Multi-axis control based on movement control cards in NC systems
NASA Astrophysics Data System (ADS)
Jiang, Tingbiao; Wei, Yunquan
2005-12-01
Today most movement control cards need special control software of topper computers and are only suitable for fixed-axis controls. Consequently, the number of axes which can be controlled is limited. Advanced manufacture technology develops at a very high speed, and that development brings forth. New requirements for movement control in mechanisms and electronics. This paper introduces products of the 5th generation of movement control cards, PMAC 2A-PC/104, made by the Delta Tau Company in the USA. Based on an analysis of PMAC 2A-PC/104, this paper first describes two aspects relevant to the hardware structure of movement control cards and the interrelated software of the topper computers. Then, two methods are presented for solving these problems. The first method is to set limit switches on the movement control cards; all of them can be used to control each moving axis. The second method is to program applied software with existing programming language (for example, VC ++, Visual Basic, Delphi, and so forth). This program is much easier to operate and expand by its users. By using a limit switch, users can choose different axes in movement control cards. Also, users can change parts of the parameters in the control software of topper computers to realize different control axes. Combining these 2 methods proves to be convenient for realizing multi-axis control in numerical control systems.
Quantum key distribution using card, base station and trusted authority
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nordholt, Jane E.; Hughes, Richard John; Newell, Raymond Thorson
Techniques and tools for quantum key distribution ("QKD") between a quantum communication ("QC") card, base station and trusted authority are described herein. In example implementations, a QC card contains a miniaturized QC transmitter and couples with a base station. The base station provides a network connection with the trusted authority and can also provide electric power to the QC card. When coupled to the base station, after authentication by the trusted authority, the QC card acquires keys through QKD with a trust authority. The keys can be used to set up secure communication, for authentication, for access control, or formore » other purposes. The QC card can be implemented as part of a smart phone or other mobile computing device, or the QC card can be used as a fillgun for distribution of the keys.« less
Quantum key distribution using card, base station and trusted authority
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nordholt, Jane Elizabeth; Hughes, Richard John; Newell, Raymond Thorson
Techniques and tools for quantum key distribution ("QKD") between a quantum communication ("QC") card, base station and trusted authority are described herein. In example implementations, a QC card contains a miniaturized QC transmitter and couples with a base station. The base station provides a network connection with the trusted authority and can also provide electric power to the QC card. When coupled to the base station, after authentication by the trusted authority, the QC card acquires keys through QKD with a trusted authority. The keys can be used to set up secure communication, for authentication, for access control, or formore » other purposes. The QC card can be implemented as part of a smart phone or other mobile computing device, or the QC card can be used as a fillgun for distribution of the keys.« less
Park, Kang Min; Kim, Sung Eun; Lee, Byung In
2016-01-01
The pathogenesis of card game-induced reflex epilepsy has not been determined so far. The aim of this study was to evaluate structural abnormalities using voxel-based morphometry (VBM) analysis, which may give some clue about the pathogenesis in card game-induced reflex epilepsy. The 3 subjects were diagnosed with card game-induced reflex epilepsy. Evaluation involved a structured interview to obtain clinical information and brain MRI. In VBM analysis, Statistical Parametric Mapping 8 running on the MATLAB platform was employed to analyze the structural differences between patients with card game-induced reflex epilepsy and age- and sex-matched control subjects. The results of VBM analysis revealed that patients with card game-induced reflex epilepsy had significantly increased gray matter volume in the right occipital and parietal lobe. However, there were no structures with decreased gray matter volume in patients with card game-induced reflex epilepsy compared with control subjects. In addition, we found that the patients with card game-induced reflex epilepsy had onset of seizures in adulthood rather than in adolescence, and all of the patients were men. The parieto-occipital lobes might be partially involved in the neuronal network responsible for card game-induced reflex epilepsy. © 2016 S. Karger AG, Basel.
Procurement Cards Pave the Way to Efficient Purchasing.
ERIC Educational Resources Information Center
Enos, Eileen D.
1999-01-01
As educators battle restricted budgets, inflation, and enrollment changes, strategic sourcing management is replacing traditional transaction-based procurement. Procurement-card programs, allowing organizations to use credit cards for small purchases or low-value items, save time and enhance controls over merchants, credit limits, issuance limits,…
Development of testing and training simulator for CEDMCS in KSNP
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nam, C. H.; Park, C. Y.; Nam, J. I.
2006-07-01
This paper presents a newly developed testing and training simulator (TTS) for automatically diagnosing and tuning the Control Element Drive Mechanism Control System (CEDMCS). TTS includes a new automatic, diagnostic, method for logic control cards and a new tuning method for phase synchronous pulse cards. In Korea Standard Nuclear Power Plants (KSNP). reactor trips occasionally occur due to a damaged logic control card in CEDMCS. However, there is no pre-diagnostic tester available to detect a damaged card in CEDMCS before it causes a reactor trip. Even after the reactor trip occurs, it is difficult to find the damaged card. Tomore » find the damaged card. ICT is usually used. ICT is an automated, computer-controlled testing system with measurement capabilities for testing active and passive components, or clusters of components, on printed circuit boards (PCB) and/or assemblies. However, ICT cannot detect a time dependent fault correctly and requires removal of the waterproof mating to perform the test. Therefore, the additional procedure of re-coating the PCB card is required after the test. TTS for CEDMCS is designed based on real plant conditions, both electrically and mechanically. Therefore, the operator can operate the Control Element Drive Mechanism (CEDM), which is mounted on the closure head of the reactor vessel (RV) using the soft control panel in ITS, which duplicates the Main Control Board (MCB) in the Main Control Room (MCR). However, during the generation of electric power in a nuclear power plant, it is difficult to operate the CEDM so a CEDM and Control Element Assembly (CEA) mock-up facility was developed to simulate a real plant CEDM. ITS was used for diagnosing and tuning control logic cards in CEDMCS in the Ulchin Nuclear Power Plant No. 4 during the plant overhaul period. It exhibited good performance in detecting the damaged cards and tuning the phase synchronous pulse cards. In addition, TTS was useful in training the CEDMCS operator by supplying detail signal information from the logic cards. (authors)« less
The research on visual industrial robot which adopts fuzzy PID control algorithm
NASA Astrophysics Data System (ADS)
Feng, Yifei; Lu, Guoping; Yue, Lulin; Jiang, Weifeng; Zhang, Ye
2017-03-01
The control system of six degrees of freedom visual industrial robot based on the control mode of multi-axis motion control cards and PC was researched. For the variable, non-linear characteristics of industrial robot`s servo system, adaptive fuzzy PID controller was adopted. It achieved better control effort. In the vision system, a CCD camera was used to acquire signals and send them to video processing card. After processing, PC controls the six joints` motion by motion control cards. By experiment, manipulator can operate with machine tool and vision system to realize the function of grasp, process and verify. It has influence on the manufacturing of the industrial robot.
Leccese, Fabio; Cagnetti, Marco; Trinca, Daniele
2014-01-01
A smart city application has been realized and tested. It is a fully remote controlled isle of lamp posts based on new technologies. It has been designed and organized in different hierarchical layers, which perform local activities to physically control the lamp posts and transmit information with another for remote control. Locally, each lamp post uses an electronic card for management and a ZigBee tlc network transmits data to a central control unit, which manages the whole isle. The central unit is realized with a Raspberry-Pi control card due to its good computing performance at very low price. Finally, a WiMAX connection was tested and used to remotely control the smart grid, thus overcoming the distance limitations of commercial Wi-Fi networks. The isle has been realized and tested for some months in the field. PMID:25529206
Leccese, Fabio; Cagnetti, Marco; Trinca, Daniele
2014-12-18
A smart city application has been realized and tested. It is a fully remote controlled isle of lamp posts based on new technologies. It has been designed and organized in different hierarchical layers, which perform local activities to physically control the lamp posts and transmit information with another for remote control. Locally, each lamp post uses an electronic card for management and a ZigBee tlc network transmits data to a central control unit, which manages the whole isle. The central unit is realized with a Raspberry-Pi control card due to its good computing performance at very low price. Finally, a WiMAX connection was tested and used to remotely control the smart grid, thus overcoming the distance limitations of commercial Wi-Fi networks. The isle has been realized and tested for some months in the field.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lawrence, J.D.
1970-03-12
The Control Data 405 card reader, modified by the Control Data 3649 card read controller, is the primary mechanism for transferring information from a deck of punched cards into the CDC 6600 and CDC 7600 computers of the LLL Octopus system. The card reader operates at a maximum rate of 1200 cards per minute. A description of the card reader and its operation is given. A discussion of formates is included. (RWR)
Wang, Ke; Nirmalathas, Ampalavanapillai; Lim, Christina; Skafidas, Efstratios; Alameh, Kamal
2013-07-01
In this paper, we propose and experimentally demonstrate a free-space based high-speed reconfigurable card-to-card optical interconnect architecture with broadcast capability, which is required for control functionalities and efficient parallel computing applications. Experimental results show that 10 Gb/s data can be broadcast to all receiving channels for up to 30 cm with a worst-case receiver sensitivity better than -12.20 dBm. In addition, arbitrary multicasting with the same architecture is also investigated. 10 Gb/s reconfigurable point-to-point link and multicast channels are simultaneously demonstrated with a measured receiver sensitivity power penalty of ~1.3 dB due to crosstalk.
A Cost Effective System Design Approach for Critical Space Systems
NASA Technical Reports Server (NTRS)
Abbott, Larry Wayne; Cox, Gary; Nguyen, Hai
2000-01-01
NASA-JSC required an avionics platform capable of serving a wide range of applications in a cost-effective manner. In part, making the avionics platform cost effective means adhering to open standards and supporting the integration of COTS products with custom products. Inherently, operation in space requires low power, mass, and volume while retaining high performance, reconfigurability, scalability, and upgradability. The Universal Mini-Controller project is based on a modified PC/104-Plus architecture while maintaining full compatibility with standard COTS PC/104 products. The architecture consists of a library of building block modules, which can be mixed and matched to meet a specific application. A set of NASA developed core building blocks, processor card, analog input/output card, and a Mil-Std-1553 card, have been constructed to meet critical functions and unique interfaces. The design for the processor card is based on the PowerPC architecture. This architecture provides an excellent balance between power consumption and performance, and has an upgrade path to the forthcoming radiation hardened PowerPC processor. The processor card, which makes extensive use of surface mount technology, has a 166 MHz PowerPC 603e processor, 32 Mbytes of error detected and corrected RAM, 8 Mbytes of Flash, and I Mbytes of EPROM, on a single PC/104-Plus card. Similar densities have been achieved with the quad channel Mil-Std-1553 card and the analog input/output cards. The power management built into the processor and its peripheral chip allows the power and performance of the system to be adjusted to meet the requirements of the application, allowing another dimension to the flexibility of the Universal Mini-Controller. Unique mechanical packaging allows the Universal Mini-Controller to accommodate standard COTS and custom oversized PC/104-Plus cards. This mechanical packaging also provides thermal management via conductive cooling of COTS boards, which are typically designed for convection cooling methods.
Holo-Chidi video concentrator card
NASA Astrophysics Data System (ADS)
Nwodoh, Thomas A.; Prabhakar, Aditya; Benton, Stephen A.
2001-12-01
The Holo-Chidi Video Concentrator Card is a frame buffer for the Holo-Chidi holographic video processing system. Holo- Chidi is designed at the MIT Media Laboratory for real-time computation of computer generated holograms and the subsequent display of the holograms at video frame rates. The Holo-Chidi system is made of two sets of cards - the set of Processor cards and the set of Video Concentrator Cards (VCCs). The Processor cards are used for hologram computation, data archival/retrieval from a host system, and for higher-level control of the VCCs. The VCC formats computed holographic data from multiple hologram computing Processor cards, converting the digital data to analog form to feed the acousto-optic-modulators of the Media lab's Mark-II holographic display system. The Video Concentrator card is made of: a High-Speed I/O (HSIO) interface whence data is transferred from the hologram computing Processor cards, a set of FIFOs and video RAM used as buffer for data for the hololines being displayed, a one-chip integrated microprocessor and peripheral combination that handles communication with other VCCs and furnishes the card with a USB port, a co-processor which controls display data formatting, and D-to-A converters that convert digital fringes to analog form. The co-processor is implemented with an SRAM-based FPGA with over 500,000 gates and controls all the signals needed to format the data from the multiple Processor cards into the format required by Mark-II. A VCC has three HSIO ports through which up to 500 Megabytes of computed holographic data can flow from the Processor Cards to the VCC per second. A Holo-Chidi system with three VCCs has enough frame buffering capacity to hold up to thirty two 36Megabyte hologram frames at a time. Pre-computed holograms may also be loaded into the VCC from a host computer through the low- speed USB port. Both the microprocessor and the co- processor in the VCC can access the main system memory used to store control programs and data for the VCC. The Card also generates the control signals used by the scanning mirrors of Mark-II. In this paper we discuss the design of the VCC and its implementation in the Holo-Chidi system.
Pinto, Mary Beth; Mansfield, Phylis M; Parente, Diane H
2004-06-01
College-age consumers are one of the groups most highly targeted by credit card marketers. While some college students use their credit cards wisely, others are unable to control their spending. The objective of this study was to investigate differences in attitude toward credit cards and the psychological factors of self-esteem and locus of control among college students who possess one or more credit cards. Attitude was operationalized to include three underlying components: cognitive, affective, and behavioral. We separated credit users into subcategories based on amount of installment debt. Convenience users were defined as those consumers who paid the credit-card balance in full each month. Installment users were classified as consumers who carried a balance month-to-month. Convenience users were compared to mild and heavy installment users to assess significance of differences in attitudinal and psychological factors. There were no significant differences in the psychological factors across the credit-card user groups. In addition, there was a statistically significant difference on each of the attitude components (knowledge/beliefs, affect, and behavior) across user groups; convenience users, mild installment, and heavy installment users.
Computer system for scanning tunneling microscope automation
NASA Astrophysics Data System (ADS)
Aguilar, M.; García, A.; Pascual, P. J.; Presa, J.; Santisteban, A.
1987-03-01
A computerized system for the automation of a scanning tunneling microscope is presented. It is based on an IBM personal computer (PC) either an XT or an AT, which performs the control, data acquisition and storage operations, displays the STM "images" in real time, and provides image processing tools for the restoration and analysis of data. It supports different data acquisition and control cards and image display cards. The software has been designed in a modular way to allow the replacement of these cards and other equipment improvements as well as the inclusion of user routines for data analysis.
NASA Astrophysics Data System (ADS)
Prejean-Harris, Rose M.
Over the last decade, accountability has been the driving force for many changes in education in the United States. One major educational reform effort is the standards-based movement with a focus of combining a number of processes that involve aligning curriculum, instruction, assessment and feedback to specific standards that are measureable and indicative of student achievement. The purpose of this study is to determine if the type of report card is a possible predictor of third grade student achievement on standardized tests in mathematics and science for the 2012 Criterion-Referenced Competency Test (CRCT). The results of this study concluded that the difference in test scores in mathematics and science for students in the traditional report card group was not statistically significant when compared to the scores of students in the standards-based report card group when controlling for poverty level, school locale, and school district. However, students in the traditional report card group scored an average of 1.01 point higher in mathematics and 2.27 points higher in science than students in the standards-based report card group.
Carded Tow Real-Time Color Assessment: A Spectral Camera-Based System.
Furferi, Rocco; Governi, Lapo; Volpe, Yary; Carfagni, Monica
2016-08-31
One of the most important parameters to be controlled during the production of textile yarns obtained by mixing pre-colored fibers, is the color correspondence between the manufactured yarn and a given reference, usually provided by a designer or a customer. Obtaining yarns from raw pre-colored fibers is a complex manufacturing process entailing a number of steps such as laboratory sampling, color recipe corrections, blowing, carding and spinning. Carding process is the one devoted to transform a "fuzzy mass" of tufted fibers into a regular mass of untwisted fibers, named "tow". During this process, unfortunately, the correspondence between the color of the tow and the target one cannot be assured, thus leading to yarns whose color differs from the one used for reference. To solve this issue, the main aim of this work is to provide a system able to perform a spectral camera-based real-time measurement of a carded tow, to assess its color correspondence with a reference carded fabric and, at the same time, to monitor the overall quality of the tow during the carding process. Tested against a number of differently colored carded fabrics, the proposed system proved its effectiveness in reliably assessing color correspondence in real-time.
Determinants affecting consumer adoption of contactless credit card: an empirical study.
Wang, Yu-Min
2008-12-01
The contactless credit card is one of the most promising technological innovations in the field of electronic payments. It provides consumers with greater control of payments, convenience, and transaction speed. However, contactless credit cards have yet to gain significant rates of adoption in the marketplace. Thus, effort must be made to identify factors affecting consumer adoption of contactless credit cards. Based on the technology acceptance model, innovation diffusion theory, and the relevant literature, seven variables (perceived usefulness, perceived ease of use, compatibility, perceived risk, trust, consumer involvement, availability of infrastructure) are proposed to help predict consumer adoption of contactless credit cards. Data collected from 312 respondents in Taiwan is tested against the proposed prediction model using the logistic regression approach. The results and implications of our study contribute to an expanded understanding of the factors that affect consumer adoption of contactless credit cards.
Self-control and credit-card use among college students.
Mansfield, Phylis M; Pinto, Mary Beth; Parente, Diane H
2003-06-01
This study assessed the relationship between self-control and credit-card use with a convenience sample of 165 traditional-age college students of whom 69 (42%) were women. Students' self-control was measured on Grasmick, et al.'s Self-control Scale, which has six subscales, one of which is Impulsivity. Comparisons were made between those students who paid their cards off each month, called convenience users, and those who carried a monthly balance forward on scores on total self-control and impulsivity, and number of credit cards possessed. A significant difference in self-control scores was found between these two groups and also for mean impulsivity scores. Significantly fewer credit cards were possessed by students who paid their cards off each month than by those who carried a monthly balance.
Front-end electronics for PWO-based PHOS calorimeter of ALICE
NASA Astrophysics Data System (ADS)
Muller, Hans; Budnikov, Dmitry; Ippolitov, Mikhail; Li, Qingxia; Manko, Vladislav; Pimenta, Rui; Rohrich, Dieter; Sibiryak, Iouri; Skaali, Bernhard; Vinogradov, Alexandre
2006-11-01
The electromagnetic Photon Spectrometer (PHOS) of ALICE consists of five modules with 56×64 PWO crystals, operated at -25 °C. Glued to each crystal are APD diodes which amplify a lightyield of 4.4 photoelectrons/MeV, followed by charge-sensitive pre-amplifiers with a charge conversion gain of ca. 1 V/pC. We describe our new 32-channel shaper/digitizer and readout electronics for gain-programmable photodiodes. These Front-End Electronics (FEE) cards are installed below the crystals in an isolated warm volume in geometrical correspondence to 2×16 crystal rows per card. With a total detector capacitance of 100 pF and a noise level of 3 MeV, the FEEs cover a 14 bit dynamic range from 5 MeV to 80 GeV. The low noise level is achieved by operating the APDs and preamplifiers at low temperature and by applying a relatively long shaping time of 1 μs. The offline timing resolution, obtained via a Gamma-2 fit is less than 2 ns. The second-order, dual-gain shapers produce semi-Gaussian output for 10 bit ADCs with embedded multi-event buffers. A Readout Control Unit (RCU) masters data readout with address-mapped access to the event-buffers and controls registers via a custom bus which interconnects up to 14 FEE cards. Programmable bias voltage controllers on the FEE cards allow for very precise gain adjustment of each individual APD. Being co-designed with the TRU trigger cards, each FEE card generates eight fast signal sums (2×2 crystals) as input to the TRU. FPGA-based algorithms generate level-0 and level-1 trigger decisions at 40 MHz and allow PHOS also to operate in self-triggered mode. Inside each PHOS module there are 112 FEE and 8 TRU cards which dissipate ca. 1 kW heat which is extracted via a water cooling system.
Carded Tow Real-Time Color Assessment: A Spectral Camera-Based System
Furferi, Rocco; Governi, Lapo; Volpe, Yary; Carfagni, Monica
2016-01-01
One of the most important parameters to be controlled during the production of textile yarns obtained by mixing pre-colored fibers, is the color correspondence between the manufactured yarn and a given reference, usually provided by a designer or a customer. Obtaining yarns from raw pre-colored fibers is a complex manufacturing process entailing a number of steps such as laboratory sampling, color recipe corrections, blowing, carding and spinning. Carding process is the one devoted to transform a “fuzzy mass” of tufted fibers into a regular mass of untwisted fibers, named “tow”. During this process, unfortunately, the correspondence between the color of the tow and the target one cannot be assured, thus leading to yarns whose color differs from the one used for reference. To solve this issue, the main aim of this work is to provide a system able to perform a spectral camera-based real-time measurement of a carded tow, to assess its color correspondence with a reference carded fabric and, at the same time, to monitor the overall quality of the tow during the carding process. Tested against a number of differently colored carded fabrics, the proposed system proved its effectiveness in reliably assessing color correspondence in real-time. PMID:27589765
NASA Technical Reports Server (NTRS)
Hall, William A.
1990-01-01
Slave microprocessors in multimicroprocessor computing system contains modified circuit cards programmed via bus connecting master processor with slave microprocessors. Enables interactive, microprocessor-based, single-loop control. Confers ability to load and run program from master/slave bus, without need for microprocessor development station. Tristate buffers latch all data and information on status. Slave central processing unit never connected directly to bus.
Iserbyt, Peter; Byra, Mark
2013-11-01
Research investigating design effects of instructional tools for learning Basic Life Support (BLS) is almost non-existent. To demonstrate the design of instructional tools matter. The effect of spatial contiguity, a design principle stating that people learn more deeply when words and corresponding pictures are placed close (i.e., integrated) rather than far from each other on a page was investigated on task cards for learning Cardiopulmonary Resuscitation (CPR) during reciprocal peer learning. A randomized controlled trial. A total of 111 students (mean age: 13 years) constituting six intact classes learned BLS through reciprocal learning with task cards. Task cards combine a picture of the skill with written instructions about how to perform it. In each class, students were randomly assigned to the experimental group or the control. In the control, written instructions were placed under the picture on the task cards. In the experimental group, written instructions were placed close to the corresponding part of the picture on the task cards reflecting application of the spatial contiguity principle. One-way analysis of variance found significantly better performances in the experimental group for ventilation volumes (P=.03, ηp2=.10) and flow rates (P=.02, ηp2=.10). For chest compression depth, compression frequency, compressions with correct hand placement, and duty cycles no significant differences were found. This study shows that the design of instructional tools (i.e., task cards) affects student learning. Research-based design of learning tools can enhance BLS and CPR education. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
A cost-effective add-on-value card-assisted firewall over Taiwan's NHI VPN framework.
Huang, Jyh-Win; Hou, Ting-Wei
2007-06-01
Besides the overall budget for building the infrastructure of a healthcare-service-based virtual private network (VPN) in Taiwan, two issues were considered critical for its acceptance by the country's 17,000 plus medical institutions. One was who was to pay for the network (ADSL or modem) connection fee; the other was who was to pay for the firewall/anti-virus software. This paper addresses the second issue by proposing an efficient freeware firewall, named card-assisted firewall (CAF), for NHI VPN edge-hosts, which is also an add-on-value application of the National Healthcare IC card that every insurant and medical professional has. The innovative concept is that any NHI VPN site (edge-host) can establish diversified secure-authenticated connections with other sites only by an authentication mechanism, which requires a NHI Java card state machine and the Access Control List of the host. It is different from two-factor authentication cards in four ways: (1) a PIN code is not a must; (2) it requires authentication with the remote IC card Data Centre; (3) the NHI cards are already available, no modification is needed, and there is no further cost for the deployment of the cards; (4) although the cards are in the reader, the communication cannot start unless the cards are in the corresponding states; i.e. the states allow communication. An implementation, on a Microsoft Windows XP platform, demonstrated the system's feasibility over an emulation of the NHI VPN framework. It maintained a high line speed, the driver took up 39 KB of disk space, installation was simple, not requiring any extra hardware or software, and the average packet processing time of the CAF driver measured was 0.3084 ms. The average overhead in comparing the Access Control List predefined routing in card, in an FTP testing experiment, was 5.7 micros (receiving) and 8 micros (sending).
Safeer, Richard; Bowen, Wendy; Maung, Zaw; Lucik, Meg
2018-02-01
The aim of this study was to determine whether the Centers for Disease Control and Prevention Worksite Health ScoreCard (ScoreCard) is an effective vehicle for measuring workplace health promotion programs and causing change in a large employer with multiple entities defined by different physical environments and types of workers. Johns Hopkins Medicine (JHM) representatives completed a baseline ScoreCard for each of their entities. In the subsequent year, improvement of the ScoreCard was tied to leadership performance evaluation. JHM year over year scores were analyzed, along with comparisons to national benchmarks. Eleven of the 12 JHM entities improved their overall score from year one to year two and the JHM enterprise surpassed national benchmarks in year two. Organizations can use the ScoreCard as an effective measurement tool and as a method to improve the number of evidenced-based health promotion strategies provided to their employees.
DIABCARD a smart card for patients with chronic diseases.
Engelbrecht, R; Hildebrand, C
1997-01-01
Within the European Union-sponsored project DIABCARD, the core of a chip-card-based medical information system for patients with chronic diseases, exemplified on diabetes mellitus, has been developed. The long-term goal of the project is to improve the medical record and the quality of care for patients with chronic diseases. The basic idea is to have a portable electronic medical record on a smart card. This will improve the communication between the different healthcare personnel and between different institutions and, at the same time, promote shared care. The DIABCARD chip-card-based medical information system will offer controlled access to the necessary and up-to-date patient record to everyone involved in the patient's treatment, and it will help reduce the constantly rising healthcare expenditure. The system first was implemented in a small version. The system architecture contains hardware, software, and orgware. It considers especially the memory of the chip card, the processor, the data structure, security functions, the operating system on the chip card, the interface between the chip card and the application, and various application areas. The DIABCARD dataset was defined via an information model, which describes the different communication processes, via acknowledged diabetes datasets and medical scenarios. It includes, among others, emergency data, data for quality assurance, and data for blood glucose self-monitoring. The first prototype has been developed, and a pilot was run for 3 months.
EuCARD2: enhanced accelerator research and development in Europe
NASA Astrophysics Data System (ADS)
Romaniuk, Ryszard S.
2013-10-01
Accelerator science and technology is one of a key enablers of the developments in the particle physic, photon physics and also applications in medicine and industry. EuCARD2 is an European research project which will be realized during 2013-2017 inside the EC FP7 framework. The project concerns the development and coordination of European Accelerator Research and Development. The project is particularly important, to a number of domestic laboratories, due to some plans to build large accelerator infrastructure in Poland. Large accelerator infrastructure of fundamental and applied research character stimulates around it the development and industrial applications as well as biomedical of advanced accelerators, material research and engineering, cryo-technology, mechatronics, robotics, and in particular electronics - like networked measurement and control systems, sensors, computer systems, automation and control systems. The paper presents a digest of the European project EuCARD2 which is Enhanced European Coordination for Accelerator Research and Development. The paper presents a digest of the research results and assumptions in the domain of accelerator science and technology in Europe, shown during the final fourth annual meeting of the EuCARD - European Coordination of Accelerator R&D, and the kick-off meeting of the EuCARD2. There are debated a few basic groups of accelerator systems components like: measurement - control networks of large geometrical extent, multichannel systems for large amounts of metrological data acquisition, precision photonic networks of reference time, frequency and phase distribution, high field magnets, superconducting cavities, novel beam collimators, etc. The paper bases on the following materials: Internet and Intranet documents combined with EuCARD2, Description of Work FP7 EuCARD-2 DoW-312453, 2013-02-13, and discussions and preparatory materials worked on by Eucard-2 initiators.
25 CFR 543.10 - What are the minimum internal control standards for card games?
Code of Federal Regulations, 2013 CFR
2013-04-01
... games? 543.10 Section 543.10 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN... control standards for card games? (a) Supervision. Supervision must be provided as needed during the card... personnel independent of the transaction or independent of the card games department; or (2) A dealer may...
25 CFR 543.10 - What are the minimum internal control standards for card games?
Code of Federal Regulations, 2014 CFR
2014-04-01
... games? 543.10 Section 543.10 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN... control standards for card games? (a) Supervision. Supervision must be provided as needed during the card... personnel independent of the transaction or independent of the card games department; or (2) A dealer may...
ERIC Educational Resources Information Center
Ellis, Albert
1986-01-01
Examines the emotional control card techniques developed by Sklare, Taylor, and Hyland (1985) to help clients more effectively use the rational-emotive imagery technique of Ellis (1974). Suggests a revision of the emotional control card technique. (NB)
Security Enhanced EMV-Based Mobile Payment Protocol
2014-01-01
Near field communication has enabled customers to put their credit cards into a smartphone and use the phone for credit card transaction. But EMV contactless payment allows unauthorized readers to access credit cards. Besides, in offline transaction, a merchant's reader cannot verify whether a card has been revoked. Therefore, we propose an EMV-compatible payment protocol to mitigate the transaction risk. And our modifications to the EMV standard are transparent to merchants and users. We also encrypt the communications between a card and a reader to prevent eavesdropping on sensitive data. The protocol is able to resist impersonation attacks and to avoid the security threats in EMV. In offline transactions, our scheme requires a user to apply for a temporary offline certificate in advance. With the certificate, banks no longer need to lower customer's credits for risk control, and users can have online-equivalent credits in offline transactions. PMID:25302334
Security enhanced EMV-based mobile payment protocol.
Yang, Ming-Hour
2014-01-01
Near field communication has enabled customers to put their credit cards into a smartphone and use the phone for credit card transaction. But EMV contactless payment allows unauthorized readers to access credit cards. Besides, in offline transaction, a merchant's reader cannot verify whether a card has been revoked. Therefore, we propose an EMV-compatible payment protocol to mitigate the transaction risk. And our modifications to the EMV standard are transparent to merchants and users. We also encrypt the communications between a card and a reader to prevent eavesdropping on sensitive data. The protocol is able to resist impersonation attacks and to avoid the security threats in EMV. In offline transactions, our scheme requires a user to apply for a temporary offline certificate in advance. With the certificate, banks no longer need to lower customer's credits for risk control, and users can have online-equivalent credits in offline transactions.
Location Based Application Availability
NASA Astrophysics Data System (ADS)
Naeem Akram, Raja; Markantonakis, Konstantinos; Mayes, Keith
Smart cards are being integrated into a diverse range of industries: ranging from banking, telecom, transport, home/office access control to health and E-passport. Traditionally, cardholders are required to carry a smart card for each application. However, recent developments in the Near Field Communication (NFC) have renewed the interest in multiple applications for different services on a single device. This paper builds onto the NFC initiative and avoids the smart card ownership issues that hinder the adoption of such devices. The proposal integrates the Global Positioning System with the NFC in mobile phones to provide a ubiquitously and flexible service access model.
[The continuous graphic presentation of interdepartmental results (author's transl)].
Berger, J; Hirsch, H
1976-10-01
The results of interdepartmental determinations can be clearly presented in the laboratory in two ways: 1. Entry on a test card, according to Shewhart, as used in internal quality control. 2. Entry on a test card, constructed on the principle of the Cusum test. By the latter procedure, systematic errors are detected sooner than with the usual test card. A graphic variant of the Cusum test is described; a V-mask is not required; the card superficially resembles the usual control card, and the calculation time is minimal. This method may also be used to advantage in internal quality control.
Lamas, Bruno; Michel, Marie-Laure; Waldschmitt, Nadine; Pham, Hang-Phuong; Zacharioudaki, Vassiliki; Dupraz, Louise; Delacre, Myriam; Natividad, Jane M; Costa, Gregory Da; Planchais, Julien; Sovran, Bruno; Bridonneau, Chantal; Six, Adrien; Langella, Philippe; Richard, Mathias L; Chamaillard, Mathias; Sokol, Harry
2017-08-08
In association with innate and adaptive immunity, the microbiota controls the colonisation resistance against intestinal pathogens. Caspase recruitment domain 9 ( CARD9 ), a key innate immunity gene, is required to shape a normal gut microbiota. Card9 -/- mice are more susceptible to the enteric mouse pathogen Citrobacter rodentium that mimics human infections with enteropathogenic and enterohaemorrhagic Escherichia coli . Here, we examined how CARD9 controls C. rodentium infection susceptibility through microbiota-dependent and microbiota-independent mechanisms. C. rodentium infection was assessed in conventional and germ-free (GF) wild-type (WT) and Card9 -/- mice. To explore the impact of Card9 -/- microbiota in infection susceptibility, GF WT mice were colonised with WT (WT→GF) or Card9 -/- ( Card9 -/- →GF) microbiota before C. rodentium infection. Microbiota composition was determined by 16S rDNA gene sequencing. Inflammation severity was determined by histology score and lipocalin level. Microbiota-host immune system interactions were assessed by quantitative PCR analysis. CARD9 controls pathogen virulence in a microbiota-independent manner by supporting a specific humoral response. Higher susceptibility to C. rodentium -induced colitis was observed in Card9 -/- →GF mice. The microbiota of Card9 -/- mice failed to outcompete the monosaccharide-consuming C. rodentium , worsening the infection severity. A polysaccharide-enriched diet counteracted the ecological advantage of C. rodentium and the defective pathogen-specific antibody response in Card9 -/- mice. CARD9 modulates the susceptibility to intestinal infection by controlling the pathogen virulence in a microbiota-dependent and microbiota-independent manner. Genetic susceptibility to intestinal pathogens can be overridden by diet intervention that restores humoural immunity and a competing microbiota. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
[New electronic data carriers in Bosnia-Herzegovina].
Masić, I; Pandza, H; Knezević, Z; Toromanović, S
1999-01-01
Bosnia and Herzegovina has been developing new Health Care System based on Electronic Registration Card. Developing countries proceeded from the manual and semiautomatic method of medical data processing to the new method of entering, storage, transfer, searching and protection of data using electronic equipment. Currently, many European countries have developed a Medical Card Based Electronic Information System. Both technologies offer the advantages and disadvantages. Three types of electronic card are currently in use: Hybrid Card, Smart Card and Laser Card. Hybrid Card offers characteristics of both Smart Card and Laser Card. The differences among these cards, such as a capacity, total price, price per byte, security system are discussed here. The dilemma is, which card should be used as a data carrier. The Electronic Family Registration Card is a question of strategic interest for B&H, but also a big investment. We should avoid the errors of other countries that have been developing card-based system. In this article we present all mentioned cards and compare advantages and disadvantages of different technologies.
NASA Astrophysics Data System (ADS)
Miwa, Shotaro; Kage, Hiroshi; Hirai, Takashi; Sumi, Kazuhiko
We propose a probabilistic face recognition algorithm for Access Control System(ACS)s. Comparing with existing ACSs using low cost IC-cards, face recognition has advantages in usability and security that it doesn't require people to hold cards over scanners and doesn't accept imposters with authorized cards. Therefore face recognition attracts more interests in security markets than IC-cards. But in security markets where low cost ACSs exist, price competition is important, and there is a limitation on the quality of available cameras and image control. Therefore ACSs using face recognition are required to handle much lower quality images, such as defocused and poor gain-controlled images than high security systems, such as immigration control. To tackle with such image quality problems we developed a face recognition algorithm based on a probabilistic model which combines a variety of image-difference features trained by Real AdaBoost with their prior probability distributions. It enables to evaluate and utilize only reliable features among trained ones during each authentication, and achieve high recognition performance rates. The field evaluation using a pseudo Access Control System installed in our office shows that the proposed system achieves a constant high recognition performance rate independent on face image qualities, that is about four times lower EER (Equal Error Rate) under a variety of image conditions than one without any prior probability distributions. On the other hand using image difference features without any prior probabilities are sensitive to image qualities. We also evaluated PCA, and it has worse, but constant performance rates because of its general optimization on overall data. Comparing with PCA, Real AdaBoost without any prior distribution performs twice better under good image conditions, but degrades to a performance as good as PCA under poor image conditions.
A powerful enhancement to the DMAP alter capability
NASA Technical Reports Server (NTRS)
Pamidi, P. R.
1989-01-01
A powerful enhancement to the DMAP alter capability was developed and is available on all RPK-supported versions of COSMIC/NASTRAN. This enhancement involves the addition of two alter control cards, called INSERT and DELETE, to the Executive Control Deck. These cards allow for DMAP alters to be made by referencing DMAP statements by their module names rather than by their statement numbers in the rigid format DMAP sequence. This allows for increased user convenience and flexibility and makes alters more meaningful to the user. In addition, DMAP alter packages employing the alter control cards will be much less susceptible to future changes in rigid format DMAPs than alter packages employing the standard ALTER control cards. The usage of the cards is illustrated by examples.
Schunk, Mirjam; Kebede Mekonnen, Seleshi; Wondafrash, Beyene; Mengele, Carolin; Fleischmann, Erna; Herbinger, Karl-Heinz; Verweij, Jaco J.; Geldmacher, Christof; Bretzel, Gisela; Löscher, Thomas; Zeynudin, Ahmed
2015-01-01
Background In Schistosoma mansoni infection, diagnosis and control after treatment mainly rely on parasitological stool investigations which are laborious and have limited sensitivity. PCR methods have shown equal or superior sensitivity but preservation and storage methods limit their use in the field. Therefore, the use of occult blood detection cards (fecal cards) for easy sampling and storage of fecal samples for further PCR testing was evaluated in a pilot study. Methodology Stool specimens were collected in a highly endemic area for S. mansoni in Ethiopia and submitted in an investigator-blinded fashion to microscopic examination by Kato-Katz thick smear as well as to real-time PCR using either fresh frozen stool samples or stool smears on fecal cards which have been stored at ambient temperature for up to ten months. Principal Findings Out of 55 stool samples, 35 were positive by microscopy, 33 and 32 were positive by PCR of frozen samples and of fecal card samples, respectively. When microscopy was used as diagnostic “gold standard”, the sensitivity of PCR on fresh stool was 94.3% (95%-CI: 86.6; 100) and on fecal cards 91.4% (95%-CI: 82.2; 100). Conclusions The use of fecal cards proved to be a simple and useful method for stool collection and prolonged storage prior to PCR based diagnosis of S. mansoni infection. This technique may be a valuable approach for large scale surveillance and post treatment assessments PMID:26360049
Schunk, Mirjam; Kebede Mekonnen, Seleshi; Wondafrash, Beyene; Mengele, Carolin; Fleischmann, Erna; Herbinger, Karl-Heinz; Verweij, Jaco J; Geldmacher, Christof; Bretzel, Gisela; Löscher, Thomas; Zeynudin, Ahmed
2015-01-01
In Schistosoma mansoni infection, diagnosis and control after treatment mainly rely on parasitological stool investigations which are laborious and have limited sensitivity. PCR methods have shown equal or superior sensitivity but preservation and storage methods limit their use in the field. Therefore, the use of occult blood detection cards (fecal cards) for easy sampling and storage of fecal samples for further PCR testing was evaluated in a pilot study. Stool specimens were collected in a highly endemic area for S. mansoni in Ethiopia and submitted in an investigator-blinded fashion to microscopic examination by Kato-Katz thick smear as well as to real-time PCR using either fresh frozen stool samples or stool smears on fecal cards which have been stored at ambient temperature for up to ten months. Out of 55 stool samples, 35 were positive by microscopy, 33 and 32 were positive by PCR of frozen samples and of fecal card samples, respectively. When microscopy was used as diagnostic "gold standard", the sensitivity of PCR on fresh stool was 94.3% (95%-CI: 86.6; 100) and on fecal cards 91.4% (95%-CI: 82.2; 100). The use of fecal cards proved to be a simple and useful method for stool collection and prolonged storage prior to PCR based diagnosis of S. mansoni infection. This technique may be a valuable approach for large scale surveillance and post treatment assessments.
From cookies to carrots; the effect of inhibitory control training on children's snack selections.
Porter, L; Bailey-Jones, C; Priudokaite, G; Allen, S; Wood, K; Stiles, K; Parvin, O; Javaid, M; Verbruggen, F; Lawrence, N S
2018-05-01
Children consume too much sugar and not enough fruit and vegetables, increasing their risk of adverse health outcomes. Inhibitory control training (ICT) reduces children's and adults' intake of energy-dense foods in both laboratory and real-life settings. However, no studies have yet examined whether ICT can increase healthy food choice when energy-dense options are also available. We investigated whether a food-specific Go/No-Go task could influence the food choices of children aged 4-11, as measured by a hypothetical food choice task using healthy and unhealthy food images printed on cards. Participants played either an active game (healthy foods = 100% go, unhealthy foods = 100% no-go; Studies 1 & 2), a food control game (both healthy and unhealthy foods = 50% go, 50% no-go; Studies 1 & 2) or a non-food control game (sports equipment = 100% go, technology = 100% no-go; Study 2 only) followed by the choice task. In Study 2, food card choices were also measured before training to examine change in choices. A post-training real food choice task was added to check that choices made in the card-based task were representative of choices made when faced with real healthy and unhealthy foods. Overall, the active group chose the greatest number of healthy food cards. Study 2 confirmed that this was due to increases in healthy food card choice in this group only. Active group participants chose a greater number of healthy foods in the real food choice task compared to children in the non-food control group only. The results are discussed with reference to methodological issues and the development of future healthy eating interventions. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Smart cards: a specific application in the hospital.
Güler, I; Zengin, R M; Sönmez, M
1998-12-01
Computers have the ability to process and access tremendous amounts of information in our daily lives. But, now, individuals have this ability by carrying a smart card in their own wallets. These cards provide us the versatility, power, and security of computers. This study begins with a short description of smart cards and their advantages. Then, an electronic circuit that is designed for healthcare application in hospitals is introduced. This circuit functions as a smart card holder identifier, access controller for hospital doors and also can be used as a smart card reader/writer. Design steps of this electronic circuit, operation principles, serial communication with P.C., and the software are examined. Finally a complete access control network for hospital doors that functions with smart cards is discussed.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 38-MOTOR EQUIPMENT MANAGEMENT 38.8-Standard Form 149, U.S. Government National Credit Card § 109-38... the administrative control of fleet credit cards. Administrative control shall include, as a minimum: (1) A reconciliation of on-hand credit cards with the inventory list provided by GSA, (2) Providing...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 38-MOTOR EQUIPMENT MANAGEMENT 38.8-Standard Form 149, U.S. Government National Credit Card § 109-38... the administrative control of fleet credit cards. Administrative control shall include, as a minimum: (1) A reconciliation of on-hand credit cards with the inventory list provided by GSA, (2) Providing...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 38-MOTOR EQUIPMENT MANAGEMENT 38.8-Standard Form 149, U.S. Government National Credit Card § 109-38... the administrative control of fleet credit cards. Administrative control shall include, as a minimum: (1) A reconciliation of on-hand credit cards with the inventory list provided by GSA, (2) Providing...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 38-MOTOR EQUIPMENT MANAGEMENT 38.8-Standard Form 149, U.S. Government National Credit Card § 109-38... the administrative control of fleet credit cards. Administrative control shall include, as a minimum: (1) A reconciliation of on-hand credit cards with the inventory list provided by GSA, (2) Providing...
48 CFR 1313.301 - Governmentwide commercial purchase card.
Code of Federal Regulations, 2010 CFR
2010-10-01
... purchase card. 1313.301 Section 1313.301 Federal Acquisition Regulations System DEPARTMENT OF COMMERCE....301 Governmentwide commercial purchase card. The Department's procedures for the use and control of the Governmentwide commercial purchase card are set forth in CAM 1313.301. ...
HyperCLIPS: A HyperCard interface to CLIPS
NASA Technical Reports Server (NTRS)
Pickering, Brad; Hill, Randall W., Jr.
1990-01-01
HyperCLIPS combines the intuitive, interactive user interface of the Apple Macintosh(TM) with the powerful symbolic computation of an expert system interpreter. HyperCard(TM) is an excellent environment for quickly developing the front end of an application with buttons, dialogs, and pictures, while the CLIPS interpreter provides a powerful inference engine for complex problem solving and analysis. By integrating HyperCard and CLIPS the advantages and uses of both packages are made available for a wide range of uses: rapid prototyping of knowledge-based expert systems, interactive simulations of physical systems, and intelligent control of hypertext processes, to name a few. Interfacing HyperCard and CLIPS is natural. HyperCard was designed to be extended through the use of external commands (XCMDs), and CLIPS was designed to be embedded through the use of the I/O router facilities and callable interface routines. With the exception of some technical difficulties which will be discussed later, HyperCLIPS implements this interface in a straight forward manner, using the facilities provided. An XCMD called 'ClipsX' was added to HyperCard to give access to the CLIPS routines: clear, load, reset, and run. And an I/O router was added to CLIPS to handle the communication of data between CLIPS and HyperCard.
Event-Driven Random-Access-Windowing CCD Imaging System
NASA Technical Reports Server (NTRS)
Monacos, Steve; Portillo, Angel; Ortiz, Gerardo; Alexander, James; Lam, Raymond; Liu, William
2004-01-01
A charge-coupled-device (CCD) based high-speed imaging system, called a realtime, event-driven (RARE) camera, is undergoing development. This camera is capable of readout from multiple subwindows [also known as regions of interest (ROIs)] within the CCD field of view. Both the sizes and the locations of the ROIs can be controlled in real time and can be changed at the camera frame rate. The predecessor of this camera was described in High-Frame-Rate CCD Camera Having Subwindow Capability (NPO- 30564) NASA Tech Briefs, Vol. 26, No. 12 (December 2002), page 26. The architecture of the prior camera requires tight coupling between camera control logic and an external host computer that provides commands for camera operation and processes pixels from the camera. This tight coupling limits the attainable frame rate and functionality of the camera. The design of the present camera loosens this coupling to increase the achievable frame rate and functionality. From a host computer perspective, the readout operation in the prior camera was defined on a per-line basis; in this camera, it is defined on a per-ROI basis. In addition, the camera includes internal timing circuitry. This combination of features enables real-time, event-driven operation for adaptive control of the camera. Hence, this camera is well suited for applications requiring autonomous control of multiple ROIs to track multiple targets moving throughout the CCD field of view. Additionally, by eliminating the need for control intervention by the host computer during the pixel readout, the present design reduces ROI-readout times to attain higher frame rates. This camera (see figure) includes an imager card consisting of a commercial CCD imager and two signal-processor chips. The imager card converts transistor/ transistor-logic (TTL)-level signals from a field programmable gate array (FPGA) controller card. These signals are transmitted to the imager card via a low-voltage differential signaling (LVDS) cable assembly. The FPGA controller card is connected to the host computer via a standard peripheral component interface (PCI).
Cuvo, A J; Klatt, K P
1992-01-01
Community-referenced sight words and phrases were taught to adolescents with mild and moderate mental retardation using three instructional methods in two locations. Words were presented on flash cards in a school setting, on videotape recordings in a school setting, and on naturally occurring signs in the community. During each session, participants were taught one third of the words in each of these conditions and were then tested at the community sites. A constant prompt delay procedure was used to promote stimulus control to the experimenter's cue initially and then to transfer control to the textual stimuli used for training. A multiple baseline across participants design was employed. Results showed rapid acquisition of the community-referenced sight words in all three training conditions and generalization from the flash card and videotape conditions to the community sites. PMID:1378827
Family Registration Card as electronic medical carrier in Bosnia and Herzegovina.
Novo, Ahmed; Masic, Izet; Toromanovic, Selim; Loncarevic, Nedim; Junuzovic, Dzelaludin; Dizdarevic, Jadranka
2004-01-01
Medical documentation is a very important part of the medical documentalistics and is occupies a large part of daily work of medical staff working in Primary Health Care. Paper documentation is going to be replaced by electronic cards in Bosnia and Herzegovina and a new Health Care System is under development, based on an Electronic Family Registration Card. Developed countries proceeded from the manual and semiautomatic method of medical data processing to the new method of entering, storage, transferring, searching and protecting data, using electronic equipment. Currently, many European countries have developed a Medical Card Based Electronic Information System. Three types of electronic card are currently in use: a Hybrid Card, a Smart Card and a Laser Card. The dilemma is which card should be used as a data carrier. The Electronic Family Registration Cared is a question of strategic interest for B&H, but also a great investment. We should avoid the errors of other countries that have been developing card-based system. In this article we present all mentioned cards and compare advantages and disadvantages of different technologies.
Code of Federal Regulations, 2014 CFR
2014-07-01
... with the manufacturer's instructions. Interim controls means a set of measures designed to temporarily... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT LEAD-BASED... disposable cleaning cloths with the card, whether post-renovation cleaning has been properly completed...
Code of Federal Regulations, 2013 CFR
2013-07-01
... with the manufacturer's instructions. Interim controls means a set of measures designed to temporarily... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT LEAD-BASED... disposable cleaning cloths with the card, whether post-renovation cleaning has been properly completed...
Code of Federal Regulations, 2012 CFR
2012-07-01
... with the manufacturer's instructions. Interim controls means a set of measures designed to temporarily... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT LEAD-BASED... disposable cleaning cloths with the card, whether post-renovation cleaning has been properly completed...
Missile Datcom User’s Manual - 2008 Revision
2008-08-01
and Surface Roughness ........................ 58 Table 24. Magnus derivatives calculated with SPIN Control Card...M.F.E. Dillenius (W.B. Blake) WL-TR-91-3039 (ADA 237817) 5 4/91 Inlets at sub/transonic speeds, additive drag Plume effects on body Six types...control card. This control card has no effect on input angles, input angles are always specified in degrees. Partial output results, which detail the
MST radar transmitter control and monitor system
NASA Technical Reports Server (NTRS)
Brosnahan, J. W.
1983-01-01
A generalized transmitter control and monitor card was developed using the Intel 8031 (8051 family) microprocessor. The design was generalized so that this card can be utilized for virtually any control application with only firmware changes. The block diagram appears in Figure 2. The card provides for local control using a 16 key keypad (up to 64 keys are supported). The local display is four digits of 7 segment LEDs. The display can indicate the status of all major system parameters and provide voltage readout for the analog signal inputs. The card can be populated with only the chips required for a given application. Fully populated, the card has two RS-232 serial ports for computer communications. It has a total of 48 TTL parallel lines that can define as either inputs or outputs in groups of four. A total of 32 analog inputs with a 0-5 volt range are supported. In addition, a real-time clock/calendar is available if required. A total of 16 k bytes of ROM and 16 k bytes of RAM is available for programming. This card can be the basis of virtually any monitor or control system with appropriate software.
Dannewitz, Holly; Weatherly, Jeffrey N
2007-05-01
Cognitive fallacies, such as the illusion of control, and psychological disorders, such as depression, may perpetuate gambling and thus contribute to problem gambling (e.g., R. Ladouceur, C. Sylvan, C. Boutin, & C. Doucet, 2002). Gender differences may exist across these variables (e.g., N. M. Petry, 2005). The authors investigated these possibilities by recruiting mildly depressed and nondepressed individuals to play jacks or better, 5-card draw, video poker. Across three poker sessions, participants were given (a) no choice of which cards to play, (b) information on the best cards to play but control over which cards were played, or (c) no information and complete control over which cards were played. The total amount of money gambled increased as control over the game decreased, but this result correlated with an increase in the rate of play. Depressed and nondepressed participants did not differ in how they gambled, but men gambled significantly more and sometimes made more mistakes during play than did women. These results question the role of the illusion of control and depression in perpetuating gambling. They also suggest that providing players information about which cards to play may indirectly promote gambling and provide insight as to why men are more prone to suffer from gambling problems than are women.
Emerging Technology for School Security
ERIC Educational Resources Information Center
Doss, Kevin T.
2012-01-01
Locks and keys ring up huge costs for education institutions. No wonder many facility directors and public-safety directors have turned to automated access-control systems with magnetic-stripe cards, proximity cards and, most recently, smart cards. Smart cards can provide a host of on- and off-campus services beyond security. In addition to…
NASA Astrophysics Data System (ADS)
Keshet, Aviv; Ketterle, Wolfgang
2013-01-01
Atomic physics experiments often require a complex sequence of precisely timed computer controlled events. This paper describes a distributed graphical user interface-based control system designed with such experiments in mind, which makes use of off-the-shelf output hardware from National Instruments. The software makes use of a client-server separation between a user interface for sequence design and a set of output hardware servers. Output hardware servers are designed to use standard National Instruments output cards, but the client-server nature should allow this to be extended to other output hardware. Output sequences running on multiple servers and output cards can be synchronized using a shared clock. By using a field programmable gate array-generated variable frequency clock, redundant buffers can be dramatically shortened, and a time resolution of 100 ns achieved over effectively arbitrary sequence lengths.
Keshet, Aviv; Ketterle, Wolfgang
2013-01-01
Atomic physics experiments often require a complex sequence of precisely timed computer controlled events. This paper describes a distributed graphical user interface-based control system designed with such experiments in mind, which makes use of off-the-shelf output hardware from National Instruments. The software makes use of a client-server separation between a user interface for sequence design and a set of output hardware servers. Output hardware servers are designed to use standard National Instruments output cards, but the client-server nature should allow this to be extended to other output hardware. Output sequences running on multiple servers and output cards can be synchronized using a shared clock. By using a field programmable gate array-generated variable frequency clock, redundant buffers can be dramatically shortened, and a time resolution of 100 ns achieved over effectively arbitrary sequence lengths.
Code of Federal Regulations, 2010 CFR
2010-07-01
... with none of the air leaking past it. Interim controls means a set of measures designed to temporarily... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT LEAD-BASED... disposable cleaning cloths with the card, whether post-renovation cleaning has been properly completed...
Code of Federal Regulations, 2011 CFR
2011-07-01
... with none of the air leaking past it. Interim controls means a set of measures designed to temporarily... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT LEAD-BASED... disposable cleaning cloths with the card, whether post-renovation cleaning has been properly completed...
Transportable telemetry workstation
NASA Technical Reports Server (NTRS)
Collins, Aaron S.
1989-01-01
The goal was to complete the design of a prototype for a Transportable Telemetry Workstation (TTW). The Macintosh 2 is used to provide a low-cost system which can house real-time cards mounted on the NuBus inside the Macintosh 2 plus provide a standardized user interface on the Macintosh 2 console. Prior to a telemetry run, the user will be able to configure his real-time telemetry processing functions from the Macintosh 2 console. During a telemetry run, the real-time cards will store the telemetry data directly on a hard disk while permitting viewing of the data cards on the Macintosh 2 console on various selectable formats. The user will view the cards in terms of the functions they perform and the selectable paths through the cards, it is not required to become involved directly in hardware issue except in terms of the functional configuration of the system components. The TTW will accept telemetry data from an RS422 serial input data bus, pass it through a frame synchronizer card and on to a real time controller card via a telemetry backplane bus. The controller card will then route the data to a hard disk through a SCSI interface, and/or to a user interface on the Macintosh 2 console by way of the Macintosh 2 NuBus. The three major components to be designed, therefore, are the TTW Controller Card, the TTW Synchronizer Card, and the NuBus/Macintosh 2 User Interface. Design and prototyping of this state-of-the-art, transportable, low-cost, easy-to-use multiprocessor telemetry system is continuing. Other functions are planned for the future.
Transportable telemetry workstation
NASA Astrophysics Data System (ADS)
Collins, Aaron S.
1989-09-01
The goal was to complete the design of a prototype for a Transportable Telemetry Workstation (TTW). The Macintosh 2 is used to provide a low-cost system which can house real-time cards mounted on the NuBus inside the Macintosh 2 plus provide a standardized user interface on the Macintosh 2 console. Prior to a telemetry run, the user will be able to configure his real-time telemetry processing functions from the Macintosh 2 console. During a telemetry run, the real-time cards will store the telemetry data directly on a hard disk while permitting viewing of the data cards on the Macintosh 2 console on various selectable formats. The user will view the cards in terms of the functions they perform and the selectable paths through the cards, it is not required to become involved directly in hardware issue except in terms of the functional configuration of the system components. The TTW will accept telemetry data from an RS422 serial input data bus, pass it through a frame synchronizer card and on to a real time controller card via a telemetry backplane bus. The controller card will then route the data to a hard disk through a SCSI interface, and/or to a user interface on the Macintosh 2 console by way of the Macintosh 2 NuBus. The three major components to be designed, therefore, are the TTW Controller Card, the TTW Synchronizer Card, and the NuBus/Macintosh 2 User Interface. Design and prototyping of this state-of-the-art, transportable, low-cost, easy-to-use multiprocessor telemetry system is continuing. Other functions are planned for the future.
AVR Microcontroller-based automated technique for analysis of DC motors
NASA Astrophysics Data System (ADS)
Kaur, P.; Chatterji, S.
2014-01-01
This paper provides essential information on the development of a 'dc motor test and analysis control card' using AVR series ATMega32 microcontroller. This card can be interfaced to PC and calculates parameters like motor losses, efficiency and plot characteristics for dc motors. Presently, there are different tests and methods available to evaluate motor parameters, but a single and universal user-friendly automated set-up has been discussed in this paper. It has been accomplished by designing a data acquisition and SCR bridge firing hardware based on AVR ATMega32 microcontroller. This hardware has the capability to drive the phase-controlled rectifiers and acquire real-time values of current, voltage, temperature and speed of motor. Various analyses feasible with the designed hardware are of immense importance for dc motor manufacturers and quality-sensitive users. Authors, through this paper aim to provide details of this AVR-based hardware which can be used for dc motor parameter analysis and also for motor control applications.
Duckworth, Angela L.; Quinn, Patrick D.; Tsukayama, Eli
2013-01-01
The increasing prominence of standardized testing to assess student learning motivated the current investigation. We propose that standardized achievement test scores assess competencies determined more by intelligence than by self-control, whereas report card grades assess competencies determined more by self-control than by intelligence. In particular, we suggest that intelligence helps students learn and solve problems independent of formal instruction, whereas self-control helps students study, complete homework, and behave positively in the classroom. Two longitudinal, prospective studies of middle school students support predictions from this model. In both samples, IQ predicted changes in standardized achievement test scores over time better than did self-control, whereas self-control predicted changes in report card grades over time better than did IQ. As expected, the effect of self-control on changes in report card grades was mediated in Study 2 by teacher ratings of homework completion and classroom conduct. In a third study, ratings of middle school teachers about the content and purpose of standardized achievement tests and report card grades were consistent with the proposed model. Implications for pedagogy and public policy are discussed. PMID:24072936
In vitro reconstitution of interactions in the CARD9 signalosome
Park, Jin Hee; Choi, Jae Young; Mustafa, Mir Faisal; Park, Hyun Ho
2017-01-01
The caspase-associated recruitment domain (CARD)-containing protein 9 (CARD9) signalosome is composed of CARD9, B-cell CLL/lymphoma 10 (BCL10) and mucosa-associated lymphoid tissue lymphoma translocation protein 1 (MALT1). The CARD9 signalosome has been reported to exert critical functions in the immunoreceptor tyrosine-based activation motif-coupled receptor-mediated activation of myeloid cells, through nuclear factor-κB pathways during innate immunity processes. During CARD9 signalosome assembly, BCL10 has been revealed to function as an adaptor protein and to interact with CARD9 via CARD-CARD interactions; BCL10 also interacts with MALT1 via its C-terminal Ser/Thr-rich region and the first immunoglobulin domain of MALT1. The CARD9 signalosome is implicated in critical biological processes; however, its structural and biochemical characteristics have yet to be elucidated. In the present study, CARD9 and BCL10 CARDs were successfully purified and characterized, and their biochemical properties were investigated. In addition, CARD9-BCL10 complexes were reconstituted in vitro under low salt and pH conditions. Furthermore, based on structural modeling data, a scheme was proposed to describe the interactions between CARD9 and BCL10. This provides a further understanding of the mechanism of how the CARD9 signalosome may be assembled. PMID:28765954
ERIC Educational Resources Information Center
Watson, Stevie
2009-01-01
This study examined attitudinal and behavioral differences between internal and external locus of control (LOC) consumers on credit card misuse, the importance of money, and compulsive buying. Using multiple analysis of variance and separate analyses of variance, internal LOC consumers were found to have lower scores on credit card misuse and…
Assessing Semantic Knowledge Using Computer-Based and Paper-Based Media
1992-01-01
capitalized upon in this research. Computer-Based Assessment A computer-based game or test, FlashCards (Liggett & Federico, 1986), was adopt- ed and adapted...alterative forms did not have to be specifically or previously programmed as such. FlashCards is analogous to using real flash cards. That is, a...reflects their degree of confidence in their answer. Also, for each answer the student’s response latency is recorded and displayed. FlashCards quizzed
Integrating Fingerprint Verification into the Smart Card-Based Healthcare Information System
NASA Astrophysics Data System (ADS)
Moon, Daesung; Chung, Yongwha; Pan, Sung Bum; Park, Jin-Won
2009-12-01
As VLSI technology has been improved, a smart card employing 32-bit processors has been released, and more personal information such as medical, financial data can be stored in the card. Thus, it becomes important to protect personal information stored in the card. Verification of the card holder's identity using a fingerprint has advantages over the present practices of Personal Identification Numbers (PINs) and passwords. However, the computational workload of fingerprint verification is much heavier than that of the typical PIN-based solution. In this paper, we consider three strategies to implement fingerprint verification in a smart card environment and how to distribute the modules of fingerprint verification between the smart card and the card reader. We first evaluate the number of instructions of each step of a typical fingerprint verification algorithm, and estimate the execution time of several cryptographic algorithms to guarantee the security/privacy of the fingerprint data transmitted in the smart card with the client-server environment. Based on the evaluation results, we analyze each scenario with respect to the security level and the real-time execution requirements in order to implement fingerprint verification in the smart card with the client-server environment.
Punch Card Programmable Microfluidics
Korir, George; Prakash, Manu
2015-01-01
Small volume fluid handling in single and multiphase microfluidics provides a promising strategy for efficient bio-chemical assays, low-cost point-of-care diagnostics and new approaches to scientific discoveries. However multiple barriers exist towards low-cost field deployment of programmable microfluidics. Incorporating multiple pumps, mixers and discrete valve based control of nanoliter fluids and droplets in an integrated, programmable manner without additional required external components has remained elusive. Combining the idea of punch card programming with arbitrary fluid control, here we describe a self-contained, hand-crank powered, multiplex and robust programmable microfluidic platform. A paper tape encodes information as a series of punched holes. A mechanical reader/actuator reads these paper tapes and correspondingly executes operations onto a microfluidic chip coupled to the platform in a plug-and-play fashion. Enabled by the complexity of codes that can be represented by a series of holes in punched paper tapes, we demonstrate independent control of 15 on-chip pumps with enhanced mixing, normally-closed valves and a novel on-demand impact-based droplet generator. We demonstrate robustness of operation by encoding a string of characters representing the word “PUNCHCARD MICROFLUIDICS” using the droplet generator. Multiplexing is demonstrated by implementing an example colorimetric water quality assays for pH, ammonia, nitrite and nitrate content in different water samples. With its portable and robust design, low cost and ease-of-use, we envision punch card programmable microfluidics will bring complex control of microfluidic chips into field-based applications in low-resource settings and in the hands of children around the world. PMID:25738834
Punch card programmable microfluidics.
Korir, George; Prakash, Manu
2015-01-01
Small volume fluid handling in single and multiphase microfluidics provides a promising strategy for efficient bio-chemical assays, low-cost point-of-care diagnostics and new approaches to scientific discoveries. However multiple barriers exist towards low-cost field deployment of programmable microfluidics. Incorporating multiple pumps, mixers and discrete valve based control of nanoliter fluids and droplets in an integrated, programmable manner without additional required external components has remained elusive. Combining the idea of punch card programming with arbitrary fluid control, here we describe a self-contained, hand-crank powered, multiplex and robust programmable microfluidic platform. A paper tape encodes information as a series of punched holes. A mechanical reader/actuator reads these paper tapes and correspondingly executes operations onto a microfluidic chip coupled to the platform in a plug-and-play fashion. Enabled by the complexity of codes that can be represented by a series of holes in punched paper tapes, we demonstrate independent control of 15 on-chip pumps with enhanced mixing, normally-closed valves and a novel on-demand impact-based droplet generator. We demonstrate robustness of operation by encoding a string of characters representing the word "PUNCHCARD MICROFLUIDICS" using the droplet generator. Multiplexing is demonstrated by implementing an example colorimetric water quality assays for pH, ammonia, nitrite and nitrate content in different water samples. With its portable and robust design, low cost and ease-of-use, we envision punch card programmable microfluidics will bring complex control of microfluidic chips into field-based applications in low-resource settings and in the hands of children around the world.
[Card-based age control mechanisms at tobacco vending machines. Effect and consequences].
Schneider, S; Meyer, C; Löber, S; Röhrig, S; Solle, D
2010-02-01
Until recently, 700,000 tobacco vending machines provided uncontrolled access to cigarettes for children and adolescents in Germany. On January 1, 2007, a card-based electronic locking device was attached to all tobacco vending machines to prevent the purchase of cigarettes by children and adolescents under 16. Starting in 2009, only persons older than 18 are able to buy cigarettes from tobacco vending machines. The aim of the present investigation (SToP Study: "Sources of Tobacco for Pupils" Study) was to assess changes in the number of tobacco vending machines after the introduction of these new technical devices (supplier's reaction). In addition, the ways smoking adolescents make purchases were assessed (consumer's reaction). We registered and mapped the total number of tobacco points of sale (tobacco POS) before and after the introduction of the card-based electronic locking device in two selected districts of the city of Cologne. Furthermore, pupils from local schools (response rate: 83%) were asked about their tobacco consumption and ways of purchase using a questionnaire. Results indicated that in the area investigated the total number of tobacco POSs decreased from 315 in 2005 to 277 in 2007. The rates of decrease were 48% for outdoor vending machines and 8% for indoor vending machines. Adolescents reported circumventing the card-based electronic locking devices (e.g., by using cards from older friends) and using other tobacco POSs (especially newspaper kiosks) or relying on their social network (mainly friends). The decreasing number of tobacco vending machines has not had a significant impact on cigarette acquisition by adolescent smokers as they tend to circumvent the newly introduced security measures.
A Mechanism for Anonymous Credit Card Systems
NASA Astrophysics Data System (ADS)
Tamura, Shinsuke; Yanase, Tatsuro
This paper proposes a mechanism for anonymous credit card systems, in which each credit card holder can conceal individual transactions from the credit card company, while enabling the credit card company to calculate the total expenditures of transactions of individual card holders during specified periods, and to identify card holders who executed dishonest transactions. Based on three existing mechanisms, i.e. anonymous authentication, blind signature and secure statistical data gathering, together with implicit transaction links proposed here, the proposed mechanism enables development of anonymous credit card systems without assuming any absolutely trustworthy entity like tamper resistant devices or organizations faithful both to the credit card company and card holders.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-21
... card, a household's shopping behavior is three times more likely to be flagged as potential [[Page... many first-time users do not understand how to use the card and a grace period in the beginning would... that a replacement card is not needed every time the benefits are spent down or that once a card is...
Common Badging and Access Control System (CBACS)
NASA Technical Reports Server (NTRS)
Baldridge, Tim
2005-01-01
The goals of the project are: Achieve high business value through a common badging and access control system that integrates with smart cards. Provide physical (versus logical) deployment of smart cards initially. Provides a common consistent and reliable environment into which to release the smart card. Gives opportunity to develop agency-wide consistent processes, practices and policies. Enables enterprise data capture and management. Promotes data validation prior to SC issuance.
Low Power Near Field Communication Methods for RFID Applications of SIM Cards.
Chen, Yicheng; Zheng, Zhaoxia; Gong, Mingyang; Yu, Fengqi
2017-04-14
Power consumption and communication distance have become crucial challenges for SIM card RFID (radio frequency identification) applications. The combination of long distance 2.45 GHz radio frequency (RF) technology and low power 2 kHz near distance communication is a workable scheme. In this paper, an ultra-low frequency 2 kHz near field communication (NFC) method suitable for SIM cards is proposed and verified in silicon. The low frequency transmission model based on electromagnetic induction is discussed. Different transmission modes are introduced and compared, which show that the baseband transmit mode has a better performance. The low-pass filter circuit and programmable gain amplifiers are applied for noise reduction and signal amplitude amplification. Digital-to-analog converters and comparators are used to judge the card approach and departure. A novel differential Manchester decoder is proposed to deal with the internal clock drift in range-controlled communication applications. The chip has been fully implemented in 0.18 µm complementary metal-oxide-semiconductor (CMOS) technology, with a 330 µA work current and a 45 µA idle current. The low frequency chip can be integrated into a radio frequency SIM card for near field RFID applications.
The Ins and Outs of Access Control.
ERIC Educational Resources Information Center
Longworth, David
1999-01-01
Presents basic considerations when school districts plan to acquire an access-control system for their education facilities. Topics cover cards and readers, controllers, software, automation, card technology, expandability, price, specification of needs beyond the canned specifications already supplied, and proper usage training to cardholders.…
Qin, Juan-Juan; Mao, Wenzhe; Wang, Xiaozhan; Sun, Peng; Cheng, Daqing; Tian, Song; Zhu, Xue-Yong; Yang, Ling; Huang, Zan; Li, Hongliang
2018-06-26
The comprehensive interplay in sterile inflammation and liver cell death predominantly determines hepatic injury caused by ischemia/reperfusion (I/R) insult. Caspase recruitment domain family member 6 (CARD6) was initially shown to play important roles in NF-κB activation. In our preliminary studies, CARD6 downregulation was closely related to hepatic I/R injury in liver transplantation patients and mouse models. Thus, we hypothesized that CARD6 protects against hepatic I/R injury and investigated the underlying molecular mechanisms. A partial hepatic I/R operation was performed in hepatocyte-specific Card6 knockout mice (HKO), Card6 transgenic mice with CARD6 overexpression specifically in hepatocytes (HTG), and the corresponding control mice. Hepatic histology, serum aminotransferase, inflammatory cytokines/chemokines, cell death, and inflammatory signaling were examined to assess liver damage. The molecular mechanisms of CARD6 function were explored in vivo and in vitro. Card6-HTG mice alleviated liver injury compared with control mice as shown by decreased cell death, lower serum transaminase levels, and reduced inflammation and infiltration, whereas Card6-HKO mice had the opposite phenotype. Mechanistically, phosphorylation of ASK1 and its downstream effectors JNK and p38 were increased in the livers of Card6-HKO mice but repressed in those of Card6-HTG mice. Furthermore, ASK1 knockdown normalized the effect of CARD6 deficiency on the activation of NF-κB, JNK and p38, while ASK1 overexpression abrogated the suppressive effect of CARD6. Finally, CARD6 interacted with Ask1. Mutant CARD6 that lacked the ability to interact with ASK1 could not inhibit ASK1 and failed to protect against hepatic I/R injury. CARD6 is a novel protective factor of hepatic I/R injury that suppresses inflammation and liver cell death by inhibiting the ASK1 signaling pathway. CARD6 participate and play an important role during the process of liver blood flow restriction followed by restoring. Through suppressing the activity of ASK1, CARD6 can protect against hepatocytes injury. Targeting CARD6 can be a strategy for precaution and treatment of this disease. Copyright © 2018 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.
Design and implementation of a smart card based healthcare information system.
Kardas, Geylani; Tunali, E Turhan
2006-01-01
Smart cards are used in information technologies as portable integrated devices with data storage and data processing capabilities. As in other fields, smart card use in health systems became popular due to their increased capacity and performance. Their efficient use with easy and fast data access facilities leads to implementation particularly widespread in security systems. In this paper, a smart card based healthcare information system is developed. The system uses smart card for personal identification and transfer of health data and provides data communication via a distributed protocol which is particularly developed for this study. Two smart card software modules are implemented that run on patient and healthcare professional smart cards, respectively. In addition to personal information, general health information about the patient is also loaded to patient smart card. Health care providers use their own smart cards to be authenticated on the system and to access data on patient cards. Encryption keys and digital signature keys stored on smart cards of the system are used for secure and authenticated data communication between clients and database servers over distributed object protocol. System is developed on Java platform by using object oriented architecture and design patterns.
[Smart card systems in health care (protection, key-functions, divided data bases, applications)].
Simon, P
1999-04-25
Barely more than 15 years have passed since electronic memory cards appeared, their popularity has grown rapidly (first of all as a cash-saving device and later for other purposes, as well). This is due also to the growing interest towards development of the intelligence of information systems for the follow-up of patients' health condition and medical care in countries with a highly developed health and insurance system (need for the creation of data bases divided for individuals) and also to their commitment towards a better control of the quality and costs of health care. We can come to the conclusion that the aim of research, development and the creation of systems in health informatics is to prevent illness and to give a direct informatic support to medical and nursing activity carried out in the patients' interests. The smart card and the surrounding application systems are certainly the appropriate means for the achievement of these aims.
NASA Astrophysics Data System (ADS)
Wojenski, Andrzej; Kasprowicz, Grzegorz; Pozniak, Krzysztof T.; Romaniuk, Ryszard
2013-10-01
The paper describes a concept of automatic firmware generation for reconfigurable measurement systems, which uses FPGA devices and measurement cards in FMC standard. Following sections are described in details: automatic HDL code generation for FPGA devices, automatic communication interfaces implementation, HDL drivers for measurement cards, automatic serial connection between multiple measurement backplane boards, automatic build of memory map (address space), automatic generated firmware management. Presented solutions are required in many advanced measurement systems, like Beam Position Monitors or GEM detectors. This work is a part of a wider project for automatic firmware generation and management of reconfigurable systems. Solutions presented in this paper are based on previous publication in SPIE.
Citizen empowerment using healthcare and welfare cards.
Cheshire, Paul
2006-01-01
Cards are used in health and welfare to establish the identity of the person presenting the card; to prove their entitlement to a welfare or healthcare service; to store data needed within the care process; and to store data to use in the administration process. There is a desire to empower citizens - to give them greater control over their lives, their health and wellbeing. How can a healthcare and welfare card support this aim? Does having a card empower the citizen? What can a citizen do more easily, reliably, securely or cost-effectively because they have a card? A number of possibilities include: Choice of service provider; Mobility across regional and national boundaries; Privacy; and Anonymity. But in all of these possibilities a card is just one component of a total system and process, and there may be other solutions--technological and manual. There are risks and problems from relying on a card; and issues of Inclusion for people who are unable use a card. The article concludes that: cards need to be viewed in the context of the whole solution; cards are not the only technological mechanism; cards are not the best mechanism in all circumstances; but cards are very convenient method in very many situations.
NASA Technical Reports Server (NTRS)
Jorgensen, James H.; Skweres, Joyce A.; Mishra S. K.; McElmeel, M. Letticia; Maher, Louise A.; Mulder, Ross; Lancaster, Michael V.; Pierson, Duane L.
1997-01-01
Very little is known regarding the affects of the microgravity environment of space flight upon the action of antimicrobial agents on bacterial pathogens. This study was undertaken to develop a simple method for conducting antibacterial susceptibility tests during a Space Shuttle mission. Specially prepared susceptibility test research cards (bioMerieux Vitek, Hazelwood, MO) were designed to include 6-11 serial two-fold dilutions of 14 antimicrobial agents, including penicillins, cephalosporins, a Beta-lactamase inhibitor, vancomycin, erythromycin, tetracycline, gentamicin, ciprofloxacin, and trimethoprim/sulfamethoxazole. Minimal inhibitory concentrations (MICS) of the drugs were determined by visual reading of color endpoints in the Vitek research cards made possible by incorporation of a colorimetric growth indicator (alamarBlue(Trademark), Accumed International, Westlake, OH). This study has demonstrated reproducible susceptibility results when testing isolates of Staphylococcus aurezis, Group A Streptococcus, Enterococcusfaecalis, Escherichia coli (beta-lactamase positive and negative strains), Klebsiella pneumoniae, Enterobacter cloacae, and Pseudomoiias aeruginosa. In some instances, the MICs were comparable to those determined using a standard broth microdilution method, while in some cases the unique test media and format yielded slightly different values, that were themselves reproducible. The proposed in-flight experiment will include inoculation of the Vitek cards on the ground prior to launch of the Space Shuttle, storage of inoculated cards at refrigeration temperature aboard the Space Shuttle until experiment initiation, then incubation of the cards for 18-48 h prior to visual interpretation of MICs by the mission's astronauts. Ground-based studies have shown reproducible MICs following storage of inoculated cards for 7 days at 4-8 C to accommodate the mission's time schedule and the astronauts' activities. For comparison, ground-based control (normal gravity) MIC values will be generated by simultaneous inoculation and incubation of a second set of test cards in a laboratory at the launch site. This procedure can provide a safe and compact experiment that should yield new information on the affects of microgravity on the biological activities of various classes of antibiotics.
Research on the SIM card implementing functions of transport card
NASA Astrophysics Data System (ADS)
Li, Yi; Wang, Lin
2015-12-01
This paper is based on the analysis for theory and key technologies of contact communication, contactless communication card and STK menu, and proposes complete software and hardware solution for achieving convenience and secure mobile payment system on SIM card.
FLUID/MASHOV--A CAI System Based on Games, Dialogue, and Feedback.
ERIC Educational Resources Information Center
Regev, Joseph
1980-01-01
A master program to manage instruction and generate the necessary control cards was designed to both teach thinking skills and assist the teacher in assessing the student's thought processes. Twelve references are cited. (MER)
Stille, C J; Christison-Lagay, J; Bernstein, B A; Dworkin, P H
2001-07-01
We sought to determine if a simple educational intervention initiated at the first well-child care visit, with reinforcement at subsequent visits, can improve inner-city infant immunization rates. We conducted a controlled trial involving 315 newborn infants and their primary caregivers in 3 inner-city primary care centers. Child health care providers gave caregivers in the intervention group an interactive graphic card with verbal reinforcement. At later visits, stickers were applied to the card when immunizations were given. Routine information was given to controls. After the trial, age-appropriate immunization rates at 7 months were 58% in each group. Intervention infants had 50% fewer missed opportunities to immunize (p=0.01) but cancelled 77% more appointments (p=0.04) than controls. We conclude that a brief educational intervention at the first well-child care visit did not boost 7-month immunization rates, although it was associated with fewer missed opportunities to immunize.
PC/AT-based architecture for shared telerobotic control
NASA Astrophysics Data System (ADS)
Schinstock, Dale E.; Faddis, Terry N.; Barr, Bill G.
1993-03-01
A telerobotic control system must include teleoperational, shared, and autonomous modes of control in order to provide a robot platform for incorporating the rapid advances that are occurring in telerobotics and associated technologies. These modes along with the ability to modify the control algorithms are especially beneficial for telerobotic control systems used for research purposes. The paper describes an application of the PC/AT platform to the control system of a telerobotic test cell. The paper provides a discussion of the suitability of the PC/AT as a platform for a telerobotic control system. The discussion is based on the many factors affecting the choice of a computer platform for a real time control system. The factors include I/O capabilities, simplicity, popularity, computational performance, and communication with external systems. The paper also includes a description of the actuation, measurement, and sensor hardware of both the master manipulator and the slave robot. It also includes a description of the PC-Bus interface cards. These cards were developed by the researchers in the KAT Laboratory, specifically for interfacing to the master manipulator and slave robot. Finally, a few different versions of the low level telerobotic control software are presented. This software incorporates shared control by supervisory systems and the human operator and traded control between supervisory systems and the human operator.
Bergmann, Hanna; Roth, Susanne; Pechloff, Konstanze; Kiss, Elina A; Kuhn, Sabine; Heikenwälder, Mathias; Diefenbach, Andreas; Greten, Florian R; Ruland, Jürgen
2017-08-01
Inflammatory bowel diseases (IBD) are key risk factors for the development of colorectal cancer, but the mechanisms that link intestinal inflammation with carcinogenesis are insufficiently understood. Card9 is a myeloid cell-specific signaling protein that regulates inflammatory responses downstream of various pattern recognition receptors and which cooperates with the inflammasomes for IL-1β production. Because polymorphisms in Card9 were recurrently associated with human IBD, we investigated the function of Card9 in a colitis-associated cancer (CAC) model. Card9 -/- mice develop smaller, less proliferative and less dysplastic tumors compared to their littermates and in the regenerating mucosa we detected dramatically impaired IL-1β generation and defective IL-1β controlled IL-22 production from group 3 innate lymphoid cells. Consistent with the key role of immune-derived IL-22 in activating STAT3 signaling during normal and pathological intestinal epithelial cell (IEC) proliferation, Card9 -/- mice also exhibit impaired tumor cell intrinsic STAT3 activation. Our results imply a Card9-controlled, ILC3-mediated mechanism regulating healthy and malignant IEC proliferation and demonstrates a role of Card9-mediated innate immunity in inflammation-associated carcinogenesis. © 2017 The Authors. European Journal of Immunology published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
CODAP: Control Card Specifications for the Univac 1108.
ERIC Educational Resources Information Center
Stacey, William D.; And Others
The document is one of three in a series of technical reports covering the control card and programing aspects of the Comprehensive Occupational Data Analysis Programs (CODAP), a highly interactive and efficient system of computer routines for analyzing, organizing, and reporting occupational information. The document contains control card…
25 CFR 543.23 - What are the minimum internal control standards for audit and accounting?
Code of Federal Regulations, 2014 CFR
2014-04-01
... supervision, bingo cards, bingo card sales, draw, prize payout; cash and equivalent controls, technologic aids... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for audit... INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.23 What are the...
25 CFR 543.23 - What are the minimum internal control standards for audit and accounting?
Code of Federal Regulations, 2013 CFR
2013-04-01
... supervision, bingo cards, bingo card sales, draw, prize payout; cash and equivalent controls, technologic aids... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for audit... INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.23 What are the...
Wang, Ke; Nirmalathas, Ampalavanapillai; Lim, Christina; Skafidas, Efstratios; Alameh, Kamal
2014-10-01
In this Letter, we propose and experimentally demonstrate a free-space based reconfigurable card-to-card optical interconnect architecture with 16-carrierless-amplitude-phase modulation. Experimental results show that up to 120 Gb/s (3×40 Gb/s) flexible interconnection can be achieved for up to 30 cm distance with a worst-case receiver sensitivity of -9.70 dBm.
Design of transnational mobile e-payment application based on SIM card
NASA Astrophysics Data System (ADS)
Qian, Tang; Zhen, Li
2018-05-01
Facing the stronger demands of transnational mobile communications and internet-based mobile wireless value-added services, the interconnection and interworking of multiple communication operators and their win-win cooperations become a crucial target in the new round of mobile economic development. Previous researches showed that mobile communications and value-add services are not only technical problems, but also more economic problems.we design a general oncard operating system based on SIM card that could be responsible for coordinating and distributing card hardware and software resources. These applications such as transnational mobile payment, consumption management and many other supplemented functions share the API interfaces, hardware and software resources provided by the operation system, although they are independent of each other. The layer structure of SIM card design not only greatly reduces the complexity of COS development, but also saves the most tense card resources and extends SIM cards applications.
77 FR 2685 - Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-19
..., Report of Terms of Credit Card Plans. DATES: Written comments must be received on or before March 19... (202) 435-7678. SUPPLEMENTARY INFORMATION: Title: Report of Terms of Credit Card Plans. OMB Control... of Terms of Credit Card, from the Federal Reserve Board to the CFPB on July 21, 2011. About 150...
Reminder card helps patients remember OCs.
1999-11-01
Organon has developed the Reminder Card to help women patients remember their regular intake of oral contraceptive (OC) pills. About 50% of women take birth control pills as prescribed, 25% miss a pill per month, and 25% miss two or more pills in the same time frame. The plastic card, about the size and shape of a credit card, contains a microchip timer. Reminder cards are available to providers who use the Starter Kits issued by the company for new-start patients on the Mircette OC. When patients begin their first pack of pills, they select the time of day they prefer to have the Reminder Card emit its tiny beep. The time is set into the microchip timer and the card is programmed to sound automatically at the pre-set time each day for the next three months. The direction for using the Reminder Card is outlined.
DOT National Transportation Integrated Search
1995-04-01
This project developed relevant information on existing and future, stored readable/writable data card technology for fare and toll payments. The project supports the FTA objective of developing a plan for a common standard card-based fare payment sy...
Newer Technologies for School Security. ERIC Digest Number 145.
ERIC Educational Resources Information Center
Schneider, Tod
This digest describes several technologies that can be used to control access to, and improve surveillance of, school grounds. Access can be controlled by using "smart" cards to control keyed entries. Many schools have problems with multiple copies of keys, and these card systems are integrated with computer software that allows for…
Commercial Off-The-Shelf (COTS) Graphics Processing Board (GPB) Radiation Test Evaluation Report
NASA Technical Reports Server (NTRS)
Salazar, George A.; Steele, Glen F.
2013-01-01
Large round trip communications latency for deep space missions will require more onboard computational capabilities to enable the space vehicle to undertake many tasks that have traditionally been ground-based, mission control responsibilities. As a result, visual display graphics will be required to provide simpler vehicle situational awareness through graphical representations, as well as provide capabilities never before done in a space mission, such as augmented reality for in-flight maintenance or Telepresence activities. These capabilities will require graphics processors and associated support electronic components for high computational graphics processing. In an effort to understand the performance of commercial graphics card electronics operating in the expected radiation environment, a preliminary test was performed on five commercial offthe- shelf (COTS) graphics cards. This paper discusses the preliminary evaluation test results of five COTS graphics processing cards tested to the International Space Station (ISS) low earth orbit radiation environment. Three of the five graphics cards were tested to a total dose of 6000 rads (Si). The test articles, test configuration, preliminary results, and recommendations are discussed.
CARD 2017: expansion and model-centric curation of the comprehensive antibiotic resistance database
Jia, Baofeng; Raphenya, Amogelang R.; Alcock, Brian; Waglechner, Nicholas; Guo, Peiyao; Tsang, Kara K.; Lago, Briony A.; Dave, Biren M.; Pereira, Sheldon; Sharma, Arjun N.; Doshi, Sachin; Courtot, Mélanie; Lo, Raymond; Williams, Laura E.; Frye, Jonathan G.; Elsayegh, Tariq; Sardar, Daim; Westman, Erin L.; Pawlowski, Andrew C.; Johnson, Timothy A.; Brinkman, Fiona S.L.; Wright, Gerard D.; McArthur, Andrew G.
2017-01-01
The Comprehensive Antibiotic Resistance Database (CARD; http://arpcard.mcmaster.ca) is a manually curated resource containing high quality reference data on the molecular basis of antimicrobial resistance (AMR), with an emphasis on the genes, proteins and mutations involved in AMR. CARD is ontologically structured, model centric, and spans the breadth of AMR drug classes and resistance mechanisms, including intrinsic, mutation-driven and acquired resistance. It is built upon the Antibiotic Resistance Ontology (ARO), a custom built, interconnected and hierarchical controlled vocabulary allowing advanced data sharing and organization. Its design allows the development of novel genome analysis tools, such as the Resistance Gene Identifier (RGI) for resistome prediction from raw genome sequence. Recent improvements include extensive curation of additional reference sequences and mutations, development of a unique Model Ontology and accompanying AMR detection models to power sequence analysis, new visualization tools, and expansion of the RGI for detection of emergent AMR threats. CARD curation is updated monthly based on an interplay of manual literature curation, computational text mining, and genome analysis. PMID:27789705
Design of a motion JPEG (M/JPEG) adapter card
NASA Astrophysics Data System (ADS)
Lee, D. H.; Sudharsanan, Subramania I.
1994-05-01
In this paper we describe a design of a high performance JPEG (Joint Photographic Experts Group) Micro Channel adapter card. The card, tested on a range of PS/2 platforms (models 50 to 95), can complete JPEG operations on a 640 by 240 pixel image within 1/60 of a second, thus enabling real-time capture and display of high quality digital video. The card accepts digital pixels for either a YUV 4:2:2 or an RGB 4:4:4 pixel bus and has been shown to handle up to 2.05 MBytes/second of compressed data. The compressed data is transmitted to a host memory area by Direct Memory Access operations. The card uses a single C-Cube's CL550 JPEG processor that complies with the baseline JPEG. We give broad descriptions of the hardware that controls the video interface, CL550, and the system interface. Some critical design points that enhance the overall performance of the M/JPEG systems are pointed out. The control of the adapter card is achieved by an interrupt driven software that runs under DOS. The software performs a variety of tasks that include change of color space (RGB or YUV), change of quantization and Huffman tables, odd and even field control and some diagnostic operations.
CARD8 rs2043211 polymorphism is associated with gout in a Chinese male population.
Chen, Ying; Ren, Xianfeng; Li, Changgui; Xing, Shichao; Fu, Zhengju; Yuan, Ying; Wang, Robin; Wang, Yangang; Lv, Wenshan
2015-01-01
BACKGROUND &AIM: Previous studies have suggested genetic factors are involved in the development of gout. We performed a case-control study to investigate the genetic association between CARD8 rs2043211 polymorphism and gout. A total of 396 male patients with gout and 403 age- and sex- matched healthy controls were included in this study. Genotyping was performed using TaqMan SNP Genotyping Assays. An association analysis was carried out using the χ² test. The genotype-phenotype analysis was also conducted. The genotype distribution of CARD8 rs2043211 polymorphism confirmed to HWE in the controls (P = 0.27). There was an obvious difference in the genotype distribution of CARD8 rs2043211 polymorphism between cases and controls (P = 0.017). In addition, there was an obvious association between CARD8 rs2043211 polymorphism and gout under the recessive comparison model (AA vs. OR = 0.65, 95%CI 0.47-0.88, P = 0.006). Patients carrying genotype TT of CARD8 rs2043211 polymorphism had higher triglycerides levels compared to those carrying the AA genotype (2.77±2.08 mmol/L vs. 2.07±1.15 mmol/L, P = 0.01). Patients with the TT genotype also had significantly higher systolic blood pressure compared with those with the AA genotype (142.11±21.10 mmHg vs. 135.38±14.66 mmHg, P = 0.03). Patients carrying TT genotype also had an increased risk of renal calculus compared with those carrying the AA genotype. CARD8 rs2043211 polymorphism is significantly associated with susceptibility to gout in Chinese Han males. © 2015 S. Karger AG, Basel.
Disease duration and age influence CARD15 expression in Crohn's disease.
Poniewierka, Elżbieta; Neubauer, Katarzyna; Kempiński, Radosław; Sadakierska-Chudy, Anna
2016-01-05
One of the susceptibility genes in Crohn's disease (CD) is CARD15. Our study examined the relationship between peripheral CARD15 expression and phenotype and duration of CD, treatment methods and inflammatory indices. Sixty patients with CD and 30 healthy volunteers as controls were enrolled in the study. Total RNA was isolated from peripheral blood mononuclear cells (PBMCs) with E.Z.N.A. Total RNA Kit (Omega Bio-tek) then quantitative real-time PCR was performed on the ABI Prism 7900 HT Real-Time PCR System. CARD15 gene expression in PBMCs in CD was significantly higher than in the control group. The highest level of gene expression was found in CD patients in the fourth decade of life. The mRNA level of the CARD15 gene was higher in patients with disease duration between 12 and 60 months. A positive correlation was found between erythrocyte sedimentation rate (ESR) and gene expression level. Gene expression increased with increasing level of C-reactive protein and ESR, but it was not statistically significant. CARD15 expression significantly decreased in CD patients treated with anti-TNFα agents compared to azathioprine or steroid treatment groups. Expression of the CARD15 gene in Crohn›s disease is higher than in healthy individuals. Disease duration and age of patients seem to be the most important factors influencing CARD15 expression.
Eye movements during the Rorschach test in schizophrenia.
Hori, Yasuko; Fukuzako, Hiroshi; Sugimoto, Yoko; Takigawa, Morikuni
2002-08-01
In order to understand relationships between scanning behaviors, characteristics of visual stimuli and the clinical symptoms in schizophrenia, eye movements of 37 schizophrenic patients and 36 controls were recorded using an eye-mark recorder during a free-response period in a Rorschach test. Four cards (I, II, V and VIII) were used. Data were analyzed during 15 s from the presentation of each card. For all cards, the number of eye fixations and the number of eye fixation areas were fewer, and total scanning length and mean scanning length were shorter for schizophrenic patients than for controls. For card II, in the non-popular response group, eye fixation frequency upon area 5 + 6 (red) was higher for schizophrenic patients. For card VIII, in the popular response group, eye fixation frequency upon area 5 + 6 (pink) was lower for schizophrenic patients. For cards II and VIII, the number of eye fixations was inversely correlated with negative symptoms. For card II, total scanning length tended to be inversely correlated with negative symptoms, and mean eye fixation time was correlated with negative symptoms. The number of eye fixation areas was inversely correlated with positive symptoms. For card VIII, eye fixation frequency in a stimulative area tended to be correlated with positive symptoms. Scanning behaviors in schizophrenic patients are affected by characteristics of visual stimuli, and partially by clinical symptoms.
Shovel, Louisa; Max, Bryan; Correll, Darin J
2016-01-01
The purpose of this study was to see if an instructional card, attached to the PCA machine following total hip arthroplasty describing proper use of the device, would positively affect subjects' understanding of device usage, pain scores, pain medication consumption and satisfaction. Eighty adults undergoing total hip replacements who had been prescribed PCA were randomized into two study groups. Forty participants received the standard post-operative instruction on PCA device usage at our institution. The other 40 participants received the standard of care in addition to being given a typed instructional card immediately post-operatively, describing proper PCA device use. This card was attached to the PCA device during their recovery period. On post-operative day one, each patient completed a questionnaire on PCA usage, pain scores and satisfaction scores. The pain scores in the Instructional Card group were significantly lower than the Control group (p = 0.024). Subjects' understanding of PCA usage was also improved in the Instructional Card group for six of the seven questions asked. The findings from this study strongly support that postoperative patient information on proper PCA use by means of an instructional card improves pain control and hence the overall recovery for patients undergoing surgery. In addition, through improved understanding it adds an important safety feature in that patients and potentially their family members and/or friends may refrain from PCA-by-proxy. This article demonstrates that the simple intervention of adding an instructional card to a PCA machine is an effective method to improve patients' knowledge as well as pain control and potentially increase the safety of the device use.
25 CFR 542.9 - What are the minimum internal control standards for card games?
Code of Federal Regulations, 2013 CFR
2013-04-01
... games? 542.9 Section 542.9 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN... card games? (a) Computer applications. For any computer applications utilized, alternate documentation... and count. The procedures for the collection of the card game drop and the count thereof shall comply...
25 CFR 542.9 - What are the minimum internal control standards for card games?
Code of Federal Regulations, 2012 CFR
2012-04-01
... games? 542.9 Section 542.9 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN... card games? (a) Computer applications. For any computer applications utilized, alternate documentation... and count. The procedures for the collection of the card game drop and the count thereof shall comply...
25 CFR 542.9 - What are the minimum internal control standards for card games?
Code of Federal Regulations, 2014 CFR
2014-04-01
... games? 542.9 Section 542.9 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN... card games? (a) Computer applications. For any computer applications utilized, alternate documentation... and count. The procedures for the collection of the card game drop and the count thereof shall comply...
25 CFR 542.9 - What are the minimum internal control standards for card games?
Code of Federal Regulations, 2011 CFR
2011-04-01
... games? 542.9 Section 542.9 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN... card games? (a) Computer applications. For any computer applications utilized, alternate documentation... and count. The procedures for the collection of the card game drop and the count thereof shall comply...
25 CFR 542.9 - What are the minimum internal control standards for card games?
Code of Federal Regulations, 2010 CFR
2010-04-01
... games? 542.9 Section 542.9 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN... card games? (a) Computer applications. For any computer applications utilized, alternate documentation... and count. The procedures for the collection of the card game drop and the count thereof shall comply...
Defense Automation Resources Management Manual
1988-09-01
Electronic Command Signals Programmer, Plugboard Programmers Punch, Card Punch, Paper Tape Reader, Character Reader-Generator, Time Cards Reader...Multiplexor-Shift Register Group Multiplier Panel Control, Plugboard Panel, Interconnection, Digital Computer Panel, Meter-Attenuator, Tape Recorder PC Cards...Perforator, Tape Plug-In Unit Potentiometer, Coefficient, Analog Computer Programmer, Plugboard Punch, Paper Tape Racks Reader, Time Code Reader
How can the German Electronic Health Card support patient's role in care management.
Pharow, Peter; Blobel, Bernd; Hildebrand, Claudia
2008-01-01
All types of advanced communication, collaboration, and cooperation in healthcare require a strong involvement of all addressed parties including health professionals and patients. Modern healthcare aims at involving patients having them take over responsibility for their own health status. Allowing them to take on their changed roles as emancipated partners in advanced care management, health professionals need to be educated and patients need to be empowered. From a security viewpoint, health issues have to be communicated via trusted health networks. To provide communication and cooperation between professionals and patients as well as to guarantee the required level of involvement of patients in shared care management environments, cards are widely used as person identifiers, on the one hand, and as security tokens, on the other. Being introduced as storage media and portable personalized application system, cards enable a patient controlled access to personalized health services as well as proper use and exchange of personal health data for specific purposes such as emergency. Furthermore, cards allow access to the wider electronic patient record via pointers or tickets. Cards can empower patients. The German Electronic Health Card (eGK) shall thus support care management and specific workflow processes e.g. for prescription and disease management. Regardless whether designed as data or pointer card - international standardization is a prerequisite also for national solutions. The more information patients have regarding different procedures and processes in healthcare, the more are they able to play their dedicated role within care management. Cards can and will contribute by allowing patients to get controlled access to administrative and medical data stored either on cards or in networks. Card holders determine who has access to their health information.
ERIC Educational Resources Information Center
Schneider, Tod
This digest in Spanish describes several technologies that can be used to control access to, and improve surveillance of, school grounds. Access can be controlled by using "smart" cards to control keyed entries. Many schools have problems with multiple copies of keys, and these card systems are integrated with computer software that…
Exit Cards: Creating a Dialogue for Continuous Evaluation
ERIC Educational Resources Information Center
Patka, Mazna; Wallin-Ruschman, Jennifer; Wallace, Tenille; Robbins, Candice
2016-01-01
This study explored the use of Exit Cards, which are formative evaluations of student knowledge and instruction undertaken at every class meeting. Its results are based on Exit Card data from two undergraduate research methods courses. Thematic analysis indicated that students used Exit Cards to communicate (1) what they learned, (2) challenges…
ERIC Educational Resources Information Center
Villano, Matt
2008-01-01
Building access control (BAC)--a catchall phrase to describe the systems that control access to facilities across campus--has traditionally been handled with remarkably low-tech solutions: (1) manual locks; (2) electronic locks; and (3) ID cards with magnetic strips. Recent improvements have included smart cards and keyless solutions that make use…
Evaluation and comparison of FTA card and CTAB DNA extraction methods for non-agricultural taxa.
Siegel, Chloe S; Stevenson, Florence O; Zimmer, Elizabeth A
2017-02-01
An efficient, effective DNA extraction method is necessary for comprehensive analysis of plant genomes. This study analyzed the quality of DNA obtained using paper FTA cards prepared directly in the field when compared to the more traditional cetyltrimethylammonium bromide (CTAB)-based extraction methods from silica-dried samples. DNA was extracted using FTA cards according to the manufacturer's protocol. In parallel, CTAB-based extractions were done using the automated AutoGen DNA isolation system. DNA quality for both methods was determined for 15 non-agricultural species collected in situ, by gel separation, spectrophotometry, fluorometry, and successful amplification and sequencing of nuclear and chloroplast gene markers. The FTA card extraction method yielded less concentrated, but also less fragmented samples than the CTAB-based technique. The card-extracted samples provided DNA that could be successfully amplified and sequenced. The FTA cards are also useful because the collected samples do not require refrigeration, extensive laboratory expertise, or as many hazardous chemicals as extractions using the CTAB-based technique. The relative success of the FTA card method in our study suggested that this method could be a valuable tool for studies in plant population genetics and conservation biology that may involve screening of hundreds of individual plants. The FTA cards, like the silica gel samples, do not contain plant material capable of propagation, and therefore do not require permits from the U.S. Department of Agriculture (USDA) Animal and Plant Health Inspection Service (APHIS) for transportation.
The NASTRAN user's manual (level 17.0)
NASA Technical Reports Server (NTRS)
1979-01-01
NASTRAN embodies a lumped element approach, wherein the distributed physical properties of a structure are represented by a model consisting of a finite number of idealized substructures or elements that are interconnected at a finite of grid points, to which loads are applied. All input and output data pertain to the idealized structural model. The general procedures for defining structural models are described and instructions are given for each of the bulk data cards and case control cards. Additional information on the case control cards and use of parameters is included for each rigid format.
User’s Guide for COMBIMAN Programs (COMputerized BIomechanical MAN-Model). Version 4.
1981-01-01
103 2.2.23 STATE SWITCH Function (PFK29) 105 2.2.24 RESTART PROGRAM Function (PFK30) 110 2.2.25 END PROGRAM Function (PFK31) il 2.3 EXECUTING THE JOB...108 40 Transformation Equation Developed for Positioning Stomach Link (Set State Switch 72 ON) 109 41 JOB CONTROL CARDS to Execute CBM04. 114 42...154 50b Program CBMAM Survey Member Dimension Definition Cards. 154 51 Example of Survey, or Type 1, Member. 155 52 Job Control Cards to Execute CBMAM
Authentication techniques for smart cards
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nelson, R.A.
1994-02-01
Smart card systems are most cost efficient when implemented as a distributed system, which is a system without central host interaction or a local database of card numbers for verifying transaction approval. A distributed system, as such, presents special card and user authentication problems. Fortunately, smart cards offer processing capabilities that provide solutions to authentication problems, provided the system is designed with proper data integrity measures. Smart card systems maintain data integrity through a security design that controls data sources and limits data changes. A good security design is usually a result of a system analysis that provides a thoroughmore » understanding of the application needs. Once designers understand the application, they may specify authentication techniques that mitigate the risk of system compromise or failure. Current authentication techniques include cryptography, passwords, challenge/response protocols, and biometrics. The security design includes these techniques to help prevent counterfeit cards, unauthorized use, or information compromise. This paper discusses card authentication and user identity techniques that enhance security for microprocessor card systems. It also describes the analysis process used for determining proper authentication techniques for a system.« less
MalaCards: an integrated compendium for diseases and their annotation
Rappaport, Noa; Nativ, Noam; Stelzer, Gil; Twik, Michal; Guan-Golan, Yaron; Iny Stein, Tsippi; Bahir, Iris; Belinky, Frida; Morrey, C. Paul; Safran, Marilyn; Lancet, Doron
2013-01-01
Comprehensive disease classification, integration and annotation are crucial for biomedical discovery. At present, disease compilation is incomplete, heterogeneous and often lacking systematic inquiry mechanisms. We introduce MalaCards, an integrated database of human maladies and their annotations, modeled on the architecture and strategy of the GeneCards database of human genes. MalaCards mines and merges 44 data sources to generate a computerized card for each of 16 919 human diseases. Each MalaCard contains disease-specific prioritized annotations, as well as inter-disease connections, empowered by the GeneCards relational database, its searches and GeneDecks set analyses. First, we generate a disease list from 15 ranked sources, using disease-name unification heuristics. Next, we use four schemes to populate MalaCards sections: (i) directly interrogating disease resources, to establish integrated disease names, synonyms, summaries, drugs/therapeutics, clinical features, genetic tests and anatomical context; (ii) searching GeneCards for related publications, and for associated genes with corresponding relevance scores; (iii) analyzing disease-associated gene sets in GeneDecks to yield affiliated pathways, phenotypes, compounds and GO terms, sorted by a composite relevance score and presented with GeneCards links; and (iv) searching within MalaCards itself, e.g. for additional related diseases and anatomical context. The latter forms the basis for the construction of a disease network, based on shared MalaCards annotations, embodying associations based on etiology, clinical features and clinical conditions. This broadly disposed network has a power-law degree distribution, suggesting that this might be an inherent property of such networks. Work in progress includes hierarchical malady classification, ontological mapping and disease set analyses, striving to make MalaCards an even more effective tool for biomedical research. Database URL: http://www.malacards.org/ PMID:23584832
Design and Use of Task Cards in the Reciprocal Style of Teaching
ERIC Educational Resources Information Center
Iserbyt, Peter; Byra, Mark
2013-01-01
Task cards are instructional tools that combine a picture of a skill with written instructions about how to perform the skill. This article provides practical guidelines for developing research-based task cards for use in physical education classes. Fitness-related motor skills are used as examples to clarify design principles for task cards. The…
ERIC Educational Resources Information Center
Duckworth, Angela L.; Quinn, Patrick D.; Tsukayama, Eli
2012-01-01
The increasing prominence of standardized testing to assess student learning motivated the current investigation. We propose that standardized achievement test scores assess competencies determined more by intelligence than by self-control, whereas report card grades assess competencies determined more by self-control than by intelligence. In…
SuperState: a computer program for the control of operant behavioral experimentation.
Zhang, Fuqiang
2006-09-15
Operant behavioral researches require precise control of experimental devices for delivering stimuli and monitoring behavioral responses. The author developed a software solution named SuperState for controlling hardware devices and running reinforcement schedules. The Microsoft Windows compatible software was written by use of an object-oriented programming language Borland Delphi 5.0, which has simplified the programming of the application. SuperState is a stand-alone easy-to-use green software, without the need for the experimenter to master any scripting languages. It features: (1) control of multiple operant cages running independent reinforcement schedules; (2) enough cage devices (16 digital inputs and 16 digital outputs for each cage) suitable for the need of most operant behavioral equipments; (3) control of most standard ISA-type digital interface cards including Med-Associates Super-port cards and a PCI-type card AC6412, and highly expandable to support other PCI-type interface cards; (4) high-resolution device control (1ms); (5) a built-in real-time cumulative recorder; (6) extensive data analyzing including event recorder, cumulative recorder, block analyzing; the summarized results can be transferred easily to Microsoft Excel spreadsheets through the Clipboard.
TACS Central Control Facility.
1981-02-12
PULSE RTC REAL TIME CLOCK -{> I . SIGNAL INVERSION UASC UNIVERSAL ASYNCHRONOUS SERIAL - ---- 4w SPECIAL INTERFACE CONTROLLER Fiq. 2-1. MAC hardware...34 Universal Asynchronous Serial Controller" (UASC) cards. The cards implement an RS-232 standard interface. All controllers are set to operate at a data...Bridwell and I. Richer, "A Preliminary Design of a TDMA System for FLEETSAT," Technical Note 1975-5, Lincoln Laboratory, M.I.T. (12 March 1975), DDC
Slow Controls Using the Axiom M5235BCC
NASA Astrophysics Data System (ADS)
Hague, Tyler
2008-10-01
The Forward Vertex Detector group at PHENIX plans to adopt the Axiom M5235 Business Card Controller for use as slow controls. It is also being evaluated for slow controls on FermiLab e906. This controller features the Freescale MCF5235 microprocessor. It also has three parallel buses, these being the MCU port, BUS port, and enhanced Time Processing Unit (eTPU) port. The BUS port uses a chip select module with three external chip selects to communicate with peripherals. This will be used to communicate with and configure Field Programmable Gate Arrays (FPGAs). The controller also has an Ethernet port which can use several different protocols such as TCP and UDP. This will be used to transfer files with computers on a network. The M5235 Business Card Controller will be placed in a VME crate along with VME card and a Spartan-3 FPGA.
The TOTEM T1 read out card motherboard
NASA Astrophysics Data System (ADS)
Minutoli, S.; Lo Vetere, M.; Robutti, E.
2010-12-01
This article describes the Read Out Card (ROC) motherboard, which is the main component of the T1 forward telescope front-end electronic system. The ROC main objectives are to acquire tracking data and trigger information from the detector. It performs data conversion from electrical to optical format and transfers the data streams to the next level of the system and it implements Slow Control modules which are able to receive, decode and distribute the LHC machine low jitter clock and fast command. The ROC also provides a spy mezzanine connection based on programmable FPGA and USB2.0 for laboratory and portable DAQ debugging system.
Smart Cards and remote entrusting
NASA Astrophysics Data System (ADS)
Aussel, Jean-Daniel; D'Annoville, Jerome; Castillo, Laurent; Durand, Stephane; Fabre, Thierry; Lu, Karen; Ali, Asad
Smart cards are widely used to provide security in end-to-end communication involving servers and a variety of terminals, including mobile handsets or payment terminals. Sometime, end-to-end server to smart card security is not applicable, and smart cards must communicate directly with an application executing on a terminal, like a personal computer, without communicating with a server. In this case, the smart card must somehow trust the terminal application before performing some secure operation it was designed for. This paper presents a novel method to remotely trust a terminal application from the smart card. For terminals such as personal computers, this method is based on an advanced secure device connected through the USB and consisting of a smart card bundled with flash memory. This device, or USB dongle, can be used in the context of remote untrusting to secure portable applications conveyed in the dongle flash memory. White-box cryptography is used to set the secure channel and a mechanism based on thumbprint is described to provide external authentication when session keys need to be renewed. Although not as secure as end-to-end server to smart card security, remote entrusting with smart cards is easy to deploy for mass-market applications and can provide a reasonable level of security.
Introducing Teamwork Challenges in Simulation Using Game Cards.
Chang, Todd P; Kwan, Karen Y; Liberman, Danica; Song, Eric; Dao, Eugene H; Chung, Dayun; Morton, Inge; Festekjian, Ara
2015-08-01
Poor teamwork and communication during resuscitations are linked to patient safety problems and poorer outcomes. We present a novel simulation-based educational intervention using game cards to introduce challenges in teamwork. This intervention uses sets of game cards that designate roles, limitations, or communication challenges designed to introduce common communication or teamwork problems. Game cards are designed to be applicable for any simulation-based scenario and are independent from patient physiology. In our example, participants were pediatric emergency medicine fellows undergoing simulation training for orientation. We describe the use of card sets in different scenarios with increasing teamwork challenge and difficulty. Both postscenario and summative debriefings were facilitated to allow participants to reflect on their performance and discover ways to apply their strategies to real resuscitations. In this article, we present our experience with the novel use of game cards to modify simulation scenarios to improve communication and teamwork skills.
School-based sleep education program improves sleep and academic performance of school-age children.
Gruber, Reut; Somerville, Gail; Bergmame, Lana; Fontil, Laura; Paquin, Soukaina
2016-05-01
The objective of this study was to develop and evaluate the effectiveness of a school-based sleep education program aimed at improving the sleep and academic performance of school-age children. Using a community-based participatory research approach, we created a school-based sleep education program, "Sleep for Success"™ (SFS), composed of four distinct modules that addressed the children, their family and community, the school staff, and decision makers within the school setting. Implementation was carried out in three elementary schools. Seventy-one students participated in the evaluation of the program. The effectiveness of the SFS program was evaluated using non-randomized controlled before-and-after study groups (intervention and control) assessed over two time points (pre- and post-program implementation). Before (baseline) and after implementation, sleep and academic performance were measured using actigraphy and report card marks, respectively. In the intervention group, true sleep was extended by 18.2 min per night, sleep efficiency improved by 2.3%, and sleep latency was shortened by 2.3 min, and report card grades in mathematics and English improved significantly. No changes were noted in the control group. Participation in the sleep education program was associated with significant improvements in children's sleep and academic performance. Copyright © 2016 Elsevier B.V. All rights reserved.
Data-nonintrusive photonics-based credit card verifier with a low false rejection rate.
Sumriddetchkajorn, Sarun; Intaravanne, Yuttana
2010-02-10
We propose and experimentally demonstrate a noninvasive credit card verifier with a low false rejection rate (FRR). Our key idea is based on the use of three broadband light sources in our data-nonintrusive photonics-based credit card verifier structure, where spectral components of the embossed hologram images are registered as red, green, and blue. In this case, nine distinguishable variables are generated for a feed-forward neural network (FFNN). In addition, we investigate the center of mass of the image histogram projected onto the x axis (I(color)), making our system more tolerant of the intensity fluctuation of the light source. We also reduce the unwanted signals on each hologram image by simply dividing the hologram image into three zones and then calculating their corresponding I(color) values for red, green, and blue bands. With our proposed concepts, we implement our field test prototype in which three broadband white light light-emitting diodes (LEDs), a two-dimensional digital color camera, and a four-layer FFNN are used. Based on 249 genuine credit cards and 258 counterfeit credit cards, we find that the average of differences in I(color) values between genuine and counterfeit credit cards is improved by 1.5 times and up to 13.7 times. In this case, we can effectively verify credit cards with a very low FRR of 0.79%.
Evolution of optically nondestructive and data-non-intrusive credit card verifiers
NASA Astrophysics Data System (ADS)
Sumriddetchkajorn, Sarun; Intaravanne, Yuttana
2010-04-01
Since the deployment of the credit card, the number of credit card fraud cases has grown rapidly with a huge amount of loss in millions of US dollars. Instead of asking more information from the credit card's holder or taking risk through payment approval, a nondestructive and data-non-intrusive credit card verifier is highly desirable before transaction begins. In this paper, we review optical techniques that have been proposed and invented in order to make the genuine credit card more distinguishable than the counterfeit credit card. Several optical approaches for the implementation of credit card verifiers are also included. In particular, we highlight our invention on a hyperspectral-imaging based portable credit card verifier structure that offers a very low false error rate of 0.79%. Other key features include low cost, simplicity in design and implementation, no moving part, no need of an additional decoding key, and adaptive learning.
Evaluation and comparison of FTA card and CTAB DNA extraction methods for non-agricultural taxa1
Siegel, Chloe S.; Stevenson, Florence O.; Zimmer, Elizabeth A.
2017-01-01
Premise of the study: An efficient, effective DNA extraction method is necessary for comprehensive analysis of plant genomes. This study analyzed the quality of DNA obtained using paper FTA cards prepared directly in the field when compared to the more traditional cetyltrimethylammonium bromide (CTAB)–based extraction methods from silica-dried samples. Methods: DNA was extracted using FTA cards according to the manufacturer’s protocol. In parallel, CTAB-based extractions were done using the automated AutoGen DNA isolation system. DNA quality for both methods was determined for 15 non-agricultural species collected in situ, by gel separation, spectrophotometry, fluorometry, and successful amplification and sequencing of nuclear and chloroplast gene markers. Results: The FTA card extraction method yielded less concentrated, but also less fragmented samples than the CTAB-based technique. The card-extracted samples provided DNA that could be successfully amplified and sequenced. The FTA cards are also useful because the collected samples do not require refrigeration, extensive laboratory expertise, or as many hazardous chemicals as extractions using the CTAB-based technique. Discussion: The relative success of the FTA card method in our study suggested that this method could be a valuable tool for studies in plant population genetics and conservation biology that may involve screening of hundreds of individual plants. The FTA cards, like the silica gel samples, do not contain plant material capable of propagation, and therefore do not require permits from the U.S. Department of Agriculture (USDA) Animal and Plant Health Inspection Service (APHIS) for transportation. PMID:28224056
Color Coded Cards for Student Behavior Management in Higher Education Environments
ERIC Educational Resources Information Center
Alhalabi, Wadee; Alhalabi, Mobeen
2017-01-01
The Color Coded Cards system as a possibly effective class management tool is the focus of this research. The Color Coded Cards system involves each student being given a card with a specific color based on his or her behavior. The main objective of the research is to find out whether this system effectively improves students' behavior, thus…
Validity Evidence for the Chinese Version Classroom Appraisal of Resources and Demands (CARD)
ERIC Educational Resources Information Center
Zhang, Juan; Wang, Chuang; Lambert, Richard; Wu, Chenggang; Wen, Hongbo
2017-01-01
The Classroom Appraisal of Resources and Demands (CARD) was designed to evaluate teacher stress based on subjective evaluations of classroom demands and resources. However, the CARD has been mostly utilized in western countries. The aim of the current study was to provide aspects of the validity of responses to a Chinese version of the CARD that…
Mohan, Kathleen M; Miller, Joseph M; Harvey, Erin M; Gerhart, Kimberly D; Apple, Howard P; Apple, Deborah; Smith, Jordana M; Davis, Amy L; Leonard-Green, Tina; Campus, Irene; Dennis, Leslie K
2016-01-01
To determine if testing binocular visual acuity in infants and toddlers using the Acuity Card Procedure (ACP) with electronic grating stimuli yields clinically useful data. Participants were infants and toddlers ages 5 to 36.7 months referred by pediatricians due to failed automated vision screening. The ACP was used to test binocular grating acuity. Stimuli were presented on the Dobson Card. The Dobson Card consists of a handheld matte-black plexiglass frame with two flush-mounted tablet computers and is similar in size and form to commercially available printed grating acuity testing stimuli (Teller Acuity Cards II [TACII]; Stereo Optical, Inc., Chicago, IL). On each trial, one tablet displayed a square-wave grating and the other displayed a luminance-matched uniform gray patch. Stimuli were roughly equivalent to the stimuli available in the printed TACII stimuli. After acuity testing, each child received a cycloplegic eye examination. Based on cycloplegic retinoscopy, patients were categorized as having high or low refractive error per American Association for Pediatric Ophthalmology and Strabismus vision screening referral criteria. Mean acuities for high and low refractive error groups were compared using analysis of covariance, controlling for age. Mean visual acuity was significantly poorer in children with high refractive error than in those with low refractive error (P = .015). Electronic stimuli presented using the ACP can yield clinically useful measurements of grating acuity in infants and toddlers. Further research is needed to determine the optimal conditions and procedures for obtaining accurate and clinically useful automated measurements of visual acuity in infants and toddlers. Copyright 2016, SLACK Incorporated.
A Timing Synchronizer System for Beam Test Setups Requiring Galvanic Isolation
NASA Astrophysics Data System (ADS)
Meder, Lukas Dominik; Emschermann, David; Frühauf, Jochen; Müller, Walter F. J.; Becker, Jürgen
2017-07-01
In beam test setups detector elements together with a readout composed of frontend electronics (FEE) and usually a layer of field-programmable gate arrays (FPGAs) are being analyzed. The FEE is in this scenario often directly connected to both the detector and the FPGA layer what in many cases requires sharing the ground potentials of these layers. This setup can become problematic if parts of the detector need to be operated at different high-voltage potentials, since all of the FPGA boards need to receive a common clock and timing reference for getting the readout synchronized. Thus, for the context of the compressed baryonic matter experiment a versatile timing synchronizer (TS) system was designed providing galvanically isolated timing distribution links over twisted-pair cables. As an electrical interface the so-called timing data processing board FPGA mezzanine card was created for being mounted onto FPGA-based advanced mezzanine cards for mTCA.4 crates. The FPGA logic of the TS system connects to this card and can be monitored and controlled through IPBus slow-control links. Evaluations show that the system is capable of stably synchronizing the FPGA boards of a beam test setup being integrated into a hierarchical TS network.
7 CFR 989.158 - Natural condition raisins.
Code of Federal Regulations, 2011 CFR
2011-01-01
... only to raisins which have not been removed from their containers, with pallet control cards still... containing raisins that are wet, or of high moisture content in some areas of the box; (ii) dump raisins from... each pallet a prenumbered RAC control card (to be furnished by the Committee), and kept separate and...
7 CFR 989.158 - Natural condition raisins.
Code of Federal Regulations, 2010 CFR
2010-01-01
... only to raisins which have not been removed from their containers, with pallet control cards still... containing raisins that are wet, or of high moisture content in some areas of the box; (ii) dump raisins from... each pallet a prenumbered RAC control card (to be furnished by the Committee), and kept separate and...
7 CFR 989.158 - Natural condition raisins.
Code of Federal Regulations, 2013 CFR
2013-01-01
... only to raisins which have not been removed from their containers, with pallet control cards still... containing raisins that are wet, or of high moisture content in some areas of the box; (ii) dump raisins from... each pallet a prenumbered RAC control card (to be furnished by the Committee), and kept separate and...
7 CFR 989.158 - Natural condition raisins.
Code of Federal Regulations, 2014 CFR
2014-01-01
... only to raisins which have not been removed from their containers, with pallet control cards still... containing raisins that are wet, or of high moisture content in some areas of the box; (ii) dump raisins from... each pallet a prenumbered RAC control card (to be furnished by the Committee), and kept separate and...
7 CFR 989.158 - Natural condition raisins.
Code of Federal Regulations, 2012 CFR
2012-01-01
... only to raisins which have not been removed from their containers, with pallet control cards still... containing raisins that are wet, or of high moisture content in some areas of the box; (ii) dump raisins from... each pallet a prenumbered RAC control card (to be furnished by the Committee), and kept separate and...
31 CFR 1028.210 - Anti-money laundering programs for operators of credit card systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... minimum, the program must: (1) Incorporate policies, procedures, and internal controls designed to ensure... program reasonably designed to prevent the operator of a credit card system from being used to facilitate... Designated Nationals List issued by Treasury's Office of Foreign Assets Control; (C) A person located in, or...
31 CFR 1028.210 - Anti-money laundering programs for operators of credit card systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... minimum, the program must: (1) Incorporate policies, procedures, and internal controls designed to ensure... program reasonably designed to prevent the operator of a credit card system from being used to facilitate... Designated Nationals List issued by Treasury's Office of Foreign Assets Control; (C) A person located in, or...
31 CFR 1028.210 - Anti-money laundering programs for operators of credit card systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... minimum, the program must: (1) Incorporate policies, procedures, and internal controls designed to ensure... program reasonably designed to prevent the operator of a credit card system from being used to facilitate... Designated Nationals List issued by Treasury's Office of Foreign Assets Control; (C) A person located in, or...
31 CFR 1028.210 - Anti-money laundering programs for operators of credit card systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... minimum, the program must: (1) Incorporate policies, procedures, and internal controls designed to ensure... program reasonably designed to prevent the operator of a credit card system from being used to facilitate... Designated Nationals List issued by Treasury's Office of Foreign Assets Control; (C) A person located in, or...
PROCESS WATER BUILDING, TRA605. CONTROL PANEL SUPPLIES STATUS INDICATORS. CARD ...
PROCESS WATER BUILDING, TRA-605. CONTROL PANEL SUPPLIES STATUS INDICATORS. CARD IN LOWER RIGHT WAS INSERTED BY INL PHOTOGRAPHER TO COVER AN OBSOLETE SECURITY RESTRICTION ON ORIGINAL NEGATIVE. INL NEGATIVE NO. 4219. Unknown Photographer, 2/13/1952 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
77 FR 21420 - Airworthiness Directives; Cessna Aircraft Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-10
.... ACTION: Final rule. SUMMARY: We are adopting a new airworthiness directive (AD) for certain Cessna... fuel control card, due to the cross-feed inputs on the left- and right-hand fuel control cards being connected together and causing an imbalance of fuel between the left and right wing tanks. This AD requires...
Human Factors Assessment and Redesign of the ISS Respiratory Support Pack (RSP) Cue Card
NASA Technical Reports Server (NTRS)
Byrne, Vicky; Hudy, Cynthia; Whitmore, Mihriban; Smith, Danielle
2007-01-01
The Respiratory Support Pack (RSP) is a medical pack onboard the International Space Station (ISS) that contains much of the necessary equipment for providing aid to a conscious or unconscious crewmember in respiratory distress. Inside the RSP lid pocket is a 5.5 by 11 inch paper procedural cue card, which is used by a Crew Medical Officer (CMO) to set up the equipment and deliver oxygen to a crewmember. In training, crewmembers expressed concerns about the readability and usability of the cue card; consequently, updating the cue card was prioritized as an activity to be completed. The Usability Testing and Analysis Facility at the Johnson Space Center (JSC) evaluated the original layout of the cue card, and proposed several new cue card designs based on human factors principles. The approach taken for the assessment was an iterative process. First, in order to completely understand the issues with the RSP cue card, crewmember post training comments regarding the RSP cue card were taken into consideration. Over the course of the iterative process, the procedural information was reorganized into a linear flow after the removal of irrelevant (non-emergency) content. Pictures, color coding, and borders were added to highlight key components in the RSP to aid in quickly identifying those components. There were minimal changes to the actual text content. Three studies were conducted using non-medically trained JSC personnel (total of 34 participants). Non-medically trained personnel participated in order to approximate a scenario of limited CMO exposure to the RSP equipment and training (which can occur six months prior to the mission). In each study, participants were asked to perform two respiratory distress scenarios using one of the cue card designs to simulate resuscitation (using a mannequin along with the hardware). Procedure completion time, errors, and subjective ratings were recorded. The last iteration of the cue card featured a schematic of the RSP, colors, borders, and simplification of the flow of information. The time to complete the RSP procedure was reduced by approximately three minutes with the new design. In an emergency situation, three minutes significantly increases the probability of saving a life. In addition, participants showed the highest preference for this design. The results of the studies and the new design were presented to a focus group of astronauts, flight surgeons, medical trainers, and procedures personnel. The final cue card was presented to a medical control board and approved for flight. The revised RSP cue card is currently onboard ISS.
NPS Government Purchase Card Program: An Analysis of Internal Controls
2014-03-01
approving official APC agency program coordinator CCPMD Consolidated Card Program Management Division CH cardholder COSO Committee of Sponsoring...correct, and minimize fraud, waste, and abuse” (DPAP, 2011, p. 2-2). To minimize risks , the management and internal controls should have support from...three interrelated subjects: enterprise risk management (ERM), internal control, and fraud deterrence” (para. 6). The 23 five components of an
Ridership impacts of South Florida's EASY smart card.
DOT National Transportation Integrated Search
2013-07-01
Smart card-based Automated Fare Collection Systems (AFCS) are being increasingly deployed in transit systems across the US. Miami-Dade Transit (MDT) has recently deployed such a system branded as the EASY Card. The South Florida Regional Transportati...
User`s manual for the CDC-1 digitizer controller
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ferron, J.R.
1994-09-01
A detailed description of how to use the CDC-1 digitizer controller is given. The CDC-1 is used with the CAMAC format digitizer models in the TRAQ series (manufactured by DSP Technology Inc.), the DAD-1 data acquisition daughter board, and the Intel i860-based SuperCard-2 (manufactured, by CSP Inc.) to form a high speed data acquisition and real time analysis system. Data can be transferred to the memory on the SuperCard-2 at a rate as high as 40 million 14-bit samples per second. Depending on the model of TRAQ digitizer in use, digitizing rates up to 3.33 MHz are supported (with eightmore » data channels), or, for instance, at a sample rate of 100 kHz, 384 data channels can be acquired.« less
Camino Willhuber, Gaston Oscar; Guzman Mentesana, Gustavo; Baez, Alejandra; Lo Presti, Silvina; Bazán, Carolina; Strauss, Mariana; Fretes, Ricardo; Paglini-Oliva, Patricia Adriana; Rivarola, Hector Walter
2017-09-08
ResumenIntroducción: la actividad mitocondrial es esencial para el músculo cardíaco y esquelético. La relación entre la disfunción mitocondrial y diferentes condiciones cardiovasculares ha sido bien descrita. El tratamiento farmacológico de la insuficiencia cardíaca implica diferentes medicamentos como: inhibidores de la enzima convertidora de la angiotensina, bloqueadores B-adrenérgicos, glucósidos digitálicos y diuréticos. Los beneficios clínicos del tratamiento son claros, sin embargo, el papel de estos fármacos en el metabolismo mitocondrial no esta bien establecido.Objetivo del estudio: El objetivo de nuestro estudio fue analizar las características estructurales y funcionales de las mitocondrias del músculo cardíaco y esquelético en ratones tratados con fármacos habitualmente utilizados para la insuficiencia cardíaca y compararlo con un grupo control.Métodos: Veinticinco ratones albinos divididos en cinco grupos fueron tratados con la medicación para insuficiencia cardíaca durante 30 días (grupo I a IV). 30 días después del tratamiento se sacrificaron, el corazón y el músculo esquelético se analizaron y se compararon con un grupo control (V).Resultados: La actividad enzimática se incrementó ligeramente en los grupos tratados con medicamentos insuficiencia cardiaca en comparación con el grupo control (p> 0,05). morfología mitocondrial se modificó significativamente en los grupos tratados en comparación con el grupo control, además, el área mitocondrial fue significativamente mayor en los grupos tratados, tanto en el músculo cardíaco y estriado.Conclusiones: Concluimos que la medicación insuficiencia cardíaca podría producir modificaciones en la función mitocondrial; creemos que las mitocondrias pueden mantener la actividad enzimática mediante el aumento de tamaño y modificación de la morfología.
Unconditionally Secure Credit/Debit Card Chip Scheme and Physical Unclonable Function
NASA Astrophysics Data System (ADS)
Kish, Laszlo B.; Entesari, Kamran; Granqvist, Claes-Göran; Kwan, Chiman
The statistical-physics-based Kirchhoff-law-Johnson-noise (KLJN) key exchange offers a new and simple unclonable system for credit/debit card chip authentication and payment. The key exchange, the authentication and the communication are unconditionally secure so that neither mathematics- nor statistics-based attacks are able to crack the scheme. The ohmic connection and the short wiring lengths between the chips in the card and the terminal constitute an ideal setting for the KLJN protocol, and even its simplest versions offer unprecedented security and privacy for credit/debit card chips and applications of physical unclonable functions (PUFs).
Long-term storage and safe retrieval of human papillomavirus DNA using FTA elute cards.
Barth, Heidi; Morel, Adrien; Mougin, Christiane; Averous, Gerlinde; Legrain, Michèle; Fender, Muriel; Risch, Simone; Fafi-Kremer, Samira; Velten, Michel; Oudet, Pierre; Baldauf, Jean-Jacques; Stoll-Keller, Françoise
2016-03-01
Biobanking or collection and storage of specimens for future research purposes have become an essential tool in many fields of biomedical research and aims to provide a better understanding of disease mechanisms as well as the identification of disease-specific biomarkers that can navigate in complex diseases. In this study, we assessed the use of Flinders Technology Associates (FTA) cards as a long-term storage device for cervical specimens with suspected human papillomavirus (HPV) infections. HPV detection and genotyping results in liquid-based transport media were compared to HPV results from FTA cards. The overall agreement for the presence of any HPV infection between liquid-based medium and FTA cards stored for 1 year at ambient temperature was 100%. Reproducibility analysis of HPV detection and genotyping from FTA cards demonstrated that FTA cards are a reliable medium to store and preserve viral nucleic acids. Biobanking of cervical cells on FTA cards may provide a key resource for epidemiological and retrospective HPV studies. Copyright © 2015 Elsevier B.V. All rights reserved.
Liang, Jiajie; Chen, Yongsheng; Xu, Yanfei; Liu, Zhibo; Zhang, Long; Zhao, Xin; Zhang, Xiaoliang; Tian, Jianguo; Huang, Yi; Ma, Yanfeng; Li, Feifei
2010-11-01
Owing to its extraordinary electronic property, chemical stability, and unique two-dimensional nanostructure, graphene is being considered as an ideal material for the highly expected all-carbon-based micro/nanoscale electronics. Herein, we present a simple yet versatile approach to constructing all-carbon micro/nanoelectronics using solution-processing graphene films directly. From these graphene films, various graphene-based microcosmic patterns and structures have been fabricated using maskless computer-controlled laser cutting. Furthermore, a complete system involving a prototype of a flexible write-once-read-many-times memory card and a fast data-reading system has been demonstrated, with infinite data retention time and high reliability. These results indicate that graphene could be the ideal material for fabricating the highly demanded all-carbon and flexible devices and electronics using the simple and efficient roll-to-roll printing process when combined with maskless direct data writing.
Variables Influencing Credit Card Balances of Students at a Midwestern University
ERIC Educational Resources Information Center
Mattson, Lucretia; Sahlhoff, Kathleen; Blackstone, Judith; Peden, Blaine; Nahm, Abraham Y.
2004-01-01
This research used a Web-based survey of students at a Midwest regional university to measure the extent of credit card use by first-year students and seniors. The results indicate that the variables influencing credit card use and the carrying of a balance from one month to the next include the number of cards held by the student, the student's…
Genic insights from integrated human proteomics in GeneCards.
Fishilevich, Simon; Zimmerman, Shahar; Kohn, Asher; Iny Stein, Tsippi; Olender, Tsviya; Kolker, Eugene; Safran, Marilyn; Lancet, Doron
2016-01-01
GeneCards is a one-stop shop for searchable human gene annotations (http://www.genecards.org/). Data are automatically mined from ∼120 sources and presented in an integrated web card for every human gene. We report the application of recent advances in proteomics to enhance gene annotation and classification in GeneCards. First, we constructed the Human Integrated Protein Expression Database (HIPED), a unified database of protein abundance in human tissues, based on the publically available mass spectrometry (MS)-based proteomics sources ProteomicsDB, Multi-Omics Profiling Expression Database, Protein Abundance Across Organisms and The MaxQuant DataBase. The integrated database, residing within GeneCards, compares favourably with its individual sources, covering nearly 90% of human protein-coding genes. For gene annotation and comparisons, we first defined a protein expression vector for each gene, based on normalized abundances in 69 normal human tissues. This vector is portrayed in the GeneCards expression section as a bar graph, allowing visual inspection and comparison. These data are juxtaposed with transcriptome bar graphs. Using the protein expression vectors, we further defined a pairwise metric that helps assess expression-based pairwise proximity. This new metric for finding functional partners complements eight others, including sharing of pathways, gene ontology (GO) terms and domains, implemented in the GeneCards Suite. In parallel, we calculated proteome-based differential expression, highlighting a subset of tissues that overexpress a gene and subserving gene classification. This textual annotation allows users of VarElect, the suite's next-generation phenotyper, to more effectively discover causative disease variants. Finally, we define the protein-RNA expression ratio and correlation as yet another attribute of every gene in each tissue, adding further annotative information. The results constitute a significant enhancement of several GeneCards sections and help promote and organize the genome-wide structural and functional knowledge of the human proteome. Database URL:http://www.genecards.org/. © The Author(s) 2016. Published by Oxford University Press.
A universal computer control system for motors
NASA Technical Reports Server (NTRS)
Szakaly, Zoltan F. (Inventor)
1991-01-01
A control system for a multi-motor system such as a space telerobot, having a remote computational node and a local computational node interconnected with one another by a high speed data link is described. A Universal Computer Control System (UCCS) for the telerobot is located at each node. Each node is provided with a multibus computer system which is characterized by a plurality of processors with all processors being connected to a common bus, and including at least one command processor. The command processor communicates over the bus with a plurality of joint controller cards. A plurality of direct current torque motors, of the type used in telerobot joints and telerobot hand-held controllers, are connected to the controller cards and responds to digital control signals from the command processor. Essential motor operating parameters are sensed by analog sensing circuits and the sensed analog signals are converted to digital signals for storage at the controller cards where such signals can be read during an address read/write cycle of the command processing processor.
Common Badging and Access Control System (CBACS)
NASA Technical Reports Server (NTRS)
Dischinger, Portia
2005-01-01
This slide presentation presents NASA's Common Badging and Access Control System. NASA began a Smart Card implementation in January 2004. Following site surveys, it was determined that NASA's badging and access control systems required upgrades to common infrastructure in order to provide flexibly, usability, and return on investment prior to a smart card implantation. Common Badging and Access Control System (CBACS) provides the common infrastructure from which FIPS-201 compliant processes, systems, and credentials can be developed and used.
Matsuzawa, Daisuke; Shirayama, Yukihiko; Niitsu, Tomihisa; Hashimoto, Kenji; Iyo, Masaomi
2015-03-03
Defective decision-making is a symptom of impaired cognitive function observed in patients with schizophrenia. Impairment on the Iowa Gambling Task (IGT) has been reported in patients with schizophrenia, but these results are inconsistent among studies. We differentiated subjects based on whether they expressed certainty at having deciphered an advantageous strategy in the course of the task. We investigated this impairment using the IGT in patients with schizophrenia and performed analysis different to standard advantageous decks minus disadvantageous decks in all 100 card choices, [C+D]-[A+B](1-100). We examined the effects on behavior after receiving a big penalty. Results were dependent on participants utilizing with or without certainty, the best strategy for positive gain. Schizophrenic patients without certainty failed to show card choice shift, from disadvantageous to advantageous decks. Differences in card choices on the IGT were clearly shown between patients with schizophrenia and normal controls by the use of improvement from block 1 to blocks 3-5, [C+D]-[A+B]([41-100]-[1-20]) (P<0.001), rather than by the composite value of blocks 3-5, [C+D]-[A+B](41-100) (P=0.011). The deficit of emotion-based learning in schizophrenia without uncertainty were related to scores on the SANS and S5 attention. In addition, S1 affective flattering and S4 anhedonia-asociality were also related to these deficits. For a while, normal controls showed a smooth shift from disadvantageous to advantageous decks after big penalties, with or without a certainty for strategy. However, patients with schizophrenia failed to show switching from disadvantageous to advantageous decks, even after big penalties, under the same conditions. Our results highlight certainty of strategy and behavior after a big penalty, as two points of difference between patients with schizophrenia and normal controls in the accumulation of net scores. Copyright © 2014 Elsevier Inc. All rights reserved.
Boo! Outsourcing from the Cataloging Perspective.
ERIC Educational Resources Information Center
Hill, Janet Swan
1998-01-01
Examines long-accepted ways library cataloging departments have used outsourcing (cataloging records, card production, authority control, card filling, and retrospective conversion) and potential outsourcing activities (original cataloging, and copy cataloging). Discusses reasons why outsourcing is controversial. (PEN)
Optical smart card using semipassive communication.
Glaser, I; Green, Shlomo; Dimkov, Ilan
2006-03-15
An optical secure short-range communication system is presented. The mobile unit (optical smart card) of this system utilizes a retroreflector with an optical modulator, using light from the stationary unit; this mobile unit has very low power consumption and can be as small as a credit card. Such optical smart cards offer better security than RF-based solutions, yet do not require physical contact. Results from a feasibility study model are included.
Optical smart card using semipassive communication
NASA Astrophysics Data System (ADS)
Glaser, I.; Green, Shlomo; Dimkov, Ilan
2006-03-01
An optical secure short-range communication system is presented. The mobile unit (optical smart card) of this system utilizes a retroreflector with an optical modulator, using light from the stationary unit; this mobile unit has very low power consumption and can be as small as a credit card. Such optical smart cards offer better security than RF-based solutions, yet do not require physical contact. Results from a feasibility study model are included.
Department of the Navy Acquisition and Capabilities Guidebook
2012-05-01
Cost Estimates/Service Cost Position..................................... 5-1 5.1.2 Cost Analysis Requirements Description ( CARD ) 5-2 5.1.3...Description ( CARD ). 7. Satisfactory review of program health. 8. Concurrence with draft TDS, TES, and SEP. 9. Approval of full funding...Description ( CARD ) SECNAV M-5000.2 May 2012 5-3 Enclosure (1) A sound cost estimate is based on a well-defined program. The CARD is used
Smartcards in Libraries: A Brave New World.
ERIC Educational Resources Information Center
Myhill, Martin
1998-01-01
Describes the University of Exeter (UK), Mondex, and NatWest UK smartcard-based campus card system project. Smartcards, wallet-sized plastic cards with microprocessors, interface with network terminal devices and are programmable as data, identity, and finance cards. International standard multiple operating system (MULTOS) increases current…
Leshchiner, Elizaveta S; Rush, Jason S; Durney, Michael A; Cao, Zhifang; Dančík, Vlado; Chittick, Benjamin; Wu, Huixian; Petrone, Adam; Bittker, Joshua A; Phillips, Andrew; Perez, Jose R; Shamji, Alykhan F; Kaushik, Virendar K; Daly, Mark J; Graham, Daniel B; Schreiber, Stuart L; Xavier, Ramnik J
2017-10-24
Advances in human genetics have dramatically expanded our understanding of complex heritable diseases. Genome-wide association studies have identified an allelic series of CARD9 variants associated with increased risk of or protection from inflammatory bowel disease (IBD). The predisposing variant of CARD9 is associated with increased NF-κB-mediated cytokine production. Conversely, the protective variant lacks a functional C-terminal domain and is unable to recruit the E3 ubiquitin ligase TRIM62. Here, we used biochemical insights into CARD9 variant proteins to create a blueprint for IBD therapeutics and recapitulated the mechanism of the CARD9 protective variant using small molecules. We developed a multiplexed bead-based technology to screen compounds for disruption of the CARD9-TRIM62 interaction. We identified compounds that directly and selectively bind CARD9, disrupt TRIM62 recruitment, inhibit TRIM62-mediated ubiquitinylation of CARD9, and demonstrate cellular activity and selectivity in CARD9-dependent pathways. Taken together, small molecules targeting CARD9 illustrate a path toward improved IBD therapeutics. Published under the PNAS license.
[Groupamatic 360 C1 and automated blood donor processing in a transfusion center].
Guimbretiere, J; Toscer, M; Harousseau, H
1978-03-01
Automation of donor management flow path is controlled by: --a 3 slip "port a punch" card, --the groupamatic unit with a result sorted out on punch paper tape, --the management computer off line connected to groupamatic. Data tracking at blood collection time is made by punching a card with the donor card used as a master card. Groupamatic performs: --a standard blood grouping with one run for registered donors and two runs for new donors, --a phenotyping with two runs, --a screening of irregular antibodies. Themanagement computer checks the correlation between the data of the two runs or the data of a single run and that of previous file. It updates the data resident in the central file and prints out: --the controls of the different blood group for the red cell panel, --The listing of error messages, --The listing of emergency call up, --The listing of collected blood units when arrived at the blood center, with quantitative and qualitative information such as: number of blood, units collected, donor addresses, etc., --Statistics, --Donor cards, --Diplomas.
Fabrication of Cantilever-Bump Type Si Probe Card
NASA Astrophysics Data System (ADS)
Park, Jeong-Yong; Lee, Dong-Seok; Kim, Dong-Kwon; Lee, Jong-Hyun
2000-12-01
Probe card is most important part in the test system which selects the good or bad chip of integrated circuit (IC) chips. Silicon vertical probe card is able to test multiple semiconductor chips simultaneously. We presented cantilever-bump type vertical probe card. It was fabricated by dry etching using RIE(reactive ion etching) technique and porous silicon micromachining using silicon direct bonded (SDB) wafer. Cantilevers and bumps were fabricated by isotropic etching using RIE@. 3-dimensional structures were formed by porous silicon micromachining technique using SDB wafer. Contact resistance of fabricated probe card was less than 2 Ω and its life time was more than 200,000 turns. The process used in this work is very simple and reproducible, which has good controllability in the tip dimension and spacing. It is expected that the fabricated probe card can reduce testing time, can promote productivity and enables burn-in test.
The role of optics in secure credentials
NASA Astrophysics Data System (ADS)
Lichtenstein, Terri L.
2006-02-01
The global need for secure ID credentials has grown rapidly over the last few years. This is evident both in government and commercial sectors. Governmental programs include national ID card programs, permanent resident cards for noncitizens, biometric visas or border crossing cards, foreign worker ID programs and secure vehicle registration programs. The commercial need for secure credentials includes secure banking and financial services, security and access control systems and digital healthcare record cards. All of these programs necessitate the use of multiple tamper and counterfeit resistant features for credential authentication and cardholder verification. It is generally accepted that a secure credential should include a combination of overt, covert and forensic security features. The LaserCard optical memory card is a proven example of a secure credential that uses a variety of optical features to enhance its counterfeit resistance and reliability. This paper will review those features and how they interact to create a better credential.
NASA Technical Reports Server (NTRS)
Cecil, R. W.; White, R. A.; Szczur, M. R.
1972-01-01
The IDAMS Processor is a package of task routines and support software that performs convolution filtering, image expansion, fast Fourier transformation, and other operations on a digital image tape. A unique task control card for that program, together with any necessary parameter cards, selects each processing technique to be applied to the input image. A variable number of tasks can be selected for execution by including the proper task and parameter cards in the input deck. An executive maintains control of the run; it initiates execution of each task in turn and handles any necessary error processing.
Augmented reality application utility for aviation maintenance work instruction
NASA Astrophysics Data System (ADS)
Pourcho, John Bryan
Current aviation maintenance work instructions do not display information effectively enough to prevent costly errors and safety concerns. Aircraft are complex assemblies of highly interrelated components that confound troubleshooting and can make the maintenance procedure difficult (Drury & Gramopadhye, 2001). The sophisticated nature of aircraft maintenance necessitates a revolutionized training intervention for aviation maintenance technicians (United States General Accounting Office, 2003). Quite simply, the paper based job task cards fall short of offering rapid access to technical data and the system or component visualization necessary for working on complex integrated aircraft systems. Possible solutions to this problem include upgraded standards for paper based task cards and the use of integrated 3D product definition used on various mobile platforms (Ropp, Thomas, Lee, Broyles, Lewin, Andreychek, & Nicol, 2013). Previous studies have shown that incorporation of 3D graphics in work instructions allow the user to more efficiently and accurately interpret maintenance information (Jackson & Batstone, 2008). For aircraft maintenance workers, the use of mobile 3D model-based task cards could make current paper task card standards obsolete with their ability to deliver relevant, synchronized information to and from the hangar. Unlike previous versions of 3D model-based definition task cards and paper task cards, which are currently used in the maintenance industry, 3D model based definition task cards have the potential to be more mobile and accessible. Utilizing augmented reality applications on mobile devices to seamlessly deliver 3D product definition on mobile devices could increase the efficiency, accuracy, and reduce the mental workload for technicians when performing maintenance tasks (Macchiarella, 2004). This proposal will serve as a literary review of the aviation maintenance industry, the spatial ability of maintenance technicians, and benefits of modern digital hardware to educate, point out gaps in research, and observe possible foundations on which to build the future of aviation maintenance job task cards leading to a the methodology of the proposed study.
Trial of a "credit card" asthma self-management plan in a high-risk group of patients with asthma.
D'Souza, W; Burgess, C; Ayson, M; Crane, J; Pearce, N; Beasley, R
1996-05-01
The "credit card" asthma self-management plan provides the adult asthmatic patient with simple guidelines for the self-management of asthma, which are based on the self-assessment of peak expiratory flow rate recordings and symptoms. The study was a trial of the clinical efficacy of the credit card plan in a high-risk group of asthmatic patients. In this "before-and-after" trial, patients discharged from the emergency department of Wellington Hospital, after treatment for severe asthma were invited to attend a series of hospital outpatient clinics at which the credit card plan was introduced. Questionnaires were used to compare markers of asthma morbidity, requirement for emergency medical care, and medication use during the 6-month period before and after intervention with the credit card plan. Of the 30 patients with asthma who attended the first outpatient clinic, 26 (17 women and 9 men) completed the program. In these 26 participants, there was a reduction in both morbidity and requirement for acute medical services: specifically, the proportion waking with asthma more than once a week decreased from 65% to 23% (p = 0.005) and the proportion visiting the emergency department for treatment of severe asthma decreased from 58% to 15% (p = 0.004). The patients attending the clinics commented favorably on the plan, in particular on its usefulness as an educational tool for monitoring and treating their asthma. Although the interpretation of this study is limited by the lack of a randomized control group, the findings are consistent with other evidence that the credit card asthma self-management plan can be an effective and acceptable system for improving asthma care in a high-risk group of adult patients with asthma.
Application of an artificial neural network to pump card diagnosis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ashenayi, K.; Lea, J.F.; Kemp, F.
1994-12-01
Beam pumping is the most frequently used artificial-lift technique for oil production. Downhole pump cards are used to evaluate performance of the pumping unit. Pump cards can be generated from surface dynamometer cards using a 1D wave equation with viscous damping, as suggested by Gibbs and Neely. Pump cards contain significant information describing the behavior of the pump. However, interpretation of these cards is tedious and time-consuming; hence, an automated system capable of interpreting these cards could speed interpretation and warn of pump failures. This work presents the results of a DOS-based computer program capable of correctly classifying pump cards.more » The program uses a hybrid artificial neural network (ANN) to identify significant features of the pump card. The hybrid ANN uses classical and sinusoidal perceptrons. The network is trained using an error-back-propagation technique. The program correctly identified pump problems for more than 180 different training and test pump cards. The ANN takes a total of 80 data points as input. Sixty data points are collected from the pump card perimeter, and the remaining 20 data points represent the slope at selected points on the pump card perimeter. Pump problem conditions are grouped into 11 distinct classes. The network is capable of identifying one or more of these problem conditions for each pump card. Eight examples are presented and discussed.« less
Applications of a sugar-based surveillance system to track arboviruses in wild mosquito populations.
van den Hurk, Andrew F; Hall-Mendelin, Sonja; Townsend, Michael; Kurucz, Nina; Edwards, Jim; Ehlers, Gerhard; Rodwell, Chris; Moore, Frederick A; McMahon, Jamie L; Northill, Judith A; Simmons, Russell J; Cortis, Giles; Melville, Lorna; Whelan, Peter I; Ritchie, Scott A
2014-01-01
Effective arbovirus surveillance is essential to ensure the implementation of control strategies, such as mosquito suppression, vaccination, or dissemination of public warnings. Traditional strategies employed for arbovirus surveillance, such as detection of virus or virus-specific antibodies in sentinel animals, or detection of virus in hematophagous arthropods, have limitations as an early-warning system. A system was recently developed that involves collecting mosquitoes in CO2-baited traps, where the insects expectorate virus on sugar-baited nucleic acid preservation cards. The cards are then submitted for virus detection using molecular assays. We report the application of this system for detecting flaviviruses and alphaviruses in wild mosquito populations in northern Australia. This study was the first to employ nonpowered passive box traps (PBTs) that were designed to house cards baited with honey as the sugar source. Overall, 20/144 (13.9%) of PBTs from different weeks contained at least one virus-positive card. West Nile virus Kunjin subtype (WNVKUN), Ross River virus (RRV), and Barmah Forest virus (BFV) were detected, being identified in 13/20, 5/20, and 2/20 of positive PBTs, respectively. Importantly, sentinel chickens deployed to detect flavivirus activity did not seroconvert at two Northern Territory sites where four PBTs yielded WNVKUN. Sufficient WNVKUN and RRV RNA was expectorated onto some of the honey-soaked cards to provide a template for gene sequencing, enhancing the utility of the sugar-bait surveillance system for investigating the ecology, emergence, and movement of arboviruses.
Flexible Peripheral Component Interconnect Input/Output Card
NASA Technical Reports Server (NTRS)
Bigelow, Kirk K.; Jerry, Albert L.; Baricio, Alisha G.; Cummings, Jon K.
2010-01-01
The Flexible Peripheral Component Interconnect (PCI) Input/Output (I/O) Card is an innovative circuit board that provides functionality to interface between a variety of devices. It supports user-defined interrupts for interface synchronization, tracks system faults and failures, and includes checksum and parity evaluation of interface data. The card supports up to 16 channels of high-speed, half-duplex, low-voltage digital signaling (LVDS) serial data, and can interface combinations of serial and parallel devices. Placement of a processor within the field programmable gate array (FPGA) controls an embedded application with links to host memory over its PCI bus. The FPGA also provides protocol stacking and quick digital signal processor (DSP) functions to improve host performance. Hardware timers, counters, state machines, and other glue logic support interface communications. The Flexible PCI I/O Card provides an interface for a variety of dissimilar computer systems, featuring direct memory access functionality. The card has the following attributes: 8/16/32-bit, 33-MHz PCI r2.2 compliance, Configurable for universal 3.3V/5V interface slots, PCI interface based on PLX Technology's PCI9056 ASIC, General-use 512K 16 SDRAM memory, General-use 1M 16 Flash memory, FPGA with 3K to 56K logical cells with embedded 27K to 198K bits RAM, I/O interface: 32-channel LVDS differential transceivers configured in eight, 4-bit banks; signaling rates to 200 MHz per channel, Common SCSI-3, 68-pin interface connector.
Di Pasquale, Giuseppe; Mathieu, Giovanni; Maggioni, Aldo Pietro; Fabbri, Gianna; Lucci, Donata; Vescovo, Giorgio; Pirelli, Salvatore; Chiarella, Francesco; Scherillo, Marino; Gulizia, Michele Massimo; Gussoni, Gualberto; Colombo, Fabrizio; Panuccio, Domenico; Nozzoli, Carlo; Berisso, Massimo Zoni
2013-09-10
Atrial fibrillation (AF) is associated with a high risk of stroke and mortality. To describe the difference in AF management of patients (pts) referred to Cardiology (CARD) or Internal Medicine (MED) units in Italy. From May to July 2010, 360 centers enrolled 7148 pts (54% in CARD and 46% in MED). Median age was 77 years (IQR 70-83). Hypertension was the most prevalent associated condition, followed by hypercholesterolemia (28.9%), heart failure (27.7%) and diabetes (24.3%). MED pts were older, more frequently females and more often with comorbidities than CARD pts. In the 4845 pts with nonvalvular AF, a CHADS2 score ≥ 2 was present in 53.0% of CARD vs 75.3% of MED pts (p<.0001). Oral anticoagulants (OAC) were prescribed in 64.2% of CARD vs 46.3% of MED pts (p<.0001); OAC prescription rate was 49.6% in CHADS2 0 and 56.2% in CHADS2 score ≥ 2 pts. At the adjusted analysis patients managed in MED had a significantly lower probability to be treated with OAC. Rate control strategy was pursued in 51.4% of the pts (60.5% in MED and 43.6% in CARD) while rhythm control was the choice in 39.8% of CARD vs 12.9% of MED pts (p<.0001). Cardiologists and internists seem to manage pts with large epidemiological differences. Both CARD and MED specialists currently fail to prescribe OAC in accordance with stroke risk. Patients managed by MED specialists have a lower probability to receive an OAC treatment, irrespective of the severity of clinical conditions. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Buccal DNA collection: comparison of buccal swabs with FTA cards.
Milne, Elizabeth; van Bockxmeer, Frank M; Robertson, Laila; Brisbane, Joanna M; Ashton, Lesley J; Scott, Rodney J; Armstrong, Bruce K
2006-04-01
Collection and analysis of DNA, most commonly from blood or buccal cells, is becoming more common in epidemiologic studies. Buccal samples, which are painless to take and relatively easily collected, are often the preferred source. There are several buccal cell collection methods: swabs, brushes, mouthwash, and treated cards, such as FTA or IsoCode cards. Few studies have systematically compared methods of buccal cell collection with respect to DNA yield and amplification success under similar conditions. We compared buccal DNA collection and amplification using buccal swabs and FTA cards in 122 control subjects from our Australian case-control study of childhood acute lymphoblastic leukaemia. Buccal DNA was quantified using a real-time PCR for beta-actin and genotyped at the loci of three polymorphisms (MTHFR 677C>T, ACE I/D, and XPD 1012G>A). PCR was successful with DNA from buccal swabs for 62% to 89% of subjects and from FTA cards for 83% to 100% of subjects, depending on the locus. The matched pair odds ratios (95% confidence interval) comparing success of FTA cards with buccal swabs are as follows: MTHFR 677C>T using PCR-RFLP, 12.5 (11.6-13.5) and using real-time PCR, 130.0 (113.1-152.8); ACE I/D using PCR-amplified fragment length polymorphism, 3.36 (3.2-3.5); XPD 1012G>A using real-time PCR, 150.0 (132.7-172.3). FTA cards are a robust DNA collection method and generally produce DNA suitable for PCR more reliably than buccal swabs. There are, however, technical challenges in handling discs punched from FTA cards that intending users should be aware of.
Lee, Sung Won; Lee, Shin Seok; Oh, Dong Ho; Park, Dong Jin; Kim, Hyun Sook; Choi, Jung Ran; Chae, Soo Cheon; Yun, Ki Jung; Chung, Won Tae; Choe, Jung Yoon; Kim, Seong Kyu
2016-10-01
The aim of this study was to determine the association between P2X7R rs3751142 and CARD8 rs2043211 polymorphisms and gout susceptibility in male Korean subjects. This study enrolled a total of 242 male patients with gout and 280 healthy controls. The polymorphisms of two individual genes including rs3751142(C>A) in the P2X7R gene and rs2043211(A>T) in the CARD8 gene were assessed using Taq-Man analysis. Statistical analyses were performed using the Chi-square test, Kruskal-Wallis test, and logistic regression analyses. A difference in genotypic frequency of the P2X7R rs3751142 and CARD8 rs2043211 genes was not detected between gout and control patients. Clinical parameters including age, onset age, disease duration, body mass index, and serum uric acid levels were not different among the three genotypes for either P2X7R or CARD8 (P > 0.05 for all). A pair-wise comparison of P2X7R rs3751142 and CARD8 rs2043211 genotype combinations revealed that subjects with the CA P2X7R rs3751142 genotype and the TT CARD8 rs2043211 genotype had a trend toward a higher risk of gout compared to the CC/AA combination (P = 0.056, OR = 2.618, 95% CI 0.975 - 7.031). In conclusion, this study revealed that genetic variability of the P2X7R rs3751142 and CARD8 rs2043211 genes might, in part, be associated with susceptibility for gout.
Burkhalter, Kristen L; Wiggins, Keenan; Burkett-Cadena, Nathan; Alto, Barry W
2018-05-04
Commercially available assays utilizing antigen or nucleic acid detection chemistries provide options for mosquito control districts to screen their mosquito populations for arboviruses and make timely operational decisions regarding vector control. These assays may be utilized even more advantageously when combined with honey-soaked nucleic acid preservation substrate ('honey card') testing by reducing or replacing the time- and labor-intensive efforts of identifying and processing mosquito pools. We tested artificially inoculated honey cards and cards fed upon individually by West Nile virus (WNV) and Zika virus (ZIKV)-infected mosquitoes with three assays to compare detection rates and the limit of detection for each platform with respect to virus detection of a single infected mosquito and quantify the time interval of virus preservation on the cards. Assays evaluated included CDC protocols for real-time reverse transcriptase polymerase chain reaction (RT-PCR) for WNV and ZIKV, Pro-Lab Diagnostics ProAmpRT WNV loop-mediated amplification (LAMP) and ZIKV LAMP assays, and the Rapid Analyte Measurement Platform (RAMP) WNV assay. Real-time RT-PCR was the most sensitive assay and the most robust to viral RNA degradation over time. To maximize the detection of virus, honey cards should be left in the traps ≤1 d if using LAMP assays and ≤3 d if using real-time RT-PCR to detect viruses from field samples. The WNV RAMP assay, although effective for pool screening, lacks sensitivity required for honey card surveillance. Future studies may determine the minimum number of infectious mosquitoes required to feed on a honey card that would be reliably detected by the LAMP or RAMP assays.
Wang, Shao-Ming; Hu, Shang-Ying; Chen, Wen; Chen, Feng; Zhao, Fang-Hui; He, Wei; Ma, Xin-Ming; Zhang, Yu-Qing; Wang, Jian; Sivasubramaniam, Priya; Qiao, You-Lin
2015-11-04
Liquid-state specimen carriers are inadequate for sample transportation in large-scale screening projects in low-resource settings, which necessitates the exploration of novel non-hazardous solid-state alternatives. Studies investigating the feasibility and accuracy of a solid-state human papillomavirus (HPV) sampling medium in combination with different down-stream HPV DNA assays for cervical cancer screening are needed. We collected two cervical specimens from 396 women, aged 25-65 years, who were enrolled in a cervical cancer screening trial. One sample was stored using DCM preservative solution and the other was applied to a Whatman Indicating FTA Elute® card (FTA card). All specimens were processed using three HPV testing methods, including Hybrid capture 2 (HC2), careHPV™, and Cobas®4800 tests. All the women underwent a rigorous colposcopic evaluation that included using a microbiopsy protocol. Compared to the liquid-based carrier, the FTA card demonstrated comparable sensitivity for detecting high grade Cervical Intraepithelial Neoplasia (CIN) using HC2 (91.7 %), careHPV™ (83.3 %), and Cobas®4800 (91.7 %) tests. Moreover, the FTA card showed a higher specificity compared to a liquid-based carrier for HC2 (79.5 % vs. 71.6 %, P = 0.015), comparable specificity for careHPV™ (78.1 % vs. 73.0 %, P > 0.05), but lower specificity for the Cobas®4800 test (62.4 % vs. 69.9 %, P = 0.032). Generally, the FTA card-based sampling medium's accuracy was comparable with that of liquid-based medium for the three HPV testing assays. FTA cards are a promising sample carrier for cervical cancer screening. With further optimization, it can be utilized for HPV testing in areas of varying economic development.
Community-based asthma care: trial of a "credit card" asthma self-management plan.
D'Souza, W; Crane, J; Burgess, C; Te Karu, H; Fox, C; Harper, M; Robson, B; Howden-Chapman, P; Crossland, L; Woodman, K
1994-07-01
Although asthma self-management plans are widely recommended as essential in the long-term treatment of adult asthma, there have been few studies examining their use. Our objective was to assess the effect of a "credit card" adult asthma self-management plan in a community experiencing major health problems from asthma, by means of a before and after intervention trial of the efficacy of the "credit card" plan, when introduced through community-based asthma clinics. The participants were 69 Maori people with asthma. The "credit card" plan consisted of written guidelines for the self-management of asthma, based on self-assessment of asthma severity, printed on a plastic card. On one side, management guidelines were based on the interpretation of peak expiratory flow rate (PEFR) recordings, whilst the reverse side was based on symptoms. The outcome measures used were before and after comparison of markers of asthma morbidity and requirement for acute medical treatment; and a structured questionnaire assessing the acceptability and use of the credit card plan. Following the introduction of the plan, the mean PEFR increased from 347 to 389 l.min-1, the percentage of nights woken fell from 30.4 to 16.9%, and the number of days "out of action" fell from 3.8 to 1.7%. The requirements for acute medical treatment also fell during the intervention period. Most participants commented favourably on the content and usefulness of the plan. In the situation of worsening asthma, 28% of subjects found the peak flow side of the card most helpful, 7% the symptoms side, and 48% found both sides equally helpful.(ABSTRACT TRUNCATED AT 250 WORDS)
IR Cards: Inquiry-Based Introduction to Infrared Spectroscopy
ERIC Educational Resources Information Center
Bennett, Jacqueline; Forster, Tabetha
2010-01-01
As infrared spectroscopy (IR) is frequently used in undergraduate organic chemistry courses, an inductive introduction to IR spectroscopy that uses index cards printed with spectra, structures, and chemical names is described. Groups of students are given an alphabetized deck of these "IR cards" to sort into functional groups. The students then…
ERIC Educational Resources Information Center
Zullo, Holly S.
2011-01-01
Card tricks based on mathematical principles can be a great way to get students interested in exploring some important mathematical ideas. In this article, the author discusses a simple spreadsheet implementation that shows students why the card trick works and allows them to explore several variations. As an added bonus, students are introduced…
12 CFR 226.59 - Reevaluation of rate increases.
Code of Federal Regulations, 2014 CFR
2014-01-01
... SYSTEM (CONTINUED) TRUTH IN LENDING (REGULATION Z) Special Rules Applicable to Credit Card Accounts and... to a credit card account under an open-end (not home-secured) consumer credit plan, based on the... new credit card accounts under an open-end (not home-secured) consumer credit plan. (2) Rate increases...
12 CFR 226.59 - Reevaluation of rate increases.
Code of Federal Regulations, 2013 CFR
2013-01-01
... SYSTEM (CONTINUED) TRUTH IN LENDING (REGULATION Z) Special Rules Applicable to Credit Card Accounts and... to a credit card account under an open-end (not home-secured) consumer credit plan, based on the... new credit card accounts under an open-end (not home-secured) consumer credit plan. (2) Rate increases...
Post-Attack Economic Stabilization Issues for Federal, State, and Local Governments
1985-02-01
workers being transfered from large urban areas to production facilities in areas of lower risk . In another case, rent control staff should be quickly...food supermarkets , which do not universally accept bank cards. 3 0 A requirement will still exist for a large number of credit cards. While there is some...separate system is required for rationing. For example, the increasingly popular automatic teller machine ( ATM ) debit card routinely accesses both a
Martin, J E; Rusch, F R; James, V L; Decker, P J; Trtol, K A
1982-01-01
This investigation examined the effectiveness of picture cues in establishing self-control in the completion of complex meals by mildly and moderately retarded adults. Three participants, who lived in nonsheltered residential settings, were trained to prepare five complex meals. Following a training baseline comprised of pre-instruction, instructional feedback, and trainers' presence, picture recipe cards were introduced in a multiple-baseline fashion. Rapid improvement in the ability of each participant to independently complete each meal when the picture recipe cards were used occurred. A return to baseline for one of the participants demonstrated further self-directed antecedent stimulus control of the picture recipe cards as an effective treatment procedure. A discussion of future areas of research is included.
The research of laser marking control technology
NASA Astrophysics Data System (ADS)
Zhang, Qiue; Zhang, Rong
2009-08-01
In the area of Laser marking, the general control method is insert control card to computer's mother board, it can not support hot swap, it is difficult to assemble or it. Moreover, the one marking system must to equip one computer. In the system marking, the computer can not to do the other things except to transmit marking digital information. Otherwise it can affect marking precision. Based on traditional control methods existed some problems, introduced marking graphic editing and digital processing by the computer finish, high-speed digital signal processor (DSP) control marking the whole process. The laser marking controller is mainly contain DSP2812, digital memorizer, DAC (digital analog converting) transform unit circuit, USB interface control circuit, man-machine interface circuit, and other logic control circuit. Download the marking information which is processed by computer to U disk, DSP read the information by USB interface on time, then processing it, adopt the DSP inter timer control the marking time sequence, output the scanner control signal by D/A parts. Apply the technology can realize marking offline, thereby reduce the product cost, increase the product efficiency. The system have good effect in actual unit markings, the marking speed is more quickly than PCI control card to 20 percent. It has application value in practicality.
Dong, Li; Lin, Chunqing; Li, Li; Wang, Margaret; Cui, Jianfeng; Feng, Ruimei; Liu, Bin; Wu, Zeni; Lian, Jia; Liao, Guangdong; Chen, Wen; Qiao, Youlin
2017-09-01
Effective dry storage and transport media as an alternative to conventional liquid-based medium would facilitate the accessibility of women in the low-resource settings to human papillomavirus (HPV)- based cervical cancer screening. To evaluate analytical and clinical performance of indicating FTA™ Elute Cartridge (FTA card) for the detection of HPV16/18 and cervical precancerous lesions and cancer compared to dry swab and liquid medium. Ninety patients with abnormal cytology and/or HPV infection were included for analysis. Three specimens of cervical exfoliated cells from each woman were randomly collected by FTA card, dry swab or liquid-based medium prior to colposcopy examination. The subsequent HPV DNA tests were performed on cobas 4800 HPV platform. High-risk HPV (hrHPV) positivity rate was 63.3%, 62.2% and 65.6% for samples collected by FTA card, dry swab and liquid medium, respectively. The overall agreements and kappa values for the detection of hrHPV, HPV 16 and HPV 18 between FTA card and liquid-based medium were 88.9% (κ=0.76), 97.8% (κ=0.94) and 100% (κ=1.0),respectively; between FTA card and dry swab were 92.1% (κ=0.83), 94.5% (κ=0.87) and 100% (κ=1.0), respectively. The performances of hrHPV tested by FTA card, dry swab, and liquid-based medium for detecting CIN2+ were comparable in terms of the sensitivity and specificity. The specificity of detection of CIN2+ by HPV16/18 increased by approximately 40% compared to hrHPV for any medium albeit at cost of a moderate loss of sensitivity. Dry medium might offer an alternative to conventional liquid-based medium in the HPV-based cervical cancer screening program especially in low-resource settings but still needs further evaluation. Copyright © 2017. Published by Elsevier B.V.
Is poker a game of skill or chance? A quasi-experimental study.
Meyer, Gerhard; von Meduna, Marc; Brosowski, Tim; Hayer, Tobias
2013-09-01
Due to intensive marketing and the rapid growth of online gambling, poker currently enjoys great popularity among large sections of the population. Although poker is legally a game of chance in most countries, some (particularly operators of private poker web sites) argue that it should be regarded as a game of skill or sport because the outcome of the game primarily depends on individual aptitude and skill. The available findings indicate that skill plays a meaningful role; however, serious methodological weaknesses and the absence of reliable information regarding the relative importance of chance and skill considerably limit the validity of extant research. Adopting a quasi-experimental approach, the present study examined the extent to which the influence of poker playing skill was more important than card distribution. Three average players and three experts sat down at a six-player table and played 60 computer-based hands of the poker variant "Texas Hold'em" for money. In each hand, one of the average players and one expert received (a) better-than-average cards (winner's box), (b) average cards (neutral box) and (c) worse-than-average cards (loser's box). The standardized manipulation of the card distribution controlled the factor of chance to determine differences in performance between the average and expert groups. Overall, 150 individuals participated in a "fixed-limit" game variant, and 150 individuals participated in a "no-limit" game variant. ANOVA results showed that experts did not outperform average players in terms of final cash balance. Rather, card distribution was the decisive factor for successful poker playing. However, expert players were better able to minimize losses when confronted with disadvantageous conditions (i.e., worse-than-average cards). No significant differences were observed between the game variants. Furthermore, supplementary analyses confirm differential game-related actions dependent on the card distribution, player status, and game variant. In conclusion, the study findings indicate that poker should be regarded as a game of chance, at least under certain basic conditions, and suggest new directions for further research.
Internet Delivered Support for Tobacco Control in Dental Practice: Randomized Controlled Trial
Richman, Joshua S; Ray, Midge N; Allison, Jeroan J; Gilbert, Gregg H; Shewchuk, Richard M; Kohler, Connie L; Kiefe, Catarina I
2008-01-01
Background The dental visit is a unique opportunity for tobacco control. Despite evidence of effectiveness in dental settings, brief provider-delivered cessation advice is underutilized. Objective To evaluate an Internet-delivered intervention designed to increase implementation of brief provider advice for tobacco cessation in dental practice settings. Methods Dental practices (N = 190) were randomized to the intervention website or wait-list control. Pre-intervention and after 8 months of follow-up, each practice distributed exit cards (brief patient surveys assessing provider performance, completed immediately after the dental visit) to 100 patients. Based on these exit cards, we assessed: whether patients were asked about tobacco use (ASK) and, among tobacco users, whether they were advised to quit tobacco (ADVISE). All intervention practices with follow-up exit card data were analyzed as randomized regardless of whether they participated in the Internet-delivered intervention. Results Of the 190 practices randomized, 143 (75%) dental practices provided follow-up data. Intervention practices’ mean performance improved post-intervention by 4% on ASK (29% baseline, adjusted odds ratio = 1.29 [95% CI 1.17-1.42]), and by 11% on ADVISE (44% baseline, OR = 1.55 [95% CI 1.28-1.87]). Control practices improved by 3% on ASK (Adj. OR 1.18 [95% CI 1.07-1.29]) and did not significantly improve in ADVISE. A significant group-by-time interaction effect indicated that intervention practices improved more over the study period than control practices for ADVISE (P = 0.042) but not for ASK. Conclusion This low-intensity, easily disseminated intervention was successful in improving provider performance on advice to quit. Trial Registration clinicaltrials.gov NCT00627185; http://clinicaltrials.gov/ct2/show/NCT00627185 (Archived by WebCite at http://www.webcitation.org/5c5Kugvzj) PMID:18984559
Saieg, Mauro Ajaj; Geddie, William R; Boerner, Scott L; Liu, Ni; Tsao, Ming; Zhang, Tong; Kamel-Reid, Suzanne; da Cunha Santos, Gilda
2012-06-25
Novel high-throughput molecular technologies have made the collection and storage of cells and small tissue specimens a critical issue. The FTA card provides an alternative to cryopreservation for biobanking fresh unfixed cells. The current study compared the quality and integrity of the DNA obtained from 2 types of FTA cards (Classic and Elute) using 2 different extraction protocols ("Classic" and "Elute") and assessed the feasibility of performing multiplex mutational screening using fine-needle aspiration (FNA) biopsy samples. Residual material from 42 FNA biopsies was collected in the cards (21 Classic and 21 Elute cards). DNA was extracted using the Classic protocol for Classic cards and both protocols for Elute cards. Polymerase chain reaction for p53 (1.5 kilobase) and CARD11 (500 base pair) was performed to assess DNA integrity. Successful p53 amplification was achieved in 95.2% of the samples from the Classic cards and in 80.9% of the samples from the Elute cards using the Classic protocol and 28.5% using the Elute protocol (P = .001). All samples (both cards) could be amplified for CARD11. There was no significant difference in the DNA concentration or 260/280 purity ratio when the 2 types of cards were compared. Five samples were also successfully analyzed by multiplex MassARRAY spectrometry, with a mutation in KRAS found in 1 case. High molecular weight DNA was extracted from the cards in sufficient amounts and quality to perform high-throughput multiplex mutation assays. The results of the current study also suggest that FTA Classic cards preserve better DNA integrity for molecular applications compared with the FTA Elute cards. Copyright © 2012 American Cancer Society.
Biometrics and smart cards combine to offer high security
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seidman, S.
1986-01-01
This paper discusses the Smart Card a plastic credit card sized package with an embedded computer chip which encompasses a level of technical sophistication which makes it virtually impossible to counterfeit. The question of legitimacy of the person using the Card for physical, computer, or network access can be answered by storing a biometric template of the authorized user in the Smart Card's unalterable memory. The bimetric template can be based upon a retina print, a hand print, a finger print, a wrist-vein print, a voice print, or pseudo-biometrics, such as signature dynamics, gait dynamics or keyboard typing patterns. Thesemore » Cards will function only when they are being used by the authorized individuals to whom they are issued.« less
National Aerospace Planning Process Enhancements: Analysis and Innovation
2014-03-01
and backward in time). Asset availability awareness is described based on “Dashboard” and “Magnet’s Grid” visualizations. A “Hockey Card ” metaphor...Magnets Grid” strategy for detailed visualization of air assets (i.e. aircraft). Sections 4.3.4 through 4.3.4.1 propose “Mission Hockey Cards ” to...missions). These three options are presented to the users as three rows of Mission Hockey Cards , with one Card for each new mission and for each
Personal medical information system using laser card
NASA Astrophysics Data System (ADS)
Cho, Seong H.; Kim, Keun Ho; Choi, Hyung-Sik; Park, Hyun Wook
1996-04-01
The well-known hospital information system (HIS) and the picture archiving and communication system (PACS) are typical applications of multimedia to medical area. This paper proposes a personal medical information save-and-carry system using a laser card. This laser card is very useful, especially in emergency situations, because the medical information in the laser card can be read at anytime and anywhere if there exists a laser card reader/writer. The contents of the laser card include the clinical histories of a patient such as clinical chart, exam result, diagnostic reports, images, and so on. The purpose of this system is not a primary diagnosis, but emergency reference of clinical history of the patient. This personal medical information system consists of a personal computer integrated with laser card reader/writer, color frame grabber, color CCD camera and a high resolution image scanner optionally. Window-based graphical user interface was designed for easy use. The laser card has relatively sufficient capacity to store the personal medical information, and has fast access speed to restore and load the data with a portable size as compact as a credit card. Database items of laser card provide the doctors with medical data such as laser card information, patient information, clinical information, and diagnostic result information.
Evaluation of using ferrofluid as an interface material for a field-reversible thermal connector
NASA Astrophysics Data System (ADS)
Yousif, Ahmed S.
The electrical functionality of an avionics chassis is limited due to heat dissipation limits. The limits arise due to the fact that components in an avionic computer boxes are packed very compactly, with the components mounted onto plug-in cards, and the harsh environment experienced by the chassis limits how heat can be dissipated from the cards. Convective and radiative heat transfer to the ambient are generally not possible. Therefore it is necessary to have heat transferred from the components conducted to the edge of the plug-in cards. The heat then needs to conduct from the card edge to a cold block that not only holds the card in place, but also removes the generated heat by some heat transfer fluid that is circulated through the cold block. The interface between the plug-in card and the cold block typically has a high thermal resistance since it is necessary for the card to have the capability to be re-workable, meaning that the card can be removed and then returned to the chassis. Reducing the thermal resistance of the interface is the objective of the current study and the topic of this thesis. The current design uses a pressure interface between the card and cold block. The contact pressure is increased through the addition of a wedgelock, which is a field-reversible mechanical connector. To use a wedgelock, the cold block has channels milled on the surface with widths that are larger than the thickness of the plug-in card and the un-expanded wedgelock. The card edge is placed in the channel and placed against one of the channel walls. A wedgelock is then placed between the card and the other channel wall. The wedgelock is then expanded by using either a screw or a lever. As the wedgelock expands it fills in the remaining channel gap and bears against the other face of the plug-in card. The majority of heat generated by the components on the plug-in card is forced to conduct from the card into the wall of the cold block, effectively a single sided, dry conduction heat transfer path. Having started as a student design competition named RevCon Challenge, work was performed to evaluate the use of new field-reversible thermal connectors. The new design proposed by the University of Missouri utilized oil based iron nanoparticles, commonly known as a ferrofluid, as a thermal interface material. By using a liquid type of interface material the channel gap can be reduced to a few micrometers, within machining tolerances, and heat can be dissipated off both sides of the card. The addition of nanoparticles improves the effective thermal conductivity of base fluid. The use of iron nanoparticles allows magnets to be used to hold the fluid in place, so the electronic cards may be easily inserted and removed while keeping the ferrofluid in the cold block channel. The ferrofluid-based design which was investigated has shown lower thermal resistance than the current wedgelock design. These results open the door for further development of electronic cards by using higher heat emitting components without compromising the simplicity of attaching/detaching cards from cooling plates.
An end-to-end secure patient information access card system.
Alkhateeb, A; Singer, H; Yakami, M; Takahashi, T
2000-03-01
The rapid development of the Internet and the increasing interest in Internet-based solutions has promoted the idea of creating Internet-based health information applications. This will force a change in the role of IC cards in healthcare card systems from a data carrier to an access key medium. At the Medical Informatics Department of Kyoto University Hospital we are developing a smart card patient information project where patient databases are accessed via the Internet. Strong end-to-end data encryption is performed via Secure Socket Layers, transparent to transmit patient information. The smart card is playing the crucial role of access key to the database: user authentication is performed internally without ever revealing the actual key. For easy acceptance by healthcare professionals, the user interface is integrated as a plug-in for two familiar Web browsers, Netscape Navigator and MS Internet Explorer.
MISSILE DATCOM User’s Manual - 2011 Revision
2011-03-01
out. This control card is effective only for the case in which it appears. The following data will be computed and output: Table 24. Magnus ...SOSE, SUPBOD Dynamic derivatives BDAMP, DAMP2 BDAMP, DAMP2 Magnus derivatives SPIN83, DAMP2 SPIN83, DAMP2 Plume effects BOTCNM, BOTCA, BASPRS... Magnus derivatives calculated with SPIN Control Card .................................................. 59 Table 25. Dictionary listing for the FOR020
Clipman, Steven J; Henderson-Frost, Josephine; Fu, Katherine Y; Bern, Caryn; Flores, Jorge; Gilman, Robert H
2018-01-01
About 20-30% of people infected with Chagas disease present with chronic Chagas cardiomyopathy (CCC), the most serious and frequent manifestation of the disease, while others remain asymptomatic and often do not experience Chagas-specific mortality. It is not currently well understood what causes these differential disease outcomes, but a genetic predisposition within the host could play an important role. This study examined variants in the NLRP1, CARD, and CASP1 inflammasome genes among 62 T. cruzi seropositive patients from Bolivia (38 cases with CCC and 24 asymptomatic controls) to uncover associations with CCC. All subjects underwent a complete medical examination including electrocardiogram (EKG) and echocardiogram. After genotype calling and quality control filtering with exclusion of 3 cases and 3 controls, association analysis was performed across 76 directly genotyped SNPs in NLRP1, CARD, and CASP1 genes, adjusting for age, sex, and population stratification. One SNP (rs11651270; Bonferroni-corrected p = 0.036) corresponding to a missense mutation in NLPR1 was found to be significant after adjustment for multiple testing, and a suggestive association was seen in CARD11 (rs6953573; Bonferroni-corrected p = 0.060). Although limited by sample size, the study results suggest variations in the inflammasome, particularly in NLRP1 and CARD11, may be associated with CCC.
Henderson-Frost, Josephine; Fu, Katherine Y.; Bern, Caryn; Flores, Jorge; Gilman, Robert H.
2018-01-01
About 20–30% of people infected with Chagas disease present with chronic Chagas cardiomyopathy (CCC), the most serious and frequent manifestation of the disease, while others remain asymptomatic and often do not experience Chagas-specific mortality. It is not currently well understood what causes these differential disease outcomes, but a genetic predisposition within the host could play an important role. This study examined variants in the NLRP1, CARD, and CASP1 inflammasome genes among 62 T. cruzi seropositive patients from Bolivia (38 cases with CCC and 24 asymptomatic controls) to uncover associations with CCC. All subjects underwent a complete medical examination including electrocardiogram (EKG) and echocardiogram. After genotype calling and quality control filtering with exclusion of 3 cases and 3 controls, association analysis was performed across 76 directly genotyped SNPs in NLRP1, CARD, and CASP1 genes, adjusting for age, sex, and population stratification. One SNP (rs11651270; Bonferroni-corrected p = 0.036) corresponding to a missense mutation in NLPR1 was found to be significant after adjustment for multiple testing, and a suggestive association was seen in CARD11 (rs6953573; Bonferroni-corrected p = 0.060). Although limited by sample size, the study results suggest variations in the inflammasome, particularly in NLRP1 and CARD11, may be associated with CCC. PMID:29438387
Cue Cards: A Self-Regulatory Strategy for Students with Learning Disabilities
ERIC Educational Resources Information Center
Conderman, Greg; Hedin, Laura
2011-01-01
General and special educators have used many instructional strategies to help students with learning disabilities (LD) succeed in school. One of those strategies is cue cards. As a vehicle for supporting evidence-based practices, cue cards help students (a) learn academic and behavioral steps, principles, procedures, processes, and rules; (b)…
Credit Cards on Campus: Academic Inquiry, Objective Empiricism, or Advocacy Research?
ERIC Educational Resources Information Center
Manning, Robert D.; Kirshak, Ray
2005-01-01
Professors John M. Barron and Michael E. Staten's article in Vol. 34, No. 3 of this journal, "Usage of Credit Cards Received through College Student-Marketing Programs," purports to "provide benchmark measures of college student credit card usage." Based on empirical analyses of proprietary industry data, they conclude that "There is no…
Are Rorschach Responses Influenced by Society's Change?
ERIC Educational Resources Information Center
Ames, Louise Bates
1975-01-01
Based on the general belief that people "normally" see male figures on Rorschach Card III and females on Card VII; to see the opposite, according to some, would indicate a confusing of sex roles. This study makes two comparisons: age and time changes of individual responses to these cards in different decades. (DEP)
12 CFR 226.59 - Reevaluation of rate increases.
Code of Federal Regulations, 2011 CFR
2011-01-01
... SYSTEM TRUTH IN LENDING (REGULATION Z) Special Rules Applicable to Credit Card Accounts and Open-End...) Evaluation of increased rate. If a card issuer increases an annual percentage rate that applies to a credit card account under an open-end (not home-secured) consumer credit plan, based on the credit risk of the...
12 CFR 226.59 - Reevaluation of rate increases.
Code of Federal Regulations, 2012 CFR
2012-01-01
... SYSTEM TRUTH IN LENDING (REGULATION Z) Special Rules Applicable to Credit Card Accounts and Open-End...) Evaluation of increased rate. If a card issuer increases an annual percentage rate that applies to a credit card account under an open-end (not home-secured) consumer credit plan, based on the credit risk of the...
Gustavsson, Inger; Lindell, Monica; Wilander, Erik; Strand, Anders; Gyllensten, Ulf
2009-10-01
The FTA elute micro card, which enable the collection, transport, and archiving of DNA could be an attractive alternative to a liquid based collection system for detection of human papillomavirus (HPV). To develop a method based on the FTA elute micro card for dry collection of cervical epithelial cell samples, suitable for subsequent PCR-based HPV testing. The method was evaluated by a comparison of the DNA collected by cytobrush and the regular FTA elute micro card from 50 cervical cell samples. The method was then used to estimate the DNA amount in 1040 samples applied to the indicating FTA elute micro card. The agreement in HPV positivity between the cytobrush and FTA samples (94%) was excellent (kappa=0.88, 95% CI 0.748-1). All the 1040 samples on the indicating FTA card had sufficient amounts of genomic DNA (>10 copies of a single copy gene) to be suitable for HPV typing. In 53 of the 1040 women the day in the menstrual cycle was noted, and the copy number during follicular phase day 9-13 was found to be statistically significantly lower than for the other three stages in the menstrual cycle (day 4-8, 14, >14) and during menopause. The indicating FTA elute micro card represents a suitable medium for collection of cervical cell samples, although follow-up studies are needed to verify the detection of low frequency HPV types.
SPAR demonstration problems. [for stress analysis
NASA Technical Reports Server (NTRS)
Yen, C. L.; Moore, R. A.; Whetstone, W. D.
1974-01-01
A series of examples are presented to indicate some of the principal functions of the SPAR system and to illustrate SPAR's control card-data card structure. Information in the following categories is given: (1) a description of the problem and, in most cases, comparisons with analytical solutions; (2) a list of the input cards; (3) a printout of the table of contents of the direct access library into which all SPAR output was directed; and (4) a few representative plots.
History of Satellite Orbit Determination at NSWCDD
2018-01-31
run . Segment 40 did pass editing and its use was optional after Segment 20. Segment 30 needed to be run before Segment 80. Segment 70 was run as...control cards required to run the program. These included a CHARGE card related to usage charges and various REQUEST, ATTACH, and CATALOG cards...each) could be done in a single run after the long-arc solution had converged. These short arcs used the pass matrices from the long-arc run in their
1980-12-01
Cards. Each activation of the XXXX Subprogram (XXXX=SAVE, LIBR, DISP, UNIV, SEXT , or ALLO) is associated with a certain group of DATA Cards which we...run Figure 40. The structure of the SIRIUS Data Card Package. AAAA, BBBB, .... ZZZZ replace any of SAVE, LIBR, DISP, UNIV, SEXT , ALLO. -95- The...in respect to constraining the fitted parameters. For M6ssbauer spectra containing several sextets the SEXT subprogram can be recommended. The ALLO
Telematics and smart cards in integrated health information system.
Sicurello, F; Nicolosi, A
1997-01-01
Telematics and information technology are the base on which it will be possible to build an integrated health information system to support population and improve their quality of life. This system should be based on record linkage of all data based on the interactions of the patients with the health structures, such as general practitioners, specialists, health institutes and hospitals, pharmacies, etc. The record linkage can provide the connection and integration of various records, thanks to the use of telematic technology (either urban or geographical local networks, such as the Internet) and electronic data cards. Particular emphasis should be placed on the introduction of smart cards, such as portable health cards, which will contain a standardized data set and will be sufficient to access different databases found in various health services. The inter-operability of the social-health records (including multimedia types) and the smart cards (which are one of the most important prerequisites for the homogenization and wide diffusion of these cards at an European level) should be strongly taken into consideration. In this framework a project is going to be developed aiming towards the integration of various data bases distributed territorially, from the reading of the software and the updating of the smart cards to the complete management of the patients' evaluation records, to the quality of the services offered and to the health planning. The applications developed will support epidemiological investigation software and data analysis. The inter-connection of all the databases of the various structures involved will take place through a coordination center, the most important system of which we will call "record linkage" or "integrated database". Smart cards will be distributed to a sample group of possible users and the necessary smart card management tools will be installed in all the structures involved. All the final users (the patients) in the whole network of services involved will be monitored for the duration of the project. The system users will also include general practitioners, social workers, physicians, health operators, pharmacists, laboratory workers and administrative personnel of the municipality and of the health structures concerned.
A Privacy-Protecting Authentication Scheme for Roaming Services with Smart Cards
NASA Astrophysics Data System (ADS)
Son, Kyungho; Han, Dong-Guk; Won, Dongho
In this work we propose a novel smart card based privacy-protecting authentication scheme for roaming services. Our proposal achieves so-called Class 2 privacy protection, i.e., no information identifying a roaming user and also linking the user's behaviors is not revealed in a visited network. It can be used to overcome the inherent structural flaws of smart card based anonymous authentication schemes issued recently. As shown in our analysis, our scheme is computationally efficient for a mobile user.
Managing Information On Technical Requirements
NASA Technical Reports Server (NTRS)
Mauldin, Lemuel E., III; Hammond, Dana P.
1993-01-01
Technical Requirements Analysis and Control Systems/Initial Operating Capability (TRACS/IOC) computer program provides supplemental software tools for analysis, control, and interchange of project requirements so qualified project members have access to pertinent project information, even if in different locations. Enables users to analyze and control requirements, serves as focal point for project requirements, and integrates system supporting efficient and consistent operations. TRACS/IOC is HyperCard stack for use on Macintosh computers running HyperCard 1.2 or later and Oracle 1.2 or later.
Implementing a High-Assurance Smart-Card OS
NASA Astrophysics Data System (ADS)
Karger, Paul A.; Toll, David C.; Palmer, Elaine R.; McIntosh, Suzanne K.; Weber, Samuel; Edwards, Jonathan W.
Building a high-assurance, secure operating system for memory constrained systems, such as smart cards, introduces many challenges. The increasing power of smart cards has made their use feasible in applications such as electronic passports, military and public sector identification cards, and cell-phone based financial and entertainment applications. Such applications require a secure environment, which can only be provided with sufficient hardware and a secure operating system. We argue that smart cards pose additional security challenges when compared to traditional computer platforms. We discuss our design for a secure smart card operating system, named Caernarvon, and show that it addresses these challenges, which include secure application download, protection of cryptographic functions from malicious applications, resolution of covert channels, and assurance of both security and data integrity in the face of arbitrary power losses.
Visual Media Reasoning - Terrain-based Geolocation
2015-06-01
the drawings, specifications, or other data does not license the holder or any other person or corporation ; or convey any rights or permission to...3.4 Alternative Metric Investigation This section describes a graphics processor unit (GPU) based implementation in the NVIDIA CUDA programming...utilizing 2 concurrent CPU cores, each controlling a single Nvidia C2075 Tesla Fermi CUDA card. Figure 22 shows a comparison of the CPU and the GPU powered
The adaptor molecule CARD9 is essential for tuberculosis control
Dorhoi, Anca; Desel, Christiane; Yeremeev, Vladimir; Pradl, Lydia; Brinkmann, Volker; Mollenkopf, Hans-Joachim; Hanke, Karin; Gross, Olaf; Ruland, Jürgen
2010-01-01
The cross talk between host and pathogen starts with recognition of bacterial signatures through pattern recognition receptors (PRRs), which mobilize downstream signaling cascades. We investigated the role of the cytosolic adaptor caspase recruitment domain family, member 9 (CARD9) in tuberculosis. This adaptor was critical for full activation of innate immunity by converging signals downstream of multiple PRRs. Card9−/− mice succumbed early after aerosol infection, with higher mycobacterial burden, pyogranulomatous pneumonia, accelerated granulocyte recruitment, and higher abundance of proinflammatory cytokines and granulocyte colony-stimulating factor (G-CSF) in serum and lung. Neutralization of G-CSF and neutrophil depletion significantly prolonged survival, indicating that an exacerbated systemic inflammatory disease triggered lethality of Card9−/− mice. CARD9 deficiency had no apparent effect on T cell responses, but a marked impact on the hematopoietic compartment. Card9−/− granulocytes failed to produce IL-10 after Mycobaterium tuberculosis infection, suggesting that an absent antiinflammatory feedback loop accounted for granulocyte-dominated pathology, uncontrolled bacterial replication, and, ultimately, death of infected Card9−/− mice. Our data provide evidence that deregulated innate responses trigger excessive lung inflammation and demonstrate a pivotal role of CARD9 signaling in autonomous innate host defense against tuberculosis. PMID:20351059
The automated multi-stage substructuring system for NASTRAN
NASA Technical Reports Server (NTRS)
Field, E. I.; Herting, D. N.; Herendeen, D. L.; Hoesly, R. L.
1975-01-01
The substructuring capability developed for eventual installation in Level 16 is now operational in a test version of NASTRAN. Its features are summarized. These include the user-oriented, Case Control type control language, the automated multi-stage matrix processing, the independent direct access data storage facilities, and the static and normal modes solution capabilities. A complete problem analysis sequence is presented with card-by-card description of the user input.
75 FR 75724 - Agency Information Collection Activities: Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-06
... of the OCC. The OCC requires independent credit card banks to pay an additional assessment based on receivables attributable to accounts owned by the bank. Independent credit card banks are national banks that primarily engage in credit card operations and are not affiliated with a full service national bank. The OCC...
Using Playing Cards to Simulate a Molecular Clock
ERIC Educational Resources Information Center
Westerling, Karin E.
2008-01-01
Changes in DNA base-repair may serve as an indicator of the time elapsed since divergence from a common ancestor. DNA sequences can now be analyzed. The simulation presented in this article allows students to observe the accumulation of changes in a randomly mutating sequence of playing cards. The cards are analogous to DNA nucleotide or protein…
The University of Florida's next-generation cryogenic infrared focal plane array controller system
NASA Astrophysics Data System (ADS)
Raines, Steven N.; Boreman, Glenn D.; Eikenberry, Stephen S.; Bandyopadhyay, Reba M.; Quijano, Ismael
2008-07-01
The Infrared Instrumentation Group at the University of Florida has substantial experience building IR focal plane array (FPA) controllers and seamlessly integrating them into the instruments that it builds for 8-meter class observatories, including writing device drivers for UNIX-based computer systems. We report on a design study to investigate implementing an ASIC from Teledyne Imaging Systems (TIS) into our IR FPA controller while simultaneously replacing TIS's interface card with one that eliminates the requirement for a Windows-OS computer within the instrument's control system.
Materials safety data sheets the basis for control of toxic chemicals. Volume II
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bolton, N. E.; Ketchen, E. E.; Porter, W. E.
For large industrial and research operations, maintaining reasonable control of all toxic materials used in their operations can be a formidable task. A system utilizing cards has been developed that serves a dual purpose, informing the user regarding hazards of a particular material and also facilitating appropriate workplace surveillance during its use. Selected data, including threshold limit values, routes of absorption, symptoms of exposure, chronic effects, and emergency first-aid procedures, are printed on the card. A portion of the card contains the label that the user detaches and affixes to the container. This label classifies the material according to flammability,more » toxicity, reactivity, and special properties on a 0 through 4 hazard rating system. This report describes the development and use of such cards, contains the associated Toxic Material Data Sheets that provide full backup data for the labels, and furnishes a glossary of biomedical terms used in the Data Sheets.« less
An, Younghwa
2012-01-01
Recently, many biometrics-based user authentication schemes using smart cards have been proposed to improve the security weaknesses in user authentication system. In 2011, Das proposed an efficient biometric-based remote user authentication scheme using smart cards that can provide strong authentication and mutual authentication. In this paper, we analyze the security of Das's authentication scheme, and we have shown that Das's authentication scheme is still insecure against the various attacks. Also, we proposed the enhanced scheme to remove these security problems of Das's authentication scheme, even if the secret information stored in the smart card is revealed to an attacker. As a result of security analysis, we can see that the enhanced scheme is secure against the user impersonation attack, the server masquerading attack, the password guessing attack, and the insider attack and provides mutual authentication between the user and the server.
An, Younghwa
2012-01-01
Recently, many biometrics-based user authentication schemes using smart cards have been proposed to improve the security weaknesses in user authentication system. In 2011, Das proposed an efficient biometric-based remote user authentication scheme using smart cards that can provide strong authentication and mutual authentication. In this paper, we analyze the security of Das's authentication scheme, and we have shown that Das's authentication scheme is still insecure against the various attacks. Also, we proposed the enhanced scheme to remove these security problems of Das's authentication scheme, even if the secret information stored in the smart card is revealed to an attacker. As a result of security analysis, we can see that the enhanced scheme is secure against the user impersonation attack, the server masquerading attack, the password guessing attack, and the insider attack and provides mutual authentication between the user and the server. PMID:22899887
Teaching high-school Geoscience through a group-based activity: the Geotrivia experiment
NASA Astrophysics Data System (ADS)
Bakopoulou, Athanasia
2015-04-01
Geotrivia is an educational game which aims at the enhancement of geoscience teaching in secondary education, through an interactive group-based activity. As behavioural teaching methods no longer excite students in a multitask society, new approaches should be implemented to keep up with novel learning methodologies and team-based techniques. Thus, the main aim of the experiment was to come up with an alternative learning process on geology and geography in order to upgrade and attract more students to Geosciences. Geotrivia is based on the techniques of motivation (competition to be the winner) and enjoyable educational time (it is funny to play a game) in terms of team-based student collaboration. Pedagogical aims of Geotrivia consist of team-based work, independency, autonomy and initiative, active participation, student self-evaluation and metacognition. Geotrivia is a card game, consisting of about 150 playing cards, a whistle and an hourglass. Each playing card contains a geology- or geography-related question and the answer to the question is given in the lower part of the card. Class students are divided in about 4 groups of about 5 students each. The aim of each group is to collect as many cards as possible. The hourglass is flipped and a member of the team takes the pack of cards and uses it to ask questions to his team; the other members have to answer as many questions. The team wins a card when they give a correct answer. The game is played at the end of each curriculum unit; a comprehensive version of the game is held at end of the school year. Most -but not all- questions are based on the course syllabus, which deals with the geology and geography of Europe at junior high school level (e.g. what is the cause of high seismicity in Greece?). Accordingly, Geotrivia questions can be adjusted to each country school book of geology - geography at any grade. To evaluate the results of Geotrivia, we used the methodology of pretest and posttest, an experimental group of about 50 students, which undertook Geotrivia and a control group of about 50 students, which underwent the usual teaching process. After applying Geotrivia during the last school year, the results obtained were: 1. Students accepted Geotrivia enthusiastically and realized that knowledge can be pleasantly obtained. 2. Students' participation was active and voluntary. 3. Students adhered to the rules of the game by themselves with almost no interference by the teacher, increasing their autonomy and responsibility towards the learning process. 4. Team-based work took place successfully. Team spirit and collaboration were ultimately cultivated, parameters that enforce the learning process. 5. Geotrivia appeared to be a pleasant way for chapter revision. Students were motivated to study for the next game and not for the next test, thus mastering the knowledge voluntarily and not under the fear of tests or grades. 6. Students were able to self-evaluate their knowledge through an enjoyable procedure. 7. Students had the opportunity to reach the level of metacognition purposely. 8. At the end-term exams the majority of students achieved surprisingly high grades. Therefore, the pilot run of Geotrivia has shown that it is a high standard learning process with promising results for geoscience education.
Potrich, Michele; Alves, Luis F A; Haas, Jucelaine; Da Silva, Everton R L; Daros, Alaxsandra; Pietrowski, Vanda; Neves, Pedro M O J
2009-01-01
Trichogramma pretiosum Riley and the entomopathogenic fungi Beauveria bassiana and Metarhizium anisopliae are efficient biological control agents and are thought to be used jointly. In here, we investigated if these entomopathogens could have any side-effects on T. pretiosum. Therefore, 1 x 8 cards containing sterilized eggs of Anagasta kuehniella (Zeller) that were sprayed with 0.2 ml of B. bassiana or M. anisopliae (1.0 x 10(9) conidia/ml) were offered to a T. pretiosum female for 24h (30 cards/fungus = 30 replicates). Afterwards, females were isolated in glass tubes. The control group was sprayed with sterile distillated water + Tween 80 (0.01%). In addition, 60 cards with sterilized eggs of A. kuehniella were submitted to parasitism by females of T. pretiosum for 24h. Of these cards, 30 were sprayed with B. bassiana or M. anisopliae and 30 with distillated water + Tween 80 (0.01%), and observed daily until parasitoid emergence. Metarhizium anisopliae decreased parasitoid emergence and caused confirmed mortality. Therefore, field and semi-field experiments should be conducted for a final assessment of the side-effects of these entomopathogens on Trichogramma as a ways to develop a control strategy in which both can be used.
Impact of Report Cards On Employees: A Natural Experiment
Knutson, David J.; Kind, Elizabeth A.; Fowles, Jinnet B.; Adlis, Susan
1998-01-01
To determine the effect of survey-based, health plan report cards on employees as they selected their 1995 health plan, the authors surveyed two groups of Minnesota State employees, one of which received the report card and one that did not. Both groups were surveyed before and after their enrollment. The authors looked for report card effects on relative changes in the employees' knowledge of health plan benefits and their ratings of quality and cost attributes, as well as their plan choice, rates of switching plans, and willingness to pay higher premiums. The only report card effect found was an increase in perceived knowledge for employees with single coverage. PMID:10387425
NASA Technical Reports Server (NTRS)
Hill, Randall W., Jr.
1990-01-01
The issues of knowledge representation and control in hypermedia-based training environments are discussed. The main objective is to integrate the flexible presentation capability of hypermedia with a knowledge-based approach to lesson discourse management. The instructional goals and their associated concepts are represented in a knowledge representation structure called a 'concept network'. Its functional usages are many: it is used to control the navigation through a presentation space, generate tests for student evaluation, and model the student. This architecture was implemented in HyperCLIPS, a hybrid system that creates a bridge between HyperCard, a popular hypertext-like system used for building user interfaces to data bases and other applications, and CLIPS, a highly portable government-owned expert system shell.
Médicarte software developed for the Quebec microprocessor health card project.
Lavoie, G; Tremblay, L; Durant, P; Papillon, M J; Bérubé, J; Fortin, J P
1995-01-01
The Quebec Patient Smart Card Project is a Provincial Government initiative under the responsibility of the Rgie de l'assurance-maladie du Québec (Quebec Health Insurance Board). Development, implementation, and assessment duties were assigned to a team from Université Laval, which in turn joined a group from the Direction de la santé publique du Bas-St-Laurent in Rimouski, where the experiment is taking place. The pilot project seeks to evaluate the use and acceptance of a microprocessor card as a way to improve the exchange of clinical information between card users and various health professionals. The card can be best described as a résumé containing information pertinent to an individual's health history. It is not a complete medical file; rather, it is a summary to be used as a starting point for a discussion between health professionals and patients. The target population is composed of persons 60 years and over, pregnant women, infants under 18 months, and the residents of a small town located in the target area, St-Fabien, regardless of age. The health professionals involved are general practitioners, specialists, pharmacists, nurses, and ambulance personnel. Participation in the project is on a voluntary basis. Each health care provider participating in the project has a personal identification number (PIN) and must use both an access card and a user card to access information. This prevents unauthorized access to a patient's card and allows the staff to sign and date information entered onto the patient card. To test the microprocessor card, we developed software based on a problem-oriented approach integrating diagnosis, investigations, treatments, and referrals. This software is not an expert system that constrains the clinician to a particular decisional algorithm. Instead, the software supports the physician in decision making. The software was developed with a graphical interface (Windows 3.1) to maximize its user friendliness. A version of the software was developed for each of the four groups of health care providers involved. In addition we designed an application to interface with existing pharmaceutical software. For practical reasons and to make it possible to differentiate between the different access profiles, the information stored on the card is divided in several blocks: Identification, Emergency, History (personal and family), Screening Tests, Vaccinations, Drug Profile, General follow-up, and some Specific follow-ups (Pregnancy, Ophthalmology, Kidney failure, Cardiology, Pediatrics, Diabetes, Pneumology, Specific parameters). Over 14,000 diagnoses and symptoms are classified with four levels of precision, the codification being based on the ICPC (International Classification for Primary Care). The software contains different applications to assist the clinician in decision making. A "Drug Advisor" helps the prescriber by detecting possible interactions between drugs, giving indications (doses) and contraindications, cautions, potential side-effects and therapeutic alternatives. There is also a prevention module providing recommendations for vaccination and periodic examinations based on the patient's age and sex. The pharmaceutical, vaccination, and screening tests data banks are updated every six months. These sections of the software are accessible to access card holders at any times, even without a patient card, and constitute in themselves an interesting clinical tool. We developed a software server (SCAM) allowing the different applications to access the data in a memory card regardless of the type of memory card used. Using a single high level command language, this server provides a standardized utilization of memory cards from various manufacturers. It ensures the compatibility of the applications using the card as a storage medium. (abstract truncated)
Report: EPA's Fiscal Year 2015 Purchase Card and Convenience Check Program Assessed as Low Risk
Report #16-P-0124, March 29, 2016. We determined the EPA's purchase card and convenience check program for FY 2015 to be at a low risk for illegal, improper or erroneous purchases and payments due to strengthened internal controls.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-15
... DEPARTMENT OF VETERANS AFFAIRS [OMB Control No. 2900-0548] Proposed Information Collection (Board of Veterans' Appeals Customer Satisfaction With Hearing Survey Card) Activity; Comment Request AGENCY... information technology. Title: Board of Veterans' Appeals Customer Satisfaction with Hearing Survey Card, VA...
Gutierrez, Arnel F.
2014-01-01
The complex concepts and vocabulary of biology classes discourage many students. In this study, a pretest–posttest model was used to test the effectiveness of an educational card game in reinforcing biological concepts in comparison with traditional teaching methods. The subjects of this study were two biology classes at Bulacan State University–Sarmiento Campus. Both classes received conventional instruction; however, the experimental group's instruction was supplemented with the card game, while the control group's instruction was reinforced with traditional exercises and assignments. The score increases from pretest to posttest showed that both methods effectively reinforced biological concepts, but a t test showed that the card game is more effective than traditional teaching methods. Additionally, students from the experimental group evaluated the card game using five criteria: goals, design, organization, playability, and usefulness. The students rated the material very satisfactory. PMID:24591506
Gutierrez, Arnel F
2014-01-01
The complex concepts and vocabulary of biology classes discourage many students. In this study, a pretest-posttest model was used to test the effectiveness of an educational card game in reinforcing biological concepts in comparison with traditional teaching methods. The subjects of this study were two biology classes at Bulacan State University-Sarmiento Campus. Both classes received conventional instruction; however, the experimental group's instruction was supplemented with the card game, while the control group's instruction was reinforced with traditional exercises and assignments. The score increases from pretest to posttest showed that both methods effectively reinforced biological concepts, but a t test showed that the card game is more effective than traditional teaching methods. Additionally, students from the experimental group evaluated the card game using five criteria: goals, design, organization, playability, and usefulness. The students rated the material very satisfactory.
The Educator's Guide to HyperCard and HyperTalk. A Longwood Professional Book.
ERIC Educational Resources Information Center
Culp, George H.; Watkins, G. Morgan
This book and three accompanying floppy disks introduce HyperCard 2.1 for the Macintosh microcomputer and its programming component, HyperTalk, to educators. The first four chapters introduce the basics of HyperCard, including its structure, which is based on a hierarchy of units; the use of tools and graphics; and ways of linking information…
The self-attribution bias and paranormal beliefs.
van Elk, Michiel
2017-03-01
The present study investigated the relation between paranormal beliefs, illusory control and the self-attribution bias, i.e., the motivated tendency to attribute positive outcomes to oneself while negative outcomes are externalized. Visitors of a psychic fair played a card guessing game and indicated their perceived control over randomly selected cards as a function of the congruency and valence of the card. A stronger self-attribution bias was observed for paranormal believers compared to skeptics and this bias was specifically related to traditional religious beliefs and belief in superstition. No relation between paranormal beliefs and illusory control was found. Self-report measures indicated that paranormal beliefs were associated to being raised in a spiritual family and to anomalous experiences during childhood. Thereby this study suggests that paranormal beliefs are related to specific cognitive biases that in turn are shaped by socio-cultural factors. Copyright © 2017 Elsevier Inc. All rights reserved.
Rare and Common Variants in CARD14, Encoding an Epidermal Regulator of NF-kappaB, in Psoriasis
Jordan, Catherine T.; Cao, Li; Roberson, Elisha D.O.; Duan, Shenghui; Helms, Cynthia A.; Nair, Rajan P.; Duffin, Kristina Callis; Stuart, Philip E.; Goldgar, David; Hayashi, Genki; Olfson, Emily H.; Feng, Bing-Jian; Pullinger, Clive R.; Kane, John P.; Wise, Carol A.; Goldbach-Mansky, Raphaela; Lowes, Michelle A.; Peddle, Lynette; Chandran, Vinod; Liao, Wilson; Rahman, Proton; Krueger, Gerald G.; Gladman, Dafna; Elder, James T.; Menter, Alan; Bowcock, Anne M.
2012-01-01
Psoriasis is a common inflammatory disorder of the skin and other organs. We have determined that mutations in CARD14, encoding a nuclear factor of kappa light chain enhancer in B cells (NF-kB) activator within skin epidermis, account for PSORS2. Here, we describe fifteen additional rare missense variants in CARD14, their distribution in seven psoriasis cohorts (>6,000 cases and >4,000 controls), and their effects on NF-kB activation and the transcriptome of keratinocytes. There were more CARD14 rare variants in cases than in controls (burden test p value = 0.0015). Some variants were only seen in a single case, and these included putative pathogenic mutations (c.424G>A [p.Glu142Lys] and c.425A>G [p.Glu142Gly]) and the generalized-pustular-psoriasis mutation, c.413A>C (p.Glu138Ala); these three mutations lie within the coiled-coil domain of CARD14. The c.349G>A (p.Gly117Ser) familial-psoriasis mutation was present at a frequency of 0.0005 in cases of European ancestry. CARD14 variants led to a range of NF-kB activities; in particular, putative pathogenic variants led to levels >2.5× higher than did wild-type CARD14. Two variants (c.511C>A [p.His171Asn] and c.536G>A [p.Arg179His]) required stimulation with tumor necrosis factor alpha (TNF-α) to achieve significant increases in NF-kB levels. Transcriptome profiling of wild-type and variant CARD14 transfectants in keratinocytes differentiated probably pathogenic mutations from neutral variants such as polymorphisms. Over 20 CARD14 polymorphisms were also genotyped, and meta-analysis revealed an association between psoriasis and rs11652075 (c.2458C>T [p.Arg820Trp]; p value = 2.1 × 10−6). In the two largest psoriasis cohorts, evidence for association increased when rs11652075 was conditioned on HLA-Cw∗0602 (PSORS1). These studies contribute to our understanding of the genetic basis of psoriasis and illustrate the challenges faced in identifying pathogenic variants in common disease. PMID:22521419
Minimizing drug misuse among elders: a proposal.
Craig, J A; Eves, G B
1987-01-01
This proposal is aimed at reducing the risk of adverse drug interactions that may occur when over-the-counter (OTC) preparations are taken in conjunction with prescription drugs in an unsupervised regimen. Such polymedicating is practiced widely among the elderly. A pilot program would be implemented over 12 months at three drugstores of a major retail chain. A barcode-based computer system would be used to identify potential adverse drug interactions for elderly customers. All volunteers admitted to the study, controls and subjects, would agree to buy all their medications, prescriptions and OTC, at the participating pharmacies. In return, the volunteers would receive discounts of 25 percent on prescription and OTC drugs and 10 percent on vitamins. Study subjects (N = 375) would carry barcoded identification (BID) cards that would activate the computerized program to assess each purchase for compatibility with their other medications; controls (N = 375) would carry "dummy" BID cards that would prompt the computer to approve all drug purchases. A final comparison of the subjects with the controls, as well as with a sample of elderly residents selected randomly from the community, would determine whether such a computerized, commercially based drug use review system could reduce the potential for adverse interactions between OTC and prescription drugs among the elderly. PMID:3101129
Design and implementation of reliability evaluation of SAS hard disk based on RAID card
NASA Astrophysics Data System (ADS)
Ren, Shaohua; Han, Sen
2015-10-01
Because of the huge advantage of RAID technology in storage, it has been widely used. However, the question associated with this technology is that the hard disk based on the RAID card can not be queried by Operating System. Therefore how to read the self-information and log data of hard disk has been a problem, while this data is necessary for reliability test of hard disk. In traditional way, this information can be read just suitable for SATA hard disk, but not for SAS hard disk. In this paper, we provide a method by using LSI RAID card's Application Program Interface, communicating with RAID card and analyzing the feedback data to solve the problem. Then we will get the necessary information to assess the SAS hard disk.
Human Factors Assessment of Respiratory Support Pack (RSP) Cue Card
NASA Technical Reports Server (NTRS)
Whitmore, Mihriban; Hudy, Cynthia; Smith, Danielle; Byrne, Vicky
2005-01-01
The Respiratory Support Pack (RSP) is a medical pack onboard the International Space Station (ISS) that contains much of the necessary equipment for providing aid to a conscious or unconscious crewmember in respiratory distress. Inside the RSP lid pocket is a 5.5 by 11 inch paper cue card, which is used by a Crew Medical Officer as the procedure to set up the equipment and deliver oxygen to a crewmember. In training, crewmembers expressed concerns about the readability and usability of the cue card; consequently, updating the cue card was prioritized as an activity to be completed prior to Space Shuttle return-to-flight. The Usability Testing and Analysis Facility at the Johnson Space Center evaluated the current layout of the cue card, and proposed several new cue card designs based on human factors principals. A series of three studies were performed in order to experimentally compare performance with each of the cue card designs. Nonmedically trained personnel used either a redesigned RSP cue card, or the original card to simulate resuscitation (using a mannequin along with the hardware). Time to completion, errors and subjective ratings were recorded. The addition of pictures, colors, borders, and simplification of the flow of information (making minimal changes to the actual procedure content) elicited great benefits during testing. Time to complete RSP procedures was reduced by as much as three minutes with the final cue card design. Detailed results from these studies, as well as general guidelines for cue card design will be discussed.
Learning with Multiple Representations: Extending Multimedia Learning beyond the Lab
ERIC Educational Resources Information Center
Eilam, Billie; Poyas, Yael
2008-01-01
The present study extended multimedia learning principles beyond the lab to an ecologically valid setting (homework). Eighteen information cards were used to perform three homework tasks. The control group students learned from single representation (SR) cards that presented all information as printed text. The multiple representation (MR) group…
User's guide to program FLEXSTAB. [aerodynamics
NASA Technical Reports Server (NTRS)
Cavin, R. K., III; Colunga, D.
1975-01-01
A manual is presented for correctly submitting program runs in aerodynamics on the UNIVAC 1108 computer system. All major program modules are included. Control cards are documented for the user's convenience, and card parameters are included in order to provide some idea as to reasonable time estimates for the program modules.
75 FR 80315 - Management of Federal Agency Disbursements
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-22
... Express--Cardholder Satisfaction and Usage Survey, OMB Control No. 1510-0074), 95 percent of Direct... those surveyed said they would recommend the card to a friend or family member who receives Federal...] cardholders may be unaware of important features that promote proper card usage and reduce fees, such as the...
The Michigan Context and Performance Report Card: Public Elementary & Middle Schools, 2013
ERIC Educational Resources Information Center
Spalding, Audrey
2013-01-01
The Michigan Context and Performance Report Card measures school performance by adjusting standardized test scores to account for student background. Comparing schools using unadjusted test scores ignores the significant relationship between academic performance and student socioeconomic background--a dynamic outside a school's control. The…
ERIC Educational Resources Information Center
Kennedy, Mike
2000-01-01
Examines how the use of electronic access-control system enables college and universities to provide a safer environment for students and staff. The advantages of no-key doors, adapting entry card systems for multiple uses, and successfully retaining lock and key systems when facilities do not lend themselves to electronic security are discussed.…
Improving the quality of physician communication with rapid-throughput analysis and report cards.
Farrell, Michael H; Christopher, Stephanie A; La Pean Kirschner, Alison; Roedl, Sara J; O'Tool, Faith O; Ahmad, Nadia Y; Farrell, Philip M
2014-11-01
Problems with clinician-patient communication negatively impact newborn screening, genetics, and all of healthcare. Training programs teach communication, but educational methods are not feasible for entire populations of clinicians. To address this healthcare quality gap, we developed a Communication Quality Assurance intervention. Child health providers volunteered for a randomized controlled trial of assessment and a report card. Participants provided telephone counseling to a standardized parent regarding a newborn screening result showing heterozygous status for cystic fibrosis or sickle cell disease. Our rapid-throughput timeline allows individualized feedback within a week. Two encounters were recorded (baseline and after a random sample received the report card) and abstracted for four groups of communication quality indicators. 92 participants finished both counseling encounters within our rapid-throughput time limits. Participants randomized to receive the report card improved communication behaviors more than controls, including request for teach-back (p<0.01), opening behaviors (p=0.01), anticipate/validate emotion (p<0.001) and the ratio of explained to unexplained jargon words (p<0.03). The rapid-throughput report card is effective at improving specific communication behaviors. Communication can be taught, but this project shows how healthcare organizations can assure communication quality everywhere. Further implementation could improve newborn screening, genetics, and healthcare in general. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Effects of music therapy and distraction cards on pain relief during phlebotomy in children.
Aydin, Diler; Sahiner, Nejla Canbulat
2017-02-01
To investigate three different distraction methods (distraction cards, listening to music, and distraction cards + music) on pain and anxiety relief in children during phlebotomy. This study was a prospective, randomized, controlled trial. The sample consisted of children aged 7 to 12years who required blood tests. The children were randomized into four groups, distraction cards, music, distraction cards + music, and controls. Data were obtained through face-to-face interviews with the children, their parents, and the observer before and after the procedure. The children's pain levels were assessed and reported by the parents and observers, and the children themselves who self-reported using Wong-Baker FACES. The children's anxiety levels were also assessed using the Children's Fear Scale. Two hundred children (mean age: 9.01±2.35years) were included. No difference was found between the groups in the self, parent, and observer reported procedural pain levels (p=0.72, p=0.23, p=0.15, respectively). Furthermore, no significant differences were observed between groups in procedural child anxiety levels according to the parents and observer (p=0.092, p=0.096, respectively). Pain and anxiety relief was seen in all three methods during phlebotomy; however, no statistically significant difference was observed. Copyright © 2016 Elsevier Inc. All rights reserved.
Results From Nigeria's 2016 Report Card on Physical Activity for Children and Youth.
Adeniyi, Ade F; Odukoya, Olukemi O; Oyeyemi, Adewale L; Adedoyin, Rufus A; Ojo, Olatunde S; Metseagharun, Edirin; Akinroye, Kingsley K
2016-11-01
The Nigerian Report card on Physical Activity (PA) in Children and Youth was first developed in 2013 to inform practice and policy on healthy living and prevention of noncommunicable diseases among Nigerian children and youth. This article summarizes the results of the 2016 report card and provides updated evidence on the current situation in Nigeria. A comprehensive review of literature was undertaken by the Report Card Working Group. Grades were assigned to 10 PA indicators based on the criteria used for the 2013 edition. Grades assigned to the indicators were Overall PA, D; Active Play and Leisure, C; Active Transportation, B; Sedentary Behaviors (screen-based, F and nonscreen-based, D); Overweight and Obesity, A; PA in Schools, C-; Government/Nongovernment Organizations/Private Sector/Policy, B. The following indicators were graded as Incomplete: Organized Sport and PA, Community and Built Environment, and Family and Peers. The overall PA levels of Nigerian children and youth seemed to be declining compared with the 2013 Report card but with slight improvement in active play and leisure, and PA in school settings. A substantial number of Nigerian children and youth still have high sedentary behaviors, overweight and obesity. Efforts are needed to promote PA among them.
Loss-of-function CARD8 mutation causes NLRP3 inflammasome activation and Crohn's disease.
Mao, Liming; Kitani, Atsushi; Similuk, Morgan; Oler, Andrew J; Albenberg, Lindsey; Kelsen, Judith; Aktay, Atiye; Quezado, Martha; Yao, Michael; Montgomery-Recht, Kim; Fuss, Ivan J; Strober, Warren
2018-05-01
In these studies, we evaluated the contribution of the NLRP3 inflammasome to Crohn's disease (CD) in a kindred containing individuals having a missense mutation in CARD8, a protein known to inhibit this inflammasome. Whole exome sequencing and PCR studies identified the affected individuals as having a V44I mutation in a single allele of the T60 isoform of CARD8. The serum levels of IL-1β in the affected individuals were increased compared with those in healthy controls, and their peripheral monocytes produced increased amounts of IL-1β when stimulated by NLRP3 activators. Immunoblot studies probing the basis of these findings showed that mutated T60 CARD8 failed to downregulate the NLRP3 inflammasome because it did not bind to NLRP3 and inhibit its oligomerization. In addition, these studies showed that mutated T60 CARD8 exerted a dominant-negative effect by its capacity to bind to and form oligomers with unmutated T60 or T48 CARD8 that impeded their binding to NLRP3. Finally, inflammasome activation studies revealed that intact but not mutated CARD8 prevented NLRP3 deubiquitination and serine dephosphorylation. CD due to a CARD8 mutation was not effectively treated by anti-TNF-α, but did respond to IL-1β inhibitors. Thus, patients with anti-TNF-α-resistant CD may respond to this treatment option.
Neo, Shu Hui; Chung, Ka Yan; Quek, Jia Min; Too, Heng-Phon
2017-11-30
The preservation of nucleic acids from clinical samples is critical to facilitate accurate molecular diagnosis. The use of a paper matrix, Flinders Technology Associates (FTA) Elute cards, to archive DNA and viral RNA is well-documented. However, the feasibility of FTA Elute cards for archiving serum and serum exosomal microRNAs (miRNAs) remains unclear. Here, we performed a comprehensive evaluation of FTA Elute cards for miRNA storage and recovery in different pre-analytical conditions. The recovery of serum miRNA dry-spotted on FTA Elute cards by direct elution with water at high temperature was poor. However, serum miRNAs dry-spotted on the cards were isolated with about 40% yield when using QIAzol lysis reagent and recovery was improved remarkably (>80%) upon extraction from cards pre-treated with trehalose. miRNAs stored on the cards remained stable at room temperature and can be kept for prolonged periods. Furthermore, miRNAs could be similarly recovered from serum exosomes dry-spotted on the cards. Importantly, when using sera from gastric cancer (GC) patients, the miRNAs were efficiently recovered from trehalose pre-treated cards without affecting their representation. Collectively, we have demonstrated the potential of FTA Elute cards to archive serum and serum exosomal miRNAs, making it useful for biomarker discovery and diagnostics.
Structural Insights into DD-Fold Assembly and Caspase-9 Activation by the Apaf-1 Apoptosome.
Su, Tsung-Wei; Yang, Chao-Yu; Kao, Wen-Pin; Kuo, Bai-Jiun; Lin, Shan-Meng; Lin, Jung-Yaw; Lo, Yu-Chih; Lin, Su-Chang
2017-03-07
Death domain (DD)-fold assemblies play a crucial role in regulating the signaling to cell survival or death. Here we report the crystal structure of the caspase recruitment domain (CARD)-CARD disk of the human apoptosome. The structure surprisingly reveals that three 1:1 Apaf-1:procaspase-9 CARD protomers form a novel helical DD-fold assembly on the heptameric wheel-like platform of the apoptosome. The small-angle X-ray scattering and multi-angle light scattering data also support that three protomers could form an oligomeric complex similar to the crystal structure. Interestingly, the quasi-equivalent environment of CARDs could generate different quaternary CARD assemblies. We also found that the type II interaction is conserved in all DD-fold complexes, whereas the type I interaction is found only in the helical DD-fold assemblies. This study provides crucial insights into the caspase activation mechanism, which is tightly controlled by a sophisticated and highly evolved CARD assembly on the apoptosome, and also enables better understanding of the intricate DD-fold assembly. Copyright © 2017 Elsevier Ltd. All rights reserved.
The exploration of the exhibition informatization
NASA Astrophysics Data System (ADS)
Zhang, Jiankang
2017-06-01
The construction and management of exhibition informatization is the main task and choke point during the process of Chinese exhibition industry’s transformation and promotion. There are three key points expected to realize a breakthrough during the construction of Chinese exhibition informatization, and the three aspects respectively are adopting service outsourcing to construct and maintain the database, adopting advanced chest card technology to collect various kinds of information, developing statistics analysis to maintain good cutomer relations. The success of Chinese exhibition informatization mainly calls for mature suppliers who can provide construction and maintenance of database, the proven technology, a sense of data security, advanced chest card technology, the ability of data mining and analysis and the ability to improve the exhibition service basing on the commercial information got from the data analysis. Several data security measures are expected to apply during the process of system developing, including the measures of the terminal data security, the internet data security, the media data security, the storage data security and the application data security. The informatization of this process is based on the chest card designing. At present, there are several types of chest card technology: bar code chest card; two-dimension code card; magnetic stripe chest card; smart-chip chest card. The information got from the exhibition data will help the organizers to make relevant service strategies, quantify the accumulated indexes of the customers, and improve the level of the customer’s satisfaction and loyalty, what’s more, the information can also provide more additional services like the commercial trips, VIP ceremonial reception.
Promoting healthy weight among elementary school children via a health report card approach.
Chomitz, Virginia R; Collins, Jessica; Kim, Juhee; Kramer, Ellen; McGowan, Robert
2003-08-01
As overweight continues to rise among children, schools seek effective and sensitive ways to engage parents in promoting healthy weight. To evaluate a school-based health report card on the family awareness of and concern about the child weight status, plans for weight control, and preventive behaviors. Quasi-experimental field trial with a personalized weight and fitness health report card intervention (PI), a general-information intervention (GI), and a control group (CG). Outcomes were assessed using a postintervention telephone survey, including process and outcome measures. The intervention included 1396 ethnically diverse students at 4 elementary schools in an urban area. Telephone surveys were completed by 399 families from an evaluation sample of 793. Intervention Families were randomly assigned to the PI, GI, or CG and mailed intervention materials. The CG was mailed GI materials after the survey. Parent awareness of child weight status, concerns, weight-control plans, and preventive behaviors. Group effects were significantly different by the child's weight status, so results were stratified. Among overweight students, intervention parents were more likely to know their child's weight status (PI, 44%; GI, 41%; CG, 23%) (P =.02). The PI parents planned medical help (PI, 25%; GI, 7%; CG, 9%) (P =.004), dieting activities (PI, 19%; GI and CG, <5 cases) (P =.02) and physical activities (PI, 42%; GI, 27%; CG, 13%) (P<.001) for their overweight children. No group effect on concern or preventive behaviors was detected. Most parents of overweight children who read materials requested annual weight and health information on their child (PI, 91%; GI, 67%). Among overweight children, the PI was associated with increased parental awareness of their child's weight status. Although parents wanted PI for their children, more research is needed to test this approach on children's self-esteem and plans for weight control.
van Belle, Elise; Zwakhalen, Sandra M G; Caris, Josien; Van Hecke, Ann; Huisman-de Waal, Getty; Heinen, Maud
2018-02-01
To describe the tailoring of the Tell-us Card intervention for enhanced patient participation to the Dutch hospital setting using Intervention Mapping as a systematic approach. Even though patient participation is essential in any patient-to-nurse encounter, care plans often fail to take patients' preferences into account. The Tell-us Card intervention seems promising, but needs to be tailored and tested before implementation in a different setting or on large scale. Description of the Intervention Mapping framework to systematically tailor the Tell-us Card intervention to the Dutch hospital setting. Intervention Mapping consists of: (i) identification of the problem through needs assessment and determination of fit, based on patients and nurses interviews and focus group interviews; (ii) developing a logic model of change and matrices, based on literature and interviews; (iii) selection of theory-based methods and practical applications; (iv) producing programme components and piloting; (v) planning for adoption, implementation and sustainability; and (vi) preparing for programme evaluation. Knowledge, attitude, outcome expectations, self-efficacy and skills were identified as the main determinants influencing the use of the Tell-us Card. Linking identified determinants and performance objectives with behaviour change techniques from the literature resulted in a well-defined and tailored intervention and evaluation plan. The Tell-us Card intervention was adapted to fit the Dutch hospital setting and prepared for evaluation. The Medical Research Council framework was followed, and the Intervention Mapping approach was used to prepare a pilot study to confirm feasibility and relevant outcomes. This article shows how Intervention Mapping is applied within the Medical Research Council framework to adapt the Tell-us Card intervention, which could serve as a guide for the tailoring of similar interventions. © 2017 John Wiley & Sons Ltd.
The Application Design of Solar Radio Spectrometer Based on FPGA
NASA Astrophysics Data System (ADS)
Du, Q. F.; Chen, R. J.; Zhao, Y. C.; Feng, S. W.; Chen, Y.; Song, Y.
2017-10-01
The Solar radio spectrometer is the key instrument to observe solar radio. By programing the computer software, we control the AD signal acquisition card which is based on FPGA to get a mass of data. The data are transferred by using PCI-E port. This program has realized the function of timing data collection, finding data in specific time and controlling acquisition meter in real time. It can also map the solar radio power intensity graph. By doing the experiment, we verify the reliability of solar radio spectrum instrument, in the meanwhile, the instrument simplifies the operation in observing the sun.
Riis, Lene; Vind, Ida; Vermeire, Severine; Wolters, Frank; Katsanos, Kostas; Politi, Patrizia; Freitas, João; Mouzas, Ioannis A; O'Morain, Colm; Ruiz-Ochoa, Victor; Odes, Selwyn; Binder, Vibeke; Munkholm, Pia; Moum, Bjørn; Stockbrügger, Reinhold; Langholz, Ebbe
2007-01-01
The aetiology of inflammatory bowel disease (IBD) is unknown, but it has become evident that genetic factors are involved in disease susceptibility. Studies have suggested a north-south gradient in the incidence of IBD, raising the question whether this difference is caused by genetic heterogeneity. We aimed to investigate the prevalence of polymorphisms in CARD15 and TLR4 and occurrence of anti-Saccharomyces cerevisiae (ASCA) and antineutrophil cytoplasmic antibodies (pANCA) in a European population-based IBD cohort. Individuals from the incident cohort were genotyped for three mutations in CARD15 and the Asp299gly mutation in TLR4. Levels of ASCA and pANCA were assessed. Disease location and behaviour at time of diagnosis was obtained from patient files. Overall CARD15 mutation rate was 23.9% for CD and 9.6% for UC patients (P < 0.001). Mutations were less present in the Scandinavian countries (12.1%) versus the rest of Europe (32.8%) (P < 0.001). Overall population attributable risk was 11.2%. TLR4 mutation rate was 7.6% in CD, 6.7% in UC patients and 12.3% in healthy controls (HC), highest among South European CD patients and HC. ASCA was seen in 28.5% of CD patients with no north-south difference, and was associated with complicated disease. pANCA was most common in North European UC patients and not associated with disease phenotype. The prevalence of mutations in CARD15 varied across Europe, and was not correlated to the incidence of CD. There was no association between mutations in TLR4 and IBD. The prevalence of ASCA was relatively low; however related to severe CD.
Santos Neto, Edson Theodoro dos; Oliveira, Adauto Emmerich; Zandonade, Eliana; Gama, Silvana Granado Nogueira da; Leal, Maria do Carmo
2012-09-01
This study aimed to assess the completeness of prenatal care information on the patients' prenatal care cards, according to coverage by various public health services: Family Health Strategy (FHS), Community-Based Health Workers' Program (CBHWP), and traditional Primary Care Units (PCU) in Greater Metropolitan Vitória, Espírito Santo State, Brazil. In a cross-sectional study, 1,006 prenatal cards were randomly selected from postpartum women at maternity hospitals in the metropolitan area. Completeness of the cards was assessed according to the criteria proposed by Romero & Cunha, which measure the quality on a scale from excellent (< 5% incomplete cards) to very bad (> 50% incomplete cards). In general, completion of information on the cards was bad (> 20% incomplete), but cards were filled out better in the FHS than in the CBHWP and PCU, especially for tetanus vaccination (p = 0.016) and gestational weight (p = 0.039). In conclusion, the quality of prenatal care in the public health system in Greater Metropolitan Vitória fails to meet the Brazilian national guidelines for maternal and child health.
ERIC Educational Resources Information Center
Russell-Smith, Suzanna N.; Comerford, Bronwynn J. E.; Maybery, Murray T.; Whitehouse, Andrew J. O.
2014-01-01
This study investigated the involvement of inner speech limitations in the executive dysfunction associated with autism spectrum disorders (ASDs). Seventeen children with ASD and 18 controls, statistically-matched in age and IQ, performed a computer-based card sorting test (CST) to assess cognitive flexibility under four conditions: baseline, with…
A Directory of Sources of Information and Data Bases on Education and Training.
1980-09-01
ACADO07 National Opinion Research Center (NORC) ... ............. ... ACADOO8 U of California Union Catalog Supp. (1963-1967...Records (RSR) ...... .................. ... ARMYO30 Union Central Registry System (UCRSYS) .... .............. ... ARMY032 Training Control Card Report...research. Your query directs a computer search of the Compre- hensive Dissertation Database. The search produces a list of all titles matching your
ERIC Educational Resources Information Center
Nieuwenhuysen, Paul
1997-01-01
Explores data transfer speeds obtained with various combinations of hardware and software components through a study of access to the Internet from a notebook computer connected to a local area network based on Ethernet and TCP/IP (transmission control protocol/Internet protocol) network protocols. Upgrading is recommended for higher transfer…
Valentine, Anne; DeAngelo, Darcie; Alegría, Margarita; Cook, Benjamin L.
2014-01-01
Report cards have been used to increase accountability and quality of care in health care settings, and to improve state infrastructure for providing quality mental health care services. However, to date, report cards have not been used to compare states on racial/ethnic disparities in mental health care. This qualitative study examines reactions of mental health care policymakers to a proposed mental health care disparities report card generated from population-based survey data of mental health and mental health care utilization. We elicited feedback about the content, format, and salience of the report card. Interviews were conducted with nine senior advisors to state policymakers and one policy director of a national non-governmental organization from across the U.S. Four primary themes emerged: fairness in state-by-state comparisons; disconnect between the goals and language of policymakers and researchers; concerns about data quality and; targeted suggestions from policymakers. Participant responses provide important information that can contribute to making evidence-based research more accessible to policymakers. Further, policymakers suggested ways to improve the structure and presentation of report cards to make them more accessible to policymakers and to foster equity considerations during the implementation of new health care legislation. To reduce mental health care disparities, effort is required to facilitate understanding between researchers and relevant stakeholders about research methods, standards for interpretation of research-based evidence and its use in evaluating policies aimed at ameliorating disparities. PMID:25383993
31 CFR 594.410 - Credit extended and cards issued by U.S. financial institutions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 31 Money and Finance:Treasury 3 2012-07-01 2012-07-01 false Credit extended and cards issued by U.S. financial institutions. 594.410 Section 594.410 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY GLOBAL...
31 CFR 546.409 - Credit extended and cards issued by U.S. financial institutions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Credit extended and cards issued by U.S. financial institutions. 546.409 Section 546.409 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY DARFUR...
Impact of the Shodan Computer Search Engine on Internet-facing Industrial Control System Devices
2014-03-27
bridge implementation. The transparent bridge is designed using a Raspberry Pi configured with Linux IPtables and bridge-utils to bridge the on board...Ethernet card and a second USB Ethernet adapter. A Raspberry Pi is a credit-card-sized single-board computer running a version of Debian Linux. There
PUNCHED CARD SYSTEM NEEDN'T BE COMPLEX TO GIVE COMPLETE CONTROL.
ERIC Educational Resources Information Center
BEMIS, HAZEL T.
AT WORCESTER JUNIOR COLLEGE, MASSACHUSETTS, USE OF A MANUALLY OPERATED PUNCHED CARD SYSTEM HAS RESULTED IN (1) SIMPLIFIED REGISTRATION PROCEDURES, (2) QUICK ANALYSIS OF CONFLICTS AND PROBLEMS IN CLASS SCHEDULING, (3) READY ACCESS TO STATISTICAL INFORMATION, (4) DIRECTORY INFORMATION IN A WIDE RANGE OF CLASSIFICATIONS, (5) EASY VERIFICATION OF…
Wisconsin Card Sorting Test Performance in Children with Developmental Coordination Disorder
ERIC Educational Resources Information Center
Wuang, Yee-Pay; Su, Chwen-Yng; Su, Jui-Hsing
2011-01-01
The primary purpose of this study was to investigate and compare the executive functions measured by the Wisconsin Card Sorting Test (WCST) between children with developmental coordination disorder (DCD) and age-matched normal controls. A second purpose was to examine the relations between executive functions and school functions in DCD children.…
An interactive web-based application for Comprehensive Analysis of RNAi-screen Data.
Dutta, Bhaskar; Azhir, Alaleh; Merino, Louis-Henri; Guo, Yongjian; Revanur, Swetha; Madhamshettiwar, Piyush B; Germain, Ronald N; Smith, Jennifer A; Simpson, Kaylene J; Martin, Scott E; Buehler, Eugen; Beuhler, Eugen; Fraser, Iain D C
2016-02-23
RNAi screens are widely used in functional genomics. Although the screen data can be susceptible to a number of experimental biases, many of these can be corrected by computational analysis. For this purpose, here we have developed a web-based platform for integrated analysis and visualization of RNAi screen data named CARD (for Comprehensive Analysis of RNAi Data; available at https://card.niaid.nih.gov). CARD allows the user to seamlessly carry out sequential steps in a rigorous data analysis workflow, including normalization, off-target analysis, integration of gene expression data, optimal thresholds for hit selection and network/pathway analysis. To evaluate the utility of CARD, we describe analysis of three genome-scale siRNA screens and demonstrate: (i) a significant increase both in selection of subsequently validated hits and in rejection of false positives, (ii) an increased overlap of hits from independent screens of the same biology and (iii) insight to microRNA (miRNA) activity based on siRNA seed enrichment.
An interactive web-based application for Comprehensive Analysis of RNAi-screen Data
Dutta, Bhaskar; Azhir, Alaleh; Merino, Louis-Henri; Guo, Yongjian; Revanur, Swetha; Madhamshettiwar, Piyush B.; Germain, Ronald N.; Smith, Jennifer A.; Simpson, Kaylene J.; Martin, Scott E.; Beuhler, Eugen; Fraser, Iain D. C.
2016-01-01
RNAi screens are widely used in functional genomics. Although the screen data can be susceptible to a number of experimental biases, many of these can be corrected by computational analysis. For this purpose, here we have developed a web-based platform for integrated analysis and visualization of RNAi screen data named CARD (for Comprehensive Analysis of RNAi Data; available at https://card.niaid.nih.gov). CARD allows the user to seamlessly carry out sequential steps in a rigorous data analysis workflow, including normalization, off-target analysis, integration of gene expression data, optimal thresholds for hit selection and network/pathway analysis. To evaluate the utility of CARD, we describe analysis of three genome-scale siRNA screens and demonstrate: (i) a significant increase both in selection of subsequently validated hits and in rejection of false positives, (ii) an increased overlap of hits from independent screens of the same biology and (iii) insight to microRNA (miRNA) activity based on siRNA seed enrichment. PMID:26902267
Secure E-Business applications based on the European Citizen Card
NASA Astrophysics Data System (ADS)
Zipfel, Christian; Daum, Henning; Meister, Gisela
The introduction of ID cards enhanced with electronic authentication services opens up the possibility to use these for identification and authentication in e-business applications. To avoid incompatible national solutions, the specification of the European Citizen Card aims at defining interoperable services for such use cases. Especially the given device authentication methods can help to eliminate security problems with current e-business and online banking applications.
Design of Formats and Packs of Catalog Cards.
ERIC Educational Resources Information Center
OCLC Online Computer Library Center, Inc., Dublin, OH.
The three major functions of the Ohio College Library Center's Shared Cataloging System are: 1) provision of union catalog location listing; 2) making available cataloging done by one library to all other users of the system; and 3) production of catalog cards. The system, based on a central machine readable data base, speeds cataloging and…
Business Japanese, a HyperCard Simulation.
ERIC Educational Resources Information Center
Saito-Abbott, Yoshiko; Abbott, Thomas
This paper describes Business Japanese (BJ), a HyperCard based tutorial designed as courseware for use in a third-year Japanese course at the University of Texas, Austin (UTA). A major objective was to develop good courseware based on proven language learning theory that would integrate theory, practice, and technology. BJ stresses a realistic and…
A credit card verifier structure using diffraction and spectroscopy concepts
NASA Astrophysics Data System (ADS)
Sumriddetchkajorn, Sarun; Intaravanne, Yuttana
2008-04-01
We propose and experimentally demonstrate an angle-multiplexing based optical structure for verifying a credit card. Our key idea comes from the fact that the fine detail of the embossed hologram stamped on the credit card is hard to duplicate and therefore its key color features can be used for distinguishing between the real and counterfeit ones. As the embossed hologram is a diffractive optical element, we choose to shine one at a time a number of broadband lightsources, each at different incident angle, on the embossed hologram of the credit card in such a way that different color spectra per incident angle beam is diffracted and separated in space. In this way, the number of pixels of each color plane is investigated. Then we apply a feed forward back propagation neural network configuration to separate the counterfeit credit card from the real one. Our experimental demonstration using two off-the-shelf broadband white light emitting diodes, one digital camera, a 3-layer neural network, and a notebook computer can identify all 69 counterfeit credit cards from eight real credit cards.
Gulten, Gulcin; Sacchettini, James C
2013-10-08
CarD from Mycobacterium tuberculosis (Mtb) is an essential protein shown to be involved in stringent response through downregulation of rRNA and ribosomal protein genes. CarD interacts with the β-subunit of RNAP and this interaction is vital for Mtb's survival during the persistent infection state. We have determined the crystal structure of CarD in complex with the RNAP β-subunit β1 and β2 domains at 2.1 Å resolution. The structure reveals the molecular basis of CarD/RNAP interaction, providing a basis to further our understanding of RNAP regulation by CarD. The structural fold of the CarD N-terminal domain is conserved in RNAP interacting proteins such as TRCF-RID and CdnL, and displays similar interactions to the predicted homology model based on the TRCF/RNAP β1 structure. Interestingly, the structure of the C-terminal domain, which is required for complete CarD function in vivo, represents a distinct DNA-binding fold. Copyright © 2013 Elsevier Ltd. All rights reserved.
Janse, Marcel; Lamberts, Laetitia E; Franke, Lude; Raychaudhuri, Soumya; Ellinghaus, Eva; Muri Boberg, Kirsten; Melum, Espen; Folseraas, Trine; Schrumpf, Erik; Bergquist, Annika; Björnsson, Einar; Fu, Jingyuan; Jan Westra, Harm; Groen, Harry J M; Fehrmann, Rudolf S N; Smolonska, Joanna; van den Berg, Leonard H; Ophoff, Roel A; Porte, Robert J; Weismüller, Tobias J; Wedemeyer, Jochen; Schramm, Christoph; Sterneck, Martina; Günther, Rainer; Braun, Felix; Vermeire, Severine; Henckaerts, Liesbet; Wijmenga, Cisca; Ponsioen, Cyriel Y; Schreiber, Stefan; Karlsen, Tom H; Franke, Andre; Weersma, Rinse K
2011-06-01
Primary sclerosing cholangitis (PSC) is a chronic cholestatic liver disease characterized by inflammation and fibrosis of the bile ducts. Both environmental and genetic factors contribute to its pathogenesis. To further clarify its genetic background, we investigated susceptibility loci recently identified for ulcerative colitis (UC) in a large cohort of 1,186 PSC patients and 1,748 controls. Single nucleotide polymorphisms (SNPs) tagging 13 UC susceptibility loci were initially genotyped in 854 PSC patients and 1,491 controls from Benelux (331 cases, 735 controls), Germany (265 cases, 368 controls), and Scandinavia (258 cases, 388 controls). Subsequently, a joint analysis was performed with an independent second Scandinavian cohort (332 cases, 257 controls). SNPs at chromosomes 2p16 (P-value 4.12 × 10(-4) ), 4q27 (P-value 4.10 × 10(-5) ), and 9q34 (P-value 8.41 × 10(-4) ) were associated with PSC in the joint analysis after correcting for multiple testing. In PSC patients without inflammatory bowel disease (IBD), SNPs at 4q27 and 9q34 were nominally associated (P < 0.05). We applied additional in silico analyses to identify likely candidate genes at PSC susceptibility loci. To identify nonrandom, evidence-based links we used GRAIL (Gene Relationships Across Implicated Loci) analysis showing interconnectivity between genes in six out of in total nine PSC-associated regions. Expression quantitative trait analysis from 1,469 Dutch and UK individuals demonstrated that five out of nine SNPs had an effect on cis-gene expression. These analyses prioritized IL2, CARD9, and REL as novel candidates. We have identified three UC susceptibility loci to be associated with PSC, harboring the putative candidate genes REL, IL2, and CARD9. These results add to the scarce knowledge on the genetic background of PSC and imply an important role for both innate and adaptive immunological factors. Copyright © 2011 American Association for the Study of Liver Diseases.
Optical security features for plastic card documents
NASA Astrophysics Data System (ADS)
Hossick Schott, Joachim
1998-04-01
Print-on-demand is currently a major trend in the production of paper based documents. This fully digital production philosophy will likely have ramifications also for the secure identification document market. Here, plastic cards increasingly replace traditionally paper based security sensitive documents such as drivers licenses and passports. The information content of plastic cards can be made highly secure by using chip cards. However, printed and other optical security features will continue to play an important role, both for machine readable and visual inspection. Therefore, on-demand high resolution print technologies, laser engraving, luminescent pigments and laminated features such as holograms, kinegrams or phase gratings will have to be considered for the production of secure identification documents. Very important are also basic optical, surface and material durability properties of the laminates as well as the strength and nature of the adhesion between the layers. This presentation will address some of the specific problems encountered when optical security features such as high resolution printing and laser engraving are to be integrated in the on-demand production of secure plastic card identification documents.
Wang, Shao-Ming; Hu, Shang-Ying; Chen, Feng; Chen, Wen; Zhao, Fang-Hui; Zhang, Yu-Qing; Ma, Xin-Ming; Qiao, You-Lin
2014-01-01
To make the clinical evaluation of a solid-state human papillomavirus (HPV) sampling medium in combination with an economical HPV testing method (careHPV™) for cervical cancer screening. 396 women aged 25-65 years were enrolled for cervical cancer screening, and four samples were collected. Two samples were collected by woman themselves, among which one was stored in DCM preservative solution (called "liquid sample") and the other was applied on the Whatman Indicating FTA Elute® card (FTA card). Another two samples were collected by physician and stored in DCM preservative solution and FTA card, respectively. All the samples were detected by careHPV™ test. All the women were administered a colposcopy examination, and biopsies were taken for pathological confirmation if necessary. FTA card demonstrated a comparable sensitivity of detecting high grade Cervical Intraepithelial Neoplasia (CIN) with the liquid sample carrier for self and physician-sampling, but showed a higher specificity than that of liquid sample carrier for self-sampling (FTA vs Liquid: 79.0% vs 71.6%, p=0.02). Generally, the FTA card had a comparable accuracy with that of Liquid-based medium by different sampling operators, with an area under the curve of 0.807 for physician and FTA, 0.781 for physician and Liquid, 0.728 for self and FTA, and 0.733 for self and Liquid (p>0.05). FTA card is a promising sample carrier for cervical cancer screening. With appropriate education programmes and further optimization of the experimental workflow, FTA card based self-collection in combination with centralized careHPV™ testing can help expand the coverage of cervical cancer screening in low-resource areas.
Gema Díaz-Blancat; Juan García-Prieto; Fernando Maestú; Francisco Barceló
2018-05-01
One common assumption has been that prefrontal executive control is mostly required for target detection (Posner and Petersen in Ann Rev Neurosci 13:25-42, 1990). Alternatively, cognitive control has also been related to anticipatory updating of task-set (contextual) information, a view that highlights proactive control processes. Frontoparietal cortical networks contribute to both proactive control and reactive target detection, although their fast dynamics are still largely unexplored. To examine this, we analyzed rapid magnetoencephalographic (MEG) source activations elicited by task cues and target cards in a task-cueing analogue of the Wisconsin Card Sorting Test. A single-task (color sorting) condition with equivalent perceptual and motor demands was used as a control. Our results revealed fast, transient and largely switch-specific MEG activations across frontoparietal and cingulo-opercular regions in anticipation of target cards, including (1) early (100-200 ms) cue-locked MEG signals at visual, temporo-parietal and prefrontal cortices of the right hemisphere (i.e., calcarine sulcus, precuneus, inferior frontal gyrus, anterior insula and supramarginal gyrus); and (2) later cue-locked MEG signals at the right anterior and posterior insula (200-300 ms) and the left temporo-parietal junction (300-500 ms). In all cases larger MEG signal intensity was observed in switch relative to repeat cueing conditions. Finally, behavioral restart costs and test scores of working memory capacity (forward digit span) correlated with cue-locked MEG activations at key nodes of the frontoparietal network. Together, our findings suggest that proactive cognitive control of task rule updating can be fast and transiently implemented within less than a second and in anticipation of target detection.
Age verification cards fail to fully prevent minors from accessing tobacco products.
Kanda, Hideyuki; Osaki, Yoneatsu; Ohida, Takashi; Kaneita, Yoshitaka; Munezawa, Takeshi
2011-03-01
Proper age verification can prevent minors from accessing tobacco products. For this reason, electronic locking devices based on a proof-of age system utilising cards were installed in almost every tobacco vending machine across Japan and Germany to restrict sales to minors. We aimed to clarify the associations between amount smoked by high school students and the usage of age verification cards by conducting a nationwide cross-sectional survey of students in Japan. This survey was conducted in 2008. We asked high school students, aged 13-18 years, in Japan about their smoking behaviour, where they purchase cigarettes, if or if not they have used age verification cards, and if yes, how they obtained this card. As the amount smoked increased, the prevalence of purchasing cigarettes from vending machines also rose for both males and females. The percentage of those with experience of using an age verification card was also higher among those who smoked more. Somebody outside of family was the top source of obtaining cards. Surprisingly, around 5% of males and females belonging to the group with highest smoking levels applied for cards themselves. Age verification cards cannot fully prevent minors from accessing tobacco products. These findings suggest that a total ban of tobacco vending machines, not an age verification system, is needed to prevent sales to minors.
Field-Programmable Gate Array-based fluxgate magnetometer with digital integration
NASA Astrophysics Data System (ADS)
Butta, Mattia; Janosek, Michal; Ripka, Pavel
2010-05-01
In this paper, a digital magnetometer based on printed circuit board fluxgate is presented. The fluxgate is pulse excited and the signal is extracted by gate integration. We investigate the possibility to perform integration on very narrow gates (typically 500 ns) by using digital techniques. The magnetometer is based on field-programmable gate array (FPGA) card: we will show all the advantages and disadvantages, given by digitalization of fluxgate output voltage by means of analog-to-digital converter on FPGA card, as well as digitalization performed by external digitizer. Due to very narrow gate, it is shown that a magnetometer entirely based on a FPGA card is preferable, because it avoids noise due to trigger instability. Both open loop and feedback operative mode are described and achieved results are presented.
NASA Astrophysics Data System (ADS)
HUSEJKO, Michal; EVANS, John; RASTEIRO DA SILVA, Jose Carlos
2015-12-01
High-Level Synthesis (HLS) for Field-Programmable Logic Array (FPGA) programming is becoming a practical alternative to well-established VHDL and Verilog languages. This paper describes a case study in the use of HLS tools to design FPGA-based data acquisition systems (DAQ). We will present the implementation of the CERN CMS detector ECAL Data Concentrator Card (DCC) functionality in HLS and lessons learned from using HLS design flow. The DCC functionality and a definition of the initial system-level performance requirements (latency, bandwidth, and throughput) will be presented. We will describe how its packet processing control centric algorithm was implemented with VHDL and Verilog languages. We will then show how the HLS flow could speed up design-space exploration by providing loose coupling between functions interface design and functions algorithm implementation. We conclude with results of real-life hardware tests performed with the HLS flow-generated design with a DCC Tester system.
Comparing 2 National Organization-Level Workplace Health Promotion and Improvement Tools, 2013–2015
Lang, Jason E.; Davis, Whitney D.; Jones-Jack, Nkenge H.; Mukhtar, Qaiser; Lu, Hua; Acharya, Sushama D.; Molloy, Meg E.
2016-01-01
Creating healthy workplaces is becoming more common. Half of employers that have more than 50 employees offer some type of workplace health promotion program. Few employers implement comprehensive evidence-based interventions that reach all employees and achieve desired health and cost outcomes. A few organization-level assessment and benchmarking tools have emerged to help employers evaluate the comprehensiveness and rigor of their health promotion offerings. Even fewer tools exist that combine assessment with technical assistance and guidance to implement evidence-based practices. Our descriptive analysis compares 2 such tools, the Centers for Disease Control and Prevention’s Worksite Health ScoreCard and Prevention Partners’ WorkHealthy America, and presents data from both to describe workplace health promotion practices across the United States. These tools are reaching employers of all types (N = 1,797), and many employers are using a comprehensive approach (85% of those using WorkHealthy America and 45% of those using the ScoreCard), increasing program effectiveness and impact. PMID:27685429
Data Supporting Mobile Application Development for Use within the Marine Air-Ground Task Force
2015-09-01
Landing Zone (LZ) Brief Maneuver Control Measures Medical Evacuation (MEDEVAC) Request Mission Card Information Obstacle Report Rules of Engagement...2 2 4 3 4 28 Landing%Zone%(LZ)%Brief% 2 3 1 3 4 2 2 3 3 4 27 Mission% Card %Information 3 2 2 3 3 2 2 3 3 3 26 5%Paragraph%Order 3 2 2 2 2 3 4 3 1 2 24...SALUTE, and Mission Card . These constitute what could be identified as a type of reporting application. Within one application, a number of different
Leung, S C; Fung, W K; Wong, K H
1999-01-01
The relative bit density variation graphs of 207 specimen credit cards processed by 12 encoding machines were examined first visually, and then classified by means of hierarchical cluster analysis. Twenty-nine credit cards being treated as 'questioned' samples were tested by way of cluster analysis against 'controls' derived from known encoders. It was found that hierarchical cluster analysis provided a high accuracy of identification with all 29 'questioned' samples classified correctly. On the other hand, although visual comparison of jitter graphs was less discriminating, it was nevertheless capable of giving a reasonably accurate result.
Qiu, Shuming; Xu, Guoai; Ahmad, Haseeb; Guo, Yanhui
2018-01-01
The Session Initiation Protocol (SIP) is an extensive and esteemed communication protocol employed to regulate signaling as well as for controlling multimedia communication sessions. Recently, Kumari et al. proposed an improved smart card based authentication scheme for SIP based on Farash's scheme. Farash claimed that his protocol is resistant against various known attacks. But, we observe some accountable flaws in Farash's protocol. We point out that Farash's protocol is prone to key-compromise impersonation attack and is unable to provide pre-verification in the smart card, efficient password change and perfect forward secrecy. To overcome these limitations, in this paper we present an enhanced authentication mechanism based on Kumari et al.'s scheme. We prove that the proposed protocol not only overcomes the issues in Farash's scheme, but it can also resist against all known attacks. We also provide the security analysis of the proposed scheme with the help of widespread AVISPA (Automated Validation of Internet Security Protocols and Applications) software. At last, comparing with the earlier proposals in terms of security and efficiency, we conclude that the proposed protocol is efficient and more secure.
Lalani, Tahaniyat; Tisdale, Michele D; Maguire, Jason D; Wongsrichanalai, Chansuda; Riddle, Mark S; Tribble, David R
2015-01-01
We evaluated the limits of detection (LoD) for an 11-plex PCR-Luminex assay performed on Whatman FTA Elute cards smeared with stool containing pathogens associated with travelers’ diarrhea. LoDs ranged between 102-105 CFU, PFU or cysts/g for most pathogens except Cryptosporidium. Campylobacter and norovirus LoD increased with prolonged storage of cards. PMID:26072151
Malvey, Donna; Fottler, Myron D; Slovensky, Donna J
2002-01-01
In the highly competitive health care environment, the survival of an organization may depend on how well powerful stakeholders are managed. Yet, the existing strategic stakeholder management process does not include evaluation of stakeholder management performance. To address this critical gap, this paper proposes a systematic method for evaluation using a stakeholder report card. An example of a physician report card based on this methodology is presented.
ERIC Educational Resources Information Center
Anderson, Carla; Card, Karen
2015-01-01
The purpose of this quasi-experimental nonequivalent control group study was to determine the influence that a financial education intervention administered in First Year Experience courses had on students' perceptions of their financial behavior such as compulsive spending and credit card use. This study utilized the five-point Likert-type…
12 CFR Appendix M2 to Part 226 - Actual Repayment Disclosures
Code of Federal Regulations, 2010 CFR
2010-01-01
... Disclosures (a) Calculating actual repayment disclosures. (1) Definitions. (i) “Retail credit card” means a credit card that is issued by a retailer that can be used only in transactions with the retailer or a group of retailers that are related by common ownership or control, or a credit card where a retailer...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-14
...: Statement Regarding a Lost or Stolen U.S. Passport Book and/or Card ACTION: Notice of request for public... Information Collection: Statement Regarding a Lost or Stolen U.S. Passport Book and/or Card. OMB Control...: Bureau of Consular Affairs, Passport Services, Office of Program Management and Operational Support...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-01
... card request. The comment period is being extended to provide additional time for interested parties to... times more likely to be flagged as potential trafficking by FNS' fraud detection system. Trafficking is... many first-time users do not understand how to use the card and a grace period in the beginning would...
1988-11-01
264 ANALYSIS RESTART. ............. ..... ....... 269 1.0 TITLE CARD. .............. ............. 271 2.0 CONTROL CARDS...stress soil model will provide a tool for such analysis of waterfront structures. To understand the significance of liquefaction, it is important to note...Implementing this effective stress soil model into a finite element computer program would allow analysis of soil and structure together. TECHNICAL BACKGROUND
What Makes Responses Prepotent for Young Children? Insights from the Grass-Snow Task
ERIC Educational Resources Information Center
Simpson, Andrew; Riggs, Kevin J.
2009-01-01
Understanding how responses become prepotent is essential for understanding when inhibitory control is needed in everyday behaviour. We investigated prepotency in the grass-snow task--in which a child points to a green card when the experimenter says "snow" and a white card when the experimenter says "grass". Experiment 1 (n =…
Evaluation of four automated protocols for extraction of DNA from FTA cards.
Stangegaard, Michael; Børsting, Claus; Ferrero-Miliani, Laura; Frank-Hansen, Rune; Poulsen, Lena; Hansen, Anders J; Morling, Niels
2013-10-01
Extraction of DNA using magnetic bead-based techniques on automated DNA extraction instruments provides a fast, reliable, and reproducible method for DNA extraction from various matrices. Here, we have compared the yield and quality of DNA extracted from FTA cards using four automated extraction protocols on three different instruments. The extraction processes were repeated up to six times with the same pieces of FTA cards. The sample material on the FTA cards was either blood or buccal cells. With the QIAamp DNA Investigator and QIAsymphony DNA Investigator kits, it was possible to extract DNA from the FTA cards in all six rounds of extractions in sufficient amount and quality to obtain complete short tandem repeat (STR) profiles on a QIAcube and a QIAsymphony SP. With the PrepFiler Express kit, almost all the extractable DNA was extracted in the first two rounds of extractions. Furthermore, we demonstrated that it was possible to successfully extract sufficient DNA for STR profiling from previously processed FTA card pieces that had been stored at 4 °C for up to 1 year. This showed that rare or precious FTA card samples may be saved for future analyses even though some DNA was already extracted from the FTA cards.
"InFection Four": Development of a Youth-Informed Sexual Health Card Game
ERIC Educational Resources Information Center
Gilliam, Melissa; Jagoda, Patrick; Heathcock, Stephen; Sutherland, Ainsley
2014-01-01
Games may be useful tools for learning and communicating about sexual and reproductive health. This article discusses the collaborative design and subsequent evaluation of a narrative-based card game. This game was created in a workshop based on positive youth development, which allowed youth to be involved as game designers and game players.…
NOD2/CARD15 mutations and the risk of reoperation in patients with Crohns disease.
Martínek, L; Kupka, T; Simova, J; Klvaňa, P; Bojková, M; Uvírová, M; Dítě, P; Dvorackova, J; Hoch, J; Zonca, P
2015-06-01
Three NOD2/CARD15 gene variants (3020insC, R702W, G908R) have been identified as genetic risk factors for Crohns disease patients. However the diagnostic and therapeutic relevance for clinical practice remains limited. The aim of this study was to evaluate the association between these variants, the risk of reoperation and disease phenotype. In 76 Crohns disease patients (41 female, 35 male) with a minimum 5 year follow-up, three polymorphisms of the NOD2/CARD15 gene (R702W, G908R, 3020insC) were tested. Detailed clinical and medical history including surgical procedures and reoperations were obtained by reviewing the medical charts and completed prospectively. Association between the need for reoperation, disease phenotypes and gene variants were analyzed. 24 patients (32%) showed at least one NOD2/CARD15 mutation. 25 patients (33%) required reoperation, 51 (67%) represented the control group. The expected trend that patients with NOD2/CARD15 variants have a higher frequency of reoperations was not confirmed to a level of statistical significance (p=0.2688). Two of the four patients (50%) with the 3020insC variant required further surgery. We did not confirm any association between NOD2/CARD15 mutations and age at diagnosis (p=0.4356), behavior (p=0.6610), or localization (p=0.4747) according to the Montreal classification. NOD2/CARD15 polymorphisms did not significantly affect the reoperation rate. Homozygosity for the 3020insC variant in the NOD2/CARD15 gene is associated with a high risk of reoperation. NOD2/CARD15 gene variants are not significantly associated with specific disease phenotypes.
Computer soundcard as an AC signal generator and oscilloscope for the physics laboratory
NASA Astrophysics Data System (ADS)
Sinlapanuntakul, Jinda; Kijamnajsuk, Puchong; Jetjamnong, Chanthawut; Chotikaprakhan, Sutharat
2018-01-01
The purpose of this paper is to develop both an AC signal generator and a dual-channel oscilloscope based on standard personal computer equipped with sound card as parts of the laboratory of the fundamental physics and the introduction to electronics classes. The setup turns the computer into the two channel measured device which can provides sample rate, simultaneous sampling, frequency range, filters and others essential capabilities required to perform amplitude, phase and frequency measurements of AC signal. The AC signal also generate from the same computer sound card output simultaneously in any waveform such as sine, square, triangle, saw-toothed pulsed, swept sine and white noise etc. These can convert an inexpensive PC sound card into powerful device, which allows the students to measure physical phenomena with their own PCs either at home or at university attendance. A graphic user interface software was developed for control and analysis, including facilities for data recording, signal processing and real time measurement display. The result is expanded utility of self-learning for the students in the field of electronics both AC and DC circuits, including the sound and vibration experiments.
McKinney, Cushla; Stamp, Lisa K; Dalbeth, Nicola; Topless, Ruth K; Day, Richard O; Kannangara, Diluk Rw; Williams, Kenneth M; Janssen, Matthijs; Jansen, Timothy L; Joosten, Leo A; Radstake, Timothy R; Riches, Philip L; Tausche, Anne-Kathrin; Lioté, Frederic; So, Alexander; Merriman, Tony R
2015-10-13
The acute gout flare results from a localised self-limiting innate immune response to monosodium urate (MSU) crystals deposited in joints in hyperuricaemic individuals. Activation of the caspase recruitment domain-containing protein 8 (CARD8) NOD-like receptor pyrin-containing 3 (NLRP3) inflammasome by MSU crystals and production of mature interleukin-1β (IL-1β) is central to acute gouty arthritis. However very little is known about genetic control of the innate immune response involved in acute gouty arthritis. Therefore our aim was to test functional single nucleotide polymorphism (SNP) variants in the toll-like receptor (TLR)-inflammasome-IL-1β axis for association with gout. 1,494 gout cases of European and 863 gout cases of New Zealand (NZ) Polynesian (Māori and Pacific Island) ancestry were included. Gout was diagnosed by the 1977 ARA gout classification criteria. There were 1,030 Polynesian controls and 10,942 European controls including from the publicly-available Atherosclerosis Risk in Communities (ARIC) and Framingham Heart (FHS) studies. The ten SNPs were either genotyped by Sequenom MassArray or by Affymetrix SNP array or imputed in the ARIC and FHS datasets. Allelic association was done by logistic regression adjusting by age and sex with European and Polynesian data combined by meta-analysis. Sample sets were pooled for multiplicative interaction analysis, which was also adjusted by sample set. Eleven SNPs were tested in the TLR2, CD14, IL1B, CARD8, NLRP3, MYD88, P2RX7, DAPK1 and TNXIP genes. Nominally significant (P < 0.05) associations with gout were detected at CARD8 rs2043211 (OR = 1.12, P = 0.007), IL1B rs1143623 (OR = 1.10, P = 0.020) and CD14 rs2569190 (OR = 1.08; P = 0.036). There was significant multiplicative interaction between CARD8 and IL1B (P = 0.005), with the IL1B risk genotype amplifying the risk effect of CARD8. There is evidence for association of gout with functional variants in CARD8, IL1B and CD14. The gout-associated allele of IL1B increases expression of IL-1β - the multiplicative interaction with CARD8 would be consistent with a synergy of greater inflammasome activity (resulting from reduced CARD8) combined with higher levels of pre-IL-1β expression leading to increased production of mature IL-1β in gout.
Hall-Mendelin, Sonja; Hewitson, Glen R; Genge, Doris; Burtonclay, Peter J; De Jong, Amanda J; Pyke, Alyssa T; van den Hurk, Andrew F
2017-05-01
AbstractThe utility of applying infected Aedes aegypti to Flinders Technology Associates (FTA ® ) cards for storage, transport, and detection of dengue, Zika, and Barmah Forest viruses was assessed in laboratory-based experiments. The mosquitoes had been removed from Gravid Aedes Traps maintained under conditions of high temperature and humidity. RNA of all viruses could be detected in infected mosquitoes on FTA cards either individually or in pools with uninfected mosquitoes, and stored for up to 28 days. Importantly, there was only a minimal decrease in RNA levels in mosquitoes between days 0 and 28, indicating that viral RNA was relatively stable on the cards. FTA cards thus provide a mechanism for storing potentially infected mosquitoes collected in the field and transporting them to a central diagnostic facility for virus detection.
Hall-Mendelin, Sonja; Hewitson, Glen R.; Genge, Doris; Burtonclay, Peter J.; De Jong, Amanda J.; Pyke, Alyssa T.; van den Hurk, Andrew F.
2017-01-01
The utility of applying infected Aedes aegypti to Flinders Technology Associates (FTA®) cards for storage, transport, and detection of dengue, Zika, and Barmah Forest viruses was assessed in laboratory-based experiments. The mosquitoes had been removed from Gravid Aedes Traps maintained under conditions of high temperature and humidity. RNA of all viruses could be detected in infected mosquitoes on FTA cards either individually or in pools with uninfected mosquitoes, and stored for up to 28 days. Importantly, there was only a minimal decrease in RNA levels in mosquitoes between days 0 and 28, indicating that viral RNA was relatively stable on the cards. FTA cards thus provide a mechanism for storing potentially infected mosquitoes collected in the field and transporting them to a central diagnostic facility for virus detection. PMID:28500814
Conveying population education through games.
1987-01-01
Games are extremely useful for conveying population education messages because they are entertaining, because they involve the players in the learning situation, and because, by compressing space and time, they enable the players to perceive the effects of future events on their own lives. One teaching game, called "Futures Wheel," enables the players to move step by step from an abstract real-world situation to its impact on their own lives. Another game, called "Card Game on Family Welfare," is played by 4 players using cards illustrating such things as preparation for marriage, planned families, small families, responsible parenthood, and women's roles. 24 of the 25 cards dealt to the players have matching pictures on a base sheet. The player who loses, i.e., cannot find a match for his last card, is holding the card which displays an unhappy big family.
CARD15 Gene Polymorphisms Are Associated with Tuberculosis Susceptibility in Chinese Holstein Cows
Liu, Tong; Tu, Wenji; Li, Wengui; Dong, Guodong; Xu, Cong; Qin, Bo; Liu, Kaihua; Yang, Jie; Chai, Jun; Shi, Xianwei; Zhang, Yifang
2015-01-01
Bovine tuberculosis (BTB) is a significant veterinary and financial problem in many parts of the world. Associations between specific host genes and susceptibility to mycobacterial infections, such as tuberculosis, have been reported in several species. The objective of this study was to identify and evaluate the relationship of single-nucleotide polymorphisms (SNPs) in the CARD15 gene with susceptibility to BTB in Chinese Holstein cows. DNA samples from 201 Chinese Holstein cows (103 cases and 98 controls) were collected from Kunming City, Yuxi City, and Dali City in China. SNPs in the CARD15 gene were assessed using polymerase chain reaction (PCR) and restriction fragment length polymorphism-polymerase chain reaction (RFLP-PCR). Case-control association testing and statistical analysis identified six SNPs associated with susceptibility to BTB in Chinese Holstein cows. The frequency of genotypes C/T, A/G, A/G, A/G, C/T, and A/G in E4 (-37), 208, 1644, 1648, 1799, and E10 (+107), respectively, was significantly higher in cases than in controls, and also the alleles C, A, A, G, T, and A, respectively, were associated with a greater relative risk in cases than in controls. The distribution of two haplotypes, TGGACA and CAGACA, was significantly different between cases and controls. Overall, this case-control study suggested that E4 (-37)(C/T), 208(A/G), 1644(A/G), 1648(A/G), 1799(C/T), and E10 (+107)(A/G) in the CARD15 gene were significantly associated with susceptibility to BTB in Chinese Holstein cows and that haplotypes TGGACA and CAGACA could be used as genetic markers in marker-assisted breeding programs for breeding cows with high resistance to BTB. PMID:26244859
Weiss, Ingrid; Stepanovic, Serena; Chinyemba, Ulembe; Bateman, Jessica; Hemminger, Carolyn; Burrows, Emily
2016-01-01
The U.S. Agency for International Development Feed the Future Mawa Project – led by Catholic Relief Services – aims to improve food and economic security for farming households in Zambia’s Eastern Province. Mawa employs social and behavior change (SBC) strategies with households and communities to improve nutrition and reduce stunting among children under two (CU2). To support these strategies, sub-partner University Research Co., LLC employed a participatory process to develop a series of 35 action cards, each illustrating one project-promoted behavior, that are used at household and community group levels. Caregivers of CU2 are given a full set of action cards to promote household dialogue and support for the promoted behaviors. As a final step in the action card tool development process, a qualitative rapid assessment was conducted 1 month after implementation to investigate preliminary ways action cards were being used, and if the methods of using the cards had the potential to impact behavior change. The research team conducted nine key informant interviews and four focus group discussions with Mawa staff and administered 41 qualitative interview questionnaires with project participants in the Chipata and Lundazi districts. Although not based on a representative sampling frame, the assessment produced valuable results for program improvement purposes. It also provided a feedback mechanism for community-based staff and project participants, a crucial step in the participatory tool development process. The assessment found that Mawa staff at every level use action cards combined with at least one other social behavior change tool for each nutrition intervention. Our results suggest that Mawa staff and project participants share a common understanding of the cards’ purpose. Each group noted that the cards provide a visual cue for action and reinforce previous Mawa nutrition messages. Intended uses confirmed by the assessment include encouraging household cooperation, negotiating behavior change, telling stories, and integrating messages with other project sectors. Based on the findings, recommendations for future project activities include aligning efforts against a theory of change to optimize use of all SBC tools; leveraging action card use to strengthen cross-sectoral integration within Mawa; and specific ongoing monitoring of action card use to improve activity implementation. PMID:27630980
Messina, Bruna; Fuentes, Daniel; Tavares, Hermano; Abdo, Carmita H N; Scanavino, Marco de T
2017-03-01
Despite the serious behavioral consequences faced by individuals with sexual compulsivity, related neuropsychological studies are sparse. To compare decision making and cognitive flexibility at baseline and after exposure to an erotic video in sexually compulsive participants and non-sexually compulsive controls. The sample consisted of 30 sexually compulsive men and 30 controls. Cognitive flexibility was investigated through the Wisconsin Card Sorting Test and decision making was examined through the Iowa Gambling Task. Wisconsin Card Sorting Test categories, correct responses, and perseverative errors and Iowa Gambling Task general trends and blocks. Sexually compulsive subjects and controls performed similarly at baseline. After watching an erotic video, controls performed better in block 1 of the Iowa Gambling Task (P = .01) and had more correct responses on the Wisconsin Card Sorting Test (P = .01). The controls presented fewer impulsive initial choices and better cognitive flexibility after exposure to erotic stimuli. Messina B, Fuentes D, Tavares H, et al. Executive Functioning of Sexually Compulsive and Non-Sexually Compulsive Men Before and After Watching an Erotic Video. J Sex Med 2017;14:347-354. Copyright © 2017. Published by Elsevier Inc.
Biswal, Jitendra K; Subramaniam, Saravanan; Ranjan, Rajeev; Pattnaik, Bramhadev
2016-08-01
Foot-and-mouth disease (FMD) is a highly contagious epidemic disease of transboundary importance. Inadequate storage and shipment of suspected clinical samples can compromise the ability to detect and characterise FMD virus (FMDV) in endemic countries, thereby, leading to the loss of valuable virological and epidemiological data. This study, investigates the potential of using FTA(®) cards for dry transportation of clinical samples and subsequent recovery of infectious FMDV by chemical transfection of FTA(®) card fixed RNA as an alternative to the conventional cell culture based virus isolation method. A higher proportion of infectious FMDV was rescued from clinical samples (cell culture isolates, tongue epithelial suspension and impression smears) by the FTA(®) card fixed RNA transfection method (76%) compared to the conventional cell culture based virus isolation (56%), suggesting a better performance of the current RNA transfection procedure. Furthermore, it was possible to rescue live virus by the transfection of RNA extracted from FTA(®) card impregnated with clinical samples that had been stored at varying temperature (4-37 °C) up to a period of six weeks. The VP1 sequence data and antigenic relationships with the vaccine strains, between viruses rescued by FTA(®) card fixed RNA transfection and conventional cell culture, were comparable. Therefore, these results support the use of the FTA(®) card for the economic, dry, non-hazardous transport of FMD suspected clinical samples from the site of collection to national/international reference laboratories. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Hall, William A. (Inventor)
1993-01-01
A bus programmable slave module card for use in a computer control system is disclosed which comprises a master computer and one or more slave computer modules interfacing by means of a bus. Each slave module includes its own microprocessor, memory, and control program for acting as a single loop controller. The slave card includes a plurality of memory means (S1, S2...) corresponding to a like plurality of memory devices (C1, C2...) in the master computer, for each slave memory means its own communication lines connectable through the bus with memory communication lines of an associated memory device in the master computer, and a one-way electronic door which is switchable to either a closed condition or a one-way open condition. With the door closed, communication lines between master computer memory (C1, C2...) and slave memory (S1, S2...) are blocked. In the one-way open condition invention, the memory communication lines or each slave memory means (S1, S2...) connect with the memory communication lines of its associated memory device (C1, C2...) in the master computer, and the memory devices (C1, C2...) of the master computer and slave card are electrically parallel such that information seen by the master's memory is also seen by the slave's memory. The slave card is also connectable to a switch for electronically removing the slave microprocessor from the system. With the master computer and the slave card in programming mode relationship, and the slave microprocessor electronically removed from the system, loading a program in the memory devices (C1, C2...) of the master accomplishes a parallel loading into the memory devices (S1, S2...) of the slave.
Kuwawenaruwa, August; Mtei, Gemini; Baraka, Jitihada; Tani, Kassimu
2016-11-18
Inequity in access and use of child and maternal health services is impeding progress towards reduction of maternal mortality in low-income countries. To address low usage of maternal and newborn health care services as well as financial protection of families, some countries have adopted demand-side financing. In 2010, Tanzania introduced free health insurance cards to pregnant women and their families to influence access, use, and provision of health services. However, little is known about whether the use of the maternal and child health cards improved equity in access and use of maternal and child health care services. A mixed methods approach was used in Rungwe district where maternal and child health insurance cards had been implemented. To assess equity, three categories of beneficiaries' education levels were used and were compared to that of women of reproductive age in the region from previous surveys. To explore factors influencing women's decisions on delivery site and use of the maternal and child health insurance card and attitudes towards the birth experience itself, a qualitative assessment was conducted at representative facilities at the district, ward, facility, and community level. A total of 31 in-depth interviews were conducted on women who delivered during the previous year and other key informants. Women with low educational attainment were under-represented amongst those who reported having received the maternal and child health insurance card and used it for facility delivery. Qualitative findings revealed that problems during the current pregnancy served as both a motivator and a barrier for choosing a facility-based delivery. Decision about delivery site was also influenced by having experienced or witnessed problems during previous birth delivery and by other individual, financial, and health system factors, including fines levied on women who delivered at home. To improve equity in access to facility-based delivery care using strategies such as maternal and child health insurance cards is necessary to ensure beneficiaries and other stakeholders are well informed of the programme, as giving women insurance cards only does not guarantee facility-based delivery.
Bhattacharya, D; Bhattacharya, R; Dhar, T K
1999-11-19
In an earlier communication we have described a novel signal amplification technology termed Super-CARD, which is able to significantly improve antigen detection sensitivity in conventional Dot-ELISA by approximately 10(5)-fold. The method utilizes hitherto unreported synthesized electron rich proteins containing multiple phenolic groups which, when immobilized over a solid phase as blocking agent, markedly increases the signal amplification capability of the existing CARD method (Bhattacharya, R., Bhattacharya, D., Dhar, T.K., 1999. A novel signal amplification technology based on catalyzed reporter deposition and its application in a Dot-ELISA with ultra high sensitivity. J. Immunol. Methods 227, 31.). In this paper we describe the utilization of this Super-CARD amplification technique in ELISA and its applicability for the rapid determination of aflatoxin B(1) (AFB(1)) in infected seeds. Using this method under identical conditions, the increase in absorbance over the CARD method was approximately 400%. The limit of detection of AFB(1) by this method was 0.1 pg/well, the sensitivity enhancement being 5-fold over the optimized CARD ELISA. Furthermore, the total incubation time was reduced to 16 min compared to 50 min for the CARD method. Assay specificity was not adversely affected and the amount of AFB(1) measured in seed extracts correlated well with the values obtained by conventional ELISA.
An Approach to Near Field Data Selection in Radio Frequency Identification
NASA Astrophysics Data System (ADS)
Winkworth, Robert D.
Personal identification is needed in many civil activities, and the common identification cards, such as a driver's license, have become the standard document de facto. Radio frequency identification has complicated this matter. Unlike their printed predecessors, contemporary RFID cards lack a practical way for users to control access to their individual fields of data. This leaves them more available to unauthorized parties, and more prone to abuse. Here, then was undertaken a means to test a novel RFID card technology that allows overlays to be used for reliable, reversible data access settings. Similar to other proposed switching mechanisms, it offers advantages that may greatly improve outcomes. RFID use is increasing in identity documents such as drivers' licenses and passports, and with it concern over the theft of personal information, which can enable unauthorized tracking or fraud. Effort put into designing a strong foundation technology now may allow for widespread development on them later. In this dissertation, such a technology was designed and constructed, to drive the central thesis that selective detuning could serve as a feasible, reliable mechanism. The concept had been illustrated effective in limiting access to all fields simultaneously before, and was here effective in limiting access to specific fields selectively. A novel card was produced in familiar dimensions, with an intuitive interface by which users may conceal the visible print of the card to conceal the wireless emissions it allows. A discussion was included of similar technologies, involving capacitive switching, that could further improve the outcomes if such a product were put to large-scale commercial fabrication. The card prototype was put to a battery of laboratory tests to measure the degree of independence between data fields and the reliability of the switching mechanism when used under realistically variable coverage, demonstrating statistically consistent performance in both. The success rate of RFID card read operations, which are already greater than 99.9%, were exceeded by the success rate of selection using the featured technology. With controls in place for the most influential factors related to card readability (namely the distance from the reader antennas and the orientation of the card antenna with respect to them), the card was shown to completely resist data acquisition from unauthorized fields while allowing unimpeded access to authorized fields, even after thousands of varied attempts. The effect was proven to be temporary and reversible. User intervention allowed for the switching to occur in a matter of seconds by sliding a conductive sleeve or applying tape to regions of the card. Strategies for widespread implementation were discussed, emphasizing factors that included cost, durability, size, simplicity, and familiarity, all of which arise in card management decisions for common state and national identification such as a driver's license. The relationship between the card and external database systems was detailed, as no such identification document could function in isolation. A practical solution involving it will include details of how multiple fields will be written to the card and separated sufficiently in external databases so as to allow for user-directed selection of data field disclosure. Opportunities for implementation in corporate and academic environments were discussed, along with the ways in which this technology could invite further investigation.
Cortes, Aneg L; Montiel, Enrique R; Gimeno, Isabel M
2009-12-01
The use of Flinders Technology Associates (FTA) filter cards to quantify Marek's disease virus (MDV) DNA for the diagnosis of Marek's disease (MD) and to monitor MD vaccines was evaluated. Samples of blood (43), solid tumors (14), and feather pulp (FP; 36) collected fresh and in FTA cards were analyzed. MDV DNA load was quantified by real-time PCR. Threshold cycle (Ct) ratios were calculated for each sample by dividing the Ct value of the internal control gene (glyceraldehyde-3-phosphate dehydrogenase) by the Ct value of the MDV gene. Statistically significant correlation (P < 0.05) within Ct ratios was detected between samples collected fresh and in FTA cards by using Pearson's correlation test. Load of serotype 1 MDV DNA was quantified in 24 FP, 14 solid tumor, and 43 blood samples. There was a statistically significant correlation between FP (r = 0.95), solid tumor (r = 0.94), and blood (r = 0.9) samples collected fresh and in FTA cards. Load of serotype 2 MDV DNA was quantified in 17 FP samples, and the correlation between samples collected fresh and in FTA cards was also statistically significant (Pearson's coefficient, r = 0.96); load of serotype 3 MDV DNA was quantified in 36 FP samples, and correlation between samples taken fresh and in FTA cards was also statistically significant (r = 0.84). MDV DNA samples extracted 3 days (t0) and 8 months after collection (t1) were used to evaluate the stability of MDV DNA in archived samples collected in FTA cards. A statistically significant correlation was found for serotype 1 (r = 0.96), serotype 2 (r = 1), and serotype 3 (r = 0.9). The results show that FTA cards are an excellent media to collect, transport, and archive samples for MD diagnosis and to monitor MD vaccines. In addition, FTA cards are widely available, inexpensive, and adequate for the shipment of samples nationally and internationally.
Programmable data communications controller requirements
NASA Technical Reports Server (NTRS)
1977-01-01
The design requirements for a Programmable Data Communications Controller (PDCC) that reduces the difficulties in attaching data terminal equipment to a computer are presented. The PDCC is an interface between the computer I/O channel and the bit serial communication lines. Each communication line is supported by a communication port that handles all line control functions and performs most terminal control functions. The port is fabricated on a printed circuit board that plugs into a card chassis, mating with a connector that is joined to all other card stations by a data bus. Ports are individually programmable; each includes a microprocessor, a programmable read-only memory for instruction storage, and a random access memory for data storage.
NASA Technical Reports Server (NTRS)
Hill, R. W.
1994-01-01
The integration of CLIPS into HyperCard combines the intuitive, interactive user interface of the Macintosh with the powerful symbolic computation of an expert system interpreter. HyperCard is an excellent environment for quickly developing the front end of an application with buttons, dialogs, and pictures, while the CLIPS interpreter provides a powerful inference engine for complex problem solving and analysis. In order to understand the benefit of integrating HyperCard and CLIPS, consider the following: HyperCard is an information storage and retrieval system which exploits the use of the graphics and user interface capabilities of the Apple Macintosh computer. The user can easily define buttons, dialog boxes, information templates, pictures, and graphic displays through the use of the HyperCard tools and scripting language. What is generally lacking in this environment is a powerful reasoning engine for complex problem solving, and this is where CLIPS plays a role. CLIPS 5.0 (C Language Integrated Production System, v5.0) was developed at the Johnson Space Center Software Technology Branch to allow artificial intelligence research, development, and delivery on conventional computers. CLIPS 5.0 supports forward chaining rule systems, object-oriented language, and procedural programming for the construction of expert systems. It features incremental reset, seven conflict resolution stategies, truth maintenance, and user-defined external functions. Since CLIPS is implemented in the C language it is highly portable; in addition, it is embeddable as a callable routine from a program written in another language such as Ada or Fortran. By integrating HyperCard and CLIPS the advantages and uses of both packages are made available for a wide range of applications: rapid prototyping of knowledge-based expert systems, interactive simulations of physical systems and intelligent control of hypertext processes, to name a few. HyperCLIPS 2.0 is written in C-Language (54%) and Pascal (46%) for Apple Macintosh computers running Macintosh System 6.0.2 or greater. HyperCLIPS requires HyperCard 1.2 or higher and at least 2Mb of RAM are recommended to run. An executable is provided. To compile the source code, the Macintosh Programmer's Workshop (MPW) version 3.0, CLIPS 5.0 (MSC-21927), and the MPW C-Language compiler are also required. NOTE: Installing this program under Macintosh System 7 requires HyperCard v2.1. This program is distributed on a 3.5 inch Macintosh format diskette. A copy of the program documentation is included on the diskette, but may be purchased separately. HyperCLIPS was developed in 1990 and version 2.0 was released in 1991. HyperCLIPS is a copyrighted work with all copyright vested in NASA. Apple, Macintosh, MPW, and HyperCard are registered trademarks of Apple Computer, Inc.
How to create successful Open Hardware projects — About White Rabbits and open fields
NASA Astrophysics Data System (ADS)
van der Bij, E.; Arruat, M.; Cattin, M.; Daniluk, G.; Gonzalez Cobas, J. D.; Gousiou, E.; Lewis, J.; Lipinski, M. M.; Serrano, J.; Stana, T.; Voumard, N.; Wlostowski, T.
2013-12-01
CERN's accelerator control group has embraced ''Open Hardware'' (OH) to facilitate peer review, avoid vendor lock-in and make support tasks scalable. A web-based tool for easing collaborative work was set up and the CERN OH Licence was created. New ADC, TDC, fine delay and carrier cards based on VITA and PCI-SIG standards were designed and drivers for Linux were written. Often industry was paid for developments, while quality and documentation was controlled by CERN. An innovative timing network was also developed with the OH paradigm. Industry now sells and supports these designs that find their way into new fields.
A security and privacy preserving e-prescription system based on smart cards.
Hsu, Chien-Lung; Lu, Chung-Fu
2012-12-01
In 2002, Ateniese and Medeiros proposed an e-prescription system, in which the patient can store e-prescription and related information using smart card. Latter, Yang et al. proposed a novel smart-card based e-prescription system based on Ateniese and Medeiros's system in 2004. Yang et al. considered the privacy issues of prescription data and adopted the concept of a group signature to provide patient's privacy protection. To make the e-prescription system more realistic, they further applied a proxy signature to allow a patient to delegate his signing capability to other people. This paper proposed a novel security and privacy preserving e-prescription system model based on smart cards. A new role, chemist, is included in the system model for settling the medicine dispute. We further presented a concrete identity-based (ID-based) group signature scheme and an ID-based proxy signature scheme to realize the proposed model. Main property of an ID-based system is that public key is simple user's identity and can be verified without extra public key certificates. Our ID-based group signature scheme can allow doctors to sign e-prescription anonymously. In a case of a medical dispute, identities of the doctors can be identified. The proposed ID-based proxy signature scheme can improve signing delegation and allows a delegation chain. The proposed e-prescription system based on our proposed two cryptographic schemes is more practical and efficient than Yang et al.'s system in terms of security, communication overheads, computational costs, practical considerations.
ERIC Educational Resources Information Center
Bayne, Pauline S; Rader, Joe C.
The purpose of this project was to demonstrate that computer-based training (CBT) sessions, produced as HyperCard stacks (files), are an efficient and effective component for staff training in libraries. The purpose was successfully met in the 15-month period of development, evaluation, and implementation, and the University of Tennessee (UT)…
ERIC Educational Resources Information Center
Mathena, Ann Ashley
2017-01-01
The purpose of this transcendental, phenomenological study was to understand the impact of online grading and standards-based report cards on elementary teacher instruction at a suburban school system. This research study examined teacher instruction and assessment, sharing obstacles, and resources necessary for the effective use of…
Training and Maintenance of a Picture-Based Communication Response in Older Adults with Dementia
ERIC Educational Resources Information Center
Trahan, Maranda A.; Donaldson, Jeanne M.; McNabney, Matthew K.; Kahng, SungWoo
2014-01-01
We examined whether adults with dementia could learn to emit a picture-based communication response and if this skill would maintain over time. Three women with moderate to severe dementia were taught to exchange a picture card for a highly preferred activity. All participants quickly learned to exchange the picture card and maintained this…
Implementation and comparative study of control strategies for an isolated DFIG based WECS
NASA Astrophysics Data System (ADS)
Bouchiba, Nouha; Barkia, Asma; Sallem, Souhir; Chrifi-Alaoui, Larbi; Drid, Saïd; Kammoun, M. B. A.
2017-10-01
Nowadays, a global interest for renewable energy sources has been growing intensely. In particular, a wind energy has become the most popular. In case of autonomous systems, wind energy conversion system (WECS) based on a double fed induction generator (DFIG) is widely used. In this paper, in order to control the stand-alone system outputs under wind speed and load variations, three kinds of nonlinear control strategies have been proposed, applied and compared, such as: Classical PI controller, Back-Stepping and Sliding Mode controllers. A series of experiments have been conducted to evaluate and to compare the developed controllers' dynamic performances under load demand and speed variations. The design and the implementation of different control strategies to a 1.5kW doubly fed induction machine is carried out using a dSpace DS1104 card based on MATLAB/Simulink environment. Experimental results are presented to show the validity of the implemented controllers and demonstrate the effectiveness of each controller compared with others.
2011-04-30
fielding, contracting, interoperability, organizational behavior, risk management , cost estimating, and many others. Approaches range from... COSO ), (Whittington & Pany, 2012). In addition, the Federal Financial Management Improvement Act of 1996 identified internal control as an...fraud indicators within the DoD Government Purchase Card Programs and provides recommendations for improving the management of Government Purchase
Code of Federal Regulations, 2011 CFR
2011-01-01
... CONTROL (REGULATION Y) Pt. 225, App. D Appendix D to Part 225—Capital Adequacy Guidelines for Bank Holding..., nonmortgage servicing assets, and purchased credit card relationships that, in the aggregate, are in excess of 100 percent of Tier 1 capital; amounts of nonmortgage servicing assets and purchased credit card...
Statistical Tools for Determining Fitness to Fly
1981-09-01
program. (a) Number of Cards in file: 13 (b) Layout of Card 1: iIi Field Length a•e. Variable 1 8 Real EFAIL : Average # of failures for size of control...Method Compute Survival Probability and Frequency Tables 4-4 END 25P FLUW CHARTS 27 QSTART Input EFAIL ,CYEAR,NVAR,NAV,XINC BB~i i=1,3 name (1) i=1,4 Call
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-12
...: Statement Regarding a Lost or Stolen U.S. Passport Book and/or Card ACTION: Notice of request for public... Collection: Statement Regarding a Lost or Stolen U.S. Passport Book and/or Card OMB Control Number: 1405-0014... Affairs, Passport Services, Office of Program Management and Operational Support, Program Coordination...
ERIC Educational Resources Information Center
Okpube, Nnaemeka Michael; Anugwo, M. N.
2016-01-01
This study investigated the Card Games and Algebra tic-Tacmatics on Junior Secondary II Students' Achievement in Algebraic Expressions. Three research questions and three null hypotheses guided the study. The study adopted the pre-test, post-test control group design. A total of two hundred and forty (240) Junior Secondary School II students were…
Hyperspectral imaging-based credit card verifier structure with adaptive learning.
Sumriddetchkajorn, Sarun; Intaravanne, Yuttana
2008-12-10
We propose and experimentally demonstrate a hyperspectral imaging-based optical structure for verifying a credit card. Our key idea comes from the fact that the fine detail of the embossed hologram stamped on the credit card is hard to duplicate, and therefore its key color features can be used for distinguishing between the real and counterfeit ones. As the embossed hologram is a diffractive optical element, we shine a number of broadband light sources one at a time, each at a different incident angle, on the embossed hologram of the credit card in such a way that different color spectra per incident angle beam are diffracted and separated in space. In this way, the center of mass of the histogram on each color plane is investigated by using a feed-forward backpropagation neural-network configuration. Our experimental demonstration using two off-the-shelf broadband white light emitting diodes, one digital camera, and a three-layer neural network can effectively identify 38 genuine and 109 counterfeit credit cards with false rejection rates of 5.26% and 0.92%, respectively. Key features include low cost, simplicity, no moving parts, no need of an additional decoding key, and adaptive learning.
A computer program to trace seismic ray distribution in complex two-dimensional geological models
Yacoub, Nazieh K.; Scott, James H.
1970-01-01
A computer program has been developed to trace seismic rays and their amplitudes and energies through complex two-dimensional geological models, for which boundaries between elastic units are defined by a series of digitized X-, Y-coordinate values. Input data for the program includes problem identification, control parameters, model coordinates and elastic parameter for the elastic units. The program evaluates the partitioning of ray amplitude and energy at elastic boundaries, computes the total travel time, total travel distance and other parameters for rays arising at the earth's surface. Instructions are given for punching program control cards and data cards, and for arranging input card decks. An example of printer output for a simple problem is presented. The program is written in FORTRAN IV language. The listing of the program is shown in the Appendix, with an example output from a CDC-6600 computer.
Tian, Maoyi; Ajay, Vamadevan S.; Dunzhu, Danzeng; Hameed, Safraj S.; Li, Xian; Liu, Zhong; Li, Cong; Chen, Hao; Cho, KaWing; Li, Ruilai; Zhao, Xingshan; Jindal, Devraj; Rawal, Ishita; Ali, Mohammed K.; Peterson, Eric D.; Ji, Jiachao; Amarchand, Ritvik; Krishnan, Anand; Tandon, Nikhil; Xu, Li-Qun; Wu, Yangfeng; Prabhakaran, Dorairaj; Yan, Lijing L.
2015-01-01
Background In rural areas in China and India, cardiovascular disease burden is high but economic and healthcare resources are limited. This study aims to develop and evaluate a simplified cardiovascular management program (SimCard) delivered by community health workers (CHWs) with the aid of a smartphone-based electronic decision support system. Methods and Results The SimCard study was a yearlong cluster-randomized controlled trial conducted in 47 villages (27 in China and 20 in India). 2,086 ‘high cardiovascular risk’ individuals (aged 40 years or older with self-reported history of coronary heart disease, stroke, diabetes, and/or measured systolic blood pressure ≥160 mmHg) were recruited. Participants in the intervention villages were managed by CHWs through an Android-powered “app” on a monthly basis focusing on two medication use and two lifestyle modifications. Compared with the control group, the intervention group had a 25.5% (P<0.001) higher net increase in the primary outcome of the proportion of patient-reported anti-hypertensive medication use pre-and-post intervention. There were also significant differences in certain secondary outcomes: aspirin use (net difference 17.1%, P<0.001) and systolic blood pressure (−2.7 mmHg, P=0.04). However, no significant changes were observed in the lifestyle factors. The intervention was culturally tailored and country-specific results revealed important differences between the regions. Conclusions The results indicate that the simplified cardiovascular management program improved quality of primary care and clinical outcomes in resource-poor settings in China and India. Larger trials in more places are needed to ascertain potential impacts on mortality and morbidity outcomes. Clinical Trial Registration Information clinicaltrials.gov. Identifier: NCT01503814. PMID:26187183
NASA Technical Reports Server (NTRS)
Baruah, P. K.; Bussoletti, J. E.; Chiang, D. T.; Massena, W. A.; Nelson, F. D.; Furdon, D. J.; Tsurusaki, K.
1981-01-01
The Maintenance Document is a guide to the PAN AIR software system, a system which computes the subsonic or supersonic linear potential flow about a body of nearly arbitrary shape, using a higher order panel method. The document describes the over-all system and each program module of the system. Sufficient detail is given for program maintenance, updating and modification. It is assumed that the reader is familiar with programming and CDC (Control Data Corporation) computer systems. The PAN AIR system was written in FORTRAN 4 language except for a few COMPASS language subroutines which exist in the PAN AIR library. Structured programming techniques were used to provide code documentation and maintainability. The operating systems accommodated are NOS 1.2, NOS/BE and SCOPE 2.1.3 on the CDC 6600, 7600 and Cyber 175 computing systems. The system is comprised of a data management system, a program library, an execution control module and nine separate FORTRAN technical modules. Each module calculates part of the posed PAN AIR problem. The data base manager is used to communicate between modules and within modules. The technical modules must be run in a prescribed fashion for each PAN AIR problem. In order to ease the problem of supplying the many JCL cards required to execute the modules, a separate module called MEC (Module Execution Control) was created to automatically supply most of the JCL cards. In addition to the MEC generated JCL, there is an additional set of user supplied JCL cards to initiate the JCL sequence stored on the system.
Increasing intention to cook from basic ingredients: A randomised controlled study.
Lavelle, Fiona; Hollywood, Lynsey; Caraher, Martin; McGowan, Laura; Spence, Michelle; Surgenor, Dawn; McCloat, Amanda; Mooney, Elaine; Raats, Monique; Dean, Moira
2017-09-01
The promotion of home cooking is a strategy used to improve diet quality and health. However, modern home cooking typically includes the use of processed food which can lead to negative outcomes including weight gain. In addition, interventions to improve cooking skills do not always explain how theory informed their design and implementation. The Behaviour Change Technique (BCT) taxonomy successfully employed in other areas has identified essential elements for interventions. This study investigated the effectiveness of different instructional modes for learning to cook a meal, designed using an accumulating number of BCTs, on participant's perceived difficulty, enjoyment, confidence and intention to cook from basic ingredients. 141 mothers aged between 20 and 39 years from the island of Ireland were randomised to one of four conditions based on BCTs (1) recipe card only [control condition]; (2) recipe card plus video modelling; (3) recipe card plus video prompting; (4) recipe card plus video elements. Participants rated their enjoyment, perceived difficulty, confidence and intention to cook again pre, mid and post experiment. Repeated one-way factorial ANOVAs, correlations and a hierarchical regression model were conducted. Despite no significant differences between the different conditions, there was a significant increase in enjoyment (P < 0.001), confidence (P < 0.001) and intention to cook from basics again (P < 0.001) and a decrease in perceived difficulty (P = 0.001) after the experiment in all conditions. Intention to cook from basics pre-experiment, and confidence and enjoyment (both pre and post experiment) significantly contributed to the final regression model explaining 42% of the variance in intention to cook from basics again. Cooking interventions should focus on practical cooking and increasing participants' enjoyment and confidence during cooking to increase intention to cook from basic ingredients at home. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Jordan, T. M.
1970-01-01
A description of the FASTER-III program for Monte Carlo Carlo calculation of photon and neutron transport in complex geometries is presented. Major revisions include the capability of calculating minimum weight shield configurations for primary and secondary radiation and optimal importance sampling parameters. The program description includes a users manual describing the preparation of input data cards, the printout from a sample problem including the data card images, definitions of Fortran variables, the program logic, and the control cards required to run on the IBM 7094, IBM 360, UNIVAC 1108 and CDC 6600 computers.
Managing medical and insurance information through a smart-card-based information system.
Lambrinoudakis, C; Gritzalis, S
2000-08-01
The continuously increased mobility of patients and doctors, in conjunction with the existence of medical groups consisting of private doctors, general practitioners, hospitals, medical centers, and insurance companies, pose significant difficulties on the management of patients' medical data. Inevitably this affects the quality of the health care services provided. The evolving smart card technology can be utilized for the implementation of a secure portable electronic medical record, carried by the patient herself/himself. In addition to the medical data, insurance information can be stored in the smart card thus facilitating the creation of an "intelligent system" supporting the efficient management of patient's data. In this paper we present the main architectural and functional characteristics of such a system. We also highlight how the security features offered by smart cards can be exploited in order to ensure confidentiality and integrity of the medical data stored in the patient cards.
Will hospital report cards make the grade?
1997-07-01
Hospital report cards that document patients' medical outcomes are attracting increasing attention for their role in guiding health care decisions by employers, consumers and providers. Significant questions remain, however, regarding the validity and utility of this information. This Issue Brief is based on a seminar held by the Center for Studying Health System Change at which two expert panels discussed whether report cards make the grade. The first panel approached this subject through a Socratic dialogue that focused on the release of a hypothetical community hospital report card. The second panel weighed in on two research presentations related to report cards. The panelists agreed that efforts to collect and report clinical outcomes data are flawed. Even so, release of the data can help improve clinical quality and foster an environment in which health care quality information ultimately has an impact on health care decision making.
Lalani, Tahaniyat; Tisdale, Michele D; Maguire, Jason D; Wongsrichanalai, Chansuda; Riddle, Mark S; Tribble, David R
2015-09-01
We evaluated the limits of detection (LoD) for an 11-plex PCR-Luminex assay performed on Whatman(™) FTA Elute cards smeared with stool containing pathogens associated with travelers' diarrhea. LoDs ranged from 10(2) to 10(5)CFU, PFU, or cysts/g for most pathogens except Cryptosporidium. Campylobacter and norovirus LoDs increased with prolonged storage of cards. Copyright © 2015 Elsevier Inc. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-06
... Denver, Colorado. Communication Manager is designed to run on a variety of Linux-based media servers.... Some servers are in the form of blades. These are cards (similar to printed circuit cards with...
Developing a High Level Data Base to Teach Reproductive Endocrinology Using the HyperCard Program.
ERIC Educational Resources Information Center
Friedler, Yael; Shabo, Amnon
1990-01-01
Describes a database courseware using the HyperCard program on the subject of human reproductive endocrinology and feedback mechanisms. Discusses some issues concerning database courseware development. Presents several examples of the courseware display. (Author/YP)
Peluso, A L; Cozzolino, I; Bottiglieri, A; Lucchese, L; Di Crescenzo, R M; Langella, M; Selleri, C; Zeppa, P
2017-06-01
To evaluate and compare the DNA yield and quality extracted from lymph node fine needle cytology (FNC) samples stored on FTA cards to those cryopreserved, and to assess the immunoglobulin heavy and light chains (IGHK) and T-Cell receptor beta and gamma chains (TCRBG) PCR tests. DNA extractions were performed on FNC of 80 non-Hodgkin lymphomas (NHL), four myelomas and 56 benign reactive hyperplasias (BRH) cryopreserved and stored on FTA cards. The JAK2 gene was amplified to assess the DNA integrity and the IGHK/TCRBG clonality status was tested. IGHK monoclonality was found in 99% of B-cell NHL and 100% of myeloma. TCRBG monoclonality was found in 100% of T-cell NHL. TCRBG polyclonality was detected in 97% of B-cell NHL, 100% of myeloma and 96% of BRH. IGHK/TCRBG PCR data were confirmed by histological and/or follow-up controls. No differences were found in the DNA quality between cryopreservation and FTA cards storage methods. IGHK/TCRBG PCR of the lymphoproliferative process on FTA cards is comparable to those cryopreserved. FTA cards can be used to store lymph node FNC for further molecular investigations. © 2016 John Wiley & Sons Ltd.
Health policy. Who's got the master card?
Robinson, Ray
2002-09-26
The last decade has seen huge shifts away from the command and control model which dominated health policy since the foundation of the NHS. The current Labour government Initially favoured a system based on collaboration and partnership working but the incentives to achieve this were not sufficiently strong. Competition is now once again openly cited as a driver for improved performance. Political demands mean that command and control are likely to remain key features of government health policy. But this, in turn, is likely to place major limitations on the local autonomy pledged by the government.
Melanson, Vanessa R; Jochim, Ryan; Yarnell, Michael; Ferlez, Karen Bingham; Shashikumar, Soumya; Richardson, Jason H
2017-01-01
Vector-borne pathogen surveillance programmes typically rely on the collection of large numbers of potential vectors followed by screening protocols focused on detecting pathogens in the arthropods. These processes are laborious, time consuming, expensive, and require screening of large numbers of samples. To streamline the surveillance process, increase sample throughput, and improve cost-effectiveness, a method to detect dengue virus and malaria parasites (Plasmodium falciparum) by leveraging the sugar-feeding behaviour of mosquitoes and their habit of expectorating infectious agents in their saliva during feeding was investigated in this study. Dengue virus 2 (DENV-2) infected female Aedes aegypti mosquitoes and P. falciparum infected female Anopheles stephensi mosquitoes were allowed to feed on honey coated Flinders Technical Associates -FTA® cards dyed with blue food colouring. The feeding resulted in deposition of saliva containing either DENV-2 particles or P. falciparum sporozoites onto the FTA card. Nucleic acid was extracted from each card and the appropriate real-time PCR (qPCR) assay was run to detect the pathogen of interest. As little as one plaque forming unit (PFU) of DENV-2 and as few as 60 P. falciparum parasites deposited on FTA cards from infected mosquitoes were detected via qPCR. Hence, their use to collect mosquito saliva for pathogen detection is a relevant technique for vector surveillance. This study provides laboratory confirmation that FTA cards can be used to capture and stabilize expectorated DENV-2 particles and P. falciparum sporozoites from infectious, sugar-feeding mosquitoes in very low numbers. Thus, the FTA card-based mosquito saliva capture method offers promise to overcome current limitations and revolutionize traditional mosquito-based pathogen surveillance programmes. Field testing and further method development are required to optimize this strategy.
Ben-Ari Fuchs, Shani; Lieder, Iris; Stelzer, Gil; Mazor, Yaron; Buzhor, Ella; Kaplan, Sergey; Bogoch, Yoel; Plaschkes, Inbar; Shitrit, Alina; Rappaport, Noa; Kohn, Asher; Edgar, Ron; Shenhav, Liraz; Safran, Marilyn; Lancet, Doron; Guan-Golan, Yaron; Warshawsky, David; Shtrichman, Ronit
2016-03-01
Postgenomics data are produced in large volumes by life sciences and clinical applications of novel omics diagnostics and therapeutics for precision medicine. To move from "data-to-knowledge-to-innovation," a crucial missing step in the current era is, however, our limited understanding of biological and clinical contexts associated with data. Prominent among the emerging remedies to this challenge are the gene set enrichment tools. This study reports on GeneAnalytics™ ( geneanalytics.genecards.org ), a comprehensive and easy-to-apply gene set analysis tool for rapid contextualization of expression patterns and functional signatures embedded in the postgenomics Big Data domains, such as Next Generation Sequencing (NGS), RNAseq, and microarray experiments. GeneAnalytics' differentiating features include in-depth evidence-based scoring algorithms, an intuitive user interface and proprietary unified data. GeneAnalytics employs the LifeMap Science's GeneCards suite, including the GeneCards®--the human gene database; the MalaCards-the human diseases database; and the PathCards--the biological pathways database. Expression-based analysis in GeneAnalytics relies on the LifeMap Discovery®--the embryonic development and stem cells database, which includes manually curated expression data for normal and diseased tissues, enabling advanced matching algorithm for gene-tissue association. This assists in evaluating differentiation protocols and discovering biomarkers for tissues and cells. Results are directly linked to gene, disease, or cell "cards" in the GeneCards suite. Future developments aim to enhance the GeneAnalytics algorithm as well as visualizations, employing varied graphical display items. Such attributes make GeneAnalytics a broadly applicable postgenomics data analyses and interpretation tool for translation of data to knowledge-based innovation in various Big Data fields such as precision medicine, ecogenomics, nutrigenomics, pharmacogenomics, vaccinomics, and others yet to emerge on the postgenomics horizon.
Sánchez, Juan Luis; Martín, Javier; López, Carolina
2017-12-01
The classic version of the Wisconsin Card Sorting Test (WCST) consists of correctly sorting 128 cards according to changing sorting criteria. Its application is costly in terms of the time employed, with all the negative consequences this entails (decrease in motivation, frustration, and fatigue). The main objective of this study was to test the usefulness of the shortened version of the WCST as compared to the full test by analyzing the equivalence between the two decks comprising the full 128-card version on a sample of patients diagnosed with sporadic late onset Alzheimer disease (SLOAD) and to check its clinical usefulness. The variables showed equivalence between the two decks and their ability to differentiate between the control group (CG) and the Alzheimer disease (AD) group. The scores obtained suggest equivalence between decks and that the application of only the first deck is sufficient.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bolton, N. E.; Ketchen, E. E.; Porter, W. E.
For large industrial and research operations, maintaining reasonable control of all toxic materials used in their operations can be a formidable task. A system utilizing cards has been developed that serves a dual purpose, informing the user regarding hazards of a particular material and also facilitating appropriate workplace surveillance during its use. Selected data, including threshold limit values, routes of absorption, symptoms of exposure, chronic effects, and emergency first-aid procedures, are printed on the card. A portion of the card contains the label that the user detaches and affixes to the container. This label classifies the material according to flammability,more » toxicity, reactivity, and special properties on a 0 through 4 hazard rating system. This report describes the development and use of such cards, contains the associated Toxic Material Data Sheets that provide full backup data for the labels, and furnishes a glossary of biomedical terms used in the Data Sheets.« less
An Experiment Support Computer for Externally-Based ISS Payloads
NASA Astrophysics Data System (ADS)
Sell, S. W.; Chen, S. E.
2002-01-01
The Experiment Support Facility - External (ESF-X) is a computer designed for general experiment use aboard the International Space Station (ISS) Truss Site locations. The ESF-X design is highly modular and uses commercial off-the-shelf (COTS) components wherever possible to allow for maximum reconfigurability to meet the needs of almost any payload. The ESF-X design has been developed with the EXPRESS Pallet as the target location and the University of Colorado's Micron Accuracy Deployment Experiment (MADE) as the anticipated first payload and capability driver. Thus the design presented here is configured for structural dynamics and control as well as optics experiments. The ESF-X is a small (58.4 x 48.3 x 17.8") steel and copper enclosure which houses a 14 slot VME card chassis and power supply. All power and data connections are made through a single panel on the enclosure so that only one side of the enclosure must be accessed for nominal operation and servicing activities. This feature also allows convenient access during integration and checkout activities. Because it utilizes a standard VME backplane, ESF-X can make use of the many commercial boards already in production for this standard. Since the VME standard is also heavily used in industrial and military applications, many ruggedized components are readily available. The baseline design includes commercial processors, Ethernet, MIL-STD-1553, and mass storage devices. The main processor board contains four TI 6701 DSPs with a PowerPC based controller. Other standard functions, such as analog-to-digital, digital-to-analog, motor driver, temperature readings, etc., are handled on industry-standard IP modules. Carrier cards, which hold 4 IP modules each, are placed in slots in the VME backplane. A unique, custom IP carrier board with radiation event detectors allows non RAD-hard components to be used in an extended exposure environment. Thermal control is maintained by conductive cooling through the copper floor of the enclosure. All components, including the VME backplane, are thermally connected to the floor. The VME chassis can accept both conduction-cooled and convection cooled cards; non-conduction-cooled cards are simply thermal-strapped to the VME chassis. The current ESF-X configuration provides 44 high-rate A/D, 48 low-rate temperature RTDs, 32 digital IO channels (DIO), as well as drivers for digital position encoders, video frame grabbers, an optical interferometry system, stepper motors, paraffin actuators, high torque DC brushless motors, and piezoelectric actuators based on capability demands derived from the MADE program. ESF-X is presently in the critical design phase; potential users are welcome to submit comments and capability requests.
General purpose PDP-11 interface processor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Purtilo, J.
1982-10-01
The Z80 interface card, which for simplicity we refer to as the Zcard, is a general purpose microprocessor which is directly interfaced to the Whaley multiplexor, itself implemented on PDP-11 series computers at the University of Illinois. The Zcard provides two serial ports at EAI interface levels and contains up to 16K of local memory. The principle function of the Zcard is to serve as an interface in which the user might alter protocols, change interface characteristics (e.g. baud rate, hardware echo, or flow control), or switch between synchronous and asynchronous modes all under software control. In addition, the Zcardmore » provides extra lines for control of external devices (e.g. modem) and input of status data. In the simpliest use, the Zcard runs a program, downloaded from the PDP-11, which emulates the level EIAFB card (previously developed for the Whaley Multiplexor) for serial communication with terminals. Using no flow control, Zcard performance seems superior to that of the EIAFB card in that no characters are lost under normal use (due to the much larger buffer which the Zcard can provide). The Zcard can further distinguish itself from the EIAFB card in that flow control can be enabled by software. A more sophisticated application of the Zcard might include linking several Zcards (using a synchronous option and both of the provided ports) into a network. In this capacity, a ring topology suggests itself as the most immediate choice, although many alternate connection schemes can be envisioned. This report is intended to summarize the project as well as provide an outline for those intending to modify or program the Zcard.« less
A Preliminary Study of Clinical Abbreviation Disambiguation in Real Time.
Wu, Y; Denny, J C; Rosenbloom, S T; Miller, R A; Giuse, D A; Song, M; Xu, H
2015-01-01
To save time, healthcare providers frequently use abbreviations while authoring clinical documents. Nevertheless, abbreviations that authors deem unambiguous often confuse other readers, including clinicians, patients, and natural language processing (NLP) systems. Most current clinical NLP systems "post-process" notes long after clinicians enter them into electronic health record systems (EHRs). Such post-processing cannot guarantee 100% accuracy in abbreviation identification and disambiguation, since multiple alternative interpretations exist. Authors describe a prototype system for real-time Clinical Abbreviation Recognition and Disambiguation (rCARD) - i.e., a system that interacts with authors during note generation to verify correct abbreviation senses. The rCARD system design anticipates future integration with web-based clinical documentation systems to improve quality of healthcare records. When clinicians enter documents, rCARD will automatically recognize each abbreviation. For abbreviations with multiple possible senses, rCARD will show a ranked list of possible meanings with the best predicted sense at the top. The prototype application embodies three word sense disambiguation (WSD) methods to predict the correct senses of abbreviations. We then conducted three experments to evaluate rCARD, including 1) a performance evaluation of different WSD methods; 2) a time evaluation of real-time WSD methods; and 3) a user study of typing clinical sentences with abbreviations using rCARD. Using 4,721 sentences containing 25 commonly observed, highly ambiguous clinical abbreviations, our evaluation showed that the best profile-based method implemented in rCARD achieved a reasonable WSD accuracy of 88.8% (comparable to SVM - 89.5%) and the cost of time for the different WSD methods are also acceptable (ranging from 0.630 to 1.649 milliseconds within the same network). The preliminary user study also showed that the extra time costs by rCARD were about 5% of total document entry time and users did not feel a significant delay when using rCARD for clinical document entry. The study indicates that it is feasible to integrate a real-time, NLP-enabled abbreviation recognition and disambiguation module with clinical documentation systems.
ERIC Educational Resources Information Center
Paladino, Emily B.; Klentzin, Jacqueline C.; Mills, Chloe P.
2017-01-01
Based on in-person, task-based usability testing and interviews, the authors' library Web site was recently overhauled in order to improve user experience. This led to the authors' interest in additional usability testing methods and test environments that would most closely fit their library's goals and situation. The appeal of card sorting…
ERIC Educational Resources Information Center
Buss, Aaron T.; Spencer, John P.
2012-01-01
The Dimensional Change Card Sort (DCCS) task requires children to switch from sorting cards based on shape or color to sorting based on the other dimension. Typically, 3-year-olds perseverate, whereas 4-year-olds flexibly sort by different dimensions. Zelazo and colleagues (1996, Cognitive Development, 11, 37-63) asked children questions about the…
Attacking of SmartCard-Based Banking Applications with JavaScript-Based Rootkits
NASA Astrophysics Data System (ADS)
Bußmeyer, Daniel; Gröbert, Felix; Schwenk, Jörg; Wegener, Christoph
Due to recent attacks on online banking systems and consequent soaring losses through fraud, different methods have been developed to ensure a secure connection between a bank and its customers. One method is the inclusion of smart card readers into these schemes, which come along with different benefits, e.g., convenience and costs, and endangerments, especially on the security side.
ERIC Educational Resources Information Center
Bass, Gwen; Lee, Ji Hee; Wells, Craig; Carey, John C.; Lee, Sangmin
2015-01-01
The scale development and exploratory and confirmatory factor analyses of the Protective Factor Index (PFI) is described. The PFI is a 13-item component of elementary students' report cards that replaces typical items associated with student behavior. The PFI is based on the Construct-Based Approach (CBA) to school counseling, which proposes that…
Standardized Solution for Management Controller for MTCA.4
NASA Astrophysics Data System (ADS)
Makowski, D.; Fenner, M.; Ludwig, F.; Mavrič, U.; Mielczarek, A.; Napieralski, A.; Perek, P.; Schlarb, H.
2015-06-01
The Micro Telecommunications Computing Architecture (MTCA) standard is a modern platform that is gaining popularity in the area of High Energy Physics (HEP) experiments. The standard provides extensive management, monitoring and diagnostics functionalities. The hardware control and monitoring is based on the Intelligent Platform Management Interface (IPMI), that was initially developed for supervision of complex computers operation. The original IPMI specification was extended to support functions required by the MTCA specification. The Module Management Controller (MMC) is required on each Advanced Mezzanine Card (AMC) installed in MTCA chassis. The Rear Transition Modules (RTMs) have to be equipped with RTM Management Controllers (RMCs) which is required by the MTCA.4 subsidiary specification. The commercially available implementations of MMC and RMC are expensive and do not provide the complete functionality that is required by specific HEP applications. Therefore, many research centers and commercial companies work on their own implementation of AMC and RTM controllers. The available implementations suffer because of lack of common approach and interoperability problems. Since both Lodz University of Technology (TUL) and Deutsches Elektronen-Synchrotron (DESY) have long-term experience in developing ATCA and MTCA hardware, the authors decided to develop a unified solution of management controller fully compliant with AMC and MTCA.4 standards. The MMC v1.00 solution is dedicated for management of AMC and RTM modules. The MMC v1.00 is based on Atmel ATxmega MCUs and can be fully customized by the user or used as a drop-in-module without any modifications. The paper discusses the functionality of the MMC v1.00 solution. The implementation was verified with developed evaluation kits for AMC and RTM cards.
2011-12-29
ISS030-E-017776 (29 Dec. 2011) --- Working in chorus with the International Space Station team in Houston?s Mission Control Center, this astronaut and his Expedition 30 crewmates on the station install a set of Enhanced Processor and Integrated Communications (EPIC) computer cards in one of seven primary computers onboard. The upgrade will allow more experiments to operate simultaneously, and prepare for the arrival of commercial cargo ships later this year.
ERIC Educational Resources Information Center
Fisher, Anna V.
2011-01-01
Two experiments tested a hypothesis that reducing demands on executive control in a Dimensional Change Card Sort task will lead to improved performance in 3-year-olds. In Experiment 1, the shape dimension was represented by two dissimilar values ("stars" and "flowers"), and the color dimension was represented by two similar values ("red" and…
Inventory of Archaeological and Historical Resources Lava Flow Control Study, Hilo, Hawaii,
1979-05-01
amale- p 11111 S.PIaN. Sitea card; hial. 1971 :2 aa. INVENTRh Y OF AIIAj4AOLGICAL AND HISIORICAL ESItIMCES Sit umber Site Dedption e Period Coed...liaison. 1932:294 SO-a-Al-ST Kalled , paved 4 PPI.Site Card; NHudson, 1932:29S.2W6 terraced platorm bo-Li-AI. 55$ Legendary crevite, Esrsaa% 1903:Is
Looking at Debit and Credit Card Fraud
ERIC Educational Resources Information Center
Porkess, Roger; Mason, Stephen
2012-01-01
This article, written jointly by a mathematician and a barrister, looks at some of the statistical issues raised by court cases based on fraud involving chip and PIN cards. It provides examples and insights that statistics teachers should find helpful. (Contains 4 tables and 1 figure.)
Biometrics based authentication scheme for session initiation protocol.
Xie, Qi; Tang, Zhixiong
2016-01-01
Many two-factor challenge-response based session initiation protocol (SIP) has been proposed, but most of them are vulnerable to smart card stolen attacks and password guessing attacks. In this paper, we propose a novel three-factor SIP authentication scheme using biometrics, password and smart card, and utilize the pi calculus-based formal verification tool ProVerif to prove that the proposed protocol achieves security and authentication. Furthermore, our protocol is highly efficient when compared to other related protocols.
Phongsavan, Keokedthong; Gustavsson, Inger; Marions, Lena; Phengsavanh, Alongkone; Wahlström, Rolf; Gyllensten, Ulf
2012-10-01
Persistent infection with high-risk (HR) human papillomavirus (HPV) is a well-recognized cause of cervical cancer, but little is known about the situation in Laos. The aims of the study were to determine the prevalence of HR-HPV among Lao women and to evaluate the use of a filter paper card (FTA Elute Micro Card) for collection of cervical cells in the humid tropical climate. This is a cross-sectional study including 1922 women from 3 provinces in Laos. During a gynecological examination, cervical cells were collected and applied to the FTA card followed by HPV typing using a real-time polymerase chain reaction (PCR)-based assay. Overall, 213 of the 1922 women were positive for HR-HPV (11%). The most common type was the group HPV33/52/58 (3%), followed by the single type 16 (2%) and the group 18/45 (1%), respectively. Only 11 cards (0.6%) did not contain a sufficient amount of genomic DNA for polymerase chain reaction-based analysis. The prevalence of HR-HPV infections in Laos is similar to other Asian countries, and 40% of the women with an HR-HPV infection will be target of the present HPV vaccines. The FTA card is suitable for collection of cervical cells for HR-HPV typing in tropical conditions. This information is important for planning and establishing primary and secondary prevention of cervical cancer in Laos.
Mukamel, Dana B; Spector, William D; Zinn, Jacqueline; Weimer, David L; Ahn, Richard
2010-10-01
Nursing Home Compare first published clinical quality measures at the end of 2002. It is a quality report card that for the first time offers consumers easily accessible information about the clinical quality of nursing homes. It led to changes in consumers' demand, increasing the relative importance of clinical versus hotel aspects of quality in their search and choice of a nursing home. To examine the hypothesis that nursing homes responding to these changes in demand shifted the balance of resources from hotel to clinical activities. The study included 10,022 free-standing nursing homes nationwide during 2001 to 2006. RESEARCH DESIGN AND DATA: A retrospective multivariate statistical analysis of trends in the ratio of clinical to hotel expenditures, using Medicare cost reports, Minimum Data Set and Online Survey, Certification and Reporting data, controlling for changes in residents' acuity and facility fixed effects. Inference is based on robust standard errors. The ratio of clinical to hotel expenditures averaged 1.78. It increased significantly (P < 0.001) by 5% following the publication of the report card. The increase was larger and more significant among nursing homes with worse reported quality, lower occupancy, those located in more competitive markets, for-profit ownership and owned by a chain. The increase in the ratio of clinical to hotel expenditures following publication of the report card suggests that nursing homes responded as expected to the changes in the elasticity of demand with respect to clinical quality brought about by the public reporting of clinical quality measures. The response was stronger among nursing homes facing stronger incentives.
Low-Speed Fingerprint Image Capture System User`s Guide, June 1, 1993
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whitus, B.R.; Goddard, J.S.; Jatko, W.B.
1993-06-01
The Low-Speed Fingerprint Image Capture System (LS-FICS) uses a Sun workstation controlling a Lenzar ElectroOptics Opacity 1000 imaging system to digitize fingerprint card images to support the Federal Bureau of Investigation`s (FBI`s) Automated Fingerprint Identification System (AFIS) program. The system also supports the operations performed by the Oak Ridge National Laboratory- (ORNL-) developed Image Transmission Network (ITN) prototype card scanning system. The input to the system is a single FBI fingerprint card of the agreed-upon standard format and a user-specified identification number. The output is a file formatted to be compatible with the National Institute of Standards and Technology (NIST)more » draft standard for fingerprint data exchange dated June 10, 1992. These NIST compatible files contain the required print and text images. The LS-FICS is designed to provide the FBI with the capability of scanning fingerprint cards into a digital format. The FBI will replicate the system to generate a data base of test images. The Host Workstation contains the image data paths and the compression algorithm. A local area network interface, disk storage, and tape drive are used for the image storage and retrieval, and the Lenzar Opacity 1000 scanner is used to acquire the image. The scanner is capable of resolving 500 pixels/in. in both x and y directions. The print images are maintained in full 8-bit gray scale and compressed with an FBI-approved wavelet-based compression algorithm. The text fields are downsampled to 250 pixels/in. and 2-bit gray scale. The text images are then compressed using a lossless Huffman coding scheme. The text fields retrieved from the output files are easily interpreted when displayed on the screen. Detailed procedures are provided for system calibration and operation. Software tools are provided to verify proper system operation.« less
NASA Astrophysics Data System (ADS)
Barros Marin, M.; Boccardi, A.; Donat Godichal, C.; Gonzalez, J. L.; Lefevre, T.; Levens, T.; Szuk, B.
2016-02-01
The Giga Bit Transceiver based Expandable Front-End (GEFE) is a multi-purpose FPGA-based radiation tolerant card. It is foreseen to be the new standard FMC carrier for digital front-end applications in the CERN BE-BI group. Its intended use ranges from fast data acquisition systems to slow control installed close to the beamlines, in a radioactive environment exposed to total ionizing doses of up to 750 Gy. This paper introduces the architecture of the GEFE, its features as well as examples of its application in different setups.
Spirituality as a predictive factor for signing an organ donor card.
Bortz, Anat Peles; Ashkenazi, Tamar; Melnikov, Semyon
2015-01-01
To examine differences in spirituality, purpose in life, and attitudes toward organ donation between people who signed and those who did not sign an organ donor card. A descriptive cross-sectional survey conducted in Israel with a sample of 312 respondents from the general population, of whom 220 (70.5%) signed an organ donor card. Data were collected during April-June 2013. Participants completed a paper questionnaire and a Web-based questionnaire consisting of four sections: spiritual health, purpose in life, attitudes toward organ donation, and social-demographic questions. Descriptive statistics, t test, chi-square test, and a logistic regression analysis were performed. Differences in mean scores between respondents who signed an organ donor card and those who did not were indicated in transcendental spirituality (p < .01), purpose in life (p < .05), and attitudes toward organ donation (p < .01). No statistically significant difference was found between the groups in the overall spirituality mean score. The spiritual transcendental dimension, individual's purpose in life, and attitudes toward organ donation explained 34.3% of the variance of signing an organ donor card. Signing an organ donor card was found to be correlated with high purpose in life, positive attitudes toward organ donation, and low level of transcendental spirituality. Nurses should assess the patient's spiritual needs in order to construct appropriate programs for promoting signing an organ donor card. Nurses who signed an organ donor card should be encouraged to share this information with their patients. © 2014 Sigma Theta Tau International.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This report contains papers on the following topics: NREN Security Issues: Policies and Technologies; Layer Wars: Protect the Internet with Network Layer Security; Electronic Commission Management; Workflow 2000 - Electronic Document Authorization in Practice; Security Issues of a UNIX PEM Implementation; Implementing Privacy Enhanced Mail on VMS; Distributed Public Key Certificate Management; Protecting the Integrity of Privacy-enhanced Electronic Mail; Practical Authorization in Large Heterogeneous Distributed Systems; Security Issues in the Truffles File System; Issues surrounding the use of Cryptographic Algorithms and Smart Card Applications; Smart Card Augmentation of Kerberos; and An Overview of the Advanced Smart Card Access Control System.more » Selected papers were processed separately for inclusion in the Energy Science and Technology Database.« less
High density processing electronics for superconducting tunnel junction x-ray detector arrays
NASA Astrophysics Data System (ADS)
Warburton, W. K.; Harris, J. T.; Friedrich, S.
2015-06-01
Superconducting tunnel junctions (STJs) are excellent soft x-ray (100-2000 eV) detectors, particularly for synchrotron applications, because of their ability to obtain energy resolutions below 10 eV at count rates approaching 10 kcps. In order to achieve useful solid detection angles with these very small detectors, they are typically deployed in large arrays - currently with 100+ elements, but with 1000 elements being contemplated. In this paper we review a 5-year effort to develop compact, computer controlled low-noise processing electronics for STJ detector arrays, focusing on the major issues encountered and our solutions to them. Of particular interest are our preamplifier design, which can set the STJ operating points under computer control and achieve 2.7 eV energy resolution; our low noise power supply, which produces only 2 nV/√Hz noise at the preamplifier's critical cascode node; our digital processing card that digitizes and digitally processes 32 channels; and an STJ I-V curve scanning algorithm that computes noise as a function of offset voltage, allowing an optimum operating point to be easily selected. With 32 preamplifiers laid out on a custom 3U EuroCard, and the 32 channel digital card in a 3U PXI card format, electronics for a 128 channel array occupy only two small chassis, each the size of a National Instruments 5-slot PXI crate, and allow full array control with simple extensions of existing beam line data collection packages.
Privacy-Preserving Authentication of Users with Smart Cards Using One-Time Credentials
NASA Astrophysics Data System (ADS)
Park, Jun-Cheol
User privacy preservation is critical to prevent many sophisticated attacks that are based on the user's server access patterns and ID-related information. We propose a password-based user authentication scheme that provides strong privacy protection using one-time credentials. It eliminates the possibility of tracing a user's authentication history and hides the user's ID and password even from servers. In addition, it is resistant against user impersonation even if both a server's verification database and a user's smart card storage are disclosed. We also provide a revocation scheme for a user to promptly invalidate the user's credentials on a server when the user's smart card is compromised. The schemes use lightweight operations only such as computing hashes and bitwise XORs.
2018-01-01
The Session Initiation Protocol (SIP) is an extensive and esteemed communication protocol employed to regulate signaling as well as for controlling multimedia communication sessions. Recently, Kumari et al. proposed an improved smart card based authentication scheme for SIP based on Farash’s scheme. Farash claimed that his protocol is resistant against various known attacks. But, we observe some accountable flaws in Farash’s protocol. We point out that Farash’s protocol is prone to key-compromise impersonation attack and is unable to provide pre-verification in the smart card, efficient password change and perfect forward secrecy. To overcome these limitations, in this paper we present an enhanced authentication mechanism based on Kumari et al.’s scheme. We prove that the proposed protocol not only overcomes the issues in Farash’s scheme, but it can also resist against all known attacks. We also provide the security analysis of the proposed scheme with the help of widespread AVISPA (Automated Validation of Internet Security Protocols and Applications) software. At last, comparing with the earlier proposals in terms of security and efficiency, we conclude that the proposed protocol is efficient and more secure. PMID:29547619
Realization of time keeping alarming system based on CTI technique
NASA Astrophysics Data System (ADS)
Cai, Cheng-Lin; Dong, Shao-Wu
2003-12-01
An application of CTI (Computer Telephone Integration) technique to fault alarming in time keeping system is presented in this paper. Two key parts of this alarming system, telephone phonic card and TTS (Text To Speech) are briefly introduced. A series of events and methods for programming interface based on ActiveX control (phonic.OCX) is discussed, and an alarming program module is developed. The alarming program module can be used in reporting accidents for time keeping system, and can also be applied to power supply system and environmental monitoring system.
CARDS: A blueprint and environment for domain-specific software reuse
NASA Technical Reports Server (NTRS)
Wallnau, Kurt C.; Solderitsch, Anne Costa; Smotherman, Catherine
1992-01-01
CARDS (Central Archive for Reusable Defense Software) exploits advances in domain analysis and domain modeling to identify, specify, develop, archive, retrieve, understand, and reuse domain-specific software components. An important element of CARDS is to provide visibility into the domain model artifacts produced by, and services provided by, commercial computer-aided software engineering (CASE) technology. The use of commercial CASE technology is important to provide rich, robust support for the varied roles involved in a reuse process. We refer to this kind of use of knowledge representation systems as supporting 'knowledge-based integration.'
Moon, Jongho; Lee, Donghoon; Lee, Youngsook; Won, Dongho
2017-04-25
User authentication in wireless sensor networks is more difficult than in traditional networks owing to sensor network characteristics such as unreliable communication, limited resources, and unattended operation. For these reasons, various authentication schemes have been proposed to provide secure and efficient communication. In 2016, Park et al. proposed a secure biometric-based authentication scheme with smart card revocation/reissue for wireless sensor networks. However, we found that their scheme was still insecure against impersonation attack, and had a problem in the smart card revocation/reissue phase. In this paper, we show how an adversary can impersonate a legitimate user or sensor node, illegal smart card revocation/reissue and prove that Park et al.'s scheme fails to provide revocation/reissue. In addition, we propose an enhanced scheme that provides efficiency, as well as anonymity and security. Finally, we provide security and performance analysis between previous schemes and the proposed scheme, and provide formal analysis based on the random oracle model. The results prove that the proposed scheme can solve the weaknesses of impersonation attack and other security flaws in the security analysis section. Furthermore, performance analysis shows that the computational cost is lower than the previous scheme.
Comparison of DNA preservation methods for environmental bacterial community samples
Gray, Michael A.; Pratte, Zoe A.; Kellogg, Christina A.
2013-01-01
Field collections of environmental samples, for example corals, for molecular microbial analyses present distinct challenges. The lack of laboratory facilities in remote locations is common, and preservation of microbial community DNA for later study is critical. A particular challenge is keeping samples frozen in transit. Five nucleic acid preservation methods that do not require cold storage were compared for effectiveness over time and ease of use. Mixed microbial communities of known composition were created and preserved by DNAgard™, RNAlater®, DMSO–EDTA–salt (DESS), FTA® cards, and FTA Elute® cards. Automated ribosomal intergenic spacer analysis and clone libraries were used to detect specific changes in the faux communities over weeks and months of storage. A previously known bias in FTA® cards that results in lower recovery of pure cultures of Gram-positive bacteria was also detected in mixed community samples. There appears to be a uniform bias across all five preservation methods against microorganisms with high G + C DNA. Overall, the liquid-based preservatives (DNAgard™, RNAlater®, and DESS) outperformed the card-based methods. No single liquid method clearly outperformed the others, leaving method choice to be based on experimental design, field facilities, shipping constraints, and allowable cost.
Moon, Jongho; Lee, Donghoon; Lee, Youngsook; Won, Dongho
2017-01-01
User authentication in wireless sensor networks is more difficult than in traditional networks owing to sensor network characteristics such as unreliable communication, limited resources, and unattended operation. For these reasons, various authentication schemes have been proposed to provide secure and efficient communication. In 2016, Park et al. proposed a secure biometric-based authentication scheme with smart card revocation/reissue for wireless sensor networks. However, we found that their scheme was still insecure against impersonation attack, and had a problem in the smart card revocation/reissue phase. In this paper, we show how an adversary can impersonate a legitimate user or sensor node, illegal smart card revocation/reissue and prove that Park et al.’s scheme fails to provide revocation/reissue. In addition, we propose an enhanced scheme that provides efficiency, as well as anonymity and security. Finally, we provide security and performance analysis between previous schemes and the proposed scheme, and provide formal analysis based on the random oracle model. The results prove that the proposed scheme can solve the weaknesses of impersonation attack and other security flaws in the security analysis section. Furthermore, performance analysis shows that the computational cost is lower than the previous scheme. PMID:28441331
Computerized Integrated Inventory Control for an Air Force Base-Level Supply System.
1980-06-01
3465 4710-4730 9110-9180 3515-3540 4810-4820 9320-9360 3620-3694 4910-4940 9505 -9540 3720-2750 5110-5180 9620-9650 3805-3030 5210-5280 3910-3995 4010...Buffers Disc Files Input 1.2 K Output 1.2 K 2.4 K Printer 2 (double) x 150 .0003 K Tape Input 1.2 K Output 1.2 K 2.4 K Card Reader 2 (double) x 100 . 0002
NASA Technical Reports Server (NTRS)
Collins, Earl R., Jr.
1990-01-01
Authorized users respond to changing challenges with changing passwords. Scheme for controlling access to computers defeats eavesdroppers and "hackers". Based on password system of challenge and password or sign, challenge, and countersign correlated with random alphanumeric codes in matrices of two or more dimensions. Codes stored on floppy disk or plug-in card and changed frequently. For even higher security, matrices of four or more dimensions used, just as cubes compounded into hypercubes in concurrent processing.
NASA Astrophysics Data System (ADS)
Hejtmánek, M.; Neue, G.; Voleš, P.
2015-06-01
This article is devoted to the software design and development of a high-speed readout application used for interfacing particle detectors via the CoaXPress communication standard. The CoaXPress provides an asymmetric high-speed serial connection over a single coaxial cable. It uses a widely available 75 Ω BNC standard and can operate in various modes with a data throughput ranging from 1.25 Gbps up to 25 Gbps. Moreover, it supports a low speed uplink with a fixed bit rate of 20.833 Mbps, which can be used to control and upload configuration data to the particle detector. The CoaXPress interface is an upcoming standard in medical imaging, therefore its usage promises long-term compatibility and versatility. This work presents an example of how to develop DAQ system for a pixel detector. For this purpose, a flexible DAQ card was developed using the XILINX Spartan 6 FPGA. The DAQ card is connected to the framegrabber FireBird CXP6 Quad, which is plugged in the PCI Express bus of the standard PC. The data transmission was performed between the FPGA and framegrabber card via the standard coaxial cable in communication mode with a bit rate of 3.125 Gbps. Using the Medipix2 Quad pixel detector, the framerate of 100 fps was achieved. The front-end application makes use of the FireBird framegrabber software development kit and is suitable for data acquisition as well as control of the detector through the registers implemented in the FPGA.
Zinzow-Kramer, W M; Long, A B; Youngblood, B A; Rosenthal, K M; Butler, R; Mohammed, A-U-R; Skountzou, I; Ahmed, R; Evavold, B D; Boss, J M
2012-06-01
Three distinct promoters control the master regulator of major histocompatibility complex (MHC) class II expression, class II transactivator (CIITA), in a cell type-specific manner. Promoter I (pI) CIITA, expressed primarily by dendritic cells (DCs) and macrophages, expresses a unique isoform that contains a caspase-recruitment domain (CARD). The activity and function of this isoform are not understood, but are believed to enhance the function of CIITA in antigen-presenting cells. To determine whether isoform I of CIITA has specific functions, CIITA mutant mice were created in which isoform I was replaced with isoform III sequences. Mice in which pI and the CARD-encoding exon were deleted were also created. No defect in the formation of CD4 T cells, the ability to respond to a model antigen or bacterial or viral challenge was observed in mice lacking CIITA isoform I. Although CIITA and MHC-II expression was decreased in splenic DCs, pI knockout animals expressed CIITA from downstream promoters, suggesting that control of pI activity is mediated by unknown distal elements that could act at pIII, the B-cell promoter. Thus, no critical function is linked to the CARD domain of CIITA isoform I with respect to basic immune system development, function and challenge.
User authentication based on the NFC host-card-emulation technology
NASA Astrophysics Data System (ADS)
Kološ, Jan; Kotyrba, Martin
2017-11-01
This paper deals with implementation of algorithms for data exchange between mobile devices supporting NFC HCE (Host-Card-Emulation) and a contactless NFC reader communicating in a read/write mode. This solution provides multiplatform architecture for data exchange between devices with a focus on safe and simple user authentication.
Hypertext Image Retrieval: The Evolution of an Application.
ERIC Educational Resources Information Center
Roberts, G. Louis; Kenney, Carol E.
1991-01-01
Describes the development and implementation of a full-text image retrieval system at the Boeing Commercial Airplane Group. The conversion of card formats to a microcomputer-based system using HyperCard is described; the online system architecture is explained; and future plans are discussed, including conversion to digital images. (LRW)
Specifications and implementation of the RT MHD control system for the EC launcher of FTU
NASA Astrophysics Data System (ADS)
Galperti, C.; Alessi, E.; Boncagni, L.; Bruschi, A.; Granucci, G.; Grosso, A.; Iannone, F.; Marchetto, C.; Nowak, S.; Panella, M.; Sozzi, C.; Tilia, B.
2012-09-01
To perform real time plasma control experiments using EC heating waves by using the new fast launcher installed on FTU a dedicated data acquisition and elaboration system has been designed recently. A prototypical version of the acquisition/control system has been recently developed and will be tested on FTU machine in its next experimental campaign. The open-source framework MARTe (Multi-threaded Application Real-Time executor) on Linux/RTAI real-time operating system has been chosen as software platform to realize the control system. Standard open-architecture industrial PCs, based either on VME bus and CompactPCI bus equipped with standard input/output cards are the chosen hardware platform.
DNA-magnetic bead detection using disposable cards and the anisotropic magnetoresistive sensor
NASA Astrophysics Data System (ADS)
Hien, L. T.; Quynh, L. K.; Huyen, V. T.; Tu, B. D.; Hien, N. T.; Phuong, D. M.; Nhung, P. H.; Giang, D. T. H.; Duc, N. H.
2016-12-01
A disposable card incorporating specific DNA probes targeting the 16 S rRNA gene of Streptococcus suis was developed for magnetically labeled target DNA detection. A single-stranded target DNA was hybridized with the DNA probe on the SPA/APTES/PDMS/Si as-prepared card, which was subsequently magnetically labeled with superparamagnetic beads for detection using an anisotropic magnetoresistive (AMR) sensor. An almost linear response between the output signal of the AMR sensor and amount of single-stranded target DNA varied from 4.5 to 18 pmol was identified. From the sensor output signal response towards the mass of magnetic beads which were directly immobilized on the disposable card surface, the limit of detection was estimated about 312 ng ferrites, which corresponds to 3.8 μemu. In comparison with DNA detection by conventional biosensor based on magnetic bead labeling, disposable cards are featured with higher efficiency and performances, ease of use and less running cost with respects to consumables for biosensor in biomedical analysis systems operating with immobilized bioreceptor.
Hubin, Elizabeth A; Fay, Allison; Xu, Catherine; Bean, James M; Saecker, Ruth M; Glickman, Michael S; Darst, Seth A; Campbell, Elizabeth A
2017-01-01
RbpA and CarD are essential transcription regulators in mycobacteria. Mechanistic analyses of promoter open complex (RPo) formation establish that RbpA and CarD cooperatively stimulate formation of an intermediate (RP2) leading to RPo; formation of RP2 is likely a bottleneck step at the majority of mycobacterial promoters. Once RPo forms, CarD also disfavors its isomerization back to RP2. We determined a 2.76 Å-resolution crystal structure of a mycobacterial transcription initiation complex (TIC) with RbpA as well as a CarD/RbpA/TIC model. Both CarD and RbpA bind near the upstream edge of the −10 element where they likely facilitate DNA bending and impede transcription bubble collapse. In vivo studies demonstrate the essential role of RbpA, show the effects of RbpA truncations on transcription and cell physiology, and indicate additional functions for RbpA not evident in vitro. This work provides a framework to understand the control of mycobacterial transcription by RbpA and CarD. DOI: http://dx.doi.org/10.7554/eLife.22520.001 PMID:28067618
Njenga, S M; Wamae, C N
2001-10-01
An immunochromatographic card test (ICT) that uses fingerprick whole blood instead of serum for diagnosis of bancroftian filariasis has recently been developed. The card test was validated in the field in Kenya by comparing its sensitivity to the combined sensitivity of Knott's concentration and counting chamber methods. A total of 102 (14.6%) and 117 (16.7%) persons was found to be microfilaremic by Knott's concentration and counting chamber methods, respectively. The geometric mean intensities (GMI) were 74.6 microfilariae (mf)/ml and 256.5 mf/ml by Knott's concentration and counting chamber methods, respectively. All infected individuals detected by both Knott's concentration and counting chamber methods were also antigen positive by the ICT filariasis card test (100% sensitivity). Further, of 97 parasitologically amicrofilaremic persons, 24 (24.7%) were antigen positive by the ICT. The overall prevalence of antigenemia was 37.3%. Of 100 nonendemic area control persons, none was found to be filarial antigen positive (100% specificity). The results show that the new version of the ICT filariasis card test is a simple, sensitive, specific, and rapid test that is convenient in field settings.
Visual stimuli in intervention approaches for pre-schoolers diagnosed with phonological delay.
Pedro, Cassandra Ferreira; Lousada, Marisa; Hall, Andreia; Jesus, Luis M T
2018-04-01
The aim of this study was to develop and content validate specific speech and language intervention picture cards: The Letter-Sound (L&S) cards. The present study was also focused on assessing the influence of these cards on letter-sound correspondences and speech sound production. An expert panel of six speech and language therapists analysed and discussed the L&S cards based on several criteria previously established. A Speech and Language Therapist carried out a 6-week therapeutic intervention with a group of seven Portuguese phonologically delayed pre-schoolers aged 5;3 to 6;5. The modified Bland-Altman method revealed good agreement among evaluators, that is the majority of the values was between the agreement limits. Additional outcome measures were collected before and after the therapeutic intervention process. Results indicate that the L&S cards facilitate the acquisition of letter-sound correspondences. Regarding speech sound production, some improvements were also observed at word level. The L&S cards are therefore likely to give phonetic cues, which are crucial for the correct production of therapeutic targets. These visual cues seemed to have helped children with phonological delay develop the above-mentioned skills.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bharoto,; Suparno, Nadi; Putra, Edy Giri Rachman
In 2005, the main computer for data acquisition and control system of Small-angle Neutron Scattering (SANS) BATAN Spectrometer (SMARTer) was replaced since it halted to operate the spectrometer. According to this replacement, the new software for data acquisition and control system has been developed in-house. Visual Basic programming language is used in developing the software. In the last two years, many developments have been made both in the hardware and also the software to conduct the experiment is more effective and efficient. Lately, the previous motor controller card (ISA Card) was replaced with the programmable motor controller card (PCI Card)more » for driving one motor of position sensitive detector (PSD), eight motors of four collimators, and six motors of six pinhole discs. This new control system software makes all motors can be moved simultaneously, then it reduces significantly the consuming time of setting up the instrument before running the experiment. Along with that development, the new data acquisition software under MS Windows operating system is also developed to drive a beam stopper in X-Y directions as well as to read the equipment status such as position of the collimators and PSD, to acquire neutron counts on monitor and PSD detectors, and also to manage 12 samples position automatically. A timer object which is set in one second to read the equipment status via serial port of the computer (RS232C), and general purpose interface board (GPIB) for reading the total counts of each pixel of the PSD from histogram memory was used in this new software. The experiment result displayed in real time on the main window, and the data is saved in the special format for further data reduction and analysis. The new software has been implemented and performed for experiment using a preset count or preset time mode for absolute scattering intensity method.« less
NASA Astrophysics Data System (ADS)
Bharoto, Suparno, Nadi; Putra, Edy Giri Rachman
2015-04-01
In 2005, the main computer for data acquisition and control system of Small-angle Neutron Scattering (SANS) BATAN Spectrometer (SMARTer) was replaced since it halted to operate the spectrometer. According to this replacement, the new software for data acquisition and control system has been developed in-house. Visual Basic programming language is used in developing the software. In the last two years, many developments have been made both in the hardware and also the software to conduct the experiment is more effective and efficient. Lately, the previous motor controller card (ISA Card) was replaced with the programmable motor controller card (PCI Card) for driving one motor of position sensitive detector (PSD), eight motors of four collimators, and six motors of six pinhole discs. This new control system software makes all motors can be moved simultaneously, then it reduces significantly the consuming time of setting up the instrument before running the experiment. Along with that development, the new data acquisition software under MS Windows operating system is also developed to drive a beam stopper in X-Y directions as well as to read the equipment status such as position of the collimators and PSD, to acquire neutron counts on monitor and PSD detectors, and also to manage 12 samples position automatically. A timer object which is set in one second to read the equipment status via serial port of the computer (RS232C), and general purpose interface board (GPIB) for reading the total counts of each pixel of the PSD from histogram memory was used in this new software. The experiment result displayed in real time on the main window, and the data is saved in the special format for further data reduction and analysis. The new software has been implemented and performed for experiment using a preset count or preset time mode for absolute scattering intensity method.
Sigsgaard, Lene; Herz, Annette; Korsgaard, Maren; Wührer, Bernd
2017-01-01
Cydia pomonella is a major pest in apples in Denmark. Trichogramma spp. are known biocontrol agents of C. pomonella eggs and two naturally occurring species in Denmark, which are also both commercially available, were chosen for mass-release trials. Trichogramma evanescens, T. cacoeciae or a mix of the two species were evaluated for mass-release to control C. pomonella in two commercial organic apple orchards, one in 2012 and one in 2013, using a complete randomized block design. Pheromone disruption was used in both orchards, making the study one of the first to evaluate Trichogramma release under a mating disruption regime. Trichogramma activity was assessed using bait cards with Sitotroga cerealella eggs. The percent C. pomonella damaged fruit was recorded and the fruit yield was estimated. In 2012 cool and wet weather conditions resulted in low Trichogramma activity (<16% bait cards parasitized) and only T. evanescens was recovered from bait cards. The conditions in 2013 were warmer but T. evanescens was still >10 times more frequently found in bait cards than T. cacoeciae. There was a significant effect of the treatment and year (p = 0.009) and of the sampling period (p = 0.0008) on Trichogramma activity (proportion bait cards parasitized), with no significant difference between treatments in 2012. In 2013 the highest activity was found in T. evanescens and mixed treatments, in July reaching 69% and 47% bait cards parasitized, respectively. Fruit damage was highest in the control plots (7.1%) compared with Trichogramma treatments (T. evanescens 2.8%, T. cacoeciae 3.8%, mixed 3.3%) (p = 0.028). Yield did not differ significantly between treatments. In conclusion, Trichogramma mass release is a promising biocontrol method for use in the Danish climate, but further studies are needed regarding the performance of the two Trichogramma species (and potential other Trichogramma species) towards C. pomonella eggs in the field to identify the best biocontrol candidate. PMID:28375171
Sigsgaard, Lene; Herz, Annette; Korsgaard, Maren; Wührer, Bernd
2017-04-04
Cydia pomonella is a major pest in apples in Denmark. Trichogramma spp. are known biocontrol agents of C. pomonella eggs and two naturally occurring species in Denmark, which are also both commercially available, were chosen for mass-release trials. Trichogramma evanescens , T. cacoeciae or a mix of the two species were evaluated for mass-release to control C. pomonella in two commercial organic apple orchards, one in 2012 and one in 2013, using a complete randomized block design. Pheromone disruption was used in both orchards, making the study one of the first to evaluate Trichogramma release under a mating disruption regime. Trichogramma activity was assessed using bait cards with Sitotroga cerealella eggs. The percent C. pomonella damaged fruit was recorded and the fruit yield was estimated. In 2012 cool and wet weather conditions resulted in low Trichogramma activity (<16% bait cards parasitized) and only T. evanescens was recovered from bait cards. The conditions in 2013 were warmer but T. evanescens was still >10 times more frequently found in bait cards than T. cacoeciae . There was a significant effect of the treatment and year ( p = 0.009) and of the sampling period ( p = 0.0008) on Trichogramma activity (proportion bait cards parasitized), with no significant difference between treatments in 2012. In 2013 the highest activity was found in T. evanescens and mixed treatments, in July reaching 69% and 47% bait cards parasitized, respectively. Fruit damage was highest in the control plots (7.1%) compared with Trichogramma treatments ( T. evanescens 2.8%, T. cacoeciae 3.8%, mixed 3.3%) ( p = 0.028). Yield did not differ significantly between treatments. In conclusion, Trichogramma mass release is a promising biocontrol method for use in the Danish climate, but further studies are needed regarding the performance of the two Trichogramma species (and potential other Trichogramma species) towards C. pomonella eggs in the field to identify the best biocontrol candidate.
Vilhjálmsson, Rúnar; Sigurðardóttir, Guðrún V
2003-05-01
Research shows that out-of-pocket health care costs in Iceland and other Western European countries have increased in recent years, and unequal access to health services has been documented. In an attempt to contain out-of-pocket-costs and avoid service inequities, Icelandic health authorities have for a number of years issued health care discount cards. The purpose ot the study was to investigate the distribution of out-of-pocket physician costs and discount cards, and the extent to which the cards reach those who are entitled to them. The study is based on a national panel survey titled Health and Living Conditions in Iceland. A random sample of 18-75 year olds was drawn from the National Register. 1924 respondents participated in the first wave (69% response rate) and 1592 of them (83%) in the second wave. Cross-tabular analysis was used to investigate variations in out-of-pocket physician costs and discount card status across sociodemographic groups. 19.9% of the respondents had accumulated out-of-pocket costs that made them eligible for a discount card. Furthermore, there was considerable variation in the percentage of eligible individuals across population groups. The discount card was poorly distributed, as only 45.7% of eligible individuals had actually obtained a card. This lack of coverage was greatest among younger individuals, parents of young children, individuals in larger households, the full-time employed, and those who had more education and income. The purpose of the discount card is to even out and contain out-of-pocket physician care costs, and sustain equal access to physician services. The purpose is no more than partially reached, as only a minority of eligible individuals are actual cardholders. This can be largely explained by the fact that health authorities have done little to promote the card, and make it cumbersome for patients to obtain it.
Testing novel patient financial incentives to increase breast cancer screening.
Merrick, Elizabeth Levy; Hodgkin, Dominic; Horgan, Constance M; Lorenz, Laura S; Panas, Lee; Ritter, Grant A; Kasuba, Paul; Poskanzer, Debra; Nefussy, Renee Altman
2015-11-01
To examine the effects of 3 types of low-cost financial incentives for patients, including a novel "person-centered" approach on breast cancer screening (mammogram) rates. Randomized controlled trial with 4 arms: 3 types of financial incentives ($15 gift card, entry into lottery for $250 gift card, and a person-centered incentive with choice of $15 gift card or lottery) and a control group. Sample included privately insured Tufts Health Plan members in Massachusetts who were women aged 42 to 69 years with no mammogram claim in ≥ 2.6 years. A sample of 4700 eligible members were randomized to 4 study arms. The control group received a standard reminder letter and the incentive groups received a reminder letter plus an incentive offer for obtaining a mammogram within the next 4 months. Bivariate tests and multivariate logistic regression were used to assess the incentives' impact on mammogram receipt. Data were analyzed for 4427 members (after exclusions such as undeliverable mail). The percent of members receiving a mammogram during the study was 11.7% (gift card), 12.1% (lottery), 13.4% (person-centered/choice), and 11.9% (controls). Differences were not statistically significant in bivariate or multivariate full-sample analyses. In exploratory subgroup analyses of members with a mammogram during the most recent year prior to the study-defined gap, person-centered incentives were associated with a higher likelihood of mammogram receipt. None of the low-cost incentives tested had a statistically significant effect on mammogram rates in the full sample. Exploratory findings for members who were more recently screened suggest that they may be more responsive to person-centered incentives.
Isothermal thermogravimetric data acquisition analysis system
NASA Technical Reports Server (NTRS)
Cooper, Kenneth, Jr.
1991-01-01
The description of an Isothermal Thermogravimetric Analysis (TGA) Data Acquisition System is presented. The system consists of software and hardware to perform a wide variety of TGA experiments. The software is written in ANSI C using Borland's Turbo C++. The hardware consists of a 486/25 MHz machine with a Capital Equipment Corp. IEEE488 interface card. The interface is to a Hewlett Packard 3497A data acquisition system using two analog input cards and a digital actuator card. The system provides for 16 TGA rigs with weight and temperature measurements from each rig. Data collection is conducted in three phases. Acquisition is done at a rapid rate during initial startup, at a slower rate during extended data collection periods, and finally at a fast rate during shutdown. Parameters controlling the rate and duration of each phase are user programmable. Furnace control (raising and lowering) is also programmable. Provision is made for automatic restart in the event of power failure or other abnormal terminations. Initial trial runs were conducted to show system stability.
A versatile small form factor twisted-pair TFC FMC for MTCA AMCs
NASA Astrophysics Data System (ADS)
Meder, L.; Lebedev, J.; Becker, J.
2017-03-01
In continuous readout systems of particle physics experiments, the provision of a common clock and time reference and the distribution of critical low latency messages to the processing and fronted layers of the readout are crucial tasks. In the context of the Compressed Baryonic Matter (CBM) experiment, a versatile small form factor Timing and Fast-Control (TFC) interfacing FPGA Mezzanine Card (FMC) was developed, offering bidirectional twisted-pair (TP) links for the communication between TFC nodes. Also a versatile clocking including voltage controlled oscillators and a connection to the telecommunication clock lines of mTCA crates are available. Being designed for both TFC Master and Slaves, the card allows rapid system developments without additional Slave hardware circuits. Measurements show that it is possible to transmit over cable lengths of 25 m at a rate of 240 Mbit/s for all data channels simultaneously. A TFC Master-Slave system using two of these cards can be synchronized with a precision of ±10 ps to an user-defined phase setpoint.
NASA Technical Reports Server (NTRS)
Hammond, Dana P.
1991-01-01
The Technical Requirements Analysis and Control Systems (TRACS) software package is described. TRACS offers supplemental tools for the analysis, control, and interchange of project requirements. This package provides the fundamental capability to analyze and control requirements, serves a focal point for project requirements, and integrates a system that supports efficient and consistent operations. TRACS uses relational data base technology (ORACLE) in a stand alone or in a distributed environment that can be used to coordinate the activities required to support a project through its entire life cycle. TRACS uses a set of keyword and mouse driven screens (HyperCard) which imposes adherence through a controlled user interface. The user interface provides an interactive capability to interrogate the data base and to display or print project requirement information. TRACS has a limited report capability, but can be extended with PostScript conventions.
Card sorting to evaluate the robustness of the information architecture of a protocol website.
Wentzel, J; Müller, F; Beerlage-de Jong, N; van Gemert-Pijnen, J
2016-02-01
A website on Methicillin-Resistant Staphylococcus Aureus, MRSA-net, was developed for Health Care Workers (HCWs) and the general public, in German and in Dutch. The website's content was based on existing protocols and its structure was based on a card sort study. A Human Centered Design approach was applied to ensure a match between user and technology. In the current study we assess whether the website's structure still matches user needs, again via a card sort study. An open card sort study was conducted. Randomly drawn samples of 100 on-site search queries as they were entered on the MRSA-net website (during one year of use) were used as card input. In individual sessions, the cards were sorted by each participant (18 German and 10 Dutch HCWs, and 10 German and 10 Dutch members of the general public) into piles that were meaningful to them. Each participant provided a label for every pile of cards they created. Cluster analysis was performed on the resulting sorts, creating an overview of clusters of items placed together in one pile most frequently. In addition, pile labels were qualitatively analyzed to identify the participants' mental models. Cluster analysis confirmed existing categories and revealed new themes emerging from the search query samples, such as financial issues and consequences for the patient. Even though MRSA-net addresses these topics, they are not prominently covered in the menu structure. The label analysis shows that 7 of a total of 44 MRSA-net categories were not reproduced by the participants. Additional themes such as information on other pathogens and categories such as legal issues emerged. This study shows that the card sort performed to create MRSA-net resulted in overall long-lasting structure and categories. New categories were identified, indicating that additional information needs emerged. Therefore, evaluating website structure should be a recurrent activity. Card sorting with ecological data as input for the cards is useful to identify changes in needs and mental models. By combining qualitative and quantitative analysis we gained insight into additional information needed by the target group, including their view on the domain and related themes. The results show differences between the four user groups in their sorts, which can mostly be explained by the groups' background. These findings confirm that HCD is a valuable approach to tailor information to the target group. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Skonieczna, Katarzyna; Styczyński, Jan; Krenska, Anna; Wysocki, Mariusz; Jakubowska, Aneta; Grzybowski, Tomasz
2016-01-01
Aim of the study: In recent years, RNA analysis has been increasingly used in clinical and forensic genetics. Nevertheless, a major limitation of RNA-based applications is very low RNA stability in biological material, due to the RNAse activity. This highlights the need for improving the methods of RNA collection and storage. Technological approaches such as FTA Classic Cards (Whatman) could provide a solution for the problem of RNA degradation. However, different methods of RNA isolation from FTA cards could have diverse effects on RNA quantity and quality. The purpose of this research was to analyze the utility of three different methods of RNA isolation from peripheral blood collected on FTA Classic Cards (Whatman). The study also aimed at assessing RNA stability in bloodstains deposited on FTA cards. Material and methods: The study was performed on peripheral bloodstains collected from 59 individuals on FTA Classic Cards (Whatman). RNA was isolated with High Pure RNA Isolation Kit (Roche Diagnostics), Universal RNA/miRNA Purification (EURx) and TRIzol Reagent (Life Technologies). RNA was subjected to quantitative analysis followed by reverse transcription and Real - Time PCR reaction. Results: The study has shown that FTA Classic Cards (Whatman) are useful tools for storing bloodstains at room temperature for RNA analysis. Moreover, the method of RNA extraction employing TRIzol Reagent (Life Technologies) provides the highest efficiency and reproducibility for samples stored for no more than 2 years. Conclusions: The FTA cards are suitable for collecting and storing bloodstains for RNA analysis in clinical and forensic genetics.
Development of Data Acquisition Card Driver for ICRH System on EAST
NASA Astrophysics Data System (ADS)
Liu, Daming; Luo, Jiarong; Zhao, Yanping; Qin, Chengming
2008-04-01
Presented in this paper is the development of the driver for the data acquisition card with a peripheral component interconnection (PCI) local bus on the ion cyclotron range of frequency heating (ICRH) system. The driver is mainly aimed at the embedded VxWorks system (real-time operating system) which is widely used in various fields of real-time systems. An efficient way is employed to develop this driver, which will advance the real-time control of the ICRH system on the experimental advanced superconductor tokamak (EAST). The driver is designed using the TORNADO integrated development environment (IDE), and implemented in C plus language. The details include the hardware configuration, analogue/digital (A/D) and digital/analogue (D/A) conversion, input and output (I/O) operation of the driver to support over five cards. The data acquisition card can be manipulated in a low-level program and meet the requirements of A/D conversion and D/A outputs.
Bengtsson, Linus; Lu, Xin; Thorson, Anna; Garfield, Richard; von Schreeb, Johan
2011-01-01
Background Population movements following disasters can cause important increases in morbidity and mortality. Without knowledge of the locations of affected people, relief assistance is compromised. No rapid and accurate method exists to track population movements after disasters. We used position data of subscriber identity module (SIM) cards from the largest mobile phone company in Haiti (Digicel) to estimate the magnitude and trends of population movements following the Haiti 2010 earthquake and cholera outbreak. Methods and Findings Geographic positions of SIM cards were determined by the location of the mobile phone tower through which each SIM card connects when calling. We followed daily positions of SIM cards 42 days before the earthquake and 158 days after. To exclude inactivated SIM cards, we included only the 1.9 million SIM cards that made at least one call both pre-earthquake and during the last month of study. In Port-au-Prince there were 3.2 persons per included SIM card. We used this ratio to extrapolate from the number of moving SIM cards to the number of moving persons. Cholera outbreak analyses covered 8 days and tracked 138,560 SIM cards. An estimated 630,000 persons (197,484 Digicel SIM cards), present in Port-au-Prince on the day of the earthquake, had left 19 days post-earthquake. Estimated net outflow of people (outflow minus inflow) corresponded to 20% of the Port-au-Prince pre-earthquake population. Geographic distribution of population movements from Port-au-Prince corresponded well with results from a large retrospective, population-based UN survey. To demonstrate feasibility of rapid estimates and to identify areas at potentially increased risk of outbreaks, we produced reports on SIM card movements from a cholera outbreak area at its immediate onset and within 12 hours of receiving data. Conclusions Results suggest that estimates of population movements during disasters and outbreaks can be delivered rapidly and with potentially high validity in areas with high mobile phone use. Please see later in the article for the Editors' Summary PMID:21918643
Using Guided Notes, Choral Responding, and Response Cards to Increase Student Performance
ERIC Educational Resources Information Center
Blackwell, Ann J.; McLaughlin, T. F.
2005-01-01
This paper presents and selectively reviews the data-based literature regarding guided notes, choral responding, and response cards (ASR). These ASR procedures as designed to increase the opportunities for students to respond and improve their academic performance. Each of these procedures were effective in increasing student performance in…
ERIC Educational Resources Information Center
Harris, Julian; Maurer, Hermann
An investigation into high level event monitoring within the scope of a well-known multimedia application, HyperCard--a program on the Macintosh computer, is carried out. A monitoring system is defined as a system which automatically monitors usage of some activity and gathers statistics based on what is has observed. Monitor systems can give the…
Fall 1972 University Racial Census.
ERIC Educational Resources Information Center
Brooks, Glenwood C., Jr.; Sedlacek, William E.
This document reports the results of the fall 1972 racial census at the University of Maryland. Only new freshmen, transfer students, and readmitted students filled out the racial census cards. All returning students constituted the data base of the student body. By adding new and deleting old racial census cards, counts could be made. Results of…
Report Card on the Effectiveness of Teacher Training Programs
ERIC Educational Resources Information Center
Tennessee State Board of Education, 2010
2010-01-01
Tennessee Code Annotated 49-5-108 requires the state to develop a report card or assessment on the effectiveness of teacher training programs. This report includes data on the performance of each institution's graduates in the following areas required by state statute: placement and retention rates, Praxis results, and teacher effect data based on…
Collecting Social Network Data from Mobile Phone SIM Cards
ERIC Educational Resources Information Center
Peseckas, Ryan
2016-01-01
I used a subscriber identity module card reader to copy the lists of saved contacts from 170 mobile phones in Fiji. This approach has both advantages and disadvantages compared to other techniques for collecting telephone network data. Copying phone contacts avoids recall biases associated with survey-based name generators. It also obviates the…
ERIC Educational Resources Information Center
Moore, Darren A.; Whittaker, Sarah; Ford, Tamsin J.
2016-01-01
This paper describes daily report cards and the evidence relating to their use in schools for children with attention-deficit/hyperactivity disorder (ADHD). This intervention typically involves teachers evaluating a student's behaviour at school against pre-determined targets and parents subsequently providing reinforcement at home for positive…
ERIC Educational Resources Information Center
Brown, Charles I., Ed.
The major theme of Report Card 1 is enrollment projections. Reports in this section include: Barwick and Stafford's "Statewide Enrollment Projections for North Carolina, 1975-80"; Reiman's "Assumption-Based Model for Developing Institutional Enrollment Projections"; Rajasekhara's "Enrollment Projection," dealing with alternative methods;…
BMI Health Report Cards: Parents' Perceptions and Reactions.
Jones, Marla; Huffer, Cassie; Adams, Tom; Jones, Logan; Church, Bryan
2017-12-01
In 2003, Arkansas became the first state to require body mass index (BMI) testing in public schools to raise awareness of the growing obesity epidemic among children and adolescents. Limited information exists regarding the effectiveness of school-based BMI screening programs. The purpose of this study was to determine if BMI health report cards affected parents' knowledge or actions regarding their child's health and to determine the accuracy of parents' perceptions of their child as underweight, normal weight, or overweight according to their child's BMI. A questionnaire was developed with the help of physical educators, pediatricians, and exercise scientists to determine parents' perceptions and behaviors regarding BMI report cards. The questionnaire was distributed to parents/guardians of children who sought medical care at two pediatrician's offices in Arkansas. Based on responses to survey questions, parents are not making changes to their child's diet and exercise habits if their child is classified as "at risk" or "overweight." However, parents did report that BMI health report cards are influencing their knowledge about their child's health. The majority of parents in the study (approximately 66%) did not accurately perceive their child's BMI category.
`Membership Has Its Privileges': Status Incentives and Categorical Inequality in Education
Domina, Thurston; Penner, Andrew M.; Penner, Emily K.
2015-01-01
Prizes – formal systems that publicly allocate rewards for exemplary behavior – play an increasingly important role in a wide array of social settings, including education. In this paper, we evaluate a prize system designed to boost achievement at two high schools by assigning students color-coded ID cards based on a previously low stakes test. Average student achievement on this test increased in the ID card schools beyond what one would expect from contemporaneous changes in neighboring schools. However, regression discontinuity analyses indicate that the program created new inequalities between students who received low-status and high-status ID cards. These findings indicate that status-based incentives create categorical inequalities between prize winners and others even as they reorient behavior toward the goals they reward. PMID:27213170
Cardiac surgery report cards: comprehensive review and statistical critique.
Shahian, D M; Normand, S L; Torchiana, D F; Lewis, S M; Pastore, J O; Kuntz, R E; Dreyer, P I
2001-12-01
Public report cards and confidential, collaborative peer education represent distinctly different approaches to cardiac surgery quality assessment and improvement. This review discusses the controversies regarding their methodology and relative effectiveness. Report cards have been the more commonly used approach, typically as a result of state legislation. They are based on the presumption that publication of outcomes effectively motivates providers, and that market forces will reward higher quality. Numerous studies have challenged the validity of these hypotheses. Furthermore, although states with report cards have reported significant decreases in risk-adjusted mortality, it is unclear whether this improvement resulted from public disclosure or, rather, from the development of internal quality programs by hospitals. An additional confounding factor is the nationwide decline in heart surgery mortality, including states without quality monitoring. Finally, report cards may engender negative behaviors such as high-risk case avoidance and "gaming" of the reporting system, especially if individual surgeon results are published. The alternative approach, continuous quality improvement, may provide an opportunity to enhance performance and reduce interprovider variability while avoiding the unintended negative consequences of report cards. This collaborative method, which uses exchange visits between programs and determination of best practice, has been highly effective in northern New England and in the Veterans Affairs Administration. However, despite their potential advantages, quality programs based solely on confidential continuous quality improvement do not address the issue of public accountability. For this reason, some states may continue to mandate report cards. In such instances, it is imperative that appropriate statistical techniques and report formats are used, and that professional organizations simultaneously implement continuous quality improvement programs. The statistical methodology underlying current report cards is flawed, and does not justify the degree of accuracy presented to the public. All existing risk-adjustment methods have substantial inherent imprecision, and this is compounded when the results of such patient-level models are aggregated and used inappropriately to assess provider performance. Specific problems include sample size differences, clustering of observations, multiple comparisons, and failure to account for the random component of interprovider variability. We advocate the use of hierarchical or multilevel statistical models to address these concerns, as well as report formats that emphasize the statistical uncertainty of the results.
Controlling front-end electronics boards using commercial solutions
NASA Astrophysics Data System (ADS)
Beneyton, R.; Gaspar, C.; Jost, B.; Schmeling, S.
2002-04-01
LHCb is a dedicated B-physics experiment under construction at CERN's large hadron collider (LHC) accelerator. This paper will describe the novel approach LHCb is taking toward controlling and monitoring of electronics boards. Instead of using the bus in a crate to exercise control over the boards, we use credit-card sized personal computers (CCPCs) connected via Ethernet to cheap control PCs. The CCPCs will provide a simple parallel, I2C, and JTAG buses toward the electronics board. Each board will be equipped with a CCPC and, hence, will be completely independently controlled. The advantages of this scheme versus the traditional bus-based scheme will be described. Also, the integration of the controls of the electronics boards into a commercial supervisory control and data acquisition (SCADA) system will be shown.
26 CFR 301.6311-2 - Payment by credit card and debit card.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 26 Internal Revenue 18 2012-04-01 2012-04-01 false Payment by credit card and debit card. 301.6311....6311-2 Payment by credit card and debit card. (a) Authority to receive—(1) Payments by credit card and debit card. Internal revenue taxes may be paid by credit card or debit card as authorized by this...
26 CFR 301.6311-2 - Payment by credit card and debit card.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 26 Internal Revenue 18 2011-04-01 2011-04-01 false Payment by credit card and debit card. 301.6311....6311-2 Payment by credit card and debit card. (a) Authority to receive—(1) Payments by credit card and debit card. Internal revenue taxes may be paid by credit card or debit card as authorized by this...
26 CFR 301.6311-2 - Payment by credit card and debit card.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 26 Internal Revenue 18 2013-04-01 2013-04-01 false Payment by credit card and debit card. 301.6311....6311-2 Payment by credit card and debit card. (a) Authority to receive—(1) Payments by credit card and debit card. Internal revenue taxes may be paid by credit card or debit card as authorized by this...
26 CFR 301.6311-2 - Payment by credit card and debit card.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 26 Internal Revenue 18 2014-04-01 2014-04-01 false Payment by credit card and debit card. 301.6311....6311-2 Payment by credit card and debit card. (a) Authority to receive—(1) Payments by credit card and debit card. Internal revenue taxes may be paid by credit card or debit card as authorized by this...
7 CFR 274.5 - Record retention and forms security.
Code of Federal Regulations, 2014 CFR
2014-01-01
... reconciliation process. (c) Accountable documents. (1) EBT cards shall be considered accountable documents. The... validation of inventory controls and records by parties not otherwise involved in maintaining control records...
7 CFR 274.5 - Record retention and forms security.
Code of Federal Regulations, 2013 CFR
2013-01-01
... reconciliation process. (c) Accountable documents. (1) EBT cards shall be considered accountable documents. The... validation of inventory controls and records by parties not otherwise involved in maintaining control records...
7 CFR 274.5 - Record retention and forms security.
Code of Federal Regulations, 2012 CFR
2012-01-01
... reconciliation process. (c) Accountable documents. (1) EBT cards shall be considered accountable documents. The... validation of inventory controls and records by parties not otherwise involved in maintaining control records...
ERIC Educational Resources Information Center
Zuzack, Christine A.
1997-01-01
Enhanced magnetic strip cards and "smart cards" offer varied service options to college students. Enhanced magnetic strip cards serve as cash cards and provide access to services. Smart cards, which resemble credit cards but contain a microchip, can be used as phone cards, bus passes, library cards, admission tickets, point-of-sale debit…
Use of FTA® classic cards for epigenetic analysis of sperm DNA.
Serra, Olga; Frazzi, Raffaele; Perotti, Alessio; Barusi, Lorenzo; Buschini, Annamaria
2018-02-01
FTA® technologies provide the most reliable method for DNA extraction. Although FTA technologies have been widely used for genetic analysis, there is no literature on their use for epigenetic analysis yet. We present for the first time, a simple method for quantitative methylation assessment based on sperm cells stored on Whatman FTA classic cards. Specifically, elution of seminal DNA from FTA classic cards was successfully tested with an elution buffer and an incubation step in a thermocycler. The eluted DNA was bisulfite converted, amplified by PCR, and a region of interest was pyrosequenced.
An Anonymous Credit Card System
NASA Astrophysics Data System (ADS)
Androulaki, Elli; Bellovin, Steven
Credit cards have many important benefits; however, these same benefits often carry with them many privacy concerns. In particular, the need for users to be able to monitor their own transactions, as well as bank’s need to justify its payment requests from cardholders, entitle the latter to maintain a detailed log of all transactions its credit card customers were involved in. A bank can thus build a profile of each cardholder even without the latter’s consent. In this paper, we present a practical and accountable anonymous credit system based on ecash, with a privacy preserving mechanism for error correction and expense-reporting.
Medicare's Drug Discount Card Program: Beneficiaries' Experience with Choice
Hassol, Andrea; Wrobel, Marian V.; Doksum, Teresa
2007-01-01
This article describes Medicare beneficiaries' experience with the choice among Medicare drug discount cards and is based primarily on surveys and focus groups with beneficiaries as well as interviews with other stakeholders. Although competition and choice have the potential to reduce cost and enhance quality in the Medicare Program, our findings highlight some of the challenges involved in making choice work in practice. Despite the unique and temporary nature of the drug discount card program, these findings have considerable relevance to the Part D drug benefit and to other Medicare initiatives that rely on choice. PMID:17722747
Multi-channel Scaler Cards Improve Data Collection
NASA Technical Reports Server (NTRS)
2004-01-01
Scientists interested in exploring the intricacies and dynamics of Earth's climate and ecosystems continually need smaller, lighter instrumentation that can be placed onboard various sensing platforms, such as Unmanned Aerial Vehicles (UAVs). Responding to a need for improved data collection for remote atmospheric measurement systems, ASRC Aerospace Corporation, of Greenbelt, Maryland, developed a series of low-power, highly integrated, multichannel scaler (MCS) cards. The cards were designed to meet the needs of NASA's ground-based and airborne Light Detection and Ranging (LIDAR) photoncounting programs. They can rapidly collect thousands of data points during a continuous scan of the atmosphere.
Operating a Geiger Müller tube using a PC sound card
NASA Astrophysics Data System (ADS)
Azooz, A. A.
2009-01-01
In this paper, a simple MATLAB-based PC program that enables the computer to function as a replacement for the electronic scalar-counter system associated with a Geiger-Müller (GM) tube is described. The program utilizes the ability of MATLAB to acquire data directly from the computer sound card. The signal from the GM tube is applied to the computer sound card via the line in port. All standard GM experiments, pulse shape and statistical analysis experiments can be carried out using this system. A new visual demonstration of dead time effects is also presented.
Pholwat, Suporn; Liu, Jie; Stroup, Suzanne; Gratz, Jean; Banu, Sayera; Rahman, S M Mazidur; Ferdous, Sara Sabrina; Foongladda, Suporn; Boonlert, Duangjai; Ogarkov, Oleg; Zhdanova, Svetlana; Kibiki, Gibson; Heysell, Scott; Houpt, Eric
2015-02-24
Genotypic methods for drug susceptibility testing of Mycobacterium tuberculosis are desirable to speed the diagnosis and proper therapy of tuberculosis (TB). However, the numbers of genes and polymorphisms implicated in resistance have proliferated, challenging diagnostic design. We developed a microfluidic TaqMan array card (TAC) that utilizes both sequence-specific probes and high-resolution melt analysis (HRM), providing two layers of detection of mutations. Twenty-seven primer pairs and 40 probes were designed to interrogate 3,200 base pairs of critical regions of the inhA, katG, rpoB, embB, rpsL, rrs, eis, gyrA, gyrB, and pncA genes. The method was evaluated on 230 clinical M. tuberculosis isolates from around the world, and it yielded 96.1% accuracy (2,431/2,530) in comparison to that of Sanger sequencing and 87% accuracy in comparison to that of the slow culture-based susceptibility testing. This TAC-HRM method integrates assays for 10 genes to yield fast, comprehensive, and accurate drug susceptibility results for the 9 major antibiotics used to treat TB and could be deployed to improve treatment outcomes. Multidrug-resistant tuberculosis threatens global tuberculosis control efforts. Optimal therapy utilizes susceptibility test results to guide individualized treatment regimens; however, the susceptibility testing methods in use are technically difficult and slow. We developed an integrated TaqMan array card method with high-resolution melt analysis that interrogates 10 genes to yield a fast, comprehensive, and accurate drug susceptibility result for the 9 major antituberculosis antibiotics. Copyright © 2015 Pholwat et al.
Effectiveness of Organ Donation Information Campaigns in Germany: A Facebook Based Online Survey.
Terbonssen, Tobias; Settmacher, Utz; Wurst, Christine; Dirsch, Olaf; Dahmen, Uta
2015-07-28
The German transplantation system is in a crisis due to a lack of donor organs. Information campaigns are one of the main approaches to increase organ donation rates. Since 2012, German health insurance funds are obliged by law to inform their members about organ donation. We raised the hypothesis: The willingness to sign a donor card rises due to the subsequent increase of specific knowledge by receiving the information material of the health insurance funds. The objective of the study was to assess the influence of information campaigns on the specific knowledge and the willingness to donate organs. We conducted an online survey based on recruitment via Facebook groups, advertisements using the snowball effect, and on mailing lists of medical faculties in Germany. Besides the demographic data, the willingness to hold an organ donor card was investigated. Specific knowledge regarding transplantation was explored using five factual questions resulting in a specific knowledge score. We recruited a total of 2484 participants, of which 32.7% (300/917) had received information material. Mean age was 29.9 (SD 11.0, median 26.0). There were 65.81% (1594/2422) of the participants that were female. The mean knowledge score was 3.28 of a possible 5.00 (SD 1.1, median 3.0). Holding a donor card was associated with specific knowledge (P<.001), but not with the general education level (P=.155). Receiving information material was related to holding a donor card (P<.001), but not to a relevant increase in specific knowledge (difference in mean knowledge score 3.20 to 3.48, P=.006). The specific knowledge score and the percentage of organ donor card holders showed a linear association (P<.001). The information campaign was not associated with a relevant increase in specific knowledge, but with an increased rate in organ donor card holders. This effect is most likely related to the feeling of being informed, together with an easy access to the organ donor card.
Liu, Jie; Ochieng, Caroline; Wiersma, Steve; Ströher, Ute; Towner, Jonathan S; Whitmer, Shannon; Nichol, Stuart T; Moore, Christopher C; Kersh, Gilbert J; Kato, Cecilia; Sexton, Christopher; Petersen, Jeannine; Massung, Robert; Hercik, Christine; Crump, John A; Kibiki, Gibson; Maro, Athanasia; Mujaga, Buliga; Gratz, Jean; Jacob, Shevin T; Banura, Patrick; Scheld, W Michael; Juma, Bonventure; Onyango, Clayton O; Montgomery, Joel M; Houpt, Eric; Fields, Barry
2016-01-01
Acute febrile illness (AFI) is associated with substantial morbidity and mortality worldwide, yet an etiologic agent is often not identified. Convalescent-phase serology is impractical, blood culture is slow, and many pathogens are fastidious or impossible to cultivate. We developed a real-time PCR-based TaqMan array card (TAC) that can test six to eight samples within 2.5 h from sample to results and can simultaneously detect 26 AFI-associated organisms, including 15 viruses (chikungunya, Crimean-Congo hemorrhagic fever [CCHF] virus, dengue, Ebola virus, Bundibugyo virus, Sudan virus, hantaviruses [Hantaan and Seoul], hepatitis E, Marburg, Nipah virus, o'nyong-nyong virus, Rift Valley fever virus, West Nile virus, and yellow fever virus), 8 bacteria (Bartonella spp., Brucella spp., Coxiella burnetii, Leptospira spp., Rickettsia spp., Salmonella enterica and Salmonella enterica serovar Typhi, and Yersinia pestis), and 3 protozoa (Leishmania spp., Plasmodium spp., and Trypanosoma brucei). Two extrinsic controls (phocine herpesvirus 1 and bacteriophage MS2) were included to ensure extraction and amplification efficiency. Analytical validation was performed on spiked specimens for linearity, intra-assay precision, interassay precision, limit of detection, and specificity. The performance of the card on clinical specimens was evaluated with 1,050 blood samples by comparison to the individual real-time PCR assays, and the TAC exhibited an overall 88% (278/315; 95% confidence interval [CI], 84% to 92%) sensitivity and a 99% (5,261/5,326, 98% to 99%) specificity. This TaqMan array card can be used in field settings as a rapid screen for outbreak investigation or for the surveillance of pathogens, including Ebola virus. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Bannerman, J A; Costamagna, A C; McCornack, B P; Ragsdale, D W
2015-06-01
Generalist natural enemies play an important role in controlling soybean aphid, Aphis glycines (Hemiptera: Aphididae), in North America. Several sampling methods are used to monitor natural enemy populations in soybean, but there has been little work investigating their relative bias, precision, and efficiency. We compare five sampling methods: quadrats, whole-plant counts, sweep-netting, walking transects, and yellow sticky cards to determine the most practical methods for sampling the three most prominent species, which included Harmonia axyridis (Pallas), Coccinella septempunctata L. (Coleoptera: Coccinellidae), and Orius insidiosus (Say) (Hemiptera: Anthocoridae). We show an important time by sampling method interaction indicated by diverging community similarities within and between sampling methods as the growing season progressed. Similarly, correlations between sampling methods for the three most abundant species over multiple time periods indicated differences in relative bias between sampling methods and suggests that bias is not consistent throughout the growing season, particularly for sticky cards and whole-plant samples. Furthermore, we show that sticky cards produce strongly biased capture rates relative to the other four sampling methods. Precision and efficiency differed between sampling methods and sticky cards produced the most precise (but highly biased) results for adult natural enemies, while walking transects and whole-plant counts were the most efficient methods for detecting coccinellids and O. insidiosus, respectively. Based on bias, precision, and efficiency considerations, the most practical sampling methods for monitoring in soybean include walking transects for coccinellid detection and whole-plant counts for detection of small predators like O. insidiosus. Sweep-netting and quadrat samples are also useful for some applications, when efficiency is not paramount. © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Controller and data acquisition system for SIDECAR ASIC driven HAWAII detectors
NASA Astrophysics Data System (ADS)
Ramaprakash, Anamparambu; Burse, Mahesh; Chordia, Pravin; Chillal, Kalpesh; Kohok, Abhay; Mestry, Vilas; Punnadi, Sujit; Sinha, Sakya
2010-07-01
SIDECAR is an Application Specific Integrated Circuit (ASIC), which can be used for control and data acquisition from near-IR HAWAII detectors offered by Teledyne Imaging Sensors (TIS), USA. The standard interfaces provided by Teledyne are COM API and socket servers running under MS Windows platform. These interfaces communicate to the ASIC (and the detector) through an intermediate card called JWST ASIC Drive Electronics (JADE2). As part of an ongoing programme of several years, for developing astronomical focal plane array (CCDs, CMOS and Hybrid) controllers and data acquisition systems (CDAQs), IUCAA is currently developing the next generation controllers employing Virtex-5 family FPGA devices. We present here the capabilities which are built into these new CDAQs for handling HAWAII detectors. In our system, the computer which hosts the application programme, user interface and device drivers runs on a Linux platform. It communicates through a hot-pluggable USB interface (with an optional optical fibre extender) to the FPGA-based card which replaces the JADE2. The FPGA board in turn, controls the SIDECAR ASIC and through it a HAWAII-2RG detector, both of which are located in a cryogenic test Dewar set up which is liquid nitrogen cooled. The system can acquire data over 1, 4, or 32 readout channels, with or without binning, at different speeds, can define sub-regions for readout, offers various readout schemes like Fowler sampling, up-theramp etc. In this paper, we present the performance results obtained from a prototype system.
Performance of patients with schizophrenia on the Wisconsin Card Sorting Test (WCST).
Everett, J; Lavoie, K; Gagnon, J F; Gosselin, N
2001-03-01
To directly compare the performance of patients with schizophrenia and control subjects on the Wisconsin Card Sorting Test (WCST). Specifically, we sought to verify if there are significant differences on the "classical" WCST measurements (perseverative errors and number of categories), as well as on more rarely reported scores, and assess the extent to which patients with schizophrenia can improve their performance with card-by-card instructions and continuous verbal reinforcement. Prospective cross-sectional study. Psychiatry department in a university-affiliated hospital. 30 patients with schizophrenia, diagnosed according to DSM-IV criteria, and 30 control subjects, matched to patients according to age and education. The WCST was administered according to the criteria of Heaton, and a subgroup of the patients with schizophrenia was given a retest after an explanation of the WCST and verbal reinforcements. Patients with schizophrenia succeeded on fewer categories (t = 23.3, p < 0.001), committed more perseverative errors (t = 15.6, p < 0.001), made more perseverative responses (t = 14.6, p < 0.001), needed more trials to succeed at the first category (t = 9.2, p < 0.003) and gave significantly lower conceptual level responses (t = 14.1, p < 0.001) than the controls. However, on retest, patients with schizophrenia committed significantly fewer perseverative errors (t = 5.1, p < 0.001) and showed higher conceptual level responses (t = -3.45, p < 0.003). Consistent with a hypothesis of frontal dysfunction in schizophrenia, patients with schizophrenia tend to show a perseverative deficit; however, some are able to partially overcome this deficit when given verbal reinforcement.
Performance of patients with schizophrenia on the Wisconsin Card Sorting Test (WCST).
Everett, J; Lavoie, K; Gagnon, J F; Gosselin, N
2001-01-01
OBJECTIVE: To directly compare the performance of patients with schizophrenia and control subjects on the Wisconsin Card Sorting Test (WCST). Specifically, we sought to verify if there are significant differences on the "classical" WCST measurements (perseverative errors and number of categories), as well as on more rarely reported scores, and assess the extent to which patients with schizophrenia can improve their performance with card-by-card instructions and continuous verbal reinforcement. DESIGN: Prospective cross-sectional study. SETTING: Psychiatry department in a university-affiliated hospital. PARTICIPANTS: 30 patients with schizophrenia, diagnosed according to DSM-IV criteria, and 30 control subjects, matched to patients according to age and education. INTERVENTION: The WCST was administered according to the criteria of Heaton, and a subgroup of the patients with schizophrenia was given a retest after an explanation of the WCST and verbal reinforcements. RESULTS: Patients with schizophrenia succeeded on fewer categories (t = 23.3, p < 0.001), committed more perseverative errors (t = 15.6, p < 0.001), made more perseverative responses (t = 14.6, p < 0.001), needed more trials to succeed at the first category (t = 9.2, p < 0.003) and gave significantly lower conceptual level responses (t = 14.1, p < 0.001) than the controls. However, on retest, patients with schizophrenia committed significantly fewer perseverative errors (t = 5.1, p < 0.001) and showed higher conceptual level responses (t = -3.45, p < 0.003). CONCLUSION: Consistent with a hypothesis of frontal dysfunction in schizophrenia, patients with schizophrenia tend to show a perseverative deficit; however, some are able to partially overcome this deficit when given verbal reinforcement. PMID:11291529
Navigation of military and space unmanned ground vehicles in unstructured terrains
NASA Technical Reports Server (NTRS)
Lescoe, Paul; Lavery, David; Bedard, Roger
1991-01-01
Development of unmanned vehicles for local navigation in terrains unstructured by humans is reviewed. Modes of navigation include teleoperation or remote control, computer assisted remote driving (CARD), and semiautonomous navigation (SAN). A first implementation of a CARD system was successfully tested using the Robotic Technology Test Vehicle developed by Jet Propulsion Laboratory. Stereo pictures were transmitted to a remotely located human operator, who performed the sensing, perception, and planning functions of navigation. A computer provided range and angle measurements and the path plan was transmitted to the vehicle which autonomously executed the path. This implementation is to be enhanced by providing passive stereo vision and a reflex control system for autonomously stopping the vehicle if blocked by an obstacle. SAN achievements include implementation of a navigation testbed on a six wheel, three-body articulated rover vehicle, development of SAN algorithms and code, integration of SAN software onto the vehicle, and a successful feasibility demonstration that represents a step forward towards the technology required for long-range exploration of the lunar or Martian surface. The vehicle includes a passive stereo vision system with real-time area-based stereo image correlation, a terrain matcher, a path planner, and a path execution planner.
Neural fraud detection in credit card operations.
Dorronsoro, J R; Ginel, F; Sgnchez, C; Cruz, C S
1997-01-01
This paper presents an online system for fraud detection of credit card operations based on a neural classifier. Since it is installed in a transactional hub for operation distribution, and not on a card-issuing institution, it acts solely on the information of the operation to be rated and of its immediate previous history, and not on historic databases of past cardholder activities. Among the main characteristics of credit card traffic are the great imbalance between proper and fraudulent operations, and a great degree of mixing between both. To ensure proper model construction, a nonlinear version of Fisher's discriminant analysis, which adequately separates a good proportion of fraudulent operations away from other closer to normal traffic, has been used. The system is fully operational and currently handles more than 12 million operations per year with very satisfactory results.
Paper-based archiving of biological samples from fish for detecting betanodavirus.
Navaneeth Krishnan, A; Bhuvaneswari, T; Ezhil Praveena, P; Jithendran, K P
2016-07-01
This study was carried out to evaluate the efficiency of the Flinders Technology Associates (FTA(®)) card (Whatman(®)) as a sampling device and storage platform for RNA from betanodavirus-infected biological samples (viz., larvae, broodstock, cell culture supernatants and rearing seawater spiked with infected materials). The study showed that FTA cards can be used to detect betanodaviruses by reverse transcription-polymerase chain reaction (RT-PCR). The diagnostic efficiency of RT-PCR from all sample types on FTA cards decreased after 21 days of storage at 4 °C, although the virus could be detected up to 28 days by nested RT-PCR. The FTA card protocol thus provides a supplementary method for quick and easy collection of samples, preservation of RNA on a dry storage basis, and detection of betanodavirus-infected fish.
RFID - based Staff Control System (SCS) in Kazakhstan
NASA Astrophysics Data System (ADS)
Saparkhojayev, N.
2015-06-01
RFID - based Staff Control System (SCS) will allow complete hands-free access control, monitoring the whereabouts of employee and record the attendance of the employee as well. Moreover, with a help of this system, it is possible to have a nice report at the end of the month and based on the total number of worked hours, the salary will be allocated to each personnel. The access tag can be read up to 10 centimeters from the RFID reader. The proposed system is based on UHF RFID readers, supported with antennas at gate and transaction sections, and employee identification cards containing RFID-transponders which are able to electronically store information that can be read / written even without the physical contact with the help of radio medium. This system is an innovative system, which describes the benefits of applying RFID- technology in the Education System process of Republic of Kazakhstan. This paper presents the experiments conducted to set up RFID based SCS.
Comparison of DNA preservation methods for environmental bacterial community samples.
Gray, Michael A; Pratte, Zoe A; Kellogg, Christina A
2013-02-01
Field collections of environmental samples, for example corals, for molecular microbial analyses present distinct challenges. The lack of laboratory facilities in remote locations is common, and preservation of microbial community DNA for later study is critical. A particular challenge is keeping samples frozen in transit. Five nucleic acid preservation methods that do not require cold storage were compared for effectiveness over time and ease of use. Mixed microbial communities of known composition were created and preserved by DNAgard(™), RNAlater(®), DMSO-EDTA-salt (DESS), FTA(®) cards, and FTA Elute(®) cards. Automated ribosomal intergenic spacer analysis and clone libraries were used to detect specific changes in the faux communities over weeks and months of storage. A previously known bias in FTA(®) cards that results in lower recovery of pure cultures of Gram-positive bacteria was also detected in mixed community samples. There appears to be a uniform bias across all five preservation methods against microorganisms with high G + C DNA. Overall, the liquid-based preservatives (DNAgard(™), RNAlater(®), and DESS) outperformed the card-based methods. No single liquid method clearly outperformed the others, leaving method choice to be based on experimental design, field facilities, shipping constraints, and allowable cost. © 2012 Federation of European Microbiological Societies. Published by Blackwell Publishing Ltd. All rights reserved.
Bohil, Corey J; Higgins, Nicholas A; Keebler, Joseph R
2014-01-01
We compared methods for predicting and understanding the source of confusion errors during military vehicle identification training. Participants completed training to identify main battle tanks. They also completed card-sorting and similarity-rating tasks to express their mental representation of resemblance across the set of training items. We expected participants to selectively attend to a subset of vehicle features during these tasks, and we hypothesised that we could predict identification confusion errors based on the outcomes of the card-sort and similarity-rating tasks. Based on card-sorting results, we were able to predict about 45% of observed identification confusions. Based on multidimensional scaling of the similarity-rating data, we could predict more than 80% of identification confusions. These methods also enabled us to infer the dimensions receiving significant attention from each participant. This understanding of mental representation may be crucial in creating personalised training that directs attention to features that are critical for accurate identification. Participants completed military vehicle identification training and testing, along with card-sorting and similarity-rating tasks. The data enabled us to predict up to 84% of identification confusion errors and to understand the mental representation underlying these errors. These methods have potential to improve training and reduce identification errors leading to fratricide.
Haghani, Fariba; Hatef Khorami, Mohammad; Fakhari, Mohammad
2016-07-01
Feedback cards are recommended as a feasible tool for structured written feedback delivery in clinical education while effectiveness of this tool on the medical students' performance is still questionable. The purpose of this study was to compare the effects of structured written feedback by cards as well as verbal feedback versus verbal feedback alone on the clinical performance of medical students at the Mini Clinical Evaluation Exercise (Mini-CEX) test in an outpatient clinic. This is a quasi-experimental study with pre- and post-test comprising four groups in two terms of medical students' externship. The students' performance was assessed through the Mini-Clinical Evaluation Exercise (Mini-CEX) as a clinical performance evaluation tool. Structured written feedbacks were given to two experimental groups by designed feedback cards as well as verbal feedback, while in the two control groups feedback was delivered verbally as a routine approach in clinical education. By consecutive sampling method, 62 externship students were enrolled in this study and seven students were excluded from the final analysis due to their absence for three days. According to the ANOVA analysis and Post Hoc Tukey test, no statistically significant difference was observed among the four groups at the pre-test, whereas a statistically significant difference was observed between the experimental and control groups at the post-test (F = 4.023, p =0.012). The effect size of the structured written feedbacks on clinical performance was 0.19. Structured written feedback by cards could improve the performance of medical students in a statistical sense. Further studies must be conducted in other clinical courses with longer durations.
Assessment of the RNASound RNA Sampling Card for the Preservation of Influenza Virus RNA
Lau, Hilda; Hurt, Aeron C.
2016-01-01
Shipping influenza virus specimens, isolates or purified RNA is normally conducted at ultra-low temperatures using dry ice to ensure minimal degradation of the samples but this is expensive and requires special packaging and shipping conditions. Therefore, alternative methods for shipping influenza viruses or RNA at ambient temperatures would be desirable. The RNASound RNA Sampling Card (FortiusBio LLC, San Diego, CA, USA) is a device that enables specimens or isolates to be applied to a card, whereby viruses are inactivated, while RNA is preserved and purified RNA can also easily be eluted. To evaluate this card, we applied influenza virus cell culture isolate supernatants to either the RNASound card or Whatman Grade No. 1 filter paper (GE Healthcare, Rydalmere, NSW, Australia) and compared the preservation to that of material stored in liquid form. Preservation was tested using influenza A and B viruses at two different storage temperatures [cool (2–8°C) or room temperature (18–22°C)] and these were compared with control material stored at -80°C, for 7, 14, or 28 days. The quality of the RNA recovered was assessed using real time RT-PCR and Sanger sequencing. The RNASound card was effective in preserving influenza RNA at room temperature for up to 28 days, with only a minor change in real-time RT-PCR cycle threshold values for selected gene targets when comparing between viruses applied to the card or stored at -80°C. Similar results were obtained with filter paper, whilst virus in liquid form performed the worst. Nevertheless, as the RNASound card also has the capability to inactivate viruses in addition to preserving RNA at room temperature for many weeks, this makes it feasible to send samples to laboratories using regular mail, and thus avoid the need for expensive shipping conditions requiring biohazard containers and dry ice. Moreover, the quick and simple RNA recovery from the RNASound card allows recipient labs to obtain RNA without the need for special reagents or equipment. PMID:27853455
3D multiplayer virtual pets game using Google Card Board
NASA Astrophysics Data System (ADS)
Herumurti, Darlis; Riskahadi, Dimas; Kuswardayan, Imam
2017-08-01
Virtual Reality (VR) is a technology which allows user to interact with the virtual environment. This virtual environment is generated and simulated by computer. This technology can make user feel the sensation when they are in the virtual environment. The VR technology provides real virtual environment view for user and it is not viewed from screen. But it needs another additional device to show the view of virtual environment. This device is known as Head Mounted Device (HMD). Oculust Rift and Microsoft Hololens are the most famous HMD devices used in VR. And in 2014, Google Card Board was introduced at Google I/O developers conference. Google Card Board is VR platform which allows user to enjoy the VR with simple and cheap way. In this research, we explore Google Card Board to develop simulation game of raising pet. The Google Card Board is used to create view for the VR environment. The view and control in VR environment is built using Unity game engine. And the simulation process is designed using Finite State Machine (FSM). This FSM can help to design the process clearly. So the simulation process can describe the simulation of raising pet well. Raising pet is fun activity. But sometimes, there are many conditions which cause raising pet become difficult to do, i.e. environment condition, disease, high cost, etc. this research aims to explore and implement Google Card Board in simulation of raising pet.
RTSPM: real-time Linux control software for scanning probe microscopy.
Chandrasekhar, V; Mehta, M M
2013-01-01
Real time computer control is an essential feature of scanning probe microscopes, which have become important tools for the characterization and investigation of nanometer scale samples. Most commercial (and some open-source) scanning probe data acquisition software uses digital signal processors to handle the real time data processing and control, which adds to the expense and complexity of the control software. We describe here scan control software that uses a single computer and a data acquisition card to acquire scan data. The computer runs an open-source real time Linux kernel, which permits fast acquisition and control while maintaining a responsive graphical user interface. Images from a simulated tuning-fork based microscope as well as a standard topographical sample are also presented, showing some of the capabilities of the software.
[Application of patient card technology to health care].
Sayag, E; Danon, Y L
1995-03-15
The potential benefits of patient card technology in improving management and delivery of health services have been explored. Patient cards can be used for numerous applications and functions: as a means of identification, as a key for an insurance payment system, and as a communication medium. Advanced card technologies allow for the storage of data on the card, creating the possibility of a comprehensive and portable patient record. There are many types of patient cards: paper or plastic cards, microfilm cards, bar-code cards, magnetic-strip cards and integrated circuit smart-cards. Choosing the right card depends on the amount of information to be stored, the degree of security required and the cost of the cards and their supporting infrastructure. Problems with patient cards are related to storage capacity, backup and data consistency, access authorization and ownership and compatibility. We think it is worth evaluating the place of patient card technology in the delivery of health services in Israel.
CAS. Controlled Access Security
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martinez, B.; Pomeroy, G.
1989-12-01
The Security Alarm System is a data acquisition and control system which collects data from intrusion sensors and displays the information in a real-time environment for operators. The Access Control System monitors and controls the movement of personnel with the use of card readers and biometrics hand readers.
Morgan, Amy J; Rapee, Ronald M; Bayer, Jordana K
2017-08-01
Background/aims Achieving a high response rate to follow-up questionnaires in randomized controlled trials of interventions is important for study validity. Few studies have tested the value of incentives in increasing response rates to online questionnaires in clinical trials of health interventions. This study evaluated the effect of a gift card prize-draw incentive on response rates to follow-up questionnaires within a trial of an online health intervention. Method The study was embedded in a host randomized controlled trial of an online parenting program for child anxiety. A total of 433 participants were randomly allocated to one of two groups: (1) being informed that they would enter a gift card prize-draw if they completed the final study questionnaire (24-week follow-up) and (2) not informed about the prize-draw. All participants had a 1 in 20 chance of winning an AUD50 gift card after they completed the online questionnaire. Results The odds of the informed group completing the follow-up questionnaire were significantly higher than the uninformed group, (79.6% vs 68.5%, odds ratio = 1.79, 95% confidence interval = 1.15-2.79). This response rate increase of 11.1% (95% confidence interval = 2.8-19.1) occurred in both intervention and control groups in the host randomized controlled trial. The incentive was also effective in increasing questionnaire commencement (84.6% vs 75.9%, odds ratio = 1.74, 95% confidence interval = 1.07-2.84) and reducing the delay in completing the questionnaire (19.9 vs 22.6 days, hazard ratio = 1.34, 95% confidence interval = 1.07-1.67). Conclusion This study adds to evidence for the effectiveness of incentives to increase response rates to follow-up questionnaires in health intervention trials.
Broadcast of four HD videos with LED ceiling lighting: optical-wireless MAC
NASA Astrophysics Data System (ADS)
Bouchet, Olivier; Porcon, Pascal; Gueutier, Eric
2011-09-01
The European project "hOME Gigabit Access Network" (OMEGA) targeted various wireless and wired solutions for 1 Gbit/s connectivity in Home Area Networks (HANs). One objective was to evaluate the suitability of optical wireless technologies in two spectral regions: visible light (visible-light communications - VLC) and near infrared (infrared communications - IRC). Several demonstrators have been built, all of them largely relying on overthe- shelf components. The demonstrators included a "wide-area" VLC broadcast link based on LED ceiling lighting and a laser-based high-data-rate "wide-area" IRC prototype. In this paper we discuss an adapted optical-wireless media-access-control (OWMAC) sublayer, which was developed and implemented during the project. It is suitable for both IRC and VLC. The VLC prototype is based on DMT signal processing and provides broadcasting at { 100 Mbit/s over an area of approximately 5 m2. The IRC prototype provides {300 Mbit/s half-duplex communication over an area of approximately 30 m2. The IRC mesh network, composed of one base station and two terminals, is based on OOK modulation, multi-sector transceivers, and an ultra-fast sector switch. After a brief discussion about the design of the optical-wireless data link layer and the optical-wireless switch (OWS) card, we address the card development and implementation. We also present applications for the VLC and IRC prototypes and measurement results regarding the MAC layer.
Wimmer, Lena; Bellingrath, Silja; von Stockhausen, Lisa
2016-01-01
The present paper reports a pilot study which tested cognitive effects of mindfulness practice in a theory-driven approach. Thirty-four fifth graders received either a mindfulness training which was based on the mindfulness-based stress reduction approach (experimental group), a concentration training (active control group), or no treatment (passive control group). Based on the operational definition of mindfulness by Bishop et al. (2004), effects on sustained attention, cognitive flexibility, cognitive inhibition, and data-driven as opposed to schema-based information processing were predicted. These abilities were assessed in a pre-post design by means of a vigilance test, a reversible figures test, the Wisconsin Card Sorting Test, a Stroop test, a visual search task, and a recognition task of prototypical faces. Results suggest that the mindfulness training specifically improved cognitive inhibition and data-driven information processing. PMID:27462287
Wimmer, Lena; Bellingrath, Silja; von Stockhausen, Lisa
2016-01-01
The present paper reports a pilot study which tested cognitive effects of mindfulness practice in a theory-driven approach. Thirty-four fifth graders received either a mindfulness training which was based on the mindfulness-based stress reduction approach (experimental group), a concentration training (active control group), or no treatment (passive control group). Based on the operational definition of mindfulness by Bishop et al. (2004), effects on sustained attention, cognitive flexibility, cognitive inhibition, and data-driven as opposed to schema-based information processing were predicted. These abilities were assessed in a pre-post design by means of a vigilance test, a reversible figures test, the Wisconsin Card Sorting Test, a Stroop test, a visual search task, and a recognition task of prototypical faces. Results suggest that the mindfulness training specifically improved cognitive inhibition and data-driven information processing.
Metacognitive Support Promotes an Effective Use of Instructional Resources in Intelligent Tutoring
ERIC Educational Resources Information Center
Schwonke, Rolf; Ertelt, Anna; Otieno, Christine; Renkl, Alexander; Aleven, Vincent; Salden, Ron J. C. M.
2013-01-01
We tested whether the provision of metacognitive knowledge on how to cope with the complexity of a learning environment improved learning. In an experimental setting, high-school students (N = 60) worked through a computer-based geometry lesson either with or without metacognitive support in the form of a cue card. This cue card encouraged…
The Reliability of Encounter Cards to Assess the CanMEDs Roles
ERIC Educational Resources Information Center
Sherbino, Jonathan; Kulasegaram, Kulamakan; Worster, Andrew; Norman, Geoffrey R.
2013-01-01
The purpose of this study was to determine the reliability of a computer-based encounter card (EC) to assess medical students during an emergency medicine rotation. From April 2011 to March 2012, multiple physicians assessed an entire medical school class during their emergency medicine rotation using the CanMEDS framework. At the end of an…
12 CFR Appendix M1 to Part 226 - Repayment Disclosures
Code of Federal Regulations, 2014 CFR
2014-01-01
... a fixed period of time, as set forth by the card issuer. (2) “Deferred interest or similar plan... calculating the minimum payment repayment estimate, card issuers must use the minimum payment formula(s) that... purchases, such as a “club plan purchase.” Also, assume that based on a consumer's balances in these...
12 CFR Appendix M1 to Part 226 - Repayment Disclosures
Code of Federal Regulations, 2012 CFR
2012-01-01
... of time, as set forth by the card issuer. (2) “Deferred interest or similar plan” means a plan where... payment repayment estimate, card issuers must use the minimum payment formula(s) that apply to a..., such as a “club plan purchase.” Also, assume that based on a consumer's balances in these features and...
12 CFR Appendix M1 to Part 226 - Repayment Disclosures
Code of Federal Regulations, 2011 CFR
2011-01-01
... of time, as set forth by the card issuer. (2) “Deferred interest or similar plan” means a plan where... payment repayment estimate, card issuers must use the minimum payment formula(s) that apply to a..., such as a “club plan purchase.” Also, assume that based on a consumer's balances in these features and...
12 CFR Appendix M1 to Part 226 - Repayment Disclosures
Code of Federal Regulations, 2013 CFR
2013-01-01
... a fixed period of time, as set forth by the card issuer. (2) “Deferred interest or similar plan... calculating the minimum payment repayment estimate, card issuers must use the minimum payment formula(s) that... purchases, such as a “club plan purchase.” Also, assume that based on a consumer's balances in these...
ERIC Educational Resources Information Center
Jurbergs, Nichole; Palcic, Jennette L.; Kelley, Mary L.
2010-01-01
Daily Behavior Report Cards (DBRC), which typically require teachers to evaluate students' daily behavior and parents to provide contingent consequences, are an effective and acceptable method for improving children's classroom behavior. The current study evaluated whether parent involvement is an essential treatment component or whether teacher…
ERIC Educational Resources Information Center
Forbes, Bethany E.; Skinner, Christopher H.; Black, Michelle P.; Yaw, Jared; Booher, Joshua; Delisle, Jean
2013-01-01
Using alternating treatments designs, we compared learning rates across 2 computer-based flash-card interventions (3?min each): a traditional drill intervention with 15 unknown words and an interspersal intervention with 12 known words and 3 unknown words. Each student acquired more words under the traditional drill intervention. Discussion…
A health plan report card for dentistry.
Bader, J D; Shugars, D A; Hayden, W J; White, B A
1996-01-01
Employers are demanding information about the performance of the health care plans they purchase for their employees. As a result, "report cards" are now beginning to appear that provide standardized, population-based comparison data for managed medical care plans' quality of care, access and member satisfaction, utilization, and financial status. Although report cards for dental care plans have not yet been developed, it is likely that purchasers will soon expect such performance information. A prototype report card for dental managed care plans is proposed in an effort to facilitate the development of a consensus standard for dentistry. The thirty-eight measures proposed for the report card are designed to be obtainable with a realistic level of additional effort in most dental practices. They were selected to provide data on questions of importance to purchasers and to assess processes and outcomes important because there is strong evidence for their effectiveness. The rationale for the measures is discussed, as are the steps required to develop more sophisticated measures. While the responsibility for the procurement of the information needed for dental report cards will die initially with administrators of dental care plans, it is likely in the near future that individual practitioners will be expected to supply this information to both individual patients and potential contractors.
Ahmed, Heba A; MacLeod, Ewan T; Hide, Geoff; Welburn, Susan C; Picozzi, Kim
2011-05-07
Diagnosis of blood borne infectious diseases relies primarily on the detection of the causative agent in the blood sample. Molecular techniques offer sensitive and specific tools for this although considerable difficulties exist when using these approaches in the field environment. In large scale epidemiological studies, FTA®cards are becoming increasingly popular for the rapid collection and archiving of a large number of samples. However, there are some difficulties in the downstream processing of these cards which is essential for the accurate diagnosis of infection. Here we describe recommendations for the best practice approach for sample processing from FTA®cards for the molecular diagnosis of trypanosomiasis using PCR. A comparison of five techniques was made. Detection from directly applied whole blood was less sensitive (35.6%) than whole blood which was subsequently eluted from the cards using Chelex®100 (56.4%). Better apparent sensitivity was achieved when blood was lysed prior to application on the FTA cards (73.3%) although this was not significant. This did not improve with subsequent elution using Chelex®100 (73.3%) and was not significantly different from direct DNA extraction from blood in the field (68.3%). Based on these results, the degree of effort required for each of these techniques and the difficulty of DNA extraction under field conditions, we recommend that blood is transferred onto FTA cards whole followed by elution in Chelex®100 as the best approach.
Clinical evaluation of the Vitek ANI card for identification of anaerobic bacteria.
Schreckenberger, P C; Celig, D M; Janda, W M
1988-01-01
An evaluation of the Vitek Anaerobe Identification (ANI) card was performed with 341 bacterial isolates, including 313 clinical isolates and 28 stock strains of anaerobic microorganisms. Identifications obtained with the ANI card were compared with those determined by conventional methods. The card identified 73.2% of 149 anaerobic gram-negative bacilli, 63.6% of 44 Clostridium spp., 65.8% of 38 anaerobic nonsporeforming gram-positive bacilli, and 69.1% of 110 anaerobic cocci, with no further testing required. When genus-level identifications were included, 83.9% of the anaerobic gram-negative bacilli, 70.5% of Clostridium spp., 73.7% of the anaerobic nonsporeforming gram-positive bacilli, and 73.6% of the anaerobic cocci were identified. Nineteen isolates (5.6%) produced identifications of good confidence but marginal separation or questionable biotype, in which the correct identification was listed with one or two other possible choices and extra tests were required and suggested. A total of 28 (8.2%) were not identified and 29 isolates (8.5%) were misidentified by the ANI card. Among the commonly isolated clinically significant anaerobes, the ANI card identified 100% of 55 Bacteroides fragilis and 100% of 8 Clostridium perfringens. Use of supplemental tests and expansion of the data base to include additional strains of organisms that are difficult to separate even with conventional methods may improve the accuracy of the ANI card as a method for identification of anaerobic bacteria in the clinical laboratory. PMID:3343321
Rodgers, Melissa; Meisel, Zachary; Wiebe, Douglas; Crits-Christoph, Paul; Rhodes, Karin V
2016-08-01
Retaining participants in longitudinal studies is a unique methodological challenge in many areas of investigation, and specifically for researchers aiming to identify effective interventions for women experiencing intimate partner violence (IPV). Individuals in abusive relationships are often transient and have logistical, confidentiality, and safety concerns that limit future contact. A natural experiment occurred during a large randomized clinical trial enrolling women in abusive relationships who were also heavy drinkers, which allowed for the comparison of two incentive methods to promote longitudinal retention: cash payment versus reloadable wireless bank cards. In all, 600 patients were enrolled in the overall trial, which aimed to incentivize participants using a reloadable bank card system to promote the completion of 11 weekly interactive voice response system (IVRS) phone surveys and 3-, 6-, and 12-month follow-up phone or in person interviews. The first 145 participants were paid with cash as a result of logistical delays in setting up the bank card system. At 12 weeks, participants receiving the bank card incentive completed significantly more IVRS phone surveys, odds ratio (OR) = 2.4, 95% confidence interval (CI) = [0.01, 1.69]. There were no significant differences between the two groups related to satisfaction or safety and/or privacy. The bank card system delivered lower administrative burden for tracking payments for study staff. Based on these and other results, our large medical research university is implementing reloadable bank card as the preferred method of participant incentive payments.
NASA Astrophysics Data System (ADS)
Bayharti; Iswendi, I.; Arifin, M. N.
2018-04-01
The purpose of this research was to produce a chemistry game card as an instructional media in the subject of naming chemical compounds and determine the degree of validity and practicality of instructional media produced. Type of this research was Research and Development (R&D) that produced a product. The development model used was4-D model which comprises four stages incuding: (1) define, (2) design, (3) develop, and (4) disseminate. This research was restricted at the development stage. Chemistry game card developed was validated by seven validators and practicality was tested to class X6 students of SMAN 5 Padang. Instrument of this research is questionnair that consist of validity sheet and practicality sheet. Technique in collection data was done by distributing questionnaire to the validators, chemistry teachers, and students. The data were analyzed by using formula Cohen’s Kappa. Based on data analysis, validity of chemistry game card was0.87 with category highly valid and practicality of chemistry game card was 0.91 with category highly practice.
Filter paper collection of Plasmodium falciparum mRNA for detecting low-density gametocytes
2012-01-01
Background Accurate sampling of sub-microscopic gametocytes is necessary for epidemiological studies to identify the infectious reservoir of Plasmodium falciparum. Detection of gametocyte mRNA achieves sensitive detection, but requires careful handling of samples. Filter papers can be used for collecting RNA samples, but rigorous testing of their capacity to withstand adverse storage conditions has not been fully explored. Methods Three gametocyte dilutions: 10/μL, 1.0/μL and 0.1/μL were spotted onto Whatman™ 903 Protein Saver Cards, FTA Classic Cards and 3MM filter papers that were stored under frozen, cold chain or tropical conditions for up to 13 weeks . RNA was extracted, then detected by quantitative nucleic acid sequence-based amplification (QT-NASBA) and reverse-transcriptase PCR (RT-PCR). Results Successful gametocyte detection was more frequently observed from the Whatman 903 Protein Saver Card compared to the Whatman FTA Classic Card, by both techniques (p < 0.0001). When papers were stored at higher temperatures, a loss in sensitivity was experienced for the FTA Classic Card but not the 903 Protein Saver Card or Whatman 3MM filter paper. The sensitivity of gametocyte detection was decreased when papers were stored at high humidity. Conclusions This study indicates the Whatman 903 Protein Saver Card is better for Pfs25 mRNA sampling compared to the Whatman FTA Classic Card, and that the Whatman 3MM filter paper may prove to be a satisfactory cheaper option for Pfs25 mRNA sampling. When appropriately dried, filter papers provide a useful approach to Pfs25 mRNA sampling, especially in settings where storage in RNA-protecting buffer is not possible. PMID:22873569
Filter paper collection of Plasmodium falciparum mRNA for detecting low-density gametocytes.
Jones, Sophie; Sutherland, Colin J; Hermsen, Cornelus; Arens, Theo; Teelen, Karina; Hallett, Rachel; Corran, Patrick; van der Vegte-Bolmer, Marga; Sauerwein, Robert; Drakeley, Chris J; Bousema, Teun
2012-08-08
Accurate sampling of sub-microscopic gametocytes is necessary for epidemiological studies to identify the infectious reservoir of Plasmodium falciparum. Detection of gametocyte mRNA achieves sensitive detection, but requires careful handling of samples. Filter papers can be used for collecting RNA samples, but rigorous testing of their capacity to withstand adverse storage conditions has not been fully explored. Three gametocyte dilutions: 10/μL, 1.0/μL and 0.1/μL were spotted onto Whatman™ 903 Protein Saver Cards, FTA Classic Cards and 3MM filter papers that were stored under frozen, cold chain or tropical conditions for up to 13 weeks . RNA was extracted, then detected by quantitative nucleic acid sequence-based amplification (QT-NASBA) and reverse-transcriptase PCR (RT-PCR). Successful gametocyte detection was more frequently observed from the Whatman 903 Protein Saver Card compared to the Whatman FTA Classic Card, by both techniques (p<0.0001). When papers were stored at higher temperatures, a loss in sensitivity was experienced for the FTA Classic Card but not the 903 Protein Saver Card or Whatman 3MM filter paper. The sensitivity of gametocyte detection was decreased when papers were stored at high humidity. This study indicates the Whatman 903 Protein Saver Card is better for Pfs25 mRNA sampling compared to the Whatman FTA Classic Card, and that the Whatman 3MM filter paper may prove to be a satisfactory cheaper option for Pfs25 mRNA sampling. When appropriately dried, filter papers provide a useful approach to Pfs25 mRNA sampling, especially in settings where storage in RNA-protecting buffer is not possible.
[Cardiovascular circulation feedback control treatment instrument].
Ge, Yu-zhi; Zhu, Xing-huan; Sheng, Guo-tai; Cao, Ping-liang; Liu, Dong-sheng; Wu, Zhi-ting
2005-07-01
The cardiovascular circulation feedback control treatment instrument (CFCTI) is an automatic feedback control treatment system, which has the function of monitoring, alarming, trouble self-diagnosis and testing on the line in the closed loop. The instrument is designed based on the successful clinical experiences and the data are inputted into the computer in real-time through a pressure sensor and A/D card. User interface window is set up for the doctor's choosing different medicine. The orders are outputted to control the dose of medicine through the transfusion system. The response to medicine is updated continually. CFCTI can avoid the man-made errors and the long interval of sampling. Its reliability and accuracy in rescuing the critical patients are much higher than the traditional methods.
[Integrated Development of Full-automatic Fluorescence Analyzer].
Zhang, Mei; Lin, Zhibo; Yuan, Peng; Yao, Zhifeng; Hu, Yueming
2015-10-01
In view of the fact that medical inspection equipment sold in the domestic market is mainly imported from abroad and very expensive, we developed a full-automatic fluorescence analyzer in our center, presented in this paper. The present paper introduces the hardware architecture design of FPGA/DSP motion controlling card+PC+ STM32 embedded micro processing unit, software system based on C# multi thread, design and implementation of double-unit communication in detail. By simplifying the hardware structure, selecting hardware legitimately and adopting control system software to object-oriented technology, we have improved the precision and velocity of the control system significantly. Finally, the performance test showed that the control system could meet the needs of automated fluorescence analyzer on the functionality, performance and cost.
Klein, Angela S; Skinner, Jeremy B; Hawley, Kristin M
2013-12-01
The current study examined two condensed adaptations of dialectical behavior therapy (DBT) for binge eating. Women with full- or sub-threshold variants of either binge eating disorder or bulimia nervosa were randomly assigned to individually supported self-monitoring using adapted DBT diary cards (DC) or group-based DBT, each 15 sessions over 16 weeks. DC sessions focused on problem-solving diary card completion issues, praising diary card completion, and supporting nonjudgmental awareness of eating-related habits and urges, but not formally teaching DBT skills. Group-based DBT included eating mindfulness, progressing through graded exposure; mindfulness, emotion regulation, and distress tolerance skills; and coaching calls between sessions. Both treatments evidenced large and significant improvements in binge eating, bulimic symptoms, and interoceptive awareness. For group-based DBT, ineffectiveness, drive for thinness, body dissatisfaction, and perfectionism also decreased significantly, with medium to large effect sizes. For DC, results were not significant but large in effect size for body dissatisfaction and medium in effect size for ineffectiveness and drive for thinness. Retention for both treatments was higher than recent trends for eating disorder treatment in fee-for-service practice and for similar clinic settings, but favored DC, with the greater attrition of group-based DBT primarily attributed to its more intensive and time-consuming nature, and dropout overall associated with less pretreatment impairment and greater interoceptive awareness. This preliminary investigation suggests that with both abbreviated DBT-based treatments, substantial improvement in core binge eating symptoms is possible, enhancing potential avenues for implementation beyond more time-intensive DBT.
Friedline, Terri; West, Stacia; Rosell, Nehemiah; Serido, Joyce; Shim, Soyeon
2017-03-01
This study examines the extent of emergent, outstanding credit card debt among young adult college students and investigates whether any associations existed between this credit card debt and the characteristics of the communities in which these students grew up or lived. Using data (N = 748) from a longitudinal survey and merging community characteristics measured at the zip code level, we confirmed that a community's unemployment rate, average total debt, average credit score, and number of bank branch offices were associated with a young adult college student's acquisition and accumulation of credit card debt. For example, a community's higher unemployment rate and lower number of bank branches were associated with a young adult college student's greater accumulated debt. Community characteristics had the strongest associations with credit card debt, especially after controlling for individual characteristics (i.e., a young adult college student's race and financial independence) and familial characteristics (i.e., their parents' income and parents' discussions of financial matters while growing up at home). The findings may help to understand the unique roles that communities play in shaping children and young adults' financial capability, and how communities can be better capacitated to support the financial goals of their residents. © Society for Community Research and Action 2017.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schambach, Joachim; Rossewij, M. J.; Sielewicz, K. M.
The ALICE Collaboration is preparing a major detector upgrade for the LHC Run 3, which includes the construction of a new silicon pixel based Inner Tracking System (ITS). The ITS readout system consists of 192 readout boards to control the sensors and their power system, receive triggers, and deliver sensor data to the DAQ. To prototype various aspects of this readout system, an FPGA based carrier board and an associated FMC daughter card containing the CERN Gigabit Transceiver (GBT) chipset have been developed. Furthermore, this contribution describes laboratory and radiation testing results with this prototype board set.
Schambach, Joachim; Rossewij, M. J.; Sielewicz, K. M.; ...
2016-12-28
The ALICE Collaboration is preparing a major detector upgrade for the LHC Run 3, which includes the construction of a new silicon pixel based Inner Tracking System (ITS). The ITS readout system consists of 192 readout boards to control the sensors and their power system, receive triggers, and deliver sensor data to the DAQ. To prototype various aspects of this readout system, an FPGA based carrier board and an associated FMC daughter card containing the CERN Gigabit Transceiver (GBT) chipset have been developed. Furthermore, this contribution describes laboratory and radiation testing results with this prototype board set.
A microcomputer-based whole-body counter for personnel routine monitoring.
Chou, H P; Tsai, T M; Lan, C Y
1993-05-01
The paper describes a cost-effective NaI(Tl) whole-body counter developed for routine examinations of worker intakes at an isotope production facility. Signal processing, data analysis and system operation are microcomputer-controlled for minimum human interactions. The pulse height analyzer is developed as an microcomputer add-on card for easy manipulation. The scheme for radionuclide analysis is aimed for fast running according to a knowledge base established from background samples and phantom experiments in conjunction with a multivariate regression analysis. Long-term stability and calibration with standards and in vivo measurements are reported.
NASA Astrophysics Data System (ADS)
Schambach, J.; Rossewij, M. J.; Sielewicz, K. M.; Aglieri Rinella, G.; Bonora, M.; Ferencei, J.; Giubilato, P.; Vanat, T.
2016-12-01
The ALICE Collaboration is preparing a major detector upgrade for the LHC Run 3, which includes the construction of a new silicon pixel based Inner Tracking System (ITS). The ITS readout system consists of 192 readout boards to control the sensors and their power system, receive triggers, and deliver sensor data to the DAQ. To prototype various aspects of this readout system, an FPGA based carrier board and an associated FMC daughter card containing the CERN Gigabit Transceiver (GBT) chipset have been developed. This contribution describes laboratory and radiation testing results with this prototype board set.
The Ruggedized STD Bus Microcomputer - A low cost computer suitable for Space Shuttle experiments
NASA Technical Reports Server (NTRS)
Budney, T. J.; Stone, R. W.
1982-01-01
Previous space flight computers have been costly in terms of both hardware and software. The Ruggedized STD Bus Microcomputer is based on the commercial Mostek/Pro-Log STD Bus. Ruggedized PC cards can be based on commercial cards from more than 60 manufacturers, reducing hardware cost and design time. Software costs are minimized by using standard 8-bit microprocessors and by debugging code using commercial versions of the ruggedized flight boards while the flight hardware is being fabricated.
Tian, Maoyi; Ajay, Vamadevan S; Dunzhu, Danzeng; Hameed, Safraj S; Li, Xian; Liu, Zhong; Li, Cong; Chen, Hao; Cho, KaWing; Li, Ruilai; Zhao, Xingshan; Jindal, Devraj; Rawal, Ishita; Ali, Mohammed K; Peterson, Eric D; Ji, Jiachao; Amarchand, Ritvik; Krishnan, Anand; Tandon, Nikhil; Xu, Li-Qun; Wu, Yangfeng; Prabhakaran, Dorairaj; Yan, Lijing L
2015-09-01
In rural areas in China and India, the cardiovascular disease burden is high but economic and healthcare resources are limited. This study (the Simplified Cardiovascular Management Study [SimCard]) aims to develop and evaluate a simplified cardiovascular management program delivered by community health workers with the aid of a smartphone-based electronic decision support system. The SimCard study was a yearlong cluster-randomized, controlled trial conducted in 47 villages (27 in China and 20 in India). Recruited for the study were 2086 individuals with high cardiovascular risk (aged ≥40 years with self-reported history of coronary heart disease, stroke, diabetes mellitus, and/or measured systolic blood pressure ≥160 mm Hg). Participants in the intervention villages were managed by community health workers through an Android-powered app on a monthly basis focusing on 2 medication use and 2 lifestyle modifications. In comparison with the control group, the intervention group had a 25.5% (P<0.001) higher net increase in the primary outcome of the proportion of patient-reported antihypertensive medication use pre- and post-intervention. There were also significant differences in certain secondary outcomes: aspirin use (net difference: 17.1%; P<0.001) and systolic blood pressure (-2.7 mm Hg; P=0.04). However, no significant changes were observed in the lifestyle factors. The intervention was culturally tailored, and country-specific results revealed important differences between the regions. The results indicate that the simplified cardiovascular management program improved quality of primary care and clinical outcomes in resource-poor settings in China and India. Larger trials in more places are needed to ascertain the potential impacts on mortality and morbidity outcomes. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01503814. © 2015 American Heart Association, Inc.
Sborgi, Lorenzo; Ravotti, Francesco; Dandey, Venkata P.; Dick, Mathias S.; Mazur, Adam; Reckel, Sina; Chami, Mohamed; Scherer, Sebastian; Huber, Matthias; Böckmann, Anja; Egelman, Edward H.; Stahlberg, Henning; Broz, Petr; Meier, Beat H.; Hiller, Sebastian
2015-01-01
Inflammasomes are multiprotein complexes that control the innate immune response by activating caspase-1, thus promoting the secretion of cytokines in response to invading pathogens and endogenous triggers. Assembly of inflammasomes is induced by activation of a receptor protein. Many inflammasome receptors require the adapter protein ASC [apoptosis-associated speck-like protein containing a caspase-recruitment domain (CARD)], which consists of two domains, the N-terminal pyrin domain (PYD) and the C-terminal CARD. Upon activation, ASC forms large oligomeric filaments, which facilitate procaspase-1 recruitment. Here, we characterize the structure and filament formation of mouse ASC in vitro at atomic resolution. Information from cryo-electron microscopy and solid-state NMR spectroscopy is combined in a single structure calculation to obtain the atomic-resolution structure of the ASC filament. Perturbations of NMR resonances upon filament formation monitor the specific binding interfaces of ASC-PYD association. Importantly, NMR experiments show the rigidity of the PYD forming the core of the filament as well as the high mobility of the CARD relative to this core. The findings are validated by structure-based mutagenesis experiments in cultured macrophages. The 3D structure of the mouse ASC-PYD filament is highly similar to the recently determined human ASC-PYD filament, suggesting evolutionary conservation of ASC-dependent inflammasome mechanisms. PMID:26464513
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fachechi, Alessio; Mainetti, Luca; Palano, Laura
The continuously rising demand for electricity has prompted governments and industries to research more effective energy management systems. The Internet of Things paradigm is a valuable add-on for controlling and managing the energy appliances such as Plug-in Electrical Vehicles (PEV) charging stations. In this paper, we present a Demand Response implementation for PEV charging stations able to use Wireless Sensor Network technologies based on the Constrained Application Protocol (CoAP). We developed a self-service kiosk system by which the user can autonomously swipe his/her credit card and choose the charging station to enable. When a user plugs his/her vehicle to themore » station, s/he subscribes his availability to share a portion of its energy. When the grid requests a contribution from the PEVs, the kiosk sends a CoAP message to the available stations and the energy flow is inverted (Vehicle-to-Grid). At the end of the charging process, the user's credit card gets charged with a discounted bill.« less
High speed multiphoton imaging
NASA Astrophysics Data System (ADS)
Li, Yongxiao; Brustle, Anne; Gautam, Vini; Cockburn, Ian; Gillespie, Cathy; Gaus, Katharina; Lee, Woei Ming
2016-12-01
Intravital multiphoton microscopy has emerged as a powerful technique to visualize cellular processes in-vivo. Real time processes revealed through live imaging provided many opportunities to capture cellular activities in living animals. The typical parameters that determine the performance of multiphoton microscopy are speed, field of view, 3D imaging and imaging depth; many of these are important to achieving data from in-vivo. Here, we provide a full exposition of the flexible polygon mirror based high speed laser scanning multiphoton imaging system, PCI-6110 card (National Instruments) and high speed analog frame grabber card (Matrox Solios eA/XA), which allows for rapid adjustments between frame rates i.e. 5 Hz to 50 Hz with 512 × 512 pixels. Furthermore, a motion correction algorithm is also used to mitigate motion artifacts. A customized control software called Pscan 1.0 is developed for the system. This is then followed by calibration of the imaging performance of the system and a series of quantitative in-vitro and in-vivo imaging in neuronal tissues and mice.
Study of the NASTRAN input/output systems
NASA Technical Reports Server (NTRS)
Brown, W. K.; Schoellmann, W. F.
1977-01-01
The basic characteristics of the NASTRAN level 16 I/O subsystem are presented with particular reference to blocking/deblocking aspects, I/O methods used on the IBM, CDC, and UNIVAC machines, definition of basic NASTRAN I/O control tables, and portability of parts of the I/O subsystem to other programs outside the NASTRAN environment are included. An explanation of the IBM primary, secondary, and tertiary files defined by the data definition (DD) cards in the NASTRAN JCL procedure. The explanation is intended to enlighten users as to the purpose of these DD cards, how they relate to one another, and why there are no similar type definition cards required on the CDC and UNIVAC versions. Enhancements designed to increase overall efficiency and decrease core requirements are also recommended.
NASA Astrophysics Data System (ADS)
Thiebaud, P.; Cross, D. C.
1980-07-01
A new solid-state radar switchboard equipped with 16 input ports which will output data to 16 displays is presented. Each of the ports will handle a single two-dimensional radar input, or three ports will accommodate a three-dimensional radar input. A video switch card of the switchboard is used to switch all signals, with the exception of the IFF-mode-control lines. Each card accepts inputs from up to 16 sources and can pass a signal with bandwidth greater than 20 MHz to the display assigned to that card. The synchro amplifier of current systems has been eliminated and in the new design each PPI receives radar data via a single coaxial cable. This significant reduction in cabling is achieved by adding a serial-to-parallel interface and a digital-to-synchro converter located at the PPI.
An mHealth Framework to Improve Birth Outcomes in Benue State, Nigeria: A Study Protocol.
Ezeanolue, Echezona Edozie; Gbadamosi, Semiu Olatunde; Olawepo, John Olajide; Iwelunmor, Juliet; Sarpong, Daniel; Eze, Chuka; Ogidi, Amaka; Patel, Dina; Onoka, Chima
2017-05-26
The unprecedented coverage of mobile technology across the globe has led to an increase in the use of mobile health apps and related strategies to make health information available at the point of care. These strategies have the potential to improve birth outcomes, but are limited by the availability of Internet services, especially in resource-limited settings such as Nigeria. Our primary objective is to determine the feasibility of developing an integrated mobile health platform that is able to collect data from community-based programs, embed collected data into a smart card, and read the smart card using a mobile phone-based app without the need for Internet access. Our secondary objectives are to determine (1) the acceptability of the smart card among pregnant women and (2) the usability of the smart card by pregnant women and health facilities in rural Nigeria. We will leverage existing technology to develop a platform that integrates a database, smart card technology, and a mobile phone-based app to read the smart cards. We will recruit 300 pregnant women with one of the three conditions-HIV, hepatitis B virus infection, and sickle cell trait or disease-and four health facilities in their community. We will use Glasgow's Reach, Effectiveness, Adoption, Implementation, and Maintenance framework as a guide to assess the implementation, acceptability, and usability of the mHealth platform. We have recruited four health facilities and 300 pregnant women with at least one of the eligible conditions. Over the course of 3 months, we will complete the development of the mobile health platform and each participant will be offered a smart card; staff in each health facility will receive training on the use of the mobile health platform. Findings from this study could offer a new approach to making health data from pregnant women available at the point of delivery without the need for an Internet connection. This would allow clinicians to implement evidence-based interventions in real time to improve health outcomes. ClinicalTrials.gov NCT03027258; https://clinicaltrials.gov/ct2/show/NCT03027258 (Archived by WebCite at http://www.webcitation.org/6owR2D0kE). ©Echezona Edozie Ezeanolue, Semiu Olatunde Gbadamosi, John Olajide Olawepo, Juliet Iwelunmor, Daniel Sarpong, Chuka Eze, Amaka Ogidi, Dina Patel, Chima Onoka. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 26.05.2017.
Computer program CDCID: an automated quality control program using CDC update
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singer, G.L.; Aguilar, F.
1984-04-01
A computer program, CDCID, has been developed in coordination with a quality control program to provide a highly automated method of documenting changes to computer codes at EG and G Idaho, Inc. The method uses the standard CDC UPDATE program in such a manner that updates and their associated documentation are easily made and retrieved in various formats. The method allows each card image of a source program to point to the document which describes it, who created the card, and when it was created. The method described is applicable to the quality control of computer programs in general. Themore » computer program described is executable only on CDC computing systems, but the program could be modified and applied to any computing system with an adequate updating program.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martinez, B.; Pomeroy, G.
1989-12-02
The Security Alarm System is a data acquisition and control system which collects data from intrusion sensors and displays the information in a real-time environment for operators. The Access Control System monitors and controls the movement of personnel with the use of card readers and biometrics hand readers.
Home-based child vaccination records--a reflection on form.
Brown, David W; Gacic-Dobo, Marta; Young, Stacy L
2014-04-01
Home-based child vaccination records play an important role in documenting immunization services received by children. We report some of the results of a review of home-based vaccination records from 55 countries. In doing so, we categorize records into three groups (vaccination only cards, vaccination plus cards, child health books) and describe differences in characteristics related to the quality of data recorded on immunization. Moreover, we highlight areas of potential concern and areas in need of further research and investigation to improve our understanding of the home-based vaccination record form related to improved data quality from immunization service delivery. Copyright © 2014. Published by Elsevier Ltd.
Aubin, M.; Vézina, L.; Maziade, J.; Robitaille, N. M.
1994-01-01
OBJECTIVE: To evaluate the effectiveness of a program to improve hypertension control practices in primary care. DESIGN: Retrospective quasi-experimental study. SETTING: Three hospital-based family medicine centres (FMCs) PARTICIPANTS: Two study groups of 100 randomly-selected adult patients each, who visited the study FMC before implementation of the hypertension program (from April 1, 1983 to March 31, 1984) or afterward (from April 1, 1986 to March 31, 1987). These patients were compared to patients from control FMCs A and B seen during the same time frames (100 patients before and after at FMC A and 60 at FMC B). INTERVENTIONS: 1) Educational sessions for physicians to standardize knowledge of the recommendations of the Canadian Hypertension Society on hypertension treatment and 2) specific operational incentives to improve hypertension control, including a reference guide placed in each physician's office, a specific hypertension follow-up form placed with each patient's chart, a recall card file, and hypertension information handouts. MAIN OUTCOME MEASURE: Blood pressure measurements recorded in patient charts. Hypertension control is determined from the Canadian Hypertension Society recommendations. RESULTS: The hypertension control rate was 52% in the study group before program implementation and 34.3% afterward (p = 0.01); the corresponding rates in the two control groups moved from 47.4% to 59.8% (p > 0.05) in Group A and from 40.7% to 39.3% (p > 0.05) in Group B. Patients listed in the recall card file were not controlled more frequently (33.3%) than those not listed (35.3%). CONCLUSION: This intervention did not improve physician practice regarding hypertension control. Clinicians did not follow the protocol as recommended. Physicians must be convinced that a change in their practice is needed before any specific strategies are introduced to support the change. Different suggestions and alternatives related to hypertension management are discussed. PMID:7950469
The Memory Stack: New Technologies Harness Talking for Writing.
ERIC Educational Resources Information Center
Gannon, Maureen T.
In this paper, an elementary school teacher describes her experiences with the Memory Stack--a HyperCard based tool that can accommodate a voice recording, a graphic image, and a written text on the same card--which she designed to help her second and third grade students integrate their oral language fluency into the process of learning how to…
ERIC Educational Resources Information Center
Su, TzuFen; Cheng, Meng-Tzu; Lin, Shu-Hua
2014-01-01
This study was conducted in an attempt to investigate the effectiveness of an educational card game we developed for learning human immunology. Two semesters of evaluation were included to examine the impact of the game on students' understanding and perceptions of the game-based instruction. Ninety-nine senior high school students (11th graders)…
ERIC Educational Resources Information Center
Vujnovic, Rebecca Kate
2010-01-01
Given the deficits associated with ADHD and the significant prevalence, it is important to explore evidence based treatments for ADHD in the classroom and the efficacy with which the classroom teachers implement such interventions. The current investigation is a secondary analysis to investigate the integrity of a Daily Report Card (DRC)…
The Dynamics of Development on the Dimensional Change Card Sorting Task
ERIC Educational Resources Information Center
van Bers, Bianca M. C. W.; Visser, Ingmar; van Schijndel, Tessa J. P.; Mandell, Dorothy J.; Raijmakers, Maartje E. J.
2011-01-01
A widely used paradigm to study cognitive flexibility in preschoolers is the Dimensional Change Card Sorting (DCCS) task. The developmental dynamics of DCCS performance was studied in a cross-sectional design (N = 93, 3 to 5 years of age) using a computerized version of the standard DCCS task. A model-based analysis of the data showed that…
Operating a Geiger-Muller Tube Using a PC Sound Card
ERIC Educational Resources Information Center
Azooz, A. A.
2009-01-01
In this paper, a simple MATLAB-based PC program that enables the computer to function as a replacement for the electronic scalar-counter system associated with a Geiger-Muller (GM) tube is described. The program utilizes the ability of MATLAB to acquire data directly from the computer sound card. The signal from the GM tube is applied to the…
ERIC Educational Resources Information Center
Head, Denise; Kennedy, Kristen M.; Rodrigue, Karen M.; Raz, Naftali
2009-01-01
Aging effects on the Wisconsin Card Sorting Test (WCST) are fairly well established but the mechanisms of the decline are not clearly understood. In this study, we examined the cognitive and neural mechanisms mediating age-related increases in perseveration on the WCST. MRI-based volumetry and measures of selected executive functions in…
It Doesn't Take a Rocket Scientist. It Just Takes You! Kansas Children's Report Card, 2001.
ERIC Educational Resources Information Center
Kansas Action for Children, Inc., Topeka.
This document uses a school report card format to present information on the current well-being of Kansas' children. "Grades" are based on 17 indicators of well-being in five areas: (1) safety and security (violent crime, child abuse and neglect, and childhood poverty); (2) health (early prenatal care, low birthweight, infant mortality,…
NASA Astrophysics Data System (ADS)
Ratnadewi; Pramono Adhie, Roy; Hutama, Yonatan; Saleh Ahmar, A.; Setiawan, M. I.
2018-01-01
Cryptography is a method used to create secure communication by manipulating sent messages during the communication occurred so only intended party that can know the content of that messages. Some of the most commonly used cryptography methods to protect sent messages, especially in the form of text, are DES and 3DES cryptography method. This research will explain the DES and 3DES cryptography method and its use for stored data security in smart cards that working in the NFC-based communication system. Several things that will be explained in this research is the ways of working of DES and 3DES cryptography method in doing the protection process of a data and software engineering through the creation of application using C++ programming language to realize and test the performance of DES and 3DES cryptography method in encrypted data writing process to smart cards and decrypted data reading process from smart cards. The execution time of the entering and the reading process data using a smart card DES cryptography method is faster than using 3DES cryptography.
Health communication cards as a tool for behaviour change.
Matteson, Carrie L; Merth, Thomas D N; Finegood, Diane T
2014-01-01
Individuals seeking healthcare treatment in the context of obesity often experience difficulty engaging in discussions around their health and face challenges finding consensus with practitioners on care plans that best suit their lives. The complex set of biological, social, and environmental variables that have contributed to the higher prevalence of obesity are well illustrated in the foresight obesity system map. Effectively understanding and addressing key variables for each individual has proven to be difficult, with clinicians facing barriers and limited resources to help address patients' unique needs. However, productive discussions inspired by patient centered care may be particularly effective in promoting behaviour change. Tools based on systems science that facilitate patient centered care and help identify behaviour change priorities have not been developed to help treat adult obesity. This project created and pilot tested a card based clinical communication tool designed to help facilitate conversations with individuals engaged in health behaviour change. The health communication cards were designed to help direct conversation between patients and healthcare providers toward issues relevant to the individual. Use of the cards to facilitate patient driven conversations in clinical care may help to streamline conversations, set realistic care plan goals, and improve long term rates of compliance.
NASA Technical Reports Server (NTRS)
Wennersten, Miriam; Banes, Vince; Boegner, Greg; Clagnett, Charles; Dougherty, Lamar; Edwards, Bernard; Roman, Joe; Bauer, Frank H. (Technical Monitor)
2001-01-01
NASA Goddard Space Flight Center has built an open architecture, 24 channel spaceflight Global Positioning System (GPS) receiver. The compact PCI PiVoT GPS receiver card is based on the Mitel/GEC Plessey Builder 2 board. PiVoT uses two Plessey 2021 correlators to allow tracking of up to 24 separate GPS SV's on unique channels. Its four front ends can support four independent antennas, making it a useful card for hosting GPS attitude determination algorithms. It has been built using space quality, radiation tolerant parts. The PiVoT card works at a lower signal to noise ratio than the original Builder 2 board. It also hosts an improved clock oscillator. The PiVoT software is based on the original Piessey Builder 2 software ported to the Linux operating system. The software is posix compliant and can be easily converted to other posix operating systems. The software is open source to anyone with a licensing agreement with Plessey. Additional tasks can be added to the software to support GPS science experiments or attitude determination algorithms. The next generation PiVoT receiver will be a single radiation hardened compact PCI card containing the microprocessor and the GPS receiver optimized for use above the GPS constellation.
Development of the biology card sorting task to measure conceptual expertise in biology.
Smith, Julia I; Combs, Elijah D; Nagami, Paul H; Alto, Valerie M; Goh, Henry G; Gourdet, Muryam A A; Hough, Christina M; Nickell, Ashley E; Peer, Adrian G; Coley, John D; Tanner, Kimberly D
2013-01-01
There are widespread aspirations to focus undergraduate biology education on teaching students to think conceptually like biologists; however, there is a dearth of assessment tools designed to measure progress from novice to expert biological conceptual thinking. We present the development of a novel assessment tool, the Biology Card Sorting Task, designed to probe how individuals organize their conceptual knowledge of biology. While modeled on tasks from cognitive psychology, this task is unique in its design to test two hypothesized conceptual frameworks for the organization of biological knowledge: 1) a surface feature organization focused on organism type and 2) a deep feature organization focused on fundamental biological concepts. In this initial investigation of the Biology Card Sorting Task, each of six analytical measures showed statistically significant differences when used to compare the card sorting results of putative biological experts (biology faculty) and novices (non-biology major undergraduates). Consistently, biology faculty appeared to sort based on hypothesized deep features, while non-biology majors appeared to sort based on either surface features or nonhypothesized organizational frameworks. Results suggest that this novel task is robust in distinguishing populations of biology experts and biology novices and may be an adaptable tool for tracking emerging biology conceptual expertise.
Design on the x-ray oral digital image display card
NASA Astrophysics Data System (ADS)
Wang, Liping; Gu, Guohua; Chen, Qian
2009-10-01
According to the main characteristics of X-ray imaging, the X-ray display card is successfully designed and debugged using the basic principle of correlated double sampling (CDS) and combined with embedded computer technology. CCD sensor drive circuit and the corresponding procedures have been designed. Filtering and sampling hold circuit have been designed. The data exchange with PC104 bus has been implemented. Using complex programmable logic device as a device to provide gating and timing logic, the functions which counting, reading CPU control instructions, corresponding exposure and controlling sample-and-hold have been completed. According to the image effect and noise analysis, the circuit components have been adjusted. And high-quality images have been obtained.
Mechanization of Cataloging Procedures *
Kilgour, Frederick G.
1965-01-01
The Columbia-Harvard-Yale Medical Libraries Computerization Project has put into operation its mechanized procedure for the production of catalog cards. Cards produced are in final form ready to be filed into a card catalog. Catalogers prepare copy on a worksheet from which punched cards are punched. An IBM 1401 computer processes the decklets of punched cards on magnetic tape to produce the expanded decklets of punched cards needed to print the various packs of catalog cards required to go into different catalogs. Next, the computer punches the expanded decklets of cards to operate an 870 Document Writer, which types out the catalog cards in final form. Cost of cards ready to file is 12.5 cents per card. Images PMID:14271110
Evaluation of an online partner notification program.
Rietmeijer, Cornelis A; Westergaard, Benton; Mickiewicz, Theresa A; Richardson, Doug; Ling, Sarah; Sapp, Terri; Jordan, Rebecca; Wilmoth, Ralph; Kachur, Rachel; McFarlane, Mary
2011-05-01
Internet-based programs for sexually transmitted infections (STI)/HIV partner notification have generated considerable interest as public health interventions; yet data are lacking to support widespread dissemination. We report on a clinic-based and web-based evaluation of the Colorado inSPOT online partner notification program. Clinic-based surveys were conducted at a large urban STI clinic before and after the implementation of feasible clinic interventions as well as nonclinic campaigns to promote the use of inSPOT Colorado. Questions assessed recognition and use of the site. Website statistics were provided by the inSPOT service, including the number of site hits, e-cards sent, and specific STI exposures identified on the card. Recognition and use of the service among STI clinic patients remained low (<6%) despite the interventions. Site statistics demonstrated an immediate but quickly diminishing response after placement of a banner ad on a popular gay website. Newspaper advertisements and radio public service announcements showed small increases in website use. Analysis of STIs specified on the e-cards, showed scabies and pediculosis as the most-identified STIs, accounting for nearly 30% of all e-cards sent. Clinic survey data indicated that when respondents were faced with the hypothetical situation of being diagnosed with an STI, more than 90% would notify partners in person; only 5% would use e-mail or the Internet. Our data did not support the effectiveness of the inSPOT intervention among a predominantly heterosexual population in a large urban STI clinic.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hubin, Elizabeth A.; Fay, Allison; Xu, Catherine
RbpA and CarD are essential transcription regulators in mycobacteria. Mechanistic analyses of promoter open complex (RPo) formation establish that RbpA and CarD cooperatively stimulate formation of an intermediate (RP2) leading to RPo; formation of RP2 is likely a bottleneck step at the majority of mycobacterial promoters. Once RPo forms, CarD also disfavors its isomerization back to RP2. We determined a 2.76 Å-resolution crystal structure of a mycobacterial transcription initiation complex (TIC) with RbpA as well as a CarD/RbpA/TIC model. Both CarD and RbpA bind near the upstream edge of the -10 element where they likely facilitate DNA bending and impedemore » transcription bubble collapse. In vivo studies demonstrate the essential role of RbpA, show the effects of RbpA truncations on transcription and cell physiology, and indicate additional functions for RbpA not evident in vitro. This work provides a framework to understand the control of mycobacterial transcription by RbpA and CarD.« less
LabVIEW Interface for PCI-SpaceWire Interface Card
NASA Technical Reports Server (NTRS)
Lux, James; Loya, Frank; Bachmann, Alex
2005-01-01
This software provides a LabView interface to the NT drivers for the PCISpaceWire card, which is a peripheral component interface (PCI) bus interface that conforms to the IEEE-1355/ SpaceWire standard. As SpaceWire grows in popularity, the ability to use SpaceWire links within LabVIEW will be important to electronic ground support equipment vendors. In addition, there is a need for a high-level LabVIEW interface to the low-level device- driver software supplied with the card. The LabVIEW virtual instrument (VI) provides graphical interfaces to support all (1) SpaceWire link functions, including message handling and routing; (2) monitoring as a passive tap using specialized hardware; and (3) low-level access to satellite mission-control subsystem functions. The software is supplied in a zip file that contains LabVIEW VI files, which provide various functions of the PCI-SpaceWire card, as well as higher-link-level functions. The VIs are suitably named according to the matching function names in the driver manual. A number of test programs also are provided to exercise various functions.
Reconfigurable multiport EPON repeater
NASA Astrophysics Data System (ADS)
Oishi, Masayuki; Inohara, Ryo; Agata, Akira; Horiuchi, Yukio
2009-11-01
An extended reach EPON repeater is one of the solutions to effectively expand FTTH service areas. In this paper, we propose a reconfigurable multi-port EPON repeater for effective accommodation of multiple ODNs with a single OLT line card. The proposed repeater, which has multi-ports in both OLT and ODN sides, consists of TRs, BTRs with the CDR function and a reconfigurable electrical matrix switch, can accommodate multiple ODNs to a single OLT line card by controlling the connection of the matrix switch. Although conventional EPON repeaters require full OLT line cards to accommodate subscribers from the initial installation stage, the proposed repeater can dramatically reduce the number of required line cards especially when the number of subscribers is less than a half of the maximum registerable users per OLT. Numerical calculation results show that the extended reach EPON system with the proposed EPON repeater can save 17.5% of the initial installation cost compared with a conventional repeater, and can be less expensive than conventional systems up to the maximum subscribers especially when the percentage of ODNs in lightly-populated areas is higher.
Role of two insect growth regulators in integrated pest management of citrus scales.
Grafton-Cardwell, E E; Lee, J E; Stewart, J R; Olsen, K D
2006-06-01
Portions of two commercial citrus orchards were treated for two consecutive years with buprofezin or three consecutive years with pyriproxyfen in a replicated plot design to determine the long-term impact of these insect growth regulators (IGRs) on the San Joaquin Valley California integrated pest management program. Pyriproxyfen reduced the target pest, California red scale, Aonidiella aurantii Maskell, to nondetectable levels on leaf samples approximately 4 mo after treatment. Pyriproxyfen treatments reduced the California red scale parasitoid Aphytis melinus DeBach to a greater extent than the parasitoid Comperiella bifasciata Howard collected on sticky cards. Treatments of lemons Citrus limon (L.) Burm. f. infested with scale parasitized by A. melinus showed only 33% direct mortality of the parasitoid, suggesting the population reduction observed on sticky cards was due to low host density. Three years of pyriproxyfen treatments did not maintain citricola scale, Coccus pseudomagnoliarum (Kuwana), below the treatment threshold and cottony cushion scale, Icerya purchasi Maskell, was slowly but incompletely controlled. Buprofezin reduced California red scale to very low but detectable levels approximately 5 mo after treatment. Buprofezin treatments resulted in similar levels of reduction of the two parasitoids A. melinus and C. bifasciata collected on sticky cards. Treatments of lemons infested with scale parasitized by A. melinus showed only 7% mortality of the parasitoids, suggesting the population reduction observed on sticky cards was due to low host density. Citricola scale was not present in this orchard, and cottony cushion scale was slowly and incompletely controlled by buprofezin. These field plots demonstrated that IGRs can act as organophosphate insecticide replacements for California red scale control; however, their narrower spectrum of activity and disruption of coccinellid beetles can allow other scale species to attain primary pest status.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Avramova, Maria; Blyth, Taylor S.; Salko, Robert K.
This document describes how to make a CTF input deck. A CTF input deck is organized into Card Groups and Cards. A Card Group is a collection of Cards. A Card is defined as a line of input. Each Card may contain multiple data. A Card is terminated by making a new line.
Maw, Min Thein; Yamaguchi, Tsuyoshi; Kasanga, Christopher J; Terasaki, Kaori; Fukushi, Hideto
2006-12-01
A practical sampling method for bursal tissue using ordinary paper for molecular diagnosis of infectious bursal disease (IBD) was established. IBD virus-infected bursa was directly smeared on chromatography paper, filter paper, or stationery copy paper and was then fixed with absolute ethanol, Tris-HCl-saturated phenol, or phenol:chloroform:isoamyl alcohol (25:24:1). Flinders Technology Associates (FTA) card, which is designed for the collection of biological samples for molecular detection, was also used. After storage at 37 C for up to 30 days, total RNA directly extracted from the tissue fixed on the papers and FTA card were subjected to reverse transcriptase-polymerase chain reaction (RT-PCR) for detection of IBD virus (IBDV) RNA. In addition, the ability of each chemical used in the fixation and the FTA card to inactivate IBDV was evaluated. Regardless of the paper quality, storage period, and fixation method, IBDV RNA was consistently detected in all of the samples. IBDV in the bursal tissue was inactivated with phenol but not with ethanol or the unknown chemicals in FTA card. These results show that ordinary papers sustain the viral RNA, as does FTA card, but phenol fixation is superior to FTA card in inactivating IBDV. The new sampling method using ordinary paper with phenol fixation is safe, inexpensive, simple, and easy, and is thus suitable for conducting a global survey of IBD even where laboratory resources are limited. This practical method should contribute to the control of IBD worldwide.
Hunter, Ruth F; Brennan, Sarah F; Tang, Jianjun; Smith, Oliver J; Murray, Jennifer; Tully, Mark A; Patterson, Chris; Longo, Alberto; Hutchinson, George; Prior, Lindsay; French, David P; Adams, Jean; McIntosh, Emma; Kee, Frank
2016-07-22
Increasing physical activity in the workplace can provide employee physical and mental health benefits, and employer economic benefits through reduced absenteeism and increased productivity. The workplace is an opportune setting to encourage habitual activity. However, there is limited evidence on effective behaviour change interventions that lead to maintained physical activity. This study aims to address this gap and help build the necessary evidence base for effective, and cost-effective, workplace interventions. This cluster randomised control trial will recruit 776 office-based employees from public sector organisations in Belfast and Lisburn city centres, Northern Ireland. Participants will be randomly allocated by cluster to either the Intervention Group or Control Group (waiting list control). The 6-month intervention consists of rewards (retail vouchers, based on similar principles to high street loyalty cards), feedback and other evidence-based behaviour change techniques. Sensors situated in the vicinity of participating workplaces will promote and monitor minutes of physical activity undertaken by participants. Both groups will complete all outcome measures. The primary outcome is steps per day recorded using a pedometer (Yamax Digiwalker CW-701) for 7 consecutive days at baseline, 6, 12 and 18 months. Secondary outcomes include health, mental wellbeing, quality of life, work absenteeism and presenteeism, and use of healthcare resources. Process measures will assess intervention "dose", website usage, and intervention fidelity. An economic evaluation will be conducted from the National Health Service, employer and retailer perspective using both a cost-utility and cost-effectiveness framework. The inclusion of a discrete choice experiment will further generate values for a cost-benefit analysis. Participant focus groups will explore who the intervention worked for and why, and interviews with retailers will elucidate their views on the sustainability of a public health focused loyalty card scheme. The study is designed to maximise the potential for roll-out in similar settings, by engaging the public sector and business community in designing and delivering the intervention. We have developed a sustainable business model using a 'points' based loyalty platform, whereby local businesses 'sponsor' the incentive (retail vouchers) in return for increased footfall to their business. ISRCTN17975376 (Registered 19/09/2014).
29 CFR 4.123 - Administrative limitations, variances, tolerances, and exemptions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... servicing of cards (including credit cards, debit cards, purchase cards, smart cards, and similar card... military personnel in buying and selling homes (which shall not include actual moving or storage of...
2011-01-01
Background Diagnosis of blood borne infectious diseases relies primarily on the detection of the causative agent in the blood sample. Molecular techniques offer sensitive and specific tools for this although considerable difficulties exist when using these approaches in the field environment. In large scale epidemiological studies, FTA®cards are becoming increasingly popular for the rapid collection and archiving of a large number of samples. However, there are some difficulties in the downstream processing of these cards which is essential for the accurate diagnosis of infection. Here we describe recommendations for the best practice approach for sample processing from FTA®cards for the molecular diagnosis of trypanosomiasis using PCR. Results A comparison of five techniques was made. Detection from directly applied whole blood was less sensitive (35.6%) than whole blood which was subsequently eluted from the cards using Chelex®100 (56.4%). Better apparent sensitivity was achieved when blood was lysed prior to application on the FTA cards (73.3%) although this was not significant. This did not improve with subsequent elution using Chelex®100 (73.3%) and was not significantly different from direct DNA extraction from blood in the field (68.3%). Conclusions Based on these results, the degree of effort required for each of these techniques and the difficulty of DNA extraction under field conditions, we recommend that blood is transferred onto FTA cards whole followed by elution in Chelex®100 as the best approach. PMID:21548975
The prognostic value of kidney transplant center report cards.
Schold, J D; Buccini, L D; Heaphy, E L G; Goldfarb, D A; Sehgal, A R; Fung, J; Poggio, E D; Kattan, M W
2013-07-01
SRTR report cards provide the basis for quality measurement of US transplant centers. There is limited data evaluating the prognostic value of report cards, informing whether they are predictive of prospective patient outcomes. Using national SRTR data, we simulated report cards and calculated standardized mortality ratios (SMR) for kidney transplant centers over five distinct eras. We ranked centers based on SMR and evaluated outcomes for patients transplanted the year following reports. Recipients transplanted at the 50th, 100th and 200th ranked centers had 18% (AHR = 1.18, 1.13-1.22), 38% (AHR = 1.38, 1.28-1.49) and 91% (AHR = 1.91, 1.64-2.21) increased hazard for 1-year mortality relative to recipients at the top-ranked center. Risks were attenuated but remained significant for long-term outcomes. Patients transplanted at centers meeting low-performance criteria in the prior period had 40% (AHR = 1.40, 1.22-1.68) elevated hazard for 1-year mortality in the prospective period. Centers' SMR from the report card was highly predictive (c-statistics > 0.77) for prospective center SMRs and there was significant correlation between centers' SMR from the report card period and the year following (ρ = 0.57, p < 0.001). Although results do not mitigate potential biases of report cards for measuring quality, they do indicate strong prognostic value for future outcomes. Findings also highlight that outcomes are associated with center ranking across a continuum rather than solely at performance margins. © Copyright 2013 The American Society of Transplantation and the American Society of Transplant Surgeons.
Optics derotator servo control system for SONG Telescope
NASA Astrophysics Data System (ADS)
Xu, Jin; Ren, Changzhi; Ye, Yu
2012-09-01
The Stellar Oscillations Network Group (SONG) is an initiative which aims at designing and building a groundbased network of 1m telescopes dedicated to the study of phenomena occurring in the time domain. Chinese standard node of SONG is an Alt-Az Telescope of F/37 with 1m diameter. Optics derotator control system of SONG telescope adopts the development model of "Industrial Computer + UMAC Motion Controller + Servo Motor".1 Industrial computer is the core processing part of the motion control, motion control card(UMAC) is in charge of the details on the motion control, Servo amplifier accepts the control commands from UMAC, and drives the servo motor. The position feedback information comes from the encoder, to form a closed loop control system. This paper describes in detail hardware design and software design for the optics derotator servo control system. In terms of hardware design, the principle, structure, and control algorithm of servo system based on optics derotator are analyzed and explored. In terms of software design, the paper proposes the architecture of the system software based on Object-Oriented Programming.
Su, TzuFen; Lin, Shu-Hua
2014-01-01
This study was conducted in an attempt to investigate the effectiveness of an educational card game we developed for learning human immunology. Two semesters of evaluation were included to examine the impact of the game on students’ understanding and perceptions of the game-based instruction. Ninety-nine senior high school students (11th graders) were recruited for the first evaluation, and the second-semester group consisted of 72 students (also 11th graders). The results obtained indicate that students did learn from the educational card game. Moreover, students who learned from playing the game significantly outperformed their counterparts in terms of their understanding of the processes and connections among different lines of immunological defense (first semester: t = 2.92, p < 0.01; second semester: t = 3.45, p < 0.01) according to the qualitative analysis of an open-ended question. They generally had positive perceptions toward the game-based instruction and its learning efficiency, and they felt the game-based instruction was much more interesting than traditional didactic lectures (first semester: t = 2.79, p < 0.01; second semester: t = 2.41, p < 0.05). This finding is evidence that the educational card game has potential to facilitate students’ learning of how the immune system works. The implications and suggestions for future work are further discussed. PMID:25185233
Lee, Tian-Fu; Chang, I-Pin; Lin, Tsung-Hung; Wang, Ching-Cheng
2013-06-01
The integrated EPR information system supports convenient and rapid e-medicine services. A secure and efficient authentication scheme for the integrated EPR information system provides safeguarding patients' electronic patient records (EPRs) and helps health care workers and medical personnel to rapidly making correct clinical decisions. Recently, Wu et al. proposed an efficient password-based user authentication scheme using smart cards for the integrated EPR information system, and claimed that the proposed scheme could resist various malicious attacks. However, their scheme is still vulnerable to lost smart card and stolen verifier attacks. This investigation discusses these weaknesses and proposes a secure and efficient authentication scheme for the integrated EPR information system as alternative. Compared with related approaches, the proposed scheme not only retains a lower computational cost and does not require verifier tables for storing users' secrets, but also solves the security problems in previous schemes and withstands possible attacks.
Turning a Private Label Bank Card into a Multi-function Campus ID Card.
ERIC Educational Resources Information Center
James, Thomas G.; Norwood, Bill R.
1991-01-01
This article describes the development at Florida State University of the Seminole ACCESS card, which functions simultaneously as a bank automated teller machine card, a student identification card, and a debit card. Explained are the partnership between the university and the bank charge card center, funding system, technologies involved, and…
Lambert, N; Plumb, J; Looise, B; Johnson, I T; Harvey, I; Wheeler, C; Robinson, M; Rolfe, P
2005-08-01
The aim of the study was to test the feasibility of using smart card technology to track the eating behaviours of nearly a thousand children in a school cafeteria. Within a large boys' school a smart card based system was developed that was capable of providing a full electronic audit of all the individual transactions that occurred within the cafeteria. This dataset was interfaced to an electronic version of the McCance and Widdowson composition of foods dataset. The accuracy of the smart card generated data and the influence of portion size and wastage were determined empirically during two 5-day trials. The smart card system created succeeded in generating precise data on the food choices made by hundreds of children over an indefinite time period. The data was expanded to include a full nutrient analysis of all the foods chosen. The accuracy of this information was only constrained by the limitations facing all food composition research, e.g. variations in recipes, portion sizes, cooking practices, etc. Although technically possible to introduce wastage correction factors into the software, thereby providing information upon foods consumed, this was not seen as universally practical. The study demonstrated the power of smart card technology for monitoring food/nutrient choice over limitless time in environments such as school cafeterias. The strengths, limitations and applications of such technology are discussed.
Zhou, P; Chou, J; Olea, R S; Yuan, J; Wagner, G
1999-09-28
Direct recruitment and activation of caspase-9 by Apaf-1 through the homophilic CARD/CARD (Caspase Recruitment Domain) interaction is critical for the activation of caspases downstream of mitochondrial damage in apoptosis. Here we report the solution structure of the Apaf-1 CARD domain and its surface of interaction with caspase-9 CARD. Apaf-1 CARD consists of six tightly packed amphipathic alpha-helices and is topologically similar to the RAIDD CARD, with the exception of a kink observed in the middle of the N-terminal helix. By using chemical shift perturbation data, the homophilic interaction was mapped to the acidic surface of Apaf-1 CARD centered around helices 2 and 3. Interestingly, a significant portion of the chemically perturbed residues are hydrophobic, indicating that in addition to the electrostatic interactions predicted previously, hydrophobic interaction is also an important driving force underlying the CARD/CARD interaction. On the basis of the identified functional residues of Apaf-1 CARD and the surface charge complementarity, we propose a model of CARD/CARD interaction between Apaf-1 and caspase-9.
Yinnon, A M; Wiener-Well, Y; Jerassy, Z; Dor, M; Freund, R; Mazouz, B; Lupyan, T; Shapira, S; Attias, D; Assous, M V; Kopuit, P; Block, C; Raveh, D; Freier-Dror, Y; Moses, A E; Benenson, S
2012-07-01
Two detailed checklists were developed, based on published infection control guidelines, for daily use by infection control practitioners in departments and operating rooms. To assess the impact of the checklists on nosocomial infection rates in three hospitals over the course of one year. The checklists included 20 subheadings (± 150 items). Project nurses conducted rounds in the study (but not control) departments; during each round, the nurses selected 15-20 items for observation, marked the checklists according to appropriateness of observed behaviour and provided on-the-spot corrective education. Rates of adherence to the checklist, antibiotic use, number of obtained and positive cultures, and positive staff hand and patient environment cultures were reported monthly as a report card to relevant personnel and administrators. The rate of nosocomial infections was determined in the first and last months. The baseline nosocomial infection rate was similar in the study and control departments: 37/345 (11%) and 26/270 (10%) respectively. In the last month, the rate in the study department decreased to 16/383 (4%) (P<0.01); in the control it decreased insignificantly to 21/248 (8%) (not significant). No significant trends were detected in the number of obtained cultures, positive cultures, or antibiotic use. Adherence to guidelines ranged from 75% to 94% between the hospitals (P<0.001): the overall rate increased from 80% to 91% (P<0.01). The use of checklists during the conduct of infection control rounds, combined with monthly reports, was associated with a significant decrease in nosocomial infections in study departments. Copyright © 2012 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.