Rokka, A; Mehik, A; Tonttila, P; Vaarala, M
2017-08-15
There are few specific diagnostic markers for chronic prostatitis. Therefore, we used mass spectrometry to evaluate differences in seminal plasma protein expression among patients with prostatitis and young and middle-aged healthy controls. We analysed pooled seminal plasma protein samples from four prostatitis patients (two pools), three young controls (one pool), and three middle-aged controls (one pool). The samples were analysed by liquid chromatography-tandem mass spectrometry. Of the 349 proteins identified, 16 were differentially expressed between the two control pools. Five proteins were up- or down-regulated in both of the prostatitis pools compared to middle-aged controls but not between young and middle-aged pools. Progestagen-associated endometrial protein (PAEP) was over-expressed in prostatitis samples compared to young and middle-aged controls. Our findings and those of previous studies indicate that PAEP is a potential seminal plasma marker for chronic prostatitis. In conclusion, we found age-related changes in seminal plasma protein expression. PAEP expression in seminal plasma should be investigated further to evaluate its potential as a diagnostic marker for chronic prostatitis.
Miller, Ruth R; Uyaguari-Diaz, Miguel; McCabe, Mark N; Montoya, Vincent; Gardy, Jennifer L; Parker, Shoshana; Steiner, Theodore; Hsiao, William; Nesbitt, Matthew J; Tang, Patrick; Patrick, David M
2016-01-01
Myalgic Encephalomyelitis/Chronic Fatigue Syndrome (ME/CFS) is a debilitating disease causing indefinite fatigue. ME/CFS has long been hypothesised to have an infectious cause; however, no specific infectious agent has been identified. We used metagenomics to analyse the RNA from plasma samples from 25 individuals with ME/CFS and compare their microbial content to technical controls as well as three control groups: individuals with alternatively diagnosed chronic Lyme syndrome (N = 13), systemic lupus erythematosus (N = 11), and healthy controls (N = 25). We found that the majority of sequencing reads were removed during host subtraction, thus there was very low microbial RNA content in the plasma. The effects of sample batching and contamination during sample processing proved to outweigh the effects of study group on microbial RNA content, as the few differences in bacterial or viral RNA abundance we did observe between study groups were most likely caused by contamination and batch effects. Our results highlight the importance of including negative controls in all metagenomic analyses, since there was considerable overlap between bacterial content identified in study samples and control samples. For example, Proteobacteria, Firmicutes, Actinobacteria, and Bacteriodes were found in both study samples and plasma-free negative controls. Many of the taxonomic groups we saw in our plasma-free negative control samples have previously been associated with diseases, including ME/CFS, demonstrating how incorrect conclusions may arise if controls are not used and batch effects not accounted for.
The effects of RF plasma ashing on zinc orthotitanate/potassium silicate thermal control coatings
NASA Technical Reports Server (NTRS)
Dever, Joyce A.; Bruckner, Eric J.
1992-01-01
Samples of YB-71, a white thermal control coating composed of zinc orthotitanate pigment in a potassium silicate binder, were exposed in air plasma and in oxygen plasma to determine optical property and surface chemistry changes. Results show that YB-71 undergoes a significant reflectance decrease upon exposure to the simulated LEO atomic oxygen environment provided by an air plasma asher. YB-71 samples exposed to the same effective fluence in oxygen plasma, or in a UV screening Faraday cage in air or oxygen, do not undergo as severe reflectance decreases as the samples exposed in the air plasma asher environment. The UV and VUV radiation present in the plasma ashers affects the YB-71 degradation. It is noted that, when using plasma ashers to determine LEO degradation, it is necessary to take into account the sensitivity of the material to the synergistic effects of atomic oxygen and accelerated UV radiation.
Kay, Richard G; Challis, Benjamin G; Casey, Ruth T; Roberts, Geoffrey P; Meek, Claire L; Reimann, Frank; Gribble, Fiona M
2018-06-01
Diagnosis of pancreatic neuroendocrine tumours requires the study of patient plasma with multiple immunoassays, using multiple aliquots of plasma. The application of mass spectrometry based techniques could reduce the cost and amount of plasma required for diagnosis. Plasma samples from two patients with pancreatic neuroendocrine tumours were extracted using an established acetonitrile based plasma peptide enrichment strategy. The circulating peptidome was characterised using nano and high flow rate LC/MS analyses. To assess the diagnostic potential of the analytical approach, a large sample batch (68 plasmas) from control subjects, and aliquots from subjects harbouring two different types of pancreatic neuroendocrine tumour (insulinoma and glucagonoma) were analysed using a 10-minute LC/MS peptide screen. The untargeted plasma peptidomics approach identified peptides derived from the glucagon prohormone, chromogranin A, chromogranin B and other peptide hormones and proteins related to control of peptide secretion. The glucagon prohormone derived peptides that were detected were compared against putative peptides that were identified using multiple antibody pairs against glucagon peptides. Comparison of the plasma samples for relative levels of selected peptides showed clear separation between the glucagonoma and the insulinoma and control samples. The combination of the organic solvent extraction methodology with high flow rate analysis could potentially be used to aid diagnosis and monitor treatment of patients with functioning pancreatic neuroendocrine tumours. However, significant validation will be required before this approach can be clinically applied. This article is protected by copyright. All rights reserved.
Controlling protein adsorption on graphene for cryo-EM using low-energy hydrogen plasmas
Russo, Christopher J.; Passmore, Lori A.
2014-01-01
Despite its many favorable properties as a sample support for biological electron microscopy, graphene is not widely used because its hydrophobicity precludes reliable protein deposition. We describe a method to modify graphene using a low-energy hydrogen plasma, which reduces hydrophobicity without degrading the graphene lattice. We show that the use of plasma-treated graphene enables better control of protein distribution in ice for electron cryo-microscopy and improved image quality by reducing radiation-induced sample motion. PMID:24747813
Doping control study of AICAR in post-race urine and plasma samples from horses.
Wong, Jenny K Y; Kwok, Wai Him; Chan, George H M; Choi, Timmy L S; Ho, Emmie N M; Jaubert, Murielle; Bailly-Chouriberry, Ludovic; Bonnaire, Yves; Cawley, Adam; Ming Williams, H; Keledjian, John; Brooks, Lydia; Chambers, Adam; Lin, Yuanyuan; Wan, Terence S M
2017-09-01
Acadesine, 5-aminoimidazole-4-carboxamide-1-β-D-ribofuranoside, commonly known as AICAR, is a naturally occurring adenosine monophosphate-activated protein kinase (AMPK) activator in many mammals, including humans and horses. AICAR has attracted considerable attention recently in the field of doping control because of a study showing the enhancement of endurance performance in unexercised or untrained mice, resulting in the term 'exercise pill'. Its use has been classified as gene doping by the World Anti-Doping Agency (WADA), and since it is endogenous, it may only be possible to control deliberate administration of AICAR to racehorses after establishment of an appropriate threshold. Herein we report our studies of AICAR in post-race equine urine and plasma samples including statistical studies of AICAR concentrations determined from 1,470 urine samples collected from thoroughbreds and standardbreds and analyzed in Australia, France, and Hong Kong. Quantification methods in equine urine and plasma using liquid chromatography-mass spectrometry were developed by the laboratories in each country. An exchange of spiked urine and plasma samples between the three countries was conducted, confirming no significant differences in the methods. However, the concentration of AICAR in plasma was found to increase upon haemolysis of whole blood samples, impeding the establishment of a suitable threshold in equine plasma. A possible urine screening cut-off at 600 ng/mL for the control of AICAR in racehorses could be considered for adoption. Application of the proposed screening cut-off to urine samples collected after intravenous administration of a small dose (2 g) of AICAR to a mare yielded a short detection time of approximately 4.5 h. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Plasma antibodies to Abeta40 and Abeta42 in patients with Alzheimer's disease and normal controls.
Xu, Wuhua; Kawarabayashi, Takeshi; Matsubara, Etsuro; Deguchi, Kentaro; Murakami, Tetsuro; Harigaya, Yasuo; Ikeda, Masaki; Amari, Masakuni; Kuwano, Ryozo; Abe, Koji; Shoji, Mikio
2008-07-11
Antibodies to amyloid beta protein (Abeta) are present naturally or after Abeta vaccine therapy in human plasma. To clarify their clinical role, we examined plasma samples from 113 patients with Alzheimer's disease (AD) and 205 normal controls using the tissue amyloid plaque immunoreactivity (TAPIR) assay. A high positive rate of TAPIR was revealed in AD (45.1%) and age-matched controls (41.2%), however, no significance was observed. No significant difference was observed in the MMS score or disease duration between TAPIR-positive and negative samples. TAPIR-positive plasma reacted with the Abeta40 monomer and dimer, and the Abeta42 monomer weakly, but not with the Abeta42 dimer. TAPIR was even detected in samples from young normal subjects and young Tg2576 transgenic mice. Although the Abeta40 level and Abeta40/42 ratio increased, and Abeta42 was significantly decreased in plasma from AD groups when compared to controls, no significant correlations were revealed between plasma Abeta levels and TAPIR grading. Thus an immune response to Abeta40 and immune tolerance to Abeta42 occurred naturally in humans without a close relationship to the Abeta burden in the brain. Clarification of the mechanism of the immune response to Abeta42 is necessary for realization of an immunotherapy for AD.
NASA Astrophysics Data System (ADS)
Matsui, Kei; Ikenaga, Noriaki; Sakudo, Noriyuki
2015-06-01
We investigate the effects of relative humidity on the sterilization process using a plasma-excited neutral gas that uniformly sterilizes both the space and inner wall of the reactor chamber at atmospheric pressure. Only reactive neutral species such as plasma-excited gas molecules and radicals were separated from the plasma and sent to the reactor chamber for chemical sterilization. The plasma source gas is nitrogen mixed with 0.1% oxygen, and the relative humidity in the source gas is controlled by changing the mixing ratio of water vapor. The relative humidity near the sample in the reactor chamber is controlled by changing the sample temperature. As a result, the relative humidity near the sample should be kept in the range from 60 to 90% for the sterilization of Geobacillus stearothermophilus spores. When the relative humidity in the source gas increases from 30 to 90%, the sterilization effect is enhanced by the same degree.
Pashmakova, Medora B; Barr, James W; Bishop, Micah A
2015-05-01
To compare stability of hemostatic proteins in canine fresh-frozen plasma (FFP) thawed with a modified commercial microwave warmer (MCM) or warm water bath (37°C; WWB) or at room temperature (22°C). Fresh-frozen plasma obtained from 8 canine donors of a commercial blood bank. A commercial microwave warmer was modified with a thermocouple to measure surface temperature of bags containing plasma. The MCM and a WWB were each used to concurrently thaw a 60-mL bag of plasma obtained from the same donor. Two 3-mL control aliquots of FFP from each donor were thawed to room temperature without use of a heating device. Concentrations of hemostatic proteins, albumin, and D-dimers; prothrombin time (PT); and activated partial thromboplastin time (aPTT) were determined for all samples. Significant decreases in concentrations of factors II, IX, X, XI, fibrinogen, von Willebrand factor, antithrombin, protein C, and albumin and significant increases in PT and aPTT were detected for plasma thawed with the MCM, compared with results for samples thawed with the WWB. Concentrations of factors VII, VIII, and XII were not significantly different between plasma thawed with the MCM and WWB. Concentrations of D-dimers were above the reference range for all thawed samples regardless of thawing method. No significant differences in factor concentrations were detected between control and WWB-thawed samples. Significant differences in hemostatic protein concentrations and coagulation times were detected for plasma thawed with an MCM but not between control and WWB-thawed samples. Clinical importance of these changes should be investigated.
Springer, Jan; White, P Lewis; Hamilton, Shanna; Michel, Denise; Barnes, Rosemary A; Einsele, Hermann; Löffler, Juergen
2016-03-01
Standardized methodologies for the molecular detection of invasive aspergillosis (IA) have been established by the European Aspergillus PCR Initiative for the testing of whole blood, serum, and plasma. While some comparison of the performance of Aspergillus PCR when testing these different sample types has been performed, no single study has evaluated all three using the recommended protocols. Standardized Aspergillus PCR was performed on 423 whole-blood pellets (WBP), 583 plasma samples, and 419 serum samples obtained from hematology patients according to the recommendations. This analysis formed a bicenter retrospective anonymous case-control study, with diagnosis according to the revised European Organization for Research and Treatment of Cancer/Invasive Fungal Infections Cooperative Group and National Institute of Allergy and Infectious Diseases Mycoses Study Group (EORTC/MSG) consensus definitions (11 probable cases and 36 controls). Values for clinical performance using individual and combined samples were calculated. For all samples, PCR positivity was significantly associated with cases of IA (for plasma, P = 0.0019; for serum, P = 0.0049; and for WBP, P = 0.0089). Plasma PCR generated the highest sensitivity (91%); the sensitivities for serum and WBP PCR were 80% and 55%, respectively. The highest specificity was achieved when testing WBP (96%), which was significantly superior to the specificities achieved when testing serum (69%, P = 0.0238) and plasma (53%, P = 0.0002). No cases were PCR negative in all specimen types, and no controls were PCR positive in all specimens. This study confirms that Aspergillus PCR testing of plasma provides robust performance while utilizing commercial automated DNA extraction processes. Combining PCR testing of different blood fractions allows IA to be both confidently diagnosed and excluded. A requirement for multiple PCR-positive plasma samples provides similar diagnostic utility and is technically less demanding. Time to diagnosis may be enhanced by testing multiple contemporaneously obtained sample types. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
NASA Technical Reports Server (NTRS)
Hillard, G. Barry
1993-01-01
A sample of Z-93 thermal control paint was exposed to a simulated space environment in a plasma chamber. The sample was biased through a series of voltages ranging from -100 volts to +300 volts and electron and ion currents were measured. Currents were found to be in the micro-ampere range indicating that the material remains a reasonably good insulator under plasma conditions. As a second step, the sample was left in the chamber for six days and retested. Collected currents were reduced by from two to five times from the previous values indicating a substantial loss of conductivity. As a final test, the sample was removed, exposed to room conditions for two days, and returned to the chamber. Current measurements showed that the sample had partially recovered the lost conductivity. In addition to presenting these results, this report documents all of the experimental data as well as the statistical analyses performed.
Shevchenko, Valeriy E; Arnotskaya, Natalia E; Zaridze, David G
2010-01-01
There are no satisfactory plasma biomarkers which are available for the early detection and monitoring of lung cancer, one of the most frequent cancers worldwide. The aim of this study is to explore the application of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-ToF MS) to plasma proteomic patterns to distinguish lung cancer patients from healthy individuals. The EDTA plasma samples have been pre-fractionated using magnetic bead kits functionalized with weak cation exchange coatings. We compiled MS protein profiles for 90 patients with squamous cell carcinomas (SCC) and compared them with profiles from 187 healthy controls. The MALDI-ToF spectra were analyzed statistically using ClinProTools bioinformatics software. Depending on the sample used, up to 441 peaks/spectrum could be detected in a mass range of 1000-20,000 Da; 33 of these proteins had statistically differential expression levels between SCC and control plasma (P < 0.001). The series of the peaks were automatically chosen as potential biomarker patterns in the training set. They allowed the discrimination of plasma samples from healthy control and samples from SCC patients (sensitivity and specificity >90%) in external validation test. These results suggest that plasma MALDI-ToF MS protein profiling can distinguish patients with SCC and also from healthy individuals with relatively high sensitivity and specificity and that MALDI- ToF MS is a potential tool for the screening of lung cancer.
Plasma galanin is a biomarker for severity of major depressive disorder.
Wang, Yong-Jun; Yang, Yu-Tao; Li, Hui; Liu, Po-Zi; Wang, Chuan-Yue; Xu, Zhi-Qing David
2014-01-01
This study investigated the association between plasma galanin level and depression severity. The severity of depression symptoms of 79 patients with major depressive disorder (MDD; 52 women and 27 men, 71 patients in onset, 8 in remission) was assessed using the 17-item Hamilton Depression Rating Scale. Venous fasting blood samples (5 mL) were taken from the 79 MDD patients, 35 healthy siblings, and 19 healthy controls, and plasma samples were prepared. Galanin levels in the plasma were measured by radioimmunoassay. Plasma galanin in MDD patients was significantly higher than that of remission patients, healthy siblings, or healthy controls (P < 0.05) There was no significant difference between the healthy sibling and healthy control groups (P = 0.924). Plasma galanin of remission patients was also significantly higher than that of healthy controls (P < 0.05). There was no significant correlation between age and galanin levels in the 79 patients (r = 0.053, P = 0.646), nor was there a correlation between age and galanin levels when patients were stratified by gender (P > 0.05). There was a significant positive correlation between plasma galanin levels and depression severity in women MDD patients (r = 0.329, df = 42, P = 0.020), but not in men patients. Plasma galanin levels may be an important biomarker for depression severity, especially in female patients.
An integrated bioanalytical method development and validation approach: case studies.
Xue, Y-J; Melo, Brian; Vallejo, Martha; Zhao, Yuwen; Tang, Lina; Chen, Yuan-Shek; Keller, Karin M
2012-10-01
We proposed an integrated bioanalytical method development and validation approach: (1) method screening based on analyte's physicochemical properties and metabolism information to determine the most appropriate extraction/analysis conditions; (2) preliminary stability evaluation using both quality control and incurred samples to establish sample collection, storage and processing conditions; (3) mock validation to examine method accuracy and precision and incurred sample reproducibility; and (4) method validation to confirm the results obtained during method development. This integrated approach was applied to the determination of compound I in rat plasma and compound II in rat and dog plasma. The effectiveness of the approach was demonstrated by the superior quality of three method validations: (1) a zero run failure rate; (2) >93% of quality control results within 10% of nominal values; and (3) 99% incurred sample within 9.2% of the original values. In addition, rat and dog plasma methods for compound II were successfully applied to analyze more than 900 plasma samples obtained from Investigational New Drug (IND) toxicology studies in rats and dogs with near perfect results: (1) a zero run failure rate; (2) excellent accuracy and precision for standards and quality controls; and (3) 98% incurred samples within 15% of the original values. Copyright © 2011 John Wiley & Sons, Ltd.
Stress assessment using hair cortisol of kangaroos affected by the lumpy jaw disease.
Sotohira, Yukari; Suzuki, Kazuyuki; Sano, Tadashi; Arai, Chigusa; Asakawa, Mitsuhiko; Hayashi, Hideaki
2017-05-03
The aim of this study was to objectively assess stress of kangaroos affected by lumpy jaw disease (LJD) using plasma and hair cortisol concentrations. The plasma and hair samples were collected from kangaroos with LJD and healthy controls. Collected hair samples were extracted with methanol after washing with isopropanol, following which they were processed with the cortisol enzyme immunoassay kit. The plasma cortisol concentration of LJD animals tended to be higher than that of the control. Ventral hair cortisol, but not dorsal hair, of LJD animals was significantly higher than that of the control. In conclusion, stress in kangaroos infected with LJD could be assessed by measuring ventral hair cortisol.
2017-09-01
performed on pre -collected plasma samples from a study that had a two- group cross-sectional design in which main comparisons were with medically...controls. Approach Metabolomic analysis will be performed on pre -collected plasma samples from a study that had a two- group cross-sectional design in...disturbances, and health. Metabolomic analysis will be performed on pre -collected plasma samples from a study that had a two- group cross-sectional
Baser, Ulku; Gamsiz-Isik, Hikmet; Cifcibasi, Emine; Ademoglu, Evin; Yalcin, Funda
2015-07-01
To evaluate the plasma and salivary total antioxidant capacity (TAOC) in patients with generalized chronic periodontitis (CP), generalized aggressive periodontitis (AgP), and periodontally healthy controls. This cross-sectional study includes of 88 individuals seeking dental treatment at the Faculty of Dentistry, Istanbul University, Istanbul, Turkey between January 2011 and March 2012. Fifteen AgP patients were compared with 21 healthy controls (C1), while 36 CP patients were compared with 16 healthy controls (C2). Clinical periodontal measurements were recorded, and plasma and saliva samples were collected. The TAOC of the plasma and saliva samples were determined using a commercially available colorimetric kit. The plasma TAOC of both AgP and CP patients was significantly lower for C1 and C2. The salivary TAOC of CP patients was significantly lower for C2, but there was no significant difference between AgP patients and C1. Our results demonstrate that severe periodontitis may be associated with a lower plasma antioxidant capacity. The reduced antioxidant capacity in patients with severe periodontitis, especially with aggressive forms may be an important contributing factor to severe tissue destruction.
Method and apparatus for chemical and topographical microanalysis
NASA Technical Reports Server (NTRS)
Kossakovski, Dmitri A. (Inventor); Baldeschwieler, John D. (Inventor); Beauchamp, Jesse L. (Inventor)
2002-01-01
A scanning probe microscope is combined with a laser induced breakdown spectrometer to provide spatially resolved chemical analysis of the surface correlated with the surface topography. Topographical analysis is achieved by scanning a sharp probe across the sample at constant distance from the surface. Chemical analysis is achieved by the means of laser induced breakdown spectroscopy by delivering pulsed laser radiation to the sample surface through the same sharp probe, and consequent collection and analysis of emission spectra from plasma generated on the sample by the laser radiation. The method comprises performing microtopographical analysis of the sample with a scanning probe, selecting a scanned topological site on the sample, generating a plasma plume at the selected scanned topological site, and measuring a spectrum of optical emission from the plasma at the selected scanned topological site. The apparatus comprises a scanning probe, a pulsed laser optically coupled to the probe, an optical spectrometer, and a controller coupled to the scanner, laser and spectrometer for controlling the operation of the scanner, laser and spectrometer. The probe and scanner are used for topographical profiling the sample. The probe is also used for laser radiation delivery to the sample for generating a plasma plume from the sample. Optical emission from the plasma plume is collected and delivered to the optical spectrometer so that analysis of emission spectrum by the optical spectrometer allows for identification of chemical composition of the sample at user selected sites.
Beijerink, Niek J; Lee, Wei M; Stokhof, Arnold A; Voorhout, George; Mol, Jan A; Kooistra, Hans S
2011-01-01
To evaluate plasma concentrations of growth hormone (GH) and insulin-like growth factor I (IGF-I) in healthy dogs and large-breed dogs with dilated cardiomyopathy (DCM). 8 dogs with DCM and 8 healthy control dogs of comparable age and body weight. Blood samples for determination of the pulsatile plasma GH profile were collected from all dogs at 10-minute intervals between 8:00 am and 8:00 pm. Plasma IGF-I concentration was determined in the blood sample collected at 8:00 am. No significant differences in plasma IGF-I concentrations, basal plasma GH concentration, GH pulse frequency, area under the curve above the zero line and above the baseline for GH, and GH pulse amplitude were found between dogs with DCM and control dogs. Results did not provide evidence for an association between DCM in dogs and a reduction in plasma concentrations of GH or IGF-I. Therefore, reported positive effects of GH administration are most likely attributable to local effects in the heart.
Effect of parvoviral enteritis on plasma citrulline concentration in dogs.
Dossin, O; Rupassara, S I; Weng, H-Y; Williams, D A; Garlick, P J; Schoeman, J P
2011-01-01
Plasma citrulline concentration is a reliable marker of global enterocyte mass in humans and is markedly decreased in diffuse small intestinal diseases. However, the relationship between acute intestinal damage and plasma citrulline concentration in dogs has never been documented. That dogs with parvoviral enteritis have a lower plasma citrulline concentration than healthy dogs and that plasma citrulline concentration is a predictor of death in puppies with parvoviral enteritis. Sixty-one dogs with spontaneous parvoviral enteritis and 14 healthy age-matched control dogs. Observational cohort study. Plasma citrulline concentration was measured by liquid chromatography and tandem mass spectrometry in blood samples collected at admission and each day until death or discharge from the hospital. Parvovirus enteritis was confirmed by electron microscopy on a fecal sample. Median (interquartile range) plasma citrulline concentrations at admission were 2.8 μmol/L (range: 0.3, 49.0; P < .001 versus controls) in survivors (n = 49), 2.1 μmol/L (range: 0.5, 6.4, P < .001 versus controls) in nonsurvivors (n = 12) and 38.6 μmol/L (range: 11.4, 96.1) in controls (n = 14), respectively. There was no significant difference in plasma citrulline concentration between survivors and nonsurvivors within the parvovirus-infected puppies, and plasma citrulline concentration was not significantly associated with outcome in parvoviral enteritis. There were no significant changes in plasma citrulline concentration over the 8-day follow-up period. Parvovirus enteritis is associated with a severe decrease in plasma citrulline concentration that does not appear to have any significant prognostic value. Copyright © 2011 by the American College of Veterinary Internal Medicine.
NASA Astrophysics Data System (ADS)
Dementeva, N.; Ivanova, K.; Kokova, D.; Kurzina, I.; Ponomaryova, A.; Kzhyshkowska, J.
2017-09-01
Lung cancer is one of the most common types of cancer leading to death. Consequently, the search and the identification of the metabolites associated with the risk of developing cancer are very valuable. For the purpose, untargeted metabolic profiling of the plasma samples collected from the patients with lung cancer (n = 100) and the control group (n = 100) was conducted. After sample preparation, the plasma samples were analyzed using LC-MS method. Biostatistics methods were applied to pre-process the data for elicitation of dominating metabolites which responded to the difference between the case and the control groups. At least seven significant metabolites were evaluated and annotated. The most part of identified metabolites are connected with lipid metabolism and their combination could be useful for follow-up studies of lung cancer pathogenesis.
Controlling the misuse of cobalt in horses.
Ho, Emmie N M; Chan, George H M; Wan, Terence S M; Curl, Peter; Riggs, Christopher M; Hurley, Michael J; Sykes, David
2015-01-01
Cobalt is a well-established inducer of hypoxia-like responses, which can cause gene modulation at the hypoxia inducible factor pathway to induce erythropoietin transcription. Cobalt salts are orally active, inexpensive, and easily accessible. It is an attractive blood doping agent for enhancing aerobic performance. Indeed, recent intelligence and investigations have confirmed cobalt was being abused in equine sports. In this paper, population surveys of total cobalt in raceday samples were conducted using inductively coupled plasma mass spectrometry (ICP-MS). Urinary threshold of 75 ng/mL and plasma threshold of 2 ng/mL could be proposed for the control of cobalt misuse in raceday or in-competition samples. Results from administration trials with cobalt-containing supplements showed that common supplements could elevate urinary and plasma cobalt levels above the proposed thresholds within 24 h of administration. It would therefore be necessary to ban the use of cobalt-containing supplements on raceday as well as on the day before racing in order to implement and enforce the proposed thresholds. Since the abuse with huge quantities of cobalt salts can be done during training while the use of legitimate cobalt-containing supplements are also allowed, different urinary and plasma cobalt thresholds would be required to control cobalt abuse in non-raceday or out-of-competition samples. This could be achieved by setting the thresholds above the maximum urinary and plasma cobalt concentrations observed or anticipated from the normal use of legitimate cobalt-containing supplements. Urinary threshold of 2000 ng/mL and plasma threshold of 10 ng/mL were thus proposed for the control of cobalt abuse in non-raceday or out-of-competition samples. Copyright © 2014 John Wiley & Sons, Ltd.
Herrera, Marcelino; Aragão, Cláudia; Hachero, Ismael; Ruiz-Jarabo, Ignacio; Vargas-Chacoff, Luis; Mancera, Juan Miguel; Conceição, Luis E C
2012-12-01
The physiological responses of Senegalese sole to a sudden salinity change were investigated. The fish were first acclimated to an initial salinity of 37.5 ppt for 4 h. Then, one group was subjected to increased salinity (55 ppt) while another group was subjected to decreased salinity (5 ppt). The third group (control group) remained at 37.5 ppt. We measured the oxygen consumption rate, osmoregulatory (plasma osmolality, gill and kidney Na(+),K(+)-ATPase activities) and stress (plasma cortisol and metabolites) parameters 0.5 and 3 h after transfer. Oxygen consumption at both salinities was higher than for the control at both sampling times. Gill Na(+),K(+)-ATPase activity was significantly higher for the 55 ppt salinity at 0.5 h. Plasma osmolality decreased in the fish exposed to 5 ppt at the two sampling times but no changes were detected for high salinities. Plasma cortisol levels significantly increased at both salinities, although these values declined in the low-salinity group 3 h after transfer. Plasma glucose at 5 ppt salinity did not vary significantly at 0.5 h but decreased at 3 h, while lactate increased for both treatments at the first sampling time and returned to the control levels at 3 h. Overall, the physiological response of S. senegalensis was immediate and involved a rise in oxygen consumption and plasma cortisol values as well as greater metabolite mobilization at both salinities.
NASA Astrophysics Data System (ADS)
Engel, Thierry; Kane, M.; Fontaine, Joel
1997-08-01
During high-power laser welding, gas ionization occurs above the sample. The resulting plasma ignition threshold is related to ionization potential of metallic vapors from the sample, and shielding gases used in the process. In this work, we have characterized the temporal behavior of the radiation emitted by the plasma during laser welding in order to relate the observed signals to the process parameters.
Arjunan, Krishna Priya; Friedman, Gary; Fridman, Alexander; Clyne, Alisa Morss
2012-01-07
Vascularization plays a key role in processes such as wound healing and tissue engineering. Non-thermal plasma, which primarily produces reactive oxygen species (ROS), has recently emerged as an efficient tool in medical applications including blood coagulation, sterilization and malignant cell apoptosis. Liquids and porcine aortic endothelial cells were treated with a non-thermal dielectric barrier discharge plasma in vitro. Plasma treatment of phosphate-buffered saline (PBS) and serum-free medium increased ROS concentration in a dose-dependent manner, with a higher concentration observed in serum-free medium compared with PBS. Species concentration inside cells peaked 1 h after treatment, followed by a decrease 3 h post treatment. Endothelial cells treated with a plasma dose of 4.2 J cm(-2) had 1.7 times more cells than untreated samples 5 days after plasma treatment. The 4.2 J cm(-2) plasma dose increased two-dimensional migration distance by 40 per cent compared with untreated control, while the number of cells that migrated through a three-dimensional collagen gel increased by 15 per cent. Tube formation was also enhanced by plasma treatment, with tube lengths in plasma-treated samples measuring 2.6 times longer than control samples. A fibroblast growth factor-2 (FGF-2) neutralizing antibody and ROS scavengers abrogated these angiogenic effects. These data indicate that plasma enhanced proliferation, migration and tube formation is due to FGF-2 release induced by plasma-produced ROS. Non-thermal plasma may be used as a potential tool for applying ROS in precise doses to enhance vascularization.
Non-thermal dielectric barrier discharge plasma induces angiogenesis through reactive oxygen species
Arjunan, Krishna Priya; Friedman, Gary; Fridman, Alexander; Clyne, Alisa Morss
2012-01-01
Vascularization plays a key role in processes such as wound healing and tissue engineering. Non-thermal plasma, which primarily produces reactive oxygen species (ROS), has recently emerged as an efficient tool in medical applications including blood coagulation, sterilization and malignant cell apoptosis. Liquids and porcine aortic endothelial cells were treated with a non-thermal dielectric barrier discharge plasma in vitro. Plasma treatment of phosphate-buffered saline (PBS) and serum-free medium increased ROS concentration in a dose-dependent manner, with a higher concentration observed in serum-free medium compared with PBS. Species concentration inside cells peaked 1 h after treatment, followed by a decrease 3 h post treatment. Endothelial cells treated with a plasma dose of 4.2 J cm–2 had 1.7 times more cells than untreated samples 5 days after plasma treatment. The 4.2 J cm–2 plasma dose increased two-dimensional migration distance by 40 per cent compared with untreated control, while the number of cells that migrated through a three-dimensional collagen gel increased by 15 per cent. Tube formation was also enhanced by plasma treatment, with tube lengths in plasma-treated samples measuring 2.6 times longer than control samples. A fibroblast growth factor-2 (FGF-2) neutralizing antibody and ROS scavengers abrogated these angiogenic effects. These data indicate that plasma enhanced proliferation, migration and tube formation is due to FGF-2 release induced by plasma-produced ROS. Non-thermal plasma may be used as a potential tool for applying ROS in precise doses to enhance vascularization. PMID:21653568
Parker, Suzanne L; Lipman, Jeffrey; Dimopoulos, George; Roberts, Jason A; Wallis, Steven C
2015-11-10
Quantification of fosfomycin in the plasma samples of patients is the basis of clinical pharmacokinetic studies from which evidence based dosing regimens can be devised to maximise antibiotic effectiveness against a pathogen. We have developed and validated a LC-MS/MS method to quantify fosfomycin using dried plasma spot sampling. Following HILIC chromatography, fosfomycin and ethylphosphonic acid, used as internal standard, were measured using negative-ion multiple reaction monitoring. The method was linear over the calibration range of 5-2000mg/L of fosfomycin. Intra-day assay results for dried plasma spot quality control samples at 15.6, 79.9 and 1581mg/L of fosfomycin had precision of ±4.2, 8.2, and 2.0%, respectively, and accuracy of +3.9, -0.1, and -1.2%, respectively. Recovery of fosfomycin from dried plasma spots was calculated as 83.6% and the dried plasma spot samples were found to be stable stored at room temperature for three months and when stored for four hours at 50°C. A Bland-Altman plot comparing DPS to plasma sampling found a negative bias of 16.6%, with all but one sample within the mean limits of agreement (-2.6 to 30.6%). Dried plasma spot sampling provides a useful tool for pharmacokinetic research of fosfomycin. Copyright © 2015 Elsevier B.V. All rights reserved.
Appel, David I.; Brinda, Bryan; Markowitz, John S.; Newcorn, Jeffrey H.; Zhu, Hao-Jie
2012-01-01
A simple, rapid and sensitive method for quantification of atomoxetine by liquid chromatography- tandem mass spectrometry (LC-MS/MS) was developed. This assay represents the first LC-MS/MS quantification method for atomoxetine utilizing electrospray ionization. Deuterated atomoxetine (d3-atomoxetine) was adopted as the internal standard. Direct protein precipitation was utilized for sample preparation. This method was validated for both human plasma and in vitro cellular samples. The lower limit of quantification was 3 ng/ml and 10 nM for human plasma and cellular samples, respectively. The calibration curves were linear within the ranges of 3 ng/ml to 900 ng/ml and 10 nM to 10 μM for human plasma and cellular samples, respectively (r2 > 0.999). The intra- and inter-day assay accuracy and precision were evaluated using quality control samples at 3 different concentrations in both human plasma and cellular lysate. Sample run stability, assay selectivity, matrix effect, and recovery were also successfully demonstrated. The present assay is superior to previously published LC-MS and LC-MS/MS methods in terms of sensitivity or the simplicity of sample preparation. This assay is applicable to the analysis of atomoxetine in both human plasma and in vitro cellular samples. PMID:22275222
Single clay sheets inside electrospun polymer nanofibers
NASA Astrophysics Data System (ADS)
Sun, Zhaohui
2005-03-01
Nanofibers were prepared from polymer solution with clay sheets by electrospinning. Plasma etching, as a well controlled process, was used to supply electrically excited gas molecules from a glow discharge. To reveal the structure and arrangement of clay layers in the polymer matrix, plasma etching was used to remove the polymer by controlled gasification to expose the clay sheets due to the difference in reactivity. The shape, flexibility, and orientation of clay sheets were studied by transmission and scanning electron microscopy. Additional quantitative information on size distribution and degree of exfoliation of clay sheets were obtained by analyzing electron micrograph of sample after plasma etching. Samples in various forms including fiber, film and bulk, were thinned by plasma etching. Morphology and dispersion of inorganic fillers were studied by electron microscopy.
Bioassay of procoagulant albumin in human plasma.
Grosset, A; Liu, L; Parker, C J; Rodgers, G M
1994-09-01
Procoagulant albumin (P-Al) is present in normal human plasma and increases monocyte and endothelial cell expression of tissue factor activity. To develop a bioassay for P-Al, we partially purified plasma from healthy volunteers and several patient groups using BaCl2 and (NH4)2SO4 precipitation. The samples were assayed for tissue factor (TF) inducing activity, expressed as a percentage increase compared to a serum-free media control. Over six months, the assay was reproducible in stored samples and in serial samples from normal volunteers. The plasma P-Al activities of 35 volunteers averaged 141 +/- 8.2% (SEM). There was no diurnal variation. There was no difference in the P-Al activity after a 12 hour fast and 2 hours after a large meal in 4 healthy volunteers. There was no increase in activity (r = 0.16) with the subject's age. The average activity from 16 poorly-controlled diabetics was 131 +/- 11% (SEM). No alteration in activity was seen with samples from patients with uremia, liver dysfunction, hemophilia, thrombotic events, or adenocarcinoma. These results indicate that P-Al activity can be bioassayed in individual patient samples; however, pathologic states associated with abnormal P-Al-induced tissue factor activity presently remain unidentified.
Gantner, Pierre; Assoumou, Lambert; Leruez-Ville, Marianne; David, Ludivine; Suzan-Monti, Marie; Costagliola, Dominique; Rouzioux, Christine; Ghosn, Jade
2016-11-01
Intermittent seminal HIV-RNA detection can occur in MSM despite concomitant plasma virological control on combined ART (cART). We undertook the present study to determine if seminal HIV detection was associated with seminal cytomegalovirus (CMV) detection or detection of HIV-infected cells in semen. Longitudinal semen samples from HIV-1-infected MSM on successful cART enrolled in the EVARIST ANRS EP 49 study were analysed. We first conducted a case-control analysis (ratio 1 : 3) to assess HIV-DNA detection in semen cells in the 20 patients with detectable HIV-RNA in seminal plasma (cases) matched with 60 participants with undetectable HIV-RNA (controls) based on total HIV-DNA load in blood cells. Second, we measured CMV-DNA in all seminal plasma samples. HIV-1-DNA in semen cells was detected on at least one sample visit in 12/20 cases and 11/60 controls. Detection of HIV-RNA in seminal plasma was associated significantly with the detection of HIV-DNA in semen cells [OR, 7.6 (95% CI, 2.1-28.4); P = 0.002] when adjusted on total HIV-DNA in blood cells. CMV-DNA was detected in 107/273 seminal plasma samples with a median value of 3.62 log 10 copies/mL (IQR, 2.83-4.38), yielding a prevalence of 39.2%. Seminal CMV-DNA shedding [OR, 1.5 (95% CI, 0.6-3.6); P = 0.343] was not associated with the risk of detection of HIV-RNA in seminal plasma. The presence of HIV-DNA in semen cells was predictive of HIV-RNA detection, suggesting that viral particles arise through local HIV replication by infected semen cells. Despite virological control, compartmentalization of HIV in the genital tract might act in residual replication and transmission. © The Author 2016. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Arnold, Myrtha; Langhans, Wolfgang
2010-04-19
Blood is routinely sampled from laboratory animals in biomedical research, and many of the commonly applied sampling techniques require anesthesia. Acute effects of many sampling and anesthesia procedures may confound the results, but those effects are incompletely characterized. We here compare the effects of four common anesthesia procedures (inhalation anesthesia with ether (EA) or isoflurane (IA) and intraperitoneal injection anesthesia with xylazin/ketamine (XKA) or medetomidine/midazolam/fentanyl (MMFA)) on plasma concentrations of glucose, lactate, non-esterified fatty acids (NEFAs), and corticosterone in blood obtained from a previously implanted jugular vein (JV) catheter with the effect of JV blood sampling from non-anesthetized, freely-moving rats (JV-NA). Also, we included in the comparison two other blood sampling procedures usually performed without anesthesia (NA), i.e., puncture of the saphenic vein (SV) and tail incision (TI). Whereas the control procedure (JV-NA) did not significantly affect any of the target parameters, plasma glucose increased from 14 (JV-IA) to 44 (JV-MMFA) % (all Ps=0.05 when compared with the control procedure) in all blood samples collected in anesthesia and was 12 and 14% lower (both Ps<0.05) in SV-NA and TI-NA samples, respectively. Plasma lactate increased from 74 (JV-IA) to 226% (SV-NA) (all Ps<0.05) with all sampling and anesthesia procedures except for JV-XKA and JV-MMF. Plasma NEFAs increased to 52% (P<0.05) with the TI-NA procedure and appeared to decrease with the JV-IA and JV-MMFA procedures (both Ps>0.05). Finally, only the JV-EA and the JV-MMFA procedures increased plasma corticosterone (+525 and +353%, respectively, both Ps< 0.05). The JV-IA and JV-XKA procedures appeared to increase it as well, but these differences did not reach statistical significance. Thus, anesthesia and blood sampling procedures can have profound acute effects on plasma metabolite and hormone concentrations. This must be considered for the design and interpretation of blood sampling experiments in laboratory animals. (c) 2010. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Lee, Deuk Yeon; Choi, Jae Hong; Shin, Jung Chul; Jung, Man Ki; Song, Seok Kyun; Suh, Jung Ki; Lee, Chang Young
2018-06-01
Compared with wet processes, dry functionalization using plasma is fast, scalable, solvent-free, and thus presents a promising approach for grafting functional groups to powdery nanomaterials. Previous approaches, however, had difficulties in maintaining an intimate sample-plasma contact and achieving uniform functionalization. Here, we demonstrate a plasma reactor equipped with a porous filter electrode that increases both homogeneity and degree of functionalization by capturing and circulating powdery carbon nanotubes (CNTs) via vacuum and gas blowing. Spectroscopic measurements verify that treatment with O2/air plasma generates oxygen-containing groups on the surface of CNTs, with the degree of functionalization readily controlled by varying the circulation number. Gas sensors fabricated using the plasma-treated CNTs confirm alteration of molecular adsorption on the surface of CNTs. A sequential treatment with NH3 plasma following the oxidation pre-treatment results in the functionalization with nitrogen species of up to 3.2 wt%. Our approach requiring no organic solvents not only is cost-effective and environmentally friendly, but also serves as a versatile tool that applies to other powdery micro or nanoscale materials for controlled modification of their surfaces.
Circulating DNA: a potential marker of sickle cell crisis.
Vasavda, Nisha; Ulug, Pinar; Kondaveeti, Sheila; Ramasamy, Karthik; Sugai, Taku; Cheung, Gordon; Rees, David C; Awogbade, Moji; Bannister, Sybil; Cunningham, Juliette; Menzel, Stephan; Thein, Swee Lay
2007-10-01
Free circulating DNA is present in the plasma of healthy subjects, and is elevated in conditions characterized by increased cell death, such as cancer and physical trauma. Analysis of circulating DNA in plasma could provide a useful biomarker in sickle cell disease (SCD) in view of the increased cell turnover through chronic ongoing haemolysis, recurrent vaso-occlusion and inflammation. Plasma DNA was determined by real-time quantitative polymerase chain reaction (PCR) amplification of the beta-globin gene (HBB) in 154 patients with SCD [105 haemoglobin (Hb)SS, 46 HbSC and three HbS/beta(0) thalassaemia] and 53 ethnically matched controls. Blood samples were obtained from all patients in steady state; 21 of the 154 patients were also sampled during admission to hospital for acute pain. Median concentration of circulating plasma DNA in acute pain was more than 10-fold that in steady state and in controls - 10070 vs. 841 and 10070 vs. 933 genome equivalents/ml respectively (P < 0.0001, in both cases). During steady state, patients had plasma DNA levels similar to controls. Plasma DNA levels in SCD correlated with C-reactive protein levels (P < 0.005) and total white cell counts (P < 0.05) in steady state. The study shows that plasma DNA concentration may have potential as a biomarker in sickle cell patients.
de Miguel, Dunia; Burgaleta, Carmen; Reyes, Eduardo; Pascual, Teresa
2003-07-01
We evaluated a new portable monitor (AvoSure PT PRO, Menarini Diagnostics, Firenze, Italy) developed to test the prothrombin time in capillary blood and plasma by comparing it with the standard laboratory determination. We studied 62 patients receiving acenocoumarol therapy. The international normalized ratio (INR) in capillary blood was analyzed by 2 methods: AvoSure PT PRO and Thrombotrack Nycomed Analyzer (Axis-Shield, Dundee, Scotland). Parallel studies were performed in plasma samples by a reference method using the Behring Coagulation Timer (Behring Diagnostics, Marburg, Germany). Plasma samples also were tested with the AvoSure PT PRO. Correlation was good for INR values for capillary blood and plasma samples by AvoSure PT PRO and our reference method (R2 = 0.8596) and for capillary blood samples tested by the AvoSure PT PRO and Thrombotrack Nycomed Analyzer (R2 = 0.8875). The correlation for INR in capillary blood and plasma samples by AvoSure PT PRO was 0.6939 (P < .0004). Capillary blood determinations are rapid and effective for monitoring oral anticoagulation therapy and have a high correlation to plasma determinations. AvoSure PT PRO is accurate for controlling INR in plasma and capillary blood samples, may be used in outpatient clinics, and has advantages over previous portable monitors.
Measurement by ICP-MS of lead in plasma and whole blood of lead workers and controls.
Schütz, A; Bergdahl, I A; Ekholm, A; Skerfving, S
1996-01-01
OBJECTIVES: To test a simple procedure for preparing samples for measurement of lead in blood plasma (P-Pb) and whole blood (B-Pb) by inductively coupled plasma mass spectrometry (ICP-MS), to measure P-Pb and B-Pb in lead workers and controls, and to evaluate any differences in the relation between B-Pb and P-Pb between people. METHODS: P-Pb and B-Pb were measured by ICP-MS in 43 male lead smelter workers and seven controls without occupational exposure to lead. For analysis, plasma and whole blood were diluted 1 in 4 and 1 in 9, respectively, with a diluted ammonia solution containing Triton-X 100 and EDTA. The samples were handled under routine laboratory conditions, without clean room facilities. RESULTS: P-Pb was measured with good precision (CV = 5%) even at concentrations present in the controls. Freeze storage of the samples had no effect on the results. The detection limit was 0.015 microgram/l. The P-Pb was 0.15 (range 0.1-0.3) microgram/l in controls and 1.2 (0.3-3.6) micrograms/l in lead workers, although the corresponding B-Pbs were 40 (24-59) micrograms/l and 281 (60-530) micrograms/l (1 microgram Pb/I = 4.8 nmol/l). B-Pb was closely associated with P-Pb (r = 0.90). The association was evidently non-linear; the ratio B-Pb/P-Pb decreased with increasing P-Pb. CONCLUSIONS: By means of ICP-MS and a simple dilution procedure, P-Pb may be measured accurately and with good precision down to concentrations present in controls. Contamination of blood at sampling and analysis is no major problem. With increasing P-Pb, the percentage of lead in plasma increases. In studies of lead toxicity, P-Pb should be considered as a complement to current indicators of lead exposure and risk. PMID:9038796
Plasma serotonin in horses undergoing surgery for small intestinal colic
Torfs, Sara C.; Maes, An A.; Delesalle, Catherine J.; Pardon, Bart; Croubels, Siska M.; Deprez, Piet
2015-01-01
This study compared serotonin concentrations in platelet poor plasma (PPP) from healthy horses and horses with surgical small intestinal (SI) colic, and evaluated their association with postoperative ileus, strangulation and non-survival. Plasma samples (with EDTA) from 33 horses with surgical SI colic were collected at several pre- and post-operative time points. Serotonin concentrations were determined using liquid-chromatography tandem mass spectrometry. Results were compared with those for 24 healthy control animals. The serotonin concentrations in PPP were significantly lower (P < 0.01) in pre- and post-operative samples from surgical SI colic horses compared to controls. However, no association with postoperative ileus or non-survival could be demonstrated at any time point. In this clinical study, plasma serotonin was not a suitable prognostic factor in horses with SI surgical colic. PMID:25694668
Quantitation of Human Papillomavirus DNA in Plasma of Oropharyngeal Carcinoma Patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cao Hongbin; Banh, Alice; Kwok, Shirley
Purpose: To determine whether human papillomavirus (HPV) DNA can be detected in the plasma of patients with HPV-positive oropharyngeal carcinoma (OPC) and to monitor its temporal change during radiotherapy. Methods and Materials: We used polymerase chain reaction to detect HPV DNA in the culture media of HPV-positive SCC90 and VU147T cells and the plasma of SCC90 and HeLa tumor-bearing mice, non-tumor-bearing controls, and those with HPV-negative tumors. We used real-time quantitative polymerase chain reaction to quantify the plasma HPV DNA in 40 HPV-positive OPC, 24 HPV-negative head-and-neck cancer patients and 10 non-cancer volunteers. The tumor HPV status was confirmed bymore » p16{sup INK4a} staining and HPV16/18 polymerase chain reaction or HPV in situ hybridization. A total of 14 patients had serial plasma samples for HPV DNA quantification during radiotherapy. Results: HPV DNA was detectable in the plasma samples of SCC90- and HeLa-bearing mice but not in the controls. It was detected in 65% of the pretreatment plasma samples from HPV-positive OPC patients using E6/7 quantitative polymerase chain reaction. None of the HPV-negative head-and-neck cancer patients or non-cancer controls had detectable HPV DNA. The pretreatment plasma HPV DNA copy number correlated significantly with the nodal metabolic tumor volume (assessed using {sup 18}F-deoxyglucose positron emission tomography). The serial measurements in 14 patients showed a rapid decline in HPV DNA that had become undetectable at radiotherapy completion. In 3 patients, the HPV DNA level had increased to a discernable level at metastasis. Conclusions: Xenograft studies indicated that plasma HPV DNA is released from HPV-positive tumors. Circulating HPV DNA was detectable in most HPV-positive OPC patients. Thus, plasma HPV DNA might be a valuable tool for identifying relapse.« less
Dumache, Raluca; Puiu, Maria; Motoc, Marilena; Vernic, Corina; Dumitrascu, Victor
2014-01-01
Prostate cancer (PCa) represents the most commonly diagnosed type of malignancy among men in Western European countries and the second cause of cancer-related deaths among men worldwide. Methylation of the CpG island has an important role in prostate carcinogenesis and progression. The purpose of the study was to analyse the diagnostic value of aberrant promoter hypermethylation of the gene for glutathione S-transferase P1 (GSTP1) in plasma DNA to discriminate between prostate cancer (PCa) and benign prostatic hyperplasia (BPH) patients by minimally invasive methods. Aberrant promoter hypermethylation was investigated in DNA isolated from plasma samples of 31 patients with diagnostic of PCa and 44 cancer-free males (control subjects). Extracted genomic DNA was bisulfite treated and analyzed using methylation-specific polymerase chain reaction (MS-PCR) technique. Hypermethylation of the GSTP1 gene was detected in plasma samples from 27 of 31 (92.86%) patients with PCa. Genomic DNA from plasma samples from the 44 controls without genitourinary cancer revealed promoter hypermethylation of GSTP1 gene in 3 (10.6%) of the 44 patients. Receiver operating curve (ROC) included clinico-pathological parameters such as: serum PSA levels, pathological stage, Gleason score, hypermethylation status of GSTP1 gene, and it gave a predictive accuracy of 93% with a sensitivity and specificity of 95% and 87%, respectively. In this study, we have evaluated the ability of GSTP1 gene to discriminate between PCa and BPH patients in genomic DNA from plasma samples by non-invasive methods.
Ring, P R; Bostick, J M
2000-04-01
A sensitive and selective high-performance liquid chromatography (HPLC) method was developed for the determination of zolpidem in human plasma. Zolpidem and the internal standard (trazodone) were extracted from human plasma that had been made basic. The basic sample was loaded onto a conditioned Bond Elut C18 cartridge, rinsed with water and eluted with methanol. Forty microliters were then injected onto the LC system. Separation was achieved on a C18 column (150 x 4.6 mm, 5 microm) with a mobile phase composed of acetonitrile:50 mM potassium phosphate monobasic at pH 6.0 (4:6, v/v). Detection was by fluorescence, with excitation at 254 nm and emission at 400 nm. The retention times of zolpidem and internal standard were approximately 4.7 and 5.3 min, respectively. The LC run time was 8 min. The assay was linear in concentration range 1-400 ng/ml for zolpidem in human plasma. The analysis of quality control samples for zolpidem (3, 30, and 300 ng/ml) demonstrated excellent precision with relative standard deviations (RSD) of 3.7, 4.6, and 3.0%, respectively (n = 18). The method was accurate with all intraday (n = 6) and overall (n = 18) mean concentrations within 5.8% from nominal at all quality control sample concentrations. This method was also performed using a Gilson Aspec XL automated sample processor and autoinjector. The samples were manually fortified with internal standard and made basic. The aspec then performed the solid phase extraction and made injections of the samples onto the LC system. Using the automated procedure for analysis, quality control samples for zolpidem (3, 30, and 300 ng/ml) demonstrated acceptable precision with RSD values of 9.0, 4.9, and 5.1%, respectively (n = 12). The method was accurate with all intracurve (n = 4) and overall (n = 12) mean values being less than 10.8% from nominal at all quality control sample concentrations.
Generation Scotland: Donor DNA Databank; A control DNA resource.
Kerr, Shona M; Liewald, David C M; Campbell, Archie; Taylor, Kerrie; Wild, Sarah H; Newby, David; Turner, Marc; Porteous, David J
2010-11-23
Many medical disorders of public health importance are complex diseases caused by multiple genetic, environmental and lifestyle factors. Recent technological advances have made it possible to analyse the genetic variants that predispose to complex diseases. Reliable detection of these variants requires genome-wide association studies in sufficiently large numbers of cases and controls. This approach is often hampered by difficulties in collecting appropriate control samples. The Generation Scotland: Donor DNA Databank (GS:3D) aims to help solve this problem by providing a resource of control DNA and plasma samples accessible for research. GS:3D participants were recruited from volunteer blood donors attending Scottish National Blood Transfusion Service (SNBTS) clinics across Scotland. All participants gave full written consent for GS:3D to take spare blood from their normal donation. Participants also supplied demographic data by completing a short questionnaire. Over five thousand complete sets of samples, data and consent forms were collected. DNA and plasma were extracted and stored. The data and samples were unlinked from their original SNBTS identifier number. The plasma, DNA and demographic data are available for research. New data obtained from analysis of the resource will be fed back to GS:3D and will be made available to other researchers as appropriate. Recruitment of blood donors is an efficient and cost-effective way of collecting thousands of control samples. Because the collection is large, subsets of controls can be selected, based on age range, gender, and ethnic or geographic origin. The GS:3D resource should reduce time and expense for investigators who would otherwise have had to recruit their own controls.
Palfi, M; Berg, S; Ernerudh, J; Berlin, G
2001-03-01
Transfusion-related acute lung injury (TRALI) and other posttransfusion reactions may be caused by granulocyte and/or HLA antibodies, which are often present in blood from multiparous donors. The purpose of this study was to compare the effects of plasma from multiparous donors with those of plasma from donors with no history of transfusion or pregnancy (control plasma) in a prospective, randomized, double-blind, crossover study. Intensive care patients, judged to need at least 2 units of plasma, were randomly assigned to receive a unit of control plasma and, 4 hours later, a plasma unit from a multiparous donor (> or = 3 live births) or to receive the plasma units in opposite order. The patients were closely monitored, and body temperature, blood pressure, and heart rate were recorded. Blood samples for analysis of blood gases, TNFalpha, IL-1 receptor antagonist, soluble E selectin, and C3d complement factor were collected at least on four occasions (before and after the transfusion of each unit). Transfusion of plasma from multiparous donors was associated with significantly lower oxygen saturation and higher TNFalpha concentrations than transfusion of control plasma. The mean arterial pressure increased significantly after the transfusion of control plasma, whereas plasma from multiparous donors had no effect on it. Five posttransfusion reactions were observed in 100 patients, in four cases after the transfusion of plasma from multiparous donors. Plasma from multiparous blood donors may impair pulmonary function in intensive care unit patients.
ERIC Educational Resources Information Center
Scanlan, Aaron T.; Richter-Stretton, Gina L.; Madueno, Maria C.; Borges, Nattai R.; Fenning, Andrew S.
2017-01-01
Measurement of plasma osmolality (P[subscript osm]) remains popular for assessing hydration status in exercise science. However, a controlled reliability assessment of micro-osmometry using small sample volumes to measure Posm remains to be performed. This study aimed to examine the reliability of a cryoscopic micro-osmometer requiring 15-µL…
Leb, Victoria; Stöcher, Markus; Valentine-Thon, Elizabeth; Hölzl, Gabriele; Kessler, Harald; Stekel, Herbert; Berg, Jörg
2004-02-01
We report on the development of a fully automated real-time PCR assay for the quantitative detection of hepatitis B virus (HBV) DNA in plasma with EDTA (EDTA plasma). The MagNA Pure LC instrument was used for automated DNA purification and automated preparation of PCR mixtures. Real-time PCR was performed on the LightCycler instrument. An internal amplification control was devised as a PCR competitor and was introduced into the assay at the stage of DNA purification to permit monitoring for sample adequacy. The detection limit of the assay was found to be 200 HBV DNA copies/ml, with a linear dynamic range of 8 orders of magnitude. When samples from the European Union Quality Control Concerted Action HBV Proficiency Panel 1999 were examined, the results were found to be in acceptable agreement with the HBV DNA concentrations of the panel members. In a clinical laboratory evaluation of 123 EDTA plasma samples, a significant correlation was found with the results obtained by the Roche HBV Monitor test on the Cobas Amplicor analyzer within the dynamic range of that system. In conclusion, the newly developed assay has a markedly reduced hands-on time, permits monitoring for sample adequacy, and is suitable for the quantitative detection of HBV DNA in plasma in a routine clinical laboratory.
Opioid Concentrations in Oral Fluid and Plasma in Cancer Patients With Pain.
Heiskanen, Tarja; Langel, Kaarina; Gunnar, Teemu; Lillsunde, Pirjo; Kalso, Eija A
2015-10-01
Measuring opioid concentrations in pain treatment is warranted in situations where optimal opioid analgesia is difficult to reach. To assess the usefulness of oral fluid (OFL) as an alternative to plasma in opioid concentration monitoring in cancer patients on chronic opioid therapy. We collected OFL and plasma samples from 64 cancer patients on controlled-release (CR) oral morphine, CR oral oxycodone, or transdermal (TD) fentanyl for pain. Samples were obtained on up to five separate days. A total of 213 OFL and plasma samples were evaluable. All patients had detectable amounts of the CR or TD opioid in both plasma and OFL samples. The plasma concentrations of oxycodone and fentanyl (determination coefficient R(2) = 0.628 and 0.700, respectively), but not morphine (R(2) = 0.292), were moderately well correlated to the daily opioid doses. In contrast to morphine and fentanyl (mean OFL/plasma ratio 2.0 and 3.0, respectively), the OFL oxycodone concentrations were significantly higher than the respective plasma concentrations (mean OFL/plasma ratio 14.9). An active transporter could explain the much higher OFL vs. plasma concentrations of oxycodone compared with morphine and fentanyl. OFL analysis is well suited for detecting the studied opioids. For morphine and fentanyl, an approximation of the plasma opioid concentrations is obtainable, whereas for oxycodone, the OFL/plasma concentration relationship is too variable for reliable approximation results. Copyright © 2015 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.
Ion sampling and transport in Inductively Coupled Plasma Mass Spectrometry
NASA Astrophysics Data System (ADS)
Farnsworth, Paul B.; Spencer, Ross L.
2017-08-01
Quantitative accuracy and high sensitivity in inductively coupled plasma mass spectrometry (ICP-MS) depend on consistent and efficient extraction and transport of analyte ions from an inductively coupled plasma to a mass analyzer, where they are sorted and detected. In this review we examine the fundamental physical processes that control ion sampling and transport in ICP-MS and compare the results of theory and computerized models with experimental efforts to characterize the flow of ions through plasma mass spectrometers' vacuum interfaces. We trace the flow of ions from their generation in the plasma, into the sampling cone, through the supersonic expansion in the first vacuum stage, through the skimmer, and into the ion optics that deliver the ions to the mass analyzer. At each stage we consider idealized behavior and departures from ideal behavior that affect the performance of ICP-MS as an analytical tool.
Plasma of argon enhances the adhesion of murine osteoblasts on different graft materials.
Canullo, Luigi; Genova, Tullio; Naenni, Nadja; Nakajima, Yasushi; Masuda, Katsuhiko; Mussano, Federico
2018-04-25
plasma of argon treatment was demonstrated to increase material surface energy leading to stronger and faster interaction with cells. The aim of the present in vitro study was to test the effect of plasma treatment on different graft materials. synthetic hydroxyapatite (Mg-HA), biphasic calcium phosphate (BCP), cancellous and cortical xenogeneic bone matrices (CaBM, CoBM) were used representing commonly used classes of bone substitute materials. Fifty serially numbered disks with a 10mm-diameter from each graft material were randomly divided into two groups: Test group (argon plasma treatment) and Control group (absence of treatment). Cell morphology (using pre-osteoblastic murine cells) and protein adsorption were analyzed at all samples from both the test and control group. Differences between groups were analyzed using the Mann-Whitney test setting the level of significance at p<0.05. plasma treatment significantly increased the protein adsorption at all samples. Similarly, plasma treatment significantly increased cell adhesion in all groups. data confirmed that non-atmospheric plasma of argon treatment led to an increase of protein adsorption and cell adhesion in all groups of graft material to a similar extent. plasma of argon is able to improve the surface conditions of graft materials. Copyright © 2018 Elsevier GmbH. All rights reserved.
KRAS mutations in blood circulating cell-free DNA: a pancreatic cancer case-control
Le Calvez-Kelm, Florence; Foll, Matthieu; Wozniak, Magdalena B.; Delhomme, Tiffany M.; Durand, Geoffroy; Chopard, Priscilia; Pertesi, Maroulio; Fabianova, Eleonora; Adamcakova, Zora; Holcatova, Ivana; Foretova, Lenka; Janout, Vladimir; Vallee, Maxime P.; Rinaldi, Sabina; Brennan, Paul; McKay, James D.; Byrnes, Graham B.; Scelo, Ghislaine
2016-01-01
The utility of KRAS mutations in plasma circulating cell-free DNA (cfDNA) samples as non-invasive biomarkers for the detection of pancreatic cancer has never been evaluated in a large case-control series. We applied a KRAS amplicon-based deep sequencing strategy combined with analytical pipeline specifically designed for the detection of low-abundance mutations to screen plasma samples of 437 pancreatic cancer cases, 141 chronic pancreatitis subjects, and 394 healthy controls. We detected mutations in 21.1% (N=92) of cases, of whom 82 (89.1%) carried at least one mutation at hotspot codons 12, 13 or 61, with mutant allelic fractions from 0.08% to 79%. Advanced stages were associated with an increased proportion of detection, with KRAS cfDNA mutations detected in 10.3%, 17,5% and 33.3% of cases with local, regional and systemic stages, respectively. We also detected KRAS cfDNA mutations in 3.7% (N=14) of healthy controls and in 4.3% (N=6) of subjects with chronic pancreatitis, but at significantly lower allelic fractions than in cases. Combining cfDNA KRAS mutations and CA19-9 plasma levels on a limited set of case-control samples did not improve the overall performance of the biomarkers as compared to CA19-9 alone. Whether the limited sensitivity and specificity observed in our series of KRAS mutations in plasma cfDNA as biomarkers for pancreatic cancer detection are attributable to methodological limitations or to the biology of cfDNA should be further assessed in large case-control series. PMID:27705932
Evaluation of random plasma glucose for assessment of glycaemic control in type 2 diabetes mellitus.
Ain, Qurratul; Latif, Atif; Jaffar, Syed Raza; Ijaz, Aamir
2017-09-01
To evaluate the accuracy of random plasma glucose in outpatients with type 2 diabetes mellitus for assessing glycaemic control. This comparative, cross-sectional study was conducted at the chemical pathology department of PNS Shifa Hospital, Karachi, from August 2015 to March 2016, and comprised data of subjects with type 2 diabetes mellitus who reported for evaluation of glycaemic control in non-fasting state. All blood samples were analysed for random plasma glucose and glycated haemoglobin. Random plasma glucose was compared as an index test with glycated haemoglobin considering it as reference standard at a value of less than 7% for good glycaemic control. SPSS 20 was used for data analysis. Of the 222 subjects, 93(42%) had good glycaemic control. Random plasma glucose showed strong positive correlation with glycated haemoglobin (p=0.000).Area under curve for random plasma glucose as determined by plotting receiver operating characteristic curve against glycated haemoglobin value of 7% was 0.89 (95% confidence interval: 0.849-0.930). Random plasma glucose at cut-off value of 150 mg/dl was most efficient for ruling out poor glycaemic control among patients with type 2 diabetes mellitus with 90.7% sensitivity and69.9% specificity and Youden's index of 0.606. Random plasma glucose may be used to reflect glycaemic control in adults with type 2 diabetes mellitus in areas where glycated haemoglobin is not feasible.
Doescher, Andrea; Petershofen, Eduard K; Wagner, Franz F; Schunter, Markus; Müller, Thomas H
2013-02-01
Determination of fetal blood groups in maternal plasma samples critically depends on adequate amplification of fetal DNA. We evaluated the routine inclusion of 52 single-nucleotide polymorphisms (SNPs) as internal reference in our polymerase chain reaction (PCR) settings to obtain a positive internal control for fetal DNA. DNA from 223 plasma samples of pregnant women was screened for RHD Exons 3, 4, 5, and 7 in a multiplex PCR including 52 SNPs divided into four primer pools. Amplicons were analyzed by single-base extension and the GeneScan method in a genetic analyzer. Results of D screening were compared to standard RHD genotyping of amniotic fluid or real-time PCR of fetal DNA from maternal plasma. The vast majority of all samples (97.8%) demonstrated differences in maternal and fetal SNP patterns when tested with four primer pools. These differences were not observed in less than 2.2% of the samples most probably due to an extraction failure for adequate amounts of fetal DNA. Comparison of the fetal genotypes with independent results did not reveal a single false-negative case among samples (n = 42) with positive internal control and negative fetal RHD typing. Coamplification of 52 SNPs with RHD-specific sequences for fetal blood group determination introduces a valid positive control for the amplification of fetal DNA to avoid false-negative results. This new approach does not require a paternal blood sample. It may also be applicable to other assays for fetal genotyping in maternal blood samples. © 2012 American Association of Blood Banks.
Investigation of Metabolomic Blood Biomarkers for Detection of Adenocarcinoma Lung Cancer
Fahrmann, Johannes F.; Kim, Kyoungmi; DeFelice, Brian C.; Taylor, Sandra L.; Gandara, David R.; Yoneda, Ken Y.; Cooke, David T.; Fiehn, Oliver; Kelly, Karen; Miyamoto, Suzanne
2015-01-01
Background Untargeted metabolomics was utilized in case control studies of adenocarcinoma (ADC) lung cancer in order to develop and test metabolite classifiers in serum and plasma as potential biomarkers for diagnosing lung cancer. Methods Serum and plasma were collected and used in two independent case-control studies (ADC1 and ADC2). Controls were frequency matched for gender, age and smoking history. There were 52 ADC cases and 31 controls in ADC1 and 43 ADC cases and 43 controls in ADC2. Metabolomics was conducted using gas chromatography time-of-flight mass spectrometry. Differential analysis was performed on ADC1 and the top candidates (FDR < 0.05) for serum and plasma used to develop individual and multiplex-classifiers that were then tested on an independent set of serum and plasma samples (ADC2). Results Aspartate provided the best accuracy (81.4%) for an individual metabolite classifier in serum whereas pyrophosphate had the best accuracy (77.9%) in plasma when independently tested. Multiplex classifiers of either 2 or 4 serum metabolites had an accuracy of 72.7% when independently tested. For plasma, a multi-metabolite classifier consisting of 8 metabolites gave an accuracy of 77.3% when independently tested. Comparison of overall diagnostic performance between the two blood matrices yielded similar performances. However, serum is most ideal given higher sensitivity for low abundant metabolites. Conclusion This study shows the potential of metabolite-based diagnostic tests for detection of lung adenocarcinoma. Further validation in a larger pool of samples is warranted. Impact These biomarkers could improve early detection and diagnosis of lung cancer. PMID:26282632
NASA Astrophysics Data System (ADS)
Ogruc Ildiz, G.; Arslan, M.; Unsalan, O.; Araujo-Andrade, C.; Kurt, E.; Karatepe, H. T.; Yilmaz, A.; Yalcinkaya, O. B.; Herken, H.
2016-01-01
In this study, a methodology based on Fourier-transform infrared spectroscopy and principal component analysis and partial least square methods is proposed for the analysis of blood plasma samples in order to identify spectral changes correlated with some biomarkers associated with schizophrenia and bipolarity. Our main goal was to use the spectral information for the calibration of statistical models to discriminate and classify blood plasma samples belonging to bipolar and schizophrenic patients. IR spectra of 30 samples of blood plasma obtained from each, bipolar and schizophrenic patients and healthy control group were collected. The results obtained from principal component analysis (PCA) show a clear discrimination between the bipolar (BP), schizophrenic (SZ) and control group' (CG) blood samples that also give possibility to identify three main regions that show the major differences correlated with both mental disorders (biomarkers). Furthermore, a model for the classification of the blood samples was calibrated using partial least square discriminant analysis (PLS-DA), allowing the correct classification of BP, SZ and CG samples. The results obtained applying this methodology suggest that it can be used as a complimentary diagnostic tool for the detection and discrimination of these mental diseases.
Discordant CSF/plasma HIV-1 RNA in patients with unexplained low-level viraemia.
Nightingale, Sam; Geretti, Anna Maria; Beloukas, Apostolos; Fisher, Martin; Winston, Alan; Else, Laura; Nelson, Mark; Taylor, Stephen; Ustianowski, Andrew; Ainsworth, Jonathan; Gilson, Richard; Haddow, Lewis; Ong, Edmund; Watson, Victoria; Leen, Clifford; Minton, Jane; Post, Frank; Pirmohamed, Munir; Solomon, Tom; Khoo, Saye
2016-12-01
The central nervous system has been proposed as a sanctuary site where HIV can escape antiretroviral control and develop drug resistance. HIV-1 RNA can be at higher levels in CSF than plasma, termed CSF/plasma discordance. We aimed to examine whether discordance in CSF is associated with low level viraemia (LLV) in blood. In this MRC-funded multicentre study, we prospectively recruited patients with LLV, defined as one or more episode of unexplained plasma HIV-1 RNA within 12 months, and undertook CSF examination. Separately, we prospectively collected CSF from patients undergoing lumbar puncture for a clinical indication. Patients with durable suppression of viraemia and no evidence of CNS infection were identified as controls from this group. Factors associated with CSF/plasma HIV-1 discordance overall were examined. One hundred fifty-three patients were recruited across 13 sites; 40 with LLV and 113 undergoing clinical lumbar puncture. Seven of the 40 (18 %) patients with LLV had CSF/plasma discordance, which was significantly more than 0/43 (0 %) with durable suppression in blood from the clinical group (p = 0.005). Resistance associated mutations were shown in six CSF samples from discordant patients with LLV (one had insufficient sample for testing), which affected antiretroviral therapy at sampling in five. Overall discordance was present in 20/153 (13 %) and was associated with nadir CD4 but not antiretroviral concentrations in plasma or CSF. CSF/plasma discordance is observed in patients with LLV and is associated with antiretroviral resistance associated mutations in CSF. The implications for clinical practice require further investigation.
Morris, Angela D; McCombs, Gayle B; Akan, Tamer; Hynes, Wayne; Laroussi, Mounir; Tolle, Susan L
2009-01-01
Cold plasma, also known as Low Temperature Atmospheric Pressure Plasma (LTAPP) is a novel technology consisting of neutral and charged particles, including free radicals, which can be used to destroy or inactivate microorganisms. Research has been conducted regarding the effect of cold plasma on gram-positive bacteria; however, there is limited research regarding its ability to inactivate the spore-formers Geobacillus stearothermophilus and Bacillus cereus. The purpose of this study was to determine if cold plasma inactivates G. stearothermophilus and B. cereus vegetative cells and spores. Nine hundred eighty-one samples were included in this study (762 experimental and 219 controls). Experimental samples were exposed indirectly or directly to cold plasma, before plating and incubating for 16 hours. Control samples were not exposed to cold plasma. The percentage-kill and cell number reductions were calculated from Colony Forming Units (CFU). Data were statistically analyzed at the .05 level using one-way ANOVA, Kruskal Wallis and Tukey's tests. There was a statistically significant difference in the inactivation of G. stearothermophilus vegetative cells receiving indirect and direct exposure (p=0.0001 and p=0.0013, respectively), as well as for B. cereus vegetative cells and spores (p=0.0001 for direct and indirect). There was no statistically significant difference in the inactivation of G. stearothermophilus spores receiving indirect exposure (p=0.7208) or direct exposure (p=0.0835). Results demonstrate that cold plasma exposure effectively kills G. stearothermophilus vegetative cells and B. cereus vegetative cells and spores; however, G. stearothermophilus spores were not significantly inactivated.
Measurement of Phenolic Environmental Estrogens in Women with Uterine Leiomyoma
Shen, Yang; Xu, Qian; Ren, Mulan; Feng, Xu; Cai, Yunlang; Gao, Yongxing
2013-01-01
Objectives To investigate the effect of phenolic environmental estrogens on uterine leiomyoma from the perspective of clinical epidemiology. Methods Urine and blood samples were collected from Han women with uterine leiomyoma and women without uterine leiomyoma, living in Nanjing, China, between September 2011 and February 2013. A total of 156 urine samples and 214 blood samples were collected from the uterine leiomyoma group and 106 urine samples and 126 blood plasma samples from the control group. Bisphenol A (BPA), nonylphenol (NP) and octylphenol (OP) concentrations were determined by solid-phase extraction (SPE) coupled with liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). Results Phenolic environmental estrogens in the uterine leiomyoma and control groups were compared based on: gravida>3 and gravida ≤ 3. In participants with gravida>3, urine OP concentration was significantly (P<0.05) higher in the uterine leiomyoma group than in the control group. In participants with gravida ≤ 3, urine NP concentration was significantly (P<0.05) higher in the uterine leiomyoma group compared to controls. Despite obstetric history, urine BPA mean exposure concentration was significantly (P<0.05) different between uterine leiomyoma group and control group. The urine BPA concentration was not significantly (P>0.05) different between gravida>3 and gravida ≤ 3 patients. There was no significant (P>0.05) difference in plasma concentrations of BPA, OP and NP between the leiomyoma group and control group. Mean exposure concentration and range of distribution of BPA, OP and NP plasma concentration differed between the uterine leiomyoma and control group. Conclusion Exposure level of phenolic environmental estrogens in human was related with leiomyoma tumorigenesis. PMID:24255718
Sensitive Detection of Colorectal Cancer in Peripheral Blood by Septin 9 DNA Methylation Assay
Grützmann, Robert; Molnar, Bela; Pilarsky, Christian; Habermann, Jens K.; Schlag, Peter M.; Saeger, Hans D.; Miehlke, Stephan; Stolz, Thomas; Model, Fabian; Roblick, Uwe J.; Bruch, Hans-Peter; Koch, Rainer; Liebenberg, Volker; deVos, Theo; Song, Xiaoling; Day, Robert H.; Sledziewski, Andrew Z.; Lofton-Day, Catherine
2008-01-01
Background Colorectal cancer (CRC) is the second leading cause of cancer deaths despite the fact that detection of this cancer in early stages results in over 90% survival rate. Currently less than 45% of at-risk individuals in the US are screened regularly, exposing a need for better screening tests. We performed two case-control studies to validate a blood-based test that identifies methylated DNA in plasma from all stages of CRC. Methodology/Principal Findings Using a PCR assay for analysis of Septin 9 (SEPT9) hypermethylation in DNA extracted from plasma, clinical performance was optimized on 354 samples (252 CRC, 102 controls) and validated in a blinded, independent study of 309 samples (126 CRC, 183 controls). 168 polyps and 411 additional disease controls were also evaluated. Based on the training study SEPT9-based classification detected 120/252 CRCs (48%) and 7/102 controls (7%). In the test study 73/126 CRCs (58%) and 18/183 control samples (10%) were positive for SEPT9 validating the training set results. Inclusion of an additional measurement replicate increased the sensitivity of the assay in the testing set to 72% (90/125 CRCs detected) while maintaining 90% specificity (19/183 for controls). Positive rates for plasmas from the other cancers (11/96) and non-cancerous conditions (41/315) were low. The rate of polyp detection (>1 cm) was ∼20%. Conclusions/Significance Analysis of SEPT9 DNA methylation in plasma represents a straightforward, minimally invasive method to detect all stages of CRC with potential to satisfy unmet needs for increased compliance in the screening population. Further clinical testing is warranted. PMID:19018278
Mills, L J; Gutjahr-Gobell, R E; Haebler, R A; Horowitz, D J; Jayaraman, S; Pruell, R J; McKinney, R A; Gardner, G R; Zaroogian, G E
2001-04-01
Laboratory experiments were conducted with male summer flounder to assess the value of selected measures of endocrine status in fish as indicators of exposure to endocrine-disrupting contaminants. Effects of 1,1,1-trichloro-2-(p-chlorophenyl)-2-(o-chlorophenyl) ethane (o,p'-DDT), octylphenol and 1,1-dichloro-2,2-bis (p-chlorophenyl) ethylene (p,p'-DDE) on hepatosomatic and gonadosomatic indices, plasma steroid hormone levels, vitellogenin production, and gonadal development were evaluated in laboratory-raised, juvenile male summer flounder. Flounder were injected twice with test chemical in a coconut oil carrier. Each chemical was tested at three different concentrations. Estrogenic (o,p'-DDT; octylphenol) and anti-androgenic (p,p'-DDE) chemicals were evaluated alone and in combination (octylphenol plus o,p'-DDT or p,p'-DDE). Additionally, some fish were treated with the natural ligand for the estrogen receptor, 17beta-estradiol. Blood and tissues from different fish in each treatment were sampled 4, 6 and 8 weeks after the first injection. Fish exposed to a combination of o,p'-DDT plus octylphenol were also sampled after 15 weeks. In all cases, responses of fish exposed to a test chemical were compared to control fish sampled at the same time. The following significant differences, relative to controls, were observed in at least one sampling time or at least one concentration of chemical. 17beta-Estradiol-treated flounder exhibited decreased gonadosomatic index (GSI), altered hepatosomatic index (HSI), elevated plasma estradiol, reduced plasma testosterone, and high levels of plasma vitellogenin. Fish treated with o,p'-DDT showed lower GSI, no change in HSI or plasma estradiol, depression of plasma testosterone, and induction of vitellogenesis. Octylphenol treatment resulted in lower GSI, no change in HSI, initially increased plasma estradiol and decreased testosterone, and no vitellogenin production. p,p'-DDE treatment did not significantly alter any indicator relative to controls. In experiments using combinations of chemicals, flounder receiving o,p'-DDT plus octylphenol had lower GSI after 8 weeks and elevated plasma estradiol after 15 weeks exposure. Fish treated with p,p'-DDE plus octylphenol for 8 weeks exhibited a significantly lower GSI. Overall, lower GSI and plasma testosterone levels, relative to controls, were consistent indicators of exposure to estrogenic chemicals in juvenile male flounder. No indicators were found that would identify exposure to the mammalian anti-androgen p,p'-DDE.
Interlaboratory trial for the measurement of total cobalt in equine urine and plasma by ICP-MS.
Popot, Marie-Agnes; Ho, Emmie N M; Stojiljkovic, Natali; Bagilet, Florian; Remy, Pierre; Maciejewski, Pascal; Loup, Benoit; Chan, George H M; Hargrave, Sabine; Arthur, Rick M; Russo, Charlie; White, James; Hincks, Pamela; Pearce, Clive; Ganio, George; Zahra, Paul; Batty, David; Jarrett, Mark; Brooks, Lydia; Prescott, Lise-Anne; Bailly-Chouriberry, Ludovic; Bonnaire, Yves; Wan, Terence S M
2017-09-01
Cobalt is an essential mineral micronutrient and is regularly present in equine nutritional and feed supplements. Therefore, cobalt is naturally present at low concentrations in biological samples. The administration of cobalt chloride is considered to be blood doping and is thus prohibited. To control the misuse of cobalt, it was mandatory to establish an international threshold for cobalt in plasma and/or in urine. To achieve this goal, an international collaboration, consisting of an interlaboratory comparison between 5 laboratories for the urine study and 8 laboratories for the plasma study, has been undertaken. Quantification of cobalt in the biological samples was performed by inductively coupled plasma-mass spectrometry (ICP-MS). Ring tests were based on the analysis of 5 urine samples supplemented at concentrations ranging from 5 up to 500 ng/mL and 5 plasma samples spiked at concentrations ranging from 0.5 up to 25 ng/mL. The results obtained from the different laboratories were collected, compiled, and compared to assess the reproducibility and robustness of cobalt quantification measurements. The statistical approach for the ring test for total cobalt in urine was based on the determination of percentage deviations from the calculated means, while robust statistics based on the calculated median were applied to the ring test for total cobalt in plasma. The inter-laboratory comparisons in urine and in plasma were successful so that 97.6% of the urine samples and 97.5% of the plasma samples gave satisfactory results. Threshold values for cobalt in plasma and urine were established from data only obtained by laboratories involved in the ring test. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Keping, YAN; Qikang, JIN; Chao, ZHENG; Guanlei, DENG; Shengyong, YIN; Zhen, LIU
2018-04-01
This paper presents plasma-induced blood coagulation and its pilot application in rat hepatectomy by using a home-made pulsed cold plasma jet. Experiments were conducted on blood coagulation in vitro, the influence of plasma on tissue in vivo, and the pilot application of rat hepatectomy. Experimental results show that the cold plasma can lead to rapid blood coagulation. Compared with the control sample, the plasma-induced agglomerated layer of blood is thicker and denser, and is mostly composed of broken platelets. When the surface of the liver was treated by plasma, the influence of the plasma can penetrate into the liver to a depth of about 500 μm. During the rat hepatectomy, cold plasma was proved to be effective for stanching bleeding on incision. No obvious bleeding was found in the abdominal cavities of all six rats 48 h after the hepatectomy. This implies that cold plasma can be an effective modality to control bleeding during surgical operation.
Metz, Thomas O.; Qian, Wei-Jun; Jacobs, Jon M.; Gritsenko, Marina A.; Moore, Ronald J.; Polpitiya, Ashoka D.; Monroe, Matthew E.; Camp, David G.; Mueller, Patricia W.; Smith, Richard D.
2009-01-01
Novel biomarkers of type 1 diabetes must be identified and validated in initial, exploratory studies before they can be assessed in proficiency evaluations. Currently, untargeted “-omics” approaches are under-utilized in profiling studies of clinical samples. This report describes the evaluation of capillary liquid chromatography (LC) coupled with mass spectrometry (MS) in a pilot proteomic analysis of human plasma and serum from a subset of control and type 1 diabetic individuals enrolled in the Diabetes Autoantibody Standardization Program with the goal of identifying candidate biomarkers of type 1 diabetes. Initial high-resolution capillary LC-MS/MS experiments were performed to augment an existing plasma peptide database, while subsequent LC-FTICR studies identified quantitative differences in the abundance of plasma proteins. Analysis of LC-FTICR proteomic data identified five candidate protein biomarkers of type 1 diabetes. Alpha-2-glycoprotein 1 (zinc), corticosteroid-binding globulin, and lumican were 2-fold up-regulated in type 1 diabetic samples relative to control samples, whereas clusterin and serotransferrin were 2-fold up-regulated in control samples relative to type 1 diabetic samples. Observed perturbations in the levels of all five proteins are consistent with the metabolic aberrations found in type 1 diabetes. While the discovery of these candidate protein biomarkers of type 1 diabetes is encouraging, follow up studies are required for validation in a larger population of individuals and for determination of laboratory-defined sensitivity and specificity values using blinded samples. PMID:18092746
Metz, Thomas O; Qian, Wei-Jun; Jacobs, Jon M; Gritsenko, Marina A; Moore, Ronald J; Polpitiya, Ashoka D; Monroe, Matthew E; Camp, David G; Mueller, Patricia W; Smith, Richard D
2008-02-01
Novel biomarkers of type 1 diabetes must be identified and validated in initial, exploratory studies before they can be assessed in proficiency evaluations. Currently, untargeted "-omics" approaches are underutilized in profiling studies of clinical samples. This report describes the evaluation of capillary liquid chromatography (LC) coupled with mass spectrometry (MS) in a pilot proteomic analysis of human plasma and serum from a subset of control and type 1 diabetic individuals enrolled in the Diabetes Autoantibody Standardization Program, with the goal of identifying candidate biomarkers of type 1 diabetes. Initial high-resolution capillary LC-MS/MS experiments were performed to augment an existing plasma peptide database, while subsequent LC-FTICR studies identified quantitative differences in the abundance of plasma proteins. Analysis of LC-FTICR proteomic data identified five candidate protein biomarkers of type 1 diabetes. alpha-2-Glycoprotein 1 (zinc), corticosteroid-binding globulin, and lumican were 2-fold up-regulated in type 1 diabetic samples relative to control samples, whereas clusterin and serotransferrin were 2-fold up-regulated in control samples relative to type 1 diabetic samples. Observed perturbations in the levels of all five proteins are consistent with the metabolic aberrations found in type 1 diabetes. While the discovery of these candidate protein biomarkers of type 1 diabetes is encouraging, follow up studies are required for validation in a larger population of individuals and for determination of laboratory-defined sensitivity and specificity values using blinded samples.
Related factors to disparity of diabetes care in Iran.
Mirzazadeh, Ali; Baradaran, Hamid R; Haghdoost, Ali A; Salari, Pooria
2009-05-01
We determined, in Iranian patients with diabetes mellitus, the prevalence of inadequate glycemic control and its predictors. The data from a national population-based survey that included a random sample of 89 404 Iranian individuals in 2005 were analyzed. In that sample, 2923 diabetic subjects (age range, 25-64 years) were identified. We linked the results of their fasting plasma glucose levels with demographic and behavioral variables to determine predictors of poor glycemic control. About 57% of the subjects had a fasting plasma glucose level of > or =130 mg/dL. That percentage was comparable in male and female subjects and in literate and illiterate subjects. However, inhabitants in rural areas controlled their fasting plasma glucose level about 11% better than did subjects who lived in an urban area. We also found that control of the fasting plasma glucose level was much better in relatively younger diabetic patients. Diabetic subjects with a family history of type 2 diabetes mellitus exhibited a higher uncontrolled fasting plasma glucose level than those without positive family history of diabetes. The percentage of uncontrolled type 2 diabetes found in our study suggests that the Iranian healthcare system should devote more attention to that disorder, particularly in elderly individuals, who are more vulnerable to the complications of diabetes and control their disorder less well than do younger diabetic patients. The recent integration of diabetic care in primary healthcare systems in Iranian rural areas was found to have a promising effect on community health.
Hoge, EA; Lawson, EA; Metcalf, CA; Keshaviah, A; Zak, PJ; Pollack, MH; Simon, NM
2013-01-01
Background Generalized Social Anxiety Disorder (GSAD) is characterized by excessive fear and avoidance of several types of social and performance situations. The pathophysiology is not well understood, but research in animals and humans has provided evidence that oxytocin helps regulate normal social affiliative behavior. Previous work in healthy male subjects demonstrated a rise in plasma oxytocin after receiving a high trust signal. To examine the oxytocin system in GSAD, we measured plasma oxytocin in GSAD patients and controls, before and after the social “Trust Game,” a neuroeconomic test examining trust behavior and reaction to trust using real monetary incentives. Methods Thirty-nine subjects with GSAD and 28 healthy controls provided three blood samples for oxytocin measurement before the Trust Game, and one sample after the game. Plasma estradiol was also measured at baseline. The Trust Game protocol version prioritized the sending of a signal of high cooperation and trust to all participants. All analyses controlled for gender and estradiol levels. Results Mean oxytocin levels post-Trust Game (p=0.025), and overall (area under the curve, p=0.011) were lower in GSAD patients compared to controls, after controlling for sex and estradiol. There was no significant change in oxytocin levels after the Game in either group. Conclusions We report low plasma oxytocin levels in patients with generalized social anxiety disorder during a pro-social laboratory task paradigm. Additional research will be important to further examine the relationship between oxytocin and social behavior in GSAD. PMID:22807189
Hoge, Elizabeth A; Lawson, Elizabeth A; Metcalf, Christina A; Keshaviah, Aparna; Zak, Paul J; Pollack, Mark H; Simon, Naomi M
2012-11-01
Generalized Social Anxiety Disorder (GSAD) is characterized by excessive fear and avoidance of several types of social and performance situations. The pathophysiology is not well understood, but research in animals and humans has provided evidence that oxytocin helps regulate normal social affiliative behavior. Previous work in healthy male subjects demonstrated a rise in plasma oxytocin after receiving a high trust signal. To examine the oxytocin system in GSAD, we measured plasma oxytocin in GSAD patients and controls, before and after the social "Trust Game," a neuroeconomic test examining trust behavior and reaction to trust using real monetary incentives. Thirty-nine subjects with GSAD and 28 healthy controls provided three blood samples for oxytocin measurement before the Trust Game, and one sample after the game. Plasma estradiol was also measured at baseline. The Trust Game protocol version prioritized the sending of a signal of high cooperation and trust to all participants. All analyses controlled for gender and estradiol levels. Mean oxytocin levels post-Trust Game (P = .025), and overall (area under the curve, P = .011) were lower in GSADpatients compared to controls, after controlling for sex and estradiol. There was no significant change in oxytocin levels after the game in either group. We report low plasma oxytocin levels in patients with GSAD during a prosocial laboratory task paradigm. Additional research will be important to further examine the relationship between oxytocin and social behavior in GSAD. © 2012 Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
Convertino, V. A.; Benjamin, B. A.; Keil, L. C.; Sandler, H.
1984-01-01
Hemodynamic responses and antidiuretic hormone (ADH) were measured during body position changes, designed to induce central blood volume shifts in ten cardiac and one heart-lung transplant recipients, to assess the contribution of cardiac volume receptors in the control of ADH release during the initial acute phase of exposure to weightlessness. Each subject underwent 15 min of a sitting-control period (C) followed by 30 min of 6 deg headdown tilt (T) and 30 min of resumed sitting (S). Venous blood samples and cardiac dimensions were taken at 0 and 15 min of C; 5, 15, and 30 min of T; and 5, 15, and 30 min of S. Blood samples were analyzed for hematocrit, plasma osmolality, plasma renin activity (PRA), and ADH. Heart rate and blood pressure were recorded every two min. Plasma osmolality was not altered by posture changes. Mean left ventricular end-diastolic volume increased (P less than 0.05) from 90 ml in C to 106 ml in T and returned to 87 ml in S. Plasma ADH was reduced by 20 percent (P less than 0.05) with T, and returned to control levels with S. These responses were similar in six normal cardiac-innervated control subjects. These data may suggest that cardiac volume receptors are not the primary mechanism for the control of ADH release during acute central volume shifts in man.
Sohbatzadeh, F; Eshghabadi, M; Mohsenpour, T
2018-06-29
The surface modification of cotton samples was carried out using a liquid (ethanol) electrospray-assisted atmospheric pressure plasma jet. X-ray photoelectron spectroscopy (XPS) and Raman analysis confirmed the successful deposition of diamond like carbon (DLC) nano structures on the cotton surface. The super hydrophobic state of the samples was probed by contact angle measurements. The water repellency of the layers was tuned by controlling the voltage applied to the electrospray electrode. An investigation of the morphological and chemical structures of the samples by field emission scanning microscopy, atomic force microscopy (AFM) and XPS indicated that the physical shape, distribution and amorphization of the DLC structures were successfully adjusted and improved by applying a voltage to the electrospray electrode. Finally wash durability of the best sample was tested for 35 cycles. In this work, the use of a well-developed atmospheric pressure plasma jet for DLC nano structures deposition can enable a promising environmentally friendly and low-cost approach for modifying cotton fabrics for super water-repellent fabric applications.
NASA Astrophysics Data System (ADS)
Sohbatzadeh, F.; Eshghabadi, M.; Mohsenpour, T.
2018-06-01
The surface modification of cotton samples was carried out using a liquid (ethanol) electrospray-assisted atmospheric pressure plasma jet. X-ray photoelectron spectroscopy (XPS) and Raman analysis confirmed the successful deposition of diamond like carbon (DLC) nano structures on the cotton surface. The super hydrophobic state of the samples was probed by contact angle measurements. The water repellency of the layers was tuned by controlling the voltage applied to the electrospray electrode. An investigation of the morphological and chemical structures of the samples by field emission scanning microscopy, atomic force microscopy (AFM) and XPS indicated that the physical shape, distribution and amorphization of the DLC structures were successfully adjusted and improved by applying a voltage to the electrospray electrode. Finally wash durability of the best sample was tested for 35 cycles. In this work, the use of a well-developed atmospheric pressure plasma jet for DLC nano structures deposition can enable a promising environmentally friendly and low-cost approach for modifying cotton fabrics for super water-repellent fabric applications.
Extraction of Thermal Performance Values from Samples in the Lunar Dust Adhesion Bell Jar
NASA Technical Reports Server (NTRS)
Gaier, James R.; Siamidis, John; Larkin, Elizabeth M. G.
2008-01-01
A simulation chamber has been developed to test the performance of thermal control surfaces under dusty lunar conditions. The lunar dust adhesion bell jar (LDAB) is a diffusion pumped vacuum chamber (10(exp -8) Torr) built to test material samples less than about 7 cm in diameter. The LDAB has the following lunar dust simulant processing capabilities: heating and cooling while stirring in order to degas and remove adsorbed water; RF air-plasma for activating the dust and for organic contaminant removal; RF H/He-plasma to simulate solar wind; dust sieving system for controlling particle sizes; and a controlled means of introducing the activated dust to the samples under study. The LDAB is also fitted with an in situ Xe arc lamp solar simulator, and a cold box that can reach 30 K. Samples of thermal control surfaces (2.5 cm diameter) are introduced into the chamber for calorimetric evaluation using thermocouple instrumentation. The object of this paper is to present a thermal model of the samples under test conditions and to outline the procedure to extract the absorptance, emittance, and thermal efficiency from the pristine and sub-monolayer dust covered samples.
Extraction of Thermal Performance Values from Samples in the Lunar Dust Adhesion Bell Jar
NASA Technical Reports Server (NTRS)
Gaier, James R.; Siamidis, John; Larkin, Elizabeth M.G.
2008-01-01
A simulation chamber has been developed to test the performance of thermal control surfaces under dusty lunar conditions. The lunar dust adhesion bell jar (LDAB) is a diffusion pumped vacuum chamber (10-8 Torr) built to test material samples less than about 7 cm in diameter. The LDAB has the following lunar dust stimulant processing capabilities: heating and cooling while stirring in order to degas and remove absorbed water; RF air-plasma for activating the dust and for organic contaminant removal; RF H/He-plasma to simulate solar wind; dust sieving system for controlling particle sizes; and a controlled means of introducing the activated dust to the samples under study. The LDAB is also fitted with an in situ Xe arc lamp solar simulator, and a cold box that can reach 30 K. Samples of thermal control surfaces (2.5 cm diameter) are introduced into the chamber for calorimetric evaluation using thermocouple instrumentation. The object of this paper is to present a thermal model of the samples under test conditions, and to outline the procedure to extract the absorptance, emittance, and thermal efficiency from the pristine and sub-monolayer dust covered samples
Extraction of Thermal Performance Values from Samples in the Lunar Dust Adhesion Bell Jar
NASA Technical Reports Server (NTRS)
Gaier, James R.; Siamidis, John; Larkin, Elizabeth M. G.
2010-01-01
A simulation chamber has been developed to test the performance of thermal control surfaces under dusty lunar conditions. The lunar dust adhesion bell jar (LDAB) is a diffusion pumped vacuum chamber (10(exp -8) Torr) built to test material samples less than about 7 cm in diameter. The LDAB has the following lunar dust simulant processing capabilities: heating and cooling while stirring in order to degas and remove adsorbed water; RF air-plasma for activating the dust and for organic contaminant removal; RF H/He-plasma to simulate solar wind; dust sieving system for controlling particle sizes; and a controlled means of introducing the activated dust to the samples under study. The LDAB is also fitted with an in situ Xe arc lamp solar simulator, and a cold box that can reach 30 K. Samples of thermal control surfaces (2.5 cm diameter) are introduced into the chamber for calorimetric evaluation using thermocouple instrumentation. The object of this paper is to present a thermal model of the samples under test conditions and to outline the procedure to extract the absorptance, emittance, and thermal efficiency from the pristine and sub-monolayer dust covered samples.
Measurement of plasma cell-free DNA concentrations in dogs with sepsis, trauma, and neoplasia.
Letendre, Jo-Annie; Goggs, Robert
2017-05-01
To determine if cell-free DNA (cfDNA) was identifiable in canine plasma, to evaluate 3 techniques for the measurement of plasma cfDNA concentrations in dogs presented to an emergency service, and to compare the plasma cfDNA concentrations of healthy dogs to those with sepsis, trauma, and neoplasia. Retrospective study of banked canine plasma samples collected between May 2014 and December 2014. Dogs presented to the emergency service of a university veterinary teaching hospital. Plasma cfDNA was measured on residual plasma samples obtained from 15 dogs with sepsis, 15 dogs with moderate-severe trauma, 15 dogs diagnosed with a sarcoma. Plasma cfDNA was also measured in 15 healthy dogs. None. Assay linearity, repeatability, and reproducibility were evaluated. Quantification of cfDNA was performed in duplicate on diluted citrated plasma and following DNA purification using 2 fluorescence assays (SYBR-Gold; Quant-iT) and by ultraviolet absorbance spectroscopy. Fluorescence intensities (FIs) were converted to cfDNA concentrations using standard curves. Median FI values and cfDNA concentrations were compared to healthy controls using the Kruskal-Wallis test, with adjustment for multiple comparisons. Alpha was set at 0.05. Both assays had excellent linearity, and acceptable repeatability and reproducibility. Compared to controls, plasma cfDNA concentrations were significantly increased in dogs with sepsis or moderate-severe trauma with both assays (P ≤ 0.003). Dogs with neoplasia had significantly increased cfDNA concentrations with the Quant-iT assay only (P = 0.003). When measurements were performed on purified DNA, only dogs with moderate-severe trauma had significantly increased cfDNA concentrations (P < 0.001; SYBR-Gold assay). cfDNA can be readily identified in canine plasma using 2 fluorescence assays. DNA extraction offers no advantage over direct measurement. Compared to healthy controls, dogs with sepsis or moderate-severe trauma have significantly increased plasma cfDNA concentrations. © Veterinary Emergency and Critical Care Society 2017.
Kemeny, Nancy; Kingham, T. Peter; Allen, Peter J.; D’Angelica, Michael I.; DeMatteo, Ronald P.; Betel, Doron; Klimstra, David; Jarnagin, William R.; Ventura, Andrea
2016-01-01
Background MicroRNAs (miRNAs) are potential biomarkers in various malignancies. We aim to characterize miRNA expression in intrahepatic cholangiocarcinoma (ICC) and identify circulating plasma miRNAs with potential diagnostic and prognostic utility. Methods Using deep-sequencing techniques, miRNA expression between tumor samples and non-neoplastic liver parenchyma were compared. Overexpressed miRNAs were measured in plasma from an independent cohort of patients with cholangiocarcinoma using RT-qPCR and compared with that healthy volunteers. The discriminatory ability of the evaluated plasma miRNAs between patients and controls was evaluated with receiving operating characteristic (ROC) curves. Results Small RNAs from 12 ICC and 11 tumor-free liver samples were evaluated. Unsupervised hierarchical clustering using the miRNA expression data showed clear grouping of ICC vs. non-neoplastic liver parenchyma. We identified 134 down-regulated and 128 upregulated miRNAs. Based on overexpression and high fold-change, miR21, miR200b, miR221, and miR34c were measured in plasma from an independent cohort of patients with ICC (n = 25) and healthy controls (n = 7). Significant overexpression of miR-21 and miR-221 was found in plasma from ICC patients. Furthermore, circulating miR-21 demonstrated a high discriminatory ability between patients with ICC and healthy controls (AUC: 0.94). Conclusion Among the differentially expressed miRNAs in ICC, miR-21 and miR-221 are overexpressed and detectable in the circulation. Plasma expression levels of these miRNAs, particularly miR-21, accurately differentiates patients with ICC from healthy controls and could potentially serve as adjuncts in diagnosis. Prospective validation and comparison with other hepatobiliary malignancies is required to establish their potential role as diagnostic and prognostic biomarkers. PMID:27685844
Schønning, Kristian; Johansen, Kim; Landt, Bodil; Benfield, Thomas; Westh, Henrik
2017-07-01
HIV-RNA is the most important parameter for monitoring antiviral treatment in individuals infected with HIV-1. Knowledge of the performance of different tests for the quantification of HIV-1 RNA is therefore important for clinical care. To compare the analytical performance of the Aptima HIV-1 Quant Dx Assay (Aptima) and the COBAS Ampliprep/COBAS TaqMan HIV-1 Test v2.0 (CAPCTMv2) for the quantification of HIV-1 RNA in plasma samples. The performance of the two tests was compared on 216 clinical plasma samples, on dilutions series in seven replicates of five clinical samples of known subtype and on ten replicates of the Acrometrix High and Low Positive Control. Bland-Altman analysis of 130 samples that quantified in both tests did not show indications of gross mis-quantification of either test. A tendency of the Aptima assay to quantify higher at high viral load compared to the CAPCTMv2 was observed in Bland-Altman analysis, by Deming regression (Slope 1.13) and in dilution series of clinical samples. Precision evaluated using the Acrometrix Positive Controls was similar for the High Control (CV: 1.2% vs. 1.3%; Aptima assay vs. CAPCTMv2 test, respectively), but differed for the Low control (CV: 17.9% vs. 7.1%; Aptima assay vs. CAPCTMv2 test, respectively). However, this did not impact clinical categorization of clinical samples at neither the 50 cp/mL nor 200 cp/mL level. The Aptima assay and the CAPCTMv2 test are highly correlated and are useful for monitoring HIV-infected individuals. Copyright © 2017 Elsevier B.V. All rights reserved.
The role of BDNF, leptin, and catecholamines in reward learning in bulimia nervosa.
Homan, Philipp; Grob, Simona; Milos, Gabriella; Schnyder, Ulrich; Eckert, Anne; Lang, Undine; Hasler, Gregor
2014-12-07
A relationship between bulimia nervosa and reward-related behavior is supported by several lines of evidence. The dopaminergic dysfunctions in the processing of reward-related stimuli have been shown to be modulated by the neurotrophin brain derived neurotrophic factor (BDNF) and the hormone leptin. Using a randomized, double-blind, placebo-controlled, crossover design, a reward learning task was applied to study the behavior of 20 female subjects with remitted bulimia nervosa and 27 female healthy controls under placebo and catecholamine depletion with alpha-methyl-para-tyrosine (AMPT). The plasma levels of BDNF and leptin were measured twice during the placebo and the AMPT condition, immediately before and 1 hour after a standardized breakfast. AMPT-induced differences in plasma BDNF levels were positively correlated with the AMPT-induced differences in reward learning in the whole sample (P=.05). Across conditions, plasma brain derived neurotrophic factor levels were higher in remitted bulimia nervosa subjects compared with controls (diagnosis effect; P=.001). Plasma BDNF and leptin levels were higher in the morning before compared with after a standardized breakfast across groups and conditions (time effect; P<.0001). The plasma leptin levels were higher under catecholamine depletion compared with placebo in the whole sample (treatment effect; P=.0004). This study reports on preliminary findings that suggest a catecholamine-dependent association of plasma BDNF and reward learning in subjects with remitted bulimia nervosa and controls. A role of leptin in reward learning is not supported by this study. However, leptin levels were sensitive to a depletion of catecholamine stores in both remitted bulimia nervosa and controls. © The Author 2015. Published by Oxford University Press on behalf of CINP.
Mitchell, Thomas A; Herzig, Maryanne C; Fedyk, Chriselda G; Salhanick, Marc A; Henderson, Aaron T; Parida, Bijaya K; Prat, Nicolas J; Dent, Daniel L; Schwacha, Martin G; Cap, Andrew P
2017-06-01
Autotransfusion of shed blood from traumatic hemothorax is an attractive option for resuscitation of trauma patients in austere environments. However, previous analyses revealed that shed hemothorax (HX) blood is defibrinated, thrombocytopenic, and contains elevated levels of D-dimer. Mixing studies with normal pooled plasma demonstrated hypercoagulability, evoking concern for potentiation of acute traumatic coagulopathy. We hypothesized that induction of coagulopathic changes by shed HX blood may be due to increases in cellular microparticles (MP) and that these may also affect recipient platelet function. Shed HX blood was obtained from 17 adult trauma patients under an Institutional Review Board approved prospective observational protocol. Blood samples were collected every hour up to 4 h after thoracostomy tube placement. The corresponding plasma was isolated and frozen for analysis. The effects of shed HX frozen plasma (HFP) and isolated HX microparticles (HMP) on coagulation and platelet function were assessed through mixing studies with platelet-rich plasma at various dilutions followed by analysis with thromboelastometry (ROTEM), platelet aggregometry (Multiplate), enzyme-linked immunosorbent assays, and flow cytometry. Furthermore, HFP was assessed for von Willebrand factor antigen levels and multimer content, and plasma-free hemoglobin. ROTEM analysis demonstrated that diluted HFP and isolated HMP samples decreased clotting time, clotting formation time, and increased α angle, irrespective of sample concentrations, when compared with diluted control plasma. Isolated HMP inhibited platelet aggregation in response to adenosine diphosphate, arachidonic acid, and collagen. HFP contained elevated levels of fibrin-degradation products and tissue factor compared with control fresh frozen plasma samples. MP concentrations in HFP were significantly increased and enriched in events positive for phosphatidylserine, tissue factor, CD235, CD45, CD41a, and CD14. von Willebrand factor (vWF) multimer analysis revealed significant loss of high molecular weight multimers in HFP samples. Plasma-free hemoglobin levels were 8-fold higher in HFP compared with fresh frozen plasma. HFP induces plasma hypercoagulability that is likely related to increased tissue factor and phosphatidylserine expression originating from cell-derived MP. In contrast, platelet dysfunction is induced by HMP, potentially aggravated by depletion of high molecular weight multimers of vWF. Thus, autologous transfusion of shed traumatic hemothorax blood may induce a range of undesirable effects in patients with acute traumatic coagulopathy.
Development of alternative plasma sources for cavity ring-down measurements of mercury.
Duan, Yixiang; Wang, Chuji; Scherrer, Susan T; Winstead, Christopher B
2005-08-01
We have been exploring innovative technologies for elemental and hyperfine structure measurements using cavity ring-down spectroscopy (CRDS) combined with various plasma sources. A laboratory CRDS system utilizing a tunable dye laser is employed in this work to demonstrate the feasibility of the technology. An in-house fabricated sampling system is used to generate aerosols from solution samples and introduce the aerosols into the plasma source. The ring-down signals are monitored using a photomultiplier tube and recorded using a digital oscilloscope interfaced to a computer. Several microwave plasma discharge devices are tested for mercury CRDS measurement. Various discharge tubes have been designed and tested to reduce background interference and increase the sample path length while still controlling turbulence generated from the plasma gas flow. Significant background reduction has been achieved with the implementation of the newly designed tube-shaped plasma devices, which has resulted in a detection limit of 0.4 ng/mL for mercury with the plasma source CRDS. The calibration curves obtained in this work readily show that linearity over 2 orders of magnitude can be obtained with plasma-CRDS for mercury detection. In this work, the hyperfine structure of mercury at the experimental plasma temperatures is clearly identified. We expect that plasma source cavity ring-down spectroscopy will provide enhanced capabilities for elemental and isotopic measurements.
Tintos, Adrián; Gesto, Manuel; Alvarez, Rosa; Míguez, Jesús M; Soengas, José L
2006-10-01
The purpose of the study was to assess in female fish the possible interaction between treatment with a polycyclic aromatic hydrocarbon (PAH) like naphthalene and the onset of vitellogenesis. In a first experiment, female rainbow trout (Oncorhynchus mykiss) at stages 2-3 (previtellogenesis) or 4 (early vitellogenesis) were intraperitoneally injected (2 microl g(-1)) with vegetable oil alone (control) or containing naphthalene (50 mg kg(-1)) to be sampled 3 h later. A second experiment was similarly designed but using fish intraperitoneally implanted (10 microl g(-1)) with slow-release coconut oil implants alone (control) or containing 50 mg naphthalene kg(-1) body mass that were sampled 3 days after injection. On each sampling time, plasma levels of cortisol and 17beta-estradiol, and several metabolic parameters in plasma, liver and gonad were assessed. In controls, early vitellogenic fish compared with previtellogenic fish displayed changes that in some cases are confirmatory of previous studies whereas in other cases provide new information in plasma (increased amino acid levels), liver (decreased capacity for exporting glucose and reduced amino acid levels) and gonad (decreased amino acid levels). Naphthalene treatment produced in previtellogenic fish decreased 17beta-estradiol levels in plasma, increased plasma glucose or decreased liver gluconeogenic capacity whereas no major effects were noticed on parameters involved in lipid, amino acid and lactate metabolism. Differential effects of naphthalene treatment were noticed in early vitellogenic fish such as decreased 17beta-estradiol and glucose levels in plasma, increased hexokinase and glucokinase and lack of changes in fructose 1,6-bisphosphatase activities in liver, and a lower decrease of amino acid levels in gonad. Those alterations produced by naphthalene treatment resulted in a decreased capacity for covering the energy demand of vitellogenesis in liver and gonad that could contribute to a delay and/or impairment of the onset of maturation.
Fletcher, Daniel J; Rozanski, Elizabeth A; Brainard, Benjamin M; de Laforcade, Armelle M; Brooks, Marjory B
2016-01-01
To relate coagulation and fibrinolysis derangements to shock severity as reflected by plasma lactate concentrations in dogs with spontaneous hemoperitoneum (SHP) and determine the impact on transfusions. Prospective, observational, case-control study. Three veterinary teaching hospitals. Twenty-eight client-owned dogs with SHP and 28 breed- and age-matched control dogs. None. Blood samples for platelet counts, coagulation, and anticoagulant assays (prothrombin time, activated partial thromboplastin time, fibrinogen, antithrombin, and protein C, thromboelastography [TEG]), fibrinolysis testing (d-dimer and TEG lysis parameters with and without the addition of 50 U/mL of tissue plasminogen activator [TEG LY30 measured with the addition of 50 U/mL of tPA to the blood sample, LY3050 and TEG LY60 measured with the addition of 50 U/mL of tPA to the blood sample, LY6050 ; LY30 and LY60]), and plasma lactate as an indicator of severity of shock were collected from SHP dogs at the time of diagnosis. SHP dogs were hypocoagulable (prolonged prothrombin time and activated partial thromboplastin time, decreased TEG maximum amplitude) and hyperfibrinolytic (increased LY3050 and TEG LY6050 ) compared to controls. The severity of hypocoagulability was related to protein C activity, while the severity of hyperfibrinolysis was related to plasma lactate concentration. Among the 18 dogs discharged from the hospital, LY3050 was significantly associated with the dose of fresh frozen plasma administered, but none of the parameters were associated with the dose of red blood cells administered. Dogs with SHP have evidence of hypocoagulability, protein C deficiency, and hyperfibrinolysis. Parameters of hyperfibrinolysis were related to plasma lactate concentrations and volume of plasma transfused during hospitalization. These derangements resemble those found in people with acute coagulopathy of trauma and shock, and activation of protein C may be a common feature to both syndromes. © Veterinary Emergency and Critical Care Society 2015.
A plasma microRNA signature as a biomarker for acquired aplastic anemia.
Hosokawa, Kohei; Kajigaya, Sachiko; Feng, Xingmin; Desierto, Marie J; Fernandez Ibanez, Maria Del Pilar; Rios, Olga; Weinstein, Barbara; Scheinberg, Phillip; Townsley, Danielle M; Young, Neal S
2017-01-01
Aplastic anemia is an acquired bone marrow failure characterized by marrow hypoplasia, a paucity of hematopoietic stem and progenitor cells, and pancytopenia of the peripheral blood, due to immune attack on the bone marrow. In aplastic anemia, a major challenge is to develop immune biomarkers to monitor the disease. We measured circulating microRNAs in plasma samples of aplastic anemia patients in order to identify disease-specific microRNAs. A total of 179 microRNAs were analyzed in 35 plasma samples from 13 aplastic anemia patients, 11 myelodysplastic syndrome patients, and 11 healthy controls using the Serum/Plasma Focus microRNA Polymerase Chain Reaction Panel. Subsequently, 19 microRNAs from the discovery set were investigated in the 108 plasma samples from 41 aplastic anemia patients, 24 myelodysplastic syndrome patients, and 43 healthy controls for validation, confirming that 3 microRNAs could be validated as dysregulated (>1.5-fold change) in aplastic anemia, compared to healthy controls. MiR-150-5p (induction of T-cell differentiation) and miR-146b-5p (involvement in the feedback regulation of innate immune response) were elevated in aplastic anemia plasma, whereas miR-1 was decreased in aplastic anemia. By receiver operating characteristic curve analysis, we developed a logistic model with these 3 microRNAs that enabled us to predict the probability of a diagnosis of aplastic anemia with an area under the curve of 0.86. Dysregulated expression levels of the microRNAs became normal after immunosuppressive therapy at 6 months. Specifically, miR-150-5p expression was significantly reduced after successful immunosuppressive therapy, but did not change in non-responders. We propose 3 novel plasma biomarkers in aplastic anemia, in which miR-150-5p, miR-146b-5p, and miR-1 can serve for diagnosis and miR-150-5p for disease monitoring. Clinicaltrials.gov identifiers:00260689, 00217594, 00961064. Copyright© Ferrata Storti Foundation.
NASA Technical Reports Server (NTRS)
Carden, J. L.; Browner, R.
1982-01-01
The preparation and analysis of standardized waste samples for controlled ecological life support systems (CELSS) are considered. Analysis of samples from wet oxidation experiments, the development of ion chromatographic techniques utilizing conventional high pressure liquid chromatography (HPLC) equipment, and an investigation of techniques for interfacing an ion chromatograph (IC) with an inductively coupled plasma optical emission spectrometer (ICPOES) are discussed.
Carobene, Anna; Strollo, Marta; Jonker, Niels; Barla, Gerhard; Bartlett, William A; Sandberg, Sverre; Sylte, Marit Sverresdotter; Røraas, Thomas; Sølvik, Una Ørvim; Fernandez-Calle, Pilar; Díaz-Garzón, Jorge; Tosato, Francesca; Plebani, Mario; Coşkun, Abdurrahman; Serteser, Mustafa; Unsal, Ibrahim; Ceriotti, Ferruccio
2016-10-01
Biological variation (BV) data have many fundamental applications in laboratory medicine. At the 1st Strategic Conference of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) the reliability and limitations of current BV data were discussed. The EFLM Working Group on Biological Variation is working to increase the quality of BV data by developing a European project to establish a biobank of samples from healthy subjects to be used to produce high quality BV data. The project involved six European laboratories (Milan, Italy; Bergen, Norway; Madrid, Spain; Padua, Italy; Istanbul, Turkey; Assen, The Netherlands). Blood samples were collected from 97 volunteers (44 men, aged 20-60 years; 43 women, aged 20-50 years; 10 women, aged 55-69 years). Initial subject inclusion required that participants completed an enrolment questionnaire to verify their health status. The volunteers provided blood specimens once per week for 10 weeks. A short questionnaire was completed and some laboratory tests were performed at each sampling consisting of blood collected under controlled conditions to provide serum, K2EDTA-plasma and citrated-plasma samples. Samples from six out of the 97 enroled subjects were discarded as a consequence of abnormal laboratory measurements. A biobank of 18,000 aliquots was established consisting of 120 aliquots of serum, 40 of EDTA-plasma, and 40 of citrated-plasma from each subject. The samples were stored at -80 °C. A biobank of well-characterised samples collected under controlled conditions has been established delivering a European resource to enable production of contemporary BV data.
Kook, Min-Suk; Roh, Hee-Sang; Kim, Byung-Hoon
2018-05-02
This study was to investigate the effects of O 2 plasma-etching of the 3D polycaprolactone (PCL) scaffold surface on preosteoblast cell proliferation and differentiation, and early new bone formation. The PCL scaffolds were fabricated by 3D printing technique. After O 2 plasma treatment, surface characterizations were examined by scanning electron microscopy, atomic force microscopy, and contact angle. MTT assay was used to determine cell proliferation. To investigate the early new bone formation, rabbits were sacrificed at 2 weeks for histological analyses. As the O 2 plasma etching time is increased, roughness and hydrophilicity of the PCL scaffold surface increased. The cell proliferation and differentiation on plasma-etched samples was significantly increased than on untreated samples. At 2 weeks, early new bone formation in O 2 plasma-etched PCL scaffolds was the higher than that of untreated scaffolds. The O 2 plasma-etched PCL scaffolds showed increased preosteoblast differentiation as well as increased new bone formation.
Surface modification of gutta-percha cones by non-thermal plasma.
Prado, Maíra; Menezes, Marilia Santana de Oliveira; Gomes, Brenda Paula Figueiredo de Almeida; Barbosa, Carlos Augusto de Melo; Athias, Leonardo; Simão, Renata Antoun
2016-11-01
This study was designed to evaluate the effects of Oxygen and Argon plasma on gutta-percha surfaces. A total of 185 flat smooth gutta-percha surfaces were used. Samples were divided into groups: control: no plasma treatment; Oxygen: treatment with Oxygen plasma for 1min; Argon: treatment with Argon plasma for 1min. Samples were evaluated topographically by scanning electron microscopy and atomic force microscopy; and chemically by Fourier Transform-infrared Spectroscopy. A goniometer was used to determine the surface free energy and the wettability of the endodontic sealers. Additionally 60 bovine teeth were filled using pellets of gutta-percha (control, oxygen and argon plasma) and the sealers. Teeth were evaluated by push-out and microleakage tests. Data were statistically analyzed using specific tests. Argon plasma did not change the surface topography, while Oxygen plasma led to changes. Both treatments chemically modified the gutta-percha surface. Argon and Oxygen plasma increased the surface free energy and favored the wettability of AH Plus and Pulp Canal Sealer EWT. Regarding bond strength analysis, for AH Plus sealer, both plasma treatments on gutta-percha favored the bond strength to dentin. However, for Pulp Canal Sealer, there is no statistically significant influence. For leakage test, dye penetration occurred between sealer and dentin in all groups. In conclusion, Oxygen plasma led to both topographic and chemical changes in the gutta-percha surface, while Argon plasma caused only chemical changes. Both treatments increased the surface free energy, favoring the wettability of AH Plus and Pulp Canal Sealer EWT sealers and influenced positively in the adhesion and leakage. Copyright © 2016 Elsevier B.V. All rights reserved.
Osteopontin is a tumor autoantigen in prostate cancer patients
TILLI, TATIANA M.; SILVA, ELOÍSIO A.; MATOS, LÍVIA C.; FAGET, DOUGLAS V.; DIAS, BIANCA F.P.; VASCONCELOS, JULIANA S.P.; YOKOSAKI, YASUYUKI; GIMBA, ETEL R.P.
2011-01-01
Anti-tumor antibodies act as biomarkers for the early diagnosis of prostate cancer (PCa). Osteopontin (OPN) is overexpressed in PCa cells and contributes to the progression of the disease. This study aimed to evaluate whether OPN evokes a humoral immune response in PCa patients and whether the reactivity levels of anti-OPN antibodies may be used to better differentiate PCa from benign and healthy donor plasma samples. Plasma samples from biopsy-proven PCa patients (29), benign prostate hyperplasia (BPH) (18) and control healthy donors (HD) (30) were tested by immunoblots using the recombinant human OPN. The frequency of anti-OPN antibodies was significantly higher in PCa (66%) plasma samples as compared to BPH (33%) and HD controls (10%). Anti-OPN antibodies were detected in a high proportion of plasma samples from patients with a Gleason score of less than 6 (57%), prostate-specific antigen levels lower than 10 ng/ml (67%) and pT2 organ-confined disease (70%), suggesting that anti-OPN antibodies may be used as an early serum marker for PCa. To the best of our knowledge, this is the first description of OPN as a tumor autoantigen and one of the most reactive individual autoantigens described thus far. These data support the inclusion of OPN in a multiplex of tumor antigens in order to perform antibody profiling in PCa as well as in other malignancies overexpressing OPN. PMID:22870138
Klotho dysfunction: A pathway linking the aging process to bipolar disorder?
Barbosa, Izabela Guimarães; Rocha, Natalia Pessoa; Alpak, Gokay; Vieira, Erica Leandro Marciano; Huguet, Rodrigo Barreto; Rocha, Fabio Lopes; de Oliveira Diniz, Breno Satler; Teixeira, Antonio Lucio
2017-12-01
Although accelerated aging profile has been described in bipolar disorder (BD), the biology linking BD and aging is still largely unknown. Reduced levels and/or activity of a protein named Klotho is associated with decreased life span, premature aging and occurrence of age-related diseases. Therefore, this study was designed to evaluate plasma levels of Klotho in BD patients and controls. Forty patients with type 1 BD and 30 controls were enrolled in this study. After clinical evaluation, peripheral blood samples were drawn and plasma levels of Klotho were measured using enzyme-linked immunosorbent assay. Patients with BD and controls presented similar age and sex distribution. The mean ± SD length of illness was 24.00 ± 12.75 years. BD patients presented increased frequency of clinical comorbidities in comparison with controls, mainly arterial hypertension, diabetes mellitus, and hypothyroidism. Both patients with BD in remission and in mania exhibited increased plasma levels of Klotho in comparison with controls. There was no significant difference between patients in mania and patients in remission regarding the levels of Klotho. Klotho-related pathway is altered in BD. Contrary to our original hypothesis, our sample of patients with BD presented increased plasma levels of Klotho in comparison with controls. Elevated levels of Klotho in long-term BD patients may be associated with the disorder progression. Further studies are needed to better understand the role of Klotho in BD and other mood disorders. Copyright © 2017 Elsevier Ltd. All rights reserved.
Ogawa, Tadashi; Hattori, Hideki; Kaneko, Rina; Ito, Kenjiro; Iwai, Masayo; Mizutani, Yoko; Arinobu, Tetsuya; Ishii, Akira; Suzuki, Osamu; Seno, Hiroshi
2010-01-01
A rapid and sensitive method for analysis of blonanserin in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry is presented. After pretreatment of a plasma sample by solid-phase extraction, blonanserin was analyzed by the system with a C(18) column. This method gave satisfactory recovery rates, reproducibility, and good linearity of calibration curve in the range of 0.01-10.0 ng/mL for quality control samples spiked with blonanserin. The detection limit was as low as 1 pg/mL. This method seems very useful in forensic and clinical toxicology and pharmacokinetic studies.
Digital Plasma Control System for Alcator C-Mod
NASA Astrophysics Data System (ADS)
Ferrara, M.; Wolfe, S.; Stillerman, J.; Fredian, T.; Hutchinson, I.
2004-11-01
A digital plasma control system (DPCS) has been designed to replace the present C-Mod system, which is based on hybrid analog-digital computer. The initial implementation of DPCS comprises two 64 channel, 16 bit, low-latency cPCI digitizers, each with 16 analog outputs, controlled by a rack-mounted single-processor Linux server, which also serves as the compute engine. A prototype system employing three older 32 channel digitizers was tested during the 2003-04 campaign. The hybrid's linear PID feedback system was emulated by IDL code executing a synchronous loop, using the same target waveforms and control parameters. Reliable real-time operation was accomplished under a standard Linux OS (RH9) by locking memory and disabling interrupts during the plasma pulse. The DPCS-computed outputs agreed to within a few percent with those produced by the hybrid system, except for discrepancies due to offsets and non-ideal behavior of the hybrid circuitry. The system operated reliably, with no sample loss, at more than twice the 10kHz design specification, providing extra time for implementing more advanced control algorithms. The code is fault-tolerant and produces consistent output waveforms even with 10% sample loss.
Pre-treatment plasma proteomic markers associated with survival in oesophageal cancer
Kelly, P; Paulin, F; Lamont, D; Baker, L; Clearly, S; Exon, D; Thompson, A
2012-01-01
Background: The incidence of oesophageal adenocarcinoma is increasing worldwide but survival remains poor. Neoadjuvant chemotherapy can improve survival, but prognostic and predictive biomarkers are required. This study built upon preclinical approaches to identify prognostic plasma proteomic markers in oesophageal cancer. Methods: Plasma samples collected before and during the treatment of oesophageal cancer and non-cancer controls were analysed by surface-enhanced laser desorption/ionisation time-of-flight (SELDI-TOF) mass spectroscopy (MS). Protein peaks were identified by MS in tryptic digests of purified fractions. Associations between peak intensities obtained in the spectra and clinical endpoints (survival, disease-free survival) were tested by univariate (Fisher's exact test) and multivariate analysis (binary logistic regression). Results: Plasma protein peaks were identified that differed significantly (P<0.05, ANOVA) between the oesophageal cancer and control groups at baseline. Three peaks, confirmed as apolipoprotein A-I, serum amyloid A and transthyretin, in baseline (pre-treatment) samples were associated by univariate and multivariate analysis with disease-free survival and overall survival. Conclusion: Plasma proteins can be detected prior to treatment for oesophageal cancer that are associated with outcome and merit testing as prognostic and predictive markers of response to guide chemotherapy in oesophageal cancer. PMID:22294182
Pre-treatment plasma proteomic markers associated with survival in oesophageal cancer.
Kelly, P; Paulin, F; Lamont, D; Baker, L; Clearly, S; Exon, D; Thompson, A
2012-02-28
The incidence of oesophageal adenocarcinoma is increasing worldwide but survival remains poor. Neoadjuvant chemotherapy can improve survival, but prognostic and predictive biomarkers are required. This study built upon preclinical approaches to identify prognostic plasma proteomic markers in oesophageal cancer. Plasma samples collected before and during the treatment of oesophageal cancer and non-cancer controls were analysed by surface-enhanced laser desorption/ionisation time-of-flight (SELDI-TOF) mass spectroscopy (MS). Protein peaks were identified by MS in tryptic digests of purified fractions. Associations between peak intensities obtained in the spectra and clinical endpoints (survival, disease-free survival) were tested by univariate (Fisher's exact test) and multivariate analysis (binary logistic regression). Plasma protein peaks were identified that differed significantly (P<0.05, ANOVA) between the oesophageal cancer and control groups at baseline. Three peaks, confirmed as apolipoprotein A-I, serum amyloid A and transthyretin, in baseline (pre-treatment) samples were associated by univariate and multivariate analysis with disease-free survival and overall survival. Plasma proteins can be detected prior to treatment for oesophageal cancer that are associated with outcome and merit testing as prognostic and predictive markers of response to guide chemotherapy in oesophageal cancer.
Shen, Yang; Wang, Guixue; Chen, Liang; Li, Hao; Yu, Ping; Bai, Mengjun; Zhang, Qin; Lee, James; Yu, Qingsong
2009-11-01
Plasma nanocoated films with trimethylsilane-oxygen monomers showed outstanding biocompatibility in our previous studies. In this study, endothelialization on biomedical nitinol alloy surfaces was systematically investigated. Our study focuses on elucidating the effects of surface micropatternings with micropores and microgrooves combined with plasma nanocoating. Plasma nanocoatings with controlled thickness between 40 and 50 nm were deposited onto micropatterned nitinol surface in a direct current plasma reactor. Bovine aortic endothelial cells were cultured in vitro on these nitinol samples for 1, 3 and 5 days. It was found that rougher surfaces could enhance cell adhesion compared with the smoother surfaces; the surfaces patterned with micropores showed much more endothelialization than microgrooved surface after a 3 days culture. The cell culture results also showed that plasma nanocoatings significantly further increased cell proliferation and cell adhesion on the micropatterned nitinol surfaces, as compared with non-plasma nanocoated surface of nitinol samples. The surface micropatternings combined with plasma nanocoatings could improve the cell adhesion and accelerate surface endothelialization after implantation of intravascular stents, which is expected to reduce in-stent restenosis.
Identification of a Hemolysis Threshold That Increases Plasma and Serum Zinc Concentration.
Killilea, David W; Rohner, Fabian; Ghosh, Shibani; Otoo, Gloria E; Smith, Lauren; Siekmann, Jonathan H; King, Janet C
2017-06-01
Background: Plasma or serum zinc concentration (PZC or SZC) is the primary measure of zinc status, but accurate sampling requires controlling for hemolysis to prevent leakage of zinc from erythrocytes. It is not established how much hemolysis can occur without changing PZC/SZC concentrations. Objective: This study determines a guideline for the level of hemolysis that can significantly elevate PZC/SZC. Methods: The effect of hemolysis on PZC/SZC was estimated by using standard hematologic variables and mineral content. The calculated hemolysis threshold was then compared with results from an in vitro study and a population survey. Hemolysis was assessed by hemoglobin and iron concentrations, direct spectrophotometry, and visual assessment of the plasma or serum. Zinc and iron concentrations were determined by inductively coupled plasma spectrometry. Results: A 5% increase in PZC/SZC was calculated to result from the lysis of 1.15% of the erythrocytes in whole blood, corresponding to ∼1 g hemoglobin/L added into the plasma or serum. Similarly, the addition of simulated hemolysate to control plasma in vitro caused a 5% increase in PZC when hemoglobin concentrations reached 1.18 ± 0.10 g/L. In addition, serum samples from a population nutritional survey were scored for hemolysis and analyzed for changes in SZC; samples with hemolysis in the range of 1-2.5 g hemoglobin/L showed an estimated increase in SZC of 6% compared with nonhemolyzed samples. Each approach indicated that a 5% increase in PZC/SZC occurs at ∼1 g hemoglobin/L in plasma or serum. This concentration of hemoglobin can be readily identified directly by chemical hemoglobin assays or indirectly by direct spectrophotometry or matching to a color scale. Conclusions: A threshold of 1 g hemoglobin/L is recommended for PZC/SZC measurements to avoid increases in zinc caused by hemolysis. The use of this threshold may improve zinc assessment for monitoring zinc status and nutritional interventions.
Identification of a Hemolysis Threshold That Increases Plasma and Serum Zinc Concentration123
Otoo, Gloria E; Smith, Lauren; Siekmann, Jonathan H
2017-01-01
Background: Plasma or serum zinc concentration (PZC or SZC) is the primary measure of zinc status, but accurate sampling requires controlling for hemolysis to prevent leakage of zinc from erythrocytes. It is not established how much hemolysis can occur without changing PZC/SZC concentrations. Objective: This study determines a guideline for the level of hemolysis that can significantly elevate PZC/SZC. Methods: The effect of hemolysis on PZC/SZC was estimated by using standard hematologic variables and mineral content. The calculated hemolysis threshold was then compared with results from an in vitro study and a population survey. Hemolysis was assessed by hemoglobin and iron concentrations, direct spectrophotometry, and visual assessment of the plasma or serum. Zinc and iron concentrations were determined by inductively coupled plasma spectrometry. Results: A 5% increase in PZC/SZC was calculated to result from the lysis of 1.15% of the erythrocytes in whole blood, corresponding to ∼1 g hemoglobin/L added into the plasma or serum. Similarly, the addition of simulated hemolysate to control plasma in vitro caused a 5% increase in PZC when hemoglobin concentrations reached 1.18 ± 0.10 g/L. In addition, serum samples from a population nutritional survey were scored for hemolysis and analyzed for changes in SZC; samples with hemolysis in the range of 1–2.5 g hemoglobin/L showed an estimated increase in SZC of 6% compared with nonhemolyzed samples. Each approach indicated that a 5% increase in PZC/SZC occurs at ∼1 g hemoglobin/L in plasma or serum. This concentration of hemoglobin can be readily identified directly by chemical hemoglobin assays or indirectly by direct spectrophotometry or matching to a color scale. Conclusions: A threshold of 1 g hemoglobin/L is recommended for PZC/SZC measurements to avoid increases in zinc caused by hemolysis. The use of this threshold may improve zinc assessment for monitoring zinc status and nutritional interventions. PMID:28490675
Circular RNA hsa_circ_0000745 may serve as a diagnostic marker for gastric cancer.
Huang, Mei; He, Yi-Ren; Liang, Li-Chuan; Huang, Qiang; Zhu, Zhi-Qiang
2017-09-14
To determine whether circular RNAs (circRNAs) are involved in pathological processes of gastric cancer (GC). Three circRNAs with differential expression in GC and colorectal cancer were randomly selected for validation by quantitative reverse transcription-polymerase chain reaction (qRT-PCR), using 20 pairs of gastric tissues and normal tissues. Based on the predicted circRNA-miRNA network, we then focused on hsa_circ_0000745, which was found to be down-regulated in 20 GC tissues compared with normal tissues. The hsa_circ_0000745 levels were further analyzed by qRT-PCR in 60 GC tissues and paired adjacent non-tumor tissues, as well as 60 plasma samples from GC patients and 60 plasma samples from healthy controls. The associations between the levels of hsa_circ_0000745 and the clinicopathological features of GC patients were statistically assessed. A receiver operating characteristic (ROC) curve was used to evaluate the diagnostic value of hsa_circ_0000745 in GC. Hsa_circ_0000745 was down-regulated in GC tissues vs non-tumorous tissues ( P < 0.001) and in plasma samples from patients with GC vs healthy controls ( P < 0.001). The expression level of hsa_circ_0000745 in GC tissues correlated with tumor differentiation, while the expression level in plasma correlated with tumor-node-metastasis stage. The area under the ROC curve (AUC) of hsa_circ_0000745 in plasma was 0.683, suggesting good diagnostic value. Plasma hsa_circ_0000745 level combined with carcinoembryogenic antigen (CEA) level increased the AUC to 0.775. Hsa_circ_0000745 plays an important role in GC and its expression level in plasma in combination with CEA level is a promising diagnostic marker for this malignancy.
Lindqvist, D; Fernström, J; Grudet, C; Ljunggren, L; Träskman-Bendz, L; Ohlsson, L; Westrin, Å
2016-01-01
Preclinical data suggest that chronic stress may cause cellular damage and mitochondrial dysfunction, potentially leading to the release of mitochondrial DNA (mtDNA) into the bloodstream. Major depressive disorder has been associated with an increased amount of mtDNA in leukocytes from saliva samples and blood; however, no previous studies have measured plasma levels of free-circulating mtDNA in a clinical psychiatric sample. In this study, free circulating mtDNA was quantified in plasma samples from 37 suicide attempters, who had undergone a dexamethasone suppression test (DST), and 37 healthy controls. We hypothesized that free circulating mtDNA would be elevated in the suicide attempters and would be associated with hypothalamic–pituitary–adrenal (HPA)-axis hyperactivity. Suicide attempters had significantly higher plasma levels of free-circulating mtDNA compared with healthy controls at different time points (pre- and post-DST; all P-values<2.98E−12, Cohen's d ranging from 2.55 to 4.01). Pre-DST plasma levels of mtDNA were positively correlated with post-DST cortisol levels (rho=0.49, P<0.003). Suicide attempters may have elevated plasma levels of free-circulating mtDNA, which are related to impaired HPA-axis negative feedback. This peripheral index is consistent with an increased cellular or mitochondrial damage. The specific cells and tissues contributing to plasma levels of free-circulating mtDNA are not known, as is the specificity of this finding for suicide attempters. Future studies are needed in order to better understand the relevance of increased free-circulating mtDNA in relation to the pathophysiology underlying suicidal behavior and depression. PMID:27922635
Plasma biomarkers associated with the apolipoprotein E genotype and Alzheimer disease.
Soares, Holly D; Potter, William Z; Pickering, Eve; Kuhn, Max; Immermann, Frederick W; Shera, David M; Ferm, Mats; Dean, Robert A; Simon, Adam J; Swenson, Frank; Siuciak, Judith A; Kaplow, June; Thambisetty, Madhav; Zagouras, Panayiotis; Koroshetz, Walter J; Wan, Hong I; Trojanowski, John Q; Shaw, Leslie M
2012-10-01
A blood-based test that could be used as a screen for Alzheimer disease (AD) may enable early intervention and better access to treatment. To apply a multiplex immunoassay panel to identify plasma biomarkers of AD using plasma samples from the Alzheimer's Disease Neuroimaging Initiative cohort. Cohort study. The Biomarkers Consortium Alzheimer's Disease Plasma Proteomics Project. Plasma samples at baseline and at 1 year were analyzed from 396 (345 at 1 year) patients with mild cognitive impairment, 112 (97 at 1 year) patients with AD, and 58 (54 at 1 year) healthy control subjects. Multivariate and univariate statistical analyses were used to examine differences across diagnostic groups and relative to the apolipoprotein E (ApoE) genotype. Increased levels of eotaxin 3, pancreatic polypeptide, and N-terminal protein B-type brain natriuretic peptide were observed in patients, confirming similar changes reported in cerebrospinal fluid samples of patients with AD and MCI. Increases in tenascin C levels and decreases in IgM and ApoE levels were also observed. All participants with Apo ε3/ε4 or ε4/ε4 alleles showed a distinct biochemical profile characterized by low C-reactive protein and ApoE levels and by high cortisol, interleukin 13, apolipoprotein B, and gamma interferon levels. The use of plasma biomarkers improved specificity in differentiating patients with AD from controls, and ApoE plasma levels were lowest in patients whose mild cognitive impairment had progressed to dementia. Plasma biomarker results confirm cerebrospinal fluid studies reporting increased levels of pancreatic polypeptide and N-terminal protein B-type brain natriuretic peptide in patients with AD and mild cognitive impairment. Incorporation of plasma biomarkers yielded high sensitivity with improved specificity, supporting their usefulness as a screening tool. The ApoE genotype was associated with a unique biochemical profile irrespective of diagnosis, highlighting the importance of genotype on blood protein profiles.
Plasma catecholamines and plasma corticosterone following restraint stress in juvenile alligators.
Lance, V A; Elsey, R M
1999-05-01
Ten juvenile alligators, mean body mass 793 g, hatched from artificially incubated eggs and raised under controlled conditions, were held out of water with their jaws held closed for 48 hr. An initial blood sample was taken and further samples collected at 1, 2, 4, 8, 24, and 48 hr. Epinephrine, norepinephrine, and dopamine were measured in plasma aliquots of 1.5 ml using high pressure liquid chromatography with electrochemical detection. Corticosterone was measured by radioimmunoassay. Plasma glucose was measured using the Trinder method and plasma calcium, cholesterol, and triglycerides were measured in an autoanalyzer. Epinephrine was about 4 ng/ml at the initial bleed, but declined steadily to < 0.4 ng/ml by 24 hr. Norepinephrine was also about 4 ng/ml at the initial bleed, but rose to over 8 ng/ml at 1 hr, and then declined to < 0.2 ng/ml at 24 hr. A second, but smaller increase in plasma norepinephrine was seen at 48 hr. Plasma dopamine was low at the initial bleed (< 0.7 ng/ml), rose to over 8 ng/ml at 1 hr, then declined to < 0.2 ng/ml. Plasma corticosterone rose progressively for the first 4 hr, declined at 8 hr and 24 hr, then rose again at 48 hr. Plasma glucose rose significantly by 24 hr and remained elevated for 48 hr. Plasma calcium increased at 1, 2, and 4 hr then returned to levels not significantly different from the initial sample at 24 and 48 hr. The white blood cells showed changes indicating immune system suppression. By the end of the treatment the hetorophil/lymphocyte ratio increased to 4.7. These results suggest that handling alligators, taking multiple blood samples, and keeping them restrained for more than 8 hr is a severe stress to the animals.
Cui, Dong; Han, GuangWei; Shang, YongGang; Mu, LiJun; Long, QingZhi; Du, YueFeng
2015-01-01
Prostatitis is a common disease in urology departments. Prostatic zinc accumulation is connected with the secretory function of the prostate, and zinc concentrations present in prostatic diseases differ greatly from the normal level. Studies have investigated the effect of chronic prostatitis on zinc concentration of prostatic fluid and seminal plasma, but have shown inconsistent results. Hence, we performed a systematic literature review and meta-analysis to assess the effect of chronic prostatitis on the zinc concentration of prostatic fluid and seminal plasma. Systematic literature searches were conducted with PubMed, Embase, Science Direct/Elsevier, CNKI and the Cochrane Library up to March 2015 for case-control studies that involved the relationship between chronic prostatitis and zinc concentration of prostatic fluid and seminal plasma. Meta-analysis was performed with Review Manager and Stata software. Standard mean differences (SMDs) of zinc concentration were identified with 95% confidence intervals (95% CIs) in a random- or fixed-effects model. Our results illustrated that the zinc concentrations in prostatic fluid and seminal plasma from chronic prostatitis patients were significantly lower than normal controls (SMD [95% CI] -246.71 [-347.97, -145.44], -20.74 [-35.11, -6.37], respectively). The sample size of each study was relatively small, and a total of 731 chronic prostatitis patients and 574 normal controls were investigated in all fourteen studies. Several studies related to the subject were excluded due to lack of control data or means and standard deviations. The present study illustrates that there was a significant negative effect of chronic prostatitis on zinc concentrations of prostatic fluid and seminal plasma. Further studies with larger sample sizes are needed to better illuminate the negative impact of chronic prostatitis on zinc concentrations.
Velez-Montoya, Raul; Clapp, Carmen; Rivera, Jose Carlos; Garcia-Aguirre, Gerardo; Morales-Cantón, Virgilio; Fromow-Guerra, Jans; Guerrero-Naranjo, Jose Luis; Quiroz-Mercado, Hugo
2010-01-01
Purpose: To measure vitreous, aqueous, subretinal fluid and plasma levels of vascular endothelial growth factor in late stages of retinopathy of prematurity. Methods: Interventional study. We enrolled patients with clinical diagnoses of bilateral stage V retinopathy of prematurity, confirmed by b-scan ultrasound and programmed for vitrectomy. During surgery we took samples from blood, aqueous, vitreous, and subretinal fluids. The vascular endothelial growth factor concentration in each sample was measured by ELISA reaction. A control sample of aqueous, vitreous and blood was taken from patients with congenital cataract programmed for phacoemulsification. For statistical analysis, a Mann–Whitney and a Wilcoxon W test was done with a significant P value of 0.05. Results: We took samples of 16 consecutive patients who met the inclusion criteria. The vascular endothelial growth factor levels in the study group were: aqueous, 76.81 ± 61.89 pg/mL; vitreous, 118.53 ± 65.87 pg/mL; subretinal fluid, 1636.58 ± 356.47 pg/mL; and plasma, 74.64 ± 43.94 pg/mL. There was a statistical difference between the study and the control group (P < 0.001) in the aqueous and vitreous samples. Conclusion: Stage 5 retinopathy of prematurity has elevated intraocular levels of vascular endothelial growth factor, which remains high despite severe retinal lesion. There was no statistical difference in plasma levels of the molecule between the control and study group. PMID:20856587
Zhang, Rufang; Yang, Deyu; Zhou, Chanjuan; Cheng, Ke; Liu, Zhao; Chen, Liang; Fang, Liang; Xie, Peng
2012-08-15
Western blot analysis is a commonly used technique for determining specific protein levels in clinical samples. For normalization of protein levels in Western blot, a suitable loading control is required. On account of its relatively high and constant expression, β-actin has been widely employed in Western blot of cell cultures and tissue extracts. However, β-actin's presence in human plasma and this protein's putative role as a plasma-based loading control for Western blot analysis remain unknown. In this study, an enzyme-linked immunosorbent assay was used to determine the concentration of β-actin in human plasma, which is 6.29±0.54 ng/ml. In addition, the linearity of β-actin immunostaining and loaded protein amount was evaluated by Western blot, and a fine linearity (R²=0.974±0.012) was observed. Furthermore, the expression of plasma β-actin in major depressive disorder subjects and healthy controls was compared. The data revealed no statistically significant difference between these two groups. Moreover, the total coefficient of variation for β-actin expression in the two groups was 9.2±1.2%. These findings demonstrate that β-actin is present in human plasma and may possibly be used as a suitable loading control for plasma-based Western blot analysis in major depressive disorder. Copyright © 2012 Elsevier Inc. All rights reserved.
Din, Li; Li, Limin; Tao, Ping; Yang, Jin; Zhang, Zhengxing
2002-02-05
A highly sensitive method for quantitation of tamsulosin in human plasma using 1-(2,6-dimethyl-3-hydroxylphenoxy)-2-(3,4-methoxyphenylethylamino)-propane hydrochloride as the internal standard (I.S.) was established using liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS). After alkalization with saturated sodium bicarbonate, plasma were extracted by ethyl acetate and separated by HPLC on a C18 reversed-phase column using a mobile phase of methanol-water-acetic acid-triethylamine (620:380:1.5:1.5, v/v). Analytes were quantitated using positive electrospray ionization in a quadrupole spectrometer. LC-ESI-MS was performed in the selected ion monitoring (SIM) mode using target ions at m/z 228 for tamsulosin and m/z 222 for the I.S. Calibration curves, which were linear over the range 0.2-30 ng/ml, were analyzed contemporaneously with each batch of samples, along with low (0.5 ng/ml), medium (3 ng/ml) and high (30 ng/ml) quality control samples. The intra- and inter-assay variability ranged from 2.14 to 8.87% for the low, medium and high quality control samples. The extraction recovery of tamsulosin from plasma was in the range of 84.2-94.5%. The method has been used successfully to study tamsulosin pharmacokinetics in adult humans.
Kwok, Wai Him; Choi, Timmy L S; Kwok, Karen Y; Chan, George H M; Wong, Jenny K Y; Wan, Terence S M
2016-06-17
The high sensitivity of ultra high performance liquid chromatography coupled with high resolution mass spectrometry (UHPLC-HRMS) allows the identification of many prohibited substances without pre-concentration, leading to the development of simple and fast 'dilute-and-shoot' methods for doping control for human and equine sports. While the detection of polar drugs in plasma and urine is difficult using liquid-liquid or solid-phase extraction as these substances are poorly extracted, the 'dilute-and-shoot' approach is plausible. This paper describes a 'dilute-and-shoot' UHPLC-HRMS screening method to detect 46 polar drugs in equine urine and plasma, including some angiotensin-converting enzyme (ACE) inhibitors, sympathomimetics, anti-epileptics, hemostatics, the new doping agent 5-aminoimidazole-4-carboxamide-1-β-d-ribofuranoside (AICAR), as well as two threshold substances, namely dimethyl sulfoxide and theobromine. For plasma, the sample (200μL) was protein precipitated using trichloroacetic acid, and the resulting supernatant was diluted using Buffer A with an overall dilution factor of 3. For urine, the sample (20μL) was simply diluted 50-fold with Buffer A. The diluted plasma or urine sample was then analysed using a UHPLC-HRMS system in full-scan ESI mode. The assay was validated for qualitative identification purpose. This straightforward and reliable approach carried out in combination with other screening procedures has increased the efficiency of doping control analysis in the laboratory. Moreover, since the UHPLC-HRMS data were acquired in full-scan mode, the method could theoretically accommodate an unlimited number of existing and new doping agents, and would allow a retrospectively search for drugs that have not been targeted at the time of analysis. Copyright © 2016 Elsevier B.V. All rights reserved.
Processing and Characterization of Porous Ti2AlC with Controlled Porosity and Pore Size
2012-09-11
fabricated by spark plasma sintering , were also characterized. The effects of porosity and/or pore size on the room temperature elastic moduli...pressureless- sintered without NaCl pore former, or fabricated by spark plasma sintering , were also characterized. The effects of porosity and/or pore size...as well as several samples sintered using spark plasma sintering (SPS). Furthermore, we demon- strate that the developed methodology can be implemented
Chunhui, Yang; Guohui, Bian; Hong, Yang; Xiaopu, Xiao; Zherong, Bai; Mingyuan, Wang; Xinsheng, Zhang; Juanjuan, Wang; Changqing, Li; Wuping, Li
2013-12-01
Pathogen reduction technology is an important process in the blood safety system, including solvent/detergent treatment, filtration and methylene blue-photochemical technology (MB-PCT). To investigate the quality of MB-PCT-treated plasma, plasma samples from four Chinese blood centers were analyzed over 12 months of storage to determine the recovery of activities and levels of various plasma proteins. Ten plasma units each from the Suzhou, Yancheng, Chongqing and Shandong blood centers were divided into two aliquots. One was subjected to treatment with one of two methylene blue-photochemical technology instruments and the other was used as control. The treated and untreated sample pairs were stored at -30°C. The recovery rates of coagulation factors, inhibitor proteins, total protein, immunoglobulins, and complement proteins were measured at different time points after storage. The mean recovery of most proteins exceeded 80% after MB treatment. The exceptions were factor XI and fibrinogen, of which only 71.3-74% and 69.0-92.3% were retained during storage. The two equipment types differed in terms of residual MB concentration in the plasma samples (0.18 μM and 0.29 μM, respectively). They had similar protein recovery rates at 0.5 month but differed at later time points. The four blood centers differed significantly with regard to factor II, V, VIII and fibrinogen activities. Only the samples from the Shandong blood center met the methylene blue treated fresh frozen plasma requirement. The major factor that influenced the quality of the MB-FFP samples was the time taken between blood collection and storage. Methylene blue treated plasma showed reduced coagulation factor (CF) activity and protein levels. The MB treatment-induced damage to the proteins was acceptable at the four Chinese blood centers, but the quality of the MB-treated plasma in general was not satisfactory. The main factor affecting plasma quality may be the duration of the collection and processing. Copyright © 2013 Elsevier Ltd. All rights reserved.
Cawello, Willi; Schäfer, Carina
2014-08-01
Frequent plasma sampling to monitor pharmacokinetic (PK) profile of antiepileptic drugs (AEDs), is invasive, costly and time consuming. For drugs with a well-defined PK profile, such as AED lacosamide, equations can accurately approximate PK parameters from one steady-state plasma sample. Equations were derived to approximate steady-state peak and trough lacosamide plasma concentrations (Cpeak,ss and Ctrough,ss, respectively) and area under concentration-time curve during dosing interval (AUCτ,ss) from one plasma sample. Lacosamide (ka: ∼2 h(-1); ke: ∼0.05 h(-1), corresponding to half-life of 13 h) was calculated to reach Cpeak,ss after ∼1 h (tmax,ss). Equations were validated by comparing approximations to reference PK parameters obtained from single plasma samples drawn 3-12h following lacosamide administration, using data from double-blind, placebo-controlled, parallel-group PK study. Values of relative bias (accuracy) between -15% and +15%, and root mean square error (RMSE) values≤15% (precision) were considered acceptable for validation. Thirty-five healthy subjects (12 young males; 11 elderly males, 12 elderly females) received lacosamide 100mg/day for 4.5 days. Equation-derived PK values were compared to reference mean Cpeak,ss, Ctrough,ss and AUCτ,ss values. Equation-derived PK data had a precision of 6.2% and accuracy of -8.0%, 2.9%, and -0.11%, respectively. Equation-derived versus reference PK values for individual samples obtained 3-12h after lacosamide administration showed correlation (R2) range of 0.88-0.97 for AUCτ,ss. Correlation range for Cpeak,ss and Ctrough,ss was 0.65-0.87. Error analyses for individual sample comparisons were independent of time. Derived equations approximated lacosamide Cpeak,ss, Ctrough,ss and AUCτ,ss using one steady-state plasma sample within validation range. Approximated PK parameters were within accepted validation criteria when compared to reference PK values. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Melikechi, Noureddine; Markushin, Yuri; Connolly, Denise C.; Lasue, Jeremie; Ewusi-Annan, Ebo; Makrogiannis, Sokratis
2016-09-01
Epithelial ovarian cancer (EOC) mortality rates are strongly correlated with the stage at which it is diagnosed. Detection of EOC prior to its dissemination from the site of origin is known to significantly improve the patient outcome. However, there are currently no effective methods for early detection of the most common and lethal subtype of EOC. We sought to determine whether laser-induced breakdown spectroscopy (LIBS) and classification techniques such as linear discriminant analysis (LDA) and random forest (RF) could classify and differentiate blood plasma specimens from transgenic mice with ovarian carcinoma and wild type control mice. Herein we report results using this approach to distinguish blood plasma samples obtained from serially bled (at 8, 12, and 16 weeks) tumor-bearing TgMISIIR-TAg transgenic and wild type cancer-free littermate control mice. We have calculated the age-specific accuracy of classification using 18,000 laser-induced breakdown spectra of the blood plasma samples from tumor-bearing mice and wild type controls. When the analysis is performed in the spectral range 250 nm to 680 nm using LDA, these are 76.7 (± 2.6)%, 71.2 (± 1.3)%, and 73.1 (± 1.4)%, for the 8, 12 and 16 weeks. When the RF classifier is used, we obtain values of 78.5 (± 2.3)%, 76.9 (± 2.1)% and 75.4 (± 2.0)% in the spectral range of 250 nm to 680 nm, and 81.0 (± 1.8)%, 80.4 (± 2.1)% and 79.6 (± 3.5)% in 220 nm to 850 nm. In addition, we report, the positive and negative predictive values of the classification of the two classes of blood plasma samples. The approach used in this study is rapid, requires only 5 μL of blood plasma, and is based on the use of unsupervised and widely accepted multivariate analysis algorithms. These findings suggest that LIBS and multivariate analysis may be a novel approach for detecting EOC.
Identification of vinculin as a potential plasma marker for age-related macular degeneration.
Kim, Hye-Jung; Woo, Se Joon; Suh, Eui Jin; Ahn, Jeeyun; Park, Ji Hyun; Hong, Hye Kyoung; Lee, Ji Eun; Ahn, Seong Joon; Hwang, Duck Jin; Kim, Ki Woong; Park, Kyu Hyung; Lee, Cheolju
2014-10-08
To identify plasma protein biomarkers for age-related macular degeneration (AMD) using a large-scale quantitative proteomic discovery procedure. Plasma proteomes from 20 exudative AMD patients and 20 healthy control patients were comparatively profiled by four-dimensional liquid chromatography-tandem mass spectrometry (LC-MS/MS). Proteins existing at statistically different levels were validated by enzyme-linked immunosorbent assay (ELISA) and Western blotting in 233 case-controlled samples. Newly discovered plasma biomarkers were further confirmed using in vivo and in vitro experiments. Out of 320 proteins identified, vinculin, protein S100A9, triosephosphate isomerase, protein S100A8, protein Z-dependent protease inhibitor, C-X-C motif chemokine 7, and tenascin X showed significantly differential expression in AMD patient plasma compared to control plasma. Among these, the area under the curve (AUC) for vinculin was 0.871 for discriminating between exudative AMD and controls (n = 201) and 0.879 for discriminating between AMD and controls (n = 233). A proteogenomic combination model using vinculin and two known risk genotypes in ARMS2 and CFH genes additionally provided excellent discrimination of AMD from controls (AUC = 0.916). The plasma level of vinculin was not associated with any confounding clinical variables, such as age, smoking, and other comorbidities. Additionally, vinculin was strongly expressed in retinal pigment epithelial cells of human eyes, and its expression was elevated when exposed to oxidative stress in vitro. Vinculin was identified as a potential plasma biomarker for AMD. The early detection of AMD using novel plasma biomarkers with genetic modeling may enable timely treatment and vision preservation in the elderly. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Role of mycotoxins in herds with and without problems with tail necrosis in neonatal pigs.
Van Limbergen, Tommy; Devreese, Mathias; Croubels, Siska; Broekaert, Nathan; Michiels, Annelies; De Saeger, Sarah; Maes, Dominiek
2017-11-18
This study aimed to investigate a possible involvement of mycotoxins in neonatal tail necrosis in piglets. Ten affected and 10 non-affected farms were selected. Sow feed samples were analysed for the presence of 23 mycotoxins by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Blood plasma samples of sows and their piglets were analysed for the presence of deoxynivalenol (DON), de-epoxydeoxynivalenol, T-2 and HT-2 toxin, zearalenone, alfa-zearalenol, and beta-zearalenol, using LC-MS/MS. Additionally, high-resolution mass spectrometry (HRMS) was performed to detect DON-glucuronide (DON-Glca). There was a significant difference between case herds and control herds for mean DON concentrations in feed and sow plasma. For piglet samples, concentrations of DON were above the limit of quantification of 0.1 ng/ml in only 12 samples. Positive correlations were found between DON concentrations in sow feed and plasma of sows; DON concentration in sow feed and DON-Glca concentration in plasma of sows; and between DON and DON-Glca concentration in sow-plasma. In conclusion, high prevalence of DON in feed samples was found, with significantly higher concentrations in case herds, as well as the presence of DON and DON-Glca in sow plasma. Additional research is needed to identify risk factors, including within-herd factors, associated with neonatal tail necrosis in piglets. © British Veterinary Association (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Krishnan, Shilpa; Karg, Patricia E; Boninger, Michael L; Vodovotz, Yoram; Constantine, Greg; Sowa, Gwendolyn A; Brienza, David M
2016-10-01
To identify changes in concentrations of inflammatory mediators in plasma and urine after traumatic spinal cord injury (SCI) and before the occurrence of a first pressure ulcer. Retrospective; secondary analysis of existing data. Acute hospitalization and inpatient rehabilitation sites at a university medical center. Individuals with a pressure ulcer and plasma samples (n=17) and individuals with a pressure ulcer and urine samples (n=15) were matched by age and plasma/urine sample days to individuals with SCI and no pressure ulcer (N=35). Not applicable. Plasma and urine samples were assayed in patients with SCI, capturing samples within 4 days after the SCI to a week before the formation of the first pressure ulcer. The Wilcoxon signed-rank test was performed to identify changes in the inflammatory mediators between the 2 time points. An increase in concentration of the chemokine interferon-γ-induced protein of 10kd/CXCL10 in plasma (P<.01) and a decrease in concentration of the cytokine interferon-α in urine (P=.01) were observed before occurrence of a first pressure ulcer (∼4d) compared with matched controls. Altered levels of inflammatory mediators in plasma and urine may be associated with pressure ulcer development after traumatic SCI. These inflammatory mediators should be explored as possible biomarkers for identifying individuals at risk for pressure ulcer formation. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Ertan, Nesrin Zeynep; Bozfakioglu, Semra; Ugurel, Elif; Sinan, Mukaddes; Yalcin, Ozlem
2017-01-01
In this study, we investigated the effects of peritoneal dialysis on hemorheological and hematological parameters and their relations with oxidant and antioxidant status of uremic patients. Hemorheological parameters (erythrocyte deformability, erythrocyte aggregation, osmotic deformability, blood and plasma viscosity) were measured in patients with renal insufficiency undergoing peritoneal dialysis (PD) and volunteers. Erythrocyte deformability, osmotic deformability and aggregation in both autologous plasma and 3% dextran 70 were measured by laser diffraction ektacytometry. Enzyme activities of glutathione peroxidase, superoxide dismutase and catalase were studied in erythrocytes; lipid peroxidation was studied by measuring the amount of malondialdehyde in both erythrocytes and plasma samples. Blood viscosity at native hematocrit was significantly lower in PD patients at all measured shear rates compared to controls, but it was high in PD patients at corrected (45%) hematocrit. Erythrocyte deformability did not show any difference between the two groups. Osmotic deformability was significantly lower in PD patients compared to controls. Aggregation index values were significantly high in PD patients in plasma Catalase and glutathione peroxidase activities in erythrocytes were decreased in PD patients whereas superoxide dismutase activity was increased compared to controls. Malondialdehyde was significantly increased in erythrocytes and plasma samples of PD patients which also shows correlations with aggregation parameters. It has been concluded that erythrocytes in PD patients are more prone to aggregation and this tendency could be influenced by lipid peroxidation activity in patient's plasma. These results imply that uremic conditions, loss of plasma proteins and an increased risk of oxidative stress because of decreasing levels of antioxidant enzymes affect erythrocyte rheology during peritoneal dialysis. This level of distortion may have crucial effects, impairing the blood flow dynamics and causing inadequate microcirculatory perfusion.
Türkcü, Fatih Mehmet; Yüksel, Harun; Yüksel, Hatice; Sahin, Alparslan; Cinar, Yasin; Cingü, Abdullah Kürşat; Sahin, Muhammed; Caça, Ihsan
2014-01-01
The objective of this work is to evaluate plasma total antioxidant capacity (TAC), total oxidant status (TOS), and dehydroepiandrosterone sulphate (DHEA-S) levels in patients diagnosed with acute central serous chorioretinopathy (CSCR) and control samples. The TAC, TOS, and DHEA-S levels were assessed in the plasma of 46 CSCR patients and compared with 40 control samples. The TAC level was 1.16 ± 0.08 and 1.20 ± 0.09 mmol Trolox eq./l; TOS level was 28.77 ± 33.33 and 19.95 ± 10.42 μmol H202/l; DHEA-S level was 203.79 ± 84.75 μg/dl and 249.36 ± 122.93 μg/dl in the CSCR group and in the control group, respectively. The plasma TAC and DHEA-S values were significantly lower in the CSCR group than in the control group (p = 0.027 and p = 0.046, respectively). There was no significant difference between the CSCR and the control groups in terms of age, gender, and TOS levels (p > 0.05). We demonstrated that the levels of plasma DHEA-S and antioxidative parameters were reduced in CSCR. Our results suggest that the antioxidant defense system may be inadequate or corrupted in CSCR. Reduced DHEA-S level is one of the factors that trigger this insufficiency.
Cao, Yupin; Deng, Biyang; Yan, Lizhen; Huang, Hongli
2017-05-15
An environmentally friendly and highly efficient gas pressure-assisted sample introduction system (GPASIS) was developed for inductively-coupled plasma mass spectrometry. A GPASIS consisting of a gas-pressure control device, a customized nebulizer, and a custom-made spray chamber was fabricated. The advantages of this GPASIS derive from its high nebulization efficiencies, small sample volume requirements, low memory effects, good precision, and zero waste emission. A GPASIS can continuously, and stably, nebulize 10% NaCl solution for more than an hour without clogging. Sensitivity, detection limits, precision, long-term stability, double charge and oxide ion levels, nebulization efficiencies, and matrix effects of the sample introduction system were evaluated. Experimental results indicated that the performance of this GPASIS, was equivalent to, or better than, those obtained by conventional sample introduction systems. This GPASIS was successfully used to determine Cd and Pb by ICP-MS in human plasma. Copyright © 2017 Elsevier B.V. All rights reserved.
Kuwabara, Hitoshi; Yamasue, Hidenori; Koike, Shinsuke; Inoue, Hideyuki; Kawakubo, Yuki; Kuroda, Miho; Takano, Yosuke; Iwashiro, Norichika; Natsubori, Tatsunobu; Aoki, Yuta; Kano, Yukiko; Kasai, Kiyoto
2013-01-01
Clinical diagnosis and severity of autism spectrum disorders (ASD) are determined by trained clinicians based on clinical evaluations of observed behaviors. As such, this approach is inevitably dependent on the expertise and subjective assessment of those administering the clinical evaluations. There is a need to identify objective biological markers associated with diagnosis or clinical severity of the disorder. To identify novel candidate metabolites as potential biomarkers for ASD, the current study applied capillary electrophoresis time-of-flight mass spectroscopy (CE-TOFMS) for high-throughput profiling of metabolite levels in the plasma of 25 psychotropic-naïve adult males with high-functioning ASD and 28 age-matched typically-developed control subjects. Ten ASD participants and ten age-matched controls were assigned in the first exploration set, while 15 ASD participants and 18 controls were included in the second replication set. By CE-TOFMS analysis, a total of 143 metabolites were detected in the plasma of the first set. Of these, 17 metabolites showed significantly different relative areas between the ASD participants and the controls (p<0.05). Of the 17 metabolites, we consistently found that the ASD participants had significantly high plasma levels of arginine (p = 0.024) and taurine (p = 0.018), and significantly low levels of 5-oxoproline (p<0.001) and lactic acid (p = 0.031) compared with the controls in the second sample set. Further confirmatory analysis using quantification of absolute metabolite concentrations supported the robustness of high arginine (p = 0.001) and low lactic acid (p = 0.003) in the combined sample (n = 53). The present study identified deviated plasma metabolite levels associated with oxidative stress and mitochondrial dysfunction in individuals with ASD.
Kuwabara, Hitoshi; Yamasue, Hidenori; Koike, Shinsuke; Inoue, Hideyuki; Kawakubo, Yuki; Kuroda, Miho; Takano, Yosuke; Iwashiro, Norichika; Natsubori, Tatsunobu; Aoki, Yuta; Kano, Yukiko; Kasai, Kiyoto
2013-01-01
Clinical diagnosis and severity of autism spectrum disorders (ASD) are determined by trained clinicians based on clinical evaluations of observed behaviors. As such, this approach is inevitably dependent on the expertise and subjective assessment of those administering the clinical evaluations. There is a need to identify objective biological markers associated with diagnosis or clinical severity of the disorder. To identify novel candidate metabolites as potential biomarkers for ASD, the current study applied capillary electrophoresis time-of-flight mass spectroscopy (CE-TOFMS) for high-throughput profiling of metabolite levels in the plasma of 25 psychotropic-naïve adult males with high-functioning ASD and 28 age-matched typically-developed control subjects. Ten ASD participants and ten age-matched controls were assigned in the first exploration set, while 15 ASD participants and 18 controls were included in the second replication set. By CE-TOFMS analysis, a total of 143 metabolites were detected in the plasma of the first set. Of these, 17 metabolites showed significantly different relative areas between the ASD participants and the controls (p<0.05). Of the 17 metabolites, we consistently found that the ASD participants had significantly high plasma levels of arginine (p = 0.024) and taurine (p = 0.018), and significantly low levels of 5-oxoproline (p<0.001) and lactic acid (p = 0.031) compared with the controls in the second sample set. Further confirmatory analysis using quantification of absolute metabolite concentrations supported the robustness of high arginine (p = 0.001) and low lactic acid (p = 0.003) in the combined sample (n = 53). The present study identified deviated plasma metabolite levels associated with oxidative stress and mitochondrial dysfunction in individuals with ASD. PMID:24058493
Mengoli, Carlo; Springer, Jan; Bretagne, Stéphane; Cuenca-Estrella, Manuel; Klingspor, Lena; Lagrou, Katrien; Melchers, Willem J. G.; Morton, C. Oliver; Barnes, Rosemary A.; Donnelly, J. Peter; White, P. Lewis
2015-01-01
The use of serum or plasma for Aspergillus PCR testing facilitates automated and standardized technology. Recommendations for serum testing are available, and while serum and plasma are regularly considered interchangeable for use in fungal diagnostics, differences in galactomannan enzyme immunoassay (GM-EIA) performance have been reported and are attributed to clot formation. Therefore, it is important to assess plasma PCR testing to determine if previous recommendations for serum are applicable and also to compare analytical performance with that of serum PCR. Molecular methods testing serum and plasma were compared through multicenter distribution of quality control panels, with additional studies to investigate the effect of clot formation and blood fractionation on DNA availability. Analytical sensitivity and time to positivity (TTP) were compared, and a regression analysis was performed to identify variables that enhanced plasma PCR performance. When testing plasma, sample volume, preextraction-to-postextraction volume ratio, PCR volume, duplicate testing, and the use of an internal control for PCR were positively associated with performance. When whole-blood samples were spiked and then fractionated, the analytical sensitivity and TTP were superior when testing plasma. Centrifugation had no effect on DNA availability, whereas the presence of clot material significantly lowered the concentration (P = 0.028). Technically, there are no major differences in the molecular processing of serum and plasma, but the formation of clot material potentially reduces available DNA in serum. During disease, Aspergillus DNA burdens in blood are often at the limits of PCR performance. Using plasma might improve performance while maintaining the methodological simplicity of serum testing. PMID:26085614
Loeffler, Juergen; Mengoli, Carlo; Springer, Jan; Bretagne, Stéphane; Cuenca-Estrella, Manuel; Klingspor, Lena; Lagrou, Katrien; Melchers, Willem J G; Morton, C Oliver; Barnes, Rosemary A; Donnelly, J Peter; White, P Lewis
2015-09-01
The use of serum or plasma for Aspergillus PCR testing facilitates automated and standardized technology. Recommendations for serum testing are available, and while serum and plasma are regularly considered interchangeable for use in fungal diagnostics, differences in galactomannan enzyme immunoassay (GM-EIA) performance have been reported and are attributed to clot formation. Therefore, it is important to assess plasma PCR testing to determine if previous recommendations for serum are applicable and also to compare analytical performance with that of serum PCR. Molecular methods testing serum and plasma were compared through multicenter distribution of quality control panels, with additional studies to investigate the effect of clot formation and blood fractionation on DNA availability. Analytical sensitivity and time to positivity (TTP) were compared, and a regression analysis was performed to identify variables that enhanced plasma PCR performance. When testing plasma, sample volume, preextraction-to-postextraction volume ratio, PCR volume, duplicate testing, and the use of an internal control for PCR were positively associated with performance. When whole-blood samples were spiked and then fractionated, the analytical sensitivity and TTP were superior when testing plasma. Centrifugation had no effect on DNA availability, whereas the presence of clot material significantly lowered the concentration (P = 0.028). Technically, there are no major differences in the molecular processing of serum and plasma, but the formation of clot material potentially reduces available DNA in serum. During disease, Aspergillus DNA burdens in blood are often at the limits of PCR performance. Using plasma might improve performance while maintaining the methodological simplicity of serum testing. Copyright © 2015 Loeffler et al.
Measuring xenon in human plasma and blood by gas chromatography/mass spectrometry.
Thevis, Mario; Piper, Thomas; Geyer, Hans; Thomas, Andreas; Schaefer, Maximilian S; Kienbaum, Peter; Schänzer, Wilhelm
2014-07-15
Due to the favorable pharmacokinetic properties and minimal side effects of xenon, its use in modern anesthesia has been well accepted, and recent studies further demonstrated the intra- and postoperative neuro-, cardio-, and reno-protective action of the noble gas. Since the production of the hypoxia-inducible factor 1α (HIF-1α) and its downstream effector erythropoietin as well as noradrenalin reuptake inhibition have been found to play key roles in this context, the question arose as to whether the use of xenon is a matter for doping controls and preventive doping research. The aim of the present study was hence to evaluate whether the (ab)use of xenon can be detected from doping control samples with the instrumentation commonly available in sports drug testing laboratories. Plasma was saturated with xenon according to reported protocols, and the target analyte was measured by means of gas chromatography/time-of-flight and triple quadrupole mass spectrometry with headspace injection. Recording the accurate mass of three major xenon isotopes at m/z 128.9048, 130.9045 and 131.9042 allowed for the unequivocal identification of the analyte and the detection assay was characterized concerning limit of detection (LOD), intraday precision, and specificity as well as analyte recovery under different storage conditions. Xenon was detected in fortified plasma samples with detection limits of approximately 0.5 nmol/mL to 50 nmol/mL, depending on the type of mass spectrometer used. The method characteristics of intraday precision (coefficient of variation <20%) and specificity demonstrated the fitness-for-purpose of the analytical approach to unambiguously detect xenon at non-physiological concentrations in human plasma and blood. Eventually, authentic plasma and blood samples collected pre-, intra-, and post-operative (4, 8, and 24 h) were positively analyzed after storage for up to 30 h, and provided proof-of-concept for the developed assay. If relevant to doping controls, xenon can be determined from plasma and blood samples, i.e. common specimens of routine sports drug testing in the context of Athlete Biological Passport (ABP) analyses. Optimization of sampling and analytical procedures will allow the detection limit to be further improved and potentially enable accurate quantification of the anesthetic agent. Copyright © 2014 John Wiley & Sons, Ltd.
Murray, M; Murphy, C A; Ross, L L; Haun, F
1994-01-01
The fasciculus retroflexus (FR) is the major pathway by which the medial and lateral habenular nuclei project to the interpeduncular nucleus (IPN) and ventral tegmentum. Recent work has suggested that the habenula-interpeduncular system may be involved in the regulation of states of arousal. Bilateral FR lesions have been shown to disrupt chronically, and habenula transplants have been shown to restore normal sleep patterns in rats [J. NeuroscL, 12 (1992) 3282-3290]. In this study, we examined whether FR lesions and habenula cell transplants would also modify chronically the circulating plasma levels of the stress-related hormones, norepinephrine (NE), epinephrine (EPI) and corticosterone. When plasma samples were obtained via retro-orbital eye-bleed during anesthesia, animals with FR lesions had significantly increased levels of plasma NE, EPI and corticosterone 2-3 months postoperatively compared to unoperated controls. Transplants of embryonic habenula cells placed near the denervated IPN in FR-lesioned animals restored levels of NE and EPI to normal, but did not attenuate elevated corticosterone levels. When plasma samples were obtained in conscious animals via indwelling arterial cannulae, FR-lesioned rats likewise exhibited increased basal levels of corticosterone but plasma levels of catecholamines were similar to those of unoperated controls. Differences in our results obtained using the two methods of blood sampling may be explained by the effects of anesthesia and stress associated with the eye-bleed method. Thus, the effect of FR lesions in increasing plasma levels of catecholamines may not reflect a difference in basal hormone levels, but a heightened sympathetic adrenomedullary response to stress. While these results indicate that the integrity of the habenular efferent pathway is important in modulating circulating levels of hormones associated with the stress response, two separate mechanisms appear to control its interactions with sympathetic-adrenal medullary and adrenocortical pathways.
Standardized protocols for quality control of MRM-based plasma proteomic workflows.
Percy, Andrew J; Chambers, Andrew G; Smith, Derek S; Borchers, Christoph H
2013-01-04
Mass spectrometry (MS)-based proteomics is rapidly emerging as a viable technology for the identification and quantitation of biological samples, such as human plasma--the most complex yet commonly employed biofluid in clinical analyses. The transition from a qualitative to quantitative science is required if proteomics is going to successfully make the transition to a clinically useful technique. MS, however, has been criticized for a lack of reproducibility and interlaboratory transferability. Currently, the MS and plasma proteomics communities lack standardized protocols and reagents to ensure that high-quality quantitative data can be accurately and precisely reproduced by laboratories across the world using different MS technologies. Toward addressing this issue, we have developed standard protocols for multiple reaction monitoring (MRM)-based assays with customized isotopically labeled internal standards for quality control of the sample preparation workflow and the MS platform in quantitative plasma proteomic analyses. The development of reference standards and their application to a single MS platform is discussed herein, along with the results from intralaboratory tests. The tests highlighted the importance of the reference standards in assessing the efficiency and reproducibility of the entire bottom-up proteomic workflow and revealed errors related to the sample preparation and performance quality and deficits of the MS and LC systems. Such evaluations are necessary if MRM-based quantitative plasma proteomics is to be used in verifying and validating putative disease biomarkers across different research laboratories and eventually in clinical laboratories.
Plasma metabolomics for the diagnosis and prognosis of H1N1 influenza pneumonia.
Banoei, Mohammad M; Vogel, Hans J; Weljie, Aalim M; Kumar, Anand; Yende, Sachin; Angus, Derek C; Winston, Brent W
2017-04-19
Metabolomics is a tool that has been used for the diagnosis and prognosis of specific diseases. The purpose of this study was to examine if metabolomics could be used as a potential diagnostic and prognostic tool for H1N1 pneumonia. Our hypothesis was that metabolomics can potentially be used early for the diagnosis and prognosis of H1N1 influenza pneumonia. 1 H nuclear magnetic resonance spectroscopy and gas chromatography-mass spectrometry were used to profile the metabolome in 42 patients with H1N1 pneumonia, 31 ventilated control subjects in the intensive care unit (ICU), and 30 culture-positive plasma samples from patients with bacterial community-acquired pneumonia drawn within the first 24 h of hospital admission for diagnosis and prognosis of disease. We found that plasma-based metabolomics from samples taken within 24 h of hospital admission can be used to discriminate H1N1 pneumonia from bacterial pneumonia and nonsurvivors from survivors of H1N1 pneumonia. Moreover, metabolomics is a highly sensitive and specific tool for the 90-day prognosis of mortality in H1N1 pneumonia. This study demonstrates that H1N1 pneumonia can create a quite different plasma metabolic profile from bacterial culture-positive pneumonia and ventilated control subjects in the ICU on the basis of plasma samples taken within 24 h of hospital/ICU admission, early in the course of disease.
Chao de la Barca, Juan Manuel; Bakhta, Oussama; Kalakech, Hussein; Simard, Gilles; Tamareille, Sophie; Catros, Véronique; Callebert, Jacques; Gadras, Cédric; Tessier, Lydie; Reynier, Pascal; Prunier, Fabrice; Mirebeau-Prunier, Delphine
2016-09-24
Remote ischemic preconditioning (RIPC) is an attractive therapeutic procedure for protecting the heart against ischemia/reperfusion injury. Despite evidence of humoral mediators transported through the circulation playing a critical role, their actual identities so far remain unknown. We sought to identify plasmatic RIPC-induced metabolites that may play a role. Rat plasma samples from RIPC and control groups were analyzed using a targeted metabolomic approach aimed at measuring 188 metabolites. Principal component analysis and orthogonal partial least-squares discriminant analysis were used to identify the metabolites that discriminated between groups. Plasma samples from 50 patients subjected to RIPC were secondarily explored to confirm the results obtained in rats. Finally, a combination of the metabolites that were significantly increased in both rat and human plasma was injected prior to myocardial ischemia/reperfusion in rats. In the rat samples, 124 molecules were accurately quantified. Six metabolites (ornithine, glycine, kynurenine, spermine, carnosine, and serotonin) were the most significant variables for marked differentiation between the RIPC and control groups. In human plasma, analysis confirmed ornithine decrease and kynurenine and glycine increase following RIPC. Injection of the glycine and kynurenine alone or in combination replicated the protective effects of RIPC seen in rats. We have hereby reported significant variations in a cocktail of amino acids and biogenic amines after remote ischemic preconditioning in both rat and human plasma. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01390129. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
The effect of plasma surface treatment on the bioactivity of titanium implant materials (in vitro)
Abdelrahim, Ramy A.; Badr, Nadia A.; Baroudi, Kusai
2016-01-01
Background: The surface of an implantable biomaterial plays a very important role in determining the biocompatibility, osteoinduction, and osteointegration of implants because it is in intimate contact with the host bone and soft tissues. Objective: This study was aimed to assess the effect of plasma surface treatment on the bioactivity of titanium alloy (Ti–6Al–4V). Materials and Methods: Fifteen titanium alloy samples were used in this study. The samples were divided into three groups (with five samples in each group). Five samples were kept untreated and served as control (group A). Another five plasma samples were sprayed for nitrogen ion implantation on their surfaces (group B) and the last five samples were pre-etched with acid before plasma treatment (group C). All the investigated samples were immersed for 7 days in Hank's balanced salt solution (HBSS) which was used as a simulating body fluid (SBF) at pH 7.4 and 37°C. HBSS was renewed every 3 days. The different surfaces were characterized by X-ray diffraction (XRD), Atomic Force Microscopy (AFM), Scanning Electron Microscopy (SEM), Energy-dispersive X-ray spectroscopy (EDXA), and Fourier Transformation Infrared Spectroscopy (FTIR). Results: Nitriding of Ti-alloy samples via plasma nitrogen ion implantation increased the bioactivity of titanium. Moreover, the surface topography affected the chemical structure of the formed apatite. Increasing the surface roughness enhanced the bioactivity of the implant material. Conclusions: Nitridation can be exploited as an effective way to promote the formation of bone-like material on the implant surface. PMID:27011927
Hasegawa, Yuri; Miura, Kiyonori; Higashijima, Ai; Abe, Shuhei; Miura, Shoko; Yoshiura, Koh-ichiro; Masuzaki, Hideaki
2015-12-01
The aim of this study was to clarify the association between placenta previa and circulating levels of cell-free pregnancy-associated placenta-specific microRNAs (miRNAs) in maternal plasma. Twenty singleton pregnancies with placenta previa (placenta previa group) and 26 uncomplicated pregnancies (control group) were recruited. Blood sampling was performed at 32 weeks of gestation, and cesarean delivery in all cases of placenta previa was performed at a mean gestational age of 37 weeks. The maternal plasma concentrations of cell-free pregnancy-associated placenta-specific miRNAs (miR-517a and miR-518b) were measured by absolute quantitative real-time reverse transcription-polymerase chain reaction. Plasma concentrations of cell-free miR-517a were significantly higher in the placenta previa group than that in the control group (P = .011), while the plasma concentration of cell-free miR-518b was significantly lower in the placenta previa group than that in the control group (P = .004). Plasma concentrations of cell-free miR-517a in placenta previa were significantly higher in placenta previa with alert bleeding later group than those in placenta previa without alert bleeding group or control group (P = .030 or .047, respectively) and correlated with the volume of hemorrhage at delivery (R and P value: .512 and .025). Plasma concentrations of cell-free miR-517a and miR-518b at 32 weeks of gestation were altered in pregnant women with placenta previa, and the circulating level of cell-free miR-517a in placenta previa may be a predictive marker for the risks of alert bleeding later and massive hemorrhage at delivery. © The Author(s) 2015.
Rezeli, Melinda; Végvári, Akos; Ottervald, Jan; Olsson, Tomas; Laurell, Thomas; Marko-Varga, György
2011-12-10
As a proof-of-principle study, a multiple reaction monitoring (MRM) assay was developed for quantitation of proteotypic peptides, representing seven plasma proteins associated with inflammation (complement components and C-reactive protein). The assay development and the sample analysis were performed on a linear ion trap mass spectrometer. We were able to quantify 5 of the 7 target proteins in depleted plasma digests with reasonable reproducibility over a 2 orders of magnitude linear range (RSD≤25%). The assay panel was utilized for the analysis of a small multiple sclerosis sample cohort with 10 diseased and 8 control patients. Copyright © 2011 Elsevier B.V. All rights reserved.
SAMPIE Measurements of the Space Station Plasma Current Analyzed
NASA Technical Reports Server (NTRS)
1996-01-01
In March of 1994, STS-62 carried the NASA Lewis Research Center's Solar Array Module Plasma Interactions Experiment (SAMPIE) into orbit, where it investigated the plasma current collected and the arcs from solar arrays and other space power materials immersed in the low-Earth-orbit space plasma. One of the important experiments conducted was the plasma current collected by a four-cell coupon sample of solar array cells for the international space station. The importance of this experiment dates back to the 1990 and 1991 meetings of the Space Station Electrical Grounding Tiger Team. The Tiger Team determined that unless the electrical potentials on the space station structure were actively controlled via a plasma contactor, the space station structure would arc into the plasma at a rate that would destroy the thermal properties of its surface coatings in only a few years of operation. The space station plasma contactor will control its potentials by emitting electrons into the surrounding low-Earth-orbit plasma at the same rate that they are collected by the solar arrays. Thus, the level at which the space station solar arrays can collect current is very important in verifying that the plasma contactor design can do its job.
Hemodynamic and ADH responses to central blood volume shifts in cardiac-denervated humans
NASA Technical Reports Server (NTRS)
Convertino, V. A.; Thompson, C. A.; Benjamin, B. A.; Keil, L. C.; Savin, W. M.; Gordon, E. P.; Haskell, W. L.; Schroeder, J. S.; Sandler, H.
1990-01-01
Hemodynamic responses and antidiuretic hormone (ADH) were measured during body position changes designed to induce blood volume shifts in ten cardiac transplant recipients to assess the contribution of cardiac and vascular volume receptors in the control of ADH secretion. Each subject underwent 15 min of a control period in the seated posture, then assumed a lying posture for 30 min at 6 deg head down tilt (HDT) followed by 20 min of seated recovery. Venous blood samples and cardiac dimensions (echocardiography) were taken at 0 and 15 min before HDT, 5, 15, and 30 min of HDT, and 5, 15, and 30 min of seated recovery. Blood samples were analyzed for hematocrit, plasma osmolality, plasma renin activity (PRA), and ADH. Resting plasma volume (PV) was measured by Evans blue dye and percent changes in PV during posture changes were calculated from changes in hematocrit. Heart rate (HR) and blood pressure (BP) were recorded every 2 min. Results indicate that cardiac volume receptors are not the only mechanism for the control of ADH release during acute blood volume shifts in man.
Karataylı, Ersin; Altunoğlu, Yasemin Çelik; Karataylı, Senem Ceren; Yurdaydın, Cihan; Bozdayı, A Mithat
2014-10-01
Internal controls (ICs), are the main components of any real-time PCR based amplification methods, which are co-purified and co-amplified with the actual target. The existence of free circulating nucleic acids in plasma and serum (CNAPS) has been known for many years. The aim of this study was to verify whether CNAPS can be used as ICs in real-time PCR based detection and quantification of DNA or RNA targets in plasma and serum samples. Glyceraldehyde-3-phosphate dehydrogenase (GAPDH) as a housekeeping gene, was chosen at random as CNAPS to serve as an intrinsic internal control in two different real-time PCR based quantification models in plasma and serum. Viral loads of hepatitis B virus (HBV) DNA and hepatitis delta virus (HDV) RNA were quantified as actual targets in parallel to GAPDH as IC in a total of 519 serum or plasma samples including 21 healthy controls, 202 positive chronic hepatitis delta patients, 37 chronic hepatitis C patients, 168 chronic hepatitis B patients, 52 patients with hepatocellular carcinoma, and 39 patients with non-alcoholic steatohepatitis/non-alcoholic fatty liver disease. GAPDH levels did not show significant variance in different patient groups and yielded positive signals in all 519 patients with persistent cycle threshold (CT) values 27.85±1.57 (mean±standard deviation (SD)). Reproducibility of the GAPDH amplification in HDV RNA and HBV DNA quantifications was shown with a SD value of CT ranging from 0.42 to 2.14 (mean SD; 1.18) and 0.24 to 1.75 (mean SD; 1.03), respectively. In conclusion, the freely circulating nucleic acids can clearly be used as internal controls for real-time PCR based detection and quantification of any RNA and mainly DNA targets (pathogens) in serum or plasma and this simply excludes the compulsory external addition of any IC molecules into the reaction. Copyright © 2014 Elsevier B.V. All rights reserved.
Biomarkers Associated With the Apolipoprotein E Genotype and Alzheimer Disease
Soares, Holly D.; Potter, William Z.; Pickering, Eve; Kuhn, Max; Immermann, Frederick W.; Shera, David M; Ferm, Mats; Dean, Robert A.; Simon, Adam J.; Swenson, Frank; Siuciak, Judith A.; Kaplow, June; Thambisetty, Madhav; Zagouras, Panayiotis; Koroshetz, Walter J.; Wan, Hong I.; Trojanowski, John Q.; Shaw, Leslie M.
2013-01-01
Background A blood-based test that could be used as a screen for Alzheimer disease (AD) may enable early intervention and better access to treatment. Objective To apply a multiplex immunoassay panel to identify plasma biomarkers of AD using plasma samples from the Alzheimer’s Disease Neuroimaging Initiative cohort. Design Cohort study. Setting The Biomarkers Consortium Alzheimer’s Disease Plasma Proteomics Project. Participants Plasma samples at baseline and at 1 year were analyzed from 396 (345 at 1 year) patients with mild cognitive impairment, 112 (97 at 1 year) patients with AD, and 58 (54 at 1 year) healthy control subjects. Main Outcome Measures Multivariate and univariate statistical analyses were used to examine differences across diagnostic groups and relative to the apolipoprotein E (ApoE) genotype. Results Increased levels of eotaxin 3, pancreatic polypeptide, and N-terminal protein B–type brain natriuretic peptide were observed in patients, confirming similar changes reported in cerebrospinal fluid samples of patients with AD and MCI. Increases in tenascin C levels and decreases in IgM and ApoE levels were also observed. All participants with Apo ε3/ε4 or ε4/ε4 alleles showed a distinct biochemical profile characterized by low C-reactive protein and ApoE levels and by high Cortisol, interleukin 13, apolipoprotein B, and gamma interferon levels. The use of plasma biomarkers improved specificity in differentiating patients with AD from controls, and ApoE plasma levels were lowest in patients whose mild cognitive impairment had progressed to dementia. Conclusions Plasma biomarker results confirm cerebrospinal fluid studies reporting increased levels of pancreatic polypeptide and N-terminal protein B–type brain natriuretic peptide in patients with AD and mild cognitive impairment. Incorporation of plasma biomarkers yielded high sensitivity with improved specificity, supporting their usefulness as a screening tool. The ApoE genotype was associated with a unique biochemical profile irrespective of diagnosis, highlighting the importance of genotype on blood protein profiles. PMID:22801723
Shevchenko, V E; Arnotskaia, N E; Ogorodnikova, E V; Davydov, M M; Ibraev, M A; Turkin, I N; Davydov, M I
2014-01-01
Gastric cancer, one of the most widespread malignant tumors, still lacks reliable serum/plasma biomarkers of its early detection. In this study we have developed, unified, and tested a new methodology for search of gastric cancer biomarkers based on profiling of low molecular weight proteome (LMWP) (1-17 kDa). This approach included three main components: sample pre-fractionation, matrix-assisted laser desorption ionization time of flight mass spectrometry (MALDI-TOF-MS), data analysis by a bioinformatics software package. Applicability and perspectives of the developed approach for detection of potential gastric cancer markers during LMWP analysis have been demonstrated using 69 plasma samples from patients with gastric cancer (stages I-IV) and 238 control samples. The study revealed peptides/polypeptides, which may be potentially used for detection of this pathology.
Lloyd, Amanda J; Beckmann, Manfred; Tailliart, Kathleen; Brown, Wendy Y; Draper, John; Allaway, David
Dog breeds are a consequence of artificial selection for specific attributes. These closed genetic populations have metabolic and physiological characteristics that may be revealed by metabolomic analysis. To identify and characterise the drivers of metabolic differences in the fasted plasma metabolome and then determine metabolites differentiating breeds. Fasted plasma samples were collected from dogs maintained under two environmental conditions (controlled and client-owned at home). The former (n = 33) consisted of three breeds (Labrador Retriever, Cocker Spaniel and Miniature Schnauzer) fed a single diet batch, the latter (n = 96), client-owned dogs consisted of 9 breeds (Beagle, Chihuahua, Cocker Spaniel, Dachshund, Golden Retriever, Greyhound, German Shepherd, Labrador Retriever and Maltese) consuming various diets under differing feeding regimens. Triplicate samples were taken from Beagle (n = 10) and Labrador Retriever (n = 9) over 3 months. Non-targeted metabolite fingerprinting was performed using flow infusion electrospray-ionization mass spectrometry which was coupled with multivariate data analysis. Metadata factors including age, gender, sexual status, weight, diet and breed were investigated. Breed differences were identified in the plasma metabolome of dogs housed in a controlled environment. Triplicate samples from two breeds identified intra-individual variability, yet breed separation was still observed. The main drivers of variance in dogs maintained in the home environment were associated with breed and gender. Furthermore, metabolite signals were identified that discriminated between Labrador Retriever and Cocker Spaniels in both environments. Metabolite fingerprinting of plasma samples can be used to investigate breed differences in client-owned dogs, despite added variance of diet, sexual status and environment.
Further evidence for plasma progranulin as a biomarker in bipolar disorder.
Kittel-Schneider, Sarah; Weigl, Johannes; Volkert, Julia; Geßner, Alexandra; Schmidt, Brigitte; Hempel, Susanne; Kiel, Tilman; Olmes, David G; Bartl, Jasmin; Weber, Heike; Kopf, Juliane; Reif, Andreas
2014-03-01
A recent study suggested that progranulin (encoded by the fronto-temporal dementia risk gene GRN) plasma levels are decreased in bipolar disorder (BD). Replication of this finding is however lacking. Progranulin plasma levels of bipolar patients (n=104) and healthy controls (n=80) were measured by enzyme-linked immunosorbent assay (ELISA). Participants were also genotyped for three single nucleotide polymorphisms (SNPs) in the GRN gene (rs2879096, rs4792938 and rs5848), and the effect of genetic variation on progranulin levels was examined. Plasma progranulin levels were decreased in BD (ANCOVA, p=0.001). Furthermore, age was significantly and positively correlated with plasma progranulin (Pearson׳s correlation, r=0.269, p<0.001). Also, lithium treatment but no other medication had a significant effect on progranulin plasma levels (ANCOVA, p=0.007). Specifically in BD, the GRN SNP rs5848 was associated with progranulin plasma levels (Kruskal-Wallis test, p<0.005). Subgroup analysis regarding bipolar I vs. bipolar II subtype and polarity of the episode at sampling (manic vs. depressed vs. mixed vs. rapid cycling vs. euthymic) could only be performed with limited validity due to the relatively small sample size. The suitability of peripheral progranulin as a biomarker for BD is limited due to the overlap between patients and controls. The findings strengthen the evidence for progranulin being involved in pathomechanisms of bipolar disorder, and suggest a genetic determinant of progranulin concentrations that is relevant specifically in bipolar patients. Copyright © 2014 Elsevier B.V. All rights reserved.
Miyagi, Yohei; Higashiyama, Masahiko; Gochi, Akira; Akaike, Makoto; Ishikawa, Takashi; Miura, Takeshi; Saruki, Nobuhiro; Bando, Etsuro; Kimura, Hideki; Imamura, Fumio; Moriyama, Masatoshi; Ikeda, Ichiro; Chiba, Akihiko; Oshita, Fumihiro; Imaizumi, Akira; Yamamoto, Hiroshi; Miyano, Hiroshi; Horimoto, Katsuhisa; Tochikubo, Osamu; Mitsushima, Toru; Yamakado, Minoru; Okamoto, Naoyuki
2011-01-01
Background Recently, rapid advances have been made in metabolomics-based, easy-to-use early cancer detection methods using blood samples. Among metabolites, profiling of plasma free amino acids (PFAAs) is a promising approach because PFAAs link all organ systems and have important roles in metabolism. Furthermore, PFAA profiles are known to be influenced by specific diseases, including cancers. Therefore, the purpose of the present study was to determine the characteristics of the PFAA profiles in cancer patients and the possibility of using this information for early detection. Methods and Findings Plasma samples were collected from approximately 200 patients from multiple institutes, each diagnosed with one of the following five types of cancer: lung, gastric, colorectal, breast, or prostate cancer. Patients were compared to gender- and age- matched controls also used in this study. The PFAA levels were measured using high-performance liquid chromatography (HPLC)–electrospray ionization (ESI)–mass spectrometry (MS). Univariate analysis revealed significant differences in the PFAA profiles between the controls and the patients with any of the five types of cancer listed above, even those with asymptomatic early-stage disease. Furthermore, multivariate analysis clearly discriminated the cancer patients from the controls in terms of the area under the receiver-operator characteristics curve (AUC of ROC >0.75 for each cancer), regardless of cancer stage. Because this study was designed as case-control study, further investigations, including model construction and validation using cohorts with larger sample sizes, are necessary to determine the usefulness of PFAA profiling. Conclusions These findings suggest that PFAA profiling has great potential for improving cancer screening and diagnosis and understanding disease pathogenesis. PFAA profiles can also be used to determine various disease diagnoses from a single blood sample, which involves a relatively simple plasma assay and imposes a lower physical burden on subjects when compared to existing screening methods. PMID:21915291
NASA Astrophysics Data System (ADS)
Lyon, M.; Rolston, S. L.
2017-01-01
By photoionizing samples of laser-cooled atoms with laser light tuned just above the ionization limit, plasmas can be created with electron and ion temperatures below 10 K. These ultracold neutral plasmas have extended the temperature bounds of plasma physics by two orders of magnitude. Table-top experiments, using many of the tools from atomic physics, allow for the study of plasma phenomena in this new regime with independent control over the density and temperature of the plasma through the excitation process. Characteristic of these systems is an inhomogeneous density profile, inherited from the density distribution of the laser-cooled neutral atom sample. Most work has dealt with unconfined plasmas in vacuum, which expand outward at velocities of order 100 m/s, governed by electron pressure, and with lifetimes of order 100 μs, limited by stray electric fields. Using detection of charged particles and optical detection techniques, a wide variety of properties and phenomena have been observed, including expansion dynamics, collective excitations in both the electrons and ions, and collisional properties. Through three-body recombination collisions, the plasmas rapidly form Rydberg atoms, and clouds of cold Rydberg atoms have been observed to spontaneously avalanche ionize to form plasmas. Of particular interest is the possibility of the formation of strongly coupled plasmas, where Coulomb forces dominate thermal motion and correlations become important. The strongest impediment to strong coupling is disorder-induced heating, a process in which Coulomb energy from an initially disordered sample is converted into thermal energy. This restricts electrons to a weakly coupled regime and leaves the ions barely within the strongly coupled regime. This review will give an overview of the field of ultracold neutral plasmas, from its inception in 1999 to current work, including efforts to increase strong coupling and effects on plasma properties due to strong coupling.
George, Rani; Haywood, Alison; Good, Phillip; Hennig, Stefanie; Khan, Sohil; Norris, Ross; Hardy, Janet
2017-09-01
Methadone is a potent analgesic used to treat refractory cancer pain. It is administered as a racemic mixture, with the l-enantiomer being primarily a μ-receptor agonist, whereas the d-enantiomer is an N-methyl-d-aspartate antagonist and inhibits serotonin and norepinephrine reuptake. Dose requirements vary greatly among patients to achieve optimal pain control and to avoid the risk of adverse effects. The relationship between plasma and saliva methadone enantiomer concentrations was investigated to determine if saliva could be a substitute for plasma in pharmacodynamic and pharmacokinetic studies for clinical monitoring and dose optimization of methadone in patients with advanced cancer. Patients with advanced cancer who were prescribed varying doses of oral methadone for pain management were recruited to obtain paired plasma and saliva samples. Pain scores were recorded at the time of sampling. The total and unbound plasma and saliva concentrations of the l- and d-enantiomers of methadone were quantified by using an HPLC-MS/MS method. The relationship between plasma (total and unbound) and saliva concentrations were compared. The saliva-to-plasma concentration ratio was compared versus the dose administered and the time after dosing for both enantiomers. The association of methadone concentrations with reported pain scores was compared by using a Mann-Whitney U test for significance. Fifty patients receiving a mean dose of 11mg/d of methadone provided 151 paired plasma and saliva samples. The median age of the population was 61 years with an interquartile range of 53-71 years with total body weight ranging from 59-88 kg. Median (interquartile) total plasma concentrations for l- and d-methadone were 50.78 ng/mL (30.6-113.0 ng/mL) and 62.0 ng/mL (28.7-116.0 ng/mL), respectively. Median (interquartile range) saliva concentrations for l- and d-methadone were 81.5 ng/mL (28.0-203.2 ng/mL) and 44.2 (16.2-149.7 ng/mL). No relationship could be established between plasma and saliva concentrations for l- and d-methadone (r 2 = 0.35 and 0.25). The saliva-to-plasma concentration analyzed with the methadone dose showed higher saliva concentrations at lower doses. Dose-normalized saliva concentrations followed a similar pattern over time compared with plasma concentrations. No correlation was found between l-methadone plasma, d-methadone plasma, l-methadone saliva, d-methadone saliva concentrations, and pain score. Saliva concentration was not a better predictor of pain control than plasma concentration for dose optimization and monitoring studies of methadone in patients with cancer. Although the saliva-to-plasma ratio of the concentration of methadone enantiomers was stable across the dosing range, due to the variability in individual saliva-to-plasma ratios, saliva sampling may not be a valid substitute in pharmacokinetic studies of methadone in cancer. Copyright © 2017 Elsevier HS Journals, Inc. All rights reserved.
Nurliyani; Harmayani, Eni; Sunarti
2015-01-01
The study aimed to evaluate the effect of kefir combination from goat milk and soy milk on lipid profile, plasma glucose, glutathione peroxidase (GPx) activity and the improvement of pancreatic β-cell in diabetic rats. Male rats were divided into five treatments: normal control, diabetic control, goat milk kefir, combination of goat milk-soy milk kefir and soy milk kefir. All rats were induced by streptooztocin-nicotinamide (STZ-NA), except for normal control. After 35 d experiment, the rats were sampled for blood, sacrificed and sampled for pancreatic tissues. Results showed that diabetic rats fed kefir combination had higher (p<0.05) triglyceride than the rats fed goat milk or soy milk kefir. Decreasing of plasma glucose in diabetic rats fed kefir combination was higher (p<0.05) than rats fed goat millk kefir. The activity of GPx in diabetic rats fed three kinds of kefir were higher (p<0.01) than untreated diabetic rats. The average number of Langerhans and β-cells in diabetic rats fed kefir combination was the same as the normal control, but it was higher than diabetic control. It was concluded that kefir combination can be used as antidiabetic through maintaining in serum triglyceride, decreasing in plasma glucose, increasing in GPx activity and improving in pancreatic β-cells.
Evaluation of NGAL TestTM on Cobas 6000.
Hansen, Young B L; Damgaard, Anette; Poulsen, Jørgen H
2014-01-01
Neutrophil Gelatinase-Associated Lipocalin (NGAL) is a promising biomarker for acute kidney injury (AKI). Our objectives were to evaluate the NGAL Test(TM) from Bioporto for both urine NGAL and plasma NGAL on the Cobas 6000 c501 (Roche Diagnostics, Rotkreuz, Switzerland) with matched measurements run on Hitachi 917, the method's linearity on the Cobas 6000 in urine, EDTA and Lithium-Heparin (Li-Hep), the influence of using EDTA or Li-Hep tubes and, finally, the impact of freezing and thawing on the sample. Forty matched samples of Li-Hep and EDTA plasma and 40 urine samples were analyzed for method, anticoagulant, and freeze-thaw comparisons. Linearity was assessed using high NGAL samples diluted in urine, EDTA, and Li-Hep plasma. Commercial internal controls were used for the imprecision study. The Cobas 6000 measured identically with the Hitachi 917, however, not in EDTA plasma (Median Difference = 17.50 μg/L, p < 0.0001). Freeze-thaw process reduced NGAL ((EDTA: Mean Difference = = 15.13 μg/L, p = 0.0014)(Li-Hep: Median Difference = = 6.5 μg/L, p = 0.0129)). NGAL results were higher in Li-Hep plasma than in EDTA plasma ((Non-thawed: Median Difference = = 14.5 μg/L, p < 0.0001), (Thawed: Median Difference = = 21.5 μg/L, p = 0.0003)). Linearity agreements were observed in all three specimens. Imprecision (CV%) was below 3%. The NGAL Test(TM) can be applied on the Cobas 6000 with acceptable performance, although the Cobas 6000 measured higher than the Hitachi 917 in EDTA plasma. Though clinically insignificant, we found that the freeze-thaw process had a reduced effect. NGAL results were higher in Li-Hep tubes than in EDTA tubes. Thus, for blood samples we recommend use of EDTA tubes for NGAL measurements.
Okon, M A; Laird, S M; Tuckerman, E M; Li, T C
1998-04-01
To compare plasma androgen concentrations in women who have recurrent miscarriages and in fertile women, and to correlate the results with concentrations of the endometrial protein PP14 in uterine flushings and plasma from women who have recurrent miscarriages. Retrospective study. Hospital research unit. Women attending a recurrent miscarriage clinic and normal fertile volunteers. Ten of the women with recurrent miscarriages had polycystic ovary disease (PCOD) as assessed by ultrasonography or increased follicular LH levels. Plasma samples were obtained from the women on days LH-7, LH-4, LH+0, and LH+7 or LH+10 of a cycle. An endometrial flushing sample and a biopsy specimen were taken from women with recurrent miscarriages on day LH+7 or LH+10. Androstenedione, testosterone, and sex hormone-binding globulin (SHBG) were measured in the plasma samples. The endometrial protein PP14 was measured in the uterine flushings and in the LH+7 or LH+10 plasma samples from the women with recurrent miscarriages. Testosterone concentrations were higher in the women with recurrent miscarriages both with and without PCOD on days LH-7 and LH-4 of the cycle. Concentrations of androstenedione also were higher in the women with recurrent miscarriages, but without PCOD on day LH-7. Testosterone SHBG ratios were higher in the women with recurrent miscarriages, without PCOD compared with the controls on days LH-7, LH+0, and LH+7. Mean follicular testosterone concentrations were correlated negatively with both uterine (r = -0.47) and plasma (r = -0.49) PP14 levels on day LH+10. Mean luteal phase testosterone SHBG ratios were correlated negatively with uterine PP14 concentrations on day LH+7 of the cycle (r = -0.674). Androgen levels are higher in women who have recurrent miscarriages than in normal fertile controls. These high levels of androgens may have a detrimental effect on endometrial function.
Breidinger, S A; Simpson, R C; Mangin, E; Woolf, E J
2015-10-01
A method, using liquid chromatography with tandem mass spectrometric detection (LC-MS/MS), was developed for the determination of suvorexant (MK-4305, Belsomra(®)), a selective dual orexin receptor antagonist for the treatment insomnia, in human plasma over the concentration range of 1-1000ng/mL. Stable isotope labeled (13)C(2)H3-suvorexant was used as an internal standard. The sample preparation procedure utilized liquid-liquid extraction, in the 96-well format, of a 100μL plasma sample with methyl t-butyl ether. The compounds were chromatographed under isocratic conditions on a Waters dC18 (50×2.1mm, 3μm) column with a mobile phase consisting of 30/70 (v/v %) 10mM ammonium formate, pH3/acetonitrile at a flow rate of 0.3mL/min. Multiple reaction monitoring of the precursor-to-product ion pairs for suvorexant (m/z 451→186) and (13)C(2)H3-suvorexant (m/z 455→190) on an Applied Biosystems API 4000 tandem mass spectrometer was used for quantitation. Intraday assay precision, assessed in six different lots of control plasma, was within 10% CV at all concentrations, while assay accuracy ranged from 95.6 to 105.0% of nominal. Quality control (QC) samples in plasma were stored at -20°C. Initial within day analysis of QCs after one freeze-thaw cycle showed accuracy within 9.5% of nominal with precision (CV) of 6.7% or less. The plasma QC samples were demonstrated to be stable for up to 25 months at -20°C. The method described has been used to support clinical studies during Phase I through III of clinical development. Copyright © 2015 Elsevier B.V. All rights reserved.
Ho, Emmie N M; Kwok, W H; Lau, M Y; Wong, April S Y; Lam, Kenneth K H; Stewart, Brian D; Wan, Terence S M
2014-04-18
Granulocyte colony-stimulating factor (G-CSF) is a hematopoietic growth factor regulating granulopoiesis. The recombinant human granulocyte colony-stimulating factor (rhG-CSF) is widely used for the treatment of granulopenia in humans. Filgrastim is a rhG-CSF analogue and is marketed under various brand names, including Neupogen(®) (Amgen), Imumax(®) (Abbott Laboratories), Neukine(®) (Intas Biopharmaceuticals) and others. It is banned in both human and equine sports owing to its potential for misuse. In order to control the abuse of filgrastim in equine sports, a method to identify unequivocally its prior use in horses is required. This study describes an effective screening method for filgrastim in equine plasma by enzyme-linked immunosorbant assays (ELISA), and a follow-up confirmatory method for the unequivocal identification of filgrastim by analysing its highly specific tryptic peptide (1)MTPLGPASSLPQSFLLK(17). Filgrastim was isolated from equine plasma by immunoaffinity purification. After trypsin digestion, the mixture was analysed by nano-liquid chromatography-tandem mass spectrometry (LC/MS/MS). Filgrastim could be detected and confirmed at 0.2ng/mL in equine plasma. The applicability of the ELISA screening method and the LC/MS/MS confirmation method was demonstrated by analysing post-administration plasma samples collected from horses having been co-administered with epoetin alfa as recombinant human erythropoietin (rhEPO) and filgrastim as rhG-CSF. rhEPO and filgrastim could be detected in plasma samples collected from horses for at least 57 and 101h respectively. To our knowledge, this is the first identification of filgrastim in post-administration samples from horses. Copyright © 2014 Elsevier B.V. All rights reserved.
Fitschen-Oestern, Stefanie; Weuster, Matthias; Lippross, Sebastian; Behrendt, Peter; Fuchs, Sabine; Pufe, Thomas; Tohidnezhad, Mersedeh; Bayer, Andreas; Seekamp, Andreas; Varoga, Deike; Klüter, Tim
2017-03-07
Human-beta defensins (HBD) belong to the family of acute phase peptides and hold a broad antimicrobial spectrum that includes gram-positive and gram-negative bacteria. HBD are up-regulated after severe injuries but the source of posttraumatic HBD expression has not been focused on before. In the current study we analysed the role of liver tissue in expression of HBD after multiple trauma in human and mice. HBD-2 expression has been detected in plasma samples of 32 multiple trauma patients (ISS > 16) over 14 days after trauma by ELISA. To investigate major sources of HBD-2, its expression and regulation in plasma samples, polymorphonuclear neutrophils (PMN) and human tissue samples of liver and skin were analysed by ELISA. As liver samples of trauma patients are hard to obtain we tried to review findings in an established trauma model. Plasma samples and liver samples of 56 male C57BL/6 N-mice with a thorax trauma and a femur fracture were analysed by ELISA, real-time PCR and immunohistochemistry for murine beta defensin 4 (MBD-4) and compared with the expression of control group without trauma. The induction of HBD-2 expression in cultured hepatocytes (Hep G2) was analysed after incubation with IL-6, supernatant of Staphylococcus aureus (SA) and Lipopolysaccharides (LPS). One possible signalling pathway was tested by blocking toll-like receptor 2 (TLR2) in hepatocytes. Compared to healthy control group, plasma of multiple traumatized patients and mice showed significantly higher defensin levels after trauma. Compared to skin cells, which are known for high beta defensin expression, liver tissue showed less HBD-2 expression, but higher HBD-2 expression compared to PMN. Immunhistochemical staining demonstrated upregulated MBD-4 in hepatocytes of traumatised mice. In HepG2 cells HBD-2 expression could be increased by stimulation with IL-6 and SA. Neutralization of HepG2 cells with αTLR2 showed reduced HBD-2 expression after stimulation with SA. Plasma samples of multiple traumatized patients showed high expression of HBD-2, which may protect the severely injured patient from overwhelming bacterial infection. Our data support the hypothesis that liver is one possible source for HBD-2 in plasma while posttraumatic inflammatory response.
Quantitative plasma biomarker analysis in HDI exposure assessment.
Flack, Sheila L; Fent, Kenneth W; Trelles Gaines, Linda G; Thomasen, Jennifer M; Whittaker, Steve; Ball, Louise M; Nylander-French, Leena A
2010-01-01
Quantification of amines in biological samples is important for evaluating occupational exposure to diisocyanates. In this study, we describe the quantification of 1,6-hexamethylene diamine (HDA) levels in hydrolyzed plasma of 46 spray painters applying 1,6-hexamethylene diisocyanate (HDI)-containing paint in vehicle repair shops collected during repeated visits to their workplace and their relationship with dermal and inhalation exposure to HDI monomer. HDA was detected in 76% of plasma samples, as heptafluorobutyryl derivatives, and the range of HDA concentrations was < or =0.02-0.92 microg l(-1). After log-transformation of the data, the correlation between plasma HDA levels and HDI inhalation exposure measured on the same workday was low (N = 108, r = 0.22, P = 0.026) compared with the correlation between plasma HDA levels and inhalation exposure occurring approximately 20 to 60 days before blood collection (N = 29, r = 0.57, P = 0.0014). The correlation between plasma HDA levels and HDI dermal exposure measured on the same workday, although statistically significant, was low (N = 108, r = 0.22, P = 0.040) while the correlation between HDA and dermal exposure occurring approximately 20 to 60 days before blood collection was slightly improved (N = 29, r = 0.36, P = 0.053). We evaluated various workplace factors and controls (i.e. location, personal protective equipment use and paint booth type) as modifiers of plasma HDA levels. Workers using a downdraft-ventilated booth had significantly lower plasma HDA levels relative to semi-downdraft and crossdraft booth types (P = 0.0108); this trend was comparable to HDI inhalation and dermal exposure levels stratified by booth type. These findings indicate that HDA concentration in hydrolyzed plasma may be used as a biomarker of cumulative inhalation and dermal exposure to HDI and for investigating the effectiveness of exposure controls in the workplace.
Gauw, R D; Stoffolano, P J; Kuhlenbeck, D L; Patel, V S; Garver, S M; Baker, T R; Wehmeyer, K R
2000-07-21
Semi-automated 96-well plate solid-phase extraction (SPE) was used for sample preparation of fluprostenol, a prostaglandin analog, in rat plasma prior to detection by gas chromatography-negative chemical ionization tandem mass spectrometry (GC-NCI-MS-MS). A liquid handling system was utilized for all aspects of sample handling prior to SPE including transferring of samples into a 96-well format, preparation of standards as well as addition of internal standard to standards, quality control samples and study samples. SPE was performed in a 96-well plate format using octadecylsilane packing and the effluent from the SPE was dried in a custom-made 96-well apparatus. The sample residue was derivatized sequentially with pentafluorobenzylbromide followed by N-methyl-N-trimethylsilyltrifluoroacetamide. The derivatized sample was then analyzed using GC-NCI-MS-MS. The dynamic range for the method was from 7 to 5800 pg/ml with a 0.1-ml plasma sample. The methodology was evaluated over a 4-day period and demonstrated an accuracy of 90-106% with a precision of 2.4-12.9%.
Athanasos, Peter; Ling, Walter; Bochner, Felix; White, Jason M; Somogyi, Andrew A
2018-03-05
Acute pain management in opioid-dependent persons is complicated because of tolerance and opioid-induced hyperalgesia. Very high doses of morphine are ineffective in overcoming opioid-induced hyperalgesia and providing antinociception to methadone-maintained patients in an experimental setting. Whether the same occurs in buprenorphine-maintained subjects is unknown. Randomized double-blind placebo-controlled. Subjects were tested on two occasions, at least five days apart, once with intravenous morphine and once with intravenous saline. Subjects were tested at about the time of putative trough plasma buprenorphine concentrations. Ambulatory. Twelve buprenorphine-maintained subjects: once daily sublingual dose (range = 2-22 mg); no dose change for 1.5-12 months. Ten healthy controls. Intravenous morphine bolus and infusions administered over two hours to achieve two separate pseudo-steady-state plasma concentrations one hour apart. Pain tolerance was assessed by application of nociceptive stimuli (cold pressor [seconds] and electrical stimulation [volts]). Ten blood samples were collected for assay of plasma morphine, buprenorphine, and norbuprenorphine concentrations until three hours after the end of the last infusion; pain tolerance and respiration rate were measured to coincide with blood sampling times. Cold pressor responses (seconds): baseline: control 34 ± 6 vs buprenorphine 17 ± 2 (P = 0.009); morphine infusion-end: control 52 ± 11(P = 0.04), buprenorphine 17 ± 2 (P > 0.5); electrical stimulation responses (volts): baseline: control 65 ± 6 vs buprenorphine 53 ± 5 (P = 0.13); infusion-end: control 74 ± 5 (P = 0.007), buprenorphine 53 ± 5 (P > 0.98). Respiratory rate (breaths per minute): baseline: control 17 vs buprenorphine 14 (P = 0.03); infusion-end: control 15 (P = 0.09), buprenorphine 12 (P < 0.01). Infusion-end plasma morphine concentrations (ng/mL): control 23 ± 1, buprenorphine 136 ± 10. Buprenorphine subjects, compared with controls, were hyperalgesic (cold pressor test), did not experience antinociception, despite high plasma morphine concentrations, and experienced respiratory depression. Clinical implications are discussed.
Naciute, Milda; Mieliauskaite, Diana; Rugiene, Rita; Maciunaite, Gabriele; Mauricas, Mykolas; Murovska, Modra; Girkontaite, Irute
2017-08-01
Parvovirus B19 (B19V) infection is associated with various autoimmune diseases. We investigated the levels of pro-inflammatory (IFNᵧ, TNFα, IL-2, IL-12) and anti-inflammatory (IL-4, IL-10) cytokines in the plasma of B19V DNA positive (B19 + ) and negative (B19 - ) rheumatoid arthritis (RA) patients in comparison with the control group (healthy persons). Blood samples were collected from 118 patients with RA and 49 healthy voluntaries. B19V sequence was determined in whole blood and cell-free plasma DNA by nested PCR. The levels of cytokines in the plasma and cell culture medium from Concanavalin A (ConA) or B19V VP1 protein stimulated PBMC were determined by ELISA. The levels of IL-4, IL-10, IL-12, IL-2 and TNFα were higher in plasma of RA patients in comparison with control persons. B19 + controls and RA patients had lower levels of IFNᵧ in comparison with B19 - controls and RA patients. Within RA patients the plasma levels of IFNᵧ were lower in patients with low RA disease activity or remission. Plasma level of IL-4 was increased and IL-10 level was decreased in B19 + RA patients in comparison with B19 - RA patients and did not differ between B19 + and B19 - controls. B19V infection did not affect plasma levels of IL-12, IL-2, and TNFα. ConA and B19 VP1 protein stimulated PBMC from RA patients produced less IFNᵧ than stimulated PBMC from the healthy controls. B19V infection could differently modulate the amount of cytokines in the plasma of healthy persons and RA patients. Decreased production of IFNᵧ and raised level of plasma IL-4 in RA patients could lower antiviral clearance. Copyright © 2017 Elsevier Ltd. All rights reserved.
Ruiz, P; Basso, N; Grinspon, D; Mangiarua, E; Cannata, M A
1983-01-01
Angiotensinogen is the most important component of the renin-angiotensin system present in the cerebrospinal fluid (CSF) of the rat. Its physiological significance as well as its origin have not been clearly elucidated. In this experiment we have examined plasma renin activity (PRA) and plasma and CSF angiotensinogen concentration under the following experimental conditions in male rats of the Wistar strain: 1) adrenalectomy (Adx) 4 days prior to sample collection; controls were sham Adx animals; 2) nephrectomy (Nx) 48 hours before blood and CSF collection; controls were sham Nx rats; 3) DOC-salt treatment (Cortexon depot, 50 mg/kg.s.c. twice a week) plus saline to drink was given during 4 weeks; controls were intact rats; 4) DOC-salt plus captopril: captopril (100 mg/kg/day) in the drinking fluid was added to the treatment of experimental and control animals of Group 3; 5) two-kidney, two clip hypertension: silver clips placed in both renal arteries 8 weeks before samples collection; control: sham-operated rats; 6) water deprivation: rats deprived of water for 5 days; controls: intact rats; 7) peripheral sympathectomy: 6-hydroxydopamine (6-HODA) injected s.c. from birth until 16 weeks of age, adrenodemedullectomy and adrenal denervation performed at 8 weeks; controls were vehicle-injected animals. Determination of angiotensinogen concentration in plasma and CSF was accomplished by incubation of the samples with excess hog renin. The angiotensin I released as well as PRA were evaluated using an specific radioimmunoassay technique. PRA was significantly increased by Adx, captopril treatment, and water deprivation, and was almost suppressed by Nx, DOC-salt, and DOC-salt plus captopril treatment.(ABSTRACT TRUNCATED AT 250 WORDS)
Plasma Nervonic Acid Is a Potential Biomarker for Major Depressive Disorder: A Pilot Study.
Kageyama, Yuki; Kasahara, Takaoki; Nakamura, Takemichi; Hattori, Kotaro; Deguchi, Yasuhiko; Tani, Munehide; Kuroda, Kenji; Yoshida, Sumiko; Goto, Yu-Ichi; Inoue, Koki; Kato, Tadafumi
2018-03-01
Diagnostic biomarkers of major depressive disorder, bipolar disorder, and schizophrenia are urgently needed, because none are currently available. We performed a comprehensive metabolome analysis of plasma samples from drug-free patients with major depressive disorder (n=9), bipolar disorder (n=6), schizophrenia (n=17), and matched healthy controls (n=19) (cohort 1) using liquid chromatography time-of-flight mass spectrometry. A significant effect of diagnosis was found for 2 metabolites: nervonic acid and cortisone, with nervonic acid being the most significantly altered. The reproducibility of the results and effects of psychotropic medication on nervonic acid were verified in cohort 2, an independent sample set of medicated patients [major depressive disorder (n=45), bipolar disorder (n=71), schizophrenia (n=115)], and controls (n=90) using gas chromatography time-of-flight mass spectrometry. The increased levels of nervonic acid in patients with major depressive disorder compared with controls and patients with bipolar disorder in cohort 1 were replicated in the independent sample set (cohort 2). In cohort 2, plasma nervonic acid levels were also increased in the patients with major depressive disorder compared with the patients with schizophrenia. In cohort 2, nervonic acid levels were increased in the depressive state in patients with major depressive disorder compared with the levels in the remission state in patients with major depressive disorder and the depressive state in patients with bipolar disorder. These results suggested that plasma nervonic acid is a good candidate biomarker for the depressive state of major depressive disorder. © The Author 2017. Published by Oxford University Press on behalf of CINP.
Rechtin, Jack; Torresani, Elisa; Ivanov, Eugene; Olevsky, Eugene
2018-01-01
Spark Plasma Sintering (SPS) is used to fabricate Titanium-Niobium-Zirconium-Tantalum alloy (TNZT) powder—based bioimplant components with controllable porosity. The developed densification maps show the effects of final SPS temperature, pressure, holding time, and initial particle size on final sample relative density. Correlations between the final sample density and mechanical properties of the fabricated TNZT components are also investigated and microstructural analysis of the processed material is conducted. A densification model is proposed and used to calculate the TNZT alloy creep activation energy. The obtained experimental data can be utilized for the optimized fabrication of TNZT components with specific microstructural and mechanical properties suitable for biomedical applications. PMID:29364165
Barton, Ann Kristin; Heinemann, Henrike; Schenk, Ina; Machnik, Marc; Gehlen, Heidrun
2017-02-01
OBJECTIVE To evaluate the influence of respiratory tract disease (ie, recurrent airway obstruction [RAO]) and mode of inhalation on detectability of inhaled budesonide in equine plasma and urine samples. ANIMALS 16 horses (8 healthy control horses and 8 horses affected by RAO, as determined by results of clinical examination, blood gas analysis, bronchoscopy, and cytologic examination of bronchoalveolar lavage fluid). PROCEDURES 4 horses of each group inhaled budesonide (3 μg/kg) twice daily for 10 days while at rest, and the remaining 4 horses of each group inhaled budesonide during lunging exercise. Plasma and urine samples were obtained 4 to 96 hours after inhalation and evaluated for budesonide and, in urine samples, the metabolites 6β-hydroxybudesonide and 16α-hydroxyprednisolone. RESULTS Detected concentrations of budesonide were significantly higher at all time points for RAO-affected horses, compared with concentrations for the control horses. All samples of RAO-affected horses contained budesonide concentrations above the limit of detection at 96 hours after inhalation, whereas this was found for only 2 control horses. Detected concentrations of budesonide were higher, but not significantly so, at all time points in horses that inhaled budesonide during exercise, compared with concentrations for inhalation at rest. CONCLUSIONS AND CLINICAL RELEVANCE Results of this study indicated that the time interval between inhalation of a glucocorticoid and participation in sporting events should be increased when inhalation treatment is administered during exercise to horses affected by respiratory tract disease.
Decreased maternal plasma apelin concentrations in preeclampsia.
Bortoff, Katherine D; Qiu, Chunfang; Runyon, Scott; Williams, Michelle A; Maitra, Rangan
2012-01-01
Preeclampsia is a hypertensive disorder that complicates 3-7% of pregnancies. The development of preeclampsia has not been completely elucidated and current therapies are not broadly efficacious. The apelinergic system appears to be involved in hypertensive disorders and experimental studies indicate a role of this system in preeclampsia. Thus, an epidemiological evaluation of apelin protein concentration in plasma was conducted in case-control study of pregnant women. Data and maternal plasma samples were collected from pregnant women with confirmed preeclampsia (n = 76) or normotensive controls (n = 79). Concentrations of apelin peptides were blindly measured using enzyme-linked immunosorbent assay. Data were subjected to statistical analyses. Plasma apelin concentrations, measured at delivery, were lower in preeclampsia cases compared with controls (mean ± standard deviation: 0.66 ± 0.29 vs. 0.78 ± 0.31 ng/mL, p = 0.02). After controlling for confounding by maternal age, smoking status, and pre-pregnancy body mass index, odds of preeclampsia were 48% lower for women with high versus low plasma apelin (≥0.73 vs. <0.73 ng/mL) concentrations. Reduced circulating apelin peptides may be associated with preeclampsia. The apelinergic system should be further investigated to elucidate its role in preclampsia and other hypertensive maternal disorders.
Mercury (Hg) emissions from coal utilities are difficult to control. Hg eludes capture by most air pollution control devices (APCDs). To determine the gaseous Hg species in stack gases, U.S. EPA Method 5 type sampling is used. In this type of sampling a hole is drilled into th...
Hedaya, Mohsen A; Thomas, Vidhya; Abdel-Hamid, Mohamed E; Kehinde, Elijah O; Phillips, Oludotun A
2017-01-01
Linezolid is the first approved oxazolidinone antibacterial agent, whereas PH027 is a novel compound of the same class that exhibits good in vitro antibacterial activity. The objective of this study was to develop an UPLC-MS/MS assay for the analysis of linezolid and PH027 in plasma and to apply the method for comparative pharmacokinetic and tissue distribution studies of both compounds. Plasma samples and calibrators were extracted with diethyl ether after addition of the internal standard solution. After evaporation of the ether layer, the residue was reconstituted in mobile phase and injected into UPLC-MS/MS. The mobile phase consisted of 2mM ammonium acetate buffer solution and acetonitrile (70:30) at a flow rate of 0.2ml/min. Separation was achieved using UPLC BEH C 18 column, and quantitative determination of the analytes was performed using multiple-reaction monitoring (MRM) scanning mode. The method was validated by analyzing quality control tissue homogenate samples, and was applied to analyze tissue homogenate samples obtained following IV injections of linezolid and PH027 in rabbits. The developed UPLC-MS/MS method was linear in the concentration range of 50-5000ng/ml. Validation of the method proved that the method's precision, selectivity and stability were all within the acceptable limits. Linezolid and PH027 concentrations were accurately determined in the quality control tissue homogenate samples, and analysis of samples obtained following IV administration of the two compounds showed that the tissue to plasma concentration ratio of PH027 was higher than that of linezolid probably due to its higher lipophilicity. The developed UPLC-MS/MS method for the analysis of linezolid and PH027 in rabbit's plasma can accurately determine the concentrations of these compounds in different tissues. Copyright © 2016 Elsevier B.V. All rights reserved.
Limaye, A P; Huang, M L; Leisenring, W; Stensland, L; Corey, L; Boeckh, M
2001-02-01
Among hematopoietic stem-cell transplant (HSCT) recipients, cytomegalovirus (CMV) disease before engraftment is rare but often fatal, and cell-based diagnostic tests have low sensitivity in this clinical setting. We used the quantitative real-time polymerase chain reaction (PCR) assay to test for CMV DNA in plasma samples from 15 HSCT recipients who developed CMV disease before engraftment and from 33 matched control patients. CMV DNA was detected in plasma in 14 (93.3%) of the 15 patients who had CMV disease before engraftment, compared with 5 (15.2%) of 33 control patients (P<.001). CMV DNA was detected a median of 13 days before the onset of CMV disease (range, 0-35 days). The maximum CMV virus load in plasma was >1 log(10) higher among case patients than among control patients (median, 1700 [range, 50 to 5.5x107] vs. <50 [range, <50-350] CMV DNA copies/mL plasma, respectively; P<.001). Quantitative PCR for CMV DNA in plasma appears to be useful for the identification of HSCT recipients at risk for CMV disease before engraftment.
Arsova-Sarafinovska, Zorica; Eken, Ayse; Matevska, Nadica; Erdem, Onur; Sayal, Ahmet; Savaser, Ayhan; Banev, Saso; Petrovski, Daniel; Dzikova, Sonja; Georgiev, Vladimir; Sikole, Aleksandar; Ozgök, Yaşar; Suturkova, Ljubica; Dimovski, Aleksandar J; Aydin, Ahmet
2009-08-01
The study was aimed to evaluate the oxidative/nitrosative stress status in prostate cancer (CaP) and benign prostatic hyperplasia (BPH). 312 men from two different populations were included: 163 men from Macedonia (73 CaP patients, 67 BPH patients and 23 control subjects) and 149 men from Turkey (34 prostate cancer patients, 100 BPH patients and 15 control subjects). We measured erythrocyte malondialdehyde (MDA) levels, erythrocyte activities of superoxide dismutase (CuZn-SOD), glutathione peroxidase (GPX) and catalase (CAT); plasma nitrite/nitrate (NO(2)(-)/NO(3)(-)), cGMP and 8-hydroxy-2'-deoxyguanosine (8-OHdG) levels. A similar pattern of alteration in the oxidative/nitrosative stress-related parameters was found in both, Macedonian and Turkish studied samples: higher MDA concentrations with lower GPX and CuZn-SOD activities in CaP patients versus controls and BPH groups. The CAT activity was decreased in the CaP patients versus controls in the Turkish studied sample. Furthermore, CaP patients had increased plasma NO(2)(-)/NO(3)(-) and cGMP levels versus controls and BPH groups in both studied samples. This study has confirmed an imbalance in the oxidative stress/antioxidant status and revealed an altered nitrosative status in prostate cancer patients.
Wang, Yuan; Zhang, Haiyin; Li, Ying; Wang, Zhen; Fan, Qing; Yu, Shunying; Lin, Zhiguang; Xiao, Zeping
2015-11-01
Anxiety disorders are a category of mental disorders characterized by feelings of anxiety and fear, which include generalized anxiety disorder (GAD). Obsessive-Compulsive Disorder (OCD) used to be categorized as anxiety disorder in DSM-IV. However OCD was no longer included in anxiety disorders and came into its own category titled as Obsessive-Compulsive and Related Disorders (OCRD) in DSM-5. It will be interesting to explore is there any different biological characteristics between OCD and anxiety disorders. Brain-derived neurotrophic factor (BDNF) was a potential candidate gene in both OCD and GAD. The results of genetic association studies between BDNF and OCD have been inconsistent. BDNF plasma/serum levels in OCD have been found lower than those in healthy controls. However the heritable reason of the lowered BDNF levels was not well elucidated. The amount of studies about BDNF and GAD were relatively small. The aims of this study were to determine whether single nucleotide polymorphism Val66Met of BDNF was associated with OCD and GAD, to examine BDNF plasma levels in OCD and GAD, and to explore whether Val66Met variation influences BDNF plasma levels. We genotyped Val66Met variation in 148 OCD patients, 108 GAD patients and 99 healthy controls. Within the same sample, BDNF plasma levels were determined in 113 OCD patients, 102 GAD patients and 63 healthy controls. Val66Met variation was not associated with OCD or GAD. BDNF plasma levels in OCD and GAD patients were significant lower than those in healthy controls. Val66Met variation had no influence on BDNF plasma levels. No difference was found between OCD and GAD. Results do not change no matter taking OCD and GAD as one group or separated two. First, the sample size for genotyping was relatively small, which leaded to a low statistical power of the genetic part in this study. Second, we genotyped just one SNP in BDNF gene. Third, parts of the participants did not be assayed for BDNF plasma levels. Our findings support the hypothesis that BDNF is involved in the pathophysiology of mental disorders, not only OCD but also GAD. OCD and GAD patients both show lower BDNF plasma levels compared to healthy controls. The BDNF plasma levels are not associated with Val66Met variation. Copyright © 2015 Elsevier B.V. All rights reserved.
High Power Helicon Plasma Source for Plasma Processing
NASA Astrophysics Data System (ADS)
Prager, James; Ziemba, Timothy; Miller, Kenneth E.
2015-09-01
Eagle Harbor Technologies (EHT), Inc. is developing a high power helicon plasma source. The high power nature and pulsed neutral gas make this source unique compared to traditional helicon source. These properties produce a plasma flow along the magnetic field lines, and therefore allow the source to be decoupled from the reaction chamber. Neutral gas can be injected downstream, which allows for precision control of the ion-neutral ratio at the surface of the sample. Although operated at high power, the source has demonstrated very low impurity production. This source has applications to nanoparticle productions, surface modification, and ionized physical vapor deposition.
Experimental measurement of the plasma conductivity of Z93 and Z93P thermal control paint
NASA Technical Reports Server (NTRS)
Hillard, G. Barry
1993-01-01
Two samples each of Z93 and Z93P thermal control paint were exposed to a simulated space environment in a plasma chamber. The samples were biased through a series of voltages ranging from -200 volts to +300 volts and electron and ion currents measured. By comparing the currents to those of pure metal samples of the same size and shape, the conductivity of the samples was calculated. Measured conductivity was dependent on the bias potential in all cases. For Z93P, conductivity was approximately constant over much of the bias range and we find a value of 0.5 micro-mhos per square meter for both electron and ion current. For Z93, the dependence on bias was much more pronounced but conductivity can be said to be approximately one order of magnitude larger. In addition to presenting these results, this report documents all of the experimental data as well as the statistical analyses performed.
Glucose tolerance in two unacculturated Indian tribes of Brazil.
Spielman, R S; Fajans, S S; Neel, J V; Pek, S; Floyd, J C; Oliver, W J
1982-08-01
Plasma levels of glucose, insulin, growth hormone, and pancreatic polypeptide in response to a standard oral glucose load were studied in the Yanomama and the Marubo, two relatively unacculturated Amerindian tribes of the Brazilian Amazon. The findings in the two tribes differed significantly from each other and in the degree of deviation from control subjects. The average responses in both tribes differed significantly from those of age- and sex-matched Caucasoid control subjects studied in Ann Arbor, Michigan; however, of the two tribes, the Marubo, the more acculturated group, resembled the controls more closely. Plasma concentrations of glucose and the hormones at three time points (fasting, 1 h, 2 h) were compared by means of a multivariate analysis. When the Marubo were compared with the control subjects, the only highly significant difference was in the plasma glucose concentrations (all three points were higher in the Marubo); however, the Yanomama differed significantly from the control subjects with respect to all four plasma indicators (p less than 0.05). Unlike the Marubo, the Yanomama showed no significant rise in plasma glucose at 1 h and no decrease at 2 h. Neither tribe exhibited the bimodality of the 2 h glucose value characteristic of acculturated Amerindians, such as the Pima, but the samples studied were small.
Changes in plasma thrombospondin-1 concentrations following acute intracerebral hemorrhage.
Dong, Xiao-Qiao; Yu, Wen-Hua; Zhu, Qiang; Cheng, Zhen-Yu; Chen, Yi-Hua; Lin, Xiao-Feng; Ten, Xian-Lin; Tang, Xiao-Bing; Chen, Juan
2015-10-23
Angiogenesis is a fundamental process for brain development and repair. Thrombospondin-1 is the first identified endogenous angiogenesis inhibitor. Its expression in rat brain is upregulated after intracerebral hemorrhage (ICH). We determined whether plasma thrombospondin-1 concentrations are associated with injury severity and prognosis in ICH patients. This observational, prospective study recruited 110 patients and 110 age- and gender-matched healthy controls. Blood samples were collected from the patients at admission and from the healthy controls at study entry to measure plasma thrombospondin-1 concentrations. The endpoints included 1-week mortality, 6-month mortality, 6-month overall survival and 6-month unfavorable outcome (modified Rankin Scale score >2). Plasma thrombospondin-1 concentrations were markedly higher in patients than in healthy controls. Thrombospondin-1 was an independent predictive factor for all endpoints and plasma thrombospondin-1 concentrations were highly associated with injury severity reflected by hematoma volume and National Institutes of Health Stroke Scale score. Under receiver operating characteristic curves, plasma thrombospondin-1 concentrations had similar predictive values compared with hematoma volume and National Institutes of Health Stroke Scale score. Increased plasma thrombospondin-1 concentrations following ICH are independently associated with injury severity and short-term and long-term clinical outcomes. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Teimouri, M.; Godfrey, A.
2017-07-01
Samples of a model dual-phase system, consisting of copper and AISI-420 martensitic steel have been synthesized using spark plasma sintering, with the objective of developing a microstructural analogue for dual-phase steels, in which the volume fraction and size of each phase can be controlled independently. Microstructural investigation of the samples, including fractography of samples deformed in tension until failure, show that densification is strongly temperature dependent. Samples sintered at temperatures of 900 °C or above at a pressure of 60 MPa show a density of more than 98%. The best mechanical properties, in terms of ultimate tensile strength and ductility is found in samples sintered at a temperature of 1000 °C, where a density of nearly 99% is achieved.
Norambuena, M C; Silva, M; Urra, F; Ulloa-Leal, C; Fernández, A; Adams, G P; Huanca, W; Ratto, M H
2013-05-01
The objectives of the study were to determine the effects of nutritional restriction on ovarian function in llamas. Mature female llamas were assigned randomly to a Control group, fed 100% of maintenance energy requirements (MER) (n=8), or a Restricted group (n=8) fed from 70% to 40% of MER until a body condition score of 2.5 was attained. Blood samples were taken every-other-day to determine plasma concentrations of LH, estradiol, leptin and metabolic markers, and follicular dynamics were monitored daily by ultrasonography for 30 days (Experiment 1). Llamas were then treated with GnRH to compare the ovulatory response and corpus luteus (CL) development between groups (Experiment 2). Blood samples were taken to measure LH, leptin, progesterone and metabolic markers and ovarian structures were assessed as in Experiment 1. Llamas in the Restricted group had lower body mass and body condition scores than those in the Control group (P<0.001). Plasma concentrations of cholesterol, non-esterified fatty acids, triglycerides, and urea were higher in the Restricted group (P<0.05) than in the Control group. The day-to-day diameter profiles of the dominant follicles were smaller (P<0.05) in the Restricted group than in the Control group but plasma estradiol concentration did not differ. The ovulation rate and LH secretion in response to GnRH did not differ. Day-to-day profiles of CL diameter, plasma progesterone and leptin concentrations were smaller (P<0.01) in the Restricted group. In conclusion, nutritional restriction in llamas was associated with suppressed follicle and CL development, and lower plasma concentrations of progesterone and leptin. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Caughman, J. B. O.; Baylor, L. R.; Guillorn, M. A.; Merkulov, V. I.; Lowndes, D. H.; Allard, L. F.
2003-08-01
Vertically aligned carbon nanofibers (VACNFs) have been grown using a low-pressure, plasma-enhanced, chemical vapor deposition process. The nanofibers are grown from a nickel catalyst that can be patterned to form arrays of individual, isolated VACNFs. The fibers are grown at pressures below 100 mTorr, using an inductively coupled plasma source with a radio-frequency bias on the sample substrate to allow for independent control of the ion energies. Plasma conditions are related to growth results by comparing optical emission from the plasma to the physical structure of the nanofibers. We find that the ratio of etching species in the plasma to depositing species is critical to the final shape of the carbon structures that are formed.
Macrophage Migration Inhibitory Factor for the Early Prediction of Infarct Size
Chan, William; White, David A.; Wang, Xin‐Yu; Bai, Ru‐Feng; Liu, Yang; Yu, Hai‐Yi; Zhang, You‐Yi; Fan, Fenling; Schneider, Hans G.; Duffy, Stephen J.; Taylor, Andrew J.; Du, Xiao‐Jun; Gao, Wei; Gao, Xiao‐Ming; Dart, Anthony M.
2013-01-01
Background Early diagnosis and knowledge of infarct size is critical for the management of acute myocardial infarction (MI). We evaluated whether early elevated plasma level of macrophage migration inhibitory factor (MIF) is useful for these purposes in patients with ST‐elevation MI (STEMI). Methods and Results We first studied MIF level in plasma and the myocardium in mice and determined infarct size. MI for 15 or 60 minutes resulted in 2.5‐fold increase over control values in plasma MIF levels while MIF content in the ischemic myocardium reduced by 50% and plasma MIF levels correlated with myocardium‐at‐risk and infarct size at both time‐points (P<0.01). In patients with STEMI, we obtained admission plasma samples and measured MIF, conventional troponins (TnI, TnT), high sensitive TnI (hsTnI), creatine kinase (CK), CK‐MB, and myoglobin. Infarct size was assessed by cardiac magnetic resonance (CMR) imaging. Patients with chronic stable angina and healthy volunteers were studied as controls. Of 374 STEMI patients, 68% had elevated admission MIF levels above the highest value in healthy controls (>41.6 ng/mL), a proportion similar to hsTnI (75%) and TnI (50%), but greater than other biomarkers studied (20% to 31%, all P<0.05 versus MIF). Only admission MIF levels correlated with CMR‐derived infarct size, ventricular volumes and ejection fraction (n=42, r=0.46 to 0.77, all P<0.01) at 3 day and 3 months post‐MI. Conclusion Plasma MIF levels are elevated in a high proportion of STEMI patients at the first obtainable sample and these levels are predictive of final infarct size and the extent of cardiac remodeling. PMID:24096574
Gajjala, Prathibha R; Jankowski, Vera; Heinze, Georg; Bilo, Grzegorz; Zanchetti, Alberto; Noels, Heidi; Liehn, Elisa; Perco, Paul; Schulz, Anna; Delles, Christian; Kork, Felix; Biessen, Erik; Narkiewicz, Krzysztof; Kawecka-Jaszcz, Kalina; Floege, Juergen; Soranna, Davide; Zidek, Walter; Jankowski, Joachim
2017-08-01
Despite advancements in lowering blood pressure, the best approach to lower it remains controversial because of the lack of information on the molecular basis of hypertension. We, therefore, performed plasma proteomics of plasma from patients with hypertension to identify molecular determinants detectable in these subjects but not in controls and vice versa. Plasma samples from hypertensive subjects (cases; n=118) and controls (n=85) from the InGenious HyperCare cohort were used for this study and performed mass spectrometric analysis. Using biostatistical methods, plasma peptides specific for hypertension were identified, and a model was developed using least absolute shrinkage and selection operator logistic regression. The underlying peptides were identified and sequenced off-line using matrix-assisted laser desorption ionization orbitrap mass spectrometry. By comparison of the molecular composition of the plasma samples, 27 molecular determinants were identified differently expressed in cases from controls. Seventy percent of the molecular determinants selected were found to occur less likely in hypertensive patients. In cross-validation, the overall R 2 was 0.434, and the area under the curve was 0.891 with 95% confidence interval 0.8482 to 0.9349, P <0.0001. The mean values of the cross-validated proteomic score of normotensive and hypertensive patients were found to be -2.007±0.3568 and 3.383±0.2643, respectively, P <0.0001. The molecular determinants were successfully identified, and the proteomic model developed shows an excellent discriminatory ability between hypertensives and normotensives. The identified molecular determinants may be the starting point for further studies to clarify the molecular causes of hypertension. © 2017 American Heart Association, Inc.
Biocompatible, smooth, plasma-treated nickel-titanium surface--an adequate platform for cell growth.
Chrzanowski, W; Szade, J; Hart, A D; Knowles, J C; Dalby, M J
2012-02-01
High nickel content is believed to reduce the number of biomedical applications of nickel-titanium alloy due to the reported toxicity of nickel. The reduction in nickel release and minimized exposure of the cell to nickel can optimize the biocompatibility of the alloy and increase its use in the application where its shape memory effects and pseudoelasticity are particularly useful, e.g., spinal implants. Many treatments have been tried to improve the biocompatibility of Ni-Ti, and results suggest that a native, smooth surface could provide sufficient tolerance, biologically. We hypothesized that the native surface of nickel-titanium supports cell differentiation and insures good biocompatibility. Three types of surface modifications were investigated: thermal oxidation, alkali treatment, and plasma sputtering, and compared with smooth, ground surface. Thermal oxidation caused a drop in surface nickel content, while negligible chemistry changes were observed for plasma-modified samples when compared with control ground samples. In contrast, alkali treatment caused significant increase in surface nickel concentration and accelerated nickel release. Nickel release was also accelerated in thermally oxidized samples at 600 °C, while in other samples it remained at low level. Both thermal oxidation and alkali treatment increased the roughness of the surface, but mean roughness R(a) was significantly greater for the alkali-treated ones. Ground and plasma-modified samples had 'smooth' surfaces with R(a)=4 nm. Deformability tests showed that the adhesion of the surface layers on samples oxidized at 600 °C and alkali treatment samples was not sufficient; the layer delaminated upon deformation. It was observed that the cell cytoskeletons on the samples with a high nickel content or release were less developed, suggesting some negative effects of nickel on cell growth. These effects were observed primarily during initial cell contact with the surface. The most favorable cell responses were observed for ground and plasma-sputtered surfaces. These studies indicated that smooth, plasma-modified surfaces provide sufficient properties for cells to grow. © The Author(s), 2011.
A Simple Method to Quantitate IP-10 in Dried Blood and Plasma Spots
Aabye, Martine G.; Eugen-Olsen, Jesper; Werlinrud, Anne Marie; Holm, Line Lindebo; Tuuminen, Tamara; Ravn, Pernille; Ruhwald, Morten
2012-01-01
Background Antigen specific release of IP-10 is an established marker for infection with M.tuberculosis. Compared to IFN-γ, IP-10 is released in 100-fold higher concentrations enabling the development of novel assays for detection. Dried blood spots are a convenient sample for high throughput newborn screening. Aim To develop a robust and sensitive ELISA-based assay for IP-10 detection in plasma, dried blood spots (DBS) and dried plasma spots (DPS); to validate the ELISA in clinically relevant samples; and to assess the performance of the assay for detection of Cytomegalovirus (CMV) and M.tuberculosis specific immune responses. Method We raised mice and rat monoclonal antibodies against human IP-10 and developed an ELISA. The assay was validated and applied to the detection of CMV and M.tuberculosis specific responses in 18 patients with immune reactivity towards M.tuberculosis and 32 healthy controls of which 22 had immune reactivity towards CMV and none towards M.tuberculosis. We compared the performance of this new assay to IFN-γ. Results The ELISA was reliable for IP-10 detection in both plasma and filter paper samples. The linear range of the ELISA was 2.5–600 pg/ml. IFN-γ was not readily detectable in DPS samples. IP-10 was stabile in filter paper samples for at least 4 weeks at 37°C. The correlation between IP-10 detected in plasma, DPS and DBS samples was excellent (r2>0.97). Conclusions This newly developed assay is reliable for IP-10 quantification in plasma, DBS and DPS samples from antigen stimulated and non-stimulated whole blood. The filter paper assays enable easy sample acquisition and transport at ambient temperature e.g. via the postal system. The system can potentially simplify diagnostic assays for M.tuberculosis and CMV infection. PMID:22761744
Relationship between substances in seminal plasma and Acrobeads Test results.
Komori, Kazuhiko; Tsujimura, Akira; Okamoto, Yoshio; Matsuoka, Yasuhiro; Takao, Tetsuya; Miyagawa, Yasushi; Takada, Shingo; Nonomura, Norio; Okuyama, Akihiko
2009-01-01
To asses the effects of seminal plasma on sperm function. Retrospective case-control study. University hospital. One hundred fourteen infertile men. Acrobeads Test scores (0-4) and measurement of interleukin (IL)-6, soluble IL-6 receptor, epidermal growth factor, insulin-like growth factor-I (IGF-I), transforming growth factor-beta I, superoxide dismutase, calcitonin, and macrophage migration inhibitory factor (MIF) levels in seminal plasma. Kruskal-Wallis test to compare the concentrations of substances as a nonparametric test for differences among Acrobeads Test scores and a multivariable logistic regression model to find independent risk factors associated with abnormal Acrobeads Test results. The Acrobeads Test score was 0 for 7 samples, 1 for 20 samples, 2 for 18 samples, 3 for 28 samples, and 4 for 41 samples. Age, abstinence period, and semen parameters, except for sperm motility and percentage of sperm with abnormal morphology, had no effect on the Acrobeads Test results. Concentrations of IGF-I and MIF were significantly higher in patients with abnormal Acrobeads Test results. Multivariate analysis indicated that MIF and IGF-I were significantly associated with abnormal Acrobeads Test results (scores 0 to 1). Although further studies are needed, IGF-I and MIF in seminal plasma may have negative effects on sperm function.
NASA Astrophysics Data System (ADS)
Lo, Li; Shen, Chuan-Chou; Lu, Chia-Jung; Chen, Yi-Chi; Chang, Ching-Chih; Wei, Kuo-Yen; Qu, Dingchuang; Gagan, Michael K.
2014-02-01
We have developed a rapid and precise procedure for measuring multiple elements in foraminifera and corals by inductively coupled plasma sector field mass spectrometry (ICP-SF-MS) with both cold- [800 W radio frequency (RF) power] and hot- (1200 W RF power) plasma techniques. Our quality control program includes careful subsampling protocols, contamination-free workbench spaces, and refined plastic-ware cleaning process. Element/Ca ratios are calculated directly from ion beam intensities of 24Mg, 27Al, 43Ca, 55Mn, 57Fe, 86Sr, and 138Ba, using a standard bracketing method. A routine measurement time is 3-5 min per dissolved sample. The matrix effects of nitric acid, and Ca and Sr levels, are carefully quantified and overcome. There is no significant difference between data determined by cold- and hot-plasma methods, but the techniques have different advantages. The cold-plasma technique offers a more stable plasma condition and better reproducibility for ppm-level elements. Long-term 2-sigma relative standard deviations (2-RSD) for repeat measurements of an in-house coral standard are 0.32% for Mg/Ca and 0.43% for Sr/Ca by cold-plasma ICP-SF-MS, and 0.69% for Mg/Ca and 0.51% for Sr/Ca by hot-plasma ICP-SF-MS. The higher sensitivity and enhanced measurement precision of the hot-plasma procedure yields 2-RSD precision for μmol/mol trace elements of 0.60% (Mg/Ca), 9.9% (Al/Ca), 0.68% (Mn/Ca), 2.7% (Fe/Ca), 0.50% (Sr/Ca), and 0.84% (Ba/Ca) for an in-house foraminiferal standard. Our refined ICP-SF-MS technique, which has the advantages of small sample size (2-4 μg carbonate consumed) and fast sample throughput (5-8 samples/hour), should open the way to the production of high precision and high resolution geochemical records for natural carbonate materials.
NASA Astrophysics Data System (ADS)
Yavuz, Hande; Bai, Jinbo
2018-06-01
This paper deals with the dielectric barrier discharge assisted continuous plasma polypyrrole deposition on CNT-grafted carbon fibers for conductive composite applications. The simultaneous effects of three controllable factors have been studied on the electrical resistivity (ER) of these two material systems based on multivariate experimental design methodology. A posterior probability referring to Benjamini-Hochberg (BH) false discovery rate was explored as multiple testing corrections of the t-test p values. BH significance threshold of 0.05 was produced truly statistically significant coefficients to describe ER of two material systems. A group of plasma modified samples was chosen to be used for composite manufacturing to drive an assessment of interlaminar shear properties under static loading. Transversal and longitudinal electrical resistivity (DC, ω =0) of composite samples were studied to compare both the effects of CNT grafting and plasma modification on ER of resultant composites.
NASA Astrophysics Data System (ADS)
Yavuz, Hande; Bai, Jinbo
2017-09-01
This paper deals with the dielectric barrier discharge assisted continuous plasma polypyrrole deposition on CNT-grafted carbon fibers for conductive composite applications. The simultaneous effects of three controllable factors have been studied on the electrical resistivity (ER) of these two material systems based on multivariate experimental design methodology. A posterior probability referring to Benjamini-Hochberg (BH) false discovery rate was explored as multiple testing corrections of the t-test p values. BH significance threshold of 0.05 was produced truly statistically significant coefficients to describe ER of two material systems. A group of plasma modified samples was chosen to be used for composite manufacturing to drive an assessment of interlaminar shear properties under static loading. Transversal and longitudinal electrical resistivity (DC, ω =0) of composite samples were studied to compare both the effects of CNT grafting and plasma modification on ER of resultant composites.
Königsbrügge, Oliver; Weigel, Günter; Quehenberger, Peter; Pabinger, Ingrid; Ay, Cihan
2018-02-07
The effect of direct oral anticoagulants (DOACs) on turbidimetric measurements of plasma clot formation and susceptibility to fibrinolysis may facilitate a comparison between different classes of anticoagulants in plasma samples. We obtained 424 citrate plasma samples from 226 atrial fibrillation patients on anticoagulation and 24 samples without anticoagulation serving as controls. As comparators, we measured the international normalized ratio (INR) for phenprocoumon samples (N = 166), anti-Xa for low molecular weight heparin (LMWH) samples (N = 42), and DOAC levels with mass spectrometry (dabigatran N = 40, rivaroxaban N = 110, apixaban N = 42). Plasma clot formation and lysis were recorded continuously on a photometer after addition of an activation mix (tissue factor 2 pmol/l and tissue plasminogen activator 333 ng/ml). We used linear regression and ANCOVA for correlation analysis. Clot formation lag phase was prolonged in the presence of anticoagulants in a concentration-dependent manner for DOACs (dabigatran Spearman r = 0.74; rivaroxaban r = 0.78; apixaban r = 0.72, all p < 0.0001), INR dependent for phenprocoumon (r = 0.59, p < 0.0001), anti-Xa level dependent in LMWH samples (r = 0.90, p < 0.0001). Maximum rate of clot formation and peak clot turbidity were reduced in the presence of anticoagulants, but correlated only moderately with the comparator measures of anticoagulation. The clot lysis time was inversely correlated with DOAC concentrations in the presence of recombinant thrombomodulin. A direct ex vivo comparison between the effects of different classes of anticoagulants is possible with turbidimetric measurement of plasma clot formation and lysis. Anticoagulation inhibited clot formation in a plasma concentration manner for DOACs, INR dependent for phenprocoumon, and anti-Xa dependent for LMWH. Susceptibility to fibrinolysis increased with increasing DOAC concentrations.
Effects of prolonged physical exercise and fasting upon plasma testosterone level in rats.
Guezennec, C Y; Ferre, P; Serrurier, B; Merino, D; Pesquies, P C
1982-01-01
Prolonged physical exercise and fasting in male rats were studied to determine the effect of these two treatments on plasma testosterone level. Blood and tissue samples were drawn after 1 h, 3 h, 5 h, and 7 h treadmill running, and after 24 h, 48 h, and 72 h of fasting. Both treatments resulted in a significant fall in plasma testosterone, plasma luteinizing hormone (LH), plasma Insulin (IRI) and in liver and muscle glycogen stores. In the course of these two treatments the injection of a supra maximal dose of Human Chorionic Gonadotropin (HCG) produced a rise in plasma testosterone similar to that in control rats. This indicates that the decrease of plasma LH may be responsible for the decrease in plasma testosterone, which is time-related with the decrease in glycogen stores. The possible metabolic role of the decrease in plasma testosterone is discussed.
Ennis, Kathleen; Lusczek, Elizabeth; Rao, Raghavendra
2017-07-13
Treatment of hypoglycemia in children is currently based on plasma glucose measurements. This approach may not ensure neuroprotection since plasma glucose does not reflect the dynamic state of cerebral energy metabolism. To determine whether cerebral metabolic changes during hypoglycemia could be better characterized using plasma metabolomic analysis, insulin-induced acute hypoglycemia was induced in 4-week-old rats. Brain tissue and concurrent plasma samples were collected from hypoglycemic (N=7) and control (N=7) rats after focused microwave fixation to prevent post-mortem metabolic changes. The concentration of 29 metabolites in brain and 34 metabolites in plasma were determined using 1 H NMR spectroscopy at 700MHz and examined using partial least squares-discriminant analysis. The sensitivity of plasma glucose for detecting cerebral energy failure was assessed by determining its relationship to brain phosphocreatine. The brain and plasma metabolite profiles of the hypoglycemia group were distinct from the control group (brain: R 2 =0.92, Q 2 =0.31; plasma: R 2 =0.95, Q 2 =0.74). Concentration differences in glucose, ketone bodies and amino acids were responsible for the intergroup separation. There was 45% concordance between the brain and plasma metabolite profiles. Brain phosphocreatine correlated with brain glucose (control group: R 2 =0.86; hypoglycemia group: R 2 =0.59; p<0.05), but not with plasma glucose. The results confirm that plasma glucose is an insensitive biomarker of cerebral energy changes during hypoglycemia and suggest that a plasma metabolite profile is superior for monitoring cerebral metabolism. Copyright © 2017 Elsevier B.V. All rights reserved.
Eichhold, Thomas H; McCauley-Myers, David L; Khambe, Deepa A; Thompson, Gary A; Hoke, Steven H
2007-01-17
A method for the simultaneous determination of dextromethorphan (DEX), dextrorphan (DET), and guaifenesin (GG) in human plasma was developed, validated, and applied to determine plasma concentrations of these compounds in samples from six clinical pharmacokinetic (PK) studies. Semi-automated liquid handling systems were used to perform the majority of the sample manipulation including liquid/liquid extraction (LLE) of the analytes from human plasma. Stable-isotope-labeled analogues were utilized as internal standards (ISTDs) for each analyte to facilitate accurate and precise quantification. Extracts were analyzed using gradient liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Use of semi-automated LLE with LC-MS/MS proved to be a very rugged and reliable approach for analysis of more than 6200 clinical study samples. The lower limit of quantification was validated at 0.010, 0.010, and 1.0 ng/mL of plasma for DEX, DET, and GG, respectively. Accuracy and precision of quality control (QC) samples for all three analytes met FDA Guidance criteria of +/-15% for average QC accuracy with coefficients of variation less than 15%. Data from the thorough evaluation of the method during development, validation, and application are presented to characterize selectivity, linearity, over-range sample analysis, accuracy, precision, autosampler carry-over, ruggedness, extraction efficiency, ionization suppression, and stability. Pharmacokinetic data are also provided to illustrate improvements in systemic drug and metabolite concentration-time profiles that were achieved by formulation optimization.
Chadebech, Philippe; Bodivit, Gwellaouen; Razazi, Keyvan; de Vassoigne, Christophe; Pellé, Laurence; Burin-des-Roziers, Nicolas; Bocquet, Thibault; Bierling, Philippe; Djoudi, Rachid; Mekontso-Dessap, Armand; Pirenne, France
2017-08-01
Red blood cell (RBC) storage in blood banks is not exempt from cellular injury. Alterations not observed on RBCs freshly isolated from units can rapidly appear in circulation. The transfusion of old blood units, even if this is a controversial issue, could therefore have adverse effects on the recipient. We wanted to determine the respective effects of storage duration and recipient plasma on RBCs for transfusion into patients with severe sepsis. Eleven stored RBC units were sampled at various time points, approximately Days 3 to 8 (referred to as fresh RBCs) and Days 38 to 42 (old RBCs) and tested in coincubation experiments with plasma obtained from 13 patients with severe sepsis and 17 healthy donors as controls. RBCs were tested after 24 or 48 hours at 37°C for the detection of senescence markers (phosphatidylserine exposure, calcium influx, and reactive oxygen species detection and decrease in size) with or without exposure to plasma. We confirmed that a 42-day refrigerated storage of RBCs alone (without any incubation in plasma) had no significant effect on RBCs and no senescence marker detected. By contrast, ex vivo exposure to plasma samples altered both fresh and old RBCs, with a much larger effect for old RBCs, regardless of the plasma used (sepsis vs. control). We show that the main factor affecting the senescence of RBCs for transfusion into patients with severe sepsis is the age of the stored units rather than the clinical status of the recipient. © 2017 AABB.
Sensitive single-stage PCR using custom-synthesized internal controls.
Zimmermann, K; Rieger, M; Gross, P; Turecek, P L; Schwarz, H P
2000-04-01
A new approach for an internally controlled PCR was developed using a custom-synthesized oligonucleotide as the internal control. Three different PCR setups demonstrated the usefulness of this approach: (i) the addition of the respective internal control to samples containing ssDNA virus Parvo B19; (ii) the co-extraction of plasma samples and the respective internal control for the detection of the ssDNA virus TTV; and (iii) the addition of the respective internal control to a crude lysate of tail pieces for the genotyping of FVIII knockout mice, demonstrating that this approach is also applicable for dsDNA.
[Diagnostic values of salivary versus and plasma microRNA-21 for early esophageal cancer].
Ye, Minhua; Ye, Penghui; Zhang, Weizhu; Rao, Jiaqi; Xie, Zijun
2014-06-01
To evaluate the diagnostic value of salivary and plasma miR-21 in patients with esophageal cancer (EC). Total RNA was extracted from saliva and plasma samples from 50 stage I and 50 stage II patients with EC and 50 healthy controls for measurement of miR-21 levels using qPCR. The diagnostic values of salivary and plasma miR-21 levels were assessed for stage I, stage II, and stage I+II EC. Salivary and plasma miR-21 were significantly higher in the EC patients than in the control group. The diagnostic sensitivities of plasma miR-21 for stage I, stage II, and stage I+II EC were 96%, 64% and 97%, with specificities of 44%, 84%, and 56%, respectively; the sensitivities of salivary miR-21 were 90%, 88%, and 89%, respectively, with the same specificities of 64%. Regardless of EC staging, the expression of plasma miR-21 showed a significant positive correlation with that of salivary miR-21, and their diagnostic values were comparable. Both salivary and plasmatic miR-21 can be sensitive biomarkers for EC, and salivary miR-21 detection has the potential to replace plasma detection for EC diagnosis.
Naeem, Tariq M; Matsuta, Hideyuki; Wagatsuma, Kazuaki
2004-12-01
A novel atomic emission spectrometry comprising laser ablation as a sampling source and hollow cathode plasma for the excitation of ablated sample atoms is proposed. In this arrangement, a conventional Grimm-type discharge lamp is employed, but the polarity of the power supply is reversed so that the cylindrical hollow tube acts as a cathode and the glow discharge plasma is produced within this tube. A laser is irradiated to introduce sample atoms into the discharge plasma. Ablated atoms are excited by collisions with electrons and gas species, and emit characteristic radiation upon de-excitation. The experiments were conducted only in an atmosphere of helium gas so as to avoid a rapid erosion of the cathode hollow tube. Phase-sensitive detection with a lock-in amplifier was utilized to reject the continuous background emission of the plasma gas and emissions of sputtered atoms from the tube material. The unique feature of this technique is that the sampling and excitation processes can be controlled independently. The proposed technique was employed for the determination of Cr, Mn, and Ni in low-alloyed steel samples. The obtained concentrations are in good agreement with the reported values. The relative standard deviation (RSD), a measure of the analytical precision, was estimated to be 2-9% for Cr, 3-4% for Mn, and 4-11% for Ni determination.
Ahn, Yeong Hee; Shin, Park Min; Kim, Yong-Sam; Oh, Na Ree; Ji, Eun Sun; Kim, Kwang Hoe; Lee, Yeon Jung; Kim, Sung Ho; Yoo, Jong Shin
2013-11-07
A lectin-coupled mass spectrometry (MS) approach was employed to quantitatively monitor aberrant protein glycosylation in liver cancer plasma. To do this, we compared the difference in the total protein abundance of a target glycoprotein between hepatocellular carcinoma (HCC) plasmas and hepatitis B virus (HBV) plasmas, as well as the difference in lectin-specific protein glycoform abundance of the target glycoprotein. Capturing the lectin-specific protein glycoforms from a plasma sample was accomplished by using a fucose-specific aleuria aurantia lectin (AAL) immobilized onto magnetic beads via a biotin-streptavidin conjugate. Following tryptic digestion of both the total plasma and its AAL-captured fraction of each HCC and HBV sample, targeted proteomic mass spectrometry was conducted quantitatively by a multiple reaction monitoring (MRM) technique. From the MRM-based analysis of the total plasmas and AAL-captured fractions, differences between HCC and HBV plasma groups in fucosylated glycoform levels of target glycoproteins were confirmed to arise from both the change in the total protein abundance of the target proteins and the change incurred by aberrant fucosylation on target glycoproteins in HCC plasma, even when no significant change occurs in the total protein abundance level. Combining the MRM-based analysis method with the lectin-capturing technique proved to be a successful means of quantitatively investigating aberrant protein glycosylation in cancer plasma samples. Additionally, it was elucidated that the differences between HCC and control groups in fucosylated biomarker candidates A1AT and FETUA mainly originated from an increase in fucosylation levels on these target glycoproteins, rather than an increase in the total protein abundance of the target glycoproteins.
Comparative plasma disposition of fenbendazole, oxfendazole and albendazole in dogs.
Gokbulut, C; Bilgili, A; Hanedan, B; McKellar, Q A
2007-09-30
The plasma disposition of fenbendazole (FBZ), oxfendazole (OFZ) and albendazole (ABZ); and the enantiospecific disposition of OFZ, and ABZSO produced were investigated following an oral administration (50 mg/kg) in dogs. Blood samples were collected from 1 to 120 h post-administration. The plasma samples were analysed by high performance liquid chromatography (HPLC). The plasma concentration of FBZ, OFZ, ABZ and their metabolites were significantly different from each other and depended on the drug administered. The sulphone metabolite (FBZSO2) of FBZ was not detected in any plasma samples and the parent molecule ABZ did not reach quantifiable concentrations following FBZ and ABZ administration, respectively. OFZ and its sulphone metabolite attained a significantly higher plasma concentration and remained much longer in plasma compared with FBZ and ABZ and their respective metabolites. The maximum plasma concentrations (Cmax), area under the concentration time curve (AUC) and mean residence time (MRT) of parent OFZ were more than 30, 68 and 2 times those of FBZ, respectively. The same parameters for ABZSO were also significantly greater than those of FBZSO. The ratio for total AUCs of both the parent drug and the metabolites were 1:42:7 for following FBZ, OFZ and ABZ administration, respectively. The enantiomers were never in racemic proportions and (+) enantiomers of both OFZ and ABZSO were predominant in plasma. The AUC of (+) enantiomers of OFZ and ABZSO was, respectively more than three and seven times larger than that of (-) enantiomers of both molecules. It is concluded that the plasma concentration of OFZ was substantially greater compared with FBZ and ABZ. The data on the pharmacokinetic profile of OFZ presented here may contribute to evaluate its potential as an anthelmintic drug for parasite control in dogs.
NASA Astrophysics Data System (ADS)
Duan, Yixiang; Su, Yongxuan; Jin, Zhe; Abeln, Stephen P.
2000-03-01
The development of a highly sensitive, field portable, low-powered instrument for on-site, real-time liquid waste stream monitoring is described in this article. A series of factors such as system sensitivity and portability, plasma source, sample introduction, desolvation system, power supply, and the instrument configuration, were carefully considered in the design of the portable instrument. A newly designed, miniature, modified microwave plasma source was selected as the emission source for spectroscopy measurement, and an integrated small spectrometer with a charge-coupled device detector was installed for signal processing and detection. An innovative beam collection system with optical fibers was designed and used for emission signal collection. Microwave plasma can be sustained with various gases at relatively low power, and it possesses high detection capabilities for both metal and nonmetal pollutants, making it desirable to use for on-site, real-time, liquid waste stream monitoring. An effective in situ sampling system was coupled with a high efficiency desolvation device for direct-sampling liquid samples into the plasma. A portable computer control system is used for data processing. The new, integrated instrument can be easily used for on-site, real-time monitoring in the field. The system possesses a series of advantages, including high sensitivity for metal and nonmetal elements; in situ sampling; compact structure; low cost; and ease of operation and handling. These advantages will significantly overcome the limitations of previous monitoring techniques and make great contributions to environmental restoration and monitoring.
[Characteristic of sample banks isolated from EDTA-blood by sedimentation method].
Chen, Zhi-bin; Lin, Qin; Ma, Chang-hua; Liu, Kai-ning; Meng, Huan-xin
2014-02-18
To assess the characteristics of establishing the different sample banks of plasma, leukocytes and DNA by sedimentation method of isolating from ethylene diamine tetraacetic acid(EDTA)-blood and to clarify the sedimentation method of leukocyte isolation and plasma volume by comparative data and recommended procedures for applicability. In the study, 29 EDTA-bloods were obtained, the total amounts of leukocytes and the percentage of neutrophile granulocytes, and lymphocytes in the EDTA-blood detected as a control group and then assigned equally into 4 EP tubes with 1 mL EDTA-blood per tube as 4 test groups, then the 4 tubes were placed with the EDTA-blood at room temperature and the plasma layers were isolated at 0.5, 1, 2 and 3 h, receptively. The total amount of leukocytes and the percentage of neutrophile granulocytes, and lymphocytes were detected by automated hematology analyzer at the clinical laboratory. The volume of the plasma was also measured at the same time. The plasma volume at 0.5 h [(241.72 ± 101.52)μL] was substantially lower than those at 1 h[(317.24 ± 97.50)μL], at 2 h[(371.03 ± 91.66)μL], and at 3 h [(408.97 ± 97.43)μL] , P < 0.05. The plasma volume at 1 h was substantially lower than those at 2 h and 3 h (P < 0.05). The total amount of leukocytes in the plasma layer at 0.5 h (2.50 × 10(6) ± 1.48 × 10(6)) group was substantially higher than the amount of 2 or 3 h groups respectively (1.47 × 10(6) ± 7.19 × 105,1.21 × 10(6) ± 7.41 × 105), P < 0.05. Significant difference was not found between 0.5 h group and 1 h group (2.29 × 10(6)± 1.17 × 10(6)), P > 0.05. The total amount of leukocytes in the plasma layer in 1 h group was substantially higher than that in 2 h and 3 h groups (P < 0.05). There was no significant difference between 3 h group and 2 h group (P > 0.05). The total amount of leukocytes in the plasma layer of the 4 test groups was substantially lower than that in the control group (P < 0.05). The percentage of neutrophile granulocytes (54.14% ± 11.65%) in the plasma layer in 0.5 h group was substantially higher than those in 1 h, 2 h and 3 h groups (46.66% ± 12.70%,39.17% ± 12.33%,43.25% ± 14.54%), P < 0.05, respectively, which was the substantially lower than that in the control group (60.53% ± 8.46%), P < 0.05. The average value of the percentage of neutrophile granulocytes in the plasma layer in 1 h group was substantially higher than that in 2 h group (P < 0.05). There was no significant different between 3 h group and both 1 h, 2 h groups (P > 0.05). The mean percentage of lymphocytes in the plasma layer in 0.5 h group (35.09% ± 10.84%) was substantially lower than those in the plasma layer in 1 h, 2 h and 3 h groups, respectively ( 41.48% ± 12.20%, 47.96% ± 12.27%, 45.50% ± 13.71%), which was significant higher than that in the control group(30.98% ± 7.33%), P < 0.05. The average value of the percentage of lymphocytes in the plasma layer in 1 h group was substantially higher than those in the control group and 0.5 h group, but was substantially lower than those in 2 h and 3 h groups (P < 0.05). The average value of percentage of lymphocytes in the plasma layer in 2 h group was substantially higher than those in the control group, 0.5 h and 1 h groups (P < 0.05). There was no significant difference between 2 h and 3 h groups (P > 0.05). The best period of time in obtaining leukocytes is 0.5-1 h sedimentation of EDTA-blood. Both the plasma layer and leukocytes can be separated and obtained at the same time from the same sample by the sedimentation method of EDTA-blood. The sedimentation of EDTA-blood has the least interference of both chemical and physical factors, as well as a ready operation, which can establish the plasma, leukocytes and DNA sample banks for various aspects of research.
Ingale, Yashwant; Routray, Samapika; Kheur, Supriya M; Kheur, Mohit; Mohanty, Neeta
2014-09-01
This study aimed to correlate the prognostic value of osteopontin (OPN) expression using both tissue and plasma samples from patients with clinically and histologically confirmed oral squamous cell carcinoma (OSCC). The study group comprised of sixty patients (n = 60), which were clinically and histologically diagnosed for oral squamous cell carcinoma (OSCC). The Control group comprised of ten (n = 10) healthy volunteers. Plasma OPN levels were assayed using a quantitative enzyme-linked immunosorbent assay (OPN ELISA). Expression of OPN was also identified and evaluated by immunohistochemistry in tissue sections. These OPN expressions were then correlated with different parameters like age, sex, site, clinical presentation, tumor node metastasis (TNM) staging, histopathological grading and lymph node metastasis. One-way analysis of variance (ANOVA) was used to evaluate the difference in tissue intensity and plasma OPN levels between the OSCC and the normal control groups. The distribution of the plasma OPN levels and tissue OPN intensity in OSCC cohorts were compared to histopathological grades and analyzed. When evaluated OPN expression in tissue had higher intensity observed in OSCC (95% +ve) cases. And the mean plasma OPN concentration in OSCC cohort was more in comparison to the normal cohort. The results clearly showed that the plasma OPN levels and intensity grading in tissue correlated with tumor grades. The study highlights OPN as a biomarker for prognosis in OSCC in both plasma and tissue samples. We would like to emphasize on the evaluation of plasma OPN as a protocol of blood examination for all cancer patient, as it may serve as an indicator for tumor progression and potential risk of metastasis.
Plasma levels of hypoxia-regulated factors in patients with age-related macular degeneration.
Ioanna, Zygoula; Christian, Schori; Christian, Grimm; Daniel, Barthelmes
2018-02-01
Various hypoxia-related proteins are differentially expressed in the retina and secreted to the vitreous and/or aqueous humor of patients affected by dry or neovascular age-related macular degeneration (nAMD). To determine whether these conditions alter concentrations of cytokines also in the systemic circulation, we measured plasma levels of six hypoxia-related proteins. Plasma was prepared from EDTA blood that was collected from patients affected by dry AMD (n = 5), nAMD (n = 11), proliferative diabetic retinopathy (PDR; n = 9), and patients with an epiretinal membrane (ERM; n = 11). ERM samples served as negative controls, PDR samples as positive controls. Protein concentrations of vascular endothelial growth factor (VEGF), erythropoietin (EPO), angiopoietin-like 4 (ANGPTL4), placental growth factor (PlGF), tumor necrosis factor alpha (TNF-α), and pigment epithelium-derived factor (PEDF) were determined by enzyme-linked immunosorbent assay (ELISA). The concentration of PlGF was significantly increased in plasma of patients affected by nAMD. Although no statistically significant differences were found for EPO, ANGPTL4, PlGF, TNF-α, and PEDF, the mean concentration of VEGF was lowest in the nAMD group. Plasma concentrations of the six factors did not correlate with gender or age of patients. nAMD may increase plasma concentrations of PlGF, making it a candidate as a biomarker for the neovascular form of AMD. Other factors, however, were not differentially regulated, suggesting that their systemic concentrations are not generally increased in hypoxia-related retinal diseases.
Detection of tetracosactide in plasma by enzyme-linked immunosorbent assay (ELISA).
Martin, Laurent; Chaabo, Ayman; Lasne, Françoise
2015-06-01
As a synthetic analogue of adrenocorticotropic hormone (ACTH), tetracosactide is prohibited in sport by the World Anti-Doping Agency (WADA). An enzyme-linked immunosorbent assay (ELISA) method is proposed for detection of this drug in plasma. Since its structure corresponds to the 24 N-terminal of the 39 amino acids of the natural endogenous peptide ACTH, tetracosactide can be detected with a commercial ELISA kit for ACTH that uses antibodies, the epitopes of which are located in the 1-24 part of ACTH. However, an essential condition for detection specificity is the preliminary total clearance of endogenous ACTH in the plasma samples. This is achieved by a preparative step based on cation-exchange chromatography before ELISA. The method is specific and sensitive (LOD: 30 pg/mL) and may be used as a screening analysis in anti-doping control. The pre-analytical conditions are shown to be of the upmost importance and recommendations for blood collection (EDTA tubes), sample transport (4 °C) and plasma sample storage (-20 °C) are presented. Copyright © 2014 John Wiley & Sons, Ltd.
Plasma-derived microparticles in polycythaemia vera.
Ahadon, M; Abdul Aziz, S; Wong, C L; Leong, C F
2018-04-01
Microparticles are membrane bound vesicles, measuring less than 1.0 um, which are released during cellular activation or during apoptosis. Studies have shown that these circulating microparticles play a role in coagulation, cell signaling and cellular interactions. Increased levels of circulating microparticles have been observed in a number of conditions where there is vascular dysfunction, thrombosis and inflammation. The objective of this study was to determine the various plasma-derived microparticles in patients with polycythaemia vera (PV) in Universiti Kebangsaan Malaysia Medical Centre and to compare them with normal control. A total of 15 patients with PV and 15 healthy volunteers were included in this cross-sectional descriptive study. Plasma samples from both patients and healthy volunteers were prepared and further processed for isolation of microparticles. Flow cytometry analyses were then carried out in all samples to determine the cellular origin of the microparticles. Full blood count parameters for both groups were also collected. Data collected were analyzed using SPSS version 12.0. Patients with PV had a significantly higher percentage of platelet derived microparticles compared to healthy controls (P <0.05). The control group had a higher level of endothelial derived microparticles but the differences were not statistically significant (P > 0.05). The median percentage of positive events for platelet derived microparticles was higher in patients with PV compared to normal healthy controls.
Association of plasma arginine with breast cancer molecular subtypes in women of Liaoning province.
Hu, Lu; Gao, Yu; Cao, Yunfeng; Zhang, Yinxu; Xu, Minghao; Wang, Yuanyuan; Jing, Yu; Guo, Shengnan; Jing, Fangyu; Hu, Xiaodan; Zhu, Zhitu
2016-12-01
Arginine is one of the human nonessential amino acids critical for the growth of human cancers. The aim of this study is to investigate the variation of arginine between breast cancer (BC) patients and benign mammary gland disease (control) patients to determine its value in predicting the risk of BC. We also explore the associations between arginine levels and breast cancer subtypes. Preoperative blood samples were obtained from 267 patients (102 BC and 165 controls) in 2015. Plasma arginine values were determined for all preoperative blood samples using liquid chromatography-tandem mass spectrometry (LC-MS/MS) to analyse differences in arginine levels between BC patients and control patients and the correlations between arginine and clinicopathologic parameters in BC. The arginine levels of BC patients were significantly lower than those of control patients (5.96 [3.76-12.47] vs. 12.54 [7.14-24.94], P = 0.000). The area under the curve (AUC) for arginine was 0.721 (95% CI, 0.660-0.782, P < 0.0001). The concentration of arginine was significantly different among different molecular BC subtypes (P = 0.030). Our results suggested that plasma arginine was associated with breast cancer molecular subtypes. © 2016 IUBMB Life, 68(12):980-984, 2016. © 2016 International Union of Biochemistry and Molecular Biology.
Nait Mouloud, M; Ouennoughi, F; Yaiche, L; Kaidi, R; Iguer-Ouada, M
2017-03-15
The aim of this study was to assess the effects of female bovine plasma collected at different days of the reproductive cycle on epididymal spermatozoa motility and to test hypothesis that the subpopulations pattern of motile spermatozoa is affected by this treatment. Blood plasma samples were collected from five Holstein Friesian cows at different stages of the estrous cycle (days 0, 5, 10, 12 and 18), one pregnant cow and one adult bull and were diluted 1:9 (V/V) with normal saline. Female charcoal-treated plasma, Bull plasma and saline were used as controls. Semen samples were obtained from cauda epididymidis through retrograde flushing and diluted in saline to approximately 60 × 106 sperm/ml. The extended semen was diluted 1:2 (V/V) with tested media and motility was evaluated at 15 min and then every hour for 6 h using a computer-assisted semen analysis. Multivariate clustering procedure was applied to identify and quantify specific subpopulations within the semen samples. The statistical analysis clustered all the motile spermatozoa into three separate subpopulations with defined patterns of movement: Subpopulation 1 poorly motile and non-progressive spermatozoa (39.3%), subpopulation 2 including the fastest and the most vigorous spermatozoa (46.4%) and subpopulation 3 represented by slow, non-vigorous but linear spermatozoa (14.3%). Initially, sperm samples supplemented with female, male or female charcoal-treated plasma stimulated equally total motility and spermatozoa belonging to subpopulation 2 regardless of the estrous cycle stage. After 1-h incubation, the motility of these both categories of spermatozoa (total motile and those assigned to subpopulation 2) is enhanced and maintained more in day 12, 18 and pregnant cow plasma than in female plasma from earlier stage of the estrous cycle (day 0, 5 and 10), male plasma and female-charcoal treated plasma. In conclusion, the overall results showed that female plasma stimulated significantly sperm motility, especially at the late stage of the estrous cycle. Additionally, to the diverse compounds contained in blood plasma, progesterone may play a key role in such motility activation. Copyright © 2016 Elsevier Inc. All rights reserved.
Controlled alignment of carbon nanofibers in a large-scale synthesis process
NASA Astrophysics Data System (ADS)
Merkulov, Vladimir I.; Melechko, A. V.; Guillorn, M. A.; Simpson, M. L.; Lowndes, D. H.; Whealton, J. H.; Raridon, R. J.
2002-06-01
Controlled alignment of catalytically grown carbon nanofibers (CNFs) at a variable angle to the substrate during a plasma-enhanced chemical vapor deposition process is achieved. The CNF alignment is controlled by the direction of the electric field lines during the synthesis process. Off normal CNF orientations are achieved by positioning the sample in the vicinity of geometrical features of the sample holder, where bending of the electric field lines occurs. The controlled growth of kinked CNFs that consist of two parts aligned at different angles to the substrate normal also is demonstrated.
Zhong, Xiao Yan; Holzgreve, Wolfgang; Gebhardt, Stefan; Hillermann, Renate; Tofa, Kashefa Carelse; Gupta, Anurag Kumar; Huppertz, Berthold; Hahn, Sinuhe
2006-01-01
We have recently observed that fetal DNA and fetal corticotropin-releasing hormone (CRH) mRNA are associated with in vitro generated syncytiotrophoblast-derived microparticles, and that the ratio of fetal DNA to mRNA (CRH) varied according to whether the particles were derived by predominantly apoptotic, apo-necrotic or necrotic pathways. Hence, we examined whether these ratios varied in maternal plasma samples taken from normotensive and preeclamptic pregnancies in vivo. Maternal plasma samples were collected from 18 cases with preeclampsia and 29 normotensive term controls. Circulatory fetal CRH mRNA and DNA levels were quantified by real-time PCR and RT-PCR. Circulatory fetal mRNA and fetal DNA levels were significantly elevated in the preeclampsia study group when compared to normotensive controls. Alterations in the fetal mRNA to DNA ratio between the study and control groups were minimal, even when stratified into early (<34 weeks of gestation) and late (>34 weeks of gestation) onset preeclampsia. Our data suggest that although circulatory fetal DNA and mRNA levels are significantly elevated in preeclampsia, the ratios in maternal plasma are not dramatically altered. Copyright 2006 S. Karger AG, Basel.
Plasma homovanillic acid in the prodromal phase of schizophrenia.
Sumiyoshi, T; Kurachi, M; Kurokawa, K; Yotsutsuji, T; Uehara, T; Itoh, H; Saitoh, O
2000-03-01
Plasma levels of homovanillic acid (pHVA) have been used as a peripheral measure of central dopaminergic activity. Despite a large body of studies investigating pHVA in schizophrenia, little is known about pHVA in patients in the prodromal phase of the illness. Plasma HVA levels of 12 male outpatients meeting DSM-III-R criteria for the prodromal phase of schizophrenia at the time of blood sampling (who later developed psychotic symptoms) were compared with those of 12 normal male healthy volunteers. Task amounts in the Kraepelin arithmetic test at the time of blood sampling were compared between the prodromal patients and normal controls and were correlated with pHVA levels. The prodromal patients had significantly higher pHVA levels compared with normal control subjects. The mean amount of the arithmetic task for the prodromal patients was significantly less than that for controls. In the patient group, a significant negative correlation was observed between pHVA levels and the task amounts. Data from the present study indicate the presence of dopaminergic dysfunction in the prodromal stage of schizophrenia that is associated with neuropsychological impairment. Increased pHVA levels in the prodromal patients may have implications for early detection of schizophrenia.
Li, Yuan-yuan; Xiao, Rui; Li, Cai-ping; Huangfu, Jian; Mao, Jiang-feng
2015-02-08
The aim of this study was to investigate the relationship between plasma fatty acid binding protein 4 (FABP4), phosphatase and tensin homolog (PTEN), and insulin resistance in patients with gestational diabetes mellitus (GDM). Plasma FABP4 and PTEN were determined by ELISA in GDM patients (GDM group, n=30) and in euglycemic pregnant women (control group, n=30). The clinical features, body mass index (BMI), homeostasis model assessment of insulin resistance (HOMA-IR), and lipid profiles were compared between the 2 groups. The influence of risk factors on insulin resistance, including BMI, lipid profiles, FABP4, and PTEN, were further investigated by multiple-factor stepwise regression analysis. Higher levels of BMI, ΔBMI, triglyceride (TG), fasting plasma glucose (FPG), 2-hour plasma glucose (2hPG), fasting insulin, HOMA-IR, FABP4, PTEN, and lower level of high-density lipoprotein cholesterol (HDL-C) were found in the GDM patients than in the controls (all P<0.005). The plasma FABP4 was 1.47±0.25 vs. 0.20±0.07 ng/ml in the GDM and control group, respectively (P<0.0001). Plasma PTEN was 6.46±1.57 vs. 4.72±0.82 ng/ml in the GDM and control group, respectively (P<0.0001). There was a positive relation between plasma FABP4 and PTEN when all blood samples, including GDM and control groups, were analyzed (P<0.05). The multiple-factor regression analysis revealed that plasma FABP4, TG, and PTEN were independent risk factors for increased insulin resistance. GDM patients have more severe insulin resistance compared to euglycemic pregnant women. Higher levels of plasma FABP4 and PTEN are associated with increased insulin resistance and may participate in the pathogenesis of insulin resistance during gestation.
Drosten, C.; Seifried, E.; Roth, W. K.
2001-01-01
Screening of blood donors for human immunodeficiency virus type 1 (HIV-1) infection by PCR permits the earlier diagnosis of HIV-1 infection compared with that by serologic assays. We have established a high-throughput reverse transcription (RT)-PCR assay based on 5′-nuclease PCR. By in-tube detection of HIV-1 RNA with a fluorogenic probe, the 5′-nuclease PCR technology (TaqMan PCR) eliminates the risk of carryover contamination, a major problem in PCR testing. We outline the development and evaluation of the PCR assay from a technical point of view. A one-step RT-PCR that targets the gag genes of all known HIV-1 group M isolates was developed. An internal control RNA detectable with a heterologous 5′-nuclease probe was derived from the viral target cDNA and was packaged into MS2 coliphages (Armored RNA). Because the RNA was protected against digestion with RNase, it could be spiked into patient plasma to control the complete sample preparation and amplification process. The assay detected 831 HIV-1 type B genome equivalents per ml of native plasma (95% confidence interval [CI], 759 to 936 HIV-1 B genome equivalents per ml) with a ≥95% probability of a positive result, as determined by probit regression analysis. A detection limit of 1,195 genome equivalents per ml of (individual) donor plasma (95% CI, 1,014 to 1,470 genome equivalents per ml of plasma pooled from individuals) was achieved when 96 samples were pooled and enriched by centrifugation. Up to 4,000 plasma samples per PCR run were tested in a 3-month trial period. Although data from the present pilot feasibility study will have to be complemented by a large clinical validation study, the assay is a promising approach to the high-throughput screening of blood donors and is the first noncommercial test for high-throughput screening for HIV-1. PMID:11724836
Harmayani, Eni; Sunarti
2015-01-01
The study aimed to evaluate the effect of kefir combination from goat milk and soy milk on lipid profile, plasma glucose, glutathione peroxidase (GPx) activity and the improvement of pancreatic β-cell in diabetic rats. Male rats were divided into five treatments: normal control, diabetic control, goat milk kefir, combination of goat milk-soy milk kefir and soy milk kefir. All rats were induced by streptooztocin-nicotinamide (STZ-NA), except for normal control. After 35 d experiment, the rats were sampled for blood, sacrificed and sampled for pancreatic tissues. Results showed that diabetic rats fed kefir combination had higher (p<0.05) triglyceride than the rats fed goat milk or soy milk kefir. Decreasing of plasma glucose in diabetic rats fed kefir combination was higher (p<0.05) than rats fed goat millk kefir. The activity of GPx in diabetic rats fed three kinds of kefir were higher (p<0.01) than untreated diabetic rats. The average number of Langerhans and β-cells in diabetic rats fed kefir combination was the same as the normal control, but it was higher than diabetic control. It was concluded that kefir combination can be used as antidiabetic through maintaining in serum triglyceride, decreasing in plasma glucose, increasing in GPx activity and improving in pancreatic β-cells. PMID:26877646
Lan, Jiayi; Núñez Galindo, Antonio; Doecke, James; Fowler, Christopher; Martins, Ralph N; Rainey-Smith, Stephanie R; Cominetti, Ornella; Dayon, Loïc
2018-04-06
Over the last two decades, EDTA-plasma has been used as the preferred sample matrix for human blood proteomic profiling. Serum has also been employed widely. Only a few studies have assessed the difference and relevance of the proteome profiles obtained from plasma samples, such as EDTA-plasma or lithium-heparin-plasma, and serum. A more complete evaluation of the use of EDTA-plasma, heparin-plasma, and serum would greatly expand the comprehensiveness of shotgun proteomics of blood samples. In this study, we evaluated the use of heparin-plasma with respect to EDTA-plasma and serum to profile blood proteomes using a scalable automated proteomic pipeline (ASAP 2 ). The use of plasma and serum for mass-spectrometry-based shotgun proteomics was first tested with commercial pooled samples. The proteome coverage consistency and the quantitative performance were compared. Furthermore, protein measurements in EDTA-plasma and heparin-plasma samples were comparatively studied using matched sample pairs from 20 individuals from the Australian Imaging, Biomarkers and Lifestyle (AIBL) Study. We identified 442 proteins in common between EDTA-plasma and heparin-plasma samples. Overall agreement of the relative protein quantification between the sample pairs demonstrated that shotgun proteomics using workflows such as the ASAP 2 is suitable in analyzing heparin-plasma and that such sample type may be considered in large-scale clinical research studies. Moreover, the partial proteome coverage overlaps (e.g., ∼70%) showed that measures from heparin-plasma could be complementary to those obtained from EDTA-plasma.
Plasma and Muscle Myostatin in Relation to Type 2 Diabetes
Brandt, Claus; Nielsen, Anders R.; Fischer, Christian P.; Hansen, Jakob; Pedersen, Bente K.; Plomgaard, Peter
2012-01-01
Objective Myostatin is a secreted growth factor expressed in skeletal muscle tissue, which negatively regulates skeletal muscle mass. Recent animal studies suggest a role for myostatin in insulin resistance. We evaluated the possible metabolic role of myostatin in patients with type 2 diabetes and healthy controls. Design 76 patients with type 2 diabetes and 92 control subjects were included in the study. They were matched for age, gender and BMI. Plasma samples and biopsies from the vastus lateralis muscle were obtained to assess plasma myostatin and expression of myostatin in skeletal muscle. Results Patients with type 2 diabetes had higher fasting glucose (8.9 versus 5.1 mmol/L, P<0.001), plasma insulin (68.2 versus 47.2 pmol/L, P<0.002) and HOMA2-IR (1.6 versus 0.9, P<0.0001) when compared to controls. Patients with type 2 diabetes had 1.4 (P<0.01) higher levels of muscle myostatin mRNA content than the control subjects. Plasma myostatin concentrations did not differ between patients with type 2 diabetes and controls. In healthy controls, muscle myostatin mRNA correlated with HOMA2-IR (r = 0.30, P<0.01), plasma IL-6 (r = 0.34, P<0.05) and VO2 max (r = −0.26, P<0.05), however, no correlations were observed in patients with type 2 diabetes. Conclusions This study supports the idea that myostatin may have a negative effect on metabolism. However, the metabolic effect of myostatin appears to be overruled by other factors in patients with type 2 diabetes. PMID:22615949
Complement Factor D in Age-Related Macular Degeneration
Stanton, Chloe M.; Yates, John R.W.; den Hollander, Anneke I.; Seddon, Johanna M.; Swaroop, Anand; Stambolian, Dwight; Fauser, Sascha; Hoyng, Carel; Yu, Yi; Atsuhiro, Kanda; Branham, Kari; Othman, Mohammad; Chen, Wei; Kortvely, Elod; Chalmers, Kevin; Hayward, Caroline; Moore, Anthony T.; Dhillon, Baljean; Ueffing, Marius
2011-01-01
Purpose. To examine the role of complement factor D (CFD) in age-related macular degeneration (AMD) by analysis of genetic association, copy number variation, and plasma CFD concentrations. Methods. Single nucleotide polymorphisms (SNPs) in the CFD gene were genotyped and the results analyzed by binary logistic regression. CFD gene copy number was analyzed by gene copy number assay. Plasma CFD was measured by an enzyme-linked immunosorbent assay. Results. Genetic association was found between CFD gene SNP rs3826945 and AMD (odds ratio 1.44; P = 0.028) in a small discovery case-control series (462 cases and 325 controls) and replicated in a combined cohorts meta-analysis of 4765 cases and 2693 controls, with an odds ratio of 1.11 (P = 0.032), with the association almost confined to females. Copy number variation in the CFD gene was identified in 13 out of 640 samples examined but there was no difference in frequency between AMD cases (1.3%) and controls (2.7%). Plasma CFD concentration was measured in 751 AMD cases and 474 controls and found to be elevated in AMD cases (P = 0.00025). The odds ratio for those in the highest versus lowest quartile for plasma CFD was 1.81. The difference in plasma CFD was again almost confined to females. Conclusions. CFD regulates activation of the alternative complement pathway, which is implicated in AMD pathogenesis. The authors found evidence for genetic association between a CFD gene SNP and AMD and a significant increase in plasma CFD concentration in AMD cases compared with controls, consistent with a role for CFD in AMD pathogenesis. PMID:22003108
Crofford, L J; Kalogeras, K T; Mastorakos, G; Magiakou, M A; Wells, J; Kanik, K S; Gold, P W; Chrousos, G P; Wilder, R L
1997-04-01
Systemic symptoms in rheumatoid arthritis (RA) are mediated, at least in part, by elevated levels of circulating interleukin (IL)-6, and this cytokine is also a potent stimulus of the hypothalamic-pituitary-adrenal axis. To evaluate the 24-h circadian secretory dynamics of ACTH, cortisol, and IL-6 and their interactions in patients with early untreated RA, we recruited and studied five newly diagnosed, untreated RA patients early in the course of their disease and five age-, gender-, and race-matched control subjects. We collected serial blood samples over 24 h and measured plasma ACTH and cortisol every 30 min and IL-6 every hour. The 24-h collection was followed by administration of ovine CRH (oCRH) and post-oCRH serial blood samples over 2 h. We analyzed the 24-h overall levels of these hormones and their circadian variations and performed time-lagged cross-correlation analyses among them. The untreated RA patients had 24 h time-integrated plasma ACTH, plasma cortisol levels, and urinary free cortisol excretion that were not significantly different from control subjects, in spite of their disease activity. However, an earlier morning surge of plasma ACTH and cortisol in the patients was suggested. Plasma ACTH and cortisol responses to oCRH were similar in RA patients and controls. IL-6 levels were significantly increased in the RA patients compared with control subjects during the early morning hours (P < 0.05). There was pronounced circadian variation of plasma Il-6 levels. In the RA patients, we detected a positive temporal correlation between plasma levels of IL-6 and ACTH/cortisol, with elevated levels of IL-6 before the elevations of ACTH and cortisol by 1 and 2 h, respectively. In the same patients, we detected a negative effect of cortisol upon IL-6 exerted with a delay of 5 h. The data presented here suggest that although endogenous IL-6 may stimulate secretion of ACTH and cortisol, overall activity of the hypothalamic-pituitary-adrenal axis remains normal and apparently is insufficient to inhibit ongoing inflammation in early untreated RA patients.
Li, Han-Qing; Mei, Jian-Gang; Cao, Hong-Qin; Shao, Liang-Jing; Zhai, Yong-Ping
2017-12-01
To establish a multiple myeloma specimen bank applied for molecular biological researches and to explore the methods of specimen collection, transportation, storage, quality control and the management of specimen bank. Bone marrow and blood samples were collected from multiple myeloma patients, plasma cell sorting were operated after the separation of mononuclear cells from bone marrow specimens. The plasma cells were divided into 2 parts, one was added with proper amount of TRIzol and then kept in -80 °C refrigerator for subsequent RNA extraction, the other was added with proper amount of calf serum cell frozen liquid and then kept in -80 °C refrigerator for subsequent cryopreservation of DNA extraction after numbered respectively. Serum and plasma were separated from peripheral blood, specimens of serum and plasma were then stored at -80 °C refrigerator after registration. Meantime, the myeloma specimen information management system was established, managed and maintained by specially-assigned persons and continuous modification and improvement in the process of use as to facilitate the rapid collection, management, query of the effective samples and clinical data. A total of 244 portions plasma cells, 564 portions of serum, and 1005 portions of plasma were collected, clinical characters were documented. A multiple myeloma specimen bank have been established initially, which can provide quality samples and related clinical information for molecular biological research on multiple myeloma.
Nijenhuis, C M; Lucas, L; Rosing, H; Jamieson, G; Fox, J A; Schellens, J H M; Beijnen, J H
2016-08-01
Vosaroxin is a first-in-class anticancer quinolone derivative topoisomerase II inhibitor that is currently in development in combination with cytarabine for the treatment of acute myeloid leukemia (AML). To investigate vosaroxin pharmacokinetics (PK) in patients, liquid chromatography tandem mass spectrometry (LC-MS/MS) assays to quantify vosaroxin and the two metabolites N-desmethylvosaroxin and O-desmethylvosaroxin in human plasma and urine were developed and validated. Immediately after collection the samples were stored at -80°C. Prior to analysis, the plasma samples were subjected to protein precipitation and the urine samples were diluted. For both assays the reconstituted extracts were injected on a Symmetry Shield RP8 column and gradient elution was applied using 0.1% formic acid in water and acetonitrile-methanol (50:50, v/v). Analyses were performed with a triple quadruple mass spectrometer in positive-ion mode. A deuterated isotope of vosaroxin was used as internal standard for the quantification. The validated assays quantify vosaroxin and N-desmethylvosaroxin in the concentration range of 2-500ng/mL in plasma and urine. For O-desmethylvosaroxin the concentration range of 4-500ng/mL in plasma and urine was validated. Dilution integrity experiments show that samples can be diluted 25 fold in control matrix prior to analysis. The expanded concentration range for plasma and urine for vosaroxin and N-desmethylvosaroxin is therefore from 2 to 15,000ng/mL and in plasma for O-desmethylvosaroxin from 4 to 15,000ng/mL. Copyright © 2016 Elsevier B.V. All rights reserved.
The effects of cannabinoids on serum cortisol and prolactin in humans
Ranganathan, Mohini; Braley, Gabriel; Pittman, Brian; Cooper, Thomas; Perry, Edward; Krystal, John; D’Souza, Deepak Cyril
2010-01-01
Background Cannabis is one of the most widely used illicit substances, and there is growing interest in the therapeutic applications of cannabinoids. While known to modulate neuroendocrine function, the precise acute and chronic dose-related effects of cannabinoids in humans are not well-known. Furthermore, the existing literature on the neuroendocrine effects of cannabinoids is limited by small sample sizes (n=6–22), heterogeneous samples with regard to cannabis exposure (lumping users and nonusers), lack of controlling for chronic cannabis exposure, differing methodologies, and limited dose–response data. Delta-9-tetrahydrocannabinol (Δ-9-THC) was hypothesized to produce dose-related increases in plasma cortisol levels and decreases in plasma prolactin levels. Furthermore, relative to controls, frequent users of cannabis were hypothesized to show altered baseline levels of these hormones and blunted Δ-9-THC-induced changes of these hormones. Materials and methods Pooled data from a series of laboratory studies with multiple doses of intravenous Δ-9-THC in healthy control subjects (n=36) and frequent users of cannabis (n=40) was examined to characterize the acute, chronic, and acute on chronic effects of cannabinoids on plasma cortisol and prolactin levels. Hormone levels were measured before (baseline) and 70 min after administration of each dose of Δ-9-THC. Data were analyzed using linear mixed models with +70 min hormonal levels as the dependant variable and baseline hormonal level as the covariate. Results At socially relevant doses, Δ-9-THC raised plasma cortisol levels in a dose-dependent manner but frequent users showed blunted increases relative to healthy controls. Frequent users also had lower baseline plasma prolactin levels relative to healthy controls. Conclusions These group differences may be related to the development of tolerance to the neuroendocrine effects of cannabinoids. Alternatively, these results may reflect inherent differences in neuroendocrine function in frequent users of cannabis and not a consequence of cannabis use. PMID:19083209
Circulating microRNAs as Biomarkers for Detection of Autologous Blood Transfusion
Leuenberger, Nicolas; Schumacher, Yorck Olaf; Pradervand, Sylvain; Sander, Thomas; Saugy, Martial; Pottgiesser, Torben
2013-01-01
MicroRNAs (miRNAs) are small non-coding RNAs that regulate various biological processes. Cell-free miRNAs measured in blood plasma have emerged as specific and sensitive markers of physiological processes and disease. In this study, we investigated whether circulating miRNAs can serve as biomarkers for the detection of autologous blood transfusion, a major doping technique that is still undetectable. Plasma miRNA levels were analyzed using high-throughput quantitative real-time PCR. Plasma samples were obtained before and at several time points after autologous blood transfusion (blood bag storage time 42 days) in 10 healthy subjects and 10 controls without transfusion. Other serum markers of erythropoiesis were determined in the same samples. Our results revealed a distinct change in the pattern of circulating miRNAs. Ten miRNAs were upregulated in transfusion samples compared with control samples. Among these, miR-30b, miR-30c, and miR-26b increased significantly and showed a 3.9-, 4.0-, and 3.0-fold change, respectively. The origin of these miRNAs was related to pulmonary and liver tissues. Erythropoietin (EPO) concentration decreased after blood reinfusion. A combination of miRNAs and EPO measurement in a mathematical model enhanced the efficiency of autologous transfusion detection through miRNA analysis. Therefore, our results lay the foundation for the development of miRNAs as novel blood-based biomarkers to detect autologous transfusion. PMID:23840438
NASA Astrophysics Data System (ADS)
Zhang, Ying; Mao, Xuefei; Liu, Jixin; Wang, Min; Qian, Yongzhong; Gao, Chengling; Qi, Yuehan
2016-04-01
In this work, a solid sampling device consisting of a tungsten coil trap, porous carbon vaporizer and on-line ashing furnace of a Ni-Cr coil was interfaced with inductively coupled plasma mass spectrometry (ICP-MS). A modified double gas circuit system was employed that was composed of carrier and supplemental gas lines controlled by separate gas mass flow controllers. For Cd determination in food samples using the assembled solid sampling ICP-MS, the optimal ashing and vaporization conditions, flow rate of the argon-hydrogen (Ar/H2) (v:v = 24:1) carrier gas and supplemental gas, and minimum sampling mass were investigated. Under the optimized conditions, the limit of quantification was 0.5 pg and the relative standard deviation was within a 10.0% error range (n = 10). Furthermore, the mean spiked recoveries for various food samples were 99.4%-105.9% (n = 6). The Cd concentrations measured by the proposed method were all within the certified values of the reference materials or were not significantly different (P > 0.05) from those of the microwave digestion ICP-MS method, demonstrating the good accuracy and precision of the solid sampling ICP-MS method for Cd determination in food samples.
Cheon, Dong Huey; Nam, Eun Ji; Park, Kyu Hyung; Woo, Se Joon; Lee, Hye Jin; Kim, Hee Cheol; Yang, Eun Gyeong; Lee, Cheolju; Lee, Ji Eun
2016-01-04
While human plasma serves as a great source for disease diagnosis, low-molecular-weight (LMW) proteome (<30 kDa) has been shown to contain a rich source of diagnostic biomarkers. Here we employ top-down mass spectrometry to analyze the LMW proteoforms present in four types of human plasma samples pooled from three healthy controls (HCs) without immunoaffinity depletion and with depletion of the top two, six, and seven high-abundance proteins. The LMW proteoforms were first fractionated based on molecular weight using gel-eluted liquid fraction entrapment electrophoresis (GELFrEE). Then, the GELFrEE fractions containing up to 30 kDa were subjected to nanocapillary-LC-MS/MS, and the high-resolution MS and MS/MS data were processed using ProSightPC 3.0. As a result, a total of 442 LMW proteins and cleaved products, including those with post-translational modifications and single amino acid variations, were identified. From additional comparative analysis of plasma samples without immunoaffinity depletion between HCs and colorectal cancer (CRC) patients via top-down approach, tens of LMW proteoforms, including platelet factor 4, were found to show >1.5-fold changes between the plasma samples of HCs and CRC patients, and six of the LMW proteins were verified by Western blot analysis.
NASA Astrophysics Data System (ADS)
Sherman, Justin; Azzari, Phillip; Crilly, P. B.; Duke-Tinson, Omar; James, Royce W.; Karama, Jackson; Page, E. J.; Schlank, Carter; Zuniga, Jonathan
2014-10-01
CGAPL is conducting small investigations in plasma physics and magneto-hydrodynamics buoy positioning. For data management, we are developing capability to analyze/digitize data with a National Instruments Data Acquisition board, 2 MS/s sampling rate (long time scale), and an Express Octopus card, 125 MS/s sampling rate (short scale). Sampling at 12 bits precision, we use LabVIEW as a programing language; GUIs will control variables in 1 or more concurrent runs and monitor of diagnostics. HPX utilizes high density (1013 cm3 up), low pressure (.01 T) Ar gas (fill pressure: on 104 mTorr order). Helicon/W Mode plasmas become a diagnostics test-bed for other investigations and a tool for future spacecraft propulsion devices. Plasmas created by directing energy into gas-filled Pyrex tube; power supply and matching box, up to 250 W power in 20-100 MHz frequencies, provide energy to ignite. Uniform magnetic field needed to reach the W-Mode. We employ an electromagnet to B-field while an acceleration coil positions plasma in vacuum chamber, facilitating analysis. Initial field requirements and accuracy calibration have been completed. Progress on development and implementation of probes and DAQ/GUI system will be reported. Supported by U.S. DEPS Grant [HEL-JTO] PRWJFY13.
Laeger, T; Wirthgen, E; Piechotta, M; Metzger, F; Metges, C C; Kuhla, B; Hoeflich, A
2014-05-01
Hormones and metabolites act as satiety signals in the brain and play an important role in the control of feed intake (FI). These signals can reach the hypothalamus and brainstem, 2 major centers of FI regulation, via the blood stream or the cerebrospinal fluid (CSF). During the early lactation period of high-yielding dairy cows, the increase of FI is often insufficient. Recently, it has been demonstrated that insulin-like growth factors (IGF) may control FI. Thus, we asked in the present study if IGF-binding proteins (IGFBP) are regulated during the periparturient period and in response to feed restriction and therefore might affect FI as well. In addition, we specifically addressed conditional distribution of IGFBP in plasma and CSF. In one experiment, 10 multiparous German Holstein dairy cows were fed ad libitum and samples of CSF and plasma were obtained before morning feeding on d -20, -10, +1, +10, +20, and +40 relative to calving. In a second experiment, 7 cows in second mid-lactation were sampled for CSF and plasma after ad libitum feeding and again after feeding 50% of the previous ad libitum intake for 4 d. Intact IGFBP-2, IGFBP-3, and IGFBP-4 were detected in plasma by quantitative Western ligand blot analysis. In CSF, we were able to predominantly identify intact IGFBP-2 and a specific IGFBP-2 fragment containing detectable binding affinities for biotinylated IGF-II. Whereas plasma concentrations of IGFBP-2 and IGFBP-4 increased during the periparturient period, IGFBP-3 was unaffected over time. In CSF, concentrations of IGFBP-2, both intact and fragmented, were not affected during the periparturient period. Plasma IGF-I continuously decreased until calving but remained at a lower concentration in early lactation than in late pregnancy. Food restriction did not affect concentrations of IGF components present in plasma or CSF. We could show that the IGFBP profiles in plasma and CSF are clearly distinct and that changes in IGFBP in plasma do not simply correspond in the brain. We thus assume independent control of IGFBP distribution between plasma and CSF. Due to the known anorexic effect of IGF-I, elevated plasma concentrations of IGFBP-2 and IGFBP-4 during the postpartum period in conjunction with reduced plasma IGF-I concentrations may be interpreted as an endocrine response against negative energy balance in early lactation in dairy cows. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Li, Xiaolin; Wu, Tong; Jiang, Yongjun; Zhang, Zining; Han, Xiaoxu; Geng, Wenqing; Ding, Haibo; Kang, Jing; Wang, Qi; Shang, Hong
2018-05-16
The goal of this study is to profile the metabolic changes in the plasma of HIV patients receiving lopinavir/ritonavir (LPV/r)-based highly active antiretroviral therapy (HAART) relative to their treatment-naïve phase, aimed to identify precision therapy for HIV for improving prognosis and predicting dyslipidemia caused by LPV/r. 38 longitudinal plasma samples were collected from 19 HIV-infected patients both before and after antiretroviral therapy, and 18 samples from healthy individuals were used as controls. Untargeted metabolomics profiling of these plasma samples was performed using liquid chromatography-mass spectrometry (LC-MS) and gas chromatography-mass spectrometry (GC-MS). A total of 331 compounds of known identity were detected among these metabolites, a 67-metabolite signature mainly mapping to tryptophan, histidine, acyl carnitine, ketone bodies and fatty acid metabolism distinguished HIV patients from healthy controls. The levels of 19 out of the 67 altered metabolites including histidine, kynurenine, and 3-hydroxybutyrate (BHBA), recovered after LPV/r-based antiretroviral therapy, and histidine was positively correlated with the presence of CD4 + T lymphocytes. Furthermore, using receiver operating characteristic (ROC) analyses, we discovered that butyrylcarnitine in combination with myristic acid from plasma in treatment-naïve patients could predict dyslipidemia caused by LPV/r with 87% accuracy. Metabolites alterations in treatment-naïve HIV patients may indicate an inflammatory, oxidative state and mitochondrial dysfunction that is permissive for disease progression. Histidine may provide a specific protective function for HIV patients. Besides, elevated fatty acids levels including butyrylcarnitine and myristic acid after infection may indicate patients at risk of suffering from dyslipidemia after LPV/r-based HAART. Copyright © 2018 Elsevier Ltd. All rights reserved.
Mori, K
1989-03-01
The present study was undertaken to clarify the low erythrocyte (RBC) alpha-tocopherol (TOC) concentrations in patients on maintenance hemodialysis (HD) using in vivo and in vitro experiments. 15 age-matched male controls and HD patients were evaluated. The experimental designs and the results were as follows: 1) Changes in fasting stage; TOC levels of plasma, high density lipoproteins (HDL) and RBC, especially RBC, were lower in HD-patients than in controls. The ratio of RBC to plasma and HDL showed more significant changes between HD-patients and controls. In controls, RBC-TOC was noted to have a positive correlation with HDL-TOC and a negative correlation with non HDL-(plasma--HDL)-TOC, whereas a reverse correlation was observed in HD-patients. 2) In vivo experiments: Each 7 of HD-patients and controls were orally given TOC 600 mg after meal at early morning; the blood was sampled at 0, 3, 6, 10 and 24 hr. Poor increase of RBC-TOC in HD-patients was observed. In contrast, HDL-TOC was significantly higher at all measurement times than in controls. The change of plasma-TOC was similar to that of non HDL-TOC. 3) In vitro experiment:RBC from patients or controls showing various concentrations of RBC-TOC and plasma from controls were incubated at 37 degrees C or 4 degrees C. The inactivated plasma from controls was prepared by incubation at 56 degrees C, 30 min or by supplement of 2 mM parachloromerucuric benzonic sulfonate. The ratio of RBC and plasma was at 2:3 close to physiological conditions. No difference between patient and control RBCs as an acceptor of TOC and no appreciable transfer of TOC between RBC to plasma at 4 degrees C were observed. When RBC-TOC was low, transfer volume of TOC from plasma to RBC was increased and TOC was supplied from mainly non HDL fractions; in contrast, when it was high, the main source of TOC was due to the transfer from HDL fractions which was reduced when lecithin: cholesterol acyltransferase (LCAT) reaction was inhibited. From above in vivo and in vitro studies, it was concluded that low levels of RBC-TOC in HD-patients may be due to an insufficiency of TOC transfer from HDL fractions affected by low LCAT activity.
Study of plasma-derived miRNAs mimic differences in Huntington's disease brain.
Hoss, Andrew G; Lagomarsino, Valentina N; Frank, Samuel; Hadzi, Tiffany C; Myers, Richard H; Latourelle, Jeanne C
2015-12-01
Biomarkers for Huntington's disease progression could accelerate therapeutic developments and improve patient care. Brain microRNAs relating to clinical features of Huntington's disease may represent a potential Huntington's disease biomarker in blood. This study was undertaken to examine candidate microRNAs in plasma to determine whether changes observed in HD brains are detectable in peripheral samples. Four microRNAs from 26 manifest Huntington's disease, four asymptomatic Huntington's disease gene carriers, and eight controls were quantified in plasma using reverse transcription quantitative polymerase chain reaction. Linear regression was used to assess microRNA levels across control, asymptomatic gene carriers, and manifest patients. miR-10b-5p (P = 0.0068) and miR-486-5p (P = 0.044) were elevated in Huntington's disease plasma. miR-10b-5p was decreased in asymptomatic gene carriers as compared with patients with Huntington's disease (P = 0.049), but no difference between asymptomatic gene carriers and healthy controls was observed (P = 0.24). These findings suggest that microRNA changes observed in Huntington's disease brain may be detectable in plasma and have potential clinical utility. © 2015 International Parkinson and Movement Disorder Society.
Inabu, Y; Fischer, A; Song, Y; Guan, L L; Oba, M; Steele, M A; Sugino, T
2018-07-01
Glucagon-like peptide (GLP)-1 is involved in glucose homeostasis via its role in stimulating insulin secretion, whereas GLP-2 increases mucosal growth of the small intestine. To our knowledge, the effect of delayed colostrum feeding on plasma GLP-1 and GLP-2 in neonatal calves has not been evaluated. To investigate the effect of delayed colostrum feeding on plasma concentrations of GLP-1 and GLP-2 in newborn calves, we randomly assigned 27 Holstein bull calves to 1 of 3 treatment groups: those fed colostrum within 1 h after birth (control), 6 h after birth (6H), and 12 h after birth (12H; n = 9 for each treatment). Blood samples were obtained before the colostrum feeding and every 3 h after each colostrum feeding for a 36-h period, and plasma concentrations of GLP-1, GLP-2, insulin, and glucose were measured. Plasma GLP-1 concentration at 12 h after colostrum feeding was lower in 12H than in control calves. In addition, plasma insulin concentration was lower in the 6H and 12H calves than in the controls. Plasma glucose and GLP-2 concentrations were, however, not affected by treatment. These results indicate that delayed colostrum feeding can decrease plasma GLP-1 and insulin concentrations without affecting glucose or GLP-2 concentration. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Cohen, Paul A; Flowers, Nicola; Tong, Stephen; Hannan, Natalie; Pertile, Mark D; Hui, Lisa
2016-08-24
Non-invasive prenatal testing (NIPT) identifies fetal aneuploidy by sequencing cell-free DNA in the maternal plasma. Pre-symptomatic maternal malignancies have been incidentally detected during NIPT based on abnormal genomic profiles. This low coverage sequencing approach could have potential for ovarian cancer screening in the non-pregnant population. Our objective was to investigate whether plasma DNA sequencing with a clinical whole genome NIPT platform can detect early- and late-stage high-grade serous ovarian carcinomas (HGSOC). This is a case control study of prospectively-collected biobank samples comprising preoperative plasma from 32 women with HGSOC (16 'early cancer' (FIGO I-II) and 16 'advanced cancer' (FIGO III-IV)) and 32 benign controls. Plasma DNA from cases and controls were sequenced using a commercial NIPT platform and chromosome dosage measured. Sequencing data were blindly analyzed with two methods: (1) Subchromosomal changes were called using an open source algorithm WISECONDOR (WIthin-SamplE COpy Number aberration DetectOR). Genomic gains or losses ≥ 15 Mb were prespecified as "screen positive" calls, and mapped to recurrent copy number variations reported in an ovarian cancer genome atlas. (2) Selected whole chromosome gains or losses were reported using the routine NIPT pipeline for fetal aneuploidy. We detected 13/32 cancer cases using the subchromosomal analysis (sensitivity 40.6 %, 95 % CI, 23.7-59.4 %), including 6/16 early and 7/16 advanced HGSOC cases. Two of 32 benign controls had subchromosomal gains ≥ 15 Mb (specificity 93.8 %, 95 % CI, 79.2-99.2 %). Twelve of the 13 true positive cancer cases exhibited specific recurrent changes reported in HGSOC tumors. The NIPT pipeline resulted in one "monosomy 18" call from the cancer group, and two "monosomy X" calls in the controls. Low coverage plasma DNA sequencing used for prenatal testing detected 40.6 % of all HGSOC, including 38 % of early stage cases. Our findings demonstrate the potential of a high throughput sequencing platform to screen for early HGSOC in plasma based on characteristic multiple segmental chromosome gains and losses. The performance of this approach may be further improved by refining bioinformatics algorithms and targeting selected cancer copy number variations.
Ring, Andrej; Langer, Stefan; Tilkorn, Daniel; Goertz, Ole; Henrich, Lena; Stricker, Ingo; Steinau, Hans-Ulrich; Steinstraesser, Lars; Hauser, Joerg
2010-09-28
Formation of encapsulating, avascular fibrous tissue is deemed to decrease implant's biocompatibility and versatility. We investigated whether plasma-mediated collagen coating possesses the ability to enhance neovascularization in the vicinity of silicone implants. Plasma-treated collagen-I-coated silicone samples were placed into the dorsal skinfold chambers of female balb/c mice (n = 10). Conventional silicone served as control (n = 10). Intravital microscopy was performed within implant's surrounding tissue on days 1, 5, and 10. Functional vessel density, intervascular distance, vessel diameter, microvascular permeability, red blood cell velocity, and leukocyte-endothelium interaction were determined. Enhanced angiogenesis in the tissue surrounding plasma-pretreated collagen-coated implants was noted. Significant increase of functional vessel density due to vascular new development was observed (t test, P < .05). Analyses of microvascular permeability and red blood cell velocity displayed stable perfusion of the vascular network neighboring the surface-modified implants. Intensified vascularity due to induced angiogenesis and neovascularization in the tissue surrounding plasma-collagen-coated samples were observed. These results indicate that plasma-mediated collagen coating might be a promising technology in order to improve the biocompatibility and versatility of silicone implants.
Ring, Andrej; Langer, Stefan; Tilkorn, Daniel; Goertz, Ole; Henrich, Lena; Stricker, Ingo; Steinau, Hans-Ulrich; Steinstraesser, Lars; Hauser, Joerg
2010-01-01
Objective: Formation of encapsulating, avascular fibrous tissue is deemed to decrease implant's biocompatibility and versatility. We investigated whether plasma-mediated collagen coating possesses the ability to enhance neovascularization in the vicinity of silicone implants. Methods: Plasma-treated collagen-I–coated silicone samples were placed into the dorsal skinfold chambers of female balb/c mice (n = 10). Conventional silicone served as control (n = 10). Intravital microscopy was performed within implant's surrounding tissue on days 1, 5, and 10. Functional vessel density, intervascular distance, vessel diameter, microvascular permeability, red blood cell velocity, and leukocyte-endothelium interaction were determined. Results: Enhanced angiogenesis in the tissue surrounding plasma-pretreated collagen-coated implants was noted. Significant increase of functional vessel density due to vascular new development was observed (t test, P < .05). Analyses of microvascular permeability and red blood cell velocity displayed stable perfusion of the vascular network neighboring the surface-modified implants. Conclusion: Intensified vascularity due to induced angiogenesis and neovascularization in the tissue surrounding plasma-collagen–coated samples were observed. These results indicate that plasma-mediated collagen coating might be a promising technology in order to improve the biocompatibility and versatility of silicone implants. PMID:20936137
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ballermann, B.J.
To enable serial measurements of plasma atrial natriuretic peptide (ANP) concentrations in the rat, a microradioreceptor assay (RRA) for this hormone was developed. Glomerular microsomes bearing ANP receptors were used to bind ANP. The smallest quantity of ANP detectable by this method was 0.2 fmol/sample. By contrast, a radioimmunoassay for ANP was sensitive to 2.4 fmol/sample. The intra- and interassay coefficients of variation for the RRA were 4.1 and 11.6%, respectively. Recovery of 10, 20, 50, and 100 pM synthetic ANP added to unextracted rat plasma was essentially 100%. Biologically inactive, synthetic amino- and carboxy-terminal ANP fragments added to ratmore » plasma were not detected. Plasma ANP was stable when measured four consecutive times at 90-min intervals in 10 fasting rats. In a separate group of rats, fasting plasma ANP levels averaged 34 {plus minus} 3 and rose to 57 {plus minus} 5 pM in the postprandial state, whereas levels in fasting time controls remained constant. It is concluded that the RRA for ANP described here detects ANP in microliter quantities of unextracted rat plasma. Thus serial measurements of ANP concentrations can be undertaken in rats without inducing major changes in the volume status.« less
Price, Richard W; Parham, Robin; Kroll, Jing Lu; Wring, Stephen A; Baker, Brian; Sailstad, Jeff; Hoh, Rebecca; Liegler, Teri; Spudich, Serena; Kuritzkes, Daniel R; Deeks, Steven G
2008-01-01
Enfuvirtide is a potent inhibitor of systemic HIV-1 replication, but its penetration into the human central nervous system (CNS) has not been analysed. Here, we define cerebrospinal fluid (CSF) enfuvirtide pharmacokinetics and present a case illustrating the use of enfuvirtide as a probe to trace the origins of CSF HIV-1 quasispecies. Enfuvirtide CSF pharmacokinetics were assessed in 18 CSF and plasma sample pairs from four HIV-1-infected individuals. Enfuvirtide levels were measured by liquid chromatography tandem mass spectrometry using known standards and controls that included spiked CSF samples from untreated, HIV-negative individuals. A segment of the gp41 coding region encompassing the heptad repeat HR-1 and HR-2 domains was amplified from selected CSF and plasma samples and independent clones sequenced to assess resistance-associated mutations. CSF and plasma samples obtained between 2 and 20 h after enfuvirtide injection showed plasma concentrations similar to previous reports (mean 3.687 SD +/- 1.828 mg/ml) with prolonged decay. By contrast, enfuvirtide in all CSF samples was below the assay detection limit of 0.025 mg/ml. In one individual, who developed a transient increase in CSF HIV-1 RNA, seven of seven CSF and plasma clones had identical enfuvirtide resistance-associated V38A mutations, suggesting that the CSF quasispecies derived from that of blood. Enfuvirtide penetration into CSF is negligible; thus, in clinical settings, where direct CNS drug exposure is crucial, this drug Is not likely to directly contribute to the local therapeutic effect. Enfuvirtide can be used as a tool to dissect the origin of the CNS virus.
Hawkins, Michelle G; Kass, Philip H; Zinkl, Joseph G; Tell, Lisa A
2006-06-01
To the authors' knowledge, on the basis of sample type, storage condition, or hemolysis, differences in serum and plasma biochemical values have not been evaluated in orange-winged Amazon parrots (Amazona amazonica). The purpose of this study was to compare values for biochemical analytes in serum vs plasma, fresh vs frozen plasma, and nonhemolyzed vs hemolyzed samples in orange-winged Amazon parrots. We also compared differences in serum and plasma yield from whole-blood aliquots. Fifteen biochemical analytes were evaluated in paired serum and plasma, fresh and frozen plasma, nonhemolyzed and hemolyzed serum and plasma samples from orange-winged Amazon parrots (n = 10) using a wet reagent analyzer. Hemolysis was assessed qualitatively (visually) and quantitatively (hemoglobin [Hgb] measured spectrophotometrically). Serum and plasma yields from 500-microl whole-blood aliquots were determined from centrifuged samples. Analyte values significantly differed among sample groups, but were still within published reference intervals, with the exception of increases in potassium concentration in markedly hemolyzed serum and plasma samples. Clinically important changes in hemolyzed serum and plasma samples included increases in potassium, phosphorus, and albumin concentrations and lactate dehydrogenase activity. The degree of hemolysis assigned qualitatively did not correlate with quantitative Hgb concentration. A significantly greater yield of plasma (288 +/- 13 microL) than serum (241 +/- 44 microL) was obtained. Significant differences may occur in different sample types, however, only changes in potassium, phosphorus, albumin, and lactate dehydrogenase values in hemolyzed samples were considered clinically relevant. Lack of agreement between qualitative and quantitative Hgb concentration indicates the unreliability of visual estimation. Based on higher sample yield, and lack of clinically relevant differences from serum, plasma is a better sample choice for clinical chemistry analysis in birds.
Plasma exosomal α-synuclein is likely CNS-derived and increased in Parkinson’s disease
Cook, Travis J.; Bullock, Kristin M.; Zhao, Yanchun; Ginghina, Carmen; Li, Yanfei; Aro, Patrick; Dator, Romel; He, Chunmei; Hipp, Michael J.; Zabetian, Cyrus P.; Peskind, Elaine R.; Hu, Shu-Ching; Quinn, Joseph F.; Galasko, Douglas R.; Banks, William A.; Zhang, Jing
2014-01-01
Extracellular α-synuclein is important in the pathogenesis of Parkinson disease (PD) and also as a potential biomarker when tested in the cerebrospinal fluid (CSF). The performance of blood plasma or serum α-synuclein as a biomarker has been found to be inconsistent and generally ineffective, largely due to the contribution of peripherally derived α-synuclein. In this study, we discovered, via an intracerebroventricular injection of radiolabeled α-synuclein into mouse brain, that CSF α-synuclein was readily transported to blood, with a small portion being contained in exosomes that are relatively specific to the central nervous system (CNS). Consequently, we developed a technique to evaluate the levels of α-synuclein in these exosomes in individual plasma samples. When applied to a large cohort of clinical samples (267 PD, 215 controls), we found that in contrast to CSF α-synuclein concentrations, which are consistently reported to be lower in PD patients compared to controls, the levels of plasma exosomal α-synuclein were substantially higher in PD patients, suggesting an increased efflux of the protein to the peripheral blood of these patients. Furthermore, although no association was observed between plasma exosomal and CSF α-synuclein, a significant correlation between plasma exosomal α-synuclein and disease severity (r=0.176, p=0.004) was observed, and the diagnostic sensitivity and specificity achieved by plasma exosomal α-synuclein were comparable to those determined by CSF α-synuclein. Further studies are clearly needed to elucidate the mechanism involved in the transport of CNS α-synuclein to the periphery, which may lead to a more convenient and robust assessment of PD clinically. PMID:24997849
Pavlovian autoshaping procedures increase plasma corticosterone levels in rats.
Tomie, Arthur; Silberman, Yuval; Williams, Kayon; Pohorecky, Larissa A
2002-06-01
Pavlovian autoshaping conditioned responses (CRs) are complex sequences of conditioned stimulus (CS)-directed skeletal-motor responses that are elicited by CS objects predictive of food unconditioned stimulus (US). Autoshaping CRs are observed under conditions known to be conducive to elevations in plasma corticosterone levels, as, for example, in response to the eating of food as well as in response to signals predictive of food. Two experiments investigated the relationships between Pavlovian autoshaping procedures, the performance of Pavlovian autoshaping CRs, and plasma corticosterone levels in male Long-Evans rats. In Experiment 1, rats in the CS-US paired group (n=30) were given 20 daily sessions of Pavlovian autoshaping training wherein the insertion of a retractable lever CS was followed by the response-independent presentation of the food US. Tail blood samples obtained after the 20th autoshaping session revealed higher plasma corticosterone levels in the CS-US paired group than in the CS-US random control group (n=10). In Experiment 2, rats (n=35) were assessed for basal plasma corticosterone levels 2 weeks prior to autoshaping training. Plasma samples obtained immediately following the first autoshaping session, and prior to the acquisition of lever-press autoshaping CR performance, revealed higher plasma corticosterone levels in the CS-US paired group (n=24) relative to basal levels. This effect was not observed in the CS-US random control group (n=11). Data suggest that corticosterone release is a physiological endocrine Pavlovian CR induced by lever CS-food US pairings during Pavlovian autoshaping procedures, rather than a by-product of autoshaping CR performance. Implications of the link between autoshaping procedures and corticosterone release are discussed.
Plasma Lipids and Betaine Are Related in an Acute Coronary Syndrome Cohort
Lever, Michael; George, Peter M.; Atkinson, Wendy; Molyneux, Sarah L.; Elmslie, Jane L.; Slow, Sandy; Richards, A. Mark; Chambers, Stephen T.
2011-01-01
Background Low plasma betaine has been associated with unfavorable plasma lipid profiles and cardiovascular risk. In some studies raised plasma betaine after supplementation is associated with elevations in plasma lipids. We aimed to measure the relationships between plasma and urine betaine and plasma lipids, and the effects of lipid-lowering drugs on these. Methodology Fasting plasma samples were collected from 531 subjects (and urine samples from 415) 4 months after hospitalization for an acute coronary syndrome episode. In this cross-sectional study, plasma betaine and dimethylglycine concentrations and urine excretions were compared with plasma lipid concentrations. Subgroup comparisons were made for gender, with and without diabetes mellitus, and for drug treatment. Principal Findings Plasma betaine negatively correlated with triglyceride (Spearman's rs = −0.22, p<0.0001) and non-high-density lipoprotein cholesterol (rs = −0.27, p<0.0001). Plasma betaine was a predictor of BMI (p<0.05) and plasma non-high-density lipoprotein cholesterol and triglyceride (p<0.001) independently of gender, age and the presence of diabetes. Using data grouped by plasma betaine decile, increasing plasma betaine was linearly related to decreases in BMI (p = 0.008) and plasma non-HDL cholesterol (p = 0.002). In a non-linear relationship betaine was negatively associated with elevated plasma triglycerides (p = 0.004) only for plasma betaine >45 µmol/L. Subjects taking statins had higher plasma betaine concentrations (p<0.001). Subjects treated with a fibrate had lower plasma betaine (p = 0.003) possibly caused by elevated urine betaine loss (p<0.001). The ratio of coenzyme Q to non-high-density lipoprotein cholesterol was higher in subjects with higher plasma betaine, and in subjects taking a statin. Conclusion Low plasma betaine concentrations correlated with an unfavourable lipid profile. Betaine deficiency may be common in the study population. Controlled clinical trials of betaine supplementation should be conducted in appropriate populations to determine whether correction affects cardiovascular risk. PMID:21747945
2000-03-01
Lipid peroxidation may be increased in schizophrenia, due to the illness, lifestyle or medication. To determine plasma lipid peroxide levels and serum vitamin E and A levels in first-episode never-treated people with schizophrenia and in controls. Thirty in-patients with a first episode of schizophrenia or schizophreniform psychosis were recruited, as were controls matched for gender, age, smoking and dietary status. Blood samples were taken, smoking status was recorded and body mass index measured. There were no significant differences between patients and controls in plasma peroxide levels. Seventy-three per cent of the patients smoked. Patients who smoked had a higher mean lipid peroxide level than non-smokers. Seventy-seven per cent of patients and 70% of controls had a ratio of vitamin E to cholesterol of less than 5. Body mass index was lower in patients than in controls. As a result of the high prevalence of smoking this group shows increased lipid peroxidation. Low serum ratios of vitamin E to cholesterol in both patients and controls suggest an unsatisfactory diet.
Total Extracellular Small RNA Profiles from Plasma, Saliva, and Urine of Healthy Subjects
Yeri, Ashish; Courtright, Amanda; Reiman, Rebecca; Carlson, Elizabeth; Beecroft, Taylor; Janss, Alex; Siniard, Ashley; Richholt, Ryan; Balak, Chris; Rozowsky, Joel; Kitchen, Robert; Hutchins, Elizabeth; Winarta, Joseph; McCoy, Roger; Anastasi, Matthew; Kim, Seungchan; Huentelman, Matthew; Van Keuren-Jensen, Kendall
2017-01-01
Interest in circulating RNAs for monitoring and diagnosing human health has grown significantly. There are few datasets describing baseline expression levels for total cell-free circulating RNA from healthy control subjects. In this study, total extracellular RNA (exRNA) was isolated and sequenced from 183 plasma samples, 204 urine samples and 46 saliva samples from 55 male college athletes ages 18–25 years. Many participants provided more than one sample, allowing us to investigate variability in an individual’s exRNA expression levels over time. Here we provide a systematic analysis of small exRNAs present in each biofluid, as well as an analysis of exogenous RNAs. The small RNA profile of each biofluid is distinct. We find that a large number of RNA fragments in plasma (63%) and urine (54%) have sequences that are assigned to YRNA and tRNA fragments respectively. Surprisingly, while many miRNAs can be detected, there are few miRNAs that are consistently detected in all samples from a single biofluid, and profiles of miRNA are different for each biofluid. Not unexpectedly, saliva samples have high levels of exogenous sequence that can be traced to bacteria. These data significantly contribute to the current number of sequenced exRNA samples from normal healthy individuals. PMID:28303895
Stevenson, Erika T; Gese, Eric M; Neuman-Lee, Lorin A; French, Susannah S
2018-03-01
Knowledge of endocrine stress responses can be advantageous for understanding how animals respond to their environment. One tool in wildlife endocrinology is to measure the adrenocortical activity as a parameter of disturbance of animals. Fecal glucocorticoid metabolites (GCMs) provide a noninvasive assessment of adrenocortical activity. Using an adrenocorticotropic hormone (ACTH) challenge administered to 28 captive coyotes (Canis latrans), we measured the levels of plasma cortisol, and fecal cortisol and corticosterone metabolites (i.e., GCMs). Our goal was to determine the dose-response in the plasma and fecal samples following the injection and determine if there were effects of sex, age, and time of day. Specifically, animals were anesthetized for ~ 90 min with treatment animals intravenously injected with exogenous ACTH and control animals receiving saline. We collected blood samples prior to injection and at 4 different time points post-injection. We also collected fecal samples 2 days pre- and 2 days post-injection to measure fecal GCMs and determine if an endocrine stress response could be detected in fecal samples. We found a definite response in cortisol levels in the plasma for coyotes to the ACTH challenge. There was a response in fecal corticosterone 1 day post-injection, but the control males showed a similar response indicating a handling effect. Fecal cortisol levels did not indicate a response to the ACTH challenge, and were significantly lower than corticosterone concentrations. We also found significant sex, but not age or diurnal, differences in fecal GCMs. Radioimmunoassays for fecal corticosterone levels appeared to be a reliable indicator of physiological stress in coyotes.
Seo, Sang-Hee; Uhm, Soo-Hyuk; Kwon, Jae-Sung; Choi, Eun Ha; Kim, Kwang-Mahn; Kim, Kyoung-Nam
2015-03-01
Titanium oxide nanotube layer formed by plasma electrolytic oxidation (PEO) is known to be excellent in biomaterial applications. However, the annealing process which is commonly performed on the TiO2 nanotubes cause defects in the nanotubular structure. The purpose of this work was to apply a non-thermal atmospheric pressure plasma jet on diameter-controlled TiO2 nanotubes to mimic the effects of annealing while maintaining the tubular structure for use as biomaterial. Diameter-controlled nanotube samples fabricated by plasma electrolytic oxidation were dried and prepared under three different conditions: untreated, annealed at 450 °C for 1 h in air with a heating rate of 10 °C/min, and treated with an air-based non-thermal atmospheric pressure plasma jet for 5 minutes. The contact angle measurement was investigated to confirm the enhanced hydrophilicity of the TiO2 nanotubes. The chemical composition of the surface was studied using X-ray photoelectron spectroscopy, and the morphology of TiO2 nanotubes was examined by field emission scanning electron microscopy. For the viability of the cell, the attachment of the osteoblastic cell line MC3T3-E1 was determined using the water-soluble tetrazolium salt assay. We found that there are no morphological changes in the TiO2 nanotubular structure after the plasma treatment. Also, we investigated a change in the chemical composition and enhanced hydrophilicity which result in improved cell behavior. The results of this study indicated that the non-thermal atmospheric pressure plasma jet results in osteoblast functionality that is comparable to annealed samples while maintaining the tubular structure of the TiO2 nanotubes. Therefore, this study concluded that the use of a non-thermal atmospheric pressure plasma jet on nanotube surfaces may replace the annealing process following plasma electrolytic oxidation.
White, P Lewis; Barnes, Rosemary A; Springer, Jan; Klingspor, Lena; Cuenca-Estrella, Manuel; Morton, C Oliver; Lagrou, Katrien; Bretagne, Stéphane; Melchers, Willem J G; Mengoli, Carlo; Donnelly, J Peter; Heinz, Werner J; Loeffler, Juergen
2015-09-01
Aspergillus PCR testing of serum provides technical simplicity but with potentially reduced sensitivity compared to whole-blood testing. With diseases for which screening to exclude disease represents an optimal strategy, sensitivity is paramount. The associated analytical study confirmed that DNA concentrations were greater in plasma than those in serum. The aim of the current investigation was to confirm analytical findings by comparing the performance of Aspergillus PCR testing of plasma and serum in the clinical setting. Standardized Aspergillus PCR was performed on plasma and serum samples concurrently obtained from hematology patients in a multicenter retrospective anonymous case-control study, with cases diagnosed according to European Organization for Research and Treatment of Cancer/Invasive Fungal Infections Cooperative Group and the National Institute of Allergy and Infectious Diseases Mycoses Study Group (EORTC/MSG) consensus definitions (19 proven/probable cases and 42 controls). Clinical performance and clinical utility (time to positivity) were calculated for both kinds of samples. The sensitivity and specificity for Aspergillus PCR when testing serum were 68.4% and 76.2%, respectively, and for plasma, they were 94.7% and 83.3%, respectively. Eighty-five percent of serum and plasma PCR results were concordant. On average, plasma PCR was positive 16.8 days before diagnosis and was the earliest indicator of infection in 13 cases, combined with other biomarkers in five cases. On average, serum PCR was positive 10.8 days before diagnosis and was the earliest indicator of infection in six cases, combined with other biomarkers in three cases. These results confirm the analytical finding that the sensitivity of Aspergillus PCR using plasma is superior to that using serum. PCR positivity occurs earlier when testing plasma and provides sufficient sensitivity for the screening of invasive aspergillosis while maintaining methodological simplicity. Copyright © 2015 White et al.
Insight into hydrogenation of graphene: Effect of hydrogen plasma chemistry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Felten, A.; Nittler, L.; Pireaux, J.-J.
2014-11-03
Plasma hydrogenation of graphene has been proposed as a tool to modify the properties of graphene. However, hydrogen plasma is a complex system and controlled hydrogenation of graphene suffers from a lack of understanding of the plasma chemistry. Here, we correlate the modifications induced on monolayer graphene studied by Raman spectroscopy with the hydrogen ions energy distributions obtained by mass spectrometry. We measure the energy distribution of H{sup +}, H{sub 2}{sup +}, and H{sub 3}{sup +} ions for different plasma conditions showing that their energy strongly depends on the sample position, pressure, and plasma power and can reach values asmore » high as 45 eV. Based on these measurements, we speculate that under specific plasma parameters, protons should possess enough energy to penetrate the graphene sheet. Therefore, a graphene membrane could become, under certain conditions, transparent to both protons and electrons.« less
Lifschitz, A; Virkel, G; Pis, A; Imperiale, F; Sanchez, S; Alvarez, L; Kujanek, R; Lanusse, C
1999-10-01
Slight differences in formulation may change the plasma kinetics and ecto-endoparasiticide activity of endectocide compounds. This work reports on the disposition kinetics and plasma availability of ivermectin (IVM) after subcutaneous (SC) and intramuscular (IM) administration as an oil-based formulation to cattle. Parasite-free Aberdeen Angus calves (n = 24; 240-280 kg) were divided into three groups (n = 8) and treated (200 microg/kg) with either an IVM oil-based pharmaceutical preparation (IVM-TEST formulation) (Bayer Argentina S.A.) given by subcutaneous (Group A) and intramuscular (Group B) injections or the IVM-CONTROL (non-aqueous formulation) (Ivomec, MSD Agvet) subcutaneously administered (Group C). Blood samples were taken over 35 days post-treatment and the recovered plasma was extracted and analyzed by HPLC using fluorescence detection. IVM was detected in plasma between 12 h and 35 days post-administration of IVM-TEST (SC and IM injections) and IVM-CONTROL formulations. Prolonged IVM absorption half-life (p < 0.05) and delayed peak plasma concentration (p < 0.001) were obtained following the SC administration of the IVM-TEST compared to the IVM-CONTROL formulation. No differences in total plasma availability were observed among treatments. However, the plasma residence time and elimination half-life of IVM were significantly longer after injection of the IVM-TEST formulation. IVM plasma concentrations were above 0.5 ng/ml for 20.6 (CONTROL) and 27.5 days (IVM-TEST SC), respectively (p < 0.05). The modified kinetic behaviour of IVM obtained after the administration of the novel oil-based formulation examined in this trial, compared to the standard preparation, may positively impact on its strategic use in cattle.
Circulating miR-132-3p as a Candidate Diagnostic Biomarker for Malignant Mesothelioma
Gawrych, Katarzyna; Casjens, Swaantje; Brik, Alexander; Lehnert, Martin; Taeger, Dirk; Pesch, Beate; Kollmeier, Jens; Bauer, Torsten T.; Johnen, Georg; Brüning, Thomas
2017-01-01
The use of circulating microRNAs as biomarkers has opened new opportunities for diagnosis of cancer because microRNAs exhibit tumor-specific expression profiles. The aim of this study was the identification of circulating microRNAs in human plasma as potential biomarkers for the diagnosis of malignant mesothelioma. For discovery, TaqMan Low Density Array Human MicroRNA Cards were used to analyze 377 microRNAs in plasma samples from 21 mesothelioma patients and 21 asbestos-exposed controls. For verification, individual TaqMan microRNA assays were used for quantitative real-time PCR in plasma samples from 22 mesothelioma patients and 44 asbestos-exposed controls. The circulating miR-132-3p showed different expression levels between mesothelioma patients and asbestos-exposed controls. For discrimination, sensitivity of 86% and specificity of 61% were calculated. Circulating miR-132-3p in plasma was not affected by hemolysis and no impact of age or smoking status on miR-132-3p levels could be observed. For the combination of miR-132-3p with the previously described miR-126, sensitivity of 77% and specificity of 86% were calculated. The results of this study indicate that miR-132-3p might be a new promising diagnostic biomarker for malignant mesothelioma. It is indicated that the combination of miR-132-3p with other individual biomarkers improves the biomarker performance. PMID:28321148
Abbatiello, Susan E.; Schilling, Birgit; Mani, D. R.; Zimmerman, Lisa J.; Hall, Steven C.; MacLean, Brendan; Albertolle, Matthew; Allen, Simon; Burgess, Michael; Cusack, Michael P.; Gosh, Mousumi; Hedrick, Victoria; Held, Jason M.; Inerowicz, H. Dorota; Jackson, Angela; Keshishian, Hasmik; Kinsinger, Christopher R.; Lyssand, John; Makowski, Lee; Mesri, Mehdi; Rodriguez, Henry; Rudnick, Paul; Sadowski, Pawel; Sedransk, Nell; Shaddox, Kent; Skates, Stephen J.; Kuhn, Eric; Smith, Derek; Whiteaker, Jeffery R.; Whitwell, Corbin; Zhang, Shucha; Borchers, Christoph H.; Fisher, Susan J.; Gibson, Bradford W.; Liebler, Daniel C.; MacCoss, Michael J.; Neubert, Thomas A.; Paulovich, Amanda G.; Regnier, Fred E.; Tempst, Paul; Carr, Steven A.
2015-01-01
There is an increasing need in biology and clinical medicine to robustly and reliably measure tens to hundreds of peptides and proteins in clinical and biological samples with high sensitivity, specificity, reproducibility, and repeatability. Previously, we demonstrated that LC-MRM-MS with isotope dilution has suitable performance for quantitative measurements of small numbers of relatively abundant proteins in human plasma and that the resulting assays can be transferred across laboratories while maintaining high reproducibility and quantitative precision. Here, we significantly extend that earlier work, demonstrating that 11 laboratories using 14 LC-MS systems can develop, determine analytical figures of merit, and apply highly multiplexed MRM-MS assays targeting 125 peptides derived from 27 cancer-relevant proteins and seven control proteins to precisely and reproducibly measure the analytes in human plasma. To ensure consistent generation of high quality data, we incorporated a system suitability protocol (SSP) into our experimental design. The SSP enabled real-time monitoring of LC-MRM-MS performance during assay development and implementation, facilitating early detection and correction of chromatographic and instrumental problems. Low to subnanogram/ml sensitivity for proteins in plasma was achieved by one-step immunoaffinity depletion of 14 abundant plasma proteins prior to analysis. Median intra- and interlaboratory reproducibility was <20%, sufficient for most biological studies and candidate protein biomarker verification. Digestion recovery of peptides was assessed and quantitative accuracy improved using heavy-isotope-labeled versions of the proteins as internal standards. Using the highly multiplexed assay, participating laboratories were able to precisely and reproducibly determine the levels of a series of analytes in blinded samples used to simulate an interlaboratory clinical study of patient samples. Our study further establishes that LC-MRM-MS using stable isotope dilution, with appropriate attention to analytical validation and appropriate quality control measures, enables sensitive, specific, reproducible, and quantitative measurements of proteins and peptides in complex biological matrices such as plasma. PMID:25693799
Lloyd, T L; Perschy, T B; Gooding, A E; Tomlinson, J J
1992-01-01
A fully automated assay for the analysis of ranitidine in serum and plasma, with and without an internal standard, was validated. It utilizes robotic solid phase extraction with on-line high performance liquid chromatographic (HPLC) analysis. The ruggedness of the assay was demonstrated over a three-year period. A Zymark Py Technology II robotic system was used for serial processing from initial aspiration of samples from original collection containers, to final direct injection onto the on-line HPLC system. Automated serial processing with on-line analysis provided uniform sample history and increased productivity by freeing the chemist to analyse data and perform other tasks. The solid phase extraction efficiency was 94% throughout the assay range of 10-250 ng/mL. The coefficients of variation for within- and between-day quality control samples ranged from 1 to 6% and 1 to 5%, respectively. Mean accuracy for between-day standards and quality control results ranged from 97 to 102% of the respective theoretical concentrations.
The use of frozen plasma samples in thromboelastometry.
Schoergenhofer, Christian; Buchtele, Nina; Schwameis, Michael; Bartko, Johann; Jilma, Bernd; Jilma-Stohlawetz, Petra
2017-11-01
Thromboelastometry is increasingly used in the clinical and scientific setting. The use of frozen plasma samples may be useful in overcoming certain limitations such as local and timely availability. Whole blood (WB) samples of 20 healthy volunteers were obtained, and plasma was generated. NATEM (n = 20), EXTEM (n = 20) and INTEM (n = 8) analyses were performed in WB, fresh plasma and frozen and thawed plasma. Dabigatran (500, 1000 ng/ml), rivaroxaban (100, 200 ng/ml) or alteplase (333 ng/ml) were added ex vivo to WB, and thromboelastometry was performed in WB and in frozen and thawed plasma samples. Clot formation time, mean clot firmness and the area under the curve were significantly altered in plasma compared to WB. In INTEM and EXTEM analysis, clotting time (CT) was comparable between WB (100%) and fresh (INTEM 114% and EXTEM 93%, ratio of the means) and frozen plasma samples (85 and 99%), whereas in NATEM analysis, the CT increased in fresh (193%) and frozen plasma samples (130%). Dabigatran dose-dependently increased the CT approximately 5- and 9-fold in WB and even more pronounced 10- and 26-fold in plasma. Accordingly, rivaroxaban dose-dependently increased the CT 2- and 2.7-fold in WB, and 3.5- and 4-fold in plasma samples. Hyperfibrinolysis was achieved by addition of alteplase in all WB samples and was reproducible in plasma samples. In conclusion, thromboelastometry, especially INTEM and EXTEM analyses, is possible using frozen and stored plasma samples with comparable results to the corresponding whole blood samples.
Hefnawy, Abd Elghany; Youssef, Seham; Aguilera, P. Villalobos; Rodríguez, C. Valverde; Pérez, J. L. Tórtora
2014-01-01
Twenty pregnant ewes were selected and classified into two groups. The first group received subcutaneous selenium supplementation (0.1 mg of sodium selenite/kg BW) at the 8th and 5th weeks before birth and 1st week after birth while the other was control group without selenium injection. Maternal plasma and serum samples were collected weekly from the 8th week before birth until the 8th week after birth and milk samples were taken from ewes weekly, while plasma and serum samples were collected at 48 hours, 1st, 2nd, 3rd, 5th, and 8th weeks after birth from the newborn lambs. Results demonstrated significant positive relationship between maternal plasma selenium and serum T3 in supplemented and control ewes (r = 0.69 to 0.72, P < 0.05). There was significant (P < 0.001) increase in T3 in supplemented ewes and their lambs until the 8th week after birth. There was positive relationship between milk, selenium concentration, and serum T3 in the newborn lambs of the supplemented group (r = 0.84, P < 0.01), while the relationship was negative in the control one (r = −0.89, P < 0.01). Muscular and thyroid pathological changes were independent of selenium supplementation. Selenium supplementation was important for maintaining T3 in ewes and newborn lambs until the 8th week after birth. PMID:24660087
Yang, Iseul; Kim, Ki Hun; Lee, Ju Yong; Moon, Myeong Hee
2014-01-10
A direct analytical method for high speed quantitative analysis of lipids in human blood plasma using on-line chip-type asymmetrical flow field-flow fractionation-electrospray ionization-tandem mass spectrometry (cAF4-ESI-MS/MS) with selected reaction monitoring (SRM) is described in this study. Utilizing a miniaturized cAF4 channel, high speed size separation of high density lipoproteins (HDL) and low density lipoproteins (LDL) from plasma samples can be accomplished at a microflow rate along with simultaneous desalting of lipoproteins, both of which are conducive to direct ESI of lipids in lipoproteins. This study demonstrates that the SRM method to monitor phospholipids during cAF4-ESI-MS/MS can be successfully applied to the quantitation of lipid molecules in plasma lipoproteins without the need of a separate lipid extraction process. For quantitation of lipids in HDL and LDL during cAF4-ESI-MS/MS runs, a protein standard (carbonic anhydrase, 29 kDa) was added to each plasma sample as an internal standard such that a peak intensity of y67(+5) ions, which are high abundant SRM product ions of CA, could be utilized to calculate the relative intensity of each lipid molecule. The developed method was applied to plasma samples from 10 patients with coronary artery disease (CAD) and 10 healthy control samples, and quantitative analysis of 39 lipid molecules including phosphatidylcholines, phosphatidylethanolamines, sphingomyelins, phosphatidylglycerols, and phosphatidylinositols, resulted in the selection of 13 PL species showing more than 2.5 fold difference in relative abundance (p<0.01) between the groups. The present study demonstrates a high speed analytical method for determining plasma lipid content and distribution without an organic solvent extraction of lipids from plasma. Copyright © 2013 Elsevier B.V. All rights reserved.
Three plasma metabolite signatures for diagnosing high altitude pulmonary edema
NASA Astrophysics Data System (ADS)
Guo, Li; Tan, Guangguo; Liu, Ping; Li, Huijie; Tang, Lulu; Huang, Lan; Ren, Qian
2015-10-01
High-altitude pulmonary edema (HAPE) is a potentially fatal condition, occurring at altitudes greater than 3,000 m and affecting rapidly ascending, non-acclimatized healthy individuals. However, the lack of biomarkers for this disease still constitutes a bottleneck in the clinical diagnosis. Here, ultra-high performance liquid chromatography coupled with Q-TOF mass spectrometry was applied to study plasma metabolite profiling from 57 HAPE and 57 control subjects. 14 differential plasma metabolites responsible for the discrimination between the two groups from discovery set (35 HAPE subjects and 35 healthy controls) were identified. Furthermore, 3 of the 14 metabolites (C8-ceramide, sphingosine and glutamine) were selected as candidate diagnostic biomarkers for HAPE using metabolic pathway impact analysis. The feasibility of using the combination of these three biomarkers for HAPE was evaluated, where the area under the receiver operating characteristic curve (AUC) was 0.981 and 0.942 in the discovery set and the validation set (22 HAPE subjects and 22 healthy controls), respectively. Taken together, these results suggested that this composite plasma metabolite signature may be used in HAPE diagnosis, especially after further investigation and verification with larger samples.
Trousselard, Marion; Lefebvre, Bertrand; Caillet, Lionel; Andruetan, Yann; de Montleau, Franck; Denis, Josiane; Canini, Frédéric
2016-07-30
An increased reactivity to the environment is observed in Post-Traumatic Stress Disorder (PTSD). It would be related to impairment of the Gamma Amino Butyric Acid (GABA) neurotransmission. The study aimed to evaluate plasma GABA concentration as a candidate for PTSD severity biomarker. This hypothesis was studied in 17 PTSD patients and 17 healthy Controls using classic and emotional Stroop paradigms. Plasma GABA concentrations were assessed before and after both Stroop tests to evaluate GABA basal tone and GABA reactivity (change in GABAp), respectively. During baseline, PTSD had lower plasma GABA concentrations than the Controls. After the Stroop conflicts GABA reactivity was also lower in PTSD than in the Controls. The GABA baseline tone was negatively correlated with the severity of the PTSD symptoms. This relation was only marginally observed for GABA reactivity. The results produced a trend due to the small size of the sample compared to the number of statistical results given. Altogether, the reduced GABA concentration observed in PTSD could be considered as a possible biomarker for PTSD severity. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Awotidebe, Taofeek O; Adedoyin, Rufus A; Afolabi, Mubaraq A; Opiyo, Rose
2016-01-01
Exercise plays significant role in the health outcomes of patients with diabetes, however, little is known about patients' knowledge of exercise for plasma blood glucose control among patients with type-2 diabetes (T2D). This study investigated knowledge, attitude and practice (KAP) of exercise for plasma blood glucose control among patients with T2D. This cross-sectional study recruited 299 patients with T2D (male=105; female=194) from selected government hospitals in Osun State, Nigeria using purposive sampling technique. Validated questionnaires were used to assess of exercise for plasma blood glucose control and socioeconomic status (SES) of the patients. Data were analysed using descriptive and inferential statistics. Alpha level was set at <0.05. The mean age of respondents was 51.9±9.8 years. A majority, 245(81.9%) were married individuals and more than half, 195(65.3%) were in the low SES. One hundred and forty-eight (49.5%) had good knowledge of exercise whilst 269(90.0%) had negative attitude to exercise practice. Less than a third, 82(27.4%) engaged in exercise practice for plasma blood glucose control. There was significant association between knowledge and practice of exercise ((2)=12.535; p=0.002). Furthermore, significant associations were found between knowledge and gender ((2)=11.453; p=0.003), and socioeconomic status ((2)=29.127, p=0.001) but not associated with attitude towards exercise (p>0.05). Patients with demonstrated good knowledge of exercise for plasma blood glucose control but reported negative attitude and poor practice of exercise. Copyright © 2016. Published by Elsevier Ltd.
Mueller matrix polarimetry on plasma sprayed thermal barrier coatings for porosity measurement.
Luo, David A; Barraza, Enrique T; Kudenov, Michael W
2017-12-10
Yttria-stabilized zirconia (YSZ) is the most widely used material for thermal plasma sprayed thermal barrier coatings (TBCs) used to protect gas turbine engine parts in demanding operation environments. The superior material properties of YSZ coatings are related to their internal porosity level. By quantifying the porosity level, tighter control on the spraying process can be achieved to produce reliable coatings. Currently, destructive measurement methods are widely used to measure the porosity level. In this paper, we describe a novel nondestructive approach that is applicable to classify the porosity level of plasma sprayed YSZ TBCs via Mueller matrix polarimetry. A rotating retarder Mueller matrix polarimeter was used to measure the polarization properties of the plasma sprayed YSZ coatings with different porosity levels. From these measurements, it was determined that a sample's measured depolarization ratio is dependent on the sample's surface roughness and porosity level. To this end, we correlate the depolarization ratio with the samples' surface roughness, as measured by a contact profilometer, as well as the total porosity level, in percentage measured using a micrograph and stereological analysis. With the use of this technique, a full-field and rapid measurement of porosity level can be achieved.
Gokbulut, Cengiz; Di Loria, Antonio; Gunay, Necati; Masucci, Roberto; Veneziano, Vincenzo
2011-12-01
To investigate plasma disposition, concentration in the hair, and anthelmintic efficacy of eprinomectin after topical administration in donkeys. 12 donkeys naturally infected with strongyle nematodes. The pour-on formulation of eprinomectin approved for use in cattle was administered topically to donkeys at a dosage of 0.5 mg/kg. Heparinized blood samples and hair samples were collected at various times between 1 hour and 40 days after administration. Samples were analyzed via high-performance liquid chromatography with fluorescence detection. Fecal strongyle egg counts were performed by use of a modified McMaster technique before and at weekly intervals for 8 weeks after treatment. Plasma concentration and systemic availability of eprinomectin were relatively higher in donkeys, compared with values reported for other animal species. Concerning the anthelmintic efficacy against strongyle nematodes, eprinomectin was completely effective (100%) on days 7 and 14 and highly effective (> 99%) until the end of the study at 56 days after treatment. No abnormal clinical signs or adverse reactions were observed for any donkeys after treatment. Eprinomectin had excellent safety. The relatively high plasma concentration after topical administration could result in use of eprinomectin for the control and treatment of parasitic diseases in donkeys.
Bekeschus, Sander; Schmidt, Anke; Kramer, Axel; Metelmann, Hans-Robert; Adler, Frank; von Woedtke, Thomas; Niessner, Felix; Weltmann, Klaus-Dieter; Wende, Kristian
2018-05-01
Promising cold physical plasma sources have been developed in the field of plasma medicine. An important prerequisite to their clinical use is lack of genotoxic effects in cells. During optimization of one or even different plasma sources for a specific application, large numbers of samples need to be analyzed. There are soft and easy-to-assess markers for genotoxic stress such as phosphorylation of histone H2AX (γH2AX) but only few tests are accredited by the OECD with regard to mutagenicity detection. The micronucleus (MN) assay is among them but often requires manual counting of many thousands of cells per sample under the microscope. A high-throughput MN assay is presented using image flow cytometry and image analysis software. A human lymphocyte cell line was treated with plasma generated with ten different feed gas conditions corresponding to distinct reactive species patterns that were investigated for their genotoxic potential. Several millions of cells were automatically analyzed by a MN quantification strategy outlined in detail in this work. Our data demonstrates the absence of newly formed MN in any feed gas condition using the atmospheric pressure plasma jet kINPen. As positive control, ionizing radiation gave a significant 5-fold increase in micronucleus frequency. Thus, this assay is suitable to assess the genotoxic potential in large sample sets of cells exposed chemical or physical agents including plasmas in an efficient, reliable, and semiautomated manner. Environ. Mol. Mutagen. 59:268-277, 2018. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.
Canisso, Igor F; Ball, Barry A; Scoggin, Kirsten E; Squires, Edward L; Williams, Neil M; Troedsson, Mats H
2015-03-01
The objectives of this study were to: (i) determine alpha-fetoprotein (AFP) concentrations in fetal fluids (FF), and (ii) compare plasma concentrations of AFP in mares with placentitis (n=17) and gestationally age-matched control mares (n=17). Fetal fluid sampling (FFS, n=7/group) was performed at 0, 5 and 12 days post inoculation (DPI) or until abortion. Plasma was harvested daily for 12 days or until abortion. Placentitis was induced via intracervical inoculation of Streptococcus equi ssp. zooepidemicus. Proteins present in the FF were resolved by 1D-SDS-PAGE, and immunoblotting was used to detect the presence of AFP in fetal fluids. Concentrations of AFP in FF and plasma were determined with a chemiluminescence immunoassay. Mixed models for DPI, and for days from abortion (DFA) were used to analyze plasma concentrations of AFP. A protein band ∼68kDa consistent with the AFP size was present in all samples of fetal fluids examined. Immunoblotting for AFP revealed a single protein band (∼68kDa) in all samples. Concentrations of AFP in FF appeared higher than those in maternal plasma. There were effects of time (DPI p<0.0001; DFA p=0.0002) and time-by-group interactions (DPI*Group p<0.06; Group*DFA p<0.001). This study confirmed that AFP is present in the FF of mares during the third trimester of pregnancy. Experimentally induced placentitis was associated with an elevation in maternal plasma concentrations of AFP. Copyright © 2015 Elsevier B.V. All rights reserved.
Konishi, H; Ichikawa, D; Komatsu, S; Shiozaki, A; Tsujiura, M; Takeshita, H; Morimura, R; Nagata, H; Arita, T; Kawaguchi, T; Hirashima, S; Fujiwara, H; Okamoto, K; Otsuji, E
2012-01-01
Background: Recently, it was reported that plasma microRNAs (miRNAs) are low-invasive useful biomarkers for cancer. We attempted to isolate gastric cancer (GC)-associated miRNAs comparing pre- and post-operative paired plasma, thereby excluding the possible effects of individual variability. Methods: This study was divided into four steps: (1) microarray analysis comparing pre- and post-operative plasma; (2) validation of candidate miRNAs by quantitative RT–PCR; (3) validation study of selected miRNAs using paired plasma; and (4) comparison of the levels of selected miRNAs in plasma between healthy controls and patients. Results: From the results of microarray analysis, nine candidate miRNAs the levels of which were markedly decreased in post-operative plasma were selected for further studies. After confirmation of their post-operative marked reduction, two candidate miRNAs, miR-451 and miR-486, were selected as plasma biomarkers, considering the abundance in plasma, and marked decrease in post-operative samples. In validation, the two miRNAs were found to decrease in post-operative plasma in 90 and 93% of patients (both P<0.01). In comparison with healthy controls, the levels of both miRNAs were found to be significantly higher in patients, and the area under the curve values were high at 0.96 and 0.92. Conclusion: Plasma miR-451 and miR-486 could be useful blood-based biomarkers for screening GC. PMID:22262318
Elmongy, Hatem; Ahmed, Hytham; Wahbi, Abdel-Aziz; Amini, Ahmad; Colmsjö, Anders; Abdel-Rehim, Mohamed
2016-08-01
A sensitive, accurate and reliable bioanalytical method for the enantioselective determination of metoprolol in plasma and saliva samples utilizing liquid chromatography-electrospray ionization tandem mass spectrometry was developed and validated. Human plasma and saliva samples were pretreated by microextraction by packed sorbent (MEPS) prior to analysis. A new MEPS syringe form with two inputs was used. Metoprolol enantiomers and internal standard pentycaine (IS) were eluted from MEPS sorbent using isopropanol after removal of matrix interferences using aliquots of 5% methanol in water. Complete separation of metoprolol enantiomers was achieved on a Cellulose-SB column (150 × 4.6 mm, 5 μm) using isocratic elution with mobile phase 0.1% ammonium hydroxide in hexane-isopropanol (80:20, v/v) with a flow rate of 0.8 mL/min. A post-column solvent-assisted ionization was applied to enhance metoprolol ionization signal in positive mode monitoring (+ES) using 0.5% formic acid in isopropanol at a flow rate of 0.2 mL/min. The total chromatographic run time was 10 min for each injection. The detection of metoprolol in plasma and saliva samples was performed using triple quadrupole tandem mass spectrometer in +ES under the following mass transitions: m/z 268.08 → 72.09 for metoprolol and m/z 303.3 → 154.3 for IS. The linearity range was 2.5-500 ng/mL for both R- and S-metoprolol in plasma and saliva. The limits of detection and quantitation for both enantiomers were 0.5 and 2.5 ng/mL respectively, in both matrices (plasma and saliva). The intra- and inter-day precisions were presented in terms of RSD values for replicate analysis of quality control samples and were <5%; the accuracy of determinations varied from 96 to 99%. The method was able to determine the therapeutic levels of metoprolol enantiomers in both human plasma and saliva samples successfully, which can aid in therapeutic drug monitoring in clinical laboratories. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Plasma heating for containerless and microgravity materials processing
NASA Technical Reports Server (NTRS)
Leung, Emily W. (Inventor); Man, Kin F. (Inventor)
1994-01-01
A method for plasma heating of levitated samples to be used in containerless microgravity processing is disclosed. A sample is levitated by electrostatic, electromagnetic, aerodynamic, or acoustic systems, as is appropriate for the physical properties of the particular sample. The sample is heated by a plasma torch at atmospheric pressure. A ground plate is provided to help direct the plasma towards the sample. In addition, Helmholtz coils are provided to produce a magnetic field that can be used to spiral the plasma around the sample. The plasma heating system is oriented such that it does not interfere with the levitation system.
An Atmospheric Pressure Plasma Setup to Investigate the Reactive Species Formation.
Gorbanev, Yury; Soriano, Robert; O'Connell, Deborah; Chechik, Victor
2016-11-03
Non-thermal atmospheric pressure ('cold') plasmas have received increased attention in recent years due to their significant biomedical potential. The reactions of cold plasma with the surrounding atmosphere yield a variety of reactive species, which can define its effectiveness. While efficient development of cold plasma therapy requires kinetic models, model benchmarking needs empirical data. Experimental studies of the source of reactive species detected in aqueous solutions exposed to plasma are still scarce. Biomedical plasma is often operated with He or Ar feed gas, and a specific interest lies in investigation of the reactive species generated by plasma with various gas admixtures (O2, N2, air, H2O vapor, etc.) Such investigations are very complex due to difficulties in controlling the ambient atmosphere in contact with the plasma effluent. In this work, we addressed common issues of 'high' voltage kHz frequency driven plasma jet experimental studies. A reactor was developed allowing the exclusion of ambient atmosphere from the plasma-liquid system. The system thus comprised the feed gas with admixtures and the components of the liquid sample. This controlled atmosphere allowed the investigation of the source of the reactive oxygen species induced in aqueous solutions by He-water vapor plasma. The use of isotopically labelled water allowed distinguishing between the species originating in the gas phase and those formed in the liquid. The plasma equipment was contained inside a Faraday cage to eliminate possible influence of any external field. The setup is versatile and can aid in further understanding the cold plasma-liquid interactions chemistry.
An Atmospheric Pressure Plasma Setup to Investigate the Reactive Species Formation
Gorbanev, Yury; Soriano, Robert; O'Connell, Deborah; Chechik, Victor
2016-01-01
Non-thermal atmospheric pressure ('cold') plasmas have received increased attention in recent years due to their significant biomedical potential. The reactions of cold plasma with the surrounding atmosphere yield a variety of reactive species, which can define its effectiveness. While efficient development of cold plasma therapy requires kinetic models, model benchmarking needs empirical data. Experimental studies of the source of reactive species detected in aqueous solutions exposed to plasma are still scarce. Biomedical plasma is often operated with He or Ar feed gas, and a specific interest lies in investigation of the reactive species generated by plasma with various gas admixtures (O2, N2, air, H2O vapor, etc.) Such investigations are very complex due to difficulties in controlling the ambient atmosphere in contact with the plasma effluent. In this work, we addressed common issues of 'high' voltage kHz frequency driven plasma jet experimental studies. A reactor was developed allowing the exclusion of ambient atmosphere from the plasma-liquid system. The system thus comprised the feed gas with admixtures and the components of the liquid sample. This controlled atmosphere allowed the investigation of the source of the reactive oxygen species induced in aqueous solutions by He-water vapor plasma. The use of isotopically labelled water allowed distinguishing between the species originating in the gas phase and those formed in the liquid. The plasma equipment was contained inside a Faraday cage to eliminate possible influence of any external field. The setup is versatile and can aid in further understanding the cold plasma-liquid interactions chemistry. PMID:27842375
2013-03-01
ratio ranges obtained for the six standards. Twelve samples were analyzed to demonstrate the efficiency of the extraction procedure. Drug and internal...frozen (−70 ◦C). Refrigerated samples were tested after 2 months of storage ; frozen samples were tested for up to 1 year from stor- age date. The...freeze–thaw stability was evaluated by analyzing three subject samples with known drug concentrations and two quality control samples at concentrations
Effect of capture stress on plasma enzyme activities in rainbow trout (Salmo gairdneri)
Bouck, G.R.; Cairns, M. A.; Christian, A. R.
1978-01-01
Four capture methods were used to collect domesticated rainbow trout (Salmo gairdneri): angling, electroshocking, seining, and direct netting (control). Blood was sampled rapidly upon capture, usually within 2 min. No significant differences were noted within the time frame of the experiment between the four capture groups for plasma protein concentration, lactate dehydrogenase activity, or leucine aminonaphthylamidase activity. Creatine phosphokinase activity was elevated among electroshocked fish. Acid phosphatase activity was too low for accurate measurement. Hematocrits were significantly elevated by capture struggles. These results indicate that these capture methods do not preclude the use of plasma enzyme levels for investigating the health of wild fish. Key words: plasma enzyme, capture stress, physiology, plasma protein, rainbow trout, lactate dehydrogenase, leucine aminonaphthylamidase, creatine phosphokinase
Degree of conversion of two lingual retainer adhesives cured with different light sources.
Usümez, Serdar; Büyükyilmaz, Tamer; Karaman, Ali Ihya; Gündüz, Beniz
2005-04-01
The aim of this study was to evaluate the degree of conversion (DC) of two lingual retainer adhesives, Transbond Lingual Retainer (TLR) and Light Cure Retainer (LCR), cured with a fast halogen light, a plasma arc light and a light-emitting diode (LED) at various curing times. A conventional halogen light served as the control. One hundred adhesive samples (five per group) were cured for 5, 10 or 15 seconds with an Optilux 501 (fast halogen light), for 3, 6 or 9 seconds with a Power Pac (plasma arc light), or for 10, 20 or 40 seconds with an Elipar Freelight (LED). Samples cured for 40 seconds with the conventional halogen lamp were used as the controls. Absorbance peaks were recorded using Fourier transform infrared (FT-IR) spectroscopy. DC values were calculated. Data were analysed using Kruskal-Wallis and Mann-Whitney U-tests. For the TLR, the highest DC values were achieved in 6 and 9 seconds with the plasma arc light. Curing with the fast halogen light for 15 seconds and with the LED for 40 seconds produced statistically similar DC values, but these were lower than those with the plasma arc light. All of these light exposures yielded a statistically significantly higher DC than 40 seconds of conventional halogen light curing. The highest DC value for the LCR was achieved in 15 seconds with the fast halogen light, then the plasma arc light curing for 6 seconds. These two combinations produced a statistically significantly higher DC when compared with the 40 seconds of conventional halogen light curing. The lowest DC for the LCR was achieved with 10 seconds of LED curing. The overall DC of the LCR was significantly higher than that of the TLR. The results suggest that a similar or higher DC than the control values could be achieved in 6-9 seconds by plasma arc curing, in 10-15 seconds by fast halogen curing or in 20 seconds by LED curing.
Hagman, Ragnvi; Stridsberg, Mats
2015-01-01
Objectives: Biomarkers representing sympathetic tone and the surgical stress response are measured to objectively evaluate surgical techniques and anaesthetic protocols. If a part of the intraoperative procedure is repeated on the contralateral organ, one animal may potentially serve as its own control and, if so, may minimize the problem of individual differences of the stress response to anaesthesia and surgery. This study aimed to investigate the use of chromogranin A for measurement of the intraoperative sympathetic tone. Additional aims were to investigate chromogranin A and cortisol as indicators of the intraoperative surgical stress response caused by repeated noxious stimuli in dogs subjected to ovariohysterectomy and thereby to investigate the possibility of one dog serving as its own control. Methods: Experiments were carried out on 10 dogs subjected to ovariohysterectomy. Perioperative blood samples (0–6) were collected after premedication, immediately before induction of anaesthesia (0), after induction of anaesthesia and before incision (1), before (2) and after (3) removal of the first ovary, after a 15-min pause before removal of the second ovary (4), after removal of the second ovary (5) and after closing the abdomen (6). Plasma chromogranin A and cortisol were analysed. Results: Plasma chromogranin A did not change. Plasma cortisol concentration did not change between before anaesthesia and opening of the abdomen. Plasma cortisol increased at removal of the first ovary. Cortisol did not change at removal of the second ovary but remained increased compared to initial sample. Conclusion: The results suggest chromogranin A is a poor indicator of intraoperative sympathetic tone during elective surgery in dogs. Cortisol measurement was useful for assessment of intraoperative noxious stimuli. However, at these test conditions, neither plasma chromogranin A nor plasma cortisol was useful for assessment of repeated intraoperative noxious stimuli where one dog served as its own control. PMID:26770773
Rattner, B.A.; Eastin, W.C.
1981-01-01
1. Blood samples were collected from mallard ducks after 6, 12, and 18 weeks of dietary exposure to mash containing 0.015%, 0.150%, and 1.500% crude oil.2. Plasma corticosterone concentrations in ducks fed mash containing 0.150% or 1.500% Alaskan Prudhoe Bay crude oil were uniformly depressed when compared to values in untreated control birds.3. Plasma thyroxine concentration was not altered in ducks chronically exposed to crude oil.4. The observed alteration in corticosterone concentration could reduce tolerance to temperature and dietary fluctuations in the environment.
Hormonal and electrolyte responses to acute isohemic volume expansion in unanesthetized rats
NASA Technical Reports Server (NTRS)
Chenault, V. M.; Morris, M.; Lynch, C. D.; Maultsby, S. J.; Hutchins, P. M.
1993-01-01
This study was undertaken to explore the time course of the metabolic response to isohemic blood volume expansion (30%) in normotensive, unanesthetized Sprague-Dawley rats. Whole blood, drawn from a femoral artery catheter of conscious donor rats, was infused into the jugular vein of recipient rats. Blood samples were drawn from a carotid artery of recipient rats at time points beginning immediately post-volume expansion (IPVE) up through 5 days post-volume expansion (PVE). To characterize the attendant compensatory mechanisms, the plasma concentrations of electrolytes and fluid regulatory hormones were determined. Hematocrit began to raise IPVE and was significantly elevated above control IPVE 20, 30, 40, 60, and 90 min, and 2, 4, 6, 8, 12, and 24 hr PVE. Consistent with our current understanding of the hormonal response to excess volume, atrial natriuretic factor was significantly increased above the prevolume expansion (control) values 0-30 min PVE. Surprisingly, plasma aldosterone levels were significantly increased above control at 20 and 30 min and 6 hr PVE, whereas plasma renin activity was significantly decreased 30-40 min PVE. Plasma sodium was not changed from control values except for a significant increase at 6 hr post-volume expansion. Plasma potassium, osmolality, and arginine vasopressin levels were not altered by the volume expansion. These studies delineate the physiologic time scheme operative in the regulation of fluid volume during acute ischemic volume expansion.
Monitoring genotoxic exposure in uranium miners
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sram, R.J.; Binkova, B.; Dobias, L.
1993-03-01
Recent data from deep uranium mines in Czechoslovakia indicated that in addition to radon daughter products, miners are also exposed to chemical mutagens. Mycotoxins were identified as a possible source of mutagenicity present in the mines. Various methods of biomonitoring were used to examine three groups of miners from different uranium mines. Cytogenetic analysis of peripheral lymphocytes, unscheduled DNA synthesis (UDS) in lymphocytes, and lipid peroxidation (LPO) in both plasma and lymphocytes were studied on 66 exposed miners and 56 controls. Throat swabs were taken from 116 miners and 78 controls. Significantly increased numbers of aberrant cells were found inmore » all groups of miners, as well as decreased UDS values in lymphocytes and increased LPO plasma levels in comparison to controls. Molds were detected in throat swabs from 27% of miners, and 58% of these molds were embryotoxic. Only 5% of the control samples contained molds and none of them was embryotoxic. The following mycotoxins were isolated from miners' throat swab samples: rugulosin, sterigmatocystin, mycophenolic acid, brevianamid A, citreoviridin, citrinin, penicilic acid, and secalonic acid. These data suggest that mycotoxins are a genotoxic factor affecting uranium miners.« less
Monitoring genotoxic exposure in uranium miners.
Srám, R J; Binková, B; Dobiás, L; Rössner, P; Topinka, J; Veselá, D; Veselý, D; Stejskalová, J; Bavorová, H; Rericha, V
1993-01-01
Recent data from deep uranium mines in Czechoslovakia indicated that in addition to radon daughter products, miners are also exposed to chemical mutagens. Mycotoxins were identified as a possible source of mutagenicity present in the mines. Various methods of biomonitoring were used to examine three groups of miners from different uranium mines. Cytogenetic analysis of peripheral lymphocytes, unscheduled DNA synthesis (UDS) in lymphocytes, and lipid peroxidation (LPO) in both plasma and lymphocytes were studied on 66 exposed miners and 56 controls. Throat swabs were taken from 116 miners and 78 controls. Significantly increased numbers of aberrant cells were found in all groups of miners, as well as decreased UDS values in lymphocytes and increased LPO plasma levels in comparison to controls. Molds were detected in throat swabs from 27% of miners, and 58% of these molds were embryotoxic. Only 5% of the control samples contained molds and none of them was embryotoxic. The following mycotoxins were isolated from miners' throat swab samples: rugulosin, sterigmatocystin, mycophenolic acid, brevianamid A, citreoviridin, citrinin, penicilic acid, and secalonic acid. These data suggest that mycotoxins are a genotoxic factor affecting uranium miners. PMID:8319649
Method of high-precision microsampled blood and plasma mass densitometry
NASA Technical Reports Server (NTRS)
Hinghofer-Szalkay, H.
1986-01-01
The reliability of the mechanical oscillator technique for blood and plasma density measurements on samples of volumes less than 0.1 ml is examined, and a precision of 0.001 g/l is found if plasma-isodensic heparin solution and siliconized densitometers are employed. Sources of measurement errors in the density determinations include storage of plasma samples, inhomogeneity of blood samples, and density reading before adequate temperature equilibration. In tests of plasma sample storage, the best reproducibility was obtained with samples kept at 4 C. Linear correlations were found between plasma density and plasma protein concentration, blood density and blood hemoglobin concentration, and erythrocyte density and MCHC.
Early Fluid and Protein Shifts in Men During Water Immersion
NASA Technical Reports Server (NTRS)
Hinghofer-Szalkay, H.; Harrison, M. H.; Greenleaf, J. E.
1987-01-01
High precision blood and plasma densitometry was used to measure transvascular fluid shifts during water immersion to the neck. Six men (28-49 years) undertook 30 min of standing immersion in water at 35.0 +/- 0.2 C; immersion was preceded by 30 min control standing in air at 28 +/- 1 C. Blood was sampled from an antecubital catheter for determination of Blood Density (BD), Plasma Density (PD), Haematocrit (Ht), total Plasma Protein Concentration (PPC), and Plasma Albumin Concentration (PAC). Compared to control, significant decreases (p less than 0.01) in all these measures were observed after 20 min immersion. At 30 min, plasma volume had increased by 11.0 +/- 2.8%; the average density of the fluid shifted from extravascular fluid into the vascular compartment was 1006.3 g/l; albumin moved with the fluid and its albumin concentration was about one-third of the plasma protein concentration during early immersion. These calculations are based on the assumption that the F-cell ratio remained unchanged. No changes in erythrocyte water content during immersion were found. Thus, immersion-induced haemodilution is probably accompanied by protein (mainly albumin) augmentation which accompanies the intra-vascular fluid shift.
Kleniewska, Paulina; Hoffmann, Arkadiusz; Pniewska, Ewa
2016-01-01
The aim of the present study was to assess whether probiotic bacteria Lactobacillus casei (4 × 108 CFU) influences the antioxidant properties of human plasma when combined with prebiotic Inulin (400 mg). Experiments were carried out on healthy volunteers (n = 32). Volunteers were divided according to sex (16 male and 16 female) and randomly assigned to synbiotic and control groups. Blood samples were collected before synbiotic supplementation and after 7 weeks, at the end of the study. Catalase (CAT), superoxide dismutase (SOD), glutathione peroxidase (GPx) activity, and the ferric reducing ability of plasma (FRAP) in human plasma were examined. The administration of synbiotics containing L. casei plus Inulin resulted in a significant increase in FRAP values (p = 0.00008) and CAT activity (p = 0.02) and an insignificant increase in SOD and GPx activity compared to controls. Synbiotics containing L. casei (4 × 108 CFU) with prebiotic Inulin (400 mg) may have a positive influence on human plasma antioxidant capacity and the activity of selected antioxidant enzymes. PMID:27066188
Assessments of plasma ghrelin levels in the early stages of parkinson's disease.
Song, Ning; Wang, Weiwei; Jia, Fengjv; Du, Xixun; Xie, Anmu; He, Qing; Shen, Xiaoli; Zhang, Jing; Rogers, Jack T; Xie, Junxia; Jiang, Hong
2017-10-01
Gastrointestinal symptoms are early events in Parkinson's disease (PD). The gastrointestinal hormone ghrelin was neuroprotective in the nigrostriatal dopamine system. The objective of this study was to assess ghrelin levels in the early stages of PD. Plasma was collected in the fasting state in 291 PD patients in stages 1-3 and 303 age- and sex-matched healthy controls. Additional samples were taken in the glucose response test to assess nutrition-related ghrelin levels in 20 PD patients and 20 healthy controls. The enzyme-linked immunosorbent assay was used to measure total and active plasma ghrelin levels. We reported that total and active plasma ghrelin levels were decreased in PD, although there was no difference across progressive PD stages. Postprandial ghrelin suppression and preprandial peak responses were both attenuated in PD. Plasma ghrelin levels were decreased in PD; however, this event might be irrelevant to PD progression. Ghrelin responses to meals were also impaired in PD. © 2017 International Parkinson and Movement Disorder Society. © 2017 International Parkinson and Movement Disorder Society.
Guan, Fuyu; Robinson, Mary A
2017-09-08
The ability to analyze biological samples for multitudinous exogenous peptides with a single analytical method is desired for doping control in horse racing. The key to achieving this goal is the capability of extracting all target peptides from the sample matrix. In the present study, theory of mixed-mode solid-phase extraction (SPE) of peptides from plasma is described, and a generic mixed-mode SPE procedure has been developed for recovering multitudinous exogenous peptides with remarkable sequence diversity, from equine plasma and urine in a single procedure. Both the theory and the developed SPE procedure have led to the development of a novel analytical method for comprehensive detection of multitudinous bioactive peptides in equine plasma and urine using liquid chromatography coupled to high resolution mass spectrometry (LC-HRMS). Thirty nine bioactive peptides were extracted with strong anion-exchange mixed-mode SPE sorbent, separated on a reversed-phase C 18 column and detected by HRMS and data-dependent tandem mass spectrometry. The limit of detection (LOD) was 10-50 pg mL -1 in plasma for most of the peptides and 100 pg mL -1 for the remaining. For urine, LOD was 20-400 pg mL -1 for most of the peptides and 1-4 ng mL -1 for the others. In vitro degradation of the peptides in equine plasma and urine was examined at ambient temperature; the peptides except those with a D-amino acid at position 2 were unstable not only in plasma but also in urine. The developed method was successful in analysis of plasma and urine samples from horses administered dermorphin. Additionally, dermorphin metabolites were identified in the absence of reference standards. The developed SPE procedure and LC-HRMS method can theoretically detect virtually all peptides present at a sufficient concentration in a sample. New peptides can be readily included in the method to be detected without method re-development. The developed method also generates such data that can be retrospectively analyzed for peptides unknown at the time of sample analysis. It is the first generic analytical method for comprehensive detection of multitudinous exogenous peptides in biological samples, to the authors' knowledge. Copyright © 2017 Elsevier B.V. All rights reserved.
The validation of the Z-Scan technique for the determination of plasma glucose
NASA Astrophysics Data System (ADS)
Alves, Sarah I.; Silva, Elaine A. O.; Costa, Simone S.; Sonego, Denise R. N.; Hallack, Maira L.; Coppini, Ornela L.; Rowies, Fernanda; Azzalis, Ligia A.; Junqueira, Virginia B. C.; Pereira, Edimar C.; Rocha, Katya C.; Fonseca, Fernando L. A.
2013-11-01
Glucose is the main energy source for the human body. The concentration of blood glucose is regulated by several hormones including both antagonists: insulin and glucagon. The quantification of glucose in the blood is used for diagnosing metabolic disorders of carbohydrates, such as diabetes, idiopathic hypoglycemia and pancreatic diseases. Currently, the methodology used for this determination is the enzymatic colorimetric with spectrophotometric. This study aimed to validate the use of measurements of nonlinear optical properties of plasma glucose via the Z-Scan technique. For this we used samples of calibrator patterns that simulate commercial samples of patients (ELITech ©). Besides calibrators, serum glucose levels within acceptable reference values (normal control serum - Brazilian Society of Clinical Pathology and Laboratory Medicine) and also overestimated (pathological control serum - Brazilian Society of Clinical Pathology and Laboratory Medicine) were used in the methodology proposal. Calibrator dilutions were performed and determined by the Z-Scan technique for the preparation of calibration curve. In conclusion, Z-Scan method can be used to determinate glucose levels in biological samples with enzymatic colorimetric reaction and also to apply the same quality control parameters used in biochemistry clinical.
Detection of Parvovirus B19 Infection in Thalasemic Patients in Isfahan Province, Iran
Nikoozad, Razieh; Mahzounieh, Mohammad Reza; Ghorani, Mohammad Reza
2015-01-01
Background: Parvovirus B19, a member of the Erythrovirus genus of Parvoviridae family, causes various clinical illnesses including infectious erythema, arthropathy, hydrops fetalis or congenital anemia, and transient aplastic crises. The B19 virus can be transmitted through respiratory secretions, blood products, and blood transfusion. Objectives: The aim of this study was to detect the B19 virus in thalassemia patients in Isfahan, Iran. Patients and Methods: The prevalence of parvovirus B19 infection was compared between thalassemia major patients and healthy subjects. Plasma samples were collected from 30 thalassemia patients from Isfahan, Iran. Thirty patients without any blood complications were considered as the control group. After DNA extraction from the plasma samples, polymerase chain reaction was performed for parvovirus B19 detection. Results: The parvovirus B19-specific nucleotide sequence was detected in 6 patients (20%). None of the samples obtained from the 30 control subjects tested positive for B19. Conclusions: In this study B19-Parvovirus infection were detected in patients with hematologic disorders in comparison with control subjects. Screening of patients with a high risk of parvovirus B19 infection can considerably reduce the incidence and prevalence of B19 infection. PMID:26855745
Detection of Parvovirus B19 Infection in Thalasemic Patients in Isfahan Province, Iran.
Nikoozad, Razieh; Mahzounieh, Mohammad Reza; Ghorani, Mohammad Reza
2015-11-01
Parvovirus B19, a member of the Erythrovirus genus of Parvoviridae family, causes various clinical illnesses including infectious erythema, arthropathy, hydrops fetalis or congenital anemia, and transient aplastic crises. The B19 virus can be transmitted through respiratory secretions, blood products, and blood transfusion. The aim of this study was to detect the B19 virus in thalassemia patients in Isfahan, Iran. The prevalence of parvovirus B19 infection was compared between thalassemia major patients and healthy subjects. Plasma samples were collected from 30 thalassemia patients from Isfahan, Iran. Thirty patients without any blood complications were considered as the control group. After DNA extraction from the plasma samples, polymerase chain reaction was performed for parvovirus B19 detection. The parvovirus B19-specific nucleotide sequence was detected in 6 patients (20%). None of the samples obtained from the 30 control subjects tested positive for B19. In this study B19-Parvovirus infection were detected in patients with hematologic disorders in comparison with control subjects. Screening of patients with a high risk of parvovirus B19 infection can considerably reduce the incidence and prevalence of B19 infection.
Alain, S; Lachaise, V; Hantz, S; Denis, F
2010-04-01
The broad use of cytomegalovirus (CMV) viral load quantification in blood to follow immunosuppressed patients need standardized assays. Choice of whole blood allows follow-up for several viruses and simplifies pretreatment and storage of samples. We therefore evaluated the LightCycler CMV Quant Kit (Roche Diagnostics) assay on whole blood after a manual extraction (High Pure viral nucleic acid kit, Roche Diagnostics), using as a reference an in-house Taqman assay (LC1UL83) which has been validated in various clinical situations. A panel obtained by serial dilutions of a virion stock in CMV whole blood, a commercial plasma quality control (VQC, Argène, France) crude or diluted in whole blood, infected cells extracts and 46 clinical samples from transplanted patients were tested simultaneously by both techniques. For plasma quality controls, both PCR assays are correlated VQC (R(2)=0.93). On whole blood or infected cells dilutions, correlation shows an overestimation by the LC1UL83 assay (mean 1.2 log copies/ml) over 3 log though R(2)=0.94. Results with CMV Quant Kit are closer to expected values. Results on clinical samples are close to quality controls with a lower variation of quantification (0.76 log copies/ml). CMV Quant Kit performs well when compared with a clinically validated PCR. Quality control results showed discrepancies between plasma and whole blood, demonstrating the need for whole blood standardized panels to compare the methods. This underlines the need to follow a patient with the same technique during his follow-up. Copyright 2009 Elsevier Masson SAS. All rights reserved.
Price, Richard W; Parham, Robin; Lu, Jing; Wring, Stephen A.; Baker, Brian; Sailstad, Jeff; Hoh, Rebecca; Liegler, Teri; Spudich, Serena; Kuritzkes, Daniel R; Deeks, Steven G
2009-01-01
Background Enfuvirtide is a potent inhibitor of systemic HIV-1 replication, but its penetration into the human central nervous system (CNS) has not been analyzed. Here, we define cerebrospinal fluid (CSF) enfuvirtide pharmacokinetics and present a case illustrating the use of enfuvirtide as a probe to trace the origins of CSF HIV-1 quasispecies. Methods Enfuvirtide CSF PK was assessed in 18 CSF and plasma sample pairs from 4 HIV-1-infected subjects. Enfuvirtide levels were measured by liquid chromatography tandem mass spectrometry using known standards and controls that including spiked CSF samples from untreated, HIV-negative subjects. A segment of the gp41-coding region encompassing the heptad repeat (HR)-1 and HR-2 domains was amplified from selected CSF and plasma samples, and independent clones sequenced to assess resistance-associated mutations. Results CSF and plasma samples obtained between 2 and 20 hrs after enfuvirtide injection showed plasma concentrations similar to previous reports (mean 3.687 +/−1.828 µg/ml SD) with prolonged decay. By contrast, enfuvirtide in all CSF samples was below the assay detection limit of 0.025 µg/ml. In one subject, who developed a transient increase in CSF HIV-1 RNA, 7 of 7 CSF and plasma clones had identical enfuvirtide resistance-associated V38A mutation, suggesting that the CSF quasispecies derived from that of blood. Conclusions Enfuvirtide CSF penetration into CSF is negligible, and thus in clinical settings where direct CNS drug exposure is critical, this drug will likely not directly contribute to the local therapeutic effect. Enfuvirtide can be used as a tool to dissect the origin of the CNS virus. PMID:18572749
Bhatt, Mitesh; Shah, Sanjay
2010-11-01
A method based on ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) in combination with solid-phase extraction for sample pretreatment has been developed for the simultaneous analysis of amitriptyline and its main metabolite in human plasma. The extraction of the analytes from plasma samples was carried out by means of a selective SPE procedure using hydrophilic-lipophilic balance cartridges. The assay involves a simple solid-phase extraction (SPE) procedure of 0.2 mL of human plasma and analysis was performed on a triple-quadrupole tandem mass spectrometer by multiple reactions monitoring (MRM) mode via electrospray ionization (ESI). The standard calibration curve was linear over the ranges 0.370-95.539 ng/mL for amitriptyline and 0.365-94.374 ng/mL for nortriptyline, expressed by the linear correlation coefficient r², which was better than 0.995 for both. The intra- and inter-day precision and accuracy of the quality control samples were within 10.0%. The recovery was 85.3, 88.4 and 80.7% for amitriptyline, nortriptyline and doxepin respectively. Total run time was 1.2 min only for each sample, which makes it possible to analyze more than 400 samples per day. The method was highly reproducible and gave peaks with excellent chromatography properties. Copyright © 2010 John Wiley & Sons, Ltd.
Ondigo, Bartholomew N; Park, Gregory S; Gose, Severin O; Ho, Benjamin M; Ochola, Lyticia A; Ayodo, George O; Ofulla, Ayub V; John, Chandy C
2012-12-21
Multiplex cytometric bead assay (CBA) have a number of advantages over ELISA for antibody testing, but little information is available on standardization and validation of antibody CBA to multiple Plasmodium falciparum antigens. The present study was set to determine optimal parameters for multiplex testing of antibodies to P. falciparum antigens, and to compare results of multiplex CBA to ELISA. Antibodies to ten recombinant P. falciparum antigens were measured by CBA and ELISA in samples from 30 individuals from a malaria endemic area of Kenya and compared to known positive and negative control plasma samples. Optimal antigen amounts, monoplex vs multiplex testing, plasma dilution, optimal buffer, number of beads required were assessed for CBA testing, and results from CBA vs. ELISA testing were compared. Optimal amounts for CBA antibody testing differed according to antigen. Results for monoplex CBA testing correlated strongly with multiplex testing for all antigens (r = 0.88-0.99, P values from <0.0001 - 0.004), and antibodies to variants of the same antigen were accurately distinguished within a multiplex reaction. Plasma dilutions of 1:100 or 1:200 were optimal for all antigens for CBA testing. Plasma diluted in a buffer containing 0.05% sodium azide, 0.5% polyvinylalcohol, and 0.8% polyvinylpyrrolidone had the lowest background activity. CBA median fluorescence intensity (MFI) values with 1,000 antigen-conjugated beads/well did not differ significantly from MFI with 5,000 beads/well. CBA and ELISA results correlated well for all antigens except apical membrane antigen-1 (AMA-1). CBA testing produced a greater range of values in samples from malaria endemic areas and less background reactivity for blank samples than ELISA. With optimization, CBA may be the preferred method of testing for antibodies to P. falciparum antigens, as CBA can test for antibodies to multiple recombinant antigens from a single plasma sample and produces a greater range of values in positive samples and lower background readings for blank samples than ELISA.
Musfeld, C; Biollaz, J; Bélaz, N; Kesselring, U W; Decosterd, L A
2001-01-01
N1-Methylnicotinamide (NMN) is an endogenous cationic metabolite of nicotinamide (niacine, vitamine PP) whose renal clearance reflects both the capacity of the renal tubular transport system to secrete organic cations and renal plasma flow. NMN is present in human plasma and urine at the 1-117-ng ml(-1) and 0.5-25-microg ml(-1) concentration range, respectively, and its level depends notably on pathophysiological (age, renal or hepatic diseases) conditions. We report the optimization and validation of an HPLC method for the measurement of endogenous NMN in biological fluids after derivatization into a fluorescent compound. Plasma is first deproteinized with TCA 20% and the urine diluted 1:10 with HCI 10(-4) M prior to the derivatization procedure, which includes a condensation reaction of NMN with acetophenone in NaOH at 0 degrees C, followed by dehydration in formic acid and subsequent formation of the fluorescent 1,6-naphthyridine derivatives after heating samples in a boiling water bath. The synthetic homologous derivative N1-ethylnicotinamide (NEN) reacts similarly and is added as internal standard into the biological fluid. The reaction mixture is subjected to reverse phase high performance liquid chromatography on a Nucleosil 100-C18 column using a mobile phase (acetonitrile 22%, triethylamine 0.5%, 0.01 M sodium heptanesulfonate adjusted to pH 3.2), delivered isocratically at a flow rate of 1 ml min(-1), NMN and NEN are detected at 7.8 and 10 min by spectrofluorimetry with excitation and emission wavelengths set at 366 and 418 nm, respectively. The addition-calibration method is used with plasma and urine pools. Calibration curves (using the internal standard method) are linear (r2 > 0.997) at concentrations up to 109 ng ml(-1) and 15.7 microg ml(-1) in plasma and urine, respectively. Both intra- and inter-assay precision of plasma control samples at 10, 50 and 90 ng ml(-1) were lower than 3.3% and concentrations not deviating more than 2.7% from their nominal values. In urine intra- and inter-assay CVs of control samples at 1, 5 and 9 microg ml(-1) are lower than 8.3%, with concentrations not deviating more than -9.0 to +11.8% from their nominal values. This analytical method has therefore the required sensitivity and selectivity to measure NMN in plasma and urine, enabling the non-invasive determination of the tubular secretory capacity of the kidney and the renal plasma flow.
Sixteen-Day Bedrest Significantly Increases Plasma Colloid Osmotic Pressure
NASA Technical Reports Server (NTRS)
Hargens, Alan R.; Hsieh, S. T.; Murthy, G.; Ballard, R. E.; Convertino, V. A.; Wade, Charles E. (Technical Monitor)
1994-01-01
Upon exposure to microgravity, astronauts lose up to 10% of their total plasma volume, which may contribute to orthostatic intolerance after space flight. Because plasma colloid osmotic pressure (COP) is a primary factor maintaining plasma volume, our objective was to measure time course changes in COP during microgravity simulated by 6 deg. head-down tilt (HDT). Seven healthy male subjects (30-55 years of age) were placed in HDT for 16 days. For the purpose of another study, three of the seven subjects were chosen to exercise on a cycle ergometer on day 16. Blood samples were drawn immediately before bedrest on day 14 of bedrest, 18-24 hours following exercise while all subjects were still in HDT and 1 hour following bedrest termination. Plasma COP was measured in all 20 microliter EDTA-treated samples using an osmometer fitted with a PM 30 membrane. Data were analyzed with paired and unpaired t-tests. Plasma COP on day 14 of bedrest (29.9 +/- 0.69 mmHg) was significantly higher (p less than 0.005) than the control, pre-bedrest value (23.1 +/- 0.76 mmHg). At one hour of upright recovery after HDT, plasma COP remained significantly elevated (exercise: 26.9 +/- 0.87 mmHg; no exercise: 26.3 +/- 0.85 mmHg). Additionally, exercise had no significant effect on plasma COP 18-24 hours following exercise (exercise: 27.8 +/- 1.09 mmHg; no exercise: 27.1 +/- 0.78 mmHg). Our results demonstrate that plasma COP increases significantly with microgravity simulated by HDT. However, preliminary results indicate exercise during HDT does not significantly affect plasma COP.
Effects of plasma transfusions on antithrombin levels after paediatric liver transplantation.
Arni, D; Wildhaber, B E; McLin, V; Rimensberger, P C; Ansari, M; Fontana, P; Karam, O
2018-05-15
Thrombotic complications affect 3-10% of patients after liver transplantation (LT), leading to potentially life-threatening complications. In the days following LT, antithrombin (AT) is decreased longer than pro-coagulant factors, thus favouring a pro-thrombotic profile. Plasma transfusions are given empirically in some centres to correct AT levels following LT. We assessed the effect of plasma transfusion on AT levels after paediatric LT. Prospective single-centre observational study in 20 consecutive paediatric LT recipients over a 24-month period. Plasma was administered twice daily (10 ml/kg/dose) according to an existing protocol. AT levels were measured once daily, immediately prior to and one hour after the morning plasma transfusion. Sample size was calculated based on a non-inferiority hypothesis. The median age and weight were 11.6 years (IQR 2.8; 14.7) and 40 kg (IQR 12.75; 44.8), respectively. We collected 85-paired blood samples. The median AT level prior to plasma transfusion was 58%. The median difference in AT levels before and after plasma transfusion was 4.2% (P = 0.001). Changes in AT levels after plasma transfusion were not correlated with baseline AT levels (R = 0.19) or patient weight (R = 0.18). Plasma transfusions only marginally increase AT levels in children after LT. Therefore, prophylactic plasma transfusions probably do not seem to confer an advantage in the routine management of paediatric LT patients. Randomized controlled trials are needed to identify the optimal anticoagulation strategy in this specific population. © 2018 International Society of Blood Transfusion.
Ameling, Sabine; Kacprowski, Tim; Chilukoti, Ravi Kumar; Malsch, Carolin; Liebscher, Volkmar; Suhre, Karsten; Pietzner, Maik; Friedrich, Nele; Homuth, Georg; Hammer, Elke; Völker, Uwe
2015-10-14
Non-cellular blood circulating microRNAs (plasma miRNAs) represent a promising source for the development of prognostic and diagnostic tools owing to their minimally invasive sampling, high stability, and simple quantification by standard techniques such as RT-qPCR. So far, the majority of association studies involving plasma miRNAs were disease-specific case-control analyses. In contrast, in the present study, plasma miRNAs were analysed in a sample of 372 individuals from a population-based cohort study, the Study of Health in Pomerania (SHIP). Quantification of miRNA levels was performed by RT-qPCR using the Exiqon Serum/Plasma Focus microRNA PCR Panel V3.M covering 179 different miRNAs. Of these, 155 were included in our analyses after quality-control. Associations between plasma miRNAs and the phenotypes age, body mass index (BMI), and sex were assessed via a two-step linear regression approach per miRNA. The first step regressed out the technical parameters and the second step determined the remaining associations between the respective plasma miRNA and the phenotypes of interest. After regressing out technical parameters and adjusting for the respective other two phenotypes, 7, 15, and 35 plasma miRNAs were significantly (q < 0.05) associated with age, BMI, and sex, respectively. Additional adjustment for the blood cell parameters identified 12 and 19 miRNAs to be significantly associated with age and BMI, respectively. Most of the BMI-associated miRNAs likely originate from liver. Sex-associated differences in miRNA levels were largely determined by differences in blood cell parameters. Thus, only 7 as compared to originally 35 sex-associated miRNAs displayed sex-specific differences after adjustment for blood cell parameters. These findings emphasize that circulating miRNAs are strongly impacted by age, BMI, and sex. Hence, these parameters should be considered as covariates in association studies based on plasma miRNA levels. The established experimental and computational workflow can now be used in future screening studies to determine associations of plasma miRNAs with defined disease phenotypes.
Sivak, Olena; Darlington, Jerry; Gershkovich, Pavel; Constantinides, Panayiotis P; Wasan, Kishor M
2009-01-01
The aim of this work was to assess the effect of chronic administration of protonated nanostructured aluminosilicate (NSAS) on the plasma cholesterol levels and development of atherosclerotic lesions in Apolipoprotein (ApoE) deficient mice fed a high cholesterol and high fat diet. Apolipoprotein E (ApoE) deficient mice were divided into the following treatment groups: protonated NSAS 1.4% (w/w), untreated control and 2% (w/w) stigmastanol mixed with high-cholesterol/high-fat diet. Animals were treated for 12 weeks, blood samples were withdrawn every 4 weeks for determination of plasma cholesterol and triglyceride levels. At the end of the study the aortic roots were harvested for assessment of atherosclerotic lesions. NSAS at 1.4% (w/w) and stigmastanol at 2% (w/w) treatment groups showed significant decreases in plasma cholesterol concentrations at all time points relative to the control animals. The lesion sum area in 1.4% (w/w) NSAS and 2% (w/w) stigmastanol groups were significantly less from the control animals. In conclusion, in this study, the effectiveness of chronic administration of protonated NSAS material in the reduction of plasma cholesterol levels and decrease in development of atherosclerotic lesions was demonstrated in Apo-E deficient mice model. PMID:19638223
Sivak, Olena; Darlington, Jerry; Gershkovich, Pavel; Constantinides, Panayiotis P; Wasan, Kishor M
2009-07-28
The aim of this work was to assess the effect of chronic administration of protonated nanostructured aluminosilicate (NSAS) on the plasma cholesterol levels and development of atherosclerotic lesions in Apolipoprotein (ApoE) deficient mice fed a high cholesterol and high fat diet. Apolipoprotein E (ApoE) deficient mice were divided into the following treatment groups: protonated NSAS 1.4% (w/w), untreated control and 2% (w/w) stigmastanol mixed with high-cholesterol/high-fat diet. Animals were treated for 12 weeks, blood samples were withdrawn every 4 weeks for determination of plasma cholesterol and triglyceride levels. At the end of the study the aortic roots were harvested for assessment of atherosclerotic lesions. NSAS at 1.4% (w/w) and stigmastanol at 2% (w/w) treatment groups showed significant decreases in plasma cholesterol concentrations at all time points relative to the control animals. The lesion sum area in 1.4% (w/w) NSAS and 2% (w/w) stigmastanol groups were significantly less from the control animals. In conclusion, in this study, the effectiveness of chronic administration of protonated NSAS material in the reduction of plasma cholesterol levels and decrease in development of atherosclerotic lesions was demonstrated in Apo-E deficient mice model.
IL8 and IL16 levels indicate serum and plasma quality.
Kofanova, Olga; Henry, Estelle; Quesada, Rocio Aguilar; Bulla, Alexandre; Linares, Hector Navarro; Lescuyer, Pierre; Shea, Kathi; Stone, Mars; Tybring, Gunnel; Bellora, Camille; Betsou, Fay
2018-02-09
Longer pre-centrifugation times alter the quality of serum and plasma samples. Markers for such delays in sample processing and hence for the sample quality, have been identified. Twenty cytokines in serum, EDTA plasma and citrate plasma samples were screened for changes in concentration induced by extended blood pre-centrifugation delays at room temperature. The two cytokines that showed the largest changes were further validated for their "diagnostic performance" in identifying serum or plasma samples with extended pre-centrifugation times. In this study, using R&D Systems ELISA kits, EDTA plasma samples and serum samples with a pre-centrifugation delay longer than 24 h had an IL16 concentration higher than 313 pg/mL, and an IL8 concentration higher than 125 pg/mL, respectively. EDTA plasma samples with a pre-centrifugation delay longer than 48 h had an IL16 concentration higher than 897 pg/mL, citrate plasma samples had an IL8 concentration higher than 21.5 pg/mL and serum samples had an IL8 concentration higher than 528 pg/mL. These robust and accurate tools, based on simple and commercially available ELISA assays can greatly facilitate qualification of serum and plasma legacy collections with undocumented pre-analytics.
2012-01-01
Background Since betaine is an osmolyte and methyl donor, and abnormal betaine loss is common in diabetes mellitus (>20% patients), we investigated the relationship between betaine and the post-methionine load rise in homocysteine, in diabetes and control subjects. The post-methionine load test is reported to be both an independent vascular risk factor and a measure of betaine sufficiency. Methods Patients with type 2 diabetes (n = 34) and control subjects (n = 17) were recruited. We measured baseline fasting plasma and 4-hour post-methionine load (L-methionine, 0.1 mg/kg body weight) concentrations of homocysteine, betaine, and the betaine metabolite N,N-dimethylglycine. Baseline urine excretions of betaine, dimethylglycine and glucose were measured on morning urine samples as the ratio to urine creatinine. Statistical determinants of the post-methionine load increase in homocysteine were identified in multiple linear regression models. Results Plasma betaine concentrations and urinary betaine excretions were significantly (p < 0.001) more variable in the subjects with diabetes compared with the controls. Dimethylglycine excretion (p = 0.00014) and plasma dimethylglycine concentrations (p = 0.039) were also more variable. In diabetes, plasma betaine was a significant negative determinant (p < 0.001) of the post-methionine load increase in homocysteine. However, it was not conclusive that this was different from the relationship in the controls. In the patients with diabetes, a strong relationship was found between urinary betaine excretion and urinary glucose excretion (but not with plasma glucose). Conclusions Both high and low plasma betaine concentrations, and high and low urinary betaine excretions, are more prevalent in diabetes. The availability of betaine affects the response in the methionine load test. The benefits of increasing betaine intake should be investigated. PMID:22510294
Characterization and classification of lupus patients based on plasma thermograms
Chaires, Jonathan B.; Mekmaysy, Chongkham S.; DeLeeuw, Lynn; Sivils, Kathy L.; Harley, John B.; Rovin, Brad H.; Kulasekera, K. B.; Jarjour, Wael N.
2017-01-01
Objective Plasma thermograms (thermal stability profiles of blood plasma) are being utilized as a new diagnostic approach for clinical assessment. In this study, we investigated the ability of plasma thermograms to classify systemic lupus erythematosus (SLE) patients versus non SLE controls using a sample of 300 SLE and 300 control subjects from the Lupus Family Registry and Repository. Additionally, we evaluated the heterogeneity of thermograms along age, sex, ethnicity, concurrent health conditions and SLE diagnostic criteria. Methods Thermograms were visualized graphically for important differences between covariates and summarized using various measures. A modified linear discriminant analysis was used to segregate SLE versus control subjects on the basis of the thermograms. Classification accuracy was measured based on multiple training/test splits of the data and compared to classification based on SLE serological markers. Results Median sensitivity, specificity, and overall accuracy based on classification using plasma thermograms was 86%, 83%, and 84% compared to 78%, 95%, and 86% based on a combination of five antibody tests. Combining thermogram and serology information together improved sensitivity from 78% to 86% and overall accuracy from 86% to 89% relative to serology alone. Predictive accuracy of thermograms for distinguishing SLE and osteoarthritis / rheumatoid arthritis patients was comparable. Both gender and anemia significantly interacted with disease status for plasma thermograms (p<0.001), with greater separation between SLE and control thermograms for females relative to males and for patients with anemia relative to patients without anemia. Conclusion Plasma thermograms constitute an additional biomarker which may help improve diagnosis of SLE patients, particularly when coupled with standard diagnostic testing. Differences in thermograms according to patient sex, ethnicity, clinical and environmental factors are important considerations for application of thermograms in a clinical setting. PMID:29149219
Kowalczyk-Zieba, I; Woclawek-Potocka, I; Piskula, M K; Piotrowska-Tomala, K K; Boruszewska, D; Bah, M M; Siemieniuch, M J; Skarzynski, D J
2011-12-01
The present study compared the changes in isoflavone (daidzein and genistein) and their metabolite (equol and para-ethyl-phenol) concentrations in the blood plasma of cows with induced mastitis and metritis after feeding with soy bean. Sixteen cows were divided into four groups: control for mastitis group, cows with induced mastitis group, control for metritis group, and cows with induced metritis group. All cows were fed a single dose of 2.5 kg of soy bean and then blood samples were taken from the jugular vein for 8 h at predetermined intervals. The concentrations of soy bean-derived isoflavones and their active metabolites were measured in the blood plasma on HPLC system. β-Glucuronidase activity in the blood plasma of cows was measured by fluorometric method. In the blood plasma of cows with induced mastitis and metritis, we found considerably higher concentrations and time-dependent increase in isoflavone metabolites (equol and para-ethyl-phenol) with reference to cyclic cows (P < 0.05). Moreover, we noticed significant decrease of genistein in the blood plasma of the cows with induced metritis compared with control cows (P < 0.05). In addition, in the blood plasma of the cows with induced metritis, we found an increase in β-glucuronidase activity compared with control cows (P < 0.05). In conclusion, health status of the females influenced the concentrations of isoflavone metabolites in the blood plasma of the cows. Experimentally induced mastitis and metritis increased isoflavone absorption, biotransformation and metabolism. Therefore, we suggest that cows with induced mastitis and metritis are more exposed to active isoflavone metabolite actions than healthy cows. Copyright © 2011. Published by Elsevier Inc.
Cooper, Jason D.; Tomasik, Jakub; Bahn, Sabine; Aerts, Joeri L.; Osterhaus, Albert D. M. E.; Gruters, Rob A.; Andeweg, Arno C.
2018-01-01
Objectives To characterize the host response to dendritic cell-based immunotherapy and subsequent combined antiretroviral therapy (cART) interruption in HIV-1-infected individuals at the plasma protein level. Design An autologous dendritic cell (DC) therapeutic vaccine was administered to HIV-infected individuals, stable on cART. The effect of vaccination was evaluated at the plasma protein level during the period preceding cART interruption, during analytical therapy interruption and at viral reactivation. Healthy controls and post-exposure prophylactically treated healthy individuals were included as controls. Methods Plasma marker (‘analyte’) levels including cytokines, chemokines, growth factors, and hormones were measured in trial participants and control plasma samples using a multiplex immunoassay. Analyte levels were analysed using principle component analysis, cluster analysis and limma. Blood neutrophil counts were analysed using linear regression. Results Plasma analyte levels of HIV-infected individuals are markedly different from those of healthy controls and HIV-negative individuals receiving post-exposure prophylaxis. Viral reactivation following cART interruption also affects multiple analytes, but cART interruption itself only has only a minor effect. We find that Thyroxine-Binding Globulin (TBG) levels and late-stage neutrophil numbers correlate with the time off cART after DC vaccination. Furthermore, analysis shows that cART alters several regulators of blood glucose levels, including C-peptide, chromogranin-A and leptin. HIV reactivation is associated with the upregulation of CXCR3 ligands. Conclusions Chronic HIV infection leads to a change in multiple plasma analyte levels, as does virus reactivation after cART interruption. Furthermore, we find evidence for the involvement of TBG and neutrophils in the response to DC-vaccination in the setting of HIV-infection. PMID:29389978
van den Ham, Henk-Jan; Cooper, Jason D; Tomasik, Jakub; Bahn, Sabine; Aerts, Joeri L; Osterhaus, Albert D M E; Gruters, Rob A; Andeweg, Arno C
2018-01-01
To characterize the host response to dendritic cell-based immunotherapy and subsequent combined antiretroviral therapy (cART) interruption in HIV-1-infected individuals at the plasma protein level. An autologous dendritic cell (DC) therapeutic vaccine was administered to HIV-infected individuals, stable on cART. The effect of vaccination was evaluated at the plasma protein level during the period preceding cART interruption, during analytical therapy interruption and at viral reactivation. Healthy controls and post-exposure prophylactically treated healthy individuals were included as controls. Plasma marker ('analyte') levels including cytokines, chemokines, growth factors, and hormones were measured in trial participants and control plasma samples using a multiplex immunoassay. Analyte levels were analysed using principle component analysis, cluster analysis and limma. Blood neutrophil counts were analysed using linear regression. Plasma analyte levels of HIV-infected individuals are markedly different from those of healthy controls and HIV-negative individuals receiving post-exposure prophylaxis. Viral reactivation following cART interruption also affects multiple analytes, but cART interruption itself only has only a minor effect. We find that Thyroxine-Binding Globulin (TBG) levels and late-stage neutrophil numbers correlate with the time off cART after DC vaccination. Furthermore, analysis shows that cART alters several regulators of blood glucose levels, including C-peptide, chromogranin-A and leptin. HIV reactivation is associated with the upregulation of CXCR3 ligands. Chronic HIV infection leads to a change in multiple plasma analyte levels, as does virus reactivation after cART interruption. Furthermore, we find evidence for the involvement of TBG and neutrophils in the response to DC-vaccination in the setting of HIV-infection.
Analysis of GaN Damage Induced by Cl2/SiCl4/Ar Plasma
NASA Astrophysics Data System (ADS)
Minami, Masaki; Tomiya, Shigetaka; Ishikawa, Kenji; Matsumoto, Ryosuke; Chen, Shang; Fukasawa, Masanaga; Uesawa, Fumikatsu; Sekine, Makoto; Hori, Masaru; Tatsumi, Tetsuya
2011-08-01
GaN-based optical devices are fabricated using a GaN/InGaN/GaN sandwiched structure. The effect of radicals, ions, and UV light on the GaN optical properties during Cl2/SiCl4/Ar plasma etching was evaluated using photoluminescence (PL) analysis. The samples were exposed to plasma (radicals, ions, and UV light) using an inductively coupled plasma (ICP) etching system and a plasma ion beam apparatus that can separate the effects of UV and ions both with and without covering the SiO2 window on the surface. Etching damage in an InGaN single quantum well (SQW) was formed by exposing the sample to plasma. The damage, which decreases PL emission intensity, was generated not only by ion beam irradiation but also by UV light irradiation. PL intensity decreased when the thickness of the upper GaN layer was etched to less than 60 nm. In addition, simultaneous irradiation of UV light and ions slightly increased the degree of damage. There seems to be a synergistic effect between the UV light and the ions. For high-quality GaN-based optoelectronics and power devices, UV light must be controlled during etching processes in addition to the etching profile, selectivity, and ion bombardment damage.
Prior, Ronald L; Hoang, Ha; Gu, Liwei; Wu, Xianli; Bacchiocca, Mara; Howard, Luke; Hampsch-Woodill, Maureen; Huang, Dejian; Ou, Boxin; Jacob, Robert
2003-05-21
Methods are described for the extraction and analysis of hydrophilic and lipophilic antioxidants, using modifications of the oxygen radical absorbing capacity (ORAC(FL)) procedure. These methods provide, for the first time, the ability to obtain a measure of "total antioxidant capacity" in the protein free plasma, using the same peroxyl radical generator for both lipophilic and hydrophilic antioxidants. Separation of the lipophilic and hydrophilic antioxidant fractions from plasma was accomplished by extracting with hexane after adding water and ethanol to the plasma (hexane/plasma/ethanol/water, 4:1:2:1, v/v). Lipophilic and hydrophilic antioxidants were efficiently partitioned between hexane and aqueous solvents. Conditions for controlling temperature effects and decreasing assay variability using fluorescein as the fluorescent probe were validated in different laboratories. Incubation (37 degrees C for at least 30 min) of the buffer to which AAPH was dissolved was critical in decreasing assay variability. Lipophilic antioxidants represented 33.1 +/- 1.5 and 38.2 +/- 1.9% of the total antioxidant capacity of the protein free plasma in two independent studies of 6 and 10 subjects, respectively. Methods are described for application of the assay techniques to other types of biological and food samples.
Telescience operations with the solar array module plasma interaction experiment
NASA Technical Reports Server (NTRS)
Wald, Lawrence W.; Bibyk, Irene K.
1995-01-01
The Solar Array Module Plasma Interactions Experiment (SAMPIE) is a flight experiment that flew on the Space Shuttle Columbia (STS-62) in March 1994, as part of the OAST-2 mission. The overall objective of SAMPIE was to determine the adverse environmental interactions within the space plasma of low earth orbit (LEO) on modern solar cells and space power system materials which are artificially biased to high positive and negative direct current (DC) voltages. The two environmental interactions of interest included high voltage arcing from the samples to the space plasma and parasitic current losses. High voltage arcing can cause physical damage to power system materials and shorten expected hardware life. parasitic current losses can reduce power system efficiency because electric currents generated in a power system drain into the surrounding plasma via parasitic resistance. The flight electronics included two programmable high voltage DC power supplies to bias the experiment samples, instruments to measure the surrounding plasma environment in the STS cargo bay, and the on-board data acquisition system (DAS). The DAS provided in-flight experiment control, data storage, and communications through the Goddard Space Flight Center (GSFC) Hitchhiker flight avionics to the GSFC Payload Operations Control Center (POCC). The DAS and the SAMPIE POCC computer systems were designed for telescience operations; this paper will focus on the experiences of the SAMPIE team regarding telescience development and operations from the GSFC POCC during STS-62. The SAMPIE conceptual development, hardware design, and system verification testing were accomplished at the NASA Lewis Research Center (LeRC). SAMPIE was developed under the In-Space Technology Experiment Program (IN-STEP), which sponsors NASA, industry, and university flight experiments designed to enable and enhance space flight technology. The IN-STEP Program is sponsored by the Office of Space Access and Technology (OSAT).
Sun, L W; Zhang, H Y; Wu, L; Shu, S; Xia, C; Xu, C; Zheng, J S
2014-03-01
The purpose of this study was to assess the metabolic profile of plasma samples from cows with clinical and subclinical ketosis. According to clinical signs and 3-hydroxybutyrate plasma levels, 81 multiparous Holstein cows were selected from a dairy farm 7 to 21 d after calving. The cows were divided into 3 groups: cows with clinical ketosis, cows with subclinical ketosis, and healthy control cows. (1)H-Nuclear magnetic resonance-based metabolomics was used to assess the plasma metabolic profiles of the 3 groups. The data were analyzed by principal component analysis, partial least squares discriminant analysis, and orthogonal partial least-squares discriminant analysis. The differences in metabolites among the 3 groups were assessed. The orthogonal partial least-squares discriminant analysis model differentiated the 3 groups of plasma samples. The model predicted clinical ketosis with a sensitivity of 100% and a specificity of 100%. In the case of subclinical ketosis, the model had a sensitivity of 97.0% and specificity of 95.7%. Twenty-five metabolites, including acetoacetate, acetone, lactate, glucose, choline, glutamic acid, and glutamine, were different among the 3 groups. Among the 25 metabolites, 4 were upregulated, 7 were downregulated, and 14 were both upregulated and downregulated. The results indicated that plasma (1)H-nuclear magnetic resonance-based metabolomics, coupled with pattern recognition analytical methods, not only has the sensitivity and specificity to distinguish cows with clinical and subclinical ketosis from healthy controls, but also has the potential to be developed into a clinically useful diagnostic tool that could contribute to a further understanding of the disease mechanisms. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Cohen, Kevin; Liu, Ying; Luo, Jingqin; Appleton, Catherine M; Colditz, Graham A
2017-04-01
To examine the association of plasma carotenoids, micronutrients in fruits, and vegetables, with risk of premalignant breast disease (PBD) in younger women. Blood samples were collected at the Siteman Cancer Center between 2008 and 2012 from 3537 women aged 50 or younger with no history of cancer or PBD. The analysis included 147 participants diagnosed with benign breast disease or breast carcinoma in situ during a 27-month follow-up and 293 controls. Cases and controls were matched on age, race/ethnicity, and date of and fasting status at blood draw. Plasma carotenoids were quantified. We used logistic regression to calculate odds ratios (ORs) and 95% confidence intervals (CIs) and linear regression to assess racial differences in plasma carotenoids. The risk reduction between the highest and lowest tertiles varied by carotenoid, with β-cryptoxanthin having the greatest reduction (OR 0.62; 95% CI, 0.62-1.09; P trend = 0.056) and total carotenoids the least (OR 0.83; 95% CI, 0.48-1.44; P trend = 0.12). We observed an inverse association between plasma carotenoids and risk of PBD in obese women (BMI ≥ 30 kg/m 2 ; 61 cases and 115 controls) but not lean women (BMI < 25 kg/m 2 ; 54 cases and 79 controls), although the interaction was not statistically significant. Compared to white women, black women had lower levels of α and β-carotene and higher levels of β-cryptoxanthin and lutein/zeaxanthin. We observed suggestive inverse associations between plasma carotenoids and risk of PBD in younger women, consistent with inverse associations reported for invasive breast cancer. Carotenoids may play a role early in breast cancer development.
Cohen, Kevin; Liu, Ying; Luo, Jingqin; Appleton, Catherine M.; Colditz, Graham A.
2017-01-01
Purpose To examine the association of plasma carotenoids, micronutrients in fruits and vegetables, with risk of premalignant breast disease (PBD) in younger women. Methods Blood samples were collected at the Siteman Cancer Center between 2008 and 2012 from 3,537 women aged 50 or younger with no history of cancer or PBD. The analysis included 147 participants diagnosed with benign breast disease or breast carcinoma in situ during a 27-month followup and 293 controls. Cases and controls were matched on age, race/ethnicity, and date of and fasting status at blood draw. Plasma carotenoids were quantified. We used logistic regression to calculate odds ratios (ORs) and 95% confidence intervals (CIs) and linear regression to assess racial differences in plasma carotenoids. Results The risk reduction between the highest and lowest tertiles varied by carotenoid, with β-cryptoxanthin having the greatest reduction (OR 0.62; 95% CI, 0.62–1.09; Ptrend=0.056) and total carotenoids the least (OR 0.83; 95% CI, 0.48–1.44; Ptrend=0.12). We observed an inverse association between plasma carotenoids and risk of PBD in obese women (BMI≥30 kg/m2; 61 cases and 115 controls) but not lean women (BMI<25 kg/m2; 54 cases and 79 controls), although the interaction was not statistically significant. Compared to white women, black women had lower levels of α and β-carotene and higher levels of β-cryptoxanthin and lutein/zeaxanthin. Conclusions We observed suggestive inverse associations between plasma carotenoids and risk of PBD in younger women , consistent with inverse associations reported for invasive breast cancer. Carotenoids may play a role early in breast cancer development. PMID:28190250
Rinchard, J; Dabrowski, K; Garcia-Abiado, M A; Ottobre, J
1999-08-01
Oral administration of 17alpha-methyltestosterone (MT) was used to induce masculinization of sexually undifferentiated muskellunge, Esox masquinongy. Three groups of muskellunge (mean weight, 2.5 +/- 0.6 g) were submitted to MT treatment (15 mg of MT/kg) for 60 days. An additional one group was used as a control (hormone-free diet). Food was distributed over a 10-h period by using automatic belt feeders. Blood was sampled in both control and treated fish at different intervals during and after feeding: before (0 h), at 3 h, 6 h, and cessation of feeding (10 h), and after a fast of 22 h (32 h). MT had no significant effect on growth and survival in muskellunge 6 months after the treatment. Concentrations of plasma MT increased during the feeding period and reached their maximum levels 6 or 10 h after starting feeding. This rapid increase of MT indicated a rapid absorption of this steroid. Plasma MT levels then declined and reached a radir by 22 h after cessation of feeding, suggesting that MT is rapidly metabolized and excreted. The profiles of plasma testosterone during the MT treatment did not differ significantly between control and MT-treated groups. During and after the MT treatment, the concentration of plasma testosterone did not differ significantly between control and MT-treated groups. Moreover, no sexual dimorphism of testosterone levels was observed. Six months after treatment, the sex ratio in MT-treated groups (33% males, 62% females, and 5% intersex) was opposite to control (70% and 30%, respectively) and differed significantly. This suggests that at 15 mg of MT/kg over 60 days, a paradoxical feminization took place.
Antibody to fibroblast growth factor 23-peptide reduces excreta phosphorus of laying hens.
Ren, Zhouzheng; Ebrahimi, Marziyeh; Bütz, Daniel E; Sand, Jordan M; Zhang, Keying; Cook, Mark E
2017-01-01
Novel strategies to minimize the excretion of phosphorus in swine and poultry are critical in minimizing environmental degradation. We have developed a synthetic peptide vaccine to produce autoantibodies to fibroblast growth factor 23 (FGF-23), a bone-derived hormone that blocks kidney phosphate resorption and indirectly reduces intestinal phosphate absorption. Single Comb White Leghorn laying hens, fed a standard diet (inorganic phosphorus, Pi = 0.4%), were immunized over the course of 4 weeks with either a FGF-23 peptide vaccine or adjuvant control (without FGF-23 peptide). At peak antibody titer to the peptide (week 5), 24-h excreta were collected and hens were blood sampled (represents 0.4% Pi treatment). Hens were then fed a 0.8% Pi diet and blood was sampled at 24 and 72 h and 24-h excreta were collected at 12 to 36 and 60 to 84 h (represents 0.8% Pi treatment). Increasing Pi from 0.4 to 0.8% increased (P < 0.05) percent excreta phosphorus, total 24-h phosphorus excretion, and plasma levels of FGF-23 and phosphate in either control or FGF-23 peptide vaccinated hens as early as the first sampling period. FGF-23 peptide vaccinated hens fed 0.4% Pi had reduced (P < 0.05) percent excreta phosphorus, total 24 h phosphorus excretion, and plasma levels of FGF-23 and iPTH, and increased (P < 0.05) plasma levels of phosphate and 1,25(OH) 2 D 3 when compared to control vaccinated hens fed 0.4% Pi. In the first collection period post 0.8% Pi feeding, FGF-23 peptide vaccinated hens had reduced (P < 0.05) plasma levels of FGF-23 and iPTH, and increased (P < 0.05) plasma levels of phosphate and 1,25(OH) 2 D 3 , and tended to have reduced percent excreta phosphorus (P = 0.085) and total 24 h phosphorus excretion (P = 0.078) when compared to control vaccinated hens. Results during the second collection period post 0.8% Pi feeding were similar to that at the first collection period. These results are the first to show that the inhibition of FGF-23 action by a peptide vaccine (via neutralizing antibody) reduced phosphorus excretion. The approach presented provides new information on phosphorus metabolism in the laying hen. © 2016 Poultry Science Association Inc.
Limonier, Franck; Van Steendam, Katleen; Waeterloos, Geneviève; Brusselmans, Koen; Sneyers, Myriam; Deforce, Dieter
2017-01-30
Thromboembolic events (TEE) associated to trace amounts of plasmatic activated coagulation factor XI (FXIa) in administrated immunoglobulin (Ig) have recently raised concerns and hence there is a need for highly sensitive profiling of residual plasma source proteins. This study aims to consider LC-ESI-QTOF data-dependent acquisition in combination with sample fractionation for this purpose. Sample fractionation proved mandatory to enable identification of plasma residuals. Two approaches were compared: Ig depletion with protein G - protein A affinity chromatography and low-abundant protein enrichment with a combinatorial peptide ligand library (ProteoMiner™, Bio-Rad). The latter allowed a higher number of identifications. Highly sensitive detection of prothrombotic FXIa was assessed with confident identification of a 1ng/mg spike. Moreover, different residuals compositions were profiled for various commercial Ig products. Using a quantitative label free analysis, a TEE-positive Ig batch was distinguished from other regular Ig products, with increased levels of FXIa but also other unique proteins. This could have prevented the recently observed TEE problems with Ig. The method is a convenient tool to better characterize Ig products after any plasma pool or manufacture process change, gaining insights in the product quality profile without any prior information required. This study characterized residual plasma proteins in Ig products, using bottom-up LC-MS/MS with conventional data-dependent acquisition, preceded by sample fractionation. Without any prior information or target-specific development, >30 proteins were identified in a commercial Ig product. Quality control relevance was demonstrated with the identification of FXIa spiked at 1ng/mg in Ig, which is below the minimal thrombotic dose of 3ng/mg observed in an in vivo model. Relative label-free quantitation highlighted significant differences in normalized abundances of residual proteins between Ig products. A TEE-positive batch was distinguished by unique profile of residual proteins, including FXIa but also various blood stream-regulator proteins (fibrinogen, angiotensinogen, antithrombin-III, complement component C8, …). Those results emphasize that MS screening is a relevant first-line test to prevent any undesired concentration of plasma impurities after a plasma pool or manufacturing process change. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Schirmack, Janosch; Fiebrandt, Marcel; Stapelmann, Katharina; Schulze-Makuch, Dirk
2016-05-26
We used Ar plasma-sterilization at a temperature below 80 °C to examine its effects on the viability of microorganisms when intermixed with tested soil. Due to a relatively low temperature, this method is not thought to affect the properties of a soil, particularly its organic component, to a significant degree. The method has previously been shown to work well on spacecraft parts. The selected microorganism for this test was Deinococcus radiodurans R1, which is known for its remarkable resistance to radiation effects. Our results showed a reduction in microbial counts after applying a low temperature plasma, but not to a degree suitable for a sterilization of the soil. Even an increase of the treatment duration from 1.5 to 45 min did not achieve satisfying results, but only resulted in in a mean cell reduction rate of 75% compared to the untreated control samples.
Hisamatsu, Tadakazu; Okamoto, Susumu; Hashimoto, Masaki; Muramatsu, Takahiko; Andou, Ayatoshi; Uo, Michihide; Kitazume, Mina T.; Matsuoka, Katsuyoshi; Yajima, Tomoharu; Inoue, Nagamu; Kanai, Takanori; Ogata, Haruhiko; Iwao, Yasushi; Yamakado, Minoru; Sakai, Ryosei; Ono, Nobukazu; Ando, Toshihiko; Suzuki, Manabu; Hibi, Toshifumi
2012-01-01
Background Inflammatory bowel disease (IBD) is a chronic intestinal disorder that is associated with a limited number of clinical biomarkers. In order to facilitate the diagnosis of IBD and assess its disease activity, we investigated the potential of novel multivariate indexes using statistical modeling of plasma amino acid concentrations (aminogram). Methodology and Principal Findings We measured fasting plasma aminograms in 387 IBD patients (Crohn's disease (CD), n = 165; ulcerative colitis (UC), n = 222) and 210 healthy controls. Based on Fisher linear classifiers, multivariate indexes were developed from the aminogram in discovery samples (CD, n = 102; UC, n = 102; age and sex-matched healthy controls, n = 102) and internally validated. The indexes were used to discriminate between CD or UC patients and healthy controls, as well as between patients with active disease and those in remission. We assessed index performances using the area under the curve of the receiver operating characteristic (ROC AUC). We observed significant alterations to the plasma aminogram, including histidine and tryptophan. The multivariate indexes established from plasma aminograms were able to distinguish CD or UC patients from healthy controls with ROC AUCs of 0.940 (95% confidence interval (CI): 0.898–0.983) and 0.894 (95%CI: 0.853–0.935), respectively in validation samples (CD, n = 63; UC, n = 120; healthy controls, n = 108). In addition, other indexes appeared to be a measure of disease activity. These indexes distinguished active CD or UC patients from each remission patients with ROC AUCs of 0.894 (95%CI: 0.853–0.935) and 0.849 (95%CI: 0.770–0.928), and correlated with clinical disease activity indexes for CD (rs = 0.592, 95%CI: 0.385–0.742, p<0.001) or UC (rs = 0.598, 95%CI: 0.452–0.713, p<0.001), respectively. Conclusions and Significance In this study, we demonstrated that established multivariate indexes composed of plasma amino acid profiles can serve as novel, non-invasive, objective biomarkers for the diagnosis and monitoring of IBD, providing us with new insights into the pathophysiology of the disease. PMID:22303484
NASA Astrophysics Data System (ADS)
Bayliss, D. L.; Walsh, J. L.; Shama, G.; Iza, F.; Kong, M. G.
2009-11-01
Surface-borne amyloid aggregates with mature fibrils are used as a non-infectious prion model to evaluate cold atmospheric plasmas (CAPs) as a prion inactivation strategy. Using a helium-oxygen CAP jet with pulsed radio-frequency (RF) excitation, amyloid aggregates deposited on freshly cleaved mica discs are reduced substantially leaving only a few spherical fragments of sub-micrometer sizes in areas directly treated by the CAP jet. Outside the light-emitting part of the CAP jet, plasma treatment results in a 'skeleton' of much reduced amyloid stacks with clear evidence of fibril fragmentation. Analysis of possible plasma species and the physical configuration of the jet-sample interaction suggests that the skeleton structures observed are unlikely to have arisen as a result of physical forces of detachment, but instead by progressive diffusion of oxidizing plasma species into porous amyloid aggregates. Composition of chemical bonds of this reduced amyloid sample is very different from that of intact amyloid aggregates. These suggest the possibility of on-site degradation by CAP treatment with little possibility of spreading contamination elsewhere , thus offering a new reaction chemistry route to protein infectivity control with desirable implications for the practical implementation of CAP-based sterilization systems.
Raltegravir cerebrospinal fluid concentrations in HIV-1 infection.
Yilmaz, Aylin; Gisslén, Magnus; Spudich, Serena; Lee, Evelyn; Jayewardene, Anura; Aweeka, Francesca; Price, Richard W
2009-09-01
Raltegravir is an HIV-1 integrase inhibitor currently used in treatment-experienced HIV-1-infected patients resistant to other drug classes. In order to assess its central nervous system penetration, we measured raltegravir concentrations in cerebrospinal fluid (CSF) and plasma in subjects receiving antiretroviral treatment regimens containing this drug. Raltegravir concentrations were determined by liquid chromatography tandem mass spectrometry in 25 paired CSF and plasma samples from 16 HIV-1-infected individuals. The lower limit of quantitation was 2.0 ng/ml for CSF and 10 ng/ml for plasma. Twenty-four of the 25 CSF samples had detectable raltegravir concentrations with a median raltegravir concentration of 18.4 ng/ml (range, <2.0-126.0). The median plasma raltegravir concentration was 448 ng/ml (range, 37-5180). CSF raltegravir concentrations correlated with CSF:plasma albumin ratios and CSF albumin concentrations. Approximately 50% of the CSF specimens exceeded the IC(95) levels reported to inhibit HIV-1 strains without resistance to integrase inhibitors. In addition to contributing to control of systemic HIV-1 infection, raltegravir achieves local inhibitory concentrations in CSF in most, but not all, patients. Blood-brain and blood-CSF barriers likely restrict drug entry, while enhanced permeability of these barriers enhances drug entry.
Plasma-Generating Glucose Monitor Accuracy Demonstrated in an Animal Model
Magarian, Peggy; Sterling, Bernhard
2009-01-01
Introduction Four randomized controlled trials have compared mortality and morbidity of tight glycemic control versus conventional glucose for intensive care unit (ICU) patients. Two trials showed a positive outcome. However, one single-center trial and a large multicenter trial had negative results. The positive trials used accurate portable lab analyzers. The negative trial allowed the use of meters. The portable analyzer measures in filtered plasma, minimizing the interference effects. OptiScan Biomedical Corporation is developing a continuous glucose monitor using centrifuged plasma and mid-infrared spectroscopy for use in ICU medicine. The OptiScanner draws approximately 0.1 ml of blood every 15 min and creates a centrifuged plasma sample. Internal quality control minimizes sample preparation error. Interference adjustment using this technique has been presented at the Society of Critical Care Medicine in separate studies since 2006. Method A good laboratory practice study was conducted on three Yorkshire pigs using a central venous catheter over 6 h while performing a glucose challenge. Matching Yellow Springs Instrument glucose readings were obtained. Results Some 95.7% of the predicted values were in the Clarke Error Grid A zone and 4.3% in the B zone. Of those in the B zone, all were within 3.3% of the A zone boundaries. The coefficient of determination (R2) was 0.993. The coefficient of variance was 5.02%. Animal necropsy and blood panels demonstrated safety. Conclusion The OptiScanner investigational device performed safely and accurately in an animal model. Human studies using the device will begin soon. PMID:20144396
Niobium thin film coating on a 500-MHz copper cavity by plasma deposition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haipeng Wang; Genfa Wu; H. Phillips
2005-05-16
A system using an Electron Cyclotron Resonance (ECR) plasma source for the deposition of a thin niobium film inside a copper cavity for superconducting accelerator applications has been designed and is being constructed. The system uses a 500-MHz copper cavity as both substrate and vacuum chamber. The ECR plasma will be created to produce direct niobium ion deposition. The central cylindrical grid is DC biased to control the deposition energy. This paper describes the design of several subcomponents including the vacuum chamber, RF supply, biasing grid and magnet coils. Operational parameters are compared between an operating sample deposition system andmore » this system. Engineering work progress toward the first plasma creation will be reported here.« less
A comparison of serum and plasma cytokine values using a multiplexed assay in cats.
Gruen, Margaret E; Messenger, Kristen M; Thomson, Andrea E; Griffith, Emily H; Paradise, Hayley; Vaden, Shelly; Lascelles, B D X
2016-12-01
Degenerative joint disease (DJD) is highly prevalent in cats, and pain contributes to morbidity. In humans, alterations of cytokine concentrations have been associated with joint deterioration and pain. Similar changes have not been investigated in cats. Cytokine concentrations can be measured using multiplex technology with small samples of serum or plasma, however, serum and plasma are not interchangeable for most bioassays. Correlations for cytokine concentrations between serum and plasma have not been evaluated in cats. To evaluate the levels of detection and agreement between serum and plasma samples in cats. Paired serum and plasma samples obtained from 38 cats. Blood was collected into anti-coagulant free and EDTA Vacutainer ® tubes, serum or plasma extracted, and samples frozen at -80°C until testing. Duplicate samples were tested using a 19-plex feline cytokine/chemokine magnetic bead panel. Agreement between serum and plasma for many analytes was high, however correlation coefficients ranged from -0.01 to 0.97. Results from >50% of samples were below the lower limit of quantification for both serum and plasma for nine analytes, and for an additional three analytes for plasma only. While serum and plasma agreement was generally good, detection was improved using serum samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Increased adrenal steroid secretion in response to CRF in women with hypothalamic amenorrhea.
Genazzani, A D; Bersi, C; Luisi, S; Fruzzetti, F; Malavasi, B; Luisi, M; Petraglia, F; Genazzani, A R
2001-09-01
To evaluate adrenal steroid hormone secretion in response to corticotropin-releasing factor (CRF) or to adrenocorticotropin hormone in women with hypothalamic amenorrhea. Controlled clinical study. Department of Reproductive Medicine and Child Development, Section of Gynecology and Obstetrics, University of Pisa, Italy. Fifteen women with hypothalamic amenorrhea were enrolled in the study. Eight normal cycling women were used as control group. Blood samples were collected before and after an injection of ovine CRF (0.1 microg/kg iv bolus) or after synthetic ACTH (0.25 mg iv). Plasma levels of ACTH, 17-hydroxypregnenolone (17OHPe), progesterone (P), dehydroepiandrosterone (DHEA), 17-hydroxyprogesterone (17OHP), cortisol (F), 11-deoxycortisol (S) and androstenedione (A). Basal plasma concentrations of ACTH, cortisol, 11-deoxycortisol, DHEA and 17OHPe were significantly higher in patients than in controls, whereas plasma levels of progesterone and 17-OHP were significantly lower in patients than in controls. In amenorrheic women the ratio of 17-OHPe/DHEA, of 17-OHPe/17-OHP and of 11-deoxycortisol/cortisol were significantly higher than in controls, while a significant reduction in the ratio of 17-OHP/androstenedione, of 17-OHP/11-deoxycortisol was obtained. In response to corticotropin-releasing factor test, plasma levels of ACTH, cortisol, 17-OHP, 11-deoxycortisol, DHEA and androstenedione were significantly lower in patients than in controls. In response to adrenocorticotropin hormone, plasma levels of 17-OHP, androstenedione and androstenedione/cortisol were significantly higher in patients than in controls. Patients suffering for hypothalamic amenorrhea showed an increased activation of hypothalamus-pituitary-adrenal (HPA) axis, as shown by the higher basal levels and by augmented adrenal hormone response to corticotropin-releasing factor administration. These data suggest a possible derangement of adrenal androgen enzymatic pathway.
Analyses of plasma for metabolic and hormonal changes in rats flown aboard Cosmos 2044
NASA Technical Reports Server (NTRS)
Merrill, Alfred H., Jr.; Wang, Elaine; Mullins, Richard E.; Grindeland, Richard E.; Popova, Irina A.
1992-01-01
Plasmas samples from rats flown aboard Cosmos 2044 were analyzed for the levels of key metabolites, electrolytes, enzymes, and hormones. The major differences between the flight group and the synchronous control were elevations in glucose, cholesterol, phosphate, creatinine, blood urea nitrogen, lactate dehydrogenase, and aspartate aminotransferase and decreased levels of thyroxine. Most of these differences were not mimicked by tail suspension of ground-based rats; however, both flight and suspended rats exhibited inhibited testosterone secretion. Corticosterone, immunoreactive growth hormone, and prolactin showed inconsistent differences from the various control groups, suggesting that the levels of these hormones were not due to actual or simulated microgravity.
Rani, Susheela; Malik, Ashok K; Singh, Baldev
2012-02-01
A method for the simultaneous determination of the antiepileptic drugs, phenobarbital (PHB), phenytoin (PTN), carbamazepine (CBZ), primidone (PRM) and oxcarbazepine (OXC) in human plasma and urine samples by using micro-extraction in a packed syringe as the sample preparation method connected with LC/UV (MEPS/LC/UV) is described. Micro-extraction in a packed syringe (MEPS) is a new miniaturized, solid-phase extraction technique that can be connected online to gas or liquid chromatography without any modifications. In MEPS approximately 1 mg of the solid packing material is inserted into a syringe (100-250 μL) as a plug. Sample preparation takes place on the packed bed. The bed can be coated to provide selective and suitable sampling conditions. The new method is very promising, easy to use, fully automated, inexpensive and quick. The standard curves were obtained within the concentration range 1-500 ng/mL in both plasma and urine samples. The results showed high correlation coefficients (R(2) >0.988) for all of the analytes within the calibration range. The extraction recovery was found to be between 88.56 and 99.38%. The limit of quantification was found to be between 0.132 and 1.956 ng/mL. The precision (RSD) values of quality control samples (QC) had a maximum deviation of 4.9%. A comparison of the detection limits with similar methods indicates high sensitivity of the present method. The method is applied for the analysis of these drugs in real urine and plasma samples of epileptic patients. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Utilizing Interfaces for Nano- and Micro-scale Control of Thermal Conductivity
2015-08-17
performance of these promising materials by 50%. Ballmilling and spark plasma sintering (SPS) processes were investigated to try to lower the thermal...samples fabricated through the spark plasma sintering ”, Mater Renew Sustain Energy, 3, 31-1 31-6 (2014). DOI: 10.1007/s40243-014-0031-8 9. O. Sologub...for doping of foreign elements (therefore no migration problems) is very striking. In further development, addition of Al as a sintering element was
2013-01-01
Background We have recently reported on the changes in plasma free amino acid (PFAA) profiles in lung cancer patients and the efficacy of a PFAA-based, multivariate discrimination index for the early detection of lung cancer. In this study, we aimed to verify the usefulness and robustness of PFAA profiling for detecting lung cancer using new test samples. Methods Plasma samples were collected from 171 lung cancer patients and 3849 controls without apparent cancer. PFAA levels were measured by high-performance liquid chromatography (HPLC)–electrospray ionization (ESI)–mass spectrometry (MS). Results High reproducibility was observed for both the change in the PFAA profiles in the lung cancer patients and the discriminating performance for lung cancer patients compared to previously reported results. Furthermore, multivariate discriminating functions obtained in previous studies clearly distinguished the lung cancer patients from the controls based on the area under the receiver-operator characteristics curve (AUC of ROC = 0.731 ~ 0.806), strongly suggesting the robustness of the methodology for clinical use. Moreover, the results suggested that the combinatorial use of this classifier and tumor markers improves the clinical performance of tumor markers. Conclusions These findings suggest that PFAA profiling, which involves a relatively simple plasma assay and imposes a low physical burden on subjects, has great potential for improving early detection of lung cancer. PMID:23409863
Mauls, Alec G.; Mesa, Matthew G.
1994-01-01
We tested the efficacy of using electrofishing to collect juvenile fall chinook salmon Oncorhynchus tshawytscha to assess their plasma cortisol concentrations. In laboratory experiments, plasma cortisol titers of fish sampled immediately (<4 s) after a 1.5-s, 500-V DC electroshock were not different from controls (mean ± SE, 28.8 ± 5.2 ng/mL), but within 15 min they were significantly higher (148.2 ± 19.0 ng/mL) than controls. Plasma cortisol levels of fish released through turbines and of those released through the juvenile-bypass system at Bonneville Dam, Oregon-Washington, and collected by electrofishing did not differ from each other or from prerelease samples (about 70 ± 7 ng/mL). Our results indicate that electrofishing can be used to collect fish for stress assessment in the wild, provided fish are sacrificed immediately after capture. We are concerned, however, that the small number of fish we captured by electrofishing may not be representative of the majority of fish that pass through turbines or bypass systems. The fish used in this study were not migrating smolts and so were not typical of juvenile chinook salmon passing through hydroelectric dams on the Columbia River. Developmental as well as species- and stock-related factors should be addressed in future studies.
Gray, Bobby P; Teale, Phil; Pearce, Clive M
2011-04-01
Analysis of equine plasma samples to detect the abuse of anabolic steroids can be complicated when the parent steroid is endogenous to the animal. Anabolic steroids are usually administered intramuscularly as synthetic esters and therefore detection of the exogenous esters provides unequivocal proof of illegal administration. An ultra high performance liquid chromatography tandem mass spectrometric (UPLC-MSMS) method for the analysis of esters of testosterone (propionate, phenylpropionate, isocaproate, and decanoate) and boldenone (undecylenate) in equine plasma has been developed. Esters were extracted from equine plasma using a mixture of hexane and ethyl acetate and treated with methoxyamine hydrochloride to form methyloxime derivatives. Metenolone enanthate was used as an internal standard. After chromatographic separation, the derivatized steroid esters were quantified using selected reaction monitoring (SRM). The limit of detection for all of the steroid esters, based on a signal to noise ratio (S/N) of 3:1, was 1-3 pg/mL. The lower limit of quantification (LLOQ) for the all of the steroid esters was 5 pg/mL when 2 mL of plasma was extracted. Recovery of the steroid esters was 85-97% for all esters except for testosterone decanoate which was recovered at 62%. The intra-day coefficient of variation (CV) for the analysis of plasma quality control (QC) samples was less than 9.2% at 40 pg/mL and less than 6.0% at 400 pg/mL. The developed assay was used to successfully confirm the presence of intact testosterone esters in equine plasma samples following intramuscular injection of Durateston® (mixed testosterone esters). Copyright © 2011 John Wiley & Sons, Ltd.
Bertram, Jens; Brand, Peter; Hartmann, Laura; Schettgen, Thomas; Kossack, Veronika; Lenz, Klaus; Purrio, Ellwyn; Reisgen, Uwe; Kraus, Thomas
2015-10-01
Several existing field studies evaluate aluminium welding works but no thoroughly controlled exposure scenario for welding fume has been described yet. This study provides information about the uptake and elimination of aluminium from welding fumes under controlled conditions. In the Aachen Workplace Simulation Laboratory, we are able to generate welding fumes of a defined particle mass concentration. We exposed 12, until then occupationally unexposed participants with aluminium-containing welding fumes of a metal inert gas (MIG) welding process of a total dust mass concentration of 2.5 mg/m(3) for 6 h. Room air filter samples were collected, and the aluminium concentration in air derived. Urine and plasma samples were collected directly before and after the 6-h lasting exposure, as well as after 1 and 7 days. Human biomonitoring methods were used to determine the aluminium content of the samples with high-resolution continuum source atomic absorption spectrometry. Urinary aluminium concentrations showed significant changes after exposure compared to preexposure levels (mean t(1) (0 h) 13.5 µg/L; mean t(2) (6 h) 23.5 µg/L). Plasma results showed the same pattern but pre-post comparison did not reach significance. We were able to detect a significant increase of the internal aluminium burden of a single MIG aluminium welding process in urine, while plasma failed significance. Biphasic elimination kinetic can be observed. The German BAT of 60 µg/g creatinine was not exceeded, and urinary aluminium returned nearly to baseline concentrations after 7 days.
Protein and glycomic plasma markers for early detection of adenoma and colon cancer.
Rho, Jung-Hyun; Ladd, Jon J; Li, Christopher I; Potter, John D; Zhang, Yuzheng; Shelley, David; Shibata, David; Coppola, Domenico; Yamada, Hiroyuki; Toyoda, Hidenori; Tada, Toshifumi; Kumada, Takashi; Brenner, Dean E; Hanash, Samir M; Lampe, Paul D
2018-03-01
To discover and confirm blood-based colon cancer early-detection markers. We created a high-density antibody microarray to detect differences in protein levels in plasma from individuals diagnosed with colon cancer <3 years after blood was drawn (ie, prediagnostic) and cancer-free, matched controls. Potential markers were tested on plasma samples from people diagnosed with adenoma or cancer, compared with controls. Components of an optimal 5-marker panel were tested via immunoblotting using a third sample set, Luminex assay in a large fourth sample set and immunohistochemistry (IHC) on tissue microarrays. In the prediagnostic samples, we found 78 significantly (t-test) increased proteins, 32 of which were confirmed in the diagnostic samples. From these 32, optimal 4-marker panels of BAG family molecular chaperone regulator 4 (BAG4), interleukin-6 receptor subunit beta (IL6ST), von Willebrand factor (VWF) and CD44 or epidermal growth factor receptor (EGFR) were established. Each panel member and the panels also showed increases in the diagnostic adenoma and cancer samples in independent third and fourth sample sets via immunoblot and Luminex, respectively. IHC results showed increased levels of BAG4, IL6ST and CD44 in adenoma and cancer tissues. Inclusion of EGFR and CD44 sialyl Lewis-A and Lewis-X content increased the panel performance. The protein/glycoprotein panel was statistically significantly higher in colon cancer samples, characterised by a range of area under the curves from 0.90 (95% CI 0.82 to 0.98) to 0.86 (95% CI 0.83 to 0.88), for the larger second and fourth sets, respectively. A panel including BAG4, IL6ST, VWF, EGFR and CD44 protein/glycomics performed well for detection of early stages of colon cancer and should be further examined in larger studies. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Infrared Spectroscopy of Blood for Disease Identification
NASA Astrophysics Data System (ADS)
Pichardo, J. L.; Huerta-Franco, R.; Álvarez, R. R.; Bernal, J.; Gutiérrez-Juárez, G.; Palomares-Anda, P.
2003-09-01
Total reflectance attenuated infrared Fourier transform spectroscopy was used to analyze blood samples. Plasma and red blood cells were separated by centrifugation. The spectra were recorded from 200 to 4000 cm-1 under the same conditions for all samples. Samples of healthy donors were compared with those patients with different diseases (polycythemia and high blood pressure). Patients were under medical control at the time of the study. However, the preliminary results reveal that blood samples from healthy subjects had different infrared spectra compared to the non healthy patients.
NASA Astrophysics Data System (ADS)
Liu, X. M.; Wu, S. L.; Chu, Paul K.; Chung, C. Y.; Chu, C. L.; Yeung, K. W. K.; Lu, W. W.; Cheung, K. M. C.; Luk, K. D. K.
2007-01-01
Water plasma immersion ion implantation (PIII) was conducted on orthopedic NiTi shape memory alloy to enhance the surface electrochemical characteristics. The surface composition of the NiTi alloy before and after H 2O-PIII was determined by X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM) was utilized to determine the roughness and morphology of the NiTi samples. Potentiodynamic polarization tests and electrochemical impedance spectroscopy (EIS) were carried out to investigate the surface electrochemical behavior of the control and H 2O-PIII NiTi samples in simulated body fluids (SBF) at 37 °C as well as the mechanism. The H 2O-PIII NiTi sample showed a higher breakdown potential ( Eb) than the control sample. Based on the AFM results, two different physical models with related equivalent electrical circuits were obtained to fit the EIS data and explain the surface electrochemical behavior of NiTi in SBF. The simulation results demonstrate that the higher resistance of the oxide layer produced by H 2O-PIII is primarily responsible for the improvement in the surface corrosion resistance.
Boone, J S; Tyler, J W; Chambers, J E
2001-01-01
We studied chlorpyrifos, an insecticide present in a commercial dip for treating ectoparasites in dogs, to estimate the amount of transferable residues that children could obtain from their treated pets. Although the chlorpyrifos dip is no longer supported by the manufacturer, the methodology described herein can help determine transferable residues from other flea control insecticide formulations. Twelve dogs of different breeds and weights were dipped using the recommended guidelines with a commercial, nonprescription chlorpyrifos flea dip for 4 consecutive treatments at 3-week intervals (nonshampoo protocol) and another 12 dogs were dipped with shampooing between dips (shampoo protocol). The samples collected at 4 hr and 7, 14, and 21 days after treatment in the nonshampoo protocol averaged 971, 157, 70, and 26 microg chlorpyrifos, respectively; in the shampoo protocol the samples averaged 459, 49, 15, and 10 microg, respectively. The highest single sample was about 7,000 microg collected at 4 hr. The pretreatment specific activities in the plasma of the dogs were about 75 nmol/min/mg protein for butyrylcholinesterase (BChE), and 9 nmol/min/mg protein for acetylcholinesterase (AChE). BChE was inhibited 50-75% throughout the study, and AChE was inhibited 11-18% in the nonshampoo protocol; inhibition was not as great in the shampoo protocol. There was no correlation (p
Carter, Jane V.; Roberts, Henry L.; Pan, Jianmin; Rice, Jonathan D.; Burton, James F.; Galbraith, Norman J.; Eichenberger, M. Robert; Jorden, Jeffery; Deveaux, Peter; Farmer, Russell; Williford, Anna; Kanaan, Ziad; Rai, Shesh N.; Galandiuk, Susan
2016-01-01
OBJECTIVE(S) Develop a plasma-based microRNA (miRNA) diagnostic assay specific for colorectal neoplasms, building upon our prior work. BACKGROUND Colorectal neoplasms (colorectal cancer [CRC] and colorectal advanced adenoma [CAA]) frequently develop in individuals at ages when other common cancers also occur. Current screening methods lack sensitivity, specificity, and have poor patient compliance. METHODS Plasma was screened for 380 miRNAs using microfluidic array technology from a “Training” cohort of 60 patients, (10 each) control, CRC, CAA, breast (BC), pancreatic (PC) and lung (LC) cancer. We identified uniquely dysregulated miRNAs specific for colorectal neoplasia (p<0.05, false discovery rate: 5%, adjusted α=0.0038). These miRNAs were evaluated using single assays in a “Test” cohort of 120 patients. A mathematical model was developed to predict blinded sample identity in a 150 patient “Validation” cohort using repeat-sub-sampling validation of the testing dataset with 1000 iterations each to assess model detection accuracy. RESULTS Seven miRNAs (miR-21, miR-29c, miR-122, miR-192, miR-346, miR-372, miR-374a) were selected based upon p-value, area-under-the-curve (AUC), fold-change, and biological plausibility. AUC (±95% CI) for “Test” cohort comparisons were 0.91 (0.85-0.96), 0.79 (0.70-0.88) and 0.98 (0.96-1.0), respectively. Our mathematical model predicted blinded sample identity with 69-77% accuracy between all neoplasia and controls, 67-76% accuracy between colorectal neoplasia and other cancers, and 86-90% accuracy between colorectal cancer and colorectal adenoma. CONCLUSIONS Our plasma miRNA assay and prediction model differentiates colorectal neoplasia from patients with other neoplasms and from controls with higher sensitivity and specificity compared to current clinical standards. PMID:27471839
Alidjinou, Enagnon Kazali; Moukassa, Donatien; Sané, Famara; Twagirimana Nyenyeli, Séraphin; Akoko, Estina Chandrelle; Mountou, Michèle Valy; Bocket, Laurence; Ibara, Jean-Rosaire; Hober, Didier
2014-03-01
The detection of hepatitis B virus (HBV) infection markers by using dried plasma spots from 32 patients living in Congo has been assessed. Considering frozen plasma samples as gold standard, the sensitivity and specificity of HBV serologic markers detection in dried plasma eluted from filter paper were 100%. The sensitivity and the specificity of HBV DNA detection reached 96% and 100%, respectively, with plasma samples dried on filter paper compared to standard samples. Dried plasma samples can represent an alternative to conventional sampling for HBV detection and management of the infection in developing countries. Copyright © 2014 Elsevier Inc. All rights reserved.
The effect of sample storage on the performance and reproducibility of the galactomannan EIA test.
Kimpton, George; White, P Lewis; Barnes, Rosemary A
2014-08-01
Galactomannan enzyme immune assay (GM EIA) is a nonculture test for detecting invasive aspergillosis (IA) forming a key part of diagnosis and management. Recent reports have questioned the reproducibility of indices after sample storage. To investigate this, 198 serum samples (72 from cases and 126 from controls) and 61 plasma samples (24 from cases and 37 from controls), initially tested between 2010 and 2013, were retested to determine any change in index. Data were also collected on circulatory protein levels for false-positive serum samples. Serum indices significantly declined on retesting (median: initial, 0.50, retest, 0.23; P < 0.0001). This was shown to be diagnosis dependent as the decline was apparent on retesting of control samples (median: initial 0.50, retest 0.12; P < 0.0001), but was not evident with case samples (median: initial, 0.80, retest, 0.80; P = 0.724). Plasma samples showed little change on reanalysis after long-term storage at 4°C. Retesting after freezing showed a decrease in index values for controls (median: initial 0.40, retest 0.26; P = 0.0505), but no significant change in cases. Circulatory proteins showed a correlation between serum albumin concentration and difference in index value on retesting. Overall, this study suggests that a lack of reproducibility in GM EIA positivity is only significant when disease is absent. Retesting after freezing helps to differentiate false-positive GM EIA results and, with consecutive positivity, could help to improve accuracy in predicting disease status. The freezing of samples prior to testing could potentially reduce false-positivity rates and the need to retest. © The Author 2014. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Bernick, Charles; Zetterberg, Henrik; Shan, Guogen; Banks, Sarah; Blennow, Kaj
2018-04-02
The objective of this study is to evaluate longitudinal change in plasma neurofilament light (NF-L) and tau levels in relationship to clinical and radiological measures in professional fighters. Participants (active and retired professional fighters and control group) underwent annual blood sampling, 3 Tesla MRI brain imaging, computerized cognitive testing, and assessment of exposure to head trauma. Plasma tau and NF-L concentrations were measured using Simoa assays. Multiple linear regression models were used to compare the difference across groups in regard to baseline measurements, while mixed linear models was used for the longitudinal data with multiple measurements for each participant. Plasma samples were available on 471 participants. Baseline NF-L measures differed across groups (F_3,393=6.99, p=0.0001), with the active boxers having the highest levels. Higher NF-L levels at baseline were correlated with lower baseline MRI regional volumes and lower cognitive scores. The number of sparring rounds completed by the active fighters was correlated with NF-L (95% CI 0.0116-0.4053, p=0.0381), but not tau, levels. Among 126 subjects having multiple yearly samples, there was a significant difference in average yearly percentage change in tau across groups (F_3,83=3.87, p=0.0121).). We conclude that plasma NF-L and tau behave differently in a group of active and retired fighters; NF-L better reflects acute exposure whereas the role of plasma tau levels in signifying chronic change in brain structure over time requires further study.
The protective effect of diosmin on hepatic ischemia reperfusion injury: an experimental study
Tanrikulu, Yusuf; Şahin, Mefaret; Kismet, Kemal; Kilicoglu, Sibel Serin; Devrim, Erdinc; Tanrikulu, Ceren Sen; Erdemli, Esra; Erel, Serap; Bayraktar, Kenan; Akkus, Mehmet Ali
2013-01-01
Liver ischemia reperfusion injury (IRI) is an important pathologic process leading to bodily systemic effects and liver injury. Our study aimed to investigate the protective effects of diosmin, a phlebotrophic drug with antioxidant and anti-inflammatory effects, in a liver IRI model. Forty rats were divided into 4 groups. Sham group, control group (ischemia-reperfusion), intraoperative treatment group, and preoperative treatment group. Ischemia reperfusion model was formed by clamping hepatic pedicle for a 60 minute of ischemia followed by liver reperfusion for another 90 minutes. Superoxide dismutase (SOD) and catalase (CAT) were measured as antioaxidant enzymes in the liver tissues, and malondialdehyde (MDA) as oxidative stress marker, xanthine oxidase (XO) as an oxidant enzyme and glutathione peroxidase (GSH-Px) as antioaxidant enzyme were measured in the liver tissues and the plasma samples. Hepatic function tests were lower in treatment groups than control group (p<0.001 for ALT and AST). Plasma XO and MDA levels were lower in treatment groups than control group, but plasma GSH-Px levels were higher (p<0.05 for all). Tissue MDA levels were lower in treatment groups than control group, but tissue GSH-Px, SOD, CAT and XO levels were higher (p<0.05 for MDA and p<0.001 for others). Samples in control group histopathologically showed morphologic abnormalities specific to ischemia reperfusion. It has been found that both preoperative and intraoperative diosmin treatment decreases cellular damage and protects cells from toxic effects in liver IRI. As a conclusion, diosmin may be used as a protective agent against IRI in elective and emergent liver surgical operations. PMID:24289756
Plasma processing conditions substantially influence circulating microRNA biomarker levels.
Cheng, Heather H; Yi, Hye Son; Kim, Yeonju; Kroh, Evan M; Chien, Jason W; Eaton, Keith D; Goodman, Marc T; Tait, Jonathan F; Tewari, Muneesh; Pritchard, Colin C
2013-01-01
Circulating, cell-free microRNAs (miRNAs) are promising candidate biomarkers, but optimal conditions for processing blood specimens for miRNA measurement remain to be established. Our previous work showed that the majority of plasma miRNAs are likely blood cell-derived. In the course of profiling lung cancer cases versus healthy controls, we observed a broad increase in circulating miRNA levels in cases compared to controls and that higher miRNA expression correlated with higher platelet and particle counts. We therefore hypothesized that the quantity of residual platelets and microparticles remaining after plasma processing might impact miRNA measurements. To systematically investigate this, we subjected matched plasma from healthy individuals to stepwise processing with differential centrifugation and 0.22 µm filtration and performed miRNA profiling. We found a major effect on circulating miRNAs, with the majority (72%) of detectable miRNAs substantially affected by processing alone. Specifically, 10% of miRNAs showed 4-30x variation, 46% showed 30-1,000x variation, and 15% showed >1,000x variation in expression solely from processing. This was predominantly due to platelet contamination, which persisted despite using standard laboratory protocols. Importantly, we show that platelet contamination in archived samples could largely be eliminated by additional centrifugation, even in frozen samples stored for six years. To minimize confounding effects in microRNA biomarker studies, additional steps to limit platelet contamination for circulating miRNA biomarker studies are necessary. We provide specific practical recommendations to help minimize confounding variation attributable to plasma processing and platelet contamination.
Pizarro, Consuelo; Arenzana-Rámila, Irene; Pérez-del-Notario, Nuria; Pérez-Matute, Patricia; González-Sáiz, José María
2016-03-17
Lipid profiling is a promising tool for the discovery and subsequent identification of biomarkers associated with various diseases. However, data quality is quite dependent on the pre-analytical methods employed. To date, potential confounding factors that may affect lipid metabolite levels after the thawing of plasma for biomarker exploration studies have not been thoroughly evaluated. In this study, by means of experimental design methodology, we performed the first in-depth examination of the ways in which thawing conditions affect lipid metabolite levels. After the optimization stage, we concluded that temperature, sample volume and the thawing method were the determining factors that had to be exhaustively controlled in the thawing process to ensure the quality of biomarker discovery. Best thawing conditions were found to be: 4 °C, with 0.25 mL of human plasma and ultrasound (US) thawing. The new US proposed thawing method was quicker than the other methods we studied, allowed more features to be identified and increased the signal of the lipids. In view of its speed, efficiency and detectability, the US thawing method appears to be a simple, economical method for the thawing of plasma samples, which could easily be applied in clinical laboratories before lipid profiling studies. Copyright © 2016 Elsevier B.V. All rights reserved.
Bhandari, Raj K; Manandhar, Erica; Oda, Robert P; Rockwood, Gary A; Logue, Brian A
2014-01-01
An analytical procedure for the simultaneous determination of cyanide and thiocyanate in swine plasma was developed and validated. Cyanide and thiocyanate were simultaneously analyzed by high-performance liquid chromatography tandem mass spectrometry in negative ionization mode after rapid and simple sample preparation. Isotopically labeled internal standards, Na(13)C(15)N and NaS(13)C(15)N, were mixed with swine plasma (spiked and nonspiked), proteins were precipitated with acetone, the samples were centrifuged, and the supernatant was removed and dried. The dried samples were reconstituted in 10 mM ammonium formate. Cyanide was reacted with naphthalene-2,3-dicarboxaldehyde and taurine to form N-substituted 1-cyano[f]benzoisoindole, while thiocyanate was chemically modified with monobromobimane to form an SCN-bimane product. The method produced dynamic ranges of 0.1-50 and 0.2-50 μM for cyanide and thiocyanate, respectively, with limits of detection of 10 nM for cyanide and 50 nM for thiocyanate. For quality control standards, the precision, as measured by percent relative standard deviation, was below 8 %, and the accuracy was within ±10 % of the nominal concentration. Following validation, the analytical procedure successfully detected cyanide and thiocyanate simultaneously from the plasma of cyanide-exposed swine.
Van Dyck, E; Van de Velden, L; Ndoye, I; Piot, P; Meheus, A
1993-01-01
The availability of simple diagnostic methods may contribute to more efficient control of sexually transmitted diseases (STDs) in developing countries. For the detection of syphilis, a simple rapid plasma reagin (RPR) "teardrop" assay for finger-prick blood samples was developed in 1962. The reliability of this test is compared with RPR, Treponema pallidum hemagglutination assay (TPHA), and fluorescent treponemal antibody absorption (FTA-Abs) assays performed on venous blood samples. To evaluate the potential usefulness of the finger-stick RPR teardrop assay for diagnosis of syphilis in settings with poor medical resources. Pregnant women evaluated at two health centers in Pikine, Senegal were tested for STDs. The RPR teardrop assay was performed on plasma from blood samples obtained by finger prick, and standard RPR, TPHA, and FTA-Abs procedures were performed on serum obtained by vein puncture. The sensitivity and specificity of the finger-prick RPR teardrop assay were 69.7% and 96.5%, respectively, and its reactivity was correlated with RPR serum antibody titer. The finger-prick RPR teardrop assay is not a reliable alternative to the classic serum RPR test.
Decreased insulin response in dairy cows following a four-day fast to induce hepatic lipidosis.
Oikawa, S; Oetzel, G R
2006-08-01
Negative energy balance has been implicated in the development of fatty liver, insulin resistance, and impaired health in dairy cows. A 4-d fasting model previously was reported to increase liver triglycerides more than 2.5-fold. The purpose of the present study was to evaluate insulin response in this fasting model. Nonlactating, nonpregnant Holstein cows were fasted for 4 d (6 cows) or fed continuously as control cows (4 cows). Samples were collected 5 d before fasting, during fasting, and immediately after the 4-d fast, 8 d after the fast, and 16 d after the fast. Fasted cows had greater liver triglyceride content (49.4 vs. 16.2 mg/g, wet-weight basis) at the end of the fasting period compared with control cows. Fasted cows also had increased plasma nonesterified fatty acid (NEFA) concentrations (1.24 vs. 0.21 mmol/L) and increased plasma beta-hydroxybutyrate (BHBA) concentrations at the end of the fasting period. Liver triglyceride, plasma NEFA, and plasma BHBA in fasted cows returned to prefasting concentrations by the end of the experiment. Plasma glucose concentrations were not affected by fasting. Plasma insulin concentrations were decreased (6.3 vs. 14.1 microU/mL) and insulin-stimulated blood glucose reduction was decreased (24.9 vs. 48.6%) in the fasted cows compared with control cows at the end of the fast, indicating reduced insulin response. Insulin response was negatively correlated with plasma NEFA and liver triglycerides. Decreased insulin response may be an important complication of negative energy balance and hepatic lipidosis.
Chen, Hui; Shi, Qi; Qing, Ying; Yao, Yi-chen; Cao, Ying-guang
2016-02-01
The aim of this study was to investigate the cytotoxicity of modified nonequilibrium plasma with chlorhexidine digluconate (CHX) on human gingival fibroblasts (HGFs), and to evaluate the biosecurity of modified nonequilibrium plasma with 2% CHX as a new method of root canal treatment. Tissue samples taken from human gingiva were primarily cultured and passaged. Cells from passages 3-7 were used. HGFs were treated by modified nonequilibrium plasma with 2% CHX for 0 min (control group), 30 s, 1 min, 1.5 min, 3 min, 5 min, and 10 min, respectively, and then they were incubated for 0, 24, and 48 h. After that, cell counting kit-8 (CCK-8) assay was applied to analyze the cytotoxicity of modified nonequilibrium plasma with 2% CHX on HGFs. There was no significant difference between the 0 h group treated with the modified nonequilibrium plasma for 1 min and the control group (P>0.05). However, there were significant differences between all the other treated groups and the control group (P<0.05). When treated for 1.5 min or shorter, the cell viability was obviously increased; while treated for 3 min or longer, it was obviously reduced. Moreover, when successively cultured for 0, 24, and 48 h, cell viability was decreased at first and then increased in the 3-min-treated and 5-min-treated groups. The modified nonequilibrium plasma with 2% CHX was of no influence on cell viability in 1.5 min treatment, and it could be safely used on root canal treatment.
Poe, Amanda; Duong, Ngocvien Thi; Bedi, Kanwar; Kodani, Maja
2018-03-01
Diagnosis of hepatitis C virus (HCV) infection is based on testing for antibodies to HCV (anti-HCV), hepatitis C core antigen (HCV cAg) and HCV RNA. To ensure quality control (QC) and quality assurance (QA), proficiency panels are provided by reference laboratories and various international organizations, requiring costly dry ice shipments to maintain specimen integrity. Alternative methods of specimen preservation and transport can save on shipping and handling and help in improving diagnostics by facilitating QA/QC of various laboratories especially in resource limited countries. Plasma samples positive for anti-HCV and HCV RNA were either dried using dried tube specimens (DTS) method or lyophilization for varying durations of time and temperature. Preservation of samples using DTS method resulted in loss of anti-HCV reactivity for low-positive samples and did not generate enough volume for HCV RNA testing. Lyophilized samples tested positive for anti-HCV even after storage at 4 °C and 25 °C for 12 weeks. Further, HCV RNA was detectable in 5 of 5 (100%) samples over the course of 12 week storage at 4, 25, 37 and 45 °C. In conclusion, lyophilization of specimens maintains integrity of plasma samples for testing for markers of HCV infection and can be a potent mode of sharing proficiency samples without incurring huge shipping costs and avoids challenges with dry ice shipments between donor and recipient laboratories. Copyright © 2017. Published by Elsevier B.V.
López-Andrés, Patricia; Luciano, Giuseppe; Vasta, Valentina; Gibson, Trevor M; Biondi, Luisa; Priolo, Alessandro; Mueller-Harvey, Irene
2013-08-01
A total of sixteen lambs were divided into two groups and fed two different diets. Of these, eight lambs were fed a control diet (C) and eight lambs were fed the C diet supplemented with quebracho tannins (C+T). The objective of the present study was to assess whether dietary quebracho tannins can improve the antioxidant capacity of lamb liver and plasma and if such improvement is due to a direct transfer of phenolic compounds or their metabolites, to the animal tissues. Feed, liver and plasma samples were purified by solid-phase extraction (SPE) and analysed by liquid chromatography-MS for phenolic compounds. Profisitinidin compounds were identified in the C+T diet. However, no phenolic compounds were found in lamb tissues. The liver and the plasma from lambs fed the C+T diet displayed a greater antioxidant capacity than tissues from lambs fed the C diet, but only when samples were not purified with SPE. Profisetinidin tannins from quebracho seem not to be degraded or absorbed in the gastrointestinal tract. However, they induced antioxidant effects in animal tissues.
NASA Astrophysics Data System (ADS)
Peng, Shujing; Liu, Xiulan; Sun, Jie; Gao, Zhiqiang; Yao, Lan; Qiu, Yiping
2010-04-01
This paper studies the influence of moisture absorption of cotton fabrics on the effectiveness of atmospheric pressure plasma jet (APPJ) on desizing of polyvinyl alcohol (PVA). Cotton fabrics with three different moisture regains (MR), namely 1.8%, 7.3%, and 28.4% corresponding to 10%, 65%, and 98% of relative humidity respectively, are treated for 16 s, 32 s, 48 s, and 64 s. X-ray photoelectron spectroscopy analysis indicates that the plasma treated PVA has higher oxygen concentration than the control. Mass loss results show that the fabric with the highest MR has the largest mass loss after 64 s plasma exposure. Solubility measurement reveals that the sample with the lowest MR has the highest desizing efficacy and the percent desizing ratio reaches 96% after 64 s exposure plus a 20 min hot wash, which is shown as clean as the unsized sample through scanning electron microscopy analysis. The yarn tensile strength test results show that APPJ has no negative effect on fabric tensile strength.
Naraharisetti, Suresh Babu; Kirby, Brian J.; Hebert, Mary F.; Easterling, Thomas R.; Unadkat, Jashvant D.
2009-01-01
Glyburide (glibenclamide, INN), a second generation sulfonylurea is widely used in the treatment of gestational diabetes mellitus (GDM). None of the previously reported analytical methods provide adequate sensitivity for the expected sub-nanogram/mL maternal and umbilical cord plasma concentrations of glyburide during pregnancy. We developed and validated a sensitive and low sample volume liquid chromatographic-mass spectrometric (LC-MS) method for simultaneous determination of glyburide (GLY) and its metabolite, 4-transhydroxy glyburide (M1) in human plasma (0.5 ml) or urine (0.1 ml). The limits of quantitation (LOQ) for GLY and M1 in plasma were 0.25 and 0.40 ng/mL, respectively whereas it was 1.06 ng/mL for M1 in urine. As measured by quality control samples, precision (% coefficient of variation) of the assay was < 15% whereas the accuracy (% deviation from expected) ranged from −10.1–14.3%. We found that the GLY metabolite, M1 is excreted in the urine as the glucuronide-conjugate. PMID:17980680
Talic, Nabeel F; Alnahwi, Hasan H; Al-Faraj, Ali S
2013-10-01
The aim of this study was to measure the amount of nickel (Ni) and chromium (Cr) released into the saliva of Saudi patients treated with fixed orthodontic appliances. Ninety salivary samples were collected in a cross-sectional manner. Forty samples were collected from patients (17 males, 23 females) with fixed orthodontic appliances after different periods of orthodontic treatment ranging from the first month and up to 32 months into treatment. The fixed orthodontic appliance consisted of 4 bands, 20 stainless steel brackets, and upper and lower nickel titanium or stainless-steel arch wires. The other 50 samples were collected from people without appliances (24 males, 26 females). Samples were analyzed using Inductive Coupled Plasma/Mass Spectrometry and Inductively Coupled Plasma Optical Emission Spectroscopy to measure Ni and Cr levels, respectively. Student's t-test was used to compare Ni and Cr levels in the treated and untreated control groups. The mean Ni level was 4.197 μg/L in the experimental group and 2.3 μg/L in the control group (p < 0.05). The mean Cr level was 2.9 μg/L in the experimental group and 3.3 μg/L in the control group (p < 0.05). Fixed orthodontic appliances resulted in a non-toxic increase in salivary levels of Ni, but no change in Cr levels. Duration of orthodontic treatment did not affect Ni and Cr levels in the saliva.
Sam, Soya S; Kurpewski, Jaclynn R; Cu-Uvin, Susan; Caliendo, Angela M
2016-04-01
Quantification of HIV-1 RNA has become the standard of care in the clinical management of HIV-1-infected individuals. The objective of this study was to evaluate performance characteristics and relative workflow of the Aptima HIV-1 Quant Dx assay in comparison with the Abbott RealTime HIV-1 assay using plasma and cervicovaginal lavage (CVL) specimens. Assay performance was evaluated by using an AcroMetrix HIV-1 panel, AcroMetrix positive controls, Qnostics and SeraCare HIV-1 evaluation panels, 208 clinical plasma samples, and 205 matched CVL specimens on the Panther and m2000 platforms. The Aptima assay demonstrated good linearity over the quantification range tested (2 to 5 log10copies/ml), and there was strong linear correlation between the assays (R(2)= 0.99), with a comparable coefficient of variance of <5.5%. For the plasma samples, Deming regression analyses and Bland-Altman plots showed excellent agreement between the assays, with an interassay concordance of 91.35% (kappa = 0.75; 95% confidence interval [CI], 0.65 to 0.85), and on average, the viral loads determined by the Aptima assay were 0.21 log10copies/ml higher than those determined by the RealTime assay. The assays differed in their sensitivity for quantifying HIV-1 RNA loads in CVL samples, with the Aptima and RealTime assays detecting 30% and 20%, respectively. Aptima had fewer invalid results, and on average, the viral loads in CVL samples quantified by the Aptima assay were 0.072 log10copies/ml higher than those of the RealTime assay. Our results demonstrate that the Aptima assay is sensitive and accurate in quantifying viral loads in both plasma and CVL specimens and that the fully automated Panther system has all the necessary features suitable for clinical laboratories demanding high-throughput sample processing. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Kurpewski, Jaclynn R.; Cu-Uvin, Susan; Caliendo, Angela M.
2016-01-01
Quantification of HIV-1 RNA has become the standard of care in the clinical management of HIV-1-infected individuals. The objective of this study was to evaluate performance characteristics and relative workflow of the Aptima HIV-1 Quant Dx assay in comparison with the Abbott RealTime HIV-1 assay using plasma and cervicovaginal lavage (CVL) specimens. Assay performance was evaluated by using an AcroMetrix HIV-1 panel, AcroMetrix positive controls, Qnostics and SeraCare HIV-1 evaluation panels, 208 clinical plasma samples, and 205 matched CVL specimens on the Panther and m2000 platforms. The Aptima assay demonstrated good linearity over the quantification range tested (2 to 5 log10 copies/ml), and there was strong linear correlation between the assays (R2 = 0.99), with a comparable coefficient of variance of <5.5%. For the plasma samples, Deming regression analyses and Bland-Altman plots showed excellent agreement between the assays, with an interassay concordance of 91.35% (kappa = 0.75; 95% confidence interval [CI], 0.65 to 0.85), and on average, the viral loads determined by the Aptima assay were 0.21 log10 copies/ml higher than those determined by the RealTime assay. The assays differed in their sensitivity for quantifying HIV-1 RNA loads in CVL samples, with the Aptima and RealTime assays detecting 30% and 20%, respectively. Aptima had fewer invalid results, and on average, the viral loads in CVL samples quantified by the Aptima assay were 0.072 log10 copies/ml higher than those of the RealTime assay. Our results demonstrate that the Aptima assay is sensitive and accurate in quantifying viral loads in both plasma and CVL specimens and that the fully automated Panther system has all the necessary features suitable for clinical laboratories demanding high-throughput sample processing. PMID:26842702
Plasma IL-17A levels in patients with late-life depression.
Saraykar, Smita; Cao, Bo; Barroso, Lucelia S; Pereira, Kelly S; Bertola, Laiss; Nicolau, Mariana; Ferreira, Jessica D; Dias, Natalia S; Vieira, Erica L; Teixeira, Antonio L; Silva, Ana Paula M; Diniz, Breno S
2018-01-01
A consistent body of research has confirmed that patients with major depressive disorder (MDD) have increased concentrations of pro-inflammatory cytokines, including IL-6, TNF-α, IL-1β, the soluble IL-2 receptor, and C-reactive protein, compared to controls; however, there is limited information on IL-17A in MDD. Moreover, information about IL-17A in older populations, i.e., patients with late-life depression (LLD), is conspicuously missing from the literature. The purpose of this study was to investigate the role of IL-17A in LLD. A convenience sample of 129 individuals, 74 with LLD and 55 non-depressed controls, were enrolled in this study. The Mann-Whitney U test was used to compare plasma IL-17A levels between LLD and controls subjects, and Spearman's rank order correlation was used to investigate correlation of these levels with clinical, neuropsychological, and cognitive assessments. Plasma IL-17A levels were not statistically different between LLD patients and controls (p = 0.94). Among all subjects (LLD + control), plasma IL-17A did not correlate significantly with depressive symptoms (rho = -0.009, p = 0.92) but a significant correlation was observed with cognitive assessments (rho = 0.22, p = 0.01). Our findings do not support an association between plasma IL-17A levels and LLD. Nevertheless, IL-17A may be associated with cognitive impairment in LLD patients. If this finding is confirmed in future longitudinal studies, modulation of the T-helper 17 cell (Th17) immune response may be a treatment target for cognitive impairment in this population.
Gehanno, P; Darantière, S; Dubreuil, C; Chobaut, J C; Bobin, S; Pages, J C; Renou, G; Bobin, F; Arvis, P; Stass, H
2002-05-01
A pharmacokinetic study was carried out to determine moxifloxacin concentrations in sinus tissue, after oral moxifloxacin 400 mg once daily for 5 days to patients with chronic sinusitis, undergoing elective sinus surgery. Patients were randomly allocated to one of seven treatment groups, in which tissues were sampled 2, 3, 4, 6, 12, 24 or 36 h post-dose. A control group with non-infected nasal polyps was also included. Forty-eight patients (13 female, 35 male, mean age 47.1 years) were allocated to one of each active treatment group (n = 42) or to the control group (n = 6). Tissue and plasma samples were taken simultaneously and stored frozen until assayed by HPLC. Thirty-nine patients were fully valid for pharmacokinetic analysis. The geometric mean moxifloxacin plasma concentration increased from 2.32 mg/L at 2 h to a maximum of 3.37 mg/L at 4 h post-dose, decreasing to 0.37 mg/L at 36 h post-dose. The moxifloxacin concentration in sinus mucosa was consistently greater than that in plasma being 4.56-5.73 mg/kg from 2 to 6 h and 2.81-1.25 mg/kg from 12 to 36 h post-dose. The elimination rates in plasma and sinus tissues were similar. The tissue/plasma ratio was c. 200% between 2 and 6 h, and up to 328.9% at 36 h. Results were similar whatever the site of tissue sampling (maxillary sinus, anterior ethmoid sinus or nasal polyps). Tissue levels exceeded the MIC(90) of all pathogens commonly causing acute sinusitis (e.g. 5-30 x MIC for Streptococcus pneumoniae: 0.25 mg/L). These results sup-port the use of moxifloxacin 400 mg once daily as a regimen for the treatment of sinus infections.
Matton, A.; Engelborghs, S.; Bollengier, F.; Finné, E.; Vanhaeist, L.
1996-01-01
1. The effect of the nootropic drug, piracetam on stress- and subsequent morphine-induced prolactin (PRL) secretion was investigated in vivo in male rats, by use of a stress-free blood sampling and drug administration method by means of a permanent indwelling catheter in the right jugular vein. 2. Four doses of piracetam were tested (20, 100, 200 and 400 mg kg-1), being given intraperitoneally 1 h before blood sampling; control rats received saline instead. After a first blood sample, rats were subjected to immobilization stress and received morphine, 6 mg kg-1, 90 min later. 3. Piracetam had no effect on basal plasma PRL concentration. 4. While in the non-piracetam-treated rats, stress produced a significant rise in plasma PRL concentration, in the piracetam-pretreated rats PRL peaks were attenuated, especially in the group given 100 mg kg-1 piracetam, where plasma PRL concentration was not significantly different from basal values. The dose-response relationship showed a U-shaped curve; the smallest dose had a minor inhibitory effect and the highest dose had no further effect on the PRL rise. 5. In unrestrained rats, morphine led to a significant elevation of plasma PRL concentration. After the application of immobilization stress it lost its ability to raise plasma PRL concentration in the control rats, but not in the piracetam-treated rats. This tolerance was overcome by piracetam in a significant manner but with a reversed dose-response curve; i.e. the smaller the dose of piracetam, the higher the subsequent morphine-induced PRL peak. 6. There is no simple explanation for the mechanism by which piracetam induces these contradictory effects. Interference with the excitatory amino acid system, which is also involved in opiate action, is proposed speculatively as a possible mediator of the effects of piracetam. PMID:8821540
Association between ascites and primary hyperfibrinolysis: A cohort study in 210 dogs.
Zoia, Andrea; Drigo, Michele; Simioni, Paolo; Caldin, Marco; Piek, Christine J
2017-05-01
Coagulation profiles were determined in 70 dogs with ascites, 70 healthy control dogs and 70 sick control dogs without ascites. Dogs with ascites were divided into four sub-groups based on the pathophysiology of fluid formation. Coagulation profile, serum C-reactive protein and frequency of discordant plasma fibrin-fibrinogen degradation products and D-dimer assay results, suggesting primary hyperfibrinolysis, were compared between groups. Within the ascites group, 10 samples of ascitic fluid were transudates due to decreased osmotic pressure, 18 were transudates due to increased hydrostatic pressure, 13 were exudates and 29 were haemorrhagic. Plasma fibrinogen concentrations were significantly lower in dogs with ascites compared to sick dogs without ascites. Activated partial thromboplastin time, prothrombin time, plasma concentrations of fibrin-fibrinogen degradation products and D-dimers, and frequency of primary hyperfibrinolysis, were significantly higher for dogs with ascites compared to both control groups. There was no significant difference in platelet count between groups. The frequency of primary hyperfibrinolysis was highest in dogs with transudative ascites due to increased hydrostatic pressure. Serum C-reactive protein was significantly higher in dogs with ascites compared to both control groups, and significantly and positively correlated with plasma D-dimers. In conclusion, dogs with ascites have an increased frequency of primary hyperfibrinolysis, especially with ascites secondary to increased hydrostatic pressure. The increased inflammation present in these dogs may have activated haemostasis in some cases, explaining the higher plasma D-dimers. Copyright © 2017 Elsevier Ltd. All rights reserved.
Greifenhagen, Uta; Frolov, Andrej; Blüher, Matthias; Hoffmann, Ralf
2016-04-29
Protein glycation refers to the reversible reaction between aldoses (or ketoses) and amino groups yielding relatively stable Amadori (or Heyns) products. Consecutive oxidative cleavage reactions of these products or the reaction of amino groups with other reactive substances (e.g. α-dicarbonyls) yield advanced glycation end products (AGEs) that can alter the structures and functions of proteins. AGEs have been identified in all organisms, and their contents appear to rise with some diseases, such as diabetes and obesity. Here, we report a pilot study using highly sensitive and specific proteomics approach to identify and quantify AGE modification sites in plasma proteins by reversed phase HPLC mass spectrometry in tryptic plasma digests. In total, 19 AGE modification sites corresponding to 11 proteins were identified in patients with type 2 diabetes mellitus under poor glycemic control. The modification degrees of 15 modification sites did not differ among cohorts of normoglycemic lean or obese and type 2 diabetes mellitus patients under good and poor glycemic control. The contents of two amide-AGEs in human serum albumin and apolipoprotein A-II were significantly higher in patients with poor glycemic control, although the plasma levels of both proteins were similar among all plasma samples. These two modification sites might be useful to predict long term, AGE-related complications in diabetic patients, such as impaired vision, increased arterial stiffness, or decreased kidney function. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.
Losartan alleviates hyperuricemia-induced atherosclerosis in a rabbit model.
Zheng, Hongchao; Li, Ning; Ding, Yueyou; Miao, Peizhi
2015-01-01
To investigate the mechanisms underlying the therapeutic effects of losartan on hyperuricemia-induced aortic atherosclerosis, in an experimental rabbit model. Male rabbits (n = 48) were divided into control, hyperuricemia (HU), hypercholesterolemia + hyperuricemia (HC + HU) and high-purine with 30-mg/kg/d losartan (HU + losartan) groups. Serum uric acid (UA) and plasma renin and angiotensin II activities were determined. Aortic tissue specimens were analyzed for histological changes and proliferating cell nuclear antigen (PCNA). Liver tissues were sampled for quantitative analyses of liver low-density lipoprotein receptor (LDLR) mRNA and protein via reverse transcription polymerase chain reaction and western blotting. After 12 weeks, serum UA and plasma renin and plasma angiotensin II activities were enhanced in the HU and HU + HC groups (P < 0.001) compared to the control, whereas in the HU + losartan group plasma renin activity was not different and serum UA concentrations as well as plasma angiotensin II activity were moderately enhanced (P < 0.05). Smooth muscle cell (SMC) PCNA expression increased strongly in the HU and HU + HC groups (P < 0.001), but was less pronounced in the HU + losartan group. In contrast, transcription and expression of LDLR mRNA and protein were significantly higher in the control and HU + losartan groups compared to the HU and HU + HC groups. Both the HU and HU + HC groups had elevated intima thickness and intima areas compared to the control and HU + losartan groups. Losartan can alleviate experimental atherosclerosis induced by hyperuricemia.
Losartan alleviates hyperuricemia-induced atherosclerosis in a rabbit model
Zheng, Hongchao; Li, Ning; Ding, Yueyou; Miao, Peizhi
2015-01-01
Objective: To investigate the mechanisms underlying the therapeutic effects of losartan on hyperuricemia-induced aortic atherosclerosis, in an experimental rabbit model. Methods: Male rabbits (n = 48) were divided into control, hyperuricemia (HU), hypercholesterolemia + hyperuricemia (HC + HU) and high-purine with 30-mg/kg/d losartan (HU + losartan) groups. Serum uric acid (UA) and plasma renin and angiotensin II activities were determined. Aortic tissue specimens were analyzed for histological changes and proliferating cell nuclear antigen (PCNA). Liver tissues were sampled for quantitative analyses of liver low-density lipoprotein receptor (LDLR) mRNA and protein via reverse transcription polymerase chain reaction and western blotting. Results: After 12 weeks, serum UA and plasma renin and plasma angiotensin II activities were enhanced in the HU and HU + HC groups (P < 0.001) compared to the control, whereas in the HU + losartan group plasma renin activity was not different and serum UA concentrations as well as plasma angiotensin II activity were moderately enhanced (P < 0.05). Smooth muscle cell (SMC) PCNA expression increased strongly in the HU and HU + HC groups (P < 0.001), but was less pronounced in the HU + losartan group. In contrast, transcription and expression of LDLR mRNA and protein were significantly higher in the control and HU + losartan groups compared to the HU and HU + HC groups. Both the HU and HU + HC groups had elevated intima thickness and intima areas compared to the control and HU + losartan groups. Conclusions: Losartan can alleviate experimental atherosclerosis induced by hyperuricemia. PMID:26617751
Cracks and nanodroplets produced on tungsten surface samples by dense plasma jets
NASA Astrophysics Data System (ADS)
Ticoş, C. M.; Galaţanu, M.; Galaţanu, A.; Luculescu, C.; Scurtu, A.; Udrea, N.; Ticoş, D.; Dumitru, M.
2018-03-01
Small samples of 12.5 mm in diameter made from pure tungsten were exposed to a dense plasma jet produced by a coaxial plasma gun operated at 2 kJ. The surface of the samples was analyzed using a scanning electron microscope (SEM) before and after applying consecutive plasma shots. Cracks and craters were produced in the surface due to surface tensions during plasma heating. Nanodroplets and micron size droplets could be observed on the samples surface. An energy-dispersive spectroscopy (EDS) analysis revealed that the composition of these droplets coincided with that of the gun electrode material. Four types of samples were prepared by spark plasma sintering from powders with the average particle size ranging from 70 nanometers up to 80 μm. The plasma power load to the sample surface was estimated to be ≈4.7 MJ m-2 s-1/2 per shot. The electron temperature and density in the plasma jet had peak values 17 eV and 1.6 × 1022 m-3, respectively.
Scarpellini, Bruno; Zanoni, Michelle; Sucupira, Maria Cecilia Araripe; Truong, Hong-Ha M; Janini, Luiz Mario Ramos; Segurado, Ismael Dale Cotrin; Diaz, Ricardo Sobhie
2016-01-01
We evaluated plasma samples HIV-infected individuals with different phenotypic profile among five HIV-infected elite controllers and five rapid progressors after recent HIV infection and one year later and from 10 individuals subjected to antiretroviral therapy, five of whom were immunological non-responders (INR), before and after one year of antiretroviral treatment compared to 175 samples from HIV-negative patients. A targeted quantitative tandem mass spectrometry metabolomics approach was used in order to determine plasma metabolomics biosignature that may relate to HIV infection, pace of HIV disease progression, and immunological response to treatment. Twenty-five unique metabolites were identified, including five metabolites that could distinguish rapid progressors and INRs at baseline. Severe deregulation in acylcarnitine and sphingomyelin metabolism compatible with mitochondrial deficiencies was observed. β-oxidation and sphingosine-1-phosphate-phosphatase-1 activity were down-regulated, whereas acyl-alkyl-containing phosphatidylcholines and alkylglyceronephosphate synthase levels were elevated in INRs. Evidence that elite controllers harbor an inborn error of metabolism (late-onset multiple acyl-coenzyme A dehydrogenase deficiency [MADD]) was detected. Blood-based markers from metabolomics show a very high accuracy of discriminating HIV infection between varieties of controls and have the ability to predict rapid disease progression or poor antiretroviral immunological response. These metabolites can be used as biomarkers of HIV natural evolution or treatment response and provide insight into the mechanisms of the disease.
Coetzee, J F; Gehring, R; Bettenhausen, A C; Lubbers, B V; Toerber, S E; Thomson, D U; Kukanich, B; Apley, M D
2007-08-01
Pain associated with castration in cattle is an animal welfare concern in beef production. This study examined the effect of oral aspirin and intravenous (i.v.) sodium salicylate on acute plasma cortisol response following surgical castration. Twenty bulls, randomly assigned to the following groups, (i) uncastrated, untreated controls, (ii) castrated, untreated controls, (iii) 50 mg/kg sodium salicylate i.v. precastration and (iv) 50 mg/kg aspirin (acetylsalicylic acid) per os precastration, were blood sampled at 3, 10, 20, 30, 40, 50 min and 1, 1.5, 2, 4, 6, 8, 10 and 12 h postcastration. Samples were analyzed by competitive chemiluminescent immunoassay and fluorescence polarization immunoassay for cortisol and salicylate, respectively. Data were analyzed using noncompartmental analysis, a simple cosine model, anova and t-tests. Intravenous salicylate V(d(ss)) was 0.18 L/kg, Cl(B) was 3.36 mL/min/kg and t(1/2 lambda) was 0.63 h. Plasma salicylate concentrations above 25 microg/mL coincided with significant attenuation in peak cortisol concentrations (P = 0.029). Peak salicylate concentrations following oral aspirin administration was <10 microg/mL and failed to attenuate cortisol response. Once salicylate concentrations decreased below 5 microg/mL, cortisol response in the castrated groups was significantly higher than uncastrated controls (P = 0.018). These findings have implications for designing drug regimens to provide analgesia during routine animal husbandry procedures.
Höglund, E; Kolm, N; Winberg, S
2001-10-01
Arctic charr (Salvelinus alpinus) were tested for aggressive behavior using intruder tests, before and after 2 days of dyadic social interaction. Following social interaction, half of the dominant and half of the subordinate fish were given L-DOPA (10 mg/kg, orally), whereas the remaining dominant and subordinate fish were given vehicle. One hour following drug treatment, the fish were tested for aggressive behavior again in a third and final intruder test, after which blood plasma and brain tissue were sampled for analysis of plasma cortisol concentrations and brain levels of monoamines and monoamine metabolites. Subordinate fish showed a reduction in the number of attacks launched against the intruder, as well as an increase in attack latency, as compared to prior to dyadic social interactions. Social subordination also resulted in an elevation of brain serotonergic activity. Fish receiving L-DOPA prior to the final intruder test showed shorter attack latency than vehicle controls. Drug treatment was a stressful experience and vehicle controls showed elevated plasma cortisol levels and longer attack latency as compared to before treatment. L-DOPA-treated fish showed lower plasma levels of cortisol and lower serotonergic activity in certain brain areas than vehicle controls. These results suggest that L-DOPA counteracts the stress-induced inhibition of aggressive behavior, and at the same time inhibits stress-induced effects on brain serotonergic activity and plasma cortisol concentrations.
Kassem, Amira Abdulbari; Abu Bakar, Md Zuki; Yong Meng, Goh; Mustapha, Noordin Mohamed
2012-01-01
The objective of this paper is to study the effects of varying dietary levels of n-6 : n-3 fatty acid ratio on plasma and tissue fatty acid composition in rat. The treatment groups included control rats fed chow diet only, rats fed 50% soybean oil (SBO): 50% cod liver oil (CLO) (1 : 1), 84% SBO: 16% CLO (6 : 1), 96% SBO: 4% CLO (30 : 1). Blood samples were taken at day 15 of pregnancy, and the plasma and tissue were analyzed for fatty acid profile. The n-3 PUFA in plasma of Diet 1 : 1 group was significantly higher than the other diet groups, while the total n-6 PUFA in plasma was significantly higher in Diet 30 : 1 group as compared to the control and Diet 1 : 1 groups. The Diet 1 : 1 group showed significantly greater percentages of total n-3 PUFA and docosahexaenoic acid in adipose and liver tissue, and this clearly reflected the contribution of n-3 fatty acids from CLO. The total n-6 PUFA, linoleic acid, and arachidonic acid were significantly difference in Diet 30 : 1 as compared to Diet 1 : 1 and control group. These results demonstrated that the dietary ratio of n-6 : n-3 fatty acid ratio significantly affected plasma and tissue fatty acids profile in pregnant rat. PMID:22489205
Croteau, David; Letendre, Scott; Best, Brookie M.; Ellis, Ronald J.; Breidinger, Sheila; Clifford, David; Collier, Ann; Gelman, Benjamin; Marra, Christina; Mbeo, Gilbert; McCutchan, Allen; Morgello, Susan; Simpson, David; Way, Lauren; Vaida, Florin; Ueland, Susan; Capparelli, Edmund; Grant, Igor
2010-01-01
HIV-associated neurocognitive disorders continue to be common. Antiretrovirals that achieve higher concentrations in cerebrospinal fluid (CSF) are associated with better control of HIV and improved cognition. The objective of this study was to measure total raltegravir (RAL) concentrations in CSF and to compare them with matched concentrations in plasma and in vitro inhibitory concentrations. Eighteen subjects with HIV-1 infection were enrolled based on the use of RAL-containing regimens and the availability of CSF and matched plasma samples. RAL was measured in 21 CSF and plasma pairs by liquid chromatography-tandem mass spectrometry, and HIV RNA was detected by reverse transcription-PCR (RT-PCR). RAL concentrations were compared to the 50% inhibitory concentration (IC50) for wild-type HIV-1 (3.2 ng/ml). Volunteers were predominantly middle-aged white men with AIDS and without hepatitis C virus (HCV) coinfection. The median concurrent CD4+ cell count was 276/μl, and 28% of CD4+ cell counts were below 200/μl. HIV RNA was detectable in 38% of plasma specimens and 4% of CSF specimens. RAL was present in all CSF specimens, with a median total concentration of 14.5 ng/ml. The median concentration in plasma was 260.9 ng/ml, with a median CSF-to-plasma ratio of 0.058. Concentrations in CSF correlated with those in with plasma (r2, 0.24; P, 0.02) but not with the postdose sampling time (P, >0.50). RAL concentrations in CSF exceeded the IC50 for wild-type HIV in all specimens by a median of 4.5-fold. RAL is present in CSF and reaches sufficiently high concentrations to inhibit wild-type HIV in all individuals. As a component of effective antiretroviral regimens or as the main antiretroviral, RAL likely contributes to the control of HIV replication in the nervous system. PMID:20876368
Sterilization of Turmeric by Atmospheric Pressure Dielectric Barrier Discharge Plasma
NASA Astrophysics Data System (ADS)
Setareh, Salarieh; Davoud, Dorranian
2013-11-01
In this study atmospheric pressure dielectric barrier discharge (DBD) plasma has been employed for sterilizing dry turmeric powders. A 6 kV, 6 kHz frequency generator was used to generate plasma with Ar, Ar/O2, He, and He/O2 gases between the 5 mm gap of two quartz covered electrodes. The complete sterilization time of samples due to plasma treatment was measured. The most important contaminant of turmeric is bacillus subtilis. The results show that the shortest sterilization time of 15 min is achieved by exposing the samples to Ar/O2 plasma. Survival curves of samples are exponential functions of time and the addition of oxygen to plasma leads to a significant increase of the absolute value of time constant of the curves. Magnitudes of protein and DNA in treated samples were increased to a similar value for all samples. Taste, color, and solubility of samples were not changed after the plasma treatment.
Automated standardization technique for an inductively-coupled plasma emission spectrometer
Garbarino, John R.; Taylor, Howard E.
1982-01-01
The manifold assembly subsystem described permits real-time computer-controlled standardization and quality control of a commercial inductively-coupled plasma atomic emission spectrometer. The manifold assembly consists of a branch-structured glass manifold, a series of microcomputer-controlled solenoid valves, and a reservoir for each standard. Automated standardization involves selective actuation of each solenoid valve that permits a specific mixed standard solution to be pumped to the nebulizer of the spectrometer. Quality control is based on the evaluation of results obtained for a mixed standard containing 17 analytes, that is measured periodically with unknown samples. An inaccurate standard evaluation triggers restandardization of the instrument according to a predetermined protocol. Interaction of the computer-controlled manifold assembly hardware with the spectrometer system is outlined. Evaluation of the automated standardization system with respect to reliability, simplicity, flexibility, and efficiency is compared to the manual procedure. ?? 1982.
Zhang, Lijun; Jia, Xiaofang; Peng, Xia; Ou, Qiang; Zhang, Zhengguo; Qiu, Chao; Yao, Yamin; Shen, Fang; Yang, Hua; Ma, Fang; Wang, Jiefei; Yuan, Zhenghong
2010-10-01
This paper presents an liquid chromatography (LC)/mass spectrometry (MS)-based metabonomic platform that combined the discovery of differential metabolites through principal component analysis (PCA) with the verification by selective multiple reaction monitoring (MRM). These methods were applied to analyze plasma samples from liver disease patients and healthy donors. LC-MS raw data (about 1000 compounds), from the plasma of liver failure patients (n = 26) and healthy controls (n = 16), were analyzed through the PCA method and a pattern recognition profile that had significant difference between liver failure patients and healthy controls (P < 0.05) was established. The profile was verified in 165 clinical subjects. The specificity and sensitivity of this model in predicting liver failure were 94.3 and 100.0%, respectively. The differential ions with m/z of 414.5, 432.0, 520.5, and 775.0 were verified to be consistent with the results from PCA by MRM mode in 40 clinical samples, and were proved not to be caused by the medicines taken by patients through rat model experiments. The compound with m/z of 520.5 was identified to be 1-Linoleoylglycerophosphocholine or 1-Linoleoylphosphatidylcholine through exact mass measurements performed using Ion Trap-Time-of-Flight MS and METLIN Metabolite Database search. In all, it was the first time to integrate metabonomic study and MRM relative quantification of differential peaks in a large number of clinical samples. Thereafter, a rat model was used to exclude drug effects on the abundance of differential ion peaks. 1-Linoleoylglycerophosphocholine or 1-Linoleoylphosphatidylcholine, a potential biomarker, was identified. The LC/MS-based metabonomic platform could be a powerful tool for the metabonomic screening of plasma biomarkers.
Diao, Xingxing; Ma, Zhiyu; Lei, Peng; Zhong, Dafang; Zhang, Yifan; Chen, Xiaoyan
2013-11-15
A novel and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated to determine the exposure of 3-n-butylphthalide (NBP) enantiomers in human plasma. The NBP enantiomers were extracted from human plasma using methyl tert-butyl ether. The baseline separation of R-(+)-NBP and S-(-)-NBP was achieved within 11.0min using a teicoplanin-based Astec Chirobiotic T column (250mm×4.6mm i.d., 5μm) under isocratic conditions at a flow rate of 0.6mL/min. The selection of the chiral stationary phase and the effect of the mobile phase composition on the resolution of the enantiomers were discussed. The selectivity, linearity, precision, accuracy, matrix effect, recovery, and stability were evaluated under optimized conditions. The LC-MS/MS method using 200μL of human plasma was linear over the concentration range of 5.00-400ng/mL for each enantiomer. The lower limit of quantification (LLOQ) for both enantiomers was 5.00ng/mL. The intra- and inter-assay precision values of the replicated quality control samples were within 8.0% for each enantiomer. The mean accuracy values for the quality control samples were within ±6.1% of the nominal values for R-(+)-NBP and S-(-)-NBP. No chiral inversion was observed during sample storage, preparation, and analysis. The method proved suitable for enantioselective pharmacokinetic studies of NBP after an oral administration of a therapeutic dose of racemic NBP. Copyright © 2013 Elsevier B.V. All rights reserved.
Felten, Sandra; Leutenegger, Christian M; Balzer, Hans-Joerg; Pantchev, Nikola; Matiasek, Kaspar; Wess, Gerhard; Egberink, Herman; Hartmann, Katrin
2017-08-02
Feline coronavirus (FCoV) exists as two pathotypes, and FCoV spike gene mutations are considered responsible for the pathotypic switch in feline infectious peritonitis (FIP) pathogenesis. The aim of this study was to evaluate sensitivity and specificity of a real-time reverse transcriptase polymerase chain reaction (RT-PCR) specifically designed to detect FCoV spike gene mutations at two nucleotide positions. It was hypothesized that this test would correctly discriminate feline infectious peritonitis virus (FIPV) and feline enteric coronavirus (FECV). The study included 63 cats with signs consistent with FIP. FIP was confirmed in 38 cats. Twenty-five control cats were definitively diagnosed with a disease other than FIP. Effusion and/or serum/plasma samples were examined by real-time RT-PCR targeting the two FCoV spike gene fusion peptide mutations M1058 L and S1060A using an allelic discrimination approach. Sensitivity, specificity, negative and positive predictive values including 95% confidence intervals (95% CI) were calculated. FIPV was detected in the effusion of 25/59 cats, one of them being a control cat with chronic kidney disease. A mixed population of FIPV/FECV was detected in the effusion of 2/59 cats; all of them had FIP. RT-PCR was negative or the pathotype could not be determined in 34/59 effusion samples. In effusion, sensitivity was 68.6% (95% CI 50.7-83.2), specificity was 95.8% (95% CI 78.9-99.9). No serum/plasma samples were positive for FIPV. Although specificity of the test in effusions was high, one false positive result occurred. The use of serum/plasma cannot be recommended due to a low viral load in blood.
Abdeldaim, G; Herrmann, B; Mölling, P; Holmberg, H; Blomberg, J; Olcén, P; Strålin, K
2010-08-01
In the present study, we evaluated rapid real-time PCR assays for ply, Spn9802, and lytA applied to plasma samples for the detection of Streptococcus pneumoniae in patients with community-acquired pneumonia (CAP). In a prospective study of CAP aetiology, an EDTA plasma sample was collected together with blood culture in 92 adult CAP patients and 91 adult controls. Among the 92 CAP patients, lytA PCR was positive in eight (9%), Spn9802 PCR was positive in 11 (12%) and ply PCR was positive in 19 (21%) cases. Of 91 controls, the ply PCR was positive in eight cases (9%), but no positive cases were noted by Spn9802 or lytA PCRs. Ten CAP patients had pneumococcal bacteraemia. Compared to blood culture, PCR for lytA, Spn9802 and ply had sensitivities of 70% (7/10), 60% (6/10) and 70% (7/10), and specificities of 96% (79/82), 94% (77/82) and 85% (70/82) respectively. With blood culture and/or culture of representative sputum, and/or urinary antigen detection, S. pneumoniae was identified in 31 CAP patients. Compared to these tests in combination, PCR for lytA, Spn9802 and ply showed sensitivities of 26% (8/31), 32% (10/31) and 42% (13/31), and specificities of 100% (61/61), 98% (60/61) and 90% (55/61) respectively. We conclude that Spn9802 and lytA PCRs may be useful for the rapid detection of bacteraemic pneumococcal pneumonia, whereas ply PCR is not specific enough for routine use and blood PCR with small plasma volumes is not useful for the detection of nonbacteraemic pneumococcal pneumonia.
Misaizu, T; Matsuki, S; Strickland, T W; Takeuchi, M; Kobata, A; Takasaki, S
1995-12-01
To elucidate the role of the branched structure of sugar chains of human erythropoietin (EPO) in the expression of in vivo activity, the pharmacokinetic profile of a less active recombinant human EPO sample (EPO-bi) enriched with biantennary sugar chains was compared with that of a highly active control EPO sample enriched with tetraantennary sugar chains. After an intravenous injection in rats, 125I-EPO-bi disappeared from the plasma with 3.2 times greater total body clearance (Cltot) than control 125I-EPO. Whole-body autoradiography after 20 minutes of administration indicated that the overall distribution of radioactivity is similar, but 125I-EPO-bi showed a higher level of radioactivity in the kidneys than control 125I-EPO. Quantitative determination of radioactivity in the tissues also indicated that radioactivity of 125I-EPO-bi in the kidneys was two times higher than that of control 125I-EPO. The difference in plasma disappearance between 125I-EPO-bi and control 125I-EPO was not observed in bilaterally nephrectomized rats. The distribution of 125I-EPO-bi to bone marrow and spleen was similarly inhibited by simultaneous injection of excess amounts of either the nonlabeled EPO-bi or control EPO. These results indicate that the low in vivo biologic activity of EPO-bi results from rapid clearance from the systemic circulation by renal handling. Thus, the well-branched structure of the N-linked sugar chain of EPO is suggested to play an important role in maintaining its higher plasma level, which guarantees an effective transfer to target organs and stimulation of erythroid progenitor cells.
Clinical Implication of Plasma Hydrogen Sulfide Levels in Japanese Patients with Type 2 Diabetes.
Suzuki, Kunihiro; Sagara, Masaaki; Aoki, Chie; Tanaka, Seiichi; Aso, Yoshimasa
Objective The goal of the present study was to investigate the plasma hydrogen sulfide (H 2 S) levels in patients with type 2 diabetes, as the plasma H 2 S levels in Japanese patients with type 2 diabetes remain unclear. Methods The plasma H 2 S levels were measured in 154 outpatients with type 2 diabetes and 66 outpatients without diabetes. All blood samples were collected in the outpatient department from 09:00 to 10:00. The patients had fasted from 21:00 the previous evening and had not consumed alcohol or caffeine or smoked until sample collection. The plasma H 2 S levels were measured using the methylene blue assay. The plasma H 2 S levels were determined in triplicate, and the average concentrations were calculated against a calibration curve of sodium sulfide. Results The patients with type 2 diabetes showed a progressive reduction in the plasma H 2 S levels (45.115.5 M versus 54.026.4 M, p<0.05), which paralleled poor glycemic control. There was a significant correlation between a reduction in the plasma H 2 S levels and the HbA1c levels (=-0.505, p<0.01), Furthermore, a reduction in the plasma H 2 S levels was found to be related to a history of cardiovascular diseases in patients with type 2 diabetes (39.913.8 M versus 47.515.9 M, p<0.01). Conclusion Collectively, the plasma H 2 S levels were reduced in patients with type 2 diabetes, which may have implications in the pathophysiology of cardiovascular disease in diabetic patients. The trial was registered with the University Hospital Medical Information Network (UMIN no. #000020549).
Diallo, Karidia; Lehotzky, Erica; Zhang, Jing; Zhou, Zhiyong; de Rivera, Ivette Lorenzana; Murillo, Wendy E; Nkengasong, John; Sabatier, Jennifer; Zhang, Guoqing; Yang, Chunfu
2014-01-01
Whatman 903 filter paper is the only filter paper that has been used for HIV drug resistance (HIVDR) genotyping in resource-limited settings. In this study, we evaluated another dried blood specimen collection device, termed SampleTanker(®) (ST), for HIVDR genotyping. Blood specimens from 123 antiretroviral therapy (ART)-experienced patients were used to prepare ST whole blood and ST plasma specimens; they were then stored at ambient temperature for 2 or 4 weeks. The remaining plasma specimens were stored at -80°C and used as frozen plasma controls. Frozen plasma viral load (VL) was determined using the Roche Amplicor HIV-1 Monitor test, v.1.5 and 50 specimens with VL ≥3.00 log10 copies/ml were genotyped using the broadly sensitive genotyping assay. The medium VL for the 50 frozen plasma specimens with VL ≥3.00 log10 was 3.58 log10 copies/ml (IQR: 3.32-4.11) and 96.0% (48/50) of them were genotyped. Comparing to frozen plasma specimens, significantly lower genotyping rates were obtained from ST whole blood (48.98% and 42.85%) and ST plasma specimens (36.0% and 36.0%) stored at ambient temperature for 2 and 4 weeks, respectively (p<0.001). Nucleotide sequence identity and resistance profile analyses between the matched frozen plasma and ST whole blood or ST plasma specimens revealed high nucleotide sequence identities and concordant resistance profiles (98.1% and 99.0%, and 96.6% and 98.9%, respectively). Our results indicate that with the current design, the ST may not be the ideal dried blood specimen collection device for HIVDR monitoring for ART patients in resource-limited settings.
Periodic upright posture negates the suppression of neuroendocrine response to head down bedrest
NASA Technical Reports Server (NTRS)
Wade, C. E.; Vernikos, J.; Evans, J.; Ohara, D.
1992-01-01
Head down bedrest (HDT) decreases plasma neurohormone levels, attaining a nadir within four hours. The present study evaluates the effect of periodic standing or exercises (+G(z)) on this acute suppression of plasma neurohormones. Methods: Nine male subjects (mean plus or minus SE age 37 plus or minus 2 yr; height 182 plus or minus 2 cm; weight 83 plus or minus 3 kg) were admitted to the Human Research Facility on three occasions separated by one month. Subjects were assigned to head down tilt (minus 6 degrees) or 15-minutes of standing or moderate exercise at the end of each hour. Initially during an ambulatory period, subjects were placed in a supine position for 45-min and a control blood sample obtained. The next day following 4 hours of HDT with or without standing or exercise a blood sample was taken 45-min (3 3/4 hours into HDT) after the preceding stand or exercise. Blood was withdrawn and all plasma samples frozen for determination of neurohormone levels within the same assay. Plasma aldosterone, Plasma Renin Activity (PRA) vasopressin (AVP) and cortisol levels were measured by radioimmunoassay. Norepinephrine (NE) and epinephrine (E) levels were measured by electrochemical detection following HPLC. Values were compared by ANOVA, P less than 0.05. Results: Control levels following 45-min supine were not different between treatments. HDT suppressed plasma aldosterone (13.9 plus or minus 3.7 to 6.6 plus or minus 0.7 ng/dl) and NE levels (299 plus or minus 35 to 217 plus or minus 23 pg/dl), E (69 plus or minus 15 to 65 plus or minus 21 pg/ml), and PRA (0.64 plus or minus 0.13 to 0.58 plus or minus 0.17 ngAl/m/hr) were not significantly altered. Standing or exercise negated the decrease in aldosterone and NE levels due to HDT. Conclusions: Periodic upright posture (+G(z)) with or without exercise for 15-min out of each hour negates the acute suppression of aldosterone and NE associated with HDT.
Markus, C Rob; Sierksma, Aafje; Verbeek, Cees; van Rooijen, Jan J M; Patel, Hamina J; Brand, A Nico; Hendriks, Henk F J
2004-12-01
Brain serotonin (5-HT) synthesis is controlled by nutrients that influence the availability of plasma tryptophan (Trp) as compared with the sum of the other large neutral amino acids (LNAA; Trp:LNAA). Alcohol consumption is found to change mood and performance and this might well be due to alterations in the plasma Trp:LNAA ratio and brain 5-HT. In the present study, we tested whether whisky consumption as part of a meal may alter the plasma Trp:LNAA ratio and influence mood and performance in healthy volunteers. Twenty-four healthy male subjects participated in a within-subjects cross-over study. Subjects consumed whisky (125 ml; 40 g alcohol) or water (125 ml) as part of a standard evening meal. Effects of whisky consumption were tested on mood and choice reaction time and blood samples were taken to measure changes in plasma amino acids, glucose and insulin. The plasma Trp:LNAA ratio showed a significant decline 2 h after whisky consumption of alcohol (P<0.001). No effects were found on choice reaction time or mood as compared with the control condition. The present findings reveal that whisky consumption alters available plasma Trp for uptake into the brain, whereas there were no effects on mood and performance.
Pilny, Anthony A; Quesenberry, Katherine E; Bartick-Sedrish, Tracey E; Latimer, Kenneth S; Berghaus, Roy D
2012-06-15
To determine whether the presence of Chlamydophila psittaci antigen, plasma cholesterol concentration, diet, sex, species, and age are risk factors for the development of atherosclerosis in pet psittacine birds. Retrospective case-control study. 31 psittacine birds with atherosclerosis (study birds) and 31 psittacine birds without atherosclerosis (control birds). Necropsy reports were reviewed, birds with a histopathologic diagnosis of atherosclerosis were identified, and available medical records were reviewed. Signalment, history, clinicopathologic findings, and other relevant data were recorded and evaluated. Control birds did not have atherosclerosis and were chosen by both convenience sampling and population demographics. Histologic sections of great vessels from all birds (study and control birds) were reviewed and then submitted for immunohistochemical staining for the presence of C psittaci antigen. Result of immunohistochemical staining for C psittaci antigen in blood vessels was significantly associated with atherosclerosis. After adjusting for age, species origin, and type of illness, the odds of atherosclerosis was 7 times as high for birds with positive immunohistochemical staining for C psittaci antigen, compared with that of birds with negative immunohistochemical staining. Study birds and control birds differed significantly only with respect to plasma cholesterol concentrations. The median plasma cholesterol concentration of study birds (421 mg/dL) was significantly higher than that of control birds (223 mg/dL). Infection with C psittaci and a high plasma cholesterol concentration may be risk factors for developing atherosclerosis in pet psittacine birds.
Schwertner, Harvey A; Kong, Suk Bin
2005-03-09
Modafinil (Provigil) is a new wake-promoting drug that is being used for the management of excessive sleepiness in patients with narcolepsy. It has pharmacological properties similar to that of amphetamine, but without some of the side effects associated with amphetamine-like stimulants. Since modafinil has the potential to be abused, accurate drug-screening methods are needed for its analysis. In this study, we developed a high-performance liquid-chromatographic procedure (HPLC) for the quantitative analysis of modafinil in plasma and urine. (Phenylthio)acetic acid was used as an internal standard for the analysis of both plasma and urine. Modafinil was extracted from urine and plasma with ethyl acetate and ethyl acetate-acetic acid (100:1, v/v), respectively, and analyzed on a C18 reverse phase column with methanol-water-acetic acid (500:500:1, v/v) as the mobile phase. Recoveries from urine and plasma were 80.0 and 98.9%, respectively and the limit of quantitation was 0.1 microg/mL at 233 nm. Forty-eight 2-h post-dose urine samples from sham controls and from individuals taking 200 or 400 mg of modafinil were analyzed without knowledge of drug administration. All 16-placebo urine samples and all 32 2-h post-dose urine samples were correctly classified. The analytical procedure is accurate and reproducible and can be used for therapeutic drug monitoring, pharmacokinetic studies, and drug abuse screening.
Ahn, Yeong Hee; Shin, Park Min; Oh, Na Ree; Park, Gun Wook; Kim, Hoguen; Yoo, Jong Shin
2012-09-18
Aberrantly glycosylated proteins related to liver cancer progression were captured with specific lectin and identified from human plasma by multiple reaction monitoring (MRM) mass spectrometry as multiple biomarkers for hepatocellular carcinoma (HCC). The lectin fractionation for fucosylated protein glycoforms in human plasma was conducted with a fucose-specific aleuria aurantia lectin (AAL). Following tryptic digestion of the lectin-captured fraction, plasma samples from 30 control cases (including 10 healthy, 10 hepatitis B virus [HBV], and 10 cirrhosis cases) and 10 HCC cases were quantitatively analyzed by MRM to identify which glycoproteins are viable HCC biomarkers. A1AG1, AACT, A1AT, and CERU were found to be potent biomarkers to differentiate HCC plasma from control plasmas. The AUROC generated independently from these four biomarker candidates ranged from 0.73 to 0.92. However, the lectin-coupled MRM assay with multiple combinations of biomarker candidates is superior statistically to those generated from the individual candidates with AUROC more than 0.95, which can be an alternative to the immunoassay inevitably requiring tedious development of multiple antibodies against biomarker candidates to be verified. Eventually the lectin-coupled, targeted proteomic mass spectrometry (MRM MS) platform was found to be efficient to identify multiple biomarkers from human plasma according to cancer progression. Copyright © 2012 Elsevier B.V. All rights reserved.
Image-guided plasma therapy of cutaneous wound
NASA Astrophysics Data System (ADS)
Zhang, Zhiwu; Ren, Wenqi; Yu, Zelin; Zhang, Shiwu; Yue, Ting; Xu, Ronald
2014-02-01
The wound healing process involves the reparative phases of inflammation, proliferation, and remodeling. Interrupting any of these phases may result in chronically unhealed wounds, amputation, or even patient death. Despite the clinical significance in chronic wound management, no effective methods have been developed for quantitative image-guided treatment. We integrated a multimodal imaging system with a cold atmospheric plasma probe for image-guided treatment of chronic wound. Multimodal imaging system offers a non-invasive, painless, simultaneous and quantitative assessment of cutaneous wound healing. Cold atmospheric plasma accelerates the wound healing process through many mechanisms including decontamination, coagulation and stimulation of the wound healing. The therapeutic effect of cold atmospheric plasma is studied in vivo under the guidance of a multimodal imaging system. Cutaneous wounds are created on the dorsal skin of the nude mice. During the healing process, the sample wound is treated by cold atmospheric plasma at different controlled dosage, while the control wound is healed naturally. The multimodal imaging system integrating a multispectral imaging module and a laser speckle imaging module is used to collect the information of cutaneous tissue oxygenation (i.e. oxygen saturation, StO2) and blood perfusion simultaneously to assess and guide the plasma therapy. Our preliminary tests show that cold atmospheric plasma in combination with multimodal imaging guidance has the potential to facilitate the healing of chronic wounds.
Dust remobilization in fusion plasmas under steady state conditions
NASA Astrophysics Data System (ADS)
Tolias, P.; Ratynskaia, S.; De Angeli, M.; De Temmerman, G.; Ripamonti, D.; Riva, G.; Bykov, I.; Shalpegin, A.; Vignitchouk, L.; Brochard, F.; Bystrov, K.; Bardin, S.; Litnovsky, A.
2016-02-01
The first combined experimental and theoretical studies of dust remobilization by plasma forces are reported. The main theoretical aspects of remobilization in fusion devices under steady state conditions are analyzed. In particular, the dominant role of adhesive forces is highlighted and generic remobilization conditions—direct lift-up, sliding, rolling—are formulated. A novel experimental technique is proposed, based on controlled adhesion of dust grains on tungsten samples combined with detailed mapping of the dust deposition profile prior and post plasma exposure. Proof-of-principle experiments in the TEXTOR tokamak and the EXTRAP-T2R reversed-field pinch are presented. The versatile environment of the linear device Pilot-PSI allowed for experiments with different magnetic field topologies and varying plasma conditions that were complemented with camera observations.
Characterization of a low pressure supersonic plasma jet
NASA Astrophysics Data System (ADS)
Caldirola, S.; Barni, R.; Riccardi, C.
2014-11-01
Plasma assisted supersonic jet deposition (PA-SJD) is a technique which combines a inductively coupled plasma (ICP) with a supersonic jet for the fabrication of thin films having a desired morphology. A reactive argon-oxygen plasma is employed to dissociate an organic precursor (titanium tetra-isopropoxide for TiO2 thin films) in a first vacuum chamber which is connected through a nozzle to a lower pressure chamber. The pressure difference produces a supersonic jet, seeded with nanoparticles. Along the jet the nucleation and aggregation of nanoparticles can be controlled to obtain nanostructured depositions. We report here the results of an analysis performed with a quadrupole mass spectrometer (QMS) which was used to sample neutrals and ions from the jet at different positions along the centerline of the supersonic expansion.
Marsot, Amélie; Audebert, Christine; Attolini, Laurence; Lacarelle, Bruno; Micallef, Joelle; Blin, Olivier
A randomized cross-over, double blind placebo controlled study of smoked cannabis was carried out on occasional cannabis smokers. The objective of this research was to describe the pharmacokinetic parameters of THC and its metabolites in plasma, oral fluid and urine, from samples obtained simultaneously to provide estimations of THC and metabolites concentrations after smoking a cannabis cigarette. Blood, oral fluid and urine samples were collected until up to 72 h after smoking the cannabis cigarette (4% of delta-9-tetrathydrocannabinol (THC)). THC, 11-OH-THC and THC-COOH were analyzed by gas-chromatography-mass spectrometry. Pharmacokinetic parameters were estimated from these data. Eighteen male healthy adults participated in the study. In total, 560 plasma, 288 oral fluid and 448 urine samples were quantified for cannabinoids. Plasma, oral fluid and urine pharmacokinetic parameters were calculated. A wide range of median THC Cmax (1.6-160.0 µg/L and 55.4-123120.0 µg/L in plasma and oral fluid, respectively), 11-OH-THC Cmax (0-11.1 µg/L in plasma) and THC-COOH Cmax (1.0-56.3 µg/L in plasma) was observed. When expressed as a percentage of the total available THC dose, and corrected for molar equivalents, mean percentage of total THC dose excreted was 1.9 +/-2.5 % with range of 0.2-7.5%. This high inter-individual variability was also observed on other calculated pharmacokinetic parameters. Prediction of plasma THC concentration from THC oral fluid concentration or from THC-COOH urinary concentrations is not feasible due to the large variations observed. The results from this study support the assumption that a positive oral fluid THC result or a positive urine fluid result are indicative of a recent cannabis exposure. This article is open to POST-PUBLICATION REVIEW. Registered readers (see "For Readers") may comment by clicking on ABSTRACT on the issue's contents page.
Jiang, Hongliang; Li, Yinghe; Pelzer, Mary; Cannon, Michelle J; Randlett, Christopher; Junga, Heiko; Jiang, Xiangyu; Ji, Qin C
2008-05-30
A sensitive and selective bioanalytical assay was developed and validated for the determination of enantiomeric molindone in human plasma using high-performance liquid chromatography-tandem mass spectrometry along with supported liquid extraction procedures. The chiral separation was evaluated and optimized on macrocyclic antibiotic type chiral stationary phases (CSPs) based on teicoplanin aglycone (Chirobiotic TAG) in polar organic, polar ionic, and reversed-phase mode chromatography, respectively. Complete baseline separation was achieved on a Chirobiotic TAG column under isocratic condition in reversed-phase chromatography. The method validation was conducted using a Chirobiotic TAG column (100 mm x 2.1 mm) over the curve range 0.100-100 ng/ml for each molindone enantiomer using 0.0500 ml of plasma sample. The flow rate was 0.8 ml/min and the total run time was 9 min. Supported liquid extraction in a 96-well plate format was used for sample preparation. Parameters including recovery, matrix effect, linearity, sensitivity, specificity, carryover, precision, accuracy, dilution integrity, and stability were evaluated. The intra- and inter-day precision and accuracy of the quality control samples at low, medium, and high concentration levels were RSD
García-Martínez, D; Rupérez, F J; Ugarte, P; Barbas, C
2007-07-01
Streptozotocin-induced diabetic rats constitute a model of oxidative stress, and vitamin E continues to be a topic of speculation in this area. On the other hand, marine extracts, particularly microalgae extracts obtained with environmentally clean technologies and which demonstrate antioxidant activity in vitro, are a potential source of in vivo antioxidant defense. We have studied the alpha-tocopherol content in the plasma and liver of diabetic rats after 7 and 14 days under the condition, and before and after the treatment with vitamin E and C, as well as with different Spirulina extracts, as compared with the corresponding controls. The improvement of analytical methodology related to the determination of alpha-tocopherol in the plasma and liver of rats was also considered. To do this, a method previously developed for plasma, employing a single extraction step, was adapted and validated for liver after minor modifications. Moreover, stability of alpha-tocopherol in plasma of diabetic and control animals was compared in different storage conditions. Results showed that diabetic plasma strongly influences stability of alpha-tocopherol, even at -20 degrees C, but samples are stable for at least one year at -80 degrees C. Finally, regarding supplementation, results indicate that supplementation with alpha-tocopherol increases stored alpha-tocopherol in liver, but not in plasma, but this availability is strongly dependent on the stage of diabetes of the animal. Extracts of Spirulina platensis, despite showing antioxidant activity in vitro, increased alpha-tocopherol concentration in neither plasma nor liver.
Kema, I P; Meijer, W G; Meiborg, G; Ooms, B; Willemse, P H; de Vries, E G
2001-10-01
Profiling of the plasma indoles tryptophan, 5-hydroxytryptophan (5-HTP), serotonin, and 5-hydroxyindoleacetic acid (5-HIAA) is useful in the diagnosis and follow-up of patients with carcinoid tumors. We describe an automated method for the profiling of these indoles in protein-containing matrices as well as the plasma indole concentrations in healthy controls and patients with carcinoid tumors. Plasma, cerebrospinal fluid, and tissue homogenates were prepurified by automated on-line solid-phase extraction (SPE) in Hysphere Resin SH SPE cartridges containing strong hydrophobic polystyrene resin. Analytes were eluted from the SPE cartridge by column switching. Subsequent separation and detection were performed by reversed-phase HPLC combined with fluorometric detection in a total cycle time of 20 min. We obtained samples from 14 healthy controls and 17 patients with metastasized midgut carcinoid tumors for plasma indole analysis. In the patient group, urinary excretion of 5-HIAA and serotonin was compared with concentrations of plasma indoles. Within- and between-series CVs for indoles in platelet-rich plasma were 0.6-6.2% and 3.7-12%, respectively. Results for platelet-rich plasma serotonin compared favorably with those obtained by single-component analysis. Plasma 5-HIAA, but not 5-HTP was detectable in 8 of 17 patients with carcinoid tumors. In the patient group, platelet-rich plasma total tryptophan correlated negatively with platelet-rich plasma serotonin (P = 0.021; r = -0.56), urinary 5-HIAA (P = 0.003; r = -0.68), and urinary serotonin (P <0.0001; r = -0.80). The present chromatographic approach reduces analytical variation and time needed for analysis and gives more detailed information about metabolic deviations in indole metabolism than do manual, single-component analyses.
El Ati-Hellal, Myriam; Hellal, Fayçal; Hedhili, Abderrazek
2014-10-01
The aim of this study was the optimization of selenium determination in plasma samples with electrothermal atomic absorption spectrometry using experimental design methodology. 11 variables being able to influence selenium analysis in human blood plasma by electrothermal atomic absorption spectrometry (ETAAS) were evaluated with Plackett-Burman experimental design. These factors were selected from sample preparation, furnace program and chemical modification steps. Both absorbance and background signals were chosen as responses in the screening approach. Doehlert design was used for method optimization. Results showed that only ashing temperature has a statistically significant effect on the selected responses. Optimization with Doehlert design allowed the development of a reliable method for selenium analysis with ETAAS. Samples were diluted 1/10 with 0.05% (v/v) TritonX-100+2.5% (v/v) HNO3 solution. Optimized ashing and atomization temperatures for nickel modifier were 1070°C and 2270°C, respectively. A detection limit of 2.1μgL(-1) Se was obtained. Accuracy of the method was checked by the analysis of selenium in Seronorm™ Trace element quality control serum level 1. The developed procedure was applied for the analysis of total selenium in fifteen plasma samples with standard addition method. Concentrations ranged between 24.4 and 64.6μgL(-1), with a mean of 42.6±4.9μgL(-1). The use of experimental designs allowed the development of a cheap and accurate method for selenium analysis in plasma that could be applied routinely in clinical laboratories. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Identifying potential markers in Breast Cancer subtypes using plasma label-free proteomics.
Corrêa, Stephany; Panis, Carolina; Binato, Renata; Herrera, Ana Cristina; Pizzatti, Luciana; Abdelhay, Eliana
2017-01-16
Breast Cancer (BC) is the most common neoplasia among women and has a high mortality rate worldwide. Over the past several decades, increasing molecular knowledge of BC has resulted in its stratification into 4 major molecular subtypes according to hormonal receptor expression. Unfortunately, although the data accumulated thus far has improved BC prognosis and treatment, there have been few achievements in its diagnosis. In this study, we applied a Label-free Nano-LC/MSMS approach to reveal systemic molecular features and possible plasma markers for BC patients. Compared to healthy control plasma donors, we identified 191, 166, 182, and 186 differentially expressed proteins in the Luminal, Lumina-HER2, HER2, and TN subtypes. In silico analysis demonstrated an overall downregulation of cellular basal machinery and, more importantly, brought new focus to the known pathways and signaling molecules in BC that are related to immune system alterations. Moreover, using western blot analysis, we verified high levels of BCAS3, IRX1, IRX4 and IRX5 in BC plasma samples, thus highlighting the potential use of plasma proteomics in investigations into cancer biomarkers. The results of this study provide new insight into Breast Cancer (BC). We determined the plasma proteomic profile of BC subtypes. Furthermore, we report that the signaling pathways correlating with late processes in BC already exhibit plasma alterations in less aggressive subtypes. Additionally, we validated the high levels of particular proteins in patient samples, which suggests the use of these proteins as potential disease markers.
Tabrizi, A Davasaz; Batavani, R A; Rezaei, S Asri; Ahmadi, M
2008-02-15
The potential using of Acute Phase Proteins (APPs) in the assessment of mammary gland health was studied by examining the levels of Fibrinogen (Fb) and Ceruloplasmin (Cp) in plasma and milk from dairy cows with different grades of mastitis. Plasma samples were taken from jugular vein and milk samples were collected from quarters of cows with subclinical and clinical mastitis, as well as healthy controls. California Mastitis Test (CMT) were performed on each udder quarter of cows for detection of CMT2+ and CMT3+ quarters. CMT (0) and culture negative cases were considered healthy cows. Clinical mastitis, was graded as mild (clots in milk) or moderate (clots in milk and visible signs of inflammation in the mammary gland/s). The concentrations of Fb in the plasma of the cows with subclinical and clinical mastitis were higher than in the plasma of the healthy cows (p<0.01). There was no significant difference in plasma concentration of Cp between healthy and subclinical groups (p>0.05), but differences between clinical and healthy groups were significant (p<0.05). The concentrations of Fb and Cp in the milk of the cows with subclinical and clinical mastitis were higher than in the milk of the healthy cows (p<0.01). The results indicated that measurement of Fb in plasma and milk and Cp only in milk might be suitable for early diagnosis of mastitis in dairy cows.
SOTOHIRA, Yukari; SUZUKI, Kazuyuki; SASAKI, Haruka; SANO, Tadashi; TSUCHIYA, Masakazu; SUZUKI, Yohko; SHIMAMORI, Toshio; TSUKANO, Kenji; SATO, Ayano; YOKOTA, Hiroshi; ASAKAWA, Mitsuhiko
2016-01-01
The aim of the present study was to evaluate the reliability and effectiveness of directly determining endotoxin activity in plasma samples from kangaroos with lumpy jaw disease (LJD, n=15) and healthy controls (n=12). Prior to the present study, the ability of the commercially available automated handheld portable test system (PTSTM) to detect endotoxin activity in kangaroo plasma was compared with that of the traditional LAL-kinetic turbidimetric (KT) assay. Plasma samples, which were obtained from endotoxin-challenged cattle, were diluted 1:20 in endotoxin-free water and heated to 80°C for 10 min. The performance of the PTSTM was not significantly different from that of the traditional LAL-based assay. The data obtained using PTSTM correlated with those using KT (r2=0.963, P<0.001). These findings indicated that the PTSTM is applicable as a simplified system to assess endotoxin activity in macropods. In the present study, we demonstrated the diagnostic value of plasma endotoxin activity in kangaroos with systemic inflammation caused by oral necrobacillosis and identified plasma endotoxin activity as a sensitive marker of systemic inflammation in kangaroos with LJD. Based on ROC curves, we proposed a diagnostic cut-off point for endotoxin activity of >0.22 EU/ml for the identification of LJD. Our results indicate that the assessment of plasma endotoxin activity is a promising diagnostic tool for determining the outcome of LJD in captive macropods. PMID:26902804
Sotohira, Yukari; Suzuki, Kazuyuki; Sasaki, Haruka; Sano, Tadashi; Tsuchiya, Masakazu; Suzuki, Yohko; Shimamori, Toshio; Tsukano, Kenji; Sato, Ayano; Yokota, Hiroshi; Asakawa, Mitsuhiko
2016-07-01
The aim of the present study was to evaluate the reliability and effectiveness of directly determining endotoxin activity in plasma samples from kangaroos with lumpy jaw disease (LJD, n=15) and healthy controls (n=12). Prior to the present study, the ability of the commercially available automated handheld portable test system (PTS(TM)) to detect endotoxin activity in kangaroo plasma was compared with that of the traditional LAL-kinetic turbidimetric (KT) assay. Plasma samples, which were obtained from endotoxin-challenged cattle, were diluted 1:20 in endotoxin-free water and heated to 80°C for 10 min. The performance of the PTS(TM) was not significantly different from that of the traditional LAL-based assay. The data obtained using PTS(TM) correlated with those using KT (r(2)=0.963, P<0.001). These findings indicated that the PTS(TM) is applicable as a simplified system to assess endotoxin activity in macropods. In the present study, we demonstrated the diagnostic value of plasma endotoxin activity in kangaroos with systemic inflammation caused by oral necrobacillosis and identified plasma endotoxin activity as a sensitive marker of systemic inflammation in kangaroos with LJD. Based on ROC curves, we proposed a diagnostic cut-off point for endotoxin activity of >0.22 EU/ml for the identification of LJD. Our results indicate that the assessment of plasma endotoxin activity is a promising diagnostic tool for determining the outcome of LJD in captive macropods.
Plasma surface cleaning in a microwave plasma source
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsai, C.C.; Nelson, W.D.; Haselton, H.H.
1994-03-01
A microwave electron cyclotron resonance (ECR) plasma source has been operated to produce reactive plasmas of oxygen and its mixture with argon. Aluminum samples (0.95 cm by 1.9 cm) were coated with thin films (<20 {mu}m in thickness) of Shell Vitrea oil and cleaned by using such reactive plasmas. The plasma cleaning was done in discharge conditions of microwave power up to 1300 W, radio frequency power up to 200 W, biased potential up to 400 V, gas pressures up to 5 mtorr, and operating time up to 35 min. The surface texture of the postcleaned samples has been examinedmore » visually. Mass loss of the samples after plasma cleaning was measured to estimate cleaning rates. Measured clean rates of low-pressure (0.5-mtorr) argon/oxygen plasmas were as high as 2.7 {mu}m/min. X-ray photoelectron spectroscopy (XPS) was used to determine cleanliness of the sample surfaces after plasma cleaning. The XPS study on polished samples confirmed the effectiveness of plasma cleaning in achieving atomic level of surface cleanliness. In this technical memorandum plasma properties, cleaning phenomena, and significant results are reported and discussed.« less
Stability of Atmospheric-Pressure Plasma Induced Changes on Polycarbonate Surfaces
NASA Technical Reports Server (NTRS)
Sharma, Rajesh; Holcomb, Edward; Trigwell, Steve
2006-01-01
Polycarbonate films are subjected to plasma treatment in a number of applications such as improving adhesion between polycarbonate and silicon alloy in protective and optical coatings. The changes in surface chemistry due to plasma treatment have tendency to revert back. Thus stability of the plasma induced changes on polymer surfaces over desired time period is very important. The objective of this study was to examine the effect of ageing on atmospheric pressure helium-plasma treated polycarbonate (PC) sample as a function of treatment time. The ageing effects were studied over a period of 10 days. The samples were plasma treated for 0.5, 2, 5 and 10 minutes. Contact angle measurements were made to study surface energy changes. Modification of surface chemical structure was examined using, X-ray Photoelectron Spectroscopy (XPS). Contact angle measurements on untreated and plasma treated surfaces were made immediately, 24, 48, 72 and 96 hrs after treatment. Contact angle decreased from 93 deg for untreated sample to 30 deg for sample plasma treated for 10 minutes. After 10 days the contact angles for the 10 minute plasma treated sample increased to 67 deg, but it never reverted back to that of untreated surface. Similarly the O/C ratio increased from 0.136 for untreated sample to 0.321 for 10 minute plasma treated sample indication increase in surface energy.
Enyaru, John C.; Carr, Steven A.; Pearson, Terry W.
2013-01-01
Control of human African sleeping sickness, caused by subspecies of the protozoan parasite Trypanosoma brucei, is based on preventing transmission by elimination of the tsetse vector and by active diagnostic screening and treatment of infected patients. To identify trypanosome proteins that have potential as biomarkers for detection and monitoring of African sleeping sickness, we have used a ‘deep-mining” proteomics approach to identify trypanosome proteins in human plasma. Abundant human plasma proteins were removed by immunodepletion. Depleted plasma samples were then digested to peptides with trypsin, fractionated by basic reversed phase and each fraction analyzed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). This sample processing and analysis method enabled identification of low levels of trypanosome proteins in pooled plasma from late stage sleeping sickness patients infected with Trypanosoma brucei rhodesiense. A total of 254 trypanosome proteins were confidently identified. Many of the parasite proteins identified were of unknown function, although metabolic enzymes, chaperones, proteases and ubiquitin-related/acting proteins were found. This approach to the identification of conserved, soluble trypanosome proteins in human plasma offers a possible route to improved disease diagnosis and monitoring, since these molecules are potential biomarkers for the development of a new generation of antigen-detection assays. The combined immuno-depletion/mass spectrometric approach can be applied to a variety of infectious diseases for unbiased biomarker identification. PMID:23951171
Eyford, Brett A; Ahmad, Rushdy; Enyaru, John C; Carr, Steven A; Pearson, Terry W
2013-01-01
Control of human African sleeping sickness, caused by subspecies of the protozoan parasite Trypanosoma brucei, is based on preventing transmission by elimination of the tsetse vector and by active diagnostic screening and treatment of infected patients. To identify trypanosome proteins that have potential as biomarkers for detection and monitoring of African sleeping sickness, we have used a 'deep-mining" proteomics approach to identify trypanosome proteins in human plasma. Abundant human plasma proteins were removed by immunodepletion. Depleted plasma samples were then digested to peptides with trypsin, fractionated by basic reversed phase and each fraction analyzed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). This sample processing and analysis method enabled identification of low levels of trypanosome proteins in pooled plasma from late stage sleeping sickness patients infected with Trypanosoma brucei rhodesiense. A total of 254 trypanosome proteins were confidently identified. Many of the parasite proteins identified were of unknown function, although metabolic enzymes, chaperones, proteases and ubiquitin-related/acting proteins were found. This approach to the identification of conserved, soluble trypanosome proteins in human plasma offers a possible route to improved disease diagnosis and monitoring, since these molecules are potential biomarkers for the development of a new generation of antigen-detection assays. The combined immuno-depletion/mass spectrometric approach can be applied to a variety of infectious diseases for unbiased biomarker identification.
Steffen, Imke; Tyrrell, D. Lorne; Stein, Eleanor; Montalvo, Leilani; Lee, Tzong-Hae; Zhou, Yanchen; Lu, Kai; Switzer, William M.; Tang, Shaohua; Jia, Hongwei; Hockman, Darren; Santer, Deanna M.; Logan, Michael; Landi, Amir; Law, John; Houghton, Michael; Simmons, Graham
2011-01-01
The gammaretroviruses xenotropic murine leukemia virus (MLV)-related virus (XMRV) and MLV have been reported to be more prevalent in plasma and peripheral blood mononuclear cells of chronic fatigue syndrome (CFS) patients than in healthy controls. Here, we report the complex analysis of whole blood and plasma samples from 58 CFS patients and 57 controls from Canada for the presence of XMRV/MLV nucleic acids, infectious virus, and XMRV/MLV-specific antibodies. Multiple techniques were employed, including nested and qRT-PCR, cell culture, and immunoblotting. We found no evidence of XMRV or MLV in humans and conclude that CFS is not associated with these gammaretroviruses. PMID:22114717
Xu, Li-li; Shen, Jian-jun; Zhou, Hai-yan
2010-07-20
To investigate the effects of parecoxib sodium preemptive analgesia on perioperative cytokine responses and stress responses and postoperative analgesia in patients undergoing ophthalmology surgery. One hundred ASAI-II patients undergoing ophthalmology surgery were randomly divided into 2 groups of fifty: the parecoxib group received parecoxib 40 mg by muscle injection, the control group received an equal volume of 0.9% normal saline two ml. Venous blood samples were obtained at 10 minutes before parecoxib or 0.9% normal saline was injected (T1), 30 minutes (T2) and 60 minutes (T3) after surgery was initiated, the moment when surgery was finished (T4), 6 hours (T5), 12 hours (T6) and 24 hours (T7) after surgery was finished for determination of the plasma levels of IL-6, IL-8, IL-1RA, TNF and IL-1β. At the same time, the plasma levels of epinephrine, norepinephrine, cortisol and adrenocorticotropic hormone at T1-T6 were measured. VAS scores with patients were recorded at 1, 2, 6, 12, 24 h after surgery. The change of the plasma levels of IL-6, IL-8, IL-1RA, TNF, IL-1β in the two groups:in the parecoxib group the plasma levels of TNF and IL-1β did not decreased significantly as compared with the control group (P > 0.05). The plasma levels of IL-6, IL-8 at T4-T6 decreased significantly as compared with the control group (P < 0.01). The plasma levels of IL-1RA at T3-T6 decreased significantly as compared with the control group (P < 0.01). The change of the plasma levels of epinephrine, norepinephrine, cortisol and adrenocorticotropic hormone in the two groups:in the parecoxib group the plasma levels of epinephrine, norepinephrine at T2, T3 decreased significantly as compared with the control group (P < 0.01). In the parecoxib group the plasma levels of cortisol at T2-T4 decreased significantly as compared with the control group (P < 0.01). In the parecoxib group the plasma levels of adrenocorticotropic hormone at T2-T5 decreased significantly as compared with the control group (P < 0.01). Postoperation VAS scores:VAS scores of the parecoxib group were less than that of the control group (P < 0.05). Preoperatively-administered parecoxib during ophthalmology surgery can produce better analgesia effect, reduce the production of cytokines, decrease central nervous system sensitization so as to improve the quality of postoperative pain relief. At the same time, it can reduce perioperative stress hormone release so as to have a positive effect on post operative recovery.
Chae, Myung-Sic; Kim, Jinsik; Jeong, Dahye; Kim, YoungSoo; Roh, Jee Hoon; Lee, Sung Min; Heo, Youhee; Kang, Ji Yoon; Lee, Jeong Hoon; Yoon, Dae Sung; Kim, Tae Geun; Chang, Suk Tai; Hwang, Kyo Seon
2017-06-15
We performed oxygen plasma treatment on reduced graphene oxide (rGO) to improve its surface reactivity with respect to biomolecular interactions. Oxygen-plasma-treated rGO surfaces were employed as reactive interfaces for the detection of amyloid-beta (Aβ) peptides, the pathological hallmarks of Alzheimer's disease (AD), as the target analytes. By measuring the changes in electrical characteristics and confirmation through topographic analysis, the oxygen-plasma-treated rGO sensors had enhanced surface functionality for better antibody immobilization and sensing performance, with a 3.33-fold steeper slope for the electrical responses versus analyte concentration curve (logarithmic scale) compared to the untreated. The elicited biomolecular reactivity of the rGO surfaces with the oxygen plasma treatment remained at 46-51% of the initial value even after aging for 6h in ambient conditions. This phenomenon was also confirmed by pretreating the rGO surfaces with a blocking agent and subsequently subjecting them to antibody immobilization. Finally, the feasibility of the oxygen-plasma-treated rGO sensors as a diagnostic tool was evaluated with clinical samples of neural-derived exosomal Aβ peptides extracted from apparent AD patients and normal controls (NC). In contrast to the untreated sensors (p=0.0460), the oxygen-plasma-treated rGO sensors showed a significant p-value in the identification of clinical samples of AD and NC subjects (p<0.001). These results suggest that oxygen plasma treatment improves sensor performance without complicated fabrication procedures and should aid in the development of novel diagnostic tools based on carbon nanomaterials. Copyright © 2016 Elsevier B.V. All rights reserved.
Creation of fluorocarbon barriers on surfaces of starch-based products through cold plasma treatment
NASA Astrophysics Data System (ADS)
Han, Yousoo
Two kinds of starch foam trays (starch and aspen-starch foam trays) were produced using a lab model baking machine. Surfaces of the trays were treated with CF4 and SF6 plasma to create fluorine-rich layers on the surfaces, which might show strong water resistance. The plasma parameters, such like RF power, gas pressure and reaction time, were varied to evaluate the effects of each parameter on fluorination of surfaces. The atomic concentrations of fluorine, oxygen and carbon on samples' surfaces were earned from ESCA (electron spectroscopy for chemical analysis) and contact angles of sample surfaces were measured for hydrophobicity. For water resistance of plasma treated surfaces, liquid water uptake and water vapor uptake test were performed. Also, equilibrium moisture contents of unmodified and plasma treated samples were measured to evaluate biodegradability of plasma treated samples. Fluorine-rich barriers were created on sample surfaces treated with CF 4 and SF6 plasma. The fluorine atomic concentrations of treated sample surfaces were ranged from 34.4% to 64.4% (CF4 treatment) and 43.6% to 57.9% (SF6 treatment). It was found at both plasma gases that plasma parameters affected total fluorine concentration and carbon-peak shapes in ESCA surveys, which imply different distributions of mono- or multi-fluoro carbon's contents. In various reaction times, it was found that total fluorine contents were decreased after a critical point as the reaction time was prolonged, which may imply that a dominant mechanism has been changed from deposition or functionalization to etching. Oxygen atomic concentration was decreased at sample surfaces treated by both plasmas. In the case of SF6 plasma, it was proved that the removal of oxygen surely occurred because there was no addition of sulfur species. Plasma treated sample surfaces had high contact angles with distilled water up to 150° and the high values of angles have been kept constant up to for 15 minutes. Fluorine-rich barriers created by plasma showed lower water liquid and vapor permeability than untreated surfaces did. Plasma treated samples had similar moisture contents with untreated samples at all relative humidity tested. AFM and SEM images were taken for sample surfaces' morphology and topography.
[Expression of proBNP and NT-proBNP in Sudden Death of Coronary Heart Disease].
Zeng, Q; Sun, R F; Li, Z; Zhai, L Q; Liu, M Z; Guo, X J; Gao, C R
2017-10-01
To study the expression change of pro-brain natriuretic peptide (proBNP) and N-terminal pro-brain natriuretic peptide (NT-proBNP) in sudden death of coronary atherosclerotic heart disease, and to explore its application in forensic diagnosis. Myocardial and blood samples were collected from normal control group, sudden death of coronary atherosclerotic heart disease group and single coronary stenosis group (20 cases in each group). The expression of proBNP in myocardial samples were detected by immunohistochemical staining and Western blotting, and that of BNP mRNA were detected by reverse transcription PCR (RT-PCR). The content of NT-proBNP in plasma were detected by ELISA. Immunohistochemical staining showed positive expression of proBNP in both sudden death of coronary atherosclerotic heart disease group and single coronary stenosis group. There was no positive expression in normal control group. For sudden death of coronary atherosclerotic heart disease group and single coronary stenosis group, the relative expression of proBNP protein and BNP mRNA in myocardial tissue and the NT-proBNP content in plasma were higher than that of normal control group ( P <0.05). The NT-proBNP content in plasma of sudden death of coronary atherosclerotic heart disease group was higher than that of single coronary stenosis group ( P <0.05). In myocardial ischemia condition, the higher expression of proBNP in cardiac muscle cell shows that the detection of NT-proBNP in plasma can be useful to differentially diagnose the degree of coronary atherosclerotic heart disease and determine whether the sudden death due to coronary atherosclerotic heart disease. Copyright© by the Editorial Department of Journal of Forensic Medicine
Dalgard, C; Eidelman, O; Jozwik, C; Olsen, C H; Srivastava, M; Biswas, R; Eudy, Y; Rothwell, S W; Mueller, G P; Yuan, P; Drevets, W C; Manji, H K; Vythlingam, M; Charney, D S; Neumeister, A; Ursano, R J; Jacobowitz, D M; Pollard, H B; Bonne, O
2017-01-01
Post-traumatic stress disorder (PTSD) is psychiatric disease, which can occur following exposure to traumatic events. PTSD may be acute or chronic, and can have a waxing and waning course of symptoms. It has been hypothesized that proinflammatory cytokines and chemokines in the cerebrospinal fluid (CSF) or plasma might be mediators of the psychophysiological mechanisms relating a history of trauma exposure to changes in behavior and mental health disorders, and medical morbidity. Here we test the cytokine/chemokine hypothesis for PTSD by examining levels of 17 classical cytokines and chemokines in CSF, sampled at 0900 hours, and in plasma sampled hourly for 24 h. The PTSD and healthy control patients are from the NIMH Chronic PTSD and healthy control cohort, initially described by Bonne et al. (2011), in which the PTSD patients have relatively low comorbidity for major depressive disorder (MDD), drug or alcohol use. We find that in plasma, but not CSF, the bivariate MCP4 (CCL13)/ MCP1(CCL2) ratio is ca. twofold elevated in PTSD patients compared with healthy controls. The MCP-4/MCP-1 ratio is invariant over circadian time, and is independent of gender, body mass index or the age at which the trauma was suffered. By contrast, MIP-1β is a candidate biomarker for PTSD only in females, whereas TARC is a candidate biomarker for PTSD only in males. It remains to be discovered whether these disease-specific differences in circadian expression for these specific immune signaling molecules are biomarkers, surrogates, or drivers for PTSD, or whether any of these analytes could contribute to therapy. PMID:28170001
Research methods of plasma stream interaction with heat-resistant materials
NASA Astrophysics Data System (ADS)
Tyuftyaev, A. S.; Gadzhiev, M. Kh; Sargsyan, M. A.; Chinnov, V. F.; Demirov, N. A.; Kavyrshin, D. I.; Ageev, A. G.; Khromov, M. A.
2016-11-01
An experimental automated system was designed and constructed for studying the parameters and characteristics of non-stationary interacting system high-enthalpy-plasma stream-investigated sample: enthalpy of plasma in the incident stream; speed and temperature of plasma stream; temperature of electrons and heavy particles, ionic composition and their spatial distribution; heat flux incident on the sample (kW/cm2); surface temperature of the sample; ablation of the sample material, and others. Measurements of achievable plasma heat flux levels are carried out by calorimetry of plasma streams incident on the surface of multisection copper calorimeter. Determination of acceleration characteristics for profiled plasma torch nozzle, as well as the gas flow rate is produced by measuring the total pressure using the Pitot tube. Video visualization of interacting system is carried out using synchronized high-speed cameras. Micropyrometry of the selected zone on the sample surface is carried out by high-speed, three-wavelength pyrometer. To measure the rate of mass loss of the sample, in addition to the weighing method of evaluation the methods of laser knife and two-position stereoscopy are used. Plasma and sample emission characteristics are performed with two separate spectrometers.
Plasma endotoxin activity in Eastern grey kangaroos (Macropus giganteus) with lumpy jaw disease.
Sotohira, Yukari; Suzuki, Kazuyuki; Otsuka, Marina; Tsuchiya, Masakazu; Shimamori, Toshio; Nishi, Yasunobu; Tsukano, Kenji; Asakawa, Mitsuhiko
2017-06-29
Progressive pyogranulomatous osteomyelitis involving the mandible or maxilla of captive macropods, referred to as "Lumpy jaw disease (LJD)", is one of the most significant causes of illness and death in captive macropods. The aim of the present study was to evaluate the relationship between the severity of LJD and plasma endotoxin activity in kangaroos. Plasma samples obtained from moderate (n=24) and severe LJD (n=12), and healthy kangaroos (n=46), were diluted 1:20 in endotoxin-free water and heated to 80°C for 10 min. Plasma endotoxin activity was measured using the Limulus amebocyte lysate (LAL)-kinetic turbidimetric (KT) assay. Plasma endotoxin activity was higher in kangaroos with severe LJD (0.199 ± 0.157 EU/ml) than in those with moderate LJD (0.051 ± 0.012 EU/ml, P<0.001) and healthy controls (0.057 ± 0.028 EU/ml, P<0.001). Our results suggest that the severity of LJD in captive macropods may be related to the plasma endotoxin activity.
Ito, Yoshinori; Suzuki, Michio; Kawada, Jun-ichi; Kimura, Hiroshi
2016-04-01
Chronic active Epstein-Barr virus disease (CAEBV) is a distinct EBV-associated lymphoproliferative disease with a poor prognosis. Although the viral load in blood samples has been widely used for diagnosing CAEBV, well-defined viral load thresholds to guide clinicians are currently lacking. The aim of the present study was to determine standardized diagnostic values for EBV load in blood samples of CAEBV patients using the World Health Organization international standard for reporting. Levels of EBV DNA in 103 peripheral blood mononuclear cells (PBMCs) and 95 plasma/serum samples from 107 cases with CAEBV were quantified and expressed in international units. Receiver operating characteristic curves were analyzed to assess the most appropriate cut-off values for levels of EBV DNA to distinguish CAEBV from EBV-associated infectious mononucleosis (IM) and controls with past EBV infection. Levels of EBV DNA in PBMCs were significantly higher in the CAEBV group (median, 10(4.2) IU/μgDNA) compared to the IM (median, 10(2.1) IU/μgDNA) and control groups. An inconsistent qualitative result was seen in 13 of 86 CAEBV patients; in these, EBV-DNA was positive in PBMCs, but negative in plasma. Diagnostic cut-off values for viral load in PBMCs from CAEBV patients, as compared to those of healthy controls and IM patients, were 10(2.0) IU/μgDNA and 10(3.2) IU/μgDNA, respectively. For diagnostic purposes, the viral load of PBMCs was better than of plasma/serum. A diagnostic cut-off EBV load for CAEBV may be useful for the management of CAEBV patients. Copyright © 2015 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Augmentation of thrombin generation in neonates undergoing cardiopulmonary bypass.
Guzzetta, N A; Szlam, F; Kiser, A S; Fernandez, J D; Szlam, A D; Leong, T; Tanaka, K A
2014-02-01
Factor concentrates are currently available and becoming increasingly used off-label for treatment of bleeding. We compared recombinant activated factor VII (rFVIIa) with three-factor prothrombin complex concentrate (3F-PCC) for the ability to augment thrombin generation (TG) in neonatal plasma after cardiopulmonary bypass (CPB). First, we used a computer-simulated coagulation model to assess the impact of rFVIIa and 3F-PCC, and then performed similar measurements ex vivo using plasma from neonates undergoing CPB. Simulated TG was computed according to the coagulation factor levels from umbilical cord plasma and the therapeutic levels of rFVIIa, 3F-PCC, or both. Subsequently, 11 neonates undergoing cardiac surgery were enrolled. Two blood samples were obtained from each neonate: pre-CPB and post-CPB after platelet and cryoprecipitate transfusion. The post-CPB products sample was divided into control (no treatment), control plus rFVIIa (60 nM), and control plus 3F-PCC (0.3 IU ml(-1)) aliquots. Three parameters of TG were measured ex vivo. The computer-simulated post-CPB model demonstrated that rFVIIa failed to substantially improve lag time, TG rate and peak thrombin without supplementing prothrombin. Ex vivo data showed that addition of rFVIIa post-CPB significantly shortened lag time; however, rate and peak were not statistically significantly improved. Conversely, 3F-PCC improved all TG parameters in parallel with increased prothrombin levels in both simulated and ex vivo post-CPB samples. Our data highlight the importance of prothrombin replacement in restoring TG. Despite a low content of FVII, 3F-PCC exerts potent procoagulant activity compared with rFVIIa ex vivo. Further clinical evaluation regarding the efficacy and safety of 3F-PCC is warranted.
Serum samples can be substituted by plasma samples for the diagnosis of paratuberculosis.
Goodridge, Amador; Correa, Ricardo; Castro, Paul; Escobar, Cecilia; de Waard, Jacobus H
2013-10-01
Employing plasma samples rather than serum samples for serological paratuberculosis diagnosis is practical, especially when bovine TB is assessed in the same cattle herd with the gamma interferon bovine avian (IFN-γ BA) test. We demonstrate that antibody titers in serum and plasma samples, utilizing the PARACHECK(®) ELISA kit, are highly comparable (Cohen's kappa test, k=0.955). We conclude that serum can be replaced with plasma in this commercially available antibody detection assay resulting in working hour savings for sampling and blood sample work-up and cost reductions for materials and sample storage. Copyright © 2013 Elsevier B.V. All rights reserved.
LC-MS/MS quantification of 7α-hydroxy-4-cholesten-3-one (C4) in rat and monkey plasma.
Kang, Lijuan; Connolly, Thomas M; Weng, Naidong; Jian, Wenying
2017-10-01
7α-hydroxy-4-cholesten-3-one (C4) is an oxidative enzymatic product of cholesterol metabolism via cholesterol 7α-hydroxylase, an enzyme also known as cholesterol 7-alpha-monooxygenase or cytochrome P450 7A1 (CYP7A1). C4 is a stable intermediate in the rate limiting pathway of bile acid biosynthesis. Previous studies showed that plasma C4 levels correlated with CYP7A1 enzymatic activity and could serve as a biomarker for bile acid synthesis. Here we developed and qualified a simple and robust high-throughput method using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) to quantify C4 in rat and monkey plasma. As C4 being an endogenous compound, this method used calibration standards in 50/50: acetonitrile/water (v/v). In order to mimic the incurred samples, quality control samples were prepared in the authentic plasma. Stable isotope labeled C4 (C4-d 7 ) was used as the internal standard. The sample volume for analysis was 20μL and the sample preparation method was protein precipitation with acetonitrile. The average endogenous C4 concentrations, from 10 different lots of rat and monkey plasma, were 53.0±16.5ng/mL and 6.8±5.6ng/mL, respectively. Based on these observed endogenous C4 levels, the calibration curve ranges were established at 1-200ng/mL and 0.5-100ng/mL for rat assay and monkey assay, respectively. The method was qualified with acceptable accuracy, precision, linearity, and specificity. Matrix effect, recovery, and plasma stability of bench-top, freeze-thaw, and long-term frozen storage were also evaluated. The method has been successfully applied to pre-clinical studies. Copyright © 2017 Elsevier B.V. All rights reserved.
Raltegravir Cerebrospinal Fluid Concentrations in HIV-1 Infection
Yilmaz, Aylin; Gisslén, Magnus; Spudich, Serena; Lee, Evelyn; Jayewardene, Anura; Aweeka, Francesca; Price, Richard W.
2009-01-01
Introduction Raltegravir is an HIV-1 integrase inhibitor currently used in treatment-experienced HIV-1-infected patients resistant to other drug classes. In order to assess its central nervous system penetration, we measured raltegravir concentrations in cerebrospinal fluid (CSF) and plasma in subjects receiving antiretroviral treatment regimens containing this drug. Methods Raltegravir concentrations were determined by liquid chromatography tandem mass spectrometry in 25 paired CSF and plasma samples from 16 HIV-1-infected individuals. The lower limit of quantitation was 2.0 ng/ml for CSF and 10 ng/ml for plasma. Results Twenty-four of the 25 CSF samples had detectable raltegravir concentrations with a median raltegravir concentration of 18.4 ng/ml (range, <2.0–126.0). The median plasma raltegravir concentration was 448 ng/ml (range, 37–5180). CSF raltegravir concentrations correlated with CSF:plasma albumin ratios and CSF albumin concentrations. Conclusions Approximately 50% of the CSF specimens exceeded the IC95 levels reported to inhibit HIV-1 strains without resistance to integrase inhibitors. In addition to contributing to control of systemic HIV-1 infection, raltegravir achieves local inhibitory concentrations in CSF in most, but not all, patients. Blood-brain and blood-CSF barriers likely restrict drug entry, while enhanced permeability of these barriers enhances drug entry. PMID:19721718
NASA Astrophysics Data System (ADS)
Bedoya, Felipe; Allain, Jean Paul; Kaita, Robert; Lucia, Matthew; St-Onge, Denis; Ellis, Robert; Majeski, Richard
2014-10-01
The Materials Analysis Particle Probe (MAPP) is an in-situ diagnostic designed to characterize plasma-facing components (PFCs) in tokamak devices. MAPP is installed in LTX at Princeton Plasma Physics Laboratory. MAPP's capabilities include remotely operated XPS acquisition and temperature control of four samples. The recent addition of a focused ion beam allows XPS depth profiling analysis. Recent published results show an apparent correlation between hydrogen retention and temperature of Li coated stainless steel (SS) PFCs exposed to plasmas like those of LTX. According to XPS data, the retention of hydrogen by the coated surfaces decreases at above 180 °C. In the present study MAPP will be used to study the oxidation of Li coatings as a function of time and temperature of the walls when Li coatings are applied. Experiments in the ion-surface interaction experiment (IIAX) varying the hydrogen fluence on the SS samples will be also performed. Conclusions resulting from this study will be key to explain the PFC temperature-dependent variation of plasma performance observed in LTX. This work was supported by U.S. DOE Contracts DE-AC02-09CH11466, DE-AC52-07NA27344 and DE-SC0010717.
Stripline split-ring resonator with integrated optogalvanic sample cell
NASA Astrophysics Data System (ADS)
Persson, Anders; Berglund, Martin; Thornell, Greger; Possnert, Göran; Salehpour, Mehran
2014-04-01
Intracavity optogalvanic spectroscopy (ICOGS) has been proposed as a method for unambiguous detection of rare isotopes. Of particular interest is 14C, where detection of extremely low concentrations in the 1:1015 range (14C: 12C), is of interest in, e.g., radiocarbon dating and pharmaceutical sciences. However, recent reports show that ICOGS suffers from substantial problems with reproducibility. To qualify ICOGS as an analytical method, more stable and reliable plasma generation and signal detection are needed. In our proposed setup, critical parameters have been improved. We have utilized a stripline split-ring resonator microwave-induced microplasma source to excite and sustain the plasma. Such a microplasma source offers several advantages over conventional ICOGS plasma sources. For example, the stripline split-ring resonator concept employs separated plasma generation and signal detection, which enables sensitive detection at stable plasma conditions. The concept also permits in situ observation of the discharge conditions, which was found to improve reproducibility. Unique to the stripline split-ring resonator microplasma source in this study, is that the optogalvanic sample cell has been embedded in the device itself. This integration enables improved temperature control and more stable and accurate signal detection. Significant improvements are demonstrated, including reproducibility, signal-to-noise ratio, and precision.
Heishima, Yasuhiro; Hori, Yasutomo; Chikazawa, Seishiro; Kanai, Kazutaka; Hoshi, Fumio; Itoh, Naoyuki
2016-08-01
OBJECTIVE To investigate the in vitro stability of atrial natriuretic peptide (ANP) in plasma samples under various storage conditions and the influence of anesthesia on plasma ANP concentration in cats. ANIMALS 1 cat with congestive heart failure and 5 healthy adult mixed-breed cats. PROCEDURES A plasma sample from the cat with heart failure was serially diluted, and dilutional parallelism of ANP concentration was evaluated. Plasma samples containing aprotinin or serum samples from the 5 healthy cats were kept at room temperature (27°C) for ≤ 12 hours. Plasma samples from the same healthy cats were stored at -70°, -20°, or 4°C for ≤ 14 days. Plasma samples were obtained from the healthy cats before and during isoflurane anesthesia. Plasma ANP concentrations were measured at a commercial laboratory by use of a human ANP chemiluminescence assay. RESULTS Intra- and interassay coefficients of variation were 1.5% and 2.5%, respectively, and dilutional parallelism was established. Although ANP concentration decreased by 82.4 ± 13.6% (mean ± SD) after sample storage for 12 hours at room temperature, this decrease was prevented by aprotinin. Plasma ANP concentrations were stable for 7 days at -20°C and for 14 days at -70°C. However, concentrations decreased markedly to 57.6 ± 6.9% at -20°C and to 18.0 ± 3.0% at 4°C after 14 days. Plasma ANP concentration decreased significantly in cats during anesthesia and was correlated with blood pressure. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that aprotinin should be added routinely in preparation of plasma samples from cats for measurement of ANP concentration, and those samples, if stored, should be frozen immediately at ≤ -20°C. General anesthesia or systemic blood pressure may affect plasma ANP concentration in cats.
Skulas-Ray, Ann C.; Kris-Etherton, Penny M.; Teeter, Danette L.; Chen, C-Y. Oliver; Vanden Heuvel, John P.; West, Sheila G.
2011-01-01
There is much interest in the potential of dietary antioxidants to attenuate in vivo oxidative stress, but little characterization of the time course of plasma effects exists. Culinary spices have demonstrated potent in vitro antioxidant properties. The objective of this study was to examine whether adding 14 g of a high antioxidant spice blend to a 5060-kJ (1200 kcal) meal exerted significant postprandial effects on markers of plasma antioxidant status and metabolism. Healthy overweight men (n = 6) consumed a control and spiced meal in a randomized crossover design with 1 wk between testing sessions. Blood was sampled prior to the meal and at 30-min intervals for 3.5 h (total of 8 samples). Mixed linear models demonstrated a treatment × time interaction (P < 0.05) for insulin and TG, corresponding with 21 and 31% reductions in postprandial levels with the spiced meal, respectively. Adding spices to the meal significantly increased the ferric reducing antioxidant power, such that postprandial increases following the spiced meal were 2-fold greater than after the control meal (P = 0.009). The hydrophilic oxygen radical absorbance capacity (ORAC) of plasma also was increased by spices (P = 0.02). There were no treatment differences in glucose, total thiols, lipophilic ORAC, or total ORAC. The incorporation of spices into the diet may help normalize postprandial insulin and TG and enhance antioxidant defenses. PMID:21697300
Kwok, Wai Him; Choi, Timmy L S; So, Pui-Kin; Yao, Zhong-Ping; Wan, Terence S M
2017-02-01
Xenon can activate the hypoxia-inducible factors (HIFs). As such, it has been allegedly used in human sports for increasing erythropoiesis. Krypton, another noble gas with reported narcosis effect, can also be expected to be a potential and less expensive erythropoiesis stimulating agent. This has raised concern about the misuse of noble gases as doping agents in equine sports. The aim of the present study is to establish a method for the simultaneous detection of xenon and krypton in equine plasma for the purpose of doping control. Xenon- or krypton-fortified equine plasma samples were prepared according to reported protocols. The target noble gases were simultaneously detected by gas chromatography-triple quadrupole mass spectrometry using headspace injection. Three xenon isotopes at m/z 129, 131, and 132, and four krypton isotopes at m/z 82, 83, 84, and 86 were targeted in selected reaction monitoring mode (with the precursor ions and product ions at identical mass settings), allowing unambiguous identification of the target analytes. Limits of detection for xenon and krypton were about 19 pmol/mL and 98 pmol/mL, respectively. Precision for both analytes was less than 15%. The method has good specificity as background analyte signals were not observed in negative equine plasma samples (n = 73). Loss of analytes under different storage temperatures has also been evaluated. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
[Automatic adjustment control system for DC glow discharge plasma source].
Wan, Zhen-zhen; Wang, Yong-qing; Li, Xiao-jia; Wang, Hai-zhou; Shi, Ning
2011-03-01
There are three important parameters in the DC glow discharge process, the discharge current, discharge voltage and argon pressure in discharge source. These parameters influence each other during glow discharge process. This paper presents an automatic control system for DC glow discharge plasma source. This system collects and controls discharge voltage automatically by adjusting discharge source pressure while the discharge current is constant in the glow discharge process. The design concept, circuit principle and control program of this automatic control system are described. The accuracy is improved by this automatic control system with the method of reducing the complex operations and manual control errors. This system enhances the control accuracy of glow discharge voltage, and reduces the time to reach discharge voltage stability. The glow discharge voltage stability test results with automatic control system are provided as well, the accuracy with automatic control system is better than 1% FS which is improved from 4% FS by manual control. Time to reach discharge voltage stability has been shortened to within 30 s by automatic control from more than 90 s by manual control. Standard samples like middle-low alloy steel and tin bronze have been tested by this automatic control system. The concentration analysis precision has been significantly improved. The RSDs of all the test result are better than 3.5%. In middle-low alloy steel standard sample, the RSD range of concentration test result of Ti, Co and Mn elements is reduced from 3.0%-4.3% by manual control to 1.7%-2.4% by automatic control, and that for S and Mo is also reduced from 5.2%-5.9% to 3.3%-3.5%. In tin bronze standard sample, the RSD range of Sn, Zn and Al elements is reduced from 2.6%-4.4% to 1.0%-2.4%, and that for Si, Ni and Fe is reduced from 6.6%-13.9% to 2.6%-3.5%. The test data is also shown in this paper.
Lipid profile in oral submucous fibrosis.
Mehrotra, Ravi; Pandya, Shruti; Chaudhary, Ajay Kumar; Singh, Himanshu Pratap; Jaiswal, Ritesh Kumar; Singh, Mangal; Gupta, S C; Singh, Mamta
2009-07-24
Changes in lipid profile have long been associated with malignancies as lipids play a key role in maintenance of cell integrity. This study evaluated the alterations in extended lipid profile in untreated patients of oral submucous fibrosis (OSMF) and studied the correlation between lipid levels with tobacco consumption. In this hospital-based study, 65 clinically diagnosed and histopathologically proven patients of OSMF and 42 age and sex matched controls were studied. In these samples serum lipids including: (i) Total cholesterol, (ii) LDL cholesterol (LDLC), (iii) HDL cholesterol (HDLC) (iv) VLDL cholesterol (VLDLC) (v) triglycerides (vi) Apo-A1 (viii) Apo-B and (viii) LPa were analyzed. A significant decrease in plasma total cholesterol, HDLC and Apo-A1 was observed in patients with OSMF as compared to the controls. Thus an inverse relationship between plasma lipid levels and patients was found in OSMF. The lower levels of plasma cholesterol and other lipid constituents in patients might be due to their increased utilization. The findings strongly warrant an in-depth study of alterations in plasma lipid profile in patients with oral precancerous conditions.
1987-08-01
out. To use each animal as its own control , arterial blood was sampled by means of chronically implanted aortic cannulas 112,13,14]. This simple...APPENDIX B STATISTICAL METHODOLOGY 37 APPENDIX B STATISTICAL METHODOLOGY The balanced design of this experiment (requiring that 25 animals from each...protoccl in that, in numerous cases, samples were collected at odd intervals (invalidating the orthogonality of the design ) and the number of samples’taken
2012-01-01
Background Multiplex cytometric bead assay (CBA) have a number of advantages over ELISA for antibody testing, but little information is available on standardization and validation of antibody CBA to multiple Plasmodium falciparum antigens. The present study was set to determine optimal parameters for multiplex testing of antibodies to P. falciparum antigens, and to compare results of multiplex CBA to ELISA. Methods Antibodies to ten recombinant P. falciparum antigens were measured by CBA and ELISA in samples from 30 individuals from a malaria endemic area of Kenya and compared to known positive and negative control plasma samples. Optimal antigen amounts, monoplex vs multiplex testing, plasma dilution, optimal buffer, number of beads required were assessed for CBA testing, and results from CBA vs. ELISA testing were compared. Results Optimal amounts for CBA antibody testing differed according to antigen. Results for monoplex CBA testing correlated strongly with multiplex testing for all antigens (r = 0.88-0.99, P values from <0.0001 - 0.004), and antibodies to variants of the same antigen were accurately distinguished within a multiplex reaction. Plasma dilutions of 1:100 or 1:200 were optimal for all antigens for CBA testing. Plasma diluted in a buffer containing 0.05% sodium azide, 0.5% polyvinylalcohol, and 0.8% polyvinylpyrrolidone had the lowest background activity. CBA median fluorescence intensity (MFI) values with 1,000 antigen-conjugated beads/well did not differ significantly from MFI with 5,000 beads/well. CBA and ELISA results correlated well for all antigens except apical membrane antigen-1 (AMA-1). CBA testing produced a greater range of values in samples from malaria endemic areas and less background reactivity for blank samples than ELISA. Conclusion With optimization, CBA may be the preferred method of testing for antibodies to P. falciparum antigens, as CBA can test for antibodies to multiple recombinant antigens from a single plasma sample and produces a greater range of values in positive samples and lower background readings for blank samples than ELISA. PMID:23259607
Botta, Céline; Iarmarcovai, Gwenaëlle; Chaspoul, Florence; Sari-Minodier, Irène; Pompili, Jocelyne; Orsière, Thierry; Bergé-Lefranc, Jean-Louis; Botta, Alain; Gallice, Philippe; De Méo, Michel
2006-05-01
Welding fumes are classified as possibly carcinogenic to humans (Group 2B) by the International Agency for Research on Cancer. In the current study, blood and urine concentrations of aluminum (Al), cadmium (Cd), cobalt (Co), chromium (Cr), manganese (Mn), nickel (Ni), lead (Pb), and zinc (Zn) were monitored by inductively coupled plasma-mass spectrometry (ICP-MS) in 30 welders and in 22 controls. In addition, DNA damage was examined in the lymphocytes of these subjects by the alkaline Comet assay. Two biological samples were taken from the welders at the beginning (BW) and at the end (EW) of a work week. In controls, collection of samples was limited to BW. Blood concentrations of Cd, Co, Cr, Ni, and Pb were higher in the welders than in the control group while higher concentrations of Al, Cd, Co, Cr, Ni, and Pb were detected in welder urines. There was no significant difference in the metal concentrations for the BW and EW welder samples. Increased levels of DNA damage were found in lymphocytes from welders as compared to the controls, and 20/30 welders had higher levels of DNA lesions in the EW than in the BW samples. Age had a significant effect on DNA damage in the control group. Spearman's rank correlation analysis indicated that there were positive correlations between blood concentrations of Al, Co, Ni, and Pb and the levels of DNA damage. A negative correlation was found between DNA damage and Mn in blood, while there was a positive correlation between urinary Mn concentration and DNA damage. These data indicate that occupational exposure to welding fumes increases DNA damage in lymphocytes. Copyright (c) 2006 Wiley-Liss, Inc.
X-ray free-electron laser studies of dense plasmas
NASA Astrophysics Data System (ADS)
Vinko, Sam M.
2015-10-01
> The high peak brightness of X-ray free-electron lasers (FELs), coupled with X-ray optics enabling the focusing of pulses down to sub-micron spot sizes, provides an attractive route to generating high energy-density systems on femtosecond time scales, via the isochoric heating of solid samples. Once created, the fundamental properties of these plasmas can be studied with unprecedented accuracy and control, providing essential experimental data needed to test and benchmark commonly used theoretical models and assumptions in the study of matter in extreme conditions, as well as to develop new predictive capabilities. Current advances in isochoric heating and spectroscopic plasma studies on X-ray FELs are reviewed and future research directions and opportunities discussed.
Cold, Frederik; Winther, Kristian H; Pastor-Barriuso, Roberto; Rayman, Margaret P; Guallar, Eliseo; Nybo, Mads; Griffin, Bruce A; Stranges, Saverio; Cold, Søren
2015-12-14
Although cross-sectional studies have shown a positive association between Se and cholesterol concentrations, a recent randomised controlled trial in 501 elderly UK individuals of relatively low-Se status found that Se supplementation for 6 months lowered total plasma cholesterol. The Danish PRECISE (PREvention of Cancer by Intervention with Selenium) pilot study (ClinicalTrials.gov ID: NCT01819649) was a 5-year randomised, double-blinded, placebo-controlled trial with four groups (allocation ratio 1:1:1:1). Men and women aged 60-74 years (n 491) were randomised to 100 (n 124), 200 (n 122) or 300 (n 119) μg Se-enriched yeast or matching placebo-yeast tablets (n 126) daily for 5 years. A total of 468 participants continued the study for 6 months and 361 participants, equally distributed across treatment groups, continued for 5 years. Plasma samples were analysed for total and HDL-cholesterol and for total Se concentrations at baseline, 6 months and 5 years. The effect of different doses of Se supplementation on plasma lipid and Se concentrations was estimated by using linear mixed models. Plasma Se concentration increased significantly and dose-dependently in the intervention groups after 6 months and 5 years. Total cholesterol decreased significantly both in the intervention groups and in the placebo group after 6 months and 5 years, with small and nonsignificant differences in changes in plasma concentration of total cholesterol, HDL-cholesterol, non-HDL-cholesterol and total:HDL-cholesterol ratio between intervention and placebo groups. The effect of long-term supplementation with Se on plasma cholesterol concentrations or its sub-fractions did not differ significantly from placebo in this elderly population.
Berg, Sofia Mikkelsen; Havelund, Jesper; Hasler-Sheetal, Harald; Kruse, Vibeke; Pedersen, Andreas James Thestrup; Hansen, Aleksander Bill; Nybo, Mads; Beck-Nielsen, Henning; Højlund, Kurt; Færgeman, Nils Joakim
Mutations in the lipoprotein lipase gene causing decreased lipoprotein lipase activity are associated with surrogate markers of insulin resistance and the metabolic syndrome in humans. We investigated the hypothesis that a heterozygous lipoprotein lipase mutation (N291S) induces whole-body insulin resistance and alterations in the plasma metabolome. In 6 carriers of a heterozygous lipoprotein lipase mutation (N291S) and 11 age-matched and weight-matched healthy controls, we examined insulin sensitivity and substrate metabolism by euglycemic-hyperinsulinemic clamps combined with indirect calorimetry. Plasma samples were taken before and after the clamp (4 hours of physiological hyperinsulinemia), and metabolites were measured enzymatically or by gas chromatography-mass spectrometry. Compared with healthy controls, heterozygous carriers of a defective lipoprotein lipase allele had elevated fasting plasma levels triglycerides (P < .006), and markedly impaired insulin-stimulated glucose disposal rates (P < .024) and nonoxidative glucose metabolism (P < .015). Plasma metabolite profiling demonstrated lower circulating levels of pyruvic acid and α-tocopherol in the N291S carriers than in controls both before and after stimulation with insulin (all >1.5-fold change and P < .05). Heterozygous carriers with a defective lipoprotein lipase allele are less insulin sensitive and have increased plasma levels of nonesterified fatty acids and triglycerides. The heterozygous N291S carriers also have a distinct plasma metabolomic signature, which may serve as a diagnostic tool for deficient lipoprotein lipase activity and as a marker of lipid-induced insulin resistance. Copyright © 2017 National Lipid Association. Published by Elsevier Inc. All rights reserved.
Pölönen, S; Tiihonen, M; Hartikainen, S; Nykänen, I
2017-01-01
To evaluate the effect of individually tailored dietary counseling on nutritional status among home care clients aged 75 years or older. Non-randomised controlled study. The study sample consisted of 224 home care clients (≥ 75 years) (intervention group, n = 127; control group, n = 100) who were at protein-energy malnutrition (PEM) or risk of PEM (MNA score <24 and plasma albumin <35 g/L). Individually tailored dietary counseling; the persons were instructed to increase their food intake with energy-dense food items, the number of meals they ate and their consumption of energy-, protein- and nutrient-rich snacks for six months. The Mini Nutritional Assessment (MNA), Body Mass Index (BMI) and plasma albumin were used to determine nutritional status at the baseline and after the six-month intervention. The mean age of the home care clients was 84.3 (SD 5.5) in the intervention group and 84.4 (SD 5.3) in the control group, and 70 percent were women in both groups. After the six-month nutritional intervention, the MNA score increased 2.3 points and plasma albumin 1.6 g/L in the intervention group, against MNA score decreased -0.2 points and plasma albumin -0.1 g/L in the control group. Individually tailored dietary counseling may improve nutritional status among older home care clients.
Delben, Juliana Aparecida; Zago, Chaiene Evelin; Tyhovych, Natalia; Duarte, Simone; Vergani, Carlos Eduardo
2016-01-01
Considering the ability of atmospheric-pressure cold plasma (ACP) to disrupt the biofilm matrix and rupture cell structure, it can be an efficient tool against virulent oral biofilms. However, it is fundamental that ACP does not cause damage to oral tissue. So, this study evaluated (1) the antimicrobial effect of ACP on single- and dual-species biofilms of Candida albicans and Staphylococcus aureus as well as (2) the biological safety of ACP on in vitro reconstituted oral epithelium. Standardized cell suspensions of each microorganism were prepared for biofilm culture on acrylic resin discs at 37°C for 48 hours. The biofilms were submitted to ACP treatment at 10 mm of plasma tip-to-sample distance during 60 seconds. Positive controls were penicillin G and fluconazole for S. aureus and C. albicans, respectively. The biofilms were analyzed through counting of viable colonies, confocal laser scanning microscopy, scanning electron microscopy and fluorescence microscopy for detection of reactive oxygen species. The in vitro reconstituted oral epithelium was submitted to similar ACP treatment and analyzed through histology, cytotoxocity test (LDH release), viability test (MTT assay) and imunnohistochemistry (Ki67 expression). All plasma-treated biofilms presented significant log10 CFU/mL reduction, alteration in microorganism/biofilm morphology, and reduced viability in comparison to negative and positive controls. In addition, fluorescence microscopy revealed presence of reactive oxygen species in all plasma-treated biofilms. Low cytotoxicity and high viability were observed in oral epithelium of negative control and plasma group. Histology showed neither sign of necrosis nor significant alteration in plasma-treated epithelium. Ki67-positive cells revealed maintenance of cell proliferation in plasma-treated epithelium. Atmospheric-pressure cold plasma is a promissing approach to eliminate single- and dual-species biofilms of C. albicans and S. aureus without having toxic effects in oral epithelium.
A simple competitive RT-PCR assay for quantitation of HIV-1 subtype B and non-B RNA in plasma.
Hamatake, Makiko; Nishizawa, Masako; Yamamoto, Naoki; Kato, Shingo; Sugiura, Wataru
2007-06-01
An easy, inexpensive competitive RT-PCR assay for HIV-1 RNA quantitation was constructed. A 138-bp sequence in the HIV-1 gag p24 region was selected as the target and co-amplified with competitor RNA containing an internal 44-bp deletion. Quantitation of serial dilutions of control RNA samples prepared from the LAI isolate demonstrated a good linearity (R(2)=0.991) within the range between 10 and 250 copies/sample. The detection limit of the assay was determined to be 3.8 copies/sample by Probit analysis and corresponded to 110 copies/ml in plasma. The intra-assay CV value was 9.1%, and the inter-assay value was 25.9%. Both were comparable to those obtained with commercially available HIV-1 RNA quantitation kits. The correlation efficient for the results obtained in 47 plasma samples from HIV-1-infected individuals (subtype A in 1, subtype B in 25, subtype C in 4, subtype F in 1, and CRF01 AE in 16) with the competitive RT-PCR and Cobas Amplicor HIV-1 Monitor test v1.5 was 0.956 for subtype B and 0.947 for subtype non-B. The assay devised is a good alternative for monitoring antiretroviral therapy in resource-poor countries.
Wu, Jiong; Zhou, Yan; Zhang, Chun-Yan; Song, Bin-Bin; Wang, Bei-Li; Pan, Bai-Shen; Lou, Wen-Hui; Guo, Wei
2014-01-01
The aim of our study was to establish COLD-PCR combined with an unlabeled-probe HRM approach for detecting KRAS codon 12 and 13 mutations in plasma-circulating DNA of pancreatic adenocarcinoma (PA) cases as a novel and effective diagnostic technique. We tested the sensitivity and specificity of this approach with dilutions of known mutated cell lines. We screened 36 plasma-circulating DNA samples, 24 from the disease control group and 25 of a healthy group, to be subsequently sequenced to confirm mutations. Simultaneously, we tested the specimens using conventional PCR followed by HRM and then used target-DNA cloning and sequencing for verification. The ROC and respective AUC were calculated for KRAS mutations and/or serum CA 19-9. It was found that the sensitivity of Sanger reached 0.5% with COLD- PCR, whereas that obtained after conventional PCR did 20%; that of COLD-PCR based on unlabeled-probe HRM, 0.1%. KRAS mutations were identified in 26 of 36 PA cases (72.2%), while none were detected in the disease control and/or healthy group. KRAS mutations were identified both in 26 PA tissues and plasma samples. The AUC of COLD-PCR based unlabeled probe HRM turned out to be 0.861, which when combined with CA 19-9 increased to 0.934. It was concluded that COLD-PCR with unlabeled-probe HRM can be a sensitive and accurate screening technique to detect KRAS codon 12 and 13 mutations in plasma-circulating DNA for diagnosing and treating PA.
NASA Technical Reports Server (NTRS)
Baer, Lisa A.; Wade, Charles E.; Plaut, Karen; Ronca, April E.; Dalton, Bonnie (Technical Monitor)
2002-01-01
From pregnancy to weaning there is a progressive elevation of plasma oxytocin (OT) levels associated with nursing activity, irrespective of litter size. In the present study, we analyzed the effects of continuous 1.5G, 1.75G and 2.0G hypergravity exposure on OT plasma concentration in prepartum (Gestation Day 20) (G20) and lactating (Postnatal day) (P10) rat dams. For this study, litter size was controlled with a yoking procedure established in our lab where individual control litters were yoked-matched to individual hypergravity litters. We reviewed all data at hypergravity irrespective of gravitational level and compared the values with the controls in both G20 (HG, n=15;SC, n=9) and P10 (HG, n=21;SC, n=16). Results showed that over time, we did observe the expected OT increase in both groups. In G20 dams, measurement of OT concentrations showed no significance. However, at P10, measurements of OT concentrations suggest a reduction of about 20% compared to established controls in our laboratory, 0.9+/-0.09 ng/ml for the controls and 0.7+/-0.06 ng/ml for centrifuged animals (p<0.02). These data suggest that exposure to centrifugation may reduce OT levels during lactation. When these plasma samples were obtained, the dams were removed from the litters, and values were not adjusted for the size of the litters. The reduction in OT with centrifugation may reflect a decrease in nursing activity or a decreased responsiveness of the mammary hypothalamic axis. In addition, we have analyzed data on plasma prolactin concentrations and mammary gland development, which may give additional insight to the results of our OT measurements.
Erythrocyte deformability and oxidative stress in inflammatory bowel disease.
Akman, Tulay; Akarsu, Mesut; Akpinar, Hale; Resmi, Halil; Taylan, Ebru; Sezer, Ebru
2012-02-01
Oxidative stress and reduced microvascular flow are important factors in the pathogenesis of inflammatory bowel disease (IBD). The increased oxidative stress reduces the erythrocyte deformability. However, in IBD, there are no studies in the literature which evaluate erythrocyte deformability. In our study, we investigated the effect of oxidative stress and erythrocyte deformability in IBD. Forty-three patients with active IBD, 48 patients with inactive IBD and 45 healthy controls were included. The erytrocyte deformability, malonyldialdehyde levels, glutation peroxidase and sulfhydryl levels were measured in peripheral venous blood samples. Erytrocyte malonyldialdehyde levels in both active and inactive IBD were significantly increased compared with control groups. Plasma glutation peroxidase levels did not show statistically significant difference between all groups. The decreased plasma sulfhydryl levels in active IBD were statistically significant compared with both the inactive IBD and the control group, but plasma sulfhydryl levels in inactive IBD group did not show statistically significant differences when compared with the control group. Elongation index values in both active and inactive IBD increased significantly compared with the control group. Statistically significant correlations were not found between the elongation index and glutation peroxidase, malonyldialdehyde, sulfhydryl levels in all groups. Our study is the first to evaluate the erythrocyte deformability in IBD. In our study, increased erytrocyte malonyldialdehyde levels and decreased plasma sulfhydryl levels manifested the role of oxidative stress in the pathogenesis of the disease. It is thought that the increased erythrocyte malonyldialdehyde values cause the reduction in erythrocyte deformability.
Alkmin, Diego V; Perez-Patiño, Cristina; Barranco, Isabel; Parrilla, Inmaculada; Vazquez, Juan M; Martinez, Emilio A; Rodriguez-Martinez, Heriberto; Roca, Jordi
2014-10-01
Boar bulk ejaculates are now being collected instead of usual sperm-rich fractions (SRF) for artificial insemination purpose. The present study evaluated the influence of holding boar sperm samples before freezing surrounded in their own seminal plasma (SP), from either fractions/portions or the entire ejaculate, on post-thawing sperm quality and functionality. Ejaculates collected as bulk (BE) or as separate (first 10 mL of SRF [P1] and rest of SRF [P2]) from 10 boars were held 24h at 15-17°C and then frozen. Some bulk ejaculate samples were frozen immediately after collections as Control. In addition, epididymal sperm samples from the same 10 boars were collected post-mortem and extended in SP from P1 (EP1), P2 (EP2) and post SRF (EP3), and also held 24h before freezing for a better understanding of the influence of SP on boar sperm cryopreservation. The sperm quality (motility, evaluated by CASA, and viability, evaluated by flow cytometry) and functionality (flow cytometry assessment of plasma membrane fluidity, mitochondrial membrane potential and intracellular generation of reactive oxygen species [ROS] in viable sperm) were evaluated at 30, 150 and 300 min post-thaw. Post-thawing sperm quality and functionality of P1 and P2 were similar but higher (p < 0.01) than BE samples. Control samples showed higher (p < 0.01) post-thaw sperm quality and functionality than BE samples. Post-thawing sperm quality and functionality of EP1 and EP2 were similar but higher (p < 0.05) than EP3. These results showed that boar sperm from BE are more cryosensitive than those from the SRF, particularly when held 24h before freezing, which would be attributable to the cryonegative effects exerted by the SP from post SRF. Copyright © 2014 Elsevier Inc. All rights reserved.
Modeling of high-Z materials erosion and its suppression in DIII-D
NASA Astrophysics Data System (ADS)
Ding, Rui; Guo, H. Y.; Chan, V. S.; Snyder, P. B.; Rudakov, D. L.; Stangeby, P. C.; Elder, J. D.; Tskhakaya, D.; Wampler, W. R.; Kirschner, A.; McLean, A. G.
2015-11-01
Erosion of plasma facing components is a key issue for high-power, long pulse operation. The 3D Monte Carlo code ERO has been used to simulate the erosion/redeposition of Mo and W samples exposed to DIII-D divertor plasma using the DiMES. The net erosion rate is significantly reduced due to the high local re-deposition ratio of eroded materials, which is mainly controlled by the electric field and plasma density within the Chodura sheath as indicated by ERO modeling. Similar re-deposition ratios were obtained from the modeling using three sheath models for small inclined magnetic field angle, all being close to the measured value. ERO modeling shows that local CH4 injection can create a carbon coating on the Mo sample to mitigate Mo erosion; the local decrease of electron temperature due to gas injection also suppresses net erosion, consistent with experimental observation. Supported by the US DOE under DE-FC02-04ER54698 and PSI-SciDAC project.
Fast Plasma Investigation for Magnetospheric Multiscale
NASA Technical Reports Server (NTRS)
Pollock, C.; Moore, T.; Coffey, V.; Dorelli J.; Giles, B.; Adrian, M.; Chandler, M.; Duncan, C.; Figueroa-Vinas, A.; Garcia, K.;
2016-01-01
The Fast Plasma Investigation (FPI) was developed for flight on the Magnetospheric Multiscale (MMS) mission to measure the differential directional flux of magnetospheric electrons and ions with unprecedented time resolution to resolve kinetic-scale plasma dynamics. This increased resolution has been accomplished by placing four dual 180-degree top hat spectrometers for electrons and four dual 180-degree top hat spectrometers for ions around the periphery of each of four MMS spacecraft. Using electrostatic field-of-view deflection, the eight spectrometers for each species together provide 4pi-sr-field-of-view with, at worst, 11.25-degree sample spacing. Energy/charge sampling is provided by swept electrostatic energy/charge selection over the range from 10 eVq to 30000 eVq. The eight dual spectrometers on each spacecraft are controlled and interrogated by a single block redundant Instrument Data Processing Unit, which in turn interfaces to the observatory's Instrument Suite Central Instrument Data processor. This paper described the design of FPI, its ground and in-flight calibration, its operational concept, and its data products.
El-Ansary, Afaf K; Bacha, Abir Ben; Ayahdi, Layla Y Al-
2011-09-01
This study aims to clarify the relationship between blood Pb(2+) concentration as a ubiquitous environmental pollutant and plasma neurotransmitters as biochemical parameters that reflect brain function in Saudi autistic patients. RBC's lead content together with plasma concentration of gamma aminobutyric acid (GABA), serotonin (5HT) and dopamine (DA) were measured in 25 Saudi autistic patients and compared to 16 age-matching control samples. The obtained data recorded that Saudi autistic patients have a remarkable higher levels of Pb(2+) and significantly elevated levels of GABA, 5HT and DA compared to healthy subjects. ROC analysis revealed satisfactory values of specificity and sensitivity of the measured parameters. This study suggests that postnatal lead toxicity in autistic patients of Saudi Arabia could represent a causative factor in the pathogenesis of autism. Elevated GABA, 5HT and DA were discussed in relation to the chronic lead toxicity recorded in the investigated autistic samples. Copyright © 2011. Published by Elsevier Inc.
Ma, Yu; Xia, Yun; Yang, Xiaolan; Yu, Ming'an
2003-06-01
Virus inactivation of plasma can be achieved by phototreatment with methylene blue (MB). Subsequently, elimination of MB may reduce the adverse effects of MB. This study examined the effects of adsorbing MB with the use of cross-linked agar bead entrapped attapulgite clay (CAA) on normal ingredients in MB-treated plasma units. The biomedical characteristics of CAA were assessed by determination of partial biochemical indexes, coagulation potency and some cationic concentration in a control sample and the MB-treated plasma eluted from CAA column. The biochemistry indexes or K+, Na+ in plasma were almost unaltered before and after CAA adsorption. In contrast, the concentrations of CA2+ and Mg2+ increased and the blood ammonium decreased obviously. The activated partial thromboplastin time (APTT) was prolonged from 42 s to 53 s, and prothrombin time (PT) from 13 s to 14 s. The result indicates that CAA as an adsorbent for hemopurification retains the most important characters of human plasma. CAA can be useful for the elimination of MB in MB-treated plasma and does not bring on harmful alteration in clinical significance.
Plasma volume, osmolality, vasopressin, and renin activity during graded exercise in man
NASA Technical Reports Server (NTRS)
Convertino, V. A.; Keil, L. C.; Bernauer, E. M.; Greenleaf, J. E.
1981-01-01
The influence of work intensity on plasma volume, osmolality, vasopressin and renin activity and the interrelationships between these responses are investigated. Plasma volume, renin activity and osmotic, sodium and arginine vasopressin concentrations were measured in venous blood samples taken from 15 healthy male subjects before and after six minutes of bicycle ergometer exercise at 100, 175 and 225 W. Plasma volume is found to decrease significantly with increasing work intensity, while increases in Na(+) concentration, osmolality and vasopressin are only observed to be significant when the work intensity exceeds 40% maximal aerobic capacity and plasma resin activity increased linearly at all work levels. In addition, significant correlations are observed between plasma volume and osmolality and sodium changes, and between vasopressin and osmolality and sodium content changes. Data thus support the hypotheses that (1) vasopressin may be the primary controlling endocrine for fluid and electrolyte levels following exercise; (2) an exercise intensity greater than 40% maximal aerobic capacity is required to stimulate vasopressin release through changes in plasma osmolality; and (3) the stimulation of the renin-angiotensin system is a more general stress response.
2013-01-01
Background Previous studies carried out in our laboratories have demonstrated impaired drug permeation in diabetic animals. In this study the permeation of diazepam (after a single dose of 5 mg/day, administered intramuscularly) will be investigated in diabetic and hypertensive pregnant women. Methods A total 75 pregnant women were divided into three groups: group 1 (healthy control, n = 31), group 2 (diabetic, n = 14) and group 3 (hypertensive, n = 30). Two sets of diazepam plasma concentrations were collected and measured (after the administration of the same dose of diazepam), before, during and after delivery. The first set of blood samples was taken from the mother (maternal venous plasma). The second set of samples was taken from the fetus (fetal umbilical venous and arterial plasma). In order to assess the effect of diabetes and hypertension on diazepam placental-permeation, the ratios of fetal to maternal blood concentrations were determined. Differences were considered statistically significant if p ≤ 0.05. Results The diabetes and hypertension groups have 2-fold increase in the fetal umbilical-venous concentrations, compared to the maternal venous concentrations. Feto: maternal plasma-concentrations ratios were higher in diabetes (2.01 ± 1.10) and hypertension (2.26 ± 1.23) groups compared with control (1.30 ± 0.48) while, there was no difference in ratios between the diabetes and hypertension groups. Umbilical-cord arterial: venous ratios (within each group) were similar among all groups (control: 0.97 ± 0.32; hypertension: 1.08 ± 0.60 and diabetes: 1.02 ± 0.77). Conclusions On line with our previous findings which demonstrate disturbed transcellular trafficking of lipophilic drugs in diabetes, this study shows significant increase in diazepam placental-permeation in diabetic and hypertensive pregnant women suggesting poor transcellular control of drug permeation and flux, and bigger exposure of the fetus to drug-placental transport. PMID:24134697
The fine structure of Langmuir waves observed upstream of the bow shock at Venus
NASA Technical Reports Server (NTRS)
Hospodarsky, G. B.; Gurnett, D. A.; Kurth, W. S.; Kivelson, M. G.; Strangeway, R. J.; Bolton, S. J.
1994-01-01
Highly structured Langmuir waves, also known as electron plasma oscillations, have been observed in the foreshock of Venus using the plasma wave experiment on the Galileo spacecraft during the gravity assist flyby on February 10, 1990. The Galileo wideband sampling system provides digital electric field waveform measurements at sampling rates up to 201,600 samples per second, much higher than any previous instrument of this type. The main Langmuir wave emission band occurs near the local electron plasma frequency, which was approximately 43 kHz. The Langmuir waves are observed to shift above and below the plasma frequency, sometimes by as much as 20 kHz. The shifts in frequency are closely correlated with the downstream distance from the tangent field line, implying that the shifts are controlled by the electron beam velocity. Considerable fine structure is also evident, with time scales as short as 0.15 milliseconds, corresponding to spatial scales of a few tens of Debye lengths. The frequency spectrum often consists of beat-type waveforms, with beat frequencies ranging from 0.2 to 7 kHz, and in a few cases, isolated wavepackets. The peak electric field strengths are approximately 1 mV/m. These field strengths are too small for strongly nonlinear processes to be important. The beat-type waveforms are suggestive of a parametric decay process.
Haeckel, Rainer; Hänecke, Petra
2003-07-01
The comparability between glucose concentrations measured in various sample systems is still a matter of debate. Decision limits are usually determined in venous plasma and then converted to either blood or to the aqueous compartment (activity). The conversion factors recommended have not yet been generally accepted. In the present study, glucose concentrations were determined in blood and plasma with an Ebio analyser (molarity) and in the aqueous compartment with both an EML 105 and an Omni (molality). All analytical results were referred to the same aqueous standard solution. The Ebio results agreed with reference method values in control materials. Concentrations determined in the various sample systems from patients (molarity) correlated well with the molality values measured either with the EML or the Omni. However, the mean values of the EML were not consistent with those derived theoretically by considering the different water content. With the Omni, only molality values in whole blood appeared plausible, but not in plasma, although the two sample systems should provide identical molality values. The EML results were almost identical in whole blood and plasma. Theoretically, glucose molality would be the ideal diagnostic quantity. However, no diagnostic advantage of molality determined in whole blood with the Omni vs. molarity values could be detected in a group of 40 non-diabetic and 27 diabetic subjects.
Miller, Tricia M; Poloyac, Samuel M; Anderson, Kacey B; Waddell, Brooke L; Messamore, Erik; Yao, Jeffrey K
2017-01-18
A rapid and sensitive method using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed to simultaneously quantify hydroxyeicosatetraenoic (HETE), dihydroxyeicosatrienoic (DiHETrE), epoxyeicosatrienoic acid (EET), and prostaglandin metabolites of arachidonic acid in human plasma. Sample preparation consisted of solid phase extraction with Oasis HLB (30mg) cartridges for all metabolites. Separation of HETEs, EETs, and DiHETrEs was achieved on an Acquity UPLC BEH C18, 1.7µm (100×2.1mm) reversed-phase column (Waters Corp, Millford, MA) with negative electrospray ionization mass spectrometric detection. A second injection of the same extracted sample allowed for separation and assessment of prostaglandin metabolites under optimized UPLC-MS/MS conditions. Additionally, the endogenous levels of these metabolites in five different matrices were determined in order to select the optimal matrix for assay development. Human serum albumin was shown to have the least amount of endogenous metabolites, a recovery efficiency of 79-100% and a matrix effect of 71 - 100%. Linear calibration curves ranging from 0.416 to 66.67ng/ml were validated. Inter-assay and intra-assay variance was less than 15% at most concentrations. This method was successfully applied to quantify metabolite levels in plasma samples of healthy control subjects receiving niacin administration to evaluate the association between niacin administration and eicosanoid plasma level response. Published by Elsevier Ltd.
Gulley, Margaret L; Fan, Hongxin; Elmore, Sandra H
2006-11-01
Epstein-Barr virus (EBV) is associated with a wide range of benign and malignant diseases, including infectious mononucleosis, lymphoma, posttransplant lymphoproliferative disorder, and nasopharyngeal carcinoma. Measurement of EBV viral load in plasma is increasingly used for rapid assessment of disease status. We evaluated the performance characteristics of an EBV polymerase chain reaction assay that uses commercial reagents and instruments from Roche Diagnostics (Indianapolis, IN). DNA was extracted from plasma using a MagNaPure instrument, and viral load was measured by real-time polymerase chain reaction on a LightCycler. Analyte-specific reagents included primers and hybridization probes targeting the EBV LMP2 gene and a spiked control sequence. Accuracy and reproducibility were established using DNA from three cell lines. The assay was sensitive to approximately 750 copies of EBV DNA per milliliter of plasma and was linear across at least four orders of magnitude. The assay detected EBV DNA in three of five samples from nasopharyngeal carcinoma patients, seven of nine infectious mononucleosis samples, and 34/34 samples from immunosuppressed patients with clinically significant EBV-related disease, whereas EBV DNA was undetectable in plasma from 21 individuals without EBV-related disease. In conclusion, this LightCycler EBV assay is rapid, sensitive, and linear for quantifying EBV viral load. The assay appears to be useful for measuring clinically significant EBV levels in immunodeficient patients.
Serum and Plasma Metabolomic Biomarkers for Lung Cancer.
Kumar, Nishith; Shahjaman, Md; Mollah, Md Nurul Haque; Islam, S M Shahinul; Hoque, Md Aminul
2017-01-01
In drug invention and early disease prediction of lung cancer, metabolomic biomarker detection is very important. Mortality rate can be decreased, if cancer is predicted at the earlier stage. Recent diagnostic techniques for lung cancer are not prognosis diagnostic techniques. However, if we know the name of the metabolites, whose intensity levels are considerably changing between cancer subject and control subject, then it will be easy to early diagnosis the disease as well as to discover the drug. Therefore, in this paper we have identified the influential plasma and serum blood sample metabolites for lung cancer and also identified the biomarkers that will be helpful for early disease prediction as well as for drug invention. To identify the influential metabolites, we considered a parametric and a nonparametric test namely student׳s t-test as parametric and Kruskal-Wallis test as non-parametric test. We also categorized the up-regulated and down-regulated metabolites by the heatmap plot and identified the biomarkers by support vector machine (SVM) classifier and pathway analysis. From our analysis, we got 27 influential (p-value<0.05) metabolites from plasma sample and 13 influential (p-value<0.05) metabolites from serum sample. According to the importance plot through SVM classifier, pathway analysis and correlation network analysis, we declared 4 metabolites (taurine, aspertic acid, glutamine and pyruvic acid) as plasma biomarker and 3 metabolites (aspartic acid, taurine and inosine) as serum biomarker.
Goettel, Michael; Niessner, Reinhard; Mueller, Daniel; Scherer, Max; Scherer, Gerhard; Pluym, Nikola
2017-10-06
Untargeted GC-TOF-MS analysis proved to be a suitable analytical platform to determine alterations in the metabolic profile. Several metabolic pathways were found to be altered in a first clinical study comparing smokers against nonsmokers. Subsequently, we conducted a clinical diet-controlled study to investigate alterations in the metabolic profile during the course of 3 months of smoking cessation. Sixty male subjects were included in the study, and plasma, saliva, and urine samples were collected during four 24 h stationary visits: at baseline, while still smoking, after 1 week, after 1 month, and after 3 months of cessation. Additionally, subjects were monitored for their compliance by measurements of CO in exhaled breath and salivary cotinine throughout the study. GC-TOF-MS fingerprinting was applied to plasma, saliva, and urine samples derived from 39 compliant subjects. In total, 52 metabolites were found to be significantly altered including 26 in plasma, 20 in saliva, and 12 in urine, respectively. In agreement with a previous study comparing smokers and nonsmokers, the fatty acid and amino acid metabolism showed significant alterations upon 3 months of smoking cessation. Thus these results may indicate a partial recovery of metabolic pathway perturbations, even after a relatively short period of smoking cessation.
Gauhar, Shahnaz; Ali, Syed Ayub; Naqvi, Syed Baqir; Shoaib, Muhammad Harris
2014-03-01
In the present study, the pharmacokinetic and drug interaction evaluation of two drugs pefloxacin and paracetamol was carried out by a single-dose, two-treatment and two-sequence crossover design. Total fifteen healthy volunteers participated out of which ten completed the study. All were male volunteers, aged 22.36 years (means), with a mean weight of 76.45±12.05 Kg. The washout period between treatments was 5 week. Initially the method utilized for quantitative analysis of the drug was developed which was further validated. The study involved plasma protein precipitation with ethyl acetate and detection was done at 275nm. The retention time for pefloxacin 18±1 min and paracetamol were approximately 6±1 min, respectively. The calibration curve for pefloxacin was linear in the concentration range of 0.125-12.0mg/ml with r(2)=0.9987 in plasma. Standard concentration solution was maintained on the same temperature as that of volunteer's samples to optimize the periods for the determination of drug concentration in the plasma samples. Blood samples were collected from volunteers at different time intervals. The pharmacokinetics and drug interaction studies were anticipated by plotting concentration versus time-profiles. The value of AUC0-∞ in control was 67.355±3.174μg.h/ml, in treatment 61.242±3.868μg.h/ml along with relative bioavailability =91.395±4.864. Under the control and treatment condition the mean maximum plasma concentrations were found to be 4.679±0.248 μg/ml and 4.6595±0.266 μg/ml respectively. The average T(max) for plasma concentrations was 1.819±0.1743hr and 1.605 ±0.1134hr respectively. The biological half-lives in the two phases of studies were found to be 7.953±0.33hr in control and 7.7257±0.355hr in treatment. No significant effect were observed on the bioavailability and pharmacokinetics of pefloxacin by the concomitant administration with paracetamol, however very minor effect were observed that might be related with inter-individual variation in human volunteers. This pharmacokinetic studies also indicated that the level of drug (Cmax) do not differ from previous studies in different races.
Odunayo, Adesola; Tobias, Karen M; Okafor, Chika C; Flatland, Bente
2017-11-01
OBJECTIVE To investigate the use of canine whole blood (WB) for measurement of ammonia concentration by use of a point-of-care ammonia meter and to compare results of measuring ammonia concentrations in WB, EDTA-anticoagulated WB, and plasma. ANIMALS 40 client-owned dogs. PROCEDURES A blood sample (2 mL) was obtained from each dog. One drop of WB was immediately applied to a test strip for evaluation with an ammonia meter. The remainder of the blood sample was placed in an EDTA-containing tube, and 1 drop of EDTA-anticoagulated WB was applied to a test strip. The remaining EDTA-anticoagulated WB sample was centrifuged, and the plasma was harvested and placed on ice. One drop of plasma was applied to a test strip; the remainder of the plasma sample was transported on ice and used for ammonia measurement with a reference laboratory instrument. All samples were tested within 1 hour after sample collection. Results were evaluated to detect significant differences in ammonia concentration. RESULTS Ammonia concentrations did not differ significantly between WB and EDTA-anticoagulated WB and between plasma samples measured with the meter and reference laboratory instrument. However, median ammonia concentration was significantly higher in plasma than in WB or EDTA-anti-coagulated WB. CONCLUSIONS AND CLINICAL RELEVANCE Anticoagulant-free WB was a valid sample for measurement by use of the ammonia meter. Plasma samples had higher ammonia concentrations than did WB samples. Results for each sample type should be interpreted by use of specimen- and method-specific reference intervals.
Tvedt, Tor Henrik Anderson; Rye, Kristin Paulsen; Reikvam, Håkon; Brenner, Annette K; Bruserud, Øystein
2015-03-01
Cytokines, soluble adhesion molecules and metalloproteinases can be detected in human serum or plasma samples. Such systemic levels are widely used as biomarkers in epidemiological and clinical studies. We prepared serum samples and three types of plasma samples (EDTA, heparin, citric acid) from 20 healthy individuals. The levels of 31 cytokines, four soluble adhesion molecules and eight matrix metalloproteinases were analyzed by Luminex technology. Most mediators showed detectable levels in both plasma and serum. Several mediators that can be released by platelets showed increased serum levels, especially CCL5 and CD40L, but for the other mediators the serum levels did not correlate with peripheral blood platelet counts and for these last mediators serum and plasma levels often showed strong correlations. The use of bivalirudin for anticoagulation significantly increased and citric acid combined with platelet inhibitors (ticagrelor, acetylsalicylic acid plus prostaglandin E2) did not alter plasma levels of platelet-store mediators compared with citric acid alone. The impact of sample preparation differed between mediators; for many mediators strong correlations were seen between serum and plasma levels even when absolute levels differed. Soluble adhesion molecule levels showed only minor differences between samples. Unsupervised hierarchical clustering suggested that the effect of sampling/preparation was strongest for serum and heparin plasma samples. Careful standardization of sample preparation is usually necessary when analyzing systemic mediator levels, and differences caused by sample preparation should be considered as a possible explanation if studies show conflicting results. Copyright © 2015 Elsevier B.V. All rights reserved.
Development of barrier coatings for cellulosic-based materials by cold plasma methods
NASA Astrophysics Data System (ADS)
Denes, Agnes Reka
Cellulose-based materials are ideal candidates for future industries that need to be based on environmentally safe technologies and renewable resources. Wood represents an important raw material and its application as construction material is well established. Cellophane is one of the most important cellulosic material and it is widely used as packaging material in the food industry. Outdoor exposure of wood causes a combination of physical and chemical degradation processes due to the combined effects of sunlight, moisture, fungi, and bacteria. Cold-plasma-induced surface modifications are an attractive way for tailoring the characteristics of lignocellulosic substrates to prevent weathering degradation. Plasma-polymerized hexamethyldisiloxane (PPHMDSO) was deposited onto wood surfaces to create water repellent characteristics. The presence of a crosslinked macromolecular structure was detected. The plasma coated samples exhibited very high water contact angle values indicating the existence of hydrophobic surfaces. Reflective and electromagnetic radiation-absorbent substances were incorporated with a high-molecular-weight polydimethylsiloxane polymer in liquid phase and deposited as thin layers on wood surfaces. The macromolecular films, containing the dispersed materials, were then converted into a three dimensional solid state network by exposure to a oxygen-plasma. It was demonstrated that both UV-absorbent and reflectant components incorporated into the plasma-generated PDMSO matrix protected the wood from weathering degradation. Reduced oxidation and less degradation was observed after simulated weathering. High water contact angle values indicated a strong hydrophobic character of the oxygen plasma-treated PDMSO-coated samples. Plasma-enhanced surface modifications and coatings were employed to create water-vapor barrier layers on cellophane substrate surfaces. HMDSO was selected as a plasma gas and oxygen was used to ablate amorphous regions. Oxygen plasma treated cellophane and oxygen plasma treated and PPHMDSO coated cellophane surfaces were comparatively analyzed and the corresponding surface wettability characteristics were evaluated. The plasma generated surface topographies controlled the morphology of the PPHMDSO layers. Higher temperature HMDSO plasma-state environments lead to insoluble, crosslinked layers. Continuous and pulsed Csb2Fsb6 plasmas were also used for surface modification and excellent surface fluorination was achieved under the pulsed plasma conditions.
McGee, C D; Greenwood, C E; Jeejeebhoy, K N
1990-01-01
The correction or maintenance of blood and tissue alpha-tocopherol (alpha-Toc) levels by intraperitoneally administered all-rac-alpha-tocopheryl acetate (alpha-Tac) was compared with RRR- alpha-tocopherol (alpha-Toc) in vitamin E-depleted and control rats. Rats received 1.3 TE vitamin E daily for 7 days. alpha-Tac was detected in plasma of one-third of alpha-Tac-treated rats 24 hr after the first treatment, although not in subsequent samplings. Both alpha-Tac and alpha-Toc increased tocopherol levels in plasma and liver of E-deprived rats, while little or no change was observed in adipose tissue and brain. Similarly, control rats treated with alpha-Tac or alpha-Toc had significantly greater (p less than 0.05) plasma and liver alpha-Toc levels at day 3 and day 7 than did saline-treated rats. There was no significant difference in adipose alpha-Toc levels among treatment groups of control rats. The results of this study suggest that alpha-Tac is rapidly hydrolyzed to its biologically active alcohol form and results in similar effects to that of intraperitoneally administered alpha-Toc.
Canullo, Luigi; Dehner, Jan Friedrich; Penarrocha, David; Checchi, Vittorio; Mazzoni, Annalisa; Breschi, Lorenzo
2016-01-01
The aim of this preliminary prospective RCT was to histologically evaluate peri-implant soft tissues around titanium abutments treated using different cleaning methods. Sixteen patients were randomized into three groups: laboratory customized abutments underwent Plasma of Argon treatment (Plasma Group), laboratory customized abutments underwent cleaning by steam (Steam Group), and abutments were used as they came from industry (Control Group). Seven days after the second surgery, soft tissues around abutments were harvested. Samples were histologically analyzed. Soft tissues surrounding Plasma Group abutments predominantly showed diffuse chronic infiltrate, almost no acute infiltrate, with presence of few polymorphonuclear neutrophil granulocytes, and a diffuse presence of collagenization bands. Similarly, in Steam Group, the histological analysis showed a high variability of inflammatory expression factors. Tissues harvested from Control Group showed presence of few neutrophil granulocytes, moderate presence of lymphocytes, and diffuse collagenization bands in some sections, while they showed absence of acute infiltrate in 40% of sections. However, no statistical difference was found among the tested groups for each parameter (p > 0.05). Within the limit of the present study, results showed no statistically significant difference concerning inflammation and healing tendency between test and control groups.
Chinnappan, Shobia; Ramachandrappa, Vijayakumar Shettikothanuru; Tamilarasu, Kadhiravan; Krishnan, Uma Maheswari; Pillai, Agiesh Kumar Balakrishna; Rajendiran, Soundravally
2016-04-01
Dengue cases were reported to undergo platelet activation and thrombocytopenia by a poorly understood mechanism. Recent studies suggested that Carica papaya leaf extract could recover the platelet count in dengue cases. However, no studies have attempted to unravel the mechanism of the plant extract in platelet recovery. Since there are no available drugs to treat dengue and considering the significance of C. papaya in dengue treatment, the current study aimed to evaluate two research questions: First one is to study if the C. papaya leaf extract exerts its action directly on platelets and second one is to understand if the extract can specifically inhibit the platelet aggregation during dengue viral infection. Sixty subjects with dengue positive and 60 healthy subjects were recruited in the study. Platelet-rich plasma (PRP) and platelet-poor plasma were prepared from both the dengue-infected and healthy control blood samples. Effect of the leaf extract obtained from C. papaya leaves was assessed on plasma obtained as well as platelets collected from both healthy and dengue-infected individuals. Platelet aggregation was significantly reduced when leaf extract preincubated with dengue plasma was added into control PRP, whereas no change in aggregation when leaf extract incubated-control plasma was added into control PRP. Upon direct addition of C. papaya leaf extract, both dengue PRP and control PRP showed a significant reduction in platelet aggregation. Within the dengue group, PRP from severe and nonsevere cases showed a significant decrease in aggregation without any difference between them. From the study, it is evident that C. papaya leaf extract can directly act on platelet. The present study, the first of its kind, found that the leaf extract possesses a dengue-specific neutralizing effect on dengue viral-infected plasma that may exert a protective role on platelets.
Phosphoproteins in extracellular vesicles as candidate markers for breast cancer
Chen, I-Hsuan; Xue, Liang; Hsu, Chuan-Chih; Paez, Juan Sebastian Paez; Pan, Li; Andaluz, Hillary; Wendt, Michael K.; Iliuk, Anton B.; Tao, W. Andy
2017-01-01
The state of protein phosphorylation can be a key determinant of cellular physiology such as early-stage cancer, but the development of phosphoproteins in biofluids for disease diagnosis remains elusive. Here we demonstrate a strategy to isolate and identify phosphoproteins in extracellular vesicles (EVs) from human plasma as potential markers to differentiate disease from healthy states. We identified close to 10,000 unique phosphopeptides in EVs isolated from small volumes of plasma samples. Using label-free quantitative phosphoproteomics, we identified 144 phosphoproteins in plasma EVs that are significantly higher in patients diagnosed with breast cancer compared with healthy controls. Several biomarkers were validated in individual patients using paralleled reaction monitoring for targeted quantitation. This study demonstrates that the development of phosphoproteins in plasma EV as disease biomarkers is highly feasible and may transform cancer screening and monitoring. PMID:28270605
Phosphoproteins in extracellular vesicles as candidate markers for breast cancer.
Chen, I-Hsuan; Xue, Liang; Hsu, Chuan-Chih; Paez, Juan Sebastian Paez; Pan, Li; Andaluz, Hillary; Wendt, Michael K; Iliuk, Anton B; Zhu, Jian-Kang; Tao, W Andy
2017-03-21
The state of protein phosphorylation can be a key determinant of cellular physiology such as early-stage cancer, but the development of phosphoproteins in biofluids for disease diagnosis remains elusive. Here we demonstrate a strategy to isolate and identify phosphoproteins in extracellular vesicles (EVs) from human plasma as potential markers to differentiate disease from healthy states. We identified close to 10,000 unique phosphopeptides in EVs isolated from small volumes of plasma samples. Using label-free quantitative phosphoproteomics, we identified 144 phosphoproteins in plasma EVs that are significantly higher in patients diagnosed with breast cancer compared with healthy controls. Several biomarkers were validated in individual patients using paralleled reaction monitoring for targeted quantitation. This study demonstrates that the development of phosphoproteins in plasma EV as disease biomarkers is highly feasible and may transform cancer screening and monitoring.
Hyung, Seok-Won; Piehowski, Paul D; Moore, Ronald J; Orton, Daniel J; Schepmoes, Athena A; Clauss, Therese R; Chu, Rosalie K; Fillmore, Thomas L; Brewer, Heather; Liu, Tao; Zhao, Rui; Smith, Richard D
2014-11-01
Removal of highly abundant proteins in plasma is often carried out using immunoaffinity depletion to extend the dynamic range of measurements to lower abundance species. While commercial depletion columns are available for this purpose, they generally are not applicable to limited sample quantities (<20 μL) due to low yields stemming from losses caused by nonspecific binding to the column matrix and concentration of large eluent volumes. Additionally, the cost of the depletion media can be prohibitive for larger-scale studies. Modern LC-MS instrumentation provides the sensitivity necessary to scale-down depletion methods with minimal sacrifice to proteome coverage, which makes smaller volume depletion columns desirable for maximizing sample recovery when samples are limited, as well as for reducing the expense of large-scale studies. We characterized the performance of a 346 μL column volume microscale depletion system, using four different flow rates to determine the most effective depletion conditions for ∼6-μL injections of human plasma proteins and then evaluated depletion reproducibility at the optimum flow rate condition. Depletion of plasma using a commercial 10-mL depletion column served as the control. Results showed depletion efficiency of the microscale column increased as flow rate decreased, and that our microdepletion was reproducible. In an initial application, a 600-μL sample of human cerebrospinal fluid (CSF) pooled from multiple sclerosis patients was depleted and then analyzed using reversed phase liquid chromatography-mass spectrometry to demonstrate the utility of the system for this important biofluid where sample quantities are more commonly limited.
Hyung, Seok Won; Piehowski, Paul D.; Moore, Ronald J.; ...
2014-09-06
Removal of highly abundant proteins in plasma is often carried out using immunoaffinity depletion to extend the dynamic range of measurements to lower abundance species. While commercial depletion columns are available for this purpose, they generally are not applicable to limited sample quantities (<20 µL) due to low yields stemming from losses caused by nonspecific binding to the column matrix. Additionally, the cost of the depletion media can be prohibitive for larger scale studies. Modern LC-MS instrumentation provides the sensitivity necessary to scale-down depletion methods with minimal sacrifice to proteome coverage, which makes smaller volume depletion columns desirable for maximizingmore » sample recovery when samples are limited, as well as for reducing the expense of large scale studies. We characterized the performance of a 346 µL column volume micro-scale depletion system, using four different flow rates to determine the most effective depletion conditions for ~6 μL injections of human plasma proteins and then evaluated depletion reproducibility at the optimum flow rate condition. Depletion of plasma using a commercial 10 mL depletion column served as the control. Results showed depletion efficiency of the micro-scale column increased as flow rate decreased, and that our micro-depletion was reproducible. We found, in an initial application, a 600 µL sample of human cerebral spinal fluid (CSF) pooled from multiple sclerosis patients was depleted and then analyzed using reversed phase liquid chromatography-mass spectrometry to demonstrate the utility of the system for this important biofluid where sample quantities are more commonly limited.« less
Park, Min-Ho; Lee, Yun Young; Cho, Kyung Hee; La, Sookie; Lee, Hee Joo; Yim, Dong-Seok; Ban, Sooho; Park, Moon-Young; Kim, Yong-Chul; Kim, Yoon-Gyoon; Shin, Young G
2016-03-01
A liquid chromatography-triple quadrupole mass spectrometric (LC-MS/MS) method was developed and validated for the determination of 5-nitro-5'-hydroxy-indirubin-3'-oxime (AGM-130) in human plasma to support a microdose clinical trial. The method consisted of a liquid-liquid extraction for sample preparation and LC-MS/MS analysis in the positive ion mode using TurboIonSpray(TM) for analysis. d3 -AGM-130 was used as the internal standard. A linear regression (weighted 1/concentration) was used to fit calibration curves over the concentration range of 10-2000 pg/mL for AGM-130. There were no endogenous interference components in the blank human plasma tested. The accuracy at the lower limit of quantitation was 96.6% with a precision (coefficient of variation, CV) of 4.4%. For quality control samples at 30, 160 and 1600 pg/mL, the between run CV was ≤5.0 %. Between-run accuracy ranged from 98.1 to 101.0%. AGM-130 was stable in 50% acetonitrile for 168 h at 4°C and 6 h at room temperature. AGM-130 was also stable in human plasma at room temperature for 6 h and through three freeze-thaw cycles. The variability of selected samples for the incurred sample reanalysis was ≤12.7% when compared with the original sample concentrations. This validated LC-MS/MS method for determination of AGM-130 was used to support a phase 0 microdose clinical trial. Copyright © 2015 John Wiley & Sons, Ltd.
Scarpelini, Bruno; Zanoni, Michelle; Sucupira, Maria Cecilia Araripe; Truong, Hong-Ha M.; Janini, Luiz Mario Ramos; Segurado, Ismael Dale Cotrin; Diaz, Ricardo Sobhie
2016-01-01
Background We evaluated plasma samples HIV-infected individuals with different phenotypic profile among five HIV-infected elite controllers and five rapid progressors after recent HIV infection and one year later and from 10 individuals subjected to antiretroviral therapy, five of whom were immunological non-responders (INR), before and after one year of antiretroviral treatment compared to 175 samples from HIV-negative patients. A targeted quantitative tandem mass spectrometry metabolomics approach was used in order to determine plasma metabolomics biosignature that may relate to HIV infection, pace of HIV disease progression, and immunological response to treatment. Results Twenty-five unique metabolites were identified, including five metabolites that could distinguish rapid progressors and INRs at baseline. Severe deregulation in acylcarnitine and sphingomyelin metabolism compatible with mitochondrial deficiencies was observed. β-oxidation and sphingosine‐1‐phosphate-phosphatase-1 activity were down-regulated, whereas acyl-alkyl-containing phosphatidylcholines and alkylglyceronephosphate synthase levels were elevated in INRs. Evidence that elite controllers harbor an inborn error of metabolism (late-onset multiple acyl-coenzyme A dehydrogenase deficiency [MADD]) was detected. Conclusions Blood-based markers from metabolomics show a very high accuracy of discriminating HIV infection between varieties of controls and have the ability to predict rapid disease progression or poor antiretroviral immunological response. These metabolites can be used as biomarkers of HIV natural evolution or treatment response and provide insight into the mechanisms of the disease. PMID:27941971
Yang, Yimin; Ying, Sha; Li, Te; Zhen, Juan; Chen, Dongmei; Wang, Jianmeng
2018-04-14
A selective and sensitive liquid chromatography tandem mass spectrometry method was developed for the simultaneous determination of salviaflaside and rosmarinic acid in rat plasma. Sample preparation was carried out through liquid-liquid extraction with ethyl acetate using curculigoside as internal standard (IS). The analytes were determined by selected reaction monitoring operated in the positive ESI mode. Chromatographic separation was performed on an Agilent Eclipse Plus C 18 column (100 × 4.6 mm, 1.8 μm) with a mobile phase consisting of methanol-water-formic acid (50:50:0.1, v/v/v) at a flow rate of 0.3 mL/min. The run time was 1.9 min per sample and the injection volume was 5 μL. The method had an LLOQ of 1.6 ng/mL for salviaflaside and 0.94 ng/mL for rosmarinic acid in plasma. The linear calibration curves were fitted over the range of 1.6-320 ng/mL for salviaflaside and 0.94-188 ng/mL for rosmarinic acid in plasma with correlation coefficients (r 2 ) >0.99. Intra- and inter-day precisions (relative standard deviation) were < 13.5%, and accuracies (relative error) were between -8.6% and 14.5% for all quality control samples. The method was validated and applied to the pharmacokinetics of salviaflaside and rosmarinic acid in plasma after oral administration of Prunella vulgaris extract to rats. Copyright © 2018 John Wiley & Sons, Ltd.
Prickett, Claire D.; Lister, E.; Collins, Michelle; Trevithick-Sutton, C. C.; Hirst, M.; Vinson, J. A.; Noble, E.; Trevithick, J. R.
2004-01-01
Objectives: To correlate the oxidative state of postabsorptive blood plasma after consumption of one or three drinks of different beverages with known J-shaped epidemiological risk curves. Design, interventions, and main outcome measures: Red wine, lager beer, stout (alcoholic and alcohol-free), with antioxidant activity, and an aqueous solution of alcohol were compared for the plasma antioxidant or pro-oxidant activity in human volunteers following consumption of one or three typical drinks containing equivalent amounts of alcohol (except for an alcohol-free stout used as a control for stout). Results: One drink of red wine, lager beer, or stout (5% alcohol v/v, and alcohol-free) significantly increased the average antioxidant activity in plasma samples obtained from volunteers averaged over 240 min. Three drinks of red wine, lager beer, or stout (5% alcohol v/v, and alcohol-free) significantly increased the average pro-oxidant activity in plasma samples obtained from volunteers averaged over 360 min. For a solution of alcohol, three drinks resulted in pro-oxidant plasma on average, whereas while one drink did not significantly affect the plasma oxidative status. A preliminary experiment in which two volunteers showed a significantly increased time to metabolize ethanol after ingestion resulted in elevated antioxidant activity in plasma for lager beer and red wine. Conclusions: One drink of red wine, beer, or stout provided equivalent increases in plasma antioxidant activity. Three drinks of red wine, beer, or stout provided equivalent increases in plasma pro-oxidant activity. This may explain, at least in part, the decreased risk of cataract and atherosclerosis from daily consumption of one drink of different types of alcoholic beverages as well as the increased risk from daily consumption of three drinks of alcoholic beverages. The plasma pro-oxidant activity appears to be due to ethanol metabolism, whereas the antioxidant activity may be due to the absorption of polyphenols in the beverages. PMID:19330151
Use of vitamin B12 in joint lavage for determination of dilution factors of canine synovial fluid.
de Bruin, Tanya; de Rooster, Hilde; van Bree, Henri; Cox, Eric
2005-11-01
To test a modified saline (0.9% NaCl) solution joint washing (lavage) technique that includes the use of vitamin B12 as an internal marker for the evaluation of synovial fluid dilution in lavage samples from canine joints. 9 plasma samples obtained from blood samples of 9 healthy dogs and 9 synovial fluid samples aspirated from stifle joints of 9 cadaveric dogs. Photometric absorbances of 25% vitamin B12 solution, canine synovial fluid, and canine plasma were measured in a spectrophotometer to establish an optimal wavelength for analysis. Canine synovial fluid and plasma samples were mixed with the 25% vitamin B12 solution to obtain 1%, 3%, 5%, 10%, 20%, and 50% solutions of synovial fluid or plasma. Diluted synovial fluid and plasma samples were used to simulate joint lavage samples and to examine the possible interference of these substances (synovial fluid or plasma) with the absorbance of the 25% vitamin B12 solution in photometric analysis. The optimal wavelength was found to be at 550 nm. Canine synovial fluid and plasma samples did not interfere with the absorbance measurements of the 25% vitamin B12 solution up to a 50% dilution of plasma or synovial fluid. The modified saline solution joint lavage method with the use of a 25% vitamin B12 solution as an internal standard provides an accurate and reliable technique for the evaluation of synovial fluid dilution in lavage samples from canine joints.
DiMES PMI research at DIII-D in support of ITER and beyond
Rudakov, Dimitry L.; Abrams, Tyler; Ding, Rui; ...
2017-03-27
An overview of recent Plasma-Material Interactions (PMI) research at the DIII-D tokamak using the Divertor Material Evaluation System (DiMES) is presented. The DiMES manipulator allows for exposure of material samples in the lower divertor of DIII-D under well-diagnosed ITER-relevant plasma conditions. Plasma parameters during the exposures are characterized by an extensive diagnostic suite including a number of spectroscopic diagnostics, Langmuir probes, IR imaging, and Divertor Thomson Scattering. Post-mortem measurements of net erosion/deposition on the samples are done by Ion Beam Analysis, and results are modelled by the ERO and REDEP/WBC codes with plasma background reproduced by OEDGE/DIVIMP modelling based onmore » experimental inputs. This article highlights experiments studying sputtering erosion, re-deposition and migration of high-Z elements, mostly tungsten and molybdenum, as well as some alternative materials. Results are generally encouraging for use of high-Z PFCs in ITER and beyond, showing high redeposition and reduced net sputter erosion. Two methods of high-Z PFC surface erosion control, with (i) external electrical biasing and (ii) local gas injection, are also discussed. Furthermore, these techniques may find applications in the future devices.« less
NASA Astrophysics Data System (ADS)
Herbert, P. A. F.; Jaroszyńska-Wolińska, J.
2011-07-01
An atmospheric pressure non-thermal equilibrium pin corona plasma jet was used to deposit polymeric coatings from monomer precursor in both vapour and liquid aerosol states to allow a direct comparison of the quality and performance of the as-deposited coatings, specifically with respect to the achievement of soft plasma polymerisation (SPP) where the coating exhibits minimal fragmentation or damage to the monomer molecule while, at the same time, being highly cross-linked. A long chain perfluorocarbon molecule was introduced into the helium plasma and coatings deposited at rates of up to 50 nm/min. XPS, FTIR, contact angle and ellipsometric measurements indicated that a controlled polymerisation reaction had taken place in the case of the vapour deposited samples through the vinyl group of the monomer, with only minor fragmentation of the functional perfluoro chain. Furthermore, a high level of cross-linking was achieved and the coatings were stable to a toluene wash. In contrast, while the liquid deposition samples showed good retention of monomer molecular structure, they exhibited negligible cross-linking and were readily removed by immersion in toluene rendering them functionally useless.
Simon, Krzysztof Adam; Pazgan-Simon, Monika
2015-01-01
Aim of the study To determine plausible associations between liver cirrhosis and circulating endothelial cell-derived microparticles (EMPs), vascular endothelial growth factor (VEGF) levels and plasma nitric oxide (NO) metabolites. Material and methods Sixty patients with cirrhosis and 20 healthy control subjects were enrolled in the study. Circulating EMPs from platelet-poor plasma samples were examined by flow cytometry. These microparticles were categorized into endothelial cell-derived activated MPs (EMP-ac) (CD31+ CD42b– AN-V–) and endothelial cell-derived apoptotic MPs (EMP-ap) (CD31+ CD42b– AN-V+). Plasma VEGF levels were measured by enzyme-linked immunosorbent assay. Plasma NO metabolites (NOx–) levels were determined using a Greiss reaction method. Results Compared with the healthy control subjects, the patients with cirrhosis showed a significant increase in plasma levels of both phenotypes of EMPs. When the presence of ascites was considered, the plasma levels of EMP-ap were higher (p < 0.01), as well as NOx– (p < 0.05). EMP-ap positively correlated with VEGF level in all cirrhotic patients and this correlation was stronger in decompensated cirrhotic patients. In multivariate logistic regression analysis, the independent factors associated with the presence of ascites were high EMP-ap levels and elevated VEGF levels. Conclusions Elevated plasma levels of EMP-ap in addition to high levels of VEGF might be considered as valuable parameters for predicting the occurrence of ascites in cirrhotic patients. PMID:28856256
Weiss, Gunter; Schlegel, Anne; Kottwitz, Denise; König, Thomas; Tetzner, Reimo
2017-01-01
Low-dose computed tomography (LDCT) is used for screening for lung cancer (LC) in high-risk patients in the United States. The definition of high risk and the impact of frequent false-positive results of low-dose computed tomography remains a challenge. DNA methylation biomarkers are valuable noninvasive diagnostic tools for cancer detection. This study reports on the evaluation of methylation markers in plasma DNA for LC detection and discrimination of malignant from nonmalignant lung disease. Circulating DNA was extracted from 3.5-mL plasma samples, treated with bisulfite using a commercially available kit, purified, and assayed by real-time polymerase chain reaction for assessment of DNA methylation of short stature homeobox 2 gene (SHOX2), prostaglandin E receptor 4 gene (PTGER4), and forkhead box L2 gene (FOXL2). In three independent case-control studies these assays were evaluated and optimized. The resultant assay, a triplex polymerase chain reaction combining SHOX2, PTGER4, and the reference gene actin, beta gene (ACTB), was validated using plasma from patients with and without malignant disease. A panel of SHOX2 and PTGER4 provided promising results in three independent case-control studies examining a total of 330 plasma specimens (area under the receiver operating characteristic curve = 91%-98%). A validation study with 172 patient samples demonstrated significant discriminatory performance in distinguishing patients with LC from subjects without malignancy (area under the curve = 0.88). At a fixed specificity of 90%, sensitivity for LC was 67%; at a fixed sensitivity of 90%, specificity was 73%. Measurement of SHOX2 and PTGER4 methylation in plasma DNA allowed detection of LC and differentiation of nonmalignant diseases. Development of a diagnostic test based on this panel may provide clinical utility in combination with current imaging techniques to improve LC risk stratification. Copyright © 2016 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.
Sonker, Atul; Dubey, Anju; Bhatnagar, Ankur; Chaudhary, Rajendra
2015-01-01
Platelets are a source of numerous growth factors which facilitate repair and healing. Thus platelet rich plasma has been increasingly used as a treatment modality in the field of reconstructive surgeries for wound healing. This preliminary study was carried out to explore whether platelet growth factors from platelet rich plasma could be used for enhancement of split thickness skin graft survival. Twenty patients (13 males and 7 females) requiring split thickness skin graft for various clinical reasons were enrolled in the study. Platelet rich plasma was collected by apheresis and frozen at -80° C. It was thawed at room temperature immediately before its intended application. PRP was applied only on one half of the wound, while another half served as control. Patient was followed for 6 weeks. The effect was assessed at first dressing in terms of graft uptake and subsequently as time taken for complete healing. There was 100% uptake of the graft in the area where platelet rich plasma was applied. In the control area, there was complete graft loss in 4 cases, partial loss in 7 cases and complete uptake in 9 cases. This study demonstrated promising results on application of PRP to split thickness skin grafts. Further randomized studies with greater sample size may be undertaken to establish platelet rich plasma as a validated treatment modality.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ding, R.; Rudakov, D. L.; Stangeby, P. C.
Dedicated DIII-D experiments coupled with modeling reveal that the net erosion rate of high-Z materials, i.e. Mo and W, is strongly affected by carbon concentration in the plasma and the magnetic pre-sheath properties. We have investigated different methods such as electrical biasing and local gas injection to control high-Z material erosion. The net erosion rate of high-Z materials is significantly reduced due to the high local re-deposition ratio. The ERO modeling shows that the local re-deposition ratio is mainly controlled by the electric field and plasma density within the magnetic pre-sheath. The net erosion can be significantly suppressed by reducingmore » the sheath potential drop. A high carbon impurity concentration in the background plasma is also found to reduce the net erosion rate of high-Z materials. Both DIII-D experiments and modeling show that local 13CH 4 injection can create a carbon coating on the metal surface. The profile of 13C deposition provides quantitative information on radial transport due to E × B drift and the cross-field diffusion. The deuterium gas injection upstream of the W sample can reduce W net erosion rate by plasma perturbation. The inter-ELM W erosion we measured in H-mode plasmas, rates at different radial locations are well reproduced by ERO modeling taking into account charge-state-resolved carbon ion flux in the background plasma calculated using the OEDGE code.« less
NASA Astrophysics Data System (ADS)
Forsythe, V. V.; Makarevich, R. A.
2016-12-01
Small-scale ionospheric plasma irregularities in the high-latitude E region and their control by F-region plasma convection are investigated using Super Dual Auroral Network (SuperDARN) observations at high southern latitudes over a 1-year period. Significant asymmetries are found in the velocity occurrence distribution due to the clustering of the high-velocity echoes of a particular velocity polarity. Statistical analysis of convection showed that some radars observe predominantly negative bias in the convection component within their short, E-region ranges, while others have a predominantly positive bias. A hypothesis that this bias is caused by asymmetric sectoring of the high-latitude plasma convection pattern is investigated. A new algorithm is developed that samples the plasma convection map and evaluates the convection pattern asymmetry along the particular latitude that corresponds to the radar location. It is demonstrated that the convection asymmetry has a particular seasonal and diurnal pattern, which is different for the polar and auroral radars. Possible causes for the observed convection pattern asymmetry are discussed. It is further proposed that the statistical occurrence of high-velocity E-region echoes generated by the Farley-Buneman instability (FBI) is highly sensitive to small changes in the convection pattern, which is consistent with the electric field threshold for the FBI onset being perhaps sharper and lower than previously thought.
Brede, Edna; Wilhelm, Michael; Göen, Thomas; Müller, Johannes; Rauchfuss, Knut; Kraft, Martin; Hölzer, Jürgen
2010-06-01
Residents in Arnsberg, Germany, had been supplied by drinking water contaminated with perfluorooctanoate (PFOA). Biomonitoring data from 2006 evidenced that plasma PFOA concentrations of residents from Arnsberg were 4.5-8.3 times higher than those in reference groups. The introduction of charcoal filtration in July 2006 distinctly reduced PFOA concentrations in drinking water. Our one-year follow-up study showed a 10-20% reduction of PFOA plasma levels in residents from Arnsberg. Here we report the first results of the two-year follow-up study Arnsberg 2008. Additionally, the results of the two-year follow-up examination of the reference group are included. Paired plasma samples of 138 study participants (45 children, 46 mothers and 47 men) collected in 2006 and 2008 were considered in the statistical analyses. Within the two years plasma concentrations of PFOA, perfluorooctanesulfonate (PFOS) and perfluorohexanesulfonate (PFHxS) decreased in residents from Arnsberg and in control groups. The geometric means of PFOA plasma levels declined by 39% (children and mothers) and 26% (men) in Arnsberg and by 13-15% in the corresponding subgroups from the reference areas. For the population from Arnsberg a geometric mean plasma PFOA half-life of 3.26 years (range 1.03-14.67 years) was calculated. Our results confirm an ongoing reduction of the PFOA load in residents from Arnsberg. The decline of PFC levels in plasma of participants from the reference areas reflects the general decrease of human PFC exposure during the very recent years. Copyright 2010 Elsevier GmbH. All rights reserved.
Suwiwat, Supaporn; Pradutkanchana, Jintana; Ishida, Takafumi; Mitarnun, Winyou
2007-12-01
The level of circulating EBV DNA is a prognostic marker in patients with some EBV-associated malignant diseases. To investigate the presence and nature of Epstein-Barr virus (EBV) DNA in the plasma and to evaluate the correlation of plasma concentrations of EBV DNA with the EBV genomic status in peripheral blood T-cells and neoplastic cells and with the clinical outcome of patients with peripheral T-cell and NK-cell lymphomas (PTCL) and peripheral T-cell proliferative diseases (PTPD). EBV DNA in the plasma of 45 patients and 45 controls was measured using real-time PCR. The presence of the EBV genome in the isolated peripheral blood lymphocytes (CD3+ and CD3- cells) was analysed by PCR. Detection of EBV-encoded early RNA (EBER) in corresponding tumor tissues was carried out using in situ hybridization. DNase I digestion was applied to plasma samples to detect naked EBV DNA. Cell-free EBV DNA was detected in 32/38 (84%) of PTCL patients and 5/7 (71%) of PTPD patients, but not in the controls. Patients with EBV genome in peripheral blood CD3+ cells and EBV genome (EBER) in the tumor cells, compared to those without these findings, had significantly higher plasma EBV DNA levels. The majority of circulating EBV DNA molecules was naked form. The plasma EBV DNA levels were not related to survival. The concentration of EBV DNA in the plasma was not a prognostic marker in PTCL and PTPD patients.
Bacteria-killing ability of fresh blood plasma compared to frozen blood plasma
Jacobs, Anne C.; Fair, Jeanne Marie
2015-10-09
In recent years, the bacteria-killing assay (BKA) has become a popular technique among ecoimmunologists. New variations of that assay allow researchers to use smaller volumes of blood, an important consideration for those working on small-bodied animals. However, this version of the assay requires access to a lab with a nanodrop spectrophotometer, something that may not be available in the field. One possible solution is to freeze plasma for transport; however, this assumes that frozen plasma samples will give comparable results to fresh ones. Here, we tested this assumption using plasma samples from three species of birds: chickens (Gallus gallus), ash-throatedmore » flycatchers (Myiarchus cinerascens), and western bluebirds (Sialia mexicana). Chicken plasma samples lost most or all of their bacterial killing ability after freezing. This did not happen in flycatchers and bluebirds; however, frozen plasma did not produce results comparable to those obtained using fresh plasma. Finally, we caution researchers using the BKA to use fresh samples whenever possible, and to validate the use of frozen samples on a species-by-species basis.« less
NASA Astrophysics Data System (ADS)
Chinnov, V. F.; Sargsyan, M. A.; Gadzhiev, M. Kh; Khromov, M. A.; Kavyrshin, D. I.; Chistolinov, A. V.
2018-01-01
In an automated measuring complex using optical and spectral methods the spatial and temporal changes in the parameters and composition of nitrogen plasma jet were investigated. The plasma jet was flowing out of the nozzle of the plasma torch with 10-12 kK temperature and acting on the sample of MPG-6 graphite. Due to the heating of the sample to the temperatures of 2.5-3 kK the influence of the sublimating material of the sample on the plasma composition and temperature in the near-surface region of the sample was investigated. An original method based on the analysis of movement of optical inhomogeneities in the plasma flow was used to estimate the plasma jet velocity in the region where it interacts with the sample. The combined analysis of the results of two-positioning video recordings opens up the possibility of determining spatial-temporal distributions of the plasma jet velocities, in medium and high pressure environments, in the ranges from few to thousands of m/s and 3-15 kK temperatures.
Bacteria-killing ability of fresh blood plasma compared to frozen blood plasma.
Jacobs, Anne C; Fair, Jeanne M
2016-01-01
In recent years, the bacteria-killing assay (BKA) has become a popular technique among ecoimmunologists. New variations of that assay allow researchers to use smaller volumes of blood, an important consideration for those working on small-bodied animals. However, this version of the assay requires access to a lab with a nanodrop spectrophotometer, something that may not be available in the field. One possible solution is to freeze plasma for transport; however, this assumes that frozen plasma samples will give comparable results to fresh ones. We tested this assumption using plasma samples from three species of birds: chickens (Gallus gallus), ash-throated flycatchers (Myiarchus cinerascens), and western bluebirds (Sialia mexicana). Chicken plasma samples lost most or all of their bacterial killing ability after freezing. This did not happen in flycatchers and bluebirds; however, frozen plasma did not produce results comparable to those obtained using fresh plasma. We caution researchers using the BKA to use fresh samples whenever possible, and to validate the use of frozen samples on a species-by-species basis. Copyright © 2015 Elsevier Inc. All rights reserved.
Bacteria-killing ability of fresh blood plasma compared to frozen blood plasma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jacobs, Anne C.; Fair, Jeanne Marie
In recent years, the bacteria-killing assay (BKA) has become a popular technique among ecoimmunologists. New variations of that assay allow researchers to use smaller volumes of blood, an important consideration for those working on small-bodied animals. However, this version of the assay requires access to a lab with a nanodrop spectrophotometer, something that may not be available in the field. One possible solution is to freeze plasma for transport; however, this assumes that frozen plasma samples will give comparable results to fresh ones. Here, we tested this assumption using plasma samples from three species of birds: chickens (Gallus gallus), ash-throatedmore » flycatchers (Myiarchus cinerascens), and western bluebirds (Sialia mexicana). Chicken plasma samples lost most or all of their bacterial killing ability after freezing. This did not happen in flycatchers and bluebirds; however, frozen plasma did not produce results comparable to those obtained using fresh plasma. Finally, we caution researchers using the BKA to use fresh samples whenever possible, and to validate the use of frozen samples on a species-by-species basis.« less
Visible camera imaging of plasmas in Proto-MPEX
NASA Astrophysics Data System (ADS)
Mosby, R.; Skeen, C.; Biewer, T. M.; Renfro, R.; Ray, H.; Shaw, G. C.
2015-11-01
The prototype Material Plasma Exposure eXperiment (Proto-MPEX) is a linear plasma device being developed at Oak Ridge National Laboratory (ORNL). This machine plans to study plasma-material interaction (PMI) physics relevant to future fusion reactors. Measurements of plasma light emission will be made on Proto-MPEX using fast, visible framing cameras. The cameras utilize a global shutter, which allows a full frame image of the plasma to be captured and compared at multiple times during the plasma discharge. Typical exposure times are ~10-100 microseconds. The cameras are capable of capturing images at up to 18,000 frames per second (fps). However, the frame rate is strongly dependent on the size of the ``region of interest'' that is sampled. The maximum ROI corresponds to the full detector area, of ~1000x1000 pixels. The cameras have an internal gain, which controls the sensitivity of the 10-bit detector. The detector includes a Bayer filter, for ``true-color'' imaging of the plasma emission. This presentation will exmine the optimized camera settings for use on Proto-MPEX. This work was supported by the US. D.O.E. contract DE-AC05-00OR22725.
Femtosecond self-reconfiguration of laser-induced plasma patterns in dielectrics
NASA Astrophysics Data System (ADS)
Déziel, Jean-Luc; Dubé, Louis J.; Messaddeq, Sandra H.; Messaddeq, Younès; Varin, Charles
2018-05-01
Laser-induced modification of transparent solids by intense femtosecond laser pulses allows fast integration of nanophotonic and nanofluidic devices with controlled optical properties. Experimental observations suggest that the local and dynamic nature of the interactions between light and the transient plasma plays an important role during fabrication. Current analytical models neglect these aspects and offer limited coverage of nanograting formation on dielectric surfaces. In this paper, we present a self-consistent dynamic treatment of the plasma buildup and its interaction with light within a three-dimensional electromagnetic framework. The main finding of this work is that local light-plasma interactions are responsible for the reorientation of laser-induced periodic plasma patterns with respect to the incident light polarization, when a certain energy density threshold is reached. Plasma reconfiguration occurs within a single laser pulse, on a femtosecond time scale. Moreover, we show that the reconfigured subwavelength plasma structures actually grow into the bulk of the sample, which agrees with the experimental observations of self-organized volume nanogratings. We find that mode coupling of the incident and transversely scattered light with the periodic plasma structures is sufficient to initiate the growth and self-organization of the pattern inside the medium with a characteristic half-wavelength periodicity.
NASA Astrophysics Data System (ADS)
Liu, L. F.; Chen, Y. Y.; Ye, Z. H.; Hu, X. N.; Ding, R. J.; He, L.
2018-03-01
Plasma etching is a powerful technique for transferring high-resolution lithographic patterns into HgCdTe material with low etch-induced damage, and it is important for fabricating small-pixel-size HgCdTe infrared focal plane array (IRFPA) detectors. P- to n-type conversion is known to occur during plasma etching of vacancy-doped HgCdTe; however, it is usually unwanted and its removal requires extra steps. Etching at cryogenic temperatures can reduce the etch-induced type conversion depth in HgCdTe via the electrical damage mechanism. Laser beam-induced current (LBIC) is a nondestructive photoelectric characterization technique which can provide information regarding the vertical and lateral electrical field distribution, such as defects and p-n junctions. In this work, inductively coupled plasma (ICP) etching of HgCdTe was implemented at cryogenic temperatures. For an Ar/CH4 (30:1 in SCCM) plasma with ICP input power of 1000 W and RF-coupled DC bias of ˜ 25 V, a HgCdTe sample was dry-etched at 123 K for 5 min using ICP. The sample was then processed to remove a thin layer of the plasma-etched region while maintaining a ladder-like damaged layer by continuously controlling the wet chemical etching time. Combining the ladder etching method and LBIC measurement, the ICP etching-induced electrical damage depth was measured and estimated to be about 20 nm. The results indicate that ICP etching at cryogenic temperatures can significantly suppress plasma etching-induced electrical damage, which is beneficial for defining HgCdTe mesa arrays.
Kim, So-Hyun; K. Cho, Somi; Min, Tae-Sun; Kim, Yujin; Yang, Seung-Ok; Kim, Hee-Su; Hyun, Sun-Hee; Kim, Hana; Kim, Young-Suk; Choi, Hyung-Kyoon
2011-01-01
The ameliorating effects of Mango (Mangifera indica L.) flesh and peel samples on plasma ethanol level were investigated using a mouse model. Mango fruit samples remarkably decreased mouse plasma ethanol levels and increased the activities of alcohol dehydrogenase and acetaldehyde dehydrogenase. The 1H-NMR-based metabolomic technique was employed to investigate the differences in metabolic profiles of mango fruits, and mouse plasma samples fed with mango fruit samples. The partial least squares-discriminate analysis of 1H-NMR spectral data of mouse plasma demonstrated that there were clear separations among plasma samples from mice fed with buffer, mango flesh and peel. A loading plot demonstrated that metabolites from mango fruit, such as fructose and aspartate, might stimulate alcohol degradation enzymes. This study suggests that mango flesh and peel could be used as resources for functional foods intended to decrease plasma ethanol level after ethanol uptake. PMID:21562641
Shah, Priyanka A; Shah, Jaivik V; Sanyal, Mallika; Shrivastav, Pranav S
2017-03-01
A specific and rapid liquid chromatography-tandem mass spectrometry method is proposed for the simultaneous determination of metformin (MET), saxagliptin (SAXA) and its active metabolite, 5-hydroxy saxagliptin (5-OH SAXA) in human plasma. Sample preparation was accomplished from 50 μL plasma sample by solid-phase extraction using sodium dodecyl sulfate as an ion-pair reagent. Reversed-phase chromatographic resolution of analytes was possible within 3.5 min on ACE 5CN (150 × 4.6 mm, 5 μm) column using acetonitrile and10.0 mm ammonium formate buffer, pH 5.0 (80:20, v/v) as the mobile phase. Triple quadrupole mass spectrometric detection was performed using electrospray ionization in the positive ionization mode. The calibration curves showed good linearity (r 2 ≥ 0.9992) over the established concentration range with limit of quantification of 1.50, 0.10 and 0.20 ng/mL for MET, SAXA and 5-OH SAXA respectively. The extraction recoveries obtained from spiked plasma samples were highly consistent for MET (75.12-77.84%), SAXA (85.90-87.84%) and 5-OH SAXA (80.32-82.69%) across quality controls. The validated method was successfully applied to a bioequivalence study with a fixed-dose formulation consisting of 5 mg SAXA and 500 mg MET in 18 healthy subjects. The reproducibility of the assay was demonstrated by reanalysis of 87 incurred samples. Copyright © 2016 John Wiley & Sons, Ltd.
Jiang, Hongliang; Wang, Yurong; Shet, Manjunath S; Zhang, Yang; Zenke, Duane; Fast, Douglas M
2011-09-01
A rapid, specific, and reliable LC-MS/MS based bioanalytical method was developed and validated for the simultaneous determination of naloxone (NLX) and its two metabolites, 6β-naloxol (NLL) and naloxone-3β-D-glucuronide (NLG) in mouse plasma. The optimal chromatographic behavior of these analytes was achieved on an Aquasil C18 column (50 mm × 2.1 mm, 5 μm) using reversed phase chromatography. The total LC analysis time per injection was 2.5 min with a flow rate of 1.0 mL/min with gradient elution. Sample preparation via protein precipitation with acetonitrile in a 96-well format was applied for analyses of these analytes. The analytes were monitored by electrospray ionization in positive ion multiple reaction monitoring (MRM) mode. Modification of collision energy besides chromatographic separation was applied to further eliminate interference peaks for NLL and NLG. The method validation was conducted over the curve range of 0.200/0.400/0.500 to 100/200/250 ng/mL for NLX/NLL/NLG, respectively, using 0.0250 mL of plasma sample. The intra- and inter-day precision and accuracy of the quality control samples at low, medium, and high concentration levels showed ≤ 6.5% relative standard deviation (RSD) and -8.3 to -2.5% relative error (RE). The method was successfully applied to determine the concentrations of NLX, NLL, and NLG in incurred mouse plasma samples. Copyright © 2011 Elsevier B.V. All rights reserved.
1992-05-15
The laboratory heterogeneity of the lupus anticoagulant (LA) was investigated in a multicentre study using a panel of 78 plasma samples diagnosed as containing a LA. Consecutive samples were collected by 12 participants using various screening tests, and sent to 7 laboratories which performed one or more clotting assays among the following: activated partial thromboplastin time (APTT), dilute Russell viper venom time, kaolin clotting time (KCT), dilute tissue thromboplastin time (dTTI) and a platelet neutralization test. For APTT and dTTI, 10 versions of these tests including standard and mixing procedures were carried out. They varied by reagents, phospholipid concentration or methodology. Cut-off times were determined for each test by comparing the results of the panel to those of a control population. When the data of all clotting assays were pooled, 70 of the 78 selected plasmas were considered to contain LA, 15 of them having a low-titer inhibitor. Sensitivity, defined as the proportion of positive results among LA-containing plasmas, varied from 62 to 100% and was positively related to responsiveness (defined as the mean ratio of clotting time to cut-off time). Laboratory heterogeneity of LA-containing plasma was illustrated by a star symbol plot analysis. Different populations of samples, with LA preferentially recognized by one assay (or group of assays) irrespective of the overall sensitivity of this assay, were identified. Multiple component analysis demonstrated the heterogeneity of low-titer inhibitors, which complicates their recognition in routine laboratory investigation.
Alteration in plasma free amino acid levels and its association with gout.
Mahbub, M H; Yamaguchi, Natsu; Takahashi, Hidekazu; Hase, Ryosuke; Amano, Hiroki; Kobayashi-Miura, Mikiko; Kanda, Hideyuki; Fujita, Yasuyuki; Yamamoto, Hiroshi; Yamamoto, Mai; Kikuchi, Shinya; Ikeda, Atsuko; Kageyama, Naoko; Nakamura, Mina; Ishimaru, Yasutaka; Sunagawa, Hiroshi; Tanabe, Tsuyoshi
2017-03-16
Studies on the association of plasma-free amino acids with gout are very limited and produced conflicting results. Therefore, we sought to explore and characterize the plasma-free amino acid (PFAA) profile in patients with gout and evaluate its association with the latter. Data from a total of 819 subjects (including 34 patients with gout) undergoing an annual health examination program in Shimane, Japan were considered for this study. Venous blood samples were collected from the subjects and concentrations of 19 plasma amino acids were determined by high-performance liquid chromatography-electrospray ionization-mass spectrometry. Student's t-test was applied for comparison of variables between patient and control groups. The relationships between the presence or absence of gout and individual amino acids were investigated by logistic regression analysis controlling for the effects of potential demographic confounders. Among 19 amino acids, the levels of 10 amino acids (alanine, glycine, isoleucine, leucine, methionine, phenylalanine, proline, serine, tryptophan, valine) differed significantly (P < .001 to .05) between the patient and control groups. Univariate logistic regression analysis revealed that plasma levels of alanine, isoleucine, leucine, phenylalanine, tryptophan and valine had significant positive associations (P < .005 to .05) whereas glycine and serine had significant inverse association (P < .05) with gout. The observed significant changes in PFAA profiles may have important implications for improving our understanding of pathophysiology, diagnosis and prevention of gout. The findings of this study need further confirmation in future large-scale studies involving a larger number of patients with gout.
Diagnosis of Sepsis with Cell-free DNA by Next-Generation Sequencing Technology in ICU Patients.
Long, Yun; Zhang, Yinxin; Gong, Yanping; Sun, Ruixue; Su, Longxiang; Lin, Xin; Shen, Ao; Zhou, Jiali; Caiji, Zhuoma; Wang, Xinying; Li, Dongfang; Wu, Honglong; Tan, Hongdong
2016-07-01
Bacteremia is a common serious manifestation of disease in the intensive care unit (ICU), which requires quick and accurate determinations of pathogens to select the appropriate antibiotic treatment. To overcome the shortcomings of traditional bacterial culture (BC), we have adapted next-generation sequencing (NGS) technology to identify pathogens from cell-free plasma DNA. In this study, 78 plasma samples from ICU patients were analyzed by both NGS and BC methods and verified by PCR amplification/Sanger sequencing and ten plasma samples from healthy volunteers were analyzed by NGS as negative controls to define or calibrate the threshold of the NGS methodology. Overall, 1578 suspected patient samples were found to contain bacteria or fungi by NGS, whereas ten patients were diagnosed by BC. Seven samples were diagnosed with bacterial or fungal infection both by NGS and BC. Among them, two samples were diagnosed with two types of bacteria by NGS, whereas one sample was diagnosed with two types of bacteria by BC, which increased the detectability of bacteria or fungi from 11 with BC to 17 with NGS. Most interestingly, 14 specimens were also diagnosed with viral infection by NGS. The overall diagnostic sensitivity was significantly increased from 12.82% (10/78) by BC alone to 30.77% (24/78) by NGS alone for ICU patients, which provides more useful information for establishing patient treatment plans. NGS technology can be applied to detect bacteria in clinical blood samples as an emerging diagnostic tool rich in information to determine the appropriate treatment of septic patients. Copyright © 2016 IMSS. Published by Elsevier Inc. All rights reserved.
Initial operation of the NSTX-Upgrade real-time velocity diagnostic
Podestà, M.; Bell, R. E.
2016-11-03
A real-time velocity (RTV) diagnostic based on active charge-exchange recombination spectroscopy is now operational on the National Spherical Torus Experiment-Upgrade (NSTX-U) spherical torus (Menard et al 2012 Nucl. Fusion 52 083015). We designed the system in order to supply plasma velocity data in real time to the NSTX-U plasma control system, as required for the implementation of toroidal rotation control. Our measurements are available from four radii at a maximum sampling frequency of 5 kHz. Post-discharge analysis of RTV data provides additional information on ion temperature, toroidal velocity and density of carbon impurities. Furthermore, examples of physics studies enabled bymore » RTV measurements from initial operations of NSTX-U are discussed.« less
Carey, Roger Neill; Jani, Chinu; Johnson, Curtis; Pearce, Jim; Hui-Ng, Patricia; Lacson, Eduardo
2016-09-07
Plasma samples collected in tubes containing separator gels have replaced serum samples for most chemistry tests in many hospital and commercial laboratories. Use of plasma samples for blood tests in the dialysis population eliminates delays in sample processing while waiting for clotting to complete, laboratory technical issues associated with fibrin formation, repeat sample collection, and patient care issues caused by delay of results because of incompletely clotted specimens. Additionally, a larger volume of plasma is produced than serum for the same amount of blood collected. Plasma samples are also acceptable for most chemical tests involved in the care of patients with ESRD. This information becomes very important when United States regulatory requirements for ESRD inadvertently limit the type of sample that can be used for government reporting, quality assessment, and value-based payment initiatives. In this narrative, we summarize the renal community experience and how the subsequent resolution of the acceptability of phosphorus levels measured from serum and plasma samples may have significant implications in the country's continued development of a value-based Medicare ESRD Quality Incentive Program. Copyright © 2016 by the American Society of Nephrology.
Synthesis and Characterization of Novel Compound Clusters
1997-08-26
also be intrinsically stable, they cannot be formed by this plasma chemistry presumably because the metals are less reactive. Plasma chemistry reactions...samples without the presence of hydrogen. Vaporization of these composite samples produces the metal carbide clusters in many cases where plasma chemistry does...antimony or bismuth cannot be produced by the hydrocarbon plasma chemistry method, but they are produced readily from composite sample (metal film on
Pochechueva, Tatiana; Alam, Shahidul; Schötzau, Andreas; Chinarev, Alexander; Bovin, Nicolai V; Hacker, Neville F; Jacob, Francis; Heinzelmann-Schwarz, Viola
2017-02-10
Glycosphingolipids are important compounds of the plasma membrane of mammalian cells and a number of them have been associated with malignant transformation and progression, reinforcing tumour aggressiveness and metastasis. Here we investigated the levels of naturally occurring anti-glycan antibodies to Globo H in blood plasma obtained from high-grade serous ovarian cancer patients (SOC) and women without gynaecological malignancies (control) using suspension glycan array technology employing chemically synthesized glycans as antibody targets. We found that anti-human Globo H IgG antibodies were able to significantly discriminate SOC from controls (P < 0.05). A combination with the clinically used tumour marker CA125 increased the diagnostic performance (AUC 0.8711). We next compared suspension array with standard flow cytometry in plasma samples and found that the level of anti-Globo H antibodies highly correlated (r = 0.992). The incubation of plasma-derived anti-glycan antibodies with chemically synthesized (presented on fluorescence microspheres) and native Globo H (expressed on Globo H-positive cell lines) revealed strong reactivity of naturally occurring human anti-Globo H antibodies towards its antigen expressed on ovarian cancer cells. Our data demonstrate that human plasma-derived antibodies to Globo H as well as the presence of the antigen might be considered as therapeutic option in ovarian cancer.
Comparison of the effects of acute and chronic psychological stress on metabolic features in rats*
Rostamkhani, Fatemeh; Zardooz, Homeira; Zahediasl, Saleh; Farrokhi, Babak
2012-01-01
This study was aimed to compare the effects of acute and chronic psychological stress on metabolic factors. Forty-two male Wistar rats were divided into control and stressed groups. Stress was applied by a communication box acutely (1 d) and chronically (15 and 30 d). Blood sampling was carried out by retro-orbital-puncture method. The plasma levels of glucose, cholesterol, triglyceride, insulin, and corticosterone were measured. In addition, feed and water intake, latency to eat and drink, adrenal and body weights were determined. Acute and chronic psychological stress did not significantly change basal plasma corticosterone levels. However, immediately (1 min) after acute exposure to stress, plasma corticosterone level increased compared to that before stress exposure. Acute stress increased plasma insulin levels significantly. Fifteen days of stress exposure resulted in plasma glucose increase. Chronic stress significantly increased feed intake, latency to eat, and adrenal weight compared to acute stress. The body weights of both control and stressed groups increased markedly during the experiment. Homeostasis model assessment of insulin resistance (HOMA-IR) index did not change significantly in the stressed group. In conclusion, application of acute and chronic psychological stress leads to different metabolic and/or behavioral changes but the metabolic changes resulting from acute exposure to stress seem to be more pronounced. PMID:23125083
Phomvisith, Ouanh; Takahashi, Hideyuki; Mai, Ha Thi; Shiotsuka, Yuji; Matsubara, Atsuko; Sugino, Toshihisa; Mcmahon, Christopher D; Etoh, Tetsuji; Fujino, Ryoichi; Furuse, Mitsuhiro; Gotoh, Takafumi
2017-04-01
We aimed to determine the effects of nutritional status on concentrations of somatotropic axis hormones (growth hormone (GH) and insulin-like growth factor 1 (IGF-1)), insulin and metabolites (glucose, total protein and nonesterified fatty acids (NEFA)) in the plasma and colostrum in late antepartum cows. Eight pregnant Japanese Black cows were randomly assigned to two experimental groups (n = 4 per group). Control cows (CON) received 100% of their nutritional requirements until parturition, whereas restricted group cows (RES) received 60% of their nutritional requirements. Blood samples were taken during the antepartum period, and blood and colostrum samples were collected on days 0, 1, and 3 after calving. Compared to the CON group, the RES group had higher concentrations of GH and NEFA in plasma, but significantly lower concentrations of glucose and insulin in plasma. The concentrations of GH in plasma after calving were significantly higher, but total plasma protein was significantly lower in RES than in CON cows. Compared to the CON group, the RES group had significantly higher concentrations of GH in colostrum, but significantly lower total concentrations of protein in colostrum. Concentrations of IGF-1 were not different between the two groups. These findings suggest that maternal nutritional status during late gestation influences concentrations of GH and total protein in the blood and colostrum of Japanese Black cows. © 2016 Japanese Society of Animal Science.
Prymont-Przyminska, Anna; Zwolinska, Anna; Sarniak, Agata; Wlodarczyk, Anna; Krol, Maciej; Nowak, Michal; de Graft-Johnson, Jeffrey; Padula, Gianluca; Bialasiewicz, Piotr; Markowski, Jaroslaw; Rutkowski, Krzysztof P.; Nowak, Dariusz
2014-01-01
Strawberries contain anthocyanins and ellagitanins which have antioxidant properties. We determined whether the consumption of strawberries increase the plasma antioxidant activity measured as the ability to decompose 2,2-diphenyl-1-picrylhydrazyl radical (DPPH) in healthy subjects. The study involved 10 volunteers (age 41 ± 6 years, body weight 74.4 ± 12.7 kg) that consumed 500 g of strawberries daily for 9 days and 7 matched controls. Fasting plasma and spot morning urine samples were collected at baseline, during fruit consumption and after a 6 day wash-out period. DPPH decomposition was measured in both deproteinized native plasma specimens and pretreated with uricase (non-urate plasma). Twelve phenolics were determined with HPLC. Strawberries had no effect on the antioxidant activity of native plasma and circulating phenolics. Non-urate plasma DPPH decomposition increased from 5.7 ± 0.6% to 6.6 ± 0.6%, 6.5 ± 1.0% and 6.3 ± 1.4% after 3, 6 and 9 days of supplementation, respectively. The wash-out period reversed this activity back to 5.7 ± 0.8% (p<0.01). Control subjects did not reveal any changes of plasma antioxidant activity. Significant increase in urinary urolithin A and 4-hydroxyhippuric (by 8.7- and 5.9-times after 6 days of supplementation with fruits) was noted. Strawberry consumption can increase the non-urate plasma antioxidant activity which, in turn, may decrease the risk of systemic oxidants overactivity. PMID:25120279
Fundamental and Applied Investigations in Atomic Spectrometric Analysis
NASA Astrophysics Data System (ADS)
Wu, Min
Simultaneous laser-excited fluorescence and absorption measurements were performed and the results have revealed that any interference caused by easily ionized elements does not originate from variations in analyte emission (quantum) efficiency. A closely related area, the roles of wet and dry aerosols in the matrix interference are clarified through spatially resolved imaging of the plasma by a charged coupled device camera. To eliminate matrix interference effects practically, various methods have been developed based on the above studies. The use of column pre-concentration with flow injection analysis has been found to provide a simple solution for reducing interference effects and increasing sensitivity of elemental analysis. A novel mini-spray chamber was invented. The new vertical rotary spray chamber combines gravitational, centrifugal, turbulent, and impact droplet segregation mechanisms to achieve a higher efficiency of small-droplet formation in a nebulized sample spray. As a result, it offers also higher sample-transport efficiency, lower memory effects, and improved analytical figures of merit over existing devices. This new device was employed with flow injection analysis to simulate an interface for coupling high performance liquid chromatography (HPLC) to a microwave plasma for chromatographic detection. The detection limits for common metallic elements are in the range of 5-50 mug/mL, and are degraded only twofold when the elements are presented in an organic solvent such as ethanol or methanol. Other sample-introduction schemes have also been investigated to improve sample-introduction technology. The direct coupling of hydride-generation techniques to the helium microwave plasma torch was evaluated for the determination of arsenic, antimony and tin by atomic emission spectrometry. A manually controlled peristaltic pump was modified for computer control and continuous flow injection was evaluated for standard calibration and trace elemental analysis. The present work evaluates the coupling of a novel microwave plasma torch with a quadruple mass spectrometer for the detection of ionic species from different nonmetals. Initial work performed with such a combination is demonstrated to be not only practicable but also promising. Detection limits for the halogens (F, Cl, Br, I) and S are in the range between 10 ng/mL and 1mug/mL. Further improvements have been realized through the use of chemical -vapor generation and by optimization of the plasma and the mass spectrometer. (Abstract shortened by UMI.).
Milman, Garry; Schwope, David M.; Schwilke, Eugene W.; Darwin, William D.; Kelly, Deanna L.; Goodwin, Robert S.; Gorelick, David A.; Huestis, Marilyn A.
2013-01-01
BACKGROUND Oral fluid (OF) testing is increasingly important for drug treatment, workplace, and drugged-driving programs. There is interest in predicting plasma or whole-blood concentrations from OF concentrations; however, the relationship between these matrices is incompletely characterized because of few controlled drug-administration studies. METHODS Ten male daily cannabis smokers received around-the-clock escalating 20-mg oral Δ9-tetrahydrocannabinol (THC, dronabinol) doses (40–120 mg/day) for 8 days. Plasma and OF samples were simultaneously collected before, during, and after dosing. OF THC, 11-hydroxy-THC and 11-nor-9-carboxy-THC (THCCOOH) were quantified by GC-MS at 0.5-μg/L, 0.5-μg/L, and 7.5-ng/L limits of quantification (LOQs), respectively. In plasma, the LOQs were 0.25 μg/L for THC and THCCOOH, and 0.5 μg/L for 11-hydroxy-THC. RESULTS Despite multiple oral THC administrations each day and increasing plasma THC concentrations, OF THC concentrations generally decreased over time, reflecting primarily previously self-administered smoked cannabis. The logarithms of the THC concentrations in oral fluid and plasma were not significantly correlated (r = −0.10; P = 0.065). The OF and plasma THCCOOH concentrations, albeit with 1000-fold higher concentrations in plasma, increased throughout dosing. The logarithms of OF and plasma THCCOOH concentrations were significantly correlated (r = 0.63; P < 0.001), although there was high interindividual variation. A high OF/plasma THC ratio and a high OF THC/THCCOOH ratio indicated recent cannabis smoking. CONCLUSIONS OF monitoring does not reliably detect oral dronabinol intake. The time courses of THC and THCCOOH concentrations in plasma and OF were different after repeated oral THC doses, and high inter-individual variation was observed. For these reasons, OF cannabinoid concentrations cannot predict concurrent plasma concentrations. PMID:21875944
NASA Astrophysics Data System (ADS)
Galiová, M.; Kaiser, J.; Novotný, K.; Novotný, J.; Vaculovič, T.; Liška, M.; Malina, R.; Stejskal, K.; Adam, V.; Kizek, R.
2008-12-01
Single-pulse Laser-Induced Breakdown Spectroscopy (LIBS) and Laser-Ablation Inductively Coupled Plasma Mass-Spectrometry (LA-ICP-MS) were applied for mapping the silver and copper distribution in Helianthus Annuus L. samples treated with contaminant in controlled conditions. For Ag and Cu detection the 328.07 nm Ag(I) and 324.75 nm Cu(I) lines were used, respectively. The LIBS experimental conditions (mainly the laser energy and the observation window) were optimized in order to avoid self-absorption effect in the measured spectra. In the LA-ICP-MS analysis the Ag 107 and Cu 63 isotopes were detected. The capability of these two analytical techniques for high-resolution mapping of selected trace chemical elements was demonstrated.
Irisin and the Metabolic Phenotype of Adults with Prader-Willi Syndrome.
Hirsch, Harry J; Gross, Itai; Pollak, Yehuda; Eldar-Geva, Talia; Gross-Tsur, Varda
2015-01-01
Hyperphagia, low resting energy expenditure, and abnormal body composition contribute to severe obesity in Prader Willi syndrome (PWS). Irisin, a circulating myokine, stimulates "browning" of white adipose tissue resulting in increased energy expenditure and improved insulin sensitivity. Irisin has not been previously studied in PWS. Compare plasma and salivary irisin in PWS adults and normal controls. Examine the relationship of irisin to insulin sensitivity and plasma lipids. A fasting blood sample for glucose, lipids, insulin, leptin, adinopectin, and irisin was obtained from 22 PWS adults and 54 healthy BMI-matched volunteers. Saliva was collected for irisin assay in PWS and controls. Fasting glucose (77 ± 9 vs 83 ± 7 mg/dl, p = 0.004), insulin (4.1 ± 2.0 vs 7.9 ± 4.7 μU/ml, p<0.001), and triglycerides (74 ± 34 vs 109 ± 71 mg/dl, p = 0.007) were lower in PWS than in controls. Insulin resistance (HOMA-IR) was lower (0.79 ± 0.041 vs 1.63 ± 1.02, p<0.001) and insulin sensitivity (QUICKI) was higher (0.41 ± 0.04 vs 0.36 ± 0.03, p<0.001) in PWS. Plasma irisin was similar in both groups, but salivary irisin (64.5 ± 52.0 vs 33.0 ± 12.1ng/ml), plasma leptin (33.5 ± 24.2 vs 19.7 ± 19.3 ng/ml) and plasma adinopectin (13.0 ± 10.8 vs 7.6 ± 4.5μg/ml) were significantly greater in PWS (p<0.001). In PWS, plasma irisin showed positive Pearson correlations with total cholesterol (r = 0.58, p = 0.005), LDL-cholesterol (r = 0.59, p = 0.004), and leptin (r = 0.43, p = 0.045). Salivary irisin correlated negatively with HDL-cholesterol (r = -0.50, p = 0.043) and positively with LDL-cholesterol (r = 0.51, p = 0.037) and triglycerides (r = 0.50, p = 0.041). Salivary irisin was markedly elevated in PWS although plasma irisin was similar to levels in controls. Significant associations with plasma lipids suggest that irisin may contribute to the metabolic phenotype of PWS.
Ikawa, K; Shimatani, T; Azuma, Y; Inoue, M; Morikawa, N
2006-08-01
To examine the effects of the histamine H(2)-receptor antagonist, lafutidine, at clinical dosage (10 mg tablet after a standardized meal) on plasma levels of the gastrointestinal peptides, calcitonin gene-related peptide (CGRP), somatostatin and gastrin. Six healthy male volunteers ate a standardized meal, and received either lafutidine orally at a dose of 10 mg or water only (control). Blood samples were taken before and up to 4 h after the drug administration. Plasma lafutidine concentrations were determined by high pressure liquid chromatography. Pharmacokinetic analysis of lafutidine was performed using one-compartmental model. The levels of immunoreactive substances of plasma CGRP, somatostatin and gastrin were measured by enzyme immunoassay, and the amount of peptide release was calculated by the trapezoidal method. Lafutidine significantly increased plasma CGRP levels at 1, 1.5, 2.5 and 4 h and the total amount of CGRP release (192 +/- 14.0 pg.h/mL) compared with the control group (128 +/- 21.5 pg.h/mL). Lafutidine significantly increased the plasma somatostatin levels at 1 and 1.5 h, and the total amount of somatostatin released (107 +/- 18.2 pg.h/mL) compared with the control (78.4 +/- 7.70 pg.h/mL). The area under the drug concentration-time curve (AUC) from 0 to 4 h after administration correlated well with the Delta-CGRP and Delta-somatostatin release but not with total amount of gastrin released. However, plasma gastrin levels were significantly elevated at 1.5 h after drug administration. Lafutidine at clinical dosage increases plasma CGRP and the somatostatin. The amounts released correlated with the AUC of lafutidine in humans. These results suggest that the increased release of CGRP and somatostatin may contribute to its gastroprotective and anti-acid secretory effect.
Wang, H; Weng, C; Chen, H
2017-07-01
Variants in G protein-coupled inward rectifier K + channels 4 (GIRK4 also known as KCNJ5) gene are associated with primary aldosteronism, which is the most common cause of secondary hypertension. The KCNJ5 rs2604204 variant was shown to be common (minor allele frequency=32.5%) in Chinese patients with essential hypertension (EH). The relationship between KCNJ5 variant and plasma aldosterone (ALD) levels in EH patients has not been reported. We collected 229 patients with newly diagnosed EH without any antihypertensive agents. According to the median standing plasma ALD, high-ALD and control groups were divided. Clinical data and blood samples were collected. KCNJ5 rs2604204 genotype was determined by PCR. The results showed that the levels of triglyceride, uric acid, insulin, insulin resistance (IR) index, renin, angiotensin I (Ang I), angiotensin II (Ang II), cortisol, 24 h mean systolic blood pressure (SBP) and daytime mean SBP were significantly increased in the high-ALD group than those in the control group, as well as 24 h s.d. of SBP and diastolic BP (DBP), and 24 h coefficient of variance of SBP and DBP. Notably, the distribution frequency of AC and CC genotypes, and the C allele of KCNJ5 were also significantly higher in the high-ALD group. Logistic regression analysis showed that the C allele of KCNJ5 rs2604204 was one risk factor for increased plasma ALD in Chinese EH patients (P=0.008, odds ratio=2.2 (95% confidence interval 1.2-4.1)). Our findings indicated that the variation of plasma ALD might be associated with increased IR and BP variability. Moreover, KCNJ5 rs2604204 polymorphism was related to increased plasma ALD level, but also plasma renin, Ang I and II levels in newly diagnosed, never-treated EH patients.
Brain-Derived Neurotrophic Factor in Patients with Huntington's Disease
Zuccato, Chiara; Mariotti, Caterina; Valenza, Marta; Lahiri, Nayana; Wild, Edward J.; Sassone, Jenny; Ciammola, Andrea; Bachoud-Lèvi, Anne Catherine; Tabrizi, Sarah J.; Di Donato, Stefano; Cattaneo, Elena
2011-01-01
Reduced Brain-Derived Neurotrophic Factor (BDNF) levels have been described in a number of patho-physiological conditions, most notably, in Huntington's disease (HD), a progressive neurodegenerative disorder. Since BDNF is also produced in blood, we have undertaken the measurement of its peripheral levels in the attempt to identify a possible link with HD prognosis and/or its progression. Here we evaluated BDNF level in 398 blood samples including 138 controls, 56 preHD, and 204 HD subjects. We found that BDNF protein levels were not reliably different between groups, whether measured in plasma (52 controls, 26 preHD, 105 HD) or serum (39 controls, 5 preHD, 29 HD). Our experience, and a re-analysis of the literature highlighted that intra-group variability and methodological aspects affect this measurement, especially in serum. We also assessed BDNF mRNA levels in blood samples from 47 controls, 25 preHD, and 70 HD subjects, and found no differences among the groups. We concluded that levels of BDNF in human blood were not informative (mRNA levels or plasma protein level) nor reliable (serum protein levels) as HD biomarkers. We also wish to warn the scientific community in interpreting the significance of changes measured in BDNF protein levels in serum from patients suffering from different conditions. PMID:21857974
NASA Astrophysics Data System (ADS)
Sakhnovskiy, M. Y.; Ushenko, V. A.
2013-09-01
The process of converting of laser radiation by optically anisotropic crystals of biological networks are singular in the sense of total (simultaneous) of mechanisms of orientation and phase (birefringence) anisotropy the formation of polarization-inhomogeneous field of scattered radiation. This work is aimed at developing a method of polarization selection mechanisms of blood plasma polycrystalline networks anisotropy. The relationship between statistics, correlation and fractal parameters of polarization-inhomogeneous images of blood plasma and by linear dichroism and linear birefringence of polycrystalline networks albumin and globulin was found. The criteria of differentiation and diagnostic images of polarization-inhomogeneous plasma samples of the control group (donor) and a group of patients with malignant changes of breast tissue was identified.
O'Neal, Wanda K; Anderson, Wayne; Basta, Patricia V; Carretta, Elizabeth E; Doerschuk, Claire M; Barr, R Graham; Bleecker, Eugene R; Christenson, Stephanie A; Curtis, Jeffrey L; Han, Meilan K; Hansel, Nadia N; Kanner, Richard E; Kleerup, Eric C; Martinez, Fernando J; Miller, Bruce E; Peters, Stephen P; Rennard, Stephen I; Scholand, Mary Beth; Tal-Singer, Ruth; Woodruff, Prescott G; Couper, David J; Davis, Sonia M
2014-01-08
As a part of the longitudinal Chronic Obstructive Pulmonary Disease (COPD) study, Subpopulations and Intermediate Outcome Measures in COPD study (SPIROMICS), blood samples are being collected from 3200 subjects with the goal of identifying blood biomarkers for sub-phenotyping patients and predicting disease progression. To determine the most reliable sample type for measuring specific blood analytes in the cohort, a pilot study was performed from a subset of 24 subjects comparing serum, Ethylenediaminetetraacetic acid (EDTA) plasma, and EDTA plasma with proteinase inhibitors (P100). 105 analytes, chosen for potential relevance to COPD, arranged in 12 multiplex and one simplex platform (Myriad-RBM) were evaluated in duplicate from the three sample types from 24 subjects. The reliability coefficient and the coefficient of variation (CV) were calculated. The performance of each analyte and mean analyte levels were evaluated across sample types. 20% of analytes were not consistently detectable in any sample type. Higher reliability and/or smaller CV were determined for 12 analytes in EDTA plasma compared to serum, and for 11 analytes in serum compared to EDTA plasma. While reliability measures were similar for EDTA plasma and P100 plasma for a majority of analytes, CV was modestly increased in P100 plasma for eight analytes. Each analyte within a multiplex produced independent measurement characteristics, complicating selection of sample type for individual multiplexes. There were notable detectability and measurability differences between serum and plasma. Multiplexing may not be ideal if large reliability differences exist across analytes measured within the multiplex, especially if values differ based on sample type. For some analytes, the large CV should be considered during experimental design, and the use of duplicate and/or triplicate samples may be necessary. These results should prove useful for studies evaluating selection of samples for evaluation of potential blood biomarkers.
2014-01-01
Background As a part of the longitudinal Chronic Obstructive Pulmonary Disease (COPD) study, Subpopulations and Intermediate Outcome Measures in COPD study (SPIROMICS), blood samples are being collected from 3200 subjects with the goal of identifying blood biomarkers for sub-phenotyping patients and predicting disease progression. To determine the most reliable sample type for measuring specific blood analytes in the cohort, a pilot study was performed from a subset of 24 subjects comparing serum, Ethylenediaminetetraacetic acid (EDTA) plasma, and EDTA plasma with proteinase inhibitors (P100™). Methods 105 analytes, chosen for potential relevance to COPD, arranged in 12 multiplex and one simplex platform (Myriad-RBM) were evaluated in duplicate from the three sample types from 24 subjects. The reliability coefficient and the coefficient of variation (CV) were calculated. The performance of each analyte and mean analyte levels were evaluated across sample types. Results 20% of analytes were not consistently detectable in any sample type. Higher reliability and/or smaller CV were determined for 12 analytes in EDTA plasma compared to serum, and for 11 analytes in serum compared to EDTA plasma. While reliability measures were similar for EDTA plasma and P100 plasma for a majority of analytes, CV was modestly increased in P100 plasma for eight analytes. Each analyte within a multiplex produced independent measurement characteristics, complicating selection of sample type for individual multiplexes. Conclusions There were notable detectability and measurability differences between serum and plasma. Multiplexing may not be ideal if large reliability differences exist across analytes measured within the multiplex, especially if values differ based on sample type. For some analytes, the large CV should be considered during experimental design, and the use of duplicate and/or triplicate samples may be necessary. These results should prove useful for studies evaluating selection of samples for evaluation of potential blood biomarkers. PMID:24397870
Xue, Lu; Lin, Lin; Zhou, Wenbin; Chen, Wendong; Tang, Jun; Sun, Xiujie; Huang, Peiwu; Tian, Ruijun
2018-06-09
Plasma proteome profiling by LC-MS based proteomics has drawn great attention recently for biomarker discovery from blood liquid biopsy. Due to standard multi-step sample preparation could potentially cause plasma protein degradation and analysis variation, integrated proteomics sample preparation technologies became promising solution towards this end. Here, we developed a fully integrated proteomics sample preparation technology for both fast and deep plasma proteome profiling under its native pH. All the sample preparation steps, including protein digestion and two-dimensional fractionation by both mixed-mode ion exchange and high-pH reversed phase mechanism were integrated into one spintip device for the first time. The mixed-mode ion exchange beads design achieved the sample loading at neutral pH and protein digestion within 30 min. Potential sample loss and protein degradation by pH changing could be voided. 1 μL of plasma sample with depletion of high abundant proteins was processed by the developed technology with 12 equally distributed fractions and analyzed with 12 h of LC-MS gradient time, resulting in the identification of 862 proteins. The combination of the Mixed-mode-SISPROT and data-independent MS method achieved fast plasma proteome profiling in 2 h with high identification overlap and quantification precision for a proof-of-concept study of plasma samples from 5 healthy donors. We expect that the Mixed-mode-SISPROT become a generally applicable sample preparation technology for clinical oriented plasma proteome profiling. Copyright © 2018 Elsevier B.V. All rights reserved.
Thermometry of the system “heat-resistant sample - incident plasma stream”
NASA Astrophysics Data System (ADS)
Sargsyan, M. A.; Chinnov, V. F.; Kavyrshin, D. I.; Gadzhiev, M. Kh; Khromov, M. A.; Chistolinov, A. V.; Senchenko, V. N.
2017-11-01
To study the interacting system “heat-resistant sample - an incident plasma stream” a setup of synchronized measurement equipment was developed and tested that recorded the main parameters of such interaction. Heat resistance tests were carried out on the samples of MPG-6 grade isotropic graphite, and samples of pyrolytic graphite that were subjected to a long (60 … 100 s) exposure to nitrogen, argon and air plasma streams at atmospheric pressure. As plasma generators a series of plasma torches with a vortex stabilization of the stream and an expanding anode channels was used. The temperature and composition of the plasma in the jet and near the sample were determined using two AvaSpec2048 and AvaSpec3648 scanning optical spectrometers and the MS5402i spectrograph with the Andor matrix at its outlet. The surface temperature of the sample was determined in real time using three independent ways: two pyrometric systems - a high-speed micro-pyrometer FMP1001 and a two-position visualization of the heated sample by high-speed Motion Pro X3 and VS-FAST cameras, and the spectral analysis of the wide-range thermal radiation of the samples. The main method for determining the rate of material loss during the action of a plasma jet on it was to analyze a two-position synchronous visualization of the “jet-sample” system. When a crater was formed on the surface of the sample under the “dagger” effect of a plasma jet, a video recording system of the crater zone was used, backlit using the “laser knife” method.
Mukherjee, Somaditya; Jagadeeshaprasad, Mashanipalya G; Banerjee, Tanima; Ghosh, Sudip K; Biswas, Monodeep; Dutta, Santanu; Kulkarni, Mahesh J; Pattari, Sanjib; Bandyopadhyay, Arun
2014-01-01
Rheumatic fever in childhood is the most common cause of Mitral Stenosis in developing countries. The disease is characterized by damaged and deformed mitral valves predisposing them to scarring and narrowing (stenosis) that results in left atrial hypertrophy followed by heart failure. Presently, echocardiography is the main imaging technique used to diagnose Mitral Stenosis. Despite the high prevalence and increased morbidity, no biochemical indicators are available for prediction, diagnosis and management of the disease. Adopting a proteomic approach to study Rheumatic Mitral Stenosis may therefore throw some light in this direction. In our study, we undertook plasma proteomics of human subjects suffering from Rheumatic Mitral Stenosis (n = 6) and Control subjects (n = 6). Six plasma samples, three each from the control and patient groups were pooled and subjected to low abundance protein enrichment. Pooled plasma samples (crude and equalized) were then subjected to in-solution trypsin digestion separately. Digests were analyzed using nano LC-MS(E). Data was acquired with the Protein Lynx Global Server v2.5.2 software and searches made against reviewed Homo sapiens database (UniProtKB) for protein identification. Label-free protein quantification was performed in crude plasma only. A total of 130 proteins spanning 9-192 kDa were identified. Of these 83 proteins were common to both groups and 34 were differentially regulated. Functional annotation of overlapping and differential proteins revealed that more than 50% proteins are involved in inflammation and immune response. This was corroborated by findings from pathway analysis and histopathological studies on excised tissue sections of stenotic mitral valves. Verification of selected protein candidates by immunotechniques in crude plasma corroborated our findings from label-free protein quantification. We propose that this protein profile of blood plasma, or any of the individual proteins, could serve as a focal point for future mechanistic studies on Mitral Stenosis. In addition, some of the proteins associated with this disorder may be candidate biomarkers for disease diagnosis and prognosis. Our findings might help to enrich existing knowledge on the molecular mechanisms involved in Mitral Stenosis and improve the current diagnostic tools in the long run.
NASA Astrophysics Data System (ADS)
Trnovcevic, J.; Schneider, F.; Scherer, U. W.
2017-02-01
The production of nuclear energy and the application of other nuclear technologies produce large volumes of low- and intermediate-level radioactive wastes. To investigate a novel means of treating such wastes, plasma is investigated for its efficacy. Plasma treatment promises to simultaneously treat all waste types without any previous sorting or pre-treatment. Microwave-driven plasma torches have the advantage of high-energy efficiency and low-electrode wear. In small-scale experiments, several design variations of an open plasma oven were assembled in order to investigate constraints caused by the materials and oven geometry. The experimental set-up was modified several times in order to test the design characteristics and the variation of plasma-specific proprieties related to the radioactive waste treatment and in order to find a suitable solution with the minimum complexity that allows a representative reproducibility of the results obtained. A plasma torch controlled by a 2.45 GHz microwave signal of up to 200 W was used, employing air as the primary plasma gas with a flow rate of ∼2 L/min. Different organic and inorganic materials in different shapes and sizes were treated besides a standardized mixture resembling mixed wastes from nuclear plants. The results prove that the chosen microwave plasma torch is suitable for a combined combustion and melting of organic and in-organic materials. Investigation of the specimen size to be treated is influential in this process: the power is still too low to melt larger samples, but the temperature is sufficient to treat all kinds of material. When glass particles are added, materials melt together to form an amorphous substance, proving the possibility to vitrify material with this plasma torch. By optimization of the oven configuration, the time needed to combust 25 g of standard sample was reduced by ∼50%. Typical energy efficiencies were found in the range of 8-20% for melting of metal chipping, and ∼90% for melting of zinc powder.
Liu, Chang-Cai; Huang, Gui-Lan; Xi, Hai-Ling; Liu, Shi-Lei; Liu, Jing-Quan; Yu, Hui-Lan; Zhou, Shi-Kun; Liang, Long-Hui; Yuan, Ling
2016-11-15
This work describes a novel and sensitive non-isotope dilution method for simultaneous quantification of organophosphorus nerve agents (OPNAs) soman (GD) and VX adducts to butyrylcholinesterase (BChE), their aged methylphosphonic acid (MeP) adduct and unadducted BChE in plasma exposed to OPNA. OPNA-BChE adducts were isolated with an off-column procainamide-gel separation (PGS) from plasma, and then digested with pepsin into specific adducted FGES * AGAAS nonapeptide (NP) biomarkers. The resulting NPs were detected by UHPLC-MS/MS MRM. The off-column PGS method can capture over 90% of BChE, MeP-BChE, VX-BChE and GD-BChE from their respective plasma materials. One newly designed and easily synthesized phosphorylated BChE nonapeptide with one Gly-to-Ala mutation was successfully reported to serve as internal standard instead of traditional isotopically labeled BChE nonapeptide. The linear range of calibration curves were from 1.00-200ngmL -1 for VX-NP, 2.00-200ngmL -1 for GD-NP and MeP-NP (R 2 ≥0.995), and 3.00-200ngmL -1 for BChE NP (R 2 ≥0.990). The inter-day precision had relative standard deviation (%RSD) of <8.89%, and the accuracy ranged between 88.9-120%. The limit of detection was calculated to be 0.411, 0.750, 0.800 and 1.43ngmL -1 for VX-NP, GD-NP, MeP-NP and BChE NP, respectively. OPNA-exposed quality control plasma samples were characterized as part of method validation. Investigation of plasma samples unexposed to OPNA revealed no baseline values or interferences. Using the off-column PGS method combined with UHPLC-MS/MS, VX-NP and GD-NP adducts can be unambiguously detected with high confidence in 0.10ngmL -1 and 0.50ngmL -1 of exposed human plasma respectively, only requiring 0.1mL of plasma sample and taking about four hours without special sample preparation equipment. These improvements make it a simple, sensitive and robust PGS-UHPLC-MS/MS method, and this method will become an attractive alternative to immunomagnetic separation (IMS) method and a useful diagnostic tool for retrospective detection of OPNA exposure with high confidence. Furthermore, using the developed method, the adducted BChE levels from VX and GD-exposed (0.10-100ngmL -1 ) plasma samples were completely characterized, and the fact that VX being more active and specific to BChE than GD was re-confirmed. Copyright © 2016 Elsevier B.V. All rights reserved.
Cohen, Joshua D; Javed, Ammar A; Thoburn, Christopher; Wong, Fay; Tie, Jeanne; Gibbs, Peter; Schmidt, C Max; Yip-Schneider, Michele T; Allen, Peter J; Schattner, Mark; Brand, Randall E; Singhi, Aatur D; Petersen, Gloria M; Hong, Seung-Mo; Kim, Song Cheol; Falconi, Massimo; Doglioni, Claudio; Weiss, Matthew J; Ahuja, Nita; He, Jin; Makary, Martin A; Maitra, Anirban; Hanash, Samir M; Dal Molin, Marco; Wang, Yuxuan; Li, Lu; Ptak, Janine; Dobbyn, Lisa; Schaefer, Joy; Silliman, Natalie; Popoli, Maria; Goggins, Michael G; Hruban, Ralph H; Wolfgang, Christopher L; Klein, Alison P; Tomasetti, Cristian; Papadopoulos, Nickolas; Kinzler, Kenneth W; Vogelstein, Bert; Lennon, Anne Marie
2017-09-19
The earlier diagnosis of cancer is one of the keys to reducing cancer deaths in the future. Here we describe our efforts to develop a noninvasive blood test for the detection of pancreatic ductal adenocarcinoma. We combined blood tests for KRAS gene mutations with carefully thresholded protein biomarkers to determine whether the combination of these markers was superior to any single marker. The cohort tested included 221 patients with resectable pancreatic ductal adenocarcinomas and 182 control patients without known cancer. KRAS mutations were detected in the plasma of 66 patients (30%), and every mutation found in the plasma was identical to that subsequently found in the patient's primary tumor (100% concordance). The use of KRAS in conjunction with four thresholded protein biomarkers increased the sensitivity to 64%. Only one of the 182 plasma samples from the control cohort was positive for any of the DNA or protein biomarkers (99.5% specificity). This combinatorial approach may prove useful for the earlier detection of many cancer types.
Zhang, Qibin; Monroe, Matthew E.; Schepmoes, Athena A.; Clauss, Therese R. W.; Gritsenko, Marina A.; Meng, Da; Petyuk, Vladislav A.; Smith, Richard D.; Metz, Thomas O.
2011-01-01
Non-enzymatic glycation of proteins sets the stage for formation of advanced glycation end-products and development of chronic complications of diabetes. In this report, we extended our previous methods on proteomics analysis of glycated proteins to comprehensively identify glycated proteins in control and diabetic human plasma and erythrocytes. Using immunodepletion, enrichment, and fractionation strategies, we identified 7749 unique glycated peptides, corresponding to 3742 unique glycated proteins. Semi-quantitative comparisons showed that glycation levels of a number of proteins were significantly increased in diabetes and that erythrocyte proteins were more extensively glycated than plasma proteins. A glycation motif analysis revealed that some amino acids were favored more than others in the protein primary structures in the vicinity of the glycation sites in both sample types. The glycated peptides and corresponding proteins reported here provide a foundation for potential identification of novel markers for diabetes, hyperglycemia, and diabetic complications in future studies. PMID:21612289
Metabolic epidermal necrosis in two dogs with different underlying diseases.
Bond, R; McNeil, P E; Evans, H; Srebernik, N
1995-05-06
Two dogs with metabolic epidermal necrosis had hyperkeratosis of the footpads accompanied by erythematous, erosive and crusting lesions affecting the muzzle, external genitalia, perineum and periocular regions. Histopathological examination of skin biopsies revealed a superficial hydropic dermatitis with marked parakeratosis. Both dogs had high plasma activities of alkaline phosphatase and alanine aminotransferase and high concentrations of glucose, and also a marked hypoaminoacidaemia. Despite these similarities, the cutaneous eruptions were associated with different underlying diseases. One dog had a pancreatic carcinoma which had metastasised widely; the primary tumour and the metastases showed glucagon immunoreactivity on immunocytochemical staining, and the dog's plasma glucagon concentration was markedly greater than that of control dogs. The other dog had diffuse hepatic disease; its plasma glucagon concentration was similar to that of control samples and cirrhosis was identified post mortem. Metabolic epidermal necrosis in dogs is a distinct cutaneous reaction pattern which may be associated with different underlying systemic diseases; however, the pathogenesis of the skin lesions remains unclear.
Laresche, Claire; Pelletier, Fabien; Garnache-Ottou, Francine; Lihoreau, Thomas; Biichlé, Sabeha; Mourey, Guillaume; Saas, Philippe; Humbert, Philippe; Seilles, Estelle; Aubin, François
2014-01-01
Microparticles (MPs) are known to be increased in various malignancies and are involved in tumor invasion, angiogenesis, coagulation, and metastasis. We investigated the plasma levels of annexin-V MPs (AV(+)MPs), platelet-derived MPs (PMPs), and endothelial-derived MPs (EMPs) in patients with melanoma (n=129) and in healthy controls (n=49). A functional coagulation test STA Procoag-PPL measuring the clotting time was performed on samples containing MPs to evaluate their procoagulant potential. The plasma levels of PMPs, EMPs, and AV(+)MPs were significantly higher, and the clotting time-PPL was significantly lower in melanoma patients than in healthy controls. The plasma levels of PMPs, EMPs, and AV(+)MPs were higher in stage IV than in the other stages of melanoma, but with no significant difference. In addition, we observed an inverse correlation between PMPs, AV(+)MPs, and clotting times. Our data suggest that MPs are involved in the progression of melanoma and may be associated to melanoma-associated thrombogenesis.
Tittarelli, Roberta; Pichini, Simona; Pedersen, Daniel S; Pacifici, Roberta; Moresco, Monica; Pizza, Fabio; Busardò, Francesco Paolo; Plazzi, Giuseppe
2017-05-01
Sodium oxybate (Xyrem ® ), the sodium salt of γ- hydroxybutyric acid (GHB), is a first-line treatment of the symptoms induced by type 1 narcolepsy (NT1) and it is highly effective in improving sleep architecture, decreasing excessive daytime sleepiness and the frequency of cataplexy attacks. Using an ultra-high-performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) validated method, GHB was determined together with its glucuronide (GHB-gluc), in plasma and cerebrospinal fluid (CSF) samples of NT1 patients under sodium oxybate treatment. To characterize the plasma pharmacokinetics of GHB, three subjects with NT1 were administered at time 0 and 4h with 1.25, 1.5 and 3.55g Xyrem ® , respectively and had their blood samples collected at 7 time points throughout an 8-h session. CSF specimens, collected for orexin A measurement from the same three subjects 6h after their second administration, were also tested. The results obtained suggested that GHB plasma values increased disproportionally with the rising doses, (C max0-4 : 12.53, 32.95 and 69.62μg/mL; C max4-8 : 44.93, 75.03 and 111.93μg/mL for total Xyrem ® dose of 2.5, 3 and 7g respectively) indicating non-linear dose-response. GHB-Gluc was present only in traces in all plasma samples from treated patients, not changing with increasing Xyrem ® doses. GHB values of 5.62, 6.10 and 17.74μg/mL for 2, 3 and 7g Xyrem ® were found in CSF with a significant difference from control values. GHB-Gluc was found in negligible concentrations with no differences to those of control individuals. In conclusion this simple and fast UHPLC-MS/MS method proved useful for pharmacokinetic studies and therapeutic drug monitoring of GHB in narcoleptic patients treated with sodium oxybate. Copyright © 2017 Elsevier B.V. All rights reserved.
Urinary Phenylacetylglutamine as Dosing Biomarker for Patients with Urea Cycle Disorders
Mokhtarani, M; Diaz, GA; Rhead, W; Lichter-Konecki, U; Bartley, J; Feigenbaum, A; Longo, N; Berquist, W; Berry, SA; Gallagher, R; Bartholomew, D; Harding, CO; Korson, MS; McCandless, SE; Smith, W; Vockley, J; Bart, S; Kronn, D; Zori, R; Cederbaum, S; Dorrani, N; Merritt, JL; Sreenath-Nagamani, Sandesh; Summar, M; LeMons, C; Dickinson, K; Coakley, DF; Moors, TL; Lee, B; Scharschmidt, BF
2013-01-01
We have analyzed pharmacokinetic data for glycerol phenylbutyrate (also GT4P or HPN-100) and sodium phenylbutyrate with respect to possible dosing biomarkers in patients with urea cycle disorders (UCD). Study Design These analyses are based on over 3000 urine and plasma data points from 54 adult and 11 pediatric UCD patients (ages 6–17) who participated in three clinical studies comparing ammonia control and pharmacokinetics during steady state treatment with glycerol phenylbutyrate or sodium phenylbutyrate. All patients received phenylbutyric acid equivalent doses of glycerol phenylbutyrate or sodium phenylbutyrate in a cross over fashion and underwent 24-hour blood samples and urine sampling for phenylbutyric acid, phenylacetic acid and phenylacetylglutamine. Results Patients received phenylbutyric acid equivalent doses of glycerol phenylbutyrate ranging from 1.5–31.8 g/day and of sodium phenylbutyrate ranging from 1.3–31.7 g/day. Plasma metabolite levels varied widely, with average fluctuation indices ranging from 1979% –5690% for phenylbutyric acid, 843% to 3931% for phenylacetic acid, and 881% -to 1434% for phenylacetylglutamine. Mean percent recovery of phenylbutyric acid as urinary phenylacetylglutamine was 66.4 and 69.0 for pediatric patients and 68.7 and 71.4 for adult patients on glycerol phenylbutyrate and sodium phenylbutyrate, respectively. The correlation with dose was strongest for urinary phenylacetylglutamine excretion, either as morning spot urine (r=0.730, p<0.001) or as total 24-hour excretion (r=0.791 p<0.001), followed by plasma phenylacetylglutamine AUC24-hour, plasma phenylacetic acid AUC24-hour and phenylbutyric acid AUC24-hour. Plasma phenylacetic acid levels in adult and pediatric patients did not show a consistent relationship with either urinary phenylacetylglutamine or ammonia control. Conclusion The findings are collectively consistent with substantial yet variable pre-systemic (1st pass) conversion of phenylbutyric acid to phenylacetic acid and/or phenylacetylglutamine. The variability of blood metabolite levels during the day, their weaker correlation with dose, the need for multiple blood samples to capture trough and peak, and the inconsistency between phenylacetic acid and urinary phenylacetylglutamine as a marker of waste nitrogen scavenging limit the utility of plasma levels for therapeutic monitoring. By contrast, 24-hour urinary phenylacetylglutamine and morning spot urine phenylacetylglutamine correlate strongly with dose and appear to be clinically useful non-invasive biomarkers for compliance and therapeutic monitoring. PMID:22958974
Urinary phenylacetylglutamine as dosing biomarker for patients with urea cycle disorders.
Mokhtarani, M; Diaz, G A; Rhead, W; Lichter-Konecki, U; Bartley, J; Feigenbaum, A; Longo, N; Berquist, W; Berry, S A; Gallagher, R; Bartholomew, D; Harding, C O; Korson, M S; McCandless, S E; Smith, W; Vockley, J; Bart, S; Kronn, D; Zori, R; Cederbaum, S; Dorrani, N; Merritt, J L; Sreenath-Nagamani, Sandesh; Summar, M; Lemons, C; Dickinson, K; Coakley, D F; Moors, T L; Lee, B; Scharschmidt, B F
2012-11-01
We have analyzed pharmacokinetic data for glycerol phenylbutyrate (also GT4P or HPN-100) and sodium phenylbutyrate with respect to possible dosing biomarkers in patients with urea cycle disorders (UCD). These analyses are based on over 3000 urine and plasma data points from 54 adult and 11 pediatric UCD patients (ages 6-17) who participated in three clinical studies comparing ammonia control and pharmacokinetics during steady state treatment with glycerol phenylbutyrate or sodium phenylbutyrate. All patients received phenylbutyric acid equivalent doses of glycerol phenylbutyrate or sodium phenylbutyrate in a cross over fashion and underwent 24-hour blood samples and urine sampling for phenylbutyric acid, phenylacetic acid and phenylacetylglutamine. Patients received phenylbutyric acid equivalent doses of glycerol phenylbutyrate ranging from 1.5 to 31.8 g/day and of sodium phenylbutyrate ranging from 1.3 to 31.7 g/day. Plasma metabolite levels varied widely, with average fluctuation indices ranging from 1979% to 5690% for phenylbutyric acid, 843% to 3931% for phenylacetic acid, and 881% to 1434% for phenylacetylglutamine. Mean percent recovery of phenylbutyric acid as urinary phenylacetylglutamine was 66.4 and 69.0 for pediatric patients and 68.7 and 71.4 for adult patients on glycerol phenylbutyrate and sodium phenylbutyrate, respectively. The correlation with dose was strongest for urinary phenylacetylglutamine excretion, either as morning spot urine (r = 0.730, p < 0.001) or as total 24-hour excretion (r = 0.791 p<0.001), followed by plasma phenylacetylglutamine AUC(24-hour), plasma phenylacetic acid AUC(24-hour) and phenylbutyric acid AUC(24-hour). Plasma phenylacetic acid levels in adult and pediatric patients did not show a consistent relationship with either urinary phenylacetylglutamine or ammonia control. The findings are collectively consistent with substantial yet variable pre-systemic (1st pass) conversion of phenylbutyric acid to phenylacetic acid and/or phenylacetylglutamine. The variability of blood metabolite levels during the day, their weaker correlation with dose, the need for multiple blood samples to capture trough and peak, and the inconsistency between phenylacetic acid and urinary phenylacetylglutamine as a marker of waste nitrogen scavenging limit the utility of plasma levels for therapeutic monitoring. By contrast, 24-hour urinary phenylacetylglutamine and morning spot urine phenylacetylglutamine correlate strongly with dose and appear to be clinically useful non-invasive biomarkers for compliance and therapeutic monitoring. Copyright © 2012 Elsevier Inc. All rights reserved.
Pitteri, Sharon J.; Amon, Lynn M.; Buson, Tina Busald; Zhang, Yuzheng; Johnson, Melissa M.; Chin, Alice; Kennedy, Jacob; Wong, Chee-Hong; Zhang, Qing; Wang, Hong; Lampe, Paul D.; Prentice, Ross L.; McIntosh, Martin W.; Hanash, Samir M.; Li, Christopher I.
2010-01-01
Applying advanced proteomic technologies to prospectively collected specimens from large studies is one means of identifying preclinical changes in plasma proteins that are potentially relevant to the early detection of diseases like breast cancer. We conducted fourteen independent quantitative proteomics experiments comparing pooled plasma samples collected from 420 estrogen receptor positive (ER+) breast cancer patients ≤17 months prior to their diagnosis and matched controls. Based on the over 3.4 million tandem mass spectra collected in the discovery set, 503 proteins were quantified of which 57 differentiated cases from controls with a p-value<0.1. Seven of these proteins, for which quantitative ELISA assays were available, were assessed in an independent validation set. Of these candidates, epidermal growth factor receptor (EGFR) was validated as a predictor of breast cancer risk in an independent set of preclinical plasma samples for women overall [odds ratio (OR)=1.44, p-value=0.0008], and particularly for current users of estrogen plus progestin (E+P) menopausal hormone therapy (OR=2.49, p-value=0.0001). Among current E+P users EGFR's sensitivity for breast cancer risk was 31% with 90% specificity. While EGFR's sensitivity and specificity are insufficient for a clinically useful early detection biomarker, this study suggests that proteins that are elevated preclinically in women who go on to develop breast cancer can be discovered and validated using current proteomic technologies. Further studies are warranted to both examine the role of EGFR and to discover and validate other proteins that could potentially be used for breast cancer early detection. PMID:20959476
Rubenstein, Richard; Chang, Binggong; Yue, John K.; Chiu, Allen; Winkler, Ethan A.; Puccio, Ava M.; Diaz-Arrastia, Ramon; Yuh, Esther L.; Mukherjee, Pratik; Valadka, Alex B.; Gordon, Wayne A.; Okonkwo, David O.; Davies, Peter; Agarwal, Sanjeev; Lin, Fan; Sarkis, George; Yadikar, Hamad; Yang, Zhihui; Manley, Geoffrey T.; Wang, Kevin K. W.
2017-01-01
IMPORTANCE Annually in the United States, at least 3.5 million people seek medical attention for traumatic brain injury (TBI). The development of therapies for TBI is limited by the absence of diagnostic and prognostic biomarkers. Microtubule-associated protein tau is an axonal phosphoprotein. To date, the presence of the hypophosphorylated tau protein (P-tau) in plasma from patients with acute TBI and chronic TBI has not been investigated. OBJECTIVE To examine the associations between plasma P-tau and total-tau (T-tau) levels and injury presence, severity, type of pathoanatomic lesion (neuroimaging), and patient outcomes in acute and chronic TBI. DESIGN, SETTING, AND PARTICIPANTS In the TRACK-TBI Pilot study, plasma was collected at a single time point from 196 patients with acute TBI admitted to 3 level I trauma centers (<24 hours after injury) and 21 patients with TBI admitted to inpatient rehabilitation units (mean [SD], 176.4 [44.5] days after injury). Control samples were purchased from a commercial vendor. The TRACK-TBI Pilot study was conducted from April 1, 2010, to June 30, 2012. Data analysis for the current investigation was performed from August 1, 2015, to March 13, 2017. MAIN OUTCOMES AND MEASURES Plasma samples were assayed for P-tau (using an antibody that specifically recognizes phosphothreonine-231) and T-tau using ultra-high sensitivity laser-based immunoassay multi-arrayed fiberoptics conjugated with rolling circle amplification. RESULTS In the 217 patients with TBI, 161 (74.2%) were men; mean (SD) age was 42.5 (18.1) years. The P-tau and T-tau levels and P-tau–T-tau ratio in patients with acute TBI were higher than those in healthy controls. Receiver operating characteristic analysis for the 3 tau indices demonstrated accuracy with area under the curve (AUC) of 1.000, 0.916, and 1.000, respectively, for discriminating mild TBI (Glasgow Coma Scale [GCS] score, 13–15, n = 162) from healthy controls. The P-tau level and P-tau–T-tau ratio were higher in individuals with more severe TBI (GCS, ≤12 vs 13–15). The P-tau level and P-tau–T-tau ratio outperformed the T-tau level in distinguishing cranial computed tomography–positive from −negative cases (AUC = 0.921, 0.923, and 0.646, respectively). Acute P-tau levels and P-tau–T-tau ratio weakly distinguished patients with TBI who had good outcomes (Glasgow Outcome Scale–Extended GOS-E, 7–8) (AUC = 0.663 and 0.658, respectively) and identified those with poor outcomes (GOS-E, ≤4 vs >4) (AUC = 0.771 and 0.777, respectively). Plasma samples from patients with chronic TBI also showed elevated P-tau levels and a P-tau–T-tau ratio significantly higher than that of healthy controls, with both P-tau indices strongly discriminating patients with chronic TBI from healthy controls (AUC = 1.000 and 0.963, respectively). CONCLUSIONS AND RELEVANCE Plasma P-tau levels and P-tau–T-tau ratio outperformed T-tau level as diagnostic and prognostic biomarkers for acute TBI. Compared with T-tau levels alone, P-tau levels and P-tau–T-tau ratios show more robust and sustained elevations among patients with chronic TBI. PMID:28738126
Rubenstein, Richard; Chang, Binggong; Yue, John K; Chiu, Allen; Winkler, Ethan A; Puccio, Ava M; Diaz-Arrastia, Ramon; Yuh, Esther L; Mukherjee, Pratik; Valadka, Alex B; Gordon, Wayne A; Okonkwo, David O; Davies, Peter; Agarwal, Sanjeev; Lin, Fan; Sarkis, George; Yadikar, Hamad; Yang, Zhihui; Manley, Geoffrey T; Wang, Kevin K W; Cooper, Shelly R; Dams-O'Connor, Kristen; Borrasso, Allison J; Inoue, Tomoo; Maas, Andrew I R; Menon, David K; Schnyer, David M; Vassar, Mary J
2017-09-01
Annually in the United States, at least 3.5 million people seek medical attention for traumatic brain injury (TBI). The development of therapies for TBI is limited by the absence of diagnostic and prognostic biomarkers. Microtubule-associated protein tau is an axonal phosphoprotein. To date, the presence of the hypophosphorylated tau protein (P-tau) in plasma from patients with acute TBI and chronic TBI has not been investigated. To examine the associations between plasma P-tau and total-tau (T-tau) levels and injury presence, severity, type of pathoanatomic lesion (neuroimaging), and patient outcomes in acute and chronic TBI. In the TRACK-TBI Pilot study, plasma was collected at a single time point from 196 patients with acute TBI admitted to 3 level I trauma centers (<24 hours after injury) and 21 patients with TBI admitted to inpatient rehabilitation units (mean [SD], 176.4 [44.5] days after injury). Control samples were purchased from a commercial vendor. The TRACK-TBI Pilot study was conducted from April 1, 2010, to June 30, 2012. Data analysis for the current investigation was performed from August 1, 2015, to March 13, 2017. Plasma samples were assayed for P-tau (using an antibody that specifically recognizes phosphothreonine-231) and T-tau using ultra-high sensitivity laser-based immunoassay multi-arrayed fiberoptics conjugated with rolling circle amplification. In the 217 patients with TBI, 161 (74.2%) were men; mean (SD) age was 42.5 (18.1) years. The P-tau and T-tau levels and P-tau-T-tau ratio in patients with acute TBI were higher than those in healthy controls. Receiver operating characteristic analysis for the 3 tau indices demonstrated accuracy with area under the curve (AUC) of 1.000, 0.916, and 1.000, respectively, for discriminating mild TBI (Glasgow Coma Scale [GCS] score, 13-15, n = 162) from healthy controls. The P-tau level and P-tau-T-tau ratio were higher in individuals with more severe TBI (GCS, ≤12 vs 13-15). The P-tau level and P-tau-T-tau ratio outperformed the T-tau level in distinguishing cranial computed tomography-positive from -negative cases (AUC = 0.921, 0.923, and 0.646, respectively). Acute P-tau levels and P-tau-T-tau ratio weakly distinguished patients with TBI who had good outcomes (Glasgow Outcome Scale-Extended GOS-E, 7-8) (AUC = 0.663 and 0.658, respectively) and identified those with poor outcomes (GOS-E, ≤4 vs >4) (AUC = 0.771 and 0.777, respectively). Plasma samples from patients with chronic TBI also showed elevated P-tau levels and a P-tau-T-tau ratio significantly higher than that of healthy controls, with both P-tau indices strongly discriminating patients with chronic TBI from healthy controls (AUC = 1.000 and 0.963, respectively). Plasma P-tau levels and P-tau-T-tau ratio outperformed T-tau level as diagnostic and prognostic biomarkers for acute TBI. Compared with T-tau levels alone, P-tau levels and P-tau-T-tau ratios show more robust and sustained elevations among patients with chronic TBI.
Kannangai, R; Sachithanandham, J; Kandathil, A J; Ebenezer, D L; Danda, D; Vasuki, Z; Thomas, N; Vasan, S K; Sridharan, G
2010-01-01
Autoimmune diseases usually manifest in genetically predisposed individuals following an environmental trigger. There are several viral infections including Epstein-Barr virus (EBV) implicated in the pathogenesis of autoimmune disorders. The aim of this study was to look at the antibody pattern to EBV proteins in the plasma of both systemic and organ specific autoimmune disorders, estimate pro-inflammatory plasma cytokines (IL-8 and TNF-alpha) among these autoimmune patients and compare the observations with those in normal healthy controls. Samples from 44 rheumatoid arthritis patients, 25 Hashimoto's thyroiditis patients, appropriately age and sex matched healthy controls were tested for EBV IgM antibodies by an immunoblot assay and two cytokines (IL-8 and TNF-alpha) by commercial assays. Among the rheumatoid arthritis patients, 23 (52%) were positive for EBNA1 antibody, while 13 (52%) of the Hashimoto's thyroiditis patients and 12 (30%) of the healthy controls showed similar bands. The intensity of the bands was high in the autoimmune patients when compared to the bands seen in control samples. The difference in the EBNA1 reactivity between rheumatoid arthritis patients and controls were significant (P = 0.038). There was a significant difference in the IgM reactivity to VCAp19 protein between patients and controls (P = 0.011). Our study showed an increased EBV activation among the autoimmune patient groups compared to the normal healthy controls. Further studies are required to delineate the association between the aetiology of autoimmune disorders and EBV.
Carran, E L; White, S J; Reynolds, A N; Haszard, J J; Venn, B J
2016-09-01
Excessive fructose intake has been linked to hyperuricaemia. Our aim was to test whether 355 and 600 ml of commercial sugar-sweetened soft drinks would acutely raise plasma uric acid. Forty-one participants were randomised to a control group or an intervention group. The control group consumed 600 ml of fructose and 600 ml of glucose beverages. The soft drink group consumed 355 and 600 ml of beverages in random order. The control beverages were matched for fructose content with 600 ml of soft drink (26.7 g). Blood samples were collected at baseline, 30 and 60 min and analysed for plasma uric acid. Plasma uric acid concentrations were 13 (95% confidence interval: (CI): 3, 23) and 17 μmol/l (95% CI: 6, 28) higher 30 and 60 min after consumption of 600 ml of soft drink compared with the glucose control. The corresponding values for the fructose beverage were 22 (95% CI: 16, 29) and 23 μmol/l (95% CI: 14, 33). There was no significant difference in the increase in uric acid following the 600-ml soft drink compared with the fructose control at 30 min (6 μmol/l; 95% CI: -4, 15) or 60 min (5 μmol/l; 95% CI: -7, 17). There was no difference in the uric-acid-raising effect between the 355 and 600 ml volumes at 30 min (-1 μmol/l; 95% CI: -9, 6) or 60 min (-5 μmol/l; 95% CI: -10, 1). Small and transient increases in plasma uric acid are likely after consumption of sucrose-sweetened commercially available single-serve soft drinks in volumes as small as 355 ml.
Löscher, W; Fassbender, C P; Gram, L; Gramer, M; Hörstermann, D; Zahner, B; Stefan, H
1993-03-01
The novel antiepileptic drug vigabatrin (Sabril) acts by inhibiting degradation of the inhibitory neurotransmitter gamma-aminobutyric acid (GABA), increasing the GABA concentrations in the brain. Because the GABA degrading enzyme GABA aminotransferase (GABA-T) is also present in peripheral tissues, including blood platelets, measurement of plasma GABA levels might be a useful indication of the pharmacological response to vigabatrin during therapeutic monitoring. However, because of the very low concentrations of GABA in plasma, the few methods available for plasma GABA analysis are time-consuming, difficult to perform and/or not selective enough because of potential interference with other plasma constituents. In the present study, a rapid, selective and sensitive amino acid analysis HPLC method has been developed for plasma GABA determination with fluorescence detection, using o-phthaldialdehyde as a precolumn derivatizing agent. By employing a 3 microns particle size reversed-phase column and a multi-step gradient system of two solvents, the very low endogenous concentration of GABA in human plasma could be reproducibly quantitated without interference of other endogenous compounds. Incubation of human plasma samples with GABA degrading enzyme(s) resulted in an almost total loss of the GABA peak, thus demonstrating the specificity of the method for GABA analysis. In addition to GABA and other endogenous amino acids, the HPLC method could be used to quantitate plasma levels of vigabatrin. Thus, this improved HPLC amino acid assay might be used to examine whether concomitant monitoring of plasma GABA and vigabatrin is useful for clinical purposes. This was examined in 20 epileptic patients undergoing chronic treatment with vigabatrin. The average plasma GABA level of these 20 patients did not differ significantly from non-epileptic controls. However, when epileptic patients were subdivided according to their clinical response to vigabatrin, vigabatrin responders had significantly higher GABA levels than nonresponders or controls. In contrast to the difference in plasma GABA, vigabatrin responders and nonresponders did not differ in dose or plasma level of vigabatrin. These data may indicate that determination of plasma GABA is a valuable non-invasive method for therapeutic monitoring in patients on medication with vigabatrin.
Haab, Brian B; Huang, Ying; Balasenthil, Seetharaman; Partyka, Katie; Tang, Huiyuan; Anderson, Michelle; Allen, Peter; Sasson, Aaron; Zeh, Herbert; Kaul, Karen; Kletter, Doron; Ge, Shaokui; Bern, Marshall; Kwon, Richard; Blasutig, Ivan; Srivastava, Sudhir; Frazier, Marsha L; Sen, Subrata; Hollingsworth, Michael A; Rinaudo, Jo Ann; Killary, Ann M; Brand, Randall E
2015-01-01
The validation of candidate biomarkers often is hampered by the lack of a reliable means of assessing and comparing performance. We present here a reference set of serum and plasma samples to facilitate the validation of biomarkers for resectable pancreatic cancer. The reference set includes a large cohort of stage I-II pancreatic cancer patients, recruited from 5 different institutions, and relevant control groups. We characterized the performance of the current best serological biomarker for pancreatic cancer, CA 19-9, using plasma samples from the reference set to provide a benchmark for future biomarker studies and to further our knowledge of CA 19-9 in early-stage pancreatic cancer and the control groups. CA 19-9 distinguished pancreatic cancers from the healthy and chronic pancreatitis groups with an average sensitivity and specificity of 70-74%, similar to previous studies using all stages of pancreatic cancer. Chronic pancreatitis patients did not show CA 19-9 elevations, but patients with benign biliary obstruction had elevations nearly as high as the cancer patients. We gained additional information about the biomarker by comparing two distinct assays. The two CA 9-9 assays agreed well in overall performance but diverged in measurements of individual samples, potentially due to subtle differences in antibody specificity as revealed by glycan array analysis. Thus, the reference set promises be a valuable resource for biomarker validation and comparison, and the CA 19-9 data presented here will be useful for benchmarking and for exploring relationships to CA 19-9.
Haab, Brian B.; Huang, Ying; Balasenthil, Seetharaman; Partyka, Katie; Tang, Huiyuan; Anderson, Michelle; Allen, Peter; Sasson, Aaron; Zeh, Herbert; Kaul, Karen; Kletter, Doron; Ge, Shaokui; Bern, Marshall; Kwon, Richard; Blasutig, Ivan; Srivastava, Sudhir; Frazier, Marsha L.; Sen, Subrata; Hollingsworth, Michael A.; Rinaudo, Jo Ann; Killary, Ann M.; Brand, Randall E.
2015-01-01
The validation of candidate biomarkers often is hampered by the lack of a reliable means of assessing and comparing performance. We present here a reference set of serum and plasma samples to facilitate the validation of biomarkers for resectable pancreatic cancer. The reference set includes a large cohort of stage I-II pancreatic cancer patients, recruited from 5 different institutions, and relevant control groups. We characterized the performance of the current best serological biomarker for pancreatic cancer, CA 19–9, using plasma samples from the reference set to provide a benchmark for future biomarker studies and to further our knowledge of CA 19–9 in early-stage pancreatic cancer and the control groups. CA 19–9 distinguished pancreatic cancers from the healthy and chronic pancreatitis groups with an average sensitivity and specificity of 70–74%, similar to previous studies using all stages of pancreatic cancer. Chronic pancreatitis patients did not show CA 19–9 elevations, but patients with benign biliary obstruction had elevations nearly as high as the cancer patients. We gained additional information about the biomarker by comparing two distinct assays. The two CA 9–9 assays agreed well in overall performance but diverged in measurements of individual samples, potentially due to subtle differences in antibody specificity as revealed by glycan array analysis. Thus, the reference set promises be a valuable resource for biomarker validation and comparison, and the CA 19–9 data presented here will be useful for benchmarking and for exploring relationships to CA 19–9. PMID:26431551
Hormaechea-Agulla, Daniel; Gómez-Gómez, Enrique; Ibáñez-Costa, Alejandro; Carrasco-Valiente, Julia; Rivero-Cortés, Esther; L-López, Fernando; Pedraza-Arevalo, Sergio; Valero-Rosa, José; Sánchez-Sánchez, Rafael; Ortega-Salas, Rosa; Moreno, María M; Gahete, Manuel D; López-Miranda, José; Requena, María J; Castaño, Justo P; Luque, Raúl M
2016-12-01
Ghrelin-O-acyltransferase (GOAT) is the key enzyme regulating ghrelin activity, and has been proposed as a potential therapeutic target for obesity/diabetes and as a biomarker in some endocrine-related cancers. However, GOAT presence and putative role in prostate-cancer (PCa) is largely unknown. Here, we demonstrate, for the first time, that GOAT is overexpressed (mRNA/protein-level) in prostatic tissues (n = 52) and plasma/urine-samples (n = 85) of PCa-patients, compared with matched controls [healthy prostate tissues (n = 12) and plasma/urine-samples from BMI-matched controls (n = 28), respectively]. Interestingly, GOAT levels in PCa-patients correlated with aggressiveness and metabolic conditions (i.e. diabetes). Actually, GOAT expression was regulated by metabolic inputs (i.e. In1-ghrelin, insulin/IGF-I) in cultured normal prostate cells and PCa-cell lines. Importantly, ROC-curve analysis unveiled a valuable diagnostic potential for GOAT to discriminate PCa at the tissue/plasma/urine-level with high sensitivity/specificity, particularly in non-diabetic individuals. Moreover, we discovered that GOAT is secreted by PCa-cells, and that its levels are higher in urine samples from a stimulated post-massage vs. pre-massage prostate-test. In conclusion, plasmatic GOAT levels exhibit high specificity/sensitivity to predict PCa-presence compared with other PCa-biomarkers, especially in non-diabetic individuals, suggesting that GOAT holds potential as a novel non-invasive PCa-biomarker. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Inabu, Y; Saegusa, A; Inouchi, K; Koike, S; Oba, M; Sugino, T
2017-11-01
The objective of this study was to evaluate the effects of lactose inclusion in calf starters on plasma glucagon-like peptide (GLP)-1 and GLP-2 concentrations and gastrointestinal tract development in calves. Holstein bull calves (n = 45) were raised on an intensified nursing program using milk replacer containing 28.0% CP and 15.0% fat, and were fed a texturized calf starter containing 0 (control), 5.0 (LAC5), or 10.0% (LAC10; n = 15 for each treatment) lactose on a DM basis. Lactose was included in the starter by partially replacing dry ground corn in pelleted portion of the starter. All calf starters were formulated with 23.1% CP. The ethanol-soluble carbohydrate concentrations of the control, LAC5, and LAC10 starters were 7.3, 12.3, and 16.8% on a DM basis, respectively. Starch concentrations of the control, LAC5, and LAC10 starters were 29.7, 27.0, and 21.4% on a DM basis, respectively. All calves were fed treatment calf starters ad libitum. Blood samples were obtained weekly from 1 to 11 wk of age, and used to measure plasma GLP-1, GLP-2, and insulin concentrations, serum β-hydroxybutyrate (BHB) concentration, and blood glucose concentration. At 80 d of age, calves were euthanized, and weights of the reticulorumen, omasum, abomasum, small intestine, and large intestine tissue were measured. Serum BHB concentration was higher for calves fed the LAC10 (171 μmol/L) starter than for those fed the control (151 μmol/L) and LAC5 (145 μmol/L) starters. Plasma GLP-1 and GLP-2 concentrations did not differ between treatments. However, relative to the baseline (1 wk of age), the plasma GLP-1 concentration was higher for the LAC10 (125.9%) than for the LAC5 (68.2%) and control (36.8%), and for the LAC5 than for the control (36.8%). Moreover, similar differences between treatments were observed for GLP-2 concentration relative to the baseline (88.2, 76.9, and 74.9% for LAC10, LAC5, and control treatments, respectively). The serum BHB concentration was positively correlated with the plasma GLP-1 concentration (r = 0.428). Furthermore, the plasma GLP-1 concentration was positively correlated with the insulin concentration (r = 0.793). The weights of the reticulorumen, omasum, abomasum, small intestine, and large intestine were not affected by the treatments. In conclusion, inclusion of lactose in calf starters resulted in higher plasma GLP-1 and GLP-2 concentrations, and BHB might be associated with higher plasma GLP-1 concentration. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Conceptual Design of the ITER Plasma Control System
NASA Astrophysics Data System (ADS)
Snipes, J. A.
2013-10-01
The conceptual design of the ITER Plasma Control System (PCS) has been approved and the preliminary design has begun for the 1st plasma PCS. This is a collaboration of many plasma control experts from existing devices to design and test plasma control techniques applicable to ITER on existing machines. The conceptual design considered all phases of plasma operation, ranging from non-active H/He plasmas through high fusion gain inductive DT plasmas to fully non-inductive steady-state operation, to ensure that the PCS control functionality and architecture can satisfy the demands of the ITER Research Plan. The PCS will control plasma equilibrium and density, plasma heat exhaust, a range of MHD instabilities (including disruption mitigation), and the non-inductive current profile required to maintain stable steady-state scenarios. The PCS architecture requires sophisticated shared actuator management and event handling systems to prioritize control goals, algorithms, and actuators according to dynamic control needs and monitor plasma and plant system events to trigger automatic changes in the control algorithms or operational scenario, depending on real-time operating limits and conditions.
Pharmacokinetics, excretion of 8-cetylberberine and its main metabolites in rat urine.
Hu, Yuli; Fan, Shoujun; Liao, Xiaobing; Chen, Chao; Su, Liang; Li, Xuegang
2017-01-05
Berberine (BBR) is a bioactive plant ingredient derived from the roots and bark of Berberis aristata and Coptis chinensis and has a wide variety of pharmacological effects. 8-cetylberberine (8-BBR-C16) is the berberine (BBR) derivative reconstructed from adding octadecyl at C-8 of BBR to enhance its activity. This study presents a reliable method for the determination of BBR and 8-BBR-C16 in rat plasma, urine and feces. BBR and 8-BBR-C16 were determined by HPLC-UV after liquid-liquid extraction for plasma samples, and solid-phase extraction for urinary and fecal samples. The method was linear over the concentration range of 10-300 ng·ml -1 for the plasma samples, 25-2000 ng·ml -1 for the urinary samples, and 100-2000 ng·g -1 for the fecal samples. Furthermore, a metabolic investigation on urine was performed by LC/MS/MS analysis to identify the structures of 8-BBR-C16 metabolites by full scan and product ion scan. Adult Sprague-Dawley rats were divided into two groups. In the control group, rats received 80 mg·kg -1 BBR, and in the drug-treated group, rats received 80 mg·kg -1 8-BBR-C16. The results indicate that there were significant differences in the pharmacokinetic parameters and in the accumulated excretion levels between the control group and the drug-treated group. The C max and AUC 0-t of 8-BBR-C16 were 2.8 and 12.9 times higher than those of BBR, and the relative bioavailability of BBR to 8-BBR-C16 was 7.7%. The total excretion amount through the urine and feces of 8-BBR-C16 was 76.9%, but that of BBR was only 20.5%. Additionally, 8-BBR-C16 was metabolized in rat urine with phase I demethylation and phase II glucuronidation or sulfation. Copyright © 2016 Elsevier B.V. All rights reserved.
Kaabia, Z; Dervilly-Pinel, G; Popot, M A; Bailly-Chouriberry, L; Plou, P; Bonnaire, Y; Le Bizec, B
2014-04-01
Nandrolone (17β-hydroxy-4-estren-3-one) is amongst the most misused endogenous steroid hormones in entire male horses. The detection of such a substance is challenging with regard to its endogenous presence. The current international threshold level for nandrolone misuse is based on the urinary concentration ratio of 5α-estrane-3β,17α-diol (EAD) to 5(10)-estrene-3β,17α-diol (EED). This ratio, however, can be influenced by a number of factors due to existing intra- and inter-variability standing, respectively, for the variation occurring in endogenous steroids concentration levels in a single subject and the variation in those same concentration levels observed between different subjects. Targeting an efficient detection of nandrolone misuse in entire male horses, an analytical strategy was set up in order to profile a group of endogenous steroids in nandrolone-treated and non-treated equines. Experiment plasma and urine samples were steadily collected over more than three months from a stallion administered with nandrolone laurate (1 mg/kg). Control plasma and urine samples were collected monthly from seven non-treated stallions over a one-year period. A large panel of steroids of interest (n = 23) were extracted from equine urine and plasma samples using a C18 cartridge. Following a methanolysis step, liquid-liquid and solid-phase extractions purifications were performed before derivatization and analysis on gas chromatography-tandem mass spectrometry (GC-MS/MS) for quantification. Statistical processing of the collected data permitted to establish statistical models capable of discriminating control samples from those collected during the three months following administration. Furthermore, these statistical models succeeded in predicting the compliance status of additional samples collected from racing horses. Copyright © 2013 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Zhang, Chunming; Zhao, Meihua; Wang, Libing; Qu, Lijun; Men, Yajing
2017-04-01
Surface properties of water-based pigmented inks for ink-jet printed polyester fabrics were modified with atmospheric-pressure air/He plasma to improve the color strength and pigment adhesion of the treated surfaces. The influence of various parameters, including the surface morphology, chemical compositions, surface energy and dynamic contact angles of the control and plasma treated samples was studied. Color strength and edge definition were used to evaluate the ink-jet printing performance of fabrics. The change in pigment adhesion to polyester fibers was analyzed by SEM (scanning electron microscopy). AFM (Atomic force microscope) and XPS (X-ray photoelectron spectroscopy) analyses indicated the increase in surface roughness and the oxygen-containing polar groups(Cdbnd O, Csbnd OH and COOH) reinforced the fixation of pigments on the fiber surface. The result from this study suggested that the improved pigment color yield was clearly affected by alteration of pigment adhesion enhanced by plasma surface modification. Polyester fabrics exhibited better surface property and ink-jet printing performance after the air/He mixture plasma treatment comparing with those after air plasma treatment.
Plasma endotoxin activity in Eastern grey kangaroos (Macropus giganteus) with lumpy jaw disease
SOTOHIRA, Yukari; SUZUKI, Kazuyuki; OTSUKA, Marina; TSUCHIYA, Masakazu; SHIMAMORI, Toshio; NISHI, Yasunobu; TSUKANO, Kenji; ASAKAWA, Mitsuhiko
2017-01-01
Progressive pyogranulomatous osteomyelitis involving the mandible or maxilla of captive macropods, referred to as “Lumpy jaw disease (LJD)”, is one of the most significant causes of illness and death in captive macropods. The aim of the present study was to evaluate the relationship between the severity of LJD and plasma endotoxin activity in kangaroos. Plasma samples obtained from moderate (n=24) and severe LJD (n=12), and healthy kangaroos (n=46), were diluted 1:20 in endotoxin-free water and heated to 80°C for 10 min. Plasma endotoxin activity was measured using the Limulus amebocyte lysate (LAL)-kinetic turbidimetric (KT) assay. Plasma endotoxin activity was higher in kangaroos with severe LJD (0.199 ± 0.157 EU/ml) than in those with moderate LJD (0.051 ± 0.012 EU/ml, P<0.001) and healthy controls (0.057 ± 0.028 EU/ml, P<0.001). Our results suggest that the severity of LJD in captive macropods may be related to the plasma endotoxin activity. PMID:28484148
Characterization of boronized graphite in NSTX-U and its effect on plasma performance
NASA Astrophysics Data System (ADS)
Bedoya, Felipe; Allain, Jean Paul; Kaita, Robert; Skinner, Charles; University of Illinois Team; Princeton Plasma Physics Laboratory Collaboration
2017-10-01
Plasma Facing Components (PFC) conditioning can have a crucial influence in plasma performance in tokamak machines. The National Spherical Torus Experiment (NSTX-U) used boronization as the main wall conditioning technique during the FY16 experimental campaign. The Materials Analysis Particle Probe (MAPP), a characterization facility, was used to investigate the surface of ATJ graphite exposed to boronization and plasma in the tokamak using X-ray Photoelectron Spectroscopy (XPS). The measurements showed that plasma induced oxidation plays a critical role in the chemical evolution of the surfaces and as a consequence in plasma performance. Additionally, ex-vessel in-situ laboratory experiments and post-mortem studies of extracted NSTX-U tiles were performed to complement the observations made with MAPP, including controlled D irradiations and XPS depth profiles. These three methodologies show congruent results where D exposures increase the oxygen concentration between 20-30%, highlighting the influence of these two species on the chemistry of the samples. USDOE Contract DE-AC02-09CH11466, USDOE Contract DE-SC0010717 and Award Number DE-SC0012890.
Kamande, Joyce W; Lindell, Maria A M; Witek, Małgorzata A; Voorhees, Peter M; Soper, Steven A
2018-02-19
Blood samples from patients with plasma cell disorders were analysed for the presence of circulating plasma cells (CPCs) using a microfluidic device modified with monoclonal anti-CD138 antibodies. CPCs were immuno-phenotyped using a CD38/CD56/CD45 panel and identified in 78% of patients with monoclonal gammopathy of undetermined significance (MGUS), all patients with smouldering and symptomatic multiple myeloma (MM), and none in the controls. The burden of CPCs was higher in patients with symptomatic MM compared with MGUS and smouldering MM (p < 0.05). FISH analysis revealed the presence of chromosome 13 deletions in CPCs that correlated with bone marrow results. Point mutations in KRAS were identified, including different mutations from sub-clones derived from the same patient. The microfluidic assay represents a highly sensitive method for enumerating CPCs and allows for the cytogenetic and molecular characterization of CPCs.
Ishiwata, Sayuri; Hattori, Kotaro; Sasayama, Daimei; Teraishi, Toshiya; Miyakawa, Tomoko; Yokota, Yuuki; Matsumura, Ryo; Nishikawa, Toru; Kunugi, Hiroshi
2018-01-15
D-serine is an endogenous co-agonist of N-methyl-D-aspartate receptor (NMDAR) and plays an important role in glutamate neurotransmission. Several studies suggested the possible involvement of D-serine related in the pathophysiology of psychiatric disorders including major depression disorders (MDD). We tried to examine whether cerebrospinal fluid (CSF) or plasma D-serine concentrations are altered in MDD and whether D-serine concentrations correlated with disease severity. 26 MDD patients and 27 healthy controls matched for age, sex and ethnicity were enrolled. We measured amino acids in these samples using by high-performance liquid chromatography with fluorometric detection. D-serine and L-serine, precursor of D-serine, levels in CSF or plasma were not significantly different in patients of MDD compared to controls. Furthermore, a significant correlation between D-serine levels in CSF and Hamilton Depression Rating Scale (HAMD)-17 score was observed (r = -0.65, p = 0.006). Furthermore, we found a positive correlation between CSF D-serine and HVA concentrations in MDD patients (r = 0.54, p = 0.007). CSF D-serine concentrations were correlated with those of plasma in MDD (r = 0.61, p = 0.01) but not in controls. In CSF, we also confirmed a significant correlation between D-serine and L-serine levels in MDD (r = 0.72, p < 0.0001) and controls (r = 0.70, p < 0.0001). The study has some limitations; sample size was relatively small and most patients were medicated. We revealed that CSF D-serine concentrations were correlated with depression severity and HVA concentrations and further investigation were required to reveal the effect of medication and disease heterogeneity. Copyright © 2017 Elsevier B.V. All rights reserved.
Regulation of plasma agouti-related protein and its relationship with hunger in lean and obese men.
Hazell, Tom J; Sawula, Laura; Edgett, Brittany A; Walsh, Jeremy J; Gurd, Brendon J
2016-12-01
Agouti-related protein (AgRP) is an orexigenic (appetite stimulating) neuropeptide suggested to exert tonic control over long-term energy balance. While some have speculated AgRP is not involved in the episodic (i.e. meal to meal energy intake) control, acute decreases in plasma agouti-related protein (AgRP) following a meal have been observed in humans in a role consistent with episodic control for AgRP. Whether changes in plasma AgRP are associated with episodic, and/or tonic changes in appetite has yet to be directly examined. The present study examined the relationship between agouti-related protein (AgRP), leptin and the regulation of appetite following a 48-h fast and an acute meal challenge. Blood samples were obtained from young lean and obese men before and after a 48 h fast (lean n = 10; obese n = 7). Fasting resulted in an increase in AgRP and a decrease in leptin with these changes being greater in lean than obese. In addition, blood samples were obtained from lean men before and 1, 2, 3 and 4 h after a meal (n = 8). Following a meal, AgRP was reduced from 2 to 4 h, a change that was dissociated from both leptin and subjective measures of hunger and satiety. These results demonstrate that AgRP is not associated with changes in hunger or satiety, and can change without corresponding changes in leptin. This suggests that AgRP may not be involved in the episodic control of appetite and the release of AgRP may involve signals other than leptin. Copyright © 2016 Elsevier Ltd. All rights reserved.
Leitner, Miriam; Fragner, Lena; Danner, Sarah; Holeschofsky, Nastassja; Leitner, Karoline; Tischler, Sonja; Doerfler, Hannes; Bachmann, Gert; Sun, Xiaoliang; Jaeger, Walter; Kautzky-Willer, Alexandra; Weckwerth, Wolfram
2017-01-01
Gestational diabetes mellitus during pregnancy has severe implications for the health of the mother and the fetus. Therefore, early prediction and an understanding of the physiology are an important part of prenatal care. Metabolite profiling is a long established method for the analysis and prediction of metabolic diseases. Here, we applied untargeted and targeted metabolomic protocols to analyze plasma and urine samples of pregnant women with and without GDM. Univariate and multivariate statistical analyses of metabolomic profiles revealed markers such as 2-hydroxybutanoic acid (AHBA), 3-hydroxybutanoic acid (BHBA), amino acids valine and alanine, the glucose-alanine-cycle, but also plant-derived compounds like sitosterin as different between control and GDM patients. PLS-DA and VIP analysis revealed tryptophan as a strong variable separating control and GDM. As tryptophan is biotransformed to serotonin we hypothesized whether serotonin metabolism might also be altered in GDM. To test this hypothesis we applied a method for the analysis of serotonin, metabolic intermediates and dopamine in urine by stable isotope dilution direct infusion electrospray ionization mass spectrometry (SID-MS). Indeed, serotonin and related metabolites differ significantly between control and GDM patients confirming the involvement of serotonin metabolism in GDM. Clustered correlation coefficient visualization of metabolite correlation networks revealed the different metabolic signatures between control and GDM patients. Eventually, the combination of selected blood plasma and urine sample metabolites improved the AUC prediction accuracy to 0.99. The detected GDM candidate biomarkers and the related systemic metabolic signatures are discussed in their pathophysiological context. Further studies with larger cohorts are necessary to underpin these observations. PMID:29312952
Zhao, Jia-Guo; Zhao, Li; Jiang, Yan-Xia; Wang, Zeng-Liang; Wang, Jia; Zhang, Peng
2015-01-01
The purpose of this study was to appraise the retear rate and clinical outcomes of platelet-rich plasma use in patients undergoing arthroscopic full-thickness rotator cuff repair. We searched the Cochrane Library, PubMed, and EMBASE databases for randomized controlled trials comparing the outcomes of arthroscopic rotator cuff surgery with or without the use of platelet-rich plasma. Methodological quality was assessed by the Detsky quality scale. When there was no high heterogeneity, we used a fixed-effects model. Dichotomous variables were presented as risk ratios (RRs) with 95% confidence intervals (CIs), and continuous data were measured as mean differences with 95% CIs. The Grading of Recommendations Assessment, Development, and Evaluation (GRADE) system was used to assess the quality of evidence for each individual outcome. Eight randomized controlled trials were included, with the sample size ranging from 28 to 88. Overall methodological quality was high. Fixed-effects analysis showed that differences were not significant between the 2 groups in retear rate (RR, 0.94; 95% CI, 0.70 to 1.25; P = .66), Constant score (mean difference, 1.12; 95% CI, -1.38 to 3.61; P = .38), and University of California at Los Angeles (UCLA) score (mean difference, -0.68; 95% CI, -2.00 to 0.65; P = .32). The strength of GRADE evidence was categorized respectively as low for retear, moderate for Constant score, and low for UCLA shoulder score. Our meta-analysis does not support the use of platelet-rich plasma in the arthroscopic repair of full-thickness rotator cuff tears over repairs without platelet-rich plasma because of similar retear rates and clinical outcomes. Level II, meta-analysis of Level I and II randomized controlled trials. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Messenger, K M; Wofford, J A; Papich, M G
2016-02-01
Measurement of unbound drug concentrations at their sites of action is necessary for accurate PK/PD modeling. The objective of this study was to determine the unbound concentration of carprofen in canine interstitial fluid (ISF) using in vivo ultrafiltration and to compare pharmacokinetic parameters of free carprofen concentrations between inflamed and control tissue sites. We hypothesized that active concentrations of carprofen would exhibit different dispositions in ISF between inflamed vs. normal tissues. Bilateral ultrafiltration probes were placed subcutaneously in six healthy Beagle dogs 12 h prior to induction of inflammation. Two milliliters of either 2% carrageenan or saline control was injected subcutaneously at each probe site, 12 h prior to intravenous carprofen (4 mg/kg) administration. Plasma and ISF samples were collected at regular intervals for 72 h, and carprofen concentrations were determined using HPLC. Prostaglandin E2 (PGE2 ) concentrations were quantified in ISF using ELISA. Unbound carprofen concentrations were higher in ISF compared with predicted unbound plasma drug concentrations. Concentrations were not significantly higher in inflamed ISF compared with control ISF. Compartmental modeling was used to generate pharmacokinetic parameter estimates, which were not significantly different between sites. Terminal half-life (T½) was longer in the ISF compared with plasma. PGE2 in ISF decreased following administration of carprofen. In vivo ultrafiltration is a reliable method to determine unbound carprofen in ISF, and that disposition of unbound drug into tissue is much higher than predicted from unbound drug concentration in plasma. However, concentrations and pharmacokinetic parameter estimates are not significantly different in inflamed vs. un-inflamed tissues. © 2015 John Wiley & Sons Ltd.
Comparison of cross-sectional HIV incidence assay results from dried blood spots and plasma.
Schlusser, Katherine E; Pilcher, Christopher; Kallas, Esper G; Santos, Breno R; Deeks, Steven G; Facente, Shelley; Keating, Sheila M; Busch, Michael P; Murphy, Gary; Welte, Alex; Quinn, Thomas; Eshleman, Susan H; Laeyendecker, Oliver
2017-01-01
Assays have been developed for cross-sectional HIV incidence estimation using plasma samples. Large scale surveillance programs are planned using dried blood spot (DBS) specimens for incidence assessment. However, limited information exists on the performance of HIV cross-sectional incidence assays using DBS. The assays evaluated were: Maxim HIV-1 Limiting Antigen Avidity EIA (LAg-Avidity), Sedia HIV-1 BED-Capture EIA (BED-CEIA), and CDC modified BioRad HIV-1/2 Plus O Avidity-based Assay (CDC-BioRad Avidity) using pre-determined cutoff values. 100 matched HIV-1 positive plasma and DBS samples, with known duration of infection, from the Consortium for the Evaluation and Performance of HIV Incidence Assays repository were tested. All assays were run in duplicate. To examine the degree of variability within and between results for each sample type, both categorical and continuous results were analyzed. Associations were assessed with Bland Altman, R2 values and Cohen's kappa coefficient (ĸ). Intra-assay variability using the same sample type was similar for all assays (R2 0.96 to 1.00). The R2 values comparing DBS and plasma results for LAg-Avidity, BED-CEIA, and CDC-BioRad Avidity were 0.96, 0.94, and 0.84, respectively. The concordance and ĸ values between DBS and plasma for all three assays were >87% and >0.64, respectively. The Bland-Altman analysis showed significant differences between plasma and DBS samples. For all three assays, a higher number of samples were classified as recent infections using DBS samples. DBS and plasma sample results were highly correlated. However, when compared to plasma, each assay performed somewhat differently in DBS at the lower and higher ends of the dynamic range. DBS samples were more likely to be classified as recently infected by all three assays, which may lead to overestimation of incidence in surveys using performance criteria derived for plasma samples.
Zambrano, Hector; Waggoner, Jesse; León, Karina; Pinsky, Benjamin; Vera, Ketty; Schettino, Marissa; Rivera, Lisette; Landivar, José; Granda, María; Lee, Angela; Mor, Gil
2017-02-01
Zika virus (ZIKV) infection during pregnancy has been linked to severe birth defects, and the epidemiologic situation of the ZIKV epidemic in Ecuador is poorly understood. Guayaquil, Ecuador, has a tropical climate and experiences frequent outbreaks of dengue and chikungunya virus, and in December 2015, ZIKV was identified. Given the well-documented effects of ZIKV in pregnancy, including microcephaly, we tested for the presence of ZIKV in both plasma and cervical cytology of pregnant women. We report the identification of a population of pregnant women with a high incidence of ZIKV infection detected in the plasma and lower reproductive tract. A case-control study was performed to determine the incidence of ZIKV infection among low-income, pregnant women at risk for preterm delivery compared to matched controls. Plasma and cervical cytology specimens were tested for ZIKV by rRT-PCR. Fifty-nine pregnant women were enrolled. The incidence of ZIKV was 54% (32/59) overall: 18/31 (58.1%) in cases and 14/28 (50.0%) in controls. ZIKV detection in plasma and cervical cytology specimens demonstrated good agreement. Overall, outcomes for neonates born to ZIKV-positive and ZIKV-negative mothers were similar. However, two neonates were born with microcephaly to case mothers who were ZIKV positive. We report a high incidence of ZIKV infection (54%) in a distinctive population in Guayaquil, Ecuador. We identify ZIKV in cervical samples that correlates with ZIKV in the plasma. These data raise concerns regarding the breadth of the ZIKV epidemic in Ecuador and demonstrate the utility of cervical cytology specimens for ZIKV testing. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Lerner, Darrren T.; Bjornsson, Bjorn Thrandur; McCormick, Stephen D.
2007-01-01
Population declines of wild Atlantic salmon have been attributed to an array of anthropogenic disturbances, including dams, commercial and recreational fishing, habitat loss, and pollution. Environmental contaminants in particular, can act as environmental stressors on fish, typically causing disruption of ion homeostasis due to their close association with the aquatic environment. To examine the effects of the xenoestrogen 4-nonylphenol (NP) or 17β-estradiol (E2) on stress sensitivity and ion regulation, we exposed juvenile Atlantic salmon continuously for 21 d to either 10 or 100 μg/L NP (NP-L or NP-H), 2 μg/L E2 (positive control), or vehicle control during the parr-smolt transformation in April. After treatment, fish were sampled in freshwater (FW), transferred to 30‰ seawater (SW) for 24 h, or subjected to a handling stress. Estradiol and NP-H increased plasma vitellogenin in males and females, and E2 increased gonadosomatic index only in males. In FW, E2 reduced sodium potassium–activated adenosine triphosphatase activity as well as plasma levels of growth hormone, insulin-like growth factor I, and triiodothyronine. Both E2 and NP-H reduced plasma sodium in FW and increased plasma chloride in SW. Plasma Cortisol levels pre- and poststressor were significantly elevated by all treatments relative to controls, but only E2 increased plasma glucose before and after the stressor. These results indicate that exposure of anadromous salmonids to environmental estrogens heightens sensitivity to external stressors, impairs ion regulation in both FW and SW, and disrupts endocrine pathways critical for smolt development.