriosis induction. The endothelial-cell marker CD31 and the pericyte marker α-smooth-muscle-actin (mature vessels) were detected with immunohistochemistry and confirmed that endometriotic lesions had significantly higher prevalence of new vessels (CD31 only positive) than the uterus and control tissues. The diagnostic value of gadofosveset-trisodium to detect endometriosis should be tested in human settings.

  12. MRI contrast agent for targeting glioma: interleukin-13 labeled liposome encapsulating gadolinium-DTPA.

    PubMed

    Liu, Xiaoli; Madhankumar, Achuthamangalam B; Miller, Patti A; Duck, Kari A; Hafenstein, Susan; Rizk, Elias; Slagle-Webb, Becky; Sheehan, Jonas M; Connor, James R; Yang, Qing X

    2016-05-01

    Detection of glioma with MRI contrast agent is limited to cases in which the blood-brain barrier (BBB) is compromised as contrast agents cannot cross the BBB. Thus, an early-stage infiltrating tumor is not detectable. Interleukin-13 receptor alpha 2 (IL-13Rα2), which has been shown to be overexpressed in glioma, can be used as a target moiety. We hypothesized that liposomes conjugated with IL-13 and encapsulating MRI contrast agent are capable of passing through an intact BBB and producing MRI contrast with greater sensitivity. The targeted MRI contrast agent was created by encapsulating Magnevist (Gd-DTPA) into liposomes conjugated with IL-13 and characterized by particle size distribution, cytotoxicity, and MRI relaxivity. MR image intensity was evaluated in the brain in normal mice post injection of Gd-DTPA and IL-13-liposome-Gd-DTPA one day apart. The specificity for glioma detection by IL-13-liposome-Gd-DTPA was demonstrated in an intracranial glioma mouse model and validated histologically. The average size of IL-13-liposome-Gd-DTPA was 137 ± 43 nm with relaxivity of 4.0 ± 0.4 L/mmole-s at 7 Tesla. No significant cytotoxicity was observed with MTS assay and serum chemistry in mice. The MRI signal intensity was enhanced up to 15% post injection of IL-13-liposome-Gd-DTPA in normal brain tissue following a similar time course as that for the pituitary gland outside of the BBB. MRI enhanced by IL-13-liposome-Gd-DTPA detected small tumor masses in addition to those seen with Magnevist-enhanced MRI. IL-13-liposome-Gd-DTPA is able to pass through the uncompromised BBB and detect an early stage glioma that cannot be seen with conventional contrast-enhanced MRI. © The Author(s) 2015. Published by Oxford University Press on behalf of the Society for Neuro-Oncology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  13. Nano-assemblies of cationic mPEG brush block copolymers with gadolinium polyoxotungstate [Gd(W5O18)2]9- form stable, high relaxivity MRI contrast agents.

    PubMed

    Ly, Joanne; Li, Yuhuan; Vu, Mai N; Moffat, Bradford A; Jack, Kevin S; Quinn, John F; Whittaker, Michael R; Davis, Thomas P

    2018-04-19

    Polyoxometalates (POMs) incorporating paramagnetic ions, such as gadolinium, show promise as contrast agents for application in magnetic resonance imaging (MRI). Specifically, [Gd(W5O18)2]9- (denoted as GdWO) has been reported to have a higher relaxivity than commercially available contrast agents, but it's clinical utility has been limited by the intrinsic instability of POMs at physiological pH (7.4). In the current report we present a stability study on neat GdWO and nano-assemblies of block copolymers with GdWO in the pH range 5.0-7.4 to assess their suitability as MRI contrast agents. Neat GdWO only maintained structural stability between pH 5.4 and 6.4, and demonstrated poor MRI contrast at pH 7.4. To address this pH instability, GdWO was self-assembled with cationic mPEG brush block copolymers containing 20 or 40 units derived from the cationic monomer, 2-dimethylaminoethyl methacrylate (DMAEMA). Nano-assemblies with different charge ratios were synthesised and characterised according to their size, stability, contrasting properties and toxicity. The longitudinal relaxivity (r1) of the nano-assemblies was found to be dependent on the charge ratio, but not on the length of the cationic polymer block. Further investigation of PDMAEMA20 nano-assemblies demonstrated that they were stable over the pH range 5.0-7.4, exhibiting a higher r1 than either neat GdWO (2.77 s-1 mM-1) or clinical MRI contrast agent Gd-DTPA (4.1 s-1 mM-1) at pH 7.4. Importantly, the nano-assembly with the lowest charge ratio (0.2), showed the highest r1 (12.1 s-1 mM-1) whilst, stabilising GdWO over the pH range studied, eliciting low toxicity with MDA-MB231 cells.

  14. New generation of magnetic and luminescent nanoparticles for in vivo real-time imaging

    PubMed Central

    Lacroix, Lise-Marie; Delpech, Fabien; Nayral, Céline; Lachaize, Sébastien; Chaudret, Bruno

    2013-01-01

    A new generation of optimized contrast agents is emerging, based on metallic nanoparticles (NPs) and semiconductor nanocrystals for, respectively, magnetic resonance imaging (MRI) and near-infrared (NIR) fluorescent imaging techniques. Compared with established contrast agents, such as iron oxide NPs or organic dyes, these NPs benefit from several advantages: their magnetic and optical properties can be tuned through size, shape and composition engineering, their efficiency can exceed by several orders of magnitude that of contrast agents clinically used, their surface can be modified to incorporate specific targeting agents and antifolding polymers to increase blood circulation time and tumour recognition, and they can possibly be integrated in complex architecture to yield multi-modal imaging agents. In this review, we will report the materials of choice based on the understanding of the basic physics of NIR and MRI techniques and their corresponding syntheses as NPs. Surface engineering, water transfer and specific targeting will be highlighted prior to their first use for in vivo real-time imaging. Highly efficient NPs that are safer and target specific are likely to enter clinical application in a near future. PMID:24427542

  15. Contrast-enhanced near-infrared laser mammography with a prototype breast scanner: feasibility study with tissue phantoms and preliminary results of imaging experimental tumors.

    PubMed

    Boehm, T; Hochmuth, A; Malich, A; Reichenbach, J R; Fleck, M; Kaiser, W A

    2001-10-01

    Near-infrared (NIR) optical mammography without contrast has a low specificity. The application of optical contrast medium may improve the performance. The concentration-dependent detectability of a new NIR contrast medium was determined with a prototype optical breast scanner. In vivo imaging of experimental tumors was performed. The NIR contrast agent NIR96010 is a newly synthesized, hydrophilic contrast agent for NIR mammography. A concentration-dependent contrast resolution was determined for tissue phantoms consisting of whole milk powder and gelatin. A central part of the phantoms measuring 2 x 2 cm2 without contrast was replaced with phantom material containing 1 micromol/L to 25 nmol/L NIR96010. The composite phantoms were measured with a prototype NIR breast scanner with lasers of lambda1 = 785 nm and lambda2 = 850 nm wavelength. Intensity profiles and standard deviations of the transmission signal in areas with and without contrast were determined by linear fit procedures. Signal-to-noise ratios and spatial resolution as a function of contrast concentration were determined. Near-infrared imaging of five tumor-bearing SCID mice (MX1 breast adenocarcinoma, tumor diameter 5-10 mm) was performed before and after intravenous application of 2 micromol/kg NIR96010. Spectrometry showed an absorption maximum of the contrast agent at 755 nm. No spectral shifts occurred in protein-containing solution. Signal-to-noise ratio in the transmission intensity profiles ranged from 1.1 at 25 nmol/L contrast to 28 at 1 micromol/L. At concentrations <40 nmol/L, no differentiation from the background was possible. The transitional area between the contrast-free edge of the phantom and the central contrast-containing part appeared in the profiles as a steep increase with a width of 4.2 +/- 1.8 mm. The experimental tumors were detectable in nonenhanced images as well as contrast-enhanced images, with better delineation after contrast administration. In postcontrast absorption profiles, a 44.1% +/- 11.3% greater absorption increase was seen in tumor tissue compared with normal tissue. The laser wavelength lambda1 of the prototype laser mammography device was not situated at maximum absorption of the contrast agent NIR96010 but on the descending shoulder of the absorption spectrum. This implies a 20% signal loss for contrast detection. Despite the nonideal measurement conditions, concentrations as low as 40 nmol/L were detectable in vitro. In vivo, all tumors were detectable in color-coded nonenhanced scans as well as in contrast-enhanced scans, with better delineation after contrast administration.

  16. SiC: An Agent Based Architecture for Preventing and Detecting Attacks to Ubiquitous Databases

    NASA Astrophysics Data System (ADS)

    Pinzón, Cristian; de Paz, Yanira; Bajo, Javier; Abraham, Ajith; Corchado, Juan M.

    One of the main attacks to ubiquitous databases is the structure query language (SQL) injection attack, which causes severe damages both in the commercial aspect and in the user’s confidence. This chapter proposes the SiC architecture as a solution to the SQL injection attack problem. This is a hierarchical distributed multiagent architecture, which involves an entirely new approach with respect to existing architectures for the prevention and detection of SQL injections. SiC incorporates a kind of intelligent agent, which integrates a case-based reasoning system. This agent, which is the core of the architecture, allows the application of detection techniques based on anomalies as well as those based on patterns, providing a great degree of autonomy, flexibility, robustness and dynamic scalability. The characteristics of the multiagent system allow an architecture to detect attacks from different types of devices, regardless of the physical location. The architecture has been tested on a medical database, guaranteeing safe access from various devices such as PDAs and notebook computers.

  17. Tuning the relaxation rates of dual-mode T1/T2 nanoparticle contrast agents: a study into the ideal system

    NASA Astrophysics Data System (ADS)

    Keasberry, Natasha A.; Bañobre-López, Manuel; Wood, Christopher; Stasiuk, Graeme. J.; Gallo, Juan; Long, Nicholas. J.

    2015-09-01

    Magnetic resonance imaging (MRI) is an excellent imaging modality. However the low sensitivity of the technique poses a challenge to achieving an accurate image of function at the molecular level. To overcome this, contrast agents are used; typically gadolinium based agents for T1 weighted imaging, or iron oxide based agents for T2 imaging. Traditionally, only one imaging mode is used per diagnosis although several physiological situations are known to interfere with the signal induced by the contrast agents in each individual imaging mode acquisition. Recently, the combination of both T1 and T2 imaging capabilities into a single platform has emerged as a tool to reduce uncertainties in MR image analysis. To date, contradicting reports on the effect on the contrast of the coupling of a T1 and T2 agent have hampered the application of these specialised probes. Herein, we present a systematic experimental study on a range of gadolinium-labelled magnetite nanoparticles envisioned to bring some light into the mechanism of interaction between T1 and T2 components, and advance towards the design of efficient (dual) T1 and T2 MRI probes. Unexpected behaviours observed in some of the constructs will be discussed. In this study, we demonstrate that the relaxivity of such multimodal probes can be rationally tuned to obtain unmatched potentials in MR imaging, exemplified by preparation of the magnetite-based nanoparticle with the highest T2 relaxivity described to date.Magnetic resonance imaging (MRI) is an excellent imaging modality. However the low sensitivity of the technique poses a challenge to achieving an accurate image of function at the molecular level. To overcome this, contrast agents are used; typically gadolinium based agents for T1 weighted imaging, or iron oxide based agents for T2 imaging. Traditionally, only one imaging mode is used per diagnosis although several physiological situations are known to interfere with the signal induced by the contrast agents in each individual imaging mode acquisition. Recently, the combination of both T1 and T2 imaging capabilities into a single platform has emerged as a tool to reduce uncertainties in MR image analysis. To date, contradicting reports on the effect on the contrast of the coupling of a T1 and T2 agent have hampered the application of these specialised probes. Herein, we present a systematic experimental study on a range of gadolinium-labelled magnetite nanoparticles envisioned to bring some light into the mechanism of interaction between T1 and T2 components, and advance towards the design of efficient (dual) T1 and T2 MRI probes. Unexpected behaviours observed in some of the constructs will be discussed. In this study, we demonstrate that the relaxivity of such multimodal probes can be rationally tuned to obtain unmatched potentials in MR imaging, exemplified by preparation of the magnetite-based nanoparticle with the highest T2 relaxivity described to date. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr04400f

  18. Monitoring caustic injuries from emergency department databases using automatic keyword recognition software.

    PubMed

    Vignally, P; Fondi, G; Taggi, F; Pitidis, A

    2011-03-31

    In Italy the European Union Injury Database reports the involvement of chemical products in 0.9% of home and leisure accidents. The Emergency Department registry on domestic accidents in Italy and the Poison Control Centres record that 90% of cases of exposure to toxic substances occur in the home. It is not rare for the effects of chemical agents to be observed in hospitals, with a high potential risk of damage - the rate of this cause of hospital admission is double the domestic injury average. The aim of this study was to monitor the effects of injuries caused by caustic agents in Italy using automatic free-text recognition in Emergency Department medical databases. We created a Stata software program to automatically identify caustic or corrosive injury cases using an agent-specific list of keywords. We focused attention on the procedure's sensitivity and specificity. Ten hospitals in six regions of Italy participated in the study. The program identified 112 cases of injury by caustic or corrosive agents. Checking the cases by quality controls (based on manual reading of ED reports), we assessed 99 cases as true positive, i.e. 88.4% of the patients were automatically recognized by the software as being affected by caustic substances (99% CI: 80.6%- 96.2%), that is to say 0.59% (99% CI: 0.45%-0.76%) of the whole sample of home injuries, a value almost three times as high as that expected (p < 0.0001) from European codified information. False positives were 11.6% of the recognized cases (99% CI: 5.1%- 21.5%). Our automatic procedure for caustic agent identification proved to have excellent product recognition capacity with an acceptable level of excess sensitivity. Contrary to our a priori hypothesis, the automatic recognition system provided a level of identification of agents possessing caustic effects that was significantly much greater than was predictable on the basis of the values from current codifications reported in the European Database.

  19. Iodinated contrast media and their adverse reactions.

    PubMed

    Singh, Jagdish; Daftary, Aditya

    2008-06-01

    Cross-use of technology between nuclear medicine and radiology technologists is expanding. The growth of PET/CT and the increasing use of intravenous contrast agents during these procedures bring the nuclear medicine technologist into direct contact with these agents and their associated complications. A basic understanding of the occurrence, risk factors, clinical features, and management of these procedures is of increasing importance to the nuclear medicine technologist. After reading this article, the technologist will be able to list the factors that increase the risk of contrast reactions; understand ways to minimize the occurrence of contrast reactions; and develop a plan to identify, treat, and manage the reactions effectively.

  20. Spectral fractionation detection of gold nanorod contrast agents using optical coherence tomography

    PubMed Central

    Jia, Yali; Liu, Gangjun; Gordon, Andrew Y.; Gao, Simon S.; Pechauer, Alex D.; Stoddard, Jonathan; McGill, Trevor J.; Jayagopal, Ashwath; Huang, David

    2015-01-01

    We demonstrate the proof of concept of a novel Fourier-domain optical coherence tomography contrast mechanism using gold nanorod contrast agents and a spectral fractionation processing technique. The methodology detects the spectral shift of the backscattered light from the nanorods by comparing the ratio between the short and long wavelength halves of the optical coherence tomography signal intensity. Spectral fractionation further divides the halves into sub-bands to improve spectral contrast and suppress speckle noise. Herein, we show that this technique can detect gold nanorods in intralipid tissue phantoms. Furthermore, cellular labeling by gold nanorods was demonstrated using retinal pigment epithelial cells in vitro. PMID:25836459

  1. Contrast-enhanced ultrasound imaging and in vivo circulatory kinetics with low-boiling-point nanoscale phase-change perfluorocarbon agents.

    PubMed

    Sheeran, Paul S; Rojas, Juan D; Puett, Connor; Hjelmquist, Jordan; Arena, Christopher B; Dayton, Paul A

    2015-03-01

    Many studies have explored phase-change contrast agents (PCCAs) that can be vaporized by an ultrasonic pulse to form microbubbles for ultrasound imaging and therapy. However, few investigations have been published on the utility and characteristics of PCCAs as contrast agents in vivo. In this study, we examine the properties of low-boiling-point nanoscale PCCAs evaluated in vivo and compare data with those for conventional microbubbles with respect to contrast generation and circulation properties. To do this, we develop a custom pulse sequence to vaporize and image PCCAs using the Verasonics research platform and a clinical array transducer. Results indicate that droplets can produce contrast enhancement similar to that of microbubbles (7.29 to 18.24 dB over baseline, depending on formulation) and can be designed to circulate for as much as 3.3 times longer than microbubbles. This study also reports for the first time the ability to capture contrast washout kinetics of the target organ as a measure of vascular perfusion. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  2. Carbon Dioxide Angiography: Scientific Principles and Practice

    PubMed Central

    Cho, Kyung Jae

    2015-01-01

    Carbon dioxide (CO2) is a colorless, odorless gas which occurs naturally in the atmosphere and human body. With the advent of digital subtraction angiography, the gas has been used as a safe and useful alternative contrast agent in both arteriography and venography. Because of its lack of renal toxicity and allergic potential, CO2 is a preferred contrast agent in patients with renal failure or contrast allergy, and particularly in patients who require large volumes of contrast medium for complex endovascular procedures. Understanding of the unique physical properties of CO2 (high solubility, low viscosity, buoyancy, and compressibility) is essential in obtaining a successful CO2 angiogram and in guiding endovascular intervention. Unlike iodinated contrast material, CO2 displaces the blood and produces a negative contrast for digital subtraction imaging. Indications for use of CO2 as a contrast agent include: aortography and runoff, detection of bleeding, renal transplant arteriography, portal vein visualization with wedged hepatic venous injection, venography, arterial and venous interventions, and endovascular aneurysm repair. CO2 should not be used in the thoracic aorta, the coronary artery, and cerebral circulation. Exploitation of CO2 properties, avoidance of air contamination and facile catheterization technique are important to the safe and effective performance of CO2 angiography and CO2-guided endovascular intervention. PMID:26509137

  3. Agent-Based Framework for Discrete Entity Simulations

    DTIC Science & Technology

    2006-11-01

    Postgres database server for environment queries of neighbors and continuum data. As expected for raw database queries (no database optimizations in...form. Eventually the code was ported to GNU C++ on the same single Intel Pentium 4 CPU running RedHat Linux 9.0 and Postgres database server...Again Postgres was used for environmental queries, and the tool remained relatively slow because of the immense number of queries necessary to assess

  4. A modified commercial ultrasound scanner used for in vivo photoacoustic imaging of nude mice injected with non-targeted contrast agents

    NASA Astrophysics Data System (ADS)

    Jankovic, Ladislav; Shahzad, Khalid; Wang, Yao; Burcher, Michael; Scholle, Frank-Detlef; Hauff, Peter; Mofina, Sabine; Skobe, Mihaela

    2008-02-01

    Photoacoustic (PA) experiments were performed using a modified commercial ultrasound scanner equipped with an array transducer and a Nd:YAG pumped OPO laser. The contrast agent SIDAG (Bayer Schering Pharma AG, Germany), used to enhance the optical absorption, demonstrated an expected pharmacokinetic behavior of the dye in the tumor and in the bladder of the nude mice. A typical behavior in the tumor consisted of an initial linear increase in PA signal followed by an exponential decay. PA signal approached the pre-injection level after about one hour following the dye injection, which was consistent with the behavior for such contrast agents when used in other imaging modalities, such as fluorescence imaging. The in-vivo spectral PA data from the mouse bladder, conducted 1.5 hours after the dye injection, clearly demonstrated presence of the dye. The multi-spectral PA data was obtained at 760nm, 784nm and 850nm laser excitations. The PA intensities obtained at these three wavelengths accurately matched the dye absorption spectrum. In addition, in the kidney, a clearance organ for this contrast agent, both in-vivo and ex-vivo results demonstrated a significant increase (~ 40%) in the ratio of PA signal at 760nm (the peak of the dye absorption) relative to the signal at 850nm (<1% absorption), indicating significant amounts of the dye in this organ. Our initial results confirm the desired photoacoustic properties of the contrast agent, indicating its great potential to be used for imaging with a commercial array-based ultrasound scanner.

  5. Tracing gadolinium-based contrast agents from surface water to drinking water by means of speciation analysis.

    PubMed

    Birka, Marvin; Wehe, Christoph A; Hachmöller, Oliver; Sperling, Michael; Karst, Uwe

    2016-04-01

    In recent decades, a significant amount of anthropogenic gadolinium has been released into the environment as a result of the broad application of contrast agents for magnetic resonance imaging (MRI). Since this anthropogenic gadolinium anomaly has also been detected in drinking water, it has become necessary to investigate the possible effect of drinking water purification on these highly polar microcontaminats. Therefore, a novel highly sensitive method for speciation analysis of gadolinium is presented. For that purpose, the hyphenation of hydrophilic interaction liquid chromatography (HILIC) and inductively coupled plasma-mass spectrometry (ICP-MS) was employed. In order to enhance the detection power, sample introduction was carried out by ultrasonic nebulization. In combination with a novel HILIC method using a diol-based stationary phase, it was possible to achieve superior limits of detection for frequently applied gadolinium-based contrast agents below 20pmol/L. With this method, the contrast agents Gd-DTPA, Gd-DOTA and Gd-BT-DO3A were determined in concentrations up to 159pmol/L in samples from several waterworks in a densely populated region of Germany alongside the river Ruhr as well as from a waterworks near a catchment lake. Thereby, the direct impact of anthropogenic gadolinium species being present in the surface water on the amount of anthropogenic gadolinium in drinking water was shown. There was no evidence for the degradation of contrast agents, the release of Gd(3+) or the presence of further Gd species. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Polymeric contrast agents for medical imaging.

    PubMed

    Torchilin, V P

    2000-09-01

    Synthetic polymers and co-polymers are described, to be used as carriers of reporter groups for gamma-, magnetic resonance (MR), and computed tomography (CT) imaging. Those compounds include polychelating and amphiphilic polymers and serve as key components of various contrast agents. Single terminus-activated polychelating polymers were synthesized using poly-L-lysine (PLL) as a main chain and chelating moieties (such as diethylene triamine pentaacetic acid or DTPA) as side groups. These polymers were used for the modification of diagnostic monoclonal antibodies to increase their load with reporter metal atoms. As a result, better images within shorter time intervals were obtained in animal experiments. The application of liposomes and micelles as carriers for diagnostic imaging agents in experimental and clinical medicine is considered. The load of liposomes and micelles with contrast agents for gamma- and MR imaging (MRI) was sharply increased by using polychelating polymers additionally modified on one end with a hydrophobic phospholipid residue to give amphiphilic polymers. Such polymers easily incorporate the liposome membrane or micelle core and provide better loading of liposomes and micelles with reporter metals and, consequently, better and faster imaging of various physiological compartments, such as lymphatic and vascular systems. A block-copolymer of methoxy-poly(ethylene glycol) (MPEG) and iodine-substituted PLL was synthesized to prepare long-circulating contrast agent for CT imaging of the blood pool. In the aqueous solution, this copolymer forms stable and heavily loaded with iodine (up to 30% of iodine by weight) micelles. These micelle were successfully used for CT visualization of the vascular network in experimental animals. General trends in developing contrast polymers are discussed.

  7. Laser ablation of basal cell carcinomas guided by confocal microscopy

    NASA Astrophysics Data System (ADS)

    Sierra, Heidy; Cordova, Miguel; Nehal, Kishwer; Rossi, Anthony; Chen, Chih-Shan Jason; Rajadhyaksha, Milind

    2016-02-01

    Laser ablation offers precise and fast removal of superficial and early nodular types of basal cell carcinomas (BCCs). Nevertheless, the lack of histological confirmation has been a limitation. Reflectance confocal microscopy (RCM) imaging combined with a contrast agent can offer cellular-level histology-like feedback to detect the presence (or absence) of residual BCC directly on the patient. We conducted an ex vivo bench-top study to provide a set of effective ablation parameters (fluence, number of passes) to remove superficial BCCs while also controlling thermal coagulation post-ablation to allow uptake of contrast agent. The results for an Er:YAG laser (2.9 um and pulse duration 250us) show that with 6 passes of 25 J/cm2, thermal coagulation can be effectively controlled, to allow both the uptake of acetic acid (contrast agent) and detection of residual (or absence) BCCs. Confirmation was provided with histological examination. An initial in vivo study on 35 patients shows that the uptake of contrast agent aluminum chloride) and imaging quality is similar to that observed in the ex vivo study. The detection of the presence of residual tumor or complete clearance was confirmed in 10 wounds with (additional) histology and in 25 lesions with follow-up imaging. Our results indicate that resolution is sufficient but further development and use of appropriate contrast agent are necessary to improve sensitivity and specificity. Advances in RCM technology for imaging of lateral and deep margins directly on the patient may provide less invasive, faster and less expensive image-guided approaches for treatment of BCCs.

  8. Ferrimagnetic ferritin cage nanoparticles used as MRI contrast agent

    NASA Astrophysics Data System (ADS)

    Cai, Y.; Cao, C.; Zhang, T.; Xu, H.; Pan, Y.

    2017-12-01

    The nano-sized ferrimagnetic ferritin cage nanoparticles are ideal materials for understanding of superparamagnetism, biomimetic synthesis of ultrafine magnetic particles and their application in biomedicine. Ferrimagnetic M-HFn nanoparticles with size of magnetite cores in a mean size ranges from 2.7 nm to 5.3 nm were synthesized through loading different amount of iron into recombinant human H chain ferritin (HFn) shells. Both the saturation magnetization (Ms) and blocking temperature (Tb) were increased with the size of ferrimagnetic cores. In essence, magnetic resonance imaging (MRI) analysis showed that the synthesized M-HFn nanoparticles (5.3 nm magnetite core) has extremely high transverse relaxivity (r2) values up to 320.9 mM-1S-1, which indicate that M-HFn nanoparticles are promising negative contrast agent in early detection of tumors. In addition, the longitudinal relaxivity (r1) (10.4 mM-1S-1) and r2/r1 ratio ( 2.2) of M-HFn nanoparticles ( 2.7 nm magnetite core in diameter) will make it a considerable potential as a positive contrast agent in MRI. This means the M-HFn nanoparticles can be used as dual functional MR contrast agent. Acute toxicity study of M-HFn in rats showed that a dosage of 20 mg Fe/kg makes no abnormalities by serum biochemical and hematological analysis as well as histopathological examination. Compared with a similar commercial contrast agent, combidex (with a clinical dosage of 2.7 mg Fe/kg), it indicates that M-HFn nanoparticle is of a relative safe ferrimagnetic nanoparticle when used in vivo.

  9. MRI based on iron oxide nanoparticles contrast agents: effect of oxidation state and architecture

    NASA Astrophysics Data System (ADS)

    Javed, Yasir; Akhtar, Kanwal; Anwar, Hafeez; Jamil, Yasir

    2017-11-01

    Iron oxide nanoparticles (IONPs) extensively employed beyond regenerative medicines to imaging disciplines because of their great constituents for magneto-responsive nano-systems. The unique superparamagnetic behavior makes IONPs very suitable for hyperthermia and imaging applications. From the last decade, versatile functionalization with surface capabilities, efficient contrast properties and biocompatibilities make IONPs an essential imaging contrast agent for magnetic resonance imaging (MRI). IONPs have shown signals for both longitudinal relaxation and transverse relaxation; therefore, negative contrast as well as dual contrast can be used for imaging in MRI. In the current review, we have focused on different oxidation state of iron oxides, i.e., magnetite, maghemite and hematite for their T1 and T2 contrast enhancement properties. We have also discussed different factors (synthesis protocols, biocompatibility, toxicity, architecture, etc.) that can affect the contrast properties of the IONPs. [Figure not available: see fulltext.

  10. EXCI-CEST: Exploiting pharmaceutical excipients as MRI-CEST contrast agents for tumor imaging.

    PubMed

    Longo, Dario Livio; Moustaghfir, Fatima Zzahra; Zerbo, Alexandre; Consolino, Lorena; Anemone, Annasofia; Bracesco, Martina; Aime, Silvio

    2017-06-15

    Chemical Exchange Saturation Transfer (CEST) approach is a novel tool within magnetic resonance imaging (MRI) that allows visualization of molecules possessing exchangeable protons with water. Many molecules, employed as excipients for the formulation of finished drug products, are endowed with hydroxyl, amine or amide protons, thus can be exploitable as MRI-CEST contrast agents. Their high safety profiles allow them to be injected at very high doses. Here we investigated the MRI-CEST properties of several excipients (ascorbic acid, sucrose, N-acetyl-d-glucosamine, meglumine and 2-pyrrolidone) and tested them as tumor-detecting agents in two different murine tumor models (breast and melanoma cancers). All the investigated molecules showed remarkable CEST contrast upon i.v. administration in the range 1-3ppm according to the type of mobile proton groups. A marked increase of CEST contrast was observed in tumor regions up to 30min post injection. The combination of marked tumor contrast enhancement and lack of toxicity make these molecules potential candidates for the diagnosis of tumors within the MRI-CEST approach. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Investigation of cyano-bridged coordination nanoparticles Gd3+/[Fe(CN)6]3-/d-mannitol as T1-weighted MRI contrast agents

    NASA Astrophysics Data System (ADS)

    Perrier, M.; Gallud, A.; Ayadi, A.; Kennouche, S.; Porredon, C.; Gary-Bobo, M.; Larionova, J.; Goze-Bac, Ch.; Zanca, M.; Garcia, M.; Basile, I.; Long, J.; de Lapuente, J.; Borras, M.; Guari, Y.

    2015-07-01

    Cyano-bridged Gd3+/[Fe(CN)6]3- coordination polymer nanoparticles of 3-4 nm stabilized with d-mannitol presenting a high r1 relaxivity value of 11.4 mM-1 s-1 were investigated in vivo as contrast agents (CA) for Magnetic Resonance Imaging (MRI). They allow an increase of the MR image contrast and can act as an efficient intravascular T1 CA with a relatively long blood-circulation lifetime (60 min) without specific toxicity.Cyano-bridged Gd3+/[Fe(CN)6]3- coordination polymer nanoparticles of 3-4 nm stabilized with d-mannitol presenting a high r1 relaxivity value of 11.4 mM-1 s-1 were investigated in vivo as contrast agents (CA) for Magnetic Resonance Imaging (MRI). They allow an increase of the MR image contrast and can act as an efficient intravascular T1 CA with a relatively long blood-circulation lifetime (60 min) without specific toxicity. Electronic supplementary information (ESI) available: Experimental details and procedures, toxicological data, physical characterization. See DOI: 10.1039/c5nr01557j

  12. Effect of contrasting agents on survival, performance, and condition of larval hybrid striped bass Morone chrysops x M. saxatilis in tanks

    USDA-ARS?s Scientific Manuscript database

    Contrasting agents, either algae or inert soil, cause turbidity, which is important in the tank culture of larval cannibalistic fish. Optimization of turbidity is critical to successful tank culture of new larval fish, which should include 100 mg/L of sub 5 um particle size in the assessed range. ...

  13. Effect of contrasting agents on survival, performance, and condition of larval hybrid striped bass Morone chrysops x M. saxatilis in tanks.

    USDA-ARS?s Scientific Manuscript database

    Turbidity is important in the tank culture of larval cannibalistic fish. The principal goal of these studies were to characterize the utility and feasibility of select contrasting agents, either algae or inert soil, at improving sunshine bass survival and uniformity of size at time of weaning to an ...

  14. Gd-DTPA-Dopamine-Bisphytanyl Amphiphile: Synthesis, Characterisation and Relaxation Parameters of the Nanoassemblies and Their Potential as MRI Contrast Agents.

    PubMed

    Gupta, Abhishek; Willis, Scott A; Waddington, Lynne J; Stait-Gardner, Tim; de Campo, Liliana; Hwang, Dennis W; Kirby, Nigel; Price, William S; Moghaddam, Minoo J

    2015-09-28

    Here, a new amphiphilic magnetic resonance imaging (MRI) contrast agent, a Gd(III)-chelated diethylenetriaminepentaacetic acid conjugated to two branched alkyl chains via a dopamine spacer, Gd-DTPA-dopamine-bisphytanyl (Gd-DTPA-Dop-Phy), which is readily capable of self-assembling into liposomal nanoassemblies upon dispersion in an aqueous solution, is reported. In vitro relaxivities of the dispersions were found to be much higher than Magnevist, a commercially available contrast agent, at 0.47 T but comparable at 9.40 T. Analysis of variable temperature (17)O NMR transverse relaxation measurements revealed the water exchange of the nanoassemblies to be faster than that previously reported for paramagnetic liposomes. Molecular reorientation dynamics were probed by (1)H NMRD profiles using a classical inner and outer sphere relaxation model and a Lipari-Szabo "model-free" approach. High payloads of Gd(III) ions in the liposomal nanoassemblies made solely from the Gd-DTPA-Dop-Phy amphiphiles, in combination with slow molecular reorientation and fast water exchange makes this novel amphiphile a suitable candidate to be investigated as an advanced MRI contrast agent. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Intraductal papillary mucinous neoplasm penetrating to the stomach, duodenum, and jejunum demonstrated on MR cholangiopancreatography with an oral negative contrast agent.

    PubMed

    Tajima, Naoshi; Utano, Kenichi; Kijima, Shigeyoshi; Kawai, Akira; Fujita, Akifumi; Sakuma, Kazuya; Sugimoto, Hideharu; Fujii, Hirofumi

    2013-07-01

    A 65-year-old man was referred to our hospital due to epigastric pain. Abdominal enhanced computed tomography (CT) demonstrated marked dilatation of the main pancreatic duct (MPD) and communication to the gastric and duodenal lumen was suspected. Esophagogastroduodenoscopy (EGD) showed a villous tumor with white mucous discharge in the posterior wall of the gastric corpus and duodenal bulb. Pathological specimens showed mucin-producing epithelium with nuclear atypia that had developed in a papillary form. Based on these findings, we diagnosed intraductal papillary mucinous neoplasm (IPMN) arising in the MPD with penetration into the gastric and duodenal lumen. Magnetic resonance cholangiopancreatography (MRCP) with an oral negative contrast agent (manganese chloride tetrahydrate) showed a fistulous tract not only to the stomach and duodenum, but also to the jejunum. MRCP demonstrated mucous streaming with remarkably high intensity. In this case, an oral negative contrast agent was useful to distinguish mucous discharge from gastric fluid, facilitating the diagnosis of penetration to the jejunum. This finding was unobtainable by CT or EGD. When IPMN penetrating to other organs is suspected, MRCP with an oral negative contrast agent may provide important information. Copyright © 2012 Wiley Periodicals, Inc.

  16. Quantitative structure-property relationship (correlation analysis) of phosphonic acid-based chelates in design of MRI contrast agent.

    PubMed

    Tiwari, Anjani K; Ojha, Himanshu; Kaul, Ankur; Dutta, Anupama; Srivastava, Pooja; Shukla, Gauri; Srivastava, Rakesh; Mishra, Anil K

    2009-07-01

    Nuclear magnetic resonance imaging is a very useful tool in modern medical diagnostics, especially when gadolinium (III)-based contrast agents are administered to the patient with the aim of increasing the image contrast between normal and diseased tissues. With the use of soft modelling techniques such as quantitative structure-activity relationship/quantitative structure-property relationship after a suitable description of their molecular structure, we have studied a series of phosphonic acid for designing new MRI contrast agent. Quantitative structure-property relationship studies with multiple linear regression analysis were applied to find correlation between different calculated molecular descriptors of the phosphonic acid-based chelating agent and their stability constants. The final quantitative structure-property relationship mathematical models were found as--quantitative structure-property relationship Model for phosphonic acid series (Model 1)--log K(ML) = {5.00243(+/-0.7102)}- MR {0.0263(+/-0.540)}n = 12 l r l = 0.942 s = 0.183 F = 99.165 quantitative structure-property relationship Model for phosphonic acid series (Model 2)--log K(ML) = {5.06280(+/-0.3418)}- MR {0.0252(+/- .198)}n = 12 l r l = 0.956 s = 0.186 F = 99.256.

  17. Ultrasound Molecular Imaging: Moving Towards Clinical Translation

    PubMed Central

    Abou-Elkacem, Lotfi; Bachawal, Sunitha V.; Willmann, Jürgen K.

    2015-01-01

    Ultrasound is a widely available, cost-effective, real-time, non-invasive and safe imaging modality widely used in the clinic for anatomical and functional imaging. With the introduction of novel molecularly-targeted ultrasound contrast agents, another dimension of ultrasound has become a reality: diagnosing and monitoring pathological processes at the molecular level. Most commonly used ultrasound molecular imaging contrast agents are micron sized, gas-containing microbubbles functionalized to recognize and attach to molecules expressed on inflamed or angiogenic vascular endothelial cells. There are several potential clinical applications currently being explored including earlier detection, molecular profiling, and monitoring of cancer, as well as visualization of ischemic memory in transient myocardial ischemia, monitoring of disease activity in inflammatory bowel disease, and assessment of arteriosclerosis. Recently, a first clinical grade ultrasound contrast agent (BR55), targeted at a molecule expressed in neoangiogenesis (vascular endothelial growth factor receptor type 2; VEGFR2) has been introduced and safety and feasibility of VEGFR2-targeted ultrasound imaging is being explored in first inhuman clinical trials in various cancer types. This review describes the design of ultrasound molecular imaging contrast agents, imaging techniques, and potential future clinical applications of ultrasound molecular imaging. PMID:25851932

  18. Design of functionalized gold nanoparticle probes for computed tomography imaging.

    PubMed

    Silvestri, Alessandro; Zambelli, Vanessa; Ferretti, Anna M; Salerno, Domenico; Bellani, Giacomo; Polito, Laura

    2016-09-01

    The development of new molecules able to efficiently act as long-circulating computed tomography (CT) contrast agents is one of the most crucial topics in the biomedical field. In the last years, the chance to manipulate materials at the nano-size level gave new boost to this research, with the specific aim to design innovative nanoprobes. Gold nanoparticles (AuNPs) have showed unique X-rays attenuation properties which, combined with their easy surface functionalization, makes them ideal candidates for the next generation of contrast agents. In this paper, we present a rational and facile approach to synthesize engineered and water-stable AuNPs, achieving concentrated colloidal solution with high Hounsfield Units (HU). An accurate control of reagents ratio allowed us to design AuNPs with different shapes, from symmetrical to anisotropic morphology, in a convenient 'one-pot' fashion. Their activity as efficient and reliable CT contrast agents has been evaluated and compared. Moreover, glucosamine-functionalized gold nanoparticles have been developed ([Au] = 31.20 mg/mL; HU = 2453), in order to obtain a CT contrast agent able to combine spatial resolution with metabolic information. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  19. Ultrasound molecular imaging: Moving toward clinical translation.

    PubMed

    Abou-Elkacem, Lotfi; Bachawal, Sunitha V; Willmann, Jürgen K

    2015-09-01

    Ultrasound is a widely available, cost-effective, real-time, non-invasive and safe imaging modality widely used in the clinic for anatomical and functional imaging. With the introduction of novel molecularly-targeted ultrasound contrast agents, another dimension of ultrasound has become a reality: diagnosing and monitoring pathological processes at the molecular level. Most commonly used ultrasound molecular imaging contrast agents are micron sized, gas-containing microbubbles functionalized to recognize and attach to molecules expressed on inflamed or angiogenic vascular endothelial cells. There are several potential clinical applications currently being explored including earlier detection, molecular profiling, and monitoring of cancer, as well as visualization of ischemic memory in transient myocardial ischemia, monitoring of disease activity in inflammatory bowel disease, and assessment of arteriosclerosis. Recently, a first clinical grade ultrasound contrast agent (BR55), targeted at a molecule expressed in neoangiogenesis (vascular endothelial growth factor receptor type 2; VEGFR2) has been introduced and safety and feasibility of VEGFR2-targeted ultrasound imaging is being explored in first inhuman clinical trials in various cancer types. This review describes the design of ultrasound molecular imaging contrast agents, imaging techniques, and potential future clinical applications of ultrasound molecular imaging. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  20. A Monte Carlo simulation study of an improved K-edge log-subtraction X-ray imaging using a photon counting CdTe detector

    NASA Astrophysics Data System (ADS)

    Lee, Youngjin; Lee, Amy Candy; Kim, Hee-Joung

    2016-09-01

    Recently, significant effort has been spent on the development of photons counting detector (PCD) based on a CdTe for applications in X-ray imaging system. The motivation of developing PCDs is higher image quality. Especially, the K-edge subtraction (KES) imaging technique using a PCD is able to improve image quality and useful for increasing the contrast resolution of a target material by utilizing contrast agent. Based on above-mentioned technique, we presented an idea for an improved K-edge log-subtraction (KELS) imaging technique. The KELS imaging technique based on the PCDs can be realized by using different subtraction energy width of the energy window. In this study, the effects of the KELS imaging technique and subtraction energy width of the energy window was investigated with respect to the contrast, standard deviation, and CNR with a Monte Carlo simulation. We simulated the PCD X-ray imaging system based on a CdTe and polymethylmethacrylate (PMMA) phantom which consists of the various iodine contrast agents. To acquired KELS images, images of the phantom using above and below the iodine contrast agent K-edge absorption energy (33.2 keV) have been acquired at different energy range. According to the results, the contrast and standard deviation were decreased, when subtraction energy width of the energy window is increased. Also, the CNR using a KELS imaging technique is higher than that of the images acquired by using whole energy range. Especially, the maximum differences of CNR between whole energy range and KELS images using a 1, 2, and 3 mm diameter iodine contrast agent were acquired 11.33, 8.73, and 8.29 times, respectively. Additionally, the optimum subtraction energy width of the energy window can be acquired at 5, 4, and 3 keV for the 1, 2, and 3 mm diameter iodine contrast agent, respectively. In conclusion, we successfully established an improved KELS imaging technique and optimized subtraction energy width of the energy window, and based on our results, we recommend using this technique for high image quality.

  1. Conception of the first magnetic resonance imaging contrast agents: a brief history.

    PubMed

    de Haën, C

    2001-08-01

    About 20 years ago, a technological innovation process started that eventually led to the affirmation of magnetic resonance imaging (MRI) contrast agents, which are used today in about 25% of all MRI procedures, as medical diagnostic tools. The process began with exploration of various technical possibilities and the conception in the years 1981 to 1982 of two types of agents (soluble paramagnetic chelates and protection colloid-stabilized colloidal particle solutions of magnetite) that eventually found embodiments in commercially available products. The pioneering products that eventually reached the market were gadopentetate dimeglumine (Magnevist, Schering AG) and the ferumoxides (Endorem, Guerbet SA; or Ferridex , Berlex Laboratories Inc.). The history of the conception phase of the technology is reconstructed here, focusing on the social dynamics rather than on technological aspects. In the period 1981 to 1982, a number of independent inventors from industry and academia conceived of water-soluble paramagnetic chelates and protection colloid-stabilized colloidal solutions of small particles of magnetite, both of acceptable tolerability, as contrast agents for MRI. Priorities on patents conditioned the further course of events. The analyzed history helps in understanding the typical roles of different institutions in technological innovation. The foundation of MRI contrast agent technology in basic science clearly was laid in academia. During the conception of practical products, industry assumed a dominant role. Beginning with the radiological evaluation of candidate products, the collaboration between industry and academia became essential.

  2. Advanced Contrast Agents for Multimodal Biomedical Imaging Based on Nanotechnology.

    PubMed

    Calle, Daniel; Ballesteros, Paloma; Cerdán, Sebastián

    2018-01-01

    Clinical imaging modalities have reached a prominent role in medical diagnosis and patient management in the last decades. Different image methodologies as Positron Emission Tomography, Single Photon Emission Tomography, X-Rays, or Magnetic Resonance Imaging are in continuous evolution to satisfy the increasing demands of current medical diagnosis. Progress in these methodologies has been favored by the parallel development of increasingly more powerful contrast agents. These are molecules that enhance the intrinsic contrast of the images in the tissues where they accumulate, revealing noninvasively the presence of characteristic molecular targets or differential physiopathological microenvironments. The contrast agent field is currently moving to improve the performance of these molecules by incorporating the advantages that modern nanotechnology offers. These include, mainly, the possibilities to combine imaging and therapeutic capabilities over the same theranostic platform or improve the targeting efficiency in vivo by molecular engineering of the nanostructures. In this review, we provide an introduction to multimodal imaging methods in biomedicine, the sub-nanometric imaging agents previously used and the development of advanced multimodal and theranostic imaging agents based in nanotechnology. We conclude providing some illustrative examples from our own laboratories, including recent progress in theranostic formulations of magnetoliposomes containing ω-3 poly-unsaturated fatty acids to treat inflammatory diseases, or the use of stealth liposomes engineered with a pH-sensitive nanovalve to release their cargo specifically in the acidic extracellular pH microenvironment of tumors.

  3. Hydroxypyridonate and hydroxypyrimidinone chelating agents

    DOEpatents

    Raymond, Kenneth N.; Doble, Daniel M.; Sunderland, Christopher J.; Thompson, Marlon

    2005-01-25

    The present invention provides hydroxypyridinone and hydroxypyrimidone chelating agents. Also provides are Gd(III) complexes of these agents, which are useful as contrast enhancing agents for magnetic resonance imaging. The invention also provides methods of preparing the compounds of the invention, as well as methods of using the compounds in magnetic resonance imaging applications.

  4. Brain magnetic resonance imaging with contrast dependent on blood oxygenation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ogawa, S.; Lee, T.M.; Kay, A.R.

    1990-12-01

    Paramagnetic deoxyhemoglobin in venous blood is a naturally occurring contrast agent for magnetic resonance imaging (MRI). By accentuating the effects of this agent through the use of gradient-echo techniques in high yields, the authors demonstrate in vivo images of brain microvasculature with image contrast reflecting the blood oxygen level. This blood oxygenation level-dependent (BOLD) contrast follows blood oxygen changes induced by anesthetics, by insulin-induced hypoglycemia, and by inhaled gas mixtures that alter metabolic demand or blood flow. The results suggest that BOLD contrast can be used to provide in vivo real-time maps of blood oxygenation in the brain under normalmore » physiological conditions. BOLD contrast adds an additional feature to magnetic resonance imaging and complement other techniques that are attempting to provide position emission tomography-like measurements related to regional neural activity.« less

  5. Brain Magnetic Resonance Imaging with Contrast Dependent on Blood Oxygenation

    NASA Astrophysics Data System (ADS)

    Ogawa, S.; Lee, T. M.; Kay, A. R.; Tank, D. W.

    1990-12-01

    Paramagnetic deoxyhemoglobin in venous blood is a naturally occurring contrast agent for magnetic resonance imaging (MRI). By accentuating the effects of this agent through the use of gradient-echo techniques in high fields, we demonstrate in vivo images of brain microvasculature with image contrast reflecting the blood oxygen level. This blood oxygenation level-dependent (BOLD) contrast follows blood oxygen changes induced by anesthetics, by insulin-induced hypoglycemia, and by inhaled gas mixtures that alter metabolic demand or blood flow. The results suggest that BOLD contrast can be used to provide in vivo real-time maps of blood oxygenation in the brain under normal physiological conditions. BOLD contrast adds an additional feature to magnetic resonance imaging and complements other techniques that are attempting to provide positron emission tomography-like measurements related to regional neural activity.

  6. The Wannabee Culture: Why No-One Does What They Used To.

    ERIC Educational Resources Information Center

    Dixon, Anne

    1998-01-01

    Electronic publishing has been an agent for change in not just how one publishes but in what one publishes. Describes HyperCite, a joint project with the Institution of Electrical Engineers (IEE) to create INSPEC database. Highlights include the database; the research phase (cross database searching and new interface); and what and how much was…

  7. Gd-doped BNNTs as T2-weighted MRI contrast agents

    NASA Astrophysics Data System (ADS)

    Ciofani, Gianni; Boni, Adriano; Calucci, Lucia; Forte, Claudia; Gozzi, Alessandro; Mazzolai, Barbara; Mattoli, Virgilio

    2013-08-01

    This work describes, for the first time, doping of boron nitride nanotubes (BNNTs) with gadolinium (Gd@BNNTs), a stable functionalization that permits non-invasive BNNT tracking via magnetic resonance imaging (MRI). We report the structure, Gd loading, and relaxometric properties in water suspension at 7 T of Gd@BNNTs, and show the behaviour of these nanostructures as promising T2-weighted contrast agents. Finally, we demonstrate their complete biocompatibility in vitro on human neuroblastoma cells, together with their ability to effectively label and affect contrast in MRI images at 7 T.

  8. Hafnium-Based Contrast Agents for X-ray Computed Tomography.

    PubMed

    Berger, Markus; Bauser, Marcus; Frenzel, Thomas; Hilger, Christoph Stephan; Jost, Gregor; Lauria, Silvia; Morgenstern, Bernd; Neis, Christian; Pietsch, Hubertus; Sülzle, Detlev; Hegetschweiler, Kaspar

    2017-05-15

    Heavy-metal-based contrast agents (CAs) offer enhanced X-ray absorption for X-ray computed tomography (CT) compared to the currently used iodinated CAs. We report the discovery of new lanthanide and hafnium azainositol complexes and their optimization with respect to high water solubility and stability. Our efforts culminated in the synthesis of BAY-576, an uncharged hafnium complex with 3:2 stoichiometry and broken complex symmetry. The superior properties of this asymmetrically substituted hafnium CA were demonstrated by a CT angiography study in rabbits that revealed excellent signal contrast enhancement.

  9. A comparison of iopromide and iopamidol, two acidoCEST MRI contrast media that measure tumor extracellular pH.

    PubMed

    Moon, Brianna F; Jones, Kyle M; Chen, Liu Qi; Liu, Peilu; Randtke, Edward A; Howison, Christine M; Pagel, Mark D

    2015-01-01

    Acidosis within tumor and kidney tissues has previously been quantitatively measured using a molecular imaging technique known as acidoCEST MRI. The previous studies used iopromide and iopamidol, two iodinated contrast agents that are approved for clinical CT diagnoses and have been repurposed for acidoCEST MRI studies. We aimed to compare the performance of the two agents for measuring pH by optimizing image acquisition conditions, correlating pH with a ratio of CEST effects from an agent, and evaluating the effects of concentration, endogenous T1 relaxation time and temperature on the pH-CEST ratio correlation for each agent. These results showed that the two agents had similar performance characteristics, although iopromide produced a pH measurement with a higher dynamic range while iopamidol produced a more precise pH measurement. We then compared the performance of the two agents to measure in vivo extracellular pH (pHe) within xenograft tumor models of Raji lymphoma and MCF-7 breast cancer. Our results showed that the pHe values measured with each agent were not significantly different. Also, iopromide consistently measured a greater region of the tumor relative to iopamidol in both tumor models. Therefore, an iodinated contrast agent for acidoCEST MRI should be selected based on the measurement properties needed for a specific biomedical study and the pharmacokinetic properties of a specific tumor model. Copyright © 2015 John Wiley & Sons, Ltd.

  10. Biocompatible Polyhydroxyethylaspartamide-based Micelles with Gadolinium for MRI Contrast Agents

    NASA Astrophysics Data System (ADS)

    Jeong, Sang Young; Kim, Hyo Jeong; Kwak, Byung-Kook; Lee, Ha-Young; Seong, Hasoo; Shin, Byung Cheol; Yuk, Soon Hong; Hwang, Sung-Joo; Cho, Sun Hang

    2010-12-01

    Biocompatible poly-[ N-(2-hydroxyethyl)- d, l-aspartamide]-methoxypoly(ethyleneglycol)-hexadecylamine (PHEA-mPEG-C16) conjugated with 1,4,7,10-tetraazacyclododecan-1,4,7,10-tetraacetic acid-gadolinium (DOTA-Gd) via ethylenediamine (ED) was synthesized as a magnetic resonance imaging (MRI) contrast agent. Amphiphilic PHEA-mPEG-C16-ED-DOTA-Gd forms micelle in aqueous solution. All the synthesized materials were characterized by proton nuclear magnetic resonance (1H NMR). Micelle size and shape were examined by dynamic light scattering (DLS) and atomic force microscopy (AFM). Micelles with PHEA-mPEG-C16-ED-DOTA-Gd showed higher relaxivities than the commercially available gadolinium contrast agent. Moreover, the signal intensity of a rabbit liver was effectively increased after intravenous injection of PHEA-mPEG-C16-ED-DOTA-Gd.

  11. Graphene oxide-gadolinium (III) oxide nanoparticle composite: a novel MR contrast agent with high longitudinal and transverse relaxivity

    NASA Astrophysics Data System (ADS)

    Venkatesha, N.; Poojar, Pavan; Geethanath, Sairam; Srivastava, Chandan

    2014-12-01

    Production of bio-compatible contrast agent materials to enhance the sensitivity of the magnetic resonance imaging (MRI) technique is a highly active area in MRI related research. This work illustrates the potential of a new material: graphene oxide-gadolinium (III) oxide nanoparticle (GO-Gd2O3) composite in yielding both transverse (16.3 mM-1 s-1) and longitudinal relaxivity (40 mM-1 s-1) values which are significantly higher than the proton relaxivity values achieved using the gadolinium based contrast agents currently used in MRI. Such high proton relaxivity values can facilitate low dosage of GO-Gd2O3 composite for obtaining both T1 and T2 weighted high signal-to-noise ratio images in MRI.

  12. A Phantom Study of Terahertz Spectroscopy and Imaging of Micro- and Nano-diamonds and Nano-onions as Contrast Agents for Breast Cancer.

    PubMed

    Bowman, Tyler; Walter, Alec; Shenderova, Olga; Nunn, Nicholas; McGuire, Gary; El-Shenawee, Magda

    2017-10-01

    THz imaging is effective in distinguishing between cancerous, healthy, and fatty tissues in breast tumors, but a challenge remains in the contrast between cancerous and fibroglandular (healthy) tissues. This work investigates carbon-based nanoparticles as potential contrast agents for terahertz imaging of breast cancer. Microdiamonds, nanodiamonds, and nanometer-scale onion-like carbon are characterized with terahertz transmission spectroscopy in low-absorption backgrounds of polydimethylsiloxane or polyethylene. The refractive index and absorption coefficients are calculated based on the measured electric fields. Nanodiamonds show little effect on the terahertz signal, microdiamonds express resonance-like, size-dependent absorption peaks, and onion-like carbon provides a uniform increase in the optical properties even at low concentration. Due to its strong interaction with terahertz frequencies and ability to be activated for selective binding to cancer cells, onion-like carbon is implemented into engineered three-dimensional breast tumor models composed of phantom tissue mimicking infiltrating ductal carcinoma surrounded by a phantom mimicking healthy fibroglandular tissue. This model is imaged using the terahertz reflection mode to examine the effectiveness of contrast agents for differentiation between the two tissue types. In both spectroscopy and imaging, a 10% concentration of onion-like carbon shows the strongest impact on the terahertz signal and holds promise as a terahertz contrast agent.

  13. Contrast-enhanced radiotherapy: feasibility and characteristics of the physical absorbed dose distribution for deep-seated tumors

    NASA Astrophysics Data System (ADS)

    Garnica-Garza, H. M.

    2009-09-01

    Radiotherapy using kilovoltage x-rays in conjunction with contrast agents incorporated into the tumor, gold nanoparticles in particular, could represent a potential alternative to current techniques based on high-energy linear accelerators. In this paper, using the voxelized Zubal phantom in conjunction with the Monte Carlo code PENELOPE to model a prostate cancer treatment, it is shown that in combination with a 360° arc delivery technique, tumoricidal doses of radiation can be delivered to deep-seated tumors while still providing acceptable doses to the skin and other organs at risk for gold concentrations in the tumor within the range of 7-10 mg-Au per gram of tissue. Under these conditions and using a x-ray beam with 90% of the fluence within the range of 80-200 keV, a 72 Gy physical absorbed dose to the prostate can be delivered, while keeping the rectal wall, bladder, skin and femoral heads below 65 Gy, 55 Gy, 40 Gy and 30 Gy, respectively. However, it is also shown that non-uniformities in the contrast agent concentration lead to a severe degradation of the dose distribution and that, therefore, techniques to locally quantify the presence of the contrast agent would be necessary in order to determine the incident x-ray fluence that best reproduces the dosimetry obtained under conditions of uniform contrast agent distribution.

  14. Micro-CT Based Experimental Liver Imaging Using a Nanoparticulate Contrast Agent: A Longitudinal Study in Mice

    PubMed Central

    Boll, Hanne; Nittka, Stefanie; Doyon, Fabian; Neumaier, Michael; Marx, Alexander; Kramer, Martin; Groden, Christoph; Brockmann, Marc A.

    2011-01-01

    Background Micro-CT imaging of liver disease in mice relies on high soft tissue contrast to detect small lesions like liver metastases. Purpose of this study was to characterize the localization and time course of contrast enhancement of a nanoparticular alkaline earth metal-based contrast agent (VISCOVER ExiTron nano) developed for small animal liver CT imaging. Methodology ExiTron nano 6000 and ExiTron nano 12000, formulated for liver/spleen imaging and angiography, respectively, were intravenously injected in C57BL/6J-mice. The distribution and time course of contrast enhancement were analysed by repeated micro-CT up to 6 months. Finally, mice developing liver metastases after intrasplenic injection of colon carcinoma cells underwent longitudinal micro-CT imaging after a single injection of ExiTron nano. Principal Findings After a single injection of ExiTron nano the contrast of liver and spleen peaked after 4–8 hours, lasted up to several months and was tolerated well by all mice. In addition, strong contrast enhancement of abdominal and mediastinal lymph nodes and the adrenal glands was observed. Within the first two hours after injection, particularly ExiTron nano 12000 provided pronounced contrast for imaging of vascular structures. ExiTron nano facilitated detection of liver metastases and provided sufficient contrast for longitudinal observation of tumor development over weeks. Conclusions The nanoparticulate contrast agents ExiTron nano 6000 and 12000 provide strong contrast of the liver, spleen, lymph nodes and adrenal glands up to weeks, hereby allowing longitudinal monitoring of pathological processes of these organs in small animals, with ExiTron nano 12000 being particularly optimized for angiography due to its very high initial vessel contrast. PMID:21984939

  15. Contrast media extravasations in patients undergoing computerized tomography scanning: a systematic review and meta-analysis of risk factors and interventions

    PubMed Central

    Ding, Sandrine; Meystre, Nicole Richli; Campeanu, Cosmin; Gullo, Giuseppe

    2018-01-01

    ABSTRACT Objective: To identify risk factors and interventions preventing or reducing contrast medium extravasation. Introduction: Computed tomography (CT) is a radiological examination essential for the diagnosis and monitoring of many diseases. It is often performed with the intravenous (IV) injection of contrast agents. Use of these products can result in a significant complication, extravasation, which is the accidental leakage of IV material into the surrounding tissue. Patients may feel a sharp pain and skin ulceration or necrosis may develop. Inclusion criteria: This review considered studies that included patients (adults and children) undergoing a CT with IV administration of contrast media. The risk factors considered were patient demographics, comorbidities and medication history. This review also investigated any strategies related to: contrast agent, injection per se, material used for injection, apparatus used, healthcare professionals involved, and patient risk assessment performed by the radiology personnel. The comparators were other interventions or usual care. This review investigated randomized controlled trials and non-randomized controlled trials. When neither of these were available, other study designs, such as prospective and retrospective cohort studies, case-control studies and case series, were considered for inclusion. Primary outcomes considered were: extravasation frequency, volume, severity and complications. Methods: The databases PubMed, CINAHL, Embase, the Cochrane Register of Controlled Trials, Web of Science PsycINFO, ProQuest Dissertations and Theses A&I, TRIP Database and ClinicalTrials.gov were searched to find both published and unpublished studies from 1980 to September 2016. Papers were assessed by two independent reviewers for methodological validity using the Joanna Briggs Institute System for the Unified Management, Assessment and Review of Information (JBI SUMARI). Data were extracted using the standardized data extraction tool from JBI SUMARI. In one case, quantitative data from two cohort studies were pooled in a statistical meta-analysis. However, generally, statistical pooling was not possible due to heterogeneity of the interventions, populations of interest or outcomes. Accordingly, the findings have been presented in narrative form. Results: Fifteen articles were selected from a total of 2151 unique studies identified. Two were randomized controlled trials and 13 were quasi-experimental and observational studies. The quality of these studies was judged to be low to moderate. Some patient characteristics, such as female sex and inpatient status, appeared to be risk factors for extravasation. Additionally, injection rate, venous access site and catheter dwelling time could affect the volume extravasated. Preliminary studies seemed to indicate the potential of extravasation detection accessories to identify extravasation and reduce the volume extravasated. The other interventions either did not result in significant reduction in the frequency/volume of extravasation, or the results were mixed across the studies. Conclusions: The majority of the studies included in this review evaluated the outcomes of extravasation frequency and volume. Given the quality of the primary studies, this systematic review identified only potential risk factors and interventions. It further highlighted the research gap in this area and the importance of conducting trials with solid methodological designs. PMID:29324560

  16. Development of nanostars as a biocompatible tumor contrast agent: toward in vivo SERS imaging.

    PubMed

    D'Hollander, Antoine; Mathieu, Evelien; Jans, Hilde; Vande Velde, Greetje; Stakenborg, Tim; Van Dorpe, Pol; Himmelreich, Uwe; Lagae, Liesbet

    2016-01-01

    The need for sensitive imaging techniques to detect tumor cells is an important issue in cancer diagnosis and therapy. Surface-enhanced Raman scattering (SERS), realized by chemisorption of compounds suitable for Raman spectroscopy onto gold nanoparticles, is a new method for detecting a tumor. As a proof of concept, we studied the use of biocompatible gold nanostars as sensitive SERS contrast agents targeting an ovarian cancer cell line (SKOV3). Due to a high intracellular uptake of gold nanostars after 6 hours of exposure, they could be detected and located with SERS. Using these nanostars for passive targeting after systemic injection in a xenograft mouse model, a detectable signal was measured in the tumor and liver in vivo. These signals were confirmed by ex vivo SERS measurements and darkfield microscopy. In this study, we established SERS nanostars as a highly sensitive contrast agent for tumor detection, which opens the potential for their use as a theranostic agent against cancer.

  17. Optically enhanced blood-brain-barrier crossing of plasmonic-active nanoparticles in preclinical brain tumor animal models

    NASA Astrophysics Data System (ADS)

    Yuan, Hsiangkuo; Wilson, Christy M.; Li, Shuqin; Fales, Andrew M.; Liu, Yang; Grant, Gerald; Vo-Dinh, Tuan

    2014-02-01

    Nanotechnology provides tremendous biomedical opportunities for cancer diagnosis, imaging, and therapy. In contrast to conventional chemotherapeutic agents where their actual target delivery cannot be easily imaged, integrating imaging and therapeutic properties into one platform facilitates the understanding of pharmacokinetic profiles, and enables monitoring of the therapeutic process in each individual. Such a concept dubbed "theranostics" potentiates translational research and improves precision medicine. One particular challenging application of theranostics involves imaging and controlled delivery of nanoplatforms across blood-brain-barrier (BBB) into brain tissues. Typically, the BBB hinders paracellular flux of drug molecules into brain parenchyma. BBB disrupting agents (e.g. mannitol, focused ultrasound), however, suffer from poor spatial confinement. It has been a challenge to design a nanoplatform not only acts as a contrast agent but also improves the BBB permeation. In this study, we demonstrated the feasibility of plasmonic gold nanoparticles as both high-resolution optical contrast agent and focalized tumor BBB permeation-inducing agent. We specifically examined the microscopic distribution of nanoparticles in tumor brain animal models. We observed that most nanoparticles accumulated at the tumor periphery or perivascular spaces. Nanoparticles were present in both endothelial cells and interstitial matrices. This study also demonstrated a novel photothermal-induced BBB permeation. Fine-tuning the irradiating energy induced gentle disruption of the vascular integrity, causing short-term extravasation of nanomaterials but without hemorrhage. We conclude that our gold nanoparticles are a powerful biocompatible contrast agent capable of inducing focal BBB permeation, and therefore envision a strong potential of plasmonic gold nanoparticle in future brain tumor imaging and therapy.

  18. Magnetomotive Molecular Nanoprobes

    PubMed Central

    John, Renu; Boppart, Stephen A.

    2012-01-01

    Tremendous developments in the field of biomedical imaging in the past two decades have resulted in the transformation of anatomical imaging to molecular-specific imaging. The main approaches towards imaging at a molecular level are the development of high resolution imaging modalities with high penetration depths and increased sensitivity, and the development of molecular probes with high specificity. The development of novel molecular contrast agents and their success in molecular optical imaging modalities have lead to the emergence of molecular optical imaging as a more versatile and capable technique for providing morphological, spatial, and functional information at the molecular level with high sensitivity and precision, compared to other imaging modalities. In this review, we discuss a new class of dynamic contrast agents called magnetomotive molecular nanoprobes for molecular-specific imaging. Magnetomotive agents are superparamagnetic nanoparticles, typically iron-oxide, that are physically displaced by the application of a small modulating external magnetic field. Dynamic phase-sensitive position measurements are performed using any high resolution imaging modality, including optical coherence tomography (OCT), ultrasonography, or magnetic resonance imaging (MRI). The dynamics of the magnetomotive agents can be used to extract the biomechanical tissue properties in which the nanoparticles are bound, and the agents can be used to deliver therapy via magnetomotive displacements to modulate or disrupt cell function, or hyperthermia to kill cells. These agents can be targeted via conjugation to antibodies, and in vivo targeted imaging has been shown in a carcinogen-induced rat mammary tumor model. The iron-oxide nanoparticles also exhibit negative T2 contrast in MRI, and modulations can produce ultrasound imaging contrast for multimodal imaging applications. PMID:21517766

  19. Comparison of transcutaneous contrast-enhanced ultrasound-guided injected hemostatic agents with traditional surgery treatment for liver, spleen and kidney trauma: a retrospective study.

    PubMed

    Wang, Dong; Lv, Faqin; Luo, Yukun; An, Lichun; Li, Junlai; Xie, Xia; Tian, Jiangke; Zhao, Weiyan; Tang, Jie

    2012-10-01

    There is lack of studies on the effectiveness of transcutaneous contrast-enhanced ultrasound-guided injections of hemostatic agents for liver. spleen and kidney trauma. We compared treatment by hemostatic agents to surgical treatment in a retrospective interventional human study. The study enrolled a total of 135 subjects from emergency unit of the Chinese People's Liberation Army General Hospital in Beijing. Within the cohort, 62 patients received contrast enhanced ultrasound-guided injection of hemostatic agents and the rest received surgical treatments. The injury severity score was lower in the hemostatic agent treatment group than surgical treatment group (p<0.05), but Glasgow coma scale scores did not reach statistical significance. The patients in the surgical treatment group had significantly higher hospital fees than those in the hemostatic treatment group (p<0.05), although the length of hospitalization did not significantly differ between two groups. Safety outcome variables pre- and post-treatment remained within normal limits in both groups. Hemostatic agents were more cost-effective than surgery to treat patients with liver, spleen and kidney trauma. However, given the limited sample size, subsequent studies drawing upon larger populations from multiple medical centers are necessary for follow-up.

  20. Copper sulfide nanodisk as photoacoustic contrast agent for ovarian tumor detection

    NASA Astrophysics Data System (ADS)

    Wang, Junxin; Hsu, Su-Wen; Tao, Andrea R.; Jokerst, Jesse V.

    2017-03-01

    Ultrasound is broadly used in the clinics yet is limited in early cancer detection because of its poor contrast between healthy and diseased tissues. Photoacoustic imaging can improve this limitation and has been extensively studied in pre-clinical models. Contrast agents can help improve the accuracy of diagnosis. We recently reported a novel copper sulfide (CuS) nanodisk with strong directionally-localized surface plasmon resonance in the near infrared region. This plasmonic resonance of nanodisks is tunable by changing the size and aspect ratio of CuS nanodisk. Here, we demonstrate this CuS nanodisk is a strong photoacoustic contrast agent. We prepared CuS nanodisks via a solvent-based synthesis followed by surface modification of poly(ethylene glycol) methyl ether thiol for in vivo applications. These CuS nanodisks can be detected at a concentration as low as 26 pM at 920 nm. Their nanosize and strong photoacoustic response make this novel CuS nanodisk a strong candidate for photoacoustic cancer imaging.

  1. Use of Fc-Engineered Antibodies as Clearing Agents to Increase Contrast During PET

    PubMed Central

    Swiercz, Rafal; Chiguru, Srinivas; Tahmasbi, Amir; Ramezani, Saleh M.; Hao, Guiyang; Challa, Dilip K.; Lewis, Matthew A.; Kulkarni, Padmakar V.; Sun, Xiankai; Ober, Raimund J.; Mason, Ralph P.; Ward, E. Sally

    2015-01-01

    Despite promise for the use of antibodies as molecular imaging agents in PET, their long in vivo half-lives result in poor contrast and radiation damage to normal tissue. This study describes an approach to overcome these limitations. Methods Mice bearing human epidermal growth factor receptor type 2 (HER2)–overexpressing tumors were injected with radiolabeled (124I, 125I) HER2-specific antibody (pertuzumab). Pertuzumab injection was followed 8 h later by the delivery of an engineered, antibody-based inhibitor of the receptor, FcRn. Biodistribution analyses and PET were performed at 24 and 48 h after pertuzumab injection. Results The delivery of the engineered, antibody-based FcRn inhibitor (or Abdeg, for antibody that enhances IgG degradation) results in improved tumor-to-blood ratios, reduced systemic exposure to radiolabel, and increased contrast during PET. Conclusion Abdegs have considerable potential as agents to stringently regulate antibody dynamics in vivo, resulting in increased contrast during molecular imaging with PET. PMID:24868106

  2. Exchange-Mediated Contrast Agents for Spin-Lock Imaging

    PubMed Central

    Cobb, Jared G.; Xie, Jingping; Li, Ke; Gochberg, Daniel F.; Gore, John C.

    2011-01-01

    Measurements of relaxation rates in the rotating frame with spin-locking (SL) techniques are sensitive to substances with exchanging protons with appropriate chemical shifts. We develop a novel approach to exchange rate selective imaging based on measured T1ρ dispersion with applied locking field strength, and demonstrate the method on samples containing the X-ray contrast agent Iohexol (IO) with and without cross-linked bovine serum albumin (BSA). T1ρ dispersion of water in the phantoms was measured with a Varian 9.4T magnet by an on-resonance SL pulse with fast spin-echo readout, and the results used to estimate exchange rates. The IO phantom alone gave a fitted exchange rate of ~1 kHz, BSA alone was ~11 kHz, and in combination gave rates in between. By using these estimated rates, we demonstrate how a novel SL imaging method may be used to enhance contrast due to the presence of a contrast agent whose protons have specific exchange rates. PMID:21954094

  3. A pH-activatable nanoparticle with signal-amplification capabilities for non-invasive imaging of tumour malignancy.

    PubMed

    Mi, Peng; Kokuryo, Daisuke; Cabral, Horacio; Wu, Hailiang; Terada, Yasuko; Saga, Tsuneo; Aoki, Ichio; Nishiyama, Nobuhiro; Kataoka, Kazunori

    2016-08-01

    Engineered nanoparticles that respond to pathophysiological parameters, such as pH or redox potential, have been developed as contrast agents for the magnetic resonance imaging (MRI) of tumours. However, beyond anatomic assessment, contrast agents that can sense these pathological parameters and rapidly amplify their magnetic resonance signals are desirable because they could potentially be used to monitor the biological processes of tumours and improve cancer diagnosis. Here, we report an MRI contrast agent that rapidly amplifies magnetic resonance signals in response to pH. We confined Mn(2+) within pH-sensitive calcium phosphate (CaP) nanoparticles comprising a poly(ethylene glycol) shell. At a low pH, such as in solid tumours, the CaP disintegrates and releases Mn(2+) ions. Binding to proteins increases the relaxivity of Mn(2+) and enhances the contrast. We show that these nanoparticles could rapidly and selectively brighten solid tumours, identify hypoxic regions within the tumour mass and detect invisible millimetre-sized metastatic tumours in the liver.

  4. Novel DiR and SPIO nanoparticles embedded PEG-PLGA nanobubbles as a multimodalimaging contrast agent.

    PubMed

    Luo, Binhua; Zhang, Huajie; Liu, Xuhan; Rao, Rong; Wu, Yun; Liu, Wei

    2015-01-01

    Fluorescence dye DiR and superparamagnetic iron oxide nanoparticles (SPIONs) embedded in PEG-PLGA nanobubbles (DiR-SPIO-NBs) were produced using double emulsion method on a membrane of Shirasu porous glass (SPG). The nanobubbles encapsulated with DiR and SPIONs had a liquid core (perfluoropentane) and a PEG-PLGA shell. DiR-SPIO-NBs showed biocompatibility based on MTT cytotoxicity and hemolysis studies. The PFP encapsulated in the nanobubbles experienced phase transition under ultrasonic irradation. Nanobubbles dispersed well in saline over 3 months, and the relaxivity was 127.9 mM(-1)s(-1), suggesting that it could be used as a contrast agent in MRI. The MR and fluorescence images in vivo demonstrated that the signal intensity in the spleen and liver was significantly enhanced with the treatment of nanobubbles. In addition, results of ultrasound images suggested that the nanobubbles had persistent contrast ability. In conclusion, nanobubbles could be utilized as an US/MRI/fluorescence contrast agent.

  5. New generation ICG-based contrast agents for ultrasound-switchable fluorescence imaging

    PubMed Central

    Yu, Shuai; Cheng, Bingbing; Yao, Tingfeng; Xu, Cancan; Nguyen, Kytai T.; Hong, Yi; Yuan, Baohong

    2016-01-01

    Recently, we developed a new technology, ultrasound-switchable fluorescence (USF), for high-resolution imaging in centimeter-deep tissues via fluorescence contrast. The success of USF imaging highly relies on excellent contrast agents. ICG-encapsulated poly(N-isopropylacrylamide) nanoparticles (ICG-NPs) are one of the families of the most successful near-infrared (NIR) USF contrast agents. However, the first-generation ICG-NPs have a short shelf life (<1 month). This work significantly increases the shelf life of the new-generation ICG-NPs (>6 months). In addition, we have conjugated hydroxyl or carboxyl function groups on the ICG-NPs for future molecular targeting. Finally, we have demonstrated the effect of temperature-switching threshold (Tth) and the background temperature (TBG) on the quality of USF images. We estimated that the Tth of the ICG-NPs should be controlled at ~38–40 °C (slightly above the body temperature of 37 °C) for future in vivo USF imaging. Addressing these challenges further reduces the application barriers of USF imaging. PMID:27775014

  6. A pH-activatable nanoparticle with signal-amplification capabilities for non-invasive imaging of tumour malignancy

    NASA Astrophysics Data System (ADS)

    Mi, Peng; Kokuryo, Daisuke; Cabral, Horacio; Wu, Hailiang; Terada, Yasuko; Saga, Tsuneo; Aoki, Ichio; Nishiyama, Nobuhiro; Kataoka, Kazunori

    2016-08-01

    Engineered nanoparticles that respond to pathophysiological parameters, such as pH or redox potential, have been developed as contrast agents for the magnetic resonance imaging (MRI) of tumours. However, beyond anatomic assessment, contrast agents that can sense these pathological parameters and rapidly amplify their magnetic resonance signals are desirable because they could potentially be used to monitor the biological processes of tumours and improve cancer diagnosis. Here, we report an MRI contrast agent that rapidly amplifies magnetic resonance signals in response to pH. We confined Mn2+ within pH-sensitive calcium phosphate (CaP) nanoparticles comprising a poly(ethylene glycol) shell. At a low pH, such as in solid tumours, the CaP disintegrates and releases Mn2+ ions. Binding to proteins increases the relaxivity of Mn2+ and enhances the contrast. We show that these nanoparticles could rapidly and selectively brighten solid tumours, identify hypoxic regions within the tumour mass and detect invisible millimetre-sized metastatic tumours in the liver.

  7. Subharmonic Imaging and Pressure Estimation for Monitoring Neoadjuvant Chemotherapy

    DTIC Science & Technology

    2015-11-01

    ultrasound contrast agents to improve the monitoring of breast cancer treatment response to neoadjuvant therapies in women diagnosed with LABC by imaging...estimation (SHAPE). Software for analyzing RF data from a Logiq 9 ultrasound scanner (GE Healthcare, Milwauke, WI) to produce 3D SHAPE pressure...responders; albeit not statistically significant (p > 0.19). 14. SUBJECT TERMS Breast Cancer, Ultrasound Imaging, Ultrasound Contrast Agent, Pressure

  8. A new contrast media for functional MR urography: Gd-MAG3.

    PubMed

    Algin, Oktay

    2011-07-01

    Tc-99m-MAG3 (tubular agent) provides high imaging quality and extraction efficiency; and has become one of the most widely used agent for scintigraphic examinations of urinary system pathologies and renal transplants. Recently, it was reported that functional magnetic resonance urography (FMRU) can be sufficient in detection of urinary tract obstruction, renal artery stenosis, calculation of kidney functions and evaluation of renal transplants. However the pharmacokinetics of magnetic resonance (MR) contrast-media used in FMRU and Tc-99m-MAG3 differs from each other. This may cause discordant results between the FMRU and most of the scintigraphic studies. To our knowledge, there is no contrast-media which is specific for FMRU. A kidney specific contrast material can be developed for FMRU studies as well. MAG3 is a good candidate for this chelation. In conclusion, MR imaging (MRI) will be the most useful and important technique for morphologic-functional evaluation of urinary system. FMRU examinations performed with MAG3 chelated gadolinium can be sufficient for the complete evaluation of urinary tract even in patients with impaired renal functions ("all in one MRI"). MRI has some important advantages including no risk for radiation exposure, high temporal and spatial resolution, no need for nephrotoxic contrast agent; besides being a fast and feasible technique. Gadolinium-containing contrast agents may cause a life-threatening adverse reaction known as nephrogenic systemic fibrosis in patients with severe renal impairment, but Gd-MAG3 may reduce the risk of nephrogenic systemic fibrosis due to its higher extraction capacity and other features. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. The in vivo relaxivity of MRI contrast agents

    NASA Astrophysics Data System (ADS)

    Shuter, Borys

    1999-11-01

    Post-contrast clinical 1H Magnetic Resonance Images have to date been interpreted with little regard for possible variations in the in-vivo properties of injected magnetic pharmaceuticals (contrast agents), particularly in their relaxivity or ability to alter tissue relaxation rates, T2-1 and T 2-1, per unit concentration. The relaxivities of contrast agents have only rarely been measured in-vivo, measurements usually being performed on excised tissues and at magnetic field strengths lower than used in clinical practice. Some researchers have simply assumed that relaxivities determined in homogeneous tissue phantoms were applicable in-vivo. In this thesis, the relaxivities of two contrast agents, Gd-DTPA and Gd-EOB-DTPA, were measured in simple tissue phantoms and in the kidney and liver of intact, but sacrificed, Wistar rats using a clinical MR scanner with a magnetic field of 1.5 Tesla. T1 and T2 were determined from sets of images acquired using a standard clinical spin-echo pulse sequence. The contrast agent concentration in tissue was assessed by radioassay of 153Gd-DTPA or 153Gd-EOB-DTPA, mixed with the normal compound prior to injection. Relaxivity was taken as the slope of a linear regression fit of relaxation rate against Gd concentration. The relaxivities of Gd-EOB-DTPA were similarly determined in normal and biliary- obstructed guinea pigs. Relaxivities in tissue differed significantly from values obtained in simple phantoms. Kidney T1 relaxivity was reduced for both compounds in normal animals. Three days or more of biliary obstruction produced further reductions in kidney T1 relaxivity of Gd-EOB-DTPA, providing strong evidence that disease affects contrast agent relaxivity. Kidney T2 relaxivity was much greater than T1 relaxivity and was also depressed by biliary obstruction. Liver T1 and T 2 relaxivites were increased above phantom values, but were not affected by the biliary obstruction. Water compartmentalisation, macromolecular binding, proton diffusion in magnetic field gradients due to susceptibility differences and cross-relaxation were considered as possible explanations for the findings. From the relaxivity results it follows that unless actual tissue relaxivities are used, estimates of tissue magnetopharmaceutical concentration made from enhancement of MR signal will be significantly in error, as will derived estimates of clinically useful parameters such as tissue perfusion.

  10. Examining multi-component DNA-templated nanostructures as imaging agents

    NASA Astrophysics Data System (ADS)

    Jaganathan, Hamsa

    2011-12-01

    Magnetic resonance imaging (MRI) is the leading non-invasive tool for disease imaging and diagnosis. Although MRI exhibits high spatial resolution for anatomical features, the contrast resolution is low. Imaging agents serve as an aid to distinguish different types of tissues within images. Gadolinium chelates, which are considered first generation designs, can be toxic to health, while ultra-small, superparamagnetic nanoparticles (NPs) have low tissue-targeting efficiency and rapid bio-distribution, resulting to an inadequate detection of the MRI signal and enhancement of image contrast. In order to improve the utility of MRI agents, the challenge in composition and structure needs to be addressed. One-dimensional (1D), superparamagnetic nanostructures have been reported to enhance magnetic and in vivo properties and therefore has a potential to improve contrast enhancement in MRI images. In this dissertation, the structure of 1D, multi-component NP chains, scaffolded on DNA, were pre-clinically examined as potential MRI agents. First, research was focused on characterizing and understanding the mechanism of proton relaxation for DNA-templated NP chains using nuclear magnetic resonance (NMR) spectrometry. Proton relaxation and transverse relaxivity were higher in multi-component NP chains compared to disperse NPs, indicating the arrangement of NPs on a 1D structure improved proton relaxation sensitivity. Second, in vitro evaluation for potential issues in toxicity and contrast efficiency in tissue environments using a 3 Tesla clinical MRI scanner was performed. Cell uptake of DNA-templated NP chains was enhanced after encapsulating the nanostructure with layers of polyelectrolytes and targeting ligands. Compared to dispersed NPs, DNA-templated NP chains improved MRI contrast in both the epithelial basement membrane and colon cancer tumors scaffolds. The last part of the project was focused on developing a novel MRI agent that detects changes in DNA methylation levels. The findings from this dissertation suggest that the structural arrangement of NPs on DNA significantly influenced their function and utility as MRI agents.

  11. Use of gadolinium-based magnetic resonance imaging contrast agents and awareness of brain gadolinium deposition among pediatric providers in North America.

    PubMed

    Mithal, Leena B; Patel, Payal S; Mithal, Divakar; Palac, Hannah L; Rozenfeld, Michael N

    2017-05-01

    Numerous recent articles have reported brain gadolinium deposition when using linear but not macrocyclic gadolinium-based contrast agents (GBCAs). To determine the current landscape of gadolinium use among pediatric institutions and the knowledge base of radiologists and referring providers with regard to GBCAs and brain gadolinium deposition. We e-mailed voluntary closed surveys to 5,390 physicians in various pediatric professional societies between January 2016 and March 2016. We used chi-square and Fisher exact tests to compare response distributions among specialties. We found that 80% of surveyed pediatric hospitals use macrocyclic contrast agents. In the last year, 58% switched their agent, most commonly to gadoterate meglumine, with the most common reason being brain gadolinium deposition. Furthermore, surveys indicated that 23% of hospitals are considering switching, and, of these, 83% would switch to gadoterate meglumine; the most common reasons were brain gadolinium deposition and safety. Radiologists were more aware of brain gadolinium deposition than non-radiologist physicians (87% vs. 26%; P<0.0001). Radiologists and referring providers expressed similar levels of concern (95% and 89%). Twelve percent of radiologists and 2% of referring providers reported patients asking about brain gadolinium deposition. Radiologists were significantly more comfortable addressing patient inquiries than referring pediatric physicians (48% vs. 6%; P<0.0001). The number of MRIs requested by referring pediatric physicians correlated with their knowledge of brain gadolinium deposition, contrast agent used by their hospital, and comfort discussing brain gadolinium deposition with patients (P<0.0001). Since the discovery of brain gadolinium deposition, many pediatric hospitals have switched to or plan to switch to a more stable macrocyclic MR contrast agent, most commonly gadoterate meglumine. Despite this, there is need for substantial further education of radiologists and referring pediatric providers regarding GBCAs and brain gadolinium deposition.

  12. Revitalizing the drug pipeline: AntibioticDB, an open access database to aid antibacterial research and development.

    PubMed

    Farrell, L J; Lo, R; Wanford, J J; Jenkins, A; Maxwell, A; Piddock, L J V

    2018-06-11

    The current state of antibiotic discovery, research and development is insufficient to respond to the need for new treatments for drug-resistant bacterial infections. The process has changed over the last decade, with most new agents that are in Phases 1-3, or recently approved, having been discovered in small- and medium-sized enterprises or academia. These agents have then been licensed or sold to large companies for further development with the goal of taking them to market. However, early drug discovery and development, including the possibility of developing previously discontinued agents, would benefit from a database of antibacterial compounds for scrutiny by the developers. This article describes the first free, open-access searchable database of antibacterial compounds, including discontinued agents, drugs under pre-clinical development and those in clinical trials: AntibioticDB (AntibioticDB.com). Data were obtained from publicly available sources. This article summarizes the compounds and drugs in AntibioticDB, including their drug class, mode of action, development status and propensity to select drug-resistant bacteria. AntibioticDB includes compounds currently in pre-clinical development and 834 that have been discontinued and that reached varying stages of development. These may serve as starting points for future research and development.

  13. Cell-permeable Ln(III) chelate-functionalized InP quantum dots as multimodal imaging agents.

    PubMed

    Stasiuk, Graeme J; Tamang, Sudarsan; Imbert, Daniel; Poillot, Cathy; Giardiello, Marco; Tisseyre, Céline; Barbier, Emmanuel L; Fries, Pascal Henry; de Waard, Michel; Reiss, Peter; Mazzanti, Marinella

    2011-10-25

    Quantum dots (QDs) are ideal scaffolds for the development of multimodal imaging agents, but their application in clinical diagnostics is limited by the toxicity of classical CdSe QDs. A new bimodal MRI/optical nanosized contrast agent with high gadolinium payload has been prepared through direct covalent attachment of up to 80 Gd(III) chelates on fluorescent nontoxic InP/ZnS QDs. It shows a high relaxivity of 900 mM(-1) s(-1) (13 mM(-1 )s(-1) per Gd ion) at 35 MHz (0.81 T) and 298 K, while the bright luminescence of the QDs is preserved. Eu(III) and Tb(III) chelates were also successfully grafted to the InP/ZnS QDs. The absence of energy transfer between the QD and lanthanide emitting centers results in a multicolor system. Using this convenient direct grafting strategy additional targeting ligands can be included on the QD. Here a cell-penetrating peptide has been co-grafted in a one-pot reaction to afford a cell-permeable multimodal multimeric MRI contrast agent that reports cellular localization by fluorescence and provides high relaxivity and increased tissue retention with respect to commercial contrast agents.

  14. Contrast-enhanced ultrasound evaluation of pancreatic cancer xenografts in nude mice after irradiation with sub-threshold focused ultrasound for tumor ablation

    PubMed Central

    Wang, Rui; Guo, Qian; Chen, Yi Ni; Hu, Bing; Jiang, Li Xin

    2017-01-01

    We evaluated the efficacy of contrast-enhanced ultrasound for assessing tumors after irradiation with sub-threshold focused ultrasound (FUS) ablation in pancreatic cancer xenografts in nude mice. Thirty tumor-bearing nude mice were divided into three groups: Group A received sham irradiation, Group B received a moderate-acoustic energy dose (sub-threshold), and Group C received a high-acoustic energy dose. In Group B, B-mode ultrasound (US), color Doppler US, and dynamic contrast-enhanced ultrasound (DCE-US) studies were conducted before and after irradiation. After irradiation, tumor growth was inhibited in Group B, and the tumors shrank in Group C. In Group A, the tumor sizes were unchanged. In Group B, contrast-enhanced ultrasound (CEUS) images showed a rapid rush of contrast agent into and out of tumors before irradiation. After irradiation, CEUS revealed contrast agent perfusion only at the tumor periphery and irregular, un-perfused volumes of contrast agent within the tumors. DCE-US perfusion parameters, including peak intensity (PI) and area under the curve (AUC), had decreased 24 hours after irradiation. PI and AUC were increased 48 hours and 2weeks after irradiation. Time to peak (TP) and sharpness were increased 24 hours after irradiation. TP decreased at 48 hours and 2 weeks after irradiation. CEUS is thus an effective method for early evaluation after irradiation with sub-threshold FUS. PMID:28402267

  15. Retrospective analysis of patients for development of nephrogenic systemic fibrosis following conventional angiography using gadolinium-based contrast agents.

    PubMed

    Hoppe, Hanno; Spagnuolo, Sara; Froehlich, Johannes M; Nievergelt, Helga; Dinkel, Hans-Peter; Gretener, Silvia; Thoeny, Harriet C

    2010-03-01

    The purpose was to retrospectively review the data of 27 patients with renal insufficiency who underwent conventional angiography with gadolinium-based contrast agents (GDBCA) as alternative contrast agents and assess the occurrence of nephrogenic systemic fibrosis (NSF) together with associated potential risk factors. This HIPAA-compliant study had institutional review board approval, and informed consent was waived. Statistical analysis was performed for all available laboratory and clinical data, including dermatology reports. Type and amount of the GDBCA used were recorded for angiography and additional MRI studies, if applicable. Serum creatinine levels (SCr) pre- and post-angiography were recorded, and estimated glomerular filtration rates (eGFR) were calculated. Ten female and 17 male patients who underwent angiography with GDBCA were included. The mean amount of GDBCA administered was 44 +/- 15.5 ml (range 15-60 ml) or 0.24 + 0.12 mmol/kg (range 0.1-0.53 mmol/kg). At the time of angiography all patients had renal insufficiency (eGFR <60 ml/min/1.73 m(2)). Mean eGFR pre-angiography was 26 ml/min/1.73 m(2) and 33 ml/min/1.73 m(2) post-angiography. The mean follow-up period covers 28 months, range 1-84 months. Additional MRI studies with GDBCA administration were performed in 15 patients. One patient with typical skin lesions had developed biopsy-confirmed NSF. Conventional arterial angiography with GDBCA may play a role in the development of NSF in patients with renal insufficiency. Alternative contrast agents, such as CO(2) angiography or rather the use of low doses of iodinated contrast agents, should be considered in these patients.

  16. Magnetic resonance cholangiopancreatography (MRCP) using new negative per-oral contrast agent based on superparamagnetic iron oxide nanoparticles for extrahepatic biliary duct visualization in liver cirrhosis.

    PubMed

    Polakova, Katerina; Mocikova, Ingrid; Purova, Dana; Tucek, Pavel; Novak, Pavel; Novotna, Katerina; Izak, Niko; Bielik, Radoslav; Zboril, Radek; Miroslav, Herman

    2016-12-01

    Magnetic resonance cholangiopancreatography (MRCP) is often used for imaging of the biliary tree and is required by surgeons before liver transplantation. Advanced liver cirrhosis and ascites in patients however present diagnostic problems for MRCP. The aim of this study was to find out if the use of our negative per-oral contrast agent containing superparamagnetic iron oxide nanoparticles (SPIO) in MRCP is helpful for imaging of hepatobiliary tree in patients with liver cirrhosis. Forty patients with liver cirrhosis were examined on a 1.5 T MR unit using standard MRCP protocol. Twenty patients (group A) underwent MRCP after administration of per-oral SPIO contrast agent 30 min before examination. In group B, twenty patients were examined without per-oral bowel preparation. Ascites was present in eleven patients from group A and in thirteen patients in group B. Four radiologists analyzed MR images for visibility and delineation of the biliary tree. χ 2 tests were used for comparison of the visibility of intrahepatic and extrahepatic biliary ducts in patients with and without ascites. Better extrahepatic biliary duct visualization and visibility of extraluminal pathologies in patients with ascites was proved after administration of SPIO contrast agent. No statistically significant difference between group A and B was found for visualization of extrahepatic biliary ducts in patients without ascites. Delineation of intrahepatic biliary ducts was independent on bowel preparation. Application of our negative per-oral SPIO contrast agent before MRCP improves the visualization of extrahepatic biliary ducts in patients with ascites which is helpful during the liver surgery, mainly in liver transplantation.

  17. Effect of obstructive jaundice on hepatic hemodynamics: use of Sonazoid-enhanced ultrasonography in a prospective study of the blood flow balance between the hepatic portal vein and hepatic artery.

    PubMed

    Wakui, Noritaka; Takeda, Yuki; Nishinakagawa, Shuta; Ueki, Nobuo; Otsuka, Takafumi; Oba, Nobuyuki; Hashimoto, Hiroshi; Kamiyama, Naohisa; Sumino, Yasukiyo; Kojima, Tatsuya

    2015-10-01

    To prospectively clarify the effects of obstructive jaundice (OJ) on hepatic hemodynamics using contrast-enhanced ultrasonography (US). Subjects comprised 14 patients admitted to our hospital for OJ between April 2013 and March 2014. Contrast-enhanced US was performed using the LOGIQ E9 ultrasound device during the jaundice phase, before biliary drainage, and again after improvement of jaundice. After injecting the Sonazoid contrast agent, contrast dynamics were recorded in the right kidney and liver segments 5 or 6. Prototype software was used to calculate mean arrival time (AT) of the contrast agent in the liver parenchyma. Statistical analysis was performed to compare the mean AT in the jaundice and improved jaundice phases. We were unable to follow up three of the 14 patients after biliary drainage; thus, we included 11 patients for further analysis. The mean AT of the contrast agent was 2.0 ± 1.8 and 6.1 ± 2.3 s in the jaundice and improved jaundice phases, respectively, showing significantly shorter AT in the jaundice phase (p = 0.0033). Our findings indicate that OJ may influence the blood flow balance between the hepatic portal vein and hepatic artery.

  18. 4-D spatiotemporal analysis of ultrasound contrast agent dispersion for prostate cancer localization: a feasibility study.

    PubMed

    Schalk, Stefan G; Demi, Libertario; Smeenge, Martijn; Mills, David M; Wallace, Kirk D; de la Rosette, Jean J M C H; Wijkstra, Hessel; Mischi, Massimo

    2015-05-01

    Currently, nonradical treatment for prostate cancer is hampered by the lack of reliable diagnostics. Contrastultrasound dispersion imaging (CUDI) has recently shown great potential as a prostate cancer imaging technique. CUDI estimates the local dispersion of intravenously injected contrast agents, imaged by transrectal dynamic contrast-enhanced ultrasound (DCE-US), to detect angiogenic processes related to tumor growth. The best CUDI results have so far been obtained by similarity analysis of the contrast kinetics in neighboring pixels. To date, CUDI has been investigated in 2-D only. In this paper, an implementation of 3-D CUDI based on spatiotemporal similarity analysis of 4-D DCE-US is described. Different from 2-D methods, 3-D CUDI permits analysis of the entire prostate using a single injection of contrast agent. To perform 3-D CUDI, a new strategy was designed to estimate the similarity in the contrast kinetics at each voxel, and data processing steps were adjusted to the characteristics of 4-D DCE-US images. The technical feasibility of 4-D DCE-US in 3-D CUDI was assessed and confirmed. Additionally, in a preliminary validation in two patients, dispersion maps by 3-D CUDI were quantitatively compared with those by 2-D CUDI and with 12-core systematic biopsies with promising results.

  19. Paramagnetic and fluorescent liposomes for target-specific imaging and therapy of tumor angiogenesis

    PubMed Central

    Kluza, Ewelina; Van Tilborg, Geralda A. F.; van der Schaft, Daisy W. J.; Griffioen, Arjan W.; Mulder, Willem J. M.; Nicolay, Klaas

    2010-01-01

    Angiogenesis is essential for tumor growth and metastatic potential and for that reason considered an important target for tumor treatment. Noninvasive imaging technologies, capable of visualizing tumor angiogenesis and evaluating the efficacy of angiostatic therapies, are therefore becoming increasingly important. Among the various imaging modalities, magnetic resonance imaging (MRI) is characterized by a superb spatial resolution and anatomical soft-tissue contrast. Revolutionary advances in contrast agent chemistry have delivered versatile angiogenesis-specific molecular MRI contrast agents. In this paper, we review recent advances in the preclinical application of paramagnetic and fluorescent liposomes for noninvasive visualization of the molecular processes involved in tumor angiogenesis. This liposomal contrast agent platform can be prepared with a high payload of contrast generating material, thereby facilitating its detection, and is equipped with one or more types of targeting ligands for binding to specific molecules expressed at the angiogenic site. Multimodal liposomes endowed with contrast material for complementary imaging technologies, e.g., MRI and optical, can be exploited to gain important preclinical insights into the mechanisms of binding and accumulation at angiogenic vascular endothelium and to corroborate the in vivo findings. Interestingly, liposomes can be designed to contain angiostatic therapeutics, allowing for image-supervised drug delivery and subsequent monitoring of therapeutic efficacy. PMID:20390447

  20. Computed Tomography Imaging of Solid Tumors Using a Liposomal-Iodine Contrast Agent in Companion Dogs with Naturally Occurring Cancer.

    PubMed

    Ghaghada, Ketan B; Sato, Amy F; Starosolski, Zbigniew A; Berg, John; Vail, David M

    2016-01-01

    Companion dogs with naturally occurring cancer serve as an important large animal model in translational research because they share strong similarities with human cancers. In this study, we investigated a long circulating liposomal-iodine contrast agent (Liposomal-I) for computed tomography (CT) imaging of solid tumors in companion dogs with naturally occurring cancer. The institutional animal ethics committees approved the study and written informed consent was obtained from all owners. Thirteen dogs (mean age 10.1 years) with a variety of masses including primary and metastatic liver tumors, sarcomas, mammary carcinoma and lung tumors, were enrolled in the study. CT imaging was performed pre-contrast and at 15 minutes and 24 hours after intravenous administration of Liposomal-I (275 mg/kg iodine dose). Conventional contrast-enhanced CT imaging was performed in a subset of dogs, 90 minutes prior to administration of Liposomal-I. Histologic or cytologic diagnosis was obtained for each dog prior to admission into the study. Liposomal-I resulted in significant (p < 0.05) enhancement and uniform opacification of the vascular compartment. Non-renal, reticulo-endothelial systemic clearance of the contrast agent was demonstrated. Liposomal-I enabled visualization of primary and metastatic liver tumors. Sub-cm sized liver lesions grossly appeared as hypo-enhanced compared to the surrounding normal parenchyma with improved lesion conspicuity in the post-24 hour scan. Large liver tumors (> 1 cm) demonstrated a heterogeneous pattern of intra-tumoral signal with visibly higher signal enhancement at the post-24 hour time point. Extra-hepatic, extra-splenic tumors, including histiocytic sarcoma, anaplastic sarcoma, mammary carcinoma and lung tumors, were visualized with a heterogeneous enhancement pattern in the post-24 hour scan. The long circulating liposomal-iodine contrast agent enabled prolonged visualization of small and large tumors in companion dogs with naturally occurring cancer. The study warrants future work to assess the sensitivity and specificity of the Liposomal-I agent in various types of naturally occurring canine tumors.

  1. Nonlinear Dynamics of a Bubble Contrast Agent Oscillating near an Elastic Wall

    NASA Astrophysics Data System (ADS)

    Garashchuk, Ivan R.; Sinelshchikov, Dmitry I.; Kudryashov, Nikolay A.

    2018-05-01

    Contrast agent microbubbles, which are encapsulated gas bubbles, are widely used to enhance ultrasound imaging. There are also several new promising applications of the contrast agents such as targeted drug delivery and noninvasive therapy. Here we study three models of the microbubble dynamics: a nonencapsulated bubble oscillating close to an elastic wall, a simple coated bubble and a coated bubble near an elastic wall.We demonstrate that complex dynamics can occur in these models. We are particularly interested in the multistability phenomenon of bubble dynamics. We show that coexisting attractors appear in all of these models, but for higher acoustic pressures for the models of an encapsulated bubble.We demonstrate how several tools can be used to localize the coexisting attractors. We provide some considerations why the multistability can be undesirable for applications.

  2. Biocompatible Polyhydroxyethylaspartamide-based Micelles with Gadolinium for MRI Contrast Agents

    PubMed Central

    2010-01-01

    Biocompatible poly-[N-(2-hydroxyethyl)-d,l-aspartamide]-methoxypoly(ethyleneglycol)-hexadecylamine (PHEA-mPEG-C16) conjugated with 1,4,7,10-tetraazacyclododecan-1,4,7,10-tetraacetic acid-gadolinium (DOTA-Gd) via ethylenediamine (ED) was synthesized as a magnetic resonance imaging (MRI) contrast agent. Amphiphilic PHEA-mPEG-C16-ED-DOTA-Gd forms micelle in aqueous solution. All the synthesized materials were characterized by proton nuclear magnetic resonance (1H NMR). Micelle size and shape were examined by dynamic light scattering (DLS) and atomic force microscopy (AFM). Micelles with PHEA-mPEG-C16-ED-DOTA-Gd showed higher relaxivities than the commercially available gadolinium contrast agent. Moreover, the signal intensity of a rabbit liver was effectively increased after intravenous injection of PHEA-mPEG-C16-ED-DOTA-Gd. PMID:21170410

  3. A theoretical investigation of chirp insonification of ultrasound contrast agents.

    PubMed

    Barlow, Euan; Mulholland, Anthony J; Gachagan, Anthony; Nordon, Alison

    2011-08-01

    A theoretical investigation of second harmonic imaging of an Ultrasound Contrast Agent (UCA) under chirp insonification is considered. By solving the UCA's dynamical equation analytically, the effect that the chirp signal parameters and the UCA shell parameters have on the amplitude of the second harmonic frequency are examined. This allows optimal parameter values to be identified which maximise the UCA's second harmonic response. A relationship is found for the chirp parameters which ensures that a signal can be designed to resonate a UCA for a given set of shell parameters. It is also shown that the shell thickness, shell viscosity and shell elasticity parameter should be as small as realistically possible in order to maximise the second harmonic amplitude. Keller-Herring, Second Harmonic, Chirp, Ultrasound Contrast Agent. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Magnetic properties, water proton relaxivities, and in-vivo MR images of paramagnetic nanoparticles

    NASA Astrophysics Data System (ADS)

    Lee, Gang Ho; Chang, Yongmin

    2015-07-01

    In this mini review, magnetic resonance imaging (MRI) contrast agents based on lanthanideoxide (Ln2O3) nanoparticles are described. Ln2O3 (Ln = Gd, Dy, Ho, and Er) nanoparticles are paramagnetic, but show appreciable magnetic moments at room temperature and even at ultrasmall particle diameters. Among Ln2O3 nanoparticles, Gd2O3 nanoparticles show larger longitudinal water proton relaxivity (r1) values than Gd-chelates because of the large amount of Gd in the nanoparticle, and the other Ln2O3 nanoparticles (Ln = Dy, Ho, and Er) show appreciable transverse water proton relaxivity (r2) values. Therefore, Gd2O3 nanoparticles are potential T1 MRI contrast agents while the other Ln2O3 nanoparticles are potential T2 MRI contrast agents at high MR fields.

  5. Patients with advanced and metastatic renal cell carcinoma treated with targeted therapy in the Czech Republic: twenty cancer centres, six agents, one database.

    PubMed

    Poprach, Alexandr; Bortlíček, Zbyněk; Büchler, Tomáš; Melichar, Bohuslav; Lakomý, Radek; Vyzula, Rostislav; Brabec, Petr; Svoboda, Marek; Dušek, Ladislav; Gregor, Jakub

    2012-12-01

    The incidence and mortality of renal cell carcinoma (RCC) in the Czech Republic are among the highest in the world. Several targeted agents have been recently approved for the treatment of advanced/metastatic RCC. Presentation of a national clinical database for monitoring and assessment of patients with advanced/metastatic RCC treated with targeted therapy. The RenIS (RENal Information System, http://renis.registry.cz ) registry is a non-interventional post-registration database of epidemiological and clinical data of patients with RCC treated with targeted therapies in the Czech Republic. Twenty cancer centres eligible for targeted therapy administration participate in the project. As of November 2011, six agents were approved and reimbursed from public health insurance, including bevacizumab, everolimus, pazopanib, sorafenib, sunitinib, and temsirolimus. As of 10 October 2011, 1,541 patients with valid records were entered into the database. Comparison with population-based data from the Czech National Cancer Registry revealed that RCC patients treated with targeted therapy are significantly younger (median age at diagnosis 59 vs. 66 years). Most RenIS registry patients were treated with sorafenib and sunitinib, many patients sequentially with both agents. Over 10 % of patients were also treated with everolimus in the second or third line. Progression-free survival times achieved were comparable to phase III clinical trials. The RenIS registry has become an important tool and source of information for the management of cancer care and clinical practice, providing comprehensive data on monitoring and assessment of RCC targeted therapy on a national level.

  6. Insulin use increases risk of asthma but metformin use reduces the risk in patients with diabetes in a Taiwanese population cohort.

    PubMed

    Chen, Chiung-Zuei; Hsu, Chih-Hui; Li, Chung-Yi; Hsiue, Tzuen-Ren

    2017-12-01

    Recent reports have suggested that insulin promotes airway smooth muscle contraction and enhances airway hyperresponsiveness, which are cardinal features of asthma. In contrast, metformin can reduce both airway inflammatory and remodeling properties. However, these results are all from in vitro and animal studies. This study investigated whether diabetes and various antidiabetic agents associate with the risk of asthma. We used a retrospective population-based cohort study using Taiwan's National Health Insurance claim database from 2000 to 2010 and a Cox proportional hazards regression model to compare the incidence of asthma between patients with diabetes (n = 19,428) and a matched non-diabetic group (n = 38,856). We also used a case-control study nested from the above cohort including 1,982 incident cases of asthma and 1,982 age- and sex-matched controls. A time density sampling technique was used to assess the effects of various antidiabetic agents on the risk of asthma. The incidence of asthma was significantly higher in the diabetic cohort than that in the non-diabetic cohort after adjustment for age, sex, and obesity, with a hazard ratio of 1.30 (95% confidence interval [CI]: 1.24-1.38). Insulin was found to increase the risk of asthma among diabetic patients (odds ratio [OR] 2.23; 95% CI: 1.52-3.58). In contrast, the use of metformin correlated with a decreased risk of asthma (OR 0.75; 95% CI: 0.60-0.95). Individuals with diabetes are at an increased risk of asthma. Insulin may further increase the risk of asthma, but the risk could possibly be reduced by using metformin.

  7. Impact of introduction of an acute surgical unit on management and outcomes of small bowel obstruction.

    PubMed

    Musiienko, Anton M; Shakerian, Rose; Gorelik, Alexandra; Thomson, Benjamin N J; Skandarajah, Anita R

    2016-10-01

    The acute surgical unit (ASU) is a recently established model of care in Australasia and worldwide. Limited data are available regarding its effect on the management of small bowel obstruction. We compared the management of small bowel obstruction before and after introduction of ASU at a major tertiary referral centre. We hypothesized that introduction of ASU would correlate with improved patient outcomes. A retrospective review of prospectively maintained databases was performed over two separate 2-year periods, before and after the introduction of ASU. Data collected included demographics, co-morbidity status, use of water-soluble contrast agent and computed tomography. Outcome measures included surgical intervention, time to surgery, hospital length of stay, complications, 30-day readmissions, use of total parenteral nutrition, intensive care unit admissions and overall mortality. Total emergency admissions to the ASU increased from 2640 to 4575 between the two time periods. A total of 481 cases were identified (225 prior and 256 after introduction of ASU). Mortality decreased from 5.8% to 2.0% (P = 0.03), which remained significant after controlling for confounders with multivariate analysis (odds ratio = 0.24, 95% confidence interval 0.08-0.73, P = 0.012). The proportion of surgically managed patients increased (20.9% versus 32.0%, P = 0.003) and more operations were performed within 5 days from presentation (76.6% versus 91.5%, P = 0.02). Fewer patients received water-soluble contrast agent (27.1% versus 18.4%, P = 0.02), but more patients were investigated with a computed tomography (70.7% versus 79.7%, P = 0.02). The ASU model of care resulted in decreased mortality, shorter time to intervention and increased surgical management. Overall complications rate and length of stay did not change. © 2015 Royal Australasian College of Surgeons.

  8. Rich or poor: Who should pay higher tax rates?

    NASA Astrophysics Data System (ADS)

    Murilo Castro de Oliveira, Paulo

    2017-08-01

    A dynamic agent model is introduced with an annual random wealth multiplicative process followed by taxes paid according to a linear wealth-dependent tax rate. If poor agents pay higher tax rates than rich agents, eventually all wealth becomes concentrated in the hands of a single agent. By contrast, if poor agents are subject to lower tax rates, the economic collective process continues forever.

  9. Highly stabilized gadolinium chelates functionalized on metal nanoparticles as magnetic resonance imaging contrast agent

    NASA Astrophysics Data System (ADS)

    Siddiqui, Talha S.

    Magnetic resonance imaging (MRI) is a non-invasive method for imaging and diagnosing tissue damage, organ function and the vascular system. Magnevist(TM) a complex of diethylenetriaminepentaacetic acid (DTPA) and Gd3+ is a clinically approved contrast agent for MRI. A derivative of DTPA was formed by the addition of two cysteine groups (DTPA-L-Cys) through amide linkage. The Gd complex of this ligand bonds with the silver surfaces through the cysteine thiols. GdDTPA-L-Cys was bound to ˜10nm diameter Ag nanoparticles for use as a multifunctional MRI contrast agent. The ligand and complex were characterized by 1H and 13C NMR, ESI-MS and IR spectroscopy. The silver construct was characterized by TEM, TGA and UV-Vis absorption spectra. The per metal complex r1 relaxivity of GdDTPA-L-Cys{Ag} greater than that of Magnavist(TM) with the same molarity for both compounds. The synthesis of a DTPA derivative is described that allows it to bind to silver or gold nanoparticles through a single thiol linkage (DTPASH). The resulting Gd complex, GdDTPASH, was bound to Ag nanoparticles to create a single monolayer on the surface. The construct was further stabilized in buffered solution with the addition of a thiolated PEG chain. The highly stabilized nanoparticle construct delivers a high payload of Gd compelex and is an effective T1 brightening agent. The production of this type of construct opens the way for engineered multimodal MRI contrast agents.

  10. Pulse sequences for uniform perfluorocarbon droplet vaporization and ultrasound imaging.

    PubMed

    Puett, C; Sheeran, P S; Rojas, J D; Dayton, P A

    2014-09-01

    Phase-change contrast agents (PCCAs) consist of liquid perfluorocarbon droplets that can be vaporized into gas-filled microbubbles by pulsed ultrasound waves at diagnostic pressures and frequencies. These activatable contrast agents provide benefits of longer circulating times and smaller sizes relative to conventional microbubble contrast agents. However, optimizing ultrasound-induced activation of these agents requires coordinated pulse sequences not found on current clinical systems, in order to both initiate droplet vaporization and image the resulting microbubble population. Specifically, the activation process must provide a spatially uniform distribution of microbubbles and needs to occur quickly enough to image the vaporized agents before they migrate out of the imaging field of view. The development and evaluation of protocols for PCCA-enhanced ultrasound imaging using a commercial array transducer are described. The developed pulse sequences consist of three states: (1) initial imaging at sub-activation pressures, (2) activating droplets within a selected region of interest, and (3) imaging the resulting microbubbles. Bubble clouds produced by the vaporization of decafluorobutane and octafluoropropane droplets were characterized as a function of focused pulse parameters and acoustic field location. Pulse sequences were designed to manipulate the geometries of discrete microbubble clouds using electronic steering, and cloud spacing was tailored to build a uniform vaporization field. The complete pulse sequence was demonstrated in the water bath and then in vivo in a rodent kidney. The resulting contrast provided a significant increase (>15 dB) in signal intensity. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Balancing stealth and echogenic properties in an ultrasound contrast agent with drug delivery potential.

    PubMed

    Jablonowski, Lauren J; Alfego, David; Andorko, James I; Eisenbrey, John R; Teraphongphom, Nutte; Wheatley, Margaret A

    2016-10-01

    Contrast agents are currently being modified to combine diagnostic and therapeutic capabilities. For ultrasound (US) imaging with polymeric contrast agents, it is necessary to modify the shell to create "stealth" microbubbles but without these modifications sacrificing the agent's ability to interact with the focused US beam. We hypothesize that addition of the classic immune shielding molecule polyethylene glycol (PEG) to a polylactide (PLA) microbubble shell will affect the acoustic and physical properties of the resulting agents. In an effort to determine the best formulation to achieve a balance between stealth and acoustic activity, we compared two PEGylation techniques; addition of increasing amounts of PEG-PLA copolymer and employing incorporation of a PEG lipid (LipidPEG) into the shell. Loss of acoustic enhancement occurred in a dose-dependent manner for both types of PEGylated agents (loss of signal occurred at >5 wt% PEG-PLA and >1 wt% LipidPEG), while immune activation was also reduced in a dose-dependent manner for the PEG-PLA agents. This study shows that the balance between acoustic behavior and improved immune avoidance was scalable and successful to different degrees with both PEGylation methods, and was best achieved using for PEG-PLA at 5 wt% and for LipidPEG at 1 wt%. Studies are ongoing to evaluate the best method for the targeting and drug delivery capabilities of these agents for applications in cancer treatment. This study represents the basis for understanding the consequences of making modifications to the native polymeric shell. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. A New Approach in the Preparation of Dendrimer-Based Bifunctional Diethylenetriaminepentaacetic Acid MR Contrast Agent Derivatives

    PubMed Central

    Nwe, Kido; Xu, Heng; Regino, Celeste Aida S.; Bernardo, Marcelino; Ileva, Lilia; Riffle, Lisa; Wong, Karen J.; Brechbiel, Martin W.

    2009-01-01

    In this paper we report a new method to prepare and characterize a contrast agent based on a fourth-generation (G4) polyamidoamine (PAMAM) dendrimer conjugated to the gadolinium complex of the bifunctional diethylenetriamine pentaacetic acid derivative (1B4M-DTPA). The method involves pre-forming the metal-ligand chelate in alcohol prior to conjugation to the dendrimer. The dendrimer-based agent was purified by a Sephadex® G-25 column and characterized by elemental analysis. The analysis and SEHPLC data gave a chelate to dendrimer ratio of 30:1 suggesting conjugation at approximately every other amine terminal on the dendrimer. Molar relaxivity of the agent measured at pH 7.4 displayed a higher value than that of the analogous G4 dendrimer based agent prepared by the post-metal incorporation method (r1 = 26.9 vs. 13.9 mM-1s-1 at 3T and 22°C). This is hypothesized to be due to the higher hydrophobicity of this conjugate, and the lack of available charged carboxylate groups from non-complexed free ligands that might coordinate to the metal and thus also reduce water exchange sites. Additionally, the distribution populations of compounds that result from the post-metal incorporation route are eliminated from the current product simplifying characterization as quality control issues pertaining to the production of such agents for clinical use as MR contrast agents. In vivo imaging in mice showed a reasonably fast clearance (t1/2 = 24 min) suggesting a viable agent for use in clinical application. PMID:19555072

  13. A new approach in the preparation of dendrimer-based bifunctional diethylenetriaminepentaacetic acid MR contrast agent derivatives.

    PubMed

    Nwe, Kido; Xu, Heng; Regino, Celeste Aida S; Bernardo, Marcelino; Ileva, Lilia; Riffle, Lisa; Wong, Karen J; Brechbiel, Martin W

    2009-07-01

    In this paper, we report a new method to prepare and characterize a contrast agent based on a fourth-generation (G4) polyamidoamine (PAMAM) dendrimer conjugated to the gadolinium complex of the bifunctional diethylenetriamine pentaacetic acid derivative (1B4M-DTPA). The method involves preforming the metal-ligand chelate in alcohol prior to conjugation to the dendrimer. The dendrimer-based agent was purified by a Sephadex G-25 column and characterized by elemental analysis. The analysis and SE-HPLC data gave a chelate to dendrimer ratio of 30:1 suggesting conjugation at approximately every other amine terminal on the dendrimer. Molar relaxivity of the agent measured at pH 7.4 displayed a higher value than that of the analogous G4 dendrimer based agent prepared by the postmetal incorporation method (r(1) = 26.9 vs 13.9 mM(-1) s(-1) at 3 T and 22 degrees C). This is hypothesized to be due to the higher hydrophobicity of this conjugate and the lack of available charged carboxylate groups from noncomplexed free ligands that might coordinate to the metal and thus also reduce water exchange sites. Additionally, the distribution populations of compounds that result from the postmetal incorporation route are eliminated from the current product simplifying characterization as quality control issues pertaining to the production of such agents for clinical use as MR contrast agents. In vivo imaging in mice showed a reasonably fast clearance (t(1/2) = 24 min) suggesting a viable agent for use in clinical application.

  14. New imaging technology: measurement of myocardial perfusion by contrast echocardiography

    NASA Technical Reports Server (NTRS)

    Rubin, D. N.; Thomas, J. D.

    2000-01-01

    Myocardial perfusion imaging has long been a goal for the non-invasive echocardiographic assessment of the heart. However, many factors at play in perfusion imaging have made this goal elusive. Harmonic imaging and triggered imaging with newer contrast agents have made myocardial perfusion imaging potentially practical in the very near future. The application of indicator dilution theory to the coronary circulation and bubble contrast agents is fraught with complexities and sources of error. Therefore, quantification of myocardial perfusion by non-invasive echocardiographic imaging requires further investigation in order to make this technique clinically viable.

  15. Metal-oxo containing polymer nanobeads as potential contrast agents for magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Pablico, Michele Huelar

    Magnetic resonance imaging (MRI) has greatly revolutionized the way diseases are detected and treated, as it is a non-invasive imaging modality solely based on the interaction of radiowaves and hydrogen nuclei in the presence of an external magnetic field. It is widely used today for the diagnosis of diseases as it offers an efficient method of mapping structure and function of soft tissues in the body. Most MRI examinations utilize paramagnetic materials known as contrast agents, which enhance the MR signal by decreasing the longitudinal (T1) and transverse (T2) relaxation times of the surrounding water protons in biological systems. This results into increased signal intensity differences thereby allowing better interpretation and analysis of pathological tissues. Contrast agents function by lowering the T1 or lowering the T2, resulting into bright and dark contrasts, respectively. The most common MRI contrast agents that are in clinical use today are gadolinium chelates and superparamagnetic iron oxide nanoparticles, both of which have their own advantages in terms of contrast enhancement properties. In the past few years, however, there has been interest in utilizing metal-containing clusters for MRI contrast enhancement as these materials bridge the gap between the constrained structure and magnetic properties of the gadolinium chelates with the superparamagnetic behavior of the iron oxide nanoparticles. Recently, metallic clusters containing Mn and Fe metal centers have received increased attention mainly because of their potential for high spin states and benign nature. In the quest to further develop novel imaging agents, this research has focused on investigating the use of metal-oxo clusters as potential contrast agents for MRI. The primary goal of this project is to identify clusters that meet the following criteria: high paramagnetic susceptibility, water-soluble, stable, cheap, contain environmentally benign metals, and easily derivatized. This work is also directed at developing metal-oxo containing hybrid materials using first row transition metals with potential catalytic and magnetic properties as well. We report several screened metal-oxo clusters but this study has centered on the mixed-metal oxo cluster, Mn8Fe4O 12(O2CCH3)16(H2O)4 or Mn8Fe4, mainly because it is highly paramagnetic and is soluble and stable in water. The cluster was screened for potential MRI contrast and was found to be a very promising T2 contrast agent with relaxivity values of r1 = 2.3 mM-1s -1 and r2 = 29.5 mM-1s-1. Initial cell studies on two human prostate cancer cell lines, DU-145 and LNCap, reveal that the cluster has low cytotoxicity and may be potentially used in vivo. One key advantage of Mn8Fe4 is its ability to undergo ligand exchange reactions, thus providing a mechanism for grafting to a variety of supports. By substituting the acetate groups on Mn8Fe4 with polymerizable ligands, we are able to form monodisperse magnetic polymer nanobeads (˜70 nm diameter) via the miniemulsion polymerization technique. To render the nanobead suitable for future in vivo experiments, we coated the surface with biocompatible polysaccharide dextran (40 kDa). Interestingly, relaxivity measurements and MRI studies show that encapsulating the Mn8Fe4 core within a polymer matrix decreased T 2 effects resulting in a positive T1 contrast enhancement. The resulting hybrid particles have the potential for further surface functionalization (i.e., therapeutic drugs, targeting moiety, fluorescent probe, etc.) making them a promising tool for biomedicine.

  16. Improved Peritoneal Cavity and Abdominal Organ Imaging Using a Biphasic Contrast Agent Protocol and Spectral Photon Counting Computed Tomography K-Edge Imaging.

    PubMed

    Si-Mohamed, Salim; Thivolet, Arnaud; Bonnot, Pierre-Emmanuel; Bar-Ness, Daniel; Képénékian, Vahan; Cormode, David P; Douek, Philippe; Rousset, Pascal

    2018-05-23

    To validate in vitro the capability of a high-spatial-resolution prototype spectral photon-counting computed tomography (SPCCT) scanner to differentiate between 2 contrast agents and to assess in vivo the image quality and the feasibility to image the peritoneal cavity in rats using the 2 contrast agents simultaneously within the vascular and peritoneal compartments. The authors performed SPCCT imaging (100 mAs, 120 kVp) with energy bin thresholds set to 30, 51, 64, 72, and 85 keV in vitro on a custom-made polyoxymethylene cylindrical phantom consisting of tubes with dilutions of both contrast agents and in vivo on 2 groups of adult rats using 2 injection protocols. Approval from the institutional animal ethics committee was obtained. One group received macrocylic gadolinium chelate intraperitoneal (IP) and iodine intravenous (IV) injections (protocol A, n = 3), whereas the second group received iodine IP and gadolinium IV (protocol B, n = 3). Helical scans were performed 35 minutes after IP injection and 20 seconds after IV injection. The SPCCT and contrast material images, that is, iodine and gadolinium maps, were reconstructed with a field of view of 160 mm, an isotropic voxel size of 250 μm, and a matrix size of 640 × 640 pixels using a soft reconstruction kernel. The SPCCT images were reconstructed with 2 different spatial resolutions to compare the image quality (sharpness, diagnostic quality, and organ visualization) of SPCCT (250 μm) with single-energy computed tomography (CT) (600 μm). Two radiologists evaluated the peritoneal opacification index in 13 regions (score = 0-3 per region) on each type of image. Concentrations of contrast agents were measured in the organs of interest. In vitro, the concentration measurements correlated well with the expected concentrations. The linear regressions both had R values of 0.99, slopes of 0.84 and 0.87, and offsets at -0.52 and -0.38 mg/mL for iodine and gadolinium, respectively. In vivo, the SPCCT images were of better diagnostic quality, with increased sharpness compared with the CT-like images (P < 0.0001). Intraperitoneal diffusion was excellent, with similar peritoneal opacification index on SPCCT images and overlay of contrast material maps (P = 1) without a significant difference between protocol A (37.0 ± 1.7) and protocol B (35.3 ± 1.5) (P = 0.34). Only the contrast material maps demonstrated clear visual separation of the contrast agents, allowing specific quantification of the physiological enhancement in the liver, spleen, and kidney and the urinary clearance in the renal pelvis and bladder. Renal excretion of the contrast agents injected IP was observed and was consistent with blood diffusion. Spectral photon-counting CT can be used to perform a complete peritoneal dual-contrast protocol, enabling a good assessment of the peritoneal cavity and abdominal organs in rats.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.

  17. Synthesis route and three different core-shell impacts on magnetic characterization of gadolinium oxide-based nanoparticles as new contrast agents for molecular magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Azizian, Gholamreza; Riyahi-Alam, Nader; Haghgoo, Soheila; Moghimi, Hamid Reza; Zohdiaghdam, Reza; Rafiei, Behrooz; Gorji, Ensieh

    2012-10-01

    Despite its good resolution, magnetic resonance imaging intrinsically has low sensitivity. Recently, contrast agent nanoparticles have been used as sensitivity and contrast enhancer. The aim of this study was to investigate a new controlled synthesis method for gadolinium oxide-based nanoparticle preparation. For this purpose, diethyleneglycol coating of gadolinium oxide (Gd2O3-DEG) was performed using new supervised polyol route, and small particulate gadolinium oxide (SPGO) PEGylation was obtained with methoxy-polyethylene-glycol-silane (550 and 2,000 Da) coatings as SPGO-mPEG-silane550 and 2,000, respectively. Physicochemical characterization and magnetic properties of these three contrast agents in comparison with conventional Gd-DTPA were verified by dynamic light scattering transmission electron microscopy, Fourier transform infrared spectroscopy, inductively coupled plasma, X-ray diffraction, vibrating sample magnetometer, and the signal intensity and relaxivity measurements were performed using 1.5-T MRI scanner. As a result, the nanoparticle sizes of Gd2O3-DEG, SPGO-mPEG-silane550, and SPGO-mPEG-silane2000 could be reached to 5.9, 51.3, 194.2 nm, respectively. The image signal intensity and longitudinal ( r 1) and transverse relaxivity ( r 2) measurements in different concentrations (0.3 to approximately 2.5 mM), revealed the r 2/ r 1 ratios of 1.13, 0.89, 33.34, and 33.72 for Gd-DTPA, Gd2O3-DEG, SPGO-mPEG-silane550, and SPGO-mPEG-silane2000, respectively. The achievement of new synthesis route of Gd2O3-DEG resulted in lower r 2/ r 1 ratio for Gd2O3-DEG than Gd-DTPA and other previous synthesized methods by this and other groups. The smaller r 2/ r 1 ratios of two PEGylated-SPGO contrast agents in our study in comparison with r 2/ r 1 ratio of previous PEGylation ( r 2/ r 1 = 81.9 for mPEG-silane 6,000 MW) showed that these new three introduced contrast agents could potentially be proper contrast enhancers for cellular and molecular MR imaging.

  18. Study and Characterization of Subharmonic Emissions by Using Shaped Ultrasonic Driving Pulse

    NASA Astrophysics Data System (ADS)

    Masotti, L.; Biagi, E.; Breschi, L.; Vannacci, E.

    Subharmonic emissions from Ultrasound Contrast Agents (UCAs) were studied by a Pulse Inversion method in order to assess the feasibility of implementation of this technique to subharmonic imaging. Interesting results concerning the dependence of the subharmonic emission with respect to initial pulse shape are presented. The experimentation was performed also by varying the acoustic pressure and concentration of the contrast agent (SonoVue®)

  19. Magnetic Resonance Imaging of Tumors with the Use of Iron Oxide Magnetic Nanoparticles as a Contrast Agent.

    PubMed

    Semkina, A S; Abakumov, M A; Grinenko, N F; Lipengolts, A A; Nukolova, N V; Chekhonin, V P

    2017-04-01

    We studied the possibility of using BSA-coated magnetic iron oxide nanoparticles for magnetic resonance imaging diagnosis of C6 glioblastoma, 4T1 mammary adenocarcinoma, and RS-1 hepatic mucous carcinoma. In all three cases, magnetic nanoparticles accumulated in the tumor and its large vessels. Magnetic resonance imaging with contrast agent allows visualization of the tumor tissue and its vascularization.

  20. Low-amplitude non-linear volume vibrations of single microbubbles measured with an "acoustical camera".

    PubMed

    Renaud, Guillaume; Bosch, Johan G; Van Der Steen, Antonius F W; De Jong, Nico

    2014-06-01

    Contrast-enhanced ultrasound imaging is based on the detection of non-linear vibrational responses of a contrast agent after its intravenous administration. Improving contrast-enhanced images requires an accurate understanding of the vibrational response to ultrasound of the lipid-coated gas microbubbles that constitute most ultrasound contrast agents. Variations in the volume of microbubbles provide the most efficient radiation of ultrasound and, therefore, are the most important bubble vibrations for medical diagnostic ultrasound imaging. We developed an "acoustical camera" that measures the dynamic volume change of individual microbubbles when excited by a pressure wave. In the work described here, the technique was applied to the characterization of low-amplitude non-linear behaviors of BR14 microbubbles (Bracco Research, Geneva, Switzerland). The amplitude dependence of the resonance frequency and the damping, the prevalence of efficient subharmonic and ultraharmonic vibrations and the amplitude dependence of the response at the fundamental frequency and at the second harmonic frequency were investigated. Because of the large number of measurements, we provide a statistical characterization of the low-amplitude non-linear properties of the contrast agent. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  1. Feasibility of spectral CT imaging for the detection of liver lesions with gold-based contrast agents - A simulation study.

    PubMed

    Müllner, Marie; Schlattl, Helmut; Hoeschen, Christoph; Dietrich, Olaf

    2015-12-01

    To demonstrate the feasibility of gold-specific spectral CT imaging for the detection of liver lesions in humans at low concentrations of gold as targeted contrast agent. A Monte Carlo simulation study of spectral CT imaging with a photon-counting and energy-resolving detector (with 6 energy bins) was performed in a realistic phantom of the human abdomen. The detector energy thresholds were optimized for the detection of gold. The simulation results were reconstructed with the K-edge imaging algorithm; the reconstructed gold-specific images were filtered and evaluated with respect to signal-to-noise ratio and contrast-to-noise ratio (CNR). The simulations demonstrate the feasibility of spectral CT with CNRs of the specific gold signal between 2.7 and 4.8 after bilateral filtering. Using the optimized bin thresholds increases the CNRs of the lesions by up to 23% compared to bin thresholds described in former studies. Gold is a promising new CT contrast agent for spectral CT in humans; minimum tissue mass fractions of 0.2 wt% of gold are required for sufficient image contrast. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  2. Target binding improves relaxivity in aptamer-gadolinium conjugates.

    PubMed

    Bernard, Elyse D; Beking, Michael A; Rajamanickam, Karunanithi; Tsai, Eve C; Derosa, Maria C

    2012-12-01

    MRI contrast agents (CA) have been heavily used over the past several decades to enhance the diagnostic value of the obtained images. From a design perspective, two avenues to improve the efficacy of contrast agents are readily evident: optimization of magnetic properties of the CA, and optimization of the pharmacokinetics and distribution of the CA in the patient. Contrast agents consisting of DNA aptamer-gadolinium(III) conjugates provide a single system in which these factors can be addressed simultaneously. In this proof-of-concept study, the 15mer thrombin aptamer was conjugated to diethylenetriaminepentaacetic (DTPA) dianhydride to form a monoamide derivative of the linear open-chain chelate present in the commonly used contrast agent Magnevist(®). The stability of the conjugated DNA aptamer-DTPA-Gd(III) chelate in a transmetallation study using Zn(II) was found to be similar to that reported for DTPA-Gd(III). Relaxivity enhancements of 35 ± 4 and 20 ± 1 % were observed in the presence of thrombin compared to a control protein at fields of 9.4 and 1.5 T, respectively. The inclusion of spacers between the aptamer and the DTPA to eliminate possible steric effects was also investigated but not found to improve the relaxation enhancement achieved in comparison to the unaltered aptamer conjugate.

  3. Trapping and dynamic manipulation of polystyrene beads mimicking circulating tumor cells using targeted magnetic/photoacoustic contrast agents

    NASA Astrophysics Data System (ADS)

    Wei, Chen-Wei; Xia, Jinjun; Pelivanov, Ivan; Hu, Xiaoge; Gao, Xiaohu; O'Donnell, Matthew

    2012-10-01

    Results on magnetically trapping and manipulating micro-scale beads circulating in a flow field mimicking metastatic cancer cells in human peripheral vessels are presented. Composite contrast agents combining magneto-sensitive nanospheres and highly optical absorptive gold nanorods were conjugated to micro-scale polystyrene beads. To efficiently trap the targeted objects in a fast stream, a dual magnet system consisting of two flat magnets to magnetize (polarize) the contrast agent and an array of cone magnets producing a sharp gradient field to trap the magnetized contrast agent was designed and constructed. A water-ink solution with an optical absorption coefficient of 10 cm-1 was used to mimic the optical absorption of blood. Magnetomotive photoacoustic imaging helped visualize bead trapping, dynamic manipulation of trapped beads in a flow field, and the subtraction of stationary background signals insensitive to the magnetic field. The results show that trafficking micro-scale objects can be effectively trapped in a stream with a flow rate up to 12 ml/min and the background can be significantly (greater than 15 dB) suppressed. It makes the proposed method very promising for sensitive detection of rare circulating tumor cells within high flow vessels with a highly absorptive optical background.

  4. Biocompatible astaxanthin as novel contrast agent for biomedical imaging.

    PubMed

    Nguyen, Van Phuc; Park, Suhyun; Oh, Junghwan; Wook Kang, Hyun

    2017-08-01

    Photoacoustic imaging (PAI) is a hybrid imaging modality with high resolution and sensitivity that can be beneficial for cancer staging. Due to insufficient endogenous photoacoustic (PA) contrast, the development of exogenous agents is critical in targeting cancerous tumors. The current study demonstrates the feasibility of marine-oriented material, astaxanthin, as a biocompatible PA contrast agent. Both silicon tubing phantoms and ex vivo bladder tissues are tested at various concentrations (up to 5 mg/ml) of astaxanthin to quantitatively explore variations in PA responses. A Q-switched Nd : YAG laser (λ = 532 nm) in conjunction with a 5 MHz ultrasound transducer is employed to generate and acquire PA signals from the samples. The phantom results presented that the PA signal amplitudes increase linearly with the astaxanthin concentrations (threshold detection = 0.31 mg/ml). The tissue injected with astaxanthin yields up to 16-fold higher PA signals, compared with that with saline. Due to distribution of the injected astaxanthin, PAI can image the margin of astaxanthin boles as well as quantify their volume in 3D reconstruction. Further investigations on selective tumor targeting are required to validate astaxanthin as a potential biocompatible contrast agent for PAI-assisted bladder cancer detection. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. The fabrication of novel nanobubble ultrasound contrast agent for potential tumor imaging

    NASA Astrophysics Data System (ADS)

    Xing, Zhanwen; Wang, Jinrui; Ke, Hengte; Zhao, Bo; Yue, Xiuli; Dai, Zhifei; Liu, Jibin

    2010-04-01

    Novel biocompatible nanobubbles were fabricated by ultrasonication of a mixture of Span 60 and polyoxyethylene 40 stearate (PEG40S) followed by differential centrifugation to isolate the relevant subpopulation from the parent suspensions. Particle sizing analysis and optical microscopy inspection indicated that the freshly generated micro/nanobubble suspension was polydisperse and the size distribution was bimodal with large amounts of nanobubbles. To develop a nano-sized contrast agent that is small enough to leak through tumor pores, a fractionation to extract smaller bubbles by variation in the time of centrifugation at 20g (relative centrifuge field, RCF) was suggested. The results showed that the population of nanobubbles with a precisely controlled mean diameter could be sorted from the initial polydisperse suspensions to meet the specified requirements. The isolated bubbles were stable over two weeks under the protection of perfluoropropane gas. The acoustic behavior of the nano-sized contrast agent was evaluated using power Doppler imaging in a normal rabbit model. An excellent power Doppler enhancement was found in vivo renal imaging after intravenous injection of the obtained nanobubbles. Given the broad spectrum of potential clinical applications, the nano-sized contrast agent may provide a versatile adjunct for ultrasonic imaging enhancement and/or treatment of tumors.

  6. Preparation and Evaluation of Multiple Nanoemulsions Containing Gadolinium (III) Chelate as a Potential Magnetic Resonance Imaging (MRI) Contrast Agent.

    PubMed

    Sigward, Estelle; Corvis, Yohann; Doan, Bich-Thuy; Kindsiko, Kadri; Seguin, Johanne; Scherman, Daniel; Brossard, Denis; Mignet, Nathalie; Espeau, Philippe; Crauste-Manciet, Sylvie

    2015-09-01

    The objective was to develop, characterize and assess the potentiality of W1/O/W2 self-emulsifying multiple nanoemulsions to enhance signal/noise ratio for Magnetic Resonance Imaging (MRI). For this purpose, a new formulation, was designed for encapsulation efficiency and stability. Various methods were used to characterize encapsulation efficiency ,in particular calorimetric methods (Differential Scanning Calorimetry (DSC), thermogravimetry analysis) and ultrafiltration. MRI in vitro relaxivities were assessed on loaded DTPA-Gd multiple nanoemulsions. Characterization of the formulation, in particular of encapsulation efficiency was a challenge due to interactions found with ultrafiltration method. Thanks to the specifically developed DSC protocol, we were able to confirm the formation of multiple nanoemulsions, differentiate loaded from unloaded nanoemulsions and measure the encapsulation efficiency which was found to be quite high with a 68% of drug loaded. Relaxivity studies showed that the self-emulsifying W/O/W nanoemulsions were positive contrast agents, exhibiting higher relaxivities than those of the DTPA-Gd solution taken as a reference. New self-emulsifying multiple nanoemulsions that were able to load satisfactory amounts of contrasting agent were successfully developed as potential MRI contrasting agents. A specific DSC protocol was needed to be developed to characterize these complex systems as it would be useful to develop these self-formation formulations.

  7. Stimuli-disassembling gold nanoclusters for diagnosis of early stage oral cancer by optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Kim, Chang Soo; Ingato, Dominique; Wilder-Smith, Petra; Chen, Zhongping; Kwon, Young Jik

    2018-01-01

    A key design consideration in developing contrast agents is obtaining distinct, multiple signal changes in diseased tissue. Plasmonic gold nanoparticles (Au NPs) have been developed as contrast agents due to their strong surface plasmon resonance (SPR). This study aims to demonstrate that stimuli-responsive plasmonic Au nanoclusters (Au NCs) can be used as a contrast agent for optical coherence tomography (OCT) in detecting early-stage cancer. Au NPs were clustered via acid-cleavable linkers to synthesize Au NCs that disassemble under mildly acidic conditions into individual Au NPs, simultaneously diminishing SPR effect (quantified by scattering intensity) and increasing Brownian motion (quantified by Doppler variance). The acid-triggered morphological and accompanying optico-physical property changes of the acid-disassembling Au NCs were confirmed by TEM, DLS, UV/Vis, and OCT. Stimuli-responsive Au NCs were applied in a hamster check pouch model carrying early-stage squamous carcinoma tissue. The tissue was visualized by OCT imaging, which showed reduced scattering intensity and increased Doppler variance in the dysplastic tissue. This study demonstrates the promise of diagnosing early-stage cancer using molecularly programmable, inorganic nanomaterial-based contrast agents that are capable of generating multiple, stimuli-triggered diagnostic signals in early-stage cancer.[Figure not available: see fulltext.

  8. Contrast Gradient-Based Blood Velocimetry With Computed Tomography: Theory, Simulations, and Proof of Principle in a Dynamic Flow Phantom.

    PubMed

    Korporaal, Johannes G; Benz, Matthias R; Schindera, Sebastian T; Flohr, Thomas G; Schmidt, Bernhard

    2016-01-01

    The aim of this study was to introduce a new theoretical framework describing the relationship between the blood velocity, computed tomography (CT) acquisition velocity, and iodine contrast enhancement in CT images, and give a proof of principle of contrast gradient-based blood velocimetry with CT. The time-averaged blood velocity (v(blood)) inside an artery along the axis of rotation (z axis) is described as the mathematical division of a temporal (Hounsfield unit/second) and spatial (Hounsfield unit/centimeter) iodine contrast gradient. From this new theoretical framework, multiple strategies for calculating the time-averaged blood velocity from existing clinical CT scan protocols are derived, and contrast gradient-based blood velocimetry was introduced as a new method that can calculate v(blood) directly from contrast agent gradients and the changes therein. Exemplarily, the behavior of this new method was simulated for image acquisition with an adaptive 4-dimensional spiral mode consisting of repeated spiral acquisitions with alternating scan direction. In a dynamic flow phantom with flow velocities between 5.1 and 21.2 cm/s, the same acquisition mode was used to validate the simulations and give a proof of principle of contrast gradient-based blood velocimetry in a straight cylinder of 2.5 cm diameter, representing the aorta. In general, scanning with the direction of blood flow results in decreased and scanning against the flow in increased temporal contrast agent gradients. Velocity quantification becomes better for low blood and high acquisition speeds because the deviation of the measured contrast agent gradient from the temporal gradient will increase. In the dynamic flow phantom, a modulation of the enhancement curve, and thus alternation of the contrast agent gradients, can be observed for the adaptive 4-dimensional spiral mode and is in agreement with the simulations. The measured flow velocities in the downslopes of the enhancement curves were in good agreement with the expected values, although the accuracy and precision worsened with increasing flow velocities. The new theoretical framework increases the understanding of the relationship between the blood velocity, CT acquisition velocity, and iodine contrast enhancement in CT images, and it interconnects existing blood velocimetry methods with research on transluminary attenuation gradients. With these new insights, novel strategies for CT blood velocimetry, such as the contrast gradient-based method presented in this article, may be developed.

  9. The Effects of Image and Animation in Enhancing Pedagogical Agent Persona

    ERIC Educational Resources Information Center

    Baylor, Amy L.; Ryu, Jeeheon

    2003-01-01

    The purpose of this experimental study was to test the role of image and animation on: a) learners' perceptions of pedagogical agent persona characteristics (i.e., extent to which agent was person-like, engaging, credible, and instructor-like); b) agent value; and c) performance. The primary analysis consisted of two contrast comparisons: 1)…

  10. Tunable, biodegradable gold nanoparticles as contrast agents for computed tomography and photoacoustic imaging

    PubMed Central

    Cheheltani, Rabee; Ezzibdeh, Rami M.; Chhour, Peter; Pulaparthi, Kumidini; Kim, Johoon; Jurcova, Martina; Hsu, Jessica C.; Blundell, Cassidy; Litt, Harold I.; Ferrari, Victor A.; Allcock, Harry R.; Sehgal, Chandra M.; Cormode, David P.

    2016-01-01

    Gold nanoparticles (AuNP) have been proposed for many applications in medicine. Although large AuNP (>5.5 nm) are desirable for their longer blood circulation and accumulation in diseased tissues, small AuNP (<5.5 nm) are required for excretion via the kidneys. We present a novel platform where small, excretable AuNP are encapsulated into biodegradable poly di(carboxylatophenoxy)phosphazene (PCPP) nanospheres. These larger nanoparticles (Au-PCPP) can perform their function as contrast agents, then subsequently break down into harmless byproducts and release the AuNP for swift excretion. Homogeneous Au-PCPP were synthesized using a microfluidic device. The size of the Au-PCPP can be controlled by the amount of polyethylene glycol-polylysine (PEG-PLL) block co-polymer in the formulation. Synthesis of Au-PCPP nanoparticles and encapsulation of AuNP in PCPP were evaluated using transmission electron microscopy and their biocompatibility and biodegradability confirmed in vitro. The Au-PCPP nanoparticles were found to produce strong computed tomography contrast. The UV-Vis absorption peak of Au-PCPP can be tuned into the near infrared region via inclusion of varying amounts of AuNP and controlling the nanoparticle size. In vitro and in vivo experiments demonstrated the potential of Au-PCPP as contrast agents for photoacoustic imaging. Therefore, Au-PCPP nanoparticles have high potency as contrast agents for two imaging modalities, as well as being biocompatible and biodegradable, and thus represent a platform with potential for translation into the clinic. PMID:27322961

  11. Properties of iopamidol-incorporated poly(vinyl alcohol) microparticle as an X-ray imaging flow tracer.

    PubMed

    Ahn, Sungsook; Jung, Sung Yong; Lee, Jin Pyung; Lee, Sang Joon

    2011-02-10

    We have recently reported on poly(vinyl alcohol) microparticles containing X-ray contrast agent, iopamidol, designed as a flow tracer working in synchrotron X-ray imaging ( Biosens. Bioelectron. 2010 , 25 , 1571 ). Although iopamidol is physically encapsulated in the microparticles, it displays a great contrast enhancement and stable feasibility in in vitro human blood pool. Nonetheless, a direct relation between the absolute amount of incorporated iopamidol and the enhancement in imaging efficiency was not observed. In this study, physical properties of the designed microparticle are systematically investigated experimentally with theoretical interpretation to correlate an enhancement in X-ray imaging efficiency. The compositional ratio of X-ray contrast agent in polymeric microparticle is controlled as 1/1 and 10/1 [contrast agent/polymer microparticle (w/w)] with changed degree of cross-linkings. Flory-Huggins interaction parameter (χ), retractive force (τ) and degree of swelling of the designed polymeric microparticles are investigated. In addition, the hydrodynamic size (D(H)) and ζ-potential are evaluated in terms of environment responsiveness. The physical properties of the designed flow tracer microparticles under a given condition are observed to be strongly related with the X-ray absorption efficiency, which are also supported by the Beer-Lambert-Bouguer law. The designed microparticles are almost nontoxic with a reasonable concentration and time period, enough to be utilized as a flow tracer in various biomedical applications. This study would contribute to the basic understanding on the physical property connected with the imaging efficiency of contrast agents.

  12. A polymeric micelle magnetic resonance imaging (MRI) contrast agent reveals blood-brain barrier (BBB) permeability for macromolecules in cerebral ischemia-reperfusion injury.

    PubMed

    Shiraishi, Kouichi; Wang, Zuojun; Kokuryo, Daisuke; Aoki, Ichio; Yokoyama, Masayuki

    2017-05-10

    Blood-brain barrier (BBB) opening is a key phenomenon for understanding ischemia-reperfusion injuries that are directly linked to hemorrhagic transformation. The recombinant human tissue-type plasminogen activator (rtPA) increases the risk of symptomatic intracranial hemorrhages. Recent imaging technologies have advanced our understanding of pathological BBB disorders; however, an ongoing challenge in the pre-"rtPA treatment" stage is the task of developing a rigorous method for hemorrhage-risk assessments. Therefore, we examined a novel method for assessment of rtPA-extravasation through a hyper-permeable BBB. To examine the image diagnosis of rtPA-extravasation for a rat transient occlusion-reperfusion model, in this study we used a polymeric micelle MRI contrast-agent (Gd-micelles). Specifically, we used two MRI contrast agents at 1h after reperfusion. Gd-micelles provided very clear contrast images in 15.5±10.3% of the ischemic hemisphere at 30min after i.v. injection, whereas a classic gadolinium chelate MRI contrast agent provided no satisfactorily clear images. The obtained images indicate both the hyper-permeable BBB area for macromolecules and the distribution area of macromolecules in the ischemic hemisphere. Owing to their large molecular weight, Gd-micelles remained in the ischemic hemisphere through the hyper-permeable BBB. Our results indicate the feasibility of a novel clinical diagnosis for evaluating rtPA-related hemorrhage risks. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Non-immunogenic dextran-coated superparamagnetic iron oxide nanoparticles: a biocompatible, size-tunable contrast agent for magnetic resonance imaging.

    PubMed

    Unterweger, Harald; Janko, Christina; Schwarz, Marc; Dézsi, László; Urbanics, Rudolf; Matuszak, Jasmin; Őrfi, Erik; Fülöp, Tamás; Bäuerle, Tobias; Szebeni, János; Journé, Clément; Boccaccini, Aldo R; Alexiou, Christoph; Lyer, Stefan; Cicha, Iwona

    2017-01-01

    Iron oxide-based contrast agents have been in clinical use for magnetic resonance imaging (MRI) of lymph nodes, liver, intestines, and the cardiovascular system. Superparamagnetic iron oxide nanoparticles (SPIONs) have high potential as a contrast agent for MRI, but no intravenous iron oxide-containing agents are currently approved for clinical imaging. The aim of our work was to analyze the hemocompatibility and immuno-safety of a new type of dextran-coated SPIONs (SPIONdex) and to characterize these nanoparticles with ultra-high-field MRI. Key parameters related to nanoparticle hemocompatibility and immuno-safety were investigated in vitro and ex vivo. To address concerns associated with hypersensitivity reactions to injectable nanoparticulate agents, we analyzed complement activation-related pseudoallergy (CARPA) upon intravenous administration of SPIONdex in a pig model. Furthermore, the size-tunability of SPIONdex and the effects of size reduction on their biocompatibility were investigated. In vitro, SPIONdex did not induce hemolysis, complement or platelet activation, plasma coagulation, or leukocyte procoagulant activity, and had no relevant effect on endothelial cell viability or endothelial-monocytic cell interactions. Furthermore, SPIONdex did not induce CARPA even upon intravenous administration of 5 mg Fe/kg in pigs. Upon SPIONdex administration in mice, decreased liver signal intensity was observed after 15 minutes and was still detectable 24 h later. In addition, by changing synthesis parameters, a reduction in particle size <30 nm was achieved, without affecting their hemo- and biocompatibility. Our findings suggest that due to their excellent biocompatibility, safety upon intravenous administration and size-tunability, SPIONdex particles may represent a suitable candidate for a new-generation MRI contrast agent.

  14. Analysis of DIRAC's behavior using model checking with process algebra

    NASA Astrophysics Data System (ADS)

    Remenska, Daniela; Templon, Jeff; Willemse, Tim; Bal, Henri; Verstoep, Kees; Fokkink, Wan; Charpentier, Philippe; Graciani Diaz, Ricardo; Lanciotti, Elisa; Roiser, Stefan; Ciba, Krzysztof

    2012-12-01

    DIRAC is the grid solution developed to support LHCb production activities as well as user data analysis. It consists of distributed services and agents delivering the workload to the grid resources. Services maintain database back-ends to store dynamic state information of entities such as jobs, queues, staging requests, etc. Agents use polling to check and possibly react to changes in the system state. Each agent's logic is relatively simple; the main complexity lies in their cooperation. Agents run concurrently, and collaborate using the databases as shared memory. The databases can be accessed directly by the agents if running locally or through a DIRAC service interface if necessary. This shared-memory model causes entities to occasionally get into inconsistent states. Tracing and fixing such problems becomes formidable due to the inherent parallelism present. We propose more rigorous methods to cope with this. Model checking is one such technique for analysis of an abstract model of a system. Unlike conventional testing, it allows full control over the parallel processes execution, and supports exhaustive state-space exploration. We used the mCRL2 language and toolset to model the behavior of two related DIRAC subsystems: the workload and storage management system. Based on process algebra, mCRL2 allows defining custom data types as well as functions over these. This makes it suitable for modeling the data manipulations made by DIRAC's agents. By visualizing the state space and replaying scenarios with the toolkit's simulator, we have detected race-conditions and deadlocks in these systems, which, in several cases, were confirmed to occur in the reality. Several properties of interest were formulated and verified with the tool. Our future direction is automating the translation from DIRAC to a formal model.

  15. Acoustic fingerprints of dye-labeled protein submicrosphere photoacoustic contrast agents

    NASA Astrophysics Data System (ADS)

    McDonald, Michael A.; Jankovic, Ladislav; Shahzad, Khalid; Burcher, Michael; Li, King C. P.

    2009-05-01

    Dye-labeled protein microspheres, submicron in size and capable of producing thermoelastically generated ultrasound in response to laser stimulation, are presented as contrast agents for photoacoustic imaging. Incident laser energy absorbed by fluorescein isothiocyanate (FITC)-labeled elastin submicrospheres results in thermoelastically generated sound production. Plotted A-line graphs reveal a distinctive morphology and a greater than two orders of magnitude increase in signal amplitude subsequent to converting FITC elastin into submicrospheres (despite a four orders of magnitude decrease in concentration). Evidence of nonlinearity and enhancement of ultrasound backscatter indicate a potential use in contrast-enhanced harmonic imaging. Photoacoustic and ultrasound imaging of FITC-elastin submicrospheres in a water-filled phantom vessel shows enhanced contrast at low concentration and clear delineation of the phantom vessel wall.

  16. Descriptive analysis and comparison of two French occupational exposure databases: COLCHIC and SCOLA.

    PubMed

    Mater, Gautier; Paris, Christophe; Lavoué, Jérôme

    2016-05-01

    Several countries have built databases of occupational hygiene measurements. In France, COLCHIC and SCOLA co-exist, started in 1987 and 2007, respectively. A descriptive comparison of the content of the two databases was carried out during the period 1987-2012, including variables, workplaces and agents, as well as exposure levels. COLCHIC and SCOLA contain, respectively, 841,682 (670 chemicals) and 152,486 records (70). They cover similar industries and occupations, and contain the same ancillary information. Across 17 common agents with >500 samples, the ratio of the median concentration in COLCHIC to the median concentration in SCOLA was 3.45 [1.03-14.3] during 2007-2012. This pattern remained when stratified by industry, task, and occupation, but was attenuated when restricted to similar sampling duration. COLCHIC and SCOLA represent a considerable source of information, but result from different purposes (prevention, regulatory). Potential differences due to strategies should evaluated when interpreting data from these databases. © 2016 Wiley Periodicals, Inc.

  17. Target-specific contrast agents for magnetic resonance microscopy

    PubMed Central

    Blackwell, Megan L.; Farrar, Christian T.; Fischl, Bruce; Rosen, Bruce R.

    2009-01-01

    High-resolution ex vivo magnetic resonance (MR) imaging can be used to delineate prominent architectonic features in the human brain, but increased contrast is required to visualize more subtle distinctions. To aid MR sensitivity to cell density and myelination, we have begun the development of target-specific paramagnetic contrast agents. This work details the first application of luxol fast blue (LFB), an optical stain for myelin, as a white matter-selective MR contrast agent for human ex vivo brain tissue. Formalin-fixed human visual cortex was imaged with an isotropic resolution between 80 and 150 μm at 4.7 and 14 T before and after en bloc staining with LFB. Longitudinal (R1) and transverse (R2) relaxation rates in LFB-stained tissue increased proportionally with myelination at both field strengths. Changes in R1 resulted in larger contrast-to-noise ratios (CNR), per unit time, on T1-weighted images between more myelinated cortical layers (IV–VI) and adjacent, superficial layers (I–III) at both field strengths. Specifically, CNR for LFB-treated samples increased by 229±13% at 4.7 T and 269±25% at 14 T when compared to controls. Also, additional cortical layers (IVca, IVd, and Va) were resolvable in 14T-MR images of LFB-treated samples but not in control samples. After imaging, samples were sliced in 40-micron sections, mounted, and photographed. Both the macroscopic and microscopic distributions of LFB were found to mimic those of traditional histological preparations. Our results suggest target-specific contrast agents will enable more detailed MR images with applications in imaging pathological ex vivo samples and constructing better MR atlases from ex vivo brains. PMID:19385012

  18. Diffusion of ionic and non-ionic contrast agents in articular cartilage with increased cross-linking--contribution of steric and electrostatic effects.

    PubMed

    Kulmala, K A M; Karjalainen, H M; Kokkonen, H T; Tiitu, V; Kovanen, V; Lammi, M J; Jurvelin, J S; Korhonen, R K; Töyräs, J

    2013-10-01

    To investigate the effect of threose-induced collagen cross-linking on diffusion of ionic and non-ionic contrast agents in articular cartilage. Osteochondral plugs (Ø=6mm) were prepared from bovine patellae and divided into two groups according to the contrast agent to be used in contrast enhanced computed tomography (CECT) imaging: (I) anionic ioxaglate and (II) non-ionic iodixanol. The groups I and II contained 7 and 6 sample pairs, respectively. One of the paired samples served as a reference while the other was treated with threose to induce collagen cross-linking. The equilibrium partitioning of the contrast agents was imaged after 24h of immersion. Fixed charge density (FCD), water content, contents of proteoglycans, total collagen, hydroxylysyl pyridinoline (HP), lysyl pyridinoline (LP) and pentosidine (Pent) cross-links were determined as a reference. The equilibrium partitioning of ioxaglate (group I) was significantly (p=0.018) lower (-23.4%) in threose-treated than control samples while the equilibrium partitioning of iodixanol (group II) was unaffected by the threose-treatment. FCD in the middle and deep zones of the cartilage (p<0.05) and contents of Pent and LP (p=0.001) increased significantly due to the treatment. However, the proteoglycan concentration was not systematically altered after the treatment. Water content was significantly (-3.5%, p=0.007) lower after the treatment. Since non-ionic iodixanol showed no changes in partition after cross-linking, in contrast to anionic ioxaglate, we conclude that the cross-linking induced changes in charge distribution have greater effect on diffusion compared to the cross-linking induced changes in steric hindrance. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

  19. Lipid-based nanoparticles for contrast-enhanced MRI and molecular imaging.

    PubMed

    Mulder, Willem J M; Strijkers, Gustav J; van Tilborg, Geralda A F; Griffioen, Arjan W; Nicolay, Klaas

    2006-02-01

    In the field of MR imaging and especially in the emerging field of cellular and molecular MR imaging, flexible strategies to synthesize contrast agents that can be manipulated in terms of size and composition and that can be easily conjugated with targeting ligands are required. Furthermore, the relaxivity of the contrast agents, especially for molecular imaging applications, should be very high to deal with the low sensitivity of MRI. Lipid-based nanoparticles, such as liposomes or micelles, have been used extensively in recent decades as drug carrier vehicles. A relatively new and promising application of lipidic nanoparticles is their use as multimodal MR contrast agents. Lipids are amphiphilic molecules with both a hydrophobic and a hydrophilic part, which spontaneously assemble into aggregates in an aqueous environment. In these aggregates, the amphiphiles are arranged such that the hydrophobic parts cluster together and the hydrophilic parts face the water. In the low concentration regime, a wide variety of structures can be formed, ranging from spherical micelles to disks or liposomes. Furthermore, a monolayer of lipids can serve as a shell to enclose a hydrophobic core. Hydrophobic iron oxide particles, quantum dots or perfluorocarbon emulsions can be solubilized using this approach. MR-detectable and fluorescent amphiphilic molecules can easily be incorporated in lipidic nanoparticles. Furthermore, targeting ligands can be conjugated to lipidic particles by incorporating lipids with a functional moiety to allow a specific interaction with molecular markers and to achieve accumulation of the particles at disease sites. In this review, an overview of different lipidic nanoparticles for use in MRI is given, with the main emphasis on Gd-based contrast agents. The mechanisms of particle formation, conjugation strategies and applications in the field of contrast-enhanced, cellular and molecular MRI are discussed. 2006 John Wiley & Sons, Ltd.

  20. Magnetic resonance imaging of osteosarcoma using a bis(alendronate)-based bone-targeted contrast agent.

    PubMed

    Ge, Pingju; Sheng, Fugeng; Jin, Yiguang; Tong, Li; Du, Lina; Zhang, Lei; Tian, Ning; Li, Gongjie

    2016-12-01

    Magnetic resonance (MR) is currently used for diagnosis of osteosarcoma but not well even though contrast agents are administered. Here, we report a novel bone-targeted MR imaging contrast agent, Gd 2 -diethylenetriaminepentaacetate-bis(alendronate) (Gd 2 -DTPA-BA) for the diagnosis of osteosarcoma. It is the conjugate of a bone cell-seeking molecule (i.e., alendronate) and an MR imaging contrast agent (i.e., Gd-DTPA). Its physicochemical parameters were measured, including pK a , complex constant, and T 1 relaxivity. Its bone cell-seeking ability was evaluated by measuring its adsorption on hydroxyapatite. Hemolysis was investigated. MR imaging and biodistribution of Gd 2 -DTPA-BA and Gd-DTPA were studied on healthy and osteosarcoma-bearing nude mice. Gd 2 -DTPA-BA showed high adsorption on hydroxyapatite, the high MR relaxivity (r 1 ) of 7.613mM -1 s -1 (2.6 folds of Gd-DTPA), and no hemolysis. The MR contrast effect of Gd 2 -DTPA-BA was much higher than that of Gd-DTPA after intravenous injection to the mice. More importantly, the MR imaging of osteosarcoma was significantly improved by Gd 2 -DTPA-BA. The signal intensity of Gd 2 -DTPA-BA reached 120.3% at 50min, equal to three folds of Gd-DTPA. The bone targeting index (bone/blood) of Gd 2 -DTPA-BA in the osteosarcoma-bearing mice was very high to 130 at 180min. Furthermore, the contrast enhancement could also be found in the lung due to metastasis of osteosarcoma. Gd 2 -DTPA-BA plays a promising role in the diagnoses of osteosacomas, including the primary bone tumors and metastases. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  1. Feasibility of dual-low scheme combined with iterative reconstruction technique in acute cerebral infarction volume CT whole brain perfusion imaging.

    PubMed

    Wang, Tao; Gong, Yi; Shi, Yibing; Hua, Rong; Zhang, Qingshan

    2017-07-01

    The feasibility of application of low-concentration contrast agent and low tube voltage combined with iterative reconstruction in whole brain computed tomography perfusion (CTP) imaging of patients with acute cerebral infarction was investigated. Fifty-nine patients who underwent whole brain CTP examination and diagnosed with acute cerebral infarction from September 2014 to March 2016 were selected. Patients were randomly divided into groups A and B. There were 28 cases in group A [tube voltage, 100 kV; contrast agent, iohexol (350 mg I/ml), reconstructed by filtered back projection] and 31 cases in group B [tube voltage, 80 kV; contrast agent, iodixanol (270 mg I/ml), reconstructed by algebraic reconstruction technique]. The artery CT value, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), dose length product, effective dose (ED) of radiation and brain iodine intake of both groups were measured and statistically analyzed. Two physicians carried out kappa (κ) analysis on the consistency of image quality evaluation. The difference in subjective image quality evaluation between the groups was tested by χ 2 . The differences in CT value, SNR, CNR, CTP and CT angiography subjective image quality evaluation between both groups were not statistically significant (P>0.05); the diagnosis rate of the acute infarcts between the two groups was not significantly different; while the ED and iodine intake in group B (dual low-dose group) were lower than group A. In conclusion, combination of low tube voltage and iterative reconstruction technique, and application of low-concentration contrast agent (270 mg I/ml) in whole brain CTP examination reduced ED and iodine intake without compromising image quality, thereby reducing the risk of contrast-induced nephropathy.

  2. Superparamagnetic iron oxide nanoparticles for MRI: contrast media pharmaceutical company R&D perspective.

    PubMed

    Corot, Claire; Warlin, David

    2013-01-01

    Superparamagnetic iron oxide (SPIO) nanoparticles are a relatively large class of contrast agents for magnetic resonance imaging. According to their biodistribution, distinct classes of SPIO nanoparticles have been investigated for clinical applications either as macrophage imaging agents or blood pool agents. Contrast agents which are pharmaceutics followed the same development rules as therapeutic drugs. Several drawbacks such as clinical development difficulties, organization of market access and imaging technological developments have limited the widespread use of these products. SPIO nanoparticles that are composed of thousands iron atoms providing large T2* effects are particularly suitable for theranostic. Stem cell migration and immune cell trafficking, as well as targeted SPIO nanoparticles for molecular imaging studies are mainly at the stage of proof of concept. A major economic challenge in the development of molecular imaging associated with a therapeutic treatment/procedure is to define innovative business models compatible with the needs of all players taking into account that theranostic solutions are promising to optimize resource allocation and ensure that expensive treatments are prescribed to responding patients. © 2013 Wiley Periodicals, Inc.

  3. True happiness: The role of morality in the folk concept of happiness.

    PubMed

    Phillips, Jonathan; De Freitas, Julian; Mott, Christian; Gruber, June; Knobe, Joshua

    2017-02-01

    Recent scientific research has settled on a purely descriptive definition of happiness that is focused solely on agents' psychological states (high positive affect, low negative affect, high life satisfaction). In contrast to this understanding, recent research has suggested that the ordinary concept of happiness is also sensitive to the moral value of agents' lives. Five studies systematically investigate and explain the impact of morality on ordinary assessments of happiness. Study 1 demonstrates that moral judgments influence assessments of happiness not only for untrained participants, but also for academic researchers and even in those who study happiness specifically. Studies 2 and 3 then respectively ask whether this effect may be explained by general motivational biases or beliefs in a just world. In both cases, we find evidence against these explanations. Study 4 shows that the impact of moral judgments cannot be explained by changes in the perception of descriptive psychological states. Finally, Study 5 compares the impact of moral and nonmoral value, and provides evidence that unlike nonmoral value, moral value is part of the criteria that govern the ordinary concept of happiness. Taken together, these studies provide a specific explanation of how and why the ordinary concept of happiness deviates from the definition used by researchers studying happiness. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  4. Gd-complexes of macrocyclic DTPA conjugates of 1,1'-bis(amino)ferrocenes as high relaxivity MRI blood-pool contrast agents (BPCAs).

    PubMed

    Kim, Hee-Kyung; Park, Ji-Ae; Kim, Kyeong Min; Nasiruzzaman, Sk Md; Kang, Duk-Sik; Lee, Jongmin; Chang, Yongmin; Kim, Tae-Jeong

    2010-11-28

    We report the synthesis of macrocyclic DTPA conjugates of 1,1'-bis(amino)ferrocenes (1a-b) and their Gd-complexes [Gd(L)(H(2)O)] (2a-b, L = 1a-b) for use as new MRI blood-pool contrast agents. High R(1) relaxivity in HSA as well as high thermodynamic and kinetic stabilities is observed for 2a.

  5. Theoretical analysis of chirp excitation of contrast agents

    NASA Astrophysics Data System (ADS)

    Barlow, Euan; Mulholland, Anthony J.; Nordon, Alison; Gachagan, Anthony

    2010-01-01

    Analytic expressions are found for the amplitude of the first and second harmonics of the Ultrasound Contrast Agent's (UCA's) dynamics when excited by a chirp. The dependency of the second harmonic amplitude on the system parameters, the UCA shell parameters, and the insonifying signal parameters is then investigated. It is shown that optimal parameter values exist which give rise to a clear increase in the second harmonic component of the UCA's motion.

  6. Experimental Study of Ultrasound Contrast Agent Mediated Heat Transfer for Therapeutic Applications

    NASA Astrophysics Data System (ADS)

    Razansky, D.; Adam, D. R.; Einziger, P. D.

    2006-05-01

    Ultrasound Contrast Agents (UCA) have been recently suggested as efficient enhancers of ultrasonic power deposition in tissue. The ultrasonic energy absorption by UCA, considered as disadvantageous in diagnostic imaging, might be valuable in therapeutic applications such as targeted hyperthermia or ablation treatments. The current study, based on theoretical predictions, was designed to experimentally measure the dissipation and heating effects of encapsulated UCA (Optison™) in a well-controlled and calibrated environment.

  7. Preclinical animal acute toxicity studies of new developed MRI contrast agent based on gadolinium

    NASA Astrophysics Data System (ADS)

    Nam, I. F.; Zhuk, V. V.

    2015-04-01

    Acute toxicity test of new developed MRI contrast agent based on disodium salt of gadopentetic acid complex were carried out on Mus musculus and Sprague Dawley rats according to guidelines of preclinical studies [1]. Groups of six animals each were selected for experiment. Death and clinical symptoms of animals were recorded during 14 days. As a result the maximum tolerated dose (MTD) for female mice is 2.8 mM/kg of body weight, male mice - 1.4 mM/kg, female rats - 2.8 mM/kg, male rats - 5.6 mM/kg of body weight. No Observed Adverse Effect Dose (NOAEL) for female mice is 1.4 mM/kg, male mice - 0.7 mM/kg, male and female rats - 0.7 mM/kg. According to experimental data new developed MRI contrast agent based on Gd-DTPA complex is low-toxic.

  8. Acoustic cavitation of individual ultrasound contrast agent microbubbles confined in capillaries

    NASA Astrophysics Data System (ADS)

    Almaqwashi, Ali; McIntyre, David; Ammi, Azzdine

    2011-10-01

    Ultrasound targeted therapies mainly rely on the inertial cavitation of ultrasound contrast agent (UCA) microbubbles. Our objective is to determine the cavitation acoustic pressure threshold for the destruction of UCA microbubbles inside cellulose capillaries. Acoustic emission from individual Optison microbubbles confined inside a 200-μm diameter capillary was detected using a passive cavitation detection system. Excitation signals from a 2.25 MHz transmitter were applied to the microbubbles while their acoustic emission was detected by a broadband 15 MHz receiver. Time traces were recorded (100 MHz sampling, 12- bit), and frequency-domain analysis of the received signals was performed to characterize microbubble cavitation. The cavitation acoustic pressure threshold was found to be 1 MPa inside the capillary in comparison with ˜0.7 MPa previously reported for unconfined UCA microbubbles. This work provides a clearer understanding of the role of ultrasound contrast agent dynamics inside a capillary.

  9. A common-path optical coherence tomography based electrode for structural imaging of nerves and recording of action potentials

    NASA Astrophysics Data System (ADS)

    Islam, M. Shahidul; Haque, Md. Rezuanul; Oh, Christian M.; Wang, Yan; Park, B. Hyle

    2013-03-01

    Current technologies for monitoring neural activity either use different variety of electrodes (electrical recording) or require contrast agents introduced exogenously or through genetic modification (optical imaging). Here we demonstrate an optical method for non-contact and contrast agent free detection of nerve activity using phase-resolved optical coherence tomography (pr-OCT). A common-path variation of the pr-OCT is recently implemented and the developed system demonstrated the capability to detect rapid transient structural changes that accompany neural spike propagation. No averaging over multiple trials was required, indicating its capability of single-shot detection of individual impulses from functionally stimulated Limulus optic nerve. The strength of this OCT-based optical electrode is that it is a contactless method and does not require any exogenous contrast agent. With further improvements in accuracy and sensitivity, this optical electrode will play a complementary role to the existing recording technologies in future.

  10. Synthesis and characterization of superparamagnetic iron-oxide nanoparticles (SPIONs) and utilization of SPIONs in X-ray imaging

    NASA Astrophysics Data System (ADS)

    Justin, C.; Philip, Sheryl Ann; Samrot, Antony V.

    2017-10-01

    The versatility of superparamagnetic iron-oxide nanoparticles (SPIONs) have been extensively investigated, especially for their applications in therapeutics and diagnostics. Considering their intriguing feature of contrasting agent, in terms of medical applications, it is still in its infancy. Various physicochemical parameters like magnetism, crystallinity, and optical parameters contribute to their better contrasting agent. In this study, SPIONs were synthesized with different concentrations of precursor iron molecular solution in the presence of magnetic field and the optimum concentration of precursor iron molecular solution was determined as 0.133%. SPIONs obtained at optimum concentration were further analyzed by both microscopic and spectroscopic analysis. The difference occurred in the elemental nature of SPIONs as they were synthesized in the magnetic field out of precursor iron molecular solution was analyzed with a specific reference to NMR spectroscopy. SPIONs as contrasting agent against X-ray imaging was also investigated in quail's egg.

  11. Gold nanoparticles for photoacoustic imaging

    PubMed Central

    Li, Wanwan; Chen, Xiaoyuan

    2015-01-01

    Photoacoustic (PA) imaging is a biomedical imaging modality that provides functional information regarding the cellular and molecular signatures of tissue by using endogenous and exogenous contrast agents. There has been tremendous effort devoted to the development of PA imaging agents, and gold nanoparticles as exogenous contrast agents have great potential for PA imaging due to their inherent and geometrically induced optical properties. The gold-based nanoparticles that are most commonly employed for PA imaging include spheres, rods, shells, prisms, cages, stars and vesicles. This article provides an overview of the current state of research in utilizing these gold nanomaterials for PA imaging of cancer, atherosclerotic plaques, brain function and image-guided therapy. PMID:25600972

  12. A simple polyol-free synthesis route to Gd2O3 nanoparticles for MRI applications: an experimental and theoretical study

    NASA Astrophysics Data System (ADS)

    Ahrén, Maria; Selegård, Linnéa; Söderlind, Fredrik; Linares, Mathieu; Kauczor, Joanna; Norman, Patrick; Käll, Per-Olov; Uvdal, Kajsa

    2012-08-01

    Chelated gadolinium ions, e.g., Gd-DTPA, are today used clinically as contrast agents for magnetic resonance imaging (MRI). An attractive alternative contrast agent is composed of gadolinium oxide nanoparticles as they have shown to provide enhanced contrast and, in principle, more straightforward molecular capping possibilities. In this study, we report a new, simple, and polyol-free way of synthesizing 4-5-nm-sized Gd2O3 nanoparticles at room temperature, with high stability and water solubility. The nanoparticles induce high-proton relaxivity compared to Gd-DTPA showing r 1 and r 2 values almost as high as those for free Gd3+ ions in water. The Gd2O3 nanoparticles are capped with acetate and carbonate groups, as shown with infrared spectroscopy, near-edge X-ray absorption spectroscopy, X-ray photoelectron spectroscopy and combined thermogravimetric and mass spectroscopy analysis. Interpretation of infrared spectroscopy data is corroborated by extensive quantum chemical calculations. This nanomaterial is easily prepared and has promising properties to function as a core in a future contrast agent for MRI.

  13. Preclinical validation of the utility of BLZ-100 in providing fluorescence contrast for imaging canine spontaneous solid tumors

    PubMed Central

    Fidel, Janean; Kennedy, Katie C.; Dernell, William S.; Hansen, Stacey; Wiss, Valorie; Stroud, Mark R.; Molho, Joshua I.; Knoblaugh, Sue E.; Meganck, Jeffrey; Olson, James M.; Rice, Brad; Parrish-Novak, Julia

    2015-01-01

    There is a need in surgical oncology for contrast agents that can enable real-time intraoperative visualization of solid tumors that can enable complete resections while sparing normal surrounding tissues. The Tumor Paint™ agent BLZ-100 is a peptide-fluorophore conjugate that can specifically bind solid tumors and fluoresce in the near-infrared range, minimizing light scatter and signal attenuation. In this study, we provide a preclinical proof of concept for use of this imaging contrast agent as administered before surgery to dogs with a variety of naturally occurring spontaneous tumors. Imaging was performed on excised tissues as well as intraoperatively in a subset of cases. Actionable contrast was achieved between tumor tissue and surrounding normal tissues in adenocarcinomas, squamous cell carcinomas, mast cell tumors and soft tissue sarcomas. Subcutaneous soft tissue sarcomas were labeled with the highest fluorescence intensity and greatest tumor-to-background signal ratio. Our results establish a foundation that rationalizes clinical studies in humans with soft tissue sarcoma, an indication with a notably high unmet need. PMID:26471914

  14. Study of Tissue Phantoms, Tissues, and Contrast Agent with the Biophotoacoustic Radar and Comparison to Ultrasound Imaging for Deep Subsurface Imaging

    NASA Astrophysics Data System (ADS)

    Alwi, R.; Telenkov, S.; Mandelis, A.; Gu, F.

    2012-11-01

    In this study, the imaging capability of our wide-spectrum frequency-domain photoacoustic (FD-PA) imaging alias "photoacoustic radar" methodology for imaging of soft tissues is explored. A practical application of the mathematical correlation processing method with relatively long (1 ms) frequency-modulated optical excitation is demonstrated for reconstruction of the spatial location of the PA sources. Image comparison with ultrasound (US) modality was investigated to see the complementarity between the two techniques. The obtained results with a phased array probe on tissue phantoms and their comparison to US images demonstrated that the FD-PA technique has strong potential for deep subsurface imaging with excellent contrast and high signal-to-noise ratio. FD-PA images of blood vessels in a human wrist and an in vivo subcutaneous tumor in a rat model are presented. As in other imaging modalities, the employment of contrast agents is desirable to improve the capability of medical diagnostics. Therefore, this study also evaluated and characterized the use of Food and Drug Administration (FDA)-approved superparamagnetic iron oxide nanoparticles (SPION) as PA contrast agents.

  15. Non-invasive imaging of barriers to drug delivery in tumors.

    PubMed

    Hassid, Yaron; Eyal, Erez; Margalit, Raanan; Furman-Haran, Edna; Degani, Hadassa

    2008-08-01

    Solid tumors often develop high interstitial fluid pressure (IFP) as a result of increased water leakage and impaired lymphatic drainage, as well as changes in the extracellular matrix composition and elasticity. This high fluid pressure forms a barrier to drug delivery and hence, resistance to therapy. We have developed techniques based on contrast enhanced magnetic resonance imaging for mapping in tumors the vascular and transport parameters determining the delivery efficiency of blood borne substances. Sequential images are recorded during continuous infusion of a Gd-based contrast agent and analyzed according to a new physiological model, yielding maps of microvascular transfer constants, as well as outward convective interstitial transfer constants and steady state interstitial contrast agent concentrations both reflecting IFP distribution. We further demonstrated in non small cell human lung cancer xenografts the capability of our techniques to monitor in vivo collagenase induced increase in contrast agent delivery as a result of decreased IFP. These techniques can be applied to test drugs that affect angiogenesis and modulate interstitial fluid pressure and has the potential to be extended to cancer patients for assessing resistance to drug delivery.

  16. Non-Invasive Imaging of Barriers to Drug Delivery in Tumors

    PubMed Central

    Hassid, Yaron; Eyal, Erez; Margalit, Raanan; Furman-Haran, Edna; Degani, Hadassa

    2011-01-01

    Solid tumors often develop high interstitial fluid pressure (IFP) as a result of increased water leakage and impaired lymphatic drainage, as well as changes in the extracellular matrix composition and elasticity. This high fluid pressure forms a barrier to drug delivery and hence, resistance to therapy. We have developed techniques based on contrast enhanced magnetic resonance imaging for mapping in tumors the vascular and transport parameters determining the delivery efficiency of blood borne substances. Sequential images are recorded during continuous infusion of a Gd-based contrast agent and analyzed according to a new physiological model, yielding maps of microvascular transfer constants, as well as outward convective interstitial transfer constants and steady state interstitial contrast agent concentrations both reflecting IFP distribution. We further demonstrated in non small cell human lung cancer xenografts the capability of our techniques to monitor in vivo collagenase induced increase in contrast agent delivery as a result of decreased IFP. These techniques can be applied to test drugs that affect angiogenesis and modulate interstitial fluid pressure and has the potential to be extended to cancer patients for assessing resistance to drug delivery. PMID:18638494

  17. Assessment of the effects of different sample perfusion procedures on phase-contrast tomographic images of mouse spinal cord

    NASA Astrophysics Data System (ADS)

    Stefanutti, E.; Sierra, A.; Miocchi, P.; Massimi, L.; Brun, F.; Maugeri, L.; Bukreeva, I.; Nurmi, A.; Begani Provinciali, G.; Tromba, G.; Gröhn, O.; Giove, F.; Cedola, A.; Fratini, M.

    2018-03-01

    Synchrotron X-ray Phase Contrast micro-Tomography (SXrPCμT) is a powerful tool in the investigation of biological tissues, including the central nervous system (CNS), and it allows to simultaneously detect the vascular and neuronal network avoiding contrast agents or destructive sample preparations. However, specific sample preparation procedures aimed to optimize the achievable contrast- and signal-to-noise ratio (CNR and SNR, respectively) are required. Here we report and discuss the effects of perfusion with two different fixative agents (ethanol and paraformaldehyde) and with a widely used contrast medium (MICROFIL®) on mouse spinal cord. As a main result, we found that ethanol enhances contrast at the grey/white matter interface and increases the contrast in correspondence of vascular features and fibres, thus providing an adequate spatial resolution to visualise the vascular network at the microscale. On the other hand, ethanol is known to induce tissue dehydration, likely reducing cell dimensions below the spatial resolution limit imposed by the experimental technique. Nonetheless, neurons remain well visible using either perfused paraformaldehyde or MICROFIL® compound, as these latter media do not affect tissues with dehydration effects. Paraformaldehyde appears as the best compromise: it is not a contrast agent, like MICROFIL®, but it is less invasive than ethanol and permits to visualise well both cells and blood vessels. However, a quantitative estimation of the relative grey matter volume of each sample has led us to conclude that no significant alterations in the grey matter extension compared to the white matter occur as a consequence of the perfusion procedures tested in this study.

  18. In Search of the Optimal Heart Perfusion Ultrasound Imaging Platform.

    PubMed

    Grishenkov, Dmitry; Gonon, Adrian; Janerot-Sjoberg, Birgitta

    2015-09-01

    Quantification of myocardial perfusion by contrast echocardiography remains a challenge. Existing imaging phantoms used to evaluate the performance of ultrasound scanners do not comply with perfusion basics in the myocardium, where perfusion and motion are inherently coupled. To contribute toward an improvement, we developed a contrast echocardiographic perfusion imaging platform based on an isolated rat heart coupled to an ultrasound scanner. Perfusion was assessed by using 3 different types of contrast agents: dextran-based Promiten (Meda AB, Solna, Sweden), phospholipid-shelled SonoVue (Bracco Diagnostics, Inc, Princeton, NJ), and polymer-shelled MB-pH5-RT, developed in-house. The myocardial video intensity was monitored over time from contrast agent administration to peak, and 2 characteristic constants were calculated by using an exponential fit: A, representing capillary volume; and β, representing inflow velocity. Acquired experimental evidence demonstrates that the application of all 3 contrast agents allows sonographic estimation of myocardial perfusion in the isolated rat heart. Video intensity maps show that an increase in contrast concentration increases the late-plateau values, A, mimicking increased capillary volume. Estimated values of the flow, proportional to A × β, increase when the pressure of the perfusate column increases from 80 to 110 cm of water. This finding is in agreement with the true values of the coronary flow increase measured by a flowmeter attached to the aortic cannula. The contrast echocardiographic perfusion imaging platform described holds promise for standardized evaluation and optimization of contrast perfusion ultrasound imaging in which real-time inflow curves at low acoustic power semiquantitatively reflect coronary flow. © 2015 by the American Institute of Ultrasound in Medicine.

  19. Fluorescent and scattering contrast agents in a mouse model of colorectal cancer

    NASA Astrophysics Data System (ADS)

    Winkler, Amy M.; Rice, Photini F. S.; Troutman, Timothy S.; Backer, Marina V.; Backer, Joseph M.; Drezek, Rebekah A.; Romanowski, Marek; Barton, Jennifer K.

    2008-02-01

    In previous work we have demonstrated the utility of laser-induced fluorescence (LIF) and optical coherence tomography (OCT) to identify adenoma in mouse models of colorectal cancer with high sensitivity and specificity. However, improved sensitivity to early disease, as well as the ability to distinguish confounders (e.g. fecal contamination, natural variations in mucosal thickness), is desired. In this study, we investigated the signal enhancement of fluorescent and scattering contrast agents in the colons of AOM-treated mice. The fluorescent tracer scVEGF/Cy, targeted to receptors for vascular endothelial growth factor, was visualized on a dual modality OCT/LIF endoscopic system with 1300-nm center wavelength OCT source and 635-nm LIF excitation. Scattering agents were tested with an 890-nm center wavelength endoscopic OCT system. Agents included nanoshells, 120-nm in diameter, and nanorods, 20-nm in diameter by 80-nm in length. Following imaging, colons were excised. Tissue treated with fluorophore was imaged on an epifluorescence microscope. Histological sections were obtained and stained with H&E and silver enhancer to verify disease and identify regions of gold uptake, respectively. Non-specific signal enhancement was observed with the scattering contrast agents. Specificity for adenoma was seen with the scVEGF/Cy dye.

  20. A Functional Iron Oxide Nanoparticles Modified with PLA-PEG-DG as Tumor-Targeted MRI Contrast Agent.

    PubMed

    Xiong, Fei; Hu, Ke; Yu, Haoli; Zhou, Lijun; Song, Lina; Zhang, Yu; Shan, Xiuhong; Liu, Jianping; Gu, Ning

    2017-08-01

    Tumor targeting could greatly promote the performance of magnetic nanomaterials as MRI (Magnetic Resonance Imaging) agent for tumor diagnosis. Herein, we reported a novel magnetic nanoparticle modified with PLA (poly lactic acid)-PEG (polyethylene glycol)-DG (D-glucosamine) as Tumor-targeted MRI Contrast Agent. In this work, we took use of the D-glucose passive targeting on tumor cells, combining it on PLA-PEG through amide reaction, and then wrapped the PLA-PEG-DG up to the Fe 3 O 4 @OA NPs. The stability and anti phagocytosis of Fe 3 O 4 @OA@PLA-PEG-DG was tested in vitro; the MRI efficiency and toxicity was also detected in vivo. These functional magnetic nanoparticles demonstrated good biocompatibility and stability both in vitro and in vivo. Cell experiments showed that Fe 3 O 4 @OA@PLA-PEG-DG nanoparticles exist good anti phagocytosis and high targetability. In vivo MRI images showed that the contrast effect of Fe 3 O 4 @OA@PLA-PEG-DG nanoparticles prevailed over the commercial non tumor-targeting magnetic nanomaterials MRI agent at a relatively low dose. The DG can validly enhance the tumor-targetting effect of Fe 3 O 4 @OA@PLA-PEG nanoparticle. Maybe MRI agents with DG can hold promise as tumor-targetting development in the future.

Top