Bon-EV: an improved multiple testing procedure for controlling false discovery rates.
Li, Dongmei; Xie, Zidian; Zand, Martin; Fogg, Thomas; Dye, Timothy
2017-01-03
Stability of multiple testing procedures, defined as the standard deviation of total number of discoveries, can be used as an indicator of variability of multiple testing procedures. Improving stability of multiple testing procedures can help to increase the consistency of findings from replicated experiments. Benjamini-Hochberg's and Storey's q-value procedures are two commonly used multiple testing procedures for controlling false discoveries in genomic studies. Storey's q-value procedure has higher power and lower stability than Benjamini-Hochberg's procedure. To improve upon the stability of Storey's q-value procedure and maintain its high power in genomic data analysis, we propose a new multiple testing procedure, named Bon-EV, to control false discovery rate (FDR) based on Bonferroni's approach. Simulation studies show that our proposed Bon-EV procedure can maintain the high power of the Storey's q-value procedure and also result in better FDR control and higher stability than Storey's q-value procedure for samples of large size(30 in each group) and medium size (15 in each group) for either independent, somewhat correlated, or highly correlated test statistics. When sample size is small (5 in each group), our proposed Bon-EV procedure has performance between the Benjamini-Hochberg procedure and the Storey's q-value procedure. Examples using RNA-Seq data show that the Bon-EV procedure has higher stability than the Storey's q-value procedure while maintaining equivalent power, and higher power than the Benjamini-Hochberg's procedure. For medium or large sample sizes, the Bon-EV procedure has improved FDR control and stability compared with the Storey's q-value procedure and improved power compared with the Benjamini-Hochberg procedure. The Bon-EV multiple testing procedure is available as the BonEV package in R for download at https://CRAN.R-project.org/package=BonEV .
Apollo experience report: Systems and flight procedures development
NASA Technical Reports Server (NTRS)
Kramer, P. C.
1973-01-01
This report describes the process of crew procedures development used in the Apollo Program. The two major categories, Systems Procedures and Flight Procedures, are defined, as are the forms of documentation required. A description is provided of the operation of the procedures change control process, which includes the roles of man-in-the-loop simulations and the Crew Procedures Change Board. Brief discussions of significant aspects of the attitude control, computer, electrical power, environmental control, and propulsion subsystems procedures development are presented. Flight procedures are subdivided by mission phase: launch and translunar injection, rendezvous, lunar descent and ascent, and entry. Procedures used for each mission phase are summarized.
Risk Control Through the Use of Procedures - A Method for Evaluating the Change in Risk
NASA Technical Reports Server (NTRS)
Praino, Gregory; Sharit, Joseph
2010-01-01
Organizations use procedures to influence or control the behavior of their workers, but often have no basis for determining whether an additional rule, or procedural control will be beneficial. This paper outlines a proposed method for determining if the addition or removal of procedural controls will impact the occurrences of critical consequences. The proposed method focuses on two aspects: how valuable the procedural control is, based on the inevitability of the consequence and the opportunity to intervene; and how likely the control is to fail, based on five procedural design elements that address how well the rule or control has been Defined, Assigned, Trained, Organized and Monitored-referred to as the DATOM elements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hance, R.; /Fermilab
1998-08-26
This procedure is used when it is necessary to operate the solenoid energization, controls, interlocks and quench detection system. Note that a separate procedure exists for operating the solenoid 'cryogenic' systems. Only D0 Control Room Operators or the Project Electrical Engineer are qualified to execute these procedures or operate the solenoid system. This procedure assumes that the operator is familiar with using the Distributed Manufacturing Automation and Control Software (DMACS).
Automated procedure execution for space vehicle autonomous control
NASA Technical Reports Server (NTRS)
Broten, Thomas A.; Brown, David A.
1990-01-01
Increased operational autonomy and reduced operating costs have become critical design objectives in next-generation NASA and DoD space programs. The objective is to develop a semi-automated system for intelligent spacecraft operations support. The Spacecraft Operations and Anomaly Resolution System (SOARS) is presented as a standardized, model-based architecture for performing High-Level Tasking, Status Monitoring and automated Procedure Execution Control for a variety of spacecraft. The particular focus is on the Procedure Execution Control module. A hierarchical procedure network is proposed as the fundamental means for specifying and representing arbitrary operational procedures. A separate procedure interpreter controls automatic execution of the procedure, taking into account the current status of the spacecraft as maintained in an object-oriented spacecraft model.
Operator procedure verification with a rapidly reconfigurable simulator
NASA Technical Reports Server (NTRS)
Iwasaki, Yumi; Engelmore, Robert; Fehr, Gary; Fikes, Richard
1994-01-01
Generating and testing procedures for controlling spacecraft subsystems composed of electro-mechanical and computationally realized elements has become a very difficult task. Before a spacecraft can be flown, mission controllers must envision a great variety of situations the flight crew may encounter during a mission and carefully construct procedures for operating the spacecraft in each possible situation. If, despite extensive pre-compilation of control procedures, an unforeseen situation arises during a mission, the mission controller must generate a new procedure for the flight crew in a limited amount of time. In such situations, the mission controller cannot systematically consider and test alternative procedures against models of the system being controlled, because the available simulator is too large and complex to reconfigure, run, and analyze quickly. A rapidly reconfigurable simulation environment that can execute a control procedure and show its effects on system behavior would greatly facilitate generation and testing of control procedures both before and during a mission. The How Things Work project at Stanford University has developed a system called DME (Device Modeling Environment) for modeling and simulating the behavior of electromechanical devices. DME was designed to facilitate model formulation and behavior simulation of device behavior including both continuous and discrete phenomena. We are currently extending DME for use in testing operator procedures, and we have built a knowledge base for modeling the Reaction Control System (RCS) of the space shuttle as a testbed. We believe that DME can facilitate design of operator procedures by providing mission controllers with a simulation environment that meets all these requirements.
A Comparison of Exposure Control Procedures in CATs Using the 3PL Model
ERIC Educational Resources Information Center
Leroux, Audrey J.; Lopez, Myriam; Hembry, Ian; Dodd, Barbara G.
2013-01-01
This study compares the progressive-restricted standard error (PR-SE) exposure control procedure to three commonly used procedures in computerized adaptive testing, the randomesque, Sympson-Hetter (SH), and no exposure control methods. The performance of these four procedures is evaluated using the three-parameter logistic model under the…
Optimal False Discovery Rate Control for Dependent Data
Xie, Jichun; Cai, T. Tony; Maris, John; Li, Hongzhe
2013-01-01
This paper considers the problem of optimal false discovery rate control when the test statistics are dependent. An optimal joint oracle procedure, which minimizes the false non-discovery rate subject to a constraint on the false discovery rate is developed. A data-driven marginal plug-in procedure is then proposed to approximate the optimal joint procedure for multivariate normal data. It is shown that the marginal procedure is asymptotically optimal for multivariate normal data with a short-range dependent covariance structure. Numerical results show that the marginal procedure controls false discovery rate and leads to a smaller false non-discovery rate than several commonly used p-value based false discovery rate controlling methods. The procedure is illustrated by an application to a genome-wide association study of neuroblastoma and it identifies a few more genetic variants that are potentially associated with neuroblastoma than several p-value-based false discovery rate controlling procedures. PMID:23378870
The procedure execution manager and its application to Advanced Photon Source operation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borland, M.
1997-06-01
The Procedure Execution Manager (PEM) combines a complete scripting environment for coding accelerator operation procedures with a manager application for executing and monitoring the procedures. PEM is based on Tcl/Tk, a supporting widget library, and the dp-tcl extension for distributed processing. The scripting environment provides support for distributed, parallel execution of procedures along with join and abort operations. Nesting of procedures is supported, permitting the same code to run as a top-level procedure under operator control or as a subroutine under control of another procedure. The manager application allows an operator to execute one or more procedures in automatic, semi-automatic,more » or manual modes. It also provides a standard way for operators to interact with procedures. A number of successful applications of PEM to accelerator operations have been made to date. These include start-up, shutdown, and other control of the positron accumulator ring (PAR), low-energy transport (LET) lines, and the booster rf systems. The PAR/LET procedures make nested use of PEM`s ability to run parallel procedures. There are also a number of procedures to guide and assist tune-up operations, to make accelerator physics measurements, and to diagnose equipment. Because of the success of the existing procedures, expanded use of PEM is planned.« less
A design procedure and handling quality criteria for lateral directional flight control systems
NASA Technical Reports Server (NTRS)
Stein, G.; Henke, A. H.
1972-01-01
A practical design procedure for aircraft augmentation systems is described based on quadratic optimal control technology and handling-quality-oriented cost functionals. The procedure is applied to the design of a lateral-directional control system for the F4C aircraft. The design criteria, design procedure, and final control system are validated with a program of formal pilot evaluation experiments.
Smets, Tinne; Bilsen, Johan; Cohen, Joachim; Rurup, Mette L; De Keyser, Els; Deliens, Luc
2009-05-01
To describe and compare current legal procedures for notifying, controlling and evaluating (NCE-procedures) euthanasia in Belgium and the Netherlands, and to discuss the implications for a safe and controllable euthanasia practice. We systematically studied and compared official documents relating to the Belgian and the Dutch NCE-procedures for euthanasia. In both countries, physicians are required to notify their cases to a review Committee, stimulating them to safeguard the quality of their euthanasia practice and to make societal control over the practice of euthanasia possible. However, the procedures in both countries differ. The main differences are that the Dutch notification and control procedures are more elaborate and transparent than the Belgian, and that the Belgian procedures are primarily anonymous, whereas the Dutch are not. Societal evaluation is made in both countries through the Committees' summary reports to Parliament. Transparent procedures like the Dutch may better facilitate societal control. Informing physicians about the law and the due care requirements for euthanasia, and systematic feedback about their medical actions are both pivotal to achieving efficient societal control and engendering the level of care needed when performing such far-reaching medical acts.
41 CFR 109-27.5007-1 - Procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
...-INVENTORY MANAGEMENT 27.50-Inventory Management Policies, Procedures, and Guidelines § 109-27.5007-1 Procedures. The following procedures shall be established for taking physical inventory of stocks subjected to quantity controls as well as those under financial control: (a) Completion of a physical inventory...
Sibbitt, Wilmer; Sibbitt, Randy R; Michael, Adrian A; Fu, Druce I; Draeger, Hilda T; Twining, Jon M; Bankhurst, Arthur D
2006-04-01
To evaluate physician control of needle and syringe during aspiration-injection syringe procedures by comparing the new reciprocating procedure syringe to a traditional conventional syringe. Twenty-six physicians were tested for their individual ability to control the reciprocating and conventional syringes in typical aspiration-injection procedures using a novel quantitative needle-based displacement procedure model. Subsequently, the physicians performed 48 clinical aspiration-injection (arthrocentesis) procedures on 32 subjects randomized to the reciprocating or conventional syringes. Clinical outcomes included procedure time, patient pain, and operator satisfaction. Multivariate modeling methods were used to determine the experimental variables in the syringe control model most predictive of clinical outcome measures. In the model system, the reciprocating syringe significantly improved physician control of the syringe and needle, with a 66% reduction in unintended forward penetration (p < 0.001) and a 68% reduction in unintended retraction (p < 0.001). In clinical arthrocentesis, improvements were also noted: 30% reduction in procedure time (p < 0.03), 57% reduction in patient pain (p < 0.001), and a 79% increase in physician satisfaction (p < 0.001). The variables in the experimental system--unintended forward penetration, unintended retraction, and operator satisfaction--independently predicted the outcomes of procedure time, patient pain, and physician satisfaction in the clinical study (p < or = 0.001). The reciprocating syringe reduces procedure time and patient pain and improves operator satisfaction with the procedure syringe. The reciprocating syringe improves physician performance in both the validated quantitative needle-based displacement model and in real aspiration-injection syringe procedures, including arthrocentesis.
Computerized procedures system
Lipner, Melvin H.; Mundy, Roger A.; Franusich, Michael D.
2010-10-12
An online data driven computerized procedures system that guides an operator through a complex process facility's operating procedures. The system monitors plant data, processes the data and then, based upon this processing, presents the status of the current procedure step and/or substep to the operator. The system supports multiple users and a single procedure definition supports several interface formats that can be tailored to the individual user. Layered security controls access privileges and revisions are version controlled. The procedures run on a server that is platform independent of the user workstations that the server interfaces with and the user interface supports diverse procedural views.
Davis, Laurie Laughlin; Dodd, Barbara G
2008-01-01
Exposure control research with polytomous item pools has determined that randomization procedures can be very effective for controlling test security in computerized adaptive testing (CAT). The current study investigated the performance of four procedures for controlling item exposure in a CAT under the partial credit model. In addition to a no exposure control baseline condition, the Kingsbury-Zara, modified-within-.10-logits, Sympson-Hetter, and conditional Sympson-Hetter procedures were implemented to control exposure rates. The Kingsbury-Zara and the modified-within-.10-logits procedures were implemented with 3 and 6 item candidate conditions. The results show that the Kingsbury-Zara and modified-within-.10-logits procedures with 6 item candidates performed as well as the conditional Sympson-Hetter in terms of exposure rates, overlap rates, and pool utilization. These two procedures are strongly recommended for use with partial credit CATs due to their simplicity and strength of their results.
40 CFR 63.752 - Recordkeeping requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... efficiency of the control system (as determined using the procedures specified in § 63.750(h)) and all test... adsorber: (i) The overall control efficiency of the control system (as determined using the procedures... overall control efficiency of the control system (as determined using the procedures specified in § 63.750...
40 CFR 63.752 - Recordkeeping requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... efficiency of the control system (as determined using the procedures specified in § 63.750(h)) and all test... adsorber: (i) The overall control efficiency of the control system (as determined using the procedures... overall control efficiency of the control system (as determined using the procedures specified in § 63.750...
40 CFR 63.752 - Recordkeeping requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... efficiency of the control system (as determined using the procedures specified in § 63.750(h)) and all test... adsorber: (i) The overall control efficiency of the control system (as determined using the procedures... overall control efficiency of the control system (as determined using the procedures specified in § 63.750...
40 CFR 63.752 - Recordkeeping requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... efficiency of the control system (as determined using the procedures specified in § 63.750(h)) and all test... adsorber: (i) The overall control efficiency of the control system (as determined using the procedures... overall control efficiency of the control system (as determined using the procedures specified in § 63.750...
40 CFR 63.752 - Recordkeeping requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... efficiency of the control system (as determined using the procedures specified in § 63.750(h)) and all test... adsorber: (i) The overall control efficiency of the control system (as determined using the procedures... overall control efficiency of the control system (as determined using the procedures specified in § 63.750...
Automatic control design procedures for restructurable aircraft control
NASA Technical Reports Server (NTRS)
Looze, D. P.; Krolewski, S.; Weiss, J.; Barrett, N.; Eterno, J.
1985-01-01
A simple, reliable automatic redesign procedure for restructurable control is discussed. This procedure is based on Linear Quadratic (LQ) design methodologies. It employs a robust control system design for the unfailed aircraft to minimize the effects of failed surfaces and to extend the time available for restructuring the Flight Control System. The procedure uses the LQ design parameters for the unfailed system as a basis for choosing the design parameters of the failed system. This philosophy alloys the engineering trade-offs that were present in the nominal design to the inherited by the restructurable design. In particular, it alloys bandwidth limitations and performance trade-offs to be incorporated in the redesigned system. The procedure also has several other desirable features. It effectively redistributes authority among the available control effectors to maximize the system performance subject to actuator limitations and constraints. It provides a graceful performance degradation as the amount of control authority lessens. When given the parameters of the unfailed aircraft, the automatic redesign procedure reproduces the nominal control system design.
Operational Control Procedures for the Activated Sludge Process, Part III-A: Calculation Procedures.
ERIC Educational Resources Information Center
West, Alfred W.
This is the second in a series of documents developed by the National Training and Operational Technology Center describing operational control procedures for the activated sludge process used in wastewater treatment. This document deals exclusively with the calculation procedures, including simplified mixing formulas, aeration tank…
21 CFR 123.11 - Sanitation control procedures.
Code of Federal Regulations, 2012 CFR
2012-04-01
... procedures. (a) Sanitation SOP. Each processor should have and implement a written sanitation standard operating procedure (herein referred to as SSOP) or similar document that is specific to each location where... 21 Food and Drugs 2 2012-04-01 2012-04-01 false Sanitation control procedures. 123.11 Section 123...
21 CFR 123.11 - Sanitation control procedures.
Code of Federal Regulations, 2014 CFR
2014-04-01
... procedures. (a) Sanitation SOP. Each processor should have and implement a written sanitation standard operating procedure (herein referred to as SSOP) or similar document that is specific to each location where... 21 Food and Drugs 2 2014-04-01 2014-04-01 false Sanitation control procedures. 123.11 Section 123...
ERIC Educational Resources Information Center
Osman, Magda; Wilkinson, Leonora; Beigi, Mazda; Castaneda, Cristina Sanchez; Jahanshahi, Marjan
2008-01-01
The striatum is considered to mediate some forms of procedural learning. Complex dynamic control (CDC) tasks involve an individual having to make a series of sequential decisions to achieve a specific outcome (e.g. learning to operate and control a car), and they involve procedural learning. The aim of this study was to test the hypothesis that…
Two Procedures for Relaxation as Self-Control in the Treatment of Communication Apprehension
ERIC Educational Resources Information Center
Deffenbacher, Jerry L.; Payne, Dennis M.
1977-01-01
An in vivo procedure for relaxation as self-control and a procedure for self-control modification of desensitization were compared to a no-treatment control. Results showed modified desensitization, compared to the control, significantly decreased communication anxiety and fear of negative evaluation and significantly increased assertiveness.…
Procedures for mastitis diagnosis and control.
Sears, P M; González, R N; Wilson, D J; Han, H R
1993-11-01
Procedures for mastitis diagnosis and control include culturing individual cow and bulk tank milk samples, antibiotic susceptibility testing, and evaluation of somatic cell count reports and clinical mastitis treatment records. Integrated use of such procedures is necessary for effective mastitis diagnosis and control.
17 CFR 240.15d-15 - Controls and procedures.
Code of Federal Regulations, 2011 CFR
2011-04-01
... control framework that is established by a body or group that has followed due-process procedures..., without limitation, controls and procedures designed to ensure that information required to be disclosed... disclosure. (f) The term internal control over financial reporting is defined as a process designed by, or...
17 CFR 240.15d-15 - Controls and procedures.
Code of Federal Regulations, 2010 CFR
2010-04-01
... control framework that is established by a body or group that has followed due-process procedures..., without limitation, controls and procedures designed to ensure that information required to be disclosed... disclosure. (f) The term internal control over financial reporting is defined as a process designed by, or...
48 CFR 1301.304 - Agency control and compliance procedures.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Agency control and compliance procedures. 1301.304 Section 1301.304 Federal Acquisition Regulations System DEPARTMENT OF....304 Agency control and compliance procedures. Operating unit counsel shall limit issuance of...
PDSS configuration control plan and procedures
NASA Technical Reports Server (NTRS)
1983-01-01
The payload development support system (PDSS) configuration control plan and procedures are presented. These plans and procedures establish the process for maintaining configuration control of the PDSS system, especially the Spacelab experiment interface device's (SEID) RAU, HRM, and PDI interface simulations and the PDSS ECOS DEP Services simulation. The plans and procedures as specified are designed to provide a simplified but complete configuration control process. The intent is to require a minimum amount of paperwork but provide total traceability of PDSS during experiment test activities.
Pain Management for Gynecologic Procedures in the Office.
Ireland, Luu Doan; Allen, Rebecca H
2016-02-01
Satisfactory pain control for women undergoing office gynecologic procedures is critical for both patient comfort and procedure success. Therefore, it is important for clinicians to be aware of the safety and efficacy of different pain control regimens. This article aimed to review the literature regarding pain control regimens for procedures such as endometrial biopsy, intrauterine device insertion, colposcopy and loop electrosurgical excisional procedure, uterine aspiration, and hysteroscopy. A search of published literature using PubMed was conducted using the following keywords: "pain" or "anesthesia." These terms were paired with the following keywords: "intrauterine device" or "IUD," "endometrial biopsy," "uterine aspiration" or "abortion," "colposcopy" or "loop electrosurgical excisional procedure" or "LEEP," "hysteroscopy" or "hysteroscopic sterilization." The search was conducted through July 2015. Articles were hand reviewed and selected by the authors for study quality. Meta-analyses and randomized controlled trials were prioritized. Although local anesthesia is commonly used for gynecologic procedures, a multimodal approach may be more effective including oral medication, a dedicated emotional support person, and visual or auditory distraction. Women who are nulliparous, are postmenopausal, have a history of dysmenorrhea, or suffer from anxiety are more likely to experience greater pain with gynecologic procedures. Evidence for some interventions exists; however, the interpretation of intervention comparisons is limited by the use of different regimens, pain measurement scales, patient populations, and procedure techniques. There are many options for pain management for office gynecologic procedures, and depending on the procedure, different modalities may work best. The importance of patient counseling and selection cannot be overstated.
40 CFR 136.7 - Quality assurance and quality control.
Code of Federal Regulations, 2014 CFR
2014-07-01
... quality control elements, where applicable, into the laboratory's documented standard operating procedure... quality control elements must be clearly documented in the written standard operating procedure for each... Methods contains QA/QC procedures in the Part 1000 section of the Standard Methods Compendium. The...
40 CFR 136.7 - Quality assurance and quality control.
Code of Federal Regulations, 2013 CFR
2013-07-01
... quality control elements, where applicable, into the laboratory's documented standard operating procedure... quality control elements must be clearly documented in the written standard operating procedure for each... Methods contains QA/QC procedures in the Part 1000 section of the Standard Methods Compendium. The...
40 CFR 136.7 - Quality assurance and quality control.
Code of Federal Regulations, 2012 CFR
2012-07-01
... quality control elements, where applicable, into the laboratory's documented standard operating procedure... quality control elements must be clearly documented in the written standard operating procedure for each... Methods contains QA/QC procedures in the Part 1000 section of the Standard Methods Compendium. The...
Applications of self-control procedures by children: a review.
O'Leary, S G; Dubey, D R
1979-01-01
Self-control procedures as used by children to affect their own behavior were reviewed. Particular emphasis was placed on self-instruction, self-determined criteria, self-assessment, and self-reinforcement. Self-punishment, comprehensive programs, and innovative self-control procedures (distraction and restatement of contingencies) were also evaluated. Basic effectiveness, comparisons with similar externally imposed interventions, maintenance, and the augmental value of the procedures were assessed. Important problems for future research were identified. PMID:389917
Preference for Modes of Dispute Resolution as a Function of Process and Decision Control
ERIC Educational Resources Information Center
Houlden, Pauline; And Others
1978-01-01
Research on procedural justice has suggested that the distribution of control among participants can be used to classify dispute-resolution procedures and may be an important determinant of preference for such procedures. This experiment demonstrates that control can be meaningfully divided into two components: control over the presentation of…
Increasingly automated procedure acquisition in dynamic systems
NASA Technical Reports Server (NTRS)
Mathe, Nathalie; Kedar, Smadar
1992-01-01
Procedures are widely used by operators for controlling complex dynamic systems. Currently, most development of such procedures is done manually, consuming a large amount of paper, time, and manpower in the process. While automated knowledge acquisition is an active field of research, not much attention has been paid to the problem of computer-assisted acquisition and refinement of complex procedures for dynamic systems. The Procedure Acquisition for Reactive Control Assistant (PARC), which is designed to assist users in more systematically and automatically encoding and refining complex procedures. PARC is able to elicit knowledge interactively from the user during operation of the dynamic system. We categorize procedure refinement into two stages: diagnosis - diagnose the failure and choose a repair - and repair - plan and perform the repair. The basic approach taken in PARC is to assist the user in all steps of this process by providing increased levels of assistance with layered tools. We illustrate the operation of PARC in refining procedures for the control of a robot arm.
Autoshaping, random control, and omission training in the rat1
Locurto, Charles; Terrace, H. S.; Gibbon, John
1976-01-01
The role of the stimulus-reinforcer contingency in the development and maintenance of lever contact responding was studied in hooded rats. In Experiment I, three groups of experimentally naive rats were trained either on autoshaping, omission training, or a random-control procedure. Subjects trained by the autoshaping procedure responded more consistently than did either random-control or omission-trained subjects. The probability of at least one lever contact per trial was slightly higher in subjects trained by the omission procedure than by the random-control procedure. However, these differences were not maintained during extended training, nor were they evident in total lever-contact frequencies. When omission and random-control subjects were switched to the autoshaping condition, lever contacts increased in all animals, but a pronounced retardation was observed in omission subjects relative to the random-control subjects. In addition, subjects originally exposed to the random-control procedure, and later switched to autoshaping, acquired more rapidly than naive subjects that were exposed only on the autoshaping procedure. In Experiment II, subjects originally trained by an autoshaping procedure were exposed either to an omission, a random-control, or an extinction procedure. No differences were observed among the groups either in the rate at which lever contacts decreased or in the frequency of lever contacts at the end of training. These data implicate prior experience in the interpretation of omission-training effects and suggest limitations in the influence of stimulus-reinforcer relations in autoshaping. PMID:16811960
Autoshaping, random control, and omission training in the rat.
Locurto, C; Terrace, H S; Gibbon, J
1976-11-01
The role of the stimulus-reinforcer contingency in the development and maintenance of lever contact responding was studied in hooded rats. In Experiment I, three groups of experimentally naive rats were trained either on autoshaping, omission training, or a random-control procedure. Subjects trained by the autoshaping procedure responded more consistently than did either random-control or omission-trained subjects. The probability of at least one lever contact per trial was slightly higher in subjects trained by the omission procedure than by the random-control procedure. However, these differences were not maintained during extended training, nor were they evident in total lever-contact frequencies. When omission and random-control subjects were switched to the autoshaping condition, lever contacts increased in all animals, but a pronounced retardation was observed in omission subjects relative to the random-control subjects. In addition, subjects originally exposed to the random-control procedure, and later switched to autoshaping, acquired more rapidly than naive subjects that were exposed only on the autoshaping procedure. In Experiment II, subjects originally trained by an autoshaping procedure were exposed either to an omission, a random-control, or an extinction procedure. No differences were observed among the groups either in the rate at which lever contacts decreased or in the frequency of lever contacts at the end of training. These data implicate prior experience in the interpretation of omission-training effects and suggest limitations in the influence of stimulus-reinforcer relations in autoshaping.
21 CFR 211.100 - Written procedures; deviations.
Code of Federal Regulations, 2012 CFR
2012-04-01
... Process Controls § 211.100 Written procedures; deviations. (a) There shall be written procedures for production and process control designed to assure that the drug products have the identity, strength, quality... approved by the appropriate organizational units and reviewed and approved by the quality control unit. (b...
21 CFR 211.100 - Written procedures; deviations.
Code of Federal Regulations, 2014 CFR
2014-04-01
... Process Controls § 211.100 Written procedures; deviations. (a) There shall be written procedures for production and process control designed to assure that the drug products have the identity, strength, quality... approved by the appropriate organizational units and reviewed and approved by the quality control unit. (b...
21 CFR 211.100 - Written procedures; deviations.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Process Controls § 211.100 Written procedures; deviations. (a) There shall be written procedures for production and process control designed to assure that the drug products have the identity, strength, quality... approved by the appropriate organizational units and reviewed and approved by the quality control unit. (b...
21 CFR 211.100 - Written procedures; deviations.
Code of Federal Regulations, 2013 CFR
2013-04-01
... Process Controls § 211.100 Written procedures; deviations. (a) There shall be written procedures for production and process control designed to assure that the drug products have the identity, strength, quality... approved by the appropriate organizational units and reviewed and approved by the quality control unit. (b...
21 CFR 211.100 - Written procedures; deviations.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Process Controls § 211.100 Written procedures; deviations. (a) There shall be written procedures for production and process control designed to assure that the drug products have the identity, strength, quality... approved by the appropriate organizational units and reviewed and approved by the quality control unit. (b...
NASA Technical Reports Server (NTRS)
Tibbitts, T. W. (Principal Investigator)
1986-01-01
This report includes procedures for ensuring the quality of the environment provided for plant growth in controlled environment facilities. Biologists and engineers may use these procedures for ensuring quality control during experiments or for ensuring quality control in the design of plant growth facilities. Environmental monitoring prior to and during experiments is included in these procedures. Specific recommendations cover control, acquisition, and calibration for sensor types for the separate parameters of radiation (light), temperature, humidity, carbon dioxide, and air movement.
47 CFR 63.04 - Filing procedures for domestic transfer of control applications
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 3 2010-10-01 2010-10-01 false Filing procedures for domestic transfer of... Extensions and Supplements § 63.04 Filing procedures for domestic transfer of control applications (a) Domestic services only. A carrier seeking domestic section 214 authorization for transfer of control should...
In-Trail Procedure Air Traffic Control Procedures Validation Simulation Study
NASA Technical Reports Server (NTRS)
Chartrand, Ryan C.; Hewitt, Katrin P.; Sweeney, Peter B.; Graff, Thomas J.; Jones, Kenneth M.
2012-01-01
In August 2007, Airservices Australia (Airservices) and the United States National Aeronautics and Space Administration (NASA) conducted a validation experiment of the air traffic control (ATC) procedures associated with the Automatic Dependant Surveillance-Broadcast (ADS-B) In-Trail Procedure (ITP). ITP is an Airborne Traffic Situation Awareness (ATSA) application designed for near-term use in procedural airspace in which ADS-B data are used to facilitate climb and descent maneuvers. NASA and Airservices conducted the experiment in Airservices simulator in Melbourne, Australia. Twelve current operational air traffic controllers participated in the experiment, which identified aspects of the ITP that could be improved (mainly in the communication and controller approval process). Results showed that controllers viewed the ITP as valid and acceptable. This paper describes the experiment design and results.
Hu, Pei-Hsin; Peng, Yen-Chun; Lin, Yu-Ting; Chang, Chi-Sen; Ou, Ming-Chiu
2010-01-01
Colonoscopy is generally tolerated, some patients regarding the procedure as unpleasant and painful and generally performed with the patient sedated and receiving analgesics. The effect of sedation and analgesia for colonoscopy is limited. Aromatherapy is also applied to gastrointestinal endoscopy to reduce procedural anxiety. There is lack of information about aromatherapy specific for colonoscopy. In this study, we aimed to performed a randomized controlled study to investigate the effect of aromatherapy on relieve anxiety, stress and physiological parameters of colonoscopy. A randomized controlled trail was carried out and collected in 2009 and 2010. The participants were randomized in two groups. Aromatherapy was then carried out by inhalation of Sunflower oil (control group) and Neroli oil (Experimental group). The anxiety index was evaluated by State Trait Anxiety Inventory-state (STAI-S) score before aromatherapy and after colonoscopy as well as the pain index for post-procedural by visual analogue scale (VAS). Physiological indicators, such as blood pressure (systolic and diastolic blood pressure), heart rate and respiratory rate were evaluated before and after aromatherapy. Participates in this study were 27 subjects, 13 in control group and 14 in Neroli group with average age 52.26 +/- 17.79 years. There was no significance of procedural anxiety by STAI-S score and procedural pain by VAS. The physiological parameters showed a significant lower pre- and post-procedural systolic blood pressure in Neroli group than control group. Aromatic care for colonoscopy, although with no significant effect on procedural anxiety, is an inexpensive, effective and safe pre-procedural technique that could decrease systolic blood pressure.
A Rejection Principle for Sequential Tests of Multiple Hypotheses Controlling Familywise Error Rates
BARTROFF, JAY; SONG, JINLIN
2015-01-01
We present a unifying approach to multiple testing procedures for sequential (or streaming) data by giving sufficient conditions for a sequential multiple testing procedure to control the familywise error rate (FWER). Together we call these conditions a “rejection principle for sequential tests,” which we then apply to some existing sequential multiple testing procedures to give simplified understanding of their FWER control. Next the principle is applied to derive two new sequential multiple testing procedures with provable FWER control, one for testing hypotheses in order and another for closed testing. Examples of these new procedures are given by applying them to a chromosome aberration data set and to finding the maximum safe dose of a treatment. PMID:26985125
Stepaniak, Pieter S; Vrijland, Wietske W; de Quelerij, Marcel; de Vries, Guus; Heij, Christiaan
2010-12-01
If variation in procedure times could be controlled or better predicted, the cost of surgeries could be reduced through improved scheduling of surgical resources. This study on the impact of similar consecutive cases on the turnover, surgical, and procedure times tests the perception that repeating the same manual tasks reduces the duration of these tasks. We hypothesize that when a fixed team works on similar consecutive cases the result will be shorter turnover and procedure duration as well as less variation as compared with the situation without a fixed team. Case-control study. St Franciscus Hospital, a large general teaching hospital in Rotterdam, the Netherlands. Two procedures, inguinal hernia repair and laparoscopic cholecystectomy, were selected and divided across a control group and a study group. Patients were randomly assigned to the study or control group. Preparation time, surgical time, procedure time, and turnover time. For inguinal hernia repair, we found a significantly lower preparation time and 10 minutes less procedure time in the study group, as compared with the control group. Variation in the study group was lower, as compared with the control group. For laparoscopic cholecystectomy, preparation time was significantly lower in the study group, as compared with the control group. For both procedures, there was a significant decrease in turnover time. Scheduling similar consecutive cases and performing with a fixed team results in lower turnover times and preparation times. The procedure time of the inguinal hernia repair decreased significantly and has practical scheduling implications. For more complex surgery, like laparoscopic cholecystectomy, there is no effect on procedure time.
Sienkiewicz, Edyta; Albrecht, Piotr; Ziółkowski, Janusz; Dziechciarz, Piotr
2015-11-01
In paediatric patients, esophagogastroduodenoscopy (EGD) is commonly performed with the use of sedation. The aim of the study was to compare the effectiveness of propofol and midazolam in providing procedural amnesia and controlling behaviour in children undergoing diagnostic EGD. Children (9-16 years), classified to the first or second class of the American Society of Anaesthesiologists' physical status classification referred for EGD, were randomly assigned to receive propofol with alfentanyl or midazolam with alfentanyl for sedation during the procedure. Within 120 min after the procedure, patients were repeatedly investigated for memory of the procedure and for memory of pain intensity during EGD with the use of the visual analogue scale. Activity and cooperation of the patient during the procedure was assessed with the relative adequacy scale. Of the 51 children, 48 completed the study. Propofol was significantly better than midazolam in inducing amnesia of procedural pain (mean difference 11.53 mm; 95 % confidence interval [CI] 0.96 to 22.10), loss of memory of the procedure (relative risk 0.4; 95 % CI 0.21 to 0.59) and controlling behaviour (relative risk 2.12; 95 % CI 1.33 to 3.36). In children sedated for EGD, propofol is significantly better than midazolam at providing procedural amnesia and controlling behaviour during the procedure.
ERIC Educational Resources Information Center
West, Alfred W.
This is the third in a series of documents developed by the National Training and Operational Technology Center describing operational control procedures for the activated sludge process used in wastewater treatment. This document deals with the calculation procedures associated with a step-feed process. Illustrations and examples are included to…
Candidate CDTI procedures study
NASA Technical Reports Server (NTRS)
Ace, R. E.
1981-01-01
A concept with potential for increasing airspace capacity by involving the pilot in the separation control loop is discussed. Some candidate options are presented. Both enroute and terminal area procedures are considered and, in many cases, a technologically advanced Air Traffic Control structure is assumed. Minimum display characteristics recommended for each of the described procedures are presented. Recommended sequencing of the operational testing of each of the candidate procedures is presented.
12 CFR 1233.4 - Internal controls, policies, procedures, and training.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 12 Banks and Banking 7 2011-01-01 2011-01-01 false Internal controls, policies, procedures, and training. 1233.4 Section 1233.4 Banks and Banking FEDERAL HOUSING FINANCE AGENCY ENTITY REGULATIONS REPORTING OF FRAUDULENT FINANCIAL INSTRUMENTS § 1233.4 Internal controls, policies, procedures, and training. (a) In general. Each regulated entity...
12 CFR 1233.4 - Internal controls, policies, procedures, and training.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 12 Banks and Banking 9 2013-01-01 2013-01-01 false Internal controls, policies, procedures, and training. 1233.4 Section 1233.4 Banks and Banking FEDERAL HOUSING FINANCE AGENCY ENTITY REGULATIONS REPORTING OF FRAUDULENT FINANCIAL INSTRUMENTS § 1233.4 Internal controls, policies, procedures, and training. (a) In general. Each regulated entity...
12 CFR 1233.4 - Internal controls, policies, procedures, and training.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 12 Banks and Banking 10 2014-01-01 2014-01-01 false Internal controls, policies, procedures, and training. 1233.4 Section 1233.4 Banks and Banking FEDERAL HOUSING FINANCE AGENCY ENTITY REGULATIONS REPORTING OF FRAUDULENT FINANCIAL INSTRUMENTS § 1233.4 Internal controls, policies, procedures, and training. (a) In general. Each regulated entity...
12 CFR 1233.4 - Internal controls, policies, procedures, and training.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 12 Banks and Banking 9 2012-01-01 2012-01-01 false Internal controls, policies, procedures, and training. 1233.4 Section 1233.4 Banks and Banking FEDERAL HOUSING FINANCE AGENCY ENTITY REGULATIONS REPORTING OF FRAUDULENT FINANCIAL INSTRUMENTS § 1233.4 Internal controls, policies, procedures, and training. (a) In general. Each regulated entity...
12 CFR 1731.5 - Internal controls, procedures, and training.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Internal controls, procedures, and training. 1731.5 Section 1731.5 Banks and Banking OFFICE OF FEDERAL HOUSING ENTERPRISE OVERSIGHT, DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT SAFETY AND SOUNDNESS MORTGAGE FRAUD REPORTING § 1731.5 Internal controls, procedures, and training. An Enterprise shall...
48 CFR 801.304 - Department control and compliance procedures.
Code of Federal Regulations, 2010 CFR
2010-10-01
... compliance procedures. 801.304 Section 801.304 Federal Acquisition Regulations System DEPARTMENT OF VETERANS... Regulations 801.304 Department control and compliance procedures. The Assistant Secretary for Management is... responsible for amending the VAAR for compliance with FAR 1.304. ...
López-Gastey, J; Choucri, A; Robidoux, P Y; Sunahara, G I
2000-06-01
An innovative screening procedure has been developed to detect illicit toxic discharges in domestic septic tank sludge hauled to the Montreal Urban Community waste-water treatment plant. This new means of control is based on an integrative approach, using bioassays and chemical analyses. Conservative criteria are applied to detect abnormal toxicity with great reliability while avoiding false positive results. The complementary data obtained from toxicity tests and chemical analyses support the use of this efficient and easy-to-apply procedure. This study assesses the control procedure in which 231 samples were analyzed over a 30-month period. Data clearly demonstrate the deterrent power of an efficient control procedure combined with a public awareness campaign among the carriers. In the first 15 months of application, between January 1996 and March 1997, approximately 30% of the 123 samples analyzed showed abnormal toxicity. Between April 1997 and June 1998, that is, after a public hearing presentation of this procedure, this proportion dropped significantly to approximately 9% based on 108 analyzed samples. The results of a 30-month application of this new control procedure show the superior efficiency of the ecotoxicological approach compared with the previously used chemical control procedure. To be able to apply it effectively and, if necessary, to apply the appropriate coercive measures, ecotoxicological criteria should be included in regulatory guidelines.
NASA Technical Reports Server (NTRS)
Nissim, E.; Abel, I.
1978-01-01
An optimization procedure is developed based on the responses of a system to continuous gust inputs. The procedure uses control law transfer functions which have been partially determined by using the relaxed aerodynamic energy approach. The optimization procedure yields a flutter suppression system which minimizes control surface activity in a gust environment. The procedure is applied to wing flutter of a drone aircraft to demonstrate a 44 percent increase in the basic wing flutter dynamic pressure. It is shown that a trailing edge control system suppresses the flutter instability over a wide range of subsonic mach numbers and flight altitudes. Results of this study confirm the effectiveness of the relaxed energy approach.
48 CFR 2801.304 - Agency control and compliance procedures.
Code of Federal Regulations, 2010 CFR
2010-10-01
... compliance procedures. 2801.304 Section 2801.304 Federal Acquisition Regulations System DEPARTMENT OF JUSTICE General DEPARTMENT OF JUSTICE ACQUISITION REGULATIONS SYSTEM Agency Acquisition Regulations 2801.304 Agency control and compliance procedures. Pursuant to FAR 1.304, the Procurement Executive (PE) is...
ERIC Educational Resources Information Center
Boyd, Aimee M.; Dodd, Barbara; Fitzpatrick, Steven
2013-01-01
This study compared several exposure control procedures for CAT systems based on the three-parameter logistic testlet response theory model (Wang, Bradlow, & Wainer, 2002) and Masters' (1982) partial credit model when applied to a pool consisting entirely of testlets. The exposure control procedures studied were the modified within 0.10 logits…
More than just tapping: index finger-tapping measures procedural learning in schizophrenia.
Da Silva, Felipe N; Irani, Farzin; Richard, Jan; Brensinger, Colleen M; Bilker, Warren B; Gur, Raquel E; Gur, Ruben C
2012-05-01
Finger-tapping has been widely studied using behavioral and neuroimaging paradigms. Evidence supports the use of finger-tapping as an endophenotype in schizophrenia, but its relationship with motor procedural learning remains unexplored. To our knowledge, this study presents the first use of index finger-tapping to study procedural learning in individuals with schizophrenia or schizoaffective disorder (SCZ/SZA) as compared to healthy controls. A computerized index finger-tapping test was administered to 1169 SCZ/SZA patients (62% male, 88% right-handed), and 689 healthy controls (40% male, 93% right-handed). Number of taps per trial and learning slopes across trials for the dominant and non-dominant hands were examined for motor speed and procedural learning, respectively. Both healthy controls and SCZ/SZA patients demonstrated procedural learning for their dominant hand but not for their non-dominant hand. In addition, patients showed a greater capacity for procedural learning even though they demonstrated more variability in procedural learning compared to healthy controls. Left-handers of both groups performed better than right-handers and had less variability in mean number of taps between non-dominant and dominant hands. Males also had less variability in mean tap count between dominant and non-dominant hands than females. As expected, patients had a lower mean number of taps than healthy controls, males outperformed females and dominant-hand trials had more mean taps than non-dominant hand trials in both groups. The index finger-tapping test can measure both motor speed and procedural learning, and motor procedural learning may be intact in SCZ/SZA patients. Copyright © 2012 Elsevier B.V. All rights reserved.
Code of Federal Regulations, 2014 CFR
2014-01-01
..., implement, and maintain written standard operating procedures for each assay performed for drug and specimen... facility shall develop, implement, and maintain written standard operating procedures for each test. The...; (2) Preparation of reagents, standards, and controls; (3) Calibration procedures; (4) Derivation of...
Code of Federal Regulations, 2012 CFR
2012-01-01
..., implement, and maintain written standard operating procedures for each assay performed for drug and specimen... facility shall develop, implement, and maintain written standard operating procedures for each test. The...; (2) Preparation of reagents, standards, and controls; (3) Calibration procedures; (4) Derivation of...
Code of Federal Regulations, 2013 CFR
2013-01-01
..., implement, and maintain written standard operating procedures for each assay performed for drug and specimen... facility shall develop, implement, and maintain written standard operating procedures for each test. The...; (2) Preparation of reagents, standards, and controls; (3) Calibration procedures; (4) Derivation of...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Procedures. 592.701 Section 592.701 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY ROUGH DIAMONDS CONTROL REGULATIONS Procedures § 592.701...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 31 Money and Finance:Treasury 3 2012-07-01 2012-07-01 false Procedures. 592.701 Section 592.701 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY ROUGH DIAMONDS CONTROL REGULATIONS Procedures § 592.701...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 31 Money and Finance:Treasury 3 2011-07-01 2011-07-01 false Procedures. 592.701 Section 592.701 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY ROUGH DIAMONDS CONTROL REGULATIONS Procedures § 592.701...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 31 Money and Finance:Treasury 3 2013-07-01 2013-07-01 false Procedures. 592.701 Section 592.701 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY ROUGH DIAMONDS CONTROL REGULATIONS Procedures § 592.701...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 31 Money and Finance:Treasury 3 2014-07-01 2014-07-01 false Procedures. 592.701 Section 592.701 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY ROUGH DIAMONDS CONTROL REGULATIONS Procedures § 592.701...
77 FR 56698 - Air Traffic Procedures Advisory Committee
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-13
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Air Traffic Procedures Advisory... advise the public that a meeting of the Federal Aviation Administration Air Traffic Procedures Advisory Committee (ATPAC) will be held to review present air traffic control procedures and practices for...
76 FR 27168 - Air Traffic Procedures Advisory Committee
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-10
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Air Traffic Procedures Advisory... advise the public that a meeting of the Federal Aviation Administration Air Traffic Procedures Advisory Committee (ATPAC) will be held to review present air traffic control procedures and practices for...
75 FR 22892 - Air Traffic Procedures Advisory Committee
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-30
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Air Traffic Procedures Advisory... advise the public that a meeting of the Federal Aviation Administration Air Traffic Procedures Advisory Committee (ATPAC) will be held to review present air traffic control procedures and practices for...
78 FR 2711 - Air Traffic Procedures Advisory Committee
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-14
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Air Traffic Procedures Advisory... advise the public that a meeting of the Federal Aviation Administration Air Traffic Procedures Advisory Committee (ATPAC) will be held to review present air traffic control procedures and practices for...
76 FR 59481 - Air Traffic Procedures Advisory Committee
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-26
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Air Traffic Procedures Advisory... advise the public that a meeting of the Federal Aviation Administration Air Traffic Procedures Advisory Committee (ATPAC) will be held to review present air traffic control procedures and practices for...
77 FR 27835 - Air Traffic Procedures Advisory Committee
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-11
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Air Traffic Procedures Advisory... advise the public that a meeting of the Federal Aviation Administration Air Traffic Procedures Advisory Committee (ATPAC) will be held to review present air traffic control procedures and practices for...
77 FR 2603 - Air Traffic Procedures Advisory Committee
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-18
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Air Traffic Procedures Advisory... advise the public that a meeting of the Federal Aviation Administration Air Traffic Procedures Advisory Committee (ATPAC) will be held to review present air traffic control procedures and practices for...
77 FR 67862 - Air Traffic Procedures Advisory Committee
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-14
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Air Traffic Procedures Advisory... advise the public that the FAA's Air Traffic Procedures Advisory Committee (ATPAC) two year charter has... provides a venue to review air traffic control procedures and practices for standardization, revision...
40 CFR 1066.10 - Other procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Other procedures. 1066.10 Section 1066.10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Applicability and General Provisions § 1066.10 Other procedures. (a) Your...
40 CFR 1066.10 - Other procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Other procedures. 1066.10 Section 1066.10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Applicability and General Provisions § 1066.10 Other procedures. (a) Your...
40 CFR 1066.10 - Other procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Other procedures. 1066.10 Section 1066.10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Applicability and General Provisions § 1066.10 Other procedures. (a) Your...
Chronic relapsing pancreatitis in a child. Use of the Puestow procedure to achieve ductal drainage.
Duncan, N D; McDonald, A; James, M; Brown, B; Mitchell, D I
2000-09-01
A case of chronic relapsing pancreatitis presenting in an 8-year-old African Jamaican girl is outlined. Aggressive supportive management failed to control pain and vomiting. The Puestow Procedure effectively procedure aborted these symptoms. The use of the Puestow procedure should not be inordinately delayed in chronic relapsing pancreatitis if symptoms persist, since it may not only control pain but also halt declining pancreatic function.
23 CFR 655.605 - Project procedures.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 23 Highways 1 2010-04-01 2010-04-01 false Project procedures. 655.605 Section 655.605 Highways... OPERATIONS Traffic Control Devices on Federal-Aid and Other Streets and Highways § 655.605 Project procedures. (a) Federal-aid highways. Federal-aid projects involving the installation of traffic control devices...
23 CFR 655.605 - Project procedures.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 23 Highways 1 2012-04-01 2012-04-01 false Project procedures. 655.605 Section 655.605 Highways... OPERATIONS Traffic Control Devices on Federal-Aid and Other Streets and Highways § 655.605 Project procedures. (a) Federal-aid highways. Federal-aid projects involving the installation of traffic control devices...
23 CFR 655.605 - Project procedures.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 23 Highways 1 2014-04-01 2014-04-01 false Project procedures. 655.605 Section 655.605 Highways... OPERATIONS Traffic Control Devices on Federal-Aid and Other Streets and Highways § 655.605 Project procedures. (a) Federal-aid highways. Federal-aid projects involving the installation of traffic control devices...
23 CFR 655.605 - Project procedures.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 23 Highways 1 2011-04-01 2011-04-01 false Project procedures. 655.605 Section 655.605 Highways... OPERATIONS Traffic Control Devices on Federal-Aid and Other Streets and Highways § 655.605 Project procedures. (a) Federal-aid highways. Federal-aid projects involving the installation of traffic control devices...
23 CFR 655.605 - Project procedures.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 23 Highways 1 2013-04-01 2013-04-01 false Project procedures. 655.605 Section 655.605 Highways... OPERATIONS Traffic Control Devices on Federal-Aid and Other Streets and Highways § 655.605 Project procedures. (a) Federal-aid highways. Federal-aid projects involving the installation of traffic control devices...
Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.
2009-01-01
The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance and quality-control data were stored in the laboratory's Lab Master data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality control samples analyzed from July 2001 through June 2003. Results for the quality-control samples for 19 analytical procedures were evaluated for bias and precision. Control charts indicate that data for six of the analytical procedures were occasionally biased for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, chloride, magnesium, nitrate (ion chromatography), potassium, and sodium. The calcium procedure was biased throughout the analysis period for the high-concentration sample, but was within control limits. The total monomeric aluminum and fluoride procedures were biased throughout the analysis period for the low-concentration sample, but were within control limits. The total aluminum, pH, specific conductance, and sulfate procedures were biased for the high-concentration and low-concentration samples, but were within control limits. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 16 of 18 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. The data-quality objective was not met for the dissolved organic carbon or specific conductance procedures. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 18 of the 21 analytes. At least 90 percent of the samples met data-quality objectives for all procedures except total monomeric aluminum (83 percent of samples met objectives), total aluminum (76 percent of samples met objectives), ammonium (73 percent of samples met objectives), dissolved organic carbon (86 percent of samples met objectives), and nitrate (81 percent of samples met objectives). The data-quality objective was not met for the nitrite procedure. Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated satisfactory or above data quality over the time period, with most performance ratings for each sample in the good-to-excellent range. The N-sample (nutrient constituents) analysis had one unsatisfactory rating for the ammonium procedure in one study. The T-sample (trace constituents) analysis had one unsatisfactory rating for the magnesium procedure and one marginal rating for the potassium procedure in one study and one unsatisfactory rating for the sodium procedure in another. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 90 percent of the samples met data-quality objectives for 10 of the 14 analytes; the exceptions were acid-neutralizing capacity, ammonium, dissolved organic carbon, and sodium. Data-quality objectives were not met in 37 percent of samples analyzed for acid-neutralizing capacity, 28 percent of samples analyzed for dissolved organic carbon, and 30 percent of samples analyzed for sodium. Results indicate a positive bias for the ammonium procedure in one study and a negative bias in another. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 90 percent of the samples analyzed for calcium, chloride, magnesium, pH, potassium, and sodium. Data-quality objectives were met by 78 percent of
A field test of procedures for evaluating and scheduling white-pine weevil control
Robert P. Ford; Robert L. Talerico; D. Gordon Mott
1965-01-01
Procedures have recently been developed that permit economic and biological information to be integrated in making decisions about the need for control against the white-pine weevil, and in scheduling control in young white pine plantations. The procedures are based upon studies of the magnitude of economic losses that result from weevil attack in white pine and upon...
A method of automatic control procedures cardiopulmonary resuscitation
NASA Astrophysics Data System (ADS)
Bureev, A. Sh.; Zhdanov, D. S.; Kiseleva, E. Yu.; Kutsov, M. S.; Trifonov, A. Yu.
2015-11-01
The study is to present the results of works on creation of methods of automatic control procedures of cardiopulmonary resuscitation (CPR). A method of automatic control procedure of CPR by evaluating the acoustic data of the dynamics of blood flow in the bifurcation of carotid arteries and the dynamics of air flow in a trachea according to the current guidelines for CPR is presented. Evaluation of the patient is carried out by analyzing the respiratory noise and blood flow in the interspaces between the chest compressions and artificial pulmonary ventilation. The device operation algorithm of automatic control procedures of CPR and its block diagram has been developed.
Design of controlled elastic and inelastic structures
NASA Astrophysics Data System (ADS)
Reinhorn, A. M.; Lavan, O.; Cimellaro, G. P.
2009-12-01
One of the founders of structural control theory and its application in civil engineering, Professor Emeritus Tsu T. Soong, envisioned the development of the integral design of structures protected by active control devices. Most of his disciples and colleagues continuously attempted to develop procedures to achieve such integral control. In his recent papers published jointly with some of the authors of this paper, Professor Soong developed design procedures for the entire structure using a design — redesign procedure applied to elastic systems. Such a procedure was developed as an extension of other work by his disciples. This paper summarizes some recent techniques that use traditional active control algorithms to derive the most suitable (optimal, stable) control force, which could then be implemented with a combination of active, passive and semi-active devices through a simple match or more sophisticated optimal procedures. Alternative design can address the behavior of structures using Liapunov stability criteria. This paper shows a unified procedure which can be applied to both elastic and inelastic structures. Although the implementation does not always preserve the optimal criteria, it is shown that the solutions are effective and practical for design of supplemental damping, stiffness enhancement or softening, and strengthening or weakening.
75 FR 63255 - Air Traffic Procedures Advisory Committee Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-14
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Air Traffic Procedures Advisory... notice to advise the public that a meeting of the Federal Aviation Administration Air Traffic Procedures Advisory Committee (ATPAC) will be held to review present air traffic control procedures and practices for...
78 FR 66098 - Air Traffic Procedures Advisory Committee
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-04
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Air Traffic Procedures Advisory... issuing this notice to advise the public that a meeting of the Federal Aviation Administration Air Traffic Procedures Advisory Committee (ATPAC) will be held to review present air traffic control procedures and...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-28
... procedure for determining the energy consumption of electric refrigerators and refrigerator-freezers. The... condensation. The existing test procedure does not take humidity or adaptive control technology into account. Therefore, Electrolux has suggested an alternate test procedure that takes adaptive control technology into...
40 CFR 1037.550 - Special procedures for testing post-transmission hybrid systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... This section describes the procedure for simulating a chassis test with a post-transmission hybrid... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Special procedures for testing post... AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW HEAVY-DUTY MOTOR VEHICLES Test...
ERIC Educational Resources Information Center
Sloan, Garry
This curriculum guide, one of six modules keyed to the building maintenance competency profile developed by industry and education professionals, provides materials for two units on electrical procedures and environmental control systems. Unit 1, on electrical procedures, includes the following lessons: electrical safety; troubleshooting and…
40 CFR 1066.235 - Speed verification procedure.
Code of Federal Regulations, 2012 CFR
2012-07-01
... before testing, and after major maintenance. (c) Procedure. Use one of the following procedures to verify... dynamometer control circuits. Determine the speed error as follows: (i) Set the dynamometer to speed-control mode. Set the dynamometer speed to a value between 4.2 m/s and the maximum speed expected during...
The NASA Constellation Program Procedure System
NASA Technical Reports Server (NTRS)
Phillips, Robert G.; Wang, Lui
2010-01-01
NASA has used procedures to describe activities to be performed onboard vehicles by astronaut crew and on the ground by flight controllers since Apollo. Starting with later Space Shuttle missions and the International Space Station, NASA moved forward to electronic presentation of procedures. For the Constellation Program, another large step forward is being taken - to make procedures more interactive with the vehicle and to assist the crew in controlling the vehicle more efficiently and with less error. The overall name for the project is the Constellation Procedure Applications Software System (CxPASS). This paper describes some of the history behind this effort, the key concepts and operational paradigms that the work is based upon, and the actual products being developed to implement procedures for Constellation
Representing operations procedures using temporal dependency networks
NASA Technical Reports Server (NTRS)
Fayyad, Kristina E.; Cooper, Lynne P.
1993-01-01
DSN Link Monitor & Control (LMC) operations consist primarily of executing procedures to configure, calibrate, test, and operate a communications link between an interplanetary spacecraft and its mission control center. Currently the LMC operators are responsible for integrating procedures into an end-to-end series of steps. The research presented in this paper is investigating new ways of specifying operations procedures that incorporate the insight of operations, engineering, and science personnel to improve mission operations. The paper describes the rationale for using Temporal Dependency Networks (TDN's) to represent the procedures, a description of how the data is acquired, and the knowledge engineering effort required to represent operations procedures. Results of operational tests of this concept, as implemented in the LMC Operator Assistant Prototype (LMCOA), are also presented.
A compendium of controlled diffusion blades generated by an automated inverse design procedure
NASA Technical Reports Server (NTRS)
Sanz, Jose M.
1989-01-01
A set of sample cases was produced to test an automated design procedure developed at the NASA Lewis Research Center for the design of controlled diffusion blades. The range of application of the automated design procedure is documented. The results presented include characteristic compressor and turbine blade sections produced with the automated design code as well as various other airfoils produced with the base design method prior to the incorporation of the automated procedure.
Ultrasound and bronchoscopic controlled percutaneous tracheostomy on trauma ICU.
Kollig, E; Heydenreich, U; Roetman, B; Hopf, F; Muhr, G
2000-11-01
Tracheostomy is a common surgical procedure performed in long-term ventilated patients in intensive care. Since the role of percutaneous dilatational tracheostomy (PDT) on Intensive Care Unit (ICU) has become steadily more important in the last few years, a prospective study was started to evaluate the economic efficiency and to show the minimization of the complication rate of this procedure. In 72 patients we performed PDT as a bedside procedure. Initially the thyroid gland and the subcutaneous vessels were studied by ultrasound in every patient. The puncture of the trachea, the dilatational procedure and the insertion of the tracheal cannula were executed under bronchoscopic monitoring. Finally, a bronchoscopic control view followed via the new cannula to detect intratracheal complications. Mechanical ventilation was maintained during the procedure and controlled by continuous pulse oximetry. According to prior ultrasound findings the place to puncture the trachea was changed in 24% of the patients, in one case tracheostomy was performed as an open conventional procedure. The following complications could be observed: one case involving perforation of a cartilaginous ring, one case with venous bleeding of a small subcutaneous vein and two cases with punctures of the bronchoscope. There were no cases of miscannulation, penetration of the posterior tracheal wall or major bleeding requiring intervention or conversion. The followup study revealed that there was no sign of further complications in any patient. In addition, cost analysis demonstrated that there was a significant economical advantage of PDT in comparison with open standard tracheostomy. Standardized ultrasonographically and bronchoscopically controlled PDT turns out to be a safe, simple and cost effective bedside procedure on ICU. Because of ultrasound examination performed before the procedure, and bronchoscopic surveillance during the procedure, safety of this procedure can be enhanced, thus minimizing the rate of complications.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Judicial Administration DEPARTMENT OF JUSTICE NONDISCRIMINATION; EQUAL EMPLOYMENT OPPORTUNITY; POLICIES AND... Section 504 of the Rehabilitation Act of 1973 Procedures § 42.530 Procedures. (a) The procedural... section 803(a) of title I of the Omnibus Crime Control and Safe Streets Act, as amended by the Justice...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Judicial Administration DEPARTMENT OF JUSTICE NONDISCRIMINATION; EQUAL EMPLOYMENT OPPORTUNITY; POLICIES AND... Section 504 of the Rehabilitation Act of 1973 Procedures § 42.530 Procedures. (a) The procedural... section 803(a) of title I of the Omnibus Crime Control and Safe Streets Act, as amended by the Justice...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Judicial Administration DEPARTMENT OF JUSTICE NONDISCRIMINATION; EQUAL EMPLOYMENT OPPORTUNITY; POLICIES AND... Section 504 of the Rehabilitation Act of 1973 Procedures § 42.530 Procedures. (a) The procedural... section 803(a) of title I of the Omnibus Crime Control and Safe Streets Act, as amended by the Justice...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Judicial Administration DEPARTMENT OF JUSTICE NONDISCRIMINATION; EQUAL EMPLOYMENT OPPORTUNITY; POLICIES AND... Section 504 of the Rehabilitation Act of 1973 Procedures § 42.530 Procedures. (a) The procedural... section 803(a) of title I of the Omnibus Crime Control and Safe Streets Act, as amended by the Justice...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Judicial Administration DEPARTMENT OF JUSTICE NONDISCRIMINATION; EQUAL EMPLOYMENT OPPORTUNITY; POLICIES AND... Section 504 of the Rehabilitation Act of 1973 Procedures § 42.530 Procedures. (a) The procedural... section 803(a) of title I of the Omnibus Crime Control and Safe Streets Act, as amended by the Justice...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Procedures. 546.801 Section 546.801 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY DARFUR SANCTIONS REGULATIONS Procedures § 546.801 Procedures...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 31 Money and Finance:Treasury 3 2011-07-01 2011-07-01 false Procedures. 537.801 Section 537.801 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY BURMESE SANCTIONS REGULATIONS Procedures § 537.801 Procedures...
40 CFR 92.125 - Pre-test procedures and preconditioning.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Pre-test procedures and... PROGRAMS (CONTINUED) CONTROL OF AIR POLLUTION FROM LOCOMOTIVES AND LOCOMOTIVE ENGINES Test Procedures § 92.125 Pre-test procedures and preconditioning. (a) Locomotive testing. (1) Determine engine lubricating...
40 CFR 92.125 - Pre-test procedures and preconditioning.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Pre-test procedures and... PROGRAMS (CONTINUED) CONTROL OF AIR POLLUTION FROM LOCOMOTIVES AND LOCOMOTIVE ENGINES Test Procedures § 92.125 Pre-test procedures and preconditioning. (a) Locomotive testing. (1) Determine engine lubricating...
40 CFR 92.125 - Pre-test procedures and preconditioning.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Pre-test procedures and... PROGRAMS (CONTINUED) CONTROL OF AIR POLLUTION FROM LOCOMOTIVES AND LOCOMOTIVE ENGINES Test Procedures § 92.125 Pre-test procedures and preconditioning. (a) Locomotive testing. (1) Determine engine lubricating...
40 CFR 92.125 - Pre-test procedures and preconditioning.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Pre-test procedures and... PROGRAMS (CONTINUED) CONTROL OF AIR POLLUTION FROM LOCOMOTIVES AND LOCOMOTIVE ENGINES Test Procedures § 92.125 Pre-test procedures and preconditioning. (a) Locomotive testing. (1) Determine engine lubricating...
40 CFR 205.54 - Test procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Test procedures. 205.54 Section 205.54 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT PROGRAMS TRANSPORTATION EQUIPMENT NOISE EMISSION CONTROLS Medium and Heavy Trucks § 205.54 Test procedures. The procedures described...
Technique of Automated Control Over Cardiopulmonary Resuscitation Procedures
NASA Astrophysics Data System (ADS)
Bureev, A. Sh; Kiseleva, E. Yu; Kutsov, M. S.; Zhdanov, D. S.
2016-01-01
The article describes a technique of automated control over cardiopulmonary resuscitation procedures on the basis of acoustic data. The research findings have allowed determining the primary important characteristics of acoustic signals (sounds of blood circulation in the carotid artery and respiratory sounds) and proposing a method to control the performance of resuscitation procedures. This method can be implemented as a part of specialized hardware systems.
14 CFR 135.83 - Operating information required.
Code of Federal Regulations, 2012 CFR
2012-01-01
... the following procedures: (1) Before starting engines; (2) Before takeoff; (3) Cruise; (4) Before... controls. (3) Engine inoperative procedures. (4) Any other emergency procedures necessary for safety. ...
14 CFR 135.83 - Operating information required.
Code of Federal Regulations, 2010 CFR
2010-01-01
... the following procedures: (1) Before starting engines; (2) Before takeoff; (3) Cruise; (4) Before... controls. (3) Engine inoperative procedures. (4) Any other emergency procedures necessary for safety. ...
14 CFR 135.83 - Operating information required.
Code of Federal Regulations, 2014 CFR
2014-01-01
... the following procedures: (1) Before starting engines; (2) Before takeoff; (3) Cruise; (4) Before... controls. (3) Engine inoperative procedures. (4) Any other emergency procedures necessary for safety. ...
14 CFR 135.83 - Operating information required.
Code of Federal Regulations, 2013 CFR
2013-01-01
... the following procedures: (1) Before starting engines; (2) Before takeoff; (3) Cruise; (4) Before... controls. (3) Engine inoperative procedures. (4) Any other emergency procedures necessary for safety. ...
14 CFR 135.83 - Operating information required.
Code of Federal Regulations, 2011 CFR
2011-01-01
... the following procedures: (1) Before starting engines; (2) Before takeoff; (3) Cruise; (4) Before... controls. (3) Engine inoperative procedures. (4) Any other emergency procedures necessary for safety. ...
40 CFR 1065.12 - Approval of alternate procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Applicability and General Provisions § 1065.12 Approval of... individual engine manufacturer may request to use an alternate procedure. This also means that an instrument... allow. (2) The degree to which the alternate procedure affects your ability to show that your engines...
40 CFR 92.125 - Pre-test procedures and preconditioning.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Pre-test procedures and preconditioning... PROGRAMS (CONTINUED) CONTROL OF AIR POLLUTION FROM LOCOMOTIVES AND LOCOMOTIVE ENGINES Test Procedures § 92.125 Pre-test procedures and preconditioning. (a) Locomotive testing. (1) Determine engine lubricating...
Procedures For Microbial-Ecology Laboratory
NASA Technical Reports Server (NTRS)
Huff, Timothy L.
1993-01-01
Microbial Ecology Laboratory Procedures Manual provides concise and well-defined instructions on routine technical procedures to be followed in microbiological laboratory to ensure safety, analytical control, and validity of results.
POWER-ENHANCED MULTIPLE DECISION FUNCTIONS CONTROLLING FAMILY-WISE ERROR AND FALSE DISCOVERY RATES.
Peña, Edsel A; Habiger, Joshua D; Wu, Wensong
2011-02-01
Improved procedures, in terms of smaller missed discovery rates (MDR), for performing multiple hypotheses testing with weak and strong control of the family-wise error rate (FWER) or the false discovery rate (FDR) are developed and studied. The improvement over existing procedures such as the Šidák procedure for FWER control and the Benjamini-Hochberg (BH) procedure for FDR control is achieved by exploiting possible differences in the powers of the individual tests. Results signal the need to take into account the powers of the individual tests and to have multiple hypotheses decision functions which are not limited to simply using the individual p -values, as is the case, for example, with the Šidák, Bonferroni, or BH procedures. They also enhance understanding of the role of the powers of individual tests, or more precisely the receiver operating characteristic (ROC) functions of decision processes, in the search for better multiple hypotheses testing procedures. A decision-theoretic framework is utilized, and through auxiliary randomizers the procedures could be used with discrete or mixed-type data or with rank-based nonparametric tests. This is in contrast to existing p -value based procedures whose theoretical validity is contingent on each of these p -value statistics being stochastically equal to or greater than a standard uniform variable under the null hypothesis. Proposed procedures are relevant in the analysis of high-dimensional "large M , small n " data sets arising in the natural, physical, medical, economic and social sciences, whose generation and creation is accelerated by advances in high-throughput technology, notably, but not limited to, microarray technology.
Standardization of carbon-phenolic composite test methodology
NASA Technical Reports Server (NTRS)
Hall, W. B.
1986-01-01
The objective of this study was to evaluate the residual volatiles, filler content, and resin flow test procedures for carbon-phenolic prepreg materials. The residual volatile test procedure was rewritten with tighter procedure control which was then evaluated by round robin testing by four laboratories on the same rolls of prepreg. Results indicated that the residual volatiles test was too operator and equipment dependent to be reliable, and it was recommended that the test be discontinued. The resin flow test procedures were rewritten with tighter procedure control, and it is now considered to be an acceptable test. It was recommended that the filler content determination be made prior to prepregging.
Microbial ecology laboratory procedures manual NASA/MSFC
NASA Technical Reports Server (NTRS)
Huff, Timothy L.
1990-01-01
An essential part of the efficient operation of any microbiology laboratory involved in sample analysis is a standard procedures manual. The purpose of this manual is to provide concise and well defined instructions on routine technical procedures involving sample analysis and methods for monitoring and maintaining quality control within the laboratory. Of equal importance is the safe operation of the laboratory. This manual outlines detailed procedures to be followed in the microbial ecology laboratory to assure safety, analytical control, and validity of results.
46 CFR 130.480 - Test procedure and operations manual.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Test procedure and operations manual. 130.480 Section... VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.480 Test procedure and operations manual. (a) A procedure for tests to be conducted on automated...
77 FR 32645 - Revision of Performance Standards for State Medicaid Fraud Control Units
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-01
... Procedures A Unit establishes written policies and procedures for its operations and ensures that staff are familiar with, and adhere to, policies and procedures. To determine whether a Unit meets this standard, OIG... contain current policies and procedures, consistent with these performance standards, for the...
40 CFR 94.104 - Test procedures for Category 2 marine engines.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Test procedures for Category 2 marine... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM MARINE COMPRESSION-IGNITION ENGINES Test Procedures § 94.104 Test procedures for Category 2 marine engines. (a) Gaseous and particulate emissions shall be measured...
40 CFR 94.104 - Test procedures for Category 2 marine engines.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Test procedures for Category 2 marine... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM MARINE COMPRESSION-IGNITION ENGINES Test Procedures § 94.104 Test procedures for Category 2 marine engines. (a) Gaseous and particulate emissions shall be measured...
40 CFR 94.103 - Test procedures for Category 1 marine engines.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Test procedures for Category 1 marine... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM MARINE COMPRESSION-IGNITION ENGINES Test Procedures § 94.103 Test procedures for Category 1 marine engines. (a) Gaseous and particulate emissions shall be measured...
40 CFR 94.103 - Test procedures for Category 1 marine engines.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Test procedures for Category 1 marine... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM MARINE COMPRESSION-IGNITION ENGINES Test Procedures § 94.103 Test procedures for Category 1 marine engines. (a) Gaseous and particulate emissions shall be measured...
49 CFR 219.605 - Positive drug test results; procedures.
Code of Federal Regulations, 2012 CFR
2012-10-01
... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Random Alcohol and Drug Testing Programs § 219.605 Positive drug test results; procedures. (a) [Reserved] (b) Procedures for administrative... 49 Transportation 4 2012-10-01 2012-10-01 false Positive drug test results; procedures. 219.605...
49 CFR 219.605 - Positive drug test results; procedures.
Code of Federal Regulations, 2010 CFR
2010-10-01
... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Random Alcohol and Drug Testing Programs § 219.605 Positive drug test results; procedures. (a) [Reserved] (b) Procedures for administrative... 49 Transportation 4 2010-10-01 2010-10-01 false Positive drug test results; procedures. 219.605...
49 CFR 219.605 - Positive drug test results; procedures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Random Alcohol and Drug Testing Programs § 219.605 Positive drug test results; procedures. (a) [Reserved] (b) Procedures for administrative... 49 Transportation 4 2011-10-01 2011-10-01 false Positive drug test results; procedures. 219.605...
49 CFR 219.605 - Positive drug test results; procedures.
Code of Federal Regulations, 2013 CFR
2013-10-01
... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Random Alcohol and Drug Testing Programs § 219.605 Positive drug test results; procedures. (a) [Reserved] (b) Procedures for administrative... 49 Transportation 4 2013-10-01 2013-10-01 false Positive drug test results; procedures. 219.605...
49 CFR 219.605 - Positive drug test results; procedures.
Code of Federal Regulations, 2014 CFR
2014-10-01
... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Random Alcohol and Drug Testing Programs § 219.605 Positive drug test results; procedures. (a) [Reserved] (b) Procedures for administrative... 49 Transportation 4 2014-10-01 2014-10-01 false Positive drug test results; procedures. 219.605...
40 CFR 205.54 - Test procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Test procedures. 205.54 Section 205.54... EQUIPMENT NOISE EMISSION CONTROLS Medium and Heavy Trucks § 205.54 Test procedures. The procedures described in this and subsequent sections will be the test program to determine the conformity of vehicles with...
40 CFR 205.54 - Test procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Test procedures. 205.54 Section 205.54... EQUIPMENT NOISE EMISSION CONTROLS Medium and Heavy Trucks § 205.54 Test procedures. The procedures described in this and subsequent sections will be the test program to determine the conformity of vehicles with...
21 CFR 820.70 - Production and process controls.
Code of Federal Regulations, 2011 CFR
2011-04-01
... process control procedures that describe any process controls necessary to ensure conformance to specifications. Where process controls are needed they shall include: (1) Documented instructions, standard operating procedures (SOP's), and methods that define and control the manner of production; (2) Monitoring...
21 CFR 820.70 - Production and process controls.
Code of Federal Regulations, 2013 CFR
2013-04-01
... process control procedures that describe any process controls necessary to ensure conformance to specifications. Where process controls are needed they shall include: (1) Documented instructions, standard operating procedures (SOP's), and methods that define and control the manner of production; (2) Monitoring...
ERIC Educational Resources Information Center
Young, Richard A.
1979-01-01
Post-tests show that the value confrontation procedure resulted in significantly greater frequency of information seeking for internally controlled subjects when compared to the reinforcement counseling and control procedures. Examines two procedures designed to enhance the career planning attitudes and behavior of rural adolescent males.…
Procedures in complex systems: the airline cockpit.
Degani, A; Wiener, E L
1997-05-01
In complex human-machine systems, successful operations depend on an elaborate set of procedures which are specified by the operational management of the organization. These procedures indicate to the human operator (in this case the pilot) the manner in which operational management intends to have various tasks done. The intent is to provide guidance to the pilots and to ensure a safe, logical, efficient, and predictable (standardized) means of carrying out the objectives of the job. However, procedures can become a hodge-podge. Inconsistent or illogical procedures may lead to noncompliance by operators. Based on a field study with three major airlines, the authors propose a model for procedure development called the "Four P's": philosophy, policies, procedures, and practices. Using this model as a framework, the authors discuss the intricate issue of designing flight-deck procedures, and propose a conceptual approach for designing any set of procedures. The various factors, both external and internal to the cockpit, that must be considered for procedure design are presented. In particular, the paper addresses the development of procedures for automated cockpits--a decade-long, and highly controversial issue in commercial aviation. Although this paper is based on airline operations, we assume that the principles discussed here are also applicable to other high-risk supervisory control systems, such as space flight, manufacturing process control, nuclear power production, and military operations.
Procedural Metacognition and False Belief Understanding in 3- to 5-Year-Old Children
Bernard, Stéphane; Proust, Joëlle; Clément, Fabrice
2015-01-01
Some studies, so far limited in number, suggest the existence of procedural metacognition in young children, that is, the practical capacity to monitor and control one’s own cognitive activity in a given task. The link between procedural metacognition and false belief understanding is currently under theoretical discussion. If data with primates seem to indicate that procedural metacognition and false belief understanding are not related, no study in developmental psychology has investigated this relation in young children. The present paper aims, first, to supplement the findings concerning young children’s abilities to monitor and control their uncertainty (procedural metacognition) and, second, to explore the relation between procedural metacognition and false belief understanding. To examine this, 82 3- to 5-year-old children were presented with an opt-out task and with 3 false belief tasks. Results show that children can rely on procedural metacognition to evaluate their perceptual access to information, and that success in false belief tasks does not seem related to success in the task we used to evaluate procedural metacognition. These results are coherent with a procedural view of metacognition, and are discussed in the light of recent data from primatology and developmental psychology. PMID:26517260
Procedural Metacognition and False Belief Understanding in 3- to 5-Year-Old Children.
Bernard, Stéphane; Proust, Joëlle; Clément, Fabrice
2015-01-01
Some studies, so far limited in number, suggest the existence of procedural metacognition in young children, that is, the practical capacity to monitor and control one's own cognitive activity in a given task. The link between procedural metacognition and false belief understanding is currently under theoretical discussion. If data with primates seem to indicate that procedural metacognition and false belief understanding are not related, no study in developmental psychology has investigated this relation in young children. The present paper aims, first, to supplement the findings concerning young children's abilities to monitor and control their uncertainty (procedural metacognition) and, second, to explore the relation between procedural metacognition and false belief understanding. To examine this, 82 3- to 5-year-old children were presented with an opt-out task and with 3 false belief tasks. Results show that children can rely on procedural metacognition to evaluate their perceptual access to information, and that success in false belief tasks does not seem related to success in the task we used to evaluate procedural metacognition. These results are coherent with a procedural view of metacognition, and are discussed in the light of recent data from primatology and developmental psychology.
Hommel, Gerhard; Bretz, Frank; Maurer, Willi
2011-07-01
Global tests and multiple test procedures are often based on ordered p values. Such procedures are available for arbitrary dependence structures as well as for specific dependence assumptions of the test statistics. Most of these procedures have been considered as global tests. Multiple test procedures can be obtained by applying the closure principle in order to control the familywise error rate, or by using the false discovery rate as a criterion for type I error rate control. We provide an overview and present examples showing the importance of these procedures in medical research. Finally, we discuss modifications when different weights for the hypotheses of interest are chosen.
40 CFR 89.406 - Pre-test procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Pre-test procedures. 89.406 Section 89...) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Exhaust Emission Test Procedures § 89.406 Pre-test procedures. (a) Allow a minimum of 30 minutes warmup in the standby or operating...
40 CFR 89.406 - Pre-test procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Pre-test procedures. 89.406 Section 89...) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Exhaust Emission Test Procedures § 89.406 Pre-test procedures. (a) Allow a minimum of 30 minutes warmup in the standby or operating...
40 CFR 89.406 - Pre-test procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Pre-test procedures. 89.406 Section 89...) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Exhaust Emission Test Procedures § 89.406 Pre-test procedures. (a) Allow a minimum of 30 minutes warmup in the standby or operating...
40 CFR 89.406 - Pre-test procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Pre-test procedures. 89.406 Section 89...) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Exhaust Emission Test Procedures § 89.406 Pre-test procedures. (a) Allow a minimum of 30 minutes warmup in the standby or operating...
40 CFR 89.406 - Pre-test procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Pre-test procedures. 89.406 Section 89...) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Exhaust Emission Test Procedures § 89.406 Pre-test procedures. (a) Allow a minimum of 30 minutes warmup in the standby or operating...
40 CFR 94.109 - Test procedures for Category 3 marine engines.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Test procedures for Category 3 marine... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM MARINE COMPRESSION-IGNITION ENGINES Test Procedures § 94.109 Test procedures for Category 3 marine engines. (a) Gaseous emissions shall be measured using the test...
40 CFR 94.109 - Test procedures for Category 3 marine engines.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Test procedures for Category 3 marine... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM MARINE COMPRESSION-IGNITION ENGINES Test Procedures § 94.109 Test procedures for Category 3 marine engines. (a) Gaseous emissions shall be measured using the test...
Hypnosis for Acute Procedural Pain: A Critical Review.
Kendrick, Cassie; Sliwinski, Jim; Yu, Yimin; Johnson, Aimee; Fisher, William; Kekecs, Zoltán; Elkins, Gary
2016-01-01
Clinical evidence for the effectiveness of hypnosis in the treatment of acute procedural pain was critically evaluated based on reports from randomized controlled clinical trials (RCTs). Results from the 29 RCTs meeting inclusion criteria suggest that hypnosis decreases pain compared to standard care and attention control groups and that it is at least as effective as comparable adjunct psychological or behavioral therapies. In addition, applying hypnosis in multiple sessions prior to the day of the procedure produced the highest percentage of significant results. Hypnosis was most effective in minor surgical procedures. However, interpretations are limited by considerable risk of bias. Further studies using minimally effective control conditions and systematic control of intervention dose and timing are required to strengthen conclusions.
HYPNOSIS FOR ACUTE PROCEDURAL PAIN: A Critical Review
Kendrick, Cassie; Sliwinski, Jim; Yu, Yimin; Johnson, Aimee; Fisher, William; Kekecs, Zoltán; Elkins, Gary
2015-01-01
Clinical evidence for the effectiveness of hypnosis in the treatment of acute, procedural pain was critically evaluated based on reports from randomized controlled clinical trials (RCTs). Results from the 29 RCTs meeting inclusion criteria suggest that hypnosis decreases pain compared to standard care and attention control groups and that it is at least as effective as comparable adjunct psychological or behavioral therapies. In addition, applying hypnosis in multiple sessions prior to the day of the procedure produced the highest percentage of significant results. Hypnosis was most effective in minor surgical procedures. However, interpretations are limited by considerable risk of bias. Further studies using minimally effective control conditions and systematic control of intervention dose and timing are required to strengthen conclusions. PMID:26599994
Acceptance procedures for dense-graded mixes
DOT National Transportation Integrated Search
2001-03-01
Recent literature related to acceptance procedures for dense-graded mixtures is summarized. Current state of practice and development of acceptance procedures are reviewed. Many agencies are reducing the number of process control-related parameters i...
Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.
2006-01-01
The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance and quality-control data were stored in the laboratory's LabMaster data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality-control samples analyzed from July 1999 through June 2001. Results for the quality-control samples for 18 analytical procedures were evaluated for bias and precision. Control charts indicate that data for eight of the analytical procedures were occasionally biased for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, total monomeric aluminum, total aluminum, calcium, chloride and nitrate (ion chromatography and colormetric method) and sulfate. The total aluminum and dissolved organic carbon procedures were biased throughout the analysis period for the high-concentration sample, but were within control limits. The calcium and specific conductance procedures were biased throughout the analysis period for the low-concentration sample, but were within control limits. The magnesium procedure was biased for the high-concentration and low concentration samples, but was within control limits. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 14 of 15 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. The data-quality objective was not met for dissolved organic carbon. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 17 of the 18 analytes. At least 90 percent of the samples met data-quality objectives for all analytes except ammonium (81 percent of samples met objectives), chloride (75 percent of samples met objectives), and sodium (86 percent of samples met objectives). Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated good data quality over the time period, with most ratings for each sample in the good to excellent range. The P-sample (low-ionic-strength constituents) analysis had one satisfactory rating for the specific conductance procedure in one study. The T-sample (trace constituents) analysis had one satisfactory rating for the aluminum procedure in one study and one unsatisfactory rating for the sodium procedure in another. The remainder of the samples had good or excellent ratings for each study. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 89 percent of the samples met data-quality objectives for 10 of the 14 analytes; the exceptions were ammonium, total aluminum, dissolved organic carbon, and sodium. Results indicate a positive bias for the ammonium procedure in all studies. Data-quality objectives were not met in 50 percent of samples analyzed for total aluminum, 38 percent of samples analyzed for dissolved organic carbon, and 27 percent of samples analyzed for sodium. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 91 percent of the samples analyzed for calcium, chloride, fluoride, magnesium, pH, potassium, and sulfate. Data-quality objectives were met by 75 percent of the samples analyzed for sodium and 58 percent of the samples analyzed for specific conductance.
Field Evaluation of Fracture Control in Tunnel Blasting
DOT National Transportation Integrated Search
1979-12-01
The objective of this research was to implement fracture control procedures in a tunnel project and to assess the practicality, advantages, disadvantages, performance and cost effectiveness of fracture control methods against smooth blasting procedur...
Kulkarni, S; Johnson, P C D; Kettles, S; Kasthuri, R S
2012-01-01
Objective : To assess the effects of playing patient-selected music during interventional procedures on (1) the doses of sedation and analgesia and (2) anxiety levels. Methods : Patients undergoing interventional radiological procedures were randomised to either the intervention (music) or the control (no music) group. Patients in the intervention group had music of their choice played via headphones during the procedure. The primary outcomes were reductions in the doses of drugs for sedation (midazolam) and analgesia (fentanyl). Anxiety levels were assessed both before and after the procedure using the validated State Anxiety Inventory. Mean pulse rate and average of mean blood pressures were also recorded before and during the procedures as surrogate indicators of anxiety levels. Results : 100 patients were randomised in a 1:1 ratio. There were 58 males and 42 females, with a mean age of 58 years. Sedation was required in 21 (42%) patients in the music group compared with 30 (60%) patients in the control group (p=0.046). The mean [standard deviation (SD)] midazolam dose was 2.1 mg (2.3 mg) in the control group and 1.3 mg (2.2 mg) in the music group (p=0.027). The mean (SD) fentanyl dose was 29 mg (40 mg) in the control group and 18 mg (34 mg) in the music group (p=0.055). There was no significant effect of music on the change from baseline in anxiety levels (p=0.74), pulse rate (p=0.56) or blood pressure (p=0.34). Conclusion : Sedation requirements are significantly reduced by playing self-selected music to the patient during interventional radiology procedures. By lowering sedation during interventional radiology, music makes the procedure safer. It also contributes favourably to the overall patient experience. PMID:22422386
İşlekdemir, Burcu; Kaya, Nurten
2016-01-01
Patients generally prefer to have their family present during medical or nursing interventions. Family presence is assumed to reduce anxiety, especially during painful interventions. This study employed a randomized controlled experimental design to determine the effects of family presence on pain and anxiety during invasive nursing procedures. The study population consisted of patients hospitalized in the observation unit of the internal medicine section in the emergency department of a university hospital. The sample comprised 138 patients assigned into the experimental and control groups by drawing lots. The invasive nursing procedure was carried out in the presence of family members, for members of the experimental group, and without family members, for members of the control group. Thus, the effects of family presence on pain and anxiety during the administration of an invasive nursing procedure to patients were analyzed. The results showed that members of the experimental and control groups did not differ with respect to the pain and state anxiety scores during the intervention. Family presence does not influence the participants' pain and anxiety during an invasive nursing procedure. Thus, the decision regarding family presence during such procedures should be based on patient preference. Copyright © 2015 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Ingvarsson, Einar T.; Kramer, Rachel L.; Carp, Charlotte L.; Pétursdóttir, Anna I.; Macias, Heather
2016-01-01
We evaluated the use of a blocked-trials procedure to establish complex stimulus control over intraverbal responses. The participants were four young boys with a diagnosis of autism who had struggled to master intraverbals. The blocked-trials procedures involved presentation of stimuli in separate trial blocks. The trial blocks gradually reduced…
Schneider, Emily N; Riley, Regan; Espey, Eve; Mishra, Shiraz I; Singh, Rameet H
2017-03-01
To evaluate whether inhaled nitrous oxide with oxygen (N 2 O/O 2 ) is associated with less pain compared to oral sedation for pain management during in-office hysteroscopic sterilization. This double blinded randomized controlled trial enrolled women undergoing in-office hysteroscopic sterilization. All participants received pre-procedure intramuscular ketorolac and a standardized paracervical block. The intervention group also received N 2 O/O 2 via a nasal mask titrated to a maximum 70%:30% mixture by a nurse during the procedure and placebo pills pre-procedure and the active control group received inhaled O 2 during the procedure and 5/325 mg hydrocodone/acetaminophen and 1 mg lorazepam pre-procedure. The primary outcome was maximum procedure pain on a 100 mm Visual Analog Scale (VAS with anchors at 0=no pain and 100=worst imaginable pain) assessed 3-5 min post procedure. Thirty women per treatment arm were required to detect a clinically significant pain difference of 20 mm. Seventy-two women, 36 per study arm, were randomized. Mean age of participants was 34.1±5.7 years and mean BMI was 30.1±6.6kg/m 2 . Mean maximum procedure pain scores were 22.8±27.6 mm and 54.5±32.7 mm for intervention and control groups, respectively (p<.001). Most study participants (97%) stated N 2 O/O 2 should be offered for gynecologic office procedures and 86% would pay for it if not a covered benefit. N 2 O/O 2 decreased pain with in-office hysteroscopic sterilization compared to oral sedation and is an effective pain management option for this procedure. Given its safety and favorable side effect profile, N 2 O/O 2 can be used for pain management for in-office hysteroscopic sterilization and adds a safe, easily administered option to currently available strategies. Copyright © 2016 Elsevier Inc. All rights reserved.
Evaluation of signal timing and coordination procedures.
DOT National Transportation Integrated Search
1985-01-01
Based on a review of available literature, recommended procedures for timing the various types of signals are provided. Specifically, procedures are included for both pretimed and vehicle-actuated controllers located at isolated intersections and at ...
Acceptance procedures for dense-graded mixes : literature review.
DOT National Transportation Integrated Search
2001-03-01
Recent literature related to acceptance procedures for dense-graded mixtures is summarized. Current state of practice and development of acceptance procedures are reviewed. Many agencies are reducing the number of process control-related parameters i...
Code of Federal Regulations, 2010 CFR
2010-04-01
... CONSUMPTION INFANT FORMULA QUALITY CONTROL PROCEDURES Quality Control Procedures for Assuring Nutrient Content of Infant Formulas § 106.90 Coding. The manufacturer shall code all infant formulas in conformity...
Standard Reference Specimens in Quality Control of Engineering Surfaces
Song, J. F.; Vorburger, T. V.
1991-01-01
In the quality control of engineering surfaces, we aim to understand and maintain a good relationship between the manufacturing process and surface function. This is achieved by controlling the surface texture. The control process involves: 1) learning the functional parameters and their control values through controlled experiments or through a long history of production and use; 2) maintaining high accuracy and reproducibility with measurements not only of roughness calibration specimens but also of real engineering parts. In this paper, the characteristics, utilizations, and limitations of different classes of precision roughness calibration specimens are described. A measuring procedure of engineering surfaces, based on the calibration procedure of roughness specimens at NIST, is proposed. This procedure involves utilization of check specimens with waveform, wavelength, and other roughness parameters similar to functioning engineering surfaces. These check specimens would be certified under standardized reference measuring conditions, or by a reference instrument, and could be used for overall checking of the measuring procedure and for maintaining accuracy and agreement in engineering surface measurement. The concept of “surface texture design” is also suggested, which involves designing the engineering surface texture, the manufacturing process, and the quality control procedure to meet the optimal functional needs. PMID:28184115
Endoscopic and laparoscopic treatment of gastroesophageal reflux.
Watson, David I; Immanuel, Arul
2010-04-01
Gastroesophageal reflux is extremely common in Western countries. For selected patients, there is an established role for the surgical treatment of reflux, and possibly an emerging role for endoscopic antireflux procedures. Randomized trials have compared medical versus surgical management, laparoscopic versus open surgery and partial versus total fundoplications. However, the evidence base for endoscopic procedures is limited to some small sham-controlled studies, and cohort studies with short-term follow-up. Laparoscopic fundoplication has been shown to be an effective antireflux operation. It facilitates quicker convalescence and is associated with fewer complications, but has a similar longer term outcome compared with open antireflux surgery. In most randomized trials, antireflux surgery achieves at least as good control of reflux as medical therapy, and these studies support a wider application of surgery for the treatment of moderate-to-severe reflux. Laparoscopic partial fundoplication is an effective surgical procedure with fewer side effects, and it may achieve high rates of patient satisfaction at late follow-up. Many of the early endoscopic antireflux procedures have failed to achieve effective reflux control, and they have been withdrawn from the market. Newer procedures have the potential to fashion a surgical fundoplication. However, at present there is insufficient evidence to establish the safety and efficacy of endoscopic procedures for the treatment of gastroesophageal reflux, and no endoscopic procedure has achieved equivalent reflux control to that achieved by surgical fundoplication.
Control of Risks Through the Use of Procedures: A Method for Evaluating the Change in Risk
NASA Technical Reports Server (NTRS)
Praino, Gregory T.; Sharit, Joseph
2010-01-01
This paper considers how procedures can be used to control risks faced by an organization and proposes a means of recognizing if a particular procedure reduces risk or contributes to the organization's exposure. The proposed method was developed out of the review of work documents and the governing procedures performed in the wake of the Columbia accident by NASA and the Space Shuttle prime contractor, United Space Alliance, LLC. A technique was needed to understand the rules, or procedural controls, in place at the time in the context of how important the role of each rule was. The proposed method assesses procedural risks, the residual risk associated with a hazard after a procedure's influence is accounted for, by considering each clause of a procedure as a unique procedural control that may be beneficial or harmful. For procedural risks with consequences severe enough to threaten the survival of the organization, the method measures the characteristics of each risk on a scale that is an alternative to the traditional consequence/likelihood couple. The dual benefits of the substitute scales are that they eliminate both the need to quantify a relationship between different consequence types and the need for the extensive history a probabilistic risk assessment would require. Control Value is used as an analog for the consequence, where the value of a rule is based on how well the control reduces the severity of the consequence when operating successfully. This value is composed of two parts: the inevitability of the consequence in the absence of the control, and the opportunity to intervene before the consequence is realized. High value controls will be ones where there is minimal need for intervention but maximum opportunity to actively prevent the outcome. Failure Likelihood is used as the substitute for the conventional likelihood of the outcome. For procedural controls, a failure is considered to be any non-malicious violation of the rule, whether intended or not. The model used for describing the Failure Likelihood considers how well a task was established by evaluating that task on five components. The components selected to define a well established task are: that it be defined, assigned to someone capable, that they be trained appropriately, that the actions be organized to enable proper completion and that some form of independent monitoring be performed. Validation of the method was based on the information provided by a group of experts in Space Shuttle ground processing when they were presented with 5 scenarios that identified a clause from a procedure. For each scenario, they recorded their perception of how important the associated rule was and how likely it was to fail. They then rated the components of Control Value and Failure Likelihood for all the scenarios. The order in which each reviewer ranked the scenarios Control Value and Failure Likelihood was compared to the order in which they ranked the scenarios for each of the associated components; inevitability and opportunity for Control Value and definition, assignment, training, organization and monitoring for Failure Likelihood. This order comparison showed how the components contributed to a relative relationship to the substitute risk element. With the relationship established for Space Shuttle ground processing, this method can be used to gauge if the introduction or removal of a particular rule will increase or decrease the .risk associated with the hazard it is intended to control.
75 FR 35497 - Updated Guidance: Prevention Strategies for Seasonal Influenza in Healthcare Settings
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-22
...-generating procedure precautions, surveillance, and environmental and engineering controls. CDC will consider... procedures. Implementing environmental and engineering infection control measures. [[Page 35499
Hybrid Position/Force Control of an Active Handheld Micromanipulator for Membrane Peeling
Wells, Trent S.; Yang, Sungwook; MacLachlan, Robert A.; Lobes, Louis A.; Martel, Joseph N.; Riviere, Cameron N.
2015-01-01
Background Peeling procedures in retinal surgery require micron-scale manipulation and control of sub-tactile forces. Methods Hybrid position/force control of an actuated handheld microsurgical instrument is presented as a means for simultaneously improving positioning accuracy and reducing forces to prevent avoidable trauma to tissue. The system response was evaluated, and membrane-peeling trials were performed by four test subjects in both artificial and animal models. Results Maximum force was reduced by 56% in both models as compared to position control. No statistically significant effect on procedure duration was observed. Conclusions A hybrid position/force control system has been implemented that successfully attenuates forces and minimizes unwanted excursions during microsurgical procedures such as membrane peeling. Results also suggest that improvements in safety using this technique may be attained without increasing the duration of the procedure. PMID:25962836
Conway, Aaron; Page, Karen; Rolley, John; Fulbrook, Paul
2013-08-01
Side effects of the medications used for procedural sedation and analgesia in the cardiac catheterisation laboratory are known to cause impaired respiratory function. Impaired respiratory function poses considerable risk to patient safety as it can lead to inadequate oxygenation. Having knowledge about the conditions that predict impaired respiratory function prior to the procedure would enable nurses to identify at-risk patients and selectively implement intensive respiratory monitoring. This would reduce the possibility of inadequate oxygenation occurring. To identify pre-procedure risk factors for impaired respiratory function during nurse-administered procedural sedation and analgesia in the cardiac catheterisation laboratory. Retrospective matched case-control. 21 cases of impaired respiratory function were identified and matched to 113 controls from a consecutive cohort of patients over 18 years of age. Conditional logistic regression was used to identify risk factors for impaired respiratory function. With each additional indicator of acute illness, case patients were nearly two times more likely than their controls to experience impaired respiratory function (OR 1.78; 95% CI 1.19-2.67; p = 0.005). Indicators of acute illness included emergency admission, being transferred from a critical care unit for the procedure or requiring respiratory or haemodynamic support in the lead up to the procedure. Several factors that predict the likelihood of impaired respiratory function were identified. The results from this study could be used to inform prospective studies investigating the effectiveness of interventions for impaired respiratory function during nurse-administered procedural sedation and analgesia in the cardiac catheterisation laboratory.
Dynamics of the cognitive procedural learning in alcoholics with Korsakoff's syndrome.
Beaunieux, Hélène; Pitel, Anne L; Witkowski, Thomas; Vabret, François; Viader, Fausto; Eustache, Francis
2013-06-01
While procedures acquired before the development of amnesia are likely to be preserved in alcoholic patients with Korsakoff's syndrome, the ability of Korsakoff patients (KS) to learn new cognitive procedures is called in question. According to the Adaptive Control of Thoughts model, learning a new cognitive procedure requires highly controlled processes in the initial cognitive phase, which may be difficult for KS with episodic and working memory deficits. The goals of the present study were to examine the learning dynamics of KS compared with uncomplicated alcoholic patients (AL) and control subjects (CS) and to determine the contribution of episodic and working memory abilities in cognitive procedural learning performance. Fourteen KS, 15 AL, and 15 CS were submitted to 40 trials (4 daily learning sessions) of the Tower of Toronto task (disk-transfer task similar to the tower of Hanoi task) as well as episodic and working memory tasks. The 10 KS who were able to perform the cognitive procedural learning task obtained lower results than both CS and AL. The cognitive phase was longer in the Korsakoff's syndrome group than in the other 2 groups but did not differ between the 3 groups any more when episodic memory abilities were controlled. Our results indicate that KS have impaired cognitive procedural learning abilities compared with both AL and CS. Episodic memory deficits observed in KS result in a delayed transition from the cognitive learning phase to more advanced learning phases and, as a consequence, in an absence of automation of the procedure within 40 trials. Copyright © 2012 by the Research Society on Alcoholism.
Sequential Tests of Multiple Hypotheses Controlling Type I and II Familywise Error Rates
Bartroff, Jay; Song, Jinlin
2014-01-01
This paper addresses the following general scenario: A scientist wishes to perform a battery of experiments, each generating a sequential stream of data, to investigate some phenomenon. The scientist would like to control the overall error rate in order to draw statistically-valid conclusions from each experiment, while being as efficient as possible. The between-stream data may differ in distribution and dimension but also may be highly correlated, even duplicated exactly in some cases. Treating each experiment as a hypothesis test and adopting the familywise error rate (FWER) metric, we give a procedure that sequentially tests each hypothesis while controlling both the type I and II FWERs regardless of the between-stream correlation, and only requires arbitrary sequential test statistics that control the error rates for a given stream in isolation. The proposed procedure, which we call the sequential Holm procedure because of its inspiration from Holm’s (1979) seminal fixed-sample procedure, shows simultaneous savings in expected sample size and less conservative error control relative to fixed sample, sequential Bonferroni, and other recently proposed sequential procedures in a simulation study. PMID:25092948
42 CFR 493.1256 - Standard: Control procedures.
Code of Federal Regulations, 2010 CFR
2010-10-01
... for having control procedures that monitor the accuracy and precision of the complete analytic process..., include two control materials, including one that is capable of detecting errors in the extraction process... control materials having previously determined statistical parameters. (e) For reagent, media, and supply...
49 CFR 195.446 - Control room management.
Code of Federal Regulations, 2010 CFR
2010-10-01
... written control room management procedures that implement the requirements of this section. The procedures... define the roles and responsibilities of a controller during normal, abnormal, and emergency operating... operator must define each of the following: (1) A controller's authority and responsibility to make...
Matar, Eman M; Arabiat, Diana H; Foster, Mandie J
2016-11-01
This research was undertaken with the purpose of testing two research hypotheses regarding the efficacy of 10% oral glucose solution on procedural pain associated with venepuncture and nasopharyngeal suctioning within three neonatal intensive care units (NICU). The hypotheses were formulated from previous conclusions reached by other researchers highlighting the efficacy of sucrose solutions on neonates' pain responses during minor painful procedures. A quasi-experimental trial utilising a time series design with one group was used. Data from a total of 90 neonates included 60 neonates who underwent a venepuncture and 30 neonates who underwent a nasopharyngeal suctioning procedure for clinical purposes. The neonate's pain response for each procedure was scored using the Neonatal Pain Assessment Scale (NPAS) on two separate occasions over three time periods. The pre-procedural score (T 0 ) when the neonate received no sucrose, the inter-procedural score (T 1 ) when the neonate was given 2ml of 10% glucose solution two minutes before the procedure (intervention group) or where oral glucose was withheld (control group) and the post-procedural score (T 2 ) being at the end of the procedure. The results showed the mean NPAS scores in response to venepuncture or nasopharyngeal suctioning were significantly lower in the intervention group than the control group. This showed that oral glucose (10%) had a positive effect on the pain response during venepuncture and nasopharyngeal suctioning procedures. Copyright © 2015 Elsevier Inc. All rights reserved.
Teaching procedural skills to medical students: A pilot procedural skills lab.
Katz, Laurence M; Finch, Alexander; McKinnish, Tyler; Gilliland, Kurt; Tolleson-Rinehart, Sue; Marks, Bonita L
2017-01-01
Medical students have limited confidence in performing procedural skills. A pilot study was conducted to evaluate the effect of a multifaceted Procedural Skills Lab (PSL) on the confidence of medical students to perform procedural skills. Twelve 2nd year medical students were randomly selected to participate in a pilot PSL. The PSL students met with an instructor for 2 h once a week for 4 weeks. Students participated in a flipped classroom and spaced education program before laboratory sessions that included a cadaver laboratory. Procedural skills included a focused assessment with sonography in trauma (FAST) scan, cardiac echocardiogram, lumbar puncture, arthrocentesis, and insertion of intraosseous and intravenous catheters. Students in the PSL were asked to rank their confidence in performing procedural skills before and after completion of the laboratory sessions (Wilcoxon ranked-sum test). A web-based questionnaire was also emailed to all 2nd year medical students to establish a baseline frequency for observing, performing, and confidence performing procedural skills (Mann-Whitney U-test). Fifty-nine percent (n = 106) of 180 2nd year medical students (n = 12 PSL students [treatment group], n = 94 [control group]) completed the survey. Frequency of observation, performance, and confidence in performing procedural skills was similar between the control and treatment groups at baseline. There was an increased confidence level (p < 0.001) for performing all procedural skills for the treatment group after completion of the PSL. An innovative PSL may increase students' confidence to perform procedural skills. Future studies will examine competency after a PSL.
False Discovery Control in Large-Scale Spatial Multiple Testing
Sun, Wenguang; Reich, Brian J.; Cai, T. Tony; Guindani, Michele; Schwartzman, Armin
2014-01-01
Summary This article develops a unified theoretical and computational framework for false discovery control in multiple testing of spatial signals. We consider both point-wise and cluster-wise spatial analyses, and derive oracle procedures which optimally control the false discovery rate, false discovery exceedance and false cluster rate, respectively. A data-driven finite approximation strategy is developed to mimic the oracle procedures on a continuous spatial domain. Our multiple testing procedures are asymptotically valid and can be effectively implemented using Bayesian computational algorithms for analysis of large spatial data sets. Numerical results show that the proposed procedures lead to more accurate error control and better power performance than conventional methods. We demonstrate our methods for analyzing the time trends in tropospheric ozone in eastern US. PMID:25642138
Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.
2009-01-01
The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance and quality-control data were stored in the laboratory's Lab Master data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality control samples analyzed from July 2003 through June 2005. Results for the quality-control samples for 20 analytical procedures were evaluated for bias and precision. Control charts indicate that data for five of the analytical procedures were occasionally biased for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, total monomeric aluminum, pH, silicon, and sodium. Seven of the analytical procedures were biased throughout the analysis period for the high-concentration sample, but were within control limits; these procedures were: dissolved organic carbon, chloride, nitrate (ion chromatograph), nitrite, silicon, sodium, and sulfate. The calcium and magnesium procedures were biased throughout the analysis period for the low-concentration sample, but were within control limits. The total aluminum and specific conductance procedures were biased for the high-concentration and low-concentration samples, but were within control limits. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 17 of 18 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. The data-quality objective was not met for dissolved organic carbon. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 18 of the 22 analytes. At least 85 percent of the samples met data-quality objectives for all analytes except total monomeric aluminum (82 percent of samples met objectives), total aluminum (77 percent of samples met objectives), chloride (80 percent of samples met objectives), fluoride (76 percent of samples met objectives), and nitrate (ion chromatograph) (79 percent of samples met objectives). The ammonium and total dissolved nitrogen did not meet the data-quality objectives. Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated good data quality over the time period, with ratings for each sample in the satisfactory, good, and excellent ranges or less than 10 percent error. The P-sample (low-ionic-strength constituents) analysis had one marginal and two unsatisfactory ratings for the chloride procedure. The T-sample (trace constituents)analysis had two unsatisfactory ratings and one high range percent error for the aluminum procedure. The N-sample (nutrient constituents) analysis had one marginal rating for the nitrate procedure. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 84 percent of the samples met data-quality objectives for 11 of the 14 analytes; the exceptions were ammonium, total aluminum, and acid-neutralizing capacity. The ammonium procedure did not meet data quality objectives in all studies. Data-quality objectives were not met in 23 percent of samples analyzed for total aluminum and 45 percent of samples analyzed acid-neutralizing capacity. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 86 percent of the samples analyzed for calcium, chloride, fluoride, magnesium, pH, potassium, sodium, and sulfate. Data-quality objectives were not met by samples analyzed for fluoride.
Chen, Xiongzhi; Doerge, Rebecca W; Heyse, Joseph F
2018-05-11
We consider multiple testing with false discovery rate (FDR) control when p values have discrete and heterogeneous null distributions. We propose a new estimator of the proportion of true null hypotheses and demonstrate that it is less upwardly biased than Storey's estimator and two other estimators. The new estimator induces two adaptive procedures, that is, an adaptive Benjamini-Hochberg (BH) procedure and an adaptive Benjamini-Hochberg-Heyse (BHH) procedure. We prove that the adaptive BH (aBH) procedure is conservative nonasymptotically. Through simulation studies, we show that these procedures are usually more powerful than their nonadaptive counterparts and that the adaptive BHH procedure is usually more powerful than the aBH procedure and a procedure based on randomized p-value. The adaptive procedures are applied to a study of HIV vaccine efficacy, where they identify more differentially polymorphic positions than the BH procedure at the same FDR level. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Marschall, Jonas; Hopkins-Broyles, Diane; Jones, Marilyn; Fraser, Victoria J; Warren, David K
2007-11-01
In 2000, the rate of surgical site infections (SSIs) associated with pacemaker and implantable cardioverter-defibrillator (ICD) procedures performed in the cardiothoracic operating rooms of hospital A was 16% (19 of 116 procedures resulted in infections). This study investigates risks for SSI associated with these procedures in the cardiothoracic operating room. Unmatched 1 : 3 case-control study performed over a 12-month period among patients who had undergone implantation of a pacemaker and/or ICD. A standardized observation scrutinized infection control practices in the area where the procedures were performed. The cardiothoracic operating rooms of hospital A, which belongs to a hospital consortium in the midwestern United States. Patients with SSI were identified as case patients. Control patients were chosen from the group of uninfected patients who had procedures performed during the same period as case patients. A total of 19 SSIs associated with pacemaker and ICD procedures were retrospectively identified among the patients who underwent procedures in these cardiothoracic operating rooms. Culture samples were obtained from 7 patients; 2 yielded coagulase-negative Staphylococcus on culture, 2 yielded Staphylococcus aureus, 1 yielded Serratia marcescens, and 2 showed no growth. In the case-control study, age, race, sex, diabetes mellitus, smoking history, timing of antibiotic therapy, and hair removal did not differ significantly between case patients and control patients. Case patients were more likely to have an abdominal device in place (odds ratio [OR], 5.5 [95% confidence interval {CI}, 1.6-19.3]; P=.006) and less likely to have received a new implant (OR 0.3 [95% CI, 0.1-0.8]; P=.02) or to have had new leads placed (OR, 0.2 [95% CI, 0.1-0.6]; P=.003). Abdominal placement of implanted devices was associated with occurrence of an SSI after pacemaker and/or ICD procedures.
42 CFR 460.74 - Infection control.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 4 2010-10-01 2010-10-01 false Infection control. 460.74 Section 460.74 Public...) PACE Administrative Requirements § 460.74 Infection control. (a) Standard procedures. The PACE organization must follow accepted policies and standard procedures with respect to infection control, including...
42 CFR 460.74 - Infection control.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 4 2014-10-01 2014-10-01 false Infection control. 460.74 Section 460.74 Public...) PACE Administrative Requirements § 460.74 Infection control. (a) Standard procedures. The PACE organization must follow accepted policies and standard procedures with respect to infection control, including...
42 CFR 460.74 - Infection control.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 4 2012-10-01 2012-10-01 false Infection control. 460.74 Section 460.74 Public...) PACE Administrative Requirements § 460.74 Infection control. (a) Standard procedures. The PACE organization must follow accepted policies and standard procedures with respect to infection control, including...
40 CFR 63.749 - Compliance dates and determinations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... control system efficiency, Ek, as determined using the procedures specified in § 63.750(g) for control systems containing carbon adsorbers and in § 63.750(h) for control systems with other control devices, is... device is used, (A) The overall control system efficiency, Ek, as determined using the procedures...
40 CFR 63.749 - Compliance dates and determinations.
Code of Federal Regulations, 2013 CFR
2013-07-01
... control system efficiency, Ek, as determined using the procedures specified in § 63.750(g) for control systems containing carbon adsorbers and in § 63.750(h) for control systems with other control devices, is... device is used, (A) The overall control system efficiency, Ek, as determined using the procedures...
40 CFR 63.749 - Compliance dates and determinations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... control system efficiency, Ek, as determined using the procedures specified in § 63.750(g) for control systems containing carbon adsorbers and in § 63.750(h) for control systems with other control devices, is... device is used, (A) The overall control system efficiency, Ek, as determined using the procedures...
40 CFR 63.749 - Compliance dates and determinations.
Code of Federal Regulations, 2012 CFR
2012-07-01
... control system efficiency, Ek, as determined using the procedures specified in § 63.750(g) for control systems containing carbon adsorbers and in § 63.750(h) for control systems with other control devices, is... device is used, (A) The overall control system efficiency, Ek, as determined using the procedures...
40 CFR 63.749 - Compliance dates and determinations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... control system efficiency, Ek, as determined using the procedures specified in § 63.750(g) for control systems containing carbon adsorbers and in § 63.750(h) for control systems with other control devices, is... device is used, (A) The overall control system efficiency, Ek, as determined using the procedures...
21 CFR 820.40 - Document controls.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Document controls. 820.40 Section 820.40 Food and... QUALITY SYSTEM REGULATION Document Controls § 820.40 Document controls. Each manufacturer shall establish and maintain procedures to control all documents that are required by this part. The procedures shall...
21 CFR 106.20 - Ingredient control.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 2 2013-04-01 2013-04-01 false Ingredient control. 106.20 Section 106.20 Food and... CONSUMPTION INFANT FORMULA QUALITY CONTROL PROCEDURES Quality Control Procedures for Assuring Nutrient Content of Infant Formulas § 106.20 Ingredient control. (a) Except as provided in § 106.20(b), no analysis...
21 CFR 820.40 - Document controls.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Document controls. 820.40 Section 820.40 Food and... QUALITY SYSTEM REGULATION Document Controls § 820.40 Document controls. Each manufacturer shall establish and maintain procedures to control all documents that are required by this part. The procedures shall...
21 CFR 820.40 - Document controls.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Document controls. 820.40 Section 820.40 Food and... QUALITY SYSTEM REGULATION Document Controls § 820.40 Document controls. Each manufacturer shall establish and maintain procedures to control all documents that are required by this part. The procedures shall...
21 CFR 820.40 - Document controls.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Document controls. 820.40 Section 820.40 Food and... QUALITY SYSTEM REGULATION Document Controls § 820.40 Document controls. Each manufacturer shall establish and maintain procedures to control all documents that are required by this part. The procedures shall...
21 CFR 820.40 - Document controls.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Document controls. 820.40 Section 820.40 Food and... QUALITY SYSTEM REGULATION Document Controls § 820.40 Document controls. Each manufacturer shall establish and maintain procedures to control all documents that are required by this part. The procedures shall...
21 CFR 106.20 - Ingredient control.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 2 2012-04-01 2012-04-01 false Ingredient control. 106.20 Section 106.20 Food and... CONSUMPTION INFANT FORMULA QUALITY CONTROL PROCEDURES Quality Control Procedures for Assuring Nutrient Content of Infant Formulas § 106.20 Ingredient control. (a) Except as provided in § 106.20(b), no analysis...
21 CFR 106.20 - Ingredient control.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 2 2011-04-01 2011-04-01 false Ingredient control. 106.20 Section 106.20 Food and... CONSUMPTION INFANT FORMULA QUALITY CONTROL PROCEDURES Quality Control Procedures for Assuring Nutrient Content of Infant Formulas § 106.20 Ingredient control. (a) Except as provided in § 106.20(b), no analysis...
Controlling flows in microchannels with patterned surface charge and topography.
Stroock, Abraham D; Whitesides, George M
2003-08-01
This Account reviews two procedures for controlling the flow of fluids in microchannels. The first procedure involves patterning the density of charge on the inner surfaces of a channel. These patterns generate recirculating electroosmotic flows in the presence of a steady electric field. The second procedure involves patterning topography on an inner surface of a channel. These patterns generate recirculation in the cross-section of steady, pressure-driven flows. This Account summarizes applications of these flow to mixing and to controlling dispersion (band broadening).
NASA Astrophysics Data System (ADS)
Barlow, Steven J.
1986-09-01
The Air Force needs a better method of designing new and retrofit heating, ventilating and air conditioning (HVAC) control systems. Air Force engineers currently use manual design/predict/verify procedures taught at the Air Force Institute of Technology, School of Civil Engineering, HVAC Control Systems course. These existing manual procedures are iterative and time-consuming. The objectives of this research were to: (1) Locate and, if necessary, modify an existing computer-based method for designing and analyzing HVAC control systems that is compatible with the HVAC Control Systems manual procedures, or (2) Develop a new computer-based method of designing and analyzing HVAC control systems that is compatible with the existing manual procedures. Five existing computer packages were investigated in accordance with the first objective: MODSIM (for modular simulation), HVACSIM (for HVAC simulation), TRNSYS (for transient system simulation), BLAST (for building load and system thermodynamics) and Elite Building Energy Analysis Program. None were found to be compatible or adaptable to the existing manual procedures, and consequently, a prototype of a new computer method was developed in accordance with the second research objective.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-07
... Waterbody Construction and Mitigation Procedures and Request for Comments The staff of the Office of Energy...) and Wetland and Waterbody Construction and Mitigation Procedures (Procedures), dated January 17, 2003...
Naval Training Equipment Center Index of Technical Reports,
1982-09-01
741 RECOMMENDED PROCEDURES AND TRAINING NAVAL TRAINING AIDS. tAMPHIBIOUS OPERATIONS PROCEDURES AND RESEARCH PLANNING AD- 642 590 TRAINING DEVICES FOR...PROCEDURES AND RESEARCH PLANNING OBSERVATION AND FIRE CONTROL WITH FOR ANTI-AIR WARFARE TRAINING SPECIFIC REFERENCE TO THE TRAINING *AMPUTEES PROGRAM...619 AD- 707 757 NAVAL PERSONNEL *COMMUNICATION SATELLITES PROCEDURES AND RESEARCH PLANNING *COMBUSTION PRODUCTS Computer Managed Instruction by FOR
Medical Operations Console Procedure Evaluation: BME Response to Crew Call Down for an Emergency
NASA Technical Reports Server (NTRS)
Johnson-Troop; Pettys, Marianne; Hurst, Victor, IV; Smaka, Todd; Paul, Bonnie; Rosenquist, Kevin; Gast, Karin; Gillis, David; McCulley, Phyllis
2006-01-01
International Space Station (ISS) Mission Operations are managed by multiple flight control disciplines located at the lead Mission Control Center (MCC) at NASA-Johnson Space Center (JSC). ISS Medical Operations are supported by the complementary roles of Flight Surgeons (Surgeon) and Biomedical Engineer (BME) flight controllers. The Surgeon, a board certified physician, oversees all medical concerns of the crew and the BME provides operational and engineering support for Medical Operations Crew Health Care System. ISS Medical Operations is currently addressing the coordinated response to a crew call down for an emergent medical event, in particular when the BME is the only Medical Operations representative in MCC. In this case, the console procedure BME Response to Crew Call Down for an Emergency will be used. The procedure instructs the BME to contact a Surgeon as soon as possible, coordinate with other flight disciplines to establish a Private Medical Conference (PMC) for the crew and Surgeon, gather information from the crew if time permits, and provide Surgeon with pertinent console resources. It is paramount that this procedure is clearly written and easily navigated to assist the BME to respond consistently and efficiently. A total of five BME flight controllers participated in the study. Each BME participant sat in a simulated MCC environment at a console configured with resources specific to the BME MCC console and was presented with two scripted emergency call downs from an ISS crew member. Each participant used the procedure while interacting with analog MCC disciplines to respond to the crew call down. Audio and video recordings of the simulations were analyzed and each BME participant's actions were compared to the procedure. Structured debriefs were conducted at the conclusion of both simulations. The procedure was evaluated for its ability to elicit consistent responses from each BME participant. Trials were examined for deviations in procedure task completion and/or navigation, in particular the execution of the Surgeon call sequence. Debrief comments were used to analyze unclear procedural steps and to discern any discrepancies between the procedure and generally accepted BME actions. The sequence followed by BME participants differed considerably from the sequence intended by the procedure. Common deviations included the call sequence used to contact Surgeon, the content of BME and crew interaction and the gathering of pertinent console resources. Differing perceptions of task priority and imprecise language seem to have caused multiple deviations from the procedure s intended sequence. The study generated 40 recommendations for the procedure, of which 34 are being implemented. These recommendations address improving the clarity of the instructions, identifying training considerations, expediting Surgeon contact, improving cues for anticipated flight control team communication and identifying missing console tools.
21 CFR 226.58 - Laboratory controls.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Laboratory controls. Laboratory controls shall include the establishment of adequate specifications and test... establishment of master records containing appropriate specifications and a description of the test procedures... necessary laboratory test procedures to check such specifications. (c) Assays which shall be made of...
40 CFR 68.69 - Operating procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) CHEMICAL ACCIDENT PREVENTION PROVISIONS Program 3 Prevention Program § 68.69 Operating procedures. (a) The... presented by, the chemicals used in the process; (ii) Precautions necessary to prevent exposure, including engineering controls, administrative controls, and personal protective equipment; (iii) Control measures to be...
40 CFR 68.69 - Operating procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) CHEMICAL ACCIDENT PREVENTION PROVISIONS Program 3 Prevention Program § 68.69 Operating procedures. (a) The... presented by, the chemicals used in the process; (ii) Precautions necessary to prevent exposure, including engineering controls, administrative controls, and personal protective equipment; (iii) Control measures to be...
40 CFR 68.69 - Operating procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) CHEMICAL ACCIDENT PREVENTION PROVISIONS Program 3 Prevention Program § 68.69 Operating procedures. (a) The... presented by, the chemicals used in the process; (ii) Precautions necessary to prevent exposure, including engineering controls, administrative controls, and personal protective equipment; (iii) Control measures to be...
40 CFR 68.69 - Operating procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) CHEMICAL ACCIDENT PREVENTION PROVISIONS Program 3 Prevention Program § 68.69 Operating procedures. (a) The... presented by, the chemicals used in the process; (ii) Precautions necessary to prevent exposure, including engineering controls, administrative controls, and personal protective equipment; (iii) Control measures to be...
40 CFR 68.69 - Operating procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) CHEMICAL ACCIDENT PREVENTION PROVISIONS Program 3 Prevention Program § 68.69 Operating procedures. (a) The... presented by, the chemicals used in the process; (ii) Precautions necessary to prevent exposure, including engineering controls, administrative controls, and personal protective equipment; (iii) Control measures to be...
Villelli, Nicolas W; Das, Rohit; Yan, Hong; Huff, Wei; Zou, Jian; Barbaro, Nicholas M
2017-01-01
OBJECTIVE The Massachusetts health care insurance reform law passed in 2006 has many similarities to the federal Affordable Care Act (ACA). To address concerns that the ACA might negatively impact case volume and reimbursement for physicians, the authors analyzed trends in the number of neurosurgical procedures by type and patient insurance status in Massachusetts before and after the implementation of the state's health care insurance reform. The results can provide insight into the future of neurosurgery in the American health care system. METHODS The authors analyzed data from the Massachusetts State Inpatient Database on patients who underwent neurosurgical procedures in Massachusetts from 2001 through 2012. These data included patients' insurance status (insured or uninsured) and the numbers of procedures performed classified by neurosurgical procedural codes of the International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM). Each neurosurgical procedure was grouped into 1 of 4 categories based on ICD-9-CM codes: 1) tumor, 2) other cranial/vascular, 3) shunts, and 4) spine. Comparisons were performed of the numbers of procedures performed and uninsured patients, before and after the implementation of the reform law. Data from the state of New York were used as a control. All data were controlled for population differences. RESULTS After 2008, there were declines in the numbers of uninsured patients who underwent neurosurgical procedures in Massachusetts in all 4 categories. The number of procedures performed for tumor and spine were unchanged, whereas other cranial/vascular procedures increased. Shunt procedures decreased after implementation of the reform law but exhibited a similar trend to the control group. In New York, the number of spine surgeries increased, as did the percentage of procedures performed on uninsured patients. Other cranial/vascular procedures decreased. CONCLUSIONS After the Massachusetts health care insurance reform, the number of uninsured individuals undergoing neurosurgical procedures significantly decreased for all categories, but more importantly, the total number of surgeries performed did not change dramatically. To the extent that trends in Massachusetts can predict the overall US experience, we can expect that some aspects of reimbursement may be positively impacted by the ACA. Neurosurgeons, who often treat patients with urgent conditions, may be affected differently than other specialists.
21 CFR 106.20 - Ingredient control.
Code of Federal Regulations, 2010 CFR
2010-04-01
... CONSUMPTION INFANT FORMULA QUALITY CONTROL PROCEDURES Quality Control Procedures for Assuring Nutrient Content of Infant Formulas § 106.20 Ingredient control. (a) Except as provided in § 106.20(b), no analysis... prepared by the infant formula manufacturer shall be sampled and analyzed for each relied-upon nutrient...
Budgetary Control Procedures for Institutions.
ERIC Educational Resources Information Center
Powell, Ray M.
Budgetary control procedures for not-for-profit institutions are presented in this compilation of budgetary materials and ideas gathered at the Program for Institutional Administrators at the University of Notre Dame. Budgetary reporting and control are suggested as the most effective tools for coordinating and controlling the acquisition and use…
31 CFR 50.8 - Procedure for requesting determinations of controlling influence.
Code of Federal Regulations, 2014 CFR
2014-07-01
... the Treasury TERRORISM RISK INSURANCE PROGRAM General Provisions § 50.8 Procedure for requesting... controlling influence. Such submissions shall be made to the Terrorism Risk Insurance Program Office...
31 CFR 50.8 - Procedure for requesting determinations of controlling influence.
Code of Federal Regulations, 2011 CFR
2011-07-01
... the Treasury TERRORISM RISK INSURANCE PROGRAM General Provisions § 50.8 Procedure for requesting... controlling influence. Such submissions shall be made to the Terrorism Risk Insurance Program Office...
31 CFR 50.8 - Procedure for requesting determinations of controlling influence.
Code of Federal Regulations, 2012 CFR
2012-07-01
... the Treasury TERRORISM RISK INSURANCE PROGRAM General Provisions § 50.8 Procedure for requesting... controlling influence. Such submissions shall be made to the Terrorism Risk Insurance Program Office...
31 CFR 50.8 - Procedure for requesting determinations of controlling influence.
Code of Federal Regulations, 2013 CFR
2013-07-01
... the Treasury TERRORISM RISK INSURANCE PROGRAM General Provisions § 50.8 Procedure for requesting... controlling influence. Such submissions shall be made to the Terrorism Risk Insurance Program Office...
31 CFR 50.8 - Procedure for requesting determinations of controlling influence.
Code of Federal Regulations, 2010 CFR
2010-07-01
... the Treasury TERRORISM RISK INSURANCE PROGRAM General Provisions § 50.8 Procedure for requesting... controlling influence. Such submissions shall be made to the Terrorism Risk Insurance Program Office...
14 CFR 125.287 - Initial and recurrent pilot testing requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
... TRANSPORTATION (CONTINUED) AIR CARRIERS AND OPERATORS FOR COMPENSATION OR HIRE: CERTIFICATION AND OPERATIONS... air navigation aids appropriate to the operation of pilot authorization, including, when applicable, instrument approach facilities and procedures; (5) Air traffic control procedures, including IFR procedures...
A procedure to detect abnormal sensorimotor control in adolescents with idiopathic scoliosis.
Pialasse, Jean-Philippe; Mercier, Pierre; Descarreaux, Martin; Simoneau, Martin
2017-09-01
This work identifies, among adolescents with idiopathic scoliosis, those demonstrating impaired sensorimotor control through a classification procedure comparing the amplitude of their vestibular-evoked postural responses. The sensorimotor control of healthy adolescents (n=17) and adolescents with idiopathic scoliosis (n=52) with either mild (Cobb angle≥15° and ≤30°) or severe (Cobb angle >30°) spine deformation was assessed through galvanic vestibular stimulation. A classification procedure sorted out adolescents with idiopathic scoliosis whether the amplitude of their vestibular-evoked postural response was dissimilar or similar to controls. Compared to controls, galvanic vestibular stimulation evoked larger postural response in adolescents with idiopathic scoliosis. Nonetheless, the classification procedure revealed that only 42.5% of all patients showed impaired sensorimotor control. Consequently, identifying patients with sensorimotor control impairment would allow to apply personalized treatments, help clinicians to establish prognosis and hopefully improve the condition of patients with adolescent idiopathic scoliosis. Copyright © 2017 Elsevier B.V. All rights reserved.
An anatomically sound surgical simulation model for myringotomy and tympanostomy tube insertion.
Hong, Paul; Webb, Amanda N; Corsten, Gerard; Balderston, Janet; Haworth, Rebecca; Ritchie, Krista; Massoud, Emad
2014-03-01
Myringotomy and tympanostomy tube insertion (MT) is a common surgical procedure. Although surgical simulation has proven to be an effective training tool, an anatomically sound simulation model for MT is lacking. We developed such a model and assessed its impact on the operating room performance of senior medical students. Prospective randomized trial. A randomized single-blind controlled study of simulation training with the MT model versus no simulation training. Each participant was randomized to either the simulation model group or control group, after performing an initial MT procedure. Within two weeks of the first procedure, the students performed a second MT. All procedures were performed on real patients and rated with a Global Rating Scale by two attending otolaryngologists. Time to complete the MT was also recorded. Twenty-four senior medical students were enrolled. Control and intervention groups did not differ at baseline on their Global Rating Scale score or time to complete the MT procedure. Following simulation training, the study group received significantly higher scores (P=.005) and performed the MT procedure in significantly less time (P=.034). The control group did not improve their performance scores (P>.05) or the time to complete the procedure (P>.05). Our surgical simulation model shows promise for being a valuable teaching tool for MT for senior medical students. Such anatomically appropriate physical simulators may benefit teaching of junior trainees. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Syed, Mubin I; Karsan, Hetal; Ferral, Hector; Shaikh, Azim; Waheed, Uzma; Akhter, Talal; Gabbard, Alan; Morar, Kamal; Tyrrell, Robert
2012-02-27
To present a dedicated series of transjugular intrahepatic porto-systemic shunts (TIPS) in the elderly since data is sparse on this population group. A retrospective review was performed of patients at least 65 years of age who underwent TIPS at our institutions between 1997 and 2010. Twenty-five patients were referred for TIPS. We deemed that 2 patients were not considered appropriate candidates due to their markedly advanced liver disease. Of the 23 patients suitable for TIPS, the indications for TIPS placement was portal hypertension complicated by refractory ascites alone (n = 9), hepatic hydrothorax alone (n = 2), refractory ascites and hydrothorax (n = 1), gastrointestinal bleeding alone (n = 8), gastrointestinal bleeding and ascites (n = 3). Of these 23 attempted TIPS procedure patients, 21 patients had technically successful TIPS procedures. A total of 29 out of 32 TIPS procedures including revisions were successful in 21 patients with a mean age of 72.1 years (range 65-82 years). Three of the procedures were unsuccessful attempts at TIPS and 8 procedures were successful revisions of our existing TIPS. Sixteen of 21 patients who underwent successful TIPS (excluding 5 patients lost to follow-up) were followed for a mean of 14.7 mo. Ascites and/or hydrothorax was controlled following technically successful procedures in 12 of 13 patients. Bleeding was controlled following technically successful procedures in 10 out of 11 patients. We have demonstrated that TIPS is an effective procedure to control refractory complications of portal hypertension in elderly patients.
ERIC Educational Resources Information Center
Shih, Ching-Lin; Liu, Tien-Hsiang; Wang, Wen-Chung
2014-01-01
The simultaneous item bias test (SIBTEST) method regression procedure and the differential item functioning (DIF)-free-then-DIF strategy are applied to the logistic regression (LR) method simultaneously in this study. These procedures are used to adjust the effects of matching true score on observed score and to better control the Type I error…
Butt, Amna; Ayaz Khan, Mohammad; Khan, Ijaz; Saqib, Imad-ud-din; Hussain, Tariq; Akhter, Saeed
2017-01-01
Introduction With the increased use of extracorporeal shock wave lithotripsy (ESWL), the management of urolithiasis has become much convenient for the patients and the health care professionals alike. However, associated with the procedure is the common complaint of pain. No agreed upon pain management strategy has yet been developed for the procedure. We compared the effect of different analgesia drug regiments for pain control. Methodology A randomised controlled trial was carried out in Shifa International Hospital from between July 2015 to January 2016. A total of 135 patients were divided into three groups; group A received 30 g lidocaine 2% gel applied locally on corresponding lumber area 30 minutes before the procedure, group B received oral naproxen sodium 550 mg 45 minutes before the procedure, and group C received both oral naproxen and lidocaine gel. Patients were supplemented with intravenous nalbuphine during the procedure. The pain was assessed with 0-10 visual analogue scale. Both pre-procedure and post-procedure pain score was measured. Results Among 135 patients, 105 (77.8%) were male and 29 (21.5%) were female with mean age of 38.7 ± 1.31 years. There was no difference of mean pain score or need for supplemental intravenous nalbuphine between groups B and C but there was significantly decreased mean pain score and need for supplemental intravenous nalbuphine in groups B and C in comparison with group A. Conclusion The use of oral naproxen sodium with or without the addition of lidocaine gel during ESWL is a promising option for pain management during the procedure with significant improvement in comparison with lidocaine gel alone. PMID:28560121
Bowers, N; Eisenberg, E; Montbriand, J; Jaskolka, J; Roche-Nagle, G
2017-02-01
As vascular procedures become more complex, patient understanding of their treatment(s) can become more difficult. We wished to evaluate the utility of multimedia presentations (MPs) to improve patient understanding of their vascular interventions. Patients undergoing endovascular aneurysm repair (EVAR), peripheral angioplasty, Hickman catheter and peripherally inserted central catheter (PICC) insertion were randomized into a control group receiving traditional verbal consent, and a MP group that were shown a two minute simplified video of their procedure on an iPad™ computer in addition to the traditional verbal consent. After obtaining consent, all patients completed a questionnaire assessing their comprehension of the procedure, and satisfaction with the consent process. Satisfaction was rated on a 5 point Likert scale with 5 being 'very helpful' in understanding the procedure. Ninety-three patients were recruited for this study, 62% of which were male. The intervention significantly increased total comprehension in all procedure types controlling for procedure type (multimedia vs. control; F = 9.14, P = .003). A second ANOVA showed there was a significant main effect by intervention (F = 44.06, p < .000) with those in the intervention group showing higher overall satisfaction scores after controlling for surgery type. This study suggests that patients find the use of MP during the consent process to be helpful in patient understanding and that there is improved satisfaction. Given the rapid rate of innovation in vascular interventions, increased regular use of MPs to help patients understand their procedures would be beneficial in the care of patients undergoing vascular interventions. Copyright © 2015 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.
General considerations and updates in pediatric gastrointestinal diagnostic endoscopy
2010-01-01
Gastrointestinal and colonic endoscopic examinations have been performed in pediatric patients in Korea for 3 decades. Endoscopic procedures are complex and may be unsafe if special concerns are not considered. Many things have to be kept in mind before, during, and after the procedure. Gastrointestinal endoscopy is one of the most frequently performed procedure in children nowadays, Since the dimension size of the endoscopy was modified for pediatric patients 15 years ago, endoscopic procedures are almost performed routinely in pediatric gastrointestinal patients. The smaller size of the scope let the physicians approach the diagnostic and therapeutic endoscopic procedures. But this is an invasive procedure, so the procedure itself may provoke an emergence state. The procedure-related complications can more easily occur in pediatric patients. Sedation-related or procedure-related respiratory, cardiovascular complications are mostly important and critical in the care. The endoscopists are required to consider diverse aspects of the procedure - patient preparation, indications and contraindications, infection controls, sedation methods, sedative medicines and the side effects of each medicine, monitoring during and after the procedure, and complications related with the procedure and medicines - to perform the procedure successfully and safely. This article presents some important guidelines and recommendations for gastrointestinal endoscopy through literature review. PMID:21189965
Behavioral Treatment of Pseudobulbar Affect: A Case Report.
Perotti, Laurence P; Cummings, Latiba D; Mercado, Janyna
2016-04-01
To determine if it is possible to successfully treat pseudobulbar affect (PBA) using a behavioral approach. Two experiments were conducted, each a double reversal design with the same single subject in both. The first experiment tested the hypothesis that the rate of PBA could be controlled by manipulation of its consequences. The second experiment tested the hypothesis that use of a self-control procedure would control the rate of PBA. Rate of PBA could not be controlled by consequence manipulation, but rate of PBA could be controlled through use of a self-control procedure. Pending confirmatory research, behavioral interventions utilizing self-control procedures should be considered in patients with PBA. © 2016 Wiley Periodicals, Inc.
21 CFR 106.20 - Ingredient control.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 2 2014-04-01 2014-04-01 false Ingredient control. 106.20 Section 106.20 Food and... CONSUMPTION INFANT FORMULA QUALITY CONTROL PROCEDURES (Eff. until 7-10-14) Quality Control Procedures for Assuring Nutrient Content of Infant Formulas § 106.20 Ingredient control. (a) Except as provided in § 106...
48 CFR 1.304 - Agency control and compliance procedures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Agency control and compliance procedures. 1.304 Section 1.304 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Agency Acquisition Regulations 1.304 Agency control...
17 CFR 240.13a-15 - Controls and procedures.
Code of Federal Regulations, 2011 CFR
2011-04-01
... based must be a suitable, recognized control framework that is established by a body or group that has..., without limitation, controls and procedures designed to ensure that information required to be disclosed... disclosure. (f) The term internal control over financial reporting is defined as a process designed by, or...
17 CFR 240.13a-15 - Controls and procedures.
Code of Federal Regulations, 2010 CFR
2010-04-01
... based must be a suitable, recognized control framework that is established by a body or group that has..., without limitation, controls and procedures designed to ensure that information required to be disclosed... disclosure. (f) The term internal control over financial reporting is defined as a process designed by, or...
Risk factors for postoperative urinary tract infection following midurethral sling procedures.
Doganay, Melike; Cavkaytar, Sabri; Kokanali, Mahmut Kuntay; Ozer, Irfan; Aksakal, Orhan Seyfi; Erkaya, Salim
2017-04-01
To identify the potential risk factors for urinary tract infections following midurethral sling procedures. 556 women who underwent midurethral sling procedure due to stress urinary incontinence over a four-year period were reviewed in this retrospective study. Of the study population, 280 women underwent TVT procedures and 276 women underwent TOT procedures. Patients were evaluated at 4-8 weeks postoperatively and were investigated for the occurrence of a urinary tract infection. Patients who experienced urinary tract infection were defined as cases, and patients who didn't were defined as controls. All data were collected from medical records. Multivariate logistic regression model was used to identify the risk factors for urinary tract infection. Of 556 women, 58 (10.4%) were defined as cases while 498 (89.6%) were controls. The mean age of women in cases (57.8±12.9years) was significantly greater than in controls (51.8±11.2years) (p<0.001). The presence of menopausal status, previous abdominal surgery, preoperative antibiotic treatment due to urinary tract infection, concomitant vaginal hysterectomy and cystocele repair, TVT procedure and postoperative postvoiding residual bladder volume ≥100ml were more common in cases than in controls. However, in multivariate regression analysis model presence of preoperative urinary tract infection [OR (95% CI)=0.1 (0.1-0.7); p=0.013], TVT procedure [OR (95% CI)=8.4 (3.1-22.3); p=0.000] and postoperative postvoiding residual bladder volume ≥100ml [OR (95% CI)=4.6 (1.1-19.2); p=0.036] were significant independent risk factors for urinary tract infection following midurethral slings CONCLUSION: Urinary tract infection after midurethral sling procedures is a relatively common complication. The presence of preoperative urinary tract infection, TVT procedure and postoperative postvoiding residual bladder volume ≥100ml may increase the risk of this complication. Identification of these factors could help surgeons to minimize this complicationby developing effective strategies. Copyright © 2017. Published by Elsevier B.V.
Multiple Hollow Cathode Wear Testing for the Space Station Plasma Contactor
NASA Technical Reports Server (NTRS)
Soulas, George C.
1994-01-01
A wear test of four hollow cathodes was conducted to resolve issues associated with the Space Station plasma contactor. The objectives of this test were to evaluate unit-to-unit dispersions, verify the transportability of contamination control protocols developed by the project, and to evaluate cathode contamination control and activation procedures to enable simplification of the gas feed system and heater power processor. These objectives were achieved by wear testing four cathodes concurrently to 2000 hours. Test results showed maximum unit-to-unit deviations for discharge voltages and cathode tip temperatures to be +/-3 percent and +/-2 percent, respectively, of the nominal values. Cathodes utilizing contamination control procedures known to increase cathode lifetime showed no trends in their monitored parameters that would indicate a possible failure, demonstrating that contamination control procedures had been successfully transferred. Comparisons of cathodes utilizing and not utilizing a purifier or simplified activation procedure showed similar behavior during wear testing and pre- and post-test performance characterizations. This behavior indicates that use of simplified cathode systems and procedures is consistent with long cathode lifetimes.
48 CFR 1503.500-71 - Procedures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Business Practices 1503.500-71 Procedures. (a) A contractor's system of management controls should provide... 48 Federal Acquisition Regulations System 6 2011-10-01 2011-10-01 false Procedures. 1503.500-71 Section 1503.500-71 Federal Acquisition Regulations System ENVIRONMENTAL PROTECTION AGENCY GENERAL...
40 CFR 60.3019 - What site-specific documentation is required?
Code of Federal Regulations, 2010 CFR
2010-07-01
... required? 60.3019 Section 60.3019 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR...) Incinerator startup, shutdown, and malfunction procedures. (4) Procedures for maintaining proper combustion air supply levels. (5) Procedures for operating the incinerator and associated air pollution control...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Procedures. 545.801 Section 545.801 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY TALIBAN (AFGHANISTAN) SANCTIONS REGULATIONS Procedures § 545...
Rouchy, R C; Moreau-Gaudry, A; Chipon, E; Aubry, S; Pazart, L; Lapuyade, B; Durand, M; Hajjam, M; Pottier, S; Renard, B; Logier, R; Orry, X; Cherifi, A; Quehen, E; Kervio, G; Favelle, O; Patat, F; De Kerviler, E; Hughes, C; Medici, M; Ghelfi, J; Mounier, A; Bricault, I
2017-07-06
Interventional radiology includes a range of minimally invasive image-guided diagnostic and therapeutic procedures that have become routine clinical practice. Each procedure involves a percutaneous needle insertion, often guided using computed tomography (CT) because of its availability and usability. However, procedures remain complicated, in particular when an obstacle must be avoided, meaning that an oblique trajectory is required. Navigation systems track the operator's instruments, meaning the position and progression of the instruments are visualised in real time on the patient's images. A novel electromagnetic navigation system for CT-guided interventional procedures (IMACTIS-CT®) has been developed, and a previous clinical trial demonstrated improved needle placement accuracy in navigation-assisted procedures. In the present trial, we are evaluating the clinical benefit of the navigation system during the needle insertion step of CT-guided procedures in the thoraco-abdominal region. This study is designed as an open, multicentre, prospective, randomised, controlled interventional clinical trial and is structured as a standard two-arm, parallel-design, individually randomised trial. A maximum of 500 patients will be enrolled. In the experimental arm (navigation system), the procedures are carried out using navigation assistance, and in the active comparator arm (CT), the procedures are carried out with conventional CT guidance. The randomisation is stratified by centre and by the expected difficulty of the procedure. The primary outcome of the trial is a combined criterion to assess the safety (number of serious adverse events), efficacy (number of targets reached) and performance (number of control scans acquired) of navigation-assisted, CT-guided procedures as evaluated by a blinded radiologist and confirmed by an expert committee in case of discordance. The secondary outcomes are (1) the duration of the procedure, (2) the satisfaction of the operator and (3) the irradiation dose delivered, with (4) subgroup analysis according to the expected difficulty of the procedure, as well as an evaluation of (5) the usability of the device. This trial addresses the lack of published high-level evidence studies in which navigation-assisted CT-guided interventional procedures are evaluated. This trial is important because it addresses the problems associated with conventional CT guidance and is particularly relevant because the number of interventional radiology procedures carried out in routine clinical practice is increasing. ClinicalTrials.gov identifier: NCT01896219 . Registered on 5 July 2013.
NASA Spinoff Article: Automated Procedures To Improve Safety on Oil Rigs
NASA Technical Reports Server (NTRS)
Garud, Sumedha
2013-01-01
On May 11th, 2013, two astronauts emerged from the interior of the International Space Station (ISS) and worked their way toward the far end of spacecraft. Over the next 51/2 hours, the two replaced an ammonia pump that had developed a significant leak a few days before. On the ISS, ammonia serves the vital role of cooling components-in this case, one of the station's eight solar arrays. Throughout the extravehicular activity (EVA), the astronauts stayed in constant contact with mission control: every movement, every action strictly followed a carefully planned set of procedures to maximize crew safety and the chances of success. Though the leak had come as a surprise, NASA was prepared to handle it swiftly thanks in part to the thousands of procedures that have been written to cover every aspect of the ISS's operations. The ISS is not unique in this regard: Every NASA mission requires well-written procedures-or detailed lists of step-by-step instructions-that cover how to operate equipment in any scenario, from normal operations to the challenges created by malfunctioning hardware or software. Astronauts and mission control train and drill extensively in procedures to ensure they know what the proper procedures are and when they should be used. These procedures used to be exclusively written on paper, but over the past decade, NASA has transitioned to digital formats. Electronic-based documentation simplifies storage and use, allowing astronauts and flight controllers to find instructions more quickly and display them through a variety of media. Electronic procedures are also a crucial step toward automation: once instructions are digital, procedure display software can be designed to assist in authoring, reviewing, and even executing them.
21 CFR 111.103 - What are the requirements under this subpart F for written procedures?
Code of Federal Regulations, 2010 CFR
2010-04-01
... MANUFACTURING, PACKAGING, LABELING, OR HOLDING OPERATIONS FOR DIETARY SUPPLEMENTS Production and Process Control... quality control operations, including written procedures for conducting a material review and making a...
Analytical procedure validation and the quality by design paradigm.
Rozet, Eric; Lebrun, Pierre; Michiels, Jean-François; Sondag, Perceval; Scherder, Tara; Boulanger, Bruno
2015-01-01
Since the adoption of the ICH Q8 document concerning the development of pharmaceutical processes following a quality by design (QbD) approach, there have been many discussions on the opportunity for analytical procedure developments to follow a similar approach. While development and optimization of analytical procedure following QbD principles have been largely discussed and described, the place of analytical procedure validation in this framework has not been clarified. This article aims at showing that analytical procedure validation is fully integrated into the QbD paradigm and is an essential step in developing analytical procedures that are effectively fit for purpose. Adequate statistical methodologies have also their role to play: such as design of experiments, statistical modeling, and probabilistic statements. The outcome of analytical procedure validation is also an analytical procedure design space, and from it, control strategy can be set.
Guidelines for procedural pain in the newborn
Lago, Paola; Garetti, Elisabetta; Merazzi, Daniele; Pieragostini, Luisa; Ancora, Gina; Pirelli, Anna; Bellieni, Carlo Valerio
2009-01-01
Despite accumulating evidence that procedural pain experienced by newborn infants may have acute and even long-term detrimental effects on their subsequent behaviour and neurological outcome, pain control and prevention remain controversial issues. Our aim was to develop guidelines based on evidence and clinical practice for preventing and controlling neonatal procedural pain in the light of the evidence-based recommendations contained in the SIGN classification. A panel of expert neonatologists used systematic review, data synthesis and open discussion to reach a consensus on the level of evidence supported by the literature or customs in clinical practice and to describe a global analgesic management, considering pharmacological, non-pharmacological, behavioural and environmental measures for each invasive procedure. There is strong evidence to support some analgesic measures, e.g. sucrose or breast milk for minor invasive procedures, and combinations of drugs for tracheal intubation. Many other pain control measures used during chest tube placement and removal, screening and treatment for ROP, or for postoperative pain, are still based not on evidence, but on good practice or expert opinions. Conclusion: These guidelines should help improving the health care professional's awareness of the need to adequately manage procedural pain in neonates, based on the strongest evidence currently available. PMID:19484828
Serials Control System Procedures and Policies.
ERIC Educational Resources Information Center
Schlembach, Mary C.
This document includes procedures and policies for a networked serials control system originally developed at the Grainger Engineering Library Information Center at the University of Illinois at Urbana-Champaign (UIUC). The serials control systems encompass serials processing, public service, and end-user functions. The system employs a…
21 CFR 225.65 - Equipment cleanout procedures.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR MEDICATED FEEDS Product Quality Control § 225.65 Equipment cleanout procedures. (a) Adequate cleanout procedures for all equipment used in the manufacture... sequential production of feeds. (2) If flushing is utilized, the flush material shall be properly identified...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 31 Money and Finance:Treasury 3 2011-07-01 2011-07-01 false Procedures. 594.801 Section 594.801 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY GLOBAL TERRORISM SANCTIONS REGULATIONS Procedures § 594.801...
78 FR 32085 - Amendment of Class E Airspace; Eureka, NV
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-29
... instrument approach procedures at the airport. This improves the safety and management of Instrument Flight... aircraft using the RNAV (GPS) standard instrument approach procedures at Eureka Airport. Class E airspace...) standard instrument approach procedures at the airport. Additional controlled airspace extending upward...
40 CFR 1074.101 - Procedures for California nonroad authorization requests.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Procedures for California nonroad... (CONTINUED) AIR POLLUTION CONTROLS PREEMPTION OF STATE STANDARDS AND PROCEDURES FOR WAIVER OF FEDERAL... California nonroad authorization requests. (a) California must request authorization from the Administrator...
40 CFR 1074.101 - Procedures for California nonroad authorization requests.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 33 2011-07-01 2011-07-01 false Procedures for California nonroad... (CONTINUED) AIR POLLUTION CONTROLS PREEMPTION OF STATE STANDARDS AND PROCEDURES FOR WAIVER OF FEDERAL... California nonroad authorization requests. (a) California must request authorization from the Administrator...
40 CFR 1074.101 - Procedures for California nonroad authorization requests.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Procedures for California nonroad... (CONTINUED) AIR POLLUTION CONTROLS PREEMPTION OF STATE STANDARDS AND PROCEDURES FOR WAIVER OF FEDERAL... California nonroad authorization requests. (a) California must request authorization from the Administrator...
40 CFR 1074.101 - Procedures for California nonroad authorization requests.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Procedures for California nonroad... (CONTINUED) AIR POLLUTION CONTROLS PREEMPTION OF STATE STANDARDS AND PROCEDURES FOR WAIVER OF FEDERAL... California nonroad authorization requests. (a) California must request authorization from the Administrator...
40 CFR 1074.101 - Procedures for California nonroad authorization requests.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Procedures for California nonroad... (CONTINUED) AIR POLLUTION CONTROLS PREEMPTION OF STATE STANDARDS AND PROCEDURES FOR WAIVER OF FEDERAL... California nonroad authorization requests. (a) California must request authorization from the Administrator...
30 CFR 57.4330 - Surface firefighting, evacuation, and rescue procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4330 Surface... coordinated in advance with available firefighting organizations. (b) Fire alarm procedures or systems shall...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 31 Money and Finance:Treasury 3 2014-07-01 2014-07-01 false Procedures. 510.801 Section 510.801 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY NORTH KOREA SANCTIONS REGULATIONS Procedures § 510.801...
49 CFR 193.2713 - Training: operations and maintenance.
Code of Federal Regulations, 2014 CFR
2014-10-01
... maintenance activities; and (iii) To carry out aspects of the operating and maintenance procedures under... instructions on the facility operations, including controls, functions, and operating procedures; and (ii) To understand the LNG transfer procedures provided under § 193.2513. (b) A written plan of continuing...
49 CFR 193.2713 - Training: operations and maintenance.
Code of Federal Regulations, 2010 CFR
2010-10-01
... maintenance activities; and (iii) To carry out aspects of the operating and maintenance procedures under... instructions on the facility operations, including controls, functions, and operating procedures; and (ii) To understand the LNG transfer procedures provided under § 193.2513. (b) A written plan of continuing...
49 CFR 193.2713 - Training: operations and maintenance.
Code of Federal Regulations, 2011 CFR
2011-10-01
... maintenance activities; and (iii) To carry out aspects of the operating and maintenance procedures under... instructions on the facility operations, including controls, functions, and operating procedures; and (ii) To understand the LNG transfer procedures provided under § 193.2513. (b) A written plan of continuing...
49 CFR 193.2713 - Training: operations and maintenance.
Code of Federal Regulations, 2012 CFR
2012-10-01
... maintenance activities; and (iii) To carry out aspects of the operating and maintenance procedures under... instructions on the facility operations, including controls, functions, and operating procedures; and (ii) To understand the LNG transfer procedures provided under § 193.2513. (b) A written plan of continuing...
49 CFR 193.2713 - Training: operations and maintenance.
Code of Federal Regulations, 2013 CFR
2013-10-01
... maintenance activities; and (iii) To carry out aspects of the operating and maintenance procedures under... instructions on the facility operations, including controls, functions, and operating procedures; and (ii) To understand the LNG transfer procedures provided under § 193.2513. (b) A written plan of continuing...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 31 Money and Finance:Treasury 3 2013-07-01 2013-07-01 false Procedures. 510.801 Section 510.801 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY NORTH KOREA SANCTIONS REGULATIONS Procedures § 510.801...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 31 Money and Finance:Treasury 3 2011-07-01 2011-07-01 false Procedures 510.801 Section 510.801 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY NORTH KOREA SANCTIONS REGULATIONS Procedures § 510.801...
40 CFR 1065.12 - Approval of alternate procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Applicability and General Provisions § 1065.12 Approval of... individual engine manufacturer may request to use an alternate procedure. This also means that an instrument... show that your engines comply with all applicable emission standards. (3) Any relevant factors...
40 CFR 1065.12 - Approval of alternate procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Applicability and General Provisions § 1065.12 Approval of... individual engine manufacturer may request to use an alternate procedure. This also means that an instrument... show that your engines comply with all applicable emission standards. (3) Any relevant factors...
40 CFR 1065.12 - Approval of alternate procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Applicability and General Provisions § 1065.12 Approval of... individual engine manufacturer may request to use an alternate procedure. This also means that an instrument... show that your engines comply with all applicable emission standards. (3) Any relevant factors...
14 CFR 125.287 - Initial and recurrent pilot testing requirements.
Code of Federal Regulations, 2011 CFR
2011-01-01
..., instrument approach facilities and procedures; (5) Air traffic control procedures, including IFR procedures... certificate holder; (2) For each type of airplane to be flown by the pilot, the airplane powerplant, major components and systems, major appliances, performance and operating limitations, standard and emergency...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 31 Money and Finance:Treasury 3 2012-07-01 2012-07-01 false Procedures 510.801 Section 510.801 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY NORTH KOREA SANCTIONS REGULATIONS Procedures § 510.801...
40 CFR 1066.215 - Summary of verification procedures for chassis dynamometers.
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CONTINUED) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer Specifications § 1066.215 Summary... judgment. (c) Automated dynamometer verifications and calibrations. In some cases, dynamometers are... specified in this subpart. You may use these automated functions instead of following the procedures we...
Dudoit, Sandrine; Gilbert, Houston N.; van der Laan, Mark J.
2014-01-01
Summary This article proposes resampling-based empirical Bayes multiple testing procedures for controlling a broad class of Type I error rates, defined as generalized tail probability (gTP) error rates, gTP(q, g) = Pr(g(Vn, Sn) > q), and generalized expected value (gEV) error rates, gEV(g) = E[g(Vn, Sn)], for arbitrary functions g(Vn, Sn) of the numbers of false positives Vn and true positives Sn. Of particular interest are error rates based on the proportion g(Vn, Sn) = Vn/(Vn + Sn) of Type I errors among the rejected hypotheses, such as the false discovery rate (FDR), FDR = E[Vn/(Vn + Sn)]. The proposed procedures offer several advantages over existing methods. They provide Type I error control for general data generating distributions, with arbitrary dependence structures among variables. Gains in power are achieved by deriving rejection regions based on guessed sets of true null hypotheses and null test statistics randomly sampled from joint distributions that account for the dependence structure of the data. The Type I error and power properties of an FDR-controlling version of the resampling-based empirical Bayes approach are investigated and compared to those of widely-used FDR-controlling linear step-up procedures in a simulation study. The Type I error and power trade-off achieved by the empirical Bayes procedures under a variety of testing scenarios allows this approach to be competitive with or outperform the Storey and Tibshirani (2003) linear step-up procedure, as an alternative to the classical Benjamini and Hochberg (1995) procedure. PMID:18932138
Pitel, Anne Lise; Witkowski, Thomas; Vabret, François; Guillery-Girard, Bérengère; Desgranges, Béatrice; Eustache, Francis; Beaunieux, Hélène
2007-02-01
Chronic alcoholism is known to impair the functioning of episodic and working memory, which may consequently reduce the ability to learn complex novel information. Nevertheless, semantic and cognitive procedural learning have not been properly explored at alcohol treatment entry, despite its potential clinical relevance. The goal of the present study was therefore to determine whether alcoholic patients, immediately after the weaning phase, are cognitively able to acquire complex new knowledge, given their episodic and working memory deficits. Twenty alcoholic inpatients with episodic memory and working memory deficits at alcohol treatment entry and a control group of 20 healthy subjects underwent a protocol of semantic acquisition and cognitive procedural learning. The semantic learning task consisted of the acquisition of 10 novel concepts, while subjects were administered the Tower of Toronto task to measure cognitive procedural learning. Analyses showed that although alcoholic subjects were able to acquire the category and features of the semantic concepts, albeit slowly, they presented impaired label learning. In the control group, executive functions and episodic memory predicted semantic learning in the first and second halves of the protocol, respectively. In addition to the cognitive processes involved in the learning strategies invoked by controls, alcoholic subjects seem to attempt to compensate for their impaired cognitive functions, invoking capacities of short-term passive storage. Regarding cognitive procedural learning, although the patients eventually achieved the same results as the controls, they failed to automate the procedure. Contrary to the control group, the alcoholic groups' learning performance was predicted by controlled cognitive functions throughout the protocol. At alcohol treatment entry, alcoholic patients with neuropsychological deficits have difficulty acquiring novel semantic and cognitive procedural knowledge. Compared with controls, they seem to use more costly learning strategies, which are nonetheless less efficient. These learning disabilities need to be considered when treatment requiring the acquisition of complex novel information is envisaged.
Compliance with infection control practices in an university hospital dental clinic
Mutters, Nico T.; Hägele, Ulrike; Hagenfeld, Daniel; Hellwig, Elmar; Frank, Uwe
2014-01-01
Aim: Compliance with infection control practices is the key to quality care and excellence in dentistry. Infection control remains one of the most cost-beneficial interventions available. However, implementing control procedures requires full compliance of the whole dental team. The aim of our study was to measure the compliance in daily clinical practice. Methods: The compliance with infection control practices in dentistry by dental health care personnel (DHCP) in a German university dental clinic was observed during clinical work. In addition, a survey was conducted to assess the individual knowledge about infection control procedures. Contamination of the workplace during invasive dental procedures was tested, as well. Results: A total of 58 invasive dental treatments implying close contacts between HCWs and patients were scrutinized. All HCWs (100%) wore gloves during dental work, but in some cases (female dentists: 14.3%; dental assistants: 28.6%) gloves were neither changed nor hands were disinfected between different activities or patient contacts (female dentists: 68.6%; male dentists: 60.9%; dental assistants: 93%). Only 31.4% of female and 39.1% of male dentists carried out adequate hygienic hand disinfection after removing gloves. Male dentists wore significantly more often (100%) protective eyewear compared to 77.1% of female dentists (p<0.05). In addition, most of female dentists (62.9%) and dental assistants (80.7%) wore jewelry during dental procedures. Conclusion: Despite the knowledge of distinct hygiene procedures only a small percentage of dental staff performs hygiene practices according to recommended guidelines. Strict audit is clearly needed in the dental setting to ensure compliance with infection control guidelines to prevent transmission of pathogens. Our results provide insights for the development of a targeted education and training strategy to enhance compliance of dental staff especially of dental assistants with infection control procedures. PMID:25285262
Compliance with infection control practices in an university hospital dental clinic.
Mutters, Nico T; Hägele, Ulrike; Hagenfeld, Daniel; Hellwig, Elmar; Frank, Uwe
2014-01-01
Compliance with infection control practices is the key to quality care and excellence in dentistry. Infection control remains one of the most cost-beneficial interventions available. However, implementing control procedures requires full compliance of the whole dental team. The aim of our study was to measure the compliance in daily clinical practice. The compliance with infection control practices in dentistry by dental health care personnel (DHCP) in a German university dental clinic was observed during clinical work. In addition, a survey was conducted to assess the individual knowledge about infection control procedures. Contamination of the workplace during invasive dental procedures was tested, as well. A total of 58 invasive dental treatments implying close contacts between HCWs and patients were scrutinized. All HCWs (100%) wore gloves during dental work, but in some cases (female dentists: 14.3%; dental assistants: 28.6%) gloves were neither changed nor hands were disinfected between different activities or patient contacts (female dentists: 68.6%; male dentists: 60.9%; dental assistants: 93%). Only 31.4% of female and 39.1% of male dentists carried out adequate hygienic hand disinfection after removing gloves. Male dentists wore significantly more often (100%) protective eyewear compared to 77.1% of female dentists (p<0.05). In addition, most of female dentists (62.9%) and dental assistants (80.7%) wore jewelry during dental procedures. Despite the knowledge of distinct hygiene procedures only a small percentage of dental staff performs hygiene practices according to recommended guidelines. Strict audit is clearly needed in the dental setting to ensure compliance with infection control guidelines to prevent transmission of pathogens. Our results provide insights for the development of a targeted education and training strategy to enhance compliance of dental staff especially of dental assistants with infection control procedures.
Crew Procedures for Continuous Descent Arrivals Using Conventional Guidance
NASA Technical Reports Server (NTRS)
Oseguera-Lohr, Rosa M.; Williams, David H.; Lewis, Elliot T,
2007-01-01
This paper presents results from a simulation study which investigated the use of Continuous Descent Arrival (CDA) procedures for conducting a descent through a busy terminal area, using conventional transport-category automation. This research was part of the Low Noise Flight Procedures (LNFP) element within the Quiet Aircraft Technology (QAT) Project, that addressed development of flight guidance, and supporting pilot and Air Traffic Control (ATC) procedures for low noise operations. The procedures and chart were designed to be easy to understand, and to make it easy for the crew to make changes via the Flight Management Computer Control-Display Unit (FMC-CDU) to accommodate changes from ATC. The test runs were intended to represent situations typical of what exists in many of today's terminal areas, including interruptions to the descent in the form of clearances issued by ATC.
Training a Network of Electronic Neurons for Control of a Mobile Robot
NASA Astrophysics Data System (ADS)
Vromen, T. G. M.; Steur, E.; Nijmeijer, H.
An adaptive training procedure is developed for a network of electronic neurons, which controls a mobile robot driving around in an unknown environment while avoiding obstacles. The neuronal network controls the angular velocity of the wheels of the robot based on the sensor readings. The nodes in the neuronal network controller are clusters of neurons rather than single neurons. The adaptive training procedure ensures that the input-output behavior of the clusters is identical, even though the constituting neurons are nonidentical and have, in isolation, nonidentical responses to the same input. In particular, we let the neurons interact via a diffusive coupling, and the proposed training procedure modifies the diffusion interaction weights such that the neurons behave synchronously with a predefined response. The working principle of the training procedure is experimentally validated and results of an experiment with a mobile robot that is completely autonomously driving in an unknown environment with obstacles are presented.
Operational Control Procedures for the Activated Sludge Process: Appendix.
ERIC Educational Resources Information Center
West, Alfred W.
This document is the appendix for a series of documents developed by the National Training and Operational Technology Center describing operational control procedures for the activated sludge process used in wastewater treatment. Categories discussed include: control test data, trend charts, moving averages, semi-logarithmic plots, probability…
29 CFR 1910.7 - Definition and requirements for a nationally recognized testing laboratory.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., written testing procedures, and calibration and quality control programs) to perform: (i) Testing and... test standards; or (ii) Experimental testing and examining of equipment and materials for workplace..., labeled, or accepted, the following controls or services: (i) Implements control procedures for...
30 CFR 57.4330 - Surface firefighting, evacuation, and rescue procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4330 Surface... coordinated in advance with available firefighting organizations. (b) Fire alarm procedures or systems shall be established to promptly warn every person who could be endangered by a fire. (c) Fire alarm...
30 CFR 56.4330 - Firefighting, evacuation, and rescue procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Fire Prevention and Control Firefighting Procedures/alarms/drills § 56.4330 Firefighting, evacuation... organizations. (b) Fire alarm procedures or systems shall be established to pomptly warn every person who could be endangered by a fire. (c) Fire alarm systems shall be maintained in operable condition. ...
30 CFR 56.4330 - Firefighting, evacuation, and rescue procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Fire Prevention and Control Firefighting Procedures/alarms/drills § 56.4330 Firefighting, evacuation... organizations. (b) Fire alarm procedures or systems shall be established to pomptly warn every person who could be endangered by a fire. (c) Fire alarm systems shall be maintained in operable condition. ...
30 CFR 57.4330 - Surface firefighting, evacuation, and rescue procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4330 Surface... coordinated in advance with available firefighting organizations. (b) Fire alarm procedures or systems shall be established to promptly warn every person who could be endangered by a fire. (c) Fire alarm...
30 CFR 56.4330 - Firefighting, evacuation, and rescue procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Fire Prevention and Control Firefighting Procedures/alarms/drills § 56.4330 Firefighting, evacuation... organizations. (b) Fire alarm procedures or systems shall be established to pomptly warn every person who could be endangered by a fire. (c) Fire alarm systems shall be maintained in operable condition. ...
30 CFR 56.4330 - Firefighting, evacuation, and rescue procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Fire Prevention and Control Firefighting Procedures/alarms/drills § 56.4330 Firefighting, evacuation... organizations. (b) Fire alarm procedures or systems shall be established to pomptly warn every person who could be endangered by a fire. (c) Fire alarm systems shall be maintained in operable condition. ...
30 CFR 57.4330 - Surface firefighting, evacuation, and rescue procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4330 Surface... coordinated in advance with available firefighting organizations. (b) Fire alarm procedures or systems shall be established to promptly warn every person who could be endangered by a fire. (c) Fire alarm...
30 CFR 57.4330 - Surface firefighting, evacuation, and rescue procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4330 Surface... coordinated in advance with available firefighting organizations. (b) Fire alarm procedures or systems shall be established to promptly warn every person who could be endangered by a fire. (c) Fire alarm...
30 CFR 56.4330 - Firefighting, evacuation, and rescue procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 56.4330 Firefighting, evacuation... organizations. (b) Fire alarm procedures or systems shall be established to pomptly warn every person who could...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-16
....300) require the following standard operating procedures to assure appropriate use of, and precautions for, systems using electronic records and signatures: (1) Sec. 11.10 specifies procedures and controls... burden associated with the creation of standard operating procedures, validation, and certification. The...
10 CFR 32.110 - Acceptance sampling procedures under certain specific licenses.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Acceptance sampling procedures under certain specific licenses. 32.110 Section 32.110 Energy NUCLEAR REGULATORY COMMISSION SPECIFIC DOMESTIC LICENSES TO MANUFACTURE OR TRANSFER CERTAIN ITEMS CONTAINING BYPRODUCT MATERIAL Quality Control Sampling Procedures § 32...
10 CFR 32.110 - Acceptance sampling procedures under certain specific licenses.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Acceptance sampling procedures under certain specific licenses. 32.110 Section 32.110 Energy NUCLEAR REGULATORY COMMISSION SPECIFIC DOMESTIC LICENSES TO MANUFACTURE OR TRANSFER CERTAIN ITEMS CONTAINING BYPRODUCT MATERIAL Quality Control Sampling Procedures § 32...
Parikh, Rishi; Pollock, Daniel; Sharma, Jyotirmay; Edwards, Jonathan
2016-10-01
OBJECTIVE We compared risk for surgical site infection (SSI) following surgical breast procedures among 2 patient groups: those whose procedures were performed in ambulatory surgery centers (ASCs) and those whose procedures were performed in hospital-based outpatient facilities. DESIGN Cohort study using National Healthcare Safety Network (NHSN) SSI data for breast procedures performed from 2010 to 2014. METHODS Unconditional multivariate logistic regression was used to examine the association between facility type and breast SSI, adjusting for American Society of Anesthesiologists (ASA) Physical Status Classification, patient age, and duration of procedure. Other potential adjustment factors examined were wound classification, anesthesia use, and gender. RESULTS Among 124,021 total outpatient breast procedures performed between 2010 and 2014, 110,987 procedure reports submitted to the NHSN provided complete covariate data and were included in the analysis. Breast procedures performed in ASCs carried a lower risk of SSI compared with those performed in hospital-based outpatient settings. For patients aged ≤51 years, the adjusted risk ratio was 0.36 (95% CI, 0.25-0.50) and for patients >51 years old, the adjusted risk ratio was 0.32 (95% CI, 0.21-0.49). CONCLUSIONS SSI risk following breast procedures was significantly lower among ASC patients than among hospital-based outpatients. These findings should be placed in the context of study limitations, including the possibility of incomplete ascertainment of SSIs and shortcomings in the data available to control for differences in patient case mix. Additional studies are needed to better understand the role of procedural settings in SSI risk following breast procedures and to identify prevention opportunities. Infect Control Hosp Epidemiol 2016;1-7.
Syed, Mubin I; Karsan, Hetal; Ferral, Hector; Shaikh, Azim; Waheed, Uzma; Akhter, Talal; Gabbard, Alan; Morar, Kamal; Tyrrell, Robert
2012-01-01
AIM: To present a dedicated series of transjugular intrahepatic porto-systemic shunts (TIPS) in the elderly since data is sparse on this population group. METHODS: A retrospective review was performed of patients at least 65 years of age who underwent TIPS at our institutions between 1997 and 2010. Twenty-five patients were referred for TIPS. We deemed that 2 patients were not considered appropriate candidates due to their markedly advanced liver disease. Of the 23 patients suitable for TIPS, the indications for TIPS placement was portal hypertension complicated by refractory ascites alone (n = 9), hepatic hydrothorax alone (n = 2), refractory ascites and hydrothorax (n = 1), gastrointestinal bleeding alone (n = 8), gastrointestinal bleeding and ascites (n = 3). RESULTS: Of these 23 attempted TIPS procedure patients, 21 patients had technically successful TIPS procedures. A total of 29 out of 32 TIPS procedures including revisions were successful in 21 patients with a mean age of 72.1 years (range 65-82 years). Three of the procedures were unsuccessful attempts at TIPS and 8 procedures were successful revisions of our existing TIPS. Sixteen of 21 patients who underwent successful TIPS (excluding 5 patients lost to follow-up) were followed for a mean of 14.7 mo. Ascites and/or hydrothorax was controlled following technically successful procedures in 12 of 13 patients. Bleeding was controlled following technically successful procedures in 10 out of 11 patients. CONCLUSION: We have demonstrated that TIPS is an effective procedure to control refractory complications of portal hypertension in elderly patients. PMID:22400084
Burns-Nader, Sherwood; Joe, Lindsay; Pinion, Kelly
2017-09-01
Distraction is often used in conjunction with analgesics to minimize pain in pediatric burn patients during treatment procedures. Computer tablets provide many options for distraction items in one tool and are often used during medical procedures. Few studies have examined the effectiveness of tablet distraction in improving the care of pediatric burn patients. This study examines the effectiveness of tablet distraction provided by a child life specialist to minimize pain and anxiety in pediatric burn patients undergoing hydrotherapy. Thirty pediatric patients (4-12) undergoing hydrotherapy for the treatment of burns participated in this randomized clinical trial. The tablet distraction group received tablet distraction provided by a child life specialist while those in the control group received standard care. Pain was assessed through self-reports and observation reports. Anxiety was assessed through behavioral observations. Length of procedure was also recorded. Nurses reported significantly less pain for the tablet distraction group compared to the control group. There was no significant difference between groups on self-reported pain. The tablet distraction group displayed significantly less anxiety during the procedure compared to the control group. Also, the tablet distraction group returned to baseline after the procedure while those in the control group displayed higher anxiety post-procedure. There was no difference in the length of the procedure between groups. These findings suggest tablet distraction provided by a child life specialist may be an effective method for improving pain and anxiety in children undergoing hydrotherapy treatment for burns. Copyright © 2017 Elsevier Ltd and ISBI. All rights reserved.
Specific arithmetic calculation deficits in children with Turner syndrome.
Rovet, J; Szekely, C; Hockenberry, M N
1994-12-01
Study 1 compared arithmetic processing skills on the WRAT-R in 45 girls with Turner syndrome (TS) and 92 age-matched female controls. Results revealed significant underachievement by subjects with TS, which reflected their poorer performance on problems requiring the retrieval of addition and multiplication facts and procedural knowledge for addition and division operations. TS subjects did not differ qualitatively from controls in type of procedural error committed. Study 2, which compared the performance of 10 subjects with TS and 31 controls on the Keymath Diagnostic Arithmetic Test, showed that the TS group had less adequate knowledge of arithmetic, subtraction, and multiplication procedures but did not differ from controls on Fact items. Error analyses revealed that TS subjects were more likely to confuse component steps or fail to separate intermediate steps or to complete problems. TS subjects relied to a greater degree on verbal than visual-spatial abilities in arithmetic processing while their visual-spatial abilities were associated with retrieval of simple multidigit addition facts and knowledge of subtraction, multiplication, and division procedures. Differences between the TS and control groups increased with age for Keymath, but not WRAT-R, procedures. Discrepant findings are related to the different task constraints (timed vs. untimed, single vs. alternate versions, size of item pool) and the use of different strategies (counting vs. fact retrieval). It is concluded that arithmetic difficulties in females with TS are due to less adequate procedural skills, combined with poorer fact retrieval in timed testing situations, rather than to inadequate visual-spatial abilities.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haseler, Luke J., E-mail: l.haseler@griffith.edu.au; Sibbitt, Randy R., E-mail: THESIBB2@aol.com; Sibbitt, Wilmer L., E-mail: wsibbitt@salud.unm.edu
Purpose: Syringes are used for diagnostic fluid aspiration and fine-needle aspiration biopsy in interventional procedures. We determined the benefits, disadvantages, and patient safety implications of syringe and needle size on vacuum generation, hand force requirements, biopsy/fluid yield, and needle control during aspiration procedures. Materials and Methods: Different sizes (1, 3, 5, 10, and 20 ml) of the conventional syringe and aspirating mechanical safety syringe, the reciprocating procedure device, were studied. Twenty operators performed aspiration procedures with the following outcomes measured: (1) vacuum (torr), (2) time to vacuum (s), (3) hand force to generate vacuum (torr-cm{sup 2}), (4) operator difficulty duringmore » aspiration, (5) biopsy yield (mg), and (6) operator control of the needle tip position (mm). Results: Vacuum increased tissue biopsy yield at all needle diameters (P < 0.002). Twenty-milliliter syringes achieved a vacuum of -517 torr but required far more strength to aspirate, and resulted in significant loss of needle control (P < 0.002). The 10-ml syringe generated only 15% less vacuum (-435 torr) than the 20-ml device and required much less hand strength. The mechanical syringe generated identical vacuum at all syringe sizes with less hand force (P < 0.002) and provided significantly enhanced needle control (P < 0.002). Conclusions: To optimize patient safety and control of the needle, and to maximize fluid and tissue yield during aspiration procedures, a two-handed technique and the smallest syringe size adequate for the procedure should be used. If precise needle control or one-handed operation is required, a mechanical safety syringe should be considered.« less
Effects of non-pharmacological pain treatments on brain states
Jensen, Mark P.; Sherlin, Leslie H.; Askew, Robert L.; Fregni, Felipe; Witkop, Gregory; Gianas, Ann; Howe, Jon D.; Hakimian, Shahin
2013-01-01
Objective To (1) evaluate the effects of a single session of four non-pharmacological pain interventions, relative to a sham tDCS procedure, on pain and electroencephalogram- (EEG-) assessed brain oscillations, and (2) determine the extent to which procedure-related changes in pain intensity are associated with changes in brain oscillations. Methods 30 individuals with spinal cord injury and chronic pain were given an EEG and administered measures of pain before and after five procedures (hypnosis, meditation, transcranial direct current stimulation [tDCS], and neurofeedback) and a control sham tDCS procedure. Results Each procedure was associated with a different pattern of changes in brain activity, and all active procedures were significantly different from the control procedure in at least three bandwidths. Very weak and mostly non-significant associations were found between changes in EEG-assessed brain activity and pain. Conclusions Different non-pharmacological pain treatments have distinctive effects on brain oscillation patterns. However, changes in EEG-assessed brain oscillations are not significantly associated with changes in pain, and therefore such changes do not appear useful for explaining the benefits of these treatments. Significance The results provide new findings regarding the unique effects of four non-pharmacological treatments on pain and brain activity. PMID:23706958
Flightcrew Procedures for Controller Pilot Data Link Communications (CPDLC).
DOT National Transportation Integrated Search
2015-09-10
It is imperative that flightcrew procedures be developed and implemented to capitalize on the strengths of Controller Pilot Data Link Communications (CPDLC) while minimizing the possibility of error. This paper presents a sample of air carrier Standa...
49 CFR 1180.0 - Scope and purpose.
Code of Federal Regulations, 2010 CFR
2010-10-01
... OF TRANSPORTATION RULES OF PRACTICE RAILROAD ACQUISITION, CONTROL, MERGER, CONSOLIDATION PROJECT, TRACKAGE RIGHTS, AND LEASE PROCEDURES General Acquisition Procedures § 1180.0 Scope and purpose. (a... followed in control, merger, acquisition, lease, trackage rights, and any other consolidation transaction...
41 CFR 109-27.5009 - Control of hypodermic needles and syringes.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Control of hypodermic... SUPPLY AND PROCUREMENT 27-INVENTORY MANAGEMENT 27.50-Inventory Management Policies, Procedures, and Guidelines § 109-27.5009 Control of hypodermic needles and syringes. Effective procedures and practices shall...
41 CFR 109-27.5008 - Control of drug substances and potable alcohol.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Control of drug... REGULATIONS SUPPLY AND PROCUREMENT 27-INVENTORY MANAGEMENT 27.50-Inventory Management Policies, Procedures, and Guidelines § 109-27.5008 Control of drug substances and potable alcohol. Effective procedures and...
21 CFR 123.11 - Sanitation control procedures.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Sanitation control procedures. 123.11 Section 123.11 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION FISH AND FISHERY PRODUCTS General Provisions § 123.11 Sanitation control...
Details on the verification test design, measurement test procedures, and Quality assurance/Quality Control (QA/QC) procedures can be found in the test plan titled Testing and Quality Assurance Plan, MIRATECH Corporation GECO 3100 Air/Fuel Ratio Controller (SRI 2001). It can be d...
Code of Federal Regulations, 2012 CFR
2012-01-01
... rodent population and other pests under control; (6) Tailor vaccination programs to needs of farm and... and maintaining sanitation and good management practices for the control of Salmonella and Mycoplasma... management practices for the control of Salmonella and Mycoplasma infections. (a) The following procedures...
Code of Federal Regulations, 2014 CFR
2014-01-01
... rodent population and other pests under control; (6) Tailor vaccination programs to needs of farm and... and maintaining sanitation and good management practices for the control of Salmonella and Mycoplasma... management practices for the control of Salmonella and Mycoplasma infections. (a) The following procedures...
Code of Federal Regulations, 2013 CFR
2013-01-01
... rodent population and other pests under control; (6) Tailor vaccination programs to needs of farm and... and maintaining sanitation and good management practices for the control of Salmonella and Mycoplasma... management practices for the control of Salmonella and Mycoplasma infections. (a) The following procedures...
47 CFR 1.9010 - De facto control standard for spectrum leasing arrangements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 1 2012-10-01 2012-10-01 false De facto control standard for spectrum leasing... PROCEDURE Grants by Random Selection Spectrum Leasing General Policies and Procedures § 1.9010 De facto control standard for spectrum leasing arrangements. (a) Under the rules established for spectrum leasing...
47 CFR 1.9010 - De facto control standard for spectrum leasing arrangements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 1 2014-10-01 2014-10-01 false De facto control standard for spectrum leasing... PROCEDURE Grants by Random Selection Spectrum Leasing General Policies and Procedures § 1.9010 De facto control standard for spectrum leasing arrangements. (a) Under the rules established for spectrum leasing...
47 CFR 1.9010 - De facto control standard for spectrum leasing arrangements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 1 2013-10-01 2013-10-01 false De facto control standard for spectrum leasing... PROCEDURE Grants by Random Selection Spectrum Leasing General Policies and Procedures § 1.9010 De facto control standard for spectrum leasing arrangements. (a) Under the rules established for spectrum leasing...
Using Statistical Process Control to Make Data-Based Clinical Decisions.
ERIC Educational Resources Information Center
Pfadt, Al; Wheeler, Donald J.
1995-01-01
Statistical process control (SPC), which employs simple statistical tools and problem-solving techniques such as histograms, control charts, flow charts, and Pareto charts to implement continual product improvement procedures, can be incorporated into human service organizations. Examples illustrate use of SPC procedures to analyze behavioral data…
Code of Federal Regulations, 2011 CFR
2011-01-01
... and maintaining sanitation and good management practices for the control of Salmonella and Mycoplasma... management practices for the control of Salmonella and Mycoplasma infections. (a) The following procedures...) Allow no visitors except under controlled conditions to minimize the introduction of Salmonella and...
21 CFR 226.40 - Production and control procedures.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Production and control procedures. 226.40 Section 226.40 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR TYPE A MEDICATED ARTICLES Product Quality Control...
Robust decentralized power system controller design: Integrated approach
NASA Astrophysics Data System (ADS)
Veselý, Vojtech
2017-09-01
A unique approach to the design of gain scheduled controller (GSC) is presented. The proposed design procedure is based on the Bellman-Lyapunov equation, guaranteed cost and robust stability conditions using the parameter dependent quadratic stability approach. The obtained feasible design procedures for robust GSC design are in the form of BMI with guaranteed convex stability conditions. The obtained design results and their properties are illustrated in the simultaneously design of controllers for simple model (6-order) turbogenerator. The results of the obtained design procedure are a PI automatic voltage regulator (AVR) for synchronous generator, a PI governor controller and a power system stabilizer for excitation system.
NASA Technical Reports Server (NTRS)
Helly, J. J., Jr.; Bates, W. V.; Cutler, M.; Kelem, S.
1984-01-01
A new representation of malfunction procedure logic which permits the automation of these procedures using Boolean normal forms is presented. This representation is discussed in the context of the development of an expert system for space shuttle flight control including software and hardware implementation modes, and a distributed architecture. The roles and responsibility of the flight control team as well as previous work toward the development of expert systems for flight control support at Johnson Space Center are discussed. The notion of malfunction procedures as graphs is introduced as well as the concept of hardware-equivalence.
46 CFR 565.10 - Suspension procedures, period of suspension, and replacement rates.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 9 2010-10-01 2010-10-01 false Suspension procedures, period of suspension, and replacement rates. 565.10 Section 565.10 Shipping FEDERAL MARITIME COMMISSION REGULATIONS AND ACTIONS TO ADDRESS RESTRICTIVE FOREIGN MARITIME PRACTICES CONTROLLED CARRIERS § 565.10 Suspension procedures, period...
40 CFR 1066.830 - Supplemental Federal Test Procedures; overview.
Code of Federal Regulations, 2014 CFR
2014-07-01
... driving and a sequence of vehicle operation that accounts for the impact of the vehicle's air conditioner...) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Exhaust Emission Test Procedures for Motor Vehicles... results from the aggressive driving test element (§ 1066.831), the air conditioning test element (§ 1066...
40 CFR 86.1332-90 - Engine mapping procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... § 86.1332-90 Engine mapping procedures. (a) Mount test engine on the engine dynamometer. (b) Determine... 40 Protection of Environment 19 2011-07-01 2011-07-01 false Engine mapping procedures. 86.1332-90... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission...
40 CFR 86.1332-90 - Engine mapping procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... § 86.1332-90 Engine mapping procedures. (a) Mount test engine on the engine dynamometer. (b) Determine... 40 Protection of Environment 20 2012-07-01 2012-07-01 false Engine mapping procedures. 86.1332-90... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission...
40 CFR 86.1332-90 - Engine mapping procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... § 86.1332-90 Engine mapping procedures. (a) Mount test engine on the engine dynamometer. (b) Determine... 40 Protection of Environment 20 2013-07-01 2013-07-01 false Engine mapping procedures. 86.1332-90... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission...
40 CFR 1060.505 - Other procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... equipment will use another volatile liquid fuel instead of gasoline, use a test fuel that is representative... the test procedures to reflect the effects of using a fuel other than gasoline. (d) Approval. If we... CONTROL OF EVAPORATIVE EMISSIONS FROM NEW AND IN-USE NONROAD AND STATIONARY EQUIPMENT Test Procedures...
40 CFR 1066.970 - Refueling test for liquid fuels.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Refueling test for liquid fuels. 1066... POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Evaporative Emission Test Procedures Evaporative and Refueling Emission Test Procedures for Motor Vehicles § 1066.970 Refueling test for liquid fuels. Except as described...
40 CFR 1060.505 - Other procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... equipment will use another volatile liquid fuel instead of gasoline, use a test fuel that is representative... the test procedures to reflect the effects of using a fuel other than gasoline. (d) Approval. If we... CONTROL OF EVAPORATIVE EMISSIONS FROM NEW AND IN-USE NONROAD AND STATIONARY EQUIPMENT Test Procedures...
40 CFR 1060.505 - Other procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... equipment will use another volatile liquid fuel instead of gasoline, use a test fuel that is representative... the test procedures to reflect the effects of using a fuel other than gasoline. (d) Approval. If we... CONTROL OF EVAPORATIVE EMISSIONS FROM NEW AND IN-USE NONROAD AND STATIONARY EQUIPMENT Test Procedures...
40 CFR 1060.505 - Other procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... equipment will use another volatile liquid fuel instead of gasoline, use a test fuel that is representative... the test procedures to reflect the effects of using a fuel other than gasoline. (d) Approval. If we... CONTROL OF EVAPORATIVE EMISSIONS FROM NEW AND IN-USE NONROAD AND STATIONARY EQUIPMENT Test Procedures...
40 CFR 1060.505 - Other procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... equipment will use another volatile liquid fuel instead of gasoline, use a test fuel that is representative... the test procedures to reflect the effects of using a fuel other than gasoline. (d) Approval. If we... CONTROL OF EVAPORATIVE EMISSIONS FROM NEW AND IN-USE NONROAD AND STATIONARY EQUIPMENT Test Procedures...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Procedures. 367.12 Section 367.12 Banks and... EXCLUSION OF CONTRACTOR AND TERMINATION OF CONTRACTS § 367.12 Procedures. (a) FDIC shall process suspension... reconsideration, the provisions relating to the construction of time limits in 12 CFR 308.12 will control. ...
Evaluation of the CATSIB DIF Procedure in a Pretest Setting
ERIC Educational Resources Information Center
Nandakumar, Ratna; Roussos, Louis
2004-01-01
A new procedure, CATSIB, for assessing differential item functioning (DIF) on computerized adaptive tests (CATs) is proposed. CATSIB, a modified SIBTEST procedure, matches test takers on estimated ability and controls for impact-induced Type 1 error inflation by employing a CAT version of the IBTEST "regression correction." The…
40 CFR 86.227-94 - Test procedures; overview.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for 1994 and Later Model Year Gasoline-Fueled New Light-Duty Vehicles, New Light-Duty Trucks and New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.227-94 Test procedures; overview. The...
40 CFR 63.545 - Standards for fugitive dust sources.
Code of Federal Regulations, 2011 CFR
2011-07-01
... according to a standard operating procedures manual that describes in detail the measures that will be put... standard operating procedures manual shall be submitted to the Administrator or delegated authority for review and approval. (c) The controls specified in the standard operating procedures manual shall at a...
40 CFR 63.545 - Standards for fugitive dust sources.
Code of Federal Regulations, 2010 CFR
2010-07-01
... according to a standard operating procedures manual that describes in detail the measures that will be put... standard operating procedures manual shall be submitted to the Administrator or delegated authority for review and approval. (c) The controls specified in the standard operating procedures manual shall at a...
76 FR 62074 - Proposed Revision of Performance Standards for State Medicaid Fraud Control Units
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-06
... volume of case referrals and workload for each location. Performance Standard 3--Policies and Procedures A Unit establishes written policies and procedures for its operations and ensures that staff are familiar with, and adhere to, policies and procedures. In meeting this standard, the following performance...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-23
... Proposed Information Collection to OMB; Emergency Comment Request; Real Estate Settlement Procedures Act... Proposal: Real Estate Settlement Procedures Act (RESPA) Disclosures. OMB Control Number, if applicable... reinstatement of a discontinued information collection. The Real Estate Settlement Procedures Act of 1974...
40 CFR 63.1113 - Procedures for approval of alternative means of emission limitation.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Procedures for approval of alternative means of emission limitation. 63.1113 Section 63.1113 Protection of Environment ENVIRONMENTAL PROTECTION... Categories: Generic Maximum Achievable Control Technology Standards § 63.1113 Procedures for approval of...
40 CFR 86.329-79 - System response time; check procedure.
Code of Federal Regulations, 2010 CFR
2010-07-01
... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for New Gasoline-Fueled and Diesel-Fueled Heavy-Duty Engines; Gaseous Exhaust Test Procedures § 86... in step (i). (2) Capillary flow analyzers. This procedure is applicable only to analyzers that have...
40 CFR 1065.5 - Overview of this part 1065 and its relationship to the standard-setting part.
Code of Federal Regulations, 2010 CFR
2010-07-01
... PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Applicability and General... part specifies procedures that apply generally to testing various categories of engines. See the... engine. Before using this part's procedures, read the standard-setting part to answer at least the...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-30
... amendments to its evaporative emission test procedures, four-wheel drive dynamometer provisions, and vehicle... manufacturer has certified vehicles using an alternative running loss test procedure, CARB may conduct... manufacturer's approved alternative running loss test procedure; (3) provide manufacturers an option to use an...
Michel Foehn, Esther R
2015-08-01
This review presents current trends of safe and efficient anesthesia and sedation for adults and children for gastrointestinal procedures outside of the operating room with a special focus on total intravenous anesthesia (TIVA), target-controlled infusion (TCI), intravenous or topical lidocaine, and the use of the video laryngoscope. The concepts of a well tolerated and adequate anesthesia or sedation for gastrointestinal procedures outside of the operating room have to meet the needs of the adult and pediatric patients and the special requests of the gastroenterologists. Anesthesia and sedation of adults for gastrointestinal procedures with TIVA or TCI and spontaneous breathing is well established. Many institutions perform anesthesia for pediatric patients undergoing gastrointestinal procedures with an inhalational agent, especially in young children and for short procedures. Unlike adults, in young children the airways frequently must be secured with a tracheal tube or laryngeal mask. Respiration may be spontaneous, assisted, or controlled. TIVA and TCI are increasingly chosen for older children and longer procedures. A local anesthetic administered intravenously or topically to the upper airways and the use of the video laryngoscope can facilitate the insertion of the endoscope. Both anesthesiologists and nonanesthesiologists have to achieve a consensus and develop quality-improvement strategies to provide safe and efficient anesthesia and sedation for gastrointestinal procedures outside of the operating room for pediatric and adult patients. Techniques using TIVA, TCI, intravenous or topical application of lidocaine, and the video laryngoscope may improve and facilitate gastrointestinal procedures for the patients, the anesthesiologists, and the gastroenterologists.
ERIC Educational Resources Information Center
West, Alfred W.
This is the first in a series of documents developed by the National Training and Operational Technology Center describing operational control procedures for the activated sludge process used in wastewater treatment. Part I of this document deals with physical observations which should be performed during each routine control test. Part II…
Code of Federal Regulations, 2014 CFR
2014-10-01
... vapor control system designs-TB/ALL. 39.1013 Section 39.1013 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS VAPOR CONTROL SYSTEMS General § 39.1013 U.S.-flagged tank vessel certification procedures for vapor control system designs—TB/ALL. (a) For an existing Coast Guard-approved vapor...
Code of Federal Regulations, 2014 CFR
2014-10-01
... vapor control system designs-TB/ALL. 39.1015 Section 39.1015 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS VAPOR CONTROL SYSTEMS General § 39.1015 Foreign-flagged tank vessel certification procedures for vapor control system designs—TB/ALL. As an alternative to meeting the requirements...
Code of Federal Regulations, 2013 CFR
2013-10-01
... vapor control system designs-TB/ALL. 39.1015 Section 39.1015 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS VAPOR CONTROL SYSTEMS General § 39.1015 Foreign-flagged tank vessel certification procedures for vapor control system designs—TB/ALL. As an alternative to meeting the requirements...
Code of Federal Regulations, 2013 CFR
2013-10-01
... vapor control system designs-TB/ALL. 39.1013 Section 39.1013 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS VAPOR CONTROL SYSTEMS General § 39.1013 U.S.-flagged tank vessel certification procedures for vapor control system designs—TB/ALL. (a) For an existing Coast Guard-approved vapor...
Formalizing procedures for operations automation, operator training and spacecraft autonomy
NASA Technical Reports Server (NTRS)
Lecouat, Francois; Desaintvincent, Arnaud
1994-01-01
The generation and validation of operations procedures is a key task of mission preparation that is quite complex and costly. This has motivated the development of software applications providing support for procedures preparation. Several applications have been developed at MATRA MARCONI SPACE (MMS) over the last five years. They are presented in the first section of this paper. The main idea is that if procedures are represented in a formal language, they can be managed more easily with a computer tool and some automatic verifications can be performed. One difficulty is to define a formal language that is easy to use for operators and operations engineers. From the experience of the various procedures management tools developed in the last five years (including the POM, EOA, and CSS projects), MMS has derived OPSMAKER, a generic tool for procedure elaboration and validation. It has been applied to quite different types of missions, ranging from crew procedures (PREVISE system), ground control centers management procedures (PROCSU system), and - most relevant to the present paper - satellite operation procedures (PROCSAT developed for CNES, to support the preparation and verification of SPOT 4 operation procedures, and OPSAT for MMS telecom satellites operation procedures).
Cognitive Fatigue Facilitates Procedural Sequence Learning.
Borragán, Guillermo; Slama, Hichem; Destrebecqz, Arnaud; Peigneux, Philippe
2016-01-01
Enhanced procedural learning has been evidenced in conditions where cognitive control is diminished, including hypnosis, disruption of prefrontal activity and non-optimal time of the day. Another condition depleting the availability of controlled resources is cognitive fatigue (CF). We tested the hypothesis that CF, eventually leading to diminished cognitive control, facilitates procedural sequence learning. In a two-day experiment, 23 young healthy adults were administered a serial reaction time task (SRTT) following the induction of high or low levels of CF, in a counterbalanced order. CF was induced using the Time load Dual-back (TloadDback) paradigm, a dual working memory task that allows tailoring cognitive load levels to the individual's optimal performance capacity. In line with our hypothesis, reaction times (RT) in the SRTT were faster in the high- than in the low-level fatigue condition, and performance improvement was higher for the sequential than the motor components. Altogether, our results suggest a paradoxical, facilitating impact of CF on procedural motor sequence learning. We propose that facilitated learning in the high-level fatigue condition stems from a reduction in the cognitive resources devoted to cognitive control processes that normally oppose automatic procedural acquisition mechanisms.
NASA Technical Reports Server (NTRS)
Fehlberg, E.
1973-01-01
New Runge-Kutta-Nystrom formulas of the eighth, seventh, sixth, and fifth order are derived for the special second-order (vector) differential equation x = f (t,x). In contrast to Runge-Kutta-Nystrom formulas of an earlier NASA report, these formulas provide a stepsize control procedure based on the leading term of the local truncation error in x. This new procedure is more accurate than the earlier Runge-Kutta-Nystrom procedure (with stepsize control based on the leading term of the local truncation error in x) when integrating close to singularities. Two central orbits are presented as examples. For these orbits, the accuracy and speed of the formulas of this report are compared with those of Runge-Kutta-Nystrom and Runge-Kutta formulas of earlier NASA reports.
Minimizing damage to a propped fracture by controlled flowback procedures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robinson, B.M.; Holditch, S.A.; Whitehead, W.S.
1988-06-01
Severe fracture-conductivity damage can result from proppant crushing and/or proppant flowback into the wellbore. Such damage is often concentrated near the wellbore and can directly affect postfracture performance. Most of the time severe fracture-conductivity damage can be minimized by choosing the correct type of proppant for a particular well. In many cases, however, this is not enough. To minimize excessive crushing or to prevent proppant flowback, it is also necessary to control carefully the flowback of the well after the treatment. Specific procedures can be followed to minimize severe fracture-conductivity damage. These procedures involve controlling the rates at which loadmore » fluids are recovered and maximizing backpressure against the formation. These procedures require much more time and effort than is normally spent on postfracture cleanup; however, the efforts could result in better performance.« less
Memory for syntax despite amnesia.
Ferreira, Victor S; Bock, Kathryn; Wilson, Michael P; Cohen, Neal J
2008-09-01
Syntactic persistence is a tendency for speakers to reproduce sentence structures independently of accompanying meanings, words, or sounds. The memory mechanisms behind syntactic persistence are not fully understood. Although some properties of syntactic persistence suggest a role for procedural memory, current evidence suggests that procedural memory (unlike declarative memory) does not maintain the abstract, relational features that are inherent to syntactic structures. In a study evaluating the contribution of procedural memory to syntactic persistence, patients with anterograde amnesia and matched control speakers reproduced prime sentences with different syntactic structures; reproduced 0, 1, 6, or 10 neutral sentences; then spontaneously described pictures that elicited the primed structures; and finally made recognition judgments for the prime sentences. Amnesic and control speakers showed significant and equivalent syntactic persistence, despite the amnesic speakers' profoundly impaired recognition memory for the primes. Thus, syntax is maintained by procedural-memory mechanisms. This result reveals that procedural memory is capable of supporting abstract, relational knowledge.
Diagnostic equipment outside the laboratory.
Burrin, J M; Fyffe, J A
1988-01-01
A questionnaire was circulated to clinical biochemistry laboratories in the North West Thames region of the United Kingdom requesting information on extralaboratory equipment. Data on the types and numbers of instruments in use, their relationship with the laboratory, and quality assurance procedures were obtained. Laboratories were prepared to maintain equipment over which they had no responsibility for purchase, training of users, or use. The quality assurance of these instruments gave even greater cause for concern. Although internal quality control procedures were performed on many of the instruments, laboratories were involved in only a minority of these procedures. Quality control procedures and training of users were undertaken on site in less than 50% of blood gas analysers and bilirubin meters and in less than 25% of glucose meters. External quality assessment procedures were non-existent for all of the instruments in use with the exception of glucose stick meters in two laboratories. PMID:3192750
Applicability of NASA (ARC) two-segment approach procedures to Boeing Aircraft
NASA Technical Reports Server (NTRS)
Allison, R. L.
1974-01-01
An engineering study to determine the feasibility of applying the NASA (ARC) two-segment approach procedures and avionics to the Boeing fleet of commercial jet transports is presented. This feasibility study is concerned with the speed/path control and systems compability aspects of the procedures. Path performance data are provided for representative Boeing 707/727/737/747 passenger models. Thrust margin requirements for speed/path control are analyzed for still air and shearing tailwind conditions. Certification of the two-segment equipment and possible effects on existing airplane certification are discussed. Operational restrictions on use of the procedures with current autothrottles and in icing or reported tailwind conditions are recommended. Using the NASA/UAL 727 procedures as a baseline, maximum upper glide slopes for representative 707/727/737/747 models are defined as a starting point for further study and/or flight evaluation programs.
Reporting the accuracy of biochemical measurements for epidemiologic and nutrition studies.
McShane, L M; Clark, L C; Combs, G F; Turnbull, B W
1991-06-01
Procedures for reporting and monitoring the accuracy of biochemical measurements are presented. They are proposed as standard reporting procedures for laboratory assays for epidemiologic and clinical-nutrition studies. The recommended procedures require identification and estimation of all major sources of variability and explanations of laboratory quality control procedures employed. Variance-components techniques are used to model the total variability and calculate a maximum percent error that provides an easily understandable measure of laboratory precision accounting for all sources of variability. This avoids ambiguities encountered when reporting an SD that may taken into account only a few of the potential sources of variability. Other proposed uses of the total-variability model include estimating precision of laboratory methods for various replication schemes and developing effective quality control-checking schemes. These procedures are demonstrated with an example of the analysis of alpha-tocopherol in human plasma by using high-performance liquid chromatography.
40 CFR 80.141 - Interim detergent gasoline program.
Code of Federal Regulations, 2010 CFR
2010-07-01
... considered acceptable for demonstration of IVD control performance. Examples of acceptable test procedures... carburetor deposits. Examples of acceptable test procedures for demonstration of carburetor deposit control... ultimate consumer; (ii) All additized post-refinery component (PRC); and (iii) All detergent additives sold...
40 CFR 80.141 - Interim detergent gasoline program.
Code of Federal Regulations, 2011 CFR
2011-07-01
... considered acceptable for demonstration of IVD control performance. Examples of acceptable test procedures... carburetor deposits. Examples of acceptable test procedures for demonstration of carburetor deposit control... ultimate consumer; (ii) All additized post-refinery component (PRC); and (iii) All detergent additives sold...
40 CFR 80.141 - Interim detergent gasoline program.
Code of Federal Regulations, 2012 CFR
2012-07-01
... considered acceptable for demonstration of IVD control performance. Examples of acceptable test procedures... carburetor deposits. Examples of acceptable test procedures for demonstration of carburetor deposit control... ultimate consumer; (ii) All additized post-refinery component (PRC); and (iii) All detergent additives sold...
40 CFR 80.141 - Interim detergent gasoline program.
Code of Federal Regulations, 2013 CFR
2013-07-01
... considered acceptable for demonstration of IVD control performance. Examples of acceptable test procedures... carburetor deposits. Examples of acceptable test procedures for demonstration of carburetor deposit control... ultimate consumer; (ii) All additized post-refinery component (PRC); and (iii) All detergent additives sold...
40 CFR 240.205-2 - Recommended procedures: Design.
Code of Federal Regulations, 2010 CFR
2010-07-01
....205-2 Section 240.205-2 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES GUIDELINES FOR THE THERMAL PROCESSING OF SOLID WASTES Requirements and Recommended Procedures... air pollution control technology. (b) All emissions, including dust from vents, should be controlled. ...
40 CFR 240.205-2 - Recommended procedures: Design.
Code of Federal Regulations, 2011 CFR
2011-07-01
....205-2 Section 240.205-2 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES GUIDELINES FOR THE THERMAL PROCESSING OF SOLID WASTES Requirements and Recommended Procedures... air pollution control technology. (b) All emissions, including dust from vents, should be controlled. ...
48 CFR 3401.304 - Agency control and compliance procedures.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Agency control and compliance procedures. 3401.304 Section 3401.304 Federal Acquisition Regulations System DEPARTMENT OF EDUCATION ACQUISITION REGULATION GENERAL ED ACQUISITION REGULATION SYSTEM Agency Acquisition Regulations...
40 CFR 85.2208 - Alternative standards and procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... 85.2208 Section 85.2208 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF AIR POLLUTION FROM MOBILE SOURCES Emission Control System Performance... Administrator determines that the alternative standards or procedures satisfy the provisions of the Clean Air...
21 CFR 820.70 - Production and process controls.
Code of Federal Regulations, 2014 CFR
2014-04-01
... to ensure that a device conforms to its specifications. Where deviations from device specifications... specifications. Where process controls are needed they shall include: (1) Documented instructions, standard... establish and maintain procedures for changes to a specification, method, process, or procedure. Such...
21 CFR 820.70 - Production and process controls.
Code of Federal Regulations, 2012 CFR
2012-04-01
... to ensure that a device conforms to its specifications. Where deviations from device specifications... specifications. Where process controls are needed they shall include: (1) Documented instructions, standard... establish and maintain procedures for changes to a specification, method, process, or procedure. Such...
Balint, Bela; Vucetić, Dusan; Trajković-Lakić, Zlatija; Petakov, Marijana; Bugarski, Diana; Brajusković, Goran; Taseski, Jovan
2002-01-01
Cryopreservation of platelets is of great interest, since it could extend the shelf life of therapeutic platelet concentrates and facilitate stockpiling and inventory control in blood banking. Despite the use of many cryopreservation procedures the optimal cryopreservation procedure is not defined yet. We have compared the cryopreservation of human platelets by various protocols employing controlled-rate and non-controlled-rate freezing procedures in combination with different concentrations of DMSO (6% and 10%) or 5% DMSO + 6% HES combination. After storage for 1 to 3 months, samples were thawed and analyzed. Measurements included cell recovery, platelet viability according to hypotonic shock response (HSR), platelet aggregation with ADP, morphological and ultrastructural properties of defrozen platelets. Our findings show that the application of our original procedure for controlled-rate freezing consisting of six cooling steps (cooling rate 1 degree C/min) with compensation of released heat of fusion (cooling rate 2 degrees C/min) has significantly influenced the quality of thawed platelets. At the same time, a concentration of 6% DMSO proved to be the most effective. In summary, cryopreservation of human platelets using controlled-rate freezing procedure in combination with lower (6%) DMSO concentration resulted in less damage from freezing and higher recovered function of platelets.
Rubino, C; Marongiu, F; Manzo, M J; Tedde, G; Madonia, M; Campus, G V; Farace, F
2014-06-01
We have devised a low cost system to quickly infiltrate tumescent solution: we call it the "Tedde's system". This low-cost system offers an improvement in quality and quantity of the infiltration because all the procedure depends on the operators, reducing also the time of the infiltration and consequently of the whole surgical procedure. Moreover, this system can be applied to other surgical procedure that requires large infiltration volumes.
Liu, Zhiyi; Zhang, Luyao; Liu, Yanling; Gu, Yang; Sun, Tieliang
2017-11-01
We aimed to evaluate the efficiency and safety of one-step procedure combined endoscopic retrograde cholangiopancreatography (ERCP) and laparoscopic cholecystectomy (LC) for treatment of patients with cholecysto-choledocholithiasis. A prospective randomized study was performed on 63 consecutive cholecysto-choledocholithiasis patients during 2008 and 2011. The efficiency and safety of one-step procedure was assessed by comparing the two-step LC with ERCP + endoscopic sphincterotomy (EST). Outcomes including intraoperative features, postoperative features (length of stay and postoperative complications) were evaluated. One- or two-step procedure of LC with ERCP + EST was successfully performed in all patients, and common bile duct stones were completely removed. Statistical analyses showed that length of stay and pulmonary infection rate were significantly lower in the test group compared with that in the control group (P < 0.05), whereas no statistical difference in other outcomes was found between the two groups (all P > 0.05). The one-step procedure of LC with ERCP + EST is superior to the two-step procedure for treatment of patients with cholecysto-choledocholithiasis regarding to the reduced hospital stay and inhibited occurrence of pulmonary infections. Compared with two-step procedure, one-step procedure of LC with ERCP + EST may be a superior option for cholecysto-choledocholithiasis patients treatment regarding to hospital stay and pulmonary infections.
Kaneko, Hidekazu; Tamura, Hiroshi; Tate, Shunta; Kawashima, Takahiro; Suzuki, Shinya S; Fujita, Ichiro
2010-08-01
In order for patients with disabilities to control assistive devices with their own neural activity, multineuronal spike trains must be efficiently decoded because only limited computational resources can be used to generate prosthetic control signals in portable real-time applications. In this study, we compare the abilities of two vectorizing procedures (multineuronal and time-segmental) to extract information from spike trains during the same total neuron-seconds. In the multineuronal vectorizing procedure, we defined a response vector whose components represented the spike counts of one to five neurons. In the time-segmental vectorizing procedure, a response vector consisted of components representing a neuron's spike counts for one to five time-segment(s) of a response period of 1 s. Spike trains were recorded from neurons in the inferior temporal cortex of monkeys presented with visual stimuli. We examined whether the amount of information of the visual stimuli carried by these neurons differed between the two vectorizing procedures. The amount of information calculated with the multineuronal vectorizing procedure, but not the time-segmental vectorizing procedure, significantly increased with the dimensions of the response vector. We conclude that the multineuronal vectorizing procedure is superior to the time-segmental vectorizing procedure in efficiently extracting information from neuronal signals. Copyright (c) 2010 Elsevier Ltd. All rights reserved.
Emerging surgical therapy in the treatment of glaucoma.
Nardi, Marco; Casini, Giamberto; Guidi, Gianluca; Figus, Michele
2015-01-01
There is general consensus that surgery gives a better intraocular pressure (IOP) control than medical therapy, but surgery may be affected by complications and failures, and for this reason nowadays, it is reserved to advanced or clearly progressive glaucoma. In recent years, there have been a lot of efforts to enhance safety and efficacy of conventional surgery as to find new techniques more safer and more effective. Actually, this is a field in rapid evolution, and we have a great number of innovative procedures, often working on complete different basis. These procedures are classified according to their mechanism of action and the type of surgical approach, in order to clearly understand of what we are speaking about. From a general point of view, surgical procedures may be divided in procedures that increase outflow and procedures that reduce aqueous production: most of these procedures can be performed with an ab externo or an ab interno approach. The ab interno approach has great advantages and enormous potential of development; probably, its diffusion will be facilitated by the development of new devices for angle visualization. Nevertheless, it is important to remember that actually none of the new procedures has been validated in large controlled clinical trials and none of the new procedures is indicated when IOP target is very low. © 2015 Elsevier B.V. All rights reserved.
A Hybrid Procedural/Deductive Executive for Autonomous Spacecraft
NASA Technical Reports Server (NTRS)
Pell, Barney; Gamble, Edward B.; Gat, Erann; Kessing, Ron; Kurien, James; Millar, William; Nayak, P. Pandurang; Plaunt, Christian; Williams, Brian C.; Lau, Sonie (Technical Monitor)
1998-01-01
The New Millennium Remote Agent (NMRA) will be the first AI system to control an actual spacecraft. The spacecraft domain places a strong premium on autonomy and requires dynamic recoveries and robust concurrent execution, all in the presence of tight real-time deadlines, changing goals, scarce resource constraints, and a wide variety of possible failures. To achieve this level of execution robustness, we have integrated a procedural executive based on generic procedures with a deductive model-based executive. A procedural executive provides sophisticated control constructs such as loops, parallel activity, locks, and synchronization which are used for robust schedule execution, hierarchical task decomposition, and routine configuration management. A deductive executive provides algorithms for sophisticated state inference and optimal failure recover), planning. The integrated executive enables designers to code knowledge via a combination of procedures and declarative models, yielding a rich modeling capability suitable to the challenges of real spacecraft control. The interface between the two executives ensures both that recovery sequences are smoothly merged into high-level schedule execution and that a high degree of reactivity is retained to effectively handle additional failures during recovery.
A Comparison of Exposure Control Procedures in CATS Using the GPC Model
ERIC Educational Resources Information Center
Leroux, Audrey J.; Dodd, Barbara G.
2016-01-01
The current study compares the progressive-restricted standard error (PR-SE) exposure control method with the Sympson-Hetter, randomesque, and no exposure control (maximum information) procedures using the generalized partial credit model with fixed- and variable-length CATs and two item pools. The PR-SE method administered the entire item pool…
ERIC Educational Resources Information Center
Brino, Ana Leda F., Barros, Romariz S., Galvao, Ol; Garotti, M.; Da Cruz, Ilara R. N.; Santos, Jose R.; Dube, William V.; McIlvane, William J.
2011-01-01
This paper reports use of sample stimulus control shaping procedures to teach arbitrary matching-to-sample to 2 capuchin monkeys ("Cebus apella"). The procedures started with identity matching-to-sample. During shaping, stimulus features of the sample were altered gradually, rendering samples and comparisons increasingly physically dissimilar. The…
47 CFR 1.9010 - De facto control standard for spectrum leasing arrangements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 1 2011-10-01 2011-10-01 false De facto control standard for spectrum leasing... PROCEDURE Spectrum Leasing General Policies and Procedures § 1.9010 De facto control standard for spectrum..., the following standard is applied for purposes of determining whether a licensee retains de facto...
47 CFR 1.9010 - De facto control standard for spectrum leasing arrangements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false De facto control standard for spectrum leasing... PROCEDURE Spectrum Leasing General Policies and Procedures § 1.9010 De facto control standard for spectrum..., the following standard is applied for purposes of determining whether a licensee retains de facto...
Behavior Modification of Studying Through Study Skills Advice and Self-Control Procedures
ERIC Educational Resources Information Center
Richards, C. Steven
1975-01-01
Investigates the efficacy of two behavioral self-control procedures as additions to the typical treatment for college students' study behavior--study skills advice. Predicted self-monitoring would be an effective treatment addition to study skills advice and study skills advice would be superior to the control groups. Results supported…
Ropkins, K; Beck, A J
2002-08-01
Hazard analysis by critical control points (HACCP) is a systematic approach to the identification, assessment and control of hazards. Effective HACCP requires the consideration of all hazards, i.e., chemical, microbiological and physical. However, to-date most 'in-place' HACCP procedures have tended to focus on the control of microbiological and physical food hazards. In general, the chemical component of HACCP procedures is either ignored or limited to applied chemicals, e.g., food additives and pesticides. In this paper we discuss the application of HACCP to a broader range of chemical hazards, using organic chemical contaminants as examples, and the problems that are likely to arise in the food manufacturing sector. Chemical HACCP procedures are likely to result in many of the advantages previously identified for microbiological HACCP procedures: more effective, efficient and economical than conventional end-point-testing methods. However, the high costs of analytical monitoring of chemical contaminants and a limited understanding of formulation and process optimisation as means of controlling chemical contamination of foods are likely to prevent chemical HACCP becoming as effective as microbiological HACCP.
The National Assessment Approach to Objectives and Exercise Development.
ERIC Educational Resources Information Center
Ward, Barbara
The National Assessment of Educational Progress (NAEP) item development procedures, possible improvements or alternatives to these procedures, and methods used to control potential sources of errors of interpretation are described. Current procedures call for the assessment of 9-, 13- and 17-year-olds in subject areas typically taught in schools.…
42 CFR 423.171 - Procedures for approval of accreditation as a basis for deeming compliance.
Code of Federal Regulations, 2010 CFR
2010-10-01
... BENEFIT Cost Control and Quality Improvement Requirements § 423.171 Procedures for approval of... 42 Public Health 3 2010-10-01 2010-10-01 false Procedures for approval of accreditation as a basis for deeming compliance. 423.171 Section 423.171 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES...
40 CFR Appendix B to Part 75 - Quality Assurance and Quality Control Procedures
Code of Federal Regulations, 2012 CFR
2012-07-01
... Systems 1.2.1Calibration Error Test and Linearity Check Procedures Keep a written record of the procedures used for daily calibration error tests and linearity checks (e.g., how gases are to be injected..., and when calibration adjustments should be made). Identify any calibration error test and linearity...
40 CFR Appendix B to Part 75 - Quality Assurance and Quality Control Procedures
Code of Federal Regulations, 2013 CFR
2013-07-01
... Systems 1.2.1Calibration Error Test and Linearity Check Procedures Keep a written record of the procedures used for daily calibration error tests and linearity checks (e.g., how gases are to be injected..., and when calibration adjustments should be made). Identify any calibration error test and linearity...
40 CFR 86.1360 - Supplemental emission test; test cycle and procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 19 2014-07-01 2014-07-01 false Supplemental emission test; test cycle and procedures. 86.1360 Section 86.1360 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Exhaust Test Procedures for Heavy-duty...
Code of Federal Regulations, 2010 CFR
2010-01-01
... organizational units of implementation and procedures. 23.7 Section 23.7 Commerce and Foreign Trade Office of the... Department of Commerce organizational units of implementation and procedures. Following are roles and...) Otherwise determine and control the use of missing children materials and information by the Operating Unit...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-08
..., 11.50, and 11.300) require the following standard operating procedures to assure appropriate use of... this regulation is a one-time burden associated with the creation of standard operating procedures... procedures and controls for persons who use closed systems to create, modify, maintain, or transmit...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-23
... Board (CARB) its request for a waiver of preemption for emission standards and related test procedures... standards and test procedures for heavy-duty urban bus engines and vehicles. The 2000 rulemaking included... to emission standards and test procedures resulting from these five sets of amendments were codified...
40 CFR 91.408 - Pre-test procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Pre-test procedures. 91.408 Section 91...) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.408 Pre-test... accordance with § 91.117. (b) Engine pre-test preparation. (1) Drain and charge the fuel tank(s) with the...
40 CFR 91.408 - Pre-test procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Pre-test procedures. 91.408 Section 91...) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.408 Pre-test... accordance with § 91.117. (b) Engine pre-test preparation. (1) Drain and charge the fuel tank(s) with the...
40 CFR 91.408 - Pre-test procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Pre-test procedures. 91.408 Section 91...) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.408 Pre-test... accordance with § 91.117. (b) Engine pre-test preparation. (1) Drain and charge the fuel tank(s) with the...
40 CFR 91.408 - Pre-test procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Pre-test procedures. 91.408 Section 91...) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.408 Pre-test... accordance with § 91.117. (b) Engine pre-test preparation. (1) Drain and charge the fuel tank(s) with the...
40 CFR 91.408 - Pre-test procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Pre-test procedures. 91.408 Section 91...) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.408 Pre-test... accordance with § 91.117. (b) Engine pre-test preparation. (1) Drain and charge the fuel tank(s) with the...
40 CFR 86.135-12 - Dynamometer procedure.
Code of Federal Regulations, 2013 CFR
2013-07-01
... control of pre-selectable power settings may be set anytime prior to the beginning of the emissions test... Heavy-Duty Vehicles; Test Procedures § 86.135-12 Dynamometer procedure. (a) Overview. The dynamometer run consists of two tests, a “cold” start test, after a minimum 12-hour and a maximum 36-hour soak...
40 CFR 86.135-12 - Dynamometer procedure.
Code of Federal Regulations, 2014 CFR
2014-07-01
... control of pre-selectable power settings may be set anytime prior to the beginning of the emissions test... Heavy-Duty Vehicles; Test Procedures § 86.135-12 Dynamometer procedure. (a) Overview. The dynamometer run consists of two tests, a “cold” start test, after a minimum 12-hour and a maximum 36-hour soak...
22 CFR 46.5 - Hearing procedure before special inquiry officer.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 22 Foreign Relations 1 2013-04-01 2013-04-01 false Hearing procedure before special inquiry officer. 46.5 Section 46.5 Foreign Relations DEPARTMENT OF STATE VISAS CONTROL OF ALIENS DEPARTING FROM THE UNITED STATES § 46.5 Hearing procedure before special inquiry officer. (a) The hearing before the...
22 CFR 46.5 - Hearing procedure before special inquiry officer.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 22 Foreign Relations 1 2012-04-01 2012-04-01 false Hearing procedure before special inquiry officer. 46.5 Section 46.5 Foreign Relations DEPARTMENT OF STATE VISAS CONTROL OF ALIENS DEPARTING FROM THE UNITED STATES § 46.5 Hearing procedure before special inquiry officer. (a) The hearing before the...
22 CFR 46.5 - Hearing procedure before special inquiry officer.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 22 Foreign Relations 1 2014-04-01 2014-04-01 false Hearing procedure before special inquiry officer. 46.5 Section 46.5 Foreign Relations DEPARTMENT OF STATE VISAS CONTROL OF ALIENS DEPARTING FROM THE UNITED STATES § 46.5 Hearing procedure before special inquiry officer. (a) The hearing before the...
22 CFR 46.5 - Hearing procedure before special inquiry officer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 22 Foreign Relations 1 2011-04-01 2011-04-01 false Hearing procedure before special inquiry officer. 46.5 Section 46.5 Foreign Relations DEPARTMENT OF STATE VISAS CONTROL OF ALIENS DEPARTING FROM THE UNITED STATES § 46.5 Hearing procedure before special inquiry officer. (a) The hearing before the...
30 CFR 250.1709 - What are my well-control fluid requirements?
Code of Federal Regulations, 2014 CFR
2014-07-01
... kill-weight fluid from the wellbore and/or riser to an underbalanced state, you must obtain approval... displacing the kill-weight fluid and provide detailed step-by-step written procedures describing how you will... barriers, (c) BOP procedures you will use while displacing kill weight fluids, and (d) Procedures you will...
30 CFR 250.514 - Well-control fluids, equipment, and operations.
Code of Federal Regulations, 2013 CFR
2013-07-01
... displace kill-weight fluid from the wellbore and/or riser to an underbalanced state, you must obtain... displacing the kill-weight fluid and provide detailed step-by-step written procedures describing how you will... barriers, (3) BOP procedures you will use while displacing kill-weight fluids, and (4) Procedures you will...
30 CFR 250.514 - Well-control fluids, equipment, and operations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... displace kill-weight fluid from the wellbore and/or riser to an underbalanced state, you must obtain... displacing the kill-weight fluid and provide detailed step-by-step written procedures describing how you will... barriers, (3) BOP procedures you will use while displacing kill-weight fluids, and (4) Procedures you will...
30 CFR 250.1709 - What are my well-control fluid requirements?
Code of Federal Regulations, 2013 CFR
2013-07-01
... kill-weight fluid from the wellbore and/or riser to an underbalanced state, you must obtain approval... displacing the kill-weight fluid and provide detailed step-by-step written procedures describing how you will... barriers, (c) BOP procedures you will use while displacing kill weight fluids, and (d) Procedures you will...
75 FR 38187 - Proposed Collection; Comment Request for Revenue Procedure 2007-48
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-01
... safe harbor method of accounting for rotable spare parts provided in the proposed revenue procedures... in Accounting Method. Current Actions: There are no changes being made to the revenue procedures at... OMB control number. Books or records relating to a collection of information must be retained as long...
The purpose of this SOP is to establish a uniform format for the preparation of SOPs. Use of these protocols ensures consistent implementation of project tasks, documents the preparation and implementation of the procedures used, describes quality control measures and the limits...
Mantziari, Lilian; Suman-Horduna, Irina; Gujic, Marko; Jones, David G; Wong, Tom; Markides, Vias; Foran, John P; Ernst, Sabine
2013-06-01
The impact of recently introduced asymmetric bidirectional ablation catheters on procedural parameters and acute success rates of ablation procedures is unknown. We retrospectively analyzed data regarding ablations using a novel bidirectional catheter in a tertiary cardiac center and compared these in 1:5 ratio with a control group of procedures matched for age, gender, operator, and ablation type. A total of 50 cases and 250 controls of median age 60 (50-68) years were studied. Structural heart disease was equally prevalent in both groups (39%) while history of previous ablations was more common in the study arm (54% vs 30%, P = 0.001). Most of the ablation cases were for atrial fibrillation (46%), followed by atrial tachycardia (28%), supraventricular tachycardia (12%), and ventricular tachycardia (14%). Median procedure duration was 128 (52-147) minutes with the bidirectional, versus 143 (105-200) minutes with the conventional catheter (P = 0.232), and median fluoroscopy time was 17 (10-34) minutes versus 23 (12-39) minutes, respectively (P = 0.988). There was a trend toward a lower procedure duration for the atrial tachycardia ablations, 89 (52-147) minutes versus 130 (100-210) minutes, P = 0.064. The procedure was successfully completed in 96% of the bidirectional versus 84% of the control cases (P = 0.151). A negative correlation was observed between the relative fluoroscopy duration and the case number (r = -0.312, P = 0.028), reflecting the learning curve for the bidirectional catheter. The introduction of the bidirectional catheter resulted in no prolongation of procedure parameters and similar success rates, while there was a trend toward a lower procedure duration for atrial tachycardia ablations. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.
Infection Rate after Cranial Neurosurgical Procedures: A Prospective Single-Center Study.
Strahm, Carol; Albrich, Werner C; Zdravkovic, Vilijam; Schöbi, Barbara; Hildebrandt, Gerhard; Schlegel, Matthias
2018-03-01
To determine infection rate (IR) and to identify modifiable risk factors (RF) in cranial neurosurgery in a neurosurgical department for tertiary referral as part of an infection control surveillance to reduce surgical site infections (SSI). A prospective SSI incidence cohort study from February 2013 to January 2014 was performed in a tertiary-care neurosurgical teaching hospital and referral center. All consecutive adults undergoing any cranial neurosurgical procedure were included. Data were collected by a trained member of the infection control staff during the twice-weekly visits of the hospitalized patients. Follow-up was 30 days (procedures without implant) and 1 year (procedures involving permanent implants). SSI was diagnosed according to criteria of CDC. A total of 317 patients undergoing 333 index procedures were included. The median age was 61 years (range, 17-91 years) and 46% were female. Survival in patients with completed follow-up was 76% (196/258). Overall, IR was 7.2% (24/333 index procedures); in 96% (23/24), a neurosurgical implant was involved. The IR of extraventricular drainage (EVD) was 12.5% (13.1/1000 EVD days). The main causative pathogens were Staphylococcus aureus followed by coagulase-negative staphylococci and Propionibacterium acnes. Independent RF for neurosurgical SSI were EVD as part of the index operation and body mass index >25 kg/m 2 . IR was in accordance with recent prospective single-center studies (reported IR between 1.6% and 9%). EVD placement was identified as the strongest modifiable RF for SSI in cranial neurosurgical procedures. The need for standard infection control procedures for the insertion and maintenance of EVDs to avoid their contamination is reinforced. Copyright © 2017 Elsevier Inc. All rights reserved.
Gerson, Lauren; Stouch, Bruce; Lobonţiu, Adrian
2018-01-01
The TIF procedure has emerged as an endoscopic treatment for patients with refractory gastro-esophageal reflux disease (GERD). Previous systematic reviews of the TIF procedure conflated findings from studies with modalities that do not reflect the current 2.0 procedure technique or refined data-backed patient selection criteria. A meta-analysis was conducted using data only from randomized studies that assessed the TIF 2.0 procedure compared to a control. The purpose of the meta-analysis was to determine the efficacy and long-term outcomes associated with performance of the TIF 2.0 procedure in patients with chronic long-term refractory GERD on optimized PPI therapy, including esophageal pH, PPI utilization and quality of life. Methods: Three prospective research questions were predicated on the outcomes of the TIF procedure compared to patients who received PPI therapy or sham, concomitant treatment for GERD, and the patient-reported quality of life. Event rates were calculated using the random effect model. Since the time of follow-up post-TIF procedure was variable, analysis was performed to incorporate the time of follow-up for each individual patient at the 3-year time point. Results: Results from this meta-analysis, including data from 233 patients, demonstrated that TIF subjects at 3 years had improved esophageal pH, a decrease in PPI utilization, and improved quality of life. Conclusions: In a meta-analysis of randomized, controlled trials (RCTs), the TIF procedure data for patients with GERD refractory to PPI's produces significant changes, compared with sham or PPI therapy, in esophageal pH, decreased PPI utilization, and improved quality of life. Celsius.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lutjeboer, Jacob, E-mail: j.lutjeboer@lumc.nl; Burgmans, Mark Christiaan, E-mail: m.c.burgmans@lumc.nl, E-mail: mburgmans@hotmail.com; Chung, Kaman, E-mail: kaman.chung10@gmail.com
PurposeInterventional radiology (IR) procedures are associated with high rates of preparation and planning errors. In many centers, pre-procedural consultation and screening of patients is performed by referring physicians. Interventional radiologists have better knowledge about procedure details and risks, but often only get acquainted with the patient in the procedure room. We hypothesized that patient safety (PS) and patient satisfaction (PSAT) in elective IR procedures would improve by implementation of a pre-procedural visit to an outpatient IR clinic.Material and MethodsIRB approval was obtained and informed consent was waived. PS and PSAT were measured in patients undergoing elective IR procedures before (controlmore » group; n = 110) and after (experimental group; n = 110) implementation of an outpatient IR clinic. PS was measured as the number of process deviations. PSAT was assessed using a questionnaire measuring Likert scores of three dimensions: interpersonal care aspects, information/communication, and patient participation. Differences in PS and PSAT between the two groups were compared using an independent t test.ResultsThe average number of process deviations per patient was 0.39 in the control group compared to 0.06 in the experimental group (p < 0.001). In 9.1 % patients in the control group, no legal informed consent was obtained compared to 0 % in the experimental group. The mean overall Likert score was significantly higher in the experimental group compared to the control group: 2.68 (SD 0.314) versus 2.48 (SD 0.381) (p < 0.001).ConclusionPS and PSAT improve significantly if patients receive consultation and screening in an IR outpatient clinic prior to elective IR procedures.« less
Reijnen, Michel M P J; Zeebregts, Clark J; Meijerink, Wilhelmus J H J
2005-01-01
Operating-room design has not changed significantly since the modern era of surgery began. Minimal invasive, endoscopic, procedures, and evolution of technology will affect operating-room design in the near future. Poor ergonomics has always been one of the major drawbacks of endoscopic surgery. Use of retractable arms and monitors will improve ergonomics of the operating team. Developments in telecommunication will allow surgeons to communicate with colleagues and experts during the procedure in virtually any location around the world, which increases teaching possibilities and procedural safety. Introduction and further development of intraoperative imaging, including real-time, three-dimensional (3-D) reconstructions of patient, and computer-aided surgery offer surgeons the opportunity to train the planned surgical procedure. Moreover, they will improve control and supervision of the procedure in learning situations. The last decade's robotics have made their introduction into the operating rooms. They improve control over the operating-room environment and will facilitate the performance of more complex procedures. However, high costs and lack of force feedback remain its major drawbacks. Improvements of robotic techniques and its implementation into the operating rooms will further guide their design into highly specialized operating units.
21 CFR 106.30 - Finished product evaluation.
Code of Federal Regulations, 2013 CFR
2013-04-01
... FOR HUMAN CONSUMPTION INFANT FORMULA QUALITY CONTROL PROCEDURES Quality Control Procedures for... maintenance of nutrient content throughout the shelf life of the product. (c) The manufacturer shall evaluate... the biological quality of the protein. A protein biological quality analysis is not necessary for a...
21 CFR 106.30 - Finished product evaluation.
Code of Federal Regulations, 2011 CFR
2011-04-01
... FOR HUMAN CONSUMPTION INFANT FORMULA QUALITY CONTROL PROCEDURES Quality Control Procedures for... maintenance of nutrient content throughout the shelf life of the product. (c) The manufacturer shall evaluate... the biological quality of the protein. A protein biological quality analysis is not necessary for a...
21 CFR 106.30 - Finished product evaluation.
Code of Federal Regulations, 2012 CFR
2012-04-01
... FOR HUMAN CONSUMPTION INFANT FORMULA QUALITY CONTROL PROCEDURES Quality Control Procedures for... maintenance of nutrient content throughout the shelf life of the product. (c) The manufacturer shall evaluate... the biological quality of the protein. A protein biological quality analysis is not necessary for a...
21 CFR 106.30 - Finished product evaluation.
Code of Federal Regulations, 2010 CFR
2010-04-01
... FOR HUMAN CONSUMPTION INFANT FORMULA QUALITY CONTROL PROCEDURES Quality Control Procedures for... maintenance of nutrient content throughout the shelf life of the product. (c) The manufacturer shall evaluate... the biological quality of the protein. A protein biological quality analysis is not necessary for a...
PROCEDURE FOR ESTIMATING PERMANENT TOTAL ENCLOSURE COSTS
The paper discusses a procedure for estimating permanent total enclosure (PTE) costs. (NOTE: Industries that use add-on control devices must adequately capture emissions before delivering them to the control device. One way to capture emissions is to use PTEs, enclosures that mee...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Procedures. 539.801 Section 539.801 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY WEAPONS OF MASS DESTRUCTION TRADE CONTROL REGULATIONS...
Evaluation of the FAA Advanced Flow Control Procedures.
DOT National Transportation Integrated Search
1972-01-01
The report is an evaluation of the present FAA Advanced Flow Control Procedures (AFCP), based on data gathered from its implementation on February 5, 1971 and on a fast-time digital simulation of traffic feeding into the NY airports on that day. The ...
76 FR 61563 - Voluntary Surrender of Certificate of Registration
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-05
... 21 CFR Part 1301 Administrative practice and procedure, Drug traffic control, Security measures. 21 CFR Part 1309 Administrative practice and procedure, Drug traffic control, Exports, Imports, Security... DEPARTMENT OF JUSTICE Drug Enforcement Administration 21 CFR Parts 1301 and 1309 [Docket No. DEA...
48 CFR 1201.304 - Agency control and compliance procedures.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Agency control and compliance procedures. 1201.304 Section 1201.304 Federal Acquisition Regulations System DEPARTMENT OF TRANSPORTATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Agency Acquisition Regulations 1201.304 Agency...
48 CFR 401.304 - Agency control and compliance procedures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 4 2011-10-01 2011-10-01 false Agency control and compliance procedures. 401.304 Section 401.304 Federal Acquisition Regulations System DEPARTMENT OF AGRICULTURE GENERAL AGRICULTURE ACQUISITION REGULATION SYSTEM Agency Acquisition Regulations 401.304 Agency...
HANDBOOK: QUALITY ASSURANCE/QUALITY CONTROL (QA/QC) PROCEDURES FOR HAZARDOUS WASTE INCINERATION
Resource Conservation and Recovery Act regulations for hazardous waste incineration require trial burns by permit applicants. uality Assurance Project Plan (QAPjP) must accompany a trial burn plan with appropriate quality assurance/quality control procedures. uidance on the prepa...
48 CFR 401.304 - Agency control and compliance procedures.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Agency control and compliance procedures. 401.304 Section 401.304 Federal Acquisition Regulations System DEPARTMENT OF AGRICULTURE GENERAL AGRICULTURE ACQUISITION REGULATION SYSTEM Agency Acquisition Regulations 401.304 Agency...
Acceptance Test Procedure for New Pumping Instrumentation and Control Skid Q
DOE Office of Scientific and Technical Information (OSTI.GOV)
KOCH, M.R.
2000-03-27
This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''Q''. The ATP will be performed after the construction of the PIC skid in the fabrication shop.
PC based temporary shielding administrative procedure (TSAP)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Olsen, D.E.; Pederson, G.E.; Hamby, P.N.
1995-03-01
A completely new Administrative Procedure for temporary shielding was developed for use at Commonwealth Edison`s six nuclear stations. This procedure promotes the use of shielding, and addresses industry requirements for the use and control of temporary shielding. The importance of an effective procedure has increased since more temporary shielding is being used as ALARA goals become more ambitious. To help implement the administrative procedure, a personal computer software program was written to incorporate the procedural requirements. This software incorporates the useability of a Windows graphical user interface with extensive help and database features. This combination of a comprehensive administrative proceduremore » and user friendly software promotes the effective use and management of temporary shielding while ensuring that industry requirements are met.« less
Sriratanaviriyakul, Narin; Kivler, Celeste; Vidovszky, Tamas J; Yoneda, Ken Y; Kenyon, Nicholas J; Murin, Susan; Louie, Samuel
2016-05-24
Gastroesophageal reflux disease is one of the most common comorbidities in patients with asthma. Gastroesophageal reflux disease can be linked to difficult-to-control asthma. Current management includes gastric acid suppression therapy and surgical antireflux procedures. The LINX® procedure is a novel surgical treatment for patients with gastroesophageal reflux disease refractory to medical therapy. To the best of our knowledge, we report the first case of successful treatment of refractory asthma secondary to gastroesophageal reflux disease using the LINX® procedure. Our patient was a 22-year-old white woman who met the American Thoracic Society criteria for refractory asthma that had remained poorly controlled for 5 years despite progressive escalation to step 6 treatment as recommended by National Institutes of Health-National Asthma Education and Prevention Program guidelines, including high-dose oral corticosteroids, high-dose inhaled corticosteroid plus long-acting β2-agonist, leukotriene receptor antagonist, and monthly omalizumab. Separate trials with azithromycin therapy and roflumilast did not improve her asthma control, nor did bronchial thermoplasty help. Additional consultations with two other university health systems left the patient with few treatment options for asthma, which included cyclophosphamide. Instead, the patient underwent a LINX® procedure after failure of maximal medical therapy for gastroesophageal reflux disease with the additional aim of improving asthma control. After she underwent LINX® treatment, her asthma improved dramatically and was no longer refractory. She had normal exhaled nitric oxide levels and loss of peripheral eosinophilia after LINX® treatment. Prednisone was discontinued without loss of asthma control. The only immediate adverse effects due to the LINX® procedure were bloating, nausea, and vomiting. LINX® is a viable alternative to the Nissen fundoplication procedure for the treatment of patients with gastroesophageal reflux disease and poorly controlled concomitant refractory asthma.
NASA Technical Reports Server (NTRS)
Stetson, Howard K.; Haddock, Angie T.; Frank, Jeremy; Cornelius, Randy; Wang, Lui; Garner, Larry
2015-01-01
NASA is investigating a range of future human spaceflight missions, including both Mars-distance and Near Earth Object (NEO) targets. Of significant importance for these missions is the balance between crew autonomy and vehicle automation. As distance from Earth results in increasing communication delays, future crews need both the capability and authority to independently make decisions. However, small crews cannot take on all functions performed by ground today, and so vehicles must be more automated to reduce the crew workload for such missions. NASA's Advanced Exploration Systems Program funded Autonomous Mission Operations (AMO) project conducted an autonomous command and control experiment on-board the International Space Station that demonstrated single action intelligent procedures for crew command and control. The target problem was to enable crew initialization of a facility class rack with power and thermal interfaces, and involving core and payload command and telemetry processing, without support from ground controllers. This autonomous operations capability is enabling in scenarios such as initialization of a medical facility to respond to a crew medical emergency, and representative of other spacecraft autonomy challenges. The experiment was conducted using the Expedite the Processing of Experiments for Space Station (EXPRESS) rack 7, which was located in the Port 2 location within the U.S Laboratory onboard the International Space Station (ISS). Activation and deactivation of this facility is time consuming and operationally intensive, requiring coordination of three flight control positions, 47 nominal steps, 57 commands, 276 telemetry checks, and coordination of multiple ISS systems (both core and payload). Utilization of Draper Laboratory's Timeliner software, deployed on-board the ISS within the Command and Control (C&C) computers and the Payload computers, allowed development of the automated procedures specific to ISS without having to certify and employ novel software for procedure development and execution. The procedures contained the ground procedure logic and actions as possible to include fault detection and recovery capabilities. The autonomous operations concept includes a reduction of the amount of data a crew operator is required to verify during activation or de-activation, as well as integration of procedure execution status and relevant data in a single integrated display. During execution, the auto-procedures (via Timerliner) provide a step-by-step messaging paradigm and a high-level status upon termination. This messaging and high-level status is the only data generated for operator display. To enhance situational awareness of the operator, the Web-based Procedure Display (WebPD) provides a novel approach to the issues of procedure display and execution tracking. WebPD is a web based application that serves as the user interface for electronic procedure execution. It incorporates several aspects of the HTML5 standard. Procedures are written in a dialect of XML called Procedure Representation Language (PRL). WebPD tracks execution status in the procedure or procedures being displayed. WebPD aggregates and simplifies the auto-sequence execution status information, and formatted to be easily followed and understood by an operator who is not dedicated to actively monitoring the task. WebPD also provides an integrated data and control interface to pause or halt the execution in order to provide a check point of operation and to examine progress before starting the next sequence of activities. For this demonstration, the procedure was initiated and monitored from the ground. As the Timeliner sequences executed, their high-level execution status was written to PLMDM memory. This memory is read and downlinked via Ku-Band at a 1 Hz rate. The data containing the high-level execution status is de-commutated on the ground, and rebroadcast for WebPD consumption. A future demonstration will be performed onboard, with ISS astronauts initiating the operations instead of ground controllers. The AMO EXPRESS experiment demonstrated activation and de-activation of EXPRESS rack 7, providing the capability of future single button activations and deactivations of facility class racks. The experiment achieved numerous technical and operations 'firsts' for the ISS
NASA Technical Reports Server (NTRS)
Wells, S. R.; Hess, R. A.
2002-01-01
A frequency-domain procedure for the design of sliding mode controllers for multi-input, multi-output (MIMO) systems is presented. The methodology accommodates the effects of parasitic dynamics such as those introduced by unmodeled actuators through the introduction of multiple asymptotic observers and model reference hedging. The design procedure includes a frequency domain approach to specify the sliding manifold, the observer eigenvalues, and the hedge model. The procedure is applied to the development of a flight control system for a linear model of the Innovative Control Effector (ICE) fighter aircraft. The stability and performance robustness of the resulting design is demonstrated through the introduction of significant degradation in the control effector actuators and variation in vehicle dynamics.
Park, Woo Young; Shin, Yang-Sik; Lee, Sang Kil; Kim, So Yeon; Lee, Tai Kyung
2014-01-01
Purpose Endoscopic submucosal dissection (ESD) is a technically difficult and lengthy procedure requiring optimal depth of sedation. The bispectral index (BIS) monitor is a non-invasive tool that objectively evaluates the depth of sedation. The purpose of this prospective randomized controlled trial was to evaluate whether BIS guided sedation with propofol and remifentanil could reduce the number of patients requiring rescue propofol, and thus reduce the incidence of sedation- and/or procedure-related complications. Materials and Methods A total of 180 patients who underwent the ESD procedure for gastric adenoma or early gastric cancer were randomized to two groups. The control group (n=90) was monitored by the Modified Observer's Assessment of Alertness and Sedation scale and the BIS group (n=90) was monitored using BIS. The total doses of propofol and remifentanil, the need for rescue propofol, and the rates of complications were recorded. Results The number of patients who needed rescue propofol during the procedure was significantly higher in the control group than the BIS group (47.8% vs. 30.0%, p=0.014). There were no significant differences in the incidence of sedation- and/or procedure-related complications. Conclusion BIS-guided propofol infusion combined with remifentanil reduced the number of patients requiring rescue propofol in ESD procedures. However, this finding did not lead to clinical benefits and thus BIS monitoring is of limited use during anesthesiologist-directed sedation. PMID:25048506
1983-05-01
Firing data cards. PROCEDURES I. Prior to live fire exercises all firers must be oriented on range procedures. 2. Preparatory marksmanship training...Ordnance detail. 2. Range safety officer. 7. Medical personnel. 3. Firing line safety NCOs. 8. Control tower operators. i 4. Scorer (I per firer ). 9. Pit...phones and wire (for PIT commo). PROCEDURES I. Prior to live fire exercises, all firers must be oriented on range procedures. 2. Scorers are responsible
Alternatives to the sequential lineup: the importance of controlling the pictures.
Lindsay, R C; Bellinger, K
1999-06-01
Because sequential lineups reduce false-positive choices, their use has been recommended (R. C. L. Lindsay, 1999; R. C. L. Lindsay & G. L. Wells, 1985). Blind testing is included in the recommended procedures. Police, concerned about blind testing, devised alternative procedures, including self-administered sequential lineups, to reduce use of relative judgments (G. L. Wells, 1984) while permitting the investigating officer to conduct the procedure. Identification data from undergraduates exposed to a staged crime (N = 165) demonstrated that 4 alternative identification procedures tested were less effective than the original sequential lineup. Allowing witnesses to control the photographs resulted in higher rates of false-positive identification. Self-reports of using relative judgments were shown to be postdictive of decision accuracy.
A cost and time analysis of laryngology procedures in the endoscopy suite versus the operating room.
Hillel, Alexander T; Ochsner, Matthew C; Johns, Michael M; Klein, Adam M
2016-06-01
To assess the costs, charges, reimbursement, and efficiency of performing awake laryngology procedures in an endoscopy suite (ES) compared with like procedures performed in the operating room (OR). Retrospective review of billing records. Cost, charges, and reimbursements for the hospital, surgeon, and anesthesiologist were compared between ES injection laryngoplasty and laser excision procedures and matched case controls in the OR. Time spent in 1) the preoperative unit, 2) the operating or endoscopy suite, and 3) recovery unit were compared between OR and ES procedures. Hospital expenses were significantly less for ES procedures when compared to OR procedures. Reimbursement was similar for ES and OR injection laryngoplasty, though greater for OR laser excisions. Net balance (reimbursement-expenses) was greater for ES procedures. A predictive model of payer costs over a 3-year period showed similar costs for ES and OR laser procedures and reduced costs for ES compared to OR injection laryngoplasty. Times spent preoperatively and the procedure were significantly less for ES procedures. For individual laryngology procedures, the ES reduces time and costs compared to the OR, increasing otolaryngologist and hospital efficiency. This reveals cost and time savings of ES injection laryngoplasty, which occurs at a similar frequency as OR injection laryngoplasty. Given the increased frequency for ES laser procedures, total costs are similar for ES and OR laser excision of papilloma, which usually require repeated procedures. When regulated office space is unavailable, endoscopy rooms represent an alternative setting for unsedated laryngology procedures. NA Laryngoscope, 126:1385-1389, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.
42 CFR 476.160 - General quality of care review procedures.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 4 2013-10-01 2013-10-01 false General quality of care review procedures. 476.160... SERVICES (CONTINUED) QUALITY IMPROVEMENT ORGANIZATIONS UTILIZATION AND QUALITY CONTROL REVIEW Review Responsibilities of Utilization and Quality Control Quality Improvement Organizations (QIOs) Qio Review Functions...
Project #OA-FY17-0382, August 28, 2017. The EPA OIG plans to begin preliminary research on the EPA’s adherence to policies, procedures and oversight controls pertaining to the Administrator’s travel to Oklahoma.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 2 2013-04-01 2013-04-01 false Coding. 106.90 Section 106.90 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION INFANT FORMULA QUALITY CONTROL PROCEDURES Quality Control Procedures for Assuring Nutrient Content...
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 2 2011-04-01 2011-04-01 false Coding. 106.90 Section 106.90 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION INFANT FORMULA QUALITY CONTROL PROCEDURES Quality Control Procedures for Assuring Nutrient Content...
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 2 2012-04-01 2012-04-01 false Coding. 106.90 Section 106.90 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION INFANT FORMULA QUALITY CONTROL PROCEDURES Quality Control Procedures for Assuring Nutrient Content...
75 FR 32140 - Voluntary Surrender of Certificate of Registration
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-07
... 21 CFR Part 1301 Administrative practice and procedure, Drug traffic control, Security measures. 21 CFR Part 1309 Administrative practice and procedure, Drug traffic control, Exports, Imports, Security... DEPARTMENT OF JUSTICE Drug Enforcement Administration 21 CFR Parts 1301, 1309 [Docket No. DEA-304P...
12 CFR 240.13 - Trading and operational standards.
Code of Federal Regulations, 2014 CFR
2014-01-01
... operational standards. (a) Internal rules, procedures, and controls required. A banking institution engaging in retail forex transactions shall establish and implement internal rules, procedures, and controls designed, at a minimum, to: (1) Ensure, to the extent reasonable, that each order received from a retail...
14 CFR 150.33 - Evaluation of programs.
Code of Federal Regulations, 2014 CFR
2014-01-01
...) AIRPORTS AIRPORT NOISE COMPATIBILITY PLANNING Evaluations and Determinations of Effects of Noise... additional noncompatible land uses; and (3) Include the use of new or modified flight procedures to control the operation of aircraft for purposes of noise control, or affect flight procedures in any way. (b...
14 CFR 150.33 - Evaluation of programs.
Code of Federal Regulations, 2013 CFR
2013-01-01
...) AIRPORTS AIRPORT NOISE COMPATIBILITY PLANNING Evaluations and Determinations of Effects of Noise... additional noncompatible land uses; and (3) Include the use of new or modified flight procedures to control the operation of aircraft for purposes of noise control, or affect flight procedures in any way. (b...
14 CFR 150.33 - Evaluation of programs.
Code of Federal Regulations, 2012 CFR
2012-01-01
...) AIRPORTS AIRPORT NOISE COMPATIBILITY PLANNING Evaluations and Determinations of Effects of Noise... additional noncompatible land uses; and (3) Include the use of new or modified flight procedures to control the operation of aircraft for purposes of noise control, or affect flight procedures in any way. (b...
14 CFR 150.33 - Evaluation of programs.
Code of Federal Regulations, 2011 CFR
2011-01-01
...) AIRPORTS AIRPORT NOISE COMPATIBILITY PLANNING Evaluations and Determinations of Effects of Noise... additional noncompatible land uses; and (3) Include the use of new or modified flight procedures to control the operation of aircraft for purposes of noise control, or affect flight procedures in any way. (b...
14 CFR 150.33 - Evaluation of programs.
Code of Federal Regulations, 2010 CFR
2010-01-01
...) AIRPORTS AIRPORT NOISE COMPATIBILITY PLANNING Evaluations and Determinations of Effects of Noise... additional noncompatible land uses; and (3) Include the use of new or modified flight procedures to control the operation of aircraft for purposes of noise control, or affect flight procedures in any way. (b...
42 CFR 493.1256 - Standard: Control procedures.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Systems § 493.1256 Standard: Control procedures. (a) For each test system, the laboratory is responsible... test system failure, adverse environmental conditions, and operator performance. (2) Monitor over time the accuracy and precision of test performance that may be influenced by changes in test system...
42 CFR 493.1256 - Standard: Control procedures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Systems § 493.1256 Standard: Control procedures. (a) For each test system, the laboratory is responsible... test system failure, adverse environmental conditions, and operator performance. (2) Monitor over time the accuracy and precision of test performance that may be influenced by changes in test system...
42 CFR 493.1256 - Standard: Control procedures.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Systems § 493.1256 Standard: Control procedures. (a) For each test system, the laboratory is responsible... test system failure, adverse environmental conditions, and operator performance. (2) Monitor over time the accuracy and precision of test performance that may be influenced by changes in test system...
42 CFR 493.1256 - Standard: Control procedures.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Systems § 493.1256 Standard: Control procedures. (a) For each test system, the laboratory is responsible... test system failure, adverse environmental conditions, and operator performance. (2) Monitor over time the accuracy and precision of test performance that may be influenced by changes in test system...
40 CFR 35.6270 - Standards for financial management systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... § 35.6270 Standards for financial management systems. (a) Accounting system standards—(1) General. The... Agreement. (6) Accounting system control procedures. Except as provided for in paragraph (a)(3) of this section, accounting system control procedures must ensure that accounting information is: (i) Accurate...
Virtual reality distraction for pain control during periodontal scaling and root planing procedures.
Furman, Elena; Jasinevicius, T Roma; Bissada, Nabil F; Victoroff, Kristin Z; Skillicorn, Robert; Buchner, Marc
2009-12-01
Although pain management during periodontal treatment usually is achieved with anesthesia, alternative methods are available. The authors conducted a study to evaluate the analgesic effect of immersive virtual reality (VR) during periodontal scaling and root planing (SRP) procedures. The authors recruited 38 patients. They used a within-patient/split-mouth design. Patients received SRP under three treatment conditions in three quadrants. The three conditions were control, watching a movie and VR. After each SRP procedure, patients responded to questions about their discomfort and/or pain by using a visual analog scale (VAS) (range, 0 to 10 in which lower numbers indicate less pain or discomfort). The authors also recorded patients' blood pressure (BP) and pulse rate (PR). Patients were asked which of the three treatment modalities they preferred. The mean (+/- standard deviation) VAS scores for five questions pertaining to control, movie and VR were 3.95 +/- 2.1, 2.57 +/- 1.8 and 1.76 +/- 1.4, respectively. Paired t tests revealed that VAS scores were significantly lower during VR compared with the movie (P <.001) and control (P <.001) conditions. Similarly, BP and PR were lowest during VR, followed by the movie and control conditions. Patients reported that they preferred the VR condition. The results of this study suggest that use of immersive VR distraction may be an effective method of pain control during SRP procedures. Practitioners can use immersive VR distraction for pain control during SRP procedures.
Kluge, Annette; Grauel, Britta; Burkolter, Dina
2013-03-01
Two studies are presented in which the design of a procedural aid and the impact of an additional decision aid for process control were assessed. In Study 1, a procedural aid was developed that avoids imposing unnecessary extraneous cognitive load on novices when controlling a complex technical system. This newly designed procedural aid positively affected germane load, attention, satisfaction, motivation, knowledge acquisition and diagnostic speed for novel faults. In Study 2, the effect of a decision aid for use before the procedural aid was investigated, which was developed based on an analysis of diagnostic errors committed in Study 1. Results showed that novices were able to diagnose both novel faults and practised faults, and were even faster at diagnosing novel faults. This research contributes to the question of how to optimally support novices in dealing with technical faults in process control. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Simulation of time-control procedures for terminal area flow management
NASA Technical Reports Server (NTRS)
Alcabin, M.; Erzberger, H.; Tobias, L.; Obrien, P. J.
1985-01-01
Simulations of a terminal area traffic-management system incorporating automated scheduling and time-control (four-dimensional) techniques conducted at NASA Ames Research Center jointly with the Federal Aviation Administration, have shown that efficient procedures can be developed for handling a mix of 4D-equipped and conventionally equipped aircraft. A crucial role in this system is played by an ATC host computer algorithm, referred to as a speed advisory, that allows controllers to maintain accurate time schedules of the conventionally equipped aircraft in the traffic mix. Results are of the most recent simulations in which two important special cases were investigated. First, the effects of a speed advisory on touchdown time scheduling are examined, when unequipped aircraft are constrained to follow fuel-optimized profiles in the near-terminal area, and rescheduling procedures are developed to handle missed approaches of 4D-equipped aircraft. Various performance measures, including controller opinion, are used to evaluate the effectiveness of the procedures.
Hierarchical control of procedural and declarative category-learning systems
Turner, Benjamin O.; Crossley, Matthew J.; Ashby, F. Gregory
2017-01-01
Substantial evidence suggests that human category learning is governed by the interaction of multiple qualitatively distinct neural systems. In this view, procedural memory is used to learn stimulus-response associations, and declarative memory is used to apply explicit rules and test hypotheses about category membership. However, much less is known about the interaction between these systems: how is control passed between systems as they interact to influence motor resources? Here, we used fMRI to elucidate the neural correlates of switching between procedural and declarative categorization systems. We identified a key region of the cerebellum (left Crus I) whose activity was bidirectionally modulated depending on switch direction. We also identified regions of the default mode network (DMN) that were selectively connected to left Crus I during switching. We propose that the cerebellum—in coordination with the DMN—serves a critical role in passing control between procedural and declarative memory systems. PMID:28213114
Examining procedural working memory processing in obsessive-compulsive disorder.
Shahar, Nitzan; Teodorescu, Andrei R; Anholt, Gideon E; Karmon-Presser, Anat; Meiran, Nachshon
2017-07-01
Previous research has suggested that a deficit in working memory might underlie the difficulty of obsessive-compulsive disorder (OCD) patients to control their thoughts and actions. However, a recent meta-analyses found only small effect sizes for working memory deficits in OCD. Recently, a distinction has been made between declarative and procedural working memory. Working memory in OCD was tested mostly using declarative measurements. However, OCD symptoms typically concerns actions, making procedural working-memory more relevant. Here, we tested the operation of procedural working memory in OCD. Participants with OCD and healthy controls performed a battery of choice reaction tasks under high and low procedural working memory demands. Reaction-times (RT) were estimated using ex-Gaussian distribution fitting, revealing no group differences in the size of the RT distribution tail (i.e., τ parameter), known to be sensitive to procedural working memory manipulations. Group differences, unrelated to working memory manipulations, were found in the leading-edge of the RT distribution and analyzed using a two-stage evidence accumulation model. Modeling results suggested that perceptual difficulties might underlie the current group differences. In conclusion, our results suggest that procedural working-memory processing is most likely intact in OCD, and raise a novel, yet untested assumption regarding perceptual deficits in OCD. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.
Acute normovolemic hemodilution is safe in neurosurgery.
Oppitz, Paulo P; Stefani, Marco A
2013-01-01
To determine the safety of acute normovolemic hemodilution (ANH) for patients undergoing neurosurgical procedures. A group of 100 patients undergoing neurosurgical procedures was assigned prospectively to receive ANH. A group of 47 patients who underwent craniotomy for aneurysm clipping and standard anesthetic management was used as a control. Procedures conducted under ANH were performed without significant variations in physiologic parameters. Compared with controls, intraoperative blood loss, operative time, incidence and grade of complications, and length of hospital stay were similar between the two groups. Although the ANH group showed a difference in prothrombin levels before and after hemodilution procedures, the levels were still considered within physiologic parameters. Platelet counts and partial thromboplastin time (PTT) levels indicated no significant variations in either group. During the ANH procedure, a considerable reduction of brain oxygen extraction was observed in individuals with worse preoperative neurologic status (P < 0.05), indicating potential benefit. Among patients with cerebral aneurysm, patients with good initial clinical grades had better clinical results as indicated by Glasgow Outcome Scale scores (P < 0.02). ANH is a safe procedure for patients undergoing neurosurgical procedures. Further studies are necessary to confirm the improvement in brain oxygen extraction and the clinical impact. Nonetheless, patients undergoing aneurysm clipping with good clinical grades seem to profit from ANH. Copyright © 2013 Elsevier Inc. All rights reserved.
Comparison of hand hygiene procedures for removing Bacillus cereus spores.
Sasahara, Teppei; Hayashi, Shunji; Hosoda, Kouichi; Morisawa, Yuji; Hirai, Yoshikazu
2014-01-01
Bacillus cereus is a spore-forming bacterium. B. cereus occasionally causes nosocomial infections, in which hand contamination with the spores plays an important role. Therefore, hand hygiene is the most important practice for controlling nosocomial B. cereus infections. This study aimed to determine the appropriate hand hygiene procedure for removing B. cereus spores. Thirty volunteers' hands were experimentally contaminated with B. cereus spores, after which they performed 6 different hand hygiene procedures. We compared the efficacy of the procedures in removing the spores from hands. The alcohol-based hand-rubbing procedures scarcely removed them. The soap washing procedures reduced the number of spores by more than 2 log10. Extending the washing time increased the spore-removing efficacy of the washing procedures. There was no significant difference in efficacy between the use of plain soap and antiseptic soap. Handwashing with soap is appropriate for removing B. cereus spores from hands. Alcohol-based hand-rubbing is not effective.
Particulate Matter Stack Emission Compliance Test Procedure for Fuel Burning Units.
ERIC Educational Resources Information Center
West Virginia Air Pollution Control Commission, Charleston.
This publication details the particulate matter emissions test procedure that is applicable for conducting compliance tests for fuel burning units required to be tested under Sub-section 7 of Regulation II (1972) as established by the state of West Virginia Air Pollution Control Commission. The testing procedure is divided into five parts:…
The purpose of this SOP is to establish a uniform format for the preparation of SOPs. Use of these protocols ensures consistent implementation of project tasks, documents the preparation and implementation of the procedures used, describes quality control measures and the limits...
12 CFR 225.43 - Procedures for filing, processing, publishing, and acting on notices.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 12 Banks and Banking 3 2010-01-01 2010-01-01 false Procedures for filing, processing, publishing... (REGULATION Y) Regulations Change in Bank Control § 225.43 Procedures for filing, processing, publishing, and.... Any person(s) filing a notice under this subpart shall publish, in a form prescribed by the Board, an...
21 CFR 1305.12 - Procedure for executing DEA Forms 222.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 9 2010-04-01 2010-04-01 false Procedure for executing DEA Forms 222. 1305.12... I AND II CONTROLLED SUBSTANCES DEA Form 222 § 1305.12 Procedure for executing DEA Forms 222. (a) A purchaser must prepare and execute a DEA Form 222 simultaneously in triplicate by means of interleaved...
21 CFR 1305.11 - Procedure for obtaining DEA Forms 222.
Code of Federal Regulations, 2010 CFR
2010-04-01
... the name, address, and registration number of the registrant and the number of books of DEA Forms 222... 21 Food and Drugs 9 2010-04-01 2010-04-01 false Procedure for obtaining DEA Forms 222. 1305.11... I AND II CONTROLLED SUBSTANCES DEA Form 222 § 1305.11 Procedure for obtaining DEA Forms 222. (a) DEA...
21 CFR 1305.12 - Procedure for executing DEA Forms 222.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 9 2011-04-01 2011-04-01 false Procedure for executing DEA Forms 222. 1305.12... I AND II CONTROLLED SUBSTANCES DEA Form 222 § 1305.12 Procedure for executing DEA Forms 222. (a) A purchaser must prepare and execute a DEA Form 222 simultaneously in triplicate by means of interleaved...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 1 2010-10-01 2010-10-01 false What procedures must the Secretary follow if the... What procedures must the Secretary follow if the Secretary rejects a final construction project... controlling legal authority supporting the rejection; (b) Within 20 days, provide all documents relied on in...
21 CFR 212.90 - What actions must I take to control the distribution of PET drug products?
Code of Federal Regulations, 2010 CFR
2010-04-01
... distribution of PET drug products? 212.90 Section 212.90 Food and Drugs FOOD AND DRUG ADMINISTRATION... control the distribution of PET drug products? (a) Written distribution procedures. You must establish, maintain, and follow written procedures for the control of distribution of PET drug products shipped from...
Vernon, Howard; Triano, John T; Soave, David; Dinulos, Maricelle; Ross, Kim; Tran, Steven
2013-10-01
Participants in clinical trials of spinal manipulation have not been rigorously blinded to group assignment. This study reports on secondary analyses of the retention of participant blinding beyond the immediate posttreatment time frame following a single-session, randomized clinical study. A novel control cervical manipulation procedure that has previously been shown to be therapeutically inert was contrasted with a typical manipulation procedure. A randomized clinical study of a single session of typical vs sham-control manipulation in patients with chronic neck pain was conducted. Findings of self-reported group registration at 24 to 48 hours posttreatment were computed. The Blinding Index (BI) of Bang et al was then applied to both the immediate and post-24- to 48-hour results. Twenty-four to 48 hours after treatment, 94% and 22% of participants in the typical and control groups, respectively, correctly identified their group assignment. When analyzed with the BI of Bang et al, the immediate posttreatment BI for the group receiving a typical manipulation was 0.22 (95% confidence interval [CI], -0.03 to 0.47); for the group receiving a control manipulation, it was 0.19 (95% CI, -0.06 to 0.43). The BI at post-24 hours was as follows: typical = 0.75 (95% CI, 0.59-0.91) and control = -0.34 (95% CI, -0.58 to -0.11). This study found that the novel sham-control cervical manipulation procedure may be effective in blinding sham group allocation up to 48 hours posttreatment. It appears that, at 48 hours posttreatment, the modified form of the typical cervical manipulation was not. The sham-control procedure appears to be a promising procedure for future clinical trials. © 2013. Published by National University of Health Sciences All rights reserved.
Design, evaluation and test of an electronic, multivariable control for the F100 turbofan engine
NASA Technical Reports Server (NTRS)
Skira, C. A.; Dehoff, R. L.; Hall, W. E., Jr.
1980-01-01
A digital, multivariable control design procedure for the F100 turbofan engine is described. The controller is based on locally linear synthesis techniques using linear, quadratic regulator design methods. The control structure uses an explicit model reference form with proportional and integral feedback near a nominal trajectory. Modeling issues, design procedures for the control law and the estimation of poorly measured variables are presented.
78 FR 65718 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-01
... maintain certain risk management controls and supervisory procedures as well as regularly review such... supervisory procedures and a written description of its risk management controls as part of its books and... providing sponsored or direct market access to customers or other persons, to implement risk management...
75 FR 5351 - Proposed Revisions to Accounting Guide for LSC Recipients
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-02
... elements of an adequate accounting and financial reporting system, including the use of specific internal... checklist of accounting procedures and internal controls. The proposed revisions update the checklist to... accounting procedures and internal controls to reflect current best practices; (7) updated and new references...
Job-Seeking Interview Skills Training: A Comparison of Four Instructional Techniques.
ERIC Educational Resources Information Center
Speas, Carol Mendenhall
1979-01-01
Compared model exposure (MOD), role playing (RP), model exposure plus role playing (MRP), and model exposure role playing with videotape feedback (VIDEO). MRP and VIDEO treatments were greater than control procedures. RP treatment was more effective than control procedures on two criteria. (Author/BEF)
Modeling and control of tissue compression and temperature for automation in robot-assisted surgery.
Sinha, Utkarsh; Li, Baichun; Sankaranarayanan, Ganesh
2014-01-01
Robotic surgery is being used widely due to its various benefits that includes reduced patient trauma and increased dexterity and ergonomics for the operating surgeon. Making the whole or part of the surgical procedure autonomous increases patient safety and will enable the robotic surgery platform to be used in telesurgery. In this work, an Electrosurgery procedure that involves tissue compression and application of heat such as the coaptic vessel closure has been automated. A MIMO nonlinear model characterizing the tissue stiffness and conductance under compression was feedback linearized and tuned PID controllers were used to control the system to achieve both the displacement and temperature constraints. A reference input for both the constraints were chosen as a ramp and hold trajectory which reflect the real constraints that exist in an actual surgical procedure. Our simulations showed that the controllers successfully tracked the reference trajectories with minimal deviation and in finite time horizon. The MIMO system with controllers developed in this work can be used to drive a surgical robot autonomously and perform electrosurgical procedures such as coaptic vessel closures.
78 FR 33265 - Proposed Establishment of Class E Airspace; Umatilla, FL
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-04
...) Global Positioning System (GPS) Standard Instrument Approach Procedures at Umatilla Municipal Airport... (GPS) standard instrument approach procedures for Umatilla Municipal Airport. Controlled airspace...
Integrated flight/propulsion control - Subsystem specifications for performance
NASA Technical Reports Server (NTRS)
Neighbors, W. K.; Rock, Stephen M.
1993-01-01
A procedure is presented for calculating multiple subsystem specifications given a number of performance requirements on the integrated system. This procedure applies to problems where the control design must be performed in a partitioned manner. It is based on a structured singular value analysis, and generates specifications as magnitude bounds on subsystem uncertainties. The performance requirements should be provided in the form of bounds on transfer functions of the integrated system. This form allows the expression of model following, command tracking, and disturbance rejection requirements. The procedure is demonstrated on a STOVL aircraft design.
Pacifier and swaddling effective in impeding premature infant's pain score and heart rate.
Efendi, Defi; Rustina, Yeni; Gayatri, Dewi
2018-02-01
To assess the effectiveness of pacifier and swaddling on premature infant's pain score, hearthrate, and oxygen saturation during an invasive procedure. This randomized control trial involv 30 premature infants who were randomly assigned into control (n=15) and intervention (n=15) groups using parallel design. Infants in the intervention group received pacifier and swaddling when they were undergoing invasive procedures. The outcome indicators of the two-day intervention were pain score, hearth rate, and oxygen saturation. The Premature Infant Pain Profile (PIPP) was used in this study to measure infants' pain. The paired t-test results showed that the pain score and heart rate were significantly increased following the procedure in the control group (p=0.003; p=0.013 < 0.05); meanwhile, there was no significant increase in the intervention group (p=0.256; p=0.783 > 0.005). There was no significant different in oxygen saturation in the control group (p=0.270) and in the intervention (p=0.370) group before and after the procedure. Providing pacifier and swaddling can impede the increase of premature infants' pain score and hearth rate during an invasive procedures, therefore it can be implemented as an alternative to pain management in premature infants. Copyright © 2018 Elsevier España, S.L.U. All rights reserved.
Quantitative trait Loci analysis using the false discovery rate.
Benjamini, Yoav; Yekutieli, Daniel
2005-10-01
False discovery rate control has become an essential tool in any study that has a very large multiplicity problem. False discovery rate-controlling procedures have also been found to be very effective in QTL analysis, ensuring reproducible results with few falsely discovered linkages and offering increased power to discover QTL, although their acceptance has been slower than in microarray analysis, for example. The reason is partly because the methodological aspects of applying the false discovery rate to QTL mapping are not well developed. Our aim in this work is to lay a solid foundation for the use of the false discovery rate in QTL mapping. We review the false discovery rate criterion, the appropriate interpretation of the FDR, and alternative formulations of the FDR that appeared in the statistical and genetics literature. We discuss important features of the FDR approach, some stemming from new developments in FDR theory and methodology, which deem it especially useful in linkage analysis. We review false discovery rate-controlling procedures--the BH, the resampling procedure, and the adaptive two-stage procedure-and discuss the validity of these procedures in single- and multiple-trait QTL mapping. Finally we argue that the control of the false discovery rate has an important role in suggesting, indicating the significance of, and confirming QTL and present guidelines for its use.
Sweeney, Mary M.; Shahan, Timothy A.
2016-01-01
Resurgence following removal of alternative reinforcement has been studied in non-human animals, children with developmental disabilities, and typically functioning adults. Adult human laboratory studies have included responses without a controlled history of reinforcement, included only two response options, or involved extensive training. Arbitrary responses allow for control over history of reinforcement. Including an inactive response never associated with reinforcement allows the conclusion that resurgence exceeds extinction-induced variability. Although procedures with extensive training produce reliable resurgence, a brief procedure with the same experimental control would allow more efficient examination of resurgence in adult humans. We tested the acceptability of a brief, single-session, three-alternative forced-choice procedure as a model of resurgence in undergraduates. Selecting a shape was the target response (reinforced in Phase I), selecting another shape was the alternative response (reinforced in Phase II), and selecting a third shape was never reinforced. Despite manipulating number of trials and probability of reinforcement, resurgence of the target response did not consistently exceed increases in the inactive response. Our findings reiterate the importance of an inactive control response and call for reexamination of resurgence studies using only two response options. We discuss potential approaches to generate an acceptable, brief human laboratory resurgence procedure. PMID:26724752
Controls for and constraints on auto-shaping
Bilbrey, John; Winokur, Stephen
1973-01-01
Auto-shaping the pigeon's key-peck response was examined as a respondent conditioning procedure with the use of Rescorla's truly-random control procedure. In the first experiment, pigeons received presentations of brief light on the response key and brief presentations of food where the light and the food were independently presented. All birds failed to key peck after many light and food presentations, but explicit pairing of the light and food rapidly conditioned pecking to the light. Experiment 2 showed that even when an independent light/food presentation schedule was reduced to variable-time 30 sec, additional naive birds would not key peck and only one bird pecked when the schedules were variable-time 15 sec. A third experiment examined an explicit-unpairing control procedure, where the light and food were not only presented on independent schedules but were also separated by a minimum time, and found that auto-shaping did not occur. A fourth experiment investigated a number of control procedures and found them ineffective. A fifth experiment investigated the effects of a physical separation of the locus of the response key and the food dispenser, and a sixth experiment investigated using a tone in place of the light. It was concluded that pecking is generated by auto-shaping procedures only when an intermittently presented keylight is regularly paired with food. PMID:16811710
[Design of an HACCP program for a cocoa processing facility].
López D'Sola, Patrizia; Sandia, María Gabriela; Bou Rached, Lizet; Hernández Serrano, Pilar
2012-12-01
The HACCP plan is a food safety management tool used to control physical, chemical and biological hazards associated to food processing through all the processing chain. The aim of this work is to design a HACCP Plan for a Venezuelan cocoa processing facility.The production of safe food products requires that the HACCP system be built upon a solid foundation of prerequisite programs such as Good Manufacturing Practices (GMP) and Sanitation Standard Operating Procedures (SSOP). The existence and effectiveness of these prerequisite programs were previously assessed.Good Agriculture Practices (GAP) audit to cocoa nibs suppliers were performed. To develop the HACCP plan, the five preliminary tasks and the seven HACCP principles were accomplished according to Codex Alimentarius procedures. Three Critical Control Points (CCP) were identified using a decision tree: winnowing (control of ochratoxin A), roasting (Salmonella control) and metallic particles detection. For each CCP, Critical limits were established, the Monitoring procedures, Corrective actions, Procedures for Verification and Documentation concerning all procedures and records appropriate to these principles and their application was established. To implement and maintain a HACCP plan for this processing plant is suggested. Recently OchratoxinA (OTA) has been related to cocoa beans. Although the shell separation from the nib has been reported as an effective measure to control this chemical hazard, ochratoxin prevalence study in cocoa beans produced in the country is recommended, and validate the winnowing step as well
Selecting Statistical Procedures for Quality Control Planning Based on Risk Management.
Yago, Martín; Alcover, Silvia
2016-07-01
According to the traditional approach to statistical QC planning, the performance of QC procedures is assessed in terms of its probability of rejecting an analytical run that contains critical size errors (PEDC). Recently, the maximum expected increase in the number of unacceptable patient results reported during the presence of an undetected out-of-control error condition [Max E(NUF)], has been proposed as an alternative QC performance measure because it is more related to the current introduction of risk management concepts for QC planning in the clinical laboratory. We used a statistical model to investigate the relationship between PEDC and Max E(NUF) for simple QC procedures widely used in clinical laboratories and to construct charts relating Max E(NUF) with the capability of the analytical process that allow for QC planning based on the risk of harm to a patient due to the report of erroneous results. A QC procedure shows nearly the same Max E(NUF) value when used for controlling analytical processes with the same capability, and there is a close relationship between PEDC and Max E(NUF) for simple QC procedures; therefore, the value of PEDC can be estimated from the value of Max E(NUF) and vice versa. QC procedures selected by their high PEDC value are also characterized by a low value for Max E(NUF). The PEDC value can be used for estimating the probability of patient harm, allowing for the selection of appropriate QC procedures in QC planning based on risk management. © 2016 American Association for Clinical Chemistry.
Radiofrequency Procedures to Relieve Chronic Knee Pain: An Evidence-Based Narrative Review.
Bhatia, Anuj; Peng, Philip; Cohen, Steven P
2016-01-01
Chronic knee pain from osteoarthritis or following arthroplasty is a common problem. A number of publications have reported analgesic success of radiofrequency (RF) procedures on nerves innervating the knee, but interpretation is hampered by lack of clarity regarding indications, clinical protocols, targets, and longevity of benefit from RF procedures. We reviewed the following medical literature databases for publications on RF procedures on the knee joint for chronic pain: MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and Google Scholar up to August 9, 2015. Data on scores for pain, validated scores for measuring physical disability, and adverse effects measured at any timepoint after 1 month following the interventions were collected, analyzed, and reported in this narrative review. Thirteen publications on ablative or pulsed RF treatments of innervation of the knee joint were identified. A high success rate of these procedures in relieving chronic pain of the knee joint was reported at 1 to 12 months after the procedures, but only 2 of the publications were randomized controlled trials. There was evidence for improvement in function and a lack of serious adverse events of RF treatments. Radiofrequency treatments on the knee joint (major or periarticular nerve supply or intra-articular branches) have the potential to reduce pain from osteoarthritis or persistent postarthroplasty pain. Ongoing concerns regarding the quality, procedural aspects, and monitoring of outcomes in publications on this topic remain. Randomized controlled trials of high methodological quality are required to further elaborate role of these interventions in this population.
Fuldeore, M; Chwalisz, K; Marx, S; Wu, N; Boulanger, L; Ma, L; Lamothe, K
2011-01-01
This descriptive study assessed the rate and costs of surgical procedures among newly diagnosed endometriosis patients. Utilizing the Medstat MarketScan database, commercially insured women aged 18-45 with endometriosis newly diagnosed during 2006-2007 were identified. Each endometriosis patient was matched to four women without endometriosis (population controls) based on age and region of residence. Surgical procedures received during the 12 months post-diagnosis were assessed. Costs of surgical procedures were the amount paid by the insurance companies. This study identified 15,891 women with newly diagnosed endometriosis and 63,564 population controls. More than 65% of endometriosis patients received an endometriosis-related surgical procedure within 1 year of the initial diagnosis. The most common procedure was therapeutic laparoscopy (31.6%), followed by abdominal hysterectomy (22.1%) and vaginal hysterectomy (6.8%). Prevalence and type of surgery performed varied by patient age, including a hysterectomy rate of approximately 16% in patients younger than 35 and 37% among patients aged 35-45 years. Average costs ranged from $4,289 (standard deviation [SD]: $3,313) for diagnostic laparoscopy to $11,397 (SD: $8,749) for abdominal hysterectomy. Diagnosis of endometriosis cannot be validated against medical records, and information on the severity of endometriosis-related symptoms is not available in administrative claims data. Over 65% of patients had endometriosis-related surgical procedures, including hysterectomy, within 1 year of being diagnosed with endometriosis. The cost of surgical procedures related to endometriosis places a significant financial burden on the healthcare system.
Patients' perceptions and responses to procedural pain: results from Thunder Project II.
Puntillo, K A; White, C; Morris, A B; Perdue, S T; Stanik-Hutt, J; Thompson, C L; Wild, L R
2001-07-01
Little is known about the painfulness of procedures commonly performed in acute and critical care settings. To describe pain associated with turning, wound drain removal, tracheal suctioning, femoral catheter removal, placement of a central venous catheter, and nonburn wound dressing change and frequency of use of analgesics during procedures. A comparative, descriptive design was used. Numeric rating scales were used to measure pain intensity and procedural distress; word lists, to measure pain quality. Data were obtained from 6201 patients: 176 younger than 18 years and 5957 adults. Mean pain intensity scores for turning and tracheal suctioning were 2.80 and 3.00, respectively (scale, 0-5), for 4- to 7-year-olds and 52.0 and 28.1 (scale, 0-100) for 8- to 12-year-olds. For adolescents, mean pain intensity scores for wound dressing change, turning, tracheal suctioning, and wound drain removal were 5 to 7 (scale, 0-10); mean procedural distress scores were 4.83 to 6.00 (scale, 0-10). In adults, mean pain intensity scores for all procedures were 2.65 to 4.93 (scale, 0-10); mean procedural distress scores were 1.89 to 3.47 (scale, 0-10). The most painful and distressing procedures were turning for adults and wound care for adolescents. Procedural pain was often described as sharp, stinging, stabbing, shooting, and awful. Less than 20% of patients received opiates before procedures. Procedural pain varies considerably and is procedure specific. Because procedures are performed so often, more individualized attention to preparation for and control of procedural pain is warranted.
34 CFR 303.323 - Nondiscriminatory procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Services Identification and Evaluation § 303.323 Nondiscriminatory procedures. Each lead agency shall adopt... qualified personnel. (Approved by the Office of Management and Budget under control number 1820-0550...
10 CFR 26.137 - Quality assurance and quality control.
Code of Federal Regulations, 2013 CFR
2013-01-01
... validation of analytical procedures. Quality assurance procedures must be designed, implemented, and reviewed... resolving any technical, methodological, or administrative errors in the licensee testing facility's testing...
10 CFR 26.137 - Quality assurance and quality control.
Code of Federal Regulations, 2010 CFR
2010-01-01
... validation of analytical procedures. Quality assurance procedures must be designed, implemented, and reviewed... resolving any technical, methodological, or administrative errors in the licensee testing facility's testing...
10 CFR 26.137 - Quality assurance and quality control.
Code of Federal Regulations, 2011 CFR
2011-01-01
... validation of analytical procedures. Quality assurance procedures must be designed, implemented, and reviewed... resolving any technical, methodological, or administrative errors in the licensee testing facility's testing...
10 CFR 26.137 - Quality assurance and quality control.
Code of Federal Regulations, 2012 CFR
2012-01-01
... validation of analytical procedures. Quality assurance procedures must be designed, implemented, and reviewed... resolving any technical, methodological, or administrative errors in the licensee testing facility's testing...
10 CFR 26.137 - Quality assurance and quality control.
Code of Federal Regulations, 2014 CFR
2014-01-01
... validation of analytical procedures. Quality assurance procedures must be designed, implemented, and reviewed... resolving any technical, methodological, or administrative errors in the licensee testing facility's testing...
Role of the Controller in an Integrated Pilot-Controller Study for Parallel Approaches
NASA Technical Reports Server (NTRS)
Verma, Savvy; Kozon, Thomas; Ballinger, Debbi; Lozito, Sandra; Subramanian, Shobana
2011-01-01
Closely spaced parallel runway operations have been found to increase capacity within the National Airspace System but poor visibility conditions reduce the use of these operations [1]. Previous research examined the concepts and procedures related to parallel runways [2][4][5]. However, there has been no investigation of the procedures associated with the strategic and tactical pairing of aircraft for these operations. This study developed and examined the pilot s and controller s procedures and information requirements for creating aircraft pairs for closely spaced parallel runway operations. The goal was to achieve aircraft pairing with a temporal separation of 15s (+/- 10s error) at a coupling point that was 12 nmi from the runway threshold. In this paper, the role of the controller, as examined in an integrated study of controllers and pilots, is presented. The controllers utilized a pairing scheduler and new pairing interfaces to help create and maintain aircraft pairs, in a high-fidelity, human-in-the loop simulation experiment. Results show that the controllers worked as a team to achieve pairing between aircraft and the level of inter-controller coordination increased when the aircraft in the pair belonged to different sectors. Controller feedback did not reveal over reliance on the automation nor complacency with the pairing automation or pairing procedures.
Usta, Murat; Aral, Hale; Mete Çilingirtürk, Ahmet; Kural, Alev; Topaç, Ibrahim; Semerci, Tuna; Hicri Köseoğlu, Mehmet
2016-11-01
Average of normals (AON) is a quality control procedure that is sensitive only to systematic errors that can occur in an analytical process in which patient test results are used. The aim of this study was to develop an alternative model in order to apply the AON quality control procedure to datasets that include qualitative values below limit of detection (LoD). The reported patient test results for tumor markers, such as CA 15-3, CA 125, and CA 19-9, analyzed by two instruments, were retrieved from the information system over a period of 5 months, using the calibrator and control materials with the same lot numbers. The median as a measure of central tendency and the median absolute deviation (MAD) as a measure of dispersion were used for the complementary model of AON quality control procedure. The u bias values, which were determined for the bias component of the measurement uncertainty, were partially linked to the percentages of the daily median values of the test results that fall within the control limits. The results for these tumor markers, in which lower limits of reference intervals are not medically important for clinical diagnosis and management, showed that the AON quality control procedure, using the MAD around the median, can be applied for datasets including qualitative values below LoD.
VERIFICATION OF SIMPLIFIED PROCEDURES FOR SITE- SPECIFIC SO2 AND NOX CONTROL COST ESTIMATES
The report documents results of an evaluation to verify the accuracy of simplified procedures for estimating sulfur dioxide (S02) and nitrogen oxides (NOx) retrofit control costs and performance for 200 502-emitting coal-fired power plants in the 31-state eastern region. nitially...
28 CFR 104.71 - Procedures to prevent and detect fraud.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... 104.71 Section 104.71 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED) SEPTEMBER 11TH VICTIM... prevent and detect fraud. (a) Review of claims. For the purpose of detecting and preventing the payment of...; and (3) Ensure the quality control of claims review procedures. (b) Quality control. The Special...
A Behavioral Weight Control Program for Residence Hall Students.
ERIC Educational Resources Information Center
Domke, Jane A.; And Others
1981-01-01
Compared a weight control treatment specifically tailored to the needs of residence hall students with a standardized behavioral procedure. Although posttreatment results indicated a very slight and nonsignificant advantage for the residence hall condition, this was not true at follow-up. Suggests the residence hall procedure may be overly…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-23
... maintenance intervals, recordkeeping, warranties, test procedures, certification test fuel, and engine useful... Control of Emissions of Air Pollution From Nonroad Diesel Engines and Fuel and EPA's Final Rule for Test... request for an authorization of its emission standards and accompanying test procedures for new nonroad...
34 CFR 686.36 - Fiscal control and fund accounting procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 34 Education 3 2010-07-01 2010-07-01 false Fiscal control and fund accounting procedures. 686.36 Section 686.36 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF POSTSECONDARY EDUCATION, DEPARTMENT OF EDUCATION TEACHER EDUCATION ASSISTANCE FOR COLLEGE AND HIGHER EDUCATION...
Project #OA-FY17-0382, October 6, 2017 - The EPA OIG plans to expand the scope of preliminary research on the EPA’s adherence to policies, procedures and oversight controls pertaining to the Administrator’s travel.
This SOP describes the method for conducting internal field audits and quality control procedures. Internal field audits will be conducted to ensure the collection of high quality data. Internal field audits will be conducted by Field Auditors (the Field QA Officer and the Field...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-08
... adequate accounting system, internal accounting controls, and procedures for safeguarding customer and firm... an adequate accounting system, internal accounting controls, and procedures for safeguarding customer... ability to provide to the Exchange in an acceptable form a complete set of equity system reports...
Code of Federal Regulations, 2013 CFR
2013-07-01
... and Group 1/Group 2 determinations (determining which wastewater streams require control). (a... methods and procedures for determining applicability and Group 1/Group 2 determinations (determining which wastewater streams require control). 63.144 Section 63.144 Protection of Environment ENVIRONMENTAL PROTECTION...
Code of Federal Regulations, 2010 CFR
2010-07-01
... and Group 1/Group 2 determinations (determining which wastewater streams require control). (a... methods and procedures for determining applicability and Group 1/Group 2 determinations (determining which wastewater streams require control). 63.144 Section 63.144 Protection of Environment ENVIRONMENTAL PROTECTION...
Code of Federal Regulations, 2014 CFR
2014-07-01
... and Group 1/Group 2 determinations (determining which wastewater streams require control). (a... methods and procedures for determining applicability and Group 1/Group 2 determinations (determining which wastewater streams require control). 63.144 Section 63.144 Protection of Environment ENVIRONMENTAL PROTECTION...
Code of Federal Regulations, 2011 CFR
2011-07-01
... and Group 1/Group 2 determinations (determining which wastewater streams require control). (a... methods and procedures for determining applicability and Group 1/Group 2 determinations (determining which wastewater streams require control). 63.144 Section 63.144 Protection of Environment ENVIRONMENTAL PROTECTION...
Code of Federal Regulations, 2012 CFR
2012-07-01
... and Group 1/Group 2 determinations (determining which wastewater streams require control). (a... methods and procedures for determining applicability and Group 1/Group 2 determinations (determining which wastewater streams require control). 63.144 Section 63.144 Protection of Environment ENVIRONMENTAL PROTECTION...
34 CFR 691.81 - Fiscal control and fund accounting procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 34 Education 4 2012-07-01 2012-07-01 false Fiscal control and fund accounting procedures. 691.81 Section 691.81 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF POSTSECONDARY EDUCATION, DEPARTMENT OF EDUCATION (CONTINUED) ACADEMIC COMPETITIVENESS GRANT (ACG) AND NATIONAL...
34 CFR 691.81 - Fiscal control and fund accounting procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 34 Education 4 2011-07-01 2011-07-01 false Fiscal control and fund accounting procedures. 691.81 Section 691.81 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF POSTSECONDARY EDUCATION, DEPARTMENT OF EDUCATION (CONTINUED) ACADEMIC COMPETITIVENESS GRANT (ACG) AND NATIONAL...
34 CFR 691.81 - Fiscal control and fund accounting procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 34 Education 4 2014-07-01 2014-07-01 false Fiscal control and fund accounting procedures. 691.81 Section 691.81 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF POSTSECONDARY EDUCATION, DEPARTMENT OF EDUCATION (CONTINUED) ACADEMIC COMPETITIVENESS GRANT (ACG) AND NATIONAL...
34 CFR 691.81 - Fiscal control and fund accounting procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 34 Education 4 2013-07-01 2013-07-01 false Fiscal control and fund accounting procedures. 691.81 Section 691.81 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF POSTSECONDARY EDUCATION, DEPARTMENT OF EDUCATION (CONTINUED) ACADEMIC COMPETITIVENESS GRANT (ACG) AND NATIONAL...
34 CFR 691.81 - Fiscal control and fund accounting procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 34 Education 3 2010-07-01 2010-07-01 false Fiscal control and fund accounting procedures. 691.81 Section 691.81 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF POSTSECONDARY EDUCATION, DEPARTMENT OF EDUCATION ACADEMIC COMPETITIVENESS GRANT (ACG) AND NATIONAL SCIENCE AND...
Miles, Luke F; Frelich, Matthew J; Gould, Jon C; Dua, Kulwinder S; Jensen, Eric S; Kastenmeier, Andrew S
2015-10-01
We sought to evaluate the feasibility, safety, and difficulty of performing the per-oral endoscopic myotomy (POEM) procedure in the setting of a prior Heller myotomy using a survival porcine model. Four pigs underwent laparoscopic Heller myotomy with Dor partial anterior fundoplication followed by the POEM performed 4 weeks later. Two additional pigs served as controls, undergoing only the POEM. All procedures were completed without complications. The revisional POEM was not significantly more difficult than POEM controls based on procedure time, POEM procedure components, or procedure difficulty scores. Revisional POEM had a longer mean operative time when compared with Heller myotomy (126.0 vs. 83.8 min; P<0.01) but had a lower total difficulty score (28.6 vs. 52.1; P≪0.01). A POEM after previous Heller myotomy is safe and feasible in the porcine model and has potential as an option for patients suffering from recurrent or persistent symptoms after failed surgical myotomy.
Toward an explicit analysis of generalization: A stimulus control interpretation
Kirby, Kimberly C.; Bickel, Warren K.
1988-01-01
Producing generality of treatment effects to new settings has been a critical concern for applied behavior analysts, but a systematic and reliable means of producing generality has yet to be provided. We argue that the principles of stimulus control and reinforcement underlie the production of most generalized effects; therefore, we suggest interpreting generalization programming in terms of stimulus control. The generalization programming procedures identified by Stokes and Baer (1977) are discussed in terms of both the stimulus control tactics explicitly identified and those that may be operating but are not explicitly identified. Our interpretation clarifies the critical components of Stokes and Baer's procedures and places greater emphasis on planning for generalization as a part of training procedures. PMID:22478006
48 CFR 1503.500-71 - Procedures.
Code of Federal Regulations, 2010 CFR
2010-10-01
... for: (1) A written code of business ethics and conduct and an ethics training program for all employees; (2) Periodic reviews of company business practices, procedures, policies and internal controls...
Energy Navigation: Simulation Evaluation and Benefit Analysis
NASA Technical Reports Server (NTRS)
Williams, David H.; Oseguera-Lohr, Rosa M.; Lewis, Elliot T.
2011-01-01
This paper presents results from two simulation studies investigating the use of advanced flight-deck-based energy navigation (ENAV) and conventional transport-category vertical navigation (VNAV) for conducting a descent through a busy terminal area, using Continuous Descent Arrival (CDA) procedures. This research was part of the Low Noise Flight Procedures (LNFP) element within the Quiet Aircraft Technology (QAT) Project, and the subsequent Airspace Super Density Operations (ASDO) research focus area of the Airspace Project. A piloted simulation study addressed development of flight guidance, and supporting pilot and Air Traffic Control (ATC) procedures for high density terminal operations. The procedures and charts were designed to be easy to understand, and to make it easy for the crew to make changes via the Flight Management Computer Control-Display Unit (FMC-CDU) to accommodate changes from ATC.
NASA Technical Reports Server (NTRS)
Safford, Robert R.; Jackson, Andrew E.; Swart, William W.; Barth, Timothy S.
1994-01-01
Successful ground processing at KSC requires that flight hardware and ground support equipment conform to specifications at tens of thousands of checkpoints. Knowledge of conformance is an essential requirement for launch. That knowledge of conformance at every requisite point does not, however, enable identification of past problems with equipment, or potential problem areas. This paper describes how the introduction of Statistical Process Control and Process Capability Analysis identification procedures into existing shuttle processing procedures can enable identification of potential problem areas and candidates for improvements to increase processing performance measures. Results of a case study describing application of the analysis procedures to Thermal Protection System processing are used to illustrate the benefits of the approaches described in the paper.
The Impact of Incentives on Exercise Behavior: A Systematic Review of Randomized Controlled Trials
Strohacker, Kelley; Galarraga, Omar; Williams, David M.
2015-01-01
Background The effectiveness of reinforcing exercise behavior with material incentives is unclear. Purpose Conduct a systematic review of existing research on material incentives for exercise, organized by incentive strategy. Methods Ten studies conducted between January 1965 and June 2013 assessed the impact of incentivizing exercise compared to a non-incentivized control. Results There was significant heterogeneity between studies regarding reinforcement procedures and outcomes. Incentives tended to improve behavior during the intervention while findings were mixed regarding sustained behavior after incentives were removed. Conclusions The most effective incentive procedure is unclear given the limitations of existing research. The effectiveness of various incentive procedures in promoting initial behavior change and habit formation, as well as the use of sustainable incentive procedures should be explored in future research. PMID:24307474
Dawe, Philip; Kirkpatrick, Andrew; Talbot, Max; Beckett, Andrew; Garraway, Naisan; Wong, Heather; Hameed, Syed Morad
2018-05-01
Damage-control and emergency surgical procedures in trauma have the potential to save lives. They may occasionally not be performed due to clinician inexperience or lack of comfort and knowledge. Canadian Armed Forces (CAF) non-surgeon Medical Officers (MOs) participated in a live tissue training exercise. They received tele-mentoring assistance using a secure video-conferencing application on a smartphone/tablet platform. Feasibility of tele-mentored surgery was studied by measuring their effectiveness at completing a set series of tasks in this pilot study. Additionally, their comfort and willingness to perform studied procedures was gauged using pre- and post-study surveys. With no pre-procedural teaching, participants were able to complete surgical airway, chest tube insertion and resuscitative thoracotomy with 100% effectiveness with no noted complications. Comfort level and willingness to perform these procedures were improved with tele-mentoring. Participants felt that tele-mentored surgery would benefit their performance of resuscitative thoracotomy most. The use of tele-mentored surgery to assist non-surgeon clinicians in the performance of damage-control and emergency surgical procedures is feasible. More study is required to validate its effectiveness. Copyright © 2018 Elsevier Inc. All rights reserved.
Zhuang, Yaling; Zhu, Xiufang; Huang, Li-Li
2010-02-01
First-trimester surgical abortion is a common procedure. Pain control during this procedure is still an unsolved problem. In this randomized, double-blind placebo-controlled study, women presenting for first-trimester surgical abortion received intramuscular phloroglucinol (4 mL) or placebo (normal saline, 4 mL). Visual analog scales (VAS) for pain immediately and 30 min after the procedure and side effects of the drug were recorded. There was no significant difference between groups in the pain level immediately and 30 min after the procedure; 70.7% of the phloroglucinol group (n=58 cases) and 56.9% of the placebo group (n=58 cases ) reported mild pain; 27.6% and 34.5%, respectively, reported moderate pain; and 1.7% and 8.6%, respectively, reported severe pain. Thirty minutes after the procedure, the median pain score was reduced to 1.3 in both groups. Postoperative side effects were reported, but there was no significant difference between groups for nausea or vomiting and blood pressure. The use of this dose of phloroglucinol, during first-trimester abortion by suction evacuation under local anesthesia with lidocaine, did not relieve pain, but caused no side effects.