Visual contrast sensitivity deficits in Bohemian children.
Hudnell, H K; Skalik, I; Otto, D; House, D; Subrt, P; Sram, R
1996-01-01
Visual contrast sensitivity (VCS) tests have been used successfully in medical diagnosis and subclinical neurotoxicity detection. This paper reports VCS measurements in three studies of children in the Czech Republic. Study 1 compared children in standard schools and schools for the learning disabled. Studies 2 and 3 compared children in Teplice, an area in which soft-brown coal combustion produced high levels of pollutants (e.g. Hg, As, SO2, NOx, and aromatic hydrocarbons), with children in areas of low air pollution, Znojmo and/or Prachatice. It was hypothesized that in utero exposure to the combustion products disrupted neurological development (Sram, 1991). The VCS test (Stereo Optical Co.) consisted of circular fields containing sinusoidal gratings at 5 spatial frequencies (1.5-18 cycles/degree) and various levels of contrast. Subjects indicated orientation of the gratings by pointing left, up, or right. Visual acuity and VCS were measured in each eye of 74 children in Study 1,327 second-grade children in Study 2, and 426 fourth-grade children in Study 3. Hair samples were collected in Studies 2 and 3 analyzed for Hg and As content. Children attending schools for the learning disabled scored significantly lower than controls on VCS, whereas visual acuity was normal. The deficit was greatest at mid- to high spatial frequency. In Study 2, significant VCS deficits were seen in exposed second-grade children at low to mid-spatial frequency, even though visual acuity was slightly above control level. Regression analyses showed that VCS had no relationship to As, but a significant negative correlation with hair Hg was observed in the exposed district. However, current Hg levels were higher in Prachatice. VCS deficits were not observed in the fourth-grade students of Teplice in Study 3. The results of Study 1 indicated that behavioral VCS testing in field studies is practical in young, non-English speaking children, and suggested that vision may be compromised in learning-disabled children. Studies 2 and 3 indicated that at these levels, current Hg body-burdens are poor predictors of VCS. If the VCS deficits seen in Study 2 were related to prenatal exposures, the results of Study 3 suggest that they represent a developmental delay. A longitudinal-study design is needed to address this issue.
Thomas, Gregory; Burton, Nancy Clark; Mueller, Charles; Page, Elena; Vesper, Stephen
2012-09-01
The National Institute for Occupational Safety and Health (NIOSH) conducted a health hazard evaluation (HHE) of a water-damaged school in New Orleans (NO), Louisiana. Our aim in this evaluation was to document employee health effects related to exposure to the water-damaged school, and to determine if VCS testing could serve as a biomarker of effect for occupants who experienced adverse health effects in a water-damaged building. NIOSH physicians and staff administered a work history and medical questionnaire, conducted visual contrast sensitivity (VCS) testing, and collected sticky-tape, air, and dust samples at the school. Counting, culturing, and/or a DNA-based technology, called mold-specific quantitative PCR (MSQPCR), were also used to quantify the molds. A similar health and environmental evaluation was performed at a comparable school in Cincinnati, Ohio which was not water-damaged. Extensive mold contamination was documented in the water-damaged school and employees (n = 95) had higher prevalences of work-related rashes and nasal, lower respiratory, and constitutional symptoms than those at the comparison school (n = 110). VCS values across all spatial frequencies were lower among employees at the water-damaged school. Employees exposed to an extensively water-damaged environment reported adverse health effects, including rashes and nasal, lower respiratory, and constitutional symptoms. VCS values were lower in the employees at the water-damaged school, but we do not recommend using it in evaluation of people exposed to mold. Am. J. Ind. Med. 55:844-854, 2012. This article is a U.S. Government work and is in the public domain in the USA. Published 2012 Wiley Periodicals, Inc. This article is a U.S. Government work and is in the public domain in the USA.
Carroll, Will; Lenney, Warren; Wang, Tianshu; Spanel, Patrik; Alcock, Alice; Smith, David
2005-05-01
Pseudomonas aeruginosa (PA) is associated with a distinctive smell produced by a combination of volatile compounds (VCs). Selected ion flow tube mass spectrometry (SIFT-MS) provides a novel and rapid methodology for rapid, accurate detection of trace quantities (parts per billion; ppb) of VCs in air. We studied the VCs produced by different isolates of PA cultures in vitro from patients with cystic fibrosis. Twenty-one patients with cystic fibrosis provided sputum and cough swab samples for culture. These were used to inoculate blood agar (BA) and Pseudomonas-selective media (PSM). These plates were incubated for 48 hr at 37 degrees C inside sealed plastic bags. The air surrounding the samples after 48 hr (headspace) was analyzed using SIFT-MS. PA growth was commonly associated with the production of significant quantities of VCs, notably hydrogen cyanide gas (HCN). This was detectable in the headspace of 15/22 of PA-positive samples. In contrast, it was only seen in the headspace of 1/13 control samples (6 sterile plates and 7 plates with only mixed upper respiratory tract flora). The concentration of HCN was significantly higher above PA-positive samples than above other bacterial growth (P < 0.01), and in our study, levels of HCN greater than 100 ppb were a sensitive (68%) and highly specific (100%) biomarker of PA. SIFT-MS can detect a range of VCs from PA in vitro. HCN may be a specific indicator of PA infection in vivo, and offers promise as a biomarker for noninvasive detection of PA infection by breath analysis. Copyright 2005 Wiley-Liss, Inc
Pfaus, J G; Smith, W J; Byrne, N; Stephens, G
2000-02-01
Copulation with intromission or manual vaginocervical stimulation (VCS) shortens the duration that intact female rats maintain lordosis responding during estrus. The present study examined whether VCS could shorten the duration of both appetitive and consummatory measures of female sexual behavior, and whether these effects occur differentially in time and across different hormone priming intervals. Ovariectomized, sexually experienced female rats were administered subcutaneous injections of estradiol benzoate 48 h and progesterone 4 h, before receiving 50 manual VCSs with a lubricated glass rod distributed over 1 h. Control females received sham VCSs distributed over the same time. The females were then tested for sexual behavior in bilevel chambers with two sexually vigorous males (to one ejaculatory series or 10 min with each male, separated by 5 min) 12, 16, and 20 h after VCS. Prior to the final hormone treatment, different groups of females had been given the same hormone treatment either 28, 14, 7, or 4 days before. In females tested at 28- and 14-day hormone intervals, VCS induced both active and passive rejection responses at 12, 16, and 20 h. In contrast, females that received sham VCS displayed relatively normal sexual behavior at 12 h, although by 16 and 20 h these females displayed active and passive rejection. Females tested at 7- or 4-day intervals displayed normal levels of lordosis at all testing times, regardless of VCS treatment. These data indicate that VCS facilitates rejection responses that precede the decrease in lordosis responsiveness. However, the effects of VCS are dependent on the frequency of hormone priming, suggesting that hormone treatment may block some of the long-term inhibitory effects of VCS on female sexual behavior. Copyright 2000 Academic Press.
Sánchez-López, Ángela María; Baslam, Marouane; De Diego, Nuria; Muñoz, Francisco José; Bahaji, Abdellatif; Almagro, Goizeder; Ricarte-Bermejo, Adriana; García-Gómez, Pablo; Li, Jun; Humplík, Jan F; Novák, Ondřej; Spíchal, Lukáš; Doležal, Karel; Baroja-Fernández, Edurne; Pozueta-Romero, Javier
2016-12-01
It is known that volatile emissions from some beneficial rhizosphere microorganisms promote plant growth. Here we show that volatile compounds (VCs) emitted by phylogenetically diverse rhizosphere and non-rhizhosphere bacteria and fungi (including plant pathogens and microbes that do not normally interact mutualistically with plants) promote growth and flowering of various plant species, including crops. In Arabidopsis plants exposed to VCs emitted by the phytopathogen Alternaria alternata, changes included enhancement of photosynthesis and accumulation of high levels of cytokinins (CKs) and sugars. Evidence obtained using transgenic Arabidopsis plants with altered CK status show that CKs play essential roles in this phenomenon, because growth and flowering responses to the VCs were reduced in mutants with CK-deficiency (35S:AtCKX1) or low receptor sensitivity (ahk2/3). Further, we demonstrate that the plant responses to fungal VCs are light-dependent. Transcriptomic analyses of Arabidopsis leaves exposed to A. alternata VCs revealed changes in the expression of light- and CK-responsive genes involved in photosynthesis, growth and flowering. Notably, many genes differentially expressed in plants treated with fungal VCs were also differentially expressed in plants exposed to VCs emitted by the plant growth promoting rhizobacterium Bacillus subtilis GB03, suggesting that plants react to microbial VCs through highly conserved regulatory mechanisms. © 2016 John Wiley & Sons Ltd.
Human visual function in the North Carolina clinical study on possible estuary-associated syndrome.
Hudnell, H K; House, D; Schmid, J; Koltai, D; Stopford, W; Wilkins, J; Savitz, D A; Swinker, M; Music, S
2001-04-20
The U.S. Environmental Protection Agency assisted the North Carolina Department of Health and Human Services in conducting a study to investigate the potential for an association between fish kills in the North Carolina estuary system and the risk for persistent health effects. Impetus for the study was recent evidence suggesting that estuarine dinoflagellates, including members of the toxic Pfiesteria complex (TPC), P. piscicida and P. schumwayae, may release a toxin(s) that kills fish and adversely affects human health. This report describes one component of the study in which visual system function was assessed. Participants working primarily in estuaries inhabited by TPC or in off-shore waters thought not to contain TPC were studied. The potentially exposed estuary (n = 22) and unexposed offshore (n = 20) workers were matched for age, gender, and education. Visual acuity did not differ significantly between the cohorts, but visual contrast sensitivity (VCS), an indicator of visual pattern-detection ability for stimuli of various sizes, was significantly reduced by about 30% in the estuary relative to the offshore cohort. A further analysis that excluded participants having a history possibly predictive of neuropsychological impairment showed a similar VCS reduction. Additional analyses indicated that differences between the cohorts in age, education, smoking, alcohol consumption, and total time spent on any water did not account for the difference in VCS. Exploratory analyses suggested a possible association between the magnitude of VCS reduction and hours spent in contact with a fish kill. The profile of VCS deficit across stimulus sizes resembled that seen in organic solvent-exposed workers, but an assessment of occupational solvent, and other neurotoxicant, exposures did not indicate differences between the cohorts. These results suggest that factor(s) associated with the North Carolina estuaries, including the possibility of exposure to TPC toxin(s), may impair visual system function.
Mustafi, Devkumar; Ward, Jesse; Dougherty, Urszula; Bissonnette, Marc; Hart, John; Vogt, Stefan; Karczmar, Gregory S.
2016-01-01
Contrast agents that specifically enhance cancers on MRI would allow earlier detection. Vanadyl-based chelates (VCs) selectively enhance rodent cancers on MRI, suggesting selective uptake of VCs by cancers. Here we report X-ray fluorescence microscopy (XFM) of VC uptake by murine colon cancer. Colonic tumors in mice treated with azoxymethane/dextran sulfate sodium were identified by MRI. Then a gadolinium-based contrast agent and a VC were injected I.V.; mice were sacrificed and colons sectioned. VC distribution was sampled at 120 minutes after injection to evaluate the long term accumulation. Gadolinium distribution was sampled at 10 minutes after injection due to its rapid washout. XFM was performed on 72 regions of normal and cancerous colon from 5 normal mice and 4 cancer-bearing mice. XFM showed that all gadolinium was extracellular with similar concentrations in colon cancers and normal colon. In contrast, the average VC concentration was 2-fold higher in cancers vs. normal tissue (p<0.002). Cancers also contained numerous ‘hot spots’ with intracellular VC concentrations 6-fold higher than the concentration in normal colon (p<0.0001). No ‘hot spots’ were detected in normal colon. This is the first direct demonstration that VCs selectively accumulate in cancer cells, and thus may improve cancer detection. PMID:25813904
Gómez-Camarillo, Madaí A; Beyer, Carlos; Lucio, Rosa Angélica; García-Juárez, Marcos; González-Arenas, Aliesha; Camacho-Arroyo, Ignacio; Komisaruk, Barry R; González-Flores, Oscar
2011-05-30
The effect of genital stimulation, either by vaginocervical stimulation (VCS) using a calibrated vaginal probe combined with manual flank stimulation (FS), or by mounts performed by the male, on the hypothalamus and preoptic area concentration of the progesterone receptors A (PR-A) and B (PR-B) was assessed in ovariectomized (ovx) estrogen-primed rats. VCS/FS or stimulation provided by male mounts, even without intromission, significantly decreased PR-B concentration in the hypoythalamus. Down regulation of PR produced by genital stimulation was quantitatively similar to that elicited by progesterone (P) administration. Bilateral or unilateral transection of the pelvic or the pudendal nerves prevented down regulation elicited by VCS/FS. Repeated VCS/FS elicited lordosis behavior in most ovx estrogen primed rats, but the lordosis intensity was lower than that observed in response to P. P administered to ovx estrogen primed rats, induced sequential inhibition, i.e., failure to display estrous behavior in response to a second P injection (24h after the initial P injection). VCS/FS failed to elicit sequential inhibition, since rats responded with normal estrous behavior to the second injection of P. This suggests that down regulation by VCS, by contrast with P, failed to inhibit the subpopulation of PR involved in the facilitation of estrous behavior by P. Copyright © 2011 Elsevier Inc. All rights reserved.
Jones, Sherri Lee; Germé, Katuschia; Graham, M Dean; Roy, Patrick; Gardner Gregory, James; Rosenbaum, Stephanie; Parada, Mayte; Pfaus, James G
2015-09-01
The acute administration of estradiol benzoate (EB) to the ovariectomized (OVX) rat induces low levels of lordosis while sexually appetitive behaviors (e.g., hops, darts, solicitations) are absent, yet the repeated administration of EB results in a behavioral sensitization in which lordosis is potentiated and sexually appetitive behaviors are induced. We have shown that repeated copulation attenuates the sensitization of appetitive sexual behaviors. Here, we assessed which component of male stimulation during copulation is involved in the attenuation. On 8 occasions, sexually experienced OVX Long-Evans rats were treated with 10μgEB and 48h later assigned to one of six groups that differed in their experience on intermediates tests (2-7). One was given repeated access to a male (EB/Male), and another was placed in the copulation chamber alone (EB/Alone) on intermediate tests. Three groups were given one of three somatosensory stimuli by the experimenter: manual flank stimulation (FLS), clitoral stimulation (CLS), or vaginocervical stimulation (VCS). Finally, the control group was left undisturbed in the animal care facility (ACF). Sexual behaviors were measured on Tests 1 and 8. VCS received from the experimenter (VCS) or from the male during copulation (EB/Male) attenuated the magnitude of the sensitization of appetitive sexual behaviors compared with those that were not brought to the testing rooms (ACF), and the effect was most pronounced on sexual solicitations. These results suggest that VCS received during penile intromission inhibits the sensitization of sexually appetitive behaviors by repeated administration of EB. As such, repeated administration of EB may oppose those mechanisms that induce estrous termination, perhaps by sensitizing inhibitory processes within the ventromedial hypothalamus that typically prevent the display of sexual behaviors (i.e., by facilitating disinhibition). Copyright © 2015 Elsevier Inc. All rights reserved.
Huber, J F; Hüsler, J; Zumstein, M D; Ruflin, G; Lüscher, M
2007-01-01
The visual analogue scale (VAS) and Likert scale (LS) are widely used but the patients might have difficulties to work with these scales and there might be errors in calculation. The visual circle scale (VCS) is a graphic construct with a simple grading to augment the understanding and ease for calculation. This study compares the different scales in orthopaedic patients for pain assessment postoperatively. In addition, the scales were rated by the patients for simplicity, understanding and global rating. Included were 65 patients (40 women) with an average age of 66 years with 330 pain assessments and 65 questionnaire ratings. The average pain was LS 42.7, VAS 39.3, VCS 44. The correlation coefficients r (Spearman) between all scales were > 0.89 and the same held also for sensitivity for change. The VCS was the scale preferred by > 50 % of the orthopaedic patients to assess the pain. The VCS is able to measure pain comparably to the known scales (VAS, Likert scale). From the patients point of view it is the preferred scale to work with.
Cheating prevention in visual cryptography.
Hu, Chih-Ming; Tzeng, Wen-Guey
2007-01-01
Visual cryptography (VC) is a method of encrypting a secret image into shares such that stacking a sufficient number of shares reveals the secret image. Shares are usually presented in transparencies. Each participant holds a transparency. Most of the previous research work on VC focuses on improving two parameters: pixel expansion and contrast. In this paper, we studied the cheating problem in VC and extended VC. We considered the attacks of malicious adversaries who may deviate from the scheme in any way. We presented three cheating methods and applied them on attacking existent VC or extended VC schemes. We improved one cheat-preventing scheme. We proposed a generic method that converts a VCS to another VCS that has the property of cheating prevention. The overhead of the conversion is near optimal in both contrast degression and pixel expansion.
Pfaus, James G; Manitt, Colleen; Coopersmith, Carol B
2006-12-30
In the female rat, genitosensory input is conveyed to the central nervous system predominantly through the pelvic, pudendal, and hypogastric nerves. The present study examined the relative contribution of those three nerves in the expression of Fos immunoreactivity within brain regions previously shown to be activated by vaginocervical stimulation (VCS). Bilateral transection of those nerves, or sham neurectomy, was conducted in separate groups of ovariectomized, sexually-experienced females. After recovery, females were primed with estrogen and progesterone and given either 50 manual VCSs with a lubricated glass rod over the course of 1 h. VCS increased the number of neurons expressing Fos immunoreactivity in the medial preoptic area, lateral septum, bed nucleus of the stria terminalis, ventromedial hypothalamus, and medial amygdala of sham neurectomized females. Transection of the pelvic nerve reduced Fos immunoreactivity in the medial preoptic area, bed nucleus of the stria terminalis, ventromedial hypothalamus, and medial amygdala, whereas transection of the pudendal nerve had no effect. In contrast, transection of the hypogastric nerve increased Fos immunoreactivity in the medial preoptic area and lateral septum, whereas transaction of the pelvic nerve increased Fos immunoreactivity in the lateral septum, following VCS. All females given VCS, except those with pelvic neurectomy, displayed a characteristic immobility during each application. These data confirm that the pelvic nerve is largely responsible for the neural and behavioral effects of VCS, and support a separate function for the hypogastric nerve.
Schreiber, Judith S; Hudnell, H Kenneth; Geller, Andrew M; House, Dennis E; Aldous, Kenneth M; Force, Michael S; Langguth, Karyn; Prohonic, Elizabeth J; Parker, Jean C
2002-01-01
Tetrachloroethylene (also called perchloroethylene, or perc), a volatile organic compound, has been the predominant solvent used by the dry-cleaning industry for many years. The U.S. Environmental Protection Agency (EPA) classified perc as a hazardous air pollutant because of its potential adverse impact on human health. Several occupational studies have indicated that chronic, airborne perc exposure adversely affects neurobehavioral functions in workers, particularly visual color discrimination and tasks dependent on rapid visual-information processing. A 1995 study by Altmann and colleagues extended these findings, indicating that environmental perc exposure at a mean level of 4,980 microg/m(3) (median=1,360 microg/m(3)) alters neurobehavioral functions in residents living near dry-cleaning facilities. Although the U.S. EPA has not yet set a reference concentration guideline level for environmental exposure to airborne perc, the New York State Department of Health set an air quality guideline of 100 microg/m(3). In the current residential study, we investigated the potential for perc exposure and neurologic effects, using a battery of visual-system function tests, among healthy members of six families living in two apartment buildings in New York City that contained dry-cleaning facilities on the ground floors. In addition, a day care investigation assessed the potential for perc exposure and effects among workers at a day care center located in the same one-story building as a dry-cleaning facility. Results from the residential study showed a mean exposure level of 778 microg/m(3) perc in indoor air for a mean of 5.8 years, and that perc levels in breath, blood, and urine were 1-2 orders of magnitude in excess of background values. Group-mean visual contrast sensitivity (VCS), a measure of the ability to detect visual patterns, was significantly reduced in the 17 exposed study participants relative to unexposed matched-control participants. The groups did not differ in visual acuity, suggesting that the VCS deficit was of neurologic origin. Healthy workers in the day care investigation were chronically exposed to airborne perc at a mean of 2,150 microg/m(3) for a mean of 4.0 years. Again, group-mean VCS, measured 6 weeks after exposure cessation, was significantly reduced in the nine exposed workers relative to matched controls, and the groups did not differ significantly in visual acuity. These results suggested that chronic, environmental exposure to airborne perc adversely affects neurobehavioral function in healthy individuals. Further research is needed to assess the susceptibility of the young and elderly to perc-induced effects, to determine whether persistent solvent-induced VCS deficits are a risk factor for the development of neurologic disease, and to identify the no observable adverse effect level for chronic, environmental, perc exposure in humans. PMID:12117642
Shen, Tian; Gu, Delin; Zhu, Yihua; Shi, Junwei; Xu, Dongsheng; Cao, Xingjian
2016-08-01
The morphological changes in activated neutrophils associated with antituberculosis drugs can be measured by volume, conductivity, and scatter (VCS) technology on the Coulter LH750 hematology analyzer. We conducted the current study to further validate the clinical usefulness of the neutrophil VCS parameters in predicting drug-induced neutropenia. Peripheral blood samples were collected from 52 patients with drug-induced neutropenia, 309 patients without any abnormal CBC, and 237 healthy controls. The mean neutrophil volume (MNV) with its distribution width (NDW) and the mean neutrophil scatter (MNS) were studied. We observed a significant increase in the MNV and NDW as well as a significant decrease in the MNS in neutropenia patients approximately one week prior to development of neutropenia compared to healthy controls as well as to case controls. In addition, the delta MNV and delta MNS were respectively correlated well with delta absolute neutrophil counts when neutropenia occurred. The ROC curve analyses showed that the MNV、NDW and MNS had larger areas under curves compared to conventional parameters. With a cutoff of 150.15 for the MNV, a sensitivity of 84.4% and specificity of 75.7% were achieved prior to neutropenia. The neutrophil VCS parameters may be clinically useful as potential hematological indicators for predicting antituberculosis drug-induced neutropenia. Copyright © 2016 Elsevier B.V. All rights reserved.
Lévy, F; Keller, M; Cornilleau, F; Moussu, C; Ferreira, G
2010-09-01
Ewes form a selective olfactory memory for their lambs after 2 hr of mother-young interaction following parturition. Mothers will subsequently reject any strange lamb at suckling. The present study investigated whether artificial vaginocervical stimulation (VCS) allows the formation of a selective bond with an unfamiliar lamb and whether it interferes with the maintenance of the bond formed with the familiar lamb. At 2 hr postpartum, mothers were separated from their familiar lamb after having formed a selective bond with it and were given 10 min of mechanical VCS. In the "VCS + lamb" group (n = 24) an unfamiliar lamb was left with the ewe for 2 hr whereas in the "VCS no lamb" group (n = 26) the mother was left alone for the same period of time. Ewes of the "no VCS" group (n = 14) did not receive any VCS. In the majority of animals of the "VCS + lamb" group (23/24) VCS induced a complete acceptance of the unfamiliar lamb without any disruption of the bond previously formed with the familiar lamb. VCS or 2 hr of separation did not disrupt the maintenance of the selective bond initially formed with the familiar lamb since all the ewes of the "VCS no lamb" and "no VCS" groups accepted it at suckling.
Thakur, Vivek; Kush, Preeti; Pandey, Ravi Shankar; Jain, Upendra Kumar; Chandra, Ramesh; Madan, Jitender
2016-04-01
Vincristine sulfate (VCS) is a drug of choice for the treatment of childhood and adult acute lymphocytic leukemia, Hodgkin's, non-Hodgkin's lymphoma as well as solid tumors including sarcomas. However, poor biopharmaceutical and pharmacokinetic traits of VCS like short serum half-life (12 min), high dosing frequency (1.4 mg/m(2) per week for 4 weeks) and extensive protein binding (75%) limit the clinical potential of VCS in cancer therapy. In present investigation, injectable vincristine sulfate loaded dextran microspheres (VCS-Dextran-MSs) were prepared and amalgamated with chitosan-β-glycerophosphate gel (VCS-Dextran-MSs-Gel) to surmount the biopharmaceutical and pharmacokinetic limitations of VCS that consequently induced synergistic sustained release pattern of the drug. Particle size and zeta-potential of VCS-Dextran-MSs were measured to be 6.8 ± 2.4 μm and -18.3 ± 0.11 mV along with the encapsulation efficiency of about 60.4 ± 4.5%. Furthermore, VCS-Dextran-MSs and VCS-Dextran-MSs-Gel exhibited slow release pattern and 94.7% and 95.8% of the drug was released in 72 h and 720 h, respectively. Results from cell viability assay and pharmacokinetic as well as histopathological analysis in mice indicated that VCS-Dextran-MSs-Gel offers superior therapeutic potential and higher AUClast than VCS-Dextran-MSs and drug solution. In conclusion, VCS-Dextran-MSs-Gel warrants further preclinical tumor growth study to scale up the technology. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Laveissière, G.; Degrande, N.; Jaminion, S.; Jutier, C.; Todor, L.; Salvo, R. Di; Hoorebeke, L. Van; Alexa, L. C.; Anderson, B. D.; Aniol, K. A.; Arundell, K.; Audit, G.; Auerbach, L.; Baker, F. T.; Baylac, M.; Berthot, J.; Bertin, P. Y.; Bertozzi, W.; Bimbot, L.; Boeglin, W. U.; Brash, E. J.; Breton, V.; Breuer, H.; Burtin, E.; Calarco, J. R.; Cardman, L. S.; Cavata, C.; Chang, C.-C.; Chen, J.-P.; Chudakov, E.; Cisbani, E.; Dale, D. S.; de Jager, C. W.; de Leo, R.; Deur, A.; D'Hose, N.; Dodge, G. E.; Domingo, J. J.; Elouadrhiri, L.; Epstein, M. B.; Ewell, L. A.; Finn, J. M.; Fissum, K. G.; Fonvieille, H.; Fournier, G.; Frois, B.; Frullani, S.; Furget, C.; Gao, H.; Gao, J.; Garibaldi, F.; Gasparian, A.; Gilad, S.; Gilman, R.; Glamazdin, A.; Glashausser, C.; Gomez, J.; Gorbenko, V.; Grenier, P.; Guichon, P. A. M.; Hansen, J. O.; Holmes, R.; Holtrop, M.; Howell, C.; Huber, G. M.; Hyde, C. E.; Incerti, S.; Iodice, M.; Jardillier, J.; Jones, M. K.; Kahl, W.; Kamalov, S.; Kato, S.; Katramatou, A. T.; Kelly, J. J.; Kerhoas, S.; Ketikyan, A.; Khayat, M.; Kino, K.; Kox, S.; Kramer, L. H.; Kumar, K. S.; Kumbartzki, G.; Kuss, M.; Leone, A.; Lerose, J. J.; Liang, M.; Lindgren, R. A.; Liyanage, N.; Lolos, G. J.; Lourie, R. W.; Madey, R.; Maeda, K.; Malov, S.; Manley, D. M.; Marchand, C.; Marchand, D.; Margaziotis, D. J.; Markowitz, P.; Marroncle, J.; Martino, J.; McCormick, K.; McIntyre, J.; Mehrabyan, S.; Merchez, F.; Meziani, Z. E.; Michaels, R.; Miller, G. W.; Mougey, J. Y.; Nanda, S. K.; Neyret, D.; Offermann, E. A. J. M.; Papandreou, Z.; Perdrisat, C. F.; Perrino, R.; Petratos, G. G.; Platchkov, S.; Pomatsalyuk, R.; Prout, D. L.; Punjabi, V. A.; Pussieux, T.; Quémenér, G.; Ransome, R. D.; Ravel, O.; Real, J. S.; Renard, F.; Roblin, Y.; Rowntree, D.; Rutledge, G.; Rutt, P. M.; Saha, A.; Saito, T.; Sarty, A. J.; Serdarevic, A.; Smith, T.; Smirnov, G.; Soldi, K.; Sorokin, P.; Souder, P. A.; Suleiman, R.; Templon, J. A.; Terasawa, T.; Tiator, L.; Tieulent, R.; Tomasi-Gustaffson, E.; Tsubota, H.; Ueno, H.; Ulmer, P. E.; Urciuoli, G. M.; de Vyver, R. Van; der Meer, R. L. J. Van; Vernin, P.; Vlahovic, B.; Voskanyan, H.; Voutier, E.; Watson, J. W.; Weinstein, L. B.; Wijesooriya, K.; Wilson, R.; Wojtsekhowski, B. B.; Zainea, D. G.; Zhang, W.-M.; Zhao, J.; Zhou, Z.-L.
2009-01-01
We have made the first measurements of the virtual Compton scattering (VCS) process via the H(e, e'p)γ exclusive reaction in the nucleon resonance region, at backward angles. Results are presented for the W-dependence at fixed Q2=1GeV2 and for the Q2 dependence at fixed W near 1.5 GeV. The VCS data show resonant structures in the first and second resonance regions. The observed Q2 dependence is smooth. The measured ratio of H(e, e'p)γ to H(e, e'p)π0 cross sections emphasizes the different sensitivity of these two reactions to the various nucleon resonances. Finally, when compared to real Compton scattering (RCS) at high energy and large angles, our VCS data at the highest W (1.8-1.9 GeV) show a striking Q2 independence, which may suggest a transition to a perturbative scattering mechanism at the quark level.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-05
...,810B] Amended Certification Regarding Eligibility To Apply for Worker Adjustment Assistance; SYMANTEC Corporation, the Enterprise Product and Services Group, SSQ Engineering, VCS and VCS-One Division, Austin, TX; SYMANTEC Corporation, the Enterprise Product and Services Group, SQA Engineering, VCS and VCS-One Division...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-03
.... 75,003 Velsicol Chemical, LLC, Memphis, TN December 15, 2009. True Specialties Corp., Quarles..., TX November 1, 2009. SQA Engineering, VCS and VCS-One Group. 74,810A Symantec Corporation, Mountain View, CA..... November 1, 2009. SQA Engineering, VCS and VCS-One Group. 74,810B Symantec Corporation...
VizieR Online Data Catalog: Second epoch VLBA Calibrator Survey (VCS-II) (Gordon+, 2016)
NASA Astrophysics Data System (ADS)
Gordon, D.; Jacobs, C.; Beasley, A.; Peck, A.; Gaume, R.; Charlot, P.; Fey, A.; Ma, C.; Titov, O.; Boboltz, D.
2016-07-01
Six Very Long Baseline Array (VLBA) calibrator survey campaigns were run between 1994 and 2007 (VCS1, Beasley et al. 2002, cat. J/ApJS/141/13; VCS2, Fomalont et al. 2003, cat. J/AJ/126/2562; VCS3, Petrov et al. 2005, cat. J/AJ/129/1163; VCS4, Petrov et al. 2006, cat. J/AJ/131/1872; VCS5, Kovalev et al. 2007, cat. J/AJ/133/1236; VCS6, Petrov et al. 2008, cat. J/AJ/136/580) We report on the results of a second epoch VLBA Calibrator Survey campaign (VCS-II) in which 2400 VCS sources were re-observed in the X and S bands. The VLBA S/X (S band~2.3GHz and X band~8.6GHz) dual frequency system was used. We used the VLBA RDBE/Mark5C system, which has 16 32MHz channels and records 2 Gbits/s using 2 bit sampling. Due to S-band filters below 2200MHz and above 2400MHz at most of the VLBA antennas, and a broad area of RFI from SiriusXM satellites (2320-2345MHz), only four channels could be deployed in the S band (2220.0, 2252.0, 2284.0, and 2348.0MHz). The other 12 channels were deployed in the X band (8460.0, 8492.0, 8524.0, 8556.0, 8620.0, 8652.0, 8716.0, 8748.0, 8812.0, 8844.0, 8876.0, and 8908.0MHz). We set a target of 300 sources per session, or 2400 total sources for the 8 VLBA sessions. We selected all sources from the Goddard Space Flight Center (GSFC) S/X astrometric/geodetic catalog (available at http://gemini.gsfc.nasa.gov/solutions/ or by following the links at http://lupus.gsfc.nasa.gov/) between -50° and +90° decl. that had been observed in only 1 or 2 sessions as of mid 2013. This amounted to ~2060 sources. To fill out the list, we added ~340 additional sources that had been observed but not detected in the original VCS1-6 analysis. The eight schedules were run between 2014 January and 2015 March (VCS-II-A/BG219A on 2014 01/04 10:04-01/05 10:02; VCS-II-B/BG219B1 on 2014 05/31 17:12-06/01 17:05; VCS-II-D/BG219D on 2014 06/09 09:13-06/10 09:10; VCS-II-C/BG219C on 2014 08/05 13:03-08/06 13:00; VCS-II-E/BG219E on 2014 08/09 00:00-08/09 23:55; VCS-II-F/BG219F on 2014 12/20 01:18-12/21 01:14; VCS-II-H/BG219H on 2015 01/23 23:00-01/24 22:55; VCS-II-I/BG219I on 2015 03/17 07:57-03/18 07:57). Positions and other information for the 2062 re-observed and the 324 new sources are given in Tables 2 and 3. (2 data files).
Martínez-Medina, Ainhoa; Van Wees, Saskia C M; Pieterse, Corné M J
2017-11-01
Root colonization by Trichoderma fungi can trigger induced systemic resistance (ISR). In Arabidopsis, Trichoderma-ISR relies on the transcription factor MYB72, which plays a dual role in the onset of ISR and the activation of Fe uptake responses. Volatile compounds (VCs) from rhizobacteria are important elicitors of MYB72 in Arabidopsis roots. Here, we investigated the mode of action of VCs from Trichoderma fungi in the onset of ISR and Fe uptake responses. VCs from Trichoderma asperellum and Trichoderma harzianum were applied in an in vitro split-plate system with Arabidopsis or tomato seedlings. Locally, Trichoderma-VCs triggered MYB72 expression and molecular, physiological and morphological Fe uptake mechanisms in Arabidopsis roots. In leaves, Trichoderma-VCs primed jasmonic acid-dependent defences, leading to an enhanced resistance against Botrytis cinerea. By using Arabidopsis micrografts of VCs-exposed rootstocks and non-exposed scions, we demonstrated that perception of Trichoderma-VCs by the roots leads to a systemic signal that primes shoots for enhanced defences. Trichoderma-VCs also elicited Fe deficiency responses and shoot immunity in tomato, suggesting that this phenomenon is expressed in different plant species. Our results indicate that Trichoderma-VCs trigger locally a readjustment of Fe homeostasis in roots, which links to systemic elicitation of ISR by priming of jasmonic acid-dependent defences. © 2017 John Wiley & Sons Ltd.
Reuquen, Patricia; Guajardo-Correa, Emanuel; Oróstica, María L; Curotto, Constanza; Parada-Bustamante, Alexis; Cardenas, Hugo; Orihuela, Pedro A
2017-12-01
Vaginocervical stimulation (VCS) induces twice-daily prolactin (PRL) surges resulting in pseudopregnancy in the rat. Furthermore, activation of the extracellular signal-regulated kinase-1/2 (Erk-1/2) is involved in the effect of estradiol (E 2 ) on the Prl gene expression in pituitary cells. Herein, we investigated whether Erk-1/2 signaling is involved in the control of Prl expression in the pituitary of VCS rats and whether VCS regulates the effect of E 2 on Erk-1/2 and Prl in the pituitary. Estrous rats were assigned as control or VCS groups and 0, 6, 12 or 24h later the levels and localization of phosphorylated Erk-1/2 (p-Erk-1/2) were analyzed in the pituitary. The effect of an Erk-1/2 inhibitor PD98059 on the Prl level in the pituitary of control or VCS rats was also analyzed. Other control or VCS rats were treated with E 2 and the level of p-Erk-1/2 and Prl were measured in the pituitary. In control rats, p-Erk-1/2 decreased at 6 and 12h and increased at 24h while Erk-1/2 was phosphorylated at all time points in VCS rats. p-Erk-1/2 was localized only in the anterior pituitary. PD98059 decreased Prl level in VCS, but not in control rats. Estradiol decreased Erk-1/2 phosphorylation although did not change Prl level in the pituitary of control or VCS rats. These findings show that prolonged activation of Erk-1/2 is necessary to induce Prl expression in the pituitary of VCS rats; however, VCS does not influence the role of E 2 on the activation of Erk-1/2 and Prl expression the pituitary. Copyright © 2017 Society for Biology of Reproduction & the Institute of Animal Reproduction and Food Research of Polish Academy of Sciences in Olsztyn. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.
Gould, Oliver; Wieczorek, Tomas; de Lacy Costello, Ben P J; Persad, Raj; Ratcliffe, Norman
2017-09-26
There have been a number of studies in which metal oxide sensors (MOS) have replaced conventional analytical detectors in gas chromatography systems. However, despite the use of these instruments in a range of applications including breath research the sensor responses (i.e. resistance changes w.r.t. concentration of VCs) remain largely unreported. This paper addresses that issue by comparing the response of a metal oxide sensor directly with a mass spectrometer (MS), whereby both detectors are interfaced to the same GC column using an s-swafer. It was demonstrated that the sensitivity of an in-house fabricated ZnO/ SnO2 thick film MOS was superior to a modern MS for the detection of a wide range of volatile compounds (VCs) of different functionalities and masses. Better techniques for detection and quantification of these VCs is valuable, as many of these compounds are commonly reported throughout the scientific literature. This is also the first published report of a combined GC-MS sensor system. These 2 different detector technologies when combined, should enhance discriminatory abilities to aid disease diagnoses using volatiles from e.g. breath, and bodily fluids. 29 chemical standards have been tested using solid phase micro-extraction; 25 of these compounds are found on human breath. In all but 2 instances the sensor exhibited the same or superior limit of detection compared to the MS. 12 stool samples from healthy participants were analysed, the sensor detected, on average 1.6 peaks more per sample than the MS. Similarly analysing the headspace of E. coli broth cultures the sensor detected 6.9 more peaks per sample versus the MS. This greater sensitivity is primarily a function of the superior limits of detection of the metal oxide sensor. This shows that systems based on the combination of chromatography systems with solid state sensors shows promise for a range of applications. © 2017 IOP Publishing Ltd.
Georgescu, Alexandra Livia; Kuzmanovic, Bojana; Roth, Daniel; Bente, Gary; Vogeley, Kai
2014-01-01
High-functioning autism (HFA) is a neurodevelopmental disorder, which is characterized by life-long socio-communicative impairments on the one hand and preserved verbal and general learning and memory abilities on the other. One of the areas where particular difficulties are observable is the understanding of non-verbal communication cues. Thus, investigating the underlying psychological processes and neural mechanisms of non-verbal communication in HFA allows a better understanding of this disorder, and potentially enables the development of more efficient forms of psychotherapy and trainings. However, the research on non-verbal information processing in HFA faces several methodological challenges. The use of virtual characters (VCs) helps to overcome such challenges by enabling an ecologically valid experience of social presence, and by providing an experimental platform that can be systematically and fully controlled. To make this field of research accessible to a broader audience, we elaborate in the first part of the review the validity of using VCs in non-verbal behavior research on HFA, and we review current relevant paradigms and findings from social-cognitive neuroscience. In the second part, we argue for the use of VCs as either agents or avatars in the context of “transformed social interactions.” This allows for the implementation of real-time social interaction in virtual experimental settings, which represents a more sensitive measure of socio-communicative impairments in HFA. Finally, we argue that VCs and environments are a valuable assistive, educational and therapeutic tool for HFA. PMID:25360098
Georgescu, Alexandra Livia; Kuzmanovic, Bojana; Roth, Daniel; Bente, Gary; Vogeley, Kai
2014-01-01
High-functioning autism (HFA) is a neurodevelopmental disorder, which is characterized by life-long socio-communicative impairments on the one hand and preserved verbal and general learning and memory abilities on the other. One of the areas where particular difficulties are observable is the understanding of non-verbal communication cues. Thus, investigating the underlying psychological processes and neural mechanisms of non-verbal communication in HFA allows a better understanding of this disorder, and potentially enables the development of more efficient forms of psychotherapy and trainings. However, the research on non-verbal information processing in HFA faces several methodological challenges. The use of virtual characters (VCs) helps to overcome such challenges by enabling an ecologically valid experience of social presence, and by providing an experimental platform that can be systematically and fully controlled. To make this field of research accessible to a broader audience, we elaborate in the first part of the review the validity of using VCs in non-verbal behavior research on HFA, and we review current relevant paradigms and findings from social-cognitive neuroscience. In the second part, we argue for the use of VCs as either agents or avatars in the context of "transformed social interactions." This allows for the implementation of real-time social interaction in virtual experimental settings, which represents a more sensitive measure of socio-communicative impairments in HFA. Finally, we argue that VCs and environments are a valuable assistive, educational and therapeutic tool for HFA.
MIFT: GIFT Combinatorial Geometry Input to VCS Code
1977-03-01
r-w w-^ H ^ß0318is CQ BRL °RCUMr REPORT NO. 1967 —-S: ... MIFT: GIFT COMBINATORIAL GEOMETRY INPUT TO VCS CODE Albert E...TITLE (and Subtitle) MIFT: GIFT Combinatorial Geometry Input to VCS Code S. TYPE OF REPORT & PERIOD COVERED FINAL 6. PERFORMING ORG. REPORT NUMBER...Vehicle Code System (VCS) called MORSE was modified to accept the GIFT combinatorial geometry package. GIFT , as opposed to the geometry package
Discrimination between sequential and simultaneous virtual channels with electrical hearing
Landsberger, David; Galvin, John J.
2011-01-01
In cochlear implants (CIs), simultaneous or sequential stimulation of adjacent electrodes can produce intermediate pitch percepts between those of the component electrodes. However, it is unclear whether simultaneous and sequential virtual channels (VCs) can be discriminated. In this study, CI users were asked to discriminate simultaneous and sequential VCs; discrimination was measured for monopolar (MP) and bipolar + 1 stimulation (BP + 1), i.e., relatively broad and focused stimulation modes. For sequential VCs, the interpulse interval (IPI) varied between 0.0 and 1.8 ms. All stimuli were presented at comfortably loud, loudness-balanced levels at a 250 pulse per second per electrode (ppse) stimulation rate. On average, CI subjects were able to reliably discriminate between sequential and simultaneous VCs. While there was no significant effect of IPI or stimulation mode on VC discrimination, some subjects exhibited better VC discrimination with BP + 1 stimulation. Subjects’ discrimination between sequential and simultaneous VCs was correlated with electrode discrimination, suggesting that spatial selectivity may influence perception of sequential VCs. To maintain equal loudness, sequential VC amplitudes were nearly double those of simultaneous VCs, presumably resulting in a broader spread of excitation. These results suggest that perceptual differences between simultaneous and sequential VCs might be explained by differences in the spread of excitation. PMID:21895094
Discrimination between sequential and simultaneous virtual channels with electrical hearing.
Landsberger, David; Galvin, John J
2011-09-01
In cochlear implants (CIs), simultaneous or sequential stimulation of adjacent electrodes can produce intermediate pitch percepts between those of the component electrodes. However, it is unclear whether simultaneous and sequential virtual channels (VCs) can be discriminated. In this study, CI users were asked to discriminate simultaneous and sequential VCs; discrimination was measured for monopolar (MP) and bipolar + 1 stimulation (BP + 1), i.e., relatively broad and focused stimulation modes. For sequential VCs, the interpulse interval (IPI) varied between 0.0 and 1.8 ms. All stimuli were presented at comfortably loud, loudness-balanced levels at a 250 pulse per second per electrode (ppse) stimulation rate. On average, CI subjects were able to reliably discriminate between sequential and simultaneous VCs. While there was no significant effect of IPI or stimulation mode on VC discrimination, some subjects exhibited better VC discrimination with BP + 1 stimulation. Subjects' discrimination between sequential and simultaneous VCs was correlated with electrode discrimination, suggesting that spatial selectivity may influence perception of sequential VCs. To maintain equal loudness, sequential VC amplitudes were nearly double those of simultaneous VCs, presumably resulting in a broader spread of excitation. These results suggest that perceptual differences between simultaneous and sequential VCs might be explained by differences in the spread of excitation. © 2011 Acoustical Society of America
Blazquez, Carola; Lee, Jae Seung; Zegras, Christopher
2016-01-01
We examine and compare pedestrian-vehicle collisions and injury outcomes involving school-age children between 5 and 18 years of age in the capital cities of Santiago, Chile, and Seoul, South Korea. We conduct descriptive analysis of the child pedestrian-vehicle collision (P-VC) data (904 collisions for Santiago and 3,505 for Seoul) reported by the police between 2010 and 2011. We also statistically analyze factors associated with child P-VCs, by both incident severity and age group, using 3 regression models: negative binomial, probit, and spatial lag models. Descriptive statistics suggest that child pedestrians in Seoul have a higher risk of being involved in traffic crashes than their counterparts in Santiago. However, in Seoul a greater proportion of children are unharmed as a result of these incidents, whereas more child pedestrians are killed in Santiago. Younger children in Seoul suffer more injuries from P-VCs than in Santiago. The majority of P-VCs in both cities tend to occur in the afternoon and evening, at intersections in Santiago and at midblock locations in Seoul. Our model results suggest that the resident population of children is positively associated with P-VCs in both cities, and school concentrations apparently increase P-VC risk among older children in Santiago. Bus stops are associated with higher P-VCs in Seoul, and subway stations relate to higher P-VCs among older children in Santiago. Zone-level land use mix was negatively related to child P-VCs in Seoul but not in Santiago. Arterial roads are associated with fewer P-VCs, especially for younger children in both cities. A share of collector roads is associated with increased P-VCs in Seoul but fewer P-VCs in Santiago. Hilliness is related to fewer P-VCs in both cities. Differences in these model results for Santiago and Seoul warrant additional analysis, as do the differences in results across model type (negative binomial versus spatial lag models). To reduce child P-VCs, this study suggests the need to assess subway station and bus stop area conditions in Santiago and Seoul, respectively; areas with high density of schools in Santiago; areas with greater concentrations of children in both cities; and collector roads in Seoul.
Vcs.js - Visualization Control System for the Web
NASA Astrophysics Data System (ADS)
Chaudhary, A.; Lipsa, D.; Doutriaux, C.; Beezley, J. D.; Williams, D. N.; Fries, S.; Harris, M. B.
2016-12-01
VCS is a general purpose visualization library, optimized for climate data, which is part of the UV-CDAT system. It provides a Python API for drawing 2D plots such as lineplots, scatter plots, Taylor diagrams, data colored by scalar values, vector glyphs, isocontours and map projections. VCS is based on the VTK library. Vcs.js is the corresponding JavaScript API, designed to be as close as possible to the original VCS Python API and to provide similar functionality for the Web. Vcs.js includes additional functionality when compared with VCS. This additional API is used to introspect data files available on the server and variables available in a data file. Vcs.js can display plots in the browser window. It always works with a server that reads a data file, extracts variables from the file and subsets the data. From this point, two alternate paths are possible. First the system can render the data on the server using VCS producing an image which is send to the browser to be displayed. This path works for for all plot types and produces a reference image identical with the images produced by VCS. This path uses the VTK-Web library. As an optimization, usable in certain conditions, a second path is possible. Data is packed, and sent to the browser which uses a JavaScript plotting library, such as plotly, to display the data. Plots that work well in the browser are line-plots, scatter-plots for any data and many other plot types for small data and supported grid types. As web technology matures, more plots could be supported for rendering in the browser. Rendering can be done either on the client or on the server and we expect that the best place to render will change depending on the available web technology, data transfer costs, server management costs and value provided to users. We intend to provide a flexible solution that allows for both client and server side rendering and a meaningful way to choose between the two. We provide a web-based user interface called vCdat which uses Vcs.js as its visualization library. Our paper will discuss the principles guiding our design choices for Vcs.js, present our design in detail and show a sample usage of the library.
Development of Vertical Cable Seismic System for Hydrothermal Deposit Survey (2) - Feasibility Study
NASA Astrophysics Data System (ADS)
Asakawa, E.; Murakami, F.; Sekino, Y.; Okamoto, T.; Mikada, H.; Takekawa, J.; Shimura, T.
2010-12-01
In 2009, Ministry of Education, Culture, Sports, Science and Technology(MEXT) started the survey system development for Hydrothermal deposit. We proposed the Vertical Cable Seismic (VCS), the reflection seismic survey with vertical cable above seabottom. VCS has the following advantages for hydrothermal deposit survey. . (1) VCS is an effective high-resolution 3D seismic survey within limited area. (2) It achieves high-resolution image because the sensors are closely located to the target. (3) It avoids the coupling problems between sensor and seabottom that cause serious damage of seismic data quality. (4) Various types of marine source are applicable with VCS such as sea-surface source (air gun, water gun etc.) , deep-towed or ocean bottom sources. (5) Autonomous recording system. Our first experiment of 2D/3D VCS surveys has been carried out in Lake Biwa, JAPAN. in November 2009. The 2D VCS data processing follows the walk-away VSP, including wave field separation and depth migration. The result gives clearer image than the conventional surface seismic. Prestack depth migration is applied to 3D data to obtain good quality 3D depth volume. Uncertainty of the source/receiver poisons in water causes the serious problem of the imaging. We used several transducer/transponder to estimate these positions. The VCS seismic records themselves can also provide sensor position using the first break of each trace and we calibrate the positions. We are currently developing the autonomous recording VCS system and planning the trial experiment in actual ocean to establish the way of deployment/recovery and the examine the position through the current flow in November, 2010. The second VCS survey will planned over the actual hydrothermal deposit with deep-towed source in February, 2011.
Explaining Verification Conditions
NASA Technical Reports Server (NTRS)
Deney, Ewen; Fischer, Bernd
2006-01-01
The Hoare approach to program verification relies on the construction and discharge of verification conditions (VCs) but offers no support to trace, analyze, and understand the VCs themselves. We describe a systematic extension of the Hoare rules by labels so that the calculus itself can be used to build up explanations of the VCs. The labels are maintained through the different processing steps and rendered as natural language explanations. The explanations can easily be customized and can capture different aspects of the VCs; here, we focus on their structure and purpose. The approach is fully declarative and the generated explanations are based only on an analysis of the labels rather than directly on the logical meaning of the underlying VCs or their proofs. Keywords: program verification, Hoare calculus, traceability.
Vertical Cable Seismic (VCS) Survey for SMS exploration in Izena Cauldron, Okinawa-Trough
NASA Astrophysics Data System (ADS)
Asakawa, Eiichi; Murakami, Fumitoshi; Tsukahara, Hitoshi; Mizohata, Shigeharu; Tara, Kenji
2015-04-01
In 2014, the Japanese government started the Cross-ministerial Strategic Innovation Promotion Program (SIP), which includes 'New-generation Offshore Exploration Techniques' as an area of interest. We proposed the Vertical Cable Seismic (VCS) survey technique for this program, especially for the exploration of Seafloor Massive Sulfides (SMS). VCS is a reflection seismic method that uses hydrophone arrays vertically moored from the seafloor to record acoustic waves generated by various acoustic sources. This method is useful to delineate detailed structures in a spatially-limited area below the seabed in the deep sea where conventional surface seismic is not effective. We have been developing an autonomous VCS system with the financial support of the Japanese government since 2009. We have carried out several VCS surveys and completed our VCS system. Izena Cauldron, Okinawa Trough is one of the most promising SMS areas around Japan. There are two high potential areas, the north and south mound. We carried out the first VCS survey around the north mound in 2011 and the second survey around the south mound in 2013 respectively. The first VCS survey in Izena Cauldron was carried out using a GI gun in September, 2011, with the objective of surveying the large-scale and deeper structure of the hydrothermal system. The water depth was 1,500-1,600m. Four VCS systems were deployed. The shooting lines covered an area of 9 km x 9 km with a shooting interval of about 25m and line spacing of 200m to 400m. In the second survey, we used a high-voltage sparker. The objective is to explore very shallow parts to delineate very thin SMS deposits. The survey area was about 4 km x 4km with a 12.5 m shooting interval and 100m to 200m line spacing. Three VCS systems were deployed in this survey. The result of the first GI gun VCS survey was a 3D PSDM volume of the subsurface structure. It extends 2,000m horizontally and down to 1,500m in depth. Further, by re-processing the data with a higher resolution to focus the very shallow parts, we found that this survey has enough potential to delineate the SMS deposits itself. In the second high-voltage sparker VCS survey we obtained high resolution field records and a very high resolution 3D volume down to 150m over an area of 400m x 200m. These results successfully delineated sub-seabed structures that suggest the existence of reflections about 30m beneath the seabed. This suggests the top interface of a buried SMS deposit. The detailed results of the both surveys are consistent with the information from a well drilled in the Izena Cauldron by JOGMEC These VCS survey results provide us useful SMS exploration information, and demonstrate that VCS is a suitable reflection seismic method to obtain high resolution 3D volumes just below the seabed. We consider our VCS system to have high potential to delineate SMS structures. The system will continue to be developed as part of the SIP project, along with other geophysical exploration techniques such as EM, magnetic and gravity.
NASA Astrophysics Data System (ADS)
Lipsa, D.; Chaudhary, A.; Williams, D. N.; Doutriaux, C.; Jhaveri, S.
2017-12-01
Climate Data Analysis Tools (UV-CDAT, https://uvcdat.llnl.gov) is a data analysis and visualization software package developed at Lawrence Livermore National Laboratory and designed for climate scientists. Core components of UV-CDAT include: 1) Community Data Management System (CDMS) which provides I/O support and a data model for climate data;2) CDAT Utilities (GenUtil) that processes data using spatial and temporal averaging and statistic functions; and 3) Visualization Control System (VCS) for interactive visualization of the data. VCS is a Python visualization package primarily built for climate scientists, however, because of its generality and breadth of functionality, it can be a useful tool to other scientific applications. VCS provides 1D, 2D and 3D visualization functions such as scatter plot and line graphs for 1d data, boxfill, meshfill, isofill, isoline for 2d scalar data, vector glyphs and streamlines for 2d vector data and 3d_scalar and 3d_vector for 3d data. Specifically for climate data our plotting routines include projections, Skew-T plots and Taylor diagrams. While VCS provided a user-friendly API, the previous implementation of VCS relied on slow performing vector graphics (Cairo) backend which is suitable for smaller dataset and non-interactive graphics. LLNL and Kitware team has added a new backend to VCS that uses the Visualization Toolkit (VTK) as its visualization backend. VTK is one of the most popular open source, multi-platform scientific visualization library written in C++. Its use of OpenGL and pipeline processing architecture results in a high performant VCS library. Its multitude of available data formats and visualization algorithms results in easy adoption of new visualization methods and new data formats in VCS. In this presentation, we describe recent contributions to VCS that includes new visualization plots, continuous integration testing using Conda and CircleCI, tutorials and examples using Jupyter notebooks as well as upgrades that we are planning in the near future which will improve its ease of use and reliability and extend its capabilities.
Development of Vertical Cable Seismic System
NASA Astrophysics Data System (ADS)
Asakawa, E.; Murakami, F.; Sekino, Y.; Okamoto, T.; Ishikawa, K.; Tsukahara, H.; Shimura, T.
2011-12-01
In 2009, Ministry of Education, Culture, Sports, Science and Technology(MEXT) started the survey system development for Hydrothermal deposit. We proposed the Vertical Cable Seismic (VCS), the reflection seismic survey with vertical cable above seabottom. VCS has the following advantages for hydrothermal deposit survey. (1) VCS is an efficient high-resolution 3D seismic survey in limited area. (2) It achieves high-resolution image because the sensors are closely located to the target. (3) It avoids the coupling problems between sensor and seabottom that cause serious damage of seismic data quality. (4) Because of autonomous recording system on sea floor, various types of marine source are applicable with VCS such as sea-surface source (GI gun etc.) , deep-towed or ocean bottom source. Our first experiment of 2D/3D VCS surveys has been carried out in Lake Biwa, JAPAN, in November 2009. The 2D VCS data processing follows the walk-away VSP, including wave field separation and depth migration. Seismic Interferometry technique is also applied. The results give much clearer image than the conventional surface seismic. Prestack depth migration is applied to 3D data to obtain good quality 3D depth volume. Seismic Interferometry technique is applied to obtain the high resolution image in the very shallow zone. Based on the feasibility study, we have developed the autonomous recording VCS system and carried out the trial experiment in actual ocean at the water depth of about 400m to establish the procedures of deployment/recovery and to examine the VC position or fluctuation at seabottom. The result shows that the VC position is estimated with sufficient accuracy and very little fluctuation is observed. Institute of Industrial Science, the University of Tokyo took the research cruise NT11-02 on JAMSTEC R/V Natsushima in February, 2011. In the cruise NT11-02, JGI carried out the second VCS survey using the autonomous VCS recording system with the deep towed source provided by Institute of Industrial Science, the University of Tokyo. It generates high frequency acoustic waves around 1kHz. The acquired VCS data clearly shows the reflections and currently being processed for imaging the subsurface structure.
Vertical Cable Seismic Survey for SMS exploration
NASA Astrophysics Data System (ADS)
Asakawa, Eiichi; Murakami, Fumitoshi; Tsukahara, Hotoshi; Mizohata, Shigeharu
2014-05-01
The Vertical Cable Seismic (VCS) survey is one of the reflection seismic methods. It uses hydrophone arrays vertically moored from the seafloor to record acoustic waves generated by sea-surface, deep-towed or ocean bottom sources. Analyzing the reflections from the sub-seabed, we could look into the subsurface structure. Because the VCS is an efficient high-resolution 3D seismic survey method for a spatially-bounded area, we proposed it for the SMS survey tool development program that the Ministry of Education, Culture, Sports, Science and Technology (MEXT) started in 2009. We have been developing the VCS survey system, including not only data acquisition hardware but data processing and analysis technique. We carried out several VCS surveys combining with surface towed source, deep towed source and ocean bottom source. The water depths of these surveys are from 100m up to 2100 m. Through these experiments, our VCS data acquisition system has been also completed. But the data processing techniques are still on the way. One of the most critical issues is the positioning in the water. The uncertainty in the positions of the source and of the hydrophones in water degraded the quality of subsurface image. GPS navigation system is available on sea surface, but in case of deep-towed source or ocean bottom source, the accuracy of shot position with SSBL/USBL is not sufficient for the very high-resolution imaging. We have developed a new approach to determine the positions in water using the travel time data from the source to VCS hydrophones. In 2013, we have carried out the second VCS survey using the surface-towed high-voltage sparker and ocean bottom source in the Izena Cauldron, which is one of the most promising SMS areas around Japan. The positions of ocean bottom source estimated by this method are consistent with the VCS field records. The VCS data with the sparker have been processed with 3D PSTM. It gives the very high resolution 3D volume deeper than two hundred meters. Our VCS system has been demonstrated as a promising survey tool for the SMS exploration.
ERIC Educational Resources Information Center
O'Meara, Bernard; Petzall, Stanley
2009-01-01
Purpose: The research presented here attempts to identify and analyse the reported selection criteria used in the appointment of Australian vice-chancellors (VCs) and to contrast this with the selection criteria actually used. Design/methodology/approach: Contemporary research into the nature, role and purpose of section criteria in appointment…
Gabner, Simone; Häusler, Gabriele; Böck, Peter
2017-06-01
Core areas in voluminous pieces of permanent cartilage are metabolically supplied via vascular canals (VCs). We studied cartilage corrosion and removal of matrix degradation products during the development of VCs in nose and rib cartilage of piglets. Conventional staining methods were used for glycosaminoglycans, immunohistochemistry was performed to demonstrate collagens types I and II, laminin, Ki-67, von Willebrand factor, VEGF, macrophage marker MAC387, S-100 protein, MMPs -2,-9,-13,-14, and their inhibitors TIMP1 and TIMP2. VCs derived from connective tissue buds that bulged into cartilage matrix ("perichondrial papillae", PPs). Matrix was corroded at the tips of PPs or resulting VCs. Connective tissue stromata in PPs and VCs comprised an axial afferent blood vessel, peripherally located wide capillaries, fibroblasts, newly synthesized matrix, and residues of corroded cartilage matrix (collagen type II, acidic proteoglycans). Multinucleated chondroclasts were absent, and monocytes/macrophages were not seen outside the blood vessels. Vanishing acidity characterized areas of extracellular matrix degradation ("preresorptive layers"), from where the dismantled matrix components diffused out. Leached-out material stained in an identical manner to intact cartilage matrix. It was detected in the stroma and inside capillaries and associated downstream veins. We conclude that the delicate VCs are excavated by endothelial sprouts and fibroblasts, whilst chondroclasts are specialized to remove high volumes of mineralized cartilage. VCs leading into permanent cartilage can be formed by corrosion or inclusion, but most VCs comprise segments that have developed in either of these ways. Anat Rec, 300:1067-1082, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Shoemaker, Ritchie C; House, Dennis E
2005-01-01
The human health risk for chronic illnesses involving multiple body systems following inhalation exposure to the indoor environments of water-damaged buildings (WDBs) has remained poorly characterized and the subject of intense controversy. The current study assessed the hypothesis that exposure to the indoor environments of WDBs with visible microbial colonization was associated with illness. The study used a cross-sectional design with assessments at five time points, and the interventions of cholestyramine (CSM) therapy, exposure avoidance following therapy, and reexposure to the buildings after illness resolution. The methodological approach included oral administration of questionnaires, medical examinations, laboratory analyses, pulmonary function testing, and measurements of visual function. Of the 21 study volunteers, 19 completed assessment at each of the five time points. Data at Time Point 1 indicated multiple symptoms involving at least four organ systems in all study participants, a restrictive respiratory condition in four participants, and abnormally low visual contrast sensitivity (VCS) in 18 participants. Serum leptin levels were abnormally high and alpha melanocyte stimulating hormone (MSH) levels were abnormally low. Assessments at Time Point 2, following 2 weeks of CSM therapy, indicated a highly significant improvement in health status. Improvement was maintained at Time Point 3, which followed exposure avoidance without therapy. Reexposure to the WDBs resulted in illness reacquisition in all participants within 1 to 7 days. Following another round of CSM therapy, assessments at Time Point 5 indicated a highly significant improvement in health status. The group-mean number of symptoms decreased from 14.9+/-0.8 S.E.M. at Time Point 1 to 1.2+/-0.3 S.E.M., and the VCS deficit of approximately 50% at Time Point 1 was fully resolved. Leptin and MSH levels showed statistically significant improvement. The results indicated that CSM was an effective therapeutic agent, that VCS was a sensitive and specific indicator of neurologic function, and that illness involved systemic and hypothalamic processes. Although the results supported the general hypothesis that illness was associated with exposure to the WDBs, this conclusion was tempered by several study limitations. Exposure to specific agents was not demonstrated, study participants were not randomly selected, and double-blinding procedures were not used. Additional human and animal studies are needed to confirm this conclusion, investigate the role of complex mixtures of bacteria, fungi, mycotoxins, endotoxins, and antigens in illness causation, and characterize modes of action. Such data will improve the assessment of human health risk from chronic exposure to WDBs.
Hernández-González, Marisela; Reynoso-Orozco, Orlando; Guevara, Miguel Angel; García Abascal, Diego Radberto Chapa; Ågmo, Anders
2016-12-01
The influence of the duration of vaginocervical stimulation (VCS) on the electroencephalographic activity (EEG) of medial amygdala (MeA) and prefrontal cortex (PFC) in rats during proestrus-estrus (P-E) and diestrus (D) was examined. Using a glass syringe plunger, a constant force of 300g was exerted against the cervix during 60s. Relative power (RP) and correlation of three EEG band frequencies were compared between the first and last 30s intervals of VCS. A higher RP of the 4-7Hz band and a lower RP of the fast frequencies were observed in the MeA and PFC in P-E females during the first 30s of VCS as compared to the last 30s. Only during P-E, a higher interamygdaline correlation in the 8-12Hz band and a lower correlation in the 13-21Hz band during the first 30s were observed. Similarly, a higher interamygdaline correlation in the 8-12Hz band was observed during the first 30s of VCS during P-E as compared to D. During the last 30s of VCS there was no difference between phases. The VCS evoked EEG changes in the MeA that varied between phases of the estrous cycle and depended on the duration of the stimulation. These effects could be associated with the quantification processes of VCS that has been proposed to occur in the amygdala. These findings show differential responsiveness of the MeA and PFC according to the amount of VCS received, and that the response varies according to the estrous cycle. Copyright © 2016 Elsevier B.V. All rights reserved.
Design principles for engaging and retaining virtual citizen scientists.
Wald, Dara M; Longo, Justin; Dobell, A R
2016-06-01
Citizen science initiatives encourage volunteer participants to collect and interpret data and contribute to formal scientific projects. The growth of virtual citizen science (VCS), facilitated through websites and mobile applications since the mid-2000s, has been driven by a combination of software innovations and mobile technologies, growing scientific data flows without commensurate increases in resources to handle them, and the desire of internet-connected participants to contribute to collective outputs. However, the increasing availability of internet-based activities requires individual VCS projects to compete for the attention of volunteers and promote their long-term retention. We examined program and platform design principles that might allow VCS initiatives to compete more effectively for volunteers, increase productivity of project participants, and retain contributors over time. We surveyed key personnel engaged in managing a sample of VCS projects to identify the principles and practices they pursued for these purposes and led a team in a heuristic evaluation of volunteer engagement, website or application usability, and participant retention. We received 40 completed survey responses (33% response rate) and completed a heuristic evaluation of 20 VCS program sites. The majority of the VCS programs focused on scientific outcomes, whereas the educational and social benefits of program participation, variables that are consistently ranked as important for volunteer engagement and retention, were incidental. Evaluators indicated usability, across most of the VCS program sites, was higher and less variable than the ratings for participant engagement and retention. In the context of growing competition for the attention of internet volunteers, increased attention to the motivations of virtual citizen scientists may help VCS programs sustain the necessary engagement and retention of their volunteers. © 2016 Society for Conservation Biology.
Development of Vertical Cable Seismic System (2)
NASA Astrophysics Data System (ADS)
Asakawa, E.; Murakami, F.; Tsukahara, H.; Ishikawa, K.
2012-12-01
The vertical cable seismic is one of the reflection seismic methods. It uses hydrophone arrays vertically moored from the seafloor to record acoustic waves generated by surface, deep-towed or ocean bottom sources. Analyzing the reflections from the sub-seabed, we could look into the subsurface structure. This type of survey is generally called VCS (Vertical Cable Seismic). Because VCS is an efficient high-resolution 3D seismic survey method for a spatially-bounded area, we proposed the method for the hydrothermal deposit survey tool development program that the Ministry of Education, Culture, Sports, Science and Technology (MEXT) started in 2009. We are now developing a VCS system, including not only data acquisition hardware but data processing and analysis technique. Our first experiment of VCS surveys has been carried out in Lake Biwa, JAPAN in November 2009 for a feasibility study. Prestack depth migration is applied to the 3D VCS data to obtain a high quality 3D depth volume. Based on the results from the feasibility study, we have developed two autonomous recording VCS systems. After we carried out a trial experiment in the actual ocean at a water depth of about 400m and we carried out the second VCS survey at Iheya Knoll with a deep-towed source. In this survey, we could establish the procedures for the deployment/recovery of the system and could examine the locations and the fluctuations of the vertical cables at a water depth of around 1000m. The acquired VCS data clearly shows the reflections from the sub-seafloor. Through the experiment, we could confirm that our VCS system works well even in the severe circumstances around the locations of seafloor hydrothermal deposits. We have carried out two field surveys in 2011. One is a 3D survey with a boomer for a high-resolution surface source and the other one for an actual field survey in the Izena Cauldron an active hydrothermal area in the Okinawa Trough. Through these surveys, we have confirmed that the uncertainty in the locations of the source and of the hydrophones in water could lower the quality of subsurface image. It is, therefore, strongly necessary to develop a total survey system that assures an accurate positioning and a deployment techniques. In case of shooting on sea surface, GPS navigation system are available, but in case of deep-towed source or ocean bottom source, the accuracy of shot position with SSBL/USBL is not sufficient for the very high-resolution imaging as requested for the SMS survey. We will incorporate the accurate LBL navigation systems with VCs. The LBL navigation system has been developed by IIS of the University of Tokyo. The error is estimated less than 10cm at the water depth of 3000m. Another approach is that the shot points can be calculated using the first break of the VCS after the VCS locations are estimated by slant-ranging from the sea surface. Our VCS system has been designed as a survey tool for hydrothermal deposit, but it will be also applicable for deep water site surveys or geohazard assessment such as active faults.
Vertical Cable Seismic Survey for Hydrothermal Deposit
NASA Astrophysics Data System (ADS)
Asakawa, E.; Murakami, F.; Sekino, Y.; Okamoto, T.; Ishikawa, K.; Tsukahara, H.; Shimura, T.
2012-04-01
The vertical cable seismic is one of the reflection seismic methods. It uses hydrophone arrays vertically moored from the seafloor to record acoustic waves generated by surface, deep-towed or ocean bottom sources. Analyzing the reflections from the sub-seabed, we could look into the subsurface structure. This type of survey is generally called VCS (Vertical Cable Seismic). Because VCS is an efficient high-resolution 3D seismic survey method for a spatially-bounded area, we proposed the method for the hydrothermal deposit survey tool development program that the Ministry of Education, Culture, Sports, Science and Technology (MEXT) started in 2009. We are now developing a VCS system, including not only data acquisition hardware but data processing and analysis technique. Our first experiment of VCS surveys has been carried out in Lake Biwa, JAPAN in November 2009 for a feasibility study. Prestack depth migration is applied to the 3D VCS data to obtain a high quality 3D depth volume. Based on the results from the feasibility study, we have developed two autonomous recording VCS systems. After we carried out a trial experiment in the actual ocean at a water depth of about 400m and we carried out the second VCS survey at Iheya Knoll with a deep-towed source. In this survey, we could establish the procedures for the deployment/recovery of the system and could examine the locations and the fluctuations of the vertical cables at a water depth of around 1000m. The acquired VCS data clearly shows the reflections from the sub-seafloor. Through the experiment, we could confirm that our VCS system works well even in the severe circumstances around the locations of seafloor hydrothermal deposits. We have, however, also confirmed that the uncertainty in the locations of the source and of the hydrophones could lower the quality of subsurface image. It is, therefore, strongly necessary to develop a total survey system that assures a accurate positioning and a deployment techniques. We have carried out two field surveys in FY2011. One is a 3D survey with a boomer for a high-resolution surface source and the other one for an actual field survey in the Izena Cauldron an active hydrothermal area in the Okinawa Trough. Through these surveys, the VCS will become a practical exploration tool for the exploration of seafloor hydrothermal deposits.
Yao, Ruyu; Heinrich, Michael; Wang, Zigui; Weckerle, Caroline S
2018-06-14
Goji (fruits of Lycium barbarum L. and L. chinense Mill., Solanaceae) have been used as a traditional food and medicine for hundreds of years in Asian countries and are now consumed globally. Quality of herbal medicines is critical for safe use and has been shown to be affected by value chains. Using a value chain (VC) framework, we aim at understanding the influence of different VC types on goji quality and revenue of stakeholders. Participant observation and semi-structured interviews were conducted during five months of fieldwork in the main production areas in China with a total of 65 stakeholders. Quality of goji, behaviour and financial performance of stakeholders was documented and analysed for different VCs. Ten different types of VCs were identified. VCs with vertical integration and horizontal collaboration were found to have a more coherent quality control and better goji quality as well as improved stakeholders' financial performance. Vertical integration at different levels was found for independent farmer-based VCs, horizontal collaboration was found in the cooperative-based VCs. Full vertically integrated VCs were found in large-scale production. Goji quality and stakeholders' revenues are linked with different types of VCs which mirror stakeholders' behaviour driven by target markets. Considering their positive influence on quality and revenues, well-developed vertically integrated value chains are likely to become more important in the near future. Copyright © 2018. Published by Elsevier B.V.
Filling the gap of existing MWA-VCS archival data
NASA Astrophysics Data System (ADS)
Xue, M.; Bhat, R.; Tremblay, S.; Ord, S.; Sobey, C.; Kirsten, F.
2017-01-01
Since July 2014, around 110 hours of high time resolution voltage data observed by MWA Voltage Capture System (VCS; Tremblay et al. 2015) have been archived on tapes in the Pawsey Supercomputing Centre. Except some short duration test data and calibration data, the total amount of the observation data which have a duration longer than 400 s is 84 hours. These data cover a significant portion of a lot of the Southern sky and could be used for many science purposes including radio pulsars census and fast radio bursts (FRBs) searching. But there are still some 'holes' in the sky that we do not have VCS archival data for yet. We are proposing a set of MWA-VCS drift scan observations of 3 hours to fill some of these 'holes' and help provide a more complete MWA-VCS data set. We will also census known (cataloged) pulsars in these areas. These observations would be performed between 170-200 MHz. This project will form part of the PhD program of Mengyao Xue.
Visually Coupled Systems (VCS): The Virtual Panoramic Display (VPD) System
NASA Technical Reports Server (NTRS)
Kocian, Dean F.
1992-01-01
The development and impact is described of new visually coupled system (VCS) equipment designed to support engineering and human factors research in the military aircraft cockpit environment. VCS represents an advanced man-machine interface (MMI). Its potential to improve aircrew situational awareness seems enormous, but its superiority over the conventional cockpit MMI has not been established in a conclusive and rigorous fashion. What has been missing is a 'systems' approach to technology advancement that is comprehensive enough to produce conclusive results concerning the operational viability of the VCS concept and verify any risk factors that might be involved with its general use in the cockpit. The advanced VCS configuration described here, was ruggedized for use in military aircraft environments and was dubbed the Virtual Panoramic Display (VPD). It was designed to answer the VCS portion of the systems problem, and is implemented as a modular system whose performance can be tailored to specific application requirements. The overall system concept and the design of the two most important electronic subsystems that support the helmet mounted parts, a new militarized version of the magnetic helmet mounted sight and correspondingly similar helmet display electronics, are discussed in detail. Significant emphasis is given to illustrating how particular design features in the hardware improve overall system performance and support research activities.
Development of Vertical Cable Seismic System (3)
NASA Astrophysics Data System (ADS)
Asakawa, E.; Murakami, F.; Tsukahara, H.; Mizohata, S.; Ishikawa, K.
2013-12-01
The VCS (Vertical Cable Seismic) is one of the reflection seismic methods. It uses hydrophone arrays vertically moored from the seafloor to record acoustic waves generated by surface, deep-towed or ocean bottom sources. Analyzing the reflections from the sub-seabed, we could look into the subsurface structure. Because VCS is an efficient high-resolution 3D seismic survey method for a spatially-bounded area, we proposed the method for the hydrothermal deposit survey tool development program that the Ministry of Education, Culture, Sports, Science and Technology (MEXT) started in 2009. We are now developing a VCS system, including not only data acquisition hardware but data processing and analysis technique. We carried out several VCS surveys combining with surface towed source, deep towed source and ocean bottom source. The water depths of the survey are from 100m up to 2100m. The target of the survey includes not only hydrothermal deposit but oil and gas exploration. Through these experiments, our VCS data acquisition system has been completed. But the data processing techniques are still on the way. One of the most critical issues is the positioning in the water. The uncertainty in the positions of the source and of the hydrophones in water degraded the quality of subsurface image. GPS navigation system are available on sea surface, but in case of deep-towed source or ocean bottom source, the accuracy of shot position with SSBL/USBL is not sufficient for the very high-resolution imaging. We have developed another approach to determine the positions in water using the travel time data from the source to VCS hydrophones. In the data acquisition stage, we estimate the position of VCS location with slant ranging method from the sea surface. The deep-towed source or ocean bottom source is estimated by SSBL/USBL. The water velocity profile is measured by XCTD. After the data acquisition, we pick the first break times of the VCS recorded data. The estimated positions of shot points and receiver points in the field include the errors. We use these data as initial guesses, we invert iteratively shot and receiver positions to match the travel time data. After several iterations we could finally estimate the most probable positions. Integration of the constraint of VCS hydrophone positions, such as the spacing is 10m, can accelerate the convergence of the iterative inversion and improve results. The accuracy of the estimated positions from the travel time date is enough for the VCS data processing.
Ishihara, Kanako; Saito, Mieko; Shimokubo, Natsumi; Muramatsu, Yasukazu; Maetani, Shigeki; Tamura, Yutaka
2014-03-01
To explore the prevalence and molecular characteristics of methicillin-resistant Staphylococcus aureus (MRSA) in veterinary medical practices, MRSA carriage was tested among 96 veterinarians (Vets), 70 veterinary technicians (VTs) and 292 dogs with which they had contact at 71 private veterinary clinics (VCs) in Hokkaido, Japan. MRSA isolates were obtained from 22 Vets [22.9%] and 7 VTs [10%]. The prevalence of MRSA among Vets was as high as that found in an academic veterinary hospital in our previous study. In contrast, only two blood donor dogs and one dog with liver disease (1.0%, 3/292) yielded MRSA. All MRSA-positive dogs were reared or treated in different VCs, in each of which at least one veterinary staff member carrying MRSA worked. Sequence types (ST) identified by multilocus sequence typing, spa types, and SCCmec types for canine MRSA isolates (ST5-spa t002-SCCmec II [from two dogs] or ST30-spa t021-SCCmec IV [from a dog]) were concordant with those from veterinary staff members in the same clinics as the MRSA-positive dogs, with which they had potentially had contact. Most MRSA isolates from veterinary staff were the same genotype (SCCmec type II and spa type t002) as a major hospital-acquired MRSA clone in Japan. The remaining MRSA was the same genotypes as domestic and foreign community-associated MRSA. Measures against MRSA infection should be provided in private VCs. © 2014 The Societies and Wiley Publishing Asia Pty Ltd.
Yin, Pengxian; Meng, Feng; Liu, Qing; An, Rui; Cai, Jing; Du, Guangyuan
2018-03-30
A vulnerability curve (VC) describes the extent of xylem cavitation resistance. Centrifuges have been used to generate VCs for decades via static- and flow-centrifuge methods. Recently, the validity of the centrifuge techniques has been questioned. Researchers have hypothesized that the centrifuge techniques might yield unreliable VCs due to the open-vessel artifact. However, other researchers reject this hypothesis. The focus of the dispute is centred on whether exponential VCs are more reliable when the static-centrifuge method is used than with the flow-centrifuge method. To further test the reliability of the centrifuge technique, two centrifuges were manufactured to simulate the static- and flow-centrifuge methods. VCs of three species with open vessels of known lengths were constructed using the two centrifuges. The results showed that both centrifuge techniques produced invalid VCs for Robinia because the water flow through stems under mild tension in centrifuges led to an increasing loss of water conductivity. Additionally, the injection of water in the flow-centrifuge exacerbated the loss of water conductivity. However, both centrifuge techniques yielded reliable VCs for Prunus, regardless of the presence of open vessels in the tested samples. We conclude that centrifuge techniques can be used in species with open vessels only when the centrifuge produces a VC that matches the bench-dehydration VC. This article is protected by copyright. All rights reserved.
Does vascular stapling improve compliance of vascular anastomoses?
Stansby, G; Knez, P; Berwanger, C S; Nelson, K; Reichert, V; Schmitz-Rixen, T
2001-01-01
Elastic properties of vessel walls are altered by vascular anastomoses. Such alterations may lead to neointimal hyperplasia, which is a common cause of reocclusion following vascular surgery. The severity of paraanastomotic hypercompliant zones and anastomotic compliance drop depend on suturing material and on elastic properties of the anastomotic vessel segments. This study compares paraanastomotic hypercompliance and anastomotic compliance drop when using a new vascular closure system (VCS) and a conventional, continuous suture line in the preparation of end-to-end anastomoses. Compliance of artery-artery, vein-artery, and polytetrafluoroethylene-artery anastomoses was measured in an artificial circulation system at mean pressures of 60, 90, and 120 mm Hg, comparing conventional suturing and the VCS. When using the VCS for vein-artery anastomoses, significantly less postanastomotic hypercompliance was achieved at mean pressures of 60 mm Hg (14.2 +/-3.8% above remote postanastomotic area), compared to suture (55.1 +/-14.8%, p<0.05). At 90 mm Hg, respective values were 11.0 +/-2.3% for VCS and 54.7 +/-10.1% for suture, p<0.01. At 120 mm Hg, in polytetrafluoroethylene-artery anastomoses, the anastomotic compliance drop was significantly less when using the continuous suture line (93.9 +/-1.1% below remote postanastomotic compliance), compared to VCS (97.2 +/-0.2%, p<0.05). Compared to conventional suturing, use of the VCS reduced postanastomotic hypercompliance in vein-artery anastomoses.
Metaproteome of the viral concentrates from the deep chlorophyll maximum of the South China Sea
NASA Astrophysics Data System (ADS)
Xie, Zhang-Xian; Chen, Feng; Zhang, Shu-Feng; Wang, Ming-Hua; Zhang, Hao; Kong, Ling-Fen; Dai, Min-Han; Hong, Hua-Sheng; Lin, Lin; Wang, Da-Zhi
2016-04-01
Viral concentrates (VCs) have been commonly used for studying viral diversity, viral metagenomics and virus-host interactions in the natural ecosystem. However, the protein characteristics of VCs have not been explored. Here, we applied shotgun proteomics to characterize the proteins of VCs collected from the oligotrophic deep chlorophyll maximum of the South China Sea. We found that 34% of the identified proteins were assigned to the viruses, mainly being those of SAR11 related bacteria, cyanobacteria and picophytoeukaryotes. The remaining 66% were non-viral proteins mostly originating from diverse bacteria, such as SAR324, SAR11 and the Alteromonadales, and were functionally dominated by transport, translation, sulfur metabolism and one-carbon metabolism. Among the non-viral proteins, 28% were extracellular proteins and 10% were identified exclusively in the VCs, suggesting that non-viral entities might exist in the VCs. This study demonstrated that metaproteomics provides a valuable avenue to explore not only the diversity and structure of a viral community but also the novel ecological functions affiliated with microbes in the natural environment.
75 FR 65151 - Marine Vapor Control Systems
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-21
...The Coast Guard proposes to increase maritime domain safety by revising existing safety regulations for facility and vessel vapor control systems (VCSs). The proposed changes would make VCS requirements more compatible with new Federal and State environmental requirements, reflect industry advancements in VCS technology, and codify the standards for the design and operation of a VCS at tank barge cleaning facilities. These changes would increase the safety of operations by regulating the design, installation, and use of VCSs, but would not require anyone to install or use VCSs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hinz, Nick; Coolbaugh, Mark; Shevenell, Lisa
There are currently 74 productive geothermal systems associated with volcanic centers (VCs) in arcs globally, including actively producing systems, past producing systems, and systems with successful flow tests. The total installed or tested capacity of these 74 geothermal systems is 7,605 MWe, ranging from 0.7 MWe each at Copahue, Chile and Barkhatnaya Sopka, Kamchatka to 795 MWe, Larderello, Italy, and averaging 90.5 MWe per system. These 74 productive VCs constitute 10% of 732 VCs distributed across more than a dozen major arcs around the world. The intra-arc (within-arc) tectonic setting is highly variable globally, ranging from extension to transtension, transpression,more » or compression. Furthermore, the shear strain associated with oblique plate convergence can be accommodated by either intra-arc or arc-marginal deformation. The structural-tectonic settings of these 74 productive VCs were characterized to add to a global catalog of parameters to help guide future exploration, development, and regional resource potential.« less
VCS: Tool for Visualizing Copy Number Variation and Single Nucleotide Polymorphism.
Kim, HyoYoung; Sung, Samsun; Cho, Seoae; Kim, Tae-Hun; Seo, Kangseok; Kim, Heebal
2014-12-01
Copy number variation (CNV) or single nucleotide phlyorphism (SNP) is useful genetic resource to aid in understanding complex phenotypes or deseases susceptibility. Although thousands of CNVs and SNPs are currently avaliable in the public databases, they are somewhat difficult to use for analyses without visualization tools. We developed a web-based tool called the VCS (visualization of CNV or SNP) to visualize the CNV or SNP detected. The VCS tool can assist to easily interpret a biological meaning from the numerical value of CNV and SNP. The VCS provides six visualization tools: i) the enrichment of genome contents in CNV; ii) the physical distribution of CNV or SNP on chromosomes; iii) the distribution of log2 ratio of CNVs with criteria of interested; iv) the number of CNV or SNP per binning unit; v) the distribution of homozygosity of SNP genotype; and vi) cytomap of genes within CNV or SNP region.
NASA Technical Reports Server (NTRS)
Merino, F.; Oneill, R. F.
1980-01-01
The Cryogenic Fluid Management Experiment (CFME) was analyzed to assess the feasibility and advisability of deleting the vapor cooled shield (VCS) from the baseline CFME insulation and pressure control system. Two alternate concepts of CFME insulation and pressure control, neither of which incorporated the VCS, were investigated. The first concept employed a thermodynamic vent system (TVS) to throttle the flow through an internal wall mounted heat exchanger (HX) within the pressure vessel to decrease boiloff and pressure rise rate, while the second concept utilized a TVS without an internal heat exchanger. Only the first concept was viable. Its performance was assessed for a seven day mission and found to be satisfactory. It was also concluded that VCS development costs would be greater than for an internal HX installation. Based upon the above comparisons, the HX was recommended as a replacement for the VCS.
Gould, Oliver; Wieczorek, Tom; de Lacy Costello, Ben; Persad, Raj; Ratcliffe, Norman
2017-12-06
There have been a number of studies in which metal oxide sensors (MOS) have replaced conventional analytical detectors in gas chromatography systems. However, despite the use of these instruments in a range of applications including breath research the sensor responses (i.e. resistance changes w.r.t. concentration of VCs) remain largely unreported. This paper addresses that issue by comparing the response of a metal oxide sensor directly with a mass spectrometer (MS), whereby both detectors are interfaced to the same GC column using an s-swafer. It was demonstrated that the sensitivity of an in-house fabricated ZnO/SnO 2 thick film MOS was superior to a modern MS for the detection of a wide range of volatile compounds (VCs) of different functionalities and masses. Better techniques for detection and quantification of these VCs is valuable, as many of these compounds are commonly reported throughout the scientific literature. This is also the first published report of a combined GC-MS sensor system. These two different detector technologies when combined, should enhance discriminatory abilities to aid disease diagnoses using volatiles from e.g. breath, and bodily fluids. Twenty-nine chemical standards have been tested using solid phase micro-extraction; 25 of these compounds are found on human breath. In all but two instances the sensor exhibited the same or superior limit of detection compared to the MS. Twelve stool samples from healthy participants were analysed; the sensor detected, on average 1.6 peaks more per sample than the MS. Similarly, analysing the headspace of E. coli broth cultures the sensor detected 6.9 more peaks per sample versus the MS. This greater sensitivity is primarily a function of the superior limits of detection of the metal oxide sensor. This shows that systems based on the combination of chromatography systems with solid state sensors shows promise for a range of applications.
Williams, Virginia P.; Bishop-Fitzpatrick, Lauren; Lane, James D.; Gwyther, Lisa P.; Ballard, Edna L.; Vendittelli, Analise P.; Hutchins, Tiffany C.; Williams, Redford B.
2010-01-01
Objective To determine whether video-based coping skills (VCS) training with telephone coaching reduces psychosocial and biological markers of distress in primary caregivers of a relative with Alzheimer’s Disease or related dementia (ADRD) Methods A controlled clinical trial was conducted with 116 ADRD caregivers who were assigned, alternately as they qualified for the study, to a Wait List control condition or the VCS training arm in which they viewed two modules/week of a version of the Williams LifeSkills Video adapted for ADRD family care contexts, did the exercises and homework for each module presented in an accompanying Workbook, and received one telephone coaching call per week for five weeks on each week’s two modules. Questionnaire-assessed depressive symptoms, state and trait anger and anxiety, perceived stress, hostility, caregiver self-efficacy, salivary cortisol across the day and before and after a stress protocol, and blood pressure and heart rate during a stress protocol were assessed prior to VCS training, seven weeks after training was completed and at three and six months follow-up. Results Compared to controls, participants who received VCS training plus telephone coaching showed significantly greater improvements in depressive symptoms, trait anxiety, perceived stress, and average systolic and diastolic blood pressure that were maintained over the six-month follow-up period. Conclusions VCS training augmented by telephone coaching reduced psychosocial and biological indicators of distress in ADRD caregivers. Future studies should determine the long-term benefits to mental and physical health from this intervention. PMID:20978227
Larrazolo-López, A; Kendrick, K M; Aburto-Arciniega, M; Arriaga-Avila, V; Morimoto, S; Frias, M; Guevara-Guzmán, R
2008-03-27
The ability of vaginocervical stimulation (VCS) to promote olfactory social recognition memory at different stages of the ovarian cycle was investigated in female rats. A juvenile social recognition paradigm was used and memory retention tested at 30 and 300 min after an adult was exposed to a juvenile during three 4-min trials. Results showed that an intact social recognition memory was present at 30 min in animals with or without VCS and at all stages of the estrus cycle. However, whereas no animals in any stage of the estrus cycle showed retention of the specific recognition memory at 300 min, those in the proestrus/estrus phase that received VCS 10 min before the trial started did. In vivo microdialysis studies showed that there was a significant release of oxytocin after VCS in the olfactory bulb during proestrus. There was also increased oxytocin immunoreactivity within the olfactory bulb after VCS in proestrus animals compared with diestrus ones. Furthermore, when animals received an infusion of an oxytocin antagonist directly into the olfactory bulb, or a systemic administration of alpha or beta noradrenaline-antagonists, they failed to show evidence for maintenance of a selective olfactory recognition memory at 300 min. Animals with vagus or pelvic nerve section also showed no memory retention when tested after 300 min. These results suggest that VCS releases oxytocin in the olfactory bulb to enhance the social recognition memory and that this may be due to modulatory actions on noradrenaline release. The vagus and pelvic nerves are responsible for carrying the information from the pelvic area to the CNS.
Safari Science: Assessing the reliability of citizen science data for wildlife surveys
Steger, Cara; Butt, Bilal; Hooten, Mevin B.
2017-01-01
Protected areas are the cornerstone of global conservation, yet financial support for basic monitoring infrastructure is lacking in 60% of them. Citizen science holds potential to address these shortcomings in wildlife monitoring, particularly for resource-limited conservation initiatives in developing countries – if we can account for the reliability of data produced by volunteer citizen scientists (VCS).This study tests the reliability of VCS data vs. data produced by trained ecologists, presenting a hierarchical framework for integrating diverse datasets to assess extra variability from VCS data.Our results show that while VCS data are likely to be overdispersed for our system, the overdispersion varies widely by species. We contend that citizen science methods, within the context of East African drylands, may be more appropriate for species with large body sizes, which are relatively rare, or those that form small herds. VCS perceptions of the charisma of a species may also influence their enthusiasm for recording it.Tailored programme design (such as incentives for VCS) may mitigate the biases in citizen science data and improve overall participation. However, the cost of designing and implementing high-quality citizen science programmes may be prohibitive for the small protected areas that would most benefit from these approaches.Synthesis and applications. As citizen science methods continue to gain momentum, it is critical that managers remain cautious in their implementation of these programmes while working to ensure methods match data purpose. Context-specific tests of citizen science data quality can improve programme implementation, and separate data models should be used when volunteer citizen scientists' variability differs from trained ecologists' data. Partnerships across protected areas and between protected areas and other conservation institutions could help to cover the costs of citizen science programme design and implementation.
Reddy, Chaitan; Pennington, David; Stern, Harvey
2012-02-01
The achievement of patency of the microvascular anastomosis in free flap surgery is dependent on a number of factors, central to which is atraumatic handling of the vessel lumen, and intimal apposition. Initial laboratory studies demonstrating the superiority of the non-penetrating vascular closure staple (VCS - Anastoclip ®) were followed by our report in 1999 on a series of free flaps. There is still a paucity of data in the literature on the use of non-penetrating devices for microvascular anastomosis, and our review gives evidence to support the routine use of the VCS in microsurgical free flap surgery. We now report on its successful use over a thirteen year period in 819 free flap reconstructions. Our data indicates the VCS device to be as effective as sutured anastomoses in free tissue transfer surgery. There is also statistically significant data (Barnard's Exact Test) to demonstrate a higher vascular patency rate of the VCS device over sutured anastomoses when sub group analysis is performed. 'Take-back' revision rates were lower amongst flaps that employed VCS use. For arterial anastomoses, this equated to 3/654(0.05%) vs 4/170(2.4%) with hand-sewn anastomoses (p = 0.02). Similarly, for venous anastomoses the 'take-back' revision rate was 7/661(1.1%) vs 8/165(4.8%) with hand-sewn anastomoses (p = 0.003). Furthermore, the major advantage of the VCS is reduction in anastomosis time, from approximately 25 min per anastomosis for sutures to between five and 10 min for staples. Copyright © 2011 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Jean, Guillaume; Bresson, Eric; Terrat, Jean-Claude; Vanel, Thierry; Hurot, Jean-Marc; Lorriaux, Christie; Mayor, Brice; Chazot, Charles
2009-03-01
Vascular calcifications (VCs) are frequently observed in chronic kidney disease (CKD) and haemodialysis (HD) patients. They have been associated with numerous factors, particularly hyperphosphataemia, excess calcium load, hypertension and increased mortality rate. The purpose of this study is to measure VCs in long-HD patients with good blood pressure and phosphate control, with the occasional use of sevelamer, using a plain radiological score to identify the associated factors and effects on the 1-year survival rate. We studied HD patients from one centre using a semi-quantitative score ranging from 0 to 3 according to the severity and extent of VCs. The following patients' characteristics were compared according to their VC scores: medical history, treatments, blood pressure, standard biological data, fibroblast growth factor (FGF) 23, osteoprotegerin (OPG), whole PTH, beta-crosslaps, bone alkaline phosphatases and bone mineral density scores. One-year survival analyses were also performed. Among the 250 HD patients of the centre, 161 were studied; the mean age was 67.2 +/- 13 years, 45% of the subjects were females, 35% were diabetics, and they had been on dialysis for between 1-486 months (median: 45 months) with a 3 x 5-3 x 8 h dialysis schedule using 1.5 mmol/l dialysate calcium and providing a mean 2.25 +/- 0.5 Kt/V. Only 17% of the patients were free from VCs and 11% had severe VCs. The factors associated with VCs were classified into 'classic' (age, diabetes, male gender, tobacco use, inflammation, more frequent warfarin treatment and peripheral vascular and cardiac diseases) and 'non-traditional' (higher FGF-23 and OPG serum levels, low albumin serum levels and low alfacalcidol and CaCO(3) use). In logistic regression, only age, diabetes and FGF-23 serum levels were associated with VC scores of 2 and 3. The patients with a score of 3 had a higher 1-year mortality rate (RR 2.1; P = 0.01) as compared to patients with a 0 score. A plain radiological score showed the high prevalence (83%) of VCs in HD patients in spite of a long and intensive dialysis strategy and adherence to guidelines. The main associated factors were classic factors such as ageing and diabetes. No relationship was found with blood pressure and phosphataemia that remained well controlled in long dialysis; the association with FGF-23 serum levels may aggregate some non-traditional risk factors. The harmful effects of VCs on survival require their systematic assessment and optimization of the potentially modifiable associated factors in CKD and HD patients.
Transcription factor ETV1 is essential for rapid conduction in the heart.
Shekhar, Akshay; Lin, Xianming; Liu, Fang-Yu; Zhang, Jie; Mo, Huan; Bastarache, Lisa; Denny, Joshua C; Cox, Nancy J; Delmar, Mario; Roden, Dan M; Fishman, Glenn I; Park, David S
2016-12-01
Rapid impulse propagation in the heart is a defining property of pectinated atrial myocardium (PAM) and the ventricular conduction system (VCS) and is essential for maintaining normal cardiac rhythm and optimal cardiac output. Conduction defects in these tissues produce a disproportionate burden of arrhythmic disease and are major predictors of mortality in heart failure patients. Despite the clinical importance, little is known about the gene regulatory network that dictates the fast conduction phenotype. Here, we have used signal transduction and transcriptional profiling screens to identify a genetic pathway that converges on the NRG1-responsive transcription factor ETV1 as a critical regulator of fast conduction physiology for PAM and VCS cardiomyocytes. Etv1 was highly expressed in murine PAM and VCS cardiomyocytes, where it regulates expression of Nkx2-5, Gja5, and Scn5a, key cardiac genes required for rapid conduction. Mice deficient in Etv1 exhibited marked cardiac conduction defects coupled with developmental abnormalities of the VCS. Loss of Etv1 resulted in a complete disruption of the normal sodium current heterogeneity that exists between atrial, VCS, and ventricular myocytes. Lastly, a phenome-wide association study identified a link between ETV1 and bundle branch block and heart block in humans. Together, these results identify ETV1 as a critical factor in determining fast conduction physiology in the heart.
Transcription factor ETV1 is essential for rapid conduction in the heart
Shekhar, Akshay; Lin, Xianming; Liu, Fang-Yu; Zhang, Jie; Mo, Huan; Bastarache, Lisa; Denny, Joshua C.; Cox, Nancy J.; Delmar, Mario; Roden, Dan M.; Fishman, Glenn I.; Park, David S.
2016-01-01
Rapid impulse propagation in the heart is a defining property of pectinated atrial myocardium (PAM) and the ventricular conduction system (VCS) and is essential for maintaining normal cardiac rhythm and optimal cardiac output. Conduction defects in these tissues produce a disproportionate burden of arrhythmic disease and are major predictors of mortality in heart failure patients. Despite the clinical importance, little is known about the gene regulatory network that dictates the fast conduction phenotype. Here, we have used signal transduction and transcriptional profiling screens to identify a genetic pathway that converges on the NRG1-responsive transcription factor ETV1 as a critical regulator of fast conduction physiology for PAM and VCS cardiomyocytes. Etv1 was highly expressed in murine PAM and VCS cardiomyocytes, where it regulates expression of Nkx2-5, Gja5, and Scn5a, key cardiac genes required for rapid conduction. Mice deficient in Etv1 exhibited marked cardiac conduction defects coupled with developmental abnormalities of the VCS. Loss of Etv1 resulted in a complete disruption of the normal sodium current heterogeneity that exists between atrial, VCS, and ventricular myocytes. Lastly, a phenome-wide association study identified a link between ETV1 and bundle branch block and heart block in humans. Together, these results identify ETV1 as a critical factor in determining fast conduction physiology in the heart. PMID:27775552
Exploring the Antecedents of Trust in Virtual Communities
ERIC Educational Resources Information Center
Hsu, Meng-Hsiang; Chang, Chun-Ming; Yen, Chia-Hui
2011-01-01
Although previous research has established that interpersonal trust and system trust are critical in shaping individual behaviour in virtual settings, the two perspectives have not been examined by IS researchers in virtual communities (VCs) simultaneously. Drawing from prior literature on trust and VCs, a research model for understanding the…
AN EXPLORATION OF THE STATISTICAL SIGNATURES OF STELLAR FEEDBACK
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boyden, Ryan D.; Offner, Stella S. R.; Koch, Eric W.
2016-12-20
All molecular clouds are observed to be turbulent, but the origin, means of sustenance, and evolution of the turbulence remain debated. One possibility is that stellar feedback injects enough energy into the cloud to drive observed motions on parsec scales. Recent numerical studies of molecular clouds have found that feedback from stars, such as protostellar outflows and winds, injects energy and impacts turbulence. We expand upon these studies by analyzing magnetohydrodynamic simulations of molecular clouds, including stellar winds, with a range of stellar mass-loss rates and magnetic field strengths. We generate synthetic {sup 12}CO(1–0) maps assuming that the simulations aremore » at the distance of the nearby Perseus molecular cloud. By comparing the outputs from different initial conditions and evolutionary times, we identify differences in the synthetic observations and characterize these using common astrostatistics. We quantify the different statistical responses using a variety of metrics proposed in the literature. We find that multiple astrostatistics, including the principal component analysis, the spectral correlation function, and the velocity coordinate spectrum (VCS), are sensitive to changes in stellar mass-loss rates and/or time evolution. A few statistics, including the Cramer statistic and VCS, are sensitive to the magnetic field strength. These findings demonstrate that stellar feedback influences molecular cloud turbulence and can be identified and quantified observationally using such statistics.« less
33 CFR 154.2103 - Facility requirements for vessel vapor overpressure and vacuum protection.
Code of Federal Regulations, 2014 CFR
2014-07-01
... HAZARDOUS MATERIAL IN BULK Marine Vapor Control Systems Transfer Facilities-Vcs Design and Installation... rate, unless there is experimental data for actual vapor growth for turbulent transferring under the... vapor growth. (b) A facility VCS must be designed to prevent the pressure in a vessel's cargo tanks from...
33 CFR 154.2104 - Pigging system.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Pigging system. 154.2104 Section... Facilities-Vcs Design and Installation § 154.2104 Pigging system. (a) If a pigging system is used to clear... system (VCS), the pigging system must be designed with the following safety features: (1) A bypass loop...
Biller, Elżbieta; Boselli, Emanuele; Obiedziński, Mieczysław; Karpiński, Piotr; Waszkiewicz-Robak, Bożena
2016-11-01
Raw pork neck cutlets were marinated in an aqueous solution of acetic acid (pH4, 24h, 4°C) without (M) or with 1% (w/w) of glucose. The control (K) was formed by non-treated raw pork neck. The cutlets were then broiled (185°C, 30min). In all K cutlets, significant higher amounts of volatile compounds (VCs) were developed after broiling than the other samples. Significant more aldehydes and alcohols were present in the inner parts than in the surface. The correlation between surface and internal layers was high only for aldehydes. Marinating decreased the differences among VCs and led to the standardization of the processed meat. The addition of glucose to the marinade led to more volatile aldehydes, carboxylic acids, esters, furan, pyran, pyrazine, pyrrol and pyridine derivatives than in M samples. Several (53) specific VCs explained the differences among the surface samples related to the marinating process. However, only 16 VCs explained the variance among the inner parts. Copyright © 2016 Elsevier Ltd. All rights reserved.
2012-01-01
Background Patients have typically received health care through face-to-face encounters. However, expansion of electronic communication and electronic health records (EHRs) provide alternative means for patient and physicians to interact. Electronic consultations may complement regular healthcare by providing “better, faster, cheaper” processes for diagnosing, treating, and monitoring health conditions. Virtual consultation between physicians may provide a method of streamlining care, potentially saving patients the time and expense of added visits. The purpose of this study was to compare physician usage and patient satisfaction with virtual consultations (VCs) with traditional consultations (TCs) facilitated within an EHR. Methods We conducted an observational case–control survey study within Kaiser Permanente, Colorado. A sample of patients who had VCs requested by physicians (N = 270) were matched with patients who had TCs requested by physicians (N = 270), by patient age, gender, reason for the consult, and specialty department. These patients (VC and TC), were invited to participate in a satisfaction survey. In addition, 205 primary care physicians who submitted a VC or TC were surveyed. Results During the study period, 58,146 VC or TC were requested (TC = 96.3%). Patients who completed a satisfaction survey (267 out of 540 patients, 49.4% response rate) indicated they were satisfied with their care, irrespective of the kind of consult (mean 10-point Likert score of 8.5). 88 of 205 primary care physicians surveyed (42.9%) returned at least one survey; VC and TC survey response rates and consulted departments were comparable (p = 0.13). More TCs than VCs requested transfer of patient care (p = 0.03), assistance with diagnosis (p = 0.04) or initiating treatment (p =0.04). Within 3 weeks of the consultation request, 72.1% of respondents reported receiving information from VCs, compared with 33.9% of the TCs (p < 0.001). Utility of information provided by consultants and satisfaction with consultations did not differ between VCs and TCs. Conclusions Referring physicians received information from consultants more quickly from VCs compared with TCs, but the value and application of information from both types of consultations were similar. VCs may decrease the need for face-to-face specialty encounters without a decrease in the patient’s perception of care. PMID:22769592
Women as Leaders of Higher Education Institutions: A British-German Comparison
ERIC Educational Resources Information Center
Read, Barbara; Kehm, Barbara M.
2016-01-01
Across the vast majority of countries women are a significant minority in senior academic positions, and as of 2013 only 17% of vice chancellors (VCs) of UK universities and 12% of German Universities were women. This paper discusses findings from a study consisting of interviews with eight female VCs of British and German higher education…
Picton, Anabela C P; Paximadis, Maria; Chaisson, Richard E; Martinson, Neil A; Tiemessen, Caroline T
2017-07-01
CXCR6 genetic variation was described for HIV-1-uninfected black (n=41) and Caucasian (n=40) South Africans. We also investigated the CXCR6 rs2234358 and rs2234355 single nucleotide polymorphisms in HIV-1 disease control in 124 HIV-1-infected drug-naïve black individuals [elite controllers (n=11), viraemic controllers (VCs, n=30), high viral load long-term nonprogressors (HVL LTNPs, n=11) and progressors (n=72)] compared to healthy controls (HCs; n=232). The rs2234358-T allele was underrepresented in VCs (40.0%) compared to HCs (59%, P=0.006), HVL LTNPs (72.7%, P=0.012) and progressors (59%, P=0.014). The rs2234358-TT genotype was underrepresented in VCs (7%) compared to progressors (32%; OR=6.57, P=0.006) and HCs (35%; OR=7.18, P=0.001, P bonferroni =0.034). The rs2234355-GA genotype was overrepresented in VCs (80%) compared to HCs (50.4%; OR=0.25, P=0.003) and progressors (29.17%; OR=0.10, P=3.8×10 -5 , P bonferroni =0.001). The combination of rs2234355-GA in the absence of rs2234358-TT was overrepresented in VCs (80%) compared to HCs (32.6%, OR=0.12, P=1×10 -6 , P bonferroni =3.4×10 -5 ) and to progressors (16.7%; OR=0.05, P<1×10 -8 , P bonferroni <1×10 -7 ). Copyright © 2017 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Breakwell, Glynis M.; Tytherleigh, Michelle Y.
2008-01-01
While not the only title used by UK university leaders, the term Vice Chancellor will be used throughout this paper to include the other titles used (including Rector, Provost, Principal and President). According to data obtained pre-1997, UK Vice Chancellors (VCs) were predominantly scientists, largely former professors, Pro-VCs or deputy…
Cai, Jing; Tyree, Melvin T
2010-07-01
The objective of this study was to quantify the relationship between vulnerability to cavitation and vessel diameter within a species. We measured vulnerability curves (VCs: percentage loss hydraulic conductivity versus tension) in aspen stems and measured vessel-size distributions. Measurements were done on seed-grown, 4-month-old aspen (Populus tremuloides Michx) grown in a greenhouse. VCs of stem segments were measured using a centrifuge technique and by a staining technique that allowed a VC to be constructed based on vessel diameter size-classes (D). Vessel-based VCs were also fitted to Weibull cumulative distribution functions (CDF), which provided best-fit values of Weibull CDF constants (c and b) and P(50) = the tension causing 50% loss of hydraulic conductivity. We show that P(50) = 6.166D(-0.3134) (R(2) = 0.995) and that b and 1/c are both linear functions of D with R(2) > 0.95. The results are discussed in terms of models of VCs based on vessel D size-classes and in terms of concepts such as the 'pit area hypothesis' and vessel pathway redundancy.
NASA Astrophysics Data System (ADS)
Longman, Peter J.; How, Thomas C.; Hudson, Craig; Clarkson, Geoffrey J. N.
2001-08-01
The Defence Evaluation Research Agency carried out an airborne demonstration and evaluation of a fast-jet Visually Coupled System (VCS) installed in ZD902, the Tornado Integrated Avionics Research Aircraft for the UK MOD. The installed VCS used a Head Steered Forward Looking Infra-Red (HSFLIR) sensor and a Head Tracking system to provide the pilot with an image of the outside world projected onto a Binocular Helmet Mounted Display. In addition to the sensor image, information such as aircraft altitude, attitude, and airspeed were also presented to the pilot through the HMD to eliminate the need to look inside the cockpit for critical flight data. The aim of the VIVIAN trial was to demonstrate by day and night the benefits of a fast-jet integrated HSFLIR and HMD as an aid to low level flight, navigation, target acquisition, take-off and landing. The outcome of this flight test program was very encouraging and, although testing has identified that improvements are necessary, in particular to HSFLIR image quality, Auto Gain Control performance, helmet fit and symbology design, test aircrew endorse the acceptability of a VCS.
Lima-Hernández, F J; Gómora-Arrati, P; García-Juárez, M; Blaustein, J D; Etgen, A M; Beyer, C; González-Flores, O
2014-07-01
The role of classical estrogen receptors (ERs) in priming female reproductive behavior has been studied previously; however, the participation of this receptor during activation of estrous behavior has not been extensively studied. The purpose of this work was to test the possibility that the facilitation of lordosis behavior in estrogen-primed rats by progesterone (P) and its 5α- and 5β-reduced metabolites, gonadotropin-releasing hormone (GnRH), leptin, prostaglandin E2 (PGE2) and vagino-cervical stimulation (VCS) involves interactions with classical ERs by using the selective ER modulator, tamoxifen. To further assess the role of ERs, we also explored the effects of the pure ER antagonist, ICI182780 (ICI), on estrous behavior induced by P and GnRH. Ovariectomized, estrogen-primed rats (5μg estradiol benzoate 40h earlier) were injected intraventricularly with the above-mentioned compounds, or they received VCS. All compounds and VCS effectively facilitated estrous behavior when tested at 60, 120 or 240min after infusion or application of VCS. Intraventricular infusion of tamoxifen (5μg), 30min before, significantly attenuated estrous behaviors induced in estradiol-primed rats by P, most of its 5α- and 5β-reduced metabolites, GnRH, and PGE2, but not by VCS. Although there was a trend for reduction, tamoxifen did not significantly decrease lordosis in females treated with 5β-pregnan-3,20-dione. ICI also inhibited lordosis behavior induced by P and GnRH at some testing intervals. These results suggest that activation of classical ERs participates in the triggering effects on estrous behavior induced by agents with different chemical structures that do not bind directly to ERs. Copyright © 2014 Elsevier Inc. All rights reserved.
Kendrick, K M; Lévy, F; Keverne, E B
1991-09-01
The importance of vaginocervical stimulation for the formation of the maternal bond between a ewe and its lambs was investigated by studying the ability of artificial mechanical vaginocervical stimulation to induce adoption of an alien lamb after the selective bond with the ewe's own lambs had been formed. Results showed that for both multiparous and primiparous ewes, 5 min of mechanical VCS (using a hand) was effective in inducing complete acceptance of an alien lamb (6-48 h old) between 6.5 and 7.5 h postpartum in the majority of animals (8/10 multiparous, 8/9 primiparous) without interfering with the bond between the ewe and its own lambs. In a second group of multiparous animals, 6 out of 7 animals were also induced to completely accept an alien lamb between 26.5 and 27.5 h postpartum. It was found that the most critical aspect of the VCS was pressure on, and stretching the neck of, the cervix. Results show that VCS is not only important for the stimulation of maternal behavior, but also for the formation of the selective maternal bond. The ability of VCS to trigger the formation of a new maternal bond extends for at least 27.5 h post-partum.
Assessing problem-solving skills in construction education with the virtual construction simulator
NASA Astrophysics Data System (ADS)
Castronovo, Fadi
The ability to solve complex problems is an essential skill that a construction and project manager must possess when entering the architectural, engineering, and construction industry. Such ability requires a mixture of problem-solving skills, ranging from lower to higher order thinking skills, composed of cognitive and metacognitive processes. These skills include the ability to develop and evaluate construction plans and manage the execution of such plans. However, in a typical construction program, introducing students to such complex problems can be a challenge, and most commonly the learner is presented with only part of a complex problem. To support this challenge, the traditional methodology of delivering design, engineering, and construction instruction has been going through a technological revolution, due to the rise of computer-based technology. For example, in construction classrooms, and other disciplines, simulations and educational games are being utilized to support the development of problem-solving skills. Previous engineering education research has illustrated the high potential that simulations and educational games have in engaging in lower and higher order thinking skills. Such research illustrated their capacity to support the development of problem-solving skills. This research presents evidence supporting the theory that educational simulation games can help with the learning and retention of transferable problem-solving skills, which are necessary to solve complex construction problems. The educational simulation game employed in this study is the Virtual Construction Simulator (VCS). The VCS is a game developed to provide students in an engaging learning activity that simulates the planning and managing phases of a construction project. Assessment of the third iteration of the VCS(3) game has shown pedagogical value in promoting students' motivation and a basic understanding of construction concepts. To further evaluate the benefits on problem-solving skills, a new version of the VCS(4) was developed, with new building modules and assessment framework. The design and development of the VCS4 leveraged research in educational psychology, multimedia learning, human-computer interaction, and Building Information Modeling. In this dissertation the researcher aimed to evaluate the pedagogical value of the VCS4 in fostering problem-solving skills. To answer the research questions, a crossover repeated measures quasi-experiment was designed to assess the educational gains that the VCS can provide to construction education. A group of 34 students, attending a fourth-year construction course at a university in the United States was chosen to participate in the experiment. The three learning modules of the VCS were used, which challenged the students to plan and manage the construction process of a wooden pavilion, the steel erection of a dormitory, and the concrete placement of the same dormitory. Based on the results the researcher was able to provide evidence supporting the hypothesis that the chosen sample of construction students were able to gain and retain problem-solving skills necessary to solve complex construction simulation problems, no matter what the sequence with which these modules were played. In conclusion, the presented results provide evidence supporting the theory that educational simulation games can help the learning and retention of transferable problem-solving skills, which are necessary to solve complex construction problems.
DTO-675: Voice Control of the Closed Circuit Television System
NASA Technical Reports Server (NTRS)
Salazar, George; Gaston, Darilyn M.; Haynes, Dena S.
1996-01-01
This report presents the results of the Detail Test Object (DTO)-675 "Voice Control of the Closed Circuit Television (CCTV)" system. The DTO is a follow-on flight of the Voice Command System (VCS) that flew as a secondary payload on STS-41. Several design changes were made to the VCS for the STS-78 mission. This report discusses those design changes, the data collected during the mission, recognition problems encountered, and findings.
Research on Seismic Wave Attenuation in Gas Hydrates Layer Using Vertical Cable Seismic Data
NASA Astrophysics Data System (ADS)
Wang, Xiangchun; Liang, Lunhang; Wu, Zhongliang
2018-06-01
Vertical cable seismic (VCS) data are the most suitable seismic data for estimating the quality factor Q values of layers under the sea bottom by now. Here the quality factor Q values are estimated using the high-precision logarithmic spectrum ratio method for VCS data. The estimated Q values are applied to identify the layers with gas hydrates and free gas. From the results it can be seen that the Q value in layer with gas hydrates becomes larger and the Q value in layer with free gas becomes smaller than layers without gas hydrates or free gas. Additionally, the estimated Q values are used for inverse Q filtering processing to compensate the attenuated seismic signal's high-frequency component. From the results it can be seen that the main frequency of seismic signal is improved and the frequency band is broadened, the resolution of the VCS data is improved effectively.
The role of perceived interactivity in virtual communities: building trust and increasing stickiness
NASA Astrophysics Data System (ADS)
Wang, Hongwei; Meng, Yuan; Wang, Wei
2013-03-01
Although previous research has explored factors affecting trust building in websites, little research has been analysed from the perceived interactivity perspective in virtual communities (VCs). A research model for verifying interactivity antecedents to trust and its impact on member stickiness behaviour is presented. Two social interactivity components and two system interactivity components are, respectively, theorised as process-based antecedents and institution-based antecedents to trust in the model. Data were collected from 310 members of VCs to test the model. The results show that connectedness and reciprocity are important antecedents to trust in members, while responsiveness and active control are important antecedents to trust in systems. The results also indicate that trust has significant influence on the members' duration and retention, which are two dimensions of member stickiness measured in this research. These findings have theoretical implications for online interaction-related literature and critical business implications for practitioners of VCs.
Generalized polarizabilities of the nucleon in baryon chiral perturbation theory
NASA Astrophysics Data System (ADS)
Lensky, Vadim; Pascalutsa, Vladimir; Vanderhaeghen, Marc
2017-02-01
The nucleon generalized polarizabilities (GPs), probed in virtual Compton scattering (VCS), describe the spatial distribution of the polarization density in a nucleon. They are accessed experimentally via the process of electron-proton bremsstrahlung (ep→ epγ ) at electron-beam facilities, such as MIT-Bates, CEBAF (Jefferson Lab), and MAMI (Mainz). We present the calculation of the nucleon GPs and VCS observables at next-to-leading order in baryon chiral perturbation theory (Bχ PT), and confront the results with the empirical information. At this order our results are predictions, in the sense that all the parameters are well known from elsewhere. Within the relatively large uncertainties of our calculation we find good agreement with the experimental observations of VCS and the empirical extractions of the GPs. We find large discrepancies with previous chiral calculations - all done in heavy-baryon χ PT (HBχ PT) - and discuss the differences between Bχ PT and HBχ PT responsible for these discrepancies.
5′ to 3′ mRNA Decay Contributes to the Regulation of Arabidopsis Seed Germination by Dormancy1
Basbouss-Serhal, Isabelle; Pateyron, Stéphanie; Cochet, Françoise
2017-01-01
The regulation of plant gene expression, necessary for development and adaptive responses, relies not only on RNA transcription but also on messenger RNA (mRNA) fate. To understand whether seed germination relies on the degradation of specific subsets of mRNA, we investigated whether the 5′ to 3′ RNA decay machinery participated in the regulation of this process. Arabidopsis (Arabidopsis thaliana) seeds of exoribonuclease4 (xrn4) and varicose (vcs) mutants displayed distinct dormancy phenotypes. Transcriptome analysis of xrn4-5 and vcs-8 mutant seeds allowed us to identify genes that are likely to play a role in the control of germination. Study of 5′ untranslated region features of these transcripts revealed that specific motifs, secondary energy, and GC content could play a role in their degradation by XRN4 and VCS, and Gene Ontology clustering revealed novel actors of seed dormancy and germination. Several specific transcripts identified as being putative targets of XRN4 and VCS in seeds (PECTIN LYASE-LIKE, ASPARTYL PROTEASE, DWD-HYPERSENSITIVE-TO-ABA3, and YELLOW STRIPE-LIKE5) were further studied by reverse genetics, and their functional roles in the germination process were confirmed by mutant analysis. These findings suggest that completion of germination and its regulation by dormancy also depend on the degradation of specific subsets of mRNA. PMID:28126845
Feng, Shanshan; Shi, Leiyu; Zeng, Jiazhi; Chen, Wen; Ling, Li
2017-01-01
Objectives In order to improve the quality of services at village clinics (VCs), which are important primary care service providers in rural China, the Chinese government has encouraged the township hospitals to own and manage VCs. There are currently three models of ownership and management of VCs: township hospital-owned and -managed (HVC), village committee-owned and -managed (VVC), and private-owned and -managed (PVC). This study aims to examine the association between these ownership models of VCs and patients' primary care experiences. Methods Villagers were selected by multistage stratified sampling and their experiences with primary care were measured using the Primary Care Assessment Tool—Adult Edition (PCAT-AS). Data were collected through face-to-face interviews and the questionnaires administered by investigators in the cross-sectional study from February to April 2015. The PCAT scores were compared among the three models by covariance analysis, and multiple linear regression was used to analyze factors associated with the PCAT total scores. Results A total of 1491 questionnaires were collected. After controlling for covariates, HVCs reported the highest PCAT scores and satisfaction rate. In terms of the domains, HVC reported the highest scores in the coordination and comprehensiveness domains, while PVC had the highest scores in the first contact-accessibility domain. Multivariate linear regression showed that HVC, married participants, aged 60 and older, satisfied with the services, receiving six or more visits, and those with medical expenditures over 20% of their total family expenditures, were also positively associated with better primary care quality. Conclusions This study demonstrates that villagers receiving medical care at HVCs perceived better primary care than those at PVCs and VVCs. In order to improve the quality of primary care at VCs, it is necessary to increase government subsidies for public service packages, tighten the township hospital's supervision of PVCs and VVCs, and develop performance-based incentive plans to motivate improvements in the accessibility of HVCs. PMID:28056038
Birth, Matthias; Markert, Uwe; Strik, Martin; Wohlschläger, Charlotte; Brugmans, Frederik; Gerberding, Jürgen; Bruch, Hans P
2002-01-15
In orthotopic liver transplantation the incidence of biliary complications is up to 49%. In view of the relative frequency of such complications despite seemingly good preconditions, method-related disadvantages of conventional suture must also be considered as a possible cause. These include perforating needle injury of the choledochal wall with at least temporary exposure of suture material in the lumen, suboptimal approximation of the mucosa, and an additional decrease in blood flow in the choledochal stumps as a result of suture-related tissue strangulation. Hence the search for alternative anastomosis techniques. To evaluate the surgical suitability of extramucosal titanium clips (Vascular Closure Staples; VCS) in comparison with conventional manual suture, a study was performed in 36 pigs, which were randomly assigned to 4 groups, each containing 9 animals. Choledochal excision was performed in 18 pigs and transection in the other 18 pigs; end-to-end anastomosis was then carried out, using a VCS stapler in half of the animals in each of these two groups and conventional manual suture in the other half. Pre- and postanastomotic blood flow was measured during the surgery with the aid of a laser Doppler flow meter. The long-term behavior of the closure techniques was ascertained by regular laboratory checks over the ensuing 6-month observation period, after which the pigs were killed so that the specimens could be harvested. Using medium-sized VCS clips, we were able to create a tension-free, everted biliary anastomosis with exact mucosal approximation and no narrowing of the lumen, and without any technical problems during the performance of the procedure. Measurements with the laser Doppler flow meter showed well-preserved anastomotic blood flow after clip reconstruction, with significantly higher perfusion values than after manual suture. The postoperative courses of the investigated laboratory parameters did not reveal any significant differences between the two methods. In contrast, histomorphometric evaluation showed wall thickness and thus fibrosis in the anastomosis region to be less in the clip group than in the suture group (median: 510 microm versus 660 microm, P<0.001). In the pigs in which clip anastomosis was used, there were no detectable anastomotic stenoses; in the pigs in which conventional suture was used, however, ultrasonography revealed five anastomoses with varying degrees of narrowing. Extramucosal VCS clip anastomosis not only offers potential advantages with respect to nonpenetrating and optimal mucosal contact, investigations in animals also show it to be superior to conventional manual suture as regards anastomotic blood flow and medium-term fibrosis formation. We believe that our data and the available literature warrant a clinical evaluation of this technique in appropriate studies.
Automatic speech recognition research at NASA-Ames Research Center
NASA Technical Reports Server (NTRS)
Coler, Clayton R.; Plummer, Robert P.; Huff, Edward M.; Hitchcock, Myron H.
1977-01-01
A trainable acoustic pattern recognizer manufactured by Scope Electronics is presented. The voice command system VCS encodes speech by sampling 16 bandpass filters with center frequencies in the range from 200 to 5000 Hz. Variations in speaking rate are compensated for by a compression algorithm that subdivides each utterance into eight subintervals in such a way that the amount of spectral change within each subinterval is the same. The recorded filter values within each subinterval are then reduced to a 15-bit representation, giving a 120-bit encoding for each utterance. The VCS incorporates a simple recognition algorithm that utilizes five training samples of each word in a vocabulary of up to 24 words. The recognition rate of approximately 85 percent correct for untrained speakers and 94 percent correct for trained speakers was not considered adequate for flight systems use. Therefore, the built-in recognition algorithm was disabled, and the VCS was modified to transmit 120-bit encodings to an external computer for recognition.
Xie, Zongping; Liu, Xin; Jia, Weitao; Zhang, Changqing; Huang, Wenhai; Wang, Jianqiang
2009-10-15
The effectiveness of a degradable and bioactive borate glass has been compared with the clinically used calcium sulfate in the treatment of osteomyelitis of rabbits, as a carrier for vancomycin. The bone infections were induced in the tibias of 65 rabbits by injecting methicillin-resistant Staphylococcus aureus (MRSA). After 3 weeks, these rabbits were distributed into 4 groups and treated by debridement. Pure borate glass (BG), vancomycin-loaded calcium sulfate (VCS) and vancomycin-loaded borate glass (VBG) were implanted into the infection sites of groups 2 to 4 respectively. After 8 weeks, the effectiveness of treatment was assessed radiographically, bacteriologically, and histopathologically. The results showed that the negative rates of MRSA examination for rabbits were 36.36%, 18.18%, 73.33% and 81.25% respectively for groups 1 to 4. Significant differences were observed radiographically, bacteriologically, and histopathologically between groups 1 and 4, groups 2 and 3, and between groups 2 and 4. The best result of treatment was observed in group 4. Radiographically, VBG was found to be mostly reabsorbed and replaced by lots of new bones, whereas, VCS was completely reabsorbed and replaced by modest new bones. Histopathologically, there were lots of newly formed bones around VBG without any foreign body response, and only modest new bones around VCS with obvious foreign body response. VBG proved to have excellent biocompatibility and to be very effective in eradicating osteomyelitis and simultaneously stimulating bone regeneration, avoiding the disadvantages of VCS.
Kalra, Varun; Ahmad, Sohaib; Shrivastava, Vikas; Mittal, Garima
2016-05-01
A single diagnostic test for acute undifferentiated febrile illnesses (AUFI) is elusive. This pilot study was undertaken on the premise that leucocytes, being the main cells of defence, undergo quantitative, structural and functional changes in AUFI. We evaluated the potential of volume, conductivity and scatter (VCS) parameters of leucocytes, generated with the haemogram report by the Coulter auto-analyzer, in differentiating the common etiologies of AUFI. The haematological and VCS data obtained from 800 controls and 200 cases of AUFI (50 cases each of acute malaria, dengue, scrub typhus and enteric fever) were retrieved for analysis. The cases and controls differed significantly with respect to relative numbers and the VCS parameters of neutrophils, lymphocytes and monocytes (p<0.05). The neutrophil and lymphocyte were significantly voluminous in acute malaria and scrub typhus as compared to dengue and enteric fevers (p<0.05). Enteric fever significantly enhanced the conductivity of neutrophils as compared to other subgroups while lymphocyte conductivity significantly differed from dengue and scrub typhus. Lymphocyte and neutrophil scatter values in malaria and scrub typhus were comparable but differed significantly from that in enteric fever. Etiology-specific changes occur in leucocytes, both in numbers and their VCS properties which can be identified without additional cost. © The Author 2016. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Phenotypically silent Cre recombination within the postnatal ventricular conduction system.
Bhattacharyya, Samadrita; Bhakta, Minoti; Munshi, Nikhil Vilas
2017-01-01
The cardiac conduction system (CCS) is composed of specialized cardiomyocytes that initiate and maintain cardiac rhythm. Any perturbation to the normal sequence of electrical events within the heart can result in cardiac arrhythmias. To understand how cardiac rhythm is established at the molecular level, several genetically modified mouse lines expressing Cre recombinase within specific CCS compartments have been created. In general, Cre driver lines have been generated either by homologous recombination of Cre into an endogenous locus or Cre expression driven by a randomly inserted transgene. However, haploinsufficiency of the endogenous gene compromises the former approach, while position effects negatively impact the latter. To address these limitations, we generated a Cre driver line for the ventricular conduction system (VCS) that preserves endogenous gene expression by targeting the Contactin2 (Cntn2) 3' untranslated region (3'UTR). Here we show that Cntn23'UTR-IRES-Cre-EGFP/+ mice recombine floxed alleles within the VCS and that Cre expression faithfully recapitulates the spatial distribution of Cntn2 within the heart. We further demonstrate that Cre expression initiates after birth with preservation of native Cntn2 protein. Finally, we show that Cntn23'UTR-IRES-Cre-EGFP/+ mice maintain normal cardiac mechanical and electrical function. Taken together, our results establish a novel VCS-specific Cre driver line without the adverse consequences of haploinsufficiency or position effects. We expect that our new mouse line will add to the accumulating toolkit of CCS-specific mouse reagents and aid characterization of the cell-autonomous molecular circuitry that drives VCS maintenance and function.
UAV visual signature suppression via adaptive materials
NASA Astrophysics Data System (ADS)
Barrett, Ron; Melkert, Joris
2005-05-01
Visual signature suppression (VSS) methods for several classes of aircraft from WWII on are examined and historically summarized. This study shows that for some classes of uninhabited aerial vehicles (UAVs), primary mission threats do not stem from infrared or radar signatures, but from the amount that an aircraft visually stands out against the sky. The paper shows that such visual mismatch can often jeopardize mission success and/or induce the destruction of the entire aircraft. A psycho-physioptical study was conducted to establish the definition and benchmarks of a Visual Cross Section (VCS) for airborne objects. This study was centered on combining the effects of size, shape, color and luminosity or effective illumance (EI) of a given aircraft to arrive at a VCS. A series of tests were conducted with a 6.6ft (2m) UAV which was fitted with optically adaptive electroluminescent sheets at altitudes of up to 1000 ft (300m). It was shown that with proper tailoring of the color and luminosity, the VCS of the aircraft dropped from more than 4,200cm2 to less than 1.8cm2 at 100m (the observed lower limit of the 20-20 human eye in this study). In laypersons terms this indicated that the UAV essentially "disappeared". This study concludes with an assessment of the weight and volume impact of such a Visual Suppression System (VSS) on the UAV, showing that VCS levels on this class UAV can be suppressed to below 1.8cm2 for aircraft gross weight penalties of only 9.8%.
Virtual Compton Scattering and the Generalized Polarizabilities of the Proton
NASA Astrophysics Data System (ADS)
Hyde-Wright, Charles E.
2002-10-01
The Virtual Compton Scattering (VCS) process: e p arrow e p γ is sensitive to the Electromagnetic Polarizabilities of the proton. As a function of the wavelength of the virtual photon, it is possible to map out the spatial variation of the polarization response. The Low Energy Theorem (P. Guichon et al.,Nucl.Phys.A591:606-638,1995) and the Dispersion Relation formalism (B. Pasquini et al., Eur.Phys.J.A11:185-208,2001), permit the extraction of the electric and magnetic polarizabilities from VCS data up to the two pion production threshold. At Jefferson Lab, we have measured the electric and magnetic polarization response at Q^2 = 1 and 1.7 GeV^2. These complement earlier measurements at Q^2 = 0.33 (J. Roche, et al., Phys.Rev.Lett.85:708,2000) and 0.0 GeV^2 (V. Olmos de Leon, et al., Eur.Phys.J.A10:207-215,2001, B.E. MacGibbon, et al., Phys.Rev.C52:2097-2109,1995). The electric polarization and magnetic responses are very different as a function of distance scale. The electric polarizability falls with Q^2 in accord with the electric form factor of the proton: G_E(Q^2). However, for the magnetic polarizability the data illustrate the strong cancellation of para- and dia-magnetism at all distance scales within the proton.
Observation of the production of a W boson in association with a single charm quark.
Aaltonen, T; Amerio, S; Amidei, D; Anastassov, A; Annovi, A; Antos, J; Apollinari, G; Appel, J A; Arisawa, T; Artikov, A; Asaadi, J; Ashmanskas, W; Auerbach, B; Aurisano, A; Azfar, F; Badgett, W; Bae, T; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Barria, P; Bartos, P; Bauce, M; Bedeschi, F; Behari, S; Bellettini, G; Bellinger, J; Benjamin, D; Beretvas, A; Bhatti, A; Bland, K R; Blumenfeld, B; Bocci, A; Bodek, A; Bortoletto, D; Boudreau, J; Boveia, A; Brigliadori, L; Bromberg, C; Brucken, E; Budagov, J; Burkett, K; Busetto, G; Bussey, P; Butti, P; Buzatu, A; Calamba, A; Camarda, S; Campanelli, M; Canelli, F; Carls, B; Carlsmith, D; Carosi, R; Carrillo, S; Casal, B; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavaliere, V; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Cho, K; Chou, J P; Chokheli, D; Clark, A; Clarke, C; Convery, M E; Conway, J; Corbo, M; Cordelli, M; Cox, C A; Cox, D J; Cremonesi, M; Cuevas, J; Culbertson, R; d'Ascenzo, N; Datta, M; Demortier, L; Deninno, M; Devoto, F; d'Errico, M; Di Canto, A; Di Ruzza, B; Dittmann, J R; D'Onofrio, M; Donati, S; Dorigo, M; Driutti, A; Ebina, K; Edgar, R; Elagin, A; Erbacher, R; Errede, S; Esham, B; Eusebi, R; Farrington, S; Fernández Ramos, J P; Field, R; Flanagan, G; Forrest, R; Franklin, M; Freeman, J C; Funakoshi, Y; Garfinkel, A F; Garosi, P; Gerberich, H; Gerchtein, E; Giagu, S; Giakoumopoulou, V; Gibson, K; Ginsburg, C M; Giokaris, N; Giromini, P; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldin, D; Goldschmidt, N; Golossanov, A; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González López, O; Gorelov, I; Goshaw, A T; Goulianos, K; Gramellini, E; Grinstein, S; Grosso-Pilcher, C; Group, R C; Guimaraes da Costa, J; Hahn, S R; Han, J Y; Happacher, F; Hara, K; Hare, M; Harr, R F; Harrington-Taber, T; Hatakeyama, K; Hays, C; Heinrich, J; Herndon, M; Hocker, A; Hopkins, W; Hou, S; Hughes, R E; Hurwitz, M; Husemann, U; Huston, J; Introzzi, G; Iori, M; Ivanov, A; James, E; Jang, D; Jayatilaka, B; Jeon, E J; Jindariani, S; Jones, M; Joo, K K; Jun, S Y; Junk, T R; Kambeitz, M; Kamon, T; Karchin, P E; Kasmi, A; Kato, Y; Ketchum, W; Keung, J; Kilminster, B; Kim, D H; Kim, H S; Kim, J E; Kim, M J; Kim, S B; Kim, S H; Kim, Y K; Kim, Y J; Kimura, N; Kirby, M; Klimenko, S; Knoepfel, K; Kondo, K; Kong, D J; Konigsberg, J; Kotwal, A V; Kreps, M; Kroll, J; Krop, D; Kruse, M; Kuhr, T; Kurata, M; Kwang, S; Laasanen, A T; Lammel, S; Lancaster, M; Lannon, K; Latino, G; Lee, H S; Lee, J S; Leone, S; Lewis, J D; Limosani, A; Lipeles, E; Liu, H; Liu, Q; Liu, T; Lockwitz, S; Loginov, A; Lucchesi, D; Lueck, J; Lujan, P; Lukens, P; Lungu, G; Lys, J; Lysak, R; Madrak, R; Maestro, P; Malik, S; Manca, G; Manousakis-Katsikakis, A; Margaroli, F; Martínez, M; Matera, K; Mattson, M E; Mazzacane, A; Mazzanti, P; McNulty, R; Mehta, A; Mehtala, P; Mesropian, C; Miao, T; Mietlicki, D; Mitra, A; Miyake, H; Moed, S; Moggi, N; Moon, C S; Moore, R; Morello, M J; Mukherjee, A; Muller, Th; Murat, P; Mussini, M; Nachtman, J; Nagai, Y; Naganoma, J; Nakano, I; Napier, A; Nett, J; Neu, C; Nigmanov, T; Nodulman, L; Noh, S Y; Norniella, O; Oakes, L; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Orava, R; Ortolan, L; Pagliarone, C; Palencia, E; Palni, P; Papadimitriou, V; Parker, W; Pauletta, G; Paulini, M; Paus, C; Phillips, T J; Piacentino, G; Pianori, E; Pilot, J; Pitts, K; Plager, C; Pondrom, L; Poprocki, S; Potamianos, K; Prokoshin, F; Pranko, A; Ptohos, F; Punzi, G; Ranjan, N; Redondo Fernández, I; Renton, P; Rescigno, M; Riddick, T; Rimondi, F; Ristori, L; Robson, A; Rodriguez, T; Rolli, S; Ronzani, M; Roser, R; Rosner, J L; Ruffini, F; Ruiz, A; Russ, J; Rusu, V; Safonov, A; Sakumoto, W K; Sakurai, Y; Santi, L; Sato, K; Saveliev, V; Savoy-Navarro, A; Schlabach, P; Schmidt, E E; Schwarz, T; Scodellaro, L; Seidel, S; Seiya, Y; Semenov, A; Sforza, F; Shalhout, S Z; Shears, T; Shepard, P F; Shimojima, M; Shochet, M; Shreyber-Tecker, I; Simonenko, A; Sinervo, P; Sliwa, K; Smith, J R; Snider, F D; Sorin, V; Song, H; Stancari, M; St Denis, R; Stelzer, B; Stelzer-Chilton, O; Stentz, D; Strologas, J; Sudo, Y; Sukhanov, A; Suslov, I; Takemasa, K; Takeuchi, Y; Tang, J; Tecchio, M; Teng, P K; Thom, J; Thomson, E; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Totaro, P; Trovato, M; Ukegawa, F; Uozumi, S; Vázquez, F; Velev, G; Vellidis, C; Vernieri, C; Vidal, M; Vilar, R; Vizán, J; Vogel, M; Volpi, G; Wagner, P; Wallny, R; Wang, S M; Warburton, A; Waters, D; Wester, W C; Whiteson, D; Wicklund, A B; Wilbur, S; Williams, H H; Wilson, J S; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, H; Wright, T; Wu, X; Wu, Z; Yamamoto, K; Yamato, D; Yang, T; Yang, U K; Yang, Y C; Yao, W-M; Yeh, G P; Yi, K; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Zanetti, A M; Zeng, Y; Zhou, C; Zucchelli, S
2013-02-15
The first observation of the production of a W boson with a single charm quark (c) jet in pp[over ¯] collisions at √s=1.96 TeV is reported. The analysis uses data corresponding to 4.3 fb(-1), recorded with the CDF II detector at the Fermilab Tevatron. Charm quark candidates are selected through the identification of an electron or muon from charm-hadron semileptonic decay within a hadronic jet, and a Wc signal is observed with a significance of 5.7 standard deviations. The production cross section σ(Wc)(p(Tc)>20 GeV/c,|η(c)|<1.5)×B(W→ℓν) is measured to be 13.6(-3.1)(+3.4) pb and is in agreement with theoretical expectations. From this result the magnitude of the quark-mixing matrix element V(cs) is derived, |V(cs)|=1.08±0.16 along with a lower limit of |V(cs)|>0.71 at the 95% confidence level, assuming that the Wc production through c to s quark coupling is dominant.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laveissiere, Geraud
In hadronic physics, the nucleon structure and the quarks confinement are still topical issues. The neutral pion electroproduction and virtual Compton scattering (VCS) reactions allow us to access new observables that describe this structure. This work is focused on the VCS experiment performed at Jefferson Lab in 1998.
[Injectable borate glass/chitosan composite as drug carrier for treatment of chronic osteomyelitis].
Zhao, Cunju; Wang, Xinfu; Zhang, Changqing; Cui, Xu; Jia, Weitao; Huang, Wenchan
2012-06-01
To evaluate the characterization, biocompatibility in vitro and in vivo, and antimicrobial activity of an injectable vancomycin-loaded borate glass/chitosan composite (VBC) so as to lay the foundation for its further clinical application. The solid phase of VBC was constituted by borate glass and vancomycin, liquid phase was a mixture of chitosan, citric acid, and glucose with the proportion of 1 : 10 : 20. Solid phase and liquid phase was mixed with the ratio of 2 : 1. Vancomycin-loaded calcium sulfate (VCS) was produced by the same method using calcium sulfate instead of borate glass and saline instead of chitosan, as control. High performance liquid chromatography was applied to detect the release rate of antibiotics from VBC and VCS, and minimum inhibitory concentration (MIC) was tested by using an antibiotic tube dilution method. The structure of the VBC and VCS specimens before and 2, 4, 8, 16, and 40 days after immersion in D-Hank's was examined by scanning electron microscopy, and the phase composition of VBC was analysed by X-ray diffraction after soaked for 40 days. Thirty-three healthy adult New Zealand white rabbits (weighing, 2.25-3.10 kg; male or female) were used to establish the osteomyelitis models according to Norden method. After 4 weeks, the models of osteomyelitis were successfully established in 28 rabbits, and they were randomly divided into 4 groups (groups A, B, C, and D). In group A (n=8), simple debridement was performed; in groups B and C (n=8), defect was treated by injecting VCS or VBC after debridement; and in group D (n=4), no treatment was given. The effectiveness of treatment was assessed using radiological and histological techniques after 2 months. The releases of vancomycin from VBC lasted for 30 days; the release rate of vancomycin reached 75% at the first 8 days, then could reached more than 90%. The releases of vancomycin from VCS lasted only for 16 days. The MIC of VBC and VCS were both 2 microg/mL. The VCS had a smooth glass crystal surface before immersion, however, it was almost degradated after 4 days. The fairly smooth surface of the VBC pellet became more porous and rougher with time, X-ray diffraction analysis of VBC soaked for 40 days indicated that the borate glass had gradually converted to hydroxyapatite. After 2 months, the best result of treatment was observed in group C, osteomyelitis symptoms disappeared. The X-ray scores of groups A, B, C, and D were 3.50 +/- 0.63, 2.29 +/- 0.39, 2.00 +/- 0.41, and 4.25 +/- 0.64, respectively; Smeltzer scores were 6.00 +/- 0.89, 4.00 +/- 0.82, 3.57 +/- 0.98, and 7.25 +/- 0.50, respectively. The scores were significantly higher in group D than in groups A, B, and C (P < 0.05), and in group A than in groups B and C (P < 0.05). The scores were higher in group B than in group C, but no significant difference was found (P > 0.05). The VBC is effective in treating chronic osteomyelitis of rabbit by providing a sustained release of vancomycin, in addition to stimulating bone regeneration, so it may be a promising biomaterial for treating chronic osteomyelitis.
Second Epoch VLBA Calibrator Survey Observations - VCS-II
NASA Technical Reports Server (NTRS)
Gordon, David; Jacobs, Christopher; Beasley, Anthony; Peck, Alison; Gaume, Ralph; Charlot, Patrick; Fey, Alan; Ma, Chopo; Titov, Oleg; Boboltz, David
2016-01-01
Six very successful VLBA calibrator survey campaigns were run between 1994 and 2007 to build up a large list of compact radio sources with positions precise enough for use as VLBI phase reference calibrators. We report on the results of a second epoch VLBA Calibrator Survey campaign (VCS-II) in which 2400 VCS sources were re-observed at X and S bands in order to improve the upcoming third realization of the International Celestial Reference Frame (ICRF3) as well as to improve their usefulness as VLBI phase reference calibrators. In this survey, some 2062 previously detected sources and 324 previously undetected sources were detected and revised positions are presented. Average position uncertainties for the reobserved sources were reduced from 1.14 and 1.98 mas to 0.24 and 0.41 mas in RA and Declination, respectively, or by nearly a factor of 5. Minimum detected flux values were approximately 15 and 28 mJy in X and S bands, respectively, and median total fluxes are approximately 230 and 280 mJy. The vast majority of these sources are flat-spectrum sources, with approximately 82% having spectral indices greater than -0.5.
Second Epoch VLBA Calibrator Survey Observations: VCS-II
NASA Astrophysics Data System (ADS)
Gordon, David; Jacobs, Christopher; Beasley, Anthony; Peck, Alison; Gaume, Ralph; Charlot, Patrick; Fey, Alan; Ma, Chopo; Titov, Oleg; Boboltz, David
2016-06-01
Six very successful Very Long Baseline Array (VLBA) calibrator survey campaigns were run between 1994 and 2007 to build up a large list of compact radio sources with positions precise enough for use as very long baseline interferometry (VLBI) phase reference calibrators. We report on the results of a second epoch VLBA Calibrator Survey campaign (VCS-II) in which 2400 VCS sources were re-observed in the X and S bands in order to improve the upcoming third realization of the International Celestial Reference Frame (ICRF3) as well as to improve their usefulness as VLBI phase reference calibrators. In this survey, some 2062 previously detected sources and 324 previously undetected sources were detected and revised positions are presented. Average position uncertainties for the re-observed sources were reduced from 1.14 and 1.98 mas to 0.24 and 0.41 mas in R.A. and decl., respectively, or by nearly a factor of 5. Minimum detected flux values were approximately 15 and 28 mJy in the X and S bands, respectively, and median total fluxes are approximately 230 and 280 mJy. The vast majority of these sources are flat-spectrum sources, with ˜82% having spectral indices greater than -0.5.
Experimental performance study of a proposed desiccant based air conditioning system.
Bassuoni, M M
2014-01-01
An experimental investigation on the performance of a proposed hybrid desiccant based air conditioning system referred as HDBAC is introduced in this paper. HDBAC is mainly consisted of a liquid desiccant dehumidification unit integrated with a vapor compression system (VCS). The VCS unit has a cooling capacity of 5.27 kW and uses 134a as refrigerant. Calcium chloride (CaCl2) solution is used as the working desiccant material. HDBAC system is used to serve low sensible heat factor applications. The effect of different parameters such as, process air flow rate, desiccant solution flow rate, evaporator box and condenser box solution temperatures, strong solution concentration and regeneration temperature on the performance of the system is studied. The performance of the system is evaluated using some parameters such as: the coefficient of performance (COPa), specific moisture removal and energy saving percentage. A remarkable increase of about 54% in the coefficient of performance of the proposed system over VCS with reheat is achieved. A maximum overall energy saving of about 46% is observed which emphasizes the use of the proposed system as an energy efficient air conditioning system.
Experimental performance study of a proposed desiccant based air conditioning system
Bassuoni, M.M.
2013-01-01
An experimental investigation on the performance of a proposed hybrid desiccant based air conditioning system referred as HDBAC is introduced in this paper. HDBAC is mainly consisted of a liquid desiccant dehumidification unit integrated with a vapor compression system (VCS). The VCS unit has a cooling capacity of 5.27 kW and uses 134a as refrigerant. Calcium chloride (CaCl2) solution is used as the working desiccant material. HDBAC system is used to serve low sensible heat factor applications. The effect of different parameters such as, process air flow rate, desiccant solution flow rate, evaporator box and condenser box solution temperatures, strong solution concentration and regeneration temperature on the performance of the system is studied. The performance of the system is evaluated using some parameters such as: the coefficient of performance (COPa), specific moisture removal and energy saving percentage. A remarkable increase of about 54% in the coefficient of performance of the proposed system over VCS with reheat is achieved. A maximum overall energy saving of about 46% is observed which emphasizes the use of the proposed system as an energy efficient air conditioning system. PMID:25685475
NASA Astrophysics Data System (ADS)
Pan, Feng; Cao, Yu-Fang
1992-02-01
Vector coherent state (VCS) theory is applied to the group chain SOn+2⊇SOn×SO2. Matrix elements of SOn+2 generators in the SOn+2⊇SOn×SO2 basis are derived. A new formula for the evaluation of some isoscalar factors for SOn+2⊇SOn×SO2 with branching multiplicity is derived in the VCS framework. As a simple example, a new expression of some isoscalar factors for SO5⊇SO3×SO2, which involves only 6j coefficients and K-normalization factors, are obtained by using this formula.
Λ_{c}→Λl^{+}ν_{l} Form Factors and Decay Rates from Lattice QCD with Physical Quark Masses.
Meinel, Stefan
2017-02-24
The first lattice QCD calculation of the form factors governing Λ_{c}→Λℓ^{+}ν_{ℓ} decays is reported. The calculation was performed with two different lattice spacings and includes one ensemble with a pion mass of 139(2) MeV. The resulting predictions for the Λ_{c}→Λe^{+}ν_{e} and Λ_{c}→Λμ^{+}ν_{μ} decay rates divided by |V_{cs}|^{2} are 0.2007(71)(74) and 0.1945(69)(72) ps^{-1}, respectively, where the two uncertainties are statistical and systematic. Taking the Cabibbo-Kobayashi-Maskawa (CKM) matrix element |V_{cs}| from a global fit and the Λ_{c} lifetime from experiments, this translates to branching fractions of B(Λ_{c}→Λe^{+}ν_{e})=0.0380(19)_{LQCD}(11)_{τ_{Λ_{c}}} and B(Λ_{c}→Λμ^{+}ν_{μ})=0.0369(19)_{LQCD}(11)_{τ_{Λ_{c}}}. These results are consistent with, and two times more precise than, the measurements performed recently by the BESIII Collaboration. Using instead the measured branching fractions together with the lattice calculation to determine the CKM matrix element gives |V_{cs}|=0.949(24)_{LQCD}(14)_{τ_{Λ_{c}}}(49)_{B}.
NASA Astrophysics Data System (ADS)
Li, Chang; Wang, Qing; Shi, Wenzhong; Zhao, Sisi
2018-05-01
The accuracy of earthwork calculations that compute terrain volume is critical to digital terrain analysis (DTA). The uncertainties in volume calculations (VCs) based on a DEM are primarily related to three factors: 1) model error (ME), which is caused by an adopted algorithm for a VC model, 2) discrete error (DE), which is usually caused by DEM resolution and terrain complexity, and 3) propagation error (PE), which is caused by the variables' error. Based on these factors, the uncertainty modelling and analysis of VCs based on a regular grid DEM are investigated in this paper. Especially, how to quantify the uncertainty of VCs is proposed by a confidence interval based on truncation error (TE). In the experiments, the trapezoidal double rule (TDR) and Simpson's double rule (SDR) were used to calculate volume, where the TE is the major ME, and six simulated regular grid DEMs with different terrain complexity and resolution (i.e. DE) were generated by a Gauss synthetic surface to easily obtain the theoretical true value and eliminate the interference of data errors. For PE, Monte-Carlo simulation techniques and spatial autocorrelation were used to represent DEM uncertainty. This study can enrich uncertainty modelling and analysis-related theories of geographic information science.
Enhanced FCGR2A and FCGR3A signaling by HIV viremic controller IgG
Alvarez, Raymond A.; Maestre, Ana M.; Durham, Natasha D.; Barria, Maria Ines; Ishii-Watabe, Akiko; Tada, Minoru; Hotta, Mathew T.; Rodriguez-Caprio, Gabriela; Fierer, Daniel S.; Fernandez-Sesma, Ana; Simon, Viviana; Chen, Benjamin K.
2017-01-01
HIV-1 viremic controllers (VC) spontaneously control infection without antiretroviral treatment. Several studies indicate that IgG Abs from VCs induce enhanced responses from immune effector cells. Since signaling through Fc-γ receptors (FCGRs) modulate these Ab-driven responses, here we examine if enhanced FCGR activation is a common feature of IgG from VCs. Using an infected cell–based system, we observed that VC IgG stimulated greater FCGR2A and FCGR3A activation as compared with noncontrollers, independent of the magnitude of HIV-specific Ab binding or virus neutralization activities. Multivariate regression analysis showed that enhanced FCGR signaling was a significant predictor of VC status as compared with chronically infected patients (CIP) on highly active antiretroviral therapy (HAART). Unsupervised hierarchical clustering of patient IgG functions primarily grouped VC IgG profiles by enhanced FCGR2A, FCGR3A, or dual signaling activity. Our findings demonstrate that enhanced FCGR signaling is a common and significant predictive feature of VC IgG, with VCs displaying a distinct spectrum of FCGR activation profiles. Thus, profiling FCGR activation may provide a useful method for screening and distinguishing protective anti-HIV IgG responses in HIV-infected patients and in monitoring HIV vaccination regimens. PMID:28239647
NASA Astrophysics Data System (ADS)
Smeltzer, C. D.; Wang, Y.; Zhao, C.; Boersma, F.
2009-12-01
Polar orbiting satellite retrievals of tropospheric nitrogen dioxide (NO2) columns are important to a variety of scientific applications. These NO2 retrievals rely on a priori profiles from chemical transport models and radiative transfer models to derive the vertical columns (VCs) from slant columns measurements. In this work, we compare the retrieval results using a priori profiles from a global model (TM4) and a higher resolution regional model (REAM) at the OMI overpass hour of 1330 local time, implementing the Dutch OMI NO2 (DOMINO) retrieval. We also compare the retrieval results using a priori profiles from REAM model simulations with and without lightning NOx (NO + NO2) production. A priori model resolution and lightning NOx production are both found to have large impact on satellite retrievals by altering the satellite sensitivity to a particular observation by shifting the NO2 vertical distribution interpreted by the radiation model. The retrieved tropospheric NO2 VCs may increase by 25-100% in urban regions and be reduced by 50% in rural regions if the a priori profiles from REAM simulations are used during the retrievals instead of the profiles from TM4 simulations. The a priori profiles with lightning NOx may result in a 25-50% reduction of the retrieved tropospheric NO2 VCs compared to the a priori profiles without lightning. As first priority, a priori vertical NO2 profiles from a chemical transport model with a high resolution, which can better simulate urban-rural NO2 gradients in the boundary layer and make use of observation-based parameterizations of lightning NOx production, should be first implemented to obtain more accurate NO2 retrievals over the United States, where NOx source regions are spatially separated and lightning NOx production is significant. Then as consequence of a priori NO2 profile variabilities resulting from lightning and model resolution dynamics, geostationary satellite, daylight observations would further promote the next step towards producing a more complete NO2 data product provided sufficient resolution of the observations. Both the corrected retrieval algorithm and the proposed next generation geostationary satellite observations would thus improve emission inventories, better validate model simulations, and advantageously optimize regional specific ozone control strategies.
Properties of coarse particles in suspended particulate matter of the North Yellow Sea during summer
NASA Astrophysics Data System (ADS)
Zhang, Kainan; Wang, Zhenyan; Li, Wenjian; Yan, Jun
2018-01-01
Fine particles in seawater commonly form large porous aggregates. Aggregate density and settling velocity determine the behavior of this suspended particulate matter (SPM) within the water column. However, few studies of aggregate particles over a continental shelf have been undertaken. In our case study, properties of aggregate particles, including size and composition, over the continental shelf of the North Yellow Sea were investigated. During a scientific cruise in July 2016, in situ effective particle size distributions of SPM at 10 stations were measured, while temperature and turbidity measurements and samples of water were obtained from surface, middle, and bottom layers. Dispersed and inorganic particle size distributions were determined in the laboratory. The in situ SPM was divided into (1) small particles (<32 μm), (2) medium particles (32-256 μm) and (3) large particles (>256 μm). Large particles and medium particles dominated the total volume concentrations (VCs) of in situ SPM. After dispersion, the VCs of medium particles decreased to low values (<0.1 μL/L). The VCs of large particles in the surface and middle layers also decreased markedly, although they had higher peak values (0.1-1 μL/L). This suggests that almost all in situ medium particles and some large particles were aggregated, while other large particles were single particles. Correlation analysis showed that primary particles <32 μm influenced the formation of these aggregates. Microscopic examination revealed that these aggregates consisted of both organic and inorganic fine particles, while large particles were mucus-bound organic aggregates or individual plankton. The vertical distribution of coarser particles was clearly related to water stratification. Generally, medium aggregate particles were dominant in SPM of the bottom layer. A thermocline blocked resuspension of fine material into upper layers, yielding low VCs of medium-sized aggregate particles in the surface layer. Abundant large biogenic particles were present in both surface and middle layers.
Lhermie, Guillaume; Dupouy, Véronique; El Garch, Farid; Ravinet, Nadine; Toutain, Pierre-Louis; Bousquet-Mélou, Alain; Seegers, Henri; Assié, Sébastien
2017-03-01
In the context of requested decrease of antimicrobial use in veterinary medicine, our objective was to assess the impact of two doses of marbofloxacin administered on young bulls (YBs) and veal calves (VCs) treated for bovine respiratory disease, on the total population of Enterobacteriaceae in gut flora and on the emergence of resistant Enterobacteriaceae. In two independent experiments, 48 YBs from 6 commercial farms and 33 VCs previously colostrum deprived and exposed to cefquinome were randomly assigned to one of the three groups LOW, HIGH, and Control. In LOW and HIGH groups, animals received a single injection of, respectively, 2 and 10 mg/kg marbofloxacin. Feces were sampled before treatment, and at several times after treatment. Total and resistant Enterobacteriaceae enumerating were performed by plating dilutions of fecal samples on MacConkey agar plates that were supplemented or not with quinolone. In YBs, marbofloxacin treatment was associated with a transient decrease in total Enterobacteriaceae count between day (D)1 and D3 after treatment. Total Enterobacteriaceae count returned to baseline between D5 and D7 in all groups. None of the 48 YBs harbored marbofloxacin-resistant Enterobacteriaceae before treatment. After treatment, 1 out of 20 YBs from the Control group and 1 out of 14 YBs from the HIGH group exhibited marbofloxacin-resistant Enterobacteriaceae. In VCs, the rate of fluoroquinolone-resistant Enterobacteriaceae significantly increased after low and high doses of marbofloxacin treatment. However, the effect was similar for the two doses, which was probably related to the high level of resistant Enterobacteriaceae exhibited before treatment. Our results suggest that a single treatment with 2 or 10 mg/kg marbofloxacin exerts a moderate selective pressure on commensal Enterobacteriaceae in YBs and in VCs. A fivefold decrease of marbofloxacin regimen did not affect the selection of resistances among commensal bacteria.
Da Costa, A P; Broad, K D; Kendrick, K M
1997-06-01
In sheep maternal behaviour and the formation of the selective olfactory, ewe/lamb bond are induced by feedback to the brain from stimulation of the vagina and cervix during parturition. In the present study, we have used in situ hybridization histochemistry to quantify changes in cellular expression of two immediately-early genes, c-fos and zif/268, in order to identify activated brain regions during the induction of maternal behaviour and olfactory bonding as well as regions where plastic changes are occurring during with the formation of the olfactory memory associated with bonding. Three different treatment groups were used. One group gave birth normally, became maternal and were allowed to interact with their lambs for 30 min. A second group received exogenous treatment with oestradiol and progesterone to induce lactation and then received a 5-min period of artificial stimulation of the vagina and cervix (VCS) which reliably induces maternal behaviour but could not interact with lambs. A final control group received exogenous hormone treatment but no VCS or interaction with lambs. Compared to the control group, post-partum animals and animals that had received VCS showed increased c-fos expression in a number of cortical regions (cingulate, entorhinal and somatosensory), the mediodorsal thalamic nucleus and the lateral habenula, the limbic system (bed nucleus of the stria terminalis, lateral septum, medial arnygdala, dentate gyrus and the CA3 region of the hippocampus) and the hypothalamus (medial preoptic area, mediobasal hypothalamus, paraventricular nucleus, supraoptic nucleus and periventricular complex). The group that gave birth and had contact with their lambs for 30 min had significantly enhanced c-fos mRNA expression in the cingulate cortex compared to those receiving VCS and additionally showed significantly increased c-fos mRNA expression in olfactory processing regions (olfactory bulb, piriform cortex and orbitofrontal cortex). Expression of zif/268 was significantly increased in the entorhinal cortex, orbitofrontal cortex and dentate gyrus of the parturition group compared to either the control or the VCS alone groups. These results show a clear differentiation between neural substrates controlling the expression of maternal behaviour and those involved in the olfactory memory process associated with selective recognition of offspring although at the level of the hippocampus and cingulate cortex there may be some degree of overlap. Alterations in zif/268 at tertiary processing sites for olfactory information (orbitofrontal cortex) and the entorhinal cortex and dentate gyrus may reflect plastic changes occurring during the early stages of olfactory memory formation.
Shoemaker, Ritchie C; House, Dennis E
2006-01-01
Occupants of water-damaged buildings (WDBs) with evidence of microbial amplification often describe a syndrome involving multiple organ systems, commonly referred to as "sick building syndrome" (SBS), following chronic exposure to the indoor air. Studies have demonstrated that the indoor air of WDBs often contains a complex mixture of fungi, mycotoxins, bacteria, endotoxins, antigens, lipopolysaccharides, and biologically produced volatile compounds. A case-series study with medical assessments at five time points was conducted to characterize the syndrome after a double-blinded, placebo-controlled clinical trial conducted among a group of study participants investigated the efficacy of cholestyramine (CSM) therapy. The general hypothesis of the time series study was that chronic exposure to the indoor air of WDBs is associated with SBS. Consecutive clinical patients were screened for diagnosis of SBS using criteria of exposure potential, symptoms involving at least five organ systems, and the absence of confounding factors. Twenty-eight cases signed voluntary consent forms for participation in the time-series study and provided samples of microbial contaminants from water-damaged areas in the buildings they occupied. Twenty-six participants with a group-mean duration of illness of 11 months completed examinations at all five study time points. Thirteen of those participants also agreed to complete a double-blinded, placebo-controlled clinical trial. Data from Time Point 1 indicated a group-mean of 23 out of 37 symptoms evaluated; and visual contrast sensitivity (VCS), an indicator of neurological function, was abnormally low in all participants. Measurements of matrix metalloproteinase 9 (MMP9), leptin, alpha melanocyte stimulating hormone (MSH), vascular endothelial growth factor (VEGF), immunoglobulin E (IgE), and pulmonary function were abnormal in 22, 13, 25, 14, 1, and 7 participants, respectively. Following 2 weeks of CSM therapy to enhance toxin elimination rates, measurements at Time Point 2 indicated group-means of 4 symptoms with 65% improvement in VCS at mid-spatial frequency-both statistically significant improvements relative to Time Point 1. Moderate improvements were seen in MMP9, leptin, and VEGF serum levels. The improvements in health status were maintained at Time Point 3 following a 2-week period during which CSM therapy was suspended and the participants avoid re-exposure to the WDBs. Participants reoccupied the respective WDBs for 3 days without CSM therapy, and all participants reported relapse at Time Point 4. The group-mean number of symptoms increased from 4 at Time Point 2 to 15 and VCS at mid-spatial frequency declined by 42%, both statistically significant differences relative to Time Point 2. Statistically significant differences in the group-mean levels of MMP9 and leptin relative to Time Point 2 were also observed. CSM therapy was reinstated for 2 weeks prior to assessments at Time Point 5. Measurements at Time Point 5 indicated group-means of 3 symptoms and a 69% increase in VCS, both results statistically different from those at Time Points 1 and 4. Optically corrected Snellen Distance Equivalent visual acuity scores did not vary significantly over the course of the study. Group-mean levels of MMP9 and leptin showed statistically significant improvement at Time Point 5 relative to Time Points 1 and 4, and the proportion of participants with abnormal VEGF levels was significantly lower at Time Point 5 than at Time Point 1. The number of participants at Time Point 5 with abnormal levels of MMP9, leptin, VEGF, and pulmonary function were 10, 10, 9, and 7, respectively. The level of IgE was not re-measured because of the low incidence of abnormality at Time Point 1, and MSH was not re-measured because previously published data indicated a long time course for MSH improvement. The results from the time series study supported the general study hypothesis that exposure to the indoor air of WDBs is associated with SBS. High levels of MMP9 indicated that exposure to the complex mixture of substances in the indoor air of the WDBs triggered a pro-inflammatory cytokine response. A model describing modes of action along a pathway leading to biotoxin-associated illness is presented to organize current knowledge into testable hypotheses. The model links an inflammatory response with tissue hypoxia, as indicated by abnormal levels of VEGF, and disruption of the proopiomelanocortin pathway in the hypothalamus, as evidenced by abnormalities in leptin and MSH levels. Results from the clinical trial on CSM efficacy indicated highly significant improvement in group-mean number of symptoms and VCS scores relative to baseline in the 7 participants randomly assigned to receive 2 weeks of CSM therapy, but no improvement in the 6 participants assigned placebo therapy during that time interval. However, those 6 participants also showed a highly significant improvement in group-mean number of symptoms and VCS scores relative to baseline following a subsequent 2-week period of CSM therapy. Because the only known benefit of CSM therapy is to enhance the elimination rates of substances that accumulate in bile by preventing re-absorption during enterohepatic re-circulation, results from the clinical trial also supported the general study hypothesis that SBS is associated with exposure to WDBs because the only relevant function of CSM is to bind and remove toxigenic compounds. Only research that focuses on the signs, symptoms, and biochemical markers of patients with persistent illness following acute and/or chronic exposure to WDBs can further the development of the model describing modes of action in the biotoxin-associated pathway and guide the development of innovative and efficacious therapeutic interventions.
NASA Astrophysics Data System (ADS)
Fonvieille, H.; Laveissière, G.; Degrande, N.; Jaminion, S.; Jutier, C.; Todor, L.; Di Salvo, R.; Van Hoorebeke, L.; Alexa, L. C.; Anderson, B. D.; Aniol, K. A.; Arundell, K.; Audit, G.; Auerbach, L.; Baker, F. T.; Baylac, M.; Berthot, J.; Bertin, P. Y.; Bertozzi, W.; Bimbot, L.; Boeglin, W. U.; Brash, E. J.; Breton, V.; Breuer, H.; Burtin, E.; Calarco, J. R.; Cardman, L. S.; Cavata, C.; Chang, C.-C.; Chen, J.-P.; Chudakov, E.; Cisbani, E.; Dale, D. S.; de Jager, C. W.; De Leo, R.; Deur, A.; d'Hose, N.; Dodge, G. E.; Domingo, J. J.; Elouadrhiri, L.; Epstein, M. B.; Ewell, L. A.; Finn, J. M.; Fissum, K. G.; Fournier, G.; Frois, B.; Frullani, S.; Furget, C.; Gao, H.; Gao, J.; Garibaldi, F.; Gasparian, A.; Gilad, S.; Gilman, R.; Glamazdin, A.; Glashausser, C.; Gomez, J.; Gorbenko, V.; Grenier, P.; Guichon, P. A. M.; Hansen, J. O.; Holmes, R.; Holtrop, M.; Howell, C.; Huber, G. M.; Hyde, C. E.; Incerti, S.; Iodice, M.; Jardillier, J.; Jones, M. K.; Kahl, W.; Kato, S.; Katramatou, A. T.; Kelly, J. J.; Kerhoas, S.; Ketikyan, A.; Khayat, M.; Kino, K.; Kox, S.; Kramer, L. H.; Kumar, K. S.; Kumbartzki, G.; Kuss, M.; Leone, A.; LeRose, J. J.; Liang, M.; Lindgren, R. A.; Liyanage, N.; Lolos, G. J.; Lourie, R. W.; Madey, R.; Maeda, K.; Malov, S.; Manley, D. M.; Marchand, C.; Marchand, D.; Margaziotis, D. J.; Markowitz, P.; Marroncle, J.; Martino, J.; McCormick, K.; McIntyre, J.; Mehrabyan, S.; Merchez, F.; Meziani, Z. E.; Michaels, R.; Miller, G. W.; Mougey, J. Y.; Nanda, S. K.; Neyret, D.; Offermann, E. A. J. M.; Papandreou, Z.; Pasquini, B.; Perdrisat, C. F.; Perrino, R.; Petratos, G. G.; Platchkov, S.; Pomatsalyuk, R.; Prout, D. L.; Punjabi, V. A.; Pussieux, T.; Quémenér, G.; Ransome, R. D.; Ravel, O.; Real, J. S.; Renard, F.; Roblin, Y.; Rowntree, D.; Rutledge, G.; Rutt, P. M.; Saha, A.; Saito, T.; Sarty, A. J.; Serdarevic, A.; Smith, T.; Smirnov, G.; Soldi, K.; Sorokin, P.; Souder, P. A.; Suleiman, R.; Templon, J. A.; Terasawa, T.; Tieulent, R.; Tomasi-Gustaffson, E.; Tsubota, H.; Ueno, H.; Ulmer, P. E.; Urciuoli, G. M.; Vanderhaeghen, M.; Van der Meer, R. L. J.; Van De Vyver, R.; Vernin, P.; Vlahovic, B.; Voskanyan, H.; Voutier, E.; Watson, J. W.; Weinstein, L. B.; Wijesooriya, K.; Wilson, R.; Wojtsekhowski, B. B.; Zainea, D. G.; Zhang, W.-M.; Zhao, J.; Zhou, Z.-L.
2012-07-01
Virtual Compton scattering (VCS) on the proton has been studied at the Jefferson Laboratory using the exclusive photon electroproduction reaction ep→epγ. This paper gives a detailed account of the analysis which has led to the determination of the structure functions PLL-PTT/ɛ and PLT and the electric and magnetic generalized polarizabilities (GPs) αE(Q2) and βM(Q2) at values of the four-momentum transfer squared Q2=0.92 and 1.76 GeV2. These data, together with the results of VCS experiments at lower momenta, help building a coherent picture of the electric and magnetic GPs of the proton over the full measured Q2 range and point to their nontrivial behavior.
Suárez, M M; Rivarola, M A; Molina, S M; Levin, G M; Enders, J; Paglini, P
2004-09-01
Maternal separation can interfere with growth and development of the brain and represents a significant risk factor for adult psychopathology. In rodents, prolonged separation from the mother affects the behavioral and endocrine responses to stress for the lifetime of the animal. Limbic structures such as the anterodorsal thalamic nuclei (ADTN) play an important role in the control of neuroendocrine and sympathetic-adrenal function. In view of these findings we hypothesized that the function of the ADTN may be affected in an animal model of maternal deprivation. To test this hypothesis female rats were isolated 4.5 h daily, during the first 3 weeks of life and tested as adults. We evaluated plasma epinephrine (E) and norepinephrine (NE), cardiac adrenoreceptors and anxiety responses after maternal deprivation and variable chronic stress (VCS) in ADTN-lesioned rats. Thirty days after ADTN lesion, in non-maternally deprived rats basal plasma NE concentration was greater and cardiac beta-adrenoreceptor density was lower than that in the sham-lesioned group. Maternal deprivation induced a significant increase in basal plasma NE concentration, which was greater in lesioned rats, and cardiac beta-adrenoreceptor density was decreased in lesioned rats. After VCS plasma catecholamine concentration was much greater in non-maternally deprived rats than in maternally-deprived rats; cardiac beta-adrenoreceptor density was decreased by VCS in both maternally-deprived and non-deprived rats, but more so in non-deprived rats, and further decreased by the ADTN lesion. In the plus maze test, the number of open arm entries was greater in the maternally deprived and in the stressed rats. Thus, sympathetic-adrenal medullary activation produced by VCS was much greater in non-deprived rats, and was linked to a down regulation of myocardial beta-adrenoceptors. The ADTN are not responsible for the reduced catecholamine responses to stress in maternally-deprived rats. Maternal deprivation or chronic stress also induced a long term anxiolytic effect, which was also not affected by ADTN lesion.
Automated longwall guidance and control systems, phase 1
NASA Technical Reports Server (NTRS)
Rybak, S. C.
1978-01-01
Candidate vertical control systems (VCS) and face advancement systems (FAS) required to satisfactorily automate the longwall system were analyzed and simulated in order to develop an overall longwall system configuration for preliminary design.
Hernández-Calderón, Erasto; Aviles-Garcia, Maria Elizabeth; Castulo-Rubio, Diana Yazmín; Macías-Rodríguez, Lourdes; Ramírez, Vicente Montejano; Santoyo, Gustavo; López-Bucio, José; Valencia-Cantero, Eduardo
2018-02-01
Our results show that Sorghum bicolor is able to recognize bacteria through its volatile compounds and differentially respond to beneficial or pathogens via eliciting nutritional or defense adaptive traits. Plants establish beneficial, harmful, or neutral relationships with bacteria. Plant growth promoting rhizobacteria (PGPR) emit volatile compounds (VCs), which may act as molecular cues influencing plant development, nutrition, and/or defense. In this study, we compared the effects of VCs produced by bacteria with different lifestyles, including Arthrobacter agilis UMCV2, Bacillus methylotrophicus M4-96, Sinorhizobium meliloti 1021, the plant pathogen Pseudomonas aeruginosa PAO1, and the commensal rhizobacterium Bacillus sp. L2-64, on S. bicolor. We show that VCs from all tested bacteria, except Bacillus sp. L2-64, increased biomass and chlorophyll content, and improved root architecture, but notheworthy A. agilis induced the release of attractant molecules, whereas P. aeruginosa activated the exudation of growth inhibitory compounds by roots. An analysis of the expression of iron-transporters SbIRT1, SbIRT2, SbYS1, and SbYS2 and genes related to plant defense pathways COI1 and PR-1 indicated that beneficial, pathogenic, and commensal bacteria could up-regulate iron transporters, whereas only beneficial and pathogenic species could induce a defense response. These results show how S. bicolor could recognize bacteria through their volatiles profiles and highlight that PGPR or pathogens can elicit nutritional or defensive traits in plants.
Radiographic identification of the equine ventral conchal bulla.
Finnegan, C M; Townsend, N B; Barnett, T P; Barakzai, S Z
Involvement of the ventral conchal sinus (VCS) is an important diagnostic and prognostic feature in cases of the equine sinus disease. The authors aimed to ascertain if the caudo-dorsal extension of the VCS, the ventral conchal bulla (VCB) is identifiable on plain radiographs of cadaver skulls without sinus disease. Bilateral frontonasal sinus flaps were made in 10 equine cadaver skulls. Plain lateral, lateral oblique and dorso-ventral radiographs were then obtained followed by the same views taken with stainless steel wire outlining the caudal border of the VCB. Plain radiographs were randomised and blindly evaluated by two observers who marked where they believed the VCB to be positioned. This was then correlated with the true position of the VCB using radiographs with wires in place. The ease of identification of the VCB was classified as 'easy' or 'difficult'. The VCB was correctly identified in 70 per cent of lateral radiographs, but only 45 per cent of lateral oblique radiographs and 17 per cent of dorso-ventral radiographs. If a clinician was confident that he or she could identify the VCB, they were usually correct. Conversely if the clinician judged VCB identification as 'difficult', they usually identified it incorrectly. In the authors' clinical experience, the VCB of horses with sinusitis involving this compartment is more radiologically evident than in clinically normal horses. Knowledge of the normal radiographic anatomy of this structure should aid clinicians in identifying horses with sinusitis affecting the VCS.
Improving substructure identification accuracy of shear structures using virtual control system
NASA Astrophysics Data System (ADS)
Zhang, Dongyu; Yang, Yang; Wang, Tingqiang; Li, Hui
2018-02-01
Substructure identification is a powerful tool to identify the parameters of a complex structure. Previously, the authors developed an inductive substructure identification method for shear structures. The identification error analysis showed that the identification accuracy of this method is significantly influenced by the magnitudes of two key structural responses near a certain frequency; if these responses are unfavorable, the method cannot provide accurate estimation results. In this paper, a novel method is proposed to improve the substructure identification accuracy by introducing a virtual control system (VCS) into the structure. A virtual control system is a self-balanced system, which consists of some control devices and a set of self-balanced forces. The self-balanced forces counterbalance the forces that the control devices apply on the structure. The control devices are combined with the structure to form a controlled structure used to replace the original structure in the substructure identification; and the self-balance forces are treated as known external excitations to the controlled structure. By optimally tuning the VCS’s parameters, the dynamic characteristics of the controlled structure can be changed such that the original structural responses become more favorable for the substructure identification and, thus, the identification accuracy is improved. A numerical example of 6-story shear structure is utilized to verify the effectiveness of the VCS based controlled substructure identification method. Finally, shake table tests are conducted on a 3-story structural model to verify the efficacy of the VCS to enhance the identification accuracy of the structural parameters.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-03
.... Veterans Canteen Service (VCS) now operates franchise coffee bars, staffed with NAF employees, at..., Government employees, Reporting and recordkeeping requirements, Wages. U.S. Office of Personnel Management...
75 FR 81204 - Notice of Public Information Collection Requirements Submitted to OMB for Review
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-27
...: OMB Number: OMB 0412-New. Form Number: N/A. Title: USAID Visa Compliance System (VCS). Type of... objectives by supporting: Economic growth, agriculture and trade; global health; and democracy conflict...
NASA Astrophysics Data System (ADS)
Volkov, M. V.; Kostrova, D. A.; Margaryants, N. B.; Gurov, I. P.; Erofeev, N. P.; Dremin, V. V.; Zharkikh, E. V.; Zherebtsov, E. A.; Kozlov, I. O.; Dunaev, A. V.
2017-03-01
Laser Doppler flowmetry (LDF) is widely used for diagnosing blood microcirculation diseases. It is well known that the Doppler shift of laser radiation scattered by moving red blood cells (RBC) can be assessed through analyzing photocurrent produced by a photodetector. LDF signal contains information about regulating blood flow rhythms: myogenic, cardiac, nervous and endothelial. The method of videocapillaroscopy (VCS) allows local capillary blood flow velocity evaluation and, using video data processing algorithms, is able to assess RBC velocity changes into capillary. We present the results of simultaneous investigations of changes in tissue perfusion of the distal phalanx of human finger by the LDF as well as changes in capillary blood flow velocity in the nail bed evaluated by the VCS method during arterial occlusion test. The experimental results confirmed the correspondence between blood perfusion and blood flow velocity.
Searching for Super Massive Binary Black Holes in the VLBA Calibrator Survey
NASA Astrophysics Data System (ADS)
High, Brittney C.; Peck, Alison B.; Beasley, Anthony J.
2016-01-01
Due to its incredible resolving power, the Very Long Baseline Array (VLBA) allows astronomers to view radio emission from celestial objects in incredible detail. This makes the VLBA the best instrument for studying the dynamics of active galactic nuclei, or compact regions at the centers of galaxies where black holes are thought to reside. Since most galaxies harbor supermassive black holes at their centers, and some galaxies merge with others, supermassive binary black hole systems arise. Though a number of these systems have been found, only one system contains black holes within 10 pc apart. During the summer, we analyzed new observations from the VLBA Calibrator Survey (VCS) on approximately 2200 sources in the hopes of detecting more close supermassive binary black hole candidates. Here we present the results from reducing and categorizing these sources. We also discuss the importance of the VCS and its role in enabling observations of the most distant celestial objects.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blomberg, Adam
Non-spherical components of the nucleon wave function are measured through p(e,e'p)π 0 experiment at the Δ +(1232) resonance for Q 2 = 0.04, 0.09, and 0.13 (GeV=c) 2 utilizing the Jefferson National Accelerator Facility (JLab) pulsed beam and Hall A spectrometers. The new data extend the measurements of the Coulomb quadrupole amplitude to the lowest momentum transfer ever reached. The results disagree with predictions of constituent quark models and are in reasonable agreement with dynamical calculations that include pion cloud effects, chiral effective field theory and lattice calculations. The reported measurements indicate that improvement is required to the theoretical calculationsmore » and provide valuable input that will allow their refinements. The Coulomb to magnetic multipole ratio (CMR) and generalized polarizability (GP) of the nucleon are also measured through virtual Compton scattering (VCS) for Q 2 = 0.2(GeV=c) 2 utilizing the Mainz Microtron (MAMI) continuous beam and A1 spectrometers. This data represents the first low Q 2 GP measurement at the Δ +(1232) resonance. The GP measurement explores a region where previous data and theoretical calculations disagree. The CMR measurement will be the first VCS extraction to compare with world data generated through pion electroproduction. The Dispersion Relation (DR) model used for the VCS extraction provides a new theoretical framework for the data signal and backgrounds that is largely independent from the pion electroproduction models. The independence of the DR from the traditional models provides a strong crosscheck on the ability of the models to isolate the data signal.« less
On a viscous critical-stress model of martensitic phase transitions
NASA Astrophysics Data System (ADS)
Weatherwax, John; Vaynblat, Dimitri; Bruno, Oscar; Rosales, Ruben
2007-09-01
The solid-to-solid phase transitions that result from shock loading of certain materials, such as the graphite-to-diamond transition and the α-ɛ transition in iron, have long been subjects of a substantial theoretical and experimental literature. Recently a model for such transitions was introduced which, based on a CS condition (CS) and without use of fitting parameters, accounts quantitatively for existing observations in a number of systems [Bruno and Vaynblat, Proc. R. Soc. London, Ser. A 457, 2871 (2001)]. While the results of the CS model match the main features of the available experimental data, disagreements in some details between the predictions of this model and experiment, attributable to an ideal character of the CS model, do exist. In this article we present a version of the CS model, the viscous CS model (vCS), as well as a numerical method for its solution. This model and the corresponding solver results in a much improved overall CS modeling capability. The innovations we introduce include: (1) Enhancement of the model by inclusion of viscous phase-transition effects; as well as a numerical solver that allows for a fully rigorous treatment of both, the (2) Rarefaction fans (which had previously been approximated by "rarefaction discontinuities"), and (3) viscous phase-transition effects, that are part of the vCS model. In particular we show that the vCS model accounts accurately for well known "gradual" rises in the α-ɛ transition which, in the original CS model, were somewhat crudely approximated as jump discontinuities.
Vascular access registry of Serbia: a 4-year experience.
Jemcov, Tamara; Dimkovic, Nada
2017-02-01
Adequate and functional long-term vascular access (VA) is pivotal for the efficient hemodialysis (HD). It has been shown that the most reliable VA is autogenous arteriovenous fistulas (AVFs) as compared with arteriovenous grafts (AVGs) and vascular catheters (VCs). The vascular access register (VAR) has been established since 2010, and the 4-year trend of VA in Serbia is presented in this paper. All HD centers in Serbia provided their data by fulfilling the questionnaire that included prevalent and incident HD patients on December 31, 2010-1013. AVF is the most frequent prevalent VA (89.5-93.1 %) and also the most frequent newly created VA (87-89 %) during the observational period. The number of preemptive AVF is increasing, but it is still low (7.8 % in 2010 and 14.6 % in 2013). The percentage of incident AVG is constant (~3.4 %) as well as the number of permanent VC (8.2 % in 2010 and 7.8 % in 2013). The number of incident patients who started HD with AVF is decreasing (from 37 to 27 %), and the number of urgent start with VC is on the increase (from 63 to 73 %). In almost all relevant dialysis centers, vascular access is created by surgeons. Temporal VCs are placed by anesthesiologists (all centers), nephrologists (up to 25 % of centers) and vascular surgeons (up to 20 %). VCs are located mainly in jugular vein, but the number of femoral catheters remains high (up to 69 %). Although we have favorable data, the VAR is of a great importance and ensures continuous quality improvement.
Martin-StPaul, N K; Longepierre, D; Huc, R; Delzon, S; Burlett, R; Joffre, R; Rambal, S; Cochard, H
2014-08-01
Three methods are in widespread use to build vulnerability curves (VCs) to cavitation. The bench drying (BD) method is considered as a reference because embolism and xylem pressure are measured on large branches dehydrating in the air, in conditions similar to what happens in nature. Two other methods of embolism induction have been increasingly used. While the Cavitron (CA) uses centrifugal force to induce embolism, in the air injection (AI) method embolism is induced by forcing pressurized air to enter a stem segment. Recent studies have suggested that the AI and CA methods are inappropriate in long-vesselled species because they produce a very high-threshold xylem pressure for embolism (e.g., P50) compared with what is expected from (i) their ecophysiology in the field (native embolism, water potential and stomatal response to xylem pressure) and (ii) the P50 obtained with the BD method. However, other authors have argued that the CA and AI methods may be valid because they produce VCs similar to the BD method. In order to clarify this issue, we assessed VCs with the three above-mentioned methods on the long-vesselled Quercus ilex L. We showed that the BD VC yielded threshold xylem pressure for embolism consistent with in situ measurements of native embolism, minimal water potential and stomatal conductance. We therefore concluded that the BD method provides a reliable estimate of the VC for this species. The CA method produced a very high P50 (i.e., less negative) compared with the BD method, which is consistent with an artifact related to the vessel length. The VCs obtained with the AI method were highly variable, producing P50 ranging from -2 to -8.2 MPa. This wide variability was more related to differences in base diameter among samples than to differences in the length of samples. We concluded that this method is probably subject to an artifact linked to the distribution of vessel lengths within the sample. Overall, our results indicate that the CA and the AI should be used with extreme caution on long-vesselled species. Our results also highlight that several criteria may be helpful to assess the validity of a VC. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Asakawa, Eiichi; Murakami, Fumitoshi; Tsukahara, Hitoshi; Saito, Shutaro; Lee, Sangkyun; Tara, Kenji; Kato, Masafumi; Jamali Hondori, Ehsan; Sumi, Tomonori; Kadoshima, Kazuyuki; Kose, Masami
2017-04-01
Within the EEZ of Japan, numerous surveys exploring ocean floor resources have been conducted. The exploration targets are gas hydrates, mineral resources (manganese, cobalt or rare earth) and especially seafloor massive sulphide (SMS) deposits. These resources exist in shallow subsurface areas in deep waters (>1500m). For seismic explorations very high resolution images are required. These cannot be effectively obtained with conventional marine seismic techniques. Therefore we have been developing autonomous seismic survey systems which record the data close to the seafloor to preserve high frequency seismic energy. Very high sampling rate (10kHz) and high accurate synchronization between recording systems and shot time are necessary. We adopted Cs-base atomic clock considering its power consumption. At first, we developed a Vertical Cable Seismic (VCS) system that uses hydrophone arrays moored vertically from the ocean bottom to record close to the target area. This system has been successfully applied to SMS exploration. Specifically it fixed over known sites to assess the amount of reserves with the resultant 3D volume. Based on the success of VCS, we modified the VCS system to use as a more efficient deep-tow seismic survey system. Although there are other examples of deep-tow seismic systems, signal transmission cables present challenges in deep waters. We use our autonomous recording system to avoid these problems. Combining a high frequency piezoelectric source (Sub Bottom Profiler:SBP) that automatically shots with a constant interval, we achieve the high resolution deep-tow seismic without data transmission/power cable to the board. Although the data cannot be monitored in real-time, the towing system becomes very simple. We have carried out survey trial, which showed the systems utility as a high-resolution deep-tow seismic survey system. Furthermore, the frequency ranges of deep-towed source (SBP) and surface towed sparker are 700-2300Hz and 10-200Hz respectively. Therefore we can use these sources simultaneously and distinguish the records of each source in the data processing stage. We have developed new marine seismic survey systems with autonomous recording for the exploration of the ocean floor resources. The applications are vertical cable seismic (VCS) and deep-tow seismic (ACS). These enable us the recording close to the seafloor and give the high resolution results with a simple, cost-effective configuration.
Denawaka, Chamila J; Fowlis, Ian A; Dean, John R
2014-04-18
An evaluation of static headspace-multicapillary column-gas chromatography-ion mobility spectrometry (SHS-MCC-GC-IMS) has been undertaken to assess its applicability for the determination of 32 volatile compounds (VCs). The key experimental variables of sample incubation time and temperature have been evaluated alongside the MCC-GC variables of column polarity, syringe temperature, injection temperature, injection volume, column temperature and carrier gas flow rate coupled with the IMS variables of temperature and drift gas flow rate. This evaluation resulted in six sets of experimental variables being required to separate the 32 VCs. The optimum experimental variables for SHS-MCC-GC-IMS, the retention time and drift time operating parameters were determined; to normalise the operating parameters, the relative drift time and normalised reduced ion mobility for each VC were determined. In addition, a full theoretical explanation is provided on the formation of the monomer, dimer and trimer of a VC. The optimum operating condition for each VC calibration data was obtained alongside limit of detection (LOD) and limit of quantitation (LOQ) values. Typical detection limits ranged from 0.1ng bis(methylthio)methane, ethylbutanoate and (E)-2-nonenal to 472ng isovaleric acid with correlation coefficient (R(2)) data ranging from 0.9793 (for the dimer of octanal) through to 0.9990 (for isobutyric acid). Finally, the developed protocols were applied to the analysis of malodour in sock samples. Initial work involved spiking an inert matrix and sock samples with appropriate concentrations of eight VCs. The average recovery from the inert matrix was 101±18% (n=8), while recoveries from the sock samples were lower, that is, 54±30% (n=8) for sock type 1 and 78±24% (n=6) for sock type 2. Finally, SHS-MCC-GC-IMS was applied to sock malodour in a field trial based on 11 volunteers (mixed gender) over a 3-week period. By applying the SHS-MCC-GC-IMS database, four VCs were identified and quantified: ammonia, dimethyl disulphide, dimethyl trisulphide and butyric acid. A link was identified between the presence of high ammonia and dimethyl disulphide concentrations and a high malodour odour grading, that is, ≥ 6. Statistical analysis did not find any correlation between the occurrence of dimethyl disulphide and participant gender. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.
Laser welding for vascular anastomosis using albumin solder: an approach for MID-CAB.
Phillips, A B; Ginsburg, B Y; Shin, S J; Soslow, R; Ko, W; Poppas, D P
1999-01-01
To improve minimally invasive direct coronary artery bypass surgery (MID-CAB), new techniques of vascular anastomosis that are faster and more reliable need to be developed. Common carotids in a canine model were transected and an end-to-end anastomosis was performed by using one of four techniques (1) continuous 6-0 polypropylene closure (suture; n=6), (2) vascular clip (VCS; n=6), laser welding using 50% albumin solder with (3) a 1.32-micro laser (1.32las; n=6), and (4) a 1.9-micro diode laser (1.9las; n=4). Times for anastomosis (TA) were compared between groups by t-test. Pressures at which anastomosis failed (leak point pressure, LPP) were determined and compared by analysis of variance. TA was faster for 1.32las and 1.9las at 8.4+/-0.7 and 7.8+/-0.3 min, respectively, when compared with suture at 13.8+/-1.0 min (P=0.001, confidence interval [CI]-8.1, -2.6 for 1.32las and CI -8.9, -3.1 for 1.9las). There was no statistical difference between VCS (8.3+/-3.3 min) and any other group (P > 0.17). LPPs (mm Hg) were similar for all groups: 350+/-37 for 1.32las, 280+/-31 for 1.9las, 347+/-46 for suture, and 358+/-53 for VCS, P=0.68. In this study, laser welding using 50% human albumin solder resulted in faster anastomotic times. Anastomoses were equivalent to conventional sutured anastomoses in failing at similar pressures. Laser welding using human albumin solder may be advantageous in improving coronary anastomoses during MID-CAB, but long-term anastomotic strength and histologic evaluation need to be investigated.
Online Videoconferencing Products: Update
ERIC Educational Resources Information Center
Burton, Douglas; Kitchen, Tim
2011-01-01
Software allowing real-time online video connectivity is rapidly evolving. The ability to connect students, staff, and guest speakers instantaneously carries great benefits for the online distance education classroom. This evaluation report compares four software applications at opposite ends of the cost spectrum: "DimDim", "Elluminate VCS",…
A new method for registration of heterogeneous sensors in a dimensional measurement system
NASA Astrophysics Data System (ADS)
Zhao, Yan; Wang, Zhong; Fu, Luhua; Qu, Xinghua; Zhang, Heng; Liu, Changjie
2017-10-01
Registration of multiple sensors is a basic step in multi-sensor dimensional or coordinate measuring systems before any measurement. In most cases, a common standard is used to be measured by all sensors, and this may work well for general registration of multiple homogeneous sensors. However, when inhomogeneous sensors detect a common standard, it is usually very difficult to obtain the same information, because of the different working principles of the sensors. In this paper, a new method called multiple steps registration is proposed to register two sensors: a video camera sensor (VCS) and a tactile probe sensor (TPS). In this method, the two sensors measure two separated standards: a chrome circle on a reticle and a reference sphere with a constant distance between them, fixed on a steel plate. The VCS captures only the circle and the TPS touches only the sphere. Both simulations and real experiments demonstrate that the proposed method is robust and accurate in the registration of multiple inhomogeneous sensors in a dimensional measurement system.
Solid waste management of temple floral offerings by vermicomposting using Eisenia fetida.
Singh, Akanksha; Jain, Akansha; Sarma, Birinchi K; Abhilash, P C; Singh, Harikesh B
2013-05-01
Recycling of temple waste (TW) mainly comprising of floral offerings was done through vermitechnology using Eisenia fetida and its impact on seed germination and plant growth parameters was studied by comparing with kitchen waste (KW) and farmyard waste (FYW) vermicompost (VC). The worm biomass was found to be maximum in TW VC compared to KW and FYW VCs at both 40 and 120days old VCs. Physico-chemical analysis of worm-worked substrates showed better results in TW VC especially in terms of electrical conductivity, C/N, C/P and TK. 10% TW VC-water extract (VCE) showed stimulatory effect on germination percentage of chickpea seeds while KW and FYW VCE proved effective at higher concentration. Variation in growth parameters was also observed with change in the VC-soil ratio and TW VC showed enhanced shoot length, root length, number of secondary roots and total biomass at 12.5% VC compared to KW and FYW VC. Copyright © 2013 Elsevier Ltd. All rights reserved.
Chuang, Huan-Ming
2013-01-01
Ecological degradation is an escalating global threat. Increasingly, people are expressing awareness and priority for concerns about environmental problems surrounding them. Environmental protection issues are highlighted. An appropriate information technology tool, the growing popular social network system (virtual community, VC), facilitates public education and engagement with applications for existent problems effectively. Particularly, the exploration of related involvement behavior of VC member engagement is an interesting topic. Nevertheless, member engagement processes comprise interrelated sub-processes that reflect an interactive experience within VCs as well as the value co-creation model. To address the top-focused ecotourism VCs, this study presents an application of a hybrid expert-based ISM model and DEMATEL model based on multi-criteria decision making tools to investigate the complex multidimensional and dynamic nature of member engagement. Our research findings provide insightful managerial implications and suggest that the viral marketing of ecotourism protection is concerned with practitioners and academicians alike. PMID:24453902
A Molecular Dynamics Simulation of the Molten Ternary System (Li, K, Cs)Cl
NASA Astrophysics Data System (ADS)
Matsumiya, Masahiko; Takagi, Ryuzo
2000-12-01
The self-exchange velocity (SEV) of neighboring unlike ions, has been evaluated by molecular dynamics simulations of molten CsCl, (Li, K)C1 and (Li, K, Cs)Cl at 673 K. From the increase of the SEV's in the same order as the internal mobilities it is conjectured that there is a strong correlation between these two properties. The pair correlation functions, and the self-diffusion coefficients and the SEV's of Li+, K+, and Cs+ with reference to Cl- have also been calculated. The results allow to conclude that the self-exchange velocity of the cations become vCs < vK < vLi at xCs =0.1 and vLi < vK < vCs at xCs > 0.4. The sequence of the self-diffusion coefficients agrees with that of the SEV's. The results enable to conclude that it is possible to enrich Cs at up to xCs ~ 0.3 - 0.4 in the molten LiCl-KCl eutectic system.
Pulsatile flow in ventricular catheters for hydrocephalus
NASA Astrophysics Data System (ADS)
Giménez, Á.; Galarza, M.; Thomale, U.; Schuhmann, M. U.; Valero, J.; Amigó, J. M.
2017-05-01
The obstruction of ventricular catheters (VCs) is a major problem in the standard treatment of hydrocephalus, the flow pattern of the cerebrospinal fluid (CSF) being one important factor thereof. As a first approach to this problem, some of the authors studied previously the CSF flow through VCs under time-independent boundary conditions by means of computational fluid dynamics in three-dimensional models. This allowed us to derive a few basic principles which led to designs with improved flow patterns regarding the obstruction problem. However, the flow of the CSF has actually a pulsatile nature because of the heart beating and blood flow. To address this fact, here we extend our previous computational study to models with oscillatory boundary conditions. The new results will be compared with the results for constant flows and discussed. It turns out that the corrections due to the pulsatility of the CSF are quantitatively small, which reinforces our previous findings and conclusions. This article is part of the themed issue `Mathematical methods in medicine: neuroscience, cardiology and pathology'.
Study of virgin olive oil clarification by settling under dynamic conditions.
Gila, Abraham; Bejaoui, Mohamed Aymen; Beltrán, Gabriel; Aguilera, María Paz; Jiménez, Antonio
2018-04-16
Vertical centrifugation is the main method for virgin olive oil (VOO) clarification. However, in recent years, settling tanks are also being used to clarify the oils from decanters. They can operate under static or dynamic conditions. In this work, vertical centrifugation and settling under dynamic conditions for VOO clarification and their effects on VOO characteristics were compared. VOO quality parameters were not affected by the clarification systems studied. The vertical centrifugal separator (VCS) showed higher clarification efficiency, giving clarified oils with higher phenol content and better sensory characteristics. VOOs clarified by dynamic settling showed notable losses of phenols and worse sensory characteristics, since the tank purge system was not efficient, with most of the impurities remaining in the tanks. The VCS with minimal water addition is a quick operation with low water consumption and is a better option to produce VOOs of improved quality, especially in terms of longer shelf life and preservation of positive sensory notes. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.
Transport coefficients of Dirac ferromagnet: Effects of vertex corrections
NASA Astrophysics Data System (ADS)
Fujimoto, Junji
2018-03-01
As a strongly spin-orbit-coupled metallic model with ferromagnetism, we have considered an extended Stoner model to the relativistic regime, named Dirac ferromagnet in three dimensions. In a previous paper [J. Fujimoto and H. Kohno, Phys. Rev. B 90, 214418 (2014), 10.1103/PhysRevB.90.214418], we studied the transport properties giving rise to the anisotropic magnetoresistance (AMR) and the anomalous Hall effect (AHE) with the impurity potential being taken into account only as the self-energy. The effects of the vertex corrections (VCs) to AMR and AHE are reported in this paper. AMR is found not to change quantitatively when the VCs are considered, although the transport lifetime is different from the one-electron lifetime and the charge current includes additional contributions from the correlation with spin currents. The side-jump and the skew-scattering contributions to AHE are also calculated. The skew-scattering contribution is dominant in the clean case as can be seen in the spin Hall effect in the nonmagnetic Dirac electron system.
Chuang, Huan-Ming; Lin, Chien-Ku; Chen, Da-Ren; Chen, You-Shyang
2013-01-01
Ecological degradation is an escalating global threat. Increasingly, people are expressing awareness and priority for concerns about environmental problems surrounding them. Environmental protection issues are highlighted. An appropriate information technology tool, the growing popular social network system (virtual community, VC), facilitates public education and engagement with applications for existent problems effectively. Particularly, the exploration of related involvement behavior of VC member engagement is an interesting topic. Nevertheless, member engagement processes comprise interrelated sub-processes that reflect an interactive experience within VCs as well as the value co-creation model. To address the top-focused ecotourism VCs, this study presents an application of a hybrid expert-based ISM model and DEMATEL model based on multi-criteria decision making tools to investigate the complex multidimensional and dynamic nature of member engagement. Our research findings provide insightful managerial implications and suggest that the viral marketing of ecotourism protection is concerned with practitioners and academicians alike.
33 CFR 154.2180 - Alternative testing program-Generally.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Control Systems Alternative Analyzer and Pressure Sensor Reliability Testing § 154.2180 Alternative... and pressure sensor safety testing requirements provided by 33 CFR 154.2150(c) and 33 CFR 154.2250(c... 33 CFR 154.2181. (d) All pressure sensors/switches used in a VCS must be tested for safety system...
Sharma, P; Bhargava, M; Sukhachev, D; Datta, S; Wattal, C
2014-02-01
Tropical febrile illnesses such as malaria and dengue are challenging to differentiate clinically. Automated cellular indices from hematology analyzers may afford a preliminary rapid distinction. Blood count and VCS parameters from 114 malaria patients, 105 dengue patients, and 105 febrile controls without dengue or malaria were analyzed. Statistical discriminant functions were generated, and their diagnostic performances were assessed by ROC curve analysis. Three statistical functions were generated: (i) malaria-vs.-controls factor incorporating platelet count and standard deviations of lymphocyte volume and conductivity that identified malaria with 90.4% sensitivity, 88.6% specificity; (ii) dengue-vs.-controls factor incorporating platelet count, lymphocyte percentage and standard deviation of lymphocyte conductivity that identified dengue with 81.0% sensitivity and 77.1% specificity; and (iii) febrile-controls-vs.-malaria/dengue factor incorporating mean corpuscular hemoglobin concentration, neutrophil percentage, mean lymphocyte and monocyte volumes, and standard deviation of monocyte volume that distinguished malaria and dengue from other febrile illnesses with 85.1% sensitivity and 91.4% specificity. Leukocyte abnormalities quantitated by automated analyzers successfully identified malaria and dengue and distinguished them from other fevers. These economic discriminant functions can be rapidly calculated by analyzer software programs to generate electronic flags to trigger-specific testing. They could potentially transform diagnostic approaches to tropical febrile illnesses in cost-constrained settings. © 2013 John Wiley & Sons Ltd.
Detecting Nonadditivity in Single-Facet Generalizability Theory Applications: Tukey's Test
ERIC Educational Resources Information Center
Lin, Chih-Kai; Zhang, Jinming
2018-01-01
Under the generalizability-theory (G-theory) framework, the estimation precision of variance components (VCs) is of significant importance in that they serve as the foundation of estimating reliability. Zhang and Lin advanced the discussion of nonadditivity in data from a theoretical perspective and showed the adverse effects of nonadditivity on…
The Burdens of Visual Culture Studies
ERIC Educational Resources Information Center
Bauerlein, Mark
2004-01-01
In arts education, Visual Culture Studies (VCS) is currently at its height, and proponents of it act with all the verve of partisans on a roll. A little knowledge of history, however, should curb their enthusiasm. Academia has a way of assimilating the most extreme theories and pursuits into standard operating procedure, and the evanescence of…
The InVEST Volcanic Concept Survey: Exploring Student Understanding about Volcanoes
ERIC Educational Resources Information Center
Parham, Thomas L., Jr.; Cervato, Cinzia; Gallus, William A., Jr.; Larsen, Michael; Hobbs, Jon; Stelling, Pete; Greenbowe, Thomas; Gupta, Tanya; Knox, John A.; Gill, Thomas E.
2010-01-01
Results from the Volcanic Concept Survey (VCS) indicated that many undergraduates do not fully understand volcanic systems and plate tectonics. During the 2006 academic year, a ten-item conceptual survey was distributed to undergraduate students enrolled in Earth science courses at five U.S. colleges and universities. A trained team of graders…
46 CFR 39.1001 - Applicability-TB/ALL.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 1 2014-10-01 2014-10-01 false Applicability-TB/ALL. 39.1001 Section 39.1001 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS VAPOR CONTROL SYSTEMS General § 39.1001 Applicability—TB/ALL. (a) This part applies to tank vessels that use a vapor control system (VCS) to collect...
46 CFR 39.1001 - Applicability-TB/ALL.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 1 2013-10-01 2013-10-01 false Applicability-TB/ALL. 39.1001 Section 39.1001 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS VAPOR CONTROL SYSTEMS General § 39.1001 Applicability—TB/ALL. (a) This part applies to tank vessels that use a vapor control system (VCS) to collect...
ERIC Educational Resources Information Center
Shen, Kathy Ning; Yu, Angela Yan; Khalifa, Mohamed
2010-01-01
Integrating social presence theory and social identity theory, this study brings system design and social influence aspects together to explain their joint effects on knowledge contribution in virtual communities (VCs). Different from most prior information systems (IS) research that adopts a uni-dimensional approach and restricts social presence…
Who Decides Higher Education Policy? MPS, VCS, STEM and HASS
ERIC Educational Resources Information Center
Tight, Malcolm
2012-01-01
In the UK, and in many other countries, policy makers and funding bodies emphasise the importance of the STEM disciplines (science, technology, engineering and mathematics), as opposed to the HASS disciplines (humanities, arts and social sciences), in higher education. Yet an examination of the biographies of UK members of parliament (MPs)…
Effects of vasoactive intestinal peptide on vascular conductance are unaffected by anesthesia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bouder, T.G.; Huffman, L.J.; Hedge, G.A.
1988-12-01
In rats anesthetized with ketamine and pentobarbital (KET/PB), vasoactive intestinal peptide (VIP) increases vascular conductance (VC) in the salivary gland, pancreas, and thyroid gland, whereas no changes in VC are observed in a number of other organs. Because anesthesia may alter the responsiveness of physiological systems, we compared the effects of VIP on organ VC in conscious or anesthetized rats. Chronically catheterized rats were studied in the conscious state or 30 min after induction of anesthesia with KET/PB, isoflurane, or Inactin. Blood flows were measured by the reference sample version of the radioactive microsphere (MS) technique using two MS injectionsmore » ({sup 141}Ce-MS/{sup 85}Sr-MS). Mean arterial blood pressure was monitored and used in the calculation of VC. Organ VCs were similar under basal conditions in conscious and anesthetized rats. VIP infusion caused systemic hypotension and increased VCs in the salivary gland, pancreas, and thyroid gland, and these responses were largely unaffected by anesthesia. These results indicate that the anesthetics used do not alter basal VC or the responsiveness of the vasculature to exogenous VIP.« less
The virtual case: a new method to completely digitize cytological and histological slides.
Demichelis, F; Barbareschi, M; Dalla Palma, P; Forti, S
2002-08-01
The purpose of this study was to present a new method for handling histological/cytological cases. Thanks to the introduction of information technology in pathology, including the amenities afforded by robotic microscopes and digital imaging, tissue slides can be represented and evaluated using digital techniques in order to construct virtual cases through completely automated procedures. A virtual case (VC) is composed of a collection of digital images representing a histological/cytological slide at all magnification levels together with all relevant clinical data. In the present study, we describe an automated system to manage robotic microscope and image acquisition for the proper construction of VCs. These can then be viewed on a computer by means of an interface ("user-friendly") that allows one to select the more appropriate fields and to examine them at different magnifications, rapidly going from panoramic views to high resolution and vice versa. In comparison with glass slides, VCs have several advantages arising from their digital nature and can be considered a common platform for a wide range of applications such as teleconsultation, education, research, and quality control and proficiency tests.
2010-01-01
Background The notion 'hard to reach' is a contested and ambiguous term that is commonly used within the spheres of social care and health, especially in discourse around health and social inequalities. There is a need to address health inequalities and to engage in services the marginalized and socially excluded sectors of society. Methods This paper describes a pilot study involving interviews with representatives from eight Voluntary and Community Sector (VCS) organisations. The purpose of the study was to explore the notion of 'hard to reach' and perceptions of the barriers and facilitators to accessing services for 'hard to reach' groups from a voluntary and community sector perspective. Results The 'hard to reach' may include drug users, people living with HIV, people from sexual minority communities, asylum seekers, refugees, people from black and ethnic minority communities, and homeless people although defining the notion of the 'hard to reach' is not straight forward. It may be that certain groups resist engaging in treatment services and are deemed hard to reach by a particular service or from a societal stance. There are a number of potential barriers for people who may try and access services, including people having bad experiences in the past; location and opening times of services and how services are funded and managed. A number of areas of commonality are found in terms of how access to services for 'hard to reach' individuals and groups could be improved including: respectful treatment of service users, establishing trust with service users, offering service flexibility, partnership working with other organisations and harnessing service user involvement. Conclusions If health services are to engage with groups that are deemed 'hard to reach' and marginalised from mainstream health services, the experiences and practices for engagement from within the VCS may serve as useful lessons for service improvement for statutory health services. PMID:20377850
78 FR 44265 - Unified Agenda of Federal Regulatory and Deregulatory Actions
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-23
... . RIN: 1625-AB27 184. Marine Vapor Control Systems Legal Authority: 33 U.S.C. 1225; 42 U.S.C. 7511b(f)(2... facility and vessel vapor control systems (VCSs). The proposed changes would make VCS requirements more... Requirements for 1625-AA99 Notices of Arrival and Departure, and Automatic Identification System. 182...
The Gendered Shaping of University Leadership in Australia, South Africa and the United Kingdom
ERIC Educational Resources Information Center
White, Kate; Bagilhole, Barbara; Riordan, Sarah
2012-01-01
This article analyses career trajectories into university management in Australia, South Africa and the United Kingdom (UK), skills required to operate effectively and the power of vice-chancellors (VCs) and their impact on the gendered shaping of university leadership. It is based on qualitative research with 56 male and female senior managers.…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-28
... the airplane weight and balance. This proposed AD was prompted by reports of damage around the VCS... balance. Authority for This Rulemaking Title 49 of the United States Code specifies the FAA's authority to... weight and balance. Special Flight Permit (h) The compressor drive belt must be cut and removed before...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-11
... Regulatory Review B. Paperwork Reduction Act C. Regulatory Flexibility Act D. Unfunded Mandates Reform Act E... preamble. APA Administrative Procedure Act CAA Clean Air Act CFR Code of Federal Regulations D.C. District... Authority Rule U.S. United States U.S.C. United States Code VCS Voluntary Consensus Standards VOC Volatile...
STS-41 Voice Command System Flight Experiment Report
NASA Technical Reports Server (NTRS)
Salazar, George A.
1981-01-01
This report presents the results of the Voice Command System (VCS) flight experiment on the five-day STS-41 mission. Two mission specialists,Bill Shepherd and Bruce Melnick, used the speaker-dependent system to evaluate the operational effectiveness of using voice to control a spacecraft system. In addition, data was gathered to analyze the effects of microgravity on speech recognition performance.
ERIC Educational Resources Information Center
Hsieh, Sheng-Wen; Wu, Min-Ping
2013-01-01
This paper used a Virtual Companion System (VCS) to examine how specific design variables within virtual learning companion affect the learning process of learners as defined by the cognitive continuum of field-dependent, field-independent and field-mixed learners in LINE app for m-learning. The data were collected from 198 participants in a…
2015-02-01
Centralization . . . . . . . . . . . . . . . . . . . . . . 43 “Anonymity”: A Bitcoin Case Study...been a case of x National Security Implications of Virtual Currency such a non-state actor deployment; in this report, we aim to high- light...development of VCs may advance, including a gen- eral increased sophistication in cryptographic applications. More gen- erally, we make the case that the main
Teachers' Views on Co-Education: Co-Education or Single-Sex Education?
ERIC Educational Resources Information Center
Sari, Mediha
2017-01-01
The purpose of this study is to investigate teachers' views on co-education. The study, which adopted a descriptive screening model, involved 240 teachers (142 females and 84 males) working in four primary schools and four secondary schools located in the central towns of Adana. Data were collected using Views on Co-education Scale (VCS). Analysis…
Female rats express a conditioned object preference for receipt of sexual stimulation.
Guterl, Sophie A; McNamara, Tanner A; Klumpp, Gracie C; Meerts, Sarah H
2015-11-01
Female rats alternately approach and avoid the male rat during copulation, potentially reflecting appetitive and aversive aspects of mating, respectively. We developed a novel classical conditioning procedure, conditioned object preference (COP), to test whether female rats show increased approach toward a conditioned stimulus associated directly with receipt of sexual stimulation. During conditioning, one scented object was paired with an appetitive stimulus and a different object plus scent was paired with a control stimulus on a separate day. After conditioning, preference for each object was evaluated with a choice task. Experiment 1 was conducted to verify the procedure. Rats exhibited a significant COP for 1mg/kg amphetamine, indicating that the conditioned object preference procedure is an effective tool for evaluating the rewarding nature of a treatment. In Experiment 2, paced mating to one ejaculation and experimenter-delivered artificial vaginocervical stimulation (aVCS) each induced a COP. The robust COPs for paced mating and aVCS support the notion that female rats experience a reward state during receipt of sexual stimulation. Moreover, the data suggest that any aversive aspects of receipt of sexual stimulation do not overshadow the appetitive effects. Copyright © 2015 Elsevier Inc. All rights reserved.
Representation of the five- and six-dimensional harmonic oscillators in a u(5) ⊃ so(5) ⊃ so(3) basis
NASA Astrophysics Data System (ADS)
Rowe, D. J.
1994-06-01
The duality that exists between the two subgroups SU(1,1) and O(5) of Sp(5,R) to construct basis states for the five-dimensional harmonic oscillator which simultaneously reduce the Sp(5,R)⊇U(5)⊇O(5)⊇SO(3) and Sp(5,R)⊇ SU(1,1)⊇U(1) subgroup chains is used. It is shown that the vector-coherent-state wave functions of the fundamental five-dimensional SO(5) irrep [1,0] realize the traceless bosons introduced by Lohe and Hurst to classify the irreps of the orthogonal groups and employed in Chacon, Moshinsky, and Sharp's construction of a basis for the five-dimensional harmonic oscillator. Moreover, it is shown that VCS theory provides a simple mechanism for constructing matrix elements of the traceless boson operators. These matrix elements are used to extend the VCS representations of SO(5) in an SO(3) basis, given in a previous paper, to irreps of U(5) in an SO(5)⊇ SO(3) basis. The extension to U(6)⊇U(5)⊇SO(5)⊇SO(3) is also given.
Couto, Maria Claudia Lima; Lange, Liséte Celina; Rosa, Rodrigo de Alvarenga; Couto, Paula Rogeria Lima
2017-12-01
The implementation of reverse logistics systems (RLS) for post-consumer products provides environmental and economic benefits, since it increases recycling potential. However, RLS implantation and consolidation still face problems. The main shortcomings are the high costs and the low expectation of broad implementation worldwide. This paper presents two mathematical models to decide the number and the location of screening centers (SCs) and valorization centers (VCs) to implement reverse logistics of post-consumer packages, defining the optimum territorial arrangements (OTAs), allowing the inclusion of small and medium size municipalities. The paper aims to fill a gap in the literature on RLS location facilities that not only aim at revenue optimization, but also the participation of the population, the involvement of pickers and the service universalization. The results showed that implementation of VCs can lead to revenue/cost ratio higher than 100%. The results of this study can supply companies and government agencies with a global view on the parameters that influence RLS sustainability and help them make decisions about the location of these facilities and the best reverse flows with the social inclusion of pickers and serving the population of small and medium-sized municipalities.
Mandolesi, Sandro; Niglio, Tarcisio; Orsini, Augusto; De Sio, Simone; d'Alessandro, Alessandro; Mandolesi, Dimitri; Fedele, Francesco; d'Alessandro, Aldo
2016-01-01
Analysis of the incidence of Venous Compression Syndrome (VCS) with full block of the flow of the internal jugular veins (IJVs) in patients with Multiple Sclerosis and Chronic cerebro-spinal venous insufficiency. We included 769 patients with MS and CCSVI (299 males, 470 females) and 210 controls without ms and ccsvi (92 males, 118 females). each subject was investigated by echo-color-doppler (ecd). morphological and hemodynamic ecd data were recorded by a computerized mem-net maps of epidemiological national observatory on ccsvi and they were analyzed by mem-net clinical analysis programs. VCS of IJVs occurs in 240 subjects affected by CCSVI and MS (31% of total) and in 12 controls (6% of total). The differences between the two groups are statistical significant (X² = 36.64, p<0.0001). Up to day there are no longitudinal studies that allow us to identify the WC of jugular and/or vertebral veins as etiology of a chronic neurodegenerative disease, but we note that Venous Compression Syndrome of IJVs is strongly associated with MS and CCSVI. Chronic Cerebro-Spinal Venous Insufficiency, Multiple Sclerosis, Venous Compression Syndrome.
Self-assembly of Carbon Vacancies in Sub-stoichiometric ZrC1−x
Zhang, Yanhui; Liu, Bin; Wang, Jingyang
2015-01-01
Sub-stoichiometric interstitial compounds, including binary transition metal carbides (MC1−x), maintain structural stability even if they accommodate abundant anion vacancies. This unique character endows them with variable-composition, diverse-configuration and controllable-performance through composition and structure design. Herein, the evolution of carbon vacancy (VC) configuration in sub-stoichiometric ZrC1−x is investigated by combining the cluster expansion method and first-principles calculations. We report the interesting self-assembly of VCs and the fingerprint VC configuration (VC triplet constructed by 3rd nearest neighboring vacancies) in all the low energy structures of ZrC1−x. When VC concentration is higher than the critical value of 0.5 (x > 0.5), the 2nd nearest neighboring VC configurations with strongly repulsive interaction inevitably appear, and meanwhile, the system energy (or formation enthalpy) of ZrC1−x increases sharply which suggests the material may lose phase stability. The present results clarify why ZrC1−x bears a huge amount of VCs, tends towards VC ordering, and retains stability up to a stoichiometry of x = 0.5. PMID:26667083
Jing Cai; Melvin T. Tyree
2010-01-01
The objective of this study was to quantify the relationship between vulnerability to cavitation and vessel diameter within a species. We measured vulnerability curves (VCs: percentage loss hydraulic conductivity versus tension) in aspen stems and measured vessel-size distributions. Measurements were done on seed-grown, 4-month-old aspen (Populus tremuloides...
Viral impacts on microbial carbon cycling in thawing permafrost soils
NASA Astrophysics Data System (ADS)
Trubl, G. G.; Roux, S.; Bolduc, B.; Jang, H. B.; Emerson, J. B.; Solonenko, N.; Li, F.; Solden, L. M.; Vik, D. R.; Wrighton, K. C.; Saleska, S. R.; Sullivan, M. B.; Rich, V. I.
2017-12-01
Permafrost contains 30-50% of global soil carbon (C) and is rapidly thawing. While the fate of this C is unknown, it will be shaped in part by microbes and their associated viruses, which modulate host activities via mortality and metabolic control. To date, viral research in soils has been outpaced by that in aquatic environments, due to the technical challenges of accessing viruses as well as the dramatic physicochemical heterogeneity in soils. Here, we describe advances in soil viromics from our research on permafrost-associated soils, and their implications for associated terrestrial C cycling. First, we optimized viral resuspension-DNA extraction methods for a range of soil types. Second, we applied cutting-edge viral-specific informatics methods to recover viral populations, define their gene content, connect them to potential hosts, and analyze their relationships to environmental parameters. A total of 781 viral populations were recovered from size-fractionated virus samples of three soils along a permafrost thaw gradient. Ecological analyses revealed endemism as recovered viral populations were largely unique to each habitat and unlike those in aquatic communities. Genome- and network-based classification assigned these viruses into 226 viral clusters (VCs; genus-level taxonomy), 55% of which were novel. This increases the number of VCs by a third and triples the number of soil viral populations in the RefSeq database (currently contains 256 VCs and 316 soil viral populations). Genomic analyses revealed 85% of the genes were functionally unknown, though 5% of the annotatable genes contained C-related auxiliary metabolic genes (AMGs; e.g. glycoside hydrolases). Using sequence-based features and microbial population genomes, we were able to in silico predict hosts for 30% of the viral populations. The identified hosts spanned 3 phyla and 6 genera but suggested these viruses have species-specific host ranges as >80% of hosts for a given virus were in the same species. Several identified hosts (e.g. Acidobacterium) are dominant community members that play major roles in C cycling through organic matter degradation. Together these findings show that permafrost viruses play a major role in the fate of soil C through infection of key hosts and metabolic reprogramming using specific C cycling AMGs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McIntosh, Gordon; Indermuehle, Balthasar, E-mail: mcintogc@morris.umn.edu, E-mail: balt.indermuehle@csiro.au
We present an analysis of velocity parameters derived from multi-epoch observations of the SiO maser spectra of 47 long period variables (LPVs). The velocity parameters are important to inform and constrain theoretical models of SiO maser emission and to extract information on binary orbits. Mira and R Aquarii (R Aqr) are two known binaries included in the program. The 47 LPVs are among 121 sources of the Australia Telescope National Facility Mopra telescope's monitoring program. Observations were carried out several times a year between 2008 and 2012 and are continuing. The SiO spectra are from the v = 1, Jmore » = 1-0 (43.122 GHz; hereafter J10) and the v = 1, J = 2-1 (86.2434 GHz; hereafter J21) transitions. For 41 of the 47 LPVs we observed both transitions nearly simultaneously in 457 observations. We have determined and compared the velocity centroids (VCs) and velocity ranges (VRs) of emission suffixed as above (10 and 21) for the two transitions: VC10, VC21, VR10, and VR21. The VCs of the two transitions are, on average, within 0.13 km s{sup -1} of each other but are sometimes separated by a few km s{sup -1}. The VC10s are, on average, slightly more positive than the VC21s. The values of the VCs in the two transitions have been compared to justify using both of these transitions to extract binary star orbital parameters. The arithmetic mean VR10 derived from 635 observations of 47 sources is 6.4 km s{sup -1} with a standard deviation of 3.4 km s{sup -1}, while the mean VR21 derived from 485 observations of 41 sources is 4.2 km s{sup -1} with a standard deviation of 2.8 km s{sup -1}. The number of occurrences of VR10 and VR21 versus VR have different distributions. The differences in the VRs indicate that the J21 and J10 emissions arise from dynamically different regions of the circumstellar environment.« less
Chen, Mingsheng; Qian, Dongfu; Feng, Zhanchun; Si, Lei
2018-01-01
Objectives Government healthcare subsidies for healthcare facilities play a significant role in providing more extensive healthcare access to patients, especially poor ones. However, equitable distribution of these subsidies continues to pose a challenge in rural ethnic minority areas of China. This study aimed to evaluate the benefits distribution of outpatient services across different socioeconomic populations in China’s rural ethnic minority areas. Setting Inner Mongolia Autonomous Region, Xinjiang Autonomous Region and Qinghai Province. Design Two rounds of cross-sectional study. Participants One thousand and seventy patients in 2010 and 907 patients in 2013, who sought outpatient services prior to completing the household surveys, were interviewed. Methods Benefits incidence analysis was performed to measure the benefits distribution of government healthcare subsidies across socioeconomic groups. The concentration index (CI) for outpatient care at different healthcare facility levels in rural ethnic minority areas was calculated. Two rounds of household surveys using multistage stratified samples were conducted. Findings The overall CI for outpatient care was –0.0146 (P>0.05) in 2010 and –0.0992 (P<0.01) in 2013. In 2010, the CI was –0.0537 (P<0.01), –0.0085 (P>0.05) and −0.0034 (P>0.05) at levels of village clinics (VCs), township health centres (THCs) and county hospitals (CHs), respectively. In 2013, the CI was –0.1353 (P<0.05), –0.0695 (P>0.05) and –0.1633 (P<0.01) at the levels of VCs, THCs and CHs, respectively. Conclusion Implementation of the gatekeeper mechanism helped improve the benefits distribution of government healthcare subsidies in rural Chinese ethnic minority areas. Equitable distribution of government healthcare subsidies for VCs was improved by increasing financial input and ensuring the performance of primary healthcare facilities. Equitable distribution of subsidies for CHs was improved by policies that rationally guided patients’ care-seeking behaviour. In addition, highly qualified physicians were also a key factor in ensuring equitable benefits distribution. PMID:29431138
NASA Astrophysics Data System (ADS)
Mrad, A.; Domec, J. C.; Huang, C. W.; Katul, G. G.
2017-12-01
Xylem tissues are specialized in offering the least possible resistance to water flow. However, this is not guaranteed when ascending sap reaches large negative pressures during periods of water stress when embolism within the xylem occurs, an inevitable step toward potential drought-induced mortality. Ongoing research into changing forest patterns and plant survival due to droughts rarely dispute the significance of Vulnerability Curves (VCs), plots that feature loss in relative conductance with declining liquid pressure (ψ). While Earth-Systems models routinely employ various VC functions, the theoretical underpinnings describing their shape remains lacking. VCs are the outcome of microscopic phenomena describing embolism formation, bubble-scale xylem properties allowing embolism spread, and hydraulic processes that dictate the water potential along the flow path. The work here explores how the upscaled version of these gives rise to popular mathematical shapes used to describe VC measurements: The Logistic and Weibull exceedance equations. Each of these two captures a distinct type of embolism spread: The Logistic VC arises when the probability that embolized vessels interact with intact ones describe embolism spread as water pressure decreases (labeled as a similarity law in botanic [1]). The Weibull VC arises when the aforementioned description includes the effects of ψ explicitly. Variability in xylem properties along the flow path is explored analytically using novel approaches borrowed from `super-statistics' and numerical simulations. The numerical simulations intend to single out which xylem network property is significant in describing the VC shape. The model results corroborate previous research (experimental and 3-dimensional high-resolution simulations) on the effect of vessel size and network topology. It is shown that (i) initial embolism locations alter air-seeding pressure and VC slope; (ii) redundancy and size variations decrease bubble propagation probability with decreasing ψ; and (iii) varying network properties spatially along the flow path delays total loss of conductance. The implications of these findings to linking VC shape to plant traits and the on-going debate about `r' vs `s' shape VCs are highlighted.
Darroudi, F; Meijers, C M; Hadjidekova, V; Natarajan, A T
1996-09-01
In human hepatoma (Hep G2) cells and peripheral blood lymphocytes (HPBL) the cytokinesis-blocked micronuclei (MN) and fluorescent in situ hybridization (FISH) assays were applied to study aneugenic and clastogenic potentials of X-rays, directly and indirectly acting chemicals. Induction of MN was studied in vitro following treatment with X-rays, directly acting chemicals, such as methylmeth-anesulphonate (MMS), colchicine (COL), vincristine sulphate (VCS) and vinblastine sulphate (VBS), and indirectly acting agents, such as cyclophosphamide (CP), hexamethylphosphoramide (HMPA), 2-acetylaminofluorene (2-AAF) and 4-acetylaminofluorene (4-AAF). Depending on the presence of the fluorescent signal in the MN following FISH with a human DNA centromeric probe, MN in the binucleated Hep G2 cells and lymphocytes were scored as centromere-positive or centromere-negative, representing an aneugenic and clastogenic event respectively. In the controls approximately 50% of spontaneously occurring MN were centromere-positive. Treatment of human hepatoma cells and HPBL (in vitro) with potent aneugens such as COL, VCS and VBS increased the number of MN in a dose-dependent manner; of these 75-93% were centromere-positive. X-irradiation induced MN in a dose-related manner in binucleated Hep G2 cells and HPBL, of which 33-40% were centromere-positive, which demonstrates the significant aneugenic potentials of X-rays. Strong clastogenic activity was observed with MMS and frequency of centromere-positive MN was low: approximately 20 and 30% for HPBL and Hep G2 cells respectively. In Hep G2 cells significant aneugenic activity was found with indirectly acting promutagens/procarcinogens such as HMPA and 2-AAF, in contrast to CP, which came out as a potent clastogen. The non-carcinogen 4-AAF was not able to induce an increase in the frequency of MN in Hep G2 cells. All indirectly acting chemicals tested came out negative when HPBL were used as targets for DNA damage. The results presented correlate positively with data from in vivo assays and indicate that the Hep G2 cell system is a suitable bioactivation system (in vitro) for evaluating the clastogenic and aneugenic potentials of chemicals which require exogenous metabolic activations in order to exert their mutagenic potential.
Science highlights from high-sensitivity pulsar observations with the MWA
NASA Astrophysics Data System (ADS)
McSweeney, Samuel; Bhat, Ramesh; Tremblay, Steven; Ord, Stephen
2016-01-01
Pulsars are exquisite probes of the turbulent interstellar medium (ISM), capable of resolving structures down to tens of thousands of kilometres. Understanding the ISM is important for many areas of astrophysics, such as galactic dynamics, the chemical evolution of the galaxy, and the identification of timing noise in the search for gravitational waves using pulsar timing arrays. Low frequency observations of pulsars are key, because the strength of propagation effects scales strongly with frequency.We present the Murchison Widefield Array (MWA) as a key science tool for making high quality observations of pulsars at low frequencies (~80-300 MHz). Recently commissioned software for making tied-array beams and the MWA's high time resolution voltage capture system (VCS) allow an order of magnitude increase in sensitivity, vital for pulsar and other time-domain science. A pipeline has now been developed for observing the scintillation patterns of important pulsars at low frequencies, including a new computational technique for measuring the curvature of parabolic arcs in noisy secondary spectra. A program of MWA observations is being undertaken to sample a large number of millisecond pulsars. We present recent highlights including PSR J0437-4715, which yielded a new measurement of scattering screen distance of ~120 pc from Earth, consistent with a Parkes observation at ~730 MHz, and matching the predicted perimeter of the Local Bubble.
Students' Strategies in Response to Teachers' Second Language Explanations of Lexical Items
ERIC Educational Resources Information Center
Macaro, Ernesto
2017-01-01
This study of vocabulary comprehension strategies (VCS) is framed by the debate on L2-only instruction in the second or foreign language (L2) classroom where the teacher shares the first language (L1) of the students. Research has shown that some teachers switch to the L1 to explain lexical items while others try to explain them through L2…
Gun Control for VBE-E: User Guide and Technical Description
2006-11-01
Defence R& D Canada – Atlantic DEFENCE DÉFENSE & Gun Control for VBE-E User Guide and Technical Description Tania E. Wentzell Technical Memorandum...Defence R& D Canada – Atlantic Technical Memorandum DRDC Atlantic TM 2006-245 November 2006 DRDC Atlantic TM 2006-245...component of the distributed experimentation environment used by the Virtual Combat System (VCS) Group at Defence R& D Canada – Atlantic (DRDC Atlantic
Cai, Jing; Li, Shan; Zhang, Haixin; Zhang, Shuoxin; Tyree, Melvin T
2014-01-01
Vulnerability curves (VCs) generally can be fitted to the Weibull equation; however, a growing number of VCs appear to be recalcitrant, that is, deviate from a Weibull but seem to fit dual Weibull curves. We hypothesize that dual Weibull curves in Hippophae rhamnoides L. are due to different vessel diameter classes, inter-vessel hydraulic connections or vessels versus fibre tracheids. We used dye staining techniques, hydraulic measurements and quantitative anatomy measurements to test these hypotheses. The fibres contribute 1.3% of the total stem conductivity, which eliminates the hypothesis that fibre tracheids account for the second Weibull curve. Nevertheless, the staining pattern of vessels and fibre tracheids suggested that fibres might function as a hydraulic bridge between adjacent vessels. We also argue that fibre bridges are safer than vessel-to-vessel pits and put forward the concept as a new paradigm. Hence, we tentatively propose that the first Weibull curve may be accounted by vessels connected to each other directly by pit fields, while the second Weibull curve is associated with vessels that are connected almost exclusively by fibre bridges. Further research is needed to test the concept of fibre bridge safety in species that have recalcitrant or normal Weibull curves. © 2013 John Wiley & Sons Ltd.
Solid waste management of temple floral offerings by vermicomposting using Eisenia fetida
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singh, Akanksha, E-mail: bhuaks29@gmail.com; Jain, Akansha, E-mail: akansha007@rediffmail.com; Sarma, Birinchi K., E-mail: birinchi_ks@yahoo.com
2013-05-15
Highlights: ► Effective management of temple floral offerings using E. fetida. ► Physico-chemical properties in TW VC were better especially EC, C/N, C/P and TK. ► TW VC as plant growth promoter at much lower application rates than KW and FYW VC. - Abstract: Recycling of temple waste (TW) mainly comprising of floral offerings was done through vermitechnology using Eisenia fetida and its impact on seed germination and plant growth parameters was studied by comparing with kitchen waste (KW) and farmyard waste (FYW) vermicompost (VC). The worm biomass was found to be maximum in TW VC compared to KW andmore » FYW VCs at both 40 and 120 days old VCs. Physico-chemical analysis of worm-worked substrates showed better results in TW VC especially in terms of electrical conductivity, C/N, C/P and TK. 10% TW VC–water extract (VCE) showed stimulatory effect on germination percentage of chickpea seeds while KW and FYW VCE proved effective at higher concentration. Variation in growth parameters was also observed with change in the VC–soil ratio and TW VC showed enhanced shoot length, root length, number of secondary roots and total biomass at 12.5% VC compared to KW and FYW VC.« less
Nakamura, Toshimichi; Toshimoto, Kota; Lee, Wooin; Imamura, Chiyo K; Tanigawara, Yusuke; Sugiyama, Yuichi
2018-06-19
The Tamoxifen Response by CYP2D6 Genotype-based Treatment-1 (TARGET-1) study (n = 180) was conducted from 2012-2017 in Japan to determine the efficacy of tamoxifen dosing guided by cytochrome P450 2D6 (CYP2D6) genotypes. To predict its outcomes prior to completion, we constructed the comprehensive physiologically based pharmacokinetic (PBPK) models of tamoxifen and its metabolites and performed virtual TARGET-1 studies. Our analyses indicated that the expected probability to achieve the end point (demonstrating the superior efficacy of the escalated tamoxifen dose over the standard dose in patients carrying CYP2D6 variants) was 0.469 on average. As the population size of this virtual clinical study (VCS) increased, the expected probability was substantially increased (0.674 for n = 260). Our analyses also informed that the probability to achieve the end point in the TARGET-1 study was negatively impacted by a large variability in endoxifen levels. Our current efforts demonstrate the promising utility of the PBPK modeling and VCS approaches in prospectively designing effective clinical trials. © 2018 The Authors CPT: Pharmacometrics & Systems Pharmacology published by Wiley Periodicals, Inc. on behalf of American Society for Clinical Pharmacology and Therapeutics.
Gain, noise, and contrast sensitivity of linear visual neurons
NASA Technical Reports Server (NTRS)
Watson, Andrew B.
1990-01-01
Contrast sensitivity is a measure of the ability of an observer to detect contrast signals of particular spatial and temporal frequencies. A formal definition of contrast sensitivity that can be applied to individual linear visual neurons is derived. A neuron is modeled by a contrast transfer function and its modulus, contrast gain, and by a noise power spectrum. The distributions of neural responses to signal and blank presentations are derived, and from these, a definition of contrast sensitivity is obtained. This formal definition may be used to relate the sensitivities of various populations of neurons, and to relate the sensitivities of neurons to that of the behaving animal.
Rural Health, Center of Excellence for Remote and Medically Under-served Area (CERMUSA)
2007-05-01
Pretest I Posttest of Cognitive Knowledge, • Pretest I Posttest of Knowledge (Self Perception), • VCS Feature Comparison. Pretest I Posttest of Cognitive...This measurement was the change between the pretest and posttest scores. Figure 6 represents the average pretest , posttest , and difference scores for...to the educational intervention, each case student’s average posttest scores increased over the pretest scores. Also, in each case, the
Liu, Xiao-wei; Pang, Guo-xiang; Liu, Xi-pu; Jiang, Ru-xin; Jin, Yu-mei; Sun, Yu-min; Wang, Zhong-hai
2003-10-01
To evaluate the static and dynamic contrast sensitivity changes in myopic patients before and after laser in situ keratomileusis (LASIK). Seventy-three eyes in 37 patients with myopia (with or without astigmatism) who received LASIK were tested for static and dynamic contrast sensitivities using the METRO VISION MON ELEC I system at 0.7, 1.4, 2.7, 5.5, 11, and 22 cpd and cps prior to LASIK, and at one-, three-, and six-month intervals after LASIK. All eyes gained naked visual acuity of more than 0.5 after LASIK. The contrast sensitivity was depressed at all frequencies 1 month after LASIK, as compared to one week prior to LASIK. The depression at 2.7, 5.5, 11 (P < 0.01) and 22 cpd (P < 0.05) was statistically significant for static contrast sensitivity, and also at 5.5 (P < 0.01) and 11 cps (P < 0.05) for dynamic contrast sensitivity. Myopic eyes between 6.25 D and 14.0 D, and astigmatic eyes 2 DC and more, suffered more static and dynamic contrast sensitivity depression than the myopic eyes between 1.25 D and 6.00 D and astigmatic eyes less than 2 DC. Contrast sensitivities were improved and exceeded preoperative levels 3 months after LASIK, and improved even more 6 months after LASIK. All sequences were statistically significant for static contrast sensitivity (P < 0.01), while only 2.7, 5.5, and 11 cps were statistically significant for dynamic contrast sensitivity (P < 0.01). The astigmatic eyes 2 DC and more showed less improvement, even below the preoperative level at 1.4 cps of dynamic contrast sensitivity. While temporary depression of contrast sensitivity for myopic eyes after LASIK was seen, contrast sensitivity soon returned to exceed preoperative levels at 3 months after LASIK, while improving even more 6 months after LASIK.
L3.PHI.CTF.P10.02-rev2 Coupling of Subchannel T/H (CTF) and CRUD Chemistry (MAMBA1D)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Salko, Robert K.; Palmtag, Scott; Collins, Benjamin S.
2015-05-15
The purpose of this milestone is to create a preliminary capability for modeling light water reactor (LWR) thermal-hydraulic (T/H) and CRUD growth using the CTF subchannel code and the subgrid version of the MAMBA CRUD chemistry code, MAMBA1D. In part, this is a follow-on to Milestone L3.PHI.VCS.P9.01, which is documented in Report CASL-U-2014-0188-000, titled "Development of CTF Capability for Modeling Reactor Operating Cycles with Crud Growth". As the title suggests, the previous milestone set up a framework for modeling reactor operation cycles with CTF. The framework also facilitated coupling to a CRUD chemistry capability for modeling CRUD growth throughout themore » reactor operating cycle. To demonstrate the capability, a simple CRUD \\surrogate" tool was developed and coupled to CTF; however, it was noted that CRUD growth predictions by the surrogate were not considered realistic. This milestone builds on L3.PHI.VCS.P9.01 by replacing this simple surrogate tool with the more advanced MAMBA1D CRUD chemistry code. Completing this task involves addressing unresolved tasks from Milestone L3.PHI.VCS.P9.01, setting up an interface to MAMBA1D, and extracting new T/H information from CTF that was not previously required in the simple surrogate tool. Speci c challenges encountered during this milestone include (1) treatment of the CRUD erosion model, which requires local turbulent kinetic energy (TKE) (a value that CTF does not calculate) and (2) treatment of the MAMBA1D CRUD chimney boiling model in the CTF rod heat transfer solution. To demonstrate this new T/H, CRUD modeling capability, two sets of simulations were performed: (1) an 18 month cycle simulation of a quarter symmetry model of Watts Bar and (2) a simulation of Assemblies G69 and G70 from Seabrook Cycle 5. The Watts Bar simulation is merely a demonstration of the capability. The simulation of the Seabrook cycle, which had experienced CRUD-related fuel rod failures, had actual CRUD-scrape data to compare with results. As results show, the initial CTF/MAMBA1D-predicted CRUD thicknesses were about half of their expected values, so further investigation will be required for this simulation.« less
The Effect of Ocular Surface Regularity on Contrast Sensitivity and Straylight in Dry Eye.
Koh, Shizuka; Maeda, Naoyuki; Ikeda, Chikako; Asonuma, Sanae; Ogawa, Mai; Hiraoka, Takahiro; Oshika, Tetsuro; Nishida, Kohji
2017-05-01
To investigate the association between visual function and ocular surface regularity in dry eye. We enrolled 52 eyes of 52 dry eye patients (34 dry eyes with superficial punctate keratopathy [SPK] in the central corneal region [central SPK] and 18 dry eyes without central SPK) and 20 eyes of 20 normal control subjects. All eyes had a best-corrected distance visual acuity better than 20/20. We measured two indices of contrast sensitivity function under photopic conditions: contrast sensitivity and letter contrast sensitivity. The area under the log contrast sensitivity function (AULCSF) was calculated from the obtained contrast sensitivity data. Straylight was quantified using a straylight meter. Dry eyes with central SPK had significantly decreased contrast sensitivity function, including AULCSF and letter contrast sensitivity than those without central SPK and normal eyes (P < 0.05 for each). While the straylight values in both dry eye groups did not differ, straylight values were greater than those in normal eyes (P < 0.05 for both). In dry eye, the AULCSF and letter contrast sensitivity negatively correlated with the central SPK score (R = -0.485, P < 0.001, and R = -0.541, P < 0.001, respectively). In dry eye, reduced contrast sensitivity in part results from central SPK overlying the optical zone and the increased straylight results from tear film instability rather than central SPK.
Shamsi Meymandi, Manzumeh; Soltani, Zahra; Sepehri, Gholamreza; Amiresmaili, Sedigheh; Farahani, Fatemeh; Moeini Aghtaei, Mohammadmehdi
2018-05-03
Brain edema and increased intracranial pressure (ICP) are among the main causes of neurological disturbance and mortality following traumatic brain injury (TBI). Since pregabalin neuroprotective effects have been shown, this study was performed to evaluate the possible neuroprotective effects of pregabalin in experimental TBI of male rats. Adult male Wistar rats were divided into 4 groups: sham, vehicle, pregabalin 30 mg/kg and pregabalin 60 mg/kg. TBI was induced in vehicle and pregabalin groups by Marmarou method. Pregabalin was administered 30 min after TBI. Sham and vehicle groups received saline. Brain water and Evans blue content and histopathological changes were evaluated 24, 5 and 24 h after TBI, respectively. The ICP and neurological outcomes (veterinary coma scale, VCS) were recorded before, 1 h and 24 h post TBI. The results showed a significant reduction in brain water content and ICP, and a significant increase in VCS of pregabalin group (60 mg/kg) as compared to vehicle group (P < 0.05). Also, pregabalin reduced brain edema and apoptosis score as compared to vehicle group. Post TBI pregabalin administration revealed a delayed but significant improvement in ICP and neurological outcomes in experimental TBI. The underlying mechanism(s) was not determined and needs further investigation. Copyright © 2018 Elsevier Inc. All rights reserved.
Breakthrough Listen on MWA Pilot Study
NASA Astrophysics Data System (ADS)
Croft, S.; Siemion, A.; Kaplan, D. L.; Tremblay, S.
2016-07-01
We propose a pilot study, using the Voltage Capture System, for Breakthrough Listen on the MWA. Breakthrough Listen (BL) is a major new project that aims to dramatically improve the coverage of parameter space in the search for intelligent life beyond Earth. BL has already deployed hardware and software to the Green Bank Telescope, and will bring a similar program with the Parkes Telescope online in the second half of 2016. The low frequency sky is however currently very poorly explored. The superb capabilities of the MWA (large field of view, low frequency of operation, and location in a very radio quiet site) provide a unique opportunity for a pilot study to obtain voltage data for a SETI (Search For Extraterrestrial Intelligence) study of the Galactic Plane. We propose commensal observations, piggybacking on the proposed pulsar search of Tremblay et al. Using existing VCS software, combined with the pipeline developed for Breakthrough Listen at GBT and Parkes, we will perform a blind search for candidate signals from extraterrestrial intelligence. Although the chances of a detection are not large, particularly for a pilot study such as that proposed here, the Breakthrough Listen team plan to perform extensive testing and analysis on the data obtained which should be useful for other users of the MWA VCS. We will make the secondary SETI data products and associated documentation available as a resource to the community via the Breakthrough Listen online archive.
Tinkler, Justine E; Bunker Whittington, Kjersten; Ku, Manwai C; Davies, Andrea Rees
2015-05-01
Research on gender and workplace decision-making tends to address either supply-side disparities between men's and women's human and social capital, or demand-side differences in the status expectations of women and men workers. In addition, this work often relies on causal inferences drawn from empirical data collected on worker characteristics and their workplace outcomes. In this study, we demonstrate how tangible education and work history credentials - typically associated with supply-side characteristics - work in tandem with cultural beliefs about gender to influence the evaluative process that underlies venture capital decisions made in high-growth, high-tech entrepreneurship. Using an experimental design, we simulate funding decisions by venture capitalists (VCs) for men and women entrepreneurs that differ in technical background and the presence of important social ties. We demonstrate the presence of two distinct aspects of VCs' evaluation: that of the venture and that of the entrepreneur, and find that the gender of the entrepreneur influences evaluations most when the person, rather than the venture, is the target of evaluation. Technical background qualifications moderate the influence of gendered expectations, and women receive more of a payoff than men from having a close contact to the evaluating VC. We discuss the implications for future research on gender and work. Copyright © 2014 Elsevier Inc. All rights reserved.
Tracking interstellar space weather toward timing-array millisecond pulsars
NASA Astrophysics Data System (ADS)
Bhat, N. D. R.; Ord, S. M.; Tremblay, S. E.; Shannon, R. M.; van Straten, W.; Kaplan, D. L.; Macquart, J.-P.; Kirsten, F.
2016-07-01
Recent LIGO detection of milli-Hertz gravitational wave (GW) signals from a black-hole merger event has further reinforced the important role of Pulsar timing array (PTA) experiments in the GW astronomy. PTAs exploit the clock-like stability of fast-spinning millisecond pulsars (MSPs) to make a direct detection of ultra-low frequency (nano-Hertz) gravitational waves. The science enabled by PTAs is thus highly complementary to that possible by LIGO-like detectors. PTAs are also a key science objective for the SKA. PTA efforts over the past few years suggest that interstellar propagation effects on pulsar signals may ultimately limit the detection sensitivity of PTAs unless they are accurately measured and corrected for in timing measurements. Interstellar medium (ISM) effects are much stronger at lower radio frequencies and therefore the MWA presents an exciting and unique opportunity to calibrate interstellar propagation delays. This will potentially lead to enhanced sensitivity and scientific impact of PTA projects. Since our first demonstration of ability to form a coherent (tied-array) beam by reprocessing the recorded VCS data (Bhat et al. 2016), we have successfully ported the full processing chain to the Galaxy cluster of Pawsey and demonstrated the value of high-sensitivity multi-band pulsar observations that are now possible with the MWA. Here we propose further observations of two most promising PTA pulsars that will be nightly objects in the 2016B period. Our main science driver is to characterise the nature of the turbulent ISM through high-quality scintillation and dispersion studies including the investigation of chromatic (frequency-dependent) DMs. Success of these efforts will define the breadth and scope of a more ambitious program in the future, bringing in a new science niche for the MWA and SKA-low.
Optical defocus: differential effects on size and contrast letter recognition thresholds.
Rabin, J
1994-02-01
To determine if optical defocus produces a greater reduction in visual acuity or small-letter contrast sensitivity. Letter charts were used to measure visual acuity and small-letter contrast sensitivity (20/25 Snellen equivalent) as a function of optical defocus. Letter size (acuity) and contrast (contrast sensitivity) were varied in equal logarithmic steps to make the task the same for the two types of measurement. Both visual acuity and contrast sensitivity declined with optical defocus, but the effect was far greater in the contrast domain. However, measurement variability also was greater for contrast sensitivity. After correction for this variability, measurement in the contrast domain still proved to be a more sensitive (1.75x) index of optical defocus. Small-letter contrast sensitivity is a powerful technique for detecting subtle amounts of optical defocus. This adjunctive approach may be useful when there are small changes in resolution that are not detected by standard measures of visual acuity. Potential applications include evaluating the course of vision in refractive surgery, classification of cataracts, detection of corneal or macular edema, and detection of visual loss in the aging eye. Evaluation of candidates for occupations requiring unique visual abilities also may be enhanced by measuring resolution in the contrast domain.
2007-06-01
Joint At the exit of the expansion tank, a polymeric composition of ethylene-propylene- diene terpolymer ( EPDM ) rubber was used to mate the flange of...The final connection of the detonator was cumbersome for an operator wearing thick butyl rubber gloves. The detonator wire connection was made to a...operators were required to wear PPE, including rubber gloves. The decision was made to transfer the PLC components to outside the VCS. In Phase I, the
The Ohio Contrast Cards: Visual Performance in a Pediatric Low-vision Site
Hopkins, Gregory R.; Dougherty, Bradley E.; Brown, Angela M.
2017-01-01
SIGNIFICANCE This report describes the first clinical use of the Ohio Contrast Cards, a new test that measures the maximum spatial contrast sensitivity of low-vision patients who cannot recognize and identify optotypes and for whom the spatial frequency of maximum contrast sensitivity is unknown. PURPOSE To compare measurements of the Ohio Contrast Cards to measurements of three other vision tests and a vision-related quality-of-life questionnaire obtained on partially sighted students at Ohio State School for the Blind. METHODS The Ohio Contrast Cards show printed square-wave gratings at very low spatial frequency (0.15 cycle/degree). The patient looks to the left/right side of the card containing the grating. Twenty-five students (13 to 20 years old) provided four measures of visual performance: two grating card tests (the Ohio Contrast Cards and the Teller Acuity Cards) and two letter charts (the Pelli-Robson contrast chart and the Bailey-Lovie acuity chart). Spatial contrast sensitivity functions were modeled using constraints from the grating data. The Impact of Vision Impairment on Children questionnaire measured vision-related quality of life. RESULTS Ohio Contrast Card contrast sensitivity was always less than 0.19 log10 units below the maximum possible contrast sensitivity predicted by the model; average Pelli-Robson letter contrast sensitivity was near the model prediction, but 0.516 log10 units below the maximum. Letter acuity was 0.336 logMAR below the grating acuity results. The model estimated the best testing distance in meters for optimum Pelli-Robson contrast sensitivity from the Bailey-Lovie acuity as distance = 1.5 − logMAR for low-vision patients. Of the four vision tests, only Ohio Contrast Card contrast sensitivity was independently and statistically significantly correlated with students' quality of life. CONCLUSIONS The Ohio Contrast Cards combine a grating stimulus, a looking indicator behavior, and contrast sensitivity measurement. They show promise for the clinical objective of advising the patient and his/her caregivers about the success the patient is likely to enjoy in tasks of everyday life. PMID:28972542
Visual Contrast Sensitivity in Early-Stage Parkinson's Disease.
Ming, Wendy; Palidis, Dimitrios J; Spering, Miriam; McKeown, Martin J
2016-10-01
Visual impairments are frequent in Parkinson's disease (PD) and impact normal functioning in daily activities. Visual contrast sensitivity is a powerful nonmotor sign for discriminating PD patients from controls. However, it is usually assessed with static visual stimuli. Here we examined the interaction between perception and eye movements in static and dynamic contrast sensitivity tasks in a cohort of mildly impaired, early-stage PD patients. Patients (n = 13) and healthy age-matched controls (n = 12) viewed stimuli of various spatial frequencies (0-8 cyc/deg) and speeds (0°/s, 10°/s, 30°/s) on a computer monitor. Detection thresholds were determined by asking participants to adjust luminance contrast until they could just barely see the stimulus. Eye position was recorded with a video-based eye tracker. Patients' static contrast sensitivity was impaired in the intermediate spatial-frequency range and this impairment correlated with fixational instability. However, dynamic contrast sensitivity and patients' smooth pursuit were relatively normal. An independent component analysis revealed contrast sensitivity profiles differentiating patients and controls. Our study simultaneously assesses perceptual contrast sensitivity and eye movements in PD, revealing a possible link between fixational instability and perceptual deficits. Spatiotemporal contrast sensitivity profiles may represent an easily measurable metric as a component of a broader combined biometric for nonmotor features observed in PD.
Dees, Elise W; Gilson, Stuart J; Neitz, Maureen; Baraas, Rigmor C
2015-11-01
Chromatic contrast sensitivity may be a more sensitive measure of an individual's visual function than achromatic contrast sensitivity. Here, the first aim was to quantify individual- and age-related variations in chromatic contrast sensitivity to a range of spatial frequencies for stimuli along two complementary directions in color space. The second aim was to examine whether polymorphisms at specific amino acid residues of the L- and M-opsin genes (OPN1LW and OPN1MW) known to affect spectral tuning of the photoreceptors could influence spatio-chromatic contrast sensitivity. Chromatic contrast sensitivity functions were measured in 50 healthy individuals (20-71 years) employing a novel pseudo-isochromatic grating stimulus. The spatio-chromatic contrast sensitivity functions were found to be low pass for all subjects, independent of age and color vision. The results revealed a senescent decline in spatio-chromatic contrast sensitivity. There were considerable between-individual differences in sensitivity within each age decade for individuals 49 years old or younger, and age did not predict sensitivity for these age decades alone. Forty-six subjects (including a color deficient male and eight female carriers) were genotyped for L- and M-opsin genes. The Ser180Ala polymorphisms on the L-opsin gene were found to influence the subject's color discrimination and their sensitivity to spatio-chromatic patterns. The results expose the significant role of neural and genetic factors in the deterioration of visual function with increasing age. Copyright © 2015 Elsevier Ltd. All rights reserved.
Goetz, Georges; Smith, Richard; Lei, Xin; Galambos, Ludwig; Kamins, Theodore; Mathieson, Keith; Sher, Alexander; Palanker, Daniel
2015-01-01
Purpose To evaluate the contrast sensitivity of a degenerate retina stimulated by a photovoltaic subretinal prosthesis, and assess the impact of low contrast sensitivity on transmission of visual information. Methods We measure ex vivo the full-field contrast sensitivity of healthy rat retina stimulated with white light, and the contrast sensitivity of degenerate rat retina stimulated with a subretinal prosthesis at frequencies exceeding flicker fusion (>20 Hz). Effects of eye movements on retinal ganglion cell (RGC) activity are simulated using a linear–nonlinear model of the retina. Results Retinal ganglion cells adapt to high frequency stimulation of constant intensity, and respond transiently to changes in illumination of the implant, exhibiting responses to ON-sets, OFF-sets, and both ON- and OFF-sets of light. The percentage of cells with an OFF response decreases with progression of the degeneration, indicating that OFF responses are likely mediated by photoreceptors. Prosthetic vision exhibits reduced contrast sensitivity and dynamic range, with 65% contrast changes required to elicit responses, as compared to the 3% (OFF) to 7% (ON) changes with visible light. The maximum number of action potentials elicited with prosthetic stimulation is at most half of its natural counterpart for the ON pathway. Our model predicts that for most visual scenes, contrast sensitivity of prosthetic vision is insufficient for triggering RGC activity by fixational eye movements. Conclusions Contrast sensitivity of prosthetic vision is 10 times lower than normal, and dynamic range is two times below natural. Low contrast sensitivity and lack of OFF responses hamper delivery of visual information via a subretinal prosthesis. PMID:26540657
Perceptual Learning Improves Contrast Sensitivity of V1 Neurons in Cats
Hua, Tianmiao; Bao, Pinglei; Huang, Chang-Bing; Wang, Zhenhua; Xu, Jinwang
2010-01-01
Summary Background Perceptual learning has been documented in adult humans over a wide range of tasks. Although the often observed specificity of learning is generally interpreted as evidence for training-induced plasticity in early cortical areas, physiological evidence for training-induced changes in early visual cortical areas is modest, despite reports of learning-induced changes of cortical activities in fMRI studies. To reveal the physiological bases of perceptual learning, we combined psychophysical measurements with extracellular single-unit recording under anesthetized preparations, and examined the effects of training in grating orientation identification on both perceptual and neuronal contrast sensitivity functions of cats. Results We have found that training significantly improved perceptual contrast sensitivity of the cats to gratings with the spatial frequencies near the ‘trained’ spatial frequency, with stronger effects in the trained eye. Consistent with behavioral assessments, the mean contrast sensitivity of neurons recorded from V1 of the trained cats was significantly higher than that of neurons recorded from the untrained cats. Furthermore, in the trained cats, the contrast sensitivity of V1 neurons responding preferentially to stimuli presented via the trained eyes was significantly greater than that of neurons responding preferentially to stimuli presented via the ‘untrained’ eyes. The effect was confined to the trained spatial frequencies. In both trained and untrained cats, the neuronal contrast sensitivity functions derived from the contrast sensitivity of the individual neurons were highly correlated with behaviorally determined perceptual contrast sensitivity functions. Conclusions We suggest that training-induced neuronal contrast-gain in area V1 underlies behaviorally determined perceptual contrast sensitivity improvements. PMID:20451388
Ohno, Yoshiharu; Nishio, Mizuho; Koyama, Hisanobu; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Seki, Shinichiro; Sugimura, Kazuro
2014-03-01
The purpose of this article is to prospectively and directly compare the capabilities of non-contrast-enhanced MR angiography (MRA), 4D contrast-enhanced MRA, and contrast-enhanced MDCT for assessing pulmonary vasculature in patients with non-small cell lung cancer (NSCLC) before surgical treatment. A total of 77 consecutive patients (41 men and 36 women; mean age, 71 years) with pathologically proven and clinically assessed stage I NSCLC underwent thin-section contrast-enhanced MDCT, non-contrast-enhanced and contrast-enhanced MRA, and surgical treatment. The capability for anomaly assessment of the three methods was independently evaluated by two reviewers using a 5-point visual scoring system, and final assessment for each patient was made by consensus of the two readers. Interobserver agreement for pulmonary arterial and venous assessment was evaluated with the kappa statistic. Then, sensitivity, specificity, and accuracy for the detection of anomalies were directly compared among the three methods by use of the McNemar test. Interobserver agreement for pulmonary artery and vein assessment was substantial or almost perfect (κ=0.72-0.86). For pulmonary arterial and venous variation assessment, there were no significant differences in sensitivity, specificity, and accuracy among non-contrast-enhanced MRA (pulmonary arteries: sensitivity, 77.1%; specificity, 97.4%; accuracy, 87.7%; pulmonary veins: sensitivity, 50%; specificity, 98.5%; accuracy, 93.2%), 4D contrast-enhanced MRA (pulmonary arteries: sensitivity, 77.1%; specificity, 97.4%; accuracy, 87.7%; pulmonary veins: sensitivity, 62.5%; specificity, 100.0%; accuracy, 95.9%), and thin-section contrast-enhanced MDCT (pulmonary arteries: sensitivity, 91.4%; specificity, 89.5%; accuracy, 90.4%; pulmonary veins: sensitivity, 50%; specificity, 100.0%; accuracy, 95.9%) (p>0.05). Pulmonary vascular assessment of patients with NSCLC before surgical resection by non-contrast-enhanced MRA can be considered equivalent to that by 4D contrast-enhanced MRA and contrast-enhanced MDCT.
Trick, G L; Burde, R M; Gordon, M O; Santiago, J V; Kilo, C
1988-05-01
In an attempt to elucidate more fully the pathophysiologic basis of early visual dysfunction in patients with diabetes mellitus, color vision (hue discrimination) and spatial resolution (contrast sensitivity) were tested in diabetic patients with little or no retinopathy (n = 57) and age-matched visual normals (n = 35). Some evidence of visual dysfunction was observed in 37.8% of the diabetics with no retinopathy and 60.0% of the diabetics with background retinopathy. Although significant hue discrimination and contrast sensitivity deficits were observed in both groups of diabetic patients, contrast sensitivity was abnormal more frequently than hue discrimination. However, only 5.4% of the diabetics with no retinopathy and 10.0% of the diabetics with background retinopathy exhibited both abnormal hue discrimination and abnormal contrast sensitivity. Contrary to previous reports, blue-yellow (B-Y) and red-green (R-G) hue discrimination deficits were observed with approximately equal frequency. In the diabetic group, contrast sensitivity was reduced at all spatial frequencies tested, but for individual diabetic patients, significant deficits were only evident for the mid-range spatial frequencies. Among diabetic patients, the hue discrimination deficits, but not the contrast sensitivity abnormalities, were correlated with the patients' hemoglobin A1 level. A negative correlation between contrast sensitivity at 6.0 cpd and the duration of diabetes also was observed.
Torres-Ruiz, José M; Cochard, Hervé; Mayr, Stefan; Beikircher, Barbara; Diaz-Espejo, Antonio; Rodriguez-Dominguez, Celia M; Badel, Eric; Fernández, José Enrique
2014-11-01
Different methods have been devised to analyze vulnerability to cavitation of plants. Although a good agreement between them is usually found, some discrepancies have been reported when measuring samples from long-vesseled species. The aim of this study was to evaluate possible artifacts derived from different methods and sample sizes. Current-year shoot segments of mature olive trees (Olea europaea), a long-vesseled species, were used to generate vulnerability curves (VCs) by bench dehydration, pressure collar and both static- and flow-centrifuge methods. For the latter, two different rotors were used to test possible effects of the rotor design on the curves. Indeed, high-resolution computed tomography (HRCT) images were used to evaluate the functional status of xylem at different water potentials. Measurements of native embolism were used to validate the methods used. The pressure collar and the two centrifugal methods showed greater vulnerability to cavitation than the dehydration method. The shift in vulnerability thresholds in centrifuge methods was more pronounced in shorter samples, supporting the open-vessel artifact hypothesis as a higher proportion of vessels were open in short samples. The two different rotor designs used for the flow-centrifuge method revealed similar vulnerability to cavitation. Only the bench dehydration or HRCT methods produced VCs that agreed with native levels of embolism and water potential values measured in the field. © 2014 Scandinavian Plant Physiology Society.
NASA Astrophysics Data System (ADS)
Dallison, Stephen
A measurement has been made of the partial branching ratio, Rcs, of the W boson into a pair of jets originating from charmed (c) and strange (s) quarks. This was achieved by identifying final state hadrons among the decay products. Events generated using Monte Carlo simulations were used to construct multiplicity distributions for events where the W decays to cs quarks and events where the W decays to non-cs quarks. This was done by counting individually the numbers of K+/-, Ks0 and A candidates in each type of decay. These distributions were used as reference histograms and compared to multiplicity distributions for all hadronic events obtained using OPAL data taken from 1998 to 2000. The information derived from these distributions was used to extract a value of Values of Rcs were measured separately for charged kaons (K+/-), and neutral hadrons (Ks0 + Lambda). The charged kaon analysis was performed twice, once using an artificial neural network and again using a standard cut-based method. The values for the charged kaon and neutral hadron analyses were combined and weighted according to their overall errors. The final value for Rcs was found to be 0.499 +/- 0.060, Where the error represents a combination of the statistical and systematic uncertainties. The measured value of Rcs was used to determine a value for the CKM matrix element |Vcs|. This value was found to be |Vcs| = 0.999 +/- 0.060.
Production flush of Agaricus blazei on Brazilian casing layers
Colauto, Nelson Barros; da Silveira, Adriano Reis; da Eira, Augusto Ferreira; Linde, Giani Andrea
2011-01-01
This study aimed to verify the biological efficiency and production flushes of Agaricus blazei strains on different casing layers during 90 cultivation days. Four casing layers were used: mixture of subsoil and charcoal (VCS), lime schist (LSC), São Paulo peat (SPP) and Santa Catarina peat (SCP); and two genetically distant A. blazei strains. The fungus was grown in composted substratum and, after total colonization, a pasteurized casing layer was added over the substratum, and fructification was induced. Mushrooms were picked up daily when the basidiocarp veil was stretched, but before the lamella were exposed. The biological efficiency (BE) was determined by the fresh basidiocarp mass divided by the substratum dry mass, expressed in percentage. The production flushes were also determined over time production. The BE and production flushes during 90 days were affected by the strains as well as by the casing layers. The ABL26 and LSC produced the best BE of 60.4%. Although VCS is the most used casing layer in Brazil, it is inferior to other casing layers, for all strains, throughout cultivation time. The strain, not the casing layer, is responsible for eventual variations of the average mushroom mass. In average, circa 50% of the mushroom production occurs around the first month, 30% in the second month, and 20% in third month. The casing layer water management depends on the casing layer type and the strain. Production flush responds better to water reposition, mainly with ABL26, and better porosity to LSC and SCP casing layers. PMID:24031673
Chen, Long; Lin, Zhi-Xiong; Lin, Guo-Shi; Zhou, Chang-Fu; Chen, Yu-Peng; Wang, Xing-Fu; Zheng, Zong-Qing
2015-01-01
There are limited researches focusing on microvascular patterns (MVPs) in human glioblastoma and their prognostic impact. We evaluated MVPs of 78 glioblastomas by CD34/periodic acid-Schiff dual staining and by cluster analysis of the percentage of microvascular area for distinct microvascular formations. The distribution of 5 types of basic microvascular formations, that is, microvascular sprouting (MS), vascular cluster (VC), vascular garland (VG), glomeruloid vascular proliferation (GVP), and vasculogenic mimicry (VM), was variable. Accordingly, cluster analysis classified MVPs into 2 types: type I MVP displayed prominent MSs and VCs, whereas type II MVP had numerous VGs, GVPs, and VMs. By analyzing the proportion of microvascular area for each type of formation, we determined that glioblastomas with few MSs and VCs had many GVPs and VMs, and vice versa. VG seemed to be a transitional type of formation. In case of type I MVP, expression of Ki-67 and p53 but not MGMT was significantly higher as compared with those of type II MVP (P < .05). Survival analysis showed that the type of MVPs presented as an independent prognostic factor of progression-free survival (PFS) and overall survival (OS) (both P < .001). Type II MVP had a more negative influence on PFS and OS than did type I MVP. We conclude that the heterogeneous MVPs in glioblastoma can be categorized properly by certain histopathologic and statistical analyses and may influence clinical outcome. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.
Cross, Sheree E; Thompson, Melanie J; Roberts, Michael S
2003-02-01
As reductions in dermal clearance increase the residence time of solutes in the skin and underlying tissues we compared the topical penetration of potentially useful vasoconstrictors (VCs) through human epidermis as both free bases and ion-pairs with salicylic acid (SA). We determined the in vitro epidermal flux of ephedrine, naphazoline, oxymetazoline, phenylephrine, and xylometazoline applied as saturated solutions in propylene glycol:water (1:1) and of ephedrine, naphazoline and tetrahydrozoline as 10% solutions of 1:1 molar ratio ion-pairs with SA in liquid paraffin. As free bases, ephedrine had the highest maximal flux, Jmax = 77.4 +/- 11.7 microg/cm2/h, being 4-fold higher than tetrahydrozoline and xylometazoline, 6-fold higher than phenylephrine, 10-fold higher than naphazoline and 100-fold higher than oxymetazoline. Stepwise regression of solute physicochemical properties identified melting point as the most significant predictor of flux. As ion-pairs with SA, ephedrine and naphazoline had similar fluxes (11.5 +/- 2.3 and 12.0 +/- 1.6 microg/cm2/h respectively), whereas tetrahydrozoline was approximately 3-fold slower. Corresponding fluxes of SA from the ion-pairs were 18.6 +/- 0.6, 7.8+/- 0.8 and 1.1 +/- 0.1 respectively. Transdermal transport of VC's is discussed. Epidermal retention of VCs and SA did not correspond to their molar ratio on application and confirmed that following partitioning into the stratum corneum, ion-pairs separate and further penetration is governed by individual solute characteristics.
Barboni, Mirella Telles Salgueiro; Feitosa-Santana, Claudia; Barreto Junior, Jackson; Lago, Marcos; Bechara, Samir Jacob; Alves, Milton Ruiz; Ventura, Dora Fix
2013-10-01
The present study aimed to compare the postoperative contrast sensitivity functions between wavefront-guided LASIK eyes and their contralateral wavefront-guided PRK eyes. The participants were 11 healthy subjects (mean age=32.4 ± 6.2 years) who had myopic astigmatism. The spatial contrast sensitivity functions were measured before and three times after the surgery. Psycho and a Cambridge graphic board (VSG 2/4) were used to measure luminance, red-green, and blue-yellow spatial contrast sensitivity functions (from 0.85 to 13.1 cycles/degree). Longitudinal analysis and comparison between surgeries were performed. There was no significant contrast sensitivity change during the one-year follow-up measurements neither for LASIK nor for PRK eyes. The comparison between procedures showed no differences at 12 months postoperative. The present data showed similar contrast sensitivities during one-year follow-up of wave-front guided refractive surgeries. Moreover, one year postoperative data showed no differences in the effects of either wavefront-guided LASIK or wavefront-guided PRK on the luminance and chromatic spatial contrast sensitivity functions.
Clinical color vision testing and correlation with visual function.
Zhao, Jiawei; Davé, Sarita B; Wang, Jiangxia; Subramanian, Prem S
2015-09-01
To determine if Hardy-Rand-Rittler (H-R-R) and Ishihara testing are accurate estimates of color vision in subjects with acquired visual dysfunction. Assessment of diagnostic tools. Twenty-two subjects with optic neuropathy (aged 18-65) and 18 control subjects were recruited prospectively from an outpatient clinic. Individuals with visual acuity (VA) <20/200 or with congenital color blindness were excluded. All subjects underwent a comprehensive eye examination including VA, color vision, and contrast sensitivity testing. Color vision was assessed using H-R-R and Ishihara plates and Farnsworth D-15 (D-15) discs. D-15 is the accepted standard for detecting and classifying color vision deficits. Contrast sensitivity was measured using Pelli-Robson contrast sensitivity charts. No relationship was found between H-R-R and D-15 scores (P = .477). H-R-R score and contrast sensitivity were positively correlated (P = .003). On multivariate analysis, contrast sensitivity (β = 8.61, P < .001) and VA (β = 2.01, P = .022) both showed association with H-R-R scores. Similar to H-R-R, Ishihara score did not correlate with D-15 score (P = .973), but on multivariate analysis was related to contrast sensitivity (β = 8.69, P < .001). H-R-R and Ishihara scores had an equivalent relationship with contrast sensitivity (P = .069). Neither H-R-R nor Ishihara testing appears to assess color identification in patients with optic neuropathy. Both H-R-R and Ishihara testing are correlated with contrast sensitivity, and these tests may be useful clinical surrogates for contrast sensitivity testing. Copyright © 2015 Elsevier Inc. All rights reserved.
Spatial contrast sensitivity at twilight: luminance, monocularity, and oxygenation.
Connolly, Desmond M
2010-05-01
Visual performance in dim light is compromised by lack of oxygen (hypoxia). The possible influence of altered oxygenation on foveal contrast sensitivity under mesopic (twilight) viewing conditions is relevant to aircrew flying at night, including when using night vision devices, but is poorly documented. Foveal contrast sensitivity was measured binocularly and monocularly in 12 subjects at 7 spatial frequencies, ranging from 0.5 to approximately 16 cycles per degree, using sinusoidal Gabor patch gratings. Hypoxic performance breathing 14.1% oxygen, equivalent to altitude exposure at 3048 m (10,000 ft), was compared with breathing air at sea level (normoxia) at low photopic (28 cd x m(-2)), borderline upper mesopic (approximately 2.1 cd x m(-2)) and midmesopic (approximately 0.26 cd x m(-2)) luminance. Mesopic performance was also assessed breathing 100% oxygen (hyperoxia). Typical 'inverted U' log/log plots of the contrast sensitivity function were obtained, with elevated thresholds (reduced sensitivity) at lower luminance. Binocular viewing enhanced sensitivity by a factor approximating square root of 2 for most conditions, supporting neural summation of the contrast signal, but had greater influence at the lowest light level and highest spatial frequencies (8.26 and 16.51 cpd). Respiratory challenges had no effect. Contrast sensitivity is poorer when viewing monocularly and especially at midmesopic luminance, with relevance to night flying. The foveal contrast sensitivity function is unaffected by respiratory disturbance when twilight conditions favor cone vision, despite known effects on retinal illumination (pupil size). The resilience of the contrast sensitivity function belies the vulnerability of foveal low contrast acuity to mild hypoxia at mesopic luminance.
Kim, Yeon Jin; Reynaud, Alexandre; Hess, Robert F; Mullen, Kathy T
2017-07-01
The measurement of achromatic sensitivity has been an important tool for monitoring subtle changes in vision as the result of disease or response to therapy. In this study, we aimed to provide a normative data set for achromatic and chromatic contrast sensitivity functions within a common cone contrast space using an abbreviated measurement approach suitable for clinical practice. In addition, we aimed to provide comparisons of achromatic and chromatic binocular summation across spatial frequency. We estimated monocular cone contrast sensitivity functions (CCSFs) using a quick Contrast Sensitivity Function (qCSF) approach for achromatic as well as isoluminant, L/M cone opponent, and S cone opponent stimuli in a healthy population of 51 subjects. We determined the binocular CCSFs for achromatic and chromatic vision to evaluate the degree of binocular summation across spatial frequency for these three different mechanisms in a subset of 20 subjects. Each data set shows consistent contrast sensitivity across the population. They highlight the extremely high cone contrast sensitivity of L/M cone opponency compared with the S-cone and achromatic responses. We also find that the two chromatic sensitivities are correlated across the healthy population. In addition, binocular summation for all mechanisms depends strongly on stimulus spatial frequency. This study, using an approach well suited to the clinic, is the first to provide a comparative normative data set for the chromatic and achromatic contrast sensitivity functions, yielding quantitative comparisons of achromatic, L/M cone opponent, and S cone opponent chromatic sensitivities as a function of spatial frequency.
Peripheral resolution and contrast sensitivity: Effects of stimulus drift.
Venkataraman, Abinaya Priya; Lewis, Peter; Unsbo, Peter; Lundström, Linda
2017-04-01
Optimal temporal modulation of the stimulus can improve foveal contrast sensitivity. This study evaluates the characteristics of the peripheral spatiotemporal contrast sensitivity function in normal-sighted subjects. The purpose is to identify a temporal modulation that can potentially improve the remaining peripheral visual function in subjects with central visual field loss. High contrast resolution cut-off for grating stimuli with four temporal frequencies (0, 5, 10 and 15Hz drift) was first evaluated in the 10° nasal visual field. Resolution contrast sensitivity for all temporal frequencies was then measured at four spatial frequencies between 0.5 cycles per degree (cpd) and the measured stationary cut-off. All measurements were performed with eccentric optical correction. Similar to foveal vision, peripheral contrast sensitivity is highest for a combination of low spatial frequency and 5-10Hz drift. At higher spatial frequencies, there was a decrease in contrast sensitivity with 15Hz drift. Despite this decrease, the resolution cut-off did not vary largely between the different temporal frequencies tested. Additional measurements of contrast sensitivity at 0.5 cpd and resolution cut-off for stationary (0Hz) and 7.5Hz stimuli performed at 10, 15, 20 and 25° in the nasal visual field also showed the same characteristics across eccentricities. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Effect of anterior capsule contraction on visual function after cataract surgery.
Hayashi, Ken; Hayashi, Hideyuki
2007-11-01
To examine the effect of contraction of the anterior capsule opening after cataract surgery on visual acuity and contrast sensitivity. Hayashi Eye Hospital, Fukuoka, Japan. Thirty-two eyes of 32 consecutive patients who showed marked contraction of the anterior capsule opening after implantation of an intraocular lens were recruited. The area of the anterior capsule opening was measured by Scheimpflug videophotography before and after neodymium:YAG (Nd:YAG) laser anterior capsulotomy and was correlated with visual acuity and contrast sensitivity. After Nd:YAG laser anterior capsulotomy, the mean area of the anterior capsule opening increased significantly from 8.2 mm(2) to 18.0 mm(2) (P<.0001). Contrast sensitivity at most visual angles also improved significantly after Nd:YAG anterior capsulotomy, although visual acuity did not. The area of the anterior capsule opening before anterior capsulotomy was correlated significantly with contrast sensitivity but not with visual acuity, whereas there was no correlation between the opening area after anterior capsulotomy and visual acuity or contrast sensitivity. Contraction of the anterior capsule opening after cataract surgery significantly diminished contrast sensitivity in proportion to the opening area but did not markedly worsen visual acuity. Neodymium:YAG laser anterior capsulotomy improved contrast sensitivity.
The radio and optical counterpart of the new Fermi LAT flaring source J0109+6134
NASA Astrophysics Data System (ADS)
Paredes, J. M.; Martí, J.; Peracaula, M.
2010-02-01
Following the recent ATELs #2414, #2416 and #2420 concerning the Fermi-LAT, AGILE and Swift/XRT consistent detections of the new gamma-ray flaring source J0109+6134, we wish to remind that the proposed radio counterpart (VCS2 J0109+6133/GT 0106+613) was extensively observed nearly two decades ago by different authors in the context of the GT catalogue of Galactic Plane radio sources (Taylor and Gregory 1983, AJ, 88, 1784; Gregory and Taylor 1986, AJ 92, 371).
Converting virtual community members into online buyers.
Gupta, Sumeet; Kim, Hee-Woong; Shin, Seon-Jin
2010-10-01
Although many online vendors have sponsored virtual communities (VCs) in the hope of reaping commercial benefits from it, not many have been successful in reaping commercial benefits from their VC. Online vendors can benefit greatly from having a VC, if the VC members can be converted into online buyers. This study examines the conversion of a VC member into an online buyer. Using a classical-conditioning approach, this study finds that members' committed participation in the VC is the springboard for online vendors to convert VC members into online buyers.
75 FR 26851 - Privacy Act of 1974; System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-12
...As required by the Privacy Act of 1974, 5 U.S.C. 552a(e), notice is hereby given that the Department of Veterans Affairs (VA) is amending the system of records currently entitled ``Veterans Canteen Service (VCS) Payroll Deduction Program (PDP)-VA'' (117VA103) as set forth in the Federal Register 71 FR 6133. VA is amending the system of records by revising the Routine Uses of Records Maintained in the System, Including Categories of Users and the Purposes of Such Uses. VA is republishing the system notice in its entirety.
Exogenous attention enhances 2nd-order contrast sensitivity
Barbot, Antoine; Landy, Michael S.; Carrasco, Marisa
2011-01-01
Natural scenes contain a rich variety of contours that the visual system extracts to segregrate the retinal image into perceptually coherent regions. Covert spatial attention helps extract contours by enhancing contrast sensitivity for 1st-order, luminance-defined patterns at attended locations, while reducing sensitivity at unattended locations, relative to neutral attention allocation. However, humans are also sensitive to 2nd-order patterns such as spatial variations of texture, which are predominant in natural scenes and cannot be detected by linear mechanisms. We assess whether and how exogenous attention—the involuntary and transient capture of spatial attention—affects the contrast sensitivity of channels sensitive to 2nd-order, texture-defined patterns. Using 2nd-order, texture-defined stimuli, we demonstrate that exogenous attention increases 2nd-order contrast sensitivity at the attended location, while decreasing it at unattended locations, relative to a neutral condition. By manipulating both 1st- and 2nd-order spatial frequency, we find that the effects of attention depend both on 2nd-order spatial frequency of the stimulus and the observer’s 2nd-order spatial resolution at the target location. At parafoveal locations, attention enhances 2nd-order contrast sensitivity to high, but not to low 2nd-order spatial frequencies; at peripheral locations attention also enhances sensitivity to low 2nd-order spatial frequencies. Control experiments rule out the possibility that these effects might be due to an increase in contrast sensitivity at the 1st-order stage of visual processing. Thus, exogenous attention affects 2nd-order contrast sensitivity at both attended and unattended locations. PMID:21356228
Contrast Adaptation Implies Two Spatiotemporal Channels but Three Adapting Processes
ERIC Educational Resources Information Center
Langley, Keith; Bex, Peter J.
2007-01-01
The contrast gain control model of adaptation predicts that the effects of contrast adaptation correlate with contrast sensitivity. This article reports that the effects of high contrast spatiotemporal adaptors are maximum when adapting around 19 Hz, which is a factor of two or more greater than the peak in contrast sensitivity. To explain the…
Spatial Contrast Sensitivity in Adolescents with Autism Spectrum Disorders
ERIC Educational Resources Information Center
Koh, Hwan Cui; Milne, Elizabeth; Dobkins, Karen
2010-01-01
Adolescents with autism spectrum disorders (ASD) and typically developing (TD) controls underwent a rigorous psychophysical assessment that measured contrast sensitivity to seven spatial frequencies (0.5-20 cycles/degree). A contrast sensitivity function (CSF) was then fitted for each participant, from which four measures were obtained: visual…
Multi-step contrast sensitivity gauge
Quintana, Enrico C; Thompson, Kyle R; Moore, David G; Heister, Jack D; Poland, Richard W; Ellegood, John P; Hodges, George K; Prindville, James E
2014-10-14
An X-ray contrast sensitivity gauge is described herein. The contrast sensitivity gauge comprises a plurality of steps of varying thicknesses. Each step in the gauge includes a plurality of recesses of differing depths, wherein the depths are a function of the thickness of their respective step. An X-ray image of the gauge is analyzed to determine a contrast-to-noise ratio of a detector employed to generate the image.
The role of vision on hand preshaping during reach to grasp.
Winges, Sara A; Weber, Douglas J; Santello, Marco
2003-10-01
During reaching to grasp objects with different shapes hand posture is molded gradually to the object's contours. The present study examined the extent to which the temporal evolution of hand posture depends on continuous visual feedback. We asked subjects to reach and grasp objects with different shapes under five vision conditions (VCs). Subjects wore liquid crystal spectacles that occluded vision at four different latencies from onset of the reach. As a control, full-vision trials (VC5) were interspersed among the blocked vision trials. Object shapes and all VCs were presented to the subjects in random order. Hand posture was measured by 15 sensors embedded in a glove. Linear regression analysis, discriminant analysis, and information theory were used to assess the effect of removing vision on the temporal evolution of hand shape. We found that reach duration increased when vision was occluded early in the reach. This was caused primarily by a slower approach of the hand toward the object near the end of the reach. However, vision condition did not have a significant effect on the covariation patterns of joint rotations, indicating that the gradual evolution of hand posture occurs in a similar fashion regardless of vision. Discriminant analysis further supported this interpretation, as the extent to which hand posture resembled object shape and the rate at which hand posture discrimination occurred throughout the movement were similar across vision conditions. These results extend previous observations on memory-guided reaches by showing that continuous visual feedback of the hand and/or object is not necessary to allow the hand to gradually conform to object contours.
Spatial contrast sensitivity vision loss in children with cortical visual impairment.
Good, William V; Hou, Chuan; Norcia, Anthony M
2012-11-19
Although cortical visual impairment (CVI) is the leading cause of bilateral vision impairment in children in Western countries, little is known about the effects of CVI on visual function. The aim of this study was to compare visual evoked potential measures of contrast sensitivity and grating acuity in children with CVI with those of age-matched typically developing controls. The swept parameter visual evoked potential (sVEP) was used to measure contrast sensitivity and grating acuity in 34 children with CVI at 5 months to 5 years of age and in 16 age-matched control children. Contrast thresholds and spatial frequency thresholds (grating acuities) were derived by extrapolating the tuning functions to zero amplitude. These thresholds and maximal suprathreshold response amplitudes were compared between groups. Among 34 children with CVI, 30 had measurable but reduced contrast sensitivity with a median threshold of 10.8% (range 5.0%-30.0% Michelson), and 32 had measurable but reduced grating acuity with median threshold 0.49 logMAR (9.8 c/deg, range 5-14 c/deg). These thresholds were significantly reduced, compared with age-matched control children. In addition, response amplitudes over the entire sweep range for both measures were significantly diminished in children with CVI compared with those of control children. Our results indicate that spatial contrast sensitivity and response amplitudes are strongly affected by CVI. The substantial degree of loss in contrast sensitivity suggests that contrast is a sensitive measure for evaluating vision deficits in patients with CVI.
Barbot, Antoine; Landy, Michael S.; Carrasco, Marisa
2012-01-01
The visual system can use a rich variety of contours to segment visual scenes into distinct perceptually coherent regions. However, successfully segmenting an image is a computationally expensive process. Previously we have shown that exogenous attention—the more automatic, stimulus-driven component of spatial attention—helps extract contours by enhancing contrast sensitivity for second-order, texture-defined patterns at the attended location, while reducing sensitivity at unattended locations, relative to a neutral condition. Interestingly, the effects of exogenous attention depended on the second-order spatial frequency of the stimulus. At parafoveal locations, attention enhanced second-order contrast sensitivity to relatively high, but not to low second-order spatial frequencies. In the present study we investigated whether endogenous attention—the more voluntary, conceptually-driven component of spatial attention—affects second-order contrast sensitivity, and if so, whether its effects are similar to those of exogenous attention. To that end, we compared the effects of exogenous and endogenous attention on the sensitivity to second-order, orientation-defined, texture patterns of either high or low second-order spatial frequencies. The results show that, like exogenous attention, endogenous attention enhances second-order contrast sensitivity at the attended location and reduces it at unattended locations. However, whereas the effects of exogenous attention are a function of the second-order spatial frequency content, endogenous attention affected second-order contrast sensitivity independent of the second-order spatial frequency content. This finding supports the notion that both exogenous and endogenous attention can affect second-order contrast sensitivity, but that endogenous attention is more flexible, benefitting performance under different conditions. PMID:22895879
Spiegel, Daniel P; Reynaud, Alexandre; Ruiz, Tatiana; Laguë-Beauvais, Maude; Hess, Robert; Farivar, Reza
2016-05-01
Vision is disrupted by traumatic brain injury (TBI), with vision-related complaints being amongst the most common in this population. Based on the neural responses of early visual cortical areas, injury to the visual cortex would be predicted to affect both 1(st) order and 2(nd) order contrast sensitivity functions (CSFs)-the height and/or the cut-off of the CSF are expected to be affected by TBI. Previous studies have reported disruptions only in 2(nd) order contrast sensitivity, but using a narrow range of parameters and divergent methodologies-no study has characterized the effect of TBI on the full CSF for both 1(st) and 2(nd) order stimuli. Such information is needed to properly understand the effect of TBI on contrast perception, which underlies all visual processing. Using a unified framework based on the quick contrast sensitivity function, we measured full CSFs for static and dynamic 1(st) and 2(nd) order stimuli. Our results provide a unique dataset showing alterations in sensitivity for both 1(st) and 2(nd) order visual stimuli. In particular, we show that TBI patients have increased sensitivity for 1(st) order motion stimuli and decreased sensitivity to orientation-defined and contrast-defined 2(nd) order stimuli. In addition, our data suggest that TBI patients' sensitivity for both 1(st) order stimuli and 2(nd) order contrast-defined stimuli is shifted towards higher spatial frequencies. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Sun, Hao; Swanson, William H.; Arvidson, Brian; Dul, Mitchell W.
2010-01-01
PURPOSE Contrast gain signatures of inferred magnocellular and parvocellular postreceptoral pathways were assessed for patients with glaucoma using a contrast discrimination paradigm developed by Pokorny and Smith. The potential causes for changes in contrast gain signature were investigated using model simulations of ganglion cell contrast responses. METHODS Foveal contrast discrimination thresholds were measured with a pedestal-Δ-pedestal paradigm developed by Pokorny and Smith (1997). Stimuli were 27 msec luminance increments superimposed on 227 msec pulsed Δ-pedestals. Contrast thresholds and contrast gain signatures mediated by the inferred magnocellular (MC) and parvocellular (PC) pathways were assessed using linear fits to contrast discrimination thresholds at either lower or higher Δ-pedestal contrasts, respectively. Twenty-seven patients with glaucoma were tested, as well as 16 age-similar control subjects free of eye disease. RESULTS Contrast sensitivity and contrast gain signature mediated by the inferred MC pathway were lower for the glaucoma group, and reduced contrast gain signature was correlated with reduced contrast sensitivity (r2=45%, p<0.0005). These two parameters mediated by the inferred PC pathway were little affected for the glaucoma group. Model simulations suggest that the reduced contrast sensitivity and contrast gain signature were consistent with the hypothesis that reduced MC ganglion cell dendritic complexity can lead to reduced effective retinal illuminance, and hence increased semi-saturation contrast of the ganglion cell contrast response functions. CONCLUSIONS The contrast sensitivity and contrast gain signature of the inferred MC pathway were reduced in patients with glaucoma. The results were consistent with a model of ganglion cell dysfunction due to reduced synaptic density. PMID:18501947
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schultz, A.W.; Leavitt, W.Z.
A preliminary study was conducted to determine the feasiblllty of uslng neutron radiography for examining ordnance materials. Depleted U and 4140 steel castings in various thicknesses were examined. In addition, a thin section of Be, a grasshopper and a cricket were radiographed to illustrate the ability of neutrons to determine defects in low-density materials. For uranium thicknesses up to 5 in., a contrast sensitivity between 1.5 and 7.5%o was obtained using thermal neutrons, In foil, and industrial x-ray film transfer techniques. For 6 in. of U, a contrast sensitivity between 6.3 and 12.5% was obtained. For U thicknesses up tomore » 6 in., a detail sensitivity of 2.1% was obtained. For thicknesses up to 4 in. of steel, a contrast sensitivity between 1.9 and 9.4% and a detail sensitivity between 0.8 and 3.1% were obtained. For 5.125 and 6 in. of steel, contrast sensitivities between 14.6 and 29.2% and 14.6 and 39.6%, respectively, and detail sensitivities of no less than 4.9% were obtained. Both a contrast and a detail sensitivity of about 5% were obtained in examining a thin section of Be. Recommendations for further studies are given. (auth)« less
Liu, Rong; Zhou, Jiawei; Zhao, Haoxin; Dai, Yun; Zhang, Yudong; Tang, Yong; Zhou, Yifeng
2014-01-01
This study aimed to explore the neural development status of the visual system of children (around 8 years old) using contrast sensitivity. We achieved this by eliminating the influence of higher order aberrations (HOAs) with adaptive optics correction. We measured HOAs, modulation transfer functions (MTFs) and contrast sensitivity functions (CSFs) of six children and five adults with both corrected and uncorrected HOAs. We found that when HOAs were corrected, children and adults both showed improvements in MTF and CSF. However, the CSF of children was still lower than the adult level, indicating the difference in contrast sensitivity between groups cannot be explained by differences in optical factors. Further study showed that the difference between the groups also could not be explained by differences in non-visual factors. With these results we concluded that the neural systems underlying vision in children of around 8 years old are still immature in contrast sensitivity. PMID:24732728
Adaptive voting computer system
NASA Technical Reports Server (NTRS)
Koczela, L. J.; Wilgus, D. S. (Inventor)
1974-01-01
A computer system is reported that uses adaptive voting to tolerate failures and operates in a fail-operational, fail-safe manner. Each of four computers is individually connected to one of four external input/output (I/O) busses which interface with external subsystems. Each computer is connected to receive input data and commands from the other three computers and to furnish output data commands to the other three computers. An adaptive control apparatus including a voter-comparator-switch (VCS) is provided for each computer to receive signals from each of the computers and permits adaptive voting among the computers to permit the fail-operational, fail-safe operation.
Hood, A S; Morrison, J D
2002-01-01
We have measured monocular and binocular contrast sensitivities in response to medium to high spatial frequencies of vertical sinusoidal grating patterns in normal subjects, anisometropic amblyopes, strabismic amblyopes and non-amblyopic esotropes. On binocular viewing, contrast sensitivities were slightly but significantly increased in normal subjects, markedly increased in anisometropes and esotropes with anomalous binocular single vision (BSV) and significantly reduced in esotropes and exotropes without BSV. Application of a prismatic correction to the strabismic eye in order to achieve bifoveal stimulation resulted in a significant reduction in contrast sensitivity in esotropes with and without anomalous BSV, in exotropes and in non-amblyopic esotropes. Control experiments in normal subjects with monocular viewing showed that degradative effects of the prism occurred only with high prism powers and at high spatial frequencies, thus establishing that the reduced contrast sensitivities were the consequence of bifoveal stimulation rather than optical degradation. Displacement of the image of the grating pattern by 2 deg in normal subjects and anisometropes by a dichoptic method to simulate a small angle esotropia had no effect on the contrast sensitivities recorded through the companion eye. By contrast, esotropes showed similar reductions in contrast sensitivity to those obtained with the prism experiments, confirming a fundamental difference between subjects with normal and abnormal ocular alignments. The results have thus established a suppressive action of the fovea of the amblyopic eye acting on the companion, non-amblyopic eye and indicate that correction of ocular misalignments in adult esotropes may be disadvantageous to binocular visual performance. PMID:11956347
Genetic influence on contrast sensitivity in middle-aged male twins.
Cronin-Golomb, Alice; Panizzon, Matthew S; Lyons, Michael J; Franz, Carol E; Grant, Michael D; Jacobson, Kristen C; Eisen, Seth A; Laudate, Thomas M; Kremen, William S
2007-07-01
Contrast sensitivity is strongly associated with daily functioning among older adults, but the genetic and environmental contributions to this ability are unknown. Using the classical twin method, we addressed this issue by examining contrast sensitivity at five spatial frequencies (1.5-18 cycles per degree) in 718 middle-aged male twins from the Vietnam Era Twin Study of Aging (VETSA). Heritability estimates were modest (14-38%), whereas individual-specific environmental influences accounted for 62-86% of the variance. Identifying the types of individual-specific events that impact contrast sensitivity may suggest interventions to modulate this ability and thereby improve overall quality of life as adults age.
Effect of aberrations in human eye on contrast sensitivity function
NASA Astrophysics Data System (ADS)
Quan, Wei; Wang, Feng-lin; Wang, Zhao-qi
2011-06-01
The quantitative analysis of the effect of aberrations in human eye on vision has important clinical value in the correction of aberrations. The wave-front aberrations of human eyes were measured with the Hartmann-Shack wave-front sensor and modulation transfer function (MTF) was computed from the wave-front aberrations. Contrast sensitivity function (CSF) was obtained from MTF and the retinal aerial image modulation (AIM). It is shown that the 2nd, 3rd, 4th, 5th, 6th Zernike aberrations deteriorate contrast sensitivity function. When the 2nd, 3rd, 4th, 5th, 6th Zernike aberrations are corrected high contrast sensitivity function can be obtained.
Sun, Hao; Swanson, William H; Arvidson, Brian; Dul, Mitchell W
2008-11-01
Contrast gain signatures of inferred magnocellular and parvocellular postreceptoral pathways were assessed for patients with glaucoma using a contrast discrimination paradigm developed by Pokorny and Smith. The potential causes for changes in contrast gain signature were investigated using model simulations of ganglion cell contrast responses. Foveal contrast discrimination thresholds were measured with a pedestal-Delta-pedestal paradigm developed by Pokorny and Smith [Pokorny, J., & Smith, V. C. (1997). Psychophysical signatures associated with magnocellular and parvocellular pathway contrast gain. Journal of the Optical Society of America A, 14(9), 2477-2486]. Stimuli were 27 ms luminance increments superimposed on 227 ms pulsed Delta-pedestals. Contrast thresholds and contrast gain signatures mediated by the inferred magnocellular (MC) and parvocellular (PC) pathways were assessed using linear fits to contrast discrimination thresholds at either lower or higher Delta-pedestal contrasts, respectively. Twenty-seven patients with glaucoma were tested, as well as 16 age-similar control subjects free of eye disease. Contrast sensitivity and contrast gain signature mediated by the inferred MC pathway were lower for the glaucoma group, and reduced contrast gain signature was correlated with reduced contrast sensitivity (r(2)=45%, p<.0005). These two parameters mediated by the inferred PC pathway were little affected for the glaucoma group. Model simulations suggest that the reduced contrast sensitivity and contrast gain signature were consistent with the hypothesis that reduced MC ganglion cell dendritic complexity can lead to reduced effective retinal illuminance, and hence increased semi-saturation contrast of the ganglion cell contrast response functions. The contrast sensitivity and contrast gain signature of the inferred MC pathway were reduced in patients with glaucoma. The results were consistent with a model of ganglion cell dysfunction due to reduced synaptic density.
Barboni, M.T.S.; Gomes, B.D.; Souza, G.S.; Rodrigues, A.R.; Ventura, D.F.; Silveira, L.C.L.
2013-01-01
The purpose of the present study was to measure contrast sensitivity to equiluminant gratings using steady-state visual evoked cortical potential (ssVECP) and psychophysics. Six healthy volunteers were evaluated with ssVECPs and psychophysics. The visual stimuli were red-green or blue-yellow horizontal sinusoidal gratings, 5° × 5°, 34.3 cd/m2 mean luminance, presented at 6 Hz. Eight spatial frequencies from 0.2 to 8 cpd were used, each presented at 8 contrast levels. Contrast threshold was obtained by extrapolating second harmonic amplitude values to zero. Psychophysical contrast thresholds were measured using stimuli at 6 Hz and static presentation. Contrast sensitivity was calculated as the inverse function of the pooled cone contrast threshold. ssVECP and both psychophysical contrast sensitivity functions (CSFs) were low-pass functions for red-green gratings. For electrophysiology, the highest contrast sensitivity values were found at 0.4 cpd (1.95 ± 0.15). ssVECP CSF was similar to dynamic psychophysical CSF, while static CSF had higher values ranging from 0.4 to 6 cpd (P < 0.05, ANOVA). Blue-yellow chromatic functions showed no specific tuning shape; however, at high spatial frequencies the evoked potentials showed higher contrast sensitivity than the psychophysical methods (P < 0.05, ANOVA). Evoked potentials can be used reliably to evaluate chromatic red-green CSFs in agreement with psychophysical thresholds, mainly if the same temporal properties are applied to the stimulus. For blue-yellow CSF, correlation between electrophysiology and psychophysics was poor at high spatial frequency, possibly due to a greater effect of chromatic aberration on this kind of stimulus. PMID:23369980
Impaired temporal contrast sensitivity in dyslexics is specific to retain-and-compare paradigms.
Ben-Yehudah, G; Sackett, E; Malchi-Ginzberg, L; Ahissar, M
2001-07-01
Developmental dyslexia is a specific reading disability that affects 5-10% of the population. Recent studies have suggested that dyslexics may experience a deficit in the visual magnocellular pathway. The most extensively studied prediction deriving from this hypothesis is impaired contrast sensitivity to transient, low-luminance stimuli at low spatial frequencies. However, the findings are inconsistent across studies and even seemingly contradictory. In the present study, we administered several different paradigms for assessing temporal contrast sensitivity, and found both impaired and normal contrast sensitivity within the same group of dyslexic participants. Under sequential presentation, in a temporal forced choice paradigm, dyslexics showed impaired sensitivity to both drifting and flickering gratings. However, under simultaneous presentation, with a spatial forced choice paradigm, dyslexics' sensitivity did not differ from that of the controls. Within each paradigm, dyslexics' sensitivity was poorer at higher temporal frequencies, consistent with the magnocellular hypothesis. These results suggest that a basic perceptual impairment in dyslexics may be their limited ability to retain-and-compare perceptual traces across brief intervals.
Genetic Influence on Contrast Sensitivity in Middle-Aged Male Twins
Cronin-Golomb, Alice; Panizzon, Matthew S.; Lyons, Michael J.; Franz, Carol E.; Grant, Michael D.; Jacobson, Kristen C.; Eisen, Seth A.; Laudate, Thomas M.; Kremen, William S.
2007-01-01
Contrast sensitivity is strongly associated with daily functioning among older adults, but the genetic and environmental contributions to this ability are unknown. Using the classical twin method, we addressed this issue by examining contrast sensitivity at five spatial frequencies (1.5–18 cycles per degree) in 718 middle-aged male twins from the Vietnam Era Twin Study of Aging (VETSA). Heritability estimates were modest (14%–38%), whereas individual-specific environmental influences accounted for 62%–86% of the variance. Identifying the types of individual-specific events that impact contrast sensitivity may suggest interventions to modulate this ability and thereby improve overall quality of life as adults age. PMID:17604073
Toyooka, Kiminori; Sato, Mayuko; Kutsuna, Natsumaro; Higaki, Takumi; Sawaki, Fumie; Wakazaki, Mayumi; Goto, Yumi; Hasezawa, Seiichiro; Nagata, Noriko; Matsuoka, Ken
2014-09-01
Rapid growth of plant cells by cell division and expansion requires an endomembrane trafficking system. The endomembrane compartments, such as the Golgi stacks, endosome and vesicles, are important in the synthesis and trafficking of cell wall materials during cell elongation. However, changes in the morphology, distribution and number of these compartments during the different stages of cell proliferation and differentiation have not yet been clarified. In this study, we examined these changes at the ultrastructural level in tobacco Bright yellow 2 (BY-2) cells during the log and stationary phases of growth. We analyzed images of the BY-2 cells prepared by the high-pressure freezing/freeze substitution technique with the aid of an auto-acquisition transmission electron microscope system. We quantified the distribution of secretory and endosomal compartments in longitudinal sections of whole cells by using wide-range gigapixel-class images obtained by merging thousands of transmission electron micrographs. During the log phase, all Golgi stacks were composed of several thick cisternae. Approximately 20 vesicle clusters (VCs), including the trans-Golgi network and secretory vesicle cluster, were observed throughout the cell. In the stationary-phase cells, Golgi stacks were thin with small cisternae, and only a few VCs were observed. Nearly the same number of multivesicular body and small high-density vesicles were observed in both the stationary and log phases. Results from electron microscopy and live fluorescence imaging indicate that the morphology and distribution of secretory-related compartments dramatically change when cells transition from log to stationary phases of growth. © The Author 2014. Published by Oxford University Press on behalf of Japanese Society of Plant Physiologists. All rights reserved. For permissions, please email: journals.permissions@oup.com.
Savi, Tadeja; Miotto, Andrea; Petruzzellis, Francesco; Losso, Adriano; Pacilè, Serena; Tromba, Giuliana; Mayr, Stefan; Nardini, Andrea
2017-11-01
Vulnerability curves (VCs) are a useful tool to investigate the susceptibility of plants to drought-induced hydraulic failure, and several experimental techniques have been used for their measurement. The validity of the bench dehydration method coupled to hydraulic measurements, considered as a 'golden standard', has been recently questioned calling for its validation with non-destructive methods. We compared the VCs of a herbaceous crop plant (Helianthus annuus) obtained during whole-plant dehydration followed by i) hydraulic flow measurements in stem segments (classical destructive method) or by ii) in vivo micro-CT observations of stem xylem conduits in intact plants. The interpolated P 50 values (xylem water potential inducing 50% loss of hydraulic conductance) were -1.74 MPa and -0.87 MPa for the hydraulic and the micro-CT VC, respectively. Interpolated P 20 values were similar, while P 50 and P 80 were significantly different, as evidenced by non-overlapping 95% confidence intervals. Our results did not support the tension-cutting artefact, as no overestimation of vulnerability was observed when comparing the hydraulic VC to that obtained with in vivo imaging. After one scan, 25% of plants showed signs of x-ray induced damage, while three successive scans caused the formation of a circular brownish scar in all tested plants. Our results support the validity of hydraulic measurements of samples excised under tension provided standard sampling and handling protocols are followed, but also show that caution is needed when investigating vital plant processes with x-ray imaging. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Uniform apparent contrast noise: A picture of the noise of the visual contrast detection system
NASA Technical Reports Server (NTRS)
Ahumada, A. J., Jr.; Watson, A. B.
1984-01-01
A picture which is a sample of random contrast noise is generated. The noise amplitude spectrum in each region of the picture is inversely proportional to spatial frequency contrast sensitivity for that region, assuming the observer fixates the center of the picture and is the appropriate distance from it. In this case, the picture appears to have approximately the same contrast everywhere. To the extent that contrast detection thresholds are determined by visual system noise, this picture can be regarded as a picture of the noise of that system. There is evidence that, at different eccentricities, contrast sensitivity functions differ only by a magnification factor. The picture was generated by filtering a sample of white noise with a filter whose frequency response is inversely proportional to foveal contrast sensitivity. It was then stretched by a space-varying magnification function. The picture summmarizes a noise linear model of detection and discrimination of contrast signals by referring the model noise to the input picture domain.
Perceptual learning improves contrast sensitivity, visual acuity, and foveal crowding in amblyopia.
Barollo, Michele; Contemori, Giulio; Battaglini, Luca; Pavan, Andrea; Casco, Clara
2017-01-01
Amblyopic observers present abnormal spatial interactions between a low-contrast sinusoidal target and high-contrast collinear flankers. It has been demonstrated that perceptual learning (PL) can modulate these low-level lateral interactions, resulting in improved visual acuity and contrast sensitivity. We measured the extent and duration of generalization effects to various spatial tasks (i.e., visual acuity, Vernier acuity, and foveal crowding) through PL on the target's contrast detection. Amblyopic observers were trained on a contrast-detection task for a central target (i.e., a Gabor patch) flanked above and below by two high-contrast Gabor patches. The pre- and post-learning tasks included lateral interactions at different target-to-flankers separations (i.e., 2, 3, 4, 8λ) and included a range of spatial frequencies and stimulus durations as well as visual acuity, Vernier acuity, contrast-sensitivity function, and foveal crowding. The results showed that perceptual training reduced the target's contrast-detection thresholds more for the longest target-to-flanker separation (i.e., 8λ). We also found generalization of PL to different stimuli and tasks: contrast sensitivity for both trained and untrained spatial frequencies, visual acuity for Sloan letters, and foveal crowding, and partially for Vernier acuity. Follow-ups after 5-7 months showed not only complete maintenance of PL effects on visual acuity and contrast sensitivity function but also further improvement in these tasks. These results suggest that PL improves facilitatory lateral interactions in amblyopic observers, which usually extend over larger separations than in typical foveal vision. The improvement in these basic visual spatial operations leads to a more efficient capability of performing spatial tasks involving high levels of visual processing, possibly due to the refinement of bottom-up and top-down networks of visual areas.
Thakur, Sahil; Ichhpujani, Parul; Kumar, Suresh; Kaur, Ravneet; Sood, Sunandan
2018-05-14
This study was designed to assess the efficacy, reliability and repeatability of SPARCS (Spaeth Richman Contrast Sensitivity Test) as compared to the conventional Pelli Robson Chart Test for the assessment of contrast sensitivity in patients with glaucoma. We evaluated 135 eyes of 135 patients who were age and sex matched into three groups (controls, disc suspects and glaucoma) of 45 patients each. The glaucoma subgroup was further divided into subgroups of mild, moderate and severe based on the visual field damage. There was a strong positive correlation between Pelli Robson scores and SPARCS scores (S = 0.807, P < 0.001). Intraclass correlation coefficient (ICC) for Pelli Robson Test was 0.952 and 0.988 for SPARCS. The coefficient of repeatability (COR) for mean SPARCS was 5.65%, while COR of Pelli Robson Test was 12.44%. SPARCS was found to have better repeatability than Pelli Robson Test based on COR values. Pelli Robson score had a sensitivity of 80% and a specificity of 65.6% for detecting glaucoma patients as compared to 84.4% and 70%, respectively, for SPARCS scores. SPARCS is a better alternative to conventional Pelli Robson Chart Test for assessment of contrast sensitivity in patients with glaucoma. Being independent of the effects of literacy and educational status, it offers a universal way to measure contrast sensitivity. It can also be reliably used in patients with varying severity of glaucoma.
Shima, Toshihide; Mizuno, Masayuki; Otsuji, Hideaki; Mizuno, Chiemi; Obata, Hirozumi; Park, Hyohun; Nakajo, Shinobu; Okanoue, Takeshi
2005-09-01
The aim of this study was to assess and compare the sensitivity of power Doppler sonography, contrast-enhanced sonography, plain computed tomography (CT), and dynamic magnetic resonance imaging (MRI) for detecting hepatocellular carcinoma (HCC) nodules incompletely treated with transcatheter arterial embolization (TAE). A total of 63 unresectable HCC nodules were examined in this study. The HCCs were treated with TAE. All patients underwent plain CT, power Doppler sonography, contrast-enhanced harmonic power Doppler sonography, and dynamic MRI 1 week after TAE. The sensitivity of each modality to incompletely treated HCC nodules was compared. Detection of the residual viable HCC on angiography or tumor biopsy was regarded as the gold standard for the diagnosis of incomplete treatment. Twenty-four nodules (38%) were diagnosed as incompletely treated. The sensitivities of plain CT, power Doppler sonography, contrast-enhanced harmonic power Doppler sonography, and dynamic MRI to these incompletely treated nodules were 42% (10/24), 46% (11/24), 88% (21/24), and 79% (19/24), respectively. Eighty percent (19 nodules) of the 24 incompletely treated nodules were located within a depth of less than 8 cm. The sensitivities of plain CT, power Doppler sonography, contrast-enhanced harmonic power Doppler sonography, and dynamic MRI to these superficial incompletely treated nodules were 37% (7/19), 53% (10/19), 100% (19/19), and 74% (14/19), respectively. In contrast, the sensitivities of each modality to deeply located nodules were 60% (3/5), 20% (1/5), 40% (2/5), and 100% (5/5), respectively. Plain CT and power Doppler sonography had a low sensitivity to HCC nodules incompletely treated with TAE. Except for those that were deeply located, contrast-enhanced harmonic sonography showed the highest sensitivity in detecting incompletely treated HCC nodules.
Keane, Pearse A.; Patel, Praveen J.; Ouyang, Yanling; Chen, Fred K.; Ikeji, Felicia; Walsh, Alexander C.; Tufail, Adnan
2010-01-01
Purpose. To investigate the effect of changes in retinal morphology on contrast sensitivity and reading ability in patients with neovascular age-related macular degeneration (AMD) in the Avastin (bevacizumab; Genentech, South San Francisco, CA) for choroidal neovascularization (ABC) Trial. Methods. Contrast sensitivity obtained with Pelli-Robson charts, reading ability assessed with Minnesota Reading charts, and Early Treatment Diabetic Retinopathy Study (ETDRS) visual acuity (VA) obtained by protocol refraction, were recorded. Raw Stratus optical coherence tomography (OCT; Carl Zeiss Meditec, Inc., Dublin, CA) images were analyzed with the publicly available software OCTOR, which allows precise delineation of any retinal compartment of interest. Thickness and volume were calculated for neurosensory retina, subretinal fluid (SRF), subretinal tissue, and pigment epithelium detachment, and the resulting measurements were correlated with each visual function parameter. Results. One hundred twenty-two patients with newly diagnosed neovascular AMD and enrolled in the ABC Trial, were evaluated. Increased subretinal tissue volume correlated with decreased contrast sensitivity (Pearson's correlation coefficient, r = −0.4944, P = 0.001). A modest correlation was detected between SRF volume and contrast sensitivity (r = −0.2562, P = 0.004). Increased retinal thickness at the foveal center also correlated with decreased visual function (ETDRS VA: r = −0.4530, P < 0.001). Conclusions. The strongest correlation detected between the functional parameters assessed and any of the OCT-derived morphologic parameters was that between decreased contrast sensitivity and increased subretinal tissue. In the future, assessment of contrast sensitivity and reading ability, in combination with quantitative subanalysis of retinal compartments, may lead to the identification of parameters relevant to functional improvement and ultimate prognosis in patients with newly diagnosed neovascular AMD (www.controlled-trials.com number, ISRCTN83325075). PMID:20554607
NASA Astrophysics Data System (ADS)
Park, Subok; Badano, Aldo; Gallas, Brandon D.; Myers, Kyle J.
2007-03-01
Previously, a non-prewhitening matched filter (NPWMF) incorporating a model for the contrast sensitivity of the human visual system was introduced for modeling human performance in detection tasks with different viewing angles and white-noise backgrounds by Badano et al. But NPWMF observers do not perform well detection tasks involving complex backgrounds since they do not account for random backgrounds. A channelized-Hotelling observer (CHO) using difference-of-Gaussians (DOG) channels has been shown to track human performance well in detection tasks using lumpy backgrounds. In this work, a CHO with DOG channels, incorporating the model of the human contrast sensitivity, was developed similarly. We call this new observer a contrast-sensitive CHO (CS-CHO). The Barten model was the basis of our human contrast sensitivity model. A scalar was multiplied to the Barten model and varied to control the thresholding effect of the contrast sensitivity on luminance-valued images and hence the performance-prediction ability of the CS-CHO. The performance of the CS-CHO was compared to the average human performance from the psychophysical study by Park et al., where the task was to detect a known Gaussian signal in non-Gaussian distributed lumpy backgrounds. Six different signal-intensity values were used in this study. We chose the free parameter of our model to match the mean human performance in the detection experiment at the strongest signal intensity. Then we compared the model to the human at five different signal-intensity values in order to see if the performance of the CS-CHO matched human performance. Our results indicate that the CS-CHO with the chosen scalar for the contrast sensitivity predicts human performance closely as a function of signal intensity.
Tan, Deborah K L; Tay, Wan Ting; Chan, Cordelia; Tan, Donald T H; Mehta, Jodhbir S
2015-03-01
To evaluate and compare changes in contrast sensitivity and ocular higher-order aberrations (HOAs) after femtosecond lenticule extraction (FLEx) and pseudo small-incision lenticule extraction (SMILE). Singapore National Eye Centre, Singapore. Retrospective case series. Patients had femtosecond lenticule extraction (Group 1) or pseudo small-incision lenticule extraction (Group 2) between March 2010 and December 2011. The main outcome measures were manifest refraction, HOAs, and contrast sensitivity 1, 3, 6, and 12 months postoperatively. Fifty-two consecutive patients (102 eyes) were recruited, 21 patients (42 eyes) in Group 1 and the 31 patients (60 eyes) in Group 2. The uncorrected and corrected distance visual acuities were significantly better in Group 2 than in Group 1 at 12 months (P = .032). There was no significant increase in 3rd- or 4th-order aberrations at 1 year and no significant difference between the 2 groups preoperatively or postoperatively. At 1 year, there was a significant increase in mesopic contrast sensitivity in Group 2 at 1.5 cycles per degree (cpd) (P = .008) that was not found in Group 1, and photopic contrast sensitivity at 6.0 cpd was higher in Group 2 (P = .027). These results indicate that refractive lenticule extraction is safe and effective with no significant induction of HOAs or deterioration in contrast sensitivity at 1 year. Induction of HOAs was not significantly different between both variants of refractive lenticule extraction. However, there was significant improvement in photopic contrast sensitivity after pseudo small-incision lenticule extraction, which persisted through 1 year. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Ding, Zhaofeng; Li, Jinrong; Spiegel, Daniel P.; Chen, Zidong; Chan, Lily; Luo, Guangwei; Yuan, Junpeng; Deng, Daming; Yu, Minbin; Thompson, Benjamin
2016-01-01
Amblyopia is a neurodevelopmental disorder of vision that occurs when the visual cortex receives decorrelated inputs from the two eyes during an early critical period of development. Amblyopic eyes are subject to suppression from the fellow eye, generate weaker visual evoked potentials (VEPs) than fellow eyes and have multiple visual deficits including impairments in visual acuity and contrast sensitivity. Primate models and human psychophysics indicate that stronger suppression is associated with greater deficits in amblyopic eye contrast sensitivity and visual acuity. We tested whether transcranial direct current stimulation (tDCS) of the visual cortex would modulate VEP amplitude and contrast sensitivity in adults with amblyopia. tDCS can transiently alter cortical excitability and may influence suppressive neural interactions. Twenty-one patients with amblyopia and twenty-seven controls completed separate sessions of anodal (a-), cathodal (c-) and sham (s-) visual cortex tDCS. A-tDCS transiently and significantly increased VEP amplitudes for amblyopic, fellow and control eyes and contrast sensitivity for amblyopic and control eyes. C-tDCS decreased VEP amplitude and contrast sensitivity and s-tDCS had no effect. These results suggest that tDCS can modulate visual cortex responses to information from adult amblyopic eyes and provide a foundation for future clinical studies of tDCS in adults with amblyopia. PMID:26763954
Ding, Zhaofeng; Li, Jinrong; Spiegel, Daniel P; Chen, Zidong; Chan, Lily; Luo, Guangwei; Yuan, Junpeng; Deng, Daming; Yu, Minbin; Thompson, Benjamin
2016-01-14
Amblyopia is a neurodevelopmental disorder of vision that occurs when the visual cortex receives decorrelated inputs from the two eyes during an early critical period of development. Amblyopic eyes are subject to suppression from the fellow eye, generate weaker visual evoked potentials (VEPs) than fellow eyes and have multiple visual deficits including impairments in visual acuity and contrast sensitivity. Primate models and human psychophysics indicate that stronger suppression is associated with greater deficits in amblyopic eye contrast sensitivity and visual acuity. We tested whether transcranial direct current stimulation (tDCS) of the visual cortex would modulate VEP amplitude and contrast sensitivity in adults with amblyopia. tDCS can transiently alter cortical excitability and may influence suppressive neural interactions. Twenty-one patients with amblyopia and twenty-seven controls completed separate sessions of anodal (a-), cathodal (c-) and sham (s-) visual cortex tDCS. A-tDCS transiently and significantly increased VEP amplitudes for amblyopic, fellow and control eyes and contrast sensitivity for amblyopic and control eyes. C-tDCS decreased VEP amplitude and contrast sensitivity and s-tDCS had no effect. These results suggest that tDCS can modulate visual cortex responses to information from adult amblyopic eyes and provide a foundation for future clinical studies of tDCS in adults with amblyopia.
Stereo chromatic contrast sensitivity model to blue-yellow gratings.
Yang, Jiachen; Lin, Yancong; Liu, Yun
2016-03-07
As a fundamental metric of human visual system (HVS), contrast sensitivity function (CSF) is typically measured by sinusoidal gratings at the detection of thresholds for psychophysically defined cardinal channels: luminance, red-green, and blue-yellow. Chromatic CSF, which is a quick and valid index to measure human visual performance and various retinal diseases in two-dimensional (2D) space, can not be directly applied into the measurement of human stereo visual performance. And no existing perception model considers the influence of chromatic CSF of inclined planes on depth perception in three-dimensional (3D) space. The main aim of this research is to extend traditional chromatic contrast sensitivity characteristics to 3D space and build a model applicable in 3D space, for example, strengthening stereo quality of 3D images. This research also attempts to build a vision model or method to check human visual characteristics of stereo blindness. In this paper, CRT screen was clockwise and anti-clockwise rotated respectively to form the inclined planes. Four inclined planes were selected to investigate human chromatic vision in 3D space and contrast threshold of each inclined plane was measured with 18 observers. Stimuli were isoluminant blue-yellow sinusoidal gratings. Horizontal spatial frequencies ranged from 0.05 to 5 c/d. Contrast sensitivity was calculated as the inverse function of the pooled cone contrast threshold. According to the relationship between spatial frequency of inclined plane and horizontal spatial frequency, the chromatic contrast sensitivity characteristics in 3D space have been modeled based on the experimental data. The results show that the proposed model can well predicted human chromatic contrast sensitivity characteristics in 3D space.
Fiske-Jackson, A R; Barker, W H J; Eliashar, E; Foy, K; Smith, R K W
2013-01-01
The sensitivity of ultrasonography for the diagnosis of manica flexoria (MF) tears within the digital flexor tendon sheath (DFTS) is lower than for diagnosis of marginal tears of the deep digital flexor tendon (DDFT). Additional diagnostic tools would assist in appropriate decision making for either conservative or surgical management. To evaluate the improvement in lameness of horses with MF or DDFT tears following intrathecal analgesia and to assess the sensitivity and specificity of contrast radiography for the diagnosis of these tears. The case records of horses presented to a referral clinic over a 7-year period that underwent intrathecal diagnostic analgesia, or intrathecal analgesia and contrast radiography, of the DFTS with subsequent tenoscopy were examined. Fifty-three limbs had intrathecal diagnostic analgesia performed and 23 contrast tenograms were assessed in horses undergoing DFTS tenoscopy. Horses with DDFT tears were significantly more likely to respond positively to intrathecal diagnostic analgesia than those with MF tears (P = 0.02). Using contrast radiography, tears of the MF were predicted with an overall sensitivity of 96% and specificity of 80%; marginal tears of the DDFT were predicted with an overall sensitivity of 57% and specificity of 84%. The results of intrathecal analgesia of the DFTS in combination with contrast radiography have a high sensitivity for predicting MF tears. The sensitivity of contrast radiography for predicting tears of the DDFT is lower but the specificity remains high. Contrast radiography performed at the same time as intrathecal analgesia provides useful information regarding the presence of MF tears and DDFT tears, which can assist in the decision of whether to manage the lameness conservatively or with tenoscopic evaluation. © 2012 EVJ Ltd.
Hudnell, H Kenneth
2005-01-01
Blooms of toxigenic organisms have increased in spatial and temporal extent due to human activities and natural forces that alter ecologic habitats and pollute the environment. In aquatic environments, harmful algal blooms pose a risk for human health, the viability of organisms, and the sustainability of ecosystems. The estuarine dinoflagellate, Pfiesteria piscicida, was discovered in the late 1980s at North Carolina State University as a contaminant in fish cultures. P. piscicida was associated with fish death in laboratory aquaria, and illness among laboratory workers who inhaled the mist above aquaria. Both the fish and humans exhibited signs of toxicity. During the 1990s, large-scale mortality among fish and other aquatic organisms was associated with high concentrations of Pfiesteria sp. in estuaries on the eastern seaboard of North America from New York to Texas. Illness among humans was associated with direct exposure to estuaries and exposures to estuarine aerosols around the time of Pfiesteria-related fish kills. This review of the scientific literature on associations between Pfiesteria and human illness identified some of the possible mechanisms of action by which putative Pfiesteria toxins may have caused morbidity. Particular attention was given to the Pfiesteria-associated, human-illness syndrome known as Possible Estuary Associated Syndrome (PEAS). PEAS was characterized by multiple-system symptoms, deficits in neuropsychological tests of cognitive function, and rapid and severe decrements in visual contrast sensitivity (VCS), an indicator of neurologic function in the visual system. PEAS was diagnosed in acute and chronic illness cases, and was reacquired during re-exposure. Rapid normalization of PEAS signs and symptoms was achieved through the use of cholestyramine therapy. Cholestyramine, a non-absorbable polymer, has been used by humans to lower cholesterol levels since it was approved for that use by the U.S. Food and Drug Administration in 1958. When dissolved in water or juice and taken orally, cholestyramine binds with cholesterol, bile acids, and salts in the intestines, causing them to be eliminated rather than reabsorbed with bile during enterohepatic recirculation. Cholestyramine also has been reported to bind and eliminate a variety of toxic substances. The efficacy of cholestyramine therapy in treatment of PEAS supported the hypothesis that PEAS is a biotoxin-associated illness.
Chromatic and achromatic monocular deprivation produce separable changes of eye dominance in adults.
Zhou, Jiawei; Reynaud, Alexandre; Kim, Yeon Jin; Mullen, Kathy T; Hess, Robert F
2017-11-29
Temporarily depriving one eye of its input, in whole or in part, results in a transient shift in eye dominance in human adults, with the patched eye becoming stronger and the unpatched eye weaker. However, little is known about the role of colour contrast in these behavioural changes. Here, we first show that the changes in eye dominance and contrast sensitivity induced by monocular eye patching affect colour and achromatic contrast sensitivity equally. We next use dichoptic movies, customized and filtered to stimulate the two eyes differentially. We show that a strong imbalance in achromatic contrast between the eyes, with no colour content, also produces similar, unselective shifts in eye dominance for both colour and achromatic contrast sensitivity. Interestingly, if this achromatic imbalance is paired with similar colour contrast in both eyes, the shift in eye dominance is selective, affecting achromatic but not chromatic contrast sensitivity and revealing a dissociation in eye dominance for colour and achromatic image content. On the other hand, a strong imbalance in chromatic contrast between the eyes, with no achromatic content, produces small, unselective changes in eye dominance, but if paired with similar achromatic contrast in both eyes, no changes occur. We conclude that perceptual changes in eye dominance are strongly driven by interocular imbalances in achromatic contrast, with colour contrast having a significant counter balancing effect. In the short term, eyes can have different dominances for achromatic and chromatic contrast, suggesting separate pathways at the site of these neuroplastic changes. © 2017 The Author(s).
A gaze-contingent display to study contrast sensitivity under natural viewing conditions
NASA Astrophysics Data System (ADS)
Dorr, Michael; Bex, Peter J.
2011-03-01
Contrast sensitivity has been extensively studied over the last decades and there are well-established models of early vision that were derived by presenting the visual system with synthetic stimuli such as sine-wave gratings near threshold contrasts. Natural scenes, however, contain a much wider distribution of orientations, spatial frequencies, and both luminance and contrast values. Furthermore, humans typically move their eyes two to three times per second under natural viewing conditions, but most laboratory experiments require subjects to maintain central fixation. We here describe a gaze-contingent display capable of performing real-time contrast modulations of video in retinal coordinates, thus allowing us to study contrast sensitivity when dynamically viewing dynamic scenes. Our system is based on a Laplacian pyramid for each frame that efficiently represents individual frequency bands. Each output pixel is then computed as a locally weighted sum of pyramid levels to introduce local contrast changes as a function of gaze. Our GPU implementation achieves real-time performance with more than 100 fps on high-resolution video (1920 by 1080 pixels) and a synthesis latency of only 1.5ms. Psychophysical data show that contrast sensitivity is greatly decreased in natural videos and under dynamic viewing conditions. Synthetic stimuli therefore only poorly characterize natural vision.
Long lasting effects of daily theta burst rTMS sessions in the human amblyopic cortex.
Clavagnier, Simon; Thompson, Benjamin; Hess, Robert F
2013-11-01
It has been reported that a single session of 1 Hz or 10 Hz repetitive transcranial magnetic stimulation (rTMS) of the visual cortex can temporarily improve contrast sensitivity in adults with amblyopia. More recently, continuous theta burst stimulation (cTBS) of the visual cortex has been found to improve contrast sensitivity in observers with normal vision. The aims of this study were to assess whether cTBS of the visual cortex could improve contrast sensitivity in adults with amblyopia and whether repeated sessions of cTBS would lead to more pronounced and/or longer lasting effects. cTBS was delivered to the visual cortex while patients viewed a high contrast stimulus with their non-amblyopic eye. This manipulation was designed to bias the effects of cTBS toward inputs from the amblyopic eye. Contrast sensitivity was measured before and after stimulation. The effects of one cTBS session were measured in five patients and the effects of five consecutive daily sessions were measured in four patients. Three patients were available for follow-up at varying intervals after the final session. cTBS improved amblyopic eye contrast sensitivity to high spatial frequencies (P < 0.05) and there was a cumulative improvement across sessions with asymptotic improvement occurring after 2 daily sessions of stimulation. The contrast sensitivity improvements were stable over a period of up to 78 days. These initial results in a small number of patients indicate the cTBS may allow for enduring visual function improvements in adults with amblyopia. Copyright © 2013 Elsevier Inc. All rights reserved.
Functional changes after treatment of optic pathway paediatric low-grade gliomas
Magli, A; Forte, R; Cinalli, G; Esposito, F; Parisi, S; Capasso, M; Papparella, A
2013-01-01
Objective To evaluate the functional changes after treatment of paediatric optic pathway gliomas (OPGs). Methods All patients with monofocal OPG seen from January 2004 to January 2011 were included. Best corrected visual acuity (BCVA, LogMAR), contrast sensitivity (Hiding-Heidi low-contrast ‘face' test (HH) and Pelli−Robson (PR) contrast sensitivity test), and the Color Test (Ishihara plate) were obtained. Results Twenty-one patients (10 boys and 11 girls with a mean age of 5.5±4.4 years at diagnosis) were included in the study. Neurofibromatosis was present in four cases. Eighteen patients (85.7%) were treated with initial surgery and three patients (14.3%) with initial chemotherapy. BCVA was 0.67±0.8 LogMAR at baseline and 0.62±0.9 LogMAR at last visit (P=0.41). The Color test was not significantly changed at last visit (P=0.62). Contrast sensitivity with the HH test was 9.1±11.1% at baseline and 3.8±6.4% at last visit (P=0.03). Contrast sensitivity with PR chart was 1.33±0.9log at baseline and 1.05±0.7 log at last visit (P=0.005). A reduction in contrast sensitivity at both tests was significantly greater in patients who relapsed than in patients who did not relapse (P=0.001). Conclusion After the treatment of paediatric optic pathway low-grade gliomas, a reduction in contrast sensitivity during follow-up was observed and may be correlated with tumour relapses. PMID:23970029
Visual function of police officers who have undergone refractive surgery.
Hovis, Jeffery K; Ramaswamy, Shankaran
2006-11-01
The visual acuity and contrast sensitivity of police recruits and officers was evaluated in both normal and dim illumination conditions to determine whether officers who have had refractive surgery have compromised night vision. The control group consisted of 76 officers and recruits who have not had refractive surgery and the refractive surgery group consisted of 22 officers and recruits who had refractive surgery. Visual acuity and contrast sensitivity were measured under both room illumination and dim illumination. The room illumination test series included high contrast acuity, low contrast acuity and Pelli-Robson contrast sensitivity. The dim illumination test series included high contrast acuity, low contrast acuity, Pelli-Robson contrast sensitivity, license plate number acuity (with and without glare) and the Mesotest. The general findings were that the refractive surgery group had lower acuity scores on low contrast targets in both room and dim light levels along with a reduction in the Mesotest scores with a glare source compared to the control group. Although refractive surgery police recruits and officers had reduced performance on some vision tests, these reductions were small and it is unlikely that their performance on vision related tasks would be compromised, on average. The major concern is the small number of refractive surgery candidates whose results were well outside the range of the non-surgical candidates. Their vision may be unacceptable for policing. Copyright (c) 2006 Wiley-Liss, Inc.
Do common mechanisms of adaptation mediate color discrimination and appearance? Contrast adaptation
NASA Astrophysics Data System (ADS)
Hillis, James M.; Brainard, David H.
2007-08-01
Are effects of background contrast on color appearance and sensitivity controlled by the same mechanism of adaptation? We examined the effects of background color contrast on color appearance and on color-difference sensitivity under well-matched conditions. We linked the data using Fechner's hypothesis that the rate of apparent stimulus change is proportional to sensitivity and examined a family of parametric models of adaptation. Our results show that both appearance and discrimination are consistent with the same mechanism of adaptation.
Sadeghpour, Naser; Alishiri, Ali Agha; Ajudani, Reza; Khosravi, Mohammad Hossein; Amiri, Mohammad Aghazadeh; Sadeghpour, Omid
2015-01-01
To investigate the effect of tinted filters on visual acuity (VA), contrast sensitivity and patient satisfaction in diabetic retinopathy associated with low vision. In a prospective study, 51 patients with diabetic retinopathy and low vision were assessed. We chose a simple random sampling method and used the patient's files for data collection. LogMAR notations were applied for assessing VA and a contrast sensitivity chart (CSV-1000) was employed for measuring contrast sensitivity. First, measurements were performed without tinted filters and then using them. Appropriate lenses were given to the patients for 2 days, and they were questioned about their satisfaction using them in different places. A total of 20 male and 31 female patients with mean age of 57.3 years participated in the study. With a 527 ± 10 nm filter, mean VA improved significantly (P ≤ 0.05). Using the 527 ± 10 nm and 511 ± 10 nm filters, mean contrast sensitivity was improved significantly at 3 and 6 cycles/degree frequencies (P < 0.05). The effect of other filters on VA and contrast sensitivity was not significant. Patient satisfaction rate was generally high. Tinted filters are able to rehabilitate low-vision patients due to diabetic retinopathy. The 527 ± 10 and 511 ± 10 nm wavelength filters improved contrast sensitivity and the 527 ± 10 nm filter improved VA to some extent. Further investigations are recommended to assess the effect of these filters in patients with other causes of low-vision.
Werner, John S.; Elliott, Sarah L.; Choi, Stacey S.; Doble, Nathan
2009-01-01
PURPOSE To evaluate the influence of spherical aberration on contrast sensitivity using adaptive optics. SETTING Vision Science and Advanced Retinal Imaging Laboratory, Department of Ophthalmology & Vision Science, University of California, Davis Medical Center, Sacramento, California, USA. METHODS Contrast sensitivity at 8 cycles per degree was evaluated using an adaptive optics system that permitted aberrations to be measured with a Shack-Hartman wavefront sensor and controlled by a 109 actuator continuous-surface deformable mirror that was at a plane conjugate to the observer’s pupil. Vertical Gabor patches were viewed through a 6.3 mm diameter pupil conjugate aperture. Contrast sensitivity was measured with the deformable mirror set to produce 1 of 5 spherical aberration profiles (−0.2 to +0.2 μm). Contrast sensitivity over the range of spherical aberration was fitted with a polynomial function. RESULTS Three observers (age 21 to 24 years) participated. The measured total mean spherical aberration resulting from the spherical aberration profiles produced by the deformable mirror was between −0.15 μm and +0.25 μm. The peak contrast sensitivity of this function for the 3 observers combined occurred at +0.06 μm of spherical aberration. The peak contrast sensitivity was also achieved with positive spherical aberration for observer (mean 0.09). CONCLUSION There was intersubject variability in the measurements; however, the average visual performance was best with the introduction of a small positive spherical aberration. PMID:19545813
Naeger, D M; Chang, S D; Kolli, P; Shah, V; Huang, W; Thoeni, R F
2011-01-01
Objective The study compared the sensitivity, specificity, confidence and interpretation time of readers of differing experience in diagnosing acute appendicitis with contrast-enhanced CT using neutral vs positive oral contrast agents. Methods Contrast-enhanced CT for right lower quadrant or right flank pain was performed in 200 patients with neutral and 200 with positive oral contrast including 199 with proven acute appendicitis and 201 with other diagnoses. Test set disease prevalence was 50%. Two experienced gastrointestinal radiologists, one fellow and two first-year residents blindly assessed all studies for appendicitis (2000 readings) and assigned confidence scores (1=poor to 4=excellent). Receiver operating characteristic (ROC) curves were generated. Total interpretation time was recorded. Each reader's interpretation with the two agents was compared using standard statistical methods. Results Average reader sensitivity was found to be 96% (range 91–99%) with positive and 95% (89–98%) with neutral oral contrast; specificity was 96% (92–98%) and 94% (90–97%). For each reader, no statistically significant difference was found between the two agents (sensitivities p-values >0.6; specificities p-values>0.08), in the area under the ROC curve (range 0.95–0.99) or in average interpretation times. In cases without appendicitis, positive oral contrast demonstrated improved appendix identification (average 90% vs 78%) and higher confidence scores for three readers. Average interpretation times showed no statistically significant differences between the agents. Conclusion Neutral vs positive oral contrast does not affect the accuracy of contrast-enhanced CT for diagnosing acute appendicitis. Although positive oral contrast might help to identify normal appendices, we continue to use neutral oral contrast given its other potential benefits. PMID:20959365
Contrast adaptation induced by defocus - a possible error signal for emmetropization?
Ohlendorf, Arne; Schaeffel, Frank
2009-01-01
To describe some features of contrast adaptation as induced by imposed positive or negative defocus. To study its time course and selectivity for the sign of the imposed defocus. Contrast adaptation, CA (here referred to as any change in supra-threshold contrast sensitivity) was induced by presenting a movie to the subjects on a computer screen at 1m distance for 10min, while the right eye was defocused by a trial lens (+4D (n=25); -4D (n=10); -2D (n=11 subjects). The PowerRefractor was used to track accommodation binocularly. Contrast sensitivity at threshold was measured by a method of adjustment with a Gabor patch of 1deg angular subtense, filled with 3.22cyc/deg sine wave grating presented on a computer screen at 1m distance on gray background (33cd/m(2)). Supra-threshold contrast sensitivity was quantified by an interocular contrast matching task, in which the subject had to match the contrast of the sine wave grating seen with the right eye with the contrast of a grating with fixed contrast of 0.1. (1) Contrast sensitivity thresholds were not lowered by previous viewing of defocused movies. (2) By wearing positive lenses, the supra-threshold contrast sensitivity in the right eye was raised by about 30% and remained elevated for at least 2min until baseline was reached after about 5min. (3) CA was induced only by positive, but not by negative lenses, even after the distance of the computer screen was taken into account (1m, equivalent to +1D). In five subjects, binocular accommodation was tracked over the full adaptation period. Accommodation appeared to focus the eye not wearing a lens, but short transient switches in focus to the lens wearing eye could not be entirely excluded. Transient contrast adaptation was found at 3.22cyc/deg when positive lenses were worn but not with negative lenses. This asymmetry is intriguing. While it may represent an epiphenomenon of physiological optics, further experiments are necessary to determine whether it could also trace back to differences in CA with defocus of different sign.
Khoshnevis, Matin; Nguyen-Cuu, Jeannie; Sebag, J
2016-12-01
To describe the onset of floaters and reduction in contrast sensitivity (CS) following successful pharmacologic vitreolysis with ocriplasmin for the treatment of vitreo-macular traction (VMT) in a patient with previously normal CS. A 65-year-old woman with a past ocular history of normal visual acuity (VA = 20/26) and contrast sensitivity (1.81% Weber) presents with a 4-month history of distortions. VA decreased to 20/40 and Optical Coherence Tomography (OCT) demonstrated VMT. Pharmacologic vitreolysis was performed with intravitreal ocriplasmin. Ten weeks later the patient complained of floaters and was found to have a PVD and complete resolution of VMT. VA was still 20/40, but contrast sensitivity decreased by more than 100% to 3.77%Weber. After 6 months of attempted coping, this did not improve, so limited vitrectomy was performed. Post-operative VA = 20/26 and CS improved by 46% from 3.77%W to 2.03%W (normal). and importance: This case highlights a little discussed consequence of PVD induction by successful pharmacologic vitreolysis - the development of clinically significant floaters. The resulting reduction of contrast sensitivity was normalized by limited vitrectomy, strongly suggesting that the detached vitreous was the cause.
Internal noise sources limiting contrast sensitivity.
Silvestre, Daphné; Arleo, Angelo; Allard, Rémy
2018-02-07
Contrast sensitivity varies substantially as a function of spatial frequency and luminance intensity. The variation as a function of luminance intensity is well known and characterized by three laws that can be attributed to the impact of three internal noise sources: early spontaneous neural activity limiting contrast sensitivity at low luminance intensities (i.e. early noise responsible for the linear law), probabilistic photon absorption at intermediate luminance intensities (i.e. photon noise responsible for de Vries-Rose law) and late spontaneous neural activity at high luminance intensities (i.e. late noise responsible for Weber's law). The aim of this study was to characterize how the impact of these three internal noise sources vary with spatial frequency and determine which one is limiting contrast sensitivity as a function of luminance intensity and spatial frequency. To estimate the impact of the different internal noise sources, the current study used an external noise paradigm to factorize contrast sensitivity into equivalent input noise and calculation efficiency over a wide range of luminance intensities and spatial frequencies. The impact of early and late noise was found to drop linearly with spatial frequency, whereas the impact of photon noise rose with spatial frequency due to ocular factors.
Guo, Xinxing; Kong, Xiangbin; Huang, Rui; Jin, Ling; Ding, Xiaohu; He, Mingguang; Liu, Xing; Patel, Mehul Chimanlal; Congdon, Nathan G
2014-01-07
We evaluated the effect of ginkgo biloba extract on visual field defect and contrast sensitivity in a Chinese cohort with normal tension glaucoma. In this prospective, randomized, placebo-controlled crossover study, patients newly diagnosed with normal tension glaucoma, either in a tertiary glaucoma clinic (n = 5) or in a cohort undergoing routine general physical examinations in a primary care clinic (n = 30), underwent two 4-week phases of treatment, separated by a washout period of 8 weeks. Randomization determined whether ginkgo biloba extract (40 mg, 3 times per day) or placebo (identical-appearing tablets) was received first. Primary outcomes were change in contrast sensitivity and mean deviation on 24-2 SITA standard visual field testing, while secondary outcomes included IOP and self-reported adverse events. A total of 35 patients with mean age 63.7 (6.5) years were randomized to the ginkgo biloba extract-placebo (n = 18) or the placebo-ginkgo biloba extract (n = 17) sequence. A total of 28 patients (80.0%, 14 in each group) who completed testing did not differ at baseline in age, sex, visual field mean deviation, contrast sensitivity, IOP, or blood pressure. Changes in visual field and contrast sensitivity did not differ by treatment received or sequence (P > 0.2 for all). Power to have detected a difference in mean defect as large as previously reported was 80%. In contrast to some previous reports, ginkgo biloba extract treatment had no effect on mean defect or contrast sensitivity in this group of normal tension glaucoma patients. (http://www.chictr.org number, ChiCTR-TRC-08000724).
Non-contrast MRI diagnosis of adhesive capsulitis of the shoulder.
Chi, Andrew S; Kim, John; Long, Suzanne S; Morrison, William B; Zoga, Adam C
To investigate non-contrast MRI findings of clinical adhesive capsulitis. 31 non-contrast, non-arthrographic, shoulder MRIs were evaluated for coracohumeral ligament thickness, rotator interval infiltration, and axillary recess thickening/edema. In detection of adhesive capsulitis, sensitivity is 76.7% and specificity is 53.3% for coracohumeral ligament thickening, sensitivity is 66.7% and specificity is 55.2% for coracohumeral ligament thickening and rotator interval infiltration, and sensitivity is 23.3% and specificity is 86.7% for coracohumeral ligament thickening, rotator interval infiltration, and axillary recess thickening/edema. Adhesive capsulitis can be accurately diagnosed on non-contrast MRI shoulder examinations with appropriate clinical criteria without direct MR arthrography. Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
MacDonald, Lawrence R.; Wang, Carolyn L.; Eissa, Marna
2012-10-15
Purpose: To characterize the relationship between lesion detection sensitivity and injected activity as a function of lesion size and contrast on the PEM (positron emission mammography) Flex Solo II scanner using phantom experiments. Methods: Phantom lesions (spheres 4, 8, 12, 16, and 20 mm diameter) were randomly located in uniform background. Sphere activity concentrations were 3 to 21 times the background activity concentration (BGc). BGc was a surrogate for injected activity; BGc ranged from 0.44-4.1 kBq/mL, corresponding to 46-400 MBq injections. Seven radiologists read 108 images containing zero, one, or two spheres. Readers used a 5-point confidence scale to scoremore » the presence of spheres. Results: Sensitivity was 100% for lesions {>=}12 mm under all conditions except for one 12 mm sphere with the lowest contrast and lowest BGc (60% sensitivity). Sensitivity was 100% for 8 mm spheres when either contrast or BGc was high, and 100% for 4 mm spheres only when both contrast and BGc were highest. Sphere contrast recovery coefficients (CRC) were 49%, 34%, 26%, 14%, and 2.8% for the largest to smallest spheres. Cumulative specificity was 98%. Conclusions: Phantom lesion detection sensitivity depends more on sphere size and contrast than on BGc. Detection sensitivity remained {>=}90% for injected activities as low as 100 MBq, for lesions {>=}8 mm. Low CRC in 4 mm objects results in moderate detection sensitivity even for 400 MBq injected activity, making it impractical to optimize injected activity for such lesions. Low CRC indicates that when lesions <8 mm are observed on PEM images they are highly tracer avid with greater potential of clinical significance. High specificity (98%) suggests that image statistical noise does not lead to false positive findings. These results apply to the 85 mm thick object used to obtain them; lesion detectability should be better (worse) for thinner (thicker) objects based on the reduced (increased) influence of photon attenuation.« less
High contrast sensitivity for visually guided flight control in bumblebees.
Chakravarthi, Aravin; Kelber, Almut; Baird, Emily; Dacke, Marie
2017-12-01
Many insects rely on vision to find food, to return to their nest and to carefully control their flight between these two locations. The amount of information available to support these tasks is, in part, dictated by the spatial resolution and contrast sensitivity of their visual systems. Here, we investigate the absolute limits of these visual properties for visually guided position and speed control in Bombus terrestris. Our results indicate that the limit of spatial vision in the translational motion detection system of B. terrestris lies at 0.21 cycles deg -1 with a peak contrast sensitivity of at least 33. In the perspective of earlier findings, these results indicate that bumblebees have higher contrast sensitivity in the motion detection system underlying position control than in their object discrimination system. This suggests that bumblebees, and most likely also other insects, have different visual thresholds depending on the behavioral context.
Study of the semileptonic charm decays D(0)-->pi(-)l(+)nu and D(0)-->K(-)l(+)nu.
Huang, G S; Miller, D H; Pavlunin, V; Sanghi, B; Shibata, E I; Shipsey, I P J; Adams, G S; Chasse, M; Cummings, J P; Danko, I; Napolitano, J; Cronin-Hennessy, D; Park, C S; Park, W; Thayer, J B; Thorndike, E H; Coan, T E; Gao, Y S; Liu, F; Stroynowski, R; Artuso, M; Boulahouache, C; Blusk, S; Butt, J; Dambasuren, E; Dorjkhaidav, O; Menaa, N; Mountain, R; Muramatsu, H; Nandakumar, R; Redjimi, R; Sia, R; Skwarnicki, T; Stone, S; Wang, J C; Zhang, K; Mahmood, A H; Csorna, S E; Bonvicini, G; Cinabro, D; Dubrovin, M; Bornheim, A; Lipeles, E; Pappas, S P; Weinstein, A J; Briere, R A; Chen, G P; Ferguson, T; Tatishvili, G; Vogel, H; Watkins, M E; Adam, N E; Alexander, J P; Berkelman, K; Cassel, D G; Duboscq, J E; Ecklund, K M; Ehrlich, R; Fields, L; Galik, R S; Gibbons, L; Gittelman, B; Gray, R; Gray, S W; Hartill, D L; Heltsley, B K; Hertz, D; Hsu, L; Jones, C D; Kandaswamy, J; Kreinick, D L; Kuznetsov, V E; Mahlke-Krüger, H; Meyer, T O; Onyisi, P U E; Patterson, J R; Pedlar, T K; Peterson, D; Pivarski, J; Riley, D; Rosner, J L; Ryd, A; Sadoff, A J; Schwarthoff, H; Shepherd, M R; Sun, W M; Thayer, J G; Urner, D; Wilksen, T; Weinberger, M; Athar, S B; Avery, P; Breva-Newell, L; Patel, R; Potlia, V; Stoeck, H; Yelton, J; Rubin, P; Cawlfield, C; Eisenstein, B I; Gollin, G D; Karliner, I; Kim, D; Lowrey, N; Naik, P; Sedlack, C; Selen, M; Thaler, J J; Williams, J; Wiss, J; Edwards, K W; Besson, D; Gao, K Y; Gong, D T; Kubota, Y; Li, S Z; Poling, R; Scott, A W; Smith, A; Stepaniak, C J; Urheim, J; Metreveli, Z; Seth, K K; Tomaradze, A; Zweber, P; Ernst, J; Arms, K; Gan, K K; Severini, H; Skubic, P; Asner, D M; Dytman, S A; Mehrabyan, S; Mueller, J A; Savinov, V; Li, Z; Lopez, A; Mendez, H; Ramirez, J
2005-01-14
We investigate the decays D(0)-->pi(-)l(+)nu and D(0)-->K(-)l(+)nu, where l is e or mu, using approximately 7 fb(-1) of data collected with the CLEO III detector. We find R(0) identical with B(D(0)-->pi(-)e(+)nu)/B(D(0)-->K(-)e(+)nu)=0.082+/-0.006+/-0.005. Fits to the kinematic distributions of the data provide parameters describing the form factor of each mode. Combining the form factor results and R(0) gives |f(pi)(+)(0)|(2)|V(cd)|(2)/|f(K)(+)(0)|(2)|V(cs)|(2)=0.038(+0.006+0.005)(-0.007-0.003).
Cronin-Hennessy, D; Gao, K Y; Gong, D T; Hietala, J; Kubota, Y; Klein, T; Lang, B W; Poling, R; Scott, A W; Smith, A; Zweber, P; Dobbs, S; Metreveli, Z; Seth, K K; Tomaradze, A; Ernst, J; Severini, H; Dytman, S A; Love, W; Savinov, V; Aquines, O; Li, Z; Lopez, A; Mehrabyan, S; Mendez, H; Ramirez, J; Huang, G S; Miller, D H; Pavlunin, V; Sanghi, B; Shipsey, I P J; Xin, B; Adams, G S; Anderson, M; Cummings, J P; Danko, I; Napolitano, J; He, Q; Insler, J; Muramatsu, H; Park, C S; Thorndike, E H; Yang, F; Coan, T E; Gao, Y S; Liu, F; Artuso, M; Blusk, S; Butt, J; Li, J; Menaa, N; Mountain, R; Nisar, S; Randrianarivony, K; Redjimi, R; Sia, R; Skwarnicki, T; Stone, S; Wang, J C; Zhang, K; Csorna, S E; Bonvicini, G; Cinabro, D; Dubrovin, M; Lincoln, A; Asner, D M; Edwards, K W; Briere, R A; Brock, I; Chen, J; Ferguson, T; Tatishvili, G; Vogel, H; Watkins, M E; Rosner, J L; Adam, N E; Alexander, J P; Berkelman, K; Cassel, D G; Duboscq, J E; Ecklund, K M; Ehrlich, R; Fields, L; Gibbons, L; Gray, R; Gray, S W; Hartill, D L; Heltsley, B K; Hertz, D; Jones, C D; Kandaswamy, J; Kreinick, D L; Kuznetsov, V E; Mahlke-Krüger, H; Onyisi, P U E; Patterson, J R; Peterson, D; Pivarski, J; Riley, D; Ryd, A; Sadoff, A J; Schwarthoff, H; Shi, X; Stroiney, S; Sun, W M; Wilksen, T; Weinberger, M; Athar, S B; Patel, R; Potlia, V; Yelton, J; Rubin, P; Cawlfield, C; Eisenstein, B I; Karliner, I; Kim, D; Lowrey, N; Naik, P; Sedlack, C; Selen, M; White, E J; Wiss, J; Shepherd, M R; Besson, D; Pedlar, T K
2008-06-27
By using 1.8x10{6} DDpairs, we have measured B(D{0}-->pi{-}e{+}nu{e})=0.299(11)(9)%, B(D{+}-->pi{0}e{+}nu{e})=0.373(22)(13)%, B(D{0}-->K{-}e{+}nu{e})=3.56(3)(9)%, and B(D{+}-->K{0}e{+}nu{e})=8.53(13)(23)% and have studied the q;{2} dependence of the form factors. By combining our results with recent lattice calculations, we obtain |V{cd}|=0.217(9)(4)(23) and |V{cs}|=1.015(10)(11)(106).
Pixels, people, perception, pet peeves, and possibilities: a look at displays
NASA Astrophysics Data System (ADS)
Task, H. Lee
2007-04-01
This year marks the 35 th anniversary of the Visually Coupled Systems symposium held at Brooks Air Force Base, San Antonio, Texas in November of 1972. This paper uses the proceedings of the 1972 VCS symposium as a guide to address several topics associated primarily with helmet-mounted displays, systems integration and the human-machine interface. Specific topics addressed include monocular and binocular helmet-mounted displays (HMDs), visor projection HMDs, color HMDs, system integration with aircraft windscreens, visual interface issues and others. In addition, this paper also addresses a few mysteries and irritations (pet peeves) collected over the past 35+ years of experience in the display and display related areas.
A Sensitive Dynamic and Active Pixel Vision Sensor for Color or Neural Imaging Applications.
Moeys, Diederik Paul; Corradi, Federico; Li, Chenghan; Bamford, Simeon A; Longinotti, Luca; Voigt, Fabian F; Berry, Stewart; Taverni, Gemma; Helmchen, Fritjof; Delbruck, Tobi
2018-02-01
Applications requiring detection of small visual contrast require high sensitivity. Event cameras can provide higher dynamic range (DR) and reduce data rate and latency, but most existing event cameras have limited sensitivity. This paper presents the results of a 180-nm Towerjazz CIS process vision sensor called SDAVIS192. It outputs temporal contrast dynamic vision sensor (DVS) events and conventional active pixel sensor frames. The SDAVIS192 improves on previous DAVIS sensors with higher sensitivity for temporal contrast. The temporal contrast thresholds can be set down to 1% for negative changes in logarithmic intensity (OFF events) and down to 3.5% for positive changes (ON events). The achievement is possible through the adoption of an in-pixel preamplification stage. This preamplifier reduces the effective intrascene DR of the sensor (70 dB for OFF and 50 dB for ON), but an automated operating region control allows up to at least 110-dB DR for OFF events. A second contribution of this paper is the development of characterization methodology for measuring DVS event detection thresholds by incorporating a measure of signal-to-noise ratio (SNR). At average SNR of 30 dB, the DVS temporal contrast threshold fixed pattern noise is measured to be 0.3%-0.8% temporal contrast. Results comparing monochrome and RGBW color filter array DVS events are presented. The higher sensitivity of SDAVIS192 make this sensor potentially useful for calcium imaging, as shown in a recording from cultured neurons expressing calcium sensitive green fluorescent protein GCaMP6f.
García-Domene, M C; Luque, M J; Díez-Ajenjo, M A; Desco-Esteban, M C; Artigas, J M
2018-02-01
To analyse the relationship between the choroidal thickness and the visual perception of patients with high myopia but without retinal damage. All patients underwent ophthalmic evaluation including a slit lamp examination and dilated ophthalmoscopy, subjective refraction, best corrected visual acuity, axial length, optical coherence tomography, contrast sensitivity function and sensitivity of the visual pathways. We included eleven eyes of subjects with high myopia. There are statistical correlations between choroidal thickness and almost all the contrast sensitivity values. The sensitivity of magnocellular and koniocellular pathways is the most affected, and the homogeneity of the sensibility of the magnocellular pathway depends on the choroidal thickness; when the thickness decreases, the sensitivity impairment extends from the center to the periphery of the visual field. Patients with high myopia without any fundus changes have visual impairments. We have found that choroidal thickness correlates with perceptual parameters such as contrast sensitivity or mean defect and pattern standard deviation of the visual fields of some visual pathways. Our study shows that the magnocellular and koniocellular pathways are the most affected, so that these patients have impairment in motion perception and blue-yellow contrast perception. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Penetrating Colorectal Injuries: Diagnostic Performance of Multidetector CT with Trajectography.
Dreizin, David; Boscak, Alexis R; Anstadt, Michael J; Tirada, Nikki; Chiu, William C; Munera, Felipe; Bodanapally, Uttam K; Hornick, Michael; Stein, Deborah M
2016-12-01
Purpose To determine the diagnostic performance of multidetector computed tomography (CT) with trajectography for penetrating colorectal injuries. Materials and Methods This institutional review board-approved and HIPAA-compliant study was a 6-year blinded retrospective review by two independent readers of 182 consecutive patients who preoperatively underwent 40- or 64-row multidetector CT for penetrating torso trauma below the diaphragm and had surgically confirmed findings. Colorectal perforation was present in 42 patients. Trajectory analysis with postprocessing software was used for all studies. Additional signs evaluated were rectal contrast agent leak, collections of extruded fecal material, mural defect, wall thickening, abnormal enhancement, free fluid or stranding, and free air. The quality of the colorectal contrast agent administration was recorded. Sensitivity, specificity, predictive values, areas under the receiver operating characteristic curves (AUCs), and Cohen κ were determined. Results In patients with rectal contrast agent administration (n = 151), AUCs were 0.90-0.91, which indicated excellent accuracy. Trajectory was sensitive (88%-91%). For single wounds (n = 104), sensitivity of trajectory was 96% for both readers, but was only 80% for multiple wounds (n = 47). Contrast agent leak was highly specific (96%-98%), but insensitive (42%-46%). Improved diagnostic performance was observed in patients with poor colonic distension or opacification. Accuracy remained high (AUC, 0.86-0.99) in the group without rectal contrast agent administration (n = 31). Conclusion Trajectory had excellent sensitivity, while rectal contrast agent leak was specific but insensitive. Sensitivity of trajectory was lower for multiple wounds. Accuracy remained high in patients without rectal contrast agent administration. © RSNA, 2016.
Visible Contrast Energy Metrics for Detection and Discrimination
NASA Technical Reports Server (NTRS)
Ahumada, Albert; Watson, Andrew
2013-01-01
Contrast energy was proposed by Watson, Robson, & Barlow as a useful metric for representing luminance contrast target stimuli because it represents the detectability of the stimulus in photon noise for an ideal observer. Like the eye, the ear is a complex transducer system, but relatively simple sound level meters are used to characterize sounds. These meters provide a range of frequency sensitivity functions and integration times depending on the intended use. We propose here the use of a range of contrast energy measures with different spatial frequency contrast sensitivity weightings, eccentricity sensitivity weightings, and temporal integration times. When detection threshold are plotting using such measures, the results show what the eye sees best when these variables are taken into account in a standard way. The suggested weighting functions revise the Standard Spatial Observer for luminance contrast detection and extend it into the near periphery. Under the assumption that the detection is limited only by internal noise, discrimination performance can be predicted by metrics based on the visible energy of the difference images
Fast packet switching algorithms for dynamic resource control over ATM networks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsang, R.P.; Keattihananant, P.; Chang, T.
1996-12-01
Real-time continuous media traffic, such as digital video and audio, is expected to comprise a large percentage of the network load on future high speed packet switch networks such as ATM. A major feature which distinguishes high speed networks from traditional slower speed networks is the large amount of data the network must process very quickly. For efficient network usage, traffic control mechanisms are essential. Currently, most mechanisms for traffic control (such as flow control) have centered on the support of Available Bit Rate (ABR), i.e., non real-time, traffic. With regard to ATM, for ABR traffic, two major types ofmore » schemes which have been proposed are rate- control and credit-control schemes. Neither of these schemes are directly applicable to Real-time Variable Bit Rate (VBR) traffic such as continuous media traffic. Traffic control for continuous media traffic is an inherently difficult problem due to the time- sensitive nature of the traffic and its unpredictable burstiness. In this study, we present a scheme which controls traffic by dynamically allocating/de- allocating resources among competing VCs based upon their real-time requirements. This scheme incorporates a form of rate- control, real-time burst-level scheduling and link-link flow control. We show analytically potential performance improvements of our rate- control scheme and present a scheme for buffer dimensioning. We also present simulation results of our schemes and discuss the tradeoffs inherent in maintaining high network utilization and statistically guaranteeing many users` Quality of Service.« less
Is Suppression Just Normal Dichoptic Masking? Suprathreshold Considerations.
Reynaud, Alexandre; Hess, Robert F
2016-10-01
Amblyopic patients have a deficit in visual acuity and contrast sensitivity in their amblyopic eye as well as suppression of the amblyopic eye input under binocular viewing conditions. In this study we wanted to assess the origin of the amblyopic suppression by studying the contrast perception of the amblyopic eye at suprathreshold levels under binocular and monocular viewing. Using a suprathreshold contrast matching task in which the reference and target stimuli were presented to different eyes either simultaneously or successively, we measured interocular contrast matching in 10 controls and 11 amblyopes (mean age 35 ± 15; 5 strabismics; 3 anisometropes; 3 mixed). This was then used as an index of the binocular balance across spatial frequency and compared against the contrast sensitivity ratio measured with the same stimuli. We observed that binocular matching becomes more imbalanced at high spatial frequency for amblyopes, compared with controls; that this imbalance did not depend in either group on whether the stimuli were presented simultaneously or successively; and that for both modes of presentation the matching balance correlates well with the interocular contrast sensitivity ratio (mean correlation coefficient of the slopes R = 0.7125). The results from our amblyopes show comparable losses of contrast perception at and above threshold under these binocular viewing conditions across a wide spatial frequency range, much stronger than that observed for our controls. This occurs under conditions in which there should be no dichoptic masking. Furthermore, the matching contrast could be well predicted by the monocular contrast sensitivity. Altogether, this suggests that amblyopic suppression cannot be explained by normal dichoptic masking but rather an attenuation of the input.
Visual resolution and contrast sensitivity in two benthic sharks.
Ryan, Laura A; Hart, Nathan S; Collin, Shaun P; Hemmi, Jan M
2016-12-15
Sharks have long been described as having 'poor' vision. They are cone monochromats and anatomical estimates suggest they have low spatial resolution. However, there are no direct behavioural measurements of spatial resolution or contrast sensitivity. This study estimates contrast sensitivity and spatial resolution of two species of benthic sharks, the Port Jackson shark, Heterodontus portusjacksoni, and the brown-banded bamboo shark, Chiloscyllium punctatum, by recording eye movements in response to optokinetic stimuli. Both species tracked moving low spatial frequency gratings with weak but consistent eye movements. Eye movements ceased at 0.38 cycles per degree, even for high contrasts, suggesting low spatial resolution. However, at lower spatial frequencies, eye movements were elicited by low contrast gratings, 1.3% and 2.9% contrast in H portusjacksoni and C. punctatum, respectively. Contrast sensitivity was higher than in other vertebrates with a similar spatial resolving power, which may reflect an adaptation to the relatively low contrast encountered in aquatic environments. Optokinetic gain was consistently low and neither species stabilised the gratings on their retina. To check whether restraining the animals affected their optokinetic responses, we also analysed eye movements in free-swimming C. punctatum We found no eye movements that could compensate for body rotations, suggesting that vision may pass through phases of stabilisation and blur during swimming. As C. punctatum is a sedentary benthic species, gaze stabilisation during swimming may not be essential. Our results suggest that vision in sharks is not 'poor' as previously suggested, but optimised for contrast detection rather than spatial resolution. © 2016. Published by The Company of Biologists Ltd.
Brightness discrimination and contrast sensitivity in chronic glaucoma--a clinical study.
Teoh, S L; Allan, D; Dutton, G N; Foulds, W S
1990-04-01
The visual acuity, the difference in sensitivity of the two eyes to light (brightness ratio), and contrast sensitivity were assessed in 28 patients with chronic open angle glaucoma and compared with those of 41 normal controls of similar ages and visual acuity. The results obtained were related to the results of Tübingen visual field analysis in patients with glaucoma. Twenty-four of the 28 glaucoma patients (86%) had a significant disparity in brightness ratio between the two eyes. This was found to match the frequency of visual field loss. Moreover, there was a significant relationship between the interocular differences in brightness sense and the difference in the degree of visual field loss between the two eyes. Of the glaucoma patients 39% had sum contrast sensitivities outside the normal range for age-matched normal controls. No significant correlation was found between the interocular difference in brightness sense and the visual acuity or the interocular difference in sum contrast sensitivity. It is concluded that, in the presence of a normal visual acuity, the brightness ratio test warrants evaluation as a potential screening test for chronic open angle glaucoma.
Rucker, F. J.; Osorio, D.
2009-01-01
Longitudinal chromatic aberration is a well-known imperfection of visual optics, but the consequences in natural conditions, and for the evolution of receptor spectral sensitivities are less well understood. This paper examines how chromatic aberration affects image quality in the middle-wavelength sensitive (M-) cones, viewing broad-band spectra, over a range of spatial frequencies and focal planes. We also model the effects on M-cone contrast of moving the M-cone fundamental relative to the long- and middle-wavelength (L- and M-cone) fundamentals, while the eye is accommodated at different focal planes or at a focal plane that maximizes luminance contrast. When the focal plane shifts towards longer (650 nm) or shorter wavelengths (420 nm) the effects on M-cone contrast are large: longitudinal chromatic aberration causes total loss of M-cone contrast above 10 to 20 c/d. In comparison, the shift of the M-cone fundamental causes smaller effects on M-cone contrast. At 10 c/d a shift in the peak of the M-cone spectrum from 560 nm to 460 nm decreases M-cone contrast by 30%, while a 10 nm blue-shift causes only a minor loss of contrast. However, a noticeable loss of contrast may be seen if the eye is focused at focal planes other than that which maximizes luminance contrast. The presence of separate long- and middle-wavelength sensitive cones therefore has a small, but not insignificant cost to the retinal image via longitudinal chromatic aberration. This aberration may therefore be a factor limiting evolution of visual pigments and trichromatic color vision. PMID:18639571
Kim, Jae Heon; Sun, Hwa Yeon; Hwang, Jiyoung; Hong, Seong Sook; Cho, Yong Jin; Doo, Seung Whan; Yang, Won Jae; Song, Yun Seob
2016-10-12
The aim of this study was to investigate the diagnostic accuracy of contrast-enhanced computed tomography (CT) and contrast-enhanced magnetic resonance imaging (MRI) of small renal masses in real practice. Contrast-enhanced CT and MRI were performed between February 2008 and February 2013 on 68 patients who had suspected small (≤4 cm) renal cell carcinoma (RCC) based on ultrasonographic measurements. CT and MRI radiographs were reviewed, and the findings of small renal masses were re-categorized into five dichotomized scales by the same two radiologists who had interpreted the original images. Receiver operating characteristics curve analysis was performed, and sensitivity and specificity were determined. Among the 68 patients, 60 (88.2 %) had RCC and eight had benign disease. The diagnostic accuracy rates of contrast-enhanced CT and MRI were 79.41 and 88.23 %, respectively. Diagnostic accuracy was greater when using contrast-enhanced MRI because too many masses (67.6 %) were characterized as "4 (probably solid cancer) or 5 (definitely solid cancer)." The sensitivity of contrast-enhanced CT and MRI for predicting RCC were 79.7 and 88.1 %, respectively. The specificities of contrast-enhanced CT and MRI for predicting RCC were 44.4 and 33.3 %, respectively. Fourteen diagnoses (20.5 %) were missed or inconsistent compared with the final pathological diagnoses. One appropriate nephroureterectomy and five unnecessary percutaneous biopsies were performed for RCC. Seven unnecessary partial nephrectomies were performed for benign disease. Although contrast-enhanced CT and MRI showed high sensitivity for detecting small renal masses, specificity remained low.
Spatial contrast sensitivity - Effects of age, test-retest, and psychophysical method
NASA Technical Reports Server (NTRS)
Higgins, Kent E.; Jaffe, Myles J.; Caruso, Rafael C.; Demonasterio, Francisco M.
1988-01-01
Two different psychophysical methods were used to test the spatial contrast sensitivity in normal subjects from five age groups. The method of adjustment showed a decline in sensitivity with increasing age at all spatial frequencies, while the forced-choice procedure showed an age-related decline predominantly at high spatial frequencies. It is suggested that a neural component is responsible for this decline.
CEOS Ocean Variables Enabling Research and Applications for Geo (COVERAGE)
NASA Astrophysics Data System (ADS)
Tsontos, V. M.; Vazquez, J.; Zlotnicki, V.
2017-12-01
The CEOS Ocean Variables Enabling Research and Applications for GEO (COVERAGE) initiative seeks to facilitate joint utilization of different satellite data streams on ocean physics, better integrated with biological and in situ observations, including near real-time data streams in support of oceanographic and decision support applications for societal benefit. COVERAGE aligns with programmatic objectives of CEOS (the Committee on Earth Observation Satellites) and the missions of GEO-MBON (Marine Biodiversity Observation Network) and GEO-Blue Planet, which are to advance and exploit synergies among the many observational programs devoted to ocean and coastal waters. COVERAGE is conceived of as 3 year pilot project involving international collaboration. It focuses on implementing technologies, including cloud based solutions, to provide a data rich, web-based platform for integrated ocean data delivery and access: multi-parameter observations, easily discoverable and usable, organized by disciplines, available in near real-time, collocated to a common grid and including climatologies. These will be complemented by a set of value-added data services available via the COVERAGE portal including an advanced Web-based visualization interface, subsetting/extraction, data collocation/matchup and other relevant on demand processing capabilities. COVERAGE development will be organized around priority use cases and applications identified by GEO and agency partners. The initial phase will be to develop co-located 25km products from the four Ocean Virtual Constellations (VCs), Sea Surface Temperature, Sea Level, Ocean Color, and Sea Surface Winds. This aims to stimulate work among the ocean VCs while developing products and system functionality based on community recommendations. Such products as anomalies from a time mean, would build on the theme of applications with a relevance to CEOS/GEO mission and vision. Here we provide an overview of the COVERAGE initiative with an emphasis on international collaborative aspects entailed with the intent of soliciting community feedback as we develop and implement
Body temperature sensitive micelles for MRI enhancement.
Zhu, Xiaolei; Chen, Shizhen; Luo, Qing; Ye, Chaohui; Liu, Maili; Zhou, Xin
2015-06-04
A novel thermo-sensitive micelle contrast agent and its enhancement of MRI contrast with temperature are reported. The morphology changes sharply near 37 °C, resulting in a significant amplification of the CEST signal. This enables detection of small changes in body temperature.
Bernstein, Ally Leigh; Dhanantwari, Amar; Jurcova, Martina; Cheheltani, Rabee; Naha, Pratap Chandra; Ivanc, Thomas; Shefer, Efrat; Cormode, David Peter
2016-01-01
Computed tomography is a widely used medical imaging technique that has high spatial and temporal resolution. Its weakness is its low sensitivity towards contrast media. Iterative reconstruction techniques (ITER) have recently become available, which provide reduced image noise compared with traditional filtered back-projection methods (FBP), which may allow the sensitivity of CT to be improved, however this effect has not been studied in detail. We scanned phantoms containing either an iodine contrast agent or gold nanoparticles. We used a range of tube voltages and currents. We performed reconstruction with FBP, ITER and a novel, iterative, modal-based reconstruction (IMR) algorithm. We found that noise decreased in an algorithm dependent manner (FBP > ITER > IMR) for every scan and that no differences were observed in attenuation rates of the agents. The contrast to noise ratio (CNR) of iodine was highest at 80 kV, whilst the CNR for gold was highest at 140 kV. The CNR of IMR images was almost tenfold higher than that of FBP images. Similar trends were found in dual energy images formed using these algorithms. In conclusion, IMR-based reconstruction techniques will allow contrast agents to be detected with greater sensitivity, and may allow lower contrast agent doses to be used. PMID:27185492
High-resolution contrast-enhanced optical coherence tomography in mice retinae
NASA Astrophysics Data System (ADS)
Sen, Debasish; SoRelle, Elliott D.; Liba, Orly; Dalal, Roopa; Paulus, Yannis M.; Kim, Tae-Wan; Moshfeghi, Darius M.; de la Zerda, Adam
2016-06-01
Optical coherence tomography (OCT) is a noninvasive interferometric imaging modality providing anatomical information at depths of millimeters and a resolution of micrometers. Conventional OCT images limit our knowledge to anatomical structures alone, without any contrast enhancement. Therefore, here we have, for the first time, optimized an OCT-based contrast-enhanced imaging system for imaging single cells and blood vessels in vivo inside the living mouse retina at subnanomolar sensitivity. We used bioconjugated gold nanorods (GNRs) as exogenous OCT contrast agents. Specifically, we used anti-mouse CD45 coated GNRs to label mouse leukocytes and mPEG-coated GNRs to determine sensitivity of GNR detection in vivo inside mice retinae. We corroborated OCT observations with hyperspectral dark-field microscopy of formalin-fixed histological sections. Our results show that mouse leukocytes that otherwise do not produce OCT contrast can be labeled with GNRs leading to significant OCT intensity equivalent to a 0.5 nM GNR solution. Furthermore, GNRs injected intravenously can be detected inside retinal blood vessels at a sensitivity of ˜0.5 nM, and GNR-labeled cells injected intravenously can be detected inside retinal capillaries by enhanced OCT contrast. We envision the unprecedented resolution and sensitivity of functionalized GNRs coupled with OCT to be adopted for longitudinal studies of retinal disorders.
Modelling the dependence of contrast sensitivity on grating area and spatial frequency.
Rovamo, J; Luntinen, O; Näsänen, R
1993-12-01
We modelled the human foveal visual system in a detection task as a simple image processor comprising (i) low-pass filtering due to the optical transfer function of the eye, (ii) high-pass filtering of neural origin, (iii) addition of internal neural noise, and (iv) detection by a local matched filter. Its detection efficiency for gratings was constant up to a critical area but then decreased with increasing area. To test the model we measured Michelson contrast sensitivity as a function of grating area at spatial frequencies of 0.125-32 c/deg for simple vertical and circular cosine gratings. In circular gratings luminance was sinusoidally modulated as a function of the radius of the grating field. In agreement with the model, contrast sensitivity at all spatial frequencies increased in proportion to the square-root of grating area at small areas. When grating area exceeded critical area, the increase saturated and contrast sensitivity became independent of area at large grating areas. Spatial integration thus obeyed Piper's law at small grating areas. The critical area of spatial integration, marking the cessation of Piper's law, was constant in solid degrees at low spatial frequencies but inversely proportional to spatial frequency squared at medium and high spatial frequencies. At low spatial frequencies the maximum contrast sensitivity obtainable by spatial integration increased in proportion to spatial frequency but at high spatial frequencies it decreased in proportion to the cube of the increasing spatial frequency. The increase was due to high-pass filtering of neural origin (lateral inhibition) and the decrease was mainly due to the optical transfer function of the eye. Our model explained 95% of the total variance of the contrast sensitivity data.
González Gómez, A; García-Ben, A; Soler García, A; García-Basterra, I; Padilla Parrado, F; García-Campos, J M
2017-03-15
The contrast sensitivity test determines the quality of visual function in patients with multiple sclerosis (MS). The purpose of this study is to analyse changes in visual function in patients with relapsing-remitting MS with and without a history of optic neuritis (ON). We conducted a longitudinal study including 61 patients classified into 3 groups as follows: a) disease-free patients (control group); b) patients with MS and no history of ON; and c) patients with MS and a history of unilateral ON. All patients underwent baseline and 6-year follow-up ophthalmologic examinations, which included visual acuity and monocular and binocular Pelli-Robson contrast sensitivity tests. Monocular contrast sensitivity was significantly lower in MS patients with and without a history of ON than in controls both at baseline (P=.00 and P=.01, respectively) and at 6 years (P=.01 and P=.02). Patients with MS and no history of ON remained stable throughout follow-up whereas those with a history of ON displayed a significant loss of contrast sensitivity (P=.01). Visual acuity and binocular contrast sensitivity at baseline and at 6 years was significantly lower in the group of patients with a history of ON than in the control group (P=.003 and P=.002 vs P=.006 and P=.005) and the group with no history of ON (P=.04 and P=.038 vs P=.008 and P=.01). However, no significant differences were found in follow-up results (P=.1 and P=.5). Monocular Pelli-Robson contrast sensitivity test may be used to detect changes in visual function in patients with ON. Copyright © 2017 The Author(s). Publicado por Elsevier España, S.L.U. All rights reserved.
Cabrerizo, Javier; Livny, Eitan; Musa, Fayyaz U; Leeuwenburgh, Paulien; van Dijk, Korine; Melles, Gerrit R J
2014-10-01
The aim of this study is to evaluate contrast sensitivity, color vision, and subjective patient satisfaction after Descemet membrane endothelial keratoplasty (DMEK) in patients with bilateral Fuchs endothelial dystrophy (FED). From a group of 500 DMEK surgeries performed in our center, patients with a history of bilateral FED and unilateral DMEK were identified. A total of 29 patients were included in the study and divided into 2 groups: phakic (n = 12) and pseudophakic unilateral DMEK (n = 17) and their contralateral, untreated FED-affected eye. In addition, a control group of 10 healthy eyes of 10 patients was included. Pelli-Robson contrast sensitivity and Farnsworth-Munsell 100 hue color vision tests were performed. Subjective optical quality was graded with a questionnaire. Compared with untreated FED-affected eyes, best spectacle-corrected visual acuity was higher after DMEK in phakic and pseudophakic eyes (P = 0.030 and P < 0.001, respectively); a similar result was obtained for contrast sensitivity (P < 0.001 and P < 0.001, respectively). Color vision did not differ between untreated FED-affected and DMEK-operated eyes in the phakic group (P = 0.802) and the pseudophakic group (P = 0.227). Subjective optical quality was better in DMEK-operated eyes than in untreated FED-affected eyes in the phakic group (P < 0.001) and in the pseudophakic group (P < 0.001). In FED, DMEK may not only be effective for obtaining a higher visual acuity but particularly improving the contrast sensitivity may also lead to better subjective optical performance. Although frequently mentioned spontaneously by patients, an objective change in color vision could not be substantiated. Hence, quantifying contrast sensitivity before surgery may aid in the decision for surgery, and in the evaluation of surgical outcome.
Evaluation of the Effects of Conjunctivochalasis Excision on Tear Stability and Contrast Sensitivity
Qiu, Weiqiang; Zhang, Mingzhou; Xu, Ting; Liu, Ziyuan; Lv, Huibin; Wang, Wei; Li, Xuemin
2016-01-01
Conjunctivochalasis (CCh) disrupts tear flow and damages tear film stability. This study sought to evaluate the tear stability and contrast sensitivity of patients with CCh on whom CCh excision was performed. The study included 39 eyes from 39 patients; all patients had eyes with grade 2 or 3 CCh, underwent CCh excision, and were evaluated before and three months after the surgery. The evaluated variables included the ocular surface disease index (OSDI), the tear break-up time (TBUT), corneal fluorescein staining, corneal surface irregularity, Schirmer’s I test, the tear meniscus area (TMA), and contrast sensitivity. A follow-up of three months was achieved in 36 eyes for 36 patients. All parameters improved significantly after surgery (p < 0.05), except Schirmer’s I test, thus suggesting that CCh excision is an effective method for reconstructing the lower tear meniscus and improving both tear film stability and corneal surface irregularity. The results further demonstrated a simultaneous increase in contrast sensitivity after surgery. PMID:27892479
Giacomelli, Giovanni; Virgili, Gianni; Giansanti, Fabrizio; Sato, Giovanni; Cappello, Ezio; Cruciani, Filippo; Varano, Monica; Menchini, Ugo
2013-06-27
To investigate the simultaneous association of several psychophysical measures with reading ability in patients with mild and moderate low vision attending rehabilitation services. Standard measurements of reading ability (Minnesota Reading [MNREAD] charts), visual acuity (Early Treatment of Diabetic Retinopathy Study [ETDRS] charts), contrast sensitivity (Pelli-Robson charts), reading contrast threshold (Reading Explorer [REX] charts), retinal sensitivity, and fixation stability and localization (Micro Perimeter 1 [MP1] fundus perimetry) were obtained in 160 low vision patients with better eye visual acuity ranging from 0.3 to 1.0 logarithm of the minimum angle of resolution and affected by either age-related macular degeneration or diabetic retinopathy. All variables were moderately associated with reading performance measures (MNREAD reading speed and reading acuity and REX reading contrast threshold), as well as among each other. In a structural equation model, REX reading contrast threshold was highly associated with MNREAD reading speed (standardized coefficient, 0.63) and moderately associated with reading acuity (standardized coefficient, -0.30). REX test also mediated the effects of Pelli-Robson contrast sensitivity (standardized coefficient, 0.44), MP1 fixation eccentricity (standardized coefficient, -0.19), and the mean retinal sensitivity (standardized coefficient, 0.23) on reading performance. The MP1 fixation stability was associated with both MNREAD reading acuity (standardized coefficient, -0.24) and MNREAD reading speed (standardized coefficient, 0.23), while ETDRS visual acuity only affected reading acuity (standardized coefficient, 0.44). Fixation instability and contrast sensitivity loss are key factors limiting reading performance of patients with mild or moderate low vision. REX charts directly assess the impact of text contrast on letter recognition and text navigation and may be a useful aid in reading rehabilitation.
Color, contrast sensitivity, and the cone mosaic.
Williams, D; Sekiguchi, N; Brainard, D
1993-01-01
This paper evaluates the role of various stages in the human visual system in the detection of spatial patterns. Contrast sensitivity measurements were made for interference fringe stimuli in three directions in color space with a psychophysical technique that avoided blurring by the eye's optics including chromatic aberration. These measurements were compared with the performance of an ideal observer that incorporated optical factors, such as photon catch in the cone mosaic, that influence the detection of interference fringes. The comparison of human and ideal observer performance showed that neural factors influence the shape as well as the height of the foveal contrast sensitivity function for all color directions, including those that involve luminance modulation. Furthermore, when optical factors are taken into account, the neural visual system has the same contrast sensitivity for isoluminant stimuli seen by the middle-wavelength-sensitive (M) and long-wavelength-sensitive (L) cones and isoluminant stimuli seen by the short-wavelength-sensitive (S) cones. Though the cone submosaics that feed these chromatic mechanisms have very different spatial properties, the later neural stages apparently have similar spatial properties. Finally, we review the evidence that cone sampling can produce aliasing distortion for gratings with spatial frequencies exceeding the resolution limit. Aliasing can be observed with gratings modulated in any of the three directions in color space we used. We discuss mechanisms that prevent aliasing in most ordinary viewing conditions. Images Fig. 1 Fig. 8 PMID:8234313
Synthesis and characterization of a smart contrast agent sensitive to calcium.
Dhingra, Kirti; Maier, Martin E; Beyerlein, Michael; Angelovski, Goran; Logothetis, Nikos K
2008-08-07
A novel first-generation Ca2+ sensitive contrast agent, Gd-DOPTRA has been synthesized and characterized. The agent shows approximately 100% relaxivity enhancement upon addition of Ca2+. The agent is selective and sensitive to Ca2+ also in the presence of Mg2+ and Zn2+. The relaxivity studies carried out in physiological fluids prove the prospects of the agent for in vivo measurements.
de Rivera, Christina; Boutet, Isabelle; Zicker, Steven C; Milgram, Norton W
2005-03-01
Tasks requiring visual discrimination are commonly used in assessment of canine cognitive function. However, little is known about canine visual processing, and virtually nothing is known about the effects of age on canine visual function. This study describes a novel behavioural method developed to assess one aspect of canine visual function, namely contrast sensitivity. Four age groups (young, middle aged, old, and senior) were studied. We also included a group of middle aged to old animals that had been maintained for at least 4 years on a specially formulated food containing a broad spectrum of antioxidants and mitochondrial cofactors. Performance of this group was compared with a group in the same age range maintained on a control diet. In the first phase, all animals were trained to discriminate between two high contrast shapes. In the second phase, contrast was progressively reduced by increasing the luminance of the shapes. Performance decreased as a function of age, but the differences did not achieve statistical significance, possibly because of a small sample size in the young group. All age groups were able to acquire the initial discrimination, although the two older age groups showed slower learning. Errors increased with decreasing contrast with the maximal number of errors for the 1% contrast shape. Also, all animals on the antioxidant diet learned the task and had significantly fewer errors at the high contrast compared with the animals on the control diet. The initial results suggest that contrast sensitivity deteriorates with age in the canine while form perception is largely unaffected by age.
Functional Nanoparticles for Magnetic Resonance Imaging
Mao, Xinpei; Xu, Jiadi; Cui, Honggang
2016-01-01
Nanoparticle-based magnetic resonance imaging (MRI) contrast agents have received much attention over the past decade. By virtue of a high payload of magnetic moieties, enhanced accumulation at disease sites, and a large surface area for additional modification with targeting ligands, nanoparticle-based contrast agents offer promising new platforms to further enhance the high resolution and sensitivity of MRI for various biomedical applications. T2* superparamagnetic iron oxide nanoparticles (SPIONs) first demonstrated superior improvement on MRI sensitivity. The prevailing SPION attracted growing interest in the development of refined nanoscale versions of MRI contrast agents. Afterwards, T1-based contrast agents were developed, and became the most studied subject in MRI due to the positive contrast they provide that avoids the susceptibility associated with MRI signal reduction. Recently, chemical exchange saturation transfer (CEST) contrast agents have emerged and rapidly gained popularity. The unique aspect of CEST contrast agents is that their contrast can be selectively turned “on” and “off” by radiofrequency (RF) saturation. Their performance can be further enhanced by incorporating a large number of exchangeable protons into well-defined nanostructure. Besides activatable CEST contrast agents, there is growing interest in developing nanoparticle-based activatable MRI contrast agents responsive to stimuli (pH, enzyme, etc.), which improves sensitivity and specificity. In this review, we summarize the recent development of various types of nanoparticle-based MRI contrast agents, and have focused our discussions on the key advantages of introducing nanoparticles in MRI. PMID:27040463
Phu, Jack; Kalloniatis, Michael; Khuu, Sieu K.
2018-01-01
Purpose Current clinical perimetric test paradigms present stimuli randomly to various locations across the visual field (VF), inherently introducing spatial uncertainty, which reduces contrast sensitivity. In the present study, we determined the extent to which spatial uncertainty affects contrast sensitivity in glaucoma patients by minimizing spatial uncertainty through attentional cueing. Methods Six patients with open-angle glaucoma and six healthy subjects underwent laboratory-based psychophysical testing to measure contrast sensitivity at preselected locations at two eccentricities (9.5° and 17.5°) with two stimulus sizes (Goldmann sizes III and V) under different cueing conditions: 1, 2, 4, or 8 points verbally cued. Method of Constant Stimuli and a single-interval forced-choice procedure were used to generate frequency of seeing (FOS) curves at locations with and without VF defects. Results At locations with VF defects, cueing minimizes spatial uncertainty and improves sensitivity under all conditions. The effect of cueing was maximal when one point was cued, and rapidly diminished when more points were cued (no change to baseline with 8 points cued). The slope of the FOS curve steepened with reduced spatial uncertainty. Locations with normal sensitivity in glaucomatous eyes had similar performance to that of healthy subjects. There was a systematic increase in uncertainty with the depth of VF loss. Conclusions Sensitivity measurements across the VF are negatively affected by spatial uncertainty, which increases with greater VF loss. Minimizing uncertainty can improve sensitivity at locations of deficit. Translational Relevance Current perimetric techniques introduce spatial uncertainty and may therefore underestimate sensitivity in regions of VF loss. PMID:29600116
Bencsik, Martin; Al-Rwaili, Amgad; Morris, Robert; Fairhurst, David J; Mundell, Victoria; Cave, Gareth; McKendry, Jonathan; Evans, Stephen
2013-11-01
The direct in-vivo measurement of fluid pressure cannot be achieved with MRI unless it is done with the contribution of a contrast agent. No such contrast agents are currently available commercially, whilst those demonstrated previously only produced qualitative results due to their broad size distribution. Our aim is to quantitate then model the MR sensitivity to the presence of quasi-monodisperse microbubble populations. Lipid stabilised microbubble populations with mean radius 1.2 ± 0.8 μm have been produced by mechanical agitation. Contrast agents with increasing volume fraction of bubbles up to 4% were formed and the contribution the bubbles bring to the relaxation rate was quantitated. A periodic pressure change was also continuously applied to the same contrast agent, until MR signal changes were only due to bubble radius change and not due to a change in bubble density. The MR data compared favourably with the prediction of an improved numerical simulation. An excellent MR sensitivity of 23 % bar(-1) has been demonstrated. This work opens up the possibility of generating microbubble preparations tailored to specific applications with optimised MR sensitivity, in particular MRI based in-vivo manometry. Copyright © 2012 Wiley Periodicals, Inc.
Modification of YAPE keypoint detection algorithm for wide local contrast range images
NASA Astrophysics Data System (ADS)
Lukoyanov, A.; Nikolaev, D.; Konovalenko, I.
2018-04-01
Keypoint detection is an important tool of image analysis, and among many contemporary keypoint detection algorithms YAPE is known for its computational performance, allowing its use in mobile and embedded systems. One of its shortcomings is high sensitivity to local contrast which leads to high detection density in high-contrast areas while missing detections in low-contrast ones. In this work we study the contrast sensitivity of YAPE and propose a modification which compensates for this property on images with wide local contrast range (Yet Another Contrast-Invariant Point Extractor, YACIPE). As a model example, we considered the traffic sign recognition problem, where some signs are well-lighted, whereas others are in shadows and thus have low contrast. We show that the number of traffic signs on the image of which has not been detected any keypoints is 40% less for the proposed modification compared to the original algorithm.
Acosta-Rojas, E Ruthy; Comas, Mercè; Sala, Maria; Castells, Xavier
2006-10-01
To evaluate the association between visual impairment (visual acuity, contrast sensitivity, stereopsis) and patient-reported visual disability at different stages of cataract surgery. A cohort of 104 patients aged 60 years and over with bilateral cataract was assessed preoperatively, after first-eye surgery (monocular pseudophakia) and after second-eye surgery (binocular pseudophakia). Partial correlation coefficients (PCC) and linear regression models were calculated. In patients with bilateral cataracts, visual disability was associated with visual acuity (PCC = -0.30) and, to a lesser extent, with contrast sensitivity (PCC = 0.16) and stereopsis (PCC = -0.09). In monocular and binocular pseudophakia, visual disability was more strongly associated with stereopsis (PCC = -0.26 monocular and -0.51 binocular) and contrast sensitivity (PCC = 0.18 monocular and 0.34 binocular) than with visual acuity (PCC = -0.18 monocular and -0.18 binocular). Visual acuity, contrast sensitivity and stereopsis accounted for between 17% and 42% of variance in visual disability. The association of visual impairment with patient-reported visual disability differed at each stage of cataract surgery. Measuring other forms of visual impairment independently from visual acuity, such as contrast sensitivity or stereopsis, could be important in evaluating both needs and outcomes in cataract surgery. More comprehensive assessment of the impact of cataract on patients should include measurement of both visual impairment and visual disability.
Interactions between chromatic- and luminance-contrast-sensitive stereopsis mechanisms.
Simmons, David R; Kingdom, Frederick A A
2002-06-01
It is well known that chromatic information can assist in solving the stereo correspondence problem. It has also been suggested that there are two independent first-order stereopsis mechanisms, one sensitive to chromatic contrast and the other sensitive to luminance contrast (Vision Research 37 (1997) 1271). Could the effect of chromatic information on stereo correspondence be subserved by interactions between these mechanisms? To address this question, disparity thresholds (1/stereoacuity) were measured using 0.5 cpd Gabor patches. The stimuli possessed different relative amounts of chromatic and luminance contrast which could be correlated or anti-correlated between the eyes. Stereoscopic performance with these compound stimuli was compared to that with purely isoluminant and isochromatic stimuli at different contrasts. It was found that anti-correlated chromatic contrast severely disrupted stereopsis with achromatic stimuli and that anti-correlated luminance contrast severely disrupted stereopsis with chromatic stimuli. Less dramatic, but still significant, was the improvement in stereoacuity obtained using correlated colour and luminance contrast. These data are consistent with there being positive and negative interactions between chromatic and achromatic stereopsis mechanisms that take place after the initial encoding of disparity information, but before the extraction of stereoscopic depth. These interactions can be modelled satisfactorily assuming probability summation of depth sign information between independent mechanisms.
Rasper, Michael; Wildgruber, Moritz; Settles, Marcus; Eckstein, Hans-Henning; Zimmermann, Alexander; Reeps, Christian; Rummeny, Ernst J; Huber, Armin M
2016-09-01
To compare prospectively image quality and diagnostic confidence of flow-sensitive 3D turbo spin echo (TSE)-based non-contrast-enhanced MR angiography (NE-MRA) at 3.0 T using dual-source radiofrequency (RF) transmission with contrast-enhanced MRA (CE-MRA) in patients with peripheral arterial occlusive disease (PAOD). After consent was obtained, 35 patients (mean age 69.1 ± 10.6 years) with PAOD stage II-IV underwent NE-MRA followed by CE-MRA. Signal-to-noise ratio and contrast-to-noise ratio were calculated. Subjective image quality was independently assessed by two radiologists and stenosis scoring was performed in 875 arterial segments. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for stenosis classification were calculated using CE-MRA as a reference method. Diagnostic agreement with CE-MRA was evaluated with Cohen's kappa statistics. NE-MRA provided high objective and subjective image quality at all levels of the arterial tree. Sensitivity and specificity for the detection of relevant stenosis was 91 % and 89 %, respectively; the NPV was 96 % and the PPV 78 %. There was good concordance between CE-MRA and NE-MRA in stenosis scoring. 3D electrocardiography (ECG)-gated TSE NE-MRA with patient-adaptive dual-source RF transmission at 3.0 T is a promising alternative for PAOD patients with contraindications for gadolinium-based contrast agents. It offers high sensitivity and NPV values in the detection of clinically relevant arterial stenosis. • Flow-sensitive TSE NE-MRA is a promising technique for PAOD evaluation. • Diagnostic accuracy is comparable to contrast-enhanced MRA. • NE-MRA eliminates the risk of NSF in patients with renal insufficiency. • Costs arising from the use of contrast agents can be avoided.
Semileptonic decays of B and D mesons in the light-front formalism
NASA Astrophysics Data System (ADS)
Jaus, W.
1990-06-01
The light-front formalism is used to present a relativistic calculation of form factors for semileptonic D and B decays in the constituent quark model. The quark-antiquark wave functions of the mesons can be obtained, in principle, from an analysis of the meson spectrum, but are approximated in this work by harmonic-oscillator wave functions. The predictions of the model are consistent with the experimental data for B decays. The Kobayashi-Maskawa (KM) matrix element ||Vcs|| is determined by a comparison of the experimental and theoretical rates for D0-->K-e+ν, and is consistent with a unitary KM matrix for three families. The predictions for D-->K* transitions are in conflict with the data.
Study of the Decays D0→π-e+νe, D0→K-e+νe, D+→π0e+νe, and D+→ Kmacr 0e+νe
NASA Astrophysics Data System (ADS)
Cronin-Hennessy, D.; Gao, K. Y.; Gong, D. T.; Hietala, J.; Kubota, Y.; Klein, T.; Lang, B. W.; Poling, R.; Scott, A. W.; Smith, A.; Zweber, P.; Dobbs, S.; Metreveli, Z.; Seth, K. K.; Tomaradze, A.; Ernst, J.; Severini, H.; Dytman, S. A.; Love, W.; Savinov, V.; Aquines, O.; Li, Z.; Lopez, A.; Mehrabyan, S.; Mendez, H.; Ramirez, J.; Huang, G. S.; Miller, D. H.; Pavlunin, V.; Sanghi, B.; Shipsey, I. P. J.; Xin, B.; Adams, G. S.; Anderson, M.; Cummings, J. P.; Danko, I.; Napolitano, J.; He, Q.; Insler, J.; Muramatsu, H.; Park, C. S.; Thorndike, E. H.; Yang, F.; Coan, T. E.; Gao, Y. S.; Liu, F.; Artuso, M.; Blusk, S.; Butt, J.; Li, J.; Menaa, N.; Mountain, R.; Nisar, S.; Randrianarivony, K.; Redjimi, R.; Sia, R.; Skwarnicki, T.; Stone, S.; Wang, J. C.; Zhang, K.; Csorna, S. E.; Bonvicini, G.; Cinabro, D.; Dubrovin, M.; Lincoln, A.; Asner, D. M.; Edwards, K. W.; Briere, R. A.; Brock, I.; Chen, J.; Ferguson, T.; Tatishvili, G.; Vogel, H.; Watkins, M. E.; Rosner, J. L.; Adam, N. E.; Alexander, J. P.; Berkelman, K.; Cassel, D. G.; Duboscq, J. E.; Ecklund, K. M.; Ehrlich, R.; Fields, L.; Gibbons, L.; Gray, R.; Gray, S. W.; Hartill, D. L.; Heltsley, B. K.; Hertz, D.; Jones, C. D.; Kandaswamy, J.; Kreinick, D. L.; Kuznetsov, V. E.; Mahlke-Krüger, H.; Onyisi, P. U. E.; Patterson, J. R.; Peterson, D.; Pivarski, J.; Riley, D.; Ryd, A.; Sadoff, A. J.; Schwarthoff, H.; Shi, X.; Stroiney, S.; Sun, W. M.; Wilksen, T.; Weinberger, M.; Athar, S. B.; Patel, R.; Potlia, V.; Yelton, J.; Rubin, P.; Cawlfield, C.; Eisenstein, B. I.; Karliner, I.; Kim, D.; Lowrey, N.; Naik, P.; Sedlack, C.; Selen, M.; White, E. J.; Wiss, J.; Shepherd, M. R.; Besson, D.; Pedlar, T. K.
2008-06-01
By using 1.8×106 D Dmacr pairs, we have measured B(D0→π-e+νe)=0.299(11)(9)%, B(D+→π0e+νe)=0.373(22)(13)%, B(D0→K-e+νe)=3.56(3)(9)%, and B(D+→ Kmacr 0e+νe)=8.53(13)(23)% and have studied the q2 dependence of the form factors. By combining our results with recent lattice calculations, we obtain |Vcd|=0.217(9)(4)(23) and |Vcs|=1.015(10)(11)(106).
D → Klv semileptonic decay using lattice QCD with HISQ at physical pion masses
NASA Astrophysics Data System (ADS)
Chakraborty, Bipasha; Davies, Christine; Koponen, Jonna; Lepage, G. Peter
2018-03-01
he quark flavor sector of the Standard Model is a fertile ground to look for new physics effects through a unitarity test of the Cabbibo-Kobayashi-Maskawa (CKM) matrix. We present a lattice QCD calculation of the scalar and the vector form factors (over a large q2 region including q2 = 0) associated with the D→ Klv semi-leptonic decay. This calculation will then allow us to determine the central CKM matrix element, Vcs in the Standard Model, by comparing the lattice QCD results for the form factors and the experimental decay rate. This form factor calculation has been performed on the Nf = 2 + 1 + 1 MILC HISQ ensembles with the physical light quark masses.
Fostering a new dialogue to improve access to finance for European biopharma SMEs.
Chantelot, Emmanuel; Suojanen, Christian
2010-12-31
This article reviews the current economic crisis as it impacts upon European biopharma SMEs and their ability to secure investment and funding. In particular it presents an analysis of a broader, pre-crisis structural problem in Europe related to the lack of institutional investors for Europe's life sciences venture capital funds and the impact this has both on the funds available for investment by VCs into Europe's biotech companies, and the effect on the type and stage of biopharma companies able to raise money. This article also presents an overview of an on-going stakeholder dialogue to address these issues and the proposals raised so far for possible solutions. Copyright © 2010 Elsevier B.V. All rights reserved.
Venture Capital Investment in the Life Sciences in Switzerland.
Hosang, Markus
2014-12-01
Innovation is one of the main driving factors for continuous and healthy economic growth and welfare. Switzerland as a resource-poor country is particularly dependent on innovation, and the life sciences, which comprise biotechnologies, (bio)pharmaceuticals, medical technologies and diagnostics, are one of the key areas of innovative strength of Switzerland. Venture capital financing and venture capitalists (frequently called 'VCs') and investors in public equities have played and still play a pivotal role in financing the Swiss biotechnology industry. In the following some general features of venture capital investment in life sciences as well as some opportunities and challenges which venture capital investors in Switzerland are facing are highlighted. In addition certain means to counteract these challenges including the 'Zukunftsfonds Schweiz' are discussed.
Brightness discrimination and contrast sensitivity in chronic glaucoma--a clinical study.
Teoh, S L; Allan, D; Dutton, G N; Foulds, W S
1990-01-01
The visual acuity, the difference in sensitivity of the two eyes to light (brightness ratio), and contrast sensitivity were assessed in 28 patients with chronic open angle glaucoma and compared with those of 41 normal controls of similar ages and visual acuity. The results obtained were related to the results of Tübingen visual field analysis in patients with glaucoma. Twenty-four of the 28 glaucoma patients (86%) had a significant disparity in brightness ratio between the two eyes. This was found to match the frequency of visual field loss. Moreover, there was a significant relationship between the interocular differences in brightness sense and the difference in the degree of visual field loss between the two eyes. Of the glaucoma patients 39% had sum contrast sensitivities outside the normal range for age-matched normal controls. No significant correlation was found between the interocular difference in brightness sense and the visual acuity or the interocular difference in sum contrast sensitivity. It is concluded that, in the presence of a normal visual acuity, the brightness ratio test warrants evaluation as a potential screening test for chronic open angle glaucoma. PMID:2186795
Thurman, Steven M.; Davey, Pinakin Gunvant; McCray, Kaydee Lynn; Paronian, Violeta; Seitz, Aaron R.
2016-01-01
Contrast sensitivity (CS) is widely used as a measure of visual function in both basic research and clinical evaluation. There is conflicting evidence on the extent to which measuring the full contrast sensitivity function (CSF) offers more functionally relevant information than a single measurement from an optotype CS test, such as the Pelli–Robson chart. Here we examine the relationship between functional CSF parameters and other measures of visual function, and establish a framework for predicting individual CSFs with effectively a zero-parameter model that shifts a standard-shaped template CSF horizontally and vertically according to independent measurements of high contrast acuity and letter CS, respectively. This method was evaluated for three different CSF tests: a chart test (CSV-1000), a computerized sine-wave test (M&S Sine Test), and a recently developed adaptive test (quick CSF). Subjects were 43 individuals with healthy vision or impairment too mild to be considered low vision (acuity range of −0.3 to 0.34 logMAR). While each test demands a slightly different normative template, results show that individual subject CSFs can be predicted with roughly the same precision as test–retest repeatability, confirming that individuals predominantly differ in terms of peak CS and peak spatial frequency. In fact, these parameters were sufficiently related to empirical measurements of acuity and letter CS to permit accurate estimation of the entire CSF of any individual with a deterministic model (zero free parameters). These results demonstrate that in many cases, measuring the full CSF may provide little additional information beyond letter acuity and contrast sensitivity. PMID:28006065
Ganglion Cell Loss and Age-Related Visual Loss: A Cortical Pooling Analysis
SCHMIDT, LAURA A.; LY-SCHROEDER, EMILY; SWANSON, WILLIAM H.
2006-01-01
Purpose To evaluate the ability of the cortical pooling model to predict the effects of random, mild ganglion cell loss, we compared the predictions of the model with the age-related loss and variability in achromatic and chromatic contrast sensitivity. Methods The relative sensitivity to small (0.5°) and large (3.0°) stimuli was compared in older (mean = 67 years, n = 27) and younger (mean = 23 years, n = 32) adults. Contrast sensitivity for modulations along the luminance, equiluminant L-cone, and equiluminant S-cone axes was assessed at the fovea and at four peripheral locations (12°). Results When the stimuli were large, threshold measurements obtained from all participants were reliable and well within the range of modulations along the chromatic axes that could be produced by the phosphors of the CRT. For the large stimuli, neither long- nor short-term variability increased as a function of age. Increasing the size of the stimulus did not decrease the magnitude of the age-related losses when the stimulus was chromatic, and visual losses observed with large chromatic stimuli were not different from those obtained with small achromatic stimuli. Moreover, chromatic contrast sensitivity assessments identified significant visual losses in four individuals who were not identified by achromatic contrast sensitivity assessments and only missed identifying one individual with significant losses in achromatic contrast sensitivity. Conclusions The declines in achromatic and chromatic sensitivity as a function of age (0.4 – 0.7 dB per decade) were similar to those obtained in previous studies of achromatic and chromatic perimetry and are consistent with the loss of retinal ganglion cells reported in histologic studies. The results of this study are consistent with the predictions the cortical pooling model makes for both variability and contrast sensitivity. These findings emphasize that selective visual impairments do not necessarily reflect preferential damage to a single ganglion cell class and that it is important to include the influence of higher cortical processing when quantifying the relation between ganglion cells and visual function. PMID:16840870
Effect of text type on near work-induced contrast adaptation in myopic and emmetropic young adults.
Yeo, Anna C H; Atchison, David A; Schmid, Katrina L
2013-02-27
Contrast adaptation has been speculated to be an error signal for emmetropization. Myopic children exhibit higher contrast adaptation than emmetropic children. This study aimed to determine whether contrast adaptation varies with the type of text viewed by emmetropic and myopic young adults. Baseline contrast sensitivity was determined in 25 emmetropic and 25 spectacle-corrected myopic young adults for 0.5, 1.2, 2.7, 4.4, and 6.2 cycles per degree (cpd) horizontal sine wave gratings. The adults spent periods looking at a 6.2 cpd high-contrast horizontal grating and reading lines of English and Chinese text (these texts comprised 1.2 cpd row and 6 cpd stroke frequencies). The effects of these near tasks on contrast sensitivity were determined, with decreases in sensitivity indicating contrast adaptation. Contrast adaptation was affected by the near task (F2,672 = 43.0; P < 0.001). Adaptation was greater for the grating task (0.13 ± 0.17 log unit, averaged across all frequencies) than reading tasks, but there was no significant difference between the two reading tasks (English 0.05 ± 0.13 log unit versus Chinese 0.04 ± 0.13 log unit). The myopic group showed significantly greater adaptation (by 0.04, 0.04, and 0.05 log units for English, Chinese, and grating tasks, respectively) than the emmetropic group (F1,48 = 5.0; P = 0.03). In young adults, reading Chinese text induced similar contrast adaptation as reading English text. Myopes exhibited greater contrast adaptation than emmetropes. Contrast adaptation, independent of text type, might be associated with myopia development.
High resolution laboratory grating-based x-ray phase-contrast CT
NASA Astrophysics Data System (ADS)
Viermetz, Manuel P.; Birnbacher, Lorenz J. B.; Fehringer, Andreas; Willner, Marian; Noel, Peter B.; Pfeiffer, Franz; Herzen, Julia
2017-03-01
Grating-based phase-contrast computed tomography (gbPC-CT) is a promising imaging method for imaging of soft tissue contrast without the need of any contrast agent. The focus of this study is the increase in spatial resolution without loss in sensitivity to allow visualization of pathologies comparable to the convincing results obtained at the synchrotron. To improve the effective pixel size a super-resolution reconstruction based on subpixel shifts involving a deconvolution of the image is applied on differential phase-contrast data. In our study we could achieve an effective pixel sizes of 28mm without any drawback in terms of sensitivity or the ability to measure quantitative data.
A System for Controlled Presentation of the Arden Contrast Sensitivity Test.
1985-12-01
and Woo,1978); I.?glaucoma (Atkin, et al,1979); amblyopia (Hess,1979); retinal degeneration (Woo and Long,1979); multiple sclerosis (Regan, et al...decrease, contrast sensitivity diminishes, and imaging L shifts to an area covering 12 -15 of the peripheral macula . The theoretical threshold grid
Geometrically confined ultrasmall gadolinium oxide nanoparticles boost the T1 contrast ability
NASA Astrophysics Data System (ADS)
Ni, Kaiyuan; Zhao, Zhenghuan; Zhang, Zongjun; Zhou, Zijian; Yang, Li; Wang, Lirong; Ai, Hua; Gao, Jinhao
2016-02-01
High-performance magnetic resonance imaging (MRI) contrast agents and novel contrast enhancement strategies are urgently needed for sensitive and accurate diagnosis. Here we report a strategy to construct a new T1 contrast agent based on the Solomon-Bloembergen-Morgan (SBM) theory. We loaded the ultrasmall gadolinium oxide nanoparticles into worm-like interior channels of mesoporous silica nanospheres (Gd2O3@MSN nanocomposites). This unique structure endows the nanocomposites with geometrical confinement, high molecular tumbling time, and a large coordinated number of water molecules, which results in a significant enhancement of the T1 contrast with longitudinal proton relaxivity (r1) as high as 45.08 mM-1 s-1. Such a high r1 value of Gd2O3@MSN, compared to those of ultrasmall Gd2O3 nanoparticles and gadolinium-based clinical contrast agents, is mainly attributed to the strong geometrical confinement effect. This strategy provides new guidance for developing various high-performance T1 contrast agents for sensitive imaging and disease diagnosis.High-performance magnetic resonance imaging (MRI) contrast agents and novel contrast enhancement strategies are urgently needed for sensitive and accurate diagnosis. Here we report a strategy to construct a new T1 contrast agent based on the Solomon-Bloembergen-Morgan (SBM) theory. We loaded the ultrasmall gadolinium oxide nanoparticles into worm-like interior channels of mesoporous silica nanospheres (Gd2O3@MSN nanocomposites). This unique structure endows the nanocomposites with geometrical confinement, high molecular tumbling time, and a large coordinated number of water molecules, which results in a significant enhancement of the T1 contrast with longitudinal proton relaxivity (r1) as high as 45.08 mM-1 s-1. Such a high r1 value of Gd2O3@MSN, compared to those of ultrasmall Gd2O3 nanoparticles and gadolinium-based clinical contrast agents, is mainly attributed to the strong geometrical confinement effect. This strategy provides new guidance for developing various high-performance T1 contrast agents for sensitive imaging and disease diagnosis. Electronic supplementary information (ESI) available: Supplementary Fig. S1-S6. See DOI: 10.1039/c5nr08402d
Processing Deficits of Motion of Contrast-Modulated Gratings in Anisometropic Amblyopia
Liu, Zhongjian; Hu, Xiaopeng; Yu, Yong-Qiang; Zhou, Yifeng
2014-01-01
Several studies have indicated substantial processing deficits for static second-order stimuli in amblyopia. However, less is known about the perception of second-order moving gratings. To investigate this issue, we measured the contrast sensitivity for second-order (contrast-modulated) moving gratings in seven anisometropic amblyopes and ten normal controls. The measurements were performed with non-equated carriers and a series of equated carriers. For comparison, the sensitivity for first-order motion and static second-order stimuli was also measured. Most of the amblyopic eyes (AEs) showed reduced sensitivity for second-order moving gratings relative to their non-amblyopic eyes (NAEs) and the dominant eyes (CEs) of normal control subjects, even when the detectability of the noise carriers was carefully controlled, suggesting substantial processing deficits of motion of contrast-modulated gratings in anisometropic amblyopia. In contrast, the non-amblyopic eyes of the anisometropic amblyopes were relatively spared. As a group, NAEs showed statistically comparable performance to CEs. We also found that contrast sensitivity for static second-order stimuli was strongly impaired in AEs and part of the NAEs of anisometropic amblyopes, consistent with previous studies. In addition, some amblyopes showed impaired performance in perception of static second-order stimuli but not in that of second-order moving gratings. These results may suggest a dissociation between the processing of static and moving second-order gratings in anisometropic amblyopia. PMID:25409477
Hayashi, Ken; Hayashi, Hideyuki
2004-08-01
To compare the impairment in visual function caused by glare with 2 acrylic intraocular lenses (IOLs) with different modified optic edges. Hayashi Eye Hospital, Fukuoka, Japan. Fifty-four patients had implantation of an IOL with a textured edge (Alcon MA60AC) in 1 eye and an IOL with a round-anterior, sloped-sided edge (AMO AR40e) in the opposite eye. Visual acuity was measured at 5 contrast visual targets (100%, 25%, 10%, 5%, and 2.5%) (contrast visual acuity) under photopic and mesopic conditions with and without a glare source approximately 1 month after surgery using the Contrast Sensitivity Accurate Tester (Menicon CAT-2000). The mean mesopic contrast visual acuity at moderate- to low-contrast visual targets was significantly worse in the presence of a glare source in both groups, whereas photopic contrast visual acuity did not change significantly. There were no significant differences between the 2 groups in the mean visual acuity or in photopic or mesopic lighting contrast visual acuity with and without a glare source. Furthermore, there was no significant difference in loss of contrast visual acuity in the presence of glare. Mesopic contrast sensitivity with both acrylic IOLs was impaired significantly in the presence of glare, but the impairment of contrast sensitivity from glare was approximately the same between eyes with a textured-edge IOL and eyes with a round-anterior, sloped-sided edge IOL.
Rapid quantification of color vision: the cone contrast test.
Rabin, Jeff; Gooch, John; Ivan, Douglas
2011-02-09
To describe the design, specificity, and sensitivity of the cone contrast test (CCT), a computer-based, cone-specific (L, M, S) contrast sensitivity test for diagnosing type and severity of color vision deficiency (CVD). The CCT presents a randomized series of colored letters visible only to L, M or S cones in decreasing steps of cone contrast to determine L, M, and S letter-recognition thresholds. Sensitivity and specificity were determined by retrospective comparison of CCT scores to anomaloscope and pseudoisochromatic plate (PIP) results in 1446 applicants for pilot training. CVD was detected in 49 (3.4%) of 1446 applicants with hereditary red-green (protan or deutan) CVD detected in 47 (3.5%) of 1359 men and blue-yellow (tritan) in 2 of 1446. In agreement with the anomaloscope, the CCT showed 100% sensitivity for detection and categorization of CVD (40 deutan, 7 protan, 2 tritan). PIP testing showed lower sensitivity (80% detected; 20% missed) due in part to the applicant's prior experience and/or pretest preparation. CCT specificity for confirming normal color vision was 100% for L and M cone tests and 99.8% for S cones. The CCT has sensitivity and specificity comparable to anomaloscope testing and exceeds PIP sensitivity in practiced observers. The CCT provides a rapid (6 minutes), clinically expedient, measure of color vision for quantifying normal color performance, diagnosing type and severity of hereditary deficiency, and detection of acquired sensitivity loss due to ocular, neurologic, and/or systemic disease, as well as injury and physiological stressors, such as altitude and fatigue.
Lantos, Joshua E; Levine, Marc S; Rubesin, Stephen E; Lau, Charles T; Torigian, Drew A
2013-03-01
To assess the diagnostic performance of esophagography and chest computed tomography (CT) for detecting leaks after esophagectomy and gastric pull-through. Our database revealed 29 patients who had undergone esophagography and chest CT after esophagectomy. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for postoperative leaks were determined for esophagography and CT, separately and combined, on the basis of a retrospective image review. Patients were also stratified for esophagograms with water-soluble contrast alone versus water-soluble contrast and high-density barium and for CT with and without oral contrast. Our findings were retrospectively compared with those reported at initial image interpretation. Clinically relevant leaks were present in 14 (48%) of 29 patients after esophagectomy. Esophagography had a sensitivity of 79%, specificity of 73%, PPV of 73%, and NPV of 79% for detecting leaks, whereas CT had a sensitivity of 86%, specificity of 33%, PPV of 55%, and NPV of 71% and esophagography and CT combined had a sensitivity of 100%, specificity of 27%, PPV of 56%, and NPV of 100%. The sensitivity of esophagography increased with high-density barium, whereas the sensitivity of CT was the same with and without oral contrast agent. Finally, esophagography and CT were seen to have a higher sensitivity and lower specificity on retrospective review compared with the results reported at initial image interpretation. Esophagography had a slightly lower sensitivity and substantially higher specificity compared with CT for detecting leaks after esophagectomy, whereas esophagography and CT combined had a sensitivity of 100% for detecting leaks. Therefore, postoperative leaks can be excluded with confidence after esophagectomy when both tests are negative.
ERIC Educational Resources Information Center
Geri, George A.; Hubbard, David C.
Two adaptive psychophysical procedures (tracking and "yes-no" staircase) for obtaining human visual contrast sensitivity functions (CSF) were evaluated. The procedures were chosen based on their proven validity and the desire to evaluate the practical effects of stimulus transients, since tracking procedures traditionally employ gradual…
NASA Astrophysics Data System (ADS)
Walther, Julia; Golde, Jonas; Kirsten, Lars; Tetschke, Florian; Hempel, Franz; Rosenauer, Tobias; Hannig, Christian; Koch, Edmund
2017-12-01
Since optical coherence tomography (OCT) provides three-dimensional high-resolution images of biological tissue, the benefit of polarization contrast in the field of dentistry is highlighted in this study. Polarization-sensitive OCT (PS OCT) with phase-sensitive recording is used for imaging dental and mucosal tissues in the human oral cavity in vivo. An enhanced polarization contrast of oral structures is reached by analyzing the signals of the co- and crosspolarized channels of the swept source PS OCT system quantitatively with respect to reflectivity, retardation, optic axis orientation, and depolarization. The calculation of these polarization parameters enables a high tissue-specific contrast imaging for the detailed physical interpretation of human oral hard and soft tissues. For the proof-of-principle, imaging of composite restorations and mineralization defects at premolars as well as gingival, lingual, and labial oral mucosa was performed in vivo within the anterior oral cavity. The achieved contrast-enhanced results of the investigated human oral tissues by means of polarization-sensitive imaging are evaluated by the comparison with conventional intensity-based OCT.
Canuto, Holly C; McLachlan, Charles; Kettunen, Mikko I; Velic, Marko; Krishnan, Anant S; Neves, Andre' A; de Backer, Maaike; Hu, D-E; Hobson, Michael P; Brindle, Kevin M
2009-05-01
A targeted Gd(3+)-based contrast agent has been developed that detects tumor cell death by binding to the phosphatidylserine (PS) exposed on the plasma membrane of dying cells. Although this agent has been used to detect tumor cell death in vivo, the differences in signal intensity between treated and untreated tumors was relatively small. As cell death is often spatially heterogeneous within tumors, we investigated whether an image analysis technique that parameterizes heterogeneity could be used to increase the sensitivity of detection of this targeted contrast agent. Two-dimensional (2D) Minkowski functionals (MFs) provided an automated and reliable method for parameterization of image heterogeneity, which does not require prior assumptions about the number of regions or features in the image, and were shown to increase the sensitivity of detection of the contrast agent as compared to simple signal intensity analysis. (c) 2009 Wiley-Liss, Inc.
Oxygenation state and twilight vision at 2438 m.
Connolly, Desmond M
2011-01-01
Under twilight viewing conditions, hypoxia, equivalent to breathing air at 3048 m (10,000 ft), compromises low contrast acuity, dynamic contrast sensitivity, and chromatic sensitivity. Selected past experiments have been repeated under milder hypoxia, equivalent to altitude exposure below 2438 m (8000 ft), to further define the influence of oxygenation state on mesopic vision. To assess photopic and mesopic visual function, 12 subjects each undertook three experiments using the Contrast Acuity Assessment test, the Frequency Doubling Perimeter, and the Color Assessment and Diagnosis (CAD) test. Experiments were conducted near sea level breathing 15.2% oxygen (balance nitrogen) and 100% oxygen, representing mild hypobaric hypoxia at 2438 m (8000 ft) and the benefit of supplementary oxygen, respectively. Oxygenation state was a statistically significant determinant of visual performance on all three visual parameters at mesopic, but not photopic, luminance. Mesopic sensitivity was greater with supplementary oxygen, but the magnitude of each hypoxic decrement was slight. Hypoxia elevated mesopic contrast acuity thresholds by approximately 4%; decreased mesopic dynamic contrast sensitivity by approximately 2 dB; and extended mean color ellipse axis length by approximately one CAD unit at mesopic luminance (that is, hypoxia decreased chromatic sensitivity). The results indicate that twilight vision may be susceptible to conditions of altered oxygenation at upper-to-mid mesopic luminance with relevance to contemporary night flying, including using night vision devices. Supplementary oxygen should be considered when optimal visual performance is mission-critical during flight above 2438 m (8000 ft) in dim light.
Zhao, Enfa; Cheng, Gesheng; Wang, Yingli
2017-01-01
The aim of this study is to evaluate the ability of two different contrast agents to detect cardiac right-to-left shunting in patients with a patent foramen ovale during contrast transthoracic echocardiography and transesophageal echocardiography. Eighty-four patients who had migraines or experienced cryptogenic stroke were prospectively enrolled. Contrast echocardiography of the right portion of the heart was performed using an injection of either (i) 8 ml of agitated saline, 1 ml of blood, and 1 ml of air (ASB) or (ii) 4 ml of vitamin B6 and 6 ml of sodium bicarbonate solution (VSBS). All patients underwent contrast echocardiography with different contrast agents successively before undergoing transesophageal echocardiography. The diagnostic sensitivity of VSBS and ASB for cardiac shunting diagnosis was 94.23% and 78.85%, respectively. The diagnostic sensitivity in the VSBS group was significantly higher than that in the ASB group (χ2 = 5.283, P = 0.022). The observed semiquantitative shunt grading suggests that the positive rate in the VSBS group was higher than that in the ASB group (Z = −1.998, P = 0.046). The use of vitamin B6 and sodium bicarbonate solution as a TTE contrast agent yielded a high sensitivity compared with ASB. However, further trials with large sample size are required to confirm this finding. PMID:29333447
Training in Contrast Detection Improves Motion Perception of Sinewave Gratings in Amblyopia
Hou, Fang; Huang, Chang-bing; Tao, Liming; Feng, Lixia; Zhou, Yifeng; Lu, Zhong-Lin
2011-01-01
Purpose. One critical concern about using perceptual learning to treat amblyopia is whether training with one particular stimulus and task generalizes to other stimuli and tasks. In the spatial domain, it has been found that the bandwidth of contrast sensitivity improvement is much broader in amblyopes than in normals. Because previous studies suggested the local motion deficits in amblyopia are explained by the spatial vision deficits, the hypothesis for this study was that training in the spatial domain could benefit motion perception of sinewave gratings. Methods. Nine adult amblyopes (mean age, 22.1 ± 5.6 years) were trained in a contrast detection task in the amblyopic eye for 10 days. Visual acuity, spatial contrast sensitivity functions, and temporal modulation transfer functions (MTF) for sinewave motion detection and discrimination were measured for each eye before and after training. Eight adult amblyopes (mean age, 22.6 ± 6.7 years) served as control subjects. Results. In the amblyopic eye, training improved (1) contrast sensitivity by 6.6 dB (or 113.8%) across spatial frequencies, with a bandwidth of 4.4 octaves; (2) sensitivity of motion detection and discrimination by 3.2 dB (or 44.5%) and 3.7 dB (or 53.1%) across temporal frequencies, with bandwidths of 3.9 and 3.1 octaves, respectively; (3) visual acuity by 3.2 dB (or 44.5%). The fellow eye also showed a small amount of improvement in contrast sensitivities and no significant change in motion perception. Control subjects who received no training demonstrated no obvious improvement in any measure. Conclusions. The results demonstrate substantial plasticity in the amblyopic visual system, and provide additional empirical support for perceptual learning as a potential treatment for amblyopia. PMID:21693615
Barreto, Jackson; Barboni, Mirella T S; Feitosa-Santana, Claudia; Sato, João R; Bechara, Samir J; Ventura, Dora F; Alves, Milton Ruiz
2010-08-01
To compare intraocular straylight measurements and contrast sensitivity after wavefront-guided LASIK (WFG LASIK) in one eye and wavefront-guided photorefractive keratectomy (WFG PRK) in the fellow eye for myopia and myopic astigmatism correction. A prospective, randomized study of 22 eyes of 11 patients who underwent simultaneous WFG LASIK and WFG PRK (contralateral eye). Both groups were treated with the NIDEK Advanced Vision Excimer Laser System, and a microkeratome was used for flap creation in the WFG LASIK group. High and low contrast visual acuity, wavefront analysis, contrast sensitivity, and retinal straylight measurements were performed preoperatively and at 3, 6, and 12 months postoperatively. A third-generation straylight meter, C-Quant (Oculus Optikgeräte GmbH), was used for measuring intraocular straylight. Twelve months postoperatively, mean uncorrected distance visual acuity was -0.06 +/- 0.07 logMAR in the WFG LASIK group and -0.10 +/- 0.10 logMAR in the WFG PRK group. Mean preoperative intraocular straylight was 0.94 +/- 0.12 logs for the WFG LASIK group and 0.96 +/- 0.11 logs for the WFG PRK group. After 12 months, the mean straylight value was 1.01 +/- 0.1 log s for the WFG LASIK group and 0.97 +/- 0.12 log s for the WFG PRK group. No difference was found between techniques after 12 months (P = .306). No significant difference in photopic and mesopic contrast sensitivity between groups was noted. Intraocular straylight showed no statistically significant increase 1 year after WFG LASIK and WFG PRK. Higher order aberrations increased significantly after surgery for both groups. Nevertheless, WFG LASIK and WFG PRK yielded excellent visual acuity and contrast sensitivity performance without significant differences between techniques.
Visual functioning and quality of life among the older people in Hong Kong.
Leung, Jason C S; Kwok, Timothy C Y; Chan, Dicken C C; Yuen, Kay W K; Kwok, Anthony W L; Choy, Dicky T K; Lau, Edith M C; Leung, P C
2012-08-01
This study aimed to examine the association of visual functioning and health-related quality of life (HRQOL) among the older community in Hong Kong. This study used the baseline examination of a cohort study MrOs and MsOs (a large study for osteoporosis in men and women). This study was set in the Hong Kong community. A total of 4000 ambulatory community-dwelling Chinese men and women aged 65 years or above participated in this study. Health-related quality of life was assessed by Medical Outcomes Study Short Form-12 (SF-12), with physical component summary (PCS) and mental component summary (MCS) scores. Demographics, medical history, mental status, and quality of life were obtained from face-to-face interviews, using standard structured questionnaire. Visual functions (i.e., binocular visual acuity, contrast sensitivity, and stereopsis) were assessed by different visual tests after refraction corrections. Different visual functions were tested simultaneously in multiple ordinal logistic regression models. Better binocular visual acuity, contrast sensitivity, and stereopsis were associated with higher PCS. Visual acuity and contrast sensitivity was associated with PCS after adjustment of different visual functions and sex, age, education level, cognitive status, and history of diabetes in multivariate analysis, (OR = 0.73, 95% CI = 0.54 0.98) for low vision (≤6/24) compared with ≥6/9 in visual acuity and (OR = 1.34, 95% CI = 1.09 1.64) for contrast sensitivity row b 5-8 (best) compared with 0-1 (worst). MCS was only associated with visual acuity and contrast sensitivity, but no association was found after adjustment. Apparent association was found between visual functions and HRQOL among older community in Hong Kong. In addition to visual acuity, contrast sensitivity is also important, so eye care should also cover. Copyright © 2011 John Wiley & Sons, Ltd.
Alemtuzumab improves contrast sensitivity in patients with relapsing–remitting multiple sclerosis
Galetta, Steven L; Palmer, Jeffrey; Margolin, David H; Rizzo, Marco; Bilbruck, John; Balcer, Laura J
2013-01-01
Background: Alemtuzumab is a monoclonal antibody directed against CD52 that depletes T and B lymphocytes. Objective: To evaluate the treatment effect of alemtuzumab on low-contrast vision in relapsing–remitting multiple sclerosis (RRMS) patients. Methods: This was a pre-defined exploratory analysis within a randomized, rater-blinded trial (CAMMS223) that was run at 49 academic medical centers in the US and in Europe. Patients with untreated, early, RRMS (McDonald, n = 334) were randomized 1:1:1 to subcutaneous interferon beta-1a (IFNB-1a), or alemtuzumab 12 mg or 24 mg. Visual contrast sensitivity was measured for each eye at baseline and quarterly, with Pelli-Robson charts. Results: The eyes of patients in the pooled alemtuzumab group (versus IFNB-1a) had a greater than 2-fold higher rate of both 3-month and 6-month sustained visual improvement, of at least 0.3 log units (2 triplets, 6 letters) (At 3 months the hazard ratio (HR) = 2.26; CI = 1.19 to 4.31; P = 0.013; and at 6 months the HR = 2.44; CI =1.16 to 5.15; P = 0.019), and they had a lower risk of 3- and 6-month sustained worsening of at least 0.15 log units (1 triplet, 3 letters) (At 3 months the HR = 0.58; CI = 0.38 to 0.89; P = 0.012; and at 6 months HR = 0.55; CI=0.35 to 0.87; P = 0.010). Over the 36-month study period, the eyes of patients in the pooled alemtuzumab group improved in mean contrast sensitivity to a greater extent than those in the IFNB-1a group (0.080 log units versus 0.038 log units; P = 0.0102). Conclusions: Alemtuzumab was associated with a greater chance of improved contrast sensitivity in patients with RRMS and may delay the worsening of visual function. Contrast sensitivity testing was sensitive to treatment effects, even within an active comparator study design. These results support the validity of low-contrast vision testing as a clinical outcome in MS trials. PMID:23459567
Nonimmediate hypersensitivity reactions to iodinated contrast media.
Gómez, Enrique; Ariza, Adriana; Blanca-López, Natalia; Torres, Maria J
2013-08-01
To provide a detailed analysis of the latest findings on the mechanisms underlying the nonimmediate reactions to iodinated contrast media and comment on the recent advances in diagnosis, focusing on the roles of the skin test, drug provocation test (DPT), and lymphocyte transformation test (LTT). Several studies have reported new findings supporting an important role for T-lymphocytes in the nonimmediate reactions to iodinated contrast media. The LTT has been used as an in-vitro tool for diagnosis, but with variable results. However, the inclusion of autologous monocyte-derived dendritic cells as professional antigen-presenting cells has improved the sensitivity of this test. Regarding in-vivo diagnosis, although skin testing has been routine, it has now been shown that its sensitivity and negative predictive value are low. Recent studies have demonstrated that the DPT is a well tolerated and useful procedure that is necessary to confirm the diagnosis of nonimmediate hypersensitivity reactions to iodinated contrast media. Nonimmediate reactions to contrast media are usually T-cell mediated. Diagnosis is based on skin testing, although its sensitivity and negative predictive value are not optimal. Consequently, drug provocation testing is often needed to confirm the diagnosis and also to seek alternative contrast media that can be tolerated.
Measurement of visual contrast sensitivity
NASA Astrophysics Data System (ADS)
Vongierke, H. E.; Marko, A. R.
1985-04-01
This invention involves measurement of the visual contrast sensitivity (modulation transfer) function of a human subject by means of linear or circular spatial frequency pattern on a cathode ray tube whose contrast is automatically decreasing or increasing depending on the subject pressing or releasing a hand-switch button. The threshold of detection of the pattern modulation is found by the subject by adjusting the contrast to values which vary about the subject's threshold thereby determining the threshold and also providing by the magnitude of the contrast fluctuations between reversals some estimate of the variability of the subject's absolute threshold. The invention also involves the slow automatic sweeping of the spatial frequency of the pattern over the spatial frequencies after preset time intervals or after threshold has been defined at each frequency by a selected number of subject-determined threshold crossings; i.e., contrast reversals.
NASA Technical Reports Server (NTRS)
Shiota, T.; Jones, M.; Agler, D. A.; McDonald, R. W.; Marcella, C. P.; Qin, J. X.; Zetts, A. D.; Greenberg, N. L.; Cardon, L. A.; Sun, J. P.;
1999-01-01
Color Doppler images of aortic regurgitation (AR) flow acceleration, flow convergence (FC), and the vena contracta (VC) have been reported to be useful for evaluating severity of AR. However, clinical application of these methods has been limited because of the difficulty in clearly imaging the FC and VC. This study aimed to explore new windows for imaging the FC and VC to evaluate AR volumes in patients and to validate this in animals with chronic AR. Forty patients with AR and 17 hemodynamic states in 4 sheep with strictly quantified AR volumes were evaluated. A Toshiba SSH 380A with a 3.75-MHz transducer was used to image the FC and VC. After routine echo Doppler imaging, patients were repositioned in the right lateral decubitus position, and the FC and VC were imaged from high right parasternal windows. In only 15 of the 40 patients was it possible to image clearly and measure accurately the FC and VC from conventional (left decubitus) apical or parasternal views. In contrast, 31 of 40 patients had clearly imaged FC regions and VCs using the new windows. In patients, AR volumes derived from the FC and VC methods combined with continuous velocity agreed well with each other (r = 0.97, mean difference = -7.9 ml +/- 9.9 ml/beat). In chronic animal model studies, AR volumes derived from both the VC and the FC agreed well with the electromagnetically derived AR volumes (r = 0.92, mean difference = -1.3 +/- 4.0 ml/beat). By imaging from high right parasternal windows in the right decubitus position, complementary use of the FC and VC methods can provide clinically valuable information about AR volumes.
Shiota, T; Jones, M; Agler, D A; McDonald, R W; Marcella, C P; Qin, J X; Zetts, A D; Greenberg, N L; Cardon, L A; Sun, J P; Sahn, D J; Thomas, J D
1999-04-01
Color Doppler images of aortic regurgitation (AR) flow acceleration, flow convergence (FC), and the vena contracta (VC) have been reported to be useful for evaluating severity of AR. However, clinical application of these methods has been limited because of the difficulty in clearly imaging the FC and VC. This study aimed to explore new windows for imaging the FC and VC to evaluate AR volumes in patients and to validate this in animals with chronic AR. Forty patients with AR and 17 hemodynamic states in 4 sheep with strictly quantified AR volumes were evaluated. A Toshiba SSH 380A with a 3.75-MHz transducer was used to image the FC and VC. After routine echo Doppler imaging, patients were repositioned in the right lateral decubitus position, and the FC and VC were imaged from high right parasternal windows. In only 15 of the 40 patients was it possible to image clearly and measure accurately the FC and VC from conventional (left decubitus) apical or parasternal views. In contrast, 31 of 40 patients had clearly imaged FC regions and VCs using the new windows. In patients, AR volumes derived from the FC and VC methods combined with continuous velocity agreed well with each other (r = 0.97, mean difference = -7.9 ml +/- 9.9 ml/beat). In chronic animal model studies, AR volumes derived from both the VC and the FC agreed well with the electromagnetically derived AR volumes (r = 0.92, mean difference = -1.3 +/- 4.0 ml/beat). By imaging from high right parasternal windows in the right decubitus position, complementary use of the FC and VC methods can provide clinically valuable information about AR volumes.
Influence of retinopathy on the achromatic and chromatic vision of patients with type 2 diabetes
2014-01-01
Background Luminance contrast sensitivity and colour vision are considered to have great predictive value in the evaluation of type 2 diabetic retinopathy. However, these two visual characteristics have seldom been investigated in the same group of patients. In the present study we measured contrast sensitivity and colour vision in a group of patients with type 2 diabetes and correlated the results with estimates of common metabolic markers for the disease. A subgroup of the patients had no clinical signs of retinopathy. Methods The vision of 27 patients (n = 50 eyes) with type 2 diabetes, with retinopathy (n = 20 eyes), or without retinopathy (n = 30 eyes) were evaluated using two psychophysical tests, the Farnsworth–Munsell 100 hue test (FM 100), and measurements of the luminance contrast sensitivity at 11 spatial frequencies. The results were compared with measurements obtained from an age-matched control group (n = 32), and were correlated with the level of glycated haemoglobin, glycaemic level, and time of disease onset. Signs of retinopathy were identified during the ophthalmological examinations. Results Contrast sensitivity and colour vision impairments were present at different levels in diabetes patients. Eyes with retinopathy showed more severe vision loss than eyes without retinopathy. The FM 100 test was more sensitive for separation of patients from controls. Colour vision loss had no colour axes preference. The contrast sensitivity test appeared to have some advantage in differentiating patients with retinopathy from patients without retinopathy. Conclusions Both methods can be useful to follow the visual function of diabetic patients and should be used together to discriminate patients from controls, as well as to identify early signs of retinal damage. PMID:25174264
Mechanisms of the dimming and brightening aftereffects
Bosten, Jenny M.; MacLeod, Donald I. A.
2013-01-01
Abstract Dimming and brightening aftereffects occur after exposure to a temporal luminance sawtooth stimulus: A subsequently presented steady test field appears to become progressively dimmer or brighter, depending on the polarity of the adapting sawtooth. Although described as “dimming” and “brightening,” it is plausible that a component of the aftereffects is based on contrast changes rather than on luminance changes. We conducted two experiments to reveal any contrast component. In the first we investigated whether the aftereffects result from the same mechanism that causes a polarity-selective loss in contrast sensitivity following luminance sawtooth adaptation. We manipulated test contrast: If a component of the aftereffect results from a polarity selective loss of contrast sensitivity we would expect that the aftereffects would differ in magnitude depending on the contrast polarity of the test fields. We found no effect of test-field polarity. In the second experiment we used an adapting sawtooth with a polarity consistent in contrast but alternating in luminance in order to induce a potential equivalent aftereffect of contrast. Again, we found no evidence that the aftereffects result from contrast adaptation. In a third experiment, we used S-cone isolating stimuli to discover whether there are S-cone dimming and brightening aftereffects. We found no aftereffects. However, in a fourth experiment we replicated Krauskopf and Zaidi's (1986) finding that adaptation to S-cone sawtooth stimuli affects thresholds for increment and decrement detection. The mechanism underlying the dimming and brightening aftereffects thus seems to be independent of the mechanism underlying the concurrent polarity selective reductions in contrast sensitivity. PMID:23695534
Perceptual Improvement of Lexical Tones in Infants: Effects of Tone Language Experience
Tsao, Feng-Ming
2017-01-01
To learn words in a tonal language, tone-language learners should not only develop better abilities for perceiving consonants and vowels, but also for lexical tones. The divergent trend of enhancing sensitivity to native phonetic contrasts and reduced sensitivity to non-native phonetic contrast is theoretically essential to evaluate effects of listening to an ambient language on speech perception development. The loss of sensitivity in discriminating lexical tones among non-tonal language-learning infants was apparent between 6 and 12 months of age, but only few studies examined trends of differentiating native lexical tones in infancy. The sensitivity in discriminating lexical tones among 6–8 and 10–12 month-old Mandarin-learning infants (n = 120) was tested in Experiment 1 using three lexical tone contrasts of Mandarin. Facilitation of linguistic experience was shown in the tonal contrast (Tone 1 vs. 3), but both age groups performed similar in the other two tonal contrasts (Tone 2 vs. 4; Tone 2 vs. 3). In Experiment 2, 6–8 and 10–12 month-old Mandarin-learning infants (n = 90) were tested with tonal contrasts that have pitch contours either similar to or inverse from lexical tones in Mandarin, and perceptual improvement was shown only in a tonal contrast with familiar pitch contours (i.e., Tone 1 vs. 3). In Experiment 3, 6–8 and 10–12 month-old English-learning infants (n = 40) were tested with Tone 1 vs. 3 contrast of Mandarin and showed an improvement in the perception of non-native lexical tones. This study reveals that tone-language learning infants develop more accurate representations of lexical tones around their first birthday, and the results of both tone and non-tone language-learning infants imply that the rate of development depends on listening experience and the acoustical salience of specific tone contrasts. PMID:28443053
Sequential recruitment of study participants may inflate genetic heritability estimates.
Noce, Damia; Gögele, Martin; Schwienbacher, Christine; Caprioli, Giulia; De Grandi, Alessandro; Foco, Luisa; Platzgummer, Stefan; Pramstaller, Peter P; Pattaro, Cristian
2017-06-01
After the success of genome-wide association studies to uncover complex trait loci, attempts to explain the remaining genetic heritability (h 2 ) are mainly focused on unraveling rare variant associations and gene-gene or gene-environment interactions. Little attention is paid to the possibility that h 2 estimates are inflated as a consequence of the epidemiological study design. We studied the time series of 54 biochemical traits in 4373 individuals from the Cooperative Health Research In South Tyrol (CHRIS) study, a pedigree-based study enrolling ten participants/day over several years, with close relatives preferentially invited within the same day. We observed distributional changes of measured traits over time. We hypothesized that the combination of such changes with the pedigree structure might generate a shared-environment component with consequent h 2 inflation. We performed variance components (VC) h 2 estimation for all traits after accounting for the enrollment period in a linear mixed model (two-stage approach). Accounting for the enrollment period caused a median h 2 reduction of 4%. For 9 traits, the reduction was of >20%. Results were confirmed by a Bayesian Markov chain Monte Carlo analysis with all VCs included at the same time (one-stage approach). The electrolytes were the traits most affected by the enrollment period. The h 2 inflation was independent of the h 2 magnitude, laboratory protocol changes, and length of the enrollment period. The enrollment process may induce shared-environment effects even under very stringent and standardized operating procedures, causing h 2 inflation. Including the day of participation as a random effect is a sensitive way to avoid overestimation.
Contrast Sensitivity Function Scores, Choices of Illuminated Stand Magnifiers, and Reading
ERIC Educational Resources Information Center
Gerritsen, Bryan
2010-01-01
Far too often, professionals focus almost solely on individuals' needs for magnification level for reading. Visual acuities are measured and decisions are made for low vision devices largely on the basis of acuity levels. Contrast sensitivity function is often overlooked as a critical need for and predictor of the selection and preference for low…
Night vision in barn owls: visual acuity and contrast sensitivity under dark adaptation.
Orlowski, Julius; Harmening, Wolf; Wagner, Hermann
2012-12-06
Barn owls are effective nocturnal predators. We tested their visual performance at low light levels and determined visual acuity and contrast sensitivity of three barn owls by their behavior at stimulus luminances ranging from photopic to fully scotopic levels (23.5 to 1.5 × 10⁻⁶). Contrast sensitivity and visual acuity decreased only slightly from photopic to scotopic conditions. Peak grating acuity was at mesopic (4 × 10⁻² cd/m²) conditions. Barn owls retained a quarter of their maximal acuity when luminance decreased by 5.5 log units. We argue that the visual system of barn owls is designed to yield as much visual acuity under low light conditions as possible, thereby sacrificing resolution at photopic conditions.
Assessment of the reliability of standard automated perimetry in regions of glaucomatous damage.
Gardiner, Stuart K; Swanson, William H; Goren, Deborah; Mansberger, Steven L; Demirel, Shaban
2014-07-01
Visual field testing uses high-contrast stimuli in areas of severe visual field loss. However, retinal ganglion cells saturate with high-contrast stimuli, suggesting that the probability of detecting perimetric stimuli may not increase indefinitely as contrast increases. Driven by this concept, this study examines the lower limit of perimetric sensitivity for reliable testing by standard automated perimetry. Evaluation of a diagnostic test. A total of 34 participants with moderate to severe glaucoma; mean deviation at their last clinic visit averaged -10.90 dB (range, -20.94 to -3.38 dB). A total of 75 of the 136 locations tested had a perimetric sensitivity of ≤ 19 dB. Frequency-of-seeing curves were constructed at 4 nonadjacent visual field locations by the Method of Constant Stimuli (MOCS), using 35 stimulus presentations at each of 7 contrasts. Locations were chosen a priori and included at least 2 with glaucomatous damage but a sensitivity of ≥ 6 dB. Cumulative Gaussian curves were fit to the data, first assuming a 5% false-negative rate and subsequently allowing the asymptotic maximum response probability to be a free parameter. The strength of the relation (R(2)) between perimetric sensitivity (mean of last 2 clinic visits) and MOCS sensitivity (from the experiment) for all locations with perimetric sensitivity within ± 4 dB of each selected value, at 0.5 dB intervals. Bins centered at sensitivities ≥ 19 dB always had R(2) >0.1. All bins centered at sensitivities ≤ 15 dB had R(2) <0.1, an indication that sensitivities are unreliable. No consistent conclusions could be drawn between 15 and 19 dB. At 57 of the 81 locations with perimetric sensitivity <19 dB, including 49 of the 63 locations ≤ 15 dB, the fitted asymptotic maximum response probability was <80%, consistent with the hypothesis of response saturation. At 29 of these locations the asymptotic maximum was <50%, and so contrast sensitivity (50% response rate) is undefined. Clinical visual field testing may be unreliable when visual field locations have sensitivity below approximately 15 to 19 dB because of a reduction in the asymptotic maximum response probability. Researchers and clinicians may have difficulty detecting worsening sensitivity in these visual field locations, and this difficulty may occur commonly in patients with glaucoma with moderate to severe glaucomatous visual field loss. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
High sensitivity phase retrieval method in grating-based x-ray phase contrast imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Zhao; Gao, Kun; Chen, Jian
2015-02-15
Purpose: Grating-based x-ray phase contrast imaging is considered as one of the most promising techniques for future medical imaging. Many different methods have been developed to retrieve phase signal, among which the phase stepping (PS) method is widely used. However, further practical implementations are hindered, due to its complex scanning mode and high radiation dose. In contrast, the reverse projection (RP) method is a novel fast and low dose extraction approach. In this contribution, the authors present a quantitative analysis of the noise properties of the refraction signals retrieved by the two methods and compare their sensitivities. Methods: Using themore » error propagation formula, the authors analyze theoretically the signal-to-noise ratios (SNRs) of the refraction images retrieved by the two methods. Then, the sensitivities of the two extraction methods are compared under an identical exposure dose. Numerical experiments are performed to validate the theoretical results and provide some quantitative insight. Results: The SNRs of the two methods are both dependent on the system parameters, but in different ways. Comparison between their sensitivities reveals that for the refraction signal, the RP method possesses a higher sensitivity, especially in the case of high visibility and/or at the edge of the object. Conclusions: Compared with the PS method, the RP method has a superior sensitivity and provides refraction images with a higher SNR. Therefore, one can obtain highly sensitive refraction images in grating-based phase contrast imaging. This is very important for future preclinical and clinical implementations.« less
The Application of MRI for Depiction of Subtle Blood Brain Barrier Disruption in Stroke
Israeli, David; Tanne, David; Daniels, Dianne; Last, David; Shneor, Ran; Guez, David; Landau, Efrat; Roth, Yiftach; Ocherashvilli, Aharon; Bakon, Mati; Hoffman, Chen; Weinberg, Amit; Volk, Talila; Mardor, Yael
2011-01-01
The development of imaging methodologies for detecting blood-brain-barrier (BBB) disruption may help predict stroke patient's propensity to develop hemorrhagic complications following reperfusion. We have developed a delayed contrast extravasation MRI-based methodology enabling real-time depiction of subtle BBB abnormalities in humans with high sensitivity to BBB disruption and high spatial resolution. The increased sensitivity to subtle BBB disruption is obtained by acquiring T1-weighted MRI at relatively long delays (~15 minutes) after contrast injection and subtracting from them images acquired immediately after contrast administration. In addition, the relatively long delays allow for acquisition of high resolution images resulting in high resolution BBB disruption maps. The sensitivity is further increased by image preprocessing with corrections for intensity variations and with whole body (rigid+elastic) registration. Since only two separate time points are required, the time between the two acquisitions can be used for acquiring routine clinical data, keeping the total imaging time to a minimum. A proof of concept study was performed in 34 patients with ischemic stroke and 2 patients with brain metastases undergoing high resolution T1-weighted MRI acquired at 3 time points after contrast injection. The MR images were pre-processed and subtracted to produce BBB disruption maps. BBB maps of patients with brain metastases and ischemic stroke presented different patterns of BBB opening. The significant advantage of the long extravasation time was demonstrated by a dynamic-contrast-enhancement study performed continuously for 18 min. The high sensitivity of our methodology enabled depiction of clear BBB disruption in 27% of the stroke patients who did not have abnormalities on conventional contrast-enhanced MRI. In 36% of the patients, who had abnormalities detectable by conventional MRI, the BBB disruption volumes were significantly larger in the maps than in conventional MRI. These results demonstrate the advantages of delayed contrast extravasation in increasing the sensitivity to subtle BBB disruption in ischemic stroke patients. The calculated disruption maps provide clear depiction of significant volumes of BBB disruption unattainable by conventional contrast-enhanced MRI. PMID:21209786
The application of MRI for depiction of subtle blood brain barrier disruption in stroke.
Israeli, David; Tanne, David; Daniels, Dianne; Last, David; Shneor, Ran; Guez, David; Landau, Efrat; Roth, Yiftach; Ocherashvilli, Aharon; Bakon, Mati; Hoffman, Chen; Weinberg, Amit; Volk, Talila; Mardor, Yael
2010-12-26
The development of imaging methodologies for detecting blood-brain-barrier (BBB) disruption may help predict stroke patient's propensity to develop hemorrhagic complications following reperfusion. We have developed a delayed contrast extravasation MRI-based methodology enabling real-time depiction of subtle BBB abnormalities in humans with high sensitivity to BBB disruption and high spatial resolution. The increased sensitivity to subtle BBB disruption is obtained by acquiring T1-weighted MRI at relatively long delays (~15 minutes) after contrast injection and subtracting from them images acquired immediately after contrast administration. In addition, the relatively long delays allow for acquisition of high resolution images resulting in high resolution BBB disruption maps. The sensitivity is further increased by image preprocessing with corrections for intensity variations and with whole body (rigid+elastic) registration. Since only two separate time points are required, the time between the two acquisitions can be used for acquiring routine clinical data, keeping the total imaging time to a minimum. A proof of concept study was performed in 34 patients with ischemic stroke and 2 patients with brain metastases undergoing high resolution T1-weighted MRI acquired at 3 time points after contrast injection. The MR images were pre-processed and subtracted to produce BBB disruption maps. BBB maps of patients with brain metastases and ischemic stroke presented different patterns of BBB opening. The significant advantage of the long extravasation time was demonstrated by a dynamic-contrast-enhancement study performed continuously for 18 min. The high sensitivity of our methodology enabled depiction of clear BBB disruption in 27% of the stroke patients who did not have abnormalities on conventional contrast-enhanced MRI. In 36% of the patients, who had abnormalities detectable by conventional MRI, the BBB disruption volumes were significantly larger in the maps than in conventional MRI. These results demonstrate the advantages of delayed contrast extravasation in increasing the sensitivity to subtle BBB disruption in ischemic stroke patients. The calculated disruption maps provide clear depiction of significant volumes of BBB disruption unattainable by conventional contrast-enhanced MRI.
Visible contrast energy metrics for detection and discrimination
NASA Astrophysics Data System (ADS)
Ahumada, Albert J.; Watson, Andrew B.
2013-03-01
Contrast energy was proposed by Watson, Barlow, and Robson (Science, 1983) as a useful metric for representing luminance contrast target stimuli because it represents the detectability of the stimulus in photon noise for an ideal observer. We propose here the use of visible contrast energy metrics for detection and discrimination among static luminance patterns. The visibility is approximated with spatial frequency sensitivity weighting and eccentricity sensitivity weighting. The suggested weighting functions revise the Standard Spatial Observer (Watson and Ahumada, J. Vision, 2005) for luminance contrast detection , extend it into the near periphery, and provide compensation for duration. Under the assumption that the detection is limited only by internal noise, both detection and discrimination performance can be predicted by metrics based on the visible energy of the difference images.
Effect of variable tinted spectacle lenses on visual performance in control subjects.
Lee, Jason E; Stein, Jonathan J; Prevor, Meredith B; Seiple, William H; Holopigian, Karen; Greenstein, Vivienne C; Stenson, Susan M
2002-04-01
To evaluate quantitatively the effects of tinted spectacle lenses on visual performance in individuals without visual pathology. Twenty-five subjects were assessed by measuring contrast sensitivity with and without glare. Gray, brown, yellow, green, purple, and blue lens tints were evaluated. Measurements were repeated with each lens tint and with a clear lens, and the order was counterbalanced within and between subjects. Glare was induced with a modified brightness acuity tester. All subjects demonstrated an increase in contrast thresholds under glare conditions for all lens tints. However, purple and blue lens tints resulted in the least amount of contrast threshold increase; the yellow lens tint resulted in the largest contrast threshold increase. Purple and blue lens tints may improve contrast sensitivity in control subjects under glare conditions.
Brooks, P L; Frost, B J; Mason, J L; Gibson, D M
1987-03-01
The experiments described are part of an ongoing evaluation of the Queen's University Tactile Vocoder, a device that allows the acoustic waveform to be felt as a vibrational pattern on the skin. Two prelingually profoundly deaf teenagers reached criterion on a 50-word vocabulary (live voice, single speaker) using information obtained solely from the tactile vocoder with 28.5 and 24.0 hours of training. Immediately following word-learning experiments, subjects were asked to place 16 CVs into five phonemic categories (voiced & unvoiced stops, voiced & unvoiced fricatives, approximants). Average accuracy was 84.5%. Similar performance (89.6%) was obtained for placement of 12 VCs into four phonemic categories. Subjects were able to acquire some general rules about voicing and manner of articulation cues.
HCIT Contrast Performance Sensitivity Studies: Simulation Versus Experiment
NASA Technical Reports Server (NTRS)
Sidick, Erkin; Shaklan, Stuart; Krist, John; Cady, Eric J.; Kern, Brian; Balasubramanian, Kunjithapatham
2013-01-01
Using NASA's High Contrast Imaging Testbed (HCIT) at the Jet Propulsion Laboratory, we have experimentally investigated the sensitivity of dark hole contrast in a Lyot coronagraph for the following factors: 1) Lateral and longitudinal translation of an occulting mask; 2) An opaque spot on the occulting mask; 3) Sizes of the controlled dark hole area. Also, we compared the measured results with simulations obtained using both MACOS (Modeling and Analysis for Controlled Optical Systems) and PROPER optical analysis programs with full three-dimensional near-field diffraction analysis to model HCIT's optical train and coronagraph.
Haji-Momenian, S; Parkinson, W; Khati, N; Brindle, K; Earls, J; Zeman, R K
2018-06-01
To determine the sensitivity, specificity, and predictive values of single-energy non-contrast hepatic steatosis criteria on dual-energy virtual non-contrast (VNC) images. Forty-eight computed tomography (CT) examinations, which included single-energy non-contrast (TNC) and contrast-enhanced dual-energy CT angiography (CTA) of the abdomen, were enrolled. VNC images were reconstructed from the CTA. Region of interest (ROI) attenuations were measured in the right and left hepatic lobes, spleen, and aorta on TNC and VNC images. The right and left hepatic lobes were treated as separate samples. Steatosis was diagnosed based on TNC liver attenuation of ≤40 HU or liver attenuation index (LAI) of ≤-10 HU, which are extremely specific and predictive for moderate to severe steatosis. The sensitivity, specificity, and predictive values of VNC images for steatosis were calculated. VNC-TNC deviations were correlated with aortic enhancement and patient water equivalent diameter (PWED). Thirty-two liver ROIs met steatosis criteria based on TNC attenuation; VNC attenuation had sensitivity, specificity, and a positive predictive value of 66.7%, 100%, and 100%, respectively. Twenty-one liver ROIs met steatosis criteria based on TNC LAI. VNC LAI had sensitivity, specificity, and positive predictive values of 61.9%, 90.7%, and 65%, respectively. Hepatic and splenic VNC-TNC deviations did not correlate with one another (R 2 =0.08), aortic enhancement (R 2 <0.06) or PWED (R 2 <0.09). Non-contrast hepatic attenuation criteria is extremely specific and positively predictive for moderate to severe steatosis on VNC reconstructions from the arterial phase. Hepatic attenuation performs better than LAI criteria. VNC deviations are independent of aortic enhancement and PWED. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Streeter, Jason E.; Gessner, Ryan; Miles, Iman; Dayton, Paul A.
2010-01-01
Molecular imaging with ultrasound relies on microbubble contrast agents (MCAs) selectively adhering to a ligand-specific target. Prior studies have shown that only small quantities of microbubbles are retained at their target sites, therefore, enhancing contrast sensitivity to low concentrations of microbubbles is essential to improve molecular imaging techniques. In order to assess the effect of MCA diameter on imaging sensitivity, perfusion and molecular imaging studies were performed with microbubbles of varying size distributions. To assess signal improvement and MCA circulation time as a function of size and concentration, blood perfusion was imaged in rat kidneys using nontargeted size-sorted MCAs with a Siemens Sequoia ultrasound system (Siemans, Mountain View, CA) in cadence pulse sequencing (CPS) mode. Molecular imaging sensitivity improvements were studied with size-sorted αvβ3-targeted bubbles in both fibrosarcoma and R3230 rat tumor models. In perfusion imaging studies, video intensity and contrast persistence was ≈8 times and ≈3 times greater respectively, for “sorted 3-micron” MCAs (diameter, 3.3 ± 1.95 μm) when compared to “unsorted” MCAs (diameter, 0.9 ± 0.45 μm) at low concentrations. In targeted experiments, application of sorted 3-micron MCAs resulted in a ≈20 times video intensity increase over unsorted populations. Tailoring size-distributions results in substantial imaging sensitivity improvement over unsorted populations, which is essential in maximizing sensitivity to small numbers of MCAs for molecular imaging. PMID:20236606
da Costa, Marcelo Fernandes; Júnior, Augusto Paranhos; Lottenberg, Claudio Luiz; Castro, Leonardo Cunha; Ventura, Dora Fix
2017-12-01
The purpose of this study was to measure luminance contrast sensitivity and color vision thresholdfs in normal subjects using a blue light filter lens and transparent intraocular lens material. Monocular luminance grating contrast sensitivity was measured with Psycho for Windows (version 2.36; Cambridge Research Systems) at 3.0, 6.0, 12.0, 20.0, and 30.0 cycles per degree of visual angle (cpd) in 15 normal subjects (eight female), with a mean age of 21.6 years (SD = 3.8 years). Chromatic discrimination was assessed with the Cambridge colour test (CCT) along the protan, deutan, and tritan color confusion axes. Both tests were performed in a darkened room under two situations: with a transparent lens and with blue light filter lens. Subjective impressions were taken by subjects regarding their visual experience under both conditions. No difference was found between the luminance contrast sensitivity measured with transparent and blue light filter. However, 13/15 (87%) of the subjects reported more comfortable vision with the blue filter. In the color vision test, tritan thresholds were significantly higher for the blue filter compared with the transparent filter (p = 0.003). For protan and deutan thresholds no differences were found. Blue-yellow color vision is impaired with the blue light filter, and no impairment occurs with the transparent filter. No significant differences in thresholds were found in the luminance contrast sensitivity comparing the blue light and transparent filters. The impact of short wavelength light filtering on intrinsically photosensitive retinal ganglion cells is also discussed.
Mejía-Rivera, S; Pérez-Marroquín, S A; Cortés-González, R; Medina-Franco, H
2018-03-07
Esophagectomy is a highly invasive surgery and one of its postoperative complications is anastomotic leakage, occurring in 53% of cases. The aim of the present study was to determine the sensitivity of the contrast-enhanced swallow study as a method for diagnosing anastomotic leak in patients that underwent esophagectomy. The present retrospective study included the case records of patients that underwent esophagectomy with reconstruction and cervical anastomosis at the Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán within the time frame of January 1, 2000 and May 31, 2006. Demographic, clinical, and laboratory data emphasizing clinical and radiographic anastomotic leak detection were identified. Descriptive statistics were carried out and contrast-enhanced swallow study sensitivity for diagnosing leakage was calculated. Seventy patients were included in the analysis. The mean age of the patients was 50.6 years, 51 of the patients were men (72.86%), and 19 were women (27.14%). Indications for surgery were benign lesion in 29 patients (41.4%) and malignant lesion in 41 (58.6%). A total of 44.3% of the patients presented with a comorbidity, with diabetes mellitus and high blood pressure standing out. Thirty patients (42.85%) presented with anastomotic leak. Contrast-enhanced swallow study sensitivity for leak detection was 43.33%. The diagnostic sensitivity of the contrast-enhanced swallow study was very low. Therefore, we recommend the discontinuation of its routine use as a method for diagnosing anastomotic leaks. Copyright © 2018 Asociación Mexicana de Gastroenterología. Publicado por Masson Doyma México S.A. All rights reserved.
Hagberg, Gisela E; Mamedov, Ilgar; Power, Anthony; Beyerlein, Michael; Merkle, Hellmut; Kiselev, Valerij G; Dhingra, Kirti; Kubìček, Vojtĕch; Angelovski, Goran; Logothetis, Nikos K
2014-01-01
Calcium-sensitive MRI contrast agents can only yield quantitative results if the agent concentration in the tissue is known. The agent concentration could be determined by diffusion modeling, if relevant parameters were available. We have established an MRI-based method capable of determining diffusion properties of conventional and calcium-sensitive agents. Simulations and experiments demonstrate that the method is applicable both for conventional contrast agents with a fixed relaxivity value and for calcium-sensitive contrast agents. The full pharmacokinetic time-course of gadolinium concentration estimates was observed by MRI before, during and after intracerebral administration of the agent, and the effective diffusion coefficient D* was determined by voxel-wise fitting of the solution to the diffusion equation. The method yielded whole brain coverage with a high spatial and temporal sampling. The use of two types of MRI sequences for sampling of the diffusion time courses was investigated: Look-Locker-based quantitative T(1) mapping, and T(1) -weighted MRI. The observation times of the proposed MRI method is long (up to 20 h) and consequently the diffusion distances covered are also long (2-4 mm). Despite this difference, the D* values in vivo were in agreement with previous findings using optical measurement techniques, based on observation times of a few minutes. The effective diffusion coefficient determined for the calcium-sensitive contrast agents may be used to determine local tissue concentrations and to design infusion protocols that maintain the agent concentration at a steady state, thereby enabling quantitative sensing of the local calcium concentration. Copyright © 2014 John Wiley & Sons, Ltd.
Gong, Rui; Yang, Bi; Liu, Longqian; Dai, Yun; Zhang, Yudong; Zhao, Haoxin
2016-06-01
We conducted this study to explore the influence of the ocular residual aberrations changes on contrast sensitivity(CS)function in eyes undergoing orthokeratology using adaptive optics technique.Nineteen subjects’ nineteen eyes were included in this study.The subjects were between 12 and 20years(14.27±2.23years)of age.An adaptive optics(AO)system was adopted to measure and compensate the residual aberrations through a 4-mm artificial pupil,and at the same time the contrast sensitivities were measured at five spatial frequencies(2,4,8,16,and 32 cycles per degree).The CS measurements with and without AO correction were completed.The sequence of the measurements with and without AO correction was randomly arranged without informing the observers.A two-interval forced-choice procedure was used for the CS measurements.The paired t-test was used to compare the contrast sensitivity with and without AO correction at each spatial frequency.The results revealed that the AO system decreased the mean total root mean square(RMS)from 0.356μm to 0.160μm(t=10.517,P<0.001),and the mean total higher-order RMS from 0.246μm to 0.095μm(t=10.113,P<0.001).The difference in log contrast sensitivity with and without AO correction was significant only at 8cpd(t=-2.51,P=0.02).Thereby we concluded that correcting the ocular residual aberrations using adaptive optics technique could improve the contrast sensitivity function at intermediate spatial frequency in patients undergoing orthokeratology.
Rasta, Seyed Hossein; Partovi, Mahsa Eisazadeh; Seyedarabi, Hadi; Javadzadeh, Alireza
2015-01-01
To investigate the effect of preprocessing techniques including contrast enhancement and illumination correction on retinal image quality, a comparative study was carried out. We studied and implemented a few illumination correction and contrast enhancement techniques on color retinal images to find out the best technique for optimum image enhancement. To compare and choose the best illumination correction technique we analyzed the corrected red and green components of color retinal images statistically and visually. The two contrast enhancement techniques were analyzed using a vessel segmentation algorithm by calculating the sensitivity and specificity. The statistical evaluation of the illumination correction techniques were carried out by calculating the coefficients of variation. The dividing method using the median filter to estimate background illumination showed the lowest Coefficients of variations in the red component. The quotient and homomorphic filtering methods after the dividing method presented good results based on their low Coefficients of variations. The contrast limited adaptive histogram equalization increased the sensitivity of the vessel segmentation algorithm up to 5% in the same amount of accuracy. The contrast limited adaptive histogram equalization technique has a higher sensitivity than the polynomial transformation operator as a contrast enhancement technique for vessel segmentation. Three techniques including the dividing method using the median filter to estimate background, quotient based and homomorphic filtering were found as the effective illumination correction techniques based on a statistical evaluation. Applying the local contrast enhancement technique, such as CLAHE, for fundus images presented good potentials in enhancing the vasculature segmentation.
Visual function at altitude under night vision assisted conditions.
Vecchi, Diego; Morgagni, Fabio; Guadagno, Anton G; Lucertini, Marco
2014-01-01
Hypoxia, even mild, is known to produce negative effects on visual function, including decreased visual acuity and sensitivity to contrast, mostly in low light. This is of special concern when night vision devices (NVDs) are used during flight because they also provide poor images in terms of resolution and contrast. While wearing NVDs in low light conditions, 16 healthy male aviators were exposed to a simulated altitude of 12,500 ft in a hypobaric chamber. Snellen visual acuity decreased in normal light from 28.5 +/- 4.2/20 (normoxia) to 37.2 +/- 7.4/20 (hypoxia) and, in low light, from 33.8 +/- 6.1/20 (normoxia) to 42.2 +/- 8.4/20 (hypoxia), both at a significant level. An association was found between blood oxygen saturation and visual acuity without significance. No changes occurred in terms of sensitivity to contrast. Our data demonstrate that mild hypoxia is capable of affecting visual acuity and the photopic/high mesopic range of NVD-aided vision. This may be due to several reasons, including the sensitivity to hypoxia of photoreceptors and other retinal cells. Contrast sensitivity is possibly preserved under NVD-aided vision due to its dependency on the goggles' gain.
Richman, Jesse; Zangalli, Camila; Lu, Lan; Wizov, Sheryl S; Spaeth, Eric; Spaeth, George L
2015-01-01
(1) To determine the ability of a novel, internet-based contrast sensitivity test titled the Spaeth/Richman Contrast Sensitivity Test (SPARCS) to identify patients with glaucoma. (2) To determine the test-retest reliability of SPARCS. A prospective, cross-sectional study of patients with glaucoma and controls was performed. Subjects were assessed by SPARCS and the Pelli-Robson chart. Reliability of each test was assessed by the intraclass correlation coefficient and the coefficient of repeatability. Sensitivity and specificity for identifying glaucoma was also evaluated. The intraclass correlation coefficient for SPARCS was 0.97 and 0.98 for Pelli-Robson. The coefficient of repeatability for SPARCS was ±6.7% and ±6.4% for Pelli-Robson. SPARCS identified patients with glaucoma with 79% sensitivity and 93% specificity. SPARCS has high test-retest reliability. It is easily accessible via the internet and identifies patients with glaucoma well. NCT01300949. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Turner, Travis H
2005-03-30
An increasingly large corpus of clinical and experimental neuropsychological research has demonstrated the utility of measuring visual contrast sensitivity. Unfortunately, existing means of measuring contrast sensitivity can be prohibitively expensive, difficult to standardize, or lack reliability. Additionally, most existing tests do not allow full control over important characteristics, such as off-angle rotations, waveform, contrast, and spatial frequency. Ideally, researchers could manipulate characteristics and display stimuli in a computerized task designed to meet experimental needs. Thus far, 256-bit color limitation in standard cathode ray tube (CRT) monitors has been preclusive. To this end, the pointillism method (PM) was developed. Using MATLAB software, stimuli are created based on both mathematical and stochastic components, such that differences in regional luminance values of the gradient field closely approximate the desired contrast. This paper describes the method and examines its performance in sine and square-wave image sets from a range of contrast values. Results suggest the utility of the method for most experimental applications. Weaknesses in the current version, the need for validation and reliability studies, and considerations regarding applications are discussed. Syntax for the program is provided in an appendix, and a version of the program independent of MATLAB is available from the author.
Zhou, Xinyi Y; Tay, Zhi Wei; Chandrasekharan, Prashant; Yu, Elaine Y; Hensley, Daniel W; Orendorff, Ryan; Jeffris, Kenneth E; Mai, David; Zheng, Bo; Goodwill, Patrick W; Conolly, Steven M
2018-05-10
Magnetic particle imaging (MPI) is an emerging ionizing radiation-free biomedical tracer imaging technique that directly images the intense magnetization of superparamagnetic iron oxide nanoparticles (SPIOs). MPI offers ideal image contrast because MPI shows zero signal from background tissues. Moreover, there is zero attenuation of the signal with depth in tissue, allowing for imaging deep inside the body quantitatively at any location. Recent work has demonstrated the potential of MPI for robust, sensitive vascular imaging and cell tracking with high contrast and dose-limited sensitivity comparable to nuclear medicine. To foster future applications in MPI, this new biomedical imaging field is welcoming researchers with expertise in imaging physics, magnetic nanoparticle synthesis and functionalization, nanoscale physics, and small animal imaging applications. Copyright © 2018 Elsevier Ltd. All rights reserved.
The sensitivity of radiography of the postoperative stomach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ott, D.J.; Munitz, H.A.; Gelfand, D.W.
1982-09-01
The results of radiology and endoscopy were compared in 140 patients who had undergone gastric surgery for ulcer disease. Of 74 patients who were examined with single-contrast radiography, 37 had abnormalities that were demonstrated endoscopically. The radiographic sensitivities in these patients were: gastritis 2/22 (9%); ulcer 3/5 (60%); obstruction 8/8 (100%); and miscellaneous abnormalities 2/2 (100%). The predictive accuracy of a diagnois of ulcer was 38%. Of the 66 patients who were examined with double-contrast radiography, 33 abnormalities were found with endoscopy. The radiographic sensitivities were: gastritis 3/13 (23%); ulcer 7/10 (70%); obstruction 4/4 (100%); and miscellaneous abnormalities 6/6 (100%).more » The predictive accuracy of a diagnosis of ulcer was 44%. Radiology appears to be unreliable in diagnosing gastritis and recurrent ulceration in the post-operation stomach. The double-contrast technique does not offer significant improvement over the single-contrast method in evaluating these postoperative problems.« less
Delayed rectifier K channels contribute to contrast adaptation in mammalian retinal ganglion cells
Weick, Michael; Demb, Jonathan B.
2011-01-01
SUMMARY Retinal ganglion cells adapt by reducing their sensitivity during periods of high contrast. Contrast adaptation in the firing response depends on both presynaptic and intrinsic mechanisms. Here, we investigated intrinsic mechanisms for contrast adaptation in OFF Alpha ganglion cells in the in vitro guinea pig retina. Using either visual stimulation or current injection, we show that brief depolarization evoked spiking and suppressed firing during subsequent depolarization. The suppression could be explained by Na channel inactivation, as shown in salamander cells. However, brief hyperpolarization in the physiological range (5–10 mV) also suppressed firing during subsequent depolarization. This suppression was sensitive selectively to blockers of delayed-rectifier K channels (KDR). Somatic membrane patches showed TEA-sensitive KDR currents with activation near −25 mV and removal of inactivation at voltages negative to Vrest. Brief periods of hyperpolarization apparently remove KDR inactivation and thereby increase the channel pool available to suppress excitability during subsequent depolarization. PMID:21745646
Delayed-rectifier K channels contribute to contrast adaptation in mammalian retinal ganglion cells.
Weick, Michael; Demb, Jonathan B
2011-07-14
Retinal ganglion cells adapt by reducing their sensitivity during periods of high contrast. Contrast adaptation in the firing response depends on both presynaptic and intrinsic mechanisms. Here, we investigated intrinsic mechanisms for contrast adaptation in OFF Alpha ganglion cells in the in vitro guinea pig retina. Using either visual stimulation or current injection, we show that brief depolarization evoked spiking and suppressed firing during subsequent depolarization. The suppression could be explained by Na channel inactivation, as shown in salamander cells. However, brief hyperpolarization in the physiological range (5-10 mV) also suppressed firing during subsequent depolarization. This suppression was selectively sensitive to blockers of delayed-rectifier K channels (K(DR)). In somatic membrane patches, we observed tetraethylammonium-sensitive K(DR) currents that activated near -25 mV. Recovery from inactivation occurred at potentials hyperpolarized to V(rest). Brief periods of hyperpolarization apparently remove K(DR) inactivation and thereby increase the channel pool available to suppress excitability during subsequent depolarization. Copyright © 2011 Elsevier Inc. All rights reserved.
Psychophysical and perceptual performance in a simulated-scotoma model of human eye injury
NASA Astrophysics Data System (ADS)
Brandeis, R.; Egoz, I.; Peri, D.; Sapiens, N.; Turetz, J.
2008-02-01
Macular scotomas, affecting visual functioning, characterize many eye and neurological diseases like AMD, diabetes mellitus, multiple sclerosis, and macular hole. In this work, foveal visual field defects were modeled, and their effects were evaluated on spatial contrast sensitivity and a task of stimulus detection and aiming. The modeled occluding scotomas, of different size, were superimposed on the stimuli presented on the computer display, and were stabilized on the retina using a mono Purkinje Eye-Tracker. Spatial contrast sensitivity was evaluated using square-wave grating stimuli, whose contrast thresholds were measured using the method of constant stimuli with "catch trials". The detection task consisted of a triple conjunctive visual search display of: size (in visual angle), contrast and background (simple, low-level features vs. complex, high-level features). Search/aiming accuracy as well as R.T. measures used for performance evaluation. Artificially generated scotomas suppressed spatial contrast sensitivity in a size dependent manner, similar to previous studies. Deprivation effect was dependent on spatial frequency, consistent with retinal inhomogeneity models. Stimulus detection time was slowed in complex background search situation more than in simple background. Detection speed was dependent on scotoma size and size of stimulus. In contrast, visually guided aiming was more sensitive to scotoma effect in simple background search situation than in complex background. Both stimulus aiming R.T. and accuracy (precision targeting) were impaired, as a function of scotoma size and size of stimulus. The data can be explained by models distinguishing between saliency-based, parallel and serial search processes, guiding visual attention, which are supported by underlying retinal as well as neural mechanisms.
Huang, Chang-Bing; Lu, Zhong-Lin; Zhou, Yifeng
2010-01-01
What underlies contrast sensitivity improvements in adults with anisometropic amblyopia following perceptual learning in grating contrast detection? In this paper, we adopted the external noise approach (Z.-L. Lu & B. A. Dosher, 1998) to identify the mechanisms underlying perceptual learning in adults with anisometropic amblyopia. By measuring contrast thresholds in a range of external noise conditions at two performance levels (79.3% and 70.7%), we found that a mixture of internal additive noise reduction and external noise exclusion underlay training induced contrast sensitivity improvements in adults with anisometropic amblyopia. In comparison, normal adults exhibited only small amount of external noise exclusion under the same training conditions. The results suggest that neural plasticity may be more robust in amblyopia, lending further support of perceptual learning as a potential treatment for adult amblyopia. PMID:20053087
Normandin, J J; Murphy, A Z
2011-02-23
Little is known regarding the descending inhibitory control of genital reflexes such as ejaculation and vaginal contractions. The brainstem nucleus paragigantocellularis (nPGi) projects bilaterally to the lumbosacral motoneuron pools that innervate the genital musculature of both male and female rats. Electrolytic nPGi lesions facilitate ejaculation in males, leading to the hypothesis that the nPGi is the source of descending inhibition to genital reflexes. However, the function of the nPGi in female sexual behavior remains to be elucidated. To this end, male and female rats received bilateral excitotoxic fiber-sparing lesions of the nPGi, and sexual behavior and sexual behavior-induced Fos expression were examined. In males, nPGi lesions facilitated copulation, supporting the hypothesis that the nPGi, and not fibers-of-passage, is the source of descending inhibition of genital reflexes in male rats. nPGi lesions in males did not alter sexual behavior-induced Fos expression in any brain region examined. nPGi-lesioned females spent significantly less time mating with stimulus males and had significantly longer ejaculation-return latencies compared to baseline. These results did not significantly differ from control females, but this trend warranted further analysis of the reinforcing value of sexual behavior. Both lesioned and non-lesioned females formed a conditioned place preference (CPP) for artificial vaginocervical stimulation (aVCS). However, post-reinforcement, nPGi-lesioned females did not differ in the percentage of time spent in the non-reinforced chamber versus the reinforced chamber, suggesting a weakened CPP for aVCS. nPGi lesions in females reduced sexual behavior-induced Fos expression throughout the hypothalamus and amygdala. Taken together, these results suggest that while nPGi lesions in males facilitate copulation, such lesions in females attenuate several aspects of sexual behavior resulting in a reduction in the rewarding value of copulation that may be mediated by nPGi control of genital reflexes. This work has important implications for the understanding and treatment of sexual dysfunction in people including delayed/premature ejaculation, involuntary vaginal spasms, and pain during intercourse. Published by Elsevier Ltd.
Cantera and Cantera Electrolyte Thermodynamics Objects
DOE Office of Scientific and Technical Information (OSTI.GOV)
John Hewson, Harry Moffat
Cantera is a suite of object-oriented software tools for problems involving chemical kinetics, thermodynamics, and/or transport processes. It is a multi-organizational effort to create and formulate high quality 0D and 1D constitutive modeling tools for reactive transport codes.Institutions involved with the effort include Sandia, MIT, Colorado School of Mines, U. Texas, NASA, and Oak Ridge National Labs. Specific to Sandia's contributions, the Cantera Electrolyte Thermo Objects (CETO) packages is comprised of add-on routines for Cantera that handle electrolyte thermochemistry and reactions within the overall Cantera package. Cantera is a C++ Cal Tech code that handles gas phase species transport, reaction,more » and thermodynamics. With this addition, Cantera can be extended to handle problems involving liquid phase reactions and transport in electrolyte systems, and phase equilibrium problemsinvolving concentrated electrolytes and gas/solid phases. A full treatment of molten salt thermodynamics and transport has also been implemented in CETO. The routines themselves consist of .cpp and .h files containing C++ objects that are derived from parent Cantera objects representing thermodynamic functions. They are linked unto the main Cantera libraries when requested by the user. As an addendum to the main thermodynamics objects, several utility applications are provided. The first is multiphase Gibbs free energy minimizer based on the vcs algorithm, called vcs_cantera. This code allows for the calculation of thermodynamic equilibrium in multiple phases at constant temperature and pressure. Note, a similar code capability exists already in Cantera. This version follows the same algorithm, but gas a different code-base starting point, and is used as a research tool for algorithm development. The second program, cttables, prints out tables of thermodynamic and kinetic information for thermodynamic and kinetic objects within Cantera. This program serves as a "Get the numbers out" utility for Cantera, and as such it is very useful as a verification tool. These add-on utilities are encapsulated into a directory structure named cantera_apps, whose installation uses autoconf and also utilizes Cantera's application environment (i.e., they utilize Cantera as a library).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Al-Ward, S; Kim, A; McCann, C
2016-06-15
Purpose: To simulate tumor tracking in an Elekta MRI-linac (MRL) and to compare this tracking method with our current ITV approach in terms of OAR sparing for lung cancer patients. Methods: Five SABR-NSCLC patients with central lung tumors were selected for reasons of potential enhancement of tumor-tissue delineation using MRI. The Monaco TPS was used to compare the current clinical ITV approach to a simulated, novel tracking method which used a 7MV MRL beam in the presence of an orthogonal 1.5 T magnetic field (4D-MRL method). In the simulated tracking scenario, achieved using the virtual couch shift (VCS), the PTVmore » was defined using an isotropic 5mm margin applied to the GTV of each phase, as acquired from an 8-phase amplitude-binned 4DCT. These VCS plans were optimized and weighted on each phase. The dose weighting was performed using the patient-specific breathing traces. The doses were accumulated on the inhale phase. The two methods were compared by assessing the OAR DVHs. Results: The 4D-MRL method resulted in a reduced target volume (by an average of 29% over all patients). The benefits of using an MRL tracking system depended on the tumor motion amplitude and the relative OAR motion (ROM) to the target. The reduction in mean doses to parallel organs was up to 3 Gy for the heart and 2.1 Gy for the lung. The reductions in maximum doses to serial organs were up to 9.4 Gy, 5.6 Gy, and 8.7 Gy for the esophagus, spinal cord, and the trachea, respectively. Serial organs benefited from MRL tracking when the ROM was ≥ 0.3 cm despite small tumor motion amplitude in some cases. Conclusions: This work demonstrated the potential benefit for an MRL tracking system to spare OARs in SABR-NSCLC patients with central tumors. The benefits are embodied in the target volume reduction. This project was made possible with the financial support of Elekta.« less
Roy R. Rosenberger; Carl J. Houtman
2000-01-01
The USPS Image Analysis (IA) protocol recommends the use of hydrophobic dyes to develop contrast between pressure sensitive adhesive (PSA) particles and cellulosic fibers before using a dirt counter to detect all contaminants that have contrast with the handsheet background. Unless the sample contains no contaminants other than those of interest, two measurement steps...
Suprathreshold Contrast Sensitivity Vision Test Chart
1991-07-14
with data collected on patients having amblyopia , glaucoma and macular degeneration showed that the SCTS may be effectively used as an initial...dramatically in certain cases of abnormal vision, such as amblyopia (Ginsburg, 1978, 1981; Hess, Bradley and Piotrowski, 1983; Loshin and Levi, 1983). The...combination of frequencies. Amblyopia results in marked losses of contrast sensitivity particularly at high spatial frequencies, but may also result in
Performance Sensitivity Studies on the PIAA Implementation of the High-Contrast Imaging Testbed
NASA Technical Reports Server (NTRS)
Sidick, Erkin; Lou, John; Shaklan, Stuart; Levine, Marie
2010-01-01
This slide presentation reviews the sensitivity studies on the Phase-Induced Amplitude Apodization (PIAA), or pupil mapping using the High-Contrast Imaging Testbed (HCIT). PIAA is a promising technique in high-dynamic range stellar coronagraph. This presentation reports on the investigation of the effects of the phase and rigid-body errors of various optics on the narrowband contrast performance of the PIAA/HCIT hybrid system. The results have shown that the 2-step wavefront control method utilizing 2-DMs is quite effective in compensating the effects of realistic phase and rigid-body errors of various optics
Effects of experimental exposure to triethylamine on vision and the eye
Jarvinen, P.; Engstrom, K.; Riihimaki, V.; Ruusuvaara, P.; Setala, K.
1999-01-01
OBJECTIVES: To determine the effect of triethylamine (TEA) on the cornea and to evaluate the cause of blurred vision. To find the lowest observed effect concentration of exposure to TEA. METHODS: Four people were exposed to TEA for 4 hours at concentrations of 40.6, 6.5, and 3.0 mg/m3. Before and after every exposure, symptoms and ocular microscopy findings were recorded. Binocular visual acuity and contrast sensitivity at 2.5% contrast were also measured. Also, before and after the 40.6 mg/m3 exposure, corneal thickness was measured and ocular dimensions were recorded by ultrasonography, endothelial cells of the cornea were analysed, and serum and lacrimal specimens were collected for the analysis of TEA. RESULTS: After exposure to 40.6 mg/m3 TEA there was a marked oedema in the corneal epithelium and subepithelial microcysts. However, corneal thickness increased only minimally because of the epithelial oedema. The lacrimal concentrations of TEA were, on average (range) 41 (18-83) times higher than the serum TEA concentrations. The vision was blurred in all subjects and visual acuity and contrast sensitivity had decreased in three of the four subjects. After exposure to TEA at 6.5 mg/m3 two subjects experienced symptoms, and contrast sensitivity had decreased in three of the four subjects. There were no symptoms or decreases in contrast sensitivity after exposure to a TEA concentration of 3.0 mg/m3. CONCLUSIONS: TEA caused a marked oedema and microcysts in corneal epithelium but only minor increases in corneal thickness. The effects may be mediated by the lacrimal fluid owing to its high TEA concentration. Four hour exposure to a TEA concentration of 3.0 mg/m3 seemed to cause no effects, whereas exposure to 6.5 mg/m3 for the same period caused blurred vision and a decrease in contrast sensitivity. PMID:10341738
NASA Astrophysics Data System (ADS)
Husseini, Naji Sami
Single-crystal nickel-base superalloys are ubiquitous in demanding turbine-blade applications, and they owe their remarkable resilience to their dendritic, hierarchical microstructure and complex composition. During normal operations, they endure rapid low-stress vibrations that may initiate fatigue cracks. This failure mode in the very high-cycle regime is poorly understood, in part due to inadequate testing and diagnostic equipment. Phase-contrast imaging with coherent synchrotron x rays, however, is an emergent technique ideally suited for dynamic processes such as crack initiation and propagation. A specially designed portable ultrasonic-fatigue apparatus, coupled with x-ray radiography, allows real-time,
Sensitivity of photoacoustic microscopy
Yao, Junjie; Wang, Lihong V.
2014-01-01
Building on its high spatial resolution, deep penetration depth and excellent image contrast, 3D photoacoustic microscopy (PAM) has grown tremendously since its first publication in 2005. Integrating optical excitation and acoustic detection, PAM has broken through both the optical diffusion and optical diffraction limits. PAM has 100% relative sensitivity to optical absorption (i.e., a given percentage change in the optical absorption coefficient yields the same percentage change in the photoacoustic amplitude), and its ultimate detection sensitivity is limited only by thermal noise. Focusing on the engineering aspects of PAM, this Review discusses the detection sensitivity of PAM, compares the detection efficiency of different PAM designs, and summarizes the imaging performance of various endogenous and exogenous contrast agents. It then describes representative PAM applications with high detection sensitivity, and outlines paths to further improvement. PMID:25302158
Feizi, Sepehr; Javadi, Mohammad Ali; Mohammad-Rabei, Hossein
2016-02-01
To identify causes of reduced visual acuity and contrast sensitivity after big-bubble deep anterior lamellar keratoplasty (DALK) in keratoconus. Prospective interventional case series. This study included 36 eyes in 36 patients with keratoconus who underwent DALK using the big-bubble technique. A bare Descemet membrane was achieved in all cases. Univariate analyses and multiple linear regression were used to investigate recipient-, donor-, and postoperative-related variables capable of influencing the postoperative quality of vision, including best spectacle-corrected visual acuity (BSCVA) and contrast sensitivity. The mean patient age was 27.7 ± 6.9 years, and the patients were followed for 24.6 ± 15.1 months postoperatively. The mean postoperative BSCVA was 0.17 ± 0.09 logMAR. Postoperative BSCVA ≥20/25 was achieved in 14 eyes (38.9%), whereas a BSCVA of 20/30, 20/40, or 20/50 was observed in 15 eyes (41.7%), 6 eyes (16.6%), and 1 eye (2.8%), respectively. Preoperative vitreous length was significantly associated with postoperative BSCVA (β = 0.02, P = .03). Donor-recipient interface reflectivity significantly influenced scotopic (β = -0.002, P = .04) and photopic (β = -0.003, P = .02) contrast sensitivity. The root mean square of tetrafoil was significantly negatively associated with scotopic (β = -0.25, P = .01) and photopic (β = -0.23, P = .04) contrast sensitivity. Recipient age, keratoconus severity, donor-related variables, recipient trephination size, and graft and recipient bed thickness were not significantly associated with postoperative visual acuity or contrast sensitivity. Large vitreous length, higher-order aberrations, and surgical interface haze may contribute to poor visual outcomes after big-bubble DALK in keratoconus. Copyright © 2016 Elsevier Inc. All rights reserved.
Shibeeb, O'Sam; Chidlow, Glyn; Han, Guoge; Wood, John P M; Casson, Robert J
2016-01-01
This study aims to evaluate the effect of subconjunctival glucose on the retinal ganglion cells (RGCs) in experimental retinal ischaemia and contrast sensitivity in humans with primary open-angle glaucoma (POAG). First, we measured the intravitreal concentration of glucose at various time points after a subconjunctival injection of 100 μl of 50% glucose to Sprague-Dawley rats. Next, treatment and control groups received 50% subconjunctival glucose and iso-osmotic (8%) saline, respectively, 1 h prior to a unilateral ischaemic retinal injury; 7 days later, the damage profiles were compared using RGC and axon counts. Subsequently, we conducted a double-blind, crossover, pilot clinical study in seven eyes of five pseudophakic subjects with severe POAG. Subjects received either 0.3 mL of 50% glucose subconjunctivally or iso-osmotic (8%) saline, then vice versa after a 2-3 week 'wash-out' period; change in contrast sensitivity from baseline was the primary outcome. Subconjunctival glucose preserved approximately 60% of Brn3a-positive RGCs in all retinal zones compared with an 80% loss in control retinas, and rescued approximately 40% of the axonal loss. In the human trial, the contrast sensitivity at 12 cycles/degree was 0.24 log units greater than baseline (95% confidence interval 0.12-0.36; P < 0.001). Subconjunctival glucose partially protects RGC somata and axons against an ischaemic insult and temporarily recovers contrast sensitivity in patients with severe POAG. Although an unlikely therapeutic strategy for POAG, the findings motivate further bioenergetic-based research in glaucoma and other optic nerve and retinal diseases, where energy failure may be part of the pathogenesis. © 2015 Royal Australian and New Zealand College of Ophthalmologists.
Nassiri, Nader; Sheibani, Kourosh; Azimi, Abbas; Khosravi, Farinaz Mahmoodi; Heravian, Javad; Yekta, Abasali; Moghaddam, Hadi Ostadi; Nassiri, Saman; Yasseri, Mehdi; Nassiri, Nariman
2015-10-01
To compare refractive outcomes, contrast sensitivity, higher-order aberrations (HOAs), and patient satisfaction after photorefractive keratectomy for correction of moderate myopia with two methods: tissue saving versus wavefront optimized. In this prospective, comparative study, 152 eyes (80 patients) with moderate myopia with and without astigmatism were randomly divided into two groups: the tissue-saving group (Technolas 217z Zyoptix laser; Bausch & Lomb, Rochester, NY) (76 eyes of 39 patients) or the wavefront-optimized group (WaveLight Allegretto Wave Eye-Q laser; Alcon Laboratories, Inc., Fort Worth, TX) (76 eyes of 41 patients). Preoperative and 3-month postoperative refractive outcomes, contrast sensitivity, HOAs, and patient satisfaction were compared between the two groups. The mean spherical equivalent was -4.50 ± 1.02 diopters. No statistically significant differences were detected between the groups in terms of uncorrected and corrected distance visual acuity and spherical equivalent preoperatively and 3 months postoperatively. No statistically significant differences were seen in the amount of preoperative to postoperative contrast sensitivity changes between the two groups in photopic and mesopic conditions. HOAs and Q factor increased in both groups postoperatively (P = .001), with the tissue-saving method causing more increases in HOAs (P = .007) and Q factor (P = .039). Patient satisfaction was comparable between both groups. Both platforms were effective in correcting moderate myopia with or without astigmatism. No difference in refractive outcome, contrast sensitivity changes, and patient satisfaction between the groups was observed. Postoperatively, the tissue-saving method caused a higher increase in HOAs and Q factor compared to the wavefront-optimized method, which could be due to larger optical zone sizes in the tissue-saving group. Copyright 2015, SLACK Incorporated.
Pina Rodrigues, Ana; Rebola, José; Jorge, Helena; Ribeiro, Maria José; Pereira, Marcelino; van Asselen, Marieke; Castelo-Branco, Miguel
2017-01-01
The specificity of visual channel impairment in dyslexia has been the subject of much controversy. The purpose of this study was to determine if a differential pattern of impairment can be verified between visual channels in children with developmental dyslexia, and in particular, if the pattern of deficits is more conspicuous in tasks where the magnocellular-dorsal system recruitment prevails. Additionally, we also aimed at investigating the association between visual perception thresholds and reading. In the present case-control study, we compared perception thresholds of 33 children diagnosed with developmental dyslexia and 34 controls in a speed discrimination task, an achromatic contrast sensitivity task, and a chromatic contrast sensitivity task. Moreover, we addressed the correlation between the different perception thresholds and reading performance, as assessed by means of a standardized reading test (accuracy and fluency). Group comparisons were performed by the Mann-Whitney U test, and Spearman's rho was used as a measure of correlation. Results showed that, when compared to controls, children with dyslexia were more impaired in the speed discrimination task, followed by the achromatic contrast sensitivity task, with no impairment in the chromatic contrast sensitivity task. These results are also consistent with the magnocellular theory since the impairment profile of children with dyslexia in the visual threshold tasks reflected the amount of magnocellular-dorsal stream involvement. Moreover, both speed and achromatic thresholds were significantly correlated with reading performance, in terms of accuracy and fluency. Notably, chromatic contrast sensitivity thresholds did not correlate with any of the reading measures. Our evidence stands in favor of a differential visual channel deficit in children with developmental dyslexia and contributes to the debate on the pathophysiology of reading impairments.
Qiu, Weiqiang; Liu, Ziyuan; Zhang, Zhihong; Ao, Mingxin; Li, Xuemin; Wang, Wei
2012-01-01
This study aimed to compare the effects of treatment with punctal plugs versus artificial tears on visual function and tear film stability for dry eye. A total of 56 consecutive eyes of 28 dry eye patients observed at our clinic from May to October in 2009 were divided into two groups. One group (32 eyes of 16 patients) was treated with artificial tears, and punctal plugs were used in the other group (24 eyes of 12 patients). A questionnaire was used in these patients before treatment and was repeated 2 weeks after treatment. Fluorescent staining for tear film break-up time (BUT), the Schirmer test I (STI), and contrast sensitivity was performed at the same time. The questionnaire indicated that all patients complained about the uncomfortable symptoms associated with dry eye. These symptoms were relieved after the application of artificial tears or punctal plugs, and there was no significant difference between these two groups. We found that the corneal fluorescent staining disappeared after treatment. The BUT was improved significantly after treatment in both groups, but the improvement was greater in patients who received punctal plugs than those that received artificial tears. There was no remarkable change in the STI in the artificial tears group, but a significant change was observed in the punctal plugs group. The contrast sensitivities were greatly improved in simulated daylight, night, and glare disability conditions after treatment with artificial tears and punctal plugs. However, the changes in contrast sensitivity did not significantly differ between groups. Both artificial tears and punctal plugs relieved dry eye symptoms, repaired corneal lesions, enhanced tear film stability, and improved contrast sensitivity. Punctal plugs could improve tear film stability and elongate the BUT better than artificial tears.
Rasta, Seyed Hossein; Partovi, Mahsa Eisazadeh; Seyedarabi, Hadi; Javadzadeh, Alireza
2015-01-01
To investigate the effect of preprocessing techniques including contrast enhancement and illumination correction on retinal image quality, a comparative study was carried out. We studied and implemented a few illumination correction and contrast enhancement techniques on color retinal images to find out the best technique for optimum image enhancement. To compare and choose the best illumination correction technique we analyzed the corrected red and green components of color retinal images statistically and visually. The two contrast enhancement techniques were analyzed using a vessel segmentation algorithm by calculating the sensitivity and specificity. The statistical evaluation of the illumination correction techniques were carried out by calculating the coefficients of variation. The dividing method using the median filter to estimate background illumination showed the lowest Coefficients of variations in the red component. The quotient and homomorphic filtering methods after the dividing method presented good results based on their low Coefficients of variations. The contrast limited adaptive histogram equalization increased the sensitivity of the vessel segmentation algorithm up to 5% in the same amount of accuracy. The contrast limited adaptive histogram equalization technique has a higher sensitivity than the polynomial transformation operator as a contrast enhancement technique for vessel segmentation. Three techniques including the dividing method using the median filter to estimate background, quotient based and homomorphic filtering were found as the effective illumination correction techniques based on a statistical evaluation. Applying the local contrast enhancement technique, such as CLAHE, for fundus images presented good potentials in enhancing the vasculature segmentation. PMID:25709940
Small fruit flies sacrifice temporal acuity to maintain contrast sensitivity.
Currea, John P; Smith, Joshua L; Theobald, Jamie C
2018-06-05
Holometabolous insects, like fruit flies, grow primarily during larval development. Scarce larval feeding is common in nature and generates smaller adults. Despite the importance of vision to flies, eye size scales proportionately with body size, and smaller eyes confer poorer vision due to smaller optics. Variable larval feeding, therefore, causes within-species differences in visual processing, which have gone largely unnoticed due to ad libitum feeding in the lab that results in generally large adults. Do smaller eyes have smaller ommatidial lenses, reducing sensitivity, or broader inter-ommatidial angles, reducing acuity? And to what extent might neural processes adapt to these optical challenges with temporal and spatial summation? To understand this in the fruit fly, we generated a distribution of body lengths (1.67-2.34 mm; n = 24) and eye lengths (0.33-0.44 mm; n = 24), resembling the distribution of wild-caught flies, by removing larvae from food during their third instar. We find smaller eyes (0.19 vs.0.07 mm 2 ) have substantially fewer (978 vs. 540, n = 45) and smaller ommatidia (222 vs. 121 μm 2 ;n = 45) separated by slightly wider inter-ommatidial angles (4.5 vs.5.5°; n = 34). This corresponds to a greater loss in contrast sensitivity (<50%) than spatial acuity (<20%). Using a flight arena and psychophysics paradigm, we find that smaller flies lose little spatial acuity (0.126 vs. 0.118CPD; n = 45), and recover contrast sensitivity (2.22 for both; n = 65) by sacrificing temporal acuity (26.3 vs. 10.8Hz; n = 112) at the neural level. Therefore, smaller flies sacrifice contrast sensitivity to maintain spatial acuity optically, but recover contrast sensitivity, almost completely, by sacrificing temporal acuity neurally. Copyright © 2018. Published by Elsevier Ltd.
Fillion, Myriam; Lemire, Mélanie; Philibert, Aline; Frenette, Benoît; Weiler, Hope Alberta; Deguire, Jason Robert; Guimarães, Jean Remy Davée; Larribe, Fabrice; Barbosa, Fernando; Mergler, Donna
2013-07-01
Visual functions are known to be sensitive to toxins such as mercury (Hg) and lead (Pb), while omega-3 fatty acids (FA) and selenium (Se) may be protective. In the Tapajós region of the Brazilian Amazon, all of these elements are present in the local diet. Examine how near visual contrast sensitivity and acquired color vision loss vary with biomarkers of toxic exposures (Hg and Pb) and the nutrients Se and omega-3 FA in riverside communities of the Tapajós. Complete visuo-ocular examinations were performed. Near visual contrast sensitivity and color vision were assessed in 228 participants (≥15 years) without diagnosed age-related cataracts or ocular pathologies and with near visual acuity refracted to at least 20/40. Biomarkers of Hg (hair), Pb (blood), Se (plasma), and the omega-3 FAs eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA) in plasma phospholipids were measured. Multiple linear regressions were used to examine the relations between visual outcomes and biomarkers, taking into account age, sex, drinking and smoking. Reduced contrast sensitivity at all spatial frequencies was associated with hair Hg, while %EPA, and to a lesser extent %EPA+DHA, were associated with better visual function. The intermediate spatial frequency of contrast sensitivity (12 cycles/degree) was negatively related to blood Pb and positively associated with plasma Se. Acquired color vision loss increased with hair Hg and decreased with plasma Se and %EPA. These findings suggest that the local diet of riverside communities of the Amazon contain toxic substances that can have deleterious effects on vision as well as nutrients that are beneficial for visual function. Since remediation at the source is a long process, a better knowledge of the nutrient content and health effects of traditional foods would be useful to minimize harmful effects of Hg and Pb exposure. Copyright © 2013 Elsevier Inc. All rights reserved.
[Visual function evaluation in human immunodeficiency virus carriers].
Solís-Castillo, A; Ramírez-Ponce, L A; Valdez-González, T; Seijo, E; Voorduin-Ramos, S; López-Star, E M
2011-04-01
To determine whether there are changes in the peripapillary nerve fibre layer, in colour vision, contrast sensitivity, dark adaptation and electroretinography changes in these patients who do not have infectious retinitis. We studied 52 patients without ocular pathology; the mean age was 35.88 years old. We observed less thickness in all quadrants, except the nasal. The colour vision was altered in 27.77% of the patients. The contrast sensitivity test showed high frequency alterations. There was no statistically significant difference in the electroretinography test or in dark adaptation. There are changes in the peripapillary nerve fibre layer thickness; also we found changes in colour vision, contrast sensitivity and a decreasing trend of the B wave in the electroreninogram. Copyright © 2010 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.
NASA Technical Reports Server (NTRS)
Carrasco, M.; Penpeci-Talgar, C.; Eckstein, M.
2000-01-01
This study is the first to report the benefits of spatial covert attention on contrast sensitivity in a wide range of spatial frequencies when a target alone was presented in the absence of a local post-mask. We used a peripheral precue (a small circle indicating the target location) to explore the effects of covert spatial attention on contrast sensitivity as assessed by orientation discrimination (Experiments 1-4), detection (Experiments 2 and 3) and localization (Experiment 3) tasks. In all four experiments the target (a Gabor patch ranging in spatial frequency from 0.5 to 10 cpd) was presented alone in one of eight possible locations equidistant from fixation. Contrast sensitivity was consistently higher for peripherally- than for neutrally-cued trials, even though we eliminated variables (distracters, global masks, local masks, and location uncertainty) that are known to contribute to an external noise reduction explanation of attention. When observers were presented with vertical and horizontal Gabor patches an external noise reduction signal detection model accounted for the cueing benefit in a discrimination task (Experiment 1). However, such a model could not account for this benefit when location uncertainty was reduced, either by: (a) Increasing overall performance level (Experiment 2); (b) increasing stimulus contrast to enable fine discriminations of slightly tilted suprathreshold stimuli (Experiment 3); and (c) presenting a local post-mask (Experiment 4). Given that attentional benefits occurred under conditions that exclude all variables predicted by the external noise reduction model, these results support the signal enhancement model of attention.
Barns, Gareth L; Thornton, Steven F; Wilson, Ryan D
2015-01-01
Heterogeneity in aquifer permeability, which creates paths of varying mass flux and spatially complex contaminant plumes, can complicate the interpretation of contaminant fate and transport in groundwater. Identifying the location of high mass flux paths is critical for the reliable estimation of solute transport parameters and design of groundwater remediation schemes. Dipole flow tracer tests (DFTTs) and push-pull tests (PPTs) are single well forced-gradient tests which have been used at field-scale to estimate aquifer hydraulic and transport properties. In this study, the potential for PPTs and DFTTs to resolve the location of layered high- and low-permeability layers in granular porous media was investigated with a pseudo 2-D bench-scale aquifer model. Finite element fate and transport modelling was also undertaken to identify appropriate set-ups for in situ tests to determine the type, magnitude, location and extent of such layered permeability contrasts at the field-scale. The characteristics of flow patterns created during experiments were evaluated using fluorescent dye imaging and compared with the breakthrough behaviour of an inorganic conservative tracer. The experimental results show that tracer breakthrough during PPTs is not sensitive to minor permeability contrasts for conditions where there is no hydraulic gradient. In contrast, DFTTs are sensitive to the type and location of permeability contrasts in the host media and could potentially be used to establish the presence and location of high or low mass flux paths. Numerical modelling shows that the tracer peak breakthrough time and concentration in a DFTT is sensitive to the magnitude of the permeability contrast (defined as the permeability of the layer over the permeability of the bulk media) between values of 0.01-20. DFTTs are shown to be more sensitive to deducing variations in the contrast, location and size of aquifer layered permeability contrasts when a shorter central packer is used. However, larger packer sizes are more likely to be practical for field-scale applications, with fewer tests required to characterise a given aquifer section. The sensitivity of DFTTs to identify layered permeability contrasts was not affected by test flow rate. Copyright © 2014 Elsevier B.V. All rights reserved.
Hallé, Pierre A; Ridouane, Rachid; Best, Catherine T
2016-01-01
In a discrimination experiment on several Tashlhiyt Berber singleton-geminate contrasts, we find that French listeners encounter substantial difficulty compared to native speakers. Native listeners of Tashlhiyt perform near ceiling level on all contrasts. French listeners perform better on final contrasts such as fit-fitt than initial contrasts such as bi-bbi or sir-ssir. That is, French listeners are more sensitive to silent closure duration in word-final voiceless stops than to either voiced murmur or frication duration of fully voiced stops or voiceless fricatives in word-initial position. We propose, tentatively, that native speakers of French, a language in which gemination is usually not considered to be phonemic, have not acquired quantity contrasts but yet exhibit a presumably universal sensitivity to rhythm, whereby listeners are able to perceive and compare the relative temporal distance between beats given by successive salient phonetic events such as a sequence of vowel nuclei.
Hallé, Pierre A.; Ridouane, Rachid; Best, Catherine T.
2016-01-01
In a discrimination experiment on several Tashlhiyt Berber singleton-geminate contrasts, we find that French listeners encounter substantial difficulty compared to native speakers. Native listeners of Tashlhiyt perform near ceiling level on all contrasts. French listeners perform better on final contrasts such as fit-fitt than initial contrasts such as bi-bbi or sir-ssir. That is, French listeners are more sensitive to silent closure duration in word-final voiceless stops than to either voiced murmur or frication duration of fully voiced stops or voiceless fricatives in word-initial position. We propose, tentatively, that native speakers of French, a language in which gemination is usually not considered to be phonemic, have not acquired quantity contrasts but yet exhibit a presumably universal sensitivity to rhythm, whereby listeners are able to perceive and compare the relative temporal distance between beats given by successive salient phonetic events such as a sequence of vowel nuclei. PMID:26973551
Operational Based Vision Assessment Cone Contrast Test: Description and Operation
2016-06-01
designed to detect abnormalities and characterize the contrast sensitivity of the color mechanisms of the human visual system. The OBVA CCT will...than 1, the individual is determined to have an abnormal L-M mechanism. The L-M sensitivity of mildly abnormal individuals (anomalous trichromats...response pads. This hardware is integrated with custom software that generates the stimuli, collects responses, and analyzes the results as outlined in
Gu, Hairong; Kim, Woojae; Hou, Fang; Lesmes, Luis Andres; Pitt, Mark A; Lu, Zhong-Lin; Myung, Jay I
2016-01-01
Measurement efficiency is of concern when a large number of observations are required to obtain reliable estimates for parametric models of vision. The standard entropy-based Bayesian adaptive testing procedures addressed the issue by selecting the most informative stimulus in sequential experimental trials. Noninformative, diffuse priors were commonly used in those tests. Hierarchical adaptive design optimization (HADO; Kim, Pitt, Lu, Steyvers, & Myung, 2014) further improves the efficiency of the standard Bayesian adaptive testing procedures by constructing an informative prior using data from observers who have already participated in the experiment. The present study represents an empirical validation of HADO in estimating the human contrast sensitivity function. The results show that HADO significantly improves the accuracy and precision of parameter estimates, and therefore requires many fewer observations to obtain reliable inference about contrast sensitivity, compared to the method of quick contrast sensitivity function (Lesmes, Lu, Baek, & Albright, 2010), which uses the standard Bayesian procedure. The improvement with HADO was maintained even when the prior was constructed from heterogeneous populations or a relatively small number of observers. These results of this case study support the conclusion that HADO can be used in Bayesian adaptive testing by replacing noninformative, diffuse priors with statistically justified informative priors without introducing unwanted bias.
Gu, Hairong; Kim, Woojae; Hou, Fang; Lesmes, Luis Andres; Pitt, Mark A.; Lu, Zhong-Lin; Myung, Jay I.
2016-01-01
Measurement efficiency is of concern when a large number of observations are required to obtain reliable estimates for parametric models of vision. The standard entropy-based Bayesian adaptive testing procedures addressed the issue by selecting the most informative stimulus in sequential experimental trials. Noninformative, diffuse priors were commonly used in those tests. Hierarchical adaptive design optimization (HADO; Kim, Pitt, Lu, Steyvers, & Myung, 2014) further improves the efficiency of the standard Bayesian adaptive testing procedures by constructing an informative prior using data from observers who have already participated in the experiment. The present study represents an empirical validation of HADO in estimating the human contrast sensitivity function. The results show that HADO significantly improves the accuracy and precision of parameter estimates, and therefore requires many fewer observations to obtain reliable inference about contrast sensitivity, compared to the method of quick contrast sensitivity function (Lesmes, Lu, Baek, & Albright, 2010), which uses the standard Bayesian procedure. The improvement with HADO was maintained even when the prior was constructed from heterogeneous populations or a relatively small number of observers. These results of this case study support the conclusion that HADO can be used in Bayesian adaptive testing by replacing noninformative, diffuse priors with statistically justified informative priors without introducing unwanted bias. PMID:27105061
Routine Use of Contrast Swallow After Total Gastrectomy and Esophagectomy: Is it Justified?
El-Sourani, Nader; Bruns, Helge; Troja, Achim; Raab, Hans-Rudolf; Antolovic, Dalibor
2017-01-01
After gastrectomy or esophagectomy, esophagogastrostomy and esophagojejunostomy are commonly used for reconstruction. Water-soluble contrast swallow is often used as a routine screening to exclude anastomotic leakage during the first postoperative week. In this retrospective study, the sensitivity and specificity of oral water-soluble contrast swallow for the detection of anastomotic leakage and its clinical symptoms were analysed. Records of 104 consecutive total gastrectomies and distal esophagectomies were analysed. In all cases, upper gastrointestinal contrast swallow with the use of a water-soluble contrast agent was performed on the 5 th postoperative day. Extravasation of the contrast agent was defined as anastomotic leakage. When anastomotic insufficiency was suspected but no extravasation was present, a computed tomography (CT) scan and upper endoscopy were performed. Oral contrast swallow detected 7 anastomotic leaks. Based on CT-scans and upper endoscopy, the true number of anastomotic leakage was 15. The findings of the oral contrast swallow were falsely positive in 4 and falsely negative in 12 patients, respectively. The sensitivity and specificity of the oral contrast swallow was 20% and 96%, respectively. Routine radiological contrast swallow following total gastrectomy or distal esophagectomy cannot be recommended. When symptoms of anastomotic leakage are present, a CT-scan and endoscopy are currently the methods of choice.
NASA Astrophysics Data System (ADS)
Vaysman, Ya I.; Surkov, AA; Surkova, Yu I.; Kychkin, AV
2017-06-01
The article is devoted to the use of renewable energy sources and the assessment of the feasibility of their use in the climatic conditions of the Western Urals. A simulation model that calculates the efficiency of a combined power installations (CPI) was (RES) developed. The CPI consists of the geothermal heat pump (GHP) and the vacuum solar collector (VCS) and is based on the research model. This model allows solving a wide range of problems in the field of energy and resource efficiency, and can be applied to other objects using RES. Based on the research recommendations for optimizing the management and the application of CPI were given. The optimization system will give a positive effect in the energy and resource consumption of low-rise residential buildings projects.
Lee, Chau Hung; Haaland, Benjamin; Earnest, Arul; Tan, Cher Heng
2013-09-01
To determine whether positive oral contrast agents improve accuracy of abdominopelvic CT compared with no, neutral or negative oral contrast agent. Literature was searched for studies evaluating the diagnostic performance of abdominopelvic CT with positive oral contrast agents against imaging with no, neutral or negative oral contrast agent. Meta-analysis reviewed studies correlating CT findings of blunt abdominal injury with positive and without oral contrast agents against surgical, autopsy or clinical outcome allowing derivation of pooled sensitivity and specificity. Systematic review was performed on studies with common design and reference standard. Thirty-two studies were divided into two groups. Group 1 comprised 15 studies comparing CT with positive and without oral contrast agents. Meta-analysis of five studies from group 1 provided no difference in sensitivity or specificity between CT with positive or without oral contrast agents. Group 2 comprised 17 studies comparing CT with positive and neutral or negative oral contrast agents. Systematic review of 12 studies from group 2 indicated that neutral or negative oral contrasts were as effective as positive oral contrast agents for bowel visualisation. There is no difference in accuracy between CT performed with positive oral contrast agents or with no, neutral or negative oral contrast agent. • There is no difference in the accuracy of CT with or without oral contrast agent. • There is no difference in the accuracy of CT with Gastrografin or water. • Omission of oral contrast, utilising neutral or negative oral contrast agent saves time, costs and decreases risk of aspiration.
Copper complexes as a source of redox active MRI contrast agents.
Dunbar, Lynsey; Sowden, Rebecca J; Trotter, Katherine D; Taylor, Michelle K; Smith, David; Kennedy, Alan R; Reglinski, John; Spickett, Corinne M
2015-10-01
The study reports an advance in designing copper-based redox sensing MRI contrast agents. Although the data demonstrate that copper(II) complexes are not able to compete with lanthanoids species in terms of contrast, the redox-dependent switch between diamagnetic copper(I) and paramagnetic copper(II) yields a novel redox-sensitive contrast moiety with potential for reversibility.
NASA Technical Reports Server (NTRS)
Klotzsch, Christof; Janben, Gerhard; Berlit, Peter
1994-01-01
Patent foramen ovale (PFO) is increasingly recognized in association with cryptogenic stroke. Using transesophageal echocardiography (TEE) and transcranial Doppler sonography with ultrasonic contrast medium contrast-(TCD), we evaluated the frequency of a PFO as the fundamental condition of paradoxical embolism in 111 patients after cerebral ischemia. There was a right-left shunt in 50 patients (45%) with TEE. In 31 of 40 patients with stroke of unknown etiology, a PFO was the only detectable finding associated with cerebral ischemia. Using TEE as he "gold standard," the sensitivity of contrast-TCD was 91.3%, specificity 93.8%, and the overall accuracy 92.8%. contrast-TCD failed to detect a right-left shunt in four patients, but there were four other patients with negative TEE and positive contrast-TCD. We conclude that contrast-TCD is a highly sensitive method for detecting a right-left shunt. Its advantages are low cost, its ability to detect single contrast-medium embolism, and control of the Valsalva maneuver by observing the decrease of cerebral blood flow. Evidence of PFO in cryptogenic stroke should prompt a search for a subclinical venous thrombosis as the embolic source.
Contrast-balanced binocular treatment in children with deprivation amblyopia.
Hamm, Lisa M; Chen, Zidong; Li, Jinrong; Dai, Shuan; Black, Joanna; Yuan, Junpeng; Yu, Minbin; Thompson, Benjamin
2017-11-28
Children with deprivation amblyopia due to childhood cataract have been excluded from much of the emerging research into amblyopia treatment. An investigation was conducted to determine whether contrast-balanced binocular treatment - a strategy currently being explored for children with anisometropic and strabismic amblyopia - may be effective in children with deprivation amblyopia. An unmasked, case-series design intended to assess proof of principle was employed. Eighteen children with deprivation amblyopia due to childhood cataracts (early bilateral n = 7, early unilateral n = 7, developmental n = 4), as well as 10 children with anisometropic (n = 8) or mixed anisometropic and strabismic amblyopia (n = 2) were prescribed one hour a day of treatment over a six-week period. Supervised treatment was available. Visual acuity, contrast sensitivity, global motion perception and interocular suppression were measured pre- and post-treatment. Visual acuity improvements occurred in the anisometropic/strabismic group (0.15 ± 0.05 logMAR, p = 0.014), but contrast sensitivity did not change. As a group, children with deprivation amblyopia had a smaller but statistically significant improvement in weaker eye visual acuity (0.09 ± 0.03 logMAR, p = 0.004), as well a significant improvement in weaker eye contrast sensitivity (p = 0.004). Subgroup analysis suggested that the children with early bilateral deprivation had the largest improvements, while children with early unilateral cataract did not improve. Interestingly, binocular contrast sensitivity also improved in children with early bilateral deprivation. Global motion perception improved for both subgroups with early visual deprivation, as well as children with anisometropic or mixed anisometropic/strabismic amblyopia. Interocular suppression improved for all subgroups except children with early unilateral deprivation. These data suggest that supervised contrast-balanced binocular treatment should be further investigated as a treatment option for children with deprivation amblyopia. However, for children with more severe deprivation amblyopia due to early unilateral cataracts, supplementary or alternative options should also be explored. © 2017 Optometry Australia.
The role of pulvinar in the transmission of information in the visual hierarchy.
Cortes, Nelson; van Vreeswijk, Carl
2012-01-01
VISUAL RECEPTIVE FIELD (RF) ATTRIBUTES IN VISUAL CORTEX OF PRIMATES HAVE BEEN EXPLAINED MAINLY FROM CORTICAL CONNECTIONS: visual RFs progress from simple to complex through cortico-cortical pathways from lower to higher levels in the visual hierarchy. This feedforward flow of information is paired with top-down processes through the feedback pathway. Although the hierarchical organization explains the spatial properties of RFs, is unclear how a non-linear transmission of activity through the visual hierarchy can yield smooth contrast response functions in all level of the hierarchy. Depending on the gain, non-linear transfer functions create either a bimodal response to contrast, or no contrast dependence of the response in the highest level of the hierarchy. One possible mechanism to regulate this transmission of visual contrast information from low to high level involves an external component that shortcuts the flow of information through the hierarchy. A candidate for this shortcut is the Pulvinar nucleus of the thalamus. To investigate representation of stimulus contrast a hierarchical model network of ten cortical areas is examined. In each level of the network, the activity from the previous layer is integrated and then non-linearly transmitted to the next level. The arrangement of interactions creates a gradient from simple to complex RFs of increasing size as one moves from lower to higher cortical levels. The visual input is modeled as a Gaussian random input, whose width codes for the contrast. This input is applied to the first area. The output activity ratio among different contrast values is analyzed for the last level to observe sensitivity to a contrast and contrast invariant tuning. For a purely cortical system, the output of the last area can be approximately contrast invariant, but the sensitivity to contrast is poor. To account for an alternative visual processing pathway, non-reciprocal connections from and to a parallel pulvinar like structure of nine areas is coupled to the system. Compared to the pure feedforward model, cortico-pulvino-cortical output presents much more sensitivity to contrast and has a similar level of contrast invariance of the tuning.
The Role of Pulvinar in the Transmission of Information in the Visual Hierarchy
Cortes, Nelson; van Vreeswijk, Carl
2012-01-01
Visual receptive field (RF) attributes in visual cortex of primates have been explained mainly from cortical connections: visual RFs progress from simple to complex through cortico-cortical pathways from lower to higher levels in the visual hierarchy. This feedforward flow of information is paired with top-down processes through the feedback pathway. Although the hierarchical organization explains the spatial properties of RFs, is unclear how a non-linear transmission of activity through the visual hierarchy can yield smooth contrast response functions in all level of the hierarchy. Depending on the gain, non-linear transfer functions create either a bimodal response to contrast, or no contrast dependence of the response in the highest level of the hierarchy. One possible mechanism to regulate this transmission of visual contrast information from low to high level involves an external component that shortcuts the flow of information through the hierarchy. A candidate for this shortcut is the Pulvinar nucleus of the thalamus. To investigate representation of stimulus contrast a hierarchical model network of ten cortical areas is examined. In each level of the network, the activity from the previous layer is integrated and then non-linearly transmitted to the next level. The arrangement of interactions creates a gradient from simple to complex RFs of increasing size as one moves from lower to higher cortical levels. The visual input is modeled as a Gaussian random input, whose width codes for the contrast. This input is applied to the first area. The output activity ratio among different contrast values is analyzed for the last level to observe sensitivity to a contrast and contrast invariant tuning. For a purely cortical system, the output of the last area can be approximately contrast invariant, but the sensitivity to contrast is poor. To account for an alternative visual processing pathway, non-reciprocal connections from and to a parallel pulvinar like structure of nine areas is coupled to the system. Compared to the pure feedforward model, cortico-pulvino-cortical output presents much more sensitivity to contrast and has a similar level of contrast invariance of the tuning. PMID:22654750
Studies of MRI relaxivities of gadolinium-labeled dendrons
NASA Astrophysics Data System (ADS)
Pan, Hongmu; Daniel, Marie-Christine
2011-05-01
In cancer detection, imaging techniques have a great importance in early diagnosis. The more sensitive the imaging technique and the earlier the tumor can be detected. Contrast agents have the capability to increase the sensitivity in imaging techniques such as magnetic resonance imaging (MRI). Until now, gadolinium-based contrast agents are mainly used for MRI, and show good enhancement. But improvement is needed for detection of smaller tumors at the earliest stage possible. The dendrons complexed with Gd(DOTA) were synthesized and evaluated as a new MRI contrast agent. The longitudinal and transverse relaxation effects were tested and compared with commercial drug Magnevist, Gd(DTPA).
Janisse, Kevyn; Doucet, Stéphanie M.
2017-01-01
Perceptual models of animal vision have greatly contributed to our understanding of animal-animal and plant-animal communication. The receptor-noise model of color contrasts has been central to this research as it quantifies the difference between two colors for any visual system of interest. However, if the properties of the visual system are unknown, assumptions regarding parameter values must be made, generally with unknown consequences. In this study, we conduct a sensitivity analysis of the receptor-noise model using avian visual system parameters to systematically investigate the influence of variation in light environment, photoreceptor sensitivities, photoreceptor densities, and light transmission properties of the ocular media and the oil droplets. We calculated the chromatic contrast of 15 plumage patches to quantify a dichromatism score for 70 species of Galliformes, a group of birds that display a wide range of sexual dimorphism. We found that the photoreceptor densities and the wavelength of maximum sensitivity of the short-wavelength-sensitive photoreceptor 1 (SWS1) can change dichromatism scores by 50% to 100%. In contrast, the light environment, transmission properties of the oil droplets, transmission properties of the ocular media, and the peak sensitivities of the cone photoreceptors had a smaller impact on the scores. By investigating the effect of varying two or more parameters simultaneously, we further demonstrate that improper parameterization could lead to differences between calculated and actual contrasts of more than 650%. Our findings demonstrate that improper parameterization of tetrachromatic visual models can have very large effects on measures of dichromatism scores, potentially leading to erroneous inferences. We urge more complete characterization of avian retinal properties and recommend that researchers either determine whether their species of interest possess an ultraviolet or near-ultraviolet sensitive SWS1 photoreceptor, or present models for both. PMID:28076391
Lacerda, Eliza Maria da Costa Brito; Lima, Monica Gomes; Rodrigues, Anderson Raiol; Teixeira, Cláudio Eduardo Correa; de Lima, Lauro José Barata; Ventura, Dora Fix; Silveira, Luiz Carlos de Lima
2012-01-01
The purpose of this paper was to evaluate achromatic and chromatic vision of workers chronically exposed to organic solvents through psychophysical methods. Thirty-one gas station workers (31.5 ± 8.4 years old) were evaluated. Psychophysical tests were achromatic tests (Snellen chart, spatial and temporal contrast sensitivity, and visual perimetry) and chromatic tests (Ishihara's test, color discrimination ellipses, and Farnsworth-Munsell 100 hue test—FM100). Spatial contrast sensitivities of exposed workers were lower than the control at spatial frequencies of 20 and 30 cpd whilst the temporal contrast sensitivity was preserved. Visual field losses were found in 10–30 degrees of eccentricity in the solvent exposed workers. The exposed workers group had higher error values of FM100 and wider color discrimination ellipses area compared to the controls. Workers occupationally exposed to organic solvents had abnormal visual functions, mainly color vision losses and visual field constriction. PMID:22220188
Towards an Analytical Age-Dependent Model of Contrast Sensitivity Functions for an Ageing Society
Joulan, Karine; Brémond, Roland
2015-01-01
The Contrast Sensitivity Function (CSF) describes how the visibility of a grating depends on the stimulus spatial frequency. Many published CSF data have demonstrated that contrast sensitivity declines with age. However, an age-dependent analytical model of the CSF is not available to date. In this paper, we propose such an analytical CSF model based on visual mechanisms, taking into account the age factor. To this end, we have extended an existing model from Barten (1999), taking into account the dependencies of this model's optical and physiological parameters on age. Age-dependent models of the cones and ganglion cells densities, the optical and neural MTF, and optical and neural noise are proposed, based on published data. The proposed age-dependent CSF is finally tested against available experimental data, with fair results. Such an age-dependent model may be beneficial when designing real-time age-dependent image coding and display applications. PMID:26078994
Matsuzawa, Fumihiko; Omoto, Kiyoka; Einama, Takahiro; Abe, Hironori; Suzuki, Takashi; Hamaguchi, Jun; Kaga, Terumi; Sato, Mami; Oomura, Masako; Takata, Yumiko; Fujibe, Ayako; Takeda, Chie; Tamura, Etsuya; Taketomi, Akinobu; Kyuno, Kenichi
2015-01-01
Breast cancer is the most common type of cancer in women. The 5-year survival rate in patients with breast cancer ranges from 74 to 82 %. Sentinel lymph node biopsy has become an alternative to axillary lymph node dissection for nodal staging. We evaluated the detection of the sentinel lymph node and metastasis of the lymph node using contrast enhanced ultrasonography with Sonazoid. Between December 2013 and May 2014, 32 patients with operable breast cancer were enrolled in this study. We evaluated the detection of axillary sentinel lymph nodes and the evaluation of axillary lymph nodes metastasis using contrast enhanced computed tomography, color Doppler ultrasonography and contrast enhanced ultrasonography with Sonazoid. All the sentinel lymph nodes were identified, and the sentinel lymph nodes detected by contrast enhanced ultrasonography with Sonazoid corresponded with those detected by computed tomography lymphography and indigo carmine method. The detection of metastasis based on contrast enhanced computed tomography were sensitivity 20.0 %, specificity 88.2 %, PPV 60.0 %, NPV 55.6 %, accuracy 56.3 %. Based on color Doppler ultrasonography, the results were sensitivity 36.4 %, specificity 95.2 %, PPV 80.0 %, NPV 74.1 %, accuracy 75.0 %. Based on contrast enhanced ultrasonography with Sonazoid, the results were sensitivity 81.8 %, specificity 95.2 %, PPV 90.0 %, NPV 90.9 %, accuracy 90.6 %. The results suggested that contrast enhanced ultrasonography with Sonazoid was the most accurate among the evaluations of these modalities. In the future, we believe that our method would take the place of conventional sentinel lymph node biopsy for an axillary staging method.
Schmitt, R; Christopoulos, G; Wagner, M; Krimmer, H; Fodor, S; van Schoonhoven, J; Prommersberger, K J
2011-02-01
The purpose of this prospective study is to assess the diagnostic value of intravenously applied contrast agent for diagnosing osteonecrosis of the proximal fragment in scaphoid nonunion, and to compare the imaging results with intraoperative findings. In 88 patients (7 women, 81 men) suffering from symptomatic scaphoid nonunion, preoperative MRI was performed (coronal PD-w FSE fs, sagittal-oblique T1-w SE nonenhanced and T1-w SE fs contrast-enhanced, sagittal T2*-w GRE). MRI interpretation was based on the intensity of contrast enhancement: 0 = none, 1 = focal, 2 = diffuse. Intraoperatively, the osseous viability was scored by means of bleeding points on the osteotomy site of the proximal scaphoid fragment: 0=absent, 1 = moderate, 2 = good. Intraoperatively, 17 necrotic, 29 compromised, and 42 normal proximal fragments were found. In nonenhanced MRI, bone viability was judged necrotic in 1 patient, compromised in 20 patients, and unaffected in 67 patients. Contrast-enhanced MRI revealed 14 necrotic, 21 compromised, and 53 normal proximal fragments. Judging surgical findings as the standard of reference, statistical analysis for nonenhanced MRI was: sensitivity 6.3%, specificity 100%, positive PV 100%, negative PV 82.6%, and accuracy 82.9%; statistics for contrast-enhanced MRI was: sensitivity 76.5%, specificity 98.6%, positive PV 92.9%, negative PV 94.6%, and accuracy 94.3%. Sensitivity for detecting avascular proximal fragments was significantly better (p<0.001) in contrast-enhanced MRI in comparison to nonenhanced MRI. Viability of the proximal fragment in scaphoid nonunion can be significantly better assessed with the use of contrast-enhanced MRI as compared to nonenhanced MRI. Bone marrow edema is an inferior indicator of osteonecrosis. Application of intravenous gadolinium is recommended for imaging scaphoid nonunion. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Lee-Felker, Stephanie A; Tekchandani, Leena; Thomas, Mariam; Gupta, Esha; Andrews-Tang, Denise; Roth, Antoinette; Sayre, James; Rahbar, Guita
2017-11-01
Purpose To compare the diagnostic performances of contrast material-enhanced spectral mammography and breast magnetic resonance (MR) imaging in the detection of index and secondary cancers in women with newly diagnosed breast cancer by using histologic or imaging follow-up as the standard of reference. Materials and Methods This institutional review board-approved, HIPAA-compliant, retrospective study included 52 women who underwent breast MR imaging and contrast-enhanced spectral mammography for newly diagnosed unilateral breast cancer between March 2014 and October 2015. Of those 52 patients, 46 were referred for contrast-enhanced spectral mammography and targeted ultrasonography because they had additional suspicious lesions at MR imaging. In six of the 52 patients, breast cancer had been diagnosed at an outside institution. These patients were referred for contrast-enhanced spectral mammography and targeted US as part of diagnostic imaging. Images from contrast-enhanced spectral mammography were analyzed by two fellowship-trained breast imagers with 2.5 years of experience with contrast-enhanced spectral mammography. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value were calculated for both imaging modalities and compared by using the Bennett statistic. Results Fifty-two women with 120 breast lesions were included for analysis (mean age, 50 years; range, 29-73 years). Contrast-enhanced spectral mammography had similar sensitivity to MR imaging (94% [66 of 70 lesions] vs 99% [69 of 70 lesions]), a significantly higher PPV than MR imaging (93% [66 of 71 lesions] vs 60% [69 of 115 lesions]), and fewer false-positive findings than MR imaging (five vs 45) (P < .001 for all results). In addition, contrast-enhanced spectral mammography depicted 11 of the 11 secondary cancers (100%) and MR imaging depicted 10 (91%). Conclusion Contrast-enhanced spectral mammography is potentially as sensitive as MR imaging in the evaluation of extent of disease in newly diagnosed breast cancer, with a higher PPV. © RSNA, 2017.
Temporal dynamics of contrast gain in single cells of the cat striate cortex.
Bonds, A B
1991-03-01
The response amplitude of cat striate cortical cells is usually reduced after exposure to high-contrast stimuli. The temporal characteristics and contrast sensitivity of this phenomenon were explored by stimulating cortical cells with drifting gratings in which contrast sequentially incremented and decremented in stepwise fashion over time. All responses showed a clear hysteresis, in which contrast gain dropped on average 0.36 log unit and then returned to baseline values within 60 s. Noticeable gain adjustments were seen in as little as 3 s and with peak contrasts as low as 3%. Contrast adaptation was absent in responses from LGN cells. Adaptation was found to depend on temporal frequency of stimulation, with greater and more rapid adaptation at higher temporal frequencies. Two different tests showed that the mechanism controlling response reduction was influenced primarily by stimulus contrast rather than response amplitude. These results support the existence of a rapid and sensitive cortically based system that normalizes the output of cortical cells as a function of local mean contrast. Control of the adaptation appears to arise at least in part across a population of cells, which is consistent with the idea that the gain control serves to limit the information converging from many cells onto subsequent processing areas.
Rabin, Jeff C; Karunathilake, Nirmani; Patrizi, Korey
2018-04-26
Consumption of dark chocolate can improve blood flow, mood, and cognition in the short term, but little is known about the possible effects of dark chocolate on visual performance. To compare the short-term effects of consumption of dark chocolate with those of milk chocolate on visual acuity and large- and small-letter contrast sensitivity. A randomized, single-masked crossover design was used to assess short-term visual performance after consumption of a dark or a milk chocolate bar. Thirty participants without pathologic eye disease each consumed dark and milk chocolate in separate sessions, and within-participant paired comparisons were used to assess outcomes. Testing was conducted at the Rosenberg School of Optometry from June 25 to August 15, 2017. Visual acuity (in logMAR units) and large- and small-letter contrast sensitivity (in the log of the inverse of the minimum detectable contrast [logCS units]) were measured 1.75 hours after consumption of dark and milk chocolate bars. Among the 30 participants (9 men and 21 women; mean [SD] age, 26 [5] years), small-letter contrast sensitivity was significantly higher after consumption of dark chocolate (mean [SE], 1.45 [0.04] logCS) vs milk chocolate (mean [SE], 1.30 [0.05] logCS; mean improvement, 0.15 logCS [95% CI, 0.08-0.22 logCS]; P < .001). Large-letter contrast sensitivity was slightly higher after consumption of dark chocolate (mean [SE], 2.05 [0.02] logCS) vs milk chocolate (mean [SE], 2.00 [0.02] logCS; mean improvement, 0.05 logCS [95% CI, 0.00-0.10 logCS]; P = .07). Visual acuity improved slightly after consumption of dark chocolate (mean [SE], -0.22 [0.01] logMAR; visual acuity, approximately 20/12) and milk chocolate (mean [SE], -0.18 [0.01] logMAR; visual acuity, approximately 20/15; mean improvement, 0.04 logMAR [95% CI, 0.02-0.06 logMAR]; P = .05). Composite scores combining results from all tests showed significant improvement after consumption of dark compared with milk chocolate (mean improvement, 0.20 log U [95% CI, 0.10-0.30 log U]; P < .001). Contrast sensitivity and visual acuity were significantly higher 2 hours after consumption of a dark chocolate bar compared with a milk chocolate bar, but the duration of these effects and their influence in real-world performance await further testing. clinicaltrials.gov Identifier: NCT03326934.
NASA Astrophysics Data System (ADS)
Glickman, Randolph D.; Harrison, Joseph M.; Zwick, Harry; Longbotham, Harold G.; Ballentine, Charles S.; Pierce, Bennie
1996-04-01
Although visual function following retinal laser injuries has traditionally been assessed by measuring visual acuity, this measure only indicates the highest spatial frequency resolvable under high-contrast viewing conditions. Another visual psychophysical parameter is contrast sensitivity (CS), which measures the minimum contrast required for detection of targets over a range of spatial frequencies, and may evaluate visual mechanisms that do not directly subserve acuity. We used the visual evoked potential (VEP) to measure CS in a population of normal subjects and in patients with ophthalmic conditions affecting retinal function, including one patient with a laser injury in the macula. In this patient, the acuity had recovered from
Anastomotic leakage after colorectal surgery: diagnostic accuracy of CT.
Kauv, Paul; Benadjaoud, Samir; Curis, Emmanuel; Boulay-Coletta, Isabelle; Loriau, Jerome; Zins, Marc
2015-12-01
To evaluate the diagnostic accuracy of CT in postoperative colorectal anastomotic leakage (AL). Two independent blinded radiologists reviewed 153 CTs performed for suspected AL within 60 days after surgery in 131 consecutive patients, with (n = 58) or without (n = 95) retrograde contrast enema (RCE). Results were compared to original interpretations. The reference standard was reoperation or consensus (a radiologist and a surgeon) regarding clinical, laboratory, radiological, and follow-up data after medical treatment. AL was confirmed in 34/131 patients. For the two reviewers and original interpretation, sensitivity of CT was 82 %, 87 %, and 71 %, respectively; specificity was 84 %, 84 %, and 92 %. RCE significantly increased the positive predictive value (from 40 % to 88 %, P = 0.0009; 41 % to 92 %, P = 0.0016; and 40 % to 100 %, P = 0.0006). Contrast extravasation was the most sensitive (reviewers, 83 % and 83 %) and specific (97 % and 97 %) sign and was significantly associated with AL by univariate analysis (P < 0.0001 and P < 0.0001). By multivariate analysis with recursive partitioning, CT with RCE was accurate to confirm or rule out AL with contrast extravasation. CT with RCE is accurate for diagnosing postoperative colorectal AL. Contrast extravasation is the most reliable sign. RCE should be performed during CT for suspected AL. • CT accurately diagnosed clinically suspected colorectal AL and showed good interobserver agreement • Contrast extravasation was the most sensitive and specific CT sign • Retrograde contrast enema during CT improved positive predictive value • Retrograde contrast enema decreased false-negative or indeterminate original CT interpretations.
Desai, Vishal; Cox, Mougnyan; Deshmukh, Sandeep; Roth, Christopher G
2018-04-20
In the emergency setting, flank pain commonly leads to a noncontrast CT despite a significant percentage of patients having alternative diagnoses, often difficult to characterize without contrast. We investigated the combined utility of urinalysis and history of urolithiasis in identifying patients who are unlikely to have urolithiasis and may benefit from a contrast-enhanced study. Retrospective review of 350 patients from May 2013 to May 2016 was performed for patients in the emergency department with renal colic that underwent noncontrast CT and urinalysis testing. Urolithiasis was present in 282 of the 350 patients reviewed (81%), of which 175 (62%) had an obstructing calculus. RBC-positive urinalysis was present in 231 patients with calculi on CT (sensitivity 82%). Patient history of urolithiasis plus urinalysis had a sensitivity of 94% for detecting calculi. Thirty-five patients (10%) had alternative diagnoses, 33 of which were in patients without obstructing calculi. Sixty-seven patients underwent noncontrast CT despite no history of urolithiasis and a negative urinalysis, 10 of which (15%) had alternative diagnoses. Only three cases in this subset (4%) had nonobstructing 1-2-mm calculi, potentially missed with contrast. In this subset, the projected proportion of optimally characterized cases with intravenous contrast is 96%, compared to 85% without contrast (p = .03). Given the high combined sensitivity of urinalysis and patient history (94%), this simple analysis can confidently direct clinicians to a contrast-enhanced CT in "rule-out" cases of flank pain in patients with a negative history and negative urinalysis, particularly given that 15% of these patients had alternative diagnoses.
Early Sensitivity to Discourse-Level Anomalies: Evidence from Self-Paced Reading
ERIC Educational Resources Information Center
Stewart, Andrew J.; Kidd, Evan; Haigh, Matthew
2009-01-01
Two word-by-word, self-paced reading experiments investigated the speed with which readers were sensitive to discourse-level anomalies. An account arguing for delayed sensitivity (Guzman & Klin, 2000) was contrasted with one allowing for rapid sensitivity (Myers & O'Brien, 1998). Anomalies related to spatial information (Experiment 1) and…
Visual motion modulates pattern sensitivity ahead, behind, and beside motion
Arnold, Derek H.; Marinovic, Welber; Whitney, David
2014-01-01
Retinal motion can modulate visual sensitivity. For instance, low contrast drifting waveforms (targets) can be easier to detect when abutting the leading edges of movement in adjacent high contrast waveforms (inducers), rather than the trailing edges. This target-inducer interaction is contingent on the adjacent waveforms being consistent with one another – in-phase as opposed to out-of-phase. It has been suggested that this happens because there is a perceptually explicit predictive signal at leading edges of motion that summates with low contrast physical input – a ‘predictive summation’. Another possible explanation is a phase sensitive ‘spatial summation’, a summation of physical inputs spread across the retina (not predictive signals). This should be non-selective in terms of position – it should be evident at leading, adjacent, and at trailing edges of motion. To tease these possibilities apart, we examined target sensitivity at leading, adjacent, and trailing edges of motion. We also examined target sensitivity adjacent to flicker, and for a stimulus that is less susceptible to spatial summation, as it sums to grey across a small retinal expanse. We found evidence for spatial summation in all but the last condition. Finally, we examined sensitivity to an absence of signal at leading and trailing edges of motion, finding greater sensitivity at leading edges. These results are inconsistent with the existence of a perceptually explicit predictive signal in advance of drifting waveforms. Instead, we suggest that phase-contingent target-inducer modulations of sensitivity are explicable in terms of a directionally modulated spatial summation. PMID:24699250
Koefoed, Vilhelm F; Baste, Valborg; Roumes, Corinne; Høvding, Gunnar
2015-03-01
This study reports contrast sensitivity (CS) reference values obtained by two different test methods in a strictly selected population of healthy, young adults with normal uncorrected visual acuity. Based on these results, the index of contrast sensitivity (ICS) is calculated, aiming to establish ICS reference values for this population and to evaluate the possible usefulness of ICS as a tool to compare the degree of agreement between different CS test methods. Military recruits with best eye uncorrected visual acuity 0.00 LogMAR or better, normal colour vision and age 18-25 years were included in a study to record contrast sensitivity using Optec 6500 (FACT) at spatial frequencies of 1.5, 3, 6, 12 and 18 cpd in photopic and mesopic light and CSV-1000E at spatial frequencies of 3, 6, 12 and 18 cpd in photopic light. Index of contrast sensitivity was calculated based on data from the three tests, and the Bland-Altman technique was used to analyse the agreement between ICS obtained by the different test methods. A total of 180 recruits were included. Contrast sensitivity frequency data for all tests were highly skewed with a marked ceiling effect for the photopic tests. The median ICS for Optec 6500 at 85 cd/m2 was -0.15 (95% percentile 0.45), compared with -0.00 (95% percentile 1.62) for Optec at 3 cd/m2 and 0.30 (95% percentile 1.20) FOR CSV-1000E. The mean difference between ICSFACT 85 and ICSCSV was -0.43 (95% CI -0.56 to -0.30, p<0.00) with limits of agreement (LoA) within -2.10 and 1.22. The regression line on the difference of average was near to zero (R2=0.03). The results provide reference CS and ICS values in a young, adult population with normal visual acuity. The agreement between the photopic tests indicated that they may be used interchangeably. There was little agreement between the mesopic and photopic tests. The mesopic test seemed best suited to differentiate between candidates and may therefore possibly be useful for medical selection purposes. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Coherent Anti-Stokes Raman Scattering Spectroscopy of Single Molecules in Solution
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sunney Xie, Wei Min, Chris Freudiger, Sijia Lu
2012-01-18
During this funding period, we have developed two breakthrough techniques. The first is stimulated Raman scattering microscopy, providing label-free chemical contrast for chemical and biomedical imaging based on vibrational spectroscopy. Spontaneous Raman microscopy provides specific vibrational signatures of chemical bonds, but is often hindered by low sensitivity. We developed a three-dimensional multiphoton vibrational imaging technique based on stimulated Raman scattering (SRS). The sensitivity of SRS imaging is significantly greater than that of spontaneous Raman microscopy, which is achieved by implementing high-frequency (megahertz) phase-sensitive detection. SRS microscopy has a major advantage over previous coherent Raman techniques in that it offers background-freemore » and readily interpretable chemical contrast. We demonstrated a variety of biomedical applications, such as differentiating distributions of omega-3 fatty acids and saturated lipids in living cells, imaging of brain and skin tissues based on intrinsic lipid contrast, and monitoring drug delivery through the epidermis. This technology offers exciting prospect for medical imaging. The second technology we developed is stimulated emission microscopy. Many chromophores, such as haemoglobin and cytochromes, absorb but have undetectable fluorescence because the spontaneous emission is dominated by their fast non-radiative decay. Yet the detection of their absorption is difficult under a microscope. We use stimulated emission, which competes effectively with the nonradiative decay, to make the chromophores detectable, as a new contrast mechanism for optical microscopy. We demonstrate a variety of applications of stimulated emission microscopy, such as visualizing chromoproteins, non-fluorescent variants of the green fluorescent protein, monitoring lacZ gene expression with a chromogenic reporter, mapping transdermal drug distribu- tions without histological sectioning, and label-free microvascular imaging based on endogenous contrast of haemoglobin. For all these applications, sensitivity is orders of magnitude higher than for spontaneous emission or absorption contrast, permitting nonfluorescent reporters for molecular imaging. Although we did not accomplish the original goal of detecting single-molecule by CARS, our quest for high sensitivity of nonlinear optical microscopy paid off in providing the two brand new enabling technologies. Both techniques were greatly benefited from the use of high frequency modulation for microscopy, which led to orders of magnitude increase in sensitivity. Extensive efforts have been made on optics and electronics to accomplish these breakthroughs.« less
Targeted Molecular Imaging of Cancer Cells Using MS2-Based 129 Xe NMR
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jeong, Keunhong; Netirojjanakul, Chawita; Munch, Henrik K.
Targeted, selective, and highly sensitive 129Xe NMR nanoscale biosensors have been synthesized using a spherical MS2 viral capsid, Cryptophane A molecules, and DNA aptamers. The biosensors showed strong binding specificity toward targeted lymphoma cells (Ramos line). Hyperpolarized 129Xe NMR signal contrast and hyper-CEST 129Xe MRI image contrast indicated its promise as highly sensitive hyperpolarized 129Xe NMR nanoscale biosensor for future applications in cancer detection in vivo.
Optical transfer function in corneal topography for clinical contrast sensitivity analysis
NASA Astrophysics Data System (ADS)
Bende, Thomas; Jean, Benedikt J.; Oltrup, Theo
2000-06-01
Customized ablation aiming to optimize visual acuity in refractive surgery requires objective data on corneal surface, like the contrast sensitivity. Fast ray tracing, using the high resolution 3-D elevation data in conjunction with Snell's law describe the diffraction of the incident rays and the resulting image on a 'virtual retina.' A retroprojection leads to a 'surface quality map.' For objective contrast sensitivity measurement a sinus (or cos) wave of different frequencies is used for a calculated projection in analogy to the clinical contrast sensitivity charts. The projection on the individual cornea surface is analyzed for the Modular Transfer Function (MTF) and the Phase Shift Function (PSF) as a function of frequencies. PSF, not yet clinically used, is a parameter to determine even minimal corneal tilt. The resulting corneal aberration map (CAM) as described here and applied to a 4.5 D PRK (OZD equals 6.5 mm) reveals that the area of minimal aberration measures only 4.2 mm. The CAM can likewise be used to describe the 'quality' of a laser system's ablation pattern based upon the area of minimal optical aberrations. The CAM only describes surface aberration with high resolution, an advantage over wave front sensing which measures all accumulated optical aberrations including the changing ones of the lens during accommodation and the transient ones due to lens aging and early cataract formation.
NASA Astrophysics Data System (ADS)
Song, Lipei; Wang, Xueyan; Zhang, Ru; Zhang, Kuanshou; Zhou, Zhen; Elson, Daniel S.
2018-07-01
The fluctuation of contrast caused by statistical noise degenerates the temporal/spatial resolution of laser speckle contrast imaging (LSCI) and limits the maximum speed when imaging. In this study, we investigated the application of the anisotropic diffusion filter (ADF) to temporal LSCI and found that the edge magnitude parameter of the ADF can be determined by the mean of the contrast image. Because the edge magnitude parameter is usually denoted as K, we term this the K-constant ADF (KC-ADF) and show that temporal sensitivity is improved when imaging because of the enhanced signal-to-noise ratio when using the KC-ADF in small-animal experiments. The cardiac cycle of a rat as high as 390 bpm can be imaged with an industrial camera.
Sensory Contributions to Impaired Emotion Processing in Schizophrenia
Butler, Pamela D.; Abeles, Ilana Y.; Weiskopf, Nicole G.; Tambini, Arielle; Jalbrzikowski, Maria; Legatt, Michael E.; Zemon, Vance; Loughead, James; Gur, Ruben C.; Javitt, Daniel C.
2009-01-01
Both emotion and visual processing deficits are documented in schizophrenia, and preferential magnocellular visual pathway dysfunction has been reported in several studies. This study examined the contribution to emotion-processing deficits of magnocellular and parvocellular visual pathway function, based on stimulus properties and shape of contrast response functions. Experiment 1 examined the relationship between contrast sensitivity to magnocellular- and parvocellular-biased stimuli and emotion recognition using the Penn Emotion Recognition (ER-40) and Emotion Differentiation (EMODIFF) tests. Experiment 2 altered the contrast levels of the faces themselves to determine whether emotion detection curves would show a pattern characteristic of magnocellular neurons and whether patients would show a deficit in performance related to early sensory processing stages. Results for experiment 1 showed that patients had impaired emotion processing and a preferential magnocellular deficit on the contrast sensitivity task. Greater deficits in ER-40 and EMODIFF performance correlated with impaired contrast sensitivity to the magnocellular-biased condition, which remained significant for the EMODIFF task even when nonspecific correlations due to group were considered in a step-wise regression. Experiment 2 showed contrast response functions indicative of magnocellular processing for both groups, with patients showing impaired performance. Impaired emotion identification on this task was also correlated with magnocellular-biased visual sensory processing dysfunction. These results provide evidence for a contribution of impaired early-stage visual processing in emotion recognition deficits in schizophrenia and suggest that a bottom-up approach to remediation may be effective. PMID:19793797
Sensory contributions to impaired emotion processing in schizophrenia.
Butler, Pamela D; Abeles, Ilana Y; Weiskopf, Nicole G; Tambini, Arielle; Jalbrzikowski, Maria; Legatt, Michael E; Zemon, Vance; Loughead, James; Gur, Ruben C; Javitt, Daniel C
2009-11-01
Both emotion and visual processing deficits are documented in schizophrenia, and preferential magnocellular visual pathway dysfunction has been reported in several studies. This study examined the contribution to emotion-processing deficits of magnocellular and parvocellular visual pathway function, based on stimulus properties and shape of contrast response functions. Experiment 1 examined the relationship between contrast sensitivity to magnocellular- and parvocellular-biased stimuli and emotion recognition using the Penn Emotion Recognition (ER-40) and Emotion Differentiation (EMODIFF) tests. Experiment 2 altered the contrast levels of the faces themselves to determine whether emotion detection curves would show a pattern characteristic of magnocellular neurons and whether patients would show a deficit in performance related to early sensory processing stages. Results for experiment 1 showed that patients had impaired emotion processing and a preferential magnocellular deficit on the contrast sensitivity task. Greater deficits in ER-40 and EMODIFF performance correlated with impaired contrast sensitivity to the magnocellular-biased condition, which remained significant for the EMODIFF task even when nonspecific correlations due to group were considered in a step-wise regression. Experiment 2 showed contrast response functions indicative of magnocellular processing for both groups, with patients showing impaired performance. Impaired emotion identification on this task was also correlated with magnocellular-biased visual sensory processing dysfunction. These results provide evidence for a contribution of impaired early-stage visual processing in emotion recognition deficits in schizophrenia and suggest that a bottom-up approach to remediation may be effective.
Zeng, Meng-Su; Ye, Hui-Yi; Guo, Liang; Peng, Wei-Jun; Lu, Jian-Ping; Teng, Gao-Jun; Huan, Yi; Li, Ping; Xu, Jian-Rong; Liang, Chang-Hong; Breuer, Josy
2013-12-01
Contrast agents help to improve visibility in magnetic resonance (MR) imaging. However, owing to the large interstitial spaces of the liver, there is a reduction in the natural contrast gradient between lesions and healthy tissue. This study was undertaken to evaluate the efficacy and safety of the liver-specific MR imaging contrast agent gadoxetate disodium (Gd-EOB-DTPA) in Chinese patients. This was a single-arm, open-label, multicenter study in patients with known or suspected focal liver lesions referred for contrast-enhanced MR imaging. MR imaging was performed in 234 patients before and after a single intravenous bolus of Gd-EOB-DTPA (0.025 mmol/kg body weight). Images were evaluated by clinical study investigators and three independent, blinded radiologists. The primary efficacy endpoint was sensitivity in lesion detection. Gd-EOB-DTPA improved sensitivity in lesion detection by 9.46% compared with pre-contrast imaging for the average of the three blinded readers (94.78% vs 85.32% for Gd-EOB-DTPA vs pre-contrast, respectively). Improvements in detection were more pronounced in lesions less than 1 cm. Gd-EOB-DTPA improved diagnostic accuracy in lesion classification. This open-label study demonstrated that Gd-EOB-DTPA improves diagnostic sensitivity in liver lesions, particularly in those smaller than 1 cm. Gd-EOB-DTPA also significantly improves the diagnostic accuracy in lesion classification, and furthermore, Gd-EOB-DTPA is safe in Chinese patients with liver lesions.
Nielsen, Flemming K; Egund, Niels; Jørgensen, Anette; Peters, David A; Jurik, Anne Grethe
2016-11-16
Bone marrow lesions (BMLs) in knee osteoarthritis (OA) can be assessed using fluid sensitive and contrast enhanced sequences. The association between BMLs and symptoms has been investigated in several studies but only using fluid sensitive sequences. Our aims were to assess BMLs by contrast enhanced MRI sequences in comparison with a fluid sensitive STIR sequence using two different segmentation methods and to analyze the association between the MR findings and disability and pain. Twenty-two patients (mean age 61 years, range 41-79 years) with medial femoro-tibial knee OA obtained MRI and filled out a WOMAC questionnaire at baseline and follow-up (median interval of 334 days). STIR, dynamic contrast enhanced-MRI (DCE-MRI) and fat saturated T1 post-contrast (T1 CE FS) MRI sequences were obtained. All STIR and T1 CE FS sequences were assessed independently by two readers for STIR-BMLs and contrast enhancing areas of BMLs (CEA-BMLs) using manual segmentation and computer assisted segmentation, and the measurements were compared. DCE-MRIs were assessed for the relative distribution of voxels with an inflammatory enhancement pattern, N voxel , in the bone marrow. All findings were compared to WOMAC scores, including pain and overall symptoms, and changes from baseline to follow-up were analyzed. The average volume of CEA-BML was smaller than the STIR-BML volume by manual segmentation. The opposite was found for computer assisted segmentation where the average CEA-BML volume was larger than the STIR-BML volume. The contradictory finding by computer assisted segmentation was partly caused by a number of outliers with an apparent generally increased signal intensity in the anterior parts of the femoral condyle and tibial plateau causing an overestimation of the CEA-BML volume. Both CEA-BML, STIR-BML and N voxel were significantly correlated with symptoms and to a similar degree. A significant reduction in total WOMAC score was seen at follow-up, but no significant changes were observed for either CEA-BML, STIR-BML or N voxel . Neither the degree nor the volume of contrast enhancement in BMLs seems to add any clinical information compared to BMLs visualized by fluid sensitive sequences. Manual segmentation may be needed to obtain valid CEA-BML measurements.
High-Contrast Imaging of Epsilon Eridani with Ground-Based Instruments
NASA Technical Reports Server (NTRS)
Mizuki, T.; Yamada, T.; Carson, J. C.; Kuzuhara, M.; Nakagawa, T.; Nishikawa, J.; Sitko, M. L.; Kudo, T.; Kusakabe, N.; Hashimoto, J.;
2016-01-01
Epsilon Eridani is one of the nearest solar-type stars. Its proximity and relatively young age allow high-contrast imaging observations to achieve sensitivities to planets at narrow separations down to an inner radius of approximately 5 AU. Previous observational studies of the system report a dust disk with asymmetric morphology as well as a giant planet with large orbital eccentricity, which may require another massive companion to induce the peculiar morphology and to enhance the large orbital eccentricity. In this paper, we report results from deep high-contrast imaging observations to detect the previously reported planet and search for other unseen less massive companions with Subaru/HiCIAO, Gemini-South/NICI, and VLT/NACO. No positive detection was made, but high-contrast measurements with the CH4S narrow-band filter of HiCIAO achieved sensitivities at 14.7 mag differential magnitude level, at an angular separation of 1.0''. In terms of planetary mass, as determined by cooling evolutionary models, the highest sensitivities were achieved by the Lp broad-band filter of NACO, resulting in sensitivities corresponding to 1.8, 2.8, and 4.5 M(sub jup) at the projected separation of 3 AU, if 200, 400, and 800 Myr is assumed for the age of the system, respectively. We also discuss origins of the dust disk from the detection sensitivity in the planetary mass and find that a less massive eccentric planet is preferred for disk stirring, which is consistent with the orbital parameters of epsilon Eri b claimed from the previous long-term radial velocity monitoring.
The role of cone-beam breast-CT for breast cancer detection relative to breast density.
Wienbeck, Susanne; Uhlig, Johannes; Luftner-Nagel, Susanne; Zapf, Antonia; Surov, Alexey; von Fintel, Eva; Stahnke, Vera; Lotz, Joachim; Fischer, Uwe
2017-12-01
To evaluate the impact of breast density on the diagnostic accuracy of non-contrast cone-beam breast computed tomography (CBBCT) in comparison to mammography for the detection of breast masses. A retrospective study was conducted from August 2015 to July 2016. Fifty-nine patients (65 breasts, 112 lesions) with BI-RADS, 5th edition 4 or 5 assessment in mammography and/or ultrasound of the breast received an additional non-contrast CBBCT. Independent double blind reading by two radiologists was performed for mammography and CBBCT imaging. Sensitivity, specificity and AUC were compared between the modalities. Breast lesions were histologically examined in 85 of 112 lesions (76%). The overall sensitivity for CBBCT (reader 1: 91%, reader 2: 88%) was higher than in mammography (both: 68%, p<0.001), and also for the high-density group (p<0.05). The specificity and AUC was higher for mammography in comparison to CBBCT (p<0.05 and p<0.001). The interobserver agreement (ICC) between the readers was 90% (95% CI: 86-93%) for mammography and 87% (95% CI: 82-91%) for CBBCT. Compared with two-view mammography, non-contrast CBBCT has higher sensitivity, lower specificity, and lower AUC for breast mass detection in both high and low density breasts. • Overall sensitivity for non-contrast CBBCT ranged between 88%-91%. • Sensitivity was higher for CBBCT than mammography in both density types (p<0.001). • Specificity was higher for mammography than CBBCT in both density types (p<0.05). • AUC was larger for mammography than CBBCT in both density types (p<0.001).
Amanullah, Sarah; Okudolo, Joseph; Rahmatnejad, Kamran; Lin, Shuai-Chun; Wizov, Sheryl S; Manzi Muhire, Remy S; Hark, Lisa A; Zheng, Cindy X; Zhan, Tingting; Spaeth, George L
2017-12-01
To evaluate the correlation between contrast sensitivity (CS) and retinal nerve fiber layer (RNFL) in different areas of vision. This report is a sub-analysis of a prospective, observational cohort study investigating changes in performance-based assessment, vision-related quality of life, and clinical measures in patients with moderate to advanced glaucoma. The study included 161 participants with at least a 2-year history of glaucoma who underwent annual testing for 4 years. Contrast sensitivity was measured using the Spaeth/Richman contrast sensitivity (SPARCS) test, while RNFL thickness (RNFLT) was measured using Cirrus optical coherence tomography (OCT). Statistical analyses were performed to determine correlations between CS and RNFLT; the correlations were calculated for each annual visit, totaling four correlation coefficients for each patient over the course of 4 years. The SPARCS score in the left upper area of vision correlated the most strongly with the RNFLT of the inferior quadrant for both eyes at each annual visit, specifically in the seven o'clock sector for the left eye and the six o'clock sector for the right eye (p < 0.05). There were no discernible trends for the correlations between the other areas of CS and RNFL quadrants or clock hours over the 4 years of the study. Linear regression between the SPARCS total score and average RNFLT showed a significant direct correlation at each visit (p < 0.01). Contrast sensitivity in the left upper area of vision for both eyes correlated most strongly with the thickness of the inferior quadrant of the RNFL. These fibers project to the temporal portion of the right occipital lobe, implying a potential center for contrast perception in this area. The longitudinal nature of the study suggests that CS may be a predictive tool for changes in RNFL in patients with glaucoma. Despite this finding, retinal damage and its relationship to CS was diffuse. In addition, SPARCS was shown to predict RNFLT. Further research is warranted to understand how CS can be used as a tool in the clinical setting.
Psychophysical contrast calibration
To, Long; Woods, Russell L; Goldstein, Robert B; Peli, Eli
2013-01-01
Electronic displays and computer systems offer numerous advantages for clinical vision testing. Laboratory and clinical measurements of various functions and in particular of (letter) contrast sensitivity require accurately calibrated display contrast. In the laboratory this is achieved using expensive light meters. We developed and evaluated a novel method that uses only psychophysical responses of a person with normal vision to calibrate the luminance contrast of displays for experimental and clinical applications. Our method combines psychophysical techniques (1) for detection (and thus elimination or reduction) of display saturating nonlinearities; (2) for luminance (gamma function) estimation and linearization without use of a photometer; and (3) to measure without a photometer the luminance ratios of the display’s three color channels that are used in a bit-stealing procedure to expand the luminance resolution of the display. Using a photometer we verified that the calibration achieved with this procedure is accurate for both LCD and CRT displays enabling testing of letter contrast sensitivity to 0.5%. Our visual calibration procedure enables clinical, internet and home implementation and calibration verification of electronic contrast testing. PMID:23643843
Zandrino, Franco; La Paglia, Ernesto; Musante, Francesco
2010-01-01
To assess the diagnostic accuracy of magnetic resonance imaging in local staging of endometrial carcinoma, and to review the results and pitfalls described in the literature. Thirty women with a histological diagnosis of endometrial carcinoma underwent magnetic resonance imaging. Unenhanced T2-weighted and dynamic contrast-enhanced Ti-weighted sequences were obtained. Hysterectomy and salpingo-oophorectomy was performed in all patients. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated for the detection of deep myometrial and cervical infiltration. For deep myometrial infiltration T2-weighted sequences reached a sensitivity of 85%, specificity of 76%, PPV of 73%, NVP of 87%, and accuracy of 80%, while contrast-enhanced scans reached a sensitivity of 90%, specificity of 80%, PPV of 82%, NPV of 89%, and accuracy of 85%. For cervical infiltration T2-weighted sequences reached a sensitivity of 75%, specificity of 88%, PPV of 50%, NPV of 96%, and accuracy of 87%, while contrast-enhanced scans reached a sensitivity of 100%, specificity of 94%, PPV of 75%, NPV of 100%, and accuracy of 95%. Unenhanced and dynamic gadolinium-enhanced magnetic resonance allows accurate assessment of myometrial and cervical infiltration. Information provided by magnetic resonance imaging can define prognosis and management.
Phase-contrast x-ray computed tomography for observing biological specimens and organic materials
NASA Astrophysics Data System (ADS)
Momose, Atsushi; Takeda, Tohoru; Itai, Yuji
1995-02-01
A novel three-dimensional x-ray imaging method has been developed by combining a phase-contrast x-ray imaging technique with x-ray computed tomography. This phase-contrast x-ray computed tomography (PCX-CT) provides sectional images of organic specimens that would produce absorption-contrast x-ray CT images with little contrast. Comparing PCX-CT images of rat cerebellum and cancerous rabbit liver specimens with corresponding absorption-contrast CT images shows that PCX-CT is much more sensitive to the internal structure of organic specimens.
Lai, Xin Jie Angela; Alexander, Jack; He, Ming Guang; Yang, Zhi Kuan; Suttle, Catherine
2012-07-01
Dichoptic visual stimulation may be achieved using shutter goggles and mirror systems. These methods vary in their feasibility for use in children. This study aims to investigate the feasibility of use of a simple trial frame-based system to evaluate interactions in children. Low contrast acuity, contrast sensitivity and alignment sensitivity were measured in the non-dominant eye of 10 normally-sighted children, 14 anisometropic children without amblyopia and 14 anisometropic amblyopic children (aged 5-11 years) using goggles and a trial frame apparatus (TFA). The dominant eye was either fully or partially occluded. The difference in visual functions in the non-dominant eye between the full and partial occlusion conditions was termed the 'interaction index'. Agreement between the TFA and goggles in terms of visual functions and interactions was assessed in anisometropic children with and without amblyopia using the Bland-Altman method and t-test. Training sessions allowed subjects to become accustomed to the systems and tasks. The duration of training, the number of breaks requested by subjects and their willingness to attend further experiments were recorded in 10 subjects from each group and were compared between groups and between systems. Both Bland-Altman and t-test methods indicated acceptable agreement between the TFA and goggles in visual function and interaction measures (p > 0.05), except for contrast sensitivity measured in anisometropic children without amblyopia (p = 0.042). For all subject groups, contrast sensitivity training was significantly longer using goggles than using the TFA (p ≤ 0.001). Significantly more breaks were requested in acuity and contrast sensitivity testing, when goggles were used than when the TFA was used (p < 0.045). Anisometropic children without amblyopia showed a significantly greater willingness to attend more experiments using the TFA than using goggles (p = 0.025). The TFA may be a useful tool in studies of interactions in amblyopes, particularly in studies of children's vision. © 2012 The Authors. Clinical and Experimental Optometry © 2012 Optometrists Association Australia.
FT-Raman spectroscopic study of keratotic materials: horn, hoof and tortoiseshell.
Edwards, H G; Hunt, D E; Sibley, M G
1998-05-01
The Fourier-Transform Raman spectra of some mammalian and reptilian keratins, horn, hoof and tortoiseshell, have been analysed and used for the construction of a database for the identification of highly keratotic samples. The samples investigated were; bovine keratin and hoof, Texas Longhorn cattle horn, kudu horn, tortoiseshell and human finger nail. Significant spectral differences were observed in the 1000-400 cm-1 wavenumber range, which included the conformationally important v(SS) and v(CS) features around 500 and 640 cm-1, respectively. The amide I (1650 cm-1) and amide III (1260 cm-1) bands confirmed that the reptilian keratin studied exists in the beta-sheet conformation, whilst mammalian keratins are predominantly laid down in an alpha-helical conformation. The FT-Raman spectral differences particularly between the horn and hoof specimens are very useful for the non-destructive characterisation of artefacts and provides a novel application of the technique.
Both human-health risk assessments of adverse effects from chronic, environmental exposures to neurotoxics and clinical practice are in need of objective indicators sensitive to the early stages of disruption in neurologic function; risk assessment for the purposes of hazard iden...
Spatial noise and threshold contrasts in LCD displays
NASA Astrophysics Data System (ADS)
Roehrig, Hans; Krupinski, Elizabeth A.; Chawla, Amarpreet S.; Fan, Jiahua; Gandhi, Kunal
2003-05-01
This paper presents the results of initial physical and psycho-physical evaluations of the noise of high resolution LCDs. 5 LCDs were involved, having 4 different pixel structures. Spatial as well as temporal noise was physically measured with the aid of a high-performance CCD camera. Human contrast sensitivity in the presence of spatial noise was determined psycho-physically using periodic stimuli (square-wave patterns) as well as aperiodic stimuli (squares). For the measurements of the human contrast sensitivity, all LCDs were calibrated to the DICOM 14 Grayscale Standard Display Function (GSDF). The results demonstrate that spatial noise is the dominant noise in all LCDs, while temporal noise is insignificant and plays only a minor part. The magnitude of spatial noise of LCDs is in the range between that of CRTs with a P104 and that of CRTs with a P45. Of particular importance with respect to LCD noise is the contribution of the pixel structure to the Noise Power Spectrum, which shows up as sharp spikes at spatial frequencies beyond the LCDs" Nyquist frequency. The paper does not offer any clues about the importance of these spikes on the human contrast sensitivity.
He, Jiang-Chun; Zheng, Jian-Yong; Li, Xin; Yang, Ye; Zhang, Bo-Yang; Chen, Yu; Li, Xian-Feng; Liu, Ying-Ming; Cao, Yi; Zhao, Li; Li, Tian-Chang
2017-08-01
To evaluate the utility of transthoracic contrast echocardiography (cTTE) using vitamin B6 and sodium bicarbonate as contrast agents for diagnosing right-to-left shunt (RLS) caused by patent foramen ovale (PFO) compared to that of transesophageal echocardiography (TEE). We investigated 125 patients admitted to our neurology department with unexplained cerebral infarction and migraine. All patients underwent cTTE using vitamin B6 and sodium bicarbonate as contrast agents, after which they underwent transthoracic echocardiography. The Doppler signal was recorded during the Valsalva maneuver, and TEE examinations were performed. The feasibility, diagnostic sensitivity, and safety of cTTE and TEE for PFO recognition were compared. Evidence of PFO was found in 49 (39.20%) patients with cTTE, more than were detected with TEE (39, 31.20%) (χ 2 =5.0625, P=0.0244). cTTE had a sensitivity of 92.31% and a specificity of 84.88% for diagnosing PFO, showing high concordance with TEE for PFO recognition (κ=0.72). Further, results of a semi-quantitative evaluation of PFO-RLS by cTTE were better than those with TEE (Z=-2.011, P=0.044). No significant adverse reaction was discovered during cTTE examination. cTTE using vitamin B6 and sodium bicarbonate as contrast agents has relatively good sensitivity and specificity for diagnosing RLS caused by PFO when compared with those for TEE. Using vitamin B6 and sodium bicarbonate as contrast agents to perform cTTE is recommended for detecting and diagnosing the PFO due to its simplicity, non-invasive character, low cost, and high feasibility.
Almoqbel, Fahad M; Irving, Elizabeth L; Leat, Susan J
2017-08-01
The purpose of this study was to investigate the development of visual acuity (VA) and contrast sensitivity in children as measured with objective (sweep visually evoked potential) and subjective, psychophysical techniques, including signal detection theory (SDT), which attempts to control for differences in criterion or behavior between adults and children. Furthermore, this study examines the possibility of applying SDT methods with children. Visual acuity and contrast thresholds were measured in 12 children 6 to 7 years old, 10 children 8 to 9 years old, 10 children 10 to 12 years old, and 16 adults. For sweep visually evoked potential measurements, spatial frequency was swept from 1 to 40 cpd to measure VA, and contrast of sine-wave gratings (1 or 8 cpd) was swept from 0.33 to 30% to measure contrast thresholds. For psychophysical measurements, VA and contrast thresholds (1 or 8 cpd) were measured using a temporal two-alternative forced-choice staircase procedure and also with a yes-no SDT procedure. Optotype (logMAR [log of the minimum angle of resolution]) VA was also measured. The results of the various procedures were in agreement showing that there are age-related changes in threshold values and logMAR VA after the age of 6 years and that these visual functions do not become adult-like until the age of 8 to 9 years at the earliest. It was also found that children can participate in SDT procedures and do show differences in criterion compared with adults in psychophysical testing. These findings confirm a slightly later development of VA and contrast sensitivity (8 years or older) and indicate the importance of using SDT or forced-choice procedures in any developmental study to attempt to overcome the effect of criterion in children.
Diedrich, Erich; Schaeffel, Frank
2009-11-01
The chicken has been extensively studied as an animal model for myopia because its eye growth is tightly controlled by visual experience. It has been found that the retina controls the axial eye growth rates depending on the amount and the sign of defocus imposed in the projected image. Glucagonergic amacrine cells were discovered that appear to encode for the sign of imposed defocus. It is not clear whether the downstream neurons, the retinal ganglion cells, still have access to this information-and whether it ultimately reaches the brain. We have analyzed the spike rates of chicken retinal ganglion cells in vitro using a microelectrode array. For this purpose, we initially defined spatial resolution and contrast sensitivity in vitro. Two classes of chicken retinal ganglions were found, depending on the linearity of their responses with increasing contrast. Responses generally declined with increasing defocus of the visual stimulus. These responses were well predicted by the modulation transfer function for a diffraction-limited defocused optical system, the first Bessel function. Thus, the studied retinal ganglion cells did not distinguish between a loss of contrast at a given spatial frequency due to reduced contrast of the stimulus pattern or because the pattern was presented out of focus. Furthermore, there was no indication that the retinal ganglion cells responded differently to defocus of either sign, at least for the cells that were recorded in this study.
Bosworth, Rain; Robbins, Shira L.; Granet, David B.; Dobkins, Karen
2013-01-01
Background The current study assessed whether contrast sensitivity is affected in preterm infants with a history of spontaneously regressed retinopathy of prematurity (ROP, Stages 1–3). Specifically, we employed luminance (light/dark) and chromatic (red/green) stimuli, which are mediated by the magnocellular (M) and parvocellular (P) subcortical pathways, respectively. Methods Contrast sensitivity (CS) was measured using forced choice preferential looking testing in 21 infants with a history of ROP and 41 control preterm infants who were born prematurely but did not develop ROP, tested between 8 and 47 weeks (2–11 months) postterm age. Infants were presented with chromatic and luminance drifting sinusoidal gratings, which appeared randomly on the left or right side of the monitor on each trial. The contrast of the stimuli varied across trials and was defined in terms of root mean squared cone contrast for long- and medium-wavelength cones. Results Between 8 and 25 weeks postterm, ROP infants had significantly worse CS, and there was a trend for greater impairment for Luminance than Chromatic CS. This delay was not seen at older ages between 26 and 47 weeks postterm. Conclusions These findings are consistent with the concept that early maturation of the M pathway is vulnerable to biological insult, as in the case of ROP, to a greater extent than is the P pathway. PMID:23744448
Early-Stage Visual Processing and Cortical Amplification Deficits in Schizophrenia
Butler, Pamela D.; Zemon, Vance; Schechter, Isaac; Saperstein, Alice M.; Hoptman, Matthew J.; Lim, Kelvin O.; Revheim, Nadine; Silipo, Gail; Javitt, Daniel C.
2005-01-01
Background Patients with schizophrenia show deficits in early-stage visual processing, potentially reflecting dysfunction of the magnocellular visual pathway. The magnocellular system operates normally in a nonlinear amplification mode mediated by glutamatergic (N-methyl-d-aspartate) receptors. Investigating magnocellular dysfunction in schizophrenia therefore permits evaluation of underlying etiologic hypotheses. Objectives To evaluate magnocellular dysfunction in schizophrenia, relative to known neurochemical and neuroanatomical substrates, and to examine relationships between electrophysiological and behavioral measures of visual pathway dysfunction and relationships with higher cognitive deficits. Design, Setting, and Participants Between-group study at an inpatient state psychiatric hospital and out-patient county psychiatric facilities. Thirty-three patients met DSM-IV criteria for schizophrenia or schizoaffective disorder, and 21 nonpsychiatric volunteers of similar ages composed the control group. Main Outcome Measures (1) Magnocellular and parvocellular evoked potentials, analyzed using nonlinear (Michaelis-Menten) and linear contrast gain approaches; (2) behavioral contrast sensitivity measures; (3) white matter integrity; (4) visual and nonvisual neuropsychological measures, and (5) clinical symptom and community functioning measures. Results Patients generated evoked potentials that were significantly reduced in response to magnocellular-biased, but not parvocellular-biased, stimuli (P=.001). Michaelis-Menten analyses demonstrated reduced contrast gain of the magnocellular system (P=.001). Patients showed decreased contrast sensitivity to magnocellular-biased stimuli (P<.001). Evoked potential deficits were significantly related to decreased white matter integrity in the optic radiations (P<.03). Evoked potential deficits predicted impaired contrast sensitivity (P=.002), which was in turn related to deficits in complex visual processing (P≤.04). Both evoked potential (P≤.04) and contrast sensitivity (P=.01) measures significantly predicted community functioning. Conclusions These findings confirm the existence of early-stage visual processing dysfunction in schizophrenia and provide the first evidence that such deficits are due to decreased nonlinear signal amplification, consistent with glutamatergic theories. Neuroimaging studies support the hypothesis of dysfunction within low-level visual pathways involving thalamocortical radiations. Deficits in early-stage visual processing significantly predict higher cognitive deficits. PMID:15867102
Barrios, Shannon L.; Namyst, Anna M.; Lau, Ellen F.; Feldman, Naomi H.; Idsardi, William J.
2016-01-01
To attain native-like competence, second language (L2) learners must establish mappings between familiar speech sounds and new phoneme categories. For example, Spanish learners of English must learn that [d] and [ð], which are allophones of the same phoneme in Spanish, can distinguish meaning in English (i.e., /deɪ/ “day” and /ðeɪ/ “they”). Because adult listeners are less sensitive to allophonic than phonemic contrasts in their native language (L1), novel target language contrasts between L1 allophones may pose special difficulty for L2 learners. We investigate whether advanced Spanish late-learners of English overcome native language mappings to establish new phonological relations between familiar phones. We report behavioral and magnetoencepholographic (MEG) evidence from two experiments that measured the sensitivity and pre-attentive processing of three listener groups (L1 English, L1 Spanish, and advanced Spanish late-learners of English) to differences between three nonword stimulus pairs ([idi]-[iði], [idi]-[iɾi], and [iði]-[iɾi]) which differ in phones that play a different functional role in Spanish and English. Spanish and English listeners demonstrated greater sensitivity (larger d' scores) for nonword pairs distinguished by phonemic than by allophonic contrasts, mirroring previous findings. Spanish late-learners demonstrated sensitivity (large d' scores and MMN responses) to all three contrasts, suggesting that these L2 learners may have established a novel [d]-[ð] contrast despite the phonological relatedness of these sounds in the L1. Our results suggest that phonological relatedness influences perceived similarity, as evidenced by the results of the native speaker groups, but may not cause persistent difficulty for advanced L2 learners. Instead, L2 learners are able to use cues that are present in their input to establish new mappings between familiar phones. PMID:27445949
Diether, S; Schaeffel, F
1999-07-01
Experiments in animal models have shown that the retinal analyzes the image to identify the position of the plane of focus and fine-tunes the growth of the underlying sclera. It is fundamental to the understanding of the development of refractive errors to know which image features are processed. Since the position of the image plane fluctuates continuously with accommodative status and viewing distance, a meaningful control of refractive development can only occur by an averaging procedure with a long time constant. As a candidate for a retinal signal for enhanced eye growth and myopia we propose the level of contrast adaptation which varies with the average amount of defocus. Using a behavioural paradigm, we have found in chickens (1) that contrast adaptation (CA, here referred to as an increase in contrast sensitivity) occurs at low spatial frequencies (0.2 cyc/deg) already after 1.5 h of wearing frosted goggles which cause deprivation myopia, (2) that CA also occurs with negative lenses (-7.4D) and positive lenses (+6.9D) after 1.5 h, at least if accommodation is paralyzed and, (3) that CA occurs at a retinal level or has, at least, a retinal component. Furthermore, we have studied the effects of atropine and reserpine, which both suppress myopia development, on CA. Quisqualate, which causes retinal degeneration but leaves emmetropization functional, was also tested. We found that both atropine and reserpine increase contrast sensitivity to a level where no further CA could be induced by frosted goggles. Quisqualate increased only the variability of refractive development and of contrast sensitivity. Taken together, CA occurring during extended periods of defocus is a possible candidate for a retinal error signal for myopia development. However, the situation is complicated by the fact that there must be a second image processing mode generating a powerful inhibitory growth signal if the image is in front of the retina, even with poor images (Diether, S., & Schaeffel, F. (1999).
Song, Feng-wei; Sun, Zhao-hui; Yang, Yi; Wang, Li-ping; Tang, Xia-jing; Chen, Bin-bin; Yu, Xiao-ning
2014-01-01
To investigate the relationship between the characteristics of spatial vision deficit and the degree of amblyopia in monocular amblyopes, and to analyze its mechanism with the theory of Magnocellular and Parvocellular pathways. One hundred and eleven patients with monocular amblyopes aged 7-34 were included in this study. Distance best corrected visual acuity (BCVA) in logMAR units and contrast sensitivity function test were performed on both eyes in all patients with ETDRS digital visual chart and functional test system OPTECR 6500. The spatial vision of amblyopic and non-amblyopic eyes was evaluated by the AULCSF, Smax, Frmax and cutSF derived from the curve of contrast sensitivity function. The degree of amblyopia was significantly correlated with the difference of AULCSF between the amblyopic and non-amblyopia eyes (r=-0.83, P<0.01). BCVA of amblyopic eyes was significantly correlated with AULCSF, CutSF, Smax, Frmax(r=-0.68, -0.80, -0.73, -0.56, respectively; P<0.01). In amblyopic eyes, significant difference in BCVA, AULCSF, Smax, Frmax and CutSF was seen among different amblyopic groups (P<0.01), which was defined by the degree of amblyopia. In non-amblyopic eyes,no significant difference in BCVA, AULCSF, Smax, Frmax and CutSF was noted among different amblyopic groups (P>0.05). In mild amblyopes, no significant difference in AULCSF and Frmax was found between the amblyopic eyes and non-amblyopic eyes (P>0.05), while Smax and CutSF were significantly different. However, in moderate and severe amblyopes, significant differences in BCVA, AULCSF, Smax, Frmax and CutSF was seen between the amblyopic and non-amblyopic eyes (P<0.01). In amblyopic eyes, significant difference in contrast sensitivity was noted in all kinds of spatial frequencies among different amblyopic groups (P<0.01), and in non-amblyopic eyes, significant differences in contrast sensitivity was not seen in all kinds of spatial frequencies among different amblyopic groups. The AULCSF, CutSF, Smax and Frmax are accorded with visual acuity for evaluation of the spatial vision of amblyopia. As the severity of amblyopia increases, the overall function of spatial vision in amblyopic eyes gradually decreases, the resolution ability of high spatial frequency is gradually weaken, the peak of contrast detection function gradually descends, and the optimal spatial frequency for contrast detection offsets toward low level of spatial frequency. Mild monocular amblyopia produces spatial contrast sensitivity loss in high spatial vision, suggesting there may be decreased sensitivity of the Parvocellular pathway, and no significant anomalous processing of Magnocellular Pathway. Whereas, in moderate and severe amblyopes, a generalized loss of sensitivity is observed at each spatial frequency. This result shows that both Magnocellular and Parvocellular pathways are damaged in different degrees, especially in Parvocellular pathway.
Padmanabhan, Prema; Mrochen, Michael; Basuthkar, Subam; Viswanathan, Deepa; Joseph, Roy
2008-03-01
To compare the outcomes of wavefront-guided and wavefront-optimized treatment in fellow eyes of patients having laser in situ keratomileusis (LASIK) for myopia. Medical and Vision Research Foundation, Tamil Nadu, India. This prospective comparative study comprised 27 patients who had wavefront-guided LASIK in 1 eye and wavefront-optimized LASIK in the fellow eye. The Hansatome (Bausch & Lomb) was used to create a superior-hinged flap and the Allegretto laser (WaveLight Laser Technologie AG), for photoablation. The Allegretto wave analyzer was used to measure ocular wavefront aberrations and the Functional Acuity Contrast Test chart, to measure contrast sensitivity before and 1 month after LASIK. The refractive and visual outcomes and the changes in aberrations and contrast sensitivity were compared between the 2 treatment modalities. One month postoperatively, 92% of eyes in the wavefront-guided group and 85% in the wavefront-optimized group had uncorrected visual acuity of 20/20 or better; 93% and 89%, respectively, had a postoperative spherical equivalent refraction of +/-0.50 diopter. The differences between groups were not statistically significant. Wavefront-guided LASIK induced less change in 18 of 22 higher-order Zernike terms than wavefront-optimized LASIK, with the change in positive spherical aberration the only statistically significant one (P= .01). Contrast sensitivity improved at the low and middle spatial frequencies (not statistically significant) and worsened significantly at high spatial frequencies after wavefront-guided LASIK; there was a statistically significant worsening at all spatial frequencies after wavefront-optimized LASIK. Although both wavefront-guided and wavefront-optimized LASIK gave excellent refractive correction results, the former induced less higher-order aberrations and was associated with better contrast sensitivity.
Google Glass Glare: disability glare produced by a head-mounted visual display.
Longley, Chris; Whitaker, David
2016-03-01
Head mounted displays are a type of wearable technology - a market that is projected to expand rapidly over the coming years. Probably the most well known example is the device Google Glass (or 'Glass'). Here we investigate the extent to which the device display can interfere with normal visual function by producing monocular disability glare. Contrast sensitivity was measured in two normally sighted participants, 32 and 52 years of age. Data were recorded for the right eye, the left eye and then again in a binocular condition. Measurements were taken both with and without the Glass in place, across a range of stimulus luminance levels using a two-alternative forced-choice methodology. The device produced a significant reduction in contrast sensitivity in the right eye (>0.5 log units). The level of disability glare increased as stimulus luminance was reduced in a manner consistent with intraocular light scatter, resulting in a veiling retinal illuminance. Sensitivity in the left eye was unaffected. A significant reduction in binocular contrast sensitivity occurred at lower luminance levels due to a loss of binocular summation, although binocular sensitivity was not found to fall below the sensitivity of the better monocular level (binocular inhibition). Head mounted displays such as Google Glass have the potential to cause significant disability glare in the eye exposed to the visual display, particularly under conditions of low luminance. They can also cause a more modest binocular reduction in sensitivity by eliminating the benefits of binocular summation. © 2015 The Authors Ophthalmic & Physiological Optics © 2015 The College of Optometrists.
Relating Standardized Visual Perception Measures to Simulator Visual System Performance
NASA Technical Reports Server (NTRS)
Kaiser, Mary K.; Sweet, Barbara T.
2013-01-01
Human vision is quantified through the use of standardized clinical vision measurements. These measurements typically include visual acuity (near and far), contrast sensitivity, color vision, stereopsis (a.k.a. stereo acuity), and visual field periphery. Simulator visual system performance is specified in terms such as brightness, contrast, color depth, color gamut, gamma, resolution, and field-of-view. How do these simulator performance characteristics relate to the perceptual experience of the pilot in the simulator? In this paper, visual acuity and contrast sensitivity will be related to simulator visual system resolution, contrast, and dynamic range; similarly, color vision will be related to color depth/color gamut. Finally, we will consider how some characteristics of human vision not typically included in current clinical assessments could be used to better inform simulator requirements (e.g., relating dynamic characteristics of human vision to update rate and other temporal display characteristics).
NASA Astrophysics Data System (ADS)
Rand, Danielle; Derdak, Zoltan; Carlson, Rolf; Wands, Jack R.; Rose-Petruck, Christoph
2015-10-01
Hepatocellular carcinoma (HCC) is one of the most common malignant tumors worldwide and is almost uniformly fatal. Current methods of detection include ultrasound examination and imaging by CT scan or MRI; however, these techniques are problematic in terms of sensitivity and specificity, and the detection of early tumors (<1 cm diameter) has proven elusive. Better, more specific, and more sensitive detection methods are therefore urgently needed. Here we discuss the application of a newly developed x-ray imaging technique called Spatial Frequency Heterodyne Imaging (SFHI) for the early detection of HCC. SFHI uses x-rays scattered by an object to form an image and is more sensitive than conventional absorption-based x-radiography. We show that tissues labeled in vivo with gold nanoparticle contrast agents can be detected using SFHI. We also demonstrate that directed targeting and SFHI of HCC tumors in a mouse model is possible through the use of HCC-specific antibodies. The enhanced sensitivity of SFHI relative to currently available techniques enables the x-ray imaging of tumors that are just a few millimeters in diameter and substantially reduces the amount of nanoparticle contrast agent required for intravenous injection relative to absorption-based x-ray imaging.
Color vision in ADHD: part 2--does attention influence color perception?
Kim, Soyeon; Al-Haj, Mohamed; Fuller, Stuart; Chen, Samantha; Jain, Umesh; Carrasco, Marisa; Tannock, Rosemary
2014-10-24
To investigate the impact of exogenous covert attention on chromatic (blue and red) and achromatic visual perception in adults with and without Attention Deficit Hyperactivity Disorder (ADHD). Exogenous covert attention, which is a transient, automatic, stimulus-driven form of attention, is a key mechanism for selecting relevant information in visual arrays. 30 adults diagnosed with ADHD and 30 healthy adults, matched on age and gender, performed a psychophysical task designed to measure the effects of exogenous covert attention on perceived color saturation (blue, red) and contrast sensitivity. The effects of exogenous covert attention on perceived blue and red saturation levels and contrast sensitivity were similar in both groups, with no differences between males and females. Specifically, exogenous covert attention enhanced the perception of blue saturation and contrast sensitivity, but it had no effect on the perception of red saturation. The findings suggest that exogenous covert attention is intact in adults with ADHD and does not account for the observed impairments in the perception of chromatic (blue and red) saturation.
Development of nanostars as a biocompatible tumor contrast agent: toward in vivo SERS imaging.
D'Hollander, Antoine; Mathieu, Evelien; Jans, Hilde; Vande Velde, Greetje; Stakenborg, Tim; Van Dorpe, Pol; Himmelreich, Uwe; Lagae, Liesbet
2016-01-01
The need for sensitive imaging techniques to detect tumor cells is an important issue in cancer diagnosis and therapy. Surface-enhanced Raman scattering (SERS), realized by chemisorption of compounds suitable for Raman spectroscopy onto gold nanoparticles, is a new method for detecting a tumor. As a proof of concept, we studied the use of biocompatible gold nanostars as sensitive SERS contrast agents targeting an ovarian cancer cell line (SKOV3). Due to a high intracellular uptake of gold nanostars after 6 hours of exposure, they could be detected and located with SERS. Using these nanostars for passive targeting after systemic injection in a xenograft mouse model, a detectable signal was measured in the tumor and liver in vivo. These signals were confirmed by ex vivo SERS measurements and darkfield microscopy. In this study, we established SERS nanostars as a highly sensitive contrast agent for tumor detection, which opens the potential for their use as a theranostic agent against cancer.
Impact of Albedo Contrast Between Cirrus and Boundary-Layer Clouds on Climate Sensitivity
NASA Technical Reports Server (NTRS)
Chou, Ming-Dah; Lindzen, R. S.; Hou, A. Y.; Lau, William K. M. (Technical Monitor)
2001-01-01
In assessing the iris effect suggested by Lindzen et al. (2001), Fu et al. (2001) found that the response of high-level clouds to the sea surface temperature had an effect of reducing the climate sensitivity to external radiative forcing, but the effect was not as strong as LCH found. This weaker reduction in climate sensitivity was due to the smaller contrasts in albedos and effective emitting temperatures between cirrus clouds and the neighboring regions. FBH specified the albedos and the outgoing longwave radiation (OLR) in the LCH 3.5-box radiative-convective model by requiring that the model radiation budgets at the top of the atmosphere be consistent with that inferred from the Earth Radiation Budget Experiment (ERBE). In point of fact, the constraint by radiation budgets alone is not sufficient for deriving the correct contrast in radiation properties between cirrus clouds and the neighboring regions, and the approach of FBH to specifying those properties is, we feel inappropriate for assessing the iris effect.
Monte Carlo design of optimal wire mesh collimator for breast tumor imaging process
NASA Astrophysics Data System (ADS)
Saad, W. H. M.; Roslan, R. E.; Mahdi, M. A.; Choong, W.-S.; Saion, E.; Saripan, M. I.
2011-08-01
This paper presents the modeling of breast tumor imaging process using wire mesh collimator gamma camera. Previous studies showed that the wire mesh collimator has a potential to improve the sensitivity of the tumor detection. In this paper, we extend our research significantly, to find an optimal configuration of the wire mesh collimator specifically for semi-compressed breast tumor detection, by looking into four major factors: weight, sensitivity, spatial resolution and tumor contrast. The numbers of layers in the wire mesh collimator is varied to optimize the collimator design. The statistical variations of the results are studied by simulating multiple realizations for each experiment using different starting random numbers. All the simulation environments are modeled using Monte Carlo N-Particle Code (MCNP). The quality of the detection is measured directly by comparing the sensitivity, spatial resolution and tumor contrast of the images produced by the wire mesh collimator and benchmarked that with a standard multihole collimator. The proposed optimal configuration of the wire mesh collimator is optimized by selecting the number of layers in wire mesh collimator, where the tumor contrast shows a relatively comparable value to the multihole collimator, when it is tested with uniformly semi-compressed breast phantom. The wire mesh collimator showed higher number of sensitivity because of its loose arrangement while the spatial resolution of wire mesh collimator does not shows much different compared to the multihole collimator. With a relatively good tumor contrast and spatial resolution, and increased in sensitivity, a new proposed wire mesh collimator gives a significant improvement in the wire mesh collimator design for breast cancer imaging process. The proposed collimator configuration is reduced to 44.09% from the total multihole collimator weight.
Korosoglou, Grigorios; Dubart, Alain-Eric; DaSilva, K Gaspar C; Labadze, Nino; Hardt, Stefan; Hansen, Alexander; Bekeredjian, Raffi; Zugck, Christian; Zehelein, Joerg; Katus, Hugo A; Kuecherer, Helmut
2006-01-01
Little is known about the incremental value of real-time myocardial contrast echocardiography (MCE) as an adjunct to pharmacologic stress testing. This study was performed to evaluate the diagnostic value of MCE to detect abnormal myocardial perfusion by technetium Tc 99m sestamibi-single photon emission computed tomography (SPECT) and anatomically significant coronary artery disease (CAD) by angiography. Myocardial contrast echocardiography was performed at rest and during vasodilator stress in consecutive patients (N = 120) undergoing SPECT imaging for known or suspected CAD. Myocardial opacification, wall motion, and tracer uptake were visually analyzed in 12 myocardial segments by 2 pairs of blinded observers. Concordance between the 2 methods was assessed using the kappa statistic. Of 1356 segments, 1025 (76%) were interpretable by MCE, wall motion, and SPECT. Sensitivity of wall motion was 75%, specificity 83%, and accuracy 81% for detecting abnormal myocardial perfusion by SPECT (kappa = 0.53). Myocardial contrast echocardiography and wall motion together yielded significantly higher sensitivity (85% vs 74%, P < .05), specificity of 83%, and accuracy of 85% (kappa = 0.64) for the detection of abnormal myocardial perfusion. In 89 patients who underwent coronary angiography, MCE and wall motion together yielded higher sensitivity (83% vs 64%, P < .05) and accuracy (77% vs 68%, P < .05) but similar specificity (72%) compared with SPECT for the detection of high-grade, stenotic (> or = 75%) coronary lesions. Assessment of myocardial perfusion adds value to conventional stress echocardiography by increasing its sensitivity for the detection of functionally abnormal myocardial perfusion. Myocardial contrast echocardiography and wall motion together provide higher sensitivity and accuracy for detection of CAD compared with SPECT.
Kim, Young Jin; Hur, Jin; Shim, Chi-Young; Lee, Hye-Jeong; Ha, Jong-Won; Choe, Kyu Ok; Heo, Ji Hoe; Choi, Eui-Young; Choi, Byoung Wook
2009-01-01
To evaluate the clinical feasibility and accuracy of 64-section multidetector computed tomography (CT) compared with transesophageal echocardiography (TEE) for diagnosis of a patent foramen ovale (PFO). Institutional review board approval was obtained for this retrospective study. The study included 152 consecutive stroke patients (mean age, 61.7 years; 98 men, 54 women) who underwent both cardiac multidetector CT and TEE. Electrocardiographically gated cardiac CT was performed with a 64-section CT scanner by using a saline-chaser contrast agent injection technique. A contrast agent jet from the contrast agent-filled left atrium (LA) to the saline-filled right atrium (RA) and channel-like appearance of the interatrial septum (IAS) were evaluated on axial and oblique sagittal CT images. Two-dimensional and Doppler TEE were performed to detect PFO. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of CT were obtained with TEE as the reference standard. A PFO was present in 26 patients at TEE. On CT images, a left-to-right contrast agent jet toward the inferior vena cava was noted in 21 patients (sensitivity, 73.1%; specificity, 98.4%; PPV, 90.5%; NPV, 94.7%). Channel-like appearance of the IAS was detected in 38 patients (sensitivity, 76.9%; specificity, 85.7%; PPV, 52.6%; NPV, 94.7%). Channel-like appearance of the IAS was noted in all patients who had a contrast agent jet. A contrast agent jet from LA to RA toward the inferior vena cava with channel-like appearance of the IAS on CT images confirms the presence of a PFO. (c) RSNA, 2008.
Gillespie-Gallery, Hanna; Konstantakopoulou, Evgenia; Harlow, Jonathan A; Barbur, John L
2013-09-09
It is challenging to separate the effects of normal aging of the retina and visual pathways independently from optical factors, decreased retinal illuminance, and early stage disease. This study determined limits to describe the effect of light level on normal, age-related changes in monocular and binocular functional contrast sensitivity. We recruited 95 participants aged 20 to 85 years. Contrast thresholds for correct orientation discrimination of the gap in a Landolt C optotype were measured using a 4-alternative, forced-choice (4AFC) procedure at screen luminances from 34 to 0.12 cd/m(2) at the fovea and parafovea (0° and ±4°). Pupil size was measured continuously. The Health of the Retina index (HRindex) was computed to capture the loss of contrast sensitivity with decreasing light level. Participants were excluded if they exhibited performance outside the normal limits of interocular differences or HRindex values, or signs of ocular disease. Parafoveal contrast thresholds showed a steeper decline and higher correlation with age at the parafovea than the fovea. Of participants with clinical signs of ocular disease, 83% had HRindex values outside the normal limits. Binocular summation of contrast signals declined with age, independent of interocular differences. The HRindex worsens more rapidly with age at the parafovea, consistent with histologic findings of rod loss and its link to age-related degenerative disease of the retina. The HRindex and interocular differences could be used to screen for and separate the earliest stages of subclinical disease from changes caused by normal aging.
Validation of the shake test for detecting freeze damage to adsorbed vaccines.
Kartoglu, Umit; Ozgüler, Nejat Kenan; Wolfson, Lara J; Kurzatkowski, Wiesław
2010-08-01
To determine the validity of the shake test for detecting freeze damage in aluminium-based, adsorbed, freeze-sensitive vaccines. A double-blind crossover design was used to compare the performance of the shake test conducted by trained health-care workers (HCWs) with that of phase contrast microscopy as a "gold standard". A total of 475 vials of 8 different types of World Health Organization prequalified freeze-sensitive vaccines from 10 different manufacturers were used. Vaccines were kept at 5 degrees C. Selected numbers of vials from each type were then exposed to -25 degrees C and -2 degrees C for 24-hour periods. There was complete concordance between HCWs and phase-contrast microscopy in identifying freeze-damaged vials and non-frozen samples. Non-frozen samples showed a fine-grain structure under phase contrast microscopy, but freeze-damaged samples showed large conglomerates of massed precipitates with amorphous, crystalline, solid and needle-like structures. Particles in the non-frozen samples measured from 1 microm (vaccines against diphtheria-tetanus-pertussis; Haemophilus influenzae type b; hepatitis B; diphtheria-tetanus-pertussis-hepatitis B) to 20 microm (diphtheria and tetanus vaccines, alone or in combination). By contrast, aggregates in the freeze-damaged samples measured up to 700 microm (diphtheria-tetanus-pertussis) and 350 microm on average. The shake test had 100% sensitivity, 100% specificity and 100% positive predictive value in this study, which confirms its validity for detecting freeze damage to aluminium-based freeze-sensitive vaccines.
Kara-Junior, Newton; Espindola, Rodrigo F; Gomes, Beatriz A F; Ventura, Bruna; Smadja, David; Santhiago, Marcony R
2011-12-01
To evaluate the possible side effects and potential protection 5 years after implantation of an intraocular lens (IOL) with a blue-light filter (yellow tinted). Ophthalmology Department, University of São Paulo, São Paulo, Brazil. Prospective randomized clinical study. Patients with bilateral visually significant cataract randomly received an ultraviolet (UV) and blue light-filtering IOL (Acrysof Natural SN60AT) in 1 eye and an acrylic UV light-filtering only IOL (Acrysof SA60AT) in the fellow eye. The primary outcome measures were contrast sensitivity, color vision, and macular findings 5 years after surgery. The study enrolled 60 eyes of 30 patients. There were no significant clinical or optical coherence tomography findings in terms of age-related macular degeneration in any eye. There were no statistically significant differences in central macular thickness between the 2 IOL groups (P=.712). There were also no significant between-group differences under photopic or scotopic conditions at any spatial frequency studied. No statistically significant differences in the color discrimination test were found between the 2 IOL groups (P=.674). After 5 years, there were no significant differences in color perception, scotopic contrast sensitivity, or photopic contrast sensitivity between the blue light-filtering (yellow-tinted) IOL and the IOL with a UV-light filter only (untinted). The potential advantage of the tinted IOL in providing protection to macular cells remains unclear. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Spatial frequency discrimination learning in normal and developmentally impaired human vision
Astle, Andrew T.; Webb, Ben S.; McGraw, Paul V.
2010-01-01
Perceptual learning effects demonstrate that the adult visual system retains neural plasticity. If perceptual learning holds any value as a treatment tool for amblyopia, trained improvements in performance must generalise. Here we investigate whether spatial frequency discrimination learning generalises within task to other spatial frequencies, and across task to contrast sensitivity. Before and after training, we measured contrast sensitivity and spatial frequency discrimination (at a range of reference frequencies 1, 2, 4, 8, 16 c/deg). During training, normal and amblyopic observers were divided into three groups. Each group trained on a spatial frequency discrimination task at one reference frequency (2, 4, or 8 c/deg). Normal and amblyopic observers who trained at lower frequencies showed a greater rate of within task learning (at their reference frequency) compared to those trained at higher frequencies. Compared to normals, amblyopic observers showed greater within task learning, at the trained reference frequency. Normal and amblyopic observers showed asymmetrical transfer of learning from high to low spatial frequencies. Both normal and amblyopic subjects showed transfer to contrast sensitivity. The direction of transfer for contrast sensitivity measurements was from the trained spatial frequency to higher frequencies, with the bandwidth and magnitude of transfer greater in the amblyopic observers compared to normals. The findings provide further support for the therapeutic efficacy of this approach and establish general principles that may help develop more effective protocols for the treatment of developmental visual deficits. PMID:20832416
Aguirre-Sierra, Aránzazu; Alonso, Alvaro; Camargo, Julio A
2011-05-01
In contrast to aquatic vertebrates, there is scarce available information on the contrasting tolerance to fluoride of different life stages and/or sizes of aquatic invertebrates. The purpose of this study was to assess the likely differences in sensitivity between juveniles and adults of the aquatic snail Potamopyrgus antipodarum (Hydrobiidae, Mollusca) to short-term (4 days) toxicity of fluoride ion (F(-)). LC50 and EC50 values for juveniles were significantly lower than those for adults at 24, 48, 72 and 96 h. Based on our results, the use of fluoride data of bioassays with juveniles should provide more protective water quality criteria than data from adult stage. © Springer Science+Business Media, LLC 2011
Engineering Gd-loaded nanoparticles to enhance MRI sensitivity via T1 shortening
NASA Astrophysics Data System (ADS)
Bruckman, Michael A.; Yu, Xin; Steinmetz, Nicole F.
2013-11-01
Magnetic resonance imaging (MRI) is a noninvasive imaging technique capable of obtaining high-resolution anatomical images of the body. Major drawbacks of MRI are the low contrast agent sensitivity and inability to distinguish healthy tissue from diseased tissue, making early detection challenging. To address this technological hurdle, paramagnetic contrast agents have been developed to increase the longitudinal relaxivity, leading to an increased signal-to-noise ratio. This review focuses on methods and principles that enabled the design and engineering of nanoparticles to deliver contrast agents with enhanced ionic relaxivities. Different engineering strategies and nanoparticle platforms will be compared in terms of their manufacturability, biocompatibility properties, and their overall potential to make an impact in clinical MR imaging.
NASA Astrophysics Data System (ADS)
Souza, T. R.; Baptista, R.
2003-08-01
As estrelas secundárias em variáveis cataclí smicas (VCs) e binárias-x de baixa massa (BXBMs) são cruciais para o entendimento da origem, evolução e comportamento destas binárias interagentes. Elas são estrelas magneticamente ativas submetidas a condições ambientais extremas [e.g., estão muito próximas de uma fonte quente e irradiante; têm rotação extremamente rápida e forma distorcida; estão perdendo massa a taxas de 10-8-10-10 M¤/ano] que contribuem para que suas propriedades sejam distintas das de estrelas de mesma massa na seqüência principal. Por outro lado, o padrão de irradiação na face da secundária fornece informação sobre a geometria das estruturas de acréscimo em torno da estrela primária. Assim, a obtenção de imagens da superfície destas estrelas é de grande interesse astrofísico. A Tomografia Roche usa as variações no perfil das linhas de emissão/absorção da estrela secundária em função da fase orbital para mapear a distribuição de brilho em sua superfície. Neste trabalho apresentamos os resultados iniciais do desenvolvimento de um programa para o mapeamento da distribuição de brilho na superfí cie das estrelas secundárias em VCs e BXBMs com técnicas de astro-tomografia. Presentemente temos em operação um código que simula as variações no perfil das linhas em conseqüência de efeito Doppler resultante da combinação de rotação e translação de uma estrela em forma de lobo de Roche em torno do centro de massa da binária, em função da distribuição de brilho na superfície desta estrela. O código igualmente produz a curva de luz resultante das variações de aspecto da estrela em função da fase orbital (variações elipsoidais).
Huovinen, Tuomas; Syrjänpää, Markku; Sanmark, Hanna; Seppä, Titta; Akter, Sultana; Khan, Liton Md Ferdhos; Lamminmäki, Urpo
2014-09-19
Filamentous phage display has become an ordinary tool to engineer antibody fragments. Several capsid proteins have been applied for displaying antibodies, of which gene III (p3) protein is used the most followed by experiments with gene IX (p9) protein. Despite the popularity, there are no library scale studies to objectively compare differences in the selection performance of the libraries, when displayed via different capsid proteins. In this study, an identical antibody repertoire was displayed as Fab fragments on p9, p3 and truncated p3 (p3Δ). In addition, the library clones were displayed as ScFv fragments on p3Δ and the Fab-p3 display valency was modulated by hyperphage and VCS-M13 superinfections. The selection performances of the libraries were followed in repeated parallel panning reactions against streptavidin (STR) and digoxigenin (DIG). Selection was successful with all display formats, but the enrichment of specific clones from Fab-p9 library was clearly less efficient than from the other libraries. The most diverse outputs were obtained from p3Δ display and the highest affinity anti-DIG antibodies from the ScFv repertoire. Unfortunately, the number of retrieved specific clones was too low for explicit analysis of the differences in the number of obtained unique clones from each library. However, severe reduction in sequence diversity was observed in p3-Fab libraries prior to panning, which in turn, materialized as a low number of unique specific clones. Oligovalent display by hyperphage resulted in a higher number of unique clones, but the same highest affinity anti-DIG Fab was recovered also by VCS-M13 superinfection. The compromised enrichment of the target-specific clones from the Fab repertoire as a fusion to p9 capsid protein in our experiments, the significant loss of functional diversity in Fab-p3 library after single phage packing cycle and the retrieval of higher affinity anti-digoxigenin clones as ScFv molecules than as Fab molecules from the same source repertoire indicate that the chosen display format may have a significant impact on the selection outcome. This study demonstrates that in addition to library content, also display related issues, should be taken into consideration when planning directed evolution experiments.
NASA Technical Reports Server (NTRS)
Norgard, John D.
2012-01-01
For future NASA Manned Space Exploration of the Moon and Mars, a blunt body capsule, called the Orion Crew Exploration Vehicle (CEV), composed of a Crew Module (CM) and a Service Module (SM), with a parachute decent assembly is planned for reentry back to Earth. A Capsule Parachute Assembly System (CPAS) is being developed for preliminary prototype parachute drop tests at the Yuma Proving Ground (YPG) to simulate high-speed reentry to Earth from beyond Low-Earth-Orbit (LEO) and to provide measurements of position, velocity, acceleration, attitude, temperature, pressure, humidity, and parachute loads. The primary and secondary (backup) avionics systems on CPAS also provide mission critical firing events to deploy, reef, and release the parachutes in three stages (extraction, drogues, mains) using mortars and pressure cartridge assemblies. In addition, a Mid-Air Delivery System (MDS) is used to separate the capsule from the sled that is used to eject the capsule from the back of the drop plane. Also, high-speed and high-definition cameras in a Video Camera System (VCS) are used to film the drop plane extraction and parachute landing events. Intentional and unintentional radiation emitted from and received by antennas and electronic devices on/in the CEV capsule, the MDS sled, and the VCS system are being tested for radiated emissions/immunity (susceptibility) (RE/RS). To verify Electromagnetic Compatibility (EMC) of the Orion capsule, Electromagnetic Interference (EMI) measurements are being made inside a semi-anechoic chamber at NASA/JSC on the components of the CPAS system. Measurements are made at 1m from the components-under-test (CUT). In addition, EMI measurements of the integrated CEV system are being made inside a hanger at YPG. These measurements are made in a complete circle, at 30? angles or less, around the Orion Capsule, the spacecraft system under-test (SUT). Near-field B-Dot probe measurements on the surface of the Orion capsule are being extrapolated outward to the 1m standard distance for comparison to the MIL-STD radiated emissions limit, and far-field hybrid antenna measurements at 3m are being extrapolated inward to the 1m distance for similar comparisons.
Kazmierczak, Philipp M; Rominger, Axel; Wenter, Vera; Spitzweg, Christine; Auernhammer, Christoph; Angele, Martin K; Rist, Carsten; Cyran, Clemens C
2017-04-01
To quantify the additional value of 68 Ga-DOTA-TATE PET/CT in comparison with contrast-enhanced CT alone for primary tumour detection in neuroendocrine cancer of unknown primary (CUP-NET). In total, 38 consecutive patients (27 men, 11 women; mean age 62 years) with histologically proven CUP-NET who underwent a contrast-enhanced 68 Ga-DOTA-TATE PET/CT scan for primary tumour detection and staging between 2010 and 2014 were included in this IRB-approved retrospective study. Two blinded readers independently analysed the contrast-enhanced CT and 68 Ga-DOTA-TATE PET datasets separately and noted from which modality they suspected a primary tumour. Consensus was reached if the results were divergent. Postoperative histopathology (24 patients) and follow-up 68 Ga-DOTA-TATE PET/CT imaging (14 patients) served as the reference standards and statistical measures of diagnostic accuracy were calculated accordingly. The majority of confirmed primary tumours were located in the abdomen (ileum in 19 patients, pancreas in 12, lung in 2, small pelvis in 1). High interobserver agreement was noted regarding the suspected primary tumour site (Cohen's k 0.90, p < 0.001). 68 Ga-DOTA-TATE PET demonstrated a significantly higher sensitivity (94 % vs. 63 %, p = 0.005) and a significantly higher accuracy (87 % vs. 68 %, p = 0.003) than contrast-enhanced CT. Ga-DOTA-TATE PET/CT compared with contrast-enhanced CT alone provides an improvement in sensitivity of 50 % and an improvement in accuracy of 30 % in primary tumour detection in CUP-NET. • 68 Ga-DOTA-TATE PET augments the sensitivity of contrast-enhanced CT by 50 % • 68 Ga-DOTA-TATE PET augments the accuracy of contrast-enhanced CT by 30 % • Somatostatin receptor-targeted hybrid imaging optimizes primary tumour detection in CUP-NET.
Ultrasonography for endoleak detection after endoluminal abdominal aortic aneurysm repair.
Abraha, Iosief; Luchetta, Maria Laura; De Florio, Rita; Cozzolino, Francesco; Casazza, Giovanni; Duca, Piergiorgio; Parente, Basso; Orso, Massimiliano; Germani, Antonella; Eusebi, Paolo; Montedori, Alessandro
2017-06-09
People with abdominal aortic aneurysm who receive endovascular aneurysm repair (EVAR) need lifetime surveillance to detect potential endoleaks. Endoleak is defined as persistent blood flow within the aneurysm sac following EVAR. Computed tomography (CT) angiography is considered the reference standard for endoleak surveillance. Colour duplex ultrasound (CDUS) and contrast-enhanced CDUS (CE-CDUS) are less invasive but considered less accurate than CT. To determine the diagnostic accuracy of colour duplex ultrasound (CDUS) and contrast-enhanced-colour duplex ultrasound (CE-CDUS) in terms of sensitivity and specificity for endoleak detection after endoluminal abdominal aortic aneurysm repair (EVAR). We searched MEDLINE, Embase, LILACS, ISI Conference Proceedings, Zetoc, and trial registries in June 2016 without language restrictions and without use of filters to maximize sensitivity. Any cross-sectional diagnostic study evaluating participants who received EVAR by both ultrasound (with or without contrast) and CT scan assessed at regular intervals. Two pairs of review authors independently extracted data and assessed quality of included studies using the QUADAS 1 tool. A third review author resolved discrepancies. The unit of analysis was number of participants for the primary analysis and number of scans performed for the secondary analysis. We carried out a meta-analysis to estimate sensitivity and specificity of CDUS or CE-CDUS using a bivariate model. We analysed each index test separately. As potential sources of heterogeneity, we explored year of publication, characteristics of included participants (age and gender), direction of the study (retrospective, prospective), country of origin, number of CDUS operators, and ultrasound manufacturer. We identified 42 primary studies with 4220 participants. Twenty studies provided accuracy data based on the number of individual participants (seven of which provided data with and without the use of contrast). Sixteen of these studies evaluated the accuracy of CDUS. These studies were generally of moderate to low quality: only three studies fulfilled all the QUADAS items; in six (40%) of the studies, the delay between the tests was unclear or longer than four weeks; in eight (50%), the blinding of either the index test or the reference standard was not clearly reported or was not performed; and in two studies (12%), the interpretation of the reference standard was not clearly reported. Eleven studies evaluated the accuracy of CE-CDUS. These studies were of better quality than the CDUS studies: five (45%) studies fulfilled all the QUADAS items; four (36%) did not report clearly the blinding interpretation of the reference standard; and two (18%) did not clearly report the delay between the two tests.Based on the bivariate model, the summary estimates for CDUS were 0.82 (95% confidence interval (CI) 0.66 to 0.91) for sensitivity and 0.93 (95% CI 0.87 to 0.96) for specificity whereas for CE-CDUS the estimates were 0.94 (95% CI 0.85 to 0.98) for sensitivity and 0.95 (95% CI 0.90 to 0.98) for specificity. Regression analysis showed that CE-CDUS was superior to CDUS in terms of sensitivity (LR Chi 2 = 5.08, 1 degree of freedom (df); P = 0.0242 for model improvement).Seven studies provided estimates before and after administration of contrast. Sensitivity before contrast was 0.67 (95% CI 0.47 to 0.83) and after contrast was 0.97 (95% CI 0.92 to 0.99). The improvement in sensitivity with of contrast use was statistically significant (LR Chi 2 = 13.47, 1 df; P = 0.0002 for model improvement).Regression testing showed evidence of statistically significant effect bias related to year of publication and study quality within individual participants based CDUS studies. Sensitivity estimates were higher in the studies published before 2006 than the estimates obtained from studies published in 2006 or later (P < 0.001); and studies judged as low/unclear quality provided higher estimates in sensitivity. When regression testing was applied to the individual based CE-CDUS studies, none of the items, namely direction of the study design, quality, and age, were identified as a source of heterogeneity.Twenty-two studies provided accuracy data based on number of scans performed (of which four provided data with and without the use of contrast). Analysis of the studies that provided scan based data showed similar results. Summary estimates for CDUS (18 studies) showed 0.72 (95% CI 0.55 to 0.85) for sensitivity and 0.95 (95% CI 0.90 to 0.96) for specificity whereas summary estimates for CE-CDUS (eight studies) were 0.91 (95% CI 0.68 to 0.98) for sensitivity and 0.89 (95% CI 0.71 to 0.96) for specificity. This review demonstrates that both ultrasound modalities (with or without contrast) showed high specificity. For ruling in endoleaks, CE-CDUS appears superior to CDUS. In an endoleak surveillance programme CE-CDUS can be introduced as a routine diagnostic modality followed by CT scan only when the ultrasound is positive to establish the type of endoleak and the subsequent therapeutic management.
Potential Cost Savings of Contrast-Enhanced Digital Mammography.
Patel, Bhavika K; Gray, Richard J; Pockaj, Barbara A
2017-06-01
The purpose of this article is to discuss whether the sensitivity and specificity of contrast-enhanced digital mammography (CEDM) render it a viable diagnostic alternative to breast MRI. That CEDM couples low-energy images (comparable to the diagnostic quality of standard mammography) and subtracted contrast-enhanced mammograms make it a cost-effective modality and a realistic substitute for the more costly breast MRI.
Sensitivity to Rhythmic Parameters in Dyslexic Children: A Comparison of Hungarian and English
ERIC Educational Resources Information Center
Suranyi, Zsuzsanna; Csepe, Valeria; Richardson, Ulla; Thomson, Jennifer M.; Honbolygo, Ferenc; Goswami, Usha
2009-01-01
It has been proposed that sensitivity to the parameters underlying speech rhythm may be important in setting up well-specified phonological representations in the mental lexicon. However, different acoustic parameters may contribute differentially to rhythm and stress in different languages. Here we contrast sensitivity to one such cue, amplitude…
NASA Astrophysics Data System (ADS)
Zhang, Guojun; Ding, Junwen; Xu, Wei; Liu, Yuan; Wang, Renxin; Han, Janjun; Bai, Bing; Xue, Chenyang; Liu, Jun; Zhang, Wendong
2018-05-01
A micro hydrophone based on piezoresistive effect, "MEMS vector hydrophone" was developed for acoustic detection application. To improve the sensitivity of MEMS vector hydrophone at low frequency, we reported a stress centralized MEMS vector hydrophone (SCVH) mainly used in 20-500 Hz. Stress concentration area was actualized in sensitive unit of hydrophone by silicon micromachining technology. Then piezoresistors were placed in stress concentration area for better mechanical response, thereby obtaining higher sensitivity. Static analysis was done to compare the mechanical response of three different sensitive microstructure: SCVH, conventional micro-silicon four-beam vector hydrophone (CFVH) and Lollipop-shaped vector hydrophone (LVH) respectively. And fluid-structure interaction (FSI) was used to analyze the natural frequency of SCVH for ensuring the measurable bandwidth. Eventually, the calibration experiment in standing wave field was done to test the property of SCVH and verify the accuracy of simulation. The results show that the sensitivity of SCVH has nearly increased by 17.2 dB in contrast to CFVH and 7.6 dB in contrast to LVH during 20-500 Hz.
Vande Velde, G; Rangarajan, J R; Toelen, J; Dresselaers, T; Ibrahimi, A; Krylychkina, O; Vreys, R; Van der Linden, A; Maes, F; Debyser, Z; Himmelreich, U; Baekelandt, V
2011-06-01
The development of in vivo imaging protocols to reliably track transplanted cells or to report on gene expression is critical for treatment monitoring in (pre)clinical cell and gene therapy protocols. Therefore, we evaluated the potential of lentiviral vectors (LVs) and adeno-associated viral vectors (AAVs) to express the magnetic resonance imaging (MRI) reporter gene ferritin in the rodent brain. First, we compared the induction of background MRI contrast for both vector systems in immune-deficient and immune-competent mice. LV injection resulted in hypointense (that is, dark) changes of T(2)/T(2)(*) (spin-spin relaxation time)-weighted MRI contrast at the injection site, which can be partially explained by an inflammatory response against the vector injection. In contrast to LVs, AAV injection resulted in reduced background contrast. Moreover, AAV-mediated ferritin overexpression resulted in significantly enhanced contrast to background on T(2)(*)-weighted MRI. Although sensitivity associated with the ferritin reporter remains modest, AAVs seem to be the most promising vector system for in vivo MRI reporter gene imaging.
Rubin, G S; West, S K; Muñoz, B; Bandeen-Roche, K; Zeger, S; Schein, O; Fried, L P
1997-03-01
The Salisbury Eye Evaluation Project is a longitudinal study of risk factors for age-related eye diseases and the impact of eye disease and visual impairment on physical disability. In this article, the authors report the prevalence of visual impairment in their population and explore the relations among the various measures of visual function. A population-based sample of 2520 residents of Salisbury, Maryland, between the ages of 65 and 84 years were enrolled in the study. Twenty-six percent of participants were black. Vision tests included best-corrected Early Treatment Diabetic Retinopathy Study acuity, Pelli-Robson contrast sensitivity with and without glare, Randot stereoacuity, and 60 degrees Humphrey visual fields. Visual function decreased linearly with age for the acuity, contrast sensitivity, glare, and visual field tests. Stereoacuity remained constant into the mid-70s and declined at an accelerating rate thereafter. Black participants had lower contrast sensitivity, reduced stereoacuity, and worse visual fields, at all ages compared to white participants; however, white participants were more sensitive to glare. The overall prevalence of visual acuity impairment in blacks was 5.6% versus 3.0% for whites, using the traditional United States definition (worse than 20/40 to better than 20/200) and 3.3% for blacks versus 1.6% for whites, using the World Health Organization definition (worse than 20/60 to 20/400). Acuity was correlated moderately with contrast sensitivity, stereoacuity, and visual fields (Spearman rho = 0.50, 0.35, and 0.34, respectively). The correlation between acuity and glare sensitivity was low (rho = 0.12). Many aspects of visual function, not just acuity, decline with age. Black participants have more visual impairement than do white participants for all tests except glare sensitivity. The prevalence of visual acuity impairement in the Salisbury Eye Evaluation population is lower than that reported by other studies using similar test procedures. Low-to-moderate correlations among vision test scores suggest that several different dimensions of visual function are being assessed.
Di Leo, Giovanni; Fisci, Erica; Secchi, Francesco; Alì, Marco; Ambrogi, Federico; Sconfienza, Luca Maria; Sardanelli, Francesco
2016-10-01
To review the diagnostic performance of MR coronary angiography (MRCA) for coronary artery disease (CAD). Two independent reviewers searched on MEDLINE/EMBASE with the following inclusion criteria: 01/01/2000-03/23/2015 publication date; per-patient sensitivity/specificity for >50 % stenosis confirmed by conventional coronary angiography with raw data provided or retrievable; sample size >10. Quality was appraised using QUADAS2. Nine hundred eighteen studies were retrieved, 24 of them, including 1,638 patients, were selected. Using a bivariate model, the pooled sensitivity was 89 % (95 % confidence interval 86-92 %), the pooled specificity 72 % (63-79 %). Meta-regression did not show a significant impact on sensitivity/specificity for both year of publication and disease prevalence (p ≥ 0.114). Sensitivity of contrast-enhanced examinations (95 %, 90-97 %) was higher (p = 0.005) than that of unenhanced examinations (87 %, 83-90 %). Specificity of whole-heart acquisition mode (78 %, 72-84 %) was higher (p = 0.006) than that of targeted mode (57 %, 45-69 %). Specificity at 3 T (83 %, 69-92 %) was higher (p = 0.067) than that at 1.5 T (68 %, 60-76 %). Risk of bias and concerns regarding applicability were low. Sensitivity and specificity of MRCA for CAD were 89 % and 72 %, respectively. A specificity higher than 80 % may be obtained at 3 T. Whole-heart contrast-enhanced protocols should be preferred for a higher diagnostic performance. • MRCA sensitivity and specificity for CAD are below those of CTA. • Contrast administration increased sensitivity to 95 % (90-97 %), comparable with that of CTA. • Whole-heart mode increased specificity to 78 % (72-84 %), comparable with that of CTA. • Specificity at 3 T was borderline-significantly higher (p = 0.067) than at 1.5 T. • Whole-heart contrast-enhanced protocols are the best approach for MRCA.
High-contrast grating resonators for label-free detection of disease biomarkers
Sun, Tianbo; Kan, Shu; Marriott, Gerard; Chang-Hasnain, Connie
2016-01-01
A label-free optical biosensor is described that employs a silicon-based high-contrast grating (HCG) resonator with a spectral linewidth of ~500 pm that is sensitive to ligand-induced changes in surface properties. The device is used to generate thermodynamic and kinetic data on surface-attached antibodies with their respective antigens. The device can detect serum cardiac troponin I, a biomarker of cardiac disease to 100 pg/ml within 4 mins, which is faster, and as sensitive as current enzyme-linked immuno-assays for cTnI. PMID:27265624
High-contrast grating resonators for label-free detection of disease biomarkers
NASA Astrophysics Data System (ADS)
Sun, Tianbo; Kan, Shu; Marriott, Gerard; Chang-Hasnain, Connie
2016-06-01
A label-free optical biosensor is described that employs a silicon-based high-contrast grating (HCG) resonator with a spectral linewidth of ~500 pm that is sensitive to ligand-induced changes in surface properties. The device is used to generate thermodynamic and kinetic data on surface-attached antibodies with their respective antigens. The device can detect serum cardiac troponin I, a biomarker of cardiac disease to 100 pg/ml within 4 mins, which is faster, and as sensitive as current enzyme-linked immuno-assays for cTnI.
Visual Multipoles And The Assessment Of Visual Sensitivity To Displayed Images
NASA Astrophysics Data System (ADS)
Klein, Stanley A.
1989-08-01
The contrast sensitivity function (CSF) is widely used to specify the sensitivity of the visual system. Each point of the CSF specifies the amount of contrast needed to detect a sinusoidal grating of a given spatial frequency. This paper describes a set of five mathematically related visual patterns, called "multipoles," that should replace the CSF for measuring visual performance. The five patterns (ramp, edge, line, dipole and quadrupole) are localized in space rather than being spread out as sinusoidal gratings. The multipole sensitivity of the visual system provides an alternative characterization that complements the CSF in addition to offering several advantages. This paper provides an overview of the properties and uses of the multipole stimuli. This paper is largely a summary of several unpublished manuscripts with excerpts from them. Derivations and full references are omitted here. Please write me if you would like the full manuscripts.
V1 mechanisms underlying chromatic contrast detection
Hass, Charles A.
2013-01-01
To elucidate the cortical mechanisms of color vision, we recorded from individual primary visual cortex (V1) neurons in macaque monkeys performing a chromatic detection task. Roughly 30% of the neurons that we encountered were unresponsive at the monkeys' psychophysical detection threshold (PT). The other 70% were responsive at threshold but on average, were slightly less sensitive than the monkey. For these neurons, the relationship between neurometric threshold (NT) and PT was consistent across the four isoluminant color directions tested. A corollary of this result is that NTs were roughly four times lower for stimuli that modulated the long- and middle-wavelength sensitive cones out of phase. Nearly one-half of the neurons that responded to chromatic stimuli at the monkeys' detection threshold also responded to high-contrast luminance modulations, suggesting a role for neurons that are jointly tuned to color and luminance in chromatic detection. Analysis of neuronal contrast-response functions and signal-to-noise ratios yielded no evidence for a special set of “cardinal color directions,” for which V1 neurons are particularly sensitive. We conclude that at detection threshold—as shown previously with high-contrast stimuli—V1 neurons are tuned for a diverse set of color directions and do not segregate naturally into red–green and blue–yellow categories. PMID:23446689
Visual detection following retinal damage: predictions of an inhomogeneous retino-cortical model
NASA Astrophysics Data System (ADS)
Arnow, Thomas L.; Geisler, Wilson S.
1996-04-01
A model of human visual detection performance has been developed, based on available anatomical and physiological data for the primate visual system. The inhomogeneous retino- cortical (IRC) model computes detection thresholds by comparing simulated neural responses to target patterns with responses to a uniform background of the same luminance. The model incorporates human ganglion cell sampling distributions; macaque monkey ganglion cell receptive field properties; macaque cortical cell contrast nonlinearities; and a optical decision rule based on ideal observer theory. Spatial receptive field properties of cortical neurons were not included. Two parameters were allowed to vary while minimizing the squared error between predicted and observed thresholds. One parameter was decision efficiency, the other was the relative strength of the ganglion-cell center and surround. The latter was only allowed to vary within a small range consistent with known physiology. Contrast sensitivity was measured for sinewave gratings as a function of spatial frequency, target size and eccentricity. Contrast sensitivity was also measured for an airplane target as a function of target size, with and without artificial scotomas. The results of these experiments, as well as contrast sensitivity data from the literature were compared to predictions of the IRC model. Predictions were reasonably good for grating and airplane targets.
Enhanced music sensitivity in 9-month-old bilingual infants.
Liu, Liquan; Kager, René
2017-02-01
This study explores the influence of bilingualism on the cognitive processing of language and music. Specifically, we investigate how infants learning a non-tone language perceive linguistic and musical pitch and how bilingualism affects cross-domain pitch perception. Dutch monolingual and bilingual infants of 8-9 months participated in the study. All infants had Dutch as one of the first languages. The other first languages, varying among bilingual families, were not tone or pitch accent languages. In two experiments, infants were tested on the discrimination of a lexical (N = 42) or a violin (N = 48) pitch contrast via a visual habituation paradigm. The two contrasts shared identical pitch contours but differed in timbre. Non-tone language learning infants did not discriminate the lexical contrast regardless of their ambient language environment. When perceiving the violin contrast, bilingual but not monolingual infants demonstrated robust discrimination. We attribute bilingual infants' heightened sensitivity in the musical domain to the enhanced acoustic sensitivity stemming from a bilingual environment. The distinct perceptual patterns between language and music and the influence of acoustic salience on perception suggest processing diversion and association in the first year of life. Results indicate that the perception of music may entail both shared neural network with language processing, and unique neural network that is distinct from other cognitive functions.
Jairo A. Diaz; Robert J. Moon; Jeffrey P. Youngblood
2014-01-01
Thermal expansion represents a vital indicator of the processing history and dimensional stability of materials. Solvent-sensitive, thin, and compliant samples are particularly challenging to test. Here we describe how textures highlighted by contrast enhanced optical microscopy modes (i.e., polarized light (PL), phase contrast (PC)) and bright field (BF) can be used...
Braun, Doris I; Schütz, Alexander C; Gegenfurtner, Karl R
2017-07-01
Visual sensitivity is dynamically modulated by eye movements. During saccadic eye movements, sensitivity is reduced selectively for low-spatial frequency luminance stimuli and largely unaffected for high-spatial frequency luminance and chromatic stimuli (Nature 371 (1994), 511-513). During smooth pursuit eye movements, sensitivity for low-spatial frequency luminance stimuli is moderately reduced while sensitivity for chromatic and high-spatial frequency luminance stimuli is even increased (Nature Neuroscience, 11 (2008), 1211-1216). Since these effects are at least partly of different polarity, we investigated the combined effects of saccades and smooth pursuit on visual sensitivity. For the time course of chromatic sensitivity, we found that detection rates increased slightly around pursuit onset. During saccades to static and moving targets, detection rates dropped briefly before the saccade and reached a minimum at saccade onset. This reduction of chromatic sensitivity was present whenever a saccade was executed and it was not modified by subsequent pursuit. We also measured contrast sensitivity for flashed high- and low-spatial frequency luminance and chromatic stimuli during saccades and pursuit. During saccades, the reduction of contrast sensitivity was strongest for low-spatial frequency luminance stimuli (about 90%). However, a significant reduction was also present for chromatic stimuli (about 58%). Chromatic sensitivity was increased during smooth pursuit (about 12%). These results suggest that the modulation of visual sensitivity during saccades and smooth pursuit is more complex than previously assumed. Copyright © 2017 Elsevier Ltd. All rights reserved.
Acoustic bubble sorting for ultrasound contrast agent enrichment.
Segers, Tim; Versluis, Michel
2014-05-21
An ultrasound contrast agent (UCA) suspension contains encapsulated microbubbles with a wide size distribution, with radii ranging from 1 to 10 μm. Medical transducers typically operate at a single frequency, therefore only a small selection of bubbles will resonate to the driving ultrasound pulse. Thus, the sensitivity can be improved by narrowing down the size distribution. Here, we present a simple lab-on-a-chip method to sort the population of microbubbles on-chip using a traveling ultrasound wave. First, we explore the physical parameter space of acoustic bubble sorting using well-defined bubble sizes formed in a flow-focusing device, then we demonstrate successful acoustic sorting of a commercial UCA. This novel sorting strategy may lead to an overall improvement of the sensitivity of contrast ultrasound by more than 10 dB.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peck, C. L.; Rast, M. P.
2015-08-01
Solar irradiance variations over solar rotational timescales are largely determined by the passage of magnetic structures across the visible solar disk. Variations on solar cycle timescales are thought to be similarly due to changes in surface magnetism with activity. Understanding the contribution of magnetic structures to total solar irradiance and solar spectral irradiance requires assessing their contributions as a function of disk position. Since only relative photometry is possible from the ground, the contrasts of image pixels are measured with respect to a center-to-limb intensity profile. Using nine years of full-disk red and blue continuum images from the Precision Solarmore » Photometric Telescope at the Mauna Loa Solar Observatory, we examine the sensitivity of continuum contrast measurements to the center-to-limb profile definition. Profiles which differ only by the amount of magnetic activity allowed in the pixels used to determine them yield oppositely signed solar cycle length continuum contrast trends, either agreeing with previous results and showing negative correlation with solar cycle or disagreeing and showing positive correlation with solar cycle. Changes in the center-to-limb profile shape over the solar cycle are responsible for the contradictory contrast results, and we demonstrate that the lowest contrast structures, internetwork and network, are most sensitive to these. Thus the strengths of the full-disk, internetwork, and network photometric trends depend critically on the magnetic flux density used in the quiet-Sun definition. We conclude that the contributions of low contrast magnetic structures to variations in the solar continuum output, particularly to long-term variations, are difficult, if not impossible, to determine without the use of radiometric imaging.« less
Miri, Shimasadat; Mehralizadeh, Sandra; Sadri, Donya; Motamedi, Mahmood Reza Kalantar
2015-01-01
Purpose This study evaluated the diagnostic accuracy of the reverse contrast mode in intraoral digital radiography for the detection of proximal dentinal caries, in comparison with the original digital radiographs. Materials and Methods Eighty extracted premolars with no clinically apparent caries were selected, and digital radiographs of them were taken separately in standard conditions. Four observers examined the original radiographs and the same radiographs in the reverse contrast mode with the goal of identifying proximal dentinal caries. Microscopic sections 5 µm in thickness were prepared from the teeth in the mesiodistal direction. Four slides prepared from each sample used as the diagnostic gold standard. The data were analyzed using SPSS (α=0.05). Results Our results showed that the original radiographs in order to identify proximal dentinal caries had the following values for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy, respectively: 72.5%, 90%, 87.2%, 76.5%, and 80.9%. For the reverse contrast mode, however, the corresponding values were 63.1%, 89.4%, 87.1%, 73.5%, and 78.8%, respectively. The sensitivity of original digital radiograph for detecting proximal dentinal caries was significantly higher than that of reverse contrast mode (p<0.05). However, no statistically significant differences were found regarding specificity, positive predictive value, negative predictive value, or accuracy (p>0.05). Conclusion The sensitivity of the original digital radiograph for detecting proximal dentinal caries was significantly higher than that of the reversed contrast images. However, no statistically significant differences were found between these techniques regarding specificity, positive predictive value, negative predictive value, or accuracy. PMID:26389055
Computer-aided detection of bladder mass within non-contrast-enhanced region of CT Urography (CTU)
NASA Astrophysics Data System (ADS)
Cha, Kenny H.; Hadjiiski, Lubomir M.; Chan, Heang-Ping; Caoili, Elaine M.; Cohan, Richard H.; Weizer, Alon; Zhou, Chuan
2016-03-01
We are developing a computer-aided detection system for bladder cancer in CT urography (CTU). We have previously developed methods for detection of bladder masses within the contrast-enhanced region of the bladder. In this study, we investigated methods for detection of bladder masses within the non-contrast enhanced region. The bladder was first segmented using a newly developed deep-learning convolutional neural network in combination with level sets. The non-contrast-enhanced region was separated from the contrast-enhanced region with a maximum-intensityprojection- based method. The non-contrast region was smoothed and a gray level threshold was employed to segment the bladder wall and potential masses. The bladder wall was transformed into a straightened thickness profile, which was analyzed to identify lesion candidates as a prescreening step. The lesion candidates were segmented using our autoinitialized cascaded level set (AI-CALS) segmentation method, and 27 morphological features were extracted for each candidate. Stepwise feature selection with simplex optimization and leave-one-case-out resampling were used for training and validation of a false positive (FP) classifier. In each leave-one-case-out cycle, features were selected from the training cases and a linear discriminant analysis (LDA) classifier was designed to merge the selected features into a single score for classification of the left-out test case. A data set of 33 cases with 42 biopsy-proven lesions in the noncontrast enhanced region was collected. During prescreening, the system obtained 83.3% sensitivity at an average of 2.4 FPs/case. After feature extraction and FP reduction by LDA, the system achieved 81.0% sensitivity at 2.0 FPs/case, and 73.8% sensitivity at 1.5 FPs/case.
Contrast Transmission In Medical Image Display
NASA Astrophysics Data System (ADS)
Pizer, Stephen M.; Zimmerman, John B.; Johnston, R. Eugene
1982-11-01
The display of medical images involves transforming recorded intensities such at CT numbers into perceivable intensities such as combinations of color and luminance. For the viewer to extract the most information about patterns of decreasing and increasing recorded intensity, the display designer must pay attention to three issues: 1) choice of display scale, including its discretization; 2) correction for variations in contrast sensitivity across the display scale due to the observer and the display device (producing an honest display); and 3) contrast enhancement based on the information in the recorded image and its importance, determined by viewing objectives. This paper will present concepts and approaches in all three of these areas. In choosing display scales three properties are important: sensitivity, associability, and naturalness of order. The unit of just noticeable difference (jnd) will be carefully defined. An observer experiment to measure the jnd values across a display scale will be specified. The overall sensitivity provided by a scale as measured in jnd's gives a measure of sensitivity called the perceived dynamic range (PDR). Methods for determining the PDR fran the aforementioned PDR values, and PDR's for various grey and pseudocolor scales will be presented. Methods of achieving sensitivity while retaining associability and naturalness of order with pseudocolor scales will be suggested. For any display device and scale it is useful to compensate for the device and observer by preceding the device with an intensity mapping (lookup table) chosen so that perceived intensity is linear with display-driving intensity. This mapping can be determined from the aforementioned jnd values. With a linearized display it is possible to standardize display devices so that the same image displayed on different devices or scales (e.g. video and hard copy) will be in sane sense perceptually equivalent. Furthermore, with a linearized display, it is possible to design contrast enhancement mappings that optimize the transmission of information from the recorded image to the display-driving signal with the assurance that this information will not then be lost by a -further nonlinear relation between display-driving and perceived intensity. It is suggested that optimal contrast enhancement mappings are adaptive to the local distribution of recorded intensities.
NASA Astrophysics Data System (ADS)
Comastri, S. A.; Martin, G.; Simon, J. M.; Angarano, C.; Dominguez, S.; Luzzi, F.; Lanusse, M.; Ranieri, M. V.; Boccio, C. M.
2008-04-01
In Optometry and in Audiology, the routine tests to prescribe correction lenses and headsets are respectively the visual acuity test (the first chart with letters was developed by Snellen in 1862) and conventional pure tone audiometry (the first audiometer with electrical current was devised by Hartmann in 1878). At present there are psychophysical non invasive tests that, besides evaluating visual and auditory performance globally and even in cases catalogued as normal according to routine tests, supply early information regarding diseases such as diabetes, hypertension, renal failure, cardiovascular problems, etc. Concerning Optometry, one of these tests is the achromatic luminance contrast sensitivity test (introduced by Schade in 1956). Concerning Audiology, one of these tests is high frequency pure tone audiometry (introduced a few decades ago) which yields information relative to pathologies affecting the basal cochlea and complements data resulting from conventional audiometry. These utilities of the contrast sensitivity test and of pure tone audiometry derive from the facts that Fourier components constitute the basis to synthesize stimuli present at the entrance of the visual and auditory systems; that these systems responses depend on frequencies and that the patient's psychophysical state affects frequency processing. The frequency of interest in the former test is the effective spatial frequency (inverse of the angle subtended at the eye by a cycle of a sinusoidal grating and measured in cycles/degree) and, in the latter, the temporal frequency (measured in cycles/sec). Both tests have similar duration and consist in determining the patient's threshold (corresponding to the inverse multiplicative of the contrast or to the inverse additive of the sound intensity level) for each harmonic stimulus present at the system entrance (sinusoidal grating or pure tone sound). In this article the frequencies, standard normality curves and abnormal threshold shifts inherent to the contrast sensitivity test (which for simplicity could be termed "visionmetry") and to pure tone audiometry (also termed auditory sensitivity test) are analyzed with the purpose of contributing to divulge their ability to supply early information associated to pathologies not solely related to the visual and auditory systems respectively.
Ghadiri, H; Ay, M R; Shiran, M B; Soltanian-Zadeh, H
2013-01-01
Objective: Recently introduced energy-sensitive X-ray CT makes it feasible to discriminate different nanoparticulate contrast materials. The purpose of this work is to present a K-edge ratio method for differentiating multiple simultaneous contrast agents using spectral CT. Methods: The ratio of two images relevant to energy bins straddling the K-edge of the materials is calculated using an analytic CT simulator. In the resulting parametric map, the selected contrast agent regions can be identified using a thresholding algorithm. The K-edge ratio algorithm is applied to spectral images of simulated phantoms to identify and differentiate up to four simultaneous and targeted CT contrast agents. Results: We show that different combinations of simultaneous CT contrast agents can be identified by the proposed K-edge ratio method when energy-sensitive CT is used. In the K-edge parametric maps, the pixel values for biological tissues and contrast agents reach a maximum of 0.95, whereas for the selected contrast agents, the pixel values are larger than 1.10. The number of contrast agents that can be discriminated is limited owing to photon starvation. For reliable material discrimination, minimum photon counts corresponding to 140 kVp, 100 mAs and 5-mm slice thickness must be used. Conclusion: The proposed K-edge ratio method is a straightforward and fast method for identification and discrimination of multiple simultaneous CT contrast agents. Advances in knowledge: A new spectral CT-based algorithm is proposed which provides a new concept of molecular CT imaging by non-iteratively identifying multiple contrast agents when they are simultaneously targeting different organs. PMID:23934964
Daikoku, Tohru; Oyama, Yukari; Yajima, Misako; Sekizuka, Tsuyoshi; Kuroda, Makoto; Shimada, Yuka; Takehara, Kazuhiko; Miwa, Naoko; Okuda, Tomoko; Sata, Tetsutaro; Shiraki, Kimiyasu
2015-06-01
Herpes simplex virus 2 caused a genital ulcer, and a secondary herpetic whitlow appeared during acyclovir therapy. The secondary and recurrent whitlow isolates were acyclovir-resistant and temperature-sensitive in contrast to a genital isolate. We identified the ribonucleotide reductase mutation responsible for temperature-sensitivity by deep-sequencing analysis.
NASA Astrophysics Data System (ADS)
Zwick, Harry; Ness, James W.; Loveday, J.; Molchany, Jerome W.; Stuck, Bruce E.
1997-05-01
Laser induced damage to the retina may produce immediate and serious loss in visual acuity as well as subsequent recovery of visual acuity over a 1 to 6 month post exposure period. While acuity may recover, full utilization of the foveal region may not return. In one patient, a superior/temporal preferred retinal location (PRL) was apparent, while a second patient demonstrated significant foveal involvement and contrast sensitivity more reflective of foveal than parafoveal involvement. These conditions of injury wee simulated by using an artificial scotoma technique which optically stabilized a 5 degree opacity in the center of the visual field. The transmission of spatially degraded target information in the scotoma was 0 percent, 5 percent and 95 percent. Contrast sensitivity for the 0 percent and 5 percent transmission scotoma showed broad spatial frequency suppression as opposed to a bipartite contrast sensitivity function with a narrow sensitivity loss at 3 cycles/degree for the 95 percent transmission scotoma. A PRL shift to superior temporal retina with a concomitant change in accommodation was noted as target resolution became more demanding. These findings suggest that restoration of visual acuity in human laser accidents may depend upon the functionality of complex retinal and cortical adaptive mechanisms.
Rand, Danielle; Derdak, Zoltan; Carlson, Rolf; ...
2015-10-29
Hepatocellular carcinoma (HCC) is one of the most common malignant tumors worldwide and is almost uniformly fatal. Current methods of detection include ultrasound examination and imaging by CT scan or MRI; however, these techniques are problematic in terms of sensitivity and specificity, and the detection of early tumors (<1 cm diameter) has proven elusive. Better, more specific, and more sensitive detection methods are therefore urgently needed. Here we discuss the application of a newly developed x-ray imaging technique called Spatial Frequency Heterodyne Imaging (SFHI) for the early detection of HCC. SFHI uses x-rays scattered by an object to form anmore » image and is more sensitive than conventional absorption-based x-radiography. We show that tissues labeled in vivo with gold nanoparticle contrast agents can be detected using SFHI. We also demonstrate that directed targeting and SFHI of HCC tumors in a mouse model is possible through the use of HCC-specific antibodies. As a result, the enhanced sensitivity of SFHI relative to currently available techniques enables the x-ray imaging of tumors that are just a few millimeters in diameter and substantially reduces the amount of nanoparticle contrast agent required for intravenous injection relative to absorption-based x-ray imaging.« less
Luo, Furong; Bao, Xuan; Qin, Yingyan; Hou, Min; Wu, Mingxing
2018-06-01
To evaluate the long-term effect of glistenings and surface light scattering of intraocular lenses (IOLs) on visual and optical performance after cataract surgery. Pseudophakic eyes that underwent standard phacoemulsification and two types of hydrophobic acrylic spherical IOL implantation without complications for at least 5 years were included in this retrospective study. Participants were divided into the glistenings, surface light scattering, and control groups according to the current condition of the IOLs. Then participants received a follow-up examination including uncorrected and corrected distance visual acuity (UDVA and CDVA), contrast sensitivity, straylight, and intraocular higher order aberrations, as well as point spread function (PSF) and modulation transfer function (MTF). A total of 140 eyes were included in the study. UDVA, CDVA, and glare sensitivity were not significantly different among the three groups (P > .05). However, compared with the control group, the IOLs of the glistenings and surface light scattering groups were associated with significantly lower contrast sensitivity under no glare conditions. Furthermore, eye with glistenings exhibited the highest straylight value (P < .05), whereas no difference was found between the surface light scattering and control groups. In contrast to the control group, the spherical aberration increased and the mean values of PSF and MTF decreased in the glistenings and surface light scattering groups. Both glistenings and surface light scattering tend to impair subjective visual performance, such as contrast sensitivity, and potentially affect objective optical quality, including straylight, spherical aberration, PSF, and MTF. [J Refract Surg. 2018;34(6):372-378.]. Copyright 2018, SLACK Incorporated.
Sekundo, Walter; Gertnere, Jana; Bertelmann, Thomas; Solomatin, Igor
2014-05-01
To report one year results of the first cohort of routine refractive lenticule extraction through a small incision (ReLEx SMILE) for correction of myopia and myopic astigmatism. Fifty-four eyes of 27 patients with spherical equivalent of -4.68 ± 1.29D who underwent routine ReLEx SMILE by a single surgeon were prospectively followed-up for 1 year. We used the VisuMax femtosecond laser system (Carl Zeiss Meditec AG, Germany) with a 500 kHz repetition rate. Folow-up intervals were at 1 day, 1 week, 1, 3, 6, and 12 months after surgery. We obtained following parameters: uncorrected (UDVA) and distance-corrected visual acuity (CDVA), contrast sensitivity, and wave front measurements. We also recorded all complications. Because of suction loss in one eye, 12-month results were obtained in 53 eyes as follows. After 1 year, 88% of eyes with plano target had an UDVA of 20/20 or better. Twelve percent of eyes lost 1 line of CDVA, while 31% gained 1 line and 3% gained 2 lines. The mean SE after 1 year was -0.19 ± 0.19. The mean refraction change between month 1 and 12 was 0.08 D. Neither mesopic nor photopic contrast sensitivity showed any significant changes. The high-order aberrations (HOA) increased from 0.17 to 0.27 μm (Malacara notation). No visually threatening complications were observed. In this first cohort, ReLEx SMILE produced satisfactory refractive outcomes with moderate induction of HOA and unaffected contrast sensitivity after 1 year.
Vomweg, T W; Buscema, M; Kauczor, H U; Teifke, A; Intraligi, M; Terzi, S; Heussel, C P; Achenbach, T; Rieker, O; Mayer, D; Thelen, M
2003-09-01
The aim of this study was to evaluate the capability of improved artificial neural networks (ANN) and additional novel training methods in distinguishing between benign and malignant breast lesions in contrast-enhanced magnetic resonance-mammography (MRM). A total of 604 histologically proven cases of contrast-enhanced lesions of the female breast at MRI were analyzed. Morphological, dynamic and clinical parameters were collected and stored in a database. The data set was divided into several groups using random or experimental methods [Training & Testing (T&T) algorithm] to train and test different ANNs. An additional novel computer program for input variable selection was applied. Sensitivity and specificity were calculated and compared with a statistical method and an expert radiologist. After optimization of the distribution of cases among the training and testing sets by the T & T algorithm and the reduction of input variables by the Input Selection procedure a highly sophisticated ANN achieved a sensitivity of 93.6% and a specificity of 91.9% in predicting malignancy of lesions within an independent prediction sample set. The best statistical method reached a sensitivity of 90.5% and a specificity of 68.9%. An expert radiologist performed better than the statistical method but worse than the ANN (sensitivity 92.1%, specificity 85.6%). Features extracted out of dynamic contrast-enhanced MRM and additional clinical data can be successfully analyzed by advanced ANNs. The quality of the resulting network strongly depends on the training methods, which are improved by the use of novel training tools. The best results of an improved ANN outperform expert radiologists.
Tao, Yuan; Jiang, Pengfei; Wei, Yuhua; Wang, Ping; Sun, Xiaoling; Wang, Hong
2016-11-01
Dry form of age-related macular degeneration (AMD) constitutes 90% of AMD cases, and it is characterized by the formation of drusen under the retina and the slow breakdown of the light-sensing cells in the macula, which causes a gradual loss of central vision. Since oxidative stress is involved in the pathogenesis of dry AMD, α-lipoic acid (LA) with antioxidant properties was selected, and its effect on anti-oxidative markers and visual quality in patients with dry AMD was assessed. A total of 100 dry AMD patients (60-83 years old) were randomly assigned to LA treatment group (n = 50) and placebo control group (n = 50). We measured the serum superoxide dismutase (SOD) activity, an important marker of antioxidant defense, best-corrected visual acuity (BCVA), contrast sensitivity, and Chinese-Version Low Vision Quality of Life (CLVQOL) before and after LA or placebo intervention. Pearson correlation coefficients were calculated to explore the relationship between contrast sensitivity values and CLVQOL scores. There was a statistically significant increase in serum SOD activity after LA intervention. The CLVQOL score was improved significantly after LA treatment. The contrast sensitivity measured at middle and low spatial frequency was significantly higher after LA treatment. CLVQOL scores were positively correlated with contrast sensitivity at low spatial frequency (3 cyc/degree) in LA-treated group. These results indicate that LA treatment improves vision-related quality of life in patients with dry AMD probably by increasing antioxidant activity. Thus, LA can be regarded as a promising agent for the treatment of AMD.
Visual functions and interocular interactions in anisometropic children with and without amblyopia.
Lai, Xin Jie; Alexander, Jack; He, Mingguang; Yang, Zhikuan; Suttle, Catherine
2011-08-29
In uncorrected anisometropia, protracted dichoptic stimulation may result in interocular inhibition, which may be a contributing factor in amblyopia development. This study investigates the relationship between interocular interactions and anisometropic amblyopia. Three visual functions (low-contrast acuity, contrast sensitivity, and alignment sensitivity) were measured in the nondominant eye of 44 children aged 5 to 11 years: 10 with normal vision, 17 with anisometropia without amblyopia, and 17 with anisometropic amblyopia. The dominant eye was either fully or partially occluded. The difference in nondominant eye visual function between the full-and partial-occlusion conditions was termed the interaction index. The index of each visual function was compared between subject groups. A higher index indicates stronger inhibition of nondominant eye function with partial occlusion of the dominant eye. Amblyopic children had 6 months of therapy (refractive correction and occlusion), and the reduction in interocular difference in high-contrast acuity was regarded as the treatment outcome. The relationships of the interaction index with the degree of anisometropia, the severity of amblyopia, and the treatment outcomes were examined. The acuity interaction index was significantly higher in anisometropic children with amblyopia than in those without (P = 0.003). It was positively correlated with the degree of anisometropia (r(s) = 0.35, P = 0.042) and the amblyopic treatment outcomes (r(s) = 0.54, P = 0.038). No such difference or association was found between the contrast sensitivity or alignment sensitivity interaction index and anisometropic amblyopia. Interocular interactions are associated with amblyopia, the degree of anisometropia, and amblyopia treatment outcomes, but these associations are visual function dependent.
Effects of eccentricity on color contrast.
Vanston, John E; Crognale, Michael A
2018-04-01
Using near-threshold stimuli, human color sensitivity has been shown to decrease across the visual field, likely due in part to physiological differences between the fovea and periphery. It remains unclear to what extent this holds true for suprathreshold stimuli. The current study used suprathreshold contrast matching to examine how perceived contrast varies with eccentricity along the cardinal axes in a cone-opponent space. Our data show that, despite increasing stimulus size in the periphery, the LM axis stimuli were still perceived as reduced in contrast, whereas the S axis perceived contrast was observed to increase with eccentricity.
Kieper, Douglas Arthur [Seattle, WA; Majewski, Stanislaw [Morgantown, WV; Welch, Benjamin L [Hampton, VA
2012-07-03
An improved method for enhancing the contrast between background and lesion areas of a breast undergoing dual-head scintimammographic examination comprising: 1) acquiring a pair of digital images from a pair of small FOV or mini gamma cameras compressing the breast under examination from opposing sides; 2) inverting one of the pair of images to align or co-register with the other of the images to obtain co-registered pixel values; 3) normalizing the pair of images pixel-by-pixel by dividing pixel values from each of the two acquired images and the co-registered image by the average count per pixel in the entire breast area of the corresponding detector; and 4) multiplying the number of counts in each pixel by the value obtained in step 3 to produce a normalization enhanced two dimensional contrast map. This enhanced (increased contrast) contrast map enhances the visibility of minor local increases (uptakes) of activity over the background and therefore improves lesion detection sensitivity, especially of small lesions.
Kieper, Douglas Arthur [Newport News, VA; Majewski, Stanislaw [Yorktown, VA; Welch, Benjamin L [Hampton, VA
2008-10-28
An improved method for enhancing the contrast between background and lesion areas of a breast undergoing dual-head scintimammographic examination comprising: 1) acquiring a pair of digital images from a pair of small FOV or mini gamma cameras compressing the breast under examination from opposing sides; 2) inverting one of the pair of images to align or co-register with the other of the images to obtain co-registered pixel values; 3) normalizing the pair of images pixel-by-pixel by dividing pixel values from each of the two acquired images and the co-registered image by the average count per pixel in the entire breast area of the corresponding detector; and 4) multiplying the number of counts in each pixel by the value obtained in step 3 to produce a normalization enhanced two dimensional contrast map. This enhanced (increased contrast) contrast map enhances the visibility of minor local increases (uptakes) of activity over the background and therefore improves lesion detection sensitivity, especially of small lesions.
Matheson, H E; Bilsbury, T G; McMullen, P A
2012-03-01
A large body of research suggests that faces are processed by a specialized mechanism within the human visual system. This specialized mechanism is made up of subprocesses (Maurer, LeGrand, & Mondloch, 2002). One subprocess, called second- order relational processing, analyzes the metric distances between face parts. Importantly, it is well established that other-race faces and contrast-reversed faces are associated with impaired performance on numerous face processing tasks. Here, we investigated the specificity of second-order relational processing by testing how this process is applied to faces of different race and photographic contrast. Participants completed a feature displacement discrimination task, directly measuring the sensitivity to second-order relations between face parts. Across three experiments we show that, despite absolute differences in sensitivity in some conditions, inversion impaired performance in all conditions. The presence of robust inversion effects for all faces suggests that second-order relational processing can be applied to faces of different race and photographic contrast.
Diversity in spatial scope of contrast adaptation among mouse retinal ganglion cells.
Khani, Mohammad Hossein; Gollisch, Tim
2017-12-01
Retinal ganglion cells adapt to changes in visual contrast by adjusting their response kinetics and sensitivity. While much work has focused on the time scales of these adaptation processes, less is known about the spatial scale of contrast adaptation. For example, do small, localized contrast changes affect a cell's signal processing across its entire receptive field? Previous investigations have provided conflicting evidence, suggesting that contrast adaptation occurs either locally within subregions of a ganglion cell's receptive field or globally over the receptive field in its entirety. Here, we investigated the spatial extent of contrast adaptation in ganglion cells of the isolated mouse retina through multielectrode-array recordings. We applied visual stimuli so that ganglion cell receptive fields contained regions where the average contrast level changed periodically as well as regions with constant average contrast level. This allowed us to analyze temporal stimulus integration and sensitivity separately for stimulus regions with and without contrast changes. We found that the spatial scope of contrast adaptation depends strongly on cell identity, with some ganglion cells displaying clear local adaptation, whereas others, in particular large transient ganglion cells, adapted globally to contrast changes. Thus, the spatial scope of contrast adaptation in mouse retinal ganglion cells appears to be cell-type specific. This could reflect differences in mechanisms of contrast adaptation and may contribute to the functional diversity of different ganglion cell types. NEW & NOTEWORTHY Understanding whether adaptation of a neuron in a sensory system can occur locally inside the receptive field or whether it always globally affects the entire receptive field is important for understanding how the neuron processes complex sensory stimuli. For mouse retinal ganglion cells, we here show that both local and global contrast adaptation exist and that this diversity in spatial scope can contribute to the functional diversity of retinal ganglion cell types. Copyright © 2017 the American Physiological Society.
Diversity in spatial scope of contrast adaptation among mouse retinal ganglion cells
Khani, Mohammad Hossein
2017-01-01
Retinal ganglion cells adapt to changes in visual contrast by adjusting their response kinetics and sensitivity. While much work has focused on the time scales of these adaptation processes, less is known about the spatial scale of contrast adaptation. For example, do small, localized contrast changes affect a cell’s signal processing across its entire receptive field? Previous investigations have provided conflicting evidence, suggesting that contrast adaptation occurs either locally within subregions of a ganglion cell’s receptive field or globally over the receptive field in its entirety. Here, we investigated the spatial extent of contrast adaptation in ganglion cells of the isolated mouse retina through multielectrode-array recordings. We applied visual stimuli so that ganglion cell receptive fields contained regions where the average contrast level changed periodically as well as regions with constant average contrast level. This allowed us to analyze temporal stimulus integration and sensitivity separately for stimulus regions with and without contrast changes. We found that the spatial scope of contrast adaptation depends strongly on cell identity, with some ganglion cells displaying clear local adaptation, whereas others, in particular large transient ganglion cells, adapted globally to contrast changes. Thus, the spatial scope of contrast adaptation in mouse retinal ganglion cells appears to be cell-type specific. This could reflect differences in mechanisms of contrast adaptation and may contribute to the functional diversity of different ganglion cell types. NEW & NOTEWORTHY Understanding whether adaptation of a neuron in a sensory system can occur locally inside the receptive field or whether it always globally affects the entire receptive field is important for understanding how the neuron processes complex sensory stimuli. For mouse retinal ganglion cells, we here show that both local and global contrast adaptation exist and that this diversity in spatial scope can contribute to the functional diversity of retinal ganglion cell types. PMID:28904106
Blur adaptation: contrast sensitivity changes and stimulus extent.
Venkataraman, Abinaya Priya; Winter, Simon; Unsbo, Peter; Lundström, Linda
2015-05-01
A prolonged exposure to foveal defocus is well known to affect the visual functions in the fovea. However, the effects of peripheral blur adaptation on foveal vision, or vice versa, are still unclear. In this study, we therefore examined the changes in contrast sensitivity function from baseline, following blur adaptation to small as well as laterally extended stimuli in four subjects. The small field stimulus (7.5° visual field) was a 30min video of forest scenery projected on a screen and the large field stimulus consisted of 7-tiles of the 7.5° stimulus stacked horizontally. Both stimuli were used for adaptation with optical blur (+2.00D trial lens) as well as for clear control conditions. After small field blur adaptation foveal contrast sensitivity improved in the mid spatial frequency region. However, these changes neither spread to the periphery nor occurred for the large field blur adaptation. To conclude, visual performance after adaptation is dependent on the lateral extent of the adaptation stimulus. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Nakatsuka, Matthew A; Barback, Christopher V; Fitch, Kirsten R; Farwell, Alexander R; Esener, Sadik C; Mattrey, Robert F; Cha, Jennifer N; Goodwin, Andrew P
2013-12-01
The use of microbubbles as ultrasound contrast agents is one of the primary methods to diagnose deep venous thrombosis. However, current microbubble imaging strategies require either a clot sufficiently large to produce a circulation filling defect or a clot with sufficient vascularization to allow for targeted accumulation of contrast agents. Previously, we reported the design of a microbubble formulation that modulated its ability to generate ultrasound contrast from interaction with thrombin through incorporation of aptamer-containing DNA crosslinks in the encapsulating shell, enabling the measurement of a local chemical environment by changes in acoustic activity. However, this contrast agent lacked sufficient stability and lifetime in blood to be used as a diagnostic tool. Here we describe a PEG-stabilized, thrombin-activated microbubble (PSTA-MB) with sufficient stability to be used in vivo in circulation with no change in biomarker sensitivity. In the presence of actively clotting blood, PSTA-MBs showed a 5-fold increase in acoustic activity. Specificity for the presence of thrombin and stability under constant shear flow were demonstrated in a home-built in vitro model. Finally, PSTA-MBs were able to detect the presence of an active clot within the vena cava of a rabbit sufficiently small as to not be visible by current non-specific contrast agents. By activating in non-occlusive environments, these contrast agents will be able to detect clots not diagnosable by current contrast agents. Copyright © 2013 Elsevier Ltd. All rights reserved.
Jiang, Dandan; Zhang, Xiaopeng; Yu, Dexin; Xiao, Yanan; Wang, Tianqi; Su, Zhihui; Liu, Yongjun; Zhang, Na
2017-03-01
Magnetic resonance imaging (MRI) contrast agents with tumor-microenvironment changeable relaxivity are effective to increase the sensitivity and selectivity of MRI in tumor diagnosis. In this study, pH-sensitive Gd-loaded Poly(L-lysine)/ Carboxymethyl Chitosan Nanoparticles (Gd-PCNPs) were developed as relaxivity-changeable MRI contrast agents based on the "on–off" switchable strategy. The "on–off" switchable nano-contrast agents were capable of releasing Gd3+ in response to physical stimulation, with structure transformed. Gd-PCNPs could responsively disassemble in an acidic tumor-microenvironment and increase the exchange of protons between water molecules and Gd3+ ions, thus selectively enhance the relaxivity in tumor area. Gd-PCNPs were self-assembled via electrostatic interaction between poly(L-lysine)-diethylenetriamine pentaacetic acid-gadolinium and pH-sensitive carboxymethyl chitosan (CMCS). Gd-PCNPs exhibited spherical shape with uniform particle size distribution (166.00 ± 1 .71 nm) and negative zeta potential (–13.2 ± 4.7 mV). The relaxivity of Gd-PCNPs increased from 6.618 mM–1 · s–1 to 10.008 mM–1 · s–1 when the pH values decrease from 7.4 to 6.0, which was higher than Magnevist® (3.924 mM–1 · s–1 at both pH 7.4 and 6.0 (p <0 05). The changeable relaxivity of Gd/PCNPs would result in enhanced tumor/normal tissue signal contrast, which was verified by in vivo MRI test. In vivo MRI test showed that the signal of Gd-PCNPs was significantly enhanced with prolonged imaging time in tumor tissue compared to Magnevist® (p <0 05). Furthermore, Gd-PCNPs exhibited unobvious in vitro cytotoxicity under the experimental concentrations in B16 cells. No obvious damage was observed in the different tissues of mice. These results indicated that the relaxivity-changeable Gd-PCNPs exhibited demonstrated sensitivity and selectivity in tumor diagnosis with a great potential as a novel MRI contrast agent.
Visual cues of oviposition sites and spectral sensitivity of Cydia strobilella L.
Jakobsson, Johan; Henze, Miriam J; Svensson, Glenn P; Lind, Olle; Anderbrant, Olle
2017-08-01
We investigated whether the spruce seed moth (Cydia strobilella L., Tortricidae: Grapholitini), an important pest in seed orchards of Norway spruce (Picea abies (L.) Karst.), can make use of the spectral properties of its host when searching for flowers to oviposit on. Spectral measurements showed that the flowers, and the cones they develop into, differ from a background of P. abies needles by a higher reflectance of long wavelengths. These differences increase as the flowers develop into mature cones. Electroretinograms (ERGs) in combination with spectral adaptation suggest that C. strobilella has at least three spectral types of photoreceptor; an abundant green-sensitive receptor with maximal sensitivity at wavelength λ max =526nm, a blue-sensitive receptor with λ max =436nm, and an ultraviolet-sensitive receptor with λ max =352nm. Based on our spectral measurements and the receptor properties inferred from the ERGs, we calculated that open flowers, which are suitable oviposition sites, provide detectable achromatic, but almost no chromatic contrasts to the background of needles. In field trials using traps of different spectral properties with or without a female sex pheromone lure, only pheromone-baited traps caught moths. Catches in baited traps were not correlated with the visual contrast of the traps against the background. Thus, visual contrast is probably not the primary cue for finding open host flowers, but it could potentially complement olfaction as a secondary cue, since traps with certain spectral properties caught significantly more moths than others. Copyright © 2017 Elsevier Ltd. All rights reserved.
Ghani, Muhammad. U.; Yan, Aimin; Wong, Molly. D.; Li, Yuhua; Ren, Liqiang; Wu, Xizeng; Liu, Hong
2016-01-01
The objective of this study was to investigate the optimization of a high energy in-line phase sensitive x-ray imaging prototype under different geometric and operating conditions for mammography application. A phase retrieval algorithm based on phase attenuation duality (PAD) was applied to the phase contrast images acquired by the prototype. Imaging performance was investigated at four magnification values of 1.67, 2, 2.5 and 3 using an acrylic edge, an American College of Radiology (ACR) mammography phantom and contrast detail (CD) phantom with tube potentials of 100, 120 and 140 kVp. The ACR and CD images were acquired at the same mean glandular dose (MGD) of 1.29 mGy with a computed radiography (CR) detector of 43.75 µm pixel pitch at a fixed source to image distance (SID) of 170 cm. The x-ray tube focal spot size was kept constant as 7 µm while a 2.5 mm thick aluminum (Al) filter was used for beam hardening. The performance of phase contrast and phase retrieved images were compared with computer simulations based on the relative phase contrast factor (RPF) at high x-ray energies. The imaging results showed that the x-ray tube operated at 100 kVp under the magnification of 2.5 exhibits superior imaging performance which is in accordance to the computer simulations. As compared to the phase contrast images, the phase retrieved images of the ACR and CD phantoms demonstrated improved imaging contrast and target discrimination. We compared the CD phantom images acquired in conventional contact mode with and without the anti-scatter grid using the same prototype at 1.295 mGy and 2.59 mGy using 40 kVp, a 25 µm rhodium (Rh) filter. At the same radiation dose, the phase sensitive images provided improved detection capabilities for both the large and small discs, while compared to the double dose image acquired in conventional mode, the observer study also indicated that the phase sensitive images provided improved detection capabilities for the large discs. This study therefore validates the potential of using high energy phase contrast x-ray imaging to improve lesion detection and reduce radiation dose for clinical applications such as mammography. PMID:26756405
Noninvasive Assessment of Early Dental Lesion Using a Dual-Contrast Photoacoustic Tomography
Cheng, Renxiang; Shao, Jiaojiao; Gao, Xiaoxiang; Tao, Chao; Ge, Jiuyu; Liu, Xiaojun
2016-01-01
Dental hard tissue lesions, including caries, cracked-tooth, etc., are the most prevalent diseases of people worldwide. Dental lesions and correlative diseases greatly decrease the life quality of patients throughout their lifetime. It is still hard to noninvasively detect these dental lesions in their early stages. Photoacoustic imaging is an emerging hybrid technology combining the high spatial resolution of ultrasound in deep tissue with the rich optical contrasts. In this study, a dual-contrast photoacoustic tomography is applied to detect the early dental lesions. One contrast, named B-mode, is related to the optical absorption. It is good at providing the sharp image about the morphological and macro-structural features of the teeth. Another contrast, named S-mode, is associated with the micro-structural and mechanical properties of the hard tissue. It is sensitive to the change of tissue properties induced by the early dental lesions. Experiments show that the comprehensive analysis of dual-contrast information can provide reliable information of the early dental lesions. Moreover, the imaging parameter of S-mode is device-independent and it could measure tissue properties quantitatively. We expect that the proposed scheme could be beneficial for improving safety, accuracy and sensitivity of the clinical diagnosis of the dental lesion. PMID:26902394
Noninvasive Assessment of Early Dental Lesion Using a Dual-Contrast Photoacoustic Tomography
NASA Astrophysics Data System (ADS)
Cheng, Renxiang; Shao, Jiaojiao; Gao, Xiaoxiang; Tao, Chao; Ge, Jiuyu; Liu, Xiaojun
2016-02-01
Dental hard tissue lesions, including caries, cracked-tooth, etc., are the most prevalent diseases of people worldwide. Dental lesions and correlative diseases greatly decrease the life quality of patients throughout their lifetime. It is still hard to noninvasively detect these dental lesions in their early stages. Photoacoustic imaging is an emerging hybrid technology combining the high spatial resolution of ultrasound in deep tissue with the rich optical contrasts. In this study, a dual-contrast photoacoustic tomography is applied to detect the early dental lesions. One contrast, named B-mode, is related to the optical absorption. It is good at providing the sharp image about the morphological and macro-structural features of the teeth. Another contrast, named S-mode, is associated with the micro-structural and mechanical properties of the hard tissue. It is sensitive to the change of tissue properties induced by the early dental lesions. Experiments show that the comprehensive analysis of dual-contrast information can provide reliable information of the early dental lesions. Moreover, the imaging parameter of S-mode is device-independent and it could measure tissue properties quantitatively. We expect that the proposed scheme could be beneficial for improving safety, accuracy and sensitivity of the clinical diagnosis of the dental lesion.
Stable Imaging for Astronomy (SIA)
NASA Astrophysics Data System (ADS)
Beaulieu, Mathilde; Ottogalli, Sebastien; Preis, Olivier; Bresson, Yves; Rivet, Jean-Pierre; Abe, Lyu; Vakili, Farrokh
2014-07-01
One of the most challenging fields of astronomical instrumentation is probably high-contrast imaging since it ultimately combines ultra-high sensitivity at low flux and the ability to cope with photon flux contrasts of several hundreds of millions or even more. These two aspects implicitly require that high-contrast instruments should be highly stable in the sense of the reproducibility of their measurements at different times, but also, continuously stable over time. In most high contrast instruments or experiments, their sensitivity is broken after at most tens of minutes of operation due to uncontrolled and unknown behaviour of the whole experiment regarding the environmental conditions. In this paper, we introduce a general approach of an exhaustive stability study for high-contrast imaging that has been initiated at Lagrange Laboratory, Observatoire de la Côte d'Azur (OCA). On a practical ground, one of the fundamental issues of this study is the metrology, which is the basis of all reproducible measurements. We describe a small experiment designed to understand the behaviour of one of our ultra-precise metrology tools (a commercial sub-nanometric 3-way interferometer) and derive the conditions under which its operation delivers reliable results. The approach will apply to the high-contrast imaging test-bench SPEED, under development at OCA.
Quentin, Romain; Elkin Frankston, Seth; Vernet, Marine; Toba, Monica N.; Bartolomeo, Paolo; Chanes, Lorena; Valero-Cabré, Antoni
2016-01-01
Behavioral and electrophysiological studies in humans and non-human primates have correlated frontal high-beta activity with the orienting of endogenous attention and shown the ability of the latter function to modulate visual performance. We here combined rhythmic transcranial magnetic stimulation (TMS) and diffusion imaging to study the relation between frontal oscillatory activity and visual performance, and we associated these phenomena to a specific set of white matter pathways that in humans subtend attentional processes. High-beta rhythmic activity on the right frontal eye field (FEF) was induced with TMS and its causal effects on a contrast sensitivity function were recorded to explore its ability to improve visual detection performance across different stimulus contrast levels. Our results show that frequency-specific activity patterns engaged in the right FEF have the ability to induce a leftward shift of the psychometric function. This increase in visual performance across different levels of stimulus contrast is likely mediated by a contrast gain mechanism. Interestingly, microstructural measures of white matter connectivity suggest a strong implication of right fronto-parietal connectivity linking the FEF and the intraparietal sulcus in propagating high-beta rhythmic signals across brain networks and subtending top-down frontal influences on visual performance. PMID:25899709
Probabilistic fusion of stereo with color and contrast for bilayer segmentation.
Kolmogorov, Vladimir; Criminisi, Antonio; Blake, Andrew; Cross, Geoffrey; Rother, Carsten
2006-09-01
This paper describes models and algorithms for the real-time segmentation of foreground from background layers in stereo video sequences. Automatic separation of layers from color/contrast or from stereo alone is known to be error-prone. Here, color, contrast, and stereo matching information are fused to infer layers accurately and efficiently. The first algorithm, Layered Dynamic Programming (LDP), solves stereo in an extended six-state space that represents both foreground/background layers and occluded regions. The stereo-match likelihood is then fused with a contrast-sensitive color model that is learned on-the-fly and stereo disparities are obtained by dynamic programming. The second algorithm, Layered Graph Cut (LGC), does not directly solve stereo. Instead, the stereo match likelihood is marginalized over disparities to evaluate foreground and background hypotheses and then fused with a contrast-sensitive color model like the one used in LDP. Segmentation is solved efficiently by ternary graph cut. Both algorithms are evaluated with respect to ground truth data and found to have similar performance, substantially better than either stereo or color/ contrast alone. However, their characteristics with respect to computational efficiency are rather different. The algorithms are demonstrated in the application of background substitution and shown to give good quality composite video output.
Wallis, Thomas S. A.; Dorr, Michael; Bex, Peter J.
2015-01-01
Sensitivity to luminance contrast is a prerequisite for all but the simplest visual systems. To examine contrast increment detection performance in a way that approximates the natural environmental input of the human visual system, we presented contrast increments gaze-contingently within naturalistic video freely viewed by observers. A band-limited contrast increment was applied to a local region of the video relative to the observer's current gaze point, and the observer made a forced-choice response to the location of the target (≈25,000 trials across five observers). We present exploratory analyses showing that performance improved as a function of the magnitude of the increment and depended on the direction of eye movements relative to the target location, the timing of eye movements relative to target presentation, and the spatiotemporal image structure at the target location. Contrast discrimination performance can be modeled by assuming that the underlying contrast response is an accelerating nonlinearity (arising from a nonlinear transducer or gain control). We implemented one such model and examined the posterior over model parameters, estimated using Markov-chain Monte Carlo methods. The parameters were poorly constrained by our data; parameters constrained using strong priors taken from previous research showed poor cross-validated prediction performance. Atheoretical logistic regression models were better constrained and provided similar prediction performance to the nonlinear transducer model. Finally, we explored the properties of an extended logistic regression that incorporates both eye movement and image content features. Models of contrast transduction may be better constrained by incorporating data from both artificial and natural contrast perception settings. PMID:26057546
Magnetic relaxometry as applied to sensitive cancer detection and localization
De Haro, Leyma P.; Karaulanov, Todor; Vreeland, Erika C.; ...
2015-06-02
Abstract Here we describe superparamagnetic relaxometry (SPMR), a technology that utilizes highly sensitive magnetic sensors and superparamagnetic nanoparticles for cancer detection. Using SPMR, we sensitively and specifically detect nanoparticles conjugated to biomarkers for various types of cancer. SPMR offers high contrast In SPMR measurements, a brief magnetizing pulse is used to align superparamagnetic nanoparticles of a discrete size. Following the pulse, an array of superconducting quantum interference detectors (SQUID) sensors detect the decaying magnetization field. NP size is chosen so that, when bound, the induced field decays in seconds. They are functionalized with specific biomarkers and incubated with cancer cellsmore » As a result, superparamagnetic NPs developed here have small size dispersion. Cell incubation studies measure specificity for different cell lines and antibodies with very high contrast.« less
Oral water soluble contrast for the management of adhesive small bowel obstruction.
Abbas, S; Bissett, I P; Parry, B R
2005-01-25
Adhesions are the leading cause of small bowel obstruction. Most adhesive small bowel obstructions resolve following conservative treatment but there is no consensus as to when conservative treatment should be considered unsuccessful and the patient should undergo surgery. Studies have shown that failure of an oral water-soluble contrast to reach the colon after a designated time indicates complete intestinal obstruction that is unlikely to resolve with conservative treatment. Other studies have suggested that the administration of water-soluble contrast is therapeutic in resolving the obstruction. The aims of this review are:1. To determine the reliability of water-soluble contrast media and serial abdominal radiographs in predicting the success of conservative treatment in patients admitted with adhesive small bowel obstruction.2. To determine the efficacy and safety of water-soluble contrast media in reducing the need for surgical intervention and reducing hospital stay in adhesive small bowel obstruction. The search was conducted using MeSH terms: ''Intestinal obstruction'', ''water-soluble contrast'', "Adhesions" and "Gastrografin", and combined with the Cochrane Collaboration highly sensitive search strategy for identifying randomised controlled trials and controlled clinical trials. 1. Prospective studies (to evaluate the diagnostic potential of water-soluble contrast in adhesive small bowel obstruction);2. Randomised clinical trials (to evaluate the therapeutic role). 1. Studies addressing the diagnostic role of water-soluble contrast were critically appraised and data presented as sensitivities, specificities and positive and negative likelihood ratios. Results were pooled and summary receiver operating characteristic (ROC) curve was constructed. 2. A meta-analysis of the data from therapeutic studies was performed using the Mantel -Haenszel test using both the fixed effect and random effects model. The appearance of water-soluble contrast in the caecum on an abdominal radiograph within 24 hours of its administration predicts resolution of an adhesive small bowel obstruction with a pooled sensitivity of 0.96, specificity of 0.96. The area under the curve of the summary ROC was 0.98. Four randomised studies dealing with the therapeutic role of Gastrografin were included in the review, water-soluble contrast did not reduce the need for surgical intervention (odds ratio 1.29, P = 0.36). Meta-analysis of two studies showed that water-soluble contrast reduced hospital stay compared with placebo (weighted mean difference = - 2.58) P = 0.004. Published literature strongly supports the use of water-soluble contrast as a predictive test for non-operative resolution of adhesive small bowel obstruction. Although Gastrografin does not cause resolution of small bowel obstruction, it does appear to reduce hospital stay.
Microenvironment-Sensitive Multimodal Contrast Agent for Prostate Cancer Diagnosis
2014-10-01
which serve as a contrast agent for Magnetic Resonance Imaging (MRI), coated with a biopolymer (i.e. starch ) to improve biocompatibility, and...size stability (i.e. resisted aggregation) and lower protein binding than the unmodified MNP. The MNPs were also incubated for varying time periods with
Didier, Ryne A; Hopkins, Katharine L; Coakley, Fergus V; Krishnaswami, Sanjay; Spiro, David M; Foster, Bryan R
2017-09-01
Magnetic resonance imaging (MRI) has emerged as a promising modality for evaluating pediatric appendicitis. However optimal imaging protocols, including roles of contrast agents and sedation, have not been established and diagnostic criteria have not been fully evaluated. To investigate performance characteristics of rapid MRI without contrast agents or sedation in the diagnosis of pediatric appendicitis. We included patients ages 4-18 years with suspicion of appendicitis who underwent rapid MRI between October 2013 and March 2015 without contrast agent or sedation. After two-radiologist review, we determined performance characteristics of individual diagnostic criteria and aggregate diagnostic criteria by comparing MRI results to clinical outcomes. We used receiver operating characteristic (ROC) curves to determine cut-points for appendiceal diameter and wall thickness for optimization of predictive power, and we calculated area under the curve (AUC) as a measure of test accuracy. Ninety-eight MRI examinations were performed in 97 subjects. Overall, MRI had a 94% sensitivity, 95% specificity, 91% positive predictive value and 97% negative predictive value. Optimal cut-points for appendiceal diameter and wall thickness were ≥7 mm and ≥2 mm, respectively. Independently, those cut-points produced sensitivities of 91% and 84% and specificities of 84% and 43%. Presence of intraluminal fluid (30/33) or localized periappendiceal fluid (32/33) showed a significant association with acute appendicitis (P<0.01), with sensitivities of 91% and 97% and specificities of 60% and 50%. For examinations in which the appendix was not identified by one or both reviewers (23/98), the clinical outcome was negative. Rapid MRI without contrast agents or sedation is accurate for diagnosis of pediatric appendicitis when multiple diagnostic criteria are considered in aggregate. Individual diagnostic criteria including optimized cut-points of ≥7 mm for diameter and ≥2 mm for wall thickness demonstrate high sensitivities but relatively low specificities. Nonvisualization of the appendix favors a negative diagnosis.
Inorganic nanoparticle-based T1 and T1/T2 magnetic resonance contrast probes
NASA Astrophysics Data System (ADS)
Hu, Fengqin; Zhao, Yong Sheng
2012-09-01
Magnetic resonance imaging (MRI) yields high spatially resolved contrast with anatomical details for diagnosis, deeper penetration depth and rapid 3D scanning. To improve imaging sensitivity, adding contrast agents accelerates the relaxation rate of water molecules, thereby greatly increasing the contrast between specific issues or organs of interest. Currently, the majority of T1 contrast agents are paramagnetic molecular complexes, typically Gd(iii) chelates. Various nanoparticulate T1 and T1/T2 contrast agents have recently been investigated as novel agents possessing the advantages of both the T1 contrast effect and nanostructural characteristics. In this minireview, we describe the recent progress of these inorganic nanoparticle-based MRI contrast agents. Specifically, we mainly report on Gd and Mn-based inorganic nanoparticles and ultrasmall iron oxide/ferrite nanoparticles.
Amblyopia in Astigmatic Children: Patterns of Deficits
Harvey, Erin M.; Dobson, Velma; Miller, Joseph M.; Clifford-Donaldson, Candice E.
2007-01-01
Neural changes that result from disruption of normal visual experience during development are termed amblyopia. To characterize visual deficits specific to astigmatism-related amblyopia, we compared best-corrected visual performance in 330 astigmatic and 475 non-astigmatic kindergarten through 6th grade children. Astigmatism was associated with deficits in letter, grating and vernier acuity, high and middle spatial frequency contrast sensitivity, and stereoacuity. Although grating acuity, vernier acuity, and contrast sensitivity were reduced across stimulus orientation, astigmats demonstrated orientation-dependent deficits (meridional amblyopia) only for grating acuity. Astigmatic children are at risk for deficits across a range of visual functions. PMID:17184807
Polarization sensitive optical coherence tomography – a review [Invited
de Boer, Johannes F.; Hitzenberger, Christoph K.; Yasuno, Yoshiaki
2017-01-01
Optical coherence tomography (OCT) is now a well-established modality for high-resolution cross-sectional and three-dimensional imaging of transparent and translucent samples and tissues. Conventional, intensity based OCT, however, does not provide a tissue-specific contrast, causing an ambiguity with image interpretation in several cases. Polarization sensitive (PS) OCT draws advantage from the fact that several materials and tissues can change the light’s polarization state, adding an additional contrast channel and providing quantitative information. In this paper, we review basic and advanced methods of PS-OCT and demonstrate its use in selected biomedical applications. PMID:28663869
NASA Astrophysics Data System (ADS)
Cremons, Daniel R.; Schliep, Karl B.; Flannigan, David J.
2013-09-01
With ultrafast transmission electron microscopy (UTEM), access can be gained to the spatiotemporal scales required to directly visualize rapid, non-equilibrium structural dynamics of materials. This is achieved by operating a transmission electron microscope (TEM) in a stroboscopic pump-probe fashion by photoelectrically generating coherent, well-timed electron packets in the gun region of the TEM. These probe photoelectrons are accelerated down the TEM column where they travel through the specimen before reaching a standard, commercially-available CCD detector. A second laser pulse is used to excite (pump) the specimen in situ. Structural changes are visualized by varying the arrival time of the pump laser pulse relative to the probe electron packet at the specimen. Here, we discuss how ultrafast nanoscale motions of crystalline materials can be visualized and precisely quantified using diffraction contrast in UTEM. Because diffraction contrast sensitively depends upon both crystal lattice orientation as well as incoming electron wavevector, minor spatial/directional variations in either will produce dynamic and often complex patterns in real-space images. This is because sections of the crystalline material that satisfy the Laue conditions may be heterogeneously distributed such that electron scattering vectors vary over nanoscale regions. Thus, minor changes in either crystal grain orientation, as occurs during specimen tilting, warping, or anisotropic expansion, or in the electron wavevector result in dramatic changes in the observed diffraction contrast. In this way, dynamic contrast patterns observed in UTEM images can be used as sensitive indicators of ultrafast specimen motion. Further, these motions can be spatiotemporally mapped such that direction and amplitude can be determined.
Vajapeyam, S; Stamoulis, C; Ricci, K; Kieran, M; Poussaint, T Young
2017-01-01
Pharmacokinetic parameters from dynamic contrast-enhanced MR imaging have proved useful for differentiating brain tumor grades in adults. In this study, we retrospectively reviewed dynamic contrast-enhanced perfusion data from children with newly diagnosed brain tumors and analyzed the pharmacokinetic parameters correlating with tumor grade. Dynamic contrast-enhanced MR imaging data from 38 patients were analyzed by using commercially available software. Subjects were categorized into 2 groups based on pathologic analyses consisting of low-grade (World Health Organization I and II) and high-grade (World Health Organization III and IV) tumors. Pharmacokinetic parameters were compared between the 2 groups by using linear regression models. For parameters that were statistically distinct between the 2 groups, sensitivity and specificity were also estimated. Eighteen tumors were classified as low-grade, and 20, as high-grade. Transfer constant from the blood plasma into the extracellular extravascular space (K trans ), rate constant from extracellular extravascular space back into blood plasma (K ep ), and extracellular extravascular volume fraction (V e ) were all significantly correlated with tumor grade; high-grade tumors showed higher K trans , higher K ep , and lower V e . Although all 3 parameters had high specificity (range, 82%-100%), K ep had the highest specificity for both grades. Optimal sensitivity was achieved for V e , with a combined sensitivity of 76% (compared with 71% for K trans and K ep ). Pharmacokinetic parameters derived from dynamic contrast-enhanced MR imaging can effectively discriminate low- and high-grade pediatric brain tumors. © 2017 by American Journal of Neuroradiology.
Visual and ocular changes associated with exposure to two tertiary amines
Page, E; Cook, C; Hater, M; Mueller, C; Grote, A; Mortimer, V
2003-01-01
Aims: To determine if exposure to dimethylisopropanolamine (DMIPA) and dimethylaminoethanol (DMAE) in a label printing plant was associated with visual disturbances and/or ocular changes. Methods: Questionnaires, eye examinations (visual acuity, contrast sensitivity at 2.5% and 1.25% contrast, slit lamp biomicroscopy, and pachymetry), and industrial hygiene monitoring for DMIPA and DMAE were performed over a two week period. Results: Eighty nine per cent of line workers reported having experienced blurry vision while at work in the past 12 months, compared to 12.5% of prime workers. A total of 108 full shift personal breathing zone (PBZ) air samples for the amines were collected. The mean time weighted average (TWA) concentration of DMIPA was significantly higher in the line division than in the prime division, as was the mean TWA concentration for total amines. The mean TWA concentration of DMAE was higher in the prime division than the line division. Higher levels of total amines were associated with increased risk of reporting blurry vision, halo vision, and blue-grey vision. The risk of corneal opacity rose with increasing exposure to total amines. The prevalence of corneal opacity also increased with increasing concentration of total amines. Median corneal thickness increased with increasing grades of corneal opacity. There was a statistically significant relation between total amine concentration and increased risk of reduced bilateral visual acuity and 2.5% contrast sensitivity. Conclusions: Exposure to tertiary amines was associated with blurry, halo, and blue-grey vision, corneal opacity, and decrements in visual acuity and contrast sensitivity at 2.5% contrast. PMID:12499461
Simulating visibility under reduced acuity and contrast sensitivity.
Thompson, William B; Legge, Gordon E; Kersten, Daniel J; Shakespeare, Robert A; Lei, Quan
2017-04-01
Architects and lighting designers have difficulty designing spaces that are accessible to those with low vision, since the complex nature of most architectural spaces requires a site-specific analysis of the visibility of mobility hazards and key landmarks needed for navigation. We describe a method that can be utilized in the architectural design process for simulating the effects of reduced acuity and contrast on visibility. The key contribution is the development of a way to parameterize the simulation using standard clinical measures of acuity and contrast sensitivity. While these measures are known to be imperfect predictors of visual function, they provide a way of characterizing general levels of visual performance that is familiar to both those working in low vision and our target end-users in the architectural and lighting-design communities. We validate the simulation using a letter-recognition task.
Simulating Visibility Under Reduced Acuity and Contrast Sensitivity
Thompson, William B.; Legge, Gordon E.; Kersten, Daniel J.; Shakespeare, Robert A.; Lei, Quan
2017-01-01
Architects and lighting designers have difficulty designing spaces that are accessible to those with low vision, since the complex nature of most architectural spaces requires a site-specific analysis of the visibility of mobility hazards and key landmarks needed for navigation. We describe a method that can be utilized in the architectural design process for simulating the effects of reduced acuity and contrast on visibility. The key contribution is the development of a way to parameterize the simulation using standard clinical measures of acuity and contrast sensitivity. While these measures are known to be imperfect predictors of visual function, they provide a way of characterizing general levels of visual performance that is familiar to both those working in low vision and our target end-users in the architectural and lighting design communities. We validate the simulation using a letter recognition task. PMID:28375328
Contrast sensitivity perimetry data from adults free of eye disease.
Swanson, William H; Dul, Mitchell W; Horner, Douglas G; Malinovsky, Victor E
2016-09-01
This data article contains data referenced in "Individual Differences in the Shape of the Nasal Visual Field" [1]. The data were gathered from volunteers free of eye disease ages 21-85 who were tested with Contrast Sensitivity Perimetry (CSP), which uses a stimulus resistant to effects of defocus and reduced retinal illumination. Some subjects were tested only once or a few times, and others were part of a longitudinal cohort with as many as 10 tests. Parameters from maximum likelihood estimation of psychophysical threshold at each tested location are included in the data file, along with the participant׳s sex, age at time of test, the center of their physiological blind spot, the duration of test, the time of day that the test was begun, and the starting contrast used for the psychophysical staircases.
NASA Astrophysics Data System (ADS)
Lin, Yuting; Ghijsen, Michael; Thayer, David; Nalcioglu, Orhan; Gulsen, Gultekin
2011-03-01
Dynamic contrast enhanced MRI (DCE-MRI) has been proven to be the most sensitive modality in detecting breast lesions. Currently available MR contrast agent, Gd-DTPA, is a low molecular weight extracellular agent and can diffuse freely from the vascular space into interstitial space. Due to this reason, DCE-MRI has low sensitivity in differentiating benign and malignant tumors. Meanwhile, diffuse optical tomography (DOT) can be used to provide enhancement kinetics of an FDA approved optical contrast agent, ICG, which behaves like a large molecular weight optical agent due to its binding to albumin. The enhancement kinetics of ICG may have a potential to distinguish between the malignant and benign tumors and hence improve the specificity. Our group has developed a high speed hybrid MRI-DOT system. The DOT is a fully automated, MR-compatible, multi-frequency and multi-spectral imaging system. Fischer-344 rats bearing subcutaneous R3230 tumor are injected simultaneously with Gd-DTPA (0.1nmol/kg) and IC-Green (2.5mg/kg). The enhancement kinetics of both contrast agents are recorded simultaneously with this hybrid MRI-DOT system and evaluated for different tumors.
Studies of the Effects of Control Bandwidth and Dark-Hole Size on the HCIT Contrast Performance
NASA Technical Reports Server (NTRS)
Sidick, Erkin; Shaklan, Stuart; Balasubramanian, Kunjithapatha; Cady, Eric
2015-01-01
We have carried out both theoretical and experimental studies of the sensitivity of dark hole contrast to the control bandwidth and dark-hole dimensions in high-contrast broadband stellar coronagraphy. We have evaluated the performance of DM actuator solutions in the presence of occulting mask defects using one to five 2% -wide bands spanning a 10% bandpass. We have also investigated the dependence of the HCIT contrast performance on the size of dark -hole area including large dark holes formed at the Nyquist limit of the DM.
Studies of the effects of control bandwidth and dark-hole size on the HCIT contrast performance
NASA Astrophysics Data System (ADS)
Sidick, Erkin; Shaklan, Stuart; Balasubramanian, Kunjithapatham; Cady, Eric
2015-09-01
We have carried out both theoretical and experimental studies of the sensitivity of dark hole contrast to the control bandwidth and dark-hole dimensions in high-contrast broadband stellar coronagraphy. We have evaluated the performance of DM actuator solutions in the presence of occulting mask defects using one to five 2%-wide bands spanning a 10% bandpass. We have also investigated the dependence of the HCIT contrast performance on the size of dark-hole area including large dark holes formed at the Nyquist limit of the DM.
Compensation for red-green contrast loss in anomalous trichromats
Boehm, A. E.; MacLeod, D. I. A.; Bosten, J. M.
2014-01-01
For anomalous trichromats, threshold contrasts for color differences captured by the L and M cones and their anomalous analogs are much higher than for normal trichromats. The greater spectral overlap of the cone sensitivities reduces chromatic contrast both at and above threshold. But above threshold, adaptively nonlinear processing might compensate for the chromatically impoverished photoreceptor inputs. Ratios of sensitivity for threshold variations and for color appearance along the two cardinal axes of MacLeod-Boynton chromaticity space were calculated for three groups: normals (N = 15), deuteranomals (N = 9), and protanomals (N = 5). Using a four-alternative forced choice (4AFC) task, threshold sensitivity was measured in four color-directions along the two cardinal axes. For the same participants, we reconstructed perceptual color spaces for the positions of 25 hues using multidimensional scaling (MDS). From the reconstructed color spaces we extracted “color difference ratios,” defined as ratios for the size of perceived color differences along the L/(L + M) axis relative to those along the S/(L + M) axis, analogous to “sensitivity ratios” extracted from the 4AFC task. In the 4AFC task, sensitivity ratios were 38% of normal for deuteranomals and 19% of normal for protanomals. Yet, in the MDS results, color difference ratios were 86% of normal for deuteranomals and 67% of normal for protanomals. Thus, the contraction along the L/(L + M) axis shown in the perceptual color spaces of anomalous trichromats is far smaller than predicted by their reduced sensitivity, suggesting that an adaptive adjustment of postreceptoral gain may magnify the cone signals of anomalous trichromats to exploit the range of available postreceptoral neural signals. PMID:25413625