Code of Federal Regulations, 2013 CFR
2013-07-01
... system and add-on control device operating limits during the performance test? 63.4167 Section 63.4167... Emission Rate with Add-on Controls Option § 63.4167 How do I establish the emission capture system and add-on control device operating limits during the performance test? During the performance test required...
Code of Federal Regulations, 2011 CFR
2011-07-01
... system and add-on control device operating limits during the performance test? 63.4767 Section 63.4767... Rate with Add-on Controls Option § 63.4767 How do I establish the emission capture system and add-on control device operating limits during the performance test? During the performance test required by § 63...
Code of Federal Regulations, 2010 CFR
2010-07-01
... system and add-on control device operating limits during the performance test? 63.4767 Section 63.4767... Rate with Add-on Controls Option § 63.4767 How do I establish the emission capture system and add-on control device operating limits during the performance test? During the performance test required by § 63...
Code of Federal Regulations, 2010 CFR
2010-07-01
... system and add-on control device operating limits during the performance test? 63.4167 Section 63.4167... with Add-on Controls Option § 63.4167 How do I establish the emission capture system and add-on control device operating limits during the performance test? During the performance test required by § 63.4160...
Code of Federal Regulations, 2011 CFR
2011-07-01
... system and add-on control device operating limits during the performance test? 63.4167 Section 63.4167... with Add-on Controls Option § 63.4167 How do I establish the emission capture system and add-on control device operating limits during the performance test? During the performance test required by § 63.4160...
Code of Federal Regulations, 2010 CFR
2010-07-01
... device operating limits during the performance test? 63.3167 Section 63.3167 Protection of Environment... Limitations § 63.3167 How do I establish the add-on control device operating limits during the performance.... (a) Thermal oxidizers. If your add-on control device is a thermal oxidizer, establish the operating...
2017-10-18
The Food and Drug Administration (FDA or we) is classifying the organophosphate test system into class II (special controls). The special controls that apply to the device type are identified in this order and will be part of the codified language for the organophosphate test system's classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.
2018-01-03
The Food and Drug Administration (FDA or we) is classifying the cervical intraepithelial neoplasia (CIN) test system into class II (special controls). The special controls that apply to the device type are identified in this order and will be part of the codified language for the CIN test system's classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.
Crash Tests of Work Zone Traffic Control Devices
DOT National Transportation Integrated Search
1990-02-01
Full-scale vehicle crash tests evaluated performance of typical work zone traffic control devices. Modified test procedures and evaluation criteria from NCHRP Report 230 were used in 108 tests, providing significant insight into impact performance. P...
2017-12-27
The Food and Drug Administration (FDA or we) is classifying the flow cytometric test system for hematopoietic neoplasms into class II (special controls). The special controls that apply to the device type are identified in this order and will be part of the codified language for the flow cytometric test system for hematopoietic neoplasms' classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.
40 CFR 63.3400 - What notifications and reports must I submit?
Code of Federal Regulations, 2010 CFR
2010-07-01
... unknown causes. (I) The date of the latest CEMS and CPMS certification or audit. (J) A description of any... control device and you are required to conduct a performance test of the control device. This notification... of the control device determined during the performance test are maintained. Unless EPA objects to...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-23
... test system into class II (special controls). The special control that will apply to these devices is the guidance document entitled ``Guidance for Industry and FDA Staff; Class II Special Controls... devices into class II (special controls) because special controls, in addition to general controls, will...
Code of Federal Regulations, 2014 CFR
2014-07-01
... capture system and add-on control device operating limits during the performance test? 63.3556 Section 63... system and add-on control device operating limits during the performance test? During the performance... of key parameters of the valve operating system (e.g., solenoid valve operation, air pressure...
Code of Federal Regulations, 2012 CFR
2012-07-01
... capture system and add-on control device operating limits during the performance test? 63.3556 Section 63... system and add-on control device operating limits during the performance test? During the performance... of key parameters of the valve operating system (e.g., solenoid valve operation, air pressure...
Code of Federal Regulations, 2014 CFR
2014-07-01
... capture system and add-on control device operating limits during the performance test? 63.4966 Section 63... system and add-on control device operating limits during the performance test? During the performance... outlet gas temperature is the maximum operating limit for your condenser. (e) Emission capture system...
Code of Federal Regulations, 2012 CFR
2012-07-01
... capture system and add-on control device operating limits during the performance test? 63.4966 Section 63... system and add-on control device operating limits during the performance test? During the performance... outlet gas temperature is the maximum operating limit for your condenser. (e) Emission capture system...
21 CFR 862.1660 - Quality control material (assayed and unassayed).
Code of Federal Regulations, 2013 CFR
2013-04-01
... SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry... control material (assayed and unassayed) for clinical chemistry is a device intended for medical purposes for use in a test system to estimate test precision and to detect systematic analytical deviations...
21 CFR 862.1660 - Quality control material (assayed and unassayed).
Code of Federal Regulations, 2014 CFR
2014-04-01
... SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry... control material (assayed and unassayed) for clinical chemistry is a device intended for medical purposes for use in a test system to estimate test precision and to detect systematic analytical deviations...
21 CFR 862.1660 - Quality control material (assayed and unassayed).
Code of Federal Regulations, 2012 CFR
2012-04-01
... SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry... control material (assayed and unassayed) for clinical chemistry is a device intended for medical purposes for use in a test system to estimate test precision and to detect systematic analytical deviations...
40 CFR 63.5767 - What records must I keep?
Code of Federal Regulations, 2013 CFR
2013-07-01
... facility is not controlled by an add-on control device (i.e., you are complying with organic HAP content... add-on control device, you must keep the records specified in § 63.10(b) relative to control device startup, shut down, and malfunction events; control device performance tests; and continuous monitoring...
40 CFR 63.5767 - What records must I keep?
Code of Federal Regulations, 2012 CFR
2012-07-01
... facility is not controlled by an add-on control device (i.e., you are complying with organic HAP content... add-on control device, you must keep the records specified in § 63.10(b) relative to control device startup, shut down, and malfunction events; control device performance tests; and continuous monitoring...
40 CFR 63.5767 - What records must I keep?
Code of Federal Regulations, 2014 CFR
2014-07-01
... facility is not controlled by an add-on control device (i.e., you are complying with organic HAP content... add-on control device, you must keep the records specified in § 63.10(b) relative to control device startup, shut down, and malfunction events; control device performance tests; and continuous monitoring...
49 CFR 236.586 - Daily or after trip test.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.586 Daily or after trip test..., each locomotive equipped with an automatic cab signal or train stop or train control device operating...
49 CFR 236.586 - Daily or after trip test.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.586 Daily or after trip test..., each locomotive equipped with an automatic cab signal or train stop or train control device operating...
2014-09-03
The Food and Drug Administration (FDA) is classifying early growth response 1 (EGR1) gene fluorescence in-situ hybridization (FISH) test system for specimen characterization into class II (special controls). The special controls that will apply to this device are identified in this order and will be part of the codified language for the early growth response 1 (EGR1) gene fluorescence in-site hybridization (FISH) test system for specimen characterization classification. The Agency is classifying the device into class II (special controls) in order to provide a reasonable assurance of safety and effectiveness of the device.
Code of Federal Regulations, 2013 CFR
2013-07-01
... system and add-on control device operating limits during the performance test? 63.4767 Section 63.4767... system and add-on control device operating limits during the performance test? During the performance... operating limits required by § 63.4692 according to this section, unless you have received approval for...
Code of Federal Regulations, 2010 CFR
2010-07-01
... system and add-on control device operating limits during the performance test? 63.3967 Section 63.3967... capture system and add-on control device operating limits during the performance test? During the... the operating limits required by § 63.3892 according to this section, unless you have received...
Code of Federal Regulations, 2011 CFR
2011-07-01
... system and add-on control device operating limits during the performance test? 63.3967 Section 63.3967... capture system and add-on control device operating limits during the performance test? During the... the operating limits required by § 63.3892 according to this section, unless you have received...
Code of Federal Regulations, 2013 CFR
2013-07-01
... system and add-on control device operating limits during the performance test? 63.3967 Section 63.3967... emission capture system and add-on control device operating limits during the performance test? During the... the operating limits required by § 63.3892 according to this section, unless you have received...
Code of Federal Regulations, 2012 CFR
2012-07-01
... capture system and add-on control device operating limits during the performance test? 63.4167 Section 63... capture system and add-on control device operating limits during the performance test? During the... the operating limits required by § 63.4092 according to this section unless you have received approval...
Code of Federal Regulations, 2014 CFR
2014-07-01
... capture system and add-on control device operating limits during the performance test? 63.4567 Section 63... emission capture system and add-on control device operating limits during the performance test? During the... the operating limits required by § 63.4492 according to this section, unless you have received...
Code of Federal Regulations, 2014 CFR
2014-07-01
... capture system and add-on control device operating limits during the performance test? 63.3967 Section 63... establish the emission capture system and add-on control device operating limits during the performance test... must establish the operating limits required by § 63.3892 according to this section, unless you have...
Code of Federal Regulations, 2014 CFR
2014-07-01
... capture system and add-on control device operating limits during the performance test? 63.4167 Section 63... capture system and add-on control device operating limits during the performance test? During the... the operating limits required by § 63.4092 according to this section unless you have received approval...
Code of Federal Regulations, 2014 CFR
2014-07-01
... capture system and add-on control device operating limits during the performance test? 63.4767 Section 63... capture system and add-on control device operating limits during the performance test? During the... the operating limits required by § 63.4692 according to this section, unless you have received...
Code of Federal Regulations, 2012 CFR
2012-07-01
... capture system and add-on control device operating limits during the performance test? 63.4767 Section 63... capture system and add-on control device operating limits during the performance test? During the... the operating limits required by § 63.4692 according to this section, unless you have received...
Code of Federal Regulations, 2012 CFR
2012-07-01
... capture system and add-on control device operating limits during the performance test? 63.3967 Section 63... establish the emission capture system and add-on control device operating limits during the performance test... must establish the operating limits required by § 63.3892 according to this section, unless you have...
Code of Federal Regulations, 2012 CFR
2012-07-01
... capture system and add-on control device operating limits during the performance test? 63.4567 Section 63... emission capture system and add-on control device operating limits during the performance test? During the... the operating limits required by § 63.4492 according to this section, unless you have received...
Code of Federal Regulations, 2013 CFR
2013-07-01
... system and add-on control device operating limits during the performance test? 63.4567 Section 63.4567... capture system and add-on control device operating limits during the performance test? During the... the operating limits required by § 63.4492 according to this section, unless you have received...
21 CFR 866.5910 - Quality control material for cystic fibrosis nucleic acid assays.
Code of Federal Regulations, 2010 CFR
2010-04-01
... HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological Test Systems § 866.5910 Quality control material for cystic fibrosis nucleic acid assays. (a... cystic fibrosis nucleic acid assays is a device intended to help monitor reliability of a test system by...
ASSESSMENT OF EXISTING TEST REPORTS FOR EVALUATING VOC CONTROL EFFECTIVENESS
The report outlines the approach taken by EPA to review existing test reports for evaluating volatile organic compound (VOC) control device effectiveness and identifying missing control device effectiveness information. A format is presented to provide guidance and serve as the b...
21 CFR 862.1795 - Vanilmandelic acid test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test... certain hypertensive conditions. (b) Classification. Class I (general controls). The device is exempt from...
21 CFR 862.1335 - Glucagon test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862... mellitus, hypoglycemia, and hyperglycemia. (b) Classification. Class I (general controls). The device is...
A Wearable Body Controlling Device for Application of Functional Electrical Stimulation
Jeffery, Nicholas D.
2018-01-01
In this research, we describe a new balancing device used to stabilize the rear quarters of a patient dog with spinal cord injuries. Our approach uses inertial measurement sensing and direct leg actuation to lay a foundation for eventual muscle control by means of direct functional electrical stimulation (FES). During this phase of development, we designed and built a mechanical test-bed to develop the control and stimulation algorithms before we use the device on our animal subjects. We designed the bionic test-bed to mimic the typical walking gait of a dog and use it to develop and test the functionality of the balancing device for stabilization of patient dogs with hindquarter paralysis. We present analysis for various muscle stimulation and balancing strategies, and our device can be used by veterinarians to tailor the stimulation strength and temporal distribution for any individual patient dog. We develop stabilizing muscle stimulation strategies using the robotic test-bed to enhance walking stability. We present experimental results using the bionic test-bed to demonstrate that the balancing device can provide an effective sensing strategy and deliver the required motion control commands for stabilizing an actual dog with a spinal cord injury. PMID:29670039
A Wearable Body Controlling Device for Application of Functional Electrical Stimulation.
Taghavi, Nazita; Luecke, Greg R; Jeffery, Nicholas D
2018-04-18
In this research, we describe a new balancing device used to stabilize the rear quarters of a patient dog with spinal cord injuries. Our approach uses inertial measurement sensing and direct leg actuation to lay a foundation for eventual muscle control by means of direct functional electrical stimulation (FES). During this phase of development, we designed and built a mechanical test-bed to develop the control and stimulation algorithms before we use the device on our animal subjects. We designed the bionic test-bed to mimic the typical walking gait of a dog and use it to develop and test the functionality of the balancing device for stabilization of patient dogs with hindquarter paralysis. We present analysis for various muscle stimulation and balancing strategies, and our device can be used by veterinarians to tailor the stimulation strength and temporal distribution for any individual patient dog. We develop stabilizing muscle stimulation strategies using the robotic test-bed to enhance walking stability. We present experimental results using the bionic test-bed to demonstrate that the balancing device can provide an effective sensing strategy and deliver the required motion control commands for stabilizing an actual dog with a spinal cord injury.
Developing Control System of Electrical Devices with Operational Expense Prediction
NASA Astrophysics Data System (ADS)
Sendari, Siti; Wahyu Herwanto, Heru; Rahmawati, Yuni; Mukti Putranto, Dendi; Fitri, Shofiana
2017-04-01
The purpose of this research is to develop a system that can monitor and record home electrical device’s electricity usage. This system has an ability to control electrical devices in distance and predict the operational expense. The system was developed using micro-controllers and WiFi modules connected to PC server. The communication between modules is arranged by server via WiFi. Beside of reading home electrical devices electricity usage, the unique point of the proposed-system is the ability of micro-controllers to send electricity data to server for recording the usage of electrical devices. The testing of this research was done by Black-box method to test the functionality of system. Testing system run well with 0% error.
Chan, Amy Hai Yan; Stewart, Alistair William; Harrison, Jeff; Black, Peter Nigel; Mitchell, Edwin Arthur; Foster, Juliet Michelle
2017-05-01
To investigate the performance and patient acceptability of an inhaler electronic monitoring device in a real-world childhood asthma population. Children 6 to 15 years presenting with asthma to the hospital emergency department and prescribed inhaled corticosteroids were included. Participants were randomized to receive a device with reminder features enabled or disabled for use with their preventer. Device quality control tests were conducted. Questionnaires on device acceptability, utility and ergonomics were completed at six months. A total of 1306 quality control tests were conducted; 84% passed pre-issue and 87% return testing. The most common failure reason was actuation under-recording. Acceptability scores were high, with higher scores in the reminder than non-reminder group (median, 5 th -95 th percentile: 4.1, 3.1-5.0 versus 3.7, 2.3-4.8; p < 0.001). Most (>90%) rated the device easy to use. Feedback was positive across five themes: device acceptability, ringtone acceptability, suggestions for improvement, effect on medication use, and effect on asthma control. This study investigates electronic monitoring device performance and acceptability in children using quantitative and qualitative measures. Results indicate satisfactory reliability, although failure rates of 13-16% indicate the importance of quality control. Favorable acceptability ratings support the use of these devices in children.
21 CFR 862.1490 - Lysozyme (muramidase) test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test... monocytic leukemia and kidney disease. (b) Classification. Class I (general controls). The device is exempt...
21 CFR 862.1430 - 17-Ketosteroids test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862... hypertension, diabetes, and hypothyroidism. (b) Classification. Class I (general controls). The device is...
21 CFR 862.1500 - Malic dehydrogenase test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test... marrow) leukemia. (b) Classification. Class I (general controls). The device is exempt from the premarket...
On shaky ground - A study of security vulnerabilities in control protocols
DOE Office of Scientific and Technical Information (OSTI.GOV)
Byres, E. J.; Huffman, D.; Kube, N.
2006-07-01
The recent introduction of information technologies such as Ethernet R into nuclear industry control devices has resulted in significantly less isolation from the outside world. This raises the question of whether these systems could be attacked by malware, network hackers or professional criminals to cause disruption to critical operations in a manner similar to the impacts now felt in the business world. To help answer this question, a study was undertaken to test a representative control protocol to determine if it had vulnerabilities that could be exploited. A framework was created in which a test could express a large numbermore » of test cases in very compact formal language. This in turn, allowed for the economical automation of both the generation of selectively malformed protocol traffic and the measurement of device under test's (DUT) behavior in response to this traffic. Approximately 5000 protocol conformance tests were run against two major brands of industrial controller. More than 60 categories of errors were discovered, the majority of which were in the form of incorrect error responses to malformed traffic. Several malformed packets however, caused the device to respond or communicate in inappropriate ways. These would be relatively simple for an attacker to inject into a system and could result in the plant operator losing complete view or control of the control device. Based on this relatively small set of devices, we believe that the nuclear industry urgently needs to adopt better security robustness testing of control devices as standard practice. (authors)« less
An Automatic Occlusion Device for Remote Control of Tumor Tissue Ischemia
El-Dahdah, Hamid; Wang, Bei; He, Guanglong; Xu, Ronald X.
2015-01-01
We developed an automatic occlusion device for remote control of tumor tissue ischemia. The device consists of a flexible cannula encasing a shape memory alloy wire with its distal end connected to surgical suture. Regional tissue occlusion was tested on both the benchtop and the animal models. In the benchtop test, the occlusion device introduced quantitative and reproducible changes of blood flow in a tissue simulating phantom embedding a vessel simulator. In the animal test, the device generated a cyclic pattern of reversible ischemia in the right hinder leg tissue of a black male C57BL/6 mouse. We also developed a multimodal detector that integrates near infrared spectroscopy and electron paramagnetic resonance spectroscopy for continuous monitoring of tumor tissue oxygenation, blood content, and oxygen tension changes. The multimodal detector was tested on a cancer xenograft nude mouse undergoing reversible tumor ischemia. The automatic occlusion device and the multi-modal detector can be potentially integrated for closed-loop feedback control of tumor tissue ischemia. Such an integrated occlusion device may be used in multiple clinical applications such as regional hypoperfusion control in tumor resection surgeries and thermal ablation processes. In addition, the proposed occlusion device can also be used as a research tool to understand tumor oxygen transport and hemodynamic characteristics. PMID:20082532
21 CFR 862.1380 - Hydroxybutyric dehydrogenase test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test... (general controls). The device is exempt from the premarket notification procedures in subpart E of part...
21 CFR 862.1330 - Globulin test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862... other disorders of blood globulins. (b) Classification. Class I (general controls). The device is exempt...
21 CFR 862.1470 - Lipid (total) test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862.... (b) Classification. Class I (general controls). The device is exempt from the premarket notification...
21 CFR 862.1805 - Vitamin A test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862.... (b) Classification. Class I (general controls). The device is exempt from the premarket notification...
21 CFR 862.1605 - Pregnanediol test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862...) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in...
21 CFR 862.1610 - Pregnanetriol test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862... (congenital enlargement of the adrenal gland). (b) Classification. Class I (general controls). The device is...
21 CFR 862.1395 - 17-Hydroxyprogesterone test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test... adrenal glands or the ovaries. (b) Classification. Class I (general controls). The device is exempt from...
Evaluation of steering control devices in adapted cars using sled deceleration tests
NASA Astrophysics Data System (ADS)
Eixerés, B.; Masiá, J.; Dols, J. F.; Esquerdo, T. V.
2009-11-01
Steering control devices used by disabled drivers can reduce passive safety, interfering with the existing systems of safety in the vehicle or causing injury to the occupants [1]. In this article, the results obtained in different dynamic tests carried out in a crash test simulator are presented. These tests were carried out on the steering devices which interfere the most with the deployment of the driver's airbag and also with the knee airbag in a Citroen C5.
21 CFR 862.1590 - Porphobilinogen test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862... (general controls). The device is exempt from the premarket notification procedures in subpart E of part...
21 CFR 862.1790 - Uroporphyrin test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862... (general controls). The device is exempt from the premarket notification procedures in subpart E of part...
21 CFR 862.1595 - Porphyrins test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862... (general controls). The device is exempt from the premarket notification procedures in subpart E of part...
21 CFR 862.1325 - Gastrin test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862...-secreting tumor of the pancreas). (b) Classification. Class I (general controls). The device is exempt from...
21 CFR 862.1620 - Progesterone test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862... (general controls). The device is exempt from the premarket notification procedures in subpart E of part...
A generic approach for examining the effectiveness of traffic control devices in school zones.
Zhao, Xiaohua; Li, Jiahui; Ding, Han; Zhang, Guohui; Rong, Jian
2015-09-01
The effectiveness and performance of traffic control devices in school zones have been impacted significantly by many factors, such as driver behavioral attributes, roadway geometric features, environmental characteristics, weather and visibility conditions, region-wide traffic regulations and policies, control modes, etc. When deploying traffic control devices in school zones, efforts are needed to clarify: (1) whether traffic control device installation is warranted; and (2) whether other device effectively complements this traffic control device and strengthens its effectiveness. In this study, a generic approach is developed to examine and evaluate the effectiveness of various traffic control devices deployed in school zones through driving simulator-based experiments. A Traffic Control Device Selection Model (TCDSM) is developed and two representative school zones are selected as the testbed in Beijing for driving simulation implementation to enhance its applicability. Statistical analyses are conducted to extract the knowledge from test data recorded by a driving simulator. Multiple measures of effectiveness (MOEs) are developed and adopted including average speed, relative speed difference, and standard deviation of acceleration for traffic control device performance quantification. The experimental tests and analysis results reveal that the appropriateness of the installation of certain traffic control devices can be statistically verified by TCDSM. The proposed approach provides a generic framework to assess traffic control device performance in school zones including experiment design, statistical formulation, data analysis, simulation model implementation, data interpretation, and recommendation development. Copyright © 2015 Elsevier Ltd. All rights reserved.
Code of Federal Regulations, 2011 CFR
2011-07-01
... device emission destruction or removal efficiency? 63.9323 Section 63.9323 Protection of Environment... determine the add-on control device emission destruction or removal efficiency? You must use the procedures... removal efficiency as part of the performance test required by § 63.9310. You must conduct three test runs...
Code of Federal Regulations, 2010 CFR
2010-07-01
... device emission destruction or removal efficiency? 63.9323 Section 63.9323 Protection of Environment... determine the add-on control device emission destruction or removal efficiency? You must use the procedures... removal efficiency as part of the performance test required by § 63.9310. You must conduct three test runs...
Code of Federal Regulations, 2011 CFR
2011-07-01
... device emission destruction or removal efficiency? 63.4566 Section 63.4566 Protection of Environment... efficiency? You must use the procedures and test methods in this section to determine the add-on control device emission destruction or removal efficiency as part of the performance test required by § 63.4560...
Code of Federal Regulations, 2010 CFR
2010-07-01
... device emission destruction or removal efficiency? 63.3966 Section 63.3966 Protection of Environment... or removal efficiency? You must use the procedures and test methods in this section to determine the add-on control device emission destruction or removal efficiency as part of the performance test...
Code of Federal Regulations, 2010 CFR
2010-07-01
... device emission destruction or removal efficiency? 63.4566 Section 63.4566 Protection of Environment... efficiency? You must use the procedures and test methods in this section to determine the add-on control device emission destruction or removal efficiency as part of the performance test required by § 63.4560...
Code of Federal Regulations, 2011 CFR
2011-07-01
... device emission destruction or removal efficiency? 63.3966 Section 63.3966 Protection of Environment... or removal efficiency? You must use the procedures and test methods in this section to determine the add-on control device emission destruction or removal efficiency as part of the performance test...
21 CFR 862.1615 - Pregnenolone test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862... diseases of the adrenal cortex or the gonads. (b) Classification. Class I (general controls). The device is...
Klute, G K; Tasch, U; Geselowitz, D B
1992-04-01
This paper addresses the development and testing of an optimal position feedback controller for the Penn State electric ventricular-assist device (EVAD). The control law is designed to minimize the expected value of the EVAD's power consumption for a targeted patient population. The closed-loop control law is implemented on an Intel 8096 microprocessor and in vitro test runs show that this controller improves the EVAD's efficiency by 15-21%, when compared with the performance of the currently used feedforward control scheme.
40 CFR 63.5716 - When must I conduct a performance test?
Code of Federal Regulations, 2010 CFR
2010-07-01
... PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES... for Open Molding Operations Controlled by Add-on Control Devices § 63.5716 When must I conduct a performance test? (a) If your source is an existing source, you must complete the add-on control device...
Determining Desirable Cursor Control Device Characteristics for NASA Exploration Missions
NASA Technical Reports Server (NTRS)
Sandor, Aniko; Holden, Kritina L.
2007-01-01
A test battery was developed for cursor control device evaluation: four tasks were taken from ISO 9241-9, and three from previous studies conducted at NASA. The tasks focused on basic movements such as pointing, clicking, and dragging. Four cursor control devices were evaluated with and without Extravehicular Activity (EVA) gloves to identify desirable cursor control device characteristics for NASA missions: 1) the Kensington Expert Mouse, 2) the Hulapoint mouse, 3) the Logitech Marble Mouse, and 4) the Honeywell trackball. Results showed that: 1) the test battery is an efficient tool for differentiating among input devices, 2) gloved operations were about 1 second slower and had at least 15% more errors; 3) devices used with gloves have to be larger, and should allow good hand positioning to counteract the lack of tactile feedback, 4) none of the devices, as designed, were ideal for operation with EVA gloves.
Experimental traffic control device testing at New Hampshire toll plazas.
DOT National Transportation Integrated Search
2007-06-01
This report includes a description of the testing and evaluation methodology of the E-ZPassSM Purple Light Experiment. Purple lights with : advanced signs were installed as supplemental traffic control devices for northbound and southbound E-Zp...
Testing device subjects elastic materials to biaxial deformations
NASA Technical Reports Server (NTRS)
Becker, G. W.
1965-01-01
Testing device stretches elastic materials biaxially over large deformation ranges and varies strain ratios in two perpendicular directions. The device is used in conjunction with a tensile testing machine, which holds the specimen and permits control over the direction and magnitude of the stresses applied.
Code of Federal Regulations, 2010 CFR
2010-07-01
... system and add-on control device operating limits during the performance test? 63.3546 Section 63.3546... device or system of multiple capture devices. The average duct static pressure is the maximum operating... Add-on Controls Option § 63.3546 How do I establish the emission capture system and add-on control...
Code of Federal Regulations, 2011 CFR
2011-07-01
... system and add-on control device operating limits during the performance test? 63.3546 Section 63.3546... device or system of multiple capture devices. The average duct static pressure is the maximum operating... Add-on Controls Option § 63.3546 How do I establish the emission capture system and add-on control...
40 CFR 63.5767 - What records must I keep?
Code of Federal Regulations, 2011 CFR
2011-07-01
... by an add-on control device (i.e., you are complying with organic HAP content limits, application...-average organic HAP content as determined in § 63.5749. (d) If your facility has an add-on control device... malfunction events; control device performance tests; and continuous monitoring system performance evaluations. ...
40 CFR 63.5767 - What records must I keep?
Code of Federal Regulations, 2010 CFR
2010-07-01
... by an add-on control device (i.e., you are complying with organic HAP content limits, application...-average organic HAP content as determined in § 63.5749. (d) If your facility has an add-on control device... malfunction events; control device performance tests; and continuous monitoring system performance evaluations. ...
HARD CHROME POLLUTION PREVENTION DEMONSTRATION PROJECT - INTERIM REPORT
In the project, five chromium emission prevention/control devices were tested tha cover the spectrum of prevention/control techniques currently in use in small- and large-size hard chromium electroplating job shops. The Project results show that some of the tested devices had ch...
NASA Astrophysics Data System (ADS)
Sihombing, Oloan; Zendrato, Niskarto; Laia, Yonata; Nababan, Marlince; Sitanggang, Delima; Purba, Windania; Batubara, Diarmansyah; Aisyah, Siti; Indra, Evta; Siregar, Saut
2018-04-01
In the era of technological development today, the technology has become the need for the life of today's society. One is needed to create a smart home in turning on and off electronic devices via smartphone. So far in turning off and turning the home electronic device is done by pressing the switch or remote button, so in control of electronic device control less effective. The home smart design is done by simulation concept by testing system, network configuration, and wireless home gateway computer network equipment required by a smart home network on cisco packet tracer using Internet Thing (IoT) control. In testing the IoT home network wireless network gateway system, multiple electronic devices can be controlled and monitored via smartphone based on predefined configuration conditions. With the Smart Ho me can potentially increase energy efficiency, decrease energy usage costs, control electronics and change the role of residents.
NASA Technical Reports Server (NTRS)
Johnson, Harold I.
1946-01-01
Results of flight tests of a control-feel aid presented. This device consisted of a spring and dashpot connected in series between the control stick and airplane structure. The device was tested in combination with an experimental elevator and bobweight which had given unsatisfactory dynamic stability and control-feel characteristics in previous tests. The control-feel aid effected marked improvement in both the control-feel characteristics and the control-feel dynamic longitudinal stability of the airplane.
Validity and reliability of a new ankle dorsiflexion measurement device.
Gatt, Alfred; Chockalingam, Nachiappan
2013-08-01
The assessment of the maximum ankle dorsiflexion angle is an important clinical examination procedure. Evidence shows that the traditional goniometer is highly unreliable, and various designs of goniometers to measure the maximum ankle dorsiflexion angle rely on the application of a known force to obtain reliable results. Hence, an innovative ankle dorsiflexion measurement device was designed to make this measurement more reliable by holding the foot in a selected posture without the application of a known moment. To report on the comprehensive validity and reliability testing carried out on the new device. Following validity testing, four different trials to test reliability of the ankle dorsiflexion measurement device were performed. These trials included inter-rater and intra-rater testings with a controlled moment, intra-rater reliability testing with knees flexed and extended without a controlled moment, intra-rater testing with a patient population, and inter-rater reliability testing between four raters of varying experience without controlling moment. All raters were blinded. A series of trials to test intra-rater and inter-rater reliabilities. Intra-rater reliability intraclass correlation coefficient was 0.98 and inter-rater reliability intraclass correlation coefficient (2,1) was 0.953 with a controlled moment. With uncontrolled moment, very high reliability for intra-tester was also achieved (intraclass correlation coefficient = 0.94 with knees extended and intraclass correlation coefficient = 0.95 with knees flexed). For the trial investigating test-retest reliability with actual patients, intraclass correlation coefficient of 0.99 was obtained. In the trial investigating four different raters with uncontrolled moment, intraclass correlation coefficient of 0.91 was achieved. The new ankle dorsiflexion measurement device is a valid and reliable device for measuring ankle dorsiflexion in both healthy subjects and patients, with both controlled and uncontrolled moments, even by multiple raters of varying experience when the foot is dorsiflexed to its end of range of motion. An ankle dorsiflexion measuring device has been designed to increase the reliability of ankle dorsiflexion measurement and replace the traditional goniometer. While the majority of similar devices rely on application of a known moment to perform this measurement, it has been shown that this is not required with the new ankle dorsiflexion measurement device and, rather, foot posture should be taken into consideration as this affects the maximum ankle dorsiflexion angle.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pollet, J.
2006-07-01
This session starts by providing an overview of typical DCS (Distributed Control Systems) and SCADA (Supervisory Control and Data Acquisition) architectures, and exposes cyber security vulnerabilities that vendors never admit, but are found through a comprehensive cyber testing process. A complete assessment process involves testing all of the layers and components of a SCADA or DCS environment, from the perimeter firewall all the way down to the end devices controlling the process, including what to look for when conducting a vulnerability assessment of real-time control systems. The following systems are discussed: 1. Perimeter (isolation from corporate IT or other non-criticalmore » networks) 2. Remote Access (third Party access into SCADA or DCS networks) 3. Network Architecture (switch, router, firewalls, access controls, network design) 4. Network Traffic Analysis (what is running on the network) 5. Host Operating Systems Hardening 6. Applications (how they communicate with other applications and end devices) 7. End Device Testing (PLCs, RTUs, DCS Controllers, Smart Transmitters) a. System Discovery b. Functional Discovery c. Attack Methodology i. DoS Tests (at what point does the device fail) ii. Malformed Packet Tests (packets that can cause equipment failure) iii. Session Hijacking (do anything that the operator can do) iv. Packet Injection (code and inject your own SCADA commands) v. Protocol Exploitation (Protocol Reverse Engineering / Fuzzing) This paper will provide information compiled from over five years of conducting cyber security testing on control systems hardware, software, and systems. (authors)« less
Intelligent Control Wheelchair Using a New Visual Joystick.
Rabhi, Yassine; Mrabet, Makrem; Fnaiech, Farhat
2018-01-01
A new control system of a hand gesture-controlled wheelchair (EWC) is proposed. This smart control device is suitable for a large number of patients who cannot manipulate a standard joystick wheelchair. The movement control system uses a camera fixed on the wheelchair. The patient's hand movements are recognized using a visual recognition algorithm and artificial intelligence software; the derived corresponding signals are thus used to control the EWC in real time. One of the main features of this control technique is that it allows the patient to drive the wheelchair with a variable speed similar to that of a standard joystick. The designed device "hand gesture-controlled wheelchair" is performed at low cost and has been tested on real patients and exhibits good results. Before testing the proposed control device, we have created a three-dimensional environment simulator to test its performances with extreme security. These tests were performed on real patients with diverse hand pathologies in Mohamed Kassab National Institute of Orthopedics, Physical and Functional Rehabilitation Hospital of Tunis, and the validity of this intelligent control system had been proved.
Intelligent Control Wheelchair Using a New Visual Joystick
Mrabet, Makrem; Fnaiech, Farhat
2018-01-01
A new control system of a hand gesture-controlled wheelchair (EWC) is proposed. This smart control device is suitable for a large number of patients who cannot manipulate a standard joystick wheelchair. The movement control system uses a camera fixed on the wheelchair. The patient's hand movements are recognized using a visual recognition algorithm and artificial intelligence software; the derived corresponding signals are thus used to control the EWC in real time. One of the main features of this control technique is that it allows the patient to drive the wheelchair with a variable speed similar to that of a standard joystick. The designed device “hand gesture-controlled wheelchair” is performed at low cost and has been tested on real patients and exhibits good results. Before testing the proposed control device, we have created a three-dimensional environment simulator to test its performances with extreme security. These tests were performed on real patients with diverse hand pathologies in Mohamed Kassab National Institute of Orthopedics, Physical and Functional Rehabilitation Hospital of Tunis, and the validity of this intelligent control system had been proved. PMID:29599953
NASA Technical Reports Server (NTRS)
Weick, Fred E; Noyes, Richard W
1936-01-01
This is the thirteenth report on a series of systematic tests comparing lateral control devices with particular reference to their effectiveness at high angles of attack. The present wind tunnel tests were made to determine the most feasible locations for lateral control surfaces mounted externally to a rectangular Clark y wing.
21 CFR 884.6150 - Assisted reproduction micromanipulators and microinjectors.
Code of Federal Regulations, 2011 CFR
2011-04-01
... controls) (design specifications, labeling requirements, and clinical testing). .... Assisted reproduction micromanipulators are devices intended to control the position of an assisted reproduction microtool. Assisted reproduction microinjectors are any device intended to control aspiration or...
21 CFR 884.6150 - Assisted reproduction micromanipulators and microinjectors.
Code of Federal Regulations, 2013 CFR
2013-04-01
... controls) (design specifications, labeling requirements, and clinical testing). .... Assisted reproduction micromanipulators are devices intended to control the position of an assisted reproduction microtool. Assisted reproduction microinjectors are any device intended to control aspiration or...
21 CFR 884.6150 - Assisted reproduction micromanipulators and microinjectors.
Code of Federal Regulations, 2010 CFR
2010-04-01
... controls) (design specifications, labeling requirements, and clinical testing). .... Assisted reproduction micromanipulators are devices intended to control the position of an assisted reproduction microtool. Assisted reproduction microinjectors are any device intended to control aspiration or...
21 CFR 884.6150 - Assisted reproduction micromanipulators and microinjectors.
Code of Federal Regulations, 2012 CFR
2012-04-01
... controls) (design specifications, labeling requirements, and clinical testing). .... Assisted reproduction micromanipulators are devices intended to control the position of an assisted reproduction microtool. Assisted reproduction microinjectors are any device intended to control aspiration or...
21 CFR 884.6150 - Assisted reproduction micromanipulators and microinjectors.
Code of Federal Regulations, 2014 CFR
2014-04-01
... controls) (design specifications, labeling requirements, and clinical testing). .... Assisted reproduction micromanipulators are devices intended to control the position of an assisted reproduction microtool. Assisted reproduction microinjectors are any device intended to control aspiration or...
Color vision deficits and laser eyewear protection for soft tissue laser applications.
Teichman, J M; Vassar, G J; Yates, J T; Angle, B N; Johnson, A J; Dirks, M S; Thompson, I M
1999-03-01
Laser safety considerations require urologists to wear laser eye protection. Laser eye protection devices block transmittance of specific light wavelengths and may distort color perception. We tested whether urologists risk color confusion when wearing laser eye protection devices for laser soft tissue applications. Subjects were tested with the Farnsworth-Munsell 100-Hue Test without (controls) and with laser eye protection devices for carbon dioxide, potassium titanyl phosphate (KTP), neodymium (Nd):YAG and holmium:YAG lasers. Color deficits were characterized by error scores, polar graphs, confusion angles, confusion index, scatter index and color axes. Laser eye protection device spectral transmittance was tested with spectrophotometry. Mean total error scores plus or minus standard deviation were 13+/-5 for controls, and 44+/-31 for carbon dioxide, 273+/-26 for KTP, 22+/-6 for Nd:YAG and 14+/-8 for holmium:YAG devices (p <0.001). The KTP laser eye protection polar graphs, and confusion and scatter indexes revealed moderate blue-yellow and red-green color confusion. Color axes indicated no significant deficits for controls, or carbon dioxide, Nd:YAG or holmium:YAG laser eye protection in any subject compared to blue-yellow color vision deficits in 8 of 8 tested with KTP laser eye protection (p <0.001). Spectrophotometry demonstrated that light was blocked with laser eye protection devices for carbon dioxide less than 380, holmium:YAG greater than 850, Nd:YAG less than 350 and greater than 950, and KTP less than 550 and greater than 750 nm. The laser eye protection device for KTP causes significant blue-yellow and red-green color confusion. Laser eye protection devices for carbon dioxide, holmium:YAG and Nd:YAG cause no significant color confusion compared to controls. The differences are explained by laser eye protection spectrophotometry characteristics and visual physiology.
A Mechanomodulatory Device to Minimize Incisional Scar Formation
Wong, Victor W.; Beasley, Bill; Zepeda, John; Dauskardt, Reinhold H.; Yock, Paul G.; Longaker, Michael T.; Gurtner, Geoffrey C.
2013-01-01
Objective To mechanically control the wound environment and prevent cutaneous scar formation. Approach We subjected various material substrates to biomechanical testing to investigate their ability to modulate skin behavior. Combinations of elastomeric materials, adhesives, and strain applicators were evaluated to develop topical stress-shielding devices. Noninvasive imaging modalities were utilized to characterize anatomic site-specific differences in skin biomechanical properties in humans. The devices were tested in a validated large animal model of hypertrophic scarring. Phase I within-patient controlled clinical trials were conducted to confirm their safety and efficacy in scar reduction in patients undergoing abdominoplasty surgery. Results Among the tested materials and device applicators, a polymer device was developed that effectively off-loaded high tension wounds and blocked pro-fibrotic pathways and excess scar formation in red Duroc swine. In humans, different anatomic sites exhibit unique biomechanical properties that may correlate with the propensity to form scars. In the clinical trial, utilization of this device significantly reduced incisional scar formation and improved scar appearance for up to 12 months compared with control incisions that underwent routine postoperative care. Innovation This is the first device that is able to precisely control the mechanical environment of incisional wounds and has been demonstrated in multiple clinical trials to significantly reduce scar formation after surgery. Conclusion Mechanomodulatory strategies to control the incisional wound environment can significantly reduce pathologic scarring and fibrosis after surgery. PMID:24527342
Screening of Potential Landing Gear Noise Control Devices at Virginia Tech For QTD II Flight Test
NASA Technical Reports Server (NTRS)
Ravetta, Patricio A.; Burdisso, Ricardo A.; Ng, Wing F.; Khorrami, Mehdi R.; Stoker, Robert W.
2007-01-01
In support of the QTD II (Quiet Technology Demonstrator) program, aeroacoustic measurements of a 26%-scale, Boeing 777 main landing gear model were conducted in the Virginia Tech Stability Tunnel. The objective of these measurements was to perform risk mitigation studies on noise control devices for a flight test performed at Glasgow, Montana in 2005. The noise control devices were designed to target the primary main gear noise sources as observed in several previous tests. To accomplish this task, devices to reduce noise were built using stereo lithography for landing gear components such as the brakes, the forward cable harness, the shock strut, the door/strut gap and the lower truck. The most promising device was down selected from test results. In subsequent stages, the initial design of the selected lower truck fairing was improved to account for all the implementation constraints encountered in the full-scale airplane. The redesigned truck fairing was then retested to assess the impact of the modifications on the noise reduction potential. From extensive acoustic measurements obtained using a 63-element microphone phased array, acoustic source maps and integrated spectra were generated in order to estimate the noise reduction achievable with each device.
Control and Visualization of a Shear Layer Over a Weapons Bay
NASA Astrophysics Data System (ADS)
Schmit, Ryan; Raman, Ganesh; Lourenco, Luis; Kibens, Valdis
2005-11-01
In July 2005, the AFRL program Flow Control Analysis Development (FlowCAD) tested the High Frequency Excitation Active Flow Control for Supersonic Weapons Release (HIFEX) generic weapons bay model in the Boeing's Polysonic windtunnel facility. The 10% scaled weapons bay with an L/D of 5 was tested at Mach 1.82. Several flow control devices were tested, including: the goalpost, a wedge and pin configuration, and the splash jet, to determine their effectiveness at reducing the sound pressure levels inside the weapons bay. The results show the wedge and splash jet are equally effective at reducing the peak Rossiter tone by 20 dB. The main objective of this test was to visualize the shear layer over the weapons bay cavity. By examining the cavity shear layer with a 10 kHz Focused Schlieren system the effects from the flow control devices can be understood to produce a more effective flow control device in the future.
21 CFR 862.1575 - Phospholipid test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862... treatment of disorders involving lipid (fat) metabolism. (b) Classification. Class I (general controls). The...
Code of Federal Regulations, 2013 CFR
2013-07-01
... system and add-on control device operating limits during the performance test? 63.3546 Section 63.3546... of key parameters of the valve operating system (e.g., solenoid valve operation, air pressure... minimum operating limit for that specific capture device or system of multiple capture devices. The...
Code of Federal Regulations, 2014 CFR
2014-07-01
... capture system and add-on control device operating limits during the performance test? 63.3546 Section 63... of key parameters of the valve operating system (e.g., solenoid valve operation, air pressure... minimum operating limit for that specific capture device or system of multiple capture devices. The...
Code of Federal Regulations, 2012 CFR
2012-07-01
... capture system and add-on control device operating limits during the performance test? 63.3546 Section 63... of key parameters of the valve operating system (e.g., solenoid valve operation, air pressure... minimum operating limit for that specific capture device or system of multiple capture devices. The...
Testing methods and techniques: Testing electrical and electronic devices: A compilation
NASA Technical Reports Server (NTRS)
1972-01-01
The methods, techniques, and devices used in testing various electrical and electronic apparatus are presented. The items described range from semiconductor package leak detectors to automatic circuit analyzer and antenna simulators for system checkout. In many cases the approaches can result in considerable cost savings and improved quality control. The testing of various electronic components, assemblies, and systems; the testing of various electrical devices; and the testing of cables and connectors are explained.
STS-43 Commander Blaha conducts DTO 1208 using laptop on OV-104's flight deck
1991-08-11
STS043-03-009 (5 Aug 1991) ---- Astronaut John E. Blaha is pictured executing development test objective (DTO) 1208, Space Station Cursor Control Device Evaluation II and advanced applications. The purpose of the Cursor Control Device Experiment is to evaluate human performance under space flight conditions of cursor control devices which are similar to the devices under consideration for use onboard Space Station computers. Here, the mission commander uses a thumbball/handgrip control device. Each crewmember evaluated the different types of cursor control devices during the nine-day STS-43 mission. Other methods of cursor control evaluated were the built-in trackball, a side mounted trackball with restraints and an optical pad with mouse.
STS-43 MS Adamson conducts DTO 1208 using laptop on OV-104's flight deck
1991-08-11
STS043-14-034 (2-11 Aug 1991) --- Astronaut James C. Adamson is pictured executing Development Test Objective (DTO) 1208, Space Station Cursor Control Device Evaluation II and Advanced Applications. The purpose of the Cursor Control Device Experiment is to evaluate human performance under space flight conditions of cursor control devices which are similar to the devices under consideration for use onboard space station computers. Here, the mission specialists uses a thumbball/handgrip control device. Each crewmember evaluated the different types of cursor control devices during the nine-day STS-43 mission. Other methods of cursor control evaluated were the built-in trackball, a side mounted trackball with restraints and an optical pad with mouse.
Accuracy of torque-limiting devices: A comparative evaluation.
Albayrak, Haydar; Gumus, Hasan Onder; Tursun, Funda; Kocaagaoglu, Hasan Huseyin; Kilinc, Halil Ibrahim
2017-01-01
To prevent the loosening of implant screws, clinicians should be aware of the output torque values needed to achieve the desired preload. Accurate torque-control devices are crucial in this regard; however, little information is currently available comparing the accuracy of mechanical with that of electronic torque-control devices. The purpose of this in vitro study was to identify and compare the accuracy of different types of torque-control devices. Devices from 5 different dental implant manufacturers were evaluated, including 2 spring-type (Straumann, Implance) mechanical devices (MTLD), 2 friction-type (Biohorizons, Dyna) MTLDs, and 1 (Megagen) electronic torque-control device (ETLD). For each manufacturer, 5 devices were tested 5 times with a digital torque tester, and the average for each device was calculated and recorded. The percentage of absolute deviations from the target torque values (PERDEV) were calculated and compared by using 1-way ANOVA. A 1-sample t test was used to evaluate the ability of each device to achieve its target torque value within a 95% confidence interval for the true population mean of measured values (α=.05 for all statistical analyses). One-way ANOVAs revealed statistically significant differences among torque-control devices (P<.001). ETLD showed higher PERDEVs (28.33 ±9.53) than MTLDs (P<.05), whereas PERDEVS of friction-type (7.56 ±3.64) and spring-type (10.85 ±4.11) MTLDs did not differ significantly. In addition, devices produced by Megagen had a significantly higher (P<.05) PERDEV (28.33 ±9.53) other devices, whereas no differences were found in devices manufactured by Biohorizons (7.31 ±5.34), Dyna (7.82 ±1.08), Implance (8.43 ±4.77), and Straumann (13.26 ±0.79). However, 1-sample t tests showed none of the torque-control devices evaluated in this study were capable of achieving their target torque values (P<.05). Within the limitations of this in vitro study, MTLDs were shown to be significantly more accurate than ETLDs. However, none of the torque-control devices evaluated were able to meet their target torque values successfully. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
21 CFR 862.1550 - Urinary pH (nonquantitative) test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test... the monitoring of patients with certain diets. (b) Classification. Class I (general controls). The...
21 CFR 862.1815 - Vitamin E test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862... treatment of infants with vitamin E deficiency syndrome. (b) Classification. Class I (general controls). The...
NASA Astrophysics Data System (ADS)
Trenbath, Kim; Hannigan, Michael P.; Milford, Jana B.
2009-12-01
This study evaluates the effect of retrofit closed crankcase ventilation filters (CCFs) and diesel oxidation catalysts (DOCs) on the in-cabin air quality in transit-style diesel school buses. In-cabin pollution levels were measured on three buses from the Pueblo, CO District 70 fleet. Monitoring was conducted while buses were driven along their regular routes, with each bus tested three times before and three times after installation of control devices. Ultrafine number concentrations in the school bus cabins were 33-41% lower, on average, after the control devices were installed. Mean mass concentrations of particulate matter less than 2.5 μm in diameter (PM2.5) were 56% lower, organic carbon (OC) 41% lower, elemental carbon (EC) 85% lower, and formaldehyde 32% lower after control devices were installed. While carbon monoxide concentrations were low in all tests, mean concentrations were higher after control devices were installed than in pre-retrofit tests. Reductions in number, OC, and formaldehyde concentrations were statistically significant, but reductions in PM2.5 mass were not. Even with control devices installed, during some runs PM2.5 and OC concentrations in the bus cabins were elevated compared to ambient concentrations observed in the area. OC concentrations inside the bus cabins ranged from 22 to 58 μg m -3 before and 13 to 33 μg m -3 after control devices were installed. OC concentrations were correlated with particle-bound organic tracers for lubricating oil emissions (hopanes) and diesel fuel and tailpipe emissions (polycyclic aromatic hydrocarbons (PAH) and aliphatic hydrocarbons). Mean concentrations of hopanes, PAH, and aliphatic hydrocarbons were lower by 37, 50, and 43%, respectively, after the control devices were installed, suggesting that both CCFs and DOCs were effective at reducing in-cabin OC concentrations.
21 CFR 862.3280 - Clinical toxicology control material.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Clinical toxicology control material. 862.3280... (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862.3280 Clinical toxicology control material. (a) Identification. A clinical toxicology control...
21 CFR 862.3280 - Clinical toxicology control material.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Clinical toxicology control material. 862.3280... (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862.3280 Clinical toxicology control material. (a) Identification. A clinical toxicology control...
21 CFR 862.3280 - Clinical toxicology control material.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Clinical toxicology control material. 862.3280... (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862.3280 Clinical toxicology control material. (a) Identification. A clinical toxicology control...
21 CFR 862.3280 - Clinical toxicology control material.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Clinical toxicology control material. 862.3280... (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862.3280 Clinical toxicology control material. (a) Identification. A clinical toxicology control...
21 CFR 862.3280 - Clinical toxicology control material.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Clinical toxicology control material. 862.3280... (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862.3280 Clinical toxicology control material. (a) Identification. A clinical toxicology control...
Evaluating the effectiveness of biometric access control systems
NASA Astrophysics Data System (ADS)
Lively, Valerie M.
2005-05-01
This paper describes the contribution by the National Safe Skies Alliance (Safe Skies) in operational testing of biometric access control systems under the guidance of the Transportation Security Administration (TSA). Safe Skies has been conducting operational tests of biometric access control systems on behalf of the TSA for approximately four years. The majority of this testing has occurred at the McGhee Tyson Airport (TYS) in Knoxville, Tennessee. Twelve separate biometric devices - eight fingerprint, facial, iris, hand geometry, and fingerprint and iris, have been tested to date. Tests were conducted at a TYS administrative door and different airports to evaluate the access control device under normal, abnormal, and attempt-to-defeat conditions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... capture system and add-on control device operating limits during the performance test? 63.9324 Section 63... Requirements § 63.9324 How do I establish the emission capture system and add-on control device operating... the operating limits required by § 63.9302 according to this section, unless you have received...
Code of Federal Regulations, 2012 CFR
2012-07-01
... capture system and add-on control device operating limits during the performance test? 63.9324 Section 63... Requirements § 63.9324 How do I establish the emission capture system and add-on control device operating... the operating limits required by § 63.9302 according to this section, unless you have received...
Code of Federal Regulations, 2013 CFR
2013-07-01
... capture system and add-on control device operating limits during the performance test? 63.9324 Section 63... Requirements § 63.9324 How do I establish the emission capture system and add-on control device operating... the operating limits required by § 63.9302 according to this section, unless you have received...
Code of Federal Regulations, 2014 CFR
2014-07-01
... capture system and add-on control device operating limits during the performance test? 63.9324 Section 63... Requirements § 63.9324 How do I establish the emission capture system and add-on control device operating... the operating limits required by § 63.9302 according to this section, unless you have received...
Code of Federal Regulations, 2011 CFR
2011-07-01
... capture system and add-on control device operating limits during the performance test? 63.9324 Section 63... Requirements § 63.9324 How do I establish the emission capture system and add-on control device operating... the operating limits required by § 63.9302 according to this section, unless you have received...
Laser Ignition Device and Its Application to Forestry, Fire and Land Management
Michael D. Waterworth
1987-01-01
A laser ignition device for controlled burning of forest logging slash has been developed and successfully tested. The device, which uses a kilowatt class carbon dioxide laser, operates at distances of 50 to 1500 meters. Acquisition and focus control are achieved by the use of a laser rangefinder and acquisition telescope. Additional uses for the device include back...
Determining Desirable Cursor Control Device Characteristics for NASA Exploration Missions
NASA Technical Reports Server (NTRS)
Sandor, Aniko; Holden, Kritina
2007-01-01
The Crew Exploration Vehicle (CEV) that will travel to the moon and Mars, and all future Exploration vehicles and habitats will be highly computerized, necessitating an accurate method of interaction with the computers. The design of a cursor control device will have to take into consideration g-forces, vibration, gloved operations, and the specific types of tasks to be performed. The study described here is being undertaken to begin identifying characteristics of cursor control devices that will work well for the unique Exploration mission environments. The objective of the study is not to identify a particular device, but to begin identifying design characteristics that are usable and desirable for space missions. Most cursor control devices have strengths and weaknesses; they are more appropriate for some tasks and less suitable for others. The purpose of this study is to collect some initial usability data on a large number of commercially available and proprietary cursor control devices. A software test battery was developed for this purpose. Once data has been collected using these low-level, basic point/click/drag tasks, higher fidelity, scenario-driven evaluations will be conducted with a reduced set of devices. The standard tasks used for testing cursor control devices are based on a model of human movement known as Fitts law. Fitts law predicts that the time to acquire a target is logarithmically related to the distance over the target size. To gather data for analysis with this law, fundamental, low-level tasks are used such as dragging or pointing at various targets of different sizes from various distances. The first four core tasks for the study were based on the ISO 9241-9:(2000) document from the International Organization for Standardization that contains the requirements for non-keyboard input devices. These include two pointing tasks, one dragging and one tracking task. The fifth task from ISO 9241-9, the circular tracking task was not used because it is a movement that is not applicable to most of the applications used on aviation displays. Additionally, we opted to add a multi-size and multi-distance pointing task, and two ecologically more valid tasks which included text selection, and interaction with drop down menus, sliders, and checkboxes. The Visual Basic test battery tracks the task and trial numbers, measures the pointing, tracking or dragging time, as well as the number and types of errors. The testing session includes a practice set for each input device, then the randomized 7 tasks, and finally a questionnaire about the device. This is repeated for all the devices tested within a session. The experiment is a within-subjects design, with participants returning for multiple sessions to test additional devices. The input devices will be compared based on objective performance data from the tasks, as well as subjective feedback and ratings on the questionnaire.
Hand controller commonality evaluation process
NASA Technical Reports Server (NTRS)
Stuart, Mark A.; Bierschwale, John M.; Wilmington, Robert P.; Adam, Susan C.; Diaz, Manuel F.; Jensen, Dean G.
1990-01-01
A hand controller evaluation process has been developed to determine the appropriate hand controller configurations for supporting remotely controlled devices. These devices include remote manipulator systems (RMS), dexterous robots, and remotely-piloted free flyers. Standard interfaces were developed to evaluate six different hand controllers in three test facilities including dynamic computer simulations, kinematic computer simulations, and physical simulations. The hand controllers under consideration were six degree-of-freedom (DOF) position and rate minimaster and joystick controllers, and three-DOF rate controllers. Task performance data, subjective comments, and anthropometric data obtained during tests were used for controller configuration recommendations to the SSF Program.
NASA Technical Reports Server (NTRS)
Weick, Fred E; Wenzinger, Carl J
1933-01-01
Tests were made with ordinary ailerons and different sizes of spoilers on rectangular Clark Y wing models with Handley Page tip and full span slots. The tests showed the effect of the control devices on the general performance of the wings as well as on the lateral control and lateral stability characteristics.
21 CFR 862.1360 - Gamma-glutamyl transpeptidase and isoenzymes test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862.1360 Gamma-glutamyl transpeptidase and isoenzymes test system. (a... alcoholic cirrhosis and primary and secondary liver tumors. (b) Classification. Class I (general controls...
21 CFR 862.1365 - Glutathione test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
....1365 Glutathione test system. (a) Identification. A glutathione test system is a device intended to measure glutathione (the tripeptide of glycine, cysteine, and glutamic acid) in erythrocytes (red blood... I (general controls). The device is exempt from the premarket notification procedures in subpart E...
21 CFR 862.1365 - Glutathione test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
....1365 Glutathione test system. (a) Identification. A glutathione test system is a device intended to measure glutathione (the tripeptide of glycine, cysteine, and glutamic acid) in erythrocytes (red blood... I (general controls). The device is exempt from the premarket notification procedures in subpart E...
21 CFR 862.1365 - Glutathione test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
....1365 Glutathione test system. (a) Identification. A glutathione test system is a device intended to measure glutathione (the tripeptide of glycine, cysteine, and glutamic acid) in erythrocytes (red blood... I (general controls). The device is exempt from the premarket notification procedures in subpart E...
Membrane Based Thermal Control Development
NASA Technical Reports Server (NTRS)
Murdoch, Karen
1997-01-01
The investigation of the feasibility of using a membrane device as a water boiler for thermal control is reported. The membrane device permits water vapor to escape to the vacuum of space but prevents the loss of liquid water. The vaporization of the water provides cooling to the water loop. This type of cooling device would have application for various types of short duration cooling needs where expenditure of water is allowed and a low pressure source is available such as in space or on a planet's surface. A variety of membrane samples, both hydrophilic and hydrophobic, were purchased to test for this thermal control application. An initial screening test determined if the membrane could pose a sufficient barrier to maintain water against vacuum. Further testing compared the heat transfer performance of those membranes that passed the screening test.
NASA Astrophysics Data System (ADS)
Gallasch, Eugen; Kozlovskaya, Inessa
2007-02-01
Long term space flights induce atrophy and contractile changes on postural muscles such effecting tonic motor control. Functional testing of tonic motor control structures is a challenge because of the difficulties to deliver appropriate test forces on crew members. In this paper we propose two approaches for functional testing by using limb attached loading devices. The first approach is based on a frequency and amplitude controllable moving magnet exciter to deliver sinusoidal test forces during limb postures. The responding limb deflection is recorded by an embedded accelerometer to obtain limb impedance. The second approach is based on elastic limb loading to evoke self-excited oscillations during arm extensions. Here the contraction force at the oscillation onset provides information about limb stiffness. The rationale for both testing approaches is based on Feldman's λ-model. An arm expander based on the second approach was probed in a 6-month MIR space flight. The results obtained from the load oscillations, confirmed that this device is well suited to capture space flight induced neuromuscular changes.
An automated testing tool for traffic signal controller functionalities.
DOT National Transportation Integrated Search
2010-03-01
The purpose of this project was to develop an automated tool that facilitates testing of traffic controller functionality using controller interface device (CID) technology. Benefits of such automated testers to traffic engineers include reduced test...
Code of Federal Regulations, 2014 CFR
2014-07-01
... percent oxygen as determined in accordance with the requirements of § 60.5413. (iii) You must operate at a... requirements of § 60.5415(b)(2), as applicable. (c) For each carbon adsorption system used as a control device... (a)(1) through (3) of this section. As an alternative, you may install a control device model tested...
Method and system for automated on-chip material and structural certification of MEMS devices
Sinclair, Michael B.; DeBoer, Maarten P.; Smith, Norman F.; Jensen, Brian D.; Miller, Samuel L.
2003-05-20
A new approach toward MEMS quality control and materials characterization is provided by a combined test structure measurement and mechanical response modeling approach. Simple test structures are cofabricated with the MEMS devices being produced. These test structures are designed to isolate certain types of physical response, so that measurement of their behavior under applied stress can be easily interpreted as quality control and material properties information.
21 CFR 864.6600 - Osmotic fragility test.
Code of Federal Regulations, 2011 CFR
2011-04-01
... test. (a) Identification. An osmotic fragility test is a device used to determine the resistance of red blood cells to hemolysis (destruction) in varying concentrations of hypotonic saline solutions. (b) Classification. Class I (general controls). This device is exempt from the premarket notification procedures in...
21 CFR 864.6600 - Osmotic fragility test.
Code of Federal Regulations, 2012 CFR
2012-04-01
... test. (a) Identification. An osmotic fragility test is a device used to determine the resistance of red blood cells to hemolysis (destruction) in varying concentrations of hypotonic saline solutions. (b) Classification. Class I (general controls). This device is exempt from the premarket notification procedures in...
21 CFR 864.6600 - Osmotic fragility test.
Code of Federal Regulations, 2014 CFR
2014-04-01
... test. (a) Identification. An osmotic fragility test is a device used to determine the resistance of red blood cells to hemolysis (destruction) in varying concentrations of hypotonic saline solutions. (b) Classification. Class I (general controls). This device is exempt from the premarket notification procedures in...
21 CFR 864.6600 - Osmotic fragility test.
Code of Federal Regulations, 2013 CFR
2013-04-01
... test. (a) Identification. An osmotic fragility test is a device used to determine the resistance of red blood cells to hemolysis (destruction) in varying concentrations of hypotonic saline solutions. (b) Classification. Class I (general controls). This device is exempt from the premarket notification procedures in...
21 CFR 864.6600 - Osmotic fragility test.
Code of Federal Regulations, 2010 CFR
2010-04-01
... test. (a) Identification. An osmotic fragility test is a device used to determine the resistance of red blood cells to hemolysis (destruction) in varying concentrations of hypotonic saline solutions. (b) Classification. Class I (general controls). This device is exempt from the premarket notification procedures in...
LEO Flight Testing of GaAs on Si Solar Cells Aboard MISSES
NASA Technical Reports Server (NTRS)
Wilt, David M.; Clark, Eric B.; Ringel, Steven A.; Andre, Carrie L.; Smith, Mark A.; Scheiman, David A.; Jenkins, Phillip P.; Maurer, William F.; Fitzgerald, Eugene A.; Walters, R. J.
2004-01-01
Previous research efforts have demonstrated small area (0.04 cm) GaAs on Si (GaAs/Si) solar cells with AM0 efficiencies in excess of 17%. These results were achieved on Si substrates coated with a step graded buffer of Si(x),Ge(1-x) alloys graded to 100% Ge. Recently, a 100-fold increase in device area was accomplished for these devices in preparation for on-orbit testing of this technology aboard Materials International Space Station Experiment number 5 (MISSE5). The GaAs/Si MISSE5 experiment contains five (5) GaAs/Si test devices with areas of lcm(exp 2) and 4cm(exp 4) as well as two (2) GaAs on GaAs control devices. Electrical performance data, measured on-orbit for three (3) of the test devices and one (1) of the control devices, will be telemetered to ground stations daily. After approximately one year on orbit, the MISSE5 payload will be returned to Earth for post flight evaluation. This paper will discuss the development of the GaAs/Si devices for the MISSE5 flight experiment and will present recent ground and on-orbit performance data.
Fabrication and test of digital output interface devices for gas turbine electronic controls
NASA Technical Reports Server (NTRS)
Newirth, D. M.; Koenig, E. W.
1978-01-01
A program was conducted to develop an innovative digital output interface device, a digital effector with optical feedback of the fuel metering valve position, for future electronic controls for gas turbine engines. A digital effector (on-off solenoids driven directly by on-off signals from a digital electronic controller) with optical position feedback was fabricated, coupled with the fuel metering valve, and tested under simulated engine operating conditions. The testing indicated that a digital effector with optical position feedback is a suitable candidate, with proper development for future digital electronic gas turbine controls. The testing also identified several problem areas which would have to be overcome in a final production configuration.
Wind Tunnel Test of an RPV with Shape-Change Control Effector and Sensor Arrays
NASA Technical Reports Server (NTRS)
Raney, David L.; Cabell, Randolph H.; Sloan, Adam R.; Barnwell, William G.; Lion, S. Todd; Hautamaki, Bret A.
2004-01-01
A variety of novel control effector concepts have recently emerged that may enable new approaches to flight control. In particular, the potential exists to shift the composition of the typical aircraft control effector suite from a small number of high authority, specialized devices (rudder, aileron, elevator, flaps), toward larger numbers of smaller, less specialized, distributed device arrays. The concept envisions effector and sensor networks composed of relatively small high-bandwidth devices able to simultaneously perform a variety of control functions using feedback from disparate data sources. To investigate this concept, a remotely piloted flight vehicle has been equipped with an array of 24 trailing edge shape-change effectors and associated pressure measurements. The vehicle, called the Multifunctional Effector and Sensor Array (MESA) testbed, was recently tested in NASA Langley's 12-ft Low Speed wind tunnel to characterize its stability properties, control authorities, and distributed pressure sensitivities for use in a dynamic simulation prior to flight testing. Another objective was to implement and evaluate a scheme for actively controlling the spanwise pressure distribution using the shape-change array. This report describes the MESA testbed, design of the pressure distribution controller, and results of the wind tunnel test.
Electromechanically Actuated Multifunctional Wireless Auxetic Device for Wound Management.
Mir, Mariam; Ansari, Umar; Ali, Murtaza Najabat; Iftikhar, Muhammad Hassan Ul; Qayyum, Faisal
2017-01-01
The design and fabrication of a wound healing device for chronic wounds, with multiple functions for controlled drug delivery and exudate removal, has been described in this paper. The structural features have been machined and modified through laser cutting in a biocompatible polymer cast. Miniaturized versions of electronically actuated (lead-screw and pulley) mechanisms are used for the specific purpose of controlled drug delivery. These mechanisms have been studied and tested, being controlled through a microcontroller setup. An auxetic polymeric barrier membrane has been used for restricting the drug quantities administered. Drug delivery mechanisms are powered wirelessly, through an external, active RF component; this communicates with a passive component that is buried inside the wound healing device. The exudate removal efficiency of the device has been assessed through several simple tests using simulated wound exudate. It has been found that reasonably precise quantities of drug dosages to be administered to the wound site can be controlled through both drug delivery mechanisms; however, the lead-screw mechanism provides a better control of auxetic barrier membrane actuation and hence controlled drug delivery. We propose that this device can have potential clinical significance in controlled drug delivery and exudate removal in the management of chronic wounds.
Bibbs, Christopher S; Fulcher, Ali; Xue, Rui-De
2015-07-01
A mosquito control device marketed for spatial repellency, the ThermaCELL Mosquito Repellent Appliance, was evaluated in semifield trials against multiple field-caught species of mosquito. Using paper and mesh cages, mosquito test groups of at least 30 mosquitoes were suspended in a 2,337 cubic foot outdoor space while two ThermaCELL repellent devices were active. After 30 min of treatment, cages were moved to the laboratory to observe knockdown, morbidity, and mortality for 24 h. Species tested included Aedes atlanticus Dyar and Knab (98% average mortality), Psorophora ferox Humboldt (97% average mortality), Psorophora columbiae Dyar and Knab (96% average mortality), and Aedes taeniorhynchus Wiedemann (84% average mortality). The repellent devices showed effectiveness with high knockdown and mortality across all species tested. Mosquito control devices like the ThermaCELL Mosquito Repellent Appliance may have further practical applications to help combat viral exposures by limiting host mosquitoes. Such devices may provide a functional alternative to DEET dependence in the current state of mosquito management. © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
21 CFR 862.1670 - Sorbitol dehydrogenase test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Systems § 862.1670 Sorbitol dehydrogenase test system. (a) Identification. A sorbitol dehydrogenase test system is a device intended to measure the activity of the enzyme sorbitol dehydrogenase in serum... cirrhosis or acute hepatitis. (b) Classification. Class I (general controls). The device is exempt from the...
21 CFR 866.5490 - Hemopexin immunological test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... survival of mature red blood cells and inability of the bone marrow to compensate for their decreased life span) and sickle cell anemia. (b) Classification. Class II (special controls). The device is exempt... Hemopexin immunological test system. (a) Indentification. A hemopexin immunological test system is a device...
21 CFR 866.5490 - Hemopexin immunological test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... survival of mature red blood cells and inability of the bone marrow to compensate for their decreased life span) and sickle cell anemia. (b) Classification. Class II (special controls). The device is exempt... Hemopexin immunological test system. (a) Indentification. A hemopexin immunological test system is a device...
21 CFR 866.5490 - Hemopexin immunological test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... survival of mature red blood cells and inability of the bone marrow to compensate for their decreased life span) and sickle cell anemia. (b) Classification. Class II (special controls). The device is exempt... Hemopexin immunological test system. (a) Indentification. A hemopexin immunological test system is a device...
21 CFR 866.5490 - Hemopexin immunological test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... survival of mature red blood cells and inability of the bone marrow to compensate for their decreased life span) and sickle cell anemia. (b) Classification. Class II (special controls). The device is exempt... Hemopexin immunological test system. (a) Indentification. A hemopexin immunological test system is a device...
NASA Technical Reports Server (NTRS)
Alhorn, D. C.; Polites, M. E.
1994-01-01
Rotating unbalanced-mass (RUM) devices are a new way to scan space-based, balloon-borne, and ground-based gimbaled payloads, like x-ray and gamma-ray telescopes. They can also be used to scan free-flying spacecraft. Circular scans, linear scans, and raster scans can be generated. A pair of RUM devices generates the basic scan motion and an auxiliary control system using torque motors, control moment gyros, or reaction wheels keeps the scan centered on the target and produces some complementary motion for raster scanning. Previous analyses and simulation results show that this approach offers significant power savings compared to scanning only with the auxiliary control system, especially with large payloads and high scan frequencies. However, these claims have never been proven until now. This paper describes a laboratory experiment which tests the concept of scanning a gimbaled payload with RUM devices. A description of the experiment is given and test results that prove the concept are presented. The test results are compared with those from a computer simulation model of the experiment and the differences are discussed.
21 CFR 864.7675 - Leukocyte peroxidase test.
Code of Federal Regulations, 2011 CFR
2011-04-01
... cells of the lymphatic system and erythroid cells of the red blood cell series on the basis of their... peroxidase test. (a) Identification. A leukocyte peroxidase test is a device used to distinguish certain... of the leukemias. (b) Classification. Class I (general controls). This device is exempt from the...
21 CFR 864.7675 - Leukocyte peroxidase test.
Code of Federal Regulations, 2013 CFR
2013-04-01
... cells of the lymphatic system and erythroid cells of the red blood cell series on the basis of their... peroxidase test. (a) Identification. A leukocyte peroxidase test is a device used to distinguish certain... of the leukemias. (b) Classification. Class I (general controls). This device is exempt from the...
21 CFR 864.7675 - Leukocyte peroxidase test.
Code of Federal Regulations, 2012 CFR
2012-04-01
... cells of the lymphatic system and erythroid cells of the red blood cell series on the basis of their... peroxidase test. (a) Identification. A leukocyte peroxidase test is a device used to distinguish certain... of the leukemias. (b) Classification. Class I (general controls). This device is exempt from the...
21 CFR 864.7675 - Leukocyte peroxidase test.
Code of Federal Regulations, 2010 CFR
2010-04-01
... cells of the lymphatic system and erythroid cells of the red blood cell series on the basis of their... peroxidase test. (a) Identification. A leukocyte peroxidase test is a device used to distinguish certain... of the leukemias. (b) Classification. Class I (general controls). This device is exempt from the...
21 CFR 864.7675 - Leukocyte peroxidase test.
Code of Federal Regulations, 2014 CFR
2014-04-01
... cells of the lymphatic system and erythroid cells of the red blood cell series on the basis of their... peroxidase test. (a) Identification. A leukocyte peroxidase test is a device used to distinguish certain... of the leukemias. (b) Classification. Class I (general controls). This device is exempt from the...
Code of Federal Regulations, 2011 CFR
2011-07-01
... device emission destruction or removal efficiency? 63.4965 Section 63.4965 Protection of Environment....4965 How do I determine the add-on control device emission destruction or removal efficiency? You must... destruction or removal efficiency as part of the performance test required by § 63.4960. You must conduct...
40 CFR 65.158 - Performance test procedures for control devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... simultaneously from multiple loading arms, each run shall represent at least one complete tank truck or tank car... the combustion air or as a secondary fuel into a boiler or process heater with a design capacity less... corrected to 3 percent oxygen if a combustion device is the control device. (A) The emission rate correction...
NASA Astrophysics Data System (ADS)
Mahalder, B.; Schwartz, J. S.; Palomino, A.; Papanicolaou, T.
2016-12-01
Cohesive soil erodibility and threshold shear stress for stream bed and bank are dependent on both soil physical and geochemical properties in association with the channel vegetative conditions. These properties can be spatially variable therefore making critical shear stress measurement in cohesive soil challenging and leads to a need for a more comprehensive understanding of the erosional processes in streams. Several in-situ and flume-type test devices for estimating critical shear stress have been introduced by different researchers; however reported shear stress estimates per device vary widely in orders of magnitude. Advantages and disadvantages exist between these devices. Development of in-situ test devices leave the bed and/or bank material relatively undisturbed and can capture the variable nature of field soil conditions. However, laboratory flumes provide a means to control environmental conditions that can be quantify and tested. This study was conducted to observe differences in critical shear stress using jet tester and a well-controlled conduit flume. Soil samples were collected from the jet test locations and tested in a pressurized flume following standard operational procedure to calculate the critical shear stress. The results were compared using statistical data analysis (mean-separation ANOVA procedure) to identify possible differences. In addition to the device comparison, the mini jet device was used to measure critical shear stress across geologically diverse regions of Tennessee, USA. Statistical correlation between critical shear stress and the soil physical, and geochemical properties were completed identifying that geological origin plays a significant role in critical shear stress prediction for cohesive soils. Finally, the critical shear stress prediction equations using the jet test data were examined with possible suggestions to modify based on the flume test results.
49 CFR 236.557 - Receiver; location with respect to rail.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Rules and Instructions; Locomotives § 236.557 Receiver... automatic cab signal, train stop, or train control device of locomotive equipped with onboard test equipment...
Design and Modeling of a Liquid Lithium LiMIT Loop
NASA Astrophysics Data System (ADS)
Szott, Matthew; Christenson, Michael; Stemmley, Steven; Ahn, Chisung; Andruczyk, Daniel; Ruzic, David
2017-10-01
The use of flowing liquid lithium in plasma facing components has been shown to reduce erosion and thermal stress damage, prolong device lifetime, decrease edge recycling, reduce impurities, and increase plasma performance, all while providing a clean and self-healing surface. The Liquid Metal Infused Trench (LiMIT) system has proven the concept of controlled thermoelectric magnetohydrodynamic-driven lithium flow for use in fusion relevant conditions, through tests at UIUC, HT-7, and Magnum PSI. As the use of liquid lithium in fusion devices progresses, emphasis must now be placed on full systems integration of flowing liquid metal concepts. The LiMIT system will be upgraded to include a full liquid lithium loop, which will pump lithium into the fusion device, utilize TEMHD to drive lithium through the vessel, and remove lithium for filtration and degassing. Flow control concepts recently developed at UIUC - including wetting control, dryout control, and flow velocity control - will be tested in conjunction in order to demonstrate a robust system. Lithium loop system requirements, designs, and modeling work will be presented, along with plans for installation and testing on the HIDRA device at UIUC. This work is supported by DOE/ALPS DE-FG02-99ER54515.
Human performance measuring device
NASA Technical Reports Server (NTRS)
Michael, J.; Scow, J.
1970-01-01
Complex coordinator, consisting of operator control console, recorder, subject display panel, and limb controls, measures human performance by testing perceptual and motor skills. Device measures psychophysiological functions in drug and environmental studies, and is applicable to early detection of psychophysiological body changes.
49 CFR 236.577 - Test, acknowledgement, and cut-in circuits.
Code of Federal Regulations, 2011 CFR
2011-10-01
... INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Inspection and Tests; Roadway § 236.577 Test...
A novel BCI-controlled pneumatic glove system for home-based neurorehabilitation.
Coffey, Aodhán L; Leamy, Darren J; Ward, Tomás E
2014-01-01
Commercially available devices for Brain-Computer Interface (BCI)-controlled robotic stroke rehabilitation are prohibitively expensive for many researchers who are interested in the topic and physicians who would utilize such a device. Additionally, they are cumbersome and require a technician to operate, increasing the inaccessibility of such devices for home-based robotic stroke rehabilitation therapy. Presented here is the design, implementation and test of an inexpensive, portable and adaptable BCI-controlled hand therapy device. The system utilizes a soft, flexible, pneumatic glove which can be used to deflect the subject's wrist and fingers. Operation is provided by a custom-designed pneumatic circuit. Air flow is controlled by an embedded system, which receives serial port instruction from a PC running real-time BCI software. System tests demonstrate that glove control can be successfully driven by a real-time BCI. A system such as the one described here may be used to explore closed loop neurofeedback rehabilitation in stroke relatively inexpensively and potentially in home environments.
49 CFR 236.588 - Periodic test.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.588 Periodic test. Except as provided in § 236.586, periodic test of the automatic train stop, train control, or cab signal apparatus...
A Resonant Pulse Detonation Actuator for High-Speed Boundary Layer Separation Control
NASA Technical Reports Server (NTRS)
Beck, B. T.; Cutler, A. D.; Drummond, J. P.; Jones, S. B.
2004-01-01
A variety of different types of actuators have been previously investigated as flow control devices. Potential applications include the control of boundary layer separation in external flows, as well as jet engine inlet and diffuser flow control. The operating principles for such devices are typically based on either mechanical deflection of control surfaces (which include MEMS flap devices), mass injection (which includes combustion driven jet actuators), or through the use of synthetic jets (diaphragm devices which produce a pulsating jet with no net mass flow). This paper introduces some of the initial flow visualization work related to the development of a relatively new type of combustion-driven jet actuator that has been proposed based on a pulse detonation principle. The device is designed to utilize localized detonation of a premixed fuel (Hydrogen)-air mixture to periodically inject a jet of gas transversely into the primary flow. Initial testing with airflow successfully demonstrated resonant conditions within the range of acoustic frequencies expected for the design. Schlieren visualization of the pulsating air jet structure revealed axially symmetric vortex flow, along with the formation of shocks. Flow visualization of the first successful sustained oscillation condition is also demonstrated for one configuration of the current test section. Future testing will explore in more detail the onset of resonant combustion and the approach to conditions of sustained resonant detonation.
Electronic materials testing in commercial aircraft engines
NASA Astrophysics Data System (ADS)
Brand, Dieter
A device for the electronic testing of materials used in commercial aircraft engines is described. The instrument can be used for ferromagnetic, ferrimagnetic, and nonferromagnetic metallic materials, and it functions either optically or acoustically. The design of the device is described and technical data are given. The device operates under the principle of controlled self-inductivity. Its mode of operation is described.
Code of Federal Regulations, 2011 CFR
2011-07-01
... device emission destruction or removal efficiency? 63.3166 Section 63.3166 Protection of Environment... Limitations § 63.3166 How do I determine the add-on control device emission destruction or removal efficiency... emission destruction or removal efficiency as part of the performance test required by § 63.3160. You must...
Code of Federal Regulations, 2010 CFR
2010-07-01
... device emission destruction or removal efficiency? 63.3166 Section 63.3166 Protection of Environment... Limitations § 63.3166 How do I determine the add-on control device emission destruction or removal efficiency... emission destruction or removal efficiency as part of the performance test required by § 63.3160. You must...
Code of Federal Regulations, 2011 CFR
2011-07-01
... device emission destruction or removal efficiency? 63.4766 Section 63.4766 Protection of Environment... Option § 63.4766 How do I determine the add-on control device emission destruction or removal efficiency... emission destruction or removal efficiency as part of the performance test required by § 63.4760. You must...
40 CFR 63.997 - Performance test and compliance assessment requirements for control devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
...), each run shall represent at least one complete tank truck or tank car loading period, during which... stream is introduced with the combustion air or as a secondary fuel into a boiler or process heater with... specified in paragraph (e)(2)(iii)(C) of this section if a combustion device is the control device and...
DOT National Transportation Integrated Search
2009-05-01
The primary objective of this research was to develop models that predict the resilient modulus of cohesive and granular soils from the test results of various in-situ test devices for possible application in QA/QC during construction of pavement str...
Re-active Passive (RAP) Devices for Control of Noise Transmission through a Panel
NASA Technical Reports Server (NTRS)
Carneal, James P.; Giovanardi, Marco; Fuller, Chris R.; Palumbo, Daniel L.
2008-01-01
Re-Active Passive (RAP) devices have been developed to control low frequency (<1000 Hz) noise transmission through a panel. These devices use a combination of active, re-active, and passive technologies packaged into a single unit to control a broad frequency range utilizing the strength of each technology over its best suited frequency range. The RAP device uses passive constrained layer damping to cover the relatively high frequency range (>200 Hz), reactive distributed vibration absorber) to cover the medium frequency range (75 to 250 Hz), and active control for controlling low frequencies (<200 Hz). The device was applied to control noise transmission through a panel mounted in a transmission loss test facility. Experimental results are presented for the bare panel, and combinations of passive treatment, reactive treatment, and active control. Results indicate that three RAP devices were able to increase the overall broadband (15-1000 Hz) transmission loss by 9.4 dB. These three devices added a total of 285 grams to the panel mass of 6.0 kg, or approximately 5%, not including control electronics.
Thornberg, Steven M; Brown, Jason
2015-02-17
A method of detecting leaks and measuring volumes as well as a device, the Power-free Pump Module (PPM), provides a self-contained leak test and volume measurement apparatus that requires no external sources of electrical power during leak testing or volume measurement. The PPM is a portable, pneumatically-controlled instrument capable of generating a vacuum, calibrating volumes, and performing quantitative leak tests on a closed test system or device, all without the use of alternating current (AC) power. Capabilities include the ability is to provide a modest vacuum (less than 10 Torr) using a venturi pump, perform a pressure rise leak test, measure the gas's absolute pressure, and perform volume measurements. All operations are performed through a simple rotary control valve which controls pneumatically-operated manifold valves.
[Research of joint-robotics-based design of biomechanics testing device on human spine].
Deng, Guoyong; Tian, Lianfang; Mao, Zongyuan
2009-12-01
This paper introduces the hardware and software of a biomechanical robot-based testing device. The bottom control orders, posture and torque data transmission, and the control algorithms are integrated in a unified visual control platform by Visual C+ +, with easy control and management. By using hybrid force-displacement control method to load the human spine, we can test the organizational structure and the force state of the FSU (Functional spinal unit) well, which overcomes the shortcomings due to the separation of the force and displacement measurement, thus greatly improves the measurement accuracy. Also it is esay to identify the spinal degeneration and the load-bearing impact on the organizational structure of the FSU after various types of surgery.
NASA Astrophysics Data System (ADS)
Caldwell, Ryan; Mandal, Himadri; Sharma, Rohit; Solzbacher, Florian; Tathireddy, Prashant; Rieth, Loren
2017-08-01
Objective. Performance of many dielectric coatings for neural electrodes degrades over time, contributing to loss of neural signals and evoked percepts. Studies using planar test substrates have found that a novel bilayer coating of atomic-layer deposited (ALD) Al2O3 and parylene C is a promising candidate for neural electrode applications, exhibiting superior stability to parylene C alone. However, initial results from bilayer encapsulation testing on non-planar devices have been less positive. Our aim was to evaluate ALD Al2O3-parylene C coatings using novel test paradigms, to rigorously evaluate dielectric coatings for neural electrode applications by incorporating neural electrode topography into test structure design. Approach. Five test devices incorporated three distinct topographical features common to neural electrodes, derived from the utah electrode array (UEA). Devices with bilayer (52 nm Al2O3 + 6 µm parylene C) were evaluated against parylene C controls (N ⩾ 6 per device type). Devices were aged in phosphate buffered saline at 67 °C for up to 311 d, and monitored through: (1) leakage current to evaluate encapsulation lifetimes (>1 nA during 5VDC bias indicated failure), and (2) wideband (1-105 Hz) impedance. Main results. Mean-times-to-failure (MTTFs) ranged from 12 to 506 d for bilayer-coated devices, versus 10 to >2310 d for controls. Statistical testing (log-rank test, α = 0.05) of failure rates gave mixed results but favored the control condition. After failure, impedance loss for bilayer devices continued for months and manifested across the entire spectrum, whereas the effect was self-limiting after several days, and restricted to frequencies <100 Hz for controls. These results correlated well with observations of UEAs encapsulated with bilayer and control films. Significance. We observed encapsulation failure modes and behaviors comparable to neural electrode performance which were undetected in studies with planar test devices. We found the impact of parylene C defects to be exacerbated by ALD Al2O3, and conclude that inferior bilayer performance arises from degradation of ALD Al2O3 when directly exposed to saline. This is an important consideration, given that neural electrodes with bilayer coatings are expected to have ALD Al2O3 exposed at dielectric boundaries that delineate electrode sites. Process improvements and use of different inorganic coatings to decrease dissolution in physiological fluids may improve performance. Testing frameworks which take neural electrode complexities into account will be well suited to reliably evaluate such encapsulation schemes.
10 CFR 72.164 - Control of measuring and test equipment.
Code of Federal Regulations, 2010 CFR
2010-01-01
..., instruments, and other measuring and testing devices used in activities affecting quality are properly... WASTE Quality Assurance § 72.164 Control of measuring and test equipment. The licensee, applicant for a... 10 Energy 2 2010-01-01 2010-01-01 false Control of measuring and test equipment. 72.164 Section 72...
Advanced patient transfer assist device with intuitive interaction control.
Humphreys, Heather C; Choi, Young Mi; Book, Wayne J
2017-10-24
This research aims to improve patient transfers by developing a new type of advanced robotic assist device. It has multiple actuated degrees of freedom and a powered steerable base to maximize maneuverability around obstacles. An intuitive interface and control strategy allows the caregiver to simply push on the machine in the direction of desired patient motion. The control integrates measurements of both force and proximity to mitigate any potential large collision forces and provides operators information about obstacles with a form of haptic feedback. Electro-hydraulic pump controlled actuation provides high force density for the actuation. Nineteen participants performed tests to compare transfer operations (transferring a 250-lb mannequin between a wheelchair, chair, bed, and floor) and interaction control of a prototype device with a commercially available patient lift. The testing included a time study of the transfer operations and subjective rating of device performance. The results show that operators perform transfer tasks significantly faster and rate performance higher using the prototype patient transfer assist device than with a current market patient lift. With further development, features of the new patient lift can help facilitate patient transfers that are safer, easier, and more efficient for caregivers.
49 CFR 236.587 - Departure test.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.587 Departure test. (a) The automatic train stop, train control, or cab signal apparatus on each locomotive, except a locomotive or a...
10 CFR 71.125 - Control of measuring and test equipment.
Code of Federal Regulations, 2010 CFR
2010-01-01
... MATERIAL Quality Assurance § 71.125 Control of measuring and test equipment. The licensee, certificate holder, and applicant for a CoC shall establish measures to assure that tools, gauges, instruments, and other measuring and testing devices used in activities affecting quality are properly controlled...
Cooperative system and method using mobile robots for testing a cooperative search controller
Byrne, Raymond H.; Harrington, John J.; Eskridge, Steven E.; Hurtado, John E.
2002-01-01
A test system for testing a controller provides a way to use large numbers of miniature mobile robots to test a cooperative search controller in a test area, where each mobile robot has a sensor, a communication device, a processor, and a memory. A method of using a test system provides a way for testing a cooperative search controller using multiple robots sharing information and communicating over a communication network.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-10
...] Agency Information Collection Activities; Submission for Office of Management and Budget Review; Comment... Antibacterial Drug Products and Antimicrobial Susceptibility Testing Devices AGENCY: Food and Drug... Systemic Antibacterial Drug Products and Antimicrobial Susceptibility Testing Devices--(OMB Control Number...
Wind Tunnel Testing of Microtabs and Microjets for Active Load Control of Wind Turbine Blades
NASA Astrophysics Data System (ADS)
Cooperman, Aubryn Murray
Increases in wind turbine size have made controlling loads on the blades an important consideration for future turbine designs. One approach that could reduce extreme loads and minimize load variation is to incorporate active control devices into the blades that are able to change the aerodynamic forces acting on the turbine. A wind tunnel model has been constructed to allow testing of different active aerodynamic load control devices. Two such devices have been tested in the UC Davis Aeronautical Wind Tunnel: microtabs and microjets. Microtabs are small surfaces oriented perpendicular to an airfoil surface that can be deployed and retracted to alter the lift coefficient of the airfoil. Microjets produce similar effects using air blown perpendicular to the airfoil surface. Results are presented here for both static and dynamic performance of the two devices. Microtabs, located at 95% chord on the lower surface and 90% chord on the upper surface, with a height of 1% chord, produce a change in the lift coefficient of 0.18, increasing lift when deployed on the lower surface and decreasing lift when deployed on the upper surface. Microjets with a momentum coefficient of 0.006 at the same locations produce a change in the lift coefficient of 0.19. The activation time for both devices is less than 0.3 s, which is rapid compared to typical gust rise times. The potential of active device to mitigate changes in loads was tested using simulated gusts. The gusts were produced in the wind tunnel by accelerating the test section air speed at rates of up to 7 ft/s 2. Open-loop control of microtabs was tested in two modes: simultaneous and sequential tab deployment. Activating all tabs along the model span simultaneously was found to produce a change in the loads that occurred more rapidly than a gust. Sequential tab deployment more closely matched the rates of change due to gusts and tab deployment. A closed-loop control system was developed for the microtabs using a simple feedback control based on lift measurements from a six-component balance. An alternative input to the control system that would be easier to implement on a turbine was also investigated: the lift force was estimated using the difference in surface pressure at 15% chord. Both control system approaches were found to decrease lift deviations by around 50% during rapid changes in the free stream air speed.
Krueger, Wesley W.O.
2010-01-01
Objectives/Hypotheses An eyewear mounted visual display (“User-worn see-through display”) projecting an artificial horizon aligned with the user's head and body position in space can prevent or lessen motion sickness in susceptible individuals when in a motion provocative environment as well as aid patients undergoing vestibular rehabilitation. In this project, a wearable display device, including software technology and hardware, was developed and a phase I feasibility study and phase II clinical trial for safety and efficacy were performed. Study Design Both phase I and phase II were prospective studies funded by the NIH. The phase II study used repeated measures for motion intolerant subjects and a randomized control group (display device/no display device) pre-post test design for patients in vestibular rehabilitation. Methods Following technology and display device development, 75 patients were evaluated by test and rating scales in the phase II study; 25 subjects with motion intolerance used the technology in the display device in provocative environments and completed subjective rating scales while 50 patients were evaluated before and after vestibular rehabilitation (25 using the display device and 25 in a control group) using established test measures. Results All patients with motion intolerance rated the technology as helpful for nine symptoms assessed, and 96% rated the display device as simple and easy to use. Duration of symptoms significantly decreased with use of the technology displayed. In patients undergoing vestibular rehabilitation, there were no significant differences in amount of change from pre- to post-therapy on objective balance tests between display device users and controls. However, those using the technology required significantly fewer rehabilitation sessions to achieve those outcomes than the control group. Conclusions A user-worn see-through display, utilizing a visual fixation target coupled with a stable artificial horizon and aligned with user movement, has demonstrated substantial benefit for individuals susceptible to motion intolerance and spatial disorientation and those undergoing vestibular rehabilitation. The technology developed has applications in any environment where motion sensitivity affects human performance. PMID:21181963
Weber-Spickschen, Thomas Sanjay; Colcuc, Christian; Hanke, Alexander; Clausen, Jan-Dierk; James, Paul Abraham; Horstmann, Hauke
2017-01-01
The initial goals of rehabilitation after knee injuries and operations are to achieve full knee extension and to activate quadriceps muscle. In addition to regular physiotherapy, an android-based knee training device is designed to help patients achieve these goals and improve compliance in the early rehabilitation period. This knee training device combines fun in a computer game with muscular training or rehabilitation. Our aim was to test the feasibility and acceptability of this new device. 50 volunteered subjects enrolled to test out the computer game aided device. The first game was the high-striker game, which recorded maximum knee extension power. The second game involved controlling quadriceps muscular power to simulate flying an aeroplane in order to record accuracy of muscle activation. The subjects evaluated this game by completing a simple questionnaire. No technical problem was encountered during the usage of this device. No subjects complained of any discomfort after using this device. Measurements including maximum knee extension power, knee muscle activation and control were recorded successfully. Subjects rated their experience with the device as either excellent or very good and agreed that the device can motivate and monitor the progress of knee rehabilitation training. To the best of our knowledge, this is the first android-based tool available to fast track knee rehabilitation training. All subjects gave very positive feedback to this computer game aided knee device.
Direct surgeon control of the computer in the operating room.
Onceanu, Dumitru; Stewart, A James
2011-01-01
This paper describes the design and evaluation of a joystick-like device that allows direct surgeon control of the computer in the operating room. The device contains no electronic parts, is easy to use, is unobtrusive, has no physical connection to the computer, and makes use of an existing surgical tool. The device was tested in comparison to a mouse and to verbal dictation.
Development of Automated Testing Tools for Traffic Control Signals and Devices : [Summary
DOT National Transportation Integrated Search
2012-01-01
Section 316.0745, Florida : Statutes, requires FDOT to : develop and publish specifi : cations for traffi c control : signals and devices and certify : they meet these specifi : cations before they can be : sold or purchased as part : of a traffi c c...
STS-41 Commander Richards uses DTO 1206 portable computer onboard OV-103
NASA Technical Reports Server (NTRS)
1990-01-01
STS-41 Commander Richard N. Richards, at pilots station, uses Detailed Test Objective (DTO) Space Station Cursor Control Device Evaluation MACINTOSH portable computer on the forward flight deck of Discovery, Orbiter Vehicle (OV) 103. Richards tests the roller ball cursor control device. Surrounding Richards are checklists, forward flight deck windows, his lightweight communications kit assembly headset, a beverage container (orange-mango drink), and the pilots seat back and headrest.
Implantable physiologic controller for left ventricular assist devices with telemetry capability.
Asgari, Siavash S; Bonde, Pramod
2014-01-01
Rotary type left ventricular assist devices have mitigated the problem of durability associated with earlier pulsatile pumps and demonstrated improved survival. However, the compromise is the loss of pulsatility due to continuous flow and retained percutaneous driveline leading to increased mortality and morbidity. Lack of pulsatility is implicated in increased gastrointestinal bleeding, aortic incompetence, and diastolic hypertension. We present a novel, wirelessly powered, ultra-compact, implantable physiologic controller capable of running a left ventricular assist device in a pulsatile mode with wireless power delivery. The schematic of our system was laid out on a circuit board to wirelessly receive power and run a left ventricular assist device with required safety and backup measures. We have embedded an antenna and wireless network for telemetry. Multiple signal processing steps and controlling algorithm were incorporated. The controller was tested in in vitro and in vivo experiments. The controller drove left ventricular assist devices continuously for 2 weeks in an in vitro setup and in vivo without any failure. Our controller is more power efficient than the current Food and Drug Administration-approved left ventricular assist device controllers. When used with electrocardiography synchronization, the controller allowed on-demand customization of operation with instantaneous flow and revolutions per minute changes, resulting in a pulsatile flow with adjustable pulse pressure. Our test results prove the system to be remarkably safe, accurate, and efficient. The unique combination of wireless powering and small footprint makes this system an ideal totally implantable physiologic left ventricular assist device system. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
40 CFR 63.3100 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2010 CFR
2010-07-01
... compliance with the operating limits for emission capture systems and add-on control devices required by § 63... maintain a log detailing the operation and maintenance of the emission capture systems, add-on control... add-on control device performance tests have been completed, as specified in § 63.3160. (f) If your...
40 CFR 63.3100 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2011 CFR
2011-07-01
... compliance with the operating limits for emission capture systems and add-on control devices required by § 63... maintain a log detailing the operation and maintenance of the emission capture systems, add-on control... add-on control device performance tests have been completed, as specified in § 63.3160. (f) If your...
An Investigation of the Performance of Various Reaction Control Devices
NASA Technical Reports Server (NTRS)
Hunter, Paul A.
1959-01-01
An investigation of a small-scale reaction control devices in still air with both subsonic and supersonic internal flows has shown that lateral forces approaching 70 percent of the resultant force of the undeflected jet can be obtained. These results were obtained with a tilted extension at a deflection of 40 deg. The tests of tilted extensions indicated an optimum length-to-diameter ratio of approximately 0.75 to 1.00, dependent upon the deflection angle. For the two geometric types of spoiler tabs tested, blockage-area ratio appears to be the only variable affecting the lateral force developed. Usable values of lateral force were developed by the full-eyelid type of device with reasonably small losses in the thrust and weight flow. Somewhat larger values of lateral force were developed by injecting a secondary flow normal to the primary jet, but for conditions of these tests the losses in thrust and weight flow were large. Relatively good agreement with other investigations was obtained for several of the devices. The agreement of the present results with those of an investigation made with larger-scale equipment indicates that Reynolds number may not be critical for these tests. In as much as the effects of external flow could influence the performance and other factors affecting the choice of a reaction control for a specific use, it would appear desirable to make further tests of the devices described in this report in the presence of external flow.
Krueger, Wesley W O
2011-01-01
An eyewear mounted visual display ("User-worn see-through display") projecting an artificial horizon aligned with the user's head and body position in space can prevent or lessen motion sickness in susceptible individuals when in a motion provocative environment as well as aid patients undergoing vestibular rehabilitation. In this project, a wearable display device, including software technology and hardware, was developed and a phase I feasibility study and phase II clinical trial for safety and efficacy were performed. Both phase I and phase II were prospective studies funded by the NIH. The phase II study used repeated measures for motion intolerant subjects and a randomized control group (display device/no display device) pre-posttest design for patients in vestibular rehabilitation. Following technology and display device development, 75 patients were evaluated by test and rating scales in the phase II study; 25 subjects with motion intolerance used the technology in the display device in provocative environments and completed subjective rating scales, whereas 50 patients were evaluated before and after vestibular rehabilitation (25 using the display device and 25 in a control group) using established test measures. All patients with motion intolerance rated the technology as helpful for nine symptoms assessed, and 96% rated the display device as simple and easy to use. Duration of symptoms significantly decreased with use of the technology displayed. In patients undergoing vestibular rehabilitation, there were no significant differences in amount of change from pre- to posttherapy on objective balance tests between display device users and controls. However, those using the technology required significantly fewer rehabilitation sessions to achieve those outcomes than the control group. A user-worn see-through display, utilizing a visual fixation target coupled with a stable artificial horizon and aligned with user movement, has demonstrated substantial benefit for individuals susceptible to motion intolerance and spatial disorientation and those undergoing vestibular rehabilitation. The technology developed has applications in any environment where motion sensitivity affects human performance.
21 CFR 862.1505 - Mucopolysaccharides (nonquantitative) test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry..., Scheie's Morquio's and Maroteaux-Lamy syndromes. (b) Classification. Class I (general controls). The...
21 CFR 866.5360 - Cohn fraction IV immuno-logical test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
...-lipoprotein), malnutrition, iron deficiency anemia, red blood cell disorders, and kidney disease. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in... test system is a device that consists of or measures that fraction of plasma proteins, predominantly...
21 CFR 866.5360 - Cohn fraction IV immuno-logical test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
...-lipoprotein), malnutrition, iron deficiency anemia, red blood cell disorders, and kidney disease. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in... test system is a device that consists of or measures that fraction of plasma proteins, predominantly...
21 CFR 866.5360 - Cohn fraction IV immuno-logical test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
...-lipoprotein), malnutrition, iron deficiency anemia, red blood cell disorders, and kidney disease. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in... test system is a device that consists of or measures that fraction of plasma proteins, predominantly...
21 CFR 866.5360 - Cohn fraction IV immuno-logical test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
...-lipoprotein), malnutrition, iron deficiency anemia, red blood cell disorders, and kidney disease. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in... test system is a device that consists of or measures that fraction of plasma proteins, predominantly...
A magnetic bearing control approach using flux feedback
NASA Technical Reports Server (NTRS)
Groom, Nelson J.
1989-01-01
A magnetic bearing control approach using flux feedback is described and test results for a laboratory model magnetic bearing actuator are presented. Test results were obtained using a magnetic bearing test fixture, which is also described. The magnetic bearing actuator consists of elements similar to those used in a laboratory test model Annular Momentum Control Device (AMCD).
Code of Federal Regulations, 2011 CFR
2011-07-01
... system and add-on control device operating limits during the performance test? 63.4966 Section 63.4966... outlet gas temperature is the maximum operating limit for your condenser. (e) Emission capture system... with Add-on Controls Option § 63.4966 How do I establish the emission capture system and add-on control...
Code of Federal Regulations, 2010 CFR
2010-07-01
... system and add-on control device operating limits during the performance test? 63.4966 Section 63.4966... outlet gas temperature is the maximum operating limit for your condenser. (e) Emission capture system... with Add-on Controls Option § 63.4966 How do I establish the emission capture system and add-on control...
Wade, Matthew; Isom, Ryan; Georgescu, Dan; Olson, Randall J
2007-06-01
To determine the efficacy of the Cruise Control surge-limiting device (Staar Surgical) with phacoemulsification machines known to have high levels of surge. John A. Moran Eye Center Clinical Laboratories. In an in vitro study, postocclusion anterior chamber depth changes were measured in fresh phakic human eye-bank eyes using the Alcon Legacy and Bausch & Lomb Millennium venturi machines in conjunction with the Staar Cruise Control device. Both machines were tested with 19-gauge non-Aspiration Bypass System tips at high-surge settings (500 mm Hg vacuum pressure, 75 cm bottle height, 40 mL/min flow rate for the Legacy) and low-surge settings (400 mm Hg vacuum pressure, 125 cm bottle height, 40 mL/min flow rate for the Legacy). Adjusted parameters of flow, vacuum, and irrigation were used based on previous studies to create identical conditions for each device tested. The effect of the Cruise Control device on aspiration rates was also tested with both machines at the low-surge settings. At the high setting with the addition of Cruise Control, surge decreased significantly with the Legacy but was too large to measure with the Millennium venturi. At the low setting with the addition of Cruise Control, surge decreased significantly with both machines. Surge with the Millennium decreased from more than 1.0 mm to a mean of 0.21 mm +/- 0.02 (SD) (P<.0001). Surge with the Legacy decreased from a mean of 0.09 +/- 0.02 mm to 0.05 +/- 0 mm, a 42.9% decrease (P<.0001). The Millennium had the highest surge and aspiration rate before Cruise Control and the greatest percentage decrease in the surge and aspiration rates as a result of the addition of Cruise Control. In the Legacy machine, the Cruise Control device had a statistically and clinically significant effect. Cruise Control had a large effect on fluidics as well as surge amplitude with the Millennium machine. The greater the flow or greater the initial surge, the greater the impact of the Cruise Control device.
40 CFR 63.9020 - What performance tests and other procedures must I use?
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Hydrochloric Acid Production...) If you use a caustic scrubber control device or a water scrubber control device, the design...
Re-Active Passive devices for control of noise transmission through a panel
NASA Astrophysics Data System (ADS)
Carneal, James P.; Giovanardi, Marco; Fuller, Chris R.; Palumbo, Dan
2008-01-01
Re-Active Passive devices have been developed to control low-frequency (<1000 Hz) noise transmission through a panel. These devices use a combination of active, re-active, and passive technologies packaged into a single unit to control a broad frequency range utilizing the strength of each technology over its best suited frequency range. The Re-Active Passive device uses passive constrained layer damping to cover relatively high-frequency range (>150 Hz), reactive distributed vibration absorber to cover the medium-frequency range (50-200 Hz), and active control for controlling low frequencies (<150 Hz). The actuator was applied to control noise transmission through a panel mounted in the Transmission Loss Test Facility at Virginia Tech. Experimental results are presented for the bare panel, and combinations of passive treatment, reactive treatment, and active control. Results indicate that three Re-Active Passive devices were able to increase the overall broadband (15-1000 Hz) transmission loss by 9.4 dB. These three devices added a total of 285 g to the panel mass of 6.0 kg, or approximately 5%, not including control electronics.
NASA Technical Reports Server (NTRS)
Weick, Fred E; Noyes, Richard W
1933-01-01
Results are given of a series of systemic tests comparing lateral control devices with particular reference to their effectiveness at high angles of attack. These tests were made with two sizes of ordinary ailerons and different sizes of spoilers on a Clark Y wing model having a narrow auxiliary airfoil fixed ahead and above the leading edge, the chords of the main and auxiliary airfoils being parallel. In addition, the auxiliary airfoil itself was given angular deflection. The purpose was to provide rolling moments for lateral control. The tests were made in a 7 by 10 foot wind tunnel. They included both force and rotation tests to show the effect of the devices on the lift and drag characteristics of the wing and on the lateral stability characteristics, as well as lateral control. They showed that none of the aileron arrangements tried would give rolling control of an assumed satisfactory value at all angles of attack up to the stall. However, they would give satisfactory values, but at the expense of abnormally high deflections and very heavy hinge moments. The most effective combination of ailerons and spoilers gave satisfactory values of rolling moment at angles of attack below the stall, and the values did not fall off as rapidly above the stall as with ailerons alone. With an arrangement of this type having the proper relative proportions and linkage, it should be possible to obtain reasonably satisfactory yawing moments and control forces. Deflecting one-half of the auxiliary airfoil downward for the purpose of control gave strong favorable yawing moments at all angles of attack, but gave very small rolling moments at the low angles of attack.
DoD Comprehensive Military Unmanned Aerial Vehicle Smart Device Ground Control Station Threat Model
2015-04-01
design , imple- mentation, and test evaluation were interviewed to evaluate the existing gaps in the DoD processes for cybersecurity. This group exposed...such as antenna design and signal reception have made satellite communication networks a viable solution for smart devices on the battlefield...DoD Comprehensive Military Unmanned AERIAL VEHICLE SMART DEVICE GROUND CONTROL STATION THREAT MODEL Image designed by Diane Fleischer Report
AN EVALUATION OF STORM DRAINAGE INLET DEVICES FOR STORMWATER QUALITY TREATMENT
The activities summarized in this paper included the testing of three representative stormwater control devices that were located at storm drainage inlets. The two proprietary devices utilized screening and filtering (using filter fabric and a coarser mesh). A conventional catchb...
40 CFR 63.563 - Compliance and performance testing.
Code of Federal Regulations, 2012 CFR
2012-07-01
... source shall perform an unscheduled inspection of the control device and monitoring equipment and review... inspection and review when total parameter variance time for the control device is greater than 10 percent of... inspection and review shall be conducted within 24 hours after passing the allowable variance time of 10...
DOT National Transportation Integrated Search
2013-03-01
Work zone traffic control devices such as temporary single sign supports are a primary means to communicate : information to motorists in work zone areas. The Federal Highway Administration and the Manual on Uniform Traffic : Control Devices require ...
An automated miniaturized Haploscope for testing binocular visual function
NASA Technical Reports Server (NTRS)
Decker, T. A.; Williams, R. E.; Kuether, C. L.; Wyman-Cornsweet, D.
1976-01-01
A computer-controlled binocular vision testing device has been developed as one part of a system designed for NASA to test the vision of astronauts during spaceflight. The device, called the Mark III Haploscope, utilizes semi-automated psychophysical test procedures to measure visual acuity, stereopsis, phorias, fixation disparity and accommodation/convergence relationships. All tests are self-administered, yield quantitative data and may be used repeatedly without subject memorization. Future applications of this programmable, compact device include its use as a clinical instrument to perform routine eye examinations or vision screening, and as a research tool to examine the effects of environment or work-cycle upon visual function.
Effects of Device on Video Head Impulse Test (vHIT) Gain.
Janky, Kristen L; Patterson, Jessie N; Shepard, Neil T; Thomas, Megan L A; Honaker, Julie A
2017-10-01
Numerous video head impulse test (vHIT) devices are available commercially; however, gain is not calculated uniformly. An evaluation of these devices/algorithms in healthy controls and patients with vestibular loss is necessary for comparing and synthesizing work that utilizes different devices and gain calculations. Using three commercially available vHIT devices/algorithms, the purpose of the present study was to compare: (1) horizontal canal vHIT gain among devices/algorithms in normal control subjects; (2) the effects of age on vHIT gain for each device/algorithm in normal control subjects; and (3) the clinical performance of horizontal canal vHIT gain between devices/algorithms for differentiating normal versus abnormal vestibular function. Prospective. Sixty-one normal control adult subjects (range 20-78) and eleven adults with unilateral or bilateral vestibular loss (range 32-79). vHIT was administered using three different devices/algorithms, randomized in order, for each subject on the same day: (1) Impulse (Otometrics, Schaumberg, IL; monocular eye recording, right eye only; using area under the curve gain), (2) EyeSeeCam (Interacoustics, Denmark; monocular eye recording, left eye only; using instantaneous gain), and (3) VisualEyes (MicroMedical, Chatham, IL, binocular eye recording; using position gain). There was a significant mean difference in vHIT gain among devices/algorithms for both the normal control and vestibular loss groups. vHIT gain was significantly larger in the ipsilateral direction of the eye used to measure gain; however, in spite of the significant mean differences in vHIT gain among devices/algorithms and the significant directional bias, classification of "normal" versus "abnormal" gain is consistent across all compared devices/algorithms, with the exception of instantaneous gain at 40 msec. There was not an effect of age on vHIT gain up to 78 years regardless of the device/algorithm. These findings support that vHIT gain is significantly different between devices/algorithms, suggesting that care should be taken when making direct comparisons of absolute gain values between devices/algorithms. American Academy of Audiology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, F.W.; Back, G.G.; Burns, R.E.
1986-11-04
Constant flow devices, which deliver a constant flow of liquid over a range of upstream and downstream pressures, have been suggested as an alternative to orifice plates for proportioning AFFF in SSN 21 fire-suppression systems. Operational and performance characteristics of two lightweight, inexpensive, commercially available constant-flow devices have significant advantages over orifice plates. Both models tested, however, showed performance degradation when subjected to simulated service conditions. A constant flow device with improved resistance to wear and to AFFF exposure is desirable. Since the constant-flow control devices tested improves proportioning efficiency but do not have optimum characteristics, investigation of improved devicesmore » or methods is recommended.« less
Code of Federal Regulations, 2010 CFR
2010-07-01
... system and add-on control device operating limits during the performance test? 63.3556 Section 63.3556... of key parameters of the valve operating system (e.g., solenoid valve operation, air pressure.../outlet Concentration Option § 63.3556 How do I establish the emission capture system and add-on control...
Code of Federal Regulations, 2011 CFR
2011-07-01
... system and add-on control device operating limits during the performance test? 63.3556 Section 63.3556... of key parameters of the valve operating system (e.g., solenoid valve operation, air pressure.../outlet Concentration Option § 63.3556 How do I establish the emission capture system and add-on control...
Code of Federal Regulations, 2013 CFR
2013-07-01
... system and add-on control device operating limits during the performance test? 63.3556 Section 63.3556... of key parameters of the valve operating system (e.g., solenoid valve operation, air pressure... Control Efficiency/outlet Concentration Option § 63.3556 How do I establish the emission capture system...
Code of Federal Regulations, 2012 CFR
2012-07-01
... rate, type of control devices, process parameters (e.g., maximum heat input), and non-process... control systems (if applicable) and explain why the conditions are worst-case. (c) Number of test runs... located at the outlet of the control device and prior to any releases to the atmosphere. (e) Collection of...
Code of Federal Regulations, 2011 CFR
2011-07-01
... rate, type of control devices, process parameters (e.g., maximum heat input), and non-process... control systems (if applicable) and explain why the conditions are worst-case. (c) Number of test runs... located at the outlet of the control device and prior to any releases to the atmosphere. (e) Collection of...
Code of Federal Regulations, 2010 CFR
2010-07-01
... rate, type of control devices, process parameters (e.g., maximum heat input), and non-process... control systems (if applicable) and explain why the conditions are worst-case. (c) Number of test runs... located at the outlet of the control device and prior to any releases to the atmosphere. (e) Collection of...
40 CFR 1042.235 - Emission testing related to certification.
Code of Federal Regulations, 2014 CFR
2014-07-01
.... The engine you provide must include appropriate manifolds, aftertreatment devices, electronic control...) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW AND IN-USE MARINE COMPRESSION-IGNITION ENGINES AND VESSELS Certifying Engine Families § 1042.235 Emission testing related to certification. This...
40 CFR 1042.235 - Emission testing related to certification.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... The engine you provide must include appropriate manifolds, aftertreatment devices, electronic control...) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW AND IN-USE MARINE COMPRESSION-IGNITION ENGINES AND VESSELS Certifying Engine Families § 1042.235 Emission testing related to certification. This...
40 CFR 1042.235 - Emission testing related to certification.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... The engine you provide must include appropriate manifolds, aftertreatment devices, electronic control...) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW AND IN-USE MARINE COMPRESSION-IGNITION ENGINES AND VESSELS Certifying Engine Families § 1042.235 Emission testing related to certification. This...
40 CFR 1042.235 - Emission testing related to certification.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... The engine you provide must include appropriate manifolds, aftertreatment devices, electronic control...) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW AND IN-USE MARINE COMPRESSION-IGNITION ENGINES AND VESSELS Certifying Engine Families § 1042.235 Emission testing related to certification. This...
40 CFR 1042.235 - Emission testing related to certification.
Code of Federal Regulations, 2011 CFR
2011-07-01
.... The engine you provide must include appropriate manifolds, aftertreatment devices, electronic control...) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW AND IN-USE MARINE COMPRESSION-IGNITION ENGINES AND VESSELS Certifying Engine Families § 1042.235 Emission testing related to certification. This...
A portable hardware-in-the-loop (HIL) device for automotive diagnostic control systems.
Palladino, A; Fiengo, G; Lanzo, D
2012-01-01
In-vehicle driving tests for evaluating the performance and diagnostic functionalities of engine control systems are often time consuming, expensive, and not reproducible. Using a hardware-in-the-loop (HIL) simulation approach, new control strategies and diagnostic functions on a controller area network (CAN) line can be easily tested in real time, in order to reduce the effort and the cost of the testing phase. Nowadays, spark ignition engines are controlled by an electronic control unit (ECU) with a large number of embedded sensors and actuators. In order to meet the rising demand of lower emissions and fuel consumption, an increasing number of control functions are added into such a unit. This work aims at presenting a portable electronic environment system, suited for HIL simulations, in order to test the engine control software and the diagnostic functionality on a CAN line, respectively, through non-regression and diagnostic tests. The performances of the proposed electronic device, called a micro hardware-in-the-loop system, are presented through the testing of the engine management system software of a 1.6 l Fiat gasoline engine with variable valve actuation for the ECU development version. Copyright © 2011 ISA. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geller, Drew Adam; Backhaus, Scott N.
Control of consumer electrical devices for providing electrical grid services is expanding in both the scope and the diversity of loads that are engaged in control, but there are few experimentally-based models of these devices suitable for control designs and for assessing the cost of control. A laboratory-scale test system is developed to experimentally evaluate the use of a simple window-mount air conditioner for electrical grid regulation services. The experimental test bed is a single, isolated air conditioner embedded in a test system that both emulates the thermodynamics of an air conditioned room and also isolates the air conditioner frommore » the real-world external environmental and human variables that perturb the careful measurements required to capture a model that fully characterizes both the control response functions and the cost of control. The control response functions and cost of control are measured using harmonic perturbation of the temperature set point and a test protocol that further isolates the air conditioner from low frequency environmental variability.« less
NASA Technical Reports Server (NTRS)
Weick, Fred E; Wenzinger, Carl J
1935-01-01
This report covers the twelfth of a series of tests conducted to compare different lateral control devices with particular reference to their effectiveness at high angles of attack. The present wind tunnel tests were made with two sizes of upper-surface ailerons on rectangular Clark Y wing models equipped with full span split flaps. The tests showed the effect of the upper-surface ailerons and of the split flaps on the general performance characteristics of the wings, and on the lateral controllability and stability characteristics. The results are compared with those for plain wings with ordinary ailerons of similar sizes.
Weber-Spickschen, Thomas Sanjay; Colcuc, Christian; Hanke, Alexander; Clausen, Jan-Dierk; James, Paul Abraham; Horstmann, Hauke
2017-01-01
Purpose: The initial goals of rehabilitation after knee injuries and operations are to achieve full knee extension and to activate quadriceps muscle. In addition to regular physiotherapy, an android-based knee training device is designed to help patients achieve these goals and improve compliance in the early rehabilitation period. This knee training device combines fun in a computer game with muscular training or rehabilitation. Our aim was to test the feasibility and acceptability of this new device. Methods: 50 volunteered subjects enrolled to test out the computer game aided device. The first game was the high-striker game, which recorded maximum knee extension power. The second game involved controlling quadriceps muscular power to simulate flying an aeroplane in order to record accuracy of muscle activation. The subjects evaluated this game by completing a simple questionnaire. Results: No technical problem was encountered during the usage of this device. No subjects complained of any discomfort after using this device. Measurements including maximum knee extension power, knee muscle activation and control were recorded successfully. Subjects rated their experience with the device as either excellent or very good and agreed that the device can motivate and monitor the progress of knee rehabilitation training. Conclusion: To the best of our knowledge, this is the first android-based tool available to fast track knee rehabilitation training. All subjects gave very positive feedback to this computer game aided knee device. PMID:29081870
Hydrogen sensors based on catalytic metals
NASA Astrophysics Data System (ADS)
Beklemyshev, V. I.; Berezine, V.; Bykov, Victor A.; Kiselev, L.; Makhonin, I.; Pevgov, V.; Pustovoy, V.; Semynov, A.; Sencov, Y.; Shkuropat, I.; Shokin, A.
1999-11-01
On the base of microelectronical and micromechanical technology were designed and developed converters of hydrogen concentration to electrical signals. The devices of controlling concentration of hydrogen in the air were developed. These devices were applied for ensuring fire and explosion security of complex technological teste of missile oxygen-hydrogen engine, developed for cryogenic accelerations block. The sensor block of such device was installed directly on the armor-plate, to which was attached tested engine.
Control of Combustion-Instabilities Through Various Passive Devices
NASA Technical Reports Server (NTRS)
Frendi, Abdelkader; Nesman, Tom; Canabal, Francisco
2005-01-01
Results of a computational study on the effectiveness of various passive devices for the control of combustion instabilities are presented. An axi-symmetric combustion chamber is considered. The passive control devices investigated are, baffles, Helmholtz resonators and quarter-waves. The results show that a Helmholtz resonator with a smooth orifice achieves the best control results, while a baffle is the least effective for the frequency tested. At high sound pressure levels, the Helmholtz resonator is less effective. It is also found that for a quarter wave, the smoothness of the orifice has the opposite effect than the Helmholtz resonator, i.e. results in less control.
Experimental and simulated control of lift using trailing edge devices
NASA Astrophysics Data System (ADS)
Cooperman, A.; Blaylock, M.; van Dam, C. P.
2014-12-01
Two active aerodynamic load control (AALC) devices coupled with a control algorithm are shown to decrease the change in lift force experienced by an airfoil during a change in freestream velocity. Microtabs are small (1% chord) surfaces deployed perpendicular to an airfoil, while microjets are pneumatic jets with flow perpendicular to the surface of the airfoil near the trailing edge. Both devices are capable of producing a rapid change in an airfoil's lift coefficient. A control algorithm for microtabs has been tested in a wind tunnel using a modified S819 airfoil, and a microjet control algorithm has been simulated for a NACA 0012 airfoil using OVERFLOW. In both cases, the AALC devices have shown the ability to mitigate the changes in lift during a gust.
Control Room at the NACA’s Rocket Engine Test Facility
1957-05-21
Test engineers monitor an engine firing from the control room of the Rocket Engine Test Facility at the National Advisory Committee for Aeronautics (NACA) Lewis Flight Propulsion Laboratory. The Rocket Engine Test Facility, built in the early 1950s, had a rocket stand designed to evaluate high-energy propellants and rocket engine designs. The facility was used to study numerous different types of rocket engines including the Pratt and Whitney RL-10 engine for the Centaur rocket and Rocketdyne’s F-1 and J-2 engines for the Saturn rockets. The Rocket Engine Test Facility was built in a ravine at the far end of the laboratory because of its use of the dangerous propellants such as liquid hydrogen and liquid fluorine. The control room was located in a building 1,600 feet north of the test stand to protect the engineers running the tests. The main control and instrument consoles were centrally located in the control room and surrounded by boards controlling and monitoring the major valves, pumps, motors, and actuators. A camera system at the test stand allowed the operators to view the tests, but the researchers were reliant on data recording equipment, sensors, and other devices to provide test data. The facility’s control room was upgraded several times over the years. Programmable logic controllers replaced the electro-mechanical control devices. The new controllers were programed to operate the valves and actuators controlling the fuel, oxidant, and ignition sequence according to a predetermined time schedule.
Wearable wireless User Interface Cursor-Controller (UIC-C).
Marjanovic, Nicholas; Kerr, Kevin; Aranda, Ricardo; Hickey, Richard; Esmailbeigi, Hananeh
2017-07-01
Controlling a computer or a smartphone's cursor allows the user to access a world full of information. For millions of people with limited upper extremities motor function, controlling the cursor becomes profoundly difficult. Our team has developed the User Interface Cursor-Controller (UIC-C) to assist the impaired individuals in regaining control over the cursor. The UIC-C is a hands-free device that utilizes the tongue muscle to control the cursor movements. The entire device is housed inside a subject specific retainer. The user maneuvers the cursor by manipulating a joystick imbedded inside the retainer via their tongue. The joystick movement commands are sent to an electronic device via a Bluetooth connection. The device is readily recognizable as a cursor controller by any Bluetooth enabled electronic device. The device testing results have shown that the time it takes the user to control the cursor accurately via the UIC-C is about three times longer than a standard computer mouse controlled via the hand. The device does not require any permanent modifications to the body; therefore, it could be used during the period of acute rehabilitation of the hands. With the development of modern smart homes, and enhancement electronics controlled by the computer, UIC-C could be integrated into a system that enables individuals with permanent impairment, the ability to control the cursor. In conclusion, the UIC-C device is designed with the goal of allowing the user to accurately control a cursor during the periods of either acute or permanent upper extremities impairment.
Development of a prototype two-phase thermal bus system for Space Station
NASA Technical Reports Server (NTRS)
Myron, D. L.; Parish, R. C.
1987-01-01
This paper describes the basic elements of a pumped two-phase ammonia thermal control system designed for microgravity environments, the development of the concept into a Space Station flight design, and design details of the prototype to be ground-tested in the Johnson Space Center (JSC) Thermal Test Bed. The basic system concept is one of forced-flow heat transport through interface heat exchangers with anhydrous ammonia being pumped by a device expressly designed for two-phase fluid management in reduced gravity. Control of saturation conditions, and thus system interface temperatures, is accomplished with a single central pressure regulating valve. Flow control and liquid inventory are controlled by passive, nonelectromechanical devices. Use of these simple control elements results in minimal computer controls and high system reliability. Building on the basic system concept, a brief overview of a potential Space Station flight design is given. Primary verification of the system concept will involve testing at JSC of a 25-kW ground test article currently in fabrication.
Development of a novel SCADA system for laboratory testing.
Patel, M; Cole, G R; Pryor, T L; Wilmot, N A
2004-07-01
This document summarizes the supervisory control and data acquisition (SCADA) system that allows communication with, and controlling the output of, various I/O devices in the renewable energy systems and components test facility RESLab. This SCADA system differs from traditional SCADA systems in that it supports a continuously changing operating environment depending on the test to be performed. The SCADA System is based on the concept of having one Master I/O Server and multiple client computer systems. This paper describes the main features and advantages of this dynamic SCADA system, the connections of various field devices to the master I/O server, the device servers, and numerous software features used in the system. The system is based on the graphical programming language "LabVIEW" and its "Datalogging and Supervisory Control" (DSC) module. The DSC module supports a real-time database called the "tag engine," which performs the I/O operations with all field devices attached to the master I/O server and communications with the other tag engines running on the client computers connected via a local area network. Generic and detailed communication block diagrams illustrating the hierarchical structure of this SCADA system are presented. The flow diagram outlining a complete test performed using this system in one of its standard configurations is described.
Discuss the testing problems of ultraviolet irradiance meters
NASA Astrophysics Data System (ADS)
Ye, Jun'an; Lin, Fangsheng
2014-09-01
Ultraviolet irradiance meters are widely used in many areas such as medical treatment, epidemic prevention, energy conservation and environment protection, computers, manufacture, electronics, ageing of material and photo-electric effect, for testing ultraviolet irradiance intensity. So the accuracy of value directly affects the sterile control in hospital, treatment, the prevention level of CDC and the control accuracy of curing and aging in manufacturing industry etc. Because the display of ultraviolet irradiance meters is easy to change, in order to ensure the accuracy, it needs to be recalibrated after being used period of time. By the comparison with the standard ultraviolet irradiance meters, which are traceable to national benchmarks, we can acquire the correction factor to ensure that the instruments working under accurate status and giving the accurate measured data. This leads to an important question: what kind of testing device is more accurate and reliable? This article introduces the testing method and problems of the current testing device for ultraviolet irradiance meters. In order to solve these problems, we have developed a new three-dimensional automatic testing device. We introduce structure and working principle of this system and compare the advantages and disadvantages of two devices. In addition, we analyses the errors in the testing of ultraviolet irradiance meters.
A compact inflow control device for simulating flight fan noise
NASA Technical Reports Server (NTRS)
Homyak, L.; Mcardle, J. G.; Heidelberg, L. J.
1983-01-01
Inflow control device (ICD's) of various shapes and sizes have been used to simulate inflight fan tone noise during ground static tests. A small, simple inexpensive ICD design was optimized from previous design and fabrication techniques. This compact two-fan-diameter ICD exhibits satisfactory acoustic performance characteristics without causing noise attenuation or redirection. In addition, it generates no important new noise sources. Design and construction details of the compact ICD are discussed and acoustic performance test results are presented.
Initial High-Power-CW-Laser Testing of Liquid-Crystal Optical Phased Arrays
2010-02-01
During testing, the pump was operated in its "turbo" mode. The temperature was monitored by one of two devices: an Omega HH82 digital...could be investigated. The bar was controlled by an Omega CN76000 temperature controller. The temperature was monitored by the same two devices used...increased. The traces in figure 6 show the phase modulation come back to life as the power was then lowered to 20 watts, 10 watts, and after
NASA Astrophysics Data System (ADS)
Chan, Wilfred K.; Clingman, Dan J.; Amitay, Michael
2016-04-01
Piezoelectric materials have long been used for active flow control purposes in aerospace applications to increase the effectiveness of aerodynamic surfaces on aircraft, wind turbines, and more. Piezoelectric actuators are an appropriate choice due to their low mass, small dimensions, simplistic design, and frequency response. This investigation involves the development of piezoceramic-based actuators with two bimorphs placed in series. Here, the main desired characteristic was the achievable displacement amplitude at specific driving voltages and frequencies. A parametric study was performed, in which actuators with varying dimensions were fabricated and tested. These devices were actuated with a sinusoidal waveform, resulting in an oscillating platform on which to mount active flow control devices, such as dynamic vortex generators. The main quantification method consisted of driving these devices with different voltages and frequencies to determine their free displacement, blocking force, and frequency response. It was found that resonance frequency increased with shorter and thicker actuators, while free displacement increased with longer and thinner actuators. Integration of the devices into active flow control test modules is noted. In addition to physical testing, a quasi-static analytical model was developed and compared with experimental data, which showed close correlation for both free displacement and blocking force.
21 CFR 862.1255 - 2,3-Diphosphoglyceric acid test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... acid test system is a device intended to measure 2,3-diphosphoglyceric acid (2,3-DPG) in erythrocytes (red blood cells). Measurements of 2,3-diphosphoglyceric acid are used in the diagnosis and treatment... the quality of stored blood. (b) Classification. Class I (general controls). The device is exempt from...
21 CFR 876.5870 - Sorbent hemoperfusion system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... extracorporeal blood system. The device is used in the treatment of poisoning, drug overdose, hepatic coma, or... the treatment of poisoning and drug overdose. The special controls for this device are: (i) The device... electrical components, appropriate analysis and testing must be conducted to verify electrical safety and...
40 CFR 65.158 - Performance test procedures for control devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... regulated material or as TOC (minus methane and ethane) according to the procedures specified. (1) Method 1... material or TOC, sampling sites shall be located at the inlet of the control device as specified in the... sampling sites shall ensure the measurement of total regulated material or TOC (minus methane and ethane...
40 CFR 63.6620 - What performance tests and other procedures must I use?
Code of Federal Regulations, 2014 CFR
2014-07-01
... Where: Ci = concentration of carbon monoxide (CO), total hydrocarbons (THC), or formaldehyde at the control device inlet, Co = concentration of CO, THC, or formaldehyde at the control device outlet, and R = percent reduction of CO, THC, or formaldehyde emissions. (2) You must normalize the CO, THC, or...
40 CFR 63.6620 - What performance tests and other procedures must I use?
Code of Federal Regulations, 2013 CFR
2013-07-01
... Where: Ci = concentration of carbon monoxide (CO), total hydrocarbons (THC), or formaldehyde at the control device inlet, Co = concentration of CO, THC, or formaldehyde at the control device outlet, and R = percent reduction of CO, THC, or formaldehyde emissions. (2) You must normalize the CO, THC, or...
40 CFR 63.3000 - What notifications and reports must I submit?
Code of Federal Regulations, 2010 CFR
2010-07-01
... reporting period. (v) The date of the latest continuous parameter monitoring system certification or audit... parameter monitoring system, or add-on control device since the last semiannual reporting period. (4) No...-on control devices no later than 60 days after completing the tests as specified in § 63.10(d)(2...
Masalski, Marcin; Kipiński, Lech; Grysiński, Tomasz; Kręcicki, Tomasz
2016-05-30
Hearing tests carried out in home setting by means of mobile devices require previous calibration of the reference sound level. Mobile devices with bundled headphones create a possibility of applying the predefined level for a particular model as an alternative to calibrating each device separately. The objective of this study was to determine the reference sound level for sets composed of a mobile device and bundled headphones. Reference sound levels for Android-based mobile devices were determined using an open access mobile phone app by means of biological calibration, that is, in relation to the normal-hearing threshold. The examinations were conducted in 2 groups: an uncontrolled and a controlled one. In the uncontrolled group, the fully automated self-measurements were carried out in home conditions by 18- to 35-year-old subjects, without prior hearing problems, recruited online. Calibration was conducted as a preliminary step in preparation for further examination. In the controlled group, audiologist-assisted examinations were performed in a sound booth, on normal-hearing subjects verified through pure-tone audiometry, recruited offline from among the workers and patients of the clinic. In both the groups, the reference sound levels were determined on a subject's mobile device using the Bekesy audiometry. The reference sound levels were compared between the groups. Intramodel and intermodel analyses were carried out as well. In the uncontrolled group, 8988 calibrations were conducted on 8620 different devices representing 2040 models. In the controlled group, 158 calibrations (test and retest) were conducted on 79 devices representing 50 models. Result analysis was performed for 10 most frequently used models in both the groups. The difference in reference sound levels between uncontrolled and controlled groups was 1.50 dB (SD 4.42). The mean SD of the reference sound level determined for devices within the same model was 4.03 dB (95% CI 3.93-4.11). Statistically significant differences were found across models. Reference sound levels determined in the uncontrolled group are comparable to the values obtained in the controlled group. This validates the use of biological calibration in the uncontrolled group for determining the predefined reference sound level for new devices. Moreover, due to a relatively small deviation of the reference sound level for devices of the same model, it is feasible to conduct hearing screening on devices calibrated with the predefined reference sound level.
Code of Federal Regulations, 2013 CFR
2013-07-01
... system and add-on control device operating limits during the performance test? 63.4966 Section 63.4966... outlet gas temperature is the maximum operating limit for your condenser. (e) Emission capture system... Emission Rate with Add-on Controls Option § 63.4966 How do I establish the emission capture system and add...
Wells, Sue; Rafter, Natasha; Kenealy, Timothy; Herd, Geoff; Eggleton, Kyle; Lightfoot, Rose; Arcus, Kim; Wadham, Angela; Jiang, Yannan; Bullen, Chris
2017-01-01
To assess the effect of a point of care (POC) device for testing lipids and HbA1c in addition to testing by community laboratory facilities (usual practice) on the completion of cardiovascular disease (CVD) risk assessments in general practice. We conducted a pragmatic, cluster randomised controlled trial in 20 New Zealand general practices stratified by size and rurality and randomised to POC device plus usual practice or usual practice alone (controls). Patients aged 35-79 years were eligible if they met national guideline criteria for CVD risk assessment. Data on CVD risk assessments were aggregated using a web-based decision support programme common to each practice. Data entered into the on-line CVD risk assessment form could be saved pending blood test results. The primary outcome was the proportion of completed CVD risk assessments. Qualitative data on practice processes for CVD risk assessment and feasibility of POC testing were collected at the end of the study by interviews and questionnaire. The POC testing was supported by a comprehensive quality assurance programme. A CVD risk assessment entry was recorded for 7421 patients in 10 POC practices and 6217 patients in 10 control practices; 99.5% of CVD risk assessments had complete data in both groups (adjusted odds ratio 1.02 [95%CI 0.61-1.69]). There were major external influences that affected the trial: including a national performance target for CVD risk assessment and changes to CVD guidelines. All practices had invested in systems and dedicated staff time to identify and follow up patients to completion. However, the POC device was viewed by most as an additional tool rather than as an opportunity to review practice work flow and leverage the immediate test results for patient education and CVD risk management discussions. Shortly after commencement, the trial was halted due to a change in the HbA1c test assay performance. The trial restarted after the manufacturing issue was rectified but this affected the end use of the device. Performance incentives and external influences were more powerful modifiers of practice behaviours than the POC device in relation to CVD risk assessment completion. The promise of combining risk assessment, communication and management within one consultation was not realised. With shifts in policy focus, the utility of POC devices for patient engagement in CVD preventive care may be demonstrated if fully integrated into the clinical setting. Australian New Zealand Clinical Trials Registry ACTRN12613000607774.
Comparison of lancing devices for self-monitoring of blood glucose regarding lancing pain.
Kocher, Serge; Tshiananga, J K Tshiang; Koubek, Richard
2009-09-01
Self-monitoring of blood glucose empowers diabetes patients to effectively control their blood glucose (BG) levels. A potential barrier to frequent BG controls is lancing pain, intrinsically linked to pricking the finger several times a day. In this study, we compared different state-of-the-art lancing devices from leading manufacturers regarding lancing pain, and we intended to identify lancing devices that are less painful. First, 165 subjects compared 6 different BG monitoring systems-consisting of a lancing device and a BG meter-at home for 36 days and at least 3 BG tests per day. Second, the subjects directly compared 6 different lancing devices-independent from a BG meter-in a laboratory setting. The test results were collected in questionnaires, and lancing pain was rated on a numerical rating scale. One hundred fifty-seven subjects were included in the analysis. Accu-Chek BG monitoring systems were significantly (p < or = .006) preferred to competitor BG monitoring systems and were rated by >50% of the subjects as "less painful" than competitor BG monitoring systems. Accu-Chek lancing devices were significantly (p < .001) preferred to competitor lancing devices and were rated by >60% of the subjects as "less painful" than competitor lancing devices. We found significant differences in lancing pain between lancing devices. Diabetes patients clearly preferred lancing devices that cause less lancing pain. In order to improve patient compliance with respect to an adequate glycemic control, the medical staff should preferentially prescribe lancing devices that cause less lancing pain. 2009 Diabetes Technology Society.
Novel Approach to Simulate Sleep Apnea Patients for Evaluating Positive Pressure Therapy Devices.
Isetta, Valentina; Montserrat, Josep M; Santano, Raquel; Wimms, Alison J; Ramanan, Dinesh; Woehrle, Holger; Navajas, Daniel; Farré, Ramon
2016-01-01
Bench testing is a useful method to characterize the response of different automatic positive airway pressure (APAP) devices under well-controlled conditions. However, previous models did not consider the diversity of obstructive sleep apnea (OSA) patients' characteristics and phenotypes. The objective of this proof-of-concept study was to design a new bench test for realistically simulating an OSA patient's night, and to implement a one-night example of a typical female phenotype for comparing responses to several currently-available APAP devices. We developed a novel approach aimed at replicating a typical night of sleep which includes different disturbed breathing events, disease severities, sleep/wake phases, body postures and respiratory artefacts. The simulated female OSA patient example that we implemented included periods of wake, light sleep and deep sleep with positional changes and was connected to ten different APAP devices. Flow and pressure readings were recorded; each device was tested twice. The new approach for simulating female OSA patients effectively combined a wide variety of disturbed breathing patterns to mimic the response of a predefined patient type. There were marked differences in response between devices; only three were able to overcome flow limitation to normalize breathing, and only five devices were associated with a residual apnea-hypopnea index of <5/h. In conclusion, bench tests can be designed to simulate specific patient characteristics, and typical stages of sleep, body position, and wake. Each APAP device behaved differently when exposed to this controlled model of a female OSA patient, and should lead to further understanding of OSA treatment.
Development of silicon carbide semiconductor devices for high temperature applications
NASA Technical Reports Server (NTRS)
Matus, Lawrence G.; Powell, J. Anthony; Petit, Jeremy B.
1991-01-01
The semiconducting properties of electronic grade silicon carbide crystals, such as wide energy bandgap, make it particularly attractive for high temperature applications. Applications for high temperature electronic devices include instrumentation for engines under development, engine control and condition monitoring systems, and power conditioning and control systems for space platforms and satellites. Discrete prototype SiC devices were fabricated and tested at elevated temperatures. Grown p-n junction diodes demonstrated very good rectification characteristics at 870 K. A depletion-mode metal-oxide-semiconductor field-effect transistor was also successfully fabricated and tested at 770 K. While optimization of SiC fabrication processes remain, it is believed that SiC is an enabling high temperature electronic technology.
Test strategies for industrial testers for converter controls equipment
NASA Astrophysics Data System (ADS)
Oleniuk, P.; Di Cosmo, M.; Kasampalis, V.; Nisbet, D.; Todd, B.; Uznański, S.
2017-04-01
Power converters and their controls electronics are key elements for the operation of the CERN accelerator complex, having a direct impact on its availability. To prevent early-life failures and provide means to verify electronics, a set of industrial testers is used throughout the converters controls electronics' life cycle. The roles of the testers are to validate mass production during the manufacturing phase and to provide means to diagnose and repair failed modules that are brought back from operation. In the converter controls electronics section of the power converters group in the technology department of CERN (TE/EPC/CCE), two main test platforms have been adopted: a PXI platform for mixed analogue-digital functional tests and a JTAG Boundary-Scan platform for digital interconnection and functional tests. Depending on the functionality of the device under test, the appropriate test platforms are chosen. This paper is a follow-up to results presented at the TWEPP 2015 conference, adding the boundary scan test platform and the first results from exploitation of the test system. This paper reports on the test software, hardware design and test strategy applied for a number of devices that has resulted in maximizing test coverage and minimizing test design effort.
Podcasts on Mobile Devices as a Read-Aloud Testing Accommodation in Middle School Science Assessment
NASA Astrophysics Data System (ADS)
McMahon, Don; Wright, Rachel; Cihak, David F.; Moore, Tara C.; Lamb, Richard
2016-04-01
The purpose of this study was to examine the effect of a digitized podcast to deliver read-aloud testing accommodations on mobile devices to students with disabilities and reading difficulties. The total sample for this study included 47 middle school students with reading difficulties. Of the 47 students, 16 were identified as students with disabilities who received special education services. Participants were randomly assigned to three experimental testing conditions, standard administration, teacher-controlled read-aloud in traditional group delivery format, and student-controlled read-aloud delivered as a podcast and accessed on a mobile device, and given sample end-of-year science assessments. Based on a factorial analysis of variances, with test conditions and student status as the fixed factors, both student groups demonstrated statistically significant gains based on their testing conditions. Results support the use of podcast delivery as a viable alternative to the traditional teacher-delivered read-aloud test accommodation. Conclusions are discussed in the context of universal design for learning testing accommodations for future research and practice.
Robust Control of Wide Bandgap Power Electronics Device Enabled Smart Grid
NASA Astrophysics Data System (ADS)
Yao, Tong
In recent years, wide bandgap (WBG) devices enable power converters with higher power density and higher efficiency. On the other hand, smart grid technologies are getting mature due to new battery technology and computer technology. In the near future, the two technologies will form the next generation of smart grid enabled by WBG devices. This dissertation deals with two applications: silicon carbide (SiC) device used for medium voltage level interface (7.2 kV to 240 V) and gallium nitride (GaN) device used for low voltage level interface (240 V/120 V). A 20 kW solid state transformer (SST) is designed with 6 kHz switching frequency SiC rectifier. Then three robust control design methods are proposed for each of its smart grid operation modes. In grid connected mode, a new LCL filter design method is proposed considering grid voltage THD, grid current THD and current regulation loop robust stability with respect to the grid impedance change. In grid islanded mode, micro synthesis method combined with variable structure control is used to design a robust controller for grid voltage regulation. For grid emergency mode, multivariable controller designed using Hinfinity synthesis method is proposed for accurate power sharing. Controller-hardware-in-the-loop (CHIL) testbed considering 7-SST system is setup with Real Time Digital Simulator (RTDS). The real TMS320F28335 DSP and Spartan 6 FPGA control board is used to interface a switching model SST in RTDS. And the proposed control methods are tested. For low voltage level application, a 3.3 kW smart grid hardware is built with 3 GaN inverters. The inverters are designed with the GaN device characterized using the proposed multi-function double pulse tester. The inverter is controlled by onboard TMS320F28379D dual core DSP with 200 kHz sampling frequency. Each inverter is tested to process 2.2 kW power with overall efficiency of 96.5 % at room temperature. The smart grid monitor system and fault interrupt devices (FID) based on Arduino Mega2560 are built and tested. The smart grid cooperates with GaN inverters through CAN bus communication. At last, the three GaN inverters smart grid achieved the function of grid connected to islanded mode smooth transition.
Open core control software for surgical robots.
Arata, Jumpei; Kozuka, Hiroaki; Kim, Hyung Wook; Takesue, Naoyuki; Vladimirov, B; Sakaguchi, Masamichi; Tokuda, Junichi; Hata, Nobuhiko; Chinzei, Kiyoyuki; Fujimoto, Hideo
2010-05-01
In these days, patients and doctors in operation room are surrounded by many medical devices as resulting from recent advancement of medical technology. However, these cutting-edge medical devices are working independently and not collaborating with each other, even though the collaborations between these devices such as navigation systems and medical imaging devices are becoming very important for accomplishing complex surgical tasks (such as a tumor removal procedure while checking the tumor location in neurosurgery). On the other hand, several surgical robots have been commercialized, and are becoming common. However, these surgical robots are not open for collaborations with external medical devices in these days. A cutting-edge "intelligent surgical robot" will be possible in collaborating with surgical robots, various kinds of sensors, navigation system and so on. On the other hand, most of the academic software developments for surgical robots are "home-made" in their research institutions and not open to the public. Therefore, open source control software for surgical robots can be beneficial in this field. From these perspectives, we developed Open Core Control software for surgical robots to overcome these challenges. In general, control softwares have hardware dependencies based on actuators, sensors and various kinds of internal devices. Therefore, these control softwares cannot be used on different types of robots without modifications. However, the structure of the Open Core Control software can be reused for various types of robots by abstracting hardware dependent parts. In addition, network connectivity is crucial for collaboration between advanced medical devices. The OpenIGTLink is adopted in Interface class which plays a role to communicate with external medical devices. At the same time, it is essential to maintain the stable operation within the asynchronous data transactions through network. In the Open Core Control software, several techniques for this purpose were introduced. Virtual fixture is well known technique as a "force guide" for supporting operators to perform precise manipulation by using a master-slave robot. The virtual fixture for precise and safety surgery was implemented on the system to demonstrate an idea of high-level collaboration between a surgical robot and a navigation system. The extension of virtual fixture is not a part of the Open Core Control system, however, the function such as virtual fixture cannot be realized without a tight collaboration between cutting-edge medical devices. By using the virtual fixture, operators can pre-define an accessible area on the navigation system, and the area information can be transferred to the robot. In this manner, the surgical console generates the reflection force when the operator tries to get out from the pre-defined accessible area during surgery. The Open Core Control software was implemented on a surgical master-slave robot and stable operation was observed in a motion test. The tip of the surgical robot was displayed on a navigation system by connecting the surgical robot with a 3D position sensor through the OpenIGTLink. The accessible area was pre-defined before the operation, and the virtual fixture was displayed as a "force guide" on the surgical console. In addition, the system showed stable performance in a duration test with network disturbance. In this paper, a design of the Open Core Control software for surgical robots and the implementation of virtual fixture were described. The Open Core Control software was implemented on a surgical robot system and showed stable performance in high-level collaboration works. The Open Core Control software is developed to be a widely used platform of surgical robots. Safety issues are essential for control software of these complex medical devices. It is important to follow the global specifications such as a FDA requirement "General Principles of Software Validation" or IEC62304. For following these regulations, it is important to develop a self-test environment. Therefore, a test environment is now under development to test various interference in operation room such as a noise of electric knife by considering safety and test environment regulations such as ISO13849 and IEC60508. The Open Core Control software is currently being developed software in open-source manner and available on the Internet. A communization of software interface is becoming a major trend in this field. Based on this perspective, the Open Core Control software can be expected to bring contributions in this field.
Ohira, Masayuki; Silcox, Jade; Haygood, Deavin; Harper-King, Valerie; Alsharabati, Mohammad; Lu, Liang; Morgan, Marla B; Young, Angela M; Claussen, Gwen C; King, Peter H; Oh, Shin J
2013-01-01
We compared the problems or complications associated with electrodiagnostic testing in 77 patients with implanted cardiac devices. Thirty tests were performed after magnet placement, and 47 were performed without magnet application. All electrodiagnostic tests were performed safely in all patients without any serious effect on the implanted cardiac devices with or without magnet placement. A significantly higher number of patient symptoms and procedure changes were reported in the magnet group (P < 0.013). No statistical difference was found in the testing difficulty or ECG changes. The magnet group patients had an approximately 11-fold greater risk of symptoms than those in the control group. Our data do not support a recommendation that magnet placement is necessary for routine electrodiagnostic testing in patients with implanted cardiac devices, as long as our general and specific guidelines are followed. Copyright © 2012 Wiley Periodicals, Inc.
Compact and portable digitally controlled device for testing footwear materials: technical note.
Foto, James G
2008-01-01
Little or no practical decision-making data are available to the foot-care provider regarding the selection of orthotic materials used in therapeutic footwear. A device for simulating in-shoe forefoot conditions for the testing of orthosis materials is described. Materials are tested for their effectiveness by evaluating and comparing stress-strain and dynamic compression fatigue characteristics. The device, called the Cyclical Compression Tester (CCT), has been optimized for size, simplicity of construction, and cost. Application of the device ranges from the clinician deciding the useful life of single- and multidensity orthosis materials to the researcher characterizing materials for finite-element analysis modeling. This real-time CCT device and custom user interface combine to make an evaluation tool useful for testing how the pressure distribution of in-shoe materials changes over time in therapeutic footwear for those with peripheral neuropathy at risk for foot injury.
Control of a powered prosthetic device via a pinch gesture interface
NASA Astrophysics Data System (ADS)
Yetkin, Oguz; Wallace, Kristi; Sanford, Joseph D.; Popa, Dan O.
2015-06-01
A novel system is presented to control a powered prosthetic device using a gesture tracking system worn on a user's sound hand in order to detect different grasp patterns. Experiments are presented with two different gesture tracking systems: one comprised of Conductive Thimbles worn on each finger (Conductive Thimble system), and another comprised of a glove which leaves the fingers free (Conductive Glove system). Timing tests were performed on the selection and execution of two grasp patterns using the Conductive Thimble system and the iPhone app provided by the manufacturer. A modified Box and Blocks test was performed using Conductive Glove system and the iPhone app provided by Touch Bionics. The best prosthetic device performance is reported with the developed Conductive Glove system in this test. Results show that these low encumbrance gesture-based wearable systems for selecting grasp patterns may provide a viable alternative to EMG and other prosthetic control modalities, especially for new prosthetic users who are not trained in using EMG signals.
Efficacy of new low-cost filtration device for recovering Schistosoma haematobium eggs from urine.
Gyorkos, T W; Ramsan, M; Foum, A; Khamis, I S
2001-07-01
A new, inexpensive filtration device for the diagnosis of urinary schistosomiasis was tested against the commonly used Millipore device. The experimental protocol was performed with 25 urine samples known to be positive for Schistosoma haematobium. The results suggest that the new device is as effective as the Millipore device for the diagnosis of urinary schistosomiasis. Its low cost will be attractive to schistosomiasis control programs.
Design of a gait training device for control of pelvic obliquity.
Pietrusinski, Maciej; Severini, Giacomo; Cajigas, Iahn; Mavroidis, Constantinos; Bonato, Paolo
2012-01-01
This paper presents the design and testing of a novel device for the control of pelvic obliquity during gait. The device, called the Robotic Gait Rehabilitation (RGR) Trainer, consists of a single actuator system designed to target secondary gait deviations, such as hip-hiking, affecting the movement of the pelvis. Secondary gait deviations affecting the pelvis are generated in response to primary gait deviations (e.g. limited knee flexion during the swing phase) in stroke survivors and contribute to the overall asymmetrical gait pattern often observed in these patients. The proposed device generates a force field able to affect the obliquity of the pelvis (i.e. the rotation of the pelvis around the anteroposterior axis) by using an impedance controlled single linear actuator acting on a hip orthosis. Tests showed that the RGR Trainer is able to induce changes in pelvic obliquity trajectories (hip-hiking) in healthy subjects. These results suggest that the RGR Trainer is suitable to test the hypothesis that has motivated our efforts toward developing the system, namely that addressing both primary and secondary gait deviations during robotic-assisted gait training may help promote a physiologically-sound gait behavior more effectively than when only primary deviations are addressed.
21 CFR 862.1305 - Formiminoglutamic acid (FIGLU) test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... measurements obtained by this device are used in the diagnosis of anemias, such as pernicious anemia and congenital hemolytic anemia. (b) Classification. Class I (general controls). The device is exempt from the...
21 CFR 862.1305 - Formiminoglutamic acid (FIGLU) test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... measurements obtained by this device are used in the diagnosis of anemias, such as pernicious anemia and congenital hemolytic anemia. (b) Classification. Class I (general controls). The device is exempt from the...
An open-source framework for testing tracking devices using Lego Mindstorms
NASA Astrophysics Data System (ADS)
Jomier, Julien; Ibanez, Luis; Enquobahrie, Andinet; Pace, Danielle; Cleary, Kevin
2009-02-01
In this paper, we present an open-source framework for testing tracking devices in surgical navigation applications. At the core of image-guided intervention systems is the tracking interface that handles communication with the tracking device and gathers tracking information. Given that the correctness of tracking information is critical for protecting patient safety and for ensuring the successful execution of an intervention, the tracking software component needs to be thoroughly tested on a regular basis. Furthermore, with widespread use of extreme programming methodology that emphasizes continuous and incremental testing of application components, testing design becomes critical. While it is easy to automate most of the testing process, it is often more difficult to test components that require manual intervention such as tracking device. Our framework consists of a robotic arm built from a set of Lego Mindstorms and an open-source toolkit written in C++ to control the robot movements and assess the accuracy of the tracking devices. The application program interface (API) is cross-platform and runs on Windows, Linux and MacOS. We applied this framework for the continuous testing of the Image-Guided Surgery Toolkit (IGSTK), an open-source toolkit for image-guided surgery and shown that regression testing on tracking devices can be performed at low cost and improve significantly the quality of the software.
Operator procedure verification with a rapidly reconfigurable simulator
NASA Technical Reports Server (NTRS)
Iwasaki, Yumi; Engelmore, Robert; Fehr, Gary; Fikes, Richard
1994-01-01
Generating and testing procedures for controlling spacecraft subsystems composed of electro-mechanical and computationally realized elements has become a very difficult task. Before a spacecraft can be flown, mission controllers must envision a great variety of situations the flight crew may encounter during a mission and carefully construct procedures for operating the spacecraft in each possible situation. If, despite extensive pre-compilation of control procedures, an unforeseen situation arises during a mission, the mission controller must generate a new procedure for the flight crew in a limited amount of time. In such situations, the mission controller cannot systematically consider and test alternative procedures against models of the system being controlled, because the available simulator is too large and complex to reconfigure, run, and analyze quickly. A rapidly reconfigurable simulation environment that can execute a control procedure and show its effects on system behavior would greatly facilitate generation and testing of control procedures both before and during a mission. The How Things Work project at Stanford University has developed a system called DME (Device Modeling Environment) for modeling and simulating the behavior of electromechanical devices. DME was designed to facilitate model formulation and behavior simulation of device behavior including both continuous and discrete phenomena. We are currently extending DME for use in testing operator procedures, and we have built a knowledge base for modeling the Reaction Control System (RCS) of the space shuttle as a testbed. We believe that DME can facilitate design of operator procedures by providing mission controllers with a simulation environment that meets all these requirements.
Wireless Coexistence and EMC of Bluetooth and 802.11b Devices in Controlled Laboratory Settings
Seidman, Seth; Kainz, Wolfgang; Ruggera, Paul; Mendoza, Gonzalo
2011-01-01
This paper presents experimental testing that has been performed on wireless communication devices as victims of electromagnetic interference (EMI). Wireless victims included universal serial bus (USB) network adapters and personal digital assistants (PDAs) equipped with IEEE 802.11b and Bluetooth technologies. The experimental data in this paper was gathered in an anechoic chamber and a gigahertz transverse electromagnetic (GTEM) cell to ensure reliable and repeatable results. This testing includes: Electromagnetic compatibility (EMC) testing performed in accordance with IEC 60601-1-2, an in-band sweep of EMC testing, and coexistence testing. The tests in this study show that a Bluetooth communication was able to coexist with other Bluetooth devices with no decrease in throughput and no communication breakdowns. However, testing revealed a significant decrease in throughput and increase in communication breakdowns when an 802.11b source is near an 802.11b victim. In a hospital setting decreased throughput and communication breakdowns can cause wireless medical devices to fail. It is therefore vital to have an understanding of the effect EMI can have on wireless communication devices. PMID:22043254
Wireless Coexistence and EMC of Bluetooth and 802.11b Devices in Controlled Laboratory Settings.
Seidman, Seth; Kainz, Wolfgang; Ruggera, Paul; Mendoza, Gonzalo
2011-01-01
This paper presents experimental testing that has been performed on wireless communication devices as victims of electromagnetic interference (EMI). Wireless victims included universal serial bus (USB) network adapters and personal digital assistants (PDAs) equipped with IEEE 802.11b and Bluetooth technologies. The experimental data in this paper was gathered in an anechoic chamber and a gigahertz transverse electromagnetic (GTEM) cell to ensure reliable and repeatable results. This testing includes: Electromagnetic compatibility (EMC) testing performed in accordance with IEC 60601-1-2, an in-band sweep of EMC testing, and coexistence testing. The tests in this study show that a Bluetooth communication was able to coexist with other Bluetooth devices with no decrease in throughput and no communication breakdowns. However, testing revealed a significant decrease in throughput and increase in communication breakdowns when an 802.11b source is near an 802.11b victim. In a hospital setting decreased throughput and communication breakdowns can cause wireless medical devices to fail. It is therefore vital to have an understanding of the effect EMI can have on wireless communication devices.
Kencana, Andy Prima; Heng, John
2008-11-01
This paper introduces a novel passive tongue control and tracking device. The device is intended to be used by the severely disabled or quadriplegic person. The main focus of this device when compared to the other existing tongue tracking devices is that the sensor employed is passive which means it requires no powered electrical sensor to be inserted into the user's mouth and hence no trailing wires. This haptic interface device employs the use of inductive sensors to track the position of the user's tongue. The device is able perform two main PC functions that of the keyboard and mouse function. The results show that this device allows the severely disabled person to have some control in his environment, such as to turn on and off or control daily electrical devices or appliances; or to be used as a viable PC Human Computer Interface (HCI) by tongue control. The operating principle and set-up of such a novel passive tongue HCI has been established with successful laboratory trials and experiments. Further clinical trials will be required to test out the device on disabled persons before it is ready for future commercial development.
NASA Technical Reports Server (NTRS)
Tucker, Warren A.; Comisarow, Paul
1946-01-01
During the first flight tests of the Republic XP-84 airplane it was discovered that there was a complete lack of stall warning. A short series of development tests of a suitable stall-warning device for the airplane was therefore made on a 1/5-scale model in the Langley 300 MPH 7- by 10-foot tunnel. Two similar stall-warning devices, each designed to produce early root stall which would provide a buffet warning, were tested. It appeared that either device would give a satisfactory buffet warning in the flap-up configuration, at the cost of an increase of 8 or 10 miles per hour in minimum speed. Although neither device seemed to give a true buffet warning in the flaps-down configuration, it appeared that either device would improve the flaps-down stalling characteristics by lessening the severity of the stall and by maintaining better control at the stall. The flaps-down minimum-speed increase caused by the devices was only 1 or 2 miles per hour.
Comparison of Lancing Devices for Self-Monitoring of Blood Glucose Regarding Lancing Pain
Kocher, Serge; Tshiananga, J. K. Tshiang; Koubek, Richard
2009-01-01
Background Self-monitoring of blood glucose empowers diabetes patients to effectively control their blood glucose (BG) levels. A potential barrier to frequent BG controls is lancing pain, intrinsically linked to pricking the finger several times a day. In this study, we compared different state-of-the-art lancing devices from leading manufacturers regarding lancing pain, and we intended to identify lancing devices that are less painful. Methods First, 165 subjects compared 6 different BG monitoring systems—consisting of a lancing device and a BG meter—at home for 36 days and at least 3 BG tests per day. Second, the subjects directly compared 6 different lancing devices—independent from a BG meter—in a laboratory setting. The test results were collected in questionnaires, and lancing pain was rated on a numerical rating scale. Results One hundred fifty-seven subjects were included in the analysis. Accu-Chek BG monitoring systems were significantly (p ≤ .006) preferred to competitor BG monitoring systems and were rated by >50% of the subjects as “less painful” than competitor BG monitoring systems. Accu-Chek lancing devices were significantly (p < .001) preferred to competitor lancing devices and were rated by >60% of the subjects as “less painful” than competitor lancing devices. Conclusions We found significant differences in lancing pain between lancing devices. Diabetes patients clearly preferred lancing devices that cause less lancing pain. In order to improve patient compliance with respect to an adequate glycemic control, the medical staff should preferentially prescribe lancing devices that cause less lancing pain. PMID:20144427
Integrated otpical monitoring of MEMS for closed-loop control
NASA Astrophysics Data System (ADS)
Dawson, Jeremy M.; Wang, Limin; McCormick, W. B.; Rittenhouse, S. A.; Famouri, Parviz F.; Hornak, Lawrence A.
2003-01-01
Robust control and failure assessment of MEMS employed in physically demanding, mission critical applications will allow for higher degrees of quality assurance in MEMS operation. Device fault detection and closed-loop control require detailed knowledge of the operational states of MEMS over the lifetime of the device, obtained by a means decoupled from the system. Preliminary through-wafer optical monitoring research efforts have shown that through-wafer optical probing is suitable for characterizing and monitoring the behavior of MEMS, and can be implemented in an integrated optical monitoring package for continuous in-situ device monitoring. This presentation will discuss research undertaken to establish integrated optical device metrology for closed-loop control of a MUMPS fabricated lateral harmonic oscillator. Successful linear closed-loop control results using a through-wafer optical microprobe position feedback signal will be presented. A theoretical optical output field intensity study of grating structures, fabricated on the shuttle of the resonator, was performed to improve the position resolution of the optical microprobe position signal. Through-wafer microprobe signals providing a positional resolution of 2 μm using grating structures will be shown, along with initial binary Fresnel diffractive optical microelement design layout, process development, and testing results. Progress in the design, fabrication, and test of integrated optical elements for multiple microprobe signal delivery and recovery will be discussed, as well as simulation of device system model parameter changes for failure assessment.
NASA Technical Reports Server (NTRS)
Brown, B Porter; Chilton, Robert G; Whitten, James B
1952-01-01
Report presents the results of measurements of the longitudinal stability and control characteristics of a large airplane using a mechanical feel device in combination with a booster incorporated in the elevator-control system. Tests were made to investigate the feasibility of eliminating the aerodynamic control forces through use of a booster and of providing control-feel forces mechanically. The feel device consisted of a centering spring which restrained the control stick through a linkage which was changed as a function of the dynamic pressure. Provisions were made for trimming and for manual adjustment of the force gradient. The system was designed to approximate the control-force characteristics that would result with a conventional elevator control with linear hinge-moment characteristics.
40 CFR 63.3100 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2013 CFR
2013-07-01
... be in compliance with the operating limits for emission capture systems and add-on control devices...) You must maintain a log detailing the operation and maintenance of the emission capture systems, add... capture system and add-on control device performance tests have been completed, as specified in § 63.3160...
40 CFR 63.3100 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2014 CFR
2014-07-01
... be in compliance with the operating limits for emission capture systems and add-on control devices...) You must maintain a log detailing the operation and maintenance of the emission capture systems, add... capture system and add-on control device performance tests have been completed, as specified in § 63.3160...
40 CFR 63.3100 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2012 CFR
2012-07-01
... be in compliance with the operating limits for emission capture systems and add-on control devices...) You must maintain a log detailing the operation and maintenance of the emission capture systems, add... capture system and add-on control device performance tests have been completed, as specified in § 63.3160...
40 CFR 63.9020 - What performance tests and other procedures must I use?
Code of Federal Regulations, 2010 CFR
2010-07-01
... CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Hydrochloric Acid Production... where: Ci, Co = Concentration of HCl or Cl2 in the gas stream at the inlet and outlet of the control...-mole. Qi, Qo = Flow rate of gas stream at the inlet and outlet of the control device(s), respectively...
Yousif, Aziz; Kelly, Shawn K
2016-08-01
There has been a push for a greater number of channels in implantable neuroprosthetic devices; but, that number has largely been limited by current hermetic packaging technology. Microfabricated packaging is becoming reality, but a standard testing system is needed to prepare these devices for clinical trials. Impedance measurements of electrodes built into the packaging layers may give an early warning of device failure and predict device lifetime. Because the impedance magnitudes of such devices can be on the order of gigaohms, a versatile system was designed to accommodate ultra-high impedances and allow future integrated circuit implementation in current neural prosthetic technologies. Here we present the circuitry, control software, and preliminary testing results of our designed system.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control Devices As required in § 63.5850 you must conduct performance tests, performance evaluations, and design...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control... Performance Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control Devices As required in § 63.5850 you must conduct performance tests, performance evaluations, and...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control... Performance Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control Devices As required in § 63.5850 you must conduct performance tests, performance evaluations, and...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control... Performance Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control Devices As required in § 63.5850 you must conduct performance tests, performance evaluations, and...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control Devices As required in § 63.5850 you must conduct performance tests, performance evaluations, and design...
Evaluation of an eye-pointer interaction device for human-computer interaction.
Cáceres, Enrique; Carrasco, Miguel; Ríos, Sebastián
2018-03-01
Advances in eye-tracking technology have led to better human-computer interaction, and involve controlling a computer without any kind of physical contact. This research describes the transformation of a commercial eye-tracker for use as an alternative peripheral device in human-computer interactions, implementing a pointer that only needs the eye movements of a user facing a computer screen, thus replacing the need to control the software by hand movements. The experiment was performed with 30 test individuals who used the prototype with a set of educational videogames. The results show that, although most of the test subjects would prefer a mouse to control the pointer, the prototype tested has an empirical precision similar to that of the mouse, either when trying to control its movements or when attempting to click on a point of the screen.
NASA Astrophysics Data System (ADS)
Jaksic, V.; Wright, C.; Chanayil, Afeef; Faruque Ali, Shaikh; Murphy, Jimmy; Pakrashi, Vikram
2015-07-01
Tuned liquid column dampers have been proved to be successful in mitigating the dynamic responses of civil infrastructure. There have been some recent applications of this concept on wind turbines and this passive control system can help to mitigate responses of offshore floating platforms and wave devices. The control of dynamic responses of these devices is important for reducing loads on structural elements and facilitating operations and maintenance (O&M) activities. This paper outlines the use of a tuned single liquid column damper for the control of a tension leg platform supported wind turbine. Theoretical studies were carried out and a scaled model was tested in a wave basin to assess the performance of the damper. The tests on the model presented in this paper correspond to a platform with a very low natural frequency for surge, sway and yaw motions. For practical purposes, it was not possible to tune the liquid damper exactly to this frequency. The consequent approach taken and the efficiency of such approach are presented in this paper. Responses to waves of a single frequency are investigated along with responses obtained from wave spectra characterising typical sea states. The extent of control is quantified using peak and root mean squared dynamic responses respectively. The tests present some guidelines and challenges for testing scaled devices in relation to including response control mechanisms. Additionally, the results provide a basis for dictating future research on tuned liquid column damper based control on floating platforms.
NASA Astrophysics Data System (ADS)
1981-12-01
Test data were collected on 1035 plastic encapsulated devices and 75 hermetically scaled control group devices that were purchased from each of five different manufacturers in the categories of (1) low power Schottsky TTL (bipolar) digital circuits; (2) CMOS digital circuits; (3) operational amplifier linear circuits; and (4) NPN transistors. These parts were subjected to three different initial screening conditions, then to extended life testing, to determine any possible advantages or trends for any particular screen. Several tests were carried out in the areas of flammability testing, humidity testing, high pressure steam (auroclave) testing, and high temperature storage testing. Test results are presented. Procurement and application considerations for use of plastic encapsulated semiconductors are presented and a statistical analysis program written to study the log normal distributions resulting from life testing is concluded.
NASA Technical Reports Server (NTRS)
1981-01-01
Test data were collected on 1035 plastic encapsulated devices and 75 hermetically scaled control group devices that were purchased from each of five different manufacturers in the categories of (1) low power Schottsky TTL (bipolar) digital circuits; (2) CMOS digital circuits; (3) operational amplifier linear circuits; and (4) NPN transistors. These parts were subjected to three different initial screening conditions, then to extended life testing, to determine any possible advantages or trends for any particular screen. Several tests were carried out in the areas of flammability testing, humidity testing, high pressure steam (auroclave) testing, and high temperature storage testing. Test results are presented. Procurement and application considerations for use of plastic encapsulated semiconductors are presented and a statistical analysis program written to study the log normal distributions resulting from life testing is concluded.
NASA Technical Reports Server (NTRS)
MacLeond, Todd C.; Sims, W. Herb; Varnavas,Kosta A.; Ho, Fat D.
2011-01-01
The Memory Test Experiment is a space test of a ferroelectric memory device on a low Earth orbit satellite that launched in November 2010. The memory device being tested is a commercial Ramtron Inc. 512K memory device. The circuit was designed into the satellite avionics and is not used to control the satellite. The test consists of writing and reading data with the ferroelectric based memory device. Any errors are detected and are stored on board the satellite. The data is sent to the ground through telemetry once a day. Analysis of the data can determine the kind of error that was found and will lead to a better understanding of the effects of space radiation on memory systems. The test is one of the first flight demonstrations of ferroelectric memory in a near polar orbit which allows testing in a varied radiation environment. The initial data from the test is presented. This paper details the goals and purpose of this experiment as well as the development process. The process for analyzing the data to gain the maximum understanding of the performance of the ferroelectric memory device is detailed.
van der Togt, Remko; van Lieshout, Erik Jan; Hensbroek, Reinout; Beinat, E; Binnekade, J M; Bakker, P J M
2008-06-25
Health care applications of autoidentification technologies, such as radio frequency identification (RFID), have been proposed to improve patient safety and also the tracking and tracing of medical equipment. However, electromagnetic interference (EMI) by RFID on medical devices has never been reported. To assess and classify incidents of EMI by RFID on critical care equipment. Without a patient being connected, EMI by 2 RFID systems (active 125 kHz and passive 868 MHz) was assessed under controlled conditions during May 2006, in the proximity of 41 medical devices (in 17 categories, 22 different manufacturers) at the Academic Medical Centre, University of Amsterdam, Amsterdam, The Netherlands. Assessment took place according to an international test protocol. Incidents of EMI were classified according to a critical care adverse events scale as hazardous, significant, or light. In 123 EMI tests (3 per medical device), RFID induced 34 EMI incidents: 22 were classified as hazardous, 2 as significant, and 10 as light. The passive 868-MHz RFID signal induced a higher number of incidents (26 incidents in 41 EMI tests; 63%) compared with the active 125-kHz RFID signal (8 incidents in 41 EMI tests; 20%); difference 44% (95% confidence interval, 27%-53%; P < .001). The passive 868-MHz RFID signal induced EMI in 26 medical devices, including 8 that were also affected by the active 125-kHz RFID signal (26 in 41 devices; 63%). The median distance between the RFID reader and the medical device in all EMI incidents was 30 cm (range, 0.1-600 cm). In a controlled nonclinical setting, RFID induced potentially hazardous incidents in medical devices. Implementation of RFID in the critical care environment should require on-site EMI tests and updates of international standards.
Efficacy of New Low-Cost Filtration Device for Recovering Schistosoma haematobium Eggs from Urine
Gyorkos, Theresa W.; Ramsan, Mahdi; Foum, Ali; Khamis, Iddi Simba
2001-01-01
A new, inexpensive filtration device for the diagnosis of urinary schistosomiasis was tested against the commonly used Millipore device. The experimental protocol was performed with 25 urine samples known to be positive for Schistosoma haematobium. The results suggest that the new device is as effective as the Millipore device for the diagnosis of urinary schistosomiasis. Its low cost will be attractive to schistosomiasis control programs. PMID:11427595
Zheng, Song; Zhang, Qi; Zheng, Rong; Huang, Bi-Qin; Song, Yi-Lin; Chen, Xin-Chu
2017-01-01
In recent years, the smart home field has gained wide attention for its broad application prospects. However, families using smart home systems must usually adopt various heterogeneous smart devices, including sensors and devices, which makes it more difficult to manage and control their home system. How to design a unified control platform to deal with the collaborative control problem of heterogeneous smart devices is one of the greatest challenges in the current smart home field. The main contribution of this paper is to propose a universal smart home control platform architecture (IAPhome) based on a multi-agent system and communication middleware, which shows significant adaptability and advantages in many aspects, including heterogeneous devices connectivity, collaborative control, human-computer interaction and user self-management. The communication middleware is an important foundation to design and implement this architecture which makes it possible to integrate heterogeneous smart devices in a flexible way. A concrete method of applying the multi-agent software technique to solve the integrated control problem of the smart home system is also presented. The proposed platform architecture has been tested in a real smart home environment, and the results indicate that the effectiveness of our approach for solving the collaborative control problem of different smart devices. PMID:28926957
Zheng, Song; Zhang, Qi; Zheng, Rong; Huang, Bi-Qin; Song, Yi-Lin; Chen, Xin-Chu
2017-09-16
In recent years, the smart home field has gained wide attention for its broad application prospects. However, families using smart home systems must usually adopt various heterogeneous smart devices, including sensors and devices, which makes it more difficult to manage and control their home system. How to design a unified control platform to deal with the collaborative control problem of heterogeneous smart devices is one of the greatest challenges in the current smart home field. The main contribution of this paper is to propose a universal smart home control platform architecture (IAPhome) based on a multi-agent system and communication middleware, which shows significant adaptability and advantages in many aspects, including heterogeneous devices connectivity, collaborative control, human-computer interaction and user self-management. The communication middleware is an important foundation to design and implement this architecture which makes it possible to integrate heterogeneous smart devices in a flexible way. A concrete method of applying the multi-agent software technique to solve the integrated control problem of the smart home system is also presented. The proposed platform architecture has been tested in a real smart home environment, and the results indicate that the effectiveness of our approach for solving the collaborative control problem of different smart devices.
Design, Fabrication, and In Vitro Testing of an Anti-biofouling Glaucoma Micro-shunt.
Harake, Ryan S; Ding, Yuzhe; Brown, J David; Pan, Tingrui
2015-10-01
Glaucoma, one of the leading causes of irreversible blindness, is a progressive neurodegenerative disease. Chronic elevated intraocular pressure (IOP), a prime risk factor for glaucoma, can be treated by aqueous shunts, implantable devices, which reduce IOP in glaucoma patients by providing alternative aqueous outflow pathways. Although initially effective at delaying glaucoma progression, contemporary aqueous shunts often lead to numerous complications and only 50% of implanted devices remain functional after 5 years. In this work, we introduce a novel micro-device which provides an innovative platform for IOP reduction in glaucoma patients. The device design features an array of parallel micro-channels to provide precision aqueous outflow resistance control. Additionally, the device's microfluidic channels are composed of a unique combination of polyethylene glycol materials in order to provide enhanced biocompatibility and resistance to problematic channel clogging from biofouling of aqueous proteins. The microfabrication process employed to produce the devices results in additional advantages such as enhanced device uniformity and increased manufacturing throughput. Surface characterization experimental results show the device's surfaces exhibit significantly less non-specific protein adsorption compared to traditional implant materials. Results of in vitro flow experiments verify the device's ability to provide aqueous resistance control, continuous long-term stability through 10-day protein flow testing, and safety from risk of infection due to bacterial ingression.
46 CFR 62.25-25 - Programmable systems and devices.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 2 2014-10-01 2014-10-01 false Programmable systems and devices. 62.25-25 Section 62.25... AUTOMATION General Requirements for All Automated Vital Systems § 62.25-25 Programmable systems and devices. (a) Programmable control or alarm system logic must not be altered after Design Verification testing...
Bench test evaluation of adaptive servoventilation devices for sleep apnea treatment.
Zhu, Kaixian; Kharboutly, Haissam; Ma, Jianting; Bouzit, Mourad; Escourrou, Pierre
2013-09-15
Adaptive servoventilation devices are marketed to overcome sleep disordered breathing with apneas and hypopneas of both central and obstructive mechanisms often experienced by patients with chronic heart failure. The clinical efficacy of these devices is still questioned. This study challenged the detection and treatment capabilities of the three commercially available adaptive servoventilation devices in response to sleep disordered breathing events reproduced on an innovative bench test. The bench test consisted of a computer-controlled piston and a Starling resistor. The three devices were subjected to a flow sequence composed of central and obstructive apneas and hypopneas including Cheyne-Stokes respiration derived from a patient. The responses of the devices were separately evaluated with the maximum and the clinical settings (titrated expiratory positive airway pressure), and the detected events were compared to the bench-scored values. The three devices responded similarly to central events, by increasing pressure support to raise airflow. All central apneas were eliminated, whereas hypopneas remained. The three devices responded differently to the obstructive events with the maximum settings. These obstructive events could be normalized with clinical settings. The residual events of all the devices were scored lower than bench test values with the maximum settings, but were in agreement with the clinical settings. However, their mechanisms were misclassified. The tested devices reacted as expected to the disordered breathing events, but not sufficiently to normalize the breathing flow. The device-scored results should be used with caution to judge efficacy, as their validity depends upon the initial settings.
Human Machine Interface Programming and Testing
NASA Technical Reports Server (NTRS)
Foster, Thomas Garrison
2013-01-01
Human Machine Interface (HMI) Programming and Testing is about creating graphical displays to mimic mission critical ground control systems in order to provide NASA engineers with the ability to monitor the health management of these systems in real time. The Health Management System (HMS) is an online interactive human machine interface system that monitors all Kennedy Ground Control Subsystem (KGCS) hardware in the field. The Health Management System is essential to NASA engineers because it allows remote control and monitoring of the health management systems of all the Programmable Logic Controllers (PLC) and associated field devices. KGCS will have equipment installed at the launch pad, Vehicle Assembly Building, Mobile Launcher, as well as the Multi-Purpose Processing Facility. I am designing graphical displays to monitor and control new modules that will be integrated into the HMS. The design of the display screen will closely mimic the appearance and functionality of the actual modules. There are many different field devices used to monitor health management and each device has its own unique set of health management related data, therefore each display must also have its own unique way to display this data. Once the displays are created, the RSLogix5000 application is used to write software that maps all the required data read from the hardware to the graphical display. Once this data is mapped to its corresponding display item, the graphical display and hardware device will be connected through the same network in order to test all possible scenarios and types of data the graphical display was designed to receive. Test Procedures will be written to thoroughly test out the displays and ensure that they are working correctly before being deployed to the field. Additionally, the Kennedy Ground Controls Subsystem's user manual will be updated to explain to the NASA engineers how to use the new module displays.
Hydrodynamics-induced variability in the USP apparatus II dissolution test.
Baxter, Jennifer L; Kukura, Joseph; Muzzio, Fernando J
2005-03-23
The USP tablet dissolution test is an analytical tool used for the verification of drug release processes and formulation selection within the pharmaceutical industry. Given the strong impact of this test, it is surprising that operating conditions and testing devices have been selected empirically. In fact, the flow phenomena in the USP test have received little attention in the past. An examination of the hydrodynamics in the USP apparatus II shows that the device is highly vulnerable to mixing problems that can affect testing performance and consistency. Experimental and computational techniques reveal that the flow field within the device is not uniform, and dissolution results can vary dramatically with the position of the tablet within the vessel. Specifically, computations predict sharp variations in the shear along the bottom of the vessel where the tablet is most likely to settle. Experiments in which the tablet location was carefully controlled reveal that the variation of shear within the testing device can affect the measured dissolution rate.
Remote telescope control of site testing with ASCOM
NASA Astrophysics Data System (ADS)
Ji, Kaifan; Liang, Bo; Peng, Yajie; Wang, Feng
2012-04-01
Remote telescope control is significant important for the astronomical site testing. Basing on ASCOM standard, a prototype of remote telescope control system has been implemented. In this paper, the details of the system design, both server end and client end, are introduced. We tested the prototype on a narrow-band dial-up networking and controlled a real remote telescope successfully. The result indicates that it is effective to control remote telescope and other devices with ASCOM.
Lee, Kichol; Casali, John G
2017-01-01
To design a test battery and conduct a proof-of-concept experiment of a test method that can be used to measure the detection performance afforded by military advanced hearing protection devices (HPDs) and tactical communication and protective systems (TCAPS). The detection test was conducted with each of the four loudspeakers located at front, right, rear and left of the participant. Participants wore 2 in-ear-type TCAPS, 1 earmuff-type TCAPS, a passive Combat Arms Earplug in its "open" or pass-through setting and an EB-15LE™ electronic earplug. Devices with electronic gain systems were tested under two gain settings: "unity" and "max". Testing without any device (open ear) was conducted as a control. Ten participants with audiometric requirements of 25 dBHL or better at 500, 1000, 2000, 4000, 8000 Hz in both ears. Detection task performance varied with different signals and speaker locations. The test identified performance differences among certain TCAPS and protectors, and the open ear. A computer-controlled detection subtest of the Detection-Recognition/Identification-Localisation-Communication (DRILCOM) test battery was designed and implemented. Tested in a proof-of-concept experiment, it showed statistically-significant sensitivity to device differences in detection effects with the small sample of participants (10). This result has important implications for selection and deployment of TCAPS and HPDs on soldiers and workers in dynamic situations.
Lee, Kichol; Casali, John G
2016-01-01
To investigate the effect of controlled low-speed wind-noise on the auditory situation awareness performance afforded by military hearing protection/enhancement devices (HPED) and tactical communication and protective systems (TCAPS). Recognition/identification and pass-through communications tasks were separately conducted under three wind conditions (0, 5, and 10 mph). Subjects wore two in-ear-type TCAPS, one earmuff-type TCAPS, a Combat Arms Earplug in its 'open' or pass-through setting, and an EB-15LE electronic earplug. Devices with electronic gain systems were tested under two gain settings: 'unity' and 'max'. Testing without any device (open ear) was conducted as a control. Ten subjects were recruited from the student population at Virginia Tech. Audiometric requirements were 25 dBHL or better at 500, 1000, 2000, 4000, and 8000 Hz in both ears. Performance on the interaction of communication task-by-device was significantly different only in 0 mph wind speed. The between-device performance differences varied with azimuthal speaker locations. It is evident from this study that stable (non-gusting) wind speeds up to 10 mph did not significantly degrade recognition/identification task performance and pass-through communication performance of the group of HPEDs and TCAPS tested. However, the various devices performed differently as the test sound signal speaker location was varied and it appears that physical as well as electronic features may have contributed to this directional result.
Digital Platform for Wafer-Level MEMS Testing and Characterization Using Electrical Response
Brito, Nuno; Ferreira, Carlos; Alves, Filipe; Cabral, Jorge; Gaspar, João; Monteiro, João; Rocha, Luís
2016-01-01
The uniqueness of microelectromechanical system (MEMS) devices, with their multiphysics characteristics, presents some limitations to the borrowed test methods from traditional integrated circuits (IC) manufacturing. Although some improvements have been performed, this specific area still lags behind when compared to the design and manufacturing competencies developed over the last decades by the IC industry. A complete digital solution for fast testing and characterization of inertial sensors with built-in actuation mechanisms is presented in this paper, with a fast, full-wafer test as a leading ambition. The full electrical approach and flexibility of modern hardware design technologies allow a fast adaptation for other physical domains with minimum effort. The digital system encloses a processor and the tailored signal acquisition, processing, control, and actuation hardware control modules, capable of the structure position and response analysis when subjected to controlled actuation signals in real time. The hardware performance, together with the simplicity of the sequential programming on a processor, results in a flexible and powerful tool to evaluate the newest and fastest control algorithms. The system enables measurement of resonant frequency (Fr), quality factor (Q), and pull-in voltage (Vpi) within 1.5 s with repeatability better than 5 ppt (parts per thousand). A full-wafer with 420 devices under test (DUTs) has been evaluated detecting the faulty devices and providing important design specification feedback to the designers. PMID:27657087
Digital Platform for Wafer-Level MEMS Testing and Characterization Using Electrical Response.
Brito, Nuno; Ferreira, Carlos; Alves, Filipe; Cabral, Jorge; Gaspar, João; Monteiro, João; Rocha, Luís
2016-09-21
The uniqueness of microelectromechanical system (MEMS) devices, with their multiphysics characteristics, presents some limitations to the borrowed test methods from traditional integrated circuits (IC) manufacturing. Although some improvements have been performed, this specific area still lags behind when compared to the design and manufacturing competencies developed over the last decades by the IC industry. A complete digital solution for fast testing and characterization of inertial sensors with built-in actuation mechanisms is presented in this paper, with a fast, full-wafer test as a leading ambition. The full electrical approach and flexibility of modern hardware design technologies allow a fast adaptation for other physical domains with minimum effort. The digital system encloses a processor and the tailored signal acquisition, processing, control, and actuation hardware control modules, capable of the structure position and response analysis when subjected to controlled actuation signals in real time. The hardware performance, together with the simplicity of the sequential programming on a processor, results in a flexible and powerful tool to evaluate the newest and fastest control algorithms. The system enables measurement of resonant frequency (Fr), quality factor (Q), and pull-in voltage (Vpi) within 1.5 s with repeatability better than 5 ppt (parts per thousand). A full-wafer with 420 devices under test (DUTs) has been evaluated detecting the faulty devices and providing important design specification feedback to the designers.
Portelli, Andrew; Reid, Susan A
2018-02-01
The purpose of this study was to evaluate if young people with insidious-onset neck pain who spend long periods on mobile electronic devices (known as "text neck") have impaired cervical proprioception and if this is related to time on devices. A 2-group comparative observational study was conducted at an Australian university. Twenty-two participants with text neck and 22 asymptomatic controls, all of whom were 18 to 35 years old and spent ≥4 hours per day on unsupported electronic devices, were assessed using the head repositioning accuracy (HRA) test. Differences between groups were calculated using independent sample t-tests, and correlations between neck pain intensity, time on devices, and HRA test were performed using Pearson's bivariate analysis. During cervical flexion, those with text neck (n = 22, mean age ± standard deviation [SD]: 21 ± 4 years, 59% female) had a 3.9° (SD: 1.4°) repositioning error, and the control group (n = 22, 20 ± 1 years, 68% female) had a 2.9° (SD: 1.2°) error. The mean difference was 1° (95% confidence interval: 0-2, P = .02). For other cervical movements, there was no difference between groups. There was a moderately significant correlation (P ≤ .05) between time spent on electronic devices and cervical pain intensity and between cervical pain intensity and HRA during flexion. The participants with text neck had a greater proprioceptive error during cervical flexion compared with controls. This could be related to neck pain and time spent on electronic devices. Copyright © 2018. Published by Elsevier Inc.
Enhanced Control for Local Helicity Injection on the Pegasus ST
NASA Astrophysics Data System (ADS)
Pierren, C.; Bongard, M. W.; Fonck, R. J.; Lewicki, B. T.; Perry, J. M.
2017-10-01
Local helicity injection (LHI) experiments on Pegasus rely upon programmable control of a 250 MVA modular power supply system that drives the electromagnets and helicity injection systems. Precise control of the central solenoid is critical to experimental campaigns that test the LHI Taylor relaxation limit and the coupling efficiency of LHI-produced plasmas to Ohmic current drive. Enhancement and expansion of the present control system is underway using field programmable gate array (FPGA) technology for digital logic and control, coupled to new 10 MHz optical-to-digital transceivers for semiconductor level device communication. The system accepts optical command signals from existing analog feedback controllers, transmits them to multiple devices in parallel H-bridges, and aggregates their status signals for fault detection. Present device-level multiplexing/de-multiplexing and protection logic is extended to include bridge-level protections with the FPGA. An input command filter protects against erroneous and/or spurious noise generated commands that could otherwise cause device failures. Fault registration and response times with the FPGA system are 25 ns. Initial system testing indicates an increased immunity to power supply induced noise, enabling plasma operations at higher working capacitor bank voltage. This can increase the applied helicity injection drive voltage, enable longer pulse lengths and improve Ohmic loop voltage control. Work supported by US DOE Grant DE-FG02-96ER54375.
Data processing device test apparatus and method therefor
Wilcox, Richard Jacob; Mulig, Jason D.; Eppes, David; Bruce, Michael R.; Bruce, Victoria J.; Ring, Rosalinda M.; Cole, Jr., Edward I.; Tangyunyong, Paiboon; Hawkins, Charles F.; Louie, Arnold Y.
2003-04-08
A method and apparatus mechanism for testing data processing devices are implemented. The test mechanism isolates critical paths by correlating a scanning microscope image with a selected speed path failure. A trigger signal having a preselected value is generated at the start of each pattern vector. The sweep of the scanning microscope is controlled by a computer, which also receives and processes the image signals returned from the microscope. The value of the trigger signal is correlated with a set of pattern lines being driven on the DUT. The trigger is either asserted or negated depending the detection of a pattern line failure and the particular line that failed. In response to the detection of the particular speed path failure being characterized, and the trigger signal, the control computer overlays a mask on the image of the device under test (DUT). The overlaid image provides a visual correlation of the failure with the structural elements of the DUT at the level of resolution of the microscope itself.
A Novel Small-Specimen Planar Biaxial Testing System With Full In-Plane Deformation Control.
Potter, Samuel; Graves, Jordan; Drach, Borys; Leahy, Thomas; Hammel, Chris; Feng, Yuan; Baker, Aaron; Sacks, Michael S
2018-05-01
Simulations of soft tissues require accurate and robust constitutive models, whose form is derived from carefully designed experimental studies. For such investigations of membranes or thin specimens, planar biaxial systems have been used extensively. Yet, all such systems remain limited in their ability to: (1) fully prescribe in-plane deformation gradient tensor F2D, (2) ensure homogeneity of the applied deformation, and (3) be able to accommodate sufficiently small specimens to ensure a reasonable degree of material homogeneity. To address these issues, we have developed a novel planar biaxial testing device that overcomes these difficulties and is capable of full control of the in-plane deformation gradient tensor F2D and of testing specimens as small as ∼4 mm × ∼4 mm. Individual actuation of the specimen attachment points, combined with a robust real-time feedback control, enabled the device to enforce any arbitrary F2D with a high degree of accuracy and homogeneity. Results from extensive device validation trials and example tissues illustrated the ability of the device to perform as designed and gather data needed for developing and validating constitutive models. Examples included the murine aortic tissues, allowing for investigators to take advantage of the genetic manipulation of murine disease models. These capabilities highlight the potential of the device to serve as a platform for informing and verifying the results of inverse models and for conducting robust, controlled investigation into the biomechanics of very local behaviors of soft tissues and membrane biomaterials.
Prehospital Emergency Inguinal Clamp Controls Hemorrhage in Cadaver Model
2013-07-01
fit at anatomic pressure points needed in hemorrhage control. The CRoC was placed on trauma manikins at the U.S. Army Med- ical Department Center and...simulant was pumped to quantify device effective- ness in testing. Points of application included proximal pressure point control of popliteal...a casualty’s wound from the point of injury on the battlefield to the emergency department has been impractical; so a device was made to replace the
CFD Analysis of a T-38 Wing Fence
2007-06-01
or making major adjustments to the existing airframe. The answer lies in flow control. Flow control devices like vortex generators, winglets , and wing...proposed by the Air Force Test Pilot School. The driving force for considering a wing fence as opposed to vane vortex generators or winglets 3 was a row of...devices are vortex generators, fences, high lift flaps, and winglets . Active flow control injects the boundary layer with energy from small jets of
Bench Test Evaluation of Adaptive Servoventilation Devices for Sleep Apnea Treatment
Zhu, Kaixian; Kharboutly, Haissam; Ma, Jianting; Bouzit, Mourad; Escourrou, Pierre
2013-01-01
Rationale: Adaptive servoventilation devices are marketed to overcome sleep disordered breathing with apneas and hypopneas of both central and obstructive mechanisms often experienced by patients with chronic heart failure. The clinical efficacy of these devices is still questioned. Study Objectives: This study challenged the detection and treatment capabilities of the three commercially available adaptive servoventilation devices in response to sleep disordered breathing events reproduced on an innovative bench test. Methods: The bench test consisted of a computer-controlled piston and a Starling resistor. The three devices were subjected to a flow sequence composed of central and obstructive apneas and hypopneas including Cheyne-Stokes respiration derived from a patient. The responses of the devices were separately evaluated with the maximum and the clinical settings (titrated expiratory positive airway pressure), and the detected events were compared to the bench-scored values. Results: The three devices responded similarly to central events, by increasing pressure support to raise airflow. All central apneas were eliminated, whereas hypopneas remained. The three devices responded differently to the obstructive events with the maximum settings. These obstructive events could be normalized with clinical settings. The residual events of all the devices were scored lower than bench test values with the maximum settings, but were in agreement with the clinical settings. However, their mechanisms were misclassified. Conclusion: The tested devices reacted as expected to the disordered breathing events, but not sufficiently to normalize the breathing flow. The device-scored results should be used with caution to judge efficacy, as their validity depends upon the initial settings. Citation: Zhu K; Kharboutly H; Ma J; Bouzit M; Escourrou P. Bench test evaluation of adaptive servoventilation devices for sleep apnea treatment. J Clin Sleep Med 2013;9(9):861-871. PMID:23997698
Portable devices and mobile instruments for infectious diseases point-of-care testing.
Bissonnette, Luc; Bergeron, Michel G
2017-05-01
Rapidity, simplicity, and portability are highly desirable characteristics of tests and devices designed for performing diagnostics at the point of care (POC), either near patients managed in healthcare facilities or to offer bioanalytical alternatives in external settings. By reducing the turnaround time of the diagnostic cycle, POC diagnostics can reduce the dissemination, morbidity, and mortality of infectious diseases and provide tools to control the global threat of antimicrobial resistance. Areas covered: A literature search of PubMed and Google Scholar, and extensive mining of specialized publications, Internet resources, and manufacturers' websites have been used to organize and write this overview of the challenges and requirements associated with the development of portable sample-to-answer diagnostics, and showcase relevant examples of handheld devices, portable instruments, and less mobile systems which may or could be operated at POC. Expert commentary: Rapid (<1 h) diagnostics can contribute to control infectious diseases and antimicrobial resistant pathogens. Portable devices or instruments enabling sample-to-answer bioanalysis can provide rapid, robust, and reproducible testing at the POC or close from it. Beyond testing, to realize some promises of personalized/precision medicine, it will be critical to connect instruments to healthcare data management systems, to efficiently link decentralized testing results to the electronic medical record of patients.
40 CFR 63.2460 - What requirements must I meet for batch process vents?
Code of Federal Regulations, 2010 CFR
2010-07-01
.... (ii) When you conduct a performance test or design evaluation for a non-flare control device used to... paragraphs (c)(9)(ii)(A) through (D) of this section. The design evaluation option for small control devices...) of this section. (b) Group status. If a process has batch process vents, as defined in § 63.2550, you...
40 CFR 63.2460 - What requirements must I meet for batch process vents?
Code of Federal Regulations, 2011 CFR
2011-07-01
.... (ii) When you conduct a performance test or design evaluation for a non-flare control device used to... paragraphs (c)(9)(ii)(A) through (D) of this section. The design evaluation option for small control devices...) of this section. (b) Group status. If a process has batch process vents, as defined in § 63.2550, you...
40 CFR 63.2460 - What requirements must I meet for batch process vents?
Code of Federal Regulations, 2014 CFR
2014-07-01
.... (ii) When you conduct a performance test or design evaluation for a non-flare control device used to... paragraphs (c)(9)(ii)(A) through (D) of this section. The design evaluation option for small control devices... (c) of this section. (b) Group status. If a process has batch process vents, as defined in § 63.2550...
40 CFR 63.2460 - What requirements must I meet for batch process vents?
Code of Federal Regulations, 2012 CFR
2012-07-01
.... (ii) When you conduct a performance test or design evaluation for a non-flare control device used to... paragraphs (c)(9)(ii)(A) through (D) of this section. The design evaluation option for small control devices... (c) of this section. (b) Group status. If a process has batch process vents, as defined in § 63.2550...
40 CFR 63.2460 - What requirements must I meet for batch process vents?
Code of Federal Regulations, 2013 CFR
2013-07-01
.... (ii) When you conduct a performance test or design evaluation for a non-flare control device used to... paragraphs (c)(9)(ii)(A) through (D) of this section. The design evaluation option for small control devices... (c) of this section. (b) Group status. If a process has batch process vents, as defined in § 63.2550...
Testing of Safety-Critical Software Embedded in an Artificial Heart
NASA Astrophysics Data System (ADS)
Cha, Sungdeok; Jeong, Sehun; Yoo, Junbeom; Kim, Young-Gab
Software is being used more frequently to control medical devices such as artificial heart or robotic surgery system. While much of software safety issues in such systems are similar to other safety-critical systems (e.g., nuclear power plants), domain-specific properties may warrant development of customized techniques to demonstrate fitness of the system on patients. In this paper, we report results of a preliminary analysis done on software controlling a Hybrid Ventricular Assist Device (H-VAD) developed by Korea Artificial Organ Centre (KAOC). It is a state-of-the-art artificial heart which completed animal testing phase. We performed software testing in in-vitro experiments and animal experiments. An abnormal behaviour, never detected during extensive in-vitro analysis and animal testing, was found.
Passive and Active Control of Space Structures (PACOSS)
NASA Astrophysics Data System (ADS)
Morosow, G.; Harcrow, H.; Rogers, L.
1985-04-01
Passive and Active Control of Space Structures (PACOSS) is a five-year program designed to investigate highly damped structures in conjunction with active control systems, and in particular to develop technology that integrates passive damping and active control to achieve precise pointing control. Major areas of research include metal matrix composites; viscoelastic materials; damping devices; dynamic test article design, fabrication and testing; and active damping.
ELOPTA: a novel microcontroller-based operant device.
Hoffman, Adam M; Song, Jianjian; Tuttle, Elaina M
2007-11-01
Operant devices have been used for many years in animal behavior research, yet such devices a regenerally highly specialized and quite expensive. Although commercial models are somewhat adaptable and resilient, they are also extremely expensive and are controlled by difficult to learn proprietary software. As an alternative to commercial devices, we have designed and produced a fully functional, programmable operant device, using a PICmicro microcontroller (Microchip Technology, Inc.). The electronic operant testing apparatus (ELOPTA) is designed to deliver food when a study animal, in this case a bird, successfully depresses the correct sequence of illuminated keys. The device logs each keypress and can detect and log whenever a test animal i spositioned at the device. Data can be easily transferred to a computer and imported into any statistical analysis software. At about 3% the cost of a commercial device, ELOPTA will advance behavioral sciences, including behavioral ecology, animal learning and cognition, and ethology.
Electrorheological Fluid Based Force Feedback Device
NASA Technical Reports Server (NTRS)
Pfeiffer, Charles; Bar-Cohen, Yoseph; Mavroidis, Constantinos; Dolgin, Benjamin
1999-01-01
Parallel to the efforts to develop fully autonomous robots, it is increasingly being realized that there are applications where it is essential to have a fully controlled robot and "feel" its operating conditions, i.e. telepresence. This trend is a result of the increasing efforts to address tasks where humans can perform significantly better but, due to associated hazards, distance, physical limitations and other causes, only robots can be employed to perform these tasks. Such robots need to be assisted by a human that remotely controls the operation. To address the goal of operating robots as human surrogates, the authors launched a study of mechanisms that provide mechanical feedback. For this purpose, electrorheological fluids (ERF) are being investigated for the potential application as miniature haptic devices. This family of electroactive fluids has the property of changing the viscosity during electrical stimulation. Consequently, ERF can be used to produce force feedback haptic devices for tele-operated control of medical and space robotic systems. Forces applied at the robot end-effector due to a compliant environment are reflected to the user using an ERF device where a change in the system viscosity will occur proportionally to the transmitted force. Analytical model and control algorithms are being developed taking into account the non-linearities of these type of devices. This paper will describe the concept and the developed mechanism of ERF based force feedback. The test process and the physical properties of this device will be described and the results of preliminary tests will be presented.
DOT National Transportation Integrated Search
2012-06-01
The tremendous growth in the amount of available weather and road condition informationincluding devices that gather weather information, models and forecasting tools for predicting weather conditions, and electronic devices used by travelersha...
Strategies for Radiation Hardness Testing of Power Semiconductor Devices
NASA Technical Reports Server (NTRS)
Soltis, James V. (Technical Monitor); Patton, Martin O.; Harris, Richard D.; Rohal, Robert G.; Blue, Thomas E.; Kauffman, Andrew C.; Frasca, Albert J.
2005-01-01
Plans on the drawing board for future space missions call for much larger power systems than have been flown in the past. These systems would employ much higher voltages and currents to enable more powerful electric propulsion engines and other improvements on what will also be much larger spacecraft. Long term human outposts on the moon and planets would also require high voltage, high current and long life power sources. Only hundreds of watts are produced and controlled on a typical robotic exploration spacecraft today. Megawatt systems are required for tomorrow. Semiconductor devices used to control and convert electrical energy in large space power systems will be exposed to electromagnetic and particle radiation of many types, depending on the trajectory and duration of the mission and on the power source. It is necessary to understand the often very different effects of the radiations on the control and conversion systems. Power semiconductor test strategies that we have developed and employed will be presented, along with selected results. The early results that we have obtained in testing large power semiconductor devices give a good indication of the degradation in electrical performance that can be expected in response to a given dose. We are also able to highlight differences in radiation hardness that may be device or material specific.
TEST QA PLAN FOR THE VERIFICATION TESTING OF BAGHOUSE FILTRATION PRODUCTS
Baghouses and their accompanying filter media are a leading particulate control technique for industrial sources. Increasingly emphasis on higher removal efficiencies has helped the baghouse to be even more competitive when compared to other control devices. At present there is n...
UFC advisor: An AI-based system for the automatic test environment
NASA Technical Reports Server (NTRS)
Lincoln, David T.; Fink, Pamela K.
1990-01-01
The Air Logistics Command within the Air Force is responsible for maintaining a wide variety of aircraft fleets and weapon systems. To maintain these fleets and systems requires specialized test equipment that provides data concerning the behavior of a particular device. The test equipment is used to 'poke and prod' the device to determine its functionality. The data represent voltages, pressures, torques, temperatures, etc. and are called testpoints. These testpoints can be defined numerically as being in or out of limits/tolerance. Some test equipment is termed 'automatic' because it is computer-controlled. Due to the fact that effective maintenance in the test arena requires a significant amount of expertise, it is an ideal area for the application of knowledge-based system technology. Such a system would take testpoint data, identify values out-of-limits, and determine potential underlying problems based on what is out-of-limits and how far. This paper discusses the application of this technology to a device called the Unified Fuel Control (UFC) which is maintained in this manner.
NASA Technical Reports Server (NTRS)
Weick, Fred E; Noyes, Richard W
1933-01-01
Three model wings, two with typical slotted ailerons and one with typical frise ailerons, have been tested as part of a general investigation on lateral control devices with particular reference to their effectiveness at high angles of attack, in the 7 by 10 foot wind tunnel of the National Advisory Committee for Aeronautics. Force tests, free-autorotation tests, and forced-rotation tests were made which show the effect of the various ailerons on the general performance of the wing, on the lateral controllability, and on the lateral stability, in general, rolling control at 20 degree angle of attack to plain ailerons of the same size. The adverse yawing moments obtained with the slotted and frise ailerons were, in most cases, slightly smaller than those obtained with plain ailerons of the same size and deflection. However, this improvement was small as compared to the improvement obtainable by the use of suitable differential movements with any of the ailerons, including the plain.
Drag Reduction Devices for Aircraft (Latest Citations from the Aerospace Database)
NASA Technical Reports Server (NTRS)
1996-01-01
The bibliography contains citations concerning the modeling, application, testing, and development of drag reduction devices for aircraft. Slots, flaps, fences, large-eddy breakup (LEBU) devices, vortex generators and turbines, Helmholtz resonators, and winglets are among the devices discussed. Contour shaping to ensure laminar flow, control boundary layer transition, or minimize turbulence is also covered. Applications include the wings, nacelles, fuselage, empennage, and externals of aircraft designed for high-lift, subsonic, or supersonic operation. The design, testing, and development of directional grooves, commonly called riblets, are covered in a separate bibliography.(Contains 50-250 citations and includes a subject term index and title list.)
NASA Astrophysics Data System (ADS)
Du, H.; Wang, Y. P.; Yuan, X. H.; Deng, Y. D.; Su, C. Q.
2016-03-01
To improve the riding comfort and rational utilization of the electrical energy captured by an automotive thermoelectric generator (ATEG), a temperature-controlled car seat was constructed to adjust the temperature of the car seat surface. Powered by the ATEG and the battery, the seat-embedded air conditioner can improve the riding comfort using a thermoelectric device to adjust the surface temperature of the seat, with an air duct to regulate the cold side and hot side of the thermoelectric device. The performance of the thermoelectric cooler (TEC) and theoretical analysis on the optimum state of the TEC device are put forward. To verify the rationality of the air duct design and to ensure sufficient air supply, the velocity field of the air duct system was obtained by means of the finite element method. To validate the reliability of the numerical simulation, the air velocity around the thermoelectric device was measured by a wind speed transmitter. The performance of the temperature-controlled car seat has been validated and is in good agreement with bench tests and real vehicle tests.
A novel reflex cough testing device.
Fujiwara, Kazunori; Kawamoto, Katsuyuki; Shimizu, Yoko; Fukuhara, Takahiro; Koyama, Satoshi; Kataoka, Hideyuki; Kitano, Hiroya; Takeuchi, Hiromi
2017-01-18
The reflex cough test is useful for detecting silent aspiration, a risk factor for aspiration pneumonia. However, assessing the risk of aspiration pneumonia requires measuring not only the cough reflex but also cough strength. Currently, no reflex cough testing device is available that can directly measure reflex cough strength. We therefore developed a new testing device that can easily and simultaneously measure cough strength and the time until the cough reflex, and verified whether screening with this new instrument is feasible for evaluating the risk of aspiration pneumonia. This device consists of a special pipe with a double lumen, a nebulizer, and an electronic spirometer. We used a solution of prescription-grade L-tartaric acid to initiate the cough reflex. The solution was inhaled through a mouthpiece as a microaerosol produced by an ultrasonic nebulizer. The peak cough flow (PCF) of the induced cough was measured with the spirometer. The 70 patients who participated in this study comprised 49 patients without a history of pneumonia (group A), 21 patients with a history of pneumonia (group B), and 10 healthy volunteers (control group). With the novel device, PCF and time until cough reflex could be measured without adverse effects. The PCF values were 118.3 ± 64.0 L/min, 47.7 ± 38.5 L/min, and 254.9 ± 83.8 L/min in group A, group B, and the control group, respectively. The PCF of group B was significantly lower than that of group A and the control group (p < 0.0001), while that of group B was significantly lower than that of the control group (p < 0.0001). The time until the cough reflex was 4.2 ± 5.9 s, 7.0 ± 7.0 s, and 1 s in group A, group B, and the control group, respectively. This duration was significantly longer for groups A and B than for the control group (A: p < 0.001, B: p < 0.001), but there was no significant difference between groups A and B (p = 0.0907). Our newly developed device can easily and simultaneously measure the time until the cough reflex and the strength of involuntary coughs for assessment of patients at risk of aspiration pneumonia.
Net current control device. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fugate, D.; Cooper, J.H.
1998-11-01
Net currents generally result in elevated magnetic fields because the alternate paths are distant from the circuit conductors. Investigations have shown that one of the primary sources of power frequency magnetic fields in residential buildings is currents that return to their source via paths other than the neutral conductors. As part of EPRI`s Magnetic Field Shielding Project, ferromagnetic devices, called net current control (NCC) devices, were developed and tested for use in reducing net currents on electric power cables and the resulting magnetic fields. Applied to a residential service drop, an NCC device reduces net current by forcing current offmore » local non-utility ground paths, and back onto the neutral conductor. Circuit models and basic design equations for the NCC concept were developed, and proof-of-principles tests were carried out on an actual residence with cooperation from the local utility. After proving the basic concepts, three prototype NCC devices were built and tested on a simulated neighborhood power system. Additional prototypes were built for testing by interested EPRI utility members. Results have shown that the NCC prototypes installed on residential service drops reduce net currents to milliampere levels with compromising the safety of the ground system. Although the focus was on application to residential service cables, the NCC concept is applicable to single-phase and three-phase distribution systems as well.« less
Bienek, Diane R; Charlton, David G
2012-05-01
Being able to test for the presence of blood pathogens at forward locations could reduce morbidity and mortality in the field. Rapid, user-friendly blood typing kits for detecting Human Immunodeficiency Virus (HIV), Hepatitis C Virus (HCV), and Hepatitis B Virus (HBV) were evaluated to determine their accuracy after storage at various temperatures/humidities. Rates of positive tests of control groups, experimental groups, and industry standards were compared (Fisher's exact chi2, p < or = 0.05). Compared to the control group, 2 of 10 HIV detection devices were adversely affected by exposure to high temperature/high humidity or high temperature/low humidity. With one exception, none of the environmentally exposed HCV or HBV detection devices exhibited significant differences compared to those stored under control conditions. For HIV, HCV, and HBV devices, there were differences compared to the industry standard. Collectively, this evaluation of pathogen detection kits revealed that diagnostic performance varies among products and storage conditions, and that the tested products cannot be considered to be approved for use to screen blood, plasma, cell, or tissue donors.
Control of unsteady separated flow associated with the dynamic stall of airfoils
NASA Technical Reports Server (NTRS)
Wilder, Michael C.
1992-01-01
The two principal objectives of this research were to achieve an improved understanding of the mechanisms involved in the onset and development of dynamic stall under compressible flow conditions, and to investigate the feasibility of employing adaptive airfoil geometry as an active flow control device in the dynamic stall engine. Presented here are the results of a quantitative (PDI) study of the compressibility effects on dynamic stall over the transiently pitching airfoil, as well as a discussion of a preliminary technique developed to measure the deformation produced by the adaptive geometry control device, and bench test results obtained using an airfoil equipped with the device.
40 CFR 63.5722 - How do I use the performance test data to demonstrate initial compliance?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 12 2011-07-01 2009-07-01 true How do I use the performance test data... Manufacturing Demonstrating Compliance for Open Molding Operations Controlled by Add-on Control Devices § 63.5722 How do I use the performance test data to demonstrate initial compliance? Demonstrate initial...
40 CFR 63.5722 - How do I use the performance test data to demonstrate initial compliance?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 12 2010-07-01 2010-07-01 true How do I use the performance test data... Manufacturing Demonstrating Compliance for Open Molding Operations Controlled by Add-on Control Devices § 63.5722 How do I use the performance test data to demonstrate initial compliance? Demonstrate initial...
40 CFR 63.5722 - How do I use the performance test data to demonstrate initial compliance?
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 13 2014-07-01 2014-07-01 false How do I use the performance test data... Boat Manufacturing Demonstrating Compliance for Open Molding Operations Controlled by Add-on Control Devices § 63.5722 How do I use the performance test data to demonstrate initial compliance? Demonstrate...
40 CFR 63.5722 - How do I use the performance test data to demonstrate initial compliance?
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 13 2013-07-01 2012-07-01 true How do I use the performance test data... Boat Manufacturing Demonstrating Compliance for Open Molding Operations Controlled by Add-on Control Devices § 63.5722 How do I use the performance test data to demonstrate initial compliance? Demonstrate...
40 CFR 63.5722 - How do I use the performance test data to demonstrate initial compliance?
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 13 2012-07-01 2012-07-01 false How do I use the performance test data... Boat Manufacturing Demonstrating Compliance for Open Molding Operations Controlled by Add-on Control Devices § 63.5722 How do I use the performance test data to demonstrate initial compliance? Demonstrate...
Pavlaković, G; Züchner, K; Zapf, A; Bachmann, C G; Graf, B M; Crozier, T A; Pavlaković, H
2009-08-01
Various factors can influence thermal perception threshold measurements and contribute significantly to unwanted variability of the tests. To minimize this variability, testing should be performed under strictly controlled conditions. Identifying the factors that increase the variability and eliminating their influence should increase reliability and reproducibility. Currently available thermotesting devices use a water-cooling system that generates a continuous noise of approximately 60 dB. In order to analyze whether this noise could influence the thermal threshold measurements we compared the thresholds obtained with a silent thermotesting device to those obtained with a commercially available device. The subjects were tested with one randomly chosen device on 1 day and with the other device 7 days later. At each session, heat, heat pain, cold, and cold pain thresholds were determined with three measurements. Bland-Altman analysis was used to assess agreement in measurements obtained with different devices and it was shown that the intersubject variability of the thresholds obtained with the two devices was comparable for all four thresholds tested. In contrast, the intrasubject variability of the thresholds for heat, heat pain, and cold pain detection was significantly lower with the silent device. Our results show that thermal sensory thresholds measured with the two devices are comparable. However, our data suggest that, for studies with repeated measurements on the same subjects, a silent thermotesting device may allow detection of smaller differences in the treatment effects and/or may permit the use of a smaller number of tested subjects. Muscle Nerve 40: 257-263, 2009.
Detection of radio-frequency modulated optical signals by two and three terminal microwave devices
NASA Technical Reports Server (NTRS)
Bhasin, K. B.; Simons, R. N.; Wojtczuk, S.
1987-01-01
An interdigitated photoconductor (two terminal device) on GaAlAs/GaAs heterostructure was fabricated and tested by an electro-optical sampling technique. Further, the photoresponse of GaAlAs/GaAs HEMT (three terminal device) was obtained by illuminating the device with an optical signal modulated up to 8 GHz. Gain-bandwidth product, response time, and noise properties of photoconductor and HEMT devices were obtained. Monolithic integration of these photodetectors with GaAs microwave devices for optically controlled phased array antenna applications is discussed.
Reliability Testing of NASA Piezocomposite Actuators
NASA Technical Reports Server (NTRS)
Wilkie, W.; High, J.; Bockman, J.
2002-01-01
NASA Langley Research Center has developed a low-cost piezocomposite actuator which has application for controlling vibrations in large inflatable smart space structures, space telescopes, and high performance aircraft. Tests show the NASA piezocomposite device is capable of producing large, directional, in-plane strains on the order of 2000 parts-per-million peak-to-peak, with no reduction in free-strain performance to 100 million electrical cycles. This paper describes methods, measurements, and preliminary results from our reliability evaluation of the device under externally applied mechanical loads and at various operational temperatures. Tests performed to date show no net reductions in actuation amplitude while the device was moderately loaded through 10 million electrical cycles. Tests were performed at both room temperature and at the maximum operational temperature of the epoxy resin system used in manufacture of the device. Initial indications are that actuator reliability is excellent, with no actuator failures or large net reduction in actuator performance.
Muzslay, M; Yui, S; Ali, S; Wilson, A P R
2018-04-09
Mobile phones and tablet computers may be contaminated with microorganisms and become a potential reservoir for cross-transmission of pathogens between healthcare workers and patients. There is no generally accepted guidance how to reduce contamination on mobile devices in healthcare settings. Our aim was to determine the efficacy of the Codonics D6000™ UV-C disinfection device. Daily disinfection reduced contamination on screens and on protective cases (test) significantly, but not all cases (control) could be decontaminated. The median aerobic colony count on the control and the test cases was 52 (IQR 33-89) cfu/25cm 2 and 22 (IQR 10.5-41) cfu/25cm 2 respectively before disinfection. Copyright © 2018. Published by Elsevier Ltd.
40 CFR Table 4 to Subpart Zzzz of... - Requirements for Performance Tests
Code of Federal Regulations, 2010 CFR
2010-07-01
... and outlet of the control device; and (1) Portable CO and O2 analyzer. (a) Using ASTM D6522-00 (2005... control device (1) Portable CO and O2 analyzer. (a) Using ASTM D6522-00 (2005) a,b (incorporated by..., appendix A, or ASTM Method D6522-00 (2005) (a) Measurements to determine O2 concentration must be made at...
Single event effects in pulse width modulation controllers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Penzin, S.H.; Crain, W.R.; Crawford, K.B.
1996-12-01
SEE testing was performed on pulse width modulation (PWM) controllers which are commonly used in switching mode power supply systems. The devices are designed using both Set-Reset (SR) flip-flops and Toggle (T) flip-flops which are vulnerable to single event upset (SEU) in a radiation environment. Depending on the implementation of the different devices the effect can be significant in spaceflight hardware.
Valdez-González, Leticia A; Méndez-Padrón, Araceli; Gómez-Díaz, Rita A; Valladares-Salgado, Adán; Sánchez-Becerra, Martha Catalina; Mondragón-González, Rafael; Hernández-Rubí, Jaime; González-Hermosillo, Arturo; Cruz, Miguel; Borja, Víctor; Wacher, Niels H
The albumin-creatinine ratio is considered an indicator of microalbuminuria, precursor to chronic kidney disease, while HbA1c is used to measure glycemic control. Given the prevalence of diabetes-related nephropathy, spot testing of albumin has long been recommended as a preventative measure, for the timely detection of microalbuminuria. However, many countries do not have this testing available in primary care, and sometimes not even in second- and third-level care. The objective of this study was to compare agreement of the microalbuminuria and HbA1c results obtained in the laboratory with 'gold standard' techniques, with those obtained on site with a 'Point of Care' DCA Vantage™ device by Siemens. Results for the albumin-creatinine ratio and HbA1c from the Siemens DCA Vantage™ point of care device were compared with those from standard laboratory tests in 25 family medicine units in Mexico City and Toluca, State of Mexico, in patients diagnosed with type-2 diabetes. Agreement between the albumin values of the 2 tests was 0.745 (CI 95% 0.655-0.812). Agreement between the two measurement techniques for HbA1c was 0.970 (CI 95% 0.966-0.973). The results obtained were sufficiently comparative (R i = 0.74 for albumin-creatinine ratio and R i = 0.97 for HbA1c) to justify the use of the point of care device. Given the high agreement between the point of care device and laboratory tests, this device could be used to identify chronic kidney disease and glycemic control for more adequate treatment in patients with diabetes, especially in remote areas.
Open core control software for surgical robots
Kozuka, Hiroaki; Kim, Hyung Wook; Takesue, Naoyuki; Vladimirov, B.; Sakaguchi, Masamichi; Tokuda, Junichi; Hata, Nobuhiko; Chinzei, Kiyoyuki; Fujimoto, Hideo
2010-01-01
Object In these days, patients and doctors in operation room are surrounded by many medical devices as resulting from recent advancement of medical technology. However, these cutting-edge medical devices are working independently and not collaborating with each other, even though the collaborations between these devices such as navigation systems and medical imaging devices are becoming very important for accomplishing complex surgical tasks (such as a tumor removal procedure while checking the tumor location in neurosurgery). On the other hand, several surgical robots have been commercialized, and are becoming common. However, these surgical robots are not open for collaborations with external medical devices in these days. A cutting-edge “intelligent surgical robot” will be possible in collaborating with surgical robots, various kinds of sensors, navigation system and so on. On the other hand, most of the academic software developments for surgical robots are “home-made” in their research institutions and not open to the public. Therefore, open source control software for surgical robots can be beneficial in this field. From these perspectives, we developed Open Core Control software for surgical robots to overcome these challenges. Materials and methods In general, control softwares have hardware dependencies based on actuators, sensors and various kinds of internal devices. Therefore, these control softwares cannot be used on different types of robots without modifications. However, the structure of the Open Core Control software can be reused for various types of robots by abstracting hardware dependent parts. In addition, network connectivity is crucial for collaboration between advanced medical devices. The OpenIGTLink is adopted in Interface class which plays a role to communicate with external medical devices. At the same time, it is essential to maintain the stable operation within the asynchronous data transactions through network. In the Open Core Control software, several techniques for this purpose were introduced. Virtual fixture is well known technique as a “force guide” for supporting operators to perform precise manipulation by using a master–slave robot. The virtual fixture for precise and safety surgery was implemented on the system to demonstrate an idea of high-level collaboration between a surgical robot and a navigation system. The extension of virtual fixture is not a part of the Open Core Control system, however, the function such as virtual fixture cannot be realized without a tight collaboration between cutting-edge medical devices. By using the virtual fixture, operators can pre-define an accessible area on the navigation system, and the area information can be transferred to the robot. In this manner, the surgical console generates the reflection force when the operator tries to get out from the pre-defined accessible area during surgery. Results The Open Core Control software was implemented on a surgical master–slave robot and stable operation was observed in a motion test. The tip of the surgical robot was displayed on a navigation system by connecting the surgical robot with a 3D position sensor through the OpenIGTLink. The accessible area was pre-defined before the operation, and the virtual fixture was displayed as a “force guide” on the surgical console. In addition, the system showed stable performance in a duration test with network disturbance. Conclusion In this paper, a design of the Open Core Control software for surgical robots and the implementation of virtual fixture were described. The Open Core Control software was implemented on a surgical robot system and showed stable performance in high-level collaboration works. The Open Core Control software is developed to be a widely used platform of surgical robots. Safety issues are essential for control software of these complex medical devices. It is important to follow the global specifications such as a FDA requirement “General Principles of Software Validation” or IEC62304. For following these regulations, it is important to develop a self-test environment. Therefore, a test environment is now under development to test various interference in operation room such as a noise of electric knife by considering safety and test environment regulations such as ISO13849 and IEC60508. The Open Core Control software is currently being developed software in open-source manner and available on the Internet. A communization of software interface is becoming a major trend in this field. Based on this perspective, the Open Core Control software can be expected to bring contributions in this field. PMID:20033506
Methods of Measurement for Semiconductor Materials, Process Control, and Devices
NASA Technical Reports Server (NTRS)
Bullis, W. M. (Editor)
1973-01-01
The development of methods of measurement for semiconductor materials, process control, and devices is reported. Significant accomplishments include: (1) Completion of an initial identification of the more important problems in process control for integrated circuit fabrication and assembly; (2) preparations for making silicon bulk resistivity wafer standards available to the industry; and (3) establishment of the relationship between carrier mobility and impurity density in silicon. Work is continuing on measurement of resistivity of semiconductor crystals; characterization of generation-recombination-trapping centers, including gold, in silicon; evaluation of wire bonds and die attachment; study of scanning electron microscopy for wafer inspection and test; measurement of thermal properties of semiconductor devices; determination of S-parameters and delay time in junction devices; and characterization of noise and conversion loss of microwave detector diodes.
Tang, Ruihua; Yang, Hui; Gong, Yan; You, MinLi; Liu, Zhi; Choi, Jane Ru; Wen, Ting; Qu, Zhiguo; Mei, Qibing; Xu, Feng
2017-03-29
Nucleic acid testing (NAT) has been widely used for disease diagnosis, food safety control and environmental monitoring. At present, NAT mainly involves nucleic acid extraction, amplification and detection steps that heavily rely on large equipment and skilled workers, making the test expensive, time-consuming, and thus less suitable for point-of-care (POC) applications. With advances in paper-based microfluidic technologies, various integrated paper-based devices have recently been developed for NAT, which however require off-chip reagent storage, complex operation steps and equipment-dependent nucleic acid amplification, restricting their use for POC testing. To overcome these challenges, we demonstrate a fully disposable and integrated paper-based sample-in-answer-out device for NAT by integrating nucleic acid extraction, helicase-dependent isothermal amplification and lateral flow assay detection into one paper device. This simple device allows on-chip dried reagent storage and equipment-free nucleic acid amplification with simple operation steps, which could be performed by untrained users in remote settings. The proposed device consists of a sponge-based reservoir and a paper-based valve for nucleic acid extraction, an integrated battery, a PTC ultrathin heater, temperature control switch and on-chip dried enzyme mix storage for isothermal amplification, and a lateral flow test strip for naked-eye detection. It can sensitively detect Salmonella typhimurium, as a model target, with a detection limit of as low as 10 2 CFU ml -1 in wastewater and egg, and 10 3 CFU ml -1 in milk and juice in about an hour. This fully disposable and integrated paper-based device has great potential for future POC applications in resource-limited settings.
The Software Element of the NASA Portable Electronic Device Radiated Emissions Investigation
NASA Technical Reports Server (NTRS)
Koppen, Sandra V.; Williams, Reuben A. (Technical Monitor)
2002-01-01
NASA Langley Research Center's (LaRC) High Intensity Radiated Fields Laboratory (HIRF Lab) recently conducted a series of electromagnetic radiated emissions tests under a cooperative agreement with Delta Airlines and an interagency agreement with the FAA. The frequency spectrum environment at a commercial airport was measured on location. The environment survey provides a comprehensive picture of the complex nature of the electromagnetic environment present in those areas outside the aircraft. In addition, radiated emissions tests were conducted on portable electronic devices (PEDs) that may be brought onboard aircraft. These tests were performed in both semi-anechoic and reverberation chambers located in the HIRF Lab. The PEDs included cell phones, laptop computers, electronic toys, and family radio systems. The data generated during the tests are intended to support the research on the effect of radiated emissions from wireless devices on aircraft systems. Both tests systems relied on customized control and data reduction software to provide test and instrument control, data acquisition, a user interface, real time data reduction, and data analysis. The software executed on PC's running MS Windows 98 and 2000, and used Agilent Pro Visual Engineering Environment (VEE) development software, Common Object Model (COM) technology, and MS Excel.
Wulf, G; Toole, T
1999-09-01
This study examines the effects of a self-controlled use of physical assistance devices on learning a complex motor skill (i.e., producing slalom-type movements on a ski simulator). Physical assistance was provided by ski poles. One group of learners (self-control) was provided with the poles whenever they requested them, whereas another (yoked) group had no influence on the pole/no-pole schedule. While there were no group differences during the practice phase (Days 1 and 2), clear group differences emerged in the retention test without poles (Day 3). The self-control group produced significantly larger amplitudes than the yoked group. These results extend previous findings by showing learning advantages of the self-controlled use of physical assistance devices in complex motor skill learning.
Separation control by vortex generator devices in a transonic channel flow
NASA Astrophysics Data System (ADS)
Bur, Reynald; Coponet, Didier; Carpels, Yves
2009-12-01
An experimental study was conducted in a transonic channel to control by mechanical vortex generator devices the strong interaction between a shock wave and a separated turbulent boundary layer. Control devices—co-rotating and counter-rotating vane-type vortex generators—were implemented upstream of the shock foot region and tested both on a steady shock wave and on a forced shock oscillation configurations. The spanwise spacing of vortex generator devices along the channel appeared to be an important parameter to control the flow separation region. When the distance between each device is decreased, the vortices merging is more efficient to reduce the separation. Their placement upstream of the shock wave is determinant to ensure that vortices have mixed momentum all spanwise long before they reach the separation line, so as to avoid separation cells. Then, vortex generators slightly reduced the amplitude of the forced shock wave oscillation by delaying the upstream displacement of the leading shock.
NASA Astrophysics Data System (ADS)
Stadler, Philipp; Farnleitner, Andreas H.; Zessner, Matthias
2016-04-01
This presentation describes in-depth how a low cost micro-computer was used for substantial improvement of established measuring systems due to the construction and implementation of a purposeful complementary device for on-site sample pretreatment. A fully automated on-site device was developed and field-tested, that enables water sampling with simultaneous filtration as well as effective cleaning procedure of the devicés components. The described auto-sampler is controlled by a low-cost one-board computer and designed for sample pre-treatment, with minimal sample alteration, to meet requirements of on-site measurement devices that cannot handle coarse suspended solids within the measurement procedure or -cycle. The automated sample pretreatment was tested for over one year for rapid and on-site enzymatic activity (beta-D-glucuronidase, GLUC) determination in sediment laden stream water. The formerly used proprietary sampling set-up was assumed to lead to a significant damping of the measurement signal due to its susceptibility to clogging, debris- and bio film accumulation. Results show that the installation of the developed apparatus considerably enhanced error-free running time of connected measurement devices and increased the measurement accuracy to an up-to-now unmatched quality.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bouchier, F.; Ahrens, J.S.; Wells, G.
One thing that all access control applications have in common is the need to identify those individuals authorized to gain access to an area. Traditionally, the identification is based on something that person possesses, such as a key or badge, or something they know, such as a PIN or password. Biometric identifiers make their decisions based on the physiological or behavioral characteristics of individuals. The potential of biometrics devices to positively identify individuals has made them attractive for use in access control and computer security applications. However, no systems perform perfectly, so it is important to understand what a biometricmore » device`s performance is under real world conditions before deciding to implement one in an access control system. This paper will describe the evaluation of a prototype biometric identifier provided by IriScan Incorporated. This identifier was developed to recognize individual human beings based on the distinctive visual characteristics of the irises of their eyes. The main goal of the evaluation was to determine whether the system has potential as an access control device within the Department of Energy (DOE). The primary interest was an estimate of the accuracy of the system in terms of false accept and false reject rates. Data was also collected to estimate throughput time and user acceptability. The performance of the system during the test will be discussed. Lessons learned during the test which may aid in further testing and simplify implementation of a production system will also be discussed.« less
NASA Astrophysics Data System (ADS)
Ferrara, T.; Howard, T. M.
2016-12-01
Studies attempting to reconcile facility level emission estimates of sources at oil and gas facilities with basin wide methane flux measurements have had limited success. Pneumatic devices are commonly used at oil and gas production facilities for process control or liquid pumping. These devices are powered by pressurized natural gas from the well, so they are known methane sources at these sites. Pneumatic devices are estimated to contribute 14% to 25% of the total greenhouse gas emissions (GHG) from production facilities. Measurements of pneumatic devices have shown that malfunctioning or poorly maintained control systems may be emitting significantly more methane than currently estimated. Emission inventories for these facilities use emission factors from EPA that are based on pneumatic device measurements made in the early 1990's. Recent studies of methane emissions from production facilities have attempted to measure emissions from pneumatic devices by several different methods. These methods have had limitations including alteration of the system being measured, the inability to distinguish between leaks and venting during normal operation, or insufficient response time to account of the time based emission events. We have developed a high speed recording high flow sampler that is capable of measuring the transient emissions from pneumatic devices. This sampler is based on the well-established high flow measurement technique used in oil and gas for quantifying component leak rates. In this paper we present the results of extensive laboratory controlled release testing. Additionally, test data from several field studies where this sampler has been used to measure pneumatic device emissions will be presented.
2011-12-30
The Food and Drug Administration (FDA) is amending the regulation classifying ovarian adnexal mass assessment score test systems to restrict these devices so that a prescribed warning statement that addresses a risk identified in the special controls guidance document must be in a black box and must appear in all labeling, advertising, and promotional material. The black box warning mitigates the risk to health associated with off-label use as a screening test, stand-alone diagnostic test, or as a test to determine whether or not to proceed with surgery.
NASA Astrophysics Data System (ADS)
Marra, Kyle; Graham, Brett; Carouso, Samantha; Cox, David
2012-02-01
While the application of local cortical cooling has recently become a focus of neurological research, extended localized deactivation deep within brain structures is still unexplored. Using a wirelessly controlled thermoelectric (Peltier) device and water-based heat sink, we have achieved inactivating temperatures (<20 C) at greater depths (>8 mm) than previously reported. After implanting the device into Long Evans rats' basolateral amygdala (BLA), an inhibitory brain center that controls anxiety and fear, we ran an open field test during which anxiety-driven behavioral tendencies were observed to decrease during cooling, thus confirming the device's effect on behavior. Our device will next be implanted in the rats' temporal association cortex (TeA) and recordings from our signal-tracing multichannel microelectrodes will measure and compare activated and deactivated neuronal activity so as to isolate and study the TeA signals responsible for object recognition. Having already achieved a top performing computational face-recognition system, the lab will utilize this TeA activity data to generalize its computational efforts of face recognition to achieve general object recognition.
Code of Federal Regulations, 2011 CFR
2011-07-01
... secondarily for operation in water. Auxiliary emission control device (AECD) means any element of design that... design which controls or reduces the emission of substances from an engine. Engine, as used in this part... testing, to translation of designs from the test stage to the production stage, or to engine manufacture...
Code of Federal Regulations, 2012 CFR
2012-07-01
... secondarily for operation in water. Auxiliary emission control device (AECD) means any element of design that... design which controls or reduces the emission of substances from an engine. Engine, as used in this part... testing, to translation of designs from the test stage to the production stage, or to engine manufacture...
Code of Federal Regulations, 2014 CFR
2014-07-01
... secondarily for operation in water. Auxiliary emission control device (AECD) means any element of design that... design which controls or reduces the emission of substances from an engine. Engine, as used in this part... testing, to translation of designs from the test stage to the production stage, or to engine manufacture...
DOT National Transportation Integrated Search
2008-04-01
The objective of this study was to develop resilient modulus prediction models for possible application in the quality control/quality assurance (QC/QA) procedures during and after the construction of pavement layers. Field and laboratory testing pro...
Angular-velocity control approach for stance-control orthoses.
Lemaire, Edward D; Goudreau, Louis; Yakimovich, Terris; Kofman, Jonathan
2009-10-01
Currently, stance-control knee orthoses require external control mechanisms to control knee flexion during stance and allow free knee motion during the swing phase of gait. A new angular-velocity control approach that uses a rotary-hydraulic device to resist knee flexion when the knee angular velocity passes a preset threshold is presented. This angular-velocity approach for orthotic stance control is based on the premise that knee-flexion angular velocity during a knee-collapse event, such as a stumble or fall, is greater than that during walking. The new hydraulic knee-flexion control device does not require an external control mechanism to switch from free motion to stance control mode. Functional test results demonstrated that the hydraulic angular-velocity activated knee joint provided free knee motion during walking, engaged upon knee collapse, and supported body weight while the end-user recovered to a safe body position. The joint was tested to 51.6 Nm in single loading tests and passed 200,000 repeated loading cycles with a peak load of 88 Nm per cycle. The hydraulic, angular velocity activation approach has potential to improve safety and security for people with lower extremity weakness or when recovering from joint trauma.
49 CFR 236.576 - Roadway element.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Inspection and Tests; Roadway § 236.576 Roadway element. Roadway...
49 CFR 236.576 - Roadway element.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Inspection and Tests; Roadway § 236.576 Roadway element. Roadway...
Regulatory aspects of noninvasive glucose measurements.
Gutman, Steve; Bernhardt, Patricia; Pinkos, Arleen; Moxey-Mims, Marva; Knott, Thomas; Cooper, Jean
2002-01-01
The Medical Device Amendments of 1976 to the Federal Food, Drug, and Cosmetic Act (the Act) established three regulatory classes for medical devices. Section 513 of the Act specifies three classes based upon the degree of control and Food and Drug Administration (FDA) oversight that is necessary to assure that the various types of devices are safe and effective. High-risk devices are placed into the most regulated device class, Class III. Under Section 515 of the Act, all devices placed in Class III are subject to premarket approval (PMA) requirements. PMA by FDA is the required process of scientific review to ensure the safety and effectiveness of Class III devices. Advisory panel review is required of virtually all original submissions. Manufacturing facilities of devices requiring PMA approval are also subject to preapproval inspection to assure data integrity and compliance with good manufacturing practices. An approved PMA is granted for marketing a particular medical device for a particular intended use. FDA considers noninvasive and minimally invasive glucose devices that are intended to measure, monitor, or predict blood glucose levels in diabetics to be high-risk medical devices. These devices will have a significant potential impact on the medical care of people with diabetes. The technology offers potential improvements in the quality of life, enhanced blood glucose control through increased frequency of testing, or access to testing, in a broader range of patients. However, the technology is not yet well understood, and the information obtained from these devices is often different from the information that has been the traditional base for the management of diabetes. As a result, FDA requires both analytical and clinical studies to support the intended claims for these new devices.
Pneumatic pressure wave generator provides economical, simple testing of pressure transducers
NASA Technical Reports Server (NTRS)
Gaal, A. E.; Weldon, T. P.
1967-01-01
Testing device utilizes the change in pressure about a bias or reference pressure level produced by displacement of a center-driven piston in a closed cylinder. Closely controlled pneumatic pressure waves allow testing under dynamic conditions.
A sampling device with a capped body and detachable handle
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jezek, Gerd-Rainer
1997-12-01
The present invention relates to a device for sampling radioactive waste and more particularly to a device for sampling radioactive waste which prevents contamination of a sampled material and the environment surrounding the sampled material. During vitrification of nuclear wastes, it is necessary to remove contamination from the surfaces of canisters filled with radioactive glass. After removal of contamination, a sampling device is used to test the surface of the canister. The one piece sampling device currently in use creates a potential for spreading contamination during vitrification operations. During operations, the one piece sampling device is transferred into and outmore » of the vitrification cell through a transfer drawer. Inside the cell, a remote control device handles the sampling device to wipe the surface of the canister. A one piece sampling device can be contaminated by the remote control device prior to use. Further, the sample device can also contaminate the transfer drawer producing false readings for radioactive material. The present invention overcomes this problem by enclosing the sampling pad in a cap. The removable handle is reused which reduces the amount of waste material.« less
Code of Federal Regulations, 2012 CFR
2012-07-01
... Pollutants for Stationary Combustion Turbines Pt. 63, Subpt. YYYY, Table 3 Table 3 to Subpart YYYY of Part 63... points AND Method 1 or 1A of 40 CFR part 60, appendix A § 63.7(d)(1)(i) if using an air pollution control device, the sampling site must be located at the outlet of the air pollution control device. c. determine...
33 CFR 159.14 - Application for certification.
Code of Federal Regulations, 2010 CFR
2010-07-01
... description of the manufacturer's production quality control and inspection methods, record keeping systems pertaining to the manufacture of marine sanitation devices, and testing procedures; (2) The design for the... device; and (4) The name and address of the applicant and the manufacturing facility. (c) The...
NASA Technical Reports Server (NTRS)
Price, W. E.; Martin, K. E.; Nichols, D. K.; Gauthier, M. K.; Brown, S. F.
1981-01-01
Steady-state, total-dose radiation test data are provided in graphic format, for use by electronic designers and other personnel using semiconductor devices in a radiation environment. Data are presented by JPL for various NASA space programs on diodes, bipolar transistors, field effect transistors, silicon-controlled rectifiers, and optical devices. A vendor identification code list is included along with semiconductor device electrical parameter symbols and abbreviations.
A three degree of freedom manipulator used for store separation wind tunnel test
NASA Astrophysics Data System (ADS)
Wei, R.; Che, B.-H.; Sun, C.-B.; Zhang, J.; Lu, Y.-Q.
2018-06-01
A three degree of freedom manipulator is presented, which is used for store separation wind tunnel test. It is a kind of mechatronics product, have small volume and large moment of torque. The paper researched the design principle of wind tunnel test equipment, also introduced the transmission principle design, physical design, control system design, drive element selection calculation and verification, dynamics computation and static structural computation of the manipulator. To satisfy the design principle of wind tunnel test equipment, some optimization design are made include optimizes the structure of drive element and cable, fairing configuration, overall dimension so that to make the device more suitable for the wind tunnel test. Some tests are made to verify the parameters of the manipulator. The results show that the device improves the load from 100 Nm to 250 Nm, control accuracy from 0.1°to 0.05°in pitch and yaw, also improves load from 10 Nm to 20 Nm, control accuracy from 0.1°to 0.05°in roll.
WaveSAX device: design optimization through scale modelling and a PTO strategical control system
NASA Astrophysics Data System (ADS)
Peviani, Maximo; Danelli, Andrea; Dadone, Gianluca; Dalmasso, Alberto
2017-04-01
WaveSAX is an innovative OWC (Oscillating Water Column) device for the generation of electricity from wave power, conceived to be installed in coastal marine structures, such as ports and harbours. The device - especially designed for the typical wave climate of Mediterranean Sea - is characterized by two important aspects: flexibility to fit in different structural configurations and replication in a large number of units. A model of the WaveSAX device on a scale 1:5 has been built and tested in the ocean tank at Ecole Centrale de Nantes (France). The study aimed to analyse the behaviour of the device, including two Wells turbine configurations (with three and four blades), with regular and irregular wave conditions in the ocean wave tank. The model and the wave basin were equipped with a series of sensors which allowed to measure the following parameters during the tests: pressure in different points inside the device, the free water surface displacement inside and outside the device, the rotational velocity and the torque at the top of the axis. The tests had the objective to optimize the device design, especially as far as the characteristics of the rotor of the turbine is concern. Although the performance of the WaveSAX has been satisfactory for regular wave conditions, the behaviour of the Wells turbines for irregular wave climate has shown limitations in terms of maintaining the capacity to transform hydraulics energy into mechanical power. To optimize the efficiency of the turbine, an electronical system has been built on the basis of the ocean tank tests. It allows to continuously monitor and command the rotational speed and the torque of the rotor connected with the turbine, and to control in real time the electrical flow of a motor-generator, either absorbing energy as a generator, or providing power to the turbine working as an engine. Two strategies - based on the velocity and the torque control - have been investigate in the electronic test bench simulating four wave conditions previously tested in the ocean tank at the ECN (Nantes, France). The results showed a satisfactory behaviour of the system and allowed to define the optimal velocity and torque conditions to maximize the PTO. REFERENCES 1. M. Peviani, 2015, 'WAVESAX device: conceptual design and perspectives', 8th European Seminar OWEMES 2015, Offshore Wind and other marine renewable Energies in Mediterranean and European Seas, Rome, Italy 2. B. Holmes, K. Nielsen, 2010, Guidelines for the Development & Testing of Wave Energy Systems, OES-IA Annex II Task 2.1, Report T02-2.1 3. G. Agate, A. Amicarelli, M. Peviani, 2014, 'Analisi fluidodinamica di un prototipo per la conversione di energia da moto ondoso: ottimizzazione della componente fissa e stime preliminari di potenza assorbita con la girante', RSE Ricerca di Sistema, Report 14001669 4. G. Agate, A. Amicarelli, A. Danelli, M. Peviani, 2015, 'Ottimizzazione del disegno di un dispositivo di generazione d'energia dal moto ondoso: simulazioni numeriche e studi in vasca di laboratorio idraulico, RSE Ricerca di Sistema, Report 15000671 5. A. Agate, A. Amicarelli, A. Danelli, M. Peviani, 2015. 'Optimization of the WaveSAX device: numerical modelling and ocean wave basin tests', VI International Conference on Computational Methods in Marine Engineering MARINE 2015, Rome, Italy 6. A. Danelli, M. Peviani, 2016. 'Performance evaluation of an innovative device to transform wave power into electric energy in ports and harbours". CORE 2nd International Conference on Offshore Renewable Energy; Glasgow, UK 7. M. Peviani, A. Danelli, G. Agate, F. Thiebaut, 2014, 'WAVETUBE RSE1, addressed to test an innovative device to transform wave power into electric energy in ports and harbours', Infrastructure post access report in the MARINET project framework 8. M. Peviani, A. Danelli, G. Agate, S. Bourdier, 2015, WAVESAX RSE2, addressed to test an innovative device to transform wave power into electric energy in ports and harbours', Infrastructure post access report in the MARINET project framework.
Ramshur, John T; de Jongh Curry, Amy L; Waters, Robert S
2014-01-01
We describe for the first time the design, implementation, and testing of a telemetry controlled simultaneous stimulation and recording device (SRD) to deliver chronic intercortical microstimulation (ICMS) to physiologically identified sites in rat somatosensory cortex (SI) and test hypotheses that chronic ICMS strengthens interhemispheric pathways and leads to functional reorganization in the enhanced cortex. The SRD is a custom embedded device that uses the Cypress Semiconductor's programmable system on a chip (PSoC) that is remotely controlled via Bluetooth. The SRC can record single or multiunit responses from any two of 12 available inputs at 1-15 ksps per channel and simultaneously deliver stimulus pulses (0-255 μA; 10 V compliance) to two user selectable electrodes using monophasic, biphasic, or pseudophasic stimulation waveforms (duration: 0-5 ms, inter-phase interval: 0-5 ms, frequency: 0.1-5 s, delay: 0-10 ms). The SRD was bench tested and validated in vivo in a rat animal model.
Oral Fluid Testing for Drugs of Abuse
Bosker, Wendy M.; Huestis, Marilyn A.
2011-01-01
BACKGROUND Oral fluid (OF) is an exciting alternative matrix for monitoring drugs of abuse in workplace, clinical toxicology, criminal justice, and driving under the influence of drugs (DUID) programs. During the last 5 years, scientific and technological advances in OF collection, point-of-collection testing devices, and screening and confirmation methods were achieved. Guidelines were proposed for workplace OF testing by the Substance Abuse and Mental Health Services Administration, DUID testing by the European Union’s Driving under the Influence of Drugs, Alcohol and Medicines (DRUID) program, and standardization of DUID research. Although OF testing is now commonplace in many monitoring programs, the greatest current limitation is the scarcity of controlled drug administration studies available to guide interpretation. CONTENT This review outlines OF testing advantages and limitations, and the progress in OF that has occurred during the last 5 years in collection, screening, confirmation, and interpretation of cannabinoids, opioids, amphetamines, cocaine, and benzodiazepines. We examine controlled drug administration studies, immunoassay and chromatographic methods, collection devices, point-of-collection testing device performance, and recent applications of OF testing. SUMMARY Substance Abuse and Mental Health Services Administration approval of OF testing was delayed because questions about drug OF disposition were not yet resolved, and collection device performance and testing assays required improvement. Here, we document the many advances achieved in the use of OF. Additional research is needed to identify new bio-markers, determine drug detection windows, characterize OF adulteration techniques, and evaluate analyte stability. Nevertheless, there is no doubt that OF offers multiple advantages as an alternative matrix for drug monitoring and has an important role in DUID, treatment, workplace, and criminal justice programs. PMID:19745062
The effect of alpha rhythm sleep on EEG activity and individuals' attention.
Kim, Seon Chill; Lee, Myoung Hee; Jang, Chel; Kwon, Jung Won; Park, Joo Wan
2013-12-01
[Purpose] This study examined whether the alpha rhythm sleep alters the EEG activity and response time in the attention and concentration tasks. [Subjects and Methods] The participants were 30 healthy university students, who were randomly and equally divided into two groups, the experimental and control groups. They were treated using the Happy-sleep device or a sham device, respectively. All participants had a one-week training period. Before and after training sessions, a behavioral task test was performed and EEG alpha waves were measured to confirm the effectiveness of training on cognitive function. [Results] In terms of the behavioral task test, reaction time (RT) variations in the experimental group were significantly larger than in the control group for the attention item. Changes in the EEG alpha power in the experimental group were also significantly larger than those of the control group. [Conclusions] These findings suggest that sleep induced using the Happy-sleep device modestly enhances the ability to pay attention and focus during academic learning.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, Lynn; Perkins, Curtis; Smith, Aaron
The next wave of LED lighting technology is likely to be tunable white lighting (TWL) devices which can adjust the colour of the emitted light between warm white (~ 2700 K) and cool white (~ 6500 K). This type of lighting system uses LED assemblies of two or more colours each controlled by separate driver channels that independently adjust the current levels to achieve the desired lighting colour. Drivers used in TWL devices are inherently more complex than those found in simple SSL devices, due to the number of electrical components in the driver required to achieve this level ofmore » control. The reliability of such lighting systems can only be studied using accelerated stress tests (AST) that accelerate the aging process to time frames that can be accommodated in laboratory testing. This paper describes AST methods and findings developed from AST data that provide insights into the lifetime of the main components of one-channel and multi-channel LED devices. The use of AST protocols to confirm product reliability is necessary to ensure that the technology can meet the performance and lifetime requirements of the intended application.« less
Evaluation of the econo-mist device
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
The Emission Control Technology Division (ECTD) was contacted by the General Services Administration (GSA) concerning a vapor injection device for use with automobile engines. The device is called the Econo-Mist and is a product of the FAP Corporation of Albuquerque, New Mexico. GSA had received information that the Econo-Mist reduced hydrocarbon and carbon monoxide emissions and increased fuel economy. At the request of GSA, ECTD agreed to test the device. A sample of the device was brought to the EPA laboratory in Ann Arbor, Michigan by FAP Corporation personnel on January 13, 1975.
Chen, Hsing-Hsia; Yeh, Mei-Ling; Yang, Hui-Ju
2005-07-01
This study aimed to develop a multimedia video CD (VCD) of patient-controlled analgesia (PCA) and test its effects on pain knowledge and pain relief in patients receiving surgery. This multimedia VCD of PCA was created to convey fundamental knowledge to both patients and their family members and help patients properly utilize PCA devices to relieve pain and improve recovery. The content of multimedia VCD of PCA included pre-admission pain education, introduction of PCA, nursing care procedures, and questions and answers. This study used a quasi-experimental research design to test effects of the multimedia education program in the experimental group of 30 subjects compared to the control subjects of equal number (without the multimedia VCD of PCA). (1) The intervention of multimedia VCD of PCA resulted in a statistically significant difference in pain knowledge between the experimental and control groups. (2) Subjects in the experimental group obtained a better outcome of pain relief compared to control subjects. (3) Subjects in the experimental group indicated that the multimedia VCD of PCA indeed helped them effectively operate their PCA devices to relieve surgery pain. The clinical application of the multimedia VCD of PCA could help patients improve knowledge on pain, learn how to use PCA devices, achieve proper pain relief, and increase effectiveness of recovery activities.
Remotely accessible laboratory for MEMS testing
NASA Astrophysics Data System (ADS)
Sivakumar, Ganapathy; Mulsow, Matthew; Melinger, Aaron; Lacouture, Shelby; Dallas, Tim E.
2010-02-01
We report on the construction of a remotely accessible and interactive laboratory for testing microdevices (aka: MicroElectroMechancial Systems - MEMS). Enabling expanded utilization of microdevices for research, commercial, and educational purposes is very important for driving the creation of future MEMS devices and applications. Unfortunately, the relatively high costs associated with MEMS devices and testing infrastructure makes widespread access to the world of MEMS difficult. The creation of a virtual lab to control and actuate MEMS devices over the internet helps spread knowledge to a larger audience. A host laboratory has been established that contains a digital microscope, microdevices, controllers, and computers that can be logged into through the internet. The overall layout of the tele-operated MEMS laboratory system can be divided into two major parts: the server side and the client side. The server-side is present at Texas Tech University, and hosts a server machine that runs the Linux operating system and is used for interfacing the MEMS lab with the outside world via internet. The controls from the clients are transferred to the lab side through the server interface. The server interacts with the electronics required to drive the MEMS devices using a range of National Instruments hardware and LabView Virtual Instruments. An optical microscope (100 ×) with a CCD video camera is used to capture images of the operating MEMS. The server broadcasts the live video stream over the internet to the clients through the website. When the button is pressed on the website, the MEMS device responds and the video stream shows the movement in close to real time.
MOEMs devices designed and tested for future astronomical instrumentation in space
NASA Astrophysics Data System (ADS)
Zamkotsian, Frédéric; Lanzoni, Patrick; Waldis, Severin; Noell, Wilfried; Conedera, Veronique; Fabre, Norbert; Viard, Thierry; Buisset, Christophe
2017-11-01
Next generation of astronomical instrumentation for space telescopes requires Micro-Opto-Electro- Mechanical Systems (MOEMS) with remote control capability and cryogenic operation. MOEMS devices have the capability to tailor the incoming light in terms of intensity and object selection with programmable slit masks, in terms of phase and wavefront control with micro-deformable mirrors, and finally in terms of spectrum with programmable diffraction gratings. Applications are multi-object spectroscopy (MOS), wavefront correction and programmable spectrographs. We are engaged since several years in the design, realization and characterization of MOEMS devices suited for astronomical instrumentation.
Vaginal rings for delivery of HIV microbicides
Malcolm, R Karl; Fetherston, Susan M; McCoy, Clare F; Boyd, Peter; Major, Ian
2012-01-01
Following the successful development of long-acting steroid-releasing vaginal ring devices for the treatment of menopausal symptoms and contraception, there is now considerable interest in applying similar devices to the controlled release of microbicides against HIV. In this review article, the vaginal ring concept is first considered within the wider context of the early advances in controlled-release technology, before describing the various types of ring device available today. The remainder of the article highlights the key developments in HIV microbicide-releasing vaginal rings, with a particular focus on the dapivirine ring that is presently in late-stage clinical testing. PMID:23204872
Vaginal rings for delivery of HIV microbicides.
Malcolm, R Karl; Fetherston, Susan M; McCoy, Clare F; Boyd, Peter; Major, Ian
2012-01-01
Following the successful development of long-acting steroid-releasing vaginal ring devices for the treatment of menopausal symptoms and contraception, there is now considerable interest in applying similar devices to the controlled release of microbicides against HIV. In this review article, the vaginal ring concept is first considered within the wider context of the early advances in controlled-release technology, before describing the various types of ring device available today. The remainder of the article highlights the key developments in HIV microbicide-releasing vaginal rings, with a particular focus on the dapivirine ring that is presently in late-stage clinical testing.
A comparison of WEC control strategies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilson, David G.; Bacelli, Giorgio; Coe, Ryan Geoffrey
2016-04-01
The operation of Wave Energy Converter (WEC) devices can pose many challenging problems to the Water Power Community. A key research question is how to significantly improve the performance of these WEC devices through improving the control system design. This report summarizes an effort to analyze and improve the performance of WEC through the design and implementation of control systems. Controllers were selected to span the WEC control design space with the aim of building a more comprehensive understanding of different controller capabilities and requirements. To design and evaluate these control strategies, a model scale test-bed WEC was designed formore » both numerical and experimental testing (see Section 1.1). Seven control strategies have been developed and applied on a numerical model of the selected WEC. This model is capable of performing at a range of levels, spanning from a fully-linear realization to varying levels of nonlinearity. The details of this model and its ongoing development are described in Section 1.2.« less
30 CFR 74.6 - Quality control.
Code of Federal Regulations, 2010 CFR
2010-07-01
... DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust Personal Sampler Unit § 74.6 Quality... equipment procedures and records and to interview the employees who conduct the control tests. Two copies of...
Device Oriented Project Controller
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dalesio, Leo; Kraimer, Martin
2013-11-20
This proposal is directed at the issue of developing control systems for very large HEP projects. A de-facto standard in accelerator control is the Experimental Physics and Industrial Control System (EPICS), which has been applied successfully to many physics projects. EPICS is a channel based system that requires that each channel of each device be configured and controlled. In Phase I, the feasibility of a device oriented extension to the distributed channel database was demonstrated by prototyping a device aware version of an EPICS I/O controller that functions with the current version of the channel access communication protocol. Extensions havemore » been made to the grammar to define the database. Only a multi-stage position controller with limit switches was developed in the demonstration, but the grammar should support a full range of functional record types. In phase II, a full set of record types will be developed to support all existing record types, a set of process control functions for closed loop control, and support for experimental beam line control. A tool to configure these records will be developed. A communication protocol will be developed or extensions will be made to Channel Access to support introspection of components of a device. Performance bench marks will be made on both communication protocol and the database. After these records and performance tests are under way, a second of the grammar will be undertaken.« less
40 CFR 63.1188 - What performance test requirements must I meet?
Code of Federal Regulations, 2010 CFR
2010-07-01
... Performance Tests and Methods § 63.1188 What performance test requirements must I meet? You must meet the... numerical emission limit for PM, CO, or formaldehyde, or at the inlet and outlet of the control device if...
Microgrids | Grid Modernization | NREL
algorithms for microgrid integration Controller hardware-in-the-loop testing, where the physical controller interacts with a model of the microgrid and associated power devices Power hardware-in-the-loop testing of operation was validated in a power hardware-in-the-loop experiment using a programmable DC power supply to
Miniaturized haploscope for testing binocular vision
NASA Technical Reports Server (NTRS)
Decker, T. A.
1973-01-01
Device can reproduce virtually all binocular stimulus conditions (target configuration, vergence angle, and accommodative distance) used to test binocular performance. All subsystems of electronic controls are open-loop and solid-state-controlled and, with the exception of vergence angle drive, utilize dc stepping motors as prime movers. Arrangement is also made for readouts of each variable.
Comparison of Controlled Field Test Aerosol Generation Devices to a Laboratory Device
2013-11-01
detector, and it allows airflow through the region between its exhaust tube and the detector inlet tube. 2 The atomizer (Aerogen; Dangan, Galway ...Aerogen; Dangan, Galway , Ireland. http://www.aerogen.com/ aeroneb-go.html (accessed October 2013). Byron, P. Dosing Reproducibility from Experimental
Laupu, W; Brimacombe, J
2007-08-01
We tested the hypothesis that supplementary cleaning using potassium permanganate 8 mg.l(-1) eliminates protein deposits from the reusable metallic and synthetic rubber airway equipment. Twenty Macintosh laryngoscope blades (surgical steel), 20 pairs of Magill's forceps (surgical steel) and 20 Guedel airways (synthetic rubber) were allocated to two groups for supplementary cleaning. In group A, the device was immersed in potassium permanganate 8 mg.l(-1). In group B (controls), the device was immersed in sterile water. The devices were then immersed in a protein staining solution, rinsed and the severity of staining was scored. In addition, the devices were inspected for tissue and then tested for occult blood. Protein contamination was lower in the potassium permanganate group for all devices (each device: p < 0.0001). There was no staining detected in the permanganate group. In the permanganate group, dried tissue was detected in the teeth of one pair of forceps, which was not detected following supplementary cleaning. Additionally, occult blood was detected on two pairs of forceps and a laryngoscope blade, which was not detected following supplementary cleaning. In the control group, no tissue was detected but one pair of forceps and two laryngoscope blades tested positive for occult blood before and after supplementary cleaning. We conclude that supplementary cleaning using potassium permanganate 8 mg.l(-1) eliminates protein deposits from re-usable metallic and synthetic rubber airway equipment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, Xiangqi; Zhang, Yingchen
This paper presents an optimal voltage control methodology with coordination among different voltage-regulating resources, including controllable loads, distributed energy resources such as energy storage and photovoltaics (PV), and utility voltage-regulating devices such as voltage regulators and capacitors. The proposed methodology could effectively tackle the overvoltage and voltage regulation device distortion problems brought by high penetrations of PV to improve grid operation reliability. A voltage-load sensitivity matrix and voltage-regulator sensitivity matrix are used to deploy the resources along the feeder to achieve the control objectives. Mixed-integer nonlinear programming is used to solve the formulated optimization control problem. The methodology has beenmore » tested on the IEEE 123-feeder test system, and the results demonstrate that the proposed approach could actively tackle the voltage problem brought about by high penetrations of PV and improve the reliability of distribution system operation.« less
NASA Technical Reports Server (NTRS)
Hewes, D. E.; Glover, K. E.
1975-01-01
A Skylab experiment was conducted to study the maneuvering capabilities of astronauts using a relatively simple self-locomotive device, referred to as the foot-controlled maneuvering unit, and to evaluate the effectiveness of ground-based facilities simulating the operation of this device in weightless conditions of space. Some of the special considerations given in the definition and development of the experiment as related to the two ground-based simulators are reviewed. These simulators were used to train the test subjects and to obtain baseline data which could be used for comparison with the in-flight tests that were performed inside the Skylab orbital workshop. The results of both premission and postmission tests are discussed, and subjective comparisons of the in-flight and ground-based test conditions are presented.
NASA Astrophysics Data System (ADS)
Nikitin, Alexander N.; Baryshnikov, Nikolay; Denisov, Dmitrii; Karasik, Valerii; Sakharov, Alexey; Romanov, Pavel; Sheldakova, Julia; Kudryashov, Alexis
2018-02-01
In this paper we consider two approaches widely used in testing of spherical optical surfaces: Fizeau interferometer and Shack-Hartmann wavefront sensor. Fizeau interferometer that is widely used in optical testing can be transformed to a device using Shack-Hartmann wavefront sensor, the alternative technique to check spherical optical components. We call this device Hartmannometer, and compare its features to those of Fizeau interferometer.
Auditory Localization Performance with Gamma Integrated Eye and Ear Protection
2016-12-01
is unlimited. v List of Figures Fig. 1 IEEP device under test: shown with clear ballistic lens and Comply foam earphone tips...conducted with the system active. Fig. 1 IEEP device under test: shown with clear ballistic lens and Comply foam earphone tips. 1.2 Auditory...controlled acoustic facilities with large loudspeaker arrays. Method 1 has 2 listener orientations (0° and 45°) and specifies the use of 8
Coordinate control of initiative mating device for autonomous underwater vehicle based on TDES
NASA Astrophysics Data System (ADS)
Yan, Zhe-Ping; Hou, Shu-Ping
2005-06-01
A novel initiative mating device, which has four 2-degree manipulators around the mating skirt, is proposed to mate between a skirt of AUV (autonomons underwater vehicle) and a disabled submarine. The primary function of the device is to keep exact mating between skirt and disabled submarine in a badly sub sea environment. According to the characteristic of rescue, an automaton model is brought foward to describe the mating proceed between AUV and manipulators. The coordinated control is implemented by the TDES (time discrete event system). After taking into account the time problem, it is a useful method to control mating by simulation testing. The result shows that it reduces about 70 seconds after using intelligent co-ordinate control based on TDES through the whole mating procedure.
Quantitative assessment of four men using above-elbow prosthetic control.
Popat, R A; Krebs, D E; Mansfield, J; Russell, D; Clancy, E; Gill-Body, K M; Hogan, N
1993-07-01
We studied the relationship between kinematically unconstrained activities of daily living (ADL) tasks and a kinematically constrained task in above-elbow (AE) amputee subjects using myoelectrically controlled prostheses. Four men, 24 to 49 years old, with unilateral AE amputation wore a prosthesis interfaced to a programmable controller to emulate two different elbow control schemes, conventional velocity and a new "natural" controller. Subjects were timed during three ADL tasks--cutting meat, donning socks, and rolling dough--with both controllers. The prosthesis emulator was then connected to a crank device with a handle, and the subjects turned the crank from bottom to top positions in a vertical plane using each controller. Synergistic shoulder-elbow joint coordination required for crank turning was quantified as the maximum slope of the change in elbow torque versus the change in crank-angle. Performance between the two controllers differed significantly for the crank test but not for ADL tasks. One subject did not complete all crank turning tests. Positive canonical correlation of 0.77 was found between time and crank domain measures. We conclude that biomechanical assessments should be integrated with time-based clinical tests to comprehensively evaluate performance of AE amputee subjects with a myoelectric device.
Quality Control Method for a Micro-Nano-Channel Microfabricated Device
NASA Technical Reports Server (NTRS)
Grattoni, Alessandro; Ferrari, Mauro; Li, Xuewu
2012-01-01
A variety of silicon-fabricated devices is used in medical applications such as drug and cell delivery, and DNA and protein separation and analysis. When a fluidic device inlet is connected to a compressed gas reservoir, and the outlet is at a lower pressure, a gas flow occurs through the membrane toward the outside. The method relies on the measurement of the gas pressure over the elapsed time inside the upstream and downstream environments. By knowing the volume of the upstream reservoir, the gas flow rate through the membrane over the pressure drop can be calculated. This quality control method consists of measuring the gas flow through a device and comparing the results with a standard curve, which can be obtained by testing standard devices. Standard devices can be selected through a variety of techniques, both destructive and nondestructive, such as SEM, AFM, and standard particle filtration.
NASA Technical Reports Server (NTRS)
Moskovitz, Cary A.; Hall, Robert M.; Dejarnette, F. R.
1990-01-01
An exploratory experimental investigation of a new device to control the asymmetric flowfield on forebodies at large angles of attack has been conducted. The device is a rotatable forebody tip, which varies in cross section from circular at its base to elliptic at its tip. The device itself extends over a small portion of the aircraft or missile forebody. The device provides two important improvements. First, it replaced the normally random behavior of the nose side force as a function of nose tip orientation with a predictable and generally sinusoidal distribution and, second, the device showed promise for use as part of a vehicle control system, to be deflected in a prescribed manner to provide additional directional control for the vehicle. The device was tested on a cone/cylinder model having a 10 deg semiapex angle and on a 3.0 caliber tangent ogive model, each with a base diameter of 3.5 in, for angles of attack from 30 to 60 deg. Data were taken from 3 circumferential rows of pressure taps on each model at a Reynolds number of 84,000 based on cylinder diameter and by a helium-bubble flow visualization technique at a Reynolds number of 24,000.
Annular Momentum Control Device (AMCD). Volume 1: Laboratory model development
NASA Technical Reports Server (NTRS)
1975-01-01
The annular momentum control device (AMCD) a thin hoop-like wheel with neither shaft nor spokes is described. The wheel floats in a magnetic field and can be rotated by a segmented motor. Potential advantages of such a wheel are low weight, configuration flexibility, a wheel that stiffens with increased speed, vibration isolation, and increased reliability. The analysis, design, fabrication, and testing is described of the laboratory model of the AMCD.
Serial Interface through Stream Protocol on EPICS Platform for Distributed Control and Monitoring
NASA Astrophysics Data System (ADS)
Das Gupta, Arnab; Srivastava, Amit K.; Sunil, S.; Khan, Ziauddin
2017-04-01
Remote operation of any equipment or device is implemented in distributed systems in order to control and proper monitoring of process values. For such remote operations, Experimental Physics and Industrial Control System (EPICS) is used as one of the important software tool for control and monitoring of a wide range of scientific parameters. A hardware interface is developed for implementation of EPICS software so that different equipment such as data converters, power supplies, pump controllers etc. could be remotely operated through stream protocol. EPICS base was setup on windows as well as Linux operating system for control and monitoring while EPICS modules such as asyn and stream device were used to interface the equipment with standard RS-232/RS-485 protocol. Stream Device protocol communicates with the serial line with an interface to asyn drivers. Graphical user interface and alarm handling were implemented with Motif Editor and Display Manager (MEDM) and Alarm Handler (ALH) command line channel access utility tools. This paper will describe the developed application which was tested with different equipment and devices serially interfaced to the PCs on a distributed network.
Mitigating operating room fires: development of a carbon dioxide fire prevention device.
Culp, William C; Kimbrough, Bradly A; Luna, Sarah; Maguddayao, Aris J
2014-04-01
Operating room fires are sentinel events that present a real danger to surgical patients and occur at least as frequently as wrong-sided surgery. For fire to occur, the 3 points of the fire triad must be present: an oxidizer, an ignition source, and fuel source. The electrosurgical unit (ESU) pencil triggers most operating room fires. Carbon dioxide (CO2) is a gas that prevents ignition and suppresses fire by displacing oxygen. We hypothesize that a device can be created to reduce operating room fires by generating a cone of CO2 around the ESU pencil tip. One such device was created by fabricating a divergent nozzle and connecting it to a CO2 source. This device was then placed over the ESU pencil, allowing the tip to be encased in a cone of CO2 gas. The device was then tested in 21%, 50%, and 100% oxygen environments. The ESU was activated at 50 W cut mode while placing the ESU pencil tip on a laparotomy sponge resting on an aluminum test plate for up to 30 seconds or until the sponge ignited. High-speed videography was used to identify time of ignition. Each test was performed in each oxygen environment 5 times with the device activated (CO2 flow 8 L/min) and with the device deactivated (no CO2 flow-control). In addition, 3-dimensional spatial mapping of CO2 concentrations was performed with a CO2 sampling device. The median ± SD [range] ignition time of the control group in 21% oxygen was 2.9 s ± 0.44 [2.3-3.0], in 50% oxygen 0.58 s ± 0.12 [0.47-0.73], and in 100% oxygen 0.48 s ± 0.50 [0.03-1.27]. Fires were ignited with each control trial (15/15); no fires ignited when the device was used (0/15, P < 0.0001). The CO2 concentration at the end of the ESU pencil tip was 95%, while the average CO2 concentration 1 to 1.4 cm away from the pencil tip on the bottom plane was 64%. In conclusion, an operating room fire prevention device can be created by using a divergent nozzle design through which CO2 passes, creating a cone of fire suppressant. This device as demonstrated in a flammability model effectively reduced the risk of fire. CO2 3-dimensional spatial mapping suggests effective fire reduction at least 1 cm away from the tip of the ESU pencil at 8 L/min CO2 flow. Future testing should determine optimum CO2 flow rates and ideal nozzle shapes. Use of this device may substantially reduce the risk of patient injury due to operating room fires.
Control Board Digital Interface Input Devices – Touchscreen, Trackpad, or Mouse?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomas A. Ulrich; Ronald L. Boring; Roger Lew
The authors collaborated with a power utility to evaluate input devices for use in the human system interface (HSI) for a new digital Turbine Control System (TCS) at a nuclear power plant (NPP) undergoing a TCS upgrade. A standalone dynamic software simulation of the new digital TCS and a mobile kiosk were developed to conduct an input device study to evaluate operator preference and input device effectiveness. The TCS software presented the anticipated HSI for the TCS and mimicked (i.e., simulated) the turbine systems’ responses to operator commands. Twenty-four licensed operators from the two nuclear power units participated in themore » study. Three input devices were tested: a trackpad, mouse, and touchscreen. The subjective feedback from the survey indicates the operators preferred the touchscreen interface. The operators subjectively rated the touchscreen as the fastest and most comfortable input device given the range of tasks they performed during the study, but also noted a lack of accuracy for selecting small targets. The empirical data suggest the mouse input device provides the most consistent performance for screen navigation and manipulating on screen controls. The trackpad input device was both empirically and subjectively found to be the least effective and least desired input device.« less
2000-04-07
The Food and Drug Administration (FDA) is reclassifying over-the-counter (OTC) test sample collection systems for drugs of abuse testing from class III (premarket approval) into class I (general controls) and exempting them from premarket notification (510(k)) and current good manufacturing practice (CGMP) requirements. FDA is also designating OTC test sample collection systems for drugs of abuse testing as restricted devices under the Federal Food, Drug, and Cosmetic Act (the act) and establishing restrictions intended to assure consumers that: The underlying laboratory test(s) are accurate and reliable; the laboratory performing the test(s) has adequate expertise and competency; and the product has adequate labeling and methods of communicating test results to consumers. Finally, FDA is adding a conforming amendment to the existing classification regulation for specimen transport and storage containers to clarify that it does not apply to specimen transport and storage containers that are part of an OTC test sample collection system for the purpose of testing for the presence of drugs of abuse or their metabolites in a laboratory.
Houlbert, C; Annaix, V; Szymanowicz, A; Vassault, A; Guimont, M C; Pernet, P
2012-02-01
In this paper, guidelines are proposed to fulfill the requirements of EN ISO 22870 standard regarding the management of point-of-care testing (POCT) nonconformities. In the first part, the main nonconformities that may affect POCT are given, the means for resolution and the control of adverse events are proposed. In the second part, we propose recommendations in case of unavailability of a point-of-care testing device from the occurring of the adverse event, to the restarting of the device.
The Environmental Technology Verification report discusses the technology and performance of the Lubrizol Engine Control Systems Purifilter SC17L manufactured by Lubrizol Engine Control Systems. The technology is a precious and base metal, passively regenerated particulate filter...
Pressure-Application Device for Testing Pressure Sensors
NASA Technical Reports Server (NTRS)
2002-01-01
A portable pressure-application device has been designed and built for use in testing and calibrating piezoelectric pressure transducers in the field. The device generates pressure pulses of known amplitude. A pressure pulse (in contradistinction to a steady pressure) is needed because in the presence of a steady pressure, the electrical output of a piezoelectric pressure transducer decays rapidly with time. The device includes a stainless- steel compressed-air-storage cylinder of 500 cu cm volume. A manual hand pump with check valves and a pressure gauge are located at one end of the cylinder. A three-way solenoid valve that controls the release of pressurized air is located at the other end of the cylinder. Power for the device is provided by a 3.7-V cordless-telephone battery. The valve is controlled by means of a pushbutton switch, which activates a 5 V to +/-15 V DC-to-DC converter that powers the solenoid. The outlet of the solenoid valve is connected to the pressure transducer to be tested. Before the solenoid is energized, the transducer to be tested is at atmospheric pressure. When the solenoid is actuated by the push button, pressurized air from inside the cylinder is applied to the transducer. Once the pushbutton is released, the cylinder pressure is removed from the transducer and the pressurized air applied to the transducer is vented, bringing the transducer back to atmospheric pressure. Before this device was used for actual calibration, its accuracy was checked with a NIST (National Institute of Standards and Technology) traceable calibrator and commercially calibrated pressure transducers. This work was done by Wanda Solano of Stennis Space Center and Greg Richardson of Lockheed Martin Corp.
Evaluation of X-38 Crew Return Vehicle Input Control Devices in a Microgravity Environment
NASA Technical Reports Server (NTRS)
Welge, Kirsten; Moore, Alicia; Pope, Ruth Ann; Shivers, Suzette; Fox, Jeffrey
2000-01-01
This report was created by students from Longview High School, Longview, Texas. Longview High School was selected from a group of Texas high schools to participate in the 1999 Texas Fly High Program. This program gives Texas high school students a chance to work with NASA engineers to design and fly a real-world experiment aboard the KC-135 during zero-g parabolas. Jeffrey Fox's role was to provide a concept for the experiment and to mentor the students in its design and testing. The students were responsible for executing all phases of the project. The X-38 Project Office at the Lyndon B. Johnson Space Center Johnson Space is designing a crew return vehicle (CRV) to be docked at the International Space Station for crew rescue in an emergency. Vehicle controls will be almost completely automated, but a few functions will be manually controlled. Four crew input control devices were selected for evaluation by Longview High School students as part of the 1999 Texas Fly High program. These were (1) Logitech Trackman Marble (optical trackball), (2) Smart Cat Touchpad. (3) Microsoft SideWinder 3D-Pro Joystick, and (4) Microsoft SideWinder Gamepad. In two flight tests in the KC-135 aircraft and a series of ground tests, the devices were evaluated for ability to maneuver an on-screen cursor, level of accuracy, ease of handling blind operations, and level of user comfort in microgravity. The tests results led to recommendation of further tests with the Joystick and the Trackman by astronauts and actual space station residents.
Florida alternative NTCIP testing software (ANTS) for actuated signal controllers.
DOT National Transportation Integrated Search
2009-01-01
The scope of this research project did include the development of a software tool to test devices for NTCIP compliance. Development of the Florida Alternative NTCIP Testing Software (ANTS) was developed by the research team due to limitations found w...
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
The National Renewable Energy Laboratory's (NREL) controllable grid interface (CGI) test system at the National Wind Technology Center (NWTC) is one of two user facilities at NREL capable of testing and analyzing the integration of megawatt-scale renewable energy systems. The CGI specializes in testing of multimegawatt-scale wind and photovoltaic (PV) technologies as well as energy storage devices, transformers, control and protection equipment at medium-voltage levels, allowing the determination of the grid impacts of the tested technology.
Active Control Technology at NASA Langley Research Center
NASA Technical Reports Server (NTRS)
Antcliff, Richard R.; McGowan, Anna-Marie R.
2000-01-01
NASA Langley has a long history of attacking important technical Opportunities from a broad base of supporting disciplines. The research and development at Langley in this subject area range from the test tube to the test flight, The information covered here will range from the development of innovative new materials, sensors and actuators, to the incorporation of smart sensors and actuators in practical devices, to the optimization of the location of these devices, to, finally, a wide variety of applications of these devices utilizing Langley's facilities and expertise. Advanced materials are being developed for sensors and actuators, as well as polymers for integrating smart devices into composite structures. Contributions reside in three key areas: computational materials; advanced piezoelectric materials; and integrated composite structures.
Embedded Control System for Smart Walking Assistance Device.
Bosnak, Matevz; Skrjanc, Igor
2017-03-01
This paper presents the design and implementation of a unique control system for a smart hoist, a therapeutic device that is used in rehabilitation of walking. The control system features a unique human-machine interface that allows the human to intuitively control the system just by moving or rotating its body. The paper contains an overview of the complete system, including the design and implementation of custom sensors, dc servo motor controllers, communication interfaces and embedded-system based central control system. The prototype of the complete system was tested by conducting a 6-runs experiment on 11 subjects and results are showing that the proposed control system interface is indeed intuitive and simple to adopt by the user.
77 FR 38769 - 97th Annual Meeting of the National Conference on Weights and Measures
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-29
... testing equipment that comprise the regulatory control of commercial weighing and measuring devices. The... specifications to recognize current marketing practices of offering pre or post delivery discounts on fuel prices... proposal would allow device manufacturers greater flexibility in the design and operation of customer...
NASA Astrophysics Data System (ADS)
Fugett, James H.; Bennett, Haydon E.; Shrout, Joshua L.; Coad, James E.
2017-02-01
Expansions in minimally invasive medical devices and technologies with thermal mechanisms of action are continuing to advance the practice of medicine. These expansions have led to an increasing need for appropriate animal models to validate and quantify device performance. The planning of these studies should take into consideration a variety of parameters, including the appropriate animal model (test system - ex vivo or in vivo; species; tissue type), treatment conditions (test conditions), predicate device selection (as appropriate, control article), study timing (Day 0 acute to more than Day 90 chronic survival studies), and methods of tissue analysis (tissue dissection - staining methods). These considerations are discussed and illustrated using the fresh extirpated porcine longissimus muscle model for endometrial ablation.
Pain control in orthodontics using a micropulse vibration device: A randomized clinical trial.
Lobre, Wendy D; Callegari, Brent J; Gardner, Gary; Marsh, Curtis M; Bush, Anneke C; Dunn, William J
2016-07-01
To investigate the relationship between a micropulse vibration device and pain perception during orthodontic treatment. This study was a parallel group, randomized clinical trial. A total of 58 patients meeting eligibility criteria were assigned using block allocation to one of two groups: an experimental group using the vibration device or a control group (n = 29 for each group). Patients used the device for 20 minutes daily. Patients rated pain intensity on a visual analog scale at appropriate intervals during the weeks after the separator or archwire appointment. Data were analyzed using repeated measures analysis of variance at α = .05. During the 4-month test period, significant differences between the micropulse vibration device group and the control group for overall pain (P = .002) and biting pain (P = .003) were identified. The authors observed that perceived pain was highest at the beginning of the month, following archwire adjustment. The micropulse vibration device significantly lowered the pain scores for overall pain and biting pain during the 4-month study period.
Handbook for Driving Knowledge Testing.
ERIC Educational Resources Information Center
Pollock, William T.; McDole, Thomas L.
Materials intended for driving knowledge test development for use by operational licensing and education agencies are presented. A pool of 1,313 multiple choice test items is included, consisting of sets of specially developed and tested items covering principles of safe driving, legal regulations, and traffic control device knowledge pertinent to…
Research notes : light tube leads the way.
DOT National Transportation Integrated Search
2000-09-01
Recently, Oregon Department of Transportation (ODOT) tested a traffic control device designed to improve delineation of curves through highway construction projects. The 3M Lighted Guidance Tube (LGT) was tested on the Eddyville-Cline Hill Section...
Integration of a mechanical forebody vortex control system into the F-15
NASA Technical Reports Server (NTRS)
Boalbey, Richard E.; Citurs, Kevin D.; Ely, Wayne L.; Harbaugh, Stephen P.; Hollingsworth, William B.; Phillips, Ronald L.
1994-01-01
The goal of the F-15 Forebody Vortex Control (FVC) program is to develop a production FVC system for the F-15. The system may consist of either a mechanically actuated device such as the strakes developed for the HARV program, or a pneumatic device such as the port blowing system being tested on the X-29. Both types of systems are being evaluated under this program. Background information on the F-15 and a description and overview of forebody vortex controls (FVC) will be presented.
Piezoelectric pushers for active vibration control of rotating machinery
NASA Technical Reports Server (NTRS)
Palazzolo, Alan B.; Kascak, Albert F.
1988-01-01
The active control of rotordynamic vibrations and stability by magnetic bearings and electromagnetic shakers have been discussed extensively in the literature. These devices, though effective, are usually large in volume and add significant weight to the stator. The use of piezoelectric pushers may provide similar degrees of effectiveness in light, compact packages. Tests are currently being conducted with piezoelectric pusher-based active vibration control. Results from tests performed on NASA test rigs as preliminary verification of the related theory are presented.
Piezoelectric pushers for active vibration control of rotating machinery
NASA Technical Reports Server (NTRS)
Palazzolo, A. B.; Lin, R. R.; Alexander, R. M.; Kascak, A. F.; Montague, J.
1989-01-01
The active control of rotordynamic vibrations and stability by magnetic bearings and electromagnetic shakers have been discussed extensively in the literature. These devices, though effective, are usually large in volume and add significant weight to the stator. The use of piezoelectric pushers may provide similar degrees of effectiveness in light, compact packages. Tests are currently being conducted with piezoelectric pusher-based active vibration control. Results from tests performed on NASA test rigs as preliminary verification of the related theory are presented.
A programmable heater control circuit for spacecraft
NASA Technical Reports Server (NTRS)
Nguyen, D. D.; Owen, J. W.; Smith, D. A.; Lewter, W. J.
1994-01-01
Spacecraft thermal control is accomplished for many components through use of multilayer insulation systems, electrical heaters, and radiator systems. The heaters are commanded to maintain component temperatures within design specifications. The programmable heater control circuit (PHCC) was designed to obtain an effective and efficient means of spacecraft thermal control. The hybrid circuit provides use of control instrumentation as temperature data, available to the spacecraft central data system, reprogramming capability of the local microprocessor during the spacecraft's mission, and the elimination of significant spacecraft wiring. The hybrid integrated circuit has a temperature sensing and conditioning circuit, a microprocessor, and a heater power and control circuit. The device is miniature and housed in a volume which allows physical integration with the component to be controlled. Applications might include alternate battery-powered logic-circuit configurations. A prototype unit with appropriate physical and functional interfaces was procured for testing. The physical functionality and the feasibility of fabrication of the hybrid integrated circuit were successfully verified. The remaining work to develop a flight-qualified device includes fabrication and testing of a Mil-certified part. An option for completing the PHCC flight qualification testing is to enter into a joint venture with industry.
Oilwell Power Controller (OPC)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1993-08-01
The Oil Well Power Controller (OPC) prototype units is nearing completion. This device is an oilwell beam pump controller and data logger. Applications for this device have been for an electrical power saving device, pump off control, parafffin detection, demand power load control, chemical treatment data, dynamometer and pump efficiency data. Preliminary results appear vary promising. A total of ten OPC rod pump controllers were assembled and installed on oilwells in several areas of Central and Western United States. Data was analyzed on these wells and forwarded to the participating oil companies. Cost savings on each individual oil well participatingmore » in the OPC testing vary considerably, savings on some situations have been outstanding. In situations where the pump efficiency was determined to be low, the cost savings have been considerable. Cost savings due to preventive maintenance are also present, but are difficult to pin point an exact dollar amount at the present time. A break out of actual cost data obtained on some of the oilwells controlled and monitored with the oilwell power controller.« less
Progress of artificial pancreas devices towards clinical use: the first outpatient studies.
Russell, Steven J
2015-04-01
This article describes recent progress in the automated control of glycemia in type 1 diabetes with artificial pancreas devices that combine continuous glucose monitoring with automated decision-making and insulin delivery. After a gestation period of closely supervised feasibility studies in research centers, the last 2 years have seen publication of studies testing these devices in outpatient environments, and many more such studies are ongoing. The most basic form of automation, suspension of insulin delivery for actual or predicted hypoglycemia, has been shown to be effective and well tolerated, and a first-generation device has actually reached the market. Artificial pancreas devices that actively dose insulin fall into two categories, those that dose insulin alone and those that also use glucagon to prevent and treat hypoglycemia (bihormonal artificial pancreas). Initial outpatient clinical trials have shown that both strategies can improve glycemic management in comparison with patient-controlled insulin pump therapy, but only the bihormonal strategy has been tested without restrictions on exercise. Artificial pancreas technology has the potential to reduce acute and chronic complications of diabetes and mitigate the burden of diabetes self-management. Successful outpatient studies bring these technologies one step closer to availability for patients.
van den Boer, Cindy; Vas Nunes, Jonathan H; Muller, Sara H; van der Noort, Vincent; van den Brekel, Michiel W M; Hilgers, Frans J M
2014-06-01
After total laryngectomy, patients suffer from pulmonary complaints due to the shortcut of the upper airways that results in decreased warming and humidification of inspired air. Laryngectomized patients are advised to use a heat and moisture exchanger (HME) to optimize the inspired air. According to manufacturers' guidelines, these medical devices should be replaced every 24 hours. The aim of this study is to determine whether HMEs still function after 24-hour tracheostoma application. Assessment of residual water uptake capacity of used HMEs by measuring the difference between wet and dry core weight. Tertiary comprehensive cancer center. Three hygroscopic HME types were tested after use by laryngectomized patients in long-term follow-up. Water uptake of 41 used devices (including 10 prematurely replaced devices) was compared with that of control (unused) devices of the same type and with a control device with a relatively low performance. After 24 hours, the mean water uptake of the 3 device types had decreased compared with that of the control devices. For only one type was this difference significant. None of the used HMEs had a water uptake lower than that of the low-performing control device. The water uptake capacity of hygroscopic HEMs is clinically acceptable although no longer optimal after 24-hour tracheostoma application. From a functional point of view, the guideline for daily device replacement is therefore justified. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2014.
Gölcük, Adem; Güler, İnan
2017-01-01
This article proposes the employment of a proportional valve that can calculate the amount of oxygen in the air to be given to patient in accordance with the amount of FiO 2 which is set from the control menu of the ventilation device. To actualize this, a stepper motor-controlled proportional valve was used. Two counts of valves were employed in order to control the gases with 2 bar pressure that came from both the oxygen and medical air tanks. Oxygen and medical air manometers alongside the pressure regulators were utilized to perform this task. It is a fuzzy-logic-based controller which calculates at what rate the proportional valves will be opened and closed for FiO 2 calculation. Fluidity and pressure of air given by the ventilation device were tested with a FlowMeter while the oxygen level was tested using the electronic lung model. The obtained results from the study revealed that stepper motor controlled proportional valve could be safely used in ventilation devices. In this article, it was indicated that fluidity and pressure control could be carried out with just two counts of proportional valve, which could be done with many solenoid valves, so this reduces the cost of ventilator, electrical power consumed by the ventilator, and the dimension of ventilator.
NASA Technical Reports Server (NTRS)
Ukanwa, A. O.; Stermole, F. J.; Golden, J. O.
1972-01-01
Natural convection effects in phase change thermal control devices were studied. A mathematical model was developed to evaluate natural convection effects in a phase change test cell undergoing solidification. Although natural convection effects are minimized in flight spacecraft, all phase change devices are ground tested. The mathematical approach to the problem was to first develop a transient two-dimensional conduction heat transfer model for the solidification of a normal paraffin of finite geometry. Next, a transient two-dimensional model was developed for the solidification of the same paraffin by a combined conduction-natural-convection heat transfer model. Throughout the study, n-hexadecane (n-C16H34) was used as the phase-change material in both the theoretical and the experimental work. The models were based on the transient two-dimensional finite difference solutions of the energy, continuity, and momentum equations.
Specifics of Pulsed Arc Welding Power Supply Performance Based On A Transistor Switch
NASA Astrophysics Data System (ADS)
Krampit, N. Yu; Kust, T. S.; Krampit, M. A.
2016-08-01
Specifics of designing a pulsed arc welding power supply device are presented in the paper. Electronic components for managing large current was analyzed. Strengths and shortcomings of power supply circuits based on thyristor, bipolar transistor and MOSFET are outlined. As a base unit for pulsed arc welding was chosen MOSFET transistor, which is easy to manage. Measures to protect a transistor are given. As for the transistor control device is a microcontroller Arduino which has a low cost and adequate performance of the work. Bead transfer principle is to change the voltage on the arc in the formation of beads on the wire end. Microcontroller controls transistor when the arc voltage reaches the threshold voltage. Thus there is a separation and transfer of beads without splashing. Control strategies tested on a real device and presented. The error in the operation of the device is less than 25 us, it can be used controlling drop transfer at high frequencies (up to 1300 Hz).
40 CFR 1051.205 - What must I include in my application?
Code of Federal Regulations, 2014 CFR
2014-07-01
... emission control devices (AECDs) and all fuel-system components you will install on any production or test... specifications and other basic parameters of the vehicle's design and emission controls. List the fuel type on... scheduled maintenance you did. (g) List the specifications of the test fuel to show that it falls within the...
40 CFR 1051.205 - What must I include in my application?
Code of Federal Regulations, 2012 CFR
2012-07-01
... emission control devices (AECDs) and all fuel-system components you will install on any production or test... specifications and other basic parameters of the vehicle's design and emission controls. List the fuel type on... scheduled maintenance you did. (g) List the specifications of the test fuel to show that it falls within the...
40 CFR 1051.205 - What must I include in my application?
Code of Federal Regulations, 2013 CFR
2013-07-01
... emission control devices (AECDs) and all fuel-system components you will install on any production or test... specifications and other basic parameters of the vehicle's design and emission controls. List the fuel type on... scheduled maintenance you did. (g) List the specifications of the test fuel to show that it falls within the...
40 CFR 1051.205 - What must I include in my application?
Code of Federal Regulations, 2011 CFR
2011-07-01
... emission control devices (AECDs) and all fuel-system components you will install on any production or test... specifications and other basic parameters of the vehicle's design and emission controls. List the fuel type on... scheduled maintenance you did. (g) List the specifications of the test fuel to show that it falls within the...
This report reflects verification testing of a catalytic muffler for diesel trucks. Produced by Donaldson Corp., it was tested on low sulfur and ultra low sulfur fuel, and shown to have reduced emissions.
21 CFR 862.1460 - Leucine aminopeptidase test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Systems § 862.1460 Leucine aminopeptidase test system. (a) Identification. A leucine aminopeptidase test system is a device intended to measure the activity of the enzyme leucine amino-peptidase in serum... diseases such as viral hepatitis and obstructive jaundice. (b) Classification. Class I (general controls...
21 CFR 862.1460 - Leucine aminopeptidase test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Systems § 862.1460 Leucine aminopeptidase test system. (a) Identification. A leucine aminopeptidase test system is a device intended to measure the activity of the enzyme leucine amino-peptidase in serum... diseases such as viral hepatitis and obstructive jaundice. (b) Classification. Class I (general controls...
[Study on Intelligent Automatic Tracking Radiation Protection Curtain].
Zhao, Longyang; Han, Jindong; Ou, Minjian; Chen, Jinlong
2015-09-01
In order to overcome the shortcomings of traditional X-ray inspection taking passive protection mode, this paper combines the automatic control technology, puts forward a kind of active protection X-ray equipment. The device of automatic detection of patients receiving X-ray irradiation part, intelligent adjustment in patients and shooting device between automatic tracking radiation protection device height. The device has the advantages of automatic adjustment, anti-radiation device, reduce the height of non-irradiated area X-ray radiation and improve the work efficiency. Testing by the professional organization, the device can decrease more than 90% of X-ray dose for patients with non-irradiated area.
NASA Astrophysics Data System (ADS)
Puffer, Andrew J.
Many vascular system problems stem from insufficient blood return flow to the heart. One of the main causes is a blockage within veins or arteries known as a blood clot, or thrombus. This can occur after trauma, surgery, or other phenomenological reasons. Each year in the U.S. more than 175,000 bypass procedures and more than 160,000 amputations resulting from peripheral vessel disease are performed. Clinical data indicates that clot removal devices and procedures can reduce the need for an amputation by 80 percent. Percutaneous thrombectomy refers to the removal of thrombus using catheter based non-surgical methods. The ultimate goal of any modality to treat these conditions of the arterial or venous system is to restore patency, quickly, safely, and cost effectively. Catheter directed thrombectomy and thrombolysis is less traumatic and avoids the morbidity and mortality associated with conventional surgical technique. As a result, there has been a push recently for the use of percutaneous mechanical thrombectomy (PMT) devices. However, all devices have their own set of drawbacks: distal embolization, vessel wall trauma, hemolysis, to name a few. Ongoing efforts have been made to create a prototype thrombectomy device that uses elements of superelastic nitinol (a type of shape memory alloy), that seeks to address some of the drawbacks of current devices. The prototype was designed and tested in a simulated human circulatory system along side a commercially available device (The DiverCE Clot Extraction Catheter). The test evaluated how well the devices minimized distal embolization of a human blood clot created in vitro.. Results of the testing showed that the prototype device created significantly less embolization when compared to the DiverCE particles greater than 102mum (p = 0.0332). Means were statistically not different for particles between 25mum and 102mum (p = 0.2454), and particles between 5mum and 25mum (p = 0.6524). In addition the prototype was shown to create insignificant embolization when compared to a control (p = 0.108). The DiverCE, on the other hand, was shown to create significant embolization when compared to a control (p = 0.027).
Lee, Karla C L; Baker, Luisa A; Stanzani, Giacomo; Alibhai, Hatim; Chang, Yu Mei; Jimenez Palacios, Carolina; Leckie, Pamela J; Giordano, Paola; Priestnall, Simon L; Antoine, Daniel J; Jenkins, Rosalind E; Goldring, Christopher E; Park, B Kevin; Andreola, Fausto; Agarwal, Banwari; Mookerjee, Rajeshwar P; Davies, Nathan A; Jalan, Rajiv
2015-09-01
In acute liver failure, severity of liver injury and clinical progression of disease are in part consequent upon activation of the innate immune system. Endotoxaemia contributes to innate immune system activation and the detoxifying function of albumin, critical to recovery from liver injury, is irreversibly destroyed in acute liver failure. University College London-Liver Dialysis Device is a novel artificial extracorporeal liver assist device, which is used with albumin infusion, to achieve removal and replacement of dysfunctional albumin and reduction in endotoxaemia. We aimed to test the effect of this device on survival in a pig model of acetaminophen-induced acute liver failure. Pigs were randomised to three groups: Acetaminophen plus University College London-Liver Dialysis Device (n=9); Acetaminophen plus Control Device (n=7); and Control plus Control Device (n=4). Device treatment was initiated two h after onset of irreversible acute liver failure. The Liver Dialysis Device resulted in 67% reduced risk of death in acetaminophen-induced acute liver failure compared to Control Device (hazard ratio=0.33, p=0.0439). This was associated with 27% decrease in circulating irreversibly oxidised human non-mercaptalbumin-2 throughout treatment (p=0.046); 54% reduction in overall severity of endotoxaemia (p=0.024); delay in development of vasoplegia and acute lung injury; and delay in systemic activation of the TLR4 signalling pathway. Liver Dialysis Device-associated adverse clinical effects were not seen. The survival benefit and lack of adverse effects would support clinical trials of University College London-Liver Dialysis Device in acute liver failure patients. Copyright © 2015 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.
Large - scale Rectangular Ruler Automated Verification Device
NASA Astrophysics Data System (ADS)
Chen, Hao; Chang, Luping; Xing, Minjian; Xie, Xie
2018-03-01
This paper introduces a large-scale rectangular ruler automated verification device, which consists of photoelectric autocollimator and self-designed mechanical drive car and data automatic acquisition system. The design of mechanical structure part of the device refer to optical axis design, drive part, fixture device and wheel design. The design of control system of the device refer to hardware design and software design, and the hardware mainly uses singlechip system, and the software design is the process of the photoelectric autocollimator and the automatic data acquisition process. This devices can automated achieve vertical measurement data. The reliability of the device is verified by experimental comparison. The conclusion meets the requirement of the right angle test procedure.
Development of Automated Testing Tools for Traffic Control Signals and Devices
DOT National Transportation Integrated Search
2012-01-30
Through a coordinated effort among the electrical engineering research team of the Florida State University (FSU) and key Florida Department of Transportation (FDOT) personnel, an automated testing system for National Electrical Manufacturers Associa...
40 CFR 1043.41 - EIAPP certification process.
Code of Federal Regulations, 2014 CFR
2014-07-01
... test engine you provide must include appropriate manifolds, aftertreatment devices, electronic control... CONTROLS CONTROL OF NOX, SOX, AND PM EMISSIONS FROM MARINE ENGINES AND VESSELS SUBJECT TO THE MARPOL... application for an EIAPP certificate for each engine family. An EIAPP certificate is valid starting with the...
40 CFR 1043.41 - EIAPP certification process.
Code of Federal Regulations, 2010 CFR
2010-07-01
... test engine you provide must include appropriate manifolds, aftertreatment devices, electronic control... CONTROLS CONTROL OF NOX, SOX, AND PM EMISSIONS FROM MARINE ENGINES AND VESSELS SUBJECT TO THE MARPOL... application for an EIAPP certificate for each engine family. An EIAPP certificate is valid starting with the...
40 CFR 1043.41 - EIAPP certification process.
Code of Federal Regulations, 2012 CFR
2012-07-01
... test engine you provide must include appropriate manifolds, aftertreatment devices, electronic control... CONTROLS CONTROL OF NOX, SOX, AND PM EMISSIONS FROM MARINE ENGINES AND VESSELS SUBJECT TO THE MARPOL... application for an EIAPP certificate for each engine family. An EIAPP certificate is valid starting with the...
40 CFR 1043.41 - EIAPP certification process.
Code of Federal Regulations, 2013 CFR
2013-07-01
... test engine you provide must include appropriate manifolds, aftertreatment devices, electronic control... CONTROLS CONTROL OF NOX, SOX, AND PM EMISSIONS FROM MARINE ENGINES AND VESSELS SUBJECT TO THE MARPOL... application for an EIAPP certificate for each engine family. An EIAPP certificate is valid starting with the...
40 CFR 1043.41 - EIAPP certification process.
Code of Federal Regulations, 2011 CFR
2011-07-01
... test engine you provide must include appropriate manifolds, aftertreatment devices, electronic control... CONTROLS CONTROL OF NOX, SOX, AND PM EMISSIONS FROM MARINE ENGINES AND VESSELS SUBJECT TO THE MARPOL... application for an EIAPP certificate for each engine family. An EIAPP certificate is valid starting with the...
Intelligent walkers for the elderly: performance and safety testing of VA-PAMAID robotic walker.
Rentschler, Andrew J; Cooper, Rory A; Blasch, Bruce; Boninger, Michael L
2003-01-01
A walker that could help navigate and avoid collisions with obstacles could help reduce health costs and increase the quality of care and independence of thousands of people. This study evaluated the safety and performance of the Veterans Affairs Personal Adaptive Mobility Aid (VA-PAMAID). We performed engineering tests on the VA-PAMAID to determine safety factors, including stability, energy consumption, fatigue life, and sensor and control malfunctions. The VA-PAMAID traveled 10.9 km on a full charge and avoided obstacles while traveling at a speed of up to 1.2 m/s. No failures occurred during static stability, climatic, or fatigue testing. Some problems were encountered during obstacle climbing and sensor and control testing. The VA-PAMAID has good range, has adequate reaction time, and is structurally sound. Clinical trials are planned to compare the device to other low-technical adaptive mobility devices.
Nishimura, Hidekazu
2012-11-01
Several Japanese companies sell electrical devices advertised as effective in inactivating viruses and killing bacteria by releasing special materials, e.g., Plasmacluster ions, Nanoe particle and minus ions, into the air. These companies claim that their devices killed bacteria on plates in their own experiments. We tested device effectiveness using the same experiments from the Plasmacluster ioniser SHARP Co., Japan, the Nanoe generator Panasonic Co., Japan, and the Vion KING JIM Co., Japan, to test their advertising claims. Bactericidal ability on agar plate was tested, using Staphylococcus aureus, Pseudomonas aeruginosa, Bacillus cereus, and Enterococcus faecalis as follows: the medium containing a certain amount of each bacterium was put onto an agar plate and smeared. Plates were kept in a closed chamber (inner volume 14.4 m3) or a glove box (inner volume 0.2 m), with one of the devices run for 2 hours. Plates not exposed to any device were used as controls. Each plate was retrieved and put in an incubator to count the number of bacterial colonies formed on the plate. There was no significant difference in the number of colonies on plates exposed to devices compared to control, in the number for all devices, or in all bacteria tested in experiments in the 14.4 m3 chamber. These results strongly suggest that these devices have almost no bactericidal effect, at least in space exceeding this volume. Colony formation was suppressed in the glove box in all devices and in all bacteria tested except P. aeruginosa, although the degree of suppression differed among experiments. The colony formation suppression mechanism was analyzed, and indicated that:colony formation did not change even after the removal of Plasmacluster ions, Nanoe particles, or negative ions from the air, while colony formation was decreased drastically by the removal of ozone from space, which was revealed to be generated inevitably during device operation. These results strongly suggest that the bactericidal effect seen only on the agar plate in narrow space was explained by ozone released in space as a by-product, not by special materials as advertising claimed. It is thus important to analyze the effect of special materials such as those done in this study and to suggest the involvement of ozone as the true cause, as have been done in this study, in evaluating bactericidal effect or viral inactivation as advertised by these companies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shao, Guocheng; Lu, Donglai; Fu, Zhifeng
This paper describes the design, fabrication, and testing of a pneumatically controlled,renewable, microfluidic device for conducting bead-based assays in an automated sequential injection analysis system. The device used a “brick wall”-like pillar array (pillar size: 20 μm length X 50 μm width X 45 μm height) with 5 μm gaps between the pillars serving as the micro filter. The flow channel where bead trapping occurred is 500 μm wide X 75 μm deep. An elastomeric membrane and an air chamber were located underneath the flow channel. By applying pressure to the air chamber, the membrane is deformed and pushed upwardmore » against the filter structure. This effectively traps beads larger than 5 μm and creates a “bed” or micro column of beads that can be perfused and washed with liquid samples and reagents. Upon completion of the assay process, the pressure is released and the beads are flushed out from underneath the filter structure to renew the device. Mouse IgG was used as a model analyte to test the feasibility of using the proposed device for immunoassay applications. Resulting microbeads from an on-chip fluorescent immunoassay were individually examined using flow cytometry. The results show that the fluorescence signal intensity distribution is fairly narrow indicating high chemical reaction uniformity among the beads population. Electrochemical onchip assay was also conducted. A detection limit of 0.1 ng/mL1 ppb was achieved and good device reliability and repeatability were demonstrated. The novel microfluidic-based beadstrapping device thus opens up a new pathway to design micro-bead based biosensor immunoassays for clinical and othervarious applications.« less
Golden Rays - March 2017 | Solar Research | NREL
, test and deploy a data enhanced hierarchical control architecture that adopts a hybrid approach to grid control. A centralized control layer will be complemented by distributed control algorithms for solar inverters and autonomous control of grid edge devices. The other NREL project will develop a novel control
Allen, Paul B; Salyer, Steven W; Dubick, Michael A; Holcomb, John B; Blackbourne, Lorne H
2010-07-01
The purpose of this study was to develop an in vitro torso model constructed with fluid bags and to determine whether this model could be used to differentiate between the heat prevention performance of devices with active chemical or radiant forced-air heating systems compared with passive heat loss prevention devices. We tested three active (Hypothermia Prevention Management Kit [HPMK], Ready-Heat, and Bair Hugger) and five passive (wool, space blankets, Blizzard blankets, human remains pouch, and Hot Pocket) hypothermia prevention products. Active warming devices included products with chemically or electrically heated systems. Both groups were tested on a fluid model warmed to 37 degrees C versus a control with no warming device. Core temperatures were recorded every 5 minutes for 120 minutes in total. Products that prevent heat loss with an actively heated element performed better than most passive prevention methods. The original HPMK achieved and maintained significantly higher temperatures than all other methods and the controls at 120 minutes (p < 0.05). None of the devices with an actively heated element achieved the sustained 44 degrees C that could damage human tissue if left in place for 6 hours. The best passive methods of heat loss prevention were the Hot Pocket and Blizzard blanket, which performed the same as two of the three active heating methods tested at 120 minutes. Our in vitro fluid bag "torso" model seemed sensitive to detect heat loss in the evaluation of several active or passive warming devices. All active and most passive devices were better than wool blankets. Under conditions near room temperature, passive warming methods (Blizzard blanket or the Hot Pocket) were as effective as active warming devices other than the original HPMK. Further studies are necessary to determine how these data can translate to field conditions in preventing heat loss in combat casualties.
Vibration reduction on automotive shafts using piezoceramics
NASA Astrophysics Data System (ADS)
Kunze, Holger; Riedel, Mathias; Schmidt, Knut; Bianchini, Emanuele
2003-08-01
This paper reports an experimental study on active vibration reduction for automotive shafts with the use of piezoelectric material. The work focuses on an axle of an Audi A2. The demand in the automobile sector for higher comfort in the vehicle is of a great importance alongside the requirements of lighter weight and low fuel consumption. These requirements are typically in conflict with each other. One solution is the use of intelligent materials instead of viscoelastic materials and proof mass absorbers. These solutions are quite heavy especially at low frequencies. Active vibration control and piezoelectric devices are advantageous in this application due to their low mass to performance ratio. Our research study explores the use of such piezoelectric devices for an axle. In conjunction with electronics it will reduce vibrations in the first natural bending mode of the axle. Laboratory tests simulated the condition present in the road. At first a stationary set up was used, then a simulated disturbance was input at the attachment points of the shaft. Finally, a test with rotating shaft was performed. Piezoelectric devices (custom QuickPacks from ACX, a Division of Cymer) were used as sensors and as actuators to properly control the axle during the different operating conditions. The power consumption of each actuator pair was less than 20W. The work described here details the test setup, the control strategy, the hardware implementation as well as the test results obtained.
Berzofsky, Ronald N.
1995-01-01
The observation that endotoxin caused gelation in extracts of Limulus amebocytes has been expanded to the development of an in vitro kinetic, quantitative chromogenic LAL assay (Kinetic-QCL) for the detection of endotoxin in aqueous fluids. Within the last 15 years, the use of Limulus amebocyte lysate to detect and control the presence of pyrogenic substances in pharmaceuticals and medical devices has gained wide international acceptance. Both the United States and European Pharmacopoeias contain descriptions of and requirements for the LAL Bacterial Endotoxin Test. Both pharmacopoeias have begun to remove the rabbit pyrogen test requirement in a majority of drug monographs and have substituted endotoxin limits to be determined by LAL. The use of LAL has proved invaluable in controlling the level of endotoxin in finished product. The endotoxin contribution of raw materials and packaging material can be monitored as well. In-process testing at critical production steps can identify additional sources of endotoxin contamination, and depyrogenation processes can be validated by quantitating the degradation of endotoxin challenges. The speed, reproducibility, sensitivity, and economics of the Kinetic-QCL assay, in conjunction with the ppropriate equipment and software, over both the in vivo rabbit pyrogen test and the more traditional LAL gel-clot assay allow a more in-depth approach to the control of endotoxin in pharmaceuticals and medical devices.
Maillot, Pauline; Dommes, Aurélie; Dang, Nguyen-Thong; Vienne, Fabrice
2017-02-01
A virtual-reality training program has been developed to help older pedestrians make safer street-crossing decisions in two-way traffic situations. The aim was to develop a small-scale affordable and transportable simulation device that allowed transferring effects to a full-scale device involving actual walking. 20 younger adults and 40 older participants first participated in a pre-test phase to assess their street crossings using both full-scale and small-scale simulation devices. Then, a trained older group (20 participants) completed two 1.5-h training sessions with the small-scale device, whereas an older control group received no training (19 participants). Thereafter, the 39 older trained and untrained participants took part in a 1.5-h post-test phase again with both devices. Pre-test phase results suggested significant differences between both devices in the group of older participants only. Unlike younger participants, older participants accepted more often to cross and had more collisions on the small-scale simulation device than on the full-scale one. Post-test phase results showed that training older participants on the small-scale device allowed a significant global decrease in the percentage of accepted crossings and collisions on both simulation devices. But specific improvements regarding the way participants took into account the speed of approaching cars and vehicles in the far lane were notable only on the full-scale simulation device. The findings suggest that the small-scale simulation device triggers a greater number of unsafe decisions compared to a full-scale one that allows actual crossings. But findings reveal that such a small-scale simulation device could be a good means to improve the safety of street-crossing decisions and behaviors among older pedestrians, suggesting a transfer of learning effect between the two simulation devices, from training people with a miniature device to measuring their specific progress with a full-scale one. Copyright © 2016 Elsevier Ltd. All rights reserved.
Usability of digital media in patients with COPD: a pilot study.
Cheung, Amy; Janssen, Anton; Amft, Oliver; Wouters, Emiel F M; Spruit, Martijn A
2013-04-01
Digital media can be integrated in tele-monitoring solutions, serving as the main interface between the patient and the caregiver. Consequently, the selection of the most appropriate digital medium for the specified target group is critical to ensure compliance with the tele-monitoring system. This pilot study aims to gather insights from patients with chronic obstructive pulmonary disease (COPD) on the ease-of-use, efficacy, effectiveness, and satisfaction of different types of digital media. Five off-the-shelf digital media devices were tested on nine patients at CIRO+ in Horn, The Netherlands. Usability was evaluated by asking patients to use each device to answer questions related to their symptoms and health status. Subsequently, patients completed a paper-based device usability questionnaire, which assessed prior experience with digital media, device dimensions, device controllability, response speed, screen readability, ease-of-use, and overall satisfaction. After testing all the devices, patients ranked the devices according to their preference. We identified the netbook as the preferred type of device due to its good controllability, fast response time, and large screen size. The smartphone was the least favorite device as patients found the size of the screen to be too small, which made it difficult to interact with. The pilot study has provided important insights to guide the selection of the most appropriate type of digital medium for implementation in tele-monitoring solutions for patients with COPD. As the digital medium is an important interface to the patient in tele-monitoring solutions, it is essential that patients feel motivated to interact with the digital medium on a regular basis.
NASA Astrophysics Data System (ADS)
Nikitczuk, Jason; Weinberg, Brian; Mavroidis, Constantinos
2006-03-01
In this paper we present the design and control algorithms for novel electro-rheological fluid based torque generation elements that will be used to drive the joint of a new type of portable and controllable Active Knee Rehabilitation Orthotic Device (AKROD) for gait retraining in stroke patients. The AKROD is composed of straps and rigid components for attachment to the leg, with a central hinge mechanism where a gear system is connected. The key features of AKROD include: a compact, lightweight design with highly tunable torque capabilities through a variable damper component, full portability with on board power, control circuitry, and sensors (encoder and torque), and real-time capabilities for closed loop computer control for optimizing gait retraining. The variable damper component is achieved through an electro-rheological fluid (ERF) element that connects to the output of the gear system. Using the electrically controlled rheological properties of ERFs, compact brakes capable of supplying high resistive and controllable torques, are developed. A preliminary prototype for AKROD v.2 has been developed and tested in our laboratory. AKROD's v.2 ERF resistive actuator was tested in laboratory experiments using our custom made ERF Testing Apparatus (ETA). ETA provides a computer controlled environment to test ERF brakes and actuators in various conditions and scenarios including emulating the interaction between human muscles involved with the knee and AKROD's ERF actuators / brakes. In our preliminary results, AKROD's ERF resistive actuator was tested in closed loop torque control experiments. A hybrid (non-linear, adaptive) Proportional-Integral (PI) torque controller was implemented to achieve this goal.
Thermoplastic fusion bonding using a pressure-assisted boiling point control system.
Park, Taehyun; Song, In-Hyouk; Park, Daniel S; You, Byoung Hee; Murphy, Michael C
2012-08-21
A novel thermoplastic fusion bonding method using a pressure-assisted boiling point (PABP) control system was developed to apply precise temperatures and pressures during bonding. Hot embossed polymethyl methacrylate (PMMA) components containing microchannels were sealed using the PABP system. Very low aspect ratio structures (AR = 1/100, 10 μm in depth and 1000 μm in width) were successfully sealed without collapse or deformation. The integrity and strength of the bonds on the sealed PMMA devices were evaluated using leakage and rupture tests; no leaks were detected and failure during the rupture tests occurred at pressures greater than 496 kPa. The PABP system was used to seal 3D shaped flexible PMMA devices successfully.
Optoelectronic date acquisition system based on FPGA
NASA Astrophysics Data System (ADS)
Li, Xin; Liu, Chunyang; Song, De; Tong, Zhiguo; Liu, Xiangqing
2015-11-01
An optoelectronic date acquisition system is designed based on FPGA. FPGA chip that is EP1C3T144C8 of Cyclone devices from Altera corporation is used as the centre of logic control, XTP2046 chip is used as A/D converter, host computer that communicates with the date acquisition system through RS-232 serial communication interface are used as display device and photo resistance is used as photo sensor. We use Verilog HDL to write logic control code about FPGA. It is proved that timing sequence is correct through the simulation of ModelSim. Test results indicate that this system meets the design requirement, has fast response and stable operation by actual hardware circuit test.
Testing and performance of a new friction damper for seismic vibration control
NASA Astrophysics Data System (ADS)
Martínez, Carlos A.; Curadelli, Oscar
2017-07-01
In the last two decades, great efforts were carried out to reduce the seismic demand on structures through the concept of energy dissipation instead of increasing the stiffness and strength. Several devices based on different energy dissipation principles have been developed and implemented worldwide, however, most of the dissipation devices are usually installed using diagonal braces, which entail certain drawbacks on apertures for circulation, lighting or ventilation and architectural or functional requirements often preclude this type of installations. In this work, a conceptual development of a novel energy dissipation device, called Multiple Friction Damper (MFD), is proposed and examined. To verify its characteristics and performance, the MFD was implemented on a single storey steel frame experimental model and tested under different conditions of normal force and real time acceleration records. Experimental results demonstrated that the new MFD constitutes an effective and reliable alternative to control the structural response in terms of displacement and acceleration. A mathematical formulation based on the Wen's model reflecting the nonlinear behaviour of the device is also presented.
46 CFR 160.064-6 - Examinations, tests and inspections.
Code of Federal Regulations, 2010 CFR
2010-10-01
... labeled water safety buoyant devices shall maintain quality control of the materials used, manufacturing... available to the recognized laboratory inspector or to the Coast Guard marine inspector, or both, for review upon request. (b) Laboratory inspections and tests. Such examinations, inspections and tests as are...
An electronic circuit for sensing malfunctions in test instrumentation
NASA Technical Reports Server (NTRS)
Miller, W. M., Jr.
1969-01-01
Monitoring device differentiates between malfunctions occurring in the system undergoing test and malfunctions within the test instrumentation itself. Electronic circuits in the monitor use transistors to commutate silicon controlled rectifiers by removing the drive voltage, display circuits are then used to monitor multiple discrete lines.
Kim, Seon Young; Kim, Hyunjin; Park, Yeongchun; Lim, Jinsook; Kim, Jimyung; Koo, Sun Hoe; Kwon, Gye Cheol
2017-06-01
On-site drugs of abuse testing devices have undergone continuous improvement. We evaluated three devices with different designs: an automated reader, the Multi-Drug Screen Test Device with DxLINK (DxLINK; Innovacon, Alere, San Diego, USA) and two colorimetric immunoassays, the One Step Multi-Line Screen Panel with Integrated E-Z Split Key Cup II (E-Z Cup; Innovacon, Alere) and the One Step Multi-Drug Screen Panel card (Multi4 card; Alere, Abon Biopharm, Hangzhou, China). Eleven drugs [amphetamine, secobarbital, oxazepam, buprenorphine, benzoylecgonine, methylenedioxymethamphetamine (MDMA), 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THC), methamphetamine, methadone, morphine and nortriptyline] were tested using the DxLINK and E-Z Cup. Four drugs (benzoylecgonine, THC, methamphetamine and morphine) were tested using the Multi4 card using control materials (Detectabuse Stat-Skreen; Biochemical Diagnostics, Edgewood, NY, USA). The concentrations (-50%, -25%, +25%, +50% and 3× cut-off values) of the control materials were confirmed by mass spectrometry. Concordance rates were calculated around cut-offs. All devices showed high overall agreement rates of >90% with a few exceptions: the DxLINK exhibited lower sensitivity for benzoylecgonine, methadone and nortriptyline (60% and 30%, 92% and 40%, and 96% and 60% sensitivity at +50% and +25% cut-off levels, respectively). The E-Z Cup exhibited lower sensitivity for oxazepam and nortriptyline (97% and 50%, and 97% and 40% sensitivity at +50% and +25% cut-off levels, respectively). We additionally evaluated test-band color by visual inspection using a standard color-scale card. When detailed color criteria for determination of positivity were applied for the E-Z Cup, using slightly less stringent criteria, oxazepam, buprenorphine, MDMA and nortriptyline showed increases in sensitivity from 70-80% to 90-100%, all with a specificity above 98%. Overall, all devices exhibited satisfactory performance at ±50% cut-off levels for commonly used drugs, with the exception of lower sensitivity for cocaine testing for DxLINK. Careful evaluation of devices and elaborate calibration of visual interpretation for determining positivity may help improve the performance of these devices. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Reno, Frederick E; Edwards, C Nicholas; Bendix Jensen, Morten; Török-Bathó, Magdolna; Esdaile, David J; Piché, Claude; Triest, Myriam; Carballo, Dolorès
2016-09-01
The intranasal route is a promising route of administration for several emergency rescue drugs including naloxone and glucagon. Glucagon nasal powder (GNP) is a novel, needle-free delivery system for intranasal administration of glucagon for the treatment of severe hypoglycemia, an infrequent but serious complication of insulin use in patients with diabetes. The GNP delivery device is a compact, highly portable, single-use nasal powder dosing device constructed of polypropylene that allows for simple, single-step administration. To evaluate the toxicological profile of the polypropylene resin used in the actuator part of the delivery device that will contact skin and nasal mucosal membranes of the patient, we performed an in vitro cytotoxicity study, a skin sensitization study and an irritation (intracutaneous reactivity) study in animal models. Extracts of the actuator of the GNP device were generated from HAM F12 medium with 10% fetal bovine serum, 0.9% sodium chloride (NaCl) or sesame oil. The in vitro cytotoxicity test was performed in cultured L929 mouse fibroblasts. Skin sensitization analysis was performed in 10 guinea pigs according to the Magnusson-Kligman method, using a maximization method with Freund's Complete Adjuvant. Irritation following intracutaneous/intradermal treatment with device extracts (NaCl and sesame oil extractants) was assessed in three New Zealand White rabbits. In vitro cytotoxicity test: Both undiluted and diluted extract showed no toxicity (i.e. no abnormal morphology, cell death or cell lysis) toward L929 fibroblasts (cytotoxicity grade 0). Sensitization test in guinea pigs: Challenge with device extracts did not evoke positive responses in test animals previously induced with device extracts. The net response value represented an incidence rate of 0% and a net dermal irritation score value of 0.00. Irritation (intracutaneous/intradermal) test in New Zealand White rabbits: Device extracts and corresponding vehicle controls caused similar irritation reactions. The difference between the mean scores for the device extracts and the corresponding vehicle controls was less than 1.0. Extracts of the polypropylene resin of the GNP delivery device are not cytotoxic, do not result in dermal sensitization and do not cause irritation when applied topically or intracutaneously. Given the infrequent use and very short duration of exposure to the nasal mucosa during administration of GNP, the polypropylene resin of the GNP device actuator will likely not cause adverse dermal sensitization effects or irritation effects in humans and can, therefore, be considered for use as a delivery device in clinical trials assessing the efficacy and safety of GNP for the treatment of insulin-using patients experiencing episodes of severe hypoglycemia.
Evaluation of Motor Control Using Haptic Device
NASA Astrophysics Data System (ADS)
Nuruki, Atsuo; Kawabata, Takuro; Shimozono, Tomoyuki; Yamada, Masafumi; Yunokuchi, Kazutomo
When the kinesthesia and the touch act at the same time, such perception is called haptic perception. This sense has the key role in motor information on the force and position control. The haptic perception is important in the field where the evaluation of the motor control is needed. The purpose of this paper is to evaluate the motor control, perception of heaviness and distance in normal and fatigue conditions using psychophysical experiment. We used a haptic device in order to generate precise force and distance, but the precedent of the evaluation system with the haptic device has been few. Therefore, it is another purpose to examine whether the haptic device is useful as evaluation system for the motor control. The psychophysical quantity of force and distance was measured by two kinds of experiments. Eight healthy subjects participated in this study. The stimulation was presented by haptic device [PHANTOM Omni: SensAble Company]. The subjects compared between standard and test stimulation, and answered it had felt which stimulation was strong. In the result of the psychophysical quantity of force, just noticeable difference (JND) had a significant difference, and point of subjective equality (PSE) was not different between normal and muscle fatigue. On the other hand, in the result of the psychophysical quantity of distance, JND and PSE were not difference between normal and muscle fatigue. These results show that control of force was influenced, but control of distance was not influenced in muscle fatigue. Moreover, these results suggested that the haptic device is useful as the evaluation system for the motor control.
46 CFR 160.062-4 - Inspections and tests.
Code of Federal Regulations, 2013 CFR
2013-10-01
... required under § 160.062-3(b) while the device is submerged in water or in a water-filled pressure testing... manual control as a result of the low temperature exposure. (iii) Corrosion resisting test. After the completion of its temperature test, a hydraulic release sample shall be exposed to a 20 percent salt spray...
46 CFR 160.062-4 - Inspections and tests.
Code of Federal Regulations, 2014 CFR
2014-10-01
... required under § 160.062-3(b) while the device is submerged in water or in a water-filled pressure testing... manual control as a result of the low temperature exposure. (iii) Corrosion resisting test. After the completion of its temperature test, a hydraulic release sample shall be exposed to a 20 percent salt spray...
46 CFR 160.062-4 - Inspections and tests.
Code of Federal Regulations, 2012 CFR
2012-10-01
... required under § 160.062-3(b) while the device is submerged in water or in a water-filled pressure testing... manual control as a result of the low temperature exposure. (iii) Corrosion resisting test. After the completion of its temperature test, a hydraulic release sample shall be exposed to a 20 percent salt spray...
46 CFR 160.062-4 - Inspections and tests.
Code of Federal Regulations, 2011 CFR
2011-10-01
... required under § 160.062-3(b) while the device is submerged in water or in a water-filled pressure testing... manual control as a result of the low temperature exposure. (iii) Corrosion resisting test. After the completion of its temperature test, a hydraulic release sample shall be exposed to a 20 percent salt spray...
A Novel Disintegration Tester for Solid Dosage Forms Enabling Adjustable Hydrodynamics.
Kindgen, Sarah; Rach, Regine; Nawroth, Thomas; Abrahamsson, Bertil; Langguth, Peter
2016-08-01
A modified in vitro disintegration test device was designed that enables the investigation of the influence of hydrodynamic conditions on disintegration of solid oral dosage forms. The device represents an improved derivative of the compendial PhEur/USP disintegration test device. By the application of a computerized numerical control, a variety of physiologically relevant moving velocities and profiles can be applied. With the help of computational fluid dynamics, the hydrodynamic and mechanical forces present in the probe chamber were characterized for a variety of device moving speeds. Furthermore, a proof of concept study aimed at the investigation of the influence of hydrodynamic conditions on disintegration times of immediate release tablets. The experiments demonstrated the relevance of hydrodynamics for tablet disintegration, especially in media simulating the fasted state. Disintegration times increased with decreasing moving velocity. A correlation between experimentally determined disintegration times and computational fluid dynamics predicted shear stress on tablet surface was established. In conclusion, the modified disintegration test device is a valuable tool for biorelevant in vitro disintegration testing of solid oral dosage forms. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
NIR camera and spectrograph SWIMS for TAO 6.5m telescope: array control system and its performance
NASA Astrophysics Data System (ADS)
Terao, Yasunori; Motohara, Kentaro; Konishi, Masahiro; Takahashi, Hidenori; Kato, Natsuko M.; Kitagawa, Yutaro; Kobayakawa, Yutaka; Ohashi, Hirofumi; Tateuchi, Ken; Todo, Soya
2016-08-01
SWIMS (Simultaneous-color Wide-field Infrared Multi-object Spectrograph) is a near-infrared imager and multi-object spectrograph as one of the first generation instruments for the University of Tokyo Atacama Observatory (TAO) 6.5m telescope. In this paper, we describe an array control system of SWIMS and results of detector noise performance evaluation. SWIMS incorporates four (and eight in future) HAWAII-2RG focal plane arrays for detectors, each driven by readout electronics components: a SIDECAR ASIC and a JADE2 Card. The readout components are controlled by a HAWAII-2RG Testing Software running on a virtual Windows machine on a Linux PC called array control PC. All of those array control PCs are then supervised by a SWIMS control PC. We have developed an "array control software system", which runs on the array control PC to control the HAWAII-2RG Testing Software, and consists of a socket client and a dedicated server called device manager. The client runs on the SWIMS control PC, and the device manager runs on the array control PC. An exposure command, issued by the client on the SWIMS control PC, is sent to the multiple device managers on the array control PCs, and then multiple HAWAII-2RGs are driven simultaneously. Using this system, we evaluate readout noise performances of the detectors, both in a test dewar and in a SWIMS main dewar. In the test dewar, we confirm the readout noise to be 4.3 e- r.m.s. by 32 times multiple sampling when we operate only a single HAWAII-2RG, whereas in the case of simultaneous driving of two HAWAII-2RGs, we still obtain sufficiently low readout noise of 10 e- r.m.s. In the SWIMS main dewar, although there are some differences between the detectors, the readout noise is measured to be 4:1-4:6 e- r.m.s. with simultaneous driving by 64 times multiple sampling, which meets the requirement for background-limited observations in J band of 14 e- r.m.s..
Clarke, C; Andrews, S P
2014-12-01
An experimental study was made of the potential of the TASER-X26™ law enforcement electronic control device to ignite petrol vapours if used by an officer to incapacitate a person soaked in petrol, or within a flammable atmosphere containing petrol vapour. Bench scale tests have shown that a wooden mannequin with pig skin covering the chest was a suitable representation of a human target. Full scale tests using the mannequin have shown that the arc from a TASER-X26™ is capable of igniting petrol/air vapours on a petrol-soaked person. Further tests in a 1/5 scale and a full scale compartment have shown that if a TASER is used within a compartment, a petrol vapour explosion (deflagration) may be achieved. It is evident from this research that if used in a flammable vapour rich environment, the device could prove fatal not only to the target but the TASER® operator as well. Copyright © 2014 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.
2010-10-01
4 8 4 | A Publication of the Defense Acquisition University http://www.dau.mil image designed by Miracle Riese » Keywords: Acceleration Test...Std Z39-18 4 8 6 | A Publication of the Defense Acquisition University http://www.dau.mil Generally speaking, medical devices are designed to...However, because the devices are designed for a controlled environment, concerns they may adversely affect the operation of aircraft systems must be
Whisson, Desley A.; Takekawa, John Y.
2000-01-01
Aquatic hazing devices recently have been developed as a possible means of deterring waterbirds from oil spills, thereby reducing casualties. However, the effectiveness of these devices has not been examined with rigorous statistical tests. We conducted a study in the San Francisco Bay estuary to develop a design for testing the effectiveness of an aquatic hazing device on waterbirds in open water. Transects marked with poles at 100-m inter- vals up to 800 m from the hazing device were established at two sites separated by three km in the north bay. Alter- nating two-day test and control periods were conducted at each site. Observers in over-water blinds counted the number, species and behavior (swimming, diving, or preening) of birds on transects each day. Aerial surveys of birds within four km of the device were conducted at the beginning of each test. For both aerial and ground surveys, a three-way mixed model analysis of variance test was used to examine trial, distance from the device, and treatment (device on or off) fixed effects, and site as a random effect on numbers of Greater and Lesser scaup (Aythya affinis and A. marila), Surf Scoter (Melanitta perspicillata), and all other waterbirds. We could not detect a significant deter- rent effect of the hazing device in either aerial surveys of all ducks or scaup (all ducks, F,283 = 1.1; Scaup, F28,230 = 0.9, all n.s.; 3-factor ANOVA), or ground surveys for all ducks or scaup (all ducks, F28,23 = 1.0; scaup, F2s,230 = 0.9, all n.s.; 3-factor ANOVA). There was a significant trial-by-treatment interaction for Surf Scoters (F4,9 = 5.4, P = 0.02; 3-factor ANOVA), but Surf Scoter numbers fluctuated greatly among trials so the effect of the device on this species was not clear. Birds did not alter their behavior when the device was active. In general, although aquatic hazing devices have potential to reduce waterbird mortality in oil spills, the tested device was not effective as a deterrent for waterfowl in experimental trials on the estuary. Received 27 September 1999, accepted 3January 2000.
40 CFR 60.1360 - What records must I keep for stack tests?
Code of Federal Regulations, 2010 CFR
2010-07-01
... measure specified in table 1 of this subpart: (1) Dioxins/furans. (2) Cadmium. (3) Lead. (4) Mercury. (5... control device during all stack tests for dioxins/furans emissions. (d) The calendar date of each record. ...
Elnady, Ahmed Mohamed; Zhang, Xin; Xiao, Zhen Gang; Yong, Xinyi; Randhawa, Bubblepreet Kaur; Boyd, Lara; Menon, Carlo
2015-01-01
Traditional, hospital-based stroke rehabilitation can be labor-intensive and expensive. Furthermore, outcomes from rehabilitation are inconsistent across individuals and recovery is hard to predict. Given these uncertainties, numerous technological approaches have been tested in an effort to improve rehabilitation outcomes and reduce the cost of stroke rehabilitation. These techniques include brain-computer interface (BCI), robotic exoskeletons, functional electrical stimulation (FES), and proprioceptive feedback. However, to the best of our knowledge, no studies have combined all these approaches into a rehabilitation platform that facilitates goal-directed motor movements. Therefore, in this paper, we combined all these technologies to test the feasibility of using a BCI-driven exoskeleton with FES (robotic training device) to facilitate motor task completion among individuals with stroke. The robotic training device operated to assist a pre-defined goal-directed motor task. Because it is hard to predict who can utilize this type of technology, we considered whether the ability to adapt skilled movements with proprioceptive feedback would predict who could learn to control a BCI-driven robotic device. To accomplish this aim, we developed a motor task that requires proprioception for completion to assess motor-proprioception ability. Next, we tested the feasibility of robotic training system in individuals with chronic stroke (n = 9) and found that the training device was well tolerated by all the participants. Ability on the motor-proprioception task did not predict the time to completion of the BCI-driven task. Both participants who could accurately target (n = 6) and those who could not (n = 3), were able to learn to control the BCI device, with each BCI trial lasting on average 2.47 min. Our results showed that the participants' ability to use proprioception to control motor output did not affect their ability to use the BCI-driven exoskeleton with FES. Based on our preliminary results, we show that our robotic training device has potential for use as therapy for a broad range of individuals with stroke.
Elnady, Ahmed Mohamed; Zhang, Xin; Xiao, Zhen Gang; Yong, Xinyi; Randhawa, Bubblepreet Kaur; Boyd, Lara; Menon, Carlo
2015-01-01
Traditional, hospital-based stroke rehabilitation can be labor-intensive and expensive. Furthermore, outcomes from rehabilitation are inconsistent across individuals and recovery is hard to predict. Given these uncertainties, numerous technological approaches have been tested in an effort to improve rehabilitation outcomes and reduce the cost of stroke rehabilitation. These techniques include brain–computer interface (BCI), robotic exoskeletons, functional electrical stimulation (FES), and proprioceptive feedback. However, to the best of our knowledge, no studies have combined all these approaches into a rehabilitation platform that facilitates goal-directed motor movements. Therefore, in this paper, we combined all these technologies to test the feasibility of using a BCI-driven exoskeleton with FES (robotic training device) to facilitate motor task completion among individuals with stroke. The robotic training device operated to assist a pre-defined goal-directed motor task. Because it is hard to predict who can utilize this type of technology, we considered whether the ability to adapt skilled movements with proprioceptive feedback would predict who could learn to control a BCI-driven robotic device. To accomplish this aim, we developed a motor task that requires proprioception for completion to assess motor-proprioception ability. Next, we tested the feasibility of robotic training system in individuals with chronic stroke (n = 9) and found that the training device was well tolerated by all the participants. Ability on the motor-proprioception task did not predict the time to completion of the BCI-driven task. Both participants who could accurately target (n = 6) and those who could not (n = 3), were able to learn to control the BCI device, with each BCI trial lasting on average 2.47 min. Our results showed that the participants’ ability to use proprioception to control motor output did not affect their ability to use the BCI-driven exoskeleton with FES. Based on our preliminary results, we show that our robotic training device has potential for use as therapy for a broad range of individuals with stroke. PMID:25870554
NASA Astrophysics Data System (ADS)
Denn, Michael E.
Several recent studies have shown the advantages of active and/or passive flow control devices for boundary layer flow modification. Many current and future proposed air vehicles have very short or offset diffusers in order to save vehicle weight and create more optimal vehicle/engine integration. Such short coupled diffusers generally result in boundary layer separation and loss of pressure recovery which reduces engine performance and in some cases may cause engine stall. Deployment of flow control devices can alleviate this problem to a large extent; however, almost all active flow control devices have some energy penalty associated with their inclusion. One potential low penalty approach for enhancing the diffuser performance is to combine the passive flow control elements such as micro-ramps with active flow control devices such as synthetic jets to achieve higher control authority. The goal of this dissertation is twofold. The first objective is to assess the ability of CFD with URANS turbulence models to accurately capture the effects of the synthetic jets and micro-ramps on boundary layer flow. This is accomplished by performing numerical simulations replicating several experimental test cases conducted at Georgia Institute of Technology under the NASA funded Inlet Flow Control and Prediction Technologies Program, and comparing the simulation results with experimental data. The second objective is to run an expanded CFD matrix of numerical simulations by varying various geometric and other flow control parameters of micro-ramps and synthetic jets to determine how passive and active control devices interact with each other in increasing and/or decreasing the control authority and determine their influence on modification of boundary layer flow. The boundary layer shape factor is used as a figure of merit for determining the boundary layer flow quality/modification and its tendency towards separation. It is found by a large number of numerical experiments and the analysis of simulation data that a flow control device's influence on boundary layer quality is a function of three factors: (1) the strength of the longitudinal vortex emanating from the flow control device or devices, (2) the height of the vortex core above the surface and, when a synthetic jet is present, (3) the momentum added to the boundary layer flow.
Variable Emittance Electrochromic Devices for Satellite Thermal Control
NASA Astrophysics Data System (ADS)
Demiryont, Hulya; Shannon, Kenneth C.
2007-01-01
An all-solid-state electrochromic device (ECD) was designed for electronic variable emissivity (VE) control. In this paper, a low weight (5g/m2) electrochromic thermal control device, the EclipseVEECD™, is detailed as a viable thermal control system for spacecraft outer surface temperatures. Discussion includes the technology's performance, satellite applications, and preparations for space based testing. This EclipseVEECD™ system comprises substrate/mirror electrode/active element/IR transparent electrode layers. This system tunes and modulates reflection/emittance from 5 μm to 15 μm region. Average reflectance/emittance modulation of the system from the 400 K to 250 K region is about 75%, while at room temperature (9.5 micron) reflectance/emittance is around 90%. Activation voltage of the EclipseVEECD™ is around ±1 Volt. The EclipseVEECD™ can be used as a smart thermal modulator for the thermal control of satellites and spacecraft by monitoring and adjusting the amount of energy emitted from the outer surfaces. The functionality of the EclipseVEECD™ was successfully demonstrated in vacuum using a multi-purpose heat dissipation/absorption test module, the EclipseHEAT™. The EclipseHEAT™ has been successfully flight checked and integrated onto the United States Naval Alchemy MidSTAR satellite, scheduled to launch December 2006.
Validation Tests of a Non-Nuclear Combined Asphalt and Soil Density Gauge
2014-04-01
limit if applicable. This approach was considered as if this device was to be used on a construction project for quality control where the material...military contingency construction activities, because they are not sufficiently accurate compared to the NDG for quality control use in permanent...binder. Nominal asphalt content with water included was 5.2. m Average results from producer’s Quality Control (QC) testing. The list of instruments
Application of Micro-ramp Flow Control Devices to an Oblique Shock Interaction
NASA Technical Reports Server (NTRS)
Hirt, Stefanie; Anderson, Bernhard
2007-01-01
Tests are planned in the 15cm x 15cm supersonic wind tunnel at NASA Glenn to demonstrate the applicability of micro-ramp flow control to the management of shock wave boundary layer interactions. These tests will be used as a database for computational fluid dynamics (CFD) validation and Design of Experiments (DoE) design information. Micro-ramps show potential for mechanically simple and fail-safe boundary layer control.
2005-09-01
of a system to store and retrieve digital/ wireless communication information from a pacemaker/ defibrillator, or other device , and to alert medical... wireless communication information from a pacemaker/defibrillator, or other device , and to alert medical personnel when a person is experiencing...with heart, pacing, program, test, sensor , circuit) where the individual needs immediate attention an audible alert will go off at the nurse’s
Nonlinear Properties in Langasite Isomorphs for Advanced Frequency Control Devices and Clocks
2006-11-01
or LGN), and langatate (La3Ga5.5Ta0.5O14 or LGT), have emerged as new materials to replace quartz in advanced frequency control devices and clocks...application and of angle Ψ. Fig. 1. Langatate boule (photo courtesy of the Univ. Central Florida) and typical resonators for testing. Table 1...langanite and y-cut langatate ,” IEEE Tr. Ultrason. Ferroelec. Freq. Contr., pp. 1678-1682, 2003. Kim, Y., “Amplitude-frequency effect of Y-cut langanite
Rollator use and functional outcome of geriatric rehabilitation.
Vogt, Lutz; Lucki, Katrin; Bach, Matthias; Banzer, Winfried
2010-01-01
In a quasi-experimental pre- and postdesign, we examined the effect of rollator use on functional rehabilitation outcome in geriatric patients.From a sample of 458 geriatric inpatients, we matched 30 subjects who were not using assistive devices in their everyday lives but received a wheeled walker at the time of hospital admission (first-time user group) according to their admission scores on three motor performance tests (Timed Up-and-Go, Five-Times-Sit-to-Stand, and Performance-Oriented Mobility Assessment -Balance) with 30 patients who were actively using rollators as their primary walking aid for at least 3 months (long-term user group) and 30 control subjects without walking-aid assistance. Measurements were repeated after the inpatient rehabilitation regimen.The Kruskal-Wallis test did not reveal significant group differences in rehabilitation progress. Controls and device users, regardless of walking-aid experience, demonstrated nearly comparable mobility, strength, and balance improvements. More than half of each cohort (controls, n = 22; first-time, n = 17; long-term, n = 18) achieved functional gains in all three motor tests.The study showed that rollator assistance does not interfere with rehabilitation outcome and, to some extent, legitimates the prescription of assistive devices to improve confidence and restore or maintain motor ability at the highest possible level.
Jiang, Xi; Zhang, Yu; Chen, Bo; Lin, Ye
2017-04-01
Extraction socket remodeling and ridge preservation strategies have been extensively explored. To evaluate the efficacy of applying a micro-titanium stent as a pressure bearing device on extraction socket remodeling of maxillary anterior tooth. Twenty-four patients with a extraction socket of maxillary incisor were treated with spontaneous healing (control group) or by applying a micro-titanium stent as a facial pressure bearing device over the facial bone wall (test group). Two virtual models obtained from cone beam computed tomography data before extraction and 4 months after healing were 3-dimenionally superimposed. Facial bone wall resorption, extraction socket remodeling features and ridge width preservation rate were determined and compared between the groups. Thin facial bone wall resulted in marked resorption in both groups. The greatest palatal shifting distance of facial bone located at the coronal level in the control group, but middle level in the test group. Compared with the original extraction socket, 87.61 ± 5.88% ridge width was preserved in the test group and 55.09 ± 14.46% in the control group. Due to the facial pressure bearing property, the rigid micro-titanium stent might preserve the ridge width and alter the resorption features of extraction socket. © 2016 Wiley Periodicals, Inc.
Automated longwall guidance and control vertical control subsystem, volume 1
NASA Technical Reports Server (NTRS)
Griffiths, W. R.; Smirlock, M.; Aplin, J.; Fish, R. B.; Fish, D.
1982-01-01
A design, fabrication, and implementation of a horizon control of a longwall shearer was performed. This equipment was tested and demonstrated aboveground. This hardware was also installed on a longwall face. The feasibility of providing horizon control for a shearer was demonstrated aboveground. The feasibility of retrofitting the necessary sensors in a survivable manner was demonstrated underground. Subsequent field tests of a specific component, the natural background sensor, at a western location demonstrated the particular usefulness of this device on a wider application basis.
LQC control for the Mini-Mast experiment
NASA Technical Reports Server (NTRS)
Montgomery, R. C.; Ghosh, D.
1988-01-01
The Mini-Mast system is briefly reviewed, and results of a simulation study of the LQG control for the Mini-Mast experiment are reported. In particular, attention is given to problems and limitations related to the testing of control laws using reaction mass actuators, such as accounting for force and stroke limits of these devices. The local controller used in the study and the algorithm for converting the force commands of the LQG algorithm to position commands for the reaction mass device are described. It is shown that the LQG generated damping is reduced when a local controller is used and the position command is not saturated; it drops still further when the position command is saturated.
[Feasibility Study on Digital Signal Processor and Gear Pump of Uroflowmeter Calibration Device].
Yuan, Qing; Ji, Jun; Gao, Jiashuo; Wang, Lixin; Xiao, Hong
2016-08-01
It will cause hidden trouble on clinical application if the uroflowmeter is out of control.This paper introduces a scheme of uroflowmeter calibration device based on digital signal processor(DSP)and gear pump and shows studies of its feasibility.According to the research plan,we analyzed its stability,repeatability and linearity by building a testing system and carried out experiments on it.The flow test system is composed of DSP,gear pump and other components.The test results showed that the system could produce a stable water flow with high precision of repeated measurement and different flow rate.The test system can calibrate the urine flow rate well within the range of 9~50mL/s which has clinical significance,and the flow error is less than 1%,which meets the technical requirements of the calibration apparatus.The research scheme of uroflowmeter calibration device on DSP and gear pump is feasible.
40 CFR 65.164 - Performance test and flare compliance determination notifications and reports.
Code of Federal Regulations, 2010 CFR
2010-07-01
... PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas System or a Process § 65.164 Performance test and flare... complete test report shall include a brief process description, sampling site description, description of...
40 CFR 63.6120 - What performance tests and other procedures must I use?
Code of Federal Regulations, 2012 CFR
2012-07-01
... parameters associated with operation of the stationary combustion turbine and any emission control device... Turbines Testing and Initial Compliance Requirements § 63.6120 What performance tests and other procedures.... (e) If your stationary combustion turbine is not equipped with an oxidation catalyst, you must...
40 CFR 63.6120 - What performance tests and other procedures must I use?
Code of Federal Regulations, 2013 CFR
2013-07-01
... parameters associated with operation of the stationary combustion turbine and any emission control device... Turbines Testing and Initial Compliance Requirements § 63.6120 What performance tests and other procedures.... (e) If your stationary combustion turbine is not equipped with an oxidation catalyst, you must...
40 CFR 63.6120 - What performance tests and other procedures must I use?
Code of Federal Regulations, 2014 CFR
2014-07-01
... parameters associated with operation of the stationary combustion turbine and any emission control device... Turbines Testing and Initial Compliance Requirements § 63.6120 What performance tests and other procedures.... (e) If your stationary combustion turbine is not equipped with an oxidation catalyst, you must...
40 CFR 63.10898 - What are my performance test requirements?
Code of Federal Regulations, 2012 CFR
2012-07-01
.... (3) If you have an electric induction furnace equipped with an emissions control device at an existing foundry, you may use the test results from another electric induction furnace to demonstrate... induction furnace at an existing foundry, you may use the test results from another electric induction...
40 CFR 63.10898 - What are my performance test requirements?
Code of Federal Regulations, 2013 CFR
2013-07-01
.... (3) If you have an electric induction furnace equipped with an emissions control device at an existing foundry, you may use the test results from another electric induction furnace to demonstrate... induction furnace at an existing foundry, you may use the test results from another electric induction...
40 CFR 63.10898 - What are my performance test requirements?
Code of Federal Regulations, 2014 CFR
2014-07-01
.... (3) If you have an electric induction furnace equipped with an emissions control device at an existing foundry, you may use the test results from another electric induction furnace to demonstrate... induction furnace at an existing foundry, you may use the test results from another electric induction...
40 CFR 63.10898 - What are my performance test requirements?
Code of Federal Regulations, 2010 CFR
2010-07-01
.... (3) If you have an electric induction furnace equipped with an emissions control device at an existing foundry, you may use the test results from another electric induction furnace to demonstrate... induction furnace at an existing foundry, you may use the test results from another electric induction...
40 CFR 63.10898 - What are my performance test requirements?
Code of Federal Regulations, 2011 CFR
2011-07-01
.... (3) If you have an electric induction furnace equipped with an emissions control device at an existing foundry, you may use the test results from another electric induction furnace to demonstrate... induction furnace at an existing foundry, you may use the test results from another electric induction...
40 CFR 53.3 - General requirements for an equivalent method determination.
Code of Federal Regulations, 2010 CFR
2010-07-01
... temperature and pressure sensors, outdoor enclosure, electrical power supply, control devices and operator... rate cut-off; operation following power interruptions; effect of variations in power line voltage... other tests, full wind-tunnel tests similar to those described in § 53.62, or to special tests adapted...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ahrens, J.S.
For over fifteen years Sandia National Laboratories has been involved in laboratory testing of biometric identification devices. The key concept of biometric identification devices is the ability for the system to identify some unique aspect of the individual rather than some object a person may be carrying or some password they are required to know. Tests were conducted to verify manufacturer`s performance claims, to determine strengths/weaknesses of devices, and to determine devices that meet the US Department of energy`s needs. However, during recent field installation, significantly different performance was observed than was predicted by laboratory tests. Although most people usingmore » the device believed it operated adequately, the performance observed was over an order of magnitude worse than predicted. The search for reasons behind this gap between the predicted and the actual performance has revealed many possible contributing factors. As engineers, the most valuable lesson to be learned from this experience is the value of scientists and engineers with (1) common sense, (2) knowledge of human behavior, (3) the ability to observe the real world, and (4) the capability to realize the significant differences between controlled experiments and actual installations.« less
Low-profile heliostat design for solar central receiver systems
NASA Technical Reports Server (NTRS)
Fourakis, E.; Severson, A. M.
1977-01-01
Heliostat designs intended to reduce costs and the effect of adverse wind loads on the devices were developed. Included was the low-profile heliostat consisting of a stiff frame with sectional focusing reflectors coupled together to turn as a unit. The entire frame is arranged to turn angularly about a center point. The ability of the heliostat to rotate about both the vertical and horizontal axes permits a central computer control system to continuously aim the sun's reflection onto a selected target. An engineering model of the basic device was built and is being tested. Control and mirror parameters, such as roughness and need for fine aiming, are being studied. The fabrication of these prototypes is in process. The model was also designed to test mirror focusing techniques, heliostat geometry, mechanical functioning, and tracking control. The model can be easily relocated to test mirror imaging on a tower from various directions. In addition to steering and aiming studies, the tests include the effects of temperature changes, wind gusting and weathering. The results of economic studies on this heliostat are also presented.
Gurari, Netta; Baud-Bovy, Gabriel
2014-09-30
The emergence of commercial haptic devices offers new research opportunities to enhance our understanding of the human sensory-motor system. Yet, commercial device capabilities have limitations which need to be addressed. This paper describes the customization of a commercial force feedback device for displaying forces with a precision that exceeds the human force perception threshold. The device was outfitted with a multi-axis force sensor and closed-loop controlled to improve its transparency. Additionally, two force sensing resistors were attached to the device to measure grip force. Force errors were modeled in the frequency- and time-domain to identify contributions from the mass, viscous friction, and Coulomb friction during open- and closed-loop control. The effect of user interaction on system stability was assessed in the context of a user study which aimed to measure force perceptual thresholds. Findings based on 15 participants demonstrate that the system maintains stability when rendering forces ranging from 0-0.20 N, with an average maximum absolute force error of 0.041 ± 0.013 N. Modeling the force errors revealed that Coulomb friction and inertia were the main contributors to force distortions during respectively slow and fast motions. Existing commercial force feedback devices cannot render forces with the required precision for certain testing scenarios. Building on existing robotics work, this paper shows how a device can be customized to make it reliable for studying the perception of weak forces. The customized and closed-loop controlled device is suitable for measuring force perceptual thresholds. Copyright © 2014 Elsevier B.V. All rights reserved.
Monolithically integrated Si gate-controlled light-emitting device: science and properties
NASA Astrophysics Data System (ADS)
Xu, Kaikai
2018-02-01
The motivation of this study is to develop a p-n junction based light emitting device, in which the light emission is conventionally realized using reverse current driving, by voltage driving. By introducing an additional terminal of insulated gate for voltage driving, a novel three-terminal Si light emitting device is described where both the light intensity and spatial light pattern of the device are controlled by the gate voltage. The proposed light emitting device employs injection-enhanced Si in avalanche mode where electric field confinement occurs in the corner of a reverse-biased p+n junction. It is found that, depending on the bias conditions, the light intensity is either a linear or a quadratic function of the applied gate voltage or the reverse-bias. Since the light emission is based on the avalanching mode, the Si light emitting device offers the potential for very large scale integration-compatible light emitters for inter- or intra-chip signal transmission and contactless functional testing of wafers.
Tests of a 1/7-Scale Semispan Model of the XB-35 Airplane in the Langley 19-Foot Pressure Tunnel
NASA Technical Reports Server (NTRS)
Teplitz, Jerome; Kayten, Gerald G.; Cancro, Patrick A.
1946-01-01
A 1/7 scale semispan model of the XB-35 airplane was tested in the Langley 10 foot pressure tunnel, primarily for the purpose of investigating the effectiveness of a leading-edge slot for alleviation of stick-fixed longitudinal instability at high angles of attack caused by early tip stalling and a device for relief of stick-free instability caused by elevon up-floating tendencies at high angles of attack. Results indicated that the slot was not adequate to provide the desired improvement in stick-fixed stability. The tab-flipper device provided improvement in stick-free stability abd two of the linkage combinations tested gave satisfactory variations of control force with airspeed for all conditions except that in which the wing-tip "pitch-control" flap was fully deflected. However, the improvement in control force characteristics was accompanied by a detrimental effect on stick-fixed stability because of the pitching moments produced by the elevon tab deflection.
Qureshi, Muhammad B; Glower, Jacob; Ewert, Daniel L; Koenig, Steven C
2017-06-01
Mechanical circulatory support devices (MCSDs) have gained widespread clinical acceptance as an effective heart failure (HF) therapy. The concept of harnessing the kinetic energy (KE) available in the forward aortic flow (AOF) is proposed as a novel control strategy to further increase the cardiac output (CO) provided by MCSDs. A complete mathematical development of the proposed theory and its application to an example MCSDs (two-segment extra-aortic cuff) are presented. To achieve improved device performance and physiologic benefit, the example MCSD timing is regulated to maximize the forward AOF KE and minimize retrograde flow. The proof-of-concept was tested to provide support with and without KE control in a computational HF model over a wide range of HF test conditions. The simulation predicted increased stroke volume (SV) by 20% (9 mL), CO by 23% (0.50 L/min), left ventricle ejection fraction (LVEF) by 23%, and diastolic coronary artery flow (CAF) by 55% (3 mL) in severe HF at a heart rate (HR) of 60 beats per minute (BPM) during counterpulsation (CP) support with KE control. The proposed KE control concept may improve performance of other MCSDs to further enhance their potential clinical benefits, which warrants further investigation. The next step is to investigate various assist technologies and determine where this concept is best applied. Then bench-test the combination of kinetic energy optimization and its associated technology choice and finally test the combination in animals.
Design and Characterization of an Exoskeleton for Perturbing the Knee During Gait.
Tucker, Michael R; Shirota, Camila; Lambercy, Olivier; Sulzer, James S; Gassert, Roger
2017-10-01
An improved understanding of mechanical impedance modulation in human joints would provide insights about the neuromechanics underlying functional movements. Experimental estimation of impedance requires specialized tools with highly reproducible perturbation dynamics and reliable measurement capabilities. This paper presents the design and mechanical characterization of the ETH Knee Perturbator: an actuated exoskeleton for perturbing the knee during gait. A novel wearable perturbation device was developed based on specific experimental objectives. Bench-top tests validated the device's torque limiting capability and characterized the time delays of the on-board clutch. Further tests demonstrated the device's ability to perform system identification on passive loads with static initial conditions. Finally, the ability of the device to consistently perturb human gait was evaluated through a pilot study on three unimpaired subjects. The ETH Knee Perturbator is capable of identifying mass-spring systems within 15% accuracy, accounting for over 95% of the variance in the observed torque in 10 out of 16 cases. Five-degree extension and flexion perturbations were executed on human subjects with an onset timing precision of 2.52% of swing phase duration and a rise time of 36.5 ms. The ETH Knee Perturbator can deliver safe, precisely timed, and controlled perturbations, which is a prerequisite for the estimation of knee joint impedance during gait. Tools such as this can enhance models of neuromuscular control, which may improve rehabilitative outcomes following impairments affecting gait and advance the design and control of assistive devices.
Code of Federal Regulations, 2010 CFR
2010-10-01
... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.589 Relays. (a) Each relay shall be removed... train stop or train control system, at least once every two years; and (2) All other relays, at least...
Code of Federal Regulations, 2011 CFR
2011-10-01
... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.589 Relays. (a) Each relay shall be removed... train stop or train control system, at least once every two years; and (2) All other relays, at least...
Baghouses are air pollution control devices used to control particulate emissions from stationary sources and are among the technologies evaluated by the APCT Center. Baghouses and their accompanying filter media have long been one of the leading particulate control techniques fo...
Baghouses are air pollution control devices used to control particulate emissions from stationary sources and are among the technologies evaluated by the APCT Center. Baghouses and their accompanying filter media have long been one of the leading particulate control techniques fo...
Baghouses are air pollution control devices used to control particulate emissions from stationary sources and are among the technologies evaluated by the APCT Center. Baghouses and their accompanying filter media have long been one of the leading particulate control techniques fo...
NASA Astrophysics Data System (ADS)
Pathak, Anupam; Brei, Diann; Luntz, Jonathan
2009-03-01
Essential Tremor is a debilitating disorder that in the US alone is estimated to affect up to ten million people. Unfortunately current treatments (i.e. drug therapy and surgical procedures), are limited in effectiveness and often pose a risk of adverse side-effects. In response to this problem, this paper describes an active cancellation device based on a hand-held Shape Memory Alloy (SMA) actuated stabilization platform. The assistive device is designed to hold and stabilize various objects (e.g. eating utensils, tools, pointing implements, etc.) by sensing the user's tremor and moving the object in an opposite direction using SMA actuators configured in biologically inspired antagonistic pairs. To aid in the design, performance prediction and control of the device, a device model is described that accounts for the device kinematics, SMA thermo-mechanics, and the heat transfer resulting from electrical heating and convective cooling. The system of differential equations in this device model coupled with the controller gain can be utilized to design the operation given a frequency range and power requirement. To demonstrate this, a prototype was built and experimentally tested under external disturbances in the range of 1-5 Hz, resulting in amplitude reduction of up to 80%. The extent of cancellation measured for both single-frequencies and actual human tremor disturbances demonstrate the promise of this approach as a broadly used assistive device for the multitudes afflicted by tremor.
Anirudhan, T S; Nair, Syam S; Nair, Anoop S
2016-11-05
A novel efficient transdermal (TD) lidocaine (LD) delivery device based on chitosan (CS) and hyaluronic acid (HA) was successfully developed in the present investigation. CS was grafted with glycidyl methacrylate (GMA) and butyl methacrylate (BMA) to fabricate a versatile material with improved adhesion and mechanical properties. HA was hydrophobically modified by covalently conjugating 3-(dimethylamino)-1-propylamine (DMPA) to encapsulate poorly water soluble LD and was uniformly dispersed in modified CS matrix. The prepared materials were characterized through FTIR, NMR, XRD, SEM, TEM and tensile assay. The dispersion of amine functionalized HA (AHA) on modified CS matrix offered strong matrix - filler interaction, which improved the mechanical properties and drug retention behavior of the device. In vitro skin permeation study of LD was performed with modified Franz diffusion cell using rat skin and exhibited controlled release. The influence of storage time on release profile was investigated and demonstrated that after the initial burst, LD release profile of the device after 30 and 60days storage was identical to that of a device which was not stored. In vivo skin adhesion test and skin irritation assay in human subjects, water vapor permeability and environmental fitness test was performed to judge its application in biomedical field. All results displayed that the fabricated device is a potential candidate for TD LD administration to the systemic circulation. Copyright © 2016 Elsevier Ltd. All rights reserved.
Rossner, Alan; Farant, Jean-Pierre
2004-02-01
Evacuated canisters have been used for many years to collect ambient air samples for gases and vapors. Recently, significant interest has arisen in using evacuated canisters for personal breathing zone sampling as an alternative to sorbent sampling. A novel flow control device was designed and built at McGill University. The flow control device was designed to provide a very low flow rate, <0.5 mL/min, to allow a sample to be collected over an extended period of time. Previous experiments run at McGill have shown agreement between the mathematical and empirical models to predict flow rate. The flow control device combined with an evacuated canister (capillary flow control-canister) was used in a series of experiments to evaluate its performance against charcoal tubes and diffusive badges. Air samples of six volatile organic compounds were simultaneously collected in a chamber using the capillary flow control-canister, charcoal tubes, and diffusive badges. Five different concentrations of the six volatile organic compounds were evaluated. The results from the three sampling devices were compared to each other and to concentration values obtained using an online gas chromatograph (GC). Eighty-four samples of each method were collected for each of the six chemicals. Results indicate that the capillary flow control-canister device compares quite favorably to the online GC and to the charcoal tubes, p > 0.05 for most of the tests. The capillary flow control-canister was found to be more accurate for the compounds evaluated, easier to use, and easier to analyze than charcoal tubes and passive dosimeter badges.