Annular Momentum Control Device (AMCD). Volume 1: Laboratory model development
NASA Technical Reports Server (NTRS)
1975-01-01
The annular momentum control device (AMCD) a thin hoop-like wheel with neither shaft nor spokes is described. The wheel floats in a magnetic field and can be rotated by a segmented motor. Potential advantages of such a wheel are low weight, configuration flexibility, a wheel that stiffens with increased speed, vibration isolation, and increased reliability. The analysis, design, fabrication, and testing is described of the laboratory model of the AMCD.
A controller design approach for large flexible space structures
NASA Technical Reports Server (NTRS)
Joshi, S. M.
1981-01-01
A controller design approach for large space structures is presented, which consists of a primary attitude controller and a secondary or damping enhancement controller. The secondary controller, which uses several Annular Momentum Control Device (AMCD's), is shown to make the closed loop system asymptotically stable under relatively simple conditions. The primary controller using torque actuators (or AMCD's) and colocated attitude and rate sensors is shown to be stable. It is shown that the same AMCD's can be used for simultaneous actuation of primary and secondary controllers. Numerical results are obtained for a large, thin, completely free plate model.
Synchronous response modelling and control of an annular momentum control device
NASA Astrophysics Data System (ADS)
Hockney, Richard; Johnson, Bruce G.; Misovec, Kathleen
1988-08-01
Research on the synchronous response modelling and control of an advanced Annular Momentun Control Device (AMCD) used to control the attitude of a spacecraft is described. For the flexible rotor AMCD, two sources of synchronous vibrations were identified. One source, which corresponds to the mass unbalance problem of rigid rotors suspended in conventional bearings, is caused by measurement errors of the rotor center of mass position. The other sources of synchronous vibrations is misalignment between the hub and flywheel masses of the AMCD. Four different control algorithms were examined. These were lead-lag compensators that mimic conventional bearing dynamics, tracking notch filters used in the feedback loop, tracking differential-notch filters, and model-based compensators. The tracking differential-notch filters were shown to have a number of advantages over more conventional approaches for both rigid-body rotor applications and flexible rotor applications such as the AMCD. Hardware implementation schemes for the tracking differential-notch filter were investigated. A simple design was developed that can be implemented with analog multipliers and low bandwidth, digital hardware.
Synchronous response modelling and control of an annular momentum control device
NASA Technical Reports Server (NTRS)
Hockney, Richard; Johnson, Bruce G.; Misovec, Kathleen
1988-01-01
Research on the synchronous response modelling and control of an advanced Annular Momentun Control Device (AMCD) used to control the attitude of a spacecraft is described. For the flexible rotor AMCD, two sources of synchronous vibrations were identified. One source, which corresponds to the mass unbalance problem of rigid rotors suspended in conventional bearings, is caused by measurement errors of the rotor center of mass position. The other sources of synchronous vibrations is misalignment between the hub and flywheel masses of the AMCD. Four different control algorithms were examined. These were lead-lag compensators that mimic conventional bearing dynamics, tracking notch filters used in the feedback loop, tracking differential-notch filters, and model-based compensators. The tracking differential-notch filters were shown to have a number of advantages over more conventional approaches for both rigid-body rotor applications and flexible rotor applications such as the AMCD. Hardware implementation schemes for the tracking differential-notch filter were investigated. A simple design was developed that can be implemented with analog multipliers and low bandwidth, digital hardware.
NASA Technical Reports Server (NTRS)
Groom, N. J.
1979-01-01
The rim inertial measuring system (RIMS) is introduced and an approach for extracting angular rate and linear acceleration information from a RIMS unit is presented and discussed. The RIMS consists of one or more small annular momentum control devices (AMCDs), mounted in a strapped down configuration, which are used to measure angular rates and linear accelerations of a moving vehicle. An AMCD consists of a spinning rim, a set of noncontacting magnetic bearings for supporting the rim, and a noncontacting electromagnetic spin motor. The approach for extracting angular rate and linear acceleration information is for a single spacecraft mounted RIMS unit.
NASA Technical Reports Server (NTRS)
Groom, N. J.; Anderson, W. W.; Phillips, W. H. (Inventor)
1981-01-01
The invention includes an angular momentum control device (AMCD) having a rim and several magnetic bearing stations. The AMCD is in a strapped down position on a spacecraft. Each magnetic bearing station comprises means, including an axial position sensor, for controlling the position of the rim in the axial direction; and means, including a radial position sensor, for controlling the position of the rim in the radial direction. A first computer receives the signals from all the axial position sensors and computes the angular rates about first and second mutually perpendicular axes in the plane of the rim and computes the linear acceleration along a third axis perpendicular to the first and second axes. A second computer receives the signals from all the radial position sensors and computes the linear accelerations along the first and second axes.
A magnetic bearing control approach using flux feedback
NASA Technical Reports Server (NTRS)
Groom, Nelson J.
1989-01-01
A magnetic bearing control approach using flux feedback is described and test results for a laboratory model magnetic bearing actuator are presented. Test results were obtained using a magnetic bearing test fixture, which is also described. The magnetic bearing actuator consists of elements similar to those used in a laboratory test model Annular Momentum Control Device (AMCD).
Annual Anastasia Arbovirus Surveillance and Mosquito Control Workshops: Summary of the Past 11 Years
USDA-ARS?s Scientific Manuscript database
Realizing the needs of local mosquito control workers for advance training and education the Anastasia Mosquito Control District (AMCD) and the USDA-ARS Center for Medical, Agricultural and Veterinary entomology (CMAVE) developed a regional workshop to address these needs. Since 2004 the AMCD and CM...
NASA Technical Reports Server (NTRS)
Groom, N. J.; Woolley, C. T.; Joshi, S. M.
1981-01-01
A linear analysis and the results of a nonlinear simulation of a magnetic bearing suspension system which uses permanent magnet flux biasing are presented. The magnetic bearing suspension is part of a 4068 N-m-s (3000 lb-ft-sec) laboratory model annular momentum control device (AMCD). The simulation includes rigid body rim dynamics, linear and nonlinear axial actuators, linear radial actuators, axial and radial rim warp, and power supply and power driver current limits.
Overview of magnetic suspension research at Langley Research Center
NASA Technical Reports Server (NTRS)
Groom, Nelson J.
1992-01-01
An overview of research in small- and large-gap magnetic suspension systems at LaRC is presented. The overview is limited to systems which have been built as laboratory models or engineering models. Small-gap systems applications include the Annular Momentum Control Device (AMCD), which is a momentum storage device for the stabilization and control of spacecraft, and the Annular Suspension and Pointing System (ASPS), which is a general purpose pointing mount designed to provide orientation, mechanical isolation, and fine pointing space experiments. These devices are described and control and linearization approaches for the magnetic suspension systems for these devices are discussed. Large-gap systems applications at LaRC have been almost exclusively wind tunnel magnetic suspension systems. A brief description of these efforts is also presented.
A simple laser-based device for simultaneous microbial culture and absorbance measurement
NASA Astrophysics Data System (ADS)
Abrevaya, X. C.; Cortón, E.; Areso, O.; Mauas, P. J. D.
2013-07-01
In this work we present a device specifically designed to study microbial growth with several applications related to environmental microbiology and other areas of research as astrobiology. The Automated Measuring and Cultivation device (AMC-d) enables semi-continuous absorbance measurements directly during cultivation. It can measure simultaneously up to 16 samples. Growth curves using low and fast growing microorganism were plotted, including Escherichia coli and Haloferax volcanii, a halophilic archaeon.
Magnetic suspension system for an Annular Momentum Control Device (AMCD)
NASA Technical Reports Server (NTRS)
1979-01-01
A technique to control a rim suspended in a magnetic field was developed. A complete system was developed, incorporating a support structure, magnetic actuators, a rim drive mechanism, an emergency fail-safe system, servo control system, and control electronics. Open loop and closed loop response of the system at zero speed and at 500 revolutions per minute (r/min) of the rim was obtained and analyzed. The rim was then dynamically balanced and a rim speed of 725 r/min was achieved. An analog simulation of the hardware was developed and tested with the actual control electronics connected to the analog computer. The system under development is stable at rim speeds below 700 r/min. Test results indicate that the rim under test is not rigid. The rim has a warp and a number of binding modes which prevented achievement of higher speeds. Further development efforts are required to achieve higher rim speeds.
Suganuma, Y; Dhirani, A-A
2011-04-01
The present study explores a novel apertured microchip conductance detector (AMCD) that is sensitive to dielectric constant. Fashioned on silicon oxide/silicon using optical microlithography, the detector has novel parallel-plate geometry with a top mesh electrode, a middle apertured insulator, and a bottom conducting electrode. This monolithic apertured architecture is planar and may be provided with a thin insulator layer enabling large capacitances, while the top mesh electrode and middle apertured-insulator enable access to regions of the capacitor where electric fields are strong. Hence, the detector is sensitive yet mechanically robust. To test its response, the AMCD was immersed in various solvents, namely water, methanol, acetonitrile, and hexanes. Its response was found to vary in proportion to the solvents' respective dielectric constants. The AMCD was also able to distinguish quantitatively the presence of various molecules in solution, including molecules with chromophores [such as acetylsalicylic acid (ASA)] in methanol and those without chrompohores [such as polyethylene glycol 200 Daltons (PEG200)] in methanol or water. The universal nature of dielectric constant and the microchip detector's sensitivity point to a wide range of potential applications. © 2011 American Institute of Physics
Camelio, Kinsey; Gibson, Jennifer; Smith, Michael L; Drake, Lisa L; Xue, Rui-De
2016-06-01
The Anastasia Mosquito Control District (AMCD) tests all equipment before field use to determine if machines are suitable for the needs of the district. Three handheld ultra-low-volume (ULV) foggers--the American LongRay (ULV) Fogger Model 3600B with rechargeable lithium battery (DC model), American LongRay ULV Fogger Model 3600E with 110V or 220V AC power (AC model), and Boston Fog Battery Motorized Fogger (Boston Fogger)--were compared to determine which fogger would be most suitable for use by AMCD. Mortality of caged Aedes albopictus was analyzed after 24 h to determine the success of a single application. All 3 foggers resulted in 100% mortality after 24 h using the insecticide Aqualuer 20-20 (active ingredients permethrin 20.6% and piperonyl butoxide 20.6%) 1:5 dilution with reverse osmosis water. Based on operator safety, robustness, and operational performance, the American LongRay DC model was found to be the most suitable at administering Aqualuer 20-20 against caged adult Ae. albopictus.
Materiel Acquisition Handbook. Revision
1987-03-26
DISTRIBUTION: CINC USAREUR & SEVEN.TH ARMY (AEAGC- FMD (75)) (if primary user) (see over) S. A TRANSMITTAL LETTERS OFFICE SYMBOL SUBJECT: DISTRIBUTICN...outlines adv•;rtising procedures and the process for collecting and considering industry comments. ft-F .’.0. , ftA - ATCD-ET/AMCDE-PQ SUBJECT: Letter of
ERIC Educational Resources Information Center
Roysircar, Gargi; Arredondo, Patricia; Fuertes, Jairo N.; Ponterotto, Joseph G.; Toporek, Rebecca L.
This book updates earlier Association for Multicultural Counseling and Development (AMCD) multicultural counseling competencies (MCC). Each chapter author particularizes definitions and/or conceptualizations of multicultural competencies to the topic of his or her chapter. The present document operationalizes the MCC into practice examples,…
African American Male Leaders in Counseling: Interviews with Five AMCD Past Presidents
ERIC Educational Resources Information Center
Smith, Megan L.; Roysircar, Gargi
2010-01-01
Interviews with 5 African American male past presidents of the Association for Multicultural Counseling and Development provided insights into minority leadership. Among observed themes, a communal worldview permeated actions, historical events affected development, personal traits and external resources promoted resilience, and skin color…
Multicultural and Social Justice Counseling Competencies: Guidelines for the Counseling Profession
ERIC Educational Resources Information Center
Ratts, Manivong J.; Singh, Anneliese A.; Nassar-McMillan, Sylvia; Butler, S. Kent; McCullough, Julian Rafferty
2016-01-01
In 2014, the Association for Multicultural Counseling and Development (AMCD) appointed a committee to revise the Multicultural Counseling Competencies developed by Sue, Arredondo, and McDavis in 1992 and operationalized by Arredondo et al. in 1996. This article reflects the updated competencies, titled the Multicultural and Social Justice…
NASA Astrophysics Data System (ADS)
Staab, Maximilian; Kutnyakhov, Dmytro; Wallauer, Robert; Chernov, Sergey; Medjanik, Katerina; Elmers, Hans Joachim; Kläui, Mathias; Schönhense, Gerd
2017-04-01
The magnetic circular dichroism in threshold photoemission (TPMCD) for perpendicularly magnetized fcc Co films on Pt(111) has been revisited. A complete mapping of the spectral function I (EB,kx,ky) (binding energy EB, momentum parallel to surface kx, ky) and the corresponding TPMCD asymmetry distribution AMCD(EB,kx,ky) has been performed for one-photon and two-photon photoemission using time-of-flight momentum microscopy. The experimental results allow distinguishing direct from indirect transitions. The measurements reveal clear band features of direct transitions from bulk bands that show a nontrivial asymmetry pattern. A significant homogeneous background with substantial asymmetry stemming from indirect transitions superposes direct transitions. Two-photon photoemission reveals enhanced emission intensity via an image potential state, acting as intermediate state. The image potential state enhances not only intensity but also asymmetry. The present results demonstrate that two-photon photoemission is a powerful method for mapping the spin-polarized unoccupied band structures and points out pathways for applying TPMCD as a contrast mechanism for various classes of magnetic materials.
DeShong, J.A.
1960-03-01
A control-limiting device for monltoring a control system is described. The system comprises a conditionsensing device, a condition-varying device exerting a control over the condition, and a control means to actuate the condition-varying device. A control-limiting device integrates the total movement or other change of the condition-varying device over any interval of time during a continuum of overlapping periods of time, and if the tothl movement or change of the condition-varying device exceeds a preset value, the control- limiting device will switch the control of the operated apparatus from automatic to manual control.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-31
... traffic control device design, location, or operation that have made some existing devices in the field...-2010-0159] RIN 2125-AF43 National Standards for Traffic Control Devices; the Manual on Uniform Traffic Control Devices for Streets and Highways; Revision AGENCY: Federal Highway Administration (FHWA...
40 CFR 60.2141 - By what date must I conduct the initial air pollution control device inspection?
Code of Federal Regulations, 2011 CFR
2011-07-01
... air pollution control device inspection? 60.2141 Section 60.2141 Protection of Environment... initial air pollution control device inspection? (a) The initial air pollution control device inspection... startup. (b) Within 10 operating days following an air pollution control device inspection, all necessary...
40 CFR 60.2141 - By what date must I conduct the initial air pollution control device inspection?
Code of Federal Regulations, 2012 CFR
2012-07-01
... air pollution control device inspection? 60.2141 Section 60.2141 Protection of Environment... initial air pollution control device inspection? (a) The initial air pollution control device inspection... startup. (b) Within 10 operating days following an air pollution control device inspection, all necessary...
14 CFR 23.373 - Speed control devices.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Speed control devices. 23.373 Section 23....373 Speed control devices. If speed control devices (such as spoilers and drag flaps) are incorporated....441 and 23.443, with the device extended at speeds up to the placard device extended speed; and (b) If...
14 CFR 23.373 - Speed control devices.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Speed control devices. 23.373 Section 23....373 Speed control devices. If speed control devices (such as spoilers and drag flaps) are incorporated....441 and 23.443, with the device extended at speeds up to the placard device extended speed; and (b) If...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-14
...-2010-0159] RIN 2125-AF43 National Standards for Traffic Control Devices; the Manual on Uniform Traffic Control Devices for Streets and Highways; Revision AGENCY: Federal Highway Administration (FHWA..., approved by the FHWA, and recognized as the national standard for traffic control devices used on all...
Method and apparatus for actively controlling a micro-scale flexural plate wave device
Dohner, Jeffrey L.
2001-01-01
An actively controlled flexural plate wave device provides a micro-scale pump. A method of actively controlling a flexural plate wave device produces traveling waves in the device by coordinating the interaction of a magnetic field with actively controlled currents. An actively-controlled flexural plate wave device can be placed in a fluid channel and adapted for use as a micro-scale fluid pump to cool or drive micro-scale systems, for example, micro-chips, micro-electrical-mechanical devices, micro-fluid circuits, or micro-scale chemical analysis devices.
40 CFR 63.10010 - What are my monitoring, installation, operation, and maintenance requirements?
Code of Federal Regulations, 2013 CFR
2013-07-01
... that emissions are controlled with a common control device or series of control devices, are discharged... parallel control devices or multiple series of control devices are discharged to the atmosphere through... quality control activities (including, as applicable, calibration checks and required zero and span...
40 CFR 63.10010 - What are my monitoring, installation, operation, and maintenance requirements?
Code of Federal Regulations, 2014 CFR
2014-07-01
... that emissions are controlled with a common control device or series of control devices, are discharged... parallel control devices or multiple series of control devices are discharged to the atmosphere through... quality control activities (including, as applicable, calibration checks and required zero and span...
Local rollback for fault-tolerance in parallel computing systems
Blumrich, Matthias A [Yorktown Heights, NY; Chen, Dong [Yorktown Heights, NY; Gara, Alan [Yorktown Heights, NY; Giampapa, Mark E [Yorktown Heights, NY; Heidelberger, Philip [Yorktown Heights, NY; Ohmacht, Martin [Yorktown Heights, NY; Steinmacher-Burow, Burkhard [Boeblingen, DE; Sugavanam, Krishnan [Yorktown Heights, NY
2012-01-24
A control logic device performs a local rollback in a parallel super computing system. The super computing system includes at least one cache memory device. The control logic device determines a local rollback interval. The control logic device runs at least one instruction in the local rollback interval. The control logic device evaluates whether an unrecoverable condition occurs while running the at least one instruction during the local rollback interval. The control logic device checks whether an error occurs during the local rollback. The control logic device restarts the local rollback interval if the error occurs and the unrecoverable condition does not occur during the local rollback interval.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chernoguzov, Alexander; Markham, Thomas R.; Haridas, Harshal S.
A method includes generating at least one access vector associated with a specified device in an industrial process control and automation system. The specified device has one of multiple device roles. The at least one access vector is generated based on one or more communication policies defining communications between one or more pairs of devices roles in the industrial process control and automation system, where each pair of device roles includes the device role of the specified device. The method also includes providing the at least one access vector to at least one of the specified device and one ormore » more other devices in the industrial process control and automation system in order to control communications to or from the specified device.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-23
... test system into class II (special controls). The special control that will apply to these devices is the guidance document entitled ``Guidance for Industry and FDA Staff; Class II Special Controls... devices into class II (special controls) because special controls, in addition to general controls, will...
14 CFR 25.697 - Lift and drag devices, controls.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.697 Lift and drag devices, controls. (a) Each lift device control must be designed so that the pilots... drag device control must be designed and located to make inadvertent operation improbable. Lift and...
14 CFR 25.697 - Lift and drag devices, controls.
Code of Federal Regulations, 2012 CFR
2012-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.697 Lift and drag devices, controls. (a) Each lift device control must be designed so that the pilots... drag device control must be designed and located to make inadvertent operation improbable. Lift and...
14 CFR 25.697 - Lift and drag devices, controls.
Code of Federal Regulations, 2014 CFR
2014-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.697 Lift and drag devices, controls. (a) Each lift device control must be designed so that the pilots... drag device control must be designed and located to make inadvertent operation improbable. Lift and...
14 CFR 25.697 - Lift and drag devices, controls.
Code of Federal Regulations, 2011 CFR
2011-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.697 Lift and drag devices, controls. (a) Each lift device control must be designed so that the pilots... drag device control must be designed and located to make inadvertent operation improbable. Lift and...
Distributed solid state programmable thermostat/power controller
NASA Technical Reports Server (NTRS)
Smith, Dennis A. (Inventor); Alexander, Jane C. (Inventor); Howard, David E. (Inventor)
2008-01-01
A self-contained power controller having a power driver switch, programmable controller, communication port, and environmental parameter measuring device coupled to a controllable device. The self-contained power controller needs only a single voltage source to power discrete devices, analog devices, and the controlled device. The programmable controller has a run mode which, when selected, upon the occurrence of a trigger event changes the state of a power driver switch and wherein the power driver switch is maintained by the programmable controller at the same state until the occurrence of a second event.
40 CFR 63.8485 - What reports must I submit and when?
Code of Federal Regulations, 2010 CFR
2010-07-01
...). (5) A description of control device maintenance performed while the control device was offline and the kiln controlled by the control device was operating, including the information specified in paragraphs (c)(5)(i) through (iii) of this section. (i) The date and time when the control device was...
40 CFR 60.2706 - By what date must I conduct the initial air pollution control device inspection?
Code of Federal Regulations, 2012 CFR
2012-07-01
... air pollution control device inspection? 60.2706 Section 60.2706 Protection of Environment... pollution control device inspection? (a) The initial air pollution control device inspection must be... meeting the amended emission limitations. (b) Within 10 operating days following an air pollution control...
40 CFR 60.2706 - By what date must I conduct the initial air pollution control device inspection?
Code of Federal Regulations, 2014 CFR
2014-07-01
... air pollution control device inspection? 60.2706 Section 60.2706 Protection of Environment... pollution control device inspection? (a) The initial air pollution control device inspection must be... meeting the amended emission limitations. (b) Within 10 operating days following an air pollution control...
40 CFR 60.2706 - By what date must I conduct the initial air pollution control device inspection?
Code of Federal Regulations, 2013 CFR
2013-07-01
... air pollution control device inspection? 60.2706 Section 60.2706 Protection of Environment... pollution control device inspection? (a) The initial air pollution control device inspection must be... meeting the amended emission limitations. (b) Within 10 operating days following an air pollution control...
Daylight control system device and method
Paton, John Douglas
2007-03-13
A system and device for and a method of programming and controlling light fixtures is disclosed. A system in accordance with the present invention includes a stationary controller unit that is electrically coupled to the light fixtures. The stationary controller unit is configured to be remotely programmed with a portable commissioning device to automatically control the lights fixtures. The stationary controller unit and the portable commissioning device include light sensors, micro-computers and transceivers for measuring light levels, running programs, storing data and transmitting data between the stationary controller unit and the portable commissioning device. In operation, target light levels selected with the portable commissioning device and the controller unit is remotely programmed to automatically maintain the target level.
Daylight control system, device and method
Paton, John Douglas
2012-08-28
A system and device for and a method of programming and controlling light fixtures is disclosed. A system in accordance with the present invention includes a stationary controller unit that is electrically coupled to the light fixtures. The stationary controller unit is configured to be remotely programmed with a portable commissioning device to automatically control the lights fixtures. The stationary controller unit and the portable commissioning device include light sensors, micro-computers and transceivers for measuring light levels, running programs, storing data and transmitting data between the stationary controller unit and the portable commissioning device. In operation, target light levels selected with the portable commissioning device and the controller unit is remotely programmed to automatically maintain the target level.
Daylight control system device and method
Paton, John Douglas
2009-12-01
A system and device for and a method of programming and controlling light fixtures is disclosed. A system in accordance with the present invention includes a stationary controller unit that is electrically coupled to the light fixtures. The stationary controller unit is configured to be remotely programmed with a portable commissioning device to automatically control the lights fixtures. The stationary controller unit and the portable commissioning device include light sensors, micro-computers and transceivers for measuring light levels, running programs, storing data and transmitting data between the stationary controller unit and the portable commissioning device. In operation, target light levels selected with the portable commissioning device and the controller unit is remotely programmed to automatically maintain the target level.
A generic approach for examining the effectiveness of traffic control devices in school zones.
Zhao, Xiaohua; Li, Jiahui; Ding, Han; Zhang, Guohui; Rong, Jian
2015-09-01
The effectiveness and performance of traffic control devices in school zones have been impacted significantly by many factors, such as driver behavioral attributes, roadway geometric features, environmental characteristics, weather and visibility conditions, region-wide traffic regulations and policies, control modes, etc. When deploying traffic control devices in school zones, efforts are needed to clarify: (1) whether traffic control device installation is warranted; and (2) whether other device effectively complements this traffic control device and strengthens its effectiveness. In this study, a generic approach is developed to examine and evaluate the effectiveness of various traffic control devices deployed in school zones through driving simulator-based experiments. A Traffic Control Device Selection Model (TCDSM) is developed and two representative school zones are selected as the testbed in Beijing for driving simulation implementation to enhance its applicability. Statistical analyses are conducted to extract the knowledge from test data recorded by a driving simulator. Multiple measures of effectiveness (MOEs) are developed and adopted including average speed, relative speed difference, and standard deviation of acceleration for traffic control device performance quantification. The experimental tests and analysis results reveal that the appropriateness of the installation of certain traffic control devices can be statistically verified by TCDSM. The proposed approach provides a generic framework to assess traffic control device performance in school zones including experiment design, statistical formulation, data analysis, simulation model implementation, data interpretation, and recommendation development. Copyright © 2015 Elsevier Ltd. All rights reserved.
Systems, methods, and products for graphically illustrating and controlling a droplet actuator
NASA Technical Reports Server (NTRS)
Brafford, Keith R. (Inventor); Pamula, Vamsee K. (Inventor); Paik, Philip Y. (Inventor); Pollack, Michael G. (Inventor); Sturmer, Ryan A. (Inventor); Smith, Gregory F. (Inventor)
2010-01-01
Systems for controlling a droplet microactuator are provided. According to one embodiment, a system is provided and includes a controller, a droplet microactuator electronically coupled to the controller, and a display device displaying a user interface electronically coupled to the controller, wherein the system is programmed and configured to permit a user to effect a droplet manipulation by interacting with the user interface. According to another embodiment, a system is provided and includes a processor, a display device electronically coupled to the processor, and software loaded and/or stored in a storage device electronically coupled to the controller, a memory device electronically coupled to the controller, and/or the controller and programmed to display an interactive map of a droplet microactuator. According to yet another embodiment, a system is provided and includes a controller, a droplet microactuator electronically coupled to the controller, a display device displaying a user interface electronically coupled to the controller, and software for executing a protocol loaded and/or stored in a storage device electronically coupled to the controller, a memory device electronically coupled to the controller, and/or the controller.
40 CFR 63.5767 - What records must I keep?
Code of Federal Regulations, 2013 CFR
2013-07-01
... facility is not controlled by an add-on control device (i.e., you are complying with organic HAP content... add-on control device, you must keep the records specified in § 63.10(b) relative to control device startup, shut down, and malfunction events; control device performance tests; and continuous monitoring...
40 CFR 63.5767 - What records must I keep?
Code of Federal Regulations, 2012 CFR
2012-07-01
... facility is not controlled by an add-on control device (i.e., you are complying with organic HAP content... add-on control device, you must keep the records specified in § 63.10(b) relative to control device startup, shut down, and malfunction events; control device performance tests; and continuous monitoring...
40 CFR 63.5767 - What records must I keep?
Code of Federal Regulations, 2014 CFR
2014-07-01
... facility is not controlled by an add-on control device (i.e., you are complying with organic HAP content... add-on control device, you must keep the records specified in § 63.10(b) relative to control device startup, shut down, and malfunction events; control device performance tests; and continuous monitoring...
40 CFR 63.10010 - What are my monitoring, installation, operation, and maintenance requirements?
Code of Federal Regulations, 2012 CFR
2012-07-01
... emissions are controlled with a common control device or series of control devices, are discharged to the... devices or multiple series of control devices are discharged to the atmosphere through more than one stack... control activities (including, as applicable, calibration checks and required zero and span adjustments...
40 CFR 65.152 - Carbon adsorbers used as control devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... control device. If an owner or operator elects to replace a control device on a Group 1 process vent or... 40 Protection of Environment 15 2011-07-01 2011-07-01 false Carbon adsorbers used as control... PROGRAMS (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a...
40 CFR 60.2151 - By what date must I conduct the annual air pollution control device inspection?
Code of Federal Regulations, 2011 CFR
2011-07-01
... air pollution control device inspection? 60.2151 Section 60.2151 Protection of Environment... annual air pollution control device inspection? On an annual basis (no more than 12 months following the previous annual air pollution control device inspection), you must complete the air pollution control...
40 CFR 63.8635 - What reports must I submit and when?
Code of Federal Regulations, 2010 CFR
2010-07-01
... description of control device maintenance performed while the control device was offline and the kiln controlled by the control device was operating, including the information specified in paragraphs (c)(5)(i) through (iii) of this section. (i) The date and time when the control device was shutdown and restarted...
40 CFR 63.2281 - What reports must I submit and when?
Code of Federal Regulations, 2010 CFR
2010-07-01
... description of control device maintenance performed while the control device was offline and one or more of the process units controlled by the control device was operating, including the information specified in paragraphs (c)(5)(i) through (iii) of this section. (i) The date and time when the control device...
40 CFR 60.2151 - By what date must I conduct the annual air pollution control device inspection?
Code of Federal Regulations, 2012 CFR
2012-07-01
... air pollution control device inspection? 60.2151 Section 60.2151 Protection of Environment... annual air pollution control device inspection? On an annual basis (no more than 12 months following the previous annual air pollution control device inspection), you must complete the air pollution control...
2014-10-22
The Food and Drug Administration (FDA) is classifying nucleic acid-based in vitro diagnostic devices for the detection of Mycobacterium tuberculosis complex (MTB-complex) and the genetic mutations associated with MTB-complex antibiotic resistance in respiratory specimens devices into class II (special controls). The Agency is classifying the device into class II (special controls) because special controls, in addition to general controls, will provide a reasonable assurance of safety and effectiveness of the device.
Communicating with residential electrical devices via a vehicle telematics unit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roth, Rebecca C.; Pebbles, Paul H.
A method of communicating with residential electrical devices using a vehicle telematics unit includes receiving information identifying a residential electrical device to control; displaying in a vehicle one or more controlled features of the identified residential electrical device; receiving from a vehicle occupant a selection of the displayed controlled features of the residential electrical device; sending an instruction from the vehicle telematics unit to the residential electrical device via a wireless carrier system in response to the received selection; and controlling the residential electrical device using the sent instruction.
21 CFR 870.1290 - Steerable catheter control system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Steerable catheter control system. 870.1290... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1290 Steerable catheter control system. (a) Identification. A steerable catheter control system is a device that is...
21 CFR 870.1290 - Steerable catheter control system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Steerable catheter control system. 870.1290... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1290 Steerable catheter control system. (a) Identification. A steerable catheter control system is a device that is...
21 CFR 870.1290 - Steerable catheter control system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Steerable catheter control system. 870.1290... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1290 Steerable catheter control system. (a) Identification. A steerable catheter control system is a device that is...
2010-11-05
The Food and Drug Administration (FDA) is announcing the reclassification of the full-field digital mammography (FFDM) system from class III (premarket approval) to class II (special controls). The device type is intended to produce planar digital x-ray images of the entire breast; this generic type of device may include digital mammography acquisition software, full-field digital image receptor, acquisition workstation, automatic exposure control, image processing and reconstruction programs, patient and equipment supports, component parts, and accessories. The special control that will apply to the device is the guidance document entitled "Class II Special Controls Guidance Document: Full-Field Digital Mammography System." FDA is reclassifying the device into class II (special controls) because general controls along with special controls will provide a reasonable assurance of safety and effectiveness of the device. Elsewhere in this issue of the Federal Register, FDA is announcing the availability of the guidance document that will serve as the special control for this device.
Evaluation of an investigational wearable injector in healthy human volunteers.
Torjman, Marc C; Machnicki, Robert; Lessin, Jennifer; Loeum, Channy; Steinberger, Douglas; Mycroft, Sarah; Joseph, Jeffrey I
2017-01-01
Introduction of a wearable device for subcutaneous delivery of larger volume bolus injections would encourage patient compliance and reduce the burden on healthcare services. With one such wearable device commercially available, this study examined the safety and functionality of an investigational device in volunteers. Four devices were applied to the subject's abdomen: 1) Investigational Device, 2) Investigational Device: subject movement, 3) Control Device: FDA-cleared syringe driver with FDA-cleared infusion set, 4) Control Device: FDA-cleared syringe driver attached to investigational device. Three milliliters of saline were infused through the four devices over 3 minutes. 84 devices were applied to 21 subjects. Three milliliters of saline were safely delivered subcutaneously from the investigational and control devices. Two control devices had occlusions and in each case the pump reached its high pressure limit of 12 psi. VAS pain measurements showed minimal pain for all subjects. Pain scores were significantly (p < 0.001) higher than baseline at the end of injection: mean pain level ranged from 2.0-22.0 mm. The investigational device performed as intended with minimal pain during needle insertion and infusion, and no leaking of fluid at the skin puncture site. Two occlusions occurred with the control devices.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-14
... into class II (special controls). The special control(s) that will apply to the device is entitled ``Class II Special Controls Guidance Document: Low Level Laser System for Aesthetic Use.'' The Agency is classifying the device into class II (special controls) in order to provide a reasonable assurance of safety...
Intermittent patient suction system, self-contained control
Lewis, Jay L.
1992-01-01
An intermittent patient suction system, a self-contained control device therefor and methods of making the same are provided, the self-contained control device having a housing that contains two restrictor units therein for respectively controlling the "on" time and "off" time that the control device applies a vacuum and does not apply a vacuum through the output of the control device to the patient.
21 CFR 870.4300 - Cardiopulmonary bypass gas control unit.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiopulmonary bypass gas control unit. 870.4300... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Surgical Devices § 870.4300 Cardiopulmonary bypass gas control unit. (a) Identification. A cardiopulmonary bypass gas control unit is a device used...
21 CFR 870.4300 - Cardiopulmonary bypass gas control unit.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass gas control unit. 870.4300... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Surgical Devices § 870.4300 Cardiopulmonary bypass gas control unit. (a) Identification. A cardiopulmonary bypass gas control unit is a device used...
40 CFR 1700.14 - Marine Pollution Control Device (MPCD) Performance Standards. [Reserved
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Marine Pollution Control Device (MPCD... UNIFORM NATIONAL DISCHARGE STANDARDS FOR VESSELS OF THE ARMED FORCES Marine Pollution Control Device (MPCD) Performance Standards § 1700.14 Marine Pollution Control Device (MPCD) Performance Standards. [Reserved] ...
40 CFR 1700.14 - Marine Pollution Control Device (MPCD) Performance Standards. [Reserved
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Marine Pollution Control Device (MPCD... UNIFORM NATIONAL DISCHARGE STANDARDS FOR VESSELS OF THE ARMED FORCES Marine Pollution Control Device (MPCD) Performance Standards § 1700.14 Marine Pollution Control Device (MPCD) Performance Standards. [Reserved] ...
40 CFR 1700.14 - Marine Pollution Control Device (MPCD) Performance Standards. [Reserved
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Marine Pollution Control Device (MPCD... UNIFORM NATIONAL DISCHARGE STANDARDS FOR VESSELS OF THE ARMED FORCES Marine Pollution Control Device (MPCD) Performance Standards § 1700.14 Marine Pollution Control Device (MPCD) Performance Standards. [Reserved] ...
Code of Federal Regulations, 2011 CFR
2011-07-01
... flue gases at the inlet of my particulate matter control device? 60.1325 Section 60.1325 Protection of... the inlet of my particulate matter control device? You must install, calibrate, maintain, and operate... particulate matter control device. ...
Code of Federal Regulations, 2010 CFR
2010-07-01
... flue gases at the inlet of my particulate matter control device? 60.1325 Section 60.1325 Protection of... the inlet of my particulate matter control device? You must install, calibrate, maintain, and operate... particulate matter control device. ...
40 CFR 1700.14 - Marine Pollution Control Device (MPCD) Performance Standards. [Reserved
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 33 2011-07-01 2011-07-01 false Marine Pollution Control Device (MPCD... UNIFORM NATIONAL DISCHARGE STANDARDS FOR VESSELS OF THE ARMED FORCES Marine Pollution Control Device (MPCD) Performance Standards § 1700.14 Marine Pollution Control Device (MPCD) Performance Standards. [Reserved] ...
40 CFR 1700.14 - Marine Pollution Control Device (MPCD) Performance Standards. [Reserved
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Marine Pollution Control Device (MPCD... UNIFORM NATIONAL DISCHARGE STANDARDS FOR VESSELS OF THE ARMED FORCES Marine Pollution Control Device (MPCD) Performance Standards § 1700.14 Marine Pollution Control Device (MPCD) Performance Standards. [Reserved] ...
14 CFR 25.373 - Speed control devices.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Speed control devices. 25.373 Section 25... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Structure Supplementary Conditions § 25.373 Speed control devices. If speed control devices (such as spoilers and drag flaps) are installed for use in en route...
14 CFR 25.373 - Speed control devices.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Speed control devices. 25.373 Section 25... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Structure Supplementary Conditions § 25.373 Speed control devices. If speed control devices (such as spoilers and drag flaps) are installed for use in en route...
40 CFR 60.2716 - By what date must I conduct the annual air pollution control device inspection?
Code of Federal Regulations, 2014 CFR
2014-07-01
... air pollution control device inspection? 60.2716 Section 60.2716 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY... annual air pollution control device inspection), you must complete the air pollution control device...
40 CFR 60.2716 - By what date must I conduct the annual air pollution control device inspection?
Code of Federal Regulations, 2012 CFR
2012-07-01
... air pollution control device inspection? 60.2716 Section 60.2716 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY... annual air pollution control device inspection), you must complete the air pollution control device...
40 CFR 60.2716 - By what date must I conduct the annual air pollution control device inspection?
Code of Federal Regulations, 2013 CFR
2013-07-01
... air pollution control device inspection? 60.2716 Section 60.2716 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY... annual air pollution control device inspection), you must complete the air pollution control device...
2017-07-27
The Food and Drug Administration (FDA, Agency, or we) is classifying the assayed quality control material for clinical microbiology assays into class II (special controls). The special controls that will apply to the device are identified in this order and will be part of the codified language for the assayed quality control material for clinical microbiology assays' classification. The Agency is classifying the device into class II (special controls) to provide a reasonable assurance of safety and effectiveness of the device.
Method for triggering an action
Hall, David R.; Bartholomew, David B.; Johnson, Monte L.; Moon, Justin; Koehler, Roger O.
2006-10-17
A method for triggering an action of at least one downhole device on a downhole network integrated into a downhole tool string synchronized to an event comprises determining latency, sending a latency adjusted signal, and performing the action. The latency is determined between a control device and the at least one downhole device. The latency adjusted signal for triggering an action is sent to the downhole device. The action is performed downhole synchronized to the event. A preferred method for determining latency comprises the steps: a control device sends a first signal to the downhole device; after receiving the signal, the downhole device sends a response signal to the control device; and the control device analyzes the time from sending the signal to receiving the response signal.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bolenbaugh, Jonathan M.; Naqi, Syed
A method to operate a clutch device in an electro-mechanical transmission mechanically-operatively coupled to an internal combustion engine and at least one electric machine includes, in response to a failure condition detected within a flow control device configured to facilitate flow of hydraulic fluid for operating the clutch device, selectively preventing the flow of hydraulic fluid from entering the flow control device and feeding the clutch device. Synchronization of the clutch device is initiated when the clutch device is intended for activation, and only if the clutch device is synchronized, the flow of hydraulic fluid is selectively permitted to entermore » the flow control device to activate the clutch device.« less
21 CFR 870.3535 - Intra-aortic balloon and control system
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Intra-aortic balloon and control system 870.3535... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3535 Intra-aortic balloon and control system (a) Identification. A intra-aortic balloon and control system is a device that...
21 CFR 870.3535 - Intra-aortic balloon and control system
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Intra-aortic balloon and control system 870.3535... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3535 Intra-aortic balloon and control system (a) Identification. A intra-aortic balloon and control system is a device that...
40 CFR 63.2251 - What are the requirements for the routine control device maintenance exemption?
Code of Federal Regulations, 2010 CFR
2010-07-01
... the routine control device maintenance exemption? (a) You may request a routine control device..., explain why the maintenance cannot be accomplished during process shutdowns, describe how you plan to make... device is used to control a green rotary dryer, tube dryer, rotary strand dryer, or pressurized refiner...
40 CFR 65.150 - Absorbers used as control devices.
Code of Federal Regulations, 2014 CFR
2014-07-01
... control device on a Group 1 process vent or a high-throughput transfer rack with an absorber used as a... 40 Protection of Environment 16 2014-07-01 2014-07-01 false Absorbers used as control devices. 65... (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas...
40 CFR 65.150 - Absorbers used as control devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... control device on a Group 1 process vent or a high-throughput transfer rack with an absorber used as a... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Absorbers used as control devices. 65... (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas...
40 CFR 65.150 - Absorbers used as control devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... control device on a Group 1 process vent or a high-throughput transfer rack with an absorber used as a... 40 Protection of Environment 15 2011-07-01 2011-07-01 false Absorbers used as control devices. 65... (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas...
Code of Federal Regulations, 2011 CFR
2011-07-01
... electric furnaces with wet air pollution control devices subcategory. 424.10 Section 424.10 Protection of... MANUFACTURING POINT SOURCE CATEGORY Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory § 424.10 Applicability; description of the open electric furnaces with wet air pollution control devices...
Code of Federal Regulations, 2010 CFR
2010-07-01
... electric furnaces with wet air pollution control devices subcategory. 424.10 Section 424.10 Protection of... MANUFACTURING POINT SOURCE CATEGORY Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory § 424.10 Applicability; description of the open electric furnaces with wet air pollution control devices...
40 CFR 60.2141 - By what date must I conduct the initial air pollution control device inspection?
Code of Federal Regulations, 2013 CFR
2013-07-01
... air pollution control device inspection? 60.2141 Section 60.2141 Protection of Environment... Compliance Requirements § 60.2141 By what date must I conduct the initial air pollution control device inspection? (a) The initial air pollution control device inspection must be conducted within 60 days after...
Code of Federal Regulations, 2013 CFR
2013-07-01
... electric furnaces with wet air pollution control devices subcategory. 424.10 Section 424.10 Protection of... MANUFACTURING POINT SOURCE CATEGORY Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory § 424.10 Applicability; description of the open electric furnaces with wet air pollution control devices...
Code of Federal Regulations, 2014 CFR
2014-07-01
... electric furnaces with wet air pollution control devices subcategory. 424.10 Section 424.10 Protection of... MANUFACTURING POINT SOURCE CATEGORY Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory § 424.10 Applicability; description of the open electric furnaces with wet air pollution control devices...
Code of Federal Regulations, 2012 CFR
2012-07-01
... electric furnaces with wet air pollution control devices subcategory. 424.10 Section 424.10 Protection of... MANUFACTURING POINT SOURCE CATEGORY Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory § 424.10 Applicability; description of the open electric furnaces with wet air pollution control devices...
40 CFR 60.2141 - By what date must I conduct the initial air pollution control device inspection?
Code of Federal Regulations, 2014 CFR
2014-07-01
... air pollution control device inspection? 60.2141 Section 60.2141 Protection of Environment... Compliance Requirements § 60.2141 By what date must I conduct the initial air pollution control device inspection? (a) The initial air pollution control device inspection must be conducted within 60 days after...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-30
... balloon and control system (IABP) devices when indicated for acute coronary syndrome, cardiac and non... and non-cardiac surgery, or complications of heart failure. The special controls for this device are.... FDA-2013-N-0581] Cardiovascular Devices; Reclassification of Intra-Aortic Balloon and Control Systems...
Control method for physical systems and devices
Guckenheimer, John
1997-01-01
A control method for stabilizing systems or devices that are outside the control domain of a linear controller is provided. When applied to nonlinear systems, the effectiveness of this method depends upon the size of the domain of stability that is produced for the stabilized equilibrium. If this domain is small compared to the accuracy of measurements or the size of disturbances within the system, then the linear controller is likely to fail within a short period. Failure of the system or device can be catastrophic: the system or device can wander far from the desired equilibrium. The method of the invention presents a general procedure to recapture the stability of a linear controller, when the trajectory of a system or device leaves its region of stability. By using a hybrid strategy based upon discrete switching events within the state space of the system or device, the system or device will return from a much larger domain to the region of stability utilized by the linear controller. The control procedure is robust and remains effective under large classes of perturbations of a given underlying system or device.
2015-11-20
The Food and Drug Administration (FDA or the Agency) is classifying the ultraviolet (UV) radiation chamber disinfection device into class II (special controls). The special controls that will apply to the device are identified in this order and will be part of the codified language for the UV radiation chamber disinfection device classification. The Agency is classifying the device into class II (special controls) in order to provide a reasonable assurance of safety and effectiveness of the device.
Hooper, Bethany; Verdonck, Michele; Amsters, Delena; Myburg, Michelle; Allan, Emily
2017-09-06
Environmental control systems (ECS) are devices that enable people with severe physical limitations to independently control household appliances. Recent advancements in the area of environmental control technology have led to the development of ECS that can be controlled through mainstream smart-devices. There is limited research on ECS within Australia and no known research addressing smart-device ECS. The current study sought to explore users' experiences with smart-device ECS within Australia. The study followed a single embedded case study method. Participants (n = 5) were existing ECS users with a cervical spinal cord injury. Data were collected through semi-structured interviews with participants, reflexive journals and field notes. An inductive approach was used to analyze the data thematically. The experience of using a smart-device ECS presented both opportunities and costs to users. The opportunities included: independent control, choice, peace of mind, connection, effective resource use, and control over smart-phone functions and applications. The associated costs included: financial, time, frustration, and technical limitations. While findings are similar to previous research into traditional ECS this study indicates that smart-device ECS also offered a new opportunity for users to access mainstream smart-device functions and applications. Future research should investigate methods and resources that practitioners could utilize to better support new users of smart-device ECS. Implications for Rehabilitation As with traditional environmental control systems, users of smart environmental control systems report increased independence, choice and control. Smart-device environmental control systems provide users with access to mainstream smart-device functions and applications, which facilitate connection to family and the outside world. The costs to the user of smart-device environmental control systems include monetary and time investment, dealing with technical limitations and resulting frustration. Prescribers and installers must consider ways to mitigate these costs experienced by users.
2007-02-01
The Food and Drug Administration (FDA) is classifying a cord blood processing system and storage container into class II (special controls). The special control that will apply to this device is the guidance document entitled "Class II Special Controls Guidance Document: Cord Blood Processing System and Storage Container." FDA is classifying this device into class II (special controls) in order to provide a reasonable assurance of safety and effectiveness of this device. Elsewhere in this issue of the Federal Register, FDA is announcing the availability of the guidance document that will serve as the special control for this device.
Interdependent networks: the fragility of control
Morris, Richard G.; Barthelemy, Marc
2013-01-01
Recent work in the area of interdependent networks has focused on interactions between two systems of the same type. However, an important and ubiquitous class of systems are those involving monitoring and control, an example of interdependence between processes that are very different. In this Article, we introduce a framework for modelling ‘distributed supervisory control' in the guise of an electrical network supervised by a distributed system of control devices. The system is characterised by degrees of freedom salient to real-world systems— namely, the number of control devices, their inherent reliability, and the topology of the control network. Surprisingly, the behavior of the system depends crucially on the reliability of control devices. When devices are completely reliable, cascade sizes are percolation controlled; the number of devices being the relevant parameter. For unreliable devices, the topology of the control network is important and can dramatically reduce the resilience of the system. PMID:24067404
2004-03-16
The Food and Drug Administration (FDA) is classifying the Factor V Leiden deoxyribonucleic acid (DNA) mutation detections systems device into class II (special controls). The special control that will apply to the device is the guidance document entitled "Class II Special Controls Guidance Document: Factor V Leiden DNA Mutation Detection Systems." The agency is taking this action in response to a petition submitted under the Federal Food, Drug, and Cosmetic Act (the act) as amended by the Medical Device Amendments of 1976 (the 1976 amendments), the Safe Medical Devices Act of 1990 (SMDA), the Food and Drug Administration Modernization Act of 1997 (FDAMA), and the Medical Device User Fee and Modernization Act of 2002. The agency is classifying this device into class II (special controls) in order to provide a reasonable assurance of safety and effectiveness of the device. Elsewhere in this issue of the Federal Register, FDA is publishing a notice of availability of a guidance document that is the special control for this device.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-14
... Options for design and applications of traffic control devices, this Manual should not be considered a... application of traffic control devices, as well as in the location and design of roads and streets that the..., while this Manual provides Standards, Guidance, and Options for design and applications of traffic...
Code of Federal Regulations, 2011 CFR
2011-07-01
... pollution control device inspections and make any necessary repairs? 60.5215 Section 60.5215 Protection of... air pollution control device inspections and make any necessary repairs? (a) You must conduct an annual inspection of each air pollution control device used to comply with the emission limits, according...
40 CFR 60.2716 - By what date must I conduct the annual air pollution control device inspection?
Code of Federal Regulations, 2011 CFR
2011-07-01
... air pollution control device inspection? 60.2716 Section 60.2716 Protection of Environment... Requirements § 60.2716 By what date must I conduct the annual air pollution control device inspection? On an annual basis (no more than 12 months following the previous annual air pollution control device...
40 CFR 60.2706 - By what date must I conduct the initial air pollution control device inspection?
Code of Federal Regulations, 2011 CFR
2011-07-01
... air pollution control device inspection? 60.2706 Section 60.2706 Protection of Environment... Requirements § 60.2706 By what date must I conduct the initial air pollution control device inspection? (a) The initial air pollution control device inspection must be conducted within 60 days after installation of the...
Portable control device for networked mobile robots
Feddema, John T.; Byrne, Raymond H.; Bryan, Jon R.; Harrington, John J.; Gladwell, T. Scott
2002-01-01
A handheld control device provides a way for controlling one or multiple mobile robotic vehicles by incorporating a handheld computer with a radio board. The device and software use a personal data organizer as the handheld computer with an additional microprocessor and communication device on a radio board for use in controlling one robot or multiple networked robots.
40 CFR 62.14441 - When must I inspect my HMIWI equipment and air pollution control devices?
Code of Federal Regulations, 2014 CFR
2014-07-01
... and air pollution control devices? 62.14441 Section 62.14441 Protection of Environment ENVIRONMENTAL... my HMIWI equipment and air pollution control devices? (a) You must inspect your large, medium, small... inspect the air pollution control devices on your large, medium, small or small rural HMIWI by May 13...
40 CFR 62.14441 - When must I inspect my HMIWI equipment and air pollution control devices?
Code of Federal Regulations, 2013 CFR
2013-07-01
... and air pollution control devices? 62.14441 Section 62.14441 Protection of Environment ENVIRONMENTAL... my HMIWI equipment and air pollution control devices? (a) You must inspect your large, medium, small... inspect the air pollution control devices on your large, medium, small or small rural HMIWI by May 13...
Code of Federal Regulations, 2014 CFR
2014-07-01
... air pollution control device inspection and make any necessary repairs? 60.5195 Section 60.5195... air pollution control device inspection and make any necessary repairs? (a) You must conduct an air... approved state plan, Federal plan, or delegation, as applicable. For air pollution control devices...
Code of Federal Regulations, 2013 CFR
2013-07-01
... air pollution control device inspection and make any necessary repairs? 60.5195 Section 60.5195... air pollution control device inspection and make any necessary repairs? (a) You must conduct an air... approved state plan, Federal plan, or delegation, as applicable. For air pollution control devices...
Code of Federal Regulations, 2012 CFR
2012-07-01
... air pollution control device inspection and make any necessary repairs? 60.5195 Section 60.5195... air pollution control device inspection and make any necessary repairs? (a) You must conduct an air... approved state plan, Federal plan, or delegation, as applicable. For air pollution control devices...
STS-43 Commander Blaha conducts DTO 1208 using laptop on OV-104's flight deck
1991-08-11
STS043-03-009 (5 Aug 1991) ---- Astronaut John E. Blaha is pictured executing development test objective (DTO) 1208, Space Station Cursor Control Device Evaluation II and advanced applications. The purpose of the Cursor Control Device Experiment is to evaluate human performance under space flight conditions of cursor control devices which are similar to the devices under consideration for use onboard Space Station computers. Here, the mission commander uses a thumbball/handgrip control device. Each crewmember evaluated the different types of cursor control devices during the nine-day STS-43 mission. Other methods of cursor control evaluated were the built-in trackball, a side mounted trackball with restraints and an optical pad with mouse.
STS-43 MS Adamson conducts DTO 1208 using laptop on OV-104's flight deck
1991-08-11
STS043-14-034 (2-11 Aug 1991) --- Astronaut James C. Adamson is pictured executing Development Test Objective (DTO) 1208, Space Station Cursor Control Device Evaluation II and Advanced Applications. The purpose of the Cursor Control Device Experiment is to evaluate human performance under space flight conditions of cursor control devices which are similar to the devices under consideration for use onboard space station computers. Here, the mission specialists uses a thumbball/handgrip control device. Each crewmember evaluated the different types of cursor control devices during the nine-day STS-43 mission. Other methods of cursor control evaluated were the built-in trackball, a side mounted trackball with restraints and an optical pad with mouse.
40 CFR 86.1803-01 - Definitions.
Code of Federal Regulations, 2014 CFR
2014-07-01
.... Auxiliary Emission Control Device (AECD) means any element of design which senses temperature, vehicle speed.... Critical emission-related components are those components which are designed primarily for emission control... control system is a unique group of emission control devices, auxiliary emission control devices, engine...
Code of Federal Regulations, 2014 CFR
2014-07-01
... that transport gas or vapor from a piece or pieces of equipment to a control device. Continuous... essentially continuously. Control device means an enclosed combustion device, vapor recovery system, or flare... have one or more end finishers. Existing control device means, for the purposes of these standards, an...
Code of Federal Regulations, 2013 CFR
2013-07-01
... that transport gas or vapor from a piece or pieces of equipment to a control device. Continuous... essentially continuously. Control device means an enclosed combustion device, vapor recovery system, or flare... have one or more end finishers. Existing control device means, for the purposes of these standards, an...
Non-synchronous control of self-oscillating resonant converters
Glaser, John Stanley; Zane, Regan Andrew
2002-01-01
A self-oscillating switching power converter has a controllable reactance including an active device connected to a reactive element, wherein the effective reactance of the reactance and the active device is controlled such that the control waveform for the active device is binary digital and is not synchronized with the switching converter output frequency. The active device is turned completely on and off at a frequency that is substantially greater than the maximum frequency imposed on the output terminals of the active device. The effect is to vary the average resistance across the active device output terminals, and thus the effective output reactance, thereby providing converter output control, while maintaining the response speed of the converter.
40 CFR 65.155 - Other control devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas System or a Process § 65.155 Other control devices. (a) Other control device equipment and operating requirements. (1... requirements specified in § 65.63(a)(2), or 40 CFR 60.562-1(a)(1)(i)(A) for process vents, or § 65.83(a)(1) for...
Code of Federal Regulations, 2011 CFR
2011-07-01
... flue gases at the inlet of my particulate matter control device? 60.1815 Section 60.1815 Protection of... I monitor the temperature of flue gases at the inlet of my particulate matter control device? You... flue gas stream at the inlet of each particulate matter control device. ...
Code of Federal Regulations, 2010 CFR
2010-07-01
... flue gases at the inlet of my particulate matter control device? 60.1815 Section 60.1815 Protection of... I monitor the temperature of flue gases at the inlet of my particulate matter control device? You... flue gas stream at the inlet of each particulate matter control device. ...
Code of Federal Regulations, 2011 CFR
2011-07-01
... air pollution control device inspection and make any necessary repairs? 60.5195 Section 60.5195... air pollution control device inspection and make any necessary repairs? (a) You must conduct an air pollution control device inspection according to § 60.5220(c) by the final compliance date under the...
Code of Federal Regulations, 2011 CFR
2011-07-01
... air pollution control device inspection and make any necessary repairs? 60.4875 Section 60.4875... Initial Compliance Requirements § 60.4875 By what date must I conduct the initial air pollution control device inspection and make any necessary repairs? (a) You must conduct an air pollution control device...
Code of Federal Regulations, 2014 CFR
2014-07-01
... air pollution control device inspection and make any necessary repairs? 60.4875 Section 60.4875... Initial Compliance Requirements § 60.4875 By what date must I conduct the initial air pollution control device inspection and make any necessary repairs? (a) You must conduct an air pollution control device...
Code of Federal Regulations, 2013 CFR
2013-07-01
... air pollution control device inspection and make any necessary repairs? 60.4875 Section 60.4875... Initial Compliance Requirements § 60.4875 By what date must I conduct the initial air pollution control device inspection and make any necessary repairs? (a) You must conduct an air pollution control device...
Code of Federal Regulations, 2014 CFR
2014-07-01
... air pollution control device inspections and make any necessary repairs? (a) You must conduct an annual inspection of each air pollution control device used to comply with the emission limits, according to § 60.5220(c), no later than 12 months following the previous annual air pollution control device...
Code of Federal Regulations, 2012 CFR
2012-07-01
... air pollution control device inspection and make any necessary repairs? 60.4875 Section 60.4875... Initial Compliance Requirements § 60.4875 By what date must I conduct the initial air pollution control device inspection and make any necessary repairs? (a) You must conduct an air pollution control device...
Code of Federal Regulations, 2013 CFR
2013-07-01
... air pollution control device inspections and make any necessary repairs? (a) You must conduct an annual inspection of each air pollution control device used to comply with the emission limits, according to § 60.5220(c), no later than 12 months following the previous annual air pollution control device...
Code of Federal Regulations, 2012 CFR
2012-07-01
... air pollution control device inspections and make any necessary repairs? (a) You must conduct an annual inspection of each air pollution control device used to comply with the emission limits, according to § 60.5220(c), no later than 12 months following the previous annual air pollution control device...
77 FR 36951 - Gastroenterology-Urology Devices; Reclassification of Implanted Blood Access Devices
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-20
... into class II (special controls). FDA is proposing this reclassification on its own initiative based on... categories (classes) of devices, reflecting the regulatory controls needed to provide reasonable assurance of their safety and effectiveness. The three categories of devices are class I (general controls), class II...
Re-active Passive (RAP) Devices for Control of Noise Transmission through a Panel
NASA Technical Reports Server (NTRS)
Carneal, James P.; Giovanardi, Marco; Fuller, Chris R.; Palumbo, Daniel L.
2008-01-01
Re-Active Passive (RAP) devices have been developed to control low frequency (<1000 Hz) noise transmission through a panel. These devices use a combination of active, re-active, and passive technologies packaged into a single unit to control a broad frequency range utilizing the strength of each technology over its best suited frequency range. The RAP device uses passive constrained layer damping to cover the relatively high frequency range (>200 Hz), reactive distributed vibration absorber) to cover the medium frequency range (75 to 250 Hz), and active control for controlling low frequencies (<200 Hz). The device was applied to control noise transmission through a panel mounted in a transmission loss test facility. Experimental results are presented for the bare panel, and combinations of passive treatment, reactive treatment, and active control. Results indicate that three RAP devices were able to increase the overall broadband (15-1000 Hz) transmission loss by 9.4 dB. These three devices added a total of 285 grams to the panel mass of 6.0 kg, or approximately 5%, not including control electronics.
Code of Federal Regulations, 2010 CFR
2010-07-01
... system and add-on control device operating limits during the performance test? 63.3546 Section 63.3546... device or system of multiple capture devices. The average duct static pressure is the maximum operating... Add-on Controls Option § 63.3546 How do I establish the emission capture system and add-on control...
Code of Federal Regulations, 2011 CFR
2011-07-01
... system and add-on control device operating limits during the performance test? 63.3546 Section 63.3546... device or system of multiple capture devices. The average duct static pressure is the maximum operating... Add-on Controls Option § 63.3546 How do I establish the emission capture system and add-on control...
Code of Federal Regulations, 2010 CFR
2010-07-01
... systems or add-on control devices which you choose not to take into account when demonstrating compliance... system or add-on control device which is not taken into account when demonstrating compliance with the....3169 What are the requirements for a capture system or add-on control device which is not taken into...
Code of Federal Regulations, 2010 CFR
2010-07-01
... control device which is not taken into account when demonstrating compliance with the applicable emission limitations? You may have capture systems or add-on control devices which you choose not to take into account... system or add-on control device which is not taken into account when demonstrating compliance with the...
Wearable wireless User Interface Cursor-Controller (UIC-C).
Marjanovic, Nicholas; Kerr, Kevin; Aranda, Ricardo; Hickey, Richard; Esmailbeigi, Hananeh
2017-07-01
Controlling a computer or a smartphone's cursor allows the user to access a world full of information. For millions of people with limited upper extremities motor function, controlling the cursor becomes profoundly difficult. Our team has developed the User Interface Cursor-Controller (UIC-C) to assist the impaired individuals in regaining control over the cursor. The UIC-C is a hands-free device that utilizes the tongue muscle to control the cursor movements. The entire device is housed inside a subject specific retainer. The user maneuvers the cursor by manipulating a joystick imbedded inside the retainer via their tongue. The joystick movement commands are sent to an electronic device via a Bluetooth connection. The device is readily recognizable as a cursor controller by any Bluetooth enabled electronic device. The device testing results have shown that the time it takes the user to control the cursor accurately via the UIC-C is about three times longer than a standard computer mouse controlled via the hand. The device does not require any permanent modifications to the body; therefore, it could be used during the period of acute rehabilitation of the hands. With the development of modern smart homes, and enhancement electronics controlled by the computer, UIC-C could be integrated into a system that enables individuals with permanent impairment, the ability to control the cursor. In conclusion, the UIC-C device is designed with the goal of allowing the user to accurately control a cursor during the periods of either acute or permanent upper extremities impairment.
Advanced methods for controlling untethered magnetic devices using rotating magnetic fields
NASA Astrophysics Data System (ADS)
Mahoney, Arthur W., Jr.
This dissertation presents results documenting advancements on the control of untethered magnetic devices, such as magnetic "microrobots" and magnetically actuated capsule endoscopes, motivated by problems in minimally invasive medicine. This dissertation focuses on applying rotating magnetic fields for magnetic manipulation. The contributions include advancements in the way that helical microswimmers (devices that mimic the propulsion of bacterial flagella) are controlled in the presence of gravitational forces, advancements in ways that groups of untethered magnetic devices can be differentiated and semi-independently controlled, advancements in the way that untethered magnetic device can be controlled with a single rotating permanent magnet, and an improved understanding in the nature of the magnetic force applied to an untethered device by a rotating magnet.
Photovoltaic Powering And Control System For Electrochromic Windows
Schulz, Stephen C.; Michalski, Lech A.; Volltrauer, Hermann N.; Van Dine, John E.
2000-04-25
A sealed insulated glass unit is provided with an electrochromic device for modulating light passing through the unit. The electrochromic device is controlled from outside the unit by a remote control electrically unconnected to the device. Circuitry within the unit may be magnetically controlled from outside. The electrochromic device is powered by a photovoltaic cells. The photovoltaic cells may be positioned so that at least a part of the light incident on the cell passes through the electrochromic device, providing a form of feedback control. A variable resistance placed in parallel with the electrochromic element is used to control the response of the electrochromic element to changes in output of the photovoltaic cell.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-15
... control by other users with a similar medical device. Exposure to non-ionizing radiation Wireless... Administration (FDA) is classifying the wireless air-conduction hearing aid into class II (special controls). The Agency is classifying the device into class II (special controls) in order to provide a reasonable...
40 CFR 63.1283 - Inspection and monitoring requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... the following types of control devices: (i) Except for control devices for small glycol dehydration... used as the primary fuel; (ii) Except for control devices for small glycol dehydration units, a boiler...
40 CFR 63.1283 - Inspection and monitoring requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... the following types of control devices: (i) Except for control devices for small glycol dehydration... used as the primary fuel; (ii) Except for control devices for small glycol dehydration units, a boiler...
A device for controlled jet injection of large volumes of liquid.
Mckeage, James W; Ruddy, Bryan P; Nielsen, Poul M F; Taberner, Andrew J
2016-08-01
We present a needle-free jet injection device controllably actuated by a voice coil and capable of injecting up to 1.3 mL. This device is used to perform jet injections of ~900 μL into porcine tissue. This is the first time that delivery of such a large volume has been reported using an electronically controllable device. The controllability of this device is demonstrated with a series of ejections where the desired volume is ejected to within 1 % during an injection at a predetermined jet velocity.
Electronic system for high power load control. [solar arrays
NASA Technical Reports Server (NTRS)
Miller, E. L. (Inventor)
1980-01-01
Parallel current paths are divided into two groups, with control devices in the current paths of one group each having a current limiting resistor, and the control devices in the other group each having no limiting resistor, so that when the control devices of the second group are turned fully on, a short circuit is achieved by the arrangement of parallel current paths. Separate but coordinated control signals are provided to turn on the control devices of the first group and increase their conduction toward saturation as a function of control input, and when fully on, or shortly before, to turn on the control devices of the second group and increase their conduction toward saturation as a function of the control input as that input continues to increase. Electronic means may be used to generate signals. The system may be used for 1-V characteristic measurements of solar arrays as well as for other load control purposes.
A device for automatic photoelectric control of the analytical gap for emission spectrographs
Dietrich, John A.; Cooley, Elmo F.; Curry, Kenneth J.
1977-01-01
A photoelectric device has been built that automatically controls the analytical gap between electrodes during excitation period. The control device allows for precise control of the analytical gap during the arcing process of samples, resulting in better precision of analysis.
2017-12-20
The Food and Drug Administration (FDA or we) is classifying the image processing device for estimation of external blood loss into class II (special controls). The special controls that apply to the device type are identified in this order and will be part of the codified language for the image processing device for estimation of external blood loss' classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., fans and other such devices allowed in Government-controlled facilities? 102-74.190 Section 102-74.190... § 102-74.190 Are portable heaters, fans and other such devices allowed in Government-controlled facilities? Federal agencies are prohibited from operating portable heaters, fans, and other such devices in...
Instruments speak global language
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nudo, L.
1993-07-01
If all goes as planned, companies that use instruments for measurement and control will get more complete, reliable and repeatable information about their processes with advanced digital devices that speak a global language. That language, in technical terms, is known as international fieldbus. But it's not much different from English's role as the international language of business. Companies that use a remote measurement device for environmental applications, such as pH control and fugitive emissions control, are candidates for fieldbus devices, which are much faster and measure more process variables than their counterpart analog devices. With the advent of a globalmore » fieldbus, users will see digital valves, solenoids and multivariable transmitters. Fieldbus technology redefines the roles of the control system and field devices. The control system still serves as a central clearinghouse, but field devices will handle more control and reporting functions and generate data that can be used for trending and preventive maintenance.« less
Network device interface for digitally interfacing data channels to a controller a via network
NASA Technical Reports Server (NTRS)
Konz, Daniel W. (Inventor); Ellerbrock, Philip J. (Inventor); Grant, Robert L. (Inventor); Winkelmann, Joseph P. (Inventor)
2006-01-01
The present invention provides a network device interface and method for digitally connecting a plurality of data channels to a controller using a network bus. The network device interface interprets commands and data received from the controller and polls the data channels in accordance with these commands. Specifically, the network device interface receives digital commands and data from the controller, and based on these commands and data, communicates with the data channels to either retrieve data in the case of a sensor or send data to activate an actuator. In one embodiment, the bus controller transmits messages to the network device interface containing a plurality of bits having a value defined by a transition between first and second states in the bits. The network device interface determines timing of the data sequence of the message and uses the determined timing to communicate with the bus controller.
Network device interface for digitally interfacing data channels to a controller via a network
NASA Technical Reports Server (NTRS)
Ellerbrock, Philip J. (Inventor); Winkelmann, Joseph P. (Inventor); Grant, Robert L. (Inventor); Konz, Daniel W. (Inventor)
2006-01-01
The present invention provides a network device interface and method for digitally connecting a plurality of data channels, such as sensors, actuators, and subsystems, to a controller using a network bus. The network device interface interprets commands and data received from the controller and polls the data channels in accordance with these commands. Specifically, the network device interface receives digital commands and data from the controller, and based on these commands and data, communicates with the data channels to either retrieve data in the case of a sensor or send data to activate an actuator. Data retrieved from the sensor is then converted by the network device interface into digital signals and transmitted back to the controller. In one advantageous embodiment, the network device interface is a state machine, such as an ASIC, that operates independent of a processor in communicating with the bus controller and data channels.
Brain-controlled body movement assistance devices and methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leuthardt, Eric C.; Love, Lonnie J.; Coker, Rob
Methods, devices, systems, and apparatus, including computer programs encoded on a computer storage medium, for brain-controlled body movement assistance devices. In one aspect, a device includes a brain-controlled body movement assistance device with a brain-computer interface (BCI) component adapted to be mounted to a user, a body movement assistance component operably connected to the BCI component and adapted to be worn by the user, and a feedback mechanism provided in connection with at least one of the BCI component and the body movement assistance component, the feedback mechanism being configured to output information relating to a usage session of themore » brain-controlled body movement assistance device.« less
Light use study for vertical channelization devices
DOT National Transportation Integrated Search
2003-05-01
Although the Manual on Uniform Traffic Control Devices (MUTCD) does not require the use of warning lights on channelization devices, the Arizona Department of Transportation (ADOT) has historically required their use on all traffic control devices us...
14 CFR 25.697 - Lift and drag devices, controls.
Code of Federal Regulations, 2013 CFR
2013-01-01
... conditions of airspeed, engine power, and airplane attitude. (d) The lift device control must be designed to... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Lift and drag devices, controls. 25.697... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25...
40 CFR 63.11516 - What are my standards and management practices?
Code of Federal Regulations, 2013 CFR
2013-07-01
... capture emissions and vent them to a filtration control device. You must operate the filtration control... requirement by maintaining a record of the manufacturer's specifications for the filtration control devices... to emit MFHAP. (1) You must capture emissions and vent them to a filtration control device. You must...
40 CFR 63.1413 - Compliance demonstration procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... or operators are required to conduct a design evaluation for a small control device. An owner or... for small control devices shall be set based on the design evaluation required by paragraph (a)(3) of... efficiency for a control device or control technology, a design evaluation shall address the composition and...
25 CFR 226.36 - Control devices.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 1 2014-04-01 2014-04-01 false Control devices. 226.36 Section 226.36 Indians BUREAU OF... AND GAS MINING Requirements of Lessees § 226.36 Control devices. In drilling operations in fields... operations to maintain proper control of subsurface strata. [55 FR 33116, Aug. 14, 1990] ...
25 CFR 226.36 - Control devices.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 25 Indians 1 2010-04-01 2010-04-01 false Control devices. 226.36 Section 226.36 Indians BUREAU OF... AND GAS MINING Requirements of Lessees § 226.36 Control devices. In drilling operations in fields... operations to maintain proper control of subsurface strata. [55 FR 33116, Aug. 14, 1990] ...
25 CFR 226.36 - Control devices.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 25 Indians 1 2011-04-01 2011-04-01 false Control devices. 226.36 Section 226.36 Indians BUREAU OF... AND GAS MINING Requirements of Lessees § 226.36 Control devices. In drilling operations in fields... operations to maintain proper control of subsurface strata. [55 FR 33116, Aug. 14, 1990] ...
78 FR 5327 - Medical Devices; Ophthalmic Devices; Classification of the Scleral Plug
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-25
... Agency) is proposing to classify the scleral plug into class II (special controls), and proposing to... controls needed to provide reasonable assurance of their safety and effectiveness. The three categories of devices are class I (general controls), class II (special controls), and class III (premarket approval...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berland, Brian Spencer; Lanning, Bruce Roy; Stowell, Jr., Michael Wayne
This disclosure describes system and methods for creating an autonomous electrochromic assembly, and systems and methods for use of the autonomous electrochromic assembly in combination with a window. Embodiments described herein include an electrochromic assembly that has an electrochromic device, an energy storage device, an energy collection device, and an electrochromic controller device. These devices may be combined into a unitary electrochromic insert assembly. The electrochromic assembly may have the capability of generating power sufficient to operate and control an electrochromic device. This control may occur through the application of a voltage to an electrochromic device to change its opacitymore » state. The electrochromic assembly may be used in combination with a window.« less
2017-10-20
The Food and Drug Administration (FDA or we) is classifying the device to detect and identify microbial pathogen nucleic acids in cerebrospinal fluid into class II (special controls). The special controls that will apply to the device type are identified in this order and will be part of the codified language for the device to detect and identify microbial pathogen nucleic acids in cerebrospinal fluid’s classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.
40 CFR 65.146 - Nonflare control devices used for equipment leaks only.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) AIR PROGRAMS (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas System or a Process § 65.146 Nonflare control devices used for equipment leaks only...
32 CFR 636.21 - Obedience to official traffic control devices.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 32 National Defense 4 2014-07-01 2013-07-01 true Obedience to official traffic control devices... INSTALLATIONS) Fort Stewart, Georgia § 636.21 Obedience to official traffic control devices. (a) All drivers... placed by proper authority. ...
32 CFR 636.21 - Obedience to official traffic control devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 32 National Defense 4 2010-07-01 2010-07-01 true Obedience to official traffic control devices... INSTALLATIONS) Fort Stewart, Georgia § 636.21 Obedience to official traffic control devices. (a) All drivers... placed by proper authority. ...
32 CFR 636.21 - Obedience to official traffic control devices.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 32 National Defense 4 2013-07-01 2013-07-01 false Obedience to official traffic control devices... INSTALLATIONS) Fort Stewart, Georgia § 636.21 Obedience to official traffic control devices. (a) All drivers... placed by proper authority. ...
32 CFR 636.21 - Obedience to official traffic control devices.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 32 National Defense 4 2012-07-01 2011-07-01 true Obedience to official traffic control devices... INSTALLATIONS) Fort Stewart, Georgia § 636.21 Obedience to official traffic control devices. (a) All drivers... placed by proper authority. ...
32 CFR 636.21 - Obedience to official traffic control devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 32 National Defense 4 2011-07-01 2011-07-01 false Obedience to official traffic control devices... INSTALLATIONS) Fort Stewart, Georgia § 636.21 Obedience to official traffic control devices. (a) All drivers... placed by proper authority. ...
Electronic firing systems and methods for firing a device
Frickey, Steven J [Boise, ID; Svoboda, John M [Idaho Falls, ID
2012-04-24
An electronic firing system comprising a control system, a charging system, an electrical energy storage device, a shock tube firing circuit, a shock tube connector, a blasting cap firing circuit, and a blasting cap connector. The control system controls the charging system, which charges the electrical energy storage device. The control system also controls the shock tube firing circuit and the blasting cap firing circuit. When desired, the control system signals the shock tube firing circuit or blasting cap firing circuit to electrically connect the electrical energy storage device to the shock tube connector or the blasting cap connector respectively.
Code of Federal Regulations, 2010 CFR
2010-07-01
... device operating limits during the performance test? 63.3167 Section 63.3167 Protection of Environment... Limitations § 63.3167 How do I establish the add-on control device operating limits during the performance.... (a) Thermal oxidizers. If your add-on control device is a thermal oxidizer, establish the operating...
Imitative Robotic Control: The Puppet Master
2014-07-09
puppet style control device and the lessons learned while implementing such a device. 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: 17...mission to be completed in a quick, accurate and efficient manner. This paper outlines the potential features of a puppet style control device and the...lessons learned while implementing such a device. INTRODUCTION As ground robotics moves towards autonomous and semi- autonomous operations, the
Xu, Shi-Zhou; Wang, Chun-Jie; Lin, Fang-Li; Li, Shi-Xiang
2017-10-31
The multi-device open-circuit fault is a common fault of ANPC (Active Neutral-Point Clamped) three-level inverter and effect the operation stability of the whole system. To improve the operation stability, this paper summarized the main solutions currently firstly and analyzed all the possible states of multi-device open-circuit fault. Secondly, an order-reduction optimal control strategy was proposed under multi-device open-circuit fault to realize fault-tolerant control based on the topology and control requirement of ANPC three-level inverter and operation stability. This control strategy can solve the faults with different operation states, and can works in order-reduction state under specific open-circuit faults with specific combined devices, which sacrifices the control quality to obtain the stability priority control. Finally, the simulation and experiment proved the effectiveness of the proposed strategy.
Kim, Wonjae; Riikonen, Juha; Li, Changfeng; Chen, Ya; Lipsanen, Harri
2013-10-04
Using single-layer CVD graphene, a complementary field effect transistor (FET) device is fabricated on the top of separated back-gates. The local back-gate control of the transistors, which operate with low bias at room temperature, enables highly tunable device characteristics due to separate control over electrostatic doping of the channels. Local back-gating allows control of the doping level independently of the supply voltage, which enables device operation with very low VDD. Controllable characteristics also allow the compensation of variation in the unintentional doping typically observed in CVD graphene. Moreover, both p-n and n-p configurations of FETs can be achieved by electrostatic doping using the local back-gate. Therefore, the device operation can also be switched from inverter to voltage controlled resistor, opening new possibilities in using graphene in logic circuitry.
2016-07-13
The Food and Drug Administration (FDA) is classifying the metallic biliary stent system for benign strictures into class II (special controls). The special controls that will apply to the device are identified in this order and will be part of the codified language for the metallic biliary stent system for benign strictures' classification. The Agency is classifying the device into class II (special controls) in order to provide a reasonable assurance of safety and effectiveness of the device.
40 CFR 65.151 - Condensers used as control devices.
Code of Federal Regulations, 2014 CFR
2014-07-01
... the design evaluation for storage vessels and low-throughput transfer rack controls. As provided in... control device on a Group 1 process vent or a high-throughput transfer rack with a condenser used as a... 40 Protection of Environment 16 2014-07-01 2014-07-01 false Condensers used as control devices. 65...
40 CFR 65.151 - Condensers used as control devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... the design evaluation for storage vessels and low-throughput transfer rack controls. As provided in... control device on a Group 1 process vent or a high-throughput transfer rack with a condenser used as a... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Condensers used as control devices. 65...
40 CFR 65.151 - Condensers used as control devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... the design evaluation for storage vessels and low-throughput transfer rack controls. As provided in... control device on a Group 1 process vent or a high-throughput transfer rack with a condenser used as a... 40 Protection of Environment 15 2011-07-01 2011-07-01 false Condensers used as control devices. 65...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-07
... intended for non-invasive aesthetic use will need to address the issues covered in the special controls... intended for non-invasive aesthetic use. (b) Classification. Class II (special controls). The special... into class II (special controls). The special control that will apply to the device is the guidance...
Re-Active Passive devices for control of noise transmission through a panel
NASA Astrophysics Data System (ADS)
Carneal, James P.; Giovanardi, Marco; Fuller, Chris R.; Palumbo, Dan
2008-01-01
Re-Active Passive devices have been developed to control low-frequency (<1000 Hz) noise transmission through a panel. These devices use a combination of active, re-active, and passive technologies packaged into a single unit to control a broad frequency range utilizing the strength of each technology over its best suited frequency range. The Re-Active Passive device uses passive constrained layer damping to cover relatively high-frequency range (>150 Hz), reactive distributed vibration absorber to cover the medium-frequency range (50-200 Hz), and active control for controlling low frequencies (<150 Hz). The actuator was applied to control noise transmission through a panel mounted in the Transmission Loss Test Facility at Virginia Tech. Experimental results are presented for the bare panel, and combinations of passive treatment, reactive treatment, and active control. Results indicate that three Re-Active Passive devices were able to increase the overall broadband (15-1000 Hz) transmission loss by 9.4 dB. These three devices added a total of 285 g to the panel mass of 6.0 kg, or approximately 5%, not including control electronics.
Team Electronic Gameplay Combining Different Means of Control
NASA Technical Reports Server (NTRS)
Palsson, Olafur S. (Inventor); Pope, Alan T. (Inventor)
2014-01-01
Disclosed are methods and apparatuses provided for modifying the effect of an operator controlled input device on an interactive device to encourage the self-regulation of at least one physiological activity by a person different than the operator. The interactive device comprises a display area which depicts images and apparatus for receiving at least one input from the operator controlled input device to thus permit the operator to control and interact with at least some of the depicted images. One effect modification comprises measurement of the physiological activity of a person different from the operator, while modifying the ability of the operator to control and interact with at least some of the depicted images by modifying the input from the operator controlled input device in response to changes in the measured physiological signal.
Integrated Real-Time Control and Imaging System for Microbiorobotics and Nanobiostructures
2016-01-11
kit with a control board and ALP 4.1 basic controller suite. The digital micromirror device is the highest resolution 16:9 aspect ratio system. This...in Figure 1, consisted of the following: (1) digital micromirror device (DMD) and controller, (2) an inverted epifluorescence microscope with a flat...accompanying control board and ALP 4.1 basic controller suite. The digital micromirror device is currently the highest commercially available
Code of Federal Regulations, 2010 CFR
2010-07-01
... equivalent control device. (2) Route the air-perchloroethylene gas-vapor stream contained within each dry... contained within each dry cleaning machine through a refrigerated condenser or an equivalent control device... cleaning machine drum through a carbon adsorber or equivalent control device immediately before or as the...
Code of Federal Regulations, 2014 CFR
2014-07-01
... equivalent control device. (2) Route the air-perchloroethylene gas-vapor stream contained within each dry... contained within each dry cleaning machine through a refrigerated condenser or an equivalent control device... cleaning machine drum through a carbon adsorber or equivalent control device immediately before or as the...
Apparatus and method to inject a reductant into an exhaust gas feedstream
Viola, Michael B [Macomb Township, MI
2009-09-22
An exhaust aftertreatment system for an internal combustion engine is provided including an apparatus and method to inject a reductant into the exhaust gas feedstream. Included is a fuel metering device adapted to inject reductant into the exhaust gas feedstream and a controllable pressure regulating device. A control module is operatively connected to the reductant metering device and the controllable pressure regulating device, and, adapted to effect flow of reductant into the exhaust gas feedstream over a controllable flow range.
NASA Astrophysics Data System (ADS)
Ozbulut, Osman E.; Hurlebaus, Stefan
2011-11-01
This paper proposes a re-centering variable friction device (RVFD) for control of civil structures subjected to near-field earthquakes. The proposed hybrid device has two sub-components. The first sub-component of this hybrid device consists of shape memory alloy (SMA) wires that exhibit a unique hysteretic behavior and full recovery following post-transformation deformations. The second sub-component of the hybrid device consists of variable friction damper (VFD) that can be intelligently controlled for adaptive semi-active behavior via modulation of its voltage level. In general, installed SMA devices have the ability to re-center structures at the end of the motion and VFDs can increase the energy dissipation capacity of structures. The full realization of these devices into a singular, hybrid form which complements the performance of each device is investigated in this study. A neuro-fuzzy model is used to capture rate- and temperature-dependent nonlinear behavior of the SMA components of the hybrid device. An optimal fuzzy logic controller (FLC) is developed to modulate voltage level of VFDs for favorable performance in a RVFD hybrid application. To obtain optimal controllers for concurrent mitigation of displacement and acceleration responses, tuning of governing fuzzy rules is conducted by a multi-objective heuristic optimization. Then, numerical simulation of a multi-story building is conducted to evaluate the performance of the hybrid device. Results show that a re-centering variable friction device modulated with a fuzzy logic control strategy can effectively reduce structural deformations without increasing acceleration response during near-field earthquakes.
Power throttling of collections of computing elements
Bellofatto, Ralph E [Ridgefield, CT; Coteus, Paul W [Yorktown Heights, NY; Crumley, Paul G [Yorktown Heights, NY; Gara, Alan G [Mount Kidsco, NY; Giampapa, Mark E [Irvington, NY; Gooding,; Thomas, M [Rochester, MN; Haring, Rudolf A [Cortlandt Manor, NY; Megerian, Mark G [Rochester, MN; Ohmacht, Martin [Yorktown Heights, NY; Reed, Don D [Mantorville, MN; Swetz, Richard A [Mahopac, NY; Takken, Todd [Brewster, NY
2011-08-16
An apparatus and method for controlling power usage in a computer includes a plurality of computers communicating with a local control device, and a power source supplying power to the local control device and the computer. A plurality of sensors communicate with the computer for ascertaining power usage of the computer, and a system control device communicates with the computer for controlling power usage of the computer.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holzrichter, John F
2015-05-05
An implanted stimulation device or air control device are activated by an external radar-like sensor for controlling apnea. The radar-like sensor senses the closure of the air flow cavity, and associated control circuitry signals (1) a stimulator to cause muscles to open the air passage way that is closing or closed or (2) an air control device to open the air passage way that is closing or closed.
Network device interface for digitally interfacing data channels to a controller via a network
NASA Technical Reports Server (NTRS)
Ellerbrock, Philip J. (Inventor); Grant, Robert L. (Inventor); Konz, Daniel W. (Inventor); Winkelmann, Joseph P. (Inventor)
2005-01-01
The present invention provides a network device interface and method for digitally connecting a plurality of data channels, such as sensors, actuators, and subsystems, to a controller using a network bus. The network device interface interprets commands and data received from the controller and polls the data channels in accordance with these commands. Specifically, the network device interface receives digital commands and data from the controller, and based on these commands and data, communicates with the data channels to either retrieve data in the case of a sensor or send data to activate an actuator. Data retrieved from the sensor is then converted by the network device interface into digital signals and transmitted back to the controller. In one advantageous embodiment, the network device interface uses a specialized protocol for communicating across the network bus that uses a low-level instruction set and has low overhead for data communication.
Network device interface for digitally interfacing data channels to a controller via a network
NASA Technical Reports Server (NTRS)
Ellerbrock, Philip J. (Inventor); Konz, Daniel W. (Inventor); Winkelmann, Joseph P. (Inventor); Grant, Robert L. (Inventor)
2004-01-01
The present invention provides a network device interface and method for digitally connecting a plurality of data channels, such as sensors, actuators, and subsystems, to a controller using a network bus. The network device interface interprets commands and data received from the controller and polls the data channels in accordance with these commands. Specifically, the network device interface receives digital commands and data from the controller, and based on these commands and data, communicates with the data channels to either retrieve data in the case of a sensor or send data to activate an actuator. Data retrieved from the sensor is then converted by the network device interface into digital signals and transmitted back to the controller. In one advantageous embodiment, the network device interface uses a specialized protocol for communicating across the network bus that uses a low-level instruction set and has low overhead for data communication.
Network device interface for digitally interfacing data channels to a controller via a network
NASA Technical Reports Server (NTRS)
Konz, Daniel W. (Inventor); Ellerbrock, Philip J. (Inventor); Grant, Robert L. (Inventor); Winkelmann, Joseph P. (Inventor)
2006-01-01
The present invention provides a network device interface and method for digitally connecting a plurality of data channels, such as sensors, actuators, and subsystems, to a controller using a network bus. The network device interface interprets commands and data received from the controller and polls the data channels in accordance with these commands. Specifically, the network device interface receives digital commands and data from the controller, and based on these commands and data, communicates with the data channels to either retrieve data in the case of a sensor or send data to activate an actuator. Data retrieved from the sensor is then converted into digital signals and transmitted back to the controller. In one embodiment, the bus controller sends commands and data a defined bit rate, and the network device interface senses this bit rate and sends data back to the bus controller using the defined bit rate.
Variable control of neutron albedo in toroidal fusion devices
Jassby, D.L.; Micklich, B.J.
1983-06-01
This invention pertains to methods of controlling in the steady state, neutron albedo in toroidal fusion devices, and in particular, to methods of controlling the flux and energy distribution of collided neutrons which are incident on an outboard wall of a toroidal fusion device.
Code of Federal Regulations, 2011 CFR
2011-10-01
... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.747 Forestall. As applied to an automatic train stop or train control device, to prevent an automatic brake application by operation of an acknowledging device or by manual control of the speed of the train. ...
Code of Federal Regulations, 2010 CFR
2010-10-01
... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.747 Forestall. As applied to an automatic train stop or train control device, to prevent an automatic brake application by operation of an acknowledging device or by manual control of the speed of the train. ...
Emulating Industrial Control System Field Devices Using Gumstix Technology
2012-06-01
EMULATING INDUSTRIAL CONTROL SYSTEM FIELD DEVICES USING GUMSTIX TECHNOLOGY THESIS Dustin J...APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED. The views expressed in this thesis are those of the...EMULATING INDUSTRIAL CONTROL SYSTEM FIELD DEVICES USING GUMSTIX TECHNOLOGY THESIS Presented to the Faculty Department of
40 CFR 60.2151 - By what date must I conduct the annual air pollution control device inspection?
Code of Federal Regulations, 2013 CFR
2013-07-01
... air pollution control device inspection? 60.2151 Section 60.2151 Protection of Environment... Compliance Requirements § 60.2151 By what date must I conduct the annual air pollution control device inspection? On an annual basis (no more than 12 months following the previous annual air pollution control...
40 CFR 60.2151 - By what date must I conduct the annual air pollution control device inspection?
Code of Federal Regulations, 2014 CFR
2014-07-01
... air pollution control device inspection? 60.2151 Section 60.2151 Protection of Environment... Compliance Requirements § 60.2151 By what date must I conduct the annual air pollution control device inspection? On an annual basis (no more than 12 months following the previous annual air pollution control...
14 CFR 29.687 - Spring devices.
Code of Federal Regulations, 2013 CFR
2013-01-01
... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Design and Construction Control Systems § 29.687 Spring devices. (a) Each control system spring device whose failure could cause flutter or other unsafe characteristics...
14 CFR 27.687 - Spring devices.
Code of Federal Regulations, 2013 CFR
2013-01-01
... STANDARDS: NORMAL CATEGORY ROTORCRAFT Design and Construction Control Systems § 27.687 Spring devices. (a) Each control system spring device whose failure could cause flutter or other unsafe characteristics...
Comparison of Driver Yielding for Three Rapid-flashing Patterns Used with Pedestrian Crossing Signs
DOT National Transportation Integrated Search
2015-05-01
Flashing traffic control devices can help draw drivers attention to the traffic control device and to the area around the device. An example of a device that has resulted in significant improvements in increasing driver yielding to crossing pedest...
Determining Desirable Cursor Control Device Characteristics for NASA Exploration Missions
NASA Technical Reports Server (NTRS)
Sandor, Aniko; Holden, Kritina L.
2007-01-01
A test battery was developed for cursor control device evaluation: four tasks were taken from ISO 9241-9, and three from previous studies conducted at NASA. The tasks focused on basic movements such as pointing, clicking, and dragging. Four cursor control devices were evaluated with and without Extravehicular Activity (EVA) gloves to identify desirable cursor control device characteristics for NASA missions: 1) the Kensington Expert Mouse, 2) the Hulapoint mouse, 3) the Logitech Marble Mouse, and 4) the Honeywell trackball. Results showed that: 1) the test battery is an efficient tool for differentiating among input devices, 2) gloved operations were about 1 second slower and had at least 15% more errors; 3) devices used with gloves have to be larger, and should allow good hand positioning to counteract the lack of tactile feedback, 4) none of the devices, as designed, were ideal for operation with EVA gloves.
Closed-loop motor control using high-speed fiber optics
NASA Technical Reports Server (NTRS)
Dawson, Reginald (Inventor); Rodriquiz, Dagobert (Inventor)
1991-01-01
A closed-loop control system for controlling the operation of one or more servo motors or other controllable devices is described. The system employs a fiber optics link immune to electromagnetic interference, for transmission of control signals from a controller or controllers at a remote station to the power electronics located in proximity to the motors or other devices at the local station. At the remote station the electrical control signals are time-multiplexed, converted to a formatted serial bit stream, and converted to light signals for transmission over a single fiber of the fiber optics link. At the local station, the received optical signals are reconstructed as electrical control signals for the controlled motors or other devices. At the local station, an encoder sensor linked to the driven device generates encoded feedback signals which provide information as to a condition of the controlled device. The encoded signals are placed in a formatted serial bit stream, multiplexed, and transmitted as optical signals over a second fiber of the fiber optic link which closes the control loop of the closed-loop motor controller. The encoded optical signals received at the remote station are demultiplexed, reconstructed and coupled to the controller(s) as electrical feedback signals.
Mauser, Stanislas; Burgert, Oliver
2014-01-01
There are several intra-operative use cases which require the surgeon to interact with medical devices. We used the Leap Motion Controller as input device and implemented two use-cases: 2D-Interaction (e.g. advancing EPR data) and selection of a value (e.g. room illumination brightness). The gesture detection was successful and we mapped its output to several devices and systems.
2018-01-02
The Food and Drug Administration (FDA or we) is classifying the whole slide imaging system into class II (special controls). The special controls that apply to the device type are identified in this order and will be part of the codified language for the whole slide imaging system's classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.
2017-10-18
The Food and Drug Administration (FDA or we) is classifying the organophosphate test system into class II (special controls). The special controls that apply to the device type are identified in this order and will be part of the codified language for the organophosphate test system's classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.
DEVICE FOR CONTROL OF OXYGEN PARTIAL PRESSURE
Bradner, H.; Gordon, H.S.
1957-12-24
A device is described that can sense changes in oxygen partial pressure and cause a corresponding mechanical displacement sufficient to actuate meters, valves and similar devices. A piston and cylinder arrangement contains a charge of crystalline metal chelate pellets which have the peculiar property of responding to variations in the oxygen content of the ambient atmosphere by undergoing a change in dimension. A lever system amplifies the relative displacement of the piston in the cylinder, and actuates the controlled valving device. This partial pressure oxygen sensing device is useful in controlled chemical reactions or in respiratory devices such as the oxygen demand meters for high altitude aircraft.
2018-01-03
The Food and Drug Administration (FDA or we) is classifying the cervical intraepithelial neoplasia (CIN) test system into class II (special controls). The special controls that apply to the device type are identified in this order and will be part of the codified language for the CIN test system's classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.
Accuracy of torque-limiting devices: A comparative evaluation.
Albayrak, Haydar; Gumus, Hasan Onder; Tursun, Funda; Kocaagaoglu, Hasan Huseyin; Kilinc, Halil Ibrahim
2017-01-01
To prevent the loosening of implant screws, clinicians should be aware of the output torque values needed to achieve the desired preload. Accurate torque-control devices are crucial in this regard; however, little information is currently available comparing the accuracy of mechanical with that of electronic torque-control devices. The purpose of this in vitro study was to identify and compare the accuracy of different types of torque-control devices. Devices from 5 different dental implant manufacturers were evaluated, including 2 spring-type (Straumann, Implance) mechanical devices (MTLD), 2 friction-type (Biohorizons, Dyna) MTLDs, and 1 (Megagen) electronic torque-control device (ETLD). For each manufacturer, 5 devices were tested 5 times with a digital torque tester, and the average for each device was calculated and recorded. The percentage of absolute deviations from the target torque values (PERDEV) were calculated and compared by using 1-way ANOVA. A 1-sample t test was used to evaluate the ability of each device to achieve its target torque value within a 95% confidence interval for the true population mean of measured values (α=.05 for all statistical analyses). One-way ANOVAs revealed statistically significant differences among torque-control devices (P<.001). ETLD showed higher PERDEVs (28.33 ±9.53) than MTLDs (P<.05), whereas PERDEVS of friction-type (7.56 ±3.64) and spring-type (10.85 ±4.11) MTLDs did not differ significantly. In addition, devices produced by Megagen had a significantly higher (P<.05) PERDEV (28.33 ±9.53) other devices, whereas no differences were found in devices manufactured by Biohorizons (7.31 ±5.34), Dyna (7.82 ±1.08), Implance (8.43 ±4.77), and Straumann (13.26 ±0.79). However, 1-sample t tests showed none of the torque-control devices evaluated in this study were capable of achieving their target torque values (P<.05). Within the limitations of this in vitro study, MTLDs were shown to be significantly more accurate than ETLDs. However, none of the torque-control devices evaluated were able to meet their target torque values successfully. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Creating a systems engineering approach for the manual on uniform traffic control devices.
DOT National Transportation Integrated Search
2011-03-01
The Manual on Uniform Traffic Control Devices (MUTCD) provides basic principles for use of traffic : control devices (TCD). However, most TCDs are not explicitly required, and the decision to use a given : TCD in a given situation is typically made b...
49 CFR 236.739 - Device, acknowledging.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.739... locomotive equipped with an automatic train stop or train control device, an automatic brake application can be forestalled, or by means of which, on a locomotive equipped with an automatic cab signal device...
14 CFR 29.687 - Spring devices.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Spring devices. 29.687 Section 29.687... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Design and Construction Control Systems § 29.687 Spring devices. (a) Each control system spring device whose failure could cause flutter or other unsafe characteristics...
14 CFR 29.687 - Spring devices.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Spring devices. 29.687 Section 29.687... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Design and Construction Control Systems § 29.687 Spring devices. (a) Each control system spring device whose failure could cause flutter or other unsafe characteristics...
14 CFR 29.687 - Spring devices.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Spring devices. 29.687 Section 29.687... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Design and Construction Control Systems § 29.687 Spring devices. (a) Each control system spring device whose failure could cause flutter or other unsafe characteristics...
14 CFR 27.687 - Spring devices.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Spring devices. 27.687 Section 27.687... STANDARDS: NORMAL CATEGORY ROTORCRAFT Design and Construction Control Systems § 27.687 Spring devices. (a) Each control system spring device whose failure could cause flutter or other unsafe characteristics...
14 CFR 27.687 - Spring devices.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Spring devices. 27.687 Section 27.687... STANDARDS: NORMAL CATEGORY ROTORCRAFT Design and Construction Control Systems § 27.687 Spring devices. (a) Each control system spring device whose failure could cause flutter or other unsafe characteristics...
14 CFR 27.687 - Spring devices.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Spring devices. 27.687 Section 27.687... STANDARDS: NORMAL CATEGORY ROTORCRAFT Design and Construction Control Systems § 27.687 Spring devices. (a) Each control system spring device whose failure could cause flutter or other unsafe characteristics...
14 CFR 29.687 - Spring devices.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Spring devices. 29.687 Section 29.687... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Design and Construction Control Systems § 29.687 Spring devices. (a) Each control system spring device whose failure could cause flutter or other unsafe characteristics...
14 CFR 27.687 - Spring devices.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Spring devices. 27.687 Section 27.687... STANDARDS: NORMAL CATEGORY ROTORCRAFT Design and Construction Control Systems § 27.687 Spring devices. (a) Each control system spring device whose failure could cause flutter or other unsafe characteristics...
2017-10-24
The Food and Drug Administration (FDA or we) is classifying the device to detect and measure non-microbial analyte(s) in human clinical specimens to aid in assessment of patients with suspected sepsis into class II (special controls). The special controls that apply to the device type are identified in this order and will be part of the codified language for the device to detect and measure non-microbial analyte(s) in human clinical specimens to aid in assessment of patients with suspected sepsis's classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.
14 CFR 23.687 - Spring devices.
Code of Federal Regulations, 2014 CFR
2014-01-01
... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.687 Spring devices. The reliability of any spring device used in the control system must be...
14 CFR 23.687 - Spring devices.
Code of Federal Regulations, 2012 CFR
2012-01-01
... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.687 Spring devices. The reliability of any spring device used in the control system must be...
14 CFR 23.687 - Spring devices.
Code of Federal Regulations, 2013 CFR
2013-01-01
... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.687 Spring devices. The reliability of any spring device used in the control system must be...
14 CFR 23.687 - Spring devices.
Code of Federal Regulations, 2010 CFR
2010-01-01
... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.687 Spring devices. The reliability of any spring device used in the control system must be...
14 CFR 23.687 - Spring devices.
Code of Federal Regulations, 2011 CFR
2011-01-01
... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.687 Spring devices. The reliability of any spring device used in the control system must be...
Chan, Amy Hai Yan; Stewart, Alistair William; Harrison, Jeff; Black, Peter Nigel; Mitchell, Edwin Arthur; Foster, Juliet Michelle
2017-05-01
To investigate the performance and patient acceptability of an inhaler electronic monitoring device in a real-world childhood asthma population. Children 6 to 15 years presenting with asthma to the hospital emergency department and prescribed inhaled corticosteroids were included. Participants were randomized to receive a device with reminder features enabled or disabled for use with their preventer. Device quality control tests were conducted. Questionnaires on device acceptability, utility and ergonomics were completed at six months. A total of 1306 quality control tests were conducted; 84% passed pre-issue and 87% return testing. The most common failure reason was actuation under-recording. Acceptability scores were high, with higher scores in the reminder than non-reminder group (median, 5 th -95 th percentile: 4.1, 3.1-5.0 versus 3.7, 2.3-4.8; p < 0.001). Most (>90%) rated the device easy to use. Feedback was positive across five themes: device acceptability, ringtone acceptability, suggestions for improvement, effect on medication use, and effect on asthma control. This study investigates electronic monitoring device performance and acceptability in children using quantitative and qualitative measures. Results indicate satisfactory reliability, although failure rates of 13-16% indicate the importance of quality control. Favorable acceptability ratings support the use of these devices in children.
Code of Federal Regulations, 2013 CFR
2013-07-01
... system and add-on control device operating limits during the performance test? 63.4167 Section 63.4167... Emission Rate with Add-on Controls Option § 63.4167 How do I establish the emission capture system and add-on control device operating limits during the performance test? During the performance test required...
40 CFR 63.5767 - What records must I keep?
Code of Federal Regulations, 2011 CFR
2011-07-01
... by an add-on control device (i.e., you are complying with organic HAP content limits, application...-average organic HAP content as determined in § 63.5749. (d) If your facility has an add-on control device... malfunction events; control device performance tests; and continuous monitoring system performance evaluations. ...
40 CFR 63.5767 - What records must I keep?
Code of Federal Regulations, 2010 CFR
2010-07-01
... by an add-on control device (i.e., you are complying with organic HAP content limits, application...-average organic HAP content as determined in § 63.5749. (d) If your facility has an add-on control device... malfunction events; control device performance tests; and continuous monitoring system performance evaluations. ...
40 CFR 265.1088 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Standards: Closed-vent systems and control devices. 265.1088 Section 265.1088 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Containers § 265.1088 Standards: Closed-vent systems and control devices. (a) This section applies to each...
40 CFR 264.1087 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Standards: Closed-vent systems and control devices. 264.1087 Section 264.1087 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY....1087 Standards: Closed-vent systems and control devices. (a) This section applies to each closed-vent...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-02
... design and application of traffic control devices, this Manual should not be considered a substitute for... retroreflectivity of longitudinal pavement markings. The deadline for comments to that docket has passed and the... the proposed revisions regarding maintaining minimum retroreflectivity of longitudinal pavement...
Hall devices improve electric motor efficiency
NASA Technical Reports Server (NTRS)
Haeussermann, W.
1979-01-01
Efficiency of electric motors and generators is reduced by radial magnetic forces created by symmetric fields within device. Forces are sensed and counteracted by Hall devices on excitation or control windings. Hall generators directly measure and provide compensating control of anu asymmetry, eliminating additional measurements needed for calibration feedback control loop.
40 CFR 63.137 - Process wastewater provisions-oil-water separators.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... (2) The control device shall be designed, operated, and inspected in accordance with the requirements... receives, manages, or treats a Group 1 wastewater stream or a residual removed from a Group 1 wastewater... control device. The fixed roof, closed-vent system, and control device shall meet the requirements...
40 CFR 63.137 - Process wastewater provisions-oil-water separators.
Code of Federal Regulations, 2014 CFR
2014-07-01
.... (2) The control device shall be designed, operated, and inspected in accordance with the requirements... receives, manages, or treats a Group 1 wastewater stream or a residual removed from a Group 1 wastewater... control device. The fixed roof, closed-vent system, and control device shall meet the requirements...
40 CFR 63.137 - Process wastewater provisions-oil-water separators.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... (2) The control device shall be designed, operated, and inspected in accordance with the requirements... receives, manages, or treats a Group 1 wastewater stream or a residual removed from a Group 1 wastewater... control device. The fixed roof, closed-vent system, and control device shall meet the requirements...
40 CFR 65.163 - Other records.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Detailed schematics, design specifications of the control device, and piping and instrumentation diagrams... FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas System or a Process § 65... bypass lines that could divert a vent stream away from the control device and to the atmosphere, the...
ERIC Educational Resources Information Center
Schneiderman, Helen, Ed.
1994-01-01
Environmental control units, or ECUs, are devices or systems which allow for alternate access to electronic or electrical devices and those objects, like draperies and doors, which may be adapted for use with electricity. Such devices offer the person with a mobility limitation the opportunity to control his or her environment, thus enhancing the…
Code of Federal Regulations, 2011 CFR
2011-07-01
... covered electric furnaces and other smelting operations with wet air pollution control devices subcategory... Smelting Operations With Wet Air Pollution Control Devices Subcategory § 424.20 Applicability; description of the covered electric furnaces and other smelting operations with wet air pollution control devices...
Code of Federal Regulations, 2010 CFR
2010-07-01
... covered electric furnaces and other smelting operations with wet air pollution control devices subcategory... Smelting Operations With Wet Air Pollution Control Devices Subcategory § 424.20 Applicability; description of the covered electric furnaces and other smelting operations with wet air pollution control devices...
49 CFR 236.501 - Forestalling device and speed control.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Forestalling device and speed control. 236.501... Train Stop, Train Control and Cab Signal Systems Standards § 236.501 Forestalling device and speed... the following features: (1) Low-speed restriction, requiring the train to proceed under slow speed...
49 CFR 236.501 - Forestalling device and speed control.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Forestalling device and speed control. 236.501... Train Stop, Train Control and Cab Signal Systems Standards § 236.501 Forestalling device and speed... the following features: (1) Low-speed restriction, requiring the train to proceed under slow speed...
Code of Federal Regulations, 2012 CFR
2012-07-01
... covered electric furnaces and other smelting operations with wet air pollution control devices subcategory... Smelting Operations With Wet Air Pollution Control Devices Subcategory § 424.20 Applicability; description of the covered electric furnaces and other smelting operations with wet air pollution control devices...
Code of Federal Regulations, 2013 CFR
2013-07-01
... covered electric furnaces and other smelting operations with wet air pollution control devices subcategory... Smelting Operations With Wet Air Pollution Control Devices Subcategory § 424.20 Applicability; description of the covered electric furnaces and other smelting operations with wet air pollution control devices...
Code of Federal Regulations, 2014 CFR
2014-07-01
... covered electric furnaces and other smelting operations with wet air pollution control devices subcategory... Smelting Operations With Wet Air Pollution Control Devices Subcategory § 424.20 Applicability; description of the covered electric furnaces and other smelting operations with wet air pollution control devices...
21 CFR 892.5700 - Remote controlled radionuclide applicator system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Remote controlled radionuclide applicator system. 892.5700 Section 892.5700 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Therapeutic Devices § 892.5700 Remote controlled...
Review of microfluidic cell culture devices for the control of gaseous microenvironments in vitro
NASA Astrophysics Data System (ADS)
Wu, H.-M.; Lee, T.-A.; Ko, P.-L.; Chiang, H.-J.; Peng, C.-C.; Tung, Y.-C.
2018-04-01
Gaseous microenvironments play important roles in various biological activities in vivo. However, it is challenging to precisely control gaseous microenvironments in vitro for cell culture due to the high diffusivity nature of gases. In recent years, microfluidics has paved the way for the development of new types of cell culture devices capable of manipulating cellular microenvironments, and provides a powerful tool for in vitro cell studies. This paper reviews recent developments of microfluidic cell culture devices for the control of gaseous microenvironments, and discusses the advantages and limitations of current devices. We conclude with suggestions for the future development of microfluidic cell culture devices for the control of gaseous microenvironments.
2014-01-23
The Food and Drug Administration (FDA) is classifying John Cunningham Virus (JCV) serological reagents into class II (special controls). The Agency is classifying the device into class II (special controls) in order to provide a reasonable assurance of safety and effectiveness of the device.
49 CFR 220.311 - Railroad operating employees in deadhead status.
Code of Federal Regulations, 2010 CFR
2010-10-01
...) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD COMMUNICATIONS Electronic Devices... controlling locomotive may use an electronic device only if the employee is not using the device in such a way... controlling locomotive must have each electronic device turned off with any earpiece removed from the ear— (1...
Placebo Devices as Effective Control Methods in Acupuncture Clinical Trials: A Systematic Review
Zhang, Claire Shuiqing; Tan, Hsiewe Ying; Zhang, George Shengxi; Zhang, Anthony Lin; Xue, Charlie Changli; Xie, Yi Min
2015-01-01
While the use of acupuncture has been recognised by the World Health Organisation, its efficacy for many of the common clinical conditions is still undergoing validation through randomised controlled trials (RCTs). A credible placebo control for such RCTs to enable meaningful evaluation of its efficacy is to be established. While several non-penetrating acupuncture placebo devices, namely the Streitberger, the Park and the Takakura Devices, have been developed and used in RCTs, their suitability as inert placebo controls needs to be rigorously determined. This article systematically reviews these devices as placebo interventions. Electronic searches were conducted on four English and two Chinese databases from their inceptions to July 2014; hand searches of relevant references were also conducted. RCTs, in English or Chinese language, comparing acupuncture with one of the aforementioned devices as the control intervention on human participants with any clinical condition and evaluating clinically related outcomes were included. Thirty-six studies were included for qualitative analysis while 14 were in the meta-analysis. The meta-analysis does not support the notion of either the Streitberger or the Park Device being inert control interventions while none of the studies involving the Takakura Device was included in the meta-analysis. Sixteen studies reported the occurrence of adverse events, with no significant difference between verum and placebo acupuncture. Author-reported blinding credibility showed that participant blinding was successful in most cases; however, when blinding index was calculated, only one study, which utilised the Park Device, seemed to have an ideal blinding scenario. Although the blinding index could not be calculated for the Takakura Device, it was the only device reported to enable practitioner blinding. There are limitations with each of the placebo devices and more rigorous studies are needed to further evaluate their effects and blinding credibility. PMID:26536619
Fast-regenerable sulfur dioxide adsorbents for diesel engine emission control
Li, Liyu [Richland, WA; King, David L [Richland, WA
2011-03-15
Disclosed herein are sorbents and devices for controlling sulfur oxides emissions as well as systems including such sorbents and devices. Also disclosed are methods for making and using the disclosed sorbents, devices and systems. In one embodiment the disclosed sorbents can be conveniently regenerated, such as under normal exhaust stream from a combustion engine, particularly a diesel engine. Accordingly, also disclosed are combustion vehicles equipped with sulfur dioxide emission control devices.
Chern, Bernard; Siow, Anthony
2005-09-01
To present our initial experience in the use of the Essure permanent birth control device in a predominately Asian population. A retrospective study. Minimally Invasive Surgery Unit, KK Women's and Children's Hospital, Singapore. Eighty women seeking permanent birth control. From 22 June 2001, women who sought sterilisation were counselled with regards to the various options of permanent birth control. Informed consent for hysteroscopic sterilisation was obtained only after the woman met the criteria for Essure permanent birth control. The sterilisation procedure was carried out without the need for general anaesthesia in a day surgery centre using the Essure permanent birth control device. The surgical details and post procedure follow up were analysed. Feasibility and safety of the Essure permanent birth control device in Asians and its non-placement rate. No serious adverse events or complications were encountered in using the Essure device. No pregnancies have been reported in our series to date. A significant reduction in the Essure device non-placement rate (20.0%vs 4.0%, P= 0.021) and mean operation time (27.3 vs 19.6 minutes, P= 0.006) were seen when patients were pre-medicated with spasmolytic agent and analgesia. The Essure permanent birth control device is safe and suitable for Asians. Its non-placement rate may be improved with pre-medication of spasmolytic agent and analgesia.
21 CFR 872.2060 - Jaw tracking device.
Code of Federal Regulations, 2014 CFR
2014-04-01
...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.2060 Jaw tracking device. (a) Jaw tracking device... Controls Guidance Document: Dental Sonography and Jaw Tracking Devices.” [68 FR 67367, Dec. 2, 2003] ...
Clark, Robert M.; Cronin, John C.
1977-01-01
A contamination control device for use in a gas-insulated transmission bus consisting of a cylindrical center conductor coaxially mounted within a grounded cylindrical enclosure. The contamination control device is electrically connected to the interior surface of the grounded outer shell and positioned along an axial line at the lowest vertical position thereon. The contamination control device comprises an elongated metallic member having a generally curved cross-section in a first plane perpendicular to the axis of the bus and having an arcuate cross-section in a second plane lying along the axis of the bus. Each opposed end of the metallic member and its opposing sides are tapered to form a pair of generally converging and downward sloping surfaces to trap randomly moving conductive particles in the relatively field-free region between the metallic member and the interior surface of the grounded outer shell. The device may have projecting legs to enable the device to be spot welded to the interior of the grounded housing. The control device provides a high capture probability and prevents subsequent release of the charged particles after the capture thereof.
Systems and methods to control multiple peripherals with a single-peripheral application code
Ransom, Ray M.
2013-06-11
Methods and apparatus are provided for enhancing the BIOS of a hardware peripheral device to manage multiple peripheral devices simultaneously without modifying the application software of the peripheral device. The apparatus comprises a logic control unit and a memory in communication with the logic control unit. The memory is partitioned into a plurality of ranges, each range comprising one or more blocks of memory, one range being associated with each instance of the peripheral application and one range being reserved for storage of a data pointer related to each peripheral application of the plurality. The logic control unit is configured to operate multiple instances of the control application by duplicating one instance of the peripheral application for each peripheral device of the plurality and partitioning a memory device into partitions comprising one or more blocks of memory, one partition being associated with each instance of the peripheral application. The method then reserves a range of memory addresses for storage of a data pointer related to each peripheral device of the plurality, and initializes each of the plurality of peripheral devices.
Coordinated garbage collection for raid array of solid state disks
Dillow, David A; Ki, Youngjae; Oral, Hakki S; Shipman, Galen M; Wang, Feiyi
2014-04-29
An optimized redundant array of solid state devices may include an array of one or more optimized solid-state devices and a controller coupled to the solid-state devices for managing the solid-state devices. The controller may be configured to globally coordinate the garbage collection activities of each of said optimized solid-state devices, for instance, to minimize the degraded performance time and increase the optimal performance time of the entire array of devices.
NASA Technical Reports Server (NTRS)
Studenick, D. K. (Inventor)
1977-01-01
An inlet leak is described for sampling gases, more specifically, for selectively sampling multiple fluids. This fluid sampling device includes a support frame. A plurality of fluid inlet devices extend through the support frame and each of the fluid inlet devices include a longitudinal aperture. An opening device that is responsive to a control signal selectively opens the aperture to allow fluid passage. A closing device that is responsive to another control signal selectively closes the aperture for terminating further fluid flow.
Sliding pressure control valve for pneumatic hammer drill
Polsky, Yarom [Albuquerque, NM
2011-08-30
A pneumatic device control apparatus and method comprising a ported valve slidably fitted over a feed tube of the pneumatic device, and using a compliant biasing device to constrain motion of the valve to provide asymmetric timing for extended pressurization of a power chamber and reduced pressurization of a return chamber of the pneumatic device. The pneumatic device can be a pneumatic hammer drill.
Network device interface for digitally interfacing data channels to a controller via a network
NASA Technical Reports Server (NTRS)
Konz, Daniel W. (Inventor); Winkelmann, Joseph P. (Inventor); Ellerbrock, Philip J. (Inventor); Grant, Robert L. (Inventor)
2007-01-01
The present invention provides a network device interface and method for digitally connecting a plurality of data channels, such as sensors, actuators, and subsystems, to a controller using a network bus. The network device interface interprets commands and data received from the controller and polls the data channels in accordance with these commands. Specifically, the network device interface receives digital commands and data from the controller, and based on these commands and data, communicates with the data channels to either retrieve data in the case of a sensor or send data to activate an actuator. Data retrieved from the sensor is converted into digital signals and transmitted to the controller. In some embodiments, network device interfaces associated with different data channels coordinate communications with the other interfaces based on either a transition in a command message sent by the bus controller or a synchronous clock signal.
Zheng, Song; Zhang, Qi; Zheng, Rong; Huang, Bi-Qin; Song, Yi-Lin; Chen, Xin-Chu
2017-01-01
In recent years, the smart home field has gained wide attention for its broad application prospects. However, families using smart home systems must usually adopt various heterogeneous smart devices, including sensors and devices, which makes it more difficult to manage and control their home system. How to design a unified control platform to deal with the collaborative control problem of heterogeneous smart devices is one of the greatest challenges in the current smart home field. The main contribution of this paper is to propose a universal smart home control platform architecture (IAPhome) based on a multi-agent system and communication middleware, which shows significant adaptability and advantages in many aspects, including heterogeneous devices connectivity, collaborative control, human-computer interaction and user self-management. The communication middleware is an important foundation to design and implement this architecture which makes it possible to integrate heterogeneous smart devices in a flexible way. A concrete method of applying the multi-agent software technique to solve the integrated control problem of the smart home system is also presented. The proposed platform architecture has been tested in a real smart home environment, and the results indicate that the effectiveness of our approach for solving the collaborative control problem of different smart devices. PMID:28926957
Zheng, Song; Zhang, Qi; Zheng, Rong; Huang, Bi-Qin; Song, Yi-Lin; Chen, Xin-Chu
2017-09-16
In recent years, the smart home field has gained wide attention for its broad application prospects. However, families using smart home systems must usually adopt various heterogeneous smart devices, including sensors and devices, which makes it more difficult to manage and control their home system. How to design a unified control platform to deal with the collaborative control problem of heterogeneous smart devices is one of the greatest challenges in the current smart home field. The main contribution of this paper is to propose a universal smart home control platform architecture (IAPhome) based on a multi-agent system and communication middleware, which shows significant adaptability and advantages in many aspects, including heterogeneous devices connectivity, collaborative control, human-computer interaction and user self-management. The communication middleware is an important foundation to design and implement this architecture which makes it possible to integrate heterogeneous smart devices in a flexible way. A concrete method of applying the multi-agent software technique to solve the integrated control problem of the smart home system is also presented. The proposed platform architecture has been tested in a real smart home environment, and the results indicate that the effectiveness of our approach for solving the collaborative control problem of different smart devices.
2017-12-27
The Food and Drug Administration (FDA or we) is classifying the flow cytometric test system for hematopoietic neoplasms into class II (special controls). The special controls that apply to the device type are identified in this order and will be part of the codified language for the flow cytometric test system for hematopoietic neoplasms' classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.
Code of Federal Regulations, 2011 CFR
2011-07-01
... system and add-on control device operating limits during the performance test? 63.4767 Section 63.4767... Rate with Add-on Controls Option § 63.4767 How do I establish the emission capture system and add-on control device operating limits during the performance test? During the performance test required by § 63...
Code of Federal Regulations, 2010 CFR
2010-07-01
... system and add-on control device operating limits during the performance test? 63.4767 Section 63.4767... Rate with Add-on Controls Option § 63.4767 How do I establish the emission capture system and add-on control device operating limits during the performance test? During the performance test required by § 63...
Code of Federal Regulations, 2010 CFR
2010-07-01
... system and add-on control device operating limits during the performance test? 63.4167 Section 63.4167... with Add-on Controls Option § 63.4167 How do I establish the emission capture system and add-on control device operating limits during the performance test? During the performance test required by § 63.4160...
Code of Federal Regulations, 2011 CFR
2011-07-01
... system and add-on control device operating limits during the performance test? 63.4167 Section 63.4167... with Add-on Controls Option § 63.4167 How do I establish the emission capture system and add-on control device operating limits during the performance test? During the performance test required by § 63.4160...
Code of Federal Regulations, 2010 CFR
2010-07-01
... flue gases at the inlet of my particulate matter control device? 62.15270 Section 62.15270 Protection....15270 How do I monitor the temperature of flue gases at the inlet of my particulate matter control... temperature of the flue gas stream at the inlet of each particulate matter control device. ...
Code of Federal Regulations, 2011 CFR
2011-07-01
... flue gases at the inlet of my particulate matter control device? 62.15270 Section 62.15270 Protection....15270 How do I monitor the temperature of flue gases at the inlet of my particulate matter control... temperature of the flue gas stream at the inlet of each particulate matter control device. ...
NASA Astrophysics Data System (ADS)
Onogaki, Hitoshi; Yokoyama, Shuichi
The temperature control of the environmental examination device has loss of the energy consumption to cool it while warming it. This paper proposed a tempareture control system method with energy saving for the enviromental examination device without using cooling in consideration of temperature characteristics.
40 CFR 60.5250 - What definitions must I know?
Code of Federal Regulations, 2011 CFR
2011-07-01
... used for discharging combustion gases to avoid severe damage to the air pollution control device or..., 2010. Fabric filter means an add-on air pollution control device used to capture particulate matter by...). (2) A change in the air pollution control devices used to comply with the emission limits for the...
40 CFR 60.5250 - What definitions must I know?
Code of Federal Regulations, 2013 CFR
2013-07-01
... used for discharging combustion gases to avoid severe damage to the air pollution control device or..., 2010. Fabric filter means an add-on air pollution control device used to capture particulate matter by...). (2) A change in the air pollution control devices used to comply with the emission limits for the...
40 CFR 60.5250 - What definitions must I know?
Code of Federal Regulations, 2014 CFR
2014-07-01
... used for discharging combustion gases to avoid severe damage to the air pollution control device or..., 2010. Fabric filter means an add-on air pollution control device used to capture particulate matter by...). (2) A change in the air pollution control devices used to comply with the emission limits for the...
40 CFR 60.5250 - What definitions must I know?
Code of Federal Regulations, 2012 CFR
2012-07-01
... used for discharging combustion gases to avoid severe damage to the air pollution control device or..., 2010. Fabric filter means an add-on air pollution control device used to capture particulate matter by...). (2) A change in the air pollution control devices used to comply with the emission limits for the...
40 CFR 63.3400 - What notifications and reports must I submit?
Code of Federal Regulations, 2010 CFR
2010-07-01
... unknown causes. (I) The date of the latest CEMS and CPMS certification or audit. (J) A description of any... control device and you are required to conduct a performance test of the control device. This notification... of the control device determined during the performance test are maintained. Unless EPA objects to...
Williams, J.V.
1984-04-26
Disclosed is a locking device for eliminating external control of a secured space formed by fixed and movable barriers. The locking device uses externally and internally controlled locksets and a movable strike, operable from the secured side of the movable barrier, to selectively engage either lockset. A disengagement device, for preventing forces from being applied to the lock bolts is also disclosed. In this manner, a secured space can be controlled from the secured side as a safe-haven. 4 figures.
System for remote control of underground device
Brumleve, T.D.; Hicks, M.G.; Jones, M.O.
1975-10-21
A system is described for remote control of an underground device, particularly a nuclear explosive. The system includes means at the surface of the ground for transmitting a seismic signal sequence through the earth having controlled and predetermined signal characteristics for initiating a selected action in the device. Additional apparatus, located with or adjacent to the underground device, produces electrical signals in response to the seismic signals received and compares these electrical signals with the predetermined signal characteristics.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-14
... Administration (FDA) is classifying the endovascular suturing system into class II (special controls). The Agency is classifying the device into class II (special controls) in order to provide a reasonable assurance..., or FDA issues an order finding the device to be substantially equivalent, in accordance with section...
Change control microcomputer device for vehicle
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morishita, M.; Kouge, S.
1986-08-19
A charge control microcomputer device for a vehicle is described which consists of: a clutch device for transmitting the rotary output of an engine; a charging generator driven by the clutch device; a battery charged by an output of the charging generator; a voltage regulator for controlling an output voltage of the charging generator to a predetermined value; an engine controlling microcomputer for receiving engine data, to control the engine; and a charge control microcomputer for processing the engine data from the engine controlling microcomputer and charge system data including terminal voltage data from the battery and generated voltage datamore » from the charging generator, to determine a reference voltage for the voltage regulator in accordance with the engine data and the charge system data, and for processing an engine rotation signal to generate and apply an operating instruction to the clutch device in accordance with the engine data and the charge system data, such that the charging generator is driven within a predetermined range of revolutions per minute at all times.« less
Traffic control device conspicuity.
DOT National Transportation Integrated Search
2013-08-01
The conspicuity of a traffic control device (TCD) is defined as the probability that the device will be noticed. However, there is no agreed-upon measure of what constitutes being noticed. Various measures have been suggested, including eye fixations...
40 CFR 63.773 - Inspection and monitoring requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... devices: (i) Except for control devices for small glycol dehydration units, a boiler or process heater in...) Except for control devices for small glycol dehydration units, a boiler or process heater with a design...
40 CFR 63.773 - Inspection and monitoring requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... devices: (i) Except for control devices for small glycol dehydration units, a boiler or process heater in...) Except for control devices for small glycol dehydration units, a boiler or process heater with a design...
Kencana, Andy Prima; Heng, John
2008-11-01
This paper introduces a novel passive tongue control and tracking device. The device is intended to be used by the severely disabled or quadriplegic person. The main focus of this device when compared to the other existing tongue tracking devices is that the sensor employed is passive which means it requires no powered electrical sensor to be inserted into the user's mouth and hence no trailing wires. This haptic interface device employs the use of inductive sensors to track the position of the user's tongue. The device is able perform two main PC functions that of the keyboard and mouse function. The results show that this device allows the severely disabled person to have some control in his environment, such as to turn on and off or control daily electrical devices or appliances; or to be used as a viable PC Human Computer Interface (HCI) by tongue control. The operating principle and set-up of such a novel passive tongue HCI has been established with successful laboratory trials and experiments. Further clinical trials will be required to test out the device on disabled persons before it is ready for future commercial development.
Electrical device fabrication from nanotube formations
Nicholas, Nolan Walker; Kittrell, W. Carter; Kim, Myung Jong; Schmidt, Howard K.
2013-03-12
A method for forming nanotube electrical devices, arrays of nanotube electrical devices, and device structures and arrays of device structures formed by the methods. Various methods of the present invention allow creation of semiconducting and/or conducting devices from readily grown SWNT carpets rather than requiring the preparation of a patterned growth channel and takes advantage of the self-controlling nature of these carpet heights to ensure a known and controlled channel length for reliable electronic properties as compared to the prior methods.
Designing Security-Hardened Microkernels For Field Devices
NASA Astrophysics Data System (ADS)
Hieb, Jeffrey; Graham, James
Distributed control systems (DCSs) play an essential role in the operation of critical infrastructures. Perimeter field devices are important DCS components that measure physical process parameters and perform control actions. Modern field devices are vulnerable to cyber attacks due to their increased adoption of commodity technologies and that fact that control networks are no longer isolated. This paper describes an approach for creating security-hardened field devices using operating system microkernels that isolate vital field device operations from untrusted network-accessible applications. The approach, which is influenced by the MILS and Nizza architectures, is implemented in a prototype field device. Whereas, previous microkernel-based implementations have been plagued by poor inter-process communication (IPC) performance, the prototype exhibits an average IPC overhead for protected device calls of 64.59 μs. The overall performance of field devices is influenced by several factors; nevertheless, the observed IPC overhead is low enough to encourage the continued development of the prototype.
State-of-the-art robotic devices for ankle rehabilitation: Mechanism and control review.
Hussain, Shahid; Jamwal, Prashant K; Ghayesh, Mergen H
2017-12-01
There is an increasing research interest in exploring use of robotic devices for the physical therapy of patients suffering from stroke and spinal cord injuries. Rehabilitation of patients suffering from ankle joint dysfunctions such as drop foot is vital and therefore has called for the development of newer robotic devices. Several robotic orthoses and parallel ankle robots have been developed during the last two decades to augment the conventional ankle physical therapy of patients. A comprehensive review of these robotic ankle rehabilitation devices is presented in this article. Recent developments in the mechanism design, actuation and control are discussed. The study encompasses robotic devices for treadmill and over-ground training as well as platform-based parallel ankle robots. Control strategies for these robotic devices are deliberated in detail with an emphasis on the assist-as-needed training strategies. Experimental evaluations of the mechanism designs and various control strategies of these robotic ankle rehabilitation devices are also presented.
NASA Astrophysics Data System (ADS)
Scolari, Lara; Tanggaard Alkeskjold, Thomas; Riishede, Jesper; Bjarklev, Anders; Sparre Hermann, David; Anawati, Anawati; Dybendal Nielsen, Martin; Bassi, Paolo
2005-09-01
We present an electrically controlled photonic bandgap fiber device obtained by infiltrating the air holes of a photonic crystal fiber (PCF) with a dual-frequency liquid crystal (LC) with pre-tilted molecules. Compared to previously demonstrated devices of this kind, the main new feature of this one is its continuous tunability due to the fact that the used LC does not exhibit reverse tilt domain defects and threshold effects. Furthermore, the dual-frequency features of the LC enables electrical control of the spectral position of the bandgaps towards both shorter and longer wavelengths in the same device. We investigate the dynamics of this device and demonstrate a birefringence controller based on this principle.
Rotatable non-circular forebody flow controller
NASA Technical Reports Server (NTRS)
Moskovitz, Cary A. (Inventor)
1991-01-01
The invention is a rotatable, non-circular forebody flow controller. The apparatus comprises a small geometric device located at a nose of a forebody of an aircraft and a non-circular cross-sectional area that extends toward the apex of the aircraft. The device is symmetrical about a reference plane and preferably attaches to an axle which in turn attaches to a rotating motor. The motor rotates the device about an axis of rotation. Preferably, a control unit connected to an aircraft flight control computer signals to the rotating motor the proper rotational positioning of the geometric device.
NASA Technical Reports Server (NTRS)
Cukor, P. M.; Chapman, R. A.
1978-01-01
The uncertainties and associated costs involved in selecting and designing a particulate control device to meet California's air emission regulations are considered. The basic operating principles of electrostatic precipitators and fabric filters are discussed, and design parameters are identified. The size and resulting cost of the control device as a function of design parameters is illustrated by a case study for an 800 MW coal-fired fired utility boiler burning a typical southwestern subbituminous coal. The cost of selecting an undersized particulate control device is compared with the cost of selecting an oversized device.
Seismic Response Control Of Structures Using Semi-Active and Passive Variable Stiffness Devices
NASA Astrophysics Data System (ADS)
Salem, Mohamed M. A.
Controllable devices such as Magneto-Rheological Fluid Dampers, Electro-Rheological Dampers, and controllable friction devices have been studied extensively with limited implementation in real structures. Such devices have shown great potential in reducing seismic demands, either as smart base isolation systems, or as smart devices for multistory structures. Although variable stiffness devices can be used for seismic control of structures, the vast majority of research effort has been given to the control of damping. The primary focus of this dissertation is to evaluate the seismic control of structures using semi-active and passive variable stiffness characteristics. Smart base isolation systems employing variable stiffness devices have been studied, and two semi-active control strategies are proposed. The control algorithms were designed to reduce the superstructure and base accelerations of seismically isolated structures subject to near-fault and far-field ground motions. Computational simulations of the proposed control algorithms on the benchmark structure have shown that excessive base displacements associated with the near-fault ground motions may be better mitigated with the use of variable stiffness devices. However, the device properties must be controllable to produce a wide range of stiffness changes for an effective control of the base displacements. The potential of controllable stiffness devices in limiting the base displacement due to near-fault excitation without compromising the performance of conventionally isolated structures, is illustrated. The application of passive variable stiffness devices for seismic response mitigation of multistory structures is also investigated. A stiffening bracing system (SBS) is proposed to replace the conventional bracing systems of braced frames. An optimization process for the SBS parameters has been developed. The main objective of the design process is to maintain a uniform inter-story drift angle over the building's height, which in turn would evenly distribute the seismic demand over the building. This behavior is particularly essential so that any possible damage is not concentrated in a single story. Furthermore, the proposed design ensures that additional damping devices distributed over the building's height work efficiently with their maximum design capacity, leading to a cost efficient design. An integrated and comprehensive design procedure that can be readily adopted by the current seismic design codes is proposed. An equivalent lateral force distribution is developed that shows a good agreement with the response history analyses in terms of seismic performance and demand prediction. This lateral force pattern explicitly accounts for the higher mode effect, the dynamic characteristics of the structure, the supplemental damping, and the site specific seismic hazard. Therefore, the proposed design procedure is considered as a standalone method for the design of SBS equipped buildings.
Ikehara, Tadaaki; Nagamura, Kazuteru; Ushida, Takurou; Tanaka, Eiichirou; Saegusa, Shozo; Kojima, Sho; Yuge, Louis
2011-01-01
A walking assistance device using a flexible shaft was developed. The combination of a flexible shaft with a worm gear was successfully adopted on this device to simplify its appearance and reduce its size. A hybrid - control system on this device controls both torque and angle at the ankle and knee joints. In this system, the torsional spring constant of the flexible shaft is taken into account by the motor in controlling the power and angle of rotation of the motor. To expand the area in which a person may use the device, it is equipped with a self-contained system powered by a Lithium-ion battery and controlled by an SH-4 microcomputer and actuators, consisting of motors and gears, all of which are carried in a small backpack. Consequently, persons using the device may walk freely in both indoor and outdoor environments. © 2011 IEEE
Estimating the impact of birth control on fertility rate in sub-Saharan Africa.
Ijaiya, Gafar T; Raheem, Usman A; Olatinwo, Abdulwaheed O; Ijaiya, Munir-Deen A; Ijaiya, Mukaila A
2009-12-01
Using a cross-country data drawn from 40 countries and a multiple regression analysis, this paper examines the impact of birth control devices on the rate of fertility in sub-Saharan Africa. Our a-priori expectations are that the more women used birth control devices, the less will be the fertility rate in sub-Saharan Africa. The result obtained from the study indicates that except for withdrawal method that fall contrary to our expectation other variables (methods) like the use of pills, injection, intra uterine device (IUD), condom/diaphragm and cervical cap, female sterilization and periodic abstinence/rhythm fulfilled our a-priori expectations. These results notwithstanding, the paper suggests measures, such as the need for massive enlightenment campaign on the benefit of these birth control devices, the frequent checking of the potency of the devices and good governance in the delivery of the devices
The service telemetry and control device for space experiment “GRIS”
NASA Astrophysics Data System (ADS)
Glyanenko, A. S.
2016-02-01
Problems of scientific devices control (for example, fine control of measuring paths), collecting auxiliary (service information about working capacity, conditions of experiment carrying out, etc.) and preliminary data processing are actual for any space device. Modern devices for space research it is impossible to imagine without devices that didn't use digital data processing methods and specialized or standard interfaces and computing facilities. For realization of these functions in “GRIS” experiment onboard ISS for purposes minimization of dimensions, power consumption, the concept “system-on-chip” was chosen and realized. In the programmable logical integrated scheme by Microsemi from ProASIC3 family with maximum capacity up to 3M system gates, the computing kernel and all necessary peripherals are created. In this paper we discuss structure, possibilities and resources the service telemetry and control device for “GRIS” space experiment.
NASA Astrophysics Data System (ADS)
Denn, Michael E.
Several recent studies have shown the advantages of active and/or passive flow control devices for boundary layer flow modification. Many current and future proposed air vehicles have very short or offset diffusers in order to save vehicle weight and create more optimal vehicle/engine integration. Such short coupled diffusers generally result in boundary layer separation and loss of pressure recovery which reduces engine performance and in some cases may cause engine stall. Deployment of flow control devices can alleviate this problem to a large extent; however, almost all active flow control devices have some energy penalty associated with their inclusion. One potential low penalty approach for enhancing the diffuser performance is to combine the passive flow control elements such as micro-ramps with active flow control devices such as synthetic jets to achieve higher control authority. The goal of this dissertation is twofold. The first objective is to assess the ability of CFD with URANS turbulence models to accurately capture the effects of the synthetic jets and micro-ramps on boundary layer flow. This is accomplished by performing numerical simulations replicating several experimental test cases conducted at Georgia Institute of Technology under the NASA funded Inlet Flow Control and Prediction Technologies Program, and comparing the simulation results with experimental data. The second objective is to run an expanded CFD matrix of numerical simulations by varying various geometric and other flow control parameters of micro-ramps and synthetic jets to determine how passive and active control devices interact with each other in increasing and/or decreasing the control authority and determine their influence on modification of boundary layer flow. The boundary layer shape factor is used as a figure of merit for determining the boundary layer flow quality/modification and its tendency towards separation. It is found by a large number of numerical experiments and the analysis of simulation data that a flow control device's influence on boundary layer quality is a function of three factors: (1) the strength of the longitudinal vortex emanating from the flow control device or devices, (2) the height of the vortex core above the surface and, when a synthetic jet is present, (3) the momentum added to the boundary layer flow.
NASA Technical Reports Server (NTRS)
Barret, Chris
1995-01-01
Report describes study of aerodynamic flight-control-augmentation devices proposed for use in increasing payload capabilities of future launch vehicles by allowing more aft centers of gravity. Proposed all-movable devices not only provide increased control authority during ascent trajectory, but also reduce engine gimballing requirements and enhance crew safety. Report proposes various aerodynamic control surfaces mounted fore and aft on Saturn-class launch vehicle.
Magnelok technology: a complement to magnetorheological fluids
NASA Astrophysics Data System (ADS)
Carlson, J. David
2004-07-01
Magnetorheological or MR fluids have been successfully used to enable highly effective semi-active control systems in automobile primary suspensions to control unwanted motions in civil engineering structures and to provide force-feedback in steer-by-wire systems. A key to the successful use of MR fluids is an appreciation and understanding of the balance and trade-off between the magnetically controlled on-state force and the ever-present off-state viscous force. In all MR fluid applications, one must deal with the fact that MR fluids never fully decouple or go to zero force in their off-state. Magnelok devices are a magnetically controlled compliment to traditional MR fluid devices that have been developed to enable a true force decoupling in the off-state. Magnelok devices may be embodied as linear or rotary dampers, brakes, lockable struts or position holding devices. They are particularly suitable for lock/un-lock applications. Unlike MR fluid devices they contain no fluid yet they do provide a variable level of friction damping that is controlled by the magnitude of the applied magnetic field. Magnelok devices are low cost as they easily accommodate relatively loose mechanical tolerances and require no seals or accumulator. A variety of controllable Magnelok devices and applications are described.
Dynamic Optical Grating Device and Associated Method for Modulating Light
NASA Technical Reports Server (NTRS)
Park, Yeonjoon (Inventor); Choi, Sang H. (Inventor); King, Glen C. (Inventor); Chu, Sang-Hyon (Inventor)
2012-01-01
A dynamic optical grating device and associated method for modulating light is provided that is capable of controlling the spectral properties and propagation of light without moving mechanical components by the use of a dynamic electric and/or magnetic field. By changing the electric field and/or magnetic field, the index of refraction, the extinction coefficient, the transmittivity, and the reflectivity fo the optical grating device may be controlled in order to control the spectral properties of the light reflected or transmitted by the device.
SeleCon: Scalable IoT Device Selection and Control Using Hand Gestures.
Alanwar, Amr; Alzantot, Moustafa; Ho, Bo-Jhang; Martin, Paul; Srivastava, Mani
2017-04-01
Although different interaction modalities have been proposed in the field of human-computer interface (HCI), only a few of these techniques could reach the end users because of scalability and usability issues. Given the popularity and the growing number of IoT devices, selecting one out of many devices becomes a hurdle in a typical smarthome environment. Therefore, an easy-to-learn, scalable, and non-intrusive interaction modality has to be explored. In this paper, we propose a pointing approach to interact with devices, as pointing is arguably a natural way for device selection. We introduce SeleCon for device selection and control which uses an ultra-wideband (UWB) equipped smartwatch. To interact with a device in our system, people can point to the device to select it then draw a hand gesture in the air to specify a control action. To this end, SeleCon employs inertial sensors for pointing gesture detection and a UWB transceiver for identifying the selected device from ranging measurements. Furthermore, SeleCon supports an alphabet of gestures that can be used for controlling the selected devices. We performed our experiment in a 9 m -by-10 m lab space with eight deployed devices. The results demonstrate that SeleCon can achieve 84.5% accuracy for device selection and 97% accuracy for hand gesture recognition. We also show that SeleCon is power efficient to sustain daily use by turning off the UWB transceiver, when a user's wrist is stationary.
SeleCon: Scalable IoT Device Selection and Control Using Hand Gestures
Alanwar, Amr; Alzantot, Moustafa; Ho, Bo-Jhang; Martin, Paul; Srivastava, Mani
2018-01-01
Although different interaction modalities have been proposed in the field of human-computer interface (HCI), only a few of these techniques could reach the end users because of scalability and usability issues. Given the popularity and the growing number of IoT devices, selecting one out of many devices becomes a hurdle in a typical smarthome environment. Therefore, an easy-to-learn, scalable, and non-intrusive interaction modality has to be explored. In this paper, we propose a pointing approach to interact with devices, as pointing is arguably a natural way for device selection. We introduce SeleCon for device selection and control which uses an ultra-wideband (UWB) equipped smartwatch. To interact with a device in our system, people can point to the device to select it then draw a hand gesture in the air to specify a control action. To this end, SeleCon employs inertial sensors for pointing gesture detection and a UWB transceiver for identifying the selected device from ranging measurements. Furthermore, SeleCon supports an alphabet of gestures that can be used for controlling the selected devices. We performed our experiment in a 9m-by-10m lab space with eight deployed devices. The results demonstrate that SeleCon can achieve 84.5% accuracy for device selection and 97% accuracy for hand gesture recognition. We also show that SeleCon is power efficient to sustain daily use by turning off the UWB transceiver, when a user’s wrist is stationary. PMID:29683151
40 CFR 60.734 - Monitoring of emissions and operations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... operator of an affected facility subject to the provisions of this subpart who uses a dry control device to... control device. (b) In lieu of a continuous opacity monitoring system, the owner or operator of a ball... vermiculite fluid bed dryer, or a vermiculite rotary dryer who uses a dry control device may have a certified...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-17
... traffic control devices used on all streets, highways, bikeways, and private roads open to public travel... restructuring the MUTCD into two documents at this time. FOR FURTHER INFORMATION CONTACT: For questions about... do this; however, it is unclear at this time where this material would be located. It could be...
Human research review of the TASER electronic control device.
Ho, Jeffrey D; Dawes, Donald M; Heegaard, William G; Miner, James R
2009-01-01
TASER Electronic Control Devices have become mainstream methods of applying electricity to control unruly suspects. There has been speculation that they may be associated with worsening human physiology or death. The lay impressions that these devices are unsafe are not founded on known human research findings. This presentation briefly reviews the most pertinent human research on this subject.
Code of Federal Regulations, 2014 CFR
2014-07-01
... capture system and add-on control device operating limits during the performance test? 63.3556 Section 63... system and add-on control device operating limits during the performance test? During the performance... of key parameters of the valve operating system (e.g., solenoid valve operation, air pressure...
Code of Federal Regulations, 2012 CFR
2012-07-01
... capture system and add-on control device operating limits during the performance test? 63.3556 Section 63... system and add-on control device operating limits during the performance test? During the performance... of key parameters of the valve operating system (e.g., solenoid valve operation, air pressure...
Code of Federal Regulations, 2014 CFR
2014-07-01
... capture system and add-on control device operating limits during the performance test? 63.4966 Section 63... system and add-on control device operating limits during the performance test? During the performance... outlet gas temperature is the maximum operating limit for your condenser. (e) Emission capture system...
Code of Federal Regulations, 2012 CFR
2012-07-01
... capture system and add-on control device operating limits during the performance test? 63.4966 Section 63... system and add-on control device operating limits during the performance test? During the performance... outlet gas temperature is the maximum operating limit for your condenser. (e) Emission capture system...
40 CFR 63.130 - Transfer operations provisions-periodic recordkeeping and reporting.
Code of Federal Regulations, 2014 CFR
2014-07-01
... from the control device is used, each owner or operator of a Group 1 transfer rack subject to the... owner or operator using a control device to comply with § 63.126(b)(1) or (b)(2) of this subpart shall... vented to the control device, continuous records of the equipment operating parameters specified to be...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Compliance Requirements § 60.4895 By what date must I conduct annual air pollution control device inspections and make any necessary repairs? (a) You must conduct an annual inspection of each air pollution... following the previous annual air pollution control device inspection. (b) Within 10 operating days...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Compliance Requirements § 60.4895 By what date must I conduct annual air pollution control device inspections and make any necessary repairs? (a) You must conduct an annual inspection of each air pollution... following the previous annual air pollution control device inspection. (b) Within 10 operating days...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Compliance Requirements § 60.4895 By what date must I conduct annual air pollution control device inspections and make any necessary repairs? (a) You must conduct an annual inspection of each air pollution... following the previous annual air pollution control device inspection. (b) Within 10 operating days...
Code of Federal Regulations, 2011 CFR
2011-07-01
... device emission destruction or removal efficiency? 63.4166 Section 63.4166 Protection of Environment....4166 How do I determine the add-on control device emission destruction or removal efficiency? (a) For... device organic emissions destruction or removal efficiency, using Equation 2 of this section. ER23JY02...
3D elastic control for mobile devices.
Hachet, Martin; Pouderoux, Joachim; Guitton, Pascal
2008-01-01
To increase the input space of mobile devices, the authors developed a proof-of-concept 3D elastic controller that easily adapts to mobile devices. This embedded device improves the completion of high-level interaction tasks such as visualization of large documents and navigation in 3D environments. It also opens new directions for tomorrow's mobile applications.
Code of Federal Regulations, 2013 CFR
2013-07-01
... system and add-on control device operating limits during the performance test? 63.3546 Section 63.3546... of key parameters of the valve operating system (e.g., solenoid valve operation, air pressure... minimum operating limit for that specific capture device or system of multiple capture devices. The...
Code of Federal Regulations, 2014 CFR
2014-07-01
... capture system and add-on control device operating limits during the performance test? 63.3546 Section 63... of key parameters of the valve operating system (e.g., solenoid valve operation, air pressure... minimum operating limit for that specific capture device or system of multiple capture devices. The...
Code of Federal Regulations, 2012 CFR
2012-07-01
... capture system and add-on control device operating limits during the performance test? 63.3546 Section 63... of key parameters of the valve operating system (e.g., solenoid valve operation, air pressure... minimum operating limit for that specific capture device or system of multiple capture devices. The...
System and method for networking electrochemical devices
Williams, Mark C.; Wimer, John G.; Archer, David H.
1995-01-01
An improved electrochemically active system and method including a plurality of electrochemical devices, such as fuel cells and fluid separation devices, in which the anode and cathode process-fluid flow chambers are connected in fluid-flow arrangements so that the operating parameters of each of said plurality of electrochemical devices which are dependent upon process-fluid parameters may be individually controlled to provide improved operating efficiency. The improvements in operation include improved power efficiency and improved fuel utilization in fuel cell power generating systems and reduced power consumption in fluid separation devices and the like through interstage process fluid parameter control for series networked electrochemical devices. The improved networking method includes recycling of various process flows to enhance the overall control scheme.
40 CFR 1036.801 - Definitions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... control device means any element of design that senses temperature, motive speed, engine RPM, transmission.... Emission control system means any device, system, or element of design that controls or reduces the... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF...
40 CFR 1036.801 - Definitions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... control device means any element of design that senses temperature, motive speed, engine RPM, transmission.... Emission control system means any device, system, or element of design that controls or reduces the... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF...
Traffic control device conspicuity, TechBrief
DOT National Transportation Integrated Search
2013-09-01
The conspicuity of a traffic control device (TCD) is defined as the probability that the device will be noticed. However, there is no agreed-upon measure of what constitutes being noticed. Various measures such as eye fixations, recall, and other ver...
The EPICS-based remote control system for muon beam line devices at J-PARC MUSE
NASA Astrophysics Data System (ADS)
Ito, T. U.; Nakahara, K.; Kawase, M.; Fujimori, H.; Kobayashi, Y.; Higemoto, W.; Miyake, Y.
2010-04-01
The remote control system for muon beam line devices of J-PARC MUSE has been developed with the Experimental Physics and Industrial Control System (EPICS). The EPICS input/output controller was installed in standard Linux PCs for slow control of the devices. Power supplies for 21 magnetic elements and four slit controllers for the decay-surface muon beam line in the Materials and Life Science Experimental Facility are now accessible via Ethernet from a graphical user interface which has been composed using the Motif Editor and Display Manger.
Custódio, Kauê Muller; Oliveira, Joice Guilherme de; Moterle, Diego; Zepon, Karine Modolon; Prophiro, Josiane Somariva; Kanis, Luiz Alberto
2016-01-01
The significant increase in dengue, Zika, and chikungunya and the resistance of the Aedes aegypti mosquito to major insecticides emphasize the importance of studying alternatives to control this vector. The aim of this study was to develop a controlled-release device containing Piper nigrum extract and to study its larvicidal activity against Aedes aegypti. Piper nigrum extract was produced by maceration, standardized in piperine, and incorporated into cotton threads, which were inserted into hydrogel cylinders manufactured by the extrusion of carrageenan and carob. The piperine content of the extract and thread reservoirs was quantified by chromatography. The release profile from the device was assessed in aqueous medium and the larvicidal and residual activities of the standardized extract as well as of the controlled-release device were examined in Aedes aegypti larvae. The standardized extract contained 580mg/g of piperine and an LC50 value of 5.35ppm (24h) and the 3 cm thread reservoirs contained 13.83 ± 1.81mg of piperine. The device showed zero-order release of piperine for 16 days. The P. nigrum extract (25ppm) showed maximum residual larvicidal activity for 10 days, decreasing progressively thereafter. The device had a residual larvicidal activity for up to 37 days. The device provided controlled release of Piper nigrum extract with residual activity for 37 days. The device is easy to manufacture and may represent an effective alternative for the control of Aedes aegypti larvae in small water containers.
Lee, Doug-Youn; Spångberg, Larz S W; Bok, Young-Bin; Lee, Chang-Young; Kum, Kee-Yeon
2005-07-01
The aim of this in vitro study was to evaluate the suitability of using chitosan, poly (lactide-co-glycolide) (PLGA), and polymethyl methacrylate (PMMA) to control the release of chlorhexidine digluconate (CHX) from a prototype of controlled release drug device for root canal disinfection. Four different prototypes with different formulations were prepared. Group A (n = 12): the device (absorbent paper point) was loaded with CHX as control. Group B (n = 12): same as group A, but the device was coated with chitosan (Texan MedTech). In Groups C and D, the device was treated in the same way as group A and then coated 3 times with 5% PMMA (Group C, n = 12, Aldrich), or coated 3 times with 3% PLGA (Group D, n = 12, Sigma). The devices were randomly allocated to experimental groups of 12 each. All the prototypes of controlled release drug device were soaked in 3 mL distilled water. The concentrations of CHX were determined using a UV spectrophotometer. The surface characteristics of each prototype were observed using a scanning electron microscope. The result showed that release rate of CHX was the greatest in the noncoated group, followed by the chitosan-coated group, the PLGA-coated group, and the PMMA-coated group (P < 0.05). Pores were observed on the surface of the prototypes that were coated with PLGA and PMMA. When the pore size was smaller, the release rate was lower. These data indicate that polymer coating can control the release rate of CHX from the prototypes of controlled release drug device.
Dual control active superconductive devices
Martens, Jon S.; Beyer, James B.; Nordman, James E.; Hohenwarter, Gert K. G.
1993-07-20
A superconducting active device has dual control inputs and is constructed such that the output of the device is effectively a linear mix of the two input signals. The device is formed of a film of superconducting material on a substrate and has two main conduction channels, each of which includes a weak link region. A first control line extends adjacent to the weak link region in the first channel and a second control line extends adjacent to the weak link region in the second channel. The current flowing from the first channel flows through an internal control line which is also adjacent to the weak link region of the second channel. The weak link regions comprise small links of superconductor, separated by voids, through which the current flows in each channel. Current passed through the control lines causes magnetic flux vortices which propagate across the weak link regions and control the resistance of these regions. The output of the device taken across the input to the main channels and the output of the second main channel and the internal control line will constitute essentially a linear mix of the two input signals imposed on the two control lines. The device is especially suited to microwave applications since it has very low input capacitance, and is well suited to being formed of high temperature superconducting materials since all of the structures may be formed coplanar with one another on a substrate.
Implementation of Adaptive Digital Controllers on Programmable Logic Devices
NASA Technical Reports Server (NTRS)
Gwaltney, David A.; King, Kenneth D.; Smith, Keary J.; Montenegro, Justino (Technical Monitor)
2002-01-01
Much has been made of the capabilities of Field Programmable Gate Arrays (FPGA's) in the hardware implementation of fast digital signal processing functions. Such capability also makes an FPGA a suitable platform for the digital implementation of closed loop controllers. Other researchers have implemented a variety of closed-loop digital controllers on FPGA's. Some of these controllers include the widely used Proportional-Integral-Derivative (PID) controller, state space controllers, neural network and fuzzy logic based controllers. There are myriad advantages to utilizing an FPGA for discrete-time control functions which include the capability for reconfiguration when SRAM- based FPGA's are employed, fast parallel implementation of multiple control loops and implementations that can meet space level radiation tolerance requirements in a compact form-factor. Generally, a software implementation on a Digital Signal Processor (DSP) device or microcontroller is used to implement digital controllers. At Marshall Space Flight Center, the Control Electronics Group has been studying adaptive discrete-time control of motor driven actuator systems using DSP devices. While small form factor, commercial DSP devices are now available with event capture, data conversion, Pulse Width Modulated (PWM) outputs and communication peripherals, these devices are not currently available in designs and packages which meet space level radiation requirements. In general, very few DSP devices are produced that are designed to meet any level of radiation tolerance or hardness. An alternative is required for compact implementation of such functionality to withstand the harsh environment encountered on spacemap. The goal of this effort is to create a fully digital, flight ready controller design that utilizes an FPGA for implementation of signal conditioning for control feedback signals, generation of commands to the controlled system, and hardware insertion of adaptive-control algorithm approaches. Radiation tolerant FPGA's are a feasible option for reaching this goal.
Han, Su-Ting; Zhou, Ye; Yang, Qing Dan; Zhou, Li; Huang, Long-Biao; Yan, Yan; Lee, Chun-Sing; Roy, Vellaisamy A L
2014-02-25
Tunable memory characteristics are used in multioperational mode circuits where memory cells with various functionalities are needed in one combined device. It is always a challenge to obtain control over threshold voltage for multimode operation. On this regard, we use a strategy of shifting the work function of reduced graphene oxide (rGO) in a controlled manner through doping gold chloride (AuCl3) and obtained a gradient increase of rGO work function. By inserting doped rGO as floating gate, a controlled threshold voltage (Vth) shift has been achieved in both p- and n-type low voltage flexible memory devices with large memory window (up to 4 times for p-type and 8 times for n-type memory devices) in comparison with pristine rGO floating gate memory devices. By proper energy band engineering, we demonstrated a flexible floating gate memory device with larger memory window and controlled threshold voltage shifts.
NASA Astrophysics Data System (ADS)
Sihombing, Oloan; Zendrato, Niskarto; Laia, Yonata; Nababan, Marlince; Sitanggang, Delima; Purba, Windania; Batubara, Diarmansyah; Aisyah, Siti; Indra, Evta; Siregar, Saut
2018-04-01
In the era of technological development today, the technology has become the need for the life of today's society. One is needed to create a smart home in turning on and off electronic devices via smartphone. So far in turning off and turning the home electronic device is done by pressing the switch or remote button, so in control of electronic device control less effective. The home smart design is done by simulation concept by testing system, network configuration, and wireless home gateway computer network equipment required by a smart home network on cisco packet tracer using Internet Thing (IoT) control. In testing the IoT home network wireless network gateway system, multiple electronic devices can be controlled and monitored via smartphone based on predefined configuration conditions. With the Smart Ho me can potentially increase energy efficiency, decrease energy usage costs, control electronics and change the role of residents.
Lin, Li-Fong; Lin, Yi-Jia; Lin, Zi-Hao; Chuang, Li-Yun; Hsu, Wei-Chun; Lin, Yuan-Hsiang
2017-06-19
Wearable devices based on inertial measurement units through wireless sensor networks have many applications such as real-time motion monitoring and functional outcome assessment of stroke rehabilitation. However, additional investigations are warranted to validate their clinical value, particularly in detecting the synergy patterns of movements after stroke. To explore the feasibility and efficacy of wearable devices for upper limb rehabilitation in patients with chronic stroke and to compare the intervention effects (e.g., neurological recovery, active range of motion, and deviation angle) with those in a control group. A single-blind, randomized-controlled pilot study. Rehabilitation ward. A total of 18 patients with chronic stroke were randomly distributed into a device group and control group. Both groups received conventional rehabilitation; nevertheless, the device group was additionally subjected to 15 daily sessions at least three times a week for 5 weeks. The outcome measures included the upper extremity subscores of the Fugl-Meyer assessment, active range of motion, and deviation angle. These measurements were performed pre- and post-treatment. All five Fugl-Meyer assessment subscores improved in both the device and control groups after intervention; in particular, the "shoulder/elbow/forearm" subscore (p = 0.02, 0.03) and "total score" (p = 0.03, 0.03) substantially improved. The active range of motion of shoulder flexion and abduction substantially improved at pre-post treatment in both the device (p = 0.02, 0.03) and control (p = 0.02, 0.03) groups. The deviation angle of shoulder external rotation during shoulder abduction substantially improved in the device group (p = 0.02), but not in the control group. The designed wearable devices are practical and efficient for use in chronic patients with stroke. Wearable devices are expected to be useful for future internet-of-things rehabilitation clinical trials at home and in long-term care institutions.
Essebag, Vidal; Verma, Atul; Healey, Jeff S; Krahn, Andrew D; Kalfon, Eli; Coutu, Benoit; Ayala-Paredes, Felix; Tang, Anthony S; Sapp, John; Sturmer, Marcio; Keren, Arieh; Wells, George A; Birnie, David H
2016-03-22
The BRUISE CONTROL trial (Bridge or Continue Coumadin for Device Surgery Randomized Controlled Trial) demonstrated that a strategy of continued warfarin during cardiac implantable electronic device surgery was safe and reduced the incidence of clinically significant pocket hematoma (CSH). CSH was defined as a post-procedure hematoma requiring further surgery and/or resulting in prolongation of hospitalization of at least 24 h, and/or requiring interruption of anticoagulation. Previous studies have inconsistently associated hematoma with the subsequent development of device infection; reasons include the retrospective nature of many studies, lack of endpoint adjudication, and differing subjective definitions of hematoma. The BRUISE CONTROL INFECTION (Bridge or Continue Coumadin for Device Surgery Randomized Controlled Trial Extended Follow-Up for Infection) prospectively examined the association between CSH and subsequent device infection. The study included 659 patients with a primary outcome of device-related infection requiring hospitalization, defined as 1 or more of the following: pocket infection; endocarditis; and bloodstream infection. Outcomes were verified by a blinded adjudication committee. Multivariable analysis was performed to identify predictors of infection. The overall 1-year device-related infection rate was 2.4% (16 of 659). Infection occurred in 11% of patients (7 of 66) with previous CSH and in 1.5% (9 of 593) without CSH. CSH was the only independent predictor and was associated with a >7-fold increased risk of infection (hazard ratio: 7.7; 95% confidence interval: 2.9 to 20.5; p < 0.0001). Empiric antibiotics upon development of hematoma did not reduce long-term infection risk. CSH is associated with a significantly increased risk of infection requiring hospitalization within 1 year following cardiac implantable electronic device surgery. Strategies aimed at reducing hematomas may decrease the long-term risk of infection. (Bridge or Continue Coumadin for Device Surgery Randomized Controlled Trial [BRUISE CONTROL]; NCT00800137). Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Variable pressure thermal insulating jacket
Nelson, Paul A.; Malecha, Richard F.; Chilenskas, Albert A.
1994-01-01
A device for controlled insulation of a thermal device. The device includes a thermal jacket with a closed volume able to be evacuated to form an insulating jacket around the thermal source. A getter material is in communcation with the closed volume of the thermal jacket. The getter material can absorb and desorb a control gas to control gas pressure in the volume of the thermal jacket to control thermal conductivity in the thermal jacket.
Electric turbocompound control system
Algrain, Marcelo C [Dunlap, IL
2007-02-13
Turbocompound systems can be used to affect engine operation using the energy in exhaust gas that is driving the available turbocharger. A first electrical device acts as a generator in response to turbocharger rotation. A second electrical device acts as a motor to put mechanical power into the engine, typically at the crankshaft. Apparatus, systems, steps, and methods are described to control the generator and motor operations to control the amount of power being recovered. This can control engine operation closer to desirable parameters for given engine-related operating conditions compared to actual. The electrical devices can also operate in "reverse," going between motor and generator functions. This permits the electrical device associated with the crankshaft to drive the electrical device associated with the turbocharger as a motor, overcoming deficient engine operating conditions such as associated with turbocharger lag.
Evaluation of the leap motion controller as a new contact-free pointing device.
Bachmann, Daniel; Weichert, Frank; Rinkenauer, Gerhard
2014-12-24
This paper presents a Fitts' law-based analysis of the user's performance in selection tasks with the Leap Motion Controller compared with a standard mouse device. The Leap Motion Controller (LMC) is a new contact-free input system for gesture-based human-computer interaction with declared sub-millimeter accuracy. Up to this point, there has hardly been any systematic evaluation of this new system available. With an error rate of 7.8% for the LMC and 2.8% for the mouse device, movement times twice as large as for a mouse device and high overall effort ratings, the Leap Motion Controller's performance as an input device for everyday generic computer pointing tasks is rather limited, at least with regard to the selection recognition provided by the LMC.
Evaluation of the Leap Motion Controller as a New Contact-Free Pointing Device
Bachmann, Daniel; Weichert, Frank; Rinkenauer, Gerhard
2015-01-01
This paper presents a Fitts' law-based analysis of the user's performance in selection tasks with the Leap Motion Controller compared with a standard mouse device. The Leap Motion Controller (LMC) is a new contact-free input system for gesture-based human-computer interaction with declared sub-millimeter accuracy. Up to this point, there has hardly been any systematic evaluation of this new system available. With an error rate of 7.8 % for the LMC and 2.8% for the mouse device, movement times twice as large as for a mouse device and high overall effort ratings, the Leap Motion Controller's performance as an input device for everyday generic computer pointing tasks is rather limited, at least with regard to the selection recognition provided by the LMC. PMID:25609043
System and method for controlling remote devices
Carrender, Curtis Lee [Richland, WA; Gilbert, Ronald W [Benton City, WA; Scott, Jeff W [Pasco, WA; Clark, David A [Kennewick, WA
2006-02-07
A system and method for controlling remote devices utilizing a radio frequency identification (RFID) tag device having a control circuit adapted to render the tag device, and associated objects, permanently inoperable in response to radio-frequency control signals. The control circuit is configured to receive the control signals that can include an enable signal, and in response thereto enable an associated object, such as a weapon; and in response to a disable signal, to disable the tag itself, or, if desired, to disable the associated weapon or both the device and the weapon. Permanent disabling of the tag can be accomplished by several methods, including, but not limited to, fusing a fusable link, breaking an electrically conductive path, permanently altering the modulation or backscattering characteristics of the antenna circuit, and permanently erasing an associated memory. In this manner, tags in the possession of unauthorized employees can be remotely disabled, and weapons lost on a battlefield can be easily tracked and enabled or disabled automatically or at will.
Code of Federal Regulations, 2013 CFR
2013-07-01
... contain, capture and transport a pollutant to a control device. Continuous compliance determination method..., boilers or process heaters). For purposes of this part, a control device does not include passive control...
Motorized CPM/CAM physiotherapy device with sliding-mode Fuzzy Neural Network control loop.
Ho, Hung-Jung; Chen, Tien-Chi
2009-11-01
Continuous passive motion (CPM) and controllable active motion (CAM) physiotherapy devices promote rehabilitation of damaged joints. This paper presents a computerized CPM/CAM system that obviates the need for mechanical resistance devices such as springs. The system is controlled by a computer which performs sliding-mode Fuzzy Neural Network (FNN) calculations online. CAM-type resistance force is generated by the active performance of an electric motor which is controlled so as to oppose the motion of the patient's leg. A force sensor under the patient's foot on the device pedal provides data for feedback in a sliding-mode FNN control loop built around the motor. Via an active impedance control feedback system, the controller drives the motor to behave similarly to a damped spring by generating and controlling the amplitude and direction of the pedal force in relation to the patient's leg. Experiments demonstrate the high sensitivity and speed of the device. The PC-based feedback nature of the control loop means that sophisticated auto-adaptable CPM/CAM custom-designed physiotherapy becomes possible. The computer base also allows extensive data recording, data analysis and network-connected remote patient monitoring.
NASA Technical Reports Server (NTRS)
Crawford, Gregory P.; Li, Liuliu
2005-01-01
Some improvements have been made in the formulation of holographically formed polymer-dispersed liquid crystals (H-PDLCs) and in the fabrication of devices made from these materials, with resulting improvements in performance. H-PDLCs are essentially volume Bragg gratings. Devices made from H-PDLCs function as electrically switchable reflective filters. Heretofore, it has been necessary to apply undesirably high drive voltages in order to switch H-PDLC devices. Many scientific papers on H-PDLCs and on the potential utility of H-PDLC devices for display and telecommunication applications have been published. However, until now, little has been published about improving quality control in synthesis of H-PDLCs and fabrication of H-PDLC devices to minimize (1) spatial nonuniformities within individual devices, (2) nonuniformities among nominally identical devices, and (3) variations in performance among nominally identical devices. The improvements reported here are results of a research effort directed partly toward solving these quality-control problems and partly toward reducing switching voltages. The quality-control improvements include incorporation of a number of process controls to create a relatively robust process, such that the H-PDLC devices fabricated in this process are more nearly uniform than were those fabricated in a prior laboratory-type process. The improved process includes ultrasonic mixing, ultrasonic cleaning, the use of a micro dispensing technique, and the use of a bubble press.
Code of Federal Regulations, 2013 CFR
2013-07-01
... system and add-on control device operating limits during the performance test? 63.4767 Section 63.4767... system and add-on control device operating limits during the performance test? During the performance... operating limits required by § 63.4692 according to this section, unless you have received approval for...
Code of Federal Regulations, 2010 CFR
2010-07-01
... capture system and add-on control device operating limits during the performance test? 63.9324 Section 63... Requirements § 63.9324 How do I establish the emission capture system and add-on control device operating... the operating limits required by § 63.9302 according to this section, unless you have received...
Code of Federal Regulations, 2010 CFR
2010-07-01
... system and add-on control device operating limits during the performance test? 63.3967 Section 63.3967... capture system and add-on control device operating limits during the performance test? During the... the operating limits required by § 63.3892 according to this section, unless you have received...
Code of Federal Regulations, 2011 CFR
2011-07-01
... system and add-on control device operating limits during the performance test? 63.3967 Section 63.3967... capture system and add-on control device operating limits during the performance test? During the... the operating limits required by § 63.3892 according to this section, unless you have received...
Code of Federal Regulations, 2012 CFR
2012-07-01
... capture system and add-on control device operating limits during the performance test? 63.9324 Section 63... Requirements § 63.9324 How do I establish the emission capture system and add-on control device operating... the operating limits required by § 63.9302 according to this section, unless you have received...
Code of Federal Regulations, 2013 CFR
2013-07-01
... system and add-on control device operating limits during the performance test? 63.3967 Section 63.3967... emission capture system and add-on control device operating limits during the performance test? During the... the operating limits required by § 63.3892 according to this section, unless you have received...
Code of Federal Regulations, 2012 CFR
2012-07-01
... capture system and add-on control device operating limits during the performance test? 63.4167 Section 63... capture system and add-on control device operating limits during the performance test? During the... the operating limits required by § 63.4092 according to this section unless you have received approval...
Code of Federal Regulations, 2013 CFR
2013-07-01
... capture system and add-on control device operating limits during the performance test? 63.9324 Section 63... Requirements § 63.9324 How do I establish the emission capture system and add-on control device operating... the operating limits required by § 63.9302 according to this section, unless you have received...
Code of Federal Regulations, 2014 CFR
2014-07-01
... capture system and add-on control device operating limits during the performance test? 63.9324 Section 63... Requirements § 63.9324 How do I establish the emission capture system and add-on control device operating... the operating limits required by § 63.9302 according to this section, unless you have received...
Code of Federal Regulations, 2014 CFR
2014-07-01
... capture system and add-on control device operating limits during the performance test? 63.4567 Section 63... emission capture system and add-on control device operating limits during the performance test? During the... the operating limits required by § 63.4492 according to this section, unless you have received...
Code of Federal Regulations, 2014 CFR
2014-07-01
... capture system and add-on control device operating limits during the performance test? 63.3967 Section 63... establish the emission capture system and add-on control device operating limits during the performance test... must establish the operating limits required by § 63.3892 according to this section, unless you have...
Code of Federal Regulations, 2011 CFR
2011-07-01
... capture system and add-on control device operating limits during the performance test? 63.9324 Section 63... Requirements § 63.9324 How do I establish the emission capture system and add-on control device operating... the operating limits required by § 63.9302 according to this section, unless you have received...
Code of Federal Regulations, 2014 CFR
2014-07-01
... capture system and add-on control device operating limits during the performance test? 63.4167 Section 63... capture system and add-on control device operating limits during the performance test? During the... the operating limits required by § 63.4092 according to this section unless you have received approval...
Code of Federal Regulations, 2014 CFR
2014-07-01
... capture system and add-on control device operating limits during the performance test? 63.4767 Section 63... capture system and add-on control device operating limits during the performance test? During the... the operating limits required by § 63.4692 according to this section, unless you have received...
Code of Federal Regulations, 2012 CFR
2012-07-01
... capture system and add-on control device operating limits during the performance test? 63.4767 Section 63... capture system and add-on control device operating limits during the performance test? During the... the operating limits required by § 63.4692 according to this section, unless you have received...
Code of Federal Regulations, 2012 CFR
2012-07-01
... capture system and add-on control device operating limits during the performance test? 63.3967 Section 63... establish the emission capture system and add-on control device operating limits during the performance test... must establish the operating limits required by § 63.3892 according to this section, unless you have...
Code of Federal Regulations, 2012 CFR
2012-07-01
... capture system and add-on control device operating limits during the performance test? 63.4567 Section 63... emission capture system and add-on control device operating limits during the performance test? During the... the operating limits required by § 63.4492 according to this section, unless you have received...
Code of Federal Regulations, 2013 CFR
2013-07-01
... system and add-on control device operating limits during the performance test? 63.4567 Section 63.4567... capture system and add-on control device operating limits during the performance test? During the... the operating limits required by § 63.4492 according to this section, unless you have received...
Code of Federal Regulations, 2011 CFR
2011-07-01
... pollution control device inspections and make any necessary repairs? 60.4895 Section 60.4895 Protection of... Compliance Requirements § 60.4895 By what date must I conduct annual air pollution control device inspections and make any necessary repairs? (a) You must conduct an annual inspection of each air pollution...
40 CFR 63.5180 - What reports must I submit?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 63.9(e) if you are complying with the emission standard using a control device. This notification and... specified in § 63.10(d)(2) if you are using a control device to comply with the emission standards and you..., shutdown, and malfunction reports as specified in § 63.10(d)(5) if you use a control device to comply with...
Kaufman, H.B.; Weiss, A.A.
1959-08-18
A shadow control device for controlling a nuclear reactor is described. The device comprises a series of hollow neutron-absorbing elements arranged in groups, each element having a cavity for substantially housing an adjoining element and a longitudinal member for commonly supporting the groups of elements. Longitudinal actuation of the longitudinal member distributes the elements along its entire length in which position maximum worth is achieved.
Stackable Form-Factor Peripheral Component Interconnect Device and Assembly
NASA Technical Reports Server (NTRS)
Somervill, Kevin M. (Inventor); Ng, Tak-kwong (Inventor); Torres-Pomales, Wilfredo (Inventor); Malekpour, Mahyar R. (Inventor)
2013-01-01
A stackable form-factor Peripheral Component Interconnect (PCI) device can be configured as a host controller or a master/target for use on a PCI assembly. PCI device may comprise a multiple-input switch coupled to a PCI bus, a multiplexor coupled to the switch, and a reconfigurable device coupled to one of the switch and multiplexor. The PCI device is configured to support functionality from power-up, and either control function or add-in card function.
Laser Ignition Device and Its Application to Forestry, Fire and Land Management
Michael D. Waterworth
1987-01-01
A laser ignition device for controlled burning of forest logging slash has been developed and successfully tested. The device, which uses a kilowatt class carbon dioxide laser, operates at distances of 50 to 1500 meters. Acquisition and focus control are achieved by the use of a laser rangefinder and acquisition telescope. Additional uses for the device include back...
40 CFR 63.10692 - What definitions apply to this subpart?
Code of Federal Regulations, 2011 CFR
2011-07-01
... argon-oxygen decarburization vessel to the air pollution control device. Chlorinated plastics means...) and PVC copolymers. Control device means the air pollution control equipment used to remove...
40 CFR 63.10692 - What definitions apply to this subpart?
Code of Federal Regulations, 2010 CFR
2010-07-01
... argon-oxygen decarburization vessel to the air pollution control device. Chlorinated plastics means...) and PVC copolymers. Control device means the air pollution control equipment used to remove...
Hannan, Mahammad A.; Hussein, Hussein A.; Mutashar, Saad; Samad, Salina A.; Hussain, Aini
2014-01-01
With the development of communication technologies, the use of wireless systems in biomedical implanted devices has become very useful. Bio-implantable devices are electronic devices which are used for treatment and monitoring brain implants, pacemakers, cochlear implants, retinal implants and so on. The inductive coupling link is used to transmit power and data between the primary and secondary sides of the biomedical implanted system, in which efficient power amplifier is very much needed to ensure the best data transmission rates and low power losses. However, the efficiency of the implanted devices depends on the circuit design, controller, load variation, changes of radio frequency coil's mutual displacement and coupling coefficients. This paper provides a comprehensive survey on various power amplifier classes and their characteristics, efficiency and controller techniques that have been used in bio-implants. The automatic frequency controller used in biomedical implants such as gate drive switching control, closed loop power control, voltage controlled oscillator, capacitor control and microcontroller frequency control have been explained. Most of these techniques keep the resonance frequency stable in transcutaneous power transfer between the external coil and the coil implanted inside the body. Detailed information including carrier frequency, power efficiency, coils displacement, power consumption, supplied voltage and CMOS chip for the controllers techniques are investigated and summarized in the provided tables. From the rigorous review, it is observed that the existing automatic frequency controller technologies are more or less can capable of performing well in the implant devices; however, the systems are still not up to the mark. Accordingly, current challenges and problems of the typical automatic frequency controller techniques for power amplifiers are illustrated, with a brief suggestions and discussion section concerning the progress of implanted device research in the future. This review will hopefully lead to increasing efforts towards the development of low powered, highly efficient, high data rate and reliable automatic frequency controllers for implanted devices. PMID:25615728
Recent developments in drug eluting devices with tailored interfacial properties.
Sanchez-Rexach, Eva; Meaurio, Emilio; Sarasua, Jose-Ramon
2017-11-01
Drug eluting devices have greatly evolved during past years to become fundamental products of great marketing importance in the biomedical field. There is currently a large diversity of highly specialized devices for specific applications, making the development of these devices an exciting field of research. The replacement of the former bare metal devices by devices loaded with drugs allowed the sustained and controlled release of drugs, to achieve the desired local therapeutic concentration of drug. The newer devices have been "engineered" with surfaces containing micro- and nanoscale features in a well-controlled manner, that have shown to significantly affect cellular and subcellular function of various biological systems. For example, the topography can be structured to form an antifouling surface mimicking the defense mechanisms found in nature, like the skin of the shark. In the case of bone implants, well-controlled nanostructured interfaces can promote osteoblast differentiation and matrix production, and enhance short-term and long-term osteointegration. In any case, the goal of current research is to design implants that induce controlled, guided, and rapid healing. This article reviews recent trends in the development of drug eluting devices, as well as recent developments on the micro/nanotechnology scales, and their future challenges. For this purpose medical devices have been divided according to the different systems of the body they are focused to: orthopedic devices, breathing stents, gastrointestinal and urinary systems, devices for cardiovascular diseases, neuronal implants, and wound dressings. Copyright © 2017 Elsevier B.V. All rights reserved.
40 CFR 1037.801 - Definitions.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... Auxiliary emission control device means any element of design that senses temperature, motive speed, engine... any device, system, or element of design that controls or reduces the emissions of regulated... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF...
40 CFR 1037.801 - Definitions.
Code of Federal Regulations, 2014 CFR
2014-07-01
.... Auxiliary emission control device means any element of design that senses temperature, motive speed, engine... any device, system, or element of design that controls or reduces the emissions of regulated... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF...
NASA Technical Reports Server (NTRS)
Leung, P. S.; Craighead, I. A.; Wilkinson, T. S.
1991-01-01
The development of a new device to control stability of turbogenerators is described. The device comprises a floating ring installed between the journal and bearing housing of a fluid film bearing. The journal and the inner surface of the ring are cylindrical while the outer surface of the ring and bearing surface are spherical providing axial location of the ring and self-alignment of the bearing. The employment of this device would lead to a consistent machine performance. System stability may be controlled by changing a number of bearing and floating ring parameters. This device also offers an additional advantage of having a very low frictional characteristic. A feasibility study was carried out to investigate the suitability of the new device to turbogenerator applications. Both theoretical analysis and experimental observations were carried out. Initial results suggest that the new floating ring device is a competitive alternative to other conventional arrangements.
A dual channel three-terminal np-LDMOS with both majorities for conduction
NASA Astrophysics Data System (ADS)
Kong, Moufu; Yi, Bo; Zhang, Bingke
2018-02-01
A novel dual channel three-terminal np-LDMOS power device with both electrons and holes for conduction is proposed in this paper. Based on a new approach of inducing a large-signal which is processed by a simple circuit for controlling the gate of p-LDMOS inside the device, the new np-LDMOS only requires one external gate controlling voltage signal that can be performed as an n-LDMOS device. The SOA of the new device is improved in comparison with the n-LDMOS device, since the counteracting of electric flux density produced by the both type of carriers' currents. Furthermore, the specific on-resistance of the np-LDMOS device is reduced by about 19% when comparing with that of the conventional one. The control method and performances of the proposed power device are investigated and authenticated by numerical simulations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krempasky, J.; Flechsig, U.; Korhonen, T.
Synchronous monochromator and insertion device energy scans were implemented at the Surfaces/Interfaces:Microscopy (SIM) beamline in order to provide the users fast X-ray magnetic dichroism studies (XMCD). A simple software control scheme is proposed based on a fast monochromator run-time energy readback which quickly updates the insertion device requested energy during an on-the-fly X-ray absorption scan (XAS). In this scheme the Plain Grating Monochromator (PGM) motion control, being much slower compared with the insertion device (APPLE-II type undulator), acts as a 'master' controlling the undulator 'slave' energy position. This master-slave software implementation exploits EPICS distributed device control over computer network andmore » allows for a quasi-synchronous motion control combined with data acquisition needed for the XAS or XMCD experiment.« less
Effects of Device on Video Head Impulse Test (vHIT) Gain.
Janky, Kristen L; Patterson, Jessie N; Shepard, Neil T; Thomas, Megan L A; Honaker, Julie A
2017-10-01
Numerous video head impulse test (vHIT) devices are available commercially; however, gain is not calculated uniformly. An evaluation of these devices/algorithms in healthy controls and patients with vestibular loss is necessary for comparing and synthesizing work that utilizes different devices and gain calculations. Using three commercially available vHIT devices/algorithms, the purpose of the present study was to compare: (1) horizontal canal vHIT gain among devices/algorithms in normal control subjects; (2) the effects of age on vHIT gain for each device/algorithm in normal control subjects; and (3) the clinical performance of horizontal canal vHIT gain between devices/algorithms for differentiating normal versus abnormal vestibular function. Prospective. Sixty-one normal control adult subjects (range 20-78) and eleven adults with unilateral or bilateral vestibular loss (range 32-79). vHIT was administered using three different devices/algorithms, randomized in order, for each subject on the same day: (1) Impulse (Otometrics, Schaumberg, IL; monocular eye recording, right eye only; using area under the curve gain), (2) EyeSeeCam (Interacoustics, Denmark; monocular eye recording, left eye only; using instantaneous gain), and (3) VisualEyes (MicroMedical, Chatham, IL, binocular eye recording; using position gain). There was a significant mean difference in vHIT gain among devices/algorithms for both the normal control and vestibular loss groups. vHIT gain was significantly larger in the ipsilateral direction of the eye used to measure gain; however, in spite of the significant mean differences in vHIT gain among devices/algorithms and the significant directional bias, classification of "normal" versus "abnormal" gain is consistent across all compared devices/algorithms, with the exception of instantaneous gain at 40 msec. There was not an effect of age on vHIT gain up to 78 years regardless of the device/algorithm. These findings support that vHIT gain is significantly different between devices/algorithms, suggesting that care should be taken when making direct comparisons of absolute gain values between devices/algorithms. American Academy of Audiology
Dichroic beamsplitter for high energy laser diagnostics
LaFortune, Kai N [Livermore, CA; Hurd, Randall [Tracy, CA; Fochs, Scott N [Livermore, CA; Rotter, Mark D [San Ramon, CA; Hackel, Lloyd [Livermore, CA
2011-08-30
Wavefront control techniques are provided for the alignment and performance optimization of optical devices. A Shack-Hartmann wavefront sensor can be used to measure the wavefront distortion and a control system generates feedback error signal to optics inside the device to correct the wavefront. The system can be calibrated with a low-average-power probe laser. An optical element is provided to couple the optical device to a diagnostic/control package in a way that optimizes both the output power of the optical device and the coupling of the probe light into the diagnostics.
Variable pressure thermal insulating jacket
Nelson, P.A.; Malecha, R.F.; Chilenskas, A.A.
1994-09-20
A device for controlled insulation of a thermal device is disclosed. The device includes a thermal jacket with a closed volume able to be evacuated to form an insulating jacket around the thermal source. A getter material is in communication with the closed volume of the thermal jacket. The getter material can absorb and desorb a control gas to control gas pressure in the volume of the thermal jacket to control thermal conductivity in the thermal jacket. 10 figs.
Development and control of a magnetorheological haptic device for robot assisted surgery.
Shokrollahi, Elnaz; Goldenberg, Andrew A; Drake, James M; Eastwood, Kyle W; Kang, Matthew
2017-07-01
A prototype magnetorheological (MR) fluid-based actuator has been designed for tele-robotic surgical applications. This device is capable of generating forces up to 47 N, with input currents ranging from 0 to 1.5 A. We begin by outlining the physical design of the device, and then discuss a novel nonlinear model of the device's behavior. The model was developed using the Hammerstein-Wiener (H-W) nonlinear black-box technique and is intended to accurately capture the hysteresis behavior of the MR-fluid. Several experiments were conducted on the device to collect estimation and validation datasets to construct the model and assess its performance. Different estimating functions were used to construct the model, and their effectiveness is assessed based on goodness-of-fit and final-prediction-error measurements. A sigmoid network was found to have a goodness-of-fit of 95%. The model estimate was then used to tune a PID controller. Two control schemes were proposed to eliminate the hysteresis behavior present in the MR fluid device. One method uses a traditional force feedback control loop and the other is based on measuring the magnetic field using a Hall-effect sensor embedded within the device. The Hall-effect sensor scheme was found to be superior in terms of cost, simplicity and real-time control performance compared to the force control strategy.
21 CFR 872.1745 - Laser fluorescence caries detection device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1745 Laser fluorescence caries... fluorescence detector housed in a dental handpiece, and a control console that performs device calibration, as...
21 CFR 872.1745 - Laser fluorescence caries detection device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1745 Laser fluorescence caries... fluorescence detector housed in a dental handpiece, and a control console that performs device calibration, as...
40 CFR 1039.801 - What definitions apply to this part?
Code of Federal Regulations, 2014 CFR
2014-07-01
... operation in water. Auxiliary emission-control device means any element of design that senses temperature... suppression operations. Emission-control system means any device, system, or element of design that controls... POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Definitions...
49 CFR 236.771 - Machine, control.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Machine, control. 236.771 Section 236.771..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.771 Machine, control. An assemblage of manually operated devices for controlling the functions of a traffic...
49 CFR 236.771 - Machine, control.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 4 2013-10-01 2013-10-01 false Machine, control. 236.771 Section 236.771..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.771 Machine, control. An assemblage of manually operated devices for controlling the functions of a traffic...
49 CFR 236.771 - Machine, control.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Machine, control. 236.771 Section 236.771..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.771 Machine, control. An assemblage of manually operated devices for controlling the functions of a traffic...
49 CFR 236.771 - Machine, control.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 4 2014-10-01 2014-10-01 false Machine, control. 236.771 Section 236.771..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.771 Machine, control. An assemblage of manually operated devices for controlling the functions of a traffic...
Thermoelectric device for treatment of radiculitis and spinal massage
NASA Astrophysics Data System (ADS)
Anatychuk, L. I.; Kobylyansky, R. R.
2012-06-01
Results of development of a thermoelectric device that enables controlled cyclic temperature impact on the damaged area of human organism are presented. Unlike the existing medical devices employing direct supply current for thermoelectric module, the present device controls supply current according to time dependence of temperature change assigned by doctor. It is established that such a device is an efficient means of therapy at herniation of intervertebral disks with marked radiculitis and tunicary syndromes, at meningitis, other spinal diseases and back traumas.
2014-09-03
The Food and Drug Administration (FDA) is classifying early growth response 1 (EGR1) gene fluorescence in-situ hybridization (FISH) test system for specimen characterization into class II (special controls). The special controls that will apply to this device are identified in this order and will be part of the codified language for the early growth response 1 (EGR1) gene fluorescence in-site hybridization (FISH) test system for specimen characterization classification. The Agency is classifying the device into class II (special controls) in order to provide a reasonable assurance of safety and effectiveness of the device.
2002-12-01
An operating room (OR) automation system is a combination of hardware and software designed to address efficiency issues in the OR by controling multiple devices via a common interface. Systems range from the relatively basic--allowing control of a few devices within a single OR--to advanced designs that are capable of not only controlling a wide range of devices within the OR but also exchanging information with remote locations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... to Subpart OOOO of Part 63—Operating Limits if Using Add-On Control Devices and Capture System If you... 40 Protection of Environment 13 2014-07-01 2014-07-01 false Operating Limits if Using Add-On Control Devices and Capture System 2 Table 2 to Subpart OOOO of Part 63 Protection of Environment...
Code of Federal Regulations, 2014 CFR
2014-07-01
...—Operating Limits if Using Add-On Control Devices and Capture System If you are required to comply with... 40 Protection of Environment 13 2014-07-01 2014-07-01 false Operating Limits if Using Add-On Control Devices and Capture System 1 Table 1 to Subpart JJJJ of Part 63 Protection of Environment...
Code of Federal Regulations, 2014 CFR
2014-07-01
...—Operating Limits if Using Add-on Control Devices and Capture System If you are required to comply with... 40 Protection of Environment 13 2014-07-01 2014-07-01 false Operating Limits if Using Add-on Control Devices and Capture System 1 Table 1 to Subpart SSSS of Part 63 Protection of Environment...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Limits if Using Add-On Control Devices and Capture System If you are required to comply with operating... 40 Protection of Environment 12 2011-07-01 2009-07-01 true Operating Limits if Using Add-On Control Devices and Capture System 1 Table 1 to Subpart JJJJ of Part 63 Protection of Environment...
Code of Federal Regulations, 2012 CFR
2012-07-01
...—Operating Limits if Using Add-On Control Devices and Capture System If you are required to comply with... 40 Protection of Environment 13 2012-07-01 2012-07-01 false Operating Limits if Using Add-On Control Devices and Capture System 1 Table 1 to Subpart JJJJ of Part 63 Protection of Environment...
Code of Federal Regulations, 2013 CFR
2013-07-01
... to Subpart OOOO of Part 63—Operating Limits if Using Add-On Control Devices and Capture System If you... 40 Protection of Environment 13 2013-07-01 2012-07-01 true Operating Limits if Using Add-On Control Devices and Capture System 2 Table 2 to Subpart OOOO of Part 63 Protection of Environment...
Code of Federal Regulations, 2013 CFR
2013-07-01
...—Operating Limits if Using Add-on Control Devices and Capture System If you are required to comply with... 40 Protection of Environment 13 2013-07-01 2012-07-01 true Operating Limits if Using Add-on Control Devices and Capture System 1 Table 1 to Subpart SSSS of Part 63 Protection of Environment...
Code of Federal Regulations, 2012 CFR
2012-07-01
... to Subpart OOOO of Part 63—Operating Limits if Using Add-On Control Devices and Capture System If you... 40 Protection of Environment 13 2012-07-01 2012-07-01 false Operating Limits if Using Add-On Control Devices and Capture System 2 Table 2 to Subpart OOOO of Part 63 Protection of Environment...
Code of Federal Regulations, 2010 CFR
2010-07-01
... OOOO of Part 63—Operating Limits if Using Add-On Control Devices and Capture System If you are required... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Operating Limits if Using Add-On Control Devices and Capture System 2 Table 2 to Subpart OOOO of Part 63 Protection of Environment...
Code of Federal Regulations, 2012 CFR
2012-07-01
...—Operating Limits if Using Add-on Control Devices and Capture System If you are required to comply with... 40 Protection of Environment 13 2012-07-01 2012-07-01 false Operating Limits if Using Add-on Control Devices and Capture System 1 Table 1 to Subpart SSSS of Part 63 Protection of Environment...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Using Add-on Control Devices and Capture System If you are required to comply with operating limits by... 40 Protection of Environment 12 2011-07-01 2009-07-01 true Operating Limits if Using Add-on Control Devices and Capture System 1 Table 1 to Subpart SSSS of Part 63 Protection of Environment...
Code of Federal Regulations, 2011 CFR
2011-07-01
... OOOO of Part 63—Operating Limits if Using Add-On Control Devices and Capture System If you are required... 40 Protection of Environment 12 2011-07-01 2009-07-01 true Operating Limits if Using Add-On Control Devices and Capture System 2 Table 2 to Subpart OOOO of Part 63 Protection of Environment...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Using Add-on Control Devices and Capture System If you are required to comply with operating limits by... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Operating Limits if Using Add-on Control Devices and Capture System 1 Table 1 to Subpart SSSS of Part 63 Protection of Environment...
Code of Federal Regulations, 2013 CFR
2013-07-01
...—Operating Limits if Using Add-On Control Devices and Capture System If you are required to comply with... 40 Protection of Environment 13 2013-07-01 2012-07-01 true Operating Limits if Using Add-On Control Devices and Capture System 1 Table 1 to Subpart JJJJ of Part 63 Protection of Environment...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Limits if Using Add-On Control Devices and Capture System If you are required to comply with operating... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Operating Limits if Using Add-On Control Devices and Capture System 1 Table 1 to Subpart JJJJ of Part 63 Protection of Environment...
Code of Federal Regulations, 2014 CFR
2014-07-01
... percent oxygen as determined in accordance with the requirements of § 60.5413. (iii) You must operate at a... requirements of § 60.5415(b)(2), as applicable. (c) For each carbon adsorption system used as a control device... (a)(1) through (3) of this section. As an alternative, you may install a control device model tested...
21 CFR 862.1660 - Quality control material (assayed and unassayed).
Code of Federal Regulations, 2013 CFR
2013-04-01
... SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry... control material (assayed and unassayed) for clinical chemistry is a device intended for medical purposes for use in a test system to estimate test precision and to detect systematic analytical deviations...
21 CFR 862.1660 - Quality control material (assayed and unassayed).
Code of Federal Regulations, 2014 CFR
2014-04-01
... SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry... control material (assayed and unassayed) for clinical chemistry is a device intended for medical purposes for use in a test system to estimate test precision and to detect systematic analytical deviations...
21 CFR 862.1660 - Quality control material (assayed and unassayed).
Code of Federal Regulations, 2012 CFR
2012-04-01
... SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry... control material (assayed and unassayed) for clinical chemistry is a device intended for medical purposes for use in a test system to estimate test precision and to detect systematic analytical deviations...
Fast, high sensitivity dewpoint hygrometer
NASA Technical Reports Server (NTRS)
Hoenk, Michael E. (Inventor)
1998-01-01
A dewpoint/frostpoint hygrometer that uses a surface moisture-sensitive sensor as part of an RF oscillator circuit with feedback control of the sensor temperature to maintain equilibrium at the sensor surface between ambient water vapor and condensed water/ice. The invention is preferably implemented using a surface acoustic wave (SAW) device in an RF oscillator circuit configured to generate a condensation-dependent output signal, a temperature sensor to measure the temperature of the SAW device and to distinguish between condensation-dependent and temperature-dependent signals, a temperature regulating device to control the temperature of the SAW device, and a feedback control system configured to keep the condensation-dependent signal nearly constant over time in the presence of time-varying humidity, corrected for temperature. The effect of this response is to heat or cool the surface moisture-sensitive device, which shifts the equilibrium with respect to evaporation and condensation at the surface of the device. The equilibrium temperature under feedback control is a measure of dewpoint or frostpoint.
21 CFR 874.5550 - Powered nasal irrigator.
Code of Federal Regulations, 2011 CFR
2011-04-01
... pressure-controlled pulsating stream of water. The device consists of a control unit and pump connected to a spray tube and nozzle. (b) Classification. Class I (general controls). The device is exempt from...
21 CFR 874.5550 - Powered nasal irrigator.
Code of Federal Regulations, 2012 CFR
2012-04-01
... pressure-controlled pulsating stream of water. The device consists of a control unit and pump connected to a spray tube and nozzle. (b) Classification. Class I (general controls). The device is exempt from...
21 CFR 874.5550 - Powered nasal irrigator.
Code of Federal Regulations, 2013 CFR
2013-04-01
... pressure-controlled pulsating stream of water. The device consists of a control unit and pump connected to a spray tube and nozzle. (b) Classification. Class I (general controls). The device is exempt from...
21 CFR 874.5550 - Powered nasal irrigator.
Code of Federal Regulations, 2014 CFR
2014-04-01
... pressure-controlled pulsating stream of water. The device consists of a control unit and pump connected to a spray tube and nozzle. (b) Classification. Class I (general controls). The device is exempt from...
21 CFR 874.5550 - Powered nasal irrigator.
Code of Federal Regulations, 2010 CFR
2010-04-01
... pressure-controlled pulsating stream of water. The device consists of a control unit and pump connected to a spray tube and nozzle. (b) Classification. Class I (general controls). The device is exempt from...
Fast-acting nuclear reactor control device
Kotlyar, Oleg M.; West, Phillip B.
1993-01-01
A fast-acting nuclear reactor control device for moving and positioning a fety control rod to desired positions within the core of the reactor between a run position in which the safety control rod is outside the reactor core, and a shutdown position in which the rod is fully inserted in the reactor core. The device employs a hydraulic pump/motor, an electric gear motor, and solenoid valve to drive the safety control rod into the reactor core through the entire stroke of the safety control rod. An overrunning clutch allows the safety control rod to freely travel toward a safe position in the event of a partial drive system failure.
40 CFR 63.749 - Compliance dates and determinations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... control system efficiency, Ek, as determined using the procedures specified in § 63.750(g) for control systems containing carbon adsorbers and in § 63.750(h) for control systems with other control devices, is... device is used, (A) The overall control system efficiency, Ek, as determined using the procedures...
40 CFR 63.749 - Compliance dates and determinations.
Code of Federal Regulations, 2013 CFR
2013-07-01
... control system efficiency, Ek, as determined using the procedures specified in § 63.750(g) for control systems containing carbon adsorbers and in § 63.750(h) for control systems with other control devices, is... device is used, (A) The overall control system efficiency, Ek, as determined using the procedures...
40 CFR 63.749 - Compliance dates and determinations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... control system efficiency, Ek, as determined using the procedures specified in § 63.750(g) for control systems containing carbon adsorbers and in § 63.750(h) for control systems with other control devices, is... device is used, (A) The overall control system efficiency, Ek, as determined using the procedures...
40 CFR 63.749 - Compliance dates and determinations.
Code of Federal Regulations, 2012 CFR
2012-07-01
... control system efficiency, Ek, as determined using the procedures specified in § 63.750(g) for control systems containing carbon adsorbers and in § 63.750(h) for control systems with other control devices, is... device is used, (A) The overall control system efficiency, Ek, as determined using the procedures...
40 CFR 63.749 - Compliance dates and determinations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... control system efficiency, Ek, as determined using the procedures specified in § 63.750(g) for control systems containing carbon adsorbers and in § 63.750(h) for control systems with other control devices, is... device is used, (A) The overall control system efficiency, Ek, as determined using the procedures...
Electric control of superconducting transition through a spin-orbit coupled interface
Ouassou, Jabir Ali; Di Bernardo, Angelo; Robinson, Jason W. A.; Linder, Jacob
2016-01-01
We demonstrate theoretically all-electric control of the superconducting transition temperature using a device comprised of a conventional superconductor, a ferromagnetic insulator, and semiconducting layers with intrinsic spin-orbit coupling. By using analytical calculations and numerical simulations, we show that the transition temperature of such a device can be controlled by electric gating which alters the ratio of Rashba to Dresselhaus spin-orbit coupling. The results offer a new pathway to control superconductivity in spintronic devices. PMID:27426887
Graham, R.H.
1962-09-01
A wholly mechanical compact control device is designed for automatically rendering the core of a fission reactor subcritical in response to core temperatures in excess of the design operating temperature limit. The control device comprises an expansible bellows interposed between the base of a channel in a reactor core and the inner end of a fuel cylinder therein which is normally resiliently urged inwardly. The bellows contains a working fluid which undergoes a liquid to vapor phase change at a temperature substantially equal to the design temperature limit. Hence, the bellows abruptiy expands at this limiting temperature to force the fuel cylinder outward and render the core subcritical. The control device is particularly applicable to aircraft propulsion reactor service. (AEC)
21 CFR 870.1290 - Steerable catheter control system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Steerable catheter control system. 870.1290 Section 870.1290 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1290 Steerable...
21 CFR 870.1290 - Steerable catheter control system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Steerable catheter control system. 870.1290 Section 870.1290 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1290 Steerable...
Experimental and simulated control of lift using trailing edge devices
NASA Astrophysics Data System (ADS)
Cooperman, A.; Blaylock, M.; van Dam, C. P.
2014-12-01
Two active aerodynamic load control (AALC) devices coupled with a control algorithm are shown to decrease the change in lift force experienced by an airfoil during a change in freestream velocity. Microtabs are small (1% chord) surfaces deployed perpendicular to an airfoil, while microjets are pneumatic jets with flow perpendicular to the surface of the airfoil near the trailing edge. Both devices are capable of producing a rapid change in an airfoil's lift coefficient. A control algorithm for microtabs has been tested in a wind tunnel using a modified S819 airfoil, and a microjet control algorithm has been simulated for a NACA 0012 airfoil using OVERFLOW. In both cases, the AALC devices have shown the ability to mitigate the changes in lift during a gust.
21 CFR 884.6150 - Assisted reproduction micromanipulators and microinjectors.
Code of Federal Regulations, 2011 CFR
2011-04-01
... controls) (design specifications, labeling requirements, and clinical testing). .... Assisted reproduction micromanipulators are devices intended to control the position of an assisted reproduction microtool. Assisted reproduction microinjectors are any device intended to control aspiration or...
21 CFR 884.6150 - Assisted reproduction micromanipulators and microinjectors.
Code of Federal Regulations, 2013 CFR
2013-04-01
... controls) (design specifications, labeling requirements, and clinical testing). .... Assisted reproduction micromanipulators are devices intended to control the position of an assisted reproduction microtool. Assisted reproduction microinjectors are any device intended to control aspiration or...
21 CFR 884.6150 - Assisted reproduction micromanipulators and microinjectors.
Code of Federal Regulations, 2010 CFR
2010-04-01
... controls) (design specifications, labeling requirements, and clinical testing). .... Assisted reproduction micromanipulators are devices intended to control the position of an assisted reproduction microtool. Assisted reproduction microinjectors are any device intended to control aspiration or...
21 CFR 884.6150 - Assisted reproduction micromanipulators and microinjectors.
Code of Federal Regulations, 2012 CFR
2012-04-01
... controls) (design specifications, labeling requirements, and clinical testing). .... Assisted reproduction micromanipulators are devices intended to control the position of an assisted reproduction microtool. Assisted reproduction microinjectors are any device intended to control aspiration or...
21 CFR 884.6150 - Assisted reproduction micromanipulators and microinjectors.
Code of Federal Regulations, 2014 CFR
2014-04-01
... controls) (design specifications, labeling requirements, and clinical testing). .... Assisted reproduction micromanipulators are devices intended to control the position of an assisted reproduction microtool. Assisted reproduction microinjectors are any device intended to control aspiration or...
An open-source, extensible system for laboratory timing and control
NASA Astrophysics Data System (ADS)
Gaskell, Peter E.; Thorn, Jeremy J.; Alba, Sequoia; Steck, Daniel A.
2009-11-01
We describe a simple system for timing and control, which provides control of analog, digital, and radio-frequency signals. Our system differs from most common laboratory setups in that it is open source, built from off-the-shelf components, synchronized to a common and accurate clock, and connected over an Ethernet network. A simple bus architecture facilitates creating new and specialized devices with only moderate experience in circuit design. Each device operates independently, requiring only an Ethernet network connection to the controlling computer, a clock signal, and a trigger signal. This makes the system highly robust and scalable. The devices can all be connected to a single external clock, allowing synchronous operation of a large number of devices for situations requiring precise timing of many parallel control and acquisition channels. Provided an accurate enough clock, these devices are capable of triggering events separated by one day with near-microsecond precision. We have achieved precisions of ˜0.1 ppb (parts per 109) over 16 s.
Energy storage connection system
Benedict, Eric L.; Borland, Nicholas P.; Dale, Magdelena; Freeman, Belvin; Kite, Kim A.; Petter, Jeffrey K.; Taylor, Brendan F.
2012-07-03
A power system for connecting a variable voltage power source, such as a power controller, with a plurality of energy storage devices, at least two of which have a different initial voltage than the output voltage of the variable voltage power source. The power system includes a controller that increases the output voltage of the variable voltage power source. When such output voltage is substantially equal to the initial voltage of a first one of the energy storage devices, the controller sends a signal that causes a switch to connect the variable voltage power source with the first one of the energy storage devices. The controller then causes the output voltage of the variable voltage power source to continue increasing. When the output voltage is substantially equal to the initial voltage of a second one of the energy storage devices, the controller sends a signal that causes a switch to connect the variable voltage power source with the second one of the energy storage devices.
Myoelectric control of prosthetic hands: state-of-the-art review
Geethanjali, Purushothaman
2016-01-01
Myoelectric signals (MES) have been used in various applications, in particular, for identification of user intention to potentially control assistive devices for amputees, orthotic devices, and exoskeleton in order to augment capability of the user. MES are also used to estimate force and, hence, torque to actuate the assistive device. The application of MES is not limited to assistive devices, and they also find potential applications in teleoperation of robots, haptic devices, virtual reality, and so on. The myoelectric control-based prosthetic hand aids to restore activities of daily living of amputees in order to improve the self-esteem of the user. All myoelectric control-based prosthetic hands may not have similar operations and exhibit variation in sensing input, deciphering the signals, and actuating prosthetic hand. Researchers are focusing on improving the functionality of prosthetic hand in order to suit the user requirement with the different operating features. The myoelectric control differs in operation to accommodate various external factors. This article reviews the state of the art of myoelectric prosthetic hand, giving description of each control strategy. PMID:27555799
Efficient semiconductor light-emitting device and method
Choquette, Kent D.; Lear, Kevin L.; Schneider, Jr., Richard P.
1996-01-01
A semiconductor light-emitting device and method. The semiconductor light-emitting device is provided with at least one control layer or control region which includes an annular oxidized portion thereof to channel an injection current into the active region, and to provide a lateral refractive index profile for index guiding the light generated within the device. A periodic composition grading of at least one of the mirror stacks in the device provides a reduced operating voltage of the device. The semiconductor light-emitting device has a high efficiency for light generation, and may be formed either as a resonant-cavity light-emitting diode (RCLED) or as a vertical-cavity surface-emitting laser (VCSEL).
Efficient semiconductor light-emitting device and method
Choquette, K.D.; Lear, K.L.; Schneider, R.P. Jr.
1996-02-20
A semiconductor light-emitting device and method are disclosed. The semiconductor light-emitting device is provided with at least one control layer or control region which includes an annular oxidized portion thereof to channel an injection current into the active region, and to provide a lateral refractive index profile for index guiding the light generated within the device. A periodic composition grading of at least one of the mirror stacks in the device provides a reduced operating voltage of the device. The semiconductor light-emitting device has a high efficiency for light generation, and may be formed either as a resonant-cavity light-emitting diode (RCLED) or as a vertical-cavity surface-emitting laser (VCSEL). 12 figs.
Application accelerator system having bunch control
Wang, Dunxiong; Krafft, Geoffrey Arthur
1999-01-01
An application accelerator system for monitoring the gain of a free electron laser. Coherent Synchrotron Radiation (CSR) detection techniques are used with a bunch length monitor for ultra short, picosec to several tens of femtosec, electron bunches. The monitor employs an application accelerator, a coherent radiation production device, an optical or beam chopping device, an infrared radiation collection device, a narrow-banding filter, an infrared detection device, and a control.
Liquid crystal photonic bandgap fiber components
NASA Astrophysics Data System (ADS)
Scolari, L.; Alkeskjold, T. T.; Noordegraaf, D.; Tartarini, G.; Bassi, P.; Bjarklev, A.
2007-11-01
Liquid crystal photonic bandgap fibers represent a promising platform for the design of all-in-fiber optical devices, which show a high degree of tunability and exhibit novel optical properties for the manipulation of guided light. In this review paper we present tunable fiber devices for spectral filtering, such as Gaussian filters and notch filters, and devices for polarization control and analysis, such as birefringence control devices and switchable and rotatable polarizers.
Phillips, Reid H; Jain, Rahil; Browning, Yoni; Shah, Rachana; Kauffman, Peter; Dinh, Doan; Lutz, Barry R
2016-08-16
Fluid control remains a challenge in development of portable lab-on-a-chip devices. Here, we show that microfluidic networks driven by single-frequency audio tones create resonant oscillating flow that is predicted by equivalent electrical circuit models. We fabricated microfluidic devices with fluidic resistors (R), inductors (L), and capacitors (C) to create RLC networks with band-pass resonance in the audible frequency range available on portable audio devices. Microfluidic devices were fabricated from laser-cut adhesive plastic, and a "buzzer" was glued to a diaphragm (capacitor) to integrate the actuator on the device. The AC flowrate magnitude was measured by imaging oscillation of bead tracers to allow direct comparison to the RLC circuit model across the frequency range. We present a systematic build-up from single-channel systems to multi-channel (3-channel) networks, and show that RLC circuit models predict complex frequency-dependent interactions within multi-channel networks. Finally, we show that adding flow rectifying valves to the network creates pumps that can be driven by amplified and non-amplified audio tones from common audio devices (iPod and iPhone). This work shows that RLC circuit models predict resonant flow responses in multi-channel fluidic networks as a step towards microfluidic devices controlled by audio tones.
An Automatic Occlusion Device for Remote Control of Tumor Tissue Ischemia
El-Dahdah, Hamid; Wang, Bei; He, Guanglong; Xu, Ronald X.
2015-01-01
We developed an automatic occlusion device for remote control of tumor tissue ischemia. The device consists of a flexible cannula encasing a shape memory alloy wire with its distal end connected to surgical suture. Regional tissue occlusion was tested on both the benchtop and the animal models. In the benchtop test, the occlusion device introduced quantitative and reproducible changes of blood flow in a tissue simulating phantom embedding a vessel simulator. In the animal test, the device generated a cyclic pattern of reversible ischemia in the right hinder leg tissue of a black male C57BL/6 mouse. We also developed a multimodal detector that integrates near infrared spectroscopy and electron paramagnetic resonance spectroscopy for continuous monitoring of tumor tissue oxygenation, blood content, and oxygen tension changes. The multimodal detector was tested on a cancer xenograft nude mouse undergoing reversible tumor ischemia. The automatic occlusion device and the multi-modal detector can be potentially integrated for closed-loop feedback control of tumor tissue ischemia. Such an integrated occlusion device may be used in multiple clinical applications such as regional hypoperfusion control in tumor resection surgeries and thermal ablation processes. In addition, the proposed occlusion device can also be used as a research tool to understand tumor oxygen transport and hemodynamic characteristics. PMID:20082532
2010-10-01
An Empirical Study on Operator Interface Design for Handheld Devices to Control Micro Aerial Vehicles Ming Hou...Report DRDC Toronto TR 2010-075 October 2010 An Empirical Study on Operator Interface Design for Handheld Devices to...drives the need for a small and light controller which will not hinder a soldier carrying it. This requirement brings an issue of designing an
Zhao, Xiaohua; Li, Jiahui; Ma, Jianming; Rong, Jian
2016-01-01
Traffic control devices are one of the most significant factors affecting driving behavior. In China, there is a lack of installation guidelines or standards for traffic control devices in school zones. In addition, little research has been done to examine the effects of traffic control devices on driving behavior. Few guidelines have been established for implementing traffic control devices in school zones in China. This research conducted a driving simulator experiment to assess the effects of school zone signs and markings for two different types of schools. The efficiency of these traffic control devices was evaluated using four variables derived from the driving simulation, including average speed, relative speed difference, standard deviation of acceleration, and 85th percentile speed. Results showed that traffic control devices such as the Flashing Beacon and School Crossing Ahead Warning Assembly, the Reduce Speed and School Crossing Warning Assembly, and the School Crossing Ahead Pavement Markings were recommended for school zones adjacent to a major multilane roadway, which is characterized by a median strip, high traffic volume, high-speed traffic and the presence of pedestrian crossing signals. The School Crossing Ahead Pavement Markings were recommended for school zones on a minor two-lane roadway, which is characterized by low traffic volume, low speed, and no pedestrian crossing signals.
21 CFR 862.3280 - Clinical toxicology control material.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Clinical toxicology control material. 862.3280... (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862.3280 Clinical toxicology control material. (a) Identification. A clinical toxicology control...
21 CFR 862.3280 - Clinical toxicology control material.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Clinical toxicology control material. 862.3280... (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862.3280 Clinical toxicology control material. (a) Identification. A clinical toxicology control...
21 CFR 862.3280 - Clinical toxicology control material.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Clinical toxicology control material. 862.3280... (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862.3280 Clinical toxicology control material. (a) Identification. A clinical toxicology control...
21 CFR 862.3280 - Clinical toxicology control material.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Clinical toxicology control material. 862.3280... (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862.3280 Clinical toxicology control material. (a) Identification. A clinical toxicology control...
21 CFR 862.3280 - Clinical toxicology control material.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Clinical toxicology control material. 862.3280... (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862.3280 Clinical toxicology control material. (a) Identification. A clinical toxicology control...
15 CFR Supplement No. 4 to Part 744 - Entity List
Code of Federal Regulations, 2012 CFR
2012-01-01
...) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE EXPORT ADMINISTRATION REGULATIONS CONTROL POLICY... Beijing; —Institute of Control Devices (BICD); —Beijing Institute of Aerospace Control Devices (BIACD); —Beijing Aerospace Control Instruments Institute; and —Design and Manufacture Center of Navigation and...
Position calibration of a 3-DOF hand-controller with hybrid structure
NASA Astrophysics Data System (ADS)
Zhu, Chengcheng; Song, Aiguo
2017-09-01
A hand-controller is a human-robot interactive device, which measures the 3-DOF (Degree of Freedom) position of the human hand and sends it as a command to control robot movement. The device also receives 3-DOF force feedback from the robot and applies it to the human hand. Thus, the precision of 3-DOF position measurements is a key performance factor for hand-controllers. However, when using a hybrid type 3-DOF hand controller, various errors occur and are considered originating from machining and assembly variations within the device. This paper presents a calibration method to improve the position tracking accuracy of hybrid type hand-controllers by determining the actual size of the hand-controller parts. By re-measuring and re-calibrating this kind of hand-controller, the actual size of the key parts that cause errors is determined. Modifying the formula parameters with the actual sizes, which are obtained in the calibrating process, improves the end position tracking accuracy of the device.
Lee, Karla C L; Baker, Luisa A; Stanzani, Giacomo; Alibhai, Hatim; Chang, Yu Mei; Jimenez Palacios, Carolina; Leckie, Pamela J; Giordano, Paola; Priestnall, Simon L; Antoine, Daniel J; Jenkins, Rosalind E; Goldring, Christopher E; Park, B Kevin; Andreola, Fausto; Agarwal, Banwari; Mookerjee, Rajeshwar P; Davies, Nathan A; Jalan, Rajiv
2015-09-01
In acute liver failure, severity of liver injury and clinical progression of disease are in part consequent upon activation of the innate immune system. Endotoxaemia contributes to innate immune system activation and the detoxifying function of albumin, critical to recovery from liver injury, is irreversibly destroyed in acute liver failure. University College London-Liver Dialysis Device is a novel artificial extracorporeal liver assist device, which is used with albumin infusion, to achieve removal and replacement of dysfunctional albumin and reduction in endotoxaemia. We aimed to test the effect of this device on survival in a pig model of acetaminophen-induced acute liver failure. Pigs were randomised to three groups: Acetaminophen plus University College London-Liver Dialysis Device (n=9); Acetaminophen plus Control Device (n=7); and Control plus Control Device (n=4). Device treatment was initiated two h after onset of irreversible acute liver failure. The Liver Dialysis Device resulted in 67% reduced risk of death in acetaminophen-induced acute liver failure compared to Control Device (hazard ratio=0.33, p=0.0439). This was associated with 27% decrease in circulating irreversibly oxidised human non-mercaptalbumin-2 throughout treatment (p=0.046); 54% reduction in overall severity of endotoxaemia (p=0.024); delay in development of vasoplegia and acute lung injury; and delay in systemic activation of the TLR4 signalling pathway. Liver Dialysis Device-associated adverse clinical effects were not seen. The survival benefit and lack of adverse effects would support clinical trials of University College London-Liver Dialysis Device in acute liver failure patients. Copyright © 2015 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.
40 CFR 65.140 - Applicability.
Code of Federal Regulations, 2010 CFR
2010-07-01
... FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas System or a Process § 65..., shutdown, and malfunction provisions in § 65.6) apply to routing emissions to processes, fuel gas systems, closed vent systems, control devices, and recovery devices where another subpart expressly references the...
Code of Federal Regulations, 2011 CFR
2011-07-01
... stream components, not carbon equivalents. Car-seal means a seal that is placed on a device that is used..., flow inducing devices that transport gas or vapor from an emission point to a control device. A closed...), analyze, and provide a record of process or control system parameters. Continuous record means...
Code of Federal Regulations, 2010 CFR
2010-07-01
... recovery device (if any) and prior to any control device and prior to discharge to the atmosphere. Group 1..., these four technologies are considered equivalent. Reference control technology for wastewater means the..., not by carbon equivalents. Car-seal means a seal that is placed on a device that is used to change the...
Code of Federal Regulations, 2014 CFR
2014-07-01
... recovery device (if any) and prior to any control device and prior to discharge to the atmosphere. Group 1..., these four technologies are considered equivalent. Reference control technology for wastewater means the..., not by carbon equivalents. Car-seal means a seal that is placed on a device that is used to change the...
Code of Federal Regulations, 2011 CFR
2011-07-01
... recovery device (if any) and prior to any control device and prior to discharge to the atmosphere. Group 1..., these four technologies are considered equivalent. Reference control technology for wastewater means the..., not by carbon equivalents. Car-seal means a seal that is placed on a device that is used to change the...
Code of Federal Regulations, 2014 CFR
2014-07-01
... stream components, not carbon equivalents. Car-seal means a seal that is placed on a device that is used..., flow inducing devices that transport gas or vapor from an emission point to a control device. A closed...), analyze, and provide a record of process or control system parameters. Continuous record means...
Code of Federal Regulations, 2013 CFR
2013-07-01
... stream components, not carbon equivalents. Car-seal means a seal that is placed on a device that is used..., flow inducing devices that transport gas or vapor from an emission point to a control device. A closed...), analyze, and provide a record of process or control system parameters. Continuous record means...
Code of Federal Regulations, 2013 CFR
2013-07-01
... recovery device (if any) and prior to any control device and prior to discharge to the atmosphere. Group 1..., these four technologies are considered equivalent. Reference control technology for wastewater means the..., not by carbon equivalents. Car-seal means a seal that is placed on a device that is used to change the...
21 CFR 866.5910 - Quality control material for cystic fibrosis nucleic acid assays.
Code of Federal Regulations, 2010 CFR
2010-04-01
... HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological Test Systems § 866.5910 Quality control material for cystic fibrosis nucleic acid assays. (a... cystic fibrosis nucleic acid assays is a device intended to help monitor reliability of a test system by...
40 CFR 63.1431 - Process vent annual epoxides emission factor plan requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., recovery, or recapture device, along with the expected percent efficiency. (iii) Annual emissions after the... section, kg/yr. R = Expected control efficiency of the combustion, recovery, or recapture device, percent....1426(c) to determine the epoxide control efficiency of the combustion, recovery, or recapture device...
40 CFR 63.1431 - Process vent annual epoxides emission factor plan requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., recovery, or recapture device, along with the expected percent efficiency. (iii) Annual emissions after the... section, kg/yr. R = Expected control efficiency of the combustion, recovery, or recapture device, percent....1426(c) to determine the epoxide control efficiency of the combustion, recovery, or recapture device...
Code of Federal Regulations, 2012 CFR
2012-07-01
... recovery device (if any) and prior to any control device and prior to discharge to the atmosphere. Group 1..., these four technologies are considered equivalent. Reference control technology for wastewater means the..., not by carbon equivalents. Car-seal means a seal that is placed on a device that is used to change the...
40 CFR 63.690 - Standards: Process vents.
Code of Federal Regulations, 2011 CFR
2011-07-01
....693 of this subpart. For the purpose of complying with this paragraph (b), a primary condenser is not a control device; however, a second condenser or other organic recovery device that is operated downstream of the primary condenser is considered a control device. [64 FR 38970, July 20, 1999] ...
14 CFR 25.145 - Longitudinal control.
Code of Federal Regulations, 2010 CFR
2010-01-01
... complete retraction of the high lift devices from any position is begun during steady, straight, level...) If gated high-lift device control positions are provided, paragraph (c) of this section applies to retractions of the high-lift devices from any position from the maximum landing position to the first gated...
21 CFR 866.2480 - Quality control kit for culture media.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Quality control kit for culture media. 866.2480 Section 866.2480 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2480 Quality...
21 CFR 866.2480 - Quality control kit for culture media.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Quality control kit for culture media. 866.2480 Section 866.2480 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2480 Quality...
21 CFR 866.2480 - Quality control kit for culture media.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Quality control kit for culture media. 866.2480 Section 866.2480 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2480 Quality...
21 CFR 866.2480 - Quality control kit for culture media.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Quality control kit for culture media. 866.2480 Section 866.2480 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2480 Quality...
21 CFR 866.2480 - Quality control kit for culture media.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Quality control kit for culture media. 866.2480 Section 866.2480 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2480 Quality...
40 CFR 1045.801 - What definitions apply to this part?
Code of Federal Regulations, 2013 CFR
2013-07-01
... means any device, system, or element of design that someone can adjust (including those which are... emission control device means any element of design that senses temperature, motive speed, engine RPM... on a continuous mixture of those fuels. Emission control system means any device, system, or element...
40 CFR 60.692-5 - Standards: Closed vent systems and control devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (for example, condensers and adsorbers) shall be designed and operated to recover the VOC emissions... systems and control devices. (a) Enclosed combustion devices shall be designed and operated to reduce the... them. (e)(1) Closed vent systems shall be designed and operated with no detectable emissions, as...
21 CFR 890.3725 - Powered environmental control system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Powered environmental control system. 890.3725 Section 890.3725 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3725 Powered...
21 CFR 890.3725 - Powered environmental control system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Powered environmental control system. 890.3725 Section 890.3725 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3725 Powered...
21 CFR 890.3725 - Powered environmental control system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Powered environmental control system. 890.3725 Section 890.3725 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3725 Powered...
21 CFR 890.3725 - Powered environmental control system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Powered environmental control system. 890.3725 Section 890.3725 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3725 Powered...
21 CFR 890.3725 - Powered environmental control system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Powered environmental control system. 890.3725 Section 890.3725 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3725 Powered...
40 CFR 63.1326 - Batch process vents-recordkeeping provisions.
Code of Federal Regulations, 2011 CFR
2011-07-01
...): (i) For an incinerator or non-combustion control device, the percent reduction of organic HAP or TOC... introduced with combustion air or used as a secondary fuel and is not mixed with the primary fuel, the... scrubber or other halogen reduction device following a combustion device to control halogenated batch...
DOT National Transportation Integrated Search
2000-10-01
This report documents the second year of a two-year project to evaluate the effectiveness of innovative work zone traffic control devices. Researchers evaluated these devices at short-term rural work zones. During the second year of the project, seve...
Implantable physiologic controller for left ventricular assist devices with telemetry capability.
Asgari, Siavash S; Bonde, Pramod
2014-01-01
Rotary type left ventricular assist devices have mitigated the problem of durability associated with earlier pulsatile pumps and demonstrated improved survival. However, the compromise is the loss of pulsatility due to continuous flow and retained percutaneous driveline leading to increased mortality and morbidity. Lack of pulsatility is implicated in increased gastrointestinal bleeding, aortic incompetence, and diastolic hypertension. We present a novel, wirelessly powered, ultra-compact, implantable physiologic controller capable of running a left ventricular assist device in a pulsatile mode with wireless power delivery. The schematic of our system was laid out on a circuit board to wirelessly receive power and run a left ventricular assist device with required safety and backup measures. We have embedded an antenna and wireless network for telemetry. Multiple signal processing steps and controlling algorithm were incorporated. The controller was tested in in vitro and in vivo experiments. The controller drove left ventricular assist devices continuously for 2 weeks in an in vitro setup and in vivo without any failure. Our controller is more power efficient than the current Food and Drug Administration-approved left ventricular assist device controllers. When used with electrocardiography synchronization, the controller allowed on-demand customization of operation with instantaneous flow and revolutions per minute changes, resulting in a pulsatile flow with adjustable pulse pressure. Our test results prove the system to be remarkably safe, accurate, and efficient. The unique combination of wireless powering and small footprint makes this system an ideal totally implantable physiologic left ventricular assist device system. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Trenbath, Kim; Hannigan, Michael P.; Milford, Jana B.
2009-12-01
This study evaluates the effect of retrofit closed crankcase ventilation filters (CCFs) and diesel oxidation catalysts (DOCs) on the in-cabin air quality in transit-style diesel school buses. In-cabin pollution levels were measured on three buses from the Pueblo, CO District 70 fleet. Monitoring was conducted while buses were driven along their regular routes, with each bus tested three times before and three times after installation of control devices. Ultrafine number concentrations in the school bus cabins were 33-41% lower, on average, after the control devices were installed. Mean mass concentrations of particulate matter less than 2.5 μm in diameter (PM2.5) were 56% lower, organic carbon (OC) 41% lower, elemental carbon (EC) 85% lower, and formaldehyde 32% lower after control devices were installed. While carbon monoxide concentrations were low in all tests, mean concentrations were higher after control devices were installed than in pre-retrofit tests. Reductions in number, OC, and formaldehyde concentrations were statistically significant, but reductions in PM2.5 mass were not. Even with control devices installed, during some runs PM2.5 and OC concentrations in the bus cabins were elevated compared to ambient concentrations observed in the area. OC concentrations inside the bus cabins ranged from 22 to 58 μg m -3 before and 13 to 33 μg m -3 after control devices were installed. OC concentrations were correlated with particle-bound organic tracers for lubricating oil emissions (hopanes) and diesel fuel and tailpipe emissions (polycyclic aromatic hydrocarbons (PAH) and aliphatic hydrocarbons). Mean concentrations of hopanes, PAH, and aliphatic hydrocarbons were lower by 37, 50, and 43%, respectively, after the control devices were installed, suggesting that both CCFs and DOCs were effective at reducing in-cabin OC concentrations.
Actuator concepts and mechatronics
NASA Astrophysics Data System (ADS)
Gilbert, Michael G.; Horner, Garnett C.
1998-06-01
Mechatronic design implies the consideration of integrated mechanical, electrical, and local control characteristics in electromechanical device design. In this paper, mechatronic development of actuation device concepts for active aircraft aerodynamic flow control are presented and discussed. The devices are intended to be embedded in aircraft aerodynamic surfaces to provide zero-net-momentum jets or additional flow-vorticity to control boundary layers and flow- separation. Two synthetic jet device prototypes and one vorticity-on-demand prototype currently in development are described in the paper. The aspects of actuation materials, design approaches to generating jets and vorticity, and the integration of miniaturized electronics are stressed.
Operations manual for the patient assist device. [to handle electrical appliances
NASA Technical Reports Server (NTRS)
Schrader, M. A.
1973-01-01
Quadriplegic patients and multiple amputee patients are almost totally dependent on nursing personnel for any activities or interests in which they participate. A patient assist device is reported which provides patient control over electrical devices in his environment. The patient operates three switches to acquire control over a desired electrical appliance. The type switches employed are chosen to conform to patient capabilities, even when such capabilities are as limited as eye or head movements. The switch operations are sensed and converted into command signals by the patient assist device to control ten electrical appliances simulataneously and independently.
Dervan, Edward; Lee, Edward; Giubilato, Antonio; Khanam, Tina; Maghsoudlou, Panayiotis; Morgan, William H
2017-11-01
This study provides results of a treatment option for patients with failed primary glaucoma drainage device. The study aimed to describe and evaluate the long-term intraocular pressure control and complications of a new technique joining a second glaucoma drainage device directly to an existing glaucoma drainage device termed 'piggyback drainage'. This is a retrospective, interventional cohort study. Eighteen eyes of 17 patients who underwent piggyback drainage between 2004 and 2013 inclusive have been studied. All patients had prior glaucoma drainage device with uncontrolled intraocular pressure. The piggyback technique involved suturing a Baerveldt (250 or 350 mm) or Molteno3 glaucoma drainage device to an unused scleral quadrant and connecting the silicone tube to the primary plate bleb. Failure of intraocular pressure control defined as an intraocular pressure greater than 21 mmHg on maximal therapy on two separate occasions or further intervention to control intraocular pressure. The intraocular pressure was controlled in seven eyes (39%) at last follow-up with a mean follow-up time of 74.2 months. The mean preoperative intraocular pressure was 27.1 mmHg (95% confidence interval 23.8-30.3) compared with 18.4 mmHg (95% confidence interval 13.9-22.8) at last follow-up. The mean time to failure was 57.1 months (95% confidence interval 32.2-82), and the mean time to further surgery was 72.3 months (95% confidence interval 49.9-94.7). Lower preoperative intraocular pressure was associated with longer duration of intraocular pressure control (P = 0.048). If the intraocular pressure was controlled over 2 years, it continued to be controlled over the long term. Two eyes (11%) experienced corneal decompensation. Piggyback drainage represents a viable surgical alternative for the treatment of patients with severe glaucoma with failing primary glaucoma drainage device, particularly in those at high risk of corneal decompensation. © 2017 Royal Australian and New Zealand College of Ophthalmologists.
[Development of Biliary Contrast Agents Remote Pushing Device].
Zhu, Haoyang; Dong, Dinghui; Luo, Yu; Ren, Fenggang; Zhang, Jing; Tan, Wenjun; Shi, Aihua; Hu, Liangshuo; Wu, Rongqian; Lyu, Yi
2018-01-30
A biliary contrast agents pushing device, including a syringe pushing system and a remote controller is introduced. The syringe pushing system comprises an injector card slot, a support platform and an injection bolus fader. A 20 mL syringe can be fitted on the syringe pushing system and kept with the ground about 30 degree. This system can perform air bubble pumping back and contrast agents bolus injection as well as speed adjustment. Remote controller is an infrared remote control which can start and stop the syringe pushing system. With this device, the remote controlled cholangiography technology can be achieved, which can not only protect doctors from X-ray radiation but also improve the traditional T-tube cholangiography and the contrast effect, reduce postoperative complications in patients as well. The application of this device will improve the current diagnosis and treatment system, the device will benefit the majority of doctors and patients.
Systems and methods for controlling diesel engine emissions
Webb, Cynthia Chaffin; Weber, Phillip Anthony; Khair, Magdi K.
2004-06-01
Systems and methods for controlling diesel engine emissions, including, for example, oxides of nitrogen emissions, particulate matter emissions, and the like. The emission control system according to this invention is provided in the exhaust passageway of a diesel engine and includes a catalyst-based particulate filter; and first and second lean NO.sub.x trap systems coupled to the catalyst-based particulate filter. The first and second lean NO.sub.x trap systems are arranged in a parallel flow configuration with each other. Each of the first and second lean NO.sub.x trap systems include a carbon monoxide generating catalyst device, a sulfur trap device, a lean NO.sub.x device, a supplemental fuel injector device, and a plurality of flow diverter devices.
OCDR guided laser ablation device
Dasilva, Luiz B.; Colston, Jr., Bill W.; James, Dale L.
2002-01-01
A guided laser ablation device. The device includes a mulitmode laser ablation fiber that is surrounded by one or more single mode optical fibers that are used to image in the vicinity of the laser ablation area to prevent tissue damage. The laser ablation device is combined with an optical coherence domain reflectometry (OCDR) unit and with a control unit which initializes the OCDR unit and a high power laser of the ablation device. Data from the OCDR unit is analyzed by the control unit and used to control the high power laser. The OCDR images up to about 3 mm ahead of the ablation surface to enable a user to see sensitive tissue such as a nerve or artery before damaging it by the laser.
Electromechanically Actuated Multifunctional Wireless Auxetic Device for Wound Management.
Mir, Mariam; Ansari, Umar; Ali, Murtaza Najabat; Iftikhar, Muhammad Hassan Ul; Qayyum, Faisal
2017-01-01
The design and fabrication of a wound healing device for chronic wounds, with multiple functions for controlled drug delivery and exudate removal, has been described in this paper. The structural features have been machined and modified through laser cutting in a biocompatible polymer cast. Miniaturized versions of electronically actuated (lead-screw and pulley) mechanisms are used for the specific purpose of controlled drug delivery. These mechanisms have been studied and tested, being controlled through a microcontroller setup. An auxetic polymeric barrier membrane has been used for restricting the drug quantities administered. Drug delivery mechanisms are powered wirelessly, through an external, active RF component; this communicates with a passive component that is buried inside the wound healing device. The exudate removal efficiency of the device has been assessed through several simple tests using simulated wound exudate. It has been found that reasonably precise quantities of drug dosages to be administered to the wound site can be controlled through both drug delivery mechanisms; however, the lead-screw mechanism provides a better control of auxetic barrier membrane actuation and hence controlled drug delivery. We propose that this device can have potential clinical significance in controlled drug delivery and exudate removal in the management of chronic wounds.
Lee, Kevin S; Boccazzi, Paolo; Sinskey, Anthony J; Ram, Rajeev J
2011-05-21
This work reports on an instrument capable of supporting automated microscale continuous culture experiments. The instrument consists of a plastic-PDMS device capable of continuous flow without volume drift or evaporation. We apply direct computer controlled machining and chemical bonding fabrication for production of fluidic devices with a 1 mL working volume, high oxygen transfer rate (k(L)a≈0.025 s(-1)), fast mixing (2 s), accurate flow control (±18 nL), and closed loop control over temperature, cell density, dissolved oxygen, and pH. Integrated peristaltic pumps and valves provide control over input concentrations and allow the system to perform different types of cell culture on a single device, such as batch, chemostat, and turbidostat continuous cultures. Continuous cultures are demonstrated without contamination for 3 weeks in a single device and both steady state and dynamically controlled conditions are possible. © The Royal Society of Chemistry 2011
Miniature Trailing Edge Effector for Aerodynamic Control
NASA Technical Reports Server (NTRS)
Lee, Hak-Tae (Inventor); Bieniawski, Stefan R. (Inventor); Kroo, Ilan M. (Inventor)
2008-01-01
Improved miniature trailing edge effectors for aerodynamic control are provided. Three types of devices having aerodynamic housings integrated to the trailing edge of an aerodynamic shape are presented, which vary in details of how the control surface can move. A bucket type device has a control surface which is the back part of a C-shaped member having two arms connected by the back section. The C-shaped section is attached to a housing at the ends of the arms, and is rotatable about an axis parallel to the wing trailing edge to provide up, down and neutral states. A flip-up type device has a control surface which rotates about an axis parallel to the wing trailing edge to provide up, down, neutral and brake states. A rotating type device has a control surface which rotates about an axis parallel to the chord line to provide up, down and neutral states.
Network device interface for digitally interfacing data channels to a controller via a network
NASA Technical Reports Server (NTRS)
Ellerbrock, Philip J. (Inventor); Grant, Robert L. (Inventor); Winkelmann, Joseph P. (Inventor); Konz, Daniel W. (Inventor)
2009-01-01
A communications system and method are provided for digitally connecting a plurality of data channels, such as sensors, actuators, and subsystems, to a controller using a network bus. The network device interface interprets commands and data received from the controller and polls the data channels in accordance with these commands. Specifically, the network device interface receives digital commands and data from the controller, and based on these commands and data, communicates with the data channels to either retrieve data in the case of a sensor or send data to activate an actuator. Data retrieved from the sensor is converted into digital signals and transmitted to the controller. Network device interfaces associated with different data channels can coordinate communications with the other interfaces based on either a transition in a command message sent by the bus controller or a synchronous clock signal.
75 FR 78883 - Implementation of Additional Changes From the Annual Review of the Entity List
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-17
... are placed on the Entity List on the basis of certain sections of part 744 (Control Policy: End-User...; --Institute of Control Devices (BICD); --*Beijing Institute of Aerospace Control Devices (BIACD); --*Beijing Aerospace Control Instruments Institute; and --*Design and Manufacture Center of Navigation and Control...
Assistive Device Use in Visually Impaired Older Adults: Role of Control Beliefs
ERIC Educational Resources Information Center
Becker, Stefanie; Wahl, Hans-Werner; Schilling, Oliver; Burmedi, David
2005-01-01
Purpose: We investigate whether psychological control, conceptually framed within the life-span theory of control by Heckhausen and Schulz, drives assistive device use in visually impaired elders. In particular, we expect the two primary control modes differentiated in the life-span theory of control (i.e., selective primary and compensatory…
Bolie, V.W.
1990-07-03
A cooling system is provided for maintaining a preselected operating temperature in a device, which may be an RFQ accelerator, having a variable heat removal requirement, by circulating a cooling fluid through a cooling system remote from the device. Internal sensors in the device enable an estimated error signal to be generated from parameters which are indicative of the heat removal requirement from the device. Sensors are provided at predetermined locations in the cooling system for outputting operational temperature signals. Analog and digital computers define a control signal functionally related to the temperature signals and the estimated error signal, where the control signal is defined effective to return the device to the preselected operating temperature in a stable manner. The cooling system includes a first heat sink responsive to a first portion of the control signal to remove heat from a major portion of the circulating fluid. A second heat sink is responsive to a second portion of the control signal to remove heat from a minor portion of the circulating fluid. The cooled major and minor portions of the circulating fluid are mixed in response to a mixing portion of the control signal, which is effective to proportion the major and minor portions of the circulating fluid to establish a mixed fluid temperature which is effective to define the preselected operating temperature for the remote device. In an RFQ environment the stable temperature control enables the resonant frequency of the device to be maintained at substantially a predetermined value during transient operations. 3 figs.
Bolie, Victor W.
1990-01-01
A cooling system is provided for maintaining a preselected operating temperature in a device, which may be an RFQ accelerator, having a variable heat removal requirement, by circulating a cooling fluid through a cooling system remote from the device. Internal sensors in the device enable an estimated error signal to be generated from parameters which are indicative of the heat removal requirement from the device. Sensors are provided at predetermined locations in the cooling system for outputting operational temperature signals. Analog and digital computers define a control signal functionally related to the temperature signals and the estimated error signal, where the control signal is defined effective to return the device to the preselected operating temperature in a stable manner. The cooling system includes a first heat sink responsive to a first portion of the control signal to remove heat from a major portion of the circulating fluid. A second heat sink is responsive to a second portion of the control signal to remove heat from a minor portion of the circulating fluid. The cooled major and minor portions of the circulating fluid are mixed in response to a mixing portion of the control signal, which is effective to proportion the major and minor portions of the circulating fluid to establish a mixed fluid temperature which is effective to define the preselected operating temperature for the remote device. In an RFQ environment the stable temperature control enables the resonant frequency of the device to be maintained at substantially a predetermined value during transient operations.
Fluid flow sensing with ionic polymer-metal composites
NASA Astrophysics Data System (ADS)
Stalbaum, Tyler; Trabia, Sarah; Shen, Qi; Kim, Kwang J.
2016-04-01
Ionic polymer-metal composite (IPMC) actuators and sensors have been developed and modeled over the last two decades for use as soft-robotic deformable actuators and sensors. IPMC devices have been suggested for application as underwater actuators, energy harvesting devices, and medical devices such as in guided catheter insertion. Another interesting application of IPMCs in flow sensing is presented in this study. IPMC interaction with fluid flow is of interest to investigate the use of IPMC actuators as flow control devices and IPMC sensors as flow sensing devices. An organized array of IPMCs acting as interchanging sensors and actuators could potentially be designed for both flow measurement and control, providing an unparalleled tool in maritime operations. The underlying physics for this system include the IPMC ion transport and charge fundamental framework along with fluid dynamics to describe the flow around IPMCs. An experimental setup for an individual rectangular IPMC sensor with an externally controlled fluid flow has been developed to investigate this phenomenon and provide further insight into the design and application of this type of device. The results from this portion of the study include recommendations for IPMC device designs in flow control.
40 CFR 1054.801 - What definitions apply to this part?
Code of Federal Regulations, 2014 CFR
2014-07-01
... of this part. Auxiliary emission control device means any element of design that senses temperature... continuous mixture of those fuels. Emission control system means any device, system, or element of design... POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW, SMALL NONROAD SPARK-IGNITION ENGINES AND EQUIPMENT...
40 CFR 1054.801 - What definitions apply to this part?
Code of Federal Regulations, 2011 CFR
2011-07-01
... of this part. Auxiliary emission control device means any element of design that senses temperature... continuous mixture of those fuels. Emission control system means any device, system, or element of design... POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW, SMALL NONROAD SPARK-IGNITION ENGINES AND EQUIPMENT...
40 CFR 1054.801 - What definitions apply to this part?
Code of Federal Regulations, 2012 CFR
2012-07-01
... of this part. Auxiliary emission control device means any element of design that senses temperature... continuous mixture of those fuels. Emission control system means any device, system, or element of design... POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW, SMALL NONROAD SPARK-IGNITION ENGINES AND EQUIPMENT...
40 CFR 1054.801 - What definitions apply to this part?
Code of Federal Regulations, 2010 CFR
2010-07-01
... of this part. Auxiliary emission control device means any element of design that senses temperature... continuous mixture of those fuels. Emission control system means any device, system, or element of design... POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW, SMALL NONROAD SPARK-IGNITION ENGINES AND EQUIPMENT...
40 CFR 1054.801 - What definitions apply to this part?
Code of Federal Regulations, 2013 CFR
2013-07-01
... of this part. Auxiliary emission control device means any element of design that senses temperature... continuous mixture of those fuels. Emission control system means any device, system, or element of design... POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW, SMALL NONROAD SPARK-IGNITION ENGINES AND EQUIPMENT...
40 CFR 61.10 - Source reporting and waiver request.
Code of Federal Regulations, 2010 CFR
2010-07-01
... control equipment for each emission point including— (i) Each control device for each hazardous pollutant; and (ii) Estimated control efficiency (percent) for each control device. (7) A statement by the owner... 60 or part 63 standard, whichever is latest. Procedures governing the implementation of this...
NASA Technical Reports Server (NTRS)
Montgomery, Raymond C.; Scott, Michael A.; Weston, Robert P.
1998-01-01
This paper represents an initial study on the use of quasi-static shape change devices in aircraft maneuvering. The macroscopic effects and requirements for these devices in flight control are the focus of this study. Groups of devices are postulated to replace the conventional leading-edge flap (LEF) and the all-moving wing tip (AMT) on the tailless LMTAS-ICE (Lockheed Martin Tactical Aircraft Systems - Innovative Control Effectors) configuration. The maximum quasi-static shape changes are 13.8% and 7.7% of the wing section thickness for the LEF and AMT replacement devices, respectively. A Computational Fluid Dynamics (CFD) panel code is used to determine the control effectiveness of groups of these devices. A preliminary design of a wings-leveler autopilot is presented. Initial evaluation at 0.6 Mach at 15,000 ft. altitude is made through batch simulation. Results show small disturbance stability is achieved, however, an increase in maximum distortion is needed to statically offset five degrees of sideslip. This only applies to the specific device groups studied, encouraging future research on optimal device placement.
Aqoma, Havid; Al Mubarok, Muhibullah; Hadmojo, Wisnu Tantyo; Lee, Eun-Hye; Kim, Tae-Wook; Ahn, Tae Kyu; Oh, Seung-Hwan; Jang, Sung-Yeon
2017-05-01
Colloidal-quantum-dot (CQD) photovoltaic devices are promising candidates for low-cost power sources owing to their low-temperature solution processability and bandgap tunability. A power conversion efficiency (PCE) of >10% is achieved for these devices; however, there are several remaining obstacles to their commercialization, including their high energy loss due to surface trap states and the complexity of the multiple-step CQD-layer-deposition process. Herein, high-efficiency photovoltaic devices prepared with CQD-ink using a phase-transfer-exchange (PTE) method are reported. Using CQD-ink, the fabrication of active layers by single-step coating and the suppression of surface trap states are achieved simultaneously. The CQD-ink photovoltaic devices achieve much higher PCEs (10.15% with a certified PCE of 9.61%) than the control devices (7.85%) owing to improved charge drift and diffusion. Notably, the CQD-ink devices show much lower energy loss than other reported high-efficiency CQD devices. This result reveals that the PTE method is an effective strategy for controlling trap states in CQDs. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Device Oriented Project Controller
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dalesio, Leo; Kraimer, Martin
2013-11-20
This proposal is directed at the issue of developing control systems for very large HEP projects. A de-facto standard in accelerator control is the Experimental Physics and Industrial Control System (EPICS), which has been applied successfully to many physics projects. EPICS is a channel based system that requires that each channel of each device be configured and controlled. In Phase I, the feasibility of a device oriented extension to the distributed channel database was demonstrated by prototyping a device aware version of an EPICS I/O controller that functions with the current version of the channel access communication protocol. Extensions havemore » been made to the grammar to define the database. Only a multi-stage position controller with limit switches was developed in the demonstration, but the grammar should support a full range of functional record types. In phase II, a full set of record types will be developed to support all existing record types, a set of process control functions for closed loop control, and support for experimental beam line control. A tool to configure these records will be developed. A communication protocol will be developed or extensions will be made to Channel Access to support introspection of components of a device. Performance bench marks will be made on both communication protocol and the database. After these records and performance tests are under way, a second of the grammar will be undertaken.« less
2007-11-30
The Food and Drug Administration (FDA) is reclassifying from class III to class II the automated blood cell separator device operating by centrifugal separation principle and intended for the routine collection of blood and blood components. FDA is taking this action on its own initiative based on new information. Elsewhere in this issue of the Federal Register, FDA is announcing the availability of a guidance document that will serve as the special controls for this device, as well as the special controls for the device with the same intended use but operating on a filtration separation principle.
Application accelerator system having bunch control
Wang, D.; Krafft, G.A.
1999-06-22
An application accelerator system for monitoring the gain of a free electron laser is disclosed. Coherent Synchrotron Radiation (CSR) detection techniques are used with a bunch length monitor for ultra short, picosec to several tens of femtosec, electron bunches. The monitor employs an application accelerator, a coherent radiation production device, an optical or beam chopping device, an infrared radiation collection device, a narrow-banding filter, an infrared detection device, and a control. 1 fig.
2003-06-02
The Food and Drug Administration (FDA) is classifying the resorbable calcium salt bone void filler device intended to fill bony voids or gaps of the extremities, spine, and pelvis that are caused by trauma or surgery and are not intrinsic to the stability of the bony structure into class II (special controls). Elsewhere in this issue of the Federal Register, FDA is announcing the availability of a class II special controls guidance entitled "Class II Special Controls Guidance Document: Resorbable Calcium Salt Bone Void Filler Device; Guidance for Industry and FDA." This action is being undertaken based on new information submitted in a classification proposal from Wright Medical Technology under the Federal Food, Drug, and Cosmetic Act as amended by the Medical Device Amendments of 1976, the Safe Medical Devices Act of 1990, and the Food and Drug Administration Modernization Act of 1997.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Control Device for Open Molding Operations 4 Table 4 to Subpart VVVV of Part 63 Protection of Environment...-on Control Device for Open Molding Operations As specified in §§ 63.5715(a) and 63.5725(f)(5), you... data according to § 63.5725(d); b. reducing the data to 3-hour block averages; and c. maintaining the 3...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Control Device for Open Molding Operations 4 Table 4 to Subpart VVVV of Part 63 Protection of Environment...-on Control Device for Open Molding Operations As specified in §§ 63.5715(a) and 63.5725(f)(5), you... data according to § 63.5725(d); b. reducing the data to 3-hour block averages; and c. maintaining the 3...
Developing Control System of Electrical Devices with Operational Expense Prediction
NASA Astrophysics Data System (ADS)
Sendari, Siti; Wahyu Herwanto, Heru; Rahmawati, Yuni; Mukti Putranto, Dendi; Fitri, Shofiana
2017-04-01
The purpose of this research is to develop a system that can monitor and record home electrical device’s electricity usage. This system has an ability to control electrical devices in distance and predict the operational expense. The system was developed using micro-controllers and WiFi modules connected to PC server. The communication between modules is arranged by server via WiFi. Beside of reading home electrical devices electricity usage, the unique point of the proposed-system is the ability of micro-controllers to send electricity data to server for recording the usage of electrical devices. The testing of this research was done by Black-box method to test the functionality of system. Testing system run well with 0% error.
Code of Federal Regulations, 2010 CFR
2010-07-01
... control device. Control device means the air pollution control equipment used to reduce particulate matter... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Metallic Mineral Processing Plants § 60...
Code of Federal Regulations, 2014 CFR
2014-07-01
... control device. Control device means the air pollution control equipment used to reduce particulate matter... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Metallic Mineral Processing Plants § 60...
Code of Federal Regulations, 2013 CFR
2013-07-01
... control device. Control device means the air pollution control equipment used to reduce particulate matter... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Metallic Mineral Processing Plants § 60...
Code of Federal Regulations, 2011 CFR
2011-07-01
... control device. Control device means the air pollution control equipment used to reduce particulate matter... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Metallic Mineral Processing Plants § 60...