NIF ICCS network design and loading analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tietbohl, G; Bryant, R
The National Ignition Facility (NIF) is housed within a large facility about the size of two football fields. The Integrated Computer Control System (ICCS) is distributed throughout this facility and requires the integration of about 40,000 control points and over 500 video sources. This integration is provided by approximately 700 control computers distributed throughout the NIF facility and a network that provides the communication infrastructure. A main control room houses a set of seven computer consoles providing operator access and control of the various distributed front-end processors (FEPs). There are also remote workstations distributed within the facility that allow providemore » operator console functions while personnel are testing and troubleshooting throughout the facility. The operator workstations communicate with the FEPs which implement the localized control and monitoring functions. There are different types of FEPs for the various subsystems being controlled. This report describes the design of the NIF ICCS network and how it meets the traffic loads that will are expected and the requirements of the Sub-System Design Requirements (SSDR's). This document supersedes the earlier reports entitled Analysis of the National Ignition Facility Network, dated November 6, 1996 and The National Ignition Facility Digital Video and Control Network, dated July 9, 1996. For an overview of the ICCS, refer to the document NIF Integrated Computer Controls System Description (NIF-3738).« less
Interactive communication channel
NASA Astrophysics Data System (ADS)
Chan, R. H.; Mann, M. R.; Ciarrocchi, J. A.
1985-10-01
Discussed is an interactive communications channel (ICC) for providing a digital computer with high-performance multi-channel interfaces. Sixteen full duplex channels can be serviced in the ICC with the sequence or scan pattern being programmable and dependent upon the number or channels and their speed. A channel buffer system is used for line interface, and character exchange. The channel buffer system is on a byte basis. The ICC performs frame start and frame end functions, bit stripping and bit stuffing. Data is stored in a memory in block format (256 bytes maximum) by a program control and the ICC maintains byte address information and a block byte count. Data exchange with a memory is made by cycle steals. Error detection is also provided for using a cyclic redundancy check technique.
Xiong, Xiaorui R.; Liang, Feixue; Li, Haifu; Mesik, Lukas; Zhang, Ke K.; Polley, Daniel B.; Tao, Huizhong W.; Xiao, Zhongju; Zhang, Li I.
2013-01-01
Binaural integration in the central nucleus of inferior colliculus (ICC) plays a critical role in sound localization. However, its arithmetic nature and underlying synaptic mechanisms remain unclear. Here, we showed in mouse ICC neurons that the contralateral dominance is created by a “push-pull”-like mechanism, with contralaterally dominant excitation and more bilaterally balanced inhibition. Importantly, binaural spiking response is generated apparently from an ipsilaterally-mediated scaling of contralateral response, leaving frequency tuning unchanged. This scaling effect is attributed to a divisive attenuation of contralaterally-evoked synaptic excitation onto ICC neurons with their inhibition largely unaffected. Thus, a gain control mediates the linear transformation from monaural to binaural spike responses. The gain value is modulated by interaural level difference (ILD) primarily through scaling excitation to different levels. The ILD-dependent synaptic scaling and gain adjustment allow ICC neurons to dynamically encode interaural sound localization cues while maintaining an invariant representation of other independent sound attributes. PMID:23972599
Advanced information processing system: Inter-computer communication services
NASA Technical Reports Server (NTRS)
Burkhardt, Laura; Masotto, Tom; Sims, J. Terry; Whittredge, Roy; Alger, Linda S.
1991-01-01
The purpose is to document the functional requirements and detailed specifications for the Inter-Computer Communications Services (ICCS) of the Advanced Information Processing System (AIPS). An introductory section is provided to outline the overall architecture and functional requirements of the AIPS and to present an overview of the ICCS. An overview of the AIPS architecture as well as a brief description of the AIPS software is given. The guarantees of the ICCS are provided, and the ICCS is described as a seven-layered International Standards Organization (ISO) Model. The ICCS functional requirements, functional design, and detailed specifications as well as each layer of the ICCS are also described. A summary of results and suggestions for future work are presented.
Reliability of fMRI for Studies of Language in Post-Stroke Aphasia Subjects
Eaton, Kenneth P.; Szaflarski, Jerzy P.; Altaye, Mekibib; Ball, Angel L.; Kissela, Brett M.; Banks, Christi; Holland, Scott K.
2008-01-01
Quantifying change in brain activation patterns associated with post-stroke recovery and reorganization of language function over time requires accurate understanding of inter-scan and inter-subject variability. Here we report inter-scan variability measures for fMRI activation patterns associated with verb generation (VG) and semantic decision/tone decision (SDTD) tasks in 4 healthy controls and 4 aphasic left middle cerebral artery (LMCA) stroke subjects. A series of 10 fMRI scans was completed on a 4T Varian scanner for each task for each subject, except for one stroke subject who completed 5 and 6 scans for SDTD and VG, thus yielding 35 and 36 total stroke subject scans for SDTD and VG, respectively. Group composite and intraclass correlation coefficient (ICC) maps were computed across all subjects and trials for each task. The patterns of reliable activation for the VG and SDTD tasks correspond well to those regions typically activated by these tasks in healthy and aphasic subjects. ICCs for activation were consistently high (R0.05 ≈ 0.8) for individual tasks among both control and aphasic subjects. These voxel-wise measures of reliability highlight regions of low inter-scan variability within language circuitry for control and post-recovery stroke subjects. ICCs computed from the combination of the SDTD/VG data were markedly reduced for both control and aphasic subjects as compared with the ICCs for the individual tasks. These quantitative measures of inter-scan variability support the proposed use of these fMRI paradigms for longitudinal mapping of neural reorganization of language processing following left hemispheric insult. PMID:18411061
ICCE/ICCAI 2000 Full & Short Papers (Computer-Assisted Language Learning).
ERIC Educational Resources Information Center
2000
This document contains the following full and short papers on computer-assisted language learning (CALL) from ICCE/ICCAI 2000 (International Conference on Computers in Education/International Conference on Computer-Assisted Instruction): (1) "A Computer-Assisted English Abstract Words Learning Environment on the Web" (Wenli Tsou and…
Whiffin, Nicola; Walsh, Roddy; Govind, Risha; Edwards, Matthew; Ahmad, Mian; Zhang, Xiaolei; Tayal, Upasana; Buchan, Rachel; Midwinter, William; Wilk, Alicja E; Najgebauer, Hanna; Francis, Catherine; Wilkinson, Sam; Monk, Thomas; Brett, Laura; O'Regan, Declan P; Prasad, Sanjay K; Morris-Rosendahl, Deborah J; Barton, Paul J R; Edwards, Elizabeth; Ware, James S; Cook, Stuart A
2018-01-25
PurposeInternationally adopted variant interpretation guidelines from the American College of Medical Genetics and Genomics (ACMG) are generic and require disease-specific refinement. Here we developed CardioClassifier (http://www.cardioclassifier.org), a semiautomated decision-support tool for inherited cardiac conditions (ICCs).MethodsCardioClassifier integrates data retrieved from multiple sources with user-input case-specific information, through an interactive interface, to support variant interpretation. Combining disease- and gene-specific knowledge with variant observations in large cohorts of cases and controls, we refined 14 computational ACMG criteria and created three ICC-specific rules.ResultsWe benchmarked CardioClassifier on 57 expertly curated variants and show full retrieval of all computational data, concordantly activating 87.3% of rules. A generic annotation tool identified fewer than half as many clinically actionable variants (64/219 vs. 156/219, Fisher's P = 1.1 × 10 -18 ), with important false positives, illustrating the critical importance of disease and gene-specific annotations. CardioClassifier identified putatively disease-causing variants in 33.7% of 327 cardiomyopathy cases, comparable with leading ICC laboratories. Through addition of manually curated data, variants found in over 40% of cardiomyopathy cases are fully annotated, without requiring additional user-input data.ConclusionCardioClassifier is an ICC-specific decision-support tool that integrates expertly curated computational annotations with case-specific data to generate fast, reproducible, and interactive variant pathogenicity reports, according to best practice guidelines.GENETICS in MEDICINE advance online publication, 25 January 2018; doi:10.1038/gim.2017.258.
ERIC Educational Resources Information Center
Chen, Gwo-Dong; Chen, Chun-Hsiang; Wang, Chin-Yeh; Li, Liang-Yi
2012-01-01
The article aims to compare international conferences, "The International Educational Technology Conference" (IETC, 2011) and "The International Conference on Computers in Education" (ICCE, 2010), from various dimensions. The comparison is expected to conclude a better approach for every IETC and ICCE to be held. (Contains 4…
Java Tool Framework for Automation of Hardware Commissioning and Maintenance Procedures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ho, J C; Fisher, J M; Gordon, J B
2007-10-02
The National Ignition Facility (NIF) is a 192-beam laser system designed to study high energy density physics. Each beam line contains a variety of line replaceable units (LRUs) that contain optics, stepping motors, sensors and other devices to control and diagnose the laser. During commissioning and subsequent maintenance of the laser, LRUs undergo a qualification process using the Integrated Computer Control System (ICCS) to verify and calibrate the equipment. The commissioning processes are both repetitive and tedious when we use remote manual computer controls, making them ideal candidates for software automation. Maintenance and Commissioning Tool (MCT) software was developed tomore » improve the efficiency of the qualification process. The tools are implemented in Java, leveraging ICCS services and CORBA to communicate with the control devices. The framework provides easy-to-use mechanisms for handling configuration data, task execution, task progress reporting, and generation of commissioning test reports. The tool framework design and application examples will be discussed.« less
ICCE/ICCAI 2000 Full & Short Papers (Artificial Intelligence in Education).
ERIC Educational Resources Information Center
2000
This document contains the full and short papers on artificial intelligence in education from ICCE/ICCAI 2000 (International Conference on Computers in Education/International Conference on Computer-Assisted Instruction) covering the following topics: a computational model for learners' motivation states in individualized tutoring system; a…
ICCE/ICCAI 2000 Full & Short Papers (Student Modeling).
ERIC Educational Resources Information Center
2000
This document contains the following full and short papers on student modeling from ICCE/ICCAI 2000 (International Conference on Computers in Education/International Conference on Computer-Assisted Instruction): (1) "A Computational Model for Learner's Motivation States in Individualized Tutoring System" (Behrouz H. Far and Anete H.…
ICCE/ICCAI 2000 Full & Short Papers (Web-Based Learning).
ERIC Educational Resources Information Center
2000
This document contains full and short papers on World Wide Web-based learning from ICCE/ICCAI 2000 (International Conference on Computers in Education/International Conference on Computer-Assisted Instruction). Topics covered include: design and development of CAL (Computer Assisted Learning) systems; design and development of WBI (Web-Based…
ICCE/ICCAI 2000 Keynote Papers.
ERIC Educational Resources Information Center
2000
This document contains the four keynote papers from ICCE/ICCAI 2000 (International Conference on Computers in Education/International Conference on Computer-Assisted Instruction). "Using Technologies To Model Student Problem Spaces" (David Jonassen) contrasts examples of semantic network, expert system, and systems modeling…
ICCE/ICCAI 2000 Full & Short Papers (Collaborative Learning).
ERIC Educational Resources Information Center
2000
This document contains the full and short papers on collaborative learning from ICCE/ICCAI 2000 (International Conference on Computers in Education/International Conference on Computer-Assisted Instruction) covering the following topics: comparison of applying Internet to cooperative and traditional learning; a distributed backbone system for…
ICCE/ICCAI 2000 Full & Short Papers (Creative Learning).
ERIC Educational Resources Information Center
2000
This document contains the following full and short papers on creative learning from ICCE/ICCAI 2000 (International Conference on Computers in Education/International Conference on Computer-Assisted Instruction): (1) "A Collaborative Learning Support System Based on Virtual Environment Server for Multiple Agents" (Takashi Ohno, Kenji…
ICCE/ICCAI 2000 Full & Short Papers (Others).
ERIC Educational Resources Information Center
2000
This document contains the following full and short papers from ICCE/ICCAI 2000 (International Conference on Computers in Education/International Conference on Computer-Assisted Instruction): (1) "A Code Restructuring Tool To Help Scaffold Novice Programmers" (Stuart Garner); (2) "An Assessment Framework for Information Technology Integrated…
ICCE/ICCAI 2000 Full & Short Papers (Virtual Lab/Classroom/School).
ERIC Educational Resources Information Center
2000
This document contains the following full and short papers on virtual laboratories, classrooms, and schools from ICCE/ICCAI 2000 (International Conference on Computers in Education/International Conference on Computer-Assisted Instruction): (1) "A Collaborative Learning Support System Based on Virtual Environment Server for Multiple…
Valle, Susanne Collier; Støen, Ragnhild; Sæther, Rannei; Jensenius, Alexander Refsum; Adde, Lars
2015-10-01
A computer-based video analysis has recently been presented for quantitative assessment of general movements (GMs). This method's test-retest reliability, however, has not yet been evaluated. The aim of the current study was to evaluate the test-retest reliability of computer-based video analysis of GMs, and to explore the association between computer-based video analysis and the temporal organization of fidgety movements (FMs). Test-retest reliability study. 75 healthy, term-born infants were recorded twice the same day during the FMs period using a standardized video set-up. The computer-based movement variables "quantity of motion mean" (Qmean), "quantity of motion standard deviation" (QSD) and "centroid of motion standard deviation" (CSD) were analyzed, reflecting the amount of motion and the variability of the spatial center of motion of the infant, respectively. In addition, the association between the variable CSD and the temporal organization of FMs was explored. Intraclass correlation coefficients (ICC 1.1 and ICC 3.1) were calculated to assess test-retest reliability. The ICC values for the variables CSD, Qmean and QSD were 0.80, 0.80 and 0.86 for ICC (1.1), respectively; and 0.80, 0.86 and 0.90 for ICC (3.1), respectively. There were significantly lower CSD values in the recordings with continual FMs compared to the recordings with intermittent FMs (p<0.05). This study showed high test-retest reliability of computer-based video analysis of GMs, and a significant association between our computer-based video analysis and the temporal organization of FMs. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
ICCE/ICCAI 2000 Full & Short Papers (Knowledge Construction and Navigation).
ERIC Educational Resources Information Center
2000
This document contains the following full and short papers on knowledge construction and navigation from ICCE/ICCAI 2000 (International Conference on Computers in Education/International Conference on Computer-Assisted Instruction): (1) "An XML-Based Tool for Building and Using Conceptual Maps in Education and Training Environments"…
ICCE/ICCAI 2000 Full & Short Papers (Lifelong Learning).
ERIC Educational Resources Information Center
2000
This document contains the following full and short papers on lifelong learning from ICCE/ICCAI 2000 (International Conference on Computers in Education/International Conference on Computer-Assisted Instruction): (1) "A Study on the School Information Technology Pilot Scheme: Possibilities of Creative and Lifelong Learning" (Siu-Cheung Kong,…
ICCE/ICCAI 2000 Full & Short Papers (Educational Agent).
ERIC Educational Resources Information Center
2000
This document contains the full text of the following papers on educational agent from ICCE/ICCAI 2000 (International Conference on Computers in Education/International Conference on Computer-Assisted Instruction): (1) "An Agent-Based Intelligent Tutoring System" (C.M. Bruff and M.A. Williams); (2) "Design of Systematic Concept…
ICCE/ICCAI 2000 Full & Short Papers (Intelligent Tutoring Systems).
ERIC Educational Resources Information Center
2000
This document contains the full and short papers on intelligent tutoring systems (ITS) from ICCE/ICCAI 2000 (International Conference on Computers in Education/International Conference on Computer-Assisted Instruction) covering the following topics: a framework for Internet-based distributed learning; a fuzzy-based assessment for the Perl tutoring…
ICCE/ICCAI 2000 Full & Short Papers (Interactive Learning Environments).
ERIC Educational Resources Information Center
2000
This document contains the full and short papers on interactive learning environments from ICCE/ICCAI 2000 (International Conference on Computers in Education/International Conference on Computer-Assisted Instruction) covering the following topics: a CAL system for appreciation of 3D shapes by surface development; a constructivist virtual physics…
ICCE/ICCAI 2000 Full & Short Papers (System Design and Development).
ERIC Educational Resources Information Center
2000
This document contains the full and short papers on system design and development from ICCE/ICCAI 2000 (International Conference on Computers in Education/International Conference on Computer-Assisted Instruction) covering the following topics: a code restructuring tool to help scaffold novice programmers; a framework for Internet-based…
ICCE/ICCAI 2000 Full & Short Papers (Multimedia and Hypermedia in Education).
ERIC Educational Resources Information Center
2000
This document contains the full and short papers on multimedia and hypermedia in education from ICCE/ICCAI 2000 (International Conference on Computers in Education/International Conference on Computer-Assisted Instruction) covering the following topics: learner-centered navigation path planning in world Wide Web-based learning; the relation…
ICCE/ICCAI 2000 Full & Short Papers (Methodologies).
ERIC Educational Resources Information Center
2000
This document contains the full text of the following full and short papers on methodologies from ICCE/ICCAI 2000 (International Conference on Computers in Education/International Conference on Computer-Assisted Instruction): (1) "A Methodology for Learning Pattern Analysis from Web Logs by Interpreting Web Page Contents" (Chih-Kai Chang and…
ICCE/ICCAI 2000 Full & Short Papers (Teaching and Learning Processes).
ERIC Educational Resources Information Center
2000
This document contains the full and short papers on teaching and learning processes from ICCE/ICCAI 2000 (International Conference on Computers in Education/International Conference on Computer-Assisted Instruction) covering the following topics: a code restructuring tool to help scaffold novice programmers; efficient study of Kanji using…
Endogenous sex steroids and risk of cervical carcinoma: results from the EPIC study.
Rinaldi, Sabina; Plummer, Martyn; Biessy, Carine; Castellsagué, Xavier; Overvad, Kim; Krüger Kjær, Susanne; Tjønneland, Anne; Clavel-Chapelon, Françoise; Chabbert-Buffet, Nathalie; Mesrine, Sylvie; Lukanova, Annekatrin; Kaaks, Rudolf; Weikert, Cornelia; Boeing, Heiner; Trichopoulou, Antonia; Lagiou, Pagona; Trichopoulos, Dimitrios; Palli, Domenico; Agnoli, Claudia; Tumino, Rosario; Vineis, Paolo; Panico, Salvatore; Bueno-de-Mesquita, Bas; van Kranen, Henk J; Peeters, Petra Hm; Bakken, Kjersti; Lund, Eiliv; Gram, Inger Torhild; Rodríguez, Laudina; Bosch, F Xavier; Sánchez, Maria-José; Dorronsoro, Miren; Navarro, Carmen; Gurrea, Aurelio Barricarte; Kjellberg, Lennart; Dillner, Joakim; Manjer, Jonas; Butt, Salma; Khaw, Kay-Tee; Wareham, Nicholas; Allen, Naomi E; Travis, Ruth; Romieu, Isabelle; Ferrari, Pietro; Riboli, Elio; Franceschi, Silvia
2011-12-01
Epidemiologic data and animal models suggest that, despite the predominant role of human papillomavirus infection, sex steroid hormones are also involved in the etiology of invasive cervical carcinoma (ICC). Ninety-nine ICC cases, 121 cervical intraepithelial neoplasia grade 3 (CIN3) cases and 2 control women matched with each case for center, age, menopausal status and blood collection-related variables, were identified in the European Prospective Investigation into Cancer and Nutrition (EPIC) study. Circulating levels of testosterone (T) and estradiol (E(2)); dehydroepiandrosterone sulfate (DHEAS); progesterone (premenopausal women); and sex hormone-binding globulin (SHBG) were measured using immunoassays. Levels of free (f) T and E(2) were calculated from absolute concentrations of T, E(2), and SHBG. Odds ratios (ORs) and 95% confidence intervals (CI) were computed using regularized conditional logistic regression. Among premenopausal women, associations with ICC were observed for fT (OR for highest vs. lowest tertile = 5.16, 95% CI, 1.50-20.1). SHBG level was associated with a significant downward trend in ICC risk. T, E(2), fE(2), and DHEAS showed nonsignificant positive association with ICC. Progesterone was uninfluential. Among postmenopausal women, associations with ICC were found for T (OR = 3.14; 95% CI, 1.21-9.37), whereas E(2) and fT showed nonsignificant positive association. SHBG level was unrelated to ICC risk in postmenopausal women. No associations between any hormone and CIN3 were detected in either pre- or postmenopausal women. Our findings suggest for the first time that T and possibly E(2) may be involved in the etiology of ICC. The responsiveness of cervical tumors to hormone modulators is worth exploring.
ICCE/ICCAI 2000 Full & Short Papers (Evaluation of Learning and Systems).
ERIC Educational Resources Information Center
2000
This document contains the full and short papers on evaluation of learning and systems from ICCE/ICCAI 2000 (International Conference on Computers in Education/International Conference on Computer-Assisted Instruction) covering the following topics: a new method for efficient study of Kanji using mnemonics and software; a study on the relation…
Qualitative evaluation and economic estimates of an infection control champions program.
Lloyd-Smith, Elisa; Curtin, Jim; Gilbart, Wayne; Romney, Marc G
2014-12-01
In many North American hospitals, conventional infection control operational models often struggle to provide sufficient support to frontline health care workers. The objective of this study was to describe a sustainable infection control champion (ICC) program based on findings from focus groups. A distributed model of infection control was established by placing infection prevention and control-trained ICCs in 3 Canadian hospitals for a period of 12 months. Subsequently, semistructured focus groups were conducted to describe overall feasibility and impeding and critical factors affecting sustainability. An economic estimate of the ICC program compared with the cost of hiring a new infection control practitioner was also calculated. Focus group participants considered the program feasible. Barriers included lack of time and staff turnover. Themes critical for the successful implementation of an ICC program included defined ICC roles and goals, adequate support and resources for the ICC, engagement with all levels of staff, flexible structure, and program evaluation. The cost per bed of the ICC program was less than the cost per bed of hiring a new infection control practitioner. A distributed model of providing infection prevention and control services may have benefit when hospital infection control teams are underresourced, as is often the case. Several key factors are needed for the successful implementation of an ICC program. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
ICCE/ICCAI 2000 Full & Short Papers (Virtual Reality in Education).
ERIC Educational Resources Information Center
2000
This document contains the full text of the following full and short papers on virtual reality in education from ICCE/ICCAI 2000 (International Conference on Computers in Education/International Conference on Computer-Assisted Instruction): (1) "A CAL System for Appreciation of 3D Shapes by Surface Development (C3D-SD)" (Stephen C. F. Chan, Andy…
An intelligent automated command and control system for spacecraft mission operations
NASA Technical Reports Server (NTRS)
Stoffel, A. William
1994-01-01
The Intelligent Command and Control (ICC) System research project is intended to provide the technology base necessary for producing an intelligent automated command and control (C&C) system capable of performing all the ground control C&C functions currently performed by Mission Operations Center (MOC) project Flight Operations Team (FOT). The ICC research accomplishments to date, details of the ICC, and the planned outcome of the ICC research, mentioned above, are discussed in detail.
Evaluation of the intelligent cruise control system : volume 1 : study results
DOT National Transportation Integrated Search
1999-10-01
The Intelligent Cruise Control (ICC) system evaluation was based on an ICC Field Operational Test (FOT) performed in Michigan. The FOT involved 108 volunteers recruited to drive ten ICC-equipped Chrysler Concordes. Testing was initiated in July 1996 ...
Control and Information Systems for the National Ignition Facility
Brunton, Gordon; Casey, Allan; Christensen, Marvin; ...
2017-03-23
Orchestration of every National Ignition Facility (NIF) shot cycle is managed by the Integrated Computer Control System (ICCS), which uses a scalable software architecture running code on more than 1950 front-end processors, embedded controllers, and supervisory servers. The ICCS operates laser and industrial control hardware containing 66 000 control and monitor points to ensure that all of NIF’s laser beams arrive at the target within 30 ps of each other and are aligned to a pointing accuracy of less than 50 μm root-mean-square, while ensuring that a host of diagnostic instruments record data in a few billionths of a second.more » NIF’s automated control subsystems are built from a common object-oriented software framework that distributes the software across the computer network and achieves interoperation between different software languages and target architectures. A large suite of business and scientific software tools supports experimental planning, experimental setup, facility configuration, and post-shot analysis. Standard business services using open-source software, commercial workflow tools, and database and messaging technologies have been developed. An information technology infrastructure consisting of servers, network devices, and storage provides the foundation for these systems. Thus, this work is an overview of the control and information systems used to support a wide variety of experiments during the National Ignition Campaign.« less
Control and Information Systems for the National Ignition Facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brunton, Gordon; Casey, Allan; Christensen, Marvin
Orchestration of every National Ignition Facility (NIF) shot cycle is managed by the Integrated Computer Control System (ICCS), which uses a scalable software architecture running code on more than 1950 front-end processors, embedded controllers, and supervisory servers. The ICCS operates laser and industrial control hardware containing 66 000 control and monitor points to ensure that all of NIF’s laser beams arrive at the target within 30 ps of each other and are aligned to a pointing accuracy of less than 50 μm root-mean-square, while ensuring that a host of diagnostic instruments record data in a few billionths of a second.more » NIF’s automated control subsystems are built from a common object-oriented software framework that distributes the software across the computer network and achieves interoperation between different software languages and target architectures. A large suite of business and scientific software tools supports experimental planning, experimental setup, facility configuration, and post-shot analysis. Standard business services using open-source software, commercial workflow tools, and database and messaging technologies have been developed. An information technology infrastructure consisting of servers, network devices, and storage provides the foundation for these systems. Thus, this work is an overview of the control and information systems used to support a wide variety of experiments during the National Ignition Campaign.« less
Jung, Dong-Hwan; Hwang, Shin; Song, Gi-Won; Ahn, Chul-Soo; Moon, Deok-Bog; Kim, Ki-Hun; Ha, Tae-Yong; Park, Gil-Chun; Hong, Seung-Mo; Kim, Wan-Jun; Kang, Woo-Hyoung; Kim, Seok-Hwan; Yu, Eun Sil; Lee, Sung-Gyu
2017-01-26
BACKGROUND Intrahepatic cholangiocarcinoma (ICC) can be incidentally diagnosed after liver transplantation (LT). We investigated the clinicopathological features of LT recipients with ICC and compared prognosis with that of the control group. MATERIAL AND METHODS We identified 16 recipients with ICC in our institutional database. The propensity score-matched control group comprised 100 ICC patients who underwent hepatic resection (HR). RESULTS ICC incidence was 0.5% in all adult LT patients and 1.2% in adult recipients with primary liver cancer. Mean age was 58.0±4.8 years and 15 were male. All ICCs were diagnosed incidentally in the explanted livers. Mean ICC tumor diameter was 2.5±1.1 cm and 14 recipients had a single tumor. Tumor stages were I in 9, II in 5, and IV in 2. Concurrent second primary liver cancer was detected as hepatocellular carcinoma in 7 and combined hepatocellular carcinoma-cholangiocarcinoma in 1. Tumor recurrence and patient survival rates were 56.2% and 81.3% at 1 year and 78.1% and 52.4% at 5 years, respectively. Presence of second cancer did not affect tumor recurrence (p=0.959) or patient survival (p=0.737). All 3 patients with very early ICC did not show ICC recurrence. Compared with the control group, the tumor recurrence rate was higher after LT (p=0.024), but this difference disappeared after analysis was confined to recipients with ICC alone (p=0.121). Post-recurrence survival was not different after HR and LT (p=0.082). CONCLUSIONS ICC is rarely diagnosed after LT and half of such patients have second liver cancer. Post-transplant prognosis of ICC is poor except for very early ICC; thus, strict surveillance is mandatory.
Multicenter reliability of semiautomatic retinal layer segmentation using OCT
Oberwahrenbrock, Timm; Traber, Ghislaine L.; Lukas, Sebastian; Gabilondo, Iñigo; Nolan, Rachel; Songster, Christopher; Balk, Lisanne; Petzold, Axel; Paul, Friedemann; Villoslada, Pablo; Brandt, Alexander U.; Green, Ari J.
2018-01-01
Objective To evaluate the inter-rater reliability of semiautomated segmentation of spectral domain optical coherence tomography (OCT) macular volume scans. Methods Macular OCT volume scans of left eyes from 17 subjects (8 patients with MS and 9 healthy controls) were automatically segmented by Heidelberg Eye Explorer (v1.9.3.0) beta-software (Spectralis Viewing Module v6.0.0.7), followed by manual correction by 5 experienced operators from 5 different academic centers. The mean thicknesses within a 6-mm area around the fovea were computed for the retinal nerve fiber layer, ganglion cell layer (GCL), inner plexiform layer (IPL), inner nuclear layer, outer plexiform layer (OPL), and outer nuclear layer (ONL). Intraclass correlation coefficients (ICCs) were calculated for mean layer thickness values. Spatial distribution of ICC values for the segmented volume scans was investigated using heat maps. Results Agreement between raters was good (ICC > 0.84) for all retinal layers, particularly inner retinal layers showed excellent agreement across raters (ICC > 0.96). Spatial distribution of ICC showed highest values in the perimacular area, whereas the ICCs were poorer for the foveola and the more peripheral macular area. The automated segmentation of the OPL and ONL required the most correction and showed the least agreement, whereas differences were less prominent for the remaining layers. Conclusions Automated segmentation with manual correction of macular OCT scans is highly reliable when performed by experienced raters and can thus be applied in multicenter settings. Reliability can be improved by restricting analysis to the perimacular area and compound segmentation of GCL and IPL. PMID:29552598
Chaplais, Elodie; Greene, David; Hood, Anita; Telfer, Scott; du Toit, Verona; Singh-Grewal, Davinder; Burns, Joshua; Rome, Keith; Schiferl, Daniel J; Hendry, Gordon J
2014-07-19
Peripheral quantitative computed tomography (pQCT) is an established technology that allows for the measurement of the material properties of bone. Alterations to bone architecture are associated with an increased risk of fracture. Further pQCT research is necessary to identify regions of interest that are prone to fracture risk in people with chronic diseases. The second metatarsal is a common site for the development of insufficiency fractures, and as such the aim of this study was to assess the reproducibility of a novel scanning protocol of the second metatarsal using pQCT. Eleven embalmed cadaveric leg specimens were scanned six times; three times with and without repositioning. Each foot was positioned on a custom-designed acrylic foot plate to permit unimpeded scans of the region of interest. Sixty-six scans were obtained at 15% (distal) and 50% (mid shaft) of the second metatarsal. Voxel size and scan speed were reduced to 0.40 mm and 25 mm.sec(-1). The reference line was positioned at the most distal portion of the 2(nd) metatarsal. Repeated measurements of six key variables related to bone properties were subject to reproducibility testing. Data were log transformed and reproducibility of scans were assessed using intraclass correlation coefficients (ICC) and coefficients of variation (CV%). Reproducibility of the measurements without repositioning were estimated as: trabecular area (ICC 0.95; CV% 2.4), trabecular density (ICC 0.98; CV% 3.0), Strength Strain Index (SSI) - distal (ICC 0.99; CV% 5.6), cortical area (ICC 1.0; CV% 1.5), cortical density (ICC 0.99; CV% 0.1), SSI - mid shaft (ICC 1.0; CV% 2.4). Reproducibility of the measurements after repositioning were estimated as: trabecular area (ICC 0.96; CV% 2.4), trabecular density (ICC 0.98; CV% 2.8), SSI - distal (ICC 1.0; CV% 3.5), cortical area (ICC 0.99; CV%2.4), cortical density (ICC 0.98; CV% 0.8), SSI - mid shaft (ICC 0.99; CV% 3.2). The scanning protocol generated excellent reproducibility for key bone properties measured at the distal and mid-shaft regions of the 2(nd) metatarsal. This protocol extends the capabilities of pQCT to evaluate bone quality in people who may be at an increased risk of metatarsal insufficiency fractures.
2014-01-01
Background Peripheral quantitative computed tomography (pQCT) is an established technology that allows for the measurement of the material properties of bone. Alterations to bone architecture are associated with an increased risk of fracture. Further pQCT research is necessary to identify regions of interest that are prone to fracture risk in people with chronic diseases. The second metatarsal is a common site for the development of insufficiency fractures, and as such the aim of this study was to assess the reproducibility of a novel scanning protocol of the second metatarsal using pQCT. Methods Eleven embalmed cadaveric leg specimens were scanned six times; three times with and without repositioning. Each foot was positioned on a custom-designed acrylic foot plate to permit unimpeded scans of the region of interest. Sixty-six scans were obtained at 15% (distal) and 50% (mid shaft) of the second metatarsal. Voxel size and scan speed were reduced to 0.40 mm and 25 mm.sec-1. The reference line was positioned at the most distal portion of the 2nd metatarsal. Repeated measurements of six key variables related to bone properties were subject to reproducibility testing. Data were log transformed and reproducibility of scans were assessed using intraclass correlation coefficients (ICC) and coefficients of variation (CV%). Results Reproducibility of the measurements without repositioning were estimated as: trabecular area (ICC 0.95; CV% 2.4), trabecular density (ICC 0.98; CV% 3.0), Strength Strain Index (SSI) - distal (ICC 0.99; CV% 5.6), cortical area (ICC 1.0; CV% 1.5), cortical density (ICC 0.99; CV% 0.1), SSI – mid shaft (ICC 1.0; CV% 2.4). Reproducibility of the measurements after repositioning were estimated as: trabecular area (ICC 0.96; CV% 2.4), trabecular density (ICC 0.98; CV% 2.8), SSI - distal (ICC 1.0; CV% 3.5), cortical area (ICC 0.99; CV%2.4), cortical density (ICC 0.98; CV% 0.8), SSI – mid shaft (ICC 0.99; CV% 3.2). Conclusions The scanning protocol generated excellent reproducibility for key bone properties measured at the distal and mid-shaft regions of the 2nd metatarsal. This protocol extends the capabilities of pQCT to evaluate bone quality in people who may be at an increased risk of metatarsal insufficiency fractures. PMID:25037451
Baker, Nancy A; Cook, James R; Redfern, Mark S
2009-01-01
This paper describes the inter-rater and intra-rater reliability, and the concurrent validity of an observational instrument, the Keyboard Personal Computer Style instrument (K-PeCS), which assesses stereotypical postures and movements associated with computer keyboard use. Three trained raters independently rated the video clips of 45 computer keyboard users to ascertain inter-rater reliability, and then re-rated a sub-sample of 15 video clips to ascertain intra-rater reliability. Concurrent validity was assessed by comparing the ratings obtained using the K-PeCS to scores developed from a 3D motion analysis system. The overall K-PeCS had excellent reliability [inter-rater: intra-class correlation coefficients (ICC)=.90; intra-rater: ICC=.92]. Most individual items on the K-PeCS had from good to excellent reliability, although six items fell below ICC=.75. Those K-PeCS items that were assessed for concurrent validity compared favorably to the motion analysis data for all but two items. These results suggest that most items on the K-PeCS can be used to reliably document computer keyboarding style.
Interrater reliability assessment using the Test of Gross Motor Development-2.
Barnett, Lisa M; Minto, Christine; Lander, Natalie; Hardy, Louise L
2014-11-01
The aim was to examine interrater reliability of the object control subtest from the Test of Gross Motor Development-2 by live observation in a school field setting. Reliability Study--cross sectional. Raters were rated on their ability to agree on (1) the raw total for the six object control skills; (2) each skill performance and (3) the skill components. Agreement for the object control subtest and the individual skills was assessed by an intraclass correlation (ICC) and a kappa statistic assessed for skill component agreement. A total of 37 children (65% girls) aged 4-8 years (M = 6.2, SD = 0.8) were assessed in six skills by two raters; equating to 222 skill tests. Interrater reliability was excellent for the object control subset (ICC = 0.93), and for individual skills, highest for the dribble (ICC = 0.94) followed by strike (ICC = 0.85), overhand throw (ICC = 0.84), underhand roll (ICC = 0.82), kick (ICC = 0.80) and the catch (ICC = 0.71). The strike and the throw had more components with less agreement. Even though the overall subtest score and individual skill agreement was good, some skill components had lower agreement, suggesting these may be more problematic to assess. This may mean some skill components need to be specified differently in order to improve component reliability. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.
Choosing the best index for the average score intraclass correlation coefficient.
Shieh, Gwowen
2016-09-01
The intraclass correlation coefficient (ICC)(2) index from a one-way random effects model is widely used to describe the reliability of mean ratings in behavioral, educational, and psychological research. Despite its apparent utility, the essential property of ICC(2) as a point estimator of the average score intraclass correlation coefficient is seldom mentioned. This article considers several potential measures and compares their performance with ICC(2). Analytical derivations and numerical examinations are presented to assess the bias and mean square error of the alternative estimators. The results suggest that more advantageous indices can be recommended over ICC(2) for their theoretical implication and computational ease.
An overview of the CILBO spectral observation program
NASA Astrophysics Data System (ADS)
Rudawska, R.; Zender, J.; Koschny, D.
2016-01-01
The video equipment can be easily adopted with a spectral grating to obtain spectral information from meteors. Therefore, in recent years spectroscopic observations of meteors have become quite popular. The Meteor Research Group (MRG) of the European Space Agency has been working on upgrating the analysis of meteor spectra as well, operating image-intensified camera with objective grating (ICC8). ICC8 is located on Tenerife station of the double-station camera setup CILBO (Canary Island Long-Baseline Observatory). The pipeline software processes data with the standard calibration procedure (dark current, flat field, lens distortion corrections). While using the position of a meteor recorded by ICC7 camera (zero order), the position of the 1st order spectrum as a function of wavelength is computed Moreover, thanks to the double meteor observations carried by ICC7 (Tenerife) and ICC9 (La Palma), trajectory of a meteor and its orbit is determined. Which merged with simultaneously measurement of meteor spectrum from ICC8, allow us to identify the source of the meteoroid. Here, we report on preliminary results from a sample of meteor spectra collected by CILBO-ICC8 camera since 2012.
Kemeny, Nancy; Kingham, T. Peter; Allen, Peter J.; D’Angelica, Michael I.; DeMatteo, Ronald P.; Betel, Doron; Klimstra, David; Jarnagin, William R.; Ventura, Andrea
2016-01-01
Background MicroRNAs (miRNAs) are potential biomarkers in various malignancies. We aim to characterize miRNA expression in intrahepatic cholangiocarcinoma (ICC) and identify circulating plasma miRNAs with potential diagnostic and prognostic utility. Methods Using deep-sequencing techniques, miRNA expression between tumor samples and non-neoplastic liver parenchyma were compared. Overexpressed miRNAs were measured in plasma from an independent cohort of patients with cholangiocarcinoma using RT-qPCR and compared with that healthy volunteers. The discriminatory ability of the evaluated plasma miRNAs between patients and controls was evaluated with receiving operating characteristic (ROC) curves. Results Small RNAs from 12 ICC and 11 tumor-free liver samples were evaluated. Unsupervised hierarchical clustering using the miRNA expression data showed clear grouping of ICC vs. non-neoplastic liver parenchyma. We identified 134 down-regulated and 128 upregulated miRNAs. Based on overexpression and high fold-change, miR21, miR200b, miR221, and miR34c were measured in plasma from an independent cohort of patients with ICC (n = 25) and healthy controls (n = 7). Significant overexpression of miR-21 and miR-221 was found in plasma from ICC patients. Furthermore, circulating miR-21 demonstrated a high discriminatory ability between patients with ICC and healthy controls (AUC: 0.94). Conclusion Among the differentially expressed miRNAs in ICC, miR-21 and miR-221 are overexpressed and detectable in the circulation. Plasma expression levels of these miRNAs, particularly miR-21, accurately differentiates patients with ICC from healthy controls and could potentially serve as adjuncts in diagnosis. Prospective validation and comparison with other hepatobiliary malignancies is required to establish their potential role as diagnostic and prognostic biomarkers. PMID:27685844
Use of anoctamin 1 (ANO1) to evaluate interstitial cells of Cajal in Hirschsprung's disease.
Coyle, David; Kelly, Danielle A M; O'Donnell, Anne Marie; Gillick, John; Puri, Prem
2016-02-01
Interstitial cells of Cajal (ICCs) are pacemaker cells involved in facilitating neurotransmission and the generation of slow electrical waves necessary for colonic peristalsis. Their distribution has been found to be abnormal in the aganglionic and ganglionic colon in Hirschsprung's disease (HSCR) using c-kit-labelling. Anoctamin-1 (ANO1) is a Ca(2+)-activated Cl(-) channel thought to be specifically expressed on ICCs. Unlike c-kit, it plays a key role in ICC pacemaker activity. We aimed to investigate the utility of ANO1 in evaluating the colonic ICC network in HSCR. We collected full-length pull-through specimens from children with HSCR (n = 10). Control colon specimens were collected at colostomy closure in children with anorectal malformation (n = 6). The distribution of ANO1 and c-kit expression was evaluated using immunofluorescence and confocal microscopy. ANO1 expression was quantified using Western blot analysis. ANO1 was not expressed on 23 % of c-kit immuno-positive cells in the circular muscle; however, 100 % of ANO1-positive ICCs were c-kit positive. The distribution of ANO1-positive ICCs was sparse in aganglionic colon, with a modest reduction in ICCs seen in the ganglionic colon in HSCR compared to controls (p = 0.044). ANO1 protein expression was reduced in aganglionic colon but similar in ganglionic colon relative to controls. ANO1 is preferential to c-kit in evaluating the ICC network in HSCR due to its specificity and functional importance. Abnormal distribution of ANO1-positive ICCs in the ganglionic colon in HSCR may contribute to persistent bowel symptoms in some patients after pull-through surgery.
Shargall, Yaron; Hanna, Wael C; Schneider, Laura; Schieman, Colin; Finley, Christian J; Tran, Anna; Demay, Shantel; Gosse, Carolyn; Bowen, James M; Blackhouse, Gord; Smith, Kevin
2016-01-01
The objective of the study was to evaluate the Integrated Comprehensive Care (ICC) program, a novel health system integration initiative that coordinates home care and hospital-based clinical services for patients undergoing major thoracic surgery relative to traditional home care delivery. Methods included a pilot retrospective cohort analysis that compared the intervention cohort (ICC), composed of all patients undergoing major thoracic surgery in the 2012-2013 fiscal year with a control cohort, who underwent surgery in the year before the initiation of ICC. Length of stay, hospital costs, readmission, and emergency room visit data were stratified by degree and approach of resection and compared using univariate logistic regression analysis. A total of 331 patients under ICC and 355 control patients were enrolled. Hospital stay was significantly shorter in patients under video-assisted thoracoscopic surgery (VATS) ICC (sublobar median 3 vs 4 days, P = 0.013; lobar median 4 vs 5 days, P = 0.051) but not for open resections. The frequency of emergency room visits within 60 days of surgery was lower for all stratification groups in the ICC cohort, except for VATS sublobar (25.7% control vs 13.9% ICC, P = 0.097). There were no significant differences in 60-day readmission frequency in any subcohort. The mean inpatient case cost was significantly lower for ICC VATS sublobar resections ($8505.39 vs $11,038.18, P = 0.007), with the other resection types trending lower for ICC but nonsignificant. In conclusion, a hospital-based, postdischarge, patient-centered program could potentially result in shorter hospital stay, fewer readmission and emergency room visits, costsavings, and no increase in adverse postdischarge outcomes after major thoracic surgery. Copyright © 2016 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Peng, Hsinyi; Lu, Wei-Hsin; Wang, Chao-I
2009-01-01
The purposes of this study were to identify the essential dimensions of intercultural communicative competence (ICC) and to establish a framework for assessing the ICC level of high school students that included a self-report inventory and scoring rubrics for online interaction in intercultural contexts. A total of 472 high school students from…
R package to estimate intracluster correlation coefficient with confidence interval for binary data.
Chakraborty, Hrishikesh; Hossain, Akhtar
2018-03-01
The Intracluster Correlation Coefficient (ICC) is a major parameter of interest in cluster randomized trials that measures the degree to which responses within the same cluster are correlated. There are several types of ICC estimators and its confidence intervals (CI) suggested in the literature for binary data. Studies have compared relative weaknesses and advantages of ICC estimators as well as its CI for binary data and suggested situations where one is advantageous in practical research. The commonly used statistical computing systems currently facilitate estimation of only a very few variants of ICC and its CI. To address the limitations of current statistical packages, we developed an R package, ICCbin, to facilitate estimating ICC and its CI for binary responses using different methods. The ICCbin package is designed to provide estimates of ICC in 16 different ways including analysis of variance methods, moments based estimation, direct probabilistic methods, correlation based estimation, and resampling method. CI of ICC is estimated using 5 different methods. It also generates cluster binary data using exchangeable correlation structure. ICCbin package provides two functions for users. The function rcbin() generates cluster binary data and the function iccbin() estimates ICC and it's CI. The users can choose appropriate ICC and its CI estimate from the wide selection of estimates from the outputs. The R package ICCbin presents very flexible and easy to use ways to generate cluster binary data and to estimate ICC and it's CI for binary response using different methods. The package ICCbin is freely available for use with R from the CRAN repository (https://cran.r-project.org/package=ICCbin). We believe that this package can be a very useful tool for researchers to design cluster randomized trials with binary outcome. Copyright © 2017 Elsevier B.V. All rights reserved.
Evaluation of the intelligent cruise control system. Volume 2, Appendices
DOT National Transportation Integrated Search
1999-10-01
The Intelligent Cruise Control (ICC) system evaluation was sponsored by the National Highway Traffic Safety Administration (NHTSA) and based on an ICC Field Operational Test (FOT) conducted under a cooperative agreement between the NHTSA and the Univ...
Costa, Ana C S; Dibai Filho, Almir V; Packer, Amanda C; Rodrigues-Bigaton, Delaine
2013-01-01
Infrared thermography is an aid tool that can be used to evaluate several pathologies given its efficiency in analyzing the distribution of skin surface temperature. To propose two forms of infrared image analysis of the masticatory and upper trapezius muscles, and to determine the intra and inter-rater reliability of both forms of analysis. Infrared images of masticatory and upper trapezius muscles of 64 female volunteers with and without temporomandibular disorder (TMD) were collected. Two raters performed the infrared image analysis, which occurred in two ways: temperature measurement of the muscle length and in central portion of the muscle. The Intraclass Correlation Coefficient (ICC) was used to determine the intra and inter-rater reliability. The ICC showed excellent intra and inter-rater values for both measurements: temperature measurement of the muscle length (TMD group, intra-rater, ICC ranged from 0.996 to 0.999, inter-rater, ICC ranged from 0.992 to 0.999; control group, intra-rater, ICC ranged from 0.993 to 0.998, inter-rater, ICC ranged from 0.990 to 0.998), and temperature measurement of the central portion of the muscle (TMD group, intra-rater, ICC ranged from 0.981 to 0.998, inter-rater, ICC ranged from 0.971 to 0.998; control group, intra-rater, ICC ranged from 0.887 to 0.996, inter-rater, ICC ranged from 0.852 to 0.996). The results indicated that temperature measurements of the masticatory and upper trapezius muscles carried out by the analysis of the muscle length and central portion yielded excellent intra and inter-rater reliability.
Maritime security report. October 1998 [U.S. international crime control strategy
DOT National Transportation Integrated Search
1998-10-01
To coordinate all relevant Federal agencies, the International Crime Control Strategy (ICCS) was developed. The ICCS is intended to provide a framework for integrating all facets for the Federal response to the direct and immediate threat internation...
Nakajima, Erica C; Frankland, Michael P; Johnson, Tucker F; Antic, Sanja L; Chen, Heidi; Chen, Sheau-Chiann; Karwoski, Ronald A; Walker, Ronald; Landman, Bennett A; Clay, Ryan D; Bartholmai, Brian J; Rajagopalan, Srinivasan; Peikert, Tobias; Massion, Pierre P; Maldonado, Fabien
2018-01-01
Lung adenocarcinoma (ADC), the most common lung cancer type, is recognized increasingly as a disease spectrum. To guide individualized patient care, a non-invasive means of distinguishing indolent from aggressive ADC subtypes is needed urgently. Computer-Aided Nodule Assessment and Risk Yield (CANARY) is a novel computed tomography (CT) tool that characterizes early ADCs by detecting nine distinct CT voxel classes, representing a spectrum of lepidic to invasive growth, within an ADC. CANARY characterization has been shown to correlate with ADC histology and patient outcomes. This study evaluated the inter-observer variability of CANARY analysis. Three novice observers segmented and analyzed independently 95 biopsy-confirmed lung ADCs from Vanderbilt University Medical Center/Nashville Veterans Administration Tennessee Valley Healthcare system (VUMC/TVHS) and the Mayo Clinic (Mayo). Inter-observer variability was measured using intra-class correlation coefficient (ICC). The average ICC for all CANARY classes was 0.828 (95% CI 0.76, 0.895) for the VUMC/TVHS cohort, and 0.852 (95% CI 0.804, 0.901) for the Mayo cohort. The most invasive voxel classes had the highest ICC values. To determine whether nodule size influenced inter-observer variability, an additional cohort of 49 sub-centimeter nodules from Mayo were also segmented by three observers, with similar ICC results. Our study demonstrates that CANARY ADC classification between novice CANARY users has an acceptably low degree of variability, and supports the further development of CANARY for clinical application.
Ndizeye, Zacharie; Vanden Broeck, Davy; Vermandere, Heleen; Bogers, John Paul; Van Geertruyden, Jean-Pierre
2018-01-16
Well-organized screening and treatment programmes are effective to prevent Invasive Cervical Cancer (ICC) in LMICs. To achieve this, the World Health Organization (WHO) recommends the involvement of existing health personnel in casu doctors, nurses, midwives in ICC prevention. A necessary precondition is that health personnel have appropriate knowledge about ICC. Therefore, to inform policy makers and training institutions in Burundi, we documented the knowledge and practices of general practitioners (GPs) at district hospital level towards ICC control. A descriptive cross-sectional survey was conducted from February to April, 2015 among all GPs working in government district hospitals. A structured questionnaire and a scoring system were used to assess knowledge and practices of GPs. The participation rate was 58.2%. Majority of GPs (76.3%) had appropriate knowledge (score > 70%) on cervical cancer disease; but some risk factors were less well known as smoking and the 2 most important oncogenic HPV. Only 8.4% of the participants had appropriate knowledge on ICC prevention: 55% of the participants were aware that HPV vaccination exists and 48.1% knew cryotherapy as a treatment method for CIN. Further, 15.3% was aware of VIA as a screening method. The majority of the participants (87%) never or rarely propose screening tests to their clients. Only 2 participants (1.5%) have already performed VIA/VILI. Wrong thoughts were also reported: 39.7% thought that CIN could be treated with radiotherapy; 3.1% thought that X-ray is a screening method. In this comprehensive assessment, we observed that Burundian GPs have a very low knowledge level about ICC prevention, screening and treatment. Suboptimal practices and wrong thoughts related to ICC screening and treatments have also been documented. We therefore recommend an adequate pre- and in-service training of GPs and most probably nurses on ICC control before setting up any public health intervention on ICC control.
ITERATIVE CIRCUIT COMPUTER: CHARACTERIZATION AND RESUME OF ADVANTAGES AND DISADVANTAGES.
universal embedding spaces follows. The report concludes with a discussion of some of the advantages and disadvantages of i.c.c. rganiation for computers constructed of microelectric modules. (Author)
Intra- and inter-rater reliability of digital image analysis for skin color measurement
Sommers, Marilyn; Beacham, Barbara; Baker, Rachel; Fargo, Jamison
2013-01-01
Background We determined the intra- and inter-rater reliability of data from digital image color analysis between an expert and novice analyst. Methods Following training, the expert and novice independently analyzed 210 randomly ordered images. Both analysts used Adobe® Photoshop lasso or color sampler tools based on the type of image file. After color correction with Pictocolor® in camera software, they recorded L*a*b* (L*=light/dark; a*=red/green; b*=yellow/blue) color values for all skin sites. We computed intra-rater and inter-rater agreement within anatomical region, color value (L*, a*, b*), and technique (lasso, color sampler) using a series of one-way intra-class correlation coefficients (ICCs). Results Results of ICCs for intra-rater agreement showed high levels of internal consistency reliability within each rater for the lasso technique (ICC ≥ 0.99) and somewhat lower, yet acceptable, level of agreement for the color sampler technique (ICC = 0.91 for expert, ICC = 0.81 for novice). Skin L*, skin b*, and labia L* values reached the highest level of agreement (ICC ≥ 0.92) and skin a*, labia b*, and vaginal wall b* were the lowest (ICC ≥ 0.64). Conclusion Data from novice analysts can achieve high levels of agreement with data from expert analysts with training and the use of a detailed, standard protocol. PMID:23551208
Intra- and inter-rater reliability of digital image analysis for skin color measurement.
Sommers, Marilyn; Beacham, Barbara; Baker, Rachel; Fargo, Jamison
2013-11-01
We determined the intra- and inter-rater reliability of data from digital image color analysis between an expert and novice analyst. Following training, the expert and novice independently analyzed 210 randomly ordered images. Both analysts used Adobe(®) Photoshop lasso or color sampler tools based on the type of image file. After color correction with Pictocolor(®) in camera software, they recorded L*a*b* (L*=light/dark; a*=red/green; b*=yellow/blue) color values for all skin sites. We computed intra-rater and inter-rater agreement within anatomical region, color value (L*, a*, b*), and technique (lasso, color sampler) using a series of one-way intra-class correlation coefficients (ICCs). Results of ICCs for intra-rater agreement showed high levels of internal consistency reliability within each rater for the lasso technique (ICC ≥ 0.99) and somewhat lower, yet acceptable, level of agreement for the color sampler technique (ICC = 0.91 for expert, ICC = 0.81 for novice). Skin L*, skin b*, and labia L* values reached the highest level of agreement (ICC ≥ 0.92) and skin a*, labia b*, and vaginal wall b* were the lowest (ICC ≥ 0.64). Data from novice analysts can achieve high levels of agreement with data from expert analysts with training and the use of a detailed, standard protocol. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Longo, F; Nicetto, T; Banzato, T; Savio, G; Drigo, M; Meneghello, R; Concheri, G; Isola, M
2018-02-01
The aim of this ex vivo study was to test a novel three-dimensional (3D) automated computer-aided design (CAD) method (aCAD) for the computation of femoral angles in dogs from 3D reconstructions of computed tomography (CT) images. The repeatability and reproducibility of three manual radiography, manual CT reconstructions and the aCAD method for the measurement of three femoral angles were evaluated: (1) anatomical lateral distal femoral angle (aLDFA); (2) femoral neck angle (FNA); and (3) femoral torsion angle (FTA). Femoral angles of 22 femurs obtained from 16 cadavers were measured by three blinded observers. Measurements were repeated three times by each observer for each diagnostic technique. Femoral angle measurements were analysed using a mixed effects linear model for repeated measures to determine the levels of intra-observer agreement (repeatability) and inter-observer agreement (reproducibility). Repeatability and reproducibility of measurements using the aCAD method were excellent (intra-class coefficients, ICCs≥0.98) for all three angles assessed. Manual radiography and CT exhibited excellent agreement for the aLDFA measurement (ICCs≥0.90). However, FNA repeatability and reproducibility were poor (ICCs<0.8), whereas FTA measurement showed slightly higher ICCs values, except for the radiographic reproducibility, which was poor (ICCs<0.8). The computation of the 3D aCAD method provided the highest repeatability and reproducibility among the tested methodologies. Copyright © 2017 Elsevier Ltd. All rights reserved.
Code of Ethical Conduct for Computer-Using Educators: An ICCE Policy Statement.
ERIC Educational Resources Information Center
Computing Teacher, 1987
1987-01-01
Prepared by the International Council for Computers in Education's Ethics and Equity Committee, this code of ethics for educators using computers covers nine main areas: curriculum issues, issues relating to computer access, privacy/confidentiality issues, teacher-related issues, student issues, the community, school organizational issues,…
Liu, Sulai; Jiang, Bo; Li, Hao; He, Zili; Lv, Pin; Peng, Chuang; Wang, Yonggang; Cheng, Wei; Xu, Zhengquan; Chen, Wei; Liu, Zhengkai; Zhang, Bao; Shen, Shengqian; Xiang, Shuanglin
2017-01-01
Wip1 has been shown to correlate with the metastasis/invasion of several tumors. This study was designed to investigate the clinical significance and biological function of Wip1 in intrahepatic cholangiocarcinoma (ICC). The expression of Wip1 was investigated in sixty human ICC biopsy samples by immunohistochemistry. Transient and stable knockdown of Wip1 in two human ICC cells (ICC-9810 and SSP25) were established using short hairpin RNA expression vector. Immunohistochemistry revealed that Wip1 was up-regulated in human ICC tissues (47/60, 78.3%). High levels of Wip1 in human ICC correlated with metastasis to the lymph metastasis (P=0.022). Genetic depletion of Wip1 in ICC cells resulted in significantly inhibited proliferation and invasion compared with controls. Most importantly, Wip1 down-regulation impaired tumor migration capacity of ICC cells in vivo. Subsequent investigations revealed that matrix metalloproteinase-2 (MMP-2) is an important target of Wip1. Consistently, in human ICC tissues, Wip1 level was positively correlated with MMP-2 expression. Taken together, our founding indicates that Wip1 may be a crucial regulator in the tumorigenicity and invasion of human ICC, Wip1 exerts its pro-invasion function at least in part through the MMP-2 signaling pathway, suggesting Wip1 as a potential therapeutic target for ICC. PMID:28915621
De Pooter, Jan; El Haddad, Milad; Stroobandt, Roland; De Buyzere, Marc; Timmermans, Frank
2017-06-01
QRS duration (QRSD) plays a key role in the field of cardiac resynchronization therapy (CRT). Computer-calculated QRSD assessments are widely used, however inter-manufacturer differences have not been investigated in CRT candidates. QRSD was assessed in 377 digitally stored ECGs: 139 narrow QRS, 140 LBBB and 98 ventricular paced ECGs. Manual QRSD was measured as global QRSD, using digital calipers, by two independent observers. Computer-calculated QRSD was assessed by Marquette 12SL (GE Healthcare, Waukesha, WI, USA) and SEMA3 (Schiller, Baar, Switzerland). Inter-manufacturer differences of computer-calculated QRSD assessments vary among different QRS morphologies: narrow QRSD: 4 [2-9] ms (median [IQR]), p=0.010; LBBB QRSD: 7 [2-10] ms, p=0.003 and paced QRSD: 13 [6-18] ms, p=0.007. Interobserver differences of manual QRSD assessments measured: narrow QRSD: 4 [2-6] ms, p=non-significant; LBBB QRSD: 6 [3-12] ms, p=0.006; paced QRSD: 8 [4-18] ms, p=0.001. In LBBB ECGs, intraclass correlation coefficients (ICCs) were comparable for inter-manufacturer and interobserver agreement (ICC 0.830 versus 0.837). When assessing paced QRSD, manual measurements showed higher ICC compared to inter-manufacturer agreement (ICC 0.902 versus 0.776). Using guideline cutoffs of 130ms, up to 15% of the LBBB ECGs would be misclassified as <130ms or ≥130ms by at least one method. Using a cutoff of 150ms, this number increases to 33% of ECGs being misclassified. However, by combining LBBB-morphology and QRSD, the number of misclassified ECGs can be decreased by half. Inter-manufacturer differences in computer-calculated QRSD assessments are significant and may compromise adequate selection of individual CRT candidates when using QRSD as sole parameter. Paced QRSD should preferentially be assessed by manual QRSD measurements. Copyright © 2017 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dugas, Alexandre; Therasse, Eric; Kauffmann, Claude
2012-08-15
Purpose: To compare different methods measuring abdominal aortic aneurysm (AAA) maximal diameter (Dmax) and its progression on multidetector computed tomography (MDCT) scan. Materials and Methods: Forty AAA patients with two MDCT scans acquired at different times (baseline and follow-up) were included. Three observers measured AAA diameters by seven different methods: on axial images (anteroposterior, transverse, maximal, and short-axis views) and on multiplanar reformation (MPR) images (coronal, sagittal, and orthogonal views). Diameter measurement and progression were compared over time for the seven methods. Reproducibility of measurement methods was assessed by intraclass correlation coefficient (ICC) and Bland-Altman analysis. Results: Dmax, as measuredmore » on axial slices at baseline and follow-up (FU) MDCTs, was greater than that measured using the orthogonal method (p = 0.046 for baseline and 0.028 for FU), whereas Dmax measured with the orthogonal method was greater those using all other measurement methods (p-value range: <0.0001-0.03) but anteroposterior diameter (p = 0.18 baseline and 0.10 FU). The greatest interobserver ICCs were obtained for the orthogonal and transverse methods (0.972) at baseline and for the orthogonal and sagittal MPR images at FU (0.973 and 0.977). Interobserver ICC of the orthogonal method to document AAA progression was greater (ICC = 0.833) than measurements taken on axial images (ICC = 0.662-0.780) and single-plane MPR images (0.772-0.817). Conclusion: AAA Dmax measured on MDCT axial slices overestimates aneurysm size. Diameter as measured by the orthogonal method is more reproducible, especially to document AAA progression.« less
Indirect current control with separate IZ drop compensation for voltage source converters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kanetkar, V.R.; Dawande, M.S.; Dubey, G.K.
1995-12-31
Indirect Current Control (ICC) of boost type Voltage Source Converters (VSCs) using separate compensation of line IZ voltage drop is presented. A separate bi-directional VSC is used to produce the compensation voltage. This simplifies the ICC regulator scheme as the power flow is controlled through single modulation index. Experimental verification is provided for bi-directional control of the power flow.
NASA Astrophysics Data System (ADS)
McCarthy, Ann
2006-01-01
The ICC Workflow WG serves as the bridge between ICC color management technologies and use of those technologies in real world color production applications. ICC color management is applicable to and is used in a wide range of color systems, from highly specialized digital cinema color special effects to high volume publications printing to home photography. The ICC Workflow WG works to align ICC technologies so that the color management needs of these diverse use case systems are addressed in an open, platform independent manner. This report provides a high level summary of the ICC Workflow WG objectives and work to date, focusing on the ways in which workflow can impact image quality and color systems performance. The 'ICC Workflow Primitives' and 'ICC Workflow Patterns and Dimensions' workflow models are covered in some detail. Consider the questions, "How much of dissatisfaction with color management today is the result of 'the wrong color transformation at the wrong time' and 'I can't get to the right conversion at the right point in my work process'?" Put another way, consider how image quality through a workflow can be negatively affected when the coordination and control level of the color management system is not sufficient.
Go, Ju Young; Kang, Bo Young; Hwang, Jin Hee; Oh, Kap Sung
2017-01-01
Efforts to prevent chest wall deformity after costal cartilage graft are ongoing. In this study, we introduce a new method to prevent donor site deformation using irradiated cadaver cartilage (ICC) and compare this method to the autogenous diced cartilage (ADC) technique. Forty-two pediatric patients comprised the ADC group (n = 24) and the ICC group (n = 18). After harvesting costal cartilage, the empty perichondrial space was filled with autologous diced cartilage in the ADC group and cadaver cartilage in the ICC group. Digital photographs and rib cartilage three-dimensional computed tomography (CT) data were analyzed to compare the preventive effect of donor site deformity. We compared the pre- and postoperative costal cartilage volumes using 3D-CT and graded the volumes (grade I: 0%-25%, grade II: 25%-50%, grade III: 50%-75%, and grade IV: 75%-100%). The average follow-up period was 20 and 24 months in the ADC and ICC groups, respectively. Grade IV maintenance of previous costal cartilage volume was evident postoperatively in 22% of patients in the ADC group and 82% of patients in the ICC group. Intercostal space narrowing and chest wall depression were less in the ICC group. There were no complications or severe resorption of cadaver cartilage. ICC support transected costal ring and prevented stability loss by acting as a spacer. The ICC technique is more effective in preventing intercostal space narrowing and chest wall depression than the ADC technique. Samsung Medical Center Institution Review Board, Unique protocol ID: 2009-10-006-008. This study is also registered on PRS (ClinicalTrials.gov Record 2009-10-006). Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Performance analysis of Integrated Communication and Control System networks
NASA Technical Reports Server (NTRS)
Halevi, Y.; Ray, A.
1990-01-01
This paper presents statistical analysis of delays in Integrated Communication and Control System (ICCS) networks that are based on asynchronous time-division multiplexing. The models are obtained in closed form for analyzing control systems with randomly varying delays. The results of this research are applicable to ICCS design for complex dynamical processes like advanced aircraft and spacecraft, autonomous manufacturing plants, and chemical and processing plants.
Krebs, Thomas; Boettcher, Michael; Schäfer, Hansjörg; Eschenburg, Georg; Wenke, Katharina; Appl, Birgit; Roth, Beate; Andreas, Thomas; Schmitz, Carla; Fahje, Rebecca; Jacobsen, Birthe; Tiemann, Bastian; Reinshagen, Konrad; Hecher, Kurt; Bergholz, Robert
2014-08-01
The pathogenesis of intestinal dysmotility in gastroschisis is not completely understood. Peel formation and disorganization of interstitial Cajal cells (ICC) have been proposed in humans. The aim of this study was to evaluate the impact of prenatal coverage of gastroschisis on gut inflammation and expression of ICC in a fetal lamb model. Twenty-one German blackhead sheep with an abdominal wall defect that was created fetoscopically on day 77 of 145 days gestation were used in this study. Intrauterine surgery with the aim to cover the defect was performed 3 weeks later; two fetuses were covered completely, 5 partially and 11 remained uncovered. Three fetuses without gastroschisis were used as controls. All fetuses were retrieved by cesarean section at day 135. Samples of the small intestine were stained with hematoxylin and eosin for histologic analysis of peel formation and serosal and muscular thickness. For ICC detection, immunohistochemistry using anti-CD117 (c-Kit) antibody was used. In all samples with exposure to amniotic fluid, peel formation and significantly decreased ICC were found. Complete coverage reduced peel formation and disorganization of ICC compared to uncovered animals almost to the level of controls. Peel formation and ICC derangement were significantly reduced by prenatal coverage of gastroschisis. Moreover, this animal model mimics the histopathological bowel changes as seen in human gastroschisis and may, therefore, be used for further research on the pathophysiology and fetal therapy of this malformation.
2012-01-01
Background Few studies discuss the indicators used to assess the effect on cost containment in healthcare across hospitals in a single-payer national healthcare system with constrained medical resources. We present the intraclass correlation coefficient (ICC) to assess how well Taiwan constrained hospital-provided medical services in such a system. Methods A custom Excel-VBA routine to record the distances of standard deviations (SDs) from the central line (the mean over the previous 12 months) of a control chart was used to construct and scale annual medical expenditures sequentially from 2000 to 2009 for 421 hospitals in Taiwan to generate the ICC. The ICC was then used to evaluate Taiwan’s year-based convergent power to remain unchanged in hospital-provided constrained medical services. A bubble chart of SDs for a specific month was generated to present the effects of using control charts in a national healthcare system. Results ICCs were generated for Taiwan’s year-based convergent power to constrain its medical services from 2000 to 2009. All hospital groups showed a gradually well-controlled supply of services that decreased from 0.772 to 0.415. The bubble chart identified outlier hospitals that required investigation of possible excessive reimbursements in a specific time period. Conclusion We recommend using the ICC to annually assess a nation’s year-based convergent power to constrain medical services across hospitals. Using sequential control charts to regularly monitor hospital reimbursements is required to achieve financial control in a single-payer nationwide healthcare system. PMID:22587736
Chien, Tsair-Wei; Chou, Ming-Ting; Wang, Wen-Chung; Tsai, Li-Shu; Lin, Weir-Sen
2012-05-15
Few studies discuss the indicators used to assess the effect on cost containment in healthcare across hospitals in a single-payer national healthcare system with constrained medical resources. We present the intraclass correlation coefficient (ICC) to assess how well Taiwan constrained hospital-provided medical services in such a system. A custom Excel-VBA routine to record the distances of standard deviations (SDs) from the central line (the mean over the previous 12 months) of a control chart was used to construct and scale annual medical expenditures sequentially from 2000 to 2009 for 421 hospitals in Taiwan to generate the ICC. The ICC was then used to evaluate Taiwan's year-based convergent power to remain unchanged in hospital-provided constrained medical services. A bubble chart of SDs for a specific month was generated to present the effects of using control charts in a national healthcare system. ICCs were generated for Taiwan's year-based convergent power to constrain its medical services from 2000 to 2009. All hospital groups showed a gradually well-controlled supply of services that decreased from 0.772 to 0.415. The bubble chart identified outlier hospitals that required investigation of possible excessive reimbursements in a specific time period. We recommend using the ICC to annually assess a nation's year-based convergent power to constrain medical services across hospitals. Using sequential control charts to regularly monitor hospital reimbursements is required to achieve financial control in a single-payer nationwide healthcare system.
Calculation of brain atrophy using computed tomography and a new atrophy measurement tool
NASA Astrophysics Data System (ADS)
Bin Zahid, Abdullah; Mikheev, Artem; Yang, Andrew Il; Samadani, Uzma; Rusinek, Henry
2015-03-01
Purpose: To determine if brain atrophy can be calculated by performing volumetric analysis on conventional computed tomography (CT) scans in spite of relatively low contrast for this modality. Materials & Method: CTs for 73 patients from the local Veteran Affairs database were selected. Exclusion criteria: AD, NPH, tumor, and alcohol abuse. Protocol: conventional clinical acquisition (Toshiba; helical, 120 kVp, X-ray tube current 300mA, slice thickness 3-5mm). Locally developed, automatic algorithm was used to segment intracranial cavity (ICC) using (a) white matter seed (b) constrained growth, limited by inner skull layer and (c) topological connectivity. ICC was further segmented into CSF and brain parenchyma using a threshold of 16 Hu. Results: Age distribution: 25-95yrs; (Mean 67+/-17.5yrs.). Significant correlation was found between age and CSF/ICC(r=0.695, p<0.01 2-tailed). A quadratic model (y=0.06-0.001x+2.56x10-5x2 ; where y=CSF/ICC and x=age) was a better fit to data (r=0.716, p < 0.01). This is in agreement with MRI literature. For example, Smith et al. found annual CSF/ICC increase in 58 - 94.5 y.o. individuals to be 0.2%/year, whereas our data, restricted to the same age group yield 0.3%/year(0.2-0.4%/yrs. 95%C.I.). Slightly increased atrophy among elderly VA patients is attributable to the presence of other comorbidities. Conclusion: Brain atrophy can be reliably calculated using automated software and conventional CT. Compared to MRI, CT is more widely available, cheaper, and less affected by head motion due to ~100 times shorter scan time. Work is in progress to improve the precision of the measurements, possibly leading to assessment of longitudinal changes within the patient.
Byun, Ha Young; Shin, Heesuk; Lee, Eun Shin; Kong, Min Sik; Lee, Seung Hun
2016-01-01
Objective To assess the intra-rater and inter-rater reliability for measuring femoral anteversion angle (FAA) by a radiographic method using three-dimensional computed tomography reconstruction (3D-CT). Methods The study included 82 children who presented with intoeing gait. 3D-CT data taken between 2006 and 2014 were retrospectively reviewed. FAA was measured by 3D-CT. FAA is defined as the angle between the long axis of the femur neck and condylar axis of the distal femur. FAA measurement was performed twice at both lower extremities by each rater. The intra-rater and inter-rater reliability were calculated by intraclass correlation coefficient (ICC). Results One hundred and sixty-four lower limbs of 82 children (31 boys and 51 girls, 6.3±3.2 years old) were included. The ICCs of intra-rater measurement for the angle of femoral neck axis (NA) were 0.89 for rater A and 0.96 for rater B, and those of condylar axis (CA) were 0.99 for rater A and 0.99 for rater B, respectively. The ICC of inter-rater measurement for the angle of NA was 0.89 and that of CA was 0.92. By each rater, the ICCs of the intrarater measurement for FAA were 0.97 for rater A and 0.95 for rater B, respectively and the ICC of the inter-rater measurement for FAA was 0.89. Conclusion The 3D-CT measures for FAA are reliable within individual raters and between different raters. The 3D-CT measures of FAA can be a useful method for accurate diagnosis and follow-up of femoral anteversion. PMID:27152273
Zhang, Guoshan; Xie, Shen; Hu, Wei; Liu, Yuer; Liu, Mailan; Liu, Mi; Chang, Xiaorong
2016-06-14
BACKGROUND Gastrointestinal motility disorder is the main clinical manifestation in functional dyspepsia (FD) patients. Electroacupuncture is effective in improving gastrointestinal motility disorder in FD; however, the underlying mechanism remains unclear. It has been demonstrated that interstitial cells of Cajal (ICC) are pacemaker cells in the gastrointestinal tract, and the pacemaker potential is transmitted to nearby cells through gap junctions between ICC or ICC and the smooth muscle. Therefore, this study aimed to assess the effects of electroacupuncture on ICC ultrastructure and expression of the gap junction protein connexin 43 (Cx43) in FD rats. MATERIAL AND METHODS The animals were randomized into 3 groups: control, model, and electroacupuncture. Electroacupuncture was applied at Zusanli (ST36) in the electroacupuncture group daily for 10 days, while no electroacupuncture was applied to model group animals. RESULTS Ultrastructure of ICC recovered normally in gastric antrum and small intestine specimens was improved, with Cx43 expression levels in these tissues significantly increased in the electroacupuncture group compared with the model group. CONCLUSIONS These findings indicated that electroacupuncture is effective in alleviating ICC damage and reduces Cx43 levels in FD rats, and suggest that ICC and Cx43 are involved in electroacupuncture treatment in rats with FD to improve gastrointestinal motility disorders.
Groth, M; Forkert, N D; Buhk, J H; Schoenfeld, M; Goebell, E; Fiehler, J
2013-02-01
To compare intra- and inter-observer reliability of aneurysm measurements obtained by a 3D computer-aided technique with standard manual aneurysm measurements in different imaging modalities. A total of 21 patients with 29 cerebral aneurysms were studied. All patients underwent digital subtraction angiography (DSA), contrast-enhanced (CE-MRA) and time-of-flight magnetic resonance angiography (TOF-MRA). Aneurysm neck and depth diameters were manually measured by two observers in each modality. Additionally, semi-automatic computer-aided diameter measurements were performed using 3D vessel surface models derived from CE- (CE-com) and TOF-MRA (TOF-com) datasets. Bland-Altman analysis (BA) and intra-class correlation coefficient (ICC) were used to evaluate intra- and inter-observer agreement. BA revealed the narrowest relative limits of intra- and inter-observer agreement for aneurysm neck and depth diameters obtained by TOF-com (ranging between ±5.3 % and ±28.3 %) and CE-com (ranging between ±23.3 % and ±38.1 %). Direct measurements in DSA, TOF-MRA and CE-MRA showed considerably wider limits of agreement. The highest ICCs were observed for TOF-com and CE-com (ICC values, 0.92 or higher for intra- as well as inter-observer reliability). Computer-aided aneurysm measurement in 3D offers improved intra- and inter-observer reliability and a reproducible parameter extraction, which may be used in clinical routine and as objective surrogate end-points in clinical trials.
Meirte, J; Moortgat, P; Truijen, S; Maertens, K; Lafaire, C; De Cuyper, L; Hubens, G; Van Daele, U
2015-09-01
Burn scars are frequently accompanied with sensory deficits often remaining present months or even years after injury. Clinimetric properties of assessment tools remain understudied within burn literature. Tactile sense of touch can be examined with the touch pressure threshold (TPT) method using the Semmes Weinstein monofilament test (SWMT). There is in recent research no consensus on the exact measurement procedure when using the SWMT. The aim of this paper was to determine the interrater and intrarater reliability of TPT within burn scars and healthy controls using the 'ascending descending' measurement procedure. We used the newly developed guidelines for reporting reliability and agreement studies (GRRAS) as a basis to report this reliability study. In total 36 individuals were tested; a healthy control group and a scar group. The interrater reliability was excellent in the scar group (ICC=0.908/SEM=0.21) and fair to good in the control group (ICC=0.731/SEM=0.12). In the scar group intrarater ICC value was excellent (ICC=0.822/SEM=0.33). Within the control group also an excellent intrarater reliability (ICC=0.807/SEM=0.27) was found. In conclusion this study shows that the SWMT with the 'ascending descending' measurement procedure is a feasible and reliable objective measure to evaluate TPT in (older) upper extremities burn scars as well as in healthy skin. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.
Negotiating Decisions during Informed Consent for Pediatric Phase I Oncology Trials
Marshall, Patricia A.; Magtanong, Ruth V.; Leek, Angela C.; Hizlan, Sabahat; Yamokoski, Amy D.; Kodish, Eric D.
2012-01-01
During informed consent conferences (ICCs) for Phase I trials, oncologists must present complex information while addressing concerns. Research on communication that evolves during ICCs remains largely unexplored. We examined communication during ICCs for pediatric Phase I cancer trials using a stratified random sample from six pediatric cancer centers. A grounded theory approach identified key communication steps and factors influencing the negotiation of decisions for trial participation. Analysis suggests that during ICCs, families, patients, and clinicians exercise choice and control by negotiating micro-decisions in two broad domains: drug logic and logistics, and administration/scheduling. Micro-decisions unfold in a four-step communication process: (1) introduction of an issue; (2) response; (3) negotiation of the issue; and (4) resolution and decision. Negotiation over smaller micro-decisions is prominent in ICCs and merits further study. PMID:22565583
Negotiating decisions during informed consent for pediatric Phase I oncology trials.
Marshall, Patricia A; Magtanong, Ruth V; Leek, Angela C; Hizlan, Sabahat; Yamokoski, Amy D; Kodish, Eric D
2012-04-01
During informed consent conferences (ICCs) for Phase I trials, oncologists must present complex information while addressing concerns. Research on communication that evolves during ICCs remains largely unexplored. We examined communication during ICCs for pediatric Phase I cancer trials using a stratified random sample from six pediatric cancer centers. A grounded theory approach identified key communication steps and factors influencing the negotiation of decisions for trial participation. Analysis suggests that during ICCs, families, patients, and clinicians exercise choice and control by negotiating micro-decisions in two broad domains: drug logic and logistics, and administration/scheduling. Micro-decisions unfold in a four-step communication process: (1) introduction of an issue; (2) response; (3) negotiation of the issue; and (4) resolution and decision. Negotiation over smaller micro-decisions is prominent in ICCs and merits further study.
Comparison of Automated Brain Volume Measures obtained with NeuroQuant and FreeSurfer.
Ochs, Alfred L; Ross, David E; Zannoni, Megan D; Abildskov, Tracy J; Bigler, Erin D
2015-01-01
To examine intermethod reliabilities and differences between FreeSurfer and the FDA-cleared congener, NeuroQuant, both fully automated methods for structural brain MRI measurements. MRI scans from 20 normal control subjects, 20 Alzheimer's disease patients, and 20 mild traumatically brain-injured patients were analyzed with NeuroQuant and with FreeSurfer. Intermethod reliability was evaluated. Pairwise correlation coefficients, intraclass correlation coefficients, and effect size differences were computed. NeuroQuant versus FreeSurfer measures showed excellent to good intermethod reliability for the 21 regions evaluated (r: .63 to .99/ICC: .62 to .99/ES: -.33 to 2.08) except for the pallidum (r/ICC/ES = .31/.29/-2.2) and cerebellar white matter (r/ICC/ES = .31/.31/.08). Volumes reported by NeuroQuant were generally larger than those reported by FreeSurfer with the whole brain parenchyma volume reported by NeuroQuant 6.50% larger than the volume reported by FreeSurfer. There was no systematic difference in results between the 3 subgroups. NeuroQuant and FreeSurfer showed good to excellent intermethod reliability in volumetric measurements for all brain regions examined with the only exceptions being the pallidum and cerebellar white matter. This finding was robust for normal individuals, patients with Alzheimer's disease, and patients with mild traumatic brain injury. Copyright © 2015 by the American Society of Neuroimaging.
Molecular Mapping of Flowering Time Major Genes and QTLs in Chickpea (Cicer arietinum L.)
Mallikarjuna, Bingi P.; Samineni, Srinivasan; Thudi, Mahendar; Sajja, Sobhan B.; Khan, Aamir W.; Patil, Ayyanagowda; Viswanatha, Kannalli P.; Varshney, Rajeev K.; Gaur, Pooran M.
2017-01-01
Flowering time is an important trait for adaptation and productivity of chickpea in the arid and the semi-arid environments. This study was conducted for molecular mapping of genes/quantitative trait loci (QTLs) controlling flowering time in chickpea using F2 populations derived from four crosses (ICCV 96029 × CDC Frontier, ICC 5810 × CDC Frontier, BGD 132 × CDC Frontier and ICC 16641 × CDC Frontier). Genetic studies revealed monogenic control of flowering time in the crosses ICCV 96029 × CDC Frontier, BGD 132 × CDC Frontier and ICC 16641 × CDC Frontier, while digenic control with complementary gene action in ICC 5810 × CDC Frontier. The intraspecific genetic maps developed from these crosses consisted 75, 75, 68 and 67 markers spanning 248.8 cM, 331.4 cM, 311.1 cM and 385.1 cM, respectively. A consensus map spanning 363.8 cM with 109 loci was constructed by integrating four genetic maps. Major QTLs corresponding to flowering time genes efl-1 from ICCV 96029, efl-3 from BGD 132 and efl-4 from ICC 16641 were mapped on CaLG04, CaLG08 and CaLG06, respectively. The QTLs and linked markers identified in this study can be used in marker-assisted breeding for developing early maturing chickpea. PMID:28729871
Intra- and interobserver agreement for fetal cerebral measurements in 3D-ultrasonography.
Albers, Maria E W A; Buisman, Erato T I A; Kahn, René S; Franx, Arie; Onland-Moret, N Charlotte; de Heus, Roel
2018-04-10
The aim of this study is to evaluate intra- and interobserver agreement for measurement of intracranial, cerebellar, and thalamic volume with the Virtual Organ Computer-aided AnaLysis (VOCAL) technique in three-dimensional ultrasound images, in comparison to two-dimensional measurements of these brain structures. Three-dimensional ultrasound images of the brains of 80 fetuses at 20-24 weeks' gestational age were obtained from YOUth, a Dutch prospective cohort study. Two observers performed offline measurement of the occipitofrontal diameter, intracranial volume, transcerebellar diameter, cerebellar volume, and thalamic width, area, and volume, independently. VOCAL was used for calculation of the volumes. The two-way random, single measures intraclass correlation coefficient (ICC) was used for analysis of agreement and Bland-Altman plots were configured. Intra- and interobserver agreement was almost perfect for occipitofrontal diameter (intra ICC 0.88, 95% CI 0.82-0.92; inter ICC 0.91, 95% CI 0.85-0.94), intracranial volume (intra ICC 0.96, 95% CI 0.91-0.98; inter ICC 0.97, 95% CI 0.96-0.98) and transcerebellar diameter (intra ICC 0.91, 95% CI 0.86-0.94; inter ICC 0.86, 95% CI 0.78-0.910). For cerebellar volume, the intraobserver agreement was almost perfect (0.85, 95% CI 0.76-0.90), whereas the interobserver agreement was substantial (0.75, 95% CI 0.44-0.88). Agreement was only moderate for thalamic measurements. Bland-Altman plots for the volume measurements are normally distributed with acceptable mean differences and 95% limits of agreement. The intra- and interobserver agreement of the measurement of intracranial and cerebellar volume with VOCAL was almost perfect. These measurements are therefore reliable, and can be used to investigate fetal brain development. Thalamic measurements are not reliable enough. © 2018 Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
Luck, R.; Ray, A.
1988-01-01
A method for compensating the effects of network-induced delays in integrated communication and control systems (ICCS) is proposed, and a finite-dimensional time-invariant ICCS model is developed. The problem of analyzing systems with time-varying and stochastic delays is circumvented by the application of a deterministic observer. For the case of controller-to-actuator delays, the observed design must rely on an extended model which represents the delays as additional states.
Zhang, Guoshan; Xie, Shen; Hu, Wei; Liu, Yuer; Liu, Mailan; Liu, Mi; Chang, Xiaorong
2016-01-01
Background Gastrointestinal motility disorder is the main clinical manifestation in functional dyspepsia (FD) patients. Electroacupuncture is effective in improving gastrointestinal motility disorder in FD; however, the underlying mechanism remains unclear. It has been demonstrated that interstitial cells of Cajal (ICC) are pacemaker cells in the gastrointestinal tract, and the pacemaker potential is transmitted to nearby cells through gap junctions between ICC or ICC and the smooth muscle. Therefore, this study aimed to assess the effects of electroacupuncture on ICC ultrastructure and expression of the gap junction protein connexin 43 (Cx43) in FD rats. Material/Methods The animals were randomized into 3 groups: control, model, and electroacupuncture. Electroacupuncture was applied at Zusanli (ST36) in the electroacupuncture group daily for 10 days, while no electroacupuncture was applied to model group animals. Results Ultrastructure of ICC recovered normally in gastric antrum and small intestine specimens was improved, with Cx43 expression levels in these tissues significantly increased in the electroacupuncture group compared with the model group. Conclusions These findings indicated that electroacupuncture is effective in alleviating ICC damage and reduces Cx43 levels in FD rats, and suggest that ICC and Cx43 are involved in electroacupuncture treatment in rats with FD to improve gastrointestinal motility disorders. PMID:27297942
Midrio, P; Faussone-Pellegrini, M S; Vannucchi, M G; Flake, A W
2004-10-01
A pacemaker system is required for peristalsis generation. The interstitial cells of Cajal (ICC) are considered the intestinal pacemaker, and are identified by expression of the c-kit gene--encoded protein. Gastroschisis is characterized by a severe gastrointestinal dysmotility in newborns. In spite of this clinical picture, few studies have focused on smooth muscle cells (SMC) morphology and none on ICC. Therefore, their morphology has been studied in fetuses at term in the rat model of gastroschisis. At 18.5 day's gestation (E18.5), 10 rat fetuses were killed, 10 underwent surgical creation of gastroschisis, and 10 underwent manipulation only. The small intestine of the latter 2 groups was harvested at E21.5. Specimens were processed for H&E, c-kit and actin (alpha smooth muscle antibody [alpha-SMA]) immunohistochemistry, and transmission electron microscopy (TEM). In the controls, SMC were c-kit+ and alpha-SMA+, with labeling intensity increasing by age. At E21.5, some cells around the Auerbach's plexus were more intensely c-kit+, and differentiating ICC were seen under TEM at this level. Gastroschisis fetuses had no c-kit+ cells referable to ICC. In the more damaged loops, SMC were very faintly c-kit+ and alpha-SMA+. Under TEM, there were few differentiated SMC and no presumptive ICC. In the less-damaged loops, SMC were faintly c-kit+ and alpha-SMA+ and had ultrastructural features intermediate between those of E18.5 and E21.5 controls; ICC were very immature. ICC and SMC differentiation is delayed in gastroschisis with the most damaged loops showing the most incomplete picture. These findings might help in understanding the delayed onset of peristalsis and the variable time-course of the recover seen in babies affected by gastroschisis.
Figueroa, José; Guarachi, Juan Pablo; Matas, José; Arnander, Magnus; Orrego, Mario
2016-04-01
Computed tomography (CT) is widely used to assess component rotation in patients with poor results after total knee arthroplasty (TKA). The purpose of this study was to simultaneously determine the accuracy and reliability of CT in measuring TKA component rotation. TKA components were implanted in dry-bone models and assigned to two groups. The first group (n = 7) had variable femoral component rotations, and the second group (n = 6) had variable tibial tray rotations. CT images were then used to assess component rotation. Accuracy of CT rotational assessment was determined by mean difference, in degrees, between implanted component rotation and CT-measured rotation. Intraclass correlation coefficient (ICC) was applied to determine intra-observer and inter-observer reliability. Femoral component accuracy showed a mean difference of 2.5° and the tibial tray a mean difference of 3.2°. There was good intra- and inter-observer reliability for both components, with a femoral ICC of 0.8 and 0.76, and tibial ICC of 0.68 and 0.65, respectively. CT rotational assessment accuracy can differ from true component rotation by approximately 3° for each component. It does, however, have good inter- and intra-observer reliability.
Integrated communication and control systems. I - Analysis
NASA Technical Reports Server (NTRS)
Halevi, Yoram; Ray, Asok
1988-01-01
The paper presents the results of an ICCS analysis focusing on discrete-time control systems subject to time-varying delays. The present analytical technique is applicable to integrated dynamic systems such as those encountered in advanced aircraft, spacecraft, and the real-time control of robots and machine tools via a high-speed network within an autonomous manufacturing environment. The significance of data latency and missynchronization between individual system components in ICCS networks is discussed in view of the time-varying delays.
Staging of intrahepatic cholangiocarcinoma
Ronnekleiv-Kelly, Sean M.
2017-01-01
Intrahepatic cholangiocarcinoma (ICC) comprises approximately 5−30% of primary liver tumors, however it has been increasing over the last several decades. Up to and including the 6th edition of the American Joint Committee on Cancer/Union for International Cancer Control (AJCC/UICC) edition staging system, ICC was staged the same as hepatocellular carcinoma. In the 7th edition AJCC/UICC manual, the staging system of ICC was revised such that a distinct classification was proposed. Pathologic features for prognosis included vascular invasion, tumor multiplicity, local extension, periductal infiltration and lymph nodal metastasis. Over the last decade, as the incidence of ICC has increased and surgery for this indication has become more common, more data has been published on the prognostic factors associated with long-term survival. PMID:28261593
Potential safety benefits of intelligent cruise control systems.
Chira-Chavala, T; Yoo, S M
1994-04-01
Potential safety impact of a hypothetical intelligent cruise control system (ICCS) is evaluated in terms of changes in traffic accidents and some traffic operation characteristics affecting safety. The analysis of changes in traffic accidents is accomplished by in-depth examinations of police accident reports for four major counties in California. The evaluation of changes in traffic operation characteristics affecting safety is accomplished by vehicle simulation. The accident analysis reveals that the use of the hypothetical ICCS could potentially reduce traffic accidents by up to 7.5%. Preliminary vehicle simulation results based on a 10-vehicle convoy indicate that the use of the hypothetical ICCS could reduce frequencies of hard acceleration and deceleration, enhance speed harmonization among vehicles, and reduce incidence of "less-safe" headway.
Paraspinal skin temperature patterns: an interexaminer and intraexaminer reliability study.
Owens, Edward F; Hart, John F; Donofrio, Joseph J; Haralambous, Jason; Mierzejewski, Eric
2004-01-01
Paraspinal thermography is used by chiropractors as an aid in assessing the presence of vertebral subluxation. Few reliability studies have been carried out, with mixed results. Digital infrared scanning equipment is now available with location tracking that may enhance reproducibility. Digitized scans enable a computer-aided interpretation of thermographic patterns. To assess the ability of examiners to reproduce thermal patterns. Repeated measures with 2 examiners assessing the same patient on 2 occasions. Thirty asymptomatic students served as subjects. A TyTron C-3000 handheld thermographic scanner interfaced to a Microsoft Windows compatible personal computer was used for all recordings. Each examiner recorded 2 scans on each patient. It took an average of 3 minutes to complete all 4 scans. Data were exported to a spreadsheet for initial analysis, then SPSS was used for calculation of intraclass correlation coefficients (ICC). Since the starting and stopping points of scans were not always the same, care was taken to align scans visually, using well-distinguished peaks on the charts as guides. Scans were cropped to remove artifacts that might have occurred at the beginning and end of the scans. Intraexaminer and interexaminer ICCs were calculated. Skin temperatures ranged from 35.4 degrees C to 30.0 degrees C over all scans. The average temperatures changed little from the first to the last scans, indicating that subjects' overall skin temperatures were stable during the scanning procedure. Intraexaminer ICCs ranged from 0.953 to 0.984. The left and right channel data show slightly higher congruence than the Delta channel. The interexaminer reliability coefficients ranged from 0.918 to 0.975. Again, the Delta channel shows slightly less reliability, although the ICCs were quite high for all channels. Intraexaminer and interexaminer reliability of paraspinal thermal scans using the TyTron C-3000 were found to be very high, with ICC values between 0.91 and 0.98. Changes seen in thermal scans when properly done are most likely due to actual physiological changes rather than equipment error.
Hamano, Genya; Kubo, Shoji; Takemura, Shigekazu; Tanaka, Shogo; Shinkawa, Hiroji; Kinoshita, Masahiko; Ito, Tokuji; Yamamoto, Takatsugu; Wakasa, Kenichi; Shibata, Toshihiko
2016-07-01
An outbreak of cholangiocarcinoma has been reported among workers of an offset color proof-printing department at a printing company in Japan. In this study, we compared the clinicopathological findings of this type of intrahepatic cholangiocarcinoma (occupational ICC) and non-occupational ICC. The clinical records of 51 patients with perihilar-type ICC who underwent liver resection, including five patients with occupational ICC were retrospectively reviewed. The clinicopathological features were compared. In the occupational group, the patients were significantly younger (P < 0.01), while serum γ-glutamyl transpeptidase activity and the proportions of patients with regional dilatation of the bile ducts without tumor-induced obstruction were significantly higher (P = 0.041 and P < 0.01, respectively); the indocyanine green retention rate at 15 min was significantly lower (P = 0.020). On pathological examinations, precancerous or early cancerous lesions, such as biliary intraepithelial neoplasia and intraductal papillary neoplasm of the bile duct, were observed at various sites of the bile ducts in all occupational ICC patients; such lesions were observed in only six patients in the control group (P < 0.01). The clinicopathological findings including age, liver function test results, diagnostic imaging findings, and pathological findings differed between the occupational and control groups. © 2016 Japanese Society of Hepato-Biliary-Pancreatic Surgery.
Klymiuk, Nikolai; van Buerck, Lelia; Bähr, Andrea; Offers, Monika; Kessler, Barbara; Wuensch, Annegret; Kurome, Mayuko; Thormann, Michael; Lochner, Katharina; Nagashima, Hiroshi; Herbach, Nadja; Wanke, Rüdiger; Seissler, Jochen; Wolf, Eckhard
2012-06-01
Islet transplantation is a potential treatment for type 1 diabetes, but the shortage of donor organs limits its routine application. As potential donor animals, we generated transgenic pigs expressing LEA29Y, a high-affinity variant of the T-cell costimulation inhibitor CTLA-4Ig, under the control of the porcine insulin gene promoter. Neonatal islet cell clusters (ICCs) from INSLEA29Y transgenic (LEA-tg) pigs and wild-type controls were transplanted into streptozotocin-induced hyperglycemic NOD-scid IL2Rγ(null) mice. Cloned LEA-tg pigs are healthy and exhibit a strong β-cell-specific transgene expression. LEA-tg ICCs displayed the same potential to normalize glucose homeostasis as wild-type ICCs after transplantation. After adoptive transfer of human peripheral blood mononuclear cells, transplanted LEA-tg ICCs were completely protected from rejection, whereas reoccurrence of hyperglycemia was observed in 80% of mice transplanted with wild-type ICCs. In the current study, we provide the first proof-of-principle report on transgenic pigs with β-cell-specific expression of LEA29Y and their successful application as donors in a xenotransplantation model. This approach may represent a major step toward the development of a novel strategy for pig-to-human islet transplantation without side effects of systemic immunosuppression.
Roura, Esther; Travier, Noémie; Waterboer, Tim; de Sanjosé, Silvia; Bosch, F. Xavier; Pawlita, Michael; Pala, Valeria; Weiderpass, Elisabete; Margall, Núria; Dillner, Joakim; Gram, Inger T.; Tjønneland, Anne; Munk, Christian; Palli, Domenico; Khaw, Kay-Tee; Overvad, Kim; Clavel-Chapelon, Françoise; Mesrine, Sylvie; Fournier, Agnès; Fortner, Renée T.; Ose, Jennifer; Steffen, Annika; Trichopoulou, Antonia; Lagiou, Pagona; Orfanos, Philippos; Masala, Giovanna; Tumino, Rosario; Sacerdote, Carlotta; Polidoro, Silvia; Mattiello, Amalia; Lund, Eiliv; Peeters, Petra H.; Bueno-de-Mesquita, H. B(as).; Quirós, J. Ramón; Sánchez, María-José; Navarro, Carmen; Barricarte, Aurelio; Larrañaga, Nerea; Ekström, Johanna; Lindquist, David; Idahl, Annika; Travis, Ruth C.; Merritt, Melissa A.; Gunter, Marc J.; Rinaldi, Sabina; Tommasino, Massimo; Franceschi, Silvia; Riboli, Elio; Castellsagué, Xavier
2016-01-01
Background In addition to HPV, high parity and hormonal contraceptives have been associated with cervical cancer (CC). However, most of the evidence comes from retrospective case-control studies. The aim of this study is to prospectively evaluate associations between hormonal factors and risk of developing cervical intraepithelial neoplasia grade 3 (CIN3)/carcinoma in situ (CIS) and invasive cervical cancer (ICC). Methods and Findings We followed a cohort of 308,036 women recruited in the European Prospective Investigation into Cancer and Nutrition (EPIC) Study. At enrollment, participants completed a questionnaire and provided serum. After a 9-year median follow-up, 261 ICC and 804 CIN3/CIS cases were reported. In a nested case-control study, the sera from 609 cases and 1,218 matched controls were tested for L1 antibodies against HPV types 11,16,18,31,33,35,45,52,58, and antibodies against Chlamydia trachomatis and Human herpesvirus 2. Multivariate analyses were performed to estimate hazard ratios (HR), odds ratios (OR) and corresponding 95% confidence intervals (CI). The cohort analysis showed that number of full-term pregnancies was positively associated with CIN3/CIS risk (p-trend = 0.03). Duration of oral contraceptives use was associated with a significantly increased risk of both CIN3/CIS and ICC (HR = 1.6 and HR = 1.8 respectively for ≥15 years versus never use). Ever use of menopausal hormone therapy was associated with a reduced risk of ICC (HR = 0.5, 95%CI: 0.4–0.8). A non-significant reduced risk of ICC with ever use of intrauterine devices (IUD) was found in the nested case-control analysis (OR = 0.6). Analyses restricted to all cases and HPV seropositive controls yielded similar results, revealing a significant inverse association with IUD for combined CIN3/CIS and ICC (OR = 0.7). Conclusions Even though HPV is the necessary cause of CC, our results suggest that several hormonal factors are risk factors for cervical carcinogenesis. Adherence to current cervical cancer screening guidelines should minimize the increased risk of CC associated with these hormonal risk factors. PMID:26808155
Utility of computer-assisted approaches for population surveillance of physical activity.
Creamer, MeLisa; Bowles, Heather R; von Hofe, Belinda; Pettee Gabriel, Kelley; Kohl, Harold W; Bauman, Adrian
2014-08-01
Computer-assisted techniques may be a useful way to enhance physical activity surveillance and increase accuracy of reported behaviors. Evaluate the reliability and validity of a physical activity (PA) self-report instrument administered by telephone and internet. The telephone-administered Active Australia Survey was adapted into 2 forms for internet self-administration: survey questions only (internet-text) and with videos demonstrating intensity (internet-video). Data were collected from 158 adults (20-69 years, 61% female) assigned to telephone (telephone-interview) (n = 56), internet-text (n = 51), or internet-video (n = 51). Participants wore an accelerometer and completed a logbook for 7 days. Test-retest reliability was assessed using intraclass correlation coefficients (ICC). Convergent validity was assessed using Spearman correlations. Strong test-retest reliability was observed for PA variables in the internet-text (ICC = 0.69 to 0.88), internet-video (ICC = 0.66 to 0.79), and telephone-interview (ICC = 0.69 to 0.92) groups (P-values < 0.001). For total PA, correlations (ρ) between the survey and Actigraph+logbook were ρ = 0.47 for the internet-text group, ρ = 0.57 for the internet-video group, and ρ = 0.65 for the telephone-interview group. For vigorous-intensity activity, the correlations between the survey and Actigraph+logbook were 0.52 for internet-text, 0.57 for internet-video, and 0.65 for telephone-interview (P < .05). Internet-video of the survey had similar test-retest reliability and convergent validity when compared with the telephone-interview, and should continue to be developed.
Zhang, R-X; Wang, X-Y; Chen, D; Huizinga, J D
2011-09-01
Interstitial cells of Cajal (ICC) are intimately linked to the enteric nervous system and a better understanding of the interactions between the two systems is going to advance our understanding of gut motor control. The objective of the present study was to investigate the role of ICC in the generation of gastric motor activity induced by cholinergic neurotransmission. Gastric motor activity was evoked through activation of intrinsic cholinergic neural activity, in in vitro muscle strips by electrical field stimulation, in the in vitro whole stomach by distension and in vivo by fluoroscopy after gavaging the stomach with barium sulfate. The cholinergic activity was assessed as that component of the effect of the stimulus that was sensitive to atropine. These experiments were carried out in wild-type and Ws/Ws rats that have few intramuscular ICC (ICC-IM) in the stomach. Under all three experimental conditions, cholinergic activity was prominent in both wild-type and W mutant rats providing evidence against the hypothesis that cholinergic neurotransmission to smooth muscle is primarily mediated by ICC-IM. Strong cholinergic activity in Ws/Ws rats was not due to upregulation of muscarinic receptors in ICC but possibly in smooth muscle of the antrum. Pacemaker ICC play a prominent role in the expression of motor activity induced by cholinergic activity and our data suggest that cholinergic neurotransmission to ICC affects the pacemaker frequency. © 2011 Blackwell Publishing Ltd.
Architecture and Programming Models for High Performance Intensive Computation
2016-06-29
Applications Systems and Large-Scale-Big-Data & Large-Scale-Big-Computing (DDDAS- LS ). ICCS 2015, June 2015. Reykjavk, Ice- land. 2. Bo YT, Wang P, Guo ZL...The Mahali project,” Communications Magazine , vol. 52, pp. 111–133, Aug 2014. 14 DISTRIBUTION A: Distribution approved for public release. Response ID
A Model Code of Ethics for the Use of Computers in Education.
ERIC Educational Resources Information Center
Shere, Daniel T.; Cannings, Terence R.
Two Delphi studies were conducted by the Ethics and Equity Committee of the International Council for Computers in Education (ICCE) to obtain the opinions of experts on areas that should be covered by ethical guides for the use of computers in education and for software development, and to develop a model code of ethics for each of these areas.…
Test-Retest Reliability and Practice Effects of the Stability Evaluation Test.
Williams, Richelle M; Corvo, Matthew A; Lam, Kenneth C; Williams, Travis A; Gilmer, Lesley K; McLeod, Tamara C Valovich
2017-01-17
Postural control plays an essential role in concussion evaluation. The Stability Evaluation Test (SET) aims to objectively analyze postural control by measuring sway velocity on the NeuroCom's VSR portable force platform (Natus, San Carlos, CA). To assess the test-retest reliability and practice effects of the SET protocol. Cohort. Research Laboratory. Fifty healthy adults (males=20, females=30, age=25.30±3.60 years, height=166.60±12.80 cm, mass=68.80±13.90 kg). All participants completed four trials of the SET. Each trial consisted of six 20-second balance tests with eyes closed, under the following conditions: double-leg firm (DFi), single-leg firm (SFi), tandem firm (TFi), double-leg foam (DFo), single-leg foam (SFo), and tandem foam (TFo). Each trial was separated by a 5-minute seated rest period. The dependent variable was sway velocity (deg/sec), with lower values indicating better balance. Sway velocity was recorded for each of the six conditions as well as a composite score for each trial. Test-retest reliability was analyzed across four trials with Intraclass Correlation Coefficients. Practice effects analyzed with repeated measures analysis of variance, followed by Tukey post-hoc comparisons for any significant main effects (p<.05). Sway velocity reliability values were good to excellent: DFi (ICC=0.88;95%CI:0.81,0.92), SFi (ICC=0.75;95%CI:0.61,0.85), TFi (ICC=0.84;95%CI:0.75,0.90), DFo (ICC=0.83;95%CI:0.74,0.90), SFo (ICC=0.82;95%CI:0.72,0.89), TFo (ICC=0.81;95%CI:0.69,0.88), and composite score (ICC=0.93;95%CI:0.88,0.95). Significant practice effects (p<.05) were noted on the SFi, DFo, SFo, TFo conditions, and composite scores. Our results suggest the SET has good to excellent reliability for the assessment of postural control in healthy adults. Due to the practice effects noted, a familiarization session is recommended (i.e., all 6 conditions) prior to recording the data. Future studies should evaluate injured patients to determine meaningful change scores during various injuries.
van Vugt, Jeroen L A; Levolger, Stef; Gharbharan, Arvind; Koek, Marcel; Niessen, Wiro J; Burger, Jacobus W A; Willemsen, Sten P; de Bruin, Ron W F; IJzermans, Jan N M
2017-04-01
The association between body composition (e.g. sarcopenia or visceral obesity) and treatment outcomes, such as survival, using single-slice computed tomography (CT)-based measurements has recently been studied in various patient groups. These studies have been conducted with different software programmes, each with their specific characteristics, of which the inter-observer, intra-observer, and inter-software correlation are unknown. Therefore, a comparative study was performed. Fifty abdominal CT scans were randomly selected from 50 different patients and independently assessed by two observers. Cross-sectional muscle area (CSMA, i.e. rectus abdominis, oblique and transverse abdominal muscles, paraspinal muscles, and the psoas muscle), visceral adipose tissue area (VAT), and subcutaneous adipose tissue area (SAT) were segmented by using standard Hounsfield unit ranges and computed for regions of interest. The inter-software, intra-observer, and inter-observer agreement for CSMA, VAT, and SAT measurements using FatSeg, OsiriX, ImageJ, and sliceOmatic were calculated using intra-class correlation coefficients (ICCs) and Bland-Altman analyses. Cohen's κ was calculated for the agreement of sarcopenia and visceral obesity assessment. The Jaccard similarity coefficient was used to compare the similarity and diversity of measurements. Bland-Altman analyses and ICC indicated that the CSMA, VAT, and SAT measurements between the different software programmes were highly comparable (ICC 0.979-1.000, P < 0.001). All programmes adequately distinguished between the presence or absence of sarcopenia (κ = 0.88-0.96 for one observer and all κ = 1.00 for all comparisons of the other observer) and visceral obesity (all κ = 1.00). Furthermore, excellent intra-observer (ICC 0.999-1.000, P < 0.001) and inter-observer (ICC 0.998-0.999, P < 0.001) agreement for all software programmes were found. Accordingly, excellent Jaccard similarity coefficients were found for all comparisons (mean ≥ 0.964). FatSeg, OsiriX, ImageJ, and sliceOmatic showed an excellent agreement for CSMA, VAT, and SAT measurements on abdominal CT scans. Furthermore, excellent inter-observer and intra-observer agreement were achieved. Therefore, results of studies using these different software programmes can reliably be compared. © 2016 The Authors. Journal of Cachexia, Sarcopenia and Muscle published by John Wiley & Sons Ltd on behalf of the Society on Sarcopenia, Cachexia and Wasting Disorders.
Levolger, Stef; Gharbharan, Arvind; Koek, Marcel; Niessen, Wiro J.; Burger, Jacobus W.A.; Willemsen, Sten P.; de Bruin, Ron W.F.
2016-01-01
Abstract Background The association between body composition (e.g. sarcopenia or visceral obesity) and treatment outcomes, such as survival, using single‐slice computed tomography (CT)‐based measurements has recently been studied in various patient groups. These studies have been conducted with different software programmes, each with their specific characteristics, of which the inter‐observer, intra‐observer, and inter‐software correlation are unknown. Therefore, a comparative study was performed. Methods Fifty abdominal CT scans were randomly selected from 50 different patients and independently assessed by two observers. Cross‐sectional muscle area (CSMA, i.e. rectus abdominis, oblique and transverse abdominal muscles, paraspinal muscles, and the psoas muscle), visceral adipose tissue area (VAT), and subcutaneous adipose tissue area (SAT) were segmented by using standard Hounsfield unit ranges and computed for regions of interest. The inter‐software, intra‐observer, and inter‐observer agreement for CSMA, VAT, and SAT measurements using FatSeg, OsiriX, ImageJ, and sliceOmatic were calculated using intra‐class correlation coefficients (ICCs) and Bland–Altman analyses. Cohen's κ was calculated for the agreement of sarcopenia and visceral obesity assessment. The Jaccard similarity coefficient was used to compare the similarity and diversity of measurements. Results Bland–Altman analyses and ICC indicated that the CSMA, VAT, and SAT measurements between the different software programmes were highly comparable (ICC 0.979–1.000, P < 0.001). All programmes adequately distinguished between the presence or absence of sarcopenia (κ = 0.88–0.96 for one observer and all κ = 1.00 for all comparisons of the other observer) and visceral obesity (all κ = 1.00). Furthermore, excellent intra‐observer (ICC 0.999–1.000, P < 0.001) and inter‐observer (ICC 0.998–0.999, P < 0.001) agreement for all software programmes were found. Accordingly, excellent Jaccard similarity coefficients were found for all comparisons (mean ≥ 0.964). Conclusions FatSeg, OsiriX, ImageJ, and sliceOmatic showed an excellent agreement for CSMA, VAT, and SAT measurements on abdominal CT scans. Furthermore, excellent inter‐observer and intra‐observer agreement were achieved. Therefore, results of studies using these different software programmes can reliably be compared. PMID:27897414
Miao, Bin; Zhang, Shuwen; Wang, Hong; Yang, Tiecheng; Zhou, Deshan; Wang, Bao-en
2013-08-01
The purpose of this study was to investigate the mechanism by which magnolol treatment prevents lipopolysaccharide (LPS)-induced septic dysmotility in mice. Sepsis was induced by intravenous tail vein injection of LPS (4 mg/kg body weight). Animals were divided into three groups: the magnolol-treated septic group, the placebo-treated septic group, and the control group. Intestinal transit and circular smooth muscle contraction were measured 12 h after LPS injection, and immunocytochemisty was performed to study the morphology of interstitial cells of Cajal (ICCs). Stem cell factor (SCF) expression and c-kit phosphorylation were determined by Western blot analysis, and the mRNA levels of inducible NO synthase (iNOS) were determined by RT-PCR. Nitric oxide (NO) content, superoxide dismutase (SOD) activity, and malondialdehyde (MDA) concentration were detected using commercial kits. Intestinal transit and muscular contractility were significantly lower in the LPS-treated group than in the control group. Immunocytochemical experiments showed that the total number of ICCs, and the total and average lengths of the ICC processes were significantly decreased in the LPS-treated group compared with those in the control group. In LPS-treated animals, magnolol pretreatment significantly accelerated intestinal transit, increased circular muscle contraction, and prevented ICC morphology changes. Phosphorylation of c-kit and expression of SCF were significantly downregulated in LPS-treated animals compared with control animals. Magnolol pretreatment prevented sepsis-induced decreases in c-kit phosphorylation and SCF expression in LPS-treated animals. Magnolol pretreatment prevented the sepsis-induced increase in NO concentration, iNOS expression, and MDA concentration, and decrease in SOD activity in LPS-treated animals. Our results suggest that magnolol treatment prevents sepsis-induced intestinal dysmotility by regulating SCF/c-kit and NO signaling to maintain functional ICCs.
Fieseler, Georg; Molitor, Thomas; Irlenbusch, Lars; Delank, Karl-Stefan; Laudner, Kevin G; Hermassi, Souhail; Schwesig, Rene
2015-12-01
To evaluate the intrarater reliability for examining active range of motion (ROM) and isometric strength of the shoulder and elbow among asymptomatic female team handball athletes and a control group using a manual goniometer and hand-held dynamometry (HHD). 22 female team handball athletes (age: 21.0 ± 3.7 years) and 25 volunteers (13 female, 12 male, age: 21.9 ± 1.24 years) participated to determine bilateral ROM for shoulder rotation and elbow flexion/extension, as well as isometric shoulder rotation and elbow flexion/extension strength. Subjects were assessed on two separate test sessions with 7 days between sessions. Relative (intraclass correlation coefficients (ICC) and standard error of measurement (SEM) reliability were calculated. Reliability for ROM and strength were good to excellent for both shoulders and groups (athletes: ICC = 0.94-0.97, SEM 1.07°-4.76 N, controls: ICC = 0.96-1.00, SEM = 0.00 N-4.48 N). Elbow measurements for both groups also showed good-to-excellent reliability (athletes: ICC = 0.79-0.97, SEM = 0.98°-5.94 N, controls: ICC = 0.87-1.00, SEM = 0.00 N-5.43 N). It is important to be able to reliably reproduce active ROM and isometric strength evaluations. Using a standardized testing position, goniometry and HHD are reliable instruments in the assessment of shoulder and elbow joint performance testing. We showed good-to-excellent reproducible results for male and female control subjects and female handball athletes, although the single parameters in ROM and strength were different for each group and between the shoulders and elbows.
Glinatsi, Daniel; Bird, Paul; Gandjbakhch, Frederique; Mease, Philip J; Bøyesen, Pernille; Peterfy, Charles G; Conaghan, Philip G; Østergaard, Mikkel
2015-12-01
To assess changes following treatment and the reliability and responsiveness to change of the Outcome Measures in Rheumatology (OMERACT) Psoriatic Arthritis Magnetic Resonance Imaging Score (PsAMRIS) in a randomized controlled trial. Forty patients with PsA randomized to either placebo or abatacept (ABA) had MRI of either 1 hand (n = 20) or 1 foot (n = 20) at baseline and after 6 months. Images were scored blindly twice by 3 independent readers according to the PsAMRIS (for synovitis, tenosynovitis, periarticular inflammation, bone edema, bone erosion, and bone proliferation). Inflammatory features improved numerically but statistically nonsignificantly in the ABA group but not the placebo group. Baseline intrareader intraclass correlation coefficients (ICC) were good (≥ 0.50) to very good (≥ 0.80) for all features in both hand and foot. Baseline interreader ICC were good (ICC 0.72-0.96) for all features, except periarticular inflammation and bone proliferation in the hand and tenosynovitis in the foot (ICC 0.25-0.44). Intrareader and interreader ICC for change scores varied. Guyatt's responsiveness index (GRI) was high for inflammatory features in the hand and metatarsophalangeal joints (GRI -0.67 to -3.13; bone edema not calculable). Minimal change and low prevalence resulted in low ICC and GRI for bone damage. PsAMRIS showed overall good intrareader agreement in the hand and foot, and inflammatory feature scores were responsive to change, suggesting that PsAMRIS may be a valid tool for MRI assessment of hands and feet in PsA clinical trials.
Automated Ecological Assessment of Physical Activity: Advancing Direct Observation.
Carlson, Jordan A; Liu, Bo; Sallis, James F; Kerr, Jacqueline; Hipp, J Aaron; Staggs, Vincent S; Papa, Amy; Dean, Kelsey; Vasconcelos, Nuno M
2017-12-01
Technological advances provide opportunities for automating direct observations of physical activity, which allow for continuous monitoring and feedback. This pilot study evaluated the initial validity of computer vision algorithms for ecological assessment of physical activity. The sample comprised 6630 seconds per camera (three cameras in total) of video capturing up to nine participants engaged in sitting, standing, walking, and jogging in an open outdoor space while wearing accelerometers. Computer vision algorithms were developed to assess the number and proportion of people in sedentary, light, moderate, and vigorous activity, and group-based metabolic equivalents of tasks (MET)-minutes. Means and standard deviations (SD) of bias/difference values, and intraclass correlation coefficients (ICC) assessed the criterion validity compared to accelerometry separately for each camera. The number and proportion of participants sedentary and in moderate-to-vigorous physical activity (MVPA) had small biases (within 20% of the criterion mean) and the ICCs were excellent (0.82-0.98). Total MET-minutes were slightly underestimated by 9.3-17.1% and the ICCs were good (0.68-0.79). The standard deviations of the bias estimates were moderate-to-large relative to the means. The computer vision algorithms appeared to have acceptable sample-level validity (i.e., across a sample of time intervals) and are promising for automated ecological assessment of activity in open outdoor settings, but further development and testing is needed before such tools can be used in a diverse range of settings.
Automated Ecological Assessment of Physical Activity: Advancing Direct Observation
Carlson, Jordan A.; Liu, Bo; Sallis, James F.; Kerr, Jacqueline; Papa, Amy; Dean, Kelsey; Vasconcelos, Nuno M.
2017-01-01
Technological advances provide opportunities for automating direct observations of physical activity, which allow for continuous monitoring and feedback. This pilot study evaluated the initial validity of computer vision algorithms for ecological assessment of physical activity. The sample comprised 6630 seconds per camera (three cameras in total) of video capturing up to nine participants engaged in sitting, standing, walking, and jogging in an open outdoor space while wearing accelerometers. Computer vision algorithms were developed to assess the number and proportion of people in sedentary, light, moderate, and vigorous activity, and group-based metabolic equivalents of tasks (MET)-minutes. Means and standard deviations (SD) of bias/difference values, and intraclass correlation coefficients (ICC) assessed the criterion validity compared to accelerometry separately for each camera. The number and proportion of participants sedentary and in moderate-to-vigorous physical activity (MVPA) had small biases (within 20% of the criterion mean) and the ICCs were excellent (0.82–0.98). Total MET-minutes were slightly underestimated by 9.3–17.1% and the ICCs were good (0.68–0.79). The standard deviations of the bias estimates were moderate-to-large relative to the means. The computer vision algorithms appeared to have acceptable sample-level validity (i.e., across a sample of time intervals) and are promising for automated ecological assessment of activity in open outdoor settings, but further development and testing is needed before such tools can be used in a diverse range of settings. PMID:29194358
Bösmüller, Hans; Pfefferle, Vanessa; Bittar, Zeid; Scheble, Veit; Horger, Marius; Sipos, Bence; Fend, Falko
2018-06-19
Microvessel density is an indicator of tumor-driven neoangiogenesis. Hepatocellular carcinoma (HCC) and intrahepatic cholangiocarcinoma (ICC) have distinct vascular patterns, which are also reflected in their imaging characteristics. Since a significant proportion of HCC are treated without biopsy confirmation, it is essential to discriminate HCC and ICC radiologically. The aim of our study was therefore to compare microvessel density and expression of VEGFR-2 in HCC and ICC, since these data may ultimately help us to better understand their imaging characteristics. Whereas CD31 documents vessel density, VEGFR-2 expression is an indicator of tumor-related neoangiogenesis. CD31 and VEGFR-2 expressing microvessels were quantified on tissue microarrays of 95 resection specimens of HCC and 47 cases of ICC. Microvessel density was evaluated by counting immuno-reactive vascular structures both within the tumor and adjacent liver control tissue, respectively. Further 16 cases of ICC were immunostained for CD31 and VEGFR-2 on full sections. The frequency of VEGFR-2 (46.2/HPF; range 0-150) and CD31 (61.2/HPF; range 2.6-140) expressing vascular structures was significantly increased in HCC compared to adjacent liver parenchyma (VEGFR-2 33.3/HPF, range 0-87, CD31 21.4/HPF, range 0-78, both p < 0,001). ICC revealed significantly less VEGFR2-positive microvessels (15.4/HPF; range 2-77) compared to matched control tissue (42.3/HPF; range 4.6-109), whereas microvessel density with CD31 was comparable between ICC and adjacent liver (32.1/HPF; range 5.3-78 versus 28.0/HPF; range 5.3-57; p = 0.89). In ICC, the tumor-to-normal microvessel density ratio was 0.38 for VEGFR-2 and 1.24 for CD31. These ratios were nearly identical (VEGFR: 0.38; CD31: 0,97) for the 16 cases of ICC studied on whole sections, confirming the validity of the TMA approach. In contrast, ratios of VEGFR-2 and CD31 in HCC vs. adjacent liver were significantly higher (VEGFR: 2.23; CD31: 6.57). Expression of VEGFR-2 by tumor cells was not observed in any of the cases. HCC and ICC differ significantly in their microvessel density, confirming the hypovascular nature of ICC as compared to the hypervascularity of HCC. Of note, inverse tumor-to-normal ratios of microvascular VEGFR-2 expression between the two neoplasms indicate distinct features of neoangiogenesis. Whether these differences can be exploited for improvements in imaging of hepatic tumors and may play a role for anti-angiogenic treatment strategies requires further studies. Copyright © 2018 Elsevier GmbH. All rights reserved.
NASA Astrophysics Data System (ADS)
Sousa-Herves, Ana; Würfel, Patrick; Wegner, Nicole; Khandare, Jayant; Licha, Kai; Haag, Rainer; Welker, Pia; Calderón, Marcelo
2015-02-01
In this study, dendritic polyglycerol sulfate (dPGS) is evaluated as a delivery platform for the anticancer, tubulin-binding drug paclitaxel (PTX). The conjugation of PTX to dPGS is conducted via a labile ester linkage. A non-sulfated dendritic polyglycerol (dPG) is used as a control, and the labeling with an indocarbocyanine dye (ICC) renders multifunctional conjugates that can be monitored by fluorescence microscopy. The conjugates are characterized by 1H NMR, UV-vis measurements, and RP-HPLC. In vitro cytotoxicity of PTX and dendritic conjugates is evaluated using A549 and A431 cell lines, showing a reduced cytotoxic efficacy of the conjugates compared to PTX. The study of uptake kinetics reveals a linear, non saturable uptake in tumor cells for dPGS-PTX-ICC, while dPG-PTX-ICC is hardly taken up. Despite the marginal uptake of dPG-PTX-ICC, it prompts tubulin polymerization to a comparable extent as PTX. These observations suggest a fast ester hydrolysis and premature drug release, as confirmed by HPLC measurements in the presence of plasma enzymes.In this study, dendritic polyglycerol sulfate (dPGS) is evaluated as a delivery platform for the anticancer, tubulin-binding drug paclitaxel (PTX). The conjugation of PTX to dPGS is conducted via a labile ester linkage. A non-sulfated dendritic polyglycerol (dPG) is used as a control, and the labeling with an indocarbocyanine dye (ICC) renders multifunctional conjugates that can be monitored by fluorescence microscopy. The conjugates are characterized by 1H NMR, UV-vis measurements, and RP-HPLC. In vitro cytotoxicity of PTX and dendritic conjugates is evaluated using A549 and A431 cell lines, showing a reduced cytotoxic efficacy of the conjugates compared to PTX. The study of uptake kinetics reveals a linear, non saturable uptake in tumor cells for dPGS-PTX-ICC, while dPG-PTX-ICC is hardly taken up. Despite the marginal uptake of dPG-PTX-ICC, it prompts tubulin polymerization to a comparable extent as PTX. These observations suggest a fast ester hydrolysis and premature drug release, as confirmed by HPLC measurements in the presence of plasma enzymes. Electronic supplementary information (ESI) available: 1H NMR spectra of the conjugates, HPLC chromatograms, internalization images of dPGS-PTX-ICC (5), elimination kinetics of dPGS-PTX-ICC (5) and dPGS-ICC (7), comparison of IC50 values of PTX and dPGS-PTX (3) in A431 and A549 cell lines and cell viability of dPGS amine (1). See DOI: 10.1039/c4nr04428b
Liu, Zhao-Yun; Sun, Ju-Jie; He, Ke-Wen; Zhuo, Pei-Ying; Yu, Zhi-Yong
2016-07-15
The liver is a common site of metastases, followed by the bone and lung in breast cancer. The symptoms of hepatic metastases are similar to intrahepatic cholangiocarcinoma (ICC). ICC is rare, with an overall incidence rate of 0.95 cases per 100,000 adults. The incidence of ICC for patients with breast cancer is very uncommon. Breast cancer patient with ICC is easily misdiagnosed as hepatic metastases. We report a breast cancer patient postoperatively who was hospitalized because of having continuous irregular fever for 1 month. Antibiotics were given for 1 week without any significant effect. Her admission bloods revealed elevated levels of carcino-embryonic antigen. Magnetic resonance imaging diagnosis showed multiple liver metastases. We believed that the woman had hepatic metastases until biopsy guided by computed tomography. The liver biopsy pathology analysis considered the possibility of primary intrahepatic cholangiocarcinoma. Breast cancer patient with space-occupying lesions in the liver is easily considered to be progressed hepatic metastases. Image-guided biopsy is the best diagnostic method for breast cancer with liver mass to avoid misdiagnosis and classify the molecular subtypes to make appropriate treatment.
NASA Astrophysics Data System (ADS)
Papers are presented on ISDN, mobile radio systems and techniques for digital connectivity, centralized and distributed algorithms in computer networks, communications networks, quality assurance and impact on cost, adaptive filters in communications, the spread spectrum, signal processing, video communication techniques, and digital satellite services. Topics discussed include performance evaluation issues for integrated protocols, packet network operations, the computer network theory and multiple-access, microwave single sideband systems, switching architectures, fiber optic systems, wireless local communications, modulation, coding, and synchronization, remote switching, software quality, transmission, and expert systems in network operations. Consideration is given to wide area networks, image and speech processing, office communications application protocols, multimedia systems, customer-controlled network operations, digital radio systems, channel modeling and signal processing in digital communications, earth station/on-board modems, computer communications system performance evaluation, source encoding, compression, and quantization, and adaptive communications systems.
Temporal Stability of the Ford Insomnia Response to Stress Test (FIRST).
Jarrin, Denise C; Chen, Ivy Y; Ivers, Hans; Drake, Christopher L; Morin, Charles M
2016-10-15
The Ford Insomnia Response to Stress Test (FIRST) is a self-report tool that measures sleep reactivity (i.e., vulnerability to experience situational insomnia under stressful conditions). Sleep reactivity has been termed a "trait-like" vulnerability; however, evidence of its long-term stability is lacking. The main objective of the current psychometric study was to investigate the temporal stability of the FIRST over two 6-mo intervals in a population-based sample of adults with and without insomnia. The temporal stability of the FIRST was also compared with the temporal stability of other scales associated with insomnia (trait-anxiety, arousability). Participants included 1,122 adults (mean age = 49.9 y, standard deviation = 14.8; 38.8% male) presenting with an insomnia syndrome (n = 159), insomnia symptoms (n = 152), or good sleep (n = 811). Participants completed the FIRST, the State-Trait Anxiety Inventory (trait-anxiety), and the Arousal Predisposition Scale (arousability) on three different occasions: baseline and at 6- and 12-mo follow-up. Intraclass correlation coefficients (ICCs) were computed for all scales (baseline to 6 mo and 6 to 12 mo). The FIRST yielded strong temporal stability from baseline to 6 mo among those with insomnia syndrome (ICC = 0.81), symptoms (ICC = 0.78), and good sleep (ICC = 0.81). Similar results were observed for 6 to 12 mo among those with insomnia syndrome (ICC = 0.74), insomnia symptoms (ICC = 0.82), and good sleep (ICC = 0.84). The stability of the FIRST was not comparable with the stability of trait-anxiety, but was somewhat comparable with the stability of arousability. Overall, the FIRST is a temporally reliable stable scale over 6-mo intervals. Future research is needed to corroborate the stability and trait-like measures of sleep reactivity with physiological, behavioural and personality measures. © 2016 American Academy of Sleep Medicine
Breast MRI radiomics: comparison of computer- and human-extracted imaging phenotypes.
Sutton, Elizabeth J; Huang, Erich P; Drukker, Karen; Burnside, Elizabeth S; Li, Hui; Net, Jose M; Rao, Arvind; Whitman, Gary J; Zuley, Margarita; Ganott, Marie; Bonaccio, Ermelinda; Giger, Maryellen L; Morris, Elizabeth A
2017-01-01
In this study, we sought to investigate if computer-extracted magnetic resonance imaging (MRI) phenotypes of breast cancer could replicate human-extracted size and Breast Imaging-Reporting and Data System (BI-RADS) imaging phenotypes using MRI data from The Cancer Genome Atlas (TCGA) project of the National Cancer Institute. Our retrospective interpretation study involved analysis of Health Insurance Portability and Accountability Act-compliant breast MRI data from The Cancer Imaging Archive, an open-source database from the TCGA project. This study was exempt from institutional review board approval at Memorial Sloan Kettering Cancer Center and the need for informed consent was waived. Ninety-one pre-operative breast MRIs with verified invasive breast cancers were analysed. Three fellowship-trained breast radiologists evaluated the index cancer in each case according to size and the BI-RADS lexicon for shape, margin, and enhancement (human-extracted image phenotypes [HEIP]). Human inter-observer agreement was analysed by the intra-class correlation coefficient (ICC) for size and Krippendorff's α for other measurements. Quantitative MRI radiomics of computerised three-dimensional segmentations of each cancer generated computer-extracted image phenotypes (CEIP). Spearman's rank correlation coefficients were used to compare HEIP and CEIP. Inter-observer agreement for HEIP varied, with the highest agreement seen for size (ICC 0.679) and shape (ICC 0.527). The computer-extracted maximum linear size replicated the human measurement with p < 10 -12 . CEIP of shape, specifically sphericity and irregularity, replicated HEIP with both p values < 0.001. CEIP did not demonstrate agreement with HEIP of tumour margin or internal enhancement. Quantitative radiomics of breast cancer may replicate human-extracted tumour size and BI-RADS imaging phenotypes, thus enabling precision medicine.
Bolesta, Michael J; Winslow, Lauren; Gill, Kevin
2010-06-01
A comparison of measurements of degenerative spondylolisthesis made on film and on computer workstations. To determine whether the 2 methodologies are comparable in some of the parameters used to assess lumbar degenerative spondylolisthesis. Digital radiology has been replacing analog radiographs. In scoliosis, several studies have shown that measurements made on digital and analog films are similar and that they are also similar to those made on computer workstations. Such work has not been done in spondylolisthesis. Twenty-four cases of lumbar degenerative spondylolisthesis were identified from our clinic practice. Three observers measured anterior displacement, sagittal rotation, and lumbar lordosis on digital films using the same protractor and pencil. The same parameters were measured on the same studies at clinical workstations. All measurements were repeated 2 weeks later. A statistician determined the intra and interobserver reliability of the 2 measurement methods and the degree of agreement between the 2 methods. The differences between the first and second readings did reach statistical significance in some cases, but none of them were large enough to be clinically meaningful. The interclass correlation coefficients (ICCs) were >or=0.80 except for one (0.67). The difference among the 3 observers was similarly statistically significant in a few instances but not enough to influence clinical decisions and with good ICCs (0.67 and better). Similarly, the differences in the 2 methods were small, and ICCs ranged from 0.69 to 0.98. This study supports the use of computer workstation measurements in lumbar degenerative spondylolisthesis. The parameters used in this study were comparable, whether measured on film or at clinical workstations.
Priority Setting for Improvement of Cervical Cancer Prevention in Iran.
Majidi, Azam; Ghiasvand, Reza; Hadji, Maryam; Nahvijou, Azin; Mousavi, Azam-Sadat; Pakgohar, Minoo; Khodakarami, Nahid; Abedini, Mehrandokht; Amouzegar Hashemi, Farnaz; Rahnamaye Farzami, Marjan; Shahsiah, Reza; Sajedinejhad, Sima; Mohagheghi, Mohammad Ali; Nadali, Fatemeh; Rashidian, Arash; Weiderpass, Elisabete; Mogensen, Ole; Zendehdel, Kazem
2015-11-22
Cervical cancer is the fourth most common cancer among women worldwide. Organized cervical screening and vaccination against human papilloma virus (HPV) have been successful interventions for prevention of invasive cervical cancer (ICC). Because of cultural and religious considerations, ICC has low incidence in Iran and many other Muslim countries. There is no organized cervical screening in these countries. Therefore, ICC is usually diagnosed in advanced stages with poor prognosis in these countries. We performed a priority setting exercise and suggested priorities for prevention of ICC in this setting. We invited experts and researchers to a workshop and asked them to list important suggestions for ICC prevention in Iran. After merging similar items and removing the duplicates, we asked the experts to rank the list of suggested items. We used a strategy grid and Go-zone analysis to determine final list of priorities for ICC prevention in Iran. From 26 final items suggested as priorities for prevention of ICC, the most important priorities were developing national guidelines for cervical screening and quality control protocol for patient follow-up and management of precancerous lesions. In addition, we emphasized considering insurance coverage for cervical screening, public awareness, and research priorities, and establishment of a cervical screening registry. A comprehensive approach and implementation of organized cervical screening program is necessary for prevention of ICC in Iran and other low incidence Muslim countries. Because of high cost for vaccination and low incidence of cervical cancer, we do not recommend HPV vaccination for the time being in Iran. © 2016 by Kerman University of Medical Sciences.
Priority Setting for Improvement of Cervical Cancer Prevention in Iran
Majidi, Azam; Ghiasvand, Reza; Hadji, Maryam; Nahvijou, Azin; Mousavi, Azam-Sadat; Pakgohar, Minoo; Khodakarami, Nahid; Abedini, Mehrandokht; Amouzegar Hashemi, Farnaz; Rahnamaye Farzami, Marjan; Shahsiah, Reza; Sajedinejhad, Sima; Mohagheghi, Mohammad Ali; Nadali, Fatemeh; Rashidian, Arash; Weiderpass, Elisabete; Mogensen, Ole; Zendehdel, Kazem
2016-01-01
Background: Cervical cancer is the fourth most common cancer among women worldwide. Organized cervical screening and vaccination against human papilloma virus (HPV) have been successful interventions for prevention of invasive cervical cancer (ICC). Because of cultural and religious considerations, ICC has low incidence in Iran and many other Muslim countries. There is no organized cervical screening in these countries. Therefore, ICC is usually diagnosed in advanced stages with poor prognosis in these countries. We performed a priority setting exercise and suggested priorities for prevention of ICC in this setting. Methods: We invited experts and researchers to a workshop and asked them to list important suggestions for ICC prevention in Iran. After merging similar items and removing the duplicates, we asked the experts to rank the list of suggested items. We used a strategy grid and Go-zone analysis to determine final list of priorities for ICC prevention in Iran. Results: From 26 final items suggested as priorities for prevention of ICC, the most important priorities were developing national guidelines for cervical screening and quality control protocol for patient follow-up and management of precancerous lesions. In addition, we emphasized considering insurance coverage for cervical screening, public awareness, and research priorities, and establishment of a cervical screening registry. Conclusion: A comprehensive approach and implementation of organized cervical screening program is necessary for prevention of ICC in Iran and other low incidence Muslim countries. Because of high cost for vaccination and low incidence of cervical cancer, we do not recommend HPV vaccination for the time being in Iran. PMID:27239863
Ulcerative colitis: ultrastructure of interstitial cells in myenteric plexus.
Rumessen, J J; Vanderwinden, J-M; Horn, T
2010-10-01
Interstitial cells of Cajal (ICC) are key regulatory cells in the gut. In the colon of patients with severe ulcerative colitis (UC), myenteric ICC had myoid ultrastructural features and were in close contact with nerve terminals. In all patients as opposed to controls, some ICC profiles showed degenerative changes, such as lipid droplets and irregular vacuoles. Nerve terminals often appeared swollen and empty. Glial cells, muscle cells, and fibroblast-like cells (FLC) showed no alterations. FLC enclosed macrophages (MLC), which were in close contact with naked axon terminals. The organization and cytological changes may be of pathophysiological significance in patients with UC.
Nielsen, Tove Lise; Andersen, Niels Trolle; Petersen, Kirsten Schultz; Polatajko, Helene; Nielsen, Claus Vinther
2018-01-12
There is growing interest in enabling older adults' occupational performance. We tested whether 11 weeks of intensive client-centred occupational therapy (ICC-OT) was superior to usual practice in improving the occupational performance of home-dwelling older adults. An assessor-masked randomized controlled trial among adults 60 + with chronic health issues, who received or applied for homecare services. Recruitment took place September 2012 to April 2014. All participants received practical and personal assistance and meal delivery as needed. In addition, they were randomized to receive either a maximum 22 sessions of occupation-based ICC-OT (N = 59) or to receive usual practice with a maximum three sessions of occupational therapy (N = 60). The primary outcome was self-rated occupational performance assessed with the Canadian Occupational Performance Measure (COPM). No important adverse events occurred. ICC-OT was accepted by 46 participants (88%), usual practice by 60 (100%). After 3 months, the ICC-OT-group had improved 1.86 points on COPM performance; the Usual-Practice group had improved 0.61 points. The between-group difference was statistically significant (95% confidence interval 0.50 to 2.02), t-test: p = 0.001. ICC-OT improved older adults' occupational performance more effectively than usual practice. This result may benefit older adults and support programmatic changes.
Intrahepatic Cholangiocarcinoma: expert consensus statement
Weber, Sharon M; Ribero, Dario; O=Reilly, Eileen M; Kokudo, Norihiro; Miyazaki, Masaru; Pawlik, Timothy M
2015-01-01
An American Hepato-Pancreato-Biliary Association (AHPBA)-sponsored consensus meeting of expert panellists met on 15 January 2014 to review current evidence on the management of intrahepatic cholangiocarcinoma (ICC) in order to establish practice guidelines and to agree on consensus statements. The treatment of ICC requires a coordinated, multidisciplinary approach to optimize survival. Biopsy is not necessary if the surgeon suspects ICC and is planning curative resection, although biopsy should be obtained before systemic or locoregional therapies are initiated. Assessment of resectability is best accomplished using cross-sectional imaging [computed tomography (CT) or magnetic resonance imaging (MRI)], but the role of positron emission tomography (PET) is unclear. Resectability in ICC is defined by the ability to completely remove the disease while leaving an adequate liver remnant. Extrahepatic disease, multiple bilobar or multicentric tumours, and lymph node metastases beyond the primary echelon are contraindications to resection. Regional lymphadenectomy should be considered a standard part of surgical therapy. In patients with high-risk features, the routine use of diagnostic laparoscopy is recommended. The preoperative diagnosis of combined hepatocellular carcinoma and cholangiocarcinoma (cHCC–CC) by imaging studies is extremely difficult. Surgical resection remains the mainstay of treatment, but survival is worse than in HCC alone. There are no adequately powered, randomized Phase III trials that can provide definitive recommendations for adjuvant therapy for ICC. Patients with high-risk features (lymphovascular invasion, multicentricity or satellitosis, large tumours) should be encouraged to enrol in clinical trials and to consider adjuvant therapy. Cisplatin plus gemcitabine represents the standard-of-care, front-line systemic therapy for metastatic ICC. Genomic analyses of biliary cancers support the development of targeted therapeutic interventions. PMID:26172134
Eide, Per Kristian
2016-12-01
OBJECTIVE The objective of this study was to examine how pulsatile and static intracranial pressure (ICP) scores correlate with indices of intracranial pressure-volume reserve capacity, i.e., intracranial elastance (ICE) and intracranial compliance (ICC), as determined during ventricular infusion testing. METHODS All patients undergoing ventricular infusion testing and overnight ICP monitoring during the 6-year period from 2007 to 2012 were included in the study. Clinical data were retrieved from a quality registry, and the ventricular infusion pressure data and ICP scores were retrieved from a pressure database. The ICE and ICC (= 1/ICE) were computed during the infusion phase of the infusion test. RESULTS During the period from 2007 to 2012, 82 patients with possible treatment-dependent hydrocephalus underwent ventricular infusion testing within the department of neurosurgery. The infusion tests revealed a highly significant positive correlation between ICE and the pulsatile ICP scores mean wave amplitude (MWA) and rise-time coefficient (RTC), and the static ICP score mean ICP. The ICE was negatively associated with linear measures of ventricular size. The overnight ICP recordings revealed significantly increased MWA (> 4 mm Hg) and RTC (> 20 mm Hg/sec) values in patients with impaired ICC (< 0.5 ml/mm Hg). CONCLUSIONS In this study cohort, there was a significant positive correlation between pulsatile ICP and ICE measured during ventricular infusion testing. In patients with impaired ICC during infusion testing (ICC < 0.5 ml/mm Hg), overnight ICP recordings showed increased pulsatile ICP (MWA > 4 mm Hg, RTC > 20 mm Hg/sec), but not increased mean ICP (< 10-15 mm Hg). The present data support the assumption that pulsatile ICP (MWA and RTC) may serve as substitute markers of pressure-volume reserve capacity, i.e., ICE and ICC.
Wistermayer, Paul R; McIlwain, Wesley R; Ieronimakis, Nicholas; Rogers, Derek J
2018-04-01
Validate an accurate and reproducible method of measuring the cross-sectional area (CSA) of the upper airway. This is a prospective animal study done at a tertiary care medical treatment facility. Control images were obtained using endotracheal tubes of varying sizes. In vivo images were obtained from various timepoints of a concurrent study on subglottic stenosis. Using a 0° rod telescope, an instrument was placed at the level of interest, and a photo was obtained. Three independent and blinded raters then measured the CSA of the narrowest portion of the airway using open source image analysis software. Each blinded rater measured the CSA of 79 photos. The t testing to assess for accuracy showed no difference between measured and known CSAs of the control images ( P = .86), with an average error of 1.5% (SD = 5.5%). All intraclass correlation (ICC) values for intrarater agreement showed excellent agreement (ICC > .75). Interrater reliability among all raters in control (ICC = .975; 95% CI, .817-.995) and in vivo (ICC = .846;, 95% CI, .780-.896) images showed excellent agreement. We validate a simple, accurate, and reproducible method of measuring the CSA of the airway that can be used in a clinical or research setting.
Andersen, Lars Bo; Skrede, Turid; Ekelund, Ulf; Anderssen, Sigmund Alfred; Resaland, Geir Kåre
2017-01-01
Introduction Knowledge of reproducibility of accelerometer-determined physical activity (PA) and sedentary time (SED) estimates are a prerequisite to conduct high-quality epidemiological studies. Yet, estimates of reproducibility might differ depending on the approach used to analyze the data. The aim of the present study was to determine the reproducibility of objectively measured PA and SED in children by directly comparing a day-by-day and a week-by-week approach to data collected over two weeks during two different seasons 3–4 months apart. Methods 676 11-year-old children from the Active Smarter Kids study conducted in Sogn og Fjordane county, Norway, performed 7 days of accelerometer monitoring (ActiGraph GT3X+) during January-February and April-May 2015. Reproducibility was calculated using a day-by-day and a week-by-week approach applying mixed effect modelling and the Spearman Brown prophecy formula, and reported using intra-class correlation (ICC), Bland Altman plots and 95% limits of agreement (LoA). Results Applying a week-by-week approach, no variables provided ICC estimates ≥ 0.70 for one week of measurement in any model (ICC = 0.29–0.66 not controlling for season; ICC = 0.49–0.67 when controlling for season). LoA for these models approximated a factor of 1.3–1.7 of the sample PA level standard deviations. Compared to the week-by-week approach, the day-by-day approach resulted in too optimistic reliability estimates (ICC = 0.62–0.77 not controlling for season; ICC = 0.64–0.77 when controlling for season). Conclusions Reliability is lower when analyzed over different seasons and when using a week-by-week approach, than when applying a day-by-day approach and the Spearman Brown prophecy formula to estimate reliability over a short monitoring period. We suggest a day-by-day approach and the Spearman Brown prophecy formula to determine reliability be used with caution. Trial Registration The study is registered in Clinicaltrials.gov 7th April 2014 with identification number NCT02132494. PMID:29216318
Camargo, Diana Marina; Santisteban, Stefany; Paredes, Erika; Flórez, Mary Ann; Bueno, Diego
2015-01-01
International recommendations for physical activity and time spent in sedentary behaviors for children in their early years require the availability of measuring instruments with psychometric properties that allow for the assessment of population dynamics and interventions to improve health. To evaluate the reliability of a questionnaire to measure physical activity and sedentary behaviors in children from preschool to fourth grade. One hundred and eight parents answered the questionnaire. The instrument included socio-demographic variables, as well as those associated with physical activity, including time walking to school, organized sports and playtime activities. Sedentary behaviors included motorized transport to school, reading and "screen time", sleeping and extracurricular courses. Internal consistency, reproducibility and agreement were evaluated using Cronbach's alpha coefficient, the Intraclass Correlation Coefficient (ICC) and the Bland and Altman limits of agreement method, respectively. Internal consistency for physical activity ranged from 0.59 to 0.64, and for sedentary behaviors between 0.22 and 0.34. The highest reproducibility was found for walking to school and time spent on this (kappa=0.79, ICC 0.69), and organized sports, and time on this activity (kappa=0.72, ICC 0.76). Among sedentary behaviors, motorized transport to school and computer use showed kappas of 0.82 and 0.71, respectively; additionally, the time spent on these behaviors showed an ICC of 0.8 and 0.59, respectively. We found limits of agreement between moderate and good for reading time, napping, extracurricular courses, computer and console use. The questionnaire provided reliable information on the physical activity and sedentary behaviors in children under 10 years of age and could be used in other Latin American countries.
Reliability of the Achilles tendon tap reflex evoked during stance using a pendulum hammer.
Mildren, Robyn L; Zaback, Martin; Adkin, Allan L; Frank, James S; Bent, Leah R
2016-01-01
The tendon tap reflex (T-reflex) is often evoked in relaxed muscles to assess spinal reflex circuitry. Factors contributing to reflex excitability are modulated to accommodate specific postural demands. Thus, there is a need to be able to assess this reflex in a state where spinal reflex circuitry is engaged in maintaining posture. The aim of this study was to determine whether a pendulum hammer could provide controlled stimuli to the Achilles tendon and evoke reliable muscle responses during normal stance. A second aim was to establish appropriate stimulus parameters for experimental use. Fifteen healthy young adults stood on a forceplate while taps were applied to the Achilles tendon under conditions in which postural sway was constrained (by providing centre of pressure feedback) or unconstrained (no feedback) from an invariant release angle (50°). Twelve participants repeated this testing approximately six months later. Within one experimental session, tap force and T-reflex amplitude were found to be reliable regardless of whether postural sway was constrained (tap force ICC=0.982; T-reflex ICC=0.979) or unconstrained (tap force ICC=0.968; T-reflex ICC=0.964). T-reflex amplitude was also reliable between experimental sessions (constrained ICC=0.894; unconstrained ICC=0.890). When a T-reflex recruitment curve was constructed, optimal mid-range responses were observed using a 50° release angle. These results demonstrate that reliable Achilles T-reflexes can be evoked in standing participants without the need to constrain posture. The pendulum hammer provides a simple method to allow researchers and clinicians to gather information about reflex circuitry in a state where it is involved in postural control. Copyright © 2015 Elsevier B.V. All rights reserved.
Timing of umbilical cord clamping among infants born at 22 through 27 weeks' gestation.
Backes, C H; Huang, H; Iams, J D; Bauer, J A; Giannone, P J
2016-01-01
To investigate the safety, feasibility and efficacy of delayed cord clamping (DCC) compared with immediate cord clamping (ICC) at delivery among infants born at 22 to 27 weeks' gestation. This was a pilot, randomized, controlled trial in which women in labor with singleton pregnancies at 22 to 27 weeks' gestation were randomly assigned to ICC (cord clamped at 5 to 10 s) or DCC (30 to 45 s). Forty mother-infant pairs were randomized. Infants in the ICC and DCC groups had mean gestational ages (GA) of 24.6 and 24.4 weeks, respectively. No differences were observed between the groups across all available safety measures, although infants in the DCC group had higher admission temperatures than infants in the ICC group (97.4 vs. 96.2 °F, P=0.04). During the first 24 h of life, blood pressures were lower in the ICC group than in the DCC group (P<0.05), despite a threefold greater incidence of treatment for hypotension (45% vs. 12%, P<0.01). Infants in the ICC group had increased numbers of red blood transfusions (in first 28 days of life) than infants in DCC group (4.1±3.9 vs. 2.8±2.2, P=0.04). Among infants born at an average GA of 24 weeks', DCC appears safe, logistically feasible, and offers hematological and circulatory advantages compared with ICC. A more comprehensive appraisal of this practice is needed.
Ladwig, R; Vigo, A; Fedeli, L M G; Chambless, L E; Bensenor, I; Schmidt, M I; Vidigal, P G; Castilhos, C D; Duncan, B B
2016-08-01
Multi-center epidemiological studies must ascertain that their measurements are accurate and reliable. For laboratory measurements, reliability can be assessed through investigation of reproducibility of measurements in the same individual. In this paper, we present results from the quality control analysis of the baseline laboratory measurements from the ELSA-Brasil study. The study enrolled 15,105 civil servants at 6 research centers in 3 regions of Brazil between 2008-2010, with multiple biochemical analytes being measured at a central laboratory. Quality control was ascertained through standard laboratory evaluation of intra- and inter-assay variability and test-retest analysis in a subset of randomly chosen participants. An additional sample of urine or blood was collected from these participants, and these samples were handled in the same manner as the original ones, locally and at the central laboratory. Reliability was assessed with the intraclass correlation coefficient (ICC), estimated through a random effects model. Coefficients of variation (CV) and Bland-Altman plots were additionally used to assess measurement variability. Laboratory intra and inter-assay CVs varied from 0.86% to 7.77%. From test-retest analyses, the ICCs were high for the majority of the analytes. Notably lower ICCs were observed for serum sodium (ICC=0.50; 95%CI=0.31-0.65) and serum potassium (ICC=0.73; 95%CI=0.60-0.83), due to the small biological range of these analytes. The CVs ranged from 1 to 14%. The Bland-Altman plots confirmed these results. The quality control analyses showed that the collection, processing and measurement protocols utilized in the ELSA-Brasil produced reliable biochemical measurements.
Telecommunications Is Here and Now.
ERIC Educational Resources Information Center
Clark, Chris
1988-01-01
Presents an overview of telecommunications and its use in the field of education. Topics discussed include conferencing, electronic messaging, distance learning, networking, database searching, and projects relating to educational telecommunications sponsored by the International Council for Computers in Education (ICCE). (LRW)
Diversity of bilateral synaptic assemblies for binaural computation in midbrain single neurons.
He, Na; Kong, Lingzhi; Lin, Tao; Wang, Shaohui; Liu, Xiuping; Qi, Jiyao; Yan, Jun
2017-11-01
Binaural hearing confers many beneficial functions but our understanding of its underlying neural substrates is limited. This study examines the bilateral synaptic assemblies and binaural computation (or integration) in the central nucleus of the inferior colliculus (ICc) of the auditory midbrain, a key convergent center. Using in-vivo whole-cell patch-clamp, the excitatory and inhibitory postsynaptic potentials (EPSPs/IPSPs) of single ICc neurons to contralateral, ipsilateral and bilateral stimulation were recorded. According to the contralateral and ipsilateral EPSP/IPSP, 7 types of bilateral synaptic assemblies were identified. These include EPSP-EPSP (EE), E-IPSP (EI), E-no response (EO), II, IE, IO and complex-mode (CM) neurons. The CM neurons showed frequency- and/or amplitude-dependent EPSPs/IPSPs to contralateral or ipsilateral stimulation. Bilateral stimulation induced EPSPs/IPSPs that could be larger than (facilitation), similar to (ineffectiveness) or smaller than (suppression) those induced by contralateral stimulation. Our findings have allowed our group to characterize novel neural circuitry for binaural computation in the midbrain. Copyright © 2017 Elsevier B.V. All rights reserved.
Han, Jeong Yeob; Wise, Meg; Kim, Eunkyung; Pingree, Ray; Hawkins, Robert P.; Pingree, Suzanne; McTavish, Fiona; Gustafson, David H.
2011-01-01
In order to provide insights about cancer patients’ online information seeking behaviors, the present study analyzes individuals’ transaction log data and reports on how demographics, disease-related factors, and psychosocial needs predict patterns of service use within a particular Interactive Cancer Communication System (ICCS). Study sample included 294 recently diagnosed breast cancer patients. Data included pretest survey scores of demographic, disease-related, and psychosocial factors and automatically collected ICCS use data over the 4-month intervention. Statistical analyses correlated pre-test survey scores with subsequent, specific types of ICCS service usage. Patterns of online cancer information seeking differed according to the patients’ characteristics, suggesting that lower income, less educated women and those lacking in information-seeking competence use the computer and online services to the same or a greater degree if those services are made available to them. Results of this study can inform more effective resource development for future eHealth applications. PMID:21760702
Fan, Ying; Wu, Shuo-Dong; Fu, Bei-Bei; Weng, Chao; Wang, Xin-Peng
2014-01-01
To study the changes of interstitial cells of Cajal (ICCs) and expression of c-kt and scf mRNA in terminal ileum tissue during cholesterol gallstone formation in guinea pigs fed on high cholesterol diet, forty guinea pigs were divided into the gallstone group and the control group. The animals in the gallstone group were fed on a high cholesterol diet (HCD), while those in the control group fed on a standard diet (StD). The guinea pigs were sacrificed at the 8th week. The expression of c-kit and scf in terminal ileum were determined by RT-PCR and the morphological characteristics and number of ICCs were observed and calculated by using immunohistochemistry. RT-PCR showed that, compared with the control group, the c-kit and scf mRNA expression levels in the gallstone group were significantly declined. In the animal assay, the decreased number of ICCs was present obviously in the gallstone group. We concluded from the study that decreased number of ICCs, decreased expression of c-kit and scf in terminal ileum are present in guinea pigs fed on high cholesterol diet. The c-kit/scf pathway inhibition might be involved in the decline of intestinal transit function during cholesterol gallstone formation. PMID:24995081
2014-01-01
Background Little is known about the reliability of different methods of survey administration in low back pain trials. This analysis was designed to determine the reliability of responses to self-administered paper surveys compared to computer assisted telephone interviews (CATI) for the primary outcomes of pain intensity and back-related function, and secondary outcomes of patient satisfaction, SF-36, and global improvement among participants enrolled in a study of yoga for chronic low back pain. Results Pain intensity, back-related function, and both physical and mental health components of the SF-36 showed excellent reliability at all three time points; ICC scores ranged from 0.82 to 0.98. Pain medication use showed good reliability; kappa statistics ranged from 0.68 to 0.78. Patient satisfaction had moderate to excellent reliability; ICC scores ranged from 0.40 to 0.86. Global improvement showed poor reliability at 6 weeks (ICC = 0.24) and 12 weeks (ICC = 0.10). Conclusion CATI shows excellent reliability for primary outcomes and at least some secondary outcomes when compared to self-administered paper surveys in a low back pain yoga trial. Having two reliable options for data collection may be helpful to increase response rates for core outcomes in back pain trials. Trial registration ClinicalTrials.gov: NCT01761617. Date of trial registration: December 4, 2012. PMID:24716775
Comparison of 2 Radiographic Techniques for Measurement of Tibiofemoral Joint Space Width.
Mehta, Nabil; Duryea, Jeffrey; Badger, Gary J; Akelman, Matthew R; Jones, Morgan H; Spindler, Kurt P; Fleming, Braden C
2017-09-01
No consensus is available regarding the best method for measuring tibiofemoral joint space width (JSW) on radiographs to quantify joint changes after injury. Studies that track articular cartilage thickness after injury frequently use patients' uninjured contralateral knees as controls, although the literature supporting this comparison is limited. (1) To compare JSW measurements using 2 established measurement techniques in healthy control participants and (2) to determine whether the mean JSW of the uninjured contralateral knee in a cohort with anterior cruciate ligament (ACL) reconstruction is different from that obtained from a true control population. Cohort study (diagnosis); Level of evidence, 2. Medial and lateral JSWs were measured on standardized, bilateral, semiflexed metatarsophalangeal positioning, posteroanterior radiographs of 60 healthy individuals (26 females; mean ± SD age, 25 ± 6.2 years; no history of knee injury) via 2 published techniques: a computerized surface-delineation method (surface-fit method) and a manual digitization method (midpoint method). Bland-Altman method was used to examine the agreement between JSW measurements obtained with the 2 methods and to examine the agreement between measurements obtained on left and right knees within a participant for each measurement method. Within- and between-participant variance components and intraclass correlation coefficients (ICCs) were computed for JSW measurements corresponding to each method. Two-sample t tests were used to compare the surface-fit method measurements of mean JSW of the true control group (n = 60) with the previously published mean JSW measurements from the Multicenter Orthopaedics Outcomes Network (MOON) nested cohort of 262 contralateral uninjured knees 2 to 3 years after ACL reconstruction. For JSW in the medial compartment, the surface-fit method had lower within-participant interknee variability (σ 2 within , 0.064; 95% CI, 0.04-0.09) compared with the midpoint method (σ 2 within , 0.28; 95% CI, 0.20-0.43) and a higher ICC (0.93 vs 0.65; P < .001). Lateral JSW values were similar for the surface-fit method (σ 2 within , 0.27; 95% CI, 0.18-0.43) and the midpoint method (σ 2 within , 0.20; 95% CI, 0.14-0.31), with ICCs of 0.75 and 0.77, respectively ( P = .80). With the surface-fit method, mean JSW measurements of the medial and lateral compartments of a control population were not significantly different from the contralateral uninjured knees of patients after ACL reconstruction. For measuring medial JSW, the surface-fit method was less variable across knees within a participant than the midpoint method, as evidenced by larger ICCs and lower interknee variability. For measuring lateral JSW, the 2 methods were similar. The JSW measurements of uninjured contralateral knees of patients with ACL reconstruction at 2 to 3 years postsurgery were not significantly different from those of a cohort of healthy control participants. Future work should be performed to demonstrate the validity of these methods for documenting change over time in the ACL-reconstructed knee.
Martin, Bryn A; Yiallourou, Theresia I; Pahlavian, Soroush Heidari; Thyagaraj, Suraj; Bunck, Alexander C; Loth, Francis; Sheffer, Daniel B; Kröger, Jan Robert; Stergiopulos, Nikolaos
2016-05-01
For the first time, inter-operator dependence of MRI based computational fluid dynamics (CFD) modeling of cerebrospinal fluid (CSF) in the cervical spinal subarachnoid space (SSS) is evaluated. In vivo MRI flow measurements and anatomy MRI images were obtained at the cervico-medullary junction of a healthy subject and a Chiari I malformation patient. 3D anatomies of the SSS were reconstructed by manual segmentation by four independent operators for both cases. CFD results were compared at nine axial locations along the SSS in terms of hydrodynamic and geometric parameters. Intraclass correlation (ICC) assessed the inter-operator agreement for each parameter over the axial locations and coefficient of variance (CV) compared the percentage of variance for each parameter between the operators. Greater operator dependence was found for the patient (0.19 < ICC < 0.99) near the craniovertebral junction compared to the healthy subject (ICC > 0.78). For the healthy subject, hydraulic diameter and Womersley number had the least variance (CV = ~2%). For the patient, peak diastolic velocity and Reynolds number had the smallest variance (CV = ~3%). These results show a high degree of inter-operator reliability for MRI-based CFD simulations of CSF flow in the cervical spine for healthy subjects and a lower degree of reliability for patients with Type I Chiari malformation.
Martin, Bryn A.; Yiallourou, Theresia I.; Pahlavian, Soroush Heidari; Thyagaraj, Suraj; Bunck, Alexander C.; Loth, Francis; Sheffer, Daniel B.; Kröger, Jan Robert; Stergiopulos, Nikolaos
2015-01-01
For the first time, inter-operator dependence of MRI based computational fluid dynamics (CFD) modeling of cerebrospinal fluid (CSF) in the cervical spinal subarachnoid space (SSS) is evaluated. In vivo MRI flow measurements and anatomy MRI images were obtained at the cervico-medullary junction of a healthy subject and a Chiari I malformation patient. 3D anatomies of the SSS were reconstructed by manual segmentation by four independent operators for both cases. CFD results were compared at nine axial locations along the SSS in terms of hydrodynamic and geometric parameters. Intraclass correlation (ICC) assessed the inter-operator agreement for each parameter over the axial locations and coefficient of variance (CV) compared the percentage of variance for each parameter between the operators. Greater operator dependence was found for the patient (0.19
Hippo Cascade Controls Lineage Commitment of Liver Tumors in Mice and Humans.
Zhang, Shanshan; Wang, Jingxiao; Wang, Haichuan; Fan, Lingling; Fan, Biao; Zeng, Billy; Tao, Junyan; Li, Xiaolei; Che, Li; Cigliano, Antonio; Ribback, Silvia; Dombrowski, Frank; Chen, Bin; Cong, Wenming; Wei, Lixin; Calvisi, Diego F; Chen, Xin
2018-04-01
Primary liver cancer consists mainly of hepatocellular carcinoma (HCC) and intrahepatic cholangiocarcinoma (ICC). A subset of human HCCs expresses a ICC-like gene signature and is classified as ICC-like HCC. The Hippo pathway is a critical regulator of normal and malignant liver development. However, the precise function(s) of the Hippo cascade along liver carcinogenesis remain to be fully delineated. The role of the Hippo pathway in a murine mixed HCC/ICC model induced by activated forms of AKT and Ras oncogenes (AKT/Ras) was investigated. The authors demonstrated the inactivation of Hippo in AKT/Ras liver tumors leading to nuclear localization of Yap and TAZ. Coexpression of AKT/Ras with Lats2, which activates Hippo, or the dominant negative form of TEAD2 (dnTEAD2), which blocks Yap/TAZ activity, resulted in delayed hepatocarcinogenesis and elimination of ICC-like lesions in the liver. Mechanistically, Notch2 expression was found to be down-regulated by the Hippo pathway in liver tumors. Overexpression of Lats2 or dnTEAD2 in human HCC cell lines inhibited their growth and led to the decreased expression of ICC-like markers, as well as Notch2 expression. Altogether, this study supports the key role of the Hippo cascade in regulating the differentiation status of liver tumors. Copyright © 2018 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.
SU-F-R-51: Radiomics in CT Perfusion Maps of Head and Neck Cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nesteruk, M; Riesterer, O; Veit-Haibach, P
2016-06-15
Purpose: The aim of this study was to test the predictive value of radiomics features of CT perfusion (CTP) for tumor control, based on a preselection of radiomics features in a robustness study. Methods: 11 patients with head and neck cancer (HNC) and 11 patients with lung cancer were included in the robustness study to preselect stable radiomics parameters. Data from 36 HNC patients treated with definitive radiochemotherapy (median follow-up 30 months) was used to build a predictive model based on these parameters. All patients underwent pre-treatment CTP. 315 texture parameters were computed for three perfusion maps: blood volume, bloodmore » flow and mean transit time. The variability of texture parameters was tested with respect to non-standardizable perfusion computation factors (noise level and artery contouring) using intraclass correlation coefficients (ICC). The parameter with the highest ICC in the correlated group of parameters (inter-parameter Spearman correlations) was tested for its predictive value. The final model to predict tumor control was built using multivariate Cox regression analysis with backward selection of the variables. For comparison, a predictive model based on tumor volume was created. Results: Ten parameters were found to be stable in both HNC and lung cancer regarding potentially non-standardizable factors after the correction for inter-parameter correlations. In the multivariate backward selection of the variables, blood flow entropy showed a highly significant impact on tumor control (p=0.03) with concordance index (CI) of 0.76. Blood flow entropy was significantly lower in the patient group with controlled tumors at 18 months (p<0.1). The new model showed a higher concordance index compared to the tumor volume model (CI=0.68). Conclusion: The preselection of variables in the robustness study allowed building a predictive radiomics-based model of tumor control in HNC despite a small patient cohort. This model was found to be superior to the volume-based model. The project was supported by the KFSP Tumor Oxygenation of the University of Zurich, by a grant of the Center for Clinical Research, University and University Hospital Zurich and by a research grant from Merck (Schweiz) AG.« less
Effects of back posture education on elementary schoolchildren's back function.
Geldhof, Elisabeth; Cardon, Greet; De Bourdeaudhuij, Ilse; Danneels, Lieven; Coorevits, Pascal; Vanderstraeten, Guy; De Clercq, Dirk
2007-06-01
The possible effects of back education on children's back function were never evaluated. Therefore, main aim of the present study was to evaluate the effects of back education in elementary schoolchildren on back function parameters. Since the reliability of back function measurement in children is poorly defined, another objective was to test the selected instruments for reliability in 8-11-year olds. The multi-factorial intervention lasting two school-years consisted of a back education program and the stimulation of postural dynamism in the class. Trunk muscle endurance, leg muscle capacity and spinal curvature were evaluated in a pre-post design including 41 children who received the back education program (mean age at post-test: 11.2 +/- 0.9 years) and 28 controls (mean age at post-test: 11.4 +/- 0.6 years). Besides, test-retest reliability with a 1-week interval was investigated in a separate sample. Therefore, 47 children (mean age: 10.1 +/- 0.5 years) were tested for reliability of trunk muscle endurance and 40 children (mean age: 10.2 +/- 0.7 years) for the assessment of spinal curvatures. Reliability of endurance testing was very good to good for the trunk flexors (ICC = 0.82) and trunk extensors (ICC = 0.63). The assessment of the thoracic (ICC = 0.69) and the lumbar curvature (ICC = 0.52) in seating position showed good to acceptable reliability. Low ICCs were found for the assessment of the thoracic (ICC = 0.39) and the lumbar curvature (ICC = 0.37) in stance. The effects of 2 year back education showed an increase in trunk flexor endurance in the intervention group compared to a decrease in the controls and a trend towards significance for a higher increase in trunk extensor endurance in the intervention group. For leg muscle capacity and spinal curvature no intervention effects were found. The small samples recommend cautious interpretation of intervention effects. However, the present study's findings favor the implementation of back education with focus on postural dynamism in the class as an integral part of the elementary school curriculum in the scope of optimizing spinal loading through the school environment.
Introduction of software tools for epidemiological surveillance in infection control in Colombia
Motoa, Gabriel; Vallejo, Marta; Blanco, Víctor M; Correa, Adriana; de la Cadena, Elsa; Villegas, María Virginia
2015-01-01
Introduction: Healthcare-Associated Infections (HAI) are a challenge for patient safety in the hospitals. Infection control committees (ICC) should follow CDC definitions when monitoring HAI. The handmade method of epidemiological surveillance (ES) may affect the sensitivity and specificity of the monitoring system, while electronic surveillance can improve the performance, quality and traceability of recorded information. Objective: To assess the implementation of a strategy for electronic surveillance of HAI, Bacterial Resistance and Antimicrobial Consumption by the ICC of 23 high-complexity clinics and hospitals in Colombia, during the period 2012-2013. Methods: An observational study evaluating the introduction of electronic tools in the ICC was performed; we evaluated the structure and operation of the ICC, the degree of incorporation of the software HAI Solutions and the adherence to record the required information. Results: Thirty-eight percent of hospitals (8/23) had active surveillance strategies with standard criteria of the CDC, and 87% of institutions adhered to the module of identification of cases using the HAI Solutions software. In contrast, compliance with the diligence of the risk factors for device-associated HAIs was 33%. Conclusions: The introduction of ES could achieve greater adherence to a model of active surveillance, standardized and prospective, helping to improve the validity and quality of the recorded information. PMID:26309340
Introduction of software tools for epidemiological surveillance in infection control in Colombia.
Hernández-Gómez, Cristhian; Motoa, Gabriel; Vallejo, Marta; Blanco, Víctor M; Correa, Adriana; de la Cadena, Elsa; Villegas, María Virginia
2015-01-01
Healthcare-Associated Infections (HAI) are a challenge for patient safety in the hospitals. Infection control committees (ICC) should follow CDC definitions when monitoring HAI. The handmade method of epidemiological surveillance (ES) may affect the sensitivity and specificity of the monitoring system, while electronic surveillance can improve the performance, quality and traceability of recorded information. To assess the implementation of a strategy for electronic surveillance of HAI, Bacterial Resistance and Antimicrobial Consumption by the ICC of 23 high-complexity clinics and hospitals in Colombia, during the period 2012-2013. An observational study evaluating the introduction of electronic tools in the ICC was performed; we evaluated the structure and operation of the ICC, the degree of incorporation of the software HAI Solutions and the adherence to record the required information. Thirty-eight percent of hospitals (8/23) had active surveillance strategies with standard criteria of the CDC, and 87% of institutions adhered to the module of identification of cases using the HAI Solutions software. In contrast, compliance with the diligence of the risk factors for device-associated HAIs was 33%. The introduction of ES could achieve greater adherence to a model of active surveillance, standardized and prospective, helping to improve the validity and quality of the recorded information.
Maceira, Alicia M; Tuset-Sanchis, Luis; López-Garrido, Miguel; San Andres, Marta; López-Lereu, M Pilar; Monmeneu, Jose V; García-González, M Pilar; Higueras, Laura
2018-05-01
The measurement of myocardial deformation by strain analysis is an evolving tool to quantify regional and global myocardial function. To assess the feasibility and reproducibility of myocardial strain/strain rate measurements with magnetic resonance feature tracking (MR-FT) in healthy subjects and in patient groups. Prospective study. Sixty patients (20 hypertensives with left ventricular (LV) hypertrophy (H); 20 nonischemic dilated cardiomyopathy (D); 20 ischemic heart disease (I); as well as 20 controls (C) were included, 10 men and 10 women in each group. A 1.5T MR protocol including steady-state free precession (SSFP) cine sequences in the standard views and late enhancement sequences. LV volumes, mass, global and regional radial, circumferential, and longitudinal strain/strain rate were measured using CVI42 software. The analysis time was recorded. Intraobserver and interobserver agreement and intraclass correlation coefficients (ICC) were obtained for reproducibility assessment as well as differences according to gender and group of pertinence. Strain/strain rate analysis could be achieved in all subjects. The average analysis time was 14 ± 3 minutes. The average intraobserver ICC was excellent (ICC >0.90) for strain and good (ICC >0.75) for strain rate. Reproducibility of strain measurements was good to excellent (ICC >0.75) for all groups of subjects and both genders. Reproducibility of strain measurements was good for basal segments (ICC >0.75) and excellent for middle and apical segments (ICC >0.90). Reproducibility of strain rate measurements was moderate for basal segments (ICC >0.50) and good for middle and apical segments. MR-FT for strain/strain rate analysis is a feasible and highly reproducible technique. CVI42 FT analysis was equally feasible and reproducible in various pathologies and between genders. Better reproducibility was seen globally for middle and apical segments, which needs further clarification. 3 Technical Efficacy Stage 2 J. Magn. Reson. Imaging 2018;47:1415-1425. © 2017 International Society for Magnetic Resonance in Medicine.
The stem cell growth factor receptor KIT is not expressed on interstitial cells in bladder.
Gevaert, Thomas; Ridder, Dirk De; Vanstreels, Els; Daelemans, Dirk; Everaerts, Wouter; Aa, Frank Van Der; Pintelon, Isabel; Timmermans, Jean-Pierre; Roskams, Tania; Steiner, Clara; Neuhaus, Jochen
2017-06-01
The mast/stem cell growth factor receptor KIT has long been assumed to be a specific marker for interstitial cells of Cajal (ICC) in the bladder, with possible druggable perspectives. However, several authors have challenged the presence of KIT + ICC in recent years. The aim of this study was therefore to attempt to clarify the conflicting reports on KIT expression in the bladder of human beings, rat, mouse and guinea pig and to elucidate the possible role of antibody-related issues and interspecies differences in this matter. Fresh samples were obtained from human, rat, mouse and guinea pig cystectomies and processed for single/double immunohistochemistry/immunofluorescence. Specific antibodies against KIT, mast cell tryptase (MCT), anoctamin-1 (ANO1) and vimentin were used to characterize the cell types expressing KIT. Gut (jejunum) tissue was used as an external antibody control. Our results revealed KIT expression on mast cells but not on ICC in human, rat, mouse and guinea pig bladder. Parallel immunohistochemistry showed KIT expression on ICC in human, rat, mouse and guinea pig gut, which confirmed the selectivity of the KIT antibody clones. In conclusion, we have shown that KIT + cells in human, rat, mouse and guinea pig bladder are mast cells and not ICC. The present report is important as it opposes the idea that KIT + ICC are present in bladder. In this perspective, functional concepts of KIT + ICC being involved in sensory and/or motor aspects of bladder physiology should be revised. © 2016 The Authors. Journal of Cellular and Molecular Medicine published by John Wiley & Sons Ltd and Foundation for Cellular and Molecular Medicine.
Short- and Long-Term Sleep Stability in Insomniacs and Healthy Controls.
Gaines, Jordan; Vgontzas, Alexandros N; Fernandez-Mendoza, Julio; Basta, Maria; Pejovic, Slobodanka; He, Fan; Bixler, Edward O
2015-11-01
Assess the short- and long-term stability of sleep duration in patients with insomnia and normal-sleeping controls. Observational short-term and prospective studies. Sleep laboratory. Patients with insomnia (n = 150) and controls (n = 151) were recruited from the local community or sleep disorders clinic. A subsample of 95 men from the Penn State Adult Cohort (PSAC) were followed up 2.6 y after their initial visit. Participants underwent a physical examination and 8-h polysomnography (PSG) recording for 3 consecutive nights (controls and insomniacs), or 2 single nights separated by several years (PSAC). Intraclass correlation coefficients (ICCs) assessed the stability of the variables total sleep time (TST), sleep onset latency (SOL), and wake after sleep onset (WASO). We also examined persistence of the first-night classification of "short" versus "normal" sleep duration on subsequent nights. Stability of TST, SOL, and WASO based on 1 night were slight to moderate in both patients with insomnia (ICC = 0.37-0.57) and controls (ICC = 0.39-0.59), and became substantial to almost perfect when based on the average of 3 nights (ICC = 0.64-0.81). We observed similar degrees of stability for TST and WASO in the longitudinal sample, with moderate stability based on a single night and substantial stability based on both nights. In examining the persistence of "short" and "normal" sleep duration, 71.4% (controls), 74.7% (patients with insomnia), and 72.6% (longitudinal sample) of participants retained their first-night classifications over subsequent nights. Sleep duration variables, particularly total sleep time based on 3 consecutive nights in both patients with insomnia and controls or two single-night recordings separated by several years, are stable and reflect a person's habitual sleep. Furthermore, a single night in the laboratory may be useful for reliably classifying one's sleep duration. © 2015 Associated Professional Sleep Societies, LLC.
An overview of inverted colloidal crystal systems for tissue engineering.
João, Carlos Filipe C; Vasconcelos, Joana Marta; Silva, Jorge Carvalho; Borges, João Paulo
2014-10-01
Scaffolding is at the heart of tissue engineering but the number of techniques available for turning biomaterials into scaffolds displaying the features required for a tissue engineering application is somewhat limited. Inverted colloidal crystals (ICCs) are inverse replicas of an ordered array of monodisperse colloidal particles, which organize themselves in packed long-range crystals. The literature on ICC systems has grown enormously in the past 20 years, driven by the need to find organized macroporous structures. Although replicating the structure of packed colloidal crystals (CCs) into solid structures has produced a wide range of advanced materials (e.g., photonic crystals, catalysts, and membranes) only in recent years have ICCs been evaluated as devices for medical/pharmaceutical and tissue engineering applications. The geometry, size, pore density, and interconnectivity are features of the scaffold that strongly affect the cell environment with consequences on cell adhesion, proliferation, and differentiation. ICC scaffolds are highly geometrically ordered structures with increased porosity and connectivity, which enhances oxygen and nutrient diffusion, providing optimum cellular development. In comparison to other types of scaffolds, ICCs have three major unique features: the isotropic three-dimensional environment, comprising highly uniform and size-controllable pores, and the presence of windows connecting adjacent pores. Thus far, this is the only technique that guarantees these features with a long-range order, between a few nanometers and thousands of micrometers. In this review, we present the current development status of ICC scaffolds for tissue engineering applications.
López-Plaza, Diego; Juan-Recio, Casto; Barbado, David; Ruiz-Pérez, Iñaki; Vera-Garcia, Francisco J
2018-05-18
Although the Star Excursion Balance test (SEBT) has shown a good intrasession reliability, the intersession reliability of this test has not been deeply studied. Furthermore, there is an evident high influence of the lower limbs in the performance of the SEBT, so even if it has been used to measure core stability, it is possibly not the most suitable measurement. The aims of this study were to (1) to assess the absolute and relative between-session reliability of the SEBT and 2 novel variations of this test to assess trunk postural control while sitting, ie, the Star Excursion Sitting Test (SEST) and the Star Excursion Timing Test (SETT); and (2) to analyze the relationships between these 3 test scores. Correlational and reliability test-retest study. Controlled laboratory environment. Twenty-seven physically active men (age: 24.54 ± 3.05 years). Relative and absolute reliability of the SEBT, SEST, and SETT were calculated through the intraclass correlation coefficient (ICC) and standard error of measurement (SEM), respectively. A Pearson correlation analysis was carried out between the variables of the 3 tests. Maximum normalized reach distances were assessed for different SEBT and SEST directions. In addition, composite indexes were calculated for SEBT, SEST, and SETT. The SEBT (dominant leg: ICC = 0.87 [0.73-0.94], SEM = 2.12 [1.66-2.93]; nondominant leg: ICC = 0.74 [0.50-0.87], SEM = 3.23 [2.54-4.45]), SEST (ICC = 0.85 [0.68-0.92], SEM = 1.27 [1.03-1.80]), and SETT (ICC = 0.61 [0.30-0.80], SEM = 2.31 [1.82-3.17]) composite indexes showed moderate-to-high 1-month reliability. A learning effect was detected for some SEBT and SEST directions and for SEST and SETT composite indexes. No significant correlations were found between SEBT and its 2 variations (r ≤ .366; P > .05). A significant correlation was found between the SEST and SETT composite indexes (r = .520; P > .01). SEBT, SEST, and SETT are reliable field protocols to measure postural control. However, whereas the SEBT assesses postural control in single-leg stance, SEST and SETT provide trunk postural control measures with lower influence of the lower-limbs. To be determined. Copyright © 2018 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Robbrecht, Cedric; Claes, Steven; Cromheecke, Michiel; Mahieu, Peter; Kakavelakis, Kyriakos; Victor, Jan; Bellemans, Johan; Verdonk, Peter
2014-10-01
Post-operative widening of tibial and/or femoral bone tunnels is a common observation after ACL reconstruction, especially with soft-tissue grafts. There are no studies comparing tunnel widening in hamstring autografts versus tibialis anterior allografts. The goal of this study was to observe the difference in tunnel widening after the use of allograft vs. autograft for ACL reconstruction, by measuring it with a novel 3-D computed tomography based method. Thirty-five ACL-deficient subjects were included, underwent anatomic single-bundle ACL reconstruction and were evaluated at one year after surgery with the use of 3-D CT imaging. Three independent observers semi-automatically delineated femoral and tibial tunnel outlines, after which a best-fit cylinder was derived and the tunnel diameter was determined. Finally, intra- and inter-observer reliability of this novel measurement protocol was defined. In femoral tunnels, the intra-observer ICC was 0.973 (95% CI: 0.922-0.991) and the inter-observer ICC was 0.992 (95% CI: 0.982-0.996). In tibial tunnels, the intra-observer ICC was 0.955 (95% CI: 0.875-0.985). The combined inter-observer ICC was 0.970 (95% CI: 0.987-0.917). Tunnel widening was significantly higher in allografts compared to autografts, in the tibial tunnels (p=0.013) as well as in the femoral tunnels (p=0.007). To our knowledge, this novel, semi-automated 3D-computed tomography image processing method has shown to yield highly reproducible results for the measurement of bone tunnel diameter and area. This series showed a significantly higher amount of tunnel widening observed in the allograft group at one-year follow-up. Level II, Prospective comparative study. Copyright © 2014 Elsevier B.V. All rights reserved.
Sled, Elizabeth A.; Sheehy, Lisa M.; Felson, David T.; Costigan, Patrick A.; Lam, Miu; Cooke, T. Derek V.
2010-01-01
The objective of the study was to evaluate the reliability of frontal plane lower limb alignment measures using a landmark-based method by (1) comparing inter- and intra-reader reliability between measurements of alignment obtained manually with those using a computer program, and (2) determining inter- and intra-reader reliability of computer-assisted alignment measures from full-limb radiographs. An established method for measuring alignment was used, involving selection of 10 femoral and tibial bone landmarks. 1) To compare manual and computer methods, we used digital images and matching paper copies of five alignment patterns simulating healthy and malaligned limbs drawn using AutoCAD. Seven readers were trained in each system. Paper copies were measured manually and repeat measurements were performed daily for 3 days, followed by a similar routine with the digital images using the computer. 2) To examine the reliability of computer-assisted measures from full-limb radiographs, 100 images (200 limbs) were selected as a random sample from 1,500 full-limb digital radiographs which were part of the Multicenter Osteoarthritis (MOST) Study. Three trained readers used the software program to measure alignment twice from the batch of 100 images, with two or more weeks between batch handling. Manual and computer measures of alignment showed excellent agreement (intraclass correlations [ICCs] 0.977 – 0.999 for computer analysis; 0.820 – 0.995 for manual measures). The computer program applied to full-limb radiographs produced alignment measurements with high inter- and intra-reader reliability (ICCs 0.839 – 0.998). In conclusion, alignment measures using a bone landmark-based approach and a computer program were highly reliable between multiple readers. PMID:19882339
Christiansen, C; Abreu, B; Ottenbacher, K; Huffman, K; Masel, B; Culpepper, R
1998-08-01
This report describes a reliability study using a prototype computer-simulated virtual environment to assess basic daily living skills in a sample of persons with traumatic brain injury (TBI). The benefits of using virtual reality in training for situations where safety is a factor have been established in defense and industry, but have not been demonstrated in rehabilitation. Thirty subjects with TBI receiving comprehensive rehabilitation services at a residential facility. An immersive virtual kitchen was developed in which a meal preparation task involving multiple steps could be performed. The prototype was tested using subjects who completed the task twice within 7 days. The stability of performance was estimated using intraclass correlation coefficients (ICCs). The ICC value for total performance based on all steps involved in the meal preparation task was .73. When three items with low variance were removed the ICC improved to .81. Little evidence of vestibular optical side-effects was noted in the subjects tested. Adequate initial reliability exists to continue development of the environment as an assessment and training prototype for persons with brain injury.
ICCE Policy Statement on Network and Multiple Machine Software.
ERIC Educational Resources Information Center
International Council for Computers in Education, Eugene, OR.
Designed to provide educators with guidance for the lawful reproduction of computer software, this document contains suggested guidelines, sample forms, and several short articles concerning software copyright and license agreements. The initial policy statement calls for educators to provide software developers (or their agents) with a…
Munbodh, Reshma; Knisely, Jonathan Ps; Jaffray, David A; Moseley, Douglas J
2018-05-01
We present and evaluate a fully automated 2D-3D intensity-based registration framework using a single limited field-of-view (FOV) 2D kV radiograph and a 3D kV CBCT for 3D estimation of patient setup errors during brain radiotherapy. We evaluated two similarity measures, the Pearson correlation coefficient on image intensity values (ICC) and maximum likelihood measure with Gaussian noise (MLG), derived from the statistics of transmission images. Pose determination experiments were conducted on 2D kV radiographs in the anterior-posterior (AP) and left lateral (LL) views and 3D kV CBCTs of an anthropomorphic head phantom. In order to minimize radiation exposure and exclude nonrigid structures from the registration, limited FOV 2D kV radiographs were employed. A spatial frequency band useful for the 2D-3D registration was identified from the bone-to-no-bone spectral ratio (BNBSR) of digitally reconstructed radiographs (DRRs) computed from the 3D kV planning CT of the phantom. The images being registered were filtered accordingly prior to computation of the similarity measures. We evaluated the registration accuracy achievable with a single 2D kV radiograph and with the registration results from the AP and LL views combined. We also compared the performance of the 2D-3D registration solutions proposed to that of a commercial 3D-3D registration algorithm, which used the entire skull for the registration. The ground truth was determined from markers affixed to the phantom and visible in the CBCT images. The accuracy of the 2D-3D registration solutions, as quantified by the root mean squared value of the target registration error (TRE) calculated over a radius of 3 cm for all poses tested, was ICC AP : 0.56 mm, MLG AP : 0.74 mm, ICC LL : 0.57 mm, MLG LL : 0.54 mm, ICC (AP and LL combined): 0.19 mm, and MLG (AP and LL combined): 0.21 mm. The accuracy of the 3D-3D registration algorithm was 0.27 mm. There was no significant difference in mean TRE for the 2D-3D registration algorithms using a single 2D kV radiograph with similarity measure and image view point. There was no significant difference in mean TRE between ICC LL , MLG LL , ICC (AP and LL combined), MLG (AP and LL combined), and the 3D-3D registration algorithm despite the smaller FOV used for the 2D-3D registration. While submillimeter registration accuracy was obtained with both ICC and MLG using a single 2D kV radiograph, combining the results from the two projection views resulted in a significantly smaller (P≤0.05) mean TRE. Our results indicate that it is possible to achieve submillimeter registration accuracy with both ICC and MLG using either single or dual limited FOV 2D kV radiographs of the head in the AP and LL views. The registration accuracy suggests that the 2D-3D registration solutions presented are suitable for the estimation of patient setup errors not only during conventional brain radiation therapy, but also during stereotactic procedures and proton radiation therapy where tighter setup margins are required. © 2018 American Association of Physicists in Medicine.
Gray, Vicki L; Ivanova, Tanya D; Garland, S Jayne
2014-01-01
Knowing the reliability of the center of pressure (COP) is important for interpreting balance deficits post-stroke, especially when the balance deficits can necessitate the use of short duration trials. The novel aspect of this reliability study was to examine the center of pressure measures using two adjacent force platforms between and within sessions in stroke and controls. After stroke, it is important to understand the contribution of the paretic and non-paretic leg to the motor control of standing balance. Because there is a considerable body of knowledge on COP reliability on a single platform, we chose to examine reliability using two adjacent platforms which has not been examined previously in stroke. Twenty participants post-stroke and 22 controls performed an arm raise, load drop and quiet stance balance task while standing on two adjacent force platforms, on two separate days. Intraclass correlations coefficient (ICC2,1) and percentage standard error of measurement (SEM%) were calculated for COP velocity, ellipse area, anterior-posterior (AP) displacement, and medial-lateral (ML) displacement. Between sessions, COP velocity was the most reliable with high ICCs and low SEM% across groups and tasks and ellipse area was less reliable with low ICCs across groups and tasks. COP measures were less reliable during the arm raise than load drop post-stroke. Within session reliability was high for COP velocity and ML displacement requiring no more than six trials across tasks. The COP velocity was the most reliable measure with high ICCs between sessions and the high reliability was achieved with fewer trials in both groups in a single session. Copyright © 2014 Elsevier B.V. All rights reserved.
Troester, Jordan C; Jasmin, Jason G; Duffield, Rob
2018-06-01
The present study examined the inter-trial (within test) and inter-test (between test) reliability of single-leg balance and single-leg landing measures performed on a force plate in professional rugby union players using commercially available software (SpartaMARS, Menlo Park, USA). Twenty-four players undertook test - re-test measures on two occasions (7 days apart) on the first training day of two respective pre-season weeks following 48h rest and similar weekly training loads. Two 20s single-leg balance trials were performed on a force plate with eyes closed. Three single-leg landing trials were performed by jumping off two feet and landing on one foot in the middle of a force plate 1m from the starting position. Single-leg balance results demonstrated acceptable inter-trial reliability (ICC = 0.60-0.81, CV = 11-13%) for sway velocity, anterior-posterior sway velocity, and mediolateral sway velocity variables. Acceptable inter-test reliability (ICC = 0.61-0.89, CV = 7-13%) was evident for all variables except mediolateral sway velocity on the dominant leg (ICC = 0.41, CV = 15%). Single-leg landing results only demonstrated acceptable inter-trial reliability for force based measures of relative peak landing force and impulse (ICC = 0.54-0.72, CV = 9-15%). Inter-test results indicate improved reliability through the averaging of three trials with force based measures again demonstrating acceptable reliability (ICC = 0.58-0.71, CV = 7-14%). Of the variables investigated here, total sway velocity and relative landing impulse are the most reliable measures of single-leg balance and landing performance, respectively. These measures should be considered for monitoring potential changes in postural control in professional rugby union.
[Reliability and validity of a generic job exposure matrix applied on a small-business].
Haro-García, Luis; Celis-Quintal, Germán; López-Rojas, Pablo; Sánchez-Román, Francisco Raúl; Juárez-Pérez, Cuauhtémoc Arturo
2007-01-01
to evaluate the reliability and validity of a generic job exposure matrix (JEM) applied in a small business. procedures to evaluate a JEM integrated by six sections: the number of exposed workers per area, frequency of exposure, time of exposure time, level of exposure, safety controls, and proximity to source of exposure, was evaluated. The JEM also obtains information about possible health effects from exposure to occupational/environment agents. Two observers estimated the risk of exposure to epoxy resins on 31 workers of an epoxy resin facility in Mexico City. The rater agreements between the two observers were assessed through percent agreement (PA), weighted kappa (kappa(w)) and the intraclass correlation coefficient (ICC). disagreements were greater for the number of exposed workers (PA = 61.3, kappa(w) = 0.24, ICC = 0.33), level of exposure (PA= 66.7, kappa(w) = 0.25, ICC= 0.56), and safety controls (PA = 54.8, kappa(w) = 0.23, ICC = 0.69) sections. Percent agreement and kappa(w) were 64% and 0.58, respectively. In accordance with Landis and Koch, Altman, Fleiss, and Byrt classifications for the interpretation of kappa value, the weighted kappa (0.58) ranged from moderate to a fair good level. despite the discordance in some sections, the JEM proved to be useful to identify the risk of exposure in this type of small business.
The identification of specialized pacemaking cells in the anal sphincters.
Shafik, Ahmed; El Sibai, Olfat; Ahmed, Ismail
2006-07-01
Interstitial cells of Cajal (ICC) are claimed to generate the electrical activity in the colon and stomach. As the external (EAS) and internal (IAS) anal sphincters exhibit resting electrical activity, we hypothesized the presence of ICC in these sphincters. This hypothesis was investigated in the current study. Specimens from the EAS and IAS were taken from normal areas of the anorectum which had been surgically excised by abdominoperineal operation for rectal cancer of 28 patients (16 men, 12 women, mean age 42.2+/-4.8 years). The specimens were subjected to c-kit immunohistochemistry. Controls for the specificity of the antisera consisted of tissue incubation with normal rabbit serum substituted for the primary antiserum. Fusiform, c-kit positive, ICC-like cells were detected in the anal sphincters; they had dendritic processes. They were clearly distinguishable from the non-branching, c-kit negative smooth and striated muscle cells of the anal sphincters. The specimens contained also c-kit positive mast cells, but they had a rounded body with no dendritic processes. Immunoreactivity was absent in negative controls in which the primary antibody was omitted. We have identified, for the first time, cells in EAS and IAS with morphological and immunological phenotypes similar to ICCs of the gut. These cells appear to be responsible for initiating the slow waves recorded from the anal sphincters and for controlling their activity. A deficiency or absence of these cells may affect the anal motile activity. Studies are needed to explore the role of these cells in anal motility disorders.
A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research.
Koo, Terry K; Li, Mae Y
2016-06-01
Intraclass correlation coefficient (ICC) is a widely used reliability index in test-retest, intrarater, and interrater reliability analyses. This article introduces the basic concept of ICC in the content of reliability analysis. There are 10 forms of ICCs. Because each form involves distinct assumptions in their calculation and will lead to different interpretations, researchers should explicitly specify the ICC form they used in their calculation. A thorough review of the research design is needed in selecting the appropriate form of ICC to evaluate reliability. The best practice of reporting ICC should include software information, "model," "type," and "definition" selections. When coming across an article that includes ICC, readers should first check whether information about the ICC form has been reported and if an appropriate ICC form was used. Based on the 95% confident interval of the ICC estimate, values less than 0.5, between 0.5 and 0.75, between 0.75 and 0.9, and greater than 0.90 are indicative of poor, moderate, good, and excellent reliability, respectively. This article provides a practical guideline for clinical researchers to choose the correct form of ICC and suggests the best practice of reporting ICC parameters in scientific publications. This article also gives readers an appreciation for what to look for when coming across ICC while reading an article.
Reliability of a rapid hematology stain for sputum cytology*
Gonçalves, Jéssica; Pizzichini, Emilio; Pizzichini, Marcia Margaret Menezes; Steidle, Leila John Marques; Rocha, Cristiane Cinara; Ferreira, Samira Cardoso; Zimmermann, Célia Tânia
2014-01-01
Objective: To determine the reliability of a rapid hematology stain for the cytological analysis of induced sputum samples. Methods: This was a cross-sectional study comparing the standard technique (May-Grünwald-Giemsa stain) with a rapid hematology stain (Diff-Quik). Of the 50 subjects included in the study, 21 had asthma, 19 had COPD, and 10 were healthy (controls). From the induced sputum samples collected, we prepared four slides: two were stained with May-Grünwald-Giemsa, and two were stained with Diff-Quik. The slides were read independently by two trained researchers blinded to the identification of the slides. The reliability for cell counting using the two techniques was evaluated by determining the intraclass correlation coefficients (ICCs) for intraobserver and interobserver agreement. Agreement in the identification of neutrophilic and eosinophilic sputum between the observers and between the stains was evaluated with kappa statistics. Results: In our comparison of the two staining techniques, the ICCs indicated almost perfect interobserver agreement for neutrophil, eosinophil, and macrophage counts (ICC: 0.98-1.00), as well as substantial agreement for lymphocyte counts (ICC: 0.76-0.83). Intraobserver agreement was almost perfect for neutrophil, eosinophil, and macrophage counts (ICC: 0.96-0.99), whereas it was moderate to substantial for lymphocyte counts (ICC = 0.65 and 0.75 for the two observers, respectively). Interobserver agreement for the identification of eosinophilic and neutrophilic sputum using the two techniques ranged from substantial to almost perfect (kappa range: 0.91-1.00). Conclusions: The use of Diff-Quik can be considered a reliable alternative for the processing of sputum samples. PMID:25029648
Baker, Salah A; Drumm, Bernard T; Saur, Dieter; Hennig, Grant W; Ward, Sean M; Sanders, Kenton M
2016-06-15
Interstitial cells of Cajal at the level of the deep muscular plexus (ICC-DMP) in the small intestine generate spontaneous Ca(2+) transients that consist of localized Ca(2+) events and limited propagating Ca(2+) waves. Ca(2+) transients in ICC-DMP display variable characteristics: from discrete, highly localized Ca(2+) transients to regionalized Ca(2+) waves with variable rates of occurrence, amplitude, duration and spatial spread. Ca(2+) transients fired stochastically, with no cellular or multicellular rhythmic activity being observed. No correlation was found between the firing sites in adjacent cells. Ca(2+) transients in ICC-DMP are suppressed by the ongoing release of inhibitory neurotransmitter(s). Functional intracellular Ca(2+) stores are essential for spontaneous Ca(2+) transients, and the sarco/endoplasmic reticulum Ca(2+) -ATPase (SERCA) pump is necessary for maintenance of spontaneity. Ca(2+) release mechanisms involve both ryanodine receptors (RyRs) and inositol triphosphate receptors (InsP3 Rs). Release from these channels is interdependent. ICC express transcripts of multiple RyRs and InsP3 Rs, with Itpr1 and Ryr2 subtypes displaying the highest expression. Interstitial cells of Cajal in the deep muscular plexus of the small intestine (ICC-DMP) are closely associated with varicosities of enteric motor neurons and generate responses contributing to neural regulation of intestinal motility. Responses of ICC-DMP are mediated by activation of Ca(2+) -activated Cl(-) channels; thus, Ca(2+) signalling is central to the behaviours of these cells. Confocal imaging was used to characterize the nature and mechanisms of Ca(2+) transients in ICC-DMP within intact jejunal muscles expressing a genetically encoded Ca(2+) indicator (GCaMP3) selectively in ICC. ICC-DMP displayed spontaneous Ca(2+) transients that ranged from discrete, localized events to waves that propagated over variable distances. The occurrence of Ca(2+) transients was highly variable, and it was determined that firing was stochastic in nature. Ca(2+) transients were tabulated in multiple cells within fields of view, and no correlation was found between the events in adjacent cells. TTX (1 μm) significantly increased the occurrence of Ca(2+) transients, suggesting that ICC-DMP contributes to the tonic inhibition conveyed by ongoing activity of inhibitory motor neurons. Ca(2+) transients were minimally affected after 12 min in Ca(2+) free solution, indicating these events do not depend immediately upon Ca(2+) influx. However, inhibitors of sarco/endoplasmic reticulum Ca(2+) -ATPase (SERCA) pump and blockers of inositol triphosphate receptor (InsP3 R) and ryanodine receptor (RyR) channels blocked ICC Ca(2+) transients. These data suggest an interdependence between RyR and InsP3 R in the generation of Ca(2+) transients. Itpr1 and Ryr2 were the dominant transcripts expressed by ICC. These findings provide the first high-resolution recording of the subcellular Ca(2+) dynamics that control the behaviour of ICC-DMP in situ. © 2016 The Authors. The Journal of Physiology © 2016 The Physiological Society.
Short- and Long-Term Sleep Stability in Insomniacs and Healthy Controls
Gaines, Jordan; Vgontzas, Alexandros N.; Fernandez-Mendoza, Julio; Basta, Maria; Pejovic, Slobodanka; He, Fan; Bixler, Edward O.
2015-01-01
Study Objectives: Assess the short- and long-term stability of sleep duration in patients with insomnia and normal-sleeping controls. Design: Observational short-term and prospective studies. Setting: Sleep laboratory. Participants: Patients with insomnia (n = 150) and controls (n = 151) were recruited from the local community or sleep disorders clinic. A subsample of 95 men from the Penn State Adult Cohort (PSAC) were followed up 2.6 y after their initial visit. Measurements: Participants underwent a physical examination and 8-h polysomnography (PSG) recording for 3 consecutive nights (controls and insomniacs), or 2 single nights separated by several years (PSAC). Intraclass correlation coefficients (ICCs) assessed the stability of the variables total sleep time (TST), sleep onset latency (SOL), and wake after sleep onset (WASO). We also examined persistence of the first-night classification of “short” versus “normal” sleep duration on subsequent nights. Results: Stability of TST, SOL, and WASO based on 1 night were slight to moderate in both patients with insomnia (ICC = 0.37–0.57) and controls (ICC = 0.39–0.59), and became substantial to almost perfect when based on the average of 3 nights (ICC = 0.64–0.81). We observed similar degrees of stability for TST and WASO in the longitudinal sample, with moderate stability based on a single night and substantial stability based on both nights. In examining the persistence of “short” and “normal” sleep duration, 71.4% (controls), 74.7% (patients with insomnia), and 72.6% (longitudinal sample) of participants retained their first-night classifications over subsequent nights. Conclusions: Sleep duration variables, particularly total sleep time based on 3 consecutive nights in both patients with insomnia and controls or two single-night recordings separated by several years, are stable and reflect a person's habitual sleep. Furthermore, a single night in the laboratory may be useful for reliably classifying one's sleep duration. Citation: Gaines J, Vgontzas AN, Fernandez-Mendoza J, Basta M, Pejovic S, He F, Bixler EO. Short- and long-term sleep stability in insomniacs and healthy controls. SLEEP 2015;38(11):1727–1734. PMID:26237768
Miyamoto-Kikuta, Sachiko; Ezaki, Taichi; Komuro, Terumasa
2009-10-01
The guinea-pig ileocaecal junction including the valve was studied by immunohistochemistry to clarify the organization of the muscle bundles, the enteric nerves and the interstitial cells of Cajal (ICC). This region clearly exhibited characteristic features in the distribution patterns of ICC in a proximal to distal direction: (1) the thickened portion of the terminal ileum immediately adjacent to the ileocecal junction contained many ICC throughout the circular (ICC-CM) and longitudinal (ICC-LM) muscle layers, but ICC were few or absent in the rest of the ileum; (2) the ileal side of the valve contained ICC associated with the deep muscular plexus (ICC-DMP) as in the small intestine, whereas ICC-DMP were absent in the caecal side as in the caecum; (3) the valve contained many ICC-CM and ICC-LM in both the ileal and caecal sides; (4) many ICC associated with the myenteric plexus were observed in both the ileal and caecal sides of the valve, whereas they were only sparsely found in the caecum; (5) ICC were also observed around the submucosal plexus in a confined area of the terminal ileum and the ileocaecal valve. These observations provide morphological evidence that the terminal ileum and ileocaecal valve are specially equipped for their active involvement in the movement of the junctional area.
Gong, Yaoyao; Huang, Lei; Cheng, Wenfang; Li, Xueliang; Lu, Jia; Lin, Lin; Si, Xinmin
2014-01-01
Interstitial cells of Cajal (ICC) are pacemaker cells in the gastrointestinal (GI) tract and loss of ICC is associated with many GI motility disorders. Previous studies have shown that ICC have the capacity to regenerate or restore, and several growth factors are critical to their growth, maintenance or regeneration. The present study aimed to investigate the roles of interleukin-9 (IL-9) in the growth, maintenance and pacemaker functions of cultured ICC. Here, we report that IL-9 promotes proliferation of ICC, and culturing ICC with IL-9 enhances cholecystokinin-8-induced Ca²⁺ transients, which is probably caused by facilitating maintenance of ICC functions under culture condition. We also show co-localizations of cholecystokinin-1 receptor and IL-9 receptor with c-kit by double-immunohistochemical labeling. In conclusion, IL-9 can promote ICC growth and help maintain ICC functions; IL-9 probably performs its functions via IL-9 receptors on ICC.
The International Criminal Court’s First Years: Stumbling Toward Justice
2012-03-20
person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control... current U.S. policy of engagement with the ICC and Assembly of States Parties (ASP) to the RS provides the best opportunity for continued development...credibility and relevance of the court was sorely tested. The current U.S. policy of engagement with the ICC and Assembly of States Parties (ASP) to
Collins, Clinton; Klausner, Adam P; Herrick, Benjamin; Koo, Harry P; Miner, Amy S; Henderson, Scott C; Ratz, Paul H
2009-01-01
Interstitial cells of Cajal (ICCs) have been identified as pacemaker cells in the upper urinary tract and urethra, but the role of ICCs in the bladder remains to be determined. We tested the hypotheses that ICCs express cyclooxygenase (COX), and that COX products (prostaglandins), are the cause of spontaneous rhythmic contraction (SRC) of isolated strips of rabbit bladder free of urothelium. SRC was abolished by 10 μM indomethacin and ibuprofen (non-selective COX inhibitors). SRC was concentration-dependently inhibited by selective COX-1 (SC-560 and FR-122047) and COX-2 inhibitors (NS-398 and LM-1685), and by SC-51089, a selective antagonist for the PGE-2 receptor (EP) and ICI-192,605 and SQ-29,548, selective antagonists for thromboxane receptors (TP). The partial agonist/antagonist of the PGF-2α receptor (FP), AL-8810, inhibited SRC by ∼50%. Maximum inhibition was ∼90% by SC-51089, ∼80–85% by the COX inhibitors and ∼70% by TP receptor antagonists. In the presence of ibuprofen to abolish SRC, PGE-2, sulprostone, misoprostol, PGF-2α and U-46619 (thromboxane mimetic) caused rhythmic contractions that mimicked SRC. Fluorescence immunohistochemistry coupled with confocal laser scanning microscopy revealed that c-Kit and vimentin co-localized to interstitial cells surrounding detrusor smooth muscle bundles, indicating the presence of extensive ICCs in rabbit bladder. Co-localization of COX-1 and vimentin, and COX-2 and vimentin by ICCs supports the hypothesis that ICCs were the predominant cell type in rabbit bladder expressing both COX isoforms. These data together suggest that ICCs appear to be an important source of prostaglandins that likely play a role in regulation of SRC. Additional studies on prostaglandin-dependent SRC may generate opportunities for the application of novel treatments for disorders leading to overactive bladder. PMID:19243470
Norte, Grant E; Frye, Jamie L; Hart, Joseph M
2015-11-01
The superimposed-burst (SIB) technique is commonly used to quantify central activation failure after knee-joint injury, but its reliability has not been established in pathologic cohorts. To assess within-session and between-sessions reliability of the SIB technique in patients with patellofemoral pain. Descriptive laboratory study. University laboratory. A total of 10 patients with self-reported patellofemoral pain (1 man, 9 women; age = 24.1 ± 3.8 years, height = 167.8 ± 15.2 cm, mass = 71.6 ± 17.5 kg) and 10 healthy control participants (3 men, 7 women; age = 27.4 ± 5.0 years, height = 173.5 ± 9.9 cm, mass = 78.2 ± 16.5 kg) volunteered. Participants were assessed at 6 intervals spanning 21 days. Intraclass correlation coefficients (ICCs [3,3]) were used to assess reliability. Quadriceps central activation ratio, knee-extension maximal voluntary isometric contraction force, and SIB force. The quadriceps central activation ratio was highly reliable within session (ICC [3,3] = 0.97) and between sessions through day 21 (ICC [3,3] = 0.90-0.95). Acceptable reliability of knee extension (ICC [3,3] = 0.75-0.91) and SIB force (ICC [3,3] = 0.77-0.89) was observed through day 21. The SIB technique was reliable for clinical research up to 21 days in patients with patellofemoral pain.
IDH mutations in liver cell plasticity and biliary cancer
Saha, Supriya K; Parachoniak, Christine A; Bardeesy, Nabeel
2014-01-01
Intrahepatic cholangiocarcinoma (ICC) is an aggressive cancer associated with the bile ducts within the liver. These tumors are characterized by frequent gain-of-function mutations in the isocitrate dehydrogenase 1 and 2 (IDH1 and IDH2) genes—that are also common in subsets of neural, haematopoietic and bone tumors, but rare or absent in the other types of gastrointestinal malignancy. Mutant IDH acts through a novel mechanism of oncogenesis, producing high levels of the metabolite 2-hydroxyglutarate, which interferes with the function of α-ketoglutarate-dependent enzymes that regulate diverse cellular processes including histone demethylation and DNA modification. Recently, we used in vitro stem cell systems and genetically engineered mouse models (GEMMs) to demonstrate that mutant IDH promotes ICC formation by blocking hepatocyte differentiation and increasing pools of hepatic progenitors that are susceptible to additional oncogenic hits leading to ICC. We found that silencing of HNF4A—encoding a master transcriptional regulator of hepatocyte identity and quiescence—was critical to mutant IDH-mediated inhibition of liver differentiation. In line with these findings, human ICC with IDH mutations are characterized by a hepatic progenitor cell transcriptional signature suggesting that they are a distinct ICC subtype as compared to IDH wild type tumors. The role of mutant IDH in controlling hepatic differentiation state suggests the potential of newly developed inhibitors of the mutant enzyme as a form of differentiation therapy in a solid tumor. PMID:25485496
Healthons: errorless healthcare with bionic hugs and no need for quality control.
Bushko, Renata G
2005-01-01
Errorless, invisible, continuous and infrastructure-free healthcare should become our goal. In order to achieve that goal, we need to rapidly move from current episodic and emergency-driven "healthcare delivery system" to an intelligent and extelligent health environment. That requires introduction of distributed affective Intelligent Caring Creatures (ICCs) consisting of healthons. Healthons are tools combining prevention with diagnosis and treatment based on continuous monitoring and analyzing of vital signs and biochemistry. Unlike humans, who posses only two or three dimensions of thinking, healthons can assure errorless health because of their adaptability, flexibility, and multidimensional reasoning capability. ICCs can do "the right thing" based on (1) state-of-art medical knowledge, (2) data about emotional, physiological, and genetic state of a consumer and (3) moral values of a consumer. The transition to the intelligent health environment based on ICCs requires the solutions to many currently unsolved healthcare problems. This paper lists the unsolved problems (by analogy to mathematical unsolved problems list) and explains why errorless healthcare with bionic hugs and no need for quality control is possible.
Cheung, Gordon; Goonewardene, Mithran Suresh; Islam, Syed Mohammed Shamsul; Murray, Kevin; Koong, Bernard
2013-05-01
To assess the validity of using jugale (J) and Antegonion (Ag) on Posterior-Anterior cephalograms (PAC) as landmarks for transverse intermaxillary analysis when compared with Cone Beam Computed Tomography (CBCT). Conventional PAC and CBCT images were taken of 28 dry skulls. Craniometric measurements between the bilateral landmarks, Antegonion and Jugale, were obtained from the skulls using a microscribe and recorded as the base standard. The corresponding andmarks were identified and measured on CBCT and PAC and compared with the base standard measurements. The accuracy and reliability of the measurements were statistically evaluated and the validity was assessed by comparing the ability of the two image modalities to accurately diagnose an arbitrarily selected J-J/Ag-Ag ratio. All measurements were repeated at least 7 weeks apart. Intra-class correlations (ICC) and Bland-Altman plots were used to analyse the data. All three methods were shown to be reliable as all had a mean error of less than 0.5 mm between repeated measurements. When compared with the base standard, CBCT measurements were shown to have higher agreement (ICC: 0.861-0.964) compared with measurements taken from PAC (ICC: 0.794-0.796). When the arbitrary J-J/Ag-Ag ratio was assessed, 18 per cent of cases were incorrectly diagnosed with a transverse discrepancy on the PAC compared with the CBCT which incorrectly diagnosed 8.7 per cent. CBCT was shown to be more reliable in assessing intermaxillary transverse discrepancy compared with PAC when using J-J/Ag-Ag ratios.
Echegaray, Sebastian; Nair, Viswam; Kadoch, Michael; Leung, Ann; Rubin, Daniel; Gevaert, Olivier; Napel, Sandy
2016-12-01
Quantitative imaging approaches compute features within images' regions of interest. Segmentation is rarely completely automatic, requiring time-consuming editing by experts. We propose a new paradigm, called "digital biopsy," that allows for the collection of intensity- and texture-based features from these regions at least 1 order of magnitude faster than the current manual or semiautomated methods. A radiologist reviewed automated segmentations of lung nodules from 100 preoperative volume computed tomography scans of patients with non-small cell lung cancer, and manually adjusted the nodule boundaries in each section, to be used as a reference standard, requiring up to 45 minutes per nodule. We also asked a different expert to generate a digital biopsy for each patient using a paintbrush tool to paint a contiguous region of each tumor over multiple cross-sections, a procedure that required an average of <3 minutes per nodule. We simulated additional digital biopsies using morphological procedures. Finally, we compared the features extracted from these digital biopsies with our reference standard using intraclass correlation coefficient (ICC) to characterize robustness. Comparing the reference standard segmentations to our digital biopsies, we found that 84/94 features had an ICC >0.7; comparing erosions and dilations, using a sphere of 1.5-mm radius, of our digital biopsies to the reference standard segmentations resulted in 41/94 and 53/94 features, respectively, with ICCs >0.7. We conclude that many intensity- and texture-based features remain consistent between the reference standard and our method while substantially reducing the amount of operator time required.
Exploration and Evaluation of Nanometer Low-power Multi-core VLSI Computer Architectures
2015-03-01
ICC, the Milkway database was created using the command: milkyway –galaxy –nogui –tcl –log memory.log one.tcl As stated previously, it is...EDA tools. Typically, Synopsys® tools use Milkway databases, whereas, Cadence Design System® use Layout Exchange Format (LEF) formats. To help
Gröger, Dominic; Paulus, Florian; Licha, Kai; Welker, Pia; Weinhart, Marie; Holzhausen, Cornelia; Mundhenk, Lars; Gruber, Achim D; Abram, Ulrich; Haag, Rainer
2013-09-18
Herein we describe a platform technology for the synthesis and characterization of partially aminated, (35)S-labeled, dendritic polyglycerol sulfate (dPG(35)S amine) and fluorescent dPGS indocarbocyanine (ICC) dye conjugates. These polymer conjugates, based on a biocompatible dendritic polyglycerol scaffold, exhibit a high affinity to inflamed tissue in vivo and represent promising candidates for therapeutic and diagnostic applications. By utilizing a one-step sequential copolymerization approach, dendritic polyglycerol (Mn ≈ 4.5 kDa) containing 9.4% N-phthalimide protected amine functionalities was prepared on a large scale. Sulfation and simultaneous radio labeling with (35)SO3 pyridine complex, followed by cleavage of the N-phthalimide protecting groups, yielded dPG(35)S amine as a beta emitting, inflammation specific probe with free amino functionalities for conjugation. Furthermore, efficient labeling procedures with ICC via iminothiolane modification and subsequent "Michael" addition of the maleimide functionalized ICC dye, as well as by amide formation via NHS derivatized ICC on a dPGS amine scaffold, are described. The dPGS-ICC conjugates were investigated with respect to their photophysical properties, and both the radiolabeled and fluorescent compounds were comparatively visualized in histological tissue sections (radio detection and fluorescence microscopy) of animals treated with dPGS. Furthermore, cellular uptake of dPGS-ICC was found in endothelial cord blood (HUVEC) and the epithelial lung cells (A549). The presented synthetic routes allow a reproducible, controlled synthesis of dPGS amine on kilogram scale applying a one-pot batch reaction process. dPGS amine can be used for analysis via radioactivity or fluorescence, thereby creating a new platform for inflammation specific, multimodal imaging purposes using other attachable probes or contrast agents.
Li, Weiying; Zhang, Junpeng; Wang, Feng; Qian, Lin; Zhou, Yanyan; Qi, Wanqi; Chen, Jiping
2018-07-01
Public health is threatened by deteriorated water quality due to bacterial regrowth and uncontrolled growth-related problems in drinking water distribution systems (DWDSs). To investigate the scope of this problem, a two-year field study was conducted in south China. The amount of assimilable organic carbon (AOC), total cell concentrations (TCC), and intact cell concentrations (ICC) of water samples were determined by flow cytometry. The results indicated that ICC was significantly correlated to AOC concentration when the chlorine concentration was less than 0.15 mg/L, and ICC was lower at chlorine concentrations greater than 0.15 mg/L, suggesting that free chlorine level had effect on AOC and ICC. To further analyze the effect of disinfectant on AOC and bacterial growth, we designed an orthogonal experiment with different dosages of two commonly used disinfectants, chlorine and chloramine. The results demonstrated that high concentrations of free chlorine (>0.15 mg/L) and chloramine (>0.4 mg/L) were associated with relatively low proportions of intact cells and cultivable bacteria. Compared with chlorine, chloramine tended to cause lower AOC level and intact cells, likely because the chlorinated disinfection byproducts (DBPs) were more easily absorbed by bacteria than the chloraminated DBPs. Based on the statistical analysis of 240 water samples, ICC was limited when AOC concentration was less than 135 μg/L, while temperature and the number of small-size particles showed positive effects on ICC (P<0.05). We conclude that the use of chloramine and controlling particle numbers should be suitable strategies to limit bacterial regrowth. Copyright © 2018 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Brese, Falk; Jung, Michael; Mirazchiyski, Plamen; Schulz, Wolfram; Zuehlke, Olaf
2011-01-01
This document presents Supplement 1 of "The International Civic and Citizenship Education Study (ICCS) 2009 International Database," which includes data for all questionnaires administered as part of the ICCS 2009 assessment. This supplement contains the international version of the ICCS 2009 questionnaires in the following seven…
Palmer, Kara K.
2017-01-01
Assessing children’s perceptions of their movement abilities (i.e., perceived competence) is traditionally done using picture scales—Pictorial Scale of Perceived Competence and Acceptance for Young Children or Pictorial Scale of Perceived Movement Skill Competence. Pictures fail to capture the temporal components of movement. To address this limitation, we created a digital-based instrument to assess perceived motor competence: the Digital Scale of Perceived Motor Competence. The purpose of this study was to determine the validity, reliability, and internal consistency of the Digital-based Scale of Perceived Motor Skill Competence. The Digital-based Scale of Perceived Motor Skill Competence is based on the twelve fundamental motor skills from the Test of Gross Motor Development-2nd Edition with a similar layout and item structure as the Pictorial Scale of Perceived Movement Skill Competence. Face Validity of the instrument was examined in Phase I (n = 56; Mage = 8.6 ± 0.7 years, 26 girls). Test-retest reliability and internal consistency were assessed in Phase II (n = 54, Mage = 8.7 years ± 0.5 years, 26 girls). Intra-class correlations (ICC) and Cronbach’s alpha were conducted to determine test-retest reliability and internal consistency for all twelve skills along with locomotor and object control subscales. The Digital Scale of Perceived Motor Competence demonstrates excellent test-retest reliability (ICC = 0.83, total; ICC = 0.77, locomotor; ICC = 0.79, object control) and acceptable/good internal consistency (α = 0.62, total; α = 0.57, locomotor; α = 0.49, object control). Findings provide evidence of the reliability of the three level digital-based instrument of perceived motor competence for older children. PMID:29910408
Clifford, Gary M; Franceschi, Silvia; Keiser, Olivia; Schöni-Affolter, Franziska; Lise, Mauro; Dehler, Silvia; Levi, Fabio; Mousavi, Mohsen; Bouchardy, Christine; Wolfensberger, Aline; Darling, Katharine E; Staehelin, Cornelia; Bertisch, Barbara; Kuenzli, Esther; Bernasconi, Enos; Pawlita, Michael; Egger, Matthias
2016-04-01
HIV-infected women are at increased risk of cervical intraepithelial neoplasia (CIN) and invasive cervical cancer (ICC), but it has been difficult to disentangle the influences of heavy exposure to HPV infection, inadequate screening and immunodeficiency. A case-control study including 364 CIN2/3 and 20 ICC cases matched to 1,147 controls was nested in the Swiss HIV Cohort Study (1985-2013). CIN2/3 risk was significantly associated with low CD4+ cell counts, whether measured as nadir [odds ratio (OR) per 100-cell/μL decrease = 1.15, 95% CI: 1.08, 1.22], or at CIN2/3 diagnosis (1.10, 95% CI: 1.04, 1.16). An association was evident even for nadir CD4+ 200-349 versus ≥350 cells/μL (OR = 1.57, 95% CI: 1.09, 2.25). After adjustment for nadir CD4+, a protective effect of >2-year cART use was seen against CIN2/3 (OR versus never cART use = 0.64, 95% CI: 0.42, 0.98). Despite low study power, similar associations were seen for ICC, notably with nadir CD4+ (OR for 50 vs. >350 cells/μL= 11.10, 95% CI: 1.24, 100). HPV16-L1 antibodies were significantly associated with CIN2/3, but HPV16-E6 antibodies were nearly exclusively detected in ICC. In conclusion, worsening immunodeficiency, even at only moderately decreased CD4+ cell counts, is a significant risk factor for CIN2/3 and cervical cancer. © 2015 UICC.
Michiels, Sarah; De Hertogh, Willem; Truijen, Steven; November, Danny; Wuyts, Floris; Van de Heyning, Paul
2013-05-01
Cervical sensorimotor control (CSMC) becomes increasingly important in the assessment and treatment of patients with neck pain. This review aims to compare commonly used CSMC measuring methods in terms of required tasks, measuring device and clinimetric properties. A systematic review of two databases, followed by methodological quality assessment (CBO guidelines). The methodological quality of 34 included articles was generally good (five to seven out of eight), the inter-rater agreement was excellent (κw=0.966, p<0.01). Following tasks were found: head repositioning accuracy to the neutral head position (HRA-to-NHP) and to a target position (HRA-to-target), a virtual reality test, a continuous linear movement technique (CLMT) and an object following non-linear movement technique (NLMT) (The Fly™). Test-retest reliability was fair to excellent (ICC 0.35-0.87) for the HRA-to-NHP, very bad to excellent (ICC 0.01-0.90) for the HRA-to-target, fair to good (ICC 0.25-0.77) for the virtual reality test and moderate to excellent (ICC: 0.60-0.86) for The Fly™. The reliability of the CLMT was not documented. The HRA-to-NHP, The Fly™ and the CLMT can discriminate between patients with neck complaints and controls (discriminant validity). Currently, only The Fly™ can discriminate between different patient populations (post-traumatic and non-traumatic neck pain). The sensitivity, specificity and responsiveness of the methods have to be assessed in future research. The dynamic method The Fly™ appears to be more reliable than the HRA-to-NHP and is able to discriminate between different patient populations. The diagnostic potential is to be confirmed in future research. Copyright © 2012 Elsevier B.V. All rights reserved.
Troester, Jordan C.; Jasmin, Jason G.; Duffield, Rob
2018-01-01
The present study examined the inter-trial (within test) and inter-test (between test) reliability of single-leg balance and single-leg landing measures performed on a force plate in professional rugby union players using commercially available software (SpartaMARS, Menlo Park, USA). Twenty-four players undertook test – re-test measures on two occasions (7 days apart) on the first training day of two respective pre-season weeks following 48h rest and similar weekly training loads. Two 20s single-leg balance trials were performed on a force plate with eyes closed. Three single-leg landing trials were performed by jumping off two feet and landing on one foot in the middle of a force plate 1m from the starting position. Single-leg balance results demonstrated acceptable inter-trial reliability (ICC = 0.60-0.81, CV = 11-13%) for sway velocity, anterior-posterior sway velocity, and mediolateral sway velocity variables. Acceptable inter-test reliability (ICC = 0.61-0.89, CV = 7-13%) was evident for all variables except mediolateral sway velocity on the dominant leg (ICC = 0.41, CV = 15%). Single-leg landing results only demonstrated acceptable inter-trial reliability for force based measures of relative peak landing force and impulse (ICC = 0.54-0.72, CV = 9-15%). Inter-test results indicate improved reliability through the averaging of three trials with force based measures again demonstrating acceptable reliability (ICC = 0.58-0.71, CV = 7-14%). Of the variables investigated here, total sway velocity and relative landing impulse are the most reliable measures of single-leg balance and landing performance, respectively. These measures should be considered for monitoring potential changes in postural control in professional rugby union. Key points Single-leg balance demonstrated acceptable inter-trial and inter-test reliability. Single-leg landing demonstrated good inter-trial and inter-test reliability for measures of relative peak landing force and relative impulse, but not time to stabilization. Of the variables investigated, sway velocity and relative landing impulse are the most reliable measures of single-leg balance and landing respectively, and should considered for monitoring changes in postural control. PMID:29769817
Lin, Yen-Sheng; Boninger, Michael L; Day, Kevin A; Koontz, Alicia M
2015-11-01
To investigate the reliability of ultrasonographic measurement of acromiohumeral distance (AHD) and the effects of shoulder positioning on AHD among manual wheelchair users (MWUs) with spinal cord injury (SCI) and an able-bodied control group. Ten MWUs with SCI and 10 able-bodied subjects participated in this study. The ultrasonographic measurements of AHD from each subject were obtained by two raters during passive and active scapular plane arm elevation in neutral, 45°, 90° with and without resistance and in a weight relief raise position. The measurements were recorded again by each rater using the same procedures after a 30-minute time interval. All raters were blinded to each other's measurements. University Laboratories and Veteran Affairs Healthcare System. Intra-rater (intraclass correlation coefficient, ICC > 0.83) and inter-rater (ICC > 0.78) reliability was excellent for both the MWUs with SCI and able-bodied groups across all arm positions except for the 45° position in the control group for one of the raters (intra-rater: ICC < 0.40 and inter-rater: ICC < 0.60). AHD significantly reduced when the shoulder was in the 90° arm elevated positions with or without resistance. Findings from our study demonstrated that ultrasonography is a reliable means to evaluate AHD in both able bodied and individuals with SCI, who are known to have significant shoulder pathology. This technique could be used to develop reference measures and to identify changes in AHD caused by interventions.
Kosse, Nienke M; Caljouw, Simone; Vervoort, Danique; Vuillerme, Nicolas; Lamoth, Claudine J C
2015-08-01
Accelerometer-based assessments can identify elderly with an increased fall risk and monitor interventions. Smart devices, like the iPod Touch, with built-in accelerometers are promising for clinical gait and posture assessments due to easy use and cost-effectiveness. The aim of the present study was to establish the validity and reliability of the iPod Touch for gait and posture assessment. Sixty healthy participants (aged 18-75 years) were measured with an iPod Touch and stand-alone accelerometer while they walked under single- and dual-task conditions, and while standing in parallel and semi-tandem stance with eyes open, eyes closed and when performing a dual task. Cross-correlation values (CCV) showed high correspondence of anterior-posterior and medio-lateral signal patterns (CCV's ≥ 0.88). Validity of gait parameters (foot contacts, index of harmonicity, and amplitude variability) and standing posture parameters [root mean square of accelerations, median power frequency (MPF) and sway area] as indicated by intra-class correlation (ICC) was high (ICC = 0.85-0.99) and test-retest reliability was good (ICC = 0.81-0.97), except for MPF (ICC = 0.59-0.87). Overall, the iPod Touch obtained valid and reliable measures of gait and postural control in healthy adults of all ages under different conditions. Additionally, smart devices have the potential to be used for clinical gait and posture assessments.
Color calibration and color-managed medical displays: does the calibration method matter?
NASA Astrophysics Data System (ADS)
Roehrig, Hans; Rehm, Kelly; Silverstein, Louis D.; Dallas, William J.; Fan, Jiahua; Krupinski, Elizabeth A.
2010-02-01
Our laboratory has investigated the efficacy of a suite of color calibration and monitor profiling packages which employ a variety of color measurement sensors. Each of the methods computes gamma correction tables for the red, green and blue color channels of a monitor that attempt to: a) match a desired luminance range and tone reproduction curve; and b) maintain a target neutral point across the range of grey values. All of the methods examined here produce International Color Consortium (ICC) profiles that describe the color rendering capabilities of the monitor after calibration. Color profiles incorporate a transfer matrix that establishes the relationship between RGB driving levels and the International Commission on Illumination (CIE) XYZ (tristimulus) values of the resulting on-screen color; the matrix is developed by displaying color patches of known RGB values on the monitor and measuring the tristimulus values with a sensor. The number and chromatic distribution of color patches varies across methods and is usually not under user control. In this work we examine the effect of employing differing calibration and profiling methods on rendition of color images. A series of color patches encoded in sRGB color space were presented on the monitor using color-management software that utilized the ICC profile produced by each method. The patches were displayed on the calibrated monitor and measured with a Minolta CS200 colorimeter. Differences in intended and achieved luminance and chromaticity were computed using the CIE DE2000 color-difference metric, in which a value of ▵E = 1 is generally considered to be approximately one just noticeable difference (JND) in color. We observed between one and 17 JND's for individual colors, depending on calibration method and target.
NASA Astrophysics Data System (ADS)
Dinkins, Matthew; Colley, Stephen
2008-07-01
Hardware and software specialized for real time control reduce the timing jitter of executables when compared to off-the-shelf hardware and software. However, these specialized environments are costly in both money and development time. While conventional systems have a cost advantage, the jitter in these systems is much larger and potentially problematic. This study analyzes the timing characterstics of a standard Dell server running a fully featured Linux operating system to determine if such a system would be capable of meeting the timing requirements for closed loop operations. Investigations are preformed on the effectiveness of tools designed to make off-the-shelf system performance closer to specialized real time systems. The Gnu Compiler Collection (gcc) is compared to the Intel C Compiler (icc), compiler optimizations are investigated, and real-time extensions to Linux are evaluated.
Calbindins decreased after space flight
NASA Technical Reports Server (NTRS)
Sergeev, I. N.; Rhoten, W. B.; Carney, M. D.
1996-01-01
Exposure of the body to microgravity during space flight causes a series of well-documented changes in Ca2+ metabolism, yet the cellular and molecular mechanisms leading to these changes are poorly understood. Calbindins, vitamin D-dependent Ca2+ binding proteins, are believed to have a significant role in maintaining cellular Ca2+ homeostasis. In this study, we used biochemical and immunocytochemical approaches to analyze the expression of calbindin-D28k and calbindin-D9k in kidneys, small intestine, and pancreas of rats flown for 9 d aboard the space shuttle. The effects of microgravity on calbindins in rats from space were compared with synchronous Animal Enclosure Module controls, modeled weightlessness animals (tail suspension), and their controls. Exposure to microgravity resulted in a significant and sustained decrease in calbindin-D28k content in the kidney and calbindin-D9k in the small intestine of flight animals, as measured by enzyme-linked immunosorbent assay (ELISA). Modeled weightlessness animals exhibited a similar decrease in calbindins by ELISA. Immunocytochemistry (ICC) in combination with quantitative computer image analysis was used to measure in situ the expression of calbindins in the kidney and the small intestine, and the expression of insulin in pancreas. There was a large decrease of immunoreactivity in renal distal tubular cell-associated calbindin-D28k and in intestinal absorptive cell-associated calbindin-D9k of space flight and modeled weightlessness animals compared with matched controls. No consistent difference in pancreatic insulin immunoreactivity between space flight, modeled weightlessness, and controls was observed. Regression analysis of results obtained by quantitative ICC and ELISA for space flight, modeled weightlessness animals, and their controls demonstrated a significant correlation. These findings after a short-term exposure to microgravity or modeled weightlessness suggest that a decreased expression of calbindins may contribute to the disorders of Ca2+ metabolism induced by space flight.
Trait-Like Vulnerability to Total and Partial Sleep Loss
Rupp, Tracy L.; Wesensten, Nancy J.; Balkin, Thomas J.
2012-01-01
Objective: To determine the extent to which individual differences in vulnerability to total sleep deprivation also reflect individual differences in vulnerability to multiple nights of sleep restriction. Design: Two sleep loss conditions (order counterbalanced) separated by 2 to 4 weeks: (a) total sleep deprivation (TSD) of 2 nights (63 h continuous wakefulness); (b) sleep restriction (SR) of 7 nights of 3 h nightly time in bed (TIB). Both conditions were preceded by 7 in-laboratory nights with 10 h nightly TIB; and followed by 3 recovery nights with 8 h nightly TIB. Measures of cognitive performance (psychomotor vigilance, working memory [1-Back], and mathematical processing), objective alertness, subjective sleepiness, and mood were obtained at regular intervals under both conditions. Intra-class correlation coefficients (ICC) were computed using outcome metrics averaged over the last day (08:00-20:00) of TSD and SR. Setting: Residential sleep/performance testing facility. Participants: Nineteen healthy adults (ages 18-39; 11 males, 8 females). Interventions: 2 nights of TSD and 7 nights SR (3 h nightly TIB). Results: Volunteers who displayed greater vulnerability to TSD displayed greater vulnerability to SR on cognitive performance tasks (ICC: PVT lapses = 0.89; PVT speed = 0.86; 1-Back = 0.88; mathematical processing = 0.68, Ps < 0.05). In addition, trait-like responsivity to TSD/SR was found for mood variables vigor (ICC = 0.91), fatigue (ICC = 0.73), and happiness (ICC = 0.85) (all Ps < 0.05). Conclusion: Resilience to sleep loss is a trait-like characteristic that reflects an individual's ability to maintain performance during both types of sleep loss (SR and TSD). Whether the findings extend to sleep schedules other than those investigated here (63 h of TSD and 7 nights of 3 h nightly TIB) will be the focus of future studies. Citation: Rupp TL; Wesensten NJ; Balkin TJ. Trait-like vulnerability to total and partial sleep loss. SLEEP 2012;35(8):1163-1172. PMID:22851812
Adduru, Viraj R; Michael, Andrew M; Helguera, Maria; Baum, Stefi A; Moore, Gregory J
2017-09-01
Purpose To validate the use of thick-section clinically acquired magnetic resonance (MR) imaging data for estimating total brain volume (TBV), gray matter (GM) volume (GMV), and white matter (WM) volume (WMV) by using three widely used automated toolboxes: SPM ( www.fil.ion.ucl.ac.uk/spm/ ), FreeSurfer ( surfer.nmr.mgh.harvard.edu ), and FSL (FMRIB software library; Oxford Centre for Functional MR Imaging of the Brain, Oxford, England, https://fsl.fmrib.ox.ac.uk/fsl ). Materials and Methods MR images from a clinical archive were used and data were deidentified. The three methods were applied to estimate brain volumes from thin-section research-quality brain MR images and routine thick-section clinical MR images acquired from the same 38 patients (age range, 1-71 years; mean age, 22 years; 11 women). By using these automated methods, TBV, GMV, and WMV were estimated. Thin- versus thick-section volume comparisons were made for each method by using intraclass correlation coefficients (ICCs). Results SPM exhibited excellent ICCs (0.97, 0.85, and 0.83 for TBV, GMV, and WMV, respectively). FSL exhibited ICCs of 0.69, 0.51, and 0.60 for TBV, GMV, and WMV, respectively, but they were lower than with SPM. FreeSurfer exhibited excellent ICC of 0.63 only for TBV. Application of SPM's voxel-based morphometry on the modulated images of thin-section images and interpolated thick-section images showed fair to excellent ICCs (0.37-0.98) for the majority of brain regions (88.47% [306924 of 346916 voxels] of WM and 80.35% [377 282 of 469 502 voxels] of GM). Conclusion Thick-section clinical-quality MR images can be reliably used for computing quantitative brain metrics such as TBV, GMV, and WMV by using SPM. © RSNA, 2017 Online supplemental material is available for this article.
Zuckerman, Scott L; Lakomkin, Nikita; Magarik, Jordan A; Vargas, Jan; Stephens, Marcus; Akinpelu, Babatunde; Spiotta, Alejandro M; Ahmed, Azam; Arthur, Adam S; Fiorella, David; Hanel, Ricardo; Hirsch, Joshua A; Hui, Ferdinand K; James, Robert F; Kallmes, David F; Meyers, Philip M; Niemann, David B; Rasmussen, Peter; Turner, Raymond D; Welch, Babu G; Mocco, J
2018-05-01
The angiographic evaluation of previously coiled aneurysms can be difficult yet remains critical for determining re-treatment. The main objective of this study was to determine the inter-rater reliability for both the Raymond Scale and per cent embolization among a group of neurointerventionalists evaluating previously embolized aneurysms. A panel of 15 neurointerventionalists examined 92 distinct cases of immediate post-coil embolization and 1 year post-embolization angiographs. Each case was presented four times throughout the study, along with alterations in demographics in order to evaluate intra-rater reliability. All respondents were asked to provide the per cent embolization (0-100%) and Raymond Scale grade (1-3) for each aneurysm. Inter-rater reliability was evaluated by computing weighted kappa values (for the Raymond Scale) and intraclass correlation coefficients (ICC) for per cent embolization. 10 neurosurgeons and 5 interventional neuroradiologists evaluated 368 simulated cases. The agreement among all readers employing the Raymond Scale was fair (κ=0.35) while concordance in per cent embolization was good (ICC=0.64). Clinicians with fewer than 10 years of experience demonstrated a significantly greater level of agreement than the group with greater than 10 years (κ=0.39 and ICC=0.70 vs κ=0.28 and ICC=0.58). When the same aneurysm was presented multiple times, clinicians demonstrated excellent consistency when assessing per cent embolization (ICC=0.82), but moderate agreement when employing the Raymond classification (κ=0.58). Identifying the per cent embolization in previously coiled aneurysms resulted in good inter- and intra-rater agreement, regardless of years of experience. The strong agreement among providers employing per cent embolization may make it a valuable tool for embolization assessment in this patient population. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Rudolph, Heike; Ostertag, Silke; Ostertag, Michael; Walter, Michael H; Luthardt, Ralph Gunnar; Kuhn, Katharina
2018-02-01
The aim of this in vitro study was to assess the reliability of two measurement systems for evaluating the marginal and internal fit of dental copings. Sixteen CAD/CAM titanium copings were produced for a prepared maxillary canine. To modify the CAD surface model using different parameters (data density; enlargement in different directions), varying fit was created. Five light-body silicone replicas representing the gap between the canine and the coping were made for each coping and for each measurement method: (1) light microscopy measurements (LMMs); and (2) computer-assisted measurements (CASMs) using an optical digitizing system. Two investigators independently measured the marginal and internal fit using both methods. The inter-rater reliability [intraclass correlation coefficient (ICC)] and agreement [Bland-Altman (bias) analyses]: mean of the differences (bias) between two measurements [the closer to zero the mean (bias) is, the higher the agreement between the two measurements] were calculated for several measurement points (marginal-distal, marginal-buccal, axial-buccal, incisal). For the LMM technique, one investigator repeated the measurements to determine repeatability (intra-rater reliability and agreement). For inter-rater reliability, the ICC was 0.848-0.998 for LMMs and 0.945-0.999 for CASMs, depending on the measurement point. Bland-Altman bias was -15.7 to 3.5 μm for LMMs and -3.0 to 1.9 μm for CASMs. For LMMs, the marginal-distal and marginal-buccal measurement points showed the lowest ICC (0.848/0.978) and the highest bias (-15.7 μm/-7.6 μm). With the intra-rater reliability and agreement (repeatability) for LMMs, the ICC was 0.970-0.998 and bias was -1.3 to 2.3 μm. LMMs showed lower interrater reliability and agreement at the marginal measurement points than CASMs, which indicates a more subjective influence with LMMs at these measurement points. The values, however, were still clinically acceptable. LMMs showed very high intra-rater reliability and agreement for all measurement points, indicating high repeatability.
Rudolph, Heike; Ostertag, Silke; Ostertag, Michael; Walter, Michael H.; LUTHARDT, Ralph Gunnar; Kuhn, Katharina
2018-01-01
Abstract The aim of this in vitro study was to assess the reliability of two measurement systems for evaluating the marginal and internal fit of dental copings. Material and Methods Sixteen CAD/CAM titanium copings were produced for a prepared maxillary canine. To modify the CAD surface model using different parameters (data density; enlargement in different directions), varying fit was created. Five light-body silicone replicas representing the gap between the canine and the coping were made for each coping and for each measurement method: (1) light microscopy measurements (LMMs); and (2) computer-assisted measurements (CASMs) using an optical digitizing system. Two investigators independently measured the marginal and internal fit using both methods. The inter-rater reliability [intraclass correlation coefficient (ICC)] and agreement [Bland-Altman (bias) analyses]: mean of the differences (bias) between two measurements [the closer to zero the mean (bias) is, the higher the agreement between the two measurements] were calculated for several measurement points (marginal-distal, marginal-buccal, axial-buccal, incisal). For the LMM technique, one investigator repeated the measurements to determine repeatability (intra-rater reliability and agreement). Results For inter-rater reliability, the ICC was 0.848-0.998 for LMMs and 0.945-0.999 for CASMs, depending on the measurement point. Bland-Altman bias was −15.7 to 3.5 μm for LMMs and −3.0 to 1.9 μm for CASMs. For LMMs, the marginal-distal and marginal-buccal measurement points showed the lowest ICC (0.848/0.978) and the highest bias (-15.7 μm/-7.6 μm). With the intra-rater reliability and agreement (repeatability) for LMMs, the ICC was 0.970-0.998 and bias was −1.3 to 2.3 μm. Conclusion LMMs showed lower interrater reliability and agreement at the marginal measurement points than CASMs, which indicates a more subjective influence with LMMs at these measurement points. The values, however, were still clinically acceptable. LMMs showed very high intra-rater reliability and agreement for all measurement points, indicating high repeatability. PMID:29412364
Wu, Weifei; Liang, Jie; Du, Yuanli; Tan, Xiaoyi; Xiang, Xuanping; Wang, Wanhong; Ru, Neng; Le, Jinbo
2014-02-06
Although many studies on reliability and reproducibility of measurement have been performed on coronal Cobb angle, few results about reliability and reproducibility are reported on sagittal alignment measurement including the pelvis. We usually use SurgimapSpine software to measure the Cobb angle in our studies; however, there are no reports till date on its reliability and reproducible measurements. Sixty-eight standard standing posteroanterior whole-spine radiographs were reviewed. Three examiners carried out the measurements independently under the settings of manual measurement on X-ray radiographies and SurgimapSpine software on the computer. Parameters measured included pelvic incidence, sacral slope, pelvic tilt, Lumbar lordosis (LL), thoracic kyphosis, and coronal Cobb angle. SPSS 16.0 software was used for statistical analyses. The means, standard deviations, intraclass and interclass correlation coefficient (ICC), and 95% confidence intervals (CI) were calculated. There was no notable difference between the two tools (P = 0.21) for the coronal Cobb angle. In the sagittal plane parameters, the ICC of intraobserver reliability for the manual measures varied from 0.65 (T2-T5 angle) to 0.95 (LL angle). Further, for SurgimapSpine tool, the ICC ranged from 0.75 to 0.98. No significant difference in intraobserver reliability was found between the two measurements (P > 0.05). As for the interobserver reliability, measurements with SurgimapSpine tool had better ICC (0.71 to 0.98 vs 0.59 to 0.96) and Pearson's coefficient (0.76 to 0.99 vs 0.60 to 0.97). The reliability of SurgimapSpine measures was significantly higher in all parameters except for the coronal Cobb angle where the difference was not significant (P > 0.05). Although the differences between the two methods are very small, the results of this study indicate that the SurgimapSpine measurement is an equivalent measuring tool to the traditional manual in coronal Cobb angle, but is advantageous in spino-pelvic measurement in T2-T5, PT, PI, SS, and LL.
2014-01-01
Background Although many studies on reliability and reproducibility of measurement have been performed on coronal Cobb angle, few results about reliability and reproducibility are reported on sagittal alignment measurement including the pelvis. We usually use SurgimapSpine software to measure the Cobb angle in our studies; however, there are no reports till date on its reliability and reproducible measurements. Methods Sixty-eight standard standing posteroanterior whole-spine radiographs were reviewed. Three examiners carried out the measurements independently under the settings of manual measurement on X-ray radiographies and SurgimapSpine software on the computer. Parameters measured included pelvic incidence, sacral slope, pelvic tilt, Lumbar lordosis (LL), thoracic kyphosis, and coronal Cobb angle. SPSS 16.0 software was used for statistical analyses. The means, standard deviations, intraclass and interclass correlation coefficient (ICC), and 95% confidence intervals (CI) were calculated. Results There was no notable difference between the two tools (P = 0.21) for the coronal Cobb angle. In the sagittal plane parameters, the ICC of intraobserver reliability for the manual measures varied from 0.65 (T2–T5 angle) to 0.95 (LL angle). Further, for SurgimapSpine tool, the ICC ranged from 0.75 to 0.98. No significant difference in intraobserver reliability was found between the two measurements (P > 0.05). As for the interobserver reliability, measurements with SurgimapSpine tool had better ICC (0.71 to 0.98 vs 0.59 to 0.96) and Pearson’s coefficient (0.76 to 0.99 vs 0.60 to 0.97). The reliability of SurgimapSpine measures was significantly higher in all parameters except for the coronal Cobb angle where the difference was not significant (P > 0.05). Conclusion Although the differences between the two methods are very small, the results of this study indicate that the SurgimapSpine measurement is an equivalent measuring tool to the traditional manual in coronal Cobb angle, but is advantageous in spino-pelvic measurement in T2-T5, PT, PI, SS, and LL. PMID:24502397
Dave, Maneesh; Hayashi, Yujiro; Gajdos, Gabriella B; Smyrk, Thomas C; Svingen, Phyllis A; Kvasha, Sergiy M; Lorincz, Andrea; Dong, Haidong; Faubion, William A; Ordog, Tamas
2015-05-01
After allogeneic transplantation, murine stem cells (SCs) for interstitial cells of Cajal (ICCs), electrical pacemaker, and neuromodulator cells of the gut, were incorporated into gastric ICC networks, indicating in vivo immunosuppression. Immunosuppression is characteristic of bone marrow- and other non-gut-derived mesenchymal stem cells (MSCs), which are emerging as potential therapeutic agents against autoimmune diseases, including inflammatory bowel disease. Therefore, we investigated whether gut-derived ICC-SCs could also mitigate experimental colitis and studied the mechanisms of ICC-SC-mediated immunosuppression in relation to MSC-induced pathways. Isolated ICC-SCs were studied by transcriptome profiling, cytokine assays, flow cytometry, mixed lymphocyte reaction, and T-cell proliferation assay. Mice with acute and chronic colitis induced by dextran sulfate sodium and T-cell transfer, respectively, were administered ICC-SCs intraperitoneally and evaluated for disease activity by clinical and pathological assessment and for ICC-SC homing by live imaging. Unlike strain-matched dermal fibroblasts, intraperitoneally administered ICC-SCs preferentially homed to the colon and reduced the severity of both acute and chronic colitis assessed by clinical and blind pathological scoring. ICC-SCs profoundly suppressed T-cell proliferation in vitro. Similar to MSCs, ICC-SCs strongly expressed cyclooxygenase 1/2 and basally secreted prostaglandin E2. Indomethacin, a cyclooxygenase inhibitor, countered the ICC-SC-mediated suppression of T-cell proliferation. In contrast, we found no role for regulatory T-cell-, programmed death receptor-, and transforming growth factor-β-mediated mechanisms reported in MSCs; and transcriptome profiling did not support a relationship between ICC-SCs and MSCs. Murine ICC-SCs belong to a class different from MSCs and potently mitigate experimental colitis via prostaglandin E2-mediated immunosuppression. Copyright © 2015 AGA Institute. Published by Elsevier Inc. All rights reserved.
Evidence of negative leaders which precede fast rise ICC pulses of upward
NASA Astrophysics Data System (ADS)
Yoshida, S.; Akita, M.; Morimoto, T.; Ushio, T.; Kawasaki, Z.; Wang, D.; Takagi, N.
2008-12-01
During winter thunderstorm season in Japan, a lightning observation campaign was conducted with using a VHF broadband digital interferometer (DITF), a capacitive antenna, and Rogowski coils to study the charge transfer mechanism associated with ICC pulses of upward lightning. All the detection systems recorded one upward negative lightning stroke hitting a lightning protection tower. The upward lightning consists of only the Initial Stage (IS) with one upward positive leader and six ICC pulses. The six ICC pulses are sub-classified clearly into two types according to current pulse shapes. The type 1 ICC pulses have a higher geometric mean (GM) current peak of 17 kA and a shorter GM 10-90% risetime of 8.9 μs, while the type 2 ICC pulses have a lower GM current peak of 0.34 kA and longer GM 10-90% risetime of 55 μs. The type 1 ICC pulses have the preceding negative leaders connecting to the channel of the continuing current, while the type 2 ICC pulses have no clear preceding negative leader. These negative leaders prior to the type 1 ICC pulses probably caused the current increases of the ICC pulses, which means that the negative leaders created the channels for the ICC pulses. The height of the space charge transferred by one of the type 1 ICC pulses was estimated about 700 m above sea level at most. This observation result is the first evidence to show explicitly the existence of the negative leaders prior to the fast rise ICC pulse. Furthermore, the result shows that space charge could exist at a low attitude such as 700 m above sea level. This fact is one of the reasons why upward lightning occurs even from rather low structures during winter thunderstorm season in Japan.
Eeles, Abbey L; Olsen, Joy E; Walsh, Jennifer M; McInnes, Emma K; Molesworth, Charlotte M L; Cheong, Jeanie L Y; Doyle, Lex W; Spittle, Alicia J
2017-02-01
Neurobehavioral assessments provide insight into the functional integrity of the developing brain and help guide early intervention for preterm (<37 weeks' gestation) infants. In the context of shorter hospital stays, clinicians often need to assess preterm infants prior to term equivalent age. Few neurobehavioral assessments used in the preterm period have established interrater reliability. To evaluate the interrater reliability of the Hammersmith Neonatal Neurological Examination (HNNE) and the NICU Network Neurobehavioral Scale (NNNS), when used both preterm and at term (>36 weeks). Thirty-five preterm infants and 11 term controls were recruited. Five assessors double-scored the HNNE and NNNS administered either preterm or at term. A one-way random effects, absolute, single-measures interclass correlation coefficient (ICC) was calculated to determine interrater reliability. Interrater reliability for the HNNE was excellent (ICC > 0.74) for optimality scores, and good (ICC 0.60-0.74) to excellent for subtotal scores, except for 'Tone Patterns' (ICC 0.54). On the NNNS, interrater reliability was predominantly excellent for all items. Interrater agreement was generally excellent at both time points. Overall, the HNNE and NNNS neurobehavioral assessments demonstrated mostly excellent interrater reliability when used prior to term and at term.
Civil commitment law, mental health services, and US homicide rates.
Segal, Steven P
2012-09-01
The study considers whether involuntary civil comment (ICC) statute provisions are associated with homicide rates. Do statutes based solely upon dangerousness criteria versus broader ICC-criteria-i.e. "need for treatment," "protection of health and safety," and family protection-have differential associations related to their goal of reducing the frequency of homicide? State-level data were obtained from online data bases and key-informant surveys. Ordinary-least-squares and Poisson regression were used to evaluate the association between statute characteristics, mental health system characteristics, and 2004 Homicide Rates after controlling for firearm-control-law restrictiveness and social-economic-demographic-geographic-and-political indicators historically related to homicide rate variation. Poisson and OLS models, respectively, were significant: likelihood ratio χ(2) = 108.47, df = 10; p < 0.000 and Adj. R (2) = 0.72; df = 10, 25; F = 10.21; p < 0.000. Poisson results indicate that social-economic-demographic-geographic-and-political-indicators had the strongest association with state homicide rates (p < 0.000). Lower rates were associated with: broader ICC-criteria (p ≤ 0.01), fewer inpatient-bed access problems (p ≤ 0.03), and better mental health system ratings (p ≤ 0.04). OLS results indicate that social-economic-demographic-geographic-and-political indicators accounted for 25% of homicide rate variation. Broader ICC-criteria were associated with 1.42 less homicides per 100,000. Less access to psychiatric inpatient-beds and more poorly rated mental health systems were associated with increases in the homicide rates of 1.08 and 0.26 per 100,000, respectively. While social-economic-demographic-geographic-and-political indicators show the strongest association with homicide rate variation, the results show the importance and potentially preventive utility of broader ICC criteria, increased psychiatric inpatient-bed access, and better performing mental health systems as factors contributing to homicide rate variation.
Jones-Jordan, Lisa A.; Sinnott, Loraine T.; Graham, Nicholas D.; Cotter, Susan A.; Kleinstein, Robert N.; Manny, Ruth E.; Mutti, Donald O.; Twelker, J. Daniel; Zadnik, Karla
2014-01-01
Purpose. We determined the correlation between sibling refractive errors adjusted for shared and unique environmental factors using data from the Collaborative Longitudinal Evaluation of Ethnicity and Refractive Error (CLEERE) Study. Methods. Refractive error from subjects' last study visits was used to estimate the intraclass correlation coefficient (ICC) between siblings. The correlation models used environmental factors (diopter-hours and outdoor/sports activity) assessed annually from parents by survey to adjust for shared and unique environmental exposures when estimating the heritability of refractive error (2*ICC). Results. Data from 700 families contributed to the between-sibling correlation for spherical equivalent refractive error. The mean age of the children at the last visit was 13.3 ± 0.90 years. Siblings engaged in similar amounts of near and outdoor activities (correlations ranged from 0.40–0.76). The ICC for spherical equivalent, controlling for age, sex, ethnicity, and site was 0.367 (95% confidence interval [CI] = 0.304, 0.420), with an estimated heritability of no more than 0.733. After controlling for these variables, and near and outdoor/sports activities, the resulting ICC was 0.364 (95% CI = 0.304, 0.420; estimated heritability no more than 0.728, 95% CI = 0.608, 0.850). The ICCs did not differ significantly between male–female and single sex pairs. Conclusions. Adjusting for shared family and unique, child-specific environmental factors only reduced the estimate of refractive error correlation between siblings by 0.5%. Consistent with a lack of association between myopia progression and either near work or outdoor/sports activity, substantial common environmental exposures had little effect on this correlation. Genetic effects appear to have the major role in determining the similarity of refractive error between siblings. PMID:25205866
Intelligent cruise control field operational test : interim report
DOT National Transportation Integrated Search
1997-03-01
This interim document reports on a cooperative agreement between NHTSA and UMTRI entitled Intelligent Cruise Control (ICC) Field Operational Test (FOT). The overarching goal of the work is to characterize safety and comfort issues that are fundamenta...
Lee, Kyoung Min; Lee, Jaebong; Chung, Chin Youb; Ahn, Soyeon; Sung, Ki Hyuk; Kim, Tae Won; Lee, Hui Jong; Park, Moon Seok
2012-06-01
Intra-class correlation coefficients (ICCs) provide a statistical means of testing the reliability. However, their interpretation is not well documented in the orthopedic field. The purpose of this study was to investigate the use of ICCs in the orthopedic literature and to demonstrate pitfalls regarding their use. First, orthopedic articles that used ICCs were retrieved from the Pubmed database, and journal demography, ICC models and concurrent statistics used were evaluated. Second, reliability test was performed on three common physical examinations in cerebral palsy, namely, the Thomas test, the Staheli test, and popliteal angle measurement. Thirty patients were assessed by three orthopedic surgeons to explore the statistical methods testing reliability. Third, the factors affecting the ICC values were examined by simulating the data sets based on the physical examination data where the ranges, slopes, and interobserver variability were modified. Of the 92 orthopedic articles identified, 58 articles (63%) did not clarify the ICC model used, and only 5 articles (5%) described all models, types, and measures. In reliability testing, although the popliteal angle showed a larger mean absolute difference than the Thomas test and the Staheli test, the ICC of popliteal angle was higher, which was believed to be contrary to the context of measurement. In addition, the ICC values were affected by the model, type, and measures used. In simulated data sets, the ICC showed higher values when the range of data sets were larger, the slopes of the data sets were parallel, and the interobserver variability was smaller. Care should be taken when interpreting the absolute ICC values, i.e., a higher ICC does not necessarily mean less variability because the ICC values can also be affected by various factors. The authors recommend that researchers clarify ICC models used and ICC values are interpreted in the context of measurement.
Regan, Timothy; Paul, Christine; Ishiguchi, Paul; D'Este, Catherine; Koller, Claudia; Forshaw, Kristy; Noble, Natasha; Oldmeadow, Christopher; Bisquera, Alessandra; Eades, Sandra
2017-10-17
The objective of this study was to determine the concordance between data extracted from two Clinical Decision Support Systems regarding diabetes testing and monitoring at Aboriginal Community Controlled Health Services in Australia. De-identified PenCAT and Communicare Systems data were extracted from the services allocated to the intervention arm of a diabetes care trial, and intra-class correlations for each extracted item were derived at a service level. Strong to very strong correlations between the two data sources were found regarding the total number of patients with diabetes per service (Intra-class correlation [ICC] = 0.99), as well as the number (ICC = 0.98-0.99) and proportion (ICC = 0.96) of patients with diabetes by gender. The correlation was moderate for the number and proportion of Type 2 diabetes patients per service in the group aged 18-34 years (ICC = 0.65 and 0.8-0.82 respectively). Strong to very strong correlations were found for numbers and proportions of patients being tested for diabetes, and for appropriate monitoring of patients known to have diabetes (ICC = 0.998-1.00). This indicated a generally high degree of concordance between whole-service data extracted by the two Clinical Decision Support Systems. Therefore, the less expensive or less complex option (depending on the individual circumstances of the service) may be appropriate for monitoring diabetes testing and care. However, the extraction of data about subgroups of patients may not be interchangeable.
Swinburne, Nathaniel C; Biederman, Derek M; Besa, Cecilia; Tabori, Nora E; Fischman, Aaron M; Patel, Rahul S; Nowakowski, Francis Scott; Gunasekaran, Ganesh; Schwartz, Myron E; Lookstein, Robert A; Kim, Edward
2017-06-01
The optimal palliative treatment for unresectable intrahepatic cholangiocarcinoma (ICC) remains controversial. While selective internal radiation therapy (SIRT) using yttrium-90 microspheres is a well-accepted treatment for hepatocellular carcinoma, data related to its use for locally advanced ICC remain relatively scarce. Twenty-nine patients (mean age 66 ± 11 years; 15 female) with unresectable biopsy-proven ICC treated with SIRT between June 2008 and April 2015 were retrospectively evaluated for post-treatment toxicity, overall survival, and imaging response using response evaluation criteria in solid tumors (RECIST) 1.1 criteria. RECIST 1.1 response was evaluable following 26 treatments [complete response (CR):0, partial response (PR):3; stable disease (SD):16, progression of disease (PD):7]. Objective response rate (CR+PR) was 12%. Disease control rate (CR+PR+SD) was 73%. Median time to progression was 5.6 [95% confidence interval (CI): 0-12.0] months. Median survival following SIRT was 9.1 (95% CI: 1.7-16.4) months. Post-treatment survival was prolonged in patients with absence of extrahepatic disease (p = 0.03) and correlated with RECIST 1.1 response (p = 0.02). Toxicities were limited to grade I severity and occurred following 27% of treatments. These findings support the safe, effective use of SIRT for unresectable ICC. Post-treatment survival is prolonged in patients with absence of extrahepatic disease at baseline. RECIST 1.1 response following SIRT for ICC is predictive of survival.
Changes in membrane cholesterol affect caveolin-1 localization and ICC-pacing in mouse jejunum.
Daniel, E E; Bodie, Gregory; Mannarino, Marco; Boddy, Geoffrey; Cho, Woo-Jung
2004-07-01
Pacing of mouse is dependent on the spontaneous activity of interstitial cells of Cajal in the myenteric plexus (ICC-MP). These ICC, as well as intestinal smooth muscle, contain small membrane invaginations called caveolae. Caveolae are signaling centers formed by insertions of caveolin proteins in the inner aspect of the plasma membrane. Caveolins bind signaling proteins and thereby negatively modulate their signaling. We disrupted caveolae by treating intestinal segments with methyl beta-clodextrin (CD) to remove cholesterol or with water-soluble cholesterol (WSC) to load cholesterol. Both of these treatments reduced pacing frequencies, and these effects were reversed by the other agent. These treatments also inhibited paced contractions, but complete reversal was not observed. To evaluate the specificity of the effects of CD and WSC, additional studies were made of their effects on responses to carbamoyl choline and to stimulation of cholinergic nerves. Neither of these treatments affected these sets of responses compared with their respective time controls. Immunochemical and ultrastructural studies showed that caveolin 1 was present in smooth muscle membranes and ICC-MP. CD depleted both caveolin 1 and caveolae, whereas WSC increased the amount of caveolin 1 immunoreactivity and altered its distribution but failed to increase the number of caveolae. The effects of each agent were reversed in major part by the other. We conclude that signaling through caveolae may play a role in pacing by ICC but does not affect responses to acetylcholine from nerves or when added exogenously.
Nutrient estimation from an FFQ developed for a black Zimbabwean population
Merchant, Anwar T; Dehghan, Mahshid; Chifamba, Jephat; Terera, Getrude; Yusuf, Salim
2005-01-01
Background There is little information in the literature on methods of food composition database development to calculate nutrient intake from food frequency questionnaire (FFQ) data. The aim of this study is to describe the development of an FFQ and a food composition table to calculate nutrient intake in a Black Zimbabwean population. Methods Trained interviewers collected 24-hour dietary recalls (24 hr DR) from high and low income families in urban and rural Zimbabwe. Based on these data and input from local experts we developed an FFQ, containing a list of frequently consumed foods, standard portion sizes, and categories of consumption frequency. We created a food composition table of the foods found in the FFQ so that we could compute nutrient intake. We used the USDA nutrient database as the main resource because it is relatively complete, updated, and easily accessible. To choose the food item in the USDA nutrient database that most closely matched the nutrient content of the local food we referred to a local food composition table. Results Almost all the participants ate sadza (maize porridge) at least 5 times a week, and about half had matemba (fish) and caterpillar more than once a month. Nutrient estimates obtained from the FFQ data by using the USDA and Zimbabwean food composition tables were similar for total energy intake intra class correlation (ICC) = 0.99, and carbohydrate (ICC = 0.99), but different for vitamin A (ICC = 0.53), and total folate (ICC = 0.68). Conclusion We have described a standardized process of FFQ and food composition database development for a Black Zimbabwean population. PMID:16351722
Interhemispheric Inhibition Measurement Reliability in Stroke: A Pilot Study
Cassidy, Jessica M.; Chu, Haitao; Chen, Mo; Kimberley, Teresa J.; Carey, James R.
2016-01-01
Objective Reliable transcranial magnetic stimulation (TMS) measures for probing corticomotor excitability are important when assessing the physiological effects of non-invasive brain stimulation. The primary objective of this study was to examine test-retest reliability of an interhemispheric inhibition (IHI) index measurement in stroke. Materials and Methods Ten subjects with chronic stroke (≥ 6 months) completed two IHI testing sessions per week for three weeks (six testing sessions total). A single investigator measured IHI in the contra- to-ipsilesional primary motor cortex direction and in the opposite direction using bilateral paired-pulse TMS. Weekly sessions were separated by 24 hours with a 1-week washout period separating testing weeks. To determine if motor-evoked potential (MEP) quantification method affected measurement reliability, IHI indices computed from both MEP amplitude and area responses were found. Reliability was assessed with two-way, mixed intraclass correlation coefficients (ICC(3,k)). Standard error of measurement and minimal detectable difference statistics were also determined. Results With the exception of the initial testing week, IHI indices measured in the contra-to-ipsilesional hemisphere direction demonstrated moderate to excellent reliability (ICC = 0.725 – 0.913). Ipsi-to-contralesional IHI indices depicted poor or invalid reliability estimates throughout the three-week testing duration (ICC= −1.153 – 0.105). The overlap of ICC 95% confidence intervals suggested that IHI indices using MEP amplitude vs. area measures did not differ with respect to reliability. Conclusions IHI indices demonstrated varying magnitudes of reliability irrespective of MEP quantification method. Several strategies for improving IHI index measurement reliability are discussed. PMID:27333364
Negrete, Lindsey M.; Middleton, Michael S.; Clark, Lisa; Wolfson, Tanya; Gamst, Anthony C.; Lam, Jessica; Changchien, Chris; Deyoung-Dominguez, Ivan M.; Hamilton, Gavin; Loomba, Rohit; Schwimmer, Jeffrey; Sirlin, Claude B.
2013-01-01
Purpose To prospectively describe magnitude-based multi-echo gradient-echo hepatic proton density fat fraction (PDFF) inter-examination precision at 3T. Materials and Methods In this prospective, IRB approved, HIPAA compliant study, written informed consent was obtained from 29 subjects (body mass indexes > 30kg/m2). Three 3T magnetic resonance imaging (MRI) examinations were obtained over 75-90 minutes. Segmental, lobar, and whole liver PDFF were estimated (using three, four, five, or six echoes) by magnitude-based multi-echo MRI in co-localized regions of interest (ROIs). For estimate (using three, four, five, or six echoes), at each anatomic level (segmental, lobar, whole liver), three inter-examination precision metrics were computed: intra-class correlation coefficient (ICC), standard deviation (SD), and range. Results Magnitude-based PDFF estimates using each reconstruction method showed excellent inter-examination precision for each segment (ICC ≥ 0.992; SD ≤ 0.66%; range ≤ 1.24%), lobe (ICC ≥ 0.998; SD ≤ 0.34%; range ≤ 0.64%), and the whole liver (ICC = 0.999; SD ≤ 0.24%; range ≤ 0.45%). Inter-examination precision was unaffected by whether PDFF was estimated using three, four, five, or six echoes. Conclusion Magnitude-based PDFF estimation shows high inter-examination precision at segmental, lobar, and whole liver anatomic levels, supporting its use in clinical care or clinical trials. The results of this study suggest that longitudinal hepatic PDFF change greater than 1.6% is likely to represent signal rather than noise. PMID:24136736
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haidu, Marion, E-mail: marion.haidu@i-med.ac.at; Dobrozemsky, Georg, E-mail: georg.dobroszemsky@i-med.ac.at; Schullian, Peter, E-mail: peter.schullian@i-med.ac.at
Purpose: To evaluate treatment effects, complications, and outcome of percutaneous stereotactic radiofrequency ablation (SRFA) of intrahepatic cholangiocarcinoma (ICC). Patients and Methods: Eleven consecutive patients (nine men and two women) with a total of 36 inoperable ICCs (18 initial lesions, 16 lesions newly detected during follow-up, and two local recurrences) underwent SRFA between December 2004 and June 2010. Two different radiofrequency ablation (RFA) devices with internally cooled electrodes were used. Tumor diameters ranged from 0.5 to 10 cm (median 3.0 cm). A total of 23 SRFA sessions were performed. The efficacy of SRFA was evaluated by contrast-enhanced computed tomography or magneticmore » resonance imaging 1 month after treatment and then every 3 months. Results: Primary technical effectiveness rate was 92%. Further follow-up every 3 months revealed three local recurrences (8%), two of which were successfully retreated, resulting in a secondary technical effectiveness rate of 98%. After a total of 23 RFA sessions, three major complications occurred (13%) that could be managed interventionally. Mean follow-up time was 35 months (range 12-81 months). One- and 3-year overall survival rates were 91 and 71%, respectively. The median overall survival was 60 months (according to the life table method). Eight (73%) of 11 patients were still alive at the end of follow-up. Conclusion: SRFA is effective in the treatment of unresectable ICC even if the tumor is large and located close to major vessels. SRFA shows a survival benefit compared to other palliative treatment options and may also be considered as the first-line local treatment of ICCs in selected patients.« less
Aly, Sharif S; Zhao, Jianyang; Li, Ben; Jiang, Jiming
2014-01-01
The Intraclass Correlation Coefficient (ICC) is commonly used to estimate the similarity between quantitative measures obtained from different sources. Overdispersed data is traditionally transformed so that linear mixed model (LMM) based ICC can be estimated. A common transformation used is the natural logarithm. The reliability of environmental sampling of fecal slurry on freestall pens has been estimated for Mycobacterium avium subsp. paratuberculosis using the natural logarithm transformed culture results. Recently, the negative binomial ICC was defined based on a generalized linear mixed model for negative binomial distributed data. The current study reports on the negative binomial ICC estimate which includes fixed effects using culture results of environmental samples. Simulations using a wide variety of inputs and negative binomial distribution parameters (r; p) showed better performance of the new negative binomial ICC compared to the ICC based on LMM even when negative binomial data was logarithm, and square root transformed. A second comparison that targeted a wider range of ICC values showed that the mean of estimated ICC closely approximated the true ICC.
Maldaner, Nicolai; Stienen, Martin N; Bijlenga, Philippe; Croci, Davide; Zumofen, Daniel W; Dalonzo, Donato; Marbacher, Serge; Maduri, Rodolfo; Daniel, Roy Thomas; Serra, Carlo; Esposito, Giuseppe; Neidert, Marian Christoph; Bozinov, Oliver; Regli, Luca; Burkhardt, Jan-Karl
2017-07-01
To determine interrater agreement in the initial radiologic characterization of ruptured intracranial aneurysms based on computed tomography angiography (CTA) with special emphasis on the rater's level of experience. One junior and one senior rater of 5 high-volume neurovascular tertiary centers evaluated anonymized CTA images of 30 consecutive patients with aneurysmal subarachnoid hemorrhage. Each rater described location, side, size, and morphology in a standardized manner. Interrater variability was analyzed using intraclass correlation and Fleiss' kappa analysis. There was a high level of agreement for location (κ = 0.76, 95% confidence interval [CI] 0.74-0.79), side (κ = 0.95, CI 0.91-0.99), maximum diameter (intraclass correlation coefficient [ICC] 0.81, CI 0.70-0.90), and dome (ICC 0.78, CI 0.66-0.88) of intracranial aneurysms. In contrast, a lower level of agreement was observed for aneurysms' neck diameter (ICC 0.39, CI 0.28-0.58), the presence of multiple aneurysms (κ = 0.35, CI 0.30-0.40), and aneurysm morphology (blister κ = 0.11, CI -0.05 to 0.07; fusiform κ = 0.54, CI 0.48-0.60; multilobular, κ = 0.39 CI 0.33-0.45). The interrater agreement in the senior rater group was greater than in the junior rater group. Interrater agreement confirms the benefit of CTA as initial diagnostic imaging in ruptured intracranial aneurysms but not for aneurysm morphology and presence of multiple aneurysms. A trend towards greater interrater agreement between more experienced raters was noticed. Copyright © 2017 Elsevier Inc. All rights reserved.
Choi, Catherine J; Lefebvre, Daniel R; Yoon, Michael K
2016-06-01
The aim of this article is to validate the accuracy of Facial Assessment by Computer Evaluation (FACE) program in eyelid measurements. Sixteen subjects between the ages of 27 and 65 were included with IRB approval. Clinical measurements of upper eyelid margin reflex distance (MRD1) and inter-palpebral fissure (IPF) were obtained. Photographs were then taken with a digital single lens reflex camera with built-in pop-up flash (dSLR-pop) and a dSLR with lens-mounted ring flash (dSLR-ring) with the cameras upright, rotated 90, 180, and 270 degrees. The images were analyzed using both the FACE and ImageJ software to measure MRD1 and IPF.Thirty-two eyes of sixteen subjects were included. Comparison of clinical measurement of MRD1 and IPF with FACE measurements of photos in upright position showed no statistically significant differences for dSLR-pop (MRD1: p = 0.0912, IPF: p = 0.334) and for dSLR-ring (MRD1: p = 0.105, IPF: p = 0.538). One-to-one comparison of MRD1 and IPF measurements in four positions obtained with FACE versus ImageJ for dSLR-pop showed moderate to substantial agreement for MRD1 (intraclass correlation coefficient = 0.534 upright, 0.731 in 90 degree rotation, 0.627 in 180 degree rotation, 0.477 in 270 degree rotation) and substantial to excellent agreement in IPF (ICC = 0.740, 0.859, 0.849, 0.805). In photos taken with dSLR-ring, there was excellent agreement of all MRD1 (ICC = 0.916, 0.932, 0.845, 0.812) and IPF (ICC = 0.937, 0.938, 0.917, 0.888) values. The FACE program is a valid method for measuring margin reflex distance and inter-palpebral fissure.
Ruiz-España, Silvia; Arana, Estanislao; Moratal, David
2015-07-01
Computer-aided diagnosis (CAD) methods for detecting and classifying lumbar spine disease in Magnetic Resonance imaging (MRI) can assist radiologists to perform their decision-making tasks. In this paper, a CAD software has been developed able to classify and quantify spine disease (disc degeneration, herniation and spinal stenosis) in two-dimensional MRI. A set of 52 lumbar discs from 14 patients was used for training and 243 lumbar discs from 53 patients for testing in conventional two-dimensional MRI of the lumbar spine. To classify disc degeneration according to the gold standard, Pfirrmann classification, a method based on the measurement of disc signal intensity and structure was developed. A gradient Vector Flow algorithm was used to extract disc shape features and for detecting contour abnormalities. Also, a signal intensity method was used for segmenting and detecting spinal stenosis. Novel algorithms have also been developed to quantify the severity of these pathologies. Variability was evaluated by kappa (k) and intra-class correlation (ICC) statistics. Segmentation inaccuracy was below 1%. Almost perfect agreement, as measured by the k and ICC statistics, was obtained for all the analyzed pathologies: disc degeneration (k=0.81 with 95% CI=[0.75..0.88]) with a sensitivity of 95.8% and a specificity of 92.6%, disc herniation (k=0.94 with 95% CI=[0.87..1]) with a sensitivity of 60% and a specificity of 87.1%, categorical stenosis (k=0.94 with 95% CI=[0.90..0.98]) and quantitative stenosis (ICC=0.98 with 95% CI=[0.97..0.98]) with a sensitivity of 70% and a specificity of 81.7%. The proposed methods are reproducible and should be considered as a possible alternative when compared to reference standards. Copyright © 2015 Elsevier Ltd. All rights reserved.
Soler, Zachary M; Pallanch, John F; Sansoni, Eugene Ritter; Jones, Cameron S; Lawrence, Lauren A; Schlosser, Rodney J; Mace, Jess C; Smith, Timothy L
2015-09-01
Commonly used computed tomography (CT) staging systems for chronic rhinosinusitis (CRS) focus on the sinuses and do not quantify disease in the olfactory cleft. The goal of the current study was to determine whether precise measurements of olfactory cleft opacification better correlate with olfaction in patients with CRS. Olfaction was assessed using the 40-item Smell Identification Test (SIT-40) before and after sinus surgery in adult patients. Olfactory cleft opacification was quantified precisely using three-dimensional (3D), computerized volumetric analysis, as well as via semiquantitative Likert scale estimations at predetermined anatomic sites. Sinus opacification was also quantified using the Lund-Mackay staging system. The overall cohort (n = 199) included 89 (44.7%) patients with CRS with nasal polyposis (CRSwNP) and 110 (55.3%) with CRS without nasal polyposis (CRSsNP). The olfactory cleft opacified volume correlated with objective olfaction as determined by the SIT-40 (Spearman's rank correlation coefficient [Rs ] = -0.461; p < 0.001). The correlation was significantly stronger in the CRSwNP subgroup (Rs = -0.573; p < 0.001), whereas no appreciable correlation was found in the CRSsNP group (Rs = -0.141; p = 0.141). Correlations between sinus-specific Lund-Mackay CT scoring and SIT-40 scores were weaker in the CRSwNP (Rs = -0.377; p < 0.001) subgroup but stronger in the CRSsNP (Rs = -0.225; p = 0.018) group when compared to olfactory cleft correlations. Greater intraclass correlations (ICCs) were found between quantitative volumetric measures of olfactory cleft opacification (ICC = 0.844; p < 0.001) as compared with semiquantitative Likert grading (ICC = 0.627; p < 0.001). Quantitative measures of olfactory cleft opacification correlate with objective olfaction, with the strongest correlations seen in patients with nasal polyps. © 2015 ARS-AAOA, LLC.
Jia, Xiaoyang; Chen, Yanxi; Qiang, Minfei; Zhang, Kun; Li, Haobo; Jiang, Yuchen; Zhang, Yijie
2016-07-15
Accurate comprehension of the normal humeral morphology is crucial for anatomical reconstruction in shoulder arthroplasty. However, traditional morphological measurements for humerus were mainly based on cadaver and radiography. The purpose of this study was to provide a series of precise and repeatable parameters of the normal proximal humerus for arthroplasty, based on the three-dimensional (3-D) measurements. Radiographic and 3-D computed tomography (CT) measurements of the proximal humerus were performed in a sample of 120 consecutive adults. Sex differences, two image modalities differences, and correlations of the parameters were evaluated. Intra- and inter-observer reproducibility was evaluated using intraclass correlation coefficients (ICCs). In the male group, all parameters except the neck-shaft angle of humerus, based on 3-D CT images, were greater than those in the female group (P < 0.05). All variables were significantly different between two image modalities (P < 0.05). In 3-D CT measurement, all parameters expect neck-shaft angle had correlation with each other (P < 0.001), particularly between two diameters of the humeral head (r = 0.907). All parameters in the 3-D CT measurement had excellent reproducibility (ICC range, 0.878 to 0.936) that was higher than those in the radiographs (ICC range, 0.741 to 0.858). The present study suggested that 3-D CT was more reproducible than plain radiography in the assessment of morphology of the normal proximal humerus. Therefore, this reproducible modality could be utilized in the preoperative planning. Our data could serve as an effective guideline for humeral component selection and improve the design of shoulder prosthesis.
Mehta, Shraddha; Bastero-Caballero, Rowena F; Sun, Yijun; Zhu, Ray; Murphy, Diane K; Hardas, Bhushan; Koch, Gary
2018-04-29
Many published scale validation studies determine inter-rater reliability using the intra-class correlation coefficient (ICC). However, the use of this statistic must consider its advantages, limitations, and applicability. This paper evaluates how interaction of subject distribution, sample size, and levels of rater disagreement affects ICC and provides an approach for obtaining relevant ICC estimates under suboptimal conditions. Simulation results suggest that for a fixed number of subjects, ICC from the convex distribution is smaller than ICC for the uniform distribution, which in turn is smaller than ICC for the concave distribution. The variance component estimates also show that the dissimilarity of ICC among distributions is attributed to the study design (ie, distribution of subjects) component of subject variability and not the scale quality component of rater error variability. The dependency of ICC on the distribution of subjects makes it difficult to compare results across reliability studies. Hence, it is proposed that reliability studies should be designed using a uniform distribution of subjects because of the standardization it provides for representing objective disagreement. In the absence of uniform distribution, a sampling method is proposed to reduce the non-uniformity. In addition, as expected, high levels of disagreement result in low ICC, and when the type of distribution is fixed, any increase in the number of subjects beyond a moderately large specification such as n = 80 does not have a major impact on ICC. Copyright © 2018 John Wiley & Sons, Ltd.
F.Kaminski, Michal; Bretthauer, Michael; Zauber, Ann G.; Kuipers, Ernst J.; Adami, Hans-Olov; van Ballegooijen, Marjolein; Regula, Jaroslaw; van Leerdam, Monique; Stefansson, Tryggvi; Påhlman, Lars; Dekker, Evelien; Hernán, Miguel A.; Garborg, Kjetil; Hoff, Geir
2017-01-01
Background While colonoscopy screening is widely used in several European countries and the United States, no randomised trials exist to quantify its benefits. The Nordic-European Initiative on Colorectal Cancer (NordICC) is a multinational, randomized controlled trial aiming at investigating the effect of colonoscopy screening on CRC incidence and mortality. This paper describes the rationale and design of the NordICC trial. Material and methods Men and women age 55 to 64 years are drawn from the population registries in the participating countries and randomly assigned to either once-only colonoscopy screening with removal of all detected lesions, or no screening (standard of care in the trial regions). All individuals are followed for 15 years after inclusion using dedicated national registries. Results The primary endpoints of the trial are cumulative CRC-specific death and CRC incidence during 15 years of follow up. We hypothesize a 50% CRC mortality-reducing efficacy of the colonoscopy intervention and predict 50% compliance, yielding a 25% mortality reduction among those invited to screening. For 90% power and a two-sided alpha level of 0.05, using a 2:1 randomisation, 45,600 individuals will be randomised to control, and 22,800 individuals to the colonoscopy group. Interim analyses of the effect of colonoscopy on CRC incidence and mortality will be performed at 10 years follow-up. Conclusions The aim of the NordICC trial is to quantify the effectiveness of population-based colonoscopy screening. This will allow development of evidence-based guidelines for CRC screening in the general population. PMID:22723185
Effect of HIV Infection on Human Papillomavirus Types Causing Invasive Cervical Cancer in Africa
de Vuyst, Hugo; Tenet, Vanessa; Plummer, Martyn; Tully, Stephen; Franceschi, Silvia
2016-01-01
Objectives: HIV infection is known to worsen the outcome of cervical human papillomavirus (HPV) infection and may do so differentially by HPV type. Design: Twenty-one studies were included in a meta-analysis of invasive cervical cancers (ICC) among women infected with HIV in Africa. Method: Type-specific HPV DNA prevalence was compared with data from a similar meta-analysis of HIV-negative ICC using prevalence ratios (PR). Results: HPV detection was similar in 770 HIV-positive (91.2%) and 3846 HIV-negative (89.6%) ICC, but HIV-positive ICC harbored significantly more multiple HPV infections (PR = 1.75, 95% confidence intervals: 1.18 to 2.58), which were significantly more prevalent in ICC tested from cells than from biopsies. HPV16 was the most frequently detected type in HIV-positive ICC (42.5%), followed by HPV18 (22.2%), HPV45 (14.4%), and HPV35 (7.1%). Nevertheless, HIV-positive ICC were significantly less frequently infected with HPV16 than HIV-negative ICC (PR = 0.88, 95% confidence intervals: 0.79 to 0.99). Other high-risk types were significantly more prevalent in HIV-positive ICC, but only for HPV18 was there a significantly higher prevalence of both single and multiple infections in HIV-positive ICC. Increases for other high-risk types were primarily accounted for by multiple infections. The proportion of HPV-positive ICC estimated attributable to HPV16/18 (71.8% in HIV positive, 73.4% in HIV negative) or HPV16/18/31/33/45/52/58 (88.8%, 89.5%) was not affected by HIV. Conclusions: HIV alters the relative carcinogenicity of HPV types, but prophylactic HPV16/18 vaccines may nevertheless prevent a similar proportion of ICC, irrespective of HIV infection. PMID:27331659
NASA Astrophysics Data System (ADS)
Tain, Rong-Wen; Alperin, Noam
2008-03-01
Intracranial compliance (ICC) determines the ability of the intracranial space to accommodate increase in volume (e.g., brain swelling) without a large increase in intracranial pressure (ICP). Therefore, measurement of ICC is potentially important for diagnosis and guiding treatment of related neurological problems. Modeling based approach uses an assumed lumped-parameter model of the craniospinal system (CSS) (e.g., RCL circuit), with either the arterial or the net transcranial blood flow (arterial inflow minus venous outflow) as input and the cranio-spinal cerebrospinal fluid (CSF) flow as output. The phase difference between the output and input is then often used as a measure of ICC However, it is not clear whether there is a predetermined relationship between ICC and the phase difference between these waveforms. A different approach for estimation of ICC has been recently proposed. This approach estimates ICC from the ratio of the intracranial volume and pressure changes that occur naturally with each heartbeat. The current study evaluates the sensitivity of the phase-based and the direct approach to changes in ICC. An RLC circuit model of the cranio-spinal system is used to simulate the cranio-spinal CSF flow for 3 different ICC states using the transcranial blood flows measured by MRI phase contrast from healthy human subjects. The effect of the increase in the ICC on the magnitude and phase response is calculated from the system's transfer function. We observed that within the heart rate frequency range, changes in ICC predominantly affected the amplitude of CSF pulsation and less so the phases. The compliance is then obtained for the different ICC states using the direct approach. The measures of compliance calculated using the direct approach demonstrated the highest sensitivity for changes in ICC. This work explains why phase shift based measure of ICC is less sensitive than amplitude based measures such as the direct approach method.
Vitamin D endocrine system after short-term space flight
NASA Technical Reports Server (NTRS)
Rhoten, William B. (Principal Investigator); Sergeev, Igor N. (Principal Investigator)
1996-01-01
The exposure of the body to microgravity during space flight causes a series of well-documented changes in Ca(2+) metabolism, yet the cellular/molecular mechanisms leading to these changes are poorly understood. There is some evidence for microgravity-induced alterations in the vitamin D endocrine system, which is known to be primarily involved in the regulation of Ca(2+) metabolism. Vitamin D-dependent Ca(2+) binding proteins, or calbindins, are believed to have a significant role in maintaining cellular Ca(2+) homeostasis. We used immunocytochemical, biochemical and molecular approaches to analyze the expression of calbindin-D(sub 28k) and calbindin-D(sub 9k) in kidneys and intestines of rats flown for 9 days aboard the Spacelab 3 mission. The effects of microgravity on calbindins in rats in space vs. 'grounded' animals (synchronous Animal Enclosure Module controls and tail suspension controls) were compared. Exposure to microgravity resulted in a significant decrease in calbindin-D(sub 28k) content in kidneys and calbindin-D(sub 9k) in the intestine of flight and suspended animals, as measured by enzyme-linked immunosorbent assay (ELISA). Immunocytochemistry (ICC) in combination with quantitative computer image analysis was used to measure in situ the expression of calbindins in kidneys and intestine, and insulin in pancreas. There was a large decrease in the distal tubular cell-associated calbindin-D(sub 28k) and absorptive cell-associated calbindin-D(sub 9k) immunoreactivity in the space and suspension kidneys and intestine, as compared with matched ground controls. No consistent differences in pancreatic insulin immunoreactivity between space, suspension and ground controls was observed. There were significant correlations between results by quantitative ICC and ELISA. Western blot analysis showed no consistent changes in the low levels of intestinal and renal vitamin D receptors. These findings suggest that a decreased expression of calbindins after a short-term exposure to microgravity and modelled weightlessness, may affect cellular Ca(2+) homeostasis and contribute to Ca(2+) and bone metabolism disorders induced by space flight.
2014-01-01
An integrated chassis control (ICC) system with active front steering (AFS) and yaw stability control (YSC) is introduced in this paper. The proposed ICC algorithm uses the improved Inverse Nyquist Array (INA) method based on a 2-degree-of-freedom (DOF) planar vehicle reference model to decouple the plant dynamics under different frequency bands, and the change of velocity and cornering stiffness were considered to calculate the analytical solution in the precompensator design so that the INA based algorithm runs well and fast on the nonlinear vehicle system. The stability of the system is guaranteed by dynamic compensator together with a proposed PI feedback controller. After the response analysis of the system on frequency domain and time domain, simulations under step steering maneuver were carried out using a 2-DOF vehicle model and a 14-DOF vehicle model by Matlab/Simulink. The results show that the system is decoupled and the vehicle handling and stability performance are significantly improved by the proposed method. PMID:24782676
Zhu, Bing; Chen, Yizhou; Zhao, Jian
2014-01-01
An integrated chassis control (ICC) system with active front steering (AFS) and yaw stability control (YSC) is introduced in this paper. The proposed ICC algorithm uses the improved Inverse Nyquist Array (INA) method based on a 2-degree-of-freedom (DOF) planar vehicle reference model to decouple the plant dynamics under different frequency bands, and the change of velocity and cornering stiffness were considered to calculate the analytical solution in the precompensator design so that the INA based algorithm runs well and fast on the nonlinear vehicle system. The stability of the system is guaranteed by dynamic compensator together with a proposed PI feedback controller. After the response analysis of the system on frequency domain and time domain, simulations under step steering maneuver were carried out using a 2-DOF vehicle model and a 14-DOF vehicle model by Matlab/Simulink. The results show that the system is decoupled and the vehicle handling and stability performance are significantly improved by the proposed method.
NASA Technical Reports Server (NTRS)
Luck, Rogelio; Ray, Asok
1990-01-01
A procedure for compensating for the effects of distributed network-induced delays in integrated communication and control systems (ICCS) is proposed. The problem of analyzing systems with time-varying and possibly stochastic delays could be circumvented by use of a deterministic observer which is designed to perform under certain restrictive but realistic assumptions. The proposed delay-compensation algorithm is based on a deterministic state estimator and a linear state-variable-feedback control law. The deterministic observer can be replaced by a stochastic observer without any structural modifications of the delay compensation algorithm. However, if a feedforward-feedback control law is chosen instead of the state-variable feedback control law, the observer must be modified as a conventional nondelayed system would be. Under these circumstances, the delay compensation algorithm would be accordingly changed. The separation principle of the classical Luenberger observer holds true for the proposed delay compensator. The algorithm is suitable for ICCS in advanced aircraft, spacecraft, manufacturing automation, and chemical process applications.
Intelligent cruise control field operational test. Volume I, Technical report
DOT National Transportation Integrated Search
1998-05-01
This document reports on a cooperative agreement between NHTSA and UMTRI entitled Intelligent Cruise Control (ICC) Field Operational Test (FOT). The main goal of the work is to characterize safety and comfort issues that are fundamental to human inte...
Quek, Kia Fatt; Chua, Chong Beng; Razack, Azad Hassan; Low, Wah Yun; Loh, Chit Sin
2005-01-01
The purpose of the present study was to validate the Mandarin version of the International Prostate Symptom Score (Mand-IPSS) in a Malaysian population. The validity and reliability were studied in patients with lower urinary tract symptoms (LUTS; benign prostatic hyperplasia [BPH] group) and without LUTS (control group). Test-retest methodology was used to assess the reliability while Cronbach alpha was used to assess the internal consistency. Sensitivity to change was used to express the effect size index in the preintervention versus post-intervention score in patients with LUTS who underwent transurethral resection of the prostate. For the control group and BPH group, the internal consistency was excellent and a high degree of internal consistency was observed for all seven items (Cronbach alpha = 0.86-0.98 and 0.90-0.98, respectively). Test-retest correlation coefficients for all items were highly significant. Intraclass correlation coefficient (ICC) was high for the control (ICC = 0.93-0.99) and BPH group (ICC = 0.91-0.99). The sensitivity and specificity showed a high degree of sensitivity and specificity to the effects of treatment. A high degree of significance between baseline and post-treatment scores was observed across all seven items in the BPH group but not in the control group. The Mand-IPSS is a suitable, reliable, valid and sensitive instrument to measure clinical change in the Malaysian population.
The Practical Impact of Recent Computer Advances on the Analysis and Design of Large Scale Networks
1974-12-01
Communications, ICC-74, June 17-19, Minneapolis, Minnesota, pp. 31C-1-21C-5. 28. Gitman , I., R, M. Van Slvke and H. Frank, "On Splitting Random Access Broadcast...1974. 29. Gitman , I., "On the Capacity of Slotted ALOHA Network and Some Design Problems," IEEE Transactions on Communications, Maren, 1975. 30
Tatewaki, Yasuko; Higano, Shuichi; Taki, Yasuyuki; Thyreau, Benjamin; Murata, Takaki; Mugikura, Shunji; Ito, Daisuke; Takase, Kei; Takahashi, Shoki
2014-01-01
Quantitative signal targeting with alternating radiofrequency labeling of arterial regions (QUASAR) is a recent spin labeling technique that could improve the reliability of brain perfusion measurements. Although it is considered reliable for measuring gray matter as a whole, it has never been evaluated regionally. Here we assessed this regional reliability. Using a 3-Tesla Philips Achieva whole-body system, we scanned four times 10 healthy volunteers, in two sessions 2 weeks apart, to obtain QUASAR images. We computed perfusion images and ran a voxel-based analysis within all brain structures. We also calculated mean regional cerebral blood flow (rCBF) within regions of interest configured for each arterial territory distribution. The mean CBF over whole gray matter was 37.74 with intraclass correlation coefficient (ICC) of .70. In white matter, it was 13.94 with an ICC of .30. Voxel-wise ICC and coefficient-of-variation maps showed relatively lower reliability in watershed areas and white matter especially in deeper white matter. The absolute mean rCBF values were consistent with the ones reported from PET, as was the relatively low variability in different feeding arteries. Thus, QUASAR reliability for regional perfusion is high within gray matter, but uncertain within white matter. © 2014 The Authors. Journal of Neuroimaging published by the American Society of Neuroimaging.
Tatewaki, Yasuko; Higano, Shuichi; Taki, Yasuyuki; Thyreau, Benjamin; Murata, Takaki; Mugikura, Shunji; Ito, Daisuke; Takase, Kei; Takahashi, Shoki
2014-01-01
BACKGROUND AND PURPOSE Quantitative signal targeting with alternating radiofrequency labeling of arterial regions (QUASAR) is a recent spin labeling technique that could improve the reliability of brain perfusion measurements. Although it is considered reliable for measuring gray matter as a whole, it has never been evaluated regionally. Here we assessed this regional reliability. METHODS Using a 3-Tesla Philips Achieva whole-body system, we scanned four times 10 healthy volunteers, in two sessions 2 weeks apart, to obtain QUASAR images. We computed perfusion images and ran a voxel-based analysis within all brain structures. We also calculated mean regional cerebral blood flow (rCBF) within regions of interest configured for each arterial territory distribution. RESULTS The mean CBF over whole gray matter was 37.74 with intraclass correlation coefficient (ICC) of .70. In white matter, it was 13.94 with an ICC of .30. Voxel-wise ICC and coefficient-of-variation maps showed relatively lower reliability in watershed areas and white matter especially in deeper white matter. The absolute mean rCBF values were consistent with the ones reported from PET, as was the relatively low variability in different feeding arteries. CONCLUSIONS Thus, QUASAR reliability for regional perfusion is high within gray matter, but uncertain within white matter. PMID:25370338
Roque, Fátima; Soares, Sara; Breitenfeld, Luiza; Gonzalez-Gonzalez, Cristian; Figueiras, Adolfo; Herdeiro, Maria Teresa
2014-01-01
To develop and evaluate the reliability of a self-administered questionnaire designed to assess the attitudes and knowledge of community pharmacists in Portugal about microbial resistance and the antibiotic dispensing process. This study was divided into the following three stages: (1) design of the questionnaire, which included a literature review and a qualitative study with focus-group sessions; (2) assessment of face and content validity, using a panel of experts and a pre-test of community pharmacists; and, (3) pilot study and reliability analysis, which included a test-retest study covering fifty practising pharmacists based at community pharmacies in five districts situated in Northern Portugal. Questionnaire reproducibility was quantified using the intraclass correlation coefficient (ICC; 95% confidence interval) computed by means of one-way analysis of variance (ANOVA). Internal consistency was evaluated using Cronbach's alpha. The correlation coefficients were fair to good (ICC>0.4) for all statements (scale-items) regarding knowledge of and attitudes to antibiotic resistance, and ranged from fair to good to excellent for statements about situations in which pharmacists acknowledged that antibiotics were sometimes dispensed without a medical prescription (ICC>0.8). Cronbach's alpha for this section was 0.716. The questionnaire designed in this study is valid and reliable in terms of content validity, face validity and reproducibility.
Flour, Mieke; Clark, Michael; Partsch, Hugo; Mosti, Giovanni; Uhl, Jean-Francois; Chauveau, Michel; Cros, Francois; Gelade, Pierre; Bender, Dean; Andriessen, Anneke; Schuren, Jan; Cornu-Thenard, André; Arkans, Ed; Milic, Dragan; Benigni, Jean-Patrick; Damstra, Robert; Szolnoky, Gyozo; Schingale, Franz
2013-10-01
The International Compression Club (ICC) is a partnership between academics, clinicians and industry focused upon understanding the role of compression in the management of different clinical conditions. The ICC meet regularly and from these meetings have produced a series of eight consensus publications upon topics ranging from evidence-based compression to compression trials for arm lymphoedema. All of the current consensus documents can be accessed on the ICC website (http://www.icc-compressionclub.com/index.php). In May 2011, the ICC met in Brussels during the European Wound Management Association (EWMA) annual conference. With almost 50 members in attendance, the day-long ICC meeting challenged a series of dogmas and myths that exist when considering compression therapies. In preparation for a discussion on beliefs surrounding compression, a forum was established on the ICC website where presenters were able to display a summary of their thoughts upon each dogma to be discussed during the meeting. Members of the ICC could then provide comments on each topic thereby widening the discussion to the entire membership of the ICC rather than simply those who were attending the EWMA conference. This article presents an extended report of the issues that were discussed, with each dogma covered in a separate section. The ICC discussed 12 'dogmas' with areas 1 through 7 dedicated to materials and application techniques used to apply compression with the remaining topics (8 through 12) related to the indications for using compression. © 2012 The Authors. International Wound Journal © 2012 John Wiley & Sons Ltd and Medicalhelplines.com Inc.
Randomized controlled trial of anterior-chamber intraocular lenses in Nepal: long-term follow-up.
Evans, J. R.; Henning, A.; Pradhan, D.; Foster, A.; Lagnado, R.; Poulson, A.; Johnson, G. J.; Wormald, R. P.
2000-01-01
Most of the estimated 20 million people who are blind with cataracts live in rural areas of developing countries, where expert surgical resources are scarce. We have studied the use of multiflex open-loop anterior-chamber intraocular lenses (ACIOL) in high-volume low-cost surgery. Between 1992 and 1995, a total of 2000 people attending Lahan Eye Hospital, Nepal, with bilateral cataracts reducing vision to < or = 6/36 were randomly allocated to receive intracapsular extraction (ICCE) with aphakic spectacles, or ICCE with an ACIOL. We re-examined the cohort (1305/2000, 65%) between November 1996 and April 1997 and report the findings in this article. There were 13 new cases of poor visual outcome (best corrected vision < 6/60) arising after one year: 9 in the ACIOL group and 4 in the control group; odds ratio 2.1 (95% confidence interval, 0.59-9.55). The causes of poor outcome were as follows: ACIOL group--retinal detachment (4 cases), cystoid macular oedema (2), epiretinal membrane (1), age-related macular degeneration (1), and late endophthalmitis (1); control group--retinal detachment (2 cases), late endophthalmitis (1), and primary open-angle glaucoma with age-related macular degeneration (1). In rural areas of developing countries, well-manufactured multiflex open-loop ACIOLs can be implanted safely by experienced ophthalmologists after routine ICCE, avoiding the disadvantages of aphakic spectacle correction. PMID:10812737
Test-Retest Reliability of Diffusion Tensor Imaging in Huntington's Disease.
Cole, James H; Farmer, Ruth E; Rees, Elin M; Johnson, Hans J; Frost, Chris; Scahill, Rachael I; Hobbs, Nicola Z
2014-03-21
Diffusion tensor imaging (DTI) has shown microstructural abnormalities in patients with Huntington's Disease (HD) and work is underway to characterise how these abnormalities change with disease progression. Using methods that will be applied in longitudinal research, we sought to establish the reliability of DTI in early HD patients and controls. Test-retest reliability, quantified using the intraclass correlation coefficient (ICC), was assessed using region-of-interest (ROI)-based white matter atlas and voxelwise approaches on repeat scan data from 22 participants (10 early HD, 12 controls). T1 data was used to generate further ROIs for analysis in a reduced sample of 18 participants. The results suggest that fractional anisotropy (FA) and other diffusivity metrics are generally highly reliable, with ICCs indicating considerably lower within-subject compared to between-subject variability in both HD patients and controls. Where ICC was low, particularly for the diffusivity measures in the caudate and putamen, this was partly influenced by outliers. The analysis suggests that the specific DTI methods used here are appropriate for cross-sectional research in HD, and give confidence that they can also be applied longitudinally, although this requires further investigation. An important caveat for DTI studies is that test-retest reliability may not be evenly distributed throughout the brain whereby highly anisotropic white matter regions tended to show lower relative within-subject variability than other white or grey matter regions.
Gray, Heewon Lee; Burgermaster, Marissa; Tipton, Elizabeth; Contento, Isobel R; Koch, Pamela A; Di Noia, Jennifer
2016-04-01
Sample size and statistical power calculation should consider clustering effects when schools are the unit of randomization in intervention studies. The objective of the current study was to investigate how student outcomes are clustered within schools in an obesity prevention trial. Baseline data from the Food, Health & Choices project were used. Participants were 9- to 13-year-old students enrolled in 20 New York City public schools (n= 1,387). Body mass index (BMI) was calculated based on measures of height and weight, and body fat percentage was measured with a Tanita® body composition analyzer (Model SC-331s). Energy balance-related behaviors were self-reported with a frequency questionnaire. To examine the cluster effects, intraclass correlation coefficients (ICCs) were calculated as school variance over total variance for outcome variables. School-level covariates, percentage students eligible for free and reduced-price lunch, percentage Black or Hispanic, and English language learners were added in the model to examine ICC changes. The ICCs for obesity indicators are: .026 for BMI-percentile, .031 for BMIz-score, .035 for percentage of overweight students, .037 for body fat percentage, and .041 for absolute BMI. The ICC range for the six energy balance-related behaviors are .008 to .044 for fruit and vegetables, .013 to .055 for physical activity, .031 to .052 for recreational screen time, .013 to .091 for sweetened beverages, .033 to .121 for processed packaged snacks, and .020 to .083 for fast food. When school-level covariates were included in the model, ICC changes varied from -95% to 85%. This is the first study reporting ICCs for obesity-related anthropometric and behavioral outcomes among New York City public schools. The results of the study may aid sample size estimation for future school-based cluster randomized controlled trials in similar urban setting and population. Additionally, identifying school-level covariates that can reduce cluster effects is important when analyzing data. © 2015 Society for Public Health Education.
Development of a reliable method to assess footwear comfort during running.
Mündermann, Anne; Nigg, Benno M; Stefanyshyn, Darren J; Humble, R Neil
2002-08-01
The purposes of this study were: (a) to determine whether subjects are able to distinguish between differences in footwear with respect to footwear comfort; and (b) to determine how reliably footwear comfort can be assessed using a visual analogue scale (VAS) and a protocol including a control condition during running. Intraclass correlation coefficients (ICCs) between comfort ratings for repeated conditions were high (ICC = 0.799). Differences in comfort ratings between the insert conditions were significant. A paired t-test revealed a significant difference in overall comfort ratings for the control insert when tested after the soft insert compared to when tested after the hard insert (P = 0.008). The results of this study showed that VASs provide a reliable measure to assess footwear comfort during running under the conditions that: (a) a control condition is included; and (b) the average comfort rating of sessions 4-6 is used. Copyright 2002 Elsevier Science B.V.
Intelligent cruise control field operational test. Vol II, Appendices A-F
DOT National Transportation Integrated Search
1998-05-01
This document reports on a cooperative agreement between NHTSA and UMTRI entitled Intelligent Cruise Control (ICC) Field Operational Test (FOT). The main goal of the work is to characterize safety and comfort issues that are fundamental to human inte...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 24 2011-07-01 2011-07-01 false Trichoderma asperellum strain ICC 012... RESIDUES IN FOOD Exemptions From Tolerances § 180.1294 Trichoderma asperellum strain ICC 012; exemption from the requirement of a tolerance. Trichoderma asperellum strain ICC 012 is exempted from the...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Trichoderma asperellum strain ICC 012... RESIDUES IN FOOD Exemptions From Tolerances § 180.1294 Trichoderma asperellum strain ICC 012; exemption from the requirement of a tolerance. Trichoderma asperellum strain ICC 012 is exempted from the...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 25 2012-07-01 2012-07-01 false Trichoderma asperellum strain ICC 012... RESIDUES IN FOOD Exemptions From Tolerances § 180.1294 Trichoderma asperellum strain ICC 012; exemption from the requirement of a tolerance. Trichoderma asperellum strain ICC 012 is exempted from the...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 24 2014-07-01 2014-07-01 false Trichoderma asperellum strain ICC 012... RESIDUES IN FOOD Exemptions From Tolerances § 180.1294 Trichoderma asperellum strain ICC 012; exemption from the requirement of a tolerance. Trichoderma asperellum strain ICC 012 is exempted from the...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 25 2013-07-01 2013-07-01 false Trichoderma asperellum strain ICC 012... RESIDUES IN FOOD Exemptions From Tolerances § 180.1294 Trichoderma asperellum strain ICC 012; exemption from the requirement of a tolerance. Trichoderma asperellum strain ICC 012 is exempted from the...
Jeong, Seogsong; Tong, Ying; Sha, Meng; Gu, Jinyang; Xia, Qiang
2017-03-07
It has been a decade since hepatitis B virus infection was identified as an etiological factor for the development of intrahepatic cholangiocarcinoma (ICC). In recent years, several studies have elucidated the critical impact of hepatitis B virus in ICC that significantly influenced the clinicopathological characteristics of ICC patients with intrahepatic cholangiocarcinoma. Distinctive features of patients with hepatitis B virus-associated ICC included younger age, preponderance of male patients, frequent elevation of alpha-fetoprotein, and infrequent lymph node metastasis. Furthermore, several studies indicated that the presence of hepatitis B virus is a favorable prognostic factor in terms of overall survival and relapse-free survival. However, there are also a few studies demonstrating that hepatitis B virus negatively influenced or showed no significant association with survival outcomes of patients with ICC. At present, there are no consensus on diagnostic procedures and treatments for such population. Therefore, we elucidated current knowledge and recent identifications of HBV-associated ICC to clarify the impact of chronic HBV infection on patients with ICC and to precisely conduct diagnostic procedures and curative treatments for HBV-associated ICC.
Yu, Guang-Yang; Wang, Xuan; Zheng, Su-Su; Gao, Xiao-Mei; Jia, Qing-An; Zhu, Wen-Wei; Lu, Lu; Jia, Hu-Liang; Chen, Jin-Hong; Dong, Qiong-Zhu; Lu, Ming; Qin, Lun-Xiu
2018-06-15
Effective drug treatment for intrahepatic cholangiocarcinoma (ICC) is currently lacking. Therefore, there is an urgent need for new targets and new drugs that can prolong patient survival. Recently targeting the ubiquitin proteasome pathway has become an attractive anti-cancer strategy. In this study, we aimed to evaluate the therapeutic effect of and identify the potential mechanisms involved in targeting the proteasome subunit ADRM1 for ICC. The expression of ADRM1 and its prognostic value in ICC was analyzed using GEO and TCGA datasets, tumor tissues, and tumor tissue arrays. The effects of RA190 on the proliferation and survival of both established ICC cell lines and primary ICC cells were examined in vitro. Annexin V/propidium iodide staining, western blotting and immunohistochemical staining were performed. The in vivo anti-tumor effect of RA190 on ICC was validated in subcutaneous xenograft and patient-derived xenograft (PDX) models. ADRM1 levels were significantly higher in ICC tissues than in normal bile duct tissues. ICC patients with high ADRM1 levels had worse overall survival (hazard ratio [HR] = 2.383, 95% confidence interval [CI] =1.357 to 4.188) and recurrence-free survival (HR = 1.710, 95% CI =1.045 to 2.796). ADRM1 knockdown significantly inhibited ICC growth in vitro and in vivo. The specific inhibitor RA190 targeting ADRM1 suppressed proliferation and reduced cell vitality of ICC cell lines and primary ICC cells significantly in vitro. Furthermore, RA190 significantly inhibited the proteasome by inactivating ADRM1, and the consequent accumulation of ADRM1 substrates decreased the activating levels of NF-κB to aggravate cell apoptosis. The therapeutic benefits of RA190 treatment were further demonstrated in both subcutaneous implantation and PDX models. Our findings indicate that up-regulated ADRM1 was involved in ICC progression and suggest the potential clinical application of ADRM1 inhibitors (e.g., RA190 and KDT-11) for ICC treatment. © 2018 The Author(s). Published by S. Karger AG, Basel.
Farioli, Andrea; Straif, Kurt; Brandi, Giovanni; Curti, Stefania; Kjaerheim, Kristina; Martinsen, Jan Ivar; Sparen, Pär; Tryggvadottir, Laufey; Weiderpass, Elisabete; Biasco, Guido; Violante, Francesco Saverio; Mattioli, Stefano; Pukkala, Eero
2018-01-01
Objectives To assess the association between occupational exposure to asbestos and the risk of cholangiocarcinoma (CC). Methods We conducted a case–control study nested in the Nordic Occupational Cancer (NOCCA) cohort. We studied 1458 intrahepatic CC (ICC) and 3972 extrahepatic CC (ECC) cases occurring among subjects born in 1920 or later in Finland, Iceland, Norway and Sweden. Each case was individually matched by birth year, gender and country to five population controls. The cumulative exposure to asbestos (measured in fibres (f)/ml × years) was assessed by applying the NOCCA job-exposure matrix to data on occupations collected during national population censuses (conducted in 1960, 1970, 1980/81 and 1990). Odds ratios (OR) and 95% CI were estimated using conditional logistic regression models adjusted by printing industry work. Results We observed an increasing risk of ICC with cumulative exposure to asbestos: never exposed, OR 1.0 (reference category); 0.1–4.9 f/mL × years, OR 1.1 (95% CI 0.9 to 1.3); 5.0–9.9 f/mL × years, OR 1.3 (95% CI 0.9 to 2.1); 10.0–14.9 f/mL × years, OR 1.6 (95% CI 1.0 to 2.5); ≥15.0 f/mL × years, OR 1.7 (95% CI 1.1 to 2.6). We did not observe an association between cumulative asbestos exposure and ECC. Conclusions Our study provides evidence that exposure to asbestos might be a risk factor for ICC. Our findings also suggest that the association between ECC and asbestos is null or weaker than that observed for ICC. Further studies based on large industrial cohorts of asbestos workers and possibly accounting for personal characteristics and clinical history are needed. PMID:29133597
Farioli, Andrea; Straif, Kurt; Brandi, Giovanni; Curti, Stefania; Kjaerheim, Kristina; Martinsen, Jan Ivar; Sparen, Pär; Tryggvadottir, Laufey; Weiderpass, Elisabete; Biasco, Guido; Violante, Francesco Saverio; Mattioli, Stefano; Pukkala, Eero
2018-03-01
To assess the association between occupational exposure to asbestos and the risk of cholangiocarcinoma (CC). We conducted a case-control study nested in the Nordic Occupational Cancer (NOCCA) cohort. We studied 1458 intrahepatic CC (ICC) and 3972 extrahepatic CC (ECC) cases occurring among subjects born in 1920 or later in Finland, Iceland, Norway and Sweden. Each case was individually matched by birth year, gender and country to five population controls. The cumulative exposure to asbestos (measured in fibres (f)/ml × years) was assessed by applying the NOCCA job-exposure matrix to data on occupations collected during national population censuses (conducted in 1960, 1970, 1980/81 and 1990). Odds ratios (OR) and 95% CI were estimated using conditional logistic regression models adjusted by printing industry work. We observed an increasing risk of ICC with cumulative exposure to asbestos: never exposed, OR 1.0 (reference category); 0.1-4.9 f/mL × years, OR 1.1 (95% CI 0.9 to 1.3); 5.0-9.9 f/mL × years, OR 1.3 (95% CI 0.9 to 2.1); 10.0-14.9 f/mL × years, OR 1.6 (95% CI 1.0 to 2.5); ≥15.0 f/mL × years, OR 1.7 (95% CI 1.1 to 2.6). We did not observe an association between cumulative asbestos exposure and ECC. Our study provides evidence that exposure to asbestos might be a risk factor for ICC. Our findings also suggest that the association between ECC and asbestos is null or weaker than that observed for ICC. Further studies based on large industrial cohorts of asbestos workers and possibly accounting for personal characteristics and clinical history are needed. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Jesus, Gilmar Mercês de; Assis, Maria Alice Altenburg de; Kupek, Emil; Dias, Lizziane Andrade
2017-01-01
The quality control of data entry in computerized questionnaires is an important step in the validation of new instruments. The study assessed the consistency of recorded weight and height on the Food Intake and Physical Activity of School Children (Web-CAAFE) between repeated measures and against directly measured data. Students from the 2nd to the 5th grade (n = 390) had their weight and height directly measured and then filled out the Web-CAAFE. A subsample (n = 92) filled out the Web-CAAFE twice, three hours apart. The analysis included hierarchical linear regression, mixed linear regression model, to evaluate the bias, and intraclass correlation coefficient (ICC), to assess consistency. Univariate linear regression assessed the effect of gender, reading/writing performance, and computer/internet use and possession on residuals of fixed and random effects. The Web-CAAFE showed high values of ICC between repeated measures (body weight = 0.996, height = 0.937, body mass index - BMI = 0.972), and regarding the checked measures (body weight = 0.962, height = 0.882, BMI = 0.828). The difference between means of body weight, height, and BMI directly measured and recorded was 208 g, -2 mm, and 0.238 kg/m², respectively, indicating slight BMI underestimation due to underestimation of weight and overestimation of height. This trend was related to body weight and age. Height and weight data entered in the Web-CAAFE by children were highly correlated with direct measurements and with the repeated entry. The bias found was similar to validation studies of self-reported weight and height in comparison to direct measurements.
40 CFR 180.1293 - Trichoderma gamsii strain ICC 080; exemption from the requirement of a tolerance.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Trichoderma gamsii strain ICC 080... RESIDUES IN FOOD Exemptions From Tolerances § 180.1293 Trichoderma gamsii strain ICC 080; exemption from the requirement of a tolerance. Trichoderma gamsii strain ICC 080 is exempted from the requirement of...
40 CFR 180.1293 - Trichoderma gamsii strain ICC 080; exemption from the requirement of a tolerance.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 24 2011-07-01 2011-07-01 false Trichoderma gamsii strain ICC 080... RESIDUES IN FOOD Exemptions From Tolerances § 180.1293 Trichoderma gamsii strain ICC 080; exemption from the requirement of a tolerance. Trichoderma gamsii strain ICC 080 is exempted from the requirement of...
40 CFR 180.1293 - Trichoderma gamsii strain ICC 080; exemption from the requirement of a tolerance.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 24 2014-07-01 2014-07-01 false Trichoderma gamsii strain ICC 080... RESIDUES IN FOOD Exemptions From Tolerances § 180.1293 Trichoderma gamsii strain ICC 080; exemption from the requirement of a tolerance. Trichoderma gamsii strain ICC 080 is exempted from the requirement of...
40 CFR 180.1293 - Trichoderma gamsii strain ICC 080; exemption from the requirement of a tolerance.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 25 2012-07-01 2012-07-01 false Trichoderma gamsii strain ICC 080... RESIDUES IN FOOD Exemptions From Tolerances § 180.1293 Trichoderma gamsii strain ICC 080; exemption from the requirement of a tolerance. Trichoderma gamsii strain ICC 080 is exempted from the requirement of...
40 CFR 180.1293 - Trichoderma gamsii strain ICC 080; exemption from the requirement of a tolerance.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 25 2013-07-01 2013-07-01 false Trichoderma gamsii strain ICC 080... RESIDUES IN FOOD Exemptions From Tolerances § 180.1293 Trichoderma gamsii strain ICC 080; exemption from the requirement of a tolerance. Trichoderma gamsii strain ICC 080 is exempted from the requirement of...
NASA Astrophysics Data System (ADS)
Jin, Dakai; Guo, Junfeng; Dougherty, Timothy M.; Iyer, Krishna S.; Hoffman, Eric A.; Saha, Punam K.
2016-03-01
Pulmonary vascular dysfunction has been implicated in smoking-related susceptibility to emphysema. With the growing interest in characterizing arterial morphology for early evaluation of the vascular role in pulmonary diseases, there is an increasing need for the standardization of a framework for arterial morphological assessment at airway segmental levels. In this paper, we present an effective and robust semi-automatic framework to segment pulmonary arteries at different anatomic airway branches and measure their cross-sectional area (CSA). The method starts with user-specified endpoints of a target arterial segment through a custom-built graphical user interface. It then automatically detect the centerline joining the endpoints, determines the local structure orientation and computes the CSA along the centerline after filtering out the adjacent pulmonary structures, such as veins or airway walls. Several new techniques are presented, including collision-impact based cost function for centerline detection, radial sample-line based CSA computation, and outlier analysis of radial distance to subtract adjacent neighboring structures in the CSA measurement. The method was applied to repeat-scan pulmonary multirow detector CT (MDCT) images from ten healthy subjects (age: 21-48 Yrs, mean: 28.5 Yrs; 7 female) at functional residual capacity (FRC). The reproducibility of computed arterial CSA from four airway segmental regions in middle and lower lobes was analyzed. The overall repeat-scan intra-class correlation (ICC) of the computed CSA from all four airway regions in ten subjects was 96% with maximum ICC found at LB10 and RB4 regions.
2007-11-03
KENNEDY SPACE CENTER, FLA. -- In the Space Station Processing Facility at NASA's Kennedy Space Center, an overhead crane moves the integrated cargo carrier-lite, or ICC-L, into the payload canister below. The ICC-L is an unpressurized cross-bay carrier providing launch and return transportation with the space shuttle. It rests on a keel yoke assembly, seen underneath. The ICC-L carries three elements: a nitrogen tank assembly that is part of the external active thermal control system on the International Space Station, the European technology Exposure Facility composed of nine science instruments and an autonomous temperature measurement unit, and the SOLAR payload designed for sun observation. The nitrogen tank assembly is mounted underneath. The exposure facility is seen at left on top, and the SOLAR is on the right. The SOLAR will be transferred and stowed on the Columbus module during the third spacewalk of the mission. STS-122 is targeted for launch on Dec. 6 on space shuttle Atlantis. Photo credit: NASA/Amanda Diller
2007-11-03
KENNEDY SPACE CENTER, FLA. -- In the Space Station Processing Facility at NASA's Kennedy Space Center, an overhead crane moves the integrated cargo carrier-lite, or ICC-L, into the payload canister below. The ICC-L is an unpressurized cross-bay carrier providing launch and return transportation with the space shuttle. It rests on a keel yoke assembly, seen underneath. The ICC-L carries three elements: a nitrogen tank assembly that is part of the external active thermal control system on the International Space Station, the European technology Exposure Facility composed of nine science instruments and an autonomous temperature measurement unit, and the SOLAR payload designed for sun observation. The nitrogen tank assembly is mounted underneath. The exposure facility is seen at left on top, and the SOLAR is on the right. The SOLAR will be transferred and stowed on the Columbus module during the third spacewalk of the mission. STS-122 is targeted for launch on Dec. 6 on space shuttle Atlantis. Photo credit: NASA/Amanda Diller
Goniometric reliability in a clinical setting. Shoulder measurements.
Riddle, D L; Rothstein, J M; Lamb, R L
1987-05-01
The purpose of this study was to examine the intratester and intertester reliabilities for clinical goniometric measurements of shoulder passive range of motion (PROM) using two different sizes of universal goniometers. Patients were measured without controlling therapist goniometric placement technique or patient position during measurements. Repeated PROM measurements of shoulder flexion, extension, abduction, shoulder horizontal abduction, horizontal adduction, lateral (external) rotation, and medial (internal) rotation were taken of two groups of 50 subjects each. The intratester intraclass correlation coefficients (ICCs) for all motions ranged from .87 to .99. The ICCs for the intertester reliability of PROM measurements of horizontal abduction, horizontal adduction, extension, and medial rotation ranged from .26 to .55. The intertester ICCs for PROM measurements of flexion, abduction, and lateral rotation ranged from .84 to .90. Goniometric PROM measurements for the shoulder appear to be highly reliable when taken by the same physical therapist, regardless of the size of the goniometer used. The degree of intertester reliability for these measurements appears to be range-of-motion specific.
The role of interventional radiology in the treatment of intrahepatic cholangiocarcinoma.
Ierardi, Anna Maria; Angileri, Salvatore Alessio; Patella, Francesca; Panella, Silvia; Lucchina, Natalie; Petre, Elena N; Pinto, Antonio; Franceschelli, Giuseppe; Carrafiello, Gianpaolo; Cornalba, Gianpaolo; Sofocleous, Constantinos T
2017-01-01
Intrahepatic cholangiocarcinoma (ICC) is the second most common primary hepatic malignancy after hepatocellular carcinoma. Complete surgical resection remains the only potentially curative option for patients with ICC. However, until now, early diagnosis with potential surgical intervention has been the exception rather than the rule with only 30% of patients qualifying for attempted surgical cure. Many patients are unresectable because of disease stage, anatomic conditions, medical comorbidities, and small future remnant liver. Interventional radiology procedures are available for these types of patients with intra-arterial therapies and/or ablative treatments both for curative and for palliative treatment. The goals of interventional therapy are to control local tumor growth, to relieve symptoms, and to improve and preserve quality of life. The choice of treatment depends largely on tumor extent and patient performance. No randomized studies exist to compare treatments. The present review describes the current evidence of the interventional treatments in the management of the ICC. Moreover, interventional procedures available to increase the future liver reserve before surgery were analyzed.
Tadele, Agerie; Beyene, Demissew; Hussein, Jemal; Gemechu, Tuffa; Birhanu, Asaye; Mustafa, Tehmina; Tsegaye, Aster; Aseffa, Abraham; Sviland, Lisbet
2014-11-25
A rapid, sensitive and accurate laboratory diagnosis is of prime importance in suspected extrapulmonary tuberculosis (EPTB) cases. However, traditional techniques for the detection of acid-fast bacilli have limitations. The aim of the study was to evaluate the diagnostic value of immunocytochemical staining for detection of Mycobacterium tuberculosis complex specific antigen, MPT64, in aspirates from pleural effusions and lymph nodes, the most common presentations of EPTB. A cross-sectional study was conducted by including patients at Tikur Anbessa Specialized Hospital and the United Vision Medical Services from December 2011 to June 2012. Lymph node aspirates and pleural fluid samples were collected and analyzed from a total of 51 cases (26 tuberculous (TB) pleuritis and 25 TB lymphadenitis) and 67 non-TB controls. Each specimen was subjected to Ziehl-Neelsen (ZN) staining, culture on Lowenstein- Jensen (LJ) medium, cytological examination, Polymerase Chain Reaction (PCR) using IS1081gene sequence as a primer and immunocytochemistry (ICC) with polyclonal anti-MPT64 antibody. All patients were screened for HIV. ICC was positive in 38 of 51 cases and in the 7 of 67 controls giving an overall sensitivity and specificity of 74.5% and 89.5%, respectively. Using IS1081-PCR as a reference method, the sensitivity and specificity, positive and negative predictive value of ICC was 88.1%, 89.5%, 82.2% and 93.2%, respectively. The case detection rate increased from 13.7% by ZN stain to 19.6% by LJ culture, to 66.7% by cytology and 74.5% by ICC. Immunocytochemistry with anti-MPT64 antigen improved detection of TB in pleural effusion and lymph node aspirates. Further studies using monoclonal antibodies on samples from other sites of EPTB is recommended to validate this relatively simple diagnostic method for EPTB.
Chen, Binrui; Zhu, Shuwen; Du, Lijun; He, Huiqin; Kim, John J; Dai, Ning
2017-10-01
Intestinal dysmotility and immune activation are likely involved in the pathogenesis of small intestinal bacteria overgrowth (SIBO) in irritable bowel syndrome (IBS). We aimed at investigating the role of interstitial cells of Cajal (ICC) and intestinal inflammation in the development of SIBO using a post-infectious IBS (PI-IBS) mouse model. NIH mice were randomly infected with Trichinella spiralis. Visceral sensitivity and stool pattern were assessed at 8-weeks post-infection (PI). Intestinal bacteria counts from jejunum and ileum were measured by quantitative real-time PCR to evaluate the presence of SIBO. ICC density, intraepithelial lymphocytes (IELs) counts, and intestinal cytokine levels (IL1-β, IL-6, toll-like receptor-4 (TLR-4), IL-10) in the ileum were examined. PI-IBS mice demonstrated increased visceral sensitivity compared with the control group. One-third of the PI-IBS mice developed SIBO (SIBO+/PI-IBS) and was more likely to have abnormal stool form compared with SIBO negative PI-IBS (SIBO-/PI-IBS) mice but without difference in visceral sensitivity. SIBO+/PI-IBS mice had decreased ICC density and increased IELs counts in the ileum compared with SIBO-/PI-IBS mice. No difference in inflammatory cytokine expression levels were detected among the groups except for increased TLR-4 in PI-IBS mice compared with the control group. Development of SIBO in PI-IBS mice was associated with reduced ICC density and increased IELs counts in the ileum. Our findings support the role of intestinal dysmotility and inflammation in the pathogenesis of SIBO in IBS and may provide potential therapeutic targets.
Piqué-Vidal, Carlos; Maled-García, Ignaci; Arabi-Moreno, Juanjo; Vila, Joan
2006-03-01
The objective of this study was to compare angular measurements in the evaluation of hallux valgus deformities using a goniometer and a computerized program to assess degree of concordance between the two methods and determine the reliability of manual measurements. Angles measured included the hallux valgus angle (HVA), the intermetatarsal angle (IMA), the distal metatarsal articular angle (DMAA), and the proximal phalangeal articular angle (PPAA), also called the hallux valgus interphalangeus angle or interphalangeal angle. Measurements were made on preoperative weightbearing radiographs in 176 patients with symptomatic hallux valgus. Manual measurements were made with a goniometer by an orthopaedic surgeon. An independent experienced technician used digitized images to perform angular measurements with the Autocad software program (Autodesk Inc., San Rafael, CA). HVA values obtained with the two techniques were similar. However, significantly higher mean values were obtained with the Autocad for the IMA and PPAA measurements, and higher mean values were obtained for the DMAA measurement with the manual technique. Whereas differences were more or less randomly distributed for the HVA, in the remaining patients, measurements were clearly related to the measurement technique, i.e., for the DMAA, the manual technique had a tendency to show higher values, and for the IMA and PPAA the manual technique showed lower values than the computer. Correlations between both techniques for the different angular measurements were as follows: HVA, -0.179 (p = 0.018); DMMA, -0.294 (p < 0.001); PPAA, -0.876 (p < 0.001); and IMA, -0.661 (p < 0.001). The intraclass correlation coefficient (ICC) showed that the concordance between manual and Autocad angular measurements was excellent for the HVA (ICC = 0.89) and DMAA (ICC = 0.80) and very poor for the PPAA (ICC = 0.11) and IMA (ICC = 0.42). Angular measurements made on weightbearing radiographs with the Autocad in patients with hallux valgus deformities were more reliable than those made with a goniometer. Although for large angles, such as HVA and DMAA, results obtained with both measurement techniques were similar. Manual measurements, however, may underestimate the true values of the smaller IMA and PPAA angles.
Maloca, Peter; Gyger, Cyrill; Schoetzau, Andreas; Hasler, Pascal W
2015-11-01
We measured reproducibility of speckle-noise freed fluid and tissue compartmentalization of the choroid (choroidal angiography and tissue characterization). This study included 26 eyes of 13 healthy females: 13 were used for repeated measurements and 13 were used for side comparison. A semiautomated algorithm removed speckle-noise with structure preservation. Intraclass correlation (ICC), with respect to reproducibility of the method, showed an ICC for choroidal fluid inner space analysis (FISA) of 95.15% (90.01-98.24). The ICC of tissue inner space analysis (TISA) was 99.75% (99.47-99.91). The total choroid ratio (TCR), calculated from volumes of tissue to vessels, showed an ICC of 88.84% (78.28-95.82). Comparison of eyes (left to right) showed a difference for FISA of 0.033 (95% confidence interval [CI] -0.0018-0.0680, P = 0.063), TISA -0.118 (CI -0.2373-0.0023, P = 0.055), and TCR -0.590 (CI -0.9047 to -0.2754, P = 0.004). The ICC for FISA and TISA showed a trend in the difference comparing left and right eyes; however, TCR showed a significant difference between the eyes in the measured area ( P < 0.001). Mean overall FISA was 0.58 mm 3 (range, 0.25-0.98 mm 3 , SD = 0.14). Mean TISA was 3.45 mm 3 (range, 2.38-5.0 mm 3 , SD 0.072). Mean TCR was 6.13 (overall range, 3.93-10.2, SD = 1.34). Differences in choroidal layers between subjects were found mainly due to alterations in choroidal tissue. Reproducibility of speckle-noise freed choroidal angiography appeared excellent. Speckle noise is a granular "noise" that appears in a wide range of medical imaging methods as ultrasonography, magnetic resonance, computer tomography, or optical coherence tomography (OCT). Findings from basic science about speckle noise were translated into a novel, medical image postprocessing application that can separate signal from speckle noise with structure preservation with high reproducibility and enhance medical imaging.
Maloca, Peter; Gyger, Cyrill; Schoetzau, Andreas; Hasler, Pascal W.
2015-01-01
Purpose We measured reproducibility of speckle-noise freed fluid and tissue compartmentalization of the choroid (choroidal angiography and tissue characterization). Methods This study included 26 eyes of 13 healthy females: 13 were used for repeated measurements and 13 were used for side comparison. A semiautomated algorithm removed speckle-noise with structure preservation. Results Intraclass correlation (ICC), with respect to reproducibility of the method, showed an ICC for choroidal fluid inner space analysis (FISA) of 95.15% (90.01–98.24). The ICC of tissue inner space analysis (TISA) was 99.75% (99.47–99.91). The total choroid ratio (TCR), calculated from volumes of tissue to vessels, showed an ICC of 88.84% (78.28–95.82). Comparison of eyes (left to right) showed a difference for FISA of 0.033 (95% confidence interval [CI] −0.0018–0.0680, P = 0.063), TISA −0.118 (CI −0.2373–0.0023, P = 0.055), and TCR −0.590 (CI −0.9047 to −0.2754, P = 0.004). The ICC for FISA and TISA showed a trend in the difference comparing left and right eyes; however, TCR showed a significant difference between the eyes in the measured area (P < 0.001). Mean overall FISA was 0.58 mm3 (range, 0.25–0.98 mm3, SD = 0.14). Mean TISA was 3.45 mm3 (range, 2.38–5.0 mm3, SD 0.072). Mean TCR was 6.13 (overall range, 3.93–10.2, SD = 1.34). Conclusions Differences in choroidal layers between subjects were found mainly due to alterations in choroidal tissue. Reproducibility of speckle-noise freed choroidal angiography appeared excellent. Translational Relevance Speckle noise is a granular “noise” that appears in a wide range of medical imaging methods as ultrasonography, magnetic resonance, computer tomography, or optical coherence tomography (OCT). Findings from basic science about speckle noise were translated into a novel, medical image postprocessing application that can separate signal from speckle noise with structure preservation with high reproducibility and enhance medical imaging. PMID:26629399
Test-retest reliability of cardinal plane isokinetic hip torque and EMG.
Claiborne, Tina L; Timmons, Mark K; Pincivero, Danny M
2009-10-01
The objective of the present study was to establish test-retest reliability of isokinetic hip torque and prime mover electromyogram (EMG) through the three cardinal planes of motion. Thirteen healthy young adults participated in two experimental sessions, separated by approximately one week. During each session, isokinetic hip torque was evaluated on the Biodex Isokinetic Dynamometer at a velocity of 60 deg/s. Subjects performed three maximal-effort concentric and eccentric contractions, separately, for right and left hip abduction/adduction, flexion/extension, and internal/external rotation. Surface EMGs were sampled from the gluteus maximus, gluteus medius, adductor, medial and lateral hamstring, and rectus femoris muscles during all contractions. Intraclass correlation coefficients (ICC - 2,1) and standard errors of measurement (SEM) were calculated for peak torque for each movement direction and contraction mode, while ICCs were only computed for the EMG data. Motions that demonstrated high torque reliability included concentric hip abduction (right and left), flexion (right and left), extension (right) and internal rotation (right and left), and eccentric hip abduction (left), adduction (left), flexion (right), and extension (right and left) (ICC range=0.81-0.91). Motions with moderate torque reliability included concentric hip adduction (right), extension (left), internal rotation (left), and external rotation (right), and eccentric hip abduction and adduction (right), flexion (left), internal rotation (right and left), and external rotation (right and left) (ICC range=0.49-0.79). The majority of the EMG sampled muscles (n=12 and n=11 for concentric and eccentric contractions, respectively) demonstrated high reliability (ICC=0.81-0.95). Instances of low, or unacceptable, EMG reliability values occurred for the medial hamstring muscle of the left leg (both contraction modes) and the adductor muscle of the right leg during eccentric internal rotation. The major finding revealed high and moderate levels of between-day reliability of isokinetic hip peak torque and prime mover EMG. It is recommended that the day-to-day variability estimates concomitant with acceptable levels of reliability be considered when attempting to objectify intervention effects on hip muscle performance.
Communicating and understanding the purpose of pediatric phase I cancer trials.
Cousino, Melissa K; Zyzanski, Stephen J; Yamokoski, Amy D; Hazen, Rebecca A; Baker, Justin N; Noll, Robert B; Rheingold, Susan R; Geyer, J Russell; Alexander, Stewart C; Drotar, Dennis; Kodish, Eric D
2012-12-10
Quality informed consent should provide a clear understanding of the purpose of the research. Given the ethical challenges of pediatric phase I cancer trials, it is important to investigate physician-parent communication during informed consent conferences (ICCs) and parental understanding of the purpose of these studies. In the multisite Informed Consent in Pediatric Phase I Cancer Trials study, 85 ICCs for phase I research between June 2008 and May 2011 were directly observed, and 60 parents were subsequently interviewed. The scientific purpose was defined as composite understanding of drug safety, dose finding, and dose escalation. We determined the frequency with which physicians explained these and other phase I-related concepts during the ICC. Parent interviews were analyzed to determine understanding. The child was present at 83 of 85 ICCs. Only 32% of parents demonstrated substantial understanding of the scientific purpose of phase I cancer trials; 35% demonstrated little or no understanding. Parents of higher socioeconomic status and racial majority status were more likely to understand the scientific purpose. Factors associated with understanding included physician explanation of the goal of the applicable phase I protocol offered (explained in 85% of ICCs) and explanation of the dose cohorts (explained in 43% of ICCs). Physicians explained drug safety in 23% of ICCs, dose finding in 52% of ICCs, and dose escalation in 53% of ICCs. Many parents of children participating in phase I trials do not understand the purpose of these trials. Physician-parent communication about the purpose of phase I research is lacking during ICCs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xiong, Xinkui; Sun, Daoyi; Chai, Hao
The dysregulation of micro (mi)RNAs is associated with cancer development. The miRNA miR-145 is downregulated in intrahepatic cholangiocarcinoma (ICC); however, its precise role in tumor progression has not yet been elucidated. Novel (nua) kinase family (NUAK)1 functions as an oncogene in various cancers and is a putative target of miR-145 regulation. In this study, we investigated the regulation of NUAK1 by miR-145 in ICC. We found that miR-145 level was significantly decreased in ICC tissue and cell lines, which corresponded with an increase in NUAK1 expression. NUAK1 was found to be a direct target of miR-145 regulation. The overexpression ofmore » miR-145 in ICC cell lines inhibited proliferation, growth, and invasion by suppressing NUAK1 expression, which was associated with a decrease in Akt signaling and matrix metalloproteinase protein expression. Similar results were observed by inhibiting NUAK1 expression. These results demonstrate that miR-145 can prevent ICC progression by targeting NUAK1 and its downstream effectors, and can therefore be useful for clinical diagnosis and targeted therapy of ICC. - Highlights: • MiR-145 suppresses ICC proliferation and invasion abilities. • We demonstrated that miR-145 directly targets NUAK1 in ICC. • MiR-145 expression in ICC was associated with Akt signaling and MMPs expression.« less
Expression and Significance of Neuroligins in Myenteric Cells of Cajal in Hirschsprung's Disease
Wang, Jian; Mou, Yaru; Zhang, Qiangye; Zhang, Fan; Yang, Hongchao; Zhang, Wentong; Li, Aiwu
2013-01-01
Purpose The aim of this study was to investigate the expression and significance of neuroligins in myenteric cells of Cajal (ICC-MY) in Hirschsprung’s disease (HSCR). Methods Longitudinal muscle with adherent myenteric plexus (LMMP) from surgical excision waste colon of HSCR children were prepared by peeling off the mucous layer, sub-mucosal layer and circular muscle. Neuroligins, c-Kit (c-Kit-immunoreactivity representing ICC) and their relationship were assessed by double labeling immunofluorescence staining. ICC-MY were dissociated and cultured from LMMP by enzymolysis method, and were purified and analyzed using a combination of magnetic-activated cell sorting (MACS) and flow cytometry (FCM). Western-blot analysis was applied to compare and evaluate the expression levels of neuroligins in ICC-MY which were dissociated from different segments of HSCR (ganglionic colonic segment, transitional colonic segment and aganglionic colonic segment). Results Neuroligins and c-Kit were expressed on the same cells (ICC-MY); ICC-MY were dissociated, cultured and purified. For HSCR, neuroligins were expressed significantly in ICC-MY from ganglionic colonic segments, moderately in those from transitional colonic segments and down-regulated significantly in those from aganglionic colonic segments. Conclusions Neuroligins were expressed in ICC-MY of human beings, and the expression varies from different segments of HSCR. This abnormal expression might play an important role in the pathogenesis of this disease through affecting the synaptic function of ICC-MY. PMID:23840625
Intercultural doctor-patient communication in daily outpatient care: relevant communication skills.
Paternotte, Emma; Scheele, Fedde; Seeleman, Conny M; Bank, Lindsay; Scherpbier, Albert J J A; van Dulmen, Sandra
2016-10-01
Intercultural communication (ICC) between doctors and patients is often associated with misunderstandings and dissatisfaction. To develop ICC-specific medical education, it is important to find out which ICC skills medical specialists currently apply in daily clinical consultations. Doctor-patient consultations of Dutch doctors with non-Dutch patients were videotaped in a multi-ethnic hospital in the Netherlands. The consultations were analyzed using the validated MAAS-Global assessment list in combination with factors influencing ICC, as described in the literature. In total, 39 videotaped consultations were analyzed. The doctors proved to be capable of practising many communication skills, such as listening and empathic communication behaviour. Other skills were not practised, such as being culturally aware and checking the patient's language ability. We showed that doctors did practice some but not all the relevant ICC skills and that the ICC style of the doctors was mainly biomedically centred. Furthermore, we discussed the possible overlap between intercultural and patient-centred communication. Implications for practice could be to implement the relevant ICC skills in the existing communication training or develop a communication training with a patient-centred approach including ICC skills.
Transcriptome of interstitial cells of Cajal reveals unique and selective gene signatures
Park, Paul J.; Fuchs, Robert; Wei, Lai; Jorgensen, Brian G.; Redelman, Doug; Ward, Sean M.; Sanders, Kenton M.
2017-01-01
Transcriptome-scale data can reveal essential clues into understanding the underlying molecular mechanisms behind specific cellular functions and biological processes. Transcriptomics is a continually growing field of research utilized in biomarker discovery. The transcriptomic profile of interstitial cells of Cajal (ICC), which serve as slow-wave electrical pacemakers for gastrointestinal (GI) smooth muscle, has yet to be uncovered. Using copGFP-labeled ICC mice and flow cytometry, we isolated ICC populations from the murine small intestine and colon and obtained their transcriptomes. In analyzing the transcriptome, we identified a unique set of ICC-restricted markers including transcription factors, epigenetic enzymes/regulators, growth factors, receptors, protein kinases/phosphatases, and ion channels/transporters. This analysis provides new and unique insights into the cellular and biological functions of ICC in GI physiology. Additionally, we constructed an interactive ICC genome browser (http://med.unr.edu/physio/transcriptome) based on the UCSC genome database. To our knowledge, this is the first online resource that provides a comprehensive library of all known genetic transcripts expressed in primary ICC. Our genome browser offers a new perspective into the alternative expression of genes in ICC and provides a valuable reference for future functional studies. PMID:28426719
Zu, Chao; Liu, Shizhang; Cao, Wei; Liu, Zongzhi; Qiang, Hui; Li, Yong; Cheng, Chong; Ji, Le; Li, Jianhui; Li, Jingyuan
2017-01-01
The functional roles and clinical significances of miR-590-3p in ICC remain unclear. In the current study, we investigated the expression of miR-590-3p in tissues and sera of ICC by real-time quantitative polymerase chain reaction. We found miR-590-3p was significantly down-regulated in the sera and tissues of ICC patients, especially in those patients with lymph node metastasis or distant metastasis. AUC curves and Cox proportional hazards mode revealed serum miR-590-3p could be novel diagnostic and prognostic biomarker for ICC patients. MiR-590-3p dramatically suppressed epithelial-mesenchymal transition, cell migration, and invasion of ICC cells. SIP1 was identified as direct and functional target of miR-590-3p in ICC cells by luciferase assays. Finally, we found SIP1 expression was inversely correlated with miR-590-3p and closely related to diminished survival in ICC patients. These findings reveal functional and mechanistic roles of miR-590-3p and EMT activator SIP1 in the pathogenesis of ICC. PMID:28423728
Monticone, Marco; Ambrosini, Emilia; Fiorentini, Roberta; Rocca, Barbara; Liquori, Valentina; Pedrocchi, Alessandra; Ferrante, Simona
2014-09-01
To evaluate the reliability and minimum detectable change (MDC) of spatial-temporal gait parameters in subjects with multiple sclerosis (MS) during dual tasking. This cross-sectional study involved 25 healthy subjects (mean age 49.9 ± 15.8 years) and 25 people with MS (mean age 49.2 ± 11.5 years). Gait under motor-cognitive and motor-motor dual tasking conditions was evaluated in two sessions separated by a one-day interval using the GAITRite Walkway System. Test-retest reliability was assessed using intraclass correlation coefficients (ICCs), standard errors of measurement (SEM), and coefficients of variation (CV). MDC scores were computed for the velocity, cadence, step and stride length, step and stride time, double support time, the % of gait cycle for single support and stance phase, and base of support. All of the gait parameters reported good to excellent ICCs under both conditions, with healthy subject values of >0.69 and MS subject values of >0.84. SEM values were always below 18% for both groups of subjects. The gait patterns of the people with MS were slightly more variable than those of the normal controls (CVs: 5.88-41.53% vs 2.84-30.48%). The assessment of quantitative gait parameters in healthy subjects and people with MS is highly reliable under both of the investigated dual tasking conditions. Copyright © 2014 Elsevier B.V. All rights reserved.
Levac, Danielle; Nawrotek, Joanna; Deschenes, Emilie; Giguere, Tia; Serafin, Julie; Bilodeau, Martin; Sveistrup, Heidi
2016-06-01
Virtual reality active video games are increasingly popular physical therapy interventions for children with cerebral palsy. However, physical therapists require educational resources to support decision making about game selection to match individual patient goals. Quantifying the movements elicited during virtual reality active video game play can inform individualized game selection in pediatric rehabilitation. The objectives of this study were to develop and evaluate the feasibility and reliability of the Movement Rating Instrument for Virtual Reality Game Play (MRI-VRGP). Item generation occurred through an iterative process of literature review and sample videotape viewing. The MRI-VRGP includes 25 items quantifying upper extremity, lower extremity, and total body movements. A total of 176 videotaped 90-second game play sessions involving 7 typically developing children and 4 children with cerebral palsy were rated by 3 raters trained in MRI-VRGP use. Children played 8 games on 2 virtual reality and active video game systems. Intraclass correlation coefficients (ICCs) determined intra-rater and interrater reliability. Excellent intrarater reliability was evidenced by ICCs of >0.75 for 17 of the 25 items across the 3 raters. Interrater reliability estimates were less precise. Excellent interrater reliability was achieved for far reach upper extremity movements (ICC=0.92 [for right and ICC=0.90 for left) and for squat (ICC=0.80) and jump items (ICC=0.99), with 9 items achieving ICCs of >0.70, 12 items achieving ICCs of between 0.40 and 0.70, and 4 items achieving poor reliability (close-reach upper extremity-ICC=0.14 for right and ICC=0.07 for left) and single-leg stance (ICC=0.55 for right and ICC=0.27 for left). Poor video quality, differing item interpretations between raters, and difficulty quantifying the high-speed movements involved in game play affected reliability. With item definition clarification and further psychometric property evaluation, the MRI-VRGP could inform the content of educational resources for therapists by ranking games according to frequency and type of elicited body movements.
Nawrotek, Joanna; Deschenes, Emilie; Giguere, Tia; Serafin, Julie; Bilodeau, Martin; Sveistrup, Heidi
2016-01-01
Background Virtual reality active video games are increasingly popular physical therapy interventions for children with cerebral palsy. However, physical therapists require educational resources to support decision making about game selection to match individual patient goals. Quantifying the movements elicited during virtual reality active video game play can inform individualized game selection in pediatric rehabilitation. Objective The objectives of this study were to develop and evaluate the feasibility and reliability of the Movement Rating Instrument for Virtual Reality Game Play (MRI-VRGP). Methods Item generation occurred through an iterative process of literature review and sample videotape viewing. The MRI-VRGP includes 25 items quantifying upper extremity, lower extremity, and total body movements. A total of 176 videotaped 90-second game play sessions involving 7 typically developing children and 4 children with cerebral palsy were rated by 3 raters trained in MRI-VRGP use. Children played 8 games on 2 virtual reality and active video game systems. Intraclass correlation coefficients (ICCs) determined intra-rater and interrater reliability. Results Excellent intrarater reliability was evidenced by ICCs of >0.75 for 17 of the 25 items across the 3 raters. Interrater reliability estimates were less precise. Excellent interrater reliability was achieved for far reach upper extremity movements (ICC=0.92 [for right and ICC=0.90 for left) and for squat (ICC=0.80) and jump items (ICC=0.99), with 9 items achieving ICCs of >0.70, 12 items achieving ICCs of between 0.40 and 0.70, and 4 items achieving poor reliability (close-reach upper extremity-ICC=0.14 for right and ICC=0.07 for left) and single-leg stance (ICC=0.55 for right and ICC=0.27 for left). Conclusions Poor video quality, differing item interpretations between raters, and difficulty quantifying the high-speed movements involved in game play affected reliability. With item definition clarification and further psychometric property evaluation, the MRI-VRGP could inform the content of educational resources for therapists by ranking games according to frequency and type of elicited body movements. PMID:27251029
Forward-looking automotive radar sensor
NASA Astrophysics Data System (ADS)
Ganci, Paul; Potts, Steven; Okurowski, Frank
1995-12-01
For intelligent cruise control (ICC) and forward looking collision warning systems to be successful products they must provide robust performance in a complex roadway environment. Inconveniences caused by dropped tracks and nuisance alarms will not be tolerated by consumers, and would likely result in rejection of these new technologies in the marketplace. The authors report on a low-cost automotive millimeter wave (MMW) radar design which addresses shortcomings associated with previously reported ICC system implementations. The importance of the sensor's ability to identify and separately track all obstacles in the field of view is discussed. The applicability of the MMW's FM-CW sensor implementation to collision warning systems is also discussed.
Hsu, Hsien-Yuan; Lin, Jr-Hung; Kwok, Oi-Man; Acosta, Sandra; Willson, Victor
2016-01-01
Several researchers have recommended that level-specific fit indices should be applied to detect the lack of model fit at any level in multilevel structural equation models. Although we concur with their view, we note that these studies did not sufficiently consider the impact of intraclass correlation (ICC) on the performance of level-specific fit indices. Our study proposed to fill this gap in the methodological literature. A Monte Carlo study was conducted to investigate the performance of (a) level-specific fit indices derived by a partially saturated model method (e.g., CFIPS_B and CFIPS_W) and (b) SRMRW and SRMRB in terms of their performance in multilevel structural equation models across varying ICCs. The design factors included intraclass correlation (ICC: ICC1 = 0.091 to ICC6 = 0.500), numbers of groups in between-level models (NG: 50, 100, 200, and 1,000), group size (GS: 30, 50, and 100), and type of misspecification (no misspecification, between-level misspecification, and within-level misspecification). Our simulation findings raise a concern regarding the performance of between-level-specific partial saturated fit indices in low ICC conditions: the performances of both TLIPS_B and RMSEAPS_B were more influenced by ICC compared with CFIPS_B and SRMRB. However, when traditional cutoff values (RMSEA≤ 0.06; CFI, TLI≥ 0.95; SRMR≤ 0.08) were applied, CFIPS_B and TLIPS_B were still able to detect misspecified between-level models even when ICC was as low as 0.091 (ICC1). On the other hand, both RMSEAPS_B and SRMRB were not recommended under low ICC conditions. PMID:29795901
Hashitani, Hikaru; Suzuki, Hikaru
2007-01-01
Interstitial cells of Cajal-like cells (ICC-LCs) in the urethra may act as electrical pacemakers of spontaneous contractions. However, their properties in situ and their interaction with neighbouring urethral smooth muscle cells (USMCs) remain to be elucidated. To further explore the physiological role of ICC-LCs, spontaneous changes in [Ca2+]i (Ca2+ transients) were visualized in fluo-4 loaded preparations of rabbit urethral smooth muscle. ICC-LCs were sparsely distributed, rather than forming an extensive network. Ca2+ transients in ICC-LCs had a lower frequency and a longer half-width than those of USMCs. ICC-LCs often exhibited Ca2+ transients synchronously with each other, but did not often show a close temporal relationship with Ca2+ transients in USMCs. Nicardipine (1 μm) suppressed Ca2+ transients in USMCs but not in ICC-LCs. Ca2+ transients in ICC-LCs were abolished by cyclopiazonic acid (10 μm), ryanodine (50 μm) and caffeine (10 mm) or by removing extracellular Ca2+, and inhibited by 2-aminoethoxydiphenyl borate (50 μm) and 3-morpholino-sydnonimine (SIN-1; 10 μm), but facilitated by increasing extracellular Ca2+ or phenylephrine (1–10 μm). These results indicated that Ca2+ transients in urethral ICC-LCs in situ rely on both Ca2+ release from intracellular Ca2+ stores and Ca2+ influx through non-L-type Ca2+ channel pathways. ICC-LCs may not act as a coordinated pacemaker electrical network as do ICC in the gastrointestinal (GI) tract. Rather they may randomly increase excitability of USMCs to maintain the tone of urethral smooth muscles. PMID:17615099
Adherence to ICCS nomenclature guidelines in subsequent literature: a bibliometric study.
Dannaway, Jasan; Ng, Heryanto; Deshpande, Aniruddh V
2013-09-01
Since the publication of the 2006 International Children's Continence Society (ICCS) guidelines on terminologies for lower urinary tract dysfunction in children, little is known of their impact. In this study, we aim to quantify the adherence to the guidelines in the published literature, and to examine whether Medical Subject Headings (MeSH) in MEDLINE reflect the recommended "new" ICCS terminology. Seven pairs of pre-specified paired terms (obsolete and recommended by the ICCS) were searched, limited to paediatric literature published between 2002 and 2010. Their use in the literature was compared between the pre-guideline (2002-2005) and post-guideline (2007-2010) period and across geographical regions. MeSH in MEDLINE were examined for the use of ICCS preferred terminology. Publications in paediatric urinary incontinence have shown a 49% increase from 2002-2005 to 2007-2010 (55-82 per year). There was about a fourfold increase in the likelihood of usage of ICCS recommended terminologies post ICCS guideline publication (OR: 4.19, 95% CI: 3.04-5.78, P < 0.001). Approximately 25% of the studies published between 2007 and 2010 used obsolete terminologies. Analysis indicated satisfactory uptake for most terms, with the exception of "urotherapy." There was no significant geographical variation in uptake. More than half of the ICCS-recommended terms (4/7) did not appear in the current MeSH indexing tree and scope notes. Overall uptake of recommended terms following release of ICCS terminology guidelines was encouraging although it remains suboptimal for certain terms. Efforts need to be made to improve the current MEDLINE indexing so that MeSH terms reflect terminology recommended by the ICCS. Copyright © 2012 Wiley Periodicals, Inc.
Hade, Erinn M; Murray, David M; Pennell, Michael L; Rhoda, Dale; Paskett, Electra D; Champion, Victoria L; Crabtree, Benjamin F; Dietrich, Allen; Dignan, Mark B; Farmer, Melissa; Fenton, Joshua J; Flocke, Susan; Hiatt, Robert A; Hudson, Shawna V; Mitchell, Michael; Monahan, Patrick; Shariff-Marco, Salma; Slone, Stacey L; Stange, Kurt; Stewart, Susan L; Strickland, Pamela A Ohman
2010-01-01
Screening has become one of our best tools for early detection and prevention of cancer. The group-randomized trial is the most rigorous experimental design for evaluating multilevel interventions. However, identifying the proper sample size for a group-randomized trial requires reliable estimates of intraclass correlation (ICC) for screening outcomes, which are not available to researchers. We present crude and adjusted ICC estimates for cancer screening outcomes for various levels of aggregation (physician, clinic, and county) and provide an example of how these ICC estimates may be used in the design of a future trial. Investigators working in the area of cancer screening were contacted and asked to provide crude and adjusted ICC estimates using the analysis of variance method estimator. Of the 29 investigators identified, estimates were obtained from 10 investigators who had relevant data. ICC estimates were calculated from 13 different studies, with more than half of the studies collecting information on colorectal screening. In the majority of cases, ICC estimates could be adjusted for age, education, and other demographic characteristics, leading to a reduction in the ICC. ICC estimates varied considerably by cancer site and level of aggregation of the groups. Previously, only two articles had published ICCs for cancer screening outcomes. We have complied more than 130 crude and adjusted ICC estimates covering breast, cervical, colon, and prostate screening and have detailed them by level of aggregation, screening measure, and study characteristics. We have also demonstrated their use in planning a future trial and the need for the evaluation of the proposed interval estimator for binary outcomes under conditions typically seen in GRTs.
Reliability of heart rate measures during walking before and after running maximal efforts.
Boullosa, D A; Barros, E S; del Rosso, S; Nakamura, F Y; Leicht, A S
2014-11-01
Previous studies on HR recovery (HRR) measures have utilized the supine and the seated postures. However, the most common recovery mode in sport and clinical settings after running exercise is active walking. The aim of the current study was to examine the reliability of HR measures during walking (4 km · h(-1)) before and following a maximal test. Twelve endurance athletes performed an incremental running test on 2 days separated by 48 h. Absolute (coefficient of variation, CV, %) and relative [Intraclass correlation coefficient, (ICC)] reliability of time domain and non-linear measures of HR variability (HRV) from 3 min recordings, and HRR parameters over 5 min were assessed. Moderate to very high reliability was identified for most HRV indices with short-term components of time domain and non-linear HRV measures demonstrating the greatest reliability before (CV: 12-22%; ICC: 0.73-0.92) and after exercise (CV: 14-32%; ICC: 0.78-0.91). Most HRR indices and parameters of HRR kinetics demonstrated high to very high reliability with HR values at a given point and the asymptotic value of HR being the most reliable (CV: 2.5-10.6%; ICC: 0.81-0.97). These findings demonstrate these measures as reliable tools for the assessment of autonomic control of HR during walking before and after maximal efforts. © Georg Thieme Verlag KG Stuttgart · New York.
Egan, Kaitlyn N; Cohen, L Adelyn; Limbers, Christine
2018-03-06
Despite its widespread use, a minimal amount is known regarding the agreement between parent and youth ratings of youth's executive functioning on the Behavior Rating Inventory of Executive Functioning (BRIEF) in typically developing youth. The present study examined parent-child agreement on the BRIEF with a community sample of adolescents and their parents. Ninety-seven parent-child dyads (M age = 13.91 years; SD = .52) completed the BRIEF self- and parent-report forms and a demographic questionnaire. Intraclass Correlation Coefficients (ICCs) and paired sample t-tests were used to evaluate agreement between self- and parent-reports on the BRIEF. Total sample ICCs indicated moderate to good parent-child agreement (0.46-0.68). Parents from the total sample reported significantly higher mean T-scores for their adolescents on Inhibit, Working Memory, Planning/Organization, Behavioral Regulation Index (BRI), Metacognition Index, and Global Executive Composite. Differences were found in regard to gender and race/ethnicity: ICCs were higher between parent-girl dyads on the scales that comprise the BRI than between parent-boy dyads. Parent-adolescent ICCs were also higher for adolescents who self-identified as White in comparison to those who identified as Non-White/Mixed Race on Emotional Control. These findings suggest gender and racial/ethnic differences should be considered when examining parent-child agreement on the BRIEF in typically developing adolescents.
Development of a computational technique to measure cartilage contact area.
Willing, Ryan; Lapner, Michael; Lalone, Emily A; King, Graham J W; Johnson, James A
2014-03-21
Computational measurement of joint contact distributions offers the benefit of non-invasive measurements of joint contact without the use of interpositional sensors or casting materials. This paper describes a technique for indirectly measuring joint contact based on overlapping of articular cartilage computer models derived from CT images and positioned using in vitro motion capture data. The accuracy of this technique when using the physiological nonuniform cartilage thickness distribution, or simplified uniform cartilage thickness distributions, is quantified through comparison with direct measurements of contact area made using a casting technique. The efficacy of using indirect contact measurement techniques for measuring the changes in contact area resulting from hemiarthroplasty at the elbow is also quantified. Using the physiological nonuniform cartilage thickness distribution reliably measured contact area (ICC=0.727), but not better than the assumed bone specific uniform cartilage thicknesses (ICC=0.673). When a contact pattern agreement score (s(agree)) was used to assess the accuracy of cartilage contact measurements made using physiological nonuniform or simplified uniform cartilage thickness distributions in terms of size, shape and location, their accuracies were not significantly different (p>0.05). The results of this study demonstrate that cartilage contact can be measured indirectly based on the overlapping of cartilage contact models. However, the results also suggest that in some situations, inter-bone distance measurement and an assumed cartilage thickness may suffice for predicting joint contact patterns. Copyright © 2014 Elsevier Ltd. All rights reserved.
DOT National Transportation Integrated Search
1998-07-01
This report is one element of a cooperative agreement between NHTSA and UMTRI entitled Intelligent Cruise Control (ICC) Field Operational Test (FOT). It addresses the operation of a serial string or dense cluster of passenger cars equipped with a new...
Fully automatic segmentation of white matter hyperintensities in MR images of the elderly.
Admiraal-Behloul, F; van den Heuvel, D M J; Olofsen, H; van Osch, M J P; van der Grond, J; van Buchem, M A; Reiber, J H C
2005-11-15
The role of quantitative image analysis in large clinical trials is continuously increasing. Several methods are available for performing white matter hyperintensity (WMH) volume quantification. They vary in the amount of the human interaction involved. In this paper, we describe a fully automatic segmentation that was used to quantify WMHs in a large clinical trial on elderly subjects. Our segmentation method combines information from 3 different MR images: proton density (PD), T2-weighted and fluid-attenuated inversion recovery (FLAIR) images; our method uses an established artificial intelligent technique (fuzzy inference system) and does not require extensive computations. The reproducibility of the segmentation was evaluated in 9 patients who underwent scan-rescan with repositioning; an inter-class correlation coefficient (ICC) of 0.91 was obtained. The effect of differences in image resolution was tested in 44 patients, scanned with 6- and 3-mm slice thickness FLAIR images; we obtained an ICC value of 0.99. The accuracy of the segmentation was evaluated on 100 patients for whom manual delineation of WMHs was available; the obtained ICC was 0.98 and the similarity index was 0.75. Besides the fact that the approach demonstrated very high volumetric and spatial agreement with expert delineation, the software did not require more than 2 min per patient (from loading the images to saving the results) on a Pentium-4 processor (512 MB RAM).
Erle, F.; Ceylan, F.; Erdemir, T.; Toker, C.
2009-01-01
The chickpea, Cicer arietinum L. (Fabales: Fabaceae), seeds are vulnerable, both in the field and in storage, to attack by seed-beetles. Beetles of the genus Callosobruchus are major storage pests of chickpea crops and cause considerable economic losses. In the present study, a total of 11 chickpea genotypes including five ‘kabuli’ (Mexican white, Diyar, CA 2969, ILC 8617 and ACC 245) and six ‘desi’ chickpeas (ICC 1069, ICC 12422, ICC 14336, ICC 4957, ICC 4969 and ICC 7509) were evaluated for resistance to the pulse beetle Callosobruchus maculatus F. (Coleoptera: Bruchidae). Resistance was evaluated by measuring percent damage to seeds. Damage to seeds by C. maculatus was manifested by the round exit holes with the ‘flap’ of seed coat made by emerging adults. Of the 11 genotypes tested, only one (ICC 4969) exhibited a complete resistance to C. maculatus in both free-choice and no-choice tests; no seed damage was found over the test period. In general, the ‘desi’ chickpeas were more resistant to C. maculatus than the ‘kabuli’ chickpeas. Among the tested chickpea genotypes, only ICC 4969 can be used as a source of C. maculatus resistance in breeding programmes that could then be grown in organic cultivation free from pesticides. PMID:20050777
Erle, F; Ceylan, F; Erdemir, T; Toker, C
2009-01-01
Abstract The chickpea, Cicer arietinum L. (Fabales: Fabaceae), seeds are vulnerable, both in the field and in storage, to attack by seed-beetles. Beetles of the genus Callosobruchus are major storage pests of chickpea crops and cause considerable economic losses. In the present study, a total of 11 chickpea genotypes including five 'kabuli' (Mexican white, Diyar, CA 2969, ILC 8617 and ACC 245) and six 'desi' chickpeas (ICC 1069, ICC 12422, ICC 14336, ICC 4957, ICC 4969 and ICC 7509) were evaluated for resistance to the pulse beetle Callosobruchus maculatus F. (Coleoptera: Bruchidae). Resistance was evaluated by measuring percent damage to seeds. Damage to seeds by C. maculatus was manifested by the round exit holes with the 'flap' of seed coat made by emerging adults. Of the 11 genotypes tested, only one (ICC 4969) exhibited a complete resistance to C. maculatus in both free-choice and no-choice tests; no seed damage was found over the test period. In general, the 'desi' chickpeas were more resistant to C. maculatus than the 'kabuli' chickpeas. Among the tested chickpea genotypes, only ICC 4969 can be used as a source of C. maculatus resistance in breeding programmes that could then be grown in organic cultivation free from pesticides.
Kalia, Sumeet; Klar, Neil; Donner, Allan
2016-12-30
Cluster randomized trials (CRTs) involve the random assignment of intact social units rather than independent subjects to intervention groups. Time-to-event outcomes often are endpoints in CRTs. Analyses of such data need to account for the correlation among cluster members. The intracluster correlation coefficient (ICC) is used to assess the similarity among binary and continuous outcomes that belong to the same cluster. However, estimating the ICC in CRTs with time-to-event outcomes is a challenge because of the presence of censored observations. The literature suggests that the ICC may be estimated using either censoring indicators or observed event times. A simulation study explores the effect of administrative censoring on estimating the ICC. Results show that ICC estimators derived from censoring indicators or observed event times are negatively biased. Analytic work further supports these results. Observed event times are preferred to estimate the ICC under minimum frequency of administrative censoring. To our knowledge, the existing literature provides no practical guidance on the estimation of ICC when substantial amount of administrative censoring is present. The results from this study corroborate the need for further methodological research on estimating the ICC for correlated time-to-event outcomes. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Twelve tips for delivering successful interprofessional case conferences.
O'Brien, Bridget C; Patel, Shalini R; Pearson, Meg; Eastburn, Abigail P; Earnest, Gillian E; Strewler, Anna; Gager, Krista; Manuel, Jennifer K; Dulay, Maya; Bachhuber, Melissa R; Shunk, Rebecca
2017-12-01
Interprofessional case conferences (ICCs) offer an interactive, practical way to engage members of two or more health professions in discussions that involve learning and working together to improve patient care. Well-orchestrated ICCs provide opportunities to integrate interprofessional (IP) education into routine clinical practice. The authors provide 12 tips to support the conceptualization, planning, implementation, facilitation, evaluation, and sustainability of ICCs. They draw from extensive experience as IP educators and facilitators of ICCs and from literature on IP education, case-based learning, small-group facilitation, peer-assisted learning, and learner engagement - all of which offer insights into ICCs but have not been integrated and applied to this context.
ICC 700-2012: 2012 National Green Building Standard (ICC 700)
Description of the ICC 700-2012: 2012 National Green Building Standard, a rating and certification system that aims to encourage increased environmental and health performance in residences and residential portions of buildings.
Hybrid Robust Multi-Objective Evolutionary Optimization Algorithm
2009-03-10
pp. 594-606. 8. Inverse Approaches to Drying of Thin Bodies With Significant Shrinkage Effects (with G. H. Kanevce, L. P. Kanevce, V. B. Mitrevski ...Kanevce, L. Kanevce, V. Mitrevski ), ICCES: International Conference on Computational & Experimental Engineering and Sciences, Honolulu, Hawaii, March 17...Miami Beach, FL, April 16-18, 2007. 16. Inverse Approaches to Drying of Sliced Foods (with Kanevce, G. H., Kanevce, Lj. P., and Mitrevski , V. B
Suojärvi, Nora; Sillat, T; Lindfors, N; Koskinen, S K
2015-12-01
Operative treatment of an intra-articular distal radius fracture is one of the most common procedures in orthopedic and hand surgery. The intra- and interobserver agreement of common radiographical measurements of these fractures using cone beam computed tomography (CBCT) and plain radiographs were evaluated. Thirty-seven patients undergoing open reduction and volar fixation for a distal radius fracture were studied. Two radiologists analyzed the preoperative radiographs and CBCT images. Agreement of the measurements was subjected to intra-class correlation coefficient and the Bland-Altman analyses. Plain radiographs provided a slightly poorer level of agreement. For fracture diastasis, excellent intraobserver agreement was achieved for radiographs and good or excellent agreement for CBCT, compared to poor interobserver agreement (ICC 0.334) for radiographs and good interobserver agreement (ICC 0.621) for CBCT images. The Bland-Altman analyses indicated a small mean difference between the measurements but rather large variation using both imaging methods, especially in angular measurements. For most of the measurements, radiographs do well, and may be used in clinical practice. Two different measurements by the same reader or by two different readers can lead to different decisions, and therefore a standardization of the measurements is imperative. More detailed analysis of articular surface needs cross-sectional imaging modalities.
Validity of Computer Adaptive Tests of Daily Routines for Youth with Spinal Cord Injury
Haley, Stephen M.
2013-01-01
Objective: To evaluate the accuracy of computer adaptive tests (CATs) of daily routines for child- and parent-reported outcomes following pediatric spinal cord injury (SCI) and to evaluate the validity of the scales. Methods: One hundred ninety-six daily routine items were administered to 381 youths and 322 parents. Pearson correlations, intraclass correlation coefficients (ICC), and 95% confidence intervals (CI) were calculated to evaluate the accuracy of simulated 5-item, 10-item, and 15-item CATs against the full-item banks and to evaluate concurrent validity. Independent samples t tests and analysis of variance were used to evaluate the ability of the daily routine scales to discriminate between children with tetraplegia and paraplegia and among 5 motor groups. Results: ICC and 95% CI demonstrated that simulated 5-, 10-, and 15-item CATs accurately represented the full-item banks for both child- and parent-report scales. The daily routine scales demonstrated discriminative validity, except between 2 motor groups of children with paraplegia. Concurrent validity of the daily routine scales was demonstrated through significant relationships with the FIM scores. Conclusion: Child- and parent-reported outcomes of daily routines can be obtained using CATs with the same relative precision of a full-item bank. Five-item, 10-item, and 15-item CATs have discriminative and concurrent validity. PMID:23671380
Anderson, Donald D; Segal, Neil A; Kern, Andrew M; Nevitt, Michael C; Torner, James C; Lynch, John A
2012-01-01
Recent findings suggest that contact stress is a potent predictor of subsequent symptomatic osteoarthritis development in the knee. However, much larger numbers of knees (likely on the order of hundreds, if not thousands) need to be reliably analyzed to achieve the statistical power necessary to clarify this relationship. This study assessed the reliability of new semiautomated computational methods for estimating contact stress in knees from large population-based cohorts. Ten knees of subjects from the Multicenter Osteoarthritis Study were included. Bone surfaces were manually segmented from sequential 1.0 Tesla magnetic resonance imaging slices by three individuals on two nonconsecutive days. Four individuals then registered the resulting bone surfaces to corresponding bone edges on weight-bearing radiographs, using a semi-automated algorithm. Discrete element analysis methods were used to estimate contact stress distributions for each knee. Segmentation and registration reliabilities (day-to-day and interrater) for peak and mean medial and lateral tibiofemoral contact stress were assessed with Shrout-Fleiss intraclass correlation coefficients (ICCs). The segmentation and registration steps of the modeling approach were found to have excellent day-to-day (ICC 0.93-0.99) and good inter-rater reliability (0.84-0.97). This approach for estimating compartment-specific tibiofemoral contact stress appears to be sufficiently reliable for use in large population-based cohorts.
Reproducibility of airway luminal size in asthma measured by HRCT.
Brown, Robert H; Henderson, Robert J; Sugar, Elizabeth A; Holbrook, Janet T; Wise, Robert A
2017-10-01
Brown RH, Henderson RJ, Sugar EA, Holbrook JT, Wise RA, on behalf of the American Lung Association Airways Clinical Research Centers. Reproducibility of airway luminal size in asthma measured by HRCT. J Appl Physiol 123: 876-883, 2017. First published July 13, 2017; doi:10.1152/japplphysiol.00307.2017.-High-resolution CT (HRCT) is a well-established imaging technology used to measure lung and airway morphology in vivo. However, there is a surprising lack of studies examining HRCT reproducibility. The CPAP Trial was a multicenter, randomized, three-parallel-arm, sham-controlled 12-wk clinical trial to assess the use of a nocturnal continuous positive airway pressure (CPAP) device on airway reactivity to methacholine. The lack of a treatment effect of CPAP on clinical or HRCT measures provided an opportunity for the current analysis. We assessed the reproducibility of HRCT imaging over 12 wk. Intraclass correlation coefficients (ICCs) were calculated for individual airway segments, individual lung lobes, both lungs, and air trapping. The ICC [95% confidence interval (CI)] for airway luminal size at total lung capacity ranged from 0.95 (0.91, 0.97) to 0.47 (0.27, 0.69). The ICC (95% CI) for airway luminal size at functional residual capacity ranged from 0.91 (0.85, 0.95) to 0.32 (0.11, 0.65). The ICC measurements for airway distensibility index and wall thickness were lower, ranging from poor (0.08) to moderate (0.63) agreement. The ICC for air trapping at functional residual capacity was 0.89 (0.81, 0.94) and varied only modestly by lobe from 0.76 (0.61, 0.87) to 0.95 (0.92, 0.97). In stable well-controlled asthmatic subjects, it is possible to reproducibly image unstimulated airway luminal areas over time, by region, and by size at total lung capacity throughout the lungs. Therefore, any changes in luminal size on repeat CT imaging are more likely due to changes in disease state and less likely due to normal variability. NEW & NOTEWORTHY There is a surprising lack of studies examining the reproducibility of high-resolution CT in asthma. The current study examined reproducibility of airway measurements. In stable well-controlled asthmatic subjects, it is possible to reproducibly image airway luminal areas over time, by region, and by size at total lung capacity throughout the lungs. Therefore, any changes in luminal size on repeat CT imaging are more likely due to changes in disease state and less likely due to normal variability. Copyright © 2017 the American Physiological Society.
Oremus, Carolina; Hall, Geoffrey B C; McKinnon, Margaret C
2012-01-01
Introduction Quality assessment of included studies is an important component of systematic reviews. Objective The authors investigated inter-rater and test–retest reliability for quality assessments conducted by inexperienced student raters. Design Student raters received a training session on quality assessment using the Jadad Scale for randomised controlled trials and the Newcastle–Ottawa Scale (NOS) for observational studies. Raters were randomly assigned into five pairs and they each independently rated the quality of 13–20 articles. These articles were drawn from a pool of 78 papers examining cognitive impairment following electroconvulsive therapy to treat major depressive disorder. The articles were randomly distributed to the raters. Two months later, each rater re-assessed the quality of half of their assigned articles. Setting McMaster Integrative Neuroscience Discovery and Study Program. Participants 10 students taking McMaster Integrative Neuroscience Discovery and Study Program courses. Main outcome measures The authors measured inter-rater reliability using κ and the intraclass correlation coefficient type 2,1 or ICC(2,1). The authors measured test–retest reliability using ICC(2,1). Results Inter-rater reliability varied by scale question. For the six-item Jadad Scale, question-specific κs ranged from 0.13 (95% CI −0.11 to 0.37) to 0.56 (95% CI 0.29 to 0.83). The ranges were −0.14 (95% CI −0.28 to 0.00) to 0.39 (95% CI −0.02 to 0.81) for the NOS cohort and −0.20 (95% CI −0.49 to 0.09) to 1.00 (95% CI 1.00 to 1.00) for the NOS case–control. For overall scores on the six-item Jadad Scale, ICC(2,1)s for inter-rater and test–retest reliability (accounting for systematic differences between raters) were 0.32 (95% CI 0.08 to 0.52) and 0.55 (95% CI 0.41 to 0.67), respectively. Corresponding ICC(2,1)s for the NOS cohort were −0.19 (95% CI −0.67 to 0.35) and 0.62 (95% CI 0.25 to 0.83), and for the NOS case–control, the ICC(2,1)s were 0.46 (95% CI −0.13 to 0.92) and 0.83 (95% CI 0.48 to 0.95). Conclusions Inter-rater reliability was generally poor to fair and test–retest reliability was fair to excellent. A pilot rating phase following rater training may be one way to improve agreement. PMID:22855629
Oremus, Mark; Oremus, Carolina; Hall, Geoffrey B C; McKinnon, Margaret C
2012-01-01
Quality assessment of included studies is an important component of systematic reviews. The authors investigated inter-rater and test-retest reliability for quality assessments conducted by inexperienced student raters. Student raters received a training session on quality assessment using the Jadad Scale for randomised controlled trials and the Newcastle-Ottawa Scale (NOS) for observational studies. Raters were randomly assigned into five pairs and they each independently rated the quality of 13-20 articles. These articles were drawn from a pool of 78 papers examining cognitive impairment following electroconvulsive therapy to treat major depressive disorder. The articles were randomly distributed to the raters. Two months later, each rater re-assessed the quality of half of their assigned articles. McMaster Integrative Neuroscience Discovery and Study Program. 10 students taking McMaster Integrative Neuroscience Discovery and Study Program courses. The authors measured inter-rater reliability using κ and the intraclass correlation coefficient type 2,1 or ICC(2,1). The authors measured test-retest reliability using ICC(2,1). Inter-rater reliability varied by scale question. For the six-item Jadad Scale, question-specific κs ranged from 0.13 (95% CI -0.11 to 0.37) to 0.56 (95% CI 0.29 to 0.83). The ranges were -0.14 (95% CI -0.28 to 0.00) to 0.39 (95% CI -0.02 to 0.81) for the NOS cohort and -0.20 (95% CI -0.49 to 0.09) to 1.00 (95% CI 1.00 to 1.00) for the NOS case-control. For overall scores on the six-item Jadad Scale, ICC(2,1)s for inter-rater and test-retest reliability (accounting for systematic differences between raters) were 0.32 (95% CI 0.08 to 0.52) and 0.55 (95% CI 0.41 to 0.67), respectively. Corresponding ICC(2,1)s for the NOS cohort were -0.19 (95% CI -0.67 to 0.35) and 0.62 (95% CI 0.25 to 0.83), and for the NOS case-control, the ICC(2,1)s were 0.46 (95% CI -0.13 to 0.92) and 0.83 (95% CI 0.48 to 0.95). Inter-rater reliability was generally poor to fair and test-retest reliability was fair to excellent. A pilot rating phase following rater training may be one way to improve agreement.
Armstrong, Anderson C.; Ricketts, Erin P.; Cox, Christopher; Adler, Paul; Arynchyn, Alexander; Liu, Kiang; Stengel, Ellen; RDCS; Sidney, Stephen; Lewis, Cora E.; Schreiner, Pamela J.; Shikany, James M.; Keck, Kimberly; Merlo, Jamie; Gidding, Samuel S.; Lima, João A. C.
2014-01-01
Introduction Few large studies describe quality control procedures and reproducibility findings in cardiovascular ultra-sound, particularly in novel techniques such as Speckle Tracking (STE). We evaluate the echocardiography assessment performance in the CARDIA study Y25 examination (2010-2011) and report findings from a quality control and reproducibility program conducted to assess Field Center image acquisition and Reading Center (RC) accuracy. Methods The CARDIA Y25 examination had 3,475 echocardiograms performed in 4 US Field Centers and analyzed in a Reading Center, assessing standard echocardiography (LA dimension, aortic root, LV mass, LV end-diastolic volume [LVEDV], ejection fraction [LVEF]), and STE (2- and 4-chamber longitudinal, circumferential, and radial strains). Reproducibility was assessed using intra-class correlation coefficients (ICC), coefficients of variation (CV), and Bland-Altman plots. Results For standard echocardiography reproducibility, LV mass and LVEDV consistently had CV above 10% and aortic root below 6%. Intra-sonographer aortic root and LV mass had the most robust values of ICC in standard echocardiography. For STE, the number of properly tracking segments was above 80% in short-axis and 4-chamber and 58% in 2-chamber. Longitudinal strain parameters were the most robust and radial strain showed the highest variation. Comparing Field Centers with Echo RC STE readings, mean differences ranged from 0.4% to 4.1% and ICC from 0.37 to 0.66, with robust results for longitudinal strains. Conclusion Echocardiography image acquisition and reading processes in the CARDIA study were highly reproducible, including robust results for STE analysis. Consistent quality control may increase the reliability of echocardiography measurements in large cohort studies. PMID:25382818
Armstrong, Anderson C; Ricketts, Erin P; Cox, Christopher; Adler, Paul; Arynchyn, Alexander; Liu, Kiang; Stengel, Ellen; Sidney, Stephen; Lewis, Cora E; Schreiner, Pamela J; Shikany, James M; Keck, Kimberly; Merlo, Jamie; Gidding, Samuel S; Lima, João A C
2015-08-01
Few large studies describe quality control procedures and reproducibility findings in cardiovascular ultrasound, particularly in novel techniques such as speckle tracking echocardiography (STE). We evaluate the echocardiography assessment performance in the Coronary Artery Risk Development in Young Adults (CARDIA) study Year 25 (Y25) examination (2010-2011) and report findings from a quality control and reproducibility program conducted to assess Field Center image acquisition and reading center (RC) accuracy. The CARDIA Y25 examination had 3475 echocardiograms performed in 4 US Field Centers and analyzed in a RC, assessing standard echocardiography (LA dimension, aortic root, LV mass, LV end-diastolic volume [LVEDV], ejection fraction [LVEF]), and STE (two- and four-chamber longitudinal, circumferential, and radial strains). Reproducibility was assessed using intraclass correlation coefficients (ICC), coefficients of variation (CV), and Bland-Altman plots. For standard echocardiography reproducibility, LV mass and LVEDV consistently had CV above 10% and aortic root below 6%. Intra-sonographer aortic root and LV mass had the most robust values of ICC in standard echocardiography. For STE, the number of properly tracking segments was above 80% in short-axis and four-chamber and 58% in two-chamber views. Longitudinal strain parameters were the most robust and radial strain showed the highest variation. Comparing Field Centers with echocardiography RC STE readings, mean differences ranged from 0.4% to 4.1% and ICC from 0.37 to 0.66, with robust results for longitudinal strains. Echocardiography image acquisition and reading processes in the CARDIA study were highly reproducible, including robust results for STE analysis. Consistent quality control may increase the reliability of echocardiography measurements in large cohort studies. © 2014, Wiley Periodicals, Inc.
The profile and familiality of personality traits in mood disorder families.
Wu, Pei-Jung; Chang, Sheng-Mao; Lu, Ming-Kun; Chen, Wei J; Yang, Yen-Kuang; Yeh, Tzung-Lieh; Liao, Shin-Cheng; Lu, Ru-Band; Kuo, Po-Hsiu
2012-05-01
Personality traits have impacts on individuals' response to stress and mood expression. The current study aimed to investigate the profile of personality traits in patients with bipolar disorders and major depressive disorder (MDD). Familial aggregation of personality traits in mood disorder families was also evaluated. We recruited 260 clinical patients of MDD (92), bipolar disorder-I and II (BP-I=111, BP-II=57), 190 first-degree relatives, and 180 controls. Four personality traits were assessed using the Eysenck and Tridimensional Personality Questionnaires, including Extraversion (E), Neuroticism (N), Harm Avoidance (HA), and Novelty Seeking (NS). The magnitude of familiality of personality traits in mood disorder families was evaluated by mixed models and intra-class correlation coefficients (ICC). Patients with mood disorders had lower E, and higher N, HA and NS than controls. Unaffected relatives were not differed from controls in the four personality traits. BP-I had higher E, NS and lower N, HA than MDD patients (p<0.01). The scale N further distinguished BP-I from BP-II (p=0.02) with lower N among BP-I patients. There exhibited moderate familiality in E (ICC=0.184-0.239) and HA (ICC=0.355) in bipolar disorder families. Personality traits were accessed cross-sectionally without quantitatively controlled severity of mood symptoms. Different patterns of personality traits distinguish patients from unaffected individuals as well as separate diagnoses of mood disorders, indicating the usage of more comprehensive evaluation of personality traits in clinical settings. Familiality of extraversion and harm avoidance in bipolar disorder families provides insights for further investigating correlates of comorbid behavioral problems in bipolar disorders. Copyright © 2012 Elsevier B.V. All rights reserved.
Yoshino, A; Shigemura, J; Kobayashi, Y; Nomura, S; Shishikura, K; Den, R; Wakisaka, H; Kamata, S; Ashida, H
2001-09-01
We assessed the reliability of remote video psychiatric interviews conducted via the internet using narrow and broad bandwidths. Televideo psychiatric interviews conducted with 42 in-patients with chronic schizophrenia using two bandwidths (narrow, 128 kilobits/s; broad, 2 megabits/s) were assessed in terms of agreement with face-to-face interviews in a test-retest fashion. As a control, agreement was assessed between face-to-face interviews. Psychiatric symptoms were rated using the Oxford version of the Brief Psychiatric Rating Scale (BPRS), and agreement between interviews was estimated as the intraclass correlation coefficient (ICC). The ICC was significantly lower in the narrow bandwidth than in the broad bandwidth and the control for both positive symptoms score and total score. While reliability of televideo psychiatric interviews is insufficient using the present narrow-band internet infrastructure, the next generation of infrastructure (broad-band) may permit reliable diagnostic interviews.
The Nitty Gritty: How We Make Analogs Work
NASA Technical Reports Server (NTRS)
Self, A. L.; Huppman, S. R.; Spence, L. A.
2017-01-01
NASA's Human Research Program (HRP) is becoming increasingly reliant on Isolated, Confined and Controlled (ICC) analogs to accomplish many of its research objectives. Compared to other research platforms, ICC analogs present a unique set of operational challenges that must be addressed in order to ensure a high fidelity research environment. In particular, the Human Exploration Research Analog (HERA) habitat, which is classified as an ICC environment, has been developed over the past three years to accommodate the operational needs of research investigations from each of the HRP Elements. During the development period, various types of requirements have contributed to the current operational model, which strives to achieve the highest possible level of mission fidelity with limited resources. This presentation will focus on the operational aspects of the HERA habitat, with emphasis on how we develop the analog research environment to meet researchers' needs. Specific discussion topics include mission scenario development, operational tasks, mission timeline integration, stressor implementation, console support, and improvements based on lessons learned. The information is intended to help investigators better understand the details behind HERA operations and the benefits to their research goals.
Integrated communication and control systems. II - Design considerations
NASA Technical Reports Server (NTRS)
Ray, Asok; Halevi, Yoram
1988-01-01
The ICCS design issues for nonperiodic and stochastic delays are addressed and the framework for alternative design procedures is outlined. The impact of network-induced delays on system stability is investigated and their physical significance is demonstrated using a simulation. The negative effects of vacant sampling and message rejection at the controller are demonstrated.
Brain regulation of appetite in twins12
Melhorn, Susan J; Mehta, Sonya; Kratz, Mario; Tyagi, Vidhi; Webb, Mary F; Noonan, Carolyn J; Buchwald, Dedra S; Goldberg, Jack; Maravilla, Kenneth R; Grabowski, Thomas J; Schur, Ellen A
2016-01-01
Background: Neural responses to highly energetic food cues are robust and are suppressed by eating. It is not known if neural responsiveness to food cues is an inherited trait and possibly even one that mediates the genetic influences on body weight that have been previously observed. Objective: We investigated the inherited influence on brain responses to high-calorie visual food cues before and after a meal. Design: With the use of a monozygotic twin study design, 21 healthy monozygotic twin pairs consumed a standardized breakfast and, 3.5 h later, underwent the first of 2 functional MRI (fMRI) scans with the use of visual food cues. After the first fMRI session, twins consumed a standardized meal, which was followed by the second fMRI. Serial ratings of appetite and food appeal were obtained. An ad libitum buffet was used to measure total caloric and macronutrient intakes. Intraclass correlations (ICCs) were used to test for inherited influences by comparing whether intrapair similarity was greater than interpair similarity. Results: Body mass index was highly correlated within twin pairs (ICC: 0.96; P < 0.0001). ICCs also showed a strong intrapair similarity for the meal-induced change in hunger (ICC: 0.41; P = 0.03), fullness (ICC: 0.39; P = 0.04), and the appeal of fattening food (ICC: 0.57; P < 0.001). Twins ate a similar number of kilocalories at the buffet (ICC: 0.43; P = 0.02). Before the meal, the global brain activation across regions involved in satiety processing was not more similar in twins than in unrelated individuals. However, significant ICCs were present after the meal (ICC: 0.39; P = 0.04) and for the meal-induced change in activation by high-calorie visual food cues (ICC: 0.52; P < 0.01). Conclusion: Inherited factors influence both satiety perception and the effect of a meal to alter regional brain responses to images of highly energetic food. This trial was registered at clinicaltrials.gov as NCT02483663. PMID:26739033
Diagnosing Femoroacetabular Impingement From Plain Radiographs
Ayeni, Olufemi R.; Chan, Kevin; Whelan, Daniel B.; Gandhi, Rajiv; Williams, Dale; Harish, Srinivasan; Choudur, Hema; Chiavaras, Mary M.; Karlsson, Jon; Bhandari, Mohit
2014-01-01
Background: A diagnosis of femoroacetabular impingement (FAI) requires careful history and physical examination, as well as an accurate and reliable radiologic evaluation using plain radiographs as a screening modality. Radiographic markers in the diagnosis of FAI are numerous and not fully validated. In particular, reliability in their assessment across health care providers is unclear. Purpose: To determine inter- and intraobserver reliability between orthopaedic surgeons and musculoskeletal radiologists. Study Design: Cohort study (diagnosis); Level of evidence, 3. Methods: Six physicians (3 orthopaedic surgeons, 3 musculoskeletal radiologists) independently evaluated a broad spectrum of FAI pathologies across 51 hip radiographs on 2 occasions separated by at least 4 weeks. Reviewers used 8 common criteria to diagnose FAI, including (1) pistol-grip deformity, (2) size of alpha angle, (3) femoral head-neck offset, (4) posterior wall sign abnormality, (5) ischial spine sign abnormality, (6) coxa profunda abnormality, (7) crossover sign abnormality, and (8) acetabular protrusion. Agreement was calculated using the intraclass correlation coefficient (ICC). Results: When establishing an FAI diagnosis, there was poor interobserver reliability between the surgeons and radiologists (ICC batch 1 = 0.33; ICC batch 2 = 0.15). In contrast, there was higher interobserver reliability within each specialty, ranging from fair to good (surgeons: ICC batch 1 = 0.72; ICC batch 2 = 0.70 vs radiologists: ICC batch 1 = 0.59; ICC batch 2 = 0.74). Orthopaedic surgeons had the highest interobserver reliability when identifying pistol-grip deformities (ICC = 0.81) or abnormal alpha angles (ICC = 0.81). Similarly, radiologists had the highest agreement for detecting pistol-grip deformities (ICC = 0.75). Conclusion: These results suggest that surgeons and radiologists agree among themselves, but there is a need to improve the reliability of radiographic interpretations for FAI between the 2 specialties. The observed degree of low reliability may ultimately lead to missed, delayed, or inappropriate treatments for patients with symptomatic FAI. PMID:26535344
Romero-Franco, Natalia; Montaño-Munuera, Juan Antonio; Fernández-Domínguez, Juan Carlos; Jiménez-Reyes, Pedro
2017-12-18
New methods are being validated to easily evaluate the knee joint position sense (JPS) due to its role in sports movement and the risk of injury. However, no studies to date have considered the open kinetic chain (OKC) technique, despite the biomechanical differences compared to closed kinetic chain movements. To analyze the validity and reliability of a digital inclinometer to measure the knee JPS in the OKC movement. The validity, inter-tester and intra-tester reliability of a digital inclinometer for measuring knee JPS were evaluated. Sports research laboratory. Eighteen athletes (11 males and 7 females; 28.4 ± 6.6 years; 71.9 ± 14.0 kg; 1.77 ± 0.09 m; 22.8 ± 3.2 kg/m 2 ) voluntary participated in this study. Absolute angular error (AAE), relative angular error (RAE) and variable angular error (VAE) of knee JPS in an OKC. Intraclass correlation coefficient (ICC) and standard error of the mean (SEM) were calculated to determine the validity and reliability of the inclinometer. Data showed excellent validity of the inclinometer to obtain proprioceptive errors compared to the video analysis in JPS tasks (AAE: ICC = 0.981, SEM = 0.08; RAE: ICC = 0.974, SEM = 0.12; VAE: ICC = 0.973, SEM = 0.07). Inter-tester reliability was also excellent for all the proprioceptive errors (AAE: ICC = 0.967, SEM = 0.04; RAE: ICC = 0.974, SEM = 0.03; VAE: ICC = 0.939, SEM = 0.08). Similar results were obtained for intra-tester reliability (AAE: ICC = 0.861, SEM = 0.1; RAE: ICC = 0.894, SEM = 0.1; VAE: ICC = 0.700, SEM = 0.2). The digital inclinometer is a valid and reliable method to assess the knee JPS in OKC. Sport professionals may evaluate the knee JPS to monitor its deterioration during training or improvements throughout the rehabilitation process.
Factors influencing intercultural doctor-patient communication: a realist review.
Paternotte, Emma; van Dulmen, Sandra; van der Lee, Nadine; Scherpbier, Albert J J A; Scheele, Fedde
2015-04-01
Due to migration, doctors see patients from different ethnic backgrounds. This causes challenges for the communication. To develop training programs for doctors in intercultural communication (ICC), it is important to know which barriers and facilitators determine the quality of ICC. This study aimed to provide an overview of the literature and to explore how ICC works. A systematic search was performed to find literature published before October 2012. The search terms used were cultural, communication, healthcare worker. A realist synthesis allowed us to use an explanatory focus to understand the interplay of communication. In total, 145 articles met the inclusion criteria. We found ICC challenges due to language, cultural and social differences, and doctors' assumptions. The mechanisms were described as factors influencing the process of ICC and divided into objectives, core skills and specific skills. The results were synthesized in a framework for the development of training. The quality of ICC is influenced by the context and by the mechanisms. These mechanisms translate into practical points for training, which seem to have similarities with patient-centered communication. Training for improving ICC can be developed as an extension of the existing training for patient-centered communication. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Li, Lin; Zeng, Li; Lin, Zi-Jing; Cazzell, Mary; Liu, Hanli
2015-05-01
Test-retest reliability of neuroimaging measurements is an important concern in the investigation of cognitive functions in the human brain. To date, intraclass correlation coefficients (ICCs), originally used in inter-rater reliability studies in behavioral sciences, have become commonly used metrics in reliability studies on neuroimaging and functional near-infrared spectroscopy (fNIRS). However, as there are six popular forms of ICC, the adequateness of the comprehensive understanding of ICCs will affect how one may appropriately select, use, and interpret ICCs toward a reliability study. We first offer a brief review and tutorial on the statistical rationale of ICCs, including their underlying analysis of variance models and technical definitions, in the context of assessment on intertest reliability. Second, we provide general guidelines on the selection and interpretation of ICCs. Third, we illustrate the proposed approach by using an actual research study to assess intertest reliability of fNIRS-based, volumetric diffuse optical tomography of brain activities stimulated by a risk decision-making protocol. Last, special issues that may arise in reliability assessment using ICCs are discussed and solutions are suggested.
Seguí, María del Mar; Cabrero-García, Julio; Crespo, Ana; Verdú, José; Ronda, Elena
2015-06-01
To design and validate a questionnaire to measure visual symptoms related to exposure to computers in the workplace. Our computer vision syndrome questionnaire (CVS-Q) was based on a literature review and validated through discussion with experts and performance of a pretest, pilot test, and retest. Content validity was evaluated by occupational health, optometry, and ophthalmology experts. Rasch analysis was used in the psychometric evaluation of the questionnaire. Criterion validity was determined by calculating the sensitivity and specificity, receiver operator characteristic curve, and cutoff point. Test-retest repeatability was tested using the intraclass correlation coefficient (ICC) and concordance by Cohen's kappa (κ). The CVS-Q was developed with wide consensus among experts and was well accepted by the target group. It assesses the frequency and intensity of 16 symptoms using a single rating scale (symptom severity) that fits the Rasch rating scale model well. The questionnaire has sensitivity and specificity over 70% and achieved good test-retest repeatability both for the scores obtained [ICC = 0.802; 95% confidence interval (CI): 0.673, 0.884] and CVS classification (κ = 0.612; 95% CI: 0.384, 0.839). The CVS-Q has acceptable psychometric properties, making it a valid and reliable tool to control the visual health of computer workers, and can potentially be used in clinical trials and outcome research. Copyright © 2015 Elsevier Inc. All rights reserved.
Safe motherhood partners -- the International Children's Centre.
1994-01-01
The International Children's Centre (ICC) works worldwide to improve child health in the least developed countries. In its training and research projects the agency contributes to the Safe Motherhood Initiative to improve the health of mothers and infants. ICC is based in Paris, it was established in 1949, and the agency has cooperated with governments, nongovernmental organizations and international bodies like the World Health Organization (WHO) in child care. ICC's activities reflect concern for the health of women before and during pregnancy and the rest of their lives. The center's work comprises training, research, local projects, and information and documentation. Following the 1987 Nairobi conference on safe motherhood, ICC organized a seminar in Paris on maternal mortality in Sub-Saharan francophone Africa, which led to participation in the Safe Motherhood Initiative with a variety of training and research programs. ICC training is integrated, community-based, and multidisciplinary. Anthropology, psychology, economics and management have played a role in ICC training courses. The center runs an international course on maternal and child health from January to April each year and also organizes distance training courses on problem solving in health care. ICC training programs have taken place in Laos, Senegal, and Vietnam to strengthen the work of maternal and child health training centers there. A 4-week course on economic evaluation of health programs is held in Paris each July. In 1989 and 1990, ICC organized in collaboration with WHO safe motherhood workshops on research methodology in Benin and in Burkina Faso with participants from 6 francophone African countries. One research project in Benin is on risk factors for maternal and perinatal mortality and morbidity, and the other in Cameroon on improving surveillance of pregnancy, delivery, and the postnatal period. ICC focuses on long-term planning and action for the benefit of mothers and children.
Crimes against humanity: the role of international courts.
Schneider, Eder Milton; Iglesias, José Roberto; Hallberg, Karen; Kuperman, Marcelo Néstor
2014-01-01
We study the role of international tribunals, like the International Criminal Court (ICC), as an effective way of reducing the number and/or gravity of crimes against humanity. The action of the ICC is directed against leaders that promote or tolerate these kinds of crimes, that is, political authorities, army commanders, civil leaders, etc. In order to simulate the action of the ICC we build a hierarchical society where the most important leaders have the highest connectivity and can spread their points of view, or their orders, through a chain of less but still highly connected deputy chiefs or opinion chieftains. In this way, if they practice misconduct, corruption, or any kind of discriminatory or criminal actions against individuals or groups, it would very difficult and improbable that they will be prosecuted by the courts of their own country. It is to alleviate this situation that the ICC was created. Its mission is to process and condemn crimes against humanity though a supranational organism that can act on criminal leaders in any country. In this study, the action of the ICC is simulated by removing the corrupt leader and replacing it by a "decent" one. However, as the action of the corrupt leader could have spread among the population by the time the ICC acts, we try to determine if a unique action of the ICC is sufficient or if further actions are required, depending on the degree of deterioration of the human rights in the hypothetical country. The results evidence the positive effect of the ICC action with a relatively low number of interventions. The effect of the ICC is also compared with the action of the local national judiciary system.
Crimes against Humanity: The Role of International Courts
Schneider, Éder Milton; Iglesias, José Roberto; Hallberg, Karen; Kuperman, Marcelo Néstor
2014-01-01
We study the role of international tribunals, like the International Criminal Court (ICC), as an effective way of reducing the number and/or gravity of crimes against humanity. The action of the ICC is directed against leaders that promote or tolerate these kinds of crimes, that is, political authorities, army commanders, civil leaders, etc. In order to simulate the action of the ICC we build a hierarchical society where the most important leaders have the highest connectivity and can spread their points of view, or their orders, through a chain of less but still highly connected deputy chiefs or opinion chieftains. In this way, if they practice misconduct, corruption, or any kind of discriminatory or criminal actions against individuals or groups, it would very difficult and improbable that they will be prosecuted by the courts of their own country. It is to alleviate this situation that the ICC was created. Its mission is to process and condemn crimes against humanity though a supranational organism that can act on criminal leaders in any country. In this study, the action of the ICC is simulated by removing the corrupt leader and replacing it by a “decent” one. However, as the action of the corrupt leader could have spread among the population by the time the ICC acts, we try to determine if a unique action of the ICC is sufficient or if further actions are required, depending on the degree of deterioration of the human rights in the hypothetical country. The results evidence the positive effect of the ICC action with a relatively low number of interventions. The effect of the ICC is also compared with the action of the local national judiciary system. PMID:24967894
Kälsch, Julia; Padden, Juliet; Bertram, Stefanie; Pott, Leona L; Reis, Henning; Westerwick, Daniela; Schaefer, Christoph M; Sowa, Jan-P; Möllmann, Dorothe; Fingas, Christian; Dechȇne, Alexander; Sitek, Barbara; Eisenacher, Martin; Canbay, Ali; Ahrens, Maike; Baba, Hideo A
2017-05-01
Discriminating intrahepatic cholangiocarcinoma (ICC) from hepatic metastases of pancreatic ductal adenocarcinoma (mPDAC) can be challenging. While pathologists might depend on clinical information regarding a primary tumor, their diagnosis will lead the patient either to potentially curative surgery (for ICC) or to palliation (for mPDAC). Beyond the validation of recently published potential biomarkers for PDAC (primary or metastatic) in a large cohort, we assessed diagnostic performance of the most promising candidates in the challenging task of discriminating metastatic PDAC (mPDAC) from ICC. In a training set of 87 ICC and 88 pPDAC, our previously identified biomarkers Annexin A1 (ANXA1), ANXA10, and ANXA13 were tested and compared with 11 published biomarkers or panels (MUCIN 1, Agrin, S100P, MUC5 AC, Laminin, VHL, CK 17, N-Cadherin, ELAC2, PODXL and HSPG2). Biomarkers with best results were further tested in an independent series of biopsies of 27 ICC and 36 mPDAC. Highest AUC values (between 0.72 and 0.84) for the discrimination between ICC and pPDAC were found in the training set for Annexin A1, Annexin A10, MUC5 AC, CK17, and N-Cadherin. These markers were further tested on an independent series of liver biopsies containing ICC or mPDAC. Diagnostic characteristics were evaluated for individual markers as well as for 3× panels. ANXA 10 showed the highest diagnostic potential of all single markers, correctly classifying 75% of mPDAC and 85% of ICC. Our results suggest that ANXA10 may be useful to differentiate between ICC and mPDAC, when only a tissue specimen is available.
Sabbatino, Francesco; Villani, Vincenzo; Yearley, Jennifer H.; Deshpande, Vikram; Cai, Lei; Konstantinidis, Ioannis T.; Moon, Christina; Nota, Sjoerd; Wang, Yangyang; Al-Sukaini, Ahmad; Zhu, Andrew X.; Goyal, Lipika; Ting, David T.; Bardeesy, Nabeel; Hong, Theodore S.; Castillo, Carlos Fernandez-del; Tanabe, Kenneth K.; Lillemoe, Keith D.; Ferrone, Soldano; Ferrone, Cristina R.
2017-01-01
Purpose More effective therapy is needed for intrahepatic cholangiocarcinoma (ICC). The encouraging clinical results obtained with checkpoint molecule-specific monoclonal antibodies (mAb) have prompted us to investigate whether this type of immunotherapy may be applicable to ICC. The aims of this study were to determine whether (i) patients mount a T-cell immune response to their ICC, (ii) checkpoint molecules are expressed on both T cells and tumor cells, and (iii) tumor cells are susceptible to recognition by cognate T cells. Experimental Design Twenty-seven ICC tumors were analyzed for (i) lymphocyte infiltrate, (ii) HLA class I and HLA class II expression, and (iii) PD-1 and PD-L1 expression by T cells and ICC cells, respectively. The results of this analysis were correlated with the clinicopathologic characteristics of the patients investigated. Results Lymphocyte infiltrates were identified in all tumors. PD-L1 expression and HLA class I antigen expression by ICC cells was observed in 8 and 11, respectively, of the 27 tumors analyzed. HLA class I antigen expression correlated with CD8+ T-cell infiltrate. Furthermore, positive HLA class I antigen expression in combination with negative/rare PD-L1 expression was associated with favorable clinical course of the disease. Conclusions ICC patients are likely to mount a T-cell immune response against their own tumors. Defects in HLA class I antigen expression in combination with PD-L1 expression by ICC cells provide them with an immune escape mechanism. This mechanism justifies the implementation of immunotherapy with checkpoint molecule-specific mAbs in patients bearing ICC tumors without defects in HLA class I antigen expression. PMID:26373575
NASA Technical Reports Server (NTRS)
Spiering, Barry A.; Lee, Stuart M. C.; Mulavara, Ajitkumar P.; Bentley, Jason, R.; Buxton, Roxanne E.; Lawrence, Emily L.; Sinka, Joseph; Guilliams, Mark E.; Ploutz-Snyder, Lori L.; Bloomberg, Jacob J.
2010-01-01
Spaceflight affects nearly every physiological system. Spaceflight-induced alterations in physiological function translate to decrements in functional performance. Purpose: To develop a test battery for quickly and safely assessing diverse indices of neuromuscular performance. I. Quickly: Battery of tests can be completed in approx.30-40 min. II. Safely: a) No eccentric muscle actions or impact forces. b) Tests present little challenge to postural stability. III. Diverse indices: a) Strength: Excellent reliability (ICC = 0.99) b) Central activation: Very good reliability (ICC = 0.87) c) Power: Excellent reliability (ICC = 0.99) d) Endurance: Total work has excellent reliability (ICC = 0.99) e) Force steadiness: Poor reliability (ICC = 0.20 - 0.60) National
Zhang, J H; Peng, R; Du, Y; Mou, Y; Li, N N; Cheng, L
2016-11-08
Objective: To evaluate the reliability and validity of Parkinson's disease sleep scale-Chinese version (CPDSS) through a study of a large PD population in southwest China, and to explore the prevalence and characteristics of sleep disorders in Parkinson's disease (PD) patients from southwest China. Methods: A total of 544 PD patients and 220 control subjects were enrolled in our study. Demographic data, CPDSS, ESS, PDQ39, HAMD and H-Y stage were assessed in all subjects. Statistical description, Cronbach's alpha coefficient, intra-class correlation coefficient ( ICC ), Spearman rank correlation coefficient and Mann-Whitney U test were used for statistical analyses. Result: The Cronbach's alpha coefficient for CPDSS was 0.79, ICC of the total scale was 0.94 and ICC of each item ranged from 0.73 to 0.97. The factor analysis yielded a five-factor solution, which explained 63.4% of the total variance. Total and each item scores of CPDSS in PD patients were lower than those in healthy controls. 69.3% of PD patients had sleep disorder, while prevalence in the control group was only 29.6%. Negative correlation was found between CPDSS and ESS. Daytime sleepiness was the most common factor (35.9%) leading to sleep disorders. The sleep disorders of PD patients in Southwest China were significantly related with the course of disease, the severity of disease, the quality of life, depression, cognitive level and motor symptoms. Conclusion: CPDSS has good feasibility, reliability and validity in PD population from southwest China. CPDSS is considered as an effective tool for the assessment of sleep disorder in PD patients.
Bessonov, Kyrylo; Walkey, Christopher J.; Shelp, Barry J.; van Vuuren, Hennie J. J.; Chiu, David; van der Merwe, George
2013-01-01
Analyzing time-course expression data captured in microarray datasets is a complex undertaking as the vast and complex data space is represented by a relatively low number of samples as compared to thousands of available genes. Here, we developed the Interdependent Correlation Clustering (ICC) method to analyze relationships that exist among genes conditioned on the expression of a specific target gene in microarray data. Based on Correlation Clustering, the ICC method analyzes a large set of correlation values related to gene expression profiles extracted from given microarray datasets. ICC can be applied to any microarray dataset and any target gene. We applied this method to microarray data generated from wine fermentations and selected NSF1, which encodes a C2H2 zinc finger-type transcription factor, as the target gene. The validity of the method was verified by accurate identifications of the previously known functional roles of NSF1. In addition, we identified and verified potential new functions for this gene; specifically, NSF1 is a negative regulator for the expression of sulfur metabolism genes, the nuclear localization of Nsf1 protein (Nsf1p) is controlled in a sulfur-dependent manner, and the transcription of NSF1 is regulated by Met4p, an important transcriptional activator of sulfur metabolism genes. The inter-disciplinary approach adopted here highlighted the accuracy and relevancy of the ICC method in mining for novel gene functions using complex microarray datasets with a limited number of samples. PMID:24130853
Auplish, Aashima; Clarke, Alison S; Van Zanten, Trent; Abel, Kate; Tham, Charmaine; Bhutia, Thinlay N; Wilks, Colin R; Stevenson, Mark A; Firestone, Simon M
2017-05-01
Educational initiatives targeting at-risk populations have long been recognized as a mainstay of ongoing rabies control efforts. Cluster-based studies are often utilized to assess levels of knowledge, attitudes and practices of a population in response to education campaigns. The design of cluster-based studies requires estimates of intra-cluster correlation coefficients obtained from previous studies. This study estimates the school-level intra-cluster correlation coefficient (ICC) for rabies knowledge change following an educational intervention program. A cross-sectional survey was conducted with 226 students from 7 schools in Sikkim, India, using cluster sampling. In order to assess knowledge uptake, rabies education sessions with pre- and post-session questionnaires were administered. Paired differences of proportions were estimated for questions answered correctly. A mixed effects logistic regression model was developed to estimate school-level and student-level ICCs and to test for associations between gender, age, school location and educational level. The school- and student-level ICCs for rabies knowledge and awareness were 0.04 (95% CI: 0.01, 0.19) and 0.05 (95% CI: 0.2, 0.09), respectively. These ICCs suggest design effect multipliers of 5.45 schools and 1.05 students per school, will be required when estimating sample sizes and designing future cluster randomized trials. There was a good baseline level of rabies knowledge (mean pre-session score 71%), however, key knowledge gaps were identified in understanding appropriate behavior around scared dogs, potential sources of rabies and how to correctly order post rabies exposure precaution steps. After adjusting for the effect of gender, age, school location and education level, school and individual post-session test scores improved by 19%, with similar performance amongst boys and girls attending schools in urban and rural regions. The proportion of participants that were able to correctly order post-exposure precautionary steps following educational intervention increased by 87%. The ICC estimates presented in this study will aid in designing cluster-based studies evaluating educational interventions as part of disease control programs. This study demonstrates the likely benefits of educational intervention incorporating bite prevention and rabies education. Copyright © 2017 Elsevier B.V. All rights reserved.
Lin, Fan; Shi, Jianhui; Wang, Hanlin L; Ma, Xiao-Jun; Monroe, Robert; Luo, Yuling; Chen, Zongming; Liu, Haiyan
2018-05-09
Inconsistent data on detection of albumin expression by ribonucleic acid (RNA) in situ hybridization have been reported. We investigated the utility of RNAscope (Advanced Cell Diagnostics, Hayward, CA) in detection of albumin in hepatocellular carcinomas (HCCs), intrahepatic cholangiocarcinomas (ICCs), and carcinomas from various organs using manual and automated staining. RNAscope for albumin detection was performed on 482 cases on tissue microarray sections and on 22 cases of ICC, including 14 surgical resection and eight core biopsy specimens. Thirty-six of 37 (97%) HCCs had detectable mRNA, whereas all non-HCC and non-ICC cases, except one lung adenocarcinoma, were negative for albumin. Fourteen of 22 ICCs (64%) were positive for albumin. RNAscope for albumin is highly sensitive and specific for identifying HCCs and is highly specific and moderately sensitive for detection of ICCs; however, rare carcinomas (non-HCC, non-ICC, and those with no hepatoid histomorphology) can also have aberrant expression of albumin.
García-Martín, Ana; Lázaro-Rivera, Carla; Fernández-Golfín, Covadonga; Salido-Tahoces, Luisa; Moya-Mur, Jose-Luis; Jiménez-Nacher, Jose-Julio; Casas-Rojo, Eduardo; Aquila, Iolanda; González-Gómez, Ariana; Hernández-Antolín, Rosana; Zamorano, José Luis
2016-07-01
A specialized three-dimensional transoesophageal echocardiography (3D-TOE) reconstruction tool has recently been introduced; the system automatically configures a geometric model of the aortic root from the images obtained by 3D-TOE and performs quantitative analysis of these structures. The aim of this study was to compare the measurements of the aortic annulus (AA) obtained by the new model to that obtained by 3D-TOE and multidetector computed tomography (MDCT) in candidates to transcatheter aortic valve implantation (TAVI) and to assess the reproducibility of this new method. We included 31 patients who underwent TAVI. The AA diameters and area were evaluated by the manual 3D-TOE method and by the automatic software. We showed an excellent correlation between the measurements obtained by both methods: intra-class correlation coefficient (ICC): 0.731 (0.508-0.862), r: 0.742 for AA diameter and ICC: 0.723 (0.662-0.923), r: 0.723 for the AA area, with no significant differences regardless of the method used. The interobserver variability was superior for the automatic measurements than for the manual ones. In a subgroup of 10 patients, we also found an excellent correlation between the automatic measurements and those obtained by MDCT, ICC: 0.941 (0.761-0.985), r: 0.901 for AA diameter and ICC: 0.853 (0.409-0.964), r: 0.744 for the AA area. The new automatic 3D-TOE software allows modelling and quantifying the aortic root from 3D-TOE data with high reproducibility. There is good correlation between the automated measurements and other 3D validated techniques. Our results support its use in clinical practice as an alternative to MDCT previous to TAVI. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
Gagnon, Susie; Gagnon, Marie-Pierre; Turcotte, Stéphane; Lapointe, Jean; Fleet, Richard; Côté, Mario; Beaupré, Pierre; Le Sage, Natalie; Émond, Marcel; Légaré, France
2014-01-01
Background Little is known about factors influencing professionals’ use of wikis. Objective We developed and validated two questionnaires to assess health care professionals’ intention to use wiki-based reminders for the management of trauma patients. Methods We developed questionnaires for emergency physicians (EPs) and allied health professions (AHPs) based on the Theory of Planned Behavior and adapted them to the salient beliefs of each, identified in an earlier study. Items measured demographics and direct and indirect theoretical constructs. We piloted the questionnaires with 2 focus groups (5 EPs and 5 AHPs) to identify problems of wording and length. Based on feedback, we adjusted the wording and combined certain items. A new convenience sample of 25 EPs and 26 AHPs then performed a test-retest of the questionnaires at a 2-week interval. We assessed internal consistency using Cronbach alpha coefficients and temporal stability of items with an agreement intraclass correlation coefficient (ICC). Results Five EPs and 5 AHPs (3 nurses, 1 respiratory therapist, and 1 pharmacist) formed 2 focus groups; 25 EPs and 26 AHPs (12 nurses, 7 respiratory therapists, and 7 pharmacists) completed the test and retest. The EP questionnaire test-retest scores for consistency (Cronbach alpha) and stability (ICC) were intention (test: Cronbach alpha=.94; retest: Cronbach alpha=.98; ICC=.89), attitude (.74, .72, .70), subjective norm (.79, .78, .75), perceived behavioral control (.67, .65, .66), attitudinal beliefs (.94, .86, .60), normative beliefs (.83, .87, .79), and control beliefs barriers (.58, .67, .78) and facilitators (.97, .85, .30). The AHP questionnaire scores for consistency and stability were: intention (test Cronbach alpha=.69, retest Cronbach alpha=.81, ICC=.48), attitude (.85, .87, .83), subjective norm (.47, .82, .62), perceived behavioral control (.55, .62, .60), attitudinal beliefs (.92, .91, .82), normative beliefs (.85, .90, .74), and control beliefs barriers (.58, .55, .66) and facilitators (.72, .94, –.05). To improve the psychometric properties of both questionnaires, we reformulated poorly consistent or unstable items. Conclusions Our new theory-based questionnaires to measure health care professionals’ intention to use wiki-based reminders have adequate validity and reliability for use in large surveys. In the long run, they can be used to develop a theory-based implementation intervention for a wiki promoting best practices in trauma care. PMID:25281856
Archambault, Patrick Michel; Gagnon, Susie; Gagnon, Marie-Pierre; Turcotte, Stéphane; Lapointe, Jean; Fleet, Richard; Côté, Mario; Beaupré, Pierre; Le Sage, Natalie; Emond, Marcel; Légaré, France
2014-10-03
Little is known about factors influencing professionals' use of wikis. We developed and validated two questionnaires to assess health care professionals' intention to use wiki-based reminders for the management of trauma patients. We developed questionnaires for emergency physicians (EPs) and allied health professions (AHPs) based on the Theory of Planned Behavior and adapted them to the salient beliefs of each, identified in an earlier study. Items measured demographics and direct and indirect theoretical constructs. We piloted the questionnaires with 2 focus groups (5 EPs and 5 AHPs) to identify problems of wording and length. Based on feedback, we adjusted the wording and combined certain items. A new convenience sample of 25 EPs and 26 AHPs then performed a test-retest of the questionnaires at a 2-week interval. We assessed internal consistency using Cronbach alpha coefficients and temporal stability of items with an agreement intraclass correlation coefficient (ICC). Five EPs and 5 AHPs (3 nurses, 1 respiratory therapist, and 1 pharmacist) formed 2 focus groups; 25 EPs and 26 AHPs (12 nurses, 7 respiratory therapists, and 7 pharmacists) completed the test and retest. The EP questionnaire test-retest scores for consistency (Cronbach alpha) and stability (ICC) were intention (test: Cronbach alpha=.94; retest: Cronbach alpha=.98; ICC=.89), attitude (.74, .72, .70), subjective norm (.79, .78, .75), perceived behavioral control (.67, .65, .66), attitudinal beliefs (.94, .86, .60), normative beliefs (.83, .87, .79), and control beliefs barriers (.58, .67, .78) and facilitators (.97, .85, .30). The AHP questionnaire scores for consistency and stability were: intention (test Cronbach alpha=.69, retest Cronbach alpha=.81, ICC=.48), attitude (.85, .87, .83), subjective norm (.47, .82, .62), perceived behavioral control (.55, .62, .60), attitudinal beliefs (.92, .91, .82), normative beliefs (.85, .90, .74), and control beliefs barriers (.58, .55, .66) and facilitators (.72, .94, -.05). To improve the psychometric properties of both questionnaires, we reformulated poorly consistent or unstable items. Our new theory-based questionnaires to measure health care professionals' intention to use wiki-based reminders have adequate validity and reliability for use in large surveys. In the long run, they can be used to develop a theory-based implementation intervention for a wiki promoting best practices in trauma care.
Ferrone, Cristina R; Ting, David T; Shahid, Mohammed; Konstantinidis, Ioannis T; Sabbatino, Francesco; Goyal, Lipika; Rice-Stitt, Travis; Mubeen, Ayesha; Arora, Kshitij; Bardeesey, Nabeel; Miura, John; Gamblin, T Clark; Zhu, Andrew X; Borger, Darrell; Lillemoe, Keith D; Rivera, Miguel N; Deshpande, Vikram
2016-01-01
Intrahepatic cholangiocarcinoma (ICC) often is a diagnosis determined by exclusion. Distinguishing ICC from other metastatic adenocarcinomas based on histopathologic or immunohistochemical analysis often is difficult and requires an extensive workup. This study aimed to determine whether albumin, whose expression is restricted to the liver, has potential as a biomarker for ICC using a novel and highly sensitive RNA in situ hybridization (ISH) platform. Modified branched DNA probes were developed for albumin RNA ISH. The study evaluated 467 patient samples of primary and metastatic lesions. Of the 467 samples evaluated, 83 were ICCs, 42 were hepatocellular carcinomas (HCCs), and 332 were nonhepatic carcinomas including tumors arising from the perihilar region and bile duct, pancreas, stomach, esophagus, colon, breast, ovary, endometrium, kidney, and urinary bladder. Albumin RNA ISH was highly sensitive for cancers of liver origin, staining positive in 82 (99 %) of 83 ICCs and in 42 HCCs (100 %). Perihilar and distal bile duct carcinomas as well as carcinomas arising at other sites tested negative for albumin. Notably, 6 (22 %) of 27 intrahepatic tumors previously diagnosed as carcinomas of undetermined origin tested positive for albumin. Albumin RNA ISH is a sensitive and highly specific diagnostic tool for distinguishing ICC from metastatic adenocarcinoma to the liver or carcinoma of unknown origin. Albumin RNA ISH could replace the extensive diagnostic workup, leading to timely confirmation of the ICC diagnosis. Additionally, the assay could serve as a guide to distinguish ICC from perihilar adenocarcinoma.
Hirst, G D S; Beckett, E A H; Sanders, K M; Ward, S M
2002-01-01
When intracellular recordings were made from the antral region of murine stomach, cells with three different patterns of electrical activity were detected. One group of cells generated follower potentials, the second group generated pacemaker potentials and the third group generated slow waves that consisted of primary and secondary components. Slow waves recorded in different regions of the gastric antrum had similar amplitudes but different characteristic shapes. At the greater curvature, slow waves had large initial components. Midway between the greater and lesser curvature, the amplitude of the initial component was reduced and at the lesser curvature an initial component was difficult to detect. When the distributions of myenteric (ICC-MY) and intramuscular interstitial cells of Cajal (ICC-IM) were determined, using an antibody to Kit, ICC-MY were found to be present at the greater curvature but were greatly reduced in density at the lesser curvature. In contrast, ICC-IM were found in the circular layer of each region. When recordings were made from the antrum of W/WV mice, which lack ICC-IM, incomplete slow waves were detected and their amplitudes fell from the greater to the lesser curvature. Again, a corresponding fall in the density of ICC-MY was detected. The observations indicate that the contribution of ICC-MY and ICC-IM to the generation of slow waves varies in different regions of the mouse gastric antrum. PMID:11986385
Zhang, Changhe; Xu, Hong; Zhou, Zhenping; Tian, Ye; Cao, Xiaofei; Cheng, Guochang; Liu, Qinghong
2018-01-01
Epidermal growth factor receptor (EGFR) and downstream signal transducer and activator of transcription 3 (STAT3) signaling have been extensively implicated in various human neoplasms. Recently, a novel EGFR inhibitor, known as afatinib, has exhibited broad antitumor activities in a variety of tumors. Therefore, the present study attempted to investigate the impact of this agent on intrahepatic cholangiocarcinoma (ICC). Initially, immunohistochemical assays were performed on 15 human ICC specimens and their adjacent tissues in order to assess the protein levels of phosphorylated EGFR (pEGFR) and pSTAT3. Subsequently, the human ICC cell lines JCK and OZ were exposed to different doses of afatinib, and then cell viability and apoptosis were determined by MTT assay and flow cytometry, respectively. Furthermore, immunoblotting was applied to detect any variations in the phosphorylated protein levels of EGFR and STAT3 in afatinib-treated ICC cells. The results of the current study demonstrated that ICC specimens had evidently increased pEGFR and pSTAT3 protein levels as compared with the adjacent noncancerous tissues. Further in vitro experiments indicated that afatinib evidently blocked ICC cell growth and induced cell apoptosis. At the protein level, pEGFR and pSTAT3 were evidently attenuated by afatinib-administration. In conclusion, the present study clearly determined that afatinib exerts an antitumor effect on ICC cells by silencing the EGFR-STAT3 signaling pathway. This novel agent deserves further investigation as a potential therapeutic strategy for ICC. PMID:29805522
Kuziemsky, Craig E; Varpio, Lara
2011-08-01
As more healthcare delivery is provided by collaborative teams there is a need for enhanced design of health information systems (HISs) to support collaborative care delivery. The purpose of this study was to develop a model of the different types of awareness that exist in interprofessional collaborative care (ICC) delivery to inform HIS design to support ICC. Qualitative data collection and analysis was done. The data sources consisted of 90 h of non-participant observations and 30 interviews with nurses, physicians, medical residents, volunteers, and personal support workers. Many of the macro-level ICC activities (e.g. morning rounds, shift change) were constituted by micro-level activities that involved different types of awareness. We identified four primary types of ICC awareness: patient, team member, decision making, and environment. Each type of awareness is discussed and supported by study data. We also discuss implication of our findings for enhanced design of existing HISs as well as providing insight on how HISs could be better designed to support ICC awareness. Awareness is a complex yet crucial piece of successful ICC. The information sources that provided and supported ICC awareness were varied. The different types of awareness from the model can help us understand the explicit details of how care providers communicate and exchange information with one another. Increased understanding of ICC awareness can assist with the design and evaluation of HISs to support collaborative activities. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Pan-mTOR inhibitor MLN0128 is effective against intrahepatic cholangiocarcinoma in mice.
Zhang, Shanshan; Song, Xinhua; Cao, Dan; Xu, Zhong; Fan, Biao; Che, Li; Hu, Junjie; Chen, Bin; Dong, Mingjie; Pilo, Maria G; Cigliano, Antonio; Evert, Katja; Ribback, Silvia; Dombrowski, Frank; Pascale, Rosa M; Cossu, Antonio; Vidili, Gianpaolo; Porcu, Alberto; Simile, Maria M; Pes, Giovanni M; Giannelli, Gianluigi; Gordan, John; Wei, Lixin; Evert, Matthias; Cong, Wenming; Calvisi, Diego F; Chen, Xin
2017-12-01
Intrahepatic cholangiocarcinoma (ICC) is a lethal malignancy without effective treatment options. MLN0128, a second generation pan-mTOR inhibitor, shows efficacy for multiple tumor types. We evaluated the therapeutic potential of MLN0128 vs. gemcitabine/oxaliplatin in a novel ICC mouse model. We established a novel ICC mouse model via hydrodynamic transfection of activated forms of AKT (myr-AKT) and Yap (YapS127A) protooncogenes (that will be referred to as AKT/YapS127A). Genetic approaches were applied to study the requirement of mTORC1 and mTORC2 in mediating AKT/YapS127A driven tumorigenesis. Gemcitabine/oxaliplatin and MLN0128 were administered in AKT/YapS127A tumor-bearing mice to study their anti-tumor efficacy in vivo. Multiple human ICC cell lines were used for in vitro experiments. Hematoxylin and eosin staining, immunohistochemistry and immunoblotting were applied for the characterization and mechanistic study. Co-expression of myr-AKT and YapS127A promoted ICC development in mice. Both mTORC1 and mTORC2 complexes were required for AKT/YapS127A ICC development. Gemcitabine/oxaliplatin had limited efficacy in treating late stage AKT/YapS127A ICC. In contrast, partial tumor regression was achieved when MLN0128 was applied in the late stage of AKT/YapS127A cholangiocarcinogenesis. Furthermore, when MLN0128 was administered in the early stage of AKT/YapS127A carcinogenesis, it led to disease stabilization. Mechanistically, MLN0128 efficiently inhibited AKT/mTOR signaling both in vivo and in vitro, inducing strong ICC cell apoptosis and only marginally affecting proliferation. This study suggests that mTOR kinase inhibitors may be beneficial for the treatment of ICC, even in tumors that are resistant to standard of care chemotherapeutics, such as gemcitabine/oxaliplatin-based regimens, especially in the subset of tumors exhibiting activated AKT/mTOR cascade. Lay summary: We established a novel mouse model of intrahepatic cholangiocarcinoma (ICC). Using this new preclinical model, we evaluated the therapeutic potential of mTOR inhibitor MLN0128 vs. gemcitabine/oxaliplatin (the standard chemotherapy for ICC treatment). Our study shows the anti-neoplastic potential of MLN0128, suggesting that it may be superior to gemcitabine/oxaliplatin-based chemotherapy for the treatment of ICC, especially in the tumors exhibiting activated AKT/mTOR cascade. Copyright © 2017 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.
Reliability of a new test battery for fitness assessment of the European Astronaut corps.
Petersen, Nora; Thieschäfer, Lutz; Ploutz-Snyder, Lori; Damann, Volker; Mester, Joachim
2015-01-01
To optimise health for space missions, European astronauts follow specific conditioning programs before, during and after their flights. To evaluate the effectiveness of these programs, the European Space Agency conducts an Astronaut Fitness Assessment (AFA), but the test-retest reliability of elements within it remains unexamined. The reliability study described here presents a scientific basis for implementing the AFA, but also highlights challenges faced by operational teams supporting humans in such unique environments, especially with respect to health and fitness monitoring of crew members travelling not only into space, but also across the world. The AFA tests assessed parameters known to be affected by prolonged exposure to microgravity: aerobic capacity (VO2max), muscular strength (one repetition max, 1 RM) and power (vertical jumps), core stability, flexibility and balance. Intraclass correlation coefficients (ICC3.1), standard error of measurement and coefficient of variation were used to assess relative and absolute test-retest reliability. Squat and bench 1 RM (ICC3.1 = 0.94-0.99), hip flexion (ICC3.1 = 0.99) and left and right handgrip strength (ICC3.1 = 0.95 and 0.97), showed the highest test-retest reliability, followed by VO2max (ICC3.1 = 0.91), core strength (ICC3.1 = 0.78-0.89), hip extension (ICC3.1 = 0.63), the countermeasure (ICC3.1 = 0.76) and squat (ICC3.1 = 0.63) jumps, and single right- and left-leg jump height (ICC3.1 = 0.51 and 0.14). For balance, relative reliability ranged from ICC3.1 = 0.78 for path length (two legs, head tilted back, eyes open) to ICC3.1 = 0.04 for average rotation velocity (one leg, eyes closed). In a small sample (n = 8) of young, healthy individuals, the AFA battery of tests demonstrated acceptable test-retest reliability for most parameters except some balance and single-leg jump tasks. These findings suggest that, for the application with astronauts, most AFA tests appear appropriate to be maintained in the test battery, but that some elements may be unreliable, and require either modification (duration, selection of task) or removal (single-leg jump, balance test on sphere) from the battery. The test battery is mobile and universally applicable for occupational and general fitness assessment by its comprehensive composition of tests covering many systems involved in whole body movement.
Naser, Asieh Zamani; Mehr, Bahar Behdad
2013-01-01
Cross- sectional tomograms have been used for optimal pre-operative planning of dental implant placement. The aim of the present study was to assess the accuracy of Cone Beam Computed Tomography (CBCT) measurements of specific distances around the mandibular canal by comparing them to those obtained from Multi-Slice Computed Tomography (MSCT) images. Ten hemi-mandible specimens were examined using CBCT and MSCT. Before imaging, wires were placed at 7 locations between the anterior margin of the third molar and the anterior margin of the second premolar as reference points. Following distances were measured by two observers on each cross-sectional CBCT and MSCT image: Mandibular Width (W), Length (L), Upper Distance (UD), Lower Distance (LD), Buccal Distance (BD), and Lingual Distance (LID). The obtained data were evaluated using SPSS software, applying paired t-test and intra-class correlation coefficient (ICC). There was a significant difference between the values obtained by MSCT and CBCT measurement for all areas such as H, W, UD, LD, BD, and LID, (P < 0.001), with a difference less than 1 mm. The ICC for all distances by both techniques, measured by a single observer with a one week interval and between 2 observers was 99% and 98%, respectively. Comparing the obtained data of both techniques indicates that the difference between two techniques is 2.17% relative to MSCT. The results of this study showed that there is significant difference between measurements obtained by CBCT and MSCT. However, the difference is not clinically significant.
Abbo, C; Okello, E S; Nakku, J
2013-03-01
The Global Assessment of Functioning (GAF) is the standard method and an essential tool for representing a clinician's judgment of a patient's overall level of psychological, social and occupational functioning. As such, it is probably the single most widely used method for assessing impairment among the patients with psychiatric illnesses. To assess the effects of one-hour training on application of the GAF by Psychiatric Clinical Officers' in a Ugandan setting. Five Psychiatrists and five Psychiatric Clinical Officers (PCOs) or Assistant Medical Officers who hold a 2 year diploma in Clinical Psychiatry were randomly selected to independently rate a video-recorded psychiatric interview according to the DSM IV-TR. The PCOs were then offered a one-hour training on how to rate the GAF scale and asked to rate the video case interview again. All ratings were assigned on the basis of past one year, at admission and current functioning. Interclass correlations (ICC) were computed using two-way mixed models. The ICC between the psychiatrists and the PCOs before training in the past one year, at admission and current functioning were +0.48, +0.51 and +0.59 respectively. After training, the ICC coefficients were +0.60, +0.82 and +0.83. Brief training given to PCOs improved the applications of their ratings of GAF scale to acceptable levels. There is need for formal training to this cadre of psychiatric practitioners in the use of the GAF.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rafi, Shoaib; Piduru, Sarat M.; El-Rayes, Bassel
To assess the overall survival, efficacy, and safety of radioembolization with yttrium-90 (Y90) for unresectable standard-chemorefractory intrahepatic cholangiocarcinoma (ICC). Patients with unresectable standard-chemorefractory ICC treated with Y90 were studied. Survival was calculated from the date of first Y90 procedure. Tumor response was assessed with the Response Evaluation Criteria in Solid Tumors criteria on follow-up computed tomography or magnetic resonance imaging scans. National Cancer Institute Common Terminology Criteria (NCI CTCAE), version 3, were used for complications. Statistical analysis was performed by the Kaplan-Meier estimator by the log rank test. Nineteen patients underwent a total of 24 resin-based Y90 treatments. Median survivalmore » from the time of diagnosis and first Y90 procedure was 752 {+-} 193 [95 % confidence interval (CI) 374-1130] and 345 {+-} 128 (95 % CI 95-595) days, respectively. Median survival with Eastern Cooperative Oncology Group (ECOG) performance status 1 (n = 15) and ECOG performance status 2 (n = 4) was 450 {+-} 190 (95 % CI 78-822) and 345 {+-} 227 (95 % CI 0-790) days, respectively (p = .214). Patients with extrahepatic metastasis (n = 11) had a median survival of 404 {+-} 309 (95 % CI 0-1010) days versus 345 {+-} 117 (95 % CI 115-575) days for patients without metastasis (n = 8) (p = .491). No mortality was reported within 30 days from first Y90 radioembolization. One patient developed grade 3 thrombocytopenia as assessed by NCI CTCAE. Fatigue and transient abdominal pain were observed in 4 (21 %) and 6 (32 %) patients, respectively. Y90 radioembolization is effective for unresectable standard-chemorefractory ICC.« less
Javanshir, Khodabakhsh; Mohseni-Bandpei, Mohammad Ali; Rezasoltani, Asghar; Amiri, Mohsen; Rahgozar, Mehdi
2011-01-01
In this study, the reliability of the longus colli muscle (LCM) size was assessed in a relaxed state by a real time ultrasonography (US) device in a group of healthy subjects and a group of patients with chronic neck pain. Fifteen healthy subjects (19-41 years old) and 10 patients with chronic neck pain (27-44 years old) were recruited for the purpose of this study. LCM size was measured at the level of thyroid cartilage. Two images were taken on the same day with an hour interval to assess the within day reliability and the third image was taken 1 week later to determine between days reliability. Cross sectional area (CSA), anterior posterior dimension (APD), and lateral dimension (LD) were measured each time. The shape ratio was calculated as LD/APD. Intraclass correlation coefficients (ICC) and standard error of measurement (SEM) were computed for data analysis. The ICC of left and right CSA for within day and between days reliability in healthy subjects were (0.90, 0.93) and (0.85, 0.82), respectively. The ICC of left and right CSA for within day and between days reliability in patients with neck pain were (0.86, 0.82) and (0.76, 0.81), respectively. The results indicated that US could be used as a reliable tool to measure the LCM dimensions in healthy subjects and patients with chronic neck pain. Copyright © 2009 Elsevier Ltd. All rights reserved.
Petretta, Robert; Strelzow, Jason; Ohly, Nicholas E; Misur, Peter; Masri, Bassam A
2015-12-01
Templating is an important aspect of preoperative planning for total hip arthroplasty and can help determine the size and positioning of the prosthesis. Historically, templating has been performed using acetate templates over printed radiographs. As a result of the increasing use of digital imaging, surgeons now either obtain additional printed radiographs solely for templating purposes or use specialized digital templating software, both of which carry additional cost. The purposes of this study was to compare acetate templating of digitally calibrated images on an LCD monitor to digital templating in terms of (1) accuracy; (2) reproducibility; and (3) time efficiency. Acetate onlay templating was performed directly over digital radiographs on an LCD monitor and was compared with digital templating. Five separate observers participated in this study templating on 52 total hip arthroplasties. For the acetate templating, the digital images were magnified to the scaled reference on the templates provided by the manufacturer (ratio 1.2:1) before templating using a 25-mm marker as a reference. Both the acetate and digital templating results were then compared with the actual implanted components to determine accuracy. Interobserver and intraobserver variability was determined by an intraclass correlation coefficient. Observers recorded time to complete templating from the time of complete upload of patients' imaging onto the system to completion of templating. Both acetate and digital templates demonstrated moderate accuracy in predicting within one size of the eventual implanted acetabular cup (77% [199 of 260]; 70% [181 of 260], respectively; p = 0.050; 95% confidence interval [CI], 0.058-0.32), whereas acetate templating was better at predicting the femoral stem compared to digital templating (75% [195 of 260]; 60% [155 of 260], respectively; p < 0.001; 95% CI, 0.084-0.32). Acetate templating showed moderate to substantial interobserver agreement (cup intraclass correlation coefficient [ICC] = 0.55; 95% CI, 0.14-0.86; femoral ICC = 0.75; 95% CI, 0.39-0.95) and both methods showed almost perfect intraobserver agreement in reproducibility (acetate cup ICC = 0.82; 95% CI, 0.66-0.97; acetate femoral ICC = 0.86; 95% CI, 0.74-0.97; digital cup ICC = 0.82; 95% CI, 0.68-0.97; digital femoral ICC = 0.88; 95% CI, 0.77-1.0). Acetate templating could be performed more quickly (acetate mean 119 seconds; range, 37-220 seconds versus 154 seconds; range, 73-343 seconds; p < 0.001). Acetate onlay templating on digitally calibrated images can be a reliable substitute for digital templating using specialized software. It is quicker to perform and much less expensive. Hospitals and practices need not purchase expensive software, particularly at lower volume centers. Level III, diagnostic study.
A Study on ESL Teachers' Intercultural Communication Competence
ERIC Educational Resources Information Center
Zhang, Yechun
2017-01-01
Intercultural Communication Competence (ICC) is the absolute necessity for talents in the 21st century. Meanwhile, the development of ICC competence has already become a new teaching concept, which will penetrate in all aspects of language teaching activities. Indeed, to facilitate language learners to develop ICC, language teachers, especially…
76 FR 80941 - Request for Connect America Fund Cost Models
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-27
... interested parties to submit forward-looking cost models, consistent with the USF/ICC Transformation Order... forward-looking cost model consistent with the USF/ICC Transformation Order no later than December 30.... SUPPLEMENTARY INFORMATION: 1. On November 18, 2011, the Commission released the USF/ICC Transformation Order, 76...
ERIC Educational Resources Information Center
Schulz, Wolfram, Ed.; Ainley, John, Ed.; Fraillon, Julian, Ed.
2011-01-01
This report is structured so as to provide technical detail about each aspect of International Civic and Citizenship Education Study (ICCS). The overview is followed by a series of chapters that provide detail about different aspects of ICCS. Chapters, 2, 3, 4, and 5 are concerned with the instruments. Chapter 2 provides information about the…
[Cellular mechanism of the generation of spontaneous activity in gastric muscle].
Nakamura, Eri; Kito, Yoshihiko; Fukuta, Hiroyasu; Yanai, Yoshimasa; Hashitani, Hikaru; Yamamoto, Yoshimichi; Suzuki, Hikaru
2004-03-01
In gastric smooth muscles, interstitial cells of Cajal (ICC) might be the pacemaker cells of spontaneous activities since ICC are rich in mitochondria and are connected with smooth muscle cells via gap junctions. Several types of ICC are distributed widely in the stomach wall. A group of ICC distributed in the myenteric layer (ICC-MY) were the pacemaker cells of gastrointestinal smooth muscles. Pacemaker potentials were generated in ICC-MY, and the potentials were conducted to circular smooth muscles to trigger slow waves and also conducted to longitudinal muscles to form follower potentials. In circular muscle preparations, interstitial cells distributed within muscle bundles (ICC-IM) produced unitary potentials, which were conducted to circular muscles to form slow potentials by summation. In mutant mice lacking inositol trisphosphate (IP(3)) receptor, slow waves were absent in gastric smooth muscles. The generation of spontaneous activity was impaired by the inhibition of Ca(2+)-release from internal stores through IP(3) receptors, inhibition of mitochondrial Ca(2+)-handling with proton pump inhibitors, and inhibition of ATP-sensitive K(+)-channels at the mitochondrial inner membrane. These results suggested that mitochondrial Ca(2+)-handling causes the generation of spontaneous activity in pacemaker cells. Possible involvement of protein kinase C (PKC) in the Ca(2+) signaling system was also suggested.
Austin, Paul F; Bauer, Stuart B; Bower, Wendy; Chase, Janet; Franco, Israel; Hoebeke, Piet; Rittig, Søren; Walle, Johan Vande; von Gontard, Alexander; Wright, Anne; Yang, Stephen S; Nevéus, Tryggve
2016-04-01
The impact of the original International Children's Continence Society (ICCS) terminology document on lower urinary tract (LUT) function resulted in the global establishment of uniformity and clarity in the characterization of LUT function and dysfunction in children across multiple healthcare disciplines. The present document serves as a stand-alone terminology update reflecting refinement and current advancement of knowledge on pediatric LUT function. A variety of worldwide experts from multiple disciplines within the ICCS leadership who care for children with LUT dysfunction were assembled as part of the standardization committee. A critical review of the previous ICCS terminology document and the current literature was performed. Additionally, contributions and feedback from the multidisciplinary ICCS membership were solicited. Following a review of the literature over the last 7 years, the ICCS experts assembled a new terminology document reflecting current understanding of bladder function and LUT dysfunction in children using the resources from the literature review, expert opinion and ICCS member feedback. The present ICCS terminology document provides a current and consensus update to the evolving terminology and understanding of LUT function in children. Neurourol. Urodynam. 35:471-481, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Spatial and temporal clonal evolution of intrahepatic cholangiocarcinoma.
Dong, Liang-Qing; Shi, Yang; Ma, Li-Jie; Yang, Liu-Xiao; Wang, Xiao-Ying; Zhang, Shu; Wang, Zhi-Chao; Duan, Meng; Zhang, Zhao; Liu, Long-Zi; Zheng, Bo-Hao; Ding, Zhen-Bin; Ke, Ai-Wu; Gao, Da-Ming; Yuan, Ke; Zhou, Jian; Fan, Jia; Xi, Ruibin; Gao, Qiang
2018-07-01
Intrahepatic cholangiocarcinoma (ICC) is the second-most lethal primary liver cancer. Little is known about intratumoral heterogeneity (ITH) and its impact on ICC progression. We aimed to investigate the ITH of ICC in the hope of helping to develop new therapeutic strategies. We obtained 69 spatially distinct regions from six operable ICCs. Patient-derived primary cancer cells (PDPCs) were established for each region, followed by whole-exome sequencing (WES) and multi-level validation. We observed widespread ITH for both somatic mutations and clonal architecture, shaped by multiple mechanisms, like clonal "illusion", parallel evolution and chromosome instability. A median of 60.3% of mutations were heterogeneous, among which 85% of the driver mutations were located on the branches of tumor phylogenetic trees. Many truncal and clonal driver mutations occurred in tumor suppressor genes, such as TP53, SMARCB1 and PBRM1 that are involved in DNA repair and chromatin-remodeling. Genome doubling occurred in most cases (5/6) after the accumulation of truncal mutations and was shared by all intratumoral sub-regions. In all cases, ongoing chromosomal instability is evident throughout the evolutionary trajectory of ICC. The recurrence of ICC1239 provided evidence to support the polyclonal metastatic seeding in ICC. The change of mutation landscape and internal diversity among subclones during metastasis, such as the loss of chemoresistance mediator, can be used for new treatment strategies. Targeted therapy against truncal alterations, such as IDH1, JAK1, and KRAS mutations and EGFR amplification, was developed in 5/6 patients. Integrated investigations of spatial ITH and clonal evolution may provide an important molecular foundation for enhanced understanding of tumorigenesis and progression in ICC. We applied multiregional whole-exome sequencing to investigate the evolution of intrahepatic cholangiocarcinoma (ICC). The results revealed that many factors, such as parallel evolution and chromosome instability, may participate and promote the branch diversity of ICC. Interestingly, in one patient with primary and recurrent metastatic tumors, we found evidence of polyclonal metastatic seeding, indicating that symbiotic communities of multiple clones existed and were maintained during metastasis. More realistically, some truncal alterations, such as IDH1, JAK1, and KRAS mutations and EGFR amplification, could be promising treatment targets in patients with ICC. Copyright © 2018 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.
Ward, Mary H.; Bell, Erin M.; Whitehead, Todd P.; Gunier, Robert B.; Friesen, Melissa C.; Nuckols, John R.
2013-01-01
Background: Residential pesticide exposure has been linked to adverse health outcomes in adults and children. High-quality exposure estimates are critical for confirming these associations. Past epidemiologic studies have used one measurement of pesticide concentrations in carpet dust to characterize an individual’s average long-term exposure. If concentrations vary over time, this approach could substantially misclassify exposure and attenuate risk estimates. Objectives: We assessed the repeatability of pesticide concentrations in carpet dust samples and the potential attenuation bias in epidemiologic studies relying on one sample. Methods: We collected repeated carpet dust samples (median = 3; range, 1–7) from 21 homes in Fresno County, California, during 2003–2005. Dust was analyzed for 13 pesticides using gas chromatography–mass spectrometry. We used mixed-effects models to estimate between- and within-home variance. For each pesticide, we computed intraclass correlation coefficients (ICCs) and the estimated attenuation of regression coefficients in a hypothetical case–control study collecting a single dust sample. Results: The median ICC was 0.73 (range, 0.37–0.95), demonstrating higher between-home than within-home variability for most pesticides. The expected magnitude of attenuation bias associated with using a single dust sample was estimated to be ≤ 30% for 7 of the 13 compounds evaluated. Conclusions: For several pesticides studied, use of one dust sample to represent an exposure period of approximately 2 years would not be expected to substantially attenuate odds ratios. Further study is needed to determine if our findings hold for longer exposure periods and for other pesticides. PMID:23462689
Liu, Meng-Qi; Chen, Zhi-Ye; Ma, Lin
2018-03-30
Objective To evaluate the reliability of three dimensional spiral fast spin echo pseudo-continuous arterial spin labeling (3D pc-ASL) in measuring cerebral blood flow (CBF) with different post-labeling delay time (PLD) in the resting state and the right finger taping state. Methods 3D pc-ASL and three dimensional T1-weighted fast spoiled gradient recalled echo (3D T1-FSPGR) sequence were applied to eight healthy subjects twice at the same time each day for one week interval. ASL data acquisition was performed with post-labeling delay time (PLD) 1.5 seconds and 2.0 seconds in the resting state and the right finger taping state respectively. CBF mapping was calculated and CBF value of both the gray matter (GM) and white matter (WM) was automatically extracted. The reliability was evaluated using the intraclass correlation coefficient (ICC) and Bland and Altman plot. Results ICC of the GM (0.84) and WM (0.92) was lower at PLD 1.5 seconds than that (GM, 0.88; WM, 0.94) at PLD 2.0 seconds in the resting state, and ICC of GM (0.88) was higher in the right finger taping state than that in the resting state at PLD 1.5 seconds. ICC of the GM and WM was 0.71 and 0.78 for PLD 1.5 seconds and PLD 2.0 seconds in the resting state at the first scan, and ICC of the GM and WM was 0.83 and 0.79 at the second scan, respectively. Conclusion This work demonstrated that 3D pc-ASL might be a reliable imaging technique to measure CBF over the whole brain at different PLD in the resting state or controlled state.
Reproducibility of ad libitum energy intake with the use of a computerized vending machine system123
Votruba, Susanne B; Franks, Paul W; Krakoff, Jonathan; Salbe, Arline D
2010-01-01
Background: Accurate assessment of energy intake is difficult but critical for the evaluation of eating behavior and intervention effects. Consequently, methods to assess ad libitum energy intake under controlled conditions have been developed. Objective: Our objective was to evaluate the reproducibility of ad libitum energy intake with the use of a computerized vending machine system. Design: Twelve individuals (mean ± SD: 36 ± 8 y old; 41 ± 8% body fat) consumed a weight-maintaining diet for 3 d; subsequently, they self-selected all food with the use of a computerized vending machine system for an additional 3 d. Mean daily energy intake was calculated from the actual weight of foods consumed and expressed as a percentage of weight-maintenance energy needs (%WMEN). Subjects repeated the study multiple times during 2 y. The within-person reproducibility of energy intake was determined through the calculation of the intraclass correlation coefficients (ICCs) between visits. Results: Daily energy intake for all subjects was 5020 ± 1753 kcal during visit 1 and 4855 ± 1615 kcal during visit 2. There were no significant associations between energy intake and body weight, body mass index, or percentage body fat while subjects used the vending machines, which indicates that intake was not driven by body size or need. Despite overconsumption (%WMEN = 181 ± 57%), the reproducibility of intake between visits, whether expressed as daily energy intake (ICC = 0.90), %WMEN (ICC = 0.86), weight of food consumed (ICC = 0.87), or fat intake (g/d; ICC = 0.87), was highly significant (P < 0.0001). Conclusion: Although ad libitum energy intake exceeded %WMEN, the within-person reliability of this intake across multiple visits was high, which makes this a reproducible method for the measurement of ad libitum intake in subjects who reside in a research unit. This trial was registered at clinicaltrials.gov as NCT00342732. PMID:19923376
Junquera, Concepción; Martínez-Ciriano, Carmen; Castiella, Tomás; Serrano, Pedro; Azanza, María Jesús; Ramón y Cajal Junquera, Santiago
2007-01-01
Abstract Santiago Ramón y Cajal discovered a new type of cell related to the myenteric plexus and also to the smooth muscle cells of the circular muscle layer of the intestine. Based on their morphology, relationships and staining characteristics, he considered these cells as primitive neurons. One century later, despite major improvements in cell biology, the interstitial cells of Cajal (ICCs) are still controversial for many researchers. The aim of study was to perform an immunohistochemical and ultrastructural characterization of the ICCs in the rabbit duo-denum. We have found interstitial cells that are positive for c-Kit, CD34 and nestin and are also positive for Ki67 protein, tightly associated with somatic cell proliferation. By means of electron microscopy, we describe ICCs around enteric ganglia. They present triangular or spindle forms and a very voluminous nucleus with scarce per-inuclear chromatin surrounded by a thin perinuclear cytoplasm that expands with long cytoplasmic processes. ICC processes penetrate among the smooth muscle cells and couple with the processes of other ICCs located in the connective tissue of the circular muscle layer and establish a three-dimensional network. Intercellular con-tacts by means of gap-like junctions are frequent. ICCs also establish gap-like junctions with smooth muscle cells. We also observe a population of interstitial cells of stellate morphology in the connective tissue that sur-rounds the muscle bundles in the circular muscle layer, usually close to nervous trunks. These cells establish different types of contacts with the muscle cells around them. In addition, the presence of a single cilium show-ing a structure 9 + 0 in an ICC is demonstrated for the first time. In conclusion, we report positive staining c-kit, CD34, nestin and Ki 67. ICCs fulfilled the usual transmission electron microscopy (TEM) criteria. A new ultrastructural characteristic of at least some ICCs is demonstrated: the presence of a single cilium. Some populations of ICCs in the rabbit duodenum present certain immunohistochemical and ultrastructural characteristics that often are present in progenitor cells. PMID:17760839
Informed Consent Conversations and Documents: A Quantitative Comparison
Koyfman, Shlomo A.; Reddy, Chandana A.; Hizlan, Sabahat; Leek, Angela C.; Kodish, Eric
2015-01-01
Background Informed consent for clinical research includes two components: informed consent documents (ICD) and informed consent conversations (ICC). Readability software has been used to help simplify the language of the ICD, but rarely employed to assess the language during the ICC, which may influence the quality of informed consent. This analysis was completed to determine if length and reading levels of transcribed ICCs are lower than their corresponding ICDs for selected clinical trials, and to assess whether investigator experience affected use of simpler language and comprehensiveness. Methods Prospective study where ICCs were audio-recorded at 6 institutions when families were offered participation in pediatric phase I oncology trials. Word count, Flesch-Kincaid Grade Level (FKGL) and Flesch Reading Ease Score (FRES) of ICCs were compared to corresponding ICDs, including the frequency that investigators addressed 8 pre-specified critical consent elements during the ICC. Results Sixty-nine unique physician/protocol pairs were identified. Overall, ICCs contained fewer words (4,677 vs. 6,364; p=0.0016), had lower FKGL (6 vs. 9.7; p=<0.0001) and higher FRES (77.8 vs. 56.7; p<0.0001) than their respective ICDs, but were more likely to omit critical consent elements, such as voluntariness (55%) and dose limiting toxicities (26%). Years of investigator experience was not correlated with reliably covering critical elements or decreased linguistic complexity. Conclusions Clinicians use more understandable language during ICCs than the corresponding ICD, but less reliably cover elements critical to fully informed consent. Focused efforts at providing communication training for clinician-investigators should be done to optimize the synergy between the ICD and conversation. PMID:26505269
Xu, Zhe; Chen, Sisi; Yang, Chun; Huang, Shenghai; Shen, Meixiao; Wang, Yuanyuan
2018-01-01
To investigate the repeatability and reproducibility of mapping the entire corneal thickness using spectral domain optical coherence tomography (SD-OCT). Thirty normal eyes, 30 post-laser in situ keratomileusis (LASIK) surgery eyes, and 30 keratoconus eyes were analyzed. A custom-built long scan depth SD-OCT device was used to obtain entire corneal images. Ten-millimeter-diameter corneal thickness maps were generated by an automated segmentation algorithm. Intraclass correlation coefficients of repeatability (ICC1) and reproducibility (ICC2), and coefficients of repeatability (CoR1) and reproducibility (CoR2), were calculated to quantify the precision and accuracy of corneal pachymetry measurements using the Bland-Altman method. For SD-OCT measurements in healthy subjects, CoR1 and CoR2 were less than 5.00 and 5.53 μm. ICC1 and ICC2 were more than 0.997 and 0.996. For SD-OCT measurements in LASIK patients, CoR1 and CoR2 were less than 5.09 and 5.34 μm. ICC1 and ICC2 were more than 0.997 and 0.996. For SD-OCT measurements in keratoconus patients, CoR1 and CoR2 were less than 11.57 and 10.92 μm. ICC1 and ICC2 were more than 0.995 and 0.996. The measurements of corneal pachymetric mapping by long scan depth SD-OCT can be assessed over the entire corneal area with good repeatability and reproducibility. © 2017 S. Karger AG, Basel.
Tamada, Hiromi; Kiyama, Hiroshi
2015-01-01
Interstitial cells of Cajal (ICC) are mesenchymal cells that are distributed along the gastrointestinal tract and function as pacemaker cells or intermediary cells between nerves and smooth muscle cells. ICC express a receptor tyrosine kinase c-Kit, which is an established marker for ICC. The c-kit gene is allelic with the murine white-spotting locus (W), and some ICC subsets were reported to be missing in heterozygous mutant W/Wv mice carrying W and Wv mutated alleles. In this study, the characterization of interstitial cells in the subserosal layer of W/Wv mice was analyzed by immunohistochemistry and electron microscopy. In the proximal and distal colon of W/Wv mutant mice, no c-Kit-positive cells were detected in the subserosal layer by immunohistochemistry. By electron microscopy, the interstitial cells, which were characterized by the existence of caveolae, abundant mitochondria and gap junctions, were observed in the W/Wv mutant colon. The morphological characteristics were comparable to those of the multipolar c-Kit positive ICC seen in the subserosa of proximal and distal colon of wild-type mice. Fibroblasts were also located in the same layers, but the morphology of the fibroblasts was distinguishable from that of ICC in wild type mice or of ICC-like cells in W/Wv mutant mice. Collectively, it is concluded that c-Kit-negative interstitial cells showing a typical ICC ultrastructure exist in the proximal and distal colon of W/Wv mutant mice. PMID:26727725
Tamada, Hiromi; Kiyama, Hiroshi
2015-01-01
Interstitial cells of Cajal (ICC) are mesenchymal cells that are distributed along the gastrointestinal tract and function as pacemaker cells or intermediary cells between nerves and smooth muscle cells. ICC express a receptor tyrosine kinase c-Kit, which is an established marker for ICC. The c-kit gene is allelic with the murine white-spotting locus (W), and some ICC subsets were reported to be missing in heterozygous mutant W/W(v) mice carrying W and W(v) mutated alleles. In this study, the characterization of interstitial cells in the subserosal layer of W/W(v) mice was analyzed by immunohistochemistry and electron microscopy. In the proximal and distal colon of W/W(v) mutant mice, no c-Kit-positive cells were detected in the subserosal layer by immunohistochemistry. By electron microscopy, the interstitial cells, which were characterized by the existence of caveolae, abundant mitochondria and gap junctions, were observed in the W/W(v) mutant colon. The morphological characteristics were comparable to those of the multipolar c-Kit positive ICC seen in the subserosa of proximal and distal colon of wild-type mice. Fibroblasts were also located in the same layers, but the morphology of the fibroblasts was distinguishable from that of ICC in wild type mice or of ICC-like cells in W/W(v) mutant mice. Collectively, it is concluded that c-Kit-negative interstitial cells showing a typical ICC ultrastructure exist in the proximal and distal colon of W/W(v) mutant mice.
Tamada, Hiromi; Kiyama, Hiroshi
2015-01-01
Interstitial cells of Cajal (ICC) are mesenchymal cells that are distributed along the gastrointestinal tract and function as pacemaker cells or intermediary cells between nerves and smooth muscle cells. ICC express a receptor tyrosine kinase c-Kit, which is an established marker for ICC. The c-kit gene is allelic with the murine white-spotting locus (W), and some ICC subsets were reported to be missing in heterozygous mutant W/Wv mice carrying W and Wv mutated alleles. In this study, the characterization of interstitial cells in the subserosal layer of W/Wv mice was analyzed by immunohistochemistry and electron microscopy. In the proximal and distal colon of W/Wv mutant mice, no c-Kit-positive cells were detected in the subserosal layer by immunohistochemistry. By electron microscopy, the interstitial cells, which were characterized by the existence of caveolae, abundant mitochondria and gap junctions, were observed in the W/Wv mutant colon.The morphological characteristics were comparable to those of the multipolar c-Kit positive ICC seen in the subserosa of proximal and distal colon of wild-type mice. Fibroblasts were also located in the same layers,but the morphology of the fibroblasts was distinguishable from that of ICC in wild type mice or of ICC-like cells in W/Wv mutant mice. Collectively, it is concluded that c-Kit-negative interstitial cells showing a typical ICC ultrastructure exist in the proximal and distal colon of W/Wv mutant mice.
Westine, Carl D; Spybrook, Jessaca; Taylor, Joseph A
2013-12-01
Prior research has focused primarily on empirically estimating design parameters for cluster-randomized trials (CRTs) of mathematics and reading achievement. Little is known about how design parameters compare across other educational outcomes. This article presents empirical estimates of design parameters that can be used to appropriately power CRTs in science education and compares them to estimates using mathematics and reading. Estimates of intraclass correlations (ICCs) are computed for unconditional two-level (students in schools) and three-level (students in schools in districts) hierarchical linear models of science achievement. Relevant student- and school-level pretest and demographic covariates are then considered, and estimates of variance explained are computed. Subjects: Five consecutive years of Texas student-level data for Grades 5, 8, 10, and 11. Science, mathematics, and reading achievement raw scores as measured by the Texas Assessment of Knowledge and Skills. Results: Findings show that ICCs in science range from .172 to .196 across grades and are generally higher than comparable statistics in mathematics, .163-.172, and reading, .099-.156. When available, a 1-year lagged student-level science pretest explains the most variability in the outcome. The 1-year lagged school-level science pretest is the best alternative in the absence of a 1-year lagged student-level science pretest. Science educational researchers should utilize design parameters derived from science achievement outcomes. © The Author(s) 2014.
Kim, Jooseong; Lagravére, Manuel O
2016-01-01
The aim of this study was to compare the accuracy of Bolton analysis obtained from digital models scanned with the Ortho Insight three-dimensional (3D) laser scanner system to those obtained from cone-beam computed tomography (CBCT) images and traditional plaster models. CBCT scans and plaster models were obtained from 50 patients. Plaster models were scanned using the Ortho Insight 3D laser scanner; Bolton ratios were calculated with its software. CBCT scans were imported and analyzed using AVIZO software. Plaster models were measured with a digital caliper. Data were analyzed with descriptive statistics and the intraclass correlation coefficient (ICC). Anterior and overall Bolton ratios obtained by the three different modalities exhibited excellent agreement (> 0.970). The mean differences between the scanned digital models and physical models and between the CBCT images and scanned digital models for overall Bolton ratios were 0.41 ± 0.305% and 0.45 ± 0.456%, respectively; for anterior Bolton ratios, 0.59 ± 0.520% and 1.01 ± 0.780%, respectively. ICC results showed that intraexaminer error reliability was generally excellent (> 0.858 for all three diagnostic modalities), with < 1.45% discrepancy in the Bolton analysis. Laser scanned digital models are highly accurate compared to physical models and CBCT scans for assessing the spatial relationships of dental arches for orthodontic diagnosis.
Lopez, Mandi J; Davis, Kechia M; Jeffrey-Borger, Susan L; Markel, Mark D; Rettenmund, Christy
2009-12-01
To determine interobserver repeatability of measurements on computed tomography (CT) images of lax canine hip joints at different ages and in the presence of degenerative joint disease at maturity. Longitudinal observational investigation. Sibling crossbreed hounds. Pelvic CT was performed at 20, 24, 32, 48, 68, and 104 weeks of age. Measures were performed on 3 contiguous two-dimensional (2D) transverse CT images of both hips at each time point by 3 investigators. Center-edge angle (CEA), horizontal toit externe angle (HTEA), ventral (VASA), dorsal (DASA), and horizontal (HASA) acetabular sector angles, acetabular index (AI), and percent femoral head coverage (CPC) were measured. Interobserver repeatability was quantified with the intraclass correlation coefficient (ICC). Satisfactory repeatability was considered when ICC >or=0.75. DASA, CEA, and CPC were repeatable in all age groups. HASA and HTEA were repeatable for all but 1 time point. At 20 weeks of age, all measures but AI were repeatable, and at 104 weeks of age, DASA, CEA, CPC, and HASA were repeatable. Measures were repeatable in hips with and without degenerative changes with the exceptions of AI and HASA in normal hips and VASA and HTEA in osteoarthritic hips. Most 2D CT measurements examined were repeatable regardless of age or joint disease. Two-dimensional CT measures may augment current techniques for assessing joint changes in lax canine hips.
2000-03-21
KENNEDY SPACE CENTER, FLA. -- At Launch Pad 39A, the payload canister with the SPACEHAB Double Module and Integrated Cargo Carrier (ICC) inside is lifted up the Rotating Service Structure toward the Payload Changeout Room, an environmentally controlled facility supporting cargo delivery to the pad and vertical installation in the orbiter cargo bay. The primary payloads on mission STS-101, the module and ICC contain internal logistics and resupply cargo for restoring full redundancy to the International Space Station power system in preparation for the arrival of the next pressurized module, the Russian-built Zvezda. The payloads will be transferred to Space Shuttle Atlantis after Atlantis rolls out to the pad. Launch of Atlantis on mission STS-101 is scheduled no earlier than April 17, 2000
2000-03-21
KENNEDY SPACE CENTER, FLA. -- At Launch Pad 39A, the payload canister with the SPACEHAB Double Module and Integrated Cargo Carrier (ICC) inside is lifted up the Rotating Service Structure toward the Payload Changeout Room, an environmentally controlled facility supporting cargo delivery to the pad and vertical installation in the orbiter cargo bay. The primary payloads on mission STS-101, the module and ICC contain internal logistics and resupply cargo for restoring full redundancy to the International Space Station power system in preparation for the arrival of the next pressurized module, the Russian-built Zvezda. The payloads will be transferred to Space Shuttle Atlantis after Atlantis rolls out to the pad. Launch of Atlantis on mission STS-101 is scheduled no earlier than April 17, 2000
ERIC Educational Resources Information Center
Brese, Falk; Jung, Michael; Mirazchiyski, Plamen; Schulz, Wolfram; Zuehlke, Olaf
2011-01-01
This supplement contains documentation on the explicit and implicit stratification variables included in the International Civic and Citizenship Education Study (ICCS) 2009 data files. The explicit strata are smaller sampling frames, created from the national sampling frames, from which national samples of schools were drawn. The implicit strata…
Schneebeli, Alessandro; Egloff, Michele; Giampietro, Amelia; Clijsen, Ron; Barbero, Marco
2014-04-01
To examine intra- and interrater reliability of thickness and cross-sectional area (CSA) measurements of the supraspinatus muscle using rehabilitative ultrasound imaging (RUSI). Two physical therapists acquired b-mode images of the supraspinatus muscles in twenty-five healthy subjects. Thickness and CSA were measured. Intra- and interrater reliability were examined. Intrarater reliability for thickness was high, (ICC1.1 0.91) for rater 1 and (ICC1.1 0.92) for rater 2. Intrarater reliability for CSA was also high, (ICC1.1 0.90) for rater 1 and (ICC1.1 0.85) for rater 2. Interrater reliability for the thickness was high, (ICC3.1 0.86). For CSA, interrater reliability was moderate, (ICC3.1 0.70). Supraspinatus muscle thickness and CSA can be reliably measured by physical therapists in healthy subjects. These findings confirm that RUSI has an interesting potential for physiotherapy clinical practice, especially to assess morphometric changes in skeletal muscles. Further research is needed in subjects with shoulder disorders. Copyright © 2013 Elsevier Ltd. All rights reserved.
Involvement of mitochondrial Na+–Ca2+ exchange in intestinal pacemaking activity
Kim, Byung Joo; Jun, Jae Yeoul; So, Insuk; Kim, Ki Whan
2006-01-01
AIM: Interstitial cells of Cajal (ICCs) are the pacemaker cells that generate slow waves in the gastrointestinal (GI) tract. We have aimed to investigate the involvement of mitochondrial Na+-Ca2+ exchange in intestinal pacemaking activity in cultured interstitial cells of Cajal. METHODS: Enzymatic digestions were used to dissociate ICCs from the small intestine of a mouse. The whole-cell patch-clamp configuration was used to record membrane currents (voltage clamp) and potentials (current clamp) from cultured ICCs. RESULTS: Clonazepam and CGP37157 inhibited the pacemaking activity of ICCs in a dose-dependent manner. Clonazepam from 20 to 60 µmol/L and CGP37157 from 10 to 30 µmol/L effectively inhibited Ca2+ efflux from mitochondria in pacemaking activity of ICCs. The IC50s of clonazepam and CGP37157 were 37.1 and 18.2 µmol/L, respectively. The addition of 20 µmol/L NiCl2 to the internal solution caused a “wax and wane” phenomenon of pacemaking activity of ICCs. CONCLUSION: These results suggest that mitochondrial Na+-Ca2+ exchange has an important role in intestinal pacemaking activity. PMID:16521198
Forty-Year Trends in Cholangiocarcinoma Incidence in the U.S.: Intrahepatic Disease on the Rise.
Saha, Supriya K; Zhu, Andrew X; Fuchs, Charles S; Brooks, Gabriel A
2016-05-01
Challenges in the diagnosis and classification of cholangiocarcinoma have made it difficult to quantify the true incidence of this highly aggressive malignancy. We analyzed the Surveillance, Epidemiology, and End Results data to assess long-term trends in the age-standardized incidence of intrahepatic and extrahepatic cholangiocarcinoma between 1973 and 2012, correcting for systematic coding errors. Because intrahepatic cholangiocarcinoma (ICC) may frequently be misdiagnosed as cancer of unknown primary (CUP), we also analyzed trends in the incidence of CUP. Between 1973 and 2012, the reported U.S. incidence of ICC increased from 0.44 to 1.18 cases per 100,000, representing an annual percentage change (APC) of 2.30%; this trend has accelerated during the past decade to an APC of 4.36%. The incidence of extrahepatic cholangiocarcinoma increased modestly from 0.95 to 1.02 per 100,000 during the 40-year period (APC, 0.14%). The incidence of CUP with histologic features potentially consistent with cholangiocarcinoma decreased by 51% between 1973 and 2012 (APC, -1.87%), whereas the incidence of CUP with squamous or nonepithelial histologic features increased modestly (APC, 0.42%). The recognized incidence of ICC in the U.S. continues to rise, whereas the incidence of ECC is stable. The incidence of CUP has fallen dramatically during the same time period. Clinical distinctions between cholangiocarcinoma (particularly intrahepatic cholangiocarcinoma [ICC]) and cancer of unknown primary (CUP) can be challenging. Recent discoveries have identified recurrent and potentially targetable genomic abnormalities in ICC, highlighting the importance of improving diagnosis. This study demonstrates that the incidence of ICC is increasing in the U.S., whereas the incidence of extrahepatic cholangiocarcinoma is stable. Concomitantly, the incidence of CUP has declined dramatically, suggesting that improved distinction between ICC and CUP may be a major driver of the increasing recognized incidence of ICC. The increasing incidence of ICC warrants further study of prevention and treatment approaches. ©AlphaMed Press.
Castel, Anne-Laure; Menet, Aymeric; Ennezat, Pierre-Vladimir; Delelis, François; Le Goffic, Caroline; Binda, Camille; Guerbaai, Raphaëlle-Ashley; Levy, Franck; Graux, Pierre; Tribouilloy, Christophe; Maréchaux, Sylvestre
2016-01-01
Speckle tracking can be used to measure left ventricular global longitudinal strain (GLS). To study the effect of speckle tracking software product upgrades on GLS values and intervendor consistency. Subjects (patients or healthy volunteers) underwent systematic echocardiography with equipment from Philips and GE, without a change in their position. Off-line post-processing for GLS assessment was performed with the former and most recent upgrades from these two vendors (Philips QLAB 9.0 and 10.2; GE EchoPAC 12.1 and 13.1.1). GLS was obtained in three myocardial layers with EchoPAC 13.1.1. Intersoftware and intervendor consistency was assessed. Interobserver variability was tested in a subset of patients. Among 73 subjects (65 patients and 8 healthy volunteers), absolute values of GLS were higher with QLAB 10.2 compared with 9.0 (intraclass correlation coefficient [ICC]: 0.88; bias: 2.2%). Agreement between EchoPAC 13.1.1 and 12.1 varied by myocardial layer (13.1.1 only): midwall (ICC: 0.95; bias: -1.1%), endocardium (ICC: 0.93; bias: 1.6%) and epicardial (ICC: 0.80; bias: -3.3%). Although GLS was comparable for QLAB 9.0 versus EchoPAC 12.1 (ICC: 0.95; bias: 0.5%), the agreement was lower between QLAB 10.2 and EchoPAC 13.1.1 endocardial (ICC: 0.91; bias: 1.1%), midwall (ICC: 0.73; bias: 3.9%) and epicardial (ICC: 0.54; bias: 6.0%). Interobserver variability of all software products in a subset of 20 patients was excellent (ICC: 0.97-0.99; bias: -0.8 to 1.0%). Upgrades of speckle tracking software may be associated with significant changes in GLS values, which could affect intersoftware and intervendor consistency. This finding has important clinical implications for the longitudinal follow-up of patients with speckle tracking echocardiography. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Clustering of Ca2+ transients in interstitial cells of Cajal defines slow wave duration
Drumm, Bernard T.; Hennig, Grant W.; Battersby, Matthew J.; Sung, Tae Sik
2017-01-01
Interstitial cells of Cajal (ICC) in the myenteric plexus region (ICC-MY) of the small intestine are pacemakers that generate rhythmic depolarizations known as slow waves. Slow waves depend on activation of Ca2+-activated Cl− channels (ANO1) in ICC, propagate actively within networks of ICC-MY, and conduct to smooth muscle cells where they generate action potentials and phasic contractions. Thus, mechanisms of Ca2+ regulation in ICC are fundamental to the motor patterns of the bowel. Here, we characterize the nature of Ca2+ transients in ICC-MY within intact muscles, using mice expressing a genetically encoded Ca2+ sensor, GCaMP3, in ICC. Ca2+ transients in ICC-MY display a complex firing pattern caused by localized Ca2+ release events arising from multiple sites in cell somata and processes. Ca2+ transients are clustered within the time course of slow waves but fire asynchronously during these clusters. The durations of Ca2+ transient clusters (CTCs) correspond to slow wave durations (plateau phase). Simultaneous imaging and intracellular electrical recordings revealed that the upstroke depolarization of slow waves precedes clusters of Ca2+ transients. Summation of CTCs results in relatively uniform Ca2+ responses from one slow wave to another. These Ca2+ transients are caused by Ca2+ release from intracellular stores and depend on ryanodine receptors as well as amplification from IP3 receptors. Reduced extracellular Ca2+ concentrations and T-type Ca2+ channel blockers decreased the number of firing sites and firing probability of Ca2+ transients. In summary, the fundamental electrical events of small intestinal muscles generated by ICC-MY depend on asynchronous firing of Ca2+ transients from multiple intracellular release sites. These events are organized into clusters by Ca2+ influx through T-type Ca2+ channels to sustain activation of ANO1 channels and generate the plateau phase of slow waves. PMID:28592421
Deng, Jingjing; Yang, Shu; Yuan, Qing; Chen, Yuzhong; Li, Dandan; Sun, Haimei; Tan, Xinghua; Zhang, Fuchun; Zhou, Deshan
2017-01-01
Acupuncture is a therapy effective in treating postoperative ileus (POI); its underlying mechanisms remain unclear. MicroRNAs (miRNAs) participate in inflammation and injury to the interstitial cells of Cajal (ICCs), both of which are considered to be contributors to POI. C-kit, encoding KIT, a specific marker of ICCs, is predicted to be targeted by miR-19a, an inflammation-related miRNA. Therefore, we investigated a possible link between inflammation, miR-19a, and ICCs in POI, as well as the mechanism by which these factors are affected by acupuncture. The effects of acupuncture on POI were assessed in patients after colorectal resection and in colocolic anastomosis mice. Immunofluorescence staining demonstrated that KIT[Formula: see text]/ano1[Formula: see text] ICCs dramatically decreased around the colonic incision in mice, which was negatively correlated with the pronounced increase in macrophage. However, this decrease was not due to apoptosis. IL-6R was expressed in ICCs, and IL-6 level was significantly increased, as measured by ELISA, in accompaniment with high miR-19a expression. The increase in IL-6 and miR-19a levels was negatively correlated with the decrease in KIT[Formula: see text]/ano1[Formula: see text] ICCs. A luciferase reporter assay demonstrated that miR-19a directly targeted C-kit, indicating that miR-19a caused ICC damage. Interestingly, acupuncture inhibited macrophage activation, IL-6 release, and miR-19a upregulation, while promoting KIT and ano1 restoration in ICCs. High serum miR-19a level in patients after colorectal resection was also reduced by acupuncture. Conclusively, the IL-6 released by macrophages during gastrointestinal surgery upregulated miR-19a, which downregulated KIT in ICCs and finally resulted in POI. Acupuncture can interfere with the "IL-6-miR-19a-KIT" axis, suggesting that it may be a therapeutic mechanism that works against POI.
Camera-tracking gaming control device for evaluation of active wrist flexion and extension.
Shefer Eini, Dalit; Ratzon, Navah Z; Rizzo, Albert A; Yeh, Shih-Ching; Lange, Belinda; Yaffe, Batia; Daich, Alexander; Weiss, Patrice L; Kizony, Rachel
Cross sectional. Measuring wrist range of motion (ROM) is an essential procedure in hand therapy clinics. To test the reliability and validity of a dynamic ROM assessment, the Camera Wrist Tracker (CWT). Wrist flexion and extension ROM of 15 patients with distal radius fractures and 15 matched controls were assessed with the CWT and with a universal goniometer. One-way model intraclass correlation coefficient analysis indicated high test-retest reliability for extension (ICC = 0.92) and moderate reliability for flexion (ICC = 0.49). Standard error for extension was 2.45° and for flexion was 4.07°. Repeated-measures analysis revealed a significant main effect for group; ROM was greater in the control group (F[1, 28] = 47.35; P < .001). The concurrent validity of the CWT was partially supported. The results indicate that the CWT may provide highly reliable scores for dynamic wrist extension ROM, and moderately reliable scores for flexion, in people recovering from a distal radius fracture. N/A. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.
Reliability of tristimulus colourimetry in the assessment of cutaneous bruise colour.
Scafide, Katherine N; Sheridan, Daniel J; Taylor, Laura A; Hayat, Matthew J
2016-06-01
Bruising is one of the most common types of injury clinicians observe among victims of violence and other trauma patients. However, research has shown commonly used qualitative description of cutaneous bruise colour via the naked eye is subjective and unreliable. No published work has formally evaluated the reliability of tristimulus colourimetry as an alternative for assessing bruise colour, despite its clinical and research applications in accurately assessing skin colour. The purpose of this study was to systematically evaluate the test-retest and inter-observer reliability of tristimulus colourimetry in the assessment of cutaneous bruise colour. Two researchers obtained repeated tristimulus colourimetry measures of cutaneous bruises with participants of diverse skin colour. Measures were obtained using the Minolta CR-400 Chomameter. Commission Internationale d'Eclairage (CIE) L*a*b* colour space was used. Data was analysed using intraclass correlation coefficients (ICC), Cronbach's alpha, and minimal detectable change (MDC) on all three L*a*b* values. The colorimeter demonstrated excellent test-retest or intra-rater reliability (L* ICC=0.999; a* ICC=0.973; b* ICC=0.892) and inter-rater reliability (L* ICC=0.997; a* ICC=0.976; b* ICC=0.982). With consistent placement, the tristimulus colourimetry is reliable for the objective assessment and documentation of cutaneous bruise colour for purposes of clinical practice and research. Recommendations for use in practice/research are provided. Copyright © 2016 Elsevier Ltd. All rights reserved.
Pruitt, Sandi L; Jeffe, Donna B; Yan, Yan; Schootman, Mario
2012-04-01
Limited psychometric research has examined the reliability of self-reported measures of neighbourhood conditions, the effect of measurement error on associations between neighbourhood conditions and health, and potential differences in the reliabilities between neighbourhood strata (urban vs rural and low vs high poverty). We assessed overall and stratified reliability of self-reported perceived neighbourhood conditions using five scales (social and physical disorder, social control, social cohesion, fear) and four single items (multidimensional neighbouring). We also assessed measurement error-corrected associations of these conditions with self-rated health. Using random-digit dialling, 367 women without breast cancer (matched controls from a larger study) were interviewed twice, 2-3 weeks apart. Test-retest (intraclass correlation coefficients (ICC)/weighted κ) and internal consistency reliability (Cronbach's α) were assessed. Differences in reliability across neighbourhood strata were tested using bootstrap methods. Regression calibration corrected estimates for measurement error. All measures demonstrated satisfactory internal consistency (α ≥ 0.70) and either moderate (ICC/κ=0.41-0.60) or substantial (ICC/κ=0.61-0.80) test-retest reliability in the full sample. Internal consistency did not differ by neighbourhood strata. Test-retest reliability was significantly lower among rural (vs urban) residents for two scales (social control, physical disorder) and two multidimensional neighbouring items; test-retest reliability was higher for physical disorder and lower for one multidimensional neighbouring item among the high (vs low) poverty strata. After measurement error correction, the magnitude of associations between neighbourhood conditions and self-rated health were larger, particularly in the rural population. Research is needed to develop and test reliable measures of perceived neighbourhood conditions relevant to the health of rural populations.
Does pyogenic liver abscess increase the risk of delayed-onset primary liver cancer?
Chu, Chia-Sheng; Lin, Che-Chen; Peng, Cheng-Yuan; Chuang, Po-Heng; Su, Wen-Pang; Lai, Shih-Wei; Chen, Hsuan-Ju; Chung, Chi-Jung; Lai, Hsueh-Chou
2017-01-01
Abstract Delayed-onset primary liver cancer (PLC) including hepatocellular carcinoma (HCC) and intrahepatic cholangiocarcinoma (ICC) in patients with pyogenic liver abscess (PLA) is not common. The relationship between PLA and delayed-onset PLC is unclear. We investigated the association in a nationwide cohort study. From Taiwan National Health Insurance claims data, a cohort of 17,531 patients with PLA was generated after excluding patients with a history of cancer (n = 2034) and those diagnosed with PLC (n = 572) and other cancers (n = 627) within 1 year of a diagnosis of PLA. An age-, sex-, index year-, and diabetes mellitus (DM)-matched control cohort of 70,124 persons without PLA was selected from the same dataset. Both cohorts were followed up until the end of 2011. The risk of PLC was estimated for both cohorts. The incidence of PLC was nearly 2-fold greater in the PLA group than in the control cohort (29.3 per 10,000 person-years vs. 16.2 per 10,000 person-years). The incidences of HCC and ICC were 1.5- (22.1 per 10,000 person-years vs. 15.0 per 10,000 person-years) and 11-fold greater (6.73 per 10,000 person-years vs. 0.62 per 10,000 person-years), respectively, in the PLA group than in the control cohort. The PLA cohort also had high risks of PLC (adjusted hazard ratio [aHR] = 1.56; 95% confidence interval [CI] = 1.35–1.81), HCC (aHR = 1.34; 95% CI = 1.15–1.57), and ICC (aHR = 6.94; 95% CI = 4.23–11.57). In conclusion, in this nationwide cohort study, PLA increased the risk of delayed-onset PLC. PMID:28834881
Huang, Hongshi; Zhang, Dongxia; Jiang, Yanfang; Yang, Jie; Feng, Tao; Gong, Xi; Wang, Jianquan; Ao, Yingfang
2016-01-01
To translate the English version of Tegner Activity Score into a Simplified-Chinese version (Tegner-C) and evaluate its psychometric properties. Tegner-C was cross-culturally adapted according to established guidelines. The validity and reliability of Tegner-C were assessed in 78 participants, with 19-20 participants in each of the four groups: before anterior cruciate ligament reconstruction (pre-ACLR) group, 2-3 months after ACLR group, 3-12 months after ACLR group, and healthy control group. Each participant was asked to complete the Tegner-C and Chinese version of International Knee Documentation Committee Subjective Knee Form (IKDC-SKF-C) twice, with an interval of 5±2 days. Intra-class correlation coefficient (ICC2, 1) was used to assess the reliability and Spearman's rank correlation was used for construct validity. The ICC2,1 was higher than 0.90 for all groups except in the pre-ACLR group, for which the ICC2,1 was 0.71 (0.41, 0.87) (All with p<0.001). The absolute reliability as evaluated by the smallest detectable change was 0.43, 2.12, 0.89, and 0.44 for the healthy control group, pre-ACLR group, 2-3 months after ACLR group, and 3-12 months after ACLR group, respectively. Neither a ceiling effect nor a floor effect was observed for any group. Significant difference was observed for both Tegner-C and IKDC-SKF-C scores between the control and the other three groups (all with p<0.001), and between pre-ACLR and the 2-3 months after ACLR group (p<0.001). Tegner-C demonstrated comparable psychometric properties to the original English version and thus is reliable and valid for Chinese-speaking patients with ACL injury.
29 CFR 782.8 - Special classes of carriers.
Code of Federal Regulations, 2011 CFR
2011-07-01
... subject to its jurisdiction. (New Pittsburgh Coal Co. v. Hocking Valley Ry. Co., 24 I.C.C. 244; Corona Coal Co. v. Secretary of War, 69 I.C.C. 389; Bunker Coal from Alabama to Gulf Ports, 227 I.C.C. 485.) The intrastate delivery of chandleries, including cordage, canvas, repair parts, wire rope, etc., to...
29 CFR 782.8 - Special classes of carriers.
Code of Federal Regulations, 2010 CFR
2010-07-01
... subject to its jurisdiction. (New Pittsburgh Coal Co. v. Hocking Valley Ry. Co., 24 I.C.C. 244; Corona Coal Co. v. Secretary of War, 69 I.C.C. 389; Bunker Coal from Alabama to Gulf Ports, 227 I.C.C. 485.) The intrastate delivery of chandleries, including cordage, canvas, repair parts, wire rope, etc., to...
ERIC Educational Resources Information Center
Fraillon, Julian; Schulz, Wolfram; Ainley, John
2012-01-01
This report presents findings from the Asian regional module of the International Civic and Citizenship Education Study (ICCS), sponsored by the International Association for the Evaluation of Educational Achievement (IEA). ICCS studied the ways in which young people in lower-secondary schools are prepared to undertake their roles as citizens.…
ERIC Educational Resources Information Center
Kerr, David; Sturman, Linda; Schulz, Wolfram; Burge, Bethan
2010-01-01
The International Civic and Citizenship Education Study (ICCS) studied the ways in which countries prepare their young people to undertake their roles as citizens. ICCS was based on the premise that preparing students for citizenship involves helping them develop relevant knowledge and understanding and form positive attitudes toward being a…
An Approach to Biased Item Identification Using Latent Trait Measurement Theory.
ERIC Educational Resources Information Center
Rudner, Lawrence M.
Because it is a true score model employing item parameters which are independent of the examined sample, item characteristic curve theory (ICC) offers several advantages over classical measurement theory. In this paper an approach to biased item identification using ICC theory is described and applied. The ICC theory approach is attractive in that…
Sekir, U; Yildiz, Y; Hazneci, B; Ors, F; Saka, T; Aydin, T
2008-12-01
In contrast to the single evaluation methods used in the past, the combination of multiple tests allows one to obtain a global assessment of the ankle joint. The aim of this study was to determine the reliability of the different tests in a functional test battery. Twenty-four male recreational athletes with unilateral functional ankle instability (FAI) were recruited for this study. One component of the test battery included five different functional ability tests. These tests included a single limb hopping course, single-legged and triple-legged hop for distance, and six and cross six meter hop for time. The ankle joint position sense and one leg standing test were used for evaluation of proprioception and sensorimotor control. The isokinetic strengths of the ankle invertor and evertor muscles were evaluated at a velocity of 120 degrees /s. The reliability of the test battery was assessed by calculating the intraclass correlation coefficient (ICC). Each subject was tested two times, with an interval of 3-5 days between the test sessions. The ICCs for ankle functional and proprioceptive ability showed high reliability (ICCs ranging from 0.94 to 0.98). Additionally, isokinetic ankle joint inversion and eversion strength measurements represented good to high reliability (ICCs between 0.82 and 0.98). The functional test battery investigated in this study proved to be a reliable tool for the assessment of athletes with functional ankle instability. Therefore, clinicians may obtain reliable information from the functional test battery during the assessment of ankle joint performance in patients with functional ankle instability.
Oyeyemi, Adewale L; Bello, Umar M; Philemon, Saratu T; Aliyu, Habeeb N; Majidadi, Rebecca W; Oyeyemi, Adetoyeje Y
2014-12-01
To investigate the reliability and an aspect of validity of a modified version of the long International Physical Activity Questionnaire (Hausa IPAQ-LF) in Nigeria. Cross-sectional study, examining the reliability and construct validity of the Hausa IPAQ-LF compared with anthropometric and biological variables. Metropolitan Maiduguri, the capital city of Borno State in Nigeria. 180 Nigerian adults (50% women) with a mean age of 35.6 (SD=10.3) years, recruited from neighbourhoods with diverse socioeconomic status and walkability. Domains (domestic physical activity (PA), occupational PA, leisure-time PA, active transportation and sitting time) and intensities of PA (vigorous, moderate and walking) were measured with the Hausa IPAQ-LF on two different occasions, 8 days apart. Outcomes for construct validity were measured body mass index (BMI), systolic blood pressure (SBP) and diastolic blood pressure (DBP). The Hausa IPAQ-LF demonstrated good test-retest reliability (intraclass correlation coefficient, ICC>75) for total PA (ICC=0.79, 95% CI 0.65 to 0.82), occupational PA (ICC=0.77, 95% CI 0.68 to 0.82), active transportation (ICC=0.82, 95% CI 0.75 to 0.87) and vigorous intensity activities (ICC=0.82, 95% CI 0.76 to 0.87). Reliability was substantially higher for total PA (ICC=0.80), occupational PA (ICC=0.78), leisure-time PA (ICC=0.75) and active transportation (ICC=0.80) in men than in women, but domestic PA (ICC=0.38) and sitting time (ICC=0.71) demonstrated more substantial reliability coefficients in women than in men. For the construct validity, domestic PA was significantly related mainly with SBP (r=-0.27) and DBP (r=-0.17), and leisure-time PA and total PA were significantly related only with SBP (r=-0.16) and BMI (r=-0.29), respectively. Similarly, moderate-intensity PA was mainly related with SBP (r=-0.16, p<0.05) and DBP (r=-0.21, p<0.01), but vigorous-intensity PA was only related with BMI (r=-0.11, p<0.05). The modified Hausa IPAQ-LF demonstrated sufficient evidence of test-retest reliability and may be valid for assessing context specific PA behaviours of adults in Nigeria. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
An electrical description of the generation of slow waves in the antrum of the guinea-pig
Edwards, FR; Hirst, GDS
2005-01-01
This paper provides an electrical description of the generation of slow waves in the guinea-pig gastric antrum. A short segment of a circular smooth muscle bundle with an attached network of myenteric interstitial cells of Cajal (ICC-MY) and longitudinal muscle sheet was modelled as three electrical compartments with resistive connexions between the ICC-MY compartment and each of the smooth muscle compartments. The circular smooth muscle layer contains a proportion of intramuscular interstitial cells of Cajal (ICC-IM), responsible for the regenerative component of the slow wave. Hence the equivalent cell representing the circular muscle layer incorporated a mechanism, modelled as a two stage reaction, which produces an intracellular messenger. The first stage of the reaction is proposed to be activated in a voltage-dependent manner as described by Hodgkin and Huxley. A similar mechanism was incorporated into the equivalent cell describing the ICC-MY network. Spontaneous discrete transient depolarizations, termed unitary potentials, are detected in records taken from either bundles of circular smooth muscle containing ICC-IM or from ICC-MY. In the simulation the mean rate of discharge of unitary potentials was allowed to vary with the concentration of messenger according to a conventional dose–effect relationship. Such a mechanism, which describes regenerative potentials generated by the circular muscle layer, also simulated the plateau component of the pacemaker potential in the ICC-MY network. A voltage-sensitive membrane conductance was included in the ICC-MY compartment; this was used to describe the primary component of the pacemaker potential. The model generates a range of membrane potential changes with properties similar to those generated by the three cell types present in the intact tissue. PMID:15613372
The Reliability of a Novel Mobile 3-dimensional Wound Measurement Device.
Anghel, Ersilia L; Kumar, Anagha; Bigham, Thomas E; Maselli, Kathryn M; Steinberg, John S; Evans, Karen K; Kim, Paul J; Attinger, Christopher E
2016-11-01
Objective assessment of wound dimensions is essential for tracking progression and determining treatment effectiveness. A reliability study was designed to establish intrarater and interrater reliability of a novel mobile 3-dimensional wound measurement (3DWM) device. Forty-five wounds were assessed by 2 raters using a 3DWM device to obtain length, width, area, depth, and volume measurements. Wounds were also measured manually, using a disposable ruler and digital planimetry. The intraclass correlation coefficient (ICC) was used to establish intrarater and interrater reliability. High levels of intrarater and interrater agreement were observed for area, length, and width; ICC = 0.998, 0.977, 0.955 and 0.999, 0.997, 0.995, respectively. Moderate levels of intrarater (ICC = 0.888) and interrater (ICC = 0.696) agreement were observed for volume. Lastly, depth yielded an intrarater ICC of 0.360 and an interrater ICC of 0.649. Measures from the 3DWM device were highly correlated with those obtained from scaled photography for length, width, and area (ρ = 0.997, 0.988, 0.997, P < 0.001). The 3DWM device yielded correlations of ρ = 0.990, 0.987, 0.996 with P < 0.001 for length, width, and area when compared to manual measurements. The 3DWM device was found to be highly reliable for measuring wound areas for a range of wound sizes and types as compared to manual measurement and digital planimetry. The depth and therefore volume measurement using the 3DWM device was found to have a lower ICC, but volume ICC alone was moderate. Overall, this device offers a mobile option for objective wound measurement in the clinical setting.
O'Grady, Gregory; Du, Peng; Paskaranandavadivel, Nira; Angeli, Timothy R.; Lammers, Wim JEP; Asirvatham, Samuel J.; Windsor, John A.; Farrugia, Gianrico; Pullan, Andrew J.; Cheng, Leo K.
2012-01-01
Background Gastric slow waves propagate aborally as rings of excitation. Circumferential propagation does not normally occur, except at the pacemaker region. We hypothesized that: i) the unexplained high-velocity, high-amplitude activity associated with the pacemaker region is a consequence of circumferential propagation; ii) rapid, high-amplitude circumferential propagation emerges during gastric dysrhythmias; iii) the driving network conductance might switch between ICC-MP and circular ICC-IM during circumferential propagation; iv) extracellular amplitudes and velocities are correlated. Methods An experimental-theoretical study was performed. HR gastric mapping was performed in pigs during normal activation, pacing and dysrhythmia. Activation profiles, velocities and amplitudes were quantified. ICC pathways were theoretically evaluated in a bidomain model. Extracellular potentials were modelled as a function of membrane potentials. Key Results High-velocity, high-amplitude activation was only recorded in the pacemaker region when circumferential conduction occurred. Circumferential propagation accompanied dysrhythmia in 8/8 experiments, was faster than longitudinal propagation (8.9 vs 6.9 mm/s; p=0.004), and of higher amplitude (739 vs 528 μV; p=0.007). Simulations predicted that ICC-MP could be the driving network during longitudinal propagation, whereas during ectopic pacemaking, ICC-IM could outpace and activate ICC-MP in the circumferential axis. Experimental and modeling data demonstrated a linear relationship between velocities and amplitudes (p<0.001). Conclusions & Inferences The high-velocity and high-amplitude profile of the normal pacemaker region is due to localized circumferential propagation. Rapid circumferential propagation also emerges during a range of gastric dysrhythmias, elevating extracellular amplitudes and organizing transverse wavefronts. One possible explanation for these findings is bidirectional coupling between ICC-MP and circular ICC-IM networks. PMID:22709238
The Reliability of Anthropometric Measurements Used Preoperatively in Aesthetic Breast Surgery.
Isaac, Kathryn V; Murphy, Blake D; Beber, Brett; Brown, Mitchell
2016-04-01
Patient outcomes in aesthetic breast surgery are highly dependent on breast measurements used in preoperative planning. The purpose of this study is to determine the reliability of anthropometric breast measurements. Four raters measured 28 women using 7 measurements: sternal notch to nipple distance (Sn-N), nipple to midline (N-M), nipple to inframammary-fold distance under maximal stretch (N-IMF), breast base width (BW), soft tissue pinch thickness of the upper pole (STPT:UP), STPT at the inframammary fold (STPT:IMF), and anterior pull skin stretch (APSS). Reliability was assessed using intra-class correlation coefficients (ICCs). Inter-rater reliability was excellent for Sn-N, N-M, and BW (ICC = 0.94, 0.90, and 0.76, respectively) and was good for N-IMF (ICC = 0.70). The STPT:UP, STPT:IMF, and APSS measurements were not reliable between raters (ICC < 0.2). Intra-rater reliability was excellent for Sn-N, N-M, and BW for all raters (all ICC > 0.75). The N-IMF intra-rater reliability was excellent in senior raters (ICC > 0.75) and good in junior raters (ICC > 0.6). The STPT:UP, STPT:IMF, and APSS measurements showed fair or poor reliability for most raters (ICC < 0.6). The Sn-N, N-M, and BW measurements are very reliable. Dynamic measurements including APSS, STPT:UP, and STUP:IMF are unreliable. N-IMF is the only reliable dynamic measurement, and its reliability improves with increasing clinical experience. The variable reliability of preoperative measurements must be considered in the planning of aesthetic breast surgery. 4 Diagnostic. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.
Prowse, Ashleigh; Aslaksen, Berit; Kierkegaard, Marie; Furness, James; Gerdhem, Paul; Abbott, Allan
2017-01-18
To investigate the reliability and concurrent validity of the Baseline ® Body Level/Scoliosis meter for adolescent idiopathic scoliosis postural assessment in three anatomical planes. This is an observational reliability and concurrent validity study of adolescent referrals to the Orthopaedic department for scoliosis screening at Karolinska University Hospital, Stockholm, Sweden between March-May 2012. A total of 31 adolescents with idiopathic scoliosis (13.6 ± 0.6 years old) of mild-moderate curvatures (25° ± 12°) were consecutively recruited. Measurement of cervical, thoracic and lumbar curvatures, pelvic and shoulder tilt, and axial thoracic rotation (ATR) were performed by two trained physiotherapists in one day. The intraclass correlation coefficient (ICC) was used to determine the inter-examiner reliability (ICC2,1) and the intra-rater reliability (ICC3,3) of the Baseline ® Body Level/Scoliosis meter. Spearman's correlation analyses were used to estimate concurrent validity between the Baseline ® Body Level/Scoliosis meter and Gold Standard Cobb angles from radiographs and the Orthopaedic Systems Inc. Scoliometer. There was excellent reliability between examiners for thoracic kyphosis (ICC2,1 = 0.94), ATR (ICC2,1 = 0.92) and lumbar lordosis (ICC2,1 = 0.79). There was adequate reliability between examiners for cervical lordosis (ICC2,1 = 0.51), however poor reliability for pelvic and shoulder tilt. Both devices were reproducible in the measurement of ATR when repeated by one examiner (ICC3,3 0.98-1.00). The device had a good correlation with the Scoliometer (rho = 0.78). When compared with Cobb angle from radiographs, there was a moderate correlation for ATR (rho = 0.627). The Baseline ® Body Level/Scoliosis meter provides reliable transverse and sagittal cervical, thoracic and lumbar measurements and valid transverse plan measurements of mild-moderate scoliosis deformity.
User’s Guide for Naval Material Command’s Life Cycle Cost (FLEX) Model.
1982-04-01
MATERIAL COMMANDl’S 3 LIFE CYCLE COST (FLEX) MODEL Icc FoIuhrInomto -- -- P ea eCo tc Pleale Cona, ______ _____-Thims document rc~ ofl 5C72 -lot REPORT...Material Command’s Life Cycle Cost (FLEX) Prep. 4/82 ___ Model ______________ ______________ 7. Author(s) S. Performing Organization Rapt. No. R. Dress (ESA...WANG 1I. Abstract (Limit: 200 words) The FLEX-9E life cycle cost comp~uter model is a user-oriented methodology accommodating most cost structures and
Terada, Maiko; Horisawa, Kenichi; Miura, Shizuka; Takashima, Yasuo; Ohkawa, Yasuyuki; Sekiya, Sayaka; Matsuda-Ito, Kanae; Suzuki, Atsushi
2016-01-01
Intrahepatic cholangiocarcinoma (ICC) is a malignant epithelial neoplasm composed of cells resembling cholangiocytes that line the intrahepatic bile ducts in portal areas of the hepatic lobule. Although ICC has been defined as a tumor arising from cholangiocyte transformation, recent evidence from genetic lineage-tracing experiments has indicated that hepatocytes can be a cellular origin of ICC by directly changing their fate to that of biliary lineage cells. Notch signaling has been identified as an essential factor for hepatocyte conversion into biliary lineage cells at the onset of ICC. However, the mechanisms underlying Notch signal activation in hepatocytes remain unclear. Here, using a mouse model of ICC, we found that hepatic macrophages called Kupffer cells transiently congregate around the central veins in the liver and express the Notch ligand Jagged-1 coincident with Notch activation in pericentral hepatocytes. Depletion of Kupffer cells prevents the Notch-mediated cell-fate conversion of hepatocytes to biliary lineage cells, inducing hepatocyte apoptosis and increasing mortality in mice. These findings will be useful for uncovering the pathogenic mechanism of ICC and developing prevenient and therapeutic strategies for this refractory disease. PMID:27698452
Al-Adra, D P; Gill, R S; Axford, S J; Shi, X; Kneteman, N; Liau, S-S
2015-01-01
Radioembolization with yttrium-90 microspheres offers an alternative treatment option for patients with unresectable intrahepatic cholangiocarcinoma (ICC). However, the rarity and heterogeneity of ICC makes it difficult to draw firm conclusions about treatment efficacy. Therefore, the goal of the current study is to systematically review the existing literature surrounding treatment of unresectable ICCs with yttrium-90 microspheres and provide a comprehensive review of the current experience and clinical outcome of this treatment modality. We performed a comprehensive search of electronic databases for ICC treatment and identified 12 studies with relevant data regarding radioembolization therapy with yttrium-90 microspheres. Based on pooled analysis, the overall weighted median survival was 15.5 months. Tumour response based on radiological studies demonstrated a partial response in 28% and stable disease in 54% of patients at three months. Seven patients were able to be downstaged to surgical resection. The complication profile of radioembolization is similar to that of other intra-arterial treatment modalities. Overall survival of patients with ICC after treatment with yttrium-90 microspheres is higher than historical survival rates and shows similar survival to those patients treated with systemic chemotherapy and/or trans-arterial chemoembolization therapy. Therefore, the use of yttrium-90 microspheres should be considered in the list of available treatment options for ICC. However, future randomized trials comparing systemic chemotherapy, TACE and local radiation will be required to identify the optimal treatment modality for unresectable ICC. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.
Hayashi, Teruo; Lewis, Abasha; Hayashi, Eri; Betenbaugh, Michael J.; Su, Tsung-Ping
2011-01-01
Molecular chaperones localized at the endoplasmic reticulum (ER) lumen constitutively or cellular stress-dependently associate with a variety of proteins to promote their proper folding or to inhibit protein misfolding. ER chaperones preferentially form large complexes with co-chaperones and/or misfolded proteins in a highly crowded cellular environment that often hampers their detection by immunocytochemistry (ICC). This study establishes an antigen retrieval (AR) protocol to improve the ICC detection of ER chaperones in cultured cells using widely available antibodies against synthetic peptides. Among ten different antigen retrieval/fixation conditions, only the AR with Tris-HCl (pH 9.5) containing 6 M urea (80 °C for 10 min) significantly improved the ICC detection of the novel ER chaperone sigma-1 receptor (Sig-1R) in Chinese hamster ovary cells. Extended fixation with 4% paraformaldehyde for 1 hr effectively preserved the morphology of the ER under the AR condition. This method greatly enhanced the signal-to-noise ratio in Sig-1R ICC, thus allowing for semi-quantitative detection of protein upregulation under ER stress. The AR similarly improved the ICC detection of a series of other major ER chaperones, including BiP/GRP78, GRP94, calnexin, calreticulin, ERp57, protein disulfide isomerase, and cyclophilin B. The improved ICC methodology using the urea AR at 80°C may improve ICC of ER molecules as well as visualization of ER structure and substructures. PMID:21573736
Omari, Taher I.; Savilampi, Johanna; Kokkinn, Karmen; Schar, Mistyka; Lamvik, Kristin; Doeltgen, Sebastian; Cock, Charles
2016-01-01
Purpose. We evaluated the intra- and interrater agreement and test-retest reliability of analyst derivation of swallow function variables based on repeated high resolution manometry with impedance measurements. Methods. Five subjects swallowed 10 × 10 mL saline on two occasions one week apart producing a database of 100 swallows. Swallows were repeat-analysed by six observers using software. Swallow variables were indicative of contractility, intrabolus pressure, and flow timing. Results. The average intraclass correlation coefficients (ICC) for intra- and interrater comparisons of all variable means showed substantial to excellent agreement (intrarater ICC 0.85–1.00; mean interrater ICC 0.77–1.00). Test-retest results were less reliable. ICC for test-retest comparisons ranged from slight to excellent depending on the class of variable. Contractility variables differed most in terms of test-retest reliability. Amongst contractility variables, UES basal pressure showed excellent test-retest agreement (mean ICC 0.94), measures of UES postrelaxation contractile pressure showed moderate to substantial test-retest agreement (mean Interrater ICC 0.47–0.67), and test-retest agreement of pharyngeal contractile pressure ranged from slight to substantial (mean Interrater ICC 0.15–0.61). Conclusions. Test-retest reliability of HRIM measures depends on the class of variable. Measures of bolus distension pressure and flow timing appear to be more test-retest reliable than measures of contractility. PMID:27190520
Muller, Bart; Hofbauer, Marcus; Rahnemai-Azar, Amir Ata; Wolf, Megan; Araki, Daisuke; Hoshino, Yuichi; Araujo, Paulo; Debski, Richard E; Irrgang, James J; Fu, Freddie H; Musahl, Volker
2016-01-01
The pivot shift test is a commonly used clinical examination by orthopedic surgeons to evaluate knee function following injury. However, the test can only be graded subjectively by the examiner. Therefore, the purpose of this study is to develop software for a computer tablet to quantify anterior translation of the lateral knee compartment during the pivot shift test. Based on the simple image analysis method, software for a computer tablet was developed with the following primary design constraint - the software should be easy to use in a clinical setting and it should not slow down an outpatient visit. Translation of the lateral compartment of the intact knee was 2.0 ± 0.2 mm and for the anterior cruciate ligament-deficient knee was 8.9 ± 0.9 mm (p < 0.001). Intra-tester (ICC range = 0.913 to 0.999) and inter-tester (ICC = 0.949) reliability were excellent for the repeatability assessments. Overall, the average percent error of measuring simulated translation of the lateral knee compartment with the tablet parallel to the monitor increased from 2.8% at 50 cm distance to 7.7% at 200 cm. Deviation from the parallel position of the tablet did not have a significant effect until a tablet angle of 45°. Average percent error during anterior translation of the lateral knee compartment of 6mm was 2.2% compared to 6.2% for 2 mm of translation. The software provides reliable, objective, and quantitative data on translation of the lateral knee compartment during the pivot shift test and meets the design constraints posed by the clinical setting.
Balekian, Alex A; Silvestri, Gerard A; Simkovich, Suzanne M; Mestaz, Peter J; Sanders, Gillian D; Daniel, Jamie; Porcel, Jackie; Gould, Michael K
2013-12-01
Management of pulmonary nodules depends critically on the probability of malignancy. Models to estimate probability have been developed and validated, but most clinicians rely on judgment. The aim of this study was to compare the accuracy of clinical judgment with that of two prediction models. Physician participants reviewed up to five clinical vignettes, selected at random from a larger pool of 35 vignettes, all based on actual patients with lung nodules of known final diagnosis. Vignettes included clinical information and a representative slice from computed tomography. Clinicians estimated the probability of malignancy for each vignette. To examine agreement with models, we calculated intraclass correlation coefficients (ICC) and kappa statistics. To examine accuracy, we compared areas under the receiver operator characteristic curve (AUC). Thirty-six participants completed 179 vignettes, 47% of which described patients with malignant nodules. Agreement between participants and models was fair for the Mayo Clinic model (ICC, 0.37; 95% confidence interval [CI], 0.23-0.50) and moderate for the Veterans Affairs model (ICC, 0.46; 95% CI, 0.34-0.57). There was no difference in accuracy between participants (AUC, 0.70; 95% CI, 0.62-0.77) and the Mayo Clinic model (AUC, 0.71; 95% CI, 0.62-0.80; P = 0.90) or the Veterans Affairs model (AUC, 0.72; 95% CI, 0.64-0.80; P = 0.54). In this vignette-based study, clinical judgment and models appeared to have similar accuracy for lung nodule characterization, but agreement between judgment and the models was modest, suggesting that qualitative and quantitative approaches may provide complementary information.
Barbado, David; Moreside, Janice; Vera-Garcia, Francisco J
2017-03-01
Although unstable seat methodology has been used to assess trunk postural control, the reliability of the variables that characterize it remains unclear. To analyze reliability and learning effect of center of pressure (COP) and kinematic parameters that characterize trunk postural control performance in unstable seating. The relationships between kinematic and COP parameters also were explored. Test-retest reliability design. Biomechanics laboratory setting. Twenty-three healthy male subjects. Participants volunteered to perform 3 sessions at 1-week intervals, each consisting of five 70-second balancing trials. A force platform and a motion capture system were used to measure COP and pelvis, thorax, and spine displacements. Reliability was assessed through standard error of measurement (SEM) and intraclass correlation coefficients (ICC 2,1 ) using 3 methods: (1) comparing the last trial score of each day; (2) comparing the best trial score of each day; and (3) calculating the average of the three last trial scores of each day. Standard deviation and mean velocity were calculated to assess balance performance. Although analyses of variance showed some differences in balance performance between days, these differences were not significant between days 2 and 3. Best result and average methods showed the greatest reliability. Mean velocity of the COP showed high reliability (0.71 < ICC < 0.86; 10.3 < SEM < 13.0), whereas standard deviation only showed a low to moderate reliability (0.37 < ICC < 0.61; 14.5 < SEM < 23.0). Regarding the kinematic variables, only pelvis displacement mean velocity achieved a high reliability using the average method (0.62 < ICC < 0.83; 18.8 < SEM < 23.1). Correlations between COP and kinematics were high only for mean velocity (0.45
2000-03-21
KENNEDY SPACE CENTER, FLA. -- The doors of the payload canister open in the Payload Changeout Room (PCR) at Launch Pad 39A to reveal the SPACEHAB Double Module (bottom) and Integrated Cargo Carrier (ICC). Part of the Rotating Service Structure, the PCR is an environmentally controlled facility supporting cargo delivery to the pad and vertical installation in the orbiter cargo bay. The primary payloads on mission STS-101, the module and ICC contain internal logistics and resupply cargo for restoring full redundancy to the International Space Station power system in preparation for the arrival of the next pressurized module, the Russian-built Zvezda. The payloads will be transferred to Space Shuttle Atlantis after Atlantis rolls out to the pad. Launch of Atlantis on mission STS-101 is scheduled no earlier than April 17, 2000
2000-03-21
KENNEDY SPACE CENTER, FLA. -- The doors of the payload canister open in the Payload Changeout Room (PCR) at Launch Pad 39A to reveal the SPACEHAB Double Module (bottom) and Integrated Cargo Carrier (ICC). Part of the Rotating Service Structure, the PCR is an environmentally controlled facility supporting cargo delivery to the pad and vertical installation in the orbiter cargo bay. The primary payloads on mission STS-101, the module and ICC contain internal logistics and resupply cargo for restoring full redundancy to the International Space Station power system in preparation for the arrival of the next pressurized module, the Russian-built Zvezda. The payloads will be transferred to Space Shuttle Atlantis after Atlantis rolls out to the pad. Launch of Atlantis on mission STS-101 is scheduled no earlier than April 17, 2000
Arensman, Remco M; Pisters, Martijn F; de Man-van Ginkel, Janneke M; Schuurmans, Marieke J; Jette, Alan M; de Bie, Rob A
2016-09-01
Adequate and user-friendly instruments for assessing physical function and disability in older adults are vital for estimating and predicting health care needs in clinical practice. The Late-Life Function and Disability Instrument Computer Adaptive Test (LLFDI-CAT) is a promising instrument for assessing physical function and disability in gerontology research and clinical practice. The aims of this study were: (1) to translate the LLFDI-CAT to the Dutch language and (2) to investigate its validity and reliability in a sample of older adults who spoke Dutch and dwelled in the community. For the assessment of validity of the LLFDI-CAT, a cross-sectional design was used. To assess reliability, measurement of the LLFDI-CAT was repeated in the same sample. The item bank of the LLFDI-CAT was translated with a forward-backward procedure. A sample of 54 older adults completed the LLFDI-CAT, World Health Organization Disability Assessment Schedule 2.0, RAND 36-Item Short-Form Health Survey physical functioning scale (10 items), and 10-Meter Walk Test. The LLFDI-CAT was repeated in 2 to 8 days (mean=4.5 days). Pearson's r and the intraclass correlation coefficient (ICC) (2,1) were calculated to assess validity, group-level reliability, and participant-level reliability. A correlation of .74 for the LLFDI-CAT function scale and the RAND 36-Item Short-Form Health Survey physical functioning scale (10 items) was found. The correlations of the LLFDI-CAT disability scale with the World Health Organization Disability Assessment Schedule 2.0 and the 10-Meter Walk Test were -.57 and -.53, respectively. The ICC (2,1) of the LLFDI-CAT function scale was .84, with a group-level reliability score of .85. The ICC (2,1) of the LLFDI-CAT disability scale was .76, with a group-level reliability score of .81. The high percentage of women in the study and the exclusion of older adults with recent joint replacement or hospitalization limit the generalizability of the results. The Dutch LLFDI-CAT showed strong validity and high reliability when used to assess physical function and disability in older adults dwelling in the community. © 2016 American Physical Therapy Association.
Tyagi, Avishkar; Yeganeh, Omid; Levin, Yakir; Hooker, Jonathan C; Hamilton, Gavin C; Wolfson, Tanya; Gamst, Anthony; Zand, Amir K; Heba, Elhamy; Loomba, Rohit; Schwimmer, Jeffrey; Middleton, Michael S; Sirlin, Claude B
2015-10-01
Determine intra- and inter-examination repeatability of magnitude-based magnetic resonance imaging (MRI-M), complex-based magnetic resonance imaging (MRI-C), and magnetic resonance spectroscopy (MRS) at 3T for estimating hepatic proton density fat fraction (PDFF), and using MRS as a reference, confirm MRI-M and MRI-C accuracy. Twenty-nine overweight and obese pediatric (n = 20) and adult (n = 9) subjects (23 male, 6 female) underwent three same-day 3T MR examinations. In each examination MRI-M, MRI-C, and single-voxel MRS were acquired three times. For each MRI acquisition, hepatic PDFF was estimated at the MRS voxel location. Intra- and inter-examination repeatability were assessed by computing standard deviations (SDs) and intra-class correlation coefficients (ICCs). Aggregate SD was computed for each method as the square root of the average of first repeat variances. MRI-M and MRI-C PDFF estimation accuracy was assessed using linear regression with MRS as a reference. For MRI-M, MRI-C, and MRS acquisitions, respectively, mean intra-examination SDs were 0.25%, 0.42%, and 0.49%; mean intra-examination ICCs were 0.999, 0.997, and 0.995; mean inter-examination SDs were 0.42%, 0.45%, and 0.46%; and inter-examination ICCs were 0.995, 0.992, and 0.990. Aggregate SD for each method was <0.9%. Using MRS as a reference, regression slope, intercept, average bias, and R (2), respectively, for MRI-M were 0.99%, 1.73%, 1.61%, and 0.986, and for MRI-C were 0.96%, 0.43%, 0.40%, and 0.991. MRI-M, MRI-C, and MRS showed high intra- and inter-examination hepatic PDFF estimation repeatability in overweight and obese subjects. Longitudinal hepatic PDFF change >1.8% (twice the maximum aggregate SD) may represent real change rather than measurement imprecision. Further research is needed to assess whether examinations performed on different days or with different MR technologists affect repeatability of MRS voxel placement and MRS-based PDFF measurements.
Tyagi, Avishkar; Yeganeh, Omid; Levin, Yakir; Hooker, Jonathan C.; Hamilton, Gavin C.; Wolfson, Tanya; Gamst, Anthony; Zand, Amir K.; Heba, Elhamy; Loomba, Rohit; Schwimmer, Jeffrey; Middleton, Michael S.; Sirlin, Claude B.
2016-01-01
Purpose Determine intra- and inter-examination repeatability of magnitude-based magnetic resonance imaging (MRI-M), complex-based magnetic resonance imaging (MRI-C), and magnetic resonance spectroscopy (MRS) at 3T for estimating hepatic proton density fat fraction (PDFF), and using MRS as a reference, confirm MRI-M and MRI-C accuracy. Methods Twenty-nine overweight and obese pediatric (n = 20) and adult (n = 9) subjects (23 male, 6 female) underwent three same-day 3T MR examinations. In each examination MRI-M, MRI-C, and single-voxel MRS were acquired three times. For each MRI acquisition, hepatic PDFF was estimated at the MRS voxel location. Intra- and inter-examination repeatability were assessed by computing standard deviations (SDs) and intra-class correlation coefficients (ICCs). Aggregate SD was computed for each method as the square root of the average of first repeat variances. MRI-M and MRI-C PDFF estimation accuracy was assessed using linear regression with MRS as a reference. Results For MRI-M, MRI-C, and MRS acquisitions, respectively, mean intra-examination SDs were 0.25%, 0.42%, and 0.49%; mean intra-examination ICCs were 0.999, 0.997, and 0.995; mean inter-examination SDs were 0.42%, 0.45%, and 0.46%; and inter-examination ICCs were 0.995, 0.992, and 0.990. Aggregate SD for each method was <0.9%. Using MRS as a reference, regression slope, intercept, average bias, and R2, respectively, for MRI-M were 0.99%, 1.73%, 1.61%, and 0.986, and for MRI-C were 0.96%, 0.43%, 0.40%, and 0.991. Conclusion MRI-M, MRI-C, and MRS showed high intra- and inter-examination hepatic PDFF estimation repeatability in overweight and obese subjects. Longitudinal hepatic PDFF change >1.8% (twice the maximum aggregate SD) may represent real change rather than measurement imprecision. Further research is needed to assess whether examinations performed on different days or with different MR technologists affect repeatability of MRS voxel placement and MRS-based PDFF measurements. PMID:26350282
ERIC Educational Resources Information Center
Hua, Zhu; Handford, Michael; Young, Tony Johnstone
2017-01-01
This paper examines how intercultural communication (ICC) and the notion of culture are framed in on-line promotional discourse of higher education (HE) ICC courses. It analyses a specialised corpus comprised of 14,842 words from 43 course websites of master's programmes in ICC in the UK and the US--internationally, the two largest providers of…
Interrater reliability of the mind map assessment rubric in a cohort of medical students.
D'Antoni, Anthony V; Zipp, Genevieve Pinto; Olson, Valerie G
2009-04-28
Learning strategies are thinking tools that students can use to actively acquire information. Examples of learning strategies include mnemonics, charts, and maps. One strategy that may help students master the tsunami of information presented in medical school is the mind map learning strategy. Currently, there is no valid and reliable rubric to grade mind maps and this may contribute to their underutilization in medicine. Because concept maps and mind maps engage learners similarly at a metacognitive level, a valid and reliable concept map assessment scoring system was adapted to form the mind map assessment rubric (MMAR). The MMAR can assess mind map depth based upon concept-links, cross-links, hierarchies, examples, pictures, and colors. The purpose of this study was to examine interrater reliability of the MMAR. This exploratory study was conducted at a US medical school as part of a larger investigation on learning strategies. Sixty-six (N = 66) first-year medical students were given a 394-word text passage followed by a 30-minute presentation on mind mapping. After the presentation, subjects were again given the text passage and instructed to create mind maps based upon the passage. The mind maps were collected and independently scored using the MMAR by 3 examiners. Interrater reliability was measured using the intraclass correlation coefficient (ICC) statistic. Statistics were calculated using SPSS version 12.0 (Chicago, IL). Analysis of the mind maps revealed the following: concept-links ICC = .05 (95% CI, -.42 to .38), cross-links ICC = .58 (95% CI, .37 to .73), hierarchies ICC = .23 (95% CI, -.15 to .50), examples ICC = .53 (95% CI, .29 to .69), pictures ICC = .86 (95% CI, .79 to .91), colors ICC = .73 (95% CI, .59 to .82), and total score ICC = .86 (95% CI, .79 to .91). The high ICC value for total mind map score indicates strong MMAR interrater reliability. Pictures and colors demonstrated moderate to strong interrater reliability. We conclude that the MMAR may be a valid and reliable tool to assess mind maps in medicine. However, further research on the validity and reliability of the MMAR is necessary.
Masood, Mohd; Reidpath, Daniel D
2016-01-07
Measuring the intraclass correlation coefficient (ICC) and design effect (DE) may help to modify the public health interventions for body mass index (BMI), physical activity and diet according to geographic targeting of interventions in different countries. The purpose of this study was to quantify the level of clustering and DE in BMI, physical activity and diet in 56 low-income, middle-income and high-income countries. Cross-sectional study design. Multicountry national survey data. The World Health Survey (WHS), 2003, data were used to examine clustering in BMI, physical activity in metabolic equivalent of task (MET) and diet in fruits and vegetables intake (FVI) from low-income, middle-income and high-income countries. Multistage sampling in the WHS used geographical clusters as primary sampling units (PSU). These PSUs were used as a clustering or grouping variable in this analysis. Multilevel intercept only regression models were used to calculate the ICC and DE for each country. The median ICC (0.039) and median DE (1.82) for BMI were low; however, FVI had a higher median ICC (0.189) and median DE (4.16). For MET, the median ICC was 0.141 and median DE was 4.59. In some countries, however, the ICC and DE for BMI were large. For instance, South Africa had the highest ICC (0.39) and DE (11.9) for BMI, whereas Uruguay had the highest ICC (0.434) for MET and Ethiopia had the highest ICC (0.471) for FVI. This study shows that across a wide range of countries, there was low area level clustering for BMI, whereas MET and FVI showed high area level clustering. These results suggested that the country level clustering effect should be considered in developing preventive approaches for BMI, as well as improving physical activity and healthy diets for each country. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Interrater reliability of the mind map assessment rubric in a cohort of medical students
D'Antoni, Anthony V; Zipp, Genevieve Pinto; Olson, Valerie G
2009-01-01
Background Learning strategies are thinking tools that students can use to actively acquire information. Examples of learning strategies include mnemonics, charts, and maps. One strategy that may help students master the tsunami of information presented in medical school is the mind map learning strategy. Currently, there is no valid and reliable rubric to grade mind maps and this may contribute to their underutilization in medicine. Because concept maps and mind maps engage learners similarly at a metacognitive level, a valid and reliable concept map assessment scoring system was adapted to form the mind map assessment rubric (MMAR). The MMAR can assess mind map depth based upon concept-links, cross-links, hierarchies, examples, pictures, and colors. The purpose of this study was to examine interrater reliability of the MMAR. Methods This exploratory study was conducted at a US medical school as part of a larger investigation on learning strategies. Sixty-six (N = 66) first-year medical students were given a 394-word text passage followed by a 30-minute presentation on mind mapping. After the presentation, subjects were again given the text passage and instructed to create mind maps based upon the passage. The mind maps were collected and independently scored using the MMAR by 3 examiners. Interrater reliability was measured using the intraclass correlation coefficient (ICC) statistic. Statistics were calculated using SPSS version 12.0 (Chicago, IL). Results Analysis of the mind maps revealed the following: concept-links ICC = .05 (95% CI, -.42 to .38), cross-links ICC = .58 (95% CI, .37 to .73), hierarchies ICC = .23 (95% CI, -.15 to .50), examples ICC = .53 (95% CI, .29 to .69), pictures ICC = .86 (95% CI, .79 to .91), colors ICC = .73 (95% CI, .59 to .82), and total score ICC = .86 (95% CI, .79 to .91). Conclusion The high ICC value for total mind map score indicates strong MMAR interrater reliability. Pictures and colors demonstrated moderate to strong interrater reliability. We conclude that the MMAR may be a valid and reliable tool to assess mind maps in medicine. However, further research on the validity and reliability of the MMAR is necessary. PMID:19400964
Pulmonary disease in cystic fibrosis: assessment with chest CT at chest radiography dose levels.
Ernst, Caroline W; Basten, Ines A; Ilsen, Bart; Buls, Nico; Van Gompel, Gert; De Wachter, Elke; Nieboer, Koenraad H; Verhelle, Filip; Malfroot, Anne; Coomans, Danny; De Maeseneer, Michel; de Mey, Johan
2014-11-01
To investigate a computed tomographic (CT) protocol with iterative reconstruction at conventional radiography dose levels for the assessment of structural lung abnormalities in patients with cystic fibrosis ( CF cystic fibrosis ). In this institutional review board-approved study, 38 patients with CF cystic fibrosis (age range, 6-58 years; 21 patients <18 years and 17 patients >18 years) underwent investigative CT (at minimal exposure settings combined with iterative reconstruction) as a replacement of yearly follow-up posteroanterior chest radiography. Verbal informed consent was obtained from all patients or their parents. CT images were randomized and rated independently by two radiologists with use of the Bhalla scoring system. In addition, mosaic perfusion was evaluated. As reference, the previous available conventional chest CT scan was used. Differences in Bhalla scores were assessed with the χ(2) test and intraclass correlation coefficients ( ICC intraclass correlation coefficient s). Radiation doses for CT and radiography were assessed for adults (>18 years) and children (<18 years) separately by using technical dose descriptors and estimated effective dose. Differences in dose were assessed with the Mann-Whitney U test. The median effective dose for the investigative protocol was 0.04 mSv (95% confidence interval [ CI confidence interval ]: 0.034 mSv, 0.10 mSv) for children and 0.05 mSv (95% CI confidence interval : 0.04 mSv, 0.08 mSv) for adults. These doses were much lower than those with conventional CT (median: 0.52 mSv [95% CI confidence interval : 0.31 mSv, 3.90 mSv] for children and 1.12 mSv [95% CI confidence interval : 0.57 mSv, 3.15 mSv] for adults) and of the same order of magnitude as those for conventional radiography (median: 0.012 mSv [95% CI confidence interval : 0.006 mSv, 0.022 mSv] for children and 0.012 mSv [95% CI confidence interval : 0.005 mSv, 0.031 mSv] for adults). All images were rated at least as diagnostically acceptable. Very good agreement was found in overall Bhalla score ( ICC intraclass correlation coefficient , 0.96) with regard to the severity of bronchiectasis ( ICC intraclass correlation coefficient , 0.87) and sacculations and abscesses ( ICC intraclass correlation coefficient , 0.84). Interobserver agreement was excellent ( ICC intraclass correlation coefficient , 0.86-1). For patients with CF cystic fibrosis , a dedicated chest CT protocol can replace the two yearly follow-up chest radiographic examinations without major dose penalty and with similar diagnostic quality compared with conventional CT.
Silsupadol, Patima; Teja, Kunlanan; Lugade, Vipul
2017-10-01
The assessment of spatiotemporal gait parameters is a useful clinical indicator of health status. Unfortunately, most assessment tools require controlled laboratory environments which can be expensive and time consuming. As smartphones with embedded sensors are becoming ubiquitous, this technology can provide a cost-effective, easily deployable method for assessing gait. Therefore, the purpose of this study was to assess the reliability and validity of a smartphone-based accelerometer in quantifying spatiotemporal gait parameters when attached to the body or in a bag, belt, hand, and pocket. Thirty-four healthy adults were asked to walk at self-selected comfortable, slow, and fast speeds over a 10-m walkway while carrying a smartphone. Step length, step time, gait velocity, and cadence were computed from smartphone-based accelerometers and validated with GAITRite. Across all walking speeds, smartphone data had excellent reliability (ICC 2,1 ≥0.90) for the body and belt locations, with bag, hand, and pocket locations having good to excellent reliability (ICC 2,1 ≥0.69). Correlations between the smartphone-based and GAITRite-based systems were very high for the body (r=0.89, 0.98, 0.96, and 0.87 for step length, step time, gait velocity, and cadence, respectively). Similarly, Bland-Altman analysis demonstrated that the bias approached zero, particularly in the body, bag, and belt conditions under comfortable and fast speeds. Thus, smartphone-based assessments of gait are most valid when placed on the body, in a bag, or on a belt. The use of a smartphone to assess gait can provide relevant data to clinicians without encumbering the user and allow for data collection in the free-living environment. Copyright © 2017 Elsevier B.V. All rights reserved.
Alveolar bone level changes in maxillary expansion treatments assessed through CBCT.
Pham, Vi; Lagravère, Manuel O
2017-03-01
Determine changes in alveolar bone levels during expansion treatments as assessed through cone-beam computer tomography (CBCT). Sixty-one patients from Edmonton, Canada, with maxillary transverse deficiencies were split into three groups. One group was treated with a bone-anchored expander, another group was treated with a tooth-borne maxillary expander (Hyrax) and one group was untreated. CBCTs were obtained from each patient at two time points (initialT 1 and at removal of appliance after 6 months T 2 ). CBCTs were analyzed using AVIZO software and landmarks were placed on different dental and skeletal structures. Intra-examiner reliability for landmarks was done by randomly selecting 10 images and measuring each landmark 3 times, 1 week apart. Descriptive statistics, intraclass correlation coefficients (ICC) and ANOVA analysis were used to determine if there were changes to the alveolar bone levels and if these changes were statistically significant within each group. Landmarks reliability showed an ICC of at least 0.99 with a 95% confidence interval and a mean measurement error of at least 0.2067mm. Descriptive statistics show that changes in alveolar bone levels were less than 1mm for all three groups and therefore clinically insignificant. Changes between groups were not statistically different (P<0.05) from one another with the exception of 8 distances. However, since the distances were small, they were not considered clinically significant. Alveolar bone level changes were similar in maxillary expansion treatments and in the control group. The effects of maxillary expansion treatments on alveolar bone levels are not clinically significant. Copyright © 2016 CEO. Published by Elsevier Masson SAS. All rights reserved.
Aarts, Pauline B M; Jongerius, Peter H; Geerdink, Yvonne A; Geurts, Alexander C
2009-11-25
In 2003 new computer software, the VOAA (Video Observations Aarts and Aarts), was designed to score and evaluate two important aspects of spontaneous upper limb use, i.e. overall duration and frequency of specific behaviours. The aim of this study was to investigate the test-retest, interrater and intrarater reliability and the construct validity of a new module, the VOAA-DDD, to determine developmental disregard in children with spastic unilateral cerebral palsy (CP). A test-retest design with three raters for reliability and a two-group design for construct validity were used. Subjects were a total of 20 children with spastic unilateral CP equally divided in two age groups (2.5-5 and 5-8 years), and 56 healthy children of the same age groups. Overall duration and frequency of specific behaviours of the affected arm and hand were assessed during a task demanding ('stringing beads') and a task stimulating ('decorating a muffin') the use of both hands. Reliability was estimated by intraclass correlation coefficients (ICCs). Construct validity was assessed by comparing children with CP to healthy children. All ICCs exceeded 0.87. In contrast with healthy children, children with CP used their affected hand less during the 'muffin' task compared to the 'beads' task. Of the children with CP, 90% in the age group of 2.5-5 years and 50% in the age group of 5-8 years showed values exceeding the extreme values of healthy controls, respectively, indicating developmental disregard. The VOAA-DDD is a reliable and valid instrument to assess spontaneous use of the affected arm and hand in order to determine developmental disregard in children with spastic unilateral CP.
Saha, Supriya K.; Gordan, John D.; Kleinstiver, Benjamin P.; Vu, Phuong; Najem, Mortada S.; Yeo, Jia-Chi; Shi, Lei; Kato, Yasutaka; Levin, Rebecca S.; Webber, James T.; Damon, Leah J.; Egan, Regina K.; Greninger, Patricia; McDermott, Ultan; Garnett, Mathew J.; Jenkins, Roger L.; Rieger-Christ, Kimberly M.; Sullivan, Travis B.; Hezel, Aram F.; Liss, Andrew S.; Mizukami, Yusuke; Goyal, Lipika; Ferrone, Cristina R.; Zhu, Andrew X.; Joung, J. Keith; Shokat, Kevan M.; Benes, Cyril H.; Bardeesy, Nabeel
2017-01-01
Intrahepatic cholangiocarcinoma (ICC) is an aggressive liver bile duct malignancy exhibiting frequent isocitrate dehydrogenase (IDH1/IDH2) mutations. Through a high-throughput drug screen of a large panel of cancer cell lines including 17 biliary tract cancers, we found that IDH mutant (IDHm) ICC cells demonstrate a striking response to the multi-kinase inhibitor dasatinib, with the highest sensitivity among 682 solid tumor cell lines. Using unbiased proteomics to capture the activated kinome and CRISPR/Cas9-based genome editing to introduce dasatinib-resistant ‘gatekeeper’ mutant kinases, we identified SRC as a critical dasatinib target in IDHm ICC. Importantly, dasatinib-treated IDHm xenografts exhibited pronounced apoptosis and tumor regression. Our results show that IDHm ICC cells have a unique dependency on SRC and suggest that dasatinib may have therapeutic benefit against IDHm ICC. Moreover, these proteomic and genome-editing strategies provide a systematic and broadly applicable approach to define targets of kinase inhibitors underlying drug responsiveness. PMID:27231123
Baschung Pfister, Pierrette; Sterkele, Iris; Maurer, Britta; de Bie, Rob A.; Knols, Ruud H.
2018-01-01
Manual muscle testing (MMT) and hand-held dynamometry (HHD) are commonly used in people with inflammatory myopathy (IM), but their clinimetric properties have not yet been sufficiently studied. To evaluate the reliability and validity of MMT and HHD, maximum isometric strength was measured in eight muscle groups across three measurement events. To evaluate reliability of HHD, intra-class correlation coefficients (ICC), the standard error of measurements (SEM) and smallest detectable changes (SDC) were calculated. To measure reliability of MMT linear Cohen`s Kappa was computed for single muscle groups and ICC for total score. Additionally, correlations between MMT8 and HHD were evaluated with Spearman Correlation Coefficients. Fifty people with myositis (56±14 years, 76% female) were included in the study. Intra-and interrater reliability of HHD yielded excellent ICCs (0.75–0.97) for all muscle groups, except for interrater reliability of ankle extension (0.61). The corresponding SEMs% ranged from 8 to 28% and the SDCs% from 23 to 65%. MMT8 total score revealed excellent intra-and interrater reliability (ICC>0.9). Intrarater reliability of single muscle groups was substantial for shoulder and hip abduction, elbow and neck flexion, and hip extension (0.64–0.69); moderate for wrist (0.53) and knee extension (0.49) and fair for ankle extension (0.35). Interrater reliability was moderate for neck flexion (0.54) and hip abduction (0.44); fair for shoulder abduction, elbow flexion, wrist and ankle extension (0.20–0.33); and slight for knee extension (0.08). Correlations between the two tests were low for wrist, knee, ankle, and hip extension; moderate for elbow flexion, neck flexion and hip abduction; and good for shoulder abduction. In conclusion, the MMT8 total score is a reliable assessment to consider general muscle weakness in people with myositis but not for single muscle groups. In contrast, our results confirm that HHD can be recommended to evaluate strength of single muscle groups. PMID:29596450
Examination of the Test-Retest Reliability of a Computerized Neurocognitive Test Battery.
Nakayama, Yusuke; Covassin, Tracey; Schatz, Philip; Nogle, Sally; Kovan, Jeff
2014-08-01
Test-retest reliability is a critical issue in the utility of computer-based neurocognitive assessment paradigms employing baseline and postconcussion tests. Researchers have reported low test-retest reliability for the Immediate Post Concussion Assessment and Cognitive Testing (ImPACT) across an interval of 45 and 50 days. To re-examine the test-retest reliability of the ImPACT between baseline, 45 days, and 50 days. Descriptive laboratory study. Eighty-five physically active college students (51 male, 34 female) volunteered for this study. Participants completed the ImPACT as well as a 15-item memory test at baseline, 45 days, and 50 days. Intraclass correlation coefficients (ICCs) were calculated for ImPACT composite scores, and change scores were calculated using reliable change indices (RCIs) and regression-based methods (RBMs) at 80% and 95% confidence intervals (CIs). The respective ICCs for baseline to day 45, day 45 to day 50, baseline to day 50, and overall were as follows: verbal memory (0.76, 0.69, 0.65, and 0.78), visual memory (0.72, 0.66, 0.60, and 0.74), visual motor (processing) speed (0.87, 0.88, 0.85, and 0.91), and reaction time (0.67, 0.81, 0.71, and 0.80). All ICCs exceeded the threshold value of 0.60 for acceptable test-retest reliability. All cases fell well within the 80% CI for both the RCI and RBM, while 1% to 5% of cases fell outside the 95% CI for the RCI and 1% for the RBM. Results suggest that the ImPACT is a reliable neurocognitive test battery at 45 and 50 days after the baseline assessment. The current findings agree with those of other reliability studies that have reported acceptable ICCs across 30-day to 1-year testing intervals, and they support the utility of the ImPACT for the multidisciplinary approach to concussion management. This study suggests that the computerized neurocognitive test battery, ImPACT, is a reliable test for postconcussion serial assessments. However, when managing concussed athletes, the ImPACT should not be used as a stand-alone measure. © 2014 The Author(s).
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-07
... Amend Schedule 502 of the ICC Rules To Update the Contract Reference Obligation ISINs Associated With... ICC. ICC filed the proposal pursuant to Section 19(b)(3)(A)(iii) of the Act,\\3\\ and Rule 19b-4(f)(3... publishing this notice to solicit comments on the rule change from interested parties. \\1\\ 15 U.S.C. 78s(b)(1...
SRMS maneuvers the ICC-VLD during STS-127 / Expedition 20 Joint Operations
2009-07-19
S127-E-006934 (19 July 2009) --- Backdropped by a blue and white Earth, the remote manipulator system (RMS) arm of the Space Shuttle Endeavour, is about to hand off the Integrated Cargo Carrier (ICC) to the International Space Station (out of frame). The ICC is an unpressurized flat bed pallet and keel yoke assembly that was carried into space in the shuttle's payload bay.
Hayano, Koichi; Miura, Fumihiko; Amano, Hodaka; Toyota, Naoyuki; Wada, Keita; Kato, Kenichiro; Takada, Tadahiro; Asano, Takehide
2010-01-01
Significant hemobilia due to arterio-biliary fistula is a very rare complication of chemoradiation therapy (CRT) for unresectable intrahepatic cholangiocarcinoma (ICC). Here we report a case of arterio-biliary fistula after CRT for unresectable ICC demonstrated by angiographic examinations. This fistula was successfully treated by endovascular embolization. Hemobilia is a rare complication, but arterio-biliary fistula should be considered after CRT of ICC. PMID:21160700
Luis, Santiago V; Jover, Eric
2014-10-01
The 14th European Association of Chemical and Molecular Sciences (EuCheMS) International Conference on Chemistry and the Environment (ICCE 2013) took place on 25-28 June 2013 at the IEC and the WTC in Barcelona, Spain. The ICCE is a well-established biannual conference organized by the Division of Chemistry and the EuCheMS.
Apatinib inhibits VEGF signaling and promotes apoptosis in intrahepatic cholangiocarcinoma.
Peng, Hong; Zhang, Qiuyang; Li, Jiali; Zhang, Ning; Hua, Yunpeng; Xu, Lixia; Deng, Yubin; Lai, Jiaming; Peng, Zhenwei; Peng, Baogang; Chen, Minhu; Peng, Sui; Kuang, Ming
2016-03-29
Tumor cells co-express vascular endothelial growth factor (VEGF) and VEGF receptors (VEGFRs) that interact each other to support a self-sustainable cell growth. So far, this autocrine VEGF loop is not reported in human intrahepatic cholangiocarcinoma (ICC). Apatinib is a highly selective VEGFR2 inhibitor, but its effects on ICC have not been investigated. In this study, we reported that VEGF and phosphorylated VEGFR2 were expressed at a significantly high level in ICC patient tissues (P<0.05). In vitro, treating ICC cell lines RBE and SSP25 with recombinant human VEGF (rhVEGF) induced phosphorylation of VEGFR1 (pVEGFR1) and VEGFR2 (pVEGFR2); however, only the VEGFR2 played a role in the anti-apoptotic cell growth through activating a PI3K-AKT-mTOR anti-apoptotic signaling pathway which generated more VEGF to enter this autocrine loop. Apatinib inhibited the anti-apoptosis induced by VEGF signaling, and promoted cell death in vitro. In addition, Apatinib treatment delayed xenograft tumor growth in vivo. In conclusion, the autocrine VEGF/VEGFR2 signaling promotes ICC cell survival. Apatinib inhibits anti-apoptotic cell growth through suppressing the autocrine VEGF signaling, supporting a potential role for using Apatinib in the treatment of ICC.
Apatinib inhibits VEGF signaling and promotes apoptosis in intrahepatic cholangiocarcinoma
Zhang, Ning; Hua, Yunpeng; Xu, Lixia; Deng, Yubin; Lai, Jiaming; Peng, Zhenwei; Peng, Baogang; Chen, Minhu; Peng, Sui; Kuang, Ming
2016-01-01
Tumor cells co-express vascular endothelial growth factor (VEGF) and VEGF receptors (VEGFRs) that interact each other to support a self-sustainable cell growth. So far, this autocrine VEGF loop is not reported in human intrahepatic cholangiocarcinoma (ICC). Apatinib is a highly selective VEGFR2 inhibitor, but its effects on ICC have not been investigated. In this study, we reported that VEGF and phosphorylated VEGFR2 were expressed at a significantly high level in ICC patient tissues (P<0.05). In vitro, treating ICC cell lines RBE and SSP25 with recombinant human VEGF (rhVEGF) induced phosphorylation of VEGFR1 (pVEGFR1) and VEGFR2 (pVEGFR2); however, only the VEGFR2 played a role in the anti-apoptotic cell growth through activating a PI3K-AKT-mTOR anti-apoptotic signaling pathway which generated more VEGF to enter this autocrine loop. Apatinib inhibited the anti-apoptosis induced by VEGF signaling, and promoted cell death in vitro. In addition, Apatinib treatment delayed xenograft tumor growth in vivo. In conclusion, the autocrine VEGF/VEGFR2 signaling promotes ICC cell survival. Apatinib inhibits anti-apoptotic cell growth through suppressing the autocrine VEGF signaling, supporting a potential role for using Apatinib in the treatment of ICC. PMID:26967384
Intra-class correlation estimates for assessment of vitamin A intake in children.
Agarwal, Girdhar G; Awasthi, Shally; Walter, Stephen D
2005-03-01
In many community-based surveys, multi-level sampling is inherent in the design. In the design of these studies, especially to calculate the appropriate sample size, investigators need good estimates of intra-class correlation coefficient (ICC), along with the cluster size, to adjust for variation inflation due to clustering at each level. The present study used data on the assessment of clinical vitamin A deficiency and intake of vitamin A-rich food in children in a district in India. For the survey, 16 households were sampled from 200 villages nested within eight randomly-selected blocks of the district. ICCs and components of variances were estimated from a three-level hierarchical random effects analysis of variance model. Estimates of ICCs and variance components were obtained at village and block levels. Between-cluster variation was evident at each level of clustering. In these estimates, ICCs were inversely related to cluster size, but the design effect could be substantial for large clusters. At the block level, most ICC estimates were below 0.07. At the village level, many ICC estimates ranged from 0.014 to 0.45. These estimates may provide useful information for the design of epidemiological studies in which the sampled (or allocated) units range in size from households to large administrative zones.
Fontanesi, Luca; Vargiolu, Manuela; Scotti, Emilio; Latorre, Rocco; Faussone Pellegrini, Maria Simonetta; Mazzoni, Maurizio; Asti, Martina; Chiocchetti, Roberto; Romeo, Giovanni; Clavenzani, Paolo; De Giorgio, Roberto
2014-01-01
The English spotting coat color locus in rabbits, also known as Dominant white spotting locus, is determined by an incompletely dominant allele (En). Rabbits homozygous for the recessive wild-type allele (en/en) are self-colored, heterozygous En/en rabbits are normally spotted, and homozygous En/En animals are almost completely white. Compared to vital en/en and En/en rabbits, En/En animals are subvital because of a dilated ("mega") cecum and ascending colon. In this study, we investigated the role of the KIT gene as a candidate for the English spotting locus in Checkered Giant rabbits and characterized the abnormalities affecting enteric neurons and c-kit positive interstitial cells of Cajal (ICC) in the megacolon of En/En rabbits. Twenty-one litters were obtained by crossing three Checkered Giant bucks (En/en) with nine Checkered Giant (En/en) and two en/en does, producing a total of 138 F1 and backcrossed rabbits. Resequencing all coding exons and portions of non-coding regions of the KIT gene in 28 rabbits of different breeds identified 98 polymorphisms. A single nucleotide polymorphism genotyped in all F1 families showed complete cosegregation with the English spotting coat color phenotype (θ=0.00 LOD =75.56). KIT gene expression in cecum and colon specimens of En/En (pathological) rabbits was 5-10% of that of en/en (control) rabbits. En/En rabbits showed reduced and altered c-kit immunolabelled ICC compared to en/en controls. Morphometric data on whole mounts of the ascending colon showed a significant decrease of HuC/D (P<0.05) and substance P (P<0.01) immunoreactive neurons in En/En vs. en/en. Electron microscopy analysis showed neuronal and ICC abnormalities in En/En tissues. The En/En rabbit model shows neuro-ICC changes reminiscent of the human non-aganglionic megacolon. This rabbit model may provide a better understanding of the molecular abnormalities underlying conditions associated with non-aganglionic megacolon.
Fontanesi, Luca; Vargiolu, Manuela; Scotti, Emilio; Latorre, Rocco; Faussone Pellegrini, Maria Simonetta; Mazzoni, Maurizio; Asti, Martina; Chiocchetti, Roberto; Romeo, Giovanni; Clavenzani, Paolo; De Giorgio, Roberto
2014-01-01
The English spotting coat color locus in rabbits, also known as Dominant white spotting locus, is determined by an incompletely dominant allele (En). Rabbits homozygous for the recessive wild-type allele (en/en) are self-colored, heterozygous En/en rabbits are normally spotted, and homozygous En/En animals are almost completely white. Compared to vital en/en and En/en rabbits, En/En animals are subvital because of a dilated (“mega”) cecum and ascending colon. In this study, we investigated the role of the KIT gene as a candidate for the English spotting locus in Checkered Giant rabbits and characterized the abnormalities affecting enteric neurons and c-kit positive interstitial cells of Cajal (ICC) in the megacolon of En/En rabbits. Twenty-one litters were obtained by crossing three Checkered Giant bucks (En/en) with nine Checkered Giant (En/en) and two en/en does, producing a total of 138 F1 and backcrossed rabbits. Resequencing all coding exons and portions of non-coding regions of the KIT gene in 28 rabbits of different breeds identified 98 polymorphisms. A single nucleotide polymorphism genotyped in all F1 families showed complete cosegregation with the English spotting coat color phenotype (θ = 0.00 LOD = 75.56). KIT gene expression in cecum and colon specimens of En/En (pathological) rabbits was 5–10% of that of en/en (control) rabbits. En/En rabbits showed reduced and altered c-kit immunolabelled ICC compared to en/en controls. Morphometric data on whole mounts of the ascending colon showed a significant decrease of HuC/D (P<0.05) and substance P (P<0.01) immunoreactive neurons in En/En vs. en/en. Electron microscopy analysis showed neuronal and ICC abnormalities in En/En tissues. The En/En rabbit model shows neuro-ICC changes reminiscent of the human non-aganglionic megacolon. This rabbit model may provide a better understanding of the molecular abnormalities underlying conditions associated with non-aganglionic megacolon. PMID:24736498
Macedo-Ojeda, Gabriela; Vizmanos-Lamotte, Barbara; Márquez-Sandoval, Yolanda Fabiola; Rodríguez-Rocha, Norma Patricia; López-Uriarte, Patricia Josefina; Fernández-Ballart, Joan D
2013-11-01
Semi-quantitative Food Frequency Questionnaires (FFQs) analyze average food and nutrient intake over extended periods to associate habitual dietary intake with health problems and chronic diseases. A tool of this nature applicable to both women and men is not presently available in Mexico. To validate a FFQ for adult men and women. The study was conducted on 97 participants, 61% were women. Two FFQs were administered (with a one-year interval) to measure reproducibility. To assess validity, the second FFQ was compared against dietary record (DR) covering nine days. Statistical analyses included Pearson correlations and Intraclass Correlation Coefficients (ICC). The de-attenuation of the ICC resulting from intraindividual variability was controlled. The validity analysis was complemented by comparing the classification ability of FFQ to that of DR through concordance between intake categories and Bland-Altman plots. Reproducibility: ICC values for food groups ranged 0.42-0.87; the range for energy and nutrients was between 0.34 and 0.82. ICC values for food groups ranged 0.35-0.84; the range for energy and nutrients was between 0.36 and 0.77. Most subjects (56.7-76.3%) classified in the same or adjacent quintile for energy and nutrients using both methods. Extreme misclassification was <6.3% for all items. Bland-Altman plots reveal high concordance between FFQ and DR. FFQ produced sufficient levels of reproducibility and validity to determine average daily intake over one year. These results will enable the analysis of possible associations with chronic diseases and dietary diagnoses in adult populations of men and women. Copyright AULA MEDICA EDICIONES 2013. Published by AULA MEDICA. All rights reserved.
Li, Hai; Chen, Yan; Liu, Shi; Hou, Xiao-Hua
2016-06-21
To investigate the effects of different parameters of gastric electrical stimulation (GES) on interstitial cells of Cajal (ICCs) and changes in the insulin-like growth factor 1 (IGF-1) signal pathway in streptozotocin-induced diabetic rats. Male rats were randomized into control, diabetic (DM), diabetic with sham GES (DM + SGES), diabetic with GES1 (5.5 cpm, 100 ms, 4 mA) (DM + GES1), diabetic with GES2 (5.5 cpm, 300 ms, 4 mA) (DM + GES2) and diabetic with GES3 (5.5 cpm, 550 ms, 2 mA) (DM + GES3) groups. The expression levels of c-kit, M-SCF and IGF-1 receptors were evaluated in the gastric antrum using Western blot analysis. The distribution of ICCs was observed using immunolabeling for c-kit, while smooth muscle cells and IGF-1 receptors were identified using α-SMA and IGF-1R antibodies. Serum level of IGF-1 was tested using enzyme-linked immunosorbent assay. Gastric emptying was delayed in the DM group but improved in all GES groups, especially in the GES2 group. The expression levels of c-kit, M-SCF and IGF-1R were decreased in the DM group but increased in all GES groups. More ICCs (c-kit(+)) and smooth muscle cells (α-SMA(+)/IGF-1R(+)) were observed in all GES groups than in the DM group. The average level of IGF-1 in the DM group was markedly decreased, but it was up-regulated in all GES groups, especially in the GES2 group. The results suggest that long-pulse GES promotes the regeneration of ICCs. The IGF-1 signaling pathway might be involved in the mechanism underlying this process, which results in improved gastric emptying.
Palliative sedation: reliability and validity of sedation scales.
Arevalo, Jimmy J; Brinkkemper, Tijn; van der Heide, Agnes; Rietjens, Judith A; Ribbe, Miel; Deliens, Luc; Loer, Stephan A; Zuurmond, Wouter W A; Perez, Roberto S G M
2012-11-01
Observer-based sedation scales have been used to provide a measurable estimate of the comfort of nonalert patients in palliative sedation. However, their usefulness and appropriateness in this setting has not been demonstrated. To study the reliability and validity of observer-based sedation scales in palliative sedation. A prospective evaluation of 54 patients under intermittent or continuous sedation with four sedation scales was performed by 52 nurses. Included scales were the Minnesota Sedation Assessment Tool (MSAT), Richmond Agitation-Sedation Scale (RASS), Vancouver Interaction and Calmness Scale (VICS), and a sedation score proposed in the Guideline for Palliative Sedation of the Royal Dutch Medical Association (KNMG). Inter-rater reliability was tested with the intraclass correlation coefficient (ICC) and Cohen's kappa coefficient. Correlations between the scales using Spearman's rho tested concurrent validity. We also examined construct, discriminative, and evaluative validity. In addition, nurses completed a user-friendliness survey. Overall moderate to high inter-rater reliability was found for the VICS interaction subscale (ICC = 0.85), RASS (ICC = 0.73), and KNMG (ICC = 0.71). The largest correlation between scales was found for the RASS and KNMG (rho = 0.836). All scales showed discriminative and evaluative validity, except for the MSAT motor subscale and VICS calmness subscale. Finally, the RASS was less time consuming, clearer, and easier to use than the MSAT and VICS. The RASS and KNMG scales stand as the most reliable and valid among the evaluated scales. In addition, the RASS was less time consuming, clearer, and easier to use than the MSAT and VICS. Further research is needed to evaluate the impact of the scales on better symptom control and patient comfort. Copyright © 2012 U.S. Cancer Pain Relief Committee. Published by Elsevier Inc. All rights reserved.
Intra-arterial embolotherapy for intrahepatic cholangiocarcinoma: update and future prospects.
Savic, Lynn Jeanette; Chapiro, Julius; Geschwind, Jean-François H
2017-02-01
Intrahepatic cholangiocarcinoma (ICC) is a rare disease and carries a poor prognosis with surgery remaining the only curative treatment option. However, due to the late presentation of symptoms and close proximity of the tumors to central hepatic structures, only about 30% of patients are classified eligible to resection. As for palliative approaches, ICC constitutes a possible indication for loco-regional therapies (LRT). As such, intra-arterial therapies (IAT) are reported to be feasible, safe and effective in inducing tumor response in unresectable ICC. The paradigm of IAT is premised on the selective delivery of embolic, chemotherapeutic agents to the tumor via its feeding arteries, thus allowing dose escalation within the carcinoma and reduction of systemic toxicity. Conventional transcatheter arterial chemoembolization (cTACE) so far remains the most commonly used IAT modality. However, drug-eluting beads (DEB)-TACE was initiated with the idea of more selective targeting of the tumor owing to the combined embolizing as well as drug-eluting properties of the microspheres used in this setting. Moreover, radioembolization is performed by intra-arterial administration of very small spheres containing β-emitting yttrium-90 (Y90-RE) to the site of the tumor. Clinical evidence exists in support of survival benefits for IAT in the palliative treatment of ICC compared to surgery and systemic chemotherapy. As for combination regimens, cTACE, DEB-TACE and Y90-RE are reported to achieve conversion of patients to surgery in a sequential treatment planning and simultaneous IAT combinations may provide a therapeutic option for treatment escalation. Regarding the current status of literature, controlled randomized prospective trials to compare different IAT techniques and combination therapies as well as treatment recommendations for different IAT modalities are needed.
Maksymowych, Walter P; Cibere, Jolanda; Loeuille, Damien; Weber, Ulrich; Zubler, Veronika; Roemer, Frank W; Jaremko, Jacob L; Sayre, Eric C; Lambert, Robert G W
2014-02-01
Development of a validated magnetic resonance image (MRI) scoring system is essential in hip OA because radiographs are insensitive to change. We assessed the feasibility and reliability of 2 previously developed scoring methods: (1) the Hip Inflammation MRI Scoring System (HIMRISS) and (2) the Hip Osteoarthritis MRI Scoring System (HOAMS). Six readers (3 radiologists, 3 rheumatologists) participated in 2 reading exercises. In Reading Exercise 1, MRI of the hip of 20 subjects were read at a single time point followed by further standardization of methodology. In Reading Exercise 2, MRI of the hip of 18 subjects from a randomized controlled trial, assessed at 2 timepoints, and 27 subjects from a cross-sectional study were read for HIMRISS and HOAMS bone marrow lesions (BML) and synovitis. Reliability was assessed using intraclass correlation coefficient (ICC) and kappa statistics. Both methods were considered feasible. For Reading 1, HIMRISS ICC were 0.52, 0.61, 0.70, and 0.58 for femoral BML, acetabular BML, effusion, and total scores, respectively; and for HOAMS, summed BML and synovitis ICC were 0.52 and 0.46, respectively. For Reading 2, HIMRISS and HOAMS ICC for BML and synovitis-effusion improved substantially. Interobserver reliability for change scores was 0.81 and 0.71 for HIMRISS femoral and HOAMS summed BML, respectively. Responsiveness and discrimination was moderate to high for synovitis-effusion. Significant associations were noted between BML or synovitis scores and Western Ontario and McMaster Universities Osteoarthritis Index pain scores for baseline values (p ≤ 0.001). The BML and synovitis-effusion components of both HIMRISS and HOAMS scoring systems are feasible and reliable, and should be validated further.
Decreased expression of Kv7 channels in Hirchsprung's disease.
O'Donnell, Anne-Marie; Coyle, David; Puri, Prem
2017-07-01
Voltage-dependent K + channels (Kv channels) participate in electrical rhythmicity and smooth muscle responses and are regulated by excitatory and inhibitory neurotransmitters. Kv channels also participate in the interstitial cell of Cajal (ICC) and smooth muscle cell (SMC) responses to neural inputs. The Kv family consists of 12 subfamilies, Kv1-Kv12, with five members of the Kv7 family identified to date: Kv7.1-Kv7.5. A recent study identified the potassium channel Kv7.5 as having a role in the excitability of ICC-IM in the mouse colon. We therefore designed this study to test the hypothesis that Kv7 channels are present in the normal human colon and are reduced in Hirschprung's disease (HSCR). HSCR tissue specimens were collected at the time of pull-through surgery (n=10), while normal control tissue specimens were obtained at the time of colostomy closure in patients with imperforate anus (n=10). Kv7.3-Kv7.5 immunohistochemistry was performed and visualized using confocal microscopy to assess their distribution. Western blot analysis was undertaken to determine Kv7.3-Kv7.5 protein quantification. Kv7.3 and Kv7.4-immunoreactivity was co-localized with neuron and ICC markers, while Kv7.5 was found to be expressed on both ICCs and SMCs. Western blot analysis revealed similar levels of Kv7.3 and Kv7.5 expression in the normal colon and HSCR colon, while Kv7.4 proteins were found to be markedly decreased in ganglionic specimens and decreased further in aganglionic specimens. A deficiency of Kv7.4 channels in the ganglionic and aganglionic bowel may place a role in colonic dysmotility in HSCR. Copyright © 2017 Elsevier Inc. All rights reserved.
Kim, Jooseong
2016-01-01
Objective The aim of this study was to compare the accuracy of Bolton analysis obtained from digital models scanned with the Ortho Insight three-dimensional (3D) laser scanner system to those obtained from cone-beam computed tomography (CBCT) images and traditional plaster models. Methods CBCT scans and plaster models were obtained from 50 patients. Plaster models were scanned using the Ortho Insight 3D laser scanner; Bolton ratios were calculated with its software. CBCT scans were imported and analyzed using AVIZO software. Plaster models were measured with a digital caliper. Data were analyzed with descriptive statistics and the intraclass correlation coefficient (ICC). Results Anterior and overall Bolton ratios obtained by the three different modalities exhibited excellent agreement (> 0.970). The mean differences between the scanned digital models and physical models and between the CBCT images and scanned digital models for overall Bolton ratios were 0.41 ± 0.305% and 0.45 ± 0.456%, respectively; for anterior Bolton ratios, 0.59 ± 0.520% and 1.01 ± 0.780%, respectively. ICC results showed that intraexaminer error reliability was generally excellent (> 0.858 for all three diagnostic modalities), with < 1.45% discrepancy in the Bolton analysis. Conclusions Laser scanned digital models are highly accurate compared to physical models and CBCT scans for assessing the spatial relationships of dental arches for orthodontic diagnosis. PMID:26877978
Accuracy of laser-scanned models compared to plaster models and cone-beam computed tomography.
Kim, Jooseong; Heo, Giseon; Lagravère, Manuel O
2014-05-01
To compare the accuracy of measurements obtained from the three-dimensional (3D) laser scans to those taken from the cone-beam computed tomography (CBCT) scans and those obtained from plaster models. Eighteen different measurements, encompassing mesiodistal width of teeth and both maxillary and mandibular arch length and width, were selected using various landmarks. CBCT scans and plaster models were prepared from 60 patients. Plaster models were scanned using the Ortho Insight 3D laser scanner, and the selected landmarks were measured using its software. CBCT scans were imported and analyzed using the Avizo software, and the 26 landmarks corresponding to the selected measurements were located and recorded. The plaster models were also measured using a digital caliper. Descriptive statistics and intraclass correlation coefficient (ICC) were used to analyze the data. The ICC result showed that the values obtained by the three different methods were highly correlated in all measurements, all having correlations>0.808. When checking the differences between values and methods, the largest mean difference found was 0.59 mm±0.38 mm. In conclusion, plaster models, CBCT models, and laser-scanned models are three different diagnostic records, each with its own advantages and disadvantages. The present results showed that the laser-scanned models are highly accurate to plaster models and CBCT scans. This gives general clinicians an alternative to take into consideration the advantages of laser-scanned models over plaster models and CBCT reconstructions.
Vasconcelos, Taruska Ventorini; Neves, Frederico Sampaio; Moraes, Lívia Almeida Bueno; Freitas, Deborah Queiroz
2015-01-01
This article aimed at comparing the accuracy of linear measurement tools of different commercial software packages. Eight fully edentulous dry mandibles were selected for this study. Incisor, canine, premolar, first molar and second molar regions were selected. Cone beam computed tomography (CBCT) images were obtained with i-CAT Next Generation. Linear bone measurements were performed by one observer on the cross-sectional images using three different software packages: XoranCat®, OnDemand3D® and KDIS3D®, all able to assess DICOM images. In addition, 25% of the sample was reevaluated for the purpose of reproducibility. The mandibles were sectioned to obtain the gold standard for each region. Intraclass coefficients (ICC) were calculated to examine the agreement between the two periods of evaluation; the one-way analysis of variance performed with the post-hoc Dunnett test was used to compare each of the software-derived measurements with the gold standard. The ICC values were excellent for all software packages. The least difference between the software-derived measurements and the gold standard was obtained with the OnDemand3D and KDIS3D (-0.11 and -0.14 mm, respectively), and the greatest, with the XoranCAT (+0.25 mm). However, there was no statistical significant difference between the measurements obtained with the different software packages and the gold standard (p> 0.05). In conclusion, linear bone measurements were not influenced by the software package used to reconstruct the image from CBCT DICOM data.
Jensen, K K; Kjaer, M; Jorgensen, L N
2016-12-01
To determine the reliability of measurements obtained by the Good Strength dynamometer, determining isometric abdominal wall and back muscle strength in patients with ventral incisional hernia (VIH) and healthy volunteers with an intact abdominal wall. Ten patients with VIH and ten healthy volunteers with an intact abdominal wall were each examined twice with a 1 week interval. Examination included the assessment of truncal flexion and extension as measured with the Good Strength dynamometer, the completion of the International Physical Activity Questionnaire (IPAQ) and the self-assessment of truncal strength on a visual analogue scale (SATS). The test-retest reliability of truncal flexion and extension was assessed by interclass correlation coefficient (ICC), and Bland and Altman graphs. Finally, correlations between truncal strength, and IPAQ and SATS were examined. Truncal flexion and extension showed excellent test-retest reliability for both patients with VIH (ICC 0.91 and 0.99) and healthy controls (ICC 0.97 and 0.96). Bland and Altman plots showed that no systematic bias was present for neither truncal flexion nor extension when assessing reliability. For patients with VIH, no significant correlations between objective measures of truncal strength and IPAQ or SATS were found. For healthy controls, both truncal flexion (τ 0.58, p = 0.025) and extension (τ 0.58, p = 0.025) correlated significantly with SATS, while no other significant correlation between truncal strength measures and IPAQ was found. The Good Strength dynamometer provided a reliable, low-cost measure of truncal flexion and extension in patients with VIH.
Badjatia, Neeraj; O'Donnell, Joan; Baker, John R; Huang, David; Ayata, Cenk; Greer, David M; Carter, Bob S; Ogilvy, Christopher S; McDonald, Colin T
2004-01-01
Fever is common and difficult to control in patients with subarachnoid hemorrhage (SAH). We have previously shown an inverse relationship between fever and outcome in patients with SAH. This was a prospective, single-arm, feasibility trial in which nine patients with SAH underwent temperature management using an intravascular cooling catheter (ICC) to restore and maintain 24 hours of normothermia (36.5 degrees+/-0.2 degrees C). Enrollment occurred after development of a fever of at least 38.3 degrees C within 7 days of SAH that was refractory to acetaminophen treatment. The ICC was placed at the bedside through an introducer sheath via the femoral vein into the inferior vena cava (IVC). Portable X-ray confirmed placement. Normothermia was achieved in seven of the nine patients treated (78%); it was achieved in 100% of the patients with a 14F catheter (n=4) and in 60% of the patients with a 9F catheter (n=5). The two patients not reaching normothermia were not adequately treated for shivering. All other patients reached normothermia irrespective of intubation status. Overall, normothermia was well tolerated and not discontinued because of discomfort or adverse events. Two incidences of deep vein thrombosis were diagnosis by ultrasound that were not associated with clinical sequelae, and IVC filters were placed. No unanticipated adverse events occurred. We have demonstrated that fever can be safely and effectively controlled in patients with SAH for at least 24 hours using an ICC. Future studies are needed to assess the effect of such sustained therapy on outcome in patients with SAH.
de Araujo-Barbosa, Paulo Henrique Ferreira; de Menezes, Lidiane Teles; Costa, Abraão Souza; Couto Paz, Clarissa Cardoso Dos Santos; Fachin-Martins, Emerson
2015-05-01
Described as an alternative way of assessing weight-bearing asymmetries, the measures obtained from digital scales have been used as an index to classify weight-bearing distribution. This study aimed to describe the intra-test and the test/retest reliability of measures in subjects with and without hemiparesis during quiet stance. The percentage of body weight borne by one limb was calculated for a sample of subjects with hemiparesis and for a control group that was matched by gender and age. A two-way analysis of variance was used to verify the intra-test reliability. This analysis was calculated using the differences between the averages of the measures obtained during single, double or triple trials. The intra-class correlation coefficient (ICC) was utilized and data plotted using the Bland-Altman method. The intra-test analysis showed significant differences, only observed in the hemiparesis group, between the measures obtained by single and triple trials. Excellent and moderate ICC values (0.69-0.84) between test and retest were observed in the hemiparesis group, while for control groups ICC values (0.41-0.74) were classified as moderate, progressing from almost poor for measures obtained by a single trial to almost excellent for those obtained by triple trials. In conclusion, good reliability ranging from moderate to excellent classifications was found for participants with and without hemiparesis. Moreover, an improvement of the repeatability was observed with fewer trials for participants with hemiparesis, and with more trials for participants without hemiparesis.
Morphology combined with ancillary techniques: An algorithm approach for thyroid nodules.
Rossi, E D; Martini, M; Capodimonti, S; Cenci, T; Bilotta, M; Pierconti, F; Pontecorvi, A; Lombardi, C P; Fadda, G; Larocca, L M
2018-04-23
Several authors have underlined the limits of morphological analysis mostly in the diagnosis of follicular neoplasms (FN). The application of ancillary techniques, including immunocytochemistry (ICC) and molecular testing, contributes to a better definition of the risk of malignancy (ROM) and management of FN. According to literature, the application of models, including the evaluation of ICC, somatic mutations (ie, BRAF V 600E ), micro RNA analysis is proposed for FNs. This study discusses the validation of a diagnostic algorithm in FN with a special focus on the role of morphology then followed by ancillary techniques. From June 2014 to January 2016, we enrolled 37 FNs with histological follow-up. In the same reference period, 20 benign nodules and 20 positive for malignancy were selected as control. ICC, BRAF V 600E mutation and miR-375 were carried out on LBC. The 37 FNs included 14 atypia of undetermined significance/follicular lesion of undetermined significance and 23 FN. Specifically, atypia of undetermined significance/follicular lesion of undetermined significance resulted in three goitres, 10 follicular adenomas and one NIFTP whereas FN/suspicious for FN by seven follicular adenomas and 16 malignancies (nine non-invasive follicular thyroid neoplasms with papillary-like nuclear features, two invasive follicular variant of papillary thyroid carcinoma [PTC] and five PTC). The 20 positive for malignancy samples included two invasive follicular variant of PTC, 16 PTCs and two medullary carcinomas. The morphological features of BRAF V 600E mutation (nuclear features of PTC and moderate/abundant eosinophilic cytoplasms) were associated with 100% ROM. In the wild type cases, ROM was 83.3% in presence of a concordant positive ICC panel whilst significantly lower (10.5%) in a negative concordant ICC. High expression values of MirR-375 provided 100% ROM. The adoption of an algorithm might represent the best choice for the correct diagnosis of FNs. The morphological detection of BRAF V 600E represents the first step for the identification of malignant FNs. A significant reduction of unnecessary thyroidectomies is the goal of this application. © 2018 John Wiley & Sons Ltd.
Wang, Mengmeng; Gao, Yuzhen; Feng, Huijuan; Warner, Elisa; An, Mingrui; Jia, Jian'an; Chen, Shipeng; Fang, Meng; Ji, Jun; Gu, Xing; Gao, Chunfang
2018-03-01
Intrahepatic cholangiocarcinoma (ICC) and hepatocellular carcinoma (HCC) are the most prevalent histologic types of primary liver cancer (PLC). Although ICC and HCC share similar risk factors and clinical manifestations, ICC usually bears poorer prognosis than HCC. Confidently discriminating ICC and HCC before surgery is beneficial to both treatment and prognosis. Given the lack of effective differential diagnosis biomarkers and methods, construction of models based on available clinicopathological characteristics is in need. Nomograms present a simple and efficient way to make a discrimination. A total of 2894 patients who underwent surgery for PLC were collected. Of these, 1614 patients formed the training cohort for nomogram construction, and thereafter, 1280 patients formed the validation cohort to confirm the model's performance. Histopathologically confirmed ICC was diagnosed in 401 (24.8%) and 296 (23.1%) patients in these two cohorts, respectively. A nomogram integrating six easily obtained variables (Gender, Hepatitis B surface antigen, Aspartate aminotransferase, Alpha-fetoprotein, Carcinoembryonic antigen, Carbohydrate antigen 19-9) is proposed in accordance with Akaike's Information Criterion (AIC). A score of 15 was determined as the cut-off value, and the corresponding discrimination efficacy was sufficient. Additionally, patients who scored higher than 15 suffered poorer prognosis than those with lower scores, regardless of the subtype of PLC. A nomogram for clinical discrimination of ICC and HCC has been established, where a higher score indicates ICC and poor prognosis. Further application of this nomogram in multicenter investigations may confirm the practicality of this tool for future clinical use. © 2018 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.
Haynes, Tom; Bishop, Chris; Antrobus, Mark; Brazier, Jon
2018-03-27
This is the first study to independently assess the concurrent validity and reliability of the My Jump 2 app for measuring drop jump performance. It is also the first to evaluate the app's ability to measure the reactive strength index (RSI). Fourteen male sport science students (age: 29.5 ± 9.9 years) performed three drop jumps from 20 cm and 40 cm (totalling 84 jumps), assessed via a force platform and the My Jump 2 app. Reported metrics included reactive strength index, jump height, ground contact time, and mean power. Measurements from both devices were compared using the intraclass correlation coefficient (ICC), Pearson product moment correlation coefficient (r), Cronbach's alpha (α), coefficient of variation (CV) and BlandAltman plots. Near perfect agreement was seen between devices at 20 cm for RSI (ICC = 0.95) and contact time (ICC = 0.99) and at 40 cm for RSI (ICC = 0.98), jump height (ICC = 0.96) and contact time (ICC = 0.92); with very strong agreement seen at 20 cm for jump height (ICC = 0.80). In comparison with the force plate the app showed good validity for RSI (20 cm: r = 0.94; 40 cm; r = 0.97), jump height (20 cm: r = 0.80; 40 cm; r = 0.96) and contact time (20 cm = 0.96; 40 cm; r = 0.98). The results of the present study show that the My Jump 2 app is a valid and reliable tool for assessing drop jump performance.
Accounting for twin births in sample size calculations for randomised trials.
Yelland, Lisa N; Sullivan, Thomas R; Collins, Carmel T; Price, David J; McPhee, Andrew J; Lee, Katherine J
2018-05-04
Including twins in randomised trials leads to non-independence or clustering in the data. Clustering has important implications for sample size calculations, yet few trials take this into account. Estimates of the intracluster correlation coefficient (ICC), or the correlation between outcomes of twins, are needed to assist with sample size planning. Our aims were to provide ICC estimates for infant outcomes, describe the information that must be specified in order to account for clustering due to twins in sample size calculations, and develop a simple tool for performing sample size calculations for trials including twins. ICCs were estimated for infant outcomes collected in four randomised trials that included twins. The information required to account for clustering due to twins in sample size calculations is described. A tool that calculates the sample size based on this information was developed in Microsoft Excel and in R as a Shiny web app. ICC estimates ranged between -0.12, indicating a weak negative relationship, and 0.98, indicating a strong positive relationship between outcomes of twins. Example calculations illustrate how the ICC estimates and sample size calculator can be used to determine the target sample size for trials including twins. Clustering among outcomes measured on twins should be taken into account in sample size calculations to obtain the desired power. Our ICC estimates and sample size calculator will be useful for designing future trials that include twins. Publication of additional ICCs is needed to further assist with sample size planning for future trials. © 2018 John Wiley & Sons Ltd.
Liu, Lingyun; Wang, Wei; Zhang, Yi; Long, Jianting; Zhang, Zhaohui; Li, Qiao; Chen, Bin; Li, Shaoqiang; Hua, Yunpeng; Shen, Shunli; Peng, Baogang
2018-01-01
Purpose Various inflammation-based prognostic biomarkers such as the platelet to lymphocyte ratio and neutrophil to lymphocyte ratio, are related to poor survival in patients with intrahepatic cholangiocarcinoma (ICC). This study aims to investigate the prognostic value of the aspartate aminotransferase to neutrophil ratio index (ANRI) in ICC after hepatic resection. Materials and Methods Data of 184 patients with ICC after hepatectomy were retrospectively reviewed. The cut-off value of ANRIwas determined by a receiver operating characteristic curve. Preoperative ANRI and clinicopathological variables were analyzed. The predictive value of preoperative ANRI for prognosis of ICC was identified by univariate and multivariate analyses. Results The optimal cut-off value of ANRI was 6.7. ANRI was associated with tumor size, tumor recurrence, white blood cell, neutrophil count, aspartate aminotransferase, and alanine transaminase. Univariate analysis showed that ANRI, sex, tumor number, tumor size, tumor differentiation, lymph node metastasis, resection margin, clinical TNM stage, neutrophil count, and carcinoembryonic antigen were markedly correlated with overall survival (OS) and disease-free survival (DFS) in patients with ICC. Multivariable analyses revealed that ANRI, a tumor size > 6 cm, poor tumor differentiation, and an R1 resection margin were independent prognostic factors for both OS and DFS. Additionally, preoperative ANRI also had a significant value to predict prognosis in various subgroups of ICC, including serum hepatitis B surface antigen‒negative and preoperative elevated carbohydrate antigen 19-9 patients. Conclusion Preoperative declined ANRI is a noninvasive, simple, and effective predictor of poor prognosis in patients with ICC after hepatectomy. PMID:28602056
Czycholl, I; Kniese, C; Büttner, K; Beilage, E Grosse; Schrader, L; Krieter, J
2016-01-01
The present paper focuses on evaluating the interobserver reliability of the 'Welfare Quality(®) Animal Welfare Assessment Protocol for Growing Pigs'. The protocol for growing pigs mainly consists of a Qualitative Behaviour Assessment (QBA), direct behaviour observations (BO) carried out by instantaneous scan sampling and checks for different individual parameters (IP), e.g. presence of tail biting, wounds and bursitis. Three trained observers collected the data by performing 29 combined assessments, which were done at the same time and on the same animals; but they were carried out completely independent of each other. The findings were compared by the calculation of Spearman Rank Correlation Coefficients (RS), Intraclass Correlation Coefficients (ICC), Smallest Detectable Changes (SDC) and Limits of Agreements (LoA). There was no agreement found concerning the adjectives belonging to the QBA (e.g. active: RS: 0.50, ICC: 0.30, SDC: 0.38, LoA: -0.05 to 0.45; fearful: RS: 0.06, ICC: 0.0, SDC: 0.26, LoA: -0.20 to 0.30). In contrast, the BO showed good agreement (e.g. social behaviour: RS: 0.45, ICC: 0.50, SDC: 0.09, LoA: -0.09 to 0.03 use of enrichment material: RS: 0.75, ICC: 0.68, SDC: 0.06, LoA: -0.03 to 0.03). Overall, observers agreed well in the IP, e.g. tail biting (RS: 0.52, ICC: 0.88; SDC: 0.05, LoA: -0.01 to 0.02) and wounds (RS: 0.43, ICC: 0.59, SDC: 0.10, LoA: -0.09 to 0.10). The parameter bursitis showed great differences (RS: 0.10, ICC: 0.0, SDC: 0.35, LoA: -0.37 to 0.40), which can be explained by difficulties in the assessment when the animals moved around quickly or their legs were soiled. In conclusion, the interobserver reliability was good in the BO and most IP, but not for the parameter bursitis and the QBA.
Precision analysis of a quantitative CT liver surface nodularity score.
Smith, Andrew; Varney, Elliot; Zand, Kevin; Lewis, Tara; Sirous, Reza; York, James; Florez, Edward; Abou Elkassem, Asser; Howard-Claudio, Candace M; Roda, Manohar; Parker, Ellen; Scortegagna, Eduardo; Joyner, David; Sandlin, David; Newsome, Ashley; Brewster, Parker; Lirette, Seth T; Griswold, Michael
2018-04-26
To evaluate precision of a software-based liver surface nodularity (LSN) score derived from CT images. An anthropomorphic CT phantom was constructed with simulated liver containing smooth and nodular segments at the surface and simulated visceral and subcutaneous fat components. The phantom was scanned multiple times on a single CT scanner with adjustment of image acquisition and reconstruction parameters (N = 34) and on 22 different CT scanners from 4 manufacturers at 12 imaging centers. LSN scores were obtained using a software-based method. Repeatability and reproducibility were evaluated by intraclass correlation (ICC) and coefficient of variation. Using abdominal CT images from 68 patients with various stages of chronic liver disease, inter-observer agreement and test-retest repeatability among 12 readers assessing LSN by software- vs. visual-based scoring methods were evaluated by ICC. There was excellent repeatability of LSN scores (ICC:0.79-0.99) using the CT phantom and routine image acquisition and reconstruction parameters (kVp 100-140, mA 200-400, and auto-mA, section thickness 1.25-5.0 mm, field of view 35-50 cm, and smooth or standard kernels). There was excellent reproducibility (smooth ICC: 0.97; 95% CI 0.95, 0.99; CV: 7%; nodular ICC: 0.94; 95% CI 0.89, 0.97; CV: 8%) for LSN scores derived from CT images from 22 different scanners. Inter-observer agreement for the software-based LSN scoring method was excellent (ICC: 0.84; 95% CI 0.79, 0.88; CV: 28%) vs. good for the visual-based method (ICC: 0.61; 95% CI 0.51, 0.69; CV: 43%). Test-retest repeatability for the software-based LSN scoring method was excellent (ICC: 0.82; 95% CI 0.79, 0.84; CV: 12%). The software-based LSN score is a quantitative CT imaging biomarker with excellent repeatability, reproducibility, inter-observer agreement, and test-retest repeatability.
Assessment of the amount of tooth wear on dental casts and intra-oral photographs.
Wetselaar, P; Wetselaar-Glas, M J M; Koutris, M; Visscher, C M; Lobbezoo, F
2016-08-01
Tooth wear is a multifactorial condition, leading to the loss of dental hard tissues. Many grading scales are available to assess the amount of tooth wear, one of which is the tooth wear evaluation system (TWES). A grading scale can be used chairside, on casts and on photographs. The aim was to test whether the grading scales of the TWES, used on casts and on photographs, resulted in comparable scores. In addition, it was tested whether these scales can be used to assess tooth wear reliably on photographs. Of 75 tooth wear patients, sets of casts and series of photographs were obtained and graded. Comparison of the grading on casts and on photographs revealed equal median values and percentiles for both occlusal/incisal grading and non-occlusal/non-incisal grading. The grading on casts and on photographs showed a high correlation for the occlusal/incisal grading and a low correlation for the non-occlusal/non-incisal grading (Spearman's rho = 0·74 and rho = 0·47; P < 0·001). Concerning the grading on photographs, the interexaminer reliability was fair-to-good (ICC = 0·41 to ICC = 0·55) while the intra-examiner reliability was fair-to-good to excellent (ICC = 0·68 to ICC = 0·86) for the occlusal/incisal grading. For the non-occlusal/non-incisal grading, the interexaminer reliability was poor to fair-to-good (ICC = 0·22 to ICC = 0·59), while the intra-examiner reliability was fair-to-good to excellent (ICC = 0·64 to ICC = 0·82). It was concluded that the scores obtained with the grading scales of the TWES on casts and on photographs are comparable. The grading scales can be used in a reliable way on photographs, which is especially the case for occlusal/incisal grading. © 2016 John Wiley & Sons Ltd.
Prowse, Ashleigh; Aslaksen, Berit; Kierkegaard, Marie; Furness, James; Gerdhem, Paul; Abbott, Allan
2017-01-01
AIM To investigate the reliability and concurrent validity of the Baseline® Body Level/Scoliosis meter for adolescent idiopathic scoliosis postural assessment in three anatomical planes. METHODS This is an observational reliability and concurrent validity study of adolescent referrals to the Orthopaedic department for scoliosis screening at Karolinska University Hospital, Stockholm, Sweden between March-May 2012. A total of 31 adolescents with idiopathic scoliosis (13.6 ± 0.6 years old) of mild-moderate curvatures (25° ± 12°) were consecutively recruited. Measurement of cervical, thoracic and lumbar curvatures, pelvic and shoulder tilt, and axial thoracic rotation (ATR) were performed by two trained physiotherapists in one day. The intraclass correlation coefficient (ICC) was used to determine the inter-examiner reliability (ICC2,1) and the intra-rater reliability (ICC3,3) of the Baseline® Body Level/Scoliosis meter. Spearman’s correlation analyses were used to estimate concurrent validity between the Baseline® Body Level/Scoliosis meter and Gold Standard Cobb angles from radiographs and the Orthopaedic Systems Inc. Scoliometer. RESULTS There was excellent reliability between examiners for thoracic kyphosis (ICC2,1 = 0.94), ATR (ICC2,1 = 0.92) and lumbar lordosis (ICC2,1 = 0.79). There was adequate reliability between examiners for cervical lordosis (ICC2,1 = 0.51), however poor reliability for pelvic and shoulder tilt. Both devices were reproducible in the measurement of ATR when repeated by one examiner (ICC3,3 0.98-1.00). The device had a good correlation with the Scoliometer (rho = 0.78). When compared with Cobb angle from radiographs, there was a moderate correlation for ATR (rho = 0.627). CONCLUSION The Baseline® Body Level/Scoliosis meter provides reliable transverse and sagittal cervical, thoracic and lumbar measurements and valid transverse plan measurements of mild-moderate scoliosis deformity. PMID:28144582
Sousa, Filipe Antônio Barros; Vasque, Rubens Eduardo; Gobatto, Claudio Alexandre
2017-01-01
This study's aims to verify the energy expenditure, metabolic distress and usefulness to evaluate the anaerobic constructs for different all-out durations in running efforts. Twelve active male underwent four testing sessions, one for familiarization and three performing one all-out (AO) tethered running sprint lasting 30s, 20s or 10s. Oxygen consumption, excess post exercise oxygen consumption, and lactate production were retained to analyse metabolic function, together with mechanical power and work as performance parameters. Paired results were compared via one-way ANOVA for repeated measures (Tukey-HSD post-hoc), effect sizes and ICC for absolute agreement. Statistical significance was accepted at p ≤ 0.05. Despite total and energy expenditure from oxidative pathway being significantly higher for longer durations (p < 0.001; ES > 0.7), glycolytic energy expenditure presented an agreement between AO30s and AO20s (ICC-A = 0.63*), while the paired comparisons to AO10s have presented significant differences (p < 0.01; ES > 1.0). Phosphagen energy expenditure were similar between all-out durations (p = 0.12; ICC-A = 0.62*; ES < 0.5). Maximum mechanical power was higher in AO10s than in AO30s (p = 0.03; ES = 0.6), not being different between AO10s and AO20s (p = 0.67; ICC-A = 0.88*; ES = 0.2) and between AO20s and AO30s (p = 0.18; ICC-A = 0.56*; ES = 0.4). In addition, agreement between work in the first ten seconds was confirmed via ICC only between AO10s and AO20s (p = 0.50; ICC-A = 0.86*; ES = 0.3), but not for the other paired comparisons (p < 0.1; ICC < 0.45; ES > 0.5). AO20s is a better alternative to estimate anaerobic power and capacity in one single test, with similar oxidative demand than AO30s.
Welzel, Tania M; Graubard, Barry I; Zeuzem, Stefan; El-Serag, Hashem B; Davila, Jessica A; McGlynn, Katherine A
2011-08-01
Incidence rates of hepatocellular carcinoma (HCC) and intrahepatic cholangiocarcinoma (ICC) have increased in the United States. Metabolic syndrome is recognized as a risk factor for HCC and a postulated one for ICC. The magnitude of risk, however, has not been investigated on a population level in the United States. We therefore examined the association between metabolic syndrome and the development of these cancers. All persons diagnosed with HCC and ICC between 1993 and 2005 were identified in the Surveillance, Epidemiology, and End Results (SEER)-Medicare database. For comparison, a 5% sample of individuals residing in the same regions as the SEER registries of the cases was selected. The prevalence of metabolic syndrome as defined by the U.S. National Cholesterol Education Program Adult Treatment Panel III criteria, and other risk factors for HCC (hepatitis B virus, hepatitis C virus, alcoholic liver disease, liver cirrhosis, biliary cirrhosis, hemochromatosis, Wilson's disease) and ICC (biliary cirrhosis, cholangitis, cholelithiasis, choledochal cysts, hepatitis B virus, hepatitis C virus, alcoholic liver disease, cirrhosis, inflammatory bowel disease) were compared among persons who developed cancer and those who did not. Logistic regression was used to calculate odds ratios and 95% confidence intervals. The inclusion criteria were met by 3649 HCC cases, 743 ICC cases, and 195,953 comparison persons. Metabolic syndrome was significantly more common among persons who developed HCC (37.1%) and ICC (29.7%) than the comparison group (17.1%, P<0.0001). In adjusted multiple logistic regression analyses, metabolic syndrome remained significantly associated with increased risk of HCC (odds ratio=2.13; 95% confidence interval=1.96-2.31, P<0.0001) and ICC (odds ratio=1.56; 95% confidence interval=1.32-1.83, P<0.0001). Metabolic syndrome is a significant risk factor for development of HCC and ICC in the general U.S. population. Copyright © 2011 American Association for the Study of Liver Diseases.
Reproducibility of urinary biomarkers in multiple 24-h urine samples.
Sun, Qi; Bertrand, Kimberly A; Franke, Adrian A; Rosner, Bernard; Curhan, Gary C; Willett, Walter C
2017-01-01
Limited knowledge regarding the reproducibility of biomarkers in 24-h urine samples has hindered the collection and use of the samples in epidemiologic studies. We aimed to evaluate the reproducibility of various markers in repeat 24-h urine samples. We calculated intraclass correlation coefficients (ICCs) of biomarkers measured in 24-h urine samples that were collected in 3168 participants in the NHS (Nurses' Health Study), NHSII (Nurses' Health Study II), and Health Professionals Follow-Up Study. In 742 women with 4 samples each collected over the course of 1 y, ICCs for sodium were 0.32 in the NHS and 0.34 in the NHSII. In 2439 men and women with 2 samples each collected over 1 wk to ≥1 mo, the ICCs ranged from 0.33 to 0.68 for sodium at various intervals between collections. The urinary excretion of potassium, calcium, magnesium, phosphate, sulfate, and other urinary markers showed generally higher reproducibility (ICCs >0.4). In 47 women with two 24-h urine samples, ICCs ranged from 0.15 (catechin) to 0.75 (enterolactone) for polyphenol metabolites. For phthalates, ICCs were generally ≤0.26 except for monobenzyl phthalate (ICC: 0.55), whereas the ICC was 0.39 for bisphenol A (BPA). We further estimated that, for the large majority of the biomarkers, the mean of three 24-h urine samples could provide a correlation of ≥0.8 with true long-term urinary excretion. These data suggest that the urinary excretion of various biomarkers, such as minerals, electrolytes, most polyphenols, and BPA, is reasonably reproducible in 24-h urine samples that are collected within a few days or ≤1 y. Our findings show that three 24-h samples are sufficient for the measurement of long-term exposure status in epidemiologic studies. © 2017 American Society for Nutrition.
Nixon, Mark S.; Komogortsev, Oleg V.
2017-01-01
We introduce the intraclass correlation coefficient (ICC) to the biometric community as an index of the temporal persistence, or stability, of a single biometric feature. It requires, as input, a feature on an interval or ratio scale, and which is reasonably normally distributed, and it can only be calculated if each subject is tested on 2 or more occasions. For a biometric system, with multiple features available for selection, the ICC can be used to measure the relative stability of each feature. We show, for 14 distinct data sets (1 synthetic, 8 eye-movement-related, 2 gait-related, and 2 face-recognition-related, and one brain-structure-related), that selecting the most stable features, based on the ICC, resulted in the best biometric performance generally. Analyses based on using only the most stable features produced superior Rank-1-Identification Rate (Rank-1-IR) performance in 12 of 14 databases (p = 0.0065, one-tailed), when compared to other sets of features, including the set of all features. For Equal Error Rate (EER), using a subset of only high-ICC features also produced superior performance in 12 of 14 databases (p = 0. 0065, one-tailed). In general, then, for our databases, prescreening potential biometric features, and choosing only highly reliable features yields better performance than choosing lower ICC features or than choosing all features combined. We also determined that, as the ICC of a group of features increases, the median of the genuine similarity score distribution increases and the spread of this distribution decreases. There was no statistically significant similar relationships for the impostor distributions. We believe that the ICC will find many uses in biometric research. In case of the eye movement-driven biometrics, the use of reliable features, as measured by ICC, allowed to us achieve the authentication performance with EER = 2.01%, which was not possible before. PMID:28575030
Friedman, Lee; Nixon, Mark S; Komogortsev, Oleg V
2017-01-01
We introduce the intraclass correlation coefficient (ICC) to the biometric community as an index of the temporal persistence, or stability, of a single biometric feature. It requires, as input, a feature on an interval or ratio scale, and which is reasonably normally distributed, and it can only be calculated if each subject is tested on 2 or more occasions. For a biometric system, with multiple features available for selection, the ICC can be used to measure the relative stability of each feature. We show, for 14 distinct data sets (1 synthetic, 8 eye-movement-related, 2 gait-related, and 2 face-recognition-related, and one brain-structure-related), that selecting the most stable features, based on the ICC, resulted in the best biometric performance generally. Analyses based on using only the most stable features produced superior Rank-1-Identification Rate (Rank-1-IR) performance in 12 of 14 databases (p = 0.0065, one-tailed), when compared to other sets of features, including the set of all features. For Equal Error Rate (EER), using a subset of only high-ICC features also produced superior performance in 12 of 14 databases (p = 0. 0065, one-tailed). In general, then, for our databases, prescreening potential biometric features, and choosing only highly reliable features yields better performance than choosing lower ICC features or than choosing all features combined. We also determined that, as the ICC of a group of features increases, the median of the genuine similarity score distribution increases and the spread of this distribution decreases. There was no statistically significant similar relationships for the impostor distributions. We believe that the ICC will find many uses in biometric research. In case of the eye movement-driven biometrics, the use of reliable features, as measured by ICC, allowed to us achieve the authentication performance with EER = 2.01%, which was not possible before.
Reproducibility of urinary biomarkers in multiple 24-h urine samples123
Sun, Qi; Bertrand, Kimberly A; Franke, Adrian A; Rosner, Bernard; Curhan, Gary C; Willett, Walter C
2017-01-01
Background: Limited knowledge regarding the reproducibility of biomarkers in 24-h urine samples has hindered the collection and use of the samples in epidemiologic studies. Objective: We aimed to evaluate the reproducibility of various markers in repeat 24-h urine samples. Design: We calculated intraclass correlation coefficients (ICCs) of biomarkers measured in 24-h urine samples that were collected in 3168 participants in the NHS (Nurses’ Health Study), NHSII (Nurses’ Health Study II), and Health Professionals Follow-Up Study. Results: In 742 women with 4 samples each collected over the course of 1 y, ICCs for sodium were 0.32 in the NHS and 0.34 in the NHSII. In 2439 men and women with 2 samples each collected over 1 wk to ≥1 mo, the ICCs ranged from 0.33 to 0.68 for sodium at various intervals between collections. The urinary excretion of potassium, calcium, magnesium, phosphate, sulfate, and other urinary markers showed generally higher reproducibility (ICCs >0.4). In 47 women with two 24-h urine samples, ICCs ranged from 0.15 (catechin) to 0.75 (enterolactone) for polyphenol metabolites. For phthalates, ICCs were generally ≤0.26 except for monobenzyl phthalate (ICC: 0.55), whereas the ICC was 0.39 for bisphenol A (BPA). We further estimated that, for the large majority of the biomarkers, the mean of three 24-h urine samples could provide a correlation of ≥0.8 with true long-term urinary excretion. Conclusions: These data suggest that the urinary excretion of various biomarkers, such as minerals, electrolytes, most polyphenols, and BPA, is reasonably reproducible in 24-h urine samples that are collected within a few days or ≤1 y. Our findings show that three 24-h samples are sufficient for the measurement of long-term exposure status in epidemiologic studies. PMID:28049663
PREFACE: 3rd International Congress on Ceramics (ICC3)
NASA Astrophysics Data System (ADS)
Niihara, Koichi; Ohji, Tatsuki; Sakka, Yoshio
2011-10-01
Early in 2005, the American Ceramic Society, the European Ceramic Society and the Ceramic Society of Japan announced a collaborative effort to provide leadership for the global ceramics community that would facilitate the use of ceramic and glass materials. That effort resulted in an agreement to organize a new biennial series of the International Congress on Ceramics, convened by the International Ceramic Federation (ICF). In order to share ideas and visions of the future for ceramic and glass materials, the 1st International Congress on Ceramics (ICC1) was held in Canada, 2006, under the organization of the American Ceramic Society, and the 2nd Congress (ICC2) was held in Italy, 2008, hosted by the European Ceramic Society. Organized by the Ceramic Society of Japan, the 3rd Congress (ICC3) was held in Osaka, Japan, 14-18 November 2010. Incorporating the 23rd Fall Meeting of the Ceramic Society of Japan and the 20th Iketani Conference, ICC3 was also co-organized by the Iketani Science and Technology Foundation, and was endorsed and supported by ICF, Asia-Oceania Ceramic Federation (AOCF) as well as many other organizations. Following the style of the previous two successful Congresses, the program was designed to advance ceramic and glass technologies to the next generation through discussion of the most recent advances and future perspectives, and to engage the worldwide ceramics community in a collective effort to expand the use of these materials in both conventional as well as new and exciting applications. ICC3 consisted of 22 voluntarily organized symposia in the most topical and essential themes of ceramic and glass materials, including Characterization, design and processing technologies Electro, magnetic and optical ceramics and devices Energy and environment related ceramics and systems Bio-ceramics and bio-technologies Ceramics for advanced industry and safety society Innovation in traditional ceramics It also contained the Plenary Session and the Special Symposium 'Emerging Technologies and Future Aspects for Ceramics', which discussed the issues and challenges of various ceramic technologies for sustainable development of tomorrow's human society. More than 1850 research papers including invited talks, oral presentations, and posters were presented from 56 countries (according to the Program), with nearly 2000 registered participants. This ICC3 proceedings contains papers that were submitted to ICC3 and approved for publication on line in IOP Conference Series: Materials Science and Engineering (MSE). The organization of ICC3 and the publication of this proceedings were made possible thanks to the tireless dedication of many people and the valuable support of numerous bodies. Special thanks should go to the financial supporters for their generous patronage. We also would like to express our sincere thanks to the symposia organizers, session chairs, presenters, exhibitors and congress attendees for their efforts and enthusiastic participation in this vibrant and cutting-edge congress. July 2011 Koichi Niihara, ICC3 President Tatsuki Ohji, ICC3 Secretariat Yoshio Sakka, ICC3 Secretariat The PDF file contains a complete list of sponsors, committee members, board members and symposia organizers.
Serrano, Beatriz; Alemany, Laia; Ruiz, Patricia Alonso de; Tous, Sara; Lima, Marcus Aurelho; Bruni, Laia; Jain, Asha; Clifford, Gary M; Qiao, You Lin; Weiss, Thomas; Bosch, F Xavier; de Sanjosé, Silvia
2014-12-01
We estimated the potential impact of an investigational 9-valent human papillomavirus (HPV) vaccine (HPVs 6/11/16/18/31/33/45/52/58) in HPV-related cervical disease in Brazil, Mexico, India and China, to help to formulate recommendations on cervical cancer prevention and control. Estimations for invasive cervical cancer (ICC) were based on an international study including 1356 HPV-positive cases for the four countries altogether, and estimations for precancerous cervical lesions were extracted from a published meta-analysis including 6 025 HPV-positive women from the four mentioned countries. Globocan 2012 and 2012 World Population Prospects were used to estimate current and future projections of new ICC cases. Combined proportions of the 9 HPV types in ICC were 88.6% (95%CI: 85.2-91.3) in Brazil, 85.7% (82.3-88.8) in Mexico, 92.2% (87.9-95.3) in India and 97.3% (93.9-99.1) in China. The additional HPV 31/33/45/52/58 proportions were 18.8% (15.3-22.7) in Brazil, 17.6% (14.2-21.2) in Mexico, 11.3% (7.5-16.1) in India and 11.9% (7.5-17.2) in China. HPV6 and 11 single types were not identified in any of the samples. Proportion of the individual 7 high risk HPV types included in the vaccine varied by cytological and histological grades of HPV-positive precancerous cervical lesions. HPV 16 was the dominant type in all lesions, with contributions in low grade lesions ranging from 16.6%(14.3-19.2) in Mexico to 39.8% (30.0-50.2) in India, and contributions in high grade lesions ranging from 43.8% (36.3-51.4) in Mexico to 64.1% (60.6-67.5) in Brazil. After HPV 16, variations in other majors HPV types were observed by country, with an under representation of HPV 18 and 45 compared to ICC. The addition of HPVs 31/33/45/52/58 to HPV types included in current vaccines could increase the ICC preventable fraction in a range of 12 to 19% across the four countries, accounting the 9-types altogether 90% of ICC cases. Assuming the same degree of efficacy of current vaccines, the implementation of the 9-valent HPV vaccine in Brazil, Mexico, India and China would substantially impact on the reduction of the world cervical cancer burden. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
Comparing Audio and Video Data for Rating Communication
Williams, Kristine; Herman, Ruth; Bontempo, Daniel
2013-01-01
Video recording has become increasingly popular in nursing research, adding rich nonverbal, contextual, and behavioral information. However, benefits of video over audio data have not been well established. We compared communication ratings of audio versus video data using the Emotional Tone Rating Scale. Twenty raters watched video clips of nursing care and rated staff communication on 12 descriptors that reflect dimensions of person-centered and controlling communication. Another group rated audio-only versions of the same clips. Interrater consistency was high within each group with ICC (2,1) for audio = .91, and video = .94. Interrater consistency for both groups combined was also high with ICC (2,1) for audio and video = .95. Communication ratings using audio and video data were highly correlated. The value of video being superior to audio recorded data should be evaluated in designing studies evaluating nursing care. PMID:23579475
2000-03-21
KENNEDY SPACE CENTER, FLA. -- At Launch Pad 39A, the payload canister with the SPACEHAB Double Module and the Integrated Cargo Carrier (ICC) inside is lifted off the payload transporter toward the Payload Changeout Room (PCR) on the Rotating Service Structure (RSS). The PCR is an environmentally controlled facility supporting cargo delivery to the pad and vertical installation in the orbiter cargo bay. At right of the RSS is the Fixed Service Structure. The primary payloads on mission STS-101, the module and ICC contain internal logistics and resupply cargo for restoring full redundancy to the International Space Station power system in preparation for the arrival of the next pressurized module, the Russian-built Zvezda. The payloads will be transferred to Space Shuttle Atlantis after Atlantis rolls out to the pad. Launch of Atlantis on mission STS-101 is scheduled no earlier than April 17, 2000
2000-03-21
KENNEDY SPACE CENTER, FLA. -- At Launch Pad 39A, the payload canister with the SPACEHAB Double Module and Integrated Cargo Carrier (ICC) inside is lifted up the Rotating Service Structure (RSS) toward the Payload Changeout Room, an environmentally controlled facility supporting cargo delivery to the pad and vertical installation in the orbiter cargo bay. At right of the RSS is the Fixed Service Structure, topped by the 80-foot-tall fiberglass lightning mast. The primary payload on mission STS-101, the module and ICC contain internal logistics and resupply cargo for restoring full redundancy to the International Space Station power system in preparation for the arrival of the next pressurized module, the Russian-built Zvezda. The payloads will be transferred to Space Shuttle Atlantis after Atlantis rolls out to the pad. Launch of Atlantis on mission STS-101 is scheduled no earlier than April 17, 2000
2000-03-21
KENNEDY SPACE CENTER, FLA. -- At Launch Pad 39A, the payload canister with the SPACEHAB Double Module and Integrated Cargo Carrier (ICC) inside is lifted up the Rotating Service Structure (RSS) toward the Payload Changeout Room, an environmentally controlled facility supporting cargo delivery to the pad and vertical installation in the orbiter cargo bay. At right of the RSS is the Fixed Service Structure, topped by the 80-foot-tall fiberglass lightning mast. The primary payload on mission STS-101, the module and ICC contain internal logistics and resupply cargo for restoring full redundancy to the International Space Station power system in preparation for the arrival of the next pressurized module, the Russian-built Zvezda. The payloads will be transferred to Space Shuttle Atlantis after Atlantis rolls out to the pad. Launch of Atlantis on mission STS-101 is scheduled no earlier than April 17, 2000
2000-03-21
KENNEDY SPACE CENTER, FLA. -- At Launch Pad 39A, the payload canister with the SPACEHAB Double Module and the Integrated Cargo Carrier (ICC) inside is lifted off the payload transporter toward the Payload Changeout Room (PCR) on the Rotating Service Structure (RSS). The PCR is an environmentally controlled facility supporting cargo delivery to the pad and vertical installation in the orbiter cargo bay. At right of the RSS is the Fixed Service Structure. The primary payloads on mission STS-101, the module and ICC contain internal logistics and resupply cargo for restoring full redundancy to the International Space Station power system in preparation for the arrival of the next pressurized module, the Russian-built Zvezda. The payloads will be transferred to Space Shuttle Atlantis after Atlantis rolls out to the pad. Launch of Atlantis on mission STS-101 is scheduled no earlier than April 17, 2000
Abraham, Alison G; Strickler, Howard D; Jing, Yuezhou; Gange, Stephen J; Sterling, Timothy R; Silverberg, Michael; Saag, Michael; Rourke, Sean; Rachlis, Anita; Napravnik, Sonia; Moore, Richard D; Klein, Marina; Kitahata, Mari; Kirk, Greg; Hogg, Robert; Hessol, Nancy A; Goedert, James J; Gill, M John; Gebo, Kelly; Eron, Joseph J; Engels, Eric A; Dubrow, Robert; Crane, Heidi M; Brooks, John T; Bosch, Ronald; D’Souza, Gypsyamber
2013-01-01
Objective HIV infection and low CD4+ T-cell count are associated with an increased risk of persistent oncogenic HPV infection – the major risk factor for cervical cancer. Few reported prospective cohort studies have characterized the incidence of invasive cervical cancer (ICC) in HIV-infected women. Methods Data were obtained from HIV-infected and -uninfected female participants in the NA-ACCORD with no history of ICC at enrollment. Participants were followed from study entry or January, 1996 through ICC, loss-to follow-up or December, 2010. The relationship of HIV infection and CD4+ T-cell count with risk of ICC was assessed using age-adjusted Poisson regression models and standardized incidence ratios (SIR). All cases were confirmed by cancer registry records and/or pathology reports. Cervical cytology screening history was assessed through medical record abstraction. Results A total of 13,690 HIV-infected and 12,021 HIV-uninfected women contributed 66,249 and 70,815 person-years (pys) of observation, respectively. Incident ICC was diagnosed in 17 HIV-infected and 4 HIV-uninfected women (incidence rate of 26 and 6 per 100,000 pys, respectively). HIV-infected women with baseline CD4+ T-cells of ≥ 350, 200–349 and <200 cells/uL had a 2.3-times, 3.0-times and 7.7-times increase in ICC incidence, respectively, compared with HIV-uninfected women (Ptrend =0.001). Of the 17 HIV-infected cases, medical records for the 5 years prior to diagnosis showed that 6 had no documented screening, 5 had screening with low grade or normal results, and 6 had high-grade results. Conclusions This study found elevated incidence of ICC in HIV-infected compared to -uninfected women, and these rates increased with immunosuppression. PMID:23254153
Mendis, M Dilani; Wilson, Stephen J; Stanton, Warren; Hides, Julie A
2010-09-01
Clinical measurement, criterion standard. To investigate the validity of real-time ultrasound imaging (USI) to measure individual anterior hip muscle cross-sectional area. The hip flexor muscles are important for hip joint function and could be affected by joint pathology or injury. Objectively documenting individual anterior hip muscle size can be useful in identifying muscle size asymmetry and monitoring treatment efficacy for patients with hip problems. USI offers a novel method of measuring individual muscle size in the clinic, but its validity in measuring the anterior hip muscles has not been investigated. Nine healthy participants (5 males, 4 females) underwent imaging of their iliopsoas, sartorius, and rectus femoris muscles with USI and magnetic resonance imaging. Bilateral muscle cross-sectional areas were measured on images from both modalities. There was no significant difference (P>.05) in mean cross-sectional area measurements from USI and magnetic resonance imaging for each muscle. Agreement between measurements was high for the iliopsoas (left: intraclass correlation coefficient [ICC3,1] = 0.86; 95% confidence interval [CI]: 0.51, 0.97; right: ICC3,1 = 0.88; 95% CI: 0.57, 0.97), sartorius (left: ICC3,1 = 0.82; 95% CI: 0.41, 0.96; right: ICC3,1 = 0.81; 95% CI: 0.39, 0.95), and rectus femoris (left: ICC3,1 = 0.85; 95% CI: 0.49, 0.96; right: ICC3,1 = 0.89; 95% CI: 0.61, 0.97). Reliability of measuring each muscle with USI was high between 2 trials (ICCs3,1 = 0.84 to 0.94). USI is a valid measure of iliopsoas, sartorius, and rectus femoris muscle size in healthy people, as long as a strict measurement protocol is followed.
Gao, Yuanyuan; Yang, Michelle; Jiang, Zhong; Woda, Bruce A; Mercurio, Arthur M; Qin, Jianjie; Huang, Xinli; Zhang, Feng
2014-06-01
IMP3 is a fetal protein not expressed in normal adult tissues. IMP3 is an oncoprotein and a useful biomarker for a variety of malignancies and is associated with reduced overall survival of a number of them. IMP3 expression and its prognostic value for patients with intrahepatic cholangiocarcinoma (ICC) have not been well investigated. The molecular mechanism underlying IMP3 expression in human cancer cells remains to be elucidated. Here we investigated IMP3 expression in ICC and adjacent nonneoplastic liver in 72 unifocal primary ICCs from a single institute by immunohistochemistry, immunoblotting, and real-time polymerase chain reaction. IMP3 was specifically expressed in cancer cells but not in the surrounding normal tissue, and 59 (82%) of 72 ICCs were IMP3 positive by immunohistochemistry. Among 35 cases with lymphovascular invasion, 26 (74%) showed IMP3 positivity in lymph node metastases. IMP3 expression was significantly correlated with tumor size, pathological grade, metastasis, and clinical stage. Kaplan-Meier analysis demonstrated an inverse correlation between IMP3 expression and overall survival rate. Multivariate analysis revealed that IMP3 was the only risk factor associated with survival. To further explore the mechanism of IMP3 expression in cancers, we identified 2 CpG islands at IMP3 proximal promoter. Interestingly, the IMP3 promoter was almost completely demethylated in ICCs in contrast to densely methylated promoter in normal liver tissues. IMP3 expression is a useful biomarker for ICCs and can provide an independent prognostic value for patients with ICC. To our knoweldge, this is the first direct evidence of epigenetic deregulation of IMP3 in human cancer. Copyright © 2014 The Auhtors. Published by Elsevier Inc. All rights reserved.
Bretas, Elisa Almeida Sathler; Torres, Ulysses S; Torres, Lucas Rios; Bekhor, Daniel; Saito Filho, Celso Fernando; Racy, Douglas Jorge; Faggioni, Lorenzo; D'Ippolito, Giuseppe
2017-10-01
To evaluate the agreement between the measurements of perfusion CT parameters in normal livers by using two different software packages. This retrospective study was based on 78 liver perfusion CT examinations acquired for detecting suspected liver metastasis. Patients with any morphological or functional hepatic abnormalities were excluded. The final analysis included 37 patients (59.7 ± 14.9 y). Two readers (1 and 2) independently measured perfusion parameters using different software packages from two major manufacturers (A and B). Arterial perfusion (AP) and portal perfusion (PP) were determined using the dual-input vascular one-compartmental model. Inter-reader agreement for each package and intrareader agreement between both packages were assessed with intraclass correlation coefficients (ICC) and Bland-Altman statistics. Inter-reader agreement was substantial for AP using software A (ICC = 0.82) and B (ICC = 0.85-0.86), fair for PP using software A (ICC = 0.44) and fair to moderate for PP using software B (ICC = 0.56-0.77). Intrareader agreement between software A and B ranged from slight to moderate (ICC = 0.32-0.62) for readers 1 and 2 considering the AP parameters, and from fair to moderate (ICC = 0.40-0.69) for readers 1 and 2 considering the PP parameters. At best there was only moderate agreement between both software packages, resulting in some uncertainty and suboptimal reproducibility. Advances in knowledge: Software-dependent factors may contribute to variance in perfusion measurements, demanding further technical improvements. AP measurements seem to be the most reproducible parameter to be adopted when evaluating liver perfusion CT.
Becker, Anton S; Cornelius, Alexander; Reiner, Cäcilia S; Stocker, Daniel; Ulbrich, Erika J; Barth, Borna K; Mortezavi, Ashkan; Eberli, Daniel; Donati, Olivio F
2017-09-01
to simultaneously evaluate interreader agreement and diagnostic accuracy in the of PI-RADS v2 and compare it to v1. A total of 67 patients (median age 65.3 y, range 51.2-78.2 y; PSA 6.8μg/L, 0.2-33μg/L) undergoing MRI of the prostate and subsequent transperineal template biopsy within ≤6 months from MRI were included. Four readers from two institutions evaluated the likelihood of prostate cancer using PI-RADS v1 and v2 in two separate reading sessions ≥3 months apart. Interreader agreement was assessed for each pulse-sequence and for total PI-RADS scores using the intraclass correlation coefficient (ICC). Differences were considered significant for non-overlapping 95%-confidence intervals. Diagnostic accuracy was assessed with the area under the receiver operating characteristic curve (A Z ). A p-value <0.05 was considered statistically significant. Interreader agreement for DCE-scores was good in v2 (ICC 2 =0.70; 95% CI: 0.66-0.74) and slightly lower in v1 (ICC 1 =0.64, 0.59-0.69). Agreement for DWI scores (ICC 1 =0.77, ICC 2 =0.76) as well as final PI-RADS scores per quadrant were nearly identical (ICC 1 =ICC 2 =0.71). Diagnostic accuracy showed no significant differences (p=0.09-0.93) between v1 and v2 in any of the readers (range: A Z =0.78-0.88). PI-RADS scores show similar interreader agreement in v2 and v1 at comparable diagnostic performance. The simplification of the DCE interpretation in v2 might slightly improve agreement while not negatively affecting diagnostic performance. Copyright © 2017 Elsevier B.V. All rights reserved.
Lui, P Priscilla
2015-03-01
Among immigrant Asian and Latino groups, the contrast between collectivism in traditional heritage and individualism in the mainstream American cultures presents unique challenges for their family relationships. This systematic review was designed to answer 3 fundamental questions: to what extent do(es) (a) acculturation mismatch (AM) correlate with intergenerational cultural conflict (ICC); (b) ICC correlate with offspring's mental health and educational outcomes; and (c) demographic and study characteristics moderate these relationships. Sixty-one research reports were reviewed, with 68 independent study samples (N = 14,453; 41 and 27 Asian and Latino/a samples, respectively) subjected to 3 meta-analyses. AM positively correlated with ICC (r = .23), which in turn negatively correlated with offspring mental health (r = -.20) and educational outcomes (r = -.09). Findings provided support for acculturation gap-distress theory. While these effect size estimates were small, participant and methodological variables affected their magnitude. Contrary to findings on intergenerational conflict within mainstream non-immigrant families, the relationships among AM, ICC, and mental health were larger in young adult than adolescent groups within immigrant families. ICC significantly correlated with internalizing problems and adaptive functioning, but not externalizing problems. AM was more closely related to ICC among women and second-generation immigrant offspring. AM and ICC were more problematic among offspring who were low-risk and lived in less ethnically disperse regions, particularly when studied in cross-sectional studies. Effect sizes also differed significantly across measurement tools for the key constructs. Limitations to generalizability (few studies on educational outcomes, relative under-representation of Latino/a to Asian American samples), and implications for intervention and future research are discussed. PsycINFO Database Record (c) 2015 APA, all rights reserved.
Cipriani, G; Serboiu, Crenguta S; Gherghiceanu, Mihaela; Simonetta Faussone-Pellegrini, Maria; Vannucchi, Maria Giuliana
2011-01-01
Abstract Caveolin (Cav)-1 is an integral membrane protein of caveolae playing a crucial role in various signal transduction pathways. Caveolae represent the sites for calcium entry and storage especially in smooth muscle cells (SMC) and interstitial cells of Cajal (ICC). Cav-1−/− mice lack caveolae and show abnormalities in pacing and contractile activity of the small intestine. Presently, we investigated, by transmission electron microscopy (TEM) and immunohistochemistry, whether the absence of Cav-1 in Cav-1−/− mouse small intestine affects ICC, SMC and neuronal morphology, the expression of NK1 and NK2 receptors, and of Ano1 (also called Dog1 or TMEM16A), an essential molecule for slow wave activity in gastrointestinal muscles. ICC were also labelled with c-Kit and tachykinergic neurons with Substance P (SP). In Cav-1−/− mice: (i) ICC were Ano1-negative but maintained c-Kit expression, (ii) NK1 and NK2 receptor immunoreactivity was more intense and, in the SMC, mainly intracytoplasmatic, (iii) SP-immunoreactivity was significantly reduced. Under TEM: (i) ICC, SMC and telocytes lacked typical caveolae but had few and large flask-shaped vesicles we called large-sized caveolae; (ii) SMC and ICC contained an extraordinary high number of mitochondria, (iii) neurons were unchanged. To maintain intestinal motility, loss of caveolae and reduced calcium availability in Cav-1–knockout mice seem to be balanced by a highly increased number of mitochondria in ICC and SMC. Loss of Ano-1 expression, decrease of SP content and consequently overexpression of NK receptors suggest that all these molecules are Cav-1–associated proteins. PMID:21535398
Cipriani, G; Serboiu, Crenguta S; Gherghiceanu, Mihaela; Faussone-Pellegrini, Maria Simonetta; Vannucchi, Maria Giuliana
2011-11-01
Caveolin (Cav)-1 is an integral membrane protein of caveolae playing a crucial role in various signal transduction pathways. Caveolae represent the sites for calcium entry and storage especially in smooth muscle cells (SMC) and interstitial cells of Cajal (ICC). Cav-1(-/-) mice lack caveolae and show abnormalities in pacing and contractile activity of the small intestine. Presently, we investigated, by transmission electron microscopy (TEM) and immunohistochemistry, whether the absence of Cav-1 in Cav-1(-/-) mouse small intestine affects ICC, SMC and neuronal morphology, the expression of NK1 and NK2 receptors, and of Ano1 (also called Dog1 or TMEM16A), an essential molecule for slow wave activity in gastrointestinal muscles. ICC were also labelled with c-Kit and tachykinergic neurons with Substance P (SP). In Cav-1(-/-) mice: (i) ICC were Ano1-negative but maintained c-Kit expression, (ii) NK1 and NK2 receptor immunoreactivity was more intense and, in the SMC, mainly intracytoplasmatic, (iii) SP-immunoreactivity was significantly reduced. Under TEM: (i) ICC, SMC and telocytes lacked typical caveolae but had few and large flask-shaped vesicles we called large-sized caveolae; (ii) SMC and ICC contained an extraordinary high number of mitochondria, (iii) neurons were unchanged. To maintain intestinal motility, loss of caveolae and reduced calcium availability in Cav-1-knockout mice seem to be balanced by a highly increased number of mitochondria in ICC and SMC. Loss of Ano-1 expression, decrease of SP content and consequently overexpression of NK receptors suggest that all these molecules are Cav-1-associated proteins. © 2011 The Authors Journal of Cellular and Molecular Medicine © 2011 Foundation for Cellular and Molecular Medicine/Blackwell Publishing Ltd.
The Auckland Optotypes: An open-access pictogram set for measuring recognition acuity.
Hamm, Lisa M; Yeoman, Janice P; Anstice, Nicola; Dakin, Steven C
2018-03-01
When measuring recognition acuity in a research setting, the most widely used symbols are the Early Treatment of Diabetic Retinopathy Study (ETDRS) set of 10 Sloan letters. However, the symbols are not appropriate for patients unfamiliar with letters, and acuity for individual letters is variable. Alternative pictogram sets are available, but are generally comprised of fewer items. We set out to develop an open-access set of 10 pictograms that would elicit more consistent estimates of acuity across items than the ETDRS letters from visually normal adults. We measured monocular acuity for individual uncrowded optotypes within a newly designed set (The Auckland Optotype [TAO]), the ETDRS set, and Landolt Cs. Eleven visually normal adults were assessed on regular and vanishing formats of each set. Inter-optotype reliability and ability to detect subtle differences between participants were assessed using intraclass correlations (ICC) and fractional rank precision (FRP). The TAO vanishing set showed the strongest performance (ICC = 0.97, FRP = 0.90), followed by the other vanishing sets (Sloan ICC = 0.88, FRP = 0.74; Landolt ICC = 0.86, FRP = 0.80). Within the regular format, TAO again outperformed the existing sets (TAO ICC = 0.77, FRP = 0.75; Sloan ICC = 0.65, FRP = 0.64; Landolt ICC = 0.48, FRP = 0.63). For adults with normal visual acuity, the new optotypes (in both regular and vanishing formats) are more equally legible and sensitive to subtle individual differences than their Sloan counterparts. As this set does not require observers to be able to name Roman letters, and is freely available to use and modify, it may have wide application for measurement of acuity.
Fontseré, Néstor; Mestres, Gaspar; Barrufet, Marta; Burrel, Marta; Vera, Manel; Arias, Marta; Masso, Elisabeth; Cases, Aleix; Maduell, Francisco; Campistol, Josep M
2013-01-01
The current clinical guidelines recommend indirect access blood flow (Qa) measurement as one of the most important components in vascular access maintenance programs. The best-know methods are doppler ultrasound (DU) and saline dilution method. This study evaluates the efficiency of Qa measurement with thermodilution method (TD) in comparison with the DU. Transversal study in 64 patients in hemodialysis (41 men); mean age 59.9 years with 54 AVFs and 10 PTFE. Qa reference value was obtained with DU in brachial artery (AVFs) or at the zone of arterial puncture (AVGs). Bland-Altman and interclass correlation coefficient (ICC) were used to study accuracy. Mean values obtained with DU-Qa were 1426 ± 753 mL/min AVFs and 1186 ± 789 mL/min AVGs. The mean Qa with TD was 1372 ± 770 AVFs (bias 54.6; ICC 0.923) and 1176 ± 758 AVGs (bias 10.2; ICC 0.992). In the subgroup of 28 patients with radiocephalic latero-terminal AVFs the DU-Qa was 1232 ± 767 mL/min. The Qa was in radial artery 942 (ICC 0.805); radial-ulnar artery 1103 (ICC 0.973); cephalic vein 788 (ICC 0.772) and TD 1026 (ICC 0.971). We detected 5 cases of significant stenosis. After endovascular treatment the Kt was 79 liters (61; p=0.043) and TD-Qa 895 mL/min (663; p=0.043). TD represents a good indirect method of Qa measurement. In the subgroup of patients with radiocephalic AVFs, Qa measurements in the radial and ulnar artery are more accurate. Therefore, in this situation the TD method obtained an excellent correlation in comparison to brachial artery.
Reliability of videotaped observational gait analysis in patients with orthopedic impairments
Brunnekreef, Jaap J; van Uden, Caro JT; van Moorsel, Steven; Kooloos, Jan GM
2005-01-01
Background In clinical practice, visual gait observation is often used to determine gait disorders and to evaluate treatment. Several reliability studies on observational gait analysis have been described in the literature and generally showed moderate reliability. However, patients with orthopedic disorders have received little attention. The objective of this study is to determine the reliability levels of visual observation of gait in patients with orthopedic disorders. Methods The gait of thirty patients referred to a physical therapist for gait treatment was videotaped. Ten raters, 4 experienced, 4 inexperienced and 2 experts, individually evaluated these videotaped gait patterns of the patients twice, by using a structured gait analysis form. Reliability levels were established by calculating the Intraclass Correlation Coefficient (ICC), using a two-way random design and based on absolute agreement. Results The inter-rater reliability among experienced raters (ICC = 0.42; 95%CI: 0.38–0.46) was comparable to that of the inexperienced raters (ICC = 0.40; 95%CI: 0.36–0.44). The expert raters reached a higher inter-rater reliability level (ICC = 0.54; 95%CI: 0.48–0.60). The average intra-rater reliability of the experienced raters was 0.63 (ICCs ranging from 0.57 to 0.70). The inexperienced raters reached an average intra-rater reliability of 0.57 (ICCs ranging from 0.52 to 0.62). The two expert raters attained ICC values of 0.70 and 0.74 respectively. Conclusion Structured visual gait observation by use of a gait analysis form as described in this study was found to be moderately reliable. Clinical experience appears to increase the reliability of visual gait analysis. PMID:15774012
Achaintre, David; Sacerdote, Carlotta; Vineis, Paolo; Key, Timothy J.; Onland Moret, N. Charlotte; Scalbert, Augustin; Rinaldi, Sabina; Ferrari, Pietro
2015-01-01
Objective Although metabolic profiles have been associated with chronic disease risk, lack of temporal stability of metabolite levels could limit their use in epidemiological investigations. The present study aims to evaluate the reliability over a two-year period of 158 metabolites and compare reliability over time in fasting and non-fasting serum samples. Methods Metabolites were measured with the AbsolueIDQp180 kit (Biocrates, Innsbruck, Austria) by mass spectrometry and included acylcarnitines, amino acids, biogenic amines, hexoses, phosphatidylcholines and sphingomyelins. Measurements were performed on repeat serum samples collected two years apart in 27 fasting men from Turin, Italy, and 39 non-fasting women from Utrecht, The Netherlands, all participating in the European Prospective Investigation into Cancer and Nutrition (EPIC) study. Reproducibility was assessed by estimating intraclass correlation coefficients (ICCs) in multivariable mixed models. Results In fasting samples, a median ICC of 0.70 was observed. ICC values were <0.50 for 48% of amino acids, 27% of acylcarnitines, 18% of lysophosphatidylcholines and 4% of phosphatidylcholines. In non-fasting samples, the median ICC was 0.54. ICC values were <0.50 for 71% of acylcarnitines, 48% of amino acids, 44% of biogenic amines, 36% of sphingomyelins, 34% of phosphatidylcholines and 33% of lysophosphatidylcholines. Overall, reproducibility was lower in non-fasting as compared to fasting samples, with a statistically significant difference for 19–36% of acylcarnitines, phosphatidylcholines and sphingomyelins. Conclusion A single measurement per individual may be sufficient for the study of 73% and 52% of the metabolites showing ICCs >0.50 in fasting and non-fasting samples, respectively. ICCs were higher in fasting samples that are preferable to non-fasting. PMID:26274920
Salvarani, Carlo; Girolomoni, Giampiero; Di Lernia, Vito; Gisondi, Paolo; Tripepi, Giovanni; Egan, Colin Gerard; Marchesoni, Antonio
2016-12-01
To evaluate the impact of training on the reliability among dermatologists and rheumatologists in the assessment of psoriatic arthritis (PsA) patients. Overall, 9 hospital-based rheumatologists and 8 hospital-based dermatologists met in Reggio Emilia, Italy on October 2015 to assess 17 PsA patients. After 1 month, physicians underwent a 3-h training session by 4 recognized experts and then assessed 19 different PsA patients according to a modified Latin square design. Measures included tender (TJC) and swollen joint count (SJC), dactylitis, enthesitis, Schober test, psoriasis body surface area (BSA), Psoriasis Area and Severity Index (PASI), Nail Psoriasis Severity Index (NAPSI), and static physician's global assessment of PsA disease activity (sPGA). Variance components analyses were performed to estimate the intraclass correlation coefficient (ICC). TJC and enthesitis-measured pre-training by dermatologists or rheumatologists revealed moderate-substantial agreement (ICC: 0.4-0.8). In contrast, SJC and Schober test showed fair (ICC: 0.2-0.4) and moderate agreement, respectively (ICC: 0.4-0.6), while poor agreement (ICC: 0-0.2) was represented by dactylitis. Moderate-substantial (ICC: 0.4-0.8) agreement was observed for most skin measures by dermatologists and rheumatologists, apart from BSA, where fair agreement (ICC: 0.2-0.4) was observed. Agreement levels were similar before and after training for arthritis measures. In contrast, levels of agreement after training for 3 of the 4 skin measures were increased for dermatologists and all 4 skin measures were increased for rheumatologists. Substantial to excellent agreement was observed for TJC, enthesitis, PASI, and sPGA. Rheumatologists benefited from training to a greater extent. Copyright © 2016 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Galavis, P; Friedman, K; Chandarana, H
Purpose: Radiomics involves the extraction of texture features from different imaging modalities with the purpose of developing models to predict patient treatment outcomes. The purpose of this study is to investigate texture feature reproducibility across [18F]FDG PET/CT and [18F]FDG PET/MR imaging in patients with primary malignancies. Methods: Twenty five prospective patients with solid tumors underwent clinical [18F]FDG PET/CT scan followed by [18F]FDG PET/MR scans. In all patients the lesions were identified using nuclear medicine reports. The images were co-registered and segmented using an in-house auto-segmentation method. Fifty features, based on the intensity histogram, second and high order matrices, were extractedmore » from the segmented regions from both image data sets. One-way random-effects ANOVA model of the intra-class correlation coefficient (ICC) was used to establish texture feature correlations between both data sets. Results: Fifty features were classified based on their ICC values, which were found in the range from 0.1 to 0.86, in three categories: high, intermediate, and low. Ten features extracted from second and high-order matrices showed large ICC ≥ 0.70. Seventeen features presented intermediate 0.5 ≤ ICC ≤ 0.65 and the remaining twenty three presented low ICC ≤ 0.45. Conclusion: Features with large ICC values could be reliable candidates for quantification as they lead to similar results from both imaging modalities. Features with small ICC indicates a lack of correlation. Therefore, the use of these features as a quantitative measure will lead to different assessments of the same lesion depending on the imaging modality from where they are extracted. This study shows the importance of the need for further investigation and standardization of features across multiple imaging modalities.« less
Brunner, Alexander; Gühring, Markus; Schmälzle, Traude; Weise, Kuno; Badke, Andreas
2009-01-01
Evaluation of the kyphosis angle in thoracic and lumbar burst fractures is often used to indicate surgical procedures. The kyphosis angle could be measured as vertebral, segmental and local kyphosis according to the method of Cobb. The vertebral, segmental and local kyphosis according to the method of Cobb were measured at 120 lateral X-rays and sagittal computed tomographies of 60 thoracic and 60 lumbar burst fractures by 3 independent observers on 2 separate occasions. Osteoporotic fractures were excluded. The intra- and interobserver reliability of these angles in X-ray and computed tomogram, using the intra class correlation coefficient (ICC) were evaluated. Highest reproducibility showed the segmental kyphosis followed by the vertebral kyphosis. For thoracic fractures segmental kyphosis shows in X-ray “excellent” inter- and intraobserver reliabilities (ICC 0.826, 0.802) and for lumbar fractures “good” to “excellent” inter- and intraobserver reliabilities (ICC = 0.790, 0.803). In computed tomography, the segmental kyphosis showed “excellent” inter- and intraobserver reliabilities (ICC = 0.824, 0.801) for thoracic and “excellent” inter- and intraobserver reliabilities (ICC = 0.874, 0.835) for the lumbar fractures. Regarding both diagnostic work ups (X-ray and computed tomography), significant differences were evaluated in interobserver reliabilities for vertebral kyphosis measured in lumbar fracture X-rays (p = 0.035) and interobserver reliabilities for local kyphosis, measured in thoracic fracture X-rays (p = 0.010). Regarding both fracture localizations (thoracic and lumbar fractures), significant differences could only be evaluated in interobserver reliabilities for the local kyphosis measured in computed tomographies (p = 0.045) and in intraobserver reliabilities for the vertebral kyphosis measured in X-rays (p = 0.024). “Good” to “excellent” inter- and intraobserver reliabilities for vertebral, segmental and local kyphosis in X-ray make these angles to a helpful tool, indicating surgical procedures. For the practical use in lateral X-ray, we emphasize the determination of the segmental kyphosis, because of the highest reproducibility of this angle. “Good” to “excellent” inter- and intraobserver reliabilities for these three angles could also be evaluated in computed tomographies. Therefore, also in computed tomography, the use of these three angles seems to be generally possible. For a direct correlation of the results in lateral X-ray and in computed tomography, further studies should be needed. PMID:19953277
ERIC Educational Resources Information Center
Graham, Edmund
2016-01-01
Since the creation of Pathways to Results (PTR) in 2009, Illinois Central College (ICC) has participated in all but one year, working to improve outcomes across a number of different pathways. ICC has been innovative in its use of PTR over the years, and the 2014/2015 PTR project was no different. The ICC team worked to identify parallels between…
Ishimoto, Utako; Kondo, Shunsuke; Ohba, Akihiro; Sasaki, Mitsuhito; Sakamoto, Yasunari; Morizane, Chigusa; Ueno, Hideki; Okusaka, Takuji
2018-01-01
Intrahepatic cholangiocarcinoma (ICC) is a rare type of liver cancer. No clinically useful prognostic factors have been reported for patients with advanced ICC. In the present study, we aimed to evaluate the clinical prognostic factors of patients with advanced ICC receiving gemcitabine plus cisplatin combination therapy (GC) as standard first-line chemotherapy. A retrospective analysis was performed of the data of patients with ICC treated at our institution from March 2011 to January 2016. We used the Cox regression model and estimated the hazard ratios of potential prognostic factors for survival. Of 216 patients with biliary tract cancer receiving GC as first-line chemotherapy, we extracted data for 77 patients who were diagnosed with ICC and received GC as first-line chemotherapy. The median overall survival was 13.8 months (95% CI, 8.9-18.6). In multivariate analysis, pretreatment serum lactate dehydrogenase (hazard ratio [HR]: 2.53, p = 0.005), C-reactive protein (HR: 3.06, p = 0.001), and carcinoembryonic antigen (HR: 2.39, p = 0.03) levels were significantly associated with overall survival. Readily available clinical laboratory values reliably predicted the prognosis of ICC patients receiving GC therapy. If validated in other studies, these results may provide a useful tool for individual patient-risk evaluation and the design and interpretation of future trials. © 2017 S. Karger AG, Basel.
Ren, Keyu; Yong, Chunming; Yuan, Hao; Cao, Bin; Zhao, Kun; Wang, Jin
2018-01-01
Ulcerative colitis is a chronic inflammatory disease of the colon where intestinal motility is disturbed. Interstitial cells of Cajal (ICC) are required to maintain normal intestinal motility. In the present study, we assessed the effect of tumor necrosis factor-alpha (TNF-α) on viability and apoptosis of ICC, as well as on the expression of stem cell factor (SCF), ghrelin, and substance P. ICC were derived from the small intestines of Swiss albino mice. Cell viability and apoptosis were measured using CCK-8 assay and flow cytometry, respectively. ELISA was used to measure the concentrations of IL-1β, IL-6, ghrelin, substance P, and endothelin-1. Quantitative RT-PCR was used to measure the expression of SCF. Western blotting was used to measure the expression of apoptosis-related proteins, interleukins, SCF, and NF-κB signaling pathway proteins. TNF-α induced inflammatory injury in ICC by decreasing cell viability and increasing apoptosis and levels of IL-1β and IL-6. TNF-α decreased the levels of SCF, ghrelin, and substance P, but had no effect on endothelin-1. TNF-α down-regulated expressions of SCF, ghrelin, and substance P by activating the NF-κB pathway in ICC. In conclusion, TNF-α down-regulated the expressions of SCF, ghrelin, and substance P via the activation of the NF-κB pathway in ICC.
Tonon, S A; Picconi, M A; Bos, P D; Zinovich, J B; Galuppo, J; Alonio, L V; Teyssie, A R
2001-05-01
Integration of human papilloma virus (HPV) 16 DNA is considered an important genetic change in cervical lesion progression towards ICC. The viral E2 gene is often disrupted by this process, releasing suppression of viral E6/E7 oncogenes, a key factor for oncogenic progression. To evaluate the physical status of HPV 16 E2 gene in cervical preneoplastic and neoplastic lesions and its relation with lesion severity. A sensitive PCR approach for the detection of an intact E2 HPV 16 gene in infected epithelial cells from the cervix with low grade squamous intraepithelial lesion (LGSIL), high grade squamous intraepithelial lesion (HGSIL) and invasive cervical carcinoma (ICC) diagnosis was applied. The correlation between gene disruption and lesion stage was examined. Sixty-two LGSIL, 39 HGSIL and 24 ICC samples were analyzed. Fifty-seven LGSIL [92%], 13 HGSIL [33%] and 4 ICC [17%] showed results compatible with an intact E2 gene, while 5 LGSIL [8%], 26 HGSIL [67%] and 20 ICC [83%] samples gave no signal. HPV 16 E2 gene disruption showed a positive correlation with cervical lesion progression, particularly from LGSIL to HGSIL. Although additional genetic events are very likely to be needed for HGSIL to ICC progression, the E2 gene disruption is a putative early marker to consider in the prognostic analysis of HPV 16 chronically infected women.
Austin, Paul F; Bauer, Stuart B; Bower, Wendy; Chase, Janet; Franco, Israel; Hoebeke, Piet; Rittig, Søren; Vande Walle, Johan; von Gontard, Alexander; Wright, Anne; Yang, Stephen S; Nevéus, Tryggve
2014-06-01
The impact of the original International Children's Continence Society terminology document on lower urinary tract function resulted in the global establishment of uniformity and clarity in the characterization of lower urinary tract function and dysfunction in children across multiple health care disciplines. The present document serves as a stand-alone terminology update reflecting refinement and current advancement of knowledge on pediatric lower urinary tract function. A variety of worldwide experts from multiple disciplines in the ICCS leadership who care for children with lower urinary tract dysfunction were assembled as part of the standardization committee. A critical review of the previous ICCS terminology document and the current literature was performed. In addition, contributions and feedback from the multidisciplinary ICCS membership were solicited. Following a review of the literature during the last 7 years the ICCS experts assembled a new terminology document reflecting the current understanding of bladder function and lower urinary tract dysfunction in children using resources from the literature review, expert opinion and ICCS member feedback. The present ICCS terminology document provides a current and consensus update to the evolving terminology and understanding of lower urinary tract function in children. For the complete document visit http://jurology.com/. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
GPU accelerated implementation of NCI calculations using promolecular density.
Rubez, Gaëtan; Etancelin, Jean-Matthieu; Vigouroux, Xavier; Krajecki, Michael; Boisson, Jean-Charles; Hénon, Eric
2017-05-30
The NCI approach is a modern tool to reveal chemical noncovalent interactions. It is particularly attractive to describe ligand-protein binding. A custom implementation for NCI using promolecular density is presented. It is designed to leverage the computational power of NVIDIA graphics processing unit (GPU) accelerators through the CUDA programming model. The code performances of three versions are examined on a test set of 144 systems. NCI calculations are particularly well suited to the GPU architecture, which reduces drastically the computational time. On a single compute node, the dual-GPU version leads to a 39-fold improvement for the biggest instance compared to the optimal OpenMP parallel run (C code, icc compiler) with 16 CPU cores. Energy consumption measurements carried out on both CPU and GPU NCI tests show that the GPU approach provides substantial energy savings. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Within-Family Variability in Representations of Past Relationships With Parents
Tucker, Corinna Jenkins; Fingerman, Karen; Savla, Jyoti
2009-01-01
Background We examined within-family variation in siblings’ memories of experiences with parents and their associations with current positive and negative affect. Methods Participants were 1,369 adults with at least 1 sibling, aged 26–74 years from 498 families in the MacArthur Study of Midlife in the United States (Mage = 47 years, 59% women, 94% White). Results There was considerable variability in recalled maternal and paternal treatment across the dimensions of affection (intraclass correlation coefficients [ICCs] 0.33 and 0.41, respectively), discipline (ICCs 0.39 and 0.43), and conflict (ICCs 0.24 and 0.26). In turn, recalled parental treatment, particularly affection, made unique contributions to current positive (ICC 0.12) and negative affect (ICC 0.08) over and above individual and familial level characteristics such as offspring demographic characteristics, extraversion and neuroticism, family structure, recalled early family environment, and parents' current status. Conclusions Results link adults' memories of experiences with their parents in childhood to their current well-being and highlight the importance of considering within-family models for family theory. PMID:19176488
Childress, M O; Fulkerson, C M; Lahrman, S A; Weng, H-Y
2016-08-01
The purpose of this study was to assess reliability of lymph node measurements between and within raters in dogs with nodal lymphomas. Three raters measured lymph nodes from 20 dogs twice prior to and once after administering chemotherapy. Sum tumour volume (TV) and sum longest diameter (LD) of all lymph nodes at each time point, and the percent change in measurements following chemotherapy, were calculated for each dog. Inter- and intra-rater reliability were assessed with the intraclass correlation coefficient (ICC). ICC for inter-rater sum TV and sum LD prior to chemotherapy were 0.86 and 0.80, respectively. ICC for inter-rater sum TV and sum LD after chemotherapy were 0.95 and 0.91, respectively. ICC for percent change in sum TV and sum LD were 0.96 and 0.94, respectively. ICC for intra-rater reliability ranged from 0.90 to 0.98 for each rater. Inter- and intra-rater reliability in measurements among the three raters was good to excellent. © 2014 John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Monsky, Wayne L., E-mail: wayne.monsky@ucdmc.ucdavis.edu; Garza, Armando S.; Kim, Isaac
Purpose: The primary purpose of this study was to demonstrate intraobserver/interobserver reproducibility for novel semiautomated measurements of hepatic volume used for Yttrium-90 dose calculations as well as whole-liver and necrotic-liver (hypodense/nonenhancing) tumor volume after radioembolization. The secondary aim was to provide initial comparisons of tumor volumetric measurements with linear measurements, as defined by Response Evaluation Criteria in Solid Tumors criteria, and survival outcomes. Methods: Between 2006 and 2009, 23 consecutive radioembolization procedures were performed for 14 cases of hepatocellular carcinoma and 9 cases of hepatic metastases. Baseline and follow-up computed tomography obtained 1 month after treatment were retrospectively analyzed. Threemore » observers measured liver, whole-tumor, and tumor-necrosis volumes twice using semiautomated software. Results: Good intraobserver/interobserver reproducibility was demonstrated (intraclass correlation [ICC] > 0.9) for tumor and liver volumes. Semiautomated measurements of liver volumes were statistically similar to those obtained with manual tracing (ICC = 0.868), but they required significantly less time to perform (p < 0.0001, ICC = 0.088). There was a positive association between change in linear tumor measurements and whole-tumor volume (p < 0.0001). However, linear measurements did not correlate with volume of necrosis (p > 0.05). Dose, change in tumor diameters, tumor volume, and necrotic volume did not correlate with survival (p > 0.05 in all instances). However, Kaplan-Meier curves suggest that a >10% increase in necrotic volume correlated with survival (p = 0.0472). Conclusion: Semiautomated volumetric analysis of liver, whole-tumor, and tumor-necrosis volume can be performed with good intraobserver/interobserver reproducibility. In this small retrospective study, measurements of tumor necrosis were suggested to correlate with survival.« less
Enhanced spatio-temporal alignment of plantar pressure image sequences using B-splines.
Oliveira, Francisco P M; Tavares, João Manuel R S
2013-03-01
This article presents an enhanced methodology to align plantar pressure image sequences simultaneously in time and space. The temporal alignment of the sequences is accomplished using B-splines in the time modeling, and the spatial alignment can be attained using several geometric transformation models. The methodology was tested on a dataset of 156 real plantar pressure image sequences (3 sequences for each foot of the 26 subjects) that was acquired using a common commercial plate during barefoot walking. In the alignment of image sequences that were synthetically deformed both in time and space, an outstanding accuracy was achieved with the cubic B-splines. This accuracy was significantly better (p < 0.001) than the one obtained using the best solution proposed in our previous work. When applied to align real image sequences with unknown transformation involved, the alignment based on cubic B-splines also achieved superior results than our previous methodology (p < 0.001). The consequences of the temporal alignment on the dynamic center of pressure (COP) displacement was also assessed by computing the intraclass correlation coefficients (ICC) before and after the temporal alignment of the three image sequence trials of each foot of the associated subject at six time instants. The results showed that, generally, the ICCs related to the medio-lateral COP displacement were greater when the sequences were temporally aligned than the ICCs of the original sequences. Based on the experimental findings, one can conclude that the cubic B-splines are a remarkable solution for the temporal alignment of plantar pressure image sequences. These findings also show that the temporal alignment can increase the consistency of the COP displacement on related acquired plantar pressure image sequences.
Reliability of a visual scoring system with fluorescent tracers to assess dermal pesticide exposure.
Aragon, Aurora; Blanco, Luis; Lopez, Lylliam; Liden, Carola; Nise, Gun; Wesseling, Catharina
2004-10-01
We modified Fenske's semi-quantitative 'visual scoring system' of fluorescent tracer deposited on the skin of pesticide applicators and evaluated its reproducibility in the Nicaraguan setting. The body surface of 33 farmers, divided into 31 segments, was videotaped in the field after spraying with a pesticide solution containing a fluorescent tracer. A portable UV lamp was used for illumination in a foldaway dark room. The videos of five farmers were randomly selected. The scoring was based on a matrix with extension of fluorescent patterns (scale 0-5) on the ordinate and intensity (scale 0-5) on the abscissa, with the product of these two ranks as the final score for each body segment (0-25). Five medical students rated and evaluated the quality of 155 video images having undergone 4 h of training. Cronbach alpha coefficients and two-way random effects intraclass correlation coefficients (ICC) with absolute agreement were computed to assess inter-rater reliability. Consistency was high (Cronbach alpha = 0.96), but the scores differed substantially between raters. The overall ICC was satisfactory [0.75; 95% confidence interval (CI) = 0.62-0.83], but it was lower for intensity (0.54; 95% CI = 0.40-0.66) and higher for extension (0.80; 95% CI = 0.71-0.86). ICCs were lowest for images with low scores and evaluated as low quality, and highest for images with high scores and high quality. Inter-rater reliability coefficients indicate repeatability of the scoring system. However, field conditions for recording fluorescence should be improved to achieve higher quality images, and training should emphasize a better mechanism for the reading of body areas with low contamination.
Validity and reliability of the Nintendo Wii Balance Board for assessment of standing balance.
Clark, Ross A; Bryant, Adam L; Pua, Yonghao; McCrory, Paul; Bennell, Kim; Hunt, Michael
2010-03-01
Impaired standing balance has a detrimental effect on a person's functional ability and increases their risk of falling. There is currently no validated system which can precisely quantify center of pressure (COP), an important component of standing balance, while being inexpensive, portable and widely available. The Wii Balance Board (WBB) fits these criteria, and we examined its validity in comparison with the 'gold standard'-a laboratory-grade force platform (FP). Thirty subjects without lower limb pathology performed a combination of single and double leg standing balance tests with eyes open or closed on two separate occasions. Data from the WBB were acquired using a laptop computer. The test-retest reliability for COP path length for each of the testing devices, including a comparison of the WBB and FP data, was examined using intraclass correlation coefficients (ICC), Bland-Altman plots (BAP) and minimum detectable change (MDC). Both devices exhibited good to excellent COP path length test-retest reliability within-device (ICC=0.66-0.94) and between-device (ICC=0.77-0.89) on all testing protocols. Examination of the BAP revealed no relationship between the difference and the mean in any test, however the MDC values for the WBB did exceed those of the FP in three of the four tests. These findings suggest that the WBB is a valid tool for assessing standing balance. Given that the WBB is portable, widely available and a fraction of the cost of a FP, it could provide the average clinician with a standing balance assessment tool suitable for the clinical setting. Copyright 2009 Elsevier B.V. All rights reserved.
Egsgaard, Line Lindhardt
2016-01-01
Background Chronic pain is more prevalent among women; however, the majority of standardized pain drawings are often collected using male-like androgynous body representations. Objective The purpose of this study was to assess whether gender-specific and high-resolution three-dimensional (3D) body charts facilitate the communication of pain for women. Methods Using mixed-methods and a cross-over design, female patients with chronic pain were asked to provide detailed drawings of their current pain on masculine and feminine two-dimensional (2D) body schemas (N=41, Part I) or on female 2D and 3D high-resolution body schemas (N=41, Part II) on a computer tablet. The consistency of the drawings between body charts were assessed by intraclass correlation coefficient (ICC) and Bland-Altman plots. Semistructured interviews and a preference questionnaire were then used to obtain qualitative and quantitative responses of the drawing experience. Results The consistency between body charts were high (Part I: ICC=0.980, Part II: ICC=0.994). The preference ratio for the masculine to feminine body schemas were 6:35 and 18:23 for the 2D to 3D female body charts. Patients reported that the 3D body chart enabled a more accurate expression of their pain due to the detailed contours of the musculature and bone structure, however, patients also reported the 3D body chart was too human and believed that skin-like appearance limited ‘deep pain’ expressions. Conclusions Providing gender-specific body charts may facilitate the communication of pain and the level of detail (2D vs 3D body charts) should be used according to patients’ needs. PMID:27440737
Salavati, M; Krijnen, W P; Rameckers, E A A; Looijestijn, P L; Maathuis, C G B; van der Schans, C P; Steenbergen, B
2015-01-01
The aims of this study were to adapt the Gross Motor Function Measure-88 (GMFM-88) for children with Cerebral Palsy (CP) and Cerebral Visual Impairment (CVI) and to determine the test-retest and interobserver reliability of the adapted version. Sixteen paediatric physical therapists familiar with CVI participated in the adaptation process. The Delphi method was used to gain consensus among a panel of experts. Seventy-seven children with CP and CVI (44 boys and 33 girls, aged between 50 and 144 months) participated in this study. To assess test-retest and interobserver reliability, the GMFM-88 was administered twice within three weeks (Mean=9 days, SD=6 days) by trained paediatric physical therapists, one of whom was familiar with the child and one who wasn't. Percentages of identical scores, Cronbach's alphas and intraclass correlation coefficients (ICC) were computed for each dimension level. All experts agreed on the proposed adaptations of the GMFM-88 for children with CP and CVI. Test-retest reliability ICCs for dimension scores were between 0.94 and 1.00, mean percentages of identical scores between 29 and 71, and interobserver reliability ICCs of the adapted GMFM-88 were 0.99-1.00 for dimension scores. Mean percentages of identical scores varied between 53 and 91. Test-retest and interobserver reliability of the GMFM-88-CVI for children with CP and CVI was excellent. Internal consistency of dimension scores lay between 0.97 and 1.00. The psychometric properties of the adapted GMFM-88 for children with CP and CVI are reliable and comparable to the original GMFM-88. Copyright © 2015 Elsevier Ltd. All rights reserved.
A system for 3D representation of burns and calculation of burnt skin area.
Prieto, María Felicidad; Acha, Begoña; Gómez-Cía, Tomás; Fondón, Irene; Serrano, Carmen
2011-11-01
In this paper a computer-based system for burnt surface area estimation (BAI), is presented. First, a 3D model of a patient, adapted to age, weight, gender and constitution is created. On this 3D model, physicians represent both burns as well as burn depth allowing the burnt surface area to be automatically calculated by the system. Each patient models as well as photographs and burn area estimation can be stored. Therefore, these data can be included in the patient's clinical records for further review. Validation of this system was performed. In a first experiment, artificial known sized paper patches were attached to different parts of the body in 37 volunteers. A panel of 5 experts diagnosed the extent of the patches using the Rule of Nines. Besides, our system estimated the area of the "artificial burn". In order to validate the null hypothesis, Student's t-test was applied to collected data. In addition, intraclass correlation coefficient (ICC) was calculated and a value of 0.9918 was obtained, demonstrating that the reliability of the program in calculating the area is of 99%. In a second experiment, the burnt skin areas of 80 patients were calculated using BAI system and the Rule of Nines. A comparison between these two measuring methods was performed via t-Student test and ICC. The hypothesis of null difference between both measures is only true for deep dermal burns and the ICC is significantly different, indicating that the area estimation calculated by applying classical techniques can result in a wrong diagnose of the burnt surface. Copyright © 2011 Elsevier Ltd and ISBI. All rights reserved.
Three-Dimensional Eyeball and Orbit Volume Modification After LeFort III Midface Distraction.
Smektala, Tomasz; Nysjö, Johan; Thor, Andreas; Homik, Aleksandra; Sporniak-Tutak, Katarzyna; Safranow, Krzysztof; Dowgierd, Krzysztof; Olszewski, Raphael
2015-07-01
The aim of our study was to evaluate orbital volume modification with LeFort III midface distraction in patients with craniosynostosis and its influence on eyeball volume and axial diameter modification. Orbital volume was assessed by the semiautomatic segmentation method based on deformable surface models and on 3-dimensional (3D) interaction with haptics. The eyeball volumes and diameters were automatically calculated after manual segmentation of computed tomographic scans with 3D slicer software. The mean, minimal, and maximal differences as well as the standard deviation and intraclass correlation coefficient (ICC) for intraobserver and interobserver measurements reliability were calculated. The Wilcoxon signed rank test was used to compare measured values before and after surgery. P < 0.05 was considered statistically significant. Intraobserver and interobserver ICC for haptic-aided semiautomatic orbital volume measurements were 0.98 and 0.99, respectively. The intraobserver and interobserver ICC values for manual segmentation of the eyeball volume were 0.87 and 0.86, respectively. The orbital volume increased significantly after surgery: 30.32% (mean, 5.96 mL) for the left orbit and 31.04% (mean, 6.31 mL) for the right orbit. The mean increase in eyeball volume was 12.3%. The mean increases in the eyeball axial dimensions were 7.3%, 9.3%, and 4.4% for the X-, Y-, and Z-axes, respectively. The Wilcoxon signed rank test showed that preoperative and postoperative eyeball volumes, as well as the diameters along the X- and Y-axes, were statistically significant. Midface distraction in patients with syndromic craniostenosis results in a significant increase (P < 0.05) in the orbit and eyeball volumes. The 2 methods (haptic-aided semiautomatic segmentation and manual 3D slicer segmentation) are reproducible techniques for orbit and eyeball volume measurements.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baumueller, Stephan, E-mail: Stephan.Baumueller@usz.ch; Nguyen, Thi Dan Linh, E-mail: ThiDanLinh.Nguyen@usz.ch; Goetti, Robert Paul, E-mail: RobertPaul.Goetti@usz.ch
2011-12-15
Purpose: To assess the accuracy of maximum diameter measurements of aortic aneurysms after endovascular aneurysm repair (EVAR) on axial computed tomographic (CT) images in comparison to maximum diameter measurements perpendicular to the intravascular centerline for follow-up by using three-dimensional (3D) volume measurements as the reference standard. Materials and Methods: Forty-nine consecutive patients (73 {+-} 7.5 years, range 51-88 years), who underwent EVAR of an infrarenal aortic aneurysm were retrospectively included. Two blinded readers twice independently measured the maximum aneurysm diameter on axial CT images performed at discharge, and at 1 and 2 years after intervention. The maximum diameter perpendicular tomore » the centerline was automatically measured. Volumes of the aortic aneurysms were calculated by dedicated semiautomated 3D segmentation software (3surgery, 3mensio, the Netherlands). Changes in diameter of 0.5 cm and in volume of 10% were considered clinically significant. Intra- and interobserver agreements were calculated by intraclass correlations (ICC) in a random effects analysis of variance. The two unidimensional measurement methods were correlated to the reference standard. Results: Intra- and interobserver agreements for maximum aneurysm diameter measurements were excellent (ICC = 0.98 and ICC = 0.96, respectively). There was an excellent correlation between maximum aneurysm diameters measured on axial CT images and 3D volume measurements (r = 0.93, P < 0.001) as well as between maximum diameter measurements perpendicular to the centerline and 3D volume measurements (r = 0.93, P < 0.001). Conclusion: Measurements of maximum aneurysm diameters on axial CT images are an accurate, reliable, and robust method for follow-up after EVAR and can be used in daily routine.« less
Hatz, F; Hardmeier, M; Bousleiman, H; Rüegg, S; Schindler, C; Fuhr, P
2015-02-01
To compare the reliability of a newly developed Matlab® toolbox for the fully automated, pre- and post-processing of resting state EEG (automated analysis, AA) with the reliability of analysis involving visually controlled pre- and post-processing (VA). 34 healthy volunteers (age: median 38.2 (20-49), 82% female) had three consecutive 256-channel resting-state EEG at one year intervals. Results of frequency analysis of AA and VA were compared with Pearson correlation coefficients, and reliability over time was assessed with intraclass correlation coefficients (ICC). Mean correlation coefficient between AA and VA was 0.94±0.07, mean ICC for AA 0.83±0.05 and for VA 0.84±0.07. AA and VA yield very similar results for spectral EEG analysis and are equally reliable. AA is less time-consuming, completely standardized, and independent of raters and their training. Automated processing of EEG facilitates workflow in quantitative EEG analysis. Copyright © 2014 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
1999-02-25
An ORU Transfer Device (OTD) on top of the International Cargo Carrier (ICC) is checked by Manfred Nordhoff, with Daimler-Chrysler Aerospace (DASA); Ben Greene, with Lockheed Martin; Robert Wilkes (behind arm number two), with Lockheed Martin; Lora Laurence and Charles Franca, with Johnson Space Center. The OTD is a U.S.-built crane that will be stowed on the International Space Station's Unity module for use during future ISS assembly missions. The nonpressurized ICC fits inside the payload bay of the orbiter. The ICC will also carry the SPACEHAB Oceaneering Space System Box (SHOSS), a logistics items carrier. SHOSS can hold a maximum of 400 pounds of equipment and will carry items to be used during STS-96 and future ISS assembly flights. The ICC will fly on mission STS-96, targeted for launch on May 20
Disorders of interstitial cells of Cajal in a neonate with segmental dilatation of the intestine.
Okada, Tadao; Sasaki, Fumiaki; Honda, Shohei; Cho, Kazutosi; Matsuno, Yoshihiro; Itoh, Tomoo; Kubota, Kanako C; Todo, Satoru
2010-06-01
Localized myopathy of the muscular layers may be an important factor contributing to segmental dilatation of the intestine (SDI). Only one report has described SDI of the jejunum in a neonate showing no abnormality of the interstitial cells of Cajal (ICC). The present report describes the very rare case of a neonatal girl with segmental dilatation of the distal duodenum and proximal jejunum with irregular arrangements of Auerbach's plexus and ICC and the successful surgical treatment of SDI. We review the literature on this type of relationship between abnormality of ICC and SDI and discuss the clinical features of this complication. Furthermore, the possible neuropathic cause of SDI complicated with disorders of ICC was explored in this report. Copyright 2010 Elsevier Inc. All rights reserved.
LOCAL ORTHOGONAL CUTTING METHOD FOR COMPUTING MEDIAL CURVES AND ITS BIOMEDICAL APPLICATIONS
Einstein, Daniel R.; Dyedov, Vladimir
2010-01-01
Medial curves have a wide range of applications in geometric modeling and analysis (such as shape matching) and biomedical engineering (such as morphometry and computer assisted surgery). The computation of medial curves poses significant challenges, both in terms of theoretical analysis and practical efficiency and reliability. In this paper, we propose a definition and analysis of medial curves and also describe an efficient and robust method called local orthogonal cutting (LOC) for computing medial curves. Our approach is based on three key concepts: a local orthogonal decomposition of objects into substructures, a differential geometry concept called the interior center of curvature (ICC), and integrated stability and consistency tests. These concepts lend themselves to robust numerical techniques and result in an algorithm that is efficient and noise resistant. We illustrate the effectiveness and robustness of our approach with some highly complex, large-scale, noisy biomedical geometries derived from medical images, including lung airways and blood vessels. We also present comparisons of our method with some existing methods. PMID:20628546
Sehlen, Susanne; Ott, Martin; Marten-Mittag, Birgitt; Haimerl, Wolfgang; Dinkel, Andreas; Duehmke, Eckhart; Klein, Christian; Schaefer, Christof; Herschbach, Peter
2012-07-01
This study investigated feasibility and acceptance of computer-based assessment for the identification of psychosocial distress in routine radiotherapy care. 155 cancer patients were assessed using QSC-R10, PO-Bado-SF and Mach-9. The congruence between computerized tablet PC and conventional paper assessment was analysed in 50 patients. The agreement between the 2 modes was high (ICC 0.869-0.980). Acceptance of computer-based assessment was very high (>95%). Sex, age, education, distress and Karnofsky performance status (KPS) did not influence acceptance. Computerized assessment was rated more difficult by older patients (p = 0.039) and patients with low KPS (p = 0.020). 75.5% of the respondents supported referral for psycho-social intervention for distressed patients. The prevalence of distress was 27.1% (QSC-R10). Computer-based assessment allows easy identification of distressed patients. Level of staff involvement is low, and the results are quickly available for care providers. © Georg Thieme Verlag KG Stuttgart · New York.
RELIABILITY OF ANKLE-FOOT MORPHOLOGY, MOBILITY, STRENGTH, AND MOTOR PERFORMANCE MEASURES.
Fraser, John J; Koldenhoven, Rachel M; Saliba, Susan A; Hertel, Jay
2017-12-01
Assessment of foot posture, morphology, intersegmental mobility, strength and motor control of the ankle-foot complex are commonly used clinically, but measurement properties of many assessments are unclear. To determine test-retest and inter-rater reliability, standard error of measurement, and minimal detectable change of morphology, joint excursion and play, strength, and motor control of the ankle-foot complex. Reliability study. 24 healthy, recreationally-active young adults without history of ankle-foot injury were assessed by two clinicians on two occasions, three to ten days apart. Measurement properties were assessed for foot morphology (foot posture index, total and truncated length, width, arch height), joint excursion (weight-bearing dorsiflexion, rearfoot and hallux goniometry, forefoot inclinometry, 1 st metatarsal displacement) and joint play, strength (handheld dynamometry), and motor control rating during intrinsic foot muscle (IFM) exercises. Clinician order was randomized using a Latin Square. The clinicians performed independent examinations and did not confer on the findings for the duration of the study. Test-retest and inter-tester reliability and agreement was assessed using intraclass correlation coefficients (ICC 2,k ) and weighted kappa ( K w ). Test-retest reliability ICC were as follows: morphology: .80-1.00, joint excursion: .58-.97, joint play: -.67-.84, strength: .67-.92, IFM motor rating: K W -.01-.71. Inter-rater reliability ICC were as follows: morphology: .81-1.00, joint excursion: .32-.97, joint play: -1.06-1.00, strength: .53-.90, and IFM motor rating: K w .02-.56. Measures of ankle-foot posture, morphology, joint excursion, and strength demonstrated fair to excellent test-retest and inter-rater reliability. Test-retest reliability for rating of perceived difficulty and motor performance was good to excellent for short-foot, toe-spread-out, and hallux exercises and poor to fair for lesser toe extension. Joint play measures had poor to fair reliability overall. The findings of this study should be considered when choosing methods of clinical assessment and outcome measures in practice and research. 3.
CPM Test-Retest Reliability: "Standard" vs "Single Test-Stimulus" Protocols.
Granovsky, Yelena; Miller-Barmak, Adi; Goldstein, Oren; Sprecher, Elliot; Yarnitsky, David
2016-03-01
Assessment of pain inhibitory mechanisms using conditioned pain modulation (CPM) is relevant clinically in prediction of pain and analgesic efficacy. Our objective is to provide necessary estimates of intersession CPM reliability, to enable transformation of the CPM paradigm into a clinical tool. Two cohorts of young healthy subjects (N = 65) participated in two dual-session studies. In Study I, a Bath-Thermode CPM protocol was used, with hot water immersion and contact heat as conditioning- and test-stimuli, respectively, in a classical parallel CPM design introducing test-stimulus first, and then the conditioning- and repeated test-stimuli in parallel. Study II consisted of two CPM protocols: 1) Two-Thermodes, one for each of the stimuli, in the same parallel design as above, and 2) single test-stimulus (STS) protocol with a single administration of a contact heat test-stimulus, partially overlapped in time by a remote shorter contact heat as conditioning stimulus. Test-retest reliability was assessed within 3-7 days. The STS-CPM had superior reliability intraclass correlation (ICC 2 ,: 1 = 0.59) over Bath-Thermode (ICC 2 ,: 1 = 0.34) or Two-Thermodes (ICC 2 ,: 1 = 0.21) protocols. The hand immersion conditioning pain had higher reliability than thermode pain (ICC 2 ,: 1 = 0.76 vs ICC 2 ,: 1 = 0.16). Conditioned test-stimulus pain scores were of good (ICC 2 ,: 1 = 0.62) or fair (ICC 2 ,: 1 = 0.43) reliability for the Bath-Thermode and the STS, respectively, but not for the Two-Thermodes protocol (ICC 2 ,: 1 = 0.20). The newly developed STS-CPM paradigm was more reliable than other CPM protocols tested here, and should be further investigated for its clinical relevance. It appears that large contact size of the conditioning-stimulus and use of single rather than dual test-stimulus pain contribute to augmentation of CPM reliability. © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Sánchez-Lander, Jorge; Cortiñas, Paula; Loureiro, Carmen Luisa; Pujol, Flor Helene; Medina, Francisco; Capote-Negrín, Luis; Bianchi, Gino; García-Barriola, Victoria; Ruiz-Benni, Angela; Avilán-Rovira, José; Acosta, Humberto
2012-10-01
This study investigated the distribution of human papillomavirus (HPV) types in invasive cervical cancer (ICC), cervical intraepithelial neoplasia 2 (CIN2) and cervical intraepithelial neoplasia 3 (CIN3) in Venezuela. Paraffin-embedded samples from 329 women from 29 medical centers of the 24 states of Venezuela were analyzed to determine the distribution of HPV types for ICC, CIN2, and CIN3, the prevalence of single and multiple infection, and the association of HPV types with severity of lesion, comparing CIN2 versus CIN3+ (CIN3 and ICC). The samples were analyzed with the polymerase chain reaction (PCR) followed by reverse hybridization for the identification of HPV types. HPV was identified in 95/96 ICC specimens (98.9%), in 142/149 CIN3 (95.3%) and in 78/84 CIN2 samples (92.8%). The most common types for ICC and CIN3 were: HPV16, 18, 31, and 33, and for CIN2 were HPV16, 31, 51, 52, and 18. HPV single infection was found in 82.1% of ICC cases, in 79.4% of CIN2 cases, and in 77.4% of CIN3 cases. HPV16 was identified as a single infection more frequently in women with CIN3+ than in those with CIN2 (68.6% versus 46.7%, P=0.002), and HPV16 or HPV18 types were more prevalent in CIN3+ than in CIN2 (73.4% versus 50%, P=0.0006). this is the first study of the distribution of HPV types in ICC, CIN2, and CIN3 conducted throughout the territory of Venezuela. HPV16 and HPV18 were the most frequent HPV types identified in single and multiple infections in both ICC and CIN3 groups, and are associated with severity of lesion. The knowledge of the distribution of HPV types would allow organization of an HPV-DNA-based screening test, and consideration of the implementation of prophylactic vaccination in Venezuela. Copyright © 2012 Elsevier Ltd. All rights reserved.
Storey, K E; McCargar, L J
2012-02-01
Web-based surveys are becoming increasing popular. The present study aimed to assess the reliability and validity of the Web-Survey of Physical Activity and Nutrition (Web-SPAN) for self-report of height and weight, diet and physical activity by youth. School children aged 11-15years (grades 7-9; n=459) participated in the school-based research (boys, n=225; girls, n=233; mean age, 12.8years). Students completed Web-SPAN (self-administered) twice and participated in on-site school assessments [height, weight, 3-day food/pedometer record, Physical Activity Questionnaire for Older Children (PAQ-C), shuttle run]. Intraclass (ICC) and Pearson's correlation coefficients and paired samples t-tests were used to assess the test-retest reliability of Web-SPAN and to compare Web-SPAN with the on-site assessments. Test-retest reliability for height (ICC=0.90), weight (ICC=0.98) and the PAQ-C (ICC=0.79) were highly correlated, whereas correlations for nutrients were not as strong (ICC=0.37-0.64). There were no differences between Web-SPAN times 1 and 2 for height and weight, although there were differences for the PAQ-C and most nutrients. Web-SPAN was strongly correlated with the on-site assessments, including height (ICC=0.88), weight (ICC=0.93) and the PAQ-C (ICC=0.70). Mean differences for height and the PAQ-C were not significant, whereas mean differences for weight were significant resulting in an underestimation of being overweight/obesity prevalence (84% agreement). Correlations for nutrients were in the range 0.24-0.40; mean differences were small but generally significantly different. Correlations were weak between the web-based PAQ-C and 3-day pedometer record (r=0.28) and 20-m shuttle run (r=0.28). Web-SPAN is a time- and cost-effective method that can be used to assess the diet and physical activity status of youth in large cross-sectional studies and to assess group trends (weight status). © 2011 The Authors. Journal of Human Nutrition and Dietetics © 2011 The British Dietetic Association Ltd.
Lee, Teng-Yu; Hsu, Yao-Chun; Yu, Shi-Hang; Lin, Jaw-Town; Wu, Ming-Shiang; Wu, Chun-Ying
2018-06-01
Chronic infection with hepatitis B virus (HBV) increases risk of intrahepatic cholangiocarcinoma (ICC), but it is not clear whether antiviral therapy reduces risk. We investigated the association between nucleos(t)ide analogue therapy and ICC risk. We performed a nationwide long-term cohort study using Taiwan's National Health Insurance Research Database to obtain data on 185,843 patients with chronic HBV infection from October 1, 2003 through December 31, 2012. We excluded patients with confounding disorders such as infection with hepatitis C virus, HIV, or other hepatitis-associated viruses; liver flukes; biliary stone diseases; cholangitis; congenital biliary anomalies; biliary tract surgeries; or cancer. We identified 10,062 patients who received nucleos(t)ide analogue therapy (the treated group), and used propensity scores to match them (1:1) with patients who received hepatoprotectants (the untreated group). Cumulative incidences of and hazard ratios (HRs) for ICC development were analyzed. The cumulative incidence of ICC was significantly lower in the treated group after 3 years of therapy (1.28%; 95% CI, 0.56-2.01) than in the untreated group (3.14%; 95% CI, 2.02-4.27) and after 5 years of therapy (1.53%; 95% CI, 0.73-2.33 vs 4.32% in untreated group; 95% CI, 2.96-5.6869). In multivariable regression analysis, nucleos(t)ide analogue therapy was independently associated with a reduced risk of ICC (HR, 0.44; 95% CI, 0.25-0.78; P = .005). Older age (HR 1.05 per year; 95% CI, 1.03-1.07) and cirrhosis (HR, 2.80; 95% CI, 1.52-5.1415) were independently associated with an increased risk of ICC. Sensitivity analyses verified the association between nucleos(t)ide analogue therapy and a reduced ICC risk. A nationwide long-term cohort study in Taiwan showed that nucleos(t)ide analogue therapy for chronic HBV infection is significantly associated with a reduced ICC risk. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.
Clark, Ross A; Paterson, Kade; Ritchie, Callan; Blundell, Simon; Bryant, Adam L
2011-03-01
Commercial timing light systems (CTLS) provide precise measurement of athletes running velocity, however they are often expensive and difficult to transport. In this study an inexpensive, wireless and portable timing light system was created using the infrared camera in Nintendo Wii hand controllers (NWHC). System creation with gold-standard validation. A Windows-based software program using NWHC to replicate a dual-beam timing gate was created. Firstly, data collected during 2m walking and running trials were validated against a 3D kinematic system. Secondly, data recorded during 5m running trials at various intensities from standing or flying starts were compared to a single beam CTLS and the independent and average scores of three handheld stopwatch (HS) operators. Intraclass correlation coefficient and Bland-Altman plots were used to assess validity. Absolute error quartiles and percentage of trials in absolute error threshold ranges were used to determine accuracy. The NWHC system was valid when compared against the 3D kinematic system (ICC=0.99, median absolute error (MAR)=2.95%). For the flying 5m trials the NWHC system possessed excellent validity and precision (ICC=0.97, MAR<3%) when compared with the CTLS. In contrast, the NWHC system and the HS values during standing start trials possessed only modest validity (ICC<0.75) and accuracy (MAR>8%). A NWHC timing light system is inexpensive, portable and valid for assessing running velocity. Errors in the 5m standing start trials may have been due to erroneous event detection by either the commercial or NWHC-based timing light systems. Copyright © 2010 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Baert, Isabel A C; Lluch, Enrique; Struyf, Thomas; Peeters, Greta; Van Oosterwijck, Sophie; Tuynman, Joanna; Rufai, Salim; Struyf, Filip
2018-06-01
The therapeutic value of proprioceptive-based exercises in knee osteoarthritis (KOA) management warrants investigation of proprioceptive testing methods easily accessible in clinical practice. To estimate inter- and intrarater reliability of the knee joint position sense (KJPS) test and knee force sense (KFS) test in subjects with and without KOA. Cross-sectional test-retest design. Two blinded raters performed independently repeated measures of the KJPS and KFS test, using an analogue inclinometer and handheld dynamometer, respectively, in eight KOA patients (12 symptomatic knees) and 26 healthy controls (52 asymptomatic knees). Intraclass correlation coefficients (ICCs; model 2,1), standard error of measurement (SEM) and minimal detectable change with 95% confidence bounds (MDC 95 ) were calculated. For KJPS, results showed good to excellent test-retest agreement (ICCs 0.70-0.95 in KOA patients; ICCs 0.65-0.85 in healthy controls). A 2° measurement error (SEM 1°) was reported when measuring KJPS in multiple test positions and calculating mean repositioning error. Testing KOA patients pre and post therapy a repositioning error larger than 4° (MDC 95 ) is needed to consider true change. Measuring KFS using handheld dynamometry showed poor to fair interrater and poor to excellent intrarater reliability in subjects with and without KOA. Measuring KJPS in multiple test positions using an analogue inclinometer and calculating mean repositioning error is reliable and can be used in clinical practice. We do not recommend the use of the KFS test to clinicians. Further research is required to establish diagnostic accuracy and validity of our KJPS test in larger knee pain populations. Copyright © 2017 Elsevier Ltd. All rights reserved.
Israel, Benjamin; Buysse, Daniel J; Krafty, Robert T; Begley, Amy; Miewald, Jean; Hall, Martica
2012-09-01
Quantify the short-term stability of multiple indices of sleep and nocturnal physiology in good sleeper controls and primary insomnia patients. Intra-class correlation coefficients (ICC) were used to quantify the short-term stability of study outcomes. Sleep laboratory. Fifty-four adults with primary insomnia (PI) and 22 good sleeper controls (GSC). Visually scored sleep outcomes included indices of sleep duration, continuity, and architecture. Quantitative EEG outcomes included power in the delta, theta, alpha, sigma, and beta bands during NREM sleep. Power spectral analysis was used to estimate high-frequency heart rate variability (HRV) and the ratio of low- to high-frequency HRV power during NREM and REM sleep. With the exception of percent stage 3+4 sleep; visually scored sleep outcomes did not exhibit short-term stability across study nights. Most QEEG outcomes demonstrated short-term stability in both groups. Although power in the beta band was stable in the PI group (ICC = 0.75), it tended to be less stable in GSCs (ICC = 0.55). Both measures of cardiac autonomic tone exhibited short-term stability in GSCs and PIs during NREM and REM sleep. Most QEEG bandwidths and HRV during sleep show high short-term stability in good sleepers and patients with insomnia alike. One night of data is, thus, sufficient to derive reliable estimates of these outcomes in studies focused on group differences or correlates of QEEG and/or HRV. In contrast, one night of data is unlikely to generate reliable estimates of PSG-assessed sleep duration, continuity or architecture, with the exception of slow wave sleep.
O'Connor, S; McCaffrey, N; Whyte, E; Moran, K
2016-07-01
To adapt the trunk stability test to facilitate further sub-classification of higher levels of core stability in athletes for use as a screening tool. To establish the inter-tester and intra-tester reliability of this adapted core stability test. Reliability study. Collegiate athletic therapy facilities. Fifteen physically active male subjects (19.46 ± 0.63) free from any orthopaedic or neurological disorders were recruited from a convenience sample of collegiate students. The intraclass correlation coefficients (ICC) and 95% Confidence Intervals (CI) were computed to establish inter-tester and intra-tester reliability. Excellent ICC values were observed in the adapted core stability test for inter-tester reliability (0.97) and good to excellent intra-tester reliability (0.73-0.90). While the 95% CI were narrow for inter-tester reliability, Tester A and C 95% CI's were widely distributed compared to Tester B. The adapted core stability test developed in this study is a quick and simple field based test to administer that can further subdivide athletes with high levels of core stability. The test demonstrated high inter-tester and intra-tester reliability. Copyright © 2015 Elsevier Ltd. All rights reserved.
1999-02-25
At Astrotech, Titusville, Fla., Harald Schnier and Manfred Nordhoff, with Daimler-Chrysler Aerospace (DASA), look over the International Cargo Carrier that will be used during future International Space Station (ISS) assembly missions. On top is Robert Wilkes, with Lockheed Martin. Behind the ladder in the background is Ben Greene, with Lockheed Martin. The nonpressurized ICC fits inside the payload bay of the orbiter. The ICC will carry the SPACEHAB Oceaneering Space System Box (SHOSS), a logistics items carrier. SHOSS can hold a maximum of 400 pounds of equipment and will carry items to be used during STS-96 and future ISS assembly flights. Also aboard the ICC will be the ORU Transfer Device (OTD), a U.S.-built crane that will be stowed on Unity for use during future ISS assembly missions. The ICC will fly on mission STS-96, targeted for launch on May 20
Fascione, Jeanna M; Crews, Ryan T; Wrobel, James S
2012-01-01
Identifying the variability of footprint measurement collection techniques and the reliability of footprint measurements would assist with appropriate clinical foot posture appraisal. We sought to identify relationships between these measures in a healthy population. On 30 healthy participants, midgait dynamic footprint measurements were collected using an ink mat, paper pedography, and electronic pedography. The footprints were then digitized, and the following footprint indices were calculated with photo digital planimetry software: footprint index, arch index, truncated arch index, Chippaux-Smirak Index, and Staheli Index. Differences between techniques were identified with repeated-measures analysis of variance with post hoc test of Scheffe. In addition, to assess practical similarities between the different methods, intraclass correlation coefficients (ICCs) were calculated. To assess intrarater reliability, footprint indices were calculated twice on 10 randomly selected ink mat footprint measurements, and the ICC was calculated. Dynamic footprint measurements collected with an ink mat significantly differed from those collected with paper pedography (ICC, 0.85-0.96) and electronic pedography (ICC, 0.29-0.79), regardless of the practical similarities noted with ICC values (P = .00). Intrarater reliability for dynamic ink mat footprint measurements was high for the footprint index, arch index, truncated arch index, Chippaux-Smirak Index, and Staheli Index (ICC, 0.74-0.99). Footprint measurements collected with various techniques demonstrate differences. Interchangeable use of exact values without adjustment is not advised. Intrarater reliability of a single method (ink mat) was found to be high.
Gupta, Rahul; Togashi, Junichi; Akamatsu, Nobuhisa; Sakamoto, Yoshihiro; Kokudo, Norihiro
2017-08-01
Intrahepatic cholangiocarcinoma (ICC) or combined hepatocellular cholangiocarcinoma (cHCC-CC) is considered to be contraindications for liver transplantation (LT); however, recent studies have shown that the outcomes of LT in small incidental ICC/cHCC-CC tumors are comparable to those in HCC. Studies reporting the survival outcome of patient(s) undergoing LT and found to have incidental or misdiagnosed ICC and/or cHCC-CC in liver explants were reviewed. Our institutional data were also included in the review analysis. In this review, 21 studies reporting 19865 cases of liver transplantation were included. The incidence of misdiagnosed/incidental ICC/cHCC-CC in liver explants was found to be 0.7% (136/19636). Hepatitis B and C virus infection was reported in 19 and 47% of the cases, respectively. The recurrence rate after LT was 42%. The most common site for recurrence was extrahepatic (73%). The disease free survival rate at 3 years was reported to range 33-86%. The 3-year overall survival rate was reported be 22-70%. The outcome of LT in patients with incidental/misdiagnosed ICC/cHCC-CC was found to be poorer than that of matched patients with HCC in five studies; however, the outcome becomes equivalent to those of HCC in cases of small (<2 cm), well-differentiated ICC/cHCC-CC tumors without vascular invasion.
Bim is an Independent Prognostic Marker in Intrahepatic Cholangiocarcinoma.
Zhang, Henan; Jenkins, Sarah M; Lee, Chuang-Ta; Harrington, Susan M; Liu, Zhuogang; Dong, Haidong; Zhang, Lizhi
2018-04-23
Intrahepatic cholangiocarcinoma (ICC) is the second most common primary liver malignant tumor and has a poor prognosis. The prognostic factors associated with outcome remain poorly defined. In this study, we investigated the role of an important cell apoptosis initiator, Bcl-2 interacting mediator of cell death (Bim), by evaluating its expression and association with other clinicopathologic features in ICCs. We analyzed 56 cases of ICC with clinical follow-up. The expression of Bim in ICC cells and other cellular components was evaluated by immunohistochemistry. Bim expression was considered upregulated if Bim was detected in 10% or more of tumor cells. Of the 56 ICC samples, 19 (34%) had high Bim expression level, 15 (27%) were completely negative, and 22 (39%) were classified as low Bim expression (<10% positivity). Patients who had tumors with high Bim level had significantly longer overall survival than those with low or no staining (median survival, 7.6 vs 2.6 years; hazard ratio, 0.40; P=.006). High Bim expression was also correlated with low Ki-67 index, and more importantly, none of the tumors with high Bim expression had lymph node metastases at the time of surgery. Our study demonstrates that Bim is an important and independent prognostic factor in ICC. Tumors with high Bim expression are associated with better prognosis through inhibiting tumor cell proliferation and metastatic ability. The development of new agents directly or indirectly targeting Bim may provide promising anticancer treatments. Copyright © 2018. Published by Elsevier Inc.
A comprehensive ray tracing study on the impact of solar reflections from glass curtain walls.
Wong, Justin S J
2016-01-01
To facilitate the investigation of the impact of solar reflection from the façades of skyscrapers to surrounding environment, a comprehensive ray tracing model has been developed using the International Commerce Centre (ICC) in Hong Kong as an example. Taking into account the actual physical dimensions of buildings and meteorological data, the model simulates and traces the paths of solar reflections from ICC to the surrounding buildings, assessing the impact in terms of hit locations, light intensity and the hit time on each day throughout the year. Our analyses show that various design and architectural features of ICC have amplified the intensity of reflected solar rays and increased the hit rates of surrounding buildings. These factors include the high reflectivity of glass panels, their upward tilting angles, the concave profile of the 'Dragon Tail' (glass panels near the base), the particular location and orientation of ICC, as well as the immense height of ICC with its large reflective surfaces. The simulation results allow us to accurately map the date and time when the ray projections occur on each of the target buildings, rendering important information such as the number of converging (overlapping) projections, and the actual light intensity hitting each of the buildings at any given time. Comparisons with other skyscrapers such as Taipei 101 in Taiwan and 2-IFC (International Finance Centre) Hong Kong are made. Remedial actions for ICC and preventive measures are also discussed.
Interstitial cells of Cajal in chagasic megaesophagus.
de Lima, Marcus Aurelho; Cabrine-Santos, Marlene; Tavares, Marcelo Garcia; Gerolin, Gustavo Pacheco; Lages-Silva, Eliane; Ramirez, Luis Eduardo
2008-08-01
Chagasic visceromegalies are the most important digestive manifestations of Chagas disease and are characterized by motor disorders and dilation of organs such as esophagus and colon. One of the theories raised to explain the physiopathogenesis of chagasic megas is the plexus theory. Recent studies have shown a reduction of interstitial cells of Cajal (ICCs) in the colon of chagasic patients. These cells are present throughout the gastrointestinal tract and are considered to be pacemaker cells, that is, they are responsible for coordinating peristalsis and for mediating nerve impulses. In view of the lack of studies on these cells in megaesophagus and the previous observation of a reduction of ICCs in chagasic megacolons, we compared the distribution of ICCs in the esophagus of chagasic and nonchagasic patients to contribute to a better understanding of the physiopathogenesis of this esophageal disease. Esophageal biopsy samples from 10 chagasic and 5 nonchagasic patients were used. Cells were identified with the anti-CD117 antibody. The number of ICCs was quantified in longitudinal and circular muscle layers and myenteric plexus. The results were analyzed statistically by comparison of means. An intense reduction in the number of ICCs was observed in muscle layers and in the myenteric plexus of patients with megaesophagus. We conclude that there is an intense reduction of ICCs in the esophagus of chagasic patients when compared to nonchagasic patients, a finding supporting the important role of these cells in gastrointestinal tract motility. A deficiency in these cells might be implied in the genesis of megaesophagus.
2001-07-25
KENNEDY SPACE CENTER, Fla. -- The payload canister is lifted up the Rotating Service Structure on Launch Pad 39A. At right is Space Shuttle Discovery. Inside the canister are the primary payloads on mission STS-105, the Multi-Purpose Logistics Module Leonardo and the Integrated Cargo Carrier. The ICC holds several smaller payloads, the Early Ammonia Servicer and two experiment containers. The Early Ammonia Servicer consists of two nitrogen tanks that provide compressed gaseous nitrogen to pressurize the ammonia tank and replenish it in the thermal control subsystems of the Space Station. The ICC and MPLM will be lifted into the payload changeout room and then moved into the Discovery’s payload bay. The STS-105 mission includes a crew changeover on the International Space Station. Expedition Three will be traveling on Discovery to replace Expedition Two, who will return to Earth on board Discovery. Launch of STS-105 is scheduled for Aug. 9
Test-retest reliability of an fMRI paradigm for studies of cardiovascular reactivity.
Sheu, Lei K; Jennings, J Richard; Gianaros, Peter J
2012-07-01
We examined the reliability of measures of fMRI, subjective, and cardiovascular reactions to standardized versions of a Stroop color-word task and a multisource interference task. A sample of 14 men and 12 women (30-49 years old) completed the tasks on two occasions, separated by a median of 88 days. The reliability of fMRI BOLD signal changes in brain areas engaged by the tasks was moderate, and aggregating fMRI BOLD signal changes across the tasks improved test-retest reliability metrics. These metrics included voxel-wise intraclass correlation coefficients (ICCs) and overlap ratio statistics. Task-aggregated ratings of subjective arousal, valence, and control, as well as cardiovascular reactions evoked by the tasks showed ICCs of 0.57 to 0.87 (ps < .001), indicating moderate-to-strong reliability. These findings support using these tasks as a battery for fMRI studies of cardiovascular reactivity. Copyright © 2012 Society for Psychophysiological Research.
Comparing audio and video data for rating communication.
Williams, Kristine; Herman, Ruth; Bontempo, Daniel
2013-09-01
Video recording has become increasingly popular in nursing research, adding rich nonverbal, contextual, and behavioral information. However, benefits of video over audio data have not been well established. We compared communication ratings of audio versus video data using the Emotional Tone Rating Scale. Twenty raters watched video clips of nursing care and rated staff communication on 12 descriptors that reflect dimensions of person-centered and controlling communication. Another group rated audio-only versions of the same clips. Interrater consistency was high within each group with Interclass Correlation Coefficient (ICC) (2,1) for audio .91, and video = .94. Interrater consistency for both groups combined was also high with ICC (2,1) for audio and video = .95. Communication ratings using audio and video data were highly correlated. The value of video being superior to audio-recorded data should be evaluated in designing studies evaluating nursing care.
STS-105 MPLM is moved into the PCR
NASA Technical Reports Server (NTRS)
2001-01-01
KENNEDY SPACE CENTER, Fla. -- The payload canister is lifted up the Rotating Service Structure on Launch Pad 39A. At right is Space Shuttle Discovery. Inside the canister are the primary payloads on mission STS-105, the Multi-Purpose Logistics Module Leonardo and the Integrated Cargo Carrier. The ICC holds several smaller payloads, the Early Ammonia Servicer and two experiment containers. The Early Ammonia Servicer consists of two nitrogen tanks that provide compressed gaseous nitrogen to pressurize the ammonia tank and replenish it in the thermal control subsystems of the Space Station. The ICC and MPLM will be lifted into the payload changeout room and then moved into the Discoverys payload bay. The STS-105 mission includes a crew changeover on the International Space Station. Expedition Three will be traveling on Discovery to replace Expedition Two, who will return to Earth on board Discovery. Launch of STS-105 is scheduled for Aug. 9.
Kasaven, C P; McIntyre, G T; Mossey, P A
2017-01-01
Our objective was to assess the accuracy of virtual and printed 3-dimensional models derived from cone-beam computed tomographic (CT) scans to measure the volume of alveolar clefts before bone grafting. Fifteen subjects with unilateral cleft lip and palate had i-CAT cone-beam CT scans recorded at 0.2mm voxel and sectioned transversely into slices 0.2mm thick using i-CAT Vision. Volumes of alveolar clefts were calculated using first a validated algorithm; secondly, commercially-available virtual 3-dimensional model software; and finally 3-dimensional printed models, which were scanned with microCT and analysed using 3-dimensional software. For inter-observer reliability, a two-way mixed model intraclass correlation coefficient (ICC) was used to evaluate the reproducibility of identification of the cranial and caudal limits of the clefts among three observers. We used a Friedman test to assess the significance of differences among the methods, and probabilities of less than 0.05 were accepted as significant. Inter-observer reliability was almost perfect (ICC=0.987). There were no significant differences among the three methods. Virtual and printed 3-dimensional models were as precise as the validated computer algorithm in the calculation of volumes of the alveolar cleft before bone grafting, but virtual 3-dimensional models were the most accurate with the smallest 95% CI and, subject to further investigation, could be a useful adjunct in clinical practice. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Christoff, Adriana Oliveira; Barreto, Heloisa Gomm Arruda; Boerngen-Lacerda, Roseli
2016-07-28
The Alcohol, Smoking, and Substance Involvement Screening Test (ASSIST) is a reliable and valid tool for the early detection of harmful and hazardous drug use in primary care settings when administered by interview in the general population. In university students, substance use is high, so a reliable and feasible screening instrument is needed. To compare the computer-based ASSIST (ASSISTc) with the interview format (ASSISTi). A convenience sample with counterbalanced design was used alternating between the ASSISTi and ASSISTc with 15-day interval. Although this is not a traditional test-retest reliability study, the same statistical analysis was used: intraclass correlations (ICC), kappa (κ), and Cronbach's alpha (α) to compare the two formats. A satisfaction questionnaire was applied immediately after the second session. Both formats were completed by the students (n = 809) over 15 days. The scores of involvement with all substances and with tobacco, alcohol, cannabis, and cocaine obtained with the two formats demonstrated excellent ICC (> .77). The level of agreement was considered substantial for tobacco (κ = .69) and cannabis (κ = .70) and moderate for alcohol (κ = .58). The consistency of the ASSISTc was considered satisfactory (α: .85 for tobacco, .73 for alcohol, and .87 for cannabis). The analysis of satisfaction and feasibility showed that the ASSISTi was easier to understand, but the two formats were considered similar when considering acceptability, ease of responding, and degree of intimidation. The two formats are acceptable, the scores are comparable, and they can be used interchangeably.
Singanamalli, Asha; Rusu, Mirabela; Sparks, Rachel E; Shih, Natalie N C; Ziober, Amy; Wang, Li-Ping; Tomaszewski, John; Rosen, Mark; Feldman, Michael; Madabhushi, Anant
2016-01-01
To identify computer extracted in vivo dynamic contrast enhanced (DCE) MRI markers associated with quantitative histomorphometric (QH) characteristics of microvessels and Gleason scores (GS) in prostate cancer. This study considered retrospective data from 23 biopsy confirmed prostate cancer patients who underwent 3 Tesla multiparametric MRI before radical prostatectomy (RP). Representative slices from RP specimens were stained with vascular marker CD31. Tumor extent was mapped from RP sections onto DCE MRI using nonlinear registration methods. Seventy-seven microvessel QH features and 18 DCE MRI kinetic features were extracted and evaluated for their ability to distinguish low from intermediate and high GS. The effect of temporal sampling on kinetic features was assessed and correlations between those robust to temporal resolution and microvessel features discriminative of GS were examined. A total of 12 microvessel architectural features were discriminative of low and intermediate/high grade tumors with area under the receiver operating characteristic curve (AUC) > 0.7. These features were most highly correlated with mean washout gradient (WG) (max rho = -0.62). Independent analysis revealed WG to be moderately robust to temporal resolution (intraclass correlation coefficient [ICC] = 0.63) and WG variance, which was poorly correlated with microvessel features, to be predictive of low grade tumors (AUC = 0.77). Enhancement ratio was the most robust (ICC = 0.96) and discriminative (AUC = 0.78) kinetic feature but was moderately correlated with microvessel features (max rho = -0.52). Computer extracted features of prostate DCE MRI appear to be correlated with microvessel architecture and may be discriminative of low versus intermediate and high GS. © 2015 Wiley Periodicals, Inc.
Systematic review found AMSTAR, but not R(evised)-AMSTAR, to have good measurement properties.
Pieper, Dawid; Buechter, Roland Brian; Li, Lun; Prediger, Barbara; Eikermann, Michaela
2015-05-01
To summarize all available evidence on measurement properties in terms of reliability, validity, and feasibility of the Assessment of Multiple Systematic Reviews (AMSTAR) tool, including R(evised)-AMSTAR. MEDLINE, EMBASE, Psycinfo, and CINAHL were searched for studies containing information on measurement properties of the tools in October 2013. We extracted data on study characteristics and measurement properties. These data were analyzed following measurement criteria. We included 13 studies, four of them were labeled as validation studies. Nine articles dealt with AMSTAR, two articles dealt with R-AMSTAR, and one article dealt with both instruments. In terms of interrater reliability, most items showed a substantial agreement (>0.6). The median intraclass correlation coefficient (ICC) for the overall score of AMSTAR was 0.83 (range 0.60-0.98), indicating a high agreement. In terms of validity, ICCs were very high with all but one ICC lower than 0.8 when the AMSTAR score was compared with scores from other tools. Scoring AMSTAR takes between 10 and 20 minutes. AMSTAR seems to be reliable and valid. Further investigations for systematic reviews of other study designs than randomized controlled trials are needed. R-AMSTAR should be further investigated as evidence for its use is limited and its measurement properties have not been studied sufficiently. In general, test-retest reliability should be investigated in future studies. Copyright © 2015 Elsevier Inc. All rights reserved.
Liu, Tao; Zhu, Guanghu; Lin, Hualiang; Zhang, Yonghui; He, Jianfeng; Deng, Aiping; Peng, Zhiqiang; Xiao, Jianpeng; Rutherford, Shannon; Xie, Runsheng; Zeng, Weilin; Li, Xing; Ma, Wenjun
2017-01-01
Background Dengue fever (DF) in Guangzhou, Guangdong province in China is an important public health issue. The problem was highlighted in 2014 by a large, unprecedented outbreak. In order to respond in a more timely manner and hence better control such potential outbreaks in the future, this study develops an early warning model that integrates internet-based query data into traditional surveillance data. Methodology and principal findings A Dengue Baidu Search Index (DBSI) was collected from the Baidu website for developing a predictive model of dengue fever in combination with meteorological and demographic factors. Generalized additive models (GAM) with or without DBSI were established. The generalized cross validation (GCV) score and deviance explained indexes, intraclass correlation coefficient (ICC) and root mean squared error (RMSE), were respectively applied to measure the fitness and the prediction capability of the models. Our results show that the DBSI with one-week lag has a positive linear relationship with the local DF occurrence, and the model with DBSI (ICC:0.94 and RMSE:59.86) has a better prediction capability than the model without DBSI (ICC:0.72 and RMSE:203.29). Conclusions Our study suggests that a DSBI combined with traditional disease surveillance and meteorological data can improve the dengue early warning system in Guangzhou. PMID:28263988
NASA Technical Reports Server (NTRS)
Lin, Bing; Xu, Kuan-Man; Minnis, Patrick; Wielicki, Bruce A.; Hu, Yongxiang; Chambers, Lin; Fan, Alice; Sun, Wenbo
2007-01-01
Measurements of cloud properties and atmospheric radiation taken between January and August 1998 by the Tropical Rainfall Measuring Mission (TRMM) satellite were used to investigate the effect of spatial and temporal scales on the coincident occurrences of tropical individual cirrus clouds (ICCs) and deep convective systems (DCSs). It is found that there is little or even negative correlation between instantaneous occurrences of ICC and DCS in small areas, in which both types of clouds cannot grow and expand simultaneously. When spatial and temporal domains are increased, ICCs become more dependent on DCSs due to the origination of many ICCs from DCSs and moisture supply from the DCS in the upper troposphere for the ICCs to grow, resulting in significant positive correlation between the two types of tropical high clouds in large spatial and long temporal scales. This result may suggest that the decrease of tropical high clouds with SST from model simulations is likely caused by restricted spatial domains and limited temporal periods. Finally, the radiative feedback due to the change in tropical high cloud area coverage with sea surface temperature appears small and about -0.14 W/sq m per degree Kelvin.
Transdifferentiation of human periodontal ligament stem cells into pancreatic cell lineage.
Lee, Jeong Seok; An, Seong Yeong; Kwon, Il Keun; Heo, Jung Sun
2014-10-01
Human periodontal ligament-derived stem cells (PDLSCs) demonstrate self-renewal capacity and multilineage differentiation potential. In this study, we investigated the transdifferentiation potential of human PDLSCs into pancreatic islet cells. To form three-dimensional (3D) clusters, PDLSCs were cultured in Matrigel with media containing differentiation-inducing agents. We found that after 6 days in culture, PDLSCs underwent morphological changes resembling pancreatic islet-like cell clusters (ICCs). The morphological characteristics of PDLSC-derived ICCs were further assessed using scanning electron microscopy analysis. Using reverse transcription-polymerase chain reaction analysis, we found that pluripotency genes were downregulated, whereas early endoderm and pancreatic differentiation genes were upregulated, in PDLSC-derived ICCs compared with undifferentiated PDLSCs. Furthermore, we found that PDLSC-derived ICCs were capable of secreting insulin in response to high concentrations of glucose, validating their functional differentiation into islet cells. Finally, we also performed dithizone staining, as well as immunofluorescence assays and fluorescence-activated cell sorting analysis for pancreatic differentiation markers, to confirm the differentiation status of PDLSC-derived ICCs. These results demonstrate that PDLSCs can transdifferentiate into functional pancreatic islet-like cells and provide a novel, alternative cell population for pancreatic repair. Copyright © 2014 John Wiley & Sons, Ltd.
Bort-Roig, Judit; Puig-Ribera, Anna; Contreras, Ruth S; Chirveches-Pérez, Emilia; Martori, Joan C; Gilson, Nicholas D; McKenna, Jim
2017-09-15
This study validated the Walk@Work-Application (W@W-App) for measuring occupational sitting and stepping. The W@W-App was installed on the smartphones of office-based employees (n=17; 10 women; 26±3 years). A prescribed 1-hour laboratory protocol plus two continuous hours of occupational free-living activities were performed. Intra-class correlation coefficients (ICC) compared mean differences of sitting time and step count measurements between the W@W-App and criterion measures (ActivPAL3TM and SW200Yamax Digi-Walker). During the protocol, agreement between self-paced walking (ICC=0.85) and active working tasks step counts (ICC=0.80) was good. The smallest median difference was for sitting time (1.5seconds). During free-living conditions, sitting time (ICC=0.99) and stepping (ICC=0.92) showed excellent agreement, with a difference of 0.5minutes and 18 steps respectively. The W@W-App provided valid measures for monitoring occupational sedentary patterns in real life conditions; a key issue for increasing awareness and changing occupational sedentariness. Copyright © 2017 SESPAS. Publicado por Elsevier España, S.L.U. All rights reserved.
Segura-Correa, J C; Domínguez-Díaz, D; Avalos-Ramírez, R; Argaez-Sosa, J
2010-09-01
Knowledge of the intraherd correlation coefficient (ICC) and design (D) effect for infectious diseases could be of interest in sample size calculation and to provide the correct standard errors of prevalence estimates in cluster or two-stage samplings surveys. Information on 813 animals from 48 non-vaccinated cow-calf herds from North-eastern Mexico was used. The ICC for the bovine viral diarrhoea (BVD), infectious bovine rhinotracheitis (IBR), leptospirosis and neosporosis diseases were calculated using a Bayesian approach adjusting for the sensitivity and specificity of the diagnostic tests. The ICC and D values for BVD, IBR, leptospirosis and neosporosis were 0.31 and 5.91, 0.18 and 3.88, 0.22 and 4.53, and 0.11 and 2.68, respectively. The ICC and D values were different from 0 and D greater than 1, therefore large sample sizes are required to obtain the same precision in prevalence estimates than for a random simple sampling design. The report of ICC and D values is of great help in planning and designing two-stage sampling studies. 2010 Elsevier B.V. All rights reserved.
Vijayabharathi, Rajendran; Gopalakrishnan, Subramaniam; Sathya, Arumugam; Srinivas, Vadlamudi; Sharma, Mamta
2018-06-09
A total of 219 endophytic actinobacteria, isolated from roots, stems and leaves of chickpea, were characterized for antagonistic potential against Botrytis cinerea, causal organism of Botrytis grey mold (BGM) disease, in chickpea. Among them, three most potential endophytes, AUR2, AUR4 and ARR4 were further characterized for their plant growth-promoting (PGP) and nodulating potentials and host-plant resistance against B. cinerea, in chickpea. The sequences of 16 S rDNA gene of the three endophytes were matched with Streptomyces but different species. In planta, the isolate AUR4 alone was able to significantly enhance PGP traits including seed numbers (11.8 vs. 9.8/Plant), seed weight (8 vs. 6.8 g/Plant), pod numbers (13.6 vs. 11.5/Plant), pod weight (9.3 vs. 7.5 g/Plant) and biomass (10.9 vs. 8 g/Plant) over the un-inoculated control in chickpea genotype JG11. Interestingly, consortium of the selected endophytes, AUR2, AUR4 and ARR4 were found less effective than single inoculation. Co-inoculation of the selected endophytes with Mesorhizobium ciceri significantly enhanced nodulation and nitrogenase activity in five chickpea genotypes including ICCV2, ICCV10, ICC4958, Annigeri and JG11 over the un-inoculated control. The selected endophytes showed antagonistic potential in planta by significant reduction of disease incidence (28─52%) in both single inoculation and consortium treatments over the un-inoculated control across the genotypes ICC4954 (susceptible), ICCV05530 (moderately resistant) and JG11 (unknown resistance). Further, antioxidant enzymes such as superoxide dismutase, catalase, ascorbate peroxidase, guaiacol peroxidase, glutathione reductase, phenylalanine ammonia-lyase and polyphenol oxidase and phenolics were found induced in the leaves of chickpea inoculated with selected endophytes over un-inoculated control. Principal component analysis revealed that, the antioxidant enzymes and phenolics were found in the magnitude of ICC4954 < JG11 < ICCV05530 which correlates with their resistance level. The selected endophytes enhanced the plant growth and also host plant resistance against BGM in chickpea. Copyright © 2018 Elsevier Ltd. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-23
..., Reporter Brasil, the Citizens' Charcoal Institute (ICC), and the Pastoral Land Commission (CPT), indicate... Brasil, the Citizens' Charcoal Institute (ICC), and the Pastoral Land Commission (CPT), indicate that...
NASA Technical Reports Server (NTRS)
Liou, Luen-Woei; Ray, Asok
1991-01-01
A state feedback control law for integrated communication and control systems (ICCS) is formulated by using the dynamic programming and optimality principle on a finite-time horizon. The control law is derived on the basis of a stochastic model of the plant which is augmented in state space to allow for the effects of randomly varying delays in the feedback loop. A numerical procedure for synthesizing the control parameters is then presented, and the performance of the control law is evaluated by simulating the flight dynamics model of an advanced aircraft. Finally, recommendations for future work are made.
STS-105 ICC is moved to the payload canister for transport to pad 39A
NASA Technical Reports Server (NTRS)
2001-01-01
KENNEDY SPACE CENTER, Fla. -- The Integrated Cargo Carrier is lowered into the payload canister in front of the Multi-Purpose Logistics Module Leonardo. The ICC holds several payloads for mission STS-105, the Early Ammonia Servicer and two experiment containers. The canister will transport the MPLM and ICC transport to Launch Pad 39A where they will be placed in the payload bay of Space Shuttle Discovery. Launch of STS-105 is scheduled for 5:38 p.m. EDT Aug. 9
NASA Astrophysics Data System (ADS)
Pratesi, Fabio; Tapete, Deodato; Terenzi, Gloria; Del Ventisette, Chiara; Moretti, Sandro
2015-08-01
We propose a novel set of indexes to classify the information content of Persistent Scatterers (PS) and rate the health of engineering structures at urban to local scale. PS are automatically sampled and grouped via 'control areas' coinciding with the building and its surrounding environment. Density over the 'control areas' and velocity of PS are converted respectively into: Completeness of Information Index (Ici) that reflects the PS coverage grade; and Conservation Criticality Indexes (Icc) which rate the health condition of the monument separately for the object and surrounding control areas. The deformation pattern over the structure is classified as isolated (i) or diffused (d) based on the Velocity Distribution Index (Ivd). Both Ici and Icc are rated from A to E classes using a colour-coded system that intentionally emulates an energy-efficiency scale, to encourage the exploitation of PS by stakeholders and end-users in the practise of engineering surveying. Workability and reliability of the classification indexes are demonstrated over the urban heritage of Florence, Italy, using well established ERS-1/2 (1992-2000) descending, ENVISAT (2003-2010) ascending and descending PS datasets. The indexes are designed in perspective of handling outputs from InSAR processing of higher-resolution time series.
Wolf, Timothy J; Dahl, Abigail; Auen, Colleen; Doherty, Meghan
2017-07-01
The objective of this study was to evaluate the inter-rater reliability, test-retest reliability, concurrent validity, and discriminant validity of the Complex Task Performance Assessment (CTPA): an ecologically valid performance-based assessment of executive function. Community control participants (n = 20) and individuals with mild stroke (n = 14) participated in this study. All participants completed the CTPA and a battery of cognitive assessments at initial testing. The control participants completed the CTPA at two different times one week apart. The intra-class correlation coefficient (ICC) for inter-rater reliability for the total score on the CTPA was .991. The ICCs for all of the sub-scores of the CTPA were also high (.889-.977). The CTPA total score was significantly correlated to Condition 4 of the DKEFS Color-Word Interference Test (p = -.425), and the Wechsler Test of Adult Reading (p = -.493). Finally, there were significant differences between control subjects and individuals with mild stroke on the total score of the CTPA (p = .007) and all sub-scores except interpretation failures and total items incorrect. These results are also consistent with other current executive function performance-based assessments and indicate that the CTPA is a reliable and valid performance-based measure of executive function.
Kim, Jung Nam; Kim, Hyun Jung; Kim, Iksung; Kim, Yun Tai; Kim, Byung Joo
2018-01-01
Zingerone, a major component found in ginger root, is clinically effective for the treatment of various diseases. Interstitial cells of Cajal (ICCs) are the pacemaker cells responsible for slow waves in the gastrointestinal (GI) tract. We investigated the effects of zingerone on the pacemaker potentials of ICCs to assess its mechanisms of action and its potential as a treatment for GI tract motility disorder. We isolated ICCs from small intestines, and the whole-cell patch-clamp configuration was used to record the pacemaker potentials in cultured ICCs. Under the current clamping mode, zingerone inhibited pacemaker potentials of ICCs concentration-dependently. These effects were blocked not by capsazepine, a transient receptor potential vanilloid 1 (TRPV1) channel blocker, but by glibenclamide, a specific ATP-sensitive K+ channel blocker. Pretreatment with SQ-22536 (an adenylate cyclase inhibitor), LY294002 (a phosphoinositide 3-kinase inhibitor), and calphostin C (a protein kinase C (PKC) inhibitor) did not block the effects of zingerone on the pacemaker potentials relative to treatment with zingerone alone. However, zingerone-induced pacemaker potential inhibition was blocked by 1H-[1,2,4] oxadiazolo [4,3-a] quinoxalin-1-one (ODQ; a guanylate cyclase inhibitor), KT5823 (a protein kinase G (PKG) inhibitor), and L-NAME (a non-selective nitric oxide synthase (NOS) inhibitor). In addition, zingerone stimulated cyclic guanosine monophosphate (cGMP) production in ICCs. Finally, pretreatment with PD98059 (a p42/44 mitogen-activated protein kinase (MAPK) inhibitor), SB203580 (a p38 MAPK inhibitor), and SP600125 (c-Jun N-terminal kinases (JNK)-specific inhibitor) blocked the zingerone-induced pacemaker potential inhibition. These results suggest that zingerone concentration-dependently inhibits pacemaker potentials of ICCs via NO/cGMP-dependent ATP-sensitive K+ channels through MAPK-dependent pathways. Taken together, this study shows that zingerone may have the potential for development as a GI regulation agent. © 2018 The Author(s). Published by S. Karger AG, Basel.
The Reliability and Validity of the Computerized Double Inclinometer in Measuring Lumbar Mobility
MacDermid, Joy Christine; Arumugam, Vanitha; Vincent, Joshua Israel; Carroll, Krista L
2014-01-01
Study Design : Repeated measures reliability/validity study. Objectives : To determine the concurrent validity, test-retest, inter-rater and intra-rater reliability of lumbar flexion and extension measurements using the Tracker M.E. computerized dual inclinometer (CDI) in comparison to the modified-modified Schober (MMS) Summary of Background : Numerous studies have evaluated the reliability and validity of the various methods of measuring spinal motion, but the results are inconsistent. Differences in equipment and techniques make it difficult to correlate results. Methods : Twenty subjects with back pain and twenty without back pain were selected through convenience sampling. Two examiners measured sagittal plane lumbar range of motion for each subject. Two separate tests with the CDI and one test with the MMS were conducted. Each test consisted of three trials. Instrument and examiner order was randomly assigned. Intra-class correlations (ICCs 2, 2 and 2, 2) and Pearson correlation coefficients (r) were used to calculate reliability and concurrent validity respectively. Results : Intra-trial reliability was high to very high for both the CDI (ICCs 0.85 - 0.96) and MMS (ICCs 0.84 - 0.98). However, the reliability was poor to moderate, when the CDI unit had to be repositioned either by the same rate (ICCs 0.16 - 0.59) or a different rater (ICCs 0.45 - 0.52). Inter-rater reliability for the MMS was moderate to high (ICCs 0.75 - 0.82) which bettered the moderate correlation obtained for the CDI (ICCs 0.45 - 0.52). Correlations between the CDI and MMS were poor for flexion (0.32; p<0.05) and poor to moderate (-0.42 - -0.51; p<0.05) for extension measurements. Conclusion : When using the CDI, an average of subsequent tests is required to obtain moderate reliability. The MMS was highly reliable than the CDI. The MMS and the CDI measure lumbar movement on a different metric that are not highly related to each other. PMID:25352928
Intersession reliability of fMRI activation for heat pain and motor tasks
Quiton, Raimi L.; Keaser, Michael L.; Zhuo, Jiachen; Gullapalli, Rao P.; Greenspan, Joel D.
2014-01-01
As the practice of conducting longitudinal fMRI studies to assess mechanisms of pain-reducing interventions becomes more common, there is a great need to assess the test–retest reliability of the pain-related BOLD fMRI signal across repeated sessions. This study quantitatively evaluated the reliability of heat pain-related BOLD fMRI brain responses in healthy volunteers across 3 sessions conducted on separate days using two measures: (1) intraclass correlation coefficients (ICC) calculated based on signal amplitude and (2) spatial overlap. The ICC analysis of pain-related BOLD fMRI responses showed fair-to-moderate intersession reliability in brain areas regarded as part of the cortical pain network. Areas with the highest intersession reliability based on the ICC analysis included the anterior midcingulate cortex, anterior insula, and second somatosensory cortex. Areas with the lowest intersession reliability based on the ICC analysis also showed low spatial reliability; these regions included pregenual anterior cingulate cortex, primary somatosensory cortex, and posterior insula. Thus, this study found regional differences in pain-related BOLD fMRI response reliability, which may provide useful information to guide longitudinal pain studies. A simple motor task (finger-thumb opposition) was performed by the same subjects in the same sessions as the painful heat stimuli were delivered. Intersession reliability of fMRI activation in cortical motor areas was comparable to previously published findings for both spatial overlap and ICC measures, providing support for the validity of the analytical approach used to assess intersession reliability of pain-related fMRI activation. A secondary finding of this study is that the use of standard ICC alone as a measure of reliability may not be sufficient, as the underlying variance structure of an fMRI dataset can result in inappropriately high ICC values; a method to eliminate these false positive results was used in this study and is recommended for future studies of test–retest reliability. PMID:25161897
Fell, Matthew; Meirte, Jill; Anthonissen, Mieke; Maertens, Koen; Pleat, Jonathon; Moortgat, Peter
2016-03-01
Objective scar assessment tools were designed to help identify problematic scars and direct clinical management. Their use has been restricted by their measurement of a single scar property and the bulky size of equipment. The Scarbase Duo(®) was designed to assess both trans-epidermal water loss (TEWL) and colour of a burn scar whilst being compact and easy to use. Twenty patients with a burn scar were recruited and measurements taken using the Scarbase Duo(®) by two observers. The Scarbase Duo(®) measures TEWL via an open-chamber system and undertakes colorimetry via narrow-band spectrophotometry, producing values for relative erythema and melanin pigmentation. Validity was assessed by comparing the Scarbase Duo(®) against the Dermalab(®) and the Minolta Chromameter(®) respectively for TEWL and colorimetry measurements. The intra-class correlation coefficient (ICC) was used to assess reliability with standard error of measurement (SEM) used to assess reproducibility of measurements. The Pearson correlation coefficient (r) was used to assess the convergent validity. The Scarbase Duo(®) TEWL mode had excellent reliability when used on scars for both intra- (ICC=0.95) and inter-rater (ICC=0.96) measurements with moderate SEM values. The erythema component of the colorimetry mode showed good reliability for use on scars for both intra-(ICC=0.81) and inter-rater (ICC=0.83) measurements with low SEM values. Pigmentation values showed excellent reliability on scar tissue for both intra- (ICC=0.97) and inter-rater (ICC=0.97) with moderate SEM values. The Scarbase Duo(®) TEWL function had excellent correlation with the Dermalab(®) (r=0.93) whilst the colorimetry erythema value had moderate correlation with the Minolta Chromameter (r=0.72). The Scarbase Duo(®) is a reliable and objective scar assessment tool, which is specifically designed for burn scars. However, for clinical use, standardised measurement conditions are recommended. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.
Ruschel, Caroline; Haupenthal, Alessandro; Jacomel, Gabriel Fernandes; Fontana, Heiliane de Brito; Santos, Daniela Pacheco dos; Scoz, Robson Dias; Roesler, Helio
2015-05-20
Isometric muscle strength of knee extensors has been assessed for estimating performance, evaluating progress during physical training, and investigating the relationship between isometric and dynamic/functional performance. To assess the validity and reliability of an adapted leg-extension machine for measuring isometric knee extensor force. Validity (concurrent approach) and reliability (test and test-retest approach) study. University laboratory. 70 healthy men and women aged between 20 and 30 y (39 in the validity study and 31 in the reliability study). Intraclass correlation coefficient (ICC) values calculated for the maximum voluntary isometric torque of knee extensors at 30°, 60°, and 90°, measured with the prototype and with an isokinetic dynamometer (ICC2,1, validity study) and measured with the prototype in test and retest sessions, scheduled from 48 h to 72 h apart (ICC1,1, reliability study). In the validity analysis, the prototype showed good agreement for measurements at 30° (ICC2,1 = .75, SEM = 18.2 Nm) and excellent agreement for measurements at 60° (ICC2,1 = .93, SEM = 9.6 Nm) and at 90° (ICC2,1 = .94, SEM = 8.9 Nm). Regarding the reliability analysis, between-days' ICC1,1 were good to excellent, ranging from .88 to .93. Standard error of measurement and minimal detectable difference based on test-retest ranged from 11.7 Nm to 18.1 Nm and 32.5 Nm to 50.1 Nm, respectively, for the 3 analyzed knee angles. The analysis of validity and repeatability of the prototype for measuring isometric muscle strength has shown to be good or excellent, depending on the knee joint angle analyzed. The new instrument, which presents a relative low cost and easiness of transportation when compared with an isokinetic dynamometer, is valid and provides consistent data concerning isometric strength of knee extensors and, for this reason, can be used for practical, clinical, and research purposes.