Sample records for control aec devices

  1. Feasibility study on an integrated AEC-grid device for the optimization of image quality and exposure dose in mammography

    NASA Astrophysics Data System (ADS)

    Kim, Kyo-Tae; Yun, Ryang-Young; Han, Moo-Jae; Heo, Ye-Ji; Song, Yong-Keun; Heo, Sung-Wook; Oh, Kyeong-Min; Park, Sung-Kwang

    2017-10-01

    Currently, in the radiation diagnosis field, mammography is used for the early detection of breast cancer. In addition, studies are being conducted on a grid to produce high-quality images. Although the grid ratio of the grid, which affects the scattering removal rate, must be increased to improve image quality, it increases the total exposure dose. While the use of automatic exposure control is recommended to minimize this problem, existing mammography equipment, unlike general radiography equipment, is mounted on the back of a detector. Therefore, the device is greatly affected by the detector and supporting device, and it is difficult to control the exposure dose. Accordingly, in this research, an integrated AEC-grid device that simultaneously performs AEC and grid functions was used to minimize the unnecessary exposure dose while removing scattering, thereby realizing superior image quality.

  2. Automatic exposure control calibration and optimisation for abdomen, pelvis and lumbar spine imaging with an Agfa computed radiography system.

    PubMed

    Moore, C S; Wood, T J; Avery, G; Balcam, S; Needler, L; Joshi, H; Saunderson, J R; Beavis, A W

    2016-11-07

    The use of three physical image quality metrics, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and mean effective noise equivalent quanta (eNEQ m ) have recently been examined by our group for their appropriateness in the calibration of an automatic exposure control (AEC) device for chest radiography with an Agfa computed radiography (CR) imaging system. This study uses the same methodology but investigates AEC calibration for abdomen, pelvis and spine CR imaging. AEC calibration curves were derived using a simple uniform phantom (equivalent to 20 cm water) to ensure each metric was held constant across the tube voltage range. Each curve was assessed for its clinical appropriateness by generating computer simulated abdomen, pelvis and spine images (created from real patient CT datasets) with appropriate detector air kermas for each tube voltage, and grading these against reference images which were reconstructed at detector air kermas correct for the constant detector dose indicator (DDI) curve currently programmed into the AEC device. All simulated images contained clinically realistic projected anatomy and were scored by experienced image evaluators. Constant DDI and CNR curves did not provide optimized performance but constant eNEQ m and SNR did, with the latter being the preferred calibration metric given that it is easier to measure in practice. This result was consistent with the previous investigation for chest imaging with AEC devices. Medical physicists may therefore use a simple and easily accessible uniform water equivalent phantom to measure the SNR image quality metric described here when calibrating AEC devices for abdomen, pelvis and spine imaging with Agfa CR systems, in the confidence that clinical image quality will be sufficient for the required clinical task. However, to ensure appropriate levels of detector air kerma the advice of expert image evaluators must be sought.

  3. Automatic exposure control calibration and optimisation for abdomen, pelvis and lumbar spine imaging with an Agfa computed radiography system

    NASA Astrophysics Data System (ADS)

    Moore, C. S.; Wood, T. J.; Avery, G.; Balcam, S.; Needler, L.; Joshi, H.; Saunderson, J. R.; Beavis, A. W.

    2016-11-01

    The use of three physical image quality metrics, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and mean effective noise equivalent quanta (eNEQm) have recently been examined by our group for their appropriateness in the calibration of an automatic exposure control (AEC) device for chest radiography with an Agfa computed radiography (CR) imaging system. This study uses the same methodology but investigates AEC calibration for abdomen, pelvis and spine CR imaging. AEC calibration curves were derived using a simple uniform phantom (equivalent to 20 cm water) to ensure each metric was held constant across the tube voltage range. Each curve was assessed for its clinical appropriateness by generating computer simulated abdomen, pelvis and spine images (created from real patient CT datasets) with appropriate detector air kermas for each tube voltage, and grading these against reference images which were reconstructed at detector air kermas correct for the constant detector dose indicator (DDI) curve currently programmed into the AEC device. All simulated images contained clinically realistic projected anatomy and were scored by experienced image evaluators. Constant DDI and CNR curves did not provide optimized performance but constant eNEQm and SNR did, with the latter being the preferred calibration metric given that it is easier to measure in practice. This result was consistent with the previous investigation for chest imaging with AEC devices. Medical physicists may therefore use a simple and easily accessible uniform water equivalent phantom to measure the SNR image quality metric described here when calibrating AEC devices for abdomen, pelvis and spine imaging with Agfa CR systems, in the confidence that clinical image quality will be sufficient for the required clinical task. However, to ensure appropriate levels of detector air kerma the advice of expert image evaluators must be sought.

  4. OVERVIEW, PRACTICAL TIPS AND POTENTIAL PITFALLS OF USING AUTOMATIC EXPOSURE CONTROL IN CT: SIEMENS CARE DOSE 4D.

    PubMed

    Söderberg, Marcus

    2016-06-01

    Today, computed tomography (CT) systems routinely use automatic exposure control (AEC), which modulates the tube current. However, for optimal use, there are several aspects of an AEC system that need to be considered. The purpose of this study was to provide an overview of the Siemens CARE Dose 4D AEC system, discuss practical tips and demonstrate potential pitfalls. Two adult anthropomorphic phantoms were examined using two different Siemens CT systems. When optimising the CT radiation dose and image quality, the projection angle of the localiser, patient centring, protocol selection, scanning direction and the use of protective devices requires special attention. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Excess of Radiation Burden for Young Testicular Cancer Patients using Automatic Exposure Control and Contrast Agent on Whole-body Computed Tomography Imaging.

    PubMed

    Niiniviita, Hannele; Kulmala, Jarmo; Pölönen, Tuukka; Määttänen, Heli; Järvinen, Hannu; Salminen, Eeva

    2017-06-01

    The aim of the study was to assess patient dose from whole-body computed tomography (CT) in association with patient size, automatic exposure control (AEC) and intravenous (IV) contrast agent. Sixty-five testicular cancer patients (mean age 28 years) underwent altogether 279 whole-body CT scans from April 2000 to April 2011. The mean number of repeated examinations was 4.3. The GE LightSpeed 16 equipped with AEC and the Siemens Plus 4 CT scanners were used for imaging. Whole-body scans were performed with (216) and without (63) IV contrast. The ImPACT software was used to determine the effective and organ doses. Patient doses were independent (p < 0.41) of patient size when the Plus 4 device (mean 7.4 mSv, SD 1.7 mSv) was used, but with the LightSpeed 16 AEC device, the dose (mean 14 mSv, SD 4.6 mSv) increased significantly (p < 0.001) with waist cirfumference. Imaging with the IV contrast agent caused significantly higher (13% Plus 4, 35% LightSpeed 16) exposure than non-contrast imaging (p < 0.001). Great caution on the use of IV contrast agent and careful set-up of the AEC modulation parameters is recommended to avoid excessive radiation exposure on the whole-body CT imaging of young patients.

  6. Macroscopic barotrauma caused by stiff and soft-tipped airway exchange catheters: an in vitro case series.

    PubMed

    Axe, Robert; Middleditch, Alex; Kelly, Fiona E; Batchelor, Tim J; Cook, Tim M

    2015-02-01

    Many airway management guidelines include the use of airway exchange catheters (AECs). There are reports, however, of harm from their use, from both malpositioning and in particular from the administration of oxygen via an AEC leading to barotrauma. We used an in vitro pig lung model to investigate the safety of administering oxygen at 4 different flow rates from a high-pressure source via 2 different AECs: a standard catheter and a soft-tipped catheter. Experiments were performed with the catheters positioned either above the carina or below it at the first point of resistance to advancement (hold-up). The experiments were then repeated to produce a series of 32 cases. With an AEC positioned above the carina, we did not observe macroscopic lung damage after the administration of oxygen. The administration of oxygen through an AEC positioned below the carina resulted in macroscopic barotrauma regardless of the rate of oxygen delivery. Increasing speed of oxygen flow led to faster and more extensive damage. Use of an "injector" at 2.5 or 4 bar led to instantaneous macroscopic lung damage and advancement of the AEC through the lung tissue. Our observations were the same when both types of AECs were used. Our results are consistent with reports of harm during the use of AECs and demonstrate the risk of administering oxygen through these devices when they are positioned below the carina. An indicator, ideally made on an AEC at the time of manufacture and designed to lie at the same level as the teeth, may be useful in preventing the insertion of that AEC beyond the level of the carina and improve the safety of using such devices.

  7. Inverted Control Rod Lock-In Device

    DOEpatents

    Brussalis, W. G.; Bost, G. E.

    1962-12-01

    A mechanism which prevents control rods from dropping out of the reactor core in the event the vessel in which the reactor is mounted should capsize is described. The mechanism includes a pivoted toothed armature which engages the threaded control rod lead screw and prevents removal of the rod whenever the armature is not attracted by the provided electromagnetic means. (AEC)

  8. GRIPPING DEVICE FOR CYLINDRICAL OBJECTS

    DOEpatents

    Pilger, J.P.

    1964-01-21

    A gripping device is designed for fragile cylindrical objects such as for drawing thin-walled tubes. The gripping is done by multiple jaw members held in position by two sets of slots, one defined by keystone-shaped extensions of the outer shell of the device and the other in a movable sleeve held slidably by the extensions. Forward movement oi the sleeve advances the jaws, thereby exerting a controlled, radial pressure on the object being gripped. (AEC)

  9. REACTOR CONTROL DEVICE

    DOEpatents

    Graham, R.H.

    1962-09-01

    A wholly mechanical compact control device is designed for automatically rendering the core of a fission reactor subcritical in response to core temperatures in excess of the design operating temperature limit. The control device comprises an expansible bellows interposed between the base of a channel in a reactor core and the inner end of a fuel cylinder therein which is normally resiliently urged inwardly. The bellows contains a working fluid which undergoes a liquid to vapor phase change at a temperature substantially equal to the design temperature limit. Hence, the bellows abruptiy expands at this limiting temperature to force the fuel cylinder outward and render the core subcritical. The control device is particularly applicable to aircraft propulsion reactor service. (AEC)

  10. An investigation of automatic exposure control calibration for chest imaging with a computed radiography system.

    PubMed

    Moore, C S; Wood, T J; Avery, G; Balcam, S; Needler, L; Beavis, A W; Saunderson, J R

    2014-05-07

    The purpose of this study was to examine the use of three physical image quality metrics in the calibration of an automatic exposure control (AEC) device for chest radiography with a computed radiography (CR) imaging system. The metrics assessed were signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and mean effective noise equivalent quanta (eNEQm), all measured using a uniform chest phantom. Subsequent calibration curves were derived to ensure each metric was held constant across the tube voltage range. Each curve was assessed for its clinical appropriateness by generating computer simulated chest images with correct detector air kermas for each tube voltage, and grading these against reference images which were reconstructed at detector air kermas correct for the constant detector dose indicator (DDI) curve currently programmed into the AEC device. All simulated chest images contained clinically realistic projected anatomy and anatomical noise and were scored by experienced image evaluators. Constant DDI and CNR curves do not appear to provide optimized performance across the diagnostic energy range. Conversely, constant eNEQm and SNR do appear to provide optimized performance, with the latter being the preferred calibration metric given as it is easier to measure in practice. Medical physicists may use the SNR image quality metric described here when setting up and optimizing AEC devices for chest radiography CR systems with a degree of confidence that resulting clinical image quality will be adequate for the required clinical task. However, this must be done with close cooperation of expert image evaluators, to ensure appropriate levels of detector air kerma.

  11. An investigation of automatic exposure control calibration for chest imaging with a computed radiography system

    NASA Astrophysics Data System (ADS)

    Moore, C. S.; Wood, T. J.; Avery, G.; Balcam, S.; Needler, L.; Beavis, A. W.; Saunderson, J. R.

    2014-05-01

    The purpose of this study was to examine the use of three physical image quality metrics in the calibration of an automatic exposure control (AEC) device for chest radiography with a computed radiography (CR) imaging system. The metrics assessed were signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and mean effective noise equivalent quanta (eNEQm), all measured using a uniform chest phantom. Subsequent calibration curves were derived to ensure each metric was held constant across the tube voltage range. Each curve was assessed for its clinical appropriateness by generating computer simulated chest images with correct detector air kermas for each tube voltage, and grading these against reference images which were reconstructed at detector air kermas correct for the constant detector dose indicator (DDI) curve currently programmed into the AEC device. All simulated chest images contained clinically realistic projected anatomy and anatomical noise and were scored by experienced image evaluators. Constant DDI and CNR curves do not appear to provide optimized performance across the diagnostic energy range. Conversely, constant eNEQm and SNR do appear to provide optimized performance, with the latter being the preferred calibration metric given as it is easier to measure in practice. Medical physicists may use the SNR image quality metric described here when setting up and optimizing AEC devices for chest radiography CR systems with a degree of confidence that resulting clinical image quality will be adequate for the required clinical task. However, this must be done with close cooperation of expert image evaluators, to ensure appropriate levels of detector air kerma.

  12. NEUTRONIC REACTOR MANIPULATING DEVICE

    DOEpatents

    Ohlinger, L.A.

    1962-08-01

    A cable connecting a control rod in a reactor with a motor outside the reactor for moving the rod, and a helical conduit in the reactor wall, through which the cable passes are described. The helical shape of the conduit prevents the escape of certain harmful radiations from the reactor. (AEC)

  13. VEHICLE FOR SLAVE ROBOT

    DOEpatents

    Goertz, R.C.; Lindberg, J.F.

    1962-01-30

    A reeling device is designed for an electrical cable supplying power to the slave slde of a remote control manipulator mounted on a movable vehicle. As the vehicle carries the slave side about in a closed room, the device reels the cable in and out to maintain a variable length of the cable between the vehicle and a cable inlet in the wall of the room. The device also handles a fixed length of cable between the slave side and the vehicle, in spite of angular movement of the slave side with respect to the vehicle. (AEC)

  14. APPARATUS FOR MINIMIZING ENERGY LOSSES FROM MAGNETICALLY CONFINED VOLUMES OF HOT PLASMA

    DOEpatents

    Post, R.F.

    1961-10-01

    An apparatus is described for controlling electron temperature in plasma confined in a Pyrotron magnetic containment field. Basically the device comprises means for directing low temperature electrons to the plasma in controlled quantities to maintain a predetermined optimum equilibrium electron temperature whereat minimum losses of plasma ions due to ambipolar effects and energy damping of the ions due to dynamical friction with the electrons occur. (AEC)

  15. Chest Computed Tomography Radiation Dose Optimization: Comparison of Automatic Exposure Control Strength Curves.

    PubMed

    Gyssels, Elodie; Bohy, Pascale; Cornil, Arnaud; van Muylem, Alain; Howarth, Nigel; Gevenois, Pierre A; Tack, Denis

    2016-01-01

    The aim of the study was to compare radiation dose and image quality between the "average" and the "very strong" automatic exposure control (AEC) strength curves. Images reconstructed with filtered back-projection techniques and radiation dose data of unenhanced helical chest computed tomography (CT) examinations obtained at 2 hospitals (hospital A, hospital B) using the same scanner devices and acquisition protocols but different AEC strength curves were evaluated over a 3-month period. The selected AEC strength curve applied to "slim" patients (diameter <32 cm estimated from the attenuation automatically measured on the topogram) was "average" and "very strong" in hospital A and hospital B, respectively. Two radiologists with 13 and 24 years of experience scored the image quality of the lung parenchyma and the mediastinum on a 5-point scale. The patients' effective diameter, the delivered CT dose index volume, and dose-length products were recorded. A total of 410 patients were included. The average body mass index was 24.0 kg/m in hospital A and 24.8 kg/m in hospital B. There was no significant difference between hospitals with respect to age, sex ratio, weight, height, body mass index, effective diameters, and image quality scores for each radiologist (P ranging from 0.050 to 1.000). The mean CT dose index volume for the entire population was 2.0 mGy and was significantly lower in hospital B with the "very strong" AEC curve as compared with hospital A (-11%, P=0.001). The mean dose-length product delivered in this 70 kg-weight population was 68 mGy cm, corresponding to an effective dose of 0.95 mSv. Changing the AEC strength curve from "average" to "very strong" for slim patients maintains image quality and reduces the radiation dose to <1 mSv in routine chest CT examinations reconstructed with filtered back-projection techniques.

  16. Human-like Compliance for Dexterous Robot Hands

    NASA Technical Reports Server (NTRS)

    Jau, Bruno M.

    1995-01-01

    This paper describes the Active Electromechanical Compliance (AEC) system that was developed for the Jau-JPL anthropomorphic robot. The AEC system imitates the functionality of the human muscle's secondary function, which is to control the joint's stiffness: AEC is implemented through servo controlling the joint drive train's stiffness. The control strategy, controlling compliant joints in teleoperation, is described. It enables automatic hybrid position and force control through utilizing sensory feedback from joint and compliance sensors. This compliant control strategy is adaptable for autonomous robot control as well. Active compliance enables dual arm manipulations, human-like soft grasping by the robot hand, and opens the way to many new robotics applications.

  17. Agro-ecological class stability decreases in response to climate change projections for the Pacific Northwest, USA

    USDA-ARS?s Scientific Manuscript database

    Climate change will impact bioclimatic drivers that regulate the geospatial distribution of dryland agro-ecological classes (AECs). Characterizing the geospatial relationship between present AECs and their bioclimatic controls will provide insights into potential future shifts in AECs as climate cha...

  18. Design and realization of an AEC&AGC system for the CCD aerial camera

    NASA Astrophysics Data System (ADS)

    Liu, Hai ying; Feng, Bing; Wang, Peng; Li, Yan; Wei, Hao yun

    2015-08-01

    An AEC and AGC(Automatic Exposure Control and Automatic Gain Control) system was designed for a CCD aerial camera with fixed aperture and electronic shutter. The normal AEC and AGE algorithm is not suitable to the aerial camera since the camera always takes high-resolution photographs in high-speed moving. The AEC and AGE system adjusts electronic shutter and camera gain automatically according to the target brightness and the moving speed of the aircraft. An automatic Gamma correction is used before the image is output so that the image is better for watching and analyzing by human eyes. The AEC and AGC system could avoid underexposure, overexposure, or image blurring caused by fast moving or environment vibration. A series of tests proved that the system meet the requirements of the camera system with its fast adjusting speed, high adaptability, high reliability in severe complex environment.

  19. Atmosphere Explorer control system software (version 2.0)

    NASA Technical Reports Server (NTRS)

    Mocarsky, W.; Villasenor, A.

    1973-01-01

    The Atmosphere Explorer Control System (AECS) was developed to provide automatic computer control of the Atmosphere Explorer spacecraft and experiments. The software performs several vital functions, such as issuing commands to the spacecraft and experiments, receiving and processing telemetry data, and allowing for extensive data processing by experiment analysis programs. The AECS was written for a 48K XEROX Data System Sigma 5 computer, and coexists in core with the XDS Real-time Batch Monitor (RBM) executive system. RBM is a flexible operating system designed for a real-time foreground/background environment, and hence is ideally suited for this application. Existing capabilities of RBM have been used as much as possible by AECS to minimize programming redundancy. The most important functions of the AECS are to send commands to the spacecraft and experiments, and to receive, process, and display telemetry data.

  20. PLASMA DEVICE

    DOEpatents

    Baker, W.R.; Brathenahl, A.; Furth, H.P.

    1962-04-10

    A device for producing a confined high temperature plasma is described. In the device the concave inner surface of an outer annular electrode is disposed concentrically about and facing the convex outer face of an inner annular electrode across which electrodes a high potential is applied to produce an electric field there between. Means is provided to create a magnetic field perpendicular to the electric field and a gas is supplied at reduced pressure in the area therebetween. Upon application of the high potential, the gas between the electrodes is ionized, heated, and under the influence of the electric and magnetic fields there is produced a rotating annular plasma disk. The ionized plasma has high dielectric constant properties. The device is useful as a fast discharge rate capacitor, in controlled thermonuclear research, and other high temperature gas applications. (AEC)

  1. Macrophage Control of Phagocytosed Mycobacteria Is Increased by Factors Secreted by Alveolar Epithelial Cells through Nitric Oxide Independent Mechanisms

    PubMed Central

    Freidl, Raphaela; Fernández, Carmen

    2014-01-01

    Tissue-resident macrophages are heterogeneous with tissue-specific and niche-specific functions. Thus, simplified models of macrophage activation do not explain the extent of heterogeneity seen in vivo. We focus here on the respiratory tract and ask whether factors secreted by alveolar epithelial cells (AEC) can influence the functionality of resident pulmonary macrophages (PuM). We have previously reported that factors secreted by AEC increase control of intracellular growth of BCG in macrophages. In the current study, we also aimed to investigate possible mechanisms by which AEC-derived factors increase intracellular control of BCG in both primary murine interstitial macrophages, and bone marrow-derived macrophages and characterize further the effect of these factors on macrophage differentiation. We show that; a) in contrast to other macrophage types, IFN-γ did not increase intracellular growth control of Mycobacterium bovis, Bacillus Calmette-Guérin (BCG) by interstitial pulmonary macrophages although the same macrophages could be activated by factors secreted by AEC; b) the lack of response of pulmonary macrophages to IFN-γ was apparently regulated by suppressor of cytokine signaling (SOCS)1; c) AEC-derived factors did not induce pro-inflammatory pathways induced by IFN-γ e.g. expression of inducible nitric oxide synthase (iNOS), secretion of nitric oxide (NO), or IL-12, d) in contrast to IFN-γ, intracellular bacterial destruction induced by AEC-derived factors was not dependent on iNOS transcription and NO production. Collectively, our data show that PuM were restricted in inflammatory responses mediated by IFN-γ through SOCS1 and that factors secreted by AEC- enhanced the microbicidal capacities of macrophages by iNOS independent mechanisms. PMID:25089618

  2. Should the automatic exposure control system of CT be disabled when scanning patients with endoaortic stents or mechanical heart valves? A phantom study.

    PubMed

    Di Leo, Giovanni; Spadavecchia, Chiara; Zanardo, Moreno; Secchi, Francesco; Veronese, Ivan; Cantone, Marie Claire; Sardanelli, Francesco

    2017-07-01

    To estimate the impact of endoaortic stents/mechanical heart valves on the output of an automatic exposure control (AEC) system and CT radiation dose. In this phantom study, seven stents and two valves were scanned with varying tube voltage (80/100/120 kVp), AEC activation (enabled/disabled) and prosthesis (present/absent), for a total of 540 scans. For each prosthesis, the dose-length product (DLP) was compared between scans with the AEC enabled and disabled. Percentage confidence levels for differences due to the prosthesis were calculated. Differences between results with the AEC enabled and disabled were not statistically significant (p ≥ 0.059). In the comparison with and without the prosthesis, DLP was unchanged at 80 kVp and 100 kVp, while a slight increase was observed at 120 kVp. The radiation dose varied from 1.8 mGy to 2.4 mGy without the prosthesis and from 1.8 mGy to 2.5 mGy with the prosthesis (confidence level 37-100%). The effect of the prosthesis on the AEC system was negligible and not clinically relevant. Therefore, disabling the AEC system when scanning these patients is not likely to provide a benefit. • CT-AEC system is not impaired in patients with endoaortic prostheses/heart valves. • Negligible differences may be observed only at 120 kVp. • Disabling the AEC system in these patients is not recommended.

  3. Decreased Fibronectin Production Significantly Contributes to Dysregulated Repair of Asthmatic Epithelium

    PubMed Central

    Kicic, Anthony; Hallstrand, Teal S.; Sutanto, Erika N.; Stevens, Paul T.; Kobor, Michael S.; Taplin, Christopher; Paré, Peter D.; Beyer, Richard P.; Stick, Stephen M.; Knight, Darryl A.

    2010-01-01

    Rationale: Damage to airway epithelium is followed by deposition of extracellular matrix (ECM) and migration of adjacent epithelial cells. We have shown that epithelial cells from children with asthma fail to heal a wound in vitro. Objectives: To determine whether dysregulated ECM production by the epithelium plays a role in aberrant repair in asthma. Methods: Airway epithelial cells (AEC) from children with asthma (n = 36), healthy atopic control subjects (n = 23), and healthy nonatopic control subjects (n = 53) were investigated by microarray, gene expression and silencing, transcript regulation analysis, and ability to close mechanical wounds. Measurements and Main Results: Time to repair a mechanical wound in vitro by AEC from healthy and atopic children was not significantly different and both were faster than AEC from children with asthma. Microarray analysis revealed differential expression of multiple gene sets associated with repair and remodeling in asthmatic AEC. Fibronectin (FN) was the only ECM component whose expression was significantly lower in asthmatic AEC. Expression differences were verified by quantitative polymerase chain reaction and ELISA, and reduced FN expression persisted in asthmatic cells over passage. Silencing of FN expression in nonasthmatic AEC inhibited wound repair, whereas addition of FN to asthmatic AEC restored reparative capacity. Asthmatic AEC failed to synthesize FN in response to wounding or cytokine/growth factor stimulation. Exposure to 5′, 2′deoxyazacytidine had no effect on FN expression and subsequent analysis of the FN promoter did not show evidence of DNA methylation. Conclusions: These data show that the reduced capacity of asthmatic epithelial cells to secrete FN is an important contributor to the dysregulated AEC repair observed in these cells. PMID:20110557

  4. The effective dose result of 18F-FDG PET-CT paediatric patients

    NASA Astrophysics Data System (ADS)

    Hussin, D.; Said, M. A.; Ali, N. S.; Tajuddin, A. A.; Zainon, R.

    2017-05-01

    Paediatric patient received high exposure from both CT and PET examination. Automatic Exposure Control (AEC) is important in CT dose reduction. This study aimed to compare the effective dose obtained from PET-CT scanner with and without the use of AEC function. In this study, 68 patients underwent PET-CT examination without the use of AEC function, while 25 patients used the AEC function during the examination. Patients involved in this study were between 2 to 15 years old with varies of malignancies and epilepsy diseases. The effective dose obtained from PET and CT examinations was calculated based on recommendation from International Commission on Radiological Protection (ICRP) Publication 106 and ICRP publication 102. The outcome of this study shows that the radiation dose was reduced up to 20% with the use of AEC function. The mean average of effective dose result obtained from PET and CT examinations without the use of AEC and AEC function were found to be as 6.67 mSv, 6.77 mSv, 6.03mSv and 4.96 mSv respectively. Where total effective dose result of PET-CT with non-AEC and AEC were found to be 13.44 mSv and 10.99 mSv respectively. Conclusion of this study is, the installation of AEC function in PET-CT machine does play important role in CT dose reduction especially for paediatric patient.

  5. The role of alveolar epithelial cells in initiating and shaping pulmonary immune responses: communication between innate and adaptive immune systems.

    PubMed

    Chuquimia, Olga D; Petursdottir, Dagbjort H; Rahman, Muhammad J; Hartl, Katharina; Singh, Mahavir; Fernández, Carmen

    2012-01-01

    Macrophages and dendritic cells have been recognized as key players in the defense against mycobacterial infection. However, more recently, other cells in the lungs such as alveolar epithelial cells (AEC) have been found to play important roles in the defense and pathogenesis of infection. In the present study we first compared AEC with pulmonary macrophages (PuM) isolated from mice in their ability to internalize and control Bacillus Calmette-Guérin (BCG) growth and their capacity as APCs. AEC were able to internalize and control bacterial growth as well as present antigen to primed T cells. Secondly, we compared both cell types in their capacity to secrete cytokines and chemokines upon stimulation with various molecules including mycobacterial products. Activated PuM and AEC displayed different patterns of secretion. Finally, we analyzed the profile of response of AEC to diverse stimuli. AEC responded to both microbial and internal stimuli exemplified by TLR ligands and IFNs, respectively. The response included synthesis by AEC of several factors, known to have various effects in other cells. Interestingly, TNF could stimulate the production of CCL2/MCP-1. Since MCP-1 plays a role in the recruitment of monocytes and macrophages to sites of infection and macrophages are the main producers of TNF, we speculate that both cell types can stimulate each other. Also, another cell-cell interaction was suggested when IFNs (produced mainly by lymphocytes) were able to induce expression of chemokines (IP-10 and RANTES) by AEC involved in the recruitment of circulating lymphocytes to areas of injury, inflammation, or viral infection. In the current paper we confirm previous data on the capacity of AEC regarding internalization of mycobacteria and their role as APC, and extend the knowledge of AEC as a multifunctional cell type by assessing the secretion of a broad array of factors in response to several different types of stimuli.

  6. Is Weight-Based Adjustment of Automatic Exposure Control Necessary for the Reduction of Chest CT Radiation Dose?

    PubMed Central

    Prakash, Priyanka; Gilman, Matthew D.; Shepard, Jo-Anne O.; Digumarthy, Subba R.

    2010-01-01

    Objective To assess the effects of radiation dose reduction in the chest CT using a weight-based adjustment of the automatic exposure control (AEC) technique. Materials and Methods With Institutional Review Board Approval, 60 patients (mean age, 59.1 years; M:F = 35:25) and 57 weight-matched patients (mean age, 52.3 years, M:F = 25:32) were scanned using a weight-adjusted AEC and non-weight-adjusted AEC, respectively on a 64-slice multidetector CT with a 0.984:1 pitch, 0.5 second rotation time, 40 mm table feed/rotation, and 2.5 mm section thickness. Patients were categorized into 3 weight categories; < 60 kg (n = 17), 60-90 kg (n = 52), and > 90 kg (n = 48). Patient weights, scanning parameters, CT dose index volumes (CTDIvol) and dose length product (DLP) were recorded, while effective dose (ED) was estimated. Image noise was measured in the descending thoracic aorta. Data were analyzed using a standard statistical package (SAS/STAT) (Version 9.1, SAS institute Inc, Cary, NC). Results Compared to the non-weight-adjusted AEC, the weight-adjusted AEC technique resulted in an average decrease of 29% in CTDIvol and a 27% effective dose reduction (p < 0.0001). With weight-adjusted AEC, the CTDIvol decreased to 15.8, 15.9, and 27.3 mGy for the < 60, 60-90 and > 91 kg weight groups, respectively, compared to 20.3, 27.9 and 32.8 mGy, with non-weight-adjusted AEC. No significant difference was observed for objective image noise between the chest CT acquired with the non-weight-adjusted (15.0 ± 3.1) and weight-adjusted (16.1 ± 5.6) AEC techniques (p > 0.05). Conclusion The results of this study suggest that AEC should be tailored according to patient weight. Without weight-based adjustment of AEC, patients are exposed to a 17 - 43% higher radiation-dose from a chest CT. PMID:20046494

  7. Is weight-based adjustment of automatic exposure control necessary for the reduction of chest CT radiation dose?

    PubMed

    Prakash, Priyanka; Kalra, Mannudeep K; Gilman, Matthew D; Shepard, Jo-Anne O; Digumarthy, Subba R

    2010-01-01

    To assess the effects of radiation dose reduction in the chest CT using a weight-based adjustment of the automatic exposure control (AEC) technique. With Institutional Review Board Approval, 60 patients (mean age, 59.1 years; M:F = 35:25) and 57 weight-matched patients (mean age, 52.3 years, M:F = 25:32) were scanned using a weight-adjusted AEC and non-weight-adjusted AEC, respectively on a 64-slice multidetector CT with a 0.984:1 pitch, 0.5 second rotation time, 40 mm table feed/rotation, and 2.5 mm section thickness. Patients were categorized into 3 weight categories; < 60 kg (n = 17), 60-90 kg (n = 52), and > 90 kg (n = 48). Patient weights, scanning parameters, CT dose index volumes (CTDIvol) and dose length product (DLP) were recorded, while effective dose (ED) was estimated. Image noise was measured in the descending thoracic aorta. Data were analyzed using a standard statistical package (SAS/STAT) (Version 9.1, SAS institute Inc, Cary, NC). Compared to the non-weight-adjusted AEC, the weight-adjusted AEC technique resulted in an average decrease of 29% in CTDIvol and a 27% effective dose reduction (p < 0.0001). With weight-adjusted AEC, the CTDIvol decreased to 15.8, 15.9, and 27.3 mGy for the < 60, 60-90 and > 91 kg weight groups, respectively, compared to 20.3, 27.9 and 32.8 mGy, with non-weight-adjusted AEC. No significant difference was observed for objective image noise between the chest CT acquired with the non-weight-adjusted (15.0 +/- 3.1) and weight-adjusted (16.1 +/- 5.6) AEC techniques (p > 0.05). The results of this study suggest that AEC should be tailored according to patient weight. Without weight-based adjustment of AEC, patients are exposed to a 17 - 43% higher radiation-dose from a chest CT.

  8. CT dose modulation using automatic exposure control in whole-body PET/CT: effects of scout imaging direction and arm positioning.

    PubMed

    Inoue, Yusuke; Nagahara, Kazunori; Kudo, Hiroko; Itoh, Hiroyasu

    2018-01-01

    Automatic exposure control (AEC) modulates tube current and consequently X-ray exposure in CT. We investigated the behavior of AEC systems in whole-body PET/CT. CT images of a whole-body phantom were acquired using AEC on two scanners from different manufactures. The effects of scout imaging direction and arm positioning on dose modulation were evaluated. Image noise was assessed in the chest and upper abdomen. On one scanner, AEC using two scout images in the posteroanterior (PA) and lateral (Lat) directions provided relatively constant image noise along the z-axis with the arms at the sides. Raising the arms increased tube current in the head and neck and decreased it in the body trunk. Image noise increased in the upper abdomen, suggesting excessive reduction in radiation exposure. AEC using the PA scout alone strikingly increased tube current and reduced image noise in the shoulder. Raising the arms did not substantially influence dose modulation and decreased noise in the abdomen. On the other scanner, AEC using the PA scout alone or Lat scout alone resulted in similar dose modulation. Raising the arms increased tube current in the head and neck and decreased it in the trunk. Image noise was higher in the upper abdomen than in the middle and lower chest, and was not influenced by arm positioning. CT dose modulation using AEC may vary greatly depending on scout direction. Raising the arms tended to decrease radiation exposure; however, the effect depends on scout direction and the AEC system.

  9. Strongyloidiasis Epidemiology and Treatment Response in Patients with HIV Infection

    PubMed Central

    Cortes-Penfield, Nicolas; Moore, Cody; Arduino, Roberto; Serpa, Jose

    2017-01-01

    Abstract Background We sought to characterize the epidemiology of HIV and S. stercoralis coinfection in an urban HIV cohort, and to investigate the effect of S. stercoralis infection on HIV virologic control and immune recovery. Methods We reviewed the medical records of all HIV-infected patients diagnosed with strongyloidiasis who received care at Thomas Street Health Center (Houston, TX) between 2000 and 2015. For each case we included up to two matched HIV-infected patients without strongyloidiasis (controls). Matching was based on age, sex, ethnicity, baseline CD4 percentage, and HIV viral load at the time of strongyloidiasis diagnosis in the case patient. We recorded patient demographics, comorbidities, CD4 count and percentage, HIV viral load, and absolute eosinophilia count (AEC) at the time of HIV diagnosis, strongyloidiasis diagnosis, and six and twelve months after ivermectin treatment. Results We identified 15 cases of HIV and S.stercoralis coinfection; 13 had at least one available matched control. The mean age of coinfected patients was 45; all were Hispanic, 84.6% were male, and the mean CD4 nadir was 146 cells/ul. At the time of strongyloidiasis diagnosis, the mean CD4 count was 460 cells/ul, HIV RNA viral load 2.07 logs/ml, and AEC was 1,360 cells/μL. At 6 and 12 months after treatment, CD4 counts were 514 and 464 cells/μL, HIV RNA viral loads 1.78 and 2.31 log/mL, and AECs 319 and 362 cells/μL, respectively. Although CD4 counts increased 6 months after treatment, they returned to baseline levels at 12 months; neither change achieved statistical significance. The reduction in AECs after ivermectin treatment was statistically significant (P < 0.001). Matched controls without S.stercoralis had lower AECs at baseline, 6 months, and 12 months; otherwise, there were no differences between cases and controls. Conclusion Strongyloidiasis treatment in HIV-infected patients led to normalization of the AEC at 6 months in most cases, but AECs remained higher than in control patients. Persistently elevated AECs may suggest treatment failure or reinfection. Our study was unable to identify any effect of S. stercoralis infection or treatment on HIV virologic suppression or immunologic recovery; larger studies are warranted to investigate the effect of strongyloidiasis on HIV disease. Disclosures All authors: No reported disclosures.

  10. Use of automatic exposure control in multislice computed tomography of the coronaries: comparison of 16‐slice and 64‐slice scanner data with conventional coronary angiography

    PubMed Central

    Deetjen, Anja; Möllmann, Susanne; Conradi, Guido; Rolf, Andreas; Schmermund, Axel; Hamm, Christian W; Dill, Thorsten

    2007-01-01

    Objective To evaluate the radiation‐dose‐reduction potential of automatic exposure control (AEC) in 16‐slice and 64‐slice multislice computed tomography (MSCT) of the coronary arteries (computed tomography angiography, CTA) in patients. The rapid growth in MSCT CTA emphasises the necessity of adjusting technique factors to reduce radiation dose exposure. Design A retrospective data analysis was performed for 154 patients who had undergone MSCT CTA. Group 1 (n = 56) had undergone 16‐slice MSCT without AEC, and group 2 (n = 51), with AEC. In group 1, invasive coronary angiography (ICA) had been performed in addition. Group 3 (n = 47) had been examined using a 64‐slice scanner (with AEC, without ECG‐triggered tube current modulation). Results In group 1, the mean (SD) effective dose (ED) for MSCT CTA was 9.76 (1.84) mSv and for ICA it was 2.6 (1.27) mSv. In group 2, the mean ED for MSCT CTA was 5.83 (1.73) mSv, which signifies a 42.8% dose reduction for CTA by the use of AEC. In comparison to ICA, MSCT CTA without AEC shows a 3.8‐fold increase in radiation dose, and the radiation dose of CTA with AEC was increased by a factor of 1.9. In group 3, the mean ED for MSCT CTA was 13.58 (2.80) mSV. Conclusions This is the first study to show the significant dose‐reduction potential (42.8%) of AEC in MSCT CTA in patients. This relatively new technique can be used to optimise the radiation dose levels in MSCT CTA. PMID:17395667

  11. miR-34 miRNAs Regulate Cellular Senescence in Type II Alveolar Epithelial Cells of Patients with Idiopathic Pulmonary Fibrosis

    PubMed Central

    Disayabutr, Supparerk; Kim, Eun Kyung; Cha, Seung-Ick; Green, Gary; Naikawadi, Ram P.; Jones, Kirk D.; Golden, Jeffrey A.; Schroeder, Aaron; Matthay, Michael A.; Kukreja, Jasleen; Erle, David J.; Collard, Harold R.; Wolters, Paul J.

    2016-01-01

    Pathologic features of idiopathic pulmonary fibrosis (IPF) include genetic predisposition, activation of the unfolded protein response, telomere attrition, and cellular senescence. The mechanisms leading to alveolar epithelial cell (AEC) senescence are poorly understood. MicroRNAs (miRNAs) have been reported as regulators of cellular senescence. Senescence markers including p16, p21, p53, and senescence-associated β-galactosidase (SA-βgal) activity were measured in type II AECs from IPF lungs and unused donor lungs. miRNAs were quantified in type II AECs using gene expression arrays and quantitative RT-PCR. Molecular markers of senescence (p16, p21, and p53) were elevated in IPF type II AECs. SA-βgal activity was detected in a greater percentage in type II AECs isolated from IPF patients (23.1%) compared to patients with other interstitial lung diseases (1.2%) or normal controls (0.8%). The relative levels of senescence-associated miRNAs miR-34a, miR-34b, and miR-34c, but not miR-20a, miR-29c, or miR-let-7f were significantly higher in type II AECs from IPF patients. Overexpression of miR-34a, miR-34b, or miR-34c in lung epithelial cells was associated with higher SA-βgal activity (27.8%, 35.1%, and 38.2%, respectively) relative to control treated cells (8.8%). Targets of miR-34 miRNAs, including E2F1, c-Myc, and cyclin E2, were lower in IPF type II AECs. These results show that markers of senescence are uniquely elevated in IPF type II AECs and suggest that the miR-34 family of miRNAs regulate senescence in IPF type II AECs. PMID:27362652

  12. NOVEL FLOW DEVICE

    DOEpatents

    Brockwell, R.E.

    1963-11-26

    The design of hollow, porous-walled articles is presented. By this invention a hollow, porous-walled article is made by stacking thin, centrally apertured plates having grooves extending from their central aperture to their periphery. (AEC)

  13. Efficient multichannel acoustic echo cancellation using constrained tap selection schemes in the subband domain

    NASA Astrophysics Data System (ADS)

    Desiraju, Naveen Kumar; Doclo, Simon; Wolff, Tobias

    2017-12-01

    Acoustic echo cancellation (AEC) is a key speech enhancement technology in speech communication and voice-enabled devices. AEC systems employ adaptive filters to estimate the acoustic echo paths between the loudspeakers and the microphone(s). In applications involving surround sound, the computational complexity of an AEC system may become demanding due to the multiple loudspeaker channels and the necessity of using long filters in reverberant environments. In order to reduce the computational complexity, the approach of partially updating the AEC filters is considered in this paper. In particular, we investigate tap selection schemes which exploit the sparsity present in the loudspeaker channels for partially updating subband AEC filters. The potential for exploiting signal sparsity across three dimensions, namely time, frequency, and channels, is analyzed. A thorough analysis of different state-of-the-art tap selection schemes is performed and insights about their limitations are gained. A novel tap selection scheme is proposed which overcomes these limitations by exploiting signal sparsity while not ignoring any filters for update in the different subbands and channels. Extensive simulation results using both artificial as well as real-world multichannel signals show that the proposed tap selection scheme outperforms state-of-the-art tap selection schemes in terms of echo cancellation performance. In addition, it yields almost identical echo cancellation performance as compared to updating all filter taps at a significantly reduced computational cost.

  14. Improvement of axial excitation confinement in temporal focusing-based multiphoton microscopy via spatially modulated illumination

    NASA Astrophysics Data System (ADS)

    Chang, Chia-Yuan; Chen, Shean-Jen

    2017-02-01

    Conventional temporal focusing-based multiphoton excitation microscopy (TFMPEM) can offer widefield optical sectioning with an axial excitation confinement (AEC) of a few microns. Herein, a developed TFMPEM with a digital micromirror device (DMD), acting as the blazed grating for light spatial dispersion and simultaneous patterned illumination, has been extended to implement spatially modulated illumination at structured frequency and orientation. By implementing the spatially modulated illumination, the beam coverage at the back-focal aperture of the objective lens can be increased. As a result, the AEC can be condensed from 3.0 μm to 1.5 μm in full width at half maximum for a 2-fold enhancement. Furthermore, by using HiLo microscopy with two structured illuminations at the same spatial frequency but different orientation, biotissue images according to the structured illumination with condensed AEC is obviously superior in contrast and scattering suppression.

  15. Configuration of automatic exposure control on mammography units for computed radiography to match patient dose of screen film systems

    NASA Astrophysics Data System (ADS)

    Yang, Chang-Ying Joseph; Huang, Weidong

    2009-02-01

    Computed radiography (CR) is considered a drop-in addition or replacement for traditional screen-film (SF) systems in digital mammography. Unlike other technologies, CR has the advantage of being compatible with existing mammography units. One of the challenges, however, is to properly configure the automatic exposure control (AEC) on existing mammography units for CR use. Unlike analogue systems, the capture and display of digital CR images is decoupled. The function of AEC is changed from ensuring proper and consistent optical density of the captured image on film to balancing image quality with patient dose needed for CR. One of the preferences when acquiring CR images under AEC is to use the same patient dose as SF systems. The challenge is whether the existing AEC design and calibration process-most of them proprietary from the X-ray systems manufacturers and tailored specifically for SF response properties-can be adapted for CR cassettes, in order to compensate for their response and attenuation differences. This paper describes the methods for configuring the AEC of three different mammography units models to match the patient dose used for CR with those that are used for a KODAK MIN-R 2000 SF System. Based on phantom test results, these methods provide the dose level under AEC for the CR systems to match with the dose of SF systems. These methods can be used in clinical environments that require the acquisition of CR images under AEC at the same dose levels as those used for SF systems.

  16. A20 Deficiency in Lung Epithelial Cells Protects against Influenza A Virus Infection

    PubMed Central

    Vereecke, Lars; Mc Guire, Conor; Sze, Mozes; Schuijs, Martijn J.; Willart, Monique; Itati Ibañez, Lorena; Hammad, Hamida; Lambrecht, Bart N.; Beyaert, Rudi; Saelens, Xavier; van Loo, Geert

    2016-01-01

    A20 negatively regulates multiple inflammatory signalling pathways. We here addressed the role of A20 in club cells (also known as Clara cells) of the bronchial epithelium in their response to influenza A virus infection. Club cells provide a niche for influenza virus replication, but little is known about the functions of these cells in antiviral immunity. Using airway epithelial cell-specific A20 knockout (A20AEC-KO) mice, we show that A20 in club cells critically controls innate immune responses upon TNF or double stranded RNA stimulation. Surprisingly, A20AEC-KO mice are better protected against influenza A virus challenge than their wild type littermates. This phenotype is not due to decreased viral replication. Instead host innate and adaptive immune responses and lung damage are reduced in A20AEC-KO mice. These attenuated responses correlate with a dampened cytotoxic T cell (CTL) response at later stages during infection, indicating that A20AEC-KO mice are better equipped to tolerate Influenza A virus infection. Expression of the chemokine CCL2 (also named MCP-1) is particularly suppressed in the lungs of A20AEC-KO mice during later stages of infection. When A20AEC-KO mice were treated with recombinant CCL2 the protective effect was abrogated demonstrating the crucial contribution of this chemokine to the protection of A20AEC-KO mice to Influenza A virus infection. Taken together, we propose a mechanism of action by which A20 expression in club cells controls inflammation and antiviral CTL responses in response to influenza virus infection. PMID:26815999

  17. ELECTRICAL COIL STRUCTURE

    DOEpatents

    Baker, W.R.; Hartwig, A.

    1962-09-25

    A compactly wound electrical coil is designed for carrying intense pulsed currents such as are characteristic of controlled thermonuclear reaction devices. A flat strip of conductor is tightly wound in a spiral with a matching flat strip of insulator. To provide for a high fluid coolant flow through the coil with minimum pumping pressure, a surface of the conductor is scored with parallel transverse grooves which form short longitudinal coolant pasaages when the conductor is wound in the spiral configuration. Owing to this construction, the coil is extremely resistant to thermal and magnetic shock from sudden high currents. (AEC)

  18. NUCLEAR REACTORS

    DOEpatents

    Koch, L.J.; Rice, R.E. Jr.; Denst, A.A.; Rogers, A.J.; Novick, M.

    1961-12-01

    An active portion assembly for a fast neutron reactor is described wherein physical distortions resulting in adverse changes in the volume-to-mass ratio are minimized. A radially expandable locking device is disposed within a cylindrical tube within each fuel subassembly within the active portion assembly, and clamping devices expandable toward the center of the active portion assembly are disposed around the periphery thereof. (AEC)

  19. Low-dose computed tomography scans with automatic exposure control for patients of different ages undergoing cardiac PET/CT and SPECT/CT.

    PubMed

    Yang, Ching-Ching; Yang, Bang-Hung; Tu, Chun-Yuan; Wu, Tung-Hsin; Liu, Shu-Hsin

    2017-06-01

    This study aimed to evaluate the efficacy of automatic exposure control (AEC) in order to optimize low-dose computed tomography (CT) protocols for patients of different ages undergoing cardiac PET/CT and single-photon emission computed tomography/computed tomography (SPECT/CT). One PET/CT and one SPECT/CT were used to acquire CT images for four anthropomorphic phantoms representative of 1-year-old, 5-year-old and 10-year-old children and an adult. For the hybrid systems investigated in this study, the radiation dose and image quality of cardiac CT scans performed with AEC activated depend mainly on the selection of a predefined image quality index. Multiple linear regression methods were used to analyse image data from anthropomorphic phantom studies to investigate the effects of body size and predefined image quality index on CT radiation dose in cardiac PET/CT and SPECT/CT scans. The regression relationships have a coefficient of determination larger than 0.9, indicating a good fit to the data. According to the regression models, low-dose protocols using the AEC technique were optimized for patients of different ages. In comparison with the standard protocol with AEC activated for adult cardiac examinations used in our clinical routine practice, the optimized paediatric protocols in PET/CT allow 32.2, 63.7 and 79.2% CT dose reductions for anthropomorphic phantoms simulating 10-year-old, 5-year-old and 1-year-old children, respectively. The corresponding results for cardiac SPECT/CT are 8.4, 51.5 and 72.7%. AEC is a practical way to reduce CT radiation dose in cardiac PET/CT and SPECT/CT, but the AEC settings should be determined properly for optimal effect. Our results show that AEC does not eliminate the need for paediatric protocols and CT examinations using the AEC technique should be optimized for paediatric patients to reduce the radiation dose as low as reasonably achievable.

  20. FLOWMETER

    DOEpatents

    November, G.S.; Schute, F.

    1962-02-20

    A fluid flowmeter is designed in which a standing pressure wave is established. The amplitude of this standing wave is a function of the fluid flow rate so that pressure sensing devices may be used to indicate fluid flow and variations thereof. (AEC)

  1. CT dose reduction using Automatic Exposure Control and iterative reconstruction: A chest paediatric phantoms study.

    PubMed

    Greffier, Joël; Pereira, Fabricio; Macri, Francesco; Beregi, Jean-Paul; Larbi, Ahmed

    2016-04-01

    To evaluate the impact of Automatic Exposure Control (AEC) on radiation dose and image quality in paediatric chest scans (MDCT), with or without iterative reconstruction (IR). Three anthropomorphic phantoms representing children aged one, five and 10-year-old were explored using AEC system (CARE Dose 4D) with five modulation strength options. For each phantom, six acquisitions were carried out: one with fixed mAs (without AEC) and five each with different modulation strength. Raw data were reconstructed with Filtered Back Projection (FBP) and with two distinct levels of IR using soft and strong kernels. Dose reduction and image quality indices (Noise, SNR, CNR) were measured in lung and soft tissues. Noise Power Spectrum (NPS) was evaluated with a Catphan 600 phantom. The use of AEC produced a significant dose reduction (p<0.01) for all anthropomorphic sizes employed. According to the modulation strength applied, dose delivered was reduced from 43% to 91%. This pattern led to significantly increased noise (p<0.01) and reduced SNR and CNR (p<0.01). However, IR was able to improve these indices. The use of AEC/IR preserved image quality indices with a lower dose delivered. Doses were reduced from 39% to 58% for the one-year-old phantom, from 46% to 63% for the five-year-old phantom, and from 58% to 74% for the 10-year-old phantom. In addition, AEC/IR changed the patterns of NPS curves in amplitude and in spatial frequency. In chest paediatric MDCT, the use of AEC with IR allows one to obtain a significant dose reduction while maintaining constant image quality indices. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  2. Hypoglycemic and anti-lipemic effects of the aqueous extract from Cissus sicyoides

    PubMed Central

    Viana, Glauce SB; Medeiros, Ana Carolina C; Lacerda, Ana Michelle R; Leal, L Kalyne AM; Vale, Tiago G; Matos, F José de Abreu

    2004-01-01

    Background Cissus sicyoides (Vitaceae) is a medicinal plant popularly known in Brazil as "cipó-pucá, anil-trepador, cortina, and insulina". The plant is used in several diseases, including rheumatism, epilepsy, stroke and also in the treatment of diabetes. In the present work, we studied the hypoglycemic and anti-lipemic effects of the aqueous extract prepared from fresh leaves of the plant (AECS), in the model of alloxan-induced diabetes in rats. In addition, hepatic enzyme levels were also determined. Results Results showed that the daily treatment of diabetic rats with AECS for 7 days (100 and 200 mg/kg, p.o.) significantly decreased blood glucose levels in 25 and 22% respectively, as compared to the same groups before AECS treatment. No significant changes were seen in control diabetic rats before (48 h after alloxan administration) and after distilled water treatment. While no changes were seen in total cholesterol levels, a significant decrease was observed in plasma triglyceride levels, in the alloxan-induced diabetic rats after AECS treatment with both doses, as compared to the same groups before treatment. Significant decreases in blood glucose (25%) and triglyceride levels (48%) were also observed in the alloxan-induced diabetic rats after 4 days treatment with AECS (200 mg/kg, p.o.). Aspartate (AST) and alanine (ALT) aminotransferases levels, in diabetic controls and AECS-treated rats, were in the range of reference values presented by normal rats. Conclusions The results justify the popular use of C. sicyoides, pointing out to the potential benefit of the plant aqueous extract (AECS) in alternative medicine, in the treatment of type 2 diabetes mellitus. PMID:15182373

  3. Alternating current line-filter based on electrochemical capacitor utilizing template-patterned graphene.

    PubMed

    Wu, Zhenkun; Li, Liyi; Lin, Ziyin; Song, Bo; Li, Zhuo; Moon, Kyoung-Sik; Wong, Ching-Ping; Bai, Shu-Lin

    2015-06-17

    Aluminum electrolytic capacitors (AECs) are widely used for alternating current (ac) line-filtering. However, their bulky size is becoming more and more incompatible with the rapid development of portable electronics. Here we report a scalable process to fabricate miniaturized graphene-based ac line-filters on flexible substrates at room temperature. In this work, graphene oxide (GO) is reduced by patterned metal interdigits at room temperature and used directly as the electrode material. The as-fabricated device shows a phase angle of -75.4° at 120 Hz with a specific capacitance of 316 µF/cm(2) and a RC time constant of 0.35 ms. In addition, it retains 97.2% of the initial capacitance after 10000 charge/discharge cycles. These outstanding performance characteristics of our device demonstrate its promising to replace the conventional AECs for ac line filtering.

  4. Investigation of the characteristics of Automatic Exposure Control (AEC) of a Computed Tomography (CT) scanner by utilising cylindrical and anthropomorphic phantoms

    NASA Astrophysics Data System (ADS)

    Rulaidi, W. E. P.; Huri, M. S. N.; Ng, K. H.

    2017-05-01

    One method to optimise the use of x-rays in CT and hence a reduction in patient dose is the application of automatic exposure control (AEC). This study measured the effective mAs, image noise and volume CT dose index (CTDIvol) as the result of changing the AEC index on a Siemens Somatom Definition 64 slices dual source CT scanner. The scans were performed on four phantoms of different geometries, namely the 16 and 32 cm cylindrical CTDI phantoms and two anthropomorphic phantoms, RANDO (20 cm effective diameter) and ATOM (19.8 cm effective diameter). Results showed that the effective mAs increased with increasing tube potential (kVp) and Quality Reference mAs (QRM), therefore increasing CTDIvol while reducing image noise. Meanwhile, no changes of radiation dose and image noise were observed when the pitch was increased. However, for the largest phantom (32 cm effective diameter), a constant effective mAs was found between 120 and 140 kVp. The same trend was also found with increasing QRM from 300 mAs to 400 mAs suggesting a certain limitation of the AEC has been reached. In conclusion, this study showed that AEC is affected by kVp and QRM but not by pitch selection. Further work is required to quantify the characteristics of the AEC system in relation to the mentioned parameters for better optimisation.

  5. 28 CFR 79.33 - Proof of participation onsite during a period of atmospheric nuclear testing.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... number; (iv) The site at which the claimant participated in the atmospheric detonation of a nuclear... atmospheric detonation of a nuclear device. If the facts gathered by the DoD are insufficient to establish the... claimant was present onsite during the atmospheric detonation of a nuclear device as an employee of the AEC...

  6. Radio Ranging Device

    DOEpatents

    Gratian, J. W.; Gratian, A. C.; Crane, H. R.; Bourns, M. E.; Nieset, R. T.

    1961-04-18

    A super-generative radar system is described as having alternate phases of transmission and reception and is adapted to transmit for unequal durations in the absence of receiving energy and for equal and longer durations when energy of proper phase is received. (AEC)

  7. Ultrahigh-rate supercapacitors based on eletrochemically reduced graphene oxide for ac line-filtering.

    PubMed

    Sheng, Kaixuan; Sun, Yiqing; Li, Chun; Yuan, Wenjing; Shi, Gaoquan

    2012-01-01

    The recent boom in multifunction portable electronic equipments requires the development of compact and miniaturized electronic circuits with high efficiencies, low costs and long lasting time. For the operation of most line-powered electronics, alternating current (ac) line-filters are used to attenuate the leftover ac ripples on direct current (dc) voltage busses. Today, aluminum electrolytic capacitors (AECs) are widely applied for this purpose. However, they are usually the largest components in electronic circuits. Replacing AECs by more compact capacitors will have an immense impact on future electronic devices. Here, we report a double-layer capacitor based on three-dimensional (3D) interpenetrating graphene electrodes fabricated by electrochemical reduction of graphene oxide (ErGO-DLC). At 120-hertz, the ErGO-DLC exhibited a phase angle of -84 degrees, a specific capacitance of 283 microfaradays per centimeter square and a resistor-capacitor (RC) time constant of 1.35 milliseconds, making it capable of replacing AECs for the application of 120-hertz filtering.

  8. Ultrahigh-rate supercapacitors based on eletrochemically reduced graphene oxide for ac line-filtering

    NASA Astrophysics Data System (ADS)

    Sheng, Kaixuan; Sun, Yiqing; Li, Chun; Yuan, Wenjing; Shi, Gaoquan

    2012-02-01

    The recent boom in multifunction portable electronic equipments requires the development of compact and miniaturized electronic circuits with high efficiencies, low costs and long lasting time. For the operation of most line-powered electronics, alternating current (ac) line-filters are used to attenuate the leftover ac ripples on direct current (dc) voltage busses. Today, aluminum electrolytic capacitors (AECs) are widely applied for this purpose. However, they are usually the largest components in electronic circuits. Replacing AECs by more compact capacitors will have an immense impact on future electronic devices. Here, we report a double-layer capacitor based on three-dimensional (3D) interpenetrating graphene electrodes fabricated by electrochemical reduction of graphene oxide (ErGO-DLC). At 120-hertz, the ErGO-DLC exhibited a phase angle of -84 degrees, a specific capacitance of 283 microfaradays per centimeter square and a resistor-capacitor (RC) time constant of 1.35 milliseconds, making it capable of replacing AECs for the application of 120-hertz filtering.

  9. Ultrahigh-rate supercapacitors based on eletrochemically reduced graphene oxide for ac line-filtering

    PubMed Central

    Sheng, Kaixuan; Sun, Yiqing; Li, Chun; Yuan, Wenjing; Shi, Gaoquan

    2012-01-01

    The recent boom in multifunction portable electronic equipments requires the development of compact and miniaturized electronic circuits with high efficiencies, low costs and long lasting time. For the operation of most line-powered electronics, alternating current (ac) line-filters are used to attenuate the leftover ac ripples on direct current (dc) voltage busses. Today, aluminum electrolytic capacitors (AECs) are widely applied for this purpose. However, they are usually the largest components in electronic circuits. Replacing AECs by more compact capacitors will have an immense impact on future electronic devices. Here, we report a double-layer capacitor based on three-dimensional (3D) interpenetrating graphene electrodes fabricated by electrochemical reduction of graphene oxide (ErGO-DLC). At 120-hertz, the ErGO-DLC exhibited a phase angle of −84 degrees, a specific capacitance of 283 microfaradays per centimeter square and a resistor-capacitor (RC) time constant of 1.35 milliseconds, making it capable of replacing AECs for the application of 120-hertz filtering. PMID:22355759

  10. Effects of AEC chamber selection on patient dose and image quality.

    PubMed

    Hawking, Nancy; Elmore, Angie

    2009-01-01

    To determine whether manipulation of the standard automatic exposure control (AEC) chamber selections reduces the patient's entrance skin exposure (ESE) without compromising image quality. Data for density and radiation dose were gathered at 2 clinical locations by exposing abdomen and pelvis phantoms to radiation using 3 AEC chamber selection configurations. ESE (skin dose) was measured using a multipurpose dosimeter. The experiment included both film-screen and computed radiography (CR) systems. For both phantoms, using the 2 outside chambers resulted in the lowest dose on the film-screen and CR systems. In general, optical density (OD) and exposure indicator (EI) remained within acceptable ranges and image quality was maintained using this chamber configuration. Using only the center chamber resulted in the highest dose increases and lowest image quality for film-screen and CR systems. When performing anteroposterior (AP) abdomen and AP pelvis examinations, radiographers can reduce patients' ESE and maintain image quality by selecting the 2 outside AEC chambers. Further research on AEC chamber selection should be conducted for additional anatomical regions.

  11. [Advances in research on automatic exposure control of mammography system].

    PubMed

    Wang, Guoyi; Ye, Chengfu; Wu, Haiming; Wang, Tainfu; Zhang, Hong

    2014-12-01

    Mammography imaging is one of the most demanding imaging modalities from the point of view of the bal- ance between image quality (the visibility of small size and/or low contrast structures) and dose (screening of many asymptomatic people). Therefore, since the introduction of the first dedicated mammographic units, many efforts have been directed to seek the best possible image quality while minimizing patient dose. The performance of auto- matic exposure control (AEC) is the manifestation of this demand. The theory of AEC includes exposure detection and optimization and also involves some accomplished methodology. This review presents the development and present situa- tion of spectrum optimization, detector evolution, and the way how to accomplish and evaluate AEC methods.

  12. FRICTION-FREE BALANCE

    DOEpatents

    Carson, N.J. Jr.; Ostrander, H.W.; Munter, C.N.

    1964-03-01

    A weighing device having a load-supporting vertical shaft buoyed up by mutually repellant magnets is described. The shaft is aligned by an air bearing and has an air gage to sense vertical displacement caused by weights placed on the top end of the shaft. (AEC)

  13. The adenylate energy charge as a new and useful indicator of capture stress in chondrichthyans.

    PubMed

    Guida, Leonardo; Walker, Terence I; Reina, Richard D

    2016-02-01

    Quantifying the physiological stress response of chondrichthyans to capture has assisted the development of fishing practices conducive to their survival. However, currently used indicators of stress show significant interspecific and intraspecific variation in species' physiological responses and tolerances to capture. To improve our understanding of chondrichthyan stress physiology and potentially reduce variation when quantifying the stress response, we investigated the use of the adenylate energy charge (AEC); a measure of available metabolic energy. To determine tissues sensitive to metabolic stress, we extracted samples of the brain, heart, liver, white muscle and blood from gummy sharks (Mustelus antarcticus) immediately following gillnet capture and after 3 h recovery under laboratory conditions. Capture caused significant declines in liver, white muscle and blood AEC, whereas no decline was detected in the heart and brain AEC. Following 3 h of recovery from capture, the AEC of the liver and blood returned to "unstressed" levels (control values) whereas white muscle AEC was not significantly different to that immediately after capture. Our results show that the liver is most sensitive to metabolic stress and white muscle offers a practical method to sample animals non-lethally for determination of the AEC. The AEC is a highly informative indicator of stress and unlike current indicators, it can directly measure the change in available energy and thus the metabolic stress experienced by a given tissue. Cellular metabolism is highly conserved across organisms and, therefore, we think the AEC can also provide a standardised form of measuring capture stress in many chondrichthyan species.

  14. [Effects of Tetrandrine Prenatal Intervention on Alveolar Epithelial Cells Type I Differentiation in Rat Model of Nitrofen-induced Congenital Diaphragmatic Hernia].

    PubMed

    Xiao, Bin; Xu, Chang; Liu, Min; Ji, Yi; Yang Li-xun; Li, Tai-ming; Jiang, Jun; He, Tao-zhen

    2016-03-01

    To investigate the effects of Tetrandrine (TET) prenatal intervention on the differentiation of alveolar epithelial cells type I (AEC I) in rat model of Nitrofen-induced congenital diaphragmatic hernia (CDH). Timed-pregnant Sprague-Dawley rats were divided into three groups, namely control, CDH and TET group on day 9.5 of gestation. The rats in TET group and CDH group were given 125 mg of Nitrofen by gavage one time, while the rats in control group were given the same dose of seed fat. After that, the rats in TET group was given 30 mg/kg of TET by gavage once a day for three days from day 18.5 of gestation, while the rats in CDH and control group were given the same dose of normal saline. On day 21.5 of gestation, all fetuses were delivered by cesarean, the lungs of fetuses were histologically evaluated by microscope and electron microscope. The expressions of type I cell-specific protein (RT140) and thyroid transcription factor 1 (TTF1) in alveolar fluid content were analyzed by RT-PCR and immunohistochemistry staining. To detect the number of AEC I and AEC II of each group by transmission electron microscopy and calculate the percentage of AEC I and AEC II (I/II%). The microscope and electron microscope study found the lungs of fetuses in CDH group showed marked hypoplasia, in contrast to the improvement of hypoplasia in TET fetuses. The pulmonary alveolar area had significant difference statistically (P < 0.01) in each group, which present as control > TET > CDH. I/II% had significant difference statistically (P < 0.01) in each group, which present as control > TET > CDH. The expression level of TTF1 was up-regulated in both CDH and TET groups, and it was higher in CDH group (P < 0.01). The expression level of RT140 were down-regulated in CDH and TET groups, which was lower in CDH group (P < 0.01). The development of AEC I was interfered in CDH rat model, TET prenatal treatment could improve the lung development of CDH.

  15. A three-dimensional culture system using alginate hydrogel prolongs hatched cattle embryo development in vitro.

    PubMed

    Zhao, Shuan; Liu, Zhen-Xing; Gao, Hui; Wu, Yi; Fang, Yuan; Wu, Shuai-Shuai; Li, Ming-Jie; Bai, Jia-Hua; Liu, Yan; Evans, Alexander; Zeng, Shen-Ming

    2015-07-15

    No successful method exists to maintain the three-dimensional architecture of hatched embryos in vitro. Alginate, a linear polysaccharide derived from brown algae, has characteristics that make it an ideal material as a three-dimensional (3D) extracellular matrix for in vitro cell, tissue, or embryo culture. In this study, alginate hydrogel was used for IVC of posthatched bovine embryos to observe their development under the 3D system. In vitro-fertilized and parthenogenetically activated posthatched bovine blastocysts were cultured in an alginate encapsulation culture system (AECS), an alginate overlay culture system (AOCS), or control culture system. After 18 days of culture, the survival rate of embryos cultured in AECS was higher than that in the control group (P < 0.05), and the embryos were expanded and elongated in AECS with the maximal length of 1.125 mm. When the AECS shrinking embryos were taken out of the alginate beads on Day 18 and cultured in the normal culture system, 9.09% of them attached to the bottoms of the plastic wells and grew rapidly, with the largest area of an attached embryo being 66.00 mm(2) on Day 32. The embryos cultured in AOCS developed monovesicular or multivesicular morphologies. Total cell number of the embryos cultured in AECS on Day 19 was significantly higher than that of embryos on Day 8. Additionally, AECS and AOCS supported differentiation of the embryonic cells. Binuclear cells were visible in Day-26 adherent embryos, and the messenger RNA expression patterns of Cdx2 and Oct4 in AOCS-cultured embryos were similar to those in vivo embryos, whereas IFNT and ISG15 messenger RNA were still expressed in Day-26 and Day-32 prolong-cultured embryos. In conclusion, AECS and AOCS did support cell proliferation, elongation, and differentiation of hatched bovine embryos during prolonged IVC. The culture system will be useful to further investigate the molecular mechanisms controlling ruminant embryo elongation and implantation. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Computed tomography automatic exposure control techniques in 18F-FDG oncology PET-CT scanning.

    PubMed

    Iball, Gareth R; Tout, Deborah

    2014-04-01

    Computed tomography (CT) automatic exposure control (AEC) systems are now used in all modern PET-CT scanners. A collaborative study was undertaken to compare AEC techniques of the three major PET-CT manufacturers for fluorine-18 fluorodeoxyglucose half-body oncology imaging. An audit of 70 patients was performed for half-body CT scans taken on a GE Discovery 690, Philips Gemini TF and Siemens Biograph mCT (all 64-slice CT). Patient demographic and dose information was recorded and image noise was calculated as the SD of Hounsfield units in the liver. A direct comparison of the AEC systems was made by scanning a Rando phantom on all three systems for a range of AEC settings. The variation in dose and image quality with patient weight was significantly different for all three systems, with the GE system showing the largest variation in dose with weight and Philips the least. Image noise varied with patient weight in Philips and Siemens systems but was constant for all weights in GE. The z-axis mA profiles from the Rando phantom demonstrate that these differences are caused by the nature of the tube current modulation techniques applied. The mA profiles varied considerably according to the AEC settings used. CT AEC techniques from the three manufacturers yield significantly different tube current modulation patterns and hence deliver different doses and levels of image quality across a range of patient weights. Users should be aware of how their system works and of steps that could be taken to optimize imaging protocols.

  17. ROTATING PLASMA DEVICE

    DOEpatents

    Boyer, K.; Hammel, J.E.; Longmire, C.L.; Nagle, D.E.; Ribe, F.L.; Tuck, J.L.

    1961-10-24

    ABS>A method and device are described for obtaining fusion reactions. The basic concept is that of using crossed electric and magnetic fields to induce a plasma rotation in which the ionized particles follow a circumferential drift orbit on wldch a cyclotron mode of motion is superimposed, the net result being a cycloidal motion about the axis of symmetry. The discharge tube has a radial electric field and a longitudinal magnetic field. Mirror machine geometry is utilized. The device avoids reliance on the pinch effect and its associated instability problems. (AEC)

  18. Female gonadal shielding with automatic exposure control increases radiation risks.

    PubMed

    Kaplan, Summer L; Magill, Dennise; Felice, Marc A; Xiao, Rui; Ali, Sayed; Zhu, Xiaowei

    2018-02-01

    Gonadal shielding remains common, but current estimates of gonadal radiation risk are lower than estimated risks to colon and stomach. A female gonadal shield may attenuate active automatic exposure control (AEC) sensors, resulting in increased dose to colon and stomach as well as to ovaries outside the shielded area. We assess changes in dose-area product (DAP) and absorbed organ dose when female gonadal shielding is used with AEC for pelvis radiography. We imaged adult and 5-year-old equivalent dosimetry phantoms using pelvis radiograph technique with AEC in the presence and absence of a female gonadal shield. We recorded DAP and mAs and measured organ absorbed dose at six internal sites using film dosimetry. Female gonadal shielding with AEC increased DAP 63% for the 5-year-old phantom and 147% for the adult phantom. Absorbed organ dose at unshielded locations of colon, stomach and ovaries increased 21-51% in the 5-year-old phantom and 17-100% in the adult phantom. Absorbed organ dose sampled under the shield decreased 67% in the 5-year-old phantom and 16% in the adult phantom. Female gonadal shielding combined with AEC during pelvic radiography increases absorbed dose to organs with greater radiation sensitivity and to unshielded ovaries. Difficulty in proper use of gonadal shields has been well described, and use of female gonadal shielding may be inadvisable given the risks of increasing radiation.

  19. The in vitro protection of human decay accelerating factor and hDAF/heme oxygenase-1 transgenes in porcine aortic endothelial cells against sera of Formosan macaques.

    PubMed

    Tu, C-F; Tai, H-C; Wu, C-P; Ho, L-L; Lin, Y-J; Hwang, C-S; Yang, T-S; Lee, J-M; Tseng, Y-L; Huang, C-C; Weng, C-N; Lee, P-H

    2010-01-01

    To mitigate hyperacute rejection, pigs have been generated with alpha-Gal transferase gene knockout and transgenic expression of human decay accelerating factor (hDAF), MCP, and CD59. Additionally, heme-oxygenase-1 (HO-1) has been suggested to defend endothelial cells. Sera (MS) (0%, 1%, 5%, 10%, and 15%) from Formosan macaques (Macaca cyclopis, MC), an Old World monkey wildly populated in Taiwan, was used to test the protective in vitro, effects of hDAF or hDAF/hHO-1 on porcine aortic endothelial cells (pAEC) derived from hDAF(+), hDAF(+)/hHO-1(+), and hDAF(+)/hHO-1(-) and 1 nontransgenic pAEC. Ten percent human serum (HS) served as a positive control. When MS addition increased to 10% or 15%, all transgenic pAEC exhibited a greater survival than nontransgenic pAEC. Noticeably, 15% MS reduced survived to <10% versus >40% in nontransgenic and transgenic pAEC, respectively. These results revealed that hDAF exerted protective effects against MC complement activation. However, comparing with 10% MS and HS in pAEC of nontransgenic pigs, the survivability was higher in HS, suggesting that complement activation by MS was more toxic than that by HS. Furthermore, hDAF(+)/hHO-1(+) showed no further protection against effects of MS on transgenic pAEC. Copyright 2010 Elsevier Inc. All rights reserved.

  20. Effect of localizer radiograph on radiation dose associated with automatic exposure control: human cadaver and patient study.

    PubMed

    Singh, Sarabjeet; Petrovic, Dean; Jamnik, Ethen; Aran, Shima; Pourjabbar, Sarvenaz; Kave, Maggie L; Bradley, Stephen E; Choy, Garry; Kalra, Mannudeep K

    2014-01-01

    To evaluate the effect of localizing radiograph on computed tomography (CT) radiation dose associated with automatic exposure control with a human cadaver and patient study. Institutional review board approved the study with a waiver of informed consent. Two chest CT image series with fixed tube current and combined longitudinal-angular automatic exposure control (AEC) were acquired in a human cadaver (64-year-old man) after each of the 8 combinations of localizer radiographs (anteroposterior [AP], AP lateral, AP-posteroanterior [PA], lateral AP, lateral PA, PA, PA-AP, and PA lateral). Applied effective milliampere second, volume CT dose index (CTDIvol) and image noise were recorded for all 24-image series. Volume CT dose indexes were also recorded in 20 patients undergoing chest and abdominal CT after PA and PA-lateral radiographs with the use of AEC. Data were analyzed using analysis of variance and linear correlation tests. With AEC, the CTDIvol fluctuates with the number and projection of localizer radiographs (P < 0.0001). Lowest CTDIvol values are seen when 2 orthogonal localizer radiographs are acquired, whereas highest values are seen when single PA or AP-PA projection localizer radiographs are acquired for planning (P < 0.0001). In 20 patients, CT scanning with AEC after acquisition of 2 orthogonal projection localizer radiographs was associated with significant reduction in radiation dose compared to PA projection radiographs alone (P < 0.0001). When scanning with AEC, acquisition of 2 orthogonal localizer radiographs is associated with lower CTDIvol compared to a single localizer radiograph.

  1. Automatic exposure control systems designed to maintain constant image noise: effects on computed tomography dose and noise relative to clinically accepted technique charts.

    PubMed

    Favazza, Christopher P; Yu, Lifeng; Leng, Shuai; Kofler, James M; McCollough, Cynthia H

    2015-01-01

    To compare computed tomography dose and noise arising from use of an automatic exposure control (AEC) system designed to maintain constant image noise as patient size varies with clinically accepted technique charts and AEC systems designed to vary image noise. A model was developed to describe tube current modulation as a function of patient thickness. Relative dose and noise values were calculated as patient width varied for AEC settings designed to yield constant or variable noise levels and were compared to empirically derived values used by our clinical practice. Phantom experiments were performed in which tube current was measured as a function of thickness using a constant-noise-based AEC system and the results were compared with clinical technique charts. For 12-, 20-, 28-, 44-, and 50-cm patient widths, the requirement of constant noise across patient size yielded relative doses of 5%, 14%, 38%, 260%, and 549% and relative noises of 435%, 267%, 163%, 61%, and 42%, respectively, as compared with our clinically used technique chart settings at each respective width. Experimental measurements showed that a constant noise-based AEC system yielded 175% relative noise for a 30-cm phantom and 206% relative dose for a 40-cm phantom compared with our clinical technique chart. Automatic exposure control systems that prescribe constant noise as patient size varies can yield excessive noise in small patients and excessive dose in obese patients compared with clinically accepted technique charts. Use of noise-level technique charts and tube current limits can mitigate these effects.

  2. COAXIAL TUBE COUPLING

    DOEpatents

    Niemoth, H.R.

    1963-02-26

    BS>This patent shows a device for quickly coupling coaxial tubes in metal-to-metal fashion, so as to be suitable for use in a nuclear reactor. A threaded coliar urges a tapered metal extension on the outer coaxial tube into a tapered seat in the device and simultaneously exerts pressure through a coaxial helical spring so that a similar extension on the inner tube seats in a similar seat near the other end. (AEC)

  3. SYSTEM FOR AND METHOD OF DETERMINING RANGE

    DOEpatents

    Horrell, M.W.; Sanders, E.R.

    1963-11-01

    A system and method for indicating a predetermined altitude of an object or aircraft is described. The device utilizes a pulse transmit-receive system wherein pulses of predetermined width are transmitted towards the ground and the reflected pulses received gating only pulses having a predetermined width. (AEC)

  4. Automatic Exposure Control Systems Designed to Maintain Constant Image Noise: Effects on Computed Tomography Dose and Noise Relative to Clinically Accepted Technique Charts

    PubMed Central

    Favazza, Christopher P.; Yu, Lifeng; Leng, Shuai; Kofler, James M.; McCollough, Cynthia H.

    2015-01-01

    Objective To compare computed tomography dose and noise arising from use of an automatic exposure control (AEC) system designed to maintain constant image noise as patient size varies with clinically accepted technique charts and AEC systems designed to vary image noise. Materials and Methods A model was developed to describe tube current modulation as a function of patient thickness. Relative dose and noise values were calculated as patient width varied for AEC settings designed to yield constant or variable noise levels and were compared to empirically derived values used by our clinical practice. Phantom experiments were performed in which tube current was measured as a function of thickness using a constant-noise-based AEC system and the results were compared with clinical technique charts. Results For 12-, 20-, 28-, 44-, and 50-cm patient widths, the requirement of constant noise across patient size yielded relative doses of 5%, 14%, 38%, 260%, and 549% and relative noises of 435%, 267%, 163%, 61%, and 42%, respectively, as compared with our clinically used technique chart settings at each respective width. Experimental measurements showed that a constant noise–based AEC system yielded 175% relative noise for a 30-cm phantom and 206% relative dose for a 40-cm phantom compared with our clinical technique chart. Conclusions Automatic exposure control systems that prescribe constant noise as patient size varies can yield excessive noise in small patients and excessive dose in obese patients compared with clinically accepted technique charts. Use of noise-level technique charts and tube current limits can mitigate these effects. PMID:25938214

  5. [Performance evaluation of CT automatic exposure control on fast dual spiral scan].

    PubMed

    Niwa, Shinji; Hara, Takanori; Kato, Hideki; Wada, Yoichi

    2014-11-01

    The performance of individual computed tomography automatic exposure control (CT-AEC) is very important for radiation dose reduction and image quality equalization in CT examinations. The purpose of this study was to evaluate the performance of CT-AEC in conventional pitch mode (Normal spiral) and fast dual spiral scan (Flash spiral) in a 128-slice dual-source CT scanner. To evaluate the response properties of CT-AEC in the 128-slice DSCT scanner, a chest phantom was placed on the patient table and was fixed at the center of the field of view (FOV). The phantom scan was performed using Normal spiral and Flash spiral scanning. We measured the effective tube current time product (Eff. mAs) of simulated organs in the chest phantom along the longitudinal (z) direction, and the dose dependence (distribution) of in-plane locations for the respective scan modes was also evaluated by using a 100-mm-long pencil-type ionization chamber. The dose length product (DLP) was evaluated using the value displayed on the console after scanning. It was revealed that the response properties of CT-AEC in Normal spiral scanning depend on the respective pitches and Flash spiral scanning is independent of the respective pitches. In-plane radiation dose of Flash spiral was lower than that of Normal spiral. The DLP values showed a difference of approximately 1.7 times at the maximum. The results of our experiments provide information for adjustments for appropriate scanning parameters using CT-AEC in a 128-slice DSCT scanner.

  6. METHOD AND APPARATUS FOR EFFECTING THERMAL BONDS

    DOEpatents

    Monson, H.O.; Jaross, R.A.

    1961-10-17

    A device is described for completing the alkali metal bend between a fael element and its jacket. It consists of a heater and electo1nagic surrounding the fael element so tbat while it is heated a rotating magnetic field will agirate the alkali metal and work out void spaces. (AEC)

  7. EXPERIMENTAL ANIMAL WATERING DEVICE

    DOEpatents

    Finkel, M.P.

    1964-04-01

    A device for watering experimental animals confined in a battery of individual plastic enclosures is described. It consists of a rectangular plastic enclosure having a plurality of fluid-tight compartments, each with a drinking hole near the bottom and a filling hole on the top. The enclosure is immersed in water until filled, its drinking holes sealed with a strip of tape, and it is then placed in the battery. The tape sealing prevents the flow of water from the device, but permits animals to drink by licking the drinking holes. (AEC)

  8. [Protective effect of hydrogen against hyperoxia-induced type II alveolar epithelial cell injury].

    PubMed

    Yao, Lan; Xu, Feng; Luo, Chong; Yu, Pan; Dong, Xinxin; Sun, Xuejun; Liu, Chengjun

    2013-02-01

    To investigate the protective effect of hydrogen against hyperoxia-induced oxidative stress injury in premature rat type II alveolar epithelial cells (AECs). The type II AECs isolated from premature rats were randomly divided into air (21% oxygen) control group, hyperoxia (95% oxygen) control group, air + hydrogen group, and hyperoxia+ hydrogen group. The cells with hydrogen treatment were cultured in the presence of rich hydrogen. After the corresponding exposure for 24 h, the cell morphology was observed microscopically. MTT assay was used to evaluated the cell proliferation ability, and JC-1 fluorescence probe was used to detect the mitochondrial membrane potential (δφ) changes of the type II AECs. The concentration of maleic dialdehyde (MDA) and superoxide dismutase (SOD) activity in the cell supernatant were detected using colorimetric method. No significant differences were found in cell growth or measurements between air control and air + hydrogen groups. Compared with air control group, the cells exposed to hyperoxia showed significantly suppressed proliferation, reduced mitochondrial membrane potential, increased MDA content, and decreased SOD activity. Intervention with hydrogen resulted in significantly increased cell proliferation and SOD activity and lowered MDA content, and restored the mitochondrial membrane potential in the cells with hyperoxia exposure (P<0.05). Hydrogen can significantly reduce hyperoxia-induced oxidative stress injury in premature rat type II AECs, improve the cellular antioxidant capacity, stabilize the mitochondrial membrane potential, and reduce the inhibitory effect of hyperoxia on cell proliferation.

  9. Methods for CT automatic exposure control protocol translation between scanner platforms.

    PubMed

    McKenney, Sarah E; Seibert, J Anthony; Lamba, Ramit; Boone, John M

    2014-03-01

    An imaging facility with a diverse fleet of CT scanners faces considerable challenges when propagating CT protocols with consistent image quality and patient dose across scanner makes and models. Although some protocol parameters can comfortably remain constant among scanners (eg, tube voltage, gantry rotation time), the automatic exposure control (AEC) parameter, which selects the overall mA level during tube current modulation, is difficult to match among scanners, especially from different CT manufacturers. Objective methods for converting tube current modulation protocols among CT scanners were developed. Three CT scanners were investigated, a GE LightSpeed 16 scanner, a GE VCT scanner, and a Siemens Definition AS+ scanner. Translation of the AEC parameters such as noise index and quality reference mAs across CT scanners was specifically investigated. A variable-diameter poly(methyl methacrylate) phantom was imaged on the 3 scanners using a range of AEC parameters for each scanner. The phantom consisted of 5 cylindrical sections with diameters of 13, 16, 20, 25, and 32 cm. The protocol translation scheme was based on matching either the volumetric CT dose index or image noise (in Hounsfield units) between two different CT scanners. A series of analytic fit functions, corresponding to different patient sizes (phantom diameters), were developed from the measured CT data. These functions relate the AEC metric of the reference scanner, the GE LightSpeed 16 in this case, to the AEC metric of a secondary scanner. When translating protocols between different models of CT scanners (from the GE LightSpeed 16 reference scanner to the GE VCT system), the translation functions were linear. However, a power-law function was necessary to convert the AEC functions of the GE LightSpeed 16 reference scanner to the Siemens Definition AS+ secondary scanner, because of differences in the AEC functionality designed by these two companies. Protocol translation on the basis of quantitative metrics (volumetric CT dose index or measured image noise) is feasible. Protocol translation has a dependency on patient size, especially between the GE and Siemens systems. Translation schemes that preserve dose levels may not produce identical image quality. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  10. Tailoring automatic exposure control toward constant detectability in digital mammography.

    PubMed

    Salvagnini, Elena; Bosmans, Hilde; Struelens, Lara; Marshall, Nicholas W

    2015-07-01

    The automatic exposure control (AEC) modes of most full field digital mammography (FFDM) systems are set up to hold pixel value (PV) constant as breast thickness changes. This paper proposes an alternative AEC mode, set up to maintain some minimum detectability level, with the ultimate goal of improving object detectability at larger breast thicknesses. The default "opdose" AEC mode of a Siemens MAMMOMAT Inspiration FFDM system was assessed using poly(methyl methacrylate) (PMMA) of thickness 20, 30, 40, 50, 60, and 70 mm to find the tube voltage and anode/filter combination programmed for each thickness; these beam quality settings were used for the modified AEC mode. Detectability index (d'), in terms of a non-prewhitened model observer with eye filter, was then calculated as a function of tube current-time product (mAs) for each thickness. A modified AEC could then be designed in which detectability never fell below some minimum setting for any thickness in the operating range. In this study, the value was chosen such that the system met the achievable threshold gold thickness (Tt) in the European guidelines for the 0.1 mm diameter disc (i.e., Tt ≤ 1.10 μm gold). The default and modified AEC modes were compared in terms of contrast-detail performance (Tt), calculated detectability (d'), signal-difference-to-noise ratio (SDNR), and mean glandular dose (MGD). The influence of a structured background on object detectability for both AEC modes was examined using a CIRS BR3D phantom. Computer-based CDMAM reading was used for the homogeneous case, while the images with the BR3D background were scored by human observers. The default opdose AEC mode maintained PV constant as PMMA thickness increased, leading to a reduction in SDNR for the homogeneous background 39% and d' 37% in going from 20 to 70 mm; introduction of the structured BR3D plate changed these figures to 22% (SDNR) and 6% (d'), respectively. Threshold gold thickness (0.1 mm diameter disc) for the default AEC mode in the homogeneous background increased by 62% in going from 20 to 70 mm PMMA thickness; in the structured background, the increase was 39%. Implementation of the modified mode entailed an increase in mAs at PMMA thicknesses >40 mm; the modified AEC held threshold gold thickness constant above 40 mm PMMA with a maximum deviation of 5% in the homogeneous background and 3% in structured background. SDNR was also held constant with a maximum deviation of 4% and 2% for the homogeneous and the structured background, respectively. These results were obtained with an increase of MGD between 15% and 73% going from 40 to 70 mm PMMA thickness. This work has proposed and implemented a modified AEC mode, tailored toward constant detectability at larger breast thickness, i.e., above 40 mm PMMA equivalent. The desired improvement in object detectability could be obtained while maintaining MGD within the European guidelines achievable dose limit. (A study designed to verify the performance of the modified mode using more clinically realistic data is currently underway.).

  11. Assessment Environment for Complex Systems Software Guide

    NASA Technical Reports Server (NTRS)

    2013-01-01

    This Software Guide (SG) describes the software developed to test the Assessment Environment for Complex Systems (AECS) by the West Virginia High Technology Consortium (WVHTC) Foundation's Mission Systems Group (MSG) for the National Aeronautics and Space Administration (NASA) Aeronautics Research Mission Directorate (ARMD). This software is referred to as the AECS Test Project throughout the remainder of this document. AECS provides a framework for developing, simulating, testing, and analyzing modern avionics systems within an Integrated Modular Avionics (IMA) architecture. The purpose of the AECS Test Project is twofold. First, it provides a means to test the AECS hardware and system developed by MSG. Second, it provides an example project upon which future AECS research may be based. This Software Guide fully describes building, installing, and executing the AECS Test Project as well as its architecture and design. The design of the AECS hardware is described in the AECS Hardware Guide. Instructions on how to configure, build and use the AECS are described in the User's Guide. Sample AECS software, developed by the WVHTC Foundation, is presented in the AECS Software Guide. The AECS Hardware Guide, AECS User's Guide, and AECS Software Guide are authored by MSG. The requirements set forth for AECS are presented in the Statement of Work for the Assessment Environment for Complex Systems authored by NASA Dryden Flight Research Center (DFRC). The intended audience for this document includes software engineers, hardware engineers, project managers, and quality assurance personnel from WVHTC Foundation (the suppliers of the software), NASA (the customer), and future researchers (users of the software). Readers are assumed to have general knowledge in the field of real-time, embedded computer software development.

  12. [Investigation of radiation dose for lower tube voltage CT using automatic exposure control].

    PubMed

    Takata, Mitsuo; Matsubara, Kousuke; Koshida, Kichirou; Tarohda, Tohru

    2015-04-01

    The purpose of our study was to investigate radiation dose for lower tube voltage CT using automatic exposure control (AEC). An acrylic body phantom was used, and volume CT dose indices (CTDIvol) for tube voltages of 80, 100, 120, and 135 kV were investigated with combination of AEC. Average absorbed dose in the abdomen for 100 and 120 kV were also measured using thermoluminescence dosimeters. In addition, we examined noise characteristics under the same absorbed doses. As a result, the exposure dose was not decreased even when the tube voltage was lowered, and the organ absorbed dose value became approximately 30% high. And the noise was increased under the radiographic condition to be an equal absorbed dose. Therefore, radiation dose increases when AEC is used for lower tube voltage CT under the same standard deviation (SD) setting with 120 kV, and the optimization of SD setting is crucial.

  13. A transgenic reporter under control of an es1 promoter/enhancer marks wound epidermis and apical epithelial cap during tail regeneration in Xenopus laevis tadpole.

    PubMed

    Sato, Kentaro; Umesono, Yoshihiko; Mochii, Makoto

    2018-01-15

    Rapid wound healing and subsequent formation of the apical epithelial cap (AEC) are believed to be required for successful appendage regeneration in amphibians. Despite the significant role of AEC in limb regeneration, its role in tail regeneration and the mechanisms that regulate the wound healing and AEC formation are not well understood. We previously identified Xenopus laevis es1, which is preferentially expressed in wounded regions, including the AEC after tail regeneration. In this study we established and characterized transgenic Xenopus laevis lines harboring the enhanced green fluorescent protein (EGFP) gene under control of an es1 gene regulatory sequence (es1:egfp). The EGFP reporter expression was clearly seen in several regions of the embryo and then declined to an undetectable level in larvae, recapitulating the endogenous es1 expression. After amputation of the tadpole tail, EGFP expression was re-activated at the edge of the stump epidermis and then increased in the wound epidermis (WE) covering the amputation surface. As the stump started to regenerate, the EGFP expression became restricted to the most distal epidermal region, including the AEC. EGFP was preferentially expressed in the basal or deep cells but not in the superficial cells of the WE and AEC. We performed a small-scale pharmacological screening for chemicals that affected the expression of EGFP in the stump epidermis after tail amputation. The EGFP expression was attenuated by treatment with an inhibitor for ERK, TGF-β or reactive oxygen species (ROS) signaling. These treatments also impaired wound closure of the amputation surface, suggesting that the three signaling activities are required for es1 expression in the WE and successful wound healing after tail amputation. These findings showed that es1:egfp Xenopus laevis should be a useful tool to analyze molecular mechanisms regulating wound healing and appendage regeneration. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. CONTINUOUS ANALYZER UTILIZING BOILING POINT DETERMINATION

    DOEpatents

    Pappas, W.S.

    1963-03-19

    A device is designed for continuously determining the boiling point of a mixture of liquids. The device comprises a distillation chamber for boiling a liquid; outlet conduit means for maintaining the liquid contents of said chamber at a constant level; a reflux condenser mounted above said distillation chamber; means for continuously introducing an incoming liquid sample into said reflux condenser and into intimate contact with vapors refluxing within said condenser; and means for measuring the temperature of the liquid flowing through said distillation chamber. (AEC)

  15. Design Engineering in Surgery. How to Design, Test and Market Surgical Devices Made With 3D Printing?

    PubMed

    Rodríguez García, José Ignacio; Sierra Velasco, José Manuel; Villazón Suárez, Marta; Cabrera Pereira, Ana; Sosa, Valentina; Cortizo Rodríguez, José Luis

    2018-04-01

    Industry 4.0 offers new development opportunities for surgeons. Computer-aided design and 3D printing allow for the creation of prototypes and functional end products. Until now, it was difficult for new devices to get to the manufacturing phase. Nowadays, the main limitations are our creativity, available spaces to test our creations and obtaining financing. Copyright © 2018 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. Pulmonary Regnase-1 orchestrates the interplay of epithelium and adaptive immune systems to protect against pneumonia.

    PubMed

    Nakatsuka, Yoshinari; Vandenbon, Alexis; Mino, Takashi; Yoshinaga, Masanori; Uehata, Takuya; Cui, Xiaotong; Sato, Ayuko; Tsujimura, Tohru; Suzuki, Yutaka; Sato, Atsuyasu; Handa, Tomohiro; Chin, Kazuo; Sawa, Teiji; Hirai, Toyohiro; Takeuchi, Osamu

    2018-04-25

    Inhaled pathogens including Pseudomonas aeruginosa initially encounter airway epithelial cells (AECs), which are poised to evoke cell-intrinsic innate defense, affecting second tier of hematopoietic cell-mediated immune reaction. However, it is largely unknown how pulmonary immune responses mediated by a variety of immune cells are coordinated. Here we show that Regnase-1, an endoribonuclease expressed in AECs and immune cells, plays an essential role in coordinating innate responses and adaptive immunity against P. aeruginosa infection. Intratracheal treatment of mice with heat-killed P. aeruginosa resulted in prolonged disappearance of Regnase-1 consistent with sustained expression of Regnase-1 target inflammatory genes, whereas the transcription factor NF-κB was only transiently activated. AEC-specific deletion of Regnase-1 not only augmented innate defenses against P. aeruginosa but also enhanced secretion of Pseudomonas-specific IgA and Th17 accumulation in the lung, culminating in conferring significant resistance against P. aeruginosa re-infection in vivo. Although Regnase-1 directly controls distinct sets of genes in each of AECs and T cells, degradation of Regnase-1 in both cell types is beneficial for maximizing acquired immune responses. Collectively, these results demonstrate that Regnase-1 orchestrates AEC-mediated and immune cell-mediated host defense against pulmonary bacterial infection.

  17. Mitochondrial catalase overexpressed transgenic mice are protected against lung fibrosis in part via preventing alveolar epithelial cell mitochondrial DNA damage.

    PubMed

    Kim, Seok-Jo; Cheresh, Paul; Jablonski, Renea P; Morales-Nebreda, Luisa; Cheng, Yuan; Hogan, Erin; Yeldandi, Anjana; Chi, Monica; Piseaux, Raul; Ridge, Karen; Michael Hart, C; Chandel, Navdeep; Scott Budinger, G R; Kamp, David W

    2016-12-01

    Alveolar epithelial cell (AEC) injury and mitochondrial dysfunction are important in the development of lung fibrosis. Our group has shown that in the asbestos exposed lung, the generation of mitochondrial reactive oxygen species (ROS) in AEC mediate mitochondrial DNA (mtDNA) damage and apoptosis which are necessary for lung fibrosis. These data suggest that mitochondrial-targeted antioxidants should ameliorate asbestos-induced lung. To determine whether transgenic mice that express mitochondrial-targeted catalase (MCAT) have reduced lung fibrosis following exposure to asbestos or bleomycin and, if so, whether this occurs in association with reduced AEC mtDNA damage and apoptosis. Crocidolite asbestos (100µg/50µL), TiO 2 (negative control), bleomycin (0.025 units/50µL), or PBS was instilled intratracheally in 8-10 week-old wild-type (WT - C57Bl/6J) or MCAT mice. The lungs were harvested at 21d. Lung fibrosis was quantified by collagen levels (Sircol) and lung fibrosis scores. AEC apoptosis was assessed by cleaved caspase-3 (CC-3)/Surfactant protein C (SFTPC) immunohistochemistry (IHC) and semi-quantitative analysis. AEC (primary AT2 cells from WT and MCAT mice and MLE-12 cells) mtDNA damage was assessed by a quantitative PCR-based assay, apoptosis was assessed by DNA fragmentation, and ROS production was assessed by a Mito-Sox assay. Compared to WT, crocidolite-exposed MCAT mice exhibit reduced pulmonary fibrosis as measured by lung collagen levels and lung fibrosis score. The protective effects in MCAT mice were accompanied by reduced AEC mtDNA damage and apoptosis. Similar findings were noted following bleomycin exposure. Euk-134, a mitochondrial SOD/catalase mimetic, attenuated MLE-12 cell DNA damage and apoptosis. Finally, compared to WT, asbestos-induced MCAT AT2 cell ROS production was reduced. Our finding that MCAT mice have reduced pulmonary fibrosis, AEC mtDNA damage and apoptosis following exposure to asbestos or bleomycin suggests an important role for AEC mitochondrial H 2 O 2 -induced mtDNA damage in promoting lung fibrosis. We reason that strategies aimed at limiting AEC mtDNA damage arising from excess mitochondrial H 2 O 2 production may be a novel therapeutic target for mitigating pulmonary fibrosis. Published by Elsevier Inc.

  18. Mitochondrial catalase overexpressed transgenic mice are protected against lung fibrosis in part via preventing alveolar epithelial cell mitochondrial DNA damage

    PubMed Central

    Kim, Seok-Jo; Cheresh, Paul; Jablonski, Renea P.; Morales-Nebreda, Luisa; Cheng, Yuan; Hogan, Erin; Yeldandi, Anjana; Chi, Monica; Piseaux, Raul; Ridge, Karen; Hart, C. Michael; Chandel, Navdeep; Budinger, G.R. Scott; Kamp, David W.

    2018-01-01

    Rationale Alveolar epithelial cell (AEC) injury and mitochondrial dysfunction are important in the development of lung fibrosis. Our group has shown that in the asbestos exposed lung, the generation of mitochondrial reactive oxygen species (ROS) in AEC mediate mitochondrial DNA (mtDNA) damage and apoptosis which are necessary for lung fibrosis. These data suggest that mitochondrial-targeted antioxidants should ameliorate asbestos-induced lung. Objective To determine whether transgenic mice that express mitochondrial-targeted catalase (MCAT) have reduced lung fibrosis following exposure to asbestos or bleomycin and, if so, whether this occurs in association with reduced AEC mtDNA damage and apoptosis. Methods Crocidolite asbestos (100 μg/50 μL), TiO2 (negative control), bleomycin (0.025 units/50 μL), or PBS was instilled intratracheally in 8–10 week-old wild-type (WT - C57Bl/6 J) or MCAT mice. The lungs were harvested at 21 d. Lung fibrosis was quantified by collagen levels (Sircol) and lung fibrosis scores. AEC apoptosis was assessed by cleaved caspase-3 (CC-3)/Surfactant protein C (SFTPC) immunohistochemistry (IHC) and semi-quantitative analysis. AEC (primary AT2 cells from WT and MCAT mice and MLE-12 cells) mtDNA damage was assessed by a quantitative PCR-based assay, apoptosis was assessed by DNA fragmentation, and ROS production was assessed by a Mito-Sox assay. Results Compared to WT, crocidolite-exposed MCAT mice exhibit reduced pulmonary fibrosis as measured by lung collagen levels and lung fibrosis score. The protective effects in MCAT mice were accompanied by reduced AEC mtDNA damage and apoptosis. Similar findings were noted following bleomycin exposure. Euk-134, a mitochondrial SOD/catalase mimetic, attenuated MLE-12 cell DNA damage and apoptosis. Finally, compared to WT, asbestos-induced MCAT AT2 cell ROS production was reduced. Conclusions Our finding that MCAT mice have reduced pulmonary fibrosis, AEC mtDNA damage and apoptosis following exposure to asbestos or bleomycin suggests an important role for AEC mitochondrial H2O2-induced mtDNA damage in promoting lung fibrosis. We reason that strategies aimed at limiting AEC mtDNA damage arising from excess mitochondrial H2O2 production may be a novel therapeutic target for mitigating pulmonary fibrosis. PMID:27840320

  19. Alveolar epithelial cells in idiopathic pulmonary fibrosis display upregulation of TRAIL, DR4 and DR5 expression with simultaneous preferential over-expression of pro-apoptotic marker p53.

    PubMed

    Akram, Khondoker M; Lomas, Nicola J; Forsyth, Nicholas R; Spiteri, Monica A

    2014-01-01

    Idiopathic pulmonary fibrosis (IPF) is a progressive, debilitating, and fatal lung disease of unknown aetiology with no current cure. The pathogenesis of IPF remains unclear but repeated alveolar epithelial cell (AEC) injuries and subsequent apoptosis are believed to be among the initiating/ongoing triggers. However, the precise mechanism of apoptotic induction is hitherto elusive. In this study, we investigated expression of a panel of pro-apoptotic and cell cycle regulatory proteins in 21 IPF and 19 control lung tissue samples. We reveal significant upregulation of the apoptosis-inducing ligand TRAIL and its cognate receptors DR4 and DR5 in AEC within active lesions of IPF lungs. This upregulation was accompanied by pro-apoptotic protein p53 overexpression. In contrast, myofibroblasts within the fibroblastic foci of IPF lungs exhibited high TRAIL, DR4 and DR5 expression but negligible p53 expression. Similarly, p53 expression was absent or negligible in IPF and control alveolar macrophages and lymphocytes. No significant differences in TRAIL expression were noted in these cell types between IPF and control lungs. However, DR4 and DR5 upregulation was detected in IPF alveolar macrophages and lymphocytes. The marker of cellular senescence p21(WAF1) was upregulated within affected AEC in IPF lungs. Cell cycle regulatory proteins Cyclin D1 and SOCS3 were significantly enhanced in AEC within the remodelled fibrotic areas of IPF lungs but expression was negligible in myofibroblasts. Taken together these findings suggest that, within the remodelled fibrotic areas of IPF, AEC can display markers associated with proliferation, senescence, and apoptotosis, where TRAIL could drive the apoptotic response. Clear understanding of disease processes and identification of therapeutic targets will direct us to develop effective therapies for IPF.

  20. THERMAL RELAY DEVICE

    DOEpatents

    Murdoch, R.O.; Record, F.A.

    1963-01-29

    This invention relates to a fast-acting spring-loaded electrical switch which can break a 1500-volt circuit in one millisecond without arcing. In particular, a springloaded shorting bar is held in tension by a fusible wire. Passage of an electrical current pulse through the fusible wire breaks the fuse thereby releasing the shorting bar to open one and close another electrical circuit. (AEC)

  1. STABILIZED PINCH MACHINE

    DOEpatents

    Anderson, O.A.

    1962-04-24

    A device for heating and confining a high temperature gas or plasma utilizing the linear pinch effect is described. The pinch discharge produced is the form of an elongated cylinder. The electrical discharge current is returned in parallel along an axial and a concentric conductor whereby the magnetic field of the conductors compresses and stabilizes the pinch discharge against lateral instability. (AEC)

  2. Comparison of Measured and Estimated CT Organ Doses for Modulated and Fixed Tube Current:: A Human Cadaver Study.

    PubMed

    Padole, Atul; Deedar Ali Khawaja, Ranish; Otrakji, Alexi; Zhang, Da; Liu, Bob; Xu, X George; Kalra, Mannudeep K

    2016-05-01

    The aim of this study was to compare the directly measured and the estimated computed tomography (CT) organ doses obtained from commercial radiation dose-tracking (RDT) software for CT performed with modulated tube current or automatic exposure control (AEC) technique and fixed tube current (mAs). With the institutional review board (IRB) approval, the ionization chambers were surgically implanted in a human cadaver (88 years old, male, 68 kg) in six locations such as liver, stomach, colon, left kidney, small intestine, and urinary bladder. The cadaver was scanned with routine abdomen pelvis protocol on a 128-slice, dual-source multidetector computed tomography (MDCT) scanner using both AEC and fixed mAs. The effective and quality reference mAs of 100, 200, and 300 were used for AEC and fixed mAs, respectively. Scanning was repeated three times for each setting, and measured and estimated organ doses (from RDT software) were recorded (N = 3*3*2 = 18). Mean CTDIvol for AEC and fixed mAs were 4, 8, 13 mGy and 7, 14, 21 mGy, respectively. The most estimated organ doses were significantly greater (P < 0.01) than the measured organ doses for both AEC and fixed mAs. At AEC, the mean estimated organ doses (for six organs) were 14.7 mGy compared to mean measured organ doses of 12.3 mGy. Similarly, at fixed mAs, the mean estimated organ doses (for six organs) were 24 mGy compared to measured organ doses of 22.3 mGy. The differences among the measured and estimated organ doses were higher for AEC technique compared to the fixed mAs for most organs (P < 0.01). The most CT organ doses estimated from RDT software are greater compared to directly measured organ doses, particularly when AEC technique is used for CT scanning. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  3. Patency of paediatric endotracheal tubes for airway instrumentation.

    PubMed

    Elfgen, J; Buehler, P K; Thomas, J; Kemper, M; Imach, S; Weiss, M

    2017-01-01

    Airway exchange catheters (AEC) and fiberoptic bronchoscopes (FOB) for tracheal intubation are selected so that there is only a minimal gap between their outer and inner diameter of endotracheal tube (ETT) to minimize the risk of impingement during airway instrumentation. This study aimed to test the ease of passage of FOBs and AECs through paediatric ETT of different sizes and from different manufacturers when using current recommendations for dimensional equipment compatibility taken from text books and manufacturers information. Twelve different brands of cuffed and uncuffed ETT sized ID 2.5 to 5.0 mm were evaluated in an in vitro set-up. Ease of device passage as well as the locations of an impaired passage within the ETT were assessed. Redundant samples were used for same sized ETT and all measurements were triple-checked in randomized order. In total, 51 paired samples of uncuffed as well as cuffed paediatric ETT were tested. There were substantial differences in the ease of ETT passage concordantly for FOBs and AECs among different manufacturers, but also among the product lines from the same manufacturer for a given ID size. Restriction to passage most frequently was found near the endotracheal tube tip or as a gradually increasing resistance along the ETT shaft. Current recommendations for dimensional equipment compatibility AECs and FOBs with ETTs do not appear to be completely accurate for all ETT brands available. We recommend that specific equipment combinations always must be tested carefully together before attempting to use them in a patient. © 2016 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  4. 41 CFR 50-204.34 - AEC licensees-AEC contractors operating AEC plants and facilities-AEC agreement State licensees...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... material, or special nuclear material, as defined in the Atomic Energy Act of 1954, as amended, under a license issued by the Atomic Energy Commission and in accordance with the requirements of 10 CFR part 20... contract with the Atomic Energy Commission for the operation of AEC plants and facilities and in accordance...

  5. 41 CFR 50-204.34 - AEC licensees-AEC contractors operating AEC plants and facilities-AEC agreement State licensees...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... material, or special nuclear material, as defined in the Atomic Energy Act of 1954, as amended, under a license issued by the Atomic Energy Commission and in accordance with the requirements of 10 CFR part 20... contract with the Atomic Energy Commission for the operation of AEC plants and facilities and in accordance...

  6. 41 CFR 50-204.34 - AEC licensees-AEC contractors operating AEC plants and facilities-AEC agreement State licensees...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Alabama, Arkansas, California, Kansas, Kentucky, Florida, Mississippi, New Hampshire, New York, North..., Florida, Mississippi, New Hampshire, New York, North Carolina, Texas, Tennessee, Oregon, Idaho, Arizona...

  7. 41 CFR 50-204.34 - AEC licensees-AEC contractors operating AEC plants and facilities-AEC agreement State licensees...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Alabama, Arkansas, California, Kansas, Kentucky, Florida, Mississippi, New Hampshire, New York, North..., Florida, Mississippi, New Hampshire, New York, North Carolina, Texas, Tennessee, Oregon, Idaho, Arizona...

  8. SU-E-I-48: The Behavior of AEC in Scan Regions Outside the Localizer Radiograph FOV: An In Phantom Study of CT Systems From Four Vendors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Supanich, M; Bevins, N

    Purpose: This review of scanners from 4 major manufacturers examines the clinical impact of performing CT scans that extend into areas of the body that were not acquired in the CT localizer radiograph. Methods: Anthropomorphic chest and abdomen phantoms were positioned together on the tables of CT scanners from 4 different vendors. All of the scanners offered an Automatic Exposure Control (AEC) option with both lateral and axial tube current modulation. A localizer radiograph was taken covering the entire extent of both phantoms and then the scanner's Chest-Abdomen-Pelvis (CAP) study was performed with the clinical AEC settings employed and themore » scan and reconstruction range extending from the superior portion of the chest phantom through the inferior portion of the abdomen phantom. A new study was then initiated with a localizer radiograph extending the length of the chest phantom (not covering the abdomen phantom). The same CAP protocol and AEC settings were then used to scan and reconstruct the entire length of both phantoms. Scan parameters at specific locations in the abdomen phantom from both studies were investigated using the information contained in the DICOM metadata of the reconstructed images. Results: The AEC systems on all scanners utilized different tube current settings in the abdomen phantom for the scan completed without the full localizer radiograph. The AEC system behavior was also scanner dependent with the default manual tube current, the maximum tube current and the tube current at the last known position observed as outcomes. Conclusion: The behavior of the AEC systems of CT scanners in regions not covered by the localizer radiograph is vendor dependent. To ensure optimal image quality and radiation exposure it is important to include the entire planned scan region in the localizer radiograph.« less

  9. Anti-inflammatory and anti-apoptotic effects of Crataegus oxyacantha on isoproterenol-induced myocardial damage.

    PubMed

    Vijayan, Navin Alukkathara; Thiruchenduran, Mohana; Devaraj, Sivasitamparam Niranjali

    2012-08-01

    This study was designed to evaluate the anti-inflammatory and anti-apoptotic effects of the alcoholic extract of the berries of Crataegus oxyacantha (AEC), a medicinal herb, on isoproterenol-induced myocardial infarction (MI) in a rat model. Three groups of Wistar albino rats, each comprising six animals, were selected for this study. Group I rats served as control. Group II rats were given isoproterenol (85 mg/kg body weight) subcutaneously on 59th and 60th days. Group III rats were given AEC (0.5 ml/100 g body weight/day), orally on a daily basis for 60 days, and isoproterenol (85 mg/kg body weight, subcutaneously) was given on 59th and 60th days. On the 61st day, the animals were sacrificed, and marker enzymes like lactate dehydrogenase (LDH) and creatine kinase (CK) were estimated in serum. In the heart tissue sample, antioxidant status, lipid peroxidation and anti-inflammatory properties of AEC were determined. Isoproterenol significantly increased the release of LDH, CK in serum, decreased the antioxidant status in the heart along with an increase in lipid peroxidation. Nitritive stress and apoptosis were seen in isoproterenol-induced rat heart. Pre-treatment with the AEC for 60 days had a significant effect on all the above factors and maintained near normal status. The study confirms the protective effect of AEC against isoproterenol-induced inflammation and apoptosis-associated MI in rats.

  10. Modeling pulmonary fibrosis by abnormal expression of telomerase/apoptosis/collagen V in experimental usual interstitial pneumonia

    PubMed Central

    Parra, E.R.; Pincelli, M.S.; Teodoro, W.R.; Velosa, A.P.P.; Martins, V.; Rangel, M.P.; Barbas-Filho, J.V.; Capelozzi, V.L.

    2014-01-01

    Limitations on tissue proliferation capacity determined by telomerase/apoptosis balance have been implicated in pathogenesis of idiopathic pulmonary fibrosis. In addition, collagen V shows promise as an inductor of apoptosis. We evaluated the quantitative relationship between the telomerase/apoptosis index, collagen V synthesis, and epithelial/fibroblast replication in mice exposed to butylated hydroxytoluene (BHT) at high oxygen concentration. Two groups of mice were analyzed: 20 mice received BHT, and 10 control mice received corn oil. Telomerase expression, apoptosis, collagen I, III, and V fibers, and hydroxyproline were evaluated by immunohistochemistry, in situ detection of apoptosis, electron microscopy, immunofluorescence, and histomorphometry. Electron microscopy confirmed the presence of increased alveolar epithelial cells type 1 (AEC1) in apoptosis. Immunostaining showed increased nuclear expression of telomerase in AEC type 2 (AEC2) between normal and chronic scarring areas of usual interstitial pneumonia (UIP). Control lungs and normal areas from UIP lungs showed weak green birefringence of type I and III collagens in the alveolar wall and type V collagen in the basement membrane of alveolar capillaries. The increase in collagen V was greater than collagens I and III in scarring areas of UIP. A significant direct association was found between collagen V and AEC2 apoptosis. We concluded that telomerase, collagen V fiber density, and apoptosis evaluation in experimental UIP offers the potential to control reepithelization of alveolar septa and fibroblast proliferation. Strategies aimed at preventing high rates of collagen V synthesis, or local responses to high rates of cell apoptosis, may have a significant impact in pulmonary fibrosis. PMID:24919172

  11. TRAVELING WAVE PYROTRON

    DOEpatents

    Post, R.F.

    1963-06-11

    The invention relates to a pyrotron, i.e., magnetic mirror device, designed for continuous operation in producing a high-temperature fusion reaction plasma and for directly converting the plasma energy into electrical power. The device utilizes a system in which an axially symmetric magnetic field is produced and transports plasma through a first zone of progressively rising field intensity, a second reaction zone of slowly increasing intensity, and thenceforth through a third zone of progressively decreasing intensity wherein the plasma expands against the magnetic field thereby producing electrical current in magnetic field generating solenoids associated with said third zone. (AEC)

  12. Non-antibiotic selection systems for soybean somatic embryos: the lysine analog aminoethyl-cysteine as a selection agent

    PubMed Central

    2009-01-01

    Background In soybean somatic embryo transformation, the standard selection agent currently used is hygromycin. It may be preferable to avoid use of antibiotic resistance genes in foods. The objective of these experiments was to develop a selection system for producing transgenic soybean somatic embryos without the use of antibiotics such as hygromycin. Results When tested against different alternate selection agents our studies show that 0.16 μg/mL glufosinate, 40 mg/L isopropylamine-glyphosate, 0.5 mg/mL (S-(2 aminoethyl)-L-cysteine) (AEC) and the acetolactate synthase (ALS) inhibitors Exceed® and Synchrony® both at 150 μg/mL inhibited soybean somatic embryo growth. Even at the concentration of 2 mg/mL, lysine+threonine (LT) were poor selection agents. The use of AEC may be preferable since it is a natural compound. Unlike the plant enzyme, dihydrodipicolinate synthase (DHPS) from E. coli is not feed-back inhibited by physiological concentrations of lysine. The dapA gene which codes for E. coli DHPS was expressed in soybean somatic embryos under the control of the CaMV 35S promoter. Following introduction of the construct into embryogenic tissue of soybean, transgenic events were recovered by incubating the tissue in liquid medium containing AEC at a concentration of 5 mM. Only transgenic soybeans were able to grow at this concentration of AEC; no escapes were observed. Conclusion Genetically engineered soybeans expressing a lysine insensitive DHPS gene can be selected with the non-antibiotic selection agent AEC. We also report here the inhibitory effects of glufosinate, (isopropylamine-glyphosate) (Roundup®), AEC and the ALS inhibitors Exceed® and Synchrony® against different tissues of soybean PMID:19922622

  13. Development of 2.8 V Ketjen black supercapacitors with high rate capabilities for AC line filtering

    NASA Astrophysics Data System (ADS)

    Yoo, Yongju; Park, Jinwoo; Kim, Min-Seop; Kim, Woong

    2017-08-01

    Supercapacitors are generally more compact than conventional bulky aluminum electrolytic capacitors (AECs). Replacement of AECs with supercapacitors can lead to miniaturization of electronic devices. However, even state-of-the-art supercapacitors developed in laboratories are superior to or competitive with AECs only in low voltage applications (<∼40 V). In order to improve the voltage limits of current supercapacitors, we have incorporated Ketjen black (KB) as an electrode material. Utilizing the open pore structure and the graphitic nature of KB, we demonstrate that the voltage limit can be extended to 53 V. The KB supercapacitor exhibits excellent areal capacitance, cell voltage, and phase angle values of ∼574 μF cm-2, 2.8 V, and ∼-80°, respectively. In addition, we demonstrate that an AC line filtering circuit with three supercapacitors connected in series can extend the application voltage without significant sacrifice in rate capability (ϕ ∼ -77° at 120 Hz). On the other hand, KBs are much less expensive than carbon materials previously demonstrated for AC line filtering and hence are very attractive for practical applications. We believe that this demonstration of high-performance supercapacitors made from low-cost carbon materials is both scientifically interesting and important for practical applications.

  14. REACTOR CONTROL ROD OPERATING SYSTEM

    DOEpatents

    Miller, G.

    1961-12-12

    A nuclear reactor control rod mechanism is designed which mechanically moves the control rods into and out of the core under normal conditions but rapidly forces the control rods into the core by catapultic action in the event of an emergency. (AEC)

  15. SIMULATING LOCAL DENSE AREAS USING PMMA TO ASSESS AUTOMATIC EXPOSURE CONTROL IN DIGITAL MAMMOGRAPHY.

    PubMed

    Bouwman, R W; Binst, J; Dance, D R; Young, K C; Broeders, M J M; den Heeten, G J; Veldkamp, W J H; Bosmans, H; van Engen, R E

    2016-06-01

    Current digital mammography (DM) X-ray systems are equipped with advanced automatic exposure control (AEC) systems, which determine the exposure factors depending on breast composition. In the supplement of the European guidelines for quality assurance in breast cancer screening and diagnosis, a phantom-based test is included to evaluate the AEC response to local dense areas in terms of signal-to-noise ratio (SNR). This study evaluates the proposed test in terms of SNR and dose for four DM systems. The glandular fraction represented by the local dense area was assessed by analytic calculations. It was found that the proposed test simulates adipose to fully glandular breast compositions in attenuation. The doses associated with the phantoms were found to match well with the patient dose distribution. In conclusion, after some small adaptations, the test is valuable for the assessment of the AEC performance in terms of both SNR and dose. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salvagnini, Elena, E-mail: elena.salvagnini@uzleuven.be; Bosmans, Hilde; Struelens, Lara

    Purpose: The automatic exposure control (AEC) modes of most full field digital mammography (FFDM) systems are set up to hold pixel value (PV) constant as breast thickness changes. This paper proposes an alternative AEC mode, set up to maintain some minimum detectability level, with the ultimate goal of improving object detectability at larger breast thicknesses. Methods: The default “OPDOSE” AEC mode of a Siemens MAMMOMAT Inspiration FFDM system was assessed using poly(methyl methacrylate) (PMMA) of thickness 20, 30, 40, 50, 60, and 70 mm to find the tube voltage and anode/filter combination programmed for each thickness; these beam quality settingsmore » were used for the modified AEC mode. Detectability index (d′), in terms of a non-prewhitened model observer with eye filter, was then calculated as a function of tube current-time product (mAs) for each thickness. A modified AEC could then be designed in which detectability never fell below some minimum setting for any thickness in the operating range. In this study, the value was chosen such that the system met the achievable threshold gold thickness (T{sub t}) in the European guidelines for the 0.1 mm diameter disc (i.e., T{sub t} ≤ 1.10 μm gold). The default and modified AEC modes were compared in terms of contrast-detail performance (T{sub t}), calculated detectability (d′), signal-difference-to-noise ratio (SDNR), and mean glandular dose (MGD). The influence of a structured background on object detectability for both AEC modes was examined using a CIRS BR3D phantom. Computer-based CDMAM reading was used for the homogeneous case, while the images with the BR3D background were scored by human observers. Results: The default OPDOSE AEC mode maintained PV constant as PMMA thickness increased, leading to a reduction in SDNR for the homogeneous background 39% and d′ 37% in going from 20 to 70 mm; introduction of the structured BR3D plate changed these figures to 22% (SDNR) and 6% (d′), respectively. Threshold gold thickness (0.1 mm diameter disc) for the default AEC mode in the homogeneous background increased by 62% in going from 20 to 70 mm PMMA thickness; in the structured background, the increase was 39%. Implementation of the modified mode entailed an increase in mAs at PMMA thicknesses >40 mm; the modified AEC held threshold gold thickness constant above 40 mm PMMA with a maximum deviation of 5% in the homogeneous background and 3% in structured background. SDNR was also held constant with a maximum deviation of 4% and 2% for the homogeneous and the structured background, respectively. These results were obtained with an increase of MGD between 15% and 73% going from 40 to 70 mm PMMA thickness. Conclusions: This work has proposed and implemented a modified AEC mode, tailored toward constant detectability at larger breast thickness, i.e., above 40 mm PMMA equivalent. The desired improvement in object detectability could be obtained while maintaining MGD within the European guidelines achievable dose limit. (A study designed to verify the performance of the modified mode using more clinically realistic data is currently underway.)« less

  17. CONCENTRIC TUBE FUEL ELEMENT SPRING ALIGNMENT SPACER DEVICE

    DOEpatents

    Weems, S.J.

    1963-09-24

    A rib construction for a nuclear-fuel element is described, in which one of three peripherally spaced ribs adjacent to each end of the fuel element is mounted on a radially yielding spring that embraces the fuel element. This spring enables the fuel element to have a good fit with a coolant tube and yet to be easily inserted in and withdrawn from the tube. (AEC)

  18. A routine quality assurance test for CT automatic exposure control systems.

    PubMed

    Iball, Gareth R; Moore, Alexis C; Crawford, Elizabeth J

    2016-07-08

    The study purpose was to develop and validate a quality assurance test for CT automatic exposure control (AEC) systems based on a set of nested polymethylmethacrylate CTDI phantoms. The test phantom was created by offsetting the 16 cm head phantom within the 32 cm body annulus, thus creating a three part phantom. This was scanned at all acceptance, routine, and some nonroutine quality assurance visits over a period of 45 months, resulting in 115 separate AEC tests on scanners from four manufacturers. For each scan the longitudinal mA modulation pattern was generated and measurements of image noise were made in two annular regions of interest. The scanner displayed CTDIvol and DLP were also recorded. The impact of a range of AEC configurations on dose and image quality were assessed at acceptance testing. For systems that were tested more than once, the percentage of CTDIvol values exceeding 5%, 10%, and 15% deviation from baseline was 23.4%, 12.6%, and 8.1% respectively. Similarly, for the image noise data, deviations greater than 2%, 5%, and 10% from baseline were 26.5%, 5.9%, and 2%, respectively. The majority of CTDIvol and noise deviations greater than 15% and 5%, respectively, could be explained by incorrect phantom setup or protocol selection. Barring these results, CTDIvol deviations of greater than 15% from baseline were found in 0.9% of tests and noise deviations greater than 5% from baseline were found in 1% of tests. The phantom was shown to be sensitive to changes in AEC setup, including the use of 3D, longitudinal or rotational tube current modulation. This test methodology allows for continuing performance assessment of CT AEC systems, and we recommend that this test should become part of routine CT quality assurance programs. Tolerances of ± 15% for CTDIvol and ± 5% for image noise relative to baseline values should be used. © 2016 The Authors

  19. Conditioned medium derived from rat amniotic epithelial cells confers protection against inflammation, cancer, and senescence.

    PubMed

    Di Germanio, Clara; Bernier, Michel; Petr, Michael; Mattioli, Mauro; Barboni, Barbara; de Cabo, Rafael

    2016-06-28

    Amniotic epithelial cells (AECs) are a class of fetal stem cells that derives from the epiblast and resides in the amnion until birth. AECs are suitable candidates for regenerative medicine because of the ease of collection, their low immunogenicity and inability to form tumors after transplantation. Even though human AECs have been widely investigated, the fact remains that very little is known about AECs isolated from rat, one of the most common animal models in medical testing. In this study, we showed that rat AECs retained stemness properties and plasticity, expressed the pluripotency markers Sox2, Nanog, and Oct4 and were able to differentiate toward the osteogenic lineage. The addition of conditioned medium collected from rat AECs to lipopolysaccharide-activated macrophages elicited anti-inflammatory properties through a decrease of Tnfa expression and slowed tumor cell proliferation in vitro and in vivo. The senescence-associated secretory phenotype was also significantly lower upon incubation of senescent human IMR-90 fibroblast cells with conditioned medium from rat AECs. These results confirm the potential of AECs in the modulation of inflammatory mechanisms and open new therapeutic possibilities for regenerative medicine and anti-aging therapies as well.

  20. Design and implementation of a hybrid sub-band acoustic echo canceller (AEC)

    NASA Astrophysics Data System (ADS)

    Bai, Mingsian R.; Yang, Cheng-Ken; Hur, Ker-Nan

    2009-04-01

    An efficient method is presented for implementing an acoustic echo canceller (AEC) that makes use of hybrid sub-band approach. The hybrid system is comprised of a fixed processor and an adaptive filter in each sub-band. The AEC aims at reducing the echo resulting from the acoustic feedback in loudspeaker-enclosure-microphone (LEM) systems such as teleconferencing and hands-free systems. In order to cancel the acoustical echo efficiently, various processing architectures including fixed filters, hybrid processors, and sub-band structure are investigated. A double-talk detector is incorporated into the proposed AEC to prevent the adaptive filter from diverging in double-talk situations. A de-correlation filter is also used alongside sub-band processing in order to enhance the performance and efficiency of AEC. All algorithms are implemented and verified on the platform of a fixed-point digital signal processor (DSP). The AECs are evaluated in terms of cancellation performance and computation complexity. In addition, listening tests are conducted to assess the subjective performance of the AECs. From the results, the proposed hybrid sub-band AEC was found to be the most effective among all methods in terms of echo reduction and timbral quality.

  1. COMPACT CASCADE IMPACTS

    DOEpatents

    Lippmann, M.

    1964-04-01

    A cascade particle impactor capable of collecting particles and distributing them according to size is described. In addition the device is capable of collecting on a pair of slides a series of different samples so that less time is required for the changing of slides. Other features of the device are its compactness and its ruggedness making it useful under field conditions. Essentially the unit consists of a main body with a series of transverse jets discharging on a pair of parallel, spaced glass plates. The plates are capable of being moved incremental in steps to obtain the multiple samples. (AEC)

  2. Assessment of automatic exposure control performance in digital mammography using a no-reference anisotropic quality index

    NASA Astrophysics Data System (ADS)

    Barufaldi, Bruno; Borges, Lucas R.; Bakic, Predrag R.; Vieira, Marcelo A. C.; Schiabel, Homero; Maidment, Andrew D. A.

    2017-03-01

    Automatic exposure control (AEC) is used in mammography to obtain acceptable radiation dose and adequate image quality regardless of breast thickness and composition. Although there are physics methods for assessing the AEC, it is not clear whether mammography systems operate with optimal dose and image quality in clinical practice. In this work, we propose the use of a normalized anisotropic quality index (NAQI), validated in previous studies, to evaluate the quality of mammograms acquired using AEC. The authors used a clinical dataset that consists of 561 patients and 1,046 mammograms (craniocaudal breast views). The results show that image quality is often maintained, even at various radiation levels (mean NAQI = 0.14 +/- 0.02). However, a more careful analysis of NAQI reveals that the average image quality decreases as breast thickness increases. The NAQI is reduced by 32% on average, when the breast thickness increases from 31 to 71 mm. NAQI also decreases with lower breast density. The variation in breast parenchyma alone cannot fully account for the decrease of NAQI with thickness. Examination of images shows that images of large, fatty breasts are often inadequately processed. This work shows that NAQI can be applied in clinical mammograms to assess mammographic image quality, and highlights the limitations of the automatic exposure control for some images.

  3. Enhanced rifampicin delivery to alveolar macrophages by solid lipid nanoparticles

    NASA Astrophysics Data System (ADS)

    Chuan, Junlan; Li, Yanzhen; Yang, Likai; Sun, Xun; Zhang, Qiang; Gong, Tao; Zhang, Zhirong

    2013-05-01

    The present study aimed at developing a drug delivery system targeting the densest site of tuberculosis infection, the alveolar macrophages (AMs). Rifampicin (RFP)-loaded solid lipid nanoparticles (RFP-SLNs) with an average size of 829.6 ± 16.1 nm were prepared by a modified lipid film hydration method. The cytotoxicity of RFP-SLNs to AMs and alveolar epithelial type II cells (AECs) was examined using MTT assays. The viability of AMs and AECs was above 80 % after treatment with RFP-SLNs, which showed low toxicity to both AMs and AECs. Confocal Laser Scanning Microscopy was employed to observe the interaction between RFP-SLNs and both AMs and AECs. After incubating the cells with RFP-SLNs for 2 h, the fluorescent intensity in AMs was more and remained longer (from 0.5 to 12 h) when compared with that in AECs (from 0.5 to 8 h). In vitro uptake characteristics of RFP-SLNs in AMs and AECs were also investigated by detection of intracellular RFP by High performance liquid chromatography. Results showed that RFP-SLNs delivered markedly higher RFP into AMs (691.7 ng/mg in cultured AMs, 662.6 ng/mg in primary AMs) than that into AECs (319.2 ng/mg in cultured AECs, 287.2 ng/mg in primary AECs). Subsequently, in vivo delivery efficiency and the selectivity of RFP-SLNs were further verified in Sprague-Dawley rats. Under pulmonary administration of RFP-SLNs, the amount of RFP in AMs was significantly higher than that in AECs at each time point. Our results demonstrated that solid lipid nanoparticles are a promising strategy for the delivery of rifampicin to alveolar macrophages selectively.

  4. Expression pattern of salt tolerance-related genes in Aegilops cylindrica.

    PubMed

    Arabbeigi, Mahbube; Arzani, Ahmad; Majidi, Mohammad Mahdi; Sayed-Tabatabaei, Badraldin Ebrahim; Saha, Prasenjit

    2018-02-01

    Aegilops cylindrica , a salt-tolerant gene pool of wheat, is a useful plant model for understanding mechanism of salt tolerance. A salt-tolerant USL26 and a salt-sensitive K44 genotypes of A. cylindrica , originating from Uremia Salt Lake shores in Northwest Iran and a non-saline Kurdestan province in West Iran, respectively, were identified based on screening evaluation and used for this work. The objective of the current study was to investigate the expression patterns of four genes related to ion homeostasis in this species. Under treatment of 400 mM NaCl, USL26 showed significantly higher root and shoot dry matter levels and K + concentrations, together with lower Na + concentrations than K44 genotype. A. cylindrica HKT1;5 ( AecHKT1;5 ), SOS1 ( AecSOS1 ), NHX1 ( AecNHX1 ) and VP1 ( AecVP1 ) were partially sequenced to design each gene specific primer. Quantitative real-time PCR showed a differential expression pattern of these genes between the two genotypes and between the root and shoot tissues. Expressions of AecHKT1;5 and AecSOS1 was greater in the roots than in the shoots of USL26 while AecNHX1 and AecVP1 were equally expressed in both tissues of USL26 and K44. The higher transcripts of AecHKT1;5 in the roots versus the shoots could explain both the lower Na + in the shoots and the much lower Na + and higher K + concentrations in the roots/shoots of USL26 compared to K44. Therefore, the involvement of AecHKT1;5 in shoot-to-root handover of Na + in possible combination with the exclusion of excessive Na + from the root in the salt-tolerant genotype are suggested.

  5. SU-E-I-24: Method for CT Automatic Exposure Control Verification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gracia, M; Olasolo, J; Martin, M

    Purpose: Design of a phantom and a simple method for the automatic exposure control (AEC) verification in CT. This verification is included in the computed tomography (CT) Spanish Quality Assurance Protocol. Methods: The phantom design is made from the head and the body phantom used for the CTDI measurement and PMMA plates (35×35 cm2) of 10 cm thickness. Thereby, three different thicknesses along the longitudinal axis are obtained which permit to evaluate the longitudinal AEC performance. Otherwise, the existent asymmetry in the PMMA layers helps to assess angular and 3D AEC operation.Recent acquisition in our hospital (August 2014) of Nomexmore » electrometer (PTW), together with the 10 cm pencil ionization chamber, led to register dose rate as a function of time. Measurements with this chamber fixed at 0° and 90° on the gantry where made on five multidetector-CTs from principal manufacturers. Results: Individual analysis of measurements shows dose rate variation as a function of phantom thickness. The comparative analysis shows that dose rate is kept constant in the head and neck phantom while the PMMA phantom exhibits an abrupt variation between both results, being greater results at 90° as the thickness of the phantom is 3.5 times larger than in the perpendicular direction. Conclusion: Proposed method is simple, quick and reproducible. Results obtained let a qualitative evaluation of the AEC and they are consistent with the expected behavior. A line of future development is to quantitatively study the intensity modulation and parameters of image quality, and a possible comparative study between different manufacturers.« less

  6. Can access to spirometry in asthma education centres influence the referral rate by primary physicians for education?

    PubMed

    Labrecque, M; Lavallée, M; Beauchesne, M F; Cartier, A; Boulet, L P

    2006-01-01

    Asthma remains uncontrolled in a large number of asthmatic patients. Recent surveys have shown that a minority of asthmatic patients are referred to asthma educators. The objective of the present study was to assess the influence of increased access to spirometry in asthma education centres (AECs) on the rate of patient referrals to these centres by general practitioners. A one-year, prospective, randomized, multicentric, parallel group study was conducted over two consecutive periods of six months each, with added spirometry being offered in the second six-month period to the experimental group. Ten AECs were enrolled in the project. An advertisement describing the AECs' services was sent by mail to a total of 303 general practitioners at the start of each period, inviting them to refer their patients. Measures of the frequency of medical referrals to the AECs were assessed for each period. The group of AECs randomly selected for spirometry in the second six-month period received 48 medical referrals during the first period and 32 during the second one, following proposed spirometry. AECs that had not offered spirometry received five referrals during the first period and seven during the second period. One AEC withdrew a few weeks after the study began and others encountered administrative problems, reducing their ability to provide interventions. Referral to AECs is not yet integrated into the primary care of asthma and offering more rapid access to spirometry in the AECs does not seem to be a significant incentive for such referrals.

  7. Exosomes derived from human amniotic epithelial cells accelerate wound healing and inhibit scar formation.

    PubMed

    Zhao, Bin; Zhang, Yijie; Han, Shichao; Zhang, Wei; Zhou, Qin; Guan, Hao; Liu, Jiaqi; Shi, Jihong; Su, Linlin; Hu, Dahai

    2017-04-01

    Wound healing is a highly orchestrated physiological process consisting of a complex events, and scarless wound healing is highly desired for the development and application in clinical medicine. Recently, we have demonstrated that human amniotic epithelial cells (hAECs) promoted wound healing and inhibited scar formation through a paracrine mechanism. However, exosomes (Exo) are one of the most important paracrine factors. Whether exosomes derived from human amniotic epithelial cells (hAECs-Exo) have positive effects on scarless wound healing have not been reported yet. In this study, we examined the role of hAECs-Exo on wound healing in a rat model. We found that hAECs, which exhibit characteristics of both embryonic and mesenchymal stem cells, have the potential to differentiate into all three germ layers. hAECs-Exo ranged from 50 to 150 nm in diameter, and positive for exosomal markers CD9, CD63, CD81, Alix, TSG101 and HLA-G. Internalization of hAECs-Exo promoted the migration and proliferation of fibroblasts. Moreover, the deposition of extracellular matrix (ECM) were partly abolished by the treatment of high concentration of hAECs-Exo (100 μg/mL), which may be through stimulating the expression of matrix metalloproteinase-1 (MMP-1). In vivo animal experiments showed that hAECs-Exo improved the skin wound healing with well-organized collagen fibers. Taken together, These findings represent that hAECs-Exo can be used as a novel hope in cell-free therapy for scarless wound healing.

  8. FAST NEUTRON DOSIMETER FOR HIGH TEMPERATURE OPERATION BY MEASUREMENT OF THE AMOUNT OF CESIUM 137 FORMED FROM A THORIUM WIRE

    DOEpatents

    McCune, D.A.

    1964-03-17

    A method and device for measurement of integrated fast neutron flux in the presence of a large thermal neutron field are described. The device comprises a thorium wire surrounded by a thermal neutron attenuator that is, in turn, enclosed by heat-resistant material. The method consists of irradiating the device in a neutron field whereby neutrons with energies in excess of 1.1 Mev cause fast fissions in the thorium, then removing the thorium wire, separating the cesium-137 fission product by chemical means from the thorium, and finally counting the radioactivity of the cesium to determine the number of fissions which have occurred so that the integrated fast flux may be obtained. (AEC)

  9. ION MAGNETRON

    DOEpatents

    Gow, J.D.; Layman, R.W.

    1962-10-31

    A magnetohydrodynamic device or plasma generator of the ion magnetron class is described wherein a long central electrode is disposed along the axis of an evacuated cylinder. A radial electric field and an axial magnetic field are provided between the cylsnder and the electrode, forming a plasma trapping and heating region. For maximum effectiveness, neutral particles from the cylinder wall must be prevented from entering such region This is effected by forming a cylindrical sheath of electrons near the cylinder wall for ionizing undesired neutral particles, which are then trapped and removed by the magnetic field. An annular filament at one end of the device provides the electrons, which follow the axial magnetic field to a reflecting electrode at the opposite end of the device. (AEC)

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsalafoutas, Ioannis A.; Varsamidis, Athanasios; Thalassinou, Stella

    Purpose: To investigate the utility of the nested polymethylacrylate (PMMA) phantom (which is available in many CT facilities for CTDI measurements), as a tool for the presentation and comparison of the ways that two different CT automatic exposure control (AEC) systems respond to a phantom when various scan parameters and AEC protocols are modified.Methods: By offsetting the two phantom's components (the head phantom and the body ring) half-way along their longitudinal axis, a phantom with three sections of different x-ray attenuation was created. Scan projection radiographs (SPRs) and helical scans of the three-section phantom were performed on a Toshiba Aquilionmore » 64 and a Philips Brilliance 64 CT scanners, with different scan parameter selections [scan direction, pitch factor, slice thickness, and reconstruction interval (ST/RI), AEC protocol, and tube potential used for the SPRs]. The dose length product (DLP) values of each scan were recorded and the tube current (mA) values of the reconstructed CT images were plotted against the respective Z-axis positions on the phantom. Furthermore, measurements of the noise levels at the center of each phantom section were performed to assess the impact of mA modulation on image quality.Results: The mA modulation patterns of the two CT scanners were very dissimilar. The mA variations were more pronounced for Aquilion 64, where changes in any of the aforementioned scan parameters affected both the mA modulations curves and DLP values. However, the noise levels were affected only by changes in pitch, ST/RI, and AEC protocol selections. For Brilliance 64, changes in pitch affected the mA modulation curves but not the DLP values, whereas only AEC protocol and SPR tube potential selection variations affected both the mA modulation curves and DLP values. The noise levels increased for smaller ST/RI, larger weight category AEC protocol, and larger SPR tube potential selection.Conclusions: The nested PMMA dosimetry phantom can be effectively utilized for the comprehension of CT AEC systems performance and the way that different scan conditions affect the mA modulation patterns, DLP values, and image noise. However, in depth analysis of the reasons why these two systems exhibited such different behaviors in response to the same phantom requires further investigation which is beyond the scope of this study.« less

  11. Research Needs: Prime-Power for High Energy Space Systems.

    DTIC Science & Technology

    1982-06-01

    nuclear sources included both developments from earlier NASA/AEC efforts, such as the present SP-100 program , and also advanced concepts in the form of...and, in some cases, set aside). major programs of applied-research and exploratory- development exist at AFWAL and at NASA labora- tories. The results...decades. In such a research program , the particular I problems of a specific device presently under development are less important than the creation of

  12. METHOD AND APPARATUS FOR EXAMINING FUEL ELEMENTS FOR LEAKAGE

    DOEpatents

    Smith, R.R.; Echo, M.W.; Doe, C.B.

    1963-12-31

    A process and a device for the continuous monitoring of fuel elements while in use in a liquid-metal-cooled, argonblanketed nuclear reactor are presented. A fraction of the argon gas is withdrawn, contacted with a negative electrical charge for attraction of any alkali metal formed from argon by neutron reaction, and recycled into the reactor. The electrical charge is introduced into water, and the water is examined for radioactive alkali metals. (AEC)

  13. ACCELERATION RESPONSIVE SWITCH

    DOEpatents

    Chabrek, A.F.; Maxwell, R.L.

    1963-07-01

    An acceleration-responsive device with dual channel capabilities whereby a first circuit is actuated upon attainment of a predetermined maximum acceleration level and when the acceleration drops to a predetermined minimum acceleriltion level another circuit is actuated is described. A fluid-damped sensing mass slidably mounted in a relatively frictionless manner on a shaft through the intermediation of a ball bushing and biased by an adjustable compression spring provides inertially operated means for actuating the circuits. (AEC)

  14. AEC to Referee, Not Promote, Industry.

    PubMed

    1971-10-29

    A major turnabout in the attitude of the Atomic Energy Commission toward the nuclear power industry was signaled last week by the ntew AEC chairman James R. Schlesinger. With patrician froideur, Schlesinger informed a mass gathering of the nuclear power industry at Bal Harbour, Florida, that from henceforth the AEC woLuld act as the referee of nuclear power, not its promoter. Saying he would dispense with the "anecdotes and clumsy jests" customary on such occasions, Schlesinger served notice on the nuclear banqueters that their cozy relationship with the AEC was at an end. The industry should not expect the AEC to fight its battles: it should take its own case to the public-as the Sierra Club does. Nor did the AEC intend to bend the rules in industry's favor. "We have had a fair amount of advice on how to evade the clear mandate of the federal courts. It is advice we did not think proper to accept," Schlesinger said. Even on matters of engineering quality, the diners were told they knew full well they had "reason to blush." Roused out of any postprandial euphoria by this glacial disdain, the industry representatives heard the new chairman announce the following radical upheavals in official AEC philosophy.

  15. CUSP-PINCH DEVICE

    DOEpatents

    Baker, W.R.; Watteau, J.P.H.

    1962-06-01

    An ion-electron plasma heating device of the pinch tube class is designed with novel means for counteracting the instabilities of an ordinary linear pinch discharge. A plasma-forming discharge is created between two spacedapart coaxial electiodes through a gas such as deuterium. A pair of spaced coaxial magnetic field coils encircle the discharge and carry opposing currents so that a magnetic field having a cuspate configuration is created around the plasma, the field being formed after the plasma has been established but before significant instability arises. Thus, containment time is increased and intensified heating is obtained. In addition to the pinch compression heating additional heating is obtained by high-frequency magnetic field modulation. (AEC)

  16. Human amniotic membrane-derived epithelial stem cells display anticancer activity in BALB/c female nude mice bearing disseminated breast cancer xenografts.

    PubMed

    Kang, Nam-Hee; Yi, Bo-Rim; Lim, So Yoon; Hwang, Kyung-A; Baek, Young Seok; Kang, Kyung-Sun; Choi, Kyung-Chul

    2012-06-01

    Breast cancer is one of the most common malignant tumors and the leading cause of mortality among women. In this study, we propose a human stem cell transplantation strategy, an important method for treating various cancers, as a potential breast cancer therapy. To this end, we used human amniotic membrane-derived epithelial stem cells (hAECs) as a cell source for performing human stem cell transplantation. hAECs have multipotent differentiation abilities and possess high proliferative potential. We transplanted hAECs into female BALB/c nude mice bearing tumors originating from MDA-MB-231 breast cancer cells. Co-culturred hAECs and MDA-MB-231 cells at a ratio of 1:4 or 1:8 (tumor cells to stem cells) inhibited breast cancer cell growth by 67.29 and 67.33%, respectively. In the xenograft mouse model, tumor volumes were significantly decreased by 5-flurouracil (5-FU) treatment and two different ratios of hAECs (1:4 and 1:8) by 84.33, 73.88 and 56.89%, respectively. Treatment of nude mice with hAECs (1:4) produced remarkable antitumor effects without any side-effects (e.g., weight loss, death and bruising) compared to the mice that received only 5-FU treatment. Tumor progression was significantly reduced by hAEC treatment compared to the xenograft model. On the other hand, breast tissues (e.g., the epidermis, dermis and reticular layer) appeared to be well-maintained following treatment with hAECs. Taken together, these results provide strong evidence that hAECs can be used as a safe and effective cancer-targeting cytotherapy for treating breast cancer.

  17. Alarmin S100A8 Activates Alveolar Epithelial Cells in the Context of Acute Lung Injury in a TLR4-Dependent Manner.

    PubMed

    Chakraborty, Deblina; Zenker, Stefanie; Rossaint, Jan; Hölscher, Anna; Pohlen, Michele; Zarbock, Alexander; Roth, Johannes; Vogl, Thomas

    2017-01-01

    Alveolar epithelial cells (AECs) are an essential part of the respiratory barrier in lungs for gas exchange and protection against pathogens. Damage to AECs occurs during lung injury and PAMPs/DAMPs have been shown to activate AECs. However, their interplay as well as the mechanism of AECs' activation especially by the alarmin S100A8/A9 is unknown. Thus, our aim was to study the mechanism of activation of AECs (type I and type II) by S100A8 and/or lipopolysaccharide (LPS) and to understand the role of endogenous S100A8/A9 in neutrophil recruitment in the lung. For our studies, we modified a previous protocol for isolation and culturing of murine AECs. Next, we stimulated the cells with S100A8 and/or LPS and analyzed cytokine/chemokine release. We also analyzed the contribution of the known S100-receptors TLR4 and RAGE in AEC activation. In a murine model of lung injury, we investigated the role of S100A8/A9 in neutrophil recruitment to lungs. S100A8 activates type I and type II cells in a dose- and time-dependent manner which could be quantified by the release of IL-6, KC, and MCP-1. We here clearly demonstrate that AEC s are activated by S100A8 via a TLR4-dependent pathway. Surprisingly, RAGE, albeit mainly expressed in lung tissue, plays no role. Additionally, we show that S100A8/A9 is an essential factor for neutrophil recruitment to lungs. We, therefore, conclude that S100A8 promotes acute lung injury via Toll-like receptor 4-dependent activation of AECs.

  18. Tuning of automatic exposure control strength in lumbar spine CT.

    PubMed

    D'Hondt, A; Cornil, A; Bohy, P; De Maertelaer, V; Gevenois, P A; Tack, D

    2014-05-01

    To investigate the impact of tuning the automatic exposure control (AEC) strength curve (specific to Care Dose 4D®; Siemens Healthcare, Forchheim, Germany) from "average" to "strong" on image quality, radiation dose and operator dependency during lumbar spine CT examinations. Two hospitals (H1, H2), both using the same scanners, were considered for two time periods (P1 and P2). During P1, the AEC curve was "average" and radiographers had to select one of two protocols according to the body mass index (BMI): "standard" if BMI <30.0 kg m(-2) (120 kV-330 mAs) or "large" if BMI >30.0 kg m(-2) (140 kV-280 mAs). During P2, the AEC curve was changed to "strong", and all acquisitions were obtained with one protocol (120 kV and 270 mAs). Image quality was scored and patients' diameters calculated for both periods. 497 examinations were analysed. There was no significant difference in mean diameters according to hospitals and periods (p > 0.801) and in quality scores between periods (p > 0.172). There was a significant difference between hospitals regarding how often the "large" protocol was assigned [13 (10%)/132 patients in H1 vs 37 (28%)/133 in H2] (p < 0.001). During P1, volume CT dose index (CTDIvol) was higher in H2 (+13%; p = 0.050). In both hospitals, CTDIvol was reduced between periods (-19.2% in H1 and -29.4% in H2; p < 0.001). An operator dependency in protocol selection, unexplained by patient diameters or highlighted by image quality scores, has been observed. Tuning the AEC curve from average to strong enables suppression of the operator dependency in protocol selection and related dose increase, while preserving image quality. CT acquisition protocols based on weight are responsible for biases in protocol selection. Using an appropriate AEC strength curve reduces the number of protocols to one. Operator dependency of protocol selection is thereby eliminated.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arbique, G; Anderson, J; Guild, J

    Purpose: The National Lung Screening Trial mandated manual low dose CT technique factors, where up to a doubling of radiation output could be used over a regular to large patient size range. Recent guidance from the AAPM and ACR for lung cancer CT screening recommends radiation output adjustment for patient size either through AEC or a manual technique chart. This study evaluated the use of AEC for output control and dose reduction. Methods: The study was performed on a multidetector helical CT scanner (Aquillion ONE, Toshiba Medical) equipped with iterative reconstruction (ADIR-3D), AEC was adjusted with a standard deviation (SD)more » image quality noise index. The protocol SD parameter was incrementally increased to reduce patient population dose while image quality was evaluated by radiologist readers scoring the clinical utility of images on a Likert scale. Results: Plots of effective dose vs. body size (water cylinder diameter reported by the scanner) demonstrate monotonic increase in patient dose with increasing patient size. At the initial SD setting of 19 the average CTDIvol for a standard size patient was ∼ 2.0 mGy (1.2 mSv effective dose). This was reduced to ∼1.0 mGy (0.5 mSv) at an SD of 25 with no noticeable reduction in clinical utility of images as demonstrated by Likert scoring. Plots of effective patient diameter and BMI vs body size indicate that these metrics could also be used for manual technique charts. Conclusion: AEC offered consistent and reliable control of radiation output in this study. Dose for a standard size patient was reduced to one-third of the 3 mGy CTDIvol limit required for ACR accreditation of lung cancer CT screening. Gary Arbique: Research Grant, Toshiba America Medical Systems; Cecelia Brewington: Research Grant, Toshiba America Medical Systems; Di Zhang: Employee, Toshiba America Medical Systems.« less

  20. Human amniotic epithelial cells cultured in substitute serum medium maintain their stem cell characteristics for up to four passages.

    PubMed

    Evron, Ayelet; Goldman, Shlomit; Shalev, Eliezer

    2011-11-01

    The common applied culture medium in which human amniotic epithelial cells (hAECs) maintain their stem cell characteristics contains fetal calf serum (FCS) and thus is not compatible with possible future clinical applications due to the danger of animal derived pathogens. To overcome this problem, we replaced FCS with serum substitute supplement, a serum substitute used in the in vitro fertilization for embryo development, in the common applied culture medium and cultured hAECs in this substitute serum medium (SSM). Purity validation and characterization of freshly isolated and cultured hAECs was assessed through the expression of stem cell specific markers by RT-PCR (gene expression), by immunofluorescence staining and FACS (protein expression). Furthermore, karyotype was performed at passage four in order to exclude possible chromosome anomalies in hAECs cultured in SSM. The differentiation potential of hAECs into the cardiomyogenic lineage was tested through cardiac Troponin T expression by immunohistochemistry. hAECs cultured in SSM maintained expression of all the major pluripotent genes Sox-2, Oct-4 and Nanog as well as the expression of the embryonic stem cell specific surface antigens SSEA-4, SSEA-3 and TRA-1-60 over four passages. Using cardiac differentiation medium containing 10% serum substitute supplement, hAECs differentiated into cardiac troponin T expressing cells. We can conclude that, hAECs maintain their stem cell characteristics when cultured in SSM for up to 4 passages. This makes possible future clinical applications of these cells more feasible.

  1. Operation DOMINIC II, Shots LITTLE FELLER II, JOHNIE BOY, SMALL BOY, LITTLE FELLER I, 7 July-17 July 1962. Technical report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ponton, J.; Maag, C.; Rohrer, S.

    1983-01-31

    This report describes the activities of an estimated 3,000 DOD personnel, both military and civilian, in Operation DOMINIC II, the eighth peacetime series of nuclear weapons tests, conducted in Nevada from 7 July through 17 July 1962. Activities engaging DOD personnel included the Exercise IVY FLATS troop maneuver, joint DASA and AEC scientific experiments to evaluate the effects of the nuclear devices, and air support.

  2. DIGITAL Q METER

    DOEpatents

    Briscoe, W.L.

    1962-02-13

    A digital Q meter is described for measuring the Q of mechanical or electrical devices. The meter comprises in combination a transducer coupled to an input amplifier, and an upper and lower level discriminator coupled to the amplifier and having their outputs coupled to an anticoincidence gate. The output of the gate is connected to a scaler. The lower level discriminator is adjusted to a threshold level of 36.8 percent of the operating threshold level of the upper level discriminator. (AEC)

  3. AST Critical Propulsion and Noise Reduction Technologies for Future Commercial Subsonic Engines: Separate-Flow Exhaust System Noise Reduction Concept Evaluation

    NASA Technical Reports Server (NTRS)

    Janardan, B. A.; Hoff, G. E.; Barter, J. W.; Martens, S.; Gliebe, P. R.; Mengle, V.; Dalton, W. N.; Saiyed, Naseem (Technical Monitor)

    2000-01-01

    This report describes the work performed by General Electric Aircraft Engines (GEAE) and Allison Engine Company (AEC) on NASA Contract NAS3-27720 AoI 14.3. The objective of this contract was to generate quality jet noise acoustic data for separate-flow nozzle models and to design and verify new jet-noise-reduction concepts over a range of simulated engine cycles and flight conditions. Five baseline axisymmetric separate-flow nozzle models having bypass ratios of five and eight with internal and external plugs and 11 different mixing-enhancer model nozzles (including chevrons, vortex-generator doublets, and a tongue mixer) were designed and tested in model scale. Using available core and fan nozzle hardware in various combinations, 28 GEAE/AEC separate-flow nozzle/mixing-enhancer configurations were acoustically evaluated in the NASA Glenn Research Center Aeroacoustic and Propulsion Laboratory. This report describes model nozzle features, facility and data acquisition/reduction procedures, the test matrix, and measured acoustic data analyses. A number of tested core and fan mixing enhancer devices and combinations of devices gave significant jet noise reduction relative to separate-flow baseline nozzles. Inward-flip and alternating-flip core chevrons combined with a straight-chevron fan nozzle exceeded the NASA stretch goal of 3 EPNdB jet noise reduction at typical sideline certification conditions.

  4. FAST ACTING CURRENT SWITCH

    DOEpatents

    Batzer, T.H.; Cummings, D.B.; Ryan, J.F.

    1962-05-22

    A high-current, fast-acting switch is designed for utilization as a crowbar switch in a high-current circuit such as used to generate the magnetic confinement field of a plasma-confining and heat device, e.g., Pyrotron. The device particularly comprises a cylindrical housing containing two stationary, cylindrical contacts between which a movable contact is bridged to close the switch. The movable contact is actuated by a differential-pressure, airdriven piston assembly also within the housing. To absorb the acceleration (and the shock imparted to the device by the rapidly driven, movable contact), an adjustable air buffer assembly is provided, integrally connected to the movable contact and piston assembly. Various safety locks and circuit-synchronizing means are also provided to permit proper cooperation of the invention and the high-current circuit in which it is installed. (AEC)

  5. DRIFT CONTROL IN AN ANALYTICAL GAMMA RAY SPECTROMETER

    DOEpatents

    Fite, L.E.

    1963-08-20

    A device for automatically and continuously controlling the over-all drift of a multi-channel analyzer so as to permit the accurate processing of spectrometric analytical data by a digital computer is described. Two sources of reference pulses, one of which is stored in the lower channels and the other being stored in the higher channels of a 256 channel analyzer, are provided. The reference pulses are processed in the same manner as the data pulses. The channels that should contain the reference pulses and the adjacent channels above and below those channels are monitored by comparison circuits such that any drift, upward or downward, of the reference pulses is detected to effect a change in high voltage supply in response to a drift in the upper channel, and to effect a change in the lower discriminator level of the analog to digital converter of the analyzer in response to a drift in the lower channel, thereby maintaining the pulses in the proper channels. (AEC)

  6. The clinical course of asymptomatic esophageal candidiasis incidentally diagnosed in general health inspection.

    PubMed

    Lee, Sang Pyo; Sung, In-Kyung; Kim, Jeong Hwan; Lee, Sun-Young; Park, Hyung Seok; Shim, Chan Sup

    2015-01-01

    Esophageal candidiasis mostly occurs in the immunocompromised host. However, it may also affect healthy people and is frequently asymptomatic. The clinical significance of asymptomatic esophageal candidiasis (AEC) is still unclear. The aims of the study were to investigate the prevalence of AEC during health inspection and to identify its predisposing factors and clinical significance. A total of 49,497 subjects who underwent a health inspection that included upper endoscopy were enrolled. We retrospectively reviewed the subject's self-reporting questionnaires, medical records and endoscopic findings. We considered "long-term" follow-up to be >6 months with at least one more follow-up endoscopy. One hundred and seventy (0.4%) subjects were endoscopically diagnosed as esophageal candidiasis and 141 subjects were AEC. Multivariate analysis revealed that old age (≥60 years) was an independent risk factor for AEC (OR, 1.862, p = 0.005). The number of subjects with long-term follow-up was 79 (195.3 person-years). Among these, AEC of 64 subjects (81.0%) had disappeared on the follow-up endoscopy and was not recurrent. The other 15 subjects had AEC diagnosed more than once on the follow-up endoscopy, and 5 of them were spontaneously healed during the follow-up period. The remaining 10 subjects whose candidiasis was sustained up to the last endoscopy did not complain of symptoms during the follow-up period, and their endoscopic findings did not worsen. AEC is rare and old age is the only risk factor. AEC does not require medical care because it is a self-limited disease.

  7. Can access to spirometry in asthma education centres influence the referral rate by primary physicians for education?

    PubMed Central

    Labrecque, M; Lavallée, M; Beauchesne, MF; Cartier, A; Boulet, LP

    2006-01-01

    BACKGROUND AND OBJECTIVES: Asthma remains uncontrolled in a large number of asthmatic patients. Recent surveys have shown that a minority of asthmatic patients are referred to asthma educators. The objective of the present study was to assess the influence of increased access to spirometry in asthma education centres (AECs) on the rate of patient referrals to these centres by general practitioners. METHODS: A one-year, prospective, randomized, multicentric, parallel group study was conducted over two consecutive periods of six months each, with added spirometry being offered in the second six-month period to the experimental group. Ten AECs were enrolled in the project. An advertisement describing the AECs’ services was sent by mail to a total of 303 general practitioners at the start of each period, inviting them to refer their patients. Measures of the frequency of medical referrals to the AECs were assessed for each period. RESULTS: The group of AECs randomly selected for spirometry in the second six-month period received 48 medical referrals during the first period and 32 during the second one, following proposed spirometry. AECs that had not offered spirometry received five referrals during the first period and seven during the second period. One AEC withdrew a few weeks after the study began and others encountered administrative problems, reducing their ability to provide interventions. CONCLUSIONS: Referral to AECs is not yet integrated into the primary care of asthma and offering more rapid access to spirometry in the AECs does not seem to be a significant incentive for such referrals. PMID:17149461

  8. Synthetic Bone Substitute Engineered with Amniotic Epithelial Cells Enhances Bone Regeneration after Maxillary Sinus Augmentation

    PubMed Central

    Barboni, Barbara; Mangano, Carlo; Valbonetti, Luca; Marruchella, Giuseppe; Berardinelli, Paolo; Martelli, Alessandra; Muttini, Aurelio; Mauro, Annunziata; Bedini, Rossella; Turriani, Maura; Pecci, Raffaella; Nardinocchi, Delia; Zizzari, Vincenzo Luca; Tetè, Stefano; Piattelli, Adriano; Mattioli, Mauro

    2013-01-01

    Background Evidence has been provided that a cell-based therapy combined with the use of bioactive materials may significantly improve bone regeneration prior to dental implant, although the identification of an ideal source of progenitor/stem cells remains to be determined. Aim In the present research, the bone regenerative property of an emerging source of progenitor cells, the amniotic epithelial cells (AEC), loaded on a calcium-phosphate synthetic bone substitute, made by direct rapid prototyping (rPT) technique, was evaluated in an animal study. Material And Methods Two blocks of synthetic bone substitute (∼0.14 cm3), alone or engineered with 1×106 ovine AEC (oAEC), were grafted bilaterally into maxillary sinuses of six adult sheep, an animal model chosen for its high translational value in dentistry. The sheep were then randomly divided into two groups and sacrificed at 45 and 90 days post implantation (p.i.). Tissue regeneration was evaluated in the sinus explants by micro-computer tomography (micro-CT), morphological, morphometric and biochemical analyses. Results And Conclusions The obtained data suggest that scaffold integration and bone deposition are positively influenced by allotransplantated oAEC. Sinus explants derived from sheep grafted with oAEC engineered scaffolds displayed a reduced fibrotic reaction, a limited inflammatory response and an accelerated process of angiogenesis. In addition, the presence of oAEC significantly stimulated osteogenesis either by enhancing bone deposition or making more extent the foci of bone nucleation. Besides the modulatory role played by oAEC in the crucial events successfully guiding tissue regeneration (angiogenesis, vascular endothelial growth factor expression and inflammation), data provided herein show that oAEC were also able to directly participate in the process of bone deposition, as suggested by the presence of oAEC entrapped within the newly deposited osteoid matrix and by their ability to switch-on the expression of a specific bone-related protein (osteocalcin, OCN) when transplanted into host tissues. PMID:23696804

  9. CONTROL ROD

    DOEpatents

    Walker, D.E.; Matras, S.

    1963-04-30

    This patent shows a method of making a fuel or control rod for a nuclear reactor. Fuel or control material is placed within a tube and plugs of porous metal wool are inserted at both ends. The metal wool is then compacted and the tube compressed around it as by swaging, thereby making the plugs liquid- impervious but gas-pervious. (AEC)

  10. Telomere dysfunction in alveolar epithelial cells causes lung remodeling and fibrosis

    PubMed Central

    Naikawadi, Ram P.; Disayabutr, Supparerk; Mallavia, Benat; Donne, Matthew L.; Green, Gary; La, Janet L.; Rock, Jason R.; Looney, Mark R.; Wolters, Paul J.

    2016-01-01

    Telomeres are short in type II alveolar epithelial cells (AECs) of patients with idiopathic pulmonary fibrosis (IPF). Whether dysfunctional telomeres contribute directly to development of lung fibrosis remains unknown. The objective of this study was to investigate whether telomere dysfunction in type II AECs, mediated by deletion of the telomere shelterin protein TRF1, leads to pulmonary fibrosis in mice (SPC-Cre TRF1fl/fl mice). Deletion of TRF1 in type II AECs for 2 weeks increased γH2AX DNA damage foci, but not histopathologic changes in the lung. Deletion of TRF1 in type II AECs for up to 9 months resulted in short telomeres and lung remodeling characterized by increased numbers of type II AECs, α-smooth muscle actin+ mesenchymal cells, collagen deposition, and accumulation of senescence-associated β-galactosidase+ lung epithelial cells. Deletion of TRF1 in collagen-expressing cells caused pulmonary edema, but not fibrosis. These results demonstrate that prolonged telomere dysfunction in type II AECs, but not collagen-expressing cells, leads to age-dependent lung remodeling and fibrosis. We conclude that telomere dysfunction in type II AECs is sufficient to cause lung fibrosis, and may be a dominant molecular defect causing IPF. SPC-Cre TRF1fl/fl mice will be useful for assessing cellular and molecular mechanisms of lung fibrosis mediated by telomere dysfunction. PMID:27699234

  11. APPARATUS FOR THE DENSIFICATION AND ENERGIZATION OF CHARGED PARTICLES

    DOEpatents

    Post, R.F.; Coensgen, F.H.

    1962-12-18

    This patent relates to a device for materially increasing the energy and density of a plasma to produce conditions commensurate with the establishment and promotion of controlled thermonuclear reactions. To this end the device employs three successive stages of magnetic compression, each stage having magnetic mirrors to compress a plasma, the mirrors being moveable to transfer the plasma to successive stages for further compression. Accordingly, a plasma introduced to the first stage is increased in density and energy in stepwide fashion by virtue of the magnetic compression in the successive stages such that the plasma upon reaching the last stage is of extremely high energy and density commensurate the plasma particles undergoing thermonuclear reactions. The principal novelty of the device resides in the provision of a unidirectional magnetic field which increases in stepwise fashion in coaxially communicating compression chambers of progressively decreasing lengths and diameters. Pulsed magnetic fields are superimposed upon the undirectional field and are manipulated to establish resultant magnetic compression fields which increase in intensity and progressively move, with respect to time, through the compression chambers in the direction of the smallest one thereof. The resultant field in the last compression chamber is hence of relatively high intensity, and the density and energy of the plasma confined therein are correspondingly high. (AEC)

  12. History of the United States Atomic Energy Commission. Volume II. 1947 / 1952, Atomic Shield

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hewlett, Richard G.; Duncan, Francis

    1972-01-01

    Sponsored by the Historical Advisory Committee of the Atomic Energy Commission (AEC), this 2-volume series provides an unclassified history of the AEC. Volume I is subtitled ''The New World'' and covers the AEC from 1939 through 1946. This volume, Volume II, is subtitled ''Atomic Shield'' and covers the years 1947 through 1952.

  13. History of the United States Atomic Energy Commission. Volume I. 1939 / 1946, The New World

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hewlett, Richard G.; Anderson, Jr., Oscar E.

    1962-01-01

    Sponsored by the Historical Advisory Committee of the Atomic Energy Commission (AEC), this 2-volume series provides an unclassified history of the AEC. This volume is subtitled ''The New World'' and covers the AEC from 1939 through 1946. Volume II, is subtitled ''Atomic Shield'' and covers the years 1947 through 1952.

  14. Risks Associated with Federal Construction Projects

    DTIC Science & Technology

    2011-06-01

    awarding contracts for construction projects (USACE, 2010). BIM offers a method to effectively design a facility while maximizing work performance during...includes Requirements, Programming, Funding, Solicitation, AEC Evaluation, Award , Project Validation, Design and Construction, and Project Management...includes the Solicitation, AEC Evaluation, and Award Steps. In this Phase, BIM is only used in the Solicitation and the AEC Evaluation steps

  15. APPARATUS FOR GRINDING SPHERICAL BODIES

    DOEpatents

    Burch, R.F. Jr.

    1963-09-24

    A relatively inexpensive device is described for grinding rough ceramic bodies into accurate spherical shapes using a conventional drill press and a belt sander. A horizontal disk with an abrasive-surfaced recess in its lower face is mounted eccentrically on a vertical shaft which is forced downward against a stop by a spring. Bodies to be ground are placed in the recess and are subjected to the abrasive action of the belt sander as the disk is rotated by the drill press. (AEC)

  16. METHOD AND APPARATUS FOR MEASURING RADIATION

    DOEpatents

    Reeder, S.D.

    1962-04-17

    A chemical dosimeter for measuring the progress of a radiation-induced oxidation-reduction reaction is described. The dosimeter comprises a container filled with an aqueous chemical oxidation-reduction system which reacts quantitatively to the radiation. An anode of the group consisting of antimony and tungsten and a cathode of the group consisting of gold and platnium are inserted into the system. Means are provided to stir the system and a potential sensing device is connected across the anode and cathode to detect voltage changes. (AEC)

  17. PERSONAL RADIATION MONITOR

    DOEpatents

    Dilworth, R.H.; Borkowski, C.J.

    1961-12-26

    A transistorized, fountain pen type radiation monitor to be worn on the person is described. Radiation produces both light flashes in a small bulb and an audible warning tone, the frequency of both the tone and light flashes being proportional to radiation intensity. The device is powered by a battery and a blocking oscillator step-up power supply The oscillator frequency- is regulated to be proportional to the radiation intensity, to provide adequate power in high radiation fields, yet minimize battery drain at low operating intensities. (AEC)

  18. Controlling the atom. The beginnings of nuclear regulation 1946--1962

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mazuzan, G.T.; Walker, J.S.

    This book traces the early history of nuclear power regulation in the US. It focuses on the Atomic Energy Commission (AEC), the federal agency that until 1975 was primarily responsible for planning and carrying out programs to protect public health and safety from the hazards of the civilian use of nuclear energy. It also describes the role of other groups that figured significantly in the development of regulatory policies, including the congressional Joint Committee on Atomic Energy, federal agencies other than the AEC, state governments, the nuclear industry, and scientific organizations. And it considers changes in public perceptions of andmore » attitudes toward atomic energy and the dangers of radiation exposure. The context in which regulatory programs evolved is a rich and complex mixture of political, legislative, legal, technological, scientific, and administrative history. The basic purpose of this book is to provide the Nuclear Regulatory Commission (NRC), which inherited responsibility for nuclear safety after Congress disbanded the AEC, and the general public with information on the historical antecedents and background of regulatory issues.« less

  19. Alarmin S100A8 Activates Alveolar Epithelial Cells in the Context of Acute Lung Injury in a TLR4-Dependent Manner

    PubMed Central

    Chakraborty, Deblina; Zenker, Stefanie; Rossaint, Jan; Hölscher, Anna; Pohlen, Michele; Zarbock, Alexander; Roth, Johannes; Vogl, Thomas

    2017-01-01

    Alveolar epithelial cells (AECs) are an essential part of the respiratory barrier in lungs for gas exchange and protection against pathogens. Damage to AECs occurs during lung injury and PAMPs/DAMPs have been shown to activate AECs. However, their interplay as well as the mechanism of AECs’ activation especially by the alarmin S100A8/A9 is unknown. Thus, our aim was to study the mechanism of activation of AECs (type I and type II) by S100A8 and/or lipopolysaccharide (LPS) and to understand the role of endogenous S100A8/A9 in neutrophil recruitment in the lung. For our studies, we modified a previous protocol for isolation and culturing of murine AECs. Next, we stimulated the cells with S100A8 and/or LPS and analyzed cytokine/chemokine release. We also analyzed the contribution of the known S100-receptors TLR4 and RAGE in AEC activation. In a murine model of lung injury, we investigated the role of S100A8/A9 in neutrophil recruitment to lungs. S100A8 activates type I and type II cells in a dose- and time-dependent manner which could be quantified by the release of IL-6, KC, and MCP-1. We here clearly demonstrate that AEC s are activated by S100A8 via a TLR4-dependent pathway. Surprisingly, RAGE, albeit mainly expressed in lung tissue, plays no role. Additionally, we show that S100A8/A9 is an essential factor for neutrophil recruitment to lungs. We, therefore, conclude that S100A8 promotes acute lung injury via Toll-like receptor 4-dependent activation of AECs. PMID:29180999

  20. Alveolar Macrophages Prevent Lethal Influenza Pneumonia By Inhibiting Infection Of Type-1 Alveolar Epithelial Cells

    PubMed Central

    Cardani, Amber; Boulton, Adam; Kim, Taeg S.; Braciale, Thomas J.

    2017-01-01

    The Influenza A virus (IAV) is a major human pathogen that produces significant morbidity and mortality. To explore the contribution of alveolar macrophages (AlvMΦs) in regulating the severity of IAV infection we employed a murine model in which the Core Binding Factor Beta gene is conditionally disrupted in myeloid cells. These mice exhibit a selective deficiency in AlvMΦs. Following IAV infection these AlvMΦ deficient mice developed severe diffuse alveolar damage, lethal respiratory compromise, and consequent lethality. Lethal injury in these mice resulted from increased infection of their Type-1 Alveolar Epithelial Cells (T1AECs) and the subsequent elimination of the infected T1AECs by the adaptive immune T cell response. Further analysis indicated AlvMΦ-mediated suppression of the cysteinyl leukotriene (cysLT) pathway genes in T1AECs in vivo and in vitro. Inhibition of the cysLT pathway enzymes in a T1AECs cell line reduced the susceptibility of T1AECs to IAV infection, suggesting that AlvMΦ-mediated suppression of this pathway contributes to the resistance of T1AECs to IAV infection. Furthermore, inhibition of the cysLT pathway enzymes, as well as blockade of the cysteinyl leukotriene receptors in the AlvMΦ deficient mice reduced the susceptibility of their T1AECs to IAV infection and protected these mice from lethal infection. These results suggest that AlvMΦs may utilize a previously unappreciated mechanism to protect T1AECs against IAV infection, and thereby reduce the severity of infection. The findings further suggest that the cysLT pathway and the receptors for cysLT metabolites represent potential therapeutic targets in severe IAV infection. PMID:28085958

  1. Primary Airway Epithelial Cell Gene Editing Using CRISPR-Cas9.

    PubMed

    Everman, Jamie L; Rios, Cydney; Seibold, Max A

    2018-01-01

    The adaptation of the clustered regularly interspaced short palindromic repeats (CRISPR) and CRISPR associated endonuclease 9 (CRISPR-Cas9) machinery from prokaryotic organisms has resulted in a gene editing system that is highly versatile, easily constructed, and can be leveraged to generate human cells knocked out (KO) for a specific gene. While standard transfection techniques can be used for the introduction of CRISPR-Cas9 expression cassettes to many cell types, delivery by this method is not efficient in many primary cell types, including primary human airway epithelial cells (AECs). More efficient delivery in AECs can be achieved through lentiviral-mediated transduction, allowing the CRISPR-Cas9 system to be integrated into the genome of the cell, resulting in stable expression of the nuclease machinery and increasing editing rates. In parallel, advancements have been made in the culture, expansion, selection, and differentiation of AECs, which allow the robust generation of a bulk edited AEC population from transduced cells. Applying these methods, we detail here our latest protocol to generate mucociliary epithelial cultures knocked out for a specific gene from donor-isolated primary human basal airway epithelial cells. This protocol includes methods to: (1) design and generate lentivirus which targets a specific gene for KO with CRISPR-Cas9 machinery, (2) efficiently transduce AECs, (3) culture and select for a bulk edited AEC population, (4) molecularly screen AECs for Cas9 cutting and specific sequence edits, and (5) further expand and differentiate edited cells to a mucociliary airway epithelial culture. The AEC knockouts generated using this protocol provide an excellent primary cell model system with which to characterize the function of genes involved in airway dysfunction and disease.

  2. Results of the Radiological Survey of the Iowa Army Ammunition Plant, Middletown, Iowa

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murray, M.E.

    2001-07-17

    At the request of the U.S. Department of Energy (DOE), a team from Oak Ridge National Laboratory conducted an indoor radiological survey of property at the Iowa Army Ammunition Plant (IAAAP), Middletown, Iowa in June 2000. The purpose of the survey was to determine if radioactive residuals resulting from previous Atomic Energy Commission (AEC) activities were present inside selected Line 1 buildings at the IAAAP and conduct sampling in those areas of previous AEC operations that utilized radioactive components at some point during the manufacturing process, in order to evaluate any possible immediate health hazards and to collect sufficient informationmore » to determine the next type of survey. The AEC occupied portions of IAAAP from 1947 to 1975 to assemble nuclear weapons. The surveyed areas were identified through interviews with current and former IAAAP employees who had worked at the plant during AEC's tenure, and from AEC records.« less

  3. Reduction of FR900525 using an S-(2-aminoethyl) l-cysteine-resistant mutant.

    PubMed

    Shimizu, Shiho; Futase, Ayako; Yokoyama, Tatsuya; Ueda, Satoshi; Honda, Hiroyuki

    2017-06-01

    FK506 (tacrolimus), a macrolide compound with immunosuppressant activity, has been proven to have clinical importance and has been manufactured industrially since 1993 by using mutants with high FK506-production ability; these mutants have been developed from the wild strain Streptomyces tsukubaensis No. 9993. FR900525 is one of the by-products of FK506 production. However, there was no effective industrial method to separate FR900525 from FK506 due to the structural similarity between the two compounds. Therefore, reducing the level of FR900525 was a serious problem in the industrial strain A. In this study, we aimed to reduce the FR900525 production. We first determined that pipecolic acid level was a critical parameter for controlling FR900525 production in strain A. S-(2-Aminoethyl) l-cysteine (AEC)-resistant mutants has been reported to increase lysine productivity successfully in a variety of lysine-producing microorganisms. Therefore, next, we applied a selection of AEC-resistant mutants to enhance pipecolic acid biosynthesis. Finally, four AEC-resistant mutants were obtained from strain A using ultraviolet irradiation, and three of them showed less FR900525 productivity compared to the parental strain A. Our findings indicated that AEC resistance was effective phenotype marker for increasing pipecolic acid productivity and for reducing FR900525 production in S. tsukubaensis. Thus, our study provides an efficient method for reducing FR90025 level during FK506 biosynthesis. Copyright © 2017 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  4. Temporal focusing-based widefield multiphoton microscopy with spatially modulated illumination for biotissue imaging.

    PubMed

    Chang, Chia-Yuan; Lin, Cheng-Han; Lin, Chun-Yu; Sie, Yong-Da; Hu, Yvonne Yuling; Tsai, Sheng-Feng; Chen, Shean-Jen

    2018-01-01

    A developed temporal focusing-based multiphoton excitation microscope (TFMPEM) has a digital micromirror device (DMD) which is adopted not only as a blazed grating for light spatial dispersion but also for patterned illumination simultaneously. Herein, the TFMPEM has been extended to implement spatially modulated illumination at structured frequency and orientation to increase the beam coverage at the back-focal aperture of the objective lens. The axial excitation confinement (AEC) of TFMPEM can be condensed from 3.0 μm to 1.5 μm for a 50 % improvement. By using the TFMPEM with HiLo technique as two structured illuminations at the same spatial frequency but different orientation, reconstructed biotissue images according to the condensed AEC structured illumination are shown obviously superior in contrast and better scattering suppression. Picture: TPEF images of the eosin-stained mouse cerebellar cortex by conventional TFMPEM (left), and the TFMPEM with HiLo technique as 1.09 μm -1 spatially modulated illumination at 90° (center) and 0° (right) orientations. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. MOLTEN PLUTONIUM FUELED FAST BREEDER REACTOR

    DOEpatents

    Kiehn, R.M.; King, L.D.P.; Peterson, R.E.; Swickard, E.O. Jr.

    1962-06-26

    A description is given of a nuclear fast reactor fueled with molten plutonium containing about 20 kg of plutonium in a tantalum container, cooled by circulating liquid sodium at about 600 to 650 deg C, having a large negative temperature coefficient of reactivity, and control rods and movable reflector for criticality control. (AEC)

  6. Individually ventilated cages cause chronic low-grade hypoxia impacting mice hematologically and behaviorally

    PubMed Central

    York, Jason M.; McDaniel, Allison W.; Blevins, Neil A.; Guillet, Riley R.; Allison, Sarah O.; Cengel, Keith A.; Freund, Gregory G.

    2012-01-01

    Use of individually ventilated caging (IVC) systems for mouse-based laboratory investigation has dramatically increased. We found that without mice present, intra-cage oxygen concentration was comparable (21%) between IVC housing and ambient environment caging (AEC) that used wire top lids. However, when mice were housed 4-to-a-cage for 1 week, intra-cage oxygen dropped to 20.5% in IVC housing as compared to 21% for AEC housing. IVC intra-cage humidity was also elevated relative to AEC housing. Mice raised in IVC housing as compared to mice raised in AEC housing had higher RBC mass, hematocrit and hemoglobin concentrations. They also had elevated platelet counts but lower white blood cell counts. IVC mice relative to AEC mice had increased saccharin preference and increased fluid consumption but similar locomotion, food intake, social exploration and novel object recognition when tested in an AEC environment. Taken together, these data indicate that ventilated caging systems can have a 0.5% reduction from ambient oxygen concentration that is coupled to mouse red blood cell indices indicative of chronic exposure to a hypoxia. Importantly, IVC housing can impact behavioral testing for depressive-like behavior. PMID:22561683

  7. CONTROL SYSTEM

    DOEpatents

    Shannon, R.H.; Williamson, H.E.

    1962-10-30

    A boiling water type nuclear reactor power system having improved means of control is described. These means include provisions for either heating the coolant-moderator prior to entry into the reactor or shunting the coolantmoderator around the heating means in response to the demand from the heat engine. These provisions are in addition to means for withdrawing the control rods from the reactor. (AEC)

  8. AE-C attitude determination and control prelaunch analysis and operations plan

    NASA Technical Reports Server (NTRS)

    Werking, R. D.; Headrick, R. D.; Manders, C. F.; Woolley, R. D.

    1973-01-01

    A description of attitude control support being supplied by the Mission and Data Operations Directorate is presented. Included are descriptions of the computer programs being used to support the missions for attitude determination, prediction, and control. In addition, descriptions of the operating procedures which will be used to accomplish mission objectives are provided.

  9. A Method for the Automatic Exposure Control in Pediatric Abdominal CT: Application to the Standard Deviation Value and Tube Current Methods by Using Patient's Age and Body Size.

    PubMed

    Furuya, Ken; Akiyama, Shinji; Nambu, Atushi; Suzuki, Yutaka; Hasebe, Yuusuke

    2017-01-01

    We aimed to apply the pediatric abdominal CT protocol of Donnelly et al. in the United States to the pediatric abdominal CT-AEC. Examining CT images of 100 children, we found that the sectional area of the hepatic portal region (y) was strongly correlated with the body weight (x) as follows: y=7.14x + 84.39 (correlation coefficient=0.9574). We scanned an elliptical cone phantom that simulates the human body using a pediatric abdominal CT scanning method of Donnelly et al. in, and measured SD values. We further scanned the same phantom under the settings for adult CT-AEC scan and obtained the relationship between the sectional areas (y) and the SD values. Using these results, we obtained the following preset noise factors for CT-AEC at each body weight range: 6.90 at 4.5-8.9 kg, 8.40 at 9.0-17.9 kg, 8.68 at 18.0-26.9 kg, 9.89 at 27.0-35.9 kg, 12.22 at 36.0-45.0 kg, 13.52 at 45.1-70.0 kg, 15.29 at more than 70 kg. From the relation between age, weight and the distance of liver and tuber ischiadicum of 500 children, we obtained the CTDI vol values and DLP values under the scanning protocol of Donnelly et al. Almost all of DRL from these values turned out to be smaller than the DRL data of IAEA and various countries. Thus, by setting the maximum current values of CT-AEC to be the Donnelly et al.'s age-wise current values, and using our weight-wise noise factors, we think we can perform pediatric abdominal CT-AEC scans that are consistent with the same radiation safety and the image quality as those proposed by Donnelly et al.

  10. EXPRESSION OF NeuGc ON PIG CORNEAS AND ITS POTENTIAL SIGNIFICANCE IN PIG CORNEAL XENOTRANSPLANTATION

    PubMed Central

    Lee, Whayoung; Miyagawa, Yuko; Long, Cassandra; Ekser, Burcin; Walters, Eric; Ramsoondar, Jagdeece; Ayares, David; Tector, A. Joseph; Cooper, David K. C.; Hara, Hidetaka

    2016-01-01

    Purpose Pigs expressing neither galactose-α1,3-galactose (Gal) nor N-glycolylneuraminic acid (NeuGc) take xenotransplantation one step closer to the clinic. Our aims were (i) to document the lack of NeuGc expression on corneas and aortas, and cultured endothelial cells (aortic [AECs]; corneal [CECs]) of GTKO/NeuGcKO pigs, and (ii) to investigate whether the absence of NeuGc reduced human antibody binding to the tissues and cells. Methods Wild-type (WT), GTKO, and GTKO/NeuGcKO pig were used for the study. Human tissues and cultured cells were negative controls. Immunofluorescence staining was performed using anti-Gal and anti-NeuGc antibodies, and to determine human IgM and IgG binding to tissues. Flow cytometric analysis was used to determine Gal and NeuGc expression on cultured CECs and AECs and to measure human IgM/IgG binding to these cells. Results Both Gal and NeuGc were detected on WT pig corneas and aortas. Although GTKO pigs expressed NeuGc, neither human nor GTKO/NeuGcKO pigs expressed Gal or NeuGc. Human IgM/IgG binding to corneas and aortas from GTKO and GTKO/NeuGcKO pigs was reduced compared to binding to WT pigs. Human antibody binding to GTKO/NeuGcKO AECs was significantly less than to GTKO AECs, but there was no significant difference in binding between GTKO and GTKO/NeuGcKO CECs. Conclusions The absence of NeuGc on GTKO aortic tissue and AECs is associated with reduced human antibody binding, and possibly will provide better outcome in clinical xenotransplantation using vascularized organs. For clinical corneal xenotransplantation, the absence of NeuGc expression on GTKO/NeuGcKO pig corneas may not prove an advantage over GTKO corneas. PMID:26418433

  11. SU-E-I-68: Practical Considerations On Implementation of the Image Gently Pediatric CT Protocols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, J; Adams, C; Lumby, C

    Purpose: One limitation associated with the Image Gently pediatric CT protocols is practical implementation of the recommended manual techniques. Inconsistency as a result of different practice is a possibility among technologist. An additional concern is the added risk of data error that would result in over or underexposure. The Automatic Exposure Control (AEC) features automatically reduce radiation for children. However, they do not work efficiently for the patients of very small size and relative large size. This study aims to implement the Image Gently pediatric CT protocols in the practical setting while maintaining the use of AEC features for pediatricmore » patients of varying size. Methods: Anthropomorphological abdomen phantoms were scanned in a CT scanner using the Image Gently pediatric protocols, the AEC technique with a fixed adult baseline, and automatic protocols with various baselines. The baselines were adjusted corresponding to patient age, weight and posterioranterior thickness to match the Image Gently pediatric CT manual techniques. CTDIvol was recorded for each examination. Image noise was measured and recorded for image quality comparison. Clinical images were evaluated by pediatric radiologists. Results: By adjusting vendor default baselines used in the automatic techniques, radiation dose and image quality can match those of the Image Gently manual techniques. In practice, this can be achieved by dividing pediatric patients into three major groups for technologist reference: infant, small child, and large child. Further division can be done but will increase the number of CT protocols. For each group, AEC can efficiently adjust acquisition techniques for children. This implementation significantly overcomes the limitation of the Image Gently manual techniques. Conclusion: Considering the effectiveness in clinical practice, Image Gently Pediatric CT protocols can be implemented in accordance with AEC techniques, with adjusted baselines, to achieve the goal of providing the most appropriate radiation dose for pediatric patients of varying sizes.« less

  12. Effects of human rhinovirus on epithelial barrier integrity and function in children with asthma.

    PubMed

    Looi, K; Buckley, A G; Rigby, P J; Garratt, L W; Iosifidis, T; Zosky, G R; Larcombe, A N; Lannigan, F J; Ling, K-M; Martinovich, K M; Kicic-Starcevich, E; Shaw, N C; Sutanto, E N; Knight, D A; Kicic, A; Stick, S M

    2018-05-01

    Bronchial epithelial tight junctions (TJ) have been extensively assessed in healthy airway epithelium. However, no studies have yet assessed the effect of human rhinovirus (HRV) infection on the expression and resultant barrier function in epithelial tight junctions (TJ) in childhood asthma. To investigate the impact of HRV infection on airway epithelial TJ expression and barrier function in airway epithelial cells (AECs) of children with and without asthma. Furthermore, to test the hypothesis that barrier integrity and function is compromised to a greater extent by HRV in AECs from asthmatic children. Primary AECs were obtained from children with and without asthma, differentiated into air-liquid interface (ALI) cultures and infected with rhinovirus. Expression of claudin-1, occludin and zonula occluden-1 (ZO-1) was assessed via qPCR, immunocytochemistry (ICC), in-cell western (ICW) and confocal microscopy. Barrier function was assessed by transepithelial electrical resistance (TER; R T ) and permeability to fluorescent dextran. Basal TJ gene expression of claudin-1 and occludin was significantly upregulated in asthmatic children compared to non-asthmatics; however, no difference was seen with ZO-1. Interestingly, claudin-1, occludin and ZO-1 protein expression was significantly reduced in AEC of asthmatic children compared to non-asthmatic controls suggesting possible post-transcriptional inherent differences. HRV infection resulted in a transient dissociation of TJ and airway barrier integrity in non-asthmatic children. Although similar dissociation of TJ was observed in asthmatic children, a significant and sustained reduction in TJ expression concurrent with both a significant decrease in TER and an increase in permeability in asthmatic children was observed. This study demonstrates novel intrinsic differences in TJ gene and protein expression between AEC of children with and without asthma. Furthermore, it correlates directly the relationship between HRV infection and the resultant dissociation of epithelial TJ that causes a continued altered barrier function in children with asthma. © 2018 John Wiley & Sons Ltd.

  13. Efficient use of automatic exposure control systems in computed tomography requires correct patient positioning.

    PubMed

    Gudjonsdottir, J; Svensson, J R; Campling, S; Brennan, P C; Jonsdottir, B

    2009-11-01

    Image quality and radiation dose to the patient are important factors in computed tomography (CT). To provide constant image quality, tube current modulation (TCM) performed by automatic exposure control (AEC) adjusts the tube current to the patient's size and shape. To evaluate the effects of patient centering on tube current-time product (mAs) and image noise. An oval-shaped acrylic phantom was scanned in various off-center positions, at 30-mm intervals within a 500-mm field of view, using three different CT scanners. Acquisition parameters were similar to routine abdomen examinations at each site. The mAs was recorded and noise measured in the images. The correlation of mAs and noise with position was calculated using Pearson correlation. In all three scanners, the mAs delivered by the AEC changed with y-position of the phantom (P<0.001), with correlation values of 0.98 for scanners A and B and -0.98 for scanner C. With x-position, mAs changes were 4.9% or less. As the phantom moved into the y-positions, compared with the iso-center, the mAs varied by up to +70%, -34%, and +56% in scanners A, B, and C, respectively. For scanners A and B, noise in two regions of interest in the lower part of the phantom decreased with elevation, with correlation factors from -0.95 to -0.86 (P<0.02). In the x-direction, significant noise relationships (P<0.005) were only seen in scanner A. This study demonstrates that patient centering markedly affects the efficacy of AEC function and that tube current changes vary between scanners. Tube position when acquiring the scout projection radiograph is decisive for the direction of the mAs change. Off-center patient positions cause errors in tube current modulation that can outweigh the dose reduction gained by AEC use, and image quality is affected.

  14. Novel variant in the TP63 gene associated to ankyloblepharon-ectodermal dysplasia-cleft lip/palate (AEC) syndrome.

    PubMed

    Gonzalez, Francisco; Loidi, Lourdes; Abalo-Lojo, Jose M

    2017-01-01

    Ankyloblepharon-ectodermal dysplasia-cleft lip/palate (AEC) syndrome is a disorder resulting from anomalous embryonic development of ectodermal tissues. There is evidence that AEC syndrome is caused by mutations in the TP63 gene, which encodes the p63 protein. This is an important regulatory protein involved in epidermal proliferation and differentiation. Genome sequencing was performed in DNA from peripheral blood leukocytes of a newborn with AEC syndrome and her parents. Variants were searched in all coding exons and intron-exon boundaries of the TP63 gene. A heterozygous missense variant (NM_003722.4:c.1063G>C (p.Asp355His) was found in the newborn patient. No variants were found in either of the parents. We identified a previously unreported variant in TP63 gene which seems to be involved in the somatic malformations found in the AEC syndrome. The absence of this variant in both parents suggests that the variant appeared de novo.

  15. Human amniotic epithelial cell feeder layers maintain mouse embryonic stem cell pluripotency via epigenetic regulation of the c-Myc promoter.

    PubMed

    Liu, Te; Cheng, Weiwei; Liu, Tianjin; Guo, Lihe; Huang, Qin; Jiang, Lizhen; Du, Xiling; Xu, Fuhui; Liu, Zhixue; Lai, Dongmei

    2010-02-01

    Mouse embryonic stem cells (ESCs) are typically cultured on a feeder layer of mouse embryonic fibroblasts (MEFs), with leukemia inhibitory factor (LIF) added to maintain them in an undifferentiated state. We have previously shown that human amniotic epithelial cells (hAECs) can be used as feeder cells to maintain mouse ESC pluripotency, but the mechanism for this is unknown. In the present study, we found that CpG islands 5' of the c-Myc gene remain hypomethylated in mouse ESCs cultured on hAECs. In addition, levels of acetylation of histone H3 and trimethylation of histone H3K4 in the c-Myc gene promoter were higher in ES cells cultured on hAECs than those in ES cells cultured on MEFs. These data suggested that hAECs can alter mouse ESC gene expression via epigenetic modification of c-Myc, providing a possible mechanism for the hAEC-induced maintenance of ESCs in an undifferentiated state.

  16. COUPLING

    DOEpatents

    Hawke, B.C.

    1963-02-26

    This patent relates to a releasable coupling connecting a control rod to a control rod drive. This remotely operable coupling mechanism can connect two elements which are laterally and angviarly misaligned, and provides a means for sensing the locked condition of the elements. The coupling utilizes a spherical bayonet joint which is locked against rotation by a ball detent lock. (AEC)

  17. MAGNETIC END CLOSURES FOR PLASMA CONFINING AND HEATING DEVICES

    DOEpatents

    Post, R.F.

    1963-08-20

    More effective magnetic closure field regions for various open-ended containment magnetic fields used in fusion reactor devices are provided by several spaced, coaxially-aligned solenoids utilized to produce a series of nodal field regions of uniform or, preferably, of incrementally increasing intensity separated by lower intensity regions outwardly from the ends of said containment zone. Plasma sources may also be provided to inject plasma into said lower intensity areas to increase plasma density therein. Plasma may then be transported, by plasma diffusion mechanisms provided by the nodal fields, into the containment field. With correlated plasma densities and nodal field spacings approximating the mean free partl cle collision path length in the zones between the nodal fields, optimum closure effectiveness is obtained. (AEC)

  18. Conference Report: International Research Symposium on Ankyloblepharon-Ectodermal Defects-Cleft Lip and/or Palate (AEC) Syndrome

    PubMed Central

    Fete, Mary; vanBokhoven, Hans; Clements, Suzanne; McKeon, Frank; Roop, Dennis R.; Koster, Maranke I.; Missero, Caterina; Attardi, Laura D.; Lombillo, Vivian A.; Ratovitski, Edward; Julapalli, Meena; Ruths, Derek; Sybert, Virginia P.; Siegfried, Elaine C.; Bree, Alanna F.

    2009-01-01

    Ankyloblepharon-Ectodermal Defects-Cleft Lip/Palate (AEC) Syndrome (Hay-Wells syndrome, MIM #106220) is a rare autosomal dominant ectodermal dysplasia syndrome. It is due to mutations in the p63 gene, known to be a regulatory gene with many downstream gene targets. TP63 is important in the differentiation and proliferation of the epidermis, as well as many other processes including limb and facial development. It is also known that mutations in p63 lead to skin erosions. These erosions, especially on the scalp, are defining features of AEC syndrome and cause significant morbidity and mortality in these patients. It was this fact that led to the 2003 AEC Skin Erosion Workshop. That conference laid the groundwork for the International Research Symposium for AEC Syndrome held at Texas Children's Hospital in 2006. The conference brought together the largest cohort of individuals with AEC syndrome, along with a multitude of physicians and scientists. The overarching goals were to define the clinical and pathologic findings for improved diagnostic criteria, to obtain tissue samples for further study and to define future research directions. The symposium was successful in accomplishing these aims as detailed in this conference report. Following our report, we also present eleven manuscripts within this special section that outline the collective clinical, pathologic and mutational data from eighteen individuals enrolled in the concurrent Baylor College of Medicine IRB-approved protocol: Characterization of AEC syndrome. These collaborative findings will hopefully provide a stepping stone to future translational projects of p63 and p63-related syndromes. PMID:19353643

  19. Alveolar epithelial cell processing of nanoparticles activates autophagy and lysosomal exocytosis.

    PubMed

    Sipos, Arnold; Kim, Kwang-Jin; Chow, Robert H; Flodby, Per; Borok, Zea; Crandall, Edward D

    2018-05-03

    Utilizing confocal microscopy, we quantitatively assessed uptake, processing and egress of near infrared (NIR)-labeled carboxylated polystyrene nanoparticles (PNP) in live alveolar epithelial cells (AEC) during interactions with primary rat AEC monolayers (RAECM). PNP fluorescence intensity (content) and colocalization with intracellular vesicles in a cell were determined over the entire cell volume via z-stacking. Isotropic cuvette-based microfluorimetry was used to determine PNP concentration ([PNP]) from anisotropic measurements of PNP content assessed by confocal microscopy. Results showed that PNP uptake kinetics and steady state intracellular content decreased as diameter increased from 20 to 200 nm. For 20 nm PNP, uptake rate and steady state intracellular content increased with increased apical [PNP], but were unaffected by inhibition of endocytic pathways. Intracellular PNP increasingly co-localized with autophagosomes and/or lysosomes over time. PNP egress exhibited fast [Ca2+]-dependent release and a slower diffusion-like process. Inhibition of microtubule polymerization curtailed rapid PNP egress, resulting in elevated vesicular and intracellular PNP content. Interference with autophagosome formation led to slower PNP uptake and markedly decreased steady state intracellular content. At steady state, cytosolic [PNP] was higher than apical [PNP] and vesicular [PNP] (~80% of intracellular PNP content) exceeded both cytosolic [PNP] and intracellular [PNP]. These data are consistent with the hypotheses that (1) autophagic processing of nanoparticles is essential for maintenance of AEC integrity, (2) altered autophagy and/or lysosomal exocytosis may lead to AEC injury and (3) intracellular [PNP] in AEC is regulable, suggesting strategies for enhancement of nanoparticle-driven AEC gene/drug delivery and/or amelioration of AEC nanoparticle-related cellular toxicity.

  20. Involvement of Alveolar Epithelial Cell Necroptosis in IPF Pathogenesis.

    PubMed

    Lee, Ji-Min; Yoshida, Masahiro; Kim, Mi-So; Lee, June-Hyuk; Baek, Ae-Rin; Jang, An Soo; Kim, Do Jin; Minagawa, Shunsuke; Chin, Su Sie; Park, Choon-Sik; Araya, Jun; Kuwano, Kazuyoshi; Park, Sung Woo

    2018-02-14

    Alveolar epithelial cell (AEC) injury leading to cell death is involved in the process of fibrosis development during idiopathic pulmonary fibrosis (IPF). Among regulated/programmed cell death, the excessive apoptosis of AECs has been widely implicated in IPF pathogenesis. Necroptosis is a type of regulated/programmed necrosis. A multiprotein complex composed of receptor-interacting protein kinase-1 and -3 (RIPK1/3) plays a key regulatory role in initiating necroptosis. Although necroptosis participates in disease pathogeneses through the release of damage-associated molecular patterns (DAMPs), its association with IPF progression remains elusive. In this study, we attempted to illuminate the involvement of RIPK3-regulated necroptosis in IPF pathogenesis. IPF lung tissues were used to detect necroptosis, and the role of RIPK3 was determined using cell culturing models of AECs. Lung fibrosis models of bleomycin (BLM) treatment were also used. RIPK3 expression levels were increased in IPF lungs and both apoptosis and necroptosis were detected mainly in AECs. Necrostatin-1 and RIPK3 knockdown experiments in AECs revealed the participation of necroptosis in BLM and hydrogen peroxide-induced cell death. BLM treatment induced RIPK3 expression in AECs and increased High Mobility Group Box 1 (HMGB1) and interleukin 1β (IL-1β) levels in mouse lungs. The efficient attenuation of BLM-induced lung inflammation and fibrosis was determined in RIPK3 knockout mice and by necrostatin-1 with a concomitant reduction in HMGB1 and IL-1β. RIPK3-regulated necroptosis in AECs is involved in the mechanism of lung fibrosis development through the release of DAMPs as part of the pathogenic sequence of IPF.

  1. APPARATUS FOR ELECTRON BEAM HEATING CONTROL

    DOEpatents

    Jones, W.H.; Reece, J.B.

    1962-09-18

    An improved electron beam welding or melting apparatus is designed which utilizes a high voltage rectifier operating below its temperature saturation region to decrease variations in electron beam current which normally result from the gas generated in such apparatus. (AEC)

  2. Transversal inducing differentiation of human amniotic epithelial cells into hepatocyte-like cells.

    PubMed

    Luo, Hongwu; Huang, Xiangjun; Huang, Feizhou; Liu, Xunyang

    2011-06-01

    To evaluate the in vitro differentiation of human amniotic epithelial cells (hAECs ) into hepatocyte-like cells. Combined approach of dexamethasone, HGF, IGF and other cytokines were used to induce the differentiation of hAECs into hepatocyte-like cells. The induction lasted 2 weeks. During the induction, the expression of albumin ALB, CYP1A1, CYP1A2, IGFR, c-met and key functional genes related to liver cells as well as transcription factors HNF3, HNF4 and C/EBPa were monitored by RT-PCR. Time dependent changes of the surface marker colony ALB, AFP and CK18 were analyzed by cell flow cytometry. After the 2 week induction, the expressions of liver hepatocyte-like cell functional genes such as albumin, CYP1A1, CYP1A2, c-met, and transcription factors such as HNF3, HNF4, C/EBPa and HNF1 were observed. Six days after the induction, hAECs mainly were stained AFP+, and the positive rate was (15.1 ± 2.1)%. While 10 days after the induction, part of the hAECs showed AFP+/ALB+ (6.5 ± 1.4)%; and on 14th day, hAECs only showed ALB+, and the rate was (13.9 ± 2.3)%. ALB+ cell increase indicated a gradual functional maturation from the hAECs to hepatocyte-like cells. Similaritly, the number of CK18+ cells in the whole population was also increased: On 10th day, the rate was (16.1 ± 1.2)%; on 14th day, that was (21.3 ± 4.6)%, which proved the above hypothesis of the trandifferentiation. By extending the induction time, the expression of functional genes increased gradually, and a maturing process of hAECs was detected by cell surface markers. The differentiation of hAECs induced in vitro has the characteristics of hepatocyte-like cells.

  3. CONTROL ROD DRIVE MECHANISM FOR A NUCLEAR REACTOR

    DOEpatents

    Hawke, B.C.; Liederbach, F.J.; Lones, W.

    1963-05-14

    A lead-screw-type control rod drive featuring an electric motor and a fluid motor arranged to provide a selectably alternative driving means is described. The electric motor serves to drive the control rod slowly during normal operation, while the fluid motor, assisted by an automatic declutching of the electric motor, affords high-speed rod insertion during a scram. (AEC)

  4. A cleanser based on sodium laureth carboxylate and alkyl carboxylates washes facial sebum well but does not induce dry skin.

    PubMed

    Yokoi, Aya; Endo, Koji; Ozawa, Toshiaki; Miyaki, Masahiro; Matsuo, Keiko; Nozawa, Kazumi; Manabe, Motomu; Takagi, Yutaka

    2014-12-01

    Because excess sebum and/or metabolites of sebum induce skin problems, cleansers that can remove those kinds of sebum are sought after. However, many people, especially who have little facial sebum, are afraid to wash off sebum well because that may induce dry skin. This concern may be caused by the result that cleansers with a high cleansing ability tend to decrease not only facial sebum but also natural moisturizing factors and intercellular lipids that are essential for cutaneous function. Recently, we have developed a new cleanser based on sodium laureth carboxylate and alkyl carboxylates (AEC/soap) that cleans sebum well without penetrating the stratum corneum. This trial was aim to clarify the effects of sebum removal by AEC/soap-based cleanser on the induction of dry skin. We designed a controlled single blind parallel trial. Thirty female subjects with mild dry skin were assigned randomly to two groups: one group used AEC/soap-based cleanser while the other group kept using their usual facial cleanser twice a day for 4 weeks in the winter season. Using a colored artificial sebum mixture, it was demonstrated that this cleanser washed sebum well. Following usage of this cleanser, their dry skin improved rather than worsen which was indicated by instrumental analysis and visual assessment. These improvements were recognized by subjects. These results suggest that AEC/soap-based cleanser washes off facial sebum well, but it has little effect on the induction of dry skin because of less penetration into stratum corneum. © 2014 Wiley Periodicals, Inc.

  5. Pathologic changes of wound tissue in rats with stage III pressure ulcers treated by transplantation of human amniotic epithelial cells.

    PubMed

    Zheng, Xilan; Jiang, Zhixia; Zhou, Aiting; Yu, Limei; Quan, Mingtao; Cheng, Huagang

    2015-01-01

    This study aims to determine the impact of orthotopic transplantation of human amniotic epithelial cells (hAECs) on the pathologic changes of wound tissues in a self-prepared rat stage III pressure ulcer model. Ninety-six SD rats were randomly divided into the model group (group M), hAEC transplantation group (group H), traditional treatment group (group T), and the control group (group C), with 24 rats in each group. The wound healing time was observed in 6 rats from each group, and 6 rats of each group were selected for post-modeling on day(s) (D) 1, 3, and 7 for HE staining to compare the pathological changes. The healing time of group H was significantly shorter than the other three groups. Moreover, pathological observations revealed that group H exhibited significant proliferation of fibrous tissues and vessels in the dermal layer, and the appearance time and degree of skin appendages were significantly greater than that observed in the other three groups. Pathological observations showed that hAEC transplantation could significantly speed up the healing of stage III pressure ulcer.

  6. Nuclear Fuel Reprocessing: U.S. Policy Development

    DTIC Science & Technology

    2006-11-29

    to the chemical separation of fissionable uranium and plutonium from irradiated nuclear fuel. The World War II-era Manhattan Project developed...created the Atomic Energy Commission (AEC) and transferred production and control of fissionable materials from the Manhattan Project . As the exclusive

  7. Investigation of microgravity effects on basic imune functions on the cellular level - The TRIPLELUX-B experiment

    NASA Astrophysics Data System (ADS)

    Unruh, Eckehardt; Hansen, Peter-Diedrich

    Hemocytes are the primary defence of the Blue Mussel against invading microorganisms and foreign particles. The hemocytes of mussels as part of the immune system of invertebrates has not been studied so far in space. The choice of the phagocytes from invertebrates is justified by the claim to study the universal validity of innate immune responses. The hemocytes of mussels have a lot in common with macrophages of higher organisms. They are able to detect the presence of microorganisms and kill these microorganisms by phagocytosis. The phagocy-tosis related production of ROS will be stimulated with opsonised zymosan. The hemocytes will be stored frozen and reconstituted in-flight for the experiment. The signals of the im-muno cellular responses are translated into luminescence as a rapid optical reporter system. The primary aim of Triplelux B is to investigate under space flight conditions the effect of microgravity on the ability of isolated Blue Mussel hemocytes to perform phagocytosis. As a secondery objectiv, the results expected will allow to conclude whether the observed responses are caused by microgravity and/or radiation (change in permeability, endpoints in genotoxicity: DNA unwinding). The TRIPLELUX-B Experiment contributes to risk assessment concerning immunotoxicity under space flight conditions. The components of the fully automated AEC (Advanced Experimental Containment) will be demonstrated. The AEC of the TRIPLELUX-B experiment will contribute to a real time operational monitoring for immunotoxicity testing for earth. Blue mussels have been used repeatedly for monitoring imunotoxicity and genotoxicity in coastal waters. Based on the AEC an automatet measuring device will allow "real time monitoring" providing observations of immunotoxicity in coastal and inland waters.

  8. Risk of high-grade cervical dysplasia and gynaecological malignancies following the cytologic diagnosis of atypical endocervical cells of undetermined significance: a retrospective study of a state-wide screening population in Western Australia.

    PubMed

    Munro, Aime; Williams, Vincent; Semmens, James; Leung, Yee; Stewart, Colin J R; Codde, Jim; Spilsbury, Katrina; Steel, Nerida; Cohen, Paul; O'leary, Peter

    2015-06-01

    In 2006, Australia adopted a revised cervical cytology terminology system, known as the Australian Modified Bethesda System (AMBS). One substantial change in the AMBS was the introduction of the diagnostic category of atypical endocervical cells (AEC) of undetermined significance. The aim of this study was to investigate the incidence of histologically confirmed high-grade cervical dysplasia (cervical intra-epithelial neoplasia (CIN) grades 2 and 3 and adenocarcinoma in situ (ACIS)), cervical carcinoma and endometrial carcinoma in women presenting with AEC on cervical cytology. A seven-year retrospective study examining clinical outcomes of women with AEC on a screening cervical smear. Cytology and histology results were extracted from the Western Australia Cervical Screening Registry, and time-to-event analysis was used to predict the odds of having or developing in situ and invasive neoplasia. AEC was reported in index smears from 0.093% (584/622754) women during the study period. No follow-up was available in 35 AEC cases. Sixty-five of the remaining 549 women (11.8%) had, or developed, high-grade cervical dysplasia within five years of their index AEC diagnosis. Endometrial cancer was diagnosed in 21 women and cervical cancer in four women during the follow-up period. Cytologic demonstration of AEC requires careful gynaecologic evaluation, particularly in younger women who may be found to have either high-grade squamous (CIN) or glandular (ACIS) lesions, while in older women, the possibility of endometrial neoplasia needs to be considered. © 2015 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  9. Modeling AEC—New Approaches to Study Rare Genetic Disorders

    PubMed Central

    Koch, Peter J.; Dinella, Jason; Fete, Mary; Siegfried, Elaine C.; Koster, Maranke I.

    2015-01-01

    Ankyloblepharon-ectodermal defects-cleft lip/palate (AEC) syndrome is a rare monogenetic disorder that is characterized by severe abnormalities in ectoderm-derived tissues, such as skin and its appendages. A major cause of morbidity among affected infants is severe and chronic skin erosions. Currently, supportive care is the only available treatment option for AEC patients. Mutations in TP63, a gene that encodes key regulators of epidermal development, are the genetic cause of AEC. However, it is currently not clear how mutations in TP63 lead to the various defects seen in the patients’ skin. In this review, we will discuss current knowledge of the AEC disease mechanism obtained by studying patient tissue and genetically engineered mouse models designed to mimic aspects of the disorder. We will then focus on new approaches to model AEC, including the use of patient cells and stem cell technology to replicate the disease in a human tissue culture model. The latter approach will advance our understanding of the disease and will allow for the development of new in vitro systems to identify drugs for the treatment of skin erosions in AEC patients. Further, the use of stem cell technology, in particular induced pluripotent stem cells (iPSC), will enable researchers to develop new therapeutic approaches to treat the disease using the patient’s own cells (autologous keratinocyte transplantation) after correction of the disease-causing mutations. PMID:24665072

  10. Immunological compatibility status of placenta-derived stem cells is mediated by scaffold 3D structure.

    PubMed

    Azizian, Sara; Khatami, Fatemeh; Modaresifar, Khashayar; Mosaffa, Nariman; Peirovi, Habibollah; Tayebi, Lobat; Bahrami, Soheyl; Redl, Heinz; Niknejad, Hassan

    2018-02-23

    Placenta-derived amniotic epithelial cells (AECs), a great cell source for tissue engineering and stem cell therapy, are immunologically inert in their native state; however, immunological changes in these cells after culture and differentiation have challenged their applications. The aim of this study was to investigate the effect of 2D and 3D scaffolds on human lymphocyte antigens (HLA) expression by AECs. The effect of different preparation parameters including pre-freezing time and temperature was evaluated on 3D chitosan-gelatine scaffolds properties. Evaluation of MHC class I, HLA-DR and HLA-G expression in AECs after 7 d culture on 2D bed and 3D scaffold of chitosan-gelatine showed that culture of AECs on the 2D substrate up-regulated MHC class I and HLA-DR protein markers on AECs surface and down-regulated HLA-G protein. In contrast, 3D scaffold did not increase protein expression of MHC class I and HLA-DR. Moreover, HLA-G protein expression remained unchanged in 3D culture. These results confirm that 3D scaffold can remain AECs in their native immunological state and modification of physical properties of the scaffold is a key regulator of immunological markers at the gene and protein expression levels; a strategy which circumvents rejection challenge of amniotic stem cells to be translated into the clinic.

  11. Genotoxic and biochemical changes in Baccharis trimera induced by coal contamination.

    PubMed

    Menezes, A P S; Da Silva, J; Rossato, R R; Santos, M S; Decker, N; Da Silva, F R; Cruz, C; Dihl, R R; Lehmann, M; Ferraz, A B F

    2015-04-01

    The processing and combustion of coal in thermal power plants release anthropogenic chemicals into the environment. Baccharis trimera is a common plant used in folk medicine that grows readily in soils degraded by coal mining activities. This shrub bioaccumulates metals released into the environment, and thus its consumption may be harmful to health. The purpose of this study was to investigate the phytochemical profile, antioxidant capacity (DPPH), genotoxic (comet assay) and mutagenic potential (CBMN-cyt) in V79 cells of B. trimera aqueous extracts in the coal-mining region of Candiota (Bt-AEC), and in Bagé, a city that does not experience the effects of exposure to coal (Bt-AEB, a reference site). In the comet assay, only Bt-AEC was genotoxic at the highest doses (0.8mg/mL and 1.6mg/mL), compared to the control. For extracts from both areas, mutagenic effects were observed at higher concentrations compared to the control. The cell damage parameters were significantly high in both extracts; however, more striking values were observed for Bt-AEC, up to the dose of 0.8mg/mL. In chemical analysis, no variation was observed in the contents of flavonoids and phenolic compounds, neither the antioxidant activity, which may suggest that DNA damage observed in V79 cells was induced by the presence of coal contaminants absorbed by the plant. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. A/E/C CAD Standard, Release 5.0

    DTIC Science & Technology

    2012-12-01

    System Control Panels Halon System Inert Gas Smoke/Pressurization Control Egress Requirements Fire Protection System Appendix A ... System Natural Gas System Miter Gates Makeup Air System Appendix A Model File Level/Layer Assignment Tables A54 Discipline: Mechanical Model...SWITCHES Element type: Symbol Electrical: STP14B SURFACE 1X4 STRIP BATTERY Element type: Symbol Electrical: SUBST A

  13. NUCLEAR REACTOR FUEL ELEMENT

    DOEpatents

    Currier, E.L. Jr.; Nicklas, J.H.

    1963-06-11

    A fuel plate is designed for incorporation into control rods of the type utilized in high-flux test reactors. The fuel plate is designed so that the portion nearest the poison section of the control rod contains about one-half as much fissionable material as in the rest of the plate, thereby eliminating dangerous flux peaking in that portion. (AEC)

  14. Digital Astronaut Project Biomechanical Models: Biomechanical Modeling of Squat, Single-Leg Squat and Heel Raise Exercises on the Hybrid Ultimate Lifting Kit (HULK)

    NASA Technical Reports Server (NTRS)

    Thompson, William K.; Gallo, Christopher A.; Crentsil, Lawton; Lewandowski, Beth E.; Humphreys, Brad T.; DeWitt, John K.; Fincke, Renita S.; Mulugeta, Lealem

    2015-01-01

    The NASA Digital Astronaut Project (DAP) implements well-vetted computational models to predict and assess spaceflight health and performance risks, and to enhance countermeasure development. The DAP Musculoskeletal Modeling effort is developing computational models to inform exercise countermeasure development and to predict physical performance capabilities after a length of time in space. For example, integrated exercise device-biomechanical models can determine localized loading, which will be used as input to muscle and bone adaptation models to estimate the effectiveness of the exercise countermeasure. In addition, simulations of mission tasks can be used to estimate the astronaut's ability to perform the task after exposure to microgravity and after using various exercise countermeasures. The software package OpenSim (Stanford University, Palo Alto, CA) (Ref. 1) is being used to create the DAP biomechanical models and its built-in muscle model is the starting point for the DAP muscle model. During Exploration missions, such as those to asteroids and Mars, astronauts will be exposed to reduced gravity for extended periods. Therefore, the crew must have access to exercise countermeasures that can maintain their musculoskeletal and aerobic health. Exploration vehicles may have very limited volume and power available to accommodate such capabilities, even more so than the International Space Station (ISS). The exercise devices flown on Exploration missions must be designed to provide sufficient load during the performance of various resistance and aerobic/anaerobic exercises while meeting potential additional requirements of limited mass, volume and power. Given that it is not practical to manufacture and test (ground, analog and/or flight) all candidate devices, nor is it always possible to obtain data such as localized muscle and bone loading empirically, computational modeling can estimate the localized loading during various exercise modalities performed on a given device to help formulate exercise prescriptions and other operational considerations. With this in mind, NASA's Digital Astronaut Project (DAP) is supporting the Advanced Exercise Concepts (AEC) Project, Exercise Physiology and Countermeasures (ExPC) laboratory and NSBRI-funded researchers by developing and implementing well-validated computational models of exercises with advanced exercise device concepts. This report focuses specifically on lower-body resistance exercises performed with the Hybrid Ultimate Lifting Kit (HULK) device as a deliverable to the AEC Project.

  15. A high voltage power supply for the AE-C and D low energy electron experiment

    NASA Technical Reports Server (NTRS)

    Gillis, J. A.

    1974-01-01

    A description is given of the electrical and mechanical design and operation of high voltage power supplies for space flight use. The supply was used to generate the spiraltron high voltage for low energy electron experiment on AE-C and D. Two versions of the supply were designed and built; one design is referred to as the low power version (AE-C) and the other as the high power version (AE-D). Performance is discussed under all operating conditions.

  16. Automatic exposure control at single- and dual-heartbeat CTCA on a 320-MDCT volume scanner: effect of heart rate, exposure phase window setting, and reconstruction algorithm.

    PubMed

    Funama, Yoshinori; Utsunomiya, Daisuke; Taguchi, Katsuyuki; Oda, Seitaro; Shimonobo, Toshiaki; Yamashita, Yasuyuki

    2014-05-01

    To investigate whether electrocardiogram (ECG)-gated single- and dual-heartbeat computed tomography coronary angiography (CTCA) with automatic exposure control (AEC) yields images with uniform image noise at reduced radiation doses. Using an anthropomorphic chest CT phantom we performed prospectively ECG-gated single- and dual-heartbeat CTCA on a second-generation 320-multidetector CT volume scanner. The exposure phase window was set at 75%, 70-80%, 40-80%, and 0-100% and the heart rate at 60 or 80 or corr80 bpm; images were reconstructed with filtered back projection (FBP) or iterative reconstruction (IR, adaptive iterative dose reduction 3D). We applied AEC and set the image noise level to 20 or 25 HU. For each technique we determined the image noise and the radiation dose to the phantom center. With half-scan reconstruction at 60 bpm, a 70-80% phase window- and a 20-HU standard deviation (SD) setting, the imagenoise level and -variation along the z axis manifested similar curves with FBP and IR. With half-scan reconstruction, the radiation dose to the phantom center with 70-80% phase window was 18.89 and 12.34 mGy for FBP and 4.61 and 3.10 mGy for IR at an SD setting SD of 20 and 25 HU, respectively. At 80 bpm with two-segment reconstruction the dose was approximately twice that of 60 bpm at both SD settings. However, increasing radiation dose at corr80 bpm was suppressed to 1.39 times compared to 60 bpm. AEC at ECG-gated single- and dual-heartbeat CTCA controls the image noise at different radiation dose. Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  17. Quantitative Analysis of Proteome Modulations in Alveolar Epithelial Type II Cells in Response to Pulmonary Aspergillus fumigatus Infection.

    PubMed

    Seddigh, Pegah; Bracht, Thilo; Molinier-Frenkel, Válerie; Castellano, Flavia; Kniemeyer, Olaf; Schuster, Marc; Weski, Juliane; Hasenberg, Anja; Kraus, Andreas; Poschet, Gernot; Hager, Thomas; Theegarten, Dirk; Opitz, Christiane A; Brakhage, Axel A; Sitek, Barbara; Hasenberg, Mike; Gunzer, Matthias

    2017-12-01

    The ubiquitous mold Aspergillus fumigatus threatens immunosuppressed patients as inducer of lethal invasive aspergillosis. A. fumigatus conidia are airborne and reach the alveoli, where they encounter alveolar epithelial cells (AEC). Previous studies reported the importance of the surfactant-producing AEC II during A. fumigatus infection via in vitro experiments using cell lines. We established a negative isolation protocol yielding untouched primary murine AEC II with a purity >90%, allowing ex vivo analyses of the cells, which encountered the mold in vivo By label-free proteome analysis of AEC II isolated from mice 24h after A. fumigatus or mock infection we quantified 2256 proteins and found 154 proteins to be significantly differentially abundant between both groups (ANOVA p value ≤ 0.01, ratio of means ≥1.5 or ≤0.67, quantified with ≥2 peptides). Most of these proteins were higher abundant in the infected condition and reflected a comprehensive activation of AEC II on interaction with A. fumigatus This was especially represented by proteins related to oxidative phosphorylation, hence energy production. However, the most strongly induced protein was the l-amino acid oxidase (LAAO) Interleukin 4 induced 1 (IL4I1) with a 42.9 fold higher abundance (ANOVA p value 2.91 -10 ). IL4I1 has previously been found in B cells, macrophages, dendritic cells and rare neurons. Increased IL4I1 abundance in AEC II was confirmed by qPCR, Western blot and immunohistology. Furthermore, A. fumigatus infected lungs showed high levels of IL4I1 metabolic products. Importantly, higher IL4I1 abundance was also confirmed in lung tissue from human aspergilloma. Because LAAO are key enzymes for bactericidal product generation, AEC II might actively participate in pathogen defense. We provide insights into proteome changes of primary AEC II thereby opening new avenues to analyze the molecular changes of this central lung cell on infectious threats. Data are available via ProteomeXchange with identifier PXD005834. © 2017 by The American Society for Biochemistry and Molecular Biology, Inc.

  18. Reduced transforming growth factor β1 (TGF-β1) in the repair of airway epithelial cells of children with asthma.

    PubMed

    Ling, Kak-Ming; Sutanto, Erika N; Iosifidis, Thomas; Kicic-Starcevich, Elizabeth; Looi, Kevin; Garratt, Luke W; Martinovich, Kelly M; Lannigan, Francis J; Knight, Darryl A; Stick, Stephen M; Kicic, Anthony

    2016-10-01

    Evidence into the role of TGF-β1 in airway epithelial repair in asthma is still controversial. This study tested the hypothesis that the reduced TGF-β1 levels previously observed in paediatric asthmatic airway epithelial cells directly contribute to the dysregulated repair seen in these cells. Primary airway epithelial cells (pAEC) from children with asthma (n = 16) and non-asthmatic subjects (n = 20) were isolated, and subcultured for investigation of TGF-β1 gene and protein via quantitative polymerase chain reaction (qPCR) and enzyme-linked immunosorbent assay (ELISA), respectively. Expression of other associated genes such as integrins αvβ6, αvβ8 and MT1-MMP were also tested. Small interfering RNA (siRNA) was employed to assess the role of TGF-β1 during wound repair. TGF-β1 gene and protein expression were significantly downregulated in asthmatic pAEC over the course of repair, compared with cells from non-asthmatic children. Messenger RNA (mRNA) expression of TGF-β1 was also directly implicated in non-asthmatic and asthmatic pAEC proliferation over their quiescent counterparts. Small interfering RNA-mediated knockdown of TGF-β1 compromised repair in non-asthmatic pAEC and exacerbated the dysregulated repair seen in asthmatic pAEC. Expression of major TGF-β1 activators of epithelial cells, integrin αvβ6 and αvβ8 was also measured and there was no difference in αvβ6 gene expression between the two cohorts. Although integrin αvβ8 gene expression was significantly higher in asthmatic pAEC, the expression of MT1-MMP (MMP14) which facilitates the αvβ8 mediated TGF-β1 activation was significantly downregulated. Our data has highlighted the importance of TGF-β1 in pAEC wound repair in vitro. The significantly lower levels seen in asthmatic pAEC subsequently contributes to the dysregulated repair observed in these cells. © 2016 Asian Pacific Society of Respirology.

  19. SU-G-IeP3-02: Characteristics of In-Vivo MOSFET Dosimeters for Diagnostic X-Ray Low-Dose Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, S; Ali, S; Harper, K

    Purpose: To correct in-vivo metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters dependence on X-ray energy, dose and dose rate, and temperature in order to measure doses or exposures on several anatomic points of interest undergoing some routine radiographs. Methods: A mobile MOSFET system (BEST Medical) was carefully calibrated with X-ray at kVp of 70, 80, 100, 120, and 138 kVp, phantom temperatures at 0, 21, and 43 oC, and exposure range from 0.01 to 10 R confirmed with Raysafe and RadCal dosimeters. The MOSFETS were placed on the midline bladder or uterus, left pelvic iliac artery, left abdominal above iliac crest, abdominalmore » midline anterior at inferior margin of stomach, and left pectoral of a large and a small body-size cadavers undergoing AP/PA chest and lumber spine radiographs using manual and automatic exposure control (AEC) with and without lead shielding. MOSTFETs and TLD chips were also placed on the stomach, sigmoid, pubic symphysis, left and right pelvic walls of another cadaver for AP pelvic manual or AEC radiography prior to and after a left hip metal implant. Results: Individual MOSFET detectors had various low-dose limits in ranged from 0.03 to 0.08 R, nonlinear response to X-ray energy, and significant temperature effect of 15%. By accumulating 10 manual exposures and 20 AEC exposures, we achieved dose measured accuracy of 6%. There were up to 8 fold increases for AEC exposure of spine and chest X-ray procedure from no shielding to with shielding. For pelvic radiography, exposure to public symphysis was the highest even higher than that of the skin. After hip implant, AEC pelvic radiograph increase exposure by 30 to 200% consistent with results of TLDs. Conclusion: Dependence of energy, temperature and dose limit were accurately corrected. We have found significant exposure for those clinical pr°ocedures and the study provided evidences for developing new clinical procedures.« less

  20. Mechanisms of transcriptional repression of cell-cycle G2/M promoters by p63

    PubMed Central

    Testoni, Barbara; Mantovani, Roberto

    2006-01-01

    p63 is a developmentally regulated transcription factor related to p53, which activates and represses specific genes. The human AEC (Ankyloblepharon–Ectodermal dysplasia-Clefting) and EEC (Ectrodactyly–Ectodermal dysplasia–Cleft lip/palate) syndromes are caused by missense mutations of p63, within the DNA-binding domain (EEC) or in the C-terminal sterile alpha motif domain (AEC). We show here that p63 represses transcription of cell-cycle G2/M genes by binding to multiple CCAAT core promoters in immortalized and primary keratinocytes. The CCAAT-activator NF-Y and ΔNp63α are associated in vivo and a conserved α-helix of the NF-YC histone fold is required. p63 AEC mutants, but not an EEC mutant, are incapable to bind NF-Y. ΔNp63α, but not the AEC mutants repress CCAAT-dependent transcription of G2/M genes. Chromatin immunoprecipitation recruitment assays establish that the AEC mutants are not recruited to G2/M promoters, while normally present on 14-3-3σ, which contains a sequence-specific binding site. Surprisingly, the EEC C306R mutant activates transcription. Upon keratinocytes differentiation, NF-Y and p63 remain bound to G2/M promoters, while HDACs are recruited, histones deacetylated, Pol II displaced and transcription repressed. Our data indicate that NF-Y is a molecular target of p63 and that inhibition of growth activating genes upon differentiation is compromised by AEC missense mutations. PMID:16473849

  1. Impact of compressed breast thickness and dose on lesion detectability in digital mammography: FROC study with simulated lesions in real mammograms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salvagnini, Elena, E-mail: elena.salvagnini@gmail.

    Purpose: The aim of this work was twofold: (1) to examine whether, with standard automatic exposure control (AEC) settings that maintain pixel values in the detector constant, lesion detectability in clinical images decreases as a function of breast thickness and (2) to verify whether a new AEC setup can increase lesion detectability at larger breast thicknesses. Methods: Screening patient images, acquired on two identical digital mammography systems, were collected over a period of 2 yr. Mammograms were acquired under standard AEC conditions (part 1) and subsequently with a new AEC setup (part 2), programmed to use the standard AEC settingsmore » for compressed breast thicknesses ≤49 mm, while a relative dose increase was applied above this thickness. The images were divided into four thickness groups: T1 ≤ 29 mm, T2 = 30–49 mm, T3 = 50–69 mm, and T4 ≥ 70 mm, with each thickness group containing 130 randomly selected craniocaudal lesion-free images. Two measures of density were obtained for every image: a BI-RADS score and a map of volumetric breast density created with a software application (VolparaDensity, Matakina, NZ). This information was used to select subsets of four images, containing one image from each thickness group, matched to a (global) BI-RADS score and containing a region with the same (local) VOLPARA volumetric density value. One selected lesion (a microcalcification cluster or a mass) was simulated into each of the four images. This process was repeated so that, for a given thickness group, half the images contained a single lesion and half were lesion-free. The lesion templates created and inserted in groups T3 and T4 for the first part of the study were then inserted into the images of thickness groups T3 and T4 acquired with higher dose settings. Finally, all images were visualized using the ViewDEX software and scored by four radiologists performing a free search study. A statistical jackknife-alternative free-response receiver operating characteristic analysis was applied. Results: For part 1, the alternative free-response receiver operating characteristic curves for the four readers were 0.80, 0.65, 0.55 and 0.56 in going from T1 to T4, indicating a decrease in detectability with increasing breast thickness. P-values and the 95% confidence interval showed no significant difference for the T3-T4 comparison (p = 0.78) while all the other differences were significant (p < 0.05). Separate analysis of microcalcification clusters presented the same results while for mass detection, the only significant difference came when comparing T1 to the other thickness groups. Comparing the scores of part 1 and part 2, results for the T3 group acquired with the new AEC setup and T3 group at standard AEC doses were significantly different (p = 0.0004), indicating improved detection. For this group a subanalysis for microcalcification detection gave the same results while no significant difference was found for mass detection. Conclusions: These data using clinical images confirm results found in simple QA tests for many mammography systems that detectability falls as breast thickness increases. Results obtained with the AEC setup for constant detectability above 49 mm showed an increase in lesion detection with compressed breast thickness, bringing detectability of lesions to the same level.« less

  2. APPARATUS FOR CONTROL OF A BOILING REACTOR RESPONSIVE TO STEAM DEMAND

    DOEpatents

    Treshow, M.

    1963-07-23

    A method of controlling a fuel-rod-in-tube-type boilingwater reactor having nozzles at the point of water entry into the tube is described. Water is pumped into the nozzles by an auxiliary pump operated by steam from an interstage position of the associated turbine, so that the pumping speed is responsive to turbine demand. (AEC)

  3. REACTOR

    DOEpatents

    Szilard, L.

    1963-09-10

    A breeder reactor is described, including a mass of fissionable material that is less than critical with respect to unmoderated neutrons and greater than critical with respect to neutrons of average energies substantially greater than thermal, a coolant selected from sodium or sodium--potassium alloys, a control liquid selected from lead or lead--bismuth alloys, and means for varying the quantity of control liquid in the reactor. (AEC)

  4. Exercise training regulates SOD-1 and oxidative stress in porcine aortic endothelium.

    PubMed

    Rush, James W E; Turk, James R; Laughlin, M Harold

    2003-04-01

    Vascular oxidative stress contributes to endothelial dysfunction. Aerobic exercise training improves vascular function. The purpose of this study was to test the hypothesis that exercise training would improve the balance of antioxidant to prooxidant enzymes and reduce markers of oxidative stress in aortic endothelial cells (AEC). Female Yucatan miniature pigs either remained sedentary (SED) or were exercise trained (EX) for 16-19 wk. EX pigs had increased AEC SOD-1 protein levels and Cu/Zn SOD activity of the whole aorta compared with SED pigs. Protein levels of other antioxidant enzymes (SOD-2, catalase) were not affected by exercise training. Protein levels of p67(phox), a subunit of the prooxidant enzyme NAD(P)H oxidase, were reduced in EX vs. SED AEC. These EX adaptations were associated with lower AEC malondialdehyde levels and decreased phosphorylation of ERK-1/2. Endothelial nitric oxide synthase protein, protein nitrotyrosine content, and heme oxygenase-1 protein were not different in EX vs. SED pigs. We conclude that chronic aerobic exercise training influenced both antioxidant and prooxidant enzymes and decreased indexes of oxidative stress in AEC. These adaptations may contribute to improved endothelial function with exercise training.

  5. Environmental friendly technology for aluminum electrolytic capacitors recycling from waste printed circuit boards.

    PubMed

    Wang, Jianbo; Xu, Zhenming

    2017-03-15

    up to now, the recycling of e-waste should be developed towards more depth and refinement to promote industrial production of e-waste resource recovery. in the present study, the recycling of aluminum electrolytic capacitors (AECs) from waste printed circuit boards (WPCBs) is focused on. First of all, AECs are disassembled from WPCBs by a self-designed machine; meanwhile, the disassembled AECs are subjected to an integrated process, involving heating treatment, crushing, sieving, and magnetic separating, to recover aluminum and iron; finally, the off-gas and residue generated during the aforementioned processes are analyzed to evaluate environmental risks. The results indicate that 96.52% and 98.68% of aluminum and iron, respectively, can be recovered from AECs under the optimal condition. The off-gas generated during the process is mainly composed of elements of C, H, and O, indicating that the off-gas is non-toxic and could be re-utilized as clean energy source. The residue according with toxicity characteristics leaching standard can be landfilled safely in sanitary landfill site. The present study provides an environmentally friendly and industrial application potential strategy to recycle AECs to promote e-waste recycling industry. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Interactions of Aspergillus fumigatus Conidia with Airway Epithelial Cells: A Critical Review

    PubMed Central

    Croft, Carys A.; Culibrk, Luka; Moore, Margo M.; Tebbutt, Scott J.

    2016-01-01

    Aspergillus fumigatus is an environmental filamentous fungus that also acts as an opportunistic pathogen able to cause a variety of symptoms, from an allergic response to a life-threatening disseminated fungal infection. The infectious agents are inhaled conidia whose first point of contact is most likely to be an airway epithelial cell (AEC). The interaction between epithelial cells and conidia is multifaceted and complex, and has implications for later steps in pathogenesis. Increasing evidence has demonstrated a key role for the airway epithelium in the response to respiratory pathogens, particularly at early stages of infection; therefore, elucidating the early stages of interaction of conidia with AECs is essential to understand the establishment of infection in cohorts of at-risk patients. Here, we present a comprehensive review of the early interactions between A. fumigatus and AECs, including bronchial and alveolar epithelial cells. We describe mechanisms of adhesion, internalization of conidia by AECs, the immune response of AECs, as well as the role of fungal virulence factors, and patterns of fungal gene expression characteristic of early infection. A clear understanding of the mechanisms involved in the early establishment of infection by A. fumigatus could point to novel targets for therapy and prophylaxis. PMID:27092126

  7. Effect of Beetroot Juice Supplementation on Aerobic Response during Swimming

    PubMed Central

    Pinna, Marco; Roberto, Silvana; Milia, Raffaele; Marongiu, Elisabetta; Olla, Sergio; Loi, Andrea; Migliaccio, Gian Mario; Padulo, Johnny; Orlandi, Carmine; Tocco, Filippo; Concu, Alberto; Crisafulli, Antonio

    2014-01-01

    The beneficial effects of beetroot juice supplementation (BJS) have been tested during cycling, walking, and running. The purpose of the present study was to investigate whether BJS can also improve performance in swimmers. Fourteen moderately trained male master swimmers were recruited and underwent two incremental swimming tests randomly assigned in a pool during which workload, oxygen uptake (VO2), carbon dioxide production (VCO2), pulmonary ventilation (VE), and aerobic energy cost (AEC) of swimming were measured. One was a control swimming test (CSW) and the other a swimming test after six days of BJS (0.5l/day organic beetroot juice containing about 5.5 mmol of NO3−). Results show that workload at anaerobic threshold was significantly increased by BJS as compared to the CSW test (6.3 ± 1 and 6.7 ± 1.1 kg during the CSW and the BJS test respectively). Moreover, AEC was significantly reduced during the BJS test (1.9 ± 0.5 during the SW test vs. 1.7 ± 0.3 kcal·kg−1·h−1 during the BJS test). The other variables lacked a statistically significant effect with BJS. The present investigation provides evidence that BJS positively affects performance of swimmers as it reduces the AEC and increases the workload at anaerobic threshold. PMID:24481133

  8. Effect of beetroot juice supplementation on aerobic response during swimming.

    PubMed

    Pinna, Marco; Roberto, Silvana; Milia, Raffaele; Marongiu, Elisabetta; Olla, Sergio; Loi, Andrea; Migliaccio, Gian Mario; Padulo, Johnny; Orlandi, Carmine; Tocco, Filippo; Concu, Alberto; Crisafulli, Antonio

    2014-01-29

    The beneficial effects of beetroot juice supplementation (BJS) have been tested during cycling, walking, and running. The purpose of the present study was to investigate whether BJS can also improve performance in swimmers. Fourteen moderately trained male master swimmers were recruited and underwent two incremental swimming tests randomly assigned in a pool during which workload, oxygen uptake (VO₂), carbon dioxide production (VCO₂), pulmonary ventilation (VE), and aerobic energy cost (AEC) of swimming were measured. One was a control swimming test (CSW) and the other a swimming test after six days of BJS (0.5 l/day organic beetroot juice containing about 5.5 mmol of NO₃⁻). Results show that workload at anaerobic threshold was significantly increased by BJS as compared to the CSW test (6.3 ± 1 and 6.7 ± 1.1 kg during the CSW and the BJS test respectively). Moreover, AEC was significantly reduced during the BJS test (1.9 ± 0.5 during the SW test vs. 1.7 ± 0.3 kcal·kg⁻¹1·h⁻¹ during the BJS test). The other variables lacked a statistically significant effect with BJS. The present investigation provides evidence that BJS positively affects performance of swimmers as it reduces the AEC and increases the workload at anaerobic threshold.

  9. OpenSim Model Improvements to Support High Joint Angle Resistive Exercising

    NASA Technical Reports Server (NTRS)

    Gallo, Christopher; Thompson, William; Lewandowski, Beth; Humphreys, Brad

    2016-01-01

    Long duration space travel to Mars or to an asteroid will expose astronauts to extended periods of reduced gravity. Since gravity is not present to aid loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to minimize the loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the area available for an exercise device in the next generation of spacecraft is limited. Therefore, compact resistance exercise device prototypes are being developed. The Advanced Resistive Exercise Device (ARED) currently on the ISS is being used as a benchmark for the functional performance of these new devices. Rigorous testing of these proposed devices in space flight is difficult so computational modeling provides an estimation of the muscle forces and joint loads during exercise to gain insight on the efficacy to protect the musculoskeletal health of astronauts. The NASA Digital Astronaut Project (DAP) is supporting the Advanced Exercise Concepts (AEC) Project, Exercise Physiology and Countermeasures (ExPC) project and the National Space Biomedical Research Institute (NSBRI) funded researchers by developing computational models of exercising with these new advanced exercise device concepts

  10. Detection and Sizing of Fatigue Cracks in Steel Welds with Advanced Eddy Current Techniques

    NASA Astrophysics Data System (ADS)

    Todorov, E. I.; Mohr, W. C.; Lozev, M. G.

    2008-02-01

    Butt-welded specimens were fatigued to produce cracks in the weld heat-affected zone. Advanced eddy current (AEC) techniques were used to detect and size the cracks through a coating. AEC results were compared with magnetic particle and phased-array ultrasonic techniques. Validation through destructive crack measurements was also conducted. Factors such as geometry, surface treatment, and crack tightness interfered with depth sizing. AEC inspection techniques have the potential of providing more accurate and complete sizing flaw data for manufacturing and in-service inspections.

  11. Curcumin modulates the effect of histone modification on the expression of chemokines by type II alveolar epithelial cells in a rat COPD model.

    PubMed

    Gan, Lixing; Li, Chengye; Wang, Jian; Guo, Xuejun

    2016-01-01

    Studies have suggested that histone modification has a positive impact on various aspects associated with the progression of COPD. Histone deacetylase 2 (HDAC2) suppresses proinflammatory gene expression through deacetylation of core histones. To investigate the effect of histone modification on the expression of chemokines in type II alveolar epithelial cells (AEC II) in a rat COPD model and regulation of HDAC2 expression by curcumin in comparison with corticosteroid. The rat COPD model was established by cigarette smoke exposure and confirmed by histology and pathophysioloy. AEC II were isolated and cultured in vitro from the COPD models and control animals. The cells were treated with curcumin, corticosteroid, or trichostatin A, and messenger RNA (mRNA) expression of interleukin-8 (IL-8), monocyte chemoattractant protein-1 (MCP-1), and macrophage inflammatory protein-2α (MIP-2α) was assessed by quantitative real-time polymerase chain reaction (RT-PCR). The expression of HDAC2 was measured by Western blot. Chromatin immunoprecipitation was used to detect H3/H4 acetylation and H3K9 methylation in the promoter region of three kinds of chemokine genes (IL-8, MCP-1, and MIP-2α). Compared to the control group, the mRNAs of MCP-1, IL-8, and MIP-2α were upregulated 4.48-fold, 3.14-fold, and 2.83-fold, respectively, in the AEC II from COPD model. The protein expression of HDAC2 in the AEC II from COPD model was significantly lower than from the control group ( P <0.05). The decreased expression of HDAC2 was negatively correlated with the increased expression of IL-8, MCP-1, and MIP-2α mRNAs (all P <0.05). The level of H3/H4 acetylation was higher but H3K9 methylation in the promoter region of chemokine genes was lower in the cells from COPD model than from the control group (all P <0.05). Curcumin downregulated the expression of MCP-1, IL-8, and MIP-2α, and the expression was further enhanced in the presence of corticosteroid. Moreover, curcumin restored HDAC2 expression, decreased the levels of H3/H4 acetylation, and increased H3K9 methylation in the promoter region of chemokine in the presence or absence of dexamethasone (all P <0.05). Curcumin may suppress chemokines and restore corticosteroid resistance in COPD through modulating HDAC2 expression and its effect on histone modification.

  12. Pretreatment with alcoholic extract of Crataegus oxycantha (AEC) activates mitochondrial protection during isoproterenol - induced myocardial infarction in rats.

    PubMed

    Jayalakshmi, R; Thirupurasundari, C J; Devaraj, S Niranjali

    2006-11-01

    Crataegus oxycantha (hawthorn) is used in herbal and homeopathic medicine as a cardiotonic. The present study was done to investigate the effect of the alcoholic extract of Crataegus oxycantha (AEC) on mitochondrial function during experimentally induced myocardial infarction in rat. AEC was administered orally to male albino rats (150-200 g), at a dosage of 0.5 ml/100 g body weight/day, for 30 days. At the end of the experimental period, the animals were administered isoproterenol (85 mg/kg body weight, s.c) for 2 days at an interval of 24 h. After 48 h, the rats were anaesthetized and sacrificed. The hearts were homogenized for biochemical and electron microscopic analysis. AEC pretreatment maintained mitochondrial antioxidant status, prevented mitochondrial lipid peroxidative damage and decrease in Kreb's cycle enzymes induced by isoproterenol in rat heart.

  13. A practical method to standardise and optimise the Philips DoseRight 2.0 CT automatic exposure control system.

    PubMed

    Wood, T J; Moore, C S; Stephens, A; Saunderson, J R; Beavis, A W

    2015-09-01

    Given the increasing use of computed tomography (CT) in the UK over the last 30 years, it is essential to ensure that all imaging protocols are optimised to keep radiation doses as low as reasonably practicable, consistent with the intended clinical task. However, the complexity of modern CT equipment can make this task difficult to achieve in practice. Recent results of local patient dose audits have shown discrepancies between two Philips CT scanners that use the DoseRight 2.0 automatic exposure control (AEC) system in the 'automatic' mode of operation. The use of this system can result in drifting dose and image quality performance over time as it is designed to evolve based on operator technique. The purpose of this study was to develop a practical technique for configuring examination protocols on four CT scanners that use the DoseRight 2.0 AEC system in the 'manual' mode of operation. This method used a uniform phantom to generate reference images which form the basis for how the AEC system calculates exposure factors for any given patient. The results of this study have demonstrated excellent agreement in the configuration of the CT scanners in terms of average patient dose and image quality when using this technique. This work highlights the importance of CT protocol harmonisation in a modern Radiology department to ensure both consistent image quality and radiation dose. Following this study, the average radiation dose for a range of CT examinations has been reduced without any negative impact on clinical image quality.

  14. RADIATION MONITOR CONTAINING TWO CONCENTRIC IONIZATION CHAMBERS AND MEANS FOR INSULATING THE SEPARATE CHAMBERS

    DOEpatents

    Braestrup, C.B.; Mooney, R.T.

    1964-01-21

    This invention relates to a portable radiation monitor containing two concentric ionization chambers which permit the use of standard charging and reading devices. It is particularly adapted as a personnel x-ray dosimeter and to this end comprises a small thin walled, cylindrical conductor forming an inner energy dependent chamber, a small thin walled, cylindrical conductor forming an outer energy independent chamber, and polymeric insulation means which insulates said chambers from each other and holds the chambers together with exposed connections in a simple, trouble-free, and compact assembly substantially without variation in directional response. (AEC)

  15. PRECISION INTEGRATOR FOR MINUTE ELECTRIC CURRENTS

    DOEpatents

    Hemmendinger, A.; Helmer, R.J.

    1961-10-24

    An integrator is described for measuring the value of integrated minute electrical currents. The device consists of a source capacitor connected in series with the source of such electrical currents, a second capacitor of accurately known capacitance and a source of accurately known and constant potential, means responsive to the potentials developed across the source capacitor for reversibly connecting the second capacitor in series with the source of known potential and with the source capacitor and at a rate proportional to the potential across the source capacitor to maintain the magnitude of the potential across the source capacitor at approximately zero. (AEC)

  16. CARMA3 Is Critical for the Initiation of Allergic Airway Inflammation

    PubMed Central

    Causton, Benjamin; Ramadas, Ravisankar A.; Cho, Josalyn L.; Jones, Khristianna; Pardo-Saganta, Ana; Rajagopal, Jayaraj; Xavier, Ramnik J.

    2015-01-01

    Innate immune responses to allergens by airway epithelial cells (AECs) help initiate and propagate the adaptive immune response associated with allergic airway inflammation in asthma. Activation of the transcription factor NF-κB in AECs by allergens or secondary mediators via G protein–coupled receptors (GPCRs) is an important component of this multifaceted inflammatory cascade. Members of the caspase recruitment domain family of proteins display tissue-specific expression and help mediate NF-κB activity in response to numerous stimuli. We have previously shown that caspase recruitment domain–containing membrane-associated guanylate kinase protein (CARMA)3 is specifically expressed in AECs and mediates NF-κB activation in these cells in response to stimulation with the GPCR agonist lysophosphatidic acid. In this study, we demonstrate that reduced levels of CARMA3 in normal human bronchial epithelial cells decreases the production of proasthmatic mediators in response to a panel of asthma-relevant GPCR ligands such as lysophosphatidic acid, adenosine triphosphate, and allergens that activate GPCRs such as Alternaria alternata and house dust mite. We then show that genetically modified mice with CARMA3-deficient AECs have reduced airway eosinophilia and proinflammatory cytokine production in a murine model of allergic airway inflammation. Additionally, we demonstrate that these mice have impaired dendritic cell maturation in the lung and that dendritic cells from mice with CARMA3-deficient AECs have impaired Ag processing. In conclusion, we show that AEC CARMA3 helps mediate allergic airway inflammation, and that CARMA3 is a critical signaling molecule bridging the innate and adaptive immune responses in the lung. PMID:26041536

  17. Gastroprotective Effect of Freeze Dried Stripped Snakehead Fish (Channa striata Bloch.) Aqueous Extract against Aspirin Induced Ulcerogenesis in Pylorus Ligated Rats.

    PubMed

    Ali Khan, Mohammed Safwan; Mat Jais, Abdul Manan; Hussain, Javeed; Siddiqua, Faiza; Gopala Reddy, A; Shivakumar, P; Madhuri, D

    2014-01-01

    Channa striata (Bloch.) is a fresh water fish belonging to the family Channidae. The stripped snakehead fish possesses wide range of medicinal properties. In view of traditional use of C. striata for wound healing, the present study was undertaken to investigate the beneficial effects of orally administered freeze dried aqueous extract of Channa striata (AECS) in experimentally induced gastric ulcers in Wistar rats. Aspirin induced ulcerogenesis in pyloric ligation model was used for the assessment of antiulcer activity and Ranitidine (50 mg/kg) was employed as the standard drug. The various gastric parameters like volume of gastric juice, pH, free and total acidities, ulcer index, and levels of antioxidant enzymes like catalase, superoxide dismutase, and lipid peroxidation marker malondialdehyde were determined. AECS at concentrations of 40% and 50% w/v significantly decreased the volume of gastric juice and increased the levels of catalase while considerable decrease in free and total acidities and increase in superoxide dismutase were observed with the treatment of standard drug and AECS (50% w/v). All the test doses of AECS markedly decreased ulcer index and malondialdehyde compared to the standard drug whereas AECS 30% w/v did not alter volume of gastric juice, pH, free and total acidities, catalase, and superoxide dismutase. From these findings, it can be concluded that AECS is devoid of acid neutralizing effects at lower doses and possesses antisecretory and antiulcer activities and this could be related to its antioxidant mechanism.

  18. Atmosphere Explorer control system software (version 1.0)

    NASA Technical Reports Server (NTRS)

    Villasenor, A.

    1972-01-01

    The basic design is described of the Atmosphere Explorer Control System (AECS) software used in the testing, integration, and flight contol of the AE spacecraft and experiments. The software performs several vital functions, such as issuing commands to the spacecraft and experiments, receiving and processing telemetry data, and allowing for extensive data processing by experiment analysis programs. The major processing sections are: executive control section, telemetry decommutation section, command generation section, and utility section.

  19. 10 CFR 760.1 - Uranium leases on lands controlled by DOE. (Domestic Uranium Program Circular No. 760.1, formerly...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Uranium leases on lands controlled by DOE. (Domestic Uranium Program Circular No. 760.1, formerly (AEC) Domestic Uranium Program Circular 8, 10 CFR 60.8). 760.1 Section 760.1 Energy DEPARTMENT OF ENERGY DOMESTIC URANIUM PROGRAM § 760.1 Uranium leases on lands...

  20. 10 CFR 760.1 - Uranium leases on lands controlled by DOE. (Domestic Uranium Program Circular No. 760.1, formerly...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 4 2013-01-01 2013-01-01 false Uranium leases on lands controlled by DOE. (Domestic Uranium Program Circular No. 760.1, formerly (AEC) Domestic Uranium Program Circular 8, 10 CFR 60.8). 760.1 Section 760.1 Energy DEPARTMENT OF ENERGY DOMESTIC URANIUM PROGRAM § 760.1 Uranium leases on lands...

  1. 10 CFR 760.1 - Uranium leases on lands controlled by DOE. (Domestic Uranium Program Circular No. 760.1, formerly...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 4 2012-01-01 2012-01-01 false Uranium leases on lands controlled by DOE. (Domestic Uranium Program Circular No. 760.1, formerly (AEC) Domestic Uranium Program Circular 8, 10 CFR 60.8). 760.1 Section 760.1 Energy DEPARTMENT OF ENERGY DOMESTIC URANIUM PROGRAM § 760.1 Uranium leases on lands...

  2. 10 CFR 760.1 - Uranium leases on lands controlled by DOE. (Domestic Uranium Program Circular No. 760.1, formerly...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 4 2014-01-01 2014-01-01 false Uranium leases on lands controlled by DOE. (Domestic Uranium Program Circular No. 760.1, formerly (AEC) Domestic Uranium Program Circular 8, 10 CFR 60.8). 760.1 Section 760.1 Energy DEPARTMENT OF ENERGY DOMESTIC URANIUM PROGRAM § 760.1 Uranium leases on lands...

  3. PROCESS FOR MAKING NEUTRON-ABSORBING BODIES

    DOEpatents

    Schippereit, G.H.; Lang, R.M.

    1961-11-14

    A process for making a control element for a nuclear reactor and the control element prepared by the process are described. Equally spaced, conically shaped depressions are formed in one face of a metal plate, spheres of boron of uniform size are placed in the depressions, another plate is welded on top of this place covering the depressions, and the joined plates are rolled to the desired thickness. (AEC)

  4. 10 CFR 760.1 - Uranium leases on lands controlled by DOE. (Domestic Uranium Program Circular No. 760.1, formerly...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Uranium leases on lands controlled by DOE. (Domestic Uranium Program Circular No. 760.1, formerly (AEC) Domestic Uranium Program Circular 8, 10 CFR 60.8). 760.1 Section 760.1 Energy DEPARTMENT OF ENERGY DOMESTIC URANIUM PROGRAM § 760.1 Uranium leases on lands...

  5. GRIPPING TOOL

    DOEpatents

    Sandrock, R.J.

    1961-12-12

    A self-actuated gripping tool is described for transferring fuel elements and the like into reactors and other inaccessible locations. The tool will grasp or release the load only when properly positioned for this purpose. In addition, the load cannot be released except when unsupported by the tool, so that jarring or contact will not bring about accidental release of the load. The gripping members or jaws of the device are cam-actuated by an axially slidable shaft which has two lockable positions. A spring urges the shaft into one position and a solenoid is provided to overcome the spring and move it into the other position. The weight of the tool operates a sleeve to lock the shaft in its existing position. Only when the cable supporting the tool is slack is the device capable of being actuated either to grasp or release its load. (AEC)

  6. The Role of Mitochondrial DNA in Mediating Alveolar Epithelial Cell Apoptosis and Pulmonary Fibrosis

    PubMed Central

    Kim, Seok-Jo; Cheresh, Paul; Jablonski, Renea P.; Williams, David B.; Kamp, David W.

    2015-01-01

    Convincing evidence has emerged demonstrating that impairment of mitochondrial function is critically important in regulating alveolar epithelial cell (AEC) programmed cell death (apoptosis) that may contribute to aging-related lung diseases, such as idiopathic pulmonary fibrosis (IPF) and asbestosis (pulmonary fibrosis following asbestos exposure). The mammalian mitochondrial DNA (mtDNA) encodes for 13 proteins, including several essential for oxidative phosphorylation. We review the evidence implicating that oxidative stress-induced mtDNA damage promotes AEC apoptosis and pulmonary fibrosis. We focus on the emerging role for AEC mtDNA damage repair by 8-oxoguanine DNA glycosylase (OGG1) and mitochondrial aconitase (ACO-2) in maintaining mtDNA integrity which is important in preventing AEC apoptosis and asbestos-induced pulmonary fibrosis in a murine model. We then review recent studies linking the sirtuin (SIRT) family members, especially SIRT3, to mitochondrial integrity and mtDNA damage repair and aging. We present a conceptual model of how SIRTs modulate reactive oxygen species (ROS)-driven mitochondrial metabolism that may be important for their tumor suppressor function. The emerging insights into the pathobiology underlying AEC mtDNA damage and apoptosis is suggesting novel therapeutic targets that may prove useful for the management of age-related diseases, including pulmonary fibrosis and lung cancer. PMID:26370974

  7. APPARATUS FOR TRAPPING ENERGETIC CHARGED PARTICLES AND CONFINING THE RESULTING PLASMA

    DOEpatents

    Gibson, G.; Jordan, W.C.; Lauer, E.J.

    1963-04-01

    The present invention relates to a plasma-confining device and a particle injector therefor, the device utilizing a generally toroidal configuration with magnetic fields specifically tailored to the associated injector. The device minimizes the effects of particle end losses and particle drift to the walls with a relatively simple configuration. More particularly, the magnetic field configuration is created by a continuous array of circular, mirror field coils, disposed side-by- side, in particularly spaced relation, to form an endless, toroidal loop. The resulting magnetic field created therein has the appearance of a bumpy'' torus, from which is derived the name Bumpy Torus.'' One of the aforementioned coils is split transverse to its axis, and injection of particles is accomplished along a plane between the halves of such modified coil. The guiding center of the particles follows a constant magnetic field in the plane for a particular distance within the torus, to move therefrom onto a precessional surface which does not intersect the point of injection. (AEC)

  8. SPRING DRIVEN ACTUATING MECHANISM FOR NUCLEAR REACTOR CONTROL

    DOEpatents

    Bevilacqua, F.; Uecker, D.F.; Groh, E.F.

    1962-01-23

    l962. rod in a nuclear reactor to shut it down. The control rod or an extension thereof is wound on a drum as it is withdrawn from the reactor. When an emergency occurs requiring the reactor to be shut down, the drum is released so as to be free to rotate, and the tendency of the control rod or its extension coiled on the drum to straighten itself is used for quickly returning the control rod to the reactor. (AEC)

  9. Commercial Nuclear Steam-Electric Power Plants, Part II

    ERIC Educational Resources Information Center

    Shore, Ferdinand J.

    1974-01-01

    Presents the pros and cons of nuclear power systems. Includes a discussion of the institutional status of the AEC, AEC regulatory record, routine low-level radiation hazards, transport of radioactive materials, storage of wastes, and uranium resources and economics of supply. (GS)

  10. Inflammatory caspases are critical for enhanced cell death in the target tissue of Sjögren’s syndrome prior to disease onset

    PubMed Central

    Bulosan, Marievic; Pauley, Kaleb; Yo, Kyumee; Chan, Edward K.; Katz, Joseph; Peck, Ammon B.; Cha, Seunghee

    2015-01-01

    To date, little is known why exocrine glands are subject to immune cell infiltrations in Sjögren’s syndrome (SjS). Studies with SjS-prone-C57BL/6.NOD-Aec1Aec2 mice showed altered glandular homeostasis in the submandibular glands (SMX) at 8 weeks prior to disease onset and suggested potential involvement of inflammatory caspases (caspases-11 and -1). To determine if inflammatory caspases are critical for the increased epithelial cell death prior to SjS-like disease, we investigated molecular events involving caspase-11/caspase-1 axis. Our results revealed concurrent up-regulation of caspase-11 in macrophages, STAT-1 activity, caspase-1 activity, and apoptotic epithelial cells in the SMX of C57BL/6.NOD-Aec1Aec2 at 8 weeks. Caspase-1, a critical factor for IL-1β and IL-18 secretion, resulted in elevated level of IL-18 in saliva. Interestingly, TUNEL-positive cells in the SMX of C57BL/6.NOD-Aec1Aec2 were not co-localized with caspase-11, indicating that caspase-11 functions in a non-cell autonomous manner. Increased apoptosis of a human salivary gland (HSG) cell line occurred only in the presence of LPS-and IFN-γ-stimulated human monocytic THP-1 cells, which was reversed when caspase-1 in THP-1 cells was targeted by siRNA. Taken together, our study discovered that inflammatory caspases are essential in promoting pro-inflammatory microenvironment and influencing increased epithelial cell death in the target tissues of SjS before disease onset. PMID:18936772

  11. CARMA3 Is Critical for the Initiation of Allergic Airway Inflammation.

    PubMed

    Causton, Benjamin; Ramadas, Ravisankar A; Cho, Josalyn L; Jones, Khristianna; Pardo-Saganta, Ana; Rajagopal, Jayaraj; Xavier, Ramnik J; Medoff, Benjamin D

    2015-07-15

    Innate immune responses to allergens by airway epithelial cells (AECs) help initiate and propagate the adaptive immune response associated with allergic airway inflammation in asthma. Activation of the transcription factor NF-κB in AECs by allergens or secondary mediators via G protein-coupled receptors (GPCRs) is an important component of this multifaceted inflammatory cascade. Members of the caspase recruitment domain family of proteins display tissue-specific expression and help mediate NF-κB activity in response to numerous stimuli. We have previously shown that caspase recruitment domain-containing membrane-associated guanylate kinase protein (CARMA)3 is specifically expressed in AECs and mediates NF-κB activation in these cells in response to stimulation with the GPCR agonist lysophosphatidic acid. In this study, we demonstrate that reduced levels of CARMA3 in normal human bronchial epithelial cells decreases the production of proasthmatic mediators in response to a panel of asthma-relevant GPCR ligands such as lysophosphatidic acid, adenosine triphosphate, and allergens that activate GPCRs such as Alternaria alternata and house dust mite. We then show that genetically modified mice with CARMA3-deficient AECs have reduced airway eosinophilia and proinflammatory cytokine production in a murine model of allergic airway inflammation. Additionally, we demonstrate that these mice have impaired dendritic cell maturation in the lung and that dendritic cells from mice with CARMA3-deficient AECs have impaired Ag processing. In conclusion, we show that AEC CARMA3 helps mediate allergic airway inflammation, and that CARMA3 is a critical signaling molecule bridging the innate and adaptive immune responses in the lung. Copyright © 2015 by The American Association of Immunologists, Inc.

  12. Reliability and Failure Modes of Solid-State Lighting Electrical Drivers Subjected to Accelerated Aging

    DOE PAGES

    Lall, Pradeep; Sakalaukus, Peter; Davis, Lynn

    2015-02-19

    An investigation of an off-the-shelf solid-state lighting device with the primary focus on the accompanied light-emitting diode (LED) electrical driver (ED) has been conducted. A set of 10 EDs were exposed to temperature humidity life testing of 85% RH and 85 C (85/85) without an electrical bias per the JEDEC standard JESD22-A101C in order to accelerate the ingress of moisture into the aluminum electrolytic capacitor (AEC) and the EDs in order to assess the reliability of the LED drivers for harsh environment applications. The capacitance and equivalent series resistance for each AEC inside the ED were measured using a handheldmore » LCR meter as possible leading indications of failure. The photometric quantities of a single pristine light engine were monitored in order to investigate the interaction between the light engine and the EDs. These parameters were used in assessing the overall reliability of the EDs. In addition, a comparative analysis has been conducted between the 85/85 accelerated test data and a previously published high-temperature storage life accelerated test of 135°C. The results of the 85/85 acceleration test and the comparative analysis are presented in this paper.« less

  13. History of Nuclear India

    NASA Astrophysics Data System (ADS)

    Chaturvedi, Ram

    2000-04-01

    India emerged as a free and democratic country in 1947, and entered into the nuclear age in 1948 by establishing the Atomic Energy Commission (AEC), with Homi Bhabha as the chairman. Later on the Department of Atomic Energy (DAE) was created under the Office of the Prime Minister Jawahar Lal Nehru. Initially the AEC and DAE received international cooperation, and by 1963 India had two research reactors and four nuclear power reactors. In spite of the humiliating defeat in the border war by China in 1962 and China's nuclear testing in 1964, India continued to adhere to the peaceful uses of nuclear energy. On May 18, 1974 India performed a 15 kt Peaceful Nuclear Explosion (PNE). The western powers considered it nuclear weapons proliferation and cut off all financial and technical help, even for the production of nuclear power. However, India used existing infrastructure to build nuclear power reactors and exploded both fission and fusion devices on May 11 and 13, 1998. The international community viewed the later activity as a serious road block for the Non-Proliferation Treaty and the Comprehensive Test Ban Treaty; both deemed essential to stop the spread of nuclear weapons. India considers these treaties favoring nuclear states and is prepared to sign if genuine nuclear disarmament is included as an integral part of these treaties.

  14. FREQUENCY CONTROL OF RF HEATING OF GASEOUS PLASMA

    DOEpatents

    Herold, E.W.

    1962-09-01

    This invention relates to the heating of gaseous plasma by radiofrequency ion-cyclotron resonance heating. The cyclotron resonance frequencies are varied and this invention provides means for automatically controlling the frequency of the radiofrequency to maximize the rate of heating. To this end, a servo-loop is provided to sense the direction of plasma heating with frequency and a control signal is derived to set the center frequency of the radiofrequency energy employed to heat the plasma. (AEC)

  15. A Review of Communications Satellites and Related Spacecraft for Factors Influencing Mission Success. Volume 2

    DTIC Science & Technology

    1975-11-17

    and control (subsystem) COMM., comm AEC Atomic Energy Commission comsat AFB Air Force Base COMSTAR ACE A-hr aerospace ground equipment ampere...array TDA Satellite Assembly Building TDAL Space and Missile Systems Organization (U.S. Air Force) TDM THIR satellite communications system TI...Satellite Control Facility (U.S. Air Force) TIROS selective chopper radiometer TLM, T/M surface composition mapping radiometer TOS TRUST

  16. CONTROL ROD ROTATING MECHANISM

    DOEpatents

    Baumgarten, A.; Karalis, A.J.

    1961-11-28

    A threaded rotatable shaft is provided which rotates in response to linear movement of a nut, the shaft being surrounded by a pair of bellows members connected to either side of the nut to effectively seal the reactor from leakage and also to store up energy to shut down the reactor in the event of a power failure. (AEC)

  17. DEMONSTRATION BULLETIN: SITE CHARACTERIZATION ANALYSIS PENETROMETER SYSTEM (SCAPS) LIF SENSOR - U.S. ARMY, NAVY, AND AIR FORCE (TRI-SERVICES)

    EPA Science Inventory

    The Tri-Services Site Characterization Analysis Penetrometer System (SCAPS) was developed by the U.S. Army (U.S. Army Corps of Engineers, Waterways Experiment Station [WES] and the Army Environmental Center [AEC]), Navy (Naval Command, Control and Ocean Surveillance Center), and ...

  18. WATER TREATMENT

    DOEpatents

    Pitman, R.W.; Conley, W.R. Jr.

    1962-12-01

    An automated system for adding clarifying chemicals to water in a water treatment plant is described. To a sample of the floc suspension polyacrylamide or similar filter aid chemicals are added, and the sample is then put through a fast filter. The resulting filtrate has the requisite properties for monitoring in an optical turbidimeter to control the automated system. (AEC)

  19. Dose Estimating Application Software Modification: Additional Function of a Size-Specific Effective Dose Calculator and Auto Exposure Control.

    PubMed

    Kobayashi, Masanao; Asada, Yasuki; Matsubara, Kosuke; Suzuki, Shouichi; Matsunaga, Yuta; Haba, Tomonobu; Kawaguchi, Ai; Daioku, Tomihiko; Toyama, Hiroshi; Kato, Ryoichi

    2017-05-01

    Adequate dose management during computed tomography is important. In the present study, the dosimetric application software ImPACT was added to a functional calculator of the size-specific dose estimate and was part of the scan settings for the auto exposure control (AEC) technique. This study aimed to assess the practicality and accuracy of the modified ImPACT software for dose estimation. We compared the conversion factors identified by the software with the values reported by the American Association of Physicists in Medicine Task Group 204, and we noted similar results. Moreover, doses were calculated with the AEC technique and a fixed-tube current of 200 mA for the chest-pelvis region. The modified ImPACT software could estimate each organ dose, which was based on the modulated tube current. The ability to perform beneficial modifications indicates the flexibility of the ImPACT software. The ImPACT software can be further modified for estimation of other doses. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Experiments in progress: The geography of science in the Atomic Energy Commission's peaceful uses of nuclear explosives program, 1956-1973

    NASA Astrophysics Data System (ADS)

    Kirsch, Scott Lawrence

    From 1957 to 1973, the United States Atomic Energy Commission (AEC) actively pursued the "peaceful uses of nuclear explosives" through Project Plowshare. Nuclear excavation, the detonation of shallowly buried hydrogen bombs for massive earthmoving projects like harbors and canals, was considered the most promising of the Plowshare applications, and for a time, the most economically and technically "feasible." With a basis in and contributing to theory in critical human geography and science studies, the purpose of this dissertation is to examine the collisions of science, ideology, and politics which kept Plowshare designs alive--but only as "experiments in progress." That is, this research asks how the experimental program persisted in places like the national weapons laboratory in Livermore, California, and how its ideas were tested at the nuclear test site in Nevada, yet Plowshare was kept out of those spaces beyond AEC control. Primary research focuses on AEC-related archival materials collected from the Department of Energy Coordination and Information Center, Las Vegas, Nevada, and from the Lawrence Livermore National Laboratory, as well as the public discourse through which support for and opposition to Plowshare projects was voiced. Through critical analysis of Plowshare's grandiose "geographical engineering" schemes, I thus examine the complex relations between the social construction of science and technology, on one hand, and the social production of space, on the other.

  1. LOGIC CIRCUIT

    DOEpatents

    Strong, G.H.; Faught, M.L.

    1963-12-24

    A device for safety rod counting in a nuclear reactor is described. A Wheatstone bridge circuit is adapted to prevent de-energizing the hopper coils of a ball backup system if safety rods, sufficient in total control effect, properly enter the reactor core to effect shut down. A plurality of resistances form one arm of the bridge, each resistance being associated with a particular safety rod and weighted in value according to the control effect of the particular safety rod. Switching means are used to switch each of the resistances in and out of the bridge circuit responsive to the presence of a particular safety rod in its effective position in the reactor core and responsive to the attainment of a predetermined velocity by a particular safety rod enroute to its effective position. The bridge is unbalanced in one direction during normal reactor operation prior to the generation of a scram signal and the switching means and resistances are adapted to unbalance the bridge in the opposite direction if the safety rods produce a predetermined amount of control effect in response to the scram signal. The bridge unbalance reversal is then utilized to prevent the actuation of the ball backup system, or, conversely, a failure of the safety rods to produce the predetermined effect produces no unbalance reversal and the ball backup system is actuated. (AEC)

  2. [Study of CT Automatic Exposure Control System (CT-AEC) Optimization in CT Angiography of Lower Extremity Artery by Considering Contrast-to-Noise Ratio].

    PubMed

    Inada, Satoshi; Masuda, Takanori; Maruyama, Naoya; Yamashita, Yukari; Sato, Tomoyasu; Imada, Naoyuki

    2016-01-01

    To evaluate the image quality and effect of radiation dose reduction by setting for computed tomography automatic exposure control system (CT-AEC) in computed tomographic angiography (CTA) of lower extremity artery. Two methods of setting were compared for CT-AEC [conventional and contrast-to-noise ratio (CNR) methods]. Conventional method was set noise index (NI): 14and tube current threshold: 10-750 mA. CNR method was set NI: 18, minimum tube current: (X+Y)/2 mA (X, Y: maximum X (Y)-axis tube current value of leg in NI: 14), and maximum tube current: 750 mA. The image quality was evaluated by CNR, and radiation dose reduction was evaluated by dose-length-product (DLP). In conventional method, mean CNRs for pelvis, femur, and leg were 19.9±4.8, 20.4±5.4, and 16.2±4.3, respectively. There was a significant difference between the CNRs of pelvis and leg (P<0.001), and between femur and leg (P<0.001). In CNR method, mean CNRs for pelvis, femur, and leg were 15.2±3.3, 15.3±3.2, and 15.3±3.1, respectively; no significant difference between pelvis, femur, and leg (P=0.973) in CNR method was observed. Mean DLPs were 1457±434 mGy⋅cm in conventional method, and 1049±434 mGy·cm in CNR method. There was a significant difference in the DLPs of conventional method and CNR method (P<0.001). CNR method gave equal CNRs for pelvis, femur, and leg, and was beneficial for radiation dose reduction in CTA of lower extremity artery.

  3. Ceramic R and D Programs. Part III. NASA, ARPA, AEC, NBS, Bureau of Mines, and National Science Foundation.

    DTIC Science & Technology

    The report is a DCIC compilation of current R and D programs that are supported by NASA, ARPA, AEC, NBS, Bureau of Mines, and National Science Foundation in the field of ceramics and related materials. (Author)

  4. Vaccination with human amniotic epithelial cells confer effective protection in a murine model of Colon adenocarcinoma.

    PubMed

    Tabatabaei, M; Mosaffa, N; Ghods, R; Nikoo, S; Kazemnejad, S; Khanmohammadi, M; Mirzadeghan, E; Mahmoudi, A R; Bolouri, M R; Falak, R; Keshavarzi, B; Ramezani, M; Zarnani, A H

    2018-04-01

    As a prophylactic cancer vaccine, human amniotic membrane epithelial cells (hAECs) conferred effective protection in a murine model of colon cancer. The immunized mice mounted strong cross-protective CTL and antibody responses. Tumor burden was significantly reduced in tumor-bearing mice after immunization with hAECs. Placental cancer immunotherapy could be a promising approach for primary prevention of cancer. In spite of being the star of therapeutic strategies for cancer treatment, the results of immunotherapeutic approaches are still far from expectations. In this regard, primary prevention of cancer using prophylactic cancer vaccines has gained considerable attention. The immunologic similarities between cancer development and placentation have helped researchers to unravel molecular mechanisms responsible for carcinogenesis and to take advantage of stem cells from reproductive organs to elicit robust anti-cancer immune responses. Here, we showed that vaccination of mice with human amniotic membrane epithelial cells (hAECs) conferred effective protection against colon cancer and led to expansion of systemic and splenic cytotoxic T cell population and induction of cross-protective cytotoxic responses against tumor cells. Vaccinated mice mounted tumor-specific Th1 responses and produced cross-reactive antibodies against cell surface markers of cancer cells. Tumor burden was also significantly reduced in tumor-bearing mice immunized with hAECs. Our findings pave the way for potential future application of hAECs as an effective prophylactic cancer vaccine. © 2017 UICC.

  5. An aqueous extract of Curcuma longa (turmeric) rhizomes stimulates insulin release and mimics insulin action on tissues involved in glucose homeostasis in vitro.

    PubMed

    Mohankumar, Sureshkumar; McFarlane, James R

    2011-03-01

    Curcuma longa (turmeric) has been used widely as a spice, particularly in Asian countries. It is also used in the Ayurvedic system of medicine as an antiinflammatory and antimicrobial agent and for numerous other curative properties. The aim of this study was to investigate the effects of an aqueous extract of Curcuma longa (AEC) on tissues involved in glucose homeostasis. The extract was prepared by soaking 100 g of ground turmeric in 1 L of water, which was filtered and stored at -20°C prior to use. Pancreas and muscle tissues of adult mice were cultured in DMEM with 5 or 12 mmol/L glucose and varying doses of extract. The AEC stimulated insulin secretion from mouse pancreatic tissues under both basal and hyperglycaemic conditions, although the maximum effect was only 68% of that of tolbutamide. The AEC induced stepwise stimulation of glucose uptake from abdominal muscle tissues in the presence and absence of insulin, and the combination of AEC and insulin significantly potentiated the glucose uptake into abdominal muscle tissue. However, this effect was attenuated by wortmannin, suggesting that AEC possibly acts via the insulin-mediated glucose uptake pathway. In summary, water soluble compounds of turmeric exhibit insulin releasing and mimicking actions within in vitro tissue culture conditions. Copyright © 2010 John Wiley & Sons, Ltd.

  6. CONTROL SYSTEM FOR NEUTRONIC REACTORS

    DOEpatents

    Crever, F.E.

    1962-05-01

    BS>A slow-acting shim rod for control of major variations in reactor neutron flux and a fast-acting control rod to correct minor flux variations are employed to provide a sensitive, accurate control system. The fast-acting rod is responsive to an error signal which is produced by changes in the neutron flux from a predetermined optimum level. When the fast rod is thus actuated in a given direction, means is provided to actuate the slow-moving rod in that direction to return the fast rod to a position near the midpoint of its control range. (AEC)

  7. DESTRUCTION OF NEUTRAL PARTICLES IN A DEVICE FOR PRODUCING A HIGH DENSITY PLASMA

    DOEpatents

    Simon, A.

    1962-05-01

    A method and apparatus are described for burning out neutral particles in an evacuated region and within a strong magnetic field. The method comprises injecting energetic molecular ions into the region perpendicular to the magnetic field and into the path of a dissociating, energetic arc discharge, the atomic ions formed in the dissociating process being trapped by the magnetic field, and then increasing the value of the trapped atomic ion current to such a value that the neutral particles are destroyed faster than they are formed, thereby causing a dense, energetic plasma to be built up and sustained by the magnetic field. (AEC)

  8. Monitoring of tylosin and sulfamethazine in a tile drained agricultural Watershed using (POCIS)

    USDA-ARS?s Scientific Manuscript database

    The seasonal occurrence, fate, and transport of agricultural emerging contaminants (AECs) was evaluated in the South Fork watershed of the Iowa River (SFIR) using Polar Organic Chemical Integrative Samplers (POCIS) over a three year period. The AECs of concern were tylosin (TYL) and sulfamethazine (...

  9. 320-row coronary computed tomography angiography (CCTA) with automatic exposure control (AEC): effect of 100 kV versus 120 kV on image quality and dose exposure.

    PubMed

    Di Cesare, Ernesto; Gennarelli, Antonio; Di Sibio, Alessandra; Felli, Valentina; Perri, Marco; Splendiani, Alessandra; Gravina, Giovanni Luca; Barile, Antonio; Masciocchi, Carlo

    2016-08-01

    To compare the impact of a 100 kV tube voltage protocol to 120 kV in terms of image quality and radiation dose by a 320 row coronary computed tomography angiography (CCTA) with automatic exposure control (AEC). Using a propensity matched analysis we compared a group of 135 patients scanned using a 100 kV tube voltage protocol with a group of 135 subjects scanned employing a 120 kV tube voltage setting. In all subjects the heart rate (HR) was <65 bpm and all CT scans were acquired using a prospective ECG gating and AEC strategy. Mean effective radiation dose and subjective and objective (Noise or N, signal to noise ratio or SNR, contrast to noise ratio or CNR) image quality, were evaluated. Subjective quality was assessed by two experienced radiologists using a 5-point scale (0: non diagnostic-4: excellent) using the 15-segment American Heart Association (AHA) coronary artery classification. Mean effective dose and noise were non significantly different between the two groups: mean effective dose was 2.89 ± 0.7 mSv in the 100 kV group and 2.80 ± 0.57 mSv in the 120 kV group (p = 0.25) while noise was 28.9 ± 3.3 in the 120 kV group and 29.05 ± 3.6 in the 100 kV group (p = 0.72). Both SNR and CNR were significantly higher in the 100 kV group than in the 120 kV group. This data agrees with the evidence that subjective quality was significantly higher in the 100 kV group in the middle and distal segmental classes. Our study shows that, in using a 320 row CCTA with AEC strategy it is better to employ a 100 kV tube voltage protocol because compared to 120 kV tube voltage setting, it appears to significantly improve both subjective and objective image quality without decreasing the mean effective radiation dose.

  10. Design logistics performance measurement model of automotive component industry for srengthening competitiveness of dealing AEC 2015

    NASA Astrophysics Data System (ADS)

    Amran, T. G.; Janitra Yose, Mindy

    2018-03-01

    As the free trade Asean Economic Community (AEC) causes the tougher competition, it is important that Indonesia’s automotive industry have high competitiveness as well. A model of logistics performance measurement was designed as an evaluation tool for automotive component companies to improve their logistics performance in order to compete in AEC. The design of logistics performance measurement model was based on the Logistics Scorecard perspectives, divided into two stages: identifying the logistics business strategy to get the KPI and arranging the model. 23 KPI was obtained. The measurement result can be taken into consideration of determining policies to improve the performance logistics competitiveness.

  11. Inhibition of CD23-mediated IgE transcytosis suppresses the initiation and development of airway allergic inflammation

    USDA-ARS?s Scientific Manuscript database

    The epithelium lining the airway tract and allergen-specific IgE are considered essential controllers of inflammatory responses to allergens. The human IgE receptor, CD23 (Fc'RII), is capable of transporting IgE or IgE-allergen complexes across the polarized human airway epithelial cell (AEC) monola...

  12. COMPOSITE CONTROL ROD

    DOEpatents

    Rock, H.R.

    1963-12-24

    A composite control rod for use in controlling a nuclear reactor is described. The control rod is of sandwich construction in which finned dowel pins are utilized to hold together sheets of the neutron absorbing material and nonabsorbing structural material thereby eliminating the need for being dependent on the absorbing material for structural support. The dowel pins perform the function of absorbing the forces due to differential thermal expansion, seating further with the fins into the sheets of material and crushing before damage is done either to the absorbing or non-absorbing material. (AEC)

  13. Monitoring tylosin and sulfamethazine in a tile-drained agricultural watershed using polar organic chemical integrative sampler (POCIS)

    USDA-ARS?s Scientific Manuscript database

    The seasonal occurrence, fate, and transport of agricultural emerging contaminants (AECs) was evaluated in the South Fork watershed of the Iowa River (SFIR) using Polar Organic Chemical Integrative Samplers (POCIS) over a three year period. The AECs of concern were tylosin (TYL) and sulfamethazine (...

  14. AEC Experiment Establishes Computer Link Between California and Paris

    Science.gov Websites

    demonstrated that a terminal in Paris could search a computer in California and display the resulting (Copies) AEC EXPERIMENT ESTABLISHES COMPUTER LINK BETWEEN CALIFORNIA AND PARIS The feasibility of a worldwide information retrieval system which would tie a computer base of information to terminals on the

  15. The effect of betaine on the foam stability: Molecular simulation

    NASA Astrophysics Data System (ADS)

    Gao, Fengfeng; Liu, Guokui; Yuan, Shiling

    2017-06-01

    Zwitterionic betaines are widely used as foam boosters due to these can enhance the stability of foam films. In this paper, mechanistic insights of betaine to improve the stability of alkyl-polyoxyethylene carboxylate (AEC) foam are provided by molecular simulation. In the simulation, we observe the electropositive nitrogen atoms in betaine interact with the electronegative sulfur atoms, an electrostatic structure is formed at the air/water interface. Interaction energies of the mixed surfactants are calculated by the quantum chemistry methods. The calculations show betaine-AEC and betaine-betaine possess attractive interaction, and that AEC-AEC has repulsion to each other. In the other words, the repulsion between the headgroups of anionic surfactants is relaxed by betaine. Additionally, the influence of concentration of betaine on the stability of foam films is also simulated. The RDF and coordination numbers show that the electrostatic structures become denser with the increasing concentration of betaine. Therefore, entry barrier is enhanced accordingly. The SMD simulation also demonstrates the same variation tendency of entry barrier. The simulation details provide vital supplements to experiments.

  16. CRISPR-Cas9-mediated gene knockout in primary human airway epithelial cells reveals a proinflammatory role for MUC18.

    PubMed

    Chu, H W; Rios, C; Huang, C; Wesolowska-Andersen, A; Burchard, E G; O'Connor, B P; Fingerlin, T E; Nichols, D; Reynolds, S D; Seibold, M A

    2015-10-01

    Targeted knockout of genes in primary human cells using CRISPR-Cas9-mediated genome-editing represents a powerful approach to study gene function and to discern molecular mechanisms underlying complex human diseases. We used lentiviral delivery of CRISPR-Cas9 machinery and conditional reprogramming culture methods to knockout the MUC18 gene in human primary nasal airway epithelial cells (AECs). Massively parallel sequencing technology was used to confirm that the genome of essentially all cells in the edited AEC populations contained coding region insertions and deletions (indels). Correspondingly, we found mRNA expression of MUC18 was greatly reduced and protein expression was absent. Characterization of MUC18 knockout cell populations stimulated with TLR2, 3 and 4 agonists revealed that IL-8 (a proinflammatory chemokine) responses of AECs were greatly reduced in the absence of functional MUC18 protein. Our results show the feasibility of CRISPR-Cas9-mediated gene knockouts in AEC culture (both submerged and polarized), and suggest a proinflammatory role for MUC18 in airway epithelial response to bacterial and viral stimuli.

  17. Immunogenicity and immunomodulatory properties of hepatocyte-like cells derived from human amniotic epithelial cells.

    PubMed

    Tee, Jing Yang; Vaghjiani, Vijesh; Liu, Yu Han; Murthi, Padma; Chan, James; Manuelpillai, Ursula

    2013-01-01

    Hepatocyte transplantation is being trialled as an alternative to whole organ transplant for patients with acute liver failure and liver specific metabolic diseases. Due to the scarcity of human hepatocytes, hepatocyte-like cells (HLC) generated from stem cells may become a viable alternative to hepatocyte transplantation. Human amniotic epithelial cells (hAEC) from the placenta have stem cell-like properties and can be differentiated into HLC. Naïve hAEC have low immunogenicity and exert immunomodulatory effects that may facilitate allogeneic transplantation. However, whether the immunogenicity and immunomodulatory properties alter with differentiation into HLC are unknown. We further characterized HLC generated from hAEC, examined changes in human leucocyte antigens (HLA) and co-stimulatory molecules and effects exerted by the HLC on human peripheral blood mononuclear cells (PBMC). HLC derived from hAEC expressed proteins found in hepatocytes, had CYP3A4 drug metabolizing enzyme activity and secreted urea. IFN-γ treatment increased HLA Class IA, Class II and co-stimulatory molecule CD40 expression in the HLC. IFN-γ treated HLC stimulated proliferation of PBMC in one-way mixed lymphocyte reactions and were more immunogenic than undifferentiated hAEC. However, the HLC showed immunomodulatory properties and inhibited mitogen induced PBMC proliferation in vitro. PBMC proliferation may have been inhibited by IL-6, TGF-β1, PGE2 and HLA-G secreted by the HLC. The retention of immunomodulatory properties may enable HLC grafts to survive for longer periods despite the immunogenicity of the HLC.

  18. SAFETY SYSTEM FOR CONTROL ROD

    DOEpatents

    Paget, J.A.

    1963-05-14

    A structure for monitoring the structural continuity of a control rod foi a neutron reactor is presented. A electric conductor readily breakable under mechanical stress is fastened along the length of the control rod at a plurality of positions and forms a closed circuit with remote electrical components responsive to an open circuit. A portion of the conductor between the control rod and said components is helically wound to allow free and normally unrestricted movement of the segment of conductor secured to the control rod relative to the remote components. Any break in the circuit is indicative of control rod breakage. (AEC)

  19. The effect of epoch length on estimated EEG functional connectivity and brain network organisation

    NASA Astrophysics Data System (ADS)

    Fraschini, Matteo; Demuru, Matteo; Crobe, Alessandra; Marrosu, Francesco; Stam, Cornelis J.; Hillebrand, Arjan

    2016-06-01

    Objective. Graph theory and network science tools have revealed fundamental mechanisms of functional brain organization in resting-state M/EEG analysis. Nevertheless, it is still not clearly understood how several methodological aspects may bias the topology of the reconstructed functional networks. In this context, the literature shows inconsistency in the chosen length of the selected epochs, impeding a meaningful comparison between results from different studies. Approach. The aim of this study was to provide a network approach insensitive to the effects that epoch length has on functional connectivity and network reconstruction. Two different measures, the phase lag index (PLI) and the amplitude envelope correlation (AEC) were applied to EEG resting-state recordings for a group of 18 healthy volunteers using non-overlapping epochs with variable length (1, 2, 4, 6, 8, 10, 12, 14 and 16 s). Weighted clustering coefficient (CCw), weighted characteristic path length (L w) and minimum spanning tree (MST) parameters were computed to evaluate the network topology. The analysis was performed on both scalp and source-space data. Main results. Results from scalp analysis show a decrease in both mean PLI and AEC values with an increase in epoch length, with a tendency to stabilize at a length of 12 s for PLI and 6 s for AEC. Moreover, CCw and L w show very similar behaviour, with metrics based on AEC more reliable in terms of stability. In general, MST parameters stabilize at short epoch lengths, particularly for MSTs based on PLI (1-6 s versus 4-8 s for AEC). At the source-level the results were even more reliable, with stability already at 1 s duration for PLI-based MSTs. Significance. The present work suggests that both PLI and AEC depend on epoch length and that this has an impact on the reconstructed network topology, particularly at the scalp-level. Source-level MST topology is less sensitive to differences in epoch length, therefore enabling the comparison of brain network topology between different studies.

  20. Key Role of MicroRNA in the Regulation of Granulocyte Macrophage Colony-stimulating Factor Expression in Murine Alveolar Epithelial Cells during Oxidative Stress*

    PubMed Central

    Sturrock, Anne; Mir-Kasimov, Mustafa; Baker, Jessica; Rowley, Jesse; Paine, Robert

    2014-01-01

    GM-CSF is an endogenous pulmonary cytokine produced by normal alveolar epithelial cells (AEC) that is a key defender of the alveolar space. AEC GM-CSF expression is suppressed by oxidative stress through alternations in mRNA turnover, an effect that is reversed by treatment with recombinant GM-CSF. We hypothesized that specific microRNA (miRNA) would play a key role in AEC GM-CSF regulation. A genome-wide miRNA microarray identified 19 candidate miRNA altered in primary AEC during oxidative stress with reversal by treatment with GM-CSF. Three of these miRNA (miR 133a, miR 133a*, and miR 133b) are also predicted to bind the GM-CSF 3′-untranslated region (UTR). PCR for the mature miRNA confirmed induction during oxidative stress that was reversed by treatment with GM-CSF. Experiments using a GM-CSF 3′-UTR reporter construct demonstrated that miR133a and miR133b effects on GM-CSF expression are through interactions with the GM-CSF 3′-UTR. Using lentiviral transduction of specific mimics and inhibitors in primary murine AEC, we determined that miR133a and miR133b suppress GM-CSF expression and that their inhibition both reverses oxidant-induced suppression of GM-CSF expression and increases basal expression of GM-CSF in cells in normoxia. In contrast, these miRNAs are not active in regulation of GM-CSF expression in murine EL4 T cells. Thus, members of the miR133 family play key roles in regulation of GM-CSF expression through effects on mRNA turnover in AEC during oxidative stress. Increased understanding of GM-CSF gene regulation may provide novel miRNA-based interventions to augment pulmonary innate immune defense in lung injury. PMID:24371146

  1. CdiA Effectors from Uropathogenic Escherichia coli Use Heterotrimeric Osmoporins as Receptors to Recognize Target Bacteria

    PubMed Central

    Beck, Christina M.; Willett, Julia L. E.; Kim, Jeff J.; Low, David A.; Hayes, Christopher S.

    2016-01-01

    Many Gram-negative bacterial pathogens express contact-dependent growth inhibition (CDI) systems that promote cell-cell interaction. CDI+ bacteria express surface CdiA effector proteins, which transfer their C-terminal toxin domains into susceptible target cells upon binding to specific receptors. CDI+ cells also produce immunity proteins that neutralize the toxin domains delivered from neighboring siblings. Here, we show that CdiAEC536 from uropathogenic Escherichia coli 536 (EC536) uses OmpC and OmpF as receptors to recognize target bacteria. E. coli mutants lacking either ompF or ompC are resistant to CDIEC536-mediated growth inhibition, and both porins are required for target-cell adhesion to inhibitors that express CdiAEC536. Experiments with single-chain OmpF fusions indicate that the CdiAEC536 receptor is heterotrimeric OmpC-OmpF. Because the OmpC and OmpF porins are under selective pressure from bacteriophages and host immune systems, their surface-exposed loops vary between E. coli isolates. OmpC polymorphism has a significant impact on CDIEC536 mediated competition, with many E. coli isolates expressing alleles that are not recognized by CdiAEC536. Analyses of recombinant OmpC chimeras suggest that extracellular loops L4 and L5 are important recognition epitopes for CdiAEC536. Loops L4 and L5 also account for much of the sequence variability between E. coli OmpC proteins, raising the possibility that CDI contributes to the selective pressure driving OmpC diversification. We find that the most efficient CdiAEC536 receptors are encoded by isolates that carry the same cdi gene cluster as E. coli 536. Thus, it appears that CdiA effectors often bind preferentially to "self" receptors, thereby promoting interactions between sibling cells. As a consequence, these effector proteins cannot recognize nor suppress the growth of many potential competitors. These findings suggest that self-recognition and kin selection are important functions of CDI. PMID:27723824

  2. Identification of a de novo variant in CHUK in a patient with an EEC/AEC syndrome-like phenotype and hypogammaglobulinemia.

    PubMed

    Khandelwal, Kriti D; Ockeloen, Charlotte W; Venselaar, Hanka; Boulanger, Cécile; Brichard, Bénédicte; Sokal, Etienne; Pfundt, Rolph; Rinne, Tuula; van Beusekom, Ellen; Bloemen, Marjon; Vriend, Gerrit; Revencu, Nicole; Carels, Carine E L; van Bokhoven, Hans; Zhou, Huiqing

    2017-05-17

    The cardinal features of Ectrodactyly, Ectodermal dysplasia, Cleft lip/palate (EEC), and Ankyloblepharon-Ectodermal defects-Cleft lip/palate (AEC) syndromes are ectodermal dysplasia (ED), orofacial clefting, and limb anomalies. EEC and AEC are caused by heterozygous mutations in the transcription factor p63 encoded by TP63. Here, we report a patient with an EEC/AEC syndrome-like phenotype, including ankyloblepharon, ED, cleft palate, ectrodactyly, syndactyly, additional hypogammaglobulinemia, and growth delay. Neither pathogenic mutations in TP63 nor CNVs at the TP63 locus were identified. Exome sequencing revealed de novo heterozygous variants in CHUK (conserved helix-loop-helix ubiquitous kinase), PTGER4, and IFIT2. While the variant in PTGER4 might contribute to the immunodeficiency and growth delay, the variant in CHUK appeared to be most relevant for the EEC/AEC-like phenotype. CHUK is a direct target gene of p63 and encodes a component of the IKK complex that plays a key role in NF-κB pathway activation. The identified CHUK variant (g.101980394T>C; c.425A>G; p.His142Arg) is located in the kinase domain which is responsible for the phosphorylation activity of the protein. The variant may affect CHUK function and thus contribute to the disease phenotype in three ways: (1) the variant exhibits a dominant negative effect and results in an inactive IKK complex that affects the canonical NF-κB pathway; (2) it affects the feedback loop of the canonical and non-canonical NF-κB pathways that are CHUK kinase activity-dependent; and (3) it disrupts NF-κB independent epidermal development that is often p63-dependent. Therefore, we propose that the heterozygous CHUK variant is highly likely to be causative to the EEC/AEC-like and additional hypogammaglobulinemia phenotypes in the patient presented here. © 2017 Wiley Periodicals, Inc.

  3. Development of an imaging-planning program for screen/film and computed radiography mammography for breasts with short chest wall to nipple distance.

    PubMed

    Dong, S L; Su, J L; Yeh, Y H; Chu, T C; Lin, Y C; Chuang, K S

    2011-04-01

    Imaging breasts with a short chest wall to nipple distance (CWND) using a traditional mammographic X-ray unit is a technical challenge for mammographers. The purpose of this study is the development of an imaging-planning program to assist in determination of imaging parameters of screen/film (SF) and computed radiography (CR) mammography for short CWND breasts. A traditional mammographic X-ray unit (Mammomat 3000, Siemens, Munich, Germany) was employed. The imaging-planning program was developed by combining the compressed breast thickness correction, the equivalent polymethylmethacrylate thickness assessment for breasts and the tube loading (mAs) measurement. Both phantom exposures and a total of 597 exposures were used for examining the imaging-planning program. Results of the phantom study show that the tube loading rapidly decreased with the CWND when the automatic exposure control (AEC) detector was not fully covered by the phantom. For patient exposures with the AEC fully covered by breast tissue, the average fractional tube loadings, defined as the ratio of the predicted mAs using the imaging-planning program and mAs of the mammogram, were 1.10 and 1.07 for SF and CR mammograms, respectively. The predicted mAs values were comparable to the mAs values, as determined by the AEC. By applying the imaging-planning program in clinical practice, the experiential dependence of the mammographer for determination of the imaging parameters for short CWND breasts is minimised.

  4. Advances in Enterprise Control. AEC Proceedings, November 15-16, 1999/San Diego, California

    DTIC Science & Technology

    1999-11-16

    structure of tropical termite mounds. 2.3. Mechanisms that each agent deposits one unit of pheromone per unit time and that a proportion 0 < E < 1 of the...Stubberud 137 Section 4: Distributed and Agent-Based Strategies 149 Synthetic Pheromones for Distributed Motion Control by H. Van Dyke Parunak and...Computer Engineering, June, 1994. 147 148 Section 4 Distributed and Agent-Based Strategies 149 150 Synthetic Pheromones for Distributed Motion

  5. Growth, nutritional, and gastrointestinal aspects of ankyloblepharon-ectodermal defect-cleft lip and/or palate (AEC) syndrome

    USDA-ARS?s Scientific Manuscript database

    Ankyloblepharon-ectodermal defect-cleft lip and/or palate (AEC), is a rare genetic disorder due to mutations in the TP63 gene. In the present study, we characterized the pattern of growth and body composition, and the nutritional and gastrointestinal aspects of children and adults (n = 18) affected ...

  6. NEPP Evaluation of Automotive Grade Tantalum Chip Capacitors

    NASA Technical Reports Server (NTRS)

    Sampson, Mike; Brusse, Jay

    2018-01-01

    Automotive grade tantalum (Ta) chip capacitors are available at lower cost with smaller physical size and higher volumetric efficiency compared to military/space grade capacitors. Designers of high reliability aerospace and military systems would like to take advantage of these attributes while maintaining the high standards for long-term reliable operation they are accustomed to when selecting military-qualified established reliability tantalum chip capacitors (e.g., MIL-PRF-55365). The objective for this evaluation was to assess the long-term performance of off-the-shelf automotive grade Ta chip capacitors (i.e., manufacturer self-qualified per AEC Q-200). Two (2) lots of case size D manganese dioxide (MnO2) cathode Ta chip capacitors from 1 manufacturer were evaluated. The evaluation consisted of construction analysis, basic electrical parameter characterization, extended long-term (2000 hours) life testing and some accelerated stress testing. Tests and acceptance criteria were based upon manufacturer datasheets and the Automotive Electronics Council's AEC Q-200 qualification specification for passive electronic components. As-received a few capacitors were marginally above the specified tolerance for capacitance and ESR. X-ray inspection found that the anodes for some devices may not be properly aligned within the molded encapsulation leaving less than 1 mil thickness of the encapsulation. This evaluation found that the long-term life performance of automotive grade Ta chip capacitors is generally within specification limits suggesting these capacitors may be suitable for some space applications.

  7. Dose inspection and risk assessment on radiation safety for the use of non-medical X-ray machines in Taiwan

    NASA Astrophysics Data System (ADS)

    Hsu, Fang-Yuh; Hsu, Shih-Ming; Chao, Jiunn-Hsing

    2017-11-01

    The subject of this study is the on-site visits and inspections of facilities commissioned by the Atomic Energy Council (AEC) in Taiwan. This research was conducted to evaluate the possible dose and dose rate of cabinet-type X-ray equipment with nominal voltages of 30-150 kV and open-beam (portable or handheld) equipment, taking both normal operation and possibly abnormal operation conditions into account. Doses and dose rates were measured using a plastic scintillation survey meter and an electronic personal dosimeter. In total, 401 X-ray machines were inspected, including 139 units with nominal voltages of 30-50 kV X-ray equipment, 140 units with nominal voltages of 50-150 kV, and 122 open-beam (portable or handheld) X-ray equipment. The investigated doses for radiation workers and non-radiation workers operating cabinet-type X-ray equipment under normal safety conditions were all at the background dose level. Several investigated dose rates at the position of 10 cm away from the surface of open-beam (portable or handheld) X-ray equipment were very high, such X-ray machines are used by aeronautical police for the detection of suspected explosives, radiation workers are far away (at least 10 m away) from the X-ray machine during its operation. The doses per operation in X-ray equipment with a 30-50 kV nominal voltage were less than 1 mSv in all cases of abnormal use. Some doses were higher than 1 mSv per operation for X-ray equipment of 50-150 kV nominal voltage X-ray. The maximum dose rates at the beam exit have a very wide range, mostly less than 100 μSv/s and the largest value is about 3.92 mSv/s for open-beam (portable or handheld) X-ray devices. The risk induced by operating X-ray devices with nominal voltages of 30-50 kV is extremely low. The 11.5 mSv dose due to one operation at nominal voltage of 50-150 kV X-ray device is equivalent to the exposure of taking 575 chest X-rays. In the abnormal use of open-beam (portable or handheld) X-ray equipment, the effective dose of 3.92 mSv/s is equivalent to taking 196 chest radiographs within 1 s. This work assessed the annual doses (equivalent and effective doses) and risks of X-ray operator staff as reasonably as possible. The results of this research are helpful to the AEC (competent authority of ionization radiation) to improve the management and perform the safe control of X-ray equipment.

  8. Closed Loop Control Compact Exercise Device for Use on MPCV

    NASA Technical Reports Server (NTRS)

    Sheehan, Chris; Funk, Justin; Funk, Nathan; Kutnick, Gilead; Humphreys, Brad; Bruinsma, Douwe; Perusek, Gail

    2016-01-01

    Long duration space travel to Mars or to an asteroid will expose astronauts to extended periods of reduced gravity. To combat spaceflight physiological deconditioning, astronauts will use resistive and aerobic exercise regimens for the duration of the space flight to minimize the loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the mass and volume available for an exercise device in the next generation of spacecraft is limited. Therefore, compact exercise device prototypes are being developed for human in the loop evaluations. The NASA Human Research Program (HRP) is managing Advanced Exercise Concepts (AEC) requirements development and candidate technology maturation for all exploration mission profiles from Multi-Purpose Crew Vehicle (MPCV) exploration missions (e.g., EM-2, up to 21 day) to Mars Transit (up to 1000 day) missions. Numerous technologies have been considered and evaluated against HRP-approved functional requirements and include flywheel, pneumatic and closed-loop microprocessor-controlled motor driven power plants. Motor driven technologies offer excellent torque density and load accuracy characteristics as well as the ability to create custom mechanical impedance (the dynamic relationship between force and velocity) and custom load versus position exercise algorithms. Further, closed-loop motor-driven technologies offer the ability to monitor exercise dose parameters and adapt to the needs of the crewmember for real time optimization of exercise prescriptions. A simple proportional-integral-derivative (PID) controller is demonstrated in a prototype motor driven exercise device with comparison to resistive static and dynamic load set points and aerobic work rate targets. The resistive load term in the algorithm includes a constant force component (Fcmg) as well as inertial component (Fima) and a discussion of system tuning is presented in terms of addressing key functional requirements and human interfaces. The device aerobic modality is modelled as a rowing exercise using ground data sets obtained from Concept 2 rowers as well as competitive rowing1. A discussion of software and electronic implementations are presented which demonstrate unique approaches to meeting the constrained mass, volume and power requirements of the MPCV. . In addition to utilizing traditional PID control, controllers utilizing state feedback with gains solved using a Linear Quadratic Regulator will be developed. Controllability and observability will be utilized to investigate the need for state measurement in the design. As the control system directly interacts with human test subjects, robust methods such as H-infinity are also being investigated.1. Kleshnev V. Biomechanics. In: Rowing, Handbook of Sports Medicine and Science. ed. by Secher N., Voliantis S. IOC Medical Commission, Blackwell Pub. pp. 22-34, 2007

  9. SHEET PLASMA DEVICE

    DOEpatents

    Henderson, O.A.

    1962-07-17

    An ion-electron plasma heating apparatus of the pinch tube class was developed wherein a plasma is formed by an intense arc discharge through a gas and is radially constricted by the magnetic field of the discharge. To avoid kink and interchange instabilities which can disrupt a conventional arc shortiy after it is formed, the apparatus is a pinch tube with a flat configuration for forming a sheet of plasma between two conductive plates disposed parallel and adjacent to the plasma sheet. Kink instabilities are suppressed by image currents induced in the conductive plates while the interchange instabilities are neutrally stable because of the flat plasma configuration wherein such instabilities may occur but do not dynamically increase in amplitude. (AEC)

  10. PLASMA GENERATOR

    DOEpatents

    Wilcox, J.M.; Baker, W.R.

    1963-09-17

    This invention is a magnetohydrodynamic device for generating a highly ionized ion-electron plasma at a region remote from electrodes and structural members, thus avoiding contamination of the plasma. The apparatus utilizes a closed, gas-filled, cylindrical housing in which an axially directed magnetic field is provided. At one end of the housing, a short cylindrical electrode is disposed coaxially around a short axial inner electrode. A radial electrical discharge is caused to occur between the inner and outer electrodes, creating a rotating hydromagnetic ionization wave that propagates aiong the magnetic field lines toward the opposite end of the housing. A shorting switch connected between the electrodes prevents the wave from striking the opposite end of the housing. (AEC)

  11. CFTR is required for maximal transepithelial liquid transport in pig alveolar epithelia.

    PubMed

    Li, Xiaopeng; Comellas, Alejandro P; Karp, Philip H; Ernst, Sarah E; Moninger, Thomas O; Gansemer, Nicholas D; Taft, Peter J; Pezzulo, Alejandro A; Rector, Michael V; Rossen, Nathan; Stoltz, David A; McCray, Paul B; Welsh, Michael J; Zabner, Joseph

    2012-07-01

    A balance between alveolar liquid absorption and secretion is critical for maintaining optimal alveolar subphase liquid height and facilitating gas exchange in the alveolar space. However, the role of cystic fibrosis transmembrane regulator protein (CFTR) in this homeostatic process has remained elusive. Using a newly developed porcine model of cystic fibrosis, in which CFTR is absent, we investigated ion transport properties and alveolar liquid transport in isolated type II alveolar epithelial cells (T2AECs) cultured at the air-liquid interface. CFTR was distributed exclusively to the apical surface of cultured T2AECs. Alveolar epithelia from CFTR(-/-) pigs failed to increase liquid absorption in response to agents that increase cAMP, whereas cAMP-stimulated liquid absorption in CFTR(+/-) epithelia was similar to that in CFTR(+/+) epithelia. Expression of recombinant CFTR restored stimulated liquid absorption in CFTR(-/-) T2AECs but had no effect on CFTR(+/+) epithelia. In ex vivo studies of nonperfused lungs, stimulated liquid absorption was defective in CFTR(-/-) alveolar epithelia but similar between CFTR(+/+) and CFTR(+/-) epithelia. When epithelia were studied at the air-liquid interface, elevating cAMP levels increased subphase liquid height in CFTR(+/+) but not in CFTR(-/-) T2AECs. Our findings demonstrate that CFTR is required for maximal liquid absorption under cAMP stimulation, but it is not the rate-limiting factor. Furthermore, our data define a role for CFTR in liquid secretion by T2AECs. These insights may help to develop new treatment strategies for pulmonary edema and respiratory distress syndrome, diseases in which lung liquid transport is disrupted.

  12. The Role of English Debating Tournament in the Face of the ASEAN Economy Community (AEC)

    ERIC Educational Resources Information Center

    Husnawadi; Syamsudarni

    2016-01-01

    Since its establishment in the late 2015, the ASEAN Economic Community (AEC) with English as the official language has forced its participating countries to improve the quality of English language teaching, in the hope to prepare their people to be globally competitive, as the lack of English proficiency remains the main challenge across the…

  13. An improved method for the isolation of rat alveolar type II lung cells: Use in the Comet assay to determine DNA damage induced by cigarette smoke.

    PubMed

    Dalrymple, Annette; Ordoñez, Patricia; Thorne, David; Dillon, Debbie; Meredith, Clive

    2015-06-01

    Smoking is a cause of serious diseases, including lung cancer, emphysema, chronic bronchitis and heart disease. DNA damage is thought to be one of the mechanisms by which cigarette smoke (CS) initiates disease in the lung. Indeed, CS induced DNA damage can be measured in vitro and in vivo. The potential of the Comet assay to measure DNA damage in isolated rat lung alveolar type II epithelial cells (AEC II) was explored as a means to include a genotoxicity end-point in rodent sub-chronic inhalation studies. In this study, published AEC II isolation methods were improved to yield viable cells suitable for use in the Comet assay. The improved method reduced the level of basal DNA damage and DNA repair in isolated AEC II. CS induced DNA damage could also be quantified in isolated cells following a single or 5 days CS exposure. In conclusion, the Comet assay has the potential to determine CS or other aerosol induced DNA damage in AEC II isolated from rodents used in sub-chronic inhalation studies. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  14. Genetically-modified pig mesenchymal stromal cells: xenoantigenicity and effect on human T-cell xenoresponses.

    PubMed

    Ezzelarab, Mohamed; Ezzelarab, Corin; Wilhite, Tyler; Kumar, Goutham; Hara, Hidetaka; Ayares, David; Cooper, David K C

    2011-01-01

    Mesenchymal stromal cells (MSC) are being investigated as immunomodulatory therapy in the field of transplantation, particularly islet transplantation. While MSC can regenerate across species barriers, the immunoregulatory influence of genetically modified pig MSC (pMSC) on the human and non-human primate T-cell responses has not been studied. Mesenchymal stromal cells from wild-type (WT), α1,3-galactosyltransferase gene knockout (GTKO) and GTKO pigs transgenic for the human complement-regulatory protein CD46 (GTKO/CD46) were isolated and tested for differentiation. Antibody binding and T-cell responses to WT and GTKO pMSC in comparison with GTKO pig aortic endothelial cells (pAEC) were investigated. The expression of swine leukocyte antigen (SLA) class II (SLA II) was tested. Costimulatory molecules CD80 and CD86 mRNA levels were measured. Human T-cell proliferation and the production of pro-inflammatory cytokines in response to GTKO and GTKO/CD46 pMSC in comparison with human MSC (hMSC) were evaluated. α1,3-galactosyltransferase gene knockout and GTKO/CD46 pMSC isolation and differentiation were achieved in vitro. Binding of human antibodies and T-cell responses were lower to GTKO than those to WT pMSC. Human and baboon (naïve and sensitized) antibody binding were significantly lower to GTKO pMSC than to GTKO pAEC. Before activation, <1% of GTKO pMSC expressed SLA II, compared with 2.5% of GTKO pAEC. After pig interferon-gamma (pIFN-γ) activation, 99% of GTKO pAEC upregulated SLA II expression, compared with 49% of GTKO pMSC. Only 3% of GTKO pMSC expressed CD80 compared with 80% of GTKO pAEC without activation. After pIFN-γ activation, GTKO pAEC upregulated CD86 mRNA level stronger than GTKO pMSC. The human CD4(+) T-cell response to GTKO pMSC was significantly weaker than that to GTKO pAEC, even after pIFN-γ activation. More than 99% of GTKO/CD46 pMSC expressed hCD46. Human peripheral blood mononuclear cells and CD4(+) T-cell responses to GTKO and GTKO/CD46 pMSC were comparable with those to hMSC, and all were significantly lower than to GTKO pAEC. GTKO/CD46 pMSC downregulated human T-cell proliferation as efficiently as hMSC. The level of proinflammatory cytokines IL-2, IFN-γ, TNF-α, and sCD40L correlated with the downregulation of T-cell proliferation by all types of MSC. Genetically modified pMSC is significantly less immunogenic than WT pMSC. GTKO/CD46 pMSC downregulates the human T-cell responses to pig antigens as efficiently as human MSC, which can be advantageous for therapeutic cell xenotransplantation. © 2011 John Wiley & Sons A/S.

  15. Human amniotic epithelial cells inhibit CD4+ T cell activation in acute kidney injury patients by influencing the miR-101-c-Rel-IL-2 pathway.

    PubMed

    Liu, Junfeng; Hua, Rong; Gong, Zhangbin; Shang, Bin; Huang, Yongyi; Guo, Lihe; Liu, Te; Xue, Jun

    2017-01-01

    In the pathogenesis of acute kidney injury (AKI), the release of multiple interleukins can lead to increased kidney damage. Human amniotic epithelial cells (HuAECs) can inhibit immune cell activation in vivo and in vitro. We hypothesized that HuAECs could weaken patient-derived peripheral blood CD4+ T-cell activation and decreasing the ability of these cells to express and release IL-2. -Cell proliferation assay revealed that under the same culture conditions, activated AKI patient-derived CD4+ T cells had a significantly reduced proliferation rate when were co-cultured with HuAECs. And the level of IL-2 released was also significantly reduced. Western blot and qRT-PCR assays showed that the expression of c-Rel in the CD4+ T cells was also significantly reduced. However, the expression level of endogenous miR-101 in the CD4+ T cells co-cultured with HuAECs was significantly increased. Luciferase reporter assay results suggested that miR-101 could bind to a specific site in the c-Rel 3' UTR and induce the post-transcriptional silencing of c-Rel. Subsequently, we over-expressed miR-101 in AKI patient-derived CD4+ T cells. The qRT-PCR and western blot assay results revealed that the expression of endogenous c-Rel was significantly reduced, while the ELISA results indicated that the level of IL-2 released was also significantly decreased. Finally, ChIP-PCR assay results showed that the miR-101-overexpressing CD4+ T-cell group and the HuAEC co-culture CD4+ T-cell group exhibited significantly decreased binding capacities between the 'c-Rel-NFκB' complex and the IL-2 gene promoter, and the transcriptional activity of IL-2 was also significantly decreased. Therefore, we confirmed that HuAECs can stimulate miR-101 expression in AKI patient-derived peripheral blood CD4+ T cells, thus inhibiting the expression of the miR-101 target gene c-Rel and leading to a reduction in IL-2 expression and release. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. The Adaptive Ecosystem Climatology (AEC): Design and Development

    NASA Astrophysics Data System (ADS)

    deRada, S.; Penta, B.; McCarthy, S.; Gould, R. W., Jr.

    2016-02-01

    The concept of ecosystem-based management (EBM), recently introduced to rectify the shortcomings of single-species management policies, has been widely accepted as a basis for the conservation and management of natural resources. In line with NOAA's Integrated Ecosystem Assessment (IEA) Program, EBM is an integrated approach that considers the entire ecosystem and the interactions among species rather than focusing on individual components. This integrative approach relies on heterogeneous data, physical as well as biogeochemical data, among many others. Relative to physical data, however, marine biogeochemical records, also critical in IEA and EBM, are still lacking, both in terms of mature models and in terms of observational data availability. TheAdaptive Ecosystem Climatology (AEC) was conceived as a novel approach to address these limitations, mitigating the shortcomings of the individual components and combining their strengths to enhance decision-making activities. AEC is designed on the concept that a high-frequency climatology can be used as a baseline into which available observational data can be ingested to produce a higher accuracy product. In the absence of observations, the climatology acts as a best estimate. AEC was developed using a long-term simulation of a coupled biophysical numerical model configured for the Gulf of Mexico. Using the model results, we constructed a three-dimensional, dynamically balanced, gridded, static climatology for each calendar day. Using this `static' climatology as a background `first guess', observations from a particular date are ingested via optimal interpolation to `nudge' the climatology toward current conditions, thus providing representative fields for that date (adaptive climatology). With this adaptive approach, AEC can support a variety of EBM objectives, from fisheries, to resource management, to coastal resilience.

  17. Patterns, evolution, and severity of striatal injury in insidious- versus acute-onset glutaric aciduria type 1.

    PubMed

    Boy, Nikolas; Garbade, Sven F; Heringer, Jana; Seitz, Angelika; Kölker, Stefan; Harting, Inga

    2018-05-02

    Striatal injury in patients with glutaric aciduria type 1 (GA1) results in a complex, predominantly dystonic, movement disorder. Onset may be acute following acute encephalopathic crisis (AEC) or insidious without apparent acute event. We analyzed clinical and striatal magnetic resonance imaging (MRI) findings in 21 symptomatic GA1 patients to investigate if insidious- and acute-onset patients differed in timing, pattern of striatal injury, and outcome. Eleven patients had acute and ten had insidious onset, two with later AEC (acute-on-insidious). The median onset of dystonia was 10 months in both groups, and severity was greater in patients after AEC (n = 8 severe, n = 5 moderate) than in insidious onset (n = 4 mild, n = 3 moderate, n = 1 severe). Deviations from guideline-recommended basic metabolic treatment were identified in six insidious-onset patients. Striatal lesions were extensive in all acute-onset patients and restricted to the dorsolateral putamen in eight of ten insidious-onset patients. After AEC, the two acute-on-insidious patients had extensive striatal changes superimposed on pre-existing dorsolateral putaminal lesions. Two insidious-onset patients with progressive dystonia without overt AEC also had extensive striatal changes, one with sequential striatal injury revealed by diffusion-weighted imaging. Insidious-onset patients had a latency phase of 3.5 months to 6.5 years between detection and clinical manifestation of dorsolateral putaminal lesions. Insidious-onset type GA1 is characterized by dorsolateral putaminal lesions, less severe dystonia, and an asymptomatic latency phase, despite already existing lesions. Initially normal MRI during the first months and deviations from guideline-recommended treatment in a large proportion of insidious-onset patients substantiate the protective effect of neonatally initiated treatment.

  18. Formerly utilized MED/AEC sites remedial action program. Radiological survey of The George Herbert Jones Chemical Laboratory, The University of Chicago, Chicago, Illinois, June 13-17, 1977

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wynveen, R.A.; Smith, W.H.; Mayes, C.B.

    A comprehensive radiological survey was conducted at George Herbert Jones Chemical Laboratory at the University of Chicago, Chicago, Illinois. Radiochemistry for the MED/AEC project was performed in this building in the 1940s. The building is now used as laboratories, offices, and classrooms. The survey was undertaken to determine the location and quantities of any radioactive materials remaining from the MED/AEC operations. Forty-three spots of contamination possibly resulting from MED/AEC occupancy in 17 rooms exceeded the allowable limits as given in the ANSI Standard N13.12. Under current use conditions, the potential for radiation exposure to occupants of this building from thesemore » sources of contamination is remote. Concentrations of radon daughters in the air of the building, as measured with grab-sampling techniques, were below the limit of 0.01 WL above background as given in the Surgeon General's Guidelines. No long-lived radionuclides were detected in any air sample. Concentrations of radionuclides in soil samples from near the laboratory generally indicated background levels. In order to reduce the potential for radiation exposure, remedial measures such as stabilization of the contamination in place would be applicable as a short-term measure. In order to reduce the risk in the event that building modifications take place in the future, health physics procedures and coverage are recommended. The long-term solution would involve decontamination by removal of the radioactive residues from the 17 rooms or areas where contamination possibly resulting from MED/AEC activities was detected.« less

  19. Liver‐Directed Human Amniotic Epithelial Cell Transplantation Improves Systemic Disease Phenotype in Hurler Syndrome Mouse Model

    PubMed Central

    Rodriguez, Natalie S.; Yanuaria, Lisa; Parducho, Kevin Murphy R.; Garcia, Irving M.; Varghese, Bino A.; Grubbs, Brendan H.

    2017-01-01

    Abstract Mucopolysaccharidosis type 1 (MPS1) is an inherited lysosomal storage disorder caused by a deficiency in the glycosaminoglycan (GAG)‐degrading enzyme α‐l‐iduronidase (IDUA). In affected patients, the systemic accumulation of GAGs results in skeletal dysplasia, neurological degeneration, multiple organ dysfunction, and early death. Current therapies, including enzyme replacement and bone marrow transplant, improve life expectancy but the benefits to skeletal and neurological phenotypes are limited. In this study, we tested the therapeutic efficacy of liver‐directed transplantation of a placental stem cell, which possesses multilineage differentiation potential, low immunogenicity, and high lysosomal enzyme activity. Unfractionated human amniotic epithelial cells (hAECs) were transplanted directly into the liver of immunodeficient Idua knockout mouse neonates. The hAECs engraftment was immunohistochemically confirmed with anti‐human mitochondria staining. Enzyme activity assays indicated that hAECs transplantation restored IDUA function in the liver and significantly decreased urinary GAG excretion. Histochemical and micro‐computed tomography analyses revealed reduced GAG deposition in the phalanges joints and composition/morphology improvement of cranial and facial bones. Neurological assessment in the hAEC treated mice showed significant improvement of sensorimotor coordination in the hAEC treated mice compared to untreated mice. Results confirm that partial liver cell replacement with placental stem cells can provide long‐term (>20 weeks) and systemic restoration of enzyme function, and lead to significant phenotypic improvement in the MPS1 mouse model. This preclinical data indicate that liver‐directed placental stem cell transplantation may improve skeletal and neurological phenotypes of MPS1 patients. Stem Cells Translational Medicine 2017;6:1583–1594 PMID:28585336

  20. Liver-Directed Human Amniotic Epithelial Cell Transplantation Improves Systemic Disease Phenotype in Hurler Syndrome Mouse Model.

    PubMed

    Rodriguez, Natalie S; Yanuaria, Lisa; Parducho, Kevin Murphy R; Garcia, Irving M; Varghese, Bino A; Grubbs, Brendan H; Miki, Toshio

    2017-07-01

    Mucopolysaccharidosis type 1 (MPS1) is an inherited lysosomal storage disorder caused by a deficiency in the glycosaminoglycan (GAG)-degrading enzyme α-l-iduronidase (IDUA). In affected patients, the systemic accumulation of GAGs results in skeletal dysplasia, neurological degeneration, multiple organ dysfunction, and early death. Current therapies, including enzyme replacement and bone marrow transplant, improve life expectancy but the benefits to skeletal and neurological phenotypes are limited. In this study, we tested the therapeutic efficacy of liver-directed transplantation of a placental stem cell, which possesses multilineage differentiation potential, low immunogenicity, and high lysosomal enzyme activity. Unfractionated human amniotic epithelial cells (hAECs) were transplanted directly into the liver of immunodeficient Idua knockout mouse neonates. The hAECs engraftment was immunohistochemically confirmed with anti-human mitochondria staining. Enzyme activity assays indicated that hAECs transplantation restored IDUA function in the liver and significantly decreased urinary GAG excretion. Histochemical and micro-computed tomography analyses revealed reduced GAG deposition in the phalanges joints and composition/morphology improvement of cranial and facial bones. Neurological assessment in the hAEC treated mice showed significant improvement of sensorimotor coordination in the hAEC treated mice compared to untreated mice. Results confirm that partial liver cell replacement with placental stem cells can provide long-term (>20 weeks) and systemic restoration of enzyme function, and lead to significant phenotypic improvement in the MPS1 mouse model. This preclinical data indicate that liver-directed placental stem cell transplantation may improve skeletal and neurological phenotypes of MPS1 patients. Stem Cells Translational Medicine 2017;6:1583-1594. © 2017 The Authors Stem Cells Translational Medicine published by Wiley Periodicals, Inc. on behalf of AlphaMed Press.

  1. CRUCIFORM CONTROL ROD JOINT

    DOEpatents

    Thorp, A.G. II

    1962-08-01

    An invention is described which relates to nuclear reactor control rod components and more particularly to a joint between cruciform control rod members and cruciform control rod follower members. In one embodiment this invention provides interfitting crossed arms at adjacent ends of a control rod and its follower in abutting relation. This holds the members against relative opposite longitudinal movement while a compression member keys the arms against relative opposite rotation around a common axis. Means are also provided for centering the control rod and its follower on a common axis and for selectively releasing the control rod from its follower for the insertion of a replacement of the control rod and reuse of the follower. (AEC)

  2. The Balkanisation of Power in Australian Education: Political Lessons from the Recent Collapse of National Partnership in Policy Making.

    ERIC Educational Resources Information Center

    Macpherson, R. J. S.

    During the Perth meeting of the Australian Education Council (AEC) on July 1-2, 1993, policy making power shifted from the AEC to the states and from Labor to non-Labor ministers. Labor ministerial power directed public education through much of the 1980s, when the rhetoric of national partnership was all-pervasive. At the July conference, the…

  3. Agri-environmental collaboratives as bridging organisations in landscape management.

    PubMed

    Prager, Katrin

    2015-09-15

    In recent years, landscape and its management has become a focus of policies and academic conceptualisation. Landscape is understood as a concept of interconnected natural and human systems. Its management must take into account the dynamic interdependencies and diverging interests of various stakeholders at different levels. Bridging organisations can provide an arena for trust-building, conflict resolution, learning and collaboration between relevant stakeholders. This paper draws on two strands of literature - landscape governance and co-management of social-ecological systems - to investigate the contributions of agri-environmental collaboratives (AEC) to sustainable landscape management. Based on data from 41 interviews with key informants and AEC members in Germany and the Netherlands, six fields of contributions were identified: policy implementation and service provision; coordination and mediation; awareness raising and behaviour change; care for 'everyday' landscapes; maintenance and protection of landscapes (including species and habitats); and income generation and economic benefits. Some of the contributions evolve around the specific role of AEC as bridging organisations, but other contributions such as economic benefits emerge beyond this analytical lens. The paper therefore emphasises holistic, bottom up assessment of AEC contributions and argues that governments should support such organisations through i) funding for facilitators and ii) funding for impact monitoring and data management. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Bacillus anthracis spore movement does not require a carrier cell and is not affected by lethal toxin in human lung models.

    PubMed

    Booth, J Leland; Duggan, Elizabeth S; Patel, Vineet I; Langer, Marybeth; Wu, Wenxin; Braun, Armin; Coggeshall, K Mark; Metcalf, Jordan P

    2016-10-01

    The lung is the entry site for Bacillus anthracis in inhalation anthrax, the most deadly form of the disease. Spores escape from the alveolus to regional lymph nodes, germinate and enter the circulatory system to cause disease. The roles of carrier cells and the effects of B. anthracis toxins in this process are unclear. We used a human lung organ culture model to measure spore uptake by antigen presenting cells (APC) and alveolar epithelial cells (AEC), spore partitioning between these cells, and the effects of B. anthracis lethal toxin and protective antigen. We repeated the study in a human A549 alveolar epithelial cell model. Most spores remained unassociated with cells, but the majority of cell-associated spores were in AEC, not in APC. Spore movement was not dependent on internalization, although the location of internalized spores changed in both cell types. Spores also internalized in a non-uniform pattern. Toxins affected neither transit of the spores nor the partitioning of spores into AEC and APC. Our results support a model of spore escape from the alveolus that involves spore clustering with transient passage through intact AEC. However, subsequent transport of spores by APC from the lung to the lymph nodes may occur. Published by Elsevier Masson SAS.

  5. Amniotic Epithelial Cells: A New Tool to Combat Aging and Age-Related Diseases?

    PubMed Central

    Di Germanio, Clara; Bernier, Michel; de Cabo, Rafael; Barboni, Barbara

    2016-01-01

    The number of elderly people is growing at an unprecedented rate and this increase of the aging population is expected to have a direct impact on the incidence of age-related diseases and healthcare-associated costs. Thus, it is imperative that new tools are developed to fight and slow age-related diseases. Regenerative medicine is a promising strategy for the maintenance of health and function late in life; however, stem cell-based therapies face several challenges including rejection and tumor transformation. As an alternative, the placenta offers an extraordinary source of fetal stem cells, including the amniotic epithelial cells (AECs), which retain some of the characteristics of embryonic stem cells, but show low immunogenicity, together with immunomodulatory and anti-inflammatory activities. Because of these characteristics, AECs have been widely utilized in regenerative medicine. This perspective highlights different mechanisms triggered by transplanted AECs that could be potentially useful for anti-aging therapies, which include: Graft and differentiation for tissue regeneration in age-related settings, anti-inflammatory behavior to combat “inflammaging,” anti-tumor activity, direct lifespan and healthspan extension properties, and possibly rejuvenation in a manner reminiscent of heterochronic parabiosis. Here, we critically discuss benefits and limitation of AECs-based therapies in age-related diseases. PMID:27921031

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goodson, J.O.

    This is the first of three volumes which document the historical development of the first US compressed-air energy storage (CAES) Power-generation facility. Volume 1 is a background report and presents a chronicle of the development of the CAES facility from the early interest in CAES until inception of engineering/construction on August 11, 1988. The 110 MW - 26 hr CAES plant is owned and operated by Alabama Electric Cooperative, Inc. (AEC) of Andalusia, Alabama. The plant is the first CAES plant in the United States and the world`s first CAES facility incorporating a recuperator to improve efficiency. The plant suppliesmore » competitively priced peaking power to the AEC owner members. The economics of CAES-produced power is attractive because the energy-intensive air-compression mode is powered by relatively inexpensive base-load power external to the CAES plant. The compressed-air energy is stored underground until needed, and during the power-production mode, the only fuel required is that to heat the compressed air to expander-inlet temperature. The project development for AEC`s CAES plant involved much planning and preliminary design work. Specifically, this included load and generation-planning studies, power-supply selections, conceptual designs, project administration, air-storage cavern and turbomachinery specifications and design, contract requirements, environmental and licensing issues, and construction planning.« less

  7. Human Research Program Advanced Exercise Concepts (AEC) Overview

    NASA Technical Reports Server (NTRS)

    Perusek, Gail; Lewandowski, Beth; Nall, Marsha; Norsk, Peter; Linnehan, Rick; Baumann, David

    2015-01-01

    Exercise countermeasures provide benefits that are crucial for successful human spaceflight, to mitigate the spaceflight physiological deconditioning which occurs during exposure to microgravity. The NASA Human Research Program (HRP) within the Human Exploration and Operations Mission Directorate (HEOMD) is managing next generation Advanced Exercise Concepts (AEC) requirements development and candidate technology maturation to Technology Readiness Level (TRL) 7 (ground prototyping and flight demonstration) for all exploration mission profiles from Multi Purpose Crew Vehicle (MPCV) Exploration Missions (up to 21 day duration) to Mars Transit (up to 1000 day duration) missions. These validated and optimized exercise countermeasures systems will be provided to the ISS Program and MPCV Program for subsequent flight development and operations. The International Space Station (ISS) currently has three major pieces of operational exercise countermeasures hardware: the Advanced Resistive Exercise Device (ARED), the second-generation (T2) treadmill, and the cycle ergometer with vibration isolation system (CEVIS). This suite of exercise countermeasures hardware serves as a benchmark and is a vast improvement over previous generations of countermeasures hardware, providing both aerobic and resistive exercise for the crew. However, vehicle and resource constraints for future exploration missions beyond low Earth orbit will require that the exercise countermeasures hardware mass, volume, and power be minimized, while preserving the current ISS capabilities or even enhancing these exercise capabilities directed at mission specific physiological functional performance and medical standards requirements. Further, mission-specific considerations such as preservation of sensorimotor function, autonomous and adaptable operation, integration with medical data systems, rehabilitation, and in-flight monitoring and feedback are being developed for integration with the exercise countermeasures systems. Numerous technologies have been considered and evaluated against HRP-approved functional device requirements for these extreme mission profiles, and include wearable sensors, exoskeletons, flywheel, pneumatic, and closed-loop microprocessor controlled motor driven systems. Each technology has unique advantages and disadvantages. The Advanced Exercise Concepts project oversees development of candidate next generation exercise countermeasures hardware, performs trade studies of current and state of the art exercise technologies, manages and supports candidate systems physiological evaluations with human test subjects on the ground, in flight analogs and flight. The near term goal is evaluation of candidate systems in flight, culminating in an integrated candidate next generation exercise countermeasures suite on the ISS which coalesces research findings from HRP disciplines in the areas of exercise performance for muscle, bone, cardiovascular, sensorimotor, behavioral health, and nutrition for optimal benefit to the crew.

  8. NEUTRON SOURCE USING MAGNETIC COMPRESSION OF PLASMA

    DOEpatents

    Quinn, W.E.; Elmore, W.C.; Little, E.M.; Boyer, K.; Tuck, J.L.

    1961-10-31

    A fusion reactor is described that utilizes compression and heating of an ionized thermonuclear fuel by an externally applied magnetic field, thus avoiding reliance on the pinch effect and its associated instability problems. The device consists of a gas-confining ceramic container surrounded by a single circumferential coil having a shape such as to produce a magnetic mirror geometry. A sinusoidally-oscillating, exponentially-damped current is passed circumferentially around the container, through the coil, inducing a circumferential current in the gas. Maximum compression and plasma temperature are obtained at the peak of the current oscillations, coinciding with maximum magnetic field intensity. Enhanced temperatures are obtained in the second and succeeding half cycles because the thermal energy accumulates from one half cycle to the next. (AEC)

  9. BOILING SLURRY REACTOR AND METHOD FO CONTROL

    DOEpatents

    Petrick, M.; Marchaterre, J.F.

    1963-05-01

    The control of a boiling slurry nuclear reactor is described. The reactor consists of a vertical tube having an enlarged portion, a steam drum at the top of the vertical tube, and at least one downcomer connecting the steam drum and the bottom of the vertical tube, the reactor being filled with a slurry of fissionabie material in water of such concentration that the enlarged portion of the vertical tube contains a critical mass. The slurry boils in the vertical tube and circulates upwardly therein and downwardly in the downcomer. To control the reactor by controlling the circulation of the slurry, a gas is introduced into the downcomer. (AEC)

  10. SYNCHROTRON RADIO FREQUENCY PHASE CONTROL SYSTEM

    DOEpatents

    Plotkin, M.; Raka, E.C.; Snyder, H.S.

    1963-05-01

    A system for canceling varying phase changes introduced by connecting cables and control equipment in an alternating gradient synchrotron is presented. In a specific synchrotron embodiment twelve spaced accelerating stations for the proton bunches are utilized. In order to ensure that the protons receive their boost or kick at the exact instant necessary it is necessary to compensate for phase changes occurring in the r-f circuitry over the wide range of frequencies dictated by the accelerated velocities of the proton bunches. A constant beat frequency is utilized to transfer the r-f control signals through the cables and control equipment to render the phase shift constant and readily compensable. (AEC)

  11. Increasing Responsiveness of the Army Rapid Acquisition Process: The Army Rapid Equipping Force

    DTIC Science & Technology

    2011-06-01

    System Increment 2 (JNBCRS2) Joint Urgent Operational Needs (JUON) effort. These interviews played a critical role in providing information on the...Operational Assessment. 91 Interview by the authors with JNBCRS2 ATEC System Team: Mr. Dough Cunningham, DTC, and Ms. Emily Yost, AEC, Aberdeen...Mr. Dough Cunningham, DTC, and Ms. Emily Yost, AEC, Aberdeen Proving Ground, MD, October 2010. 110 Major Scott Schroer, JNBCRS2 Team Lead, and the

  12. Information Management for Installation Restoration with Focus on Aberdeen Proving Ground, Maryland

    DTIC Science & Technology

    1993-08-01

    savings. Edgewood Area Project Background EA has been the site of extensive military munitions testing and disposal for over 70 years. Onsite burial of...titled "Installation Restoration Data Manage- ment Information System" (IRDMIS). This program, begun in 1975, has undergone several updates as technology ...collocated with AEC on EA, Maryland. Data from geotechnical chemical analysis and field survey results are supplied by AEC-authorized contractors and

  13. Enhanced hepatic differentiation of human amniotic epithelial cells on polyethylene glycol-linked multiwalled carbon nanotube-coated hydrogels.

    PubMed

    Zhao, Chunyan; Lin, Jamie Siqi; Choolani, Mahesh; Dan, Yock Young; Pastorin, Giorgia; Ho, Han Kiat

    2018-04-26

    Polyethylene glycol-linked multiwalled carbon nanotube-coated poly-acrylamide hydrogel (CNT-PA) was customized to mimic human liver stiffness and nanostructured surface in liver cells for modulating differentiation of human amniotic epithelial cells (hAECs) into functional hepatocyte-like cells (HLCs) in vitro. This composite of CNT-PA matrix enhanced the hepatic differentiation of hAECs into HLCs with suppression of pluripotent markers and up-regulation of hepatic markers at both transcript and protein levels. Furthermore, the HLCs on CNT-PA demonstrated hepatocytic functions in terms of albumin secretion, higher uptake of indocyanine green, and comparable CYP3A4 enzymatic function and inducibility when matched against HepG2 cells. Taken together, CNT-PA provides an efficient and scalable platform for the expansion of HLCs from hAECs and could be explored further for downstream development. Copyright © 2018 John Wiley & Sons, Ltd.

  14. Solid oxide fuel cell with multi-unit construction and prismatic design

    DOEpatents

    McPheeters, Charles C.; Dees, Dennis W.; Myles, Kevin M.

    1999-01-01

    A single cell unit of a solid oxide fuel cell that is individually fabricated and sintered prior to being connected to adjacent cells to form a solid oxide fuel cell. The single cell unit is comprised of a shaped anode sheet positioned between a flat anode sheet and an anode-electrolyte-cathode (A/E/C) sheet, and a shaped cathode sheet positioned between the A/E/C sheet and a cathode-interconnect-anode (C/I/A) sheet. An alternate embodiment comprises a shaped cathode sheet positioned between an A/E/C sheet and a C/I/A sheet. The shaped sheets form channels for conducting reactant gases. Each single cell unit is individually sintered to form a finished sub-assembly. The finished sub-assemblies are connected in electrical series by interposing connective material between the end surfaces of adjacent cells, whereby individual cells may be inspected for defects and interchanged with non-defective single cell units.

  15. Candidate chromosome 1 disease susceptibility genes for Sjogren’s syndrome xerostomia are narrowed by novel NOD.B10 congenic mice

    PubMed Central

    Mongini, Patricia K. A.; Kramer, Jill M.; Ishikawa, Tomo-o; Herschman, Harvey; Esposito, Donna

    2014-01-01

    Sjogren’s syndrome (SS) is characterized by salivary gland leukocytic infiltrates and impaired salivation (xerostomia). Cox-2 (Ptgs2) is located on chromosome 1 within the span of the Aec2 region. In an attempt to demonstrate that COX-2 drives antibody-dependent hyposalivation, NOD.B10 congenic mice bearing a Cox-2flox gene were generated. A congenic line with non-NOD alleles in Cox-2-flanking genes failed manifest xerostomia. Further backcrossing yielded disease-susceptible NOD.B10 Cox-2flox lines; fine genetic mapping determined that critical Aec2 genes lie within a 1.56 to 2.17 Mb span of DNA downstream of Cox-2. Bioinformatics analysis revealed that susceptible and non-susceptible lines exhibit non-synonymous coding SNPs in 8 protein-encoding genes of this region, thereby better delineating candidate Aec2 alleles needed for SS xerostomia. PMID:24685748

  16. PULSE SYNTHESIZING GENERATOR

    DOEpatents

    Kerns, Q.A.

    1963-08-01

    >An electronlc circuit for synthesizing electrical current pulses having very fast rise times includes several sinewave generators tuned to progressively higher harmonic frequencies with signal amplitudes and phases selectable according to the Fourier series of the waveform that is to be synthesized. Phase control is provided by periodically triggering the generators at precisely controlled times. The outputs of the generators are combined in a coaxial transmission line. Any frequency-dependent delays that occur in the transmission line can be readily compensated for so that the desired signal wave shape is obtained at the output of the line. (AEC)

  17. Project 57 Air Monitoring Report: January 1 through December 31, 2015

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mizell, Steve A; Nikolich, George; Shadel, Craig

    2017-01-01

    On April 24, 1957, the Atomic Energy Commission (AEC, now the Department of Energy [DOE]) conducted the Project 57 safety experiment in western Emigrant Valley north east of the Nevada National Security Site (NNSS, formerly the Nevada Test Site) on lands withdrawn by the Department of Defense (DOD) for the Nevada Test and Training Range (NTTR). The test was undertaken to develop (1) a means of estimating plutonium distribution resulting from a non-nuclear detonation; (2) biomedical evaluation techniques for use in plutonium-laden environments; (3) methods of surface decontamination; and (4) instruments and field procedures for prompt estimation of alpha contaminationmore » (Shreve, 1958). Although the test did not result in the fission of nuclear materials, it did disseminate plutonium across the land surface. Following the experiment, the AEC fenced the contaminated area and returned control of the surrounding land to the DOD. Various radiological surveys were performed in the area and in 2007, the DOE expanded the demarked Contamination Area by posting signs 200 to 400 feet (60 to 120 meters) outside of the original fence.« less

  18. Project 57 Air Monitoring Report: January 1 through December 31, 2016

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mizell, Steve A.; Nikolich, George; Shadel, Craig

    On April 24, 1957, the Atomic Energy Commission (AEC, now the Department of Energy [DOE]) conducted the Project 57 safety experiment in western Emigrant Valley northeast of the Nevada National Security Site (NNSS, formerly the Nevada Test Site) on lands withdrawn by the Department of Defense (DOD) for the Nevada Test and Training Range (NTTR). The test was undertaken to develop (1) a means of estimating plutonium distribution resulting from a non-nuclear detonation; (2) biomedical evaluation techniques for use in plutonium-laden environments; (3) methods of surface decontamination; and (4) instruments and field procedures for prompt estimation of alpha contamination (Shreve,more » 1958). Although the test did not result in the fission of nuclear materials, it did disseminate plutonium across the land surface. Following the experiment, the AEC fenced the contaminated area and returned control of the surrounding land to the DOD. Various radiological surveys were performed in the area and in 2007, the DOE expanded the demarked Contamination Area (CA) by posting signs 200 to 400 ft (60 to 120 m) outside of the original fence.« less

  19. REACTOR CONTROL

    DOEpatents

    Fortescue, P.; Nicoll, D.

    1962-04-24

    A control system employed with a high pressure gas cooled reactor in which a control rod is positioned for upward and downward movement into the neutron field from a position beneath the reactor is described. The control rod is positioned by a coupled piston cylinder releasably coupled to a power drive means and the pressurized coolant is directed against the lower side of the piston. The coolant pressure is offset by a higher fiuid pressure applied to the upper surface of the piston and means are provided for releasing the higher pressure on the upper side of the piston so that the pressure of the coolant drives the piston upwardly, forcing the coupled control rod into the ncutron field of the reactor. (AEC)

  20. Adaptive Sampling approach to environmental site characterization at Joliet Army Ammunition Plant: Phase 2 demonstration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bujewski, G.E.; Johnson, R.L.

    1996-04-01

    Adaptive sampling programs provide real opportunities to save considerable time and money when characterizing hazardous waste sites. This Strategic Environmental Research and Development Program (SERDP) project demonstrated two decision-support technologies, SitePlanner{trademark} and Plume{trademark}, that can facilitate the design and deployment of an adaptive sampling program. A demonstration took place at Joliet Army Ammunition Plant (JAAP), and was unique in that it was tightly coupled with ongoing Army characterization work at the facility, with close scrutiny by both state and federal regulators. The demonstration was conducted in partnership with the Army Environmental Center`s (AEC) Installation Restoration Program and AEC`s Technology Developmentmore » Program. AEC supported researchers from Tufts University who demonstrated innovative field analytical techniques for the analysis of TNT and DNT. SitePlanner{trademark} is an object-oriented database specifically designed for site characterization that provides an effective way to compile, integrate, manage and display site characterization data as it is being generated. Plume{trademark} uses a combination of Bayesian analysis and geostatistics to provide technical staff with the ability to quantitatively merge soft and hard information for an estimate of the extent of contamination. Plume{trademark} provides an estimate of contamination extent, measures the uncertainty associated with the estimate, determines the value of additional sampling, and locates additional samples so that their value is maximized.« less

  1. REACTOR HAVING NaK-UO$sub 2$ SLURRY HELICALLY POSITIONED IN A GRAPHITE MODERATOR

    DOEpatents

    Rodin, M.B.; Carter, J.C.

    1962-05-15

    A reactor utilizing 20% enriched uranium consists of a central graphite island in cylindrical form, with a spiral coil of tubing fitting against the central island. An external graphite moderator is placed around the central island and coil. A slurry of uranium dioxide dispersed in alkali metal passes through the coil to transfer heat externally to the reactor. There are also conventional controls for regulating the nuclear reaction. (AEC)

  2. An iterative truncation method for unbounded electromagnetic problems using varying order finite elements

    NASA Astrophysics Data System (ADS)

    Paul, Prakash

    2009-12-01

    The finite element method (FEM) is used to solve three-dimensional electromagnetic scattering and radiation problems. Finite element (FE) solutions of this kind contain two main types of error: discretization error and boundary error. Discretization error depends on the number of free parameters used to model the problem, and on how effectively these parameters are distributed throughout the problem space. To reduce the discretization error, the polynomial order of the finite elements is increased, either uniformly over the problem domain or selectively in those areas with the poorest solution quality. Boundary error arises from the condition applied to the boundary that is used to truncate the computational domain. To reduce the boundary error, an iterative absorbing boundary condition (IABC) is implemented. The IABC starts with an inexpensive boundary condition and gradually improves the quality of the boundary condition as the iteration continues. An automatic error control (AEC) is implemented to balance the two types of error. With the AEC, the boundary condition is improved when the discretization error has fallen to a low enough level to make this worth doing. The AEC has these characteristics: (i) it uses a very inexpensive truncation method initially; (ii) it allows the truncation boundary to be very close to the scatterer/radiator; (iii) it puts more computational effort on the parts of the problem domain where it is most needed; and (iv) it can provide as accurate a solution as needed depending on the computational price one is willing to pay. To further reduce the computational cost, disjoint scatterers and radiators that are relatively far from each other are bounded separately and solved using a multi-region method (MRM), which leads to savings in computational cost. A simple analytical way to decide whether the MRM or the single region method will be computationally cheaper is also described. To validate the accuracy and savings in computation time, different shaped metallic and dielectric obstacles (spheres, ogives, cube, flat plate, multi-layer slab etc.) are used for the scattering problems. For the radiation problems, waveguide excited antennas (horn antenna, waveguide with flange, microstrip patch antenna) are used. Using the AEC the peak reduction in computation time during the iteration is typically a factor of 2, compared to the IABC using the same element orders throughout. In some cases, it can be as high as a factor of 4.

  3. Point Organ Radiation Dose in Abdominal CT: Effect of Patient Off-Centering in an Experimental Human Cadaver Study.

    PubMed

    Ali Khawaja, Ranish Deedar; Singh, Sarabjeet; Padole, Atul; Otrakji, Alexi; Lira, Diego; Zhang, Da; Liu, Bob; Primak, Andrew; Xu, George; Kalra, Mannudeep K

    2017-08-01

    To determine the effect of patient off-centering on point organ radiation dose measurements in a human cadaver scanned with routine abdominal CT protocol. A human cadaver (88 years, body-mass-index 20 kg/m2) was scanned with routine abdominal CT protocol on 128-slice dual source MDCT (Definition Flash, Siemens). A total of 18 scans were performed using two scan protocols (a) 120 kV-200 mAs fixed-mA (CTDIvol 14 mGy) (b) 120 kV-125 ref mAs (7 mGy) with automatic exposure control (AEC, CareDose 4D) at three different positions (a) gantry isocenter, (b) upward off-centering and (c) downward off-centering. Scanning was repeated three times at each position. Six thimble (in liver, stomach, kidney, pancreas, colon and urinary bladder) and four MOSFET dosimeters (on cornea, thyroid, testicle and breast) were placed for calculation of measured point organ doses. Organ dose estimations were retrieved from dose-tracking software (eXposure, Radimetrics). Statistical analysis was performed using analysis of variance. There was a significant difference between the trends of point organ doses with AEC and fixed-mA at all three positions (p < 0.01). Variation in point doses between fixed-mA and AEC protocols were statistically significant across all organs at all Table positions (p < 0.001). There was up to 5-6% decrease in point doses with upward off-centering and in downward off-centering. There were statistical significant differences in point doses from dosimeters and dose-tracking software (mean difference for internal organs, 5-36% for fixed-mA & 7-48% for AEC protocols; p < 0.001; mean difference for surface organs, >92% for both protocols; p < 0.0001). For both protocols, the highest mean difference in point doses was found for stomach and lowest for colon. Measured absorbed point doses in abdominal CT vary with patient-centering in the gantry isocenter. Due to lack of consideration of patient positioning in the dose estimation on automatic software-over estimation of the doses up to 92% was reported. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. HIGH PRESSURE GAS REGULATOR

    DOEpatents

    Ramage, R.W.

    1962-05-01

    A gas regulator operating on the piston and feedback principle is described. The device is particularly suitable for the delicate regulation of high pressure, i.e., 10,000 psi and above, gas sources, as well as being perfectly adaptable for use on gas supplies as low as 50 psi. The piston is adjustably connected to a needle valve and the movement of the piston regulates the flow of gas from the needle valve. The gas output is obtained from the needle valve. Output pressure is sampled by a piston feedback means which, in turn, regulates the movement of the main piston. When the output is other than the desired value, the feedback system initiates movement of the main piston to allow the output pressure to be corrected or to remain constant. (AEC)

  5. A new formula for a mild body cleanser: sodium laureth sulphate supplemented with sodium laureth carboxylate and lauryl glucoside.

    PubMed

    Takagi, Y; Shimizu, M; Morokuma, Y; Miyaki, M; Kiba, A; Matsuo, K; Isoda, K; Mizutani, H

    2014-08-01

    Sodium laureth sulphate (SLES) is an anionic detergent, which has been used globally for personal care products because of its mildness and good foaming ability. However, SLES is somewhat invasive and stimulatory to the skin, and many consumers with sensitive skin desire milder detergents for daily use skin cleansers. We enhanced the mildness of SLES by formulating it with sodium laureth carboxylate (AEC) and lauryl glucoside (LG). In skin soak tests, 5% detergent solutions were applied to the forearms of 10 Japanese healthy volunteers for 30 min followed by washing with tap water once a day for 4 days. Twenty-four hours after the last treatment, cutaneous capacitance measurements and visual analyses were performed. In a controlled usage study, 16 Japanese healthy volunteers used the test body cleanser for 4 weeks. Assessment of efficacy and mildness was conducted prior to the start of the study and at the end of week 4 by cutaneous conductance, dermoscopic evaluation of the stratum corneum and visual assessment by a dermatologist. In soak tests, cutaneous capacitance was significantly decreased on the soap-treated region and on the SLES-treated region. No significant decrease was identified on the SLES/AEC/LG-treated region with less induction of erythema or dryness. In the controlled usage study, no significant changes in cutaneous conductance or texture or damage of corneocytes on the forearm and lower thigh were found. However, visual assessment revealed a significant decrease in scaling and erythema on the lower thigh after 4 weeks of usage with an improvement of the discomfort of the consumer. The favourability rating of this formulated detergent in several questionnaire items was very good. The newly formulated skin cleanser with the combination of anionic surfactants SLES and AEC and the non-ionic surfactant LG provides a mild surfactant with a satisfactory cleansing activity for body washing. © 2014 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  6. SU-F-I-31: Reproducibility of An Automatic Exposure Control Technique in the Low-Dose CT Scan of Cardiac PET/CT Exams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, M; Rosica, D; Agarwal, V

    Purpose: Two separate low-dose CT scans are usually performed for attenuation correction of rest and stress N-13 ammonia PET/CT myocardial perfusion imaging (PET/CT). We utilize an automatic exposure control (AEC) technique to reduce CT radiation dose while maintaining perfusion image quality. Our goal is to assess the reproducibility of displayed CT dose index (CTDI) on same-day repeat CT scans (CT1 and CT2). Methods: Retrospectively, we reviewed CT images of PET/CT studies performed on the same day. Low-dose CT utilized AEC technique based on tube current modulation called Smart-mA. The scan parameters were 64 × 0.625mm collimation, 5mm slice thickness, 0.984more » pitch, 1-sec rotation time, 120 kVp, and noise index 50 with a range of 10–200 mA. The scan length matched with PET field of view (FOV) with the heart near the middle of axial FOV. We identified the reference slice number (RS) for an anatomical landmark (carina) and used it to estimate axial shift between two CTs. For patient size, we measured an effective diameter on the reference slice. The effect of patient positioning to CTDI was evaluated using the table height. We calculated the absolute percent difference of the CTDI (%diff) for estimation of the reproducibility. Results: The study included 168 adults with an average body-mass index of 31.72 ± 9.10 (kg/m{sup 2}) and effective diameter was 32.72 ± 4.60 cm. The average CTDI was 1.95 ± 1.40 mGy for CT1 and 1.97 ± 1.42mGy for CT2. The mean %diff was 7.8 ± 6.8%. Linear regression analysis showed a significant correlation between the table height and %diff CTDI. (r=0.82, p<0.001) Conclusion: We have shown for the first time in human subjects, using two same-day CT images, that the AEC technique in low-dose CT is reproducible within 10% and significantly depends on the patient centering.« less

  7. Endogenous Murine BST-2/Tetherin Is Not a Major Restriction Factor of Influenza A Virus Infection.

    PubMed

    Londrigan, Sarah L; Tate, Michelle D; Job, Emma R; Moffat, Jessica M; Wakim, Linda M; Gonelli, Christopher A; Purcell, Damien F J; Brooks, Andrew G; Villadangos, Jose A; Reading, Patrick C; Mintern, Justine D

    2015-01-01

    BST-2 (tetherin, CD317, HM1.24) restricts virus growth by tethering enveloped viruses to the cell surface. The role of BST-2 during influenza A virus infection (IAV) is controversial. Here, we assessed the capacity of endogenous BST-2 to restrict IAV in primary murine cells. IAV infection increased BST-2 surface expression by primary macrophages, but not alveolar epithelial cells (AEC). BST-2-deficient AEC and macrophages displayed no difference in susceptibility to IAV infection relative to wild type cells. Furthermore, BST-2 played little role in infectious IAV release from either AEC or macrophages. To examine BST-2 during IAV infection in vivo, we infected BST-2-deficient mice. No difference in weight loss or in viral loads in the lungs and/or nasal tissues were detected between BST-2-deficient and wild type animals. This study rules out a major role for endogenous BST-2 in modulating IAV in the mouse model of infection.

  8. Solid oxide fuel cell with multi-unit construction and prismatic design

    DOEpatents

    McPheeters, C.C.; Dees, D.W.; Myles, K.M.

    1999-03-16

    A single cell unit of a solid oxide fuel cell is described that is individually fabricated and sintered prior to being connected to adjacent cells to form a solid oxide fuel cell. The single cell unit is comprised of a shaped anode sheet positioned between a flat anode sheet and an anode-electrolyte-cathode (A/E/C) sheet, and a shaped cathode sheet positioned between the A/E/C sheet and a cathode-interconnect-anode (C/I/A) sheet. An alternate embodiment comprises a shaped cathode sheet positioned between an A/E/C sheet and a C/I/A sheet. The shaped sheets form channels for conducting reactant gases. Each single cell unit is individually sintered to form a finished sub-assembly. The finished sub-assemblies are connected in electrical series by interposing connective material between the end surfaces of adjacent cells, whereby individual cells may be inspected for defects and interchanged with non-defective single cell units. 7 figs.

  9. Endogenous Murine BST-2/Tetherin Is Not a Major Restriction Factor of Influenza A Virus Infection

    PubMed Central

    Job, Emma R.; Moffat, Jessica M.; Wakim, Linda M.; Gonelli, Christopher A.; Purcell, Damien F. J.; Brooks, Andrew G.; Villadangos, Jose A.; Reading, Patrick C.; Mintern, Justine D.

    2015-01-01

    BST-2 (tetherin, CD317, HM1.24) restricts virus growth by tethering enveloped viruses to the cell surface. The role of BST-2 during influenza A virus infection (IAV) is controversial. Here, we assessed the capacity of endogenous BST-2 to restrict IAV in primary murine cells. IAV infection increased BST-2 surface expression by primary macrophages, but not alveolar epithelial cells (AEC). BST-2-deficient AEC and macrophages displayed no difference in susceptibility to IAV infection relative to wild type cells. Furthermore, BST-2 played little role in infectious IAV release from either AEC or macrophages. To examine BST-2 during IAV infection in vivo, we infected BST-2-deficient mice. No difference in weight loss or in viral loads in the lungs and/or nasal tissues were detected between BST-2-deficient and wild type animals. This study rules out a major role for endogenous BST-2 in modulating IAV in the mouse model of infection. PMID:26566124

  10. PRESSURIZED WATER REACTOR CORE WITH PLUTONIUM BURNUP

    DOEpatents

    Puechl, K.H.

    1963-09-24

    A pressurized water reactor is described having a core containing Pu/sup 240/ in which the effective microscopic neutronabsorption cross section of Pu/sup 240/ in unconverted condition decreases as the time of operation of the reactor increases, in order to compensate for loss of reactivity resulting from fission product buildup during reactor operation. This means serves to improve the efficiency of the reactor operation by reducing power losses resulting from control rods and burnable poisons. (AEC)

  11. PROCESS FOR CONTROLLING ANIMAL GROWTH RATE

    DOEpatents

    Visek, W.J.

    1962-04-10

    A method of injecting growing animals with the enzyme urease subcutaneously in increasing dosages is described; this generates within the blood anti-urease which enters the intestinal tract and inhibits the enzymatic decomposition of urea by urease in that location. Ammonia, one of the decomposition products, is thereby kept from diffusing through the intestinal walls into the blood, and this greatly reduces the energy requirements of the liver for removing the ammonia, thereby increasing the feeding efficiency of the animals. (AEC)

  12. Shot PRISCILLA: A Test of the PLUMBBOB Series, 24 June 1957.

    DTIC Science & Technology

    1981-02-27

    Block 20. If different from Report) I6. SUPPLEMENTARY NOTES This Work sponsored by the Defense Nuclear Agency under RDT&E RMSS Code B350079464...rile Defense Nuclear Agency Action Officer, Major H. L. Reese, under whom this work was done, wishes to acknowledge the research and editing...Operation PLUMBBOB. All activities of the NTO were under the overall control of an AEC-appointed Test Manager, assisted by the Test Director. The NTO

  13. Sexual dimorphic function of IL-17 in salivary gland dysfunction of the C57BL/6.NOD-Aec1Aec2 model of Sjögren's syndrome.

    PubMed

    Voigt, Alexandria; Esfandiary, Lida; Wanchoo, Arun; Glenton, Patricia; Donate, Amy; Craft, William F; Craft, Serena L M; Nguyen, Cuong Q

    2016-12-13

    Interleukin (IL)-17 is one of the critical inflammatory cytokines that plays a direct role in development of Sjögren's syndrome (SjS), a systemic autoimmune disease characterized by a progressive chronic attack against the exocrine glands. The expression levels of IL-17 are correlated with a number of essential clinical parameters such as focus score and disease duration in human patients. Significantly immunological differences of Th17 cells were detected at the onset of clinical disease in female SjS mice compared to males. To further define the role of IL-17 in SjS and elucidate its involvement in the sexual dimorphism, we examined the systemic effect of IL-17 by genetically ablating Il-17 in the C57BL/6.NOD-Aec1Aec2, spontaneous SjS murine model. The results indicate that IL-17 is a potent inflammatory molecule in the induction of chemoattractants, cytokines, and glandular apoptosis in males and females. Elimination of IL-17 reduced sialadenitis more drastically in females than males. IL-17 is highly involved in modulating Th2 cytokines and altering autoantibody profiles which has a greater impact on changing plasma cells and germinal center B cell populations in females than males. The result supports a much more important role for IL-17 and demonstrates the sexual dimorphic function of IL-17 in SjS.

  14. Sexual dimorphic function of IL-17 in salivary gland dysfunction of the C57BL/6.NOD-Aec1Aec2 model of Sjögren’s syndrome

    PubMed Central

    Voigt, Alexandria; Esfandiary, Lida; Wanchoo, Arun; Glenton, Patricia; Donate, Amy; Craft, William F.; Craft, Serena L. M.; Nguyen, Cuong Q.

    2016-01-01

    Interleukin (IL)-17 is one of the critical inflammatory cytokines that plays a direct role in development of Sjögren’s syndrome (SjS), a systemic autoimmune disease characterized by a progressive chronic attack against the exocrine glands. The expression levels of IL-17 are correlated with a number of essential clinical parameters such as focus score and disease duration in human patients. Significantly immunological differences of Th17 cells were detected at the onset of clinical disease in female SjS mice compared to males. To further define the role of IL-17 in SjS and elucidate its involvement in the sexual dimorphism, we examined the systemic effect of IL-17 by genetically ablating Il-17 in the C57BL/6.NOD-Aec1Aec2, spontaneous SjS murine model. The results indicate that IL-17 is a potent inflammatory molecule in the induction of chemoattractants, cytokines, and glandular apoptosis in males and females. Elimination of IL-17 reduced sialadenitis more drastically in females than males. IL-17 is highly involved in modulating Th2 cytokines and altering autoantibody profiles which has a greater impact on changing plasma cells and germinal center B cell populations in females than males. The result supports a much more important role for IL-17 and demonstrates the sexual dimorphic function of IL-17 in SjS. PMID:27958291

  15. The NRF2 Activation and Antioxidative Response Are Not Impaired Overall during Hyperoxia-Induced Lung Epithelial Cell Death

    PubMed Central

    Potteti, Haranatha R.; Reddy, Narsa M.; Hei, Tom K.; Kalvakolanu, Dhananjaya V.; Reddy, Sekhar P.

    2013-01-01

    Lung epithelial and endothelial cell death caused by pro-oxidant insults is a cardinal feature of acute lung injury/acute respiratory distress syndrome (ALI/ARDS) patients. The NF-E2-related factor 2 (NRF2) activation in response to oxidant exposure is crucial to the induction of several antioxidative and cytoprotective enzymes that mitigate cellular stress. Since prolonged exposure to hyperoxia causes cell death, we hypothesized that chronic hyperoxia impairs NRF2 activation, resulting in cell death. To test this hypothesis, we exposed nonmalignant small airway epithelial cells (AECs) to acute (1–12 h) and chronic (36–48 h) hyperoxia and evaluated cell death, NRF2 nuclear accumulation and target gene expression, and NRF2 recruitment to the endogenous HMOX1 and NQO1 promoters. As expected, hyperoxia gradually induced death in AECs, noticeably and significantly by 36 h; ~60% of cells were dead by 48 h. However, we unexpectedly found increased expression levels of NRF2-regulated antioxidative genes and nuclear NRF2 in AECs exposed to chronic hyperoxia as compared to acute hyperoxia. Chromatin Immunoprecipitation (ChIP) assays revealed an increased recruitment of NRF2 to the endogenous HMOX1 and NQO1 promoters in AECs exposed to acute or chronic hyperoxia. Thus, our findings demonstrate that NRF2 activation and antioxidant gene expression are functional during hyperoxia-induced lung epithelial cell death and that chronic hyperoxia does not impair NRF2 signaling overall. PMID:23738042

  16. Correction method for influence of tissue scattering for sidestream dark-field oximetry using multicolor LEDs

    NASA Astrophysics Data System (ADS)

    Kurata, Tomohiro; Oda, Shigeto; Kawahira, Hiroshi; Haneishi, Hideaki

    2016-12-01

    We have previously proposed an estimation method of intravascular oxygen saturation (SO_2) from the images obtained by sidestream dark-field (SDF) imaging (we call it SDF oximetry) and we investigated its fundamental characteristics by Monte Carlo simulation. In this paper, we propose a correction method for scattering by the tissue and performed experiments with turbid phantoms as well as Monte Carlo simulation experiments to investigate the influence of the tissue scattering in the SDF imaging. In the estimation method, we used modified extinction coefficients of hemoglobin called average extinction coefficients (AECs) to correct the influence from the bandwidth of the illumination sources, the imaging camera characteristics, and the tissue scattering. We estimate the scattering coefficient of the tissue from the maximum slope of pixel value profile along a line perpendicular to the blood vessel running direction in an SDF image and correct AECs using the scattering coefficient. To evaluate the proposed method, we developed a trial SDF probe to obtain three-band images by switching multicolor light-emitting diodes and obtained the image of turbid phantoms comprised of agar powder, fat emulsion, and bovine blood-filled glass tubes. As a result, we found that the increase of scattering by the phantom body brought about the decrease of the AECs. The experimental results showed that the use of suitable values for AECs led to more accurate SO_2 estimation. We also confirmed the validity of the proposed correction method to improve the accuracy of the SO_2 estimation.

  17. Hypoxia increases transepithelial electrical conductance and reduces occludin at the plasma membrane in alveolar epithelial cells via PKC-ζ and PP2A pathway

    PubMed Central

    Caraballo, Juan Carlos; Yshii, Cecilia; Butti, Maria L.; Westphal, Whitney; Borcherding, Jennifer A.; Allamargot, Chantal

    2011-01-01

    During pulmonary edema, the alveolar space is exposed to a hypoxic environment. The integrity of the alveolar epithelial barrier is required for the reabsorption of alveolar fluid. Tight junctions (TJ) maintain the integrity of this barrier. We set out to determine whether hypoxia creates a dysfunctional alveolar epithelial barrier, evidenced by an increase in transepithelial electrical conductance (Gt), due to a decrease in the abundance of TJ proteins at the plasma membrane. Alveolar epithelial cells (AEC) exposed to mild hypoxia (Po2 = 50 mmHg) for 30 and 60 min decreased occludin abundance at the plasma membrane and significantly increased Gt. Other cell adhesion molecules such as E-cadherin and claudins were not affected by hypoxia. AEC exposed to hypoxia increased superoxide, but not hydrogen peroxide (H2O2). Overexpression of superoxide dismutase 1 (SOD1) but not SOD2 prevented the hypoxia-induced Gt increase and occludin reduction in AEC. Also, overexpression of catalase had a similar effect as SOD1, despite not detecting any increase in H2O2 during hypoxia. Blocking PKC-ζ and protein phosphatase 2A (PP2A) prevented the hypoxia-induced occludin reduction at the plasma membrane and increase in Gt. In summary, we show that superoxide, PKC-ζ, and PP2A are involved in the hypoxia-induced increase in Gt and occludin reduction at the plasma membrane in AEC. PMID:21257729

  18. Amchitka Island, Alaska, Biological Monitoring Report 2011 Sampling Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    The Long-Term Surveillance and Maintenance (LTS&M) Plan for the U.S. Department of Energy (DOE) Office of Legacy Management (LM) Amchitka Island sites describes how LM plans to conduct its mission to protect human health and the environment at the three nuclear test sites located on Amchitka Island, Alaska. Amchitka Island, near the western end of the Aleutian Islands, is approximately 1,340 miles west-southwest of Anchorage, Alaska. Amchitka is part of the Aleutian Island Unit of the Alaska Maritime National Wildlife Refuge, which is administered by the U.S. Fish and Wildlife Service (USFWS). Since World War II, Amchitka has been usedmore » by multiple U.S. government agencies for various military and research activities. From 1943 to 1950, it was used as a forward air base for the U.S. Armed Forces. During the middle 1960s and early 1970s, the U.S. Department of Defense (DOD) and the U.S. Atomic Energy Commission (AEC) used a portion of the island as a site for underground nuclear tests. During the late 1980s and early 1990s, the U.S. Navy constructed and operated a radar station on the island. Three underground nuclear tests were conducted on Amchitka Island. DOD, in conjunction with AEC, conducted the first nuclear test (named Long Shot) in 1965 to provide data that would improve the United States' capability of detecting underground nuclear explosions. The second nuclear test (Milrow) was a weapons-related test conducted by AEC in 1969 as a means to study the feasibility of detonating a much larger device. Cannikin, the third nuclear test on Amchitka, was a weapons-related test detonated on November 6, 1971. With the exception of small concentrations of tritium detected in surface water shortly after the Long Shot test, radioactive fission products from the tests remain in the subsurface at each test location As a continuation of the environmental monitoring that has taken place on Amchitka Island since before 1965, LM in the summer of 2011 collected biological and seawater samples from the marine and terrestrial environment of Amchitka Island adjacent to the three detonation sites and at a background or reference site, Adak Island, 180 miles to the east. Consistent with the goals of the Amchitka LTS&M Plan, four data quality objectives (DQOs) were developed for the 2011 sampling event.« less

  19. Complicated diverticular disease: Position statement on outpatient management, Hartmann's procedure, laparoscopic peritoneal lavage and laparoscopic approach. Consensus document of the Spanish Association of Coloproctology and the Coloproctology Section of the Spanish Association of Surgeons.

    PubMed

    Rosado-Cobián, Rafael; Blasco-Segura, Teresa; Ferrer-Márquez, Manuel; Marín-Ortega, Héctor; Pérez-Domínguez, Lucinda; Biondo, Sebastiano; Roig-Vila, José Vicente

    The Spanish Association of Coloproctology (AECP) and the Coloproctology Section of the Spanish Association of Surgeons (AEC), propose this consensus document about complicated diverticular disease that could be used for decision-making. Outpatient management, Hartmann's procedure, laparoscopic peritoneal lavage, and the role of a laparoscopic approach in colonic resection are exposed. Copyright © 2017 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Conservation Process Model (cpm): a Twofold Scientific Research Scope in the Information Modelling for Cultural Heritage

    NASA Astrophysics Data System (ADS)

    Fiorani, D.; Acierno, M.

    2017-05-01

    The aim of the present research is to develop an instrument able to adequately support the conservation process by means of a twofold approach, based on both BIM environment and ontology formalisation. Although BIM has been successfully experimented within AEC (Architecture Engineering Construction) field, it has showed many drawbacks for architectural heritage. To cope with unicity and more generally complexity of ancient buildings, applications so far developed have shown to poorly adapt BIM to conservation design with unsatisfactory results (Dore, Murphy 2013; Carrara 2014). In order to combine achievements reached within AEC through BIM environment (design control and management) with an appropriate, semantically enriched and flexible The presented model has at its core a knowledge base developed through information ontologies and oriented around the formalization and computability of all the knowledge necessary for the full comprehension of the object of architectural heritage an its conservation. Such a knowledge representation is worked out upon conceptual categories defined above all within architectural criticism and conservation scope. The present paper aims at further extending the scope of conceptual modelling within cultural heritage conservation already formalized by the model. A special focus is directed on decay analysis and surfaces conservation project.

  1. Positive Enteric Contrast Material for Abdominal and Pelvic CT with Automatic Exposure Control: What Is the Effect On Patient Radiation Exposure?

    PubMed Central

    Wang, Zhen J.; Chen, Katherine S.; Gould, Robert; Coakley, Fergus V.; Fu, Yanjun; Yeh, Benjamin M.

    2014-01-01

    Objective To assess the effect of positive enteric contrast administration on automatic exposure control (AEC) CT radiation exposure in 1) a CT phantom, and 2) a retrospective review of patients. Materials and Methods We scanned a CT phantom containing simulated bowel that was sequentially filled with water and positive enteric contrast, and recorded the mean volume CT dose index (CTDIvol). We also identified 17 patients who had undergone 2 technically comparable CT scans of the abdomen and pelvis, one with positive enteric contrast and the other with oral water. Paired student t-tests were used to compare the mean CTDIvol between scans performed with and without positive enteric contrast. Both the phantom and patient CT scans were performed using AEC with a fixed noise index. Results The mean CTDIvol for the phantom with simulated bowel containing water and positive enteric contrast were 8.2 ± 0.2 mGy, and 8.7 ± 0.1 mGy (6.1% higher than water, p=0.02), respectively. The mean CTDIvol for patients scanned with oral water and with positive enteric contrast were 11.8mGy and 13.1mGy, respectively (p=0.003). This corresponded to a mean CTDIvol which was 11.0% higher (range: 0.0–20.7% higher) in scans with positive enteric contrast than those with oral water in patients. Conclusions When automatic exposure control is utilized for abdominopelvic CT, the radiation exposure, as measured by CTDIvol, is higher for scans performed with positive enteric contrast than those with oral water. PMID:21493028

  2. CORE SATURATION BLOCKING OSCILLATOR

    DOEpatents

    Spinrad, R.J.

    1961-10-17

    A blocking oscillator which relies on core saturation regulation to control the output pulse width is described. In this arrangement an external magnetic loop is provided in which a saturable portion forms the core of a feedback transformer used with the thermionic or semi-conductor active element. A first stationary magnetic loop establishes a level of flux through the saturation portion of the loop. A second adjustable magnet moves the flux level to select a saturation point giving the desired output pulse width. (AEC)

  3. ALLOY COMPOSITION FOR NEUTRONIC REACTOR CONTROL RODS

    DOEpatents

    Lustman, B.; Losco, E.F.; Snyder, H.J.; Eggleston, R.R.

    1963-01-22

    This invention relates to alloy compositons suitable as cortrol rod material consisting of, by weight, from 85% to 85% Ag, from 2% to 20% In, from up to 10% of Cd, from up to 5% Sn, and from up to 1.5% Al, the amount of each element employed being determined by the equation X + 2Y + 3Z + 3W + 4V = 1.4 and less, where X, Y, Z, W, and V represent the atom fractions of the elements Ag, Cd, In, Al and Sn. (AEC)

  4. DENSITY CONTROL IN A REACTOR

    DOEpatents

    Marshall, J. Jr.

    1961-10-24

    A reactor is described in which natural-uranium bodies are located in parallel channels which extend through the graphite mass in a regular lattice. The graphite mass has additional channels that are out of the lattice and contain no uranium. These additional channels decrease in number per unit volume of graphite from the center of the reactor to the exterior and have the effect of reducing the density of the graphite more at the center than at the exterior, thereby spreading neutron activity throughout the reactor. (AEC)

  5. Structural Modeling and Response of Command, Control and Communication Shelter Systems for Event DICE THROW.

    DTIC Science & Technology

    1980-03-01

    Construction ... ........... ... 71 7 FkAEC"IWAG FitAZbL~ai-am naJ" LIST OF ILLUSTRATIONS (CONT’D) Figure Page 2.26 Grid Point System for AN/TRC-145...systems consists of a basic shelter structure whose side walls are of sandwich construction with internal stiffeners. Channel extrusions along each...free edge of the shelter provide additional strength and stiffening. The shelters contain electronic equipment racks of open framework construction using

  6. MULTIPLIER CIRCUIT

    DOEpatents

    Chase, R.L.

    1963-05-01

    An electronic fast multiplier circuit utilizing a transistor controlled voltage divider network is presented. The multiplier includes a stepped potentiometer in which solid state or transistor switches are substituted for mechanical wipers in order to obtain electronic switching that is extremely fast as compared to the usual servo-driven mechanical wipers. While this multiplier circuit operates as an approximation and in steps to obtain a voltage that is the product of two input voltages, any desired degree of accuracy can be obtained with the proper number of increments and adjustment of parameters. (AEC)

  7. APPARATUS FOR CONTROL OF HIGH-ENERGY ACCELERATORS

    DOEpatents

    Heard, H.G.

    1961-10-24

    A particle beam positioning control for a synchrotron or the like is described. The control includes means for selectively impressing a sinusoidal perturbation upon the rising voltage utilized to sweep the frequency of the f-m oscillator which is conventionally coupled to the accelerating electrode of a synchrotron. The perturbation produces a variation in the normal rate of change of frequency of the accelerating voltage applied to the accelerating electrode, resulting in an expansion or contraction of the particle beam orbit diameter during the perturbation. The beam may thus be controlled such that a portion strikes a target positioned close to the expanded or contracted orbit diameter and returns to the original orbit for further acceleration to the final energy. (AEC)

  8. The impact of serum incubation time on IgM/IgG binding to porcine aortic endothelial cells.

    PubMed

    Zhang, Zhongqiang; Gao, Bingsi; Zhao, Chengjiang; Long, Cassandra; Qi, Haizhi; Ezzelarab, Mohamed; Cooper, David Kc; Hara, Hidetaka

    2017-07-01

    The results of the assay for measuring anti-non-Gal antibodies (which affect pig xenograft survival) in recipients are important. Serum incubation time and concentration may be important factors in the extent of antibody binding to the graft. The aim of this in vitro study was to determine the optimal incubation time and serum concentration for measuring anti-non-Gal antibody binding to porcine aortic endothelial cells (pAECs). Pooled human, naive, and sensitized baboon sera were incubated with wild-type, α1,3-galactosyltransferase gene-knockout (GTKO), and GTKO/human CD55 pAECs. IgM/IgG binding to pAECs after varying serum incubation times (0.5, 1, 2, and 3 hour) and concentrations (5, 10, 20, and 40 μL) was determined by flow cytometry. An increase in incubation time from 30 minutes to 2 hour was associated with increases in anti-non-Gal IgM/IgG binding to GTKO and GTKO/hCD55 pAECs of pooled human, naive and sensitized baboon sera (P<.05). Pooled human serum showed a significant increase in anti-non-Gal IgM (1.5 times) and a minimal increase in anti-non-Gal IgG antibody binding. IgM/IgG binding of sensitized baboon serum to GTKO pAECs after 2-hour incubation was 1.5 times and 2 times greater than after 30-minutes incubation, respectively, whereas naïve baboon sera showed minimal (non-significant) increase in anti-non-Gal IgM/IgG antibody binding. With 2-hour incubation, increasing the serum concentration from 5 μL to 20 μL significantly increased antibody binding to non-Gal antigens in pooled human and sensitized baboon serum. With naïve baboon serum, only IgG was significantly increased. Increasing the serum incubation time contributed to improve the sensitivity of detecting anti-non-Gal antibodies, without affecting cell viability in vitro. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. An overview of the draft for the amendment of 'nuclear materials and radioactive waste management act'

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huan Lin; Tai-Wei Lan; Min-Tsang Chang

    2013-07-01

    The 'Nuclear Materials and Radioactive Waste Management Act' (NMRWMA) in Taiwan has been in use since 2002. To promote further administrative efficiency and improve regulatory capacity, an amendment of the act has been initiated by the Atomic Energy Council (AEC). It is now being reviewed by outside experts and related communities so as to include the best understanding of risk management factors. For the future decommissioning challenges of nuclear facilities, the act is also being amended to comply with the regulatory requirements of the decommissioning mandates. Currently the Taiwan government is conducting government reorganization, and AEC will be reformed butmore » will remain as an independent regulatory body. AEC will then be capable of improving the regulatory capacity for facilitating licensing and inspection, ensuring operational safety, environmental protection and public involvement, and giving a more flexible administrative discretion, such as expending the margin of penalty. The amendment is also required to provide a formal legal basis for the Nuclear Backend Fund, and to mandate the waste producers to take responsibility for any final debt repayment. In addition, this amendment promotes measures to prevent accidents or emergencies concerning radioactive materials and facilities and procedures to reduce the impact and effect of any unexpected events. Furthermore, this amendment intends to implement the concept of information transparency and public participation so as to meet the public needs. Finally, radioactive waste final disposal tasks have to be completed by waste producers under the supervision of the AEC. (authors)« less

  10. A novel fluorescence sensor based on covalent immobilization of 3-amino-9-ethylcarbazole by using silver nanoparticles as bridges and carriers.

    PubMed

    Tan, Shu-Zhen; Hu, Yan-Jun; Gong, Fu-Chun; Cao, Zhong; Xia, Jiao-Yun; Zhang, Ling

    2009-03-23

    A novel technique of covalent immobilization of indicator dyes in the preparation of fluorescence sensors is developed. Silver nanoparticles are used as bridges and carriers for anchoring indicator dyes. 3-amino-9-ethylcarbazole (AEC) was employed as an example of indicator dyes with terminal amino groups and covalently immobilized onto the outmost surface of a quartz glass slide. First, the glass slide was functionalized by (3-mercaptopropyl) trimethoxysilane (MPS) to form a thiol-terminated self-assembled monolayer, where silver nanoparticles were strongly bound to the surface through covalent bonding. Then, 16-mercaptohexadecanoic acid (MHDA) was self-assembled to bring carboxylic groups onto the surface of silver nanoparticles. A further activation by using 1-(3-dimethylaminopropyl)-3-ethylcarbodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS) converted the carboxylic groups into succinimide esters. Finally, the active succinimide esters on the surface of silver nanoparticles were reacted with AEC. Thus, AEC was covalently bound to the glass slide and an AEC-immobilized sensor was obtained. The sensor exhibited very satisfactory reproducibility and reversibility, rapid response and no dye-leaching. Rutin can quench the fluorescence intensity of the sensor and be measured by using the sensor. The linear response of the sensor to rutin covers the range from 2.0 x 10(-6) to 1.5 x 10(-4) molL(-1) with a detection limit of 8.0 x 10(-7) molL(-1). The proposed technique may be feasible to the covalent immobilization of other dyes with primary amino groups.

  11. Improved amino acid, bioenergetic metabolite and neurotransmitter profiles following human amnion epithelial cell transplant in intermediate maple syrup urine disease mice.

    PubMed

    Skvorak, Kristen J; Dorko, Kenneth; Marongiu, Fabio; Tahan, Veysel; Hansel, Marc C; Gramignoli, Roberto; Arning, Erland; Bottiglieri, Teodoro; Gibson, K Michael; Strom, Stephen C

    2013-06-01

    Orthotopic liver transplant (OLT) significantly improves patient outcomes in maple syrup urine disease (MSUD; OMIM: 248600), yet organ shortages point to the need for alternative therapies. Hepatocyte transplantation has shown both clinical and preclinical efficacy as an intervention for metabolic liver diseases, yet the availability of suitable livers for hepatocyte isolation is also limited. Conversely, human amnion epithelial cells (hAEC) may have utility as a hepatocyte substitute, and they share many of the characteristics of pluripotent embryonic stem cells while lacking their safety and ethical concerns. We reported that like hepatocytes, transplantation of hAEC significantly improved survival and lifespan, normalized body weight, and significantly improved branched-chain amino acid (BCAA) levels in sera and brain in a transgenic murine model of intermediate maple syrup urine disease (imsud). In the current report, we detail the neural and peripheral metabolic improvements associated with hAEC transplant in imsud mice, including amino acids associated with bioenergetics, the urea cycle, as well as the neurotransmitter systems for serotonin, dopamine, and gamma-aminobutyric acid (GABA). This stem cell therapy results in significant global correction of the metabolic profile that characterizes the disease, both in the periphery and the central nervous system, the target organ for toxicity in iMSUD. The significant correction of the disease phenotype, coupled with the theoretical benefits of hAEC, particularly their lack of immunogenicity and tumorigenicity, suggests that human amnion epithelial cells deserve serious consideration for clinical application to treat metabolic liver diseases. Copyright © 2013. Published by Elsevier Inc.

  12. Harold Knapp and the geography of normal controversy: radioiodine in the historical environment.

    PubMed

    Kirsch, Scott

    2004-01-01

    In 1962, after high levels of the isotope Iodine-131 were detected in Utah milk supplies, Dr. Harold Knapp, a mathematician working for the AEC's Division of Biology and Medicine, developed a new model of estimating, first, the relation between a single deposition of radioactive fallout on pasturage and the levels of Iodine-131 in fresh milk and, second, the total dose to human thyroids, resulting from daily intake of the contaminated milk. The implications of Knapp's findings were enormous. They suggested that short-living radioiodine, rather than long-living nuclides such as radiostrontium, posed the greatest hazard from nuclear test fallout and that children raised in Nevada and Utah during the 1950s had been exposed to internal radiation doses far in excess of recommended guidelines. This paper explores the explicit historical revisionism of Knapp's study, his refusal, contra normal AEC practices of knowledge production and spatial representation, to distance himself from the people and places downwind from the Nevada Test Site, and the reactions his work provoked among his AEC colleagues.

  13. PLUTONIUM ALLOYS CONTAINING CONTROLLED AMOUNTS OF PLUTONIUM ALLOTROPES OBTAINED BY APPLICATION OF HIGH PRESSURES

    DOEpatents

    Elliott, R.O.; Gschneidner, K.A. Jr.

    1962-07-10

    A method of making stabilized plutonium alloys which are free of voids and cracks and have a controlled amount of plutonium allotropes is described. The steps include adding at least 4.5 at.% of hafnium, indium, or erbium to the melted plutonium metal, homogenizing the resulting alloy at a temperature of 450 deg C, cooling to room temperature, and subjecting the alloy to a pressure which produces a rapid increase in density with a negligible increase in pressure. The pressure required to cause this rapid change in density or transformation ranges from about 800 to 2400 atmospheres, and is dependent on the alloying element. (AEC)

  14. Detectability comparison between a high energy x-ray phase sensitive and mammography systems in imaging phantoms with varying glandular-adipose ratios

    NASA Astrophysics Data System (ADS)

    Ghani, Muhammad U.; Wong, Molly D.; Wu, Di; Zheng, Bin; Fajardo, Laurie L.; Yan, Aimin; Fuh, Janis; Wu, Xizeng; Liu, Hong

    2017-05-01

    The objective of this study was to demonstrate the potential benefits of using high energy x-rays in comparison with the conventional mammography imaging systems for phase sensitive imaging of breast tissues with varying glandular-adipose ratios. This study employed two modular phantoms simulating the glandular (G) and adipose (A) breast tissue composition in 50 G-50 A and 70 G-30 A percentage densities. Each phantom had a thickness of 5 cm with a contrast detail test pattern embedded in the middle. For both phantoms, the phase contrast images were acquired using a micro-focus x-ray source operated at 120 kVp and 4.5 mAs, with a magnification factor (M) of 2.5 and a detector with a 50 µm pixel pitch. The mean glandular dose delivered to the 50 G-50 A and 70 G-30 A phantom sets were 1.33 and 1.3 mGy, respectively. A phase retrieval algorithm based on the phase attenuation duality that required only a single phase contrast image was applied. Conventional low energy mammography images were acquired using GE Senographe DS and Hologic Selenia systems utilizing their automatic exposure control (AEC) settings. In addition, the automatic contrast mode (CNT) was also used for the acquisition with the GE system. The AEC mode applied higher dose settings for the 70 G-30 A phantom set. As compared to the phase contrast images, the dose levels for the AEC mode acquired images were similar while the dose levels for the CNT mode were almost double. The observer study, contrast-to-noise ratio and figure of merit comparisons indicated a large improvement with the phase retrieved images in comparison to the AEC mode images acquired with the clinical systems for both density levels. As the glandular composition increased, the detectability of smaller discs decreased with the clinical systems, particularly with the GE system, even at higher dose settings. As compared to the CNT mode (double dose) images, the observer study also indicated that the phase retrieved images provided similar or improved detection for all disc sizes except for the disk diameters of 2 mm and 1 mm for the 50 G-50 A phantom and 3 mm and 0.5 mm for the 70 G-30 A phantom. This study demonstrated the potential of utilizing a high energy phase sensitive x-ray imaging system to improve lesion detection and reduce radiation dose when imaging breast tissues with varying glandular compositions.

  15. Amniotic Mesenchymal Stromal Cells Exhibit Preferential Osteogenic and Chondrogenic Differentiation and Enhanced Matrix Production Compared With Adipose Mesenchymal Stromal Cells.

    PubMed

    Topoluk, Natasha; Hawkins, Richard; Tokish, John; Mercuri, Jeremy

    2017-09-01

    Therapeutic efficacy of various mesenchymal stromal cell (MSC) types for orthopaedic applications is currently being investigated. While the concept of MSC therapy is well grounded in the basic science of healing and regeneration, little is known about individual MSC populations in terms of their propensity to promote the repair and/or regeneration of specific musculoskeletal tissues. Two promising MSC sources, adipose and amnion, have each demonstrated differentiation and extracellular matrix (ECM) production in the setting of musculoskeletal tissue regeneration. However, no study to date has directly compared the differentiation potential of these 2 MSC populations. To compare the ability of human adipose- and amnion-derived MSCs to undergo osteogenic and chondrogenic differentiation. Controlled laboratory study. MSC populations from the human term amnion were quantified and characterized via cell counting, histologic assessment, and flow cytometry. Differentiation of these cells in comparison to commercially purchased human adipose-derived mesenchymal stromal cells (hADSCs) in the presence and absence of differentiation media was evaluated via reverse transcription polymerase chain reaction (PCR) for bone and cartilage gene transcript markers and histology/immunohistochemistry to examine ECM production. Analysis of variance and paired t tests were performed to compare results across all cell groups investigated. The authors confirmed that the human term amnion contains 2 primary cell types demonstrating MSC characteristics-(1) human amniotic epithelial cells (hAECs) and (2) human amniotic mesenchymal stromal cells (hAMSCs)-and each exhibited more than 90% staining for MSC surface markers (CD90, CD105, CD73). Average viable hAEC and hAMSC yields at harvest were 2.3 × 10 6 ± 3.7 × 10 5 and 1.6 × 10 6 ± 4.7 × 10 5 per milliliter of amnion, respectively. As well, hAECs and hAMSCs demonstrated significantly greater osteocalcin ( P = .025), aggrecan ( P < .0001), and collagen type 2 ( P = .044) gene expression compared with hADSCs, respectively, after culture in differentiation medium. Moreover, both hAECs and hAMSCs produced significantly greater quantities of mineralized ( P < .0001) and cartilaginous ( P = .0004) matrix at earlier time points compared with hADSCs when cultured under identical osteogenic and chondrogenic differentiation conditions, respectively. Amnion-derived MSCs demonstrate a greater differentiation potential toward bone and cartilage compared with hADSCs. Amniotic MSCs may be the source of choice in the regenerative treatment of bone or osteochondral musculoskeletal disease. They show significantly higher yields and better differentiation toward these tissues than MSCs derived from adipose.

  16. Radiation dose exposure in patients affected by lymphoma undergoing repeat CT examinations: how to manage the radiation dose variability.

    PubMed

    Paolicchi, Fabio; Bastiani, Luca; Guido, Davide; Dore, Antonio; Aringhieri, Giacomo; Caramella, Davide

    2018-03-01

    To assess the variability of radiation dose exposure in patients affected by lymphoma undergoing repeat CT (computed tomography) examinations and to evaluate the influence of different scan parameters on the overall radiation dose. A series of 34 patients (12 men and 22 women with a median age of 34.4 years) with lymphoma, after the initial staging CT underwent repeat follow-up CT examinations. For each patient and each repeat examination, age, sex, use of AEC system (Automated Exposure Control, i.e. current modulation), scan length, kV value, number of acquired scans (i.e. number of phases), abdominal size diameter and dose length product (DLP) were recorded. The radiation dose of just one venous phase was singled out from the DLP of the entire examination. All scan data were retrieved by our PACS (Picture Archiving and Communication System) by means of a dose monitoring software. Among the variables we considered, no significant difference of radiation dose was observed among patients of different ages nor concerning tube voltage. On the contrary the dose delivered to the patients varied depending on sex, scan length and usage of AEC. No significant difference was observed depending on the behaviour of technologists, while radiologists' choices had indirectly an impact on the radiation dose due to the different number of scans requested by each of them. Our results demonstrate that patients affected by lymphoma who undergo repeat whole body CT scanning may receive unnecessary overexposure. We quantified and analyzed the most relevant variables in order to provide a useful tool to manage properly CT dose variability, estimating the amount of additional radiation dose for every single significant variable. Additional scans, incorrect scan length and incorrect usage of AEC system are the most relevant cause of patient radiation exposure.

  17. SU-E-I-91: Reproducibility in Prescribed Dose in AEC CT Scans Due to Table Height, Patient Size, and Localizer Acquisition Order

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Winslow, J; Hurwitz, L; Christianson, O

    2014-06-01

    Purpose: In CT scanners, the automatic exposure control (AEC) tube current prescription depends on the acquired prescan localizer image(s). The purpose of this study was to quantify the effect that table height, patient size, and localizer acquisition order may have on the reproducibility in prescribed dose. Methods: Three phantoms were used for this study: the Mercury Phantom (comprises three tapered and four uniform regions of polyethylene 16, 23, 30, and 37 cm in diameter), acrylic sheets, and an adult anthropomorphic phantom. Phantoms were positioned per clinical protocol by our chief CT technologist or broader symmetry. Using a GE Discovery CT750HDmore » scanner, a lateral (LAT) and posterior-anterior (PA) localizer was acquired for each phantom at different table heights. AEC scan acquisitions were prescribed for each combination of phantom, localizer orientation, and table height; the displayed volume CTDI was recorded for each. Results were analyzed versus table height. Results: For the two largest Mercury Phantom section scans based on the PA localizer, the percent change in volume CTDI from ideal were at least 20% lower and 35% greater for table heights 4 cm above and 4 cm below proper centering, respectively. For scans based on the LAT localizer, the percent change in volume CTDI from ideal were no greater than 12% different for 4 cm differences in table height. The properly centered PA and LAT localizer-based volume CTDI values were within 13% of each other. Conclusion: Since uncertainty in vertical patient positioning is inherently greater than lateral positioning and because the variability in dose exceeds any dose penalties incurred, the LAT localizer should be used to precisely and reproducibly deliver the intended amount of radiation prescribed by CT protocols. CT protocols can be adjusted to minimize the expected change in average patient dose.« less

  18. TH-C-18A-06: Combined CT Image Quality and Radiation Dose Monitoring Program Based On Patient Data to Assess Consistency of Clinical Imaging Across Scanner Models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christianson, O; Winslow, J; Samei, E

    2014-06-15

    Purpose: One of the principal challenges of clinical imaging is to achieve an ideal balance between image quality and radiation dose across multiple CT models. The number of scanners and protocols at large medical centers necessitates an automated quality assurance program to facilitate this objective. Therefore, the goal of this work was to implement an automated CT image quality and radiation dose monitoring program based on actual patient data and to use this program to assess consistency of protocols across CT scanner models. Methods: Patient CT scans are routed to a HIPPA compliant quality assurance server. CTDI, extracted using opticalmore » character recognition, and patient size, measured from the localizers, are used to calculate SSDE. A previously validated noise measurement algorithm determines the noise in uniform areas of the image across the scanned anatomy to generate a global noise level (GNL). Using this program, 2358 abdominopelvic scans acquired on three commercial CT scanners were analyzed. Median SSDE and GNL were compared across scanner models and trends in SSDE and GNL with patient size were used to determine the impact of differing automatic exposure control (AEC) algorithms. Results: There was a significant difference in both SSDE and GNL across scanner models (9–33% and 15–35% for SSDE and GNL, respectively). Adjusting all protocols to achieve the same image noise would reduce patient dose by 27–45% depending on scanner model. Additionally, differences in AEC methodologies across vendors resulted in disparate relationships of SSDE and GNL with patient size. Conclusion: The difference in noise across scanner models indicates that protocols are not optimally matched to achieve consistent image quality. Our results indicated substantial possibility for dose reduction while achieving more consistent image appearance. Finally, the difference in AEC methodologies suggests the need for size-specific CT protocols to minimize variability in image quality across CT vendors.« less

  19. Over-exposure correction in knee cone-beam CT imaging with automatic exposure control using a partial low dose scan

    NASA Astrophysics Data System (ADS)

    Choi, Jang-Hwan; Muller, Kerstin; Hsieh, Scott; Maier, Andreas; Gold, Garry; Levenston, Marc; Fahrig, Rebecca

    2016-03-01

    C-arm-based cone-beam CT (CBCT) systems with flat-panel detectors are suitable for diagnostic knee imaging due to their potentially flexible selection of CT trajectories and wide volumetric beam coverage. In knee CT imaging, over-exposure artifacts can occur because of limitations in the dynamic range of the flat panel detectors present on most CBCT systems. We developed a straightforward but effective method for correction and detection of over-exposure for an Automatic Exposure Control (AEC)-enabled standard knee scan incorporating a prior low dose scan. The radiation dose associated with the low dose scan was negligible (0.0042mSv, 2.8% increase) which was enabled by partially sampling the projection images considering the geometry of the knees and lowering the dose further to be able to just see the skin-air interface. We combined the line integrals from the AEC and low dose scans after detecting over-exposed regions by comparing the line profiles of the two scans detector row-wise. The combined line integrals were reconstructed into a volumetric image using filtered back projection. We evaluated our method using in vivo human subject knee data. The proposed method effectively corrected and detected over-exposure, and thus recovered the visibility of exterior tissues (e.g., the shape and density of the patella, and the patellar tendon), incorporating a prior low dose scan with a negligible increase in radiation exposure.

  20. Long-Term Surveillance and Maintenance Plan for the U.S. Department of Energy Amchitka, Alaska, Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2008-09-01

    This Long-Term Surveillance and Maintenance Plan describes how the U.S. Department of Energy (DOE) intends to fulfill its mission to maintain protection of human health and the environment at the Amchitka, Alaska, Site1. Three underground nuclear tests were conducted on Amchitka Island. The U.S. Department of Defense, in conjunction with the U.S. Atomic Energy Commission (AEC), conducted the first nuclear test (Long Shot) to provide data that would improve the United States' capability of detecting underground nuclear explosions. The second nuclear test (Milrow) was a weapons-related test conducted by AEC as a means to study the feasibility of detonating amore » much larger device. The final nuclear test (Cannikin), the largest United States underground test, was a weapons-related test. Surface disturbances associated with these tests have been remediated. However, radioactivity remains deep below the surface, contained in and around the test cavities, for which no feasible remediation technology has been identified. In 2006, the groundwater model (Hassan et al. 2002) was updated using 2005 data collected by the Consortium for Risk Evaluation with Stakeholder Participation. Model simulation results indicate there is no breakthrough or seepage of radionuclides into the marine environment within 2,000 years. The Amchitka conceptual model is reasonable; the flow and transport simulation is based on the best available information and data. The simulation results are a quantitative prediction supported by the best available science and technology. This Long-Term Surveillance and Maintenance Plan is an additional step intended for the protection of human health and the environment. This plan may be modified from time to time in the future consistent with the mission to protect human health« less

  1. Antifungal Treatment is Not Required for Immunocompetent Individuals With Asymptomatic Esophageal Candidiasis.

    PubMed

    Min, Yang Won; Kim, Eun; Son, Hee Jung; Kim, Jae J; Rhee, Poong-Lyul

    2015-11-01

    Although esophageal candidiasis (EC) is an opportunistic infection, asymptomatic EC (AEC) is occasionally encountered in otherwise healthy individuals. This study evaluates the impact of antifungal treatment in immunocompetent individuals with AEC and investigates risk factors for persistent or recurrent EC. The authors identified patients with biopsy-proven AEC from the database of individuals receiving screening endoscopy (n = 99,255). After excluding patients receiving immunosuppressive therapy, being positive for human immunodeficiency virus, receiving no follow-up endoscopy, or having no antifungal treatment data, a total of 142 patients were divided into remission and nonremission groups. Remission was defined when EC was not detectable on follow-up endoscopy. On baseline comparison, nonremission group was older (57.5 ± 10.3 versus 52.5 ± 10.5 years, P = 0.017) and more likely to have cardiovascular disease (12.9% versus 1.8%, P = 0.021) and history of pulmonary tuberculosis (PTB) (22.6% versus 4.5%, P = 0.004) and exhibited a lower triglyceride level (101.4 ± 37.4 versus 122.6 ± 79.6 mg/dL, P = 0.039) than remission group, whereas grade of EC and concomitant endoscopic findings did not differ between 2 groups. Antifungal treatment was also similarly performed between 2 groups. Multivariate analysis revealed that history of PTB is independently associated with nonremission (odds ratio 4.495, 95% confidence interval 1.023-19.762, P = 0.047). No patients demonstrated EC-related complications during a mean follow-up of 28.0 ± 12.0 months. In conclusion, our results suggested that antifungal treatment is not required for immunocompetent individuals with AEC and past history of PTB is an independent predictor for persistent or recurrent EC.

  2. Differential antiviral activities of respiratory syncytial virus (RSV) inhibitors in human airway epithelium.

    PubMed

    Mirabelli, Carmen; Jaspers, Martine; Boon, Mieke; Jorissen, Mark; Koukni, Mohamed; Bardiot, Dorothée; Chaltin, Patrick; Marchand, Arnaud; Neyts, Johan; Jochmans, Dirk

    2018-03-27

    We report the use of reconstituted 3D human airway epithelium cells (HuAECs) of bronchial origin in an air-liquid interface to study respiratory syncytial virus (RSV) infection and to assess the efficacy of RSV inhibitors in (pre-)clinical development. HuAECs were infected with RSV-A Long strain (0.01 CCID50/cell, where CCID50 represents 50% cell culture infectious dose in HEp2 cells) on the apical compartment of the culture. At the time of infection or at 1 or 3 days post-infection, selected inhibitors were added and refreshed daily on the basal compartment of the culture. Viral shedding was followed up by apical washes collected daily and quantifying viral RNA by RT-qPCR. RSV-A replicates efficiently in HuAECs and viral RNA is shed for weeks after infection. RSV infection reduces the ciliary beat frequency of the ciliated cells as of 4 days post-infection, with complete ciliary dyskinesia observed by day 10. Treatment with RSV fusion inhibitors resulted in an antiviral effect only when added at the time of infection. In contrast, the use of replication inhibitors (both nucleoside and non-nucleoside) elicited a marked antiviral effect even when the start of treatment was delayed until 1 day or even 3 days after infection. Levels of the inflammation marker RANTES (mRNA) increased ∼200-fold in infected, untreated cultures (at 3 weeks post-infection), but levels were comparable to those of uninfected cultures in the presence of PC786, an RSV replication inhibitor, suggesting that an efficient antiviral treatment might inhibit virus-induced inflammation in this model. Overall, HuAECs offer a robust and physiologically relevant model to study RSV replication and to assess the efficacy of antiviral compounds.

  3. Quorum Sensing Down-Regulation Counteracts the Negative Impact of Pseudomonas aeruginosa on CFTR Channel Expression, Function and Rescue in Human Airway Epithelial Cells

    PubMed Central

    Maillé, Émilie; Ruffin, Manon; Adam, Damien; Messaoud, Hatem; Lafayette, Shantelle L.; McKay, Geoffrey; Nguyen, Dao; Brochiero, Emmanuelle

    2017-01-01

    The function of cystic fibrosis transmembrane conductance regulator (CFTR) channels is crucial in human airways. However unfortunately, chronic Pseudomonas aeruginosa infection has been shown to impair CFTR proteins in non-CF airway epithelial cells (AEC) and to alter the efficiency of new treatments with CFTR modulators designed to correct the basic CFTR default in AEC from cystic fibrosis (CF) patients carrying the F508del mutation. Our aim was first to compare the effect of laboratory strains, clinical isolates, engineered and natural mutants to determine the role of the LasR quorum sensing system in CFTR impairment, and second, to test the efficiency of a quorum sensing inhibitor to counteract the deleterious impact of P. aeruginosa both on wt-CFTR and on the rescue of F508del-CFTR by correctors. We first report that exoproducts from either the laboratory PAO1 strain or a clinical ≪Early≫ isolate (from an early stage of infection) altered CFTR expression, localization and function in AEC expressing wt-CFTR. Genetic inactivation of the quorum-sensing LasR in PAO1 (PAO1ΔlasR) or in a natural clinical mutant (≪Late≫ CF-adapted clinical isolate) abolished wt-CFTR impairment. PAO1 exoproducts also dampened F508del-CFTR rescue by VRT-325 or Vx-809 correctors in CF cells, whereas PAO1ΔlasR had no impact. Importantly, treatment of P. aeruginosa cultures with a quorum sensing inhibitor (HDMF) prevented the negative effect of P. aeruginosa exoproducts on wt-CFTR and preserved CFTR rescue by correctors in CF AEC. These findings indicate that LasR-interfering strategies could be of benefits to counteract the deleterious effect of P. aeruginosa in infected patients. PMID:29177135

  4. Airway delivery of mesenchymal stem cells prevents arrested alveolar growth in neonatal lung injury in rats.

    PubMed

    van Haaften, Timothy; Byrne, Roisin; Bonnet, Sebastien; Rochefort, Gael Y; Akabutu, John; Bouchentouf, Manaf; Rey-Parra, Gloria J; Galipeau, Jacques; Haromy, Alois; Eaton, Farah; Chen, Ming; Hashimoto, Kyoko; Abley, Doris; Korbutt, Greg; Archer, Stephen L; Thébaud, Bernard

    2009-12-01

    Bronchopulmonary dysplasia (BPD) and emphysema are characterized by arrested alveolar development or loss of alveoli; both are significant global health problems and currently lack effective therapy. Bone marrow-derived mesenchymal stem cells (BMSCs) prevent adult lung injury, but their therapeutic potential in neonatal lung disease is unknown. We hypothesized that intratracheal delivery of BMSCs would prevent alveolar destruction in experimental BPD. In vitro, BMSC differentiation and migration were assessed using co-culture assays and a modified Boyden chamber. In vivo, the therapeutic potential of BMSCs was assessed in a chronic hyperoxia-induced model of BPD in newborn rats. In vitro, BMSCs developed immunophenotypic and ultrastructural characteristics of type II alveolar epithelial cells (AEC2) (surfactant protein C expression and lamellar bodies) when co-cultured with lung tissue, but not with culture medium alone or liver. Migration assays revealed preferential attraction of BMSCs toward oxygen-damaged lung versus normal lung. In vivo, chronic hyperoxia in newborn rats led to air space enlargement and loss of lung capillaries, and this was associated with a decrease in circulating and resident lung BMSCs. Intratracheal delivery of BMSCs on Postnatal Day 4 improved survival and exercise tolerance while attenuating alveolar and lung vascular injury and pulmonary hypertension. Engrafted BMSCs coexpressed the AEC2-specific marker surfactant protein C. However, engraftment was disproportionately low for cell replacement to account for the therapeutic benefit, suggesting a paracrine-mediated mechanism. In vitro, BMSC-derived conditioned medium prevented O(2)-induced AEC2 apoptosis, accelerated AEC2 wound healing, and enhanced endothelial cord formation. BMSCs prevent arrested alveolar and vascular growth in part through paracrine activity. Stem cell-based therapies may offer new therapeutic avenues for lung diseases that currently lack efficient treatments.

  5. RADIATION SHIELDING COMPOSITION

    DOEpatents

    Dunegan, H.L.

    1963-01-29

    A light weight radiation shielding composition is described whose mechanical and radiological properties can be varied within wide limits. The composition of this shielding material consists of four basic ingredients: powder of either Pb or W, a plastic resin, a resin plasticizer, and a polymerization catalyst to promote an interaction of the plasticizer with the plastic resin. Air may be mixed into the above ingredients in order to control the density of the final composition. For equivalent gamma attenuation, the shielding composition weighs one-third to one-half as much as conventional Pb shielding. (AEC)

  6. REFLECTOR CONTROL OF A BOILING-WATER REACTOR

    DOEpatents

    Treshow, M.

    1962-05-22

    A line connecting the reactor with a spent steam condenser contains a valve set to open when the pressure in the reactor exceeds a predetermined value and an orifice on the upstream side of the valve. Another line connects the reflector with this line between the orifice and the valve. An excess steam pressure causes the valve to open and the flow of steam through the line draws water out of the reflector. Provision is also made for adding water to the reflector when the steam pressure drops. (AEC)

  7. RADIATION FACILITY FOR NUCLEAR REACTORS

    DOEpatents

    Currier, E.L. Jr.; Nicklas, J.H.

    1961-12-12

    A radiation facility is designed for irradiating samples in close proximity to the core of a nuclear reactor. The facility comprises essentially a tubular member extending through the biological shield of the reactor and containing a manipulatable rod having the sample carrier at its inner end, the carrier being longitudinally movable from a position in close proximity to the reactor core to a position between the inner and outer faces of the shield. Shield plugs are provided within the tubular member to prevent direct radiation from the core emanating therethrough. In this device, samples may be inserted or removed during normal operation of the reactor without exposing personnel to direct radiation from the reactor core. A storage chamber is also provided within the radiation facility to contain an irradiated sample during the period of time required to reduce the radioactivity enough to permit removal of the sample for external handling. (AEC)

  8. ERROR COMPENSATOR FOR A POSITION TRANSDUCER

    DOEpatents

    Fowler, A.H.

    1962-06-12

    A device is designed for eliminating the effect of leadscrew errors in positioning machines in which linear motion of a slide is effected from rotary motion of a leadscrew. This is accomplished by providing a corrector cam mounted on the slide, a cam follower, and a transducer housing rotatable by the follower to compensate for all the reproducible errors in the transducer signal which can be related to the slide position. The transducer has an inner part which is movable with respect to the transducer housing. The transducer inner part is coupled to the means for rotating the leadscrew such that relative movement between this part and its housing will provide an output signal proportional to the position of the slide. The corrector cam and its follower perform the compensation by changing the angular position of the transducer housing by an amount that is a function of the slide position and the error at that position. (AEC)

  9. RESONATOR PARTICLE SEPARATOR

    DOEpatents

    Blewett, J.P.

    1962-01-01

    A wave guide resonator structure is described for use in separating particles of equal momentum but differing in mass and having energies exceeding one billion electron volts. The particles are those of sub-atomic size and are generally produced as a result of the bombardment of a target by a beam such as protons produced in a high-energy accelerator. In this wave guide construction, the particles undergo preferential deflection as a result of the presence of an electric field. The boundary conditions established in the resonator are such as to eliminate an interfering magnetic component, and to otherwise phase the electric field to obtain a traveling wave such as one which moves at the same speed as the unwanted particle. The latter undergoes continuous deflection over the whole length of the device and is, therefore, eliminated while the wanted particle is deflected in opposite directions over the length of the resonator and is thus able to enter an exit aperture. (AEC)

  10. Evidence for the involvement of cofilin in Aspergillus fumigatus internalization into type II alveolar epithelial cells.

    PubMed

    Bao, Zhiyao; Han, Xuelin; Chen, Fangyan; Jia, Xiaodong; Zhao, Jingya; Zhang, Changjian; Yong, Chen; Tian, Shuguang; Zhou, Xin; Han, Li

    2015-08-13

    The internalization of Aspergillus fumigatus into alveolar epithelial cells (AECs) is tightly controlled by host cellular actin dynamics, which require close modulation of the ADF (actin depolymerizing factor)/cofilin family. However, the role of cofilin in A. fumigatus internalization into AECs remains unclear. Here, we demonstrated that germinated A. fumigatus conidia were able to induce phosphorylation of cofilin in A549 cells during the early stage of internalization. The modulation of cofilin activity by overexpression, knockdown, or mutation of the cofilin gene in A549 cells decreased the efficacy of A. fumigatus internalization. Reducing the phosphorylation status of cofilin with BMS-5 (LIM kinase inhibitor) or overexpression of the slingshot phosphatases also impeded A. fumigatus internalization. Both the C. botulimun C3 transferase (a specific RhoA inhibitor) and Y27632 (a specific ROCK inhibitor) reduced the internalization of A. fumigatus and the level of phosphorylated cofilin. β-1,3-glucan (the major component of the conidial cell wall) and its host cell receptor dectin-1 did not seem to be associated with cofilin phosphorylation during A. fumigatus infection. These results indicated that cofilin might be involved in the modulation of A. fumigatus internalization into type II alveolar epithelial cells through the RhoA-ROCK-LIM kinase pathway.

  11. Minutes of the Explosives Safety Seminar (16th), Held at the Diplomat Hotel, Hollywood, Florida on 24-26 September 1974. Volume 2

    DTIC Science & Technology

    1974-09-26

    concrete structi-e at Battelle Memorial Labs are on hand. b, Photos and drawing of 10’ ID X 31’ steel test chamber 𔃻: Los Alamos . c. Tech data or, AEC... Technical Report, Draft. 3. M0TT, R.l., "A Theory of Fuauentation", Army Operational Research Group Ho., 113-AC-3642, Great Britain, 1943 . 4. GUI , R.W., "he...Kansas AAP, Parsons, KSBURCH, Austin AEC, Los Alamos , NMBURKE, E. F. Olin Corp., St. Marks, FLBURNER, M R. DCASR, N.Y., NYBURNS, N.J3. Dept of

  12. The history, development and the present status of the radon measurement programme in the United States of America.

    PubMed

    George, A C

    2015-11-01

    The US radon measurement programme began in the late 1950s by the US Public Health Service in Colorado, New Mexico and Utah during the uranium frenzy. After the 1967 Congressional Hearings on the working conditions in uranium mines, the US Atomic Energy Commission (AEC) was asked to conduct studies in active uranium mines to assess the exposure of the miners on the Colorado Plateau and in New Mexico. From 1967 to 1972, the Health and Safety Laboratory of the US AEC in New York investigated more than 20 uranium mines for radon and radon decay product concentrations and particle size in 4 large uranium mines in New Mexico. In 1970, the US Environmental Protection Agency (EPA) was established and took over some of the AEC radon measurement activities. Between 1975 and 1978, the Environmental Measurements Laboratory of the US Department of Energy conducted the first detailed indoor radon survey in the USA. Later in 1984, the very high concentrations of radon found in Pennsylvania homes set the wheels in motion and gave birth to the US Radon Industry. The US EPA expanded its involvement in radon issues and assumed an active role by establishing the National Radon Proficiency Program to evaluate the effectiveness of radon measurement and mitigation methods. In 1998, due to limited resources EPA privatised the radon programme. This paper presents a personal perspective of past events and current status of the US radon programme. It will present an update on radon health effects, the incidence rate of lung cancer in the USA and the number of radon measurements made from 1988 to 2013 using short-term test methods. More than 23 million measurements were made in the last 25 y and as a result more than 1.24 million homes were mitigated successfully. It is estimated that <2 % of the radon measurements performed in the USA are made using long-term testing devices. The number of homes above the US action level of 148 Bq m(-3) (4 pCi l(-1)) may be ∼8.5 million because ∼50 million homes were added since 1990 to the home inventory. This paper will discuss the current instruments and methods used to measure radon in the USA, and what is the effectiveness of radon resistant new construction, the current status of mitigation standards and the proposed testing protocols in schools and large buildings. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Nerve signaling regulates basal keratinocyte proliferation in the blastema apical epithelial cap in the axolotl (Ambystoma mexicanum).

    PubMed

    Satoh, Akira; Bryant, Susan V; Gardiner, David M

    2012-06-15

    The ability of adult vertebrates to repair tissue damage is widespread and impressive; however, the ability to regenerate structurally complex organs such as the limb is limited largely to the salamanders. The fact that most of the tissues of the limb can regenerate has led investigators to question and identify the barriers to organ regeneration. From studies in the salamander, it is known that one of the earliest steps required for successful regeneration involves signaling between nerves and the wound epithelium/apical epithelial cap (AEC). In this study we confirm an earlier report that the keratinocytes of the AEC acquire their function coincident with exiting the cell cycle. We have discovered that this unique, coordinated behavior is regulated by nerve signaling and is associated with the presence of gap junctions between the basal keratinocytes of the AEC. Disruption of nerve signaling results in a loss of gap junction protein, the reentry of the cells into the cell cycle, and regenerative failure. Finally, coordinated exit from the cell cycle appears to be a conserved behavior of populations of cells that function as signaling centers during both development and regeneration. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. Neutron diffraction study of water freezing on aircraft engine combustor soot.

    PubMed

    Tishkova, V; Demirdjian, B; Ferry, D; Johnson, M

    2011-12-14

    The study of the formation of condensation trails and cirrus clouds on aircraft emitted soot particles is important because of its possible effects on climate. In the present work we studied the freezing of water on aircraft engine combustor (AEC) soot particles under conditions of pressure and temperature similar to the upper troposphere. The microstructure of the AEC soot was found to be heterogeneous containing both primary particles of soot and metallic impurities (Fe, Cu, and Al). We also observed various surface functional groups such as oxygen-containing groups, including sulfate ions, that can act as active sites for water adsorption. Here we studied the formation of ice on the AEC soot particles by using neutron diffraction. We found that for low amount of adsorbed water, cooling even up to 215 K did not lead to the formation of hexagonal ice. Whereas, larger amount of adsorbed water led to the coexistence of liquid water (or amorphous ice) and hexagonal ice (I(h)); 60% of the adsorbed water was in the form of ice I(h) at 255 K. Annealing of the system led to the improvement of the crystal quality of hexagonal ice crystals as demonstrated from neutron diffraction.

  15. Demonstration of array eddy current technology for real-time monitoring of laser powder bed fusion additive manufacturing process

    NASA Astrophysics Data System (ADS)

    Todorov, Evgueni; Boulware, Paul; Gaah, Kingsley

    2018-03-01

    Nondestructive evaluation (NDE) at various fabrication stages is required to assure quality of feedstock and solid builds. Industry efforts are shifting towards solutions that can provide real-time monitoring of additive manufacturing (AM) fabrication process layer-by-layer while the component is being built to reduce or eliminate dependence on post-process inspection. Array eddy current (AEC), electromagnetic NDE technique was developed and implemented to directly scan the component without physical contact with the powder and fused layer surfaces at elevated temperatures inside a LPBF chamber. The technique can detect discontinuities, surface irregularities, and undesirable metallurgical phase transformations in magnetic and nonmagnetic conductive materials used for laser fusion. The AEC hardware and software were integrated with the L-PBF test bed. Two layer-by-layer tests of Inconel 625 coupons with AM built discontinuities and lack of fusion were conducted inside the L-PBF chamber. The AEC technology demonstrated excellent sensitivity to seeded, natural surface, and near-surface-embedded discontinuities, while also detecting surface topography. The data was acquired and imaged in a layer-by-layer sequence demonstrating the real-time monitoring capabilities of this new technology.

  16. A comparison of physiological indicators of sublethal cadmium stress in wetland plants

    USGS Publications Warehouse

    Mendelssohn, I.A.; McKee, K.L.; Kong, T.

    2001-01-01

    Physiological indices, including photosynthesis, chlorophyll fluorescence, adenylate energy charge (AEC) ratio, and leaf reflectance, were determined for Typha domingensis and Spartina alterniflora in response to increasing concentrations of Cd and compared with the growth responses of these species. Leaf expansion, the live/total ratio of plant aboveground biomass, and the aboveground regrowth rate after the initial harvests were significantly reduced with increasing Cd concentration in the growth medium. Of the four physiological responses measured, only photosynthesis and AEC responded to the Cd treatment before damage was visually apparent. Also, these indices were significantly correlated with leaf expansion rate and live/total ratio in most instances. Except at the end of the experiment, when the most stressed plants began to die, the Fv/Fm ratio was not significantly affected by the Cd treatment. The leaf spectral reflectance parameters showed no significant change during the entire treatment period. The significant correlation between the stress indicators and plant growth supported the findings that photosynthesis and AEC were the most responsive of the indicators tested, however, further research investigating other chlorophyll fluorescence and leaf reflectance parameters may demonstrate as well the value of these indicators in quantifying sublethal stress. ?? 2001 Elsevier Science B.V. All rights reserved.

  17. CasCADe: A Novel 4D Visualization System for Virtual Construction Planning.

    PubMed

    Ivson, Paulo; Nascimento, Daniel; Celes, Waldemar; Barbosa, Simone Dj

    2018-01-01

    Building Information Modeling (BIM) provides an integrated 3D environment to manage large-scale engineering projects. The Architecture, Engineering and Construction (AEC) industry explores 4D visualizations over these datasets for virtual construction planning. However, existing solutions lack adequate visual mechanisms to inspect the underlying schedule and make inconsistencies readily apparent. The goal of this paper is to apply best practices of information visualization to improve 4D analysis of construction plans. We first present a review of previous work that identifies common use cases and limitations. We then consulted with AEC professionals to specify the main design requirements for such applications. These guided the development of CasCADe, a novel 4D visualization system where task sequencing and spatio-temporal simultaneity are immediately apparent. This unique framework enables the combination of diverse analytical features to create an information-rich analysis environment. We also describe how engineering collaborators used CasCADe to review the real-world construction plans of an Oil & Gas process plant. The system made evident schedule uncertainties, identified work-space conflicts and helped analyze other constructability issues. The results and contributions of this paper suggest new avenues for future research in information visualization for the AEC industry.

  18. Preliminary report on the geology, geophysics and hydrology of USBM/AEC Colorado core hole No. 2, Piceance Creek Basin, Rio Blanco County, Colorado

    USGS Publications Warehouse

    Ege, J.R.; Carroll, R.D.; Welder, F.A.

    1967-01-01

    Approximately 1,400 feet of continuous core was taken .between 800-2,214 feet in depth from USBM/AEC Colorado core hole No. 2. The drill, site is located in the Piceance Creek basin, Rio Blanco County, Colorado. From ground surface the drill hole penetrated 1,120 feet of the Evacuation Creek Member and 1,094 feet of oil shale in the Parachute Creek Member of the Green River Formation. Oil shale yielding more than 20 gallons per ton occurs between 1,260-2,214 feet in depth. A gas explosion near the bottom of the hole resulted in abandonment of the exploratory hole which was still in oil shale. The top of the nahcolite zone is at 1,693 feet. Below this depth the core contains common to abundant amounts of sodium bicarbonate salt intermixed with oil shale. The core is divided into seven structural zones that reflect changes in joint intensity, core loss and broken core due to natural causes. The zone of poor core recovery is in the Interval between 1,300-1,450 feet. Results of preliminary geophysical log analyses indicate that oil yields determined by Fischer assay compare favorably with yields determined by geophysical log analyses. There is strong evidence that analyses of complete core data from Colorado core holes No. 1 and No. 2 reveal a reliable relationship between geophysical log response and oil yield. The quality of the logs is poor in the rich shale section and the possibility of repeating the logging program should be considered. Observations during drilling, coring, and hydrologic testing of USBM/AEC Colorado core hole No. 2 reveal that the Parachute Creek Member of the Green River Formation is the principal aquifer water in the Parachute Creek Member is under artesian pressure. The upper part of the aquifer has a higher hydrostatic head than, and is hydrologically separated from the lower part of the aquifer. The transmissibility of the aquifer is about 3500 gpd per foot. The maximum water yield of the core hole during testing was about 500 gpm. Chemical analyses of water samples indicate that the content of dissolved solids is low, the principal ions being sodium and bicarbonate. Although the hole was originally cored, to a depth of 2,214 feet, ,the present depth is about 2,100 feet. This report presents a preliminary evaluation of core examination, geophysical log interpretation and hydrological tests from the USBM/AEC Colorado core hole No. 2. The cooperation of the U.S. Bureau of Mines is gratefully acknowledged. The reader is referred to Carroll and others (1967) for comparison of USBM/AEC Col0rado core hole No. 1 with USBM/AEC Colorado core hole No. 2.

  19. Quality assurance and quality control in mammography: a review of available guidance worldwide.

    PubMed

    Reis, Cláudia; Pascoal, Ana; Sakellaris, Taxiarchis; Koutalonis, Manthos

    2013-10-01

    Review available guidance for quality assurance (QA) in mammography and discuss its contribution to harmonise practices worldwide. Literature search was performed on different sources to identify guidance documents for QA in mammography available worldwide in international bodies, healthcare providers, professional/scientific associations. The guidance documents identified were reviewed and a selection was compared for type of guidance (clinical/technical), technology and proposed QA methodologies focusing on dose and image quality (IQ) performance assessment. Fourteen protocols (targeted at conventional and digital mammography) were reviewed. All included recommendations for testing acquisition, processing and display systems associated with mammographic equipment. All guidance reviewed highlighted the importance of dose assessment and testing the Automatic Exposure Control (AEC) system. Recommended tests for assessment of IQ showed variations in the proposed methodologies. Recommended testing focused on assessment of low-contrast detection, spatial resolution and noise. QC of image display is recommended following the American Association of Physicists in Medicine guidelines. The existing QA guidance for mammography is derived from key documents (American College of Radiology and European Union guidelines) and proposes similar tests despite the variations in detail and methodologies. Studies reported on QA data should provide detail on experimental technique to allow robust data comparison. Countries aiming to implement a mammography/QA program may select/prioritise the tests depending on available technology and resources. •An effective QA program should be practical to implement in a clinical setting. •QA should address the various stages of the imaging chain: acquisition, processing and display. •AEC system QC testing is simple to implement and provides information on equipment performance.

  20. Adsorption of plasmid DNA on anion exchange chromatography media.

    PubMed

    Tarmann, Christina; Jungbauer, Alois

    2008-08-01

    Anion exchange chromatography (AEC) is a useful and effective tool for DNA purification, but due to average pore sizes between 40 and 100 nm most AEC resins lack truly useful binding capacities for plasmid DNA (pDNA). Equilibrium binding capacities and uptake kinetics of AEC media including conventional media (Source 30 Q, Q Sepharose HP), a polymer grafted medium (Fractogel EMD DEAE (M)), media with large pores (Celbeads DEAE, PL SAX 4000 A 30 microm) and a monolithic medium (CIM-DEAE) were investigated by batch uptake or shallow bed experiments at two salt concentrations. Theoretical and experimental binding capacities suggest that the shape of the pDNA molecule can be described by a rod with a length to diameter ratio of 20:1 and that the molecule binds in upright position. The arrangement of DNA like a brush at the surface can be considered as entropy driven, kind of self-assembly process which is inherent to highly and uniformly charged DNA molecules. The initial phase of adsorption is very fast and levels off, associated with a change in mass transfer mechanism. Feed concentrations higher than 0.1 mg/mL pDNA pronounce this effect. Monolithic media showed the fastest adsorption rate and highest binding capacity with 13 mg pDNA per mL.

  1. Final report of the decontamination and decommissioning of the exterior land areas at the Grand Junction Projects Office facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Widdop, M.R.

    1995-09-01

    The US Department of Energy (DOE) Grand Junction Projects Office (GJPO) facility occupies approximately 56.4 acres (22.8 hectares) along the Gunnison River near Grand Junction, Colorado. The site was contaminated with uranium ore and mill tailings during uranium-refining activities conducted by the Manhattan Engineer District and during pilot-milling experiments conducted for the US Atomic Energy Commission`s (AEC`s) domestic uranium procurement program. The GJPO facility was the collection and assay point for AEC uranium and vanadium oxide purchases until the early 1970s. The DOE Decontamination and Decommissioning Program sponsored the Grand Junction Projects Office Remedial Action Project (GJPORAP) to remediate themore » facility lands, site improvements, and the underlying aquifer. The site contractor, Rust Geotech, was the Remedial Action Contractor for GJPORAP. The exterior land areas of the facility assessed as contaminated have been remediated in accordance with identified standards and can be released for unrestricted use. Restoration of the aquifer will be accomplished through the natural flushing action of the aquifer during the next 50 to 80 years. The remediation of the DOE-GJPO facility buildings is ongoing and will be described in a separate report.« less

  2. Foxm1 transcription factor is required for lung fibrosis and epithelial-to-mesenchymal transition

    PubMed Central

    Balli, David; Ustiyan, Vladimir; Zhang, Yufang; Wang, I-Ching; Masino, Alex J; Ren, Xiaomeng; Whitsett, Jeffrey A; Kalinichenko, Vladimir V; Kalin, Tanya V

    2013-01-01

    Alveolar epithelial cells (AECs) participate in the pathogenesis of pulmonary fibrosis, producing pro-inflammatory mediators and undergoing epithelial-to-mesenchymal transition (EMT). Herein, we demonstrated the critical role of Forkhead Box M1 (Foxm1) transcription factor in radiation-induced pulmonary fibrosis. Foxm1 was induced in AECs following lung irradiation. Transgenic expression of an activated Foxm1 transcript in AECs enhanced radiation-induced pneumonitis and pulmonary fibrosis, and increased the expression of IL-1β, Ccl2, Cxcl5, Snail1, Zeb1, Zeb2 and Foxf1. Conditional deletion of Foxm1 from respiratory epithelial cells decreased radiation-induced pulmonary fibrosis and prevented the increase in EMT-associated gene expression. siRNA-mediated inhibition of Foxm1 prevented TGF-β-induced EMT in vitro. Foxm1 bound to and increased promoter activity of the Snail1 gene, a critical transcriptional regulator of EMT. Expression of Snail1 restored TGF-β-induced loss of E-cadherin in Foxm1-deficient cells in vitro. Lineage-tracing studies demonstrated that Foxm1 increased EMT during radiation-induced pulmonary fibrosis in vivo. Foxm1 is required for radiation-induced pulmonary fibrosis by enhancing the expression of genes critical for lung inflammation and EMT. PMID:23288041

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goodson, J.O.

    This is the first of three volumes which document the historical development of the first US compressed-air energy storage (CAES) Power-generation facility. Volume 1 is a background report and presents a chronicle of the development of the CAES facility from the early interest in CAES until inception of engineering/construction on August 11, 1988. The 110 MW - 26 hr CAES plant is owned and operated by Alabama Electric Cooperative, Inc. (AEC) of Andalusia, Alabama. The plant is the first CAES plant in the United States and the world's first CAES facility incorporating a recuperator to improve efficiency. The plant suppliesmore » competitively priced peaking power to the AEC owner members. The economics of CAES-produced power is attractive because the energy-intensive air-compression mode is powered by relatively inexpensive base-load power external to the CAES plant. The compressed-air energy is stored underground until needed, and during the power-production mode, the only fuel required is that to heat the compressed air to expander-inlet temperature. The project development for AEC's CAES plant involved much planning and preliminary design work. Specifically, this included load and generation-planning studies, power-supply selections, conceptual designs, project administration, air-storage cavern and turbomachinery specifications and design, contract requirements, environmental and licensing issues, and construction planning.« less

  4. FRACTIONATING COLUMN PRODUCT COLLECTOR CONTROL

    DOEpatents

    Paxson, G.D. Jr.

    1964-03-10

    Means for detecting minute fluid products from a chemical separation column and for advancing a collector tube rack in order to automatically separate and collect successive fractionated products are described. A charge is imposed on the forming drops at the column orifice to create an electric field as the drop falls in the vicinity of a sensing plate. The field is detected by an electrometer tube coupled to the plate causing an output signal to actuate rotation of a collector turntable rack, thereby positioning new collectors under the orifice. The invention provides reliable automatic collection independent of drop size, rate of fall, or chemical composition. (AEC)

  5. AMPLITUDE DISCRIMINATOR HAVING SEPARATE TRIGGERING AND RECOVERY CONTROLS UTILIZING AUTOMATIC TRIGGERING

    DOEpatents

    Chase, R.L.

    1962-01-23

    A transistorized amplitude discriminator circuit is described in which the initial triggering sensitivity and the recovery threshold are separately adjustable in a convenient manner. The discriminator is provided with two independent bias components, one of which is for circuit hysteresis (recovery) and one of which is for trigger threshold level. A switching circuit is provided to remove the second bias component upon activation of the trigger so that the recovery threshold is always at the point where the trailing edge of the input signal pulse goes through zero or other desired value. (AEC)

  6. Neutrophil autophagy and extracellular DNA traps contribute to airway inflammation in severe asthma.

    PubMed

    Pham, D L; Ban, G-Y; Kim, S-H; Shin, Y S; Ye, Y-M; Chwae, Y-J; Park, H-S

    2017-01-01

    Autophagy and neutrophil extracellular DNA traps (NETs) are implicated in asthma; however, their roles in asthma pathogenesis have not been elucidated. We compared autophagy and NET production levels from peripheral blood neutrophils (PBNs) of patients with severe asthma (SA) and non-severe asthma (NSA). Additionally, we investigated the inflammatory effects of NETs on human airway epithelial cells (AECs) and peripheral blood eosinophils (PBEs). Peripheral blood neutrophils from patients with SA (n = 30) and NSA (n = 38) were treated with interleukin (IL)-8 (100 ng/mL). Autophagy (light chain 3-II expression) and NET production levels were evaluated by Western blot, immunofluorescence microscopy, and PicoGreen assay. The effects of NETs on AECs were assessed by investigating cell death, cell detachment, expression of occludin and claudin-1, and IL-8 production; the effects of NETs on PBEs were examined by investigating the activation and release of eosinophil cationic protein (ECP) and eosinophil-derived neurotoxin (EDN). Untreated and IL-8-treated PBNs from the SA group produced higher autophagy and NET levels compared with those from the NSA group (P < 0.01). IL-8 increased autophagy and NET levels in PBNs from the SA group, but not from the NSA group. NET levels were correlated with autophagy levels in PBNs (P < 0.001). IL-8-induced NET production levels negatively were correlated with FEV1/FVC (r = -0.700, P = 0.016). NETs induced cell death, detachment, degradation of occludin and claudin-1, and IL-8 production from AECs. Higher levels of NET-induced ECP and EDN were released from PBEs in SA compared with NSA groups. Neutrophil autophagy and NETs could enhance asthma severity by damaging airway epithelium and triggering inflammatory responses of AECs and PBEs. Modulating neutrophil autophagy and NET production may be a new target therapy for SA. © 2016 John Wiley & Sons Ltd.

  7. An improvement to the ligand optimisation method (LOM) for measuring the apparent dissociation constant and ligand purity in Ca2+ and Mg2+ buffer solutions.

    PubMed

    McGuigan, John A S; Kay, James W; Elder, Hugh Y

    2014-01-01

    In Ca(2+)/Mg(2+) buffers the calculated ionised concentrations ([X(2+)]) can vary by up to a factor of seven. Since there are no defined standards it is impossible to check calculated [X(2+)], making measurement essential. The ligand optimisation method (LOM) is an accurate method to measure [X(2+)] in Ca(2+)/Mg(2+) buffers; independent estimation of ligand purity extends the method to pK(/) < 4. To simplify calculation, Excel programs ALE and AEC were compiled for LOM and its extension. This paper demonstrates that the slope of the electrode in the pX range 2.000-3.301 deviates from Nernstian behaviour as it depends on the value of the lumped interference, Σ. ALE was modified to include this effect; this modified program SALE, and the programs ALE and AEC were used on simulated data for Ca(2+)-EGTA and Mg(2+)-ATP buffers, to calculate electrode and buffer characteristics as a function of Σ. Ca(2+)-electrodes have a Σ < 10(-6) mol/l and there was no difference amongst the three methods. The Σ for Mg(2+)-electrodes lies between 10(-5) and 1.5 (∗) 10(-5) mol/l and calculated [Mg(2+)] with ALE were around 3% less than the true value. SALE and AEC correctly predicted [Mg(2+)]. SALE was used to recalculate K(/) and pK(/) on measured data for Ca(2+)-EGTA and Mg(2+)-EDTA buffers. These results demonstrated that it is pK(/) that is normally distributed. Until defined standards are available, [X(2+)] in Ca(2+)/Mg(2+) buffers have to be measured. The most appropriate method is to use Ca(2+)/Mg(2) electrodes combined with the Excel programs SALE or AEC. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Development of asthmatic inflammation in mice following early-life exposure to ambient environmental particulates and chronic allergen challenge

    PubMed Central

    Herbert, Cristan; Siegle, Jessica S.; Shadie, Alexander M.; Nikolaysen, Stina; Garthwaite, Linda; Hansbro, Nicole G.; Foster, Paul S.; Kumar, Rakesh K.

    2013-01-01

    SUMMARY Childhood exposure to environmental particulates increases the risk of development of asthma. The underlying mechanisms might include oxidant injury to airway epithelial cells (AEC). We investigated the ability of ambient environmental particulates to contribute to sensitization via the airways, and thus to the pathogenesis of childhood asthma. To do so, we devised a novel model in which weanling BALB/c mice were exposed to both ambient particulate pollutants and ovalbumin for sensitization via the respiratory tract, followed by chronic inhalational challenge with a low mass concentration of the antigen. We also examined whether these particulates caused oxidant injury and activation of AEC in vitro. Furthermore, we assessed the potential benefit of minimizing oxidative stress to AEC through the period of sensitization and challenge by dietary intervention. We found that characteristic features of asthmatic inflammation developed only in animals that received particulates at the same time as respiratory sensitization, and were then chronically challenged with allergen. However, these animals did not develop airway hyper-responsiveness. Ambient particulates induced epithelial injury in vitro, with evidence of oxidative stress and production of both pro-inflammatory cytokines and Th2-promoting cytokines such as IL-33. Treatment of AEC with an antioxidant in vitro inhibited the pro-inflammatory cytokine response to these particulates. Ambient particulates also induced pro-inflammatory cytokine expression following administration to weanling mice. However, early-life dietary supplementation with antioxidants did not prevent the development of an asthmatic inflammatory response in animals that were exposed to particulates, sensitized and challenged. We conclude that injury to airway epithelium by ambient environmental particulates in early life is capable of promoting the development of an asthmatic inflammatory response in sensitized and antigen-challenged mice. These findings are likely to be relevant to the induction of childhood asthma. PMID:23223614

  9. STABILIZED RARE EARTH OXIDES FOR A CONTROL ROD AND METHOD OF PREPARATION

    DOEpatents

    McNees, R.A.; Potter, R.A.

    1964-01-14

    A method is given for preparing mixed oxides of the formula MR/sub x/O/ sub 12/ wherein M is tungsten or molybdenum and R is a rare earth in the group consisting of samarium, europium, dysprosium, and gadolinium and x is 4 to 5. Oxides of this formula, and particularly the europiumcontaining species, are useful as control rod material for water-cooled nuclear reactors owing to their stability, favorable nuclear properties, and resistance to hydration. These oxides may be utilized as a dispersion in a stainlesssteel matrix. Preparation of these oxides is effected by blending tungsten oxide or molybdenum oxide with a rare earth oxide, compressing the mixture, and firing at an elevated temperature in an oxygen-containing atmosphere. (AEC)

  10. METHOD FOR SENSING DEGREE OF FLUIDIZATION IN FLUIDIZED BED

    DOEpatents

    Levey, R.P. Jr.; Fowler, A.H.

    1961-12-12

    A method is given for detecting, indicating, and controlling the degree of fluidization in a fluid-bed reactor into which powdered material is fed. The method comprises admitting of gas into the reactor, inserting a springsupported rod into the powder bed of the reactor, exciting the rod to vibrate at its resonant frequency, deriving a signal responsive to the amplitude of vibi-ation of the rod and spring, the signal being directiy proportional to the rate of flow of the gas through the reactor, displaying the signal to provide an indication of the degree of fluidization within the reactor, and controlling the rate of gas flow into the reactor until said signal stabilizes at a constant value to provide substantially complete fluidization within the reactor. (AEC)

  11. Feasibility of space disposal of radioactive nuclear waste. 2: Technical summary

    NASA Technical Reports Server (NTRS)

    1974-01-01

    The feasibility of transporting radioactive waste produced in the process of generating electricity in nuclear powerplants into space for ultimate disposal was investigated at the request of the AEC as a NASA in-house effort. The investigation is part of a broad AEC study of methods for long-term storage or disposal of radioactive waste. The results of the study indicate that transporting specific radioactive wastes, particularly the actinides with very long half-lives, into space using the space shuttle/tug as the launch system, appears feasible from the engineering and safety viewpoints. The space transportation costs for ejecting the actinides out of the solar system would represent less than a 5-percent increase in the average consumer's electric bill.

  12. Activation of protein kinase B (PKB/Akt) and risk of lung cancer among rural women in India who cook with biomass fuel.

    PubMed

    Roychoudhury, Sanghita; Mondal, Nandan Kumar; Mukherjee, Sayali; Dutta, Anindita; Siddique, Shabana; Ray, Manas Ranjan

    2012-02-15

    The impact of indoor air pollution (IAP) from biomass fuel burning on the risk of carcinogenesis in the airways has been investigated in 187 pre-menopausal women (median age 34years) from eastern India who cooked exclusively with biomass and 155 age-matched control women from same locality who cooked with cleaner fuel liquefied petroleum gas. Compared with control, Papanicolau-stained sputum samples showed 3-times higher prevalence of metaplasia and 7-times higher prevalence of dysplasia in airway epithelial cell (AEC) of biomass users. Immunocytochemistry showed up-regulation of phosphorylated Akt (p-Akt(ser473) and p-Akt(thr308)) proteins in AEC of biomass users, especially in metaplastic and dysplastic cells. Compared with LPG users, biomass-using women showed marked rise in reactive oxygen species (ROS) generation and depletion of antioxidant enzyme, superoxide dismutase (SOD) indicating oxidative stress. There were 2-5 times more particulate pollutants (PM(10) and PM(2.5)), 72% more nitrogen dioxide and 4-times more particulate-laden benzo(a)pyrene, but no change in sulfur dioxide in indoor air of biomass-using households, and high performance liquid chromatography estimated 6-fold rise in the concentration of benzene metabolite trans,trans-muconic acid (t,t-MA) in urine of biomass users. Metaplasia and dysplasia, p-Akt expression and ROS generation were positively associated with PM and t,t-MA levels. It appears that cumulative exposure to biomass smoke increases the risk of lung carcinogenesis via oxidative stress-mediated activation of Akt signal transduction pathway. Copyright © 2011 Elsevier Inc. All rights reserved.

  13. Different trends in extreme and median surface aerosol extinction coefficients over China inferred from quality-controlled visibility data

    NASA Astrophysics Data System (ADS)

    Li, Jing; Li, Chengcai; Zhao, Chunsheng

    2018-03-01

    Although the temporal changes in aerosol properties have been widely investigated, the majority of studies has focused on average conditions without much emphasis on the extremes. However, the latter can be more important in terms of human health and climate change. This study uses a previously validated, quality-controlled visibility dataset to investigate the long-term trends (expressed in terms of relative changes) in extreme surface aerosol extinction coefficient (AEC) over China and compares them with the median trends. Two methods are used to independently evaluate the trends, which arrive at consistent results. The signs of extreme and median trends are generally coherent, whereas their magnitudes show distinct spatial and temporal differences. In the 1980s, an overall positive trend is found throughout China with the extreme trend exceeding the mean trend, except for northwest China and the North China Plain. In the 1990s, AEC over northeast and northwest China started to decline while the rest of the country still exhibited an increase. The extreme trends continued to dominate in the south while they yielded to the mean trend in the north. After the year 2000, the extreme trend became weaker than the mean trend overall in terms of both the magnitude and significance level. The annual trend can be primarily attributed to winter and fall trends. The results suggest that the decadal changes in pollution in China may be governed by different mechanisms. Synoptic conditions that often result in extreme air quality changes might have dominated in the 1980s, whereas emission increase might have been the main factor for the 2000s.

  14. [The benefits of digital air leak assessment after pulmonary resection: prospective and comparative study].

    PubMed

    Mier, José M; Molins, Laureano; Fibla, Juan J

    2010-06-01

    Persistent air leaks represent the most common pulmonary complication after elective lung resection. Since there are insufficient data in the literature regarding variability in the withdrawal of postoperative pleural drainages, we have designed a prospective, consecutive and comparative study to evaluate if the use of digital devices (Thopaz and DigiVent) to measure postoperative air leak compared to a Pleur-Evac varies on deciding when to withdraw chest tubes after lung resection. A prospective, consecutive and comparative trial was conducted in 75 patients who underwent elective pulmonary resection for non small cell lung cancer. This study compared two digitals devices with the current analogue version in 75 patients. The digital and analogue groups had 26, 24, and 25 patients, respectively. Clinical population data were not statistically different between the groups. The withdrawal of the chest tube was Thopaz, 2.4 days; Digivent, 3.3 days and PleurEvac, 4.5 days. Patients and nurses were subjectively more comfortable with digital devices. Surgeons obtained more objective information with digital devices. The safety mechanism of the Thopaz was also subjectively better, and one patient was discharged home without complications after one week. The digital and continuous measurement of air leak instead of the currently used static analogue systems reduced the chest tube withdrawal and hospital stay by more accurately and reproducibly measuring air leak. Intrapleural pressure curves from the Digivent may also help predict the optimal chest tube setting for each patient. The Thopaz alarm mechanism is very useful to prevent deficiencies in the mechanism and do not required wall suction. Copyright (c) 2010 AEC. Published by Elsevier Espana. All rights reserved.

  15. Reliability of solid-state lighting electrical drivers subjected to WHTOL accelerated aging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lall, Pradeep; Sakalauku, Peter; Davis, Lynn

    An investigation of a solid-state lighting (SSL) luminaire with the focus on the electronic driver which has been exposed to a standard wet hot temperature operating life (WHTOL) of 85% RH and 85°C in order to assess reliability of prolonged exposer to a harsh environment has been conducted. SSL luminaires are beginning introduced as head lamps in some of today's luxury automobiles and may also be fulfilling a variety of important outdoor applications such as overhead street lamps, traffic signals and landscape lighting. SSL luminaires in these environments are almost certain to encounter excessive moisture from humidity and high temperaturesmore » for a persistent period of time. The lack of accelerated test methods for LEDs to assess long-term reliability prior to introduction into the marketplace, a need for SSL physics based PHM modeling indicators for assessment and prediction of LED life, as well as the U.S. Department of Energy's R&D roadmap to replace todays lighting with SSL luminaires makes it important to increase the understanding of the reliability of SSL devices, specifically, in harsh environment applications. In this work, a set of SSL electrical drivers were investigated to determine failure mechanisms that occur during prolonged harsh environment applications. Each driver consists of four aluminum electrolytic capacitors (AECs) of three different types and was considered the weakest component inside the SSL electrical driver. The reliability of the electrical driver was assessed by monitoring the change in capacitance and the change in equivalent series resistance for each AEC, as well as monitoring the luminous flux of the SSL luminaire or the output of the electrical driver. The luminous flux of a pristine SSL electrical driver was also monitored in order to detect minute changes in the electrical drivers output and to aid in the investigation of the SSL luminaires reliability. The failure mechanisms of the electrical drivers have been determined and are presented in this paper.« less

  16. Insulin Treatment Cannot Promote Lipogenesis in Rat Fetal Lung in Gestational Diabetes Mellitus Because of Failure to Redress the Imbalance Among SREBP-1, SCAP, and INSIG-1.

    PubMed

    Li, Jinyan; Qian, Guanhua; Zhong, Xiaocui; Yu, Tinghe

    2018-03-01

    Gestational diabetes mellitus (GDM) has a higher incidence of neonatal respiratory distress syndrome, and lipogenesis is required for the synthesis of pulmonary surfactants. The aim of this study was to determine the effect of insulin treatment in GDM on the production of lipids in the lungs of fetal rats. GDM was induced by streptozotocin, and insulin was used to manage diabetes. Type II alveolar epithelial cells (AEC II), bronchoalveolar lavage fluid (BALF), and lung tissues of the neonatal rats were sampled for analyses. Insulin treatment could not decrease plasma glucose to normal level at a later gestational stage. Lipids/phospholipids in AEC II, BALF, and lung tissues decreased in GDM, and insulin treatment could not increase the levels; quantitative PCR and western blotting demonstrated a lower level of sterol regulator element-binding protein 1 (SREBP-1), SREBP cleavage-activating protein (SCAP), and insulin-induced gene 1 (INSIG-1) in GDM, but insulin treatment upregulated only SREBP-1. Nuclear translocation of the SREBP-1 protein in AEC II was impaired in GDM, which could not be ameliorated by insulin treatment. These findings indicated that insulin treatment in GDM cannot promote lipogenesis in the fetal lung because of failure to redress the imbalance among SREBP-1, SCAP, and INSIG-1.

  17. Integrated Transcriptomic and Epigenomic Analysis of Primary Human Lung Epithelial Cell Differentiation

    PubMed Central

    Marconett, Crystal N.; Zhou, Beiyun; Rieger, Megan E.; Selamat, Suhaida A.; Dubourd, Mickael; Fang, Xiaohui; Lynch, Sean K.; Stueve, Theresa Ryan; Siegmund, Kimberly D.; Berman, Benjamin P.

    2013-01-01

    Elucidation of the epigenetic basis for cell-type specific gene regulation is key to gaining a full understanding of how the distinct phenotypes of differentiated cells are achieved and maintained. Here we examined how epigenetic changes are integrated with transcriptional activation to determine cell phenotype during differentiation. We performed epigenomic profiling in conjunction with transcriptomic profiling using in vitro differentiation of human primary alveolar epithelial cells (AEC). This model recapitulates an in vivo process in which AEC transition from one differentiated cell type to another during regeneration following lung injury. Interrogation of histone marks over time revealed enrichment of specific transcription factor binding motifs within regions of changing chromatin structure. Cross-referencing of these motifs with pathways showing transcriptional changes revealed known regulatory pathways of distal alveolar differentiation, such as the WNT and transforming growth factor beta (TGFB) pathways, and putative novel regulators of adult AEC differentiation including hepatocyte nuclear factor 4 alpha (HNF4A), and the retinoid X receptor (RXR) signaling pathways. Inhibition of the RXR pathway confirmed its functional relevance for alveolar differentiation. Our incorporation of epigenetic data allowed specific identification of transcription factors that are potential direct upstream regulators of the differentiation process, demonstrating the power of this approach. Integration of epigenomic data with transcriptomic profiling has broad application for the identification of regulatory pathways in other models of differentiation. PMID:23818859

  18. Building Information Modelling: Challenges and Barriers in Implement of BIM for Interior Design Industry in Malaysia

    NASA Astrophysics Data System (ADS)

    Hamid, A. B. Abd; Taib, M. Z. Mohd; Razak, A. H. N. Abdul; Embi, M. R.

    2018-04-01

    Building Information Modelling (BIM) is an innovative approach that has developed crossways the global in architecture, engineering and construction (AEC) industry. The construction industry of Malaysia has undergone a rapid development and dynamic technology adoption in advance and methods between the players industry and stakeholders. Consequently, limited technologies and devices have not been successful as it should have been. This study will be emphasizing scenarios of challenges and barriers in adopting BIM in interior design industry in Malaysia. The study was emphasizing the challenges and barriers in BIM usage from the designer’s perspective. The data are collected through the questionnaires as to identifying the barriers, knowledge, readiness and awareness and distributed to interior design firms were selected randomly. The finding of this research is to examine the barriers and causes of variables BIM usage for interior design industry in Malaysia. The outcome of this study is to identify the constraint of adoption BIM in interior design industry compare to others players in same industry.

  19. REMOTE CONTROL MANIPULATOR

    DOEpatents

    Coffman, R.T.

    1962-11-27

    The patent covers a remote-control manipulator in which a tool is carried on a tube at an end thereof angularly related to the main portion of the tube and joined thereto by a curved section. The main portion of the tube is mounted for rotation and axial shifting in a wall separating safe and dangerous areas. The tool is actuated to grasp and release an object in the dangerous area by means of a compound shaft extending through the tube, the shaft having a flexible section extending through the curved section of the tube. The tool is moved about in the dangerous area by rotation and axial movement of the main portion of the tube. Additional movement of the tool is obtained through axial shifting of the shaft with respect to the tube through which it extends. (AEC)

  20. REMOVAL OF RADIOACTIVE IONS FROM WATERS

    DOEpatents

    Silker, W.B.

    1962-04-10

    A process for removing neutron-reaction products, such as phosphorus, arsenic, manganese, copper, zinc, lanthanides, and actinides, from aqueous solutions by sorption on particles of aluminum metal is described. (AEC)

  1. RECONDITIONING FUEL ELEMENTS

    DOEpatents

    Brandt, H.L.

    1962-02-20

    A process is given for decanning fuel elements that consist of a uranium core, an intermediate section either of bronze, silicon, Al-Si, and uranium silicide layers or of lead, Al-Si, and uranium silicide layers around said core, and an aluminum can bonded to said intermediate section. The aluminum can is dissolved in a solution of sodium hydroxide (9 to 20 wt%) and sodium nitrate (35 to 12 wt %), and the layers of the intermediate section are dissolved in a boiling sodium hydroxide solution of a minimum concentration of 50 wt%. (AEC) A method of selectively reducing plutonium oxides and the rare earth oxides but not uranium oxides is described which comprises placing the oxides in a molten solvent of zinc or cadmium and then adding metallic uranium as a reducing agent. (AEC)

  2. Advertising the atom: federal promotion of nuclear power, 1953-1984

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, M.

    The public relations strategies of the Atomic Energy Commission (AEC) and the nuclear power industry reveal both public and official perceptions of nuclear power and the social uses of technology in general during the first 15 years after passage of the Atomic Energy Act of 1954. The relation between nuclear promotion and regulation also helps explain the environmental crisis of the 1969-1984 years. Project Plowshare coincides roughly with the early promotional years, and provides a case study of the relation of regulatory standards to promotion in AEC policymaking. The author examines the environmentalists challenge to nuclear power that emerged inmore » 1969 alongside government and industry response. He concludes with an assessment of the present state of federal nuclear power policy and of the nuclear power industry.« less

  3. SABERS. Stand-Alone ADIC Binary Exploitation Resources System. Volume II.

    DTIC Science & Technology

    1981-09-01

    XXXQ S X3W3 w P-’ 00S00 z~ ML Z.14.J SM C . >C.> 3c Q . . . a.E.C HL 0 c Ccc4 z _,> 0o~. 0 0) "XI 8-4 zw0 Ŕ >e 0 - 0 SMK " CELh uw C WnI-EW e cm (A...Recognizer ----- TOINT ASCII to Integer Converter * - ACESS Access Control Word Recognizer "* -.. STRAIN Input Constraint Processor S----GETBND Input...exclude the screen cursor from these areas. The code for the routine is found in the file ACESS.FLX. STRAIN STRAIN recognizes the various forms of user

  4. ION SOURCE WITH SPACE CHARGE NEUTRALIZATION

    DOEpatents

    Flowers, J.W.; Luce, J.S.; Stirling, W.L.

    1963-01-22

    This patent relates to a space charge neutralized ion source in which a refluxing gas-fed arc discharge is provided between a cathode and a gas-fed anode to provide ions. An electron gun directs a controlled, monoenergetic electron beam through the discharge. A space charge neutralization is effected in the ion source and accelerating gap by oscillating low energy electrons, and a space charge neutralization of the source exit beam is effected by the monoenergetic electron beam beyond the source exit end. The neutralized beam may be accelerated to any desired energy at densities well above the limitation imposed by Langmuir-Child' s law. (AEC)

  5. PARTICLE SEPARATION METHOD

    DOEpatents

    Anderson, N.G.

    1963-01-29

    An improved method of sedimentation is described. A series of spaced surfaces of powdered material positioned normal to the centrifugal field concentrates the larger, slower moving molecules of a liquid and hastens sedimentation. (AEC)

  6. NUCLEAR REACTOR

    DOEpatents

    Sherman, J.; Sharbaugh, J.E.; Fauth, W.L. Jr.; Palladino, N.J.; DeHuff, P.G.

    1962-10-23

    A nuclear reactor incorporating seed and blanket assemblies is designed. Means are provided for obtaining samples of the coolant from the blanket assemblies and for varying the flow of coolant through the blanket assemblies. (AEC)

  7. METHOD OF BRAZING

    DOEpatents

    Patriarca, P.; Slaughter, G.M.

    1962-11-27

    A method of joining metal surfaces is given. Surfaces having nickel or iron as the base metal are joined together with a brazing composition consisting of 80% nickel, 10% phosphorus, and 10% chromium. (AEC)

  8. FLUORINATION OF OXIDIC NUCLEAR FUEL

    DOEpatents

    Mecham, W.J.; Gabor, J.D.

    1963-07-23

    A process of volatilizing fissionable material away from fission products, present together in neutron-bombarded uranium oxide, by reaction with an oxygen-fluorine mixture at 350 to 500 deg C is described. (AEC)

  9. MEASURING CIRCUIT

    DOEpatents

    Mahoney, J.R.

    1963-01-29

    A measuring and balancing arrangement for mass spectrometers permits the ready determination of isotopic ratios and mole and weight percentages by employing a selection of amplifier input resistors to vary sensitivity in a bridge arrangement. (AEC)

  10. Gene p63: In ectrodactyly-ectodermal dysplasia clefting, ankyloblepharon-ectodermal dysplasia, Rapp-Hodgkin syndrome.

    PubMed

    van Straten, Cornelia; Butow, Kurt-W

    2013-01-01

    An analysis was made of three different syndromes associated with p63 gene mutations, known as ectrodactyly-ectodermal dysplasia-clefting syndrome (EEC), ankyloblepharon-ectodermal dysplasia clefting syndrome (AEC or Hay-Wells) and Rapp-Hodgkin syndrome (RHS). The postoperative complications associated with their cleft reconstructions were also evaluated. Extensive demographic information, in particular of the clinical appearances, associated malformations, and the types and complications of the reconstructive surgical procedures, were recorded of these syndromic cases occurring in a database of 3621 facial cleft deformity patients. The data was analyzed using the Microsoft Excel program. A total of 10 (0.28%) cases of p63 associated syndromes were recorded: EEC (6), RHS (3), and AEC (1). The following clinical cleft appearances were noted - EEC = 6: CLA 1 -right side unilateral (female); CLAP 4 - right side (1) + left side (1) unilateral (male + female); bilateral (2) (males); hPsP 1 (female) (divided in 3 Black, 2 White, 1 Indian); RHS = 3: CLAP 2 (White males); hPsP 1 (White female); AEC = 1: CLAP bilateral (White male). Other features of the syndromes were: skin, hand, foot, tooth, hair and nail involvement, and light sensitivity. Postoperative complications included: (i) stenosis of nasal opening, especially after reconstruction of the bilateral cleft lip and the columella lengthening (2 cases), (ii) premaxilla-prolabium fusion (2 cases), (iii) repeated occurrence of oro-nasal fistula in the hard palate (4 cases), and (iv) dysgnathial development of midfacial structures (3 cases). Three different p63 associated syndromes (EEC, AEC, and RHS) were diagnosed (0.27% of the total facial cleft deformities database). The majority of the cases presented with a bilateral CLAP in males only. A number of females and males had unilateral CLA. The hPsP-cleft was recorded in females only. The associated ectodermal component most probably had a profoundly negative influence on postoperatively wound healing, which was observed in particular at the nasal openings, the premaxilla sulcus and in the hard palate mucosa. The reconstruction of p63 associated syndromes is a greater challenge than the usual cleft reconstruction to the surgeon.

  11. Role of p53–fibrinolytic system cross-talk in the regulation of quartz-induced lung injury

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhandary, Yashodhar P.; Shetty, Shwetha K.; Marudamuthu, Amarnath S.

    2015-03-01

    Silica is the major component of airborne dust generated by wind, manufacturing and/or demolition. Chronic occupational inhalation of silica dust containing crystalline quartz is by far the predominant form of silicosis in humans. Silicosis is a progressive lung disease that typically arises after a very long latency and is a major occupational concern with no known effective treatment. The mechanism of silicosis is not clearly understood. However, silicosis is associated with increased cell death, expression of redox enzymes and pro-fibrotic cytokines and chemokines. Since alveolar epithelial cell (AEC) death and disruption of alveolar fibrinolysis is often associated with both acutemore » and chronic lung injuries, we explored whether p53-mediated changes in the urokinase-type plasminogen activator (uPA) system contributes to silica-induced lung injury. We further sought to determine whether caveolin-1 scaffolding domain peptide (CSP), which inhibits p53 expression, mitigates lung injury associated with exposure to silica. Lung tissues and AECs isolated from wild-type (WT) mice exposed to silica exhibit increased apoptosis, p53 and PAI-1, and suppression of uPA expression. Treatment of WT mice with CSP inhibits PAI-1, restores uPA expression and prevents AEC apoptosis by suppressing p53, which is otherwise induced in mice exposed to silica. The process involves CSP-mediated inhibition of serine-15 phosphorylation of p53 by inhibition of protein phosphatase 2A-C (PP2A-C) interaction with silica-induced caveolin-1 in AECs. These observations suggest that changes in the p53–uPA fibrinolytic system cross-talk contribute to lung injury caused by inhalation of silica dust containing crystalline quartz and is protected by CSP by targeting this pathway. - Highlights: • Chronic exposure to quartz dusts is a major cause of lung injury and silicosis. • The survival of patients with silicosis is bleak due to lack of effective treatments. • This study defines a new role of p53–uPA cross-talk in quartz-induced lung injury. • Targeting the p53–uPA system inhibits ATII cell/lung injury due to quartz exposure.« less

  12. Dietary α-ketoglutarate supplementation improves hepatic and intestinal energy status and anti-oxidative capacity of Cherry Valley ducks.

    PubMed

    Guo, Shuangshuang; Duan, Rui; Wang, Lei; Hou, Yongqing; Tan, Linglin; Cheng, Qiang; Liao, Man; Ding, Binying

    2017-11-01

    α-Ketoglutarate (AKG) is an extensively used dietary supplement in human and animal nutrition. The aim of the present study was to investigate effects of dietary AKG supplementation on the energy status and anti-oxidative capacity in liver and intestinal mucosa of Cherry Valley ducks. A total of 80 1-day-old ducks were randomly assigned into four groups, in which ducks were fed basal diets supplemented with 0% (control), 0.5%, 1.0% and 1.5% AKG, respectively. Graded doses of AKG supplementation linearly decreased the ratio of adenosine monophosphate (AMP) to adenosine triphosphate (ATP) in the liver, but increased ATP content and adenylate energy charge (AEC) in a quadratic and linear manner, respectively (P < 0.05). Increasing dietary AKG supplemental levels produced linear positive responses in ATP content and AEC, and negative responses in AMP concentration, the ratio of AMP to ATP and total adenine nucleotide in the ileal mucosa (P < 0.05). All levels of dietary AKG reduced the production of jejunal hydrogen peroxide and hepatic malondialdehyde (P < 0.05). Hepatic and ileal messenger RNA expression of AMP kinase α-1 and hypoxia-inducible factor-1α were linearly up-regulated as dietary AKG supplemental levels increased (P < 0.05). In conclusion, dietary AKG supplementation linearly or quadratically enhanced hepatic and intestinal energy storage and anti-oxidative capacity of Cherry Valley ducks. © 2017 Japanese Society of Animal Science.

  13. Comparison of effects of dose on image quality in digital breast tomosynthesis across multiple vendors

    NASA Astrophysics Data System (ADS)

    Zhao, Amy; Santana, Maira; Samei, Ehsan; Lo, Joseph

    2017-03-01

    In traditional radiography and computed tomography (CT), contrast is an important measure of image quality that, in theory, does not vary with dose. While increasing dose may increase the overall contrast-to-noise ratio (CNR), the contrast in an image should be primarily dependent on variation in tissue density and attenuation. We investigated the behavior of all three currently FDA-approved vendors' 3D DBT systems (Siemens, Hologic, and General Electric (GE)) using the Computerized Imaging Reference Systems (CIRS) Model 011A Breast Phantom and found that for both Siemens and Hologic systems, contrast increased with dose across multiple repeated trials. For these two systems, experimental CNR also appeared to increase above the expected CNR, which suggests that these systems seem to have introduced post-processing by manipulation of contrast, and thus DBT data cannot be used to reliably quantify tissue characteristics. Additional experimentation with both 2D mammography and 3D DBT systems from GE in addition to the previously mentioned vendors, however, suggested that this relationship is not true for all systems. An initial comparison of contrast vs. dose showed no relationship between contrast and dose for 2D mammography, with the contrast remaining relatively constant in the dose range of 33% of the automatic exposure control setting (AEC) to 300% AEC for all three vendors. The GE DBT system also did not exhibit increased contrast with increased dose, suggesting that the behavior of 3D DBT systems is vendor-specific.

  14. STEAM GENERATOR FOR NUCLEAR REACTOR

    DOEpatents

    Kinyon, B.W.; Whitman, G.D.

    1963-07-16

    The steam generator described for use in reactor powergenerating systems employs a series of concentric tubes providing annular passage of steam and water and includes a unique arrangement for separating the steam from the water. (AEC)

  15. 27 CFR 9.69 - Yakima Valley.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Bennett Ranch; (2) Then due east approximately 0.2 mile to the boundary of the Hanford Atomic Energy Commission Works; (3) Then southeast following the boundary of the Hanford AEC Works along the Rattlesnake...

  16. 27 CFR 9.69 - Yakima Valley.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Bennett Ranch; (2) Then due east approximately 0.2 mile to the boundary of the Hanford Atomic Energy Commission Works; (3) Then southeast following the boundary of the Hanford AEC Works along the Rattlesnake...

  17. 27 CFR 9.69 - Yakima Valley.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Bennett Ranch; (2) Then due east approximately 0.2 mile to the boundary of the Hanford Atomic Energy Commission Works; (3) Then southeast following the boundary of the Hanford AEC Works along the Rattlesnake...

  18. PRECIPITATION OF ZIRCONIUM AND FLUORIDE IONS FROM SOLUTIONS

    DOEpatents

    Newby, B.J.

    1963-06-11

    A process is given for removing zirconium and fluorine ions from aqueous solutions also containing uranium(VI). The precipitation is carried out with sodium formate, and the uranium remains in solution. (AEC)

  19. COUPLING

    DOEpatents

    Frisch, E.; Johnson, C.G.

    1962-05-15

    A detachable coupling arrangement is described which provides for varying the length of the handle of a tool used in relatively narrow channels. The arrangement consists of mating the key and keyhole formations in the cooperating handle sections. (AEC)

  20. Alternative Sources of Adult Stem Cells: Human Amniotic Membrane

    NASA Astrophysics Data System (ADS)

    Wolbank, Susanne; van Griensven, Martijn; Grillari-Voglauer, Regina; Peterbauer-Scherb, Anja

    Human amniotic membrane is a highly promising cell source for tissue engineering. The cells thereof, human amniotic epithelial cells (hAEC) and human amniotic mesenchymal stromal cells (hAMSC), may be immunoprivileged, they represent an early developmental status, and their application is ethically uncontroversial. Cell banking strategies may use freshly isolated cells or involve in vitro expansion to increase cell numbers. Therefore, we have thoroughly characterized the effect of in vitro cultivation on both phenotype and differentiation potential of hAEC. Moreover, we present different strategies to improve expansion including replacement of animal-derived supplements by human platelet products or the introduction of the catalytic subunit of human telomerase to extend the in vitro lifespan of amniotic cells. Characterization of the resulting cultures includes phenotype, growth characteristics, and differentiation potential, as well as immunogenic and immunomodulatory properties.

  1. Collagen reconstitution is inversely correlated with induction of limb regeneration in Ambystoma mexicanum.

    PubMed

    Satoh, Akira; Hirata, Ayako; Makanae, Aki

    2012-03-01

    Amphibians can regenerate missing body parts, including limbs. The regulation of collagen has been considered to be important in limb regeneration. Collagen deposition is suppressed during limb regeneration, so we investigated collagen deposition and apical epithelial cap (AEC) formation during axolotl limb regeneration. The accessory limb model (ALM) has been developed as an alternative model for studying limb regeneration. Using this model, we investigated the relationship between nerves, epidermis, and collagen deposition. We found that Sp-9, an AEC marker gene, was upregulated by direct interaction between nerves and epidermis. However, collagen deposition hindered this interaction, and resulted in the failure of limb regeneration. During wound healing, an increase in deposition of collagen caused a decrease in the blastema induction rate in ALM. Wound healing and limb regeneration are alternate processes.

  2. Environmental Restoration of Diesel-Range Organics from Project Chariot, Cape Thompson, Alaska

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kautsky, Mark; Hutton, Rick; Miller, Judy

    The Chariot site is located in the Ogotoruk Valley in the Cape Thompson region of northwest Alaska. Project Chariot was part of the Plowshare Program, created in 1957 by the US Atomic Energy Commission (AEC), a predecessor agency of the US Department of Energy (DOE), to study peaceful uses for atomic energy. Project Chariot began in 1958 when a scientific field team chose Cape Thompson as a potential site to excavate a harbor using a series of nuclear explosions. AEC, with assistance from other agencies, conducted more than 40 pretest bioenvironmental studies of the Cape Thompson area between 1959 andmore » 1962; however, the Plowshare Program work at the Project Chariot site (Figure 1) was cancelled because of strong public opposition [1]. No nuclear explosions were ever conducted at the site.« less

  3. Nitrogen-Doped Holey Graphene Film-Based Ultrafast Electrochemical Capacitors.

    PubMed

    Zhou, Qinqin; Zhang, Miao; Chen, Ji; Hong, Jong-Dal; Shi, Gaoquan

    2016-08-17

    The commercialized aluminum electrolytic capacitors (AECs) currently used for alternating current (AC) line-filtering are usually the largest components in the electronic circuits because of their low specific capacitances and bulky sizes. Herein, nitrogen-doped holey graphene (NHG) films were prepared by thermal annealing the composite films of polyvinylpyrrolidone (PVP), graphene oxide (GO), and ferric oxide (Fe2O3) nanorods followed by chemical etching with hydrochloride acid. The typical electrochemical capacitor with NHG electrodes exhibited high areal and volumetric specific capacitances of 478 μF cm(-2) and 1.2 F cm(-3) at 120 Hz, ultrafast frequency response with a phase angle of -81.2° and a resistor-capacitor time constant of 203 μs at 120 Hz, as well as excellent cycling stability. Thus, it is promising to replace conventional AEC for AC line-filtering in miniaturized electronics.

  4. VENTED FUEL ELEMENT FOR GAS-COOLED NEUTRONIC REACTORS

    DOEpatents

    Furgerson, W.T.

    1963-12-17

    A hollow, porous-walled fuel element filled with fissionable fuel and provided with an outlet port through its wall is described. In operation in a gas-cooled reactor, the element is connected, through its outlet port, to the vacuum side of a pump that causes a portion of the coolant gas flowing over the exterior surface of the element to be drawn through the porous walls thereof and out through the outlet port. This continuous purging gas flow sweeps away gaseous fission products as they are released by the fissioning fuel. (AEC) A fuel element for a nuclear reactor incorporating a body of metal of melting point lower than the temperature of operation of the reactor and a nuclear fuel in finely divided form dispersed in the body of metal as a settled slurry is presented. (AEC)

  5. Mechanical Testing of MLCCs

    NASA Technical Reports Server (NTRS)

    Teverovsky, Alexander A.

    2016-01-01

    Cracking of multilayer ceramic capacitors, MLCCs, remains a serious problem for space systems. This problem increases substantially for large size capacitors and in cases when manual soldering is involved or the system experiences mechanical shock or vibration. In any case, a fracture occurs when the sum of external and internal mechanical stresses exceeds the strength of the part. To reduce the probability of cracking, the level of stress should be reduced, e.g. by optimizing the assembly workmanship and rules for board design, and the strength of the parts increased by selecting the most mechanically robust capacitors. The latter might possibly be achieved by selecting MLCCs based on the in-situ measurements of mechanical characteristics using four types of tests: flexural strength, hardness, fracture toughness, and flex bend testing. Note that military specifications MIL-PRF-123 and MIL-PRF-55681 do not have requirements for mechanical testing of the parts. However, specifications for automotive industry components employ two types of mechanical tests: beam load (break strength) test per AEC-Q200-003 and board flex test per AEC-Q200-005. A recent military specification for thin dielectric capacitors, MIL-PRF-32535, has one mechanical test, board flex testing, that is similar to AEC-Q200-005. The purpose of this report was assessment of the efficiency of different mechanical tests for selection robust capacitors and comparison of mechanical characteristics of Base Metal Electrode (BME) and Precious Metal Electrode (PME) capacitors. The report has three parts related to the first three mechanical tests mentioned above.

  6. Placental stem cell correction of murine intermediate maple syrup urine disease.

    PubMed

    Skvorak, Kristen J; Dorko, Kenneth; Marongiu, Fabio; Tahan, Veysel; Hansel, Marc C; Gramignoli, Roberto; Gibson, K Michael; Strom, Stephen C

    2013-03-01

    There is improved survival and partial metabolic correction of a mouse intermediate maple syrup urine disease (iMSUD) model after allogenic hepatocyte transplantation, confirming that a small number of enzyme-proficient liver-engrafted cells can improve phenotype. However, clinical shortages of suitable livers for hepatocyte isolation indicate a need for alternative cell sources. Human amnion epithelial cells (hAECs) share stem cell characteristics without the latter's safety and ethical concerns and differentiate to hepatocyte-like cells. Eight direct hepatic hAEC transplantations were performed in iMSUD mice over the first 35 days beginning at birth; animals were provided a normal protein diet and sacrificed at 35 and 100 days. Treatment at the neonatal stage is clinically relevant for MSUD and may offer a donor cell engraftment advantage. Survival was significantly extended and body weight was normalized in iMSUD mice receiving hAEC transplantations compared with untreated iMSUD mice, which were severely cachectic and died ≤28 days after birth. Branched chain α-keto acid dehydrogenase enzyme activity was significantly increased in transplanted livers. The branched chain amino acids leucine, isoleucine, valine, and alloisoleucine were significantly improved in serum and brain, as were other large neutral amino acids. Placental-derived stem cell transplantation lengthened survival and corrected many amino acid imbalances in a mouse model of iMSUD. This highlights the potential for their use as a viable alternative clinical therapy for MSUD and other liver-based metabolic diseases. Copyright © 2012 American Association for the Study of Liver Diseases.

  7. Placental Stem Cell Correction of Murine Intermediate Maple Syrup Urine Disease

    PubMed Central

    Skvorak, Kristen J.; Dorko, Kenneth; Marongiu, Fabio; Tahan, Veysel; Hansel, Marc C.; Gramignoli, Roberto; Gibson, K. Michael; Strom, Stephen C.

    2012-01-01

    We previously reported improved survival and partial metabolic correction of a mouse intermediate maple syrup urine disease (iMSUD) model post allogenic hepatocyte transplant, confirming that a small number of enzyme proficient liver-engrafted cells can improve phenotype. However, clinical shortages of suitable livers for hepatocyte isolation indicate a need for alternative cell sources. Human amnion epithelial cells (hAEC) share stem cell characteristics while lacking many safety and ethical concerns, and differentiate to hepatocyte-like cells. Eight direct hepatic hAEC transplants were administered to iMSUD mice over the first 35 days beginning at birth; animals were provided a normal protein diet and sacrificed at days 35 and 100. Treatment at the neonatal stage is clinically relevant for MSUD, and may offer a donor cell engraftment advantage. Survival was significantly extended and body weight was normalized in iMSUD mice receiving hAEC transplants compared to iMSUD (severely cachectic; dead ≤28 days). Branched chain α-keto acid dehydrogenase enzyme activity was significantly increased in transplanted livers. Branched chain amino acids leucine, isoleucine, valine, and alloisoleucine were significantly improved in the sera and brain, as were other large neutral amino acids. Conclusion: Placental-derived stem cell transplantation lengthened survival and corrected many amino acid imbalances in a mouse model of iMSUD. This highlights the potential for their use as a viable alternative clinical therapy for MSUD and other liver-based metabolic diseases. PMID:23175463

  8. [Predictive ability of clinical parameters of bacteremia in hemodialysed patients].

    PubMed

    Egea, Ana L; Vilaró, Mario; De la Fuente, Jorge; Cuestas, Eduardo; Bongiovanni, María E

    2012-01-01

    No clinical events to differentiate bacteteremia from other pathologies in hemodialysis patients therefore the physicians makes diagnosis and treatment decisions based on clinical evidence an local epidemiology. the aim of this work was to study the frequency of microorganism isolated from blood culture of hemodialysis patients with suspected bacteraemia and evaluate Sensitivity (S) and Specificity (E) of medical diagnostic orientation in this cases of suspected Materials and methods: we performed an observational and prospective study for one year in hemodialysis patient with suspected bacteremia. We evaluated blood pressure, temperature (Tº), altered conscious state (AEC), respiratory frequency (FR), chills (ESC),diarrhea (DIARR), blood culture results and microbiological identification. We work with the mean ± standar desviation for continuous variables and frequencies for categorical variables We analyzed S, E, negative predictive value (VPN), positive predictive value (VPP) RESULTADOS: a total of 87 events with suspected bacteremia 34 (39%) were confirmed with positive blood culture the most common microorganisms were cocci Gram positive (CGP) 65%, Most relevant clinical variables were PCP ≥ 2 (VPN 81%), Tº ≥ 38 (VPN 76%) and AEC (E 98% y VPP 80%). CGP were the most prevalent microorganisms None of the clinical variables shows high S and E indicating low usefulness as a predictive tool of bacteremia Excepting AEC with E98% and VPP 80% but it would be necessary to evaluate this variable with a more number patient. Results justify to routine HC use like diagnostic tool.

  9. Effect of anticoagulants on the protein corona-induced reduced drug carrier adhesion efficiency in human blood flow.

    PubMed

    Sobczynski, Daniel J; Eniola-Adefeso, Omolola

    2017-01-15

    Plasma proteins rapidly coat the surfaces of particulate drug carriers to form a protein corona upon their injection into the bloodstream. The high presence of immunoglobulins in the corona formed on poly(lactic-co-glycolic acid) (PLGA) vascular-targeted carrier (VTC) surfaces was recently shown to negatively impact their adhesion to activated endothelial cells (aECs) in vitro. Here, we characterized the influence of anticoagulants, or their absence, on the binding efficiency of VTCs of various materials via modulation of their protein corona. Specifically, we evaluated the adhesion of PLGA, poly(lactic acid) (PLA), polycaprolactone (PCL), silica, and polystyrene VTCs to aECs in heparinized, citrated, and non-anticoagulated (serum and whole) blood flows relative to buffer control. Particle adhesion is substantially reduced in non-anticoagulated blood flows regardless of the material type while only moderate to minimal reduction is observed for VTCs in anticoagulant-containing blood flow depending on the anticoagulant and material type. The substantial reduction in VTC adhesion in blood flows was linked to a high presence of immunoglobulin-sized proteins in the VTC corona via SDS-PAGE analysis. Of all the materials evaluated, PLGA was the most sensitive to plasma protein effects while PCL was the most resistant, suggesting particle hydrophobicity is a critical component of the observed negative plasma protein effects. Overall, this work demonstrates that anticoagulant positively alters the effect of plasma proteins in prescribing VTC adhesion to aECs in human blood flow, which has implication in the use of in vitro blood flow assays for functional evaluation of VTCs for in vivo use. This study addresses the impact of anticoagulant on altering the extent of the previously observed protein corona-induced adhesion reduction of vascular-targeted drug carriers in human blood flows. Specifically, serum blood flow (no anticoagulant) magnifies the negative effect of the plasma protein corona on drug carrier adhesion relative to citrated or heparinized blood flows. Overall, the results from this work suggest that serum better predicts targeted drug carrier adhesion efficiency in vivo compared to anticoagulant containing plasma. Furthermore, this study offers critical insight into the importance of how the choice of anticoagulant can greatly affect drug delivery-related processes in vitro. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  10. [Liver transplant with donated graft after controlled cardiac death. Current situation].

    PubMed

    Abradelo De Usera, Manuel; Jiménez Romero, Carlos; Loinaz Segurola, Carmelo; Moreno González, Enrique

    2013-11-01

    An increasing pressure on the liver transplant waiting list, forces us to explore new sources, in order to expand the donor pool. One of the most interesting and with a promising potential, is donation after cardiac death (DCD). Initially, this activity has developed in Spain by means of the Maastricht type II donation in the uncontrolled setting. For different reasons, donation after controlled cardiac death has been reconsidered in our country. The most outstanding circumstance involved in DCD donation is a potential ischemic stress, that could cause severe liver graft cell damage, resulting in an adverse effect on liver transplant results, in terms of complications and outcomes. The complex and particular issues related to DCD Donation will be discussed in this review. Copyright © 2012 AEC. Published by Elsevier Espana. All rights reserved.

  11. SEPARATION OF CURIUM AND AMERICIUM

    DOEpatents

    Fields, P.R.; Isaac, N.M.

    1962-02-20

    Curium and americium are contained in an anhydrous molten salt medium having a low melting point. Curium is preferentially extracted from the molten salt by a hot organic solvent containing preferably less than 10% alkyl phosphate. (AEC)

  12. FUEL ELEMENTS FOR NEUTRONIC REACTORS

    DOEpatents

    Foote, F.G.; Jette, E.R.

    1963-05-01

    A fuel element for a nuclear reactor is described that consists of a jacket containing a unitary core of fissionable material and a filling of a metal of the group consisting of sodium and sodium-potassium alloys. (AEC)

  13. AUTOMATIC MASS SPECTROMETER

    DOEpatents

    Hanson, M.L.; Tabor, C.D. Jr.

    1961-12-01

    A mass spectrometer for analyzing the components of a gas is designed which is capable of continuous automatic operation such as analysis of samples of process gas from a continuous production system where the gas content may be changing. (AEC)

  14. 78 FR 22302 - United States v. United Technologies Corporation and Goodrich Corporation; Public Comments and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-15

    ..., UTC and Rolls-Royce were to use AEC to combine their ECS intellectual property and research and development results, rather than competing independently to develop innovative and cost- effective ECS...

  15. GRAPHITE BONDING METHOD

    DOEpatents

    King, L.D.P.

    1964-02-25

    A process for bonding or joining graphite members together in which a thin platinum foil is placed between the members, heated in an inert atmosphere to a temperature of 1800 deg C, and then cooled to room temperature is described. (AEC)

  16. Electronic construction collaboration system : phase III.

    DOT National Transportation Integrated Search

    2011-12-01

    This phase of the electronic collaboration project involved two major efforts: 1) implementation of AEC Sync (formerly known as Attolist), a web-based project management system (WPMS), on the Broadway Viaduct Bridge Project and the Iowa Falls Arch Br...

  17. NASA Reactor Facility Hazards Summary. Volume 2

    NASA Technical Reports Server (NTRS)

    1959-01-01

    Supplements to volume 1 are presented herein. Included in these papers are information unavailable when volume 1 was written, an evaluation of the proposed nuclear facility, and answers to questions raised by the AEC concerning volume 1.

  18. METHOD OF SUPPRESSING GASTROINTESTINAL UREASE ACTIVITY

    DOEpatents

    Visek, W.J.

    1963-04-23

    This patent shows a method of increasing the growth rate of chicks. Certain diacyl substituted ureas such as alloxan, murexide, and barbituric acid are added to their feed, thereby suppressing gastrointestinal urease activity and thus promoting growth. (AEC)

  19. ZIRCONIUM-CLADDING OF THORIUM

    DOEpatents

    Beaver, R.J.

    1961-11-21

    A method of cladding thorium with zirconium is described. The quality of the bond achieved between thorium and zirconium by hot-rolling is improved by inserting and melting a thorium-zirconium alloy foil between the two materials prior to rolling. (AEC)

  20. METHOD OF MAKING SPHERICAL ACTINIDE CARBIDE

    DOEpatents

    White, G.D.; O'Rourke, D.C.

    1962-12-25

    This patent describes a method of making uniform, spherical, nonpyrophoric UC. UO/sub 2/ and carbon are mixed in stoichiometric proportions and passed through a plasma flame of inert gas at 10,000 to 13,000 deg C. (AEC)

  1. Seventeenth Semiannual Report of the Commission to the Congress, January 1955

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strauss, Lewis L.

    The document represents the seventeenth semiannual Atomic Energy Commission (AEC) report to Congress. The report sums up the major activities and developments in the national atomic energy program covering the period July - December 1954.

  2. Nineteenth Semiannual Report of the Commission to the Congress, January 1956

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strauss, Lewis L.

    The document represents the nineteenth semiannual Atomic Energy Commission (AEC) report to Congress. The report sums up the major activities and developments in the national atomic energy program covering the period July - December 1955.

  3. Patent policies affecting ERDA energy programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1976-01-01

    Appendix A, Patent Policy, and Appendix B, Procurement Regulation and Public Comments Thereon, are presented. The sixteen parts of Appendix A are Section 9 of the Nonnuclear Energy Act; Sections 151-160 of the Atomic Energy Act; 1963 Presidential Statement; 1968 Government Patent Policy Report to FCST; Dept. of Justice Minority Report to FCST; 1971 Presidential Statement; Federal Procurement Regulations: Subpart 1-9.1 - Patents; Federal Property Management Regulations: Subpart 104-4.1; Patent Licensing Regulations for AEC-Owned Inventions; Consent Judgement - Nuclear Data v. AEC; Section 112, S. 1283 (1973); Hart - Long Amendment to S. 1283 (1973); Section 7, H.R. 13565 (1974);more » H.R. Rep. No. 1563, Nonnuclear Conference Report; Report on Background Patent Rights; and Revised Report on Background Patent Rights. The four parts of Appendix B are ERDA-PR Temporary Regulations; ERDA-PR Proposed Policies and Procedures; Public Comments Annotated to ERDA-PR; and Written Comments (Letters). (MCW)« less

  4. Low-Dose Paclitaxel Ameliorates Pulmonary Fibrosis by Suppressing TGF-β1/Smad3 Pathway via miR-140 Upregulation

    PubMed Central

    Wang, Congjie; Song, Xiaodong; Li, Youjie; Han, Fang; Gao, Shuyan; Wang, Xiaozhi; Xie, Shuyang; Lv, Changjun

    2013-01-01

    Abnormal TGF-β1/Smad3 activation plays an important role in the pathogenesis of pulmonary fibrosis, which can be prevented by paclitaxel (PTX). This study aimed to investigate an antifibrotic effect of the low-dose PTX (10 to 50 nM in vitro, and 0.6 mg/kg in vivo). PTX treatment resulted in phenotype reversion of epithelial-mesenchymal transition (EMT) in alveolar epithelial cells (AECs) with increase of miR-140. PTX resulted in an amelioration of bleomycin (BLM)-induced pulmonary fibrosis in rats with reduction of the wet lung weight to body weight ratios and the collagen deposition. Our results further demonstrated that PTX inhibited the effect of TGF-β1 on regulating the expression of Smad3 and phosphorylated Smad3 (p-Smad3), and restored the levels of E-cadherin, vimentin and α-SMA. Moreover, lower miR-140 levels were found in idiopathic pulmonary fibrosis (IPF) patients, TGF-β1-treated AECs and BLM-instilled rat lungs. Through decreasing Smad3/p-Smad3 expression and upregulating miR-140, PTX treatment could significantly reverse the EMT of AECs and prevent pulmonary fibrosis of rats. The action of PTX to ameliorate TGF-β1-induced EMT was promoted by miR-140, which increased E-cadherin levels and reduced the expression of vimentin, Smad3 and p-Smad3. Collectively, our results demonstrate that low-dose PTX prevents pulmonary fibrosis by suppressing the TGF-β1/Smad3 pathway via upregulating miR-140. PMID:23967091

  5. Individual and Medical Characteristics of Adults Presenting to an Urban Emergency Department in Ghana.

    PubMed

    Oteng, R A; Whiteside, L K; Rominski, S D; Amuasi, J H; Carter, P M; Donkor, P; Cunningham, R

    2015-09-01

    The aims of this study were to characterize the patients seeking acute care for injury and non-injury complaints in an urban Emergency Department in Ghana in order to 1) inform the curriculum of the newly developed Emergency Medicine resident training program 2) improve treatment processes, and 3) direct future community-wide injury prevention policies. A prospective cross-sectional survey of patients 18 years or older seeking care in an urban Accident and Emergency Center (AEC) was conducted between 7/13/2009 and 7/30/2009. Questionnaires were administered by trained research staff and each survey took 10-15 minutes to complete. Patients were asked questions regarding demographics, overall health and chief complaint. 254 patients were included in the sample. Participants' chief complaints were classified as either medical or injury-related. Approximately one third (38%) of patients presented with injuries and 62% presented for medical complaints. The most common injury at presentation was due to a road traffic injury, followed by falls and assault/fight. The most common medical presentation was abdominal pain followed by difficulty breathing and fainting/ blackout. Only 13% arrived to AEC by ambulance and 51% were unable to ambulate at the time of presentation. Approximately one-third of non-fatal adult visits were for acute injury. Future research should focus on developing surveillance systems for both medical and trauma patients. Physicians that are specifically trained to manage both the acutely injured patient and the medical patient will serve this population well given the variety of patients that seek care at the AEC.

  6. IgA and IgM protein primarily drive plasma corona-induced adhesion reduction of PLGA nanoparticles in human blood flow.

    PubMed

    Sobczynski, Daniel J; Eniola-Adefeso, Omolola

    2017-06-01

    The high abundance of immunoglobulins (Igs) in the plasma protein corona on poly(lactic-co-glycolic) acid (PLGA)-based vascular-targeted carriers (VTCs) has previously been shown to reduce their adhesion to activated endothelial cells (aECs) in human blood flow. However, the relative role of individual Ig classes (e.g., IgG, IgA, and IgM) in causing adhesion reduction remains largely unknown. Here, we characterized the influence of specific Ig classes in prescribing the binding efficiency of PLGA nano-sized VTCs in blood flow. Specifically, we evaluated the flow adhesion to aECs of PLGA VTCs with systematic depletion of various Igs in their corona. Adhesion reduction was largely eliminated for PLGA VTCs when all Igs were removed from the corona. Furthermore, re-addition of IgA or IgM to the Igs-depleted corona reinstated the low adhesion of PLGA VTCs, as evidenced by ∼40-70% reduction relative to particles with an Igs-deficient corona. However, re-addition of a high concentration of IgG to the Igs-depleted corona did not cause significant adhesion reduction. Overall, the presented results reveal that PLGA VTC adhesion reduction in blood flows is primarily driven by high adsorption of IgA and IgM in the particle corona. Pre-coating of albumin on PLGA VTCs mitigated the extent of adhesion reduction in plasma for some donors but was largely ineffective in general. Overall, this work may shed light into effective control of protein corona composition, thereby enhancing VTC functionality in vivo for eventual clinical use.

  7. Accounting for patient size in the optimization of dose and image quality of pelvis cone beam CT protocols on the Varian OBI system.

    PubMed

    Wood, Tim J; Moore, Craig S; Horsfield, Carl J; Saunderson, John R; Beavis, Andrew W

    2015-01-01

    The purpose of this study was to develop size-based radiotherapy kilovoltage cone beam CT (CBCT) protocols for the pelvis. Image noise was measured in an elliptical phantom of varying size for a range of exposure factors. Based on a previously defined "small pelvis" reference patient and CBCT protocol, appropriate exposure factors for small, medium, large and extra-large patients were derived which approximate the image noise behaviour observed on a Philips CT scanner (Philips Medical Systems, Best, Netherlands) with automatic exposure control (AEC). Selection criteria, based on maximum tube current-time product per rotation selected during the radiotherapy treatment planning scan, were derived based on an audit of patient size. It has been demonstrated that 110 kVp yields acceptable image noise for reduced patient dose in pelvic CBCT scans of small, medium and large patients, when compared with manufacturer's default settings (125 kVp). Conversely, extra-large patients require increased exposure factors to give acceptable images. 57% of patients in the local population now receive much lower radiation doses, whereas 13% require higher doses (but now yield acceptable images). The implementation of size-based exposure protocols has significantly reduced radiation dose to the majority of patients with no negative impact on image quality. Increased doses are required on the largest patients to give adequate image quality. The development of size-based CBCT protocols that use the planning CT scan (with AEC) to determine which protocol is appropriate ensures adequate image quality whilst minimizing patient radiation dose.

  8. Partial pneumonectomy of telomerase null mice carrying shortened telomeres initiates cell growth arrest resulting in a limited compensatory growth response

    PubMed Central

    Jackson, Sha-Ron; Lee, Jooeun; Reddy, Raghava; Williams, Genevieve N.; Kikuchi, Alexander; Freiberg, Yael; Warburton, David

    2011-01-01

    Telomerase mutations and significantly shortened chromosomal telomeres have recently been implicated in human lung pathologies. Natural telomere shortening is an inevitable consequence of aging, which is also a risk factor for development of lung disease. However, the impact of shortened telomeres and telomerase dysfunction on the ability of lung cells to respond to significant challenge is still largely unknown. We have previously shown that lungs of late generation, telomerase null B6.Cg-Terctm1Rdp mice feature alveolar simplification and chronic stress signaling at baseline, a phenocopy of aged lung. To determine the role telomerase plays when the lung is challenged, B6.Cg-Terctm1Rdp mice carrying shortened telomeres and wild-type controls were subjected to partial pneumonectomy. We found that telomerase activity was strongly induced in alveolar epithelial type 2 cells (AEC2) of the remaining lung immediately following surgery. Eighty-six percent of wild-type animals survived the procedure and exhibited a burst of early compensatory growth marked by upregulation of proliferation, stress response, and DNA repair pathways in AEC2. In B6.Cg-Terctm1Rdp mice carrying shortened telomeres, response to pneumonectomy was characterized by decreased survival, diminished compensatory lung growth, attenuated distal lung progenitor cell response, persistent DNA damage, and cell growth arrest. Overall, survival correlated strongly with telomere length. We conclude that functional telomerase and properly maintained telomeres play key roles in both long-term survival and the early phase of compensatory lung growth following partial pneumonectomy. PMID:21460122

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roychoudhury, Sanghita; Mondal, Nandan Kumar; Mukherjee, Sayali

    The impact of indoor air pollution (IAP) from biomass fuel burning on the risk of carcinogenesis in the airways has been investigated in 187 pre-menopausal women (median age 34 years) from eastern India who cooked exclusively with biomass and 155 age-matched control women from same locality who cooked with cleaner fuel liquefied petroleum gas. Compared with control, Papanicolau-stained sputum samples showed 3-times higher prevalence of metaplasia and 7-times higher prevalence of dysplasia in airway epithelial cell (AEC) of biomass users. Immunocytochemistry showed up-regulation of phosphorylated Akt (p-Akt{sup ser473} and p-Akt{sup thr308}) proteins in AEC of biomass users, especially in metaplasticmore » and dysplastic cells. Compared with LPG users, biomass-using women showed marked rise in reactive oxygen species (ROS) generation and depletion of antioxidant enzyme, superoxide dismutase (SOD) indicating oxidative stress. There were 2–5 times more particulate pollutants (PM{sub 10} and PM{sub 2.5}), 72% more nitrogen dioxide and 4-times more particulate-laden benzo(a)pyrene, but no change in sulfur dioxide in indoor air of biomass-using households, and high performance liquid chromatography estimated 6-fold rise in the concentration of benzene metabolite trans,trans-muconic acid (t,t-MA) in urine of biomass users. Metaplasia and dysplasia, p-Akt expression and ROS generation were positively associated with PM and t,t-MA levels. It appears that cumulative exposure to biomass smoke increases the risk of lung carcinogenesis via oxidative stress-mediated activation of Akt signal transduction pathway. -- Highlights: ► Carcinogenesis in airway cells was examined in biomass and LPG using women. ► Metaplasia and dysplasia of epithelial cells were more prevalent in biomass users. ► Change in airway cytology was associated with oxidative stress and Akt activation. ► Biomass users had greater exposure to respirable PM, B(a)P and benzene. ► Cooking with biomass increases cancer risk in the airways via Akt activation.« less

  10. Neutronic Reactor Structure

    DOEpatents

    Vernon, H. C.; Weinberg, A. M.

    1961-05-30

    The neutronic reactor is comprised of a core consisting of natural uranium and heavy water with a K-factor greater than unity. The core is surrounded by a reflector consisting of natural uranium and ordinary water with a Kfactor less than unity. (AEC)

  11. PREPARATION OF PuF$sub 3$

    DOEpatents

    Benz, R.

    1964-03-01

    A process for preparing pure plutonium trifluoride is described in which a refractory plutonium compound is contacted with ammonium fluoride in a closed container at a pressure of at least 10 atmospheres and a temperature of about 550 deg C. (AEC)

  12. NUCLEAR REACTOR FUEL-BREEDER FUEL ELEMENT

    DOEpatents

    Currier, E.L. Jr.; Nicklas, J.H.

    1962-08-14

    A fuel-breeder fuel element was developed for a nuclear reactor wherein discrete particles of fissionable material are dispersed in a matrix of fertile breeder material. The fuel element combines the advantages of a dispersion type and a breeder-type. (AEC)

  13. EXPERIMENTAL ANIMAL MAINTENANCE

    DOEpatents

    Finkel, M.P.

    1962-01-22

    A method of housing experimental animals such as mice in individual tube- like plastic enclosures is described. Contrary to experience, when this was tried with metal the mice did not become panicky. Group housing, with its attendant difficulties, may thus be dispensed with. (AEC)

  14. PROCESS OF RECOVERING ALKALI METALS

    DOEpatents

    Wolkoff, J.

    1961-08-15

    A process is described of recovering alkali metal vapor by sorption on activated alumina, activated carbon, dehydrated zeolite, activated magnesia, or Fuller's earth preheated above the vaporization temperature of the alkali metal and subsequent desorption by heating the solvent under vacuum. (AEC)

  15. NUCLEAR POWER PLANT

    DOEpatents

    Carter, J.C.; Armstrong, R.H.; Janicke, M.J.

    1963-05-14

    A nuclear power plant for use in an airless environment or other environment in which cooling is difficult is described. The power plant includes a boiling mercury reactor, a mercury--vapor turbine in direct cycle therewith, and a radiator for condensing mercury vapor. (AEC)

  16. Twenty-fourth Semiannual Report of the Commission to the Congress, July 1958

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strauss, Lewis L.; McCone, John A.

    1958-07-31

    The document represents the twenty-fourth semiannual Atomic Energy Commission (AEC) report to Congress. The report sums up the major activities and developments in the national atomic energy program covering the period January - June 1958.

  17. PREPARATION OF PURE METAL FROM THEIR COMPOUNDS

    DOEpatents

    Slatin, H.L.

    1961-08-01

    S>A method is described for the preparation of uranium from U/sub 3/O/ sub 6/ by electrolytic deposition at the cathode from an alkali and/or alkaline earth fused salt bath such as fused strontium potassium chloride. (AEC)

  18. CADMIUM PHOSPHATE GLASS

    DOEpatents

    Carpenter, H.W.; Johnson, P.D.

    1963-04-01

    A method of preparing a cadmium phosphate glass that comprises providing a mixture of solid inorganic compounds of cadmuim and phosphate having vaporizable components and heating the resulting composition to a temperature of at least 850 un. Concent 85% C is presented. (AEC)

  19. Definitive Chemoradiation Therapy With Docetaxel, Cisplatin, and 5-Fluorouracil (DCF-R) in Advanced Esophageal Cancer: A Phase 2 Trial (KDOG 0501-P2)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Higuchi, Katsuhiko, E-mail: k.higu@kitasato-u.ac.jp; Komori, Shouko; Tanabe, Satoshi

    Purpose: A previous phase 1 study suggested that definitive chemoradiation therapy with docetaxel, cisplatin, and 5-fluorouracil (DCF-R) is tolerable and active in patients with advanced esophageal cancer (AEC). This phase 2 study was designed to confirm the efficacy and toxicity of DCF-R in AEC. Methods and Materials: Patients with previously untreated thoracic AEC who had T4 tumors or M1 lymph node metastasis (M1 LYM), or both, received intravenous infusions of docetaxel (35 mg/m{sup 2}) and cisplatin (40 mg/m{sup 2}) on day 1 and a continuous intravenous infusion of 5-fluorouracil (400 mg/m{sup 2}/day) on days 1 to 5, every 2 weeks,more » plus concurrent radiation. The total radiation dose was initially 61.2 Gy but was lowered to multiple-field irradiation with 50.4 Gy to decrease esophagitis and late toxicity. Consequently, the number of cycles of DCF administered during radiation therapy was reduced from 4 to 3. The primary endpoint was the clinical complete response (cCR) rate. Results: Characteristics of the 42 subjects were: median age, 62 years; performance status, 0 in 14, 1 in 25, 2 in 3; TNM classification, T4M0 in 20, non-T4M1LYM in 12, T4M1LYM in 10; total scheduled radiation dose: 61.2 Gy in 12, 50.4 Gy in 30. The cCR rate was 52.4% (95% confidence interval [CI]: 37.3%-67.5%) overall, 33.3% in the 61.2-Gy group, and 60.0% in the 50.4-Gy group. The median progression-free survival was 11.1 months, and the median survival was 29.0 months with a survival rate of 43.9% at 3 years. Grade 3 or higher major toxicity consisted of leukopenia (71.4%), neutropenia (57.2%), anemia (16.7%), febrile neutropenia (38.1%), anorexia (31.0%), and esophagitis (28.6%). Conclusions: DCF-R frequently caused myelosuppression and esophagitis but was highly active and suggested to be a promising regimen in AEC. On the basis of efficacy and safety, a radiation dose of 50.4 Gy is recommended for further studies of DCF-R.« less

  20. 2014 Well Completion Report for Corrective Action Unit 447 Project Shoal Area Churchill County, Nevada October 2015

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Findlay, Rick

    2015-11-01

    This report summarizes the drilling program conducted by the U.S. Department of Energy (DOE) Office of Legacy Management at the Project Shoal Area (Shoal) Subsurface Corrective Action Unit 447 in Churchill County, Nevada. Shoal was the location of an underground nuclear test conducted on October 26, 1963, as part of the Vela Uniform program sponsored jointly by the U.S. Department of Defense and the U.S. Atomic Energy Commission (a predecessor to DOE). The test consisted of detonating a 12-kiloton nuclear device in granitic rock at a depth of approximately 1,211 feet (ft) below ground surface (bgs) (AEC 1964). The correctivemore » action strategy for the site is focused on revising the site conceptual model and evaluating the adequacy of the monitoring well network at the site. Field activities associated with the project were conducted in accordance with the Federal Facility Agreement and Consent Order (FFACO 1996, as amended) and applicable Nevada Division of Environmental Protection (NDEP) policies and regulations.« less

  1. ACCELERATION INTEGRATING MEANS

    DOEpatents

    Wilkes, D.F.

    1961-08-29

    An acceleration responsive device is described. A housing has at one end normally open electrical contacts and contains a piston system with a first part of non-magnetic material having metering orifices in the side walls for forming an air bearing between it and the walls of the housing; this first piston part is normally held against the other end of the housing from the noted contacts by a second piston or reset part. The reset part is of partly magnetic material, is separable from the flrst piston part, and is positioned within the housing intermediate the contacts and the first piston part. A magnet carried by the housing imposes a retaining force upon the reset part, along with a helical compression spring that is between the reset part and the end with the contacts. When a predetermined acceleration level is attained, the reset part overcomes the bias or retaining force provided by the magnet and the spring'' snaps'' into a depression in the housing adjacent the contacts. The first piston part is then free to move toward the contacts with its movement responsive tc acceleration forces and the metering orifices. (AEC)

  2. Metabolic adaptation to long term changes in gravity environment

    NASA Astrophysics Data System (ADS)

    Slenzka, K.; Appel, R.; Rahmann, H.

    Biochemical analyses of the brain of Cichlid fish larvae, exposed during their very early development for 7 days to an increased acceleration of 3g (hyper-gravity), revealed a decrease in brain nucleoside diphosphate kinase (NDPK) as well as creatine kinase (BB-CK) activity. Using high performance liquid chromatography (HPLC) the concentrations of adenine nucleotides (AMP, ADP, ATP), phosphocreatine (CP), as well as of nicotineamide adenine dinucleotides (NAD, NADP) were analyzed in the brain of hyper-g exposed larvae vs. 1g controls. A slight reduction in the total adenine nucleotides (TAN) as well as the adenylate energy charge (AEC) was found. In parallel a significant increase in the NAD concentration and a corresponding decrease in NADP concentration occurred in larva's hyper-g brains vs. 1g controls. These results give further evidence for an influence of gravity on cellular level and furthermore contribute to a clarification of the cellular signal-response chain for gravity perception.

  3. High frequency x-ray generator basics.

    PubMed

    Sobol, Wlad T

    2002-02-01

    The purpose of this paper is to present basic functional principles of high frequency x-ray generators. The emphasis is put on physical concepts that determine the engineering solutions to the problem of efficient generation and control of high voltage power required to drive the x-ray tube. The physics of magnetically coupled circuits is discussed first, as a background for the discussion of engineering issues related to high-frequency power transformer design. Attention is paid to physical processes that influence such factors as size, efficiency, and reliability of a high voltage power transformer. The basic electrical circuit of a high frequency generator is analyzed next, with focus on functional principles. This section investigates the role and function of basic components, such as power supply, inverter, and voltage doubler. Essential electronic circuits of generator control are then examined, including regulation of voltage, current and timing of electrical power delivery to the x-ray tube. Finally, issues related to efficient feedback control, including basic design of the AEC circuitry are reviewed.

  4. Electronic construction collaboration system -- final phase.

    DOT National Transportation Integrated Search

    2014-09-01

    This phase of the research project involved two major efforts: (1) Complete the implementation of AEC-Sync (formerly known as : Attolist) on the Iowa Falls Arch Bridge project and (2) develop a WPMS for projects under $10 million. : For the first maj...

  5. OXIDATION-RESISTANT COATING ON ARTICLES OF YTTRIUM METAL

    DOEpatents

    Wilder, D.R.; Wirkus, C.D.

    1963-11-01

    A process for protecting yttrium metal from oxidation by applying thereto and firing thereon a liquid suspension of a fritted ground silicate or phosphate glass plus from 5 to 35% by weight of CeO/sub 2/ is presented. (AEC)

  6. PROCESS OF DISSOLVING FUEL ELEMENTS OF NUCLEAR REACTORS

    DOEpatents

    Wall, E.M.V.; Bauer, D.T.; Hahn, H.T.

    1963-09-01

    A process is described for dissolving stainless-steelor zirconium-clad uranium dioxide fuel elements by immersing the elements in molten lead chloride, adding copper, cuprous chloride, or cupric chloride as a catalyst and passing chlorine through the salt mixture. (AEC)

  7. METHOD OF INHIBITING IRRADIATION-INDUCED VISCOSITY INCREASE OF ORGANIC FLUIDS

    DOEpatents

    Denison, G.H.; Bolt, R.O.; Kent, J.W.; Christiansen, F.A.; Carroll, J.G.

    1963-12-24

    Methods of reducing radiation-induced thickening of lubricating oils are presented. A system subjected to nuclear radiation is lubricated with an oil containing iodonaphthalene, preferably in the amount of 0.5 to 16 per cent by volume. (AEC)

  8. DUCTILE URANIUM FUEL FOR NUCLEAR REACTORS AND METHOD OF MAKING

    DOEpatents

    Zegler, S.T.

    1963-11-01

    The fabrication process for a ductile nuclear fuel alloy consisting of uranium, fissium, and from 0.25 to 1.0 wt% of silicon or aluminum or from 0.25 to 2 wt% of titanium or yttrium is presented. (AEC)

  9. VALVE

    DOEpatents

    Arkelyan, A.M.; Rickard, C.L.

    1962-04-17

    A gate valve for controlling the flow of fluid in separate concentric ducts or channels by means of a single valve is described. In one position, the valve sealing discs engage opposed sets of concentric ducts leading to the concentric pipes defining the flow channels to block flow therethrough. In another position, the discs are withdrawn from engagement with the opposed ducts and at the same time a bridging section is interposed therebetween to define concentric paths coextensive with and connecting the opposed ducts to facilitate flow therebetween. A wedge block arrangement is employed with each sealing disc to enable it to engage the ducts. The wedge block arrangement also facilitates unobstructcd withdrawal of the discs out of the intervening space between the sets of ducts. (AEC)

  10. MODULAR CORE UNITS FOR A NEUTRONIC REACTOR

    DOEpatents

    Gage, J.F. Jr.; Sherer, D.B.

    1964-04-01

    A modular core unit for use in a nuclear reactor is described. Many identical core modules can be placed next to each other to make up a complete core. Such a module includes a cylinder of moderator material surrounding a fuel- containing re-entrant coolant channel. The re-entrant channel provides for the circulation of coolant such as liquid sodium from one end of the core unit, through the fuel region, and back out through the same end as it entered. Thermal insulation surrounds the moderator exterior wall inducing heat to travel inwardly to the coolant channel. Spaces between units may be used to accommodate control rods and support structure, which may be cooled by a secondary gas coolant, independently of the main coolant. (AEC)

  11. Mammography dosimetry using an in-house developed polymethyl methacrylate phantom.

    PubMed

    Sharma, Reena; Sharma, Sunil Dutt; Mayya, Y S; Chourasiya, G

    2012-08-01

    Phantom-based measurements in mammography are well-established for quality assurance (QA) and quality control (QC) procedures involving equipment performance and comparisons of X-ray machines. Polymethyl methacrylate (PMMA) is among the best suitable materials for simulation of the breast. For carrying out QA/QC exercises in India, a mammographic PMMA phantom with engraved slots for keeping thermoluminescence dosemeters (TLD) has been developed. The radiation transmission property of the developed phantom was compared with the commercially available phantoms for verifying its suitability for mammography dosimetry. The breast entrance exposure (BEE), mean glandular dose (MGD), percentage depth dose (PDD), percentage surface dose distribution (PSDD), calibration testing of automatic exposure control (AEC) and density control function of a mammography machine were measured using this phantom. MGD was derived from the measured BEE following two different methodologies and the results were compared. The PDD and PSDD measurements were carried out using LiF: Mg, Cu, P chips. The in-house phantom was found comparable with the commercially available phantoms. The difference in the MGD values derived using two different methods were found in the range of 17.5-32.6 %. Measured depth ranges in the phantom lie between 0.32 and 0.40 cm for 75 % depth dose, 0.73 and 0.92 cm for 50 % depth dose, and 1.54 and 1.78 cm for 25 % depth dose. Higher PSDD value was observed towards chest wall edge side of the phantom, which is due to the orientation of cathode-anode axis along the chest wall to the nipple direction. Results obtained for AEC configuration testing shows that the observed mean optical density (O.D) of the phantom image was 1.59 and O.D difference for every successive increase in thickness of the phantom was within±0.15 O.D. Under density control function testing, at -2 and -1 density settings, the variation in film image O.D was within±0.15 O.D of the normal density setting '0' and at +2 and +1 density setting, it was observed to be within±0.30 O.D. This study indicates that the locally made PMMA TLD slot phantom can be used to measure various mammography QC parameters which are essentially required for better outcomes in mammography.

  12. DECONTAMINATION OF URANIUM

    DOEpatents

    Spedding, F.H.; Butler, T.A.

    1962-05-15

    A process is given for separating fission products from uranium by extracting the former into molten aluminum. Phase isolation can be accomplished by selectively hydriding the uranium at between 200 and 300 deg C and separating the hydride powder from coarse particles of fissionproduct-containing aluminum. (AEC)

  13. METHOD AND MEANS FOR SUPPORTING REACTOR FUEL CONTAINERS IN AN ASSEMBLY

    DOEpatents

    Currier, E.L. Jr.; Nicklas, J.H.; Coombs, C.A.

    1962-12-11

    This patent relates to means for supporting fuelcontaining tubes in an assembly which include grid means at either end of the fuel element assembly antl improved grid means intermediate of the ends to provide support against lateral displacement. (AEC)

  14. REMOVAL OF CESIUM FROM AQUEOUS SOLUTIONS BY ADSORPTION

    DOEpatents

    Knoll, K.C.

    1963-07-16

    A process of removing microquantities of cesium from aqueous solutions also containing macroquantities of other ions by adsorption on clinoptilolite is described. The invention resides in the pretreatment of the clinoptilolite by heating at 400 deg C and cooling prior to use. (AEC)

  15. SEPARATION OF TECHNETIUM FROM AQUEOUS SOLUTIONS BY COPRECIPITATION WITH MAGNETITE

    DOEpatents

    Rimshaw, S.J.

    1961-10-24

    A method of separating technetium in the 4+ oxidation state from an aqueous basic solution containing products of uranium fission is described. The method consists of contacting the solution with finely divided magnetite and recovering a technetium-bearing precipitate. (AEC)

  16. Environmental Pollution, A Selective Bibliography.

    ERIC Educational Resources Information Center

    Clearinghouse for Federal Scientific and Technical Information, Springfield, VA.

    This bibliography on environmental pollution is comprised primarily of reports of federally sponsored research by such departments and agencies as HEW, Interior, AEC, NASA, Defense, Transportation, and others. The reports were selected from Clearinghouse announcement journals during the period 1968 through April 1970. The bibliography contains…

  17. EXTRACTION OF TETRAVALENT PLUTONIUM VALUES WITH METHYL ETHYL KETONE, METHYL ISOBUTYL KETONE ACETOPHENONE OR MENTHONE

    DOEpatents

    Seaborg, G.T.

    1961-08-01

    A process is described for extracting tetravalent plutonium from an aqueous acid solution with methyl ethyl ketone, methyl isobutyl ketone, or acetophenone and with the extraction of either tetravalent or hexavalent plutonium into menthone. (AEC)

  18. Anti-Inflammatory Effects of Adult Stem Cells in Sustained Lung Injury: A Comparative Study

    PubMed Central

    Moodley, Yuben; Vaghjiani, Vijesh; Chan, James; Baltic, Svetlana; Ryan, Marisa; Tchongue, Jorge; Samuel, Chrishan S.; Murthi, Padma; Parolini, Ornella; Manuelpillai, Ursula

    2013-01-01

    Lung diseases are a major cause of global morbidity and mortality that are treated with limited efficacy. Recently stem cell therapies have been shown to effectively treat animal models of lung disease. However, there are limitations to the translation of these cell therapies to clinical disease. Studies have shown that delayed treatment of animal models does not improve outcomes and that the models do not reflect the repeated injury that is present in most lung diseases. We tested the efficacy of amnion mesenchymal stem cells (AM-MSC), bone marrow MSC (BM-MSC) and human amniotic epithelial cells (hAEC) in C57BL/6 mice using a repeat dose bleomycin-induced model of lung injury that better reflects the repeat injury seen in lung diseases. The dual bleomycin dose led to significantly higher levels of inflammation and fibrosis in the mouse lung compared to a single bleomycin dose. Intravenously infused stem cells were present in the lung in similar numbers at days 7 and 21 post cell injection. In addition, stem cell injection resulted in a significant decrease in inflammatory cell infiltrate and a reduction in IL-1 (AM-MSC), IL-6 (AM-MSC, BM-MSC, hAEC) and TNF-α (AM-MSC). The only trophic factor tested that increased following stem cell injection was IL-1RA (AM-MSC). IL-1RA levels may be modulated by GM-CSF produced by AM-MSC. Furthermore, only AM-MSC reduced collagen deposition and increased MMP-9 activity in the lung although there was a reduction of the pro-fibrogenic cytokine TGF-β following BM-MSC, AM-MSC and hAEC treatment. Therefore, AM-MSC may be more effective in reducing injury following delayed injection in the setting of repeated lung injury. PMID:23936322

  19. Twitter® use and its implications in Spanish Association of Surgeons meetings and congresses.

    PubMed

    Segura Sampedro, Juan José; Morales Soriano, Rafael; Ramos Rodríguez, José Luis; González-Argenté, Francisco Javier; Mayol, Julio

    The use of web 2.0 tools and especially Twitter is in full expansion. Twitter has jumped from the personal field to the professional with great success, joining as a means of regular dissemination in scientific congresses. The use of Twitter from 2013 to 2016 was monitored at the congresses of the Spanish Association of Surgeons (AEC). To do this, the hashtags (# rnc13, # cnc14, # rnc15, # cncirugia16) were analyzed through various websites for analysis of hashtags. The use of Twitter among the members of the Spanish Association of Surgeons has increased clearly, surpassing other American societies. It has increased in number of tweets, in number of tweeters and in the ratio of the same with respect to those attending congresses. While at the beginning the majority of tweets (65%) were the responsibility of a group of influencers, in recent years, due to the increase in tweets, the maximum influencers are only responsible for 35% of tweets. The number of institutional accounts in the top 10 has also been reduced. n the AEC the use of twitter has grown clearly and almost exponentially in recent years. Although initially the tweeted community was small and a few were responsible for a majority of tweets, the progressive growth and penetration of twitter has made that in recent congresses, these influencers and institutional accounts are no longer the main driver of the use of twitter in the congresses. Given the global trend and the Spanish Association of Surgeons, it is expected that tools such as Twitter play an increasingly important role in the management and transmission of knowledge, as well as in the creation of collaborative networks between professionals. Copyright © 2018 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Cigarette smoke induced genotoxicity and respiratory tract pathology: evidence to support reduced exposure time and animal numbers in tobacco product testing

    PubMed Central

    Dalrymple, Annette; Ordoñez, Patricia; Thorne, David; Walker, David; Camacho, Oscar M.; Büttner, Ansgar; Dillon, Debbie; Meredith, Clive

    2016-01-01

    Abstract Many laboratories are working to develop in vitro models that will replace in vivo tests, but occasionally there remains a regulatory expectation of some in vivo testing. Historically, cigarettes have been tested in vivo for 90 days. Recently, methods to reduce and refine animal use have been explored. This study investigated the potential of reducing animal cigarette smoke (CS) exposure to 3 or 6 weeks, and the feasibility of separate lung lobes for histopathology or the Comet assay. Rats were exposed to sham air or CS (1 or 2 h) for 3 or 6 weeks. Respiratory tissues were processed for histopathological evaluation, and Alveolar type II cells (AEC II) isolated for the Comet assay. Blood was collected for Pig-a and micronucleus quantification. Histopathological analyses demonstrated exposure effects, which were generally dependent on CS dose (1 or 2 h, 5 days/week). Comet analysis identified that DNA damage increased in AEC II following 3 or 6 weeks CS exposure, and the level at 6 weeks was higher than 3 weeks. Pig-a mutation or micronucleus levels were not increased. In conclusion, this study showed that 3 weeks of CS exposure was sufficient to observe respiratory tract pathology and DNA damage in isolated AEC II. Differences between the 3 and 6 week data imply that DNA damage in the lung is cumulative. Reducing exposure time, plus analyzing separate lung lobes for DNA damage or histopathology, supports a strategy to reduce and refine animal use in tobacco product testing and is aligned to the 3Rs (replacement, reduction and refinement). PMID:27160659

  1. Civil construction work: The unseen contributor to the occupational and global disease burden

    PubMed Central

    Sitalakshmi, R.; Saikumar, P.; Jeyachandran, P.; Manoharan; Thangavel; Thomas, Jayakar

    2016-01-01

    Background: Construction industry is the second largest employment giving industry in India with many semi-skilled or unskilled workers taking up the occupation for livelihood without any training and proper guidance. Aim: To evaluate the pathogenic association of cement exposure to occupational contact dermatoses as evidenced by immune markers and to correlate their pulmonary functions with years of exposure to cement. Setting and Design: This was a cross-sectional study conducted among randomly selected cement workers. Methods and material: Evaluation of socioeconomic status (SES) and years of exposure of cement workers was done using a questionnaire. Clinical examination of skin lesions and strip patch test with application of potassium dichromate on unexposed skin was performed. Results were interpreted after 48 hours. Absolute eosinophil count (AEC) and IgE levels measured, and spirometric evaluation was performed. Statistical Analysis: Analysis of variance and Pearson's correlation test were used for data analysis. P < 0.05 was considered to be statistically significant. Results: Clinically, skin lesions were noticed in 51%, elevated AEC in 47%, and raised Anti IgE in 73%. Two participants developed positive reactions to the skin strip patch test. Duration of exposure to cement and SES were compared with clinical skin lesions. Spirometry result was normal in 81%, obstruction in 8%, restriction in 10%, and mixed pattern in 1%. Forced expiratory volume at 1.0 second, forced expiratory flow (25–75%), and  (PEFR) Peak Expiratory Flow Rate were markedly reduced with years of exposure. Workers who had greater skin lesions and with increase in exposure had increased AEC and IgE levels, although statistically not significant. Conclusions: Exposure to cement and poor SES is strongly correlated to increased prevalence of skin lesions and reduced pulmonary functions. PMID:28194084

  2. Civil construction work: The unseen contributor to the occupational and global disease burden.

    PubMed

    Sitalakshmi, R; Saikumar, P; Jeyachandran, P; Manoharan; Thangavel; Thomas, Jayakar

    2016-01-01

    Construction industry is the second largest employment giving industry in India with many semi-skilled or unskilled workers taking up the occupation for livelihood without any training and proper guidance. To evaluate the pathogenic association of cement exposure to occupational contact dermatoses as evidenced by immune markers and to correlate their pulmonary functions with years of exposure to cement. This was a cross-sectional study conducted among randomly selected cement workers. Methods and material: Evaluation of socioeconomic status (SES) and years of exposure of cement workers was done using a questionnaire. Clinical examination of skin lesions and strip patch test with application of potassium dichromate on unexposed skin was performed. Results were interpreted after 48 hours. Absolute eosinophil count (AEC) and IgE levels measured, and spirometric evaluation was performed. Analysis of variance and Pearson's correlation test were used for data analysis. P < 0.05 was considered to be statistically significant. Clinically, skin lesions were noticed in 51%, elevated AEC in 47%, and raised Anti IgE in 73%. Two participants developed positive reactions to the skin strip patch test. Duration of exposure to cement and SES were compared with clinical skin lesions. Spirometry result was normal in 81%, obstruction in 8%, restriction in 10%, and mixed pattern in 1%. Forced expiratory volume at 1.0 second, forced expiratory flow (25-75%), and  (PEFR) Peak Expiratory Flow Rate were markedly reduced with years of exposure. Workers who had greater skin lesions and with increase in exposure had increased AEC and IgE levels, although statistically not significant. Exposure to cement and poor SES is strongly correlated to increased prevalence of skin lesions and reduced pulmonary functions.

  3. Calcitonin gene-related peptide protects type II alveolar epithelial cells from hyperoxia-induced DNA damage and cell death.

    PubMed

    Fu, Hongmin; Zhang, Tiesong; Huang, Rongwei; Yang, Zhen; Liu, Chunming; Li, Ming; Fang, Fang; Xu, Feng

    2017-04-01

    Hyperoxia therapy for acute lung injury (ALI) may unexpectedly lead to reactive oxygen species (ROS) production and cause additional ALI. Calcitonin gene-related peptide (CGRP) is a 37 amino acid neuropeptide that regulates inflammasome activation. However, the role of CGRP in DNA damage during hyperoxia is unclear. Therefore, the aim of the present study was to investigate the effects of CGRP on DNA damage and the cell death of alveolar epithelial type II cells (AEC II) exposed to 60% oxygen. AEC II were isolated from 19-20 gestational day fetal rat lungs and were exposed to air or to 60% oxygen during treatment with CGRP or the specific CGRP receptor antagonist CGRP 8-37 . The cells were evaluated using immunofluorescence to examine surfactant protein-C and ROS levels were measured by probing with 2',7'-dichlorofluorescin diacetate. The apoptosis rate and cell cycle of AEC II were analyzed by flow cytometry, and apoptosis was determined by western blotting analysis of activated caspase 3. The DNA damage was confirmed with immunofluorescence of H2AX via high-content analysis. The ROS levels, apoptotic cell number and the expression of γH2AX were markedly increased in the hyperoxia group compared with those in the air group. Concordantly, ROS levels, apoptotic cell number and the expression of γH2AX were significantly lower with a significant arrest of S and G2/M phases in the CGRP/O 2 group than in the hyperoxia or CGRP 8-37 /O 2 groups. CGRP was concluded to protect lung epithelium cells against hyperoxic insult, and upregulation of CGRP may be a possible novel therapeutic target to treat hyperoxic lung injury.

  4. Cigarette smoke induced genotoxicity and respiratory tract pathology: evidence to support reduced exposure time and animal numbers in tobacco product testing.

    PubMed

    Dalrymple, Annette; Ordoñez, Patricia; Thorne, David; Walker, David; Camacho, Oscar M; Büttner, Ansgar; Dillon, Debbie; Meredith, Clive

    2016-06-01

    Many laboratories are working to develop in vitro models that will replace in vivo tests, but occasionally there remains a regulatory expectation of some in vivo testing. Historically, cigarettes have been tested in vivo for 90 days. Recently, methods to reduce and refine animal use have been explored. This study investigated the potential of reducing animal cigarette smoke (CS) exposure to 3 or 6 weeks, and the feasibility of separate lung lobes for histopathology or the Comet assay. Rats were exposed to sham air or CS (1 or 2 h) for 3 or 6 weeks. Respiratory tissues were processed for histopathological evaluation, and Alveolar type II cells (AEC II) isolated for the Comet assay. Blood was collected for Pig-a and micronucleus quantification. Histopathological analyses demonstrated exposure effects, which were generally dependent on CS dose (1 or 2 h, 5 days/week). Comet analysis identified that DNA damage increased in AEC II following 3 or 6 weeks CS exposure, and the level at 6 weeks was higher than 3 weeks. Pig-a mutation or micronucleus levels were not increased. In conclusion, this study showed that 3 weeks of CS exposure was sufficient to observe respiratory tract pathology and DNA damage in isolated AEC II. Differences between the 3 and 6 week data imply that DNA damage in the lung is cumulative. Reducing exposure time, plus analyzing separate lung lobes for DNA damage or histopathology, supports a strategy to reduce and refine animal use in tobacco product testing and is aligned to the 3Rs (replacement, reduction and refinement).

  5. Development of a consensus protocol to quantify primate anti-non-Gal xenoreactive antibodies using pig aortic endothelial cells.

    PubMed

    Azimzadeh, Agnes M; Byrne, Guerard W; Ezzelarab, Mohamed; Welty, Emily; Braileanu, Gheorghe; Cheng, Xiangfei; Robson, Simon C; McGregor, Christopher G A; Cooper, David K C; Pierson, Richard N

    2014-01-01

    Scientists working in the field of xenotransplantation do not employ a uniform method to measure and report natural and induced antibody responses to non-Galα(1,3)Gal (non-Gal) epitopes. Such humoral responses are thought to be particularly pathogenic after transplantation of vascularized GalTKO pig organs and having a more uniform assay and reporting format would greatly facilitate comparisons between laboratories. Flow cytometry allows examination of antibody reactivity to intact antigens in their natural location and conformation on cell membranes. We have established a simple and reproducible flow cytometric assay to detect antibodies specific for non-Gal pig antigens using primary porcine aortic endothelial cells (pAECs) and cell culture-adapted pAEC cell lines generated from wild type and α1,3galactosyl transferase knockout (GalTKO) swine. The consensus protocol we propose here is based on procedures routinely used in four xenotransplantation centers and was independently evaluated at three sites using shared cells and serum samples. Our observation support use of the cell culture-adapted GalTKO pAEC KO:15502 cells as a routine method to determine the reactivity of anti-non-Gal antibodies in human and baboon serum. We have developed an assay that allows the detection of natural and induced non-Gal xenoreactive antibodies present in human or baboon serum in a reliable and consistent manner. This consensus assay and format for reporting the data should be accessible to laboratories and will be useful for assessing experimental results between multiple research centers. Adopting this assay and format for reporting the data should facilitate the detection, monitoring, and detailed characterization of non-Gal antibody responses. © 2014 John Wiley & Sons A/S Published by John Wiley & Sons Ltd.

  6. Endogenous minerals have influences on surface electrochemistry and ion exchange properties of biochar.

    PubMed

    Zhao, Ling; Cao, Xinde; Zheng, Wei; Wang, Qun; Yang, Fan

    2015-10-01

    The feedstocks for biochar production are diverse and many of them contain various minerals in addition to being rich in carbon. Twelve types of biomass classified into 2 categories: plant-based and municipal waste, were employed to produce biochars under 350 °C and 500 °C. Their pH, point of zero net charge (PZNC), zeta potential, cation and anion exchange capacity (CEC and AEC) were analyzed. The municipal waste-based biochars (MW-BC) had higher mineral levels than the plant-based biochars (PB-BC). However, the water soluble mineral levels were lower in the MW-BCs due to the dominant presence of less soluble minerals, such as CaCO3 and (Ca,Mg)3(PO4)2. The higher total minerals in MW-BCs accounted for the higher PZNC (5.47-9.95) than in PB-BCs (1.91-8.18), though the PZNCs of the PB-BCs increased more than that of the MW-BCs as the production temperature rose. The minerals had influence on the zeta potentials via affecting the negative charges of biochars and the ionic strength of solution. The organic functional groups in PB-BCs such as -COOH and -OH had a greater effect on the CEC and AEC, while the minerals had a greater effect on that of MW-BCs. The measured CEC and AEC values had a strong positive correlation with the total amount of soluble cations and anions, respectively. Results indicated that biochar surface charges depend not only on the organic functional groups, but also on the minerals present and to some extent, minerals have more influences on the surface electrochemistry and ion exchange properties of biochar. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. REMOVAL OF CESIUM BY SORPTION FROM AQUEOUS SOLUTIONS

    DOEpatents

    Ames, L.L.

    1962-01-16

    ABS>A process is given for selectively removing cesium from acid aqueous solutions containing cesium in microquantities and other cations in macroquantities by absorption on clinoptilolite. The cesium can be eluted from the clinoptilolite with a solution of ammonia, potassium hydroxide, or rubidium hydroxide. (AEC)

  8. Scope of Work for Joint W28/AGM-28A Missile Firing Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bice, R.A.

    1964-12-04

    List of principles & responsibilities of this Sandia/AEC & Air Force joint program for verifying the functionability of the W28/AGM-28A/B-52 weapon system under actual routine handling, assembling, and firing during a stockpile-to-target sequence.

  9. Scope of Work for the Joint W53/Titan II Missile Firing Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1964-10-28

    List of principles & responsibilities of this Sandia/AEC & Air Force joint program for verifying the functionability of the W28/AGM-28A/B-52 weapon system under actual routine handling, assembling, and firing during a stockpile-to-target sequence.

  10. NEUTRONIC REACTOR SHIELDING

    DOEpatents

    Borst, L.B.

    1961-07-11

    A special hydrogenous concrete shielding for reactors is described. In addition to Portland cement and water, the concrete essentially comprises 30 to 60% by weight barytes aggregate for enhanced attenuation of fast neutrons. The biological shields of AEC's Oak Ridge Graphite Reactor and Materials Testing Reactor are particular embodiments.

  11. Fourteenth Semiannual Report of the Commission to the Congress. Major Activities in the Atomic Energy Programs, January - June 1953

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dean, Gordon

    1953-07-31

    The document represents the fourteenth semiannual Atomic Energy Commission (AEC) report to Congress. The report sums up the major activities and developments in the national atomic energy program covering the period January - June 1953.

  12. Aeromedical Evacuation: Validating Civil Reserve Air Fleet

    DTIC Science & Technology

    2009-02-25

    flight nurses and three medical technicians) is added for AE missions. The aeromedical evacuation crew (AEC) may be pared and tailored as required in... Biosecurity and Bioterrorism: Biodefense Strategy, Practice and Science, Volume 5, Number 4, 2007: 319-325. 34 IAT.R 0554 General Accounting Office

  13. PROCESS OF PREPARING URANIUM CARBIDE

    DOEpatents

    Miller, W.E.; Stethers, H.L.; Johnson, T.R.

    1964-03-24

    A process of preparing uranium monocarbide is de scribed. Uranium metal is dissolved in cadmium, zinc, cadmium-- zinc, or magnesium-- zinc alloy and a small quantity of alkali metal is added. Addition of stoichiometric amounts of carbon at 500 to 820 deg C then precipitates uranium monocarbide. (AEC)

  14. METHOD OF BRAZING BERYLLIUM

    DOEpatents

    Hanks, G.S.; Keil, R.W.

    1963-05-21

    A process is described for brazing beryllium metal parts by coating the beryllium with silver (65- 75 wt%)-aluminum alloy using a lithium fluoride (50 wt%)-lithium chloride flux, and heating the coated joint to a temperature of about 700 un. Concent 85% C for about 10 minutes. (AEC)

  15. Assessing students' sentiments towards the use of a Building Information Modelling (BIM) learning platform in a construction project management course

    NASA Astrophysics Data System (ADS)

    Suwal, Sunil; Singh, Vishal

    2018-07-01

    Building Information Modelling (BIM) tools and processes are increasingly adopted and implemented in the construction industry. Consequently, BIM education is considered increasingly important in Architecture, Engineering and Construction (AEC) education. While most of the research and literature on BIM education in engineering studies has focused on BIM implementation strategies, processes, benefits, and challenges, there is limited study on students' perception towards the implementation of BIM courses, or about online BIM learning platforms, or about the BIM tools themselves. Therefore, this paper takes the first steps towards addressing this gap. This study analyses students' (57 students) perception and sentiments towards the use of an online BIM learning platform and explores the potential implications of the findings for BIM education. The findings suggest that online BIM learning platforms are highly rated by students as a positive learning experience, indicating the need for greater integration of such tools and approaches in AEC courses.

  16. Observations of field-aligned currents, particles, and plasma drift in the polar cusps near solstice

    NASA Technical Reports Server (NTRS)

    Bythrow, P. F.; Potemra, T. A.; Hoffman, R. A.

    1982-01-01

    Magnetic perturbations observed by the TRIAD magnetometer within two hours of an AE-C spacecraft pass provide field-aligned current data, from the same local time in the northern hemisphere, for a study of the polar cusp. The AE-C spinning mode has allowed the use of the Z-axis magnetometer for Birkeland current observations, in conjunction with particle and drift measurements. The average B(z) were found to be 1.9 nT and -1.1 nT during the first two hourly intervals on January 15, 1977. Measurements from the low energy electron experiment revealed intense fluxes of soft, cusp-like 100 eV Maxwellian electrons throughout the prenoon polar cap. The upward directed current can be identified as the dominant cusp current appropriate for B(y) values lower than zero, while the downward directed current, which has the appropriate sign of a dayside region 1 current, is observed to lie entirely within a westerly, antisunward-convecting plasma.

  17. Generation of Alveolar Epithelial Spheroids via Isolated Progenitor Cells from Human Pluripotent Stem Cells

    PubMed Central

    Gotoh, Shimpei; Ito, Isao; Nagasaki, Tadao; Yamamoto, Yuki; Konishi, Satoshi; Korogi, Yohei; Matsumoto, Hisako; Muro, Shigeo; Hirai, Toyohiro; Funato, Michinori; Mae, Shin-Ichi; Toyoda, Taro; Sato-Otsubo, Aiko; Ogawa, Seishi; Osafune, Kenji; Mishima, Michiaki

    2014-01-01

    Summary No methods for isolating induced alveolar epithelial progenitor cells (AEPCs) from human embryonic stem cells (hESCs) and induced pluripotent stem cells (hiPSCs) have been reported. Based on a study of the stepwise induction of alveolar epithelial cells (AECs), we identified carboxypeptidase M (CPM) as a surface marker of NKX2-1+ “ventralized” anterior foregut endoderm cells (VAFECs) in vitro and in fetal human and murine lungs. Using SFTPC-GFP reporter hPSCs and a 3D coculture system with fetal human lung fibroblasts, we showed that CPM+ cells isolated from VAFECs differentiate into AECs, demonstrating that CPM is a marker of AEPCs. Moreover, 3D coculture differentiation of CPM+ cells formed spheroids with lamellar-body-like structures and an increased expression of surfactant proteins compared with 2D differentiation. Methods to induce and isolate AEPCs using CPM and consequently generate alveolar epithelial spheroids would aid human pulmonary disease modeling and regenerative medicine. PMID:25241738

  18. Fusion Studies in Japan

    NASA Astrophysics Data System (ADS)

    Ogawa, Yuichi

    2016-05-01

    A new strategic energy plan decided by the Japanese Cabinet in 2014 strongly supports the steady promotion of nuclear fusion development activities, including the ITER project and the Broader Approach activities from the long-term viewpoint. Atomic Energy Commission (AEC) in Japan formulated the Third Phase Basic Program so as to promote an experimental fusion reactor project. In 2005 AEC has reviewed this Program, and discussed on selection and concentration among many projects of fusion reactor development. In addition to the promotion of ITER project, advanced tokamak research by JT-60SA, helical plasma experiment by LHD, FIREX project in laser fusion research and fusion engineering by IFMIF were highly prioritized. Although the basic concept is quite different between tokamak, helical and laser fusion researches, there exist a lot of common features such as plasma physics on 3-D magnetic geometry, high power heat load on plasma facing component and so on. Therefore, a synergetic scenario on fusion reactor development among various plasma confinement concepts would be important.

  19. Stereoscopic applications for design visualization

    NASA Astrophysics Data System (ADS)

    Gilson, Kevin J.

    2007-02-01

    Advances in display technology and 3D design visualization applications have made real-time stereoscopic visualization of architectural and engineering projects a reality. Parsons Brinkerhoff (PB) is a transportation consulting firm that has used digital visualization tools from their inception and has helped pioneer the application of those tools to large scale infrastructure projects. PB is one of the first Architecture/Engineering/Construction (AEC) firms to implement a CAVE- an immersive presentation environment that includes stereoscopic rear-projection capability. The firm also employs a portable stereoscopic front-projection system, and shutter-glass systems for smaller groups. PB is using commercial real-time 3D applications in combination with traditional 3D modeling programs to visualize and present large AEC projects to planners, clients and decision makers in stereo. These presentations create more immersive and spatially realistic presentations of the proposed designs. This paper will present the basic display tools and applications, and the 3D modeling techniques PB is using to produce interactive stereoscopic content. The paper will discuss several architectural and engineering design visualizations we have produced.

  20. Human radiation studies: Remembering the early years. Oral history of biochemist John Randolph Totter, Ph.D., January 23, 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-09-01

    This document is a transcript of an interview of Dr. John Randolph Tottler by representatives of the US DOE Office of Human Radiation Experiments. Dr. Tottler was selected for this interview because of his career with the Atomic Energy Commission Division of Biology and Medicine (DBM), particularly as its director from 1967 to 1972. After a short biographical sketch Dr. Tottler discusses his remembrances on a wide range topics including nucleic acid and leukemia research at Oak Ridge, AEC biochemistry training in South America, DBM`s research focus on radiation effects, early leadership of DBM, relations with the US Public Healthmore » Service, controversies on low-level radiation, iodine from fallout, on John Gofman, and Project Plowshare, funding for AEC Research Programs and for international research, testicular irradiation of prisoners in Washington State and Oregon, Plutonium injections, ethics of government radiation research, and opinions of public misperceptions about radiation and cancer.« less

  1. Recruited Monocytes and Type 2 Immunity Promote Lung Regeneration following Pneumonectomy.

    PubMed

    Lechner, Andrew J; Driver, Ian H; Lee, Jinwoo; Conroy, Carmen M; Nagle, Abigail; Locksley, Richard M; Rock, Jason R

    2017-07-06

    To investigate the role of immune cells in lung regeneration, we used a unilateral pneumonectomy model that promotes the formation of new alveoli in the remaining lobes. Immunofluorescence and single-cell RNA sequencing found CD115+ and CCR2+ monocytes and M2-like macrophages accumulating in the lung during the peak of type 2 alveolar epithelial stem cell (AEC2) proliferation. Genetic loss of function in mice and adoptive transfer studies revealed that bone marrow-derived macrophages (BMDMs) traffic to the lung through a CCL2-CCR2 chemokine axis and are required for optimal lung regeneration, along with Il4ra-expressing leukocytes. Our data suggest that these cells modulate AEC2 proliferation and differentiation. Finally, we provide evidence that group 2 innate lymphoid cells are a source of IL-13, which promotes lung regeneration. Together, our data highlight the potential for immunomodulatory therapies to stimulate alveologenesis in adults. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Autonomous micro and nano sensors for upstream oil and gas

    NASA Astrophysics Data System (ADS)

    Chapman, David; Trybula, Walt

    2015-06-01

    This paper describes the development of autonomous electronic micro and nanoscale sensor systems for very harsh downhole oilfield conditions and provides an overview of the operational requirements necessary to survive and make direct measurements of subsurface conditions. One of several significant developmental challenges is selecting appropriate technologies that are simultaneously miniaturize-able, integrate-able, harsh environment capable, and economically viable. The Advanced Energy Consortium (AEC) is employing a platform approach to developing and testing multi-chip, millimeter and micron-scale systems in a package at elevated temperature and pressure in API brine and oil analogs, with the future goal of miniaturized systems that enable the collection of previously unattainable data. The ultimate goal is to develop subsurface nanosensor systems that can be injected into oil and gas well bores, to gather and record data, providing an unparalleled level of direct reservoir characterization. This paper provides a status update on the research efforts and developmental successes at the AEC.

  3. Researcher Poses with a Nuclear Rocket Model

    NASA Image and Video Library

    1961-11-21

    A researcher at the NASA Lewis Research Center with slide ruler poses with models of the earth and a nuclear-propelled rocket. The Nuclear Engine for Rocket Vehicle Applications (NERVA) was a joint NASA and Atomic Energy Commission (AEC) endeavor to develop a nuclear-powered rocket for both long-range missions to Mars and as a possible upper-stage for the Apollo Program. The early portion of the program consisted of basic reactor and fuel system research. This was followed by a series of Kiwi reactors built to test nuclear rocket principles in a non-flying nuclear engine. The next phase, NERVA, would create an entire flyable engine. The AEC was responsible for designing the nuclear reactor and overall engine. NASA Lewis was responsible for developing the liquid-hydrogen fuel system. The nuclear rocket model in this photograph includes a reactor at the far right with a hydrogen propellant tank and large radiator below. The payload or crew would be at the far left, distanced from the reactor.

  4. Design of a Low-Power, Small-Area AEC-Q100-Compliant SENT Transmitter in Signal Conditioning IC for Automotive Pressure and Temperature Complex Sensors in 180 Nm CMOS Technology.

    PubMed

    Ali, Imran; Rikhan, Behnam Samadpoor; Kim, Dong-Gyu; Lee, Dong-Soo; Rehman, Muhammad Riaz Ur; Abbasizadeh, Hamed; Asif, Muhammad; Lee, Minjae; Hwang, Keum Cheol; Yang, Youngoo; Lee, Kang-Yoon

    2018-05-14

    In this paper, a low-power and small-area Single Edge Nibble Transmission (SENT) transmitter design is proposed for automotive pressure and temperature complex sensor applications. To reduce the cost and size of the hardware, the pressure and temperature information is processed with a single integrated circuit (IC) and transmitted at the same time to the electronic control unit (ECU) through SENT. Due to its digital nature, it is immune to noise, has reduced sensitivity to electromagnetic interference (EMI), and generates low EMI. It requires only one PAD for its connectivity with ECU, and thus reduces the pin requirements, simplifies the connectivity, and minimizes the printed circuit board (PCB) complexity. The design is fully synthesizable, and independent of technology. The finite state machine-based approach is employed for area efficient implementation, and to translate the proposed architecture into hardware. The IC is fabricated in 1P6M 180 nm CMOS process with an area of (116 μm × 116 μm) and 4.314 K gates. The current consumption is 50 μA from a 1.8 V supply with a total 90 μW power. For compliance with AEC-Q100 for automotive reliability, a reverse and over voltage protection circuit is also implemented with human body model (HBM) electro-static discharge (ESD) of +6 kV, reverse voltage of -16 V to 0 V, over voltage of 8.2 V to 16 V, and fabricated area of 330 μm × 680 μm. The extensive testing, measurement, and simulation results prove that the design is fully compliant with SAE J2716 standard.

  5. Design of a Low-Power, Small-Area AEC-Q100-Compliant SENT Transmitter in Signal Conditioning IC for Automotive Pressure and Temperature Complex Sensors in 180 Nm CMOS Technology

    PubMed Central

    Rikhan, Behnam Samadpoor; Kim, Dong-Gyu; Lee, Dong-Soo; Rehman, Muhammad Riaz Ur; Abbasizadeh, Hamed; Asif, Muhammad; Lee, Minjae; Yang, Youngoo; Lee, Kang-Yoon

    2018-01-01

    In this paper, a low-power and small-area Single Edge Nibble Transmission (SENT) transmitter design is proposed for automotive pressure and temperature complex sensor applications. To reduce the cost and size of the hardware, the pressure and temperature information is processed with a single integrated circuit (IC) and transmitted at the same time to the electronic control unit (ECU) through SENT. Due to its digital nature, it is immune to noise, has reduced sensitivity to electromagnetic interference (EMI), and generates low EMI. It requires only one PAD for its connectivity with ECU, and thus reduces the pin requirements, simplifies the connectivity, and minimizes the printed circuit board (PCB) complexity. The design is fully synthesizable, and independent of technology. The finite state machine-based approach is employed for area efficient implementation, and to translate the proposed architecture into hardware. The IC is fabricated in 1P6M 180 nm CMOS process with an area of (116 μm × 116 μm) and 4.314 K gates. The current consumption is 50 μA from a 1.8 V supply with a total 90 μW power. For compliance with AEC-Q100 for automotive reliability, a reverse and over voltage protection circuit is also implemented with human body model (HBM) electro-static discharge (ESD) of +6 kV, reverse voltage of −16 V to 0 V, over voltage of 8.2 V to 16 V, and fabricated area of 330 μm × 680 μm. The extensive testing, measurement, and simulation results prove that the design is fully compliant with SAE J2716 standard. PMID:29757996

  6. Digital mammography--DQE versus optimized image quality in clinical environment: an on site study

    NASA Astrophysics Data System (ADS)

    Oberhofer, Nadia; Fracchetti, Alessandro; Springeth, Margareth; Moroder, Ehrenfried

    2010-04-01

    The intrinsic quality of the detection system of 7 different digital mammography units (5 direct radiography DR; 2 computed radiography CR), expressed by DQE, has been compared with their image quality/dose performances in clinical use. DQE measurements followed IEC 62220-1-2 using a tungsten test object for MTF determination. For image quality assessment two different methods have been applied: 1) measurement of contrast to noise ratio (CNR) according to the European guidelines and 2) contrast-detail (CD) evaluation. The latter was carried out with the phantom CDMAM ver. 3.4 and the commercial software CDMAM Analyser ver. 1.1 (both Artinis) for automated image analysis. The overall image quality index IQFinv proposed by the software has been validated. Correspondence between the two methods has been shown figuring out a linear correlation between CNR and IQFinv. All systems were optimized with respect to image quality and average glandular dose (AGD) within the constraints of automatic exposure control (AEC). For each equipment, a good image quality level was defined by means of CD analysis, and the corresponding CNR value considered as target value. The goal was to achieve for different PMMA-phantom thicknesses constant image quality, that means the CNR target value, at minimum dose. All DR systems exhibited higher DQE and significantly better image quality compared to CR systems. Generally switching, where available, to a target/filter combination with an x-ray spectrum of higher mean energy permitted dose savings at equal image quality. However, several systems did not allow to modify the AEC in order to apply optimal radiographic technique in clinical use. The best ratio image quality/dose was achieved by a unit with a-Se detector and W anode only recently available on the market.

  7. IgA and IgM protein primarily drive plasma corona‐induced adhesion reduction of PLGA nanoparticles in human blood flow

    PubMed Central

    Sobczynski, Daniel J.

    2017-01-01

    Abstract The high abundance of immunoglobulins (Igs) in the plasma protein corona on poly(lactic‐co‐glycolic) acid (PLGA)‐based vascular‐targeted carriers (VTCs) has previously been shown to reduce their adhesion to activated endothelial cells (aECs) in human blood flow. However, the relative role of individual Ig classes (e.g., IgG, IgA, and IgM) in causing adhesion reduction remains largely unknown. Here, we characterized the influence of specific Ig classes in prescribing the binding efficiency of PLGA nano‐sized VTCs in blood flow. Specifically, we evaluated the flow adhesion to aECs of PLGA VTCs with systematic depletion of various Igs in their corona. Adhesion reduction was largely eliminated for PLGA VTCs when all Igs were removed from the corona. Furthermore, re‐addition of IgA or IgM to the Igs‐depleted corona reinstated the low adhesion of PLGA VTCs, as evidenced by ∼40–70% reduction relative to particles with an Igs‐deficient corona. However, re‐addition of a high concentration of IgG to the Igs‐depleted corona did not cause significant adhesion reduction. Overall, the presented results reveal that PLGA VTC adhesion reduction in blood flows is primarily driven by high adsorption of IgA and IgM in the particle corona. Pre‐coating of albumin on PLGA VTCs mitigated the extent of adhesion reduction in plasma for some donors but was largely ineffective in general. Overall, this work may shed light into effective control of protein corona composition, thereby enhancing VTC functionality in vivo for eventual clinical use. PMID:28932819

  8. Anatomy-based transmission factors for technique optimization in portable chest x-ray

    NASA Astrophysics Data System (ADS)

    Liptak, Christopher L.; Tovey, Deborah; Segars, William P.; Dong, Frank D.; Li, Xiang

    2015-03-01

    Portable x-ray examinations often account for a large percentage of all radiographic examinations. Currently, portable examinations do not employ automatic exposure control (AEC). To aid in the design of a size-specific technique chart, acrylic slabs of various thicknesses are often used to estimate x-ray transmission for patients of various body thicknesses. This approach, while simple, does not account for patient anatomy, tissue heterogeneity, and the attenuation properties of the human body. To better account for these factors, in this work, we determined x-ray transmission factors using computational patient models that are anatomically realistic. A Monte Carlo program was developed to model a portable x-ray system. Detailed modeling was done of the x-ray spectrum, detector positioning, collimation, and source-to-detector distance. Simulations were performed using 18 computational patient models from the extended cardiac-torso (XCAT) family (9 males, 9 females; age range: 2-58 years; weight range: 12-117 kg). The ratio of air kerma at the detector with and without a patient model was calculated as the transmission factor. Our study showed that the transmission factor decreased exponentially with increasing patient thickness. For the range of patient thicknesses examined (12-28 cm), the transmission factor ranged from approximately 21% to 1.9% when the air kerma used in the calculation represented an average over the entire imaging field of view. The transmission factor ranged from approximately 21% to 3.6% when the air kerma used in the calculation represented the average signals from two discrete AEC cells behind the lung fields. These exponential relationships may be used to optimize imaging techniques for patients of various body thicknesses to aid in the design of clinical technique charts.

  9. Accounting for patient size in the optimization of dose and image quality of pelvis cone beam CT protocols on the Varian OBI system

    PubMed Central

    Moore, Craig S; Horsfield, Carl J; Saunderson, John R; Beavis, Andrew W

    2015-01-01

    Objective: The purpose of this study was to develop size-based radiotherapy kilovoltage cone beam CT (CBCT) protocols for the pelvis. Methods: Image noise was measured in an elliptical phantom of varying size for a range of exposure factors. Based on a previously defined “small pelvis” reference patient and CBCT protocol, appropriate exposure factors for small, medium, large and extra-large patients were derived which approximate the image noise behaviour observed on a Philips CT scanner (Philips Medical Systems, Best, Netherlands) with automatic exposure control (AEC). Selection criteria, based on maximum tube current–time product per rotation selected during the radiotherapy treatment planning scan, were derived based on an audit of patient size. Results: It has been demonstrated that 110 kVp yields acceptable image noise for reduced patient dose in pelvic CBCT scans of small, medium and large patients, when compared with manufacturer's default settings (125 kVp). Conversely, extra-large patients require increased exposure factors to give acceptable images. 57% of patients in the local population now receive much lower radiation doses, whereas 13% require higher doses (but now yield acceptable images). Conclusion: The implementation of size-based exposure protocols has significantly reduced radiation dose to the majority of patients with no negative impact on image quality. Increased doses are required on the largest patients to give adequate image quality. Advances in knowledge: The development of size-based CBCT protocols that use the planning CT scan (with AEC) to determine which protocol is appropriate ensures adequate image quality whilst minimizing patient radiation dose. PMID:26419892

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCone, John A.

    The document represents the first annual reporting versus semiannual reporting of the Atomic Energy Commission (AEC) to Congress. The report consists of three parts: Part One, The Atomic Energy Industry in 1959 and Related Activities; Part Two, Major Activities in Atomic Energy Programs; and Part Three, Management of Radioactive Wastes. Nineteen appendices are also included.

  11. Scope of Work for the Joint Mk 38 Warhead/Atlas F Missile Firing Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1964-11-16

    List of principles & responsibilities of this Sandia/AEC & Air Force joint program for verifying the functionability of the W28/AGM-28A/B-52 weapon system under actual routine handling, assembling, and firing during a stockpile-to-target sequence.

  12. Scope of Work for Joint W28/AGM-28A Missile Firing Program (Phase 1)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Draper, E.H.

    1965-04-16

    List of principles & responsibilities of this Sandia/AEC & Air Force joint program for verifying the functionability of the W28/AGM-28A/B-52 weapon system under actual routine handling, assembling, and firing during a stockpile-to-target sequence.

  13. Scope of Work for Mk 28 FI Bomb and B52 Drop Test Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Draper, E.H.

    1965-10-04

    List of principles & responsibilities of this Sandia/AEC & Air Force joint program for verifying the functionability of the W28/AGM-28A/B-52 weapon system under actual routine handling, assembling, and firing during a stockpile-to-target sequence.

  14. METHOD OF PREPARING A FUEL ELEMENT FOR A NUCLEAR REACTOR

    DOEpatents

    Hauth, J.J.; Anicetti, R.J.

    1962-12-01

    A method is described for preparing a fuel element for a nuclear reactor. According to the patent uranium dioxide is compacted in a metal tabe by directlng intense sound waves at the tabe prior to tamp packing or vibration compaction of the powder. (AEC)

  15. VIBRATION COMPACTION

    DOEpatents

    Hauth, J.J.

    1962-07-01

    A method of compacting a powder in a metal container is described including the steps of vibrating the container at above and below the resonant frequency and also sweeping the frequency of vibration across the resonant frequency several times thereby following the change in resonant frequency caused by compaction of the powder. (AEC)

  16. Teaching Information Retrieval Using Telediscussion Techniques.

    ERIC Educational Resources Information Center

    Heiliger, Edward M.

    This paper concerns an experiment in teaching a graduate seminar on Information Retrieval using telediscussion techniques. Outstanding persons from Project INTREX, MEDLARS, Chemical Abstracts, the University of Georgia, the SUNY biomedical Network, AEC, NASA, and DDC gave hour-long telelectures. A Conference Telephone Set was used with success.…

  17. METHOD OF USING AND MANUFACTURING PLASTIC EQUIVALENT TO ORGANIC MATERIALS

    DOEpatents

    Shonka, F.R.; Rose, J.E.; Failla, G.

    1961-10-24

    Compositions of matter that have the radiation response of animal muscle tissue, bone, or air were prepared. These compositions are composed of specific proportions of three or more of the following constituents: polyethylene plastic, polyamide plastic, oil furnace black, silica, and calcium fluoride. (AEC)

  18. NON-CORROSIVE REACTOR FUEL SYSTEM

    DOEpatents

    Herrick, C.C.

    1962-08-14

    A non-corrosive nuclear reactor fuel system was developed utilizing a molten plutonium-- iron alloy fuel having about 2 at.% carbon and contained in a tantalum vessel. This carbon reacts with the interior surface of the tantalum vessel to form a plutonium resistant self-healing tantalum carbide film. (AEC)

  19. ADSORPTION OF CERIUM VALUES FROM AQUEOUS SOLUTIONS

    DOEpatents

    Roberts, F.P.

    1963-08-13

    Cerium can be removed from aqueous nitric acid (2 to 13 M) solutions by passing the latter over a PbO/sub 2/-containing anion exchange resin. The cerium is taken up by the resin, while any lanthanides, yttrium, and strontium present remain in the solution. (AEC)

  20. FOIL ELEMENT FOR NUCLEAR REACTOR

    DOEpatents

    Noland, R.A.; Walker, D.E.; Spinrad, B.I.

    1963-07-16

    A method of making a foil-type fuel element is described. A foil of fuel metal is perforated in; regular design and sheets of cladding metal are placed on both sides. The cladding metal sheets are then spot-welded to each other through the perforations, and the edges sealed. (AEC)

  1. GOLD PRESSURE VESSEL SEAL

    DOEpatents

    Smith, A.E.

    1963-11-26

    An improved seal between the piston and die member of a piston-cylinder type pressure vessel is presented. A layer of gold, of sufficient thickness to provide an interference fit between the piston and die member, is plated on the contacting surface of at least one of the members. (AEC)

  2. METHOD OF OPERATING A NEUTRONIC REACTOR

    DOEpatents

    Turkevich, A.

    1963-01-22

    This patent relates to one step in a method of operating a neutronic reactor consisting of a slurry of fissionable material in heavy water. Deuterium gas is passed through the slurry to sweep gaseous fission products therefrom and the deuterium is then separated from the gaseous fission products. (AEC)

  3. Immunotoxicity and genotoxicity testing for in-flight experiments under microgravity

    NASA Astrophysics Data System (ADS)

    Hansen, Peter-Diedrich; Hansen, Peter-Diedrich; Unruh, Eckehardt

    Life Sciences as Related to Space (F) Influence of Spaceflight Environment on Biological Systems (F44) Immunotoxicity and genotoxicity testing for In-flight experiments under microgravity Sensing approaches for ecosystem and human health Author: Peter D. Hansen Technische Universit¨t Berlin, Faculty VI - Planen, Bauen, Umwelt, a Institute for Ecological Research and Technology, Department for Ecotoxicology, Berlin, Germany Peter-diedrich.hansen@tu-berlin.de Eckehardt Unruh Technische Universit¨t Berlin, Faculty VI - Planen, Bauen, Umwelt, Institute a for Ecological Research and Technology, Department for Ecotoxicology, Berlin, Germany An immune response by mussel hemocytes is the selective reaction to particles which are identified as foreign by its immune system shown by phagocytosis. Phagocytotic activity is based on the chemotaxis and adhesion, ingestion and phagosome formation. The attachment at the surface of the hemocytes and consequently the uptake of the particles or bacteria can be directly quantified in the format of a fluorescent assay. Another relevant endpoint of phagocytosis is oxidative burst measured by luminescence. Phagocytosis-related production of ROS will be stimulated with opsonised zymosan. The hemocytes will be stored frozen at -80oC and reconstituted in-flight for the experiment. The assay system of the TRIPLELUX-B Experiment has been performed with a well-defined quantification and evaluation of the immune function phagocytosis. The indicator cells are the hemocytes of blue mussels (Mytilus edulis). The signals of the immuno cellular responses are translated into luminescence as a rapid optical reporter system. The results expected will determine whether the observed responses are caused by microgravity and/or radiation (change in permeability, endpoints in genotoxicity: DNA unwinding). The samples for genotoxicity will be processed after returning to earth. The immune system of invertebrates has not been studied so far in space. The choice of phagocytes from invertebrates is justified to study the universal validity of innate immune responses. The TRIPLELUX-B Experiment contributes to risk assessment concerning immunotoxicity under space flight conditions. The components of the phagocytosis test system for the BIOLAB are now established and the technical realization of the TRIPLELUX- B Experiment is in final progess. The components of the fully automated AEC (Advanced Experimental Containment) will be demonstrated in the poster. There will be two AECs for reference measurements at 1xg and 0xg. The AEC of the TRIPLELUX-B experiment will contribute to a real time operational monitoring for immunotoxicity testing on earth. The AEC will allow "real time monitoring" providing automated observations of immunotoxicity in coastal and inland waters.

  4. METHOD AND APPARATUS FOR DETERMINING AMALGAM DECOMPOSITION RATE

    DOEpatents

    Johnson, R.W.; Wright, C.C.

    1962-04-24

    A method and apparatus for measuring the rate at which an amalgam decomposes in contact with aqueous solutions are described. The amalgam and an aqueous hydroxide solution are disposed in an electrolytic cell. The amalgam is used as the cathode of the cell, and an electrode and anode are disposed in the aqueous solution. A variable source of plating potential is connected across the cell. The difference in voltage between the amalgam cathode and a calibrated source of reference potential is used to control the variable source to null the difference in voltage and at the same time to maintain the concentration of the amalgam at some predetermined constant value. The value of the current required to maintain this concentration constant is indicative of the decomposition rate of the amalgam. (AEC)

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seaborg, Glenn T.

    The document represents the 1961 Annual Report of the Atomic Energy Commission (AEC) to Congress. This year's report consists of four parts: Part One, The Atomic Energy Industry for 1961 and Related Activities; Part Two, Nuclear Power Programs for 1961; Part Three, Major Activities in Atomic Energy Programs; and Part Four, Regulatory Activities. Sixteen appendices are also included.

  6. AIR RADIOACTIVITY MONITOR

    DOEpatents

    Bradshaw, R.L.; Thomas, J.W.

    1961-04-11

    The monitor is designed to minimize undesirable background buildup. It consists of an elongated column containing peripheral electrodes in a central portion of the column, and conduits directing an axial flow of radioactively contaminated air through the center of the column and pure air through the annular portion of the column about the electrodes. (AEC)

  7. THE RECOVERY OF URANIUM FROM GAS MIXTURE

    DOEpatents

    Jury, S.H.

    1964-03-17

    A method of separating uranium from a mixture of uranium hexafluoride and other gases is described that comprises bringing the mixture into contact with anhydrous calcium sulfate to preferentially absorb the uranium hexafluoride on the sulfate. The calcium sulfate is then leached with a selective solvent for the adsorbed uranium. (AEC)

  8. FAST NEUTRON SPECTROMETER USING SPACED SEMICONDUCTORS FOR MEASURING TOTAL ENERGY OF NEUTRONS CAPTURED

    DOEpatents

    Love, T.A.; Murray, R.B.

    1964-04-14

    A fast neutron spectrometer was designed, which utilizes a pair of opposed detectors having a layer of /sup 6/LiF between to produce alpha and T pair for each neutron captured to provide signals, which, when combined, constitute a measure of neutron energy. (AEC)

  9. Through Other Eyes.

    ERIC Educational Resources Information Center

    Education Commission of the States, Denver, CO.

    An international perspective is the new reality for all U.S. interests, including education, and it was on the basis of this belief that the Education Commission of the States (ECS) held the joint conference with the Australian Education Council (AEC) reported in this document. An initial section called "Points to Ponder" raises…

  10. Recovery of Plutonium by Carrier Precipitation

    DOEpatents

    Goeckermann, R. H.

    1961-04-01

    The recovery of plutonium from an aqueous nitric acid Zr-containing solution of 0.2 to 1N acidity is accomplished by adding fluoride anions (1.5 to 5 mg/l), and precipitating the Pu with an excess of H/sub 2/0/sub 2/ at 53 to 65 deg C. (AEC)

  11. METHOD FOR OBTAINING PLUTONIUM METAL FROM ITS TRICHLORIDE

    DOEpatents

    Reavis, J.G.; Leary, J.A.; Maraman, W.J.

    1962-08-14

    A method was developed for obtaining plutonium metal by direct reduction of plutonium chloride, without the use of a booster, using calcium and lanthamum as a reductant, the said reduction being carried out at temperature in the range of 700 to 850 deg C and at about atmospheric pressure. (AEC)

  12. ERYTHROPOIETIC FACTOR PURIFICATION

    DOEpatents

    White, W.F.; Schlueter, R.J.

    1962-05-01

    A method is given for purifying and concentrating the blood plasma erythropoietic factor. Anemic sheep plasma is contacted three times successively with ion exchange resins: an anion exchange resin, a cation exchange resin at a pH of about 5, and a cation exchange resin at a pH of about 6. (AEC)

  13. Eleventh Semiannual Report of the Commission to the Congress, January 1952

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dean, Gordon

    1952-01-31

    The document represents the eleventh semiannual Atomic Energy Commission (AEC) report to Congress. The report sums up the major activities and developments in the national atomic energy program covering the period July - December 1951. Part II covers financial aspects and Part III, Applications in Plant Science.

  14. An Analysis of 27 Years of Research into Computer Education Published in Australian Educational Computing

    ERIC Educational Resources Information Center

    Zagami, Jason

    2015-01-01

    Analysis of three decades of publications in Australian Educational Computing (AEC) provides insight into the historical trends in Australian educational computing, highlighting an emphasis on pedagogy, comparatively few articles on educational technologies, and strong research topic alignment with similar international journals. Analysis confirms…

  15. [Beginnings of bariatric and metabolic surgery in Spain].

    PubMed

    Baltasar, Aniceto; Domínguez-Adame, Eduardo

    2013-01-01

    When bariatric and metabolic surgery initially began in Spain, it was a subject of debate, due to not knowing exactly who were the first surgeons to perform it. A study has revealed the authors of the first interventions. Copyright © 2012 AEC. Published by Elsevier Espana. All rights reserved.

  16. 77 FR 74548 - North Shore Railroad Company-Acquisition and Operation Exemption-PPL Susquehanna, LLC

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-14

    ... Railroad Company--Acquisition and Operation Exemption--PPL Susquehanna, LLC North Shore Railroad Company...., that PPL Susquehanna, LLC (PPLS), and Allegheny Electric Cooperative, Inc. (AEC), the owners of the... extends to an interchange with Norfolk Southern Railway. North Shore states that it provides the only...

  17. PREPARATION OF URANIUM-ALUMINUM ALLOYS

    DOEpatents

    Moore, R.H.

    1962-09-01

    A process is given for preparing uranium--aluminum alloys from a solution of uranium halide in an about equimolar molten alkali metal halide-- aluminum halide mixture and excess aluminum. The uranium halide is reduced and the uranium is alloyed with the excess aluminum. The alloy and salt are separated from each other. (AEC)

  18. Detailed test objectives for the extended long tank delta launch vehicle, spacecraft: AE-C

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The test objectives for the extended long tank Delta Launch Vehicle are presented. The subjects discussed are: (1) mission and vehicle objectives, (2) nominal flight plan, (3) trajectory analysis, (4) weight summary and inflight mass properties, and (5) instrumentation channel assignments and ground monitoring assignments.

  19. Instrumental and Vocal Teacher Education: Competences, Roles and Curricula

    ERIC Educational Resources Information Center

    Lennon, Mary; Reed, Geoffrey

    2012-01-01

    This article focuses on selected outcomes of the European Association of Conservatoires (AEC) "Polifonia" Working Group for Instrumental and Vocal Teacher Training in Europe (2007-2010). The introduction provides the background to the project, explains the rationale and objectives, describes the research process and gives an overview of…

  20. REACTOR FUEL ELEMENTS TESTING CONTAINER

    DOEpatents

    Whitham, G.K.; Smith, R.R.

    1963-01-15

    This patent shows a method for detecting leaks in jacketed fuel elements. The element is placed in a sealed tank within a nuclear reactor, and, while the reactor operates, the element is sparged with gas. The gas is then led outside the reactor and monitored for radioactive Xe or Kr. (AEC)

Top