Sample records for contrast sensitivity functions

  1. The Effect of Ocular Surface Regularity on Contrast Sensitivity and Straylight in Dry Eye.

    PubMed

    Koh, Shizuka; Maeda, Naoyuki; Ikeda, Chikako; Asonuma, Sanae; Ogawa, Mai; Hiraoka, Takahiro; Oshika, Tetsuro; Nishida, Kohji

    2017-05-01

    To investigate the association between visual function and ocular surface regularity in dry eye. We enrolled 52 eyes of 52 dry eye patients (34 dry eyes with superficial punctate keratopathy [SPK] in the central corneal region [central SPK] and 18 dry eyes without central SPK) and 20 eyes of 20 normal control subjects. All eyes had a best-corrected distance visual acuity better than 20/20. We measured two indices of contrast sensitivity function under photopic conditions: contrast sensitivity and letter contrast sensitivity. The area under the log contrast sensitivity function (AULCSF) was calculated from the obtained contrast sensitivity data. Straylight was quantified using a straylight meter. Dry eyes with central SPK had significantly decreased contrast sensitivity function, including AULCSF and letter contrast sensitivity than those without central SPK and normal eyes (P < 0.05 for each). While the straylight values in both dry eye groups did not differ, straylight values were greater than those in normal eyes (P < 0.05 for both). In dry eye, the AULCSF and letter contrast sensitivity negatively correlated with the central SPK score (R = -0.485, P < 0.001, and R = -0.541, P < 0.001, respectively). In dry eye, reduced contrast sensitivity in part results from central SPK overlying the optical zone and the increased straylight results from tear film instability rather than central SPK.

  2. Longitudinal measurements of luminance and chromatic contrast sensitivity: comparison between wavefront-guided LASIK and contralateral PRK for myopia.

    PubMed

    Barboni, Mirella Telles Salgueiro; Feitosa-Santana, Claudia; Barreto Junior, Jackson; Lago, Marcos; Bechara, Samir Jacob; Alves, Milton Ruiz; Ventura, Dora Fix

    2013-10-01

    The present study aimed to compare the postoperative contrast sensitivity functions between wavefront-guided LASIK eyes and their contralateral wavefront-guided PRK eyes. The participants were 11 healthy subjects (mean age=32.4 ± 6.2 years) who had myopic astigmatism. The spatial contrast sensitivity functions were measured before and three times after the surgery. Psycho and a Cambridge graphic board (VSG 2/4) were used to measure luminance, red-green, and blue-yellow spatial contrast sensitivity functions (from 0.85 to 13.1 cycles/degree). Longitudinal analysis and comparison between surgeries were performed. There was no significant contrast sensitivity change during the one-year follow-up measurements neither for LASIK nor for PRK eyes. The comparison between procedures showed no differences at 12 months postoperative. The present data showed similar contrast sensitivities during one-year follow-up of wave-front guided refractive surgeries. Moreover, one year postoperative data showed no differences in the effects of either wavefront-guided LASIK or wavefront-guided PRK on the luminance and chromatic spatial contrast sensitivity functions.

  3. Effect of aberrations in human eye on contrast sensitivity function

    NASA Astrophysics Data System (ADS)

    Quan, Wei; Wang, Feng-lin; Wang, Zhao-qi

    2011-06-01

    The quantitative analysis of the effect of aberrations in human eye on vision has important clinical value in the correction of aberrations. The wave-front aberrations of human eyes were measured with the Hartmann-Shack wave-front sensor and modulation transfer function (MTF) was computed from the wave-front aberrations. Contrast sensitivity function (CSF) was obtained from MTF and the retinal aerial image modulation (AIM). It is shown that the 2nd, 3rd, 4th, 5th, 6th Zernike aberrations deteriorate contrast sensitivity function. When the 2nd, 3rd, 4th, 5th, 6th Zernike aberrations are corrected high contrast sensitivity function can be obtained.

  4. A Normative Data Set for the Clinical Assessment of Achromatic and Chromatic Contrast Sensitivity Using a qCSF Approach.

    PubMed

    Kim, Yeon Jin; Reynaud, Alexandre; Hess, Robert F; Mullen, Kathy T

    2017-07-01

    The measurement of achromatic sensitivity has been an important tool for monitoring subtle changes in vision as the result of disease or response to therapy. In this study, we aimed to provide a normative data set for achromatic and chromatic contrast sensitivity functions within a common cone contrast space using an abbreviated measurement approach suitable for clinical practice. In addition, we aimed to provide comparisons of achromatic and chromatic binocular summation across spatial frequency. We estimated monocular cone contrast sensitivity functions (CCSFs) using a quick Contrast Sensitivity Function (qCSF) approach for achromatic as well as isoluminant, L/M cone opponent, and S cone opponent stimuli in a healthy population of 51 subjects. We determined the binocular CCSFs for achromatic and chromatic vision to evaluate the degree of binocular summation across spatial frequency for these three different mechanisms in a subset of 20 subjects. Each data set shows consistent contrast sensitivity across the population. They highlight the extremely high cone contrast sensitivity of L/M cone opponency compared with the S-cone and achromatic responses. We also find that the two chromatic sensitivities are correlated across the healthy population. In addition, binocular summation for all mechanisms depends strongly on stimulus spatial frequency. This study, using an approach well suited to the clinic, is the first to provide a comparative normative data set for the chromatic and achromatic contrast sensitivity functions, yielding quantitative comparisons of achromatic, L/M cone opponent, and S cone opponent chromatic sensitivities as a function of spatial frequency.

  5. The influence of L-opsin gene polymorphisms and neural ageing on spatio-chromatic contrast sensitivity in 20-71 year olds.

    PubMed

    Dees, Elise W; Gilson, Stuart J; Neitz, Maureen; Baraas, Rigmor C

    2015-11-01

    Chromatic contrast sensitivity may be a more sensitive measure of an individual's visual function than achromatic contrast sensitivity. Here, the first aim was to quantify individual- and age-related variations in chromatic contrast sensitivity to a range of spatial frequencies for stimuli along two complementary directions in color space. The second aim was to examine whether polymorphisms at specific amino acid residues of the L- and M-opsin genes (OPN1LW and OPN1MW) known to affect spectral tuning of the photoreceptors could influence spatio-chromatic contrast sensitivity. Chromatic contrast sensitivity functions were measured in 50 healthy individuals (20-71 years) employing a novel pseudo-isochromatic grating stimulus. The spatio-chromatic contrast sensitivity functions were found to be low pass for all subjects, independent of age and color vision. The results revealed a senescent decline in spatio-chromatic contrast sensitivity. There were considerable between-individual differences in sensitivity within each age decade for individuals 49 years old or younger, and age did not predict sensitivity for these age decades alone. Forty-six subjects (including a color deficient male and eight female carriers) were genotyped for L- and M-opsin genes. The Ser180Ala polymorphisms on the L-opsin gene were found to influence the subject's color discrimination and their sensitivity to spatio-chromatic patterns. The results expose the significant role of neural and genetic factors in the deterioration of visual function with increasing age. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Perceptual Learning Improves Contrast Sensitivity of V1 Neurons in Cats

    PubMed Central

    Hua, Tianmiao; Bao, Pinglei; Huang, Chang-Bing; Wang, Zhenhua; Xu, Jinwang

    2010-01-01

    Summary Background Perceptual learning has been documented in adult humans over a wide range of tasks. Although the often observed specificity of learning is generally interpreted as evidence for training-induced plasticity in early cortical areas, physiological evidence for training-induced changes in early visual cortical areas is modest, despite reports of learning-induced changes of cortical activities in fMRI studies. To reveal the physiological bases of perceptual learning, we combined psychophysical measurements with extracellular single-unit recording under anesthetized preparations, and examined the effects of training in grating orientation identification on both perceptual and neuronal contrast sensitivity functions of cats. Results We have found that training significantly improved perceptual contrast sensitivity of the cats to gratings with the spatial frequencies near the ‘trained’ spatial frequency, with stronger effects in the trained eye. Consistent with behavioral assessments, the mean contrast sensitivity of neurons recorded from V1 of the trained cats was significantly higher than that of neurons recorded from the untrained cats. Furthermore, in the trained cats, the contrast sensitivity of V1 neurons responding preferentially to stimuli presented via the trained eyes was significantly greater than that of neurons responding preferentially to stimuli presented via the ‘untrained’ eyes. The effect was confined to the trained spatial frequencies. In both trained and untrained cats, the neuronal contrast sensitivity functions derived from the contrast sensitivity of the individual neurons were highly correlated with behaviorally determined perceptual contrast sensitivity functions. Conclusions We suggest that training-induced neuronal contrast-gain in area V1 underlies behaviorally determined perceptual contrast sensitivity improvements. PMID:20451388

  7. Spatial contrast sensitivity at twilight: luminance, monocularity, and oxygenation.

    PubMed

    Connolly, Desmond M

    2010-05-01

    Visual performance in dim light is compromised by lack of oxygen (hypoxia). The possible influence of altered oxygenation on foveal contrast sensitivity under mesopic (twilight) viewing conditions is relevant to aircrew flying at night, including when using night vision devices, but is poorly documented. Foveal contrast sensitivity was measured binocularly and monocularly in 12 subjects at 7 spatial frequencies, ranging from 0.5 to approximately 16 cycles per degree, using sinusoidal Gabor patch gratings. Hypoxic performance breathing 14.1% oxygen, equivalent to altitude exposure at 3048 m (10,000 ft), was compared with breathing air at sea level (normoxia) at low photopic (28 cd x m(-2)), borderline upper mesopic (approximately 2.1 cd x m(-2)) and midmesopic (approximately 0.26 cd x m(-2)) luminance. Mesopic performance was also assessed breathing 100% oxygen (hyperoxia). Typical 'inverted U' log/log plots of the contrast sensitivity function were obtained, with elevated thresholds (reduced sensitivity) at lower luminance. Binocular viewing enhanced sensitivity by a factor approximating square root of 2 for most conditions, supporting neural summation of the contrast signal, but had greater influence at the lowest light level and highest spatial frequencies (8.26 and 16.51 cpd). Respiratory challenges had no effect. Contrast sensitivity is poorer when viewing monocularly and especially at midmesopic luminance, with relevance to night flying. The foveal contrast sensitivity function is unaffected by respiratory disturbance when twilight conditions favor cone vision, despite known effects on retinal illumination (pupil size). The resilience of the contrast sensitivity function belies the vulnerability of foveal low contrast acuity to mild hypoxia at mesopic luminance.

  8. Gain, noise, and contrast sensitivity of linear visual neurons

    NASA Technical Reports Server (NTRS)

    Watson, Andrew B.

    1990-01-01

    Contrast sensitivity is a measure of the ability of an observer to detect contrast signals of particular spatial and temporal frequencies. A formal definition of contrast sensitivity that can be applied to individual linear visual neurons is derived. A neuron is modeled by a contrast transfer function and its modulus, contrast gain, and by a noise power spectrum. The distributions of neural responses to signal and blank presentations are derived, and from these, a definition of contrast sensitivity is obtained. This formal definition may be used to relate the sensitivities of various populations of neurons, and to relate the sensitivities of neurons to that of the behaving animal.

  9. Chromatic spatial contrast sensitivity estimated by visual evoked cortical potential and psychophysics

    PubMed Central

    Barboni, M.T.S.; Gomes, B.D.; Souza, G.S.; Rodrigues, A.R.; Ventura, D.F.; Silveira, L.C.L.

    2013-01-01

    The purpose of the present study was to measure contrast sensitivity to equiluminant gratings using steady-state visual evoked cortical potential (ssVECP) and psychophysics. Six healthy volunteers were evaluated with ssVECPs and psychophysics. The visual stimuli were red-green or blue-yellow horizontal sinusoidal gratings, 5° × 5°, 34.3 cd/m2 mean luminance, presented at 6 Hz. Eight spatial frequencies from 0.2 to 8 cpd were used, each presented at 8 contrast levels. Contrast threshold was obtained by extrapolating second harmonic amplitude values to zero. Psychophysical contrast thresholds were measured using stimuli at 6 Hz and static presentation. Contrast sensitivity was calculated as the inverse function of the pooled cone contrast threshold. ssVECP and both psychophysical contrast sensitivity functions (CSFs) were low-pass functions for red-green gratings. For electrophysiology, the highest contrast sensitivity values were found at 0.4 cpd (1.95 ± 0.15). ssVECP CSF was similar to dynamic psychophysical CSF, while static CSF had higher values ranging from 0.4 to 6 cpd (P < 0.05, ANOVA). Blue-yellow chromatic functions showed no specific tuning shape; however, at high spatial frequencies the evoked potentials showed higher contrast sensitivity than the psychophysical methods (P < 0.05, ANOVA). Evoked potentials can be used reliably to evaluate chromatic red-green CSFs in agreement with psychophysical thresholds, mainly if the same temporal properties are applied to the stimulus. For blue-yellow CSF, correlation between electrophysiology and psychophysics was poor at high spatial frequency, possibly due to a greater effect of chromatic aberration on this kind of stimulus. PMID:23369980

  10. First- and second-order contrast sensitivity functions reveal disrupted visual processing following mild traumatic brain injury.

    PubMed

    Spiegel, Daniel P; Reynaud, Alexandre; Ruiz, Tatiana; Laguë-Beauvais, Maude; Hess, Robert; Farivar, Reza

    2016-05-01

    Vision is disrupted by traumatic brain injury (TBI), with vision-related complaints being amongst the most common in this population. Based on the neural responses of early visual cortical areas, injury to the visual cortex would be predicted to affect both 1(st) order and 2(nd) order contrast sensitivity functions (CSFs)-the height and/or the cut-off of the CSF are expected to be affected by TBI. Previous studies have reported disruptions only in 2(nd) order contrast sensitivity, but using a narrow range of parameters and divergent methodologies-no study has characterized the effect of TBI on the full CSF for both 1(st) and 2(nd) order stimuli. Such information is needed to properly understand the effect of TBI on contrast perception, which underlies all visual processing. Using a unified framework based on the quick contrast sensitivity function, we measured full CSFs for static and dynamic 1(st) and 2(nd) order stimuli. Our results provide a unique dataset showing alterations in sensitivity for both 1(st) and 2(nd) order visual stimuli. In particular, we show that TBI patients have increased sensitivity for 1(st) order motion stimuli and decreased sensitivity to orientation-defined and contrast-defined 2(nd) order stimuli. In addition, our data suggest that TBI patients' sensitivity for both 1(st) order stimuli and 2(nd) order contrast-defined stimuli is shifted towards higher spatial frequencies. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. Spatial Contrast Sensitivity in Adolescents with Autism Spectrum Disorders

    ERIC Educational Resources Information Center

    Koh, Hwan Cui; Milne, Elizabeth; Dobkins, Karen

    2010-01-01

    Adolescents with autism spectrum disorders (ASD) and typically developing (TD) controls underwent a rigorous psychophysical assessment that measured contrast sensitivity to seven spatial frequencies (0.5-20 cycles/degree). A contrast sensitivity function (CSF) was then fitted for each participant, from which four measures were obtained: visual…

  12. Immature visual neural system in children reflected by contrast sensitivity with adaptive optics correction

    PubMed Central

    Liu, Rong; Zhou, Jiawei; Zhao, Haoxin; Dai, Yun; Zhang, Yudong; Tang, Yong; Zhou, Yifeng

    2014-01-01

    This study aimed to explore the neural development status of the visual system of children (around 8 years old) using contrast sensitivity. We achieved this by eliminating the influence of higher order aberrations (HOAs) with adaptive optics correction. We measured HOAs, modulation transfer functions (MTFs) and contrast sensitivity functions (CSFs) of six children and five adults with both corrected and uncorrected HOAs. We found that when HOAs were corrected, children and adults both showed improvements in MTF and CSF. However, the CSF of children was still lower than the adult level, indicating the difference in contrast sensitivity between groups cannot be explained by differences in optical factors. Further study showed that the difference between the groups also could not be explained by differences in non-visual factors. With these results we concluded that the neural systems underlying vision in children of around 8 years old are still immature in contrast sensitivity. PMID:24732728

  13. Peripheral resolution and contrast sensitivity: Effects of stimulus drift.

    PubMed

    Venkataraman, Abinaya Priya; Lewis, Peter; Unsbo, Peter; Lundström, Linda

    2017-04-01

    Optimal temporal modulation of the stimulus can improve foveal contrast sensitivity. This study evaluates the characteristics of the peripheral spatiotemporal contrast sensitivity function in normal-sighted subjects. The purpose is to identify a temporal modulation that can potentially improve the remaining peripheral visual function in subjects with central visual field loss. High contrast resolution cut-off for grating stimuli with four temporal frequencies (0, 5, 10 and 15Hz drift) was first evaluated in the 10° nasal visual field. Resolution contrast sensitivity for all temporal frequencies was then measured at four spatial frequencies between 0.5 cycles per degree (cpd) and the measured stationary cut-off. All measurements were performed with eccentric optical correction. Similar to foveal vision, peripheral contrast sensitivity is highest for a combination of low spatial frequency and 5-10Hz drift. At higher spatial frequencies, there was a decrease in contrast sensitivity with 15Hz drift. Despite this decrease, the resolution cut-off did not vary largely between the different temporal frequencies tested. Additional measurements of contrast sensitivity at 0.5 cpd and resolution cut-off for stationary (0Hz) and 7.5Hz stimuli performed at 10, 15, 20 and 25° in the nasal visual field also showed the same characteristics across eccentricities. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  14. Effects of Retinal Morphology on Contrast Sensitivity and Reading Ability in Neovascular Age-Related Macular Degeneration

    PubMed Central

    Keane, Pearse A.; Patel, Praveen J.; Ouyang, Yanling; Chen, Fred K.; Ikeji, Felicia; Walsh, Alexander C.; Tufail, Adnan

    2010-01-01

    Purpose. To investigate the effect of changes in retinal morphology on contrast sensitivity and reading ability in patients with neovascular age-related macular degeneration (AMD) in the Avastin (bevacizumab; Genentech, South San Francisco, CA) for choroidal neovascularization (ABC) Trial. Methods. Contrast sensitivity obtained with Pelli-Robson charts, reading ability assessed with Minnesota Reading charts, and Early Treatment Diabetic Retinopathy Study (ETDRS) visual acuity (VA) obtained by protocol refraction, were recorded. Raw Stratus optical coherence tomography (OCT; Carl Zeiss Meditec, Inc., Dublin, CA) images were analyzed with the publicly available software OCTOR, which allows precise delineation of any retinal compartment of interest. Thickness and volume were calculated for neurosensory retina, subretinal fluid (SRF), subretinal tissue, and pigment epithelium detachment, and the resulting measurements were correlated with each visual function parameter. Results. One hundred twenty-two patients with newly diagnosed neovascular AMD and enrolled in the ABC Trial, were evaluated. Increased subretinal tissue volume correlated with decreased contrast sensitivity (Pearson's correlation coefficient, r = −0.4944, P = 0.001). A modest correlation was detected between SRF volume and contrast sensitivity (r = −0.2562, P = 0.004). Increased retinal thickness at the foveal center also correlated with decreased visual function (ETDRS VA: r = −0.4530, P < 0.001). Conclusions. The strongest correlation detected between the functional parameters assessed and any of the OCT-derived morphologic parameters was that between decreased contrast sensitivity and increased subretinal tissue. In the future, assessment of contrast sensitivity and reading ability, in combination with quantitative subanalysis of retinal compartments, may lead to the identification of parameters relevant to functional improvement and ultimate prognosis in patients with newly diagnosed neovascular AMD (www.controlled-trials.com number, ISRCTN83325075). PMID:20554607

  15. Predicting individual contrast sensitivity functions from acuity and letter contrast sensitivity measurements

    PubMed Central

    Thurman, Steven M.; Davey, Pinakin Gunvant; McCray, Kaydee Lynn; Paronian, Violeta; Seitz, Aaron R.

    2016-01-01

    Contrast sensitivity (CS) is widely used as a measure of visual function in both basic research and clinical evaluation. There is conflicting evidence on the extent to which measuring the full contrast sensitivity function (CSF) offers more functionally relevant information than a single measurement from an optotype CS test, such as the Pelli–Robson chart. Here we examine the relationship between functional CSF parameters and other measures of visual function, and establish a framework for predicting individual CSFs with effectively a zero-parameter model that shifts a standard-shaped template CSF horizontally and vertically according to independent measurements of high contrast acuity and letter CS, respectively. This method was evaluated for three different CSF tests: a chart test (CSV-1000), a computerized sine-wave test (M&S Sine Test), and a recently developed adaptive test (quick CSF). Subjects were 43 individuals with healthy vision or impairment too mild to be considered low vision (acuity range of −0.3 to 0.34 logMAR). While each test demands a slightly different normative template, results show that individual subject CSFs can be predicted with roughly the same precision as test–retest repeatability, confirming that individuals predominantly differ in terms of peak CS and peak spatial frequency. In fact, these parameters were sufficiently related to empirical measurements of acuity and letter CS to permit accurate estimation of the entire CSF of any individual with a deterministic model (zero free parameters). These results demonstrate that in many cases, measuring the full CSF may provide little additional information beyond letter acuity and contrast sensitivity. PMID:28006065

  16. Multi-step contrast sensitivity gauge

    DOEpatents

    Quintana, Enrico C; Thompson, Kyle R; Moore, David G; Heister, Jack D; Poland, Richard W; Ellegood, John P; Hodges, George K; Prindville, James E

    2014-10-14

    An X-ray contrast sensitivity gauge is described herein. The contrast sensitivity gauge comprises a plurality of steps of varying thicknesses. Each step in the gauge includes a plurality of recesses of differing depths, wherein the depths are a function of the thickness of their respective step. An X-ray image of the gauge is analyzed to determine a contrast-to-noise ratio of a detector employed to generate the image.

  17. Internal noise sources limiting contrast sensitivity.

    PubMed

    Silvestre, Daphné; Arleo, Angelo; Allard, Rémy

    2018-02-07

    Contrast sensitivity varies substantially as a function of spatial frequency and luminance intensity. The variation as a function of luminance intensity is well known and characterized by three laws that can be attributed to the impact of three internal noise sources: early spontaneous neural activity limiting contrast sensitivity at low luminance intensities (i.e. early noise responsible for the linear law), probabilistic photon absorption at intermediate luminance intensities (i.e. photon noise responsible for de Vries-Rose law) and late spontaneous neural activity at high luminance intensities (i.e. late noise responsible for Weber's law). The aim of this study was to characterize how the impact of these three internal noise sources vary with spatial frequency and determine which one is limiting contrast sensitivity as a function of luminance intensity and spatial frequency. To estimate the impact of the different internal noise sources, the current study used an external noise paradigm to factorize contrast sensitivity into equivalent input noise and calculation efficiency over a wide range of luminance intensities and spatial frequencies. The impact of early and late noise was found to drop linearly with spatial frequency, whereas the impact of photon noise rose with spatial frequency due to ocular factors.

  18. Uniform apparent contrast noise: A picture of the noise of the visual contrast detection system

    NASA Technical Reports Server (NTRS)

    Ahumada, A. J., Jr.; Watson, A. B.

    1984-01-01

    A picture which is a sample of random contrast noise is generated. The noise amplitude spectrum in each region of the picture is inversely proportional to spatial frequency contrast sensitivity for that region, assuming the observer fixates the center of the picture and is the appropriate distance from it. In this case, the picture appears to have approximately the same contrast everywhere. To the extent that contrast detection thresholds are determined by visual system noise, this picture can be regarded as a picture of the noise of that system. There is evidence that, at different eccentricities, contrast sensitivity functions differ only by a magnification factor. The picture was generated by filtering a sample of white noise with a filter whose frequency response is inversely proportional to foveal contrast sensitivity. It was then stretched by a space-varying magnification function. The picture summmarizes a noise linear model of detection and discrimination of contrast signals by referring the model noise to the input picture domain.

  19. Visual Contrast Sensitivity Functions Obtained from Untrained Observers Using Tracking and Staircase Procedures. Final Report.

    ERIC Educational Resources Information Center

    Geri, George A.; Hubbard, David C.

    Two adaptive psychophysical procedures (tracking and "yes-no" staircase) for obtaining human visual contrast sensitivity functions (CSF) were evaluated. The procedures were chosen based on their proven validity and the desire to evaluate the practical effects of stimulus transients, since tracking procedures traditionally employ gradual…

  20. Visual functioning and quality of life among the older people in Hong Kong.

    PubMed

    Leung, Jason C S; Kwok, Timothy C Y; Chan, Dicken C C; Yuen, Kay W K; Kwok, Anthony W L; Choy, Dicky T K; Lau, Edith M C; Leung, P C

    2012-08-01

    This study aimed to examine the association of visual functioning and health-related quality of life (HRQOL) among the older community in Hong Kong. This study used the baseline examination of a cohort study MrOs and MsOs (a large study for osteoporosis in men and women). This study was set in the Hong Kong community. A total of 4000 ambulatory community-dwelling Chinese men and women aged 65 years or above participated in this study. Health-related quality of life was assessed by Medical Outcomes Study Short Form-12 (SF-12), with physical component summary (PCS) and mental component summary (MCS) scores. Demographics, medical history, mental status, and quality of life were obtained from face-to-face interviews, using standard structured questionnaire. Visual functions (i.e., binocular visual acuity, contrast sensitivity, and stereopsis) were assessed by different visual tests after refraction corrections. Different visual functions were tested simultaneously in multiple ordinal logistic regression models. Better binocular visual acuity, contrast sensitivity, and stereopsis were associated with higher PCS. Visual acuity and contrast sensitivity was associated with PCS after adjustment of different visual functions and sex, age, education level, cognitive status, and history of diabetes in multivariate analysis, (OR = 0.73, 95% CI = 0.54 0.98) for low vision (≤6/24) compared with ≥6/9 in visual acuity and (OR = 1.34, 95% CI = 1.09 1.64) for contrast sensitivity row b 5-8 (best) compared with 0-1 (worst). MCS was only associated with visual acuity and contrast sensitivity, but no association was found after adjustment. Apparent association was found between visual functions and HRQOL among older community in Hong Kong. In addition to visual acuity, contrast sensitivity is also important, so eye care should also cover. Copyright © 2011 John Wiley & Sons, Ltd.

  1. Spatial contrast sensitivity vision loss in children with cortical visual impairment.

    PubMed

    Good, William V; Hou, Chuan; Norcia, Anthony M

    2012-11-19

    Although cortical visual impairment (CVI) is the leading cause of bilateral vision impairment in children in Western countries, little is known about the effects of CVI on visual function. The aim of this study was to compare visual evoked potential measures of contrast sensitivity and grating acuity in children with CVI with those of age-matched typically developing controls. The swept parameter visual evoked potential (sVEP) was used to measure contrast sensitivity and grating acuity in 34 children with CVI at 5 months to 5 years of age and in 16 age-matched control children. Contrast thresholds and spatial frequency thresholds (grating acuities) were derived by extrapolating the tuning functions to zero amplitude. These thresholds and maximal suprathreshold response amplitudes were compared between groups. Among 34 children with CVI, 30 had measurable but reduced contrast sensitivity with a median threshold of 10.8% (range 5.0%-30.0% Michelson), and 32 had measurable but reduced grating acuity with median threshold 0.49 logMAR (9.8 c/deg, range 5-14 c/deg). These thresholds were significantly reduced, compared with age-matched control children. In addition, response amplitudes over the entire sweep range for both measures were significantly diminished in children with CVI compared with those of control children. Our results indicate that spatial contrast sensitivity and response amplitudes are strongly affected by CVI. The substantial degree of loss in contrast sensitivity suggests that contrast is a sensitive measure for evaluating vision deficits in patients with CVI.

  2. Contrast Sensitivity Function Scores, Choices of Illuminated Stand Magnifiers, and Reading

    ERIC Educational Resources Information Center

    Gerritsen, Bryan

    2010-01-01

    Far too often, professionals focus almost solely on individuals' needs for magnification level for reading. Visual acuities are measured and decisions are made for low vision devices largely on the basis of acuity levels. Contrast sensitivity function is often overlooked as a critical need for and predictor of the selection and preference for low…

  3. Modelling the dependence of contrast sensitivity on grating area and spatial frequency.

    PubMed

    Rovamo, J; Luntinen, O; Näsänen, R

    1993-12-01

    We modelled the human foveal visual system in a detection task as a simple image processor comprising (i) low-pass filtering due to the optical transfer function of the eye, (ii) high-pass filtering of neural origin, (iii) addition of internal neural noise, and (iv) detection by a local matched filter. Its detection efficiency for gratings was constant up to a critical area but then decreased with increasing area. To test the model we measured Michelson contrast sensitivity as a function of grating area at spatial frequencies of 0.125-32 c/deg for simple vertical and circular cosine gratings. In circular gratings luminance was sinusoidally modulated as a function of the radius of the grating field. In agreement with the model, contrast sensitivity at all spatial frequencies increased in proportion to the square-root of grating area at small areas. When grating area exceeded critical area, the increase saturated and contrast sensitivity became independent of area at large grating areas. Spatial integration thus obeyed Piper's law at small grating areas. The critical area of spatial integration, marking the cessation of Piper's law, was constant in solid degrees at low spatial frequencies but inversely proportional to spatial frequency squared at medium and high spatial frequencies. At low spatial frequencies the maximum contrast sensitivity obtainable by spatial integration increased in proportion to spatial frequency but at high spatial frequencies it decreased in proportion to the cube of the increasing spatial frequency. The increase was due to high-pass filtering of neural origin (lateral inhibition) and the decrease was mainly due to the optical transfer function of the eye. Our model explained 95% of the total variance of the contrast sensitivity data.

  4. Longitudinal study of visual function in patients with relapsing-remitting multiple sclerosis with and without a history of optic neuritis.

    PubMed

    González Gómez, A; García-Ben, A; Soler García, A; García-Basterra, I; Padilla Parrado, F; García-Campos, J M

    2017-03-15

    The contrast sensitivity test determines the quality of visual function in patients with multiple sclerosis (MS). The purpose of this study is to analyse changes in visual function in patients with relapsing-remitting MS with and without a history of optic neuritis (ON). We conducted a longitudinal study including 61 patients classified into 3 groups as follows: a) disease-free patients (control group); b) patients with MS and no history of ON; and c) patients with MS and a history of unilateral ON. All patients underwent baseline and 6-year follow-up ophthalmologic examinations, which included visual acuity and monocular and binocular Pelli-Robson contrast sensitivity tests. Monocular contrast sensitivity was significantly lower in MS patients with and without a history of ON than in controls both at baseline (P=.00 and P=.01, respectively) and at 6 years (P=.01 and P=.02). Patients with MS and no history of ON remained stable throughout follow-up whereas those with a history of ON displayed a significant loss of contrast sensitivity (P=.01). Visual acuity and binocular contrast sensitivity at baseline and at 6 years was significantly lower in the group of patients with a history of ON than in the control group (P=.003 and P=.002 vs P=.006 and P=.005) and the group with no history of ON (P=.04 and P=.038 vs P=.008 and P=.01). However, no significant differences were found in follow-up results (P=.1 and P=.5). Monocular Pelli-Robson contrast sensitivity test may be used to detect changes in visual function in patients with ON. Copyright © 2017 The Author(s). Publicado por Elsevier España, S.L.U. All rights reserved.

  5. A novel method for assessing contrast sensitivity in the beagle dog is sensitive to age and an antioxidant enriched food.

    PubMed

    de Rivera, Christina; Boutet, Isabelle; Zicker, Steven C; Milgram, Norton W

    2005-03-01

    Tasks requiring visual discrimination are commonly used in assessment of canine cognitive function. However, little is known about canine visual processing, and virtually nothing is known about the effects of age on canine visual function. This study describes a novel behavioural method developed to assess one aspect of canine visual function, namely contrast sensitivity. Four age groups (young, middle aged, old, and senior) were studied. We also included a group of middle aged to old animals that had been maintained for at least 4 years on a specially formulated food containing a broad spectrum of antioxidants and mitochondrial cofactors. Performance of this group was compared with a group in the same age range maintained on a control diet. In the first phase, all animals were trained to discriminate between two high contrast shapes. In the second phase, contrast was progressively reduced by increasing the luminance of the shapes. Performance decreased as a function of age, but the differences did not achieve statistical significance, possibly because of a small sample size in the young group. All age groups were able to acquire the initial discrimination, although the two older age groups showed slower learning. Errors increased with decreasing contrast with the maximal number of errors for the 1% contrast shape. Also, all animals on the antioxidant diet learned the task and had significantly fewer errors at the high contrast compared with the animals on the control diet. The initial results suggest that contrast sensitivity deteriorates with age in the canine while form perception is largely unaffected by age.

  6. Optical defocus: differential effects on size and contrast letter recognition thresholds.

    PubMed

    Rabin, J

    1994-02-01

    To determine if optical defocus produces a greater reduction in visual acuity or small-letter contrast sensitivity. Letter charts were used to measure visual acuity and small-letter contrast sensitivity (20/25 Snellen equivalent) as a function of optical defocus. Letter size (acuity) and contrast (contrast sensitivity) were varied in equal logarithmic steps to make the task the same for the two types of measurement. Both visual acuity and contrast sensitivity declined with optical defocus, but the effect was far greater in the contrast domain. However, measurement variability also was greater for contrast sensitivity. After correction for this variability, measurement in the contrast domain still proved to be a more sensitive (1.75x) index of optical defocus. Small-letter contrast sensitivity is a powerful technique for detecting subtle amounts of optical defocus. This adjunctive approach may be useful when there are small changes in resolution that are not detected by standard measures of visual acuity. Potential applications include evaluating the course of vision in refractive surgery, classification of cataracts, detection of corneal or macular edema, and detection of visual loss in the aging eye. Evaluation of candidates for occupations requiring unique visual abilities also may be enhanced by measuring resolution in the contrast domain.

  7. Functional vision in children with perinatal brain damage.

    PubMed

    Alimović, Sonja; Jurić, Nikolina; Bošnjak, Vlatka Mejaški

    2014-09-01

    Many authors have discussed the effects of visual stimulations on visual functions, but there is no research about the effects on using vision in everyday activities (i.e. functional vision). Children with perinatal brain damage can develop cerebral visual impairment with preserved visual functions (e.g. visual acuity, contrast sensitivity) but poor functional vision. Our aim was to discuss the importance of assessing and stimulating functional vision in children with perinatal brain damage. We assessed visual functions (grating visual acuity, contrast sensitivity) and functional vision (the ability of maintaining visual attention and using vision in communication) in 99 children with perinatal brain damage and visual impairment. All children were assessed before and after the visual stimulation program. Our first assessment results showed that children with perinatal brain damage had significantly more problems in functional vision than in basic visual functions. During the visual stimulation program both variables of functional vision and contrast sensitivity improved significantly, while grating acuity improved only in 2.7% of children. We also found that improvement of visual attention significantly correlated to improvement on all other functions describing vision. Therefore, functional vision assessment, especially assessment of visual attention is indispensable in early monitoring of child with perinatal brain damage.

  8. Genetic influence on contrast sensitivity in middle-aged male twins.

    PubMed

    Cronin-Golomb, Alice; Panizzon, Matthew S; Lyons, Michael J; Franz, Carol E; Grant, Michael D; Jacobson, Kristen C; Eisen, Seth A; Laudate, Thomas M; Kremen, William S

    2007-07-01

    Contrast sensitivity is strongly associated with daily functioning among older adults, but the genetic and environmental contributions to this ability are unknown. Using the classical twin method, we addressed this issue by examining contrast sensitivity at five spatial frequencies (1.5-18 cycles per degree) in 718 middle-aged male twins from the Vietnam Era Twin Study of Aging (VETSA). Heritability estimates were modest (14-38%), whereas individual-specific environmental influences accounted for 62-86% of the variance. Identifying the types of individual-specific events that impact contrast sensitivity may suggest interventions to modulate this ability and thereby improve overall quality of life as adults age.

  9. Visual Contrast Sensitivity in Early-Stage Parkinson's Disease.

    PubMed

    Ming, Wendy; Palidis, Dimitrios J; Spering, Miriam; McKeown, Martin J

    2016-10-01

    Visual impairments are frequent in Parkinson's disease (PD) and impact normal functioning in daily activities. Visual contrast sensitivity is a powerful nonmotor sign for discriminating PD patients from controls. However, it is usually assessed with static visual stimuli. Here we examined the interaction between perception and eye movements in static and dynamic contrast sensitivity tasks in a cohort of mildly impaired, early-stage PD patients. Patients (n = 13) and healthy age-matched controls (n = 12) viewed stimuli of various spatial frequencies (0-8 cyc/deg) and speeds (0°/s, 10°/s, 30°/s) on a computer monitor. Detection thresholds were determined by asking participants to adjust luminance contrast until they could just barely see the stimulus. Eye position was recorded with a video-based eye tracker. Patients' static contrast sensitivity was impaired in the intermediate spatial-frequency range and this impairment correlated with fixational instability. However, dynamic contrast sensitivity and patients' smooth pursuit were relatively normal. An independent component analysis revealed contrast sensitivity profiles differentiating patients and controls. Our study simultaneously assesses perceptual contrast sensitivity and eye movements in PD, revealing a possible link between fixational instability and perceptual deficits. Spatiotemporal contrast sensitivity profiles may represent an easily measurable metric as a component of a broader combined biometric for nonmotor features observed in PD.

  10. Visible Contrast Energy Metrics for Detection and Discrimination

    NASA Technical Reports Server (NTRS)

    Ahumada, Albert; Watson, Andrew

    2013-01-01

    Contrast energy was proposed by Watson, Robson, & Barlow as a useful metric for representing luminance contrast target stimuli because it represents the detectability of the stimulus in photon noise for an ideal observer. Like the eye, the ear is a complex transducer system, but relatively simple sound level meters are used to characterize sounds. These meters provide a range of frequency sensitivity functions and integration times depending on the intended use. We propose here the use of a range of contrast energy measures with different spatial frequency contrast sensitivity weightings, eccentricity sensitivity weightings, and temporal integration times. When detection threshold are plotting using such measures, the results show what the eye sees best when these variables are taken into account in a standard way. The suggested weighting functions revise the Standard Spatial Observer for luminance contrast detection and extend it into the near periphery. Under the assumption that the detection is limited only by internal noise, discrimination performance can be predicted by metrics based on the visible energy of the difference images

  11. Perceptual learning improves contrast sensitivity, visual acuity, and foveal crowding in amblyopia.

    PubMed

    Barollo, Michele; Contemori, Giulio; Battaglini, Luca; Pavan, Andrea; Casco, Clara

    2017-01-01

    Amblyopic observers present abnormal spatial interactions between a low-contrast sinusoidal target and high-contrast collinear flankers. It has been demonstrated that perceptual learning (PL) can modulate these low-level lateral interactions, resulting in improved visual acuity and contrast sensitivity. We measured the extent and duration of generalization effects to various spatial tasks (i.e., visual acuity, Vernier acuity, and foveal crowding) through PL on the target's contrast detection. Amblyopic observers were trained on a contrast-detection task for a central target (i.e., a Gabor patch) flanked above and below by two high-contrast Gabor patches. The pre- and post-learning tasks included lateral interactions at different target-to-flankers separations (i.e., 2, 3, 4, 8λ) and included a range of spatial frequencies and stimulus durations as well as visual acuity, Vernier acuity, contrast-sensitivity function, and foveal crowding. The results showed that perceptual training reduced the target's contrast-detection thresholds more for the longest target-to-flanker separation (i.e., 8λ). We also found generalization of PL to different stimuli and tasks: contrast sensitivity for both trained and untrained spatial frequencies, visual acuity for Sloan letters, and foveal crowding, and partially for Vernier acuity. Follow-ups after 5-7 months showed not only complete maintenance of PL effects on visual acuity and contrast sensitivity function but also further improvement in these tasks. These results suggest that PL improves facilitatory lateral interactions in amblyopic observers, which usually extend over larger separations than in typical foveal vision. The improvement in these basic visual spatial operations leads to a more efficient capability of performing spatial tasks involving high levels of visual processing, possibly due to the refinement of bottom-up and top-down networks of visual areas.

  12. Genetic Influence on Contrast Sensitivity in Middle-Aged Male Twins

    PubMed Central

    Cronin-Golomb, Alice; Panizzon, Matthew S.; Lyons, Michael J.; Franz, Carol E.; Grant, Michael D.; Jacobson, Kristen C.; Eisen, Seth A.; Laudate, Thomas M.; Kremen, William S.

    2007-01-01

    Contrast sensitivity is strongly associated with daily functioning among older adults, but the genetic and environmental contributions to this ability are unknown. Using the classical twin method, we addressed this issue by examining contrast sensitivity at five spatial frequencies (1.5–18 cycles per degree) in 718 middle-aged male twins from the Vietnam Era Twin Study of Aging (VETSA). Heritability estimates were modest (14%–38%), whereas individual-specific environmental influences accounted for 62%–86% of the variance. Identifying the types of individual-specific events that impact contrast sensitivity may suggest interventions to modulate this ability and thereby improve overall quality of life as adults age. PMID:17604073

  13. Effect of anterior capsule contraction on visual function after cataract surgery.

    PubMed

    Hayashi, Ken; Hayashi, Hideyuki

    2007-11-01

    To examine the effect of contraction of the anterior capsule opening after cataract surgery on visual acuity and contrast sensitivity. Hayashi Eye Hospital, Fukuoka, Japan. Thirty-two eyes of 32 consecutive patients who showed marked contraction of the anterior capsule opening after implantation of an intraocular lens were recruited. The area of the anterior capsule opening was measured by Scheimpflug videophotography before and after neodymium:YAG (Nd:YAG) laser anterior capsulotomy and was correlated with visual acuity and contrast sensitivity. After Nd:YAG laser anterior capsulotomy, the mean area of the anterior capsule opening increased significantly from 8.2 mm(2) to 18.0 mm(2) (P<.0001). Contrast sensitivity at most visual angles also improved significantly after Nd:YAG anterior capsulotomy, although visual acuity did not. The area of the anterior capsule opening before anterior capsulotomy was correlated significantly with contrast sensitivity but not with visual acuity, whereas there was no correlation between the opening area after anterior capsulotomy and visual acuity or contrast sensitivity. Contraction of the anterior capsule opening after cataract surgery significantly diminished contrast sensitivity in proportion to the opening area but did not markedly worsen visual acuity. Neodymium:YAG laser anterior capsulotomy improved contrast sensitivity.

  14. Functional changes after treatment of optic pathway paediatric low-grade gliomas

    PubMed Central

    Magli, A; Forte, R; Cinalli, G; Esposito, F; Parisi, S; Capasso, M; Papparella, A

    2013-01-01

    Objective To evaluate the functional changes after treatment of paediatric optic pathway gliomas (OPGs). Methods All patients with monofocal OPG seen from January 2004 to January 2011 were included. Best corrected visual acuity (BCVA, LogMAR), contrast sensitivity (Hiding-Heidi low-contrast ‘face' test (HH) and Pelli−Robson (PR) contrast sensitivity test), and the Color Test (Ishihara plate) were obtained. Results Twenty-one patients (10 boys and 11 girls with a mean age of 5.5±4.4 years at diagnosis) were included in the study. Neurofibromatosis was present in four cases. Eighteen patients (85.7%) were treated with initial surgery and three patients (14.3%) with initial chemotherapy. BCVA was 0.67±0.8 LogMAR at baseline and 0.62±0.9 LogMAR at last visit (P=0.41). The Color test was not significantly changed at last visit (P=0.62). Contrast sensitivity with the HH test was 9.1±11.1% at baseline and 3.8±6.4% at last visit (P=0.03). Contrast sensitivity with PR chart was 1.33±0.9log at baseline and 1.05±0.7 log at last visit (P=0.005). A reduction in contrast sensitivity at both tests was significantly greater in patients who relapsed than in patients who did not relapse (P=0.001). Conclusion After the treatment of paediatric optic pathway low-grade gliomas, a reduction in contrast sensitivity during follow-up was observed and may be correlated with tumour relapses. PMID:23970029

  15. Spherical aberration yielding optimum visual performance: Evaluation of intraocular lenses using adaptive optics simulation

    PubMed Central

    Werner, John S.; Elliott, Sarah L.; Choi, Stacey S.; Doble, Nathan

    2009-01-01

    PURPOSE To evaluate the influence of spherical aberration on contrast sensitivity using adaptive optics. SETTING Vision Science and Advanced Retinal Imaging Laboratory, Department of Ophthalmology & Vision Science, University of California, Davis Medical Center, Sacramento, California, USA. METHODS Contrast sensitivity at 8 cycles per degree was evaluated using an adaptive optics system that permitted aberrations to be measured with a Shack-Hartman wavefront sensor and controlled by a 109 actuator continuous-surface deformable mirror that was at a plane conjugate to the observer’s pupil. Vertical Gabor patches were viewed through a 6.3 mm diameter pupil conjugate aperture. Contrast sensitivity was measured with the deformable mirror set to produce 1 of 5 spherical aberration profiles (−0.2 to +0.2 μm). Contrast sensitivity over the range of spherical aberration was fitted with a polynomial function. RESULTS Three observers (age 21 to 24 years) participated. The measured total mean spherical aberration resulting from the spherical aberration profiles produced by the deformable mirror was between −0.15 μm and +0.25 μm. The peak contrast sensitivity of this function for the 3 observers combined occurred at +0.06 μm of spherical aberration. The peak contrast sensitivity was also achieved with positive spherical aberration for observer (mean 0.09). CONCLUSION There was intersubject variability in the measurements; however, the average visual performance was best with the introduction of a small positive spherical aberration. PMID:19545813

  16. Stereo chromatic contrast sensitivity model to blue-yellow gratings.

    PubMed

    Yang, Jiachen; Lin, Yancong; Liu, Yun

    2016-03-07

    As a fundamental metric of human visual system (HVS), contrast sensitivity function (CSF) is typically measured by sinusoidal gratings at the detection of thresholds for psychophysically defined cardinal channels: luminance, red-green, and blue-yellow. Chromatic CSF, which is a quick and valid index to measure human visual performance and various retinal diseases in two-dimensional (2D) space, can not be directly applied into the measurement of human stereo visual performance. And no existing perception model considers the influence of chromatic CSF of inclined planes on depth perception in three-dimensional (3D) space. The main aim of this research is to extend traditional chromatic contrast sensitivity characteristics to 3D space and build a model applicable in 3D space, for example, strengthening stereo quality of 3D images. This research also attempts to build a vision model or method to check human visual characteristics of stereo blindness. In this paper, CRT screen was clockwise and anti-clockwise rotated respectively to form the inclined planes. Four inclined planes were selected to investigate human chromatic vision in 3D space and contrast threshold of each inclined plane was measured with 18 observers. Stimuli were isoluminant blue-yellow sinusoidal gratings. Horizontal spatial frequencies ranged from 0.05 to 5 c/d. Contrast sensitivity was calculated as the inverse function of the pooled cone contrast threshold. According to the relationship between spatial frequency of inclined plane and horizontal spatial frequency, the chromatic contrast sensitivity characteristics in 3D space have been modeled based on the experimental data. The results show that the proposed model can well predicted human chromatic contrast sensitivity characteristics in 3D space.

  17. Characterization of image heterogeneity using 2D Minkowski functionals increases the sensitivity of detection of a targeted MRI contrast agent.

    PubMed

    Canuto, Holly C; McLachlan, Charles; Kettunen, Mikko I; Velic, Marko; Krishnan, Anant S; Neves, Andre' A; de Backer, Maaike; Hu, D-E; Hobson, Michael P; Brindle, Kevin M

    2009-05-01

    A targeted Gd(3+)-based contrast agent has been developed that detects tumor cell death by binding to the phosphatidylserine (PS) exposed on the plasma membrane of dying cells. Although this agent has been used to detect tumor cell death in vivo, the differences in signal intensity between treated and untreated tumors was relatively small. As cell death is often spatially heterogeneous within tumors, we investigated whether an image analysis technique that parameterizes heterogeneity could be used to increase the sensitivity of detection of this targeted contrast agent. Two-dimensional (2D) Minkowski functionals (MFs) provided an automated and reliable method for parameterization of image heterogeneity, which does not require prior assumptions about the number of regions or features in the image, and were shown to increase the sensitivity of detection of the contrast agent as compared to simple signal intensity analysis. (c) 2009 Wiley-Liss, Inc.

  18. Optical transfer function in corneal topography for clinical contrast sensitivity analysis

    NASA Astrophysics Data System (ADS)

    Bende, Thomas; Jean, Benedikt J.; Oltrup, Theo

    2000-06-01

    Customized ablation aiming to optimize visual acuity in refractive surgery requires objective data on corneal surface, like the contrast sensitivity. Fast ray tracing, using the high resolution 3-D elevation data in conjunction with Snell's law describe the diffraction of the incident rays and the resulting image on a 'virtual retina.' A retroprojection leads to a 'surface quality map.' For objective contrast sensitivity measurement a sinus (or cos) wave of different frequencies is used for a calculated projection in analogy to the clinical contrast sensitivity charts. The projection on the individual cornea surface is analyzed for the Modular Transfer Function (MTF) and the Phase Shift Function (PSF) as a function of frequencies. PSF, not yet clinically used, is a parameter to determine even minimal corneal tilt. The resulting corneal aberration map (CAM) as described here and applied to a 4.5 D PRK (OZD equals 6.5 mm) reveals that the area of minimal aberration measures only 4.2 mm. The CAM can likewise be used to describe the 'quality' of a laser system's ablation pattern based upon the area of minimal optical aberrations. The CAM only describes surface aberration with high resolution, an advantage over wave front sensing which measures all accumulated optical aberrations including the changing ones of the lens during accommodation and the transient ones due to lens aging and early cataract formation.

  19. Visual functions and interocular interactions in anisometropic children with and without amblyopia.

    PubMed

    Lai, Xin Jie; Alexander, Jack; He, Mingguang; Yang, Zhikuan; Suttle, Catherine

    2011-08-29

    In uncorrected anisometropia, protracted dichoptic stimulation may result in interocular inhibition, which may be a contributing factor in amblyopia development. This study investigates the relationship between interocular interactions and anisometropic amblyopia. Three visual functions (low-contrast acuity, contrast sensitivity, and alignment sensitivity) were measured in the nondominant eye of 44 children aged 5 to 11 years: 10 with normal vision, 17 with anisometropia without amblyopia, and 17 with anisometropic amblyopia. The dominant eye was either fully or partially occluded. The difference in nondominant eye visual function between the full-and partial-occlusion conditions was termed the interaction index. The index of each visual function was compared between subject groups. A higher index indicates stronger inhibition of nondominant eye function with partial occlusion of the dominant eye. Amblyopic children had 6 months of therapy (refractive correction and occlusion), and the reduction in interocular difference in high-contrast acuity was regarded as the treatment outcome. The relationships of the interaction index with the degree of anisometropia, the severity of amblyopia, and the treatment outcomes were examined. The acuity interaction index was significantly higher in anisometropic children with amblyopia than in those without (P = 0.003). It was positively correlated with the degree of anisometropia (r(s) = 0.35, P = 0.042) and the amblyopic treatment outcomes (r(s) = 0.54, P = 0.038). No such difference or association was found between the contrast sensitivity or alignment sensitivity interaction index and anisometropic amblyopia. Interocular interactions are associated with amblyopia, the degree of anisometropia, and amblyopia treatment outcomes, but these associations are visual function dependent.

  20. Clinical color vision testing and correlation with visual function.

    PubMed

    Zhao, Jiawei; Davé, Sarita B; Wang, Jiangxia; Subramanian, Prem S

    2015-09-01

    To determine if Hardy-Rand-Rittler (H-R-R) and Ishihara testing are accurate estimates of color vision in subjects with acquired visual dysfunction. Assessment of diagnostic tools. Twenty-two subjects with optic neuropathy (aged 18-65) and 18 control subjects were recruited prospectively from an outpatient clinic. Individuals with visual acuity (VA) <20/200 or with congenital color blindness were excluded. All subjects underwent a comprehensive eye examination including VA, color vision, and contrast sensitivity testing. Color vision was assessed using H-R-R and Ishihara plates and Farnsworth D-15 (D-15) discs. D-15 is the accepted standard for detecting and classifying color vision deficits. Contrast sensitivity was measured using Pelli-Robson contrast sensitivity charts. No relationship was found between H-R-R and D-15 scores (P = .477). H-R-R score and contrast sensitivity were positively correlated (P = .003). On multivariate analysis, contrast sensitivity (β = 8.61, P < .001) and VA (β = 2.01, P = .022) both showed association with H-R-R scores. Similar to H-R-R, Ishihara score did not correlate with D-15 score (P = .973), but on multivariate analysis was related to contrast sensitivity (β = 8.69, P < .001). H-R-R and Ishihara scores had an equivalent relationship with contrast sensitivity (P = .069). Neither H-R-R nor Ishihara testing appears to assess color identification in patients with optic neuropathy. Both H-R-R and Ishihara testing are correlated with contrast sensitivity, and these tests may be useful clinical surrogates for contrast sensitivity testing. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. A hierarchical Bayesian approach to adaptive vision testing: A case study with the contrast sensitivity function.

    PubMed

    Gu, Hairong; Kim, Woojae; Hou, Fang; Lesmes, Luis Andres; Pitt, Mark A; Lu, Zhong-Lin; Myung, Jay I

    2016-01-01

    Measurement efficiency is of concern when a large number of observations are required to obtain reliable estimates for parametric models of vision. The standard entropy-based Bayesian adaptive testing procedures addressed the issue by selecting the most informative stimulus in sequential experimental trials. Noninformative, diffuse priors were commonly used in those tests. Hierarchical adaptive design optimization (HADO; Kim, Pitt, Lu, Steyvers, & Myung, 2014) further improves the efficiency of the standard Bayesian adaptive testing procedures by constructing an informative prior using data from observers who have already participated in the experiment. The present study represents an empirical validation of HADO in estimating the human contrast sensitivity function. The results show that HADO significantly improves the accuracy and precision of parameter estimates, and therefore requires many fewer observations to obtain reliable inference about contrast sensitivity, compared to the method of quick contrast sensitivity function (Lesmes, Lu, Baek, & Albright, 2010), which uses the standard Bayesian procedure. The improvement with HADO was maintained even when the prior was constructed from heterogeneous populations or a relatively small number of observers. These results of this case study support the conclusion that HADO can be used in Bayesian adaptive testing by replacing noninformative, diffuse priors with statistically justified informative priors without introducing unwanted bias.

  2. A hierarchical Bayesian approach to adaptive vision testing: A case study with the contrast sensitivity function

    PubMed Central

    Gu, Hairong; Kim, Woojae; Hou, Fang; Lesmes, Luis Andres; Pitt, Mark A.; Lu, Zhong-Lin; Myung, Jay I.

    2016-01-01

    Measurement efficiency is of concern when a large number of observations are required to obtain reliable estimates for parametric models of vision. The standard entropy-based Bayesian adaptive testing procedures addressed the issue by selecting the most informative stimulus in sequential experimental trials. Noninformative, diffuse priors were commonly used in those tests. Hierarchical adaptive design optimization (HADO; Kim, Pitt, Lu, Steyvers, & Myung, 2014) further improves the efficiency of the standard Bayesian adaptive testing procedures by constructing an informative prior using data from observers who have already participated in the experiment. The present study represents an empirical validation of HADO in estimating the human contrast sensitivity function. The results show that HADO significantly improves the accuracy and precision of parameter estimates, and therefore requires many fewer observations to obtain reliable inference about contrast sensitivity, compared to the method of quick contrast sensitivity function (Lesmes, Lu, Baek, & Albright, 2010), which uses the standard Bayesian procedure. The improvement with HADO was maintained even when the prior was constructed from heterogeneous populations or a relatively small number of observers. These results of this case study support the conclusion that HADO can be used in Bayesian adaptive testing by replacing noninformative, diffuse priors with statistically justified informative priors without introducing unwanted bias. PMID:27105061

  3. Ganglion Cell Loss and Age-Related Visual Loss: A Cortical Pooling Analysis

    PubMed Central

    SCHMIDT, LAURA A.; LY-SCHROEDER, EMILY; SWANSON, WILLIAM H.

    2006-01-01

    Purpose To evaluate the ability of the cortical pooling model to predict the effects of random, mild ganglion cell loss, we compared the predictions of the model with the age-related loss and variability in achromatic and chromatic contrast sensitivity. Methods The relative sensitivity to small (0.5°) and large (3.0°) stimuli was compared in older (mean = 67 years, n = 27) and younger (mean = 23 years, n = 32) adults. Contrast sensitivity for modulations along the luminance, equiluminant L-cone, and equiluminant S-cone axes was assessed at the fovea and at four peripheral locations (12°). Results When the stimuli were large, threshold measurements obtained from all participants were reliable and well within the range of modulations along the chromatic axes that could be produced by the phosphors of the CRT. For the large stimuli, neither long- nor short-term variability increased as a function of age. Increasing the size of the stimulus did not decrease the magnitude of the age-related losses when the stimulus was chromatic, and visual losses observed with large chromatic stimuli were not different from those obtained with small achromatic stimuli. Moreover, chromatic contrast sensitivity assessments identified significant visual losses in four individuals who were not identified by achromatic contrast sensitivity assessments and only missed identifying one individual with significant losses in achromatic contrast sensitivity. Conclusions The declines in achromatic and chromatic sensitivity as a function of age (0.4 – 0.7 dB per decade) were similar to those obtained in previous studies of achromatic and chromatic perimetry and are consistent with the loss of retinal ganglion cells reported in histologic studies. The results of this study are consistent with the predictions the cortical pooling model makes for both variability and contrast sensitivity. These findings emphasize that selective visual impairments do not necessarily reflect preferential damage to a single ganglion cell class and that it is important to include the influence of higher cortical processing when quantifying the relation between ganglion cells and visual function. PMID:16840870

  4. The Ohio Contrast Cards: Visual Performance in a Pediatric Low-vision Site

    PubMed Central

    Hopkins, Gregory R.; Dougherty, Bradley E.; Brown, Angela M.

    2017-01-01

    SIGNIFICANCE This report describes the first clinical use of the Ohio Contrast Cards, a new test that measures the maximum spatial contrast sensitivity of low-vision patients who cannot recognize and identify optotypes and for whom the spatial frequency of maximum contrast sensitivity is unknown. PURPOSE To compare measurements of the Ohio Contrast Cards to measurements of three other vision tests and a vision-related quality-of-life questionnaire obtained on partially sighted students at Ohio State School for the Blind. METHODS The Ohio Contrast Cards show printed square-wave gratings at very low spatial frequency (0.15 cycle/degree). The patient looks to the left/right side of the card containing the grating. Twenty-five students (13 to 20 years old) provided four measures of visual performance: two grating card tests (the Ohio Contrast Cards and the Teller Acuity Cards) and two letter charts (the Pelli-Robson contrast chart and the Bailey-Lovie acuity chart). Spatial contrast sensitivity functions were modeled using constraints from the grating data. The Impact of Vision Impairment on Children questionnaire measured vision-related quality of life. RESULTS Ohio Contrast Card contrast sensitivity was always less than 0.19 log10 units below the maximum possible contrast sensitivity predicted by the model; average Pelli-Robson letter contrast sensitivity was near the model prediction, but 0.516 log10 units below the maximum. Letter acuity was 0.336 logMAR below the grating acuity results. The model estimated the best testing distance in meters for optimum Pelli-Robson contrast sensitivity from the Bailey-Lovie acuity as distance = 1.5 − logMAR for low-vision patients. Of the four vision tests, only Ohio Contrast Card contrast sensitivity was independently and statistically significantly correlated with students' quality of life. CONCLUSIONS The Ohio Contrast Cards combine a grating stimulus, a looking indicator behavior, and contrast sensitivity measurement. They show promise for the clinical objective of advising the patient and his/her caregivers about the success the patient is likely to enjoy in tasks of everyday life. PMID:28972542

  5. Effect of a modified optic edge design on visual function: textured-edge versus round-anterior, slope-side edge.

    PubMed

    Hayashi, Ken; Hayashi, Hideyuki

    2004-08-01

    To compare the impairment in visual function caused by glare with 2 acrylic intraocular lenses (IOLs) with different modified optic edges. Hayashi Eye Hospital, Fukuoka, Japan. Fifty-four patients had implantation of an IOL with a textured edge (Alcon MA60AC) in 1 eye and an IOL with a round-anterior, sloped-sided edge (AMO AR40e) in the opposite eye. Visual acuity was measured at 5 contrast visual targets (100%, 25%, 10%, 5%, and 2.5%) (contrast visual acuity) under photopic and mesopic conditions with and without a glare source approximately 1 month after surgery using the Contrast Sensitivity Accurate Tester (Menicon CAT-2000). The mean mesopic contrast visual acuity at moderate- to low-contrast visual targets was significantly worse in the presence of a glare source in both groups, whereas photopic contrast visual acuity did not change significantly. There were no significant differences between the 2 groups in the mean visual acuity or in photopic or mesopic lighting contrast visual acuity with and without a glare source. Furthermore, there was no significant difference in loss of contrast visual acuity in the presence of glare. Mesopic contrast sensitivity with both acrylic IOLs was impaired significantly in the presence of glare, but the impairment of contrast sensitivity from glare was approximately the same between eyes with a textured-edge IOL and eyes with a round-anterior, sloped-sided edge IOL.

  6. Visual function at altitude under night vision assisted conditions.

    PubMed

    Vecchi, Diego; Morgagni, Fabio; Guadagno, Anton G; Lucertini, Marco

    2014-01-01

    Hypoxia, even mild, is known to produce negative effects on visual function, including decreased visual acuity and sensitivity to contrast, mostly in low light. This is of special concern when night vision devices (NVDs) are used during flight because they also provide poor images in terms of resolution and contrast. While wearing NVDs in low light conditions, 16 healthy male aviators were exposed to a simulated altitude of 12,500 ft in a hypobaric chamber. Snellen visual acuity decreased in normal light from 28.5 +/- 4.2/20 (normoxia) to 37.2 +/- 7.4/20 (hypoxia) and, in low light, from 33.8 +/- 6.1/20 (normoxia) to 42.2 +/- 8.4/20 (hypoxia), both at a significant level. An association was found between blood oxygen saturation and visual acuity without significance. No changes occurred in terms of sensitivity to contrast. Our data demonstrate that mild hypoxia is capable of affecting visual acuity and the photopic/high mesopic range of NVD-aided vision. This may be due to several reasons, including the sensitivity to hypoxia of photoreceptors and other retinal cells. Contrast sensitivity is possibly preserved under NVD-aided vision due to its dependency on the goggles' gain.

  7. Structural and functional photoacoustic molecular tomography aided by emerging contrast agents

    PubMed Central

    Nie, Liming

    2015-01-01

    Photoacoustic tomography (PAT) can offer structural, functional and molecular contrasts at scalable observation level. By ultrasonically overcoming the strong optical scattering, this imaging technology can reach centimeters penetration depth while retaining high spatial resolution in biological tissue. Recent extensive research has been focused on developing new contrast agents to improve the imaging sensitivity, specificity and efficiency. These emerging materials have substantially accelerated PAT applications in signal sensing, functional imaging, biomarker labeling and therapy monitoring etc. Here, the potentials of different optical probes as PAT contrast agents were elucidated. We first describe the instrumental embodiments and the measured functional parameters, then focus on emerging contrast agent-based PAT applications, and finally discuss the challenges and prospects. PMID:24967718

  8. Towards an Analytical Age-Dependent Model of Contrast Sensitivity Functions for an Ageing Society

    PubMed Central

    Joulan, Karine; Brémond, Roland

    2015-01-01

    The Contrast Sensitivity Function (CSF) describes how the visibility of a grating depends on the stimulus spatial frequency. Many published CSF data have demonstrated that contrast sensitivity declines with age. However, an age-dependent analytical model of the CSF is not available to date. In this paper, we propose such an analytical CSF model based on visual mechanisms, taking into account the age factor. To this end, we have extended an existing model from Barten (1999), taking into account the dependencies of this model's optical and physiological parameters on age. Age-dependent models of the cones and ganglion cells densities, the optical and neural MTF, and optical and neural noise are proposed, based on published data. The proposed age-dependent CSF is finally tested against available experimental data, with fair results. Such an age-dependent model may be beneficial when designing real-time age-dependent image coding and display applications. PMID:26078994

  9. Differential effects of exogenous and endogenous attention on second-order texture contrast sensitivity

    PubMed Central

    Barbot, Antoine; Landy, Michael S.; Carrasco, Marisa

    2012-01-01

    The visual system can use a rich variety of contours to segment visual scenes into distinct perceptually coherent regions. However, successfully segmenting an image is a computationally expensive process. Previously we have shown that exogenous attention—the more automatic, stimulus-driven component of spatial attention—helps extract contours by enhancing contrast sensitivity for second-order, texture-defined patterns at the attended location, while reducing sensitivity at unattended locations, relative to a neutral condition. Interestingly, the effects of exogenous attention depended on the second-order spatial frequency of the stimulus. At parafoveal locations, attention enhanced second-order contrast sensitivity to relatively high, but not to low second-order spatial frequencies. In the present study we investigated whether endogenous attention—the more voluntary, conceptually-driven component of spatial attention—affects second-order contrast sensitivity, and if so, whether its effects are similar to those of exogenous attention. To that end, we compared the effects of exogenous and endogenous attention on the sensitivity to second-order, orientation-defined, texture patterns of either high or low second-order spatial frequencies. The results show that, like exogenous attention, endogenous attention enhances second-order contrast sensitivity at the attended location and reduces it at unattended locations. However, whereas the effects of exogenous attention are a function of the second-order spatial frequency content, endogenous attention affected second-order contrast sensitivity independent of the second-order spatial frequency content. This finding supports the notion that both exogenous and endogenous attention can affect second-order contrast sensitivity, but that endogenous attention is more flexible, benefitting performance under different conditions. PMID:22895879

  10. Sensory Contributions to Impaired Emotion Processing in Schizophrenia

    PubMed Central

    Butler, Pamela D.; Abeles, Ilana Y.; Weiskopf, Nicole G.; Tambini, Arielle; Jalbrzikowski, Maria; Legatt, Michael E.; Zemon, Vance; Loughead, James; Gur, Ruben C.; Javitt, Daniel C.

    2009-01-01

    Both emotion and visual processing deficits are documented in schizophrenia, and preferential magnocellular visual pathway dysfunction has been reported in several studies. This study examined the contribution to emotion-processing deficits of magnocellular and parvocellular visual pathway function, based on stimulus properties and shape of contrast response functions. Experiment 1 examined the relationship between contrast sensitivity to magnocellular- and parvocellular-biased stimuli and emotion recognition using the Penn Emotion Recognition (ER-40) and Emotion Differentiation (EMODIFF) tests. Experiment 2 altered the contrast levels of the faces themselves to determine whether emotion detection curves would show a pattern characteristic of magnocellular neurons and whether patients would show a deficit in performance related to early sensory processing stages. Results for experiment 1 showed that patients had impaired emotion processing and a preferential magnocellular deficit on the contrast sensitivity task. Greater deficits in ER-40 and EMODIFF performance correlated with impaired contrast sensitivity to the magnocellular-biased condition, which remained significant for the EMODIFF task even when nonspecific correlations due to group were considered in a step-wise regression. Experiment 2 showed contrast response functions indicative of magnocellular processing for both groups, with patients showing impaired performance. Impaired emotion identification on this task was also correlated with magnocellular-biased visual sensory processing dysfunction. These results provide evidence for a contribution of impaired early-stage visual processing in emotion recognition deficits in schizophrenia and suggest that a bottom-up approach to remediation may be effective. PMID:19793797

  11. Sensory contributions to impaired emotion processing in schizophrenia.

    PubMed

    Butler, Pamela D; Abeles, Ilana Y; Weiskopf, Nicole G; Tambini, Arielle; Jalbrzikowski, Maria; Legatt, Michael E; Zemon, Vance; Loughead, James; Gur, Ruben C; Javitt, Daniel C

    2009-11-01

    Both emotion and visual processing deficits are documented in schizophrenia, and preferential magnocellular visual pathway dysfunction has been reported in several studies. This study examined the contribution to emotion-processing deficits of magnocellular and parvocellular visual pathway function, based on stimulus properties and shape of contrast response functions. Experiment 1 examined the relationship between contrast sensitivity to magnocellular- and parvocellular-biased stimuli and emotion recognition using the Penn Emotion Recognition (ER-40) and Emotion Differentiation (EMODIFF) tests. Experiment 2 altered the contrast levels of the faces themselves to determine whether emotion detection curves would show a pattern characteristic of magnocellular neurons and whether patients would show a deficit in performance related to early sensory processing stages. Results for experiment 1 showed that patients had impaired emotion processing and a preferential magnocellular deficit on the contrast sensitivity task. Greater deficits in ER-40 and EMODIFF performance correlated with impaired contrast sensitivity to the magnocellular-biased condition, which remained significant for the EMODIFF task even when nonspecific correlations due to group were considered in a step-wise regression. Experiment 2 showed contrast response functions indicative of magnocellular processing for both groups, with patients showing impaired performance. Impaired emotion identification on this task was also correlated with magnocellular-biased visual sensory processing dysfunction. These results provide evidence for a contribution of impaired early-stage visual processing in emotion recognition deficits in schizophrenia and suggest that a bottom-up approach to remediation may be effective.

  12. Visual evoked potential measurement of contrast sensitivity in a case of retinal laser injury reveals visual function loss despite normal acuity

    NASA Astrophysics Data System (ADS)

    Glickman, Randolph D.; Harrison, Joseph M.; Zwick, Harry; Longbotham, Harold G.; Ballentine, Charles S.; Pierce, Bennie

    1996-04-01

    Although visual function following retinal laser injuries has traditionally been assessed by measuring visual acuity, this measure only indicates the highest spatial frequency resolvable under high-contrast viewing conditions. Another visual psychophysical parameter is contrast sensitivity (CS), which measures the minimum contrast required for detection of targets over a range of spatial frequencies, and may evaluate visual mechanisms that do not directly subserve acuity. We used the visual evoked potential (VEP) to measure CS in a population of normal subjects and in patients with ophthalmic conditions affecting retinal function, including one patient with a laser injury in the macula. In this patient, the acuity had recovered from

  13. Toxic risks and nutritional benefits of traditional diet on near visual contrast sensitivity and color vision in the Brazilian Amazon.

    PubMed

    Fillion, Myriam; Lemire, Mélanie; Philibert, Aline; Frenette, Benoît; Weiler, Hope Alberta; Deguire, Jason Robert; Guimarães, Jean Remy Davée; Larribe, Fabrice; Barbosa, Fernando; Mergler, Donna

    2013-07-01

    Visual functions are known to be sensitive to toxins such as mercury (Hg) and lead (Pb), while omega-3 fatty acids (FA) and selenium (Se) may be protective. In the Tapajós region of the Brazilian Amazon, all of these elements are present in the local diet. Examine how near visual contrast sensitivity and acquired color vision loss vary with biomarkers of toxic exposures (Hg and Pb) and the nutrients Se and omega-3 FA in riverside communities of the Tapajós. Complete visuo-ocular examinations were performed. Near visual contrast sensitivity and color vision were assessed in 228 participants (≥15 years) without diagnosed age-related cataracts or ocular pathologies and with near visual acuity refracted to at least 20/40. Biomarkers of Hg (hair), Pb (blood), Se (plasma), and the omega-3 FAs eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA) in plasma phospholipids were measured. Multiple linear regressions were used to examine the relations between visual outcomes and biomarkers, taking into account age, sex, drinking and smoking. Reduced contrast sensitivity at all spatial frequencies was associated with hair Hg, while %EPA, and to a lesser extent %EPA+DHA, were associated with better visual function. The intermediate spatial frequency of contrast sensitivity (12 cycles/degree) was negatively related to blood Pb and positively associated with plasma Se. Acquired color vision loss increased with hair Hg and decreased with plasma Se and %EPA. These findings suggest that the local diet of riverside communities of the Amazon contain toxic substances that can have deleterious effects on vision as well as nutrients that are beneficial for visual function. Since remediation at the source is a long process, a better knowledge of the nutrient content and health effects of traditional foods would be useful to minimize harmful effects of Hg and Pb exposure. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Assessment of contrast gain signature in inferred magnocellular and parvocellular pathways in patients with glaucoma

    PubMed Central

    Sun, Hao; Swanson, William H.; Arvidson, Brian; Dul, Mitchell W.

    2010-01-01

    PURPOSE Contrast gain signatures of inferred magnocellular and parvocellular postreceptoral pathways were assessed for patients with glaucoma using a contrast discrimination paradigm developed by Pokorny and Smith. The potential causes for changes in contrast gain signature were investigated using model simulations of ganglion cell contrast responses. METHODS Foveal contrast discrimination thresholds were measured with a pedestal-Δ-pedestal paradigm developed by Pokorny and Smith (1997). Stimuli were 27 msec luminance increments superimposed on 227 msec pulsed Δ-pedestals. Contrast thresholds and contrast gain signatures mediated by the inferred magnocellular (MC) and parvocellular (PC) pathways were assessed using linear fits to contrast discrimination thresholds at either lower or higher Δ-pedestal contrasts, respectively. Twenty-seven patients with glaucoma were tested, as well as 16 age-similar control subjects free of eye disease. RESULTS Contrast sensitivity and contrast gain signature mediated by the inferred MC pathway were lower for the glaucoma group, and reduced contrast gain signature was correlated with reduced contrast sensitivity (r2=45%, p<0.0005). These two parameters mediated by the inferred PC pathway were little affected for the glaucoma group. Model simulations suggest that the reduced contrast sensitivity and contrast gain signature were consistent with the hypothesis that reduced MC ganglion cell dendritic complexity can lead to reduced effective retinal illuminance, and hence increased semi-saturation contrast of the ganglion cell contrast response functions. CONCLUSIONS The contrast sensitivity and contrast gain signature of the inferred MC pathway were reduced in patients with glaucoma. The results were consistent with a model of ganglion cell dysfunction due to reduced synaptic density. PMID:18501947

  15. Hyperpolarized Gas MRI: Technique and Applications

    PubMed Central

    McAdams, Holman P.; Kaushik, S. Sivaram; Driehuys, Bastiaan

    2015-01-01

    Synopsis Functional imaging today offers a rich world of information that is more sensitive to changes in lung structure and function than traditionally obtained pulmonary function tests. Hyperpolarized helium (3He) and xenon (129Xe) MR imaging of the lungs provided new sensitive contrast mechanisms to probe changes in pulmonary ventilation, microstructure and gas exchange. With the recent scarcity in the supply of 3He the field of hyperpolarized gas imaging shifted to the use of cheaper and naturally available 129Xe. Xenon is well tolerated and recent technical advances have ensured that the 129Xe image quality is on par with that of 3He. The added advantage of 129Xe is its solubility in pulmonary tissue, which allows exploring specific lung function characteristics involved in gas exchange and alveolar oxygenation. With a plethora of contrast mechanisms, hyperpolarized gases and 129Xe in particular, stands to be an excellent probe of pulmonary structure and function, and provide sensitive and non-invasive biomarkers for a wide variety of pulmonary diseases. PMID:25952516

  16. Training in Contrast Detection Improves Motion Perception of Sinewave Gratings in Amblyopia

    PubMed Central

    Hou, Fang; Huang, Chang-bing; Tao, Liming; Feng, Lixia; Zhou, Yifeng; Lu, Zhong-Lin

    2011-01-01

    Purpose. One critical concern about using perceptual learning to treat amblyopia is whether training with one particular stimulus and task generalizes to other stimuli and tasks. In the spatial domain, it has been found that the bandwidth of contrast sensitivity improvement is much broader in amblyopes than in normals. Because previous studies suggested the local motion deficits in amblyopia are explained by the spatial vision deficits, the hypothesis for this study was that training in the spatial domain could benefit motion perception of sinewave gratings. Methods. Nine adult amblyopes (mean age, 22.1 ± 5.6 years) were trained in a contrast detection task in the amblyopic eye for 10 days. Visual acuity, spatial contrast sensitivity functions, and temporal modulation transfer functions (MTF) for sinewave motion detection and discrimination were measured for each eye before and after training. Eight adult amblyopes (mean age, 22.6 ± 6.7 years) served as control subjects. Results. In the amblyopic eye, training improved (1) contrast sensitivity by 6.6 dB (or 113.8%) across spatial frequencies, with a bandwidth of 4.4 octaves; (2) sensitivity of motion detection and discrimination by 3.2 dB (or 44.5%) and 3.7 dB (or 53.1%) across temporal frequencies, with bandwidths of 3.9 and 3.1 octaves, respectively; (3) visual acuity by 3.2 dB (or 44.5%). The fellow eye also showed a small amount of improvement in contrast sensitivities and no significant change in motion perception. Control subjects who received no training demonstrated no obvious improvement in any measure. Conclusions. The results demonstrate substantial plasticity in the amblyopic visual system, and provide additional empirical support for perceptual learning as a potential treatment for amblyopia. PMID:21693615

  17. [Mechanism underlying spatial vision deficit of monocular amblyopia based on the theory of Magnocellular and Parvocellular (M-P) pathways].

    PubMed

    Song, Feng-wei; Sun, Zhao-hui; Yang, Yi; Wang, Li-ping; Tang, Xia-jing; Chen, Bin-bin; Yu, Xiao-ning

    2014-01-01

    To investigate the relationship between the characteristics of spatial vision deficit and the degree of amblyopia in monocular amblyopes, and to analyze its mechanism with the theory of Magnocellular and Parvocellular pathways. One hundred and eleven patients with monocular amblyopes aged 7-34 were included in this study. Distance best corrected visual acuity (BCVA) in logMAR units and contrast sensitivity function test were performed on both eyes in all patients with ETDRS digital visual chart and functional test system OPTECR 6500. The spatial vision of amblyopic and non-amblyopic eyes was evaluated by the AULCSF, Smax, Frmax and cutSF derived from the curve of contrast sensitivity function. The degree of amblyopia was significantly correlated with the difference of AULCSF between the amblyopic and non-amblyopia eyes (r=-0.83, P<0.01). BCVA of amblyopic eyes was significantly correlated with AULCSF, CutSF, Smax, Frmax(r=-0.68, -0.80, -0.73, -0.56, respectively; P<0.01). In amblyopic eyes, significant difference in BCVA, AULCSF, Smax, Frmax and CutSF was seen among different amblyopic groups (P<0.01), which was defined by the degree of amblyopia. In non-amblyopic eyes,no significant difference in BCVA, AULCSF, Smax, Frmax and CutSF was noted among different amblyopic groups (P>0.05). In mild amblyopes, no significant difference in AULCSF and Frmax was found between the amblyopic eyes and non-amblyopic eyes (P>0.05), while Smax and CutSF were significantly different. However, in moderate and severe amblyopes, significant differences in BCVA, AULCSF, Smax, Frmax and CutSF was seen between the amblyopic and non-amblyopic eyes (P<0.01). In amblyopic eyes, significant difference in contrast sensitivity was noted in all kinds of spatial frequencies among different amblyopic groups (P<0.01), and in non-amblyopic eyes, significant differences in contrast sensitivity was not seen in all kinds of spatial frequencies among different amblyopic groups. The AULCSF, CutSF, Smax and Frmax are accorded with visual acuity for evaluation of the spatial vision of amblyopia. As the severity of amblyopia increases, the overall function of spatial vision in amblyopic eyes gradually decreases, the resolution ability of high spatial frequency is gradually weaken, the peak of contrast detection function gradually descends, and the optimal spatial frequency for contrast detection offsets toward low level of spatial frequency. Mild monocular amblyopia produces spatial contrast sensitivity loss in high spatial vision, suggesting there may be decreased sensitivity of the Parvocellular pathway, and no significant anomalous processing of Magnocellular Pathway. Whereas, in moderate and severe amblyopes, a generalized loss of sensitivity is observed at each spatial frequency. This result shows that both Magnocellular and Parvocellular pathways are damaged in different degrees, especially in Parvocellular pathway.

  18. Assessment of contrast gain signature in inferred magnocellular and parvocellular pathways in patients with glaucoma.

    PubMed

    Sun, Hao; Swanson, William H; Arvidson, Brian; Dul, Mitchell W

    2008-11-01

    Contrast gain signatures of inferred magnocellular and parvocellular postreceptoral pathways were assessed for patients with glaucoma using a contrast discrimination paradigm developed by Pokorny and Smith. The potential causes for changes in contrast gain signature were investigated using model simulations of ganglion cell contrast responses. Foveal contrast discrimination thresholds were measured with a pedestal-Delta-pedestal paradigm developed by Pokorny and Smith [Pokorny, J., & Smith, V. C. (1997). Psychophysical signatures associated with magnocellular and parvocellular pathway contrast gain. Journal of the Optical Society of America A, 14(9), 2477-2486]. Stimuli were 27 ms luminance increments superimposed on 227 ms pulsed Delta-pedestals. Contrast thresholds and contrast gain signatures mediated by the inferred magnocellular (MC) and parvocellular (PC) pathways were assessed using linear fits to contrast discrimination thresholds at either lower or higher Delta-pedestal contrasts, respectively. Twenty-seven patients with glaucoma were tested, as well as 16 age-similar control subjects free of eye disease. Contrast sensitivity and contrast gain signature mediated by the inferred MC pathway were lower for the glaucoma group, and reduced contrast gain signature was correlated with reduced contrast sensitivity (r(2)=45%, p<.0005). These two parameters mediated by the inferred PC pathway were little affected for the glaucoma group. Model simulations suggest that the reduced contrast sensitivity and contrast gain signature were consistent with the hypothesis that reduced MC ganglion cell dendritic complexity can lead to reduced effective retinal illuminance, and hence increased semi-saturation contrast of the ganglion cell contrast response functions. The contrast sensitivity and contrast gain signature of the inferred MC pathway were reduced in patients with glaucoma. The results were consistent with a model of ganglion cell dysfunction due to reduced synaptic density.

  19. A gaze-contingent display to study contrast sensitivity under natural viewing conditions

    NASA Astrophysics Data System (ADS)

    Dorr, Michael; Bex, Peter J.

    2011-03-01

    Contrast sensitivity has been extensively studied over the last decades and there are well-established models of early vision that were derived by presenting the visual system with synthetic stimuli such as sine-wave gratings near threshold contrasts. Natural scenes, however, contain a much wider distribution of orientations, spatial frequencies, and both luminance and contrast values. Furthermore, humans typically move their eyes two to three times per second under natural viewing conditions, but most laboratory experiments require subjects to maintain central fixation. We here describe a gaze-contingent display capable of performing real-time contrast modulations of video in retinal coordinates, thus allowing us to study contrast sensitivity when dynamically viewing dynamic scenes. Our system is based on a Laplacian pyramid for each frame that efficiently represents individual frequency bands. Each output pixel is then computed as a locally weighted sum of pyramid levels to introduce local contrast changes as a function of gaze. Our GPU implementation achieves real-time performance with more than 100 fps on high-resolution video (1920 by 1080 pixels) and a synthesis latency of only 1.5ms. Psychophysical data show that contrast sensitivity is greatly decreased in natural videos and under dynamic viewing conditions. Synthetic stimuli therefore only poorly characterize natural vision.

  20. [Research on Residual Aberrations Correction with Adaptive Optics Technique in Patients Undergoing Orthokeratology].

    PubMed

    Gong, Rui; Yang, Bi; Liu, Longqian; Dai, Yun; Zhang, Yudong; Zhao, Haoxin

    2016-06-01

    We conducted this study to explore the influence of the ocular residual aberrations changes on contrast sensitivity(CS)function in eyes undergoing orthokeratology using adaptive optics technique.Nineteen subjects’ nineteen eyes were included in this study.The subjects were between 12 and 20years(14.27±2.23years)of age.An adaptive optics(AO)system was adopted to measure and compensate the residual aberrations through a 4-mm artificial pupil,and at the same time the contrast sensitivities were measured at five spatial frequencies(2,4,8,16,and 32 cycles per degree).The CS measurements with and without AO correction were completed.The sequence of the measurements with and without AO correction was randomly arranged without informing the observers.A two-interval forced-choice procedure was used for the CS measurements.The paired t-test was used to compare the contrast sensitivity with and without AO correction at each spatial frequency.The results revealed that the AO system decreased the mean total root mean square(RMS)from 0.356μm to 0.160μm(t=10.517,P<0.001),and the mean total higher-order RMS from 0.246μm to 0.095μm(t=10.113,P<0.001).The difference in log contrast sensitivity with and without AO correction was significant only at 8cpd(t=-2.51,P=0.02).Thereby we concluded that correcting the ocular residual aberrations using adaptive optics technique could improve the contrast sensitivity function at intermediate spatial frequency in patients undergoing orthokeratology.

  1. A comprehensive assessment of visual impairment in a population of older Americans. The SEE Study. Salisbury Eye Evaluation Project.

    PubMed

    Rubin, G S; West, S K; Muñoz, B; Bandeen-Roche, K; Zeger, S; Schein, O; Fried, L P

    1997-03-01

    The Salisbury Eye Evaluation Project is a longitudinal study of risk factors for age-related eye diseases and the impact of eye disease and visual impairment on physical disability. In this article, the authors report the prevalence of visual impairment in their population and explore the relations among the various measures of visual function. A population-based sample of 2520 residents of Salisbury, Maryland, between the ages of 65 and 84 years were enrolled in the study. Twenty-six percent of participants were black. Vision tests included best-corrected Early Treatment Diabetic Retinopathy Study acuity, Pelli-Robson contrast sensitivity with and without glare, Randot stereoacuity, and 60 degrees Humphrey visual fields. Visual function decreased linearly with age for the acuity, contrast sensitivity, glare, and visual field tests. Stereoacuity remained constant into the mid-70s and declined at an accelerating rate thereafter. Black participants had lower contrast sensitivity, reduced stereoacuity, and worse visual fields, at all ages compared to white participants; however, white participants were more sensitive to glare. The overall prevalence of visual acuity impairment in blacks was 5.6% versus 3.0% for whites, using the traditional United States definition (worse than 20/40 to better than 20/200) and 3.3% for blacks versus 1.6% for whites, using the World Health Organization definition (worse than 20/60 to 20/400). Acuity was correlated moderately with contrast sensitivity, stereoacuity, and visual fields (Spearman rho = 0.50, 0.35, and 0.34, respectively). The correlation between acuity and glare sensitivity was low (rho = 0.12). Many aspects of visual function, not just acuity, decline with age. Black participants have more visual impairement than do white participants for all tests except glare sensitivity. The prevalence of visual acuity impairement in the Salisbury Eye Evaluation population is lower than that reported by other studies using similar test procedures. Low-to-moderate correlations among vision test scores suggest that several different dimensions of visual function are being assessed.

  2. VISUAL CONTRAST SENSITIVITY: A SENSITIVE INDICATOR OF NEUROTOXICITY FOR RISK ASSESSMENT AND CLINICAL APPLICATIONS.

    EPA Science Inventory

    Both human-health risk assessments of adverse effects from chronic, environmental exposures to neurotoxics and clinical practice are in need of objective indicators sensitive to the early stages of disruption in neurologic function; risk assessment for the purposes of hazard iden...

  3. Psychophysical contrast calibration

    PubMed Central

    To, Long; Woods, Russell L; Goldstein, Robert B; Peli, Eli

    2013-01-01

    Electronic displays and computer systems offer numerous advantages for clinical vision testing. Laboratory and clinical measurements of various functions and in particular of (letter) contrast sensitivity require accurately calibrated display contrast. In the laboratory this is achieved using expensive light meters. We developed and evaluated a novel method that uses only psychophysical responses of a person with normal vision to calibrate the luminance contrast of displays for experimental and clinical applications. Our method combines psychophysical techniques (1) for detection (and thus elimination or reduction) of display saturating nonlinearities; (2) for luminance (gamma function) estimation and linearization without use of a photometer; and (3) to measure without a photometer the luminance ratios of the display’s three color channels that are used in a bit-stealing procedure to expand the luminance resolution of the display. Using a photometer we verified that the calibration achieved with this procedure is accurate for both LCD and CRT displays enabling testing of letter contrast sensitivity to 0.5%. Our visual calibration procedure enables clinical, internet and home implementation and calibration verification of electronic contrast testing. PMID:23643843

  4. Visual Contrast Sensitivity Improvement by Right Frontal High-Beta Activity Is Mediated by Contrast Gain Mechanisms and Influenced by Fronto-Parietal White Matter Microstructure

    PubMed Central

    Quentin, Romain; Elkin Frankston, Seth; Vernet, Marine; Toba, Monica N.; Bartolomeo, Paolo; Chanes, Lorena; Valero-Cabré, Antoni

    2016-01-01

    Behavioral and electrophysiological studies in humans and non-human primates have correlated frontal high-beta activity with the orienting of endogenous attention and shown the ability of the latter function to modulate visual performance. We here combined rhythmic transcranial magnetic stimulation (TMS) and diffusion imaging to study the relation between frontal oscillatory activity and visual performance, and we associated these phenomena to a specific set of white matter pathways that in humans subtend attentional processes. High-beta rhythmic activity on the right frontal eye field (FEF) was induced with TMS and its causal effects on a contrast sensitivity function were recorded to explore its ability to improve visual detection performance across different stimulus contrast levels. Our results show that frequency-specific activity patterns engaged in the right FEF have the ability to induce a leftward shift of the psychometric function. This increase in visual performance across different levels of stimulus contrast is likely mediated by a contrast gain mechanism. Interestingly, microstructural measures of white matter connectivity suggest a strong implication of right fronto-parietal connectivity linking the FEF and the intraparietal sulcus in propagating high-beta rhythmic signals across brain networks and subtending top-down frontal influences on visual performance. PMID:25899709

  5. Application of a Noise Adaptive Contrast Sensitivity Function to Image Data Compression

    NASA Astrophysics Data System (ADS)

    Daly, Scott J.

    1989-08-01

    The visual contrast sensitivity function (CSF) has found increasing use in image compression as new algorithms optimize the display-observer interface in order to reduce the bit rate and increase the perceived image quality. In most compression algorithms, increasing the quantization intervals reduces the bit rate at the expense of introducing more quantization error, a potential image quality degradation. The CSF can be used to distribute this error as a function of spatial frequency such that it is undetectable by the human observer. Thus, instead of being mathematically lossless, the compression algorithm can be designed to be visually lossless, with the advantage of a significantly reduced bit rate. However, the CSF is strongly affected by image noise, changing in both shape and peak sensitivity. This work describes a model of the CSF that includes these changes as a function of image noise level by using the concepts of internal visual noise, and tests this model in the context of image compression with an observer study.

  6. Psychophysical and perceptual performance in a simulated-scotoma model of human eye injury

    NASA Astrophysics Data System (ADS)

    Brandeis, R.; Egoz, I.; Peri, D.; Sapiens, N.; Turetz, J.

    2008-02-01

    Macular scotomas, affecting visual functioning, characterize many eye and neurological diseases like AMD, diabetes mellitus, multiple sclerosis, and macular hole. In this work, foveal visual field defects were modeled, and their effects were evaluated on spatial contrast sensitivity and a task of stimulus detection and aiming. The modeled occluding scotomas, of different size, were superimposed on the stimuli presented on the computer display, and were stabilized on the retina using a mono Purkinje Eye-Tracker. Spatial contrast sensitivity was evaluated using square-wave grating stimuli, whose contrast thresholds were measured using the method of constant stimuli with "catch trials". The detection task consisted of a triple conjunctive visual search display of: size (in visual angle), contrast and background (simple, low-level features vs. complex, high-level features). Search/aiming accuracy as well as R.T. measures used for performance evaluation. Artificially generated scotomas suppressed spatial contrast sensitivity in a size dependent manner, similar to previous studies. Deprivation effect was dependent on spatial frequency, consistent with retinal inhomogeneity models. Stimulus detection time was slowed in complex background search situation more than in simple background. Detection speed was dependent on scotoma size and size of stimulus. In contrast, visually guided aiming was more sensitive to scotoma effect in simple background search situation than in complex background. Both stimulus aiming R.T. and accuracy (precision targeting) were impaired, as a function of scotoma size and size of stimulus. The data can be explained by models distinguishing between saliency-based, parallel and serial search processes, guiding visual attention, which are supported by underlying retinal as well as neural mechanisms.

  7. A novel apparatus for interocular interaction evaluation in children with and without anisometropic amblyopia.

    PubMed

    Lai, Xin Jie Angela; Alexander, Jack; He, Ming Guang; Yang, Zhi Kuan; Suttle, Catherine

    2012-07-01

    Dichoptic visual stimulation may be achieved using shutter goggles and mirror systems. These methods vary in their feasibility for use in children. This study aims to investigate the feasibility of use of a simple trial frame-based system to evaluate interactions in children. Low contrast acuity, contrast sensitivity and alignment sensitivity were measured in the non-dominant eye of 10 normally-sighted children, 14 anisometropic children without amblyopia and 14 anisometropic amblyopic children (aged 5-11 years) using goggles and a trial frame apparatus (TFA). The dominant eye was either fully or partially occluded. The difference in visual functions in the non-dominant eye between the full and partial occlusion conditions was termed the 'interaction index'. Agreement between the TFA and goggles in terms of visual functions and interactions was assessed in anisometropic children with and without amblyopia using the Bland-Altman method and t-test. Training sessions allowed subjects to become accustomed to the systems and tasks. The duration of training, the number of breaks requested by subjects and their willingness to attend further experiments were recorded in 10 subjects from each group and were compared between groups and between systems. Both Bland-Altman and t-test methods indicated acceptable agreement between the TFA and goggles in visual function and interaction measures (p > 0.05), except for contrast sensitivity measured in anisometropic children without amblyopia (p = 0.042). For all subject groups, contrast sensitivity training was significantly longer using goggles than using the TFA (p ≤ 0.001). Significantly more breaks were requested in acuity and contrast sensitivity testing, when goggles were used than when the TFA was used (p < 0.045). Anisometropic children without amblyopia showed a significantly greater willingness to attend more experiments using the TFA than using goggles (p = 0.025). The TFA may be a useful tool in studies of interactions in amblyopes, particularly in studies of children's vision. © 2012 The Authors. Clinical and Experimental Optometry © 2012 Optometrists Association Australia.

  8. Visual function of police officers who have undergone refractive surgery.

    PubMed

    Hovis, Jeffery K; Ramaswamy, Shankaran

    2006-11-01

    The visual acuity and contrast sensitivity of police recruits and officers was evaluated in both normal and dim illumination conditions to determine whether officers who have had refractive surgery have compromised night vision. The control group consisted of 76 officers and recruits who have not had refractive surgery and the refractive surgery group consisted of 22 officers and recruits who had refractive surgery. Visual acuity and contrast sensitivity were measured under both room illumination and dim illumination. The room illumination test series included high contrast acuity, low contrast acuity and Pelli-Robson contrast sensitivity. The dim illumination test series included high contrast acuity, low contrast acuity, Pelli-Robson contrast sensitivity, license plate number acuity (with and without glare) and the Mesotest. The general findings were that the refractive surgery group had lower acuity scores on low contrast targets in both room and dim light levels along with a reduction in the Mesotest scores with a glare source compared to the control group. Although refractive surgery police recruits and officers had reduced performance on some vision tests, these reductions were small and it is unlikely that their performance on vision related tasks would be compromised, on average. The major concern is the small number of refractive surgery candidates whose results were well outside the range of the non-surgical candidates. Their vision may be unacceptable for policing. Copyright (c) 2006 Wiley-Liss, Inc.

  9. High sensitivity contrast enhanced optical coherence tomography for functional in vivo imaging

    NASA Astrophysics Data System (ADS)

    Liba, Orly; SoRelle, Elliott D.; Sen, Debasish; de la Zerda, Adam

    2017-02-01

    In this study, we developed and applied highly-scattering large gold nanorods (LGNRs) and custom spectral detection algorithms for high sensitivity contrast-enhanced optical coherence tomography (OCT). We were able to detect LGNRs at a concentration as low as 50 pM in blood. We used this approach for noninvasive 3D imaging of blood vessels deep in solid tumors in living mice. Additionally, we demonstrated multiplexed imaging of spectrally-distinct LGNRs that enabled observations of functional drainage in lymphatic networks. This method, which we call MOZART, provides a platform for molecular imaging and characterization of tissue noninvasively at cellular resolution.

  10. Chromatic and achromatic visual fields in relation to choroidal thickness in patients with high myopia: A pilot study.

    PubMed

    García-Domene, M C; Luque, M J; Díez-Ajenjo, M A; Desco-Esteban, M C; Artigas, J M

    2018-02-01

    To analyse the relationship between the choroidal thickness and the visual perception of patients with high myopia but without retinal damage. All patients underwent ophthalmic evaluation including a slit lamp examination and dilated ophthalmoscopy, subjective refraction, best corrected visual acuity, axial length, optical coherence tomography, contrast sensitivity function and sensitivity of the visual pathways. We included eleven eyes of subjects with high myopia. There are statistical correlations between choroidal thickness and almost all the contrast sensitivity values. The sensitivity of magnocellular and koniocellular pathways is the most affected, and the homogeneity of the sensibility of the magnocellular pathway depends on the choroidal thickness; when the thickness decreases, the sensitivity impairment extends from the center to the periphery of the visual field. Patients with high myopia without any fundus changes have visual impairments. We have found that choroidal thickness correlates with perceptual parameters such as contrast sensitivity or mean defect and pattern standard deviation of the visual fields of some visual pathways. Our study shows that the magnocellular and koniocellular pathways are the most affected, so that these patients have impairment in motion perception and blue-yellow contrast perception. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  11. Vitrectomy for floaters: prospective efficacy analyses and retrospective safety profile.

    PubMed

    Sebag, Jerry; Yee, Kenneth M P; Wa, Christianne A; Huang, Laura C; Sadun, Alfredo A

    2014-06-01

    Floaters impact vision but the mechanism is unknown. We hypothesize that floaters reduce contrast sensitivity function, which can be normalized by vitrectomy, and that minimally invasive vitrectomy will have lower incidences of retinal tears (reported at 30%) and cataracts (50-76%). Seventy-six eyes (34 phakic) with floaters were evaluated in 2 separate studies. Floater etiologies were primarily posterior vitreous detachment in 61 of 76 eyes (80%) and myopic vitreopathy in 24 of 76 eyes (32%). Minimally invasive 25G vitrectomy was performed without posterior vitreous detachment induction, leaving anterior vitreous, and using nonhollow probes for cannula extraction. Efficacy was studied prospectively (up to 9 months) in 16 floater cases with Freiburg Acuity Contrast Testing (Weber index [%W] reproducibility = 92.1%) and the National Eye Institute Visual Function Questionnaire. Safety was separately evaluated in 60 other cases followed up on an average of 17.5 months (range, 3-51 months). Floater eyes had 67% contrast sensitivity function attenuation (4.0 ± 2.3 %W; control subjects = 2.4 ± 0.9 %W, P < 0.013). After vitrectomy, contrast sensitivity function normalized in each case at 1 week (2.0 ± 1.4 %W, P < 0.01) and remained normal at 1 month (2.0 ± 1.0 %W, P < 0.003) and 3 months to 9 months (2.2 ± 1.5 %W, P < 0.018). Visual Function Questionnaire was 28.3% lower in floater patients (73.2 ± 15.6, N = 16) than in age-matched control subjects (93.9 ± 8.0, N = 12, P < 0.001), and postoperatively improved by 29.2% (P < 0.001). In the safety study of 60 floater cases treated with vitrectomy, none developed retinal breaks, infection, or glaucoma after a mean follow-up of 17.5 months. Only 8 of 34 cases (23.5%) required cataract surgery (none younger than 53 years) at an average of 15 months postvitrectomy. Floaters lower contrast sensitivity function, which normalizes after vitrectomy. Visual Function Questionnaire quantified improvement in satisfaction. Not inducing posterior vitreous detachment reduced retinal tear incidence from 30% to 0% (P < 0.007). Postvitrectomy cataract incidence was reduced from 50% to 23.5% (P < 0.02). This approach thus seems effective and safe in alleviating the visual dysfunction induced by floaters.

  12. Measurement of visual contrast sensitivity

    NASA Astrophysics Data System (ADS)

    Vongierke, H. E.; Marko, A. R.

    1985-04-01

    This invention involves measurement of the visual contrast sensitivity (modulation transfer) function of a human subject by means of linear or circular spatial frequency pattern on a cathode ray tube whose contrast is automatically decreasing or increasing depending on the subject pressing or releasing a hand-switch button. The threshold of detection of the pattern modulation is found by the subject by adjusting the contrast to values which vary about the subject's threshold thereby determining the threshold and also providing by the magnitude of the contrast fluctuations between reversals some estimate of the variability of the subject's absolute threshold. The invention also involves the slow automatic sweeping of the spatial frequency of the pattern over the spatial frequencies after preset time intervals or after threshold has been defined at each frequency by a selected number of subject-determined threshold crossings; i.e., contrast reversals.

  13. A contrast-sensitive channelized-Hotelling observer to predict human performance in a detection task using lumpy backgrounds and Gaussian signals

    NASA Astrophysics Data System (ADS)

    Park, Subok; Badano, Aldo; Gallas, Brandon D.; Myers, Kyle J.

    2007-03-01

    Previously, a non-prewhitening matched filter (NPWMF) incorporating a model for the contrast sensitivity of the human visual system was introduced for modeling human performance in detection tasks with different viewing angles and white-noise backgrounds by Badano et al. But NPWMF observers do not perform well detection tasks involving complex backgrounds since they do not account for random backgrounds. A channelized-Hotelling observer (CHO) using difference-of-Gaussians (DOG) channels has been shown to track human performance well in detection tasks using lumpy backgrounds. In this work, a CHO with DOG channels, incorporating the model of the human contrast sensitivity, was developed similarly. We call this new observer a contrast-sensitive CHO (CS-CHO). The Barten model was the basis of our human contrast sensitivity model. A scalar was multiplied to the Barten model and varied to control the thresholding effect of the contrast sensitivity on luminance-valued images and hence the performance-prediction ability of the CS-CHO. The performance of the CS-CHO was compared to the average human performance from the psychophysical study by Park et al., where the task was to detect a known Gaussian signal in non-Gaussian distributed lumpy backgrounds. Six different signal-intensity values were used in this study. We chose the free parameter of our model to match the mean human performance in the detection experiment at the strongest signal intensity. Then we compared the model to the human at five different signal-intensity values in order to see if the performance of the CS-CHO matched human performance. Our results indicate that the CS-CHO with the chosen scalar for the contrast sensitivity predicts human performance closely as a function of signal intensity.

  14. Long lasting effects of daily theta burst rTMS sessions in the human amblyopic cortex.

    PubMed

    Clavagnier, Simon; Thompson, Benjamin; Hess, Robert F

    2013-11-01

    It has been reported that a single session of 1 Hz or 10 Hz repetitive transcranial magnetic stimulation (rTMS) of the visual cortex can temporarily improve contrast sensitivity in adults with amblyopia. More recently, continuous theta burst stimulation (cTBS) of the visual cortex has been found to improve contrast sensitivity in observers with normal vision. The aims of this study were to assess whether cTBS of the visual cortex could improve contrast sensitivity in adults with amblyopia and whether repeated sessions of cTBS would lead to more pronounced and/or longer lasting effects. cTBS was delivered to the visual cortex while patients viewed a high contrast stimulus with their non-amblyopic eye. This manipulation was designed to bias the effects of cTBS toward inputs from the amblyopic eye. Contrast sensitivity was measured before and after stimulation. The effects of one cTBS session were measured in five patients and the effects of five consecutive daily sessions were measured in four patients. Three patients were available for follow-up at varying intervals after the final session. cTBS improved amblyopic eye contrast sensitivity to high spatial frequencies (P < 0.05) and there was a cumulative improvement across sessions with asymptotic improvement occurring after 2 daily sessions of stimulation. The contrast sensitivity improvements were stable over a period of up to 78 days. These initial results in a small number of patients indicate the cTBS may allow for enduring visual function improvements in adults with amblyopia. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Visible contrast energy metrics for detection and discrimination

    NASA Astrophysics Data System (ADS)

    Ahumada, Albert J.; Watson, Andrew B.

    2013-03-01

    Contrast energy was proposed by Watson, Barlow, and Robson (Science, 1983) as a useful metric for representing luminance contrast target stimuli because it represents the detectability of the stimulus in photon noise for an ideal observer. We propose here the use of visible contrast energy metrics for detection and discrimination among static luminance patterns. The visibility is approximated with spatial frequency sensitivity weighting and eccentricity sensitivity weighting. The suggested weighting functions revise the Standard Spatial Observer (Watson and Ahumada, J. Vision, 2005) for luminance contrast detection , extend it into the near periphery, and provide compensation for duration. Under the assumption that the detection is limited only by internal noise, both detection and discrimination performance can be predicted by metrics based on the visible energy of the difference images.

  16. Children's Contrast Sensitivity Function in Relation to Organophosphate Insecticide Prenatal Exposure in the Mother-Child PELAGIE Cohort.

    PubMed

    Cartier, Chloé; Warembourg, Charline; Monfort, Christine; Rouget, Florence; Limon, Gwendolina; Durand, Gaël; Cordier, Sylvaine; Saint-Amour, Dave; Chevrier, Cécile

    2018-05-24

    Human exposure to organophosphate pesticides (OP) is widespread. Several studies suggest that OP prenatal exposure alters the development of cognitive and behavioural functions in children, but the effects of OP prenatal exposure on child sensory functions are largely unknown. The aim of the study was to evaluate the association between OP prenatal exposure and visual processing in school-aged children from the mother-child PELAGIE cohort (France). OP biomarkers of exposure were measured in maternal urine samples at the beginning of pregnancy. The Functional Acuity Contrast Test (FACT) was used to assess visual contrast sensitivity in 180 children at 6 years of age. Linear regression models were performed on all children, and separately for boys and girls, taking into account various potential confounders, including maternal education and breastfeeding. No associations were observed in the whole sample, while maternal OP urinary metabolite levels were associated with a decrease of FACT scores in boys. These findings indicate that OP prenatal exposure might impair visual processing later in life in boys only. Copyright © 2018. Published by Elsevier B.V.

  17. Steady-State Contrast Response Functions Provide a Sensitive and Objective Index of Amblyopic Deficits

    PubMed Central

    Baker, Daniel H.; Simard, Mathieu; Saint-Amour, Dave; Hess, Robert F.

    2015-01-01

    Purpose. Visual deficits in amblyopia are neural in origin, yet are difficult to characterize with functional magnetic resonance imagery (fMRI). Our aim was to develop an objective electroencephalography (EEG) paradigm that can be used to provide a clinically useful index of amblyopic deficits. Methods. We used steady-state visual evoked potentials (SSVEPs) to measure full contrast response functions in both amblyopic (n = 10, strabismic or mixed amblyopia, mean age: 44 years) and control (n = 5, mean age: 31 years) observers, both with and without a dichoptic mask. Results. At the highest target contrast, the ratio of amplitudes across the weaker and stronger eyes was highly correlated (r = 0.76) with the acuity ratio between the eyes. We also found that the contrast response function in the amblyopic eye had both a greatly reduced amplitude and a shallower slope, but that surprisingly dichoptic masking was weaker than in controls. The results were compared with the predictions of a computational model of amblyopia and suggest a modification to the model whereby excitatory (but not suppressive) signals are attenuated in the amblyopic eye. Conclusions. We suggest that SSVEPs offer a sensitive and objective measure of the ocular imbalance in amblyopia and could be used to assess the efficacy of amblyopia therapies currently under development. PMID:25634977

  18. Magnetic particle imaging for radiation-free, sensitive and high-contrast vascular imaging and cell tracking.

    PubMed

    Zhou, Xinyi Y; Tay, Zhi Wei; Chandrasekharan, Prashant; Yu, Elaine Y; Hensley, Daniel W; Orendorff, Ryan; Jeffris, Kenneth E; Mai, David; Zheng, Bo; Goodwill, Patrick W; Conolly, Steven M

    2018-05-10

    Magnetic particle imaging (MPI) is an emerging ionizing radiation-free biomedical tracer imaging technique that directly images the intense magnetization of superparamagnetic iron oxide nanoparticles (SPIOs). MPI offers ideal image contrast because MPI shows zero signal from background tissues. Moreover, there is zero attenuation of the signal with depth in tissue, allowing for imaging deep inside the body quantitatively at any location. Recent work has demonstrated the potential of MPI for robust, sensitive vascular imaging and cell tracking with high contrast and dose-limited sensitivity comparable to nuclear medicine. To foster future applications in MPI, this new biomedical imaging field is welcoming researchers with expertise in imaging physics, magnetic nanoparticle synthesis and functionalization, nanoscale physics, and small animal imaging applications. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Spatial resolution, contrast sensitivity, and sensitivity to defocus of chicken retinal ganglion cells in vitro.

    PubMed

    Diedrich, Erich; Schaeffel, Frank

    2009-11-01

    The chicken has been extensively studied as an animal model for myopia because its eye growth is tightly controlled by visual experience. It has been found that the retina controls the axial eye growth rates depending on the amount and the sign of defocus imposed in the projected image. Glucagonergic amacrine cells were discovered that appear to encode for the sign of imposed defocus. It is not clear whether the downstream neurons, the retinal ganglion cells, still have access to this information-and whether it ultimately reaches the brain. We have analyzed the spike rates of chicken retinal ganglion cells in vitro using a microelectrode array. For this purpose, we initially defined spatial resolution and contrast sensitivity in vitro. Two classes of chicken retinal ganglions were found, depending on the linearity of their responses with increasing contrast. Responses generally declined with increasing defocus of the visual stimulus. These responses were well predicted by the modulation transfer function for a diffraction-limited defocused optical system, the first Bessel function. Thus, the studied retinal ganglion cells did not distinguish between a loss of contrast at a given spatial frequency due to reduced contrast of the stimulus pattern or because the pattern was presented out of focus. Furthermore, there was no indication that the retinal ganglion cells responded differently to defocus of either sign, at least for the cells that were recorded in this study.

  20. High-resolution contrast-enhanced optical coherence tomography in mice retinae

    NASA Astrophysics Data System (ADS)

    Sen, Debasish; SoRelle, Elliott D.; Liba, Orly; Dalal, Roopa; Paulus, Yannis M.; Kim, Tae-Wan; Moshfeghi, Darius M.; de la Zerda, Adam

    2016-06-01

    Optical coherence tomography (OCT) is a noninvasive interferometric imaging modality providing anatomical information at depths of millimeters and a resolution of micrometers. Conventional OCT images limit our knowledge to anatomical structures alone, without any contrast enhancement. Therefore, here we have, for the first time, optimized an OCT-based contrast-enhanced imaging system for imaging single cells and blood vessels in vivo inside the living mouse retina at subnanomolar sensitivity. We used bioconjugated gold nanorods (GNRs) as exogenous OCT contrast agents. Specifically, we used anti-mouse CD45 coated GNRs to label mouse leukocytes and mPEG-coated GNRs to determine sensitivity of GNR detection in vivo inside mice retinae. We corroborated OCT observations with hyperspectral dark-field microscopy of formalin-fixed histological sections. Our results show that mouse leukocytes that otherwise do not produce OCT contrast can be labeled with GNRs leading to significant OCT intensity equivalent to a 0.5 nM GNR solution. Furthermore, GNRs injected intravenously can be detected inside retinal blood vessels at a sensitivity of ˜0.5 nM, and GNR-labeled cells injected intravenously can be detected inside retinal capillaries by enhanced OCT contrast. We envision the unprecedented resolution and sensitivity of functionalized GNRs coupled with OCT to be adopted for longitudinal studies of retinal disorders.

  1. Blur adaptation: contrast sensitivity changes and stimulus extent.

    PubMed

    Venkataraman, Abinaya Priya; Winter, Simon; Unsbo, Peter; Lundström, Linda

    2015-05-01

    A prolonged exposure to foveal defocus is well known to affect the visual functions in the fovea. However, the effects of peripheral blur adaptation on foveal vision, or vice versa, are still unclear. In this study, we therefore examined the changes in contrast sensitivity function from baseline, following blur adaptation to small as well as laterally extended stimuli in four subjects. The small field stimulus (7.5° visual field) was a 30min video of forest scenery projected on a screen and the large field stimulus consisted of 7-tiles of the 7.5° stimulus stacked horizontally. Both stimuli were used for adaptation with optical blur (+2.00D trial lens) as well as for clear control conditions. After small field blur adaptation foveal contrast sensitivity improved in the mid spatial frequency region. However, these changes neither spread to the periphery nor occurred for the large field blur adaptation. To conclude, visual performance after adaptation is dependent on the lateral extent of the adaptation stimulus. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. Culture-Sensitive Functional Analytic Psychotherapy

    ERIC Educational Resources Information Center

    Vandenberghe, L.

    2008-01-01

    Functional analytic psychotherapy (FAP) is defined as behavior-analytically conceptualized talk therapy. In contrast to the technique-oriented educational format of cognitive behavior therapy and the use of structural mediational models, FAP depends on the functional analysis of the moment-to-moment stream of interactions between client and…

  3. VEP contrast sensitivity responses reveal reduced functional segregation of mid and high filters of visual channels in autism.

    PubMed

    Jemel, Boutheina; Mimeault, Daniel; Saint-Amour, Dave; Hosein, Anthony; Mottron, Laurent

    2010-06-01

    Despite the vast amount of behavioral data showing a pronounced tendency in individuals with autism spectrum disorder (ASD) to process fine visual details, much less is known about the neurophysiological characteristics of spatial vision in ASD. Here, we address this issue by assessing the contrast sensitivity response properties of the early visual-evoked potentials (VEPs) to sine-wave gratings of low, medium and high spatial frequencies in adults with ASD and in an age- and IQ-matched control group. Our results show that while VEP contrast responses to low and high spatial frequency gratings did not differ between ASD and controls, early VEPs to mid spatial frequency gratings exhibited similar response characteristics as those to high spatial frequency gratings in ASD. Our findings show evidence for an altered functional segregation of early visual channels, especially those responsible for processing mid- and high-frequency spatial scales.

  4. Visual detection following retinal damage: predictions of an inhomogeneous retino-cortical model

    NASA Astrophysics Data System (ADS)

    Arnow, Thomas L.; Geisler, Wilson S.

    1996-04-01

    A model of human visual detection performance has been developed, based on available anatomical and physiological data for the primate visual system. The inhomogeneous retino- cortical (IRC) model computes detection thresholds by comparing simulated neural responses to target patterns with responses to a uniform background of the same luminance. The model incorporates human ganglion cell sampling distributions; macaque monkey ganglion cell receptive field properties; macaque cortical cell contrast nonlinearities; and a optical decision rule based on ideal observer theory. Spatial receptive field properties of cortical neurons were not included. Two parameters were allowed to vary while minimizing the squared error between predicted and observed thresholds. One parameter was decision efficiency, the other was the relative strength of the ganglion-cell center and surround. The latter was only allowed to vary within a small range consistent with known physiology. Contrast sensitivity was measured for sinewave gratings as a function of spatial frequency, target size and eccentricity. Contrast sensitivity was also measured for an airplane target as a function of target size, with and without artificial scotomas. The results of these experiments, as well as contrast sensitivity data from the literature were compared to predictions of the IRC model. Predictions were reasonably good for grating and airplane targets.

  5. Detecting activity-evoked pH changes in human brain

    PubMed Central

    Magnotta, Vincent A.; Heo, Hye-Young; Dlouhy, Brian J.; Dahdaleh, Nader S.; Follmer, Robin L.; Thedens, Daniel R.; Welsh, Michael J.; Wemmie, John A.

    2012-01-01

    Localized pH changes have been suggested to occur in the brain during normal function. However, the existence of such pH changes has also been questioned. Lack of methods for noninvasively measuring pH with high spatial and temporal resolution has limited insight into this issue. Here we report that a magnetic resonance imaging (MRI) strategy, T1 relaxation in the rotating frame (T1ρ), is sufficiently sensitive to detect widespread pH changes in the mouse and human brain evoked by systemically manipulating carbon dioxide or bicarbonate. Moreover, T1ρ detected a localized acidosis in the human visual cortex induced by a flashing checkerboard. Lactate measurements and pH-sensitive 31P spectroscopy at the same site also identified a localized acidosis. Consistent with the established role for pH in blood flow recruitment, T1ρ correlated with blood oxygenation level-dependent contrast commonly used in functional MRI. However, T1ρ was not directly sensitive to blood oxygen content. These observations indicate that localized pH fluctuations occur in the human brain during normal function. Furthermore, they suggest a unique functional imaging strategy based on pH that is independent of traditional functional MRI contrast mechanisms. PMID:22566645

  6. Color, contrast sensitivity, and the cone mosaic.

    PubMed Central

    Williams, D; Sekiguchi, N; Brainard, D

    1993-01-01

    This paper evaluates the role of various stages in the human visual system in the detection of spatial patterns. Contrast sensitivity measurements were made for interference fringe stimuli in three directions in color space with a psychophysical technique that avoided blurring by the eye's optics including chromatic aberration. These measurements were compared with the performance of an ideal observer that incorporated optical factors, such as photon catch in the cone mosaic, that influence the detection of interference fringes. The comparison of human and ideal observer performance showed that neural factors influence the shape as well as the height of the foveal contrast sensitivity function for all color directions, including those that involve luminance modulation. Furthermore, when optical factors are taken into account, the neural visual system has the same contrast sensitivity for isoluminant stimuli seen by the middle-wavelength-sensitive (M) and long-wavelength-sensitive (L) cones and isoluminant stimuli seen by the short-wavelength-sensitive (S) cones. Though the cone submosaics that feed these chromatic mechanisms have very different spatial properties, the later neural stages apparently have similar spatial properties. Finally, we review the evidence that cone sampling can produce aliasing distortion for gratings with spatial frequencies exceeding the resolution limit. Aliasing can be observed with gratings modulated in any of the three directions in color space we used. We discuss mechanisms that prevent aliasing in most ordinary viewing conditions. Images Fig. 1 Fig. 8 PMID:8234313

  7. Optimization of neural retinal visual motor strategies in recovery of visual acuity following acute laser-induced macula injury

    NASA Astrophysics Data System (ADS)

    Zwick, Harry; Ness, James W.; Loveday, J.; Molchany, Jerome W.; Stuck, Bruce E.

    1997-05-01

    Laser induced damage to the retina may produce immediate and serious loss in visual acuity as well as subsequent recovery of visual acuity over a 1 to 6 month post exposure period. While acuity may recover, full utilization of the foveal region may not return. In one patient, a superior/temporal preferred retinal location (PRL) was apparent, while a second patient demonstrated significant foveal involvement and contrast sensitivity more reflective of foveal than parafoveal involvement. These conditions of injury wee simulated by using an artificial scotoma technique which optically stabilized a 5 degree opacity in the center of the visual field. The transmission of spatially degraded target information in the scotoma was 0 percent, 5 percent and 95 percent. Contrast sensitivity for the 0 percent and 5 percent transmission scotoma showed broad spatial frequency suppression as opposed to a bipartite contrast sensitivity function with a narrow sensitivity loss at 3 cycles/degree for the 95 percent transmission scotoma. A PRL shift to superior temporal retina with a concomitant change in accommodation was noted as target resolution became more demanding. These findings suggest that restoration of visual acuity in human laser accidents may depend upon the functionality of complex retinal and cortical adaptive mechanisms.

  8. [Visual function evaluation in human immunodeficiency virus carriers].

    PubMed

    Solís-Castillo, A; Ramírez-Ponce, L A; Valdez-González, T; Seijo, E; Voorduin-Ramos, S; López-Star, E M

    2011-04-01

    To determine whether there are changes in the peripapillary nerve fibre layer, in colour vision, contrast sensitivity, dark adaptation and electroretinography changes in these patients who do not have infectious retinitis. We studied 52 patients without ocular pathology; the mean age was 35.88 years old. We observed less thickness in all quadrants, except the nasal. The colour vision was altered in 27.77% of the patients. The contrast sensitivity test showed high frequency alterations. There was no statistically significant difference in the electroretinography test or in dark adaptation. There are changes in the peripapillary nerve fibre layer thickness; also we found changes in colour vision, contrast sensitivity and a decreasing trend of the B wave in the electroreninogram. Copyright © 2010 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  9. Capturing age-related changes in functional contrast sensitivity with decreasing light levels in monocular and binocular vision.

    PubMed

    Gillespie-Gallery, Hanna; Konstantakopoulou, Evgenia; Harlow, Jonathan A; Barbur, John L

    2013-09-09

    It is challenging to separate the effects of normal aging of the retina and visual pathways independently from optical factors, decreased retinal illuminance, and early stage disease. This study determined limits to describe the effect of light level on normal, age-related changes in monocular and binocular functional contrast sensitivity. We recruited 95 participants aged 20 to 85 years. Contrast thresholds for correct orientation discrimination of the gap in a Landolt C optotype were measured using a 4-alternative, forced-choice (4AFC) procedure at screen luminances from 34 to 0.12 cd/m(2) at the fovea and parafovea (0° and ±4°). Pupil size was measured continuously. The Health of the Retina index (HRindex) was computed to capture the loss of contrast sensitivity with decreasing light level. Participants were excluded if they exhibited performance outside the normal limits of interocular differences or HRindex values, or signs of ocular disease. Parafoveal contrast thresholds showed a steeper decline and higher correlation with age at the parafovea than the fovea. Of participants with clinical signs of ocular disease, 83% had HRindex values outside the normal limits. Binocular summation of contrast signals declined with age, independent of interocular differences. The HRindex worsens more rapidly with age at the parafovea, consistent with histologic findings of rod loss and its link to age-related degenerative disease of the retina. The HRindex and interocular differences could be used to screen for and separate the earliest stages of subclinical disease from changes caused by normal aging.

  10. The role of pulvinar in the transmission of information in the visual hierarchy.

    PubMed

    Cortes, Nelson; van Vreeswijk, Carl

    2012-01-01

    VISUAL RECEPTIVE FIELD (RF) ATTRIBUTES IN VISUAL CORTEX OF PRIMATES HAVE BEEN EXPLAINED MAINLY FROM CORTICAL CONNECTIONS: visual RFs progress from simple to complex through cortico-cortical pathways from lower to higher levels in the visual hierarchy. This feedforward flow of information is paired with top-down processes through the feedback pathway. Although the hierarchical organization explains the spatial properties of RFs, is unclear how a non-linear transmission of activity through the visual hierarchy can yield smooth contrast response functions in all level of the hierarchy. Depending on the gain, non-linear transfer functions create either a bimodal response to contrast, or no contrast dependence of the response in the highest level of the hierarchy. One possible mechanism to regulate this transmission of visual contrast information from low to high level involves an external component that shortcuts the flow of information through the hierarchy. A candidate for this shortcut is the Pulvinar nucleus of the thalamus. To investigate representation of stimulus contrast a hierarchical model network of ten cortical areas is examined. In each level of the network, the activity from the previous layer is integrated and then non-linearly transmitted to the next level. The arrangement of interactions creates a gradient from simple to complex RFs of increasing size as one moves from lower to higher cortical levels. The visual input is modeled as a Gaussian random input, whose width codes for the contrast. This input is applied to the first area. The output activity ratio among different contrast values is analyzed for the last level to observe sensitivity to a contrast and contrast invariant tuning. For a purely cortical system, the output of the last area can be approximately contrast invariant, but the sensitivity to contrast is poor. To account for an alternative visual processing pathway, non-reciprocal connections from and to a parallel pulvinar like structure of nine areas is coupled to the system. Compared to the pure feedforward model, cortico-pulvino-cortical output presents much more sensitivity to contrast and has a similar level of contrast invariance of the tuning.

  11. The Role of Pulvinar in the Transmission of Information in the Visual Hierarchy

    PubMed Central

    Cortes, Nelson; van Vreeswijk, Carl

    2012-01-01

    Visual receptive field (RF) attributes in visual cortex of primates have been explained mainly from cortical connections: visual RFs progress from simple to complex through cortico-cortical pathways from lower to higher levels in the visual hierarchy. This feedforward flow of information is paired with top-down processes through the feedback pathway. Although the hierarchical organization explains the spatial properties of RFs, is unclear how a non-linear transmission of activity through the visual hierarchy can yield smooth contrast response functions in all level of the hierarchy. Depending on the gain, non-linear transfer functions create either a bimodal response to contrast, or no contrast dependence of the response in the highest level of the hierarchy. One possible mechanism to regulate this transmission of visual contrast information from low to high level involves an external component that shortcuts the flow of information through the hierarchy. A candidate for this shortcut is the Pulvinar nucleus of the thalamus. To investigate representation of stimulus contrast a hierarchical model network of ten cortical areas is examined. In each level of the network, the activity from the previous layer is integrated and then non-linearly transmitted to the next level. The arrangement of interactions creates a gradient from simple to complex RFs of increasing size as one moves from lower to higher cortical levels. The visual input is modeled as a Gaussian random input, whose width codes for the contrast. This input is applied to the first area. The output activity ratio among different contrast values is analyzed for the last level to observe sensitivity to a contrast and contrast invariant tuning. For a purely cortical system, the output of the last area can be approximately contrast invariant, but the sensitivity to contrast is poor. To account for an alternative visual processing pathway, non-reciprocal connections from and to a parallel pulvinar like structure of nine areas is coupled to the system. Compared to the pure feedforward model, cortico-pulvino-cortical output presents much more sensitivity to contrast and has a similar level of contrast invariance of the tuning. PMID:22654750

  12. Functional Nanoparticles for Magnetic Resonance Imaging

    PubMed Central

    Mao, Xinpei; Xu, Jiadi; Cui, Honggang

    2016-01-01

    Nanoparticle-based magnetic resonance imaging (MRI) contrast agents have received much attention over the past decade. By virtue of a high payload of magnetic moieties, enhanced accumulation at disease sites, and a large surface area for additional modification with targeting ligands, nanoparticle-based contrast agents offer promising new platforms to further enhance the high resolution and sensitivity of MRI for various biomedical applications. T2* superparamagnetic iron oxide nanoparticles (SPIONs) first demonstrated superior improvement on MRI sensitivity. The prevailing SPION attracted growing interest in the development of refined nanoscale versions of MRI contrast agents. Afterwards, T1-based contrast agents were developed, and became the most studied subject in MRI due to the positive contrast they provide that avoids the susceptibility associated with MRI signal reduction. Recently, chemical exchange saturation transfer (CEST) contrast agents have emerged and rapidly gained popularity. The unique aspect of CEST contrast agents is that their contrast can be selectively turned “on” and “off” by radiofrequency (RF) saturation. Their performance can be further enhanced by incorporating a large number of exchangeable protons into well-defined nanostructure. Besides activatable CEST contrast agents, there is growing interest in developing nanoparticle-based activatable MRI contrast agents responsive to stimuli (pH, enzyme, etc.), which improves sensitivity and specificity. In this review, we summarize the recent development of various types of nanoparticle-based MRI contrast agents, and have focused our discussions on the key advantages of introducing nanoparticles in MRI. PMID:27040463

  13. Positron emission mammography (PEM): Effect of activity concentration, object size, and object contrast on phantom lesion detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacDonald, Lawrence R.; Wang, Carolyn L.; Eissa, Marna

    2012-10-15

    Purpose: To characterize the relationship between lesion detection sensitivity and injected activity as a function of lesion size and contrast on the PEM (positron emission mammography) Flex Solo II scanner using phantom experiments. Methods: Phantom lesions (spheres 4, 8, 12, 16, and 20 mm diameter) were randomly located in uniform background. Sphere activity concentrations were 3 to 21 times the background activity concentration (BGc). BGc was a surrogate for injected activity; BGc ranged from 0.44-4.1 kBq/mL, corresponding to 46-400 MBq injections. Seven radiologists read 108 images containing zero, one, or two spheres. Readers used a 5-point confidence scale to scoremore » the presence of spheres. Results: Sensitivity was 100% for lesions {>=}12 mm under all conditions except for one 12 mm sphere with the lowest contrast and lowest BGc (60% sensitivity). Sensitivity was 100% for 8 mm spheres when either contrast or BGc was high, and 100% for 4 mm spheres only when both contrast and BGc were highest. Sphere contrast recovery coefficients (CRC) were 49%, 34%, 26%, 14%, and 2.8% for the largest to smallest spheres. Cumulative specificity was 98%. Conclusions: Phantom lesion detection sensitivity depends more on sphere size and contrast than on BGc. Detection sensitivity remained {>=}90% for injected activities as low as 100 MBq, for lesions {>=}8 mm. Low CRC in 4 mm objects results in moderate detection sensitivity even for 400 MBq injected activity, making it impractical to optimize injected activity for such lesions. Low CRC indicates that when lesions <8 mm are observed on PEM images they are highly tracer avid with greater potential of clinical significance. High specificity (98%) suggests that image statistical noise does not lead to false positive findings. These results apply to the 85 mm thick object used to obtain them; lesion detectability should be better (worse) for thinner (thicker) objects based on the reduced (increased) influence of photon attenuation.« less

  14. Punishment sensitivity modulates the processing of negative feedback but not error-induced learning.

    PubMed

    Unger, Kerstin; Heintz, Sonja; Kray, Jutta

    2012-01-01

    Accumulating evidence suggests that individual differences in punishment and reward sensitivity are associated with functional alterations in neural systems underlying error and feedback processing. In particular, individuals highly sensitive to punishment have been found to be characterized by larger mediofrontal error signals as reflected in the error negativity/error-related negativity (Ne/ERN) and the feedback-related negativity (FRN). By contrast, reward sensitivity has been shown to relate to the error positivity (Pe). Given that Ne/ERN, FRN, and Pe have been functionally linked to flexible behavioral adaptation, the aim of the present research was to examine how these electrophysiological reflections of error and feedback processing vary as a function of punishment and reward sensitivity during reinforcement learning. We applied a probabilistic learning task that involved three different conditions of feedback validity (100%, 80%, and 50%). In contrast to prior studies using response competition tasks, we did not find reliable correlations between punishment sensitivity and the Ne/ERN. Instead, higher punishment sensitivity predicted larger FRN amplitudes, irrespective of feedback validity. Moreover, higher reward sensitivity was associated with a larger Pe. However, only reward sensitivity was related to better overall learning performance and higher post-error accuracy, whereas highly punishment sensitive participants showed impaired learning performance, suggesting that larger negative feedback-related error signals were not beneficial for learning or even reflected maladaptive information processing in these individuals. Thus, although our findings indicate that individual differences in reward and punishment sensitivity are related to electrophysiological correlates of error and feedback processing, we found less evidence for influences of these personality characteristics on the relation between performance monitoring and feedback-based learning.

  15. Effect of signal intensity and camera quantization on laser speckle contrast analysis

    PubMed Central

    Song, Lipei; Elson, Daniel S.

    2012-01-01

    Laser speckle contrast analysis (LASCA) is limited to being a qualitative method for the measurement of blood flow and tissue perfusion as it is sensitive to the measurement configuration. The signal intensity is one of the parameters that can affect the contrast values due to the quantization of the signals by the camera and analog-to-digital converter (ADC). In this paper we deduce the theoretical relationship between signal intensity and contrast values based on the probability density function (PDF) of the speckle pattern and simplify it to a rational function. A simple method to correct this contrast error is suggested. The experimental results demonstrate that this relationship can effectively compensate the bias in contrast values induced by the quantized signal intensity and correct for bias induced by signal intensity variations across the field of view. PMID:23304650

  16. [Sensitivity and specificity of flicker perimetry with Pulsar. Comparison with achromatic (white-on-white) perimetry in glaucoma patients].

    PubMed

    Göbel, K; Erb, C

    2013-02-01

    The early detection of functional glaucoma damage plays an increasingly more central role in the diagnosis and treatment of glaucoma disease. Using selective perimetry detection of early glaucomatous defects is more likely and one of these methods is flicker perimetry with Pulsar. Flicker perimetry is used to analyze the temporal visual function in combination with spatial resolution and contrast sensitivity as opposed to standard automated perimetry which measures the differential light sensitivity with a non-specific stimulus. This study showed a higher sensitivity and specificity of Pulsar perimetry in comparison to achromatic perimetry in glaucoma patients.

  17. Visual acuity and contrast sensitivity are two important factors affecting vision-related quality of life in advanced age-related macular degeneration

    PubMed Central

    Selivanova, Alexandra; Shin, Hyun Joon; Miller, Joan W.; Jackson, Mary Lou

    2018-01-01

    Purpose Vision loss from age-related macular degeneration (AMD) has a profound effect on vision-related quality of life (VRQoL). The pupose of this study is to identify clinical factors associated with VRQoL using the Rasch- calibrated NEI VFQ-25 scales in bilateral advanced AMD patients. Methods We retrospectively reviewed 47 patients (mean age 83.2 years) with bilateral advanced AMD. Clinical assessment included age, gender, type of AMD, high contrast visual acuity (VA), history of medical conditions, contrast sensitivity (CS), central visual field loss, report of Charles Bonnet Syndrome, current treatment for AMD and Rasch-calibrated NEI VFQ-25 visual function and socioemotional function scales. The NEI VFQ visual function scale includes items of general vision, peripheral vision, distance vision and near vision-related activity while the socioemotional function scale includes items of vision related-social functioning, role difficulties, dependency, and mental health. Multiple regression analysis (structural regression model) was performed using fixed item parameters obtained from the one-parameter item response theory model. Results Multivariate analysis showed that high contrast VA and CS were two factors influencing VRQoL visual function scale (β = -0.25, 95% CI-0.37 to -0.12, p<0.001 and β = 0.35, 95% CI 0.25 to 0.46, p<0.001) and socioemontional functioning scale (β = -0.2, 95% CI -0.37 to -0.03, p = 0.023, and β = 0.3, 95% CI 0.18 to 0.43, p = 0.001). Central visual field loss was not assoicated with either VRQoL visual or socioemontional functioning scale (β = -0.08, 95% CI-0.28 to 0.12,p = 0.44 and β = -0.09, 95% CI -0.03 to 0.16, p = 0.50, respectively). Conclusion In patients with vision impairment secondary to bilateral advanced AMD, high contrast VA and CS are two important factors affecting VRQoL. PMID:29746512

  18. Visual acuity and contrast sensitivity are two important factors affecting vision-related quality of life in advanced age-related macular degeneration.

    PubMed

    Roh, Miin; Selivanova, Alexandra; Shin, Hyun Joon; Miller, Joan W; Jackson, Mary Lou

    2018-01-01

    Vision loss from age-related macular degeneration (AMD) has a profound effect on vision-related quality of life (VRQoL). The pupose of this study is to identify clinical factors associated with VRQoL using the Rasch- calibrated NEI VFQ-25 scales in bilateral advanced AMD patients. We retrospectively reviewed 47 patients (mean age 83.2 years) with bilateral advanced AMD. Clinical assessment included age, gender, type of AMD, high contrast visual acuity (VA), history of medical conditions, contrast sensitivity (CS), central visual field loss, report of Charles Bonnet Syndrome, current treatment for AMD and Rasch-calibrated NEI VFQ-25 visual function and socioemotional function scales. The NEI VFQ visual function scale includes items of general vision, peripheral vision, distance vision and near vision-related activity while the socioemotional function scale includes items of vision related-social functioning, role difficulties, dependency, and mental health. Multiple regression analysis (structural regression model) was performed using fixed item parameters obtained from the one-parameter item response theory model. Multivariate analysis showed that high contrast VA and CS were two factors influencing VRQoL visual function scale (β = -0.25, 95% CI-0.37 to -0.12, p<0.001 and β = 0.35, 95% CI 0.25 to 0.46, p<0.001) and socioemontional functioning scale (β = -0.2, 95% CI -0.37 to -0.03, p = 0.023, and β = 0.3, 95% CI 0.18 to 0.43, p = 0.001). Central visual field loss was not assoicated with either VRQoL visual or socioemontional functioning scale (β = -0.08, 95% CI-0.28 to 0.12,p = 0.44 and β = -0.09, 95% CI -0.03 to 0.16, p = 0.50, respectively). In patients with vision impairment secondary to bilateral advanced AMD, high contrast VA and CS are two important factors affecting VRQoL.

  19. Evaluation of the precision of contrast sensitivity function assessment on a tablet device

    PubMed Central

    Dorr, Michael; Lesmes, Luis A.; Elze, Tobias; Wang, Hui; Lu, Zhong-Lin; Bex, Peter J.

    2017-01-01

    The contrast sensitivity function (CSF) relates the visibility of a spatial pattern to both its size and contrast, and is therefore a more comprehensive assessment of visual function than acuity, which only determines the smallest resolvable pattern size. Because of the additional dimension of contrast, estimating the CSF can be more time-consuming. Here, we compare two methods for rapid assessment of the CSF that were implemented on a tablet device. For a single-trial assessment, we asked 63 myopes and 38 emmetropes to tap the peak of a “sweep grating” on the tablet’s touch screen. For a more precise assessment, subjects performed 50 trials of the quick CSF method in a 10-AFC letter recognition task. Tests were performed with and without optical correction, and in monocular and binocular conditions; one condition was measured twice to assess repeatability. Results show that both methods are highly correlated; using both common and novel measures for test-retest repeatability, however, the quick CSF delivers more precision with testing times of under three minutes. Further analyses show how a population prior can improve convergence rate of the quick CSF, and how the multi-dimensional output of the quick CSF can provide greater precision than scalar outcome measures. PMID:28429773

  20. Detection of briefly flashed sine-gratings in dark-adapted vision.

    PubMed

    Hofmann, M I; Barnes, C S; Hallett, P E

    1990-01-01

    Scotopic contrast sensitivity was measured near 20 deg retinal eccentricity for briefly flashed (10 or 20 msec) sine-wave gratings presented in darkness to dark-adapted subjects. For very low spatial frequencies (0.2-0.5 c/deg), curves of contrast sensitivity vs luminous energy show evidence of a low rod plateau and a high scotopic region, with an intervening transition at around -2 to -2.5 log scot td sec. Similar measurements made using long flashed or flickering gratings do not show a plateau. The results suggest that vision in the low rod region is impaired for brief flashes. For the briefly flashed stimuli, curves of contrast sensitivity versus spatial frequency in the low region were best fit by simple Gaussian functions with a variable centre size (sigma c = 0.5----0.25 deg), size decreasing with increasing flash energy. Difference-of-Gaussian functions with constant centre size (sigma c = 0.25 deg) provided the best fit in the high region. Overt input from the cones and grating area artefacts are excluded by appropriate tests. Calculation of photon flux into the receptive field centres suggests that signal compression in P alpha ganglion cells contributes to the low rod plateau.

  1. Psychophysical Evaluation of Achromatic and Chromatic Vision of Workers Chronically Exposed to Organic Solvents

    PubMed Central

    Lacerda, Eliza Maria da Costa Brito; Lima, Monica Gomes; Rodrigues, Anderson Raiol; Teixeira, Cláudio Eduardo Correa; de Lima, Lauro José Barata; Ventura, Dora Fix; Silveira, Luiz Carlos de Lima

    2012-01-01

    The purpose of this paper was to evaluate achromatic and chromatic vision of workers chronically exposed to organic solvents through psychophysical methods. Thirty-one gas station workers (31.5 ± 8.4 years old) were evaluated. Psychophysical tests were achromatic tests (Snellen chart, spatial and temporal contrast sensitivity, and visual perimetry) and chromatic tests (Ishihara's test, color discrimination ellipses, and Farnsworth-Munsell 100 hue test—FM100). Spatial contrast sensitivities of exposed workers were lower than the control at spatial frequencies of 20 and 30 cpd whilst the temporal contrast sensitivity was preserved. Visual field losses were found in 10–30 degrees of eccentricity in the solvent exposed workers. The exposed workers group had higher error values of FM100 and wider color discrimination ellipses area compared to the controls. Workers occupationally exposed to organic solvents had abnormal visual functions, mainly color vision losses and visual field constriction. PMID:22220188

  2. Early-Stage Visual Processing and Cortical Amplification Deficits in Schizophrenia

    PubMed Central

    Butler, Pamela D.; Zemon, Vance; Schechter, Isaac; Saperstein, Alice M.; Hoptman, Matthew J.; Lim, Kelvin O.; Revheim, Nadine; Silipo, Gail; Javitt, Daniel C.

    2005-01-01

    Background Patients with schizophrenia show deficits in early-stage visual processing, potentially reflecting dysfunction of the magnocellular visual pathway. The magnocellular system operates normally in a nonlinear amplification mode mediated by glutamatergic (N-methyl-d-aspartate) receptors. Investigating magnocellular dysfunction in schizophrenia therefore permits evaluation of underlying etiologic hypotheses. Objectives To evaluate magnocellular dysfunction in schizophrenia, relative to known neurochemical and neuroanatomical substrates, and to examine relationships between electrophysiological and behavioral measures of visual pathway dysfunction and relationships with higher cognitive deficits. Design, Setting, and Participants Between-group study at an inpatient state psychiatric hospital and out-patient county psychiatric facilities. Thirty-three patients met DSM-IV criteria for schizophrenia or schizoaffective disorder, and 21 nonpsychiatric volunteers of similar ages composed the control group. Main Outcome Measures (1) Magnocellular and parvocellular evoked potentials, analyzed using nonlinear (Michaelis-Menten) and linear contrast gain approaches; (2) behavioral contrast sensitivity measures; (3) white matter integrity; (4) visual and nonvisual neuropsychological measures, and (5) clinical symptom and community functioning measures. Results Patients generated evoked potentials that were significantly reduced in response to magnocellular-biased, but not parvocellular-biased, stimuli (P=.001). Michaelis-Menten analyses demonstrated reduced contrast gain of the magnocellular system (P=.001). Patients showed decreased contrast sensitivity to magnocellular-biased stimuli (P<.001). Evoked potential deficits were significantly related to decreased white matter integrity in the optic radiations (P<.03). Evoked potential deficits predicted impaired contrast sensitivity (P=.002), which was in turn related to deficits in complex visual processing (P≤.04). Both evoked potential (P≤.04) and contrast sensitivity (P=.01) measures significantly predicted community functioning. Conclusions These findings confirm the existence of early-stage visual processing dysfunction in schizophrenia and provide the first evidence that such deficits are due to decreased nonlinear signal amplification, consistent with glutamatergic theories. Neuroimaging studies support the hypothesis of dysfunction within low-level visual pathways involving thalamocortical radiations. Deficits in early-stage visual processing significantly predict higher cognitive deficits. PMID:15867102

  3. Visual and cognitive predictors of driving safety in Parkinson's disease patients

    PubMed Central

    Amick, M.M.; Grace, J.; Ott, B.R.

    2012-01-01

    This study assessed the clinical utility of contrast sensitivity (CS) relative to attention, executive function, and visuospatial abilities for predicting driving safety in participants with Parkinson's disease (PD). Twenty-five, non-demented PD patients completed measures of contrast sensitivity, visuospatial skills, executive functions, and attention. All PD participants also underwent a formal on-road driving evaluation. Of the 25 participants, 11 received a marginal or unsafe rating on the road test. Poorer driving performance was associated with worse performance on measures of CS, visuospatial constructions, set shifting, and attention. While impaired driving was associated with a range of cognitive and visual abilities, only a composite measure of executive functioning and visuospatial abilities, and not CS or attentional skills, predicted driving performance. These findings suggest that neuropsychological tests, which are multifactorial in nature and require visual perception and visual spatial judgments are the most useful screening measures for hazardous driving in PD patients. PMID:17851032

  4. Visual and cognitive predictors of driving safety in Parkinson's disease patients.

    PubMed

    Amick, M M; Grace, J; Ott, B R

    2007-11-01

    This study assessed the clinical utility of contrast sensitivity (CS) relative to attention, executive function, and visuospatial abilities for predicting driving safety in participants with Parkinson's disease (PD). Twenty-five, non-demented PD patients completed measures of contrast sensitivity, visuospatial skills, executive functions, and attention. All PD participants also underwent a formal on-road driving evaluation. Of the 25 participants, 11 received a marginal or unsafe rating on the road test. Poorer driving performance was associated with worse performance on measures of CS, visuospatial constructions, set shifting, and attention. While impaired driving was associated with a range of cognitive and visual abilities, only a composite measure of executive functioning and visuospatial abilities, and not CS or attentional skills, predicted driving performance. These findings suggest that neuropsychological tests, which are multifactorial in nature and require visual perception and visual spatial judgments are the most useful screening measures for hazardous driving in PD patients.

  5. Music, pandas, and muggers: on the affective psychology of value.

    PubMed

    Hsee, Christopher K; Rottenstreich, Yuval

    2004-03-01

    This research investigated the relationship between the magnitude or scope of a stimulus and its subjective value by contrasting 2 psychological processes that may be used to construct preferences: valuation by feeling and valuation by calculation. The results show that when people rely on feeling, they are sensitive to the presence or absence of a stimulus (i.e., the difference between 0 and some scope) but are largely insensitive to further variations of scope. In contrast, when people rely on calculation, they reveal relatively more constant sensitivity to scope. Thus, value is nearly a step function of scope when feeling predominates and is closer to a linear function when calculation predominates. These findings may allow for a novel interpretation of why most real-world value functions are concave and how the processes responsible for nonlinearity of value may also contribute to nonlinear probability weighting. ((c) 2004 APA, all rights reserved)

  6. Fathers’ Sensitive Parenting and the Development of Early Executive Functioning

    PubMed Central

    Towe-Goodman, Nissa R.; Willoughby, Michael; Blair, Clancy; Gustafsson, Hanna C.; Mills-Koonce, W. Roger; Cox, Martha J.

    2014-01-01

    Using data from a diverse sample of 620 families residing in rural, predominately low-income communities, this study examined longitudinal links between fathers’ sensitive parenting in infancy and toddlerhood and children’s early executive functioning, as well as the contribution of maternal sensitive parenting. After accounting for the quality of concurrent and prior parental care, children’s early cognitive ability, and other child and family factors, fathers’ and mothers’ sensitive and supportive parenting during play at 24-months predicted children’s executive functioning at 3-years of age. In contrast, paternal parenting quality during play at 7-months did not make an independent contribution above that of maternal care, but the links between maternal sensitive and supportive parenting and executive functioning seemed to operate in similar ways during infancy and toddlerhood. These findings add to prior work on early experience and children’s executive functioning, suggesting that both fathers and mothers play a distinct and complementary role in the development of these self-regulatory skills. PMID:25347539

  7. Fathers' sensitive parenting and the development of early executive functioning.

    PubMed

    Towe-Goodman, Nissa R; Willoughby, Michael; Blair, Clancy; Gustafsson, Hanna C; Mills-Koonce, W Roger; Cox, Martha J

    2014-12-01

    Using data from a diverse sample of 620 families residing in rural, predominately low-income communities, this study examined longitudinal links between fathers' sensitive parenting in infancy and toddlerhood and children's early executive functioning, as well as the contribution of maternal sensitive parenting. After accounting for the quality of concurrent and prior parental care, children's early cognitive ability, and other child and family factors, fathers' and mothers' sensitive and supportive parenting during play at 24 months predicted children's executive functioning at 3 years of age. In contrast, paternal parenting quality during play at 7 months did not make an independent contribution above that of maternal care, but the links between maternal sensitive and supportive parenting and executive functioning seemed to operate in similar ways during infancy and toddlerhood. These findings add to prior work on early experience and children's executive functioning, suggesting that both fathers and mothers play a distinct and complementary role in the development of these self-regulatory skills.

  8. Long-term effect of surface light scattering and glistenings of intraocular lenses on visual function.

    PubMed

    Hayashi, Ken; Hirata, Akira; Yoshida, Motoaki; Yoshimura, Koichi; Hayashi, Hideyuki

    2012-08-01

    To investigate the long-term effect of surface light scattering and glistenings of various intraocular lenses (IOLs) on visual function and optical aberrations after cataract surgery. Case-control study. Thirty-five eyes that underwent implantation of a hydrophobic acrylic, silicone, or polymethyl methacrylate (PMMA) IOL more than 10 years ago were recruited. The scattering light intensity of the surface and internal matrix of the optic was measured using Scheimpflug photography. Visual acuity (VA) was measured using VA charts, and contrast VA and that with glare (glare VA) were examined using a contrast sensitivity tester. Ocular higher-order aberrations (HOAs) were measured using a Hartmann-Shack aberrometer. Mean scattering light intensity of the surface and internal matrix of the optic was significantly higher in the acrylic group than in the silicone and PMMA groups (P < .0001). Mean uncorrected VA, photopic and mesopic contrast VA and glare VA, and HOAs did not differ significantly among groups, although mean corrected VA in the acrylic group was significantly better than that in the other groups (P = .0023). Scattering light intensity of the surface and internal matrix did not correlate with VA, contrast VA, or glare VA, and did not correlate with ocular and internal optic HOAs in the acrylic group. At more than 10 years postoperatively, visual function, including contrast sensitivity, and ocular HOAs were comparable among eyes that received acrylic, silicone, and PMMA IOLs. Surface scattering and glistenings with the acrylic IOLs were not significantly correlated with visual function and optical aberrations. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Subjective Visual Performance and Objective Optical Quality With Intraocular Lens Glistening and Surface Light Scattering.

    PubMed

    Luo, Furong; Bao, Xuan; Qin, Yingyan; Hou, Min; Wu, Mingxing

    2018-06-01

    To evaluate the long-term effect of glistenings and surface light scattering of intraocular lenses (IOLs) on visual and optical performance after cataract surgery. Pseudophakic eyes that underwent standard phacoemulsification and two types of hydrophobic acrylic spherical IOL implantation without complications for at least 5 years were included in this retrospective study. Participants were divided into the glistenings, surface light scattering, and control groups according to the current condition of the IOLs. Then participants received a follow-up examination including uncorrected and corrected distance visual acuity (UDVA and CDVA), contrast sensitivity, straylight, and intraocular higher order aberrations, as well as point spread function (PSF) and modulation transfer function (MTF). A total of 140 eyes were included in the study. UDVA, CDVA, and glare sensitivity were not significantly different among the three groups (P > .05). However, compared with the control group, the IOLs of the glistenings and surface light scattering groups were associated with significantly lower contrast sensitivity under no glare conditions. Furthermore, eye with glistenings exhibited the highest straylight value (P < .05), whereas no difference was found between the surface light scattering and control groups. In contrast to the control group, the spherical aberration increased and the mean values of PSF and MTF decreased in the glistenings and surface light scattering groups. Both glistenings and surface light scattering tend to impair subjective visual performance, such as contrast sensitivity, and potentially affect objective optical quality, including straylight, spherical aberration, PSF, and MTF. [J Refract Surg. 2018;34(6):372-378.]. Copyright 2018, SLACK Incorporated.

  10. Design and validation of a method for evaluation of interocular interaction.

    PubMed

    Lai, Xin Jie Angela; Alexander, Jack; Ho, Arthur; Yang, Zhikuan; He, Mingguang; Suttle, Catherine

    2012-02-01

    To design a simple viewing system allowing dichoptic masking, and to validate this system in adults and children with normal vision. A Trial Frame Apparatus (TFA) was designed to evaluate interocular interaction. This device consists of a trial frame, a 1 mm pinhole in front of the tested eye and a full or partial occluder in front of the non-tested eye. The difference in visual function in one eye between the full- and partial-occlusion conditions was termed the Interaction Index. In experiment 1, low-contrast acuity was measured in six adults using five types of partial occluder. Interaction Index was compared between these five, and the occluder showing the highest Index was used in experiment 2. In experiment 2, low-contrast acuity, contrast sensitivity, and alignment sensitivity were measured in the non-dominant eye of 45 subjects (15 older adults, 15 young adults, and 15 children), using the TFA and an existing well-validated device (shutter goggles) with full and partial occlusion of the dominant eye. These measurements were repeated on 11 subjects of each group using TFA in the partial-occlusion condition only. Repeatability of visual function measurements using TFA was assessed using the Bland-Altman method and agreement between TFA and goggles in terms of visual functions and interactions was assessed using the Bland-Altman method and t-test. In all three subject groups, the TFA showed a high level of repeatability in all visual function measurements. Contrast sensitivity was significantly poorer when measured using TFA than using goggles (p < 0.05). However, Interaction Index of all three visual functions showed acceptable agreement between TFA and goggles (p > 0.05). The TFA may provide an acceptable method for the study of some forms of dichoptic masking in populations where more complex devices (e.g., shutter goggles) cannot be used.

  11. Refractive Error and Visual Functions in Children with Special Needs Compared with the First Grade School Students in Oman

    PubMed Central

    Vora, Urmi; Khandekar, Rajiv; Natrajan, Sarvanan; Al-Hadrami, Khalfan

    2010-01-01

    Background: We evaluated the refractive status and visual function of children with special needs (other handicap) in 2010 and compared them with healthy 1st grade school students in Oman. Materials and Methods: This was a cohort study. Optometrists recorded vision using a logarithm of minimum angle of resolution (LogMAR) chart. Preferential looking method was used for testing 31 children. Cycloplegic refraction was performed on all children. Contrast sensitivity was tested using 2.5%, 10%, and 100% contrast charts. Ocular movement, alignment, and anterior segment were also assessed. A pediatrician reviewed the health records of all the children at the time of their enrollment in this study to determine if the child had been diagnosed with a systemic condition or syndromes. The visual functions were assessed by study investigators. We estimated the rates and the risk of different visual function defects in children with special needs. Result: The prevalence of refractive error in 70 children (4.7 ± 0.8 years) with special needs (group 1) and 175 normal healthy first grade students (group 2) were 58.5% and 2.9%, respectively. The risk of refractive error was significantly higher in children with special needs [relative risk, 48.1 (95% confidence interval, 17.54–131.8)]. Hyperopia (>1.00 D), myopia (≥ 1.00D) and astigmatism (≥ ±1.00 D) were found in 18.6%, 24.3%, and 27.1%, respectively, in group 1. Six children in this group had defective near vision. Sixteen (80%) children with Down syndrome had refractive error. Seven (50%) children with developmental disorder showed decreased contrast sensitivity. Conclusion: Prevalence of uncorrected refractive error was much higher in children with special needs. Prevalence of strabismus, nystagmus, and reduced contrast sensitivity was also higher in children with special needs. Early vision screening, visual function assessment, correction of refractive error, and frequent follow-up are recommended. PMID:21180428

  12. Oxygenation state and twilight vision at 2438 m.

    PubMed

    Connolly, Desmond M

    2011-01-01

    Under twilight viewing conditions, hypoxia, equivalent to breathing air at 3048 m (10,000 ft), compromises low contrast acuity, dynamic contrast sensitivity, and chromatic sensitivity. Selected past experiments have been repeated under milder hypoxia, equivalent to altitude exposure below 2438 m (8000 ft), to further define the influence of oxygenation state on mesopic vision. To assess photopic and mesopic visual function, 12 subjects each undertook three experiments using the Contrast Acuity Assessment test, the Frequency Doubling Perimeter, and the Color Assessment and Diagnosis (CAD) test. Experiments were conducted near sea level breathing 15.2% oxygen (balance nitrogen) and 100% oxygen, representing mild hypobaric hypoxia at 2438 m (8000 ft) and the benefit of supplementary oxygen, respectively. Oxygenation state was a statistically significant determinant of visual performance on all three visual parameters at mesopic, but not photopic, luminance. Mesopic sensitivity was greater with supplementary oxygen, but the magnitude of each hypoxic decrement was slight. Hypoxia elevated mesopic contrast acuity thresholds by approximately 4%; decreased mesopic dynamic contrast sensitivity by approximately 2 dB; and extended mean color ellipse axis length by approximately one CAD unit at mesopic luminance (that is, hypoxia decreased chromatic sensitivity). The results indicate that twilight vision may be susceptible to conditions of altered oxygenation at upper-to-mid mesopic luminance with relevance to contemporary night flying, including using night vision devices. Supplementary oxygen should be considered when optimal visual performance is mission-critical during flight above 2438 m (8000 ft) in dim light.

  13. Is vision function related to physical functional ability in older adults?

    PubMed

    West, Catherine G; Gildengorin, Ginny; Haegerstrom-Portnoy, Gunilla; Schneck, Marilyn E; Lott, Lori; Brabyn, John A

    2002-01-01

    To assess the relationship between a broad range of vision functions and measures of physical performance in older adults. Cross-sectional study. Population-based cohort of community-dwelling older adults, subset of an on-going longitudinal study. Seven hundred eighty-two adults aged 55 and older (65% of living eligible subjects) had subjective health measures and objective physical performance evaluated in 1989/91 and again in 1993/95 and a battery of vision functions tested in 1993/95. Comprehensive battery of vision tests (visual acuity, contrast sensitivity, effects of illumination level, contrast and glare on acuity, visual fields with and without attentional load, color vision, temporal sensitivity, and the impact of dimming light on walking ability) and physical function measures (self-reported mobility limitations and observed measures of walking, rising from a chair and tandem balance). The failure rate for all vision functions and physical performance measures increased exponentially with age. Standard high-contrast visual acuity and standard visual fields showed the lowest failure rates. Nonstandard vision tests showed much higher failure rates. Poor performance on many individual vision functions was significantly associated with particular individual measures of physical performance. Using constructed combination vision variables, significant associations were found between spatial vision, field integrity, binocularity and/or adaptation, and each of the functional outcomes. Vision functions other than standard visual acuity may affect day-to-day functioning of older adults. Additional studies of these other aspects of vision and how they can be treated or rehabilitated are needed to determine whether these aspects play a role in strategies for reducing disability in older adults.

  14. Contrast Sensitivity Perimetry and Clinical Measures of Glaucomatous Damage

    PubMed Central

    Swanson, William H.; Malinovsky, Victor E.; Dul, Mitchell W.; Malik, Rizwan; Torbit, Julie K.; Sutton, Bradley M.; Horner, Douglas G.

    2014-01-01

    ABSTRACT Purpose To compare conventional structural and functional measures of glaucomatous damage with a new functional measure—contrast sensitivity perimetry (CSP-2). Methods One eye each was tested for 51 patients with glaucoma and 62 age-similar control subjects using CSP-2, size III 24-2 conventional automated perimetry (CAP), 24-2 frequency-doubling perimetry (FDP), and retinal nerve fiber layer (RNFL) thickness. For superior temporal (ST) and inferior temporal (IT) optic disc sectors, defect depth was computed as amount below mean normal, in log units. Bland-Altman analysis was used to assess agreement on defect depth, using limits of agreement and three indices: intercept, slope, and mean difference. A criterion of p < 0.0014 for significance used Bonferroni correction. Results Contrast sensitivity perimetry-2 and FDP were in agreement for both sectors. Normal variability was lower for CSP-2 than for CAP and FDP (F > 1.69, p < 0.02), and Bland-Altman limits of agreement for patient data were consistent with variability of control subjects (mean difference, −0.01 log units; SD, 0.11 log units). Intercepts for IT indicated that CSP-2 and FDP were below mean normal when CAP was at mean normal (t > 4, p < 0.0005). Slopes indicated that, as sector damage became more severe, CAP defects for IT and ST deepened more rapidly than CSP-2 defects (t > 4.3, p < 0.0005) and RNFL defects for ST deepened more slowly than for CSP, FDP, and CAP. Mean differences indicated that FDP defects for ST and IT were on average deeper than RNFL defects, as were CSP-2 defects for ST (t > 4.9, p < 0.0001). Conclusions Contrast sensitivity perimetry-2 and FDP defects were deeper than CAP defects in optic disc sectors with mild damage and revealed greater residual function in sectors with severe damage. The discordance between different measures of glaucomatous damage can be accounted for by variability in people free of disease. PMID:25259758

  15. Contrast sensitivity perimetry and clinical measures of glaucomatous damage.

    PubMed

    Swanson, William H; Malinovsky, Victor E; Dul, Mitchell W; Malik, Rizwan; Torbit, Julie K; Sutton, Bradley M; Horner, Douglas G

    2014-11-01

    To compare conventional structural and functional measures of glaucomatous damage with a new functional measure-contrast sensitivity perimetry (CSP-2). One eye each was tested for 51 patients with glaucoma and 62 age-similar control subjects using CSP-2, size III 24-2 conventional automated perimetry (CAP), 24-2 frequency-doubling perimetry (FDP), and retinal nerve fiber layer (RNFL) thickness. For superior temporal (ST) and inferior temporal (IT) optic disc sectors, defect depth was computed as amount below mean normal, in log units. Bland-Altman analysis was used to assess agreement on defect depth, using limits of agreement and three indices: intercept, slope, and mean difference. A criterion of p < 0.0014 for significance used Bonferroni correction. Contrast sensitivity perimetry-2 and FDP were in agreement for both sectors. Normal variability was lower for CSP-2 than for CAP and FDP (F > 1.69, p < 0.02), and Bland-Altman limits of agreement for patient data were consistent with variability of control subjects (mean difference, -0.01 log units; SD, 0.11 log units). Intercepts for IT indicated that CSP-2 and FDP were below mean normal when CAP was at mean normal (t > 4, p < 0.0005). Slopes indicated that, as sector damage became more severe, CAP defects for IT and ST deepened more rapidly than CSP-2 defects (t > 4.3, p < 0.0005) and RNFL defects for ST deepened more slowly than for CSP, FDP, and CAP. Mean differences indicated that FDP defects for ST and IT were on average deeper than RNFL defects, as were CSP-2 defects for ST (t > 4.9, p < 0.0001). Contrast sensitivity perimetry-2 and FDP defects were deeper than CAP defects in optic disc sectors with mild damage and revealed greater residual function in sectors with severe damage. The discordance between different measures of glaucomatous damage can be accounted for by variability in people free of disease.

  16. Effect of Povidone Iodine 5% on the Cornea, Vision, and Subjective Comfort.

    PubMed

    Ridder, William H; Oquindo, Caren; Dhamdhere, Kavita; Burke, James

    2017-07-01

    To determine the effects of povidone iodine 5% (Betadine 5%) applied to the eye on visual function, corneal integrity, and subjective complaints. Ten subjects were chosen to participate in this study (average age 40.6 ± 19.6; age range 22-68). LogMAR acuity, contrast sensitivity, corneal fluorescein staining, and subjective complaints were measured before and after 60 μl of Betadine 5% or saline were applied to one eye (eligibility visit, baseline, 5, 30, and 60 minutes and 4 and 24 hours post-application). Contrast sensitivity at 14 cpd was determined with a spatial two-alternative, forced choice procedure (Beethoven software). The National Eye Institute (NEI) grid pattern was used to grade corneal staining with sodium fluorescein. To avoid the detrimental effects of sodium fluorescein administration on functional vision, the corneal staining baseline was measured at the eligibility visit. Subjective complaints were monitored using the Schein dry eye questionnaire. The data were analyzed with an ANOVA. Saline administration did not alter logMAR acuity, contrast sensitivity, corneal fluorescein staining, or subjective complaints at any visit. Betadine administration significantly reduced the logMAR acuity, compared to baseline and the saline data, at the 30- and 60-minute visits (all P values <.05). The contrast sensitivity was significantly reduced compared to the baseline and the saline results at 5, 30, and 60 minutes after Betadine application (all P values <.05). The Betadine significantly increased the Schein questionnaire score, compared both to baseline and the saline data, at the 1- and 4-hour visits (all P values <.05). Total corneal staining and the maximum NEI sector staining were significantly different from baseline and from the saline results at every visit (all P values <.05). Betadine 5% application significantly decreases epithelial integrity of the cornea, decreases functional vision, and increases subjective complaints.

  17. Amblyopia in Astigmatic Children: Patterns of Deficits

    PubMed Central

    Harvey, Erin M.; Dobson, Velma; Miller, Joseph M.; Clifford-Donaldson, Candice E.

    2007-01-01

    Neural changes that result from disruption of normal visual experience during development are termed amblyopia. To characterize visual deficits specific to astigmatism-related amblyopia, we compared best-corrected visual performance in 330 astigmatic and 475 non-astigmatic kindergarten through 6th grade children. Astigmatism was associated with deficits in letter, grating and vernier acuity, high and middle spatial frequency contrast sensitivity, and stereoacuity. Although grating acuity, vernier acuity, and contrast sensitivity were reduced across stimulus orientation, astigmats demonstrated orientation-dependent deficits (meridional amblyopia) only for grating acuity. Astigmatic children are at risk for deficits across a range of visual functions. PMID:17184807

  18. Optical functional performance of the osteo-odonto-keratoprosthesis.

    PubMed

    Lee, Richard M H; Ong, Gek L; Lam, Fook Chang; White, Joy; Crook, David; Liu, Christopher S C; Hull, Chris C

    2014-10-01

    The aim of this study was to evaluate optical and visual functional performance of the osteo-odonto-keratoprosthesis (OOKP). Optical design and analysis was performed with customized optical design software. Nine patients with implanted OOKP devices and 9 age-matched control patients were assessed. Contrast sensitivity was assessed and glare effect was measured with a brightness acuity test. All OOKP patients underwent kinetic Goldmann perimetry and wavefront aberrometry and completed the National Eye Institute Visual Function Questionnaire-25 (NEI VFQ-25). Optical analysis showed that the optical cylinder is near diffraction-limited. A reduction in median visual acuity (VA) with increasing glare settings was observed from 0.04 logMAR (without glare) to 0.20 logMAR (with glare at "high" setting) and significantly reduced statistically when compared with the control group at all levels of glare (P < 0.05). Contrast sensitivity was significantly reduced when compared with age-matched controls at medium and high spatial frequencies (P < 0.05). Median Goldmann perimetry was 65 degrees (interquartile range, 64-74 degrees; V-4e isopters) and 69 degrees excluding 2 glaucomatous subjects. Several vision-related NEI VFQ-25 subscales correlated significantly with VA at various brightness acuity test levels and contrast sensitivity at medium spatial frequencies, including dependency, general vision, near activities and distance activities. The OOKP optical cylinder provides patients with a good level of VA that is significantly reduced by glare. We have shown in vivo that updates to the optical cylinder design have improved the patient's field of view. Reduction of glare and refinement of cylinder alignment methods may further improve visual function and patient satisfaction.

  19. Improving Sensitivity in Ultrasound Molecular Imaging by Tailoring Contrast Agent Size Distribution: In Vivo Studies

    PubMed Central

    Streeter, Jason E.; Gessner, Ryan; Miles, Iman; Dayton, Paul A.

    2010-01-01

    Molecular imaging with ultrasound relies on microbubble contrast agents (MCAs) selectively adhering to a ligand-specific target. Prior studies have shown that only small quantities of microbubbles are retained at their target sites, therefore, enhancing contrast sensitivity to low concentrations of microbubbles is essential to improve molecular imaging techniques. In order to assess the effect of MCA diameter on imaging sensitivity, perfusion and molecular imaging studies were performed with microbubbles of varying size distributions. To assess signal improvement and MCA circulation time as a function of size and concentration, blood perfusion was imaged in rat kidneys using nontargeted size-sorted MCAs with a Siemens Sequoia ultrasound system (Siemans, Mountain View, CA) in cadence pulse sequencing (CPS) mode. Molecular imaging sensitivity improvements were studied with size-sorted αvβ3-targeted bubbles in both fibrosarcoma and R3230 rat tumor models. In perfusion imaging studies, video intensity and contrast persistence was ≈8 times and ≈3 times greater respectively, for “sorted 3-micron” MCAs (diameter, 3.3 ± 1.95 μm) when compared to “unsorted” MCAs (diameter, 0.9 ± 0.45 μm) at low concentrations. In targeted experiments, application of sorted 3-micron MCAs resulted in a ≈20 times video intensity increase over unsorted populations. Tailoring size-distributions results in substantial imaging sensitivity improvement over unsorted populations, which is essential in maximizing sensitivity to small numbers of MCAs for molecular imaging. PMID:20236606

  20. Subchronic Toluene Exposure alters Retinal Function in Long Evans Rats: Experimental Evidence Supporting Observations from Studies of Exposed Humans.

    EPA Science Inventory

    Studies of humans chronically exposed to volatile organic solvents commonly report impaired visual functions, including low contrast sensitivity and reduced color discrimination. These reports have been controversial, however, in part due to a lack of confirmation from controlled...

  1. Model of visual contrast gain control and pattern masking

    NASA Technical Reports Server (NTRS)

    Watson, A. B.; Solomon, J. A.

    1997-01-01

    We have implemented a model of contrast gain and control in human vision that incorporates a number of key features, including a contrast sensitivity function, multiple oriented bandpass channels, accelerating nonlinearities, and a devisive inhibitory gain control pool. The parameters of this model have been optimized through a fit to the recent data that describe masking of a Gabor function by cosine and Gabor masks [J. M. Foley, "Human luminance pattern mechanisms: masking experiments require a new model," J. Opt. Soc. Am. A 11, 1710 (1994)]. The model achieves a good fit to the data. We also demonstrate how the concept of recruitment may accommodate a variant of this model in which excitatory and inhibitory paths have a common accelerating nonlinearity, but which include multiple channels tuned to different levels of contrast.

  2. Influence of retinopathy on the achromatic and chromatic vision of patients with type 2 diabetes

    PubMed Central

    2014-01-01

    Background Luminance contrast sensitivity and colour vision are considered to have great predictive value in the evaluation of type 2 diabetic retinopathy. However, these two visual characteristics have seldom been investigated in the same group of patients. In the present study we measured contrast sensitivity and colour vision in a group of patients with type 2 diabetes and correlated the results with estimates of common metabolic markers for the disease. A subgroup of the patients had no clinical signs of retinopathy. Methods The vision of 27 patients (n = 50 eyes) with type 2 diabetes, with retinopathy (n = 20 eyes), or without retinopathy (n = 30 eyes) were evaluated using two psychophysical tests, the Farnsworth–Munsell 100 hue test (FM 100), and measurements of the luminance contrast sensitivity at 11 spatial frequencies. The results were compared with measurements obtained from an age-matched control group (n = 32), and were correlated with the level of glycated haemoglobin, glycaemic level, and time of disease onset. Signs of retinopathy were identified during the ophthalmological examinations. Results Contrast sensitivity and colour vision impairments were present at different levels in diabetes patients. Eyes with retinopathy showed more severe vision loss than eyes without retinopathy. The FM 100 test was more sensitive for separation of patients from controls. Colour vision loss had no colour axes preference. The contrast sensitivity test appeared to have some advantage in differentiating patients with retinopathy from patients without retinopathy. Conclusions Both methods can be useful to follow the visual function of diabetic patients and should be used together to discriminate patients from controls, as well as to identify early signs of retinal damage. PMID:25174264

  3. Diversity in spatial scope of contrast adaptation among mouse retinal ganglion cells.

    PubMed

    Khani, Mohammad Hossein; Gollisch, Tim

    2017-12-01

    Retinal ganglion cells adapt to changes in visual contrast by adjusting their response kinetics and sensitivity. While much work has focused on the time scales of these adaptation processes, less is known about the spatial scale of contrast adaptation. For example, do small, localized contrast changes affect a cell's signal processing across its entire receptive field? Previous investigations have provided conflicting evidence, suggesting that contrast adaptation occurs either locally within subregions of a ganglion cell's receptive field or globally over the receptive field in its entirety. Here, we investigated the spatial extent of contrast adaptation in ganglion cells of the isolated mouse retina through multielectrode-array recordings. We applied visual stimuli so that ganglion cell receptive fields contained regions where the average contrast level changed periodically as well as regions with constant average contrast level. This allowed us to analyze temporal stimulus integration and sensitivity separately for stimulus regions with and without contrast changes. We found that the spatial scope of contrast adaptation depends strongly on cell identity, with some ganglion cells displaying clear local adaptation, whereas others, in particular large transient ganglion cells, adapted globally to contrast changes. Thus, the spatial scope of contrast adaptation in mouse retinal ganglion cells appears to be cell-type specific. This could reflect differences in mechanisms of contrast adaptation and may contribute to the functional diversity of different ganglion cell types. NEW & NOTEWORTHY Understanding whether adaptation of a neuron in a sensory system can occur locally inside the receptive field or whether it always globally affects the entire receptive field is important for understanding how the neuron processes complex sensory stimuli. For mouse retinal ganglion cells, we here show that both local and global contrast adaptation exist and that this diversity in spatial scope can contribute to the functional diversity of retinal ganglion cell types. Copyright © 2017 the American Physiological Society.

  4. Diversity in spatial scope of contrast adaptation among mouse retinal ganglion cells

    PubMed Central

    Khani, Mohammad Hossein

    2017-01-01

    Retinal ganglion cells adapt to changes in visual contrast by adjusting their response kinetics and sensitivity. While much work has focused on the time scales of these adaptation processes, less is known about the spatial scale of contrast adaptation. For example, do small, localized contrast changes affect a cell’s signal processing across its entire receptive field? Previous investigations have provided conflicting evidence, suggesting that contrast adaptation occurs either locally within subregions of a ganglion cell’s receptive field or globally over the receptive field in its entirety. Here, we investigated the spatial extent of contrast adaptation in ganglion cells of the isolated mouse retina through multielectrode-array recordings. We applied visual stimuli so that ganglion cell receptive fields contained regions where the average contrast level changed periodically as well as regions with constant average contrast level. This allowed us to analyze temporal stimulus integration and sensitivity separately for stimulus regions with and without contrast changes. We found that the spatial scope of contrast adaptation depends strongly on cell identity, with some ganglion cells displaying clear local adaptation, whereas others, in particular large transient ganglion cells, adapted globally to contrast changes. Thus, the spatial scope of contrast adaptation in mouse retinal ganglion cells appears to be cell-type specific. This could reflect differences in mechanisms of contrast adaptation and may contribute to the functional diversity of different ganglion cell types. NEW & NOTEWORTHY Understanding whether adaptation of a neuron in a sensory system can occur locally inside the receptive field or whether it always globally affects the entire receptive field is important for understanding how the neuron processes complex sensory stimuli. For mouse retinal ganglion cells, we here show that both local and global contrast adaptation exist and that this diversity in spatial scope can contribute to the functional diversity of retinal ganglion cell types. PMID:28904106

  5. Functional considerations in evaluation and treatment of the client with low vision.

    PubMed

    Lampert, J; Lapolice, D J

    1995-10-01

    In evaluating and treating clients who have low vision, the occupational therapist must consider factors in addition to typical measures of the client's visual acuity, field loss, and oculomotor control. It is important to consider the functional implications of the client's ocular pathology, including illumination needs, contrast sensitivity, sensitivity to glare, and need for magnification as well as environmental factors such as the amount of pattern in a visual task, the amount of lighting and contrast available, and the conditions under which the task is performed. These factors are all relevant to occupational therapy low vision rehabilitation because each may influence the way in which a client uses his or her residual vision and achieves successful adaptation. This article provides an overview of these factors and presents a suggested protocol for evaluation of the client with low vision.

  6. Anodal transcranial direct current stimulation transiently improves contrast sensitivity and normalizes visual cortex activation in individuals with amblyopia.

    PubMed

    Spiegel, Daniel P; Byblow, Winston D; Hess, Robert F; Thompson, Benjamin

    2013-10-01

    Amblyopia is a neurodevelopmental disorder of vision that is associated with abnormal patterns of neural inhibition within the visual cortex. This disorder is often considered to be untreatable in adulthood because of insufficient visual cortex plasticity. There is increasing evidence that interventions that target inhibitory interactions within the visual cortex, including certain types of noninvasive brain stimulation, can improve visual function in adults with amblyopia. We tested the hypothesis that anodal transcranial direct current stimulation (a-tDCS) would improve visual function in adults with amblyopia by enhancing the neural response to inputs from the amblyopic eye. Thirteen adults with amblyopia participated and contrast sensitivity in the amblyopic and fellow fixing eye was assessed before, during and after a-tDCS or cathodal tDCS (c-tDCS). Five participants also completed a functional magnetic resonance imaging (fMRI) study designed to investigate the effect of a-tDCS on the blood oxygen level-dependent response within the visual cortex to inputs from the amblyopic versus the fellow fixing eye. A subgroup of 8/13 participants showed a transient improvement in amblyopic eye contrast sensitivity for at least 30 minutes after a-tDCS. fMRI measurements indicated that the characteristic cortical response asymmetry in amblyopes, which favors the fellow eye, was reduced by a-tDCS. These preliminary results suggest that a-tDCS deserves further investigation as a potential tool to enhance amblyopia treatment outcomes in adults.

  7. Patterns of Sensitivity to Emotion in Children with Williams Syndrome and Autism: Relations between Autonomic Nervous System Reactivity and Social Functioning

    ERIC Educational Resources Information Center

    Järvinen, Anna; Ng, Rowena; Crivelli, Davide; Neumann, Dirk; Grichanik, Mark; Arnold, Andrew J.; Lai, Philip; Trauner, Doris; Bellugi, Ursula

    2015-01-01

    Williams syndrome (WS) and autism spectrum disorder (ASD) are associated with atypical social-emotional functioning. Affective visual stimuli were used to assess autonomic reactivity and emotion identification, and the social responsiveness scale was used to determine the level social functioning in children with WS and ASD contrasted with typical…

  8. Visual determinants of reduced performance on the Stroop color-word test in normal aging individuals.

    PubMed

    van Boxtel, M P; ten Tusscher, M P; Metsemakers, J F; Willems, B; Jolles, J

    2001-10-01

    It is unknown to what extent the performance on the Stroop color-word test is affected by reduced visual function in older individuals. We tested the impact of common deficiencies in visual function (reduced distant and close acuity, reduced contrast sensitivity, and color weakness) on Stroop performance among 821 normal individuals aged 53 and older. After adjustment for age, sex, and educational level, low contrast sensitivity was associated with more time needed on card I (word naming), red/green color weakness with slower card 2 performance (color naming), and reduced distant acuity with slower performance on card 3 (interference). Half of the age-related variance in speed performance was shared with visual function. The actual impact of reduced visual function may be underestimated in this study when some of this age-related variance in Stroop performance is mediated by visual function decrements. It is suggested that reduced visual function has differential effects on Stroop performance which need to be accounted for when the Stroop test is used both in research and in clinical settings. Stroop performance measured from older individuals with unknown visual status should be interpreted with caution.

  9. Describing contrast across scales

    NASA Astrophysics Data System (ADS)

    Syed, Sohaib Ali; Iqbal, Muhammad Zafar; Riaz, Muhammad Mohsin

    2017-06-01

    Due to its sensitive nature against illumination and noise distributions, contrast is not widely used for image description. On the contrary, the human perception of contrast along different spatial frequency bandwidths provides a powerful discriminator function that can be modeled in a robust manner against local illumination. Based upon this observation, a dense local contrast descriptor is proposed and its potential in different applications of computer vision is discussed. Extensive experiments reveal that this simple yet effective description performs well in comparison with state of the art image descriptors. We also show the importance of this description in multiresolution pansharpening framework.

  10. Visual dysfunction in Parkinson’s disease

    PubMed Central

    Weil, Rimona S.; Schrag, Anette E.; Warren, Jason D.; Crutch, Sebastian J.; Lees, Andrew J.; Morris, Huw R.

    2016-01-01

    Patients with Parkinson’s disease have a number of specific visual disturbances. These include changes in colour vision and contrast sensitivity and difficulties with complex visual tasks such as mental rotation and emotion recognition. We review changes in visual function at each stage of visual processing from retinal deficits, including contrast sensitivity and colour vision deficits to higher cortical processing impairments such as object and motion processing and neglect. We consider changes in visual function in patients with common Parkinson’s disease-associated genetic mutations including GBA and LRRK2. We discuss the association between visual deficits and clinical features of Parkinson’s disease such as rapid eye movement sleep behavioural disorder and the postural instability and gait disorder phenotype. We review the link between abnormal visual function and visual hallucinations, considering current models for mechanisms of visual hallucinations. Finally, we discuss the role of visuo-perceptual testing as a biomarker of disease and predictor of dementia in Parkinson’s disease. PMID:27412389

  11. Visual Multipoles And The Assessment Of Visual Sensitivity To Displayed Images

    NASA Astrophysics Data System (ADS)

    Klein, Stanley A.

    1989-08-01

    The contrast sensitivity function (CSF) is widely used to specify the sensitivity of the visual system. Each point of the CSF specifies the amount of contrast needed to detect a sinusoidal grating of a given spatial frequency. This paper describes a set of five mathematically related visual patterns, called "multipoles," that should replace the CSF for measuring visual performance. The five patterns (ramp, edge, line, dipole and quadrupole) are localized in space rather than being spread out as sinusoidal gratings. The multipole sensitivity of the visual system provides an alternative characterization that complements the CSF in addition to offering several advantages. This paper provides an overview of the properties and uses of the multipole stimuli. This paper is largely a summary of several unpublished manuscripts with excerpts from them. Derivations and full references are omitted here. Please write me if you would like the full manuscripts.

  12. Keeping Older Adults with Vision Loss Safe: Chronic Conditions and Comorbidities that Influence Functional Mobility

    ERIC Educational Resources Information Center

    Riddering, Anne T.

    2008-01-01

    Age-related macular degeneration (AMD) is a leading cause of vision loss in Americans aged 60 and older. The loss of central vision from AMD can decrease visual acuity, contrast sensitivity, glare sensitivity, color discrimination, and the ability to adapt to changes in lighting conditions. Older adults with vision loss often have other chronic,…

  13. Temporal dynamics of contrast gain in single cells of the cat striate cortex.

    PubMed

    Bonds, A B

    1991-03-01

    The response amplitude of cat striate cortical cells is usually reduced after exposure to high-contrast stimuli. The temporal characteristics and contrast sensitivity of this phenomenon were explored by stimulating cortical cells with drifting gratings in which contrast sequentially incremented and decremented in stepwise fashion over time. All responses showed a clear hysteresis, in which contrast gain dropped on average 0.36 log unit and then returned to baseline values within 60 s. Noticeable gain adjustments were seen in as little as 3 s and with peak contrasts as low as 3%. Contrast adaptation was absent in responses from LGN cells. Adaptation was found to depend on temporal frequency of stimulation, with greater and more rapid adaptation at higher temporal frequencies. Two different tests showed that the mechanism controlling response reduction was influenced primarily by stimulus contrast rather than response amplitude. These results support the existence of a rapid and sensitive cortically based system that normalizes the output of cortical cells as a function of local mean contrast. Control of the adaptation appears to arise at least in part across a population of cells, which is consistent with the idea that the gain control serves to limit the information converging from many cells onto subsequent processing areas.

  14. Magnetic relaxometry as applied to sensitive cancer detection and localization

    DOE PAGES

    De Haro, Leyma P.; Karaulanov, Todor; Vreeland, Erika C.; ...

    2015-06-02

    Abstract Here we describe superparamagnetic relaxometry (SPMR), a technology that utilizes highly sensitive magnetic sensors and superparamagnetic nanoparticles for cancer detection. Using SPMR, we sensitively and specifically detect nanoparticles conjugated to biomarkers for various types of cancer. SPMR offers high contrast In SPMR measurements, a brief magnetizing pulse is used to align superparamagnetic nanoparticles of a discrete size. Following the pulse, an array of superconducting quantum interference detectors (SQUID) sensors detect the decaying magnetization field. NP size is chosen so that, when bound, the induced field decays in seconds. They are functionalized with specific biomarkers and incubated with cancer cellsmore » As a result, superparamagnetic NPs developed here have small size dispersion. Cell incubation studies measure specificity for different cell lines and antibodies with very high contrast.« less

  15. Alemtuzumab improves contrast sensitivity in patients with relapsing–remitting multiple sclerosis

    PubMed Central

    Galetta, Steven L; Palmer, Jeffrey; Margolin, David H; Rizzo, Marco; Bilbruck, John; Balcer, Laura J

    2013-01-01

    Background: Alemtuzumab is a monoclonal antibody directed against CD52 that depletes T and B lymphocytes. Objective: To evaluate the treatment effect of alemtuzumab on low-contrast vision in relapsing–remitting multiple sclerosis (RRMS) patients. Methods: This was a pre-defined exploratory analysis within a randomized, rater-blinded trial (CAMMS223) that was run at 49 academic medical centers in the US and in Europe. Patients with untreated, early, RRMS (McDonald, n = 334) were randomized 1:1:1 to subcutaneous interferon beta-1a (IFNB-1a), or alemtuzumab 12 mg or 24 mg. Visual contrast sensitivity was measured for each eye at baseline and quarterly, with Pelli-Robson charts. Results: The eyes of patients in the pooled alemtuzumab group (versus IFNB-1a) had a greater than 2-fold higher rate of both 3-month and 6-month sustained visual improvement, of at least 0.3 log units (2 triplets, 6 letters) (At 3 months the hazard ratio (HR) = 2.26; CI = 1.19 to 4.31; P = 0.013; and at 6 months the HR = 2.44; CI =1.16 to 5.15; P = 0.019), and they had a lower risk of 3- and 6-month sustained worsening of at least 0.15 log units (1 triplet, 3 letters) (At 3 months the HR = 0.58; CI = 0.38 to 0.89; P = 0.012; and at 6 months HR = 0.55; CI=0.35 to 0.87; P = 0.010). Over the 36-month study period, the eyes of patients in the pooled alemtuzumab group improved in mean contrast sensitivity to a greater extent than those in the IFNB-1a group (0.080 log units versus 0.038 log units; P = 0.0102). Conclusions: Alemtuzumab was associated with a greater chance of improved contrast sensitivity in patients with RRMS and may delay the worsening of visual function. Contrast sensitivity testing was sensitive to treatment effects, even within an active comparator study design. These results support the validity of low-contrast vision testing as a clinical outcome in MS trials. PMID:23459567

  16. Spatial noise and threshold contrasts in LCD displays

    NASA Astrophysics Data System (ADS)

    Roehrig, Hans; Krupinski, Elizabeth A.; Chawla, Amarpreet S.; Fan, Jiahua; Gandhi, Kunal

    2003-05-01

    This paper presents the results of initial physical and psycho-physical evaluations of the noise of high resolution LCDs. 5 LCDs were involved, having 4 different pixel structures. Spatial as well as temporal noise was physically measured with the aid of a high-performance CCD camera. Human contrast sensitivity in the presence of spatial noise was determined psycho-physically using periodic stimuli (square-wave patterns) as well as aperiodic stimuli (squares). For the measurements of the human contrast sensitivity, all LCDs were calibrated to the DICOM 14 Grayscale Standard Display Function (GSDF). The results demonstrate that spatial noise is the dominant noise in all LCDs, while temporal noise is insignificant and plays only a minor part. The magnitude of spatial noise of LCDs is in the range between that of CRTs with a P104 and that of CRTs with a P45. Of particular importance with respect to LCD noise is the contribution of the pixel structure to the Noise Power Spectrum, which shows up as sharp spikes at spatial frequencies beyond the LCDs" Nyquist frequency. The paper does not offer any clues about the importance of these spikes on the human contrast sensitivity.

  17. Simulating visibility under reduced acuity and contrast sensitivity.

    PubMed

    Thompson, William B; Legge, Gordon E; Kersten, Daniel J; Shakespeare, Robert A; Lei, Quan

    2017-04-01

    Architects and lighting designers have difficulty designing spaces that are accessible to those with low vision, since the complex nature of most architectural spaces requires a site-specific analysis of the visibility of mobility hazards and key landmarks needed for navigation. We describe a method that can be utilized in the architectural design process for simulating the effects of reduced acuity and contrast on visibility. The key contribution is the development of a way to parameterize the simulation using standard clinical measures of acuity and contrast sensitivity. While these measures are known to be imperfect predictors of visual function, they provide a way of characterizing general levels of visual performance that is familiar to both those working in low vision and our target end-users in the architectural and lighting-design communities. We validate the simulation using a letter-recognition task.

  18. Simulating Visibility Under Reduced Acuity and Contrast Sensitivity

    PubMed Central

    Thompson, William B.; Legge, Gordon E.; Kersten, Daniel J.; Shakespeare, Robert A.; Lei, Quan

    2017-01-01

    Architects and lighting designers have difficulty designing spaces that are accessible to those with low vision, since the complex nature of most architectural spaces requires a site-specific analysis of the visibility of mobility hazards and key landmarks needed for navigation. We describe a method that can be utilized in the architectural design process for simulating the effects of reduced acuity and contrast on visibility. The key contribution is the development of a way to parameterize the simulation using standard clinical measures of acuity and contrast sensitivity. While these measures are known to be imperfect predictors of visual function, they provide a way of characterizing general levels of visual performance that is familiar to both those working in low vision and our target end-users in the architectural and lighting design communities. We validate the simulation using a letter recognition task. PMID:28375328

  19. Punctal plugs versus artificial tears for treating dry eye: a comparative observation of their effects on contrast sensitivity.

    PubMed

    Qiu, Weiqiang; Liu, Ziyuan; Zhang, Zhihong; Ao, Mingxin; Li, Xuemin; Wang, Wei

    2012-01-01

    This study aimed to compare the effects of treatment with punctal plugs versus artificial tears on visual function and tear film stability for dry eye. A total of 56 consecutive eyes of 28 dry eye patients observed at our clinic from May to October in 2009 were divided into two groups. One group (32 eyes of 16 patients) was treated with artificial tears, and punctal plugs were used in the other group (24 eyes of 12 patients). A questionnaire was used in these patients before treatment and was repeated 2 weeks after treatment. Fluorescent staining for tear film break-up time (BUT), the Schirmer test I (STI), and contrast sensitivity was performed at the same time. The questionnaire indicated that all patients complained about the uncomfortable symptoms associated with dry eye. These symptoms were relieved after the application of artificial tears or punctal plugs, and there was no significant difference between these two groups. We found that the corneal fluorescent staining disappeared after treatment. The BUT was improved significantly after treatment in both groups, but the improvement was greater in patients who received punctal plugs than those that received artificial tears. There was no remarkable change in the STI in the artificial tears group, but a significant change was observed in the punctal plugs group. The contrast sensitivities were greatly improved in simulated daylight, night, and glare disability conditions after treatment with artificial tears and punctal plugs. However, the changes in contrast sensitivity did not significantly differ between groups. Both artificial tears and punctal plugs relieved dry eye symptoms, repaired corneal lesions, enhanced tear film stability, and improved contrast sensitivity. Punctal plugs could improve tear film stability and elongate the BUT better than artificial tears.

  20. Gadolinium-based magnetic resonance imaging contrast agents in interventional radiology.

    PubMed

    Atar, Eli

    2004-07-01

    Gadolinium-based agents are widely used in magnetic resonance imaging as contrast agents. These agents are radio-opaque enough for diagnostic imaging of the vascular tree by using digitally subtracted images as well as for imaging of the biliary system and the urinary tract. The recommended doses for gadolinium do not impair renal function or cause adverse reactions in patients with iodine sensitivity; thus patients with such conditions can safely undergo diagnostic angiography, either by MRI angiography or by catheterization using gadolinium as contrast agent, for diagnostic and therapeutic purposes.

  1. Magnetomotive Molecular Nanoprobes

    PubMed Central

    John, Renu; Boppart, Stephen A.

    2012-01-01

    Tremendous developments in the field of biomedical imaging in the past two decades have resulted in the transformation of anatomical imaging to molecular-specific imaging. The main approaches towards imaging at a molecular level are the development of high resolution imaging modalities with high penetration depths and increased sensitivity, and the development of molecular probes with high specificity. The development of novel molecular contrast agents and their success in molecular optical imaging modalities have lead to the emergence of molecular optical imaging as a more versatile and capable technique for providing morphological, spatial, and functional information at the molecular level with high sensitivity and precision, compared to other imaging modalities. In this review, we discuss a new class of dynamic contrast agents called magnetomotive molecular nanoprobes for molecular-specific imaging. Magnetomotive agents are superparamagnetic nanoparticles, typically iron-oxide, that are physically displaced by the application of a small modulating external magnetic field. Dynamic phase-sensitive position measurements are performed using any high resolution imaging modality, including optical coherence tomography (OCT), ultrasonography, or magnetic resonance imaging (MRI). The dynamics of the magnetomotive agents can be used to extract the biomechanical tissue properties in which the nanoparticles are bound, and the agents can be used to deliver therapy via magnetomotive displacements to modulate or disrupt cell function, or hyperthermia to kill cells. These agents can be targeted via conjugation to antibodies, and in vivo targeted imaging has been shown in a carcinogen-induced rat mammary tumor model. The iron-oxide nanoparticles also exhibit negative T2 contrast in MRI, and modulations can produce ultrasound imaging contrast for multimodal imaging applications. PMID:21517766

  2. Making perceptual learning practical to improve visual functions.

    PubMed

    Polat, Uri

    2009-10-01

    Task-specific improvement in performance after training is well established. The finding that learning is stimulus-specific and does not transfer well between different stimuli, between stimulus locations in the visual field, or between the two eyes has been used to support the notion that neurons or assemblies of neurons are modified at the earliest stage of cortical processing. However, a debate regarding the proposed mechanism underlying perceptual learning is an ongoing issue. Nevertheless, generalization of a trained task to other functions is an important key, for both understanding the neural mechanisms and the practical value of the training. This manuscript describes a structured perceptual learning method that previously used (amblyopia, myopia) and a novel technique and results that were applied for presbyopia. In general, subjects were trained for contrast detection of Gabor targets under lateral masking conditions. Training improved contrast sensitivity and diminished the lateral suppression when it existed (amblyopia). The improvement was transferred to unrelated functions such as visual acuity. The new results of presbyopia show substantial improvement of the spatial and temporal contrast sensitivity, leading to improved processing speed of target detection as well as reaction time. Consequently, the subjects, who were able to eliminate the need for reading glasses, benefited. Thus, here we show that the transfer of functions indicates that the specificity of improvement in the trained task can be generalized by repetitive practice of target detection, covering a sufficient range of spatial frequencies and orientations, leading to an improvement in unrelated visual functions. Thus, perceptual learning can be a practical method to improve visual functions in people with impaired or blurred vision.

  3. Eccentricity mapping of the human visual cortex to evaluate temporal dynamics of functional T1ρ mapping.

    PubMed

    Heo, Hye-Young; Wemmie, John A; Johnson, Casey P; Thedens, Daniel R; Magnotta, Vincent A

    2015-07-01

    Recent experiments suggest that T1 relaxation in the rotating frame (T(1ρ)) is sensitive to metabolism and can detect localized activity-dependent changes in the human visual cortex. Current functional magnetic resonance imaging (fMRI) methods have poor temporal resolution due to delays in the hemodynamic response resulting from neurovascular coupling. Because T(1ρ) is sensitive to factors that can be derived from tissue metabolism, such as pH and glucose concentration via proton exchange, we hypothesized that activity-evoked T(1ρ) changes in visual cortex may occur before the hemodynamic response measured by blood oxygenation level-dependent (BOLD) and arterial spin labeling (ASL) contrast. To test this hypothesis, functional imaging was performed using T(1ρ), BOLD, and ASL in human participants viewing an expanding ring stimulus. We calculated eccentricity phase maps across the occipital cortex for each functional signal and compared the temporal dynamics of T(1ρ) versus BOLD and ASL. The results suggest that T(1ρ) changes precede changes in the two blood flow-dependent measures. These observations indicate that T(1ρ) detects a signal distinct from traditional fMRI contrast methods. In addition, these findings support previous evidence that T(1ρ) is sensitive to factors other than blood flow, volume, or oxygenation. Furthermore, they suggest that tissue metabolism may be driving activity-evoked T(1ρ) changes.

  4. Vision and Intelligence at Age 83 in the Lothian Birth Cohort 1921

    ERIC Educational Resources Information Center

    Henderson, Ross D.; Allerhand, Michael; Patton, Niall; Pattie, Alison; Gow, Alan J.; Dhillon, Baljean; Starr, John M.; Deary, Ian J.

    2011-01-01

    The extent to which visual function, measured as near and distant visual acuity and contrast sensitivity, is correlated with concurrently measured cognitive function and prior intellectual ability was investigated in a narrow age range group known as the Lothian Birth Cohort of 1921 (LBC1921). Participants were aged approximately 83 years at the…

  5. Visual functions and disability in diabetic retinopathy patients

    PubMed Central

    Shrestha, Gauri Shankar; Kaiti, Raju

    2013-01-01

    Purpose This study was undertaken to find correlations between visual functions and visual disabilities in patients with diabetic retinopathy. Method A cross-sectional study was carried out among 38 visually impaired diabetic retinopathy subjects at the Low Vision Clinic of B.P. Koirala Lions Centre for Ophthalmic Studies, Kathmandu. The subjects underwent assessment of distance and near visual acuity, objective and subjective refraction, contrast sensitivity, color vision, and central and peripheral visual fields. The visual disabilities of each subject in their daily lives were evaluated using a standard questionnaire. Multiple regression analysis between visual functions and visual disabilities index was assessed. Result The majority of subjects (42.1%) were of the age group 60–70 years. Best corrected visual acuity was found to be 0.73 ± 0.2 in the better eye and 0.93 ± 0.27 in the worse eye, which was significantly different at p = 0.002. Visual disability scores were significantly higher for legibility of letters (1.2 ± 0.3) and sentences (1.4 ± 0.4), and least for clothing (0.7 ± 0.3). Visual disability index for legibility of letters and sentences was significantly correlated with near visual acuity and peripheral visual field. Contrast sensitivity was also significantly correlated with the visual disability index, and total scores. Conclusion Impairment of near visual acuity, contrast sensitivity, and peripheral visual field correlated significantly with different types of visual disability. Hence, these clinical tests should be an integral part of the visual assessment of diabetic eyes. PMID:24646899

  6. Visual functions and disability in diabetic retinopathy patients.

    PubMed

    Shrestha, Gauri Shankar; Kaiti, Raju

    2014-01-01

    This study was undertaken to find correlations between visual functions and visual disabilities in patients with diabetic retinopathy. A cross-sectional study was carried out among 38 visually impaired diabetic retinopathy subjects at the Low Vision Clinic of B.P. Koirala Lions Centre for Ophthalmic Studies, Kathmandu. The subjects underwent assessment of distance and near visual acuity, objective and subjective refraction, contrast sensitivity, color vision, and central and peripheral visual fields. The visual disabilities of each subject in their daily lives were evaluated using a standard questionnaire. Multiple regression analysis between visual functions and visual disabilities index was assessed. The majority of subjects (42.1%) were of the age group 60-70 years. Best corrected visual acuity was found to be 0.73±0.2 in the better eye and 0.93±0.27 in the worse eye, which was significantly different at p=0.002. Visual disability scores were significantly higher for legibility of letters (1.2±0.3) and sentences (1.4±0.4), and least for clothing (0.7±0.3). Visual disability index for legibility of letters and sentences was significantly correlated with near visual acuity and peripheral visual field. Contrast sensitivity was also significantly correlated with the visual disability index, and total scores. Impairment of near visual acuity, contrast sensitivity, and peripheral visual field correlated significantly with different types of visual disability. Hence, these clinical tests should be an integral part of the visual assessment of diabetic eyes. Copyright © 2013 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  7. [Static and dynamic contrast sensitivity of myopic eyes before and after laser in situ keratomileusis].

    PubMed

    Liu, Xiao-wei; Pang, Guo-xiang; Liu, Xi-pu; Jiang, Ru-xin; Jin, Yu-mei; Sun, Yu-min; Wang, Zhong-hai

    2003-10-01

    To evaluate the static and dynamic contrast sensitivity changes in myopic patients before and after laser in situ keratomileusis (LASIK). Seventy-three eyes in 37 patients with myopia (with or without astigmatism) who received LASIK were tested for static and dynamic contrast sensitivities using the METRO VISION MON ELEC I system at 0.7, 1.4, 2.7, 5.5, 11, and 22 cpd and cps prior to LASIK, and at one-, three-, and six-month intervals after LASIK. All eyes gained naked visual acuity of more than 0.5 after LASIK. The contrast sensitivity was depressed at all frequencies 1 month after LASIK, as compared to one week prior to LASIK. The depression at 2.7, 5.5, 11 (P < 0.01) and 22 cpd (P < 0.05) was statistically significant for static contrast sensitivity, and also at 5.5 (P < 0.01) and 11 cps (P < 0.05) for dynamic contrast sensitivity. Myopic eyes between 6.25 D and 14.0 D, and astigmatic eyes 2 DC and more, suffered more static and dynamic contrast sensitivity depression than the myopic eyes between 1.25 D and 6.00 D and astigmatic eyes less than 2 DC. Contrast sensitivities were improved and exceeded preoperative levels 3 months after LASIK, and improved even more 6 months after LASIK. All sequences were statistically significant for static contrast sensitivity (P < 0.01), while only 2.7, 5.5, and 11 cps were statistically significant for dynamic contrast sensitivity (P < 0.01). The astigmatic eyes 2 DC and more showed less improvement, even below the preoperative level at 1.4 cps of dynamic contrast sensitivity. While temporary depression of contrast sensitivity for myopic eyes after LASIK was seen, contrast sensitivity soon returned to exceed preoperative levels at 3 months after LASIK, while improving even more 6 months after LASIK.

  8. VISUAL FUNCTION CHANGES AFTER SUBCHRONIC TOLUENE INHALATION IN LONG-EVANS RATS.

    EPA Science Inventory

    Chronic exposure to volatile organic compounds, including toluene, has been associated with visual deficits such as reduced visual contrast sensitivity or impaired color discrimination in studies of occupational or residential exposure. These reports remain controversial, howeve...

  9. Glare disability and driving safety.

    PubMed

    Babizhayev, M A

    2003-01-01

    Increasing investigation of the visual elements of safe driving environments may be of great benefit to society. Visual disability appears to be only one of many visual factors related to traffic accidents. The purpose of this article was to examine the type of visual impairment mediated by the increased glare sensitivity in adult drivers using the original halometer glare test. In this article, the visual sensory, cognitive and motor functions relevant to driving, their measurement, the epidemiology and prevention of age-associated functional impairments and the relationship of functional impairments to both self-reported driving and the imposition of legal restrictions are reviewed. The problem of night and tunnel driving is the most urgent in relation to the effects of glare from vehicle headlights on motion perception of drivers. The reduced mesopic vision and increased sensitivity to glare are accompanied by an increased risk of nighttime accidents. Elderly drivers and patients with beginning cataract cannot sufficiently fulfill the criteria for night driving ability because of contrast and glare sensitivity. It is indispensable for the parameters mentioned to be carefully measured and for drivers to be informed that night driving ability may be impaired, even if visual acuity is sufficient. It would be advisable for traffic safety if simple tests for contrast and glare sensitivity were implemented for vehicles and/or were regularly added to the requirements for a driver's licence, at least for older drivers. The age, functional status and test result limits should be defined to avoid a risk factor in traffic. Copyright 2003 S. Karger AG, Basel

  10. Toluene Inhalation Exposure for 13 Weeks Causes Persistent Changes in Electroretinograms of Long-Evans Rats

    EPA Science Inventory

    Studies of humans chronically exposed to volatile organic solvents have reported impaired visual functions, including low contrast sensitivity and reduced color discrimination. These reports, however, lacked confirmation from controlled laboratory experiments. To addre...

  11. Spatial Frequency Selectivity Is Impaired in Dopamine D2 Receptor Knockout Mice

    PubMed Central

    Souza, Bruno Oliveira Ferreira; Abou Rjeili, Mira; Quintana, Clémentine; Beaulieu, Jean M.; Casanova, Christian

    2018-01-01

    Dopamine is a neurotransmitter implicated in several brain functions, including vision. In the present study, we investigated the impacts of the lack of D2 dopamine receptors on the structure and function of the primary visual cortex (V1) of D2-KO mice using optical imaging of intrinsic signals. Retinotopic maps were generated in order to measure anatomo-functional parameters such as V1 shape, cortical magnification factor, scatter, and ocular dominance. Contrast sensitivity and spatial frequency selectivity (SF) functions were computed from responses to drifting gratings. When compared to control mice, none of the parameters of the retinotopic maps were affected by D2 receptor loss of function. While the contrast sensitivity function of D2-KO mice did not differ from their wild-type counterparts, SF selectivity function was significantly affected as the optimal SF and the high cut-off frequency (p < 0.01) were higher in D2-KO than in WT mice. These findings show that the lack of function of D2 dopamine receptors had no influence on cortical structure whereas it had a significant impact on the spatial frequency selectivity and high cut-off. Taken together, our results suggest that D2 receptors play a specific role on the processing of spatial features in early visual cortex while they do not seem to participate in its development. PMID:29379422

  12. Visual function after strontium-90 plaque irradiation in patients with age-related subfoveal choroidal neovascularization.

    PubMed

    Jaakkola, A; Heikkonen, J; Tarkkanen, A; Immonen, I

    1999-02-01

    To report 2-year visual and angiographic results in eyes treated with strontium plaque irradiation for subfoveal choroidal neovascular membranes (CNVM) in age-related macular degeneration. Twenty eyes with recent subfoveal CNVM were treated with local irradiation. The impact of the treatment on visual function was evaluated by visual acuity, contrast sensitivity and reading speed testing. At 12 months visual acuity had improved or remained the same in 9/ 20 eyes (45%). At 24 months visual acuity was stable in 5/18 eyes (28%). Eyes with signs of CNVM regression (13/18, 72%) lost a mean of 3.3 lines, but eyes with recurrent CNVM lost a mean of 5.1 lines of vision. The mean contrast sensitivity was better in the irradiated eyes than in the fellow eyes with late age-related macular degeneration at 24 months. Six of 17 irradiated eyes (35%) could read at least some words at 24 months. Visual function decreases in patients treated with strontium irradiation, but less in eyes showing regression of the CNVM than in eyes with further growth of the CNVM.

  13. Interactive MR image guidance for neurosurgical and minimally invasive procedures

    NASA Astrophysics Data System (ADS)

    Wong, Terence Z.; Schwartz, Richard B.; Pergolizzi, Richard S., Jr.; Black, Peter M.; Kacher, Daniel F.; Morrison, Paul R.; Jolesz, Ferenc A.

    1999-05-01

    Advantages of MR imaging for guidance of minimally invasive procedures include exceptional soft tissue contrast, intrinsic multiplanar imaging capability, and absence of exposure to ionizing radiation. Specialized imaging sequences are available and under development which can further enhance diagnosis and therapy. Flow-sensitive imaging techniques can be used to identify vascular structures. Temperature-sensitive imaging is possible which can provide interactive feedback prior to, during, and following the delivery of thermal energy. Functional MR imaging and dynamic contrast-enhanced MRI sequences can provide additional information for guidance in neurosurgical applications. Functional MR allows mapping of eloquent areas in the brain, so that these areas may be avoided during therapy. Dynamic contrast enhancement techniques can be useful for distinguishing active tumor from tumor necrosis caused by previous radiation therapy. An open-configuration 0.5T MRI system (GE Signa SP) developed at Brigham and Women's Hospital in collaboration with General Electric Medical Systems is described. Interactive navigation systems have been integrated into the MRI system. The imaging system is sited in an operating room environment, and used for image guided neurosurgical procedures (biopsies and tumor excision), as well as minimally invasive thermal therapies. Examples of MR imaging guidance, navigational techniques, and clinical applications are presented.

  14. V1 mechanisms underlying chromatic contrast detection

    PubMed Central

    Hass, Charles A.

    2013-01-01

    To elucidate the cortical mechanisms of color vision, we recorded from individual primary visual cortex (V1) neurons in macaque monkeys performing a chromatic detection task. Roughly 30% of the neurons that we encountered were unresponsive at the monkeys' psychophysical detection threshold (PT). The other 70% were responsive at threshold but on average, were slightly less sensitive than the monkey. For these neurons, the relationship between neurometric threshold (NT) and PT was consistent across the four isoluminant color directions tested. A corollary of this result is that NTs were roughly four times lower for stimuli that modulated the long- and middle-wavelength sensitive cones out of phase. Nearly one-half of the neurons that responded to chromatic stimuli at the monkeys' detection threshold also responded to high-contrast luminance modulations, suggesting a role for neurons that are jointly tuned to color and luminance in chromatic detection. Analysis of neuronal contrast-response functions and signal-to-noise ratios yielded no evidence for a special set of “cardinal color directions,” for which V1 neurons are particularly sensitive. We conclude that at detection threshold—as shown previously with high-contrast stimuli—V1 neurons are tuned for a diverse set of color directions and do not segregate naturally into red–green and blue–yellow categories. PMID:23446689

  15. Enhanced music sensitivity in 9-month-old bilingual infants.

    PubMed

    Liu, Liquan; Kager, René

    2017-02-01

    This study explores the influence of bilingualism on the cognitive processing of language and music. Specifically, we investigate how infants learning a non-tone language perceive linguistic and musical pitch and how bilingualism affects cross-domain pitch perception. Dutch monolingual and bilingual infants of 8-9 months participated in the study. All infants had Dutch as one of the first languages. The other first languages, varying among bilingual families, were not tone or pitch accent languages. In two experiments, infants were tested on the discrimination of a lexical (N = 42) or a violin (N = 48) pitch contrast via a visual habituation paradigm. The two contrasts shared identical pitch contours but differed in timbre. Non-tone language learning infants did not discriminate the lexical contrast regardless of their ambient language environment. When perceiving the violin contrast, bilingual but not monolingual infants demonstrated robust discrimination. We attribute bilingual infants' heightened sensitivity in the musical domain to the enhanced acoustic sensitivity stemming from a bilingual environment. The distinct perceptual patterns between language and music and the influence of acoustic salience on perception suggest processing diversion and association in the first year of life. Results indicate that the perception of music may entail both shared neural network with language processing, and unique neural network that is distinct from other cognitive functions.

  16. Optimum viewing distance for target acquisition

    NASA Astrophysics Data System (ADS)

    Holst, Gerald C.

    2015-05-01

    Human visual system (HVS) "resolution" (a.k.a. visual acuity) varies with illumination level, target characteristics, and target contrast. For signage, computer displays, cell phones, and TVs a viewing distance and display size are selected. Then the number of display pixels is chosen such that each pixel subtends 1 min-1. Resolution of low contrast targets is quite different. It is best described by Barten's contrast sensitivity function. Target acquisition models predict maximum range when the display pixel subtends 3.3 min-1. The optimum viewing distance is nearly independent of magnification. Noise increases the optimum viewing distance.

  17. A strategy to measure electrophysiological changes with photoacoustic imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Sepela, Rebecka J.; Sherlock, Benjamin E.; Tian, Lin; Marcu, Laura; Sack, Jon

    2017-03-01

    Photoacoustic imaging is an emerging technology capable of both functional and structural biological imaging. Absorption and scattering in tissue limit the penetration depth of conventional microscopy techniques to <1mm. Photoacoustic imaging however, can offer high-resolution and contrast at depths of several centimeters. Though functional imaging of endogenous contrast agents, such as hemoglobin, is widely implemented, currently photoacoustic imaging is unable to functionally report electrophysiological changes within cells. We aim to develop photoacoustic contrast agents to fulfill this need. Cells throughout the brain and body create electrical signals using ion channel proteins. These proteins undergo structural changes to regulate the flux of salt ions into the cell. We have recently developed ion channel activity tracers that dissociate from ion channels after the protein changes structure. By conjugating the tracer to dyes that are sensitive to changes in their chemical environment, we can detect tracer dissociation and therefore ion channel activity. We are exploring whether a similar mechanism can create photoacoustic signal intensity changes. To test if the environmental sensitivity of the dye is photoacoustically distinguishable, we imaged the dye in different solvent backgrounds. We report that manipulation of the chemical environment of the contrast dye results in robust changes in photoacoustic properties. We are working to capture photoacoustic signal changes that occur when ion channel proteins activate using live cell imaging. This technology could permit photoacoustic imaging of electrophysiological dynamics in deep tissue, such as the brain. Further optimization of this technology could lead to concurrent imaging of neural activity and hemodynamic responses, a crucial step towards understanding neurovascular coupling in the brain.

  18. Developmental Thyroid Hormone Insufficiency Impairs Visual Contrast Sensitivity in Adult Male Offspring.

    EPA Science Inventory

    Severe thyroid hormone (TH) insufficiency during early development results in alterations in brain structure and function. Many environmental agents produce subtle alterations in TH status, but the dose-response relationships for such effects are unclear. We have previously demon...

  19. Ultrasound-based quantification of vitreous floaters correlates with contrast sensitivity and quality of life.

    PubMed

    Mamou, Jonathan; Wa, Christianne A; Yee, Kenneth M P; Silverman, Ronald H; Ketterling, Jeffrey A; Sadun, Alfredo A; Sebag, J

    2015-01-22

    Clinical evaluation of floaters lacks quantitative assessment of vitreous structure. This study used quantitative ultrasound (QUS) to measure vitreous opacities. Since floaters reduce contrast sensitivity (CS) and quality of life (Visual Function Questionnaire [VFQ]), it is hypothesized that QUS will correlate with CS and VFQ in patients with floaters. Twenty-two eyes (22 subjects; age = 57 ± 19 years) with floaters were evaluated with Freiburg acuity contrast testing (FrACT; %Weber) and VFQ. Ultrasonography used a customized probe (15-MHz center frequency, 20-mm focal length, 7-mm aperture) with longitudinal and transverse scans taken in primary gaze and a horizontal longitudinal scan through premacular vitreous in temporal gaze. Each scan set had 100 frames of log-compressed envelope data. Within each frame, two regions of interest (ROIs) were analyzed (whole-central and posterior vitreous) to yield three parameters (energy, E; mean amplitude, M; and percentage of vitreous filled by echodensities, P50) averaged over the entire 100-frame dataset. Statistical analyses evaluated E, M, and P50 correlations with CS and VFQ. Contrast sensitivity ranged from 1.19%W (normal) to 5.59%W. All QUS parameters in two scan positions within the whole-central ROI correlated with CS (R > 0.67, P < 0.001). P50 in the nasal longitudinal position had R = 0.867 (P < 0.001). Correlations with VFQ ranged from R = 0.52 (P < 0.013) to R = 0.65 (P < 0.001). Quantitative ultrasound provides quantitative measures of vitreous echodensity that correlate with CS and VFQ, providing objective assessment of vitreous structure underlying the functional disturbances induced by floaters, useful to quantify vitreous disease severity and the response to therapy. Copyright 2015 The Association for Research in Vision and Ophthalmology, Inc.

  20. Ultrasound-Based Quantification of Vitreous Floaters Correlates with Contrast Sensitivity and Quality of Life

    PubMed Central

    Mamou, Jonathan; Wa, Christianne A.; Yee, Kenneth M. P.; Silverman, Ronald H.; Ketterling, Jeffrey A.; Sadun, Alfredo A.; Sebag, J.

    2015-01-01

    Purpose. Clinical evaluation of floaters lacks quantitative assessment of vitreous structure. This study used quantitative ultrasound (QUS) to measure vitreous opacities. Since floaters reduce contrast sensitivity (CS) and quality of life (Visual Function Questionnaire [VFQ]), it is hypothesized that QUS will correlate with CS and VFQ in patients with floaters. Methods. Twenty-two eyes (22 subjects; age = 57 ± 19 years) with floaters were evaluated with Freiburg acuity contrast testing (FrACT; %Weber) and VFQ. Ultrasonography used a customized probe (15-MHz center frequency, 20-mm focal length, 7-mm aperture) with longitudinal and transverse scans taken in primary gaze and a horizontal longitudinal scan through premacular vitreous in temporal gaze. Each scan set had 100 frames of log-compressed envelope data. Within each frame, two regions of interest (ROIs) were analyzed (whole-central and posterior vitreous) to yield three parameters (energy, E; mean amplitude, M; and percentage of vitreous filled by echodensities, P50) averaged over the entire 100-frame dataset. Statistical analyses evaluated E, M, and P50 correlations with CS and VFQ. Results. Contrast sensitivity ranged from 1.19%W (normal) to 5.59%W. All QUS parameters in two scan positions within the whole-central ROI correlated with CS (R > 0.67, P < 0.001). P50 in the nasal longitudinal position had R = 0.867 (P < 0.001). Correlations with VFQ ranged from R = 0.52 (P < 0.013) to R = 0.65 (P < 0.001). Conclusions. Quantitative ultrasound provides quantitative measures of vitreous echodensity that correlate with CS and VFQ, providing objective assessment of vitreous structure underlying the functional disturbances induced by floaters, useful to quantify vitreous disease severity and the response to therapy. PMID:25613948

  1. Vision Function in HIV-infected Individuals without Retinitis; Report of the Studies of Ocular Complications of AIDS Research Group

    PubMed Central

    Freeman, William R.; Van Natta, Mark L.; Jabs, Douglas; Sample, Pamela A.; Sadun, Alfredo A.; Thorne, Jennifer; Shah, Kayur H.; Holland, Gary N.

    2008-01-01

    Purpose To evaluate the prevalence and risk factors for vision loss in patients with clinical or immunologic AIDS without infectious retinitis. Design A prospective multicentered cohort study of patients with AIDS. Methods 1,351 patients (2,671 eyes) at 19 clinical trials centers diagnosed with AIDS but without major ocular complications of HIV. Standardized measurements of visual acuity, automated perimetry, and contrast sensitivity were analyzed and correlated with measurements of patients’ health and medical data relating to HIV infection. We evaluated correlations between vision function testing and HIV-related risk factors and medical testing. Results There were significant (p<0.05) associations between measures of decreasing vision function and indices of increasing disease severity including Karnofsky score and hemoglobin. A significant relationship was seen between low contrast sensitivity and decreasing levels of CD4+ T-cell count. Three percent of eyes had a visual acuity worse than 20/40 Snellen equivalents, which was significantly associated with a history of opportunistic infections and low Karnofsky score. When compared to external groups with normal vision, 39% of eyes had abnormal mean deviation on automated perimetry, 33% had abnormal pattern standard deviation, and 12% of eyes had low contrast sensitivity. Conclusions This study confirms that visual dysfunction is common in patients with AIDS but without retinitis. The most prevalent visual dysfunction is loss of visual field; nearly 40% of patients have some abnormal visual field. There is an association between general disease severity and less access to care and vision loss. The pathophysiology of this vision loss is unknown but is consistent with retinovascular disease or optic nerve disease. PMID:18191094

  2. Retooling Laser Speckle Contrast Analysis Algorithm to Enhance Non-Invasive High Resolution Laser Speckle Functional Imaging of Cutaneous Microcirculation

    NASA Astrophysics Data System (ADS)

    Gnyawali, Surya C.; Blum, Kevin; Pal, Durba; Ghatak, Subhadip; Khanna, Savita; Roy, Sashwati; Sen, Chandan K.

    2017-01-01

    Cutaneous microvasculopathy complicates wound healing. Functional assessment of gated individual dermal microvessels is therefore of outstanding interest. Functional performance of laser speckle contrast imaging (LSCI) systems is compromised by motion artefacts. To address such weakness, post-processing of stacked images is reported. We report the first post-processing of binary raw data from a high-resolution LSCI camera. Sharp images of low-flowing microvessels were enabled by introducing inverse variance in conjunction with speckle contrast in Matlab-based program code. Extended moving window averaging enhanced signal-to-noise ratio. Functional quantitative study of blood flow kinetics was performed on single gated microvessels using a free hand tool. Based on detection of flow in low-flow microvessels, a new sharp contrast image was derived. Thus, this work presents the first distinct image with quantitative microperfusion data from gated human foot microvasculature. This versatile platform is applicable to study a wide range of tissue systems including fine vascular network in murine brain without craniotomy as well as that in the murine dorsal skin. Importantly, the algorithm reported herein is hardware agnostic and is capable of post-processing binary raw data from any camera source to improve the sensitivity of functional flow data above and beyond standard limits of the optical system.

  3. Retooling Laser Speckle Contrast Analysis Algorithm to Enhance Non-Invasive High Resolution Laser Speckle Functional Imaging of Cutaneous Microcirculation

    PubMed Central

    Gnyawali, Surya C.; Blum, Kevin; Pal, Durba; Ghatak, Subhadip; Khanna, Savita; Roy, Sashwati; Sen, Chandan K.

    2017-01-01

    Cutaneous microvasculopathy complicates wound healing. Functional assessment of gated individual dermal microvessels is therefore of outstanding interest. Functional performance of laser speckle contrast imaging (LSCI) systems is compromised by motion artefacts. To address such weakness, post-processing of stacked images is reported. We report the first post-processing of binary raw data from a high-resolution LSCI camera. Sharp images of low-flowing microvessels were enabled by introducing inverse variance in conjunction with speckle contrast in Matlab-based program code. Extended moving window averaging enhanced signal-to-noise ratio. Functional quantitative study of blood flow kinetics was performed on single gated microvessels using a free hand tool. Based on detection of flow in low-flow microvessels, a new sharp contrast image was derived. Thus, this work presents the first distinct image with quantitative microperfusion data from gated human foot microvasculature. This versatile platform is applicable to study a wide range of tissue systems including fine vascular network in murine brain without craniotomy as well as that in the murine dorsal skin. Importantly, the algorithm reported herein is hardware agnostic and is capable of post-processing binary raw data from any camera source to improve the sensitivity of functional flow data above and beyond standard limits of the optical system. PMID:28106129

  4. Google Glass Glare: disability glare produced by a head-mounted visual display.

    PubMed

    Longley, Chris; Whitaker, David

    2016-03-01

    Head mounted displays are a type of wearable technology - a market that is projected to expand rapidly over the coming years. Probably the most well known example is the device Google Glass (or 'Glass'). Here we investigate the extent to which the device display can interfere with normal visual function by producing monocular disability glare. Contrast sensitivity was measured in two normally sighted participants, 32 and 52 years of age. Data were recorded for the right eye, the left eye and then again in a binocular condition. Measurements were taken both with and without the Glass in place, across a range of stimulus luminance levels using a two-alternative forced-choice methodology. The device produced a significant reduction in contrast sensitivity in the right eye (>0.5 log units). The level of disability glare increased as stimulus luminance was reduced in a manner consistent with intraocular light scatter, resulting in a veiling retinal illuminance. Sensitivity in the left eye was unaffected. A significant reduction in binocular contrast sensitivity occurred at lower luminance levels due to a loss of binocular summation, although binocular sensitivity was not found to fall below the sensitivity of the better monocular level (binocular inhibition). Head mounted displays such as Google Glass have the potential to cause significant disability glare in the eye exposed to the visual display, particularly under conditions of low luminance. They can also cause a more modest binocular reduction in sensitivity by eliminating the benefits of binocular summation. © 2015 The Authors Ophthalmic & Physiological Optics © 2015 The College of Optometrists.

  5. Detecting effects of donepezil on visual selective attention using signal detection parameters in Alzheimer's disease.

    PubMed

    Foldi, Nancy S; White, Richard E C; Schaefer, Lynn A

    2005-05-01

    Attentional function is impaired in Alzheimer's disease (AD). Moreover, attention is mediated by acetylcholine. But, despite the widespread use of acetylcholinesterase inhibitors (AChE-I) to augment available acetylcholine in AD, measures of attentional function have not been used to assess the drug response. We hypothesized that as cholinergic augmentation impacts directly on the attentional system, higher-order measures of visual selective attention would be sensitive to effects of treatment using an AChE-I (donepezil hydrochloride). We also sought to determine whether these attentional measures were more sensitive to treatment than other measures of cognitive function. Seventeen patients with AD (8 untreated, 9 treated with donepezil) were contrasted on performance of a selective cancellation task. Two signal detection parameters were used as outcome measures: decision strategy (beta, beta) and discriminability (d-prime, d'). Standard screening and cognitive domain measures of vigilance, language, memory, and executive function were also contrasted. Treated patients judged stimuli more conservatively (p = 0.29) by correctly endorsing targets and rejecting false alarms. They also discriminated targets from distractors more easily (p = 0.58). The screening and neuropsychological measures failed to differentiate the groups. Higher-order attentional measures captured the effects of donepezil treatment in small groups of patients with AD. The results suggest that cholinergic availability may directly affect the attentional system, and that these selective attention measures are sensitive markers to detect treatment response. Copyright 2005 John Wiley & Sons, Ltd.

  6. Influence of local inhomogeneities induced in corneal ablation on the evolution of contrast sensitivity

    NASA Astrophysics Data System (ADS)

    Ortiz, Dolores; Saiz, Jose M.; González, Francisco

    2004-04-01

    The presence of local inhomogeneities in corneal tissue after refractive surgery has an influence on visual performance. Here we focus on the corneal ablation associated with Lasik surgery and its effect on the modulation transfer function (MTF) that we obtained by modifying a personalized Kooijman model. Inhomogeneities induced by the ablation occur in the form of Gaussian-distributed refractive-index variations of a given correlation length. We show how variation of refractive-index deviation and correlation length (size) of the inhomogeneities allows us to obtain pairs of values that are able to achieve a MTF evolution similar to that observed for contrast sensitivity in the same patients. An estimate of the characteristics of the local effects is obtained.

  7. Visual Acuity and Contrast Sensitivity Development in Children: Sweep Visually Evoked Potential and Psychophysics.

    PubMed

    Almoqbel, Fahad M; Irving, Elizabeth L; Leat, Susan J

    2017-08-01

    The purpose of this study was to investigate the development of visual acuity (VA) and contrast sensitivity in children as measured with objective (sweep visually evoked potential) and subjective, psychophysical techniques, including signal detection theory (SDT), which attempts to control for differences in criterion or behavior between adults and children. Furthermore, this study examines the possibility of applying SDT methods with children. Visual acuity and contrast thresholds were measured in 12 children 6 to 7 years old, 10 children 8 to 9 years old, 10 children 10 to 12 years old, and 16 adults. For sweep visually evoked potential measurements, spatial frequency was swept from 1 to 40 cpd to measure VA, and contrast of sine-wave gratings (1 or 8 cpd) was swept from 0.33 to 30% to measure contrast thresholds. For psychophysical measurements, VA and contrast thresholds (1 or 8 cpd) were measured using a temporal two-alternative forced-choice staircase procedure and also with a yes-no SDT procedure. Optotype (logMAR [log of the minimum angle of resolution]) VA was also measured. The results of the various procedures were in agreement showing that there are age-related changes in threshold values and logMAR VA after the age of 6 years and that these visual functions do not become adult-like until the age of 8 to 9 years at the earliest. It was also found that children can participate in SDT procedures and do show differences in criterion compared with adults in psychophysical testing. These findings confirm a slightly later development of VA and contrast sensitivity (8 years or older) and indicate the importance of using SDT or forced-choice procedures in any developmental study to attempt to overcome the effect of criterion in children.

  8. Repetition priming influences distinct brain systems: evidence from task-evoked data and resting-state correlations.

    PubMed

    Wig, Gagan S; Buckner, Randy L; Schacter, Daniel L

    2009-05-01

    Behavioral dissociations suggest that a single experience can separately influence multiple processing components. Here we used a repetition priming functional magnetic resonance imaging paradigm that directly contrasted the effects of stimulus and decision changes to identify the underlying brain systems. Direct repetition of stimulus features caused marked reductions in posterior regions of the inferior temporal lobe that were insensitive to whether the decision was held constant or changed between study and test. By contrast, prefrontal cortex showed repetition effects that were sensitive to the exact stimulus-to-decision mapping. Analysis of resting-state functional connectivity revealed that the dissociated repetition effects are embedded within distinct brain systems. Regions that were sensitive to changes in the stimulus correlated with perceptual cortices, whereas the decision changes attenuated activity in regions correlated with middle-temporal regions and a frontoparietal control system. These results thus explain the long-known dissociation between perceptual and conceptual components of priming by revealing how a single experience can separately influence distinct, concurrently active brain systems.

  9. Novel medical imaging technologies for disease diagnosis and treatment

    NASA Astrophysics Data System (ADS)

    Olego, Diego

    2009-03-01

    New clinical approaches for disease diagnosis, treatment and monitoring will rely on the ability of simultaneously obtaining anatomical, functional and biological information. Medical imaging technologies in combination with targeted contrast agents play a key role in delivering with ever increasing temporal and spatial resolution structural and functional information about conditions and pathologies in cardiology, oncology and neurology fields among others. This presentation will review the clinical motivations and physics challenges in on-going developments of new medical imaging techniques and the associated contrast agents. Examples to be discussed are: *The enrichment of computer tomography with spectral sensitivity for the diagnosis of vulnerable sclerotic plaque. *Time of flight positron emission tomography for improved resolution in metabolic characterization of pathologies. *Magnetic particle imaging -a novel imaging modality based on in-vivo measurement of the local concentration of iron oxide nano-particles - for blood perfusion measurement with better sensitivity, spatial resolution and 3D real time acquisition. *Focused ultrasound for therapy delivery.

  10. Wavefront-guided versus wavefront-optimized laser in situ keratomileusis: contralateral comparative study.

    PubMed

    Padmanabhan, Prema; Mrochen, Michael; Basuthkar, Subam; Viswanathan, Deepa; Joseph, Roy

    2008-03-01

    To compare the outcomes of wavefront-guided and wavefront-optimized treatment in fellow eyes of patients having laser in situ keratomileusis (LASIK) for myopia. Medical and Vision Research Foundation, Tamil Nadu, India. This prospective comparative study comprised 27 patients who had wavefront-guided LASIK in 1 eye and wavefront-optimized LASIK in the fellow eye. The Hansatome (Bausch & Lomb) was used to create a superior-hinged flap and the Allegretto laser (WaveLight Laser Technologie AG), for photoablation. The Allegretto wave analyzer was used to measure ocular wavefront aberrations and the Functional Acuity Contrast Test chart, to measure contrast sensitivity before and 1 month after LASIK. The refractive and visual outcomes and the changes in aberrations and contrast sensitivity were compared between the 2 treatment modalities. One month postoperatively, 92% of eyes in the wavefront-guided group and 85% in the wavefront-optimized group had uncorrected visual acuity of 20/20 or better; 93% and 89%, respectively, had a postoperative spherical equivalent refraction of +/-0.50 diopter. The differences between groups were not statistically significant. Wavefront-guided LASIK induced less change in 18 of 22 higher-order Zernike terms than wavefront-optimized LASIK, with the change in positive spherical aberration the only statistically significant one (P= .01). Contrast sensitivity improved at the low and middle spatial frequencies (not statistically significant) and worsened significantly at high spatial frequencies after wavefront-guided LASIK; there was a statistically significant worsening at all spatial frequencies after wavefront-optimized LASIK. Although both wavefront-guided and wavefront-optimized LASIK gave excellent refractive correction results, the former induced less higher-order aberrations and was associated with better contrast sensitivity.

  11. TH-EF-207A-04: A Dynamic Contrast Enhanced Cone Beam CT Technique for Evaluation of Renal Functions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Z; Shi, J; Yang, Y

    Purpose: To develop a simple but robust method for the early detection and evaluation of renal functions using dynamic contrast enhanced cone beam CT technique. Methods: Experiments were performed on an integrated imaging and radiation research platform developed by our lab. Animals (n=3) were anesthetized with 20uL Ketamine/Xylazine cocktail, and then received 200uL injection of iodinated contrast agent Iopamidol via tail vein. Cone beam CT was acquired following contrast injection once per minute and up to 25 minutes. The cone beam CT was reconstructed with a dimension of 300×300×800 voxels of 130×130×130um voxel resolution. The middle kidney slices in themore » transvers and coronal planes were selected for image analysis. A double exponential function was used to fit the contrast enhanced signal intensity versus the time after contrast injection. Both pixel-based and region of interest (ROI)-based curve fitting were performed. Four parameters obtained from the curve fitting, namely the amplitude and flow constant for both contrast wash in and wash out phases, were investigated for further analysis. Results: Robust curve fitting was demonstrated for both pixel based (with R{sup 2}>0.8 for >85% pixels within the kidney contour) and ROI based (R{sup 2}>0.9 for all regions) analysis. Three different functional regions: renal pelvis, medulla and cortex, were clearly differentiated in the functional parameter map in the pixel based analysis. ROI based analysis showed the half-life T1/2 for contrast wash in and wash out phases were 0.98±0.15 and 17.04±7.16, 0.63±0.07 and 17.88±4.51, and 1.48±0.40 and 10.79±3.88 minutes for the renal pelvis, medulla and cortex, respectively. Conclusion: A robust method based on dynamic contrast enhanced cone beam CT and double exponential curve fitting has been developed to analyze the renal functions for different functional regions. Future study will be performed to investigate the sensitivity of this technique in the detection of radiation induced kidney dysfunction.« less

  12. Contrast Sensitivity With a Subretinal Prosthesis and Implications for Efficient Delivery of Visual Information

    PubMed Central

    Goetz, Georges; Smith, Richard; Lei, Xin; Galambos, Ludwig; Kamins, Theodore; Mathieson, Keith; Sher, Alexander; Palanker, Daniel

    2015-01-01

    Purpose To evaluate the contrast sensitivity of a degenerate retina stimulated by a photovoltaic subretinal prosthesis, and assess the impact of low contrast sensitivity on transmission of visual information. Methods We measure ex vivo the full-field contrast sensitivity of healthy rat retina stimulated with white light, and the contrast sensitivity of degenerate rat retina stimulated with a subretinal prosthesis at frequencies exceeding flicker fusion (>20 Hz). Effects of eye movements on retinal ganglion cell (RGC) activity are simulated using a linear–nonlinear model of the retina. Results Retinal ganglion cells adapt to high frequency stimulation of constant intensity, and respond transiently to changes in illumination of the implant, exhibiting responses to ON-sets, OFF-sets, and both ON- and OFF-sets of light. The percentage of cells with an OFF response decreases with progression of the degeneration, indicating that OFF responses are likely mediated by photoreceptors. Prosthetic vision exhibits reduced contrast sensitivity and dynamic range, with 65% contrast changes required to elicit responses, as compared to the 3% (OFF) to 7% (ON) changes with visible light. The maximum number of action potentials elicited with prosthetic stimulation is at most half of its natural counterpart for the ON pathway. Our model predicts that for most visual scenes, contrast sensitivity of prosthetic vision is insufficient for triggering RGC activity by fixational eye movements. Conclusions Contrast sensitivity of prosthetic vision is 10 times lower than normal, and dynamic range is two times below natural. Low contrast sensitivity and lack of OFF responses hamper delivery of visual information via a subretinal prosthesis. PMID:26540657

  13. Design analysis of an MPI human functional brain scanner

    PubMed Central

    Mason, Erica E.; Cooley, Clarissa Z.; Cauley, Stephen F.; Griswold, Mark A.; Conolly, Steven M.; Wald, Lawrence L.

    2017-01-01

    MPI’s high sensitivity makes it a promising modality for imaging brain function. Functional contrast is proposed based on blood SPION concentration changes due to Cerebral Blood Volume (CBV) increases during activation, a mechanism utilized in fMRI studies. MPI offers the potential for a direct and more sensitive measure of SPION concentration, and thus CBV, than fMRI. As such, fMPI could surpass fMRI in sensitivity, enhancing the scientific and clinical value of functional imaging. As human-sized MPI systems have not been attempted, we assess the technical challenges of scaling MPI from rodent to human brain. We use a full-system MPI simulator to test arbitrary hardware designs and encoding practices, and we examine tradeoffs imposed by constraints that arise when scaling to human size as well as safety constraints (PNS and central nervous system stimulation) not considered in animal scanners, thereby estimating spatial resolutions and sensitivities achievable with current technology. Using a projection FFL MPI system, we examine coil hardware options and their implications for sensitivity and spatial resolution. We estimate that an fMPI brain scanner is feasible, although with reduced sensitivity (20×) and spatial resolution (5×) compared to existing rodent systems. Nonetheless, it retains sufficient sensitivity and spatial resolution to make it an attractive future instrument for studying the human brain; additional technical innovations can result in further improvements. PMID:28752130

  14. Real-time myocardial perfusion imaging for pharmacologic stress testing: added value to single photon emission computed tomography.

    PubMed

    Korosoglou, Grigorios; Dubart, Alain-Eric; DaSilva, K Gaspar C; Labadze, Nino; Hardt, Stefan; Hansen, Alexander; Bekeredjian, Raffi; Zugck, Christian; Zehelein, Joerg; Katus, Hugo A; Kuecherer, Helmut

    2006-01-01

    Little is known about the incremental value of real-time myocardial contrast echocardiography (MCE) as an adjunct to pharmacologic stress testing. This study was performed to evaluate the diagnostic value of MCE to detect abnormal myocardial perfusion by technetium Tc 99m sestamibi-single photon emission computed tomography (SPECT) and anatomically significant coronary artery disease (CAD) by angiography. Myocardial contrast echocardiography was performed at rest and during vasodilator stress in consecutive patients (N = 120) undergoing SPECT imaging for known or suspected CAD. Myocardial opacification, wall motion, and tracer uptake were visually analyzed in 12 myocardial segments by 2 pairs of blinded observers. Concordance between the 2 methods was assessed using the kappa statistic. Of 1356 segments, 1025 (76%) were interpretable by MCE, wall motion, and SPECT. Sensitivity of wall motion was 75%, specificity 83%, and accuracy 81% for detecting abnormal myocardial perfusion by SPECT (kappa = 0.53). Myocardial contrast echocardiography and wall motion together yielded significantly higher sensitivity (85% vs 74%, P < .05), specificity of 83%, and accuracy of 85% (kappa = 0.64) for the detection of abnormal myocardial perfusion. In 89 patients who underwent coronary angiography, MCE and wall motion together yielded higher sensitivity (83% vs 64%, P < .05) and accuracy (77% vs 68%, P < .05) but similar specificity (72%) compared with SPECT for the detection of high-grade, stenotic (> or = 75%) coronary lesions. Assessment of myocardial perfusion adds value to conventional stress echocardiography by increasing its sensitivity for the detection of functionally abnormal myocardial perfusion. Myocardial contrast echocardiography and wall motion together provide higher sensitivity and accuracy for detection of CAD compared with SPECT.

  15. Journal Club: Comparison of assessment of preoperative pulmonary vasculature in patients with non-small cell lung cancer by non-contrast- and 4D contrast-enhanced 3-T MR angiography and contrast-enhanced 64-MDCT.

    PubMed

    Ohno, Yoshiharu; Nishio, Mizuho; Koyama, Hisanobu; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Seki, Shinichiro; Sugimura, Kazuro

    2014-03-01

    The purpose of this article is to prospectively and directly compare the capabilities of non-contrast-enhanced MR angiography (MRA), 4D contrast-enhanced MRA, and contrast-enhanced MDCT for assessing pulmonary vasculature in patients with non-small cell lung cancer (NSCLC) before surgical treatment. A total of 77 consecutive patients (41 men and 36 women; mean age, 71 years) with pathologically proven and clinically assessed stage I NSCLC underwent thin-section contrast-enhanced MDCT, non-contrast-enhanced and contrast-enhanced MRA, and surgical treatment. The capability for anomaly assessment of the three methods was independently evaluated by two reviewers using a 5-point visual scoring system, and final assessment for each patient was made by consensus of the two readers. Interobserver agreement for pulmonary arterial and venous assessment was evaluated with the kappa statistic. Then, sensitivity, specificity, and accuracy for the detection of anomalies were directly compared among the three methods by use of the McNemar test. Interobserver agreement for pulmonary artery and vein assessment was substantial or almost perfect (κ=0.72-0.86). For pulmonary arterial and venous variation assessment, there were no significant differences in sensitivity, specificity, and accuracy among non-contrast-enhanced MRA (pulmonary arteries: sensitivity, 77.1%; specificity, 97.4%; accuracy, 87.7%; pulmonary veins: sensitivity, 50%; specificity, 98.5%; accuracy, 93.2%), 4D contrast-enhanced MRA (pulmonary arteries: sensitivity, 77.1%; specificity, 97.4%; accuracy, 87.7%; pulmonary veins: sensitivity, 62.5%; specificity, 100.0%; accuracy, 95.9%), and thin-section contrast-enhanced MDCT (pulmonary arteries: sensitivity, 91.4%; specificity, 89.5%; accuracy, 90.4%; pulmonary veins: sensitivity, 50%; specificity, 100.0%; accuracy, 95.9%) (p>0.05). Pulmonary vascular assessment of patients with NSCLC before surgical resection by non-contrast-enhanced MRA can be considered equivalent to that by 4D contrast-enhanced MRA and contrast-enhanced MDCT.

  16. The relationship between hue discrimination and contrast sensitivity deficits in patients with diabetes mellitus.

    PubMed

    Trick, G L; Burde, R M; Gordon, M O; Santiago, J V; Kilo, C

    1988-05-01

    In an attempt to elucidate more fully the pathophysiologic basis of early visual dysfunction in patients with diabetes mellitus, color vision (hue discrimination) and spatial resolution (contrast sensitivity) were tested in diabetic patients with little or no retinopathy (n = 57) and age-matched visual normals (n = 35). Some evidence of visual dysfunction was observed in 37.8% of the diabetics with no retinopathy and 60.0% of the diabetics with background retinopathy. Although significant hue discrimination and contrast sensitivity deficits were observed in both groups of diabetic patients, contrast sensitivity was abnormal more frequently than hue discrimination. However, only 5.4% of the diabetics with no retinopathy and 10.0% of the diabetics with background retinopathy exhibited both abnormal hue discrimination and abnormal contrast sensitivity. Contrary to previous reports, blue-yellow (B-Y) and red-green (R-G) hue discrimination deficits were observed with approximately equal frequency. In the diabetic group, contrast sensitivity was reduced at all spatial frequencies tested, but for individual diabetic patients, significant deficits were only evident for the mid-range spatial frequencies. Among diabetic patients, the hue discrimination deficits, but not the contrast sensitivity abnormalities, were correlated with the patients' hemoglobin A1 level. A negative correlation between contrast sensitivity at 6.0 cpd and the duration of diabetes also was observed.

  17. Evaluation of possible factors affecting contrast sensitivity function in patients with primary Sjögren's syndrome.

    PubMed

    Arikan, Sedat; Gokmen, Ferhat; Comez, Arzu Taskiran; Gencer, Baran; Kara, Selcuk; Akbal, Ayla

    2015-01-01

    The contrast sensitivity (CS) function in patients with primary Sjögren's syndrome (pSS) may be impaired either frequently as a result of dry eye diseases or rarely as a result of optic neuropathy. In this study, we aimed to evaluate the CS function in pSS patients as well as to assess corneal aberrations and thickness of the peripapillary retinal nerve fiber layer (pRNFL). Fourteen eyes of 14 pSS patients (pSS group) and 14 eyes of 14 healthy participants (control group) were subjected to assessment of CS at the spatial frequencies of 1.5, 3.0, 6.0, 12, and 18 cycles/degree (cpd) using a functional visual acuity contrast test (FACT); measurement of corneal high-order aberrations (HOAs) in terms of coma-like, spherical-like, and total HOAs using Scheimpflug corneal topography; and measurement of the thickness of both the macular ganglion cell-inner plexiform layer (mGCIPL) and pRNFL in all quadrants using optical coherence tomography. None of the participants were under treatment with artificial tears. The results of the CS test did not differ between the 2 groups at all spatial frequencies (p>0.05). In addition, there were no statistically significant differences between the 2 groups in terms of corneal HOAs (p>0.05) and thickness of mGCIPL (p>0.05). However, among all quadrants, only the inferior quadrant of pRNFL in pSS patients was statistically significantly thinner than that in the healthy participants (p=0.04). The CS function in pSS patients can be maintained with normal thickness of both pRNFL and mGCIPL and with lack of increased corneal HOAs, which may be present even in the absence of artificial tear usage.

  18. Establishing New Mappings between Familiar Phones: Neural and Behavioral Evidence for Early Automatic Processing of Nonnative Contrasts

    PubMed Central

    Barrios, Shannon L.; Namyst, Anna M.; Lau, Ellen F.; Feldman, Naomi H.; Idsardi, William J.

    2016-01-01

    To attain native-like competence, second language (L2) learners must establish mappings between familiar speech sounds and new phoneme categories. For example, Spanish learners of English must learn that [d] and [ð], which are allophones of the same phoneme in Spanish, can distinguish meaning in English (i.e., /deɪ/ “day” and /ðeɪ/ “they”). Because adult listeners are less sensitive to allophonic than phonemic contrasts in their native language (L1), novel target language contrasts between L1 allophones may pose special difficulty for L2 learners. We investigate whether advanced Spanish late-learners of English overcome native language mappings to establish new phonological relations between familiar phones. We report behavioral and magnetoencepholographic (MEG) evidence from two experiments that measured the sensitivity and pre-attentive processing of three listener groups (L1 English, L1 Spanish, and advanced Spanish late-learners of English) to differences between three nonword stimulus pairs ([idi]-[iði], [idi]-[iɾi], and [iði]-[iɾi]) which differ in phones that play a different functional role in Spanish and English. Spanish and English listeners demonstrated greater sensitivity (larger d' scores) for nonword pairs distinguished by phonemic than by allophonic contrasts, mirroring previous findings. Spanish late-learners demonstrated sensitivity (large d' scores and MMN responses) to all three contrasts, suggesting that these L2 learners may have established a novel [d]-[ð] contrast despite the phonological relatedness of these sounds in the L1. Our results suggest that phonological relatedness influences perceived similarity, as evidenced by the results of the native speaker groups, but may not cause persistent difficulty for advanced L2 learners. Instead, L2 learners are able to use cues that are present in their input to establish new mappings between familiar phones. PMID:27445949

  19. Long-term changes in retinal contrast sensitivity in chicks from frosted occluders and drugs: relations to myopia?

    PubMed

    Diether, S; Schaeffel, F

    1999-07-01

    Experiments in animal models have shown that the retinal analyzes the image to identify the position of the plane of focus and fine-tunes the growth of the underlying sclera. It is fundamental to the understanding of the development of refractive errors to know which image features are processed. Since the position of the image plane fluctuates continuously with accommodative status and viewing distance, a meaningful control of refractive development can only occur by an averaging procedure with a long time constant. As a candidate for a retinal signal for enhanced eye growth and myopia we propose the level of contrast adaptation which varies with the average amount of defocus. Using a behavioural paradigm, we have found in chickens (1) that contrast adaptation (CA, here referred to as an increase in contrast sensitivity) occurs at low spatial frequencies (0.2 cyc/deg) already after 1.5 h of wearing frosted goggles which cause deprivation myopia, (2) that CA also occurs with negative lenses (-7.4D) and positive lenses (+6.9D) after 1.5 h, at least if accommodation is paralyzed and, (3) that CA occurs at a retinal level or has, at least, a retinal component. Furthermore, we have studied the effects of atropine and reserpine, which both suppress myopia development, on CA. Quisqualate, which causes retinal degeneration but leaves emmetropization functional, was also tested. We found that both atropine and reserpine increase contrast sensitivity to a level where no further CA could be induced by frosted goggles. Quisqualate increased only the variability of refractive development and of contrast sensitivity. Taken together, CA occurring during extended periods of defocus is a possible candidate for a retinal error signal for myopia development. However, the situation is complicated by the fact that there must be a second image processing mode generating a powerful inhibitory growth signal if the image is in front of the retina, even with poor images (Diether, S., & Schaeffel, F. (1999).

  20. [Gadolinium-based contrast agents for magnetic resonance imaging].

    PubMed

    Carrasco Muñoz, S; Calles Blanco, C; Marcin, Javier; Fernández Álvarez, C; Lafuente Martínez, J

    2014-06-01

    Gadolinium-based contrast agents are increasingly being used in magnetic resonance imaging. These agents can improve the contrast in images and provide information about function and metabolism, increasing both sensitivity and specificity. We describe the gadolinium-based contrast agents that have been approved for clinical use, detailing their main characteristics based on their chemical structure, stability, and safety. In general terms, these compounds are safe. Nevertheless, adverse reactions, the possibility of nephrotoxicity from these compounds, and the possibility of developing nephrogenic systemic fibrosis will be covered in this article. Lastly, the article will discuss the current guidelines, recommendations, and contraindications for their clinical use, including the management of pregnant and breast-feeding patients. Copyright © 2014 SERAM. Published by Elsevier Espana. All rights reserved.

  1. Exposure to Organic Solvents Used in Dry Cleaning Reduces Low and High Level Visual Function

    PubMed Central

    Jiménez Barbosa, Ingrid Astrid

    2015-01-01

    Purpose To investigate whether exposure to occupational levels of organic solvents in the dry cleaning industry is associated with neurotoxic symptoms and visual deficits in the perception of basic visual features such as luminance contrast and colour, higher level processing of global motion and form (Experiment 1), and cognitive function as measured in a visual search task (Experiment 2). Methods The Q16 neurotoxic questionnaire, a commonly used measure of neurotoxicity (by the World Health Organization), was administered to assess the neurotoxic status of a group of 33 dry cleaners exposed to occupational levels of organic solvents (OS) and 35 age-matched non dry-cleaners who had never worked in the dry cleaning industry. In Experiment 1, to assess visual function, contrast sensitivity, colour/hue discrimination (Munsell Hue 100 test), global motion and form thresholds were assessed using computerised psychophysical tests. Sensitivity to global motion or form structure was quantified by varying the pattern coherence of global dot motion (GDM) and Glass pattern (oriented dot pairs) respectively (i.e., the percentage of dots/dot pairs that contribute to the perception of global structure). In Experiment 2, a letter visual-search task was used to measure reaction times (as a function of the number of elements: 4, 8, 16, 32, 64 and 100) in both parallel and serial search conditions. Results Dry cleaners exposed to organic solvents had significantly higher scores on the Q16 compared to non dry-cleaners indicating that dry cleaners experienced more neurotoxic symptoms on average. The contrast sensitivity function for dry cleaners was significantly lower at all spatial frequencies relative to non dry-cleaners, which is consistent with previous studies. Poorer colour discrimination performance was also noted in dry cleaners than non dry-cleaners, particularly along the blue/yellow axis. In a new finding, we report that global form and motion thresholds for dry cleaners were also significantly higher and almost double than that obtained from non dry-cleaners. However, reaction time performance on both parallel and serial visual search was not different between dry cleaners and non dry-cleaners. Conclusions Exposure to occupational levels of organic solvents is associated with neurotoxicity which is in turn associated with both low level deficits (such as the perception of contrast and discrimination of colour) and high level visual deficits such as the perception of global form and motion, but not visual search performance. The latter finding indicates that the deficits in visual function are unlikely to be due to changes in general cognitive performance. PMID:25933026

  2. The Medical Hazards of Flame-Suppressant Atmospheres

    DTIC Science & Technology

    1991-04-19

    the external and middle earcavities. Graph B shows inward distension of the may need to be interrupted or slowed to eardrum produced by higher...experiments were performed by mental function, muscular coordination, military scientists (see ACKNOW- night vision, visual contrast sensitivity, LEDGEMENTS) in...task of muscular posure to change any of the visual coordination was slightly function tests (Luria & Knight, degraded during the first 4 h of 1987). the

  3. Contrast-enhanced optical coherence tomography with picomolar sensitivity for functional in vivo imaging

    NASA Astrophysics Data System (ADS)

    Liba, Orly; Sorelle, Elliott D.; Sen, Debasish; de La Zerda, Adam

    2016-03-01

    Optical Coherence Tomography (OCT) enables real-time imaging of living tissues at cell-scale resolution over millimeters in three dimensions. Despite these advantages, functional biological studies with OCT have been limited by a lack of exogenous contrast agents that can be distinguished from tissue. Here we report an approach to functional OCT imaging that implements custom algorithms to spectrally identify unique contrast agents: large gold nanorods (LGNRs). LGNRs exhibit 110-fold greater spectral signal per particle than conventional GNRs, which enables detection of individual LGNRs in water and concentrations as low as 250 pM in the circulation of living mice. This translates to ~40 particles per imaging voxel in vivo. Unlike previous implementations of OCT spectral detection, the methods described herein adaptively compensate for depth and processing artifacts on a per sample basis. Collectively, these methods enable high-quality noninvasive contrast-enhanced imaging of OCT in living subjects, including detection of tumor microvasculature at twice the depth achievable with conventional OCT. Additionally, multiplexed detection of spectrally-distinct LGNRs was demonstrated to observe discrete patterns of lymphatic drainage and identify individual lymphangions and lymphatic valve functional states. These capabilities provide a powerful platform for molecular imaging and characterization of tissue noninvasively at cellular resolution, called MOZART.

  4. Enhancing the Educational Effectiveness of Zoos.

    ERIC Educational Resources Information Center

    Braverman, Marc T.; Yates, Mary Ellen

    This study addressed whether the educational impact of a zoo visit can be enhanced through the provision of appropriate instructional supports such as preparatory trainings or orientations. One important function of the educational process, in contrast to providing direct information or skill development, is to make the learner more sensitive to…

  5. ELECTRORETINOGRAMS ARE ALTERED BY SUBCHRONIC TOLUENE EXPOSURE TO LONG EVANS RATS: EXPERIMENTAL EVIDENCE SUPPORTING OBSERVATIONS FROM STUDIES OF EXPOSED HUMANS

    EPA Science Inventory

    Impaired visual functions, including low contrast sensitivity and reduced color discrimination, have been reported in studies of humans chronically exposed to several volatile organic solvents. These reports remain controversial, however, in part due to a lack of confirmation fro...

  6. Development and evaluation of a method of calibrating medical displays based on fixed adaptation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sund, Patrik, E-mail: patrik.sund@vgregion.se; Månsson, Lars Gunnar; Båth, Magnus

    2015-04-15

    Purpose: The purpose of this work was to develop and evaluate a new method for calibration of medical displays that includes the effect of fixed adaptation and by using equipment and luminance levels typical for a modern radiology department. Methods: Low contrast sinusoidal test patterns were derived at nine luminance levels from 2 to 600 cd/m{sup 2} and used in a two alternative forced choice observer study, where the adaptation level was fixed at the logarithmic average of 35 cd/m{sup 2}. The contrast sensitivity at each luminance level was derived by establishing a linear relationship between the ten pattern contrastmore » levels used at every luminance level and a detectability index (d′) calculated from the fraction of correct responses. A Gaussian function was fitted to the data and normalized to the adaptation level. The corresponding equation was used in a display calibration method that included the grayscale standard display function (GSDF) but compensated for fixed adaptation. In the evaluation study, the contrast of circular objects with a fixed pixel contrast was displayed using both calibration methods and was rated on a five-grade scale. Results were calculated using a visual grading characteristics method. Error estimations in both observer studies were derived using a bootstrap method. Results: The contrast sensitivities for the darkest and brightest patterns compared to the contrast sensitivity at the adaptation luminance were 37% and 56%, respectively. The obtained Gaussian fit corresponded well with similar studies. The evaluation study showed a higher degree of equally distributed contrast throughout the luminance range with the calibration method compensated for fixed adaptation than for the GSDF. The two lowest scores for the GSDF were obtained for the darkest and brightest patterns. These scores were significantly lower than the lowest score obtained for the compensated GSDF. For the GSDF, the scores for all luminance levels were statistically separated from the average value; three were lower and two were higher. For the compensated GSDF, three of the scores could not be separated from the average value. Conclusions: An observer study using clinically relevant displays and luminance settings has demonstrated that the calibration of displays according to the GSDF causes the perceived contrast to be unevenly distributed when using displays with a high luminance range. As the luminance range increases, the perceived contrast in the dark and bright regions will be significantly lower than the perceived contrast in the middle of the luminance range. A new calibration method that includes the effect of fixed adaptation was developed and evaluated in an observer study and was found to distribute the contrast of the display more evenly throughout the grayscale than the GSDF.« less

  7. Temporal profile of functional visual rehabilitative outcomes modulated by transcranial direct current stimulation.

    PubMed

    Plow, Ela B; Obretenova, Souzana N; Jackson, Mary Lou; Merabet, Lotfi B

    2012-07-01

    We have previously reported that transcranial direct current stimulation (tDCS) delivered to the occipital cortex enhances visual functional recovery when combined with three months of computer-based rehabilitative training in patients with hemianopia. The principal objective of this study was to evaluate the temporal sequence of effects of tDCS on visual recovery as they appear over the course of training and across different indicators of visual function. Primary objective outcome measures were 1) shifts in visual field border and 2) stimulus detection accuracy within the affected hemifield. These were compared between patients randomized to either vision restoration therapy (VRT) combined with active tDCS or VRT paired with sham tDCS. Training comprised two half-hour sessions, three times a week for three months. Primary outcome measures were collected at baseline (pretest), monthly interim intervals, and at posttest (three months). As secondary outcome measures, contrast sensitivity and reading performance were collected at pretest and posttest time points only. Active tDCS combined with VRT accelerated the recovery of stimulus detection as between-group differences appeared within the first month of training. In contrast, a shift in the visual field border was only evident at posttest (after three months of training). tDCS did not affect contrast sensitivity or reading performance. These results suggest that tDCS may differentially affect the magnitude and sequence of visual recovery in a manner that is task specific to the type of visual rehabilitative training strategy employed. © 2012 International Neuromodulation Society.

  8. Executive functioning and substance use in adolescence: Neurobiological and behavioral perspectives.

    PubMed

    Kim-Spoon, Jungmeen; Kahn, Rachel E; Lauharatanahirun, Nina; Deater-Deckard, Kirby; Bickel, Warren K; Chiu, Pearl H; King-Casas, Brooks

    2017-06-01

    The current review is guided by the theoretical perspective that emphasizes the regulating role of executive functioning (Carver et al., 2009) and presents studies that elucidate the ways that executive functioning (inhibition and working memory) explain individual differences in adolescent substance use independently or by regulating the reactive system (reward and punishment sensitivity). Behavioral studies indicate that main effects of executive functioning on adolescent substance use are often nonsignificant or weak in effect sizes. In contrast, emerging evidence suggests consistent and stronger regulating effects of executive functioning over reward and punishment sensitivity. Functional neuroimaging studies reveal significant associations between executive functioning task-related hemodynamic responses and substance use with strong effect sizes. There is also direct evidence from studies testing statistical interactions of the regulating effects of EF-related brain activation, and indirect evidence in studies examining functional connectivity, temporal discounting, and reinforced control. We note key future directions and ways to address limitations in existing work. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. PHOTOMETRIC TRENDS IN THE VISIBLE SOLAR CONTINUUM AND THEIR SENSITIVITY TO THE CENTER-TO-LIMB PROFILE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peck, C. L.; Rast, M. P.

    2015-08-01

    Solar irradiance variations over solar rotational timescales are largely determined by the passage of magnetic structures across the visible solar disk. Variations on solar cycle timescales are thought to be similarly due to changes in surface magnetism with activity. Understanding the contribution of magnetic structures to total solar irradiance and solar spectral irradiance requires assessing their contributions as a function of disk position. Since only relative photometry is possible from the ground, the contrasts of image pixels are measured with respect to a center-to-limb intensity profile. Using nine years of full-disk red and blue continuum images from the Precision Solarmore » Photometric Telescope at the Mauna Loa Solar Observatory, we examine the sensitivity of continuum contrast measurements to the center-to-limb profile definition. Profiles which differ only by the amount of magnetic activity allowed in the pixels used to determine them yield oppositely signed solar cycle length continuum contrast trends, either agreeing with previous results and showing negative correlation with solar cycle or disagreeing and showing positive correlation with solar cycle. Changes in the center-to-limb profile shape over the solar cycle are responsible for the contradictory contrast results, and we demonstrate that the lowest contrast structures, internetwork and network, are most sensitive to these. Thus the strengths of the full-disk, internetwork, and network photometric trends depend critically on the magnetic flux density used in the quiet-Sun definition. We conclude that the contributions of low contrast magnetic structures to variations in the solar continuum output, particularly to long-term variations, are difficult, if not impossible, to determine without the use of radiometric imaging.« less

  10. Rapid pupil-based assessment of glaucomatous damage.

    PubMed

    Chen, Yanjun; Wyatt, Harry J; Swanson, William H; Dul, Mitchell W

    2008-06-01

    To investigate the ability of a technique employing pupillometry and functionally-shaped stimuli to assess loss of visual function due to glaucomatous optic neuropathy. Pairs of large stimuli, mirror images about the horizontal meridian, were displayed alternately in the upper and lower visual field. Pupil diameter was recorded and analyzed in terms of the "contrast balance" (relative sensitivity to the upper and lower stimuli), and the pupil constriction amplitude to upper and lower stimuli separately. A group of 40 patients with glaucoma was tested twice in a first session, and twice more in a second session, 1 to 3 weeks later. A group of 40 normal subjects was tested with the same protocol. Results for the normal subjects indicated functional symmetry in upper/lower retina, on average. Contrast balance results for the patients with glaucoma differed from normal: half the normal subjects had contrast balance within 0.06 log unit of equality and 80% had contrast balance within 0.1 log unit. Half the patients had contrast balances more than 0.1 log unit from equality. Patient contrast balances were moderately correlated with predictions from perimetric data (r = 0.37, p < 0.00001). Contrast balances correctly classified visual field damage in 28 patients (70%), and response amplitudes correctly classified 24 patients (60%). When contrast balance and response amplitude were combined, receiver operating characteristic area for discriminating glaucoma from normal was 0.83. Pupillary evaluation of retinal asymmetry provides a rapid method for detecting and classifying visual field defects. In this patient population, classification agreed with perimetry in 70% of eyes.

  11. Rapid Pupil-Based Assessment of Glaucomatous Damage

    PubMed Central

    Chen, Yanjun; Wyatt, Harry J.; Swanson, William H.; Dul, Mitchell W.

    2010-01-01

    Purpose To investigate the ability of a technique employing pupillometry and functionally-shaped stimuli to assess loss of visual function due to glaucomatous optic neuropathy. Methods Pairs of large stimuli, mirror images about the horizontal meridian, were displayed alternately in the upper and lower visual field. Pupil diameter was recorded and analyzed in terms of the “contrast balance” (relative sensitivity to the upper and lower stimuli), and the pupil constriction amplitude to upper and lower stimuli separately. A group of 40 patients with glaucoma was tested twice in a first session, and twice more in a second session, 1 to 3 weeks later. A group of 40 normal subjects was tested with the same protocol. Results Results for the normal subjects indicated functional symmetry in upper/lower retina, on average. Contrast balance results for the patients with glaucoma differed from normal: half the normal subjects had contrast balance within 0.06 log unit of equality and 80% had contrast balance within 0.1 log unit. Half the patients had contrast balances more than 0.1 log unit from equality. Patient contrast balances were moderately correlated with predictions from perimetric data (r = 0.37, p < 0.00001). Contrast balances correctly classified visual field damage in 28 patients (70%), and response amplitudes correctly classified 24 patients (60%). When contrast balance and response amplitude were combined, receiver operating characteristic area for discriminating glaucoma from normal was 0.83. Conclusions Pupillary evaluation of retinal asymmetry provides a rapid method for detecting and classifying visual field defects. In this patient population, classification agreed with perimetry in 70% of eyes. PMID:18521026

  12. Sensitivity to gaze-contingent contrast increments in naturalistic movies: An exploratory report and model comparison

    PubMed Central

    Wallis, Thomas S. A.; Dorr, Michael; Bex, Peter J.

    2015-01-01

    Sensitivity to luminance contrast is a prerequisite for all but the simplest visual systems. To examine contrast increment detection performance in a way that approximates the natural environmental input of the human visual system, we presented contrast increments gaze-contingently within naturalistic video freely viewed by observers. A band-limited contrast increment was applied to a local region of the video relative to the observer's current gaze point, and the observer made a forced-choice response to the location of the target (≈25,000 trials across five observers). We present exploratory analyses showing that performance improved as a function of the magnitude of the increment and depended on the direction of eye movements relative to the target location, the timing of eye movements relative to target presentation, and the spatiotemporal image structure at the target location. Contrast discrimination performance can be modeled by assuming that the underlying contrast response is an accelerating nonlinearity (arising from a nonlinear transducer or gain control). We implemented one such model and examined the posterior over model parameters, estimated using Markov-chain Monte Carlo methods. The parameters were poorly constrained by our data; parameters constrained using strong priors taken from previous research showed poor cross-validated prediction performance. Atheoretical logistic regression models were better constrained and provided similar prediction performance to the nonlinear transducer model. Finally, we explored the properties of an extended logistic regression that incorporates both eye movement and image content features. Models of contrast transduction may be better constrained by incorporating data from both artificial and natural contrast perception settings. PMID:26057546

  13. Visual Sensory and Visual-Cognitive Function and Rate of Crash and Near-Crash Involvement Among Older Drivers Using Naturalistic Driving Data

    PubMed Central

    Huisingh, Carrie; Levitan, Emily B.; Irvin, Marguerite R.; MacLennan, Paul; Wadley, Virginia; Owsley, Cynthia

    2017-01-01

    Purpose An innovative methodology using naturalistic driving data was used to examine the association between visual sensory and visual-cognitive function and rates of future crash or near-crash involvement among older drivers. Methods The Strategic Highway Research Program (SHRP2) Naturalistic Driving Study was used for this prospective analysis. The sample consisted of N = 659 drivers aged ≥70 years and study participation lasted 1 or 2 years for most participants. Distance and near visual acuity, contrast sensitivity, peripheral vision, visual processing speed, and visuospatial skills were assessed at baseline. Crash and near-crash involvement were based on video recordings and vehicle sensors. Poisson regression models were used to generate crude and adjusted rate ratios (RRs) and 95% confidence intervals, while accounting for person-miles of travel. Results After adjustment, severe impairment of the useful field of view (RR = 1.33) was associated with an increased rate of near-crash involvement. Crash, severe crash, and at-fault crash involvement were associated with impaired contrast sensitivity in the worse eye (RRs = 1.38, 1.54, and 1.44, respectively) and far peripheral field loss in both eyes (RRs = 1.74, 2.32, and 1.73, respectively). Conclusions Naturalistic driving data suggest that contrast sensitivity in the worse eye and far peripheral field loss in both eyes elevate the rates of crash involvement, and impaired visual processing speed elevates rates of near-crash involvement among older drivers. Naturalistic driving data may ultimately be critical for understanding the relationship between vision and driving safety. PMID:28605807

  14. Unravelling spatiotemporal tree-ring signals in Mediterranean oaks: a variance-covariance modelling approach of carbon and oxygen isotope ratios.

    PubMed

    Shestakova, Tatiana A; Aguilera, Mònica; Ferrio, Juan Pedro; Gutiérrez, Emilia; Voltas, Jordi

    2014-08-01

    Identifying how physiological responses are structured across environmental gradients is critical to understanding in what manner ecological factors determine tree performance. Here, we investigated the spatiotemporal patterns of signal strength of carbon isotope discrimination (Δ(13)C) and oxygen isotope composition (δ(18)O) for three deciduous oaks (Quercus faginea (Lam.), Q. humilis Mill. and Q. petraea (Matt.) Liebl.) and one evergreen oak (Q. ilex L.) co-occurring in Mediterranean forests along an aridity gradient. We hypothesized that contrasting strategies in response to drought would lead to differential climate sensitivities between functional groups. Such differential sensitivities could result in a contrasting imprint on stable isotopes, depending on whether the spatial or temporal organization of tree-ring signals was analysed. To test these hypotheses, we proposed a mixed modelling framework to group isotopic records into potentially homogeneous subsets according to taxonomic or geographical criteria. To this end, carbon and oxygen isotopes were modelled through different variance-covariance structures for the variability among years (at the temporal level) or sites (at the spatial level). Signal-strength parameters were estimated from the outcome of selected models. We found striking differences between deciduous and evergreen oaks in the organization of their temporal and spatial signals. Therefore, the relationships with climate were examined independently for each functional group. While Q. ilex exhibited a large spatial dependence of isotopic signals on the temperature regime, deciduous oaks showed a greater dependence on precipitation, confirming their higher susceptibility to drought. Such contrasting responses to drought among oak types were also observed at the temporal level (interannual variability), with stronger associations with growing-season water availability in deciduous oaks. Thus, our results indicate that Mediterranean deciduous and evergreen oaks constitute two clearly differentiated functional groups in terms of their carbon and water economies, despite co-existing in a wide range of environments. In contrast, deciduous oaks form a rather homogeneous group in terms of climate sensitivity. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Grid-texture mechanisms in human vision: Contrast detection of regular sparse micro-patterns requires specialist templates.

    PubMed

    Baker, Daniel H; Meese, Tim S

    2016-07-27

    Previous work has shown that human vision performs spatial integration of luminance contrast energy, where signals are squared and summed (with internal noise) over area at detection threshold. We tested that model here in an experiment using arrays of micro-pattern textures that varied in overall stimulus area and sparseness of their target elements, where the contrast of each element was normalised for sensitivity across the visual field. We found a power-law improvement in performance with stimulus area, and a decrease in sensitivity with sparseness. While the contrast integrator model performed well when target elements constituted 50-100% of the target area (replicating previous results), observers outperformed the model when texture elements were sparser than this. This result required the inclusion of further templates in our model, selective for grids of various regular texture densities. By assuming a MAX operation across these noisy mechanisms the model also accounted for the increase in the slope of the psychometric function that occurred as texture density decreased. Thus, for the first time, mechanisms that are selective for texture density have been revealed at contrast detection threshold. We suggest that these mechanisms have a role to play in the perception of visual textures.

  16. Grid-texture mechanisms in human vision: Contrast detection of regular sparse micro-patterns requires specialist templates

    PubMed Central

    Baker, Daniel H.; Meese, Tim S.

    2016-01-01

    Previous work has shown that human vision performs spatial integration of luminance contrast energy, where signals are squared and summed (with internal noise) over area at detection threshold. We tested that model here in an experiment using arrays of micro-pattern textures that varied in overall stimulus area and sparseness of their target elements, where the contrast of each element was normalised for sensitivity across the visual field. We found a power-law improvement in performance with stimulus area, and a decrease in sensitivity with sparseness. While the contrast integrator model performed well when target elements constituted 50–100% of the target area (replicating previous results), observers outperformed the model when texture elements were sparser than this. This result required the inclusion of further templates in our model, selective for grids of various regular texture densities. By assuming a MAX operation across these noisy mechanisms the model also accounted for the increase in the slope of the psychometric function that occurred as texture density decreased. Thus, for the first time, mechanisms that are selective for texture density have been revealed at contrast detection threshold. We suggest that these mechanisms have a role to play in the perception of visual textures. PMID:27460430

  17. Hybrid system for in vivo real-time planar fluorescence and volumetric optoacoustic imaging

    NASA Astrophysics Data System (ADS)

    Chen, Zhenyue; Deán-Ben, Xosé Luís.; Gottschalk, Sven; Razansky, Daniel

    2018-02-01

    Fluorescence imaging is widely employed in all fields of cell and molecular biology due to its high sensitivity, high contrast and ease of implementation. However, the low spatial resolution and lack of depth information, especially in strongly-scattering samples, restrict its applicability for deep-tissue imaging applications. On the other hand, optoacoustic imaging is known to deliver a unique set of capabilities such as high spatial and temporal resolution in three dimensions, deep penetration and spectrally-enriched imaging contrast. Since fluorescent substances can generate contrast in both modalities, simultaneous fluorescence and optoacoustic readings can provide new capabilities for functional and molecular imaging of living organisms. Optoacoustic images can further serve as valuable anatomical references based on endogenous hemoglobin contrast. Herein, we propose a hybrid system for in vivo real-time planar fluorescence and volumetric optoacoustic tomography, both operating in reflection mode, which synergistically combines the advantages of stand-alone systems. Validation of the spatial resolution and sensitivity of the system were first carried out in tissue mimicking phantoms while in vivo imaging was further demonstrated by tracking perfusion of an optical contrast agent in a mouse brain in the hybrid imaging mode. Experimental results show that the proposed system effectively exploits the contrast mechanisms of both imaging modalities, making it especially useful for accurate monitoring of fluorescence-based signal dynamics in highly scattering samples.

  18. Capsaicin-sensitive sensory nerves exert complex regulatory functions in the serum-transfer mouse model of autoimmune arthritis.

    PubMed

    Borbély, Éva; Botz, Bálint; Bölcskei, Kata; Kenyér, Tibor; Kereskai, László; Kiss, Tamás; Szolcsányi, János; Pintér, Erika; Csepregi, Janka Zsófia; Mócsai, Attila; Helyes, Zsuzsanna

    2015-03-01

    The K/BxN serum-transfer arthritis is a widely-used translational mouse model of rheumatoid arthritis, in which the immunological components have thoroughly been investigated. In contrast, little is known about the role of sensory neural factors and the complexity of neuro-immune interactions. Therefore, we analyzed the involvement of capsaicin-sensitive peptidergic sensory nerves in autoantibody-induced arthritis with integrative methodology. Arthritogenic K/BxN or control serum was injected to non-pretreated mice or resiniferatoxin (RTX)-pretreated animals where capsaicin-sensitive nerves were inactivated. Edema, touch sensitivity, noxious heat threshold, joint function, body weight and clinical arthritis severity scores were determined repeatedly throughout two weeks. Micro-CT and in vivo optical imaging to determine matrix-metalloproteinase (MMP) and neutrophil-derived myeloperoxidase (MPO) activities, semiquantitative histopathological scoring and radioimmunoassay to measure somatostatin in the joint homogenates were also performed. In RTX-pretreated mice, the autoantibody-induced joint swelling, arthritis severity score, MMP and MPO activities, as well as histopathological alterations were significantly greater compared to non-pretreated animals. Self-control quantification of the bone mass revealed decreased values in intact female mice, but significantly greater arthritis-induced pathological bone formation after RTX-pretreatment. In contrast, mechanical hyperalgesia from day 10 was smaller after inactivating capsaicin-sensitive afferents. Although thermal hyperalgesia did not develop, noxious heat threshold was significantly higher following RTX pretreatment. Somatostatin-like immunoreactivity elevated in the tibiotarsal joints in non-pretreated, which was significantly less in RTX-pretreated mice. Although capsaicin-sensitive sensory nerves mediate mechanical hyperalgesia in the later phase of autoantibody-induced chronic arthritis, they play important anti-inflammatory roles at least partially through somatostatin release. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.

  19. Capsaicin-sensitive sensory nerves exert complex regulatory functions in the serum-transfer mouse model of autoimmune arthritis

    PubMed Central

    Borbély, Éva; Botz, Bálint; Bölcskei, Kata; Kenyér, Tibor; Kereskai, László; Kiss, Tamás; Szolcsányi, János; Pintér, Erika; Csepregi, Janka Zsófia; Mócsai, Attila; Helyes, Zsuzsanna

    2015-01-01

    Objective The K/BxN serum-transfer arthritis is a widely-used translational mouse model of rheumatoid arthritis, in which the immunological components have thoroughly been investigated. In contrast, little is known about the role of sensory neural factors and the complexity of neuro–immune interactions. Therefore, we analyzed the involvement of capsaicin-sensitive peptidergic sensory nerves in autoantibody-induced arthritis with integrative methodology. Methods Arthritogenic K/BxN or control serum was injected to non-pretreated mice or resiniferatoxin (RTX)-pretreated animals where capsaicin-sensitive nerves were inactivated. Edema, touch sensitivity, noxious heat threshold, joint function, body weight and clinical arthritis severity scores were determined repeatedly throughout two weeks. Micro-CT and in vivo optical imaging to determine matrix-metalloproteinase (MMP) and neutrophil-derived myeloperoxidase (MPO) activities, semiquantitative histopathological scoring and radioimmunoassay to measure somatostatin in the joint homogenates were also performed. Results In RTX-pretreated mice, the autoantibody-induced joint swelling, arthritis severity score, MMP and MPO activities, as well as histopathological alterations were significantly greater compared to non-pretreated animals. Self-control quantification of the bone mass revealed decreased values in intact female mice, but significantly greater arthritis-induced pathological bone formation after RTX-pretreatment. In contrast, mechanical hyperalgesia from day 10 was smaller after inactivating capsaicin-sensitive afferents. Although thermal hyperalgesia did not develop, noxious heat threshold was significantly higher following RTX pretreatment. Somatostatin-like immunoreactivity elevated in the tibiotarsal joints in non-pretreated, which was significantly less in RTX-pretreated mice. Conclusions Although capsaicin-sensitive sensory nerves mediate mechanical hyperalgesia in the later phase of autoantibody-induced chronic arthritis, they play important anti-inflammatory roles at least partially through somatostatin release. PMID:25524130

  20. Extreme ultraviolet patterning of tin-oxo cages

    NASA Astrophysics Data System (ADS)

    Haitjema, Jarich; Zhang, Yu; Vockenhuber, Michaela; Kazazis, Dimitrios; Ekinci, Yasin; Brouwer, Albert M.

    2017-07-01

    We report on the extreme ultraviolet (EUV) patterning performance of tin-oxo cages. These cage molecules were already known to function as a negative tone photoresist for EUV radiation, but in this work, we significantly optimized their performance. Our results show that sensitivity and resolution are only meaningful photoresist parameters if the process conditions are optimized. We focus on contrast curves of the materials using large area EUV exposures and patterning of the cages using EUV interference lithography. It is shown that baking steps, such as postexposure baking, can significantly affect both the sensitivity and contrast in the open-frame experiments as well as the patterning experiments. A layer thickness increase reduced the necessary dose to induce a solubility change but decreased the patterning quality. The patterning experiments were affected by minor changes in processing conditions such as an increased rinsing time. In addition, we show that the anions of the cage can influence the sensitivity and quality of the patterning, probably through their effect on physical properties of the materials.

  1. Cell tracking with caged xenon: using cryptophanes as MRI reporters upon cellular internalization.

    PubMed

    Klippel, Stefan; Döpfert, Jörg; Jayapaul, Jabadurai; Kunth, Martin; Rossella, Federica; Schnurr, Matthias; Witte, Christopher; Freund, Christian; Schröder, Leif

    2014-01-07

    Caged xenon has great potential in overcoming sensitivity limitations for solution-state NMR detection of dilute molecules. However, no application of such a system as a magnetic resonance imaging (MRI) contrast agent has yet been performed with live cells. We demonstrate MRI localization of cells labeled with caged xenon in a packed-bed bioreactor working under perfusion with hyperpolarized-xenon-saturated medium. Xenon hosts enable NMR/MRI experiments with switchable contrast and selectivity for cell-associated versus unbound cages. We present MR images with 10(3) -fold sensitivity enhancement for cell-internalized, dual-mode (fluorescence/MRI) xenon hosts at low micromolar concentrations. Our results illustrate the capability of functionalized xenon to act as a highly sensitive cell tracer for MRI detection even without signal averaging. The method will bridge the challenging gap for translation to in vivo studies for the optimization of targeted biosensors and their multiplexing applications. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Exogenous attention enhances 2nd-order contrast sensitivity

    PubMed Central

    Barbot, Antoine; Landy, Michael S.; Carrasco, Marisa

    2011-01-01

    Natural scenes contain a rich variety of contours that the visual system extracts to segregrate the retinal image into perceptually coherent regions. Covert spatial attention helps extract contours by enhancing contrast sensitivity for 1st-order, luminance-defined patterns at attended locations, while reducing sensitivity at unattended locations, relative to neutral attention allocation. However, humans are also sensitive to 2nd-order patterns such as spatial variations of texture, which are predominant in natural scenes and cannot be detected by linear mechanisms. We assess whether and how exogenous attention—the involuntary and transient capture of spatial attention—affects the contrast sensitivity of channels sensitive to 2nd-order, texture-defined patterns. Using 2nd-order, texture-defined stimuli, we demonstrate that exogenous attention increases 2nd-order contrast sensitivity at the attended location, while decreasing it at unattended locations, relative to a neutral condition. By manipulating both 1st- and 2nd-order spatial frequency, we find that the effects of attention depend both on 2nd-order spatial frequency of the stimulus and the observer’s 2nd-order spatial resolution at the target location. At parafoveal locations, attention enhances 2nd-order contrast sensitivity to high, but not to low 2nd-order spatial frequencies; at peripheral locations attention also enhances sensitivity to low 2nd-order spatial frequencies. Control experiments rule out the possibility that these effects might be due to an increase in contrast sensitivity at the 1st-order stage of visual processing. Thus, exogenous attention affects 2nd-order contrast sensitivity at both attended and unattended locations. PMID:21356228

  3. Analysis of the moments of the sensitivity function for resistivity over a homogeneous half-space: Rules of thumb for pseudoposition, offline sensitivity and resolution

    NASA Astrophysics Data System (ADS)

    Butler, S. L.

    2017-08-01

    It is instructive to consider the sensitivity function for a homogeneous half space for resistivity since it has a simple mathematical formula and it does not require a priori knowledge of the resistivity of the ground. Past analyses of this function have allowed visualization of the regions that contribute most to apparent resistivity measurements with given array configurations. The horizontally integrated form of this equation gives the sensitivity function for an infinitesimally thick horizontal slab with a small resistivity contrast and analysis of this function has admitted estimates of the depth of investigation for a given electrode array. Recently, it has been shown that the average of the vertical coordinate over this function yields a simple formula that can be used to estimate the depth of investigation. The sensitivity function for a vertical inline slab has also been previously calculated. In this contribution, I show that the sensitivity function for a homogeneous half-space can also be integrated so as to give sensitivity functions to semi-infinite vertical slabs that are perpendicular to the array axis. These horizontal sensitivity functions can, in turn, be integrated over the spatial coordinates to give the mean horizontal positions of the sensitivity functions. The mean horizontal positions give estimates for the centres of the regions that affect apparent resistivity measurements for arbitrary array configuration and can be used as horizontal positions when plotting pseudosections even for non-collinear arrays. The mean of the horizontal coordinate that is perpendicular to a collinear array also gives a simple formula for estimating the distance over which offline resistivity anomalies will have a significant effect. The root mean square (rms) widths of the sensitivity functions are also calculated in each of the coordinate directions as an estimate of the inverse of the resolution of a given array. For depth and in the direction perpendicular to the array, the rms thickness is shown to be very similar to the mean distance. For the direction parallel to the array, the rms thickness is shown to be proportional to the array length and similar to the array length divided by 2 for many arrays. I expect that these formulas will provide useful rules of thumb for estimating the centres and extents of regions influencing apparent resistivity measurements for survey planning and for education.

  4. Spatial Standard Observer

    NASA Technical Reports Server (NTRS)

    Watson, Andrw B. (Inventor)

    2010-01-01

    The present invention relates to devices and methods for the measurement and/or for the specification of the perceptual intensity of a visual image. or the perceptual distance between a pair of images. Grayscale test and reference images are processed to produce test and reference luminance images. A luminance filter function is convolved with the reference luminance image to produce a local mean luminance reference image . Test and reference contrast images are produced from the local mean luminance reference image and the test and reference luminance images respectively, followed by application of a contrast sensitivity filter. The resulting images are combined according to mathematical prescriptions to produce a Just Noticeable Difference, JND value, indicative of a Spatial Standard Observer. SSO. Some embodiments include masking functions. window functions. special treatment for images lying on or near border and pre-processing of test images.

  5. Spatial Standard Observer

    NASA Technical Reports Server (NTRS)

    Watson, Andrew B. (Inventor)

    2012-01-01

    The present invention relates to devices and methods for the measurement and/or for the specification of the perceptual intensity of a visual image, or the perceptual distance between a pair of images. Grayscale test and reference images are processed to produce test and reference luminance images. A luminance filter function is convolved with the reference luminance image to produce a local mean luminance reference image. Test and reference contrast images are produced from the local mean luminance reference image and the test and reference luminance images respectively, followed by application of a contrast sensitivity filter. The resulting images are combined according to mathematical prescriptions to produce a Just Noticeable Difference, JND value, indicative of a Spatial Standard Observer, SSO. Some embodiments include masking functions, window functions, special treatment for images lying on or near borders and pre-processing of test images.

  6. Temporal voice areas exist in autism spectrum disorder but are dysfunctional for voice identity recognition

    PubMed Central

    Borowiak, Kamila; von Kriegstein, Katharina

    2016-01-01

    The ability to recognise the identity of others is a key requirement for successful communication. Brain regions that respond selectively to voices exist in humans from early infancy on. Currently, it is unclear whether dysfunction of these voice-sensitive regions can explain voice identity recognition impairments. Here, we used two independent functional magnetic resonance imaging studies to investigate voice processing in a population that has been reported to have no voice-sensitive regions: autism spectrum disorder (ASD). Our results refute the earlier report that individuals with ASD have no responses in voice-sensitive regions: Passive listening to vocal, compared to non-vocal, sounds elicited typical responses in voice-sensitive regions in the high-functioning ASD group and controls. In contrast, the ASD group had a dysfunction in voice-sensitive regions during voice identity but not speech recognition in the right posterior superior temporal sulcus/gyrus (STS/STG)—a region implicated in processing complex spectrotemporal voice features and unfamiliar voices. The right anterior STS/STG correlated with voice identity recognition performance in controls but not in the ASD group. The findings suggest that right STS/STG dysfunction is critical for explaining voice recognition impairments in high-functioning ASD and show that ASD is not characterised by a general lack of voice-sensitive responses. PMID:27369067

  7. Multimodal instrument for high-sensitivity autofluorescence and spectral optical coherence tomography of the human eye fundus

    PubMed Central

    Komar, Katarzyna; Stremplewski, Patrycjusz; Motoczyńska, Marta; Szkulmowski, Maciej; Wojtkowski, Maciej

    2013-01-01

    In this paper we present a multimodal device for imaging fundus of human eye in vivo which combines functionality of autofluorescence by confocal SLO with Fourier domain OCT. Native fluorescence of human fundus was excited by modulated laser beam (λ = 473 nm, 20 MHz) and lock-in detection was applied resulting in improving sensitivity. The setup allows for acquisition of high resolution OCT and high contrast AF images using fluorescence excitation power of 50-65 μW without averaging consecutive images. Successful functioning of constructed device have been demonstrated for 8 healthy volunteers of different age ranging from 24 to 83 years old. PMID:24298426

  8. Cutaneous sensitivity in unilateral trans-tibial amputees

    PubMed Central

    Templeton, Cale A.; Strzalkowski, Nicholas D. J.; Galvin, Patti

    2018-01-01

    Aim To examine tactile sensitivity in the leg and foot sole of below-knee amputees (diabetic n = 3, traumatic n = 1), and healthy control subjects (n = 4), and examine the association between sensation and balance. Method Vibration perception threshold (VPT; 3, 40, 250Hz) and monofilaments (MF) were used to examine vibration and light touch sensitivity on the intact limb, residual limb, and homologous locations on controls. A functional reach test was performed to assess functional balance. Results Tactile sensitivity was lower for diabetic amputee subjects compared to age matched controls for both VPT and MF; which was expected due to presence of diabetic peripheral neuropathy. In contrast, the traumatic amputee participant showed increased sensitivity for VPT at 40Hz and 250Hz vibration in both the intact and residual limbs compared to controls. Amputees with lower tactile sensitivity had shorter reach distances compared to those with higher sensitivity. Conclusion Changes in tactile sensitivity in the residual limb of trans-tibial amputees may have implications for the interaction between the amputee and the prosthetic device. The decreased skin sensitivity observed in the residual limb of subjects with diabetes is of concern as changes in skin sensitivity may be important in 1) identification/prevention of excessive pressure and 2) for functional stability. Interestingly, we saw increased residual limb skin sensitivity in the individual with the traumatic amputation. Although not measured directly in the present study, this increase in tactile sensitivity may be related to cortical reorganisation, which is known to occur following amputation, and would support similar findings observed in upper limb amputees. PMID:29856766

  9. Helium ion microscopy of graphene: beam damage, image quality and edge contrast

    NASA Astrophysics Data System (ADS)

    Fox, D.; Zhou, Y. B.; O'Neill, A.; Kumar, S.; Wang, J. J.; Coleman, J. N.; Duesberg, G. S.; Donegan, J. F.; Zhang, H. Z.

    2013-08-01

    A study to analyse beam damage, image quality and edge contrast in the helium ion microscope (HIM) has been undertaken. The sample investigated was graphene. Raman spectroscopy was used to quantify the disorder that can be introduced into the graphene as a function of helium ion dose. The effects of the dose on both freestanding and supported graphene were compared. These doses were then correlated directly to image quality by imaging graphene flakes at high magnification. It was found that a high magnification image with a good signal to noise ratio will introduce very significant sample damage. A safe imaging dose of the order of 1013 He+ cm-2 was established, with both graphene samples becoming highly defective at doses over 5 × 1014 He+ cm-2. The edge contrast of a freestanding graphene flake imaged in the HIM was then compared with the contrast of the same flake observed in a scanning electron microscope and a transmission electron microscope. Very strong edge sensitivity was observed in the HIM. This enhanced edge sensitivity over the other techniques investigated makes the HIM a powerful nanoscale dimensional metrology tool, with the capability of both fabricating and imaging features with sub-nanometre resolution.

  10. Contrast Adaptation Implies Two Spatiotemporal Channels but Three Adapting Processes

    ERIC Educational Resources Information Center

    Langley, Keith; Bex, Peter J.

    2007-01-01

    The contrast gain control model of adaptation predicts that the effects of contrast adaptation correlate with contrast sensitivity. This article reports that the effects of high contrast spatiotemporal adaptors are maximum when adapting around 19 Hz, which is a factor of two or more greater than the peak in contrast sensitivity. To explain the…

  11. Independence and interaction of luminance and chromatic contributions to spatial hyperacuity performance.

    PubMed

    Cooper, Bonnie; Lee, Barry B

    2014-04-01

    Here we test interactions of luminance and chromatic input to spatial hyperacuity mechanisms. First, we tested alignment of luminance and chromatic gratings matched or mismatched in contrast polarity or grating type. Thresholds with matched gratings were low while all mismatched pairs were elevated. Second, we determined alignment acuity as a function of luminance or chromatic contrast alone or in the presence of constant contrast components of the other type. For in-phase components, performance followed the envelope of the more sensitive mechanism. However, polarity reversals revealed an asymmetric effect for luminance and chromatic conditions, which suggested that luminance can override chromatic mechanisms in hyperacuity; we interpret these findings in the context of spatial mechanisms.

  12. Characterizing Perceptual Performance at Multiple Discrimination Precisions in External Noise

    PubMed Central

    Jeon, Seong-Taek; Lu, Zhong-Lin; Dosher, Barbara Anne

    2010-01-01

    Existing observer models developed for studies with the external noise paradigm are strictly only applicable to target detection or identification/discrimination of orthogonal target(s). We elaborated the perceptual template model (PTM) to account for contrast thresholds in identifying non-orthogonal targets. Full contrast psychometric functions were measured in an orientation identification task with four orientation differences across a wide range of external noise levels. We showed that observer performance can be modeled by the elaborated PTM with two templates that correspond to the two stimulus categories. Sampling efficiencies of the human observers were also estimated. The elaborated PTM provides a theoretical framework to characterize joint feature and contrast sensitivity of human observers. PMID:19884915

  13. Functional Assessment of Laser Irradiation

    DTIC Science & Technology

    1988-03-01

    1 Diagram of the Plexiglas restraint device used during laser exposure and acuity testing ........................................... 4 FIGURE 2...8 FIGURE 6 Spectral sensitivity curves for rhesus, human trichromat, and protonomalous human tested under similar...luminance, wavelength and logical means (fundoscopic or histologic verification contrast of test targets have yielded various damac of tissue damage) or can

  14. Understanding the exposure-time effect on speckle contrast measurements for laser displays

    NASA Astrophysics Data System (ADS)

    Suzuki, Koji; Kubota, Shigeo

    2018-02-01

    To evaluate the influence of exposure time on speckle noise for laser displays, speckle contrast measurement method was developed observable at a human eye response time using a high-sensitivity camera which has a signal multiplying function. The nonlinearity of camera light sensitivity was calibrated to measure accurate speckle contrasts, and the measuring lower limit noise of speckle contrast was improved by applying spatial-frequency low pass filter to the captured images. Three commercially available laser displays were measured over a wide range of exposure times from tens of milliseconds to several seconds without adjusting the brightness of laser displays. The speckle contrast of raster-scanned mobile projector without any speckle-reduction device was nearly constant over various exposure times. On the contrary to this, in full-frame projection type laser displays equipped with a temporally-averaging speckle-reduction device, some of their speckle contrasts close to the lower limits noise were slightly increased at the shorter exposure time due to the noise. As a result, the exposure-time effect of speckle contrast could not be observed in our measurements, although it is more reasonable to think that the speckle contrasts of laser displays, which are equipped with the temporally-averaging speckle-reduction device, are dependent on the exposure time. This discrepancy may be attributed to the underestimation of temporal averaging factor. We expected that this method is useful for evaluating various laser displays and clarify the relationship between the speckle noise and the exposure time for a further verification of speckle reduction.

  15. Quality of vision, patient satisfaction and long-term visual function after bilateral implantation of a low addition multifocal intraocular lens.

    PubMed

    Pedrotti, Emilio; Mastropasqua, Rodolfo; Bonetto, Jacopo; Demasi, Christian; Aiello, Francesco; Nucci, Carlo; Mariotti, Cesare; Marchini, Giorgio

    2017-07-17

    The aim of the current study was to compare the quality of vision, contrast sensitivity and patient satisfaction with a biaspheric, segmented, rotationally asymmetric IOL (Lentis Comfort LS-313 MF 15-Oculentis GmbH, Berlin, Germany) as opposed to those of a monofocal IOL. This prospective single-blind comparative study included two groups of patients affected by bilateral senile cataract who underwent lens extraction and IOL implantation. The first group received a bilateral implantation of a monofocal IOL, and the second group received a bilateral implantation of the Comfort IOL. Twelve months after surgery uncorrected and corrected visual acuity at different distances (30, 50, 70 cm and 4 m), defocus curve and contrast sensitivity were assessed. Patient's satisfaction and spectacle independence were evaluated by mean of the NEI RQL-42 questionnaire. No significant differences were found between the groups in terms of near vision. The group of patients implanted with a Comfort IOL obtained the best results at intermediate distances (50 and 70 cm P < .001). Both groups showed an excellent uncorrected distance visual acuity (4 m). No statistically significant differences were found in terms of corrected near, intermediate and distance visual acuity. Concerning contrast sensitivity, no statistically significant differences between the groups were observed at any cycles per degree. The NEI RQL-42 questionnaire showed statistically significant differences between the group for "near vision" (P = .015), "dependence on correction" (P = .048) and "suboptimal correction" (P < .001) subscales. Our findings indicated that the Comfort IOL +1.5 D provides a good intermediate spectacle independence together with a high quality of vision, with a low amount of subjective symptoms and a contrast sensitivity similar to those obtained with a monofocal IOL.

  16. A prospective, contralateral comparison of photorefractive keratectomy (PRK) versus thin-flap LASIK: assessment of visual function.

    PubMed

    Hatch, Bryndon B; Moshirfar, Majid; Ollerton, Andrew J; Sikder, Shameema; Mifflin, Mark D

    2011-01-01

    To compare differences in visual acuity, contrast sensitivity, complications, and higher-order ocular aberrations (HOAs) in eyes with stable myopia undergoing either photo-refractive keratectomy (PRK) or thin-flap laser in situ keratomileusis (LASIK) (intended flap thickness of 90 μm) using the VISX Star S4 CustomVue excimer laser and the IntraLase FS60 femtosecond laser at 1, 3, and 6 months postoperatively. In this prospective, masked, and randomized pilot study, refractive surgery was performed contralaterally on 52 eyes: 26 with PRK and 26 with thin-flap LASIK. Primary outcome measures were uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), contrast sensitivity, and complications. At 6 months, mean values for UDVA (logMAR) were -0.043 ± 0.668 and -0.061 ± 0.099 in the PRK and thin-flap LASIK groups, respectively (n = 25, P = 0.466). UDVA of 20/20 or better was achieved in 96% of eyes undergoing PRK and 92% of eyes undergoing thin-flap LASIK, whereas 20/15 vision or better was achieved in 73% of eyes undergoing PRK and 72% of eyes undergoing thin-flap LASIK (P > 0.600). Significant differences were not found between treatment groups in contrast sensitivity (P ≥ 0.156) or CDVA (P = 0.800) at postoperative 6 months. Types of complications differed between groups, notably 35% of eyes in the thin-flap LASIK group experiencing complications, including microstriae and 2 flap tears. Under well-controlled surgical conditions, PRK and thin-flap LASIK refractive surgeries achieve similar results in visual acuity, contrast sensitivity, and induction of HOAs, with differences in experienced complications.

  17. A prospective, contralateral comparison of photorefractive keratectomy (PRK) versus thin-flap LASIK: assessment of visual function

    PubMed Central

    Hatch, Bryndon B; Moshirfar, Majid; Ollerton, Andrew J; Sikder, Shameema; Mifflin, Mark D

    2011-01-01

    Purpose: To compare differences in visual acuity, contrast sensitivity, complications, and higher-order ocular aberrations (HOAs) in eyes with stable myopia undergoing either photo-refractive keratectomy (PRK) or thin-flap laser in situ keratomileusis (LASIK) (intended flap thickness of 90 μm) using the VISX Star S4 CustomVue excimer laser and the IntraLase FS60 femtosecond laser at 1, 3, and 6 months postoperatively. Methods: In this prospective, masked, and randomized pilot study, refractive surgery was performed contralaterally on 52 eyes: 26 with PRK and 26 with thin-flap LASIK. Primary outcome measures were uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), contrast sensitivity, and complications. Results: At 6 months, mean values for UDVA (logMAR) were −0.043 ± 0.668 and −0.061 ± 0.099 in the PRK and thin-flap LASIK groups, respectively (n = 25, P = 0.466). UDVA of 20/20 or better was achieved in 96% of eyes undergoing PRK and 92% of eyes undergoing thin-flap LASIK, whereas 20/15 vision or better was achieved in 73% of eyes undergoing PRK and 72% of eyes undergoing thin-flap LASIK (P > 0.600). Significant differences were not found between treatment groups in contrast sensitivity (P ≥ 0.156) or CDVA (P = 0.800) at postoperative 6 months. Types of complications differed between groups, notably 35% of eyes in the thin-flap LASIK group experiencing complications, including microstriae and 2 flap tears. Conclusion: Under well-controlled surgical conditions, PRK and thin-flap LASIK refractive surgeries achieve similar results in visual acuity, contrast sensitivity, and induction of HOAs, with differences in experienced complications. PMID:21573091

  18. Brain–heart interactions: challenges and opportunities with functional magnetic resonance imaging at ultra-high field

    PubMed Central

    Raven, Erika P.; Duyn, Jeff H.

    2016-01-01

    Magnetic resonance imaging (MRI) at ultra-high field (UHF) strengths (7 T and above) offers unique opportunities for studying the human brain with increased spatial resolution, contrast and sensitivity. However, its reliability can be compromised by factors such as head motion, image distortion and non-neural fluctuations of the functional MRI signal. The objective of this review is to provide a critical discussion of the advantages and trade-offs associated with UHF imaging, focusing on the application to studying brain–heart interactions. We describe how UHF MRI may provide contrast and resolution benefits for measuring neural activity of regions involved in the control and mediation of autonomic processes, and in delineating such regions based on anatomical MRI contrast. Limitations arising from confounding signals are discussed, including challenges with distinguishing non-neural physiological effects from the neural signals of interest that reflect cardiorespiratory function. We also consider how recently developed data analysis techniques may be applied to high-field imaging data to uncover novel information about brain–heart interactions. PMID:27044994

  19. Brain-heart interactions: challenges and opportunities with functional magnetic resonance imaging at ultra-high field.

    PubMed

    Chang, Catie; Raven, Erika P; Duyn, Jeff H

    2016-05-13

    Magnetic resonance imaging (MRI) at ultra-high field (UHF) strengths (7 T and above) offers unique opportunities for studying the human brain with increased spatial resolution, contrast and sensitivity. However, its reliability can be compromised by factors such as head motion, image distortion and non-neural fluctuations of the functional MRI signal. The objective of this review is to provide a critical discussion of the advantages and trade-offs associated with UHF imaging, focusing on the application to studying brain-heart interactions. We describe how UHF MRI may provide contrast and resolution benefits for measuring neural activity of regions involved in the control and mediation of autonomic processes, and in delineating such regions based on anatomical MRI contrast. Limitations arising from confounding signals are discussed, including challenges with distinguishing non-neural physiological effects from the neural signals of interest that reflect cardiorespiratory function. We also consider how recently developed data analysis techniques may be applied to high-field imaging data to uncover novel information about brain-heart interactions. © 2016 The Author(s).

  20. Visual functions of workers exposed to organic solvents in petrochemical industries

    PubMed Central

    Indhushree, R.; Monica, R.; Coral, K.; Angayarkanni, Narayanasamy; Punitham, R.; Subburathinam, B. M.; Krishnakumar, R.; Santanam, P. P.

    2016-01-01

    Aim: The purpose of this study was to evaluate the visual functions of workers exposed to organic solvents in petrochemical industries. Materials and Methods: Thirty workers from the petroleum refinery and 30 age-matched controls (mean age) were recruited. Visual functions and occupational exposure levels were assessed among both the groups. Visual acuity, contrast sensitivity, color vision, and visual fields were evaluated at the workplace. The biological samples, namely blood and urine, were collected at the workplace and transported to the laboratory for analysis. The urinary excretion of hippuric and methylhippuric acid as well as creatinine was measured by high performance liquid chromatography. Results: The mean age of the workers and controls were 39.7 ± 7.6 years and 38.6 ± 8.1, years respectively. The mean years of experience of the workers were 15.6 ± 6.8 years. Visual acuity was >0.01 LogMAR among both the control and case groups. The contrast sensitivity was reduced at 12cpd among workers. Comparison between groups was done using independent sample t-test. The mean difference in color confusion index was 0.11 ± 0.05 (P = 0.037*). The mean difference in visual fields was −0.31 ± 0.36 dB (P = 0.933). The mean difference in urinary hippuric acid level (urinary metabolite of toluene) between the groups was 0.19 ± 0.96 g/g creatinine (P = 0.049FNx01). The mean difference in the excretion of methylhippuric acid (urinary metabolite of xylene) was 0.06 ± 0.04g/g creatinine (P = 0.154). We also found that exposure was a significant risk factor for color vision defect with an odds ratio of 4.43 (95% CI: 1.36–14.4); P = 0.013. Conclusion: The study results showed that contrast sensitivity and color vision were affected among workers in petrochemical industry. PMID:28446838

  1. Nanoparticle imaging probes for molecular imaging with computed tomography and application to cancer imaging

    NASA Astrophysics Data System (ADS)

    Roeder, Ryan K.; Curtis, Tyler E.; Nallathamby, Prakash D.; Irimata, Lisa E.; McGinnity, Tracie L.; Cole, Lisa E.; Vargo-Gogola, Tracy; Cowden Dahl, Karen D.

    2017-03-01

    Precision imaging is needed to realize precision medicine in cancer detection and treatment. Molecular imaging offers the ability to target and identify tumors, associated abnormalities, and specific cell populations with overexpressed receptors. Nuclear imaging and radionuclide probes provide high sensitivity but subject the patient to a high radiation dose and provide limited spatiotemporal information, requiring combined computed tomography (CT) for anatomic imaging. Therefore, nanoparticle contrast agents have been designed to enable molecular imaging and improve detection in CT alone. Core-shell nanoparticles provide a powerful platform for designing tailored imaging probes. The composition of the core is chosen for enabling strong X-ray contrast, multi-agent imaging with photon-counting spectral CT, and multimodal imaging. A silica shell is used for protective, biocompatible encapsulation of the core composition, volume-loading fluorophores or radionuclides for multimodal imaging, and facile surface functionalization with antibodies or small molecules for targeted delivery. Multi-agent (k-edge) imaging and quantitative molecular imaging with spectral CT was demonstrated using current clinical agents (iodine and BaSO4) and a proposed spectral library of contrast agents (Gd2O3, HfO2, and Au). Bisphosphonate-functionalized Au nanoparticles were demonstrated to enhance sensitivity and specificity for the detection of breast microcalcifications by conventional radiography and CT in both normal and dense mammary tissue using murine models. Moreover, photon-counting spectral CT enabled quantitative material decomposition of the Au and calcium signals. Immunoconjugated Au@SiO2 nanoparticles enabled highly-specific targeting of CD133+ ovarian cancer stem cells for contrast-enhanced detection in model tumors.

  2. Neural responses to various rewards and feedback in the brains of adolescent Internet addicts detected by functional magnetic resonance imaging.

    PubMed

    Kim, Ji-Eun; Son, Jung-Woo; Choi, Won-Hee; Kim, Yeoung-Rang; Oh, Jong-Hyun; Lee, Seungbok; Kim, Jang-Kyu

    2014-06-01

    This study aimed to examine differences in brain activation for various types of reward and feedback in adolescent Internet addicts (AIA) and normal adolescents (NA) using functional magnetic resonance imaging (fMRI). AIA (n = 15) and NA (n = 15) underwent fMRI while performing easy tasks for which performance feedback (PF), social reward (SR) (such as compliments), or monetary reward (MR) was given. Using the no reward (NR) condition, three types of contrasts (PF-NR, SR-NR, and MR-NR) were analyzed. In NA, we observed activation in the reward-related subcortical system, self-related brain region, and other brain areas for the three contrasts, but these brain areas showed almost no activation in AIA. Instead, AIA showed significant activation in the dorsolateral prefrontal cortex for the PF-NR contrast and the negative correlation was found between the level of activation in the left superior temporal gyrus (BA 22) and the duration of Internet game use per day in AIA. These findings suggest that AIA show reduced levels of self-related brain activation and decreased reward sensitivity irrespective of the type of reward and feedback. AIA may be only sensitive to error monitoring regardless of positive feelings, such as sense of satisfaction or achievement. © 2014 The Authors. Psychiatry and Clinical Neurosciences © 2014 Japanese Society of Psychiatry and Neurology.

  3. Temporal Profile of Functional Visual Rehabilitative Outcomes Modulated by Transcranial Direct Current Stimulation (tDCS)

    PubMed Central

    Plow, Ela B.; Obretenova, Souzana N.; Jackson, Mary Lou; Merabet, Lotfi B.

    2012-01-01

    Objectives We have previously reported that transcranial direct current stimulation (tDCS) delivered to the occipital cortex enhances visual functional recovery when combined with 3 months of computer-based rehabilitative training in patients with hemianopia. The principal objective of this study was to evaluate the temporal sequence of effects of tDCS on visual recovery as they appear over the course of training and across different indicators of visual function. Methods Primary objective outcome measures were i) shifts in visual field border and ii) stimulus detection accuracy within the affected hemifield. These were compared between patients randomized to either vision restoration therapy (VRT) combined with active tDCS or VRT paired with sham tDCS. Training comprised of 2 half hour sessions, 3 times a week for 3 months. Primary outcome measures were collected at baseline (pretest), monthly interim intervals, and at posttest (3 months). As secondary outcome measures, contrast sensitivity and reading performance were collected at pretest and posttest time-points only. Results Active tDCS combined with VRT accelerated the recovery of stimulus detection as between-group differences appeared within the first month of training. In contrast, a shift in the visual field border was only evident at posttest (after 3 months of training). TDCS did not affect contrast sensitivity or reading performance. Conclusions These results suggest that tDCS may differentially affect the magnitude and sequence of visual recovery in a manner that is task- specific to the type of visual rehabilitative training strategy employed. PMID:22376226

  4. Repeatability Evaluation of a Contrast Sensitivity System for Transfer to the Eye Clinic

    NASA Astrophysics Data System (ADS)

    Alcalde, N. G.; Castillo, L. R.; Filgueira, C. Paz; Colombo, E. M.

    2016-04-01

    The Contrast Sensitivity Function (CSF) is a valuable tool which can be used to characterize functional vision and also for the diagnosis and management of patients with different eye diseases. In spite of its usefulness, the CSF is currently hardly ever used in clinical practice. The aim of this study was to validate the use of the system called FVC-100 (Tecnovinc-UNT-CONICET, Argentina), which calculates the CSF, in order to transfer this important tool to ophthalmological clinics. The validation was carried out through the design of a repeatability test and the subsequent analysis of the results. Furthermore, we evaluated the impact of different factors influencing the repeatability of the measurements such as age and previous training. The tests were based on the discrimination of sinusoidal gratings for different spatial frequencies (1, 4 and 12 c/°) in both eyes of 12 people, aged between 20 and 70. The results show that the calculated values of SC of each subject have a high repeatability and are not dependent on age or training. These results allow us to conclude positively regarding the effectiveness of the FVC-100, and to validate its use in clinics for the calculation of the FSC as a standard measure of functional vision quality.

  5. Speed, spatial, and temporal tuning of rod and cone vision in mouse.

    PubMed

    Umino, Yumiko; Solessio, Eduardo; Barlow, Robert B

    2008-01-02

    Rods and cones subserve mouse vision over a 100 million-fold range of light intensity (-6 to 2 log cd m(-2)). Rod pathways tune vision to the temporal frequency of stimuli (peak, 0.75 Hz) and cone pathways to their speed (peak, approximately 12 degrees/s). Both pathways tune vision to the spatial components of stimuli (0.064-0.128 cycles/degree). The specific photoreceptor contributions were determined by two-alternative, forced-choice measures of contrast thresholds for optomotor responses of C57BL/6J mice with normal vision, Gnat2(cpfl3) mice without functional cones, and Gnat1-/- mice without functional rods. Gnat2(cpfl3) mice (threshold, -6.0 log cd m(-2)) cannot see rotating gratings above -2.0 log cd m(-2) (photopic vision), and Gnat1-/- mice (threshold, -4.0 log cd m(-2)) are blind below -4.0 log cd m(-2) (scotopic vision). Both genotypes can see in the transitional mesopic range (-4.0 to -2.0 log cd m(-2)). Mouse rod and cone sensitivities are similar to those of human. This parametric study characterizes the functional properties of the mouse visual system, revealing the rod and cone contributions to contrast sensitivity and to the temporal processing of visual stimuli.

  6. Dissociable Roles of Different Types of Working Memory Load in Visual Detection

    PubMed Central

    Konstantinou, Nikos; Lavie, Nilli

    2013-01-01

    We contrasted the effects of different types of working memory (WM) load on detection. Considering the sensory-recruitment hypothesis of visual short-term memory (VSTM) within load theory (e.g., Lavie, 2010) led us to predict that VSTM load would reduce visual-representation capacity, thus leading to reduced detection sensitivity during maintenance, whereas load on WM cognitive control processes would reduce priority-based control, thus leading to enhanced detection sensitivity for a low-priority stimulus. During the retention interval of a WM task, participants performed a visual-search task while also asked to detect a masked stimulus in the periphery. Loading WM cognitive control processes (with the demand to maintain a random digit order [vs. fixed in conditions of low load]) led to enhanced detection sensitivity. In contrast, loading VSTM (with the demand to maintain the color and positions of six squares [vs. one in conditions of low load]) reduced detection sensitivity, an effect comparable with that found for manipulating perceptual load in the search task. The results confirmed our predictions and established a new functional dissociation between the roles of different types of WM load in the fundamental visual perception process of detection. PMID:23713796

  7. Quality of vision in refractive and cataract surgery, indirect measurers: review article.

    PubMed

    Parede, Taís Renata Ribeira; Torricelli, André Augusto Miranda; Mukai, Adriana; Vieira Netto, Marcelo; Bechara, Samir Jacob

    2013-01-01

    Visual acuity is the measurement of an individual's ability to recognize details of an object in a space. Visual function measurements in clinical ophthalmology are limited by factors such as maximum contrast and so it might not adequately reflect the real vision conditions at that moment as well as the subjective aspects of the world perception by the patient. The objective of a successful vision-restoring surgery lies not only in gaining visual acuity lines, but also in vision quality. Therefore, refractive and cataract surgeries have the responsibility of achieving quality results. It is difficult to define quality of vision by a single parameter, and the main functional-vision tests are: contrast sensitivity, disability glare, intraocular stray light and aberrometry. In the current review the different components of the visual function are explained and the several available methods to assess the vision quality are described.

  8. WE-H-207A-09: Theoretical Limits to Molecular Biomarker Detection Using Magnetic Nanoparticles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weaver, J; Geisel School of Medicine, Dartmouth College, Hanover, NH

    Purpose: Estimate the limits of molecular biomarker detection using magnetic nanoparticle methods like in vivo ELISA. Methods: Magnetic nanoparticles in an alternating magnetic field produce a magnetization that can be detected at exceedingly low levels because the signal at the harmonic frequencies is uniquely produced by the nanoparticles. Because the magnetization can also be used to characterize the nanoparticle rotational freedom, the bound state can be found. If the nanoparticles are coated with molecules that bind the desired biomarker, the rotational freedom reflects the biomarker concentration. The irreducible noise limit is the thermal noise or Johnson noise of the tissuemore » and the contrast that can be measured must be larger than that limit. The contrast produced is a function of the applied field and depends strongly on nanoparticle volume. We have estimated the contrast using a Langevin function of a single composite variable to approximate the full stochastic Langevin equation for nanoparticle dynamics. Results: The thermal noise for a bandwidth reasonable for spectroscopy suggests mid zeptomolar (10–21) to low attomolar (10–18) concentrations can be measured in a volume that is 10cm in scale. The suggested sensitivity is far below the physiologically concentrations of almost all critical biomarkers including cytokines (picomolar), hormones (nanomolar) and heat shock proteins. Conclusion: The sensitivity of in vivo ELISA concentration measurements should be sufficient to measure physiological concentrations of critical biomarkers like cytokines in vivo. Further the sensitivity should be sufficient to measure concentrations of other biomarkers that are six to eight orders of magnitude lower in concentration than immune signaling molecules like cytokines. NIH - 1U54CA151662-01 Department of Radiology.« less

  9. Photobiomodulation reduces drusen volume and improves visual acuity and contrast sensitivity in dry age-related macular degeneration.

    PubMed

    Merry, Graham F; Munk, Marion R; Dotson, Robert S; Walker, Michael G; Devenyi, Robert G

    2017-06-01

    To evaluate the efficacy of photobiomodulation (PBM) treatment for patients with dry age-related macular degeneration (AMD). Assessments on 42 eyes with dry AMD (age related eye disease study (AREDS) 2-4) were conducted. Multiwavelength light emitting diode (LED) light comprising of yellow (590 nm), red (670 nm) and near-infrared (790 nm) bandwidths was applied to subjects' eyes for a treatment course of 3 weeks. Outcome measures were changes in best-corrected visual acuity (BCVA), contrast sensitivity (CS), drusen volume and central drusen thickness. Significant improvement in mean BCVA of 5.90 letters (p < 0.001) was seen on completion of the 3-week treatment and 5.14 letters (p < 0.001) after 3 months. Contrast sensitivity improved significantly (log unit improvement of 0.11 (p = 0.02) at 3 weeks and 3 months (log unit improvement of 0.16 (p = 0.02) at three cycles per degree. Drusen volume decreased by 0.024 mm 3 (p < 0.001) and central drusen thickness was significantly reduced by a mean of 3.78 μm (p < 0.001), while overall central retinal thickness and retinal volume remained stable. This is the first study demonstrating improvements in functional and anatomical outcomes in dry AMD subjects with PBM therapy. These findings corroborate an earlier pilot study that looked at functional outcome measures. The addition of anatomical evidence contributes to the basis for further development of a non-invasive PBM treatment for dry AMD. © 2016 The Authors. Acta Ophthalmologica published by John Wiley & Sons Ltd on behalf of Acta Ophthalmologica Scandinavica Foundation.

  10. Dynamic contrast-enhanced optical imaging of in vivo organ function

    NASA Astrophysics Data System (ADS)

    Amoozegar, Cyrus B.; Wang, Tracy; Bouchard, Matthew B.; McCaslin, Addason F. H.; Blaner, William S.; Levenson, Richard M.; Hillman, Elizabeth M. C.

    2012-09-01

    Conventional approaches to optical small animal molecular imaging suffer from poor resolution, limited sensitivity, and unreliable quantitation, often reducing their utility in practice. We previously demonstrated that the in vivo dynamics of an injected contrast agent could be exploited to provide high-contrast anatomical registration, owing to the temporal differences in each organ's response to the circulating fluorophore. This study extends this approach to explore whether dynamic contrast-enhanced optical imaging (DyCE) can allow noninvasive, in vivo assessment of organ function by quantifying the differing cellular uptake or wash-out dynamics of an agent in healthy and damaged organs. Specifically, we used DyCE to visualize and measure the organ-specific uptake dynamics of indocyanine green before and after induction of transient liver damage. DyCE imaging was performed longitudinally over nine days, and blood samples collected at each imaging session were analyzed for alanine aminotransferase (ALT), a liver enzyme assessed clinically as a measure of liver damage. We show that changes in DyCE-derived dynamics of liver and kidney dye uptake caused by liver damage correlate linearly with ALT concentrations, with an r2 value of 0.91. Our results demonstrate that DyCE can provide quantitative, in vivo, longitudinal measures of organ function with inexpensive and simple data acquisition.

  11. Population receptive field (pRF) measurements of chromatic responses in human visual cortex using fMRI.

    PubMed

    Welbourne, Lauren E; Morland, Antony B; Wade, Alex R

    2018-02-15

    The spatial sensitivity of the human visual system depends on stimulus color: achromatic gratings can be resolved at relatively high spatial frequencies while sensitivity to isoluminant color contrast tends to be more low-pass. Models of early spatial vision often assume that the receptive field size of pattern-sensitive neurons is correlated with their spatial frequency sensitivity - larger receptive fields are typically associated with lower optimal spatial frequency. A strong prediction of this model is that neurons coding isoluminant chromatic patterns should have, on average, a larger receptive field size than neurons sensitive to achromatic patterns. Here, we test this assumption using functional magnetic resonance imaging (fMRI). We show that while spatial frequency sensitivity depends on chromaticity in the manner predicted by behavioral measurements, population receptive field (pRF) size measurements show no such dependency. At any given eccentricity, the mean pRF size for neuronal populations driven by luminance, opponent red/green and S-cone isolating contrast, are identical. Changes in pRF size (for example, an increase with eccentricity and visual area hierarchy) are also identical across the three chromatic conditions. These results suggest that fMRI measurements of receptive field size and spatial resolution can be decoupled under some circumstances - potentially reflecting a fundamental dissociation between these parameters at the level of neuronal populations. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  12. Rhythmic Oscillations of Visual Contrast Sensitivity Synchronized with Action

    PubMed Central

    Tomassini, Alice; Spinelli, Donatella; Jacono, Marco; Sandini, Giulio; Morrone, Maria Concetta

    2016-01-01

    It is well known that the motor and the sensory systems structure sensory data collection and cooperate to achieve an efficient integration and exchange of information. Increasing evidence suggests that both motor and sensory functions are regulated by rhythmic processes reflecting alternating states of neuronal excitability, and these may be involved in mediating sensory-motor interactions. Here we show an oscillatory fluctuation in early visual processing time locked with the execution of voluntary action, and, crucially, even for visual stimuli irrelevant to the motor task. Human participants were asked to perform a reaching movement toward a display and judge the orientation of a Gabor patch, near contrast threshold, briefly presented at random times before and during the reaching movement. When the data are temporally aligned to the onset of movement, visual contrast sensitivity oscillates with periodicity within the theta band. Importantly, the oscillations emerge during the motor planning stage, ~500 ms before movement onset. We suggest that brain oscillatory dynamics may mediate an automatic coupling between early motor planning and early visual processing, possibly instrumental in linking and closing up the visual-motor control loop. PMID:25948254

  13. [Perceptual sharpness metric for visible and infrared color fusion images].

    PubMed

    Gao, Shao-Shu; Jin, Wei-Qi; Wang, Xia; Wang, Ling-Xue; Luo, Yuan

    2012-12-01

    For visible and infrared color fusion images, objective sharpness assessment model is proposed to measure the clarity of detail and edge definition of the fusion image. Firstly, the contrast sensitivity functions (CSF) of the human visual system is used to reduce insensitive frequency components under certain viewing conditions. Secondly, perceptual contrast model, which takes human luminance masking effect into account, is proposed based on local band-limited contrast model. Finally, the perceptual contrast is calculated in the region of interest (contains image details and edges) in the fusion image to evaluate image perceptual sharpness. Experimental results show that the proposed perceptual sharpness metrics provides better predictions, which are more closely matched to human perceptual evaluations, than five existing sharpness (blur) metrics for color images. The proposed perceptual sharpness metrics can evaluate the perceptual sharpness for color fusion images effectively.

  14. The Human Face: A View From the Infant's Eye.

    ERIC Educational Resources Information Center

    Souther, Arthur F.; Banks, Martin S.

    This study explores the reason why very young infants are unable to respond differentially to faces and the cause for developmental changes in infant face perception by age 3 months. Linear systems analysis (LSA) and the contrast sensitivity function (CSF) were used to estimate the facial pattern information available to 1- and 3-month-old…

  15. Contrast Sensitivity for Motion Detection and Direction Discrimination in Adolescents with Autism Spectrum Disorders and Their Siblings

    ERIC Educational Resources Information Center

    Koh, Hwan Cui; Milne, Elizabeth; Dobkins, Karen

    2010-01-01

    The magnocellular (M) pathway hypothesis proposes that impaired visual motion perception observed in individuals with Autism Spectrum Disorders (ASD) might be mediated by atypical functioning of the subcortical M pathway, as this pathway provides the bulk of visual input to cortical motion detectors. To test this hypothesis, we measured luminance…

  16. Identification and classification of genes required for tolerance to freeze-thaw stress revealed by genome-wide screening of Saccharomyces cerevisiae deletion strains.

    PubMed

    Ando, Akira; Nakamura, Toshihide; Murata, Yoshinori; Takagi, Hiroshi; Shima, Jun

    2007-03-01

    Yeasts used in bread making are exposed to freeze-thaw stress during frozen-dough baking. To clarify the genes required for freeze-thaw tolerance, genome-wide screening was performed using the complete deletion strain collection of diploid Saccharomyces cerevisiae. The screening identified 58 gene deletions that conferred freeze-thaw sensitivity. These genes were then classified based on their cellular function and on the localization of their products. The results showed that the genes required for freeze-thaw tolerance were frequently involved in vacuole functions and cell wall biogenesis. The highest numbers of gene products were components of vacuolar H(+)-ATPase. Next, the cross-sensitivity of the freeze-thaw-sensitive mutants to oxidative stress and to cell wall stress was studied; both of these are environmental stresses closely related to freeze-thaw stress. The results showed that defects in the functions of vacuolar H(+)-ATPase conferred sensitivity to oxidative stress and to cell wall stress. In contrast, defects in gene products involved in cell wall assembly conferred sensitivity to cell wall stress but not to oxidative stress. Our results suggest the presence of at least two different mechanisms of freeze-thaw injury: oxidative stress generated during the freeze-thaw process, and defects in cell wall assembly.

  17. Brain imaging of pain sensitization in patients with knee osteoarthritis.

    PubMed

    Pujol, Jesus; Martínez-Vilavella, Gerard; Llorente-Onaindia, Jone; Harrison, Ben J; López-Solà, Marina; López-Ruiz, Marina; Blanco-Hinojo, Laura; Benito, Pere; Deus, Joan; Monfort, Jordi

    2017-09-01

    A relevant aspect in osteoarthritic pain is neural sensitization. This phenomenon involves augmented responsiveness to painful stimulation and may entail a clinically worse prognosis. We used functional magnetic resonance imaging (fMRI) to study pain sensitization in patients with knee osteoarthritis. Sixty patients were recruited and pain sensitization was clinically defined on the basis of regional spreading of pain (spreading sensitization) and increased pain response to repeated stimulation (temporal summation). Functional magnetic resonance imaging testing involved assessing brain responses to both pressure and heat stimulation. Thirty-three patients (55%) showed regional pain spreading (simple sensitization) and 19 patients (32%) showed both regional spreading and temporal summation. Sensitized patients were more commonly women. Direct painful pressure stimulation of the joint (articular interline) robustly activated all of the neural elements typically involved in pain perception, but did not differentiate sensitized and nonsensitized patients. Painful pressure stimulation on the anterior tibial surface (sensitized site) evoked greater activation in sensitized patients in regions typically involved in pain and also beyond these regions, extending to the auditory, visual, and ventral sensorimotor cortices. Painful heat stimulation of the volar forearm did not discriminate the sensitization phenomenon. Results confirm the high prevalence of pain sensitization secondary to knee osteoarthritis. Relevantly, the sensitization phenomenon was associated with neural changes extending beyond strict pain-processing regions with enhancement of activity in general sensory, nonnociceptive brain areas. This effect is in contrast to the changes previously identified in primary pain sensitization in fibromyalgia patients presenting with a weakening of the general sensory integration.

  18. Quantitative evaluation of contrast-enhanced ultrasound after intravenous administration of a microbubble contrast agent for differentiation of benign and malignant thyroid nodules: assessment of diagnostic accuracy.

    PubMed

    Nemec, Ursula; Nemec, Stefan F; Novotny, Clemens; Weber, Michael; Czerny, Christian; Krestan, Christian R

    2012-06-01

    To investigate the diagnostic accuracy, through quantitative analysis, of contrast-enhanced ultrasound (CEUS), using a microbubble contrast agent, in the differentiation of thyroid nodules. This prospective study enrolled 46 patients with solitary, scintigraphically non-functional thyroid nodules. These patients were scheduled for surgery and underwent preoperative CEUS with pulse-inversion harmonic imaging after intravenous microbubble contrast medium administration. Using histology as a standard of reference, time-intensity curves of benign and malignant nodules were compared by means of peak enhancement and wash-out enhancement relative to the baseline intensity using a mixed model ANOVA. ROC analysis was performed to assess the diagnostic accuracy in the differentiation of benign and malignant nodules on CEUS. The complete CEUS data of 42 patients (31/42 [73.8%] benign and 11/42 [26.2%] malignant nodules) revealed a significant difference (P < 0.001) in enhancement between benign and malignant nodules. Furthermore, based on ROC analysis, CEUS demonstrated sensitivity of 76.9%, specificity of 84.8% and accuracy of 82.6%. Quantitative analysis of CEUS using a microbubble contrast agent allows the differentiation of benign and malignant thyroid nodules and may potentially serve, in addition to grey-scale and Doppler ultrasound, as an adjunctive tool in the assessment of patients with thyroid nodules. • Contrast-enhanced ultrasound (CEUS) helps differentiate between benign and malignant thyroid nodules. • Quantitative CEUS analysis yields sensitivity of 76.9% and specificity of 84.8%. • CEUS may be a potentially useful adjunct in assessing thyroid nodules.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schultz, A.W.; Leavitt, W.Z.

    A preliminary study was conducted to determine the feasiblllty of uslng neutron radiography for examining ordnance materials. Depleted U and 4140 steel castings in various thicknesses were examined. In addition, a thin section of Be, a grasshopper and a cricket were radiographed to illustrate the ability of neutrons to determine defects in low-density materials. For uranium thicknesses up to 5 in., a contrast sensitivity between 1.5 and 7.5%o was obtained using thermal neutrons, In foil, and industrial x-ray film transfer techniques. For 6 in. of U, a contrast sensitivity between 6.3 and 12.5% was obtained. For U thicknesses up tomore » 6 in., a detail sensitivity of 2.1% was obtained. For thicknesses up to 4 in. of steel, a contrast sensitivity between 1.9 and 9.4% and a detail sensitivity between 0.8 and 3.1% were obtained. For 5.125 and 6 in. of steel, contrast sensitivities between 14.6 and 29.2% and 14.6 and 39.6%, respectively, and detail sensitivities of no less than 4.9% were obtained. Both a contrast and a detail sensitivity of about 5% were obtained in examining a thin section of Be. Recommendations for further studies are given. (auth)« less

  20. Diffuse correlation tomography in the transport regime: A theoretical study of the sensitivity to Brownian motion.

    PubMed

    Tricoli, Ugo; Macdonald, Callum M; Durduran, Turgut; Da Silva, Anabela; Markel, Vadim A

    2018-02-01

    Diffuse correlation tomography (DCT) uses the electric-field temporal autocorrelation function to measure the mean-square displacement of light-scattering particles in a turbid medium over a given exposure time. The movement of blood particles is here estimated through a Brownian-motion-like model in contrast to ordered motion as in blood flow. The sensitivity kernel relating the measurable field correlation function to the mean-square displacement of the particles can be derived by applying a perturbative analysis to the correlation transport equation (CTE). We derive an analytical expression for the CTE sensitivity kernel in terms of the Green's function of the radiative transport equation, which describes the propagation of the intensity. We then evaluate the kernel numerically. The simulations demonstrate that, in the transport regime, the sensitivity kernel provides sharper spatial information about the medium as compared with the correlation diffusion approximation. Also, the use of the CTE allows one to explore some additional degrees of freedom in the data such as the collimation direction of sources and detectors. Our results can be used to improve the spatial resolution of DCT, in particular, with applications to blood flow imaging in regions where the Brownian motion is dominant.

  1. Diffuse correlation tomography in the transport regime: A theoretical study of the sensitivity to Brownian motion

    NASA Astrophysics Data System (ADS)

    Tricoli, Ugo; Macdonald, Callum M.; Durduran, Turgut; Da Silva, Anabela; Markel, Vadim A.

    2018-02-01

    Diffuse correlation tomography (DCT) uses the electric-field temporal autocorrelation function to measure the mean-square displacement of light-scattering particles in a turbid medium over a given exposure time. The movement of blood particles is here estimated through a Brownian-motion-like model in contrast to ordered motion as in blood flow. The sensitivity kernel relating the measurable field correlation function to the mean-square displacement of the particles can be derived by applying a perturbative analysis to the correlation transport equation (CTE). We derive an analytical expression for the CTE sensitivity kernel in terms of the Green's function of the radiative transport equation, which describes the propagation of the intensity. We then evaluate the kernel numerically. The simulations demonstrate that, in the transport regime, the sensitivity kernel provides sharper spatial information about the medium as compared with the correlation diffusion approximation. Also, the use of the CTE allows one to explore some additional degrees of freedom in the data such as the collimation direction of sources and detectors. Our results can be used to improve the spatial resolution of DCT, in particular, with applications to blood flow imaging in regions where the Brownian motion is dominant.

  2. Die Fledermaus: Regarding Optokinetic Contrast Sensitivity and Light-Adaptation, Chicks Are Mice with Wings

    PubMed Central

    Shi, Qing; Stell, William K.

    2013-01-01

    Background Through adaptation, animals can function visually under an extremely broad range of light intensities. Light adaptation starts in the retina, through shifts in photoreceptor sensitivity and kinetics plus modulation of visual processing in retinal circuits. Although considerable research has been conducted on retinal adaptation in nocturnal species with rod-dominated retinas, such as the mouse, little is known about how cone-dominated avian retinas adapt to changes in mean light intensity. Methodology/Principal Findings We used the optokinetic response to characterize contrast sensitivity (CS) in the chick retina as a function of spatial frequency and temporal frequency at different mean light intensities. We found that: 1) daytime, cone-driven CS was tuned to spatial frequency; 2) nighttime, presumably rod-driven CS was tuned to temporal frequency and spatial frequency; 3) daytime, presumably cone-driven CS at threshold intensity was invariant with temporal and spatial frequency; and 4) daytime photopic CS was invariant with clock time. Conclusion/Significance Light- and dark-adaptational changes in CS were investigated comprehensively for the first time in the cone-dominated retina of an avian, diurnal species. The chick retina, like the mouse retina, adapts by using a “day/night” or “cone/rod” switch in tuning preference during changes in lighting conditions. The chick optokinetic response is an attractive model for noninvasive, behavioral studies of adaptation in retinal circuitry in health and disease. PMID:24098693

  3. Factorizing the motion sensitivity function into equivalent input noise and calculation efficiency.

    PubMed

    Allard, Rémy; Arleo, Angelo

    2017-01-01

    The photopic motion sensitivity function of the energy-based motion system is band-pass peaking around 8 Hz. Using an external noise paradigm to factorize the sensitivity into equivalent input noise and calculation efficiency, the present study investigated if the variation in photopic motion sensitivity as a function of the temporal frequency is due to a variation of equivalent input noise (e.g., early temporal filtering) or calculation efficiency (ability to select and integrate motion). For various temporal frequencies, contrast thresholds for a direction discrimination task were measured in presence and absence of noise. Up to 15 Hz, the sensitivity variation was mainly due to a variation of equivalent input noise and little variation in calculation efficiency was observed. The sensitivity fall-off at very high temporal frequencies (from 15 to 30 Hz) was due to a combination of a drop of calculation efficiency and a rise of equivalent input noise. A control experiment in which an artificial temporal integration was applied to the stimulus showed that an early temporal filter (generally assumed to affect equivalent input noise, not calculation efficiency) could impair both the calculation efficiency and equivalent input noise at very high temporal frequencies. We conclude that at the photopic luminance intensity tested, the variation of motion sensitivity as a function of the temporal frequency was mainly due to early temporal filtering, not to the ability to select and integrate motion. More specifically, we conclude that photopic motion sensitivity at high temporal frequencies is limited by internal noise occurring after the transduction process (i.e., neural noise), not by quantal noise resulting from the probabilistic absorption of photons by the photoreceptors as previously suggested.

  4. The dependence of binocular contrast sensitivities on binocular single vision in normal and amblyopic human subjects

    PubMed Central

    Hood, A S; Morrison, J D

    2002-01-01

    We have measured monocular and binocular contrast sensitivities in response to medium to high spatial frequencies of vertical sinusoidal grating patterns in normal subjects, anisometropic amblyopes, strabismic amblyopes and non-amblyopic esotropes. On binocular viewing, contrast sensitivities were slightly but significantly increased in normal subjects, markedly increased in anisometropes and esotropes with anomalous binocular single vision (BSV) and significantly reduced in esotropes and exotropes without BSV. Application of a prismatic correction to the strabismic eye in order to achieve bifoveal stimulation resulted in a significant reduction in contrast sensitivity in esotropes with and without anomalous BSV, in exotropes and in non-amblyopic esotropes. Control experiments in normal subjects with monocular viewing showed that degradative effects of the prism occurred only with high prism powers and at high spatial frequencies, thus establishing that the reduced contrast sensitivities were the consequence of bifoveal stimulation rather than optical degradation. Displacement of the image of the grating pattern by 2 deg in normal subjects and anisometropes by a dichoptic method to simulate a small angle esotropia had no effect on the contrast sensitivities recorded through the companion eye. By contrast, esotropes showed similar reductions in contrast sensitivity to those obtained with the prism experiments, confirming a fundamental difference between subjects with normal and abnormal ocular alignments. The results have thus established a suppressive action of the fovea of the amblyopic eye acting on the companion, non-amblyopic eye and indicate that correction of ocular misalignments in adult esotropes may be disadvantageous to binocular visual performance. PMID:11956347

  5. High-sensitivity detection of breast tumors in vivo by use of a pH-sensitive near-infrared fluorescence probe

    NASA Astrophysics Data System (ADS)

    Mathejczyk, Julia Eva; Pauli, Jutta; Dullin, Christian; Resch-Genger, Ute; Alves, Frauke; Napp, Joanna

    2012-07-01

    We investigated the potential of the pH-sensitive dye, CypHer5E, conjugated to Herceptin (pH-Her) for the sensitive detection of breast tumors in mice using noninvasive time-domain near-infrared fluorescence imaging and different methods of data analysis. First, the fluorescence properties of pH-Her were analyzed as function of pH and/or dye-to-protein ratio, and binding specificity was confirmed in cell-based assays. Subsequently, the performance of pH-Her in nude mice bearing orthotopic HER2-positive (KPL-4) and HER2-negative (MDA-MB-231) breast carcinoma xenografts was compared to that of an always-on fluorescent conjugate Alexa Fluor 647-Herceptin (Alexa-Her). Subtraction of autofluorescence and lifetime (LT)-gated image analyses were performed for background fluorescence suppression. In mice bearing HER2-positive tumors, autofluorescence subtraction together with the selective fluorescence enhancement of pH-Her solely in the tumor's acidic environment provided high contrast-to-noise ratios (CNRs). This led to an improved sensitivity of tumor detection compared to Alexa-Her. In contrast, LT-gated imaging using LTs determined in model systems did not improve tumor-detection sensitivity in vivo for either probe. In conclusion, pH-Her is suitable for sensitive in vivo monitoring of HER2-expressing breast tumors with imaging in the intensity domain and represents a promising tool for detection of weak fluorescent signals deriving from small tumors or metastases.

  6. Sensitivity of high-frequency Rayleigh-wave data revisited

    USGS Publications Warehouse

    Xia, J.; Miller, R.D.; Ivanov, J.

    2007-01-01

    Rayleigh-wave phase velocity of a layered earth model is a function of frequency and four groups of earth properties: P-wave velocity, S-wave velocity (Vs), density, and thickness of layers. Analysis of the Jacobian matrix (or the difference method) provides a measure of dispersion curve sensitivity to earth properties. Vs is the dominant influence for the fundamental mode (Xia et al., 1999) and higher modes (Xia et al., 2003) of dispersion curves in a high frequency range (>2 Hz) followed by layer thickness. These characteristics are the foundation of determining S-wave velocities by inversion of Rayleigh-wave data. More applications of surface-wave techniques show an anomalous velocity layer such as a high-velocity layer (HVL) or a low-velocity layer (LVL) commonly exists in near-surface materials. Spatial location (depth) of an anomalous layer is usually the most important information that surface-wave techniques are asked to provide. Understanding and correctly defining the sensitivity of high-frequency Rayleigh-wave data due to depth of an anomalous velocity layer are crucial in applying surface-wave techniques to obtain a Vs profile and/or determine the depth of an anomalous layer. Because depth is not a direct earth property of a layered model, changes in depth will result in changes in other properties. Modeling results show that sensitivity at a given depth calculated by the difference method is dependent on the Vs difference (contrast) between an anomalous layer and surrounding layers. The larger the contrast is, the higher the sensitivity due to depth of the layer. Therefore, the Vs contrast is a dominant contributor to sensitivity of Rayleigh-wave data due to depth of an anomalous layer. Modeling results also suggest that the most sensitive depth for an HVL is at about the middle of the depth to the half-space, but for an LVL it is near the ground surface. ?? 2007 Society of Exploration Geophysicists.

  7. Reconstruction of 2D PET data with Monte Carlo generated system matrix for generalized natural pixels

    NASA Astrophysics Data System (ADS)

    Vandenberghe, Stefaan; Staelens, Steven; Byrne, Charles L.; Soares, Edward J.; Lemahieu, Ignace; Glick, Stephen J.

    2006-06-01

    In discrete detector PET, natural pixels are image basis functions calculated from the response of detector pairs. By using reconstruction with natural pixel basis functions, the discretization of the object into a predefined grid can be avoided. Here, we propose to use generalized natural pixel reconstruction. Using this approach, the basis functions are not the detector sensitivity functions as in the natural pixel case but uniform parallel strips. The backprojection of the strip coefficients results in the reconstructed image. This paper proposes an easy and efficient way to generate the matrix M directly by Monte Carlo simulation. Elements of the generalized natural pixel system matrix are formed by calculating the intersection of a parallel strip with the detector sensitivity function. These generalized natural pixels are easier to use than conventional natural pixels because the final step from solution to a square pixel representation is done by simple backprojection. Due to rotational symmetry in the PET scanner, the matrix M is block circulant and only the first blockrow needs to be stored. Data were generated using a fast Monte Carlo simulator using ray tracing. The proposed method was compared to a listmode MLEM algorithm, which used ray tracing for doing forward and backprojection. Comparison of the algorithms with different phantoms showed that an improved resolution can be obtained using generalized natural pixel reconstruction with accurate system modelling. In addition, it was noted that for the same resolution a lower noise level is present in this reconstruction. A numerical observer study showed the proposed method exhibited increased performance as compared to a standard listmode EM algorithm. In another study, more realistic data were generated using the GATE Monte Carlo simulator. For these data, a more uniform contrast recovery and a better contrast-to-noise performance were observed. It was observed that major improvements in contrast recovery were obtained with MLEM when the correct system matrix was used instead of simple ray tracing. The correct modelling was the major cause of improved contrast for the same background noise. Less important factors were the choice of the algorithm (MLEM performed better than ART) and the basis functions (generalized natural pixels gave better results than pixels).

  8. Fabrication and evaluation of tumor-targeted positive MRI contrast agent based on ultrasmall MnO nanoparticles.

    PubMed

    Huang, Haitao; Yue, Tao; Xu, Ke; Golzarian, Jafar; Yu, Jiahui; Huang, Jin

    2015-07-01

    Gd(III) chelate is currently used as positive magnetic resonance imaging (MRI) contrast agent in clinical diagnosis, but generally induces the risk of nephrogenic systemic fibrosis (NSF) due to the dissociated Gd(3+) from Gd(III) chelates. To develop a novel positive MRI contrast agent with low toxicity and high sensitivity, ultrasmall MnO nanoparticles were PEGylated via catechol-Mn chelation and conjugated with cRGD as active targeting function to tumor. Particularly, the MnO nanoparticles with a size of ca. 5nm were modified by α,β-poly(aspartic acid)-based graft polymer containing PEG and DOPA moieties and, meanwhile, conjugated with cRGD to produce the contrast agent with a size of ca. 100nm and a longitudinal relaxivity (r1) of 10.2mM(-1)S(-1). Such nanoscaled contrast agent integrated passive- and active-targeting function to tumor, and its efficient accumulation behavior in tumor was verified by in vivo distribution study. At the same time, the PEG moiety played a role of hydrophilic coating to improve the biocompatibility and stability under storing and physiological conditions, and especially might guarantee enough circulation time in blood. Moreover, in vivo MRI revealed a good and long-term effect of enhancing MRI signal for as-fabricated contrast agent while cell viability assay proved its acceptable cytotoxicity for MRI application. On the whole, the as-fabricated PEGylated and cRGD-functionalized contrast agent based on ultrasmall MnO nanoparticles showed a great potential to the T1-weighted MRI diagnosis of tumor. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.

  9. Extending the the behavioral immune system to political psychology: are political conservatism and disgust sensitivity really related?

    PubMed

    Tybur, Joshua M; Merriman, Leslie A; Hooper, Ann E Caldwell; McDonald, Melissa M; Navarrete, Carlos David

    2010-10-26

    Previous research suggests that several individual and cultural level attitudes, cognitions, and societal structures may have evolved to mitigate the pathogen threats posed by intergroup interactions. It has been suggested that these anti-pathogen defenses are at the root of conservative political ideology. Here, we test a hypothesis that political conservatism functions as a pathogen-avoidance strategy. Across three studies, we consistently find no relationship between sensitivity to pathogen disgust and multiple measures of political conservatism. These results are contrasted with theoretical perspectives suggesting a relationship between conservatism and pathogen avoidance, and with previous findings of a relationship between conservatism and disgust sensitivity.

  10. Is improved contrast sensitivity a natural consequence of visual training?

    PubMed Central

    Levi, Aaron; Shaked, Danielle; Tadin, Duje; Huxlin, Krystel R.

    2015-01-01

    Many studies have shown that training and testing conditions modulate specificity of visual learning to trained stimuli and tasks. In visually impaired populations, generalizability of visual learning to untrained stimuli/tasks is almost always reported, with contrast sensitivity (CS) featuring prominently among these collaterally-improved functions. To understand factors underlying this difference, we measured CS for direction and orientation discrimination in the visual periphery of three groups of visually-intact subjects. Group 1 trained on an orientation discrimination task with static Gabors whose luminance contrast was decreased as performance improved. Group 2 trained on a global direction discrimination task using high-contrast random dot stimuli previously used to recover motion perception in cortically blind patients. Group 3 underwent no training. Both forms of training improved CS with some degree of specificity for basic attributes of the trained stimulus/task. Group 1's largest enhancement was in CS around the trained spatial/temporal frequencies; similarly, Group 2's largest improvements occurred in CS for discriminating moving and flickering stimuli. Group 3 saw no significant CS changes. These results indicate that CS improvements may be a natural consequence of multiple forms of visual training in visually intact humans, albeit with some specificity to the trained visual domain(s). PMID:26305736

  11. Effects of iodinated contrast agent, xylocaine and gadolinium concentration on the signal emitted in magnetic resonance arthrography: a samples study*

    PubMed Central

    da Silva, Yvana Lopes Pinheiro; Costa, Rita Zanlorensi Visneck; Pinho, Kátia Elisa Prus; Ferreira, Ricardo Rabello; Schuindt, Sueliton Miyamoto

    2015-01-01

    Objective To investigate the effects of dilution of paramagnetic contrast agent with iodinated contrast and xylocaine on the signal intensity during magnetic resonance arthrography, and to improve the paramagnetic contrast agent concentration utilized in this imaging modality. Materials and Methods Samples specially prepared for the study with three different concentrations of paramagnetic contrast agent diluted in saline, iodinated contrast agent and xylocaine were imaged with fast spin echo T1-weighted sequences with fat saturation. The samples were placed into flasks and graphical analysis of the signal intensity was performed as a function of the paramagnetic contrast concentration. Results As compared with samples of equal concentrations diluted only with saline, the authors have observed an average signal intensity decrease of 20.67% for iodinated contrast agent, and of 28.34% for xylocaine. However, the increased gadolinium concentration in the samples caused decrease in signal intensity with all the dilutions. Conclusion Minimizing the use of iodinated contrast media and xylocaine and/or the use of a gadolinium concentration of 2.5 mmol/L diluted in saline will improve the sensitivity of magnetic resonance arthrography. PMID:25987746

  12. Association of visual sensory function and higher order visual processing skills with incident driving cessation

    PubMed Central

    Huisingh, Carrie; McGwin, Gerald; Owsley, Cynthia

    2017-01-01

    Background Many studies on vision and driving cessation have relied on measures of sensory function, which are insensitive to the higher order cognitive aspects of visual processing. The purpose of this study was to examine the association between traditional measures of visual sensory function and higher order visual processing skills with incident driving cessation in a population-based sample of older drivers. Methods Two thousand licensed drivers aged ≥70 were enrolled and followed-up for three years. Tests for central vision and visual processing were administered at baseline and included visual acuity, contrast sensitivity, sensitivity in the driving visual field, visual processing speed (Useful Field of View (UFOV) Subtest 2 and Trails B), and spatial ability measured by the Visual Closure Subtest of the Motor-free Visual Perception Test. Participants self-reported the month and year of driving cessation and provided a reason for cessation. Cox proportional hazards models were used to generate crude and adjusted hazard ratios with 95% confidence intervals between visual functioning characteristics and risk of driving cessation over a three-year period. Results During the study period, 164 participants stopped driving which corresponds to a cumulative incidence of 8.5%. Impaired contrast sensitivity, visual fields, visual processing speed (UFOVand Trails B), and spatial ability were significant risk factors for subsequent driving cessation after adjusting for age, gender, marital status, number of medical conditions, and miles driven. Visual acuity impairment was not associated with driving cessation. Medical problems (63%), specifically musculoskeletal and neurological problems, as well as vision problems (17%) were cited most frequently as the reason for driving cessation. Conclusion Assessment of cognitive and visual functioning can provide useful information about subsequent risk of driving cessation among older drivers. In addition, a variety of factors, not just vision, influenced the decision to stop driving and may be amenable to intervention. PMID:27353969

  13. What you can't feel won't hurt you: Evaluating haptic hardware using a haptic contrast sensitivity function.

    PubMed

    Salisbury, C M; Gillespie, R B; Tan, H Z; Barbagli, F; Salisbury, J K

    2011-01-01

    In this paper, we extend the concept of the contrast sensitivity function - used to evaluate video projectors - to the evaluation of haptic devices. We propose using human observers to determine if vibrations rendered using a given haptic device are accompanied by artifacts detectable to humans. This determination produces a performance measure that carries particular relevance to applications involving texture rendering. For cases in which a device produces detectable artifacts, we have developed a protocol that localizes deficiencies in device design and/or hardware implementation. In this paper, we present results from human vibration detection experiments carried out using three commercial haptic devices and one high performance voice coil motor. We found that all three commercial devices produced perceptible artifacts when rendering vibrations near human detection thresholds. Our protocol allowed us to pinpoint the deficiencies, however, and we were able to show that minor modifications to the haptic hardware were sufficient to make these devices well suited for rendering vibrations, and by extension, the vibratory components of textures. We generalize our findings to provide quantitative design guidelines that ensure the ability of haptic devices to proficiently render the vibratory components of textures.

  14. A 3D imaging system integrating photoacoustic and fluorescence orthogonal projections for anatomical, functional and molecular assessment of rodent models

    NASA Astrophysics Data System (ADS)

    Brecht, Hans P.; Ivanov, Vassili; Dumani, Diego S.; Emelianov, Stanislav Y.; Anastasio, Mark A.; Ermilov, Sergey A.

    2018-03-01

    We have developed a preclinical 3D imaging instrument integrating photoacoustic tomography and fluorescence (PAFT) addressing known deficiencies in sensitivity and spatial resolution of the individual imaging components. PAFT is designed for simultaneous acquisition of photoacoustic and fluorescence orthogonal projections at each rotational position of a biological object, enabling direct registration of the two imaging modalities. Orthogonal photoacoustic projections are utilized to reconstruct large (21 cm3 ) volumes showing vascularized anatomical structures and regions of induced optical contrast with spatial resolution exceeding 100 µm. The major advantage of orthogonal fluorescence projections is significant reduction of background noise associated with transmitted or backscattered photons. The fluorescence imaging component of PAFT is used to boost detection sensitivity by providing low-resolution spatial constraint for the fluorescent biomarkers. PAFT performance characteristics were assessed by imaging optical and fluorescent contrast agents in tissue mimicking phantoms and in vivo. The proposed PAFT technology will enable functional and molecular volumetric imaging using fluorescent biomarkers, nanoparticles, and other photosensitive constructs mapped with high fidelity over robust anatomical structures, such as skin, central and peripheral vasculature, and internal organs.

  15. Impaired temporal contrast sensitivity in dyslexics is specific to retain-and-compare paradigms.

    PubMed

    Ben-Yehudah, G; Sackett, E; Malchi-Ginzberg, L; Ahissar, M

    2001-07-01

    Developmental dyslexia is a specific reading disability that affects 5-10% of the population. Recent studies have suggested that dyslexics may experience a deficit in the visual magnocellular pathway. The most extensively studied prediction deriving from this hypothesis is impaired contrast sensitivity to transient, low-luminance stimuli at low spatial frequencies. However, the findings are inconsistent across studies and even seemingly contradictory. In the present study, we administered several different paradigms for assessing temporal contrast sensitivity, and found both impaired and normal contrast sensitivity within the same group of dyslexic participants. Under sequential presentation, in a temporal forced choice paradigm, dyslexics showed impaired sensitivity to both drifting and flickering gratings. However, under simultaneous presentation, with a spatial forced choice paradigm, dyslexics' sensitivity did not differ from that of the controls. Within each paradigm, dyslexics' sensitivity was poorer at higher temporal frequencies, consistent with the magnocellular hypothesis. These results suggest that a basic perceptual impairment in dyslexics may be their limited ability to retain-and-compare perceptual traces across brief intervals.

  16. Physiology of leptin: energy homeostasis, neuroendocrine function and metabolism

    PubMed Central

    Park, Hyeong-Kyu; Ahima, Rexford S.

    2014-01-01

    Leptin is secreted by adipose tissue and regulates energy homeostasis, neuroendocrine function, metabolism, immune function and other systems through its effects on the central nervous system and peripheral tissues. Leptin administration has been shown to restore metabolic and neuroendocrine abnormalities in individuals with leptin-deficient states, including hypothalamic amenorrhea and lipoatrophy. In contrast, obese individuals are resistant to leptin. Recombinant leptin is beneficial in patients with congenital leptin deficiency or generalized lipodystrophy. However, further research on molecular mediators of leptin resistance is needed for the development of targeted leptin sensitizing therapies for obesity and related metabolic diseases. PMID:25199978

  17. Lateral interactions and speed of information processing in highly functioning multiple sclerosis patients.

    PubMed

    Nagy, Helga; Bencsik, Krisztina; Rajda, Cecília; Benedek, Krisztina; Janáky, Márta; Beniczky, Sándor; Kéri, Szabolcs; Vécsei, László

    2007-06-01

    Visual impairment is a common feature of multiple sclerosis. The aim of this study was to investigate lateral interactions in the visual cortex of highly functioning patients with multiple sclerosis and to compare that with basic visual and neuropsychologic functions. Twenty-two young, visually unimpaired multiple sclerosis patients with minimal symptoms (Expanded Disability Status Scale <2) and 30 healthy controls subjects participated in the study. Lateral interactions were investigated with the flanker task, during which participants were asked to detect the orientation of a low-contrast Gabor patch (vertical or horizontal), flanked with 2 collinear or orthogonal Gabor patches. Stimulus exposure time was 40, 60, 80, and 100 ms. Digit span forward/backward, digit symbol, verbal fluency, and California Verbal Learning Test procedures were used for background neuropsychologic assessment. Results revealed that patients with multiple sclerosis showed intact visual contrast sensitivity and neuropsychologic functions, whereas orientation detection in the orthogonal condition was significantly impaired. At 40-ms exposure time, collinear flankers facilitated the orientation detection performance of the patients resulting in normal performance. In conclusion, the detection of briefly presented, low-contrast visual stimuli was selectively impaired in multiple sclerosis. Lateral interactions between target and flankers robustly facilitated target detection in the patient group.

  18. Survey of Experimental Results in High-Contrast Imaging for Future Exoplanet Missions

    NASA Technical Reports Server (NTRS)

    Lawson, P. R.; Belikov, R.; Cash, W.; Clampin, M.; Glassman, T.; Guyon, O.; Kasdin, N. J.; Kern, B. D.; Lyon, R.; Mawet, D.; hide

    2013-01-01

    We present and compare experimental results in high contrast imaging representing the state of the art in coronagraph and starshade technology. These experiments have been undertaken with the goal of demonstrating the capability of detecting Earth-like planets around nearby Sun-like stars. The contrast of an Earth seen in reflected light around a Sun-like star would be about 1.2 x 10(exp -10). Several of the current candidate technologies now yield raw contrasts of 1.0 x 10(exp -9) or better, and so should enable the detection of Earths, assuming a gain in sensitivity in post-processing of a factor of 10. We present results of coronagraph and starshade experiments conducted at visible and infrared wavelengths. Cross-sections of dark fields are directly compared as a function of field angle and bandwidth. The strength and differences of the techniques are compared.

  19. Maximizing Information From Routine Staging Computed Tomography in Functional Neuroendocrine Neoplasms: Are There Findings Indicating the Presence of Carcinoid Heart Disease?

    PubMed

    Baur, Alexander Daniel Jacques; Kunz, Florian; Schwenke, Carsten; Pschowski, René; Röpke, Torsten Kai; Pavel, Marianne; Denecke, Timm

    2016-01-01

    The aim of this study was to evaluate signs of right-sided heart dysfunction on staging computed tomography (CT) as indirect indicators of carcinoid heart disease. Patients with functionally active neuroendocrine neoplasm and different grades of tricuspid valve regurgitation (TR) were identified. Two readers independently reviewed contrast-enhanced staging CT performed within 90 days before or after echocardiography. Logistic regression and receiver operating analyses were used to asses the predictive value of right ventricle-left ventricle ratio (RV-LV ratio), ventricular septal bowing, retrograde contrast filling of the hepatic veins during contrast injection, and time to aortal enhancement greater than 100 Hounsfield units during bolus tracking for TR. Forty-four examinations were evaluated (11 with TR = 0, 16 with TR = 1, 9 with TR = 2, and 8 with TR = 3). Right ventricle-LV ratio was found to predict TR less than or equal to 1 versus TR greater than 1 (P = 0.0188) and TR less than or equal to 1 versus TR equals 2 (P = 0.0082). A prolonged time to aortal enhancement greater than 100 Hounsfield units during bolus tracking predicted TR less than or equal to 1 versus TR greater than 1 (P = 0.0077). Area under the curve for RV-LV ratio was 0.86 when differentiating TR less than or equal to 1 versus TR equals 2. With a cutoff of 1.07, sensitivity was 0.89, and specificity was 0.72. In patients with functionally active neuroendocrine neoplasm, an RV-LV ratio of more than 1.07 predicted TR with a relatively high sensitivity and moderate specificity and thus could serve as an indicator of subclinical carcinoid heart disease on routine staging CT.

  20. Visual Cortical Function in Very Low Birth Weight Infants without Retinal or Cerebral Pathology

    PubMed Central

    Hou, Chuan; Norcia, Anthony M.; Madan, Ashima; Tith, Solina; Agarwal, Rashi

    2011-01-01

    Purpose. Preterm infants are at high risk of visual and neural developmental deficits. However, the development of visual cortical function in preterm infants with no retinal or neurologic morbidity has not been well defined. To determine whether premature birth itself alters visual cortical function, swept parameter visual evoked potential (sVEP) responses of healthy preterm infants were compared with those of term infants. Methods. Fifty-two term infants and 58 very low birth weight (VLBW) infants without significant retinopathy of prematurity or neurologic morbidities were enrolled. Recruited VLBW infants were between 26 and 33 weeks of gestational age, with birth weights of less than 1500 g. Spatial frequency, contrast, and vernier offset sweep VEP tuning functions were measured at 5 to 7 months' corrected age. Acuity and contrast thresholds were derived by extrapolating the tuning functions to 0 amplitude. These thresholds and suprathreshold response amplitudes were compared between groups. Results. Preterm infants showed increased thresholds (indicating decreased sensitivity to visual stimuli) and reductions in amplitudes for all three measures. These changes in cortical responsiveness were larger in the <30 weeks ' gestational age subgroup than in the ≥30 weeks' gestational age subgroup. Conclusions. Preterm infants with VLBW had measurable and significant changes in cortical responsiveness that were correlated with gestational age. These results suggest that premature birth in the absence of identifiable retinal or neurologic abnormalities has a significant effect on visual cortical sensitivity at 5 to 7 months' of corrected age and that gestational age is an important factor in visual development. PMID:22025567

  1. An empirical comparison of a dynamic software testability metric to static cyclomatic complexity

    NASA Technical Reports Server (NTRS)

    Voas, Jeffrey M.; Miller, Keith W.; Payne, Jeffrey E.

    1993-01-01

    This paper compares the dynamic testability prediction technique termed 'sensitivity analysis' to the static testability technique termed cyclomatic complexity. The application that we chose in this empirical study is a CASE generated version of a B-737 autoland system. For the B-737 system we analyzed, we isolated those functions that we predict are more prone to hide errors during system/reliability testing. We also analyzed the code with several other well-known static metrics. This paper compares and contrasts the results of sensitivity analysis to the results of the static metrics.

  2. [Comparative analysis of visual function and the quality of life index with eyeglasses or a progressive contact lens].

    PubMed

    Sant'Anna, Neusa Vidal; Schor, Paulo; Lipener, César; Uras, Ricardo

    2006-01-01

    To compare the visual function and the answers to a questionnaire of quality of life of patients wearing a progressive contact lens or eyeglasses. The Focus Progressive contact lens had been fitted in 35 patients with far visual acuity with progressive-addition eyeglasses equal to zero (log MAR) and near J1 (Jaeger). The far and near visual acuities and the measurement of contrast sensitivity were compared when the patients were wearing the eyeglasses or the contact lens and the patients' results of the scores of the quality of life questionnaire (NEI VFQ-25) were analyzed statistically considering the type of ametropy and the age. The far and near visual acuities and the contrast sensitivity measurement were worse with the contact lens than with eyeglasses. The answers to the questionnaire did not differ when were comparing the same patients wearing eyeglasses or contact lens, no matter the type of ametropy. The myopic and the hyperopic subgroups had worse answers to the quality of life questionnaire when corrected with the contact lens than with eyeglasses, both with age equal to or less than their median. The visual function was worse with the contact lens. The type of ametropy did not influence the answers to the quality of life questionnaire considering the optical correction, but age did.

  3. Enhanced neural function in highly aberrated eyes following perceptual learning with adaptive optics.

    PubMed

    Sabesan, Ramkumar; Barbot, Antoine; Yoon, Geunyoung

    2017-03-01

    Highly aberrated keratoconic (KC) eyes do not elicit the expected visual advantage from customized optical corrections. This is attributed to the neural insensitivity arising from chronic visual experience with poor retinal image quality, dominated by low spatial frequencies. The goal of this study was to investigate if targeted perceptual learning with adaptive optics (AO) can stimulate neural plasticity in these highly aberrated eyes. The worse eye of 2 KC subjects was trained in a contrast threshold test under AO correction. Prior to training, tumbling 'E' visual acuity and contrast sensitivity at 4, 8, 12, 16, 20, 24 and 28 c/deg were measured in both the trained and untrained eyes of each subject with their routine prescription and with AO correction for a 6mm pupil. The high spatial frequency requiring 50% contrast for detection with AO correction was picked as the training frequency. Subjects were required to train on a contrast detection test with AO correction for 1h for 5 consecutive days. During each training session, threshold contrast measurement at the training frequency with AO was conducted. Pre-training measures were repeated after the 5 training sessions in both eyes (i.e., post-training). After training, contrast sensitivity under AO correction improved on average across spatial frequency by a factor of 1.91 (range: 1.77-2.04) and 1.75 (1.22-2.34) for the two subjects. This improvement in contrast sensitivity transferred to visual acuity with the two subjects improving by 1.5 and 1.3 lines respectively with AO following training. One of the two subjects denoted an interocular transfer of training and an improvement in performance with their routine prescription post-training. This training-induced visual benefit demonstrates the potential of AO as a tool for neural rehabilitation in patients with abnormal corneas. Moreover, it reveals a sufficient degree of neural plasticity in normally developed adults who have a long history of abnormal visual experience due to optical imperfections. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Protein Profiles Reveal Diverse Responsive Signaling Pathways in Kernels of Two Maize Inbred Lines with Contrasting Drought Sensitivity

    PubMed Central

    Yang, Liming; Jiang, Tingbo; Fountain, Jake C.; Scully, Brian T.; Lee, Robert D.; Kemerait, Robert C.; Chen, Sixue; Guo, Baozhu

    2014-01-01

    Drought stress is a major factor that contributes to disease susceptibility and yield loss in agricultural crops. To identify drought responsive proteins and explore metabolic pathways involved in maize tolerance to drought stress, two maize lines (B73 and Lo964) with contrasting drought sensitivity were examined. The treatments of drought and well water were applied at 14 days after pollination (DAP), and protein profiles were investigated in developing kernels (35 DAP) using iTRAQ (isobaric tags for relative and absolute quantitation). Proteomic analysis showed that 70 and 36 proteins were significantly altered in their expression under drought treatments in B73 and Lo964, respectively. The numbers and levels of differentially expressed proteins were generally higher in the sensitive genotype, B73, implying an increased sensitivity to drought given the function of the observed differentially expressed proteins, such as redox homeostasis, cell rescue/defense, hormone regulation and protein biosynthesis and degradation. Lo964 possessed a more stable status with fewer differentially expressed proteins. However, B73 seems to rapidly initiate signaling pathways in response to drought through adjusting diverse defense pathways. These changes in protein expression allow for the production of a drought stress-responsive network in maize kernels. PMID:25334062

  5. Design and performance evaluation of a new high energy parallel hole collimator for radioiodine planar imaging by gamma cameras: Monte Carlo simulation study.

    PubMed

    Moslemi, Vahid; Ashoor, Mansour

    2017-05-01

    In addition to the trade-off between resolution and sensitivity which is a common problem among all types of parallel hole collimators (PCs), obtained images by high energy PCs (HEPCs) suffer from hole-pattern artifact (HPA) due to further septa thickness. In this study, a new design on the collimator has been proposed to improve the trade-off between resolution and sensitivity and to eliminate the HPA. A novel PC, namely high energy extended PC (HEEPC), is proposed and is compared to HEPCs. In the new PC, trapezoidal denticles were added upon the septa in the detector side. The performance of the HEEPCs were evaluated and compared to that of HEPCs using a Monte Carlo-N-particle version5 (MCNP5) simulation. The point spread functions (PSF) of HEPCs and HEEPCs were obtained as well as the various parameters such as resolution, sensitivity, scattering, and penetration ratios, and the HPA of the collimators was assessed. Furthermore, a Picker phantom study was performed to examine the effects of the collimators on the quality of planar images. It was found that the HEEPC D with an identical resolution to that of HEPC C increased sensitivity by 34.7%, and it improved the trade-off between resolution and sensitivity as well as to eliminate the HPA. In the picker phantom study, the HEEPC D indicated the hot and cold lesions with the higher contrast, lower noise, and higher contrast to noise ratio (CNR). Since the HEEPCs modify the shaping of PSFs, they are able to improve the trade-off between the resolution and sensitivity; consequently, planar images can be achieved with higher contrast resolutions. Furthermore, because the HEEPC S reduce the HPA and produce images with a higher CNR, compared to HEPCs, the obtained images by HEEPCs have a higher quality, which can help physicians to provide better diagnosis.

  6. The role of sensory ocular dominance on through-focus visual performance in monovision presbyopia corrections

    PubMed Central

    Zheleznyak, Len; Alarcon, Aixa; Dieter, Kevin C.; Tadin, Duje; Yoon, Geunyoung

    2015-01-01

    Monovision presbyopia interventions exploit the binocular nature of the visual system by independently manipulating the optical properties of the two eyes. It is unclear, however, how individual variations in ocular dominance affect visual function in monovision corrections. Here, we examined the impact of sensory ocular dominance on visual performance in both traditional and modified monovision presbyopic corrections. We recently developed a binocular adaptive optics vision simulator to correct subjects' native aberrations and induce either modified monovision (1.5 D anisometropia, spherical aberration of +0.1 and −0.4 μm in distance and near eyes, respectively, over 4 mm pupils) or traditional monovision (1.5 D anisometropia). To quantify both the sign and the degree of ocular dominance, we utilized binocular rivalry to estimate stimulus contrast ratios that yield balanced dominance durations for the two eyes. Through-focus visual acuity and contrast sensitivity were measured under two conditions: (a) assigning dominant and nondominant eye to distance and near, respectively, and (b) vice versa. The results revealed that through-focus visual acuity was unaffected by ocular dominance. Contrast sensitivity, however, was significantly improved when the dominant eye coincided with superior optical quality. We hypothesize that a potential mechanism behind this observation is an interaction between ocular dominance and binocular contrast summation, and thus, assignment of the dominant eye to distance or near may be an important factor to optimize contrast threshold performance at different object distances in both modified and traditional monovision. PMID:26024464

  7. Comparative and developmental patterns of amphibious auditory function in salamanders.

    PubMed

    Zeyl, Jeffrey N; Johnston, Carol E

    2016-12-01

    Early amphibious tetrapods may have detected aquatic sound pressure using sound-induced lung vibrations, but their lack of tympanic middle ears would have restricted aerial sensitivity. Sharing these characteristics, salamanders could be models for the carryover of auditory function across an aquatic-terrestrial boundary without tympanic middle ears. We measured amphibious auditory evoked potential audiograms in five phylogenetically and ecologically distinct salamanders (Amphiuma means, Notophthalmus viridescens, Ambystoma talpoideum, Eurycea spp., and Plethodon glutinosus) and tested whether metamorphosis and terrestrial niche were linked to aerial sensitivity. Threshold differences between media varied between species. A. means' relative aerial sensitivity was greatest at 100 Hz and decreased with increasing frequency. In contrast, all other salamanders retained greater sensitivity up to 500 Hz, and in A. talpoideum and Eurycea, relative sensitivity at 500 Hz was higher than at 100 Hz. Aerial thresholds of terrestrial P. glutinosus above 200 Hz were similar to A. talpoideum and Eurycea, but lower than N. viridescens and A. means. Metamorphosis did not affect aerial sensitivity in N. viridescens or A. talpoideum. These results fail to support a hypothesis of terrestrial hearing specialization across ontogeny or phylogeny. We discuss methodological limitations to our amphibious comparisons and factors affecting variation in amphibious performance.

  8. Serum Neutrophil Gelatinase-Associated Lipocalin and Urinary Kidney Injury Molecule-1 as Potential Biomarkers of Subclinical Nephrotoxicity After Gadolinium-Based and Iodinated-Based Contrast Media Exposure in Pediatric Patients with Normal Kidney Function

    PubMed Central

    Spasojević-Dimitrijeva, Brankica; Kotur-Stevuljević, Jelena; Đukić, Milan; Paripović, Dušan; Miloševski-Lomić, Gordana; Spasojević-Kalimanovska, Vesna; Pavićević, Polina; Mitrović, Jadranka; Kostić, Mirjana

    2017-01-01

    Background New renal biomarkers such as neutrophil gelatinase-associated lipocalin (NGAL) and kidney injury molecule-1 (KIM-1) show promise in early diagnosis of contrast media induced acute kidney injury (CI-AKI). The purpose of our study was to compare the subclinical nephrotoxicity (a condition without changes in standard renal biomarkers) of gadolinium-based contrast media (Gd-DTPA, gadopentetate dimeglumine) and iodinated-based contrast media (iopromide) in pediatric patients with normal kidney function. Material/Methods The first group (n=58) of patients included in the study were undergoing angiography with iopromide, and the second group (n=65) were undergoing magnetic resonance (MR) angiography/urography with Gd-DTPA administration. The concentrations of NGAL and KIM-1 were measured four times in the urine (pre-contrast, then at four hours, 24 hours, and 48 hours after contrast administration), and serum NGAL was measured at 0 (baseline), 24 hours, and 48 hours after contrast exposure. Results After 24 hours, serum NGAL increase of ≥25% was noticed in 32.6% of the patients in the iopromide group and in 25.45% of the patients in the gadolinium group, with significantly higher average percent of this increase in first group (62.23% vs. 36.44%, p=0.002). In the Gd-DTPA group, we observed a statistically significant increase in urinary KIM-1 24 hours after the procedure. Normalized urinary KIM-1, 24 hours after contrast exposure, was a better predictive factor for CI-AKI than other biomarkers (AUC 0.757, cut off 214 pg/mg, sensitivity 83.3%, specificity 54.2%, p=0.035). Conclusions In children with normal renal function, exposure to iodinated-based and gadolinium-based media might lead to subclinical nephrotoxicity, which could be detected using serum NGAL and urinary KIM-1. PMID:28874655

  9. Assessment of contrast sensitivity by Spaeth Richman Contrast Sensitivity Test and Pelli Robson Chart Test in patients with varying severity of glaucoma.

    PubMed

    Thakur, Sahil; Ichhpujani, Parul; Kumar, Suresh; Kaur, Ravneet; Sood, Sunandan

    2018-05-14

    This study was designed to assess the efficacy, reliability and repeatability of SPARCS (Spaeth Richman Contrast Sensitivity Test) as compared to the conventional Pelli Robson Chart Test for the assessment of contrast sensitivity in patients with glaucoma. We evaluated 135 eyes of 135 patients who were age and sex matched into three groups (controls, disc suspects and glaucoma) of 45 patients each. The glaucoma subgroup was further divided into subgroups of mild, moderate and severe based on the visual field damage. There was a strong positive correlation between Pelli Robson scores and SPARCS scores (S = 0.807, P < 0.001). Intraclass correlation coefficient (ICC) for Pelli Robson Test was 0.952 and 0.988 for SPARCS. The coefficient of repeatability (COR) for mean SPARCS was 5.65%, while COR of Pelli Robson Test was 12.44%. SPARCS was found to have better repeatability than Pelli Robson Test based on COR values. Pelli Robson score had a sensitivity of 80% and a specificity of 65.6% for detecting glaucoma patients as compared to 84.4% and 70%, respectively, for SPARCS scores. SPARCS is a better alternative to conventional Pelli Robson Chart Test for assessment of contrast sensitivity in patients with glaucoma. Being independent of the effects of literacy and educational status, it offers a universal way to measure contrast sensitivity. It can also be reliably used in patients with varying severity of glaucoma.

  10. Use of subjective and objective criteria to categorise visual disability.

    PubMed

    Kajla, Garima; Rohatgi, Jolly; Dhaliwal, Upreet

    2014-04-01

    Visual disability is categorised using objective criteria. Subjective measures are not considered. To use subjective criteria along with objective ones to categorise visual disability. Ophthalmology out-patient department; teaching hospital; observational study. Consecutive persons aged >25 years, with vision <20/20 (in one or both eyes) due to chronic conditions, like cataract and refractive errors, were categorized into 11 groups of increasing disability; group-zero: normal range of vision, to group-X: no perception of light, bilaterally. Snellen's vision; binocular contrast sensitivity (Pelli-Robson chart); automated binocular visual field (Humphrey; Esterman test); and vision-related quality of life (Indian Visual Function Questionnaire-33; IND-VFQ33) were recorded. SPSS version-17; Kruskal-wallis test was used to compare contrast sensitivity and visual fields across groups, and Mann-Whitney U test for pair-wise comparison (Bonferroni adjustment; P < 0.01). One-way ANOVA compared quality of life data across groups; for pairwise significance, Dunnett T3 test was applied. In 226 patients, contrast sensitivity and visual fields were comparable for differing disability grades except when disability was severe (P < 0.001), or moderately severe (P < 0.01). Individual scales of IND-VFQ33 were also mostly comparable; however, global scores showed a distinct pattern, being different for some disability grades but comparable for groups III (78.51 ± 6.86) and IV (82.64 ± 5.80), and groups IV and V (77.23 ± 3.22); these were merged to generate group 345; similarly, global scores were comparable for adjacent groups V and VI (72.53 ± 6.77), VI and VII (74.46 ± 4.32), and VII and VIII (69.12 ± 5.97); these were merged to generate group 5678; thereafter, contrast sensitivity and global and individual IND-VFQ33 scores could differentiate between different grades of disability in the five new groups. Subjective criteria made it possible to objectively reclassify visual disability. Visual disability grades could be redefined to accommodate all from zero-100%.

  11. A cute and highly contrast-sensitive superposition eye - the diurnal owlfly Libelloides macaronius.

    PubMed

    Belušič, Gregor; Pirih, Primož; Stavenga, Doekele G

    2013-06-01

    The owlfly Libelloides macaronius (Insecta: Neuroptera) has large bipartite eyes of the superposition type. The spatial resolution and sensitivity of the photoreceptor array in the dorsofrontal eye part was studied with optical and electrophysiological methods. Using structured illumination microscopy, the interommatidial angle in the central part of the dorsofrontal eye was determined to be Δϕ=1.1 deg. Eye shine measurements with an epi-illumination microscope yielded an effective superposition pupil size of about 300 facets. Intracellular recordings confirmed that all photoreceptors were UV-receptors (λmax=350 nm). The average photoreceptor acceptance angle was 1.8 deg, with a minimum of 1.4 deg. The receptor dynamic range was two log units, and the Hill coefficient of the intensity-response function was n=1.2. The signal-to-noise ratio of the receptor potential was remarkably high and constant across the whole dynamic range (root mean square r.m.s. noise=0.5% Vmax). Quantum bumps could not be observed at any light intensity, indicating low voltage gain. Presumably, the combination of large aperture superposition optics feeding an achromatic array of relatively insensitive receptors with a steep intensity-response function creates a low-noise, high spatial acuity instrument. The sensitivity shift to the UV range reduces the clutter created by clouds within the sky image. These properties of the visual system are optimal for detecting small insect prey as contrasting spots against both clear and cloudy skies.

  12. Noise Enhanced Sensory Signal Processing

    DTIC Science & Technology

    2012-01-31

    Moreover, a contrast sensitivity function (CSF), as an object feature enhancer , was employed for further improving the segmentation performance, which...Digital mammography work appeared in ACM Tech News on Feb. 3, 2010. 8. Interactions/Transitions Invited talks: • P.K. Varshney, “Noise Enhanced ... mammography machines with regard to our work on image enhancement based on SR. • Lectures at Lockheed Martin in Syracuse and SRC that included discussion

  13. DNA Repair Modulates The Vulnerability of The Developing Brain to Alkylating Agents

    PubMed Central

    Kisby, G.E.; Olivas, A.; Park, T.; Churchwell, M.; Doerge, D.; Samson, L. D.; Gerson, S.L.; Turker, M.S.

    2009-01-01

    Neurons of the developing brain are especially vulnerable to environmental agents that damage DNA (i.e., genotoxicants), but the mechanism is poorly understood. The focus of the present study is to demonstrate that DNA damage plays a key role in disrupting neurodevelopment. To examine this hypothesis, we compared the cytotoxic and DNA damaging properties of the methylating agents methylazoxymethanol (MAM) and dimethyl sulfate (DMS) and the mono- and bifunctional alkylating agents chloroethylamine (CEA) and nitrogen mustard (HN2), in granule cell neurons derived from the cerebellum of neonatal wild type mice and three transgenic DNA repair strains. Wild type cerebellar neurons were significantly more sensitive to the alkylating agents DMS and HN2 than neuronal cultures treated with MAM or the half-mustard CEA. Parallel studies with neuronal cultures from mice deficient in alkylguanine DNA glycosylase (Aag-/-) or O6-methylguanine methyltransferase (Mgmt-/-), revealed significant differences in the sensitivity of neurons to all four genotoxicants. Mgmt-/- neurons were more sensitive to MAM and HN2 than the other genotoxicants and wild type neurons treated with either alkylating agent. In contrast, Aag-/- neurons were for the most part significantly less sensitive than wild type or Mgmt-/- neurons to MAM and HN2. Aag-/- neurons were also significantly less sensitive than wild type neurons treated with either DMS or CEA. Granule cell development and motor function were also more severely disturbed by MAM and HN2 in Mgmt-/- mice than in comparably treated wild type mice. In contrast, cerebellar development and motor function were well preserved in MAM treated Aag-/- or MGMT overexpressing (MgmtTg+) mice, even as compared with wild type mice suggesting that AAG protein increases MAM toxicity, whereas MGMT protein decreases toxicity. Surprisingly, neuronal development and motor function were severely disturbed in MgmtTg+ mice treated with HN2. Collectively, these in vitro and in vivo studies demonstrate that the type of DNA lesion and the efficiency of DNA repair are two important factors that determine the vulnerability of the developing brain to long-term injury by a genotoxicant. PMID:19162564

  14. Evaluation of transcatheter arterial embolization therapy on hepatocellular carcinomas using contrast-enhanced harmonic power Doppler sonography: comparison with CT, power Doppler sonography, and dynamic MRI.

    PubMed

    Shima, Toshihide; Mizuno, Masayuki; Otsuji, Hideaki; Mizuno, Chiemi; Obata, Hirozumi; Park, Hyohun; Nakajo, Shinobu; Okanoue, Takeshi

    2005-09-01

    The aim of this study was to assess and compare the sensitivity of power Doppler sonography, contrast-enhanced sonography, plain computed tomography (CT), and dynamic magnetic resonance imaging (MRI) for detecting hepatocellular carcinoma (HCC) nodules incompletely treated with transcatheter arterial embolization (TAE). A total of 63 unresectable HCC nodules were examined in this study. The HCCs were treated with TAE. All patients underwent plain CT, power Doppler sonography, contrast-enhanced harmonic power Doppler sonography, and dynamic MRI 1 week after TAE. The sensitivity of each modality to incompletely treated HCC nodules was compared. Detection of the residual viable HCC on angiography or tumor biopsy was regarded as the gold standard for the diagnosis of incomplete treatment. Twenty-four nodules (38%) were diagnosed as incompletely treated. The sensitivities of plain CT, power Doppler sonography, contrast-enhanced harmonic power Doppler sonography, and dynamic MRI to these incompletely treated nodules were 42% (10/24), 46% (11/24), 88% (21/24), and 79% (19/24), respectively. Eighty percent (19 nodules) of the 24 incompletely treated nodules were located within a depth of less than 8 cm. The sensitivities of plain CT, power Doppler sonography, contrast-enhanced harmonic power Doppler sonography, and dynamic MRI to these superficial incompletely treated nodules were 37% (7/19), 53% (10/19), 100% (19/19), and 74% (14/19), respectively. In contrast, the sensitivities of each modality to deeply located nodules were 60% (3/5), 20% (1/5), 40% (2/5), and 100% (5/5), respectively. Plain CT and power Doppler sonography had a low sensitivity to HCC nodules incompletely treated with TAE. Except for those that were deeply located, contrast-enhanced harmonic sonography showed the highest sensitivity in detecting incompletely treated HCC nodules.

  15. Postoperative ocular higher-order aberrations and contrast sensitivity: femtosecond lenticule extraction versus pseudo small-incision lenticule extraction.

    PubMed

    Tan, Deborah K L; Tay, Wan Ting; Chan, Cordelia; Tan, Donald T H; Mehta, Jodhbir S

    2015-03-01

    To evaluate and compare changes in contrast sensitivity and ocular higher-order aberrations (HOAs) after femtosecond lenticule extraction (FLEx) and pseudo small-incision lenticule extraction (SMILE). Singapore National Eye Centre, Singapore. Retrospective case series. Patients had femtosecond lenticule extraction (Group 1) or pseudo small-incision lenticule extraction (Group 2) between March 2010 and December 2011. The main outcome measures were manifest refraction, HOAs, and contrast sensitivity 1, 3, 6, and 12 months postoperatively. Fifty-two consecutive patients (102 eyes) were recruited, 21 patients (42 eyes) in Group 1 and the 31 patients (60 eyes) in Group 2. The uncorrected and corrected distance visual acuities were significantly better in Group 2 than in Group 1 at 12 months (P = .032). There was no significant increase in 3rd- or 4th-order aberrations at 1 year and no significant difference between the 2 groups preoperatively or postoperatively. At 1 year, there was a significant increase in mesopic contrast sensitivity in Group 2 at 1.5 cycles per degree (cpd) (P = .008) that was not found in Group 1, and photopic contrast sensitivity at 6.0 cpd was higher in Group 2 (P = .027). These results indicate that refractive lenticule extraction is safe and effective with no significant induction of HOAs or deterioration in contrast sensitivity at 1 year. Induction of HOAs was not significantly different between both variants of refractive lenticule extraction. However, there was significant improvement in photopic contrast sensitivity after pseudo small-incision lenticule extraction, which persisted through 1 year. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  16. Transpalpebral electrotherapy for dry age-related macular degeneration (AMD): an exploratory trial.

    PubMed

    Anastassiou, Gerasimos; Schneegans, Anna-Lena; Selbach, Michael; Kremmer, Stephan

    2013-01-01

    To evaluate the effect of transpalpebral electrotherapy on patients with dry age-related macular degeneration (AMD). 22 patients were randomized in two groups to either receive therapy (n = 12) or placebo (n = 10). There was no statistically significant difference for age and initial visual acuity (VA) between the two groups (p = 0.6; ANOVA). Treatment was performed on 5 consecutive days. On each day two sessions were applied. Every session included 8 spots (40 sec/spot) around the eye globe. The current applied (changing frequency 5-80 Hz) varied individually between 150 and 220 μA. Patients were examined before treatment, at the end of the 5-day treatment period, after 4 weeks and at 6 months. Examinations included a standardized VA testing, using ETDRS letters, contrast sensitivity, macular sensitivity and fixation stability using microperimetry and measurements with SD-OCT. At the end of week 1, mean VA improved markedly (p = 0.001; T test), with 7 out of 12 patients showing an improvement of more than 5 letters. After 4 weeks, there was an improvement of more than 10 letters in 3 patients (mean + 5.7 letters; p = 0.001; T test) whereas at 6 months a loss of 1.6 letters was observed. Only 4 (33%) of our patients did not show any improvement at all. Contrast sensitivity displayed a similar pattern. Within one week after treatment, there was a rapid improvement (+4.4 optotypes; p = 0.006; T test). After 6 months, contrast sensitivity declined again (+1.5 optotypes; p = 0.2; T test). Compared to the placebo group changes on VA failed statistical significance (p = 0.1 at 4 week; T test) whereas changes on contrast sensitivity were statistically significant (p = 0.01 at week 4; T test). No adverse events were seen or reported during the study period. To the best of our knowledge, this is the first report of a transpalpebral electrostimulation in patients with dry AMD that demonstrates a temporary increase in visual function in some of these patients; results that seem to justify further research on this potential treatment option for dry AMD.

  17. Involvement of aquaporin NIP1;1 in the contrasting tolerance response to root hypoxia in Prunus rootstocks.

    PubMed

    Mateluna, Patricio; Salvatierra, Ariel; Solis, Simón; Nuñez, Gabriel; Pimentel, Paula

    2018-05-12

    Prunus species have been classified as moderately sensitive to root hypoxia, but with a certain intrageneric tolerance degree to oxygen deficiency. Previously, RNA-seq analysis described the transcriptomic reconfiguration of two Prunus rootstocks contrasting to root hypoxia, which included the shift from aerobic to anaerobic metabolism. Here, we studied the relationship between lactate accumulation and the functionality of an aquaporin differentially expressed in 'Mariana 2624', a plum-based (Prunus cerasifera x Prunus munsoniana) rootstock tolerant to root hypoxia stress, and 'Mazzard F12/1', a cherry-based (Prunus avium) rootstock sensitive to root hypoxia stress. In the root hypoxia-sensitive rootstock, higher levels of lactate and LDH1 gene expression were found in roots exposed to oxygen deprivation. Concomitantly, we detected an increase in the mRNA abundance of Prunus spp. NIP1;1, a putative lactic acid transporter. Intriguingly, the high expression of PruavNIP1;1 is not linked to a lower lactic acid content in the roots of 'Mazzard F12/1'. To study this phenomenon, we calculated the force required for the transit of a lactic acid molecule through Prunus spp. NIP1;1 channels. Comparing the calculated forces, we identified steric hindrances in PruavNIP1;1 given by the residues Phe107 and Trp88 in the NPA region and ar/R filter, respectively. The functionality of both channels was corroborated by the restoration of the lactic acid transport and the differential lactic acid sensitive-phenotypes of the yeast strain Δjen1 complemented with PruavNIP1;1 and PrucxmNIP1;1. Our findings provide new insights into the mechanisms involved in determining hypoxia tolerance between closely related species, such as plum and cherry. Copyright © 2018 Elsevier GmbH. All rights reserved.

  18. The effect of transcranial direct current stimulation on contrast sensitivity and visual evoked potential amplitude in adults with amblyopia

    PubMed Central

    Ding, Zhaofeng; Li, Jinrong; Spiegel, Daniel P.; Chen, Zidong; Chan, Lily; Luo, Guangwei; Yuan, Junpeng; Deng, Daming; Yu, Minbin; Thompson, Benjamin

    2016-01-01

    Amblyopia is a neurodevelopmental disorder of vision that occurs when the visual cortex receives decorrelated inputs from the two eyes during an early critical period of development. Amblyopic eyes are subject to suppression from the fellow eye, generate weaker visual evoked potentials (VEPs) than fellow eyes and have multiple visual deficits including impairments in visual acuity and contrast sensitivity. Primate models and human psychophysics indicate that stronger suppression is associated with greater deficits in amblyopic eye contrast sensitivity and visual acuity. We tested whether transcranial direct current stimulation (tDCS) of the visual cortex would modulate VEP amplitude and contrast sensitivity in adults with amblyopia. tDCS can transiently alter cortical excitability and may influence suppressive neural interactions. Twenty-one patients with amblyopia and twenty-seven controls completed separate sessions of anodal (a-), cathodal (c-) and sham (s-) visual cortex tDCS. A-tDCS transiently and significantly increased VEP amplitudes for amblyopic, fellow and control eyes and contrast sensitivity for amblyopic and control eyes. C-tDCS decreased VEP amplitude and contrast sensitivity and s-tDCS had no effect. These results suggest that tDCS can modulate visual cortex responses to information from adult amblyopic eyes and provide a foundation for future clinical studies of tDCS in adults with amblyopia. PMID:26763954

  19. The effect of transcranial direct current stimulation on contrast sensitivity and visual evoked potential amplitude in adults with amblyopia.

    PubMed

    Ding, Zhaofeng; Li, Jinrong; Spiegel, Daniel P; Chen, Zidong; Chan, Lily; Luo, Guangwei; Yuan, Junpeng; Deng, Daming; Yu, Minbin; Thompson, Benjamin

    2016-01-14

    Amblyopia is a neurodevelopmental disorder of vision that occurs when the visual cortex receives decorrelated inputs from the two eyes during an early critical period of development. Amblyopic eyes are subject to suppression from the fellow eye, generate weaker visual evoked potentials (VEPs) than fellow eyes and have multiple visual deficits including impairments in visual acuity and contrast sensitivity. Primate models and human psychophysics indicate that stronger suppression is associated with greater deficits in amblyopic eye contrast sensitivity and visual acuity. We tested whether transcranial direct current stimulation (tDCS) of the visual cortex would modulate VEP amplitude and contrast sensitivity in adults with amblyopia. tDCS can transiently alter cortical excitability and may influence suppressive neural interactions. Twenty-one patients with amblyopia and twenty-seven controls completed separate sessions of anodal (a-), cathodal (c-) and sham (s-) visual cortex tDCS. A-tDCS transiently and significantly increased VEP amplitudes for amblyopic, fellow and control eyes and contrast sensitivity for amblyopic and control eyes. C-tDCS decreased VEP amplitude and contrast sensitivity and s-tDCS had no effect. These results suggest that tDCS can modulate visual cortex responses to information from adult amblyopic eyes and provide a foundation for future clinical studies of tDCS in adults with amblyopia.

  20. The use of intrathecal analgesia and contrast radiography as preoperative diagnostic methods for digital flexor tendon sheath pathology.

    PubMed

    Fiske-Jackson, A R; Barker, W H J; Eliashar, E; Foy, K; Smith, R K W

    2013-01-01

    The sensitivity of ultrasonography for the diagnosis of manica flexoria (MF) tears within the digital flexor tendon sheath (DFTS) is lower than for diagnosis of marginal tears of the deep digital flexor tendon (DDFT). Additional diagnostic tools would assist in appropriate decision making for either conservative or surgical management. To evaluate the improvement in lameness of horses with MF or DDFT tears following intrathecal analgesia and to assess the sensitivity and specificity of contrast radiography for the diagnosis of these tears. The case records of horses presented to a referral clinic over a 7-year period that underwent intrathecal diagnostic analgesia, or intrathecal analgesia and contrast radiography, of the DFTS with subsequent tenoscopy were examined. Fifty-three limbs had intrathecal diagnostic analgesia performed and 23 contrast tenograms were assessed in horses undergoing DFTS tenoscopy. Horses with DDFT tears were significantly more likely to respond positively to intrathecal diagnostic analgesia than those with MF tears (P = 0.02). Using contrast radiography, tears of the MF were predicted with an overall sensitivity of 96% and specificity of 80%; marginal tears of the DDFT were predicted with an overall sensitivity of 57% and specificity of 84%. The results of intrathecal analgesia of the DFTS in combination with contrast radiography have a high sensitivity for predicting MF tears. The sensitivity of contrast radiography for predicting tears of the DDFT is lower but the specificity remains high. Contrast radiography performed at the same time as intrathecal analgesia provides useful information regarding the presence of MF tears and DDFT tears, which can assist in the decision of whether to manage the lameness conservatively or with tenoscopic evaluation. © 2012 EVJ Ltd.

  1. Spectral contrast-enhanced optical coherence tomography for improved detection of tumor microvasculature and functional imaging of lymphatic drainage

    NASA Astrophysics Data System (ADS)

    SoRelle, Elliott D.; Liba, Orly; Sen, Debasish; de la Zerda, Adam

    2017-03-01

    Optical Coherence Tomography (OCT) is well-suited to study in vivo dynamics of blood circulation and lymphatic flow because of the technique's combination of rapid image acquisition, micron spatial resolution, and penetration depth in turbid tissues. However, OCT has been historically constrained by a dearth of contrast agents that are readily distinguished from the strong scattering intrinsic to biological tissues. In this study, we demonstrate large gold nanorods (LGNRs) as optimized contrast agents for OCT. LGNRs produce 32-fold greater backscattering than GNRs previously tested for contrast-enhanced OCT. Furthermore, LGNRs exhibit 110-fold stronger spectral signal than conventional GNRs when coupled with custom spectral detection algorithms. This signal enhancement enables picomolar OCT detection sensitivity in vivo and single-particle detection against optically-clear backgrounds. Moreover, the ability to synthesize LGNRs with tunable spectral peaks provides a viable platform for multiplexed imaging studies. To explore the advantages of LGNRs as OCT contrast agents, we implemented them for noninvasive 3D imaging of tumor blood supply and active lymphatic drainage in mice. Spectral detection of LGNRs enabled 100% improvement in imaging depth for detecting microvasculature (vessels 20 μm in diameter) in U87MG glioblastoma xenografts in mice pinnae. We also demonstrated our approach's ability to map the spatial dependence of lymph drainage and flow directionality within lymphatic capillaries. Using LGNRs with distinct spectra, we further identified the functional states of individual lymphatic valves in vivo. Thus, this approach provides a powerful new platform for functional imaging that may be extended for future molecular imaging studies with OCT.

  2. Clustering effects on postprandial insulin secretion and sensitivity in response to meals with different fatty acid compositions.

    PubMed

    Bermudez, Beatriz; Ortega-Gomez, Almudena; Varela, Lourdes M; Villar, Jose; Abia, Rocio; Muriana, Francisco J G; Lopez, Sergio

    2014-07-25

    Dietary fatty acids play a role in glucose homeostasis. The aim of this study was to assess the individual relationship between dietary saturated (SFA), monounsaturated (MUFA) and polyunsaturated (PUFA) fatty acids with postprandial β-cell function and insulin sensitivity in subjects with normal and high fasting triglycerides. We assessed postprandial β-cell function (by the insulinogenic index and the ratio of the insulin to glucose areas under the time-concentration curve) and insulin sensitivity (by the oral glucose and the minimal model insulin sensitivity indices) over four nonconsecutive, randomly assigned, high-fat meals containing a panel of SFA (palmitic and stearic acids), MUFA (palmitoleic and oleic acids) and PUFA (linoleic and α-linolenic acids) in 14 subjects with normal and in 14 subjects with high fasting triglycerides. The proportions of each fatty acid in the meals and the values for surrogate measures of postprandial β-cell function and insulin sensitivity were subjected to a Pearson correlation and hierarchical cluster analysis, which revealed two classes of dietary fatty acids for regulating postprandial glucose homeostasis. We successfully discriminated the adverse effects of SFA palmitic acid from the beneficial effects of MUFA oleic acid on postprandial β-cell function (r ≥ 0.84 for SFA palmitic acid and r ≥ -0.71 for MUFA oleic acid; P < 0.05) and insulin sensitivity (r ≥ -0.92 for SFA palmitic acid and r ≥ 0.89 for MUFA oleic acid; P < 0.001) both in subjects with normal and high fasting triglycerides. In conclusion, dietary MUFA oleic acid, in contrast to SFA palmitic acid, favours the tuning towards better postprandial glycaemic control in subjects with normal and high fasting triglycerides.

  3. Chromatic and achromatic monocular deprivation produce separable changes of eye dominance in adults.

    PubMed

    Zhou, Jiawei; Reynaud, Alexandre; Kim, Yeon Jin; Mullen, Kathy T; Hess, Robert F

    2017-11-29

    Temporarily depriving one eye of its input, in whole or in part, results in a transient shift in eye dominance in human adults, with the patched eye becoming stronger and the unpatched eye weaker. However, little is known about the role of colour contrast in these behavioural changes. Here, we first show that the changes in eye dominance and contrast sensitivity induced by monocular eye patching affect colour and achromatic contrast sensitivity equally. We next use dichoptic movies, customized and filtered to stimulate the two eyes differentially. We show that a strong imbalance in achromatic contrast between the eyes, with no colour content, also produces similar, unselective shifts in eye dominance for both colour and achromatic contrast sensitivity. Interestingly, if this achromatic imbalance is paired with similar colour contrast in both eyes, the shift in eye dominance is selective, affecting achromatic but not chromatic contrast sensitivity and revealing a dissociation in eye dominance for colour and achromatic image content. On the other hand, a strong imbalance in chromatic contrast between the eyes, with no achromatic content, produces small, unselective changes in eye dominance, but if paired with similar achromatic contrast in both eyes, no changes occur. We conclude that perceptual changes in eye dominance are strongly driven by interocular imbalances in achromatic contrast, with colour contrast having a significant counter balancing effect. In the short term, eyes can have different dominances for achromatic and chromatic contrast, suggesting separate pathways at the site of these neuroplastic changes. © 2017 The Author(s).

  4. Alveolar macrophages have a dual role in a rat model for trimellitic anhydride-induced occupational asthma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Valstar, Dingena L.; Schijf, Marcel A.; Nijkamp, Frans P.

    2006-02-15

    Occupational exposure to low molecular weight chemicals, like trimellitic anhydride (TMA), can result in occupational asthma. Alveolar macrophages (AMs) are among the first cells to encounter inhaled compounds. These cells can produce many different mediators that have a putative role in asthma. In this study, we examined the role of AMs in lung function and airway inflammation of rats exposed to TMA. Female Brown Norway rats were sensitized by dermal application of TMA or received vehicle alone on days 0 and 7. One day before challenge, rats received intratracheally either empty or clodronate-containing liposomes to deplete the lungs of AMs.more » On day 21, all rats were challenged by inhalation of TMA in air. Lung function parameters were measured before, during, within 1 h after, and 24 h after challenge. IgE levels and parameters of inflammation and tissue damage were assessed 24 h after challenge. Sensitization with TMA led to decreased lung function parameters during and within 1 h after challenge as compared to non-sensitized rats. AM depletion alleviated the TMA-induced drop in lung function parameters and induced a faster recovery compared to sham-depleted TMA-sensitized rats. It also decreased the levels of serum IgE 24 h after challenge, but did not affect the sensitization-dependent increase in lung lavage fluid IL-6 and tissue TNF-{alpha} levels. In contrast, AM depletion augmented the TMA-induced tissue damage and inflammation 24 h after challenge. AMs seem to have a dual role in this model for TMA-induced occupational asthma since they potentiate the immediate TMA-induced decrease in lung function but tended to dampen the TMA-induced inflammatory reaction 24 h later.« less

  5. Empirically Derived and Simulated Sensitivity of Vegetation to Climate Across Global Gradients of Temperature and Precipitation

    NASA Astrophysics Data System (ADS)

    Quetin, G. R.; Swann, A. L. S.

    2017-12-01

    Successfully predicting the state of vegetation in a novel environment is dependent on our process level understanding of the ecosystem and its interactions with the environment. We derive a global empirical map of the sensitivity of vegetation to climate using the response of satellite-observed greenness and leaf area to interannual variations in temperature and precipitation. Our analysis provides observations of ecosystem functioning; the vegetation interactions with the physical environment, across a wide range of climates and provide a functional constraint for hypotheses engendered in process-based models. We infer mechanisms constraining ecosystem functioning by contrasting how the observed and simulated sensitivity of vegetation to climate varies across climate space. Our analysis yields empirical evidence for multiple physical and biological mediators of the sensitivity of vegetation to climate as a systematic change across climate space. Our comparison of remote sensing-based vegetation sensitivity with modeled estimates provides evidence for which physiological mechanisms - photosynthetic efficiency, respiration, water supply, atmospheric water demand, and sunlight availability - dominate the ecosystem functioning in places with different climates. Earth system models are generally successful in reproducing the broad sign and shape of ecosystem functioning across climate space. However, this general agreement breaks down in hot wet climates where models simulate less leaf area during a warmer year, while observations show a mixed response but overall more leaf area during warmer years. In addition, simulated ecosystem interaction with temperature is generally larger and changes more rapidly across a gradient of temperature than is observed. We hypothesize that the amplified interaction and change are both due to a lack of adaptation and acclimation in simulations. This discrepancy with observations suggests that simulated responses of vegetation to global warming, and feedbacks between vegetation and climate, are too strong in the models.

  6. Physiology of leptin: energy homeostasis, neuroendocrine function and metabolism.

    PubMed

    Park, Hyeong-Kyu; Ahima, Rexford S

    2015-01-01

    Leptin is secreted by adipose tissue and regulates energy homeostasis, neuroendocrine function, metabolism, immune function and other systems through its effects on the central nervous system and peripheral tissues. Leptin administration has been shown to restore metabolic and neuroendocrine abnormalities in individuals with leptin-deficient states, including hypothalamic amenorrhea and lipoatrophy. In contrast, obese individuals are resistant to leptin. Recombinant leptin is beneficial in patients with congenital leptin deficiency or generalized lipodystrophy. However, further research on molecular mediators of leptin resistance is needed for the development of targeted leptin sensitizing therapies for obesity and related metabolic diseases. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. QUEST+: A general multidimensional Bayesian adaptive psychometric method.

    PubMed

    Watson, Andrew B

    2017-03-01

    QUEST+ is a Bayesian adaptive psychometric testing method that allows an arbitrary number of stimulus dimensions, psychometric function parameters, and trial outcomes. It is a generalization and extension of the original QUEST procedure and incorporates many subsequent developments in the area of parametric adaptive testing. With a single procedure, it is possible to implement a wide variety of experimental designs, including conventional threshold measurement; measurement of psychometric function parameters, such as slope and lapse; estimation of the contrast sensitivity function; measurement of increment threshold functions; measurement of noise-masking functions; Thurstone scale estimation using pair comparisons; and categorical ratings on linear and circular stimulus dimensions. QUEST+ provides a general method to accelerate data collection in many areas of cognitive and perceptual science.

  8. Do common mechanisms of adaptation mediate color discrimination and appearance? Contrast adaptation

    NASA Astrophysics Data System (ADS)

    Hillis, James M.; Brainard, David H.

    2007-08-01

    Are effects of background contrast on color appearance and sensitivity controlled by the same mechanism of adaptation? We examined the effects of background color contrast on color appearance and on color-difference sensitivity under well-matched conditions. We linked the data using Fechner's hypothesis that the rate of apparent stimulus change is proportional to sensitivity and examined a family of parametric models of adaptation. Our results show that both appearance and discrimination are consistent with the same mechanism of adaptation.

  9. Four Theorems on the Psychometric Function

    PubMed Central

    May, Keith A.; Solomon, Joshua A.

    2013-01-01

    In a 2-alternative forced-choice (2AFC) discrimination task, observers choose which of two stimuli has the higher value. The psychometric function for this task gives the probability of a correct response for a given stimulus difference, . This paper proves four theorems about the psychometric function. Assuming the observer applies a transducer and adds noise, Theorem 1 derives a convenient general expression for the psychometric function. Discrimination data are often fitted with a Weibull function. Theorem 2 proves that the Weibull “slope” parameter, , can be approximated by , where is the of the Weibull function that fits best to the cumulative noise distribution, and depends on the transducer. We derive general expressions for and , from which we derive expressions for specific cases. One case that follows naturally from our general analysis is Pelli's finding that, when , . We also consider two limiting cases. Theorem 3 proves that, as sensitivity improves, 2AFC performance will usually approach that for a linear transducer, whatever the actual transducer; we show that this does not apply at signal levels where the transducer gradient is zero, which explains why it does not apply to contrast detection. Theorem 4 proves that, when the exponent of a power-function transducer approaches zero, 2AFC performance approaches that of a logarithmic transducer. We show that the power-function exponents of 0.4–0.5 fitted to suprathreshold contrast discrimination data are close enough to zero for the fitted psychometric function to be practically indistinguishable from that of a log transducer. Finally, Weibull reflects the shape of the noise distribution, and we used our results to assess the recent claim that internal noise has higher kurtosis than a Gaussian. Our analysis of for contrast discrimination suggests that, if internal noise is stimulus-independent, it has lower kurtosis than a Gaussian. PMID:24124456

  10. Techniques for improving material fidelity and contrast consistency in secondary electron mode helium ion microscope (HIM) imaging

    NASA Astrophysics Data System (ADS)

    Thompson, William; Stern, Lewis; Ferranti, Dave; Huynh, Chuong; Scipioni, Larry; Notte, John; Sanford, Colin

    2010-06-01

    Recent helium ion microscope (HIM) imaging studies have shown the strong sensitivity of HIM induced secondary electron (SE) yields [1] to the sample physical and chemical properties and to its surface topography. This SE yield sensitivity is due to the low recoil energy of the HIM initiated electrons and their resulting short mean free path. Additionally, a material's SE escape probability is modulated by changes in the material's work function and surface potential. Due to the escape electrons' roughly 2eV mean energy and their nanometer range mean free path, HIM SE mode image contrast has significant material and surface sensitivity. The latest generation of HIM has a 0.35 nanometer resolution specification and is equipped with a plasma cleaning process to mitigate the effects of hydrocarbon contamination. However, for surfaces that may have native oxide chemistries influencing the secondary electron yield, a new process of low energy, shallow angle argon sputtering, was evaluated. The intent of this work was to study the effect of removing pre-existing native oxides and any in-situ deposited surface contaminants. We will introduce the sputter yield predictions of two established computer models and the sputter yield and sample modification forecasts of the molecular dynamics program, Kalypso. We will review the experimental technique applied to copper samples and show the copper grain contrast improvement that resulted when argon cleaned samples were imaged in HIM SE mode.

  11. Grating-assisted demodulation of interferometric optical sensors.

    PubMed

    Yu, Bing; Wang, Anbo

    2003-12-01

    Accurate and dynamic control of the operating point of an interferometric optical sensor to produce the highest sensitivity is crucial in the demodulation of interferometric optical sensors to compensate for manufacturing errors and environmental perturbations. A grating-assisted operating-point tuning system has been designed that uses a diffraction grating and feedback control, functions as a tunable-bandpass optical filter, and can be used as an effective demodulation subsystem in sensor systems based on optical interferometers that use broadband light sources. This demodulation method has no signal-detection bandwidth limit, a high tuning speed, a large tunable range, increased interference fringe contrast, and the potential for absolute optical-path-difference measurement. The achieved 40-nm tuning range, which is limited by the available source spectrum width, 400-nm/s tuning speed, and a step resolution of 0.4 nm, is sufficient for most practical measurements. A significant improvement in signal-to-noise ratio in a fiber Fabry-Perot acoustic-wave sensor system proved that the expected fringe contrast and sensitivity increase.

  12. Encoding of luminance and contrast by linear and nonlinear synapses in the retina.

    PubMed

    Odermatt, Benjamin; Nikolaev, Anton; Lagnado, Leon

    2012-02-23

    Understanding how neural circuits transmit information is technically challenging because the neural code is contained in the activity of large numbers of neurons and synapses. Here, we use genetically encoded reporters to image synaptic transmission across a population of sensory neurons-bipolar cells in the retina of live zebrafish. We demonstrate that the luminance sensitivities of these synapses varies over 10(4) with a log-normal distribution. About half the synapses made by ON and OFF cells alter their polarity of transmission as a function of luminance to generate a triphasic tuning curve with distinct maxima and minima. These nonlinear synapses signal temporal contrast with greater sensitivity than linear ones. Triphasic tuning curves increase the dynamic range over which bipolar cells signal light and improve the efficiency with which luminance information is transmitted. The most efficient synapses signaled luminance using just 1 synaptic vesicle per second per distinguishable gray level. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Arrestin 1 and Cone Arrestin 4 Have Unique Roles in Visual Function in an All-Cone Mouse Retina.

    PubMed

    Deming, Janise D; Pak, Joseph S; Shin, Jung-A; Brown, Bruce M; Kim, Moon K; Aung, Moe H; Lee, Eun-Jin; Pardue, Machelle T; Craft, Cheryl Mae

    2015-12-01

    Previous studies discovered cone phototransduction shutoff occurs normally for Arr1-/- and Arr4-/-; however, it is defective when both visual arrestins are simultaneously not expressed (Arr1-/-Arr4-/-). We investigated the roles of visual arrestins in an all-cone retina (Nrl-/-) since each arrestin has differential effects on visual function, including ARR1 for normal light adaptation, and ARR4 for normal contrast sensitivity and visual acuity. We examined Nrl-/-, Nrl-/-Arr1-/-, Nrl-/-Arr4-/-, and Nrl-/-Arr1-/-Arr4-/- mice with photopic electroretinography (ERG) to assess light adaptation and retinal responses, immunoblot and immunohistochemical localization analysis to measure retinal expression levels of M- and S-opsin, and optokinetic tracking (OKT) to measure the visual acuity and contrast sensitivity. Study results indicated that Nrl-/- and Nrl-/-Arr4-/- mice light adapted normally, while Nrl-/-Arr1-/- and Nrl-/-Arr1-/-Arr4-/- mice did not. Photopic ERG a-wave, b-wave, and flicker amplitudes followed a general pattern in which Nrl-/-Arr4-/- amplitudes were higher than the amplitudes of Nrl-/-, while the amplitudes of Nrl-/-Arr1-/- and Nrl-/-Arr1-/-Arr4-/- were lower. All three visual arrestin knockouts had faster implicit times than Nrl-/- mice. M-opsin expression is lower when ARR1 is not expressed, while S-opsin expression is lower when ARR4 is not expressed. Although M-opsin expression is mislocalized throughout the photoreceptor cells, S-opsin is confined to the outer segments in all genotypes. Contrast sensitivity is decreased when ARR4 is not expressed, while visual acuity was normal except in Nrl-/-Arr1-/-Arr4-/-. Based on the opposite visual phenotypes in an all-cone retina in the Nrl-/-Arr1-/- and Nrl-/-Arr4-/- mice, we conclude that ARR1 and ARR4 perform unique modulatory roles in cone photoreceptors.

  14. Simplifying the assessment of coronary artery stenosis by enhancing instantaneous wave free ratio.

    PubMed

    Spagnoli, Vincent; Picard, Fabien; Tadros, Victor-Xavier; Cournoyer, Daniel; Doucet, Serge; Tanguay, Jean François; Gosselin, Gilbert; de Guise, Pierre; Gallo, Richard

    2018-04-01

    Instantaneous wave free ratio (iFR) does not require adenosine, but has a relatively wide intermediate range where functional assessment remains inconclusive. In this pilot study, we sought to enhance iFR through with the use of intracoronary (IC) saline (iFRs) and contrast media (iFRc) and determine whether these techniques correlated well with fractional flow reserve (FFR). Patients with coronary artery stenosis (CAS) associated with an iFR in the intermediate zone (≥0.86 and ≤0.93) were prospectively assessed with resting distal coronary pressure/aorta pressure (Pd/Pa), iFR, iFRs, iFRc and FFR. A total of 40 coronary lesions were studied (40 patients). Pearson correlation coefficients for FFR and iFR, FFR and iFRs, FFR and iFRc were respectively: 0.57 (P=0.0002), 0.80 (P<0.0001) and 0.77 (P<0.0001). Receiver-operating characteristic (ROC) curve analysis showed similar area under the curve (AUC) of iFRs and iFR [0.90 (95% CI: 0.76-1) vs. 0.89 (95% CI: 0.79-0.99), P=0.89]. Youden's index established cut-off values of ≤0.90 for iFR (sensitivity =91%, specificity =74%) and ≤0.78 for iFRs (sensitivity =73%, specificity =100%). In contrast, the AUC of iFRc was superior to the AUC of iFR [0.99 (95% CI: 0.98-1), P=0.049]. iFRc showed excellent accuracy and established cut-off values of ≤0.81 in predicting an FFR value of ≤0.80 (sensitivity =100%, specificity =93%). When iFR is in the intermediate zone, functional assessment of CAS by iFR is enhanced with the use of contrast media but not saline. This pilot study could be hypothesis generating for further study to enhance iFR specificity and sensibility.

  15. Simplifying the assessment of coronary artery stenosis by enhancing instantaneous wave free ratio

    PubMed Central

    Spagnoli, Vincent; Picard, Fabien; Tadros, Victor-Xavier; Cournoyer, Daniel; Doucet, Serge; Tanguay, Jean François; Gosselin, Gilbert; de Guise, Pierre

    2018-01-01

    Background Instantaneous wave free ratio (iFR) does not require adenosine, but has a relatively wide intermediate range where functional assessment remains inconclusive. In this pilot study, we sought to enhance iFR through with the use of intracoronary (IC) saline (iFRs) and contrast media (iFRc) and determine whether these techniques correlated well with fractional flow reserve (FFR). Methods Patients with coronary artery stenosis (CAS) associated with an iFR in the intermediate zone (≥0.86 and ≤0.93) were prospectively assessed with resting distal coronary pressure/aorta pressure (Pd/Pa), iFR, iFRs, iFRc and FFR. Results A total of 40 coronary lesions were studied (40 patients). Pearson correlation coefficients for FFR and iFR, FFR and iFRs, FFR and iFRc were respectively: 0.57 (P=0.0002), 0.80 (P<0.0001) and 0.77 (P<0.0001). Receiver-operating characteristic (ROC) curve analysis showed similar area under the curve (AUC) of iFRs and iFR [0.90 (95% CI: 0.76–1) vs. 0.89 (95% CI: 0.79–0.99), P=0.89]. Youden’s index established cut-off values of ≤0.90 for iFR (sensitivity =91%, specificity =74%) and ≤0.78 for iFRs (sensitivity =73%, specificity =100%). In contrast, the AUC of iFRc was superior to the AUC of iFR [0.99 (95% CI: 0.98–1), P=0.049]. iFRc showed excellent accuracy and established cut-off values of ≤0.81 in predicting an FFR value of ≤0.80 (sensitivity =100%, specificity =93%). Conclusions When iFR is in the intermediate zone, functional assessment of CAS by iFR is enhanced with the use of contrast media but not saline. This pilot study could be hypothesis generating for further study to enhance iFR specificity and sensibility. PMID:29850406

  16. Special tinted contact lens on colour-defects.

    PubMed

    Mutilab, H A; Sharanjeet-Kaur; Keu, L K; Choo, P F

    2012-01-01

    The objective of this study was to determine the visual function of colour-deficient subjects when wearing special red tint contact lenses. A total of 17 subjects with congenital colour vision deficiency (14 deutans and 3 protans), voluntarily participated in this study. The average age for the subjects was 23.00 ± 4.06 years old. Visual functions tested were visual acuity (LogMAR), contrast sensitivity (FACT Chart) and stereopsis (TNO and Howard Dolman tests). Two types of special red tint lenses were used in this study; Type I (light red) and Type II (dark red). The protans and deutans showed no significant changes in visual acuity and contrast sensitivity when wearing either type of contact lens. Stereopsis testing using the Horward-Dolman test gave no significant changes but significant differences were seen using the TNO test. Stereopsis using the TNO test was significantly poorer with the red tinted contact lenses compared to without for both protons and deutans. Testing binocularly with Ishihara plates showed that 88% (n=15) of patients passed the test with Type I and Type II contact lenses. When D15 test was done, 3 patients (17.6%) were 'normal' when using the Type I contact lenses and 2 patients (11.8%) were 'normal' when using the Type II contact lenses. However, with FM100Hue test, most patients showed deutan responses. Total error scores (TES) were found to be higher with Type I and Type II contact lenses compared to without. The Type I and II special tinted contact lens used in this study did not cause a reduction of visual acuity and contrast sensitivity for the colour defects. Stereopsis was also not reduced with the Type I and Type II contact lenses for the colour defects except when tested with the TNO test. Colour vision defects became difficult to detect using the Ishihara plates but FM100Hue test did not show any improvement with the Type I and Type II contact lenses.

  17. Peripheral Vision of Youths with Low Vision: Motion Perception, Crowding, and Visual Search

    PubMed Central

    Tadin, Duje; Nyquist, Jeffrey B.; Lusk, Kelly E.; Corn, Anne L.; Lappin, Joseph S.

    2012-01-01

    Purpose. Effects of low vision on peripheral visual function are poorly understood, especially in children whose visual skills are still developing. The aim of this study was to measure both central and peripheral visual functions in youths with typical and low vision. Of specific interest was the extent to which measures of foveal function predict performance of peripheral tasks. Methods. We assessed central and peripheral visual functions in youths with typical vision (n = 7, ages 10–17) and low vision (n = 24, ages 9–18). Experimental measures used both static and moving stimuli and included visual crowding, visual search, motion acuity, motion direction discrimination, and multitarget motion comparison. Results. In most tasks, visual function was impaired in youths with low vision. Substantial differences, however, were found both between participant groups and, importantly, across different tasks within participant groups. Foveal visual acuity was a modest predictor of peripheral form vision and motion sensitivity in either the central or peripheral field. Despite exhibiting normal motion discriminations in fovea, motion sensitivity of youths with low vision deteriorated in the periphery. This contrasted with typically sighted participants, who showed improved motion sensitivity with increasing eccentricity. Visual search was greatly impaired in youths with low vision. Conclusions. Our results reveal a complex pattern of visual deficits in peripheral vision and indicate a significant role of attentional mechanisms in observed impairments. These deficits were not adequately captured by measures of foveal function, arguing for the importance of independently assessing peripheral visual function. PMID:22836766

  18. Peripheral vision of youths with low vision: motion perception, crowding, and visual search.

    PubMed

    Tadin, Duje; Nyquist, Jeffrey B; Lusk, Kelly E; Corn, Anne L; Lappin, Joseph S

    2012-08-24

    Effects of low vision on peripheral visual function are poorly understood, especially in children whose visual skills are still developing. The aim of this study was to measure both central and peripheral visual functions in youths with typical and low vision. Of specific interest was the extent to which measures of foveal function predict performance of peripheral tasks. We assessed central and peripheral visual functions in youths with typical vision (n = 7, ages 10-17) and low vision (n = 24, ages 9-18). Experimental measures used both static and moving stimuli and included visual crowding, visual search, motion acuity, motion direction discrimination, and multitarget motion comparison. In most tasks, visual function was impaired in youths with low vision. Substantial differences, however, were found both between participant groups and, importantly, across different tasks within participant groups. Foveal visual acuity was a modest predictor of peripheral form vision and motion sensitivity in either the central or peripheral field. Despite exhibiting normal motion discriminations in fovea, motion sensitivity of youths with low vision deteriorated in the periphery. This contrasted with typically sighted participants, who showed improved motion sensitivity with increasing eccentricity. Visual search was greatly impaired in youths with low vision. Our results reveal a complex pattern of visual deficits in peripheral vision and indicate a significant role of attentional mechanisms in observed impairments. These deficits were not adequately captured by measures of foveal function, arguing for the importance of independently assessing peripheral visual function.

  19. Evaluating the performance of the quick CSF method in detecting contrast sensitivity function changes

    PubMed Central

    Hou, Fang; Lesmes, Luis Andres; Kim, Woojae; Gu, Hairong; Pitt, Mark A.; Myung, Jay I.; Lu, Zhong-Lin

    2016-01-01

    The contrast sensitivity function (CSF) has shown promise as a functional vision endpoint for monitoring the changes in functional vision that accompany eye disease or its treatment. However, detecting CSF changes with precision and efficiency at both the individual and group levels is very challenging. By exploiting the Bayesian foundation of the quick CSF method (Lesmes, Lu, Baek, & Albright, 2010), we developed and evaluated metrics for detecting CSF changes at both the individual and group levels. A 10-letter identification task was used to assess the systematic changes in the CSF measured in three luminance conditions in 112 naïve normal observers. The data from the large sample allowed us to estimate the test–retest reliability of the quick CSF procedure and evaluate its performance in detecting CSF changes at both the individual and group levels. The test–retest reliability reached 0.974 with 50 trials. In 50 trials, the quick CSF method can detect a medium 0.30 log unit area under log CSF change with 94.0% accuracy at the individual observer level. At the group level, a power analysis based on the empirical distribution of CSF changes from the large sample showed that a very small area under log CSF change (0.025 log unit) could be detected by the quick CSF method with 112 observers and 50 trials. These results make it plausible to apply the method to monitor the progression of visual diseases or treatment effects on individual patients and greatly reduce the time, sample size, and costs in clinical trials at the group level. PMID:27120074

  20. Moderate perinatal thyroid hormone insufficiency alters visual system function in adult rats.

    PubMed

    Boyes, William K; Degn, Laura; George, Barbara Jane; Gilbert, Mary E

    2018-04-21

    Thyroid hormone (TH) is critical for many aspects of neurodevelopment and can be disrupted by a variety of environmental contaminants. Sensory systems, including audition and vision are vulnerable to TH insufficiencies, but little data are available on visual system development at less than severe levels of TH deprivation. The goal of the current experiments was to explore dose-response relations between graded levels of TH insufficiency during development and the visual function of adult offspring. Pregnant Long Evans rats received 0 or 3 ppm (Experiment 1), or 0, 1, 2, or 3 ppm (Experiment 2) of propylthiouracil (PTU), an inhibitor of thyroid hormone synthesis, in drinking water from gestation day (GD) 6 to postnatal day (PN) 21. Treatment with PTU caused dose-related reductions of serum T4, with recovery on termination of exposure, and euthyroidism by the time of visual function testing. Tests of retinal (electroretinograms; ERGs) and visual cortex (visual evoked potentials; VEPs) function were assessed in adult offspring. Dark-adapted ERG a-waves, reflecting rod photoreceptors, were increased in amplitude by PTU. Light-adapted green flicker ERGs, reflecting M-cone photoreceptors, were reduced by PTU exposure. UV-flicker ERGs, reflecting S-cones, were not altered. Pattern-elicited VEPs were significantly reduced by 2 and 3 ppm PTU across a range of stimulus contrast values. The slope of VEP amplitude-log contrast functions was reduced by PTU, suggesting impaired visual contrast gain. Visual contrast gain primarily reflects function of visual cortex, and is responsible for adjusting sensitivity of perceptual mechanisms in response to changing visual scenes. The results indicate that moderate levels of pre-and post-natal TH insufficiency led to alterations in visual function of adult rats, including both retinal and visual cortex sites of dysfunction. Copyright © 2018. Published by Elsevier B.V.

  1. Quantity and Quality of Vision Using Tinted Filters in Patients with Low Vision Due to Diabetic Retinopathy.

    PubMed

    Sadeghpour, Naser; Alishiri, Ali Agha; Ajudani, Reza; Khosravi, Mohammad Hossein; Amiri, Mohammad Aghazadeh; Sadeghpour, Omid

    2015-01-01

    To investigate the effect of tinted filters on visual acuity (VA), contrast sensitivity and patient satisfaction in diabetic retinopathy associated with low vision. In a prospective study, 51 patients with diabetic retinopathy and low vision were assessed. We chose a simple random sampling method and used the patient's files for data collection. LogMAR notations were applied for assessing VA and a contrast sensitivity chart (CSV-1000) was employed for measuring contrast sensitivity. First, measurements were performed without tinted filters and then using them. Appropriate lenses were given to the patients for 2 days, and they were questioned about their satisfaction using them in different places. A total of 20 male and 31 female patients with mean age of 57.3 years participated in the study. With a 527 ± 10 nm filter, mean VA improved significantly (P ≤ 0.05). Using the 527 ± 10 nm and 511 ± 10 nm filters, mean contrast sensitivity was improved significantly at 3 and 6 cycles/degree frequencies (P < 0.05). The effect of other filters on VA and contrast sensitivity was not significant. Patient satisfaction rate was generally high. Tinted filters are able to rehabilitate low-vision patients due to diabetic retinopathy. The 527 ± 10 and 511 ± 10 nm wavelength filters improved contrast sensitivity and the 527 ± 10 nm filter improved VA to some extent. Further investigations are recommended to assess the effect of these filters in patients with other causes of low-vision.

  2. MPO4:Nd3+ (M=Ca, Gd), Luminomagnetic Nanophosphors with Optical and Magnetic Features for Multimodal Imaging Applications

    NASA Astrophysics Data System (ADS)

    Rightsell, Chris; Mimun, Lawrence C.; Kumar, Ajith G.; Sardar, Dhiraj K.

    2015-03-01

    Nanomaterials with multiple functionalities play a very important role in several high technology applications. A major area of such applications is the biomedical industry, where contrast agents with multiple imaging modalities can provide better results than conventional materials. Many of the contrast agents available now have drawbacks such as toxicity, photobleaching, low contrast, size restrictions, and overall cost of the imaging system. Rare-earth doped inorganic nanophosphors are alternatives to circumvent several of these issues, together with the added advantage of super high resolution imaging due to the excellent near infrared sensitivity of the phosphors. In addition to optical imaging features, by adding a magnetic ion such as Gd3+ at suitable lattice positions, the phosphor can be made magnetic, yielding dual imaging functionalities. In this research, we are presenting the optical and magnetic imaging features of sub-nanometer size MPO4:Nd3+ (M=Ca, Gd) phosphors for the potential application of these nanophosphors as multimodal contrast agents. Cytotoxicity, in vitro and in vivo imaging, penetration depth etc. are studied for various phosphor compositions, and optimized compositions are explored. This research was funded by the National Science Foundation Partnerships for Research and Education in Materials (NSF-PREM) Grant N0-DMR-0934218.

  3. VIP: Vortex Image Processing Package for High-contrast Direct Imaging

    NASA Astrophysics Data System (ADS)

    Gomez Gonzalez, Carlos Alberto; Wertz, Olivier; Absil, Olivier; Christiaens, Valentin; Defrère, Denis; Mawet, Dimitri; Milli, Julien; Absil, Pierre-Antoine; Van Droogenbroeck, Marc; Cantalloube, Faustine; Hinz, Philip M.; Skemer, Andrew J.; Karlsson, Mikael; Surdej, Jean

    2017-07-01

    We present the Vortex Image Processing (VIP) library, a python package dedicated to astronomical high-contrast imaging. Our package relies on the extensive python stack of scientific libraries and aims to provide a flexible framework for high-contrast data and image processing. In this paper, we describe the capabilities of VIP related to processing image sequences acquired using the angular differential imaging (ADI) observing technique. VIP implements functionalities for building high-contrast data processing pipelines, encompassing pre- and post-processing algorithms, potential source position and flux estimation, and sensitivity curve generation. Among the reference point-spread function subtraction techniques for ADI post-processing, VIP includes several flavors of principal component analysis (PCA) based algorithms, such as annular PCA and incremental PCA algorithms capable of processing big datacubes (of several gigabytes) on a computer with limited memory. Also, we present a novel ADI algorithm based on non-negative matrix factorization, which comes from the same family of low-rank matrix approximations as PCA and provides fairly similar results. We showcase the ADI capabilities of the VIP library using a deep sequence on HR 8799 taken with the LBTI/LMIRCam and its recently commissioned L-band vortex coronagraph. Using VIP, we investigated the presence of additional companions around HR 8799 and did not find any significant additional point source beyond the four known planets. VIP is available at http://github.com/vortex-exoplanet/VIP and is accompanied with Jupyter notebook tutorials illustrating the main functionalities of the library.

  4. Dispersion and shape engineered plasmonic nanosensors

    NASA Astrophysics Data System (ADS)

    Jeong, Hyeon-Ho; Mark, Andrew G.; Alarcón-Correa, Mariana; Kim, Insook; Oswald, Peter; Lee, Tung-Chun; Fischer, Peer

    2016-04-01

    Biosensors based on the localized surface plasmon resonance (LSPR) of individual metallic nanoparticles promise to deliver modular, low-cost sensing with high-detection thresholds. However, they continue to suffer from relatively low sensitivity and figures of merit (FOMs). Herein we introduce the idea of sensitivity enhancement of LSPR sensors through engineering of the material dispersion function. Employing dispersion and shape engineering of chiral nanoparticles leads to remarkable refractive index sensitivities (1,091 nm RIU-1 at λ=921 nm) and FOMs (>2,800 RIU-1). A key feature is that the polarization-dependent extinction of the nanoparticles is now characterized by rich spectral features, including bipolar peaks and nulls, suitable for tracking refractive index changes. This sensing modality offers strong optical contrast even in the presence of highly absorbing media, an important consideration for use in complex biological media with limited transmission. The technique is sensitive to surface-specific binding events which we demonstrate through biotin-avidin surface coupling.

  5. A multi-component nanocomposite screen-printed ink with non-linear touch sensitive electrical conductivity

    NASA Astrophysics Data System (ADS)

    Webb, Alexander J.; Szablewski, Marek; Bloor, David; Atkinson, Del; Graham, Adam; Laughlin, Paul; Lussey, David

    2013-04-01

    Printable electronics is an innovative area of technology with great commercial potential. Here, a screen-printed functional ink, comprising a combination of semiconducting acicular particles, electrically insulating nanoparticles and a base polymer ink, is described that exhibits pronounced pressure sensitive electrical properties for applications in sensing and touch sensitive surfaces. The combination of these components in the as-printed ink yield a complex structure and a large and reproducible touch pressure sensitive resistance range. In contrast to the case for some composite systems, the resistance changes occur down to applied pressures of 13 Pa. Current-voltage measurements at fixed pressures show monotonic non-linear behaviour, which becomes more Ohmic at higher pressures and in all cases shows some hysteresis. The physical basis for conduction, particularly in the low pressure regime, can be described in terms of field assisted quantum mechanical tunnelling.

  6. Positive contrast of SPIO-labeled cells by off-resonant reconstruction of 3D radial half-echo bSSFP.

    PubMed

    Diwoky, Clemens; Liebmann, Daniel; Neumayer, Bernhard; Reinisch, Andreas; Knoll, Florian; Strunk, Dirk; Stollberger, Rudolf

    2015-01-01

    This article describes a new acquisition and reconstruction concept for positive contrast imaging of cells labeled with superparamagnetic iron oxides (SPIOs). Overcoming the limitations of a negative contrast representation as gained with gradient echo and fully balanced steady state (bSSFP), the proposed method delivers a spatially localized contrast with high cellular sensitivity not accomplished by other positive contrast methods. Employing a 3D radial bSSFP pulse sequence with half-echo sampling, positive cellular contrast is gained by adding artificial global frequency offsets to each half-echo before image reconstruction. The new contrast regime is highlighted with numerical intravoxel simulations including the point-spread function for 3D half-echo acquisitions. Furthermore, the new method is validated on the basis of in vitro cell phantom measurements on a clinical MRI platform, where the measured contrast-to-noise ratio (CNR) of the new approach exceeds even the negative contrast of bSSFP. Finally, an in vivo proof of principle study based on a mouse model with a clear depiction of labeled cells within a subcutaneous cell islet containing a cell density as low as 7 cells/mm(3) is presented. The resultant isotropic images show robustness to motion and a high CNR, in addition to an enhanced specificity due to the positive contrast of SPIO-labeled cells. Copyright © 2014 John Wiley & Sons, Ltd.

  7. Neutral vs positive oral contrast in diagnosing acute appendicitis with contrast-enhanced CT: sensitivity, specificity, reader confidence and interpretation time

    PubMed Central

    Naeger, D M; Chang, S D; Kolli, P; Shah, V; Huang, W; Thoeni, R F

    2011-01-01

    Objective The study compared the sensitivity, specificity, confidence and interpretation time of readers of differing experience in diagnosing acute appendicitis with contrast-enhanced CT using neutral vs positive oral contrast agents. Methods Contrast-enhanced CT for right lower quadrant or right flank pain was performed in 200 patients with neutral and 200 with positive oral contrast including 199 with proven acute appendicitis and 201 with other diagnoses. Test set disease prevalence was 50%. Two experienced gastrointestinal radiologists, one fellow and two first-year residents blindly assessed all studies for appendicitis (2000 readings) and assigned confidence scores (1=poor to 4=excellent). Receiver operating characteristic (ROC) curves were generated. Total interpretation time was recorded. Each reader's interpretation with the two agents was compared using standard statistical methods. Results Average reader sensitivity was found to be 96% (range 91–99%) with positive and 95% (89–98%) with neutral oral contrast; specificity was 96% (92–98%) and 94% (90–97%). For each reader, no statistically significant difference was found between the two agents (sensitivities p-values >0.6; specificities p-values>0.08), in the area under the ROC curve (range 0.95–0.99) or in average interpretation times. In cases without appendicitis, positive oral contrast demonstrated improved appendix identification (average 90% vs 78%) and higher confidence scores for three readers. Average interpretation times showed no statistically significant differences between the agents. Conclusion Neutral vs positive oral contrast does not affect the accuracy of contrast-enhanced CT for diagnosing acute appendicitis. Although positive oral contrast might help to identify normal appendices, we continue to use neutral oral contrast given its other potential benefits. PMID:20959365

  8. Colour discrimination and categorisation in Williams syndrome.

    PubMed

    Farran, Emily K; Cranwell, Matthew B; Alvarez, James; Franklin, Anna

    2013-10-01

    Individuals with Williams syndrome (WS) present with impaired functioning of the dorsal visual stream relative to the ventral visual stream. As such, little attention has been given to ventral stream functions in WS. We investigated colour processing, a predominantly ventral stream function, for the first time in nineteen individuals with Williams syndrome. Colour discrimination was assessed using the Farnsworth-Munsell 100 hue test. Colour categorisation was assessed using a match-to-sample test and a colour naming task. A visual search task was also included as a measure of sensitivity to the size of perceptual colour difference. Results showed that individuals with WS have reduced colour discrimination relative to typically developing participants matched for chronological age; performance was commensurate with a typically developing group matched for non-verbal ability. In contrast, categorisation was typical in WS, although there was some evidence that sensitivity to the size of perceptual colour differences was reduced in this group. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Circadian perinatal photoperiod has enduring effects on retinal dopamine and visual function.

    PubMed

    Jackson, Chad R; Capozzi, Megan; Dai, Heng; McMahon, Douglas G

    2014-03-26

    Visual system development depends on neural activity, driven by intrinsic and light-sensitive mechanisms. Here, we examined the effects on retinal function due to exposure to summer- and winter-like circadian light cycles during development and adulthood. Retinal light responses, visual behaviors, dopamine content, retinal morphology, and gene expression were assessed in mice reared in seasonal photoperiods consisting of light/dark cycles of 8:16, 16:8, and 12:12 h, respectively. Mice exposed to short, winter-like, light cycles showed enduring deficits in photopic retinal light responses and visual contrast sensitivity, but only transient changes were observed for scotopic measures. Dopamine levels were significantly lower in short photoperiod mice, and dopaminergic agonist treatment rescued the photopic light response deficits. Tyrosine hydroxylase and Early Growth Response factor-1 mRNA expression were reduced in short photoperiod retinas. Therefore, seasonal light cycles experienced during retinal development and maturation have lasting influence on retinal and visual function, likely through developmental programming of retinal dopamine.

  10. Molecular Evolution of the Tissue-nonspecific Alkaline Phosphatase Allows Prediction and Validation of Missense Mutations Responsible for Hypophosphatasia*

    PubMed Central

    Silvent, Jérémie; Gasse, Barbara; Mornet, Etienne; Sire, Jean-Yves

    2014-01-01

    ALPL encodes the tissue nonspecific alkaline phosphatase (TNSALP), which removes phosphate groups from various substrates. Its function is essential for bone and tooth mineralization. In humans, ALPL mutations lead to hypophosphatasia, a genetic disorder characterized by defective bone and/or tooth mineralization. To date, 275 ALPL mutations have been reported to cause hypophosphatasia, of which 204 were simple missense mutations. Molecular evolutionary analysis has proved to be an efficient method to highlight residues important for the protein function and to predict or validate sensitive positions for genetic disease. Here we analyzed 58 mammalian TNSALP to identify amino acids unchanged, or only substituted by residues sharing similar properties, through 220 millions years of mammalian evolution. We found 469 sensitive positions of the 524 residues of human TNSALP, which indicates a highly constrained protein. Any substitution occurring at one of these positions is predicted to lead to hypophosphatasia. We tested the 204 missense mutations resulting in hypophosphatasia against our predictive chart, and validated 99% of them. Most sensitive positions were located in functionally important regions of TNSALP (active site, homodimeric interface, crown domain, calcium site, …). However, some important positions are located in regions, the structure and/or biological function of which are still unknown. Our chart of sensitive positions in human TNSALP (i) enables to validate or invalidate at low cost any ALPL mutation, which would be suspected to be responsible for hypophosphatasia, by contrast with time consuming and expensive functional tests, and (ii) displays higher predictive power than in silico models of prediction. PMID:25023282

  11. Contrast adaptation induced by defocus - a possible error signal for emmetropization?

    PubMed

    Ohlendorf, Arne; Schaeffel, Frank

    2009-01-01

    To describe some features of contrast adaptation as induced by imposed positive or negative defocus. To study its time course and selectivity for the sign of the imposed defocus. Contrast adaptation, CA (here referred to as any change in supra-threshold contrast sensitivity) was induced by presenting a movie to the subjects on a computer screen at 1m distance for 10min, while the right eye was defocused by a trial lens (+4D (n=25); -4D (n=10); -2D (n=11 subjects). The PowerRefractor was used to track accommodation binocularly. Contrast sensitivity at threshold was measured by a method of adjustment with a Gabor patch of 1deg angular subtense, filled with 3.22cyc/deg sine wave grating presented on a computer screen at 1m distance on gray background (33cd/m(2)). Supra-threshold contrast sensitivity was quantified by an interocular contrast matching task, in which the subject had to match the contrast of the sine wave grating seen with the right eye with the contrast of a grating with fixed contrast of 0.1. (1) Contrast sensitivity thresholds were not lowered by previous viewing of defocused movies. (2) By wearing positive lenses, the supra-threshold contrast sensitivity in the right eye was raised by about 30% and remained elevated for at least 2min until baseline was reached after about 5min. (3) CA was induced only by positive, but not by negative lenses, even after the distance of the computer screen was taken into account (1m, equivalent to +1D). In five subjects, binocular accommodation was tracked over the full adaptation period. Accommodation appeared to focus the eye not wearing a lens, but short transient switches in focus to the lens wearing eye could not be entirely excluded. Transient contrast adaptation was found at 3.22cyc/deg when positive lenses were worn but not with negative lenses. This asymmetry is intriguing. While it may represent an epiphenomenon of physiological optics, further experiments are necessary to determine whether it could also trace back to differences in CA with defocus of different sign.

  12. Lung tumors with distinct p53 mutations respond similarly to p53 targeted therapy but exhibit genotype-specific statin sensitivity

    PubMed Central

    Turrell, Frances K.; Kerr, Emma M.; Gao, Meiling; Thorpe, Hannah; Doherty, Gary J.; Cridge, Jake; Shorthouse, David; Speed, Alyson; Samarajiwa, Shamith; Hall, Benjamin A.; Griffiths, Meryl; Martins, Carla P.

    2017-01-01

    Lung adenocarcinoma accounts for ∼40% of lung cancers, the leading cause of cancer-related death worldwide, and current therapies provide only limited survival benefit. Approximately half of lung adenocarcinomas harbor mutations in TP53 (p53), making these mutants appealing targets for lung cancer therapy. As mutant p53 remains untargetable, mutant p53-dependent phenotypes represent alternative targeting opportunities, but the prevalence and therapeutic relevance of such effects (gain of function and dominant-negative activity) in lung adenocarcinoma are unclear. Through transcriptional and functional analysis of murine KrasG12D-p53null, -p53R172H (conformational), and -p53R270H (contact) mutant lung tumors, we identified genotype-independent and genotype-dependent therapeutic sensitivities. Unexpectedly, we found that wild-type p53 exerts a dominant tumor-suppressive effect on mutant tumors, as all genotypes were similarly sensitive to its restoration in vivo. These data show that the potential of p53 targeted therapies is comparable across all p53-deficient genotypes and may explain the high incidence of p53 loss of heterozygosity in mutant tumors. In contrast, mutant p53 gain of function and their associated vulnerabilities can vary according to mutation type. Notably, we identified a p53R270H-specific sensitivity to simvastatin in lung tumors, and the transcriptional signature that underlies this sensitivity was also present in human lung tumors, indicating that this therapeutic approach may be clinically relevant. PMID:28790158

  13. Recent development of nanoparticles for molecular imaging

    NASA Astrophysics Data System (ADS)

    Kim, Jonghoon; Lee, Nohyun; Hyeon, Taeghwan

    2017-10-01

    Molecular imaging enables us to non-invasively visualize cellular functions and biological processes in living subjects, allowing accurate diagnosis of diseases at early stages. For successful molecular imaging, a suitable contrast agent with high sensitivity is required. To date, various nanoparticles have been developed as contrast agents for medical imaging modalities. In comparison with conventional probes, nanoparticles offer several advantages, including controllable physical properties, facile surface modification and long circulation time. In addition, they can be integrated with various combinations for multimodal imaging and therapy. In this opinion piece, we highlight recent advances and future perspectives of nanomaterials for molecular imaging. This article is part of the themed issue 'Challenges for chemistry in molecular imaging'.

  14. Floaters and reduced contrast sensitivity after successful pharmacologic vitreolysis with ocriplasmin.

    PubMed

    Khoshnevis, Matin; Nguyen-Cuu, Jeannie; Sebag, J

    2016-12-01

    To describe the onset of floaters and reduction in contrast sensitivity (CS) following successful pharmacologic vitreolysis with ocriplasmin for the treatment of vitreo-macular traction (VMT) in a patient with previously normal CS. A 65-year-old woman with a past ocular history of normal visual acuity (VA = 20/26) and contrast sensitivity (1.81% Weber) presents with a 4-month history of distortions. VA decreased to 20/40 and Optical Coherence Tomography (OCT) demonstrated VMT. Pharmacologic vitreolysis was performed with intravitreal ocriplasmin. Ten weeks later the patient complained of floaters and was found to have a PVD and complete resolution of VMT. VA was still 20/40, but contrast sensitivity decreased by more than 100% to 3.77%Weber. After 6 months of attempted coping, this did not improve, so limited vitrectomy was performed. Post-operative VA = 20/26 and CS improved by 46% from 3.77%W to 2.03%W (normal). and importance: This case highlights a little discussed consequence of PVD induction by successful pharmacologic vitreolysis - the development of clinically significant floaters. The resulting reduction of contrast sensitivity was normalized by limited vitrectomy, strongly suggesting that the detached vitreous was the cause.

  15. A multi-center preclinical study of gadoxetate DCE-MRI in rats as a biomarker of drug induced inhibition of liver transporter function

    PubMed Central

    Lenhard, Stephen C.; Yerby, Brittany; Forsgren, Mikael F.; Liachenko, Serguei; Johansson, Edvin; Pilling, Mark A.; Peterson, Richard A.; Yang, Xi; Williams, Dominic P.; Ungersma, Sharon E.; Morgan, Ryan E.; Brouwer, Kim L. R.; Jucker, Beat M.; Hockings, Paul D.

    2018-01-01

    Drug-induced liver injury (DILI) is a leading cause of acute liver failure and transplantation. DILI can be the result of impaired hepatobiliary transporters, with altered bile formation, flow, and subsequent cholestasis. We used gadoxetate dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), combined with pharmacokinetic modelling, to measure hepatobiliary transporter function in vivo in rats. The sensitivity and robustness of the method was tested by evaluating the effect of a clinical dose of the antibiotic rifampicin in four different preclinical imaging centers. The mean gadoxetate uptake rate constant for the vehicle groups at all centers was 39.3 +/- 3.4 s-1 (n = 23) and 11.7 +/- 1.3 s-1 (n = 20) for the rifampicin groups. The mean gadoxetate efflux rate constant for the vehicle groups was 1.53 +/- 0.08 s-1 (n = 23) and for the rifampicin treated groups was 0.94 +/- 0.08 s-1 (n = 20). Both the uptake and excretion transporters of gadoxetate were statistically significantly inhibited by the clinical dose of rifampicin at all centers and the size of this treatment group effect was consistent across the centers. Gadoxetate is a clinically approved MRI contrast agent, so this method is readily transferable to the clinic. Conclusion: Rate constants of gadoxetate uptake and excretion are sensitive and robust biomarkers to detect early changes in hepatobiliary transporter function in vivo in rats prior to established biomarkers of liver toxicity. PMID:29771932

  16. Effect of Ginkgo biloba on visual field and contrast sensitivity in Chinese patients with normal tension glaucoma: a randomized, crossover clinical trial.

    PubMed

    Guo, Xinxing; Kong, Xiangbin; Huang, Rui; Jin, Ling; Ding, Xiaohu; He, Mingguang; Liu, Xing; Patel, Mehul Chimanlal; Congdon, Nathan G

    2014-01-07

    We evaluated the effect of ginkgo biloba extract on visual field defect and contrast sensitivity in a Chinese cohort with normal tension glaucoma. In this prospective, randomized, placebo-controlled crossover study, patients newly diagnosed with normal tension glaucoma, either in a tertiary glaucoma clinic (n = 5) or in a cohort undergoing routine general physical examinations in a primary care clinic (n = 30), underwent two 4-week phases of treatment, separated by a washout period of 8 weeks. Randomization determined whether ginkgo biloba extract (40 mg, 3 times per day) or placebo (identical-appearing tablets) was received first. Primary outcomes were change in contrast sensitivity and mean deviation on 24-2 SITA standard visual field testing, while secondary outcomes included IOP and self-reported adverse events. A total of 35 patients with mean age 63.7 (6.5) years were randomized to the ginkgo biloba extract-placebo (n = 18) or the placebo-ginkgo biloba extract (n = 17) sequence. A total of 28 patients (80.0%, 14 in each group) who completed testing did not differ at baseline in age, sex, visual field mean deviation, contrast sensitivity, IOP, or blood pressure. Changes in visual field and contrast sensitivity did not differ by treatment received or sequence (P > 0.2 for all). Power to have detected a difference in mean defect as large as previously reported was 80%. In contrast to some previous reports, ginkgo biloba extract treatment had no effect on mean defect or contrast sensitivity in this group of normal tension glaucoma patients. (http://www.chictr.org number, ChiCTR-TRC-08000724).

  17. Non-contrast MRI diagnosis of adhesive capsulitis of the shoulder.

    PubMed

    Chi, Andrew S; Kim, John; Long, Suzanne S; Morrison, William B; Zoga, Adam C

    To investigate non-contrast MRI findings of clinical adhesive capsulitis. 31 non-contrast, non-arthrographic, shoulder MRIs were evaluated for coracohumeral ligament thickness, rotator interval infiltration, and axillary recess thickening/edema. In detection of adhesive capsulitis, sensitivity is 76.7% and specificity is 53.3% for coracohumeral ligament thickening, sensitivity is 66.7% and specificity is 55.2% for coracohumeral ligament thickening and rotator interval infiltration, and sensitivity is 23.3% and specificity is 86.7% for coracohumeral ligament thickening, rotator interval infiltration, and axillary recess thickening/edema. Adhesive capsulitis can be accurately diagnosed on non-contrast MRI shoulder examinations with appropriate clinical criteria without direct MR arthrography. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Proteasome phosphorylation regulates cocaine-induced sensitization.

    PubMed

    Gonzales, Frankie R; Howell, Kristin K; Dozier, Lara E; Anagnostaras, Stephan G; Patrick, Gentry N

    2018-04-01

    Repeated exposure to cocaine produces structural and functional modifications at synapses from neurons in several brain regions including the nucleus accumbens. These changes are thought to underlie cocaine-induced sensitization. The ubiquitin proteasome system plays a crucial role in the remodeling of synapses and has recently been implicated in addiction-related behavior. The ATPase Rpt6 subunit of the 26S proteasome is phosphorylated by Ca 2+ /calmodulin-dependent protein kinases II alpha at ser120 which is thought to regulate proteasome activity and distribution in neurons. Here, we demonstrate that Rpt6 phosphorylation is involved in cocaine-induced locomotor sensitization. Cocaine concomitantly increases proteasome activity and Rpt6 S120 phosphorylation in cultured neurons and in various brain regions of wild type mice including the nucleus accumbens and prefrontal cortex. In contrast, cocaine does not increase proteasome activity in Rpt6 phospho-mimetic (ser120Asp) mice. Strikingly, we found a complete absence of cocaine-induced locomotor sensitization in the Rpt6 ser120Asp mice. Together, these findings suggest a critical role for Rpt6 phosphorylation and proteasome function in the regulation cocaine-induced behavioral plasticity. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Visual motion perception predicts driving hazard perception ability.

    PubMed

    Lacherez, Philippe; Au, Sandra; Wood, Joanne M

    2014-02-01

    To examine the basis of previous findings of an association between indices of driving safety and visual motion sensitivity and to examine whether this association could be explained by low-level changes in visual function. A total of 36 visually normal participants (aged 19-80 years) completed a battery of standard vision tests including visual acuity, contrast sensitivity and automated visual fields and two tests of motion perception including sensitivity for movement of a drifting Gabor stimulus and sensitivity for displacement in a random dot kinematogram (Dmin ). Participants also completed a hazard perception test (HPT), which measured participants' response times to hazards embedded in video recordings of real-world driving, which has been shown to be linked to crash risk. Dmin for the random dot stimulus ranged from -0.88 to -0.12 log minutes of arc, and the minimum drift rate for the Gabor stimulus ranged from 0.01 to 0.35 cycles per second. Both measures of motion sensitivity significantly predicted response times on the HPT. In addition, while the relationship involving the HPT and motion sensitivity for the random dot kinematogram was partially explained by the other visual function measures, the relationship with sensitivity for detection of the drifting Gabor stimulus remained significant even after controlling for these variables. These findings suggest that motion perception plays an important role in the visual perception of driving-relevant hazards independent of other areas of visual function and should be further explored as a predictive test of driving safety. Future research should explore the causes of reduced motion perception to develop better interventions to improve road safety. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.

  20. Physical and functional interactions between a glioma cation channel and integrin-β1 require α-actinin

    PubMed Central

    Rooj, Arun K.; Liu, Zhiyong; McNicholas, Carmel M.

    2015-01-01

    Major plasma membrane components of the tumor cell, ion channels, and integrins play crucial roles in metastasis. Glioma cells express an amiloride-sensitive nonselective cation channel composed of acid-sensing ion channel (ASIC)-1 and epithelial Na+ channel (ENaC) α- and γ-subunits. Inhibition of this channel is associated with reduced cell migration and proliferation. Using the ASIC-1 subunit as a reporter for the channel complex, we found a physical and functional interaction between this channel and integrin-β1. Short hairpin RNA knockdown of integrin-β1 attenuated the amiloride-sensitive current, which was due to loss of surface expression of ASIC-1. In contrast, upregulation of membrane expression of integrin-β1 increased the surface expression of ASIC-1. The link between the amiloride-sensitive channel and integrin-β1 was mediated by α-actinin. Downregulation of α-actinin-1 or -4 attenuated the amiloride-sensitive current. Mutation of the putative binding site for α-actinin on the COOH terminus of ASIC-1 reduced the membrane localization of ASIC-1 and also resulted in attenuation of the amiloride-sensitive current. Our data suggest a novel interaction between the amiloride-sensitive glioma cation channel and integrin-β1, mediated by α-actinin. This interaction may form a mechanism by which channel activity can regulate glioma cell proliferation and migration. PMID:26108662

  1. Relationships Between Measures of the Ability to Perform Vision-Related Activities, Vision-Related Quality of Life, and Clinical Findings in Patients With Glaucoma.

    PubMed

    Ekici, Feyzahan; Loh, Rebecca; Waisbourd, Michael; Sun, Yi; Martinez, Patricia; Nayak, Natasha; Wizov, Sheryl S; Hegarty, Sarah; Hark, Lisa A; Spaeth, George L

    2015-12-01

    To our knowledge, few studies have combined an objective measure of vision-related performance (VRP) and subjective measures of vision-related quality of life (VRQoL) with clinically related visual parameters, particularly in a large, prospective, cohort study setting. To examine the relationships between clinical visual assessments and both a VRP and 2 self-reported VRQoL measurements. Patients (N = 161) with moderate-stage glaucoma recruited from the Glaucoma Service at Wills Eye Hospital, Philadelphia, Pennsylvania, were enrolled from May 2012 to May 2014 in an ongoing prospective, 4-year longitudinal observational study. This report includes cross-sectional results from the baseline visit. Patients received a complete ocular examination, automated visual field (VF) test and Cirrus optical coherence tomographic scan. Contrast sensitivity was measured with the Pelli-Robson and the Spaeth-Richman Contrast Sensitivity (SPARCS) tests. Vision-related performance was assessed by the Compressed Assessment of Ability Related to Vision (CAARV) test. Vision-related QoL was assessed by the National Eye Institute Visual Function Questionnaire 25 (NEI-VFQ-25) and a modified Glaucoma Symptom Scale (MGSS). Correlations between clinical measures and CAARV, NEI-VFQ-25, and MGSS scores. A total of 161 patients were enrolled in the study. The strongest correlation was found between SPARCS score in the better eye and total CAARV score (r = 0.398; 95% CI, 0.235-0.537; P < .001). The CAARV score also correlated with the Pelli-Robson score (r = 0.353; 95% CI, 0.186-0.499; P = .001), VF mean deviation (r = 0.366; 95% CI, 0.200-0.510; P < .001), and VA (r = -0.326, 95% CI = -0.476 to -0.157; P = .003) in the better eye. There were more statistically significant correlations between contrast sensitivity tests and VF mean deviation with VRQoL measurements than with other clinical measures (visual acuity, intraocular pressure, Disc Damage Likelihood Scale, and mean retinal nerve fiber layer thickness). The MGSS scores were lower (worse) in women compared with men (P = .03 for binocular, P = .01 for better eye, and P = .05 for the worse eye). Structural measures (eg, Disc Damage Likelihood Scale, and retinal nerve fiber layer thickness) were generally not informative with respect to VRP or VRQoL. Contrast sensitivity tests and VF mean deviation were associated with both objective measures of the ability to act and subjective measurements of VRQoL. The strongest correlation was between SPARCS score (contrast sensitivity) in the better eye and total CAARV score. Therefore, measurement of contrast sensitivity should be considered when evaluating patients' VRQoL. The results of this study were limited by the patient population and apply only within the bounds of the tested cohort.

  2. CD4 T lymphocytes from patients with chronic fatigue syndrome have decreased interferon-gamma production and increased sensitivity to dexamethasone.

    PubMed

    Visser, J; Blauw, B; Hinloopen, B; Brommer, E; de Kloet, E R; Kluft, C; Nagelkerken, L

    1998-02-01

    A disturbed hypothalamus-pituitary-adrenal gland axis and alterations at the immune system level have been observed in patients with chronic fatigue syndrome (CFS). Glucocorticoids are known to modulate T cell responses; therefore, purified CD4 T cells from CFS patients were studied to determine whether they have an altered sensitivity to dexamethasone (DEX). CD4 T cells from CFS patients produced less interferon-gamma than did cells from controls; by contrast, interleukin-4 production and cell proliferation were comparable. With CD4 T cells from CFS patients (compared with cells from controls), a 10- to 20-fold lower DEX concentration was needed to achieve 50% inhibition of interleukin-4 production and proliferation, indicating an increased sensitivity to DEX in CFS patients. Surprisingly, interferon-gamma production in patients and controls was equally sensitive to DEX. A differential sensitivity of cytokines or CD4 T cell subsets to glucocorticoids might explain an altered immunologic function in CFS patients.

  3. Polarization asymmetry in two-electron photodetachment - A cogent test of the ionization threshold law

    NASA Technical Reports Server (NTRS)

    Temkin, A.; Bhatia, A. K.

    1988-01-01

    A very sensitive test of the electron-atom ionization threshold law is suggested: for spin-aligned heavy negative ions it consists of measuring the polarization asymmetry A(PA) coming from double detachment by left- versus right-circularly polarized light. The respective yields are worked out for the Te(-) (5p)5 2P(3/2) ion. The Coulomb-dipole theory predicts A(PA) to be the ratio of two oscillating functions in sharp contrast to any power law (specifically that of Wannier, 1953) for which the ratio is expected to be a smooth function of energy.

  4. qCSF in Clinical Application: Efficient Characterization and Classification of Contrast Sensitivity Functions in Amblyopia

    PubMed Central

    Hou, Fang; Huang, Chang-Bing; Lesmes, Luis; Feng, Li-Xia; Tao, Liming; Zhou, Yi-Feng; Lu, Zhong-Lin

    2010-01-01

    Purpose. The qCSF method is a novel procedure for rapid measurement of spatial contrast sensitivity functions (CSFs). It combines Bayesian adaptive inference with a trial-to-trial information gain strategy, to directly estimate four parameters defining the observer's CSF. In the present study, the suitability of the qCSF method for clinical application was examined. Methods. The qCSF method was applied to rapidly assess spatial CSFs in 10 normal and 8 amblyopic participants. The qCSF was evaluated for accuracy, precision, test–retest reliability, suitability of CSF model assumptions, and accuracy of amblyopia screening. Results. qCSF estimates obtained with as few as 50 trials matched those obtained with 300 Ψ trials. The precision of qCSF estimates obtained with 120 and 130 trials, in normal subjects and amblyopes, matched the precision of 300 Ψ trials. For both groups and both methods, test–retest sensitivity estimates were well matched (all R > 0.94). The qCSF model assumptions were valid for 8 of 10 normal participants and all amblyopic participants. Measures of the area under log CSF (AULCSF) and the cutoff spatial frequency (cutSF) were lower in the amblyopia group; these differences were captured within 50 qCSF trials. Amblyopia was detected at an approximately 80% correct rate in 50 trials, when a logistic regression model was used with AULCSF and cutSF as predictors. Conclusions. The qCSF method is sufficiently rapid, accurate, and precise in measuring CSFs in normal and amblyopic persons. It has great potential for clinical practice. PMID:20484592

  5. High contrast sensitivity for visually guided flight control in bumblebees.

    PubMed

    Chakravarthi, Aravin; Kelber, Almut; Baird, Emily; Dacke, Marie

    2017-12-01

    Many insects rely on vision to find food, to return to their nest and to carefully control their flight between these two locations. The amount of information available to support these tasks is, in part, dictated by the spatial resolution and contrast sensitivity of their visual systems. Here, we investigate the absolute limits of these visual properties for visually guided position and speed control in Bombus terrestris. Our results indicate that the limit of spatial vision in the translational motion detection system of B. terrestris lies at 0.21 cycles deg -1 with a peak contrast sensitivity of at least 33. In the perspective of earlier findings, these results indicate that bumblebees have higher contrast sensitivity in the motion detection system underlying position control than in their object discrimination system. This suggests that bumblebees, and most likely also other insects, have different visual thresholds depending on the behavioral context.

  6. Lung function imaging methods in Cystic Fibrosis pulmonary disease.

    PubMed

    Kołodziej, Magdalena; de Veer, Michael J; Cholewa, Marian; Egan, Gary F; Thompson, Bruce R

    2017-05-17

    Monitoring of pulmonary physiology is fundamental to the clinical management of patients with Cystic Fibrosis. The current standard clinical practise uses spirometry to assess lung function which delivers a clinically relevant functional readout of total lung function, however does not supply any visible or localised information. High Resolution Computed Tomography (HRCT) is a well-established current 'gold standard' method for monitoring lung anatomical changes in Cystic Fibrosis patients. HRCT provides excellent morphological information, however, the X-ray radiation dose can become significant if multiple scans are required to monitor chronic diseases such as cystic fibrosis. X-ray phase-contrast imaging is another emerging X-ray based methodology for Cystic Fibrosis lung assessment which provides dynamic morphological and functional information, albeit with even higher X-ray doses than HRCT. Magnetic Resonance Imaging (MRI) is a non-ionising radiation imaging method that is garnering growing interest among researchers and clinicians working with Cystic Fibrosis patients. Recent advances in MRI have opened up the possibilities to observe lung function in real time to potentially allow sensitive and accurate assessment of disease progression. The use of hyperpolarized gas or non-contrast enhanced MRI can be tailored to clinical needs. While MRI offers significant promise it still suffers from poor spatial resolution and the development of an objective scoring system especially for ventilation assessment.

  7. Ambient illumination switches contrast preference of specific retinal processing streams

    PubMed Central

    Pearson, James T.

    2015-01-01

    Contrast, a fundamental feature of visual scenes, is encoded in a distributed manner by ∼20 retinal ganglion cell (RGC) types, which stream visual information to the brain. RGC types respond preferentially to positive (ONpref) or negative (OFFpref) contrast and differ in their sensitivity to preferred contrast and responsiveness to nonpreferred stimuli. Vision operates over an enormous range of mean light levels. The influence of ambient illumination on contrast encoding across RGC types is not well understood. Here, we used large-scale multielectrode array recordings to characterize responses of mouse RGCs under lighting conditions spanning five orders in brightness magnitude. We identify three functional RGC types that switch contrast preference in a luminance-dependent manner (Sw1-, Sw2-, and Sw3-RGCs). As ambient illumination increases, Sw1- and Sw2-RGCs shift from ONpref to OFFpref and Sw3-RGCs from OFFpref to ONpref. In all cases, transitions in contrast preference are reversible and track light levels. By mapping spatiotemporal receptive fields at different mean light levels, we find that changes in input from ON and OFF pathways in receptive field centers underlie shifts in contrast preference. Sw2-RGCs exhibit direction-selective responses to motion stimuli. Despite changing contrast preference, direction selectivity of Sw2-RGCs and other RGCs as well as orientation-selective responses of RGCs remain stable across light levels. PMID:25995351

  8. Interpretation of link fluctuations in climate networks during El Niño periods

    NASA Astrophysics Data System (ADS)

    Martin, E. A.; Paczuski, M.; Davidsen, J.

    2013-05-01

    Recent work has shown that the topologies of functional climate networks are sensitive to El Niño events. One important interpretation of the findings was that parts of the globe act in correlated relationships which become weaker, on average, during El Niño periods (this was shown using monthly averaged data where no time lag is required, and with daily averaged data where time lags were utilized). In contrast to this, we show that El Niño periods actually exhibit higher correlations than “Normal” climate conditions, while typically having lower correlations than La Niña periods. We also show that it is crucial to establish the sensitivity and the robustness of a given method used to extract functional climate networks —parameters such as time lags can significantly influence and even totally alter the outcome.

  9. Function of desiccate in gustatory sensilla of drosophila melanogaster.

    PubMed

    Kawano, Takeshi; Ryuda, Masasuke; Matsumoto, Hitoshi; Ochiai, Masanori; Oda, Yasunori; Tanimura, Teiichi; Csikos, Gyorge; Moriya, Megumi; Hayakawa, Yoichi

    2015-11-27

    Desiccate (Desi), initially discovered as a gene expressing in the epidermis of Drosophila larvae for protection from desiccation stress, was recently found to be robustly expressed in the adult labellum; however, the function, as well as precise expression sites, was unknown. Here, we found that Desi is expressed in two different types of non-neuronal cells of the labellum, the epidermis and thecogen accessory cells. Labellar Desi expression was significantly elevated under arid conditions, accompanied by an increase in water ingestion by adults. Desi overexpression also promoted water ingestion. In contrast, a knockdown of Desi expression reduced feeding as well as water ingestion due to a drastic decrease in the gustatory sensillar sensitivity for all tested tastants. These results indicate that Desi helps protect insects from desiccation damage by not only preventing dehydration through the integument but also accelerating water ingestion via elevated taste sensitivities of the sensilla.

  10. Contrast masking in strabismic amblyopia: attenuation, noise, interocular suppression and binocular summation.

    PubMed

    Baker, Daniel H; Meese, Tim S; Hess, Robert F

    2008-07-01

    To investigate amblyopic contrast vision at threshold and above we performed pedestal-masking (contrast discrimination) experiments with a group of eight strabismic amblyopes using horizontal sinusoidal gratings (mainly 3c/deg) in monocular, binocular and dichoptic configurations balanced across eye (i.e. five conditions). With some exceptions in some observers, the four main results were as follows. (1) For the monocular and dichoptic conditions, sensitivity was less in the amblyopic eye than in the good eye at all mask contrasts. (2) Binocular and monocular dipper functions superimposed in the good eye. (3) Monocular masking functions had a normal dipper shape in the good eye, but facilitation was diminished in the amblyopic eye. (4) A less consistent result was normal facilitation in dichoptic masking when testing the good eye, but a loss of this when testing the amblyopic eye. This pattern of amblyopic results was replicated in a normal observer by placing a neutral density filter in front of one eye. The two-stage model of binocular contrast gain control [Meese, T.S., Georgeson, M.A. & Baker, D.H. (2006). Binocular contrast vision at and above threshold. Journal of Vision 6, 1224-1243.] was 'lesioned' in several ways to assess the form of the amblyopic deficit. The most successful model involves attenuation of signal and an increase in noise in the amblyopic eye, and intact stages of interocular suppression and binocular summation. This implies a behavioural influence from monocular noise in the amblyopic visual system as well as in normal observers with an ND filter over one eye.

  11. A Sensitive Dynamic and Active Pixel Vision Sensor for Color or Neural Imaging Applications.

    PubMed

    Moeys, Diederik Paul; Corradi, Federico; Li, Chenghan; Bamford, Simeon A; Longinotti, Luca; Voigt, Fabian F; Berry, Stewart; Taverni, Gemma; Helmchen, Fritjof; Delbruck, Tobi

    2018-02-01

    Applications requiring detection of small visual contrast require high sensitivity. Event cameras can provide higher dynamic range (DR) and reduce data rate and latency, but most existing event cameras have limited sensitivity. This paper presents the results of a 180-nm Towerjazz CIS process vision sensor called SDAVIS192. It outputs temporal contrast dynamic vision sensor (DVS) events and conventional active pixel sensor frames. The SDAVIS192 improves on previous DAVIS sensors with higher sensitivity for temporal contrast. The temporal contrast thresholds can be set down to 1% for negative changes in logarithmic intensity (OFF events) and down to 3.5% for positive changes (ON events). The achievement is possible through the adoption of an in-pixel preamplification stage. This preamplifier reduces the effective intrascene DR of the sensor (70 dB for OFF and 50 dB for ON), but an automated operating region control allows up to at least 110-dB DR for OFF events. A second contribution of this paper is the development of characterization methodology for measuring DVS event detection thresholds by incorporating a measure of signal-to-noise ratio (SNR). At average SNR of 30 dB, the DVS temporal contrast threshold fixed pattern noise is measured to be 0.3%-0.8% temporal contrast. Results comparing monochrome and RGBW color filter array DVS events are presented. The higher sensitivity of SDAVIS192 make this sensor potentially useful for calcium imaging, as shown in a recording from cultured neurons expressing calcium sensitive green fluorescent protein GCaMP6f.

  12. Investigating biofilm structure using x-ray microtomography and gratings-based phase contrast

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, Erin A.; Xiao, Xianghui; Miller, Micah D.

    2012-10-17

    Direct examination of natural and engineered environments has revealed that the majority of microorganisms in these systems live in structured communities termed biofilms. To gain a better understanding for how biofilms function and interact with their local environment, fundamental capabilities for enhanced visualization, compositional analysis, and functional characterization of biofilms are needed. For pore-scale and community-scale analysis (100’s of nm to 10’s of microns), a variety of surface tools are available. However, understanding biofilm structure in complex three-dimensional (3-D) environments is considerably more difficult. X-ray microtomography can reveal a biofilm’s internal structure, but the obtaining sufficient contrast to image low-Zmore » biological material against a higher-Z substrate makes detecting biofilms difficult. Here we present results imaging Shewanella oneidensis biofilms on a Hollow-fiber Membrane Biofilm Reactor (HfMBR), using the x-ray microtomography system at sector 2-BM of the Advanced Photon Source (APS), at energies ranging from 13-15.4 keV and pixel sizes of 0.7 and 1.3 μm/pixel. We examine the use of osmium (Os) as a contrast agent to enhance biofilm visibility and demonstrate that staining improves imaging of hydrated biofilms. We also present results using a Talbot interferometer to provide phase and scatter contrast information in addition to absorption. Talbot interferometry allows imaging of unstained hydrated biofilms with phase contrast, while absorption contrast primarily highlights edges and scatter contrast provides little information. However, the gratings used here limit the spatial resolution to no finer than 2 μm, which hinders the ability to detect small features. Future studies at higher resolution or higher Talbot order for greater sensitivity to density variations may improve imaging.« less

  13. Novel frontiers in ultra-structural and molecular MRI of the brain.

    PubMed

    Duyn, Jeff H; Koretsky, Alan P

    2011-08-01

    Recent developments in the MRI of the brain continue to expand its use in basic and clinical neuroscience. This review highlights some areas of recent progress. Higher magnetic field strengths and improved signal detectors have allowed improved visualization of the various properties of the brain, facilitating the anatomical definition of function-specific areas and their connections. For example, by sensitizing the MRI signal to the magnetic susceptibility of tissue, it is starting to become possible to reveal the laminar structure of the cortex and identify millimeter-scale fiber bundles. Using exogenous contrast agents, and innovative ways to manipulate contrast, it is becoming possible to highlight specific fiber tracts and cell populations. These techniques are bringing us closer to understanding the evolutionary blueprint of the brain, improving the detection and characterization of disease, and help to guide treatment. Recent MRI techniques are leading to more detailed and more specific contrast in the study of the brain.

  14. A common-path optical coherence tomography based electrode for structural imaging of nerves and recording of action potentials

    NASA Astrophysics Data System (ADS)

    Islam, M. Shahidul; Haque, Md. Rezuanul; Oh, Christian M.; Wang, Yan; Park, B. Hyle

    2013-03-01

    Current technologies for monitoring neural activity either use different variety of electrodes (electrical recording) or require contrast agents introduced exogenously or through genetic modification (optical imaging). Here we demonstrate an optical method for non-contact and contrast agent free detection of nerve activity using phase-resolved optical coherence tomography (pr-OCT). A common-path variation of the pr-OCT is recently implemented and the developed system demonstrated the capability to detect rapid transient structural changes that accompany neural spike propagation. No averaging over multiple trials was required, indicating its capability of single-shot detection of individual impulses from functionally stimulated Limulus optic nerve. The strength of this OCT-based optical electrode is that it is a contactless method and does not require any exogenous contrast agent. With further improvements in accuracy and sensitivity, this optical electrode will play a complementary role to the existing recording technologies in future.

  15. Resonant soft X-ray scattering on protein solutions

    NASA Astrophysics Data System (ADS)

    Ye, Dan; Le, Thinh; Wang, Cheng; Zwart, Peter; Gomez, Esther; Gomez, Enrique

    Protein structure is crucial for biological function, such that characterizing protein folding and packing is important for the design of therapeutics and enzymes. We propose resonant soft X-ray scattering (RSOXS) as an approach to study proteins and other biological assemblies in solution. Calculations of the scattering contrast suggest that soft X-ray scattering is more sensitive than hard X-ray scattering, because of contrast generated at the absorption edges of constituent elements such as carbon, nitrogen and oxygen. We have examined the structure of bovine serum albumin (BSA) in solution by RSOXS. We find that by varying incident X-ray energies, we are able to achieve higher scattering contrast near the absorption edge. From our RSOXS scattering result we are able to reconstruct the structure of BSA in 3D. These RSOXS results also agree with hard X-ray experiments, including crystallographic data. Our study demonstrates the potential of RSOXS for studying protein structure in solution.

  16. Transcranial functional ultrasound imaging of the brain using microbubble-enhanced ultrasensitive Doppler

    PubMed Central

    Errico, Claudia; Osmanski, Bruno-Félix; Pezet, Sophie; Couture, Olivier; Lenkei, Zsolt; Tanter, Mickael

    2016-01-01

    Functional ultrasound (fUS) is a novel neuroimaging technique, based on high-sensitivity ultrafast Doppler imaging of cerebral blood volume, capable of measuring brain activation and connectivity in rodents with high spatiotemporal resolution (100 μm, 1 ms). However, the skull attenuates acoustic waves, so fUS in rats currently requires craniotomy or a thinned-skull window. Here we propose a non-invasive approach by enhancing the fUS signal with a contrast agent, inert gas microbubbles. Plane-wave illumination of the brain at high frame rate (500 Hz compounded sequence with three tilted plane waves, PRF = 1500Hz with a 128 element 15 MHz linear transducer), yields highly-resolved neurovascular maps. We compared fUS imaging performance through the intact skull bone (transcranial fUS) versus a thinned-skull window in the same animal. First, we show that the vascular network of the adult rat brain can be imaged transcranially only after a bolus intravenous injection of microbubbles, which leads to a 9 dB gain in the contrast-to-tissue ratio. Next, we demonstrate that functional increase in the blood volume of the primary sensory cortex after targeted electrical-evoked stimulations of the sciatic nerve is observable transcranially in presence of contrast agents, with high reproducibility (Pearson's coefficient ρ = 0.7 ± 0.1, p = 0.85). Our work demonstrates that the combination of ultrafast Doppler imaging and injection of contrast agent allows non-invasive functional brain imaging through the intact skull bone in rats. These results should ease non-invasive longitudinal studies in rodents and open a promising perspective for the adoption of highly resolved fUS approaches for the adult human brain. PMID:26416649

  17. Accurate and quantitative polarization-sensitive OCT by unbiased birefringence estimator with noise-stochastic correction

    NASA Astrophysics Data System (ADS)

    Kasaragod, Deepa; Sugiyama, Satoshi; Ikuno, Yasushi; Alonso-Caneiro, David; Yamanari, Masahiro; Fukuda, Shinichi; Oshika, Tetsuro; Hong, Young-Joo; Li, En; Makita, Shuichi; Miura, Masahiro; Yasuno, Yoshiaki

    2016-03-01

    Polarization sensitive optical coherence tomography (PS-OCT) is a functional extension of OCT that contrasts the polarization properties of tissues. It has been applied to ophthalmology, cardiology, etc. Proper quantitative imaging is required for a widespread clinical utility. However, the conventional method of averaging to improve the signal to noise ratio (SNR) and the contrast of the phase retardation (or birefringence) images introduce a noise bias offset from the true value. This bias reduces the effectiveness of birefringence contrast for a quantitative study. Although coherent averaging of Jones matrix tomography has been widely utilized and has improved the image quality, the fundamental limitation of nonlinear dependency of phase retardation and birefringence to the SNR was not overcome. So the birefringence obtained by PS-OCT was still not accurate for a quantitative imaging. The nonlinear effect of SNR to phase retardation and birefringence measurement was previously formulated in detail for a Jones matrix OCT (JM-OCT) [1]. Based on this, we had developed a maximum a-posteriori (MAP) estimator and quantitative birefringence imaging was demonstrated [2]. However, this first version of estimator had a theoretical shortcoming. It did not take into account the stochastic nature of SNR of OCT signal. In this paper, we present an improved version of the MAP estimator which takes into account the stochastic property of SNR. This estimator uses a probability distribution function (PDF) of true local retardation, which is proportional to birefringence, under a specific set of measurements of the birefringence and SNR. The PDF was pre-computed by a Monte-Carlo (MC) simulation based on the mathematical model of JM-OCT before the measurement. A comparison between this new MAP estimator, our previous MAP estimator [2], and the standard mean estimator is presented. The comparisons are performed both by numerical simulation and in vivo measurements of anterior and posterior eye segment as well as in skin imaging. The new estimator shows superior performance and also shows clearer image contrast.

  18. DISTINCT FUNCTIONS OF JNK AND C-JUN IN OXIDANT-INDUCED HEPATOCYTE DEATH

    PubMed Central

    Amir, Muhammad; Liu, Kun; Zhao, Enpeng; Czaja, Mark J.

    2013-01-01

    Overactivation of c-Jun N-terminal kinase (JNK)/c-Jun signaling is a central mechanism of hepatocyte injury and death including that from oxidative stress. However, the functions of JNK and c-Jun are still unclear, and this pathway also inhibits hepatocyte death. Previous studies of menadione-induced oxidant stress demonstrated that toxicity resulted from sustained JNK/c-Jun activation as death was blocked by the c-Jun dominant negative TAM67. To further delineate the function of JNK/c-Jun signaling in hepatocyte injury from oxidant stress, the effects of direct JNK inhibition on menadione-induced death were examined. In contrast to the inhibitory effect of TAM67, pharmacological JNK inhibition by SP600125 sensitized the rat hepatocyte cell line RALA255-10G to death from menadione. SP600125 similarly sensitized mouse primary hepatocytes to menadione toxicity. Death from SP600125/menadione was c-Jun dependent as it was blocked by TAM67, but independent of c-Jun phosphorylation. Death occurred by apoptosis and necrosis and activation of the mitochondrial death pathway. Short hairpin RNA knockdowns of total JNK or JNK2 sensitized to death from menadione, whereas a jnk1 knockdown was protective. Jnk2 null mouse primary hepatocytes were also sensitized to menadione death. JNK inhibition magnified decreases in cellular ATP content and β-oxidation induced by menadione. This effect mediated cell death as chemical inhibition of β-oxidation also sensitized cells to death from menadione, and supplementation with the β-oxidation substrate oleate blocked death. Components of the JNK/c-Jun signaling pathway have opposing functions in hepatocyte oxidant stress with JNK2 mediating resistance to cell death and c-Jun promoting death. PMID:22644775

  19. Penetrating Colorectal Injuries: Diagnostic Performance of Multidetector CT with Trajectography.

    PubMed

    Dreizin, David; Boscak, Alexis R; Anstadt, Michael J; Tirada, Nikki; Chiu, William C; Munera, Felipe; Bodanapally, Uttam K; Hornick, Michael; Stein, Deborah M

    2016-12-01

    Purpose To determine the diagnostic performance of multidetector computed tomography (CT) with trajectography for penetrating colorectal injuries. Materials and Methods This institutional review board-approved and HIPAA-compliant study was a 6-year blinded retrospective review by two independent readers of 182 consecutive patients who preoperatively underwent 40- or 64-row multidetector CT for penetrating torso trauma below the diaphragm and had surgically confirmed findings. Colorectal perforation was present in 42 patients. Trajectory analysis with postprocessing software was used for all studies. Additional signs evaluated were rectal contrast agent leak, collections of extruded fecal material, mural defect, wall thickening, abnormal enhancement, free fluid or stranding, and free air. The quality of the colorectal contrast agent administration was recorded. Sensitivity, specificity, predictive values, areas under the receiver operating characteristic curves (AUCs), and Cohen κ were determined. Results In patients with rectal contrast agent administration (n = 151), AUCs were 0.90-0.91, which indicated excellent accuracy. Trajectory was sensitive (88%-91%). For single wounds (n = 104), sensitivity of trajectory was 96% for both readers, but was only 80% for multiple wounds (n = 47). Contrast agent leak was highly specific (96%-98%), but insensitive (42%-46%). Improved diagnostic performance was observed in patients with poor colonic distension or opacification. Accuracy remained high (AUC, 0.86-0.99) in the group without rectal contrast agent administration (n = 31). Conclusion Trajectory had excellent sensitivity, while rectal contrast agent leak was specific but insensitive. Sensitivity of trajectory was lower for multiple wounds. Accuracy remained high in patients without rectal contrast agent administration. © RSNA, 2016.

  20. Sensitivity of fructose-1,6-biphosphatase from yeast, liver and skeletal muscle to fructose-2,6-biphosphate and 5'-adenosine monophosphate.

    PubMed

    von Herrath, M; Holzer, H

    1988-05-01

    As a prerequisite for future studies on the possible effect of sulphite, an anti-microbial agent, on gluconeogenesis in yeast, a comparative study of fructose-1,6-bisphosphatase (FBPase), a key enzyme of gluconeogenesis, from yeast, liver and skeletal muscle is reported. In contrast to FBPase from yeast or liver, FBPase from skeletal muscle is approximately 1000-fold more sensitive to inhibition by 5' adenosine monophosphate and 30 to 250-fold less sensitive to inhibition by fructose-2,6-bisphosphate. The kinetic properties of the FBPases, determined by the ratios R(Mg2+/Mn2+) and R (pH 7/9) of the enzyme activities, measured at 10 mM Mg2+ and 2 mM Mn2+ and at pH 7.0 and 9.0, respectively, show a drastic difference between the skeletal muscle and the yeast or liver enzymes. The data support the idea that the enzymes from yeast and liver function in gluconeogenesis, whereas the enzyme from skeletal muscle is involved in other biological functions.

  1. River ecosystem processes: A synthesis of approaches, criteria of use and sensitivity to environmental stressors.

    PubMed

    von Schiller, Daniel; Acuña, Vicenç; Aristi, Ibon; Arroita, Maite; Basaguren, Ana; Bellin, Alberto; Boyero, Luz; Butturini, Andrea; Ginebreda, Antoni; Kalogianni, Eleni; Larrañaga, Aitor; Majone, Bruno; Martínez, Aingeru; Monroy, Silvia; Muñoz, Isabel; Paunović, Momir; Pereda, Olatz; Petrovic, Mira; Pozo, Jesús; Rodríguez-Mozaz, Sara; Rivas, Daniel; Sabater, Sergi; Sabater, Francesc; Skoulikidis, Nikolaos; Solagaistua, Libe; Vardakas, Leonidas; Elosegi, Arturo

    2017-10-15

    River ecosystems are subject to multiple stressors that affect their structure and functioning. Ecosystem structure refers to characteristics such as channel form, water quality or the composition of biological communities, whereas ecosystem functioning refers to processes such as metabolism, organic matter decomposition or secondary production. Structure and functioning respond in contrasting and complementary ways to environmental stressors. Moreover, assessing the response of ecosystem functioning to stressors is critical to understand the effects on the ecosystem services that produce direct benefits to humans. Yet, there is more information on structural than on functional parameters, and despite the many approaches available to measure river ecosystem processes, structural approaches are more widely used, especially in management. One reason for this discrepancy is the lack of synthetic studies analyzing river ecosystem functioning in a way that is useful for both scientists and managers. Here, we present a synthesis of key river ecosystem processes, which provides a description of the main characteristics of each process, including criteria guiding their measurement as well as their respective sensitivity to stressors. We also discuss the current limitations, potential improvements and future steps that the use of functional measures in rivers needs to face. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  2. Is Suppression Just Normal Dichoptic Masking? Suprathreshold Considerations.

    PubMed

    Reynaud, Alexandre; Hess, Robert F

    2016-10-01

    Amblyopic patients have a deficit in visual acuity and contrast sensitivity in their amblyopic eye as well as suppression of the amblyopic eye input under binocular viewing conditions. In this study we wanted to assess the origin of the amblyopic suppression by studying the contrast perception of the amblyopic eye at suprathreshold levels under binocular and monocular viewing. Using a suprathreshold contrast matching task in which the reference and target stimuli were presented to different eyes either simultaneously or successively, we measured interocular contrast matching in 10 controls and 11 amblyopes (mean age 35 ± 15; 5 strabismics; 3 anisometropes; 3 mixed). This was then used as an index of the binocular balance across spatial frequency and compared against the contrast sensitivity ratio measured with the same stimuli. We observed that binocular matching becomes more imbalanced at high spatial frequency for amblyopes, compared with controls; that this imbalance did not depend in either group on whether the stimuli were presented simultaneously or successively; and that for both modes of presentation the matching balance correlates well with the interocular contrast sensitivity ratio (mean correlation coefficient of the slopes R = 0.7125). The results from our amblyopes show comparable losses of contrast perception at and above threshold under these binocular viewing conditions across a wide spatial frequency range, much stronger than that observed for our controls. This occurs under conditions in which there should be no dichoptic masking. Furthermore, the matching contrast could be well predicted by the monocular contrast sensitivity. Altogether, this suggests that amblyopic suppression cannot be explained by normal dichoptic masking but rather an attenuation of the input.

  3. Visual resolution and contrast sensitivity in two benthic sharks.

    PubMed

    Ryan, Laura A; Hart, Nathan S; Collin, Shaun P; Hemmi, Jan M

    2016-12-15

    Sharks have long been described as having 'poor' vision. They are cone monochromats and anatomical estimates suggest they have low spatial resolution. However, there are no direct behavioural measurements of spatial resolution or contrast sensitivity. This study estimates contrast sensitivity and spatial resolution of two species of benthic sharks, the Port Jackson shark, Heterodontus portusjacksoni, and the brown-banded bamboo shark, Chiloscyllium punctatum, by recording eye movements in response to optokinetic stimuli. Both species tracked moving low spatial frequency gratings with weak but consistent eye movements. Eye movements ceased at 0.38 cycles per degree, even for high contrasts, suggesting low spatial resolution. However, at lower spatial frequencies, eye movements were elicited by low contrast gratings, 1.3% and 2.9% contrast in H portusjacksoni and C. punctatum, respectively. Contrast sensitivity was higher than in other vertebrates with a similar spatial resolving power, which may reflect an adaptation to the relatively low contrast encountered in aquatic environments. Optokinetic gain was consistently low and neither species stabilised the gratings on their retina. To check whether restraining the animals affected their optokinetic responses, we also analysed eye movements in free-swimming C. punctatum We found no eye movements that could compensate for body rotations, suggesting that vision may pass through phases of stabilisation and blur during swimming. As C. punctatum is a sedentary benthic species, gaze stabilisation during swimming may not be essential. Our results suggest that vision in sharks is not 'poor' as previously suggested, but optimised for contrast detection rather than spatial resolution. © 2016. Published by The Company of Biologists Ltd.

  4. Comparison of the visual and intraocular optical performance of a refractive multifocal IOL with rotational asymmetry and an apodized diffractive multifocal IOL.

    PubMed

    Alió, Jorge L; Plaza-Puche, Ana B; Javaloy, Jaime; Ayala, María José

    2012-02-01

    To compare the visual outcomes and intraocular optical quality observed postoperatively in patients implanted with a rotationally asymmetric multifocal intraocular lens (IOL) and an apodized diffractive multifocal IOL. Seventy-four consecutive eyes of 40 cataract patients (age range: 36 to 79 years) were divided into two groups: zonal refractive group, 39 eyes implanted with a rotationally asymmetric multifocal IOL (Lentis Mplus LS-312 IOL, Oculentis GmbH); and diffractive group, 35 eyes implanted with an apodized diffractive multifocal IOL (ReSTOR SN6AD3, Alcon Laboratories Inc). Distance and near visual acuity outcomes, contrast sensitivity, intraocular optical quality, and defocus curves were evaluated during 3-month follow-up. Calculation of the intraocular aberrations was performed by subtracting corneal aberrations from total ocular aberrations. Uncorrected near visual acuity and distance-corrected near visual acuity were better in the diffractive group than in the zonal refractive group (P=.01), whereas intermediate visual acuity (defocus +1.00 and +1.50 diopters) was better in the zonal refractive group. Photopic contrast sensitivity was significantly better in the zonal refractive group (P=.04). Wavefront aberrations (total, higher order, tilt, primary coma) were significantly higher in the zonal refractive group than in the diffractive group (P=.02). Both multifocal IOLs are able to successfully restore visual function after cataract surgery. The zonal refractive multifocal IOL provides better results in contrast sensitivity and intermediate vision, whereas the diffractive multifocal IOL provides better near vision at a closer distance. Copyright 2012, SLACK Incorporated.

  5. Retinal Layer Abnormalities as Biomarkers of Schizophrenia.

    PubMed

    Samani, Niraj N; Proudlock, Frank A; Siram, Vasantha; Suraweera, Chathurie; Hutchinson, Claire; Nelson, Christopher P; Al-Uzri, Mohammed; Gottlob, Irene

    2018-06-06

    Schizophrenia is associated with several brain deficits, as well as visual processing deficits, but clinically useful biomarkers are elusive. We hypothesized that retinal layer changes, noninvasively visualized using spectral-domain optical coherence tomography (SD-OCT), may represent a possible "window" to these abnormalities. A Leica EnvisuTM SD-OCT device was used to obtain high-resolution central foveal B-scans in both eyes of 35 patients with schizophrenia and 50 demographically matched controls. Manual retinal layer segmentation was performed to acquire individual and combined layer thickness measurements in 3 macular regions. Contrast sensitivity was measured at 3 spatial frequencies in a subgroup of each cohort. Differences were compared using adjusted linear models and significantly different layer measures in patients underwent Spearman Rank correlations with contrast sensitivity, quantified symptoms severity, disease duration, and antipsychotic medication dose. Total retinal and photoreceptor complex thickness was reduced in all regions in patients (P < .0001). Segmentation revealed consistent thinning of the outer nuclear layer (P < .001) and inner segment layer (P < .05), as well as a pattern of parafoveal ganglion cell changes. Low spatial frequency contrast sensitivity was reduced in patients (P = .002) and correlated with temporal parafoveal ganglion cell complex thinning (R = .48, P = .01). Negative symptom severity was inversely correlated with foveal photoreceptor complex thickness (R = -.54, P = .001) and outer nuclear layer thickness (R = -.47, P = .005). Our novel findings demonstrate considerable retinal layer abnormalities in schizophrenia that are related to clinical features and visual function. With time, SD-OCT could provide easily-measurable biomarkers to facilitate clinical assessment and further our understanding of the disease.

  6. Driving under low-contrast visibility conditions in Parkinson disease

    PubMed Central

    Uc, E Y.; Rizzo, M; Anderson, S W.; Dastrup, E; Sparks, J D.; Dawson, J D.

    2009-01-01

    Objective: To assess driving performance in Parkinson disease (PD) under low-contrast visibility conditions. Methods: Licensed, active drivers with mild to moderate PD (n = 67, aged 66.2 ± 9.0 years, median Hoehn–Yahr stage = 2) and controls (n = 51, aged 64.0 ± 7.2 years) drove in a driving simulator under high- (clear sky) and low-contrast visibility (fog) conditions, leading up to an intersection where an incurring vehicle posed a crash risk in fog. Results: Drivers with PD had higher SD of lateral position (SDLP) and lane violation counts (LVC) than controls during fog (p < 0.001). Transition from high- to low-contrast visibility condition increased SDLP and LVC more in PD than in controls (p < 0.01). A larger proportion of drivers with PD crashed at the intersection in fog (76.1% vs 37.3%, p < 0.0001). The time to first reaction in response to incursion was longer in drivers with PD compared with controls (median 2.5 vs 2.0 seconds, p < 0.0001). Within the PD group, the strongest predictors of poor driving outcomes under low-contrast visibility conditions were worse scores on measures of visual processing speed and attention, motion perception, contrast sensitivity, visuospatial construction, motor speed, and activities of daily living score. Conclusions: During driving simulation under low-contrast visibility conditions, drivers with Parkinson disease (PD) had poorer vehicle control and were at higher risk for crashes, which were primarily predicted by decreased visual perception and cognition; motor dysfunction also contributed. Our results suggest that drivers with PD may be at risk for unsafe driving in low-contrast visibility conditions such as during fog or twilight. GLOSSARY ADL = activities of daily living; CFT = Complex Figure Test; CS = contrast sensitivity; FOV = field of view; FR = functional reach; FVA = far visual acuity; JLO = judgment of line orientation; LVC = lane violation counts; PD = Parkinson disease; SDLP = SD of lateral position; SFM = structure from motion; SIREN = Simulator for Interdisciplinary Research in Ergonomics and Neuroscience; TFR = time to first reaction; UFOV = useful field of view; UPDRS = Unified Parkinson’s Disease Rating Scale. PMID:19805726

  7. Brightness discrimination and contrast sensitivity in chronic glaucoma--a clinical study.

    PubMed

    Teoh, S L; Allan, D; Dutton, G N; Foulds, W S

    1990-04-01

    The visual acuity, the difference in sensitivity of the two eyes to light (brightness ratio), and contrast sensitivity were assessed in 28 patients with chronic open angle glaucoma and compared with those of 41 normal controls of similar ages and visual acuity. The results obtained were related to the results of Tübingen visual field analysis in patients with glaucoma. Twenty-four of the 28 glaucoma patients (86%) had a significant disparity in brightness ratio between the two eyes. This was found to match the frequency of visual field loss. Moreover, there was a significant relationship between the interocular differences in brightness sense and the difference in the degree of visual field loss between the two eyes. Of the glaucoma patients 39% had sum contrast sensitivities outside the normal range for age-matched normal controls. No significant correlation was found between the interocular difference in brightness sense and the visual acuity or the interocular difference in sum contrast sensitivity. It is concluded that, in the presence of a normal visual acuity, the brightness ratio test warrants evaluation as a potential screening test for chronic open angle glaucoma.

  8. The effects of longitudinal chromatic aberration and a shift in the peak of the middle-wavelength sensitive cone fundamental on cone contrast

    PubMed Central

    Rucker, F. J.; Osorio, D.

    2009-01-01

    Longitudinal chromatic aberration is a well-known imperfection of visual optics, but the consequences in natural conditions, and for the evolution of receptor spectral sensitivities are less well understood. This paper examines how chromatic aberration affects image quality in the middle-wavelength sensitive (M-) cones, viewing broad-band spectra, over a range of spatial frequencies and focal planes. We also model the effects on M-cone contrast of moving the M-cone fundamental relative to the long- and middle-wavelength (L- and M-cone) fundamentals, while the eye is accommodated at different focal planes or at a focal plane that maximizes luminance contrast. When the focal plane shifts towards longer (650 nm) or shorter wavelengths (420 nm) the effects on M-cone contrast are large: longitudinal chromatic aberration causes total loss of M-cone contrast above 10 to 20 c/d. In comparison, the shift of the M-cone fundamental causes smaller effects on M-cone contrast. At 10 c/d a shift in the peak of the M-cone spectrum from 560 nm to 460 nm decreases M-cone contrast by 30%, while a 10 nm blue-shift causes only a minor loss of contrast. However, a noticeable loss of contrast may be seen if the eye is focused at focal planes other than that which maximizes luminance contrast. The presence of separate long- and middle-wavelength sensitive cones therefore has a small, but not insignificant cost to the retinal image via longitudinal chromatic aberration. This aberration may therefore be a factor limiting evolution of visual pigments and trichromatic color vision. PMID:18639571

  9. Diagnostic accuracy of contrast-enhanced computed tomography and contrast-enhanced magnetic resonance imaging of small renal masses in real practice: sensitivity and specificity according to subjective radiologic interpretation.

    PubMed

    Kim, Jae Heon; Sun, Hwa Yeon; Hwang, Jiyoung; Hong, Seong Sook; Cho, Yong Jin; Doo, Seung Whan; Yang, Won Jae; Song, Yun Seob

    2016-10-12

    The aim of this study was to investigate the diagnostic accuracy of contrast-enhanced computed tomography (CT) and contrast-enhanced magnetic resonance imaging (MRI) of small renal masses in real practice. Contrast-enhanced CT and MRI were performed between February 2008 and February 2013 on 68 patients who had suspected small (≤4 cm) renal cell carcinoma (RCC) based on ultrasonographic measurements. CT and MRI radiographs were reviewed, and the findings of small renal masses were re-categorized into five dichotomized scales by the same two radiologists who had interpreted the original images. Receiver operating characteristics curve analysis was performed, and sensitivity and specificity were determined. Among the 68 patients, 60 (88.2 %) had RCC and eight had benign disease. The diagnostic accuracy rates of contrast-enhanced CT and MRI were 79.41 and 88.23 %, respectively. Diagnostic accuracy was greater when using contrast-enhanced MRI because too many masses (67.6 %) were characterized as "4 (probably solid cancer) or 5 (definitely solid cancer)." The sensitivity of contrast-enhanced CT and MRI for predicting RCC were 79.7 and 88.1 %, respectively. The specificities of contrast-enhanced CT and MRI for predicting RCC were 44.4 and 33.3 %, respectively. Fourteen diagnoses (20.5 %) were missed or inconsistent compared with the final pathological diagnoses. One appropriate nephroureterectomy and five unnecessary percutaneous biopsies were performed for RCC. Seven unnecessary partial nephrectomies were performed for benign disease. Although contrast-enhanced CT and MRI showed high sensitivity for detecting small renal masses, specificity remained low.

  10. Semipermeable Hollow Fiber Phantoms for Development and Validation of Perfusion-Sensitive MR Methods and Signal Models

    PubMed Central

    Anderson, J.R.; Ackerman, J.J.H.; Garbow, J.R.

    2015-01-01

    Two semipermeable, hollow fiber phantoms for the validation of perfusion-sensitive magnetic resonance methods and signal models are described. Semipermeable hollow fibers harvested from a standard commercial hemodialysis cartridge serve to mimic tissue capillary function. Flow of aqueous media through the fiber lumen is achieved with a laboratory-grade peristaltic pump. Diffusion of water and solute species (e.g., Gd-based contrast agent) occurs across the fiber wall, allowing exchange between the lumen and the extralumenal space. Phantom design attributes include: i) small physical size, ii) easy and low-cost construction, iii) definable compartment volumes, and iv) experimental control over media content and flow rate. PMID:26167136

  11. Structure and function in patients with glaucomatous defects near fixation.

    PubMed

    Shafi, Asifa; Swanson, William H; Dul, Mitchell W

    2011-01-01

    To assess relations between perimetric sensitivity and neuroretinal rim area using high-resolution perimetric mapping in patients with glaucomatous defects within 10° of fixation. One eye was tested in each of 31 patients with open-angle glaucoma enrolled in a prospective study of perimetric defects within 10° of fixation. Norms were derived from 110 control subjects free of eye disease, aged 21 to 81 years. Perimetric sensitivity was measured using the 10-2 test pattern with the Swedish Interactive Threshold Algorithm (SITA) standard algorithm on the Humphrey Field Analyzer (HFA) II-i; Carl Zeiss Meditec), stimulus size III. Area of the temporal neuroretinal rim was measured using the Heidelberg retina tomograph 3. Decibel values were converted into linear units of contrast sensitivity averaged across locations corresponding to the temporal rim sector. Both measures were expressed as percent of mean normal, and the Bland-Altman method was used to assess agreement. Perimetric locations corresponding to the temporal sector were determined for six different optic nerve maps. Contrast sensitivity was moderately correlated with temporal rim area (r2 >30%, p < 0.005). For all six optic nerve maps, Bland-Altman analysis found good agreement between perimetric sensitivity and rim area with both measures expressed as fraction of mean normal and confidence limits for agreement that were consistent with normal between-subject variability in control eyes. By using high-resolution perimetric mapping in patients with scotomas within 10° of fixation, we confirmed findings of linear relations between perimetric sensitivity and area of temporal neuroretinal rim and showed that the confidence limits for agreement in patients with glaucoma were consistent with normal between-subject variability.

  12. Structure and Function in Patients with Glaucomatous Defects Near Fixation

    PubMed Central

    Shafi, Asifa; Swanson, William H.; Dul, Mitchell W.

    2010-01-01

    Purpose To assess relations between perimetric sensitivity and neuroretinal rim area using high-resolution perimetric mapping in patients with glaucomatous defects within 10 degrees of fixation. Methods One eye was tested in each of 31 patients with open angle glaucoma enrolled in a prospective study of perimetric defects within 10 degrees of fixation. Norms were derived from 110 control subjects free of eye disease ages 21 – 81. Perimetric sensitivity was measured using the 10-2 test pattern with the SITA Standard algorithm (HFAII-i, Carl Zeiss Meditec), stimulus size III. Area of the temporal neuroretinal rim was measured using the Heidelberg Retinal Tomograph (HRT III). Decibel (dB) values were converted into linear units of contrast sensitivity averaged across locations corresponding to the temporal rim sector. Both measures were expressed as percent of mean normal and the Bland-Altman method was used to assess agreement. Perimetric locations corresponding to the temporal sector were determined for six different optic nerve maps. Results Contrast sensitivity was moderately correlated with temporal rim area (r2 > 30%, p < 0.005). For all six optic nerve maps, Bland-Altman analysis found good agreement between perimetric sensitivity and rim area with both measures expressed as fraction of mean normal, and confidence limits for agreement that were consistent with normal between-subject variability in control eyes. Conclusions Using high-resolution perimetric mapping in patients with scotomas within 10° of fixation, we confirmed findings of linear relations between perimetric sensitivity and area of temporal neuroretinal rim, and showed that the confidence limits for agreement in patients with glaucoma were consistent with normal between-subject variability. PMID:20935585

  13. Comparison of a new refractive multifocal intraocular lens with an inferior segmental near add and a diffractive multifocal intraocular lens.

    PubMed

    Alio, Jorge L; Plaza-Puche, Ana B; Javaloy, Jaime; Ayala, María José; Moreno, Luis J; Piñero, David P

    2012-03-01

    To compare the visual acuity outcomes and ocular optical performance of eyes implanted with a multifocal refractive intraocular lens (IOL) with an inferior segmental near add or a diffractive multifocal IOL. Prospective, comparative, nonrandomized, consecutive case series. Eighty-three consecutive eyes of 45 patients (age range, 36-82 years) with cataract were divided into 2 groups: group A, 45 eyes implanted with Lentis Mplus LS-312 (Oculentis GmbH, Berlin, Germany); group B, 38 eyes implanted with diffractive IOL Acri.Lisa 366D (Zeiss, Oberkochen, Germany). All patients underwent phacoemulsification followed by IOL implantation in the capsular bag. Distance corrected, intermediate, and near with the distance correction visual acuity outcomes and contrast sensitivity, intraocular aberrations, and defocus curve were evaluated postoperatively during a 3-month follow-up. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), corrected distance near and intermediate visual acuity (CDNVA), contrast sensitivity, intraocular aberrations, and defocus curve. A significant improvement in UDVA, CDVA, and UNVA was observed in both groups after surgery (P ≤ 0.04). Significantly better values of UNVA (P<0.01) and CDNVA (P<0.04) were found in group B. In the defocus curve, significantly better visual acuities were present in eyes in group A for intermediate vision levels of defocus (P ≤ 0.04). Significantly higher amounts of postoperative intraocular primary coma and spherical aberrations were found in group A (P<0.01). In addition, significantly better values were observed in photopic contrast sensitivity for high spatial frequencies in group A (P ≤ 0.04). The Lentis Mplus LS-312 and Acri.Lisa 366D IOLs are able to successfully restore visual function after cataract surgery. The Lentis Mplus LS-312 provided better intermediate vision and contrast sensitivity outcomes than the Acri.Lisa 366D. However, the Acri.Lisa design provided better distance and near visual outcomes and intraocular optical performance parameters. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  14. Dichoptic training improves contrast sensitivity in adults with amblyopia.

    PubMed

    Li, Jinrong; Spiegel, Daniel P; Hess, Robert F; Chen, Zidong; Chan, Lily Y L; Deng, Daming; Yu, Minbin; Thompson, Benjamin

    2015-09-01

    Dichoptic training is designed to promote binocular vision in patients with amblyopia. Initial studies have found that the training effects transfer to both binocular (stereopsis) and monocular (recognition acuity) visual functions. The aim of this study was to assess whether dichoptic training effects also transfer to contrast sensitivity (CS) in adults with amblyopia. We analyzed CS data from 30 adults who had taken part in one of two previous dichoptic training studies and assessed whether the changes in CS exceeded the 95% confidence intervals for change based on test-retest data from a separate group of observers with amblyopia. CS was measured using Gabor patches (0.5, 3 and 10cpd) before and after 10days of dichoptic training. Training was delivered using a dichoptic video game viewed through video goggles (n=15) or on an iPod touch equipped with a lenticular overlay screen (n=15). In the iPod touch study, training was combined with anodal transcranial direct current stimulation of the visual cortex. We found that dichoptic training significantly improved CS across all spatial frequencies tested for both groups. These results suggest that dichoptic training modifies the sensitivity of the neural systems that underpin monocular CS. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Design of ultrasonically-activatable nanoparticles using low boiling point perfluorocarbons.

    PubMed

    Sheeran, Paul S; Luois, Samantha H; Mullin, Lee B; Matsunaga, Terry O; Dayton, Paul A

    2012-04-01

    Recently, an interest has developed in designing biomaterials for medical ultrasonics that can provide the acoustic activity of microbubbles, but with improved stability in vivo and a smaller size distribution for extravascular interrogation. One proposed alternative is the phase-change contrast agent. Phase-change contrast agents (PCCAs) consist of perfluorocarbons (PFCs) that are initially in liquid form, but can then be vaporized with acoustic energy. Crucial parameters for PCCAs include their sensitivity to acoustic energy, their size distribution, and their stability, and this manuscript provides insight into the custom design of PCCAs for balancing these parameters. Specifically, the relationship between size, thermal stability and sensitivity to ultrasound as a function of PFC boiling point and ambient temperature is illustrated. Emulsion stability and sensitivity can be 'tuned' by mixing PFCs in the gaseous state prior to condensation. Novel observations illustrate that stable droplets can be generated from PFCs with extremely low boiling points, such as octafluoropropane (b.p. -36.7 °C), which can be vaporized with acoustic parameters lower than previously observed. Results demonstrate the potential for low boiling point PFCs as a useful new class of compounds for activatable agents, which can be tailored to the desired application. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Spatial contrast sensitivity - Effects of age, test-retest, and psychophysical method

    NASA Technical Reports Server (NTRS)

    Higgins, Kent E.; Jaffe, Myles J.; Caruso, Rafael C.; Demonasterio, Francisco M.

    1988-01-01

    Two different psychophysical methods were used to test the spatial contrast sensitivity in normal subjects from five age groups. The method of adjustment showed a decline in sensitivity with increasing age at all spatial frequencies, while the forced-choice procedure showed an age-related decline predominantly at high spatial frequencies. It is suggested that a neural component is responsible for this decline.

  17. An Imaging Biomarker for Assessing Hepatic Function in Patients with Primary Sclerosing Cholangitis.

    PubMed

    Schulze, Jennifer; Lenzen, Henrike; Hinrichs, Jan B; Ringe, Burckhardt; Manns, Michael P; Wacker, Frank; Ringe, Kristina I

    2018-05-15

    We aimed to evaluate the potential of hepatobiliary phase magnetic resonance imaging (MRI) as parameter for assessment of hepatocellular function in patients with primary sclerosing cholangitis (PSC). We collected data from 111 patients (83 male, 28 female; median, 44 years old), from March 2012 through March 2016, with a confirmed diagnosis of PSC who underwent MRI evaluation before and after injection (hepatobiliary phase) of a hepatocyte-specific contrast agent (gadoxetate disodium). Signal intensities were measured in each liver segment. Mean relative enhancement values were calculated and correlated with findings from liver functions tests, prognostic scoring systems (model for end-stage liver disease [MELD] score; Mayo risk score; Amsterdam-Oxford-PSC score), abnormalities detected by endoscopic retrograde cholangiopancreatography (using the Amsterdam cholangiographic classification system), and clinical endpoints (liver transplantation, cholangiocarcinoma, liver-related death). Our primary aim was to associate relative enhancement values with liver function and patient outcomes. Most patients had moderate-stage disease and had intermediate levels of risk (median MELD score, 8 and median Mayo score, 0.27). Clinical endpoints were reached by 21 patients (6 developed cholangiocarcinoma, 8 underwent liver transplantation, and 7 patients died). The highest levels of correlations were observed for relative enhancement 20 min after contrast injection and level of alkaline phosphatase (r= -0.636), bilirubin (r= -0.646), albumin (r= 0.538); as well as international normalized ratio (r=0.456); MELD score (r= -0.587); Mayo risk score (r= -0.535), and Amsterdam-Oxford model score (r= -0.595) (P<.0001). Relative enhancement correlated with all clinical endpoints (all P<.05). A cutoff relative enhancement value of 0.65 identified patients with a clinical endpoint with 73.9% sensitivity 92.9% specificity (area under the receiver operating characteristic curve, 0.901; likelihood ratio, 10.34; P<.0001). In an analysis of 111 patients with PSC, we found MRI-measured relative enhancement, using a hepatocyte-specific contrast agent, to identify patients with clinical outcomes with 73.9% sensitivity 92.9% specificity. Long-term, multicenter studies are needed to further evaluate this marker of PSC progression. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  18. Body temperature sensitive micelles for MRI enhancement.

    PubMed

    Zhu, Xiaolei; Chen, Shizhen; Luo, Qing; Ye, Chaohui; Liu, Maili; Zhou, Xin

    2015-06-04

    A novel thermo-sensitive micelle contrast agent and its enhancement of MRI contrast with temperature are reported. The morphology changes sharply near 37 °C, resulting in a significant amplification of the CEST signal. This enables detection of small changes in body temperature.

  19. Improved sensitivity of computed tomography towards iodine and gold nanoparticle contrast agents via iterative reconstruction methods

    PubMed Central

    Bernstein, Ally Leigh; Dhanantwari, Amar; Jurcova, Martina; Cheheltani, Rabee; Naha, Pratap Chandra; Ivanc, Thomas; Shefer, Efrat; Cormode, David Peter

    2016-01-01

    Computed tomography is a widely used medical imaging technique that has high spatial and temporal resolution. Its weakness is its low sensitivity towards contrast media. Iterative reconstruction techniques (ITER) have recently become available, which provide reduced image noise compared with traditional filtered back-projection methods (FBP), which may allow the sensitivity of CT to be improved, however this effect has not been studied in detail. We scanned phantoms containing either an iodine contrast agent or gold nanoparticles. We used a range of tube voltages and currents. We performed reconstruction with FBP, ITER and a novel, iterative, modal-based reconstruction (IMR) algorithm. We found that noise decreased in an algorithm dependent manner (FBP > ITER > IMR) for every scan and that no differences were observed in attenuation rates of the agents. The contrast to noise ratio (CNR) of iodine was highest at 80 kV, whilst the CNR for gold was highest at 140 kV. The CNR of IMR images was almost tenfold higher than that of FBP images. Similar trends were found in dual energy images formed using these algorithms. In conclusion, IMR-based reconstruction techniques will allow contrast agents to be detected with greater sensitivity, and may allow lower contrast agent doses to be used. PMID:27185492

  20. Long-Lasting Enhancement of Visual Perception with Repetitive Noninvasive Transcranial Direct Current Stimulation

    PubMed Central

    Behrens, Janina R.; Kraft, Antje; Irlbacher, Kerstin; Gerhardt, Holger; Olma, Manuel C.; Brandt, Stephan A.

    2017-01-01

    Understanding processes performed by an intact visual cortex as the basis for developing methods that enhance or restore visual perception is of great interest to both researchers and medical practitioners. Here, we explore whether contrast sensitivity, a main function of the primary visual cortex (V1), can be improved in healthy subjects by repetitive, noninvasive anodal transcranial direct current stimulation (tDCS). Contrast perception was measured via threshold perimetry directly before and after intervention (tDCS or sham stimulation) on each day over 5 consecutive days (24 subjects, double-blind study). tDCS improved contrast sensitivity from the second day onwards, with significant effects lasting 24 h. After the last stimulation on day 5, the anodal group showed a significantly greater improvement in contrast perception than the sham group (23 vs. 5%). We found significant long-term effects in only the central 2–4° of the visual field 4 weeks after the last stimulation. We suspect a combination of two factors contributes to these lasting effects. First, the V1 area that represents the central retina was located closer to the polarization electrode, resulting in higher current density. Second, the central visual field is represented by a larger cortical area relative to the peripheral visual field (cortical magnification). This is the first study showing that tDCS over V1 enhances contrast perception in healthy subjects for several weeks. This study contributes to the investigation of the causal relationship between the external modulation of neuronal membrane potential and behavior (in our case, visual perception). Because the vast majority of human studies only show temporary effects after single tDCS sessions targeting the visual system, our study underpins the potential for lasting effects of repetitive tDCS-induced modulation of neuronal excitability. PMID:28860969

  1. Changes in color vision and contrast sensitivity after descemet membrane endothelial keratoplasty for fuchs endothelial dystrophy.

    PubMed

    Cabrerizo, Javier; Livny, Eitan; Musa, Fayyaz U; Leeuwenburgh, Paulien; van Dijk, Korine; Melles, Gerrit R J

    2014-10-01

    The aim of this study is to evaluate contrast sensitivity, color vision, and subjective patient satisfaction after Descemet membrane endothelial keratoplasty (DMEK) in patients with bilateral Fuchs endothelial dystrophy (FED). From a group of 500 DMEK surgeries performed in our center, patients with a history of bilateral FED and unilateral DMEK were identified. A total of 29 patients were included in the study and divided into 2 groups: phakic (n = 12) and pseudophakic unilateral DMEK (n = 17) and their contralateral, untreated FED-affected eye. In addition, a control group of 10 healthy eyes of 10 patients was included. Pelli-Robson contrast sensitivity and Farnsworth-Munsell 100 hue color vision tests were performed. Subjective optical quality was graded with a questionnaire. Compared with untreated FED-affected eyes, best spectacle-corrected visual acuity was higher after DMEK in phakic and pseudophakic eyes (P = 0.030 and P < 0.001, respectively); a similar result was obtained for contrast sensitivity (P < 0.001 and P < 0.001, respectively). Color vision did not differ between untreated FED-affected and DMEK-operated eyes in the phakic group (P = 0.802) and the pseudophakic group (P = 0.227). Subjective optical quality was better in DMEK-operated eyes than in untreated FED-affected eyes in the phakic group (P < 0.001) and in the pseudophakic group (P < 0.001). In FED, DMEK may not only be effective for obtaining a higher visual acuity but particularly improving the contrast sensitivity may also lead to better subjective optical performance. Although frequently mentioned spontaneously by patients, an objective change in color vision could not be substantiated. Hence, quantifying contrast sensitivity before surgery may aid in the decision for surgery, and in the evaluation of surgical outcome.

  2. Visual function of children with visual and other disabilities in Oman: A case series.

    PubMed

    Gogri, Urmi; Khandekar, Rajiv; Al Harby, Salah

    2016-12-01

    We assessed the visual functioning of the children with special needs in Oman between 2009 and 2012. We present the methods of assessing different visual functions, outcomes, and interventions carried out to improve their functioning. Optometrists assessed visual functions of children of "Day care centres" in Oman. Experts further assessed them and provided low vision care. Ocular movements, refractive corrections, near, distance, contrast color, motion, field of vision, and cognitive visual function test results were noted. Feedback to caregivers was given to improve visual functioning of these children. We grouped 321 participants, (196 [61.1%] boys, age range of 3-18 years) into 61; Down syndrome (DS), 72 with intellectual disabilities (IDs), 67; hearing impaired and 121 with other conditions. Refractive error and lag of accommodation were 26 (42.6%) and 14 (22.6%) among children with DS. Contrast sensitivity was impaired in 8 (12.7%) among hearing impaired children. Defective distant and near vision was in 162 (70%) and 104 (42%) of our cohort. Children with ID were most difficult to assess. Children in a group of other disabilities had a higher proportion of impaired visual functioning. They were given low vision aids (telescopes [22], filters [7], and magnifiers [3]) in large numbers compared to those in other groups. Visual functioning of children with other disabilities show great variation and difficult to group. The care, therefore, should be at individual level. All visual functions cannot be assessed at one time.

  3. Sensitive electrochemical immunoassay for 2,4,6-trinitrotoluene based on functionalized silica nanoparticle labels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Jun; Liu, Guodong; Wu, Hong

    2008-03-03

    We present a poly(guanine)-functionalized silica nanoparticle (NP) label-based electrochemical immunoassay for sensitively detecting 2,4,6-trinitrotoluene (TNT). This immunoassay takes advantage of magnetic bead–based platform for competitive displacement immunoreactions and separation, and use electroactive nanoparticles as labels for signal amplification. For this assay, anti-TNT-coated magnetic beads interacted with TNT analog-conjugated poly(guanine)-silica NPs and formed analog-anti-TNT immunocomplexes on magnetic beads. The immunocomplexes coated magnetic beads were exposed to TNT samples, which resulted in displacing the analog conjugated poly(guanine) silica NPs into solution by TNT. In contrast, there are no guanine residues releasing into the solution in the absence of TNT. The reaction solutionmore » was then separated from the magnetic beads and transferred to the electrode surface for electrochemical measurements of guanine oxidation with Ru(bpy)32+ as mediator. The sensitivity of this TNT assay was greatly enhanced through dual signal amplifications: 1) a large amount of guanine residues on silica nanoparticles is introduced into the test solution by displacement immunoreactions and 2) a Ru(bpy)32+-induced guanine catalytic oxidation further enhances the electrochemical signal. Some experimental parameters for the nanoparticle label-based electrochemical immunoassay were studied and the performance of this assay was evaluated. The method is found to be very sensitive and the detection limit of this assay is ~ 0.1 ng mL-1 TNT. The electrochemical immunoassay based on the poly[guanine]-functionalized silica NP label offers a new approach for sensitive detection of explosives.« less

  4. Sensitive periods for the functional specialization of the neural system for human face processing.

    PubMed

    Röder, Brigitte; Ley, Pia; Shenoy, Bhamy H; Kekunnaya, Ramesh; Bottari, Davide

    2013-10-15

    The aim of the study was to identify possible sensitive phases in the development of the processing system for human faces. We tested the neural processing of faces in 11 humans who had been blind from birth and had undergone cataract surgery between 2 mo and 14 y of age. Pictures of faces and houses, scrambled versions of these pictures, and pictures of butterflies were presented while event-related potentials were recorded. Participants had to respond to the pictures of butterflies (targets) only. All participants, even those who had been blind from birth for several years, were able to categorize the pictures and to detect the targets. In healthy controls and in a group of visually impaired individuals with a history of developmental or incomplete congenital cataracts, the well-known enhancement of the N170 (negative peak around 170 ms) event-related potential to faces emerged, but a face-sensitive response was not observed in humans with a history of congenital dense cataracts. By contrast, this group showed a similar N170 response to all visual stimuli, which was indistinguishable from the N170 response to faces in the controls. The face-sensitive N170 response has been associated with the structural encoding of faces. Therefore, these data provide evidence for the hypothesis that the functional differentiation of category-specific neural representations in humans, presumably involving the elaboration of inhibitory circuits, is dependent on experience and linked to a sensitive period. Such functional specialization of neural systems seems necessary to archive high processing proficiency.

  5. Unilateral Amblyopia Affects Two Eyes: Fellow Eye Deficits in Amblyopia.

    PubMed

    Meier, Kimberly; Giaschi, Deborah

    2017-03-01

    Unilateral amblyopia is a visual disorder that arises after selective disruption of visual input to one eye during critical periods of development. In the clinic, amblyopia is understood as poor visual acuity in an eye that was deprived of pattern vision early in life. By its nature, however, amblyopia has an adverse effect on the development of a binocular visual system and the interactions between signals from two eyes. Visual functions aside from visual acuity are impacted, and many studies have indicated compromised sensitivity in the fellow eye even though it demonstrates normal visual acuity. While these fellow eye deficits have been noted, no overarching theory has been proposed to describe why and under what conditions the fellow eye is impacted by amblyopia. Here, we consider four explanations that may account for decreased fellow eye sensitivity: the fellow eye is adversely impacted by treatment for amblyopia; the maturation of the fellow eye is delayed by amblyopia; fellow eye sensitivity is impacted for visual functions that rely on binocular cortex; and fellow eye deficits reflect an adaptive mechanism that works to equalize the sensitivity of the two eyes. To evaluate these ideas, we describe five visual functions that are commonly reported to be deficient in the amblyopic eye (hyperacuity, contrast sensitivity, spatial integration, global motion, and motion-defined form), and unify the current evidence for fellow eye deficits. Further research targeted at exploring fellow eye deficits in amblyopia will provide us with a broader understanding of normal visual development and how amblyopia impacts the developing visual system.

  6. Differentiating between Alzheimer's Disease and Vascular Cognitive Impairment: Is the "Memory Versus Executive Function" Contrast Still Relevant?

    PubMed

    Andriuta, Daniela; Roussel, Martine; Barbay, Mélanie; Despretz-Wannepain, Sandrine; Godefroy, Olivier

    2018-01-01

    The contrast between memory versus executive function impairments is commonly used to differentiate between neurocognitive disorders (NCDs) due to Alzheimer's disease (AD) and vascular cognitive impairment (VCI). We reconsidered this question because of the current use of AD biomarkers and the recent revision of the criteria for AD, VCI, and dysexecutive syndrome. To establish and compare the neuropsychological profiles in AD (i.e., with positive CSF biomarkers) and in VCI. We included 62 patients with mild or major NCDs due to pure AD (with positive CSF biomarker assays), and 174 patients (from the GRECogVASC cohort) with pure VCI. The neuropsychological profiles were compared after stratification for disease severity (mild or major NCD). We defined a memory-executive function index (the mean z score for the third free recall and the delayed free recall in the Free and Cued Selective Reminding Test minus the mean z score for category fluency and the completion time in the Trail Making Test part B) and determined its diagnostic accuracy. Compared with VCI patients, patients with AD had significantly greater memory impairments (p = 0.001). Executive function was impaired to a similar extent in the two groups (p = 0.11). Behavioral executive disorders were more prominent in the AD group (p = 0.001). Although the two groups differed significant with regard to the memory-executive function index (p < 0.001), the latter's diagnostic accuracy was only moderate (sensitivity: 63%, specificity: 87%). Although the contrast between memory and executive function impairments was supported at the group level it does not reliably discriminate between AD and VCI at the individual level.

  7. Functional dissociation of the left and right fusiform gyrus in self-face recognition.

    PubMed

    Ma, Yina; Han, Shihui

    2012-10-01

    It is well known that the fusiform gyrus is engaged in face perception, such as the processes of face familiarity and identity. However, the functional role of the fusiform gyrus in face processing related to high-level social cognition remains unclear. The current study assessed the functional role of individually defined fusiform face area (FFA) in the processing of self-face physical properties and self-face identity. We used functional magnetic resonance imaging to monitor neural responses to rapidly presented face stimuli drawn from morph continua between self-face (Morph 100%) and a gender-matched friend's face (Morph 0%) in a face recognition task. Contrasting Morph 100% versus Morph 60% that differed in self-face physical properties but were both recognized as the self uncovered neural activity sensitive to self-face physical properties in the left FFA. Contrasting Morphs 50% that were recognized as the self versus a friend on different trials revealed neural modulations associated with self-face identity in the right FFA. Moreover, the right FFA activity correlated with the frequency of recognizing Morphs 50% as the self. Our results provide evidence for functional dissociations of the left and right FFAs in the representations of self-face physical properties and self-face identity. Copyright © 2011 Wiley Periodicals, Inc.

  8. Increasing the availability of l-arginine and nitric oxide increases sensitivity of nitrous oxide (N2O)-insensitive inbred mice to N2O-induced antinociception.

    PubMed

    Chung, Eunhee; Ohgami, Yusuke; Quock, Raymond M

    2016-07-01

    Nitrous oxide (N2O)-induced antinociception in mice is dependent on the neuromodulator nitric oxide (NO). In contrast to C57BL/6J (B6) mice, DBA/2J (D2) mice fail to respond to N2O with a robust antinociceptive response or with an increase in brain nitric oxide synthase (NOS) enzyme activity, suggesting that failure of D2 mice to respond to N2O might result from a deficit of NO function. Therefore, it was of interest to determine whether increasing the availability of NO might increase sensitivity of D2 mice to N2O. Male D2 mice were pretreated with sub-antinociceptive intracerebroventricular doses of the NO donor 3-morpholinosydnoimine or the NO precursor l-arginine then assessed for responsiveness to N2O-induced antinociception using the acetic acid abdominal constriction test. Both pretreatments increased the antinociceptive responsiveness of D2 mice to N2O. These results indicate that the NOS enzyme in D2 mice is functional and that the deficit in NO function that obstructs sensitivity to N2O-induced antinociception may lie in availability or utilization of l-arginine. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Microenvironment-Sensitive Multimodal Contrast Agent for Prostate Cancer Diagnosis

    DTIC Science & Technology

    2015-10-01

    with a biopolymer (i.e. starch ) to improve biocompatibility, and tagged with prostate cancer-targeting ligands. A significant challenge to translation... starch coating of 50 nm and 100 nm SPIONs was crosslinked and coated with amine groups, and then functionalized with NHS-polyethylene glycol (PEG) of...varying molecular weight (i.e., 2k, 5k or 20k Da) as shown in Scheme 1. Scheme 1. Surface modification of starch -coated SPIONs into aminated and

  10. Microenvironment Sensitive Multimodal Contrast Agent for Prostate Cancer Diagnosis

    DTIC Science & Technology

    2016-10-01

    coated with a biopolymer (i.e. starch ) to improve biocompatibility, and tagged with prostate cancer-targeting ligands. A significant challenge to...The starch coating of 50 nm and 100 nm SPIONs was crosslinked and coated with amine groups, and then functionalized with NHS-polyethylene glycol (PEG...of varying molecular weight (i.e., 2k, 5k or 20k Da) as shown in Scheme 1. Scheme 1. Surface modification of starch -coated SPIONs into aminated

  11. T1 weighted brain images at 7 Tesla unbiased for Proton Density, T2* contrast and RF coil receive B1 sensitivity with simultaneous vessel visualization.

    PubMed

    Van de Moortele, Pierre-François; Auerbach, Edwards J; Olman, Cheryl; Yacoub, Essa; Uğurbil, Kâmil; Moeller, Steen

    2009-06-01

    At high magnetic field, MR images exhibit large, undesirable signal intensity variations commonly referred to as "intensity field bias". Such inhomogeneities mostly originate from heterogeneous RF coil B(1) profiles and, with no appropriate correction, are further pronounced when utilizing rooted sum of square reconstruction with receive coil arrays. These artifacts can significantly alter whole brain high resolution T(1)-weighted (T(1)w) images that are extensively utilized for clinical diagnosis, for gray/white matter segmentation as well as for coregistration with functional time series. In T(1) weighted 3D-MPRAGE sequences, it is possible to preserve a bulk amount of T(1) contrast through space by using adiabatic inversion RF pulses that are insensitive to transmit B(1) variations above a minimum threshold. However, large intensity variations persist in the images, which are significantly more difficult to address at very high field where RF coil B(1) profiles become more heterogeneous. Another characteristic of T(1)w MPRAGE sequences is their intrinsic sensitivity to Proton Density and T(2)(*) contrast, which cannot be removed with post-processing algorithms utilized to correct for receive coil sensitivity. In this paper, we demonstrate a simple technique capable of producing normalized, high resolution T(1)w 3D-MPRAGE images that are devoid of receive coil sensitivity, Proton Density and T(2)(*) contrast. These images, which are suitable for routinely obtaining whole brain tissue segmentation at 7 T, provide higher T(1) contrast specificity than standard MPRAGE acquisitions. Our results show that removing the Proton Density component can help in identifying small brain structures and that T(2)(*) induced artifacts can be removed from the images. The resulting unbiased T(1)w images can also be used to generate Maximum Intensity Projection angiograms, without additional data acquisition, that are inherently registered with T(1)w structural images. In addition, we introduce a simple technique to reduce residual signal intensity variations induced by transmit B(1) heterogeneity. Because this approach requires two 3D images, one divided with the other, head motion could create serious problems, especially at high spatial resolution. To alleviate such inter-scan motion problems, we developed a new sequence where the two contrast acquisitions are interleaved within a single scan. This interleaved approach however comes with greater risk of intra-scan motion issues because of a longer single scan time. Users can choose between these two trade offs depending on specific protocols and patient populations. We believe that the simplicity and the robustness of this double contrast based approach to address intensity field bias at high field and improve T(1) contrast specificity, together with the capability of simultaneously obtaining angiography maps, advantageously counter balance the potential drawbacks of the technique, mainly a longer acquisition time and a moderate reduction in signal to noise ratio.

  12. T1 weighted Brain Images at 7 Tesla Unbiased for Proton Density, T2* contrast and RF Coil Receive B1 Sensitivity with Simultaneous Vessel Visualization

    PubMed Central

    Van de Moortele, Pierre-François; Auerbach, Edwards J.; Olman, Cheryl; Yacoub, Essa; Uğurbil, Kâmil; Moeller, Steen

    2009-01-01

    At high magnetic field, MR images exhibit large, undesirable signal intensity variations commonly referred to as “intensity field bias”. Such inhomogeneities mostly originate from heterogeneous RF coil B1 profiles and, with no appropriate correction, are further pronounced when utilizing rooted sum of square reconstruction with receive coil arrays. These artifacts can significantly alter whole brain high resolution T1-weighted (T1w) images that are extensively utilized for clinical diagnosis, for gray/white matter segmentation as well as for coregistration with functional time series. In T1 weighted 3D-MPRAGE sequences, it is possible to preserve a bulk amount of T1 contrast through space by using adiabatic inversion RF pulses that are insensitive to transmit B1 variations above a minimum threshold. However, large intensity variations persist in the images, which are significantly more difficult to address at very high field where RF coil B1 profiles become more heterogeneous. Another characteristic of T1w MPRAGE sequences is their intrinsic sensitivity to Proton Density and T2* contrast, which cannot be removed with post-processing algorithms utilized to correct for receive coil sensitivity. In this paper, we demonstrate a simple technique capable of producing normalized, high resolution T1w 3D-MPRAGE images that are devoid of receive coil sensitivity, Proton Density and T2* contrast. These images, which are suitable for routinely obtaining whole brain tissue segmentation at 7 Tesla, provide higher T1 contrast specificity than standard MPRAGE acquisitions. Our results show that removing the Proton Density component can help identifying small brain structures and that T2* induced artifacts can be removed from the images. The resulting unbiased T1w images can also be used to generate Maximum Intensity Projection angiograms, without additional data acquisition, that are inherently registered with T1w structural images. In addition, we introduce a simple technique to reduce residual signal intensity variations induced by Transmit B1 heterogeneity. Because this approach requires two 3D images, one divided with the other, head motion could create serious problems, especially at high spatial resolution. To alleviate such inter-scan motion problems, we developed a new sequence where the two contrast acquisitions are interleaved within a single scan. This interleaved approach however comes with greater risk of intra-scan motion issues because of a longer single scan time. Users can choose between these two trade offs depending on specific protocols and patient populations. We believe that the simplicity and the robustness of this double contrast based approach to address intensity field bias at high field and improve T1 contrast specificity, together with the capability of simultaneously obtaining angiography maps, advantageously counter balance the potential drawbacks of the technique, mainly a longer acquisition time and a moderate reduction in signal to noise ratio. PMID:19233292

  13. Colour vision in ADHD: part 1--testing the retinal dopaminergic hypothesis.

    PubMed

    Kim, Soyeon; Al-Haj, Mohamed; Chen, Samantha; Fuller, Stuart; Jain, Umesh; Carrasco, Marisa; Tannock, Rosemary

    2014-10-24

    To test the retinal dopaminergic hypothesis, which posits deficient blue color perception in ADHD, resulting from hypofunctioning CNS and retinal dopamine, to which blue cones are exquisitely sensitive. Also, purported sex differences in red color perception were explored. 30 young adults diagnosed with ADHD and 30 healthy young adults, matched on age and gender, performed a psychophysical task to measure blue and red color saturation and contrast discrimination ability. Visual function measures, such as the Visual Activities Questionnaire (VAQ) and Farnsworth-Munsell 100 hue test (FMT), were also administered. Females with ADHD were less accurate in discriminating blue and red color saturation relative to controls but did not differ in contrast sensitivity. Female control participants were better at discriminating red saturation than males, but no sex difference was present within the ADHD group. Poorer discrimination of red as well as blue color saturation in the female ADHD group may be partly attributable to a hypo-dopaminergic state in the retina, given that color perception (blue-yellow and red-green) is based on input from S-cones (short wavelength cone system) early in the visual pathway. The origin of female superiority in red perception may be rooted in sex-specific functional specialization in hunter-gather societies. The absence of this sexual dimorphism for red colour perception in ADHD females warrants further investigation.

  14. Contrast sensitivity function in stereoscopic viewing of Gabor patches on a medical polarized three-dimensional stereoscopic display

    NASA Astrophysics Data System (ADS)

    Rousson, Johanna; Haar, Jérémy; Santal, Sarah; Kumcu, Asli; Platiša, Ljiljana; Piepers, Bastian; Kimpe, Tom; Philips, Wilfried

    2016-03-01

    While three-dimensional (3-D) imaging systems are entering hospitals, no study to date has explored the luminance calibration needs of 3-D stereoscopic diagnostic displays and if they differ from two-dimensional (2-D) displays. Since medical display calibration incorporates the human contrast sensitivity function (CSF), we first assessed the 2-D CSF for benchmarking and then examined the impact of two image parameters on the 3-D stereoscopic CSF: (1) five depth plane (DP) positions (between DP: -171 and DP: 2853 mm), and (2) three 3-D inclinations (0 deg, 45 deg, and 60 deg around the horizontal axis of a DP). Stimuli were stereoscopic images of a vertically oriented 2-D Gabor patch at one of seven frequencies ranging from 0.4 to 10 cycles/deg. CSFs were measured for seven to nine human observers with a staircase procedure. The results indicate that the 2-D CSF model remains valid for a 3-D stereoscopic display regardless of the amount of disparity between the stereo images. We also found that the 3-D CSF at DP≠0 does not differ from the 3-D CSF at DP=0 for DPs and disparities which allow effortless binocular fusion. Therefore, the existing 2-D medical luminance calibration algorithm remains an appropriate tool for calibrating polarized stereoscopic medical displays.

  15. Decreased cortical activation in response to a motion stimulus in anisometropic amblyopic eyes using functional magnetic resonance imaging.

    PubMed

    Bonhomme, Gabrielle R; Liu, Grant T; Miki, Atsushi; Francis, Ellie; Dobre, M-C; Modestino, Edward J; Aleman, David O; Haselgrove, John C

    2006-12-01

    Motion perception abnormalities and extrastriate abnormalities have been suggested in amblyopia. Functional MRI (fMRI) and motion stimuli were used to study whether interocular differences in activation are detectable in motion-sensitive cortical areas in patients with anisometropic amblyopia. We performed fMRI at 1.5 T 4 control subjects (20/20 OU), 1 with monocular suppression (20/25), and 2 with anisometropic amblyopia (20/60, 20/800). Monocular suppression was thought to be form fruste of amblyopia. The experimental stimulus consisted of expanding and contracting concentric rings, whereas the control condition consisted of stationary concentric rings. Activation was determined by contrasting the 2 conditions for each eye. Significant fMRI activation and comparable right and left eye activation was found in V3a and V5 in all control subjects (Average z-values in L vs R contrast 0.42, 0.43) and in the subject with monocular suppression (z = 0.19). The anisometropes exhibited decreased extrastriate activation in their amblyopic eyes compared with the fellow eyes (zs = 2.12, 2.76). Our data suggest motion-sensitive cortical structures may be less active when anisometropic amblyopic eyes are stimulated with moving rings. These results support the hypothesis that extrastriate cortex is affected in anisometropic amblyopia. Although suggestive of a magnocellular defect, the exact mechanism is unclear.

  16. Perceptual color difference metric including a CSF based on the perception threshold

    NASA Astrophysics Data System (ADS)

    Rosselli, Vincent; Larabi, Mohamed-Chaker; Fernandez-Maloigne, Christine

    2008-01-01

    The study of the Human Visual System (HVS) is very interesting to quantify the quality of a picture, to predict which information will be perceived on it, to apply adapted tools ... The Contrast Sensitivity Function (CSF) is one of the major ways to integrate the HVS properties into an imaging system. It characterizes the sensitivity of the visual system to spatial and temporal frequencies and predicts the behavior for the three channels. Common constructions of the CSF have been performed by estimating the detection threshold beyond which it is possible to perceive a stimulus. In this work, we developed a novel approach for spatio-chromatic construction based on matching experiments to estimate the perception threshold. It consists in matching the contrast of a test stimulus with that of a reference one. The obtained results are quite different in comparison with the standard approaches as the chromatic CSFs have band-pass behavior and not low pass. The obtained model has been integrated in a perceptual color difference metric inspired by the s-CIELAB. The metric is then evaluated with both objective and subjective procedures.

  17. Evaluation of the Effects of Conjunctivochalasis Excision on Tear Stability and Contrast Sensitivity

    PubMed Central

    Qiu, Weiqiang; Zhang, Mingzhou; Xu, Ting; Liu, Ziyuan; Lv, Huibin; Wang, Wei; Li, Xuemin

    2016-01-01

    Conjunctivochalasis (CCh) disrupts tear flow and damages tear film stability. This study sought to evaluate the tear stability and contrast sensitivity of patients with CCh on whom CCh excision was performed. The study included 39 eyes from 39 patients; all patients had eyes with grade 2 or 3 CCh, underwent CCh excision, and were evaluated before and three months after the surgery. The evaluated variables included the ocular surface disease index (OSDI), the tear break-up time (TBUT), corneal fluorescein staining, corneal surface irregularity, Schirmer’s I test, the tear meniscus area (TMA), and contrast sensitivity. A follow-up of three months was achieved in 36 eyes for 36 patients. All parameters improved significantly after surgery (p < 0.05), except Schirmer’s I test, thus suggesting that CCh excision is an effective method for reconstructing the lower tear meniscus and improving both tear film stability and corneal surface irregularity. The results further demonstrated a simultaneous increase in contrast sensitivity after surgery. PMID:27892479

  18. Clinical and microperimetric predictors of reading speed in low vision patients: a structural equation modeling approach.

    PubMed

    Giacomelli, Giovanni; Virgili, Gianni; Giansanti, Fabrizio; Sato, Giovanni; Cappello, Ezio; Cruciani, Filippo; Varano, Monica; Menchini, Ugo

    2013-06-27

    To investigate the simultaneous association of several psychophysical measures with reading ability in patients with mild and moderate low vision attending rehabilitation services. Standard measurements of reading ability (Minnesota Reading [MNREAD] charts), visual acuity (Early Treatment of Diabetic Retinopathy Study [ETDRS] charts), contrast sensitivity (Pelli-Robson charts), reading contrast threshold (Reading Explorer [REX] charts), retinal sensitivity, and fixation stability and localization (Micro Perimeter 1 [MP1] fundus perimetry) were obtained in 160 low vision patients with better eye visual acuity ranging from 0.3 to 1.0 logarithm of the minimum angle of resolution and affected by either age-related macular degeneration or diabetic retinopathy. All variables were moderately associated with reading performance measures (MNREAD reading speed and reading acuity and REX reading contrast threshold), as well as among each other. In a structural equation model, REX reading contrast threshold was highly associated with MNREAD reading speed (standardized coefficient, 0.63) and moderately associated with reading acuity (standardized coefficient, -0.30). REX test also mediated the effects of Pelli-Robson contrast sensitivity (standardized coefficient, 0.44), MP1 fixation eccentricity (standardized coefficient, -0.19), and the mean retinal sensitivity (standardized coefficient, 0.23) on reading performance. The MP1 fixation stability was associated with both MNREAD reading acuity (standardized coefficient, -0.24) and MNREAD reading speed (standardized coefficient, 0.23), while ETDRS visual acuity only affected reading acuity (standardized coefficient, 0.44). Fixation instability and contrast sensitivity loss are key factors limiting reading performance of patients with mild or moderate low vision. REX charts directly assess the impact of text contrast on letter recognition and text navigation and may be a useful aid in reading rehabilitation.

  19. Ultrahigh sensitivity endoscopic camera using a new CMOS image sensor: providing with clear images under low illumination in addition to fluorescent images.

    PubMed

    Aoki, Hisae; Yamashita, Hiromasa; Mori, Toshiyuki; Fukuyo, Tsuneo; Chiba, Toshio

    2014-11-01

    We developed a new ultrahigh-sensitive CMOS camera using a specific sensor that has a wide range of spectral sensitivity characteristics. The objective of this study is to present our updated endoscopic technology that has successfully integrated two innovative functions; ultrasensitive imaging as well as advanced fluorescent viewing. Two different experiments were conducted. One was carried out to evaluate the function of the ultrahigh-sensitive camera. The other was to test the availability of the newly developed sensor and its performance as a fluorescence endoscope. In both studies, the distance from the endoscopic tip to the target was varied and those endoscopic images in each setting were taken for further comparison. In the first experiment, the 3-CCD camera failed to display the clear images under low illumination, and the target was hardly seen. In contrast, the CMOS camera was able to display the targets regardless of the camera-target distance under low illumination. Under high illumination, imaging quality given by both cameras was quite alike. In the second experiment as a fluorescence endoscope, the CMOS camera was capable of clearly showing the fluorescent-activated organs. The ultrahigh sensitivity CMOS HD endoscopic camera is expected to provide us with clear images under low illumination in addition to the fluorescent images under high illumination in the field of laparoscopic surgery.

  20. Analysis of Arabidopsis Accessions Hypersensitive to a Loss of Chloroplast Translation1[OPEN

    PubMed Central

    Parker, Nicole; Wang, Yixing; Meinke, David

    2016-01-01

    Natural accessions of Arabidopsis (Arabidopsis thaliana) differ in their ability to tolerate a loss of chloroplast translation. These differences can be attributed in part to variation in a duplicated nuclear gene (ACC2) that targets homomeric acetyl-coenzyme A carboxylase (ACCase) to plastids. This functional redundancy allows limited fatty acid biosynthesis to occur in the absence of heteromeric ACCase, which is encoded in part by the plastid genome. In the presence of functional ACC2, tolerant alleles of several nuclear genes, not yet identified, enhance the growth of seedlings and embryos disrupted in chloroplast translation. ACC2 knockout mutants, by contrast, are hypersensitive. Here we describe an expanded search for hypersensitive accessions of Arabidopsis, evaluate whether all of these accessions are defective in ACC2, and characterize genotype-to-phenotype relationships for homomeric ACCase variants identified among 855 accessions with sequenced genomes. Null alleles with ACC2 nonsense mutations, frameshift mutations, small deletions, genomic rearrangements, and defects in RNA splicing are included among the most sensitive accessions examined. By contrast, most missense mutations affecting highly conserved residues failed to eliminate ACC2 function. Several accessions were identified where sensitivity could not be attributed to a defect in either ACC2 or Tic20-IV, the chloroplast membrane channel required for ACC2 uptake. Overall, these results underscore the central role of ACC2 in mediating Arabidopsis response to a loss of chloroplast translation, highlight future applications of this system to analyzing chloroplast protein import, and provide valuable insights into the mutational landscape of an important metabolic enzyme that is highly conserved throughout eukaryotes. PMID:27707889

  1. The role of the inhibitors of interleukin-6 signal transduction SHP2 and SOCS3 for desensitization of interleukin-6 signalling.

    PubMed Central

    Fischer, Patrick; Lehmann, Ute; Sobota, Radoslaw M; Schmitz, Jochen; Niemand, Claudia; Linnemann, Sonja; Haan, Serge; Behrmann, Iris; Yoshimura, Akihiko; Johnston, James A; Müller-Newen, Gerhard; Heinrich, Peter C; Schaper, Fred

    2004-01-01

    The immediate early response of cells treated with IL-6 (interleukin-6) is the activation of the signal transducer and activator of transcription (STAT)3. The Src homology domain 2 (SH2)-containing protein tyrosine phosphatase SHP2 and the feedback inhibitor SOCS3 (suppressor of cytokine signalling) are potent inhibitors of IL-6 signal transduction. Impaired function of SOCS3 or SHP2 leads to enhanced and prolonged IL-6 signalling. The inhibitory function of both proteins depends on their recruitment to the tyrosine motif 759 within glycoprotein gp130. In contrast to inactivation, desensitization of signal transduction is regarded as impaired responsiveness due to prestimulation. Usually, after activation the sensing receptor becomes inactivated by modifications such as phosphorylation, internalization or degradation. We designed an experimental approach which allows discrimination between desensitization and inactivation of IL-6 signal transduction. We observed that pre-stimulation with IL-6 renders cells less sensitive to further stimulation with IL-6. After several hours, the cells become sensitive again. We show that not only signal transduction through previously activated receptors is affected by desensitization but signalling through receptors which were not targeted by the first stimulation was also attenuated ( trans -desensitization). Interestingly, in contrast to inhibition, desensitization does not depend on the presence of functional SHP2. Furthermore, cells lacking SOCS3 show constitutive STAT3 activation which is not affected by pre-stimulation with IL-6. All these observations suggest that desensitization and inhibition of signalling are mechanistically distinct. PMID:14611646

  2. Vision, visuo-cognition and postural control in Parkinson's disease: An associative pilot study.

    PubMed

    Hill, E; Stuart, S; Lord, S; Del Din, S; Rochester, L

    2016-07-01

    Impaired postural control (PC) is common in patients with Parkinson's disease (PD) and is a major contributor to falls, with significant consequences. Mechanisms underpinning PC are complex and include motor and non-motor features. Research has focused predominantly on motor and sensory inputs. Vision and visuo-cognitive function are also integral to PC but have largely been ignored to date. The aim of this observational cross-sectional pilot study was to explore the relationship of vision and visuo-cognition with PC in PD. Twelve people with PD and ten age-matched healthy controls (HC) underwent detailed assessments for vision, visuo-cognition and postural control. Vision assessments included visual acuity and contrast sensitivity. Visuo-cognition was measured by visuo-perception (object identification), visuo-construction (ability to copy a figure) and visuo-spatial ability (judge distances and location of object within environment). PC was measured by an accelerometer for a range of outcomes during a 2-min static stance. Spearman's correlations identified significant associations. Contrast sensitivity, visuo-spatial ability and postural control (ellipsis) were significantly impaired in PD (p=0.017; p=0.001; and p=0.017, respectively). For PD only, significant correlations were found for higher visuo-spatial function and larger ellipsis (r=0.64; p=0.024) and impaired attention and reduced visuo-spatial function (r=-0.62; p=0.028). Visuo-spatial ability is associated with PC deficit in PD, but in an unexpected direction. This suggests a non-linear pattern of response. Further research is required to examine this novel and important finding. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Functional preservation and variation in the cone opsin genes of nocturnal tarsiers

    PubMed Central

    Ong, Perry S.; Perry, George H.

    2017-01-01

    The short-wavelength sensitive (S-) opsin gene OPN1SW is pseudogenized in some nocturnal primates and retained in others, enabling dichromatic colour vision. Debate on the functional significance of this variation has focused on dark conditions, yet many nocturnal species initiate activity under dim (mesopic) light levels that can support colour vision. Tarsiers are nocturnal, twilight-active primates and exemplary visual predators; they also express different colour vision phenotypes, raising the possibility of discrete adaptations to mesopic conditions. To explore this premise, we conducted a field study in two stages. First, to estimate the level of functional constraint on colour vision, we sequenced OPN1SW in 12 wild-caught Philippine tarsiers (Tarsius syrichta). Second, to explore whether the dichromatic visual systems of Philippine and Bornean (Tarsius bancanus) tarsiers—which express alternate versions of the medium/long-wavelength sensitive (M/L-) opsin gene OPN1MW/OPN1LW—confer differential advantages specific to their respective habitats, we used twilight and moonlight conditions to model the visual contrasts of invertebrate prey. We detected a signature of purifying selection for OPN1SW, indicating that colour vision confers an adaptive advantage to tarsiers. However, this advantage extends to a relatively small proportion of prey–background contrasts, and mostly brown arthropod prey amid leaf litter. We also found that the colour vision of T. bancanus is advantageous for discriminating prey under twilight that is enriched in shorter (bluer) wavelengths, a plausible idiosyncrasy of understorey habitats in Borneo. This article is part of the themed issue ‘Vision in dim light’. PMID:28193820

  4. Retinal specialization through spatially varying cell densities and opsin coexpression in cichlid fish.

    PubMed

    Dalton, Brian E; de Busserolles, Fanny; Marshall, N Justin; Carleton, Karen L

    2017-01-15

    The distinct behaviours of animals and the varied habitats in which animals live place different requirements on their visual systems. A trade-off exists between resolution and sensitivity, with these properties varying across the retina. Spectral sensitivity, which affects both achromatic and chromatic (colour) vision, also varies across the retina, though the function of this inhomogeneity is less clear. We previously demonstrated spatially varying spectral sensitivity of double cones in the cichlid fish Metriaclima zebra owing to coexpression of different opsins. Here, we map the distributions of ganglion cells and cone cells and quantify opsin coexpression in single cones to show these also vary across the retina. We identify an area centralis with peak acuity and infrequent coexpression, which may be suited for tasks such as foraging and detecting male signals. The peripheral retina has reduced ganglion cell densities and increased opsin coexpression. Modeling of cichlid visual tasks indicates that coexpression might hinder colour discrimination of foraging targets and some fish colours. But, coexpression might improve contrast detection of dark objects against bright backgrounds, which might be useful for detecting predators or zooplankton. This suggests a trade-off between acuity and colour discrimination in the central retina versus lower resolution but more sensitive contrast detection in the peripheral retina. Significant variation in the pattern of coexpression among individuals, however, raises interesting questions about the selective forces at work. © 2017. Published by The Company of Biologists Ltd.

  5. Synthesis and characterization of a smart contrast agent sensitive to calcium.

    PubMed

    Dhingra, Kirti; Maier, Martin E; Beyerlein, Michael; Angelovski, Goran; Logothetis, Nikos K

    2008-08-07

    A novel first-generation Ca2+ sensitive contrast agent, Gd-DOPTRA has been synthesized and characterized. The agent shows approximately 100% relaxivity enhancement upon addition of Ca2+. The agent is selective and sensitive to Ca2+ also in the presence of Mg2+ and Zn2+. The relaxivity studies carried out in physiological fluids prove the prospects of the agent for in vivo measurements.

  6. Assessing tumor vascularization as a potential biomarker of imatinib resistance in gastrointestinal stromal tumors by dynamic contrast-enhanced magnetic resonance imaging.

    PubMed

    Consolino, Lorena; Longo, Dario Livio; Sciortino, Marianna; Dastrù, Walter; Cabodi, Sara; Giovenzana, Giovanni Battista; Aime, Silvio

    2017-07-01

    Most metastatic gastrointestinal stromal tumors (GISTs) develop resistance to the first-line imatinib treatment. Recently, increased vessel density and angiogenic markers were reported in GISTs with a poor prognosis, suggesting that angiogenesis is implicated in GIST tumor progression and resistance. The purpose of this study was to investigate the relationship between tumor vasculature and imatinib resistance in different GIST mouse models using a noninvasive magnetic resonance imaging (MRI) functional approach. Immunodeficient mice (n = 8 for each cell line) were grafted with imatinib-sensitive (GIST882 and GIST-T1) and imatinib-resistant (GIST430) human cell lines. Dynamic contrast-enhanced MRI (DCE-MRI) was performed on GIST xenografts to quantify tumor vessel permeability (K trans ) and vascular volume fraction (v p ). Microvessel density (MVD), permeability (mean dextran density, MDD), and angiogenic markers were evaluated by immunofluorescence and western blot assays. Dynamic contrast-enhanced magnetic resonance imaging showed significantly increased vessel density (P < 0.0001) and permeability (P = 0.0002) in imatinib-resistant tumors compared to imatinib-sensitive ones. Strong positive correlations were observed between MRI estimates, K trans and v p , and their related ex vivo values, MVD (r = 0.78 for K trans and r = 0.82 for v p ) and MDD (r = 0.77 for K trans and r = 0.94 for v p ). In addition, higher expression of vascular endothelial growth factor receptors (VEGFR2 and VEFGR3) was seen in GIST430. Dynamic contrast-enhanced magnetic resonance imaging highlighted marked differences in tumor vasculature and microenvironment properties between imatinib-resistant and imatinib-sensitive GISTs, as also confirmed by ex vivo assays. These results provide new insights into the role that DCE-MRI could play in GIST characterization and response to GIST treatment. Validation studies are needed to confirm these findings.

  7. Acute optic neuritis

    PubMed Central

    Galetta, Steven L.; Villoslada, Pablo; Levin, Netta; Shindler, Kenneth; Ishikawa, Hiroshi; Parr, Edward; Cadavid, Diego

    2015-01-01

    Idiopathic demyelinating optic neuritis (ON) most commonly presents as acute unilateral vision loss and eye pain and is frequently associated with multiple sclerosis. Although emphasis is often placed on the good recovery of high-contrast visual acuity, persistent deficits are frequently observed in other aspects of vision, including contrast sensitivity, visual field testing, color vision, motion perception, and vision-related quality of life. Persistent and profound structural and functional changes are often revealed by imaging and electrophysiologic techniques, including optical coherence tomography, visual-evoked potentials, and nonconventional MRI. These abnormalities can impair patients' abilities to perform daily activities (e.g., driving, working) so they have important implications for patients' quality of life. In this article, we review the sequelae from ON, including clinical, structural, and functional changes and their interrelationships. The unmet needs in each of these areas are considered and the progress made toward meeting those needs is examined. Finally, we provide an overview of past and present investigational approaches for disease modification in ON. PMID:26236761

  8. The role of punishment and reward sensitivity in the emotional labor process: a within-person perspective.

    PubMed

    Schreurs, Bert; Guenter, Hannes; Hülsheger, Ute; van Emmerik, Hetty

    2014-01-01

    In this diary study, we tested the possibility that dispositional reward and punishment sensitivity, two central constructs of reinforcement sensitivity theory, would modify the relationship between emotional labor and job-related well-being (i.e., work engagement, emotional exhaustion, depersonalization). Specifically, based on a social functional account of emotion, we hypothesized that surface acting entails the risk of social disapproval and therefore may be more detrimental for high than for low punishment-sensitive individuals. In contrast, deep acting is hypothesized to hold the promise of social approval and therefore may be more beneficial for high than for low reward-sensitive individuals. Hypotheses were tested in a sample of 237 service workers (N = 1,584 daily reports) who completed a general survey and daily surveys over the course of 10 working days. Multilevel analyses showed that surface acting was detrimental to well-being, and more strongly so for high than for low punishment-sensitive individuals. The results are consistent with the idea that heightened sensitivity to social disapproval aggravates the negative effects of surface acting. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  9. Reducing Spatial Uncertainty Through Attentional Cueing Improves Contrast Sensitivity in Regions of the Visual Field With Glaucomatous Defects

    PubMed Central

    Phu, Jack; Kalloniatis, Michael; Khuu, Sieu K.

    2018-01-01

    Purpose Current clinical perimetric test paradigms present stimuli randomly to various locations across the visual field (VF), inherently introducing spatial uncertainty, which reduces contrast sensitivity. In the present study, we determined the extent to which spatial uncertainty affects contrast sensitivity in glaucoma patients by minimizing spatial uncertainty through attentional cueing. Methods Six patients with open-angle glaucoma and six healthy subjects underwent laboratory-based psychophysical testing to measure contrast sensitivity at preselected locations at two eccentricities (9.5° and 17.5°) with two stimulus sizes (Goldmann sizes III and V) under different cueing conditions: 1, 2, 4, or 8 points verbally cued. Method of Constant Stimuli and a single-interval forced-choice procedure were used to generate frequency of seeing (FOS) curves at locations with and without VF defects. Results At locations with VF defects, cueing minimizes spatial uncertainty and improves sensitivity under all conditions. The effect of cueing was maximal when one point was cued, and rapidly diminished when more points were cued (no change to baseline with 8 points cued). The slope of the FOS curve steepened with reduced spatial uncertainty. Locations with normal sensitivity in glaucomatous eyes had similar performance to that of healthy subjects. There was a systematic increase in uncertainty with the depth of VF loss. Conclusions Sensitivity measurements across the VF are negatively affected by spatial uncertainty, which increases with greater VF loss. Minimizing uncertainty can improve sensitivity at locations of deficit. Translational Relevance Current perimetric techniques introduce spatial uncertainty and may therefore underestimate sensitivity in regions of VF loss. PMID:29600116

  10. Quantitation of MRI sensitivity to quasi-monodisperse microbubble contrast agents for spatially resolved manometry.

    PubMed

    Bencsik, Martin; Al-Rwaili, Amgad; Morris, Robert; Fairhurst, David J; Mundell, Victoria; Cave, Gareth; McKendry, Jonathan; Evans, Stephen

    2013-11-01

    The direct in-vivo measurement of fluid pressure cannot be achieved with MRI unless it is done with the contribution of a contrast agent. No such contrast agents are currently available commercially, whilst those demonstrated previously only produced qualitative results due to their broad size distribution. Our aim is to quantitate then model the MR sensitivity to the presence of quasi-monodisperse microbubble populations. Lipid stabilised microbubble populations with mean radius 1.2 ± 0.8 μm have been produced by mechanical agitation. Contrast agents with increasing volume fraction of bubbles up to 4% were formed and the contribution the bubbles bring to the relaxation rate was quantitated. A periodic pressure change was also continuously applied to the same contrast agent, until MR signal changes were only due to bubble radius change and not due to a change in bubble density. The MR data compared favourably with the prediction of an improved numerical simulation. An excellent MR sensitivity of 23 % bar(-1) has been demonstrated. This work opens up the possibility of generating microbubble preparations tailored to specific applications with optimised MR sensitivity, in particular MRI based in-vivo manometry. Copyright © 2012 Wiley Periodicals, Inc.

  11. Imaging of dental material by polarization-sensitive optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Dichtl, Sabine; Baumgartner, Angela; Hitzenberger, Christoph K.; Moritz, Andreas; Wernisch, Johann; Robl, Barbara; Sattmann, Harald; Leitgeb, Rainer; Sperr, Wolfgang; Fercher, Adolf F.

    1999-05-01

    Partial coherence interferometry (PCI) and optical coherence tomography (OCT) are noninvasive and noncontact techniques for high precision biometry and for obtaining cross- sectional images of biologic structures. OCT was initially introduced to depict the transparent tissue of the eye. It is based on interferometry employing the partial coherence properties of a light source with high spatial coherence ut short coherence length to image structures with a resolution of the order of a few microns. Recently this technique has been modified for cross section al imaging of dental and periodontal tissues. In vitro and in vivo OCT images have been recorded, which distinguish enamel, cemento and dentin structures and provide detailed structural information on clinical abnormalities. In contrast to convention OCT, where the magnitude of backscattered light as a function of depth is imaged, polarization sensitive OCT uses backscattered light to image the magnitude of the birefringence in the sample as a function of depth. First polarization sensitive OCT recordings show, that changes in the mineralization status of enamel or dentin caused by caries or non-caries lesions can result in changes of the polarization state of the light backscattered by dental material. Therefore polarization sensitive OCT might provide a new diagnostic imaging modality in clinical and research dentistry.

  12. Viewing Olfactory Affective Responses Through the Sniff Prism: Effect of Perceptual Dimensions and Age on Olfactomotor Responses to Odors

    PubMed Central

    Ferdenzi, Camille; Fournel, Arnaud; Thévenet, Marc; Coppin, Géraldine; Bensafi, Moustafa

    2015-01-01

    Sniffing, which is the active sampling of olfactory information through the nasal cavity, is part of the olfactory percept. It is influenced by stimulus properties, affects how an odor is perceived, and is sufficient (without an odor being present) to activate the olfactory cortex. However, many aspects of the affective correlates of sniffing behavior remain unclear, in particular the modulation of volume and duration as a function of odor hedonics. The present study used a wide range of odorants with contrasted hedonic valence to test: (1) which psychophysical function best describes the relationship between sniffing characteristics and odor hedonics (e.g., linear, or polynomial); (2) whether sniffing characteristics are sensitive to more subtle variations in pleasantness than simple pleasant-unpleasant contrast; (3) how sensitive sniffing is to other perceptual dimensions of odors such as odor familiarity or edibility; and (4) whether the sniffing/hedonic valence relationship is valid in other populations than young adults, such as the elderly. Four experiments were conducted, using 16–48 odorants each, and recruiting a total of 102 participants, including a group of elderly people. Results of the four experiments were very consistent in showing that sniffing was sensitive to subtle variations in unpleasantness but not to subtle variations in pleasantness, and that, the more unpleasant the odor, the more limited the spontaneous sampling of olfactory information through the nasal cavity (smaller volume, shorter duration). This also applied, although to a lesser extent, to elderly participants. Relationships between sniffing and other perceptual dimensions (familiarity, edibility) were less clear. It was concluded that sniffing behavior might be involved in adaptive responses protecting the subject from possibly harmful substances. PMID:26635683

  13. Four theorems on the psychometric function.

    PubMed

    May, Keith A; Solomon, Joshua A

    2013-01-01

    In a 2-alternative forced-choice (2AFC) discrimination task, observers choose which of two stimuli has the higher value. The psychometric function for this task gives the probability of a correct response for a given stimulus difference, Δx. This paper proves four theorems about the psychometric function. Assuming the observer applies a transducer and adds noise, Theorem 1 derives a convenient general expression for the psychometric function. Discrimination data are often fitted with a Weibull function. Theorem 2 proves that the Weibull "slope" parameter, β, can be approximated by β(Noise) x β(Transducer), where β(Noise) is the β of the Weibull function that fits best to the cumulative noise distribution, and β(Transducer) depends on the transducer. We derive general expressions for β(Noise) and β(Transducer), from which we derive expressions for specific cases. One case that follows naturally from our general analysis is Pelli's finding that, when d' ∝ (Δx)(b), β ≈ β(Noise) x b. We also consider two limiting cases. Theorem 3 proves that, as sensitivity improves, 2AFC performance will usually approach that for a linear transducer, whatever the actual transducer; we show that this does not apply at signal levels where the transducer gradient is zero, which explains why it does not apply to contrast detection. Theorem 4 proves that, when the exponent of a power-function transducer approaches zero, 2AFC performance approaches that of a logarithmic transducer. We show that the power-function exponents of 0.4-0.5 fitted to suprathreshold contrast discrimination data are close enough to zero for the fitted psychometric function to be practically indistinguishable from that of a log transducer. Finally, Weibull β reflects the shape of the noise distribution, and we used our results to assess the recent claim that internal noise has higher kurtosis than a Gaussian. Our analysis of β for contrast discrimination suggests that, if internal noise is stimulus-independent, it has lower kurtosis than a Gaussian.

  14. Modification of YAPE keypoint detection algorithm for wide local contrast range images

    NASA Astrophysics Data System (ADS)

    Lukoyanov, A.; Nikolaev, D.; Konovalenko, I.

    2018-04-01

    Keypoint detection is an important tool of image analysis, and among many contemporary keypoint detection algorithms YAPE is known for its computational performance, allowing its use in mobile and embedded systems. One of its shortcomings is high sensitivity to local contrast which leads to high detection density in high-contrast areas while missing detections in low-contrast ones. In this work we study the contrast sensitivity of YAPE and propose a modification which compensates for this property on images with wide local contrast range (Yet Another Contrast-Invariant Point Extractor, YACIPE). As a model example, we considered the traffic sign recognition problem, where some signs are well-lighted, whereas others are in shadows and thus have low contrast. We show that the number of traffic signs on the image of which has not been detected any keypoints is 40% less for the proposed modification compared to the original algorithm.

  15. Contrast summation across eyes and space is revealed along the entire dipper function by a "Swiss cheese" stimulus.

    PubMed

    Meese, Tim S; Baker, Daniel H

    2011-01-27

    Previous contrast discrimination experiments have shown that luminance contrast is summed across ocular (T. S. Meese, M. A. Georgeson, & D. H. Baker, 2006) and spatial (T. S. Meese & R. J. Summers, 2007) dimensions at threshold and above. However, is this process sufficiently general to operate across the conjunction of eyes and space? Here we used a "Swiss cheese" stimulus where the blurred "holes" in sine-wave carriers were of equal area to the blurred target ("cheese") regions. The locations of the target regions in the monocular image pairs were interdigitated across eyes such that their binocular sum was a uniform grating. When pedestal contrasts were above threshold, the monocular neural images contained strong evidence that the high-contrast regions in the two eyes did not overlap. Nevertheless, sensitivity to dual contrast increments (i.e., to contrast increments in different locations in the two eyes) was a factor of ∼1.7 greater than to single increments (i.e., increments in a single eye), comparable with conventional binocular summation. This provides evidence for a contiguous area summation process that operates at all contrasts and is influenced little, if at all, by eye of origin. A three-stage model of contrast gain control fitted the results and possessed the properties of ocularity invariance and area invariance owing to its cascade of normalization stages. The implications for a population code for pattern size are discussed.

  16. Association between visual impairment and patient-reported visual disability at different stages of cataract surgery.

    PubMed

    Acosta-Rojas, E Ruthy; Comas, Mercè; Sala, Maria; Castells, Xavier

    2006-10-01

    To evaluate the association between visual impairment (visual acuity, contrast sensitivity, stereopsis) and patient-reported visual disability at different stages of cataract surgery. A cohort of 104 patients aged 60 years and over with bilateral cataract was assessed preoperatively, after first-eye surgery (monocular pseudophakia) and after second-eye surgery (binocular pseudophakia). Partial correlation coefficients (PCC) and linear regression models were calculated. In patients with bilateral cataracts, visual disability was associated with visual acuity (PCC = -0.30) and, to a lesser extent, with contrast sensitivity (PCC = 0.16) and stereopsis (PCC = -0.09). In monocular and binocular pseudophakia, visual disability was more strongly associated with stereopsis (PCC = -0.26 monocular and -0.51 binocular) and contrast sensitivity (PCC = 0.18 monocular and 0.34 binocular) than with visual acuity (PCC = -0.18 monocular and -0.18 binocular). Visual acuity, contrast sensitivity and stereopsis accounted for between 17% and 42% of variance in visual disability. The association of visual impairment with patient-reported visual disability differed at each stage of cataract surgery. Measuring other forms of visual impairment independently from visual acuity, such as contrast sensitivity or stereopsis, could be important in evaluating both needs and outcomes in cataract surgery. More comprehensive assessment of the impact of cataract on patients should include measurement of both visual impairment and visual disability.

  17. Interactions between chromatic- and luminance-contrast-sensitive stereopsis mechanisms.

    PubMed

    Simmons, David R; Kingdom, Frederick A A

    2002-06-01

    It is well known that chromatic information can assist in solving the stereo correspondence problem. It has also been suggested that there are two independent first-order stereopsis mechanisms, one sensitive to chromatic contrast and the other sensitive to luminance contrast (Vision Research 37 (1997) 1271). Could the effect of chromatic information on stereo correspondence be subserved by interactions between these mechanisms? To address this question, disparity thresholds (1/stereoacuity) were measured using 0.5 cpd Gabor patches. The stimuli possessed different relative amounts of chromatic and luminance contrast which could be correlated or anti-correlated between the eyes. Stereoscopic performance with these compound stimuli was compared to that with purely isoluminant and isochromatic stimuli at different contrasts. It was found that anti-correlated chromatic contrast severely disrupted stereopsis with achromatic stimuli and that anti-correlated luminance contrast severely disrupted stereopsis with chromatic stimuli. Less dramatic, but still significant, was the improvement in stereoacuity obtained using correlated colour and luminance contrast. These data are consistent with there being positive and negative interactions between chromatic and achromatic stereopsis mechanisms that take place after the initial encoding of disparity information, but before the extraction of stereoscopic depth. These interactions can be modelled satisfactorily assuming probability summation of depth sign information between independent mechanisms.

  18. Elemental Identification by Combining Atomic Force Microscopy and Kelvin Probe Force Microscopy.

    PubMed

    Schulz, Fabian; Ritala, Juha; Krejčí, Ondrej; Seitsonen, Ari Paavo; Foster, Adam S; Liljeroth, Peter

    2018-06-01

    There are currently no experimental techniques that combine atomic-resolution imaging with elemental sensitivity and chemical fingerprinting on single molecules. The advent of using molecular-modified tips in noncontact atomic force microscopy (nc-AFM) has made it possible to image (planar) molecules with atomic resolution. However, the mechanisms responsible for elemental contrast with passivated tips are not fully understood. Here, we investigate elemental contrast by carrying out both nc-AFM and Kelvin probe force microscopy (KPFM) experiments on epitaxial monolayer hexagonal boron nitride (hBN) on Ir(111). The hBN overlayer is inert, and the in-plane bonds connecting nearest-neighbor boron and nitrogen atoms possess strong covalent character and a bond length of only ∼1.45 Å. Nevertheless, constant-height maps of both the frequency shift Δ f and the local contact potential difference exhibit striking sublattice asymmetry. We match the different atomic sites with the observed contrast by comparison with nc-AFM image simulations based on the density functional theory optimized hBN/Ir(111) geometry, which yields detailed information on the origin of the atomic-scale contrast.

  19. Spatial frequency dependence of target signature for infrared performance modeling

    NASA Astrophysics Data System (ADS)

    Du Bosq, Todd; Olson, Jeffrey

    2011-05-01

    The standard model used to describe the performance of infrared imagers is the U.S. Army imaging system target acquisition model, based on the targeting task performance metric. The model is characterized by the resolution and sensitivity of the sensor as well as the contrast and task difficulty of the target set. The contrast of the target is defined as a spatial average contrast. The model treats the contrast of the target set as spatially white, or constant, over the bandlimit of the sensor. Previous experiments have shown that this assumption is valid under normal conditions and typical target sets. However, outside of these conditions, the treatment of target signature can become the limiting factor affecting model performance accuracy. This paper examines target signature more carefully. The spatial frequency dependence of the standard U.S. Army RDECOM CERDEC Night Vision 12 and 8 tracked vehicle target sets is described. The results of human perception experiments are modeled and evaluated using both frequency dependent and independent target signature definitions. Finally the function of task difficulty and its relationship to a target set is discussed.

  20. A novel theory of experiential avoidance in generalized anxiety disorder: A review and synthesis of research supporting a contrast avoidance model of worry☆,☆☆

    PubMed Central

    Newman, Michelle G.; Llera, Sandra J.

    2011-01-01

    An important emphasis of the literature on generalized anxiety disorder (GAD) has been to achieve a greater understanding of the function of emotion (e.g., avoidance, dysregulation) in the etiology and maintenance of this disorder. The purpose of the following paper is to propose a new way of conceptualizing emotional sequelae in GAD by detailing the Contrast Avoidance Model of Worry. In presenting this model, we review theory and data that led to our current position, which is that individuals with GAD are more sensitive to feeling emotionally vulnerable to unexpected negative events, and that worry (the key pathological feature of GAD) is employed to prolong and maintain a negative emotional state thereby avoiding an unexpected negative emotional shift, or contrast experience. We also discuss implications for treatment given the presence of a new target for emotional exposure techniques. Finally, we establish the Contrast Avoidance Model within the framework of extant theories and models of pathogenic processes of GAD. PMID:21334285

  1. Adaptive Colour Contrast Coding in the Salamander Retina Efficiently Matches Natural Scene Statistics

    PubMed Central

    Vasserman, Genadiy; Schneidman, Elad; Segev, Ronen

    2013-01-01

    The visual system continually adjusts its sensitivity to the statistical properties of the environment through an adaptation process that starts in the retina. Colour perception and processing is commonly thought to occur mainly in high visual areas, and indeed most evidence for chromatic colour contrast adaptation comes from cortical studies. We show that colour contrast adaptation starts in the retina where ganglion cells adjust their responses to the spectral properties of the environment. We demonstrate that the ganglion cells match their responses to red-blue stimulus combinations according to the relative contrast of each of the input channels by rotating their functional response properties in colour space. Using measurements of the chromatic statistics of natural environments, we show that the retina balances inputs from the two (red and blue) stimulated colour channels, as would be expected from theoretical optimal behaviour. Our results suggest that colour is encoded in the retina based on the efficient processing of spectral information that matches spectral combinations in natural scenes on the colour processing level. PMID:24205373

  2. German and Korean mothers' sensitivity and related parenting beliefs

    PubMed Central

    Ziehm, Jeanette; Trommsdorff, Gisela; Heikamp, Tobias; Park, Seong-Yeon

    2013-01-01

    This study contributes to a differentiated understanding of maternal sensitivity in cultural and situational context. We investigated differences and similarities in German and Korean mothers' maternal sensitivity. We interviewed 92 German and 100 Korean mothers of first graders about their preference for proactive (anticipating children's needs) or reactive sensitivity (responding to children's direct cues) in different scenarios. Related parenting beliefs were assessed by asking the mothers to explain the reasons why they would prefer specific parenting behaviors. Results revealed significant cultural differences in reactive vs. proactive sensitivity preferences. Overall, German mothers were more likely to indicate that a mother should respond reactively and less likely to report that a mother should act proactively than were Korean mothers. Korean mothers gave preference to both reactive and proactive sensitivity depending on the scenario. With regard to parenting beliefs, analyses revealed that German and Korean mothers who preferred reactive sensitivity mainly explained their choices as attempts to encourage children's development of independence. In contrast, Korean and German mothers with a preference for proactive sensitivity were more likely to report that mothers would assist their children due to their immaturity in dealing with emotional distress. Results are discussed in the framework of the different meanings and functions of maternal sensitivity for socialization in different cultural contexts. PMID:23986740

  3. Strain difference in amiloride-sensitivity of salt-induced responses in mouse non-dissociated taste cells.

    PubMed

    Miyamoto, T; Fujiyama, R; Okada, Y; Sato, T

    1999-12-17

    The chorda tympani nerve responses to NaCl in a mouse strain, C57BL/6 are known to be much more sensitive than those in BALB/c. We compared the NaCl-induced responses obtained from taste cells of the fungiform papillae in these two strains of mice. Amiloride inhibited, in the same degree, the responses induced by a bath-application of normal extracellular solution (NES) containing 140 mM NaCl in either taste cells of C57BL/6 and BALB/c mice. In contrast, amiloride inhibited 62% of responses induced by an apically applied 0.5 M NaCl in the C57BL/6 strain, but only 33% of responses in the BALB/c strain. These results suggest that the difference in amiloride-sensitivity between taste cells in both strains mainly derives from the difference in density of functional amiloride sensitive Na+ channels at the apical receptive membrane but not at the basolateral membrane.

  4. DriveSafe and DriveAware Assessment Tools Are a Measure of Driving-Related Function and Predicts Self-Reported Restriction for Older Drivers.

    PubMed

    Allan, Claire; Coxon, Kristy; Bundy, Anita; Peattie, Laura; Keay, Lisa

    2016-06-01

    Safety concerns together with aging of the driving population has prompted research into clinic-based driving assessments. This study investigates the relationship between the DriveSafe and DriveAware assessments and restriction of driving. Community-dwelling adults aged more than 75 (n = 380) were recruited in New South Wales, Australia. Questionnaires were administered to assess driving habits and functional assessments to assess driving-related function. Self-reported restriction was prevalent in this cross-sectional sample (62%) and was related to DriveSafe scores and personal circumstances but not DriveAware scores. DriveSafe scores were correlated with better performance on the Trail-Making Test (TMT; β = -2.94, p < .0001) and better contrast sensitivity (β = 48.70, p < .0001). Awareness was associated with better performance on the TMT (β = 0.08, p < .0001). Our data suggest that DriveSafe and DriveAware are sensitive to deficits in vision and cognition, and drivers with worse DriveSafe scores self-report restricting their driving. © The Author(s) 2015.

  5. 3D non-contrast-enhanced ECG-gated MR angiography of the lower extremities with dual-source radiofrequency transmission at 3.0 T: Intraindividual comparison with contrast-enhanced MR angiography in PAOD patients.

    PubMed

    Rasper, Michael; Wildgruber, Moritz; Settles, Marcus; Eckstein, Hans-Henning; Zimmermann, Alexander; Reeps, Christian; Rummeny, Ernst J; Huber, Armin M

    2016-09-01

    To compare prospectively image quality and diagnostic confidence of flow-sensitive 3D turbo spin echo (TSE)-based non-contrast-enhanced MR angiography (NE-MRA) at 3.0 T using dual-source radiofrequency (RF) transmission with contrast-enhanced MRA (CE-MRA) in patients with peripheral arterial occlusive disease (PAOD). After consent was obtained, 35 patients (mean age 69.1 ± 10.6 years) with PAOD stage II-IV underwent NE-MRA followed by CE-MRA. Signal-to-noise ratio and contrast-to-noise ratio were calculated. Subjective image quality was independently assessed by two radiologists and stenosis scoring was performed in 875 arterial segments. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for stenosis classification were calculated using CE-MRA as a reference method. Diagnostic agreement with CE-MRA was evaluated with Cohen's kappa statistics. NE-MRA provided high objective and subjective image quality at all levels of the arterial tree. Sensitivity and specificity for the detection of relevant stenosis was 91 % and 89 %, respectively; the NPV was 96 % and the PPV 78 %. There was good concordance between CE-MRA and NE-MRA in stenosis scoring. 3D electrocardiography (ECG)-gated TSE NE-MRA with patient-adaptive dual-source RF transmission at 3.0 T is a promising alternative for PAOD patients with contraindications for gadolinium-based contrast agents. It offers high sensitivity and NPV values in the detection of clinically relevant arterial stenosis. • Flow-sensitive TSE NE-MRA is a promising technique for PAOD evaluation. • Diagnostic accuracy is comparable to contrast-enhanced MRA. • NE-MRA eliminates the risk of NSF in patients with renal insufficiency. • Costs arising from the use of contrast agents can be avoided.

  6. Brightness discrimination and contrast sensitivity in chronic glaucoma--a clinical study.

    PubMed Central

    Teoh, S L; Allan, D; Dutton, G N; Foulds, W S

    1990-01-01

    The visual acuity, the difference in sensitivity of the two eyes to light (brightness ratio), and contrast sensitivity were assessed in 28 patients with chronic open angle glaucoma and compared with those of 41 normal controls of similar ages and visual acuity. The results obtained were related to the results of Tübingen visual field analysis in patients with glaucoma. Twenty-four of the 28 glaucoma patients (86%) had a significant disparity in brightness ratio between the two eyes. This was found to match the frequency of visual field loss. Moreover, there was a significant relationship between the interocular differences in brightness sense and the difference in the degree of visual field loss between the two eyes. Of the glaucoma patients 39% had sum contrast sensitivities outside the normal range for age-matched normal controls. No significant correlation was found between the interocular difference in brightness sense and the visual acuity or the interocular difference in sum contrast sensitivity. It is concluded that, in the presence of a normal visual acuity, the brightness ratio test warrants evaluation as a potential screening test for chronic open angle glaucoma. PMID:2186795

  7. Effect of text type on near work-induced contrast adaptation in myopic and emmetropic young adults.

    PubMed

    Yeo, Anna C H; Atchison, David A; Schmid, Katrina L

    2013-02-27

    Contrast adaptation has been speculated to be an error signal for emmetropization. Myopic children exhibit higher contrast adaptation than emmetropic children. This study aimed to determine whether contrast adaptation varies with the type of text viewed by emmetropic and myopic young adults. Baseline contrast sensitivity was determined in 25 emmetropic and 25 spectacle-corrected myopic young adults for 0.5, 1.2, 2.7, 4.4, and 6.2 cycles per degree (cpd) horizontal sine wave gratings. The adults spent periods looking at a 6.2 cpd high-contrast horizontal grating and reading lines of English and Chinese text (these texts comprised 1.2 cpd row and 6 cpd stroke frequencies). The effects of these near tasks on contrast sensitivity were determined, with decreases in sensitivity indicating contrast adaptation. Contrast adaptation was affected by the near task (F2,672 = 43.0; P < 0.001). Adaptation was greater for the grating task (0.13 ± 0.17 log unit, averaged across all frequencies) than reading tasks, but there was no significant difference between the two reading tasks (English 0.05 ± 0.13 log unit versus Chinese 0.04 ± 0.13 log unit). The myopic group showed significantly greater adaptation (by 0.04, 0.04, and 0.05 log units for English, Chinese, and grating tasks, respectively) than the emmetropic group (F1,48 = 5.0; P = 0.03). In young adults, reading Chinese text induced similar contrast adaptation as reading English text. Myopes exhibited greater contrast adaptation than emmetropes. Contrast adaptation, independent of text type, might be associated with myopia development.

  8. Interaction of aberrations, diffraction, and quantal fluctuations determine the impact of pupil size on visual quality.

    PubMed

    Xu, Renfeng; Wang, Huachun; Thibos, Larry N; Bradley, Arthur

    2017-04-01

    Our purpose is to develop a computational approach that jointly assesses the impact of stimulus luminance and pupil size on visual quality. We compared traditional optical measures of image quality and those that incorporate the impact of retinal illuminance dependent neural contrast sensitivity. Visually weighted image quality was calculated for a presbyopic model eye with representative levels of chromatic and monochromatic aberrations as pupil diameter was varied from 7 to 1 mm, stimulus luminance varied from 2000 to 0.1  cd/m2, and defocus varied from 0 to -2 diopters. The model included the effects of quantal fluctuations on neural contrast sensitivity. We tested the model's predictions for five cycles per degree gratings by measuring contrast sensitivity at 5  cyc/deg. Unlike the traditional Strehl ratio and the visually weighted area under the modulation transfer function, the visual Strehl ratio derived from the optical transfer function was able to capture the combined impact of optics and quantal noise on visual quality. In a well-focused eye, provided retinal illuminance is held constant as pupil size varies, visual image quality scales approximately as the square root of illuminance because of quantum fluctuations, but optimum pupil size is essentially independent of retinal illuminance and quantum fluctuations. Conversely, when stimulus luminance is held constant (and therefore illuminance varies with pupil size), optimum pupil size increases as luminance decreases, thereby compensating partially for increased quantum fluctuations. However, in the presence of -1 and -2 diopters of defocus and at high photopic levels where Weber's law operates, optical aberrations and diffraction dominate image quality and pupil optimization. Similar behavior was observed in human observers viewing sinusoidal gratings. Optimum pupil size increases as stimulus luminance drops for the well-focused eye, and the benefits of small pupils for improving defocused image quality remain throughout the photopic and mesopic ranges. However, restricting pupils to <2  mm will cause significant reductions in the best focus vision at low photopic and mesopic luminances.

  9. High resolution laboratory grating-based x-ray phase-contrast CT

    NASA Astrophysics Data System (ADS)

    Viermetz, Manuel P.; Birnbacher, Lorenz J. B.; Fehringer, Andreas; Willner, Marian; Noel, Peter B.; Pfeiffer, Franz; Herzen, Julia

    2017-03-01

    Grating-based phase-contrast computed tomography (gbPC-CT) is a promising imaging method for imaging of soft tissue contrast without the need of any contrast agent. The focus of this study is the increase in spatial resolution without loss in sensitivity to allow visualization of pathologies comparable to the convincing results obtained at the synchrotron. To improve the effective pixel size a super-resolution reconstruction based on subpixel shifts involving a deconvolution of the image is applied on differential phase-contrast data. In our study we could achieve an effective pixel sizes of 28mm without any drawback in terms of sensitivity or the ability to measure quantitative data.

  10. The functional organization of the left STS: a large scale meta-analysis of PET and fMRI studies of healthy adults

    PubMed Central

    Liebenthal, Einat; Desai, Rutvik H.; Humphries, Colin; Sabri, Merav; Desai, Anjali

    2014-01-01

    The superior temporal sulcus (STS) in the left hemisphere is functionally diverse, with sub-areas implicated in both linguistic and non-linguistic functions. However, the number and boundaries of distinct functional regions remain to be determined. Here, we present new evidence, from meta-analysis of a large number of positron emission tomography (PET) and functional magnetic resonance imaging (fMRI) studies, of different functional specificity in the left STS supporting a division of its middle to terminal extent into at least three functional areas. The middle portion of the left STS stem (fmSTS) is highly specialized for speech perception and the processing of language material. The posterior portion of the left STS stem (fpSTS) is highly versatile and involved in multiple functions supporting semantic memory and associative thinking. The fpSTS responds to both language and non-language stimuli but the sensitivity to non-language material is greater. The horizontal portion of the left STS stem and terminal ascending branches (ftSTS) display intermediate functional specificity, with the anterior-dorsal ascending branch (fatSTS) supporting executive functions and motor planning and showing greater sensitivity to language material, and the horizontal stem and posterior-ventral ascending branch (fptSTS) supporting primarily semantic processing and displaying greater sensitivity to non-language material. We suggest that the high functional specificity of the left fmSTS for speech is an important means by which the human brain achieves exquisite affinity and efficiency for native speech perception. In contrast, the extreme multi-functionality of the left fpSTS reflects the role of this area as a cortical hub for semantic processing and the extraction of meaning from multiple sources of information. Finally, in the left ftSTS, further functional differentiation between the dorsal and ventral aspect is warranted. PMID:25309312

  11. A System for Controlled Presentation of the Arden Contrast Sensitivity Test.

    DTIC Science & Technology

    1985-12-01

    and Woo,1978); I.?glaucoma (Atkin, et al,1979); amblyopia (Hess,1979); retinal degeneration (Woo and Long,1979); multiple sclerosis (Regan, et al...decrease, contrast sensitivity diminishes, and imaging L shifts to an area covering 12 -15 of the peripheral macula . The theoretical threshold grid

  12. Geometrically confined ultrasmall gadolinium oxide nanoparticles boost the T1 contrast ability

    NASA Astrophysics Data System (ADS)

    Ni, Kaiyuan; Zhao, Zhenghuan; Zhang, Zongjun; Zhou, Zijian; Yang, Li; Wang, Lirong; Ai, Hua; Gao, Jinhao

    2016-02-01

    High-performance magnetic resonance imaging (MRI) contrast agents and novel contrast enhancement strategies are urgently needed for sensitive and accurate diagnosis. Here we report a strategy to construct a new T1 contrast agent based on the Solomon-Bloembergen-Morgan (SBM) theory. We loaded the ultrasmall gadolinium oxide nanoparticles into worm-like interior channels of mesoporous silica nanospheres (Gd2O3@MSN nanocomposites). This unique structure endows the nanocomposites with geometrical confinement, high molecular tumbling time, and a large coordinated number of water molecules, which results in a significant enhancement of the T1 contrast with longitudinal proton relaxivity (r1) as high as 45.08 mM-1 s-1. Such a high r1 value of Gd2O3@MSN, compared to those of ultrasmall Gd2O3 nanoparticles and gadolinium-based clinical contrast agents, is mainly attributed to the strong geometrical confinement effect. This strategy provides new guidance for developing various high-performance T1 contrast agents for sensitive imaging and disease diagnosis.High-performance magnetic resonance imaging (MRI) contrast agents and novel contrast enhancement strategies are urgently needed for sensitive and accurate diagnosis. Here we report a strategy to construct a new T1 contrast agent based on the Solomon-Bloembergen-Morgan (SBM) theory. We loaded the ultrasmall gadolinium oxide nanoparticles into worm-like interior channels of mesoporous silica nanospheres (Gd2O3@MSN nanocomposites). This unique structure endows the nanocomposites with geometrical confinement, high molecular tumbling time, and a large coordinated number of water molecules, which results in a significant enhancement of the T1 contrast with longitudinal proton relaxivity (r1) as high as 45.08 mM-1 s-1. Such a high r1 value of Gd2O3@MSN, compared to those of ultrasmall Gd2O3 nanoparticles and gadolinium-based clinical contrast agents, is mainly attributed to the strong geometrical confinement effect. This strategy provides new guidance for developing various high-performance T1 contrast agents for sensitive imaging and disease diagnosis. Electronic supplementary information (ESI) available: Supplementary Fig. S1-S6. See DOI: 10.1039/c5nr08402d

  13. Relationship Between Motor Vehicle Collisions and Results of Perimetry, Useful Field of View, and Driving Simulation in Drivers With Glaucoma.

    PubMed

    Tatham, Andrew J; Boer, Erwin R; Gracitelli, Carolina P B; Rosen, Peter N; Medeiros, Felipe A

    2015-05-01

    To examine the relationship between Motor Vehicle Collisions (MVCs) in drivers with glaucoma and standard automated perimetry (SAP), Useful Field of View (UFOV), and driving simulator assessment of divided attention. A cross-sectional study of 153 drivers from the Diagnostic Innovations in Glaucoma Study. All subjects had SAP and divided attention was assessed using UFOV and driving simulation using low-, medium-, and high-contrast peripheral stimuli presented during curve negotiation and car following tasks. Self-reported history of MVCs and average mileage driven were recorded. Eighteen of 153 subjects (11.8%) reported a MVC. There was no difference in visual acuity but the MVC group was older, drove fewer miles, and had worse binocular SAP sensitivity, contrast sensitivity, and ability to divide attention (UFOV and driving simulation). Low contrast driving simulator tasks were the best discriminators of MVC (AUC 0.80 for curve negotiation versus 0.69 for binocular SAP and 0.59 for UFOV). Adjusting for confounding factors, longer reaction times to driving simulator divided attention tasks provided additional value compared with SAP and UFOV, with a 1 standard deviation (SD) increase in reaction time (approximately 0.75 s) associated with almost two-fold increased odds of MVC. Reaction times to low contrast divided attention tasks during driving simulation were significantly associated with history of MVC, performing better than conventional perimetric tests and UFOV. The association between conventional tests of visual function and MVCs in drivers with glaucoma is weak, however, tests of divided attention, particularly using driving simulation, may improve risk assessment.

  14. Thrombomodulin as a marker for vascular tumors. Comparative study with factor VIII and Ulex europaeus I lectin.

    PubMed

    Yonezawa, S; Maruyama, I; Sakae, K; Igata, A; Majerus, P W; Sato, E

    1987-10-01

    Thrombomodulin (TM) is a newly described endothelial cell-associated protein that functions as a potent natural anticoagulant by converting thrombin from a procoagulant protease to an anticoagulant. Various vascular tumors were characterized with immunoperoxidase staining with the use of a polyclonal anti-TM serum. The staining patterns of TM were compared with those of Factor VIII-related antigen (FVIII-RAG) and Ulex europaeus agglutinin-I (UEA-I), which have been used as markers for endothelial cells. The results showed that TM is a specific and a highly sensitive marker for angiosarcomas in comparison with FVIII-RAG or UEA-I. In contrast, UEA-I is more sensitive for benign vascular tumors than TM or FVIII-RAG. The other mesenchymal tumors of nonvascular origin showed negative staining for three endothelial markers. These results indicate that TM is a new specific and sensitive tool for the diagnosis of angiosarcomas.

  15. Performance and Shock Sensitivity Evaluations of Reduced Sensitivity Explosives

    NASA Astrophysics Data System (ADS)

    Bowden, Patrick; Tappan, Bryce; Schmitt, Matthew; Lichthardt, Joseph; Hill, Larry

    2017-06-01

    Making high explosives that possess insensitivity on par with TATB-based plastic bonded explosives (PBXs), while outperforming them, has proven to be a difficult challenge. Many molecules that have challenged TATB have fallen short in either small-scale sensitivity (impact, friction), thermal stability, or possessing a shock sensitivity that is either too high or too low. Recently, an alternative approach to single-molecule-based PBXs has been blending and/or co-crystallizing explosive molecules to address shortcomings of individual components. With this approach in mind, formulations have been prepared containing 1,1-diamino-2,2-dinitroethene (DADNE or FOX-7) or 3,3'-diamino-4,4'-azoxyfurazan (DAAF) with 3-nitro-1,2,4-triazole-5-one (NTO). Detailed characterization of these mixtures has been described in a concurrent study. Here we focus on in depth performance metrics such as cylinder wall expansion and CJ pressure (via free surface velocity) and shock sensitivity, by small-scale gap-testing, were investigated as a function of weight percentages of the components. Results will be contrasted with known insensitive high explosives.

  16. Processing Deficits of Motion of Contrast-Modulated Gratings in Anisometropic Amblyopia

    PubMed Central

    Liu, Zhongjian; Hu, Xiaopeng; Yu, Yong-Qiang; Zhou, Yifeng

    2014-01-01

    Several studies have indicated substantial processing deficits for static second-order stimuli in amblyopia. However, less is known about the perception of second-order moving gratings. To investigate this issue, we measured the contrast sensitivity for second-order (contrast-modulated) moving gratings in seven anisometropic amblyopes and ten normal controls. The measurements were performed with non-equated carriers and a series of equated carriers. For comparison, the sensitivity for first-order motion and static second-order stimuli was also measured. Most of the amblyopic eyes (AEs) showed reduced sensitivity for second-order moving gratings relative to their non-amblyopic eyes (NAEs) and the dominant eyes (CEs) of normal control subjects, even when the detectability of the noise carriers was carefully controlled, suggesting substantial processing deficits of motion of contrast-modulated gratings in anisometropic amblyopia. In contrast, the non-amblyopic eyes of the anisometropic amblyopes were relatively spared. As a group, NAEs showed statistically comparable performance to CEs. We also found that contrast sensitivity for static second-order stimuli was strongly impaired in AEs and part of the NAEs of anisometropic amblyopes, consistent with previous studies. In addition, some amblyopes showed impaired performance in perception of static second-order stimuli but not in that of second-order moving gratings. These results may suggest a dissociation between the processing of static and moving second-order gratings in anisometropic amblyopia. PMID:25409477

  17. Improvement of uncorrected visual acuity and contrast sensitivity with perceptual learning and transcranial random noise stimulation in individuals with mild myopia

    PubMed Central

    Camilleri, Rebecca; Pavan, Andrea; Ghin, Filippo; Battaglini, Luca; Campana, Gianluca

    2014-01-01

    Perceptual learning has been shown to produce an improvement of visual acuity (VA) and contrast sensitivity (CS) both in subjects with amblyopia and refractive defects such as myopia or presbyopia. Transcranial random noise stimulation (tRNS) has proven to be efficacious in accelerating neural plasticity and boosting perceptual learning in healthy participants. In this study, we investigated whether a short behavioral training regime using a contrast detection task combined with online tRNS was as effective in improving visual functions in participants with mild myopia compared to a 2-month behavioral training regime without tRNS (Camilleri et al., 2014). After 2 weeks of perceptual training in combination with tRNS, participants showed an improvement of 0.15 LogMAR in uncorrected VA (UCVA) that was comparable with that obtained after 8 weeks of training with no tRNS, and an improvement in uncorrected CS (UCCS) at various spatial frequencies (whereas no UCCS improvement was seen after 8 weeks of training with no tRNS). On the other hand, a control group that trained for 2 weeks without stimulation did not show any significant UCVA or UCCS improvement. These results suggest that the combination of behavioral and neuromodulatory techniques can be fast and efficacious in improving sight in individuals with mild myopia. PMID:25400610

  18. Polypyrrole coated phase-change contrast agents for sono-photoacoustic imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Li, David S.; Yoon, Soon Joon; Matula, Thomas J.; O'Donnell, Matthew; Pozzo, Lilo D.

    2017-03-01

    A new light and sound sensitive nanoemulsion contrast agent is presented. The agents feature a low boiling point liquid perfluorocarbon core and a broad light spectrum absorbing polypyrrole (PPy) polymer shell. The PPy coated nanoemulsions can reversibly convert from liquid to gas phase upon cavitation of the liquid perfluorocarbon core. Cavitation can be initiated using a sufficiently high intensity acoustic pulse or from heat generation due to light absorption from a laser pulse. The emulsions can be made between 150 and 350 nm in diameter and PPy has a broad optical absorption covering both the visible spectrum and extending into the near-infrared spectrum (peak absorption 1053 nm). The size, structure, and optical absorption properties of the PPy coated nanoemulsions were characterized and compared to PPy nanoparticles (no liquid core) using dynamic light scattering, ultraviolet-visible spectrophotometry, transmission electron microscopy, and small angle X-ray scattering. The cavitation threshold and signal intensity were measured as a function of both acoustic pressure and laser fluence. Overlapping simultaneous transmission of an acoustic and laser pulse can significantly reduce the activation energy of the contrast agents to levels lower than optical or acoustic activation alone. We also demonstrate that simultaneous light and sound cavitation of the agents can be used in a new sono-photoacoustic imaging method, which enables greater sensitivity than traditional photoacoustic imaging.

  19. Pain thresholds, supra-threshold pain and lidocaine sensitivity in patients with erythromelalgia, including the I848Tmutation in NaV 1.7.

    PubMed

    Helås, T; Sagafos, D; Kleggetveit, I P; Quiding, H; Jönsson, B; Segerdahl, M; Zhang, Z; Salter, H; Schmelz, M; Jørum, E

    2017-09-01

    Nociceptive thresholds and supra-threshold pain ratings as well as their reduction upon local injection with lidocaine were compared between healthy subjects and patients with erythromelalgia (EM). Lidocaine (0.25, 0.50, 1.0 or 10 mg/mL) or placebo (saline) was injected intradermally in non-painful areas of the lower arm, in a randomized, double-blind manner, to test the effect on dynamic and static mechanical sensitivity, mechanical pain sensitivity, thermal thresholds and supra-threshold heat pain sensitivity. Heat pain thresholds and pain ratings to supra-threshold heat stimulation did not differ between EM-patients (n = 27) and controls (n = 25), neither did the dose-response curves for lidocaine. Only the subgroup of EM-patients with mutations in sodium channel subunits Na V 1.7, 1.8 or 1.9 (n = 8) had increased lidocaine sensitivity for supra-threshold heat stimuli, contrasting lower sensitivity to strong mechanical stimuli. This pattern was particularly clear in the two patients carrying the Na V 1.7 I848T mutations in whom lidocaine's hyperalgesic effect on mechanical pain sensitivity contrasted more effective heat analgesia. Heat pain thresholds are not sensitized in EM patients, even in those with gain-of-function mutations in Na V 1.7. Differential lidocaine sensitivity was overt only for noxious stimuli in the supra-threshold range suggesting that sensitized supra-threshold encoding is important for the clinical pain phenotype in EM in addition to lower activation threshold. Intracutaneous lidocaine dose-dependently blocked nociceptive sensations, but we did not identify EM patients with particular high lidocaine sensitivity that could have provided valuable therapeutic guidance. Acute pain thresholds and supra-threshold heat pain in controls and patients with erythromelalgia do not differ and have the same lidocaine sensitivity. Acute heat pain thresholds even in EM patients with the Na V 1.7 I848T mutation are normal and only nociceptor sensitivity to intradermal lidocaine is changed. Only in EM patients with mutations in Na V 1.7, 1.8 or 1.9 supra-threshold heat and mechanical pain shows differential lidocaine sensitivity as compared to controls. © 2017 European Pain Federation - EFIC®.

  20. The Effects of Target Orientation on the Dynamic Contrast Sensitivity Function

    DTIC Science & Technology

    1994-01-01

    tests: A comparative evaluation. Journal of Amlied ychology, 50, 460-466. Burg, A. (1971). Vision and driving: A report on research. Human Factors...evaluation. Journal of Applied Ps ogy, 50, 460-466. Burg, A. (1971). Vision and driving: A report on research. Human Factors, 13, 79-87. Campbell, F. W...FUNDING NUMBERS 6. AUTHOR(S)G~ioD A- 0ecoKT, ) 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) 8. PERFORMING ORGANIZATION REPORT NUMBER AFIT Student

  1. Improved word recognition for observers with age-related maculopathies using compensation filters

    NASA Technical Reports Server (NTRS)

    Lawton, Teri B.

    1988-01-01

    A method for improving word recognition for people with age-related maculopathies, which cause a loss of central vision, is discussed. It is found that the use of individualized compensation filters based on an person's normalized contrast sensitivity function can improve word recognition for people with age-related maculopathies. It is shown that 27-70 pct more magnification is needed for unfiltered words compared to filtered words. The improvement in word recognition is positively correlated with the severity of vision loss.

  2. Structural sensitivity of x-ray Bragg projection ptychography to domain patterns in epitaxial thin films

    NASA Astrophysics Data System (ADS)

    Hruszkewycz, S. O.; Zhang, Q.; Holt, M. V.; Highland, M. J.; Evans, P. G.; Fuoss, P. H.

    2016-10-01

    Bragg projection ptychography (BPP) is a coherent diffraction imaging technique capable of mapping the spatial distribution of the Bragg structure factor in nanostructured thin films. Here, we show that, because these images are projections, the structural sensitivity of the resulting images depends on the film thickness and the aspect ratio and orientation of the features of interest and that image interpretation depends on these factors. We model changes in contrast in the BPP reconstructions of simulated PbTiO3 ferroelectric thin films with meandering 180∘ stripe domains as a function of film thickness, discuss their origin, and comment on the implication of these factors on the design of BPP experiments of general nanostructured films.

  3. A simulation of orientation dependent, global changes in camera sensitivity in ECT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bieszk, J.A.; Hawman, E.G.; Malmin, R.E.

    1984-01-01

    ECT promises the abilities to: 1) observe radioisotope distributions in a patient without the summation of overlying activity to reduce contrast, and 2) measure quantitatively these distributions to further and more accurately assess organ function. Ideally, camera-based ECT systems should have a performance that is independent of camera orientation or gantry angle. This study is concerned with ECT quantitation errors that can arise from angle-dependent variations of camera sensitivity. Using simulated phantoms representative of heart and liver sections, the effects of sensitivity changes on reconstructed images were assessed both visually and quantitatively based on ROI sums. The sinogram for eachmore » test image was simulated with 128 linear digitization and 180 angular views. The global orientation-dependent sensitivity was modelled by applying an angular sensitivity dependence to the sinograms of the test images. Four sensitivity variations were studied. Amplitudes of 0% (as a reference), 5%, 10%, and 25% with a costheta dependence were studied as well as a cos2theta dependence with a 5% amplitude. Simulations were done with and without Poisson noise to: 1) determine trends in the quantitative effects as a function of the magnitude of the variation, and 2) to see how these effects are manifested in studies having statistics comparable to clinical cases. For the most realistic sensitivity variation (costheta, 5% ampl.), the ROIs chosen in the present work indicated changes of <0.5% in the noiseless case and <5% for the case with Poisson noise. The effects of statistics appear to dominate any effects due to global, sinusoidal, orientation-dependent sensitivity changes in the cases studied.« less

  4. Spider monkeys (Ateles geoffroyi) are less sensitive to the odor of aliphatic ketones than to the odor of other classes of aliphatic compounds.

    PubMed

    Eliasson, Moa; Hernandez Salazar, Laura Teresa; Laska, Matthias

    2015-10-01

    Aliphatic ketones are widely present in body-borne and food odors of primates. Therefore, we used an operant conditioning paradigm and determined olfactory detection thresholds in four spider monkeys for a homologous series of aliphatic 2-ketones (2-butanone to 2-nonanone) and two of their isomers (3- and 4-heptanone). We found that, with the exception of the two shortest-chained ketones, all animals detected concentrations <1 ppm (parts per million), and with five odorants individual animals even reached threshold values <0.1 ppm. Further, we found a significant correlation between olfactory sensitivity of the spider monkeys and carbon chain length of the 2-ketones which can best be described as a U-shaped function. In contrast, no significant correlation was found between olfactory sensitivity and position of the functional carbonyl group. Across-odorant and across-species comparisons revealed the following: spider monkeys are significantly less sensitive to the odors of aliphatic ketones than to the odor of other classes of aliphatic compounds (1-alcohols, n-aldehydes, n-acetic esters, and n-carboxylic acids) sharing the same carbon length. Spider monkeys do not differ significantly in their olfactory sensitivity for aliphatic ketones from squirrel monkeys and pigtail macaques, but are significantly less sensitive to these odorants compared to human subjects and mice. These findings support the notion that neuroanatomical and genetic properties do not allow for reliable predictions with regard to a species' olfactory sensitivity. Further, we conclude that the frequency of occurrence of a class of odorants in a species' chemical environment does not allow for reliable predictions of the species' olfactory sensitivity. Copyright © 2015 Elsevier Ireland Ltd and the Japan Neuroscience Society. All rights reserved.

  5. Rapid quantification of color vision: the cone contrast test.

    PubMed

    Rabin, Jeff; Gooch, John; Ivan, Douglas

    2011-02-09

    To describe the design, specificity, and sensitivity of the cone contrast test (CCT), a computer-based, cone-specific (L, M, S) contrast sensitivity test for diagnosing type and severity of color vision deficiency (CVD). The CCT presents a randomized series of colored letters visible only to L, M or S cones in decreasing steps of cone contrast to determine L, M, and S letter-recognition thresholds. Sensitivity and specificity were determined by retrospective comparison of CCT scores to anomaloscope and pseudoisochromatic plate (PIP) results in 1446 applicants for pilot training. CVD was detected in 49 (3.4%) of 1446 applicants with hereditary red-green (protan or deutan) CVD detected in 47 (3.5%) of 1359 men and blue-yellow (tritan) in 2 of 1446. In agreement with the anomaloscope, the CCT showed 100% sensitivity for detection and categorization of CVD (40 deutan, 7 protan, 2 tritan). PIP testing showed lower sensitivity (80% detected; 20% missed) due in part to the applicant's prior experience and/or pretest preparation. CCT specificity for confirming normal color vision was 100% for L and M cone tests and 99.8% for S cones. The CCT has sensitivity and specificity comparable to anomaloscope testing and exceeds PIP sensitivity in practiced observers. The CCT provides a rapid (6 minutes), clinically expedient, measure of color vision for quantifying normal color performance, diagnosing type and severity of hereditary deficiency, and detection of acquired sensitivity loss due to ocular, neurologic, and/or systemic disease, as well as injury and physiological stressors, such as altitude and fatigue.

  6. Comparison between esophagography and chest computed tomography for evaluation of leaks after esophagectomy and gastric pull-through.

    PubMed

    Lantos, Joshua E; Levine, Marc S; Rubesin, Stephen E; Lau, Charles T; Torigian, Drew A

    2013-03-01

    To assess the diagnostic performance of esophagography and chest computed tomography (CT) for detecting leaks after esophagectomy and gastric pull-through. Our database revealed 29 patients who had undergone esophagography and chest CT after esophagectomy. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for postoperative leaks were determined for esophagography and CT, separately and combined, on the basis of a retrospective image review. Patients were also stratified for esophagograms with water-soluble contrast alone versus water-soluble contrast and high-density barium and for CT with and without oral contrast. Our findings were retrospectively compared with those reported at initial image interpretation. Clinically relevant leaks were present in 14 (48%) of 29 patients after esophagectomy. Esophagography had a sensitivity of 79%, specificity of 73%, PPV of 73%, and NPV of 79% for detecting leaks, whereas CT had a sensitivity of 86%, specificity of 33%, PPV of 55%, and NPV of 71% and esophagography and CT combined had a sensitivity of 100%, specificity of 27%, PPV of 56%, and NPV of 100%. The sensitivity of esophagography increased with high-density barium, whereas the sensitivity of CT was the same with and without oral contrast agent. Finally, esophagography and CT were seen to have a higher sensitivity and lower specificity on retrospective review compared with the results reported at initial image interpretation. Esophagography had a slightly lower sensitivity and substantially higher specificity compared with CT for detecting leaks after esophagectomy, whereas esophagography and CT combined had a sensitivity of 100% for detecting leaks. Therefore, postoperative leaks can be excluded with confidence after esophagectomy when both tests are negative.

  7. Ultrasonic Analysis of Peptide- and Antibody-Targeted Microbubble Contrast Agents for Molecular Imaging of αvβ3-Expressing Cells

    PubMed Central

    Dayton, Paul A.; Pearson, David; Clark, Jarrod; Simon, Scott; Schumann, Patricia A.; Zutshi, Reena; Matsunaga, Terry O.; Ferrara, Katherine W.

    2008-01-01

    The goal of targeted ultrasound contrast agents is to significantly and selectively enhance the detection of a targeted vascular site. In this manuscript, three distinct contrast agents targeted to the αvβ3 integrin are examined. The αvβ3 integrin has been shown to be highly expressed on metastatic tumors and endothelial cells during neovascularization, and its expression has been shown to correlate with tumor grade. Specific adhesion of these contrast agents to αvβ3-expressing cell monolayers is demonstrated in vitro, and compared with that of nontargeted agents. Acoustic studies illustrate a backscatter amplitude increase from monolayers exposed to the targeted contrast agents of up to 13-fold (22 dB) relative to enhancement due to control bubbles. A linear dependence between the echo amplitude and bubble concentration was observed for bound agents. The decorrelation of the echo from adherent targeted agents is observed over successive pulses as a function of acoustic pressure and bubble density. Frequency–domain analysis demonstrates that adherent targeted bubbles exhibit high-amplitude narrowband echo components, in contrast to the primarily wideband response from free microbubbles. Results suggest that adherent targeted contrast agents are differentiable from free-floating microbubbles, that targeted contrast agents provide higher sensitivity in the detection of angiogenesis, and that conventional ultrasound imaging techniques such as signal subtraction or decorrelation detection can be used to detect integrin-expressing vasculature with sufficient signal-to-noise. PMID:15296677

  8. In vivo imaging of human oral hard and soft tissues by polarization-sensitive optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Walther, Julia; Golde, Jonas; Kirsten, Lars; Tetschke, Florian; Hempel, Franz; Rosenauer, Tobias; Hannig, Christian; Koch, Edmund

    2017-12-01

    Since optical coherence tomography (OCT) provides three-dimensional high-resolution images of biological tissue, the benefit of polarization contrast in the field of dentistry is highlighted in this study. Polarization-sensitive OCT (PS OCT) with phase-sensitive recording is used for imaging dental and mucosal tissues in the human oral cavity in vivo. An enhanced polarization contrast of oral structures is reached by analyzing the signals of the co- and crosspolarized channels of the swept source PS OCT system quantitatively with respect to reflectivity, retardation, optic axis orientation, and depolarization. The calculation of these polarization parameters enables a high tissue-specific contrast imaging for the detailed physical interpretation of human oral hard and soft tissues. For the proof-of-principle, imaging of composite restorations and mineralization defects at premolars as well as gingival, lingual, and labial oral mucosa was performed in vivo within the anterior oral cavity. The achieved contrast-enhanced results of the investigated human oral tissues by means of polarization-sensitive imaging are evaluated by the comparison with conventional intensity-based OCT.

  9. Persistence and storage of activity patterns in spiking recurrent cortical networks: modulation of sigmoid signals by after-hyperpolarization currents and acetylcholine

    PubMed Central

    Palma, Jesse; Grossberg, Stephen; Versace, Massimiliano

    2012-01-01

    Many cortical networks contain recurrent architectures that transform input patterns before storing them in short-term memory (STM). Theorems in the 1970's showed how feedback signal functions in rate-based recurrent on-center off-surround networks control this process. A sigmoid signal function induces a quenching threshold below which inputs are suppressed as noise and above which they are contrast-enhanced before pattern storage. This article describes how changes in feedback signaling, neuromodulation, and recurrent connectivity may alter pattern processing in recurrent on-center off-surround networks of spiking neurons. In spiking neurons, fast, medium, and slow after-hyperpolarization (AHP) currents control sigmoid signal threshold and slope. Modulation of AHP currents by acetylcholine (ACh) can change sigmoid shape and, with it, network dynamics. For example, decreasing signal function threshold and increasing slope can lengthen the persistence of a partially contrast-enhanced pattern, increase the number of active cells stored in STM, or, if connectivity is distance-dependent, cause cell activities to cluster. These results clarify how cholinergic modulation by the basal forebrain may alter the vigilance of category learning circuits, and thus their sensitivity to predictive mismatches, thereby controlling whether learned categories code concrete or abstract features, as predicted by Adaptive Resonance Theory. The analysis includes global, distance-dependent, and interneuron-mediated circuits. With an appropriate degree of recurrent excitation and inhibition, spiking networks maintain a partially contrast-enhanced pattern for 800 ms or longer after stimuli offset, then resolve to no stored pattern, or to winner-take-all (WTA) stored patterns with one or multiple winners. Strengthening inhibition prolongs a partially contrast-enhanced pattern by slowing the transition to stability, while strengthening excitation causes more winners when the network stabilizes. PMID:22754524

  10. Sight restoration after congenital blindness does not reinstate alpha oscillatory activity in humans

    PubMed Central

    Bottari, Davide; Troje, Nikolaus F.; Ley, Pia; Hense, Marlene; Kekunnaya, Ramesh; Röder, Brigitte

    2016-01-01

    Functional brain development is characterized by sensitive periods during which experience must be available to allow for the full development of neural circuits and associated behavior. Yet, only few neural markers of sensitive period plasticity in humans are known. Here we employed electroencephalographic recordings in a unique sample of twelve humans who had been blind from birth and regained sight through cataract surgery between four months and 16 years of age. Two additional control groups were tested: a group of visually impaired individuals without a history of total congenital blindness and a group of typically sighted individuals. The EEG was recorded while participants performed a visual discrimination task involving intact and scrambled biological motion stimuli. Posterior alpha and theta oscillations were evaluated. The three groups showed indistinguishable behavioral performance and in all groups evoked theta activity varied with biological motion processing. By contrast, alpha oscillatory activity was significantly reduced only in individuals with a history of congenital cataracts. These data document on the one hand brain mechanisms of functional recovery (related to theta oscillations) and on the other hand, for the first time, a sensitive period for the development of alpha oscillatory activity in humans. PMID:27080158

  11. Thin films composed of multiwalled carbon nanotubes, gold nanoparticles and myoglobin for humidity detection at room temperature.

    PubMed

    Qi, Zhi-mei; Wei, Mingdeng; Honma, Itaru; Zhou, Haoshen

    2007-02-02

    Optically transparent and electrically conductive nanocomposite thin films consisting of multiwalled carbon nanotubes (MWCNTs), gold nanoparticles (GNPs) and myoglobin molecules that glue GNPs and MWCNTs together are fabricated for the first time on glass substrates from aqueous solution. The nanocomposite thin film is capable of varying its resistance, impedance or optical transmittance at room temperature in response to changes in ambient humidity. The conductometric sensitivity to relative humidity (RH) of the nanocomposite thin film is compared with those of the pure and Mb-functionalized MWCNT layers. The pure MWCNT layer shows a small increase in its resistance with increasing RH due to the effect of p-type semiconducting nanotubes present in the film. In contrast, a four times higher sensitivity to RH is observed for both the nanocomposite and Mb-functionalized MWCNT thin films. The sensitivity enhancement is attributable to swelling of the thin films induced by water absorption in the presence of Mb molecules, which increases the inter-nanotube spacing and thereby causes a further increase of the film resistance. A humidity change as low as DeltaRH=0.3 % has been readily detected by conductometry using the nanocomposite thin film.

  12. Expressing negative emotions to children: Mothers' aversion sensitivity and children's adjustment.

    PubMed

    Moed, Anat; Dix, Theodore; Anderson, Edward R; Greene, Shannon M

    2017-03-01

    Research is unclear about when expressing negative emotions to children performs valuable socialization and regulatory functions and when, instead, it undermines children's adjustment. In this study, we isolated 1 kind of negative expression to test the aversion sensitivity hypothesis: that rapid increases in mothers' negativity as a function of increases in the aversiveness of children's behavior are uniquely problematic for children. During multiple assessments of a divorcing sample over 2 years (N = 284), 12-min interactions between mothers and their 4- to 11-year-old children were recorded. Forty-seven observed child behaviors were ranked from low to high aversive. Within-dyad changes demonstrated that mothers' general negativity-their tendency to express negative emotion at high rates-was unrelated to children's adjustment. In contrast, mothers' aversion-focused negativity-their tendency to increase negative emotional expression rapidly as the aversiveness of children's behavior increased-predicted children's poor social competence, poor emotion regulation, and externalizing behavior problems at the next assessment. The findings suggest that negative expression that reflects mothers' affective sensitivity to aversive child behavior may promote interaction patterns and adaptations in children that are particularly likely to place children at risk for adjustment problems. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  13. Postnatal Day 2 to 11 Constitutes a 5-HT-Sensitive Period Impacting Adult mPFC Function

    PubMed Central

    Rebello, Tahilia J.; Yu, Qinghui; Goodfellow, Nathalie M.; Caffrey Cagliostro, Martha K.; Teissier, Anne; Morelli, Emanuela; Demireva, Elena Y.; Chemiakine, Alexei; Rosoklija, Gorazd B.; Dwork, Andrew J.; Lambe, Evelyn K.; Ansorge, Mark S.

    2014-01-01

    Early-life serotonin [5-hydroxytryptamine (5-HT)] signaling modulates brain development, which impacts adult behavior, but 5-HT-sensitive periods, neural substrates, and behavioral consequences remain poorly understood. Here we identify the period ranging from postnatal day 2 (P2) to P11 as 5-HT sensitive, with 5-HT transporter (5-HTT) blockade increasing anxiety- and depression-like behavior, and impairing fear extinction learning and memory in adult mice. Concomitantly, P2–P11 5-HTT blockade causes dendritic hypotrophy and reduced excitability of infralimbic (IL) cortex pyramidal neurons that normally promote fear extinction. By contrast, the neighboring prelimbic (PL) pyramidal neurons, which normally inhibit fear extinction, become more excitable. Excitotoxic IL but not PL lesions in adult control mice reproduce the anxiety-related phenotypes. These findings suggest that increased 5-HT signaling during P2–P11 alters adult mPFC function to increase anxiety and impair fear extinction, and imply a differential role for IL and PL neurons in regulating affective behaviors. Together, our results support a developmental mechanism for the etiology and pathophysiology of affective disorders and fear-related behaviors. PMID:25209278

  14. Mr 40,000 and Mr 39,000 pertussis toxin substrates are increased in surgically denervated dog ventricular myocardium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hershberger, R.E.; Feldman, A.M.; Anderson, F.L.

    1991-04-01

    To test the general hypothesis that cardiac innervation may participate in myocardial G protein regulation, we examined the effects of complete intrapericardial surgical denervation or sham operation in dogs. In particulate fractions of dog left ventricular (LV) myocardium harvested 28-33 days after denervation or sham operation, Mr 40,000 and Mr 39,000 pertussis toxin-sensitive substrates (G proteins) were increased by 31% (1.31 +/- 0.084 vs 1.00 +/- 0.058 OD, arbitrary units, p less than 0.01) and 40% (1.40 +/- 0.117 vs. 1.000 +/- 0.084 OD, arbitrary units, p less than 0.02), respectively, as compared with sham-operated controls. The Mr 40,000 pertussismore » toxin-sensitive band comigrated with a pertussis toxin-sensitive substrate in human erythrocyte membranes known to contain an alpha Gi species. In these same preparations basal, GTP and GppNHp stimulated adenylate cyclase activities were decreased in denervated heart by 20, 26, and 19%, respectively, consistent with increased activity of an inhibitory G protein. In contrast, Gs function was not altered, because cyc(-) membranes reconstituted with membrane extracts and fluoride and beta-receptor-stimulated adenylate cyclase activity were not different between groups. Furthermore, adenylate cyclase catalytic subunit function as assessed with forskolin and manganese stimulation was not different between preparations of control and denervated heart. We conclude that in preparations of surgically denervated dog myocardium Mr 40,000 and Mr 39,000 pertussis toxin-sensitive G proteins are increased by 31 and 40%, respectively, and that functional alterations in adenylate cyclase activity exist, consistent with increased inhibitory G-protein function.« less

  15. [Preoperative imaging/operation planning for liver surgery].

    PubMed

    Schoening, W N; Denecke, T; Neumann, U P

    2015-12-01

    The currently established standard for planning liver surgery is multistage contrast media-enhanced multidetector computed tomography (CM-CT), which as a rule enables an appropriate resection planning, e.g. a precise identification and localization of primary and secondary liver tumors as well as the anatomical relation to extrahepatic and/or intrahepatic vascular and biliary structures. Furthermore, CM-CT enables the measurement of tumor volume, total liver volume and residual liver volume after resection. Under the condition of normal liver function a residual liver volume of 25 % is nowadays considered sufficient and safe. Recent studies in patients with liver metastases of colorectal cancer showed a clear staging advantage of contrast media-enhanced magnetic resonance imaging (CM-MRI) versus CM-CT. In addition, most recent data showed that the use of liver-specific MRI contrast media further increases the sensitivity and specificity of detection of liver metastases. This imaging technology seems to lead closer to the ideal "one stop shopping" diagnostic tool in preoperative planning of liver resection.

  16. Metabolomic Profiling of Amino Acids and β-Cell Function Relative to Insulin Sensitivity in Youth

    PubMed Central

    Michaliszyn, Sara F.; Sjaarda, Lindsey A.; Mihalik, Stephanie J.; Lee, SoJung; Bacha, Fida; Chace, Donald H.; De Jesus, Victor R.; Vockley, Jerry

    2012-01-01

    Context: In longitudinal studies of adults, elevated amino acid (AA) concentrations predicted future type 2 diabetes mellitus (T2DM). Objective: The aim of the present investigation was to examine whether increased plasma AA concentrations are associated with impaired β-cell function relative to insulin sensitivity [i.e. disposition index (DI)], a predictor of T2DM development. Design, Setting, and Participants: Metabolomic analysis for fasting plasma AAs was performed by tandem mass spectrometry in 139 normal-weight and obese adolescents with and without dysglycemia. First-phase insulin secretion was evaluated by a hyperglycemic (∼225 mg/dl) clamp and insulin sensitivity by a hyperinsulinemic-euglycemic clamp. DI was calculated as the product of first-phase insulin and insulin sensitivity. Results: DI was positively associated with branched-chain AAs (leucine/isoleucine and valine; r = 0.27 and 0.29, P = 0.001), neutrally transported AAs (phenylalanine and methionine; r = 0.30 and 0.35, P < 0.001), basic AAs (histidine and arginine; r = 0.28 and 0.23, P ≤ 0.007), serine (r = 0.35, P < 0.001), glycine (r = 0.26, P = 0.002), and branched-chain AAs-derived intermediates C3, C4, and C5 acylcarnitine (range r = 0.18–0.19, P ≤ 0.04). Conclusion: In youth, increased plasma AA concentrations are not associated with a heightened metabolic risk profile for T2DM; rather, they are positively associated with β-cell function relative to insulin sensitivity. These contrasting observations between adults and youth may be a reflection of developmental differences along the lifespan dependent on the combined impact of the aging process together with the impact of progressive obesity. PMID:22977272

  17. Functional and Morphological Correlations before and after Video-Documented 23-Gauge Pars Plana Vitrectomy with Membrane and ILM Peeling in Patients with Macular Pucker.

    PubMed

    Mayer, Wolfgang J; Fazekas, Clara; Schumann, Ricarda; Wolf, Armin; Compera, Denise; Kampik, Anselm; Haritoglou, Christos

    2015-01-01

    Purpose. To assess functional and morphological alterations following video-documented surgery for epiretinal membranes. Methods. Forty-two patients underwent video-documented 23-gauge vitrectomy with peeling of epiretinal (ERM) and inner limiting membrane (ILM). Patient assessment was performed before and 3 and 6 months including best corrected visual acuity (BCVA), slit lamp biomicroscopy, SD-OCT, and central 2° and 18° microperimetry. In addition, all video-documented areas of peeling on the retinal surface were evaluated postoperatively using an additional focal 2° microperimetry. Retinal sensitivity and BCVA were correlated with morphological changes (EZ and ELM) in the foveal region and in regions of membrane peeling. Results. Overall, BCVA increased from 0.6 (±0.2) to 0.2 (±0.2) logMAR after 6 months with an increase in retinal sensitivity (17.9 ± 2.7 dB to 26.8 ± 3.1 dB, p < 0.01). We observed a significant correlation between the integrity of the EZ but not of the ELM and the retinal sensitivity, overall and in peeling areas (p < 0.05). However, no significant correlation between alterations in the area of peeling and overall retinal sensitivity regarding visual acuity gain could be observed after 6 months (p > 0.05). In contrast, overall postoperative retinal sensitivity was significantly decreased in patients with a visual acuity gain lower than 2 lines (p < 0.05) correlating with EZ defects seen in OCT. Conclusions. Mechanical trauma of epiretinal membrane and ILM peeling due to the use of intraocular forceps may affect the outer retinal structure. Nevertheless, these changes seem to have no significant impact on postoperative functional outcome.

  18. Sex Reversal in C57BL/6J XY Mice Caused by Increased Expression of Ovarian Genes and Insufficient Activation of the Testis Determining Pathway

    PubMed Central

    Correa, Stephanie M.; Washburn, Linda L.; Kahlon, Ravi S.; Musson, Michelle C.; Bouma, Gerrit J.; Eicher, Eva M.; Albrecht, Kenneth H.

    2012-01-01

    Sex reversal can occur in XY humans with only a single functional WT1 or SF1 allele or a duplication of the chromosome region containing WNT4. In contrast, XY mice with only a single functional Wt1, Sf1, or Wnt4 allele, or mice that over-express Wnt4 from a transgene, reportedly are not sex-reversed. Because genetic background plays a critical role in testis differentiation, particularly in C57BL/6J (B6) mice, we tested the hypothesis that Wt1, Sf1, and Wnt4 are dosage sensitive in B6 XY mice. We found that reduced Wt1 or Sf1 dosage in B6 XYB6 mice impaired testis differentiation, but no ovarian tissue developed. If, however, a YAKR chromosome replaced the YB6 chromosome, these otherwise genetically identical B6 XY mice developed ovarian tissue. In contrast, reduced Wnt4 dosage increased the amount of testicular tissue present in Sf1+/− B6 XYAKR, Wt1+/− B6 XYAKR, B6 XYPOS, and B6 XYAKR fetuses. We propose that Wt1B6 and Sf1B6 are hypomorphic alleles of testis-determining pathway genes and that Wnt4B6 is a hypermorphic allele of an ovary-determining pathway gene. The latter hypothesis is supported by the finding that expression of Wnt4 and four other genes in the ovary-determining pathway are elevated in normal B6 XX E12.5 ovaries. We propose that B6 mice are sensitive to XY sex reversal, at least in part, because they carry Wt1B6 and/or Sf1B6 alleles that compromise testis differentiation and a Wnt4B6 allele that promotes ovary differentiation and thereby antagonizes testis differentiation. Addition of a “weak” Sry allele, such as the one on the YPOS chromosome, to the sensitized B6 background results in inappropriate development of ovarian tissue. We conclude that Wt1, Sf1, and Wnt4 are dosage-sensitive in mice, this dosage-sensitivity is genetic background-dependant, and the mouse strains described here are good models for the investigation of human dosage-sensitive XY sex reversal. PMID:22496664

  19. Gain-of-function mutations of fem-3, a sex-determination gene in Caenorhabditis elegans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barton, M.K.; Schedl, T.B.; Kimble, J.

    1987-01-01

    The authors have isolated nine gain-of-function (gf) alleles of the sex-determination gene fem-3 as suppressors of feminizing mutations in fem-1 and fem-2. The wild type fem-3 gene is needed for spermatogenesis in XX self-fertilizing hermaphrodites and for male development in both soma and germ line of XO animals. Loss-of-function alleles of fem-3 transform XX and XO animals into females (spermless hermaphrodites). In contrast, fem-3 (gf) alleles masculinize only one tissue, the hermaphrodite germ line. Thus, XX fem-3 (gf) mutant animals have a normal hermaphrodite soma, but the germ line produces a vast excess of sperm and no oocytes. All ninemore » fem-3 (gf) alleles are temperature sensitive. The temperature-sensitive period is from late L4 to early adult, a period just preceding the first signs of oogenesis. The finding of gain-of-function alleles which confer a phenotype opposite to that of loss-of-function alleles supports the idea that fem-3 plays a critical role in germ-line sex determination. Furthermore, the germ-line specificity of the fem-3 (gf) mutant phenotype and the late temperature-sensitive period suggest that, in the wild-type XX hermaphrodite, fem-3 is negatively regulated so that the hermaphrodite stops making sperm and starts making oocytes. Temperature shift experiments also show that, in the germ line, sexual commitment appears to be a continuing process. Spermatogenesis can resume even after oogenesis has begun, and oogenesis can be initiated much later than normal.« less

  20. Polarization Dependent Bulk-sensitive Valence Band Photoemission Spectroscopy and Density Functional Theory Calculations: Part I. 3d Transition Metals

    NASA Astrophysics Data System (ADS)

    Ueda, Shigenori; Hamada, Ikutaro

    2017-12-01

    The X-ray polarization dependent valence band HAXPES spectra of 3d transition metals (TMs) of Ti-Zn were measured to investigate the orbital resolved electronic structures by utilizing that the fact the photoionization cross-section of the atomic orbitals strongly depends on the experimental geometry. We have calculated the HAXPES spectra, which correspond to the cross-section weighted densities of states (CSW-DOSs), where the DOSs were obtained by the density functional theory calculations, and we have determined the relative photoionization cross-sections of the 4s and 4p orbitals to the 3d orbital in the 3d TMs. The experimentally obtained bulk-sensitive 3d and 4s DOSs were good agreement with the calculated DOSs in Ti, V, Cr, and Cu. In contrast, the deviations between the experimental and calculated 3d DOSs for Mn, Fe, Co, Ni were found, suggesting that the electron correlation plays an important role in the electronic structures for these materials.

  1. Large effects of consumer offense on ecosystem structure and function.

    PubMed

    Chislock, Michael F; Sarnelle, Orlando; Olsen, Brianna K; Doster, Enrique; Wilson, Alan E

    2013-11-01

    Study of the role of within-species adaptation in ecological dynamics has focused largely on prey adaptations that reduce consumption risk (prey defense). Few, if any, studies have examined how consumer adaptations to overcome prey defenses (consumer offense) affect ecosystem structure and function. We manipulated two sets of genotypes of a planktonic herbivore (Daphnia pulicaria) in a highly productive ecosystem with abundant toxic prey (cyanobacteria). The two sets of consumer genotypes varied widely in their tolerance of toxic cyanobacteria in the diet (i.e., sensitive vs. tolerant). We found a large effect of tolerant D. pulicaria on phytoplankton biomass and gross primary productivity but no effect of sensitive genotypes, this result stemming from genotype-specific differences in population growth in the presence of toxic prey. The former effect was as large as effects seen in previous Daphnia manipulations at similar productivity levels. Thus, we demonstrated that the effect of consumer genotypes with contrasting offensive adaptations was as large as the effect of consumer presence/absence.

  2. Localization and function of ATP-sensitive potassium channels in human skeletal muscle.

    PubMed

    Nielsen, Jens Jung; Kristensen, Michael; Hellsten, Ylva; Bangsbo, Jens; Juel, Carsten

    2003-02-01

    The present study investigated the localization of ATP-sensitive K+ (KATP) channels in human skeletal muscle and the functional importance of these channels for human muscle K+ distribution at rest and during muscle activity. Membrane fractionation based on the giant vesicle technique or the sucrose-gradient technique in combination with Western blotting demonstrated that the KATP channels are mainly located in the sarcolemma. This localization was confirmed by immunohistochemical measurements. With the microdialysis technique, it was demonstrated that local application of the KATP channel inhibitor glibenclamide reduced (P < 0.05) interstitial K+ at rest from approximately 4.5 to 4.0 mM, whereas the concentration in the control leg remained constant. Glibenclamide had no effect on the interstitial K+ accumulation during knee-extensor exercise at a power output of 60 W. In contrast to in vitro conditions, the present study demonstrated that under in vivo conditions the KATP channels are active at rest and contribute to the accumulation of interstitial K+.

  3. Microglial brain region-dependent diversity and selective regional sensitivities to ageing

    PubMed Central

    Grabert, Kathleen; Michoel, Tom; Karavolos, Michail H; Clohisey, Sara; Baillie, J Kenneth; Stevens, Mark P; Freeman, Tom C; Summers, Kim M; McColl, Barry W

    2015-01-01

    Microglia play critical roles in neural development, homeostasis and neuroinflammation and are increasingly implicated in age-related neurological dysfunction. Neurodegeneration often occurs in disease-specific spatially-restricted patterns, the origins of which are unknown. We performed the first genome-wide analysis of microglia from discrete brain regions across the adult lifespan of the mouse and reveal that microglia have distinct region-dependent transcriptional identities and age in a regionally variable manner. In the young adult brain, differences in bioenergetic and immunoregulatory pathways were the major sources of heterogeneity and suggested that cerebellar and hippocampal microglia exist in a more immune vigilant state. Immune function correlated with regional transcriptional patterns. Augmentation of the distinct cerebellar immunophenotype and a contrasting loss in distinction of the hippocampal phenotype among forebrain regions were key features during ageing. Microglial diversity may enable regionally localised homeostatic functions but could also underlie region-specific sensitivities to microglial dysregulation and involvement in age-related neurodegeneration. PMID:26780511

  4. Dissecting out conscious and unconscious memory (sub)processes within the human medial temporal lobe.

    PubMed

    Grunwald, T; Pezer, N; Münte, T F; Kurthen, M; Lehnertz, K; Van Roost, D; Fernández, G; Kutas, M; Elger, C E

    2003-11-01

    The human medial temporal lobe (MTL) system mediates memories that can be consciously recollected. However, the specific natures of the individual contributions of its various subregions to conscious memory processes remain equivocal. Here we show a functional dissociation between the hippocampus proper and the parahippocampal region in conscious and unconscious memory as revealed by invasive recordings of limbic event-related brain potentials recorded during explicit and implicit word recognition: Only hippocampal and not parahippocampal neural activity exhibits a sensitivity to the implicit versus explicit nature of the recognition memory task. Moreover, only within the hippocampus proper do the neural responses to repeated words differ not only from those to new words but also from each other as a function of recognition success. By contrast parahippocampal (rhinal) responses are sensitive to repetition independent of conscious recognition. These findings thus demonstrate that it is the hippocampus proper among the MTL structures that is specifically engaged during conscious memory processes.

  5. Influence of neurobehavioral incentive valence and magnitude on alcohol drinking behavior

    PubMed Central

    Joseph, Jane E.; Zhu, Xun; Corbly, Christine R.; DeSantis, Stacia; Lee, Dustin C.; Baik, Grace; Kiser, Seth; Jiang, Yang; Lynam, Donald R.; Kelly, Thomas H.

    2014-01-01

    The monetary incentive delay (MID) task is a widely used probe for isolating neural circuitry in the human brain associated with incentive motivation. In the present functional magnetic resonance imaging (fMRI) study, 82 young adults, characterized along dimensions of impulsive sensation seeking, completed a MID task. fMRI and behavioral incentive functions were decomposed into incentive valence and magnitude parameters, which were used as predictors in linear regression to determine whether mesolimbic response is associated with problem drinking and recent alcohol use. Alcohol use was best explained by higher fMRI response to anticipation of losses and feedback on high gains in the thalamus. In contrast, problem drinking was best explained by reduced sensitivity to large incentive values in meso-limbic regions in the anticipation phase and increased sensitivity to small incentive values in the dorsal caudate nucleus in the feedback phase. Altered fMRI responses to monetary incentives in mesolimbic circuitry, particularly those alterations associated with problem drinking, may serve as potential early indicators of substance abuse trajectories. PMID:25261001

  6. Calibration of a Spatial-Temporal Discrimination Model from Forward, Simultaneous, and Backward Masking

    NASA Technical Reports Server (NTRS)

    Ahumada, Albert J.; Beard, B. L.; Stone, Leland (Technical Monitor)

    1997-01-01

    We have been developing a simplified spatial-temporal discrimination model similar to our simplified spatial model in that masking is assumed to be a function of the local visible contrast energy. The overall spatial-temporal sensitivity of the model is calibrated to predict the detectability of targets on a uniform background. To calibrate the spatial-temporal integration functions that define local visible contrast energy, spatial-temporal masking data are required. Observer thresholds were measured (2IFC) for the detection of a 12 msec target stimulus in the presence of a 700 msec mask. Targets were 1, 3 or 9 c/deg sine wave gratings. Masks were either one of these gratings or two of them combined. The target was presented in 17 temporal positions with respect to the mask, including positions before, during and after the mask. Peak masking was found near mask onset and offset for 1 and 3 c/deg targets, while masking effects were more nearly uniform during the mask for the 9 c/deg target. As in the purely spatial case, the simplified model can not predict all the details of masking as a function of masking component spatial frequencies, but overall the prediction errors are small.

  7. Paradoxical psychometric functions (“swan functions”) are explained by dilution masking in four stimulus dimensions

    PubMed Central

    Baker, Daniel H.; Meese, Tim S.; Georgeson, Mark A.

    2013-01-01

    The visual system dissects the retinal image into millions of local analyses along numerous visual dimensions. However, our perceptions of the world are not fragmentary, so further processes must be involved in stitching it all back together. Simply summing up the responses would not work because this would convey an increase in image contrast with an increase in the number of mechanisms stimulated. Here, we consider a generic model of signal combination and counter-suppression designed to address this problem. The model is derived and tested for simple stimulus pairings (e.g. A + B), but is readily extended over multiple analysers. The model can account for nonlinear contrast transduction, dilution masking, and signal combination at threshold and above. It also predicts nonmonotonic psychometric functions where sensitivity to signal A in the presence of pedestal B first declines with increasing signal strength (paradoxically dropping below 50% correct in two-interval forced choice), but then rises back up again, producing a contour that follows the wings and neck of a swan. We looked for and found these “swan” functions in four different stimulus dimensions (ocularity, space, orientation, and time), providing some support for our proposal. PMID:23799185

  8. Long-term exposure to abnormal glucose levels alters drug metabolism pathways and insulin sensitivity in primary human hepatocytes

    NASA Astrophysics Data System (ADS)

    Davidson, Matthew D.; Ballinger, Kimberly R.; Khetani, Salman R.

    2016-06-01

    Hyperglycemia in type 2 diabetes mellitus has been linked to non-alcoholic fatty liver disease, which can progress to inflammation, fibrosis/cirrhosis, and hepatocellular carcinoma. Understanding how chronic hyperglycemia affects primary human hepatocytes (PHHs) can facilitate the development of therapeutics for these diseases. Conversely, elucidating the effects of hypoglycemia on PHHs may provide insights into how the liver adapts to fasting, adverse diabetes drug reactions, and cancer. In contrast to declining PHH monocultures, micropatterned co-cultures (MPCCs) of PHHs and 3T3-J2 murine embryonic fibroblasts maintain insulin-sensitive glucose metabolism for several weeks. Here, we exposed MPCCs to hypo-, normo- and hyperglycemic culture media for ~3 weeks. While albumin and urea secretion were not affected by glucose level, hypoglycemic MPCCs upregulated CYP3A4 enzyme activity as compared to other glycemic states. In contrast, hyperglycemic MPCCs displayed significant hepatic lipid accumulation in the presence of insulin, while also showing decreased sensitivity to insulin-mediated inhibition of glucose output relative to a normoglycemic control. In conclusion, we show for the first time that PHHs exposed to hypo- and hyperglycemia can remain highly functional, but display increased CYP3A4 activity and selective insulin resistance, respectively. In the future, MPCCs under glycemic states can aid in novel drug discovery and mechanistic investigations.

  9. Wavefront-Guided Versus Wavefront-Optimized Photorefractive Keratectomy: Visual and Military Task Performance.

    PubMed

    Ryan, Denise S; Sia, Rose K; Stutzman, Richard D; Pasternak, Joseph F; Howard, Robin S; Howell, Christopher L; Maurer, Tana; Torres, Mark F; Bower, Kraig S

    2017-01-01

    To compare visual performance, marksmanship performance, and threshold target identification following wavefront-guided (WFG) versus wavefront-optimized (WFO) photorefractive keratectomy (PRK). In this prospective, randomized clinical trial, active duty U.S. military Soldiers, age 21 or over, electing to undergo PRK were randomized to undergo WFG (n = 27) or WFO (n = 27) PRK for myopia or myopic astigmatism. Binocular visual performance was assessed preoperatively and 1, 3, and 6 months postoperatively: Super Vision Test high contrast, Super Vision Test contrast sensitivity (CS), and 25% contrast acuity with night vision goggle filter. CS function was generated testing at five spatial frequencies. Marksmanship performance in low light conditions was evaluated in a firing tunnel. Target detection and identification performance was tested for probability of identification of varying target sets and probability of detection of humans in cluttered environments. Visual performance, CS function, marksmanship, and threshold target identification demonstrated no statistically significant differences over time between the two treatments. Exploratory regression analysis of firing range tasks at 6 months showed no significant differences or correlations between procedures. Regression analysis of vehicle and handheld probability of identification showed a significant association with pretreatment performance. Both WFG and WFO PRK results translate to excellent and comparable visual and military performance. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.

  10. Deciphering complex, functional structures with synchrotron-based absorption and phase contrast tomographic microscopy

    NASA Astrophysics Data System (ADS)

    Stampanoni, M.; Reichold, J.; Weber, B.; Haberthür, D.; Schittny, J.; Eller, J.; Büchi, F. N.; Marone, F.

    2010-09-01

    Nowadays, thanks to the high brilliance available at modern, third generation synchrotron facilities and recent developments in detector technology, it is possible to record volumetric information at the micrometer scale within few minutes. High signal-to-noise ratio, quantitative information on very complex structures like the brain micro vessel architecture, lung airways or fuel cells can be obtained thanks to the combination of dedicated sample preparation protocols, in-situ acquisition schemes and cutting-edge imaging analysis instruments. In this work we report on recent experiments carried out at the TOMCAT beamline of the Swiss Light Source [1] where synchrotron-based tomographic microscopy has been successfully used to obtain fundamental information on preliminary models for cerebral fluid flow [2], to provide an accurate mesh for 3D finite-element simulation of the alveolar structure of the pulmonary acinus [3] and to investigate the complex functional mechanism of fuel cells [4]. Further, we introduce preliminary results on the combination of absorption and phase contrast microscopy for the visualization of high-Z nanoparticles in soft tissues, a fundamental information when designing modern drug delivery systems [5]. As an outlook we briefly discuss the new possibilities offered by high sensitivity, high resolution grating interferomtery as well as Zernike Phase contrast nanotomography [6].

  11. Comparison of Different Contrast Agents in Detecting Cardiac Right-to-Left Shunt in Patients with a Patent Foramen Ovale during Contrast-Transthoracic Echocardiography

    PubMed Central

    Zhao, Enfa; Cheng, Gesheng; Wang, Yingli

    2017-01-01

    The aim of this study is to evaluate the ability of two different contrast agents to detect cardiac right-to-left shunting in patients with a patent foramen ovale during contrast transthoracic echocardiography and transesophageal echocardiography. Eighty-four patients who had migraines or experienced cryptogenic stroke were prospectively enrolled. Contrast echocardiography of the right portion of the heart was performed using an injection of either (i) 8 ml of agitated saline, 1 ml of blood, and 1 ml of air (ASB) or (ii) 4 ml of vitamin B6 and 6 ml of sodium bicarbonate solution (VSBS). All patients underwent contrast echocardiography with different contrast agents successively before undergoing transesophageal echocardiography. The diagnostic sensitivity of VSBS and ASB for cardiac shunting diagnosis was 94.23% and 78.85%, respectively. The diagnostic sensitivity in the VSBS group was significantly higher than that in the ASB group (χ2 = 5.283, P = 0.022). The observed semiquantitative shunt grading suggests that the positive rate in the VSBS group was higher than that in the ASB group (Z = −1.998, P = 0.046). The use of vitamin B6 and sodium bicarbonate solution as a TTE contrast agent yielded a high sensitivity compared with ASB. However, further trials with large sample size are required to confirm this finding. PMID:29333447

  12. Intraocular straylight and contrast sensitivity after contralateral wavefront-guided LASIK and wavefront-guided PRK for myopia.

    PubMed

    Barreto, Jackson; Barboni, Mirella T S; Feitosa-Santana, Claudia; Sato, João R; Bechara, Samir J; Ventura, Dora F; Alves, Milton Ruiz

    2010-08-01

    To compare intraocular straylight measurements and contrast sensitivity after wavefront-guided LASIK (WFG LASIK) in one eye and wavefront-guided photorefractive keratectomy (WFG PRK) in the fellow eye for myopia and myopic astigmatism correction. A prospective, randomized study of 22 eyes of 11 patients who underwent simultaneous WFG LASIK and WFG PRK (contralateral eye). Both groups were treated with the NIDEK Advanced Vision Excimer Laser System, and a microkeratome was used for flap creation in the WFG LASIK group. High and low contrast visual acuity, wavefront analysis, contrast sensitivity, and retinal straylight measurements were performed preoperatively and at 3, 6, and 12 months postoperatively. A third-generation straylight meter, C-Quant (Oculus Optikgeräte GmbH), was used for measuring intraocular straylight. Twelve months postoperatively, mean uncorrected distance visual acuity was -0.06 +/- 0.07 logMAR in the WFG LASIK group and -0.10 +/- 0.10 logMAR in the WFG PRK group. Mean preoperative intraocular straylight was 0.94 +/- 0.12 logs for the WFG LASIK group and 0.96 +/- 0.11 logs for the WFG PRK group. After 12 months, the mean straylight value was 1.01 +/- 0.1 log s for the WFG LASIK group and 0.97 +/- 0.12 log s for the WFG PRK group. No difference was found between techniques after 12 months (P = .306). No significant difference in photopic and mesopic contrast sensitivity between groups was noted. Intraocular straylight showed no statistically significant increase 1 year after WFG LASIK and WFG PRK. Higher order aberrations increased significantly after surgery for both groups. Nevertheless, WFG LASIK and WFG PRK yielded excellent visual acuity and contrast sensitivity performance without significant differences between techniques.

  13. Vision in a phase 3 trial of natalizumab for multiple sclerosis: relation to disability and quality of life.

    PubMed

    Chahin, Salim; Balcer, Laura J; Miller, Deborah M; Zhang, Annie; Galetta, Steven L

    2015-03-01

    Low-contrast visual acuity (LCVA), a sensitive measure of visual function in multiple sclerosis (MS), demonstrated treatment effects as a secondary outcome measure in the Phase 3 trial of natalizumab, AFFIRM. In these posttrial analyses, we studied the relation of visual function to quality of life (QOL), magnetic resonance imaging (MRI) measures, and Expanded Disability Status Scale (EDSS) scores. At baseline and at 52 and 104 weeks in AFFIRM, patients underwent binocular testing of LCVA (1.25% and 2.5% contrast) and high-contrast visual acuity (HCVA). Vision-specific QOL was assessed by the Impact of Visual Impairment Scale (IVIS), whereas the SF-36 Health Survey and Visual Analog Scale were administered as generic QOL measures and the EDSS as a measure of neurologic impairment. Among QOL measures, IVIS scores showed the most significant correlations with visual dysfunction at all time points in the trial (r= -0.25 to -0.45, P < 0.0001 for LCVA and HCVA). Higher MRI T1- and T2-lesion volumes were also associated with worse vision scores at all time points (P < 0.0001). Clinically meaningful worsening (progression) of LCVA was noted in substantial proportions of patients in AFFIRM and was prevalent even among those without EDSS progression over 2 years (21.9% with LCVA progression at 2.5% contrast; 26.2% at 1.25% contrast). HCVA worsened in only 3.7% of patients without EDSS progression. Loss of visual function, particularly as measured by LCVA, was common in AFFIRM, occurring in >20% of patients. Both LCVA and HCVA scores reflect vision-specific aspects of QOL, but LCVA provides information about disability progression not entirely captured by the EDSS. Vision represents a key dimension of outcome assessment for MS and adds valuable information on disability and QOL that can be useful to clinicians.

  14. Nonimmediate hypersensitivity reactions to iodinated contrast media.

    PubMed

    Gómez, Enrique; Ariza, Adriana; Blanca-López, Natalia; Torres, Maria J

    2013-08-01

    To provide a detailed analysis of the latest findings on the mechanisms underlying the nonimmediate reactions to iodinated contrast media and comment on the recent advances in diagnosis, focusing on the roles of the skin test, drug provocation test (DPT), and lymphocyte transformation test (LTT). Several studies have reported new findings supporting an important role for T-lymphocytes in the nonimmediate reactions to iodinated contrast media. The LTT has been used as an in-vitro tool for diagnosis, but with variable results. However, the inclusion of autologous monocyte-derived dendritic cells as professional antigen-presenting cells has improved the sensitivity of this test. Regarding in-vivo diagnosis, although skin testing has been routine, it has now been shown that its sensitivity and negative predictive value are low. Recent studies have demonstrated that the DPT is a well tolerated and useful procedure that is necessary to confirm the diagnosis of nonimmediate hypersensitivity reactions to iodinated contrast media. Nonimmediate reactions to contrast media are usually T-cell mediated. Diagnosis is based on skin testing, although its sensitivity and negative predictive value are not optimal. Consequently, drug provocation testing is often needed to confirm the diagnosis and also to seek alternative contrast media that can be tolerated.

  15. [Contrast-enhanced Ultrasound in Diagnostic Imaging of Muscle Injuries: Perfusion Imaging in the Early Arterial Phase].

    PubMed

    Hotfiel, T; Carl, H D; Swoboda, B; Engelhardt, M; Heinrich, M; Strobel, D; Wildner, D

    2016-03-01

    Ultrasound is a standard procedure widely used in the diagnostic investigation of muscle injuries and widely described in the literature. Its advantages include rapid availability, cost effectiveness and the possibility to perform a real-time dynamic examination with the highest possible spatial resolution. In the diagnostic work-up of minor lesions (muscle stiffness, muscle strain), plain ultrasound has so far been inferior to MRI. The case presented by us is an example of the possibilities offered by contrast-enhanced ultrasound (CEUS) in the imaging of muscle injuries compared with plain B-mode image ultrasound and MRI imaging of the affected region. This case report is about a high-performance football player who sustained a muscle injury. He underwent an ultrasound examination (S 2000, 9L4 Probe, Siemens, Germany), which was performed simultaneously in the conventional and contrast-enhanced mode at the level of the lesion. An intravenous bolus injection of 4.8 ml of intravascular contrast agent (SonoVue(®), Bracco, Italy) was given via a cubital intravenous line. After that, the distribution of contrast agent was visualised in the early arterial phase. In addition, a plain magnetic resonance imaging scan of both thighs was performed for reference. On conventional ultrasound, the lesion was not clearly distinguishable from neighbouring tissue, whereas contrast-enhanced ultrasound demonstrated a well delineated, circumscribed area of impaired perfusion with hypoenhancement compared with the surrounding muscles at the clinical level of the lesion in the arterial wash-in phase (0-30 sec, after intravenous administration). The MRI scan revealed an edema signal with perifascial fluid accumulation in the corresponding site. The use of intravascular contrast agent enabled the sensitive detection of a minor injury by ultrasound for the first time. An intramuscular edema seen in the MRI scan showed a functional arterial perfusion impairment on ultrasound, which was sensitively detected in the early phase. Further examinations must be performed on muscle injuries of various degrees of severity in order to validate the application of this procedure and to standardise the examination process. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Mechanisms of the dimming and brightening aftereffects

    PubMed Central

    Bosten, Jenny M.; MacLeod, Donald I. A.

    2013-01-01

    Abstract Dimming and brightening aftereffects occur after exposure to a temporal luminance sawtooth stimulus: A subsequently presented steady test field appears to become progressively dimmer or brighter, depending on the polarity of the adapting sawtooth. Although described as “dimming” and “brightening,” it is plausible that a component of the aftereffects is based on contrast changes rather than on luminance changes. We conducted two experiments to reveal any contrast component. In the first we investigated whether the aftereffects result from the same mechanism that causes a polarity-selective loss in contrast sensitivity following luminance sawtooth adaptation. We manipulated test contrast: If a component of the aftereffect results from a polarity selective loss of contrast sensitivity we would expect that the aftereffects would differ in magnitude depending on the contrast polarity of the test fields. We found no effect of test-field polarity. In the second experiment we used an adapting sawtooth with a polarity consistent in contrast but alternating in luminance in order to induce a potential equivalent aftereffect of contrast. Again, we found no evidence that the aftereffects result from contrast adaptation. In a third experiment, we used S-cone isolating stimuli to discover whether there are S-cone dimming and brightening aftereffects. We found no aftereffects. However, in a fourth experiment we replicated Krauskopf and Zaidi's (1986) finding that adaptation to S-cone sawtooth stimuli affects thresholds for increment and decrement detection. The mechanism underlying the dimming and brightening aftereffects thus seems to be independent of the mechanism underlying the concurrent polarity selective reductions in contrast sensitivity. PMID:23695534

  17. Fragrant Dioxane Derivatives Identify β1-Subunit-containing GABAA Receptors*

    PubMed Central

    Sergeeva, Olga A.; Kletke, Olaf; Kragler, Andrea; Poppek, Anja; Fleischer, Wiebke; Schubring, Stephan R.; Görg, Boris; Haas, Helmut L.; Zhu, Xin-Ran; Lübbert, Hermann; Gisselmann, Günter; Hatt, Hanns

    2010-01-01

    Nineteen GABAA receptor (GABAAR) subunits are known in mammals with only a restricted number of functionally identified native combinations. The physiological role of β1-subunit-containing GABAARs is unknown. Here we report the discovery of a new structural class of GABAAR positive modulators with unique β1-subunit selectivity: fragrant dioxane derivatives (FDD). At heterologously expressed α1βxγ2L (x-for 1,2,3) GABAAR FDD were 6 times more potent at β1- versus β2- and β3-containing receptors. Serine at position 265 was essential for the high sensitivity of the β1-subunit to FDD and the β1N286W mutation nearly abolished modulation; vice versa the mutation β3N265S shifted FDD sensitivity toward the β1-type. In posterior hypothalamic neurons controlling wakefulness GABA-mediated whole-cell responses and GABAergic synaptic currents were highly sensitive to FDD, in contrast to β1-negative cerebellar Purkinje neurons. Immunostaining for the β1-subunit and the potency of FDD to modulate GABA responses in cultured hypothalamic neurons was drastically diminished by β1-siRNA treatment. In conclusion, with the help of FDDs we reveal a functional expression of β1-containing GABAARs in the hypothalamus, offering a new tool for studies on the functional diversity of native GABAARs. PMID:20511229

  18. Fragrant dioxane derivatives identify beta1-subunit-containing GABAA receptors.

    PubMed

    Sergeeva, Olga A; Kletke, Olaf; Kragler, Andrea; Poppek, Anja; Fleischer, Wiebke; Schubring, Stephan R; Görg, Boris; Haas, Helmut L; Zhu, Xin-Ran; Lübbert, Hermann; Gisselmann, Günter; Hatt, Hanns

    2010-07-30

    Nineteen GABA(A) receptor (GABA(A)R) subunits are known in mammals with only a restricted number of functionally identified native combinations. The physiological role of beta1-subunit-containing GABA(A)Rs is unknown. Here we report the discovery of a new structural class of GABA(A)R positive modulators with unique beta1-subunit selectivity: fragrant dioxane derivatives (FDD). At heterologously expressed alpha1betaxgamma2L (x-for 1,2,3) GABA(A)R FDD were 6 times more potent at beta1- versus beta2- and beta3-containing receptors. Serine at position 265 was essential for the high sensitivity of the beta1-subunit to FDD and the beta1N286W mutation nearly abolished modulation; vice versa the mutation beta3N265S shifted FDD sensitivity toward the beta1-type. In posterior hypothalamic neurons controlling wakefulness GABA-mediated whole-cell responses and GABAergic synaptic currents were highly sensitive to FDD, in contrast to beta1-negative cerebellar Purkinje neurons. Immunostaining for the beta1-subunit and the potency of FDD to modulate GABA responses in cultured hypothalamic neurons was drastically diminished by beta1-siRNA treatment. In conclusion, with the help of FDDs we reveal a functional expression of beta1-containing GABA(A)Rs in the hypothalamus, offering a new tool for studies on the functional diversity of native GABA(A)Rs.

  19. Finger and foot tapping as alternative outcomes of upper and lower extremity function in multiple sclerosis.

    PubMed

    Tanigawa, Makoto; Stein, Jason; Park, John; Kosa, Peter; Cortese, Irene; Bielekova, Bibiana

    2017-01-01

    While magnetic resonance imaging contrast-enhancing lesions represent an excellent screening tool for disease-modifying treatments in relapsing-remitting multiple sclerosis (RRMS), this biomarker is insensitive for testing therapies against compartmentalized inflammation in progressive multiple sclerosis (MS). Therefore, alternative sensitive outcomes are needed. Using machine learning, clinician-acquired disability scales can be combined with timed measures of neurological functions such as walking speed (e.g. 25-foot walk; 25FW) or fine finger movements (e.g. 9-hole peg test; 9HPT) into sensitive composite clinical scales, such as the recently developed combinatorial, weight-adjusted disability scale (CombiWISE). Ideally, these complementary simplified measurements of certain neurological functions could be performed regularly at patients' homes using smartphones. We asked whether tests amenable to adaptation to smartphone technology, such as finger and foot tapping have comparable sensitivity and specificity to current non-clinician-acquired disability measures. We observed that finger and foot tapping can differentiate RRMS and progressive MS in a cross-sectional study and can also measure yearly and two-year disease progression in the latter, with better power (based on z-scores) in comparison to currently utilized 9HPT and 25FW. Replacing the 9HPT and 25FW with simplified tests broadly adaptable to smartphone technology may enhance the power of composite scales for progressive MS.

  20. Improving the depth sensitivity of time-resolved measurements by extracting the distribution of times-of-flight

    PubMed Central

    Diop, Mamadou; St. Lawrence, Keith

    2013-01-01

    Time-resolved (TR) techniques provide a means of discriminating photons based on their time-of-flight. Since early arriving photons have a lower probability of probing deeper tissue than photons with long time-of-flight, time-windowing has been suggested as a method for improving depth sensitivity. However, TR measurements also contain instrument contributions (instrument-response-function, IRF), which cause temporal broadening of the measured temporal point-spread function (TPSF) compared to the true distribution of times-of-flight (DTOF). The purpose of this study was to investigate the influence of the IRF on the depth sensitivity of TR measurements. TPSFs were acquired on homogeneous and two-layer tissue-mimicking phantoms with varying optical properties. The measured IRF and TPSFs were deconvolved using a stable algorithm to recover the DTOFs. The microscopic Beer-Lambert law was applied to the TPSFs and DTOFs to obtain depth-resolved absorption changes. In contrast to the DTOF, the latest part of the TPSF was not the most sensitive to absorption changes in the lower layer, which was confirmed by computer simulations. The improved depth sensitivity of the DTOF was illustrated in a pig model of the adult human head. Specifically, it was shown that dynamic absorption changes obtained from the late part of the DTOFs recovered from TPSFs acquired by probes positioned on the scalp were similar to absorption changes measured directly on the brain. These results collectively demonstrate that this method improves the depth sensitivity of TR measurements by removing the effects of the IRF. PMID:23504445

  1. TrkB signalling pathway mediates the protective effects of exercise in the diabetic rat retina.

    PubMed

    Allen, Rachael S; Hanif, Adam M; Gogniat, Marissa A; Prall, Brian C; Haider, Raza; Aung, Moe H; Prunty, Megan C; Mees, Lukas M; Coulter, Monica M; Motz, Cara T; Boatright, Jeffrey H; Pardue, Machelle T

    2018-05-01

    Diabetic retinopathy is a leading cause of vision loss. Treatment options for early retinopathy are sparse. Exercise protects dying photoreceptors in models of retinal degeneration, thereby preserving vision. We tested the protective effects of exercise on retinal and cognitive deficits in a type 1 diabetes model and determined whether the TrkB pathway mediates this effect. Hyperglycaemia was induced in Long Evans rats via streptozotocin injection (STZ; 100 mg/kg). Following confirmed hyperglycaemia, both control and diabetic rats underwent treadmill exercise for 30 min, 5 days/week at 0 m/min (inactive groups) or 15 m/min (active groups) for 8 weeks. A TrkB receptor antagonist (ANA-12), or vehicle, was injected 2.5 h before exercise training. We measured spatial frequency and contrast sensitivity using optokinetic tracking biweekly post-STZ; retinal function using electroretinography at 4 and 8 weeks; and cognitive function and exploratory behaviour using Y-maze at 8 weeks. Retinal neurotrophin-4 was measured using ELISA. Compared with non-diabetic controls, diabetic rats showed significantly reduced spatial frequency and contrast sensitivity, delayed electroretinogram oscillatory potential and flicker implicit times and reduced cognitive function and exploratory behaviour. Exercise interventions significantly delayed the appearance of all deficits, except for exploratory behaviour. Treatment with ANA-12 significantly reduced this protection, suggesting a TrkB-mediated mechanism. Despite this, no changes in retinal neurotrohin-4 were observed with diabetes or exercise. Exercise protected against early visual and cognitive dysfunction in diabetic rats, suggesting that exercise interventions started after hyperglycaemia diagnosis may be a beneficial treatment. The translational potential is high, given that exercise treatment is non-invasive, patient controlled and inexpensive. © 2018 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  2. Impact of cataract surgery on vision-related life performances: the usefulness of Real-Life Vision Test for cataract surgery outcomes evaluation

    PubMed Central

    Ni, W; Li, X; Hou, Z; Zhang, H; Qiu, W; Wang, W

    2015-01-01

    Purpose Real-Life Vision Test (RLVT) is a newly developed performance-based measures of functional vision. This present study is designed to determine whether it could be a meaningful assessment for cataract surgery outcomes evaluation. Patients and methods Age-related cataract patients (56) who scheduled for bilateral cataract surgery and 44 age-matched controls were evaluated by four types of measurements: (1) demographic, medical, cognitive and depressive evaluation, and the reaction time testing; (2) clinical measures (visual acuity, contrast sensitivity, stereopsis, and color perception); (3) the 25-item National Eye Institute's Visual Functioning Questionnaire (NEI-VFQ); (4) the RLVT. Spearman's coefficients and multiple regression analysis were conducted to investigate the relationship among RLVT, clinical measures, and self-report assessment of visual function. Results The results of RLVT, clinical measures, and NEI-VFQ total scores were improved significantly after cataract surgery. There were no differences between control subjects and post-surgery patients with respect to NEI-VFQ-25 total scores, self-rating depression scale scores and three tasks of RLVT. Change of RLVT was significantly associated with the change of clinical measures in the cataract group. Multiple regression analysis demonstrated that change of distance, intermediate, and near visual acuity, and binocular contrast sensitivity were significant predictors of improvements of RLVT. Conclusions Cataract surgery could improve real-world visual ability effectively for cataract patients. Our study highlights the potential usefulness of RLVT as an adjunct to the current outcomes evaluation system for cataract surgery. The use of RLVT combined with clinical and self-survey methods may be the comprehensive strategy to manifest the impact of cataract surgery on patients' overall vision-related quality of life. PMID:26272444

  3. Functional Diversity of Human Mitochondrial J-proteins Is Independent of Their Association with the Inner Membrane Presequence Translocase.

    PubMed

    Sinha, Devanjan; Srivastava, Shubhi; D'Silva, Patrick

    2016-08-12

    Mitochondrial J-proteins play a critical role in governing Hsp70 activity and, hence, are essential for organellar protein translocation and folding. In contrast to yeast, which has a single J-protein Pam18, humans involve two J-proteins, DnaJC15 and DnaJC19, associated with contrasting cellular phenotype, to transport proteins into the mitochondria. Mutation in DnaJC19 results in dilated cardiomyopathy and ataxia syndrome, whereas expression of DnaJC15 regulates the response of cancer cells to chemotherapy. In the present study we have comparatively assessed the biochemical properties of the J-protein paralogs in relation to their association with the import channel. Both DnaJC15 and DnaJC19 formed two distinct subcomplexes with Magmas at the import channel. Knockdown analysis suggested an essential role for Magmas and DnaJC19 in organellar protein translocation and mitochondria biogenesis, whereas DnaJC15 had dispensable supportive function. The J-proteins were found to have equal affinity for Magmas and could stimulate mitochondrial Hsp70 ATPase activity by equivalent levels. Interestingly, we observed that DnaJC15 exhibits bifunctional properties. At the translocation channel, it involves conserved interactions and mechanism to translocate the precursors into mitochondria. In addition to protein transport, DnaJC15 also showed a dual role in yeast where its expression elicited enhanced sensitivity of cells to cisplatin that required the presence of a functional J-domain. The amount of DnaJC15 expressed in the cell was directly proportional to the sensitivity of cells. Our analysis indicates that the differential cellular phenotype displayed by human mitochondrial J-proteins is independent of their activity and association with Magmas at the translocation channel. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.

  4. Functional and morphological assessment of ocular structures and follow-up of patients with early-stage Parkinson's disease.

    PubMed

    Hasanov, Samir; Demirkilinc Biler, Elif; Acarer, Ahmet; Akkın, Cezmi; Colakoglu, Zafer; Uretmen, Onder

    2018-05-09

    To evaluate and follow-up of functional and morphological changes of the optic nerve and ocular structures prospectively in patients with early-stage Parkinson's disease. Nineteen patients with a diagnosis of early-stage Parkinson's disease and 19 age-matched healthy controls were included in the study. All participants were examined minimum three times at the intervals of at least 6 month following initial examination. Pattern visually evoked potentials (VEP), contrast sensitivity assessments at photopic conditions, color vision tests with Ishihara cards and full-field visual field tests were performed in addition to measurement of retinal nerve fiber layer (RNFL) thickness of four quadrants (top, bottom, nasal, temporal), central and mean macular thickness and macular volumes. Best corrected visual acuity was observed significantly lower in study group within all three examinations. Contrast sensitivity values of the patient group were significantly lower in all spatial frequencies. P100 wave latency of VEP was significantly longer, and amplitude was lower in patient group; however, significant deterioration was not observed during the follow-up. Although average peripapillary RNFL thickness was not significant between groups, RNFL thickness in the upper quadrant was thinner in the patient group. While there was no difference in terms of mean macular thickness and total macular volume values between the groups initially, a significant decrease occurred in the patient group during the follow-up. During the initial and follow-up process, a significant deterioration in visual field was observed in the patient group. Structural and functional disorders shown as electro-physiologically and morphologically exist in different parts of visual pathways in early-stage Parkinson's disease.

  5. Experiments in Reconstructing Twentieth-Century Sea Levels

    NASA Technical Reports Server (NTRS)

    Ray, Richard D.; Douglas, Bruce C.

    2011-01-01

    One approach to reconstructing historical sea level from the relatively sparse tide-gauge network is to employ Empirical Orthogonal Functions (EOFs) as interpolatory spatial basis functions. The EOFs are determined from independent global data, generally sea-surface heights from either satellite altimetry or a numerical ocean model. The problem is revisited here for sea level since 1900. A new approach to handling the tide-gauge datum problem by direct solution offers possible advantages over the method of integrating sea-level differences, with the potential of eventually adjusting datums into the global terrestrial reference frame. The resulting time series of global mean sea levels appears fairly insensitive to the adopted set of EOFs. In contrast, charts of regional sea level anomalies and trends are very sensitive to the adopted set of EOFs, especially for the sparser network of gauges in the early 20th century. The reconstructions appear especially suspect before 1950 in the tropical Pacific. While this limits some applications of the sea-level reconstructions, the sensitivity does appear adequately captured by formal uncertainties. All our solutions show regional trends over the past five decades to be fairly uniform throughout the global ocean, in contrast to trends observed over the shorter altimeter era. Consistent with several previous estimates, the global sea-level rise since 1900 is 1.70 +/- 0.26 mm/yr. The global trend since 1995 exceeds 3 mm/yr which is consistent with altimeter measurements, but this large trend was possibly also reached between 1935 and 1950.

  6. Visual defects in a mouse model of fetal alcohol spectrum disorder.

    PubMed

    Lantz, Crystal L; Pulimood, Nisha S; Rodrigues-Junior, Wandilson S; Chen, Ching-Kang; Manhaes, Alex C; Kalatsky, Valery A; Medina, Alexandre Esteves

    2014-01-01

    Alcohol consumption during pregnancy can lead to a multitude of neurological problems in offspring, varying from subtle behavioral changes to severe mental retardation. These alterations are collectively referred to as Fetal Alcohol Spectrum Disorders (FASD). Early alcohol exposure can strongly affect the visual system and children with FASD can exhibit an amblyopia-like pattern of visual acuity deficits even in the absence of optical and oculomotor disruption. Here, we test whether early alcohol exposure can lead to a disruption in visual acuity, using a model of FASD to mimic alcohol consumption in the last months of human gestation. To accomplish this, mice were exposed to ethanol (5 g/kg i.p.) or saline on postnatal days (P) 5, 7, and 9. Two to three weeks later we recorded visually evoked potentials to assess spatial frequency detection and contrast sensitivity, conducted electroretinography (ERG) to further assess visual function and imaged retinotopy using optical imaging of intrinsic signals. We observed that animals exposed to ethanol displayed spatial frequency acuity curves similar to controls. However, ethanol-treated animals showed a significant deficit in contrast sensitivity. Moreover, ERGs revealed a market decrease in both a- and b-waves amplitudes, and optical imaging suggest that both elevation and azimuth maps in ethanol-treated animals have a 10-20° greater map tilt compared to saline-treated controls. Overall, our findings suggest that binge alcohol drinking restricted to the last months of gestation in humans can lead to marked deficits in visual function.

  7. Cold shock domain proteins and glycine-rich RNA-binding proteins from Arabidopsis thaliana can promote the cold adaptation process in Escherichia coli

    PubMed Central

    Kim, Jin Sun; Park, Su Jung; Kwak, Kyung Jin; Kim, Yeon Ok; Kim, Joo Yeol; Song, Jinkyung; Jang, Boseung; Jung, Che-Hun; Kang, Hunseung

    2007-01-01

    Despite the fact that cold shock domain proteins (CSDPs) and glycine-rich RNA-binding proteins (GRPs) have been implicated to play a role during the cold adaptation process, their importance and function in eukaryotes, including plants, are largely unknown. To understand the functional role of plant CSDPs and GRPs in the cold response, two CSDPs (CSDP1 and CSDP2) and three GRPs (GRP2, GRP4 and GRP7) from Arabidopsis thaliana were investigated. Heterologous expression of CSDP1 or GRP7 complemented the cold sensitivity of BX04 mutant Escherichia coli that lack four cold shock proteins (CSPs) and is highly sensitive to cold stress, and resulted in better survival rate than control cells during incubation at low temperature. In contrast, CSDP2 and GRP4 had very little ability. Selective evolution of ligand by exponential enrichment (SELEX) revealed that GRP7 does not recognize specific RNAs but binds preferentially to G-rich RNA sequences. CSDP1 and GRP7 had DNA melting activity, and enhanced RNase activity. In contrast, CSDP2 and GRP4 had no DNA melting activity and did not enhance RNAase activity. Together, these results indicate that CSDPs and GRPs help E.coli grow and survive better during cold shock, and strongly imply that CSDP1 and GRP7 exhibit RNA chaperone activity during the cold adaptation process. PMID:17169986

  8. Comparative sensitivities of functional MRI sequences in detection of local recurrence of prostate carcinoma after radical prostatectomy or external-beam radiotherapy.

    PubMed

    Roy, Catherine; Foudi, Fatah; Charton, Jeanne; Jung, Michel; Lang, Hervé; Saussine, Christian; Jacqmin, Didier

    2013-04-01

    The aim of this retrospective study was to determine the respective accuracies of three types of functional MRI sequences-diffusion-weighted imaging (DWI), dynamic contrast-enhanced (DCE) MRI, and 3D (1)H-MR spectroscopy (MRS)-in the depiction of local prostate cancer recurrence after two different initial therapy options. From a cohort of 83 patients with suspicion of local recurrence based on prostate-specific antigen (PSA) kinetics who were imaged on a 3-T MRI unit using an identical protocol including the three functional sequences with an endorectal coil, we selected 60 patients (group A, 28 patients who underwent radical prostatectomy; group B, 32 patients who underwent external-beam radiation) who had local recurrence ascertained on the basis of a transrectal ultrasound-guided biopsy results and a reduction in PSA level after salvage therapy. All patients presented with a local relapse. Sensitivity with T2-weighted MRI and 3D (1)H-MRS sequences was 57% and 53%, respectively, for group A and 71% and 78%, respectively, for group B. DCE-MRI alone showed a sensitivity of 100% and 96%, respectively, for groups A and B. DWI alone had a higher sensitivity for group B (96%) than for group A (71%). The combination of T2-weighted imaging plus DWI plus DCE-MRI provided a sensitivity as high as 100% in group B. The performance of functional imaging sequences for detecting recurrence is different after radical prostatectomy and external-beam radiotherapy. DCE-MRI is a valid and efficient tool to detect prostate cancer recurrence in radical prostatectomy as well as in external-beam radiotherapy. The combination of DCE-MRI and DWI is highly efficient after radiation therapy. Three-dimensional (1)H-MRS needs to be improved. Even though it is not accurate enough, T2-weighted imaging remains essential for the morphologic analysis of the area.

  9. Perceptual Improvement of Lexical Tones in Infants: Effects of Tone Language Experience

    PubMed Central

    Tsao, Feng-Ming

    2017-01-01

    To learn words in a tonal language, tone-language learners should not only develop better abilities for perceiving consonants and vowels, but also for lexical tones. The divergent trend of enhancing sensitivity to native phonetic contrasts and reduced sensitivity to non-native phonetic contrast is theoretically essential to evaluate effects of listening to an ambient language on speech perception development. The loss of sensitivity in discriminating lexical tones among non-tonal language-learning infants was apparent between 6 and 12 months of age, but only few studies examined trends of differentiating native lexical tones in infancy. The sensitivity in discriminating lexical tones among 6–8 and 10–12 month-old Mandarin-learning infants (n = 120) was tested in Experiment 1 using three lexical tone contrasts of Mandarin. Facilitation of linguistic experience was shown in the tonal contrast (Tone 1 vs. 3), but both age groups performed similar in the other two tonal contrasts (Tone 2 vs. 4; Tone 2 vs. 3). In Experiment 2, 6–8 and 10–12 month-old Mandarin-learning infants (n = 90) were tested with tonal contrasts that have pitch contours either similar to or inverse from lexical tones in Mandarin, and perceptual improvement was shown only in a tonal contrast with familiar pitch contours (i.e., Tone 1 vs. 3). In Experiment 3, 6–8 and 10–12 month-old English-learning infants (n = 40) were tested with Tone 1 vs. 3 contrast of Mandarin and showed an improvement in the perception of non-native lexical tones. This study reveals that tone-language learning infants develop more accurate representations of lexical tones around their first birthday, and the results of both tone and non-tone language-learning infants imply that the rate of development depends on listening experience and the acoustical salience of specific tone contrasts. PMID:28443053

  10. Functional connectivity density mapping: comparing multiband and conventional EPI protocols.

    PubMed

    Cohen, Alexander D; Tomasi, Dardo; Shokri-Kojori, Ehsan; Nencka, Andrew S; Wang, Yang

    2018-06-01

    Functional connectivity density mapping (FCDM) is a newly developed data-driven technique that quantifies the number of local and global functional connections for each voxel in the brain. In this study, we evaluated reproducibility, sensitivity, and specificity of both local functional connectivity density (lFCD) and global functional connectivity density (gFCD). We compared these metrics using the human connectome project (HCP) compatible high-resolution (2 mm isotropic, TR = 0.8 s) multiband (MB), and more typical, lower resolution (3.5 mm isotropic, TR = 2.0 s) single-band (SB) resting state functional MRI (rs-fMRI) acquisitions. Furthermore, in order to be more clinically feasible, only rs-fMRI scans that lasted seven minutes were tested. Subjects were scanned twice within a two-week span. We found sensitivity and specificity increased and reproducibility either increased or did not change for the MB compared to the SB acquisitions. The MB scans also showed improved gray matter/white matter contrast compared to the SB scans. The lFCD and gFCD patterns were similar across MB and SB scans and confined predominantly to gray matter. We also observed a strong spatial correlation of FCD between MB and SB scans indicating the two acquisitions provide similar information. These findings indicate high-resolution MB acquisitions improve the quality of FCD data, and seven minute rs-fMRI scan can provide robust FCD measurements.

  11. Brain regions sensitive to the face inversion effect: a functional magnetic resonance imaging study in humans.

    PubMed

    Leube, Dirk T; Yoon, Hyo Woon; Rapp, Alexander; Erb, Michael; Grodd, Wolfgang; Bartels, Mathias; Kircher, Tilo T J

    2003-05-22

    Perception of upright faces relies on configural processing. Therefore recognition of inverted, compared to upright faces is impaired. In a functional magnetic resonance imaging experiment we investigated the neural correlate of a face inversion task. Thirteen healthy subjects were presented with a equal number of upright and inverted faces alternating with a low level baseline with an upright and inverted picture of an abstract symbol. Brain activation was calculated for upright minus inverted faces. For this differential contrast, we found a signal change in the right superior temporal sulcus and right insula. Configural properties are processed in a network comprising right superior temporal and insular cortex.

  12. Changes in Visual Function Following Optical Treatment of Astigmatism-Related Amblyopia

    PubMed Central

    Harvey, Erin M.; Dobson, Velma; Miller, Joseph M.; Donaldson, Candice E.

    2009-01-01

    Effects of optical correction on best-corrected grating acuity (vertical (V), horizontal (H), oblique (O)), vernier acuity (V, H, O), contrast sensitivity (1.5, 6.0, and 18.0 cy/deg spatial frequency, V and H), and stereoacuity were evaluated prospectively in 4- to 13-year-old astigmats and a non-astigmatic age-matched control group. Measurements made at baseline (eyeglasses dispensed for astigmats), 6 weeks, and 1 year showed greater improvement in astigmatic than non-astigmatic children for all measures. Treatment effects occurred by 6 weeks, and did not differ by cohort (< 8 vs. 8 years), but astigmatic children did not attain normal levels of visual function. PMID:18261760

  13. Night vision in barn owls: visual acuity and contrast sensitivity under dark adaptation.

    PubMed

    Orlowski, Julius; Harmening, Wolf; Wagner, Hermann

    2012-12-06

    Barn owls are effective nocturnal predators. We tested their visual performance at low light levels and determined visual acuity and contrast sensitivity of three barn owls by their behavior at stimulus luminances ranging from photopic to fully scotopic levels (23.5 to 1.5 × 10⁻⁶). Contrast sensitivity and visual acuity decreased only slightly from photopic to scotopic conditions. Peak grating acuity was at mesopic (4 × 10⁻² cd/m²) conditions. Barn owls retained a quarter of their maximal acuity when luminance decreased by 5.5 log units. We argue that the visual system of barn owls is designed to yield as much visual acuity under low light conditions as possible, thereby sacrificing resolution at photopic conditions.

  14. Effect of inherent location uncertainty on detection of stationary targets in noisy image sequences.

    PubMed

    Manjeshwar, R M; Wilson, D L

    2001-01-01

    The effect of inherent location uncertainty on the detection of stationary targets was determined in noisy image sequences. Targets were thick and thin projected cylinders mimicking arteries, catheters, and guide wires in medical imaging x-ray fluoroscopy. With the use of an adaptive forced-choice method, detection contrast sensitivity (the inverse of contrast) was measured both with and without marker cues that directed the attention of observers to the target location. With the probability correct clamped at 80%, contrast sensitivity increased an average of 77% when the marker was added to the thin-cylinder target. There was an insignificant effect on the thick cylinder. The large enhancement with the thin cylinder was obtained even though the target was located exactly in the center of a small panel, giving observers the impression that it was well localized. Psychometric functions consisting of d' plotted as a function of the square root of the signal-energy-to-noise-ratio gave a positive x intercept for the case of the thin cylinder without a marker. This x intercept, characteristic of uncertainty in other types of detection experiments, disappeared when the marker was added or when the thick cylinder was used. Inherent location uncertainty was further characterized by using four different markers with varying proximity to the target. Visual detection by human observers increased monotonically as the markers better localized the target. Human performance was modeled as a matched-filter detector with an uncertainty in the placement of the template. The removal of a location cue was modeled by introducing a location uncertainty of approximately equals 0.4 mm on the display device or only 7 microm on the retina, a size on the order of a single photoreceptor field. We conclude that detection is affected by target location uncertainty on the order of cellular dimensions, an observation with important implications for detection mechanisms in humans. In medical imaging, the results argue strongly for inclusion of high-contrast visualization markers on catheters and other interventional devices.

  15. Assessment of the reliability of standard automated perimetry in regions of glaucomatous damage.

    PubMed

    Gardiner, Stuart K; Swanson, William H; Goren, Deborah; Mansberger, Steven L; Demirel, Shaban

    2014-07-01

    Visual field testing uses high-contrast stimuli in areas of severe visual field loss. However, retinal ganglion cells saturate with high-contrast stimuli, suggesting that the probability of detecting perimetric stimuli may not increase indefinitely as contrast increases. Driven by this concept, this study examines the lower limit of perimetric sensitivity for reliable testing by standard automated perimetry. Evaluation of a diagnostic test. A total of 34 participants with moderate to severe glaucoma; mean deviation at their last clinic visit averaged -10.90 dB (range, -20.94 to -3.38 dB). A total of 75 of the 136 locations tested had a perimetric sensitivity of ≤ 19 dB. Frequency-of-seeing curves were constructed at 4 nonadjacent visual field locations by the Method of Constant Stimuli (MOCS), using 35 stimulus presentations at each of 7 contrasts. Locations were chosen a priori and included at least 2 with glaucomatous damage but a sensitivity of ≥ 6 dB. Cumulative Gaussian curves were fit to the data, first assuming a 5% false-negative rate and subsequently allowing the asymptotic maximum response probability to be a free parameter. The strength of the relation (R(2)) between perimetric sensitivity (mean of last 2 clinic visits) and MOCS sensitivity (from the experiment) for all locations with perimetric sensitivity within ± 4 dB of each selected value, at 0.5 dB intervals. Bins centered at sensitivities ≥ 19 dB always had R(2) >0.1. All bins centered at sensitivities ≤ 15 dB had R(2) <0.1, an indication that sensitivities are unreliable. No consistent conclusions could be drawn between 15 and 19 dB. At 57 of the 81 locations with perimetric sensitivity <19 dB, including 49 of the 63 locations ≤ 15 dB, the fitted asymptotic maximum response probability was <80%, consistent with the hypothesis of response saturation. At 29 of these locations the asymptotic maximum was <50%, and so contrast sensitivity (50% response rate) is undefined. Clinical visual field testing may be unreliable when visual field locations have sensitivity below approximately 15 to 19 dB because of a reduction in the asymptotic maximum response probability. Researchers and clinicians may have difficulty detecting worsening sensitivity in these visual field locations, and this difficulty may occur commonly in patients with glaucoma with moderate to severe glaucomatous visual field loss. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  16. Altered sensitization patterns to sweet food stimuli in patients recovered from anorexia and bulimia nervosa.

    PubMed

    Wagner, Angela; Simmons, Alan N; Oberndorfer, Tyson A; Frank, Guido K W; McCurdy-McKinnon, Danyale; Fudge, Julie L; Yang, Tony T; Paulus, Martin P; Kaye, Walter H

    2015-12-30

    Recent studies show that higher-order appetitive neural circuitry may contribute to restricted eating in anorexia nervosa (AN) and overeating in bulimia nervosa (BN). The purpose of this study was to determine whether sensitization effects might underlie pathologic eating behavior when a taste stimulus is administered repeatedly. Recovered AN (RAN, n=14) and BN (RBN, n=15) subjects were studied in order to avoid the confounding effects of altered nutritional state. Functional magnetic resonance imaging (fMRI) measured higher-order brain response to repeated tastes of sucrose (caloric) and sucralose (non-caloric). To test sensitization, the neuronal response to the first and second administration was compared. RAN patients demonstrated a decreased sensitization to sucrose in contrast to RBN patients who displayed the opposite pattern, increased sensitization to sucrose. However, the latter was not as pronounced as in healthy control women (n=13). While both eating disorder subgroups showed increased sensitization to sucralose, the healthy controls revealed decreased sensitization. These findings could reflect on a neuronal level the high caloric intake of RBN during binges and the low energy intake for RAN. RAN seem to distinguish between high energy and low energy sweet stimuli while RBN do not. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  17. High sensitivity phase retrieval method in grating-based x-ray phase contrast imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Zhao; Gao, Kun; Chen, Jian

    2015-02-15

    Purpose: Grating-based x-ray phase contrast imaging is considered as one of the most promising techniques for future medical imaging. Many different methods have been developed to retrieve phase signal, among which the phase stepping (PS) method is widely used. However, further practical implementations are hindered, due to its complex scanning mode and high radiation dose. In contrast, the reverse projection (RP) method is a novel fast and low dose extraction approach. In this contribution, the authors present a quantitative analysis of the noise properties of the refraction signals retrieved by the two methods and compare their sensitivities. Methods: Using themore » error propagation formula, the authors analyze theoretically the signal-to-noise ratios (SNRs) of the refraction images retrieved by the two methods. Then, the sensitivities of the two extraction methods are compared under an identical exposure dose. Numerical experiments are performed to validate the theoretical results and provide some quantitative insight. Results: The SNRs of the two methods are both dependent on the system parameters, but in different ways. Comparison between their sensitivities reveals that for the refraction signal, the RP method possesses a higher sensitivity, especially in the case of high visibility and/or at the edge of the object. Conclusions: Compared with the PS method, the RP method has a superior sensitivity and provides refraction images with a higher SNR. Therefore, one can obtain highly sensitive refraction images in grating-based phase contrast imaging. This is very important for future preclinical and clinical implementations.« less

  18. Assessment of Age-Related Differences in Functional Capacity Using the Virtual Reality Functional Capacity Assessment Tool (VRFCAT)

    PubMed Central

    Atkins, A.S.; Stroescu, I.; Spagnola, N.B.; Davis, V.G.; Patterson, T.D.; Narasimhan, M.; Harvey, P.D.; Keefe, R.S.E.

    2015-01-01

    Clinical trials for primary prevention and early intervention in preclinical AD require measures of functional capacity with improved sensitivity to deficits in healthier, non-demented individuals. To this end, the Virtual Reality Functional Capacity Assessment Tool (VRFCAT) was developed as a direct performance-based assessment of functional capacity that is sensitive to changes in function across multiple populations. Using a realistic virtual reality environment, the VRFCAT assesses a subject's ability to complete instrumental activities associated with a shopping trip. The present investigation represents an initial evaluation of the VRFCAT as a potential co-primary measure of functional capacity in healthy aging and preclinical MCI/AD by examining test-retest reliability and associations with cognitive performance in healthy young and older adults. The VRFCAT was compared and contrasted with the UPSA-2-VIM, a traditional performance-based assessment utilizing physical props. Results demonstrated strong age-related differences in performance on each VRFCAT outcome measure, including total completion time, total errors, and total forced progressions. VRFCAT performance showed strong correlations with cognitive performance across both age groups. VRFCAT Total Time demonstrated good test-retest reliability (ICC=.80 in young adults; ICC=.64 in older adults) and insignificant practice effects, indicating the measure is suitable for repeated testing in healthy populations. Taken together, these results provide preliminary support for the VRFCAT as a potential measure of functionally relevant change in primary prevention and preclinical AD/MCI trials. PMID:26618145

  19. Planar implantable sensor for in vivo measurement of cellular oxygen metabolism in brain tissue.

    PubMed

    Tsytsarev, Vassiliy; Akkentli, Fatih; Pumbo, Elena; Tang, Qinggong; Chen, Yu; Erzurumlu, Reha S; Papkovsky, Dmitri B

    2017-04-01

    Brain imaging methods are continually improving. Imaging of the cerebral cortex is widely used in both animal experiments and charting human brain function in health and disease. Among the animal models, the rodent cerebral cortex has been widely used because of patterned neural representation of the whiskers on the snout and relative ease of activating cortical tissue with whisker stimulation. We tested a new planar solid-state oxygen sensor comprising a polymeric film with a phosphorescent oxygen-sensitive coating on the working side, to monitor dynamics of oxygen metabolism in the cerebral cortex following sensory stimulation. Sensory stimulation led to changes in oxygenation and deoxygenation processes of activated areas in the barrel cortex. We demonstrate the possibility of dynamic mapping of relative changes in oxygenation in live mouse brain tissue with such a sensor. Oxygenation-based functional magnetic resonance imaging (fMRI) is very effective method for functional brain mapping but have high costs and limited spatial resolution. Optical imaging of intrinsic signal (IOS) does not provide the required sensitivity, and voltage-sensitive dye optical imaging (VSDi) has limited applicability due to significant toxicity of the voltage-sensitive dye. Our planar solid-state oxygen sensor imaging approach circumvents these limitations, providing a simple optical contrast agent with low toxicity and rapid application. The planar solid-state oxygen sensor described here can be used as a tool in visualization and real-time analysis of sensory-evoked neural activity in vivo. Further, this approach allows visualization of local neural activity with high temporal and spatial resolution. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. The Application of MRI for Depiction of Subtle Blood Brain Barrier Disruption in Stroke

    PubMed Central

    Israeli, David; Tanne, David; Daniels, Dianne; Last, David; Shneor, Ran; Guez, David; Landau, Efrat; Roth, Yiftach; Ocherashvilli, Aharon; Bakon, Mati; Hoffman, Chen; Weinberg, Amit; Volk, Talila; Mardor, Yael

    2011-01-01

    The development of imaging methodologies for detecting blood-brain-barrier (BBB) disruption may help predict stroke patient's propensity to develop hemorrhagic complications following reperfusion. We have developed a delayed contrast extravasation MRI-based methodology enabling real-time depiction of subtle BBB abnormalities in humans with high sensitivity to BBB disruption and high spatial resolution. The increased sensitivity to subtle BBB disruption is obtained by acquiring T1-weighted MRI at relatively long delays (~15 minutes) after contrast injection and subtracting from them images acquired immediately after contrast administration. In addition, the relatively long delays allow for acquisition of high resolution images resulting in high resolution BBB disruption maps. The sensitivity is further increased by image preprocessing with corrections for intensity variations and with whole body (rigid+elastic) registration. Since only two separate time points are required, the time between the two acquisitions can be used for acquiring routine clinical data, keeping the total imaging time to a minimum. A proof of concept study was performed in 34 patients with ischemic stroke and 2 patients with brain metastases undergoing high resolution T1-weighted MRI acquired at 3 time points after contrast injection. The MR images were pre-processed and subtracted to produce BBB disruption maps. BBB maps of patients with brain metastases and ischemic stroke presented different patterns of BBB opening. The significant advantage of the long extravasation time was demonstrated by a dynamic-contrast-enhancement study performed continuously for 18 min. The high sensitivity of our methodology enabled depiction of clear BBB disruption in 27% of the stroke patients who did not have abnormalities on conventional contrast-enhanced MRI. In 36% of the patients, who had abnormalities detectable by conventional MRI, the BBB disruption volumes were significantly larger in the maps than in conventional MRI. These results demonstrate the advantages of delayed contrast extravasation in increasing the sensitivity to subtle BBB disruption in ischemic stroke patients. The calculated disruption maps provide clear depiction of significant volumes of BBB disruption unattainable by conventional contrast-enhanced MRI. PMID:21209786

  1. The application of MRI for depiction of subtle blood brain barrier disruption in stroke.

    PubMed

    Israeli, David; Tanne, David; Daniels, Dianne; Last, David; Shneor, Ran; Guez, David; Landau, Efrat; Roth, Yiftach; Ocherashvilli, Aharon; Bakon, Mati; Hoffman, Chen; Weinberg, Amit; Volk, Talila; Mardor, Yael

    2010-12-26

    The development of imaging methodologies for detecting blood-brain-barrier (BBB) disruption may help predict stroke patient's propensity to develop hemorrhagic complications following reperfusion. We have developed a delayed contrast extravasation MRI-based methodology enabling real-time depiction of subtle BBB abnormalities in humans with high sensitivity to BBB disruption and high spatial resolution. The increased sensitivity to subtle BBB disruption is obtained by acquiring T1-weighted MRI at relatively long delays (~15 minutes) after contrast injection and subtracting from them images acquired immediately after contrast administration. In addition, the relatively long delays allow for acquisition of high resolution images resulting in high resolution BBB disruption maps. The sensitivity is further increased by image preprocessing with corrections for intensity variations and with whole body (rigid+elastic) registration. Since only two separate time points are required, the time between the two acquisitions can be used for acquiring routine clinical data, keeping the total imaging time to a minimum. A proof of concept study was performed in 34 patients with ischemic stroke and 2 patients with brain metastases undergoing high resolution T1-weighted MRI acquired at 3 time points after contrast injection. The MR images were pre-processed and subtracted to produce BBB disruption maps. BBB maps of patients with brain metastases and ischemic stroke presented different patterns of BBB opening. The significant advantage of the long extravasation time was demonstrated by a dynamic-contrast-enhancement study performed continuously for 18 min. The high sensitivity of our methodology enabled depiction of clear BBB disruption in 27% of the stroke patients who did not have abnormalities on conventional contrast-enhanced MRI. In 36% of the patients, who had abnormalities detectable by conventional MRI, the BBB disruption volumes were significantly larger in the maps than in conventional MRI. These results demonstrate the advantages of delayed contrast extravasation in increasing the sensitivity to subtle BBB disruption in ischemic stroke patients. The calculated disruption maps provide clear depiction of significant volumes of BBB disruption unattainable by conventional contrast-enhanced MRI.

  2. Classification of cardiac-related artifacts in dynamic contrast breast MRI

    NASA Astrophysics Data System (ADS)

    Stegbauer, Keith C.; Smith, Justin P.; Niemeyer, Tanya L.; Wood, Chris

    2004-05-01

    Dynamic contrast breast MRI is becoming an important adjunct in screening women at high risk for breast cancer, determining extent of disease (staging) and monitoring response to therapy. In dynamic contrast breast MRI, regions of rapid contrast uptake indicate increases in vascularity which can be associated with abnormal tissue, sometimes significant for malignant disease. To show these areas of enhancement, subtractions between the pre and post contrast images and maximum intensity projections (MIPs) are computed. Many projections are obscured by normally enhancing anatomy (heart, aorta, pulmonary vessels). Identification of these structures allows their removal from MIPs, which improves image quality, diagnostic utility and the conspicuity of the enhancing regions. In this study, a fully automated classifier is presented which uses the spatial location of enhancing regions to separate those that occur inside the chest wall from those occurring in the tissue of interest (breast, axilla, chest wall). The classifier was trained on 21 studies each acquired at a different institution (699 clusters of pixels), and tested on 7 studies (231 clusters of pixels) that were not part of the training set. Multiple cost functions for training were examined. The measurements for the peak performance of the classifier were sensitivity 97.0%, specificity 99.4%, PPV 99.9%, NPV 78.8%.

  3. Functional characterization of the extraclassical receptive field in macaque V1: contrast, orientation, and temporal dynamics.

    PubMed

    Henry, Christopher A; Joshi, Siddhartha; Xing, Dajun; Shapley, Robert M; Hawken, Michael J

    2013-04-03

    Neurons in primary visual cortex, V1, very often have extraclassical receptive fields (eCRFs). The eCRF is defined as the region of visual space where stimuli cannot elicit a spiking response but can modulate the response of a stimulus in the classical receptive field (CRF). We investigated the dependence of the eCRF on stimulus contrast and orientation in macaque V1 cells for which the laminar location was determined. The eCRF was more sensitive to contrast than the CRF across the whole population of V1 cells with the greatest contrast differential in layer 2/3. We confirmed that many V1 cells experience stronger suppression for collinear than orthogonal stimuli in the eCRF. Laminar analysis revealed that the predominant bias for collinear suppression was found in layers 2/3 and 4b. The laminar pattern of contrast and orientation dependence suggests that eCRF suppression may derive from different neural circuits in different layers, and may be comprised of two distinct components: orientation-tuned and untuned suppression. On average tuned suppression was delayed by ∼25 ms compared with the onset of untuned suppression. Therefore, response modulation by the eCRF develops dynamically and rapidly in time.

  4. Ultra-wide range field-dependent measurements of the relaxivity of Gd1−xEuxVO4 nanoparticle contrast agents using a mechanical sample-shuttling relaxometer

    PubMed Central

    Chou, Ching-Yu; Abdesselem, Mouna; Bouzigues, Cedric; Chu, Minglee; Guiga, Angelo; Huang, Tai-Huang; Ferrage, Fabien; Gacoin, Thierry; Alexandrou, Antigoni; Sakellariou, Dimitris

    2017-01-01

    The current trend for Magnetic Resonance Imaging points towards higher magnetic fields. Even though sensitivity and resolution are increased in stronger fields, T1 contrast is often reduced, and this represents a challenge for contrast agent design. Field-dependent measurements of relaxivity are thus important to characterize contrast agents. At present, the field-dependent curves of relaxivity are usually carried out in the field range of 0 T to 2 T, using fast field cycling relaxometers. Here, we employ a high-speed sample shuttling device to switch the magnetic fields experienced by the nuclei between virtually zero field, and the center of any commercial spectrometer. We apply this approach on rare-earth (mixed Gadolinium-Europium) vanadate nanoparticles, and obtain the dispersion curves from very low magnetic field up to 11.7 T. In contrast to the relaxivity profiles of Gd chelates, commonly used for clinical applications, which display a plateau and then a decrease for increasing magnetic fields, these nanoparticles provide maximum contrast enhancement for magnetic fields around 1–1.5 T. These field-dependent curves are fitted using the so-called Magnetic Particle (MP) model and the extracted parameters discussed as a function of particle size and composition. We finally comment on the new possibilities offered by this approach. PMID:28317892

  5. Lateral Flow Assay Based on Paper-Hydrogel Hybrid Material for Sensitive Point-of-Care Detection of Dengue Virus.

    PubMed

    Choi, Jane Ru; Yong, Kar Wey; Tang, Ruihua; Gong, Yan; Wen, Ting; Yang, Hui; Li, Ang; Chia, Yook Chin; Pingguan-Murphy, Belinda; Xu, Feng

    2017-01-01

    Paper-based devices have been broadly used for the point-of-care detection of dengue viral nucleic acids due to their simplicity, cost-effectiveness, and readily observable colorimetric readout. However, their moderate sensitivity and functionality have limited their applications. Despite the above-mentioned advantages, paper substrates are lacking in their ability to control fluid flow, in contrast to the flow control enabled by polymer substrates (e.g., agarose) with readily tunable pore size and porosity. Herein, taking the benefits from both materials, the authors propose a strategy to create a hybrid substrate by incorporating agarose into the test strip to achieve flow control for optimal biomolecule interactions. As compared to the unmodified test strip, this strategy allows sensitive detection of targets with an approximately tenfold signal improvement. Additionally, the authors showcase the potential of functionality improvement by creating multiple test zones for semi-quantification of targets, suggesting that the number of visible test zones is directly proportional to the target concentration. The authors further demonstrate the potential of their proposed strategy for clinical assessment by applying it to their prototype sample-to-result test strip to sensitively and semi-quantitatively detect dengue viral RNA from the clinical blood samples. This proposed strategy holds significant promise for detecting various targets for diverse future applications. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Effect of variable tinted spectacle lenses on visual performance in control subjects.

    PubMed

    Lee, Jason E; Stein, Jonathan J; Prevor, Meredith B; Seiple, William H; Holopigian, Karen; Greenstein, Vivienne C; Stenson, Susan M

    2002-04-01

    To evaluate quantitatively the effects of tinted spectacle lenses on visual performance in individuals without visual pathology. Twenty-five subjects were assessed by measuring contrast sensitivity with and without glare. Gray, brown, yellow, green, purple, and blue lens tints were evaluated. Measurements were repeated with each lens tint and with a clear lens, and the order was counterbalanced within and between subjects. Glare was induced with a modified brightness acuity tester. All subjects demonstrated an increase in contrast thresholds under glare conditions for all lens tints. However, purple and blue lens tints resulted in the least amount of contrast threshold increase; the yellow lens tint resulted in the largest contrast threshold increase. Purple and blue lens tints may improve contrast sensitivity in control subjects under glare conditions.

  7. Clinical Outcomes after Binocular Implantation of a New Trifocal Diffractive Intraocular Lens

    PubMed Central

    Kretz, Florian T. A.; Breyer, Detlev; Diakonis, Vasilios F.; Klabe, Karsten; Henke, Franziska; Auffarth, Gerd U.; Kaymak, Hakan

    2015-01-01

    Purpose. To evaluate visual, refractive, and contrast sensitivity outcomes, as well as the incidence of pseudophakic photic phenomena and patient satisfaction after bilateral diffractive trifocal intraocular lens (IOL) implantation. Methods. This prospective nonrandomized study included consecutive patients undergoing cataract surgery with bilateral implantation of a diffractive trifocal IOL (AT LISA tri 839MP, Carl Zeiss Meditec). Distance, intermediate, and near visual outcomes were evaluated as well as the defocus curve and the refractive outcomes 3 months after surgery. Photopic and mesopic contrast sensitivity, patient satisfaction, and halo perception were also evaluated. Results. Seventy-six eyes of 38 patients were included; 90% of eyes showed a spherical equivalent within ±0.50 diopters 3 months after surgery. All patients had a binocular uncorrected distance visual acuity of 0.00 LogMAR or better and a binocular uncorrected intermediate visual acuity of 0.10 LogMAR or better, 3 months after surgery. Furthermore, 85% of patients achieved a binocular uncorrected near visual acuity of 0.10 LogMAR or better. Conclusions. Trifocal diffractive IOL implantation seems to provide an effective restoration of visual function for far, intermediate, and near distances, providing high levels of visual quality and patient satisfaction. PMID:26301104

  8. High-visibility photonic crystal fiber interferometer for ultrasensitive refractometric sensing

    NASA Astrophysics Data System (ADS)

    Cárdenas-Sevilla, Guillermo A.; Fávero, Fernando C.; Finazzi, Vittoria; Villatoro, Joel; Pruneri, Valerio

    2011-09-01

    A simple and compact photonic crystal fiber (PCF) interferometer that operates in reflection mode is proposed for refractive index (RI) sensing. The device consists of a ~12mm-long stub of commercially available PCF (LMA-10) fusion spliced to standard optical fiber (SMF-28). The device reflection spectrum exhibits interference patterns with fringe contrast up to 40 dB. One of the excited modes in the PCF is sensitive to external RI therefore the device can be useful for refractrometry. The shift of the interference pattern can be monitored as a function of the external index. In the operating range, from 1.33 to 1.43, the maximum shift is less than the interferometer period, so there is no-ambiguity in the measurements. The maximum sensitivity and resolution achieved were 735 nm per RI units and 7×10-5, respectively. Another approach to measure the external RI consists of monitoring the reflection power located at the quadrature point of the inference pattern in a properly selected wavelength. Consequently the measuring range is narrower but the resolution is higher, up ~7×10-6, thanks to the high fringe contrast.

  9. Seeing conflict and engaging control: Experience with contrastive language benefits executive function in preschoolers

    PubMed Central

    Doebel, Sabine; Zelazo, Philip David

    2016-01-01

    Engaging executive function often requires overriding a prepotent response in favor of a conflicting but adaptive one. Language may play a key role in this ability by supporting integrated representations of conflicting rules. We tested whether experience with contrastive language that could support such representations benefits executive function in 3-year-old children. Children who received brief experience with language highlighting contrast between objects, attributes, and actions showed greater executive function on two of three ‘conflict’ executive function tasks than children who received experience with contrasting stimuli only and children who read storybooks with the experimenter, controlling for baseline executive function. Experience with contrasting stimuli did not benefit executive function relative to reading books with the experimenter, indicating experience with contrastive language, rather than experience with contrast generally, was key. Experience with contrastive language also boosted spontaneous attention to contrast, consistent with improvements in representing contrast. These findings indicate a role for language in executive function that is consistent with the Cognitive Complexity and Control theory's key claim that coordinating conflicting rules is critical to overcoming perseveration, and suggest new ideas for testing theories of executive function. PMID:27658118

  10. Seeing conflict and engaging control: Experience with contrastive language benefits executive function in preschoolers.

    PubMed

    Doebel, Sabine; Zelazo, Philip David

    2016-12-01

    Engaging executive function often requires overriding a prepotent response in favor of a conflicting but adaptive one. Language may play a key role in this ability by supporting integrated representations of conflicting rules. We tested whether experience with contrastive language that could support such representations benefits executive function in 3-year-old children. Children who received brief experience with language highlighting contrast between objects, attributes, and actions showed greater executive function on two of three 'conflict' executive function tasks than children who received experience with contrasting stimuli only and children who read storybooks with the experimenter, controlling for baseline executive function. Experience with contrasting stimuli did not benefit executive function relative to reading books with the experimenter, indicating experience with contrastive language, rather than experience with contrast generally, was key. Experience with contrastive language also boosted spontaneous attention to contrast, consistent with improvements in representing contrast. These findings indicate a role for language in executive function that is consistent with the Cognitive Complexity and Control theory's key claim that coordinating conflicting rules is critical to overcoming perseveration, and suggest new ideas for testing theories of executive function. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. HCIT Contrast Performance Sensitivity Studies: Simulation Versus Experiment

    NASA Technical Reports Server (NTRS)

    Sidick, Erkin; Shaklan, Stuart; Krist, John; Cady, Eric J.; Kern, Brian; Balasubramanian, Kunjithapatham

    2013-01-01

    Using NASA's High Contrast Imaging Testbed (HCIT) at the Jet Propulsion Laboratory, we have experimentally investigated the sensitivity of dark hole contrast in a Lyot coronagraph for the following factors: 1) Lateral and longitudinal translation of an occulting mask; 2) An opaque spot on the occulting mask; 3) Sizes of the controlled dark hole area. Also, we compared the measured results with simulations obtained using both MACOS (Modeling and Analysis for Controlled Optical Systems) and PROPER optical analysis programs with full three-dimensional near-field diffraction analysis to model HCIT's optical train and coronagraph.

  12. Single-energy non-contrast hepatic steatosis criteria applied to virtual non-contrast images: is it still highly specific and positively predictive?

    PubMed

    Haji-Momenian, S; Parkinson, W; Khati, N; Brindle, K; Earls, J; Zeman, R K

    2018-06-01

    To determine the sensitivity, specificity, and predictive values of single-energy non-contrast hepatic steatosis criteria on dual-energy virtual non-contrast (VNC) images. Forty-eight computed tomography (CT) examinations, which included single-energy non-contrast (TNC) and contrast-enhanced dual-energy CT angiography (CTA) of the abdomen, were enrolled. VNC images were reconstructed from the CTA. Region of interest (ROI) attenuations were measured in the right and left hepatic lobes, spleen, and aorta on TNC and VNC images. The right and left hepatic lobes were treated as separate samples. Steatosis was diagnosed based on TNC liver attenuation of ≤40 HU or liver attenuation index (LAI) of ≤-10 HU, which are extremely specific and predictive for moderate to severe steatosis. The sensitivity, specificity, and predictive values of VNC images for steatosis were calculated. VNC-TNC deviations were correlated with aortic enhancement and patient water equivalent diameter (PWED). Thirty-two liver ROIs met steatosis criteria based on TNC attenuation; VNC attenuation had sensitivity, specificity, and a positive predictive value of 66.7%, 100%, and 100%, respectively. Twenty-one liver ROIs met steatosis criteria based on TNC LAI. VNC LAI had sensitivity, specificity, and positive predictive values of 61.9%, 90.7%, and 65%, respectively. Hepatic and splenic VNC-TNC deviations did not correlate with one another (R 2 =0.08), aortic enhancement (R 2 <0.06) or PWED (R 2 <0.09). Non-contrast hepatic attenuation criteria is extremely specific and positively predictive for moderate to severe steatosis on VNC reconstructions from the arterial phase. Hepatic attenuation performs better than LAI criteria. VNC deviations are independent of aortic enhancement and PWED. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  13. Robo-AO Discovery and Basic Characterization of Wide Multiple Star Systems in the Pleiades, Praesepe, and NGC 2264 Clusters

    NASA Astrophysics Data System (ADS)

    Hillenbrand, Lynne A.; Zhang, Celia; Riddle, Reed L.; Baranec, Christoph; Ziegler, Carl; Law, Nicholas M.; Stauffer, John

    2018-02-01

    We identify and roughly characterize 66 candidate binary star systems in the Pleiades, Praesepe, and NGC 2264 star clusters, based on robotic adaptive optics imaging data obtained using Robo-AO at the Palomar 60″ telescope. Only ∼10% of our imaged pairs were previously known. We detect companions at red optical wavelengths, with physical separations ranging from a few tens to a few thousands of au. A three-sigma contrast curve generated for each final image provides upper limits to the brightness ratios for any undetected putative companions. The observations are sensitive to companions with a maximum contrast of ∼6m at larger separations. At smaller separations, the mean (best) raw contrast at 2″ is 3.ͫ8 (6m), at 1″ is 3.ͫ0 (4.ͫ5), and at 0.″5 is 1.ͫ9 (3m). Point-spread function subtraction can recover nearly the full contrast in the closer separations. For detected candidate binary pairs, we report separations, position angles, and relative magnitudes. Theoretical isochrones appropriate to the Pleiades and Praesepe clusters are then used to determine the corresponding binary mass ratios, which range from 0.2 to 0.9 in q={m}2/{m}1. For our sample of roughly solar-mass (FGK type) stars in NGC 2264 and sub-solar-mass (K and early M-type) primaries in the Pleiades and Praesepe, the overall binary frequency is measured at ∼15.5% ± 2%. However, this value should be considered a lower limit to the true binary fraction within the specified separation and mass ratio ranges in these clusters, given that complex and uncertain corrections for sensitivity and completeness have not been applied.

  14. Structural sensitivity of x-ray Bragg projection ptychography to domain patterns in epitaxial thin films

    DOE PAGES

    Hruszkewycz, S. O.; Zhang, Q.; Holt, M. V.; ...

    2016-10-04

    Bragg projection ptychography (BPP) is a coherent diffraction imaging technique capable of mapping the spatial distribution of the Bragg structure factor in nanostructured thin films. Here, we show that, because these images are projections, the structural sensitivity of the resulting images depends on the film thickness and the aspect ratio and orientation of the features of interest and that image interpretation depends on these factors. Lastly, we model changes in contrast in the BPP reconstructions of simulated PbTiO 3 ferroelectric thin films with meandering 180° stripe domains as a function of film thickness, discuss their origin, and comment on themore » implication of these factors on the design of BPP experiments of general nanostructured films.« less

  15. Psychophysical Measurements of Luminance Contrast Sensitivity and Color Discrimination with Transparent and Blue-Light Filter Intraocular Lenses.

    PubMed

    da Costa, Marcelo Fernandes; Júnior, Augusto Paranhos; Lottenberg, Claudio Luiz; Castro, Leonardo Cunha; Ventura, Dora Fix

    2017-12-01

    The purpose of this study was to measure luminance contrast sensitivity and color vision thresholdfs in normal subjects using a blue light filter lens and transparent intraocular lens material. Monocular luminance grating contrast sensitivity was measured with Psycho for Windows (version 2.36; Cambridge Research Systems) at 3.0, 6.0, 12.0, 20.0, and 30.0 cycles per degree of visual angle (cpd) in 15 normal subjects (eight female), with a mean age of 21.6 years (SD = 3.8 years). Chromatic discrimination was assessed with the Cambridge colour test (CCT) along the protan, deutan, and tritan color confusion axes. Both tests were performed in a darkened room under two situations: with a transparent lens and with blue light filter lens. Subjective impressions were taken by subjects regarding their visual experience under both conditions. No difference was found between the luminance contrast sensitivity measured with transparent and blue light filter. However, 13/15 (87%) of the subjects reported more comfortable vision with the blue filter. In the color vision test, tritan thresholds were significantly higher for the blue filter compared with the transparent filter (p = 0.003). For protan and deutan thresholds no differences were found. Blue-yellow color vision is impaired with the blue light filter, and no impairment occurs with the transparent filter. No significant differences in thresholds were found in the luminance contrast sensitivity comparing the blue light and transparent filters. The impact of short wavelength light filtering on intrinsically photosensitive retinal ganglion cells is also discussed.

  16. Contrast-enhanced swallow study sensitivity for anastomotic leak detection in post-esophagectomy patients.

    PubMed

    Mejía-Rivera, S; Pérez-Marroquín, S A; Cortés-González, R; Medina-Franco, H

    2018-03-07

    Esophagectomy is a highly invasive surgery and one of its postoperative complications is anastomotic leakage, occurring in 53% of cases. The aim of the present study was to determine the sensitivity of the contrast-enhanced swallow study as a method for diagnosing anastomotic leak in patients that underwent esophagectomy. The present retrospective study included the case records of patients that underwent esophagectomy with reconstruction and cervical anastomosis at the Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán within the time frame of January 1, 2000 and May 31, 2006. Demographic, clinical, and laboratory data emphasizing clinical and radiographic anastomotic leak detection were identified. Descriptive statistics were carried out and contrast-enhanced swallow study sensitivity for diagnosing leakage was calculated. Seventy patients were included in the analysis. The mean age of the patients was 50.6 years, 51 of the patients were men (72.86%), and 19 were women (27.14%). Indications for surgery were benign lesion in 29 patients (41.4%) and malignant lesion in 41 (58.6%). A total of 44.3% of the patients presented with a comorbidity, with diabetes mellitus and high blood pressure standing out. Thirty patients (42.85%) presented with anastomotic leak. Contrast-enhanced swallow study sensitivity for leak detection was 43.33%. The diagnostic sensitivity of the contrast-enhanced swallow study was very low. Therefore, we recommend the discontinuation of its routine use as a method for diagnosing anastomotic leaks. Copyright © 2018 Asociación Mexicana de Gastroenterología. Publicado por Masson Doyma México S.A. All rights reserved.

  17. Diffusion properties of conventional and calcium-sensitive MRI contrast agents in the rat cerebral cortex.

    PubMed

    Hagberg, Gisela E; Mamedov, Ilgar; Power, Anthony; Beyerlein, Michael; Merkle, Hellmut; Kiselev, Valerij G; Dhingra, Kirti; Kubìček, Vojtĕch; Angelovski, Goran; Logothetis, Nikos K

    2014-01-01

    Calcium-sensitive MRI contrast agents can only yield quantitative results if the agent concentration in the tissue is known. The agent concentration could be determined by diffusion modeling, if relevant parameters were available. We have established an MRI-based method capable of determining diffusion properties of conventional and calcium-sensitive agents. Simulations and experiments demonstrate that the method is applicable both for conventional contrast agents with a fixed relaxivity value and for calcium-sensitive contrast agents. The full pharmacokinetic time-course of gadolinium concentration estimates was observed by MRI before, during and after intracerebral administration of the agent, and the effective diffusion coefficient D* was determined by voxel-wise fitting of the solution to the diffusion equation. The method yielded whole brain coverage with a high spatial and temporal sampling. The use of two types of MRI sequences for sampling of the diffusion time courses was investigated: Look-Locker-based quantitative T(1) mapping, and T(1) -weighted MRI. The observation times of the proposed MRI method is long (up to 20 h) and consequently the diffusion distances covered are also long (2-4 mm). Despite this difference, the D* values in vivo were in agreement with previous findings using optical measurement techniques, based on observation times of a few minutes. The effective diffusion coefficient determined for the calcium-sensitive contrast agents may be used to determine local tissue concentrations and to design infusion protocols that maintain the agent concentration at a steady state, thereby enabling quantitative sensing of the local calcium concentration. Copyright © 2014 John Wiley & Sons, Ltd.

  18. A comparative study on preprocessing techniques in diabetic retinopathy retinal images: illumination correction and contrast enhancement.

    PubMed

    Rasta, Seyed Hossein; Partovi, Mahsa Eisazadeh; Seyedarabi, Hadi; Javadzadeh, Alireza

    2015-01-01

    To investigate the effect of preprocessing techniques including contrast enhancement and illumination correction on retinal image quality, a comparative study was carried out. We studied and implemented a few illumination correction and contrast enhancement techniques on color retinal images to find out the best technique for optimum image enhancement. To compare and choose the best illumination correction technique we analyzed the corrected red and green components of color retinal images statistically and visually. The two contrast enhancement techniques were analyzed using a vessel segmentation algorithm by calculating the sensitivity and specificity. The statistical evaluation of the illumination correction techniques were carried out by calculating the coefficients of variation. The dividing method using the median filter to estimate background illumination showed the lowest Coefficients of variations in the red component. The quotient and homomorphic filtering methods after the dividing method presented good results based on their low Coefficients of variations. The contrast limited adaptive histogram equalization increased the sensitivity of the vessel segmentation algorithm up to 5% in the same amount of accuracy. The contrast limited adaptive histogram equalization technique has a higher sensitivity than the polynomial transformation operator as a contrast enhancement technique for vessel segmentation. Three techniques including the dividing method using the median filter to estimate background, quotient based and homomorphic filtering were found as the effective illumination correction techniques based on a statistical evaluation. Applying the local contrast enhancement technique, such as CLAHE, for fundus images presented good potentials in enhancing the vasculature segmentation.

  19. Clinical perspectives of hybrid proton-fluorine magnetic resonance imaging and spectroscopy.

    PubMed

    Wolters, Martijn; Mohades, Seyede G; Hackeng, Tilman M; Post, Mark J; Kooi, Marianne E; Backes, Walter H

    2013-05-01

    The number of applications of fluorine 19 (19F) magnetic resonance (MR) imaging and spectroscopy in biomedical and clinical research is steadily growing. The 100% natural abundance of fluorine and its relatively high sensitivity for MR (83% to that of protons) make it an interesting nucleus for a wide range of MR applications. Fluorinated contrast media have a number of advantages over the conventionally used gadolinium-based or iron-based contrast agents. The absence of an endogenous fluorine background intensity in the human body facilitates reliable quantification of fluorinated contrast medium or drugs. Anatomy can be visualized separately with proton MR imaging, creating the application of hybrid hydrogen 1 (1H)/19F MR imaging. The availability of 2 channels (ie, the 1H and 19F channels) enables dual-targeted molecular imaging. Recently, novel developments have emerged on fluorine-based contrast media in preclinical studies and imaging techniques. The developments in fluorine MR seem promising for clinical applications, with contributions in therapy monitoring, assessment of lung function, angiography, and molecular imaging. This review outlines the translation from recent advances in preclinical MR imaging and spectroscopy to future perspectives of clinical hybrid 1H/19/F MR imaging applications.

  20. Acoustic Droplet Vaporization in Biology and Medicine

    PubMed Central

    Pitt, William G.

    2013-01-01

    This paper reviews the literature regarding the use of acoustic droplet vaporization (ADV) in clinical applications of imaging, embolic therapy, and therapeutic delivery. ADV is a physical process in which the pressure waves of ultrasound induce a phase transition that causes superheated liquid nanodroplets to form gas bubbles. The bubbles provide ultrasonic imaging contrast and other functions. ADV of perfluoropentane was used extensively in imaging for preclinical trials in the 1990s, but its use declined rapidly with the advent of other imaging agents. In the last decade, ADV was proposed and explored for embolic occlusion therapy, drug delivery, aberration correction, and high intensity focused ultrasound (HIFU) sensitization. Vessel occlusion via ADV has been explored in rodents and dogs and may be approaching clinical use. ADV for drug delivery is still in preclinical stages with initial applications to treat tumors in mice. Other techniques are still in preclinical studies but have potential for clinical use in specialty applications. Overall, ADV has a bright future in clinical application because the small size of nanodroplets greatly reduces the rate of clearance compared to larger contrast agent bubbles and yet provides the advantages of ultrasonographic contrast, acoustic cavitation, and nontoxicity of conventional perfluorocarbon contrast agent bubbles. PMID:24350267

Top