Sample records for control sample results

  1. Interim results of quality-control sampling of surface water for the Upper Colorado River National Water-Quality Assessment Study Unit, water years 1995-96

    USGS Publications Warehouse

    Spahr, N.E.; Boulger, R.W.

    1997-01-01

    Quality-control samples provide part of the information needed to estimate the bias and variability that result from sample collection, processing, and analysis. Quality-control samples of surface water collected for the Upper Colorado River National Water-Quality Assessment study unit for water years 1995?96 are presented and analyzed in this report. The types of quality-control samples collected include pre-processing split replicates, concurrent replicates, sequential replicates, post-processing split replicates, and field blanks. Analysis of the pre-processing split replicates, concurrent replicates, sequential replicates, and post-processing split replicates is based on differences between analytical results of the environmental samples and analytical results of the quality-control samples. Results of these comparisons indicate that variability introduced by sample collection, processing, and handling is low and will not affect interpretation of the environmental data. The differences for most water-quality constituents is on the order of plus or minus 1 or 2 lowest rounding units. A lowest rounding unit is equivalent to the magnitude of the least significant figure reported for analytical results. The use of lowest rounding units avoids some of the difficulty in comparing differences between pairs of samples when concentrations span orders of magnitude and provides a measure of the practical significance of the effect of variability. Analysis of field-blank quality-control samples indicates that with the exception of chloride and silica, no systematic contamination of samples is apparent. Chloride contamination probably was the result of incomplete rinsing of the dilute cleaning solution from the outlet ports of the decaport sample splitter. Silica contamination seems to have been introduced by the blank water. Sampling and processing procedures for water year 1997 have been modified as a result of these analyses.

  2. Quality-Assurance Data for Routine Water Analyses by the U.S. Geological Survey Laboratory in Troy, New York--July 1999 through June 2001

    USGS Publications Warehouse

    Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.

    2006-01-01

    The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance and quality-control data were stored in the laboratory's LabMaster data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality-control samples analyzed from July 1999 through June 2001. Results for the quality-control samples for 18 analytical procedures were evaluated for bias and precision. Control charts indicate that data for eight of the analytical procedures were occasionally biased for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, total monomeric aluminum, total aluminum, calcium, chloride and nitrate (ion chromatography and colormetric method) and sulfate. The total aluminum and dissolved organic carbon procedures were biased throughout the analysis period for the high-concentration sample, but were within control limits. The calcium and specific conductance procedures were biased throughout the analysis period for the low-concentration sample, but were within control limits. The magnesium procedure was biased for the high-concentration and low concentration samples, but was within control limits. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 14 of 15 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. The data-quality objective was not met for dissolved organic carbon. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 17 of the 18 analytes. At least 90 percent of the samples met data-quality objectives for all analytes except ammonium (81 percent of samples met objectives), chloride (75 percent of samples met objectives), and sodium (86 percent of samples met objectives). Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated good data quality over the time period, with most ratings for each sample in the good to excellent range. The P-sample (low-ionic-strength constituents) analysis had one satisfactory rating for the specific conductance procedure in one study. The T-sample (trace constituents) analysis had one satisfactory rating for the aluminum procedure in one study and one unsatisfactory rating for the sodium procedure in another. The remainder of the samples had good or excellent ratings for each study. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 89 percent of the samples met data-quality objectives for 10 of the 14 analytes; the exceptions were ammonium, total aluminum, dissolved organic carbon, and sodium. Results indicate a positive bias for the ammonium procedure in all studies. Data-quality objectives were not met in 50 percent of samples analyzed for total aluminum, 38 percent of samples analyzed for dissolved organic carbon, and 27 percent of samples analyzed for sodium. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 91 percent of the samples analyzed for calcium, chloride, fluoride, magnesium, pH, potassium, and sulfate. Data-quality objectives were met by 75 percent of the samples analyzed for sodium and 58 percent of the samples analyzed for specific conductance.

  3. First evaluation of automated specimen inoculation for wound swab samples by use of the Previ Isola system compared to manual inoculation in a routine laboratory: finding a cost-effective and accurate approach.

    PubMed

    Mischnik, Alexander; Mieth, Markus; Busch, Cornelius J; Hofer, Stefan; Zimmermann, Stefan

    2012-08-01

    Automation of plate streaking is ongoing in clinical microbiological laboratories, but evaluation for routine use is mostly open. In the present study, the recovery of microorganisms from the Previ Isola system plated polyurethane (PU) swab samples is compared to manually plated control viscose swab samples from wounds according to the CLSI procedure M40-A (quality control of microbiological transport systems). One hundred twelve paired samples (224 swabs) were analyzed. In 80/112 samples (71%), concordant culture results were obtained with the two methods. In 32/112 samples (29%), CFU recovery of microorganisms from the two methods was discordant. In 24 (75%) of the 32 paired samples with a discordant result, Previ Isola plated PU swabs were superior. In 8 (25%) of the 32 paired samples with a discordant result, control viscose swabs were superior. The quality of colony growth on culture media for further investigations was superior with Previ Isola inoculated plates compared to manual plating techniques. Gram stain results were concordant between the two methods in 62/112 samples (55%). In 50/112 samples (45%), the results of Gram staining were discordant between the two methods. In 34 (68%) of the 50 paired samples with discordant results, Gram staining of PU swabs was superior to that of control viscose swabs. In 16 (32%) of the 50 paired samples, Gram staining of control viscose swabs was superior to that of PU swabs. We report the first clinical evaluation of Previ Isola automated specimen inoculation for wound swab samples. This study suggests that use of an automated specimen inoculation system has good results with regard to CFU recovery, quality of Gram staining, and accuracy of diagnosis.

  4. First Evaluation of Automated Specimen Inoculation for Wound Swab Samples by Use of the Previ Isola System Compared to Manual Inoculation in a Routine Laboratory: Finding a Cost-Effective and Accurate Approach

    PubMed Central

    Mieth, Markus; Busch, Cornelius J.; Hofer, Stefan; Zimmermann, Stefan

    2012-01-01

    Automation of plate streaking is ongoing in clinical microbiological laboratories, but evaluation for routine use is mostly open. In the present study, the recovery of microorganisms from the Previ Isola system plated polyurethane (PU) swab samples is compared to manually plated control viscose swab samples from wounds according to the CLSI procedure M40-A (quality control of microbiological transport systems). One hundred twelve paired samples (224 swabs) were analyzed. In 80/112 samples (71%), concordant culture results were obtained with the two methods. In 32/112 samples (29%), CFU recovery of microorganisms from the two methods was discordant. In 24 (75%) of the 32 paired samples with a discordant result, Previ Isola plated PU swabs were superior. In 8 (25%) of the 32 paired samples with a discordant result, control viscose swabs were superior. The quality of colony growth on culture media for further investigations was superior with Previ Isola inoculated plates compared to manual plating techniques. Gram stain results were concordant between the two methods in 62/112 samples (55%). In 50/112 samples (45%), the results of Gram staining were discordant between the two methods. In 34 (68%) of the 50 paired samples with discordant results, Gram staining of PU swabs was superior to that of control viscose swabs. In 16 (32%) of the 50 paired samples, Gram staining of control viscose swabs was superior to that of PU swabs. We report the first clinical evaluation of Previ Isola automated specimen inoculation for wound swab samples. This study suggests that use of an automated specimen inoculation system has good results with regard to CFU recovery, quality of Gram staining, and accuracy of diagnosis. PMID:22692745

  5. Common Control by Compound Samples in Conditional Discriminations

    ERIC Educational Resources Information Center

    Perez-Gonzalez, Luis Antonio; Alonso-Alvarez, Benigno

    2008-01-01

    We tested whether teaching control by single stimulus samples in conditional discriminations would result in common control of two-stimuli compound samples, and vice versa. In Experiment 1, 5 participants were first taught four single-sample conditional discriminations. The first conditional discrimination was as follows: given sample stimulus P1,…

  6. Synchronization of Hierarchical Time-Varying Neural Networks Based on Asynchronous and Intermittent Sampled-Data Control.

    PubMed

    Xiong, Wenjun; Patel, Ragini; Cao, Jinde; Zheng, Wei Xing

    In this brief, our purpose is to apply asynchronous and intermittent sampled-data control methods to achieve the synchronization of hierarchical time-varying neural networks. The asynchronous and intermittent sampled-data controllers are proposed for two reasons: 1) the controllers may not transmit the control information simultaneously and 2) the controllers cannot always exist at any time . The synchronization is then discussed for a kind of hierarchical time-varying neural networks based on the asynchronous and intermittent sampled-data controllers. Finally, the simulation results are given to illustrate the usefulness of the developed criteria.In this brief, our purpose is to apply asynchronous and intermittent sampled-data control methods to achieve the synchronization of hierarchical time-varying neural networks. The asynchronous and intermittent sampled-data controllers are proposed for two reasons: 1) the controllers may not transmit the control information simultaneously and 2) the controllers cannot always exist at any time . The synchronization is then discussed for a kind of hierarchical time-varying neural networks based on the asynchronous and intermittent sampled-data controllers. Finally, the simulation results are given to illustrate the usefulness of the developed criteria.

  7. NHEXAS PHASE I MARYLAND STUDY--QA ANALYTICAL RESULTS FOR PESTICIDES IN SPIKE SAMPLES

    EPA Science Inventory

    The Pesticides in Spikes data set contains the analytical results of measurements of up to 17 pesticides in 12 control samples (spikes) from 11 households. Measurements were made in samples of blood serum. Controls were used to assess recovery of target analytes from a sample m...

  8. Quality-Assurance Data for Routine Water Analyses by the U.S. Geological Survey Laboratory in Troy, New York-July 1997 through June 1999

    USGS Publications Warehouse

    Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.

    2006-01-01

    The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance/quality-control data for the time period addressed in this report were stored in the laboratory's SAS data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality- control samples analyzed from July 1997 through June 1999. Results for the quality-control samples for 18 analytical procedures were evaluated for bias and precision. Control charts indicate that data for eight of the analytical procedures were occasionally biased for either high-concentration and (or) low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, total monomeric aluminum, total aluminum, ammonium, calcium, chloride, specific conductance, and sulfate. The data from the potassium and sodium analytical procedures are insufficient for evaluation. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 11 of 13 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. Blank analysis results for chloride showed that 22 percent of blanks did not meet data-quality objectives and results for dissolved organic carbon showed that 31 percent of the blanks did not meet data-quality objectives. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 14 of the 18 analytes. At least 90 percent of the samples met data-quality objectives for all analytes except total aluminum (70 percent of samples met objectives) and potassium (83 percent of samples met objectives). Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated good data quality for most constituents over the time period. The P-sample (low-ionic-strength constituents) analysis had good ratings in two of these studies and a satisfactory rating in the third. The results of the T-sample (trace constituents) analysis indicated high data quality with good ratings in all three studies. The N-sample (nutrient constituents) studies had one each of excellent, good, and satisfactory ratings. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 80 percent of the samples met data-quality objectives for 9 of the 13 analytes; the exceptions were dissolved organic carbon, ammonium, chloride, and specific conductance. Data-quality objectives were not met for dissolved organic carbon in two NWRI studies, but all of the samples were within control limits for the last study. Data-quality objectives were not met in 41 percent of samples analyzed for ammonium, 25 percent of samples analyzed for chloride, and 30 percent of samples analyzed for specific conductance. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 84 percent of the samples analyzed for calcium, chloride, magnesium, pH, and potassium. Data-quality objectives were met by 73 percent of those analyzed for sulfate. The data-quality objective was not met for sodium. The data are insufficient for evaluation of the specific conductance results.

  9. NHEXAS PHASE I MARYLAND STUDY--QA ANALYTICAL RESULTS FOR PESTICIDE METABOLITES IN SPIKE SAMPLES

    EPA Science Inventory

    The Pesticides in Spikes data set contains the analytical results of measurements of up to 17 pesticides in 12 control samples (spikes) from 11 households. Measurements were made in samples of blood serum. Controls were used to assess recovery of target analytes from a sample m...

  10. Quality-assurance data for routine water quality analyses by the U. S. Geological Survey laboratory in Troy, New York; July 1993 through June 1995

    USGS Publications Warehouse

    Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.

    2001-01-01

    A laboratory for analysis of low-ionic strength water has been developed at the U.S. Geological Survey (USGS) office in Troy, N.Y., to analyze samples collected by USGS projects in the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures developed to ensure proper sample collection, processing, and analysis. The quality-assurance/quality-control data are stored in the laboratory's SAS data-management system, which provides efficient review, compilation, and plotting of quality-assurance/quality-control data. This report presents and discusses samples analyzed from July 1993 through June 1995. Quality-control results for 18 analytical procedures were evaluated for bias and precision. Control charts show that data from seven of the analytical procedures were biased throughout the analysis period for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, dissolved inorganic carbon, dissolved organic carbon (soil expulsions), chloride, magnesium, nitrate (colorimetric method), and pH. Three of the analytical procedures were occasionally biased but were within control limits; they were: calcium (high for high-concentration samples for May 1995), dissolved organic carbon (high for highconcentration samples from January through September 1994), and fluoride (high in samples for April and June 1994). No quality-control sample has been developed for the organic monomeric aluminum procedure. Results from the filter-blank and analytical-blank analyses indicate that all analytical procedures in which blanks were run were within control limits, although values for a few blanks were outside the control limits. Blanks were not analyzed for acid-neutralizing capacity, dissolved inorganic carbon, fluoride, nitrate (colorimetric method), or pH. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in 14 of the 18 procedures. Data-quality objectives were met by more than 90 percent of the samples analyzed in all procedures except total monomeric aluminum (85 percent of samples met objectives), total aluminum (70 percent of samples met objectives), and dissolved organic carbon (85 percent of samples met objectives). Triplicate samples were not analyzed for ammonium, fluoride, dissolved inorganic carbon, or nitrate (colorimetric method). Results of the USGS interlaboratory Standard Reference Sample Program indicated high data quality with a median result of 3.6 of a possible 4.0. Environment Canada's LRTAP interlaboratory study results indicated that more than 85 percent of the samples met data-quality objectives in 6 of the 12 analyses; exceptions were calcium, dissolved organic carbon, chloride, pH, potassium, and sodium. Data-quality objectives were not met for calcium samples in one LRTAP study, but 94 percent of samples analyzed were within control limits for the remaining studies. Data-quality objectives were not met by 35 percent of samples analyzed for dissolved organic carbon, but 94 percent of sample values were within 20 percent of the most probable value. Data-quality objectives were not met for 30 percent of samples analyzed for chloride, but 90 percent of sample values were within 20 percent of the most probable value. Measurements of samples with a pH above 6.0 were biased high in 54 percent of the samples, although 85 percent of the samples met data-quality objectives for pH measurements below 6.0. Data-quality objectives for potassium and sodium were not met in one study (only 33 percent of the samples analyzed met the objectives), although 85 percent of the sample values were within control limits for the other studies. Measured sodium values were above the upper control limit in all studies. Results from blind reference-sample analyses indicated that data

  11. Analysis of Tank 38H (HTF-38-16-26, 27) and Tank 43H (HTF-43-16-28, 29) Samples for Support of the Enrichment Control and Corrosion Control Programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hay, M. S.

    Savannah River National Laboratory analyzed samples from Tank 38H and Tank 43H to support Enrichment Control Program and Corrosion Control Program. The total uranium in the Tank 38H samples ranged from 20.5 to 34.0 mg/L while the Tank 43H samples ranged from 47.6 to 50.6 mg/L. The U-235 percentage ranged from 0.62% to 0.64% over the four samples. The total uranium and percent U-235 results appear consistent with previous Tank 38H and Tank 43H uranium measurements. The Tank 38H plutonium results show a large difference between the surface and sub-surface sample concentrations and a somewhat higher concentration than previous sub-surfacemore » samples. The two Tank 43H samples show similar plutonium concentrations and are within the range of values measured on previous samples. The plutonium results may be biased high due to the presence of plutonium contamination in the blank samples from the cell sample preparations. The four samples analyzed show silicon concentrations ranging from 47.9 to 105 mg/L.« less

  12. Quality-Assurance Data for Routine Water Analyses by the U.S. Geological Survey Laboratory in Troy, New York - July 2001 Through June 2003

    USGS Publications Warehouse

    Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.

    2009-01-01

    The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance and quality-control data were stored in the laboratory's Lab Master data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality control samples analyzed from July 2001 through June 2003. Results for the quality-control samples for 19 analytical procedures were evaluated for bias and precision. Control charts indicate that data for six of the analytical procedures were occasionally biased for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, chloride, magnesium, nitrate (ion chromatography), potassium, and sodium. The calcium procedure was biased throughout the analysis period for the high-concentration sample, but was within control limits. The total monomeric aluminum and fluoride procedures were biased throughout the analysis period for the low-concentration sample, but were within control limits. The total aluminum, pH, specific conductance, and sulfate procedures were biased for the high-concentration and low-concentration samples, but were within control limits. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 16 of 18 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. The data-quality objective was not met for the dissolved organic carbon or specific conductance procedures. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 18 of the 21 analytes. At least 90 percent of the samples met data-quality objectives for all procedures except total monomeric aluminum (83 percent of samples met objectives), total aluminum (76 percent of samples met objectives), ammonium (73 percent of samples met objectives), dissolved organic carbon (86 percent of samples met objectives), and nitrate (81 percent of samples met objectives). The data-quality objective was not met for the nitrite procedure. Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated satisfactory or above data quality over the time period, with most performance ratings for each sample in the good-to-excellent range. The N-sample (nutrient constituents) analysis had one unsatisfactory rating for the ammonium procedure in one study. The T-sample (trace constituents) analysis had one unsatisfactory rating for the magnesium procedure and one marginal rating for the potassium procedure in one study and one unsatisfactory rating for the sodium procedure in another. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 90 percent of the samples met data-quality objectives for 10 of the 14 analytes; the exceptions were acid-neutralizing capacity, ammonium, dissolved organic carbon, and sodium. Data-quality objectives were not met in 37 percent of samples analyzed for acid-neutralizing capacity, 28 percent of samples analyzed for dissolved organic carbon, and 30 percent of samples analyzed for sodium. Results indicate a positive bias for the ammonium procedure in one study and a negative bias in another. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 90 percent of the samples analyzed for calcium, chloride, magnesium, pH, potassium, and sodium. Data-quality objectives were met by 78 percent of

  13. Quality-Assurance Data for Routine Water Analyses by the U.S. Geological Survey Laboratory in Troy, New York - July 2005 through June 2007

    USGS Publications Warehouse

    Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.

    2009-01-01

    The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance and quality-control data were stored in the laboratory's Lab Master data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality control samples analyzed from July 2005 through June 2007. Results for the quality-control samples for 19 analytical procedures were evaluated for bias and precision. Control charts indicate that data for eight of the analytical procedures were occasionally biased for either high-concentration or low-concentration samples but were within control limits; these procedures were: total aluminum, calcium, magnesium, nitrate (colorimetric method), potassium, silicon, sodium, and sulfate. Eight of the analytical procedures were biased throughout the analysis period for the high-concentration sample, but were within control limits; these procedures were: total aluminum, calcium, dissolved organic carbon, chloride, nitrate (ion chromatograph), potassium, silicon, and sulfate. The magnesium and pH procedures were biased throughout the analysis period for the low-concentration sample, but were within control limits. The acid-neutralizing capacity, total monomeric aluminum, nitrite, and specific conductance procedures were biased for the high-concentration and low-concentration samples, but were within control limits. Results from the filter-blank and analytical-blank analyses indicated that the procedures for 16 of 17 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. The data-quality objective was not met for dissolved organic carbon. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 18 of the 21 analytes. At least 93 percent of the samples met data-quality objectives for all analytes except acid-neutralizing capacity (85 percent of samples met objectives), total monomeric aluminum (83 percent of samples met objectives), total aluminum (85 percent of samples met objectives), and chloride (85 percent of samples met objectives). The ammonium and total dissolved nitrogen did not meet the data-quality objectives. Results of the USGS interlaboratory Standard Reference Sample (SRS) Project met the Troy Laboratory data-quality objectives for 87 percent of the samples analyzed. The P-sample (low-ionic-strength constituents) analysis had two outliers each in two studies. The T-sample (trace constituents) analysis and the N-sample (nutrient constituents) analysis had one outlier each in two studies. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 85 percent of the samples met data-quality objectives for 11 of the 14 analytes; the exceptions were acid-neutralizing capacity, total aluminum and ammonium. Data-quality objectives were not met in 41 percent of samples analyzed for acid-neutralizing capacity, 50 percent of samples analyzed for total aluminum, and 44 percent of samples analyzed for ammonium. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 86 percent of the samples analyzed for calcium, magnesium, pH, potassium, and sodium. Data-quality objectives were met by 76 percent of the samples analyzed for chloride, 80 percent of the samples analyzed for specific conductance, and 77 percent of the samples analyzed for sulfate.

  14. Quality-assurance data for routine water analyses by the U.S. Geological Survey laboratory in Troy, New York - July 2003 through June 2005

    USGS Publications Warehouse

    Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.

    2009-01-01

    The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance and quality-control data were stored in the laboratory's Lab Master data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality control samples analyzed from July 2003 through June 2005. Results for the quality-control samples for 20 analytical procedures were evaluated for bias and precision. Control charts indicate that data for five of the analytical procedures were occasionally biased for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, total monomeric aluminum, pH, silicon, and sodium. Seven of the analytical procedures were biased throughout the analysis period for the high-concentration sample, but were within control limits; these procedures were: dissolved organic carbon, chloride, nitrate (ion chromatograph), nitrite, silicon, sodium, and sulfate. The calcium and magnesium procedures were biased throughout the analysis period for the low-concentration sample, but were within control limits. The total aluminum and specific conductance procedures were biased for the high-concentration and low-concentration samples, but were within control limits. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 17 of 18 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. The data-quality objective was not met for dissolved organic carbon. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 18 of the 22 analytes. At least 85 percent of the samples met data-quality objectives for all analytes except total monomeric aluminum (82 percent of samples met objectives), total aluminum (77 percent of samples met objectives), chloride (80 percent of samples met objectives), fluoride (76 percent of samples met objectives), and nitrate (ion chromatograph) (79 percent of samples met objectives). The ammonium and total dissolved nitrogen did not meet the data-quality objectives. Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated good data quality over the time period, with ratings for each sample in the satisfactory, good, and excellent ranges or less than 10 percent error. The P-sample (low-ionic-strength constituents) analysis had one marginal and two unsatisfactory ratings for the chloride procedure. The T-sample (trace constituents)analysis had two unsatisfactory ratings and one high range percent error for the aluminum procedure. The N-sample (nutrient constituents) analysis had one marginal rating for the nitrate procedure. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 84 percent of the samples met data-quality objectives for 11 of the 14 analytes; the exceptions were ammonium, total aluminum, and acid-neutralizing capacity. The ammonium procedure did not meet data quality objectives in all studies. Data-quality objectives were not met in 23 percent of samples analyzed for total aluminum and 45 percent of samples analyzed acid-neutralizing capacity. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 86 percent of the samples analyzed for calcium, chloride, fluoride, magnesium, pH, potassium, sodium, and sulfate. Data-quality objectives were not met by samples analyzed for fluoride. 

  15. Internal quality assurance in a clinical virology laboratory. II. Internal quality control.

    PubMed Central

    Gray, J J; Wreghitt, T G; McKee, T A; McIntyre, P; Roth, C E; Smith, D J; Sutehall, G; Higgins, G; Geraghty, R; Whetstone, R

    1995-01-01

    AIMS--In April 1991 additional quality control procedures were introduced into the virology section of the Clinical Microbiology and Public Health Laboratory, Cambridge. Internal quality control (IQC) samples were gradually included in the serological assays performed in the laboratory and supplemented kit controls and standard sera. METHODS--From April 1991 to December 1993, 2421 IQC procedures were carried out with reference sera. RESULTS--The IQC samples were evaluated according to the Westgard rules. Violations were recorded in 60 of 1808 (3.3%) controls and were highest in the IQC samples of complement fixation tests (25/312 (8%) of controls submitted for complement fixation tests). CONCLUSIONS--The inclusion of IQC samples in the serological assays performed in the laboratory has highlighted batch to batch variation in commercial assays. The setting of acceptable limits for the IQC samples has increased confidence in the validity of assay results. PMID:7730475

  16. NHEXAS PHASE I REGION 5 STUDY--QA ANALYTICAL RESULTS FOR METALS IN SPIKES

    EPA Science Inventory

    This data set includes analytical results for measurements of metals in 49 field control samples (spikes). Measurements were made for up to 11 metals in samples of water, blood, and urine. Field controls were used to assess recovery of target analytes from a sample media during s...

  17. NHEXAS PHASE I MARYLAND STUDY--QA ANALYTICAL RESULTS FOR METALS IN SPIKE SAMPLES

    EPA Science Inventory

    The Metals in Spikes data set contains the analytical results of measurements of up to 4 metals in 71 control samples (spikes) from 47 households. Measurements were made in samples of indoor and outdoor air, blood, and urine. Controls were used to assess recovery of target anal...

  18. Manufacturing and shear response characterization of carbon nanofiber modified CFRP using the out-of-autoclave-vacuum-bag-only cure process.

    PubMed

    McDonald, Erin E; Wallace, Landon F; Hickman, Gregory J S; Hsiao, Kuang-Ting

    2014-01-01

    The interlaminar shear response is studied for carbon nanofiber (CNF) modified out-of-autoclave-vacuum-bag-only (OOA-VBO) carbon fiber reinforced plastic (CFRP). Commercial OOA-VBO prepregs were coated with a CNF modified epoxy solution and a control epoxy solution without CNF to make CNF modified samples and control samples, respectively. Tensile testing was used to study the in-plane shear performance of [± 45°]4s composite laminates. Significant difference in failure modes between the control and CNF modified CFRPs was identified. The control samples experienced half-plane interlaminar delamination, whereas the CNF modified samples experienced a localized failure in the intralaminar region. Digital image correlation (DIC) surface strain results of the control sample showed no further surface strain increase along the delaminated section when the sample was further elongated prior to sample failure. On the other hand, the DIC results of the CNF modified sample showed that the surface strain increased relatively and uniformly across the CFRP as the sample was further elongated until sample failure. The failure mode evidence along with microscope pictures indicated that the CNF modification acted as a beneficial reinforcement inhibiting interlaminar delamination.

  19. Manufacturing and Shear Response Characterization of Carbon Nanofiber Modified CFRP Using the Out-of-Autoclave-Vacuum-Bag-Only Cure Process

    PubMed Central

    McDonald, Erin E.; Wallace, Landon F.; Hickman, Gregory J. S.; Hsiao, Kuang-Ting

    2014-01-01

    The interlaminar shear response is studied for carbon nanofiber (CNF) modified out-of-autoclave-vacuum-bag-only (OOA-VBO) carbon fiber reinforced plastic (CFRP). Commercial OOA-VBO prepregs were coated with a CNF modified epoxy solution and a control epoxy solution without CNF to make CNF modified samples and control samples, respectively. Tensile testingwas used to study the in-plane shear performance of [±45°]4s composite laminates. Significant difference in failure modes between the control and CNF modified CFRPs was identified. The control samples experienced half-plane interlaminar delamination, whereas the CNF modified samples experienced a localized failure in the intralaminar region. Digital image correlation (DIC) surface strain results of the control sample showed no further surface strain increase along the delaminated section when the sample was further elongated prior to sample failure. On the other hand, the DIC results of the CNF modified sample showed that the surface strain increased relatively and uniformly across the CFRP as the sample was further elongated until sample failure. The failure mode evidence along with microscope pictures indicated that the CNF modification acted as a beneficial reinforcement inhibiting interlaminar delamination. PMID:24688435

  20. Optimal Digital Controller Design for a Servo Motor Taking Account of Intersample Behavior

    NASA Astrophysics Data System (ADS)

    Akiyoshi, Tatsuro; Imai, Jun; Funabiki, Shigeyuki

    A continuous-time plant with discretized continuous-time controller do not yield stability if the sampling rate is lower than some certain level. Thus far, high functioning electronic control has made use of high cost hardwares which are needed to implement discretized continuous-time controllers, while low cost hardwares generally do not have high enough sampling rate. This technical note presents results comparing performance indices with and without intersample behavior, and some answer to the question how a low specification device can control a plant effectively. We consider a machine simulating wafer handling robots at semiconductor factories, which is an electromechanical system driven by a direct drive motor. We illustrate controller design for the robot with and without intersample behavior, and simulations and experimental results by using these controllers. Taking intersample behavior into account proves to be effective to make control performance better and enables it to choose relatively long sampling period. By controller design via performance index with intersample behavior, we can cope with situation where short enough sampling period may not be employed, and freedom of controller design might be widened especially on choice of sampling period.

  1. Pituitary gland volumes in bipolar disorder.

    PubMed

    Clark, Ian A; Mackay, Clare E; Goodwin, Guy M

    2014-12-01

    Bipolar disorder has been associated with increased Hypothalamic-Pituitary-Adrenal axis function. The mechanism is not well understood, but there may be associated increases in pituitary gland volume (PGV) and these small increases may be functionally significant. However, research investigating PGV in bipolar disorder reports mixed results. The aim of the current study was twofold. First, to assess PGV in two novel samples of patients with bipolar disorder and matched healthy controls. Second, to perform a meta-analysis comparing PGV across a larger sample of patients and matched controls. Sample 1 consisted of 23 established patients and 32 matched controls. Sample 2 consisted of 39 medication-naïve patients and 42 matched controls. PGV was measured on structural MRI scans. Seven further studies were identified comparing PGV between patients and matched controls (total n; 244 patients, 308 controls). Both novel samples showed a small (approximately 20mm(3) or 4%), but non-significant, increase in PGV in patients. Combining the two novel samples showed a significant association of age and PGV. Meta-analysis showed a trend towards a larger pituitary gland in patients (effect size: .23, CI: -.14, .59). While results suggest a possible small difference in pituitary gland volume between patients and matched controls, larger mega-analyses with sample sizes greater even than those used in the current meta-analysis are still required. There is a small but potentially functionally significant increase in PGV in patients with bipolar disorder compared to controls. Results demonstrate the difficulty of finding potentially important but small effects in functional brain disorders. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Multi-laboratory survey of qPCR enterococci analysis method performance

    EPA Pesticide Factsheets

    Quantitative polymerase chain reaction (qPCR) has become a frequently used technique for quantifying enterococci in recreational surface waters, but there are several methodological options. Here we evaluated how three method permutations, type of mastermix, sample extract dilution and use of controls in results calculation, affect method reliability among multiple laboratories with respect to sample interference. Multiple samples from each of 22 sites representing an array of habitat types were analyzed using EPA Method 1611 and 1609 reagents with full strength and five-fold diluted extracts. The presence of interference was assessed three ways: using sample processing and PCR amplifications controls; consistency of results across extract dilutions; and relative recovery of target genes from spiked enterococci in water sample compared to control matrices with acceptable recovery defined as 50 to 200%. Method 1609, which is based on an environmental mastermix, was found to be superior to Method 1611, which is based on a universal mastermix. Method 1611 had over a 40% control assay failure rate with undiluted extracts and a 6% failure rate with diluted extracts. Method 1609 failed in only 11% and 3% of undiluted and diluted extracts analyses. Use of sample processing control assay results in the delta-delta Ct method for calculating relative target gene recoveries increased the number of acceptable recovery results. Delta-delta tended to bias recoveries fr

  3. Detection of herpes simplex virus and varicella-zoster virus in clinical swabs: frequent inhibition of PCR as determined by internal controls.

    PubMed

    Bezold, G; Volkenandt, M; Gottlöber, P; Peter, R U

    2000-12-01

    PCR-based detection of microorganisms is widely used for diagnostic purposes. Most routine PCR applications do not control for inhibition of PCR, thus leading to false-negative results. One hundred eighteen swab samples obtained from skin and mucosa were investigated for the presence of herpes simplex virus (HSV), varicella-zoster virus (VZV), and the control gene betaglobin by internally controlled PCR with purified and unpurified DNA in parallel. With unpurified DNA, inhibition of PCR was detected in 23% of betaglobin PCRs, 25% of VZV PCRs, and 16% of HSV PCRs versus 3% each for purified DNA. Approximately 20% of the samples with positive results for HSV or VZV had negative or inhibited results using unpurified DNA. These results indicate that PCR from clinical swab specimens should be performed exclusively with internal controls because the positive control alone cannot exclude PCR inhibition in individual samples. Purification of DNA will decrease, but not exclude, PCR inhibition.

  4. Digital-computer normal shock position and restart control of a Mach 2.5 axisymmetric mixed-compression inlet

    NASA Technical Reports Server (NTRS)

    Neiner, G. H.; Cole, G. L.; Arpasi, D. J.

    1972-01-01

    Digital computer control of a mixed-compression inlet is discussed. The inlet was terminated with a choked orifice at the compressor face station to dynamically simulate a turbojet engine. Inlet diffuser exit airflow disturbances were used. A digital version of a previously tested analog control system was used for both normal shock and restart control. Digital computer algorithms were derived using z-transform and finite difference methods. Using a sample rate of 1000 samples per second, the digital normal shock and restart controls essentially duplicated the inlet analog computer control results. At a sample rate of 100 samples per second, the control system performed adequately but was less stable.

  5. Effects of orbital exposure on Halar during the LDEF mission

    NASA Technical Reports Server (NTRS)

    Brower, William E., Jr.; Holla, Harish; Bauer, Robert A.

    1992-01-01

    Thermomechanical Analysis (TMA), Differential Scanning Calorimetry (DSC), and Thermogravimetric Analysis (TGA) were performed on samples of Halar exposed on the LDEF Mission for 6 years in orbit and unexposed Halar control samples. Sections 10-100 microns thick were removed from the exposed surface down to a depth of 1,000 microns through the 3 mm thick samples. The TMA and DSC results, which arise from the entire slice and not just its surface, showed no differences between the LDEF and the control samples. TMA scans were run from ambient to 300 C; results were compared by a tabulation of the glass transition temperatures. DSC scans were run from ambient to 700 C; the enthalpy of melting was compared for the samples as a function of section depth with the sample. The TGA results, which arise from the surface of the sample initially, showed a sharp increase in the topmost 50 micron section (the exposed, discolored side) in the weight loss of 170 C in oxygen. This weight loss dropped to bulk values in the range of depth of 50-200 microns. The control sample showed only a slight increase in weight loss as the top surface was approached. The LDEF Halar sample appears to be mechanically undamaged, with a surface layer which oxidizes faster as a result of orbital exposure.

  6. Adjusting for outcome misclassification: the importance of accounting for case-control sampling and other forms of outcome-related selection.

    PubMed

    Jurek, Anne M; Maldonado, George; Greenland, Sander

    2013-03-01

    Special care must be taken when adjusting for outcome misclassification in case-control data. Basic adjustment formulas using either sensitivity and specificity or predictive values (as with external validation data) do not account for the fact that controls are sampled from a much larger pool of potential controls. A parallel problem arises in surveys and cohort studies in which participation or loss is outcome related. We review this problem and provide simple methods to adjust for outcome misclassification in case-control studies, and illustrate the methods in a case-control birth certificate study of cleft lip/palate and maternal cigarette smoking during pregnancy. Adjustment formulas for outcome misclassification that ignore case-control sampling can yield severely biased results. In the data we examined, the magnitude of error caused by not accounting for sampling is small when population sensitivity and specificity are high, but increases as (1) population sensitivity decreases, (2) population specificity decreases, and (3) the magnitude of the differentiality increases. Failing to account for case-control sampling can result in an odds ratio adjusted for outcome misclassification that is either too high or too low. One needs to account for outcome-related selection (such as case-control sampling) when adjusting for outcome misclassification using external information. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. NHEXAS PHASE I ARIZONA STUDY--QA ANALYTICAL RESULTS FOR METALS IN SPIKE SAMPLES

    EPA Science Inventory

    The Metals in Spike Samples data set contains the analytical results of measurements of up to 11 metals in 38 control samples (spikes) from 18 households. Measurements were made in spiked samples of dust, food, beverages, blood, urine, and dermal wipe residue. Spiked samples we...

  8. NHEXAS PHASE I ARIZONA STUDY--QA ANALYTICAL RESULTS FOR PESTICIDE METABOLITES IN SPIKE SAMPLES

    EPA Science Inventory

    The Pesticide Metabolites in Spike Samples data set contains the analytical results of measurements of up to 4 pesticide metabolites in 3 control samples (spikes) from 3 households. Measurements were made in spiked samples of urine. Spiked samples were used to assess recovery o...

  9. Radiation and temperature effects on LDEF fiber optic samples

    NASA Technical Reports Server (NTRS)

    Johnston, A. R.; Hartmayer, R.; Bergman, L. A.

    1993-01-01

    Results obtained from the JPL Fiber Optics Long Duration Exposure Facility (LDEF) Experiment since the June 1991 Experimenters' Workshop are addressed. Radiation darkening of laboratory control samples and the subsequent annealing was measured in the laboratory for the control samples. The long-time residual loss was compared to the LDEF flight samples and found to be in agreement. The results of laboratory temperature tests on the flight samples, extending over a period of about nine years, including the pre-flight and post-flight analysis periods, are described. The temperature response of the different cable samples varies widely, and appears in two samples to be affected by polymer aging. Conclusions to date are summarized.

  10. Chemometric techniques on the analysis of Raman spectra of serum blood samples of breast cancer patients

    NASA Astrophysics Data System (ADS)

    Rocha-Osornio, L. N.; Pichardo-Molina, J. L.; Barbosa-Garcia, O.; Frausto-Reyes, C.; Araujo-Andrade, C.; Huerta-Franco, R.; Gutiérrez-Juárez, G.

    2008-02-01

    Raman spectroscopy and Multivariate methods were used to study serum blood samples of control and breast cancer patients. Blood samples were obtained from 11 patients and 12 controls from the central region of Mexico. Our results show that principal component analysis is able to discriminate serum sample of breast cancer patients from those of control group, also the loading vectors of PCA plotted as a function of Raman shift shown which bands permitted to make the maximum discrimination between both groups of samples.

  11. Aerosol sampling system for collection of Capstone depleted uranium particles in a high-energy environment.

    PubMed

    Holmes, Thomas D; Guilmette, Raymond A; Cheng, Yung Sung; Parkhurst, Mary Ann; Hoover, Mark D

    2009-03-01

    The Capstone Depleted Uranium (DU) Aerosol Study was undertaken to obtain aerosol samples resulting from a large-caliber DU penetrator striking an Abrams or Bradley test vehicle. The sampling strategy was designed to (1) optimize the performance of the samplers and maintain their integrity in the extreme environment created during perforation of an armored vehicle by a DU penetrator, (2) collect aerosols as a function of time post perforation, and (3) obtain size-classified samples for analysis of chemical composition, particle morphology, and solubility in lung fluid. This paper describes the experimental setup and sampling methodologies used to achieve these objectives. Custom-designed arrays of sampling heads were secured to the inside of the target in locations approximating the breathing zones of the crew locations in the test vehicles. Each array was designed to support nine filter cassettes and nine cascade impactors mounted with quick-disconnect fittings. Shielding and sampler placement strategies were used to minimize sampler loss caused by the penetrator impact and the resulting fragments of eroded penetrator and perforated armor. A cyclone train was used to collect larger quantities of DU aerosol for measurement of chemical composition and solubility. A moving filter sample was used to obtain semicontinuous samples for DU concentration determination. Control for the air samplers was provided by five remotely located valve control and pressure monitoring units located inside and around the test vehicle. These units were connected to a computer interface chassis and controlled using a customized LabVIEW engineering computer control program. The aerosol sampling arrays and control systems for the Capstone study provided the needed aerosol samples for physicochemical analysis, and the resultant data were used for risk assessment of exposure to DU aerosol.

  12. Aerosol Sampling System for Collection of Capstone Depleted Uranium Particles in a High-Energy Environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holmes, Thomas D.; Guilmette, Raymond A.; Cheng, Yung-Sung

    2009-03-01

    The Capstone Depleted Uranium Aerosol Study was undertaken to obtain aerosol samples resulting from a kinetic-energy cartridge with a large-caliber depleted uranium (DU) penetrator striking an Abrams or Bradley test vehicle. The sampling strategy was designed to (1) optimize the performance of the samplers and maintain their integrity in the extreme environment created during perforation of an armored vehicle by a DU penetrator, (2) collect aerosols as a function of time post-impact, and (3) obtain size-classified samples for analysis of chemical composition, particle morphology, and solubility in lung fluid. This paper describes the experimental setup and sampling methodologies used tomore » achieve these objectives. Custom-designed arrays of sampling heads were secured to the inside of the target in locations approximating the breathing zones of the vehicle commander, loader, gunner, and driver. Each array was designed to support nine filter cassettes and nine cascade impactors mounted with quick-disconnect fittings. Shielding and sampler placement strategies were used to minimize sampler loss caused by the penetrator impact and the resulting fragments of eroded penetrator and perforated armor. A cyclone train was used to collect larger quantities of DU aerosol for chemical composition and solubility. A moving filter sample was used to obtain semicontinuous samples for depleted uranium concentration determination. Control for the air samplers was provided by five remotely located valve control and pressure monitoring units located inside and around the test vehicle. These units were connected to a computer interface chassis and controlled using a customized LabVIEW engineering computer control program. The aerosol sampling arrays and control systems for the Capstone study provided the needed aerosol samples for physicochemical analysis, and the resultant data were used for risk assessment of exposure to DU aerosol.« less

  13. Nonlinear discrete-time multirate adaptive control of non-linear vibrations of smart beams

    NASA Astrophysics Data System (ADS)

    Georgiou, Georgios; Foutsitzi, Georgia A.; Stavroulakis, Georgios E.

    2018-06-01

    The nonlinear adaptive digital control of a smart piezoelectric beam is considered. It is shown that in the case of a sampled-data context, a multirate control strategy provides an appropriate framework in order to achieve vibration regulation, ensuring the stability of the whole control system. Under parametric uncertainties in the model parameters (damping ratios, frequencies, levels of non linearities and cross coupling, control input parameters), the scheme is completed with an adaptation law deduced from hyperstability concepts. This results in the asymptotic satisfaction of the control objectives at the sampling instants. Simulation results are presented.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Plemons, R.E.; Hopwood, W.H. Jr.; Hamilton, J.H.

    For a number of years the Oak Ridge Y-12 Plant Laboratory has been analyzing coal predominately for the utilities department of the Y-12 Plant. All laboratory procedures, except a Leco sulfur method which used the Leco Instruction Manual as a reference, were written based on the ASTM coal analyses. Sulfur is analyzed at the present time by two methods, gravimetric and Leco. The laboratory has two major endeavors for monitoring the quality of its coal analyses. (1) A control program by the Plant Statistical Quality Control Department. Quality Control submits one sample for every nine samples submitted by the utilitiesmore » departments and the laboratory analyzes a control sample along with the utilities samples. (2) An exchange program with the DOE Coal Analysis Laboratory in Bruceton, Pennsylvania. The Y-12 Laboratory submits to the DOE Coal Laboratory, on even numbered months, a sample that Y-12 has analyzed. The DOE Coal Laboratory submits, on odd numbered months, one of their analyzed samples to the Y-12 Plant Laboratory to be analyzed. The results of these control and exchange programs are monitored not only by laboratory personnel, but also by Statistical Quality Control personnel who provide statistical evaluations. After analysis and reporting of results, all utilities samples are retained by the laboratory until the coal contracts have been settled. The utilities departments have responsibility for the initiation and preparation of the coal samples. The samples normally received by the laboratory have been ground to 4-mesh, reduced to 0.5-gallon quantities, and sealed in air-tight containers. Sample identification numbers and a Request for Analysis are generated by the utilities departments.« less

  15. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--QA ANALYTICAL RESULTS FOR METALS IN SPIKE SAMPLES

    EPA Science Inventory

    The Metals in Spike Samples data set contains the analytical results of measurements of up to 11 metals in 15 control samples (spikes) from 11 households. Measurements were made in spiked samples of dust, food, and dermal wipe residue. Spiked samples were used to assess recover...

  16. A Feedfordward Adaptive Controller to Reduce the Imaging Time of Large-Sized Biological Samples with a SPM-Based Multiprobe Station

    PubMed Central

    Otero, Jorge; Guerrero, Hector; Gonzalez, Laura; Puig-Vidal, Manel

    2012-01-01

    The time required to image large samples is an important limiting factor in SPM-based systems. In multiprobe setups, especially when working with biological samples, this drawback can make impossible to conduct certain experiments. In this work, we present a feedfordward controller based on bang-bang and adaptive controls. The controls are based in the difference between the maximum speeds that can be used for imaging depending on the flatness of the sample zone. Topographic images of Escherichia coli bacteria samples were acquired using the implemented controllers. Results show that to go faster in the flat zones, rather than using a constant scanning speed for the whole image, speeds up the imaging process of large samples by up to a 4× factor. PMID:22368491

  17. Failure to replicate depletion of self-control.

    PubMed

    Xu, Xiaomeng; Demos, Kathryn E; Leahey, Tricia M; Hart, Chantelle N; Trautvetter, Jennifer; Coward, Pamela; Middleton, Kathryn R; Wing, Rena R

    2014-01-01

    The limited resource or strength model of self-control posits that the use of self-regulatory resources leads to depletion and poorer performance on subsequent self-control tasks. We conducted four studies (two with community samples, two with young adult samples) utilizing a frequently used depletion procedure (crossing out letters protocol) and the two most frequently used dependent measures of self-control (handgrip perseverance and modified Stroop). In each study, participants completed a baseline self-control measure, a depletion or control task (randomized), and then the same measure of self-control a second time. There was no evidence for significant depletion effects in any of these four studies. The null results obtained in four attempts to replicate using strong methodological approaches may indicate that depletion has more limited effects than implied by prior publications. We encourage further efforts to replicate depletion (particularly among community samples) with full disclosure of positive and negative results.

  18. A novel personal air sampling device for collecting volatile organic compounds: a comparison to charcoal tubes and diffusive badges.

    PubMed

    Rossner, Alan; Farant, Jean-Pierre

    2004-02-01

    Evacuated canisters have been used for many years to collect ambient air samples for gases and vapors. Recently, significant interest has arisen in using evacuated canisters for personal breathing zone sampling as an alternative to sorbent sampling. A novel flow control device was designed and built at McGill University. The flow control device was designed to provide a very low flow rate, <0.5 mL/min, to allow a sample to be collected over an extended period of time. Previous experiments run at McGill have shown agreement between the mathematical and empirical models to predict flow rate. The flow control device combined with an evacuated canister (capillary flow control-canister) was used in a series of experiments to evaluate its performance against charcoal tubes and diffusive badges. Air samples of six volatile organic compounds were simultaneously collected in a chamber using the capillary flow control-canister, charcoal tubes, and diffusive badges. Five different concentrations of the six volatile organic compounds were evaluated. The results from the three sampling devices were compared to each other and to concentration values obtained using an online gas chromatograph (GC). Eighty-four samples of each method were collected for each of the six chemicals. Results indicate that the capillary flow control-canister device compares quite favorably to the online GC and to the charcoal tubes, p > 0.05 for most of the tests. The capillary flow control-canister was found to be more accurate for the compounds evaluated, easier to use, and easier to analyze than charcoal tubes and passive dosimeter badges.

  19. Field-based random sampling without a sampling frame: control selection for a case-control study in rural Africa.

    PubMed

    Crampin, A C; Mwinuka, V; Malema, S S; Glynn, J R; Fine, P E

    2001-01-01

    Selection bias, particularly of controls, is common in case-control studies and may materially affect the results. Methods of control selection should be tailored both for the risk factors and disease under investigation and for the population being studied. We present here a control selection method devised for a case-control study of tuberculosis in rural Africa (Karonga, northern Malawi) that selects an age/sex frequency-matched random sample of the population, with a geographical distribution in proportion to the population density. We also present an audit of the selection process, and discuss the potential of this method in other settings.

  20. Stabilization for sampled-data neural-network-based control systems.

    PubMed

    Zhu, Xun-Lin; Wang, Youyi

    2011-02-01

    This paper studies the problem of stabilization for sampled-data neural-network-based control systems with an optimal guaranteed cost. Unlike previous works, the resulting closed-loop system with variable uncertain sampling cannot simply be regarded as an ordinary continuous-time system with a fast-varying delay in the state. By defining a novel piecewise Lyapunov functional and using a convex combination technique, the characteristic of sampled-data systems is captured. A new delay-dependent stabilization criterion is established in terms of linear matrix inequalities such that the maximal sampling interval and the minimal guaranteed cost control performance can be obtained. It is shown that the newly proposed approach can lead to less conservative and less complex results than the existing ones. Application examples are given to illustrate the effectiveness and the benefits of the proposed method.

  1. Genome-wide association analysis of secondary imaging phenotypes from the Alzheimer's disease neuroimaging initiative study.

    PubMed

    Zhu, Wensheng; Yuan, Ying; Zhang, Jingwen; Zhou, Fan; Knickmeyer, Rebecca C; Zhu, Hongtu

    2017-02-01

    The aim of this paper is to systematically evaluate a biased sampling issue associated with genome-wide association analysis (GWAS) of imaging phenotypes for most imaging genetic studies, including the Alzheimer's Disease Neuroimaging Initiative (ADNI). Specifically, the original sampling scheme of these imaging genetic studies is primarily the retrospective case-control design, whereas most existing statistical analyses of these studies ignore such sampling scheme by directly correlating imaging phenotypes (called the secondary traits) with genotype. Although it has been well documented in genetic epidemiology that ignoring the case-control sampling scheme can produce highly biased estimates, and subsequently lead to misleading results and suspicious associations, such findings are not well documented in imaging genetics. We use extensive simulations and a large-scale imaging genetic data analysis of the Alzheimer's Disease Neuroimaging Initiative (ADNI) data to evaluate the effects of the case-control sampling scheme on GWAS results based on some standard statistical methods, such as linear regression methods, while comparing it with several advanced statistical methods that appropriately adjust for the case-control sampling scheme. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Rock sampling. [apparatus for controlling particle size

    NASA Technical Reports Server (NTRS)

    Blum, P. (Inventor)

    1971-01-01

    An apparatus for sampling rock and other brittle materials and for controlling resultant particle sizes is described. The device includes grinding means for cutting grooves in the rock surface and to provide a grouping of thin, shallow, parallel ridges and cutter means to reduce these ridges to a powder specimen. Collection means is provided for the powder. The invention relates to rock grinding and particularly to the sampling of rock specimens with good size control.

  3. I/O impedance controller

    DOEpatents

    Ruesch, Rodney; Jenkins, Philip N.; Ma, Nan

    2004-03-09

    There is disclosed apparatus and apparatus for impedance control to provide for controlling the impedance of a communication circuit using an all-digital impedance control circuit wherein one or more control bits are used to tune the output impedance. In one example embodiment, the impedance control circuit is fabricated using circuit components found in a standard macro library of a computer aided design system. According to another example embodiment, there is provided a control for an output driver on an integrated circuit ("IC") device to provide for forming a resistor divider network with the output driver and a resistor off the IC device so that the divider network produces an output voltage, comparing the output voltage of the divider network with a reference voltage, and adjusting the output impedance of the output driver to attempt to match the output voltage of the divider network and the reference voltage. Also disclosed is over-sampling the divider network voltage, storing the results of the over sampling, repeating the over-sampling and storing, averaging the results of multiple over sampling operations, controlling the impedance with a plurality of bits forming a word, and updating the value of the word by only one least significant bit at a time.

  4. Prediction-based sampled-data H∞ controller design for attitude stabilisation of a rigid spacecraft with disturbances

    NASA Astrophysics Data System (ADS)

    Zhu, Baolong; Zhang, Zhiping; Zhou, Ding; Ma, Jie; Li, Shunli

    2017-08-01

    This paper investigates the H∞ control problem of the attitude stabilisation of a rigid spacecraft with external disturbances using prediction-based sampled-data control strategy. Aiming to achieve a 'virtual' closed-loop system, a type of parameterised sampled-data controller is designed by introducing a prediction mechanism. The resultant closed-loop system is equivalent to a hybrid system featured by a continuous-time and an impulsive differential system. By using a time-varying Lyapunov functional, a generalised bounded real lemma (GBRL) is first established for a kind of impulsive differential system. Based on this GBRL and Lyapunov functional approach, a sufficient condition is derived to guarantee the closed-loop system to be asymptotically stable and to achieve a prescribed H∞ performance. In addition, the controller parameter tuning is cast into a convex optimisation problem. Simulation and comparative results are provided to illustrate the effectiveness of the developed control scheme.

  5. [Investigation on the homogeneity and stability of quality controlling cosmetic samples containing arsenic].

    PubMed

    Dong, Bing; Song, Yu; Fan, Wenjia; Zhu, Ying

    2010-11-01

    To study the homogeneity and stability of arsenic in quality controlling cosmetic samples. Arsenic was determined by atomic fluorescence spectrophotometric method. The t-test and F-test were used to evaluate the significant difference of the within-bottle and between-bottle results with three batches. The RSDs of arsenic obtained in different time were compared with the relative expanding uncertainties to evaluate the stability. Average and variance of within-bottle and between-bottle results of arsenic were not different significantly. The RSDs of Arsenic were less than the relative expanding uncertainties. Quality controlling cosmetic samples containing arsenic were considered homogeneous and stable.

  6. Analysis of Tank 38H (HTF-38-17-52, -53) and Tank 43H (HTF-43-17-54, -55) Samples for Support of the Enrichment Control and Corrosion Control Programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hay, M.; Coleman, C.; Diprete, D.

    SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The total uranium in the Tank 38H surface sample was 41.3 mg/L while the sub-surface sample was 43.5 mg/L. The Tank 43H samples contained total uranium concentrations of 28.5 mg/L in the surface sample and 28.1 mg/L in the sub-surface sample. The U-235 percentage ranged from 0.62% to 0.63% for the Tank 38H samples and Tank 43H samples. The total uranium and percent U-235 results in the table appear slightly lower than recent Tank 38H and Tank 43H uranium measurements. The plutonium results in the tablemore » show a large difference between the surface and sub-surface sample concentrations for Tank 38H. The Tank 43H plutonium results closely match the range of values measured on previous samples. The Cs-137 results for the Tank 38H surface and sub-surface samples show similar concentrations slightly higher than the concentrations measured in recent samples. The Cs-137 results for the two Tank 43H samples also show similar concentrations within the range of values measured on previous samples. The four samples show silicon concentrations somewhat lower than the previous samples with values ranging from 124 to 168 mg/L.« less

  7. Analysis of tank 38H (HTF-38-17-18, -19) and tank 43H (HTF-43-17-20, -21) samples for support of the enrichment control and corrosion control programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hay, M. S.; Coleman, C. J.; Diprete, D. P.

    SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The total uranium in the Tank 38H samples ranged from 53.7 mg/L for the surface sample to 57.0 mg/L in the sub-surface sample. The Tank 43H samples showed uranium concentrations of 46.2 mg/L for the surface sample and 45.7 mg/L in the sub-surface sample. The U-235 percentage was 0.63% in the Tank 38H samples and 0.62% in the Tank 43H samples. The total uranium and percent U-235 results appear consistent with recent Tank 38H and Tank 43H uranium measurements. The plutonium results for the Tank 38Hmore » surface sample are slightly higher than recent sample results, while the Tank 43H plutonium results are within the range of values measured on previous samples. The Cs-137 results for the Tank 38H surface and subsurface samples are slightly higher than the concentrations measured in recent samples. The Cs-137 results for the two Tank 43H samples are within the range of values measured on previous samples. The comparison of the sum of the cations in each sample versus the sum of the anions shows a difference of 23% for the Tank 38H surface sample and 18% for the Tank 43H surface sample. The four samples show silicon concentrations somewhat lower than the previous samples with values ranging from 80.2 to 105 mg/L.« less

  8. Analysis of tank 4 (FTF-4-15-22, 23) surface and subsurface supernatant samples in support of enrichment control, corrosion control and evaporator feed qualification programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oji, L. N.

    This report provides the results of analyses on Savannah River Site Tank 4 surface and subsurface supernatant liquid samples in support of the Enrichment Control Program (ECP), the Corrosion Control Program (CCP) and the Evaporator Feed Qualification (EFQ) Program. The purpose of the ECP sample taken from Tank 4 in August 2015 was to determine if the supernatant liquid would be “acceptable feed” to the 2H and 3H evaporator systems.

  9. Indicator organisms in meat and poultry slaughter operations: their potential use in process control and the role of emerging technologies.

    PubMed

    Saini, Parmesh K; Marks, Harry M; Dreyfuss, Moshe S; Evans, Peter; Cook, L Victor; Dessai, Uday

    2011-08-01

    Measuring commonly occurring, nonpathogenic organisms on poultry products may be used for designing statistical process control systems that could result in reductions of pathogen levels. The extent of pathogen level reduction that could be obtained from actions resulting from monitoring these measurements over time depends upon the degree of understanding cause-effect relationships between processing variables, selected output variables, and pathogens. For such measurements to be effective for controlling or improving processing to some capability level within the statistical process control context, sufficiently frequent measurements would be needed to help identify processing deficiencies. Ultimately the correct balance of sampling and resources is determined by those characteristics of deficient processing that are important to identify. We recommend strategies that emphasize flexibility, depending upon sampling objectives. Coupling the measurement of levels of indicator organisms with practical emerging technologies and suitable on-site platforms that decrease the time between sample collections and interpreting results would enhance monitoring process control.

  10. Endogenous levels of nitrites and nitrates in wide consumption foodstuffs: Results of five years of official controls and monitoring.

    PubMed

    Iammarino, Marco; Di Taranto, Aurelia; Cristino, Marianna

    2013-10-15

    The massive introduction of nitrogen fertilisers, necessary to maximise the global food production, has brought about an increase of the residual amounts of nitrites and nitrates in the products. Notoriously, these compounds may exercise toxic effects. In this work the results obtained from 5years of official controls and monitoring focused on tracing quantifiable amounts of nitrites and nitrates in 1785 samples of meat, dairy, fish products and leafy vegetables are reported. A widespread presence of nitrates at low concentrations in foodstuffs was verified. High concentrations of nitrates were registered in some leafy vegetables and mussels samples, while high nitrites concentrations were registered in some spinach samples. The results confirmed the necessity to develop most controls and suggest the introduction of new legal limits related to some combinations contaminant/matrix. Such new limits may fill legislative gaps that may cause wrong interpretations of the results obtained during official controls. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Type I error probabilities based on design-stage strategies with applications to noninferiority trials.

    PubMed

    Rothmann, Mark

    2005-01-01

    When testing the equality of means from two different populations, a t-test or large sample normal test tend to be performed. For these tests, when the sample size or design for the second sample is dependent on the results of the first sample, the type I error probability is altered for each specific possibility in the null hypothesis. We will examine the impact on the type I error probabilities for two confidence interval procedures and procedures using test statistics when the design for the second sample or experiment is dependent on the results from the first sample or experiment (or series of experiments). Ways for controlling a desired maximum type I error probability or a desired type I error rate will be discussed. Results are applied to the setting of noninferiority comparisons in active controlled trials where the use of a placebo is unethical.

  12. The effect of different control point sampling sequences on convergence of VMAT inverse planning

    NASA Astrophysics Data System (ADS)

    Pardo Montero, Juan; Fenwick, John D.

    2011-04-01

    A key component of some volumetric-modulated arc therapy (VMAT) optimization algorithms is the progressive addition of control points to the optimization. This idea was introduced in Otto's seminal VMAT paper, in which a coarse sampling of control points was used at the beginning of the optimization and new control points were progressively added one at a time. A different form of the methodology is also present in the RapidArc optimizer, which adds new control points in groups called 'multiresolution levels', each doubling the number of control points in the optimization. This progressive sampling accelerates convergence, improving the results obtained, and has similarities with the ordered subset algorithm used to accelerate iterative image reconstruction. In this work we have used a VMAT optimizer developed in-house to study the performance of optimization algorithms which use different control point sampling sequences, most of which fall into three different classes: doubling sequences, which add new control points in groups such that the number of control points in the optimization is (roughly) doubled; Otto-like progressive sampling which adds one control point at a time, and equi-length sequences which contain several multiresolution levels each with the same number of control points. Results are presented in this study for two clinical geometries, prostate and head-and-neck treatments. A dependence of the quality of the final solution on the number of starting control points has been observed, in agreement with previous works. We have found that some sequences, especially E20 and E30 (equi-length sequences with 20 and 30 multiresolution levels, respectively), generate better results than a 5 multiresolution level RapidArc-like sequence. The final value of the cost function is reduced up to 20%, such reductions leading to small improvements in dosimetric parameters characterizing the treatments—slightly more homogeneous target doses and better sparing of the organs at risk.

  13. Economic consequences of improved temperature forecasts: An experiment with the Florida citrus growers (an update of control group results)

    NASA Technical Reports Server (NTRS)

    Braen, C.

    1978-01-01

    The economic experiment, the results obtained to date and the work which still remains to be done are summarized. Specifically, the experiment design is described in detail as are the developed data collection methodology and procedures, sampling plan, data reduction techniques, cost and loss models, establishment of frost severity measures, data obtained from citrus growers, National Weather Service and Federal Crop Insurance Corp. Resulting protection costs and crop losses for the control group sample, extrapolation of results of control group to the Florida citrus industry and the method for normalization of these results to a normal or average frost season so that results may be compared with anticipated similar results from test group measurements are discussed.

  14. Analysis of Tank 38H (HTF-38-15-47, 49) and Tank 43H (HTF-43-15-51, 53) surface and subsurface supernatant samples in support of enrichment and corrosion control programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oji, L. N.

    This report provides the results of analyses on Tanks 38H and 43H surface and subsurface supernatant liquid samples in support of the Enrichment Control Program (ECP) and the Corrosion Control Program (CCP).

  15. Biomechanical and Histologic Evaluation of LifeMesh™: A Novel Self-Fixating Mesh Adhesive.

    PubMed

    Shahan, Charles P; Stoikes, Nathaniel N; Roan, Esra; Tatum, James; Webb, David L; Voeller, Guy R

    2018-04-01

    Mesh fixation with the use of adhesives results in an immediate and total surface area adhesion of the mesh, removing the need for penetrating fixation points. The purpose of this study was to evaluate LifeMesh™, a prototype mesh adhesive technology which coats polypropylene mesh. The strength of the interface between mesh and tissue, inflammatory responses, and histology were measured at varying time points in a swine model, and these results were compared with sutures. Twenty Mongrel swine underwent implantation of LifeMesh™ and one piece of bare polypropylene mesh secured with suture (control). One additional piece of either LifeMesh™ or control was used for histopathologic evaluation. The implants were retrieved at 3, 7, and 14 days. Only 3- and 7-day specimens underwent lap shear testing. On Day 3, LifeMesh™ samples showed considerably less contraction than sutured samples. The interfacial strength of Day 3 LifeMesh™ samples was similar to that of sutured samples. At seven days, LifeMesh™ samples continued to show significantly less contraction than sutured samples. The strength of fixation at seven days was greater in the control samples. The histologic findings were similar in LifeMesh™ and control samples. LifeMesh™ showed significantly less contraction than sutured samples at all measured time points. Although fixation strength was similar at three days, the interfacial strength of LifeMesh™ remained unchanged, whereas sutured controls increased by day 7. With histologic equivalence, considerably less contraction, and similar early fixation strength, LifeMesh™ is a viable mesh fixation technology.

  16. Antibacterial properties of nano-silver coated PEEK prepared through magnetron sputtering.

    PubMed

    Liu, Xiuju; Gan, Kang; Liu, Hong; Song, Xiaoqing; Chen, Tianjie; Liu, Chenchen

    2017-09-01

    We aimed to investigate the cytotoxicity and antibacterial properties of nano-silver-coated polyetheretherketone (PEEK) produced through magnetron sputtering and provide a theoretical basis for its use in clinical applications. The surfaces of PEEKs were coated with nano-silver at varying thicknesses (3, 6, 9, and 12nm) through magnetron sputtering technology. The resulting coated PEEK samples were classified into the following groups according to the thickness of the nano-silver coating: PEEK-3 (3nm), PEEK-6 (6nm), PEEK-9 (9nm), PEEK-12 (12nm), and PEEK control group. The surface microstructure and composition of each sample were observed by scanning electron microscopy (SEM), atomic force microscopy (AFM), and energy dispersive spectrum (EDS) analysis. The water contact angle of each sample was then measured by contact angle meters. A cell counting kit (CCK-8) was used to analyze the cytotoxicity of the mouse fibroblast cells (L929) in the coated groups (n=5) and group test samples (n=6), negative control (polyethylene, PE) (n=6), and positive control group (phenol) (n=6). The antibacterial properties of the samples were tested by co-culturing Streptococcus mutans and Straphylococcus aureus. The bacteria that adhered to the surface of samples were observed by SEM. The antibacterial adhesion ability of each sample was then evaluated. SEM and AFM analysis results showed that the surfaces of control group samples were smooth but compact. Homogeneous silver nano-particles (AgNPs) and nano-silver coating were uniformly distributed on the surface of the coated group samples. Compared with the control samples, the nano-silver coated samples had a significant increase in surface roughness (P<0.05) as the thickness of their nano-silver coating increased. EDS analysis showed that not only C and O but also Ag were present on the surface of the coated samples. Moreover, the water contact angle of modified samples significantly increased after nano-silver coating modification (P<0.01). CCK-8 cytotoxicity test results showed that coated samples did not exhibit cytotoxicity. The antibacterial experimental results showed that the nano-silver coating can significantly improve the antibacterial activity and bacterial adhesion ability of the PEEK samples. The compact and homogeneous nano-silver coating was successfully prepared on the surface of PEEK through magnetron sputtering. The nano-silver coated PEEKs demonstrated enhanced antibacterial activities and bacterial adhesion abilities and had no cytotoxic effects. Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  17. Sampling methods to the statistical control of the production of blood components.

    PubMed

    Pereira, Paulo; Seghatchian, Jerard; Caldeira, Beatriz; Santos, Paula; Castro, Rosa; Fernandes, Teresa; Xavier, Sandra; de Sousa, Gracinda; de Almeida E Sousa, João Paulo

    2017-12-01

    The control of blood components specifications is a requirement generalized in Europe by the European Commission Directives and in the US by the AABB standards. The use of a statistical process control methodology is recommended in the related literature, including the EDQM guideline. The control reliability is dependent of the sampling. However, a correct sampling methodology seems not to be systematically applied. Commonly, the sampling is intended to comply uniquely with the 1% specification to the produced blood components. Nevertheless, on a purely statistical viewpoint, this model could be argued not to be related to a consistent sampling technique. This could be a severe limitation to detect abnormal patterns and to assure that the production has a non-significant probability of producing nonconforming components. This article discusses what is happening in blood establishments. Three statistical methodologies are proposed: simple random sampling, sampling based on the proportion of a finite population, and sampling based on the inspection level. The empirical results demonstrate that these models are practicable in blood establishments contributing to the robustness of sampling and related statistical process control decisions for the purpose they are suggested for. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Efficacies of soy sauce and wine base marinades for controlling spoilage of raw beef.

    PubMed

    Kargiotou, C; Katsanidis, E; Rhoades, J; Kontominas, M; Koutsoumanis, K

    2011-02-01

    Fresh beef slices were marinated by immersion in marinades based on soy sauce without (SB) or with lactic acid (SBLA) or red wine base without (WB) or with 0.5% v/v oregano essential oil (WBO). For control samples (immersed in saline), a mean increase of 0.9log CFU/cm(2) in total viable counts (TVCs) occurred during the 24h treatment. During marination with WB and SB, mean TVC decreased by 0.7 and 0.3log CFU/cm(2), respectively. The mean decrease in TVC for samples marinated in WBO or SBLA was 1.2log CFU/cm(2). Subsequent storage of beef resulted in a rapid increase of TVC in control samples, to ≥9.5log CFU/cm(2) after 8 days at 5°C or 3 days at 15°C. Significant (P<0.05) microbial growth occurred in marinated samples stored at 5°C. During storage at 15°C TVC increased in only WB samples but the final numbers of 5.9log CFU/cm(2) were significantly lower (P<0.05) than the numbers in the control. Results similar to those for TVC were observed for Pseudomonas spp. All marinades also gave meat with significant lower TBARS values than the controls. There were no significant differences (P>0.05) in the toughness of the marinated samples compared to the control, except for SBLA samples which had significantly higher (P<0.05) shear force values. Marination with soy sauce or red wine marinades can evidently control microbial spoilage and oxidation of meat. Copyright © 2010 Elsevier Ltd. All rights reserved.

  19. Biomarker discovery study design for type 1 diabetes in The Environmental Determinants of Diabetes in the Young (TEDDY) study.

    PubMed

    Lee, Hye-Seung; Burkhardt, Brant R; McLeod, Wendy; Smith, Susan; Eberhard, Chris; Lynch, Kristian; Hadley, David; Rewers, Marian; Simell, Olli; She, Jin-Xiong; Hagopian, Bill; Lernmark, Ake; Akolkar, Beena; Ziegler, Anette G; Krischer, Jeffrey P

    2014-07-01

    The Environmental Determinants of Diabetes in the Young planned biomarker discovery studies on longitudinal samples for persistent confirmed islet cell autoantibodies and type 1 diabetes using dietary biomarkers, metabolomics, microbiome/viral metagenomics and gene expression. This article describes the details of planning The Environmental Determinants of Diabetes in the Young biomarker discovery studies using a nested case-control design that was chosen as an alternative to the full cohort analysis. In the frame of a nested case-control design, it guides the choice of matching factors, selection of controls, preparation of external quality control samples and reduction of batch effects along with proper sample allocation. Our design is to reduce potential bias and retain study power while reducing the costs by limiting the numbers of samples requiring laboratory analyses. It also covers two primary end points (the occurrence of diabetes-related autoantibodies and the diagnosis of type 1 diabetes). The resulting list of case-control matched samples for each laboratory was augmented with external quality control samples. Copyright © 2013 John Wiley & Sons, Ltd.

  20. Effect of lead pollution control on environmental and childhood blood lead level in Nantong, China: an interventional study.

    PubMed

    Chen, Kai; Huang, Lei; Yan, Beizhan; Li, Hongbo; Sun, Hong; Bi, Jun

    2014-11-04

    Children's blood lead levels and prevalence of lead poisoning in China are significantly higher than in developed countries, though a substantial decrease has been observed. Since 2011, strict lead control policies in lead-related industries have been implemented in China, but the success of these policies is unknown. In this study, we collected environmental samples, questionnaire data, and blood samples from 106 children from 1 to 14 years old, before and after implementation of lead-usage control policy in wire rope factories by local government in Zhuhang, Nantong in 2012. Results showed that, one year after the lead control, lead concentrations sharply decreased in both environmental and biological samples with a decrease of 0.43 μg/m3 (-84.3%) in ambient air samples, 0.22 mg/kg (-36.1%) in vegetable samples, 441.1 mg/kg (-43.7%) in dust samples, and 6.24 μg/dL (-51.5%) in childhood blood lead levels (BLL). This study demonstrates the success of lead control policies in promoting the prevention and control of childhood lead poisoning in Nantong, China.

  1. Color compensation in nitrite-reduced meat batters incorporating paprika or tomato paste.

    PubMed

    Bázan-Lugo, Eduardo; García-Martínez, Ignacio; Alfaro-Rodríguez, Rosa Hayde; Totosaus, Alfonso

    2012-06-01

    Nitrite is a key ingredient the manufacture of meat products, forming a stable pink color characteristic of cured products, retarding the development of rancidity and off-odors and flavors during storage, and preventing microbial growth. The negative aspects of nitrite and the demands for healthy foods result in the need to reduce nitrite in cured meat products. Paprika or tomato has been employed as natural pigments in meat products. The objective of this work was to determine the effect of incorporating paprika powder or tomato paste on the texture, rancidity and instrumental and sensory color compensation in nitrite-reduced meat batters. Addition of tomato paste improved moisture content, resulting in harder but less cohesive samples as compared to control and paprika-containing meat batters. Color characteristics of reduced nitrite samples obtained higher a* red coloration (8.9 for paprika and 7.7-8.0 for tomato paste), as compared to control samples (5.65). Instrumental color was low in control samples, with high values for tomato paste and paprika samples. Nonetheless, tomato paste used to compensate color in nitrite-reduced meat batters was ranked closer to the control sample in sensory evaluation. Color characteristics-instrumental and sensory-in these kinds of meat products were enhanced by the addition of 2.5-3.0% of tomato paste, presenting results close to the non-reduced nitrite control. Similarly, antioxidant components of tomato paste or paprika reduced lipid oxidation. Nitrite reduction from 150 to 100 ppm could be achieved employing tomato paste as a natural pigment to improve color and texture. Copyright © 2011 Society of Chemical Industry.

  2. The first 62 AGN observed with SDSS-IV MaNGA - II: resolved stellar populations

    NASA Astrophysics Data System (ADS)

    Mallmann, Nícolas Dullius; Riffel, Rogério; Storchi-Bergmann, Thaisa; Barboza Rembold, Sandro; Riffel, Rogemar A.; Schimoia, Jaderson; da Costa, Luiz Nicolaci; Ávila-Reese, Vladimir; Sanchez, Sebastian F.; Machado, Alice D.; Cirolini, Rafael; Ilha, Gabriele S.; do Nascimento, Janaína C.

    2018-05-01

    We present spatially resolved stellar population age maps, average radial profiles and gradients for the first 62 Active Galactic Nuclei (AGN) observed with SDSS-IV MaNGA to study the effects of the active nuclei on the star formation history of the host galaxies. These results, derived using the STARLIGHT code, are compared with a control sample of non-active galaxies matching the properties of the AGN hosts. We find that the fraction of young stellar populations (SP) in high-luminosity AGN is higher in the inner (R≤0.5 Re) regions when compared with the control sample; low-luminosity AGN, on the other hand, present very similar fractions of young stars to the control sample hosts for the entire studied range (1 Re). The fraction of intermediate age SP of the AGN hosts increases outwards, with a clear enhancement when compared with the control sample. The inner region of the galaxies (AGN and control galaxies) presents a dominant old SP, whose fraction decreases outwards. We also compare our results (differences between AGN and control galaxies) for the early and late-type hosts and find no significant differences. In summary, our results suggest that the most luminous AGN seems to have been triggered by a recent supply of gas that has also triggered recent star formation (t ≤ 40 Myrs) in the central region.

  3. A Proteomic Analysis of Eccrine Sweat: Implications for the Discovery of Schizophrenia Biomarker Proteins

    PubMed Central

    Raiszadeh, Michelle M.; Ross, Mark M.; Russo, Paul S.; Schaepper, Mary Ann H.; Zhou, Weidong; Deng, Jianghong; Ng, Daniel; Dickson, April; Dickson, Cindy; Strom, Monica; Osorio, Carolina; Soeprono, Thomas; Wulfkuhle, Julia D.; Kabbani, Nadine; Petricoin, Emanuel F.; Liotta, Lance A.; Kirsch, Wolff M.

    2012-01-01

    Liquid chromatography tandem mass spectrometry (LC-MS/MS) and multiple reaction monitoring mass spectrometry (MRM-MS) proteomics analyses were performed on eccrine sweat of healthy controls, and the results were compared with those from individuals diagnosed with schizophrenia (SZ). This is the first large scale study of the sweat proteome. First, we performed LC-MS/MS on pooled SZ samples and pooled control samples for global proteomics analysis. Results revealed a high abundance of diverse proteins and peptides in eccrine sweat. Most of the proteins identified from sweat samples were found to be different than the most abundant proteins from serum, which indicates that eccrine sweat is not simply a plasma transudate, and may thereby be a source of unique disease-associated biomolecules. A second independent set of patient and control sweat samples were analyzed by LC-MS/MS and spectral counting to determine qualitative protein differential abundances between the control and disease groups. Differential abundances of selected proteins, initially determined by spectral counting, were verified by MRM-MS analyses. Seventeen proteins showed a differential abundance of approximately two-fold or greater between the SZ pooled sample and the control pooled sample. This study demonstrates the utility of LC-MS/MS and MRM-MS as a viable strategy for the discovery and verification of potential sweat protein disease biomarkers. PMID:22256890

  4. Evaluation of droplet digital PCR for quantification of residual leucocytes in red blood cell concentrates.

    PubMed

    Doescher, A; Loges, U; Petershofen, E K; Müller, T H

    2017-11-01

    Enumeration of residual white blood cells in leucoreduced blood components is essential part of quality control. Digital PCR has substantially facilitated quantitative PCR and was thus evaluated for measurements of leucocytes. Target for quantification of leucocytes by digital droplet PCR was the blood group gene RHCE. The SPEF1 gene was added as internal control for the entire assay starting with automated DNA extraction. The sensitivity of the method was determined by serial dilutions of standard samples. Quality control samples were analysed within 24 h, 7 days and 6 months after collection. Routine samples from leucodepleted red blood cell concentrates (n = 150) were evaluated in parallel by flow-cytometry (LeucoCount) and by digital PCR. Digital PCR reliably detected at least 0·4 leucocytes per assay. The mean difference between PCR and flow-cytometric results from 150 units was -0·01 (±1·0). DNA samples were stable for up to at least six months. PCR measurement of leucocytes in samples from plasma and platelet concentrates also provided valid results in a pilot study. Droplet digital PCR to enumerate leucocytes offers an alternative for quality control of leucoreduced blood products. Sensitivity, specificity and reproducibility are comparable to flow-cytometry. The option to collect samples over an extended period of time and the automatization introduce attractive features for routine quality control. © 2017 International Society of Blood Transfusion.

  5. Individual differences in components of impulsivity and effortful control moderate the relation between borderline personality disorder traits and emotion recognition in a sample of university students.

    PubMed

    Preti, Emanuele; Richetin, Juliette; Suttora, Chiara; Pisani, Alberto

    2016-04-30

    Dysfunctions in social cognition characterize personality disorders. However, mixed results emerged from literature on emotion processing. Borderline Personality Disorder (BPD) traits are either associated with enhanced emotion recognition, impairments, or equal functioning compared to controls. These apparent contradictions might result from the complexity of emotion recognition tasks used and from individual differences in impulsivity and effortful control. We conducted a study in a sample of undergraduate students (n=80), assessing BPD traits, using an emotion recognition task that requires the processing of only visual information or both visual and acoustic information. We also measured individual differences in impulsivity and effortful control. Results demonstrated the moderating role of some components of impulsivity and effortful control on the capability of BPD traits in predicting anger and happiness recognition. We organized the discussion around the interaction between different components of regulatory functioning and task complexity for a better understanding of emotion recognition in BPD samples. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. Groundwater-quality and quality-control data for two monitoring wells near Pavillion, Wyoming, April and May 2012

    USGS Publications Warehouse

    Wright, Peter R.; McMahon, Peter B.; Mueller, David K.; Clark, Melanie L.

    2012-01-01

    In June 2010, the U.S. Environmental Protection Agency installed two deep monitoring wells (MW01 and MW02) near Pavillion, Wyoming, to study groundwater quality. During April and May 2012, the U.S Geological Survey, in cooperation with the Wyoming Department of Environmental Quality, collected groundwater-quality data and quality-control data from monitoring well MW01 and, following well redevelopment, quality-control data for monitoring well MW02. Two groundwater-quality samples were collected from well MW01—one sample was collected after purging about 1.5 borehole volumes, and a second sample was collected after purging 3 borehole volumes. Both samples were collected and processed using methods designed to minimize atmospheric contamination or changes to water chemistry. Groundwater-quality samples were analyzed for field water-quality properties (water temperature, pH, specific conductance, dissolved oxygen, oxidation potential); inorganic constituents including naturally occurring radioactive compounds (radon, radium-226 and radium-228); organic constituents; dissolved gasses; stable isotopes of methane, water, and dissolved inorganic carbon; and environmental tracers (carbon-14, chlorofluorocarbons, sulfur hexafluoride, tritium, helium, neon, argon, krypton, xenon, and the ratio of helium-3 to helium-4). Quality-control sample results associated with well MW01 were evaluated to determine the extent to which environmental sample analytical results were affected by bias and to evaluate the variability inherent to sample collection and laboratory analyses. Field documentation, environmental data, and quality-control data for activities that occurred at the two monitoring wells during April and May 2012 are presented.

  7. Test and evaluation of Apollo 14 composite casting demonstration specimens and flight and control samples

    NASA Technical Reports Server (NTRS)

    Fabiniak, R. C.; Fabiniak, T. J.

    1971-01-01

    The results of experiments 1, 2, and 10 of the Apollo 14 composite casting demonstration are discussed. The purpose of the demonstration, with regard to samples 1 and 2, was to obtain preliminary data on the liquid phase sintering process in a weightless environment. With regard to sample 10, the purpose was to obtain preliminary information on how to achieve uniform dispersion of dense particles on a metal matrix by employing shaking modes or forces in the system when the metal matrix is molten. Results of the demonstrations were interpreted in a quantitative and qualitative manner. For experiment 1 it was found that the tungsten particles were redistributed more uniformly in the flight sample than in the control sample. Experiment 2 results indicate that complete melting may not have occured and thus a high degree of significance cannot be associated with the qualitative results relating to particle redistribution data. The particle-matrix system of experiment 10 was found to be nonwetting.

  8. Evaluation of single-nucleotide polymorphisms as internal controls in prenatal diagnosis of fetal blood groups.

    PubMed

    Doescher, Andrea; Petershofen, Eduard K; Wagner, Franz F; Schunter, Markus; Müller, Thomas H

    2013-02-01

    Determination of fetal blood groups in maternal plasma samples critically depends on adequate amplification of fetal DNA. We evaluated the routine inclusion of 52 single-nucleotide polymorphisms (SNPs) as internal reference in our polymerase chain reaction (PCR) settings to obtain a positive internal control for fetal DNA. DNA from 223 plasma samples of pregnant women was screened for RHD Exons 3, 4, 5, and 7 in a multiplex PCR including 52 SNPs divided into four primer pools. Amplicons were analyzed by single-base extension and the GeneScan method in a genetic analyzer. Results of D screening were compared to standard RHD genotyping of amniotic fluid or real-time PCR of fetal DNA from maternal plasma. The vast majority of all samples (97.8%) demonstrated differences in maternal and fetal SNP patterns when tested with four primer pools. These differences were not observed in less than 2.2% of the samples most probably due to an extraction failure for adequate amounts of fetal DNA. Comparison of the fetal genotypes with independent results did not reveal a single false-negative case among samples (n = 42) with positive internal control and negative fetal RHD typing. Coamplification of 52 SNPs with RHD-specific sequences for fetal blood group determination introduces a valid positive control for the amplification of fetal DNA to avoid false-negative results. This new approach does not require a paternal blood sample. It may also be applicable to other assays for fetal genotyping in maternal blood samples. © 2012 American Association of Blood Banks.

  9. Replication and meta-analysis of TMEM132D gene variants in panic disorder

    PubMed Central

    Erhardt, A; Akula, N; Schumacher, J; Czamara, D; Karbalai, N; Müller-Myhsok, B; Mors, O; Borglum, A; Kristensen, A S; Woldbye, D P D; Koefoed, P; Eriksson, E; Maron, E; Metspalu, A; Nurnberger, J; Philibert, R A; Kennedy, J; Domschke, K; Reif, A; Deckert, J; Otowa, T; Kawamura, Y; Kaiya, H; Okazaki, Y; Tanii, H; Tokunaga, K; Sasaki, T; Ioannidis, J P A; McMahon, F J; Binder, E B

    2012-01-01

    A recent genome-wide association study in patients with panic disorder (PD) identified a risk haplotype consisting of two single-nucleotide polymorphisms (SNPs) (rs7309727 and rs11060369) located in intron 3 of TMEM132D to be associated with PD in three independent samples. Now we report a subsequent confirmation study using five additional PD case–control samples (n=1670 cases and n=2266 controls) assembled as part of the Panic Disorder International Consortium (PanIC) study for a total of 2678 cases and 3262 controls in the analysis. In the new independent samples of European ancestry (EA), the association of rs7309727 and the risk haplotype rs7309727–rs11060369 was, indeed, replicated, with the strongest signal coming from patients with primary PD, that is, patients without major psychiatric comorbidities (n=1038 cases and n=2411 controls). This finding was paralleled by the results of the meta-analysis across all samples, in which the risk haplotype and rs7309727 reached P-levels of P=1.4e−8 and P=1.1e−8, respectively, when restricting the samples to individuals of EA with primary PD. In the Japanese sample no associations with PD could be found. The present results support the initial finding that TMEM132D gene contributes to genetic susceptibility for PD in individuals of EA. Our results also indicate that patient ascertainment and genetic background could be important sources of heterogeneity modifying this association signal in different populations. PMID:22948381

  10. An Improved Model Predictive Current Controller of Switched Reluctance Machines Using Time-Multiplexed Current Sensor

    PubMed Central

    Li, Bingchu; Ling, Xiao; Huang, Yixiang; Gong, Liang; Liu, Chengliang

    2017-01-01

    This paper presents a fixed-switching-frequency model predictive current controller using multiplexed current sensor for switched reluctance machine (SRM) drives. The converter was modified to distinguish currents from simultaneously excited phases during the sampling period. The only current sensor installed in the converter was time division multiplexing for phase current sampling. During the commutation stage, the control steps of adjacent phases were shifted so that sampling time was staggered. The maximum and minimum duty ratio of pulse width modulation (PWM) was limited to keep enough sampling time for analog-to-digital (A/D) conversion. Current sensor multiplexing was realized without complex adjustment of either driver circuit nor control algorithms, while it helps to reduce the cost and errors introduced in current sampling due to inconsistency between sensors. The proposed controller is validated by both simulation and experimental results with a 1.5 kW three-phase 12/8 SRM. Satisfied current sampling is received with little difference compared with independent phase current sensors for each phase. The proposed controller tracks the reference current profile as accurately as the model predictive current controller with independent phase current sensors, while having minor tracking errors compared with a hysteresis current controller. PMID:28513554

  11. Abnormalities in early markers of muscle involvement support a delay in myogenesis in spinal muscular atrophy.

    PubMed

    Martínez-Hernández, Rebeca; Bernal, Sara; Alias, Laura; Tizzano, Eduardo F

    2014-06-01

    Spinal muscular atrophy (SMA) is characterized by loss of motor neurons in the spinal cord that results in muscle denervation and profound weakness in affected patients. We sought evidence for primary muscle involvement in the disease during human development by analyzing the expression of several muscle cytoskeletal components (i.e. slow, fast, and developmental myosin, desmin, and vimentin) in fetal or postnatal skeletal muscle samples from 5 SMA cases and 6 controls. At 14 weeks' gestation, SMA samples had higher percentages of myotubes expressing fast myosin and lower percentages of myotubes expressing slow myosin versus control samples. Desmin and vimentin were highly expressed at prenatal stages without notable differences between control and SMA samples, although both proteins showed persistent immunostaining in atrophic fibers in postnatal SMA samples. We also studied the expression of Pax7-positive nuclei as a marker of satellite cells and found no differences between control and SMA prenatal samples. There was, however, a significant increase in satellite cells in postnatal atrophic SMA fibers, suggesting an abnormal myogenic process. Together, these results support the hypothesis of a delay in muscle maturation as one of the primary pathologic components of SMA. Furthermore, myosins and Pax7 may be useful research markers of muscle involvement in this disease.

  12. Chronic Rhinosinusitis: Potential Role of Microbial Dysbiosis and Recommendations for Sampling Sites

    PubMed Central

    Copeland, Elizabeth; Leonard, Katherine; Carney, Richard; Kong, Justin; Forer, Martin; Naidoo, Yuresh; Oliver, Brian G. G.; Seymour, Justin R.; Woodcock, Stephen; Burke, Catherine M.; Stow, Nicholas W.

    2018-01-01

    Chronic rhinosinusitis (CRS) is an inflammatory condition that affects up to 12% of the human population in developed countries. Previous studies examining the potential role of the sinus bacterial microbiota within CRS infections have found inconsistent results, possibly because of inconsistencies in sampling strategies. The aim of this study was to determine whether the sinus microbiome is altered in CRS and additionally if the middle meatus is a suitable representative site for sampling the sinus microbiome. Swab samples were collected from 12 healthy controls and 21 CRS patients, including all eight sinuses for CRS patients and between one and five sinuses for control subjects. The left and right middle meatus and nostril swabs were also collected. Significant differences in the sinus microbiomes between CRS and control samples were revealed using high-throughput 16S rRNA gene sequencing. The genus Escherichia was over-represented in CRS sinuses, and associations between control patients and Corynebacterium and Dolosigranulum were also identified. Comparisons of the middle meatuses between groups did not reflect these differences, and the abundance of the genus Escherichia was significantly lower at this location. Additionally, intra-patient variation was lower between sinuses than between sinus and middle meatus, which together with the above results suggests that the middle meatus is not an effective representative sampling site. PMID:29541629

  13. Irregular analytical errors in diagnostic testing - a novel concept.

    PubMed

    Vogeser, Michael; Seger, Christoph

    2018-02-23

    In laboratory medicine, routine periodic analyses for internal and external quality control measurements interpreted by statistical methods are mandatory for batch clearance. Data analysis of these process-oriented measurements allows for insight into random analytical variation and systematic calibration bias over time. However, in such a setting, any individual sample is not under individual quality control. The quality control measurements act only at the batch level. Quantitative or qualitative data derived for many effects and interferences associated with an individual diagnostic sample can compromise any analyte. It is obvious that a process for a quality-control-sample-based approach of quality assurance is not sensitive to such errors. To address the potential causes and nature of such analytical interference in individual samples more systematically, we suggest the introduction of a new term called the irregular (individual) analytical error. Practically, this term can be applied in any analytical assay that is traceable to a reference measurement system. For an individual sample an irregular analytical error is defined as an inaccuracy (which is the deviation from a reference measurement procedure result) of a test result that is so high it cannot be explained by measurement uncertainty of the utilized routine assay operating within the accepted limitations of the associated process quality control measurements. The deviation can be defined as the linear combination of the process measurement uncertainty and the method bias for the reference measurement system. Such errors should be coined irregular analytical errors of the individual sample. The measurement result is compromised either by an irregular effect associated with the individual composition (matrix) of the sample or an individual single sample associated processing error in the analytical process. Currently, the availability of reference measurement procedures is still highly limited, but LC-isotope-dilution mass spectrometry methods are increasingly used for pre-market validation of routine diagnostic assays (these tests also involve substantial sets of clinical validation samples). Based on this definition/terminology, we list recognized causes of irregular analytical error as a risk catalog for clinical chemistry in this article. These issues include reproducible individual analytical errors (e.g. caused by anti-reagent antibodies) and non-reproducible, sporadic errors (e.g. errors due to incorrect pipetting volume due to air bubbles in a sample), which can both lead to inaccurate results and risks for patients.

  14. An integrated bioanalytical method development and validation approach: case studies.

    PubMed

    Xue, Y-J; Melo, Brian; Vallejo, Martha; Zhao, Yuwen; Tang, Lina; Chen, Yuan-Shek; Keller, Karin M

    2012-10-01

    We proposed an integrated bioanalytical method development and validation approach: (1) method screening based on analyte's physicochemical properties and metabolism information to determine the most appropriate extraction/analysis conditions; (2) preliminary stability evaluation using both quality control and incurred samples to establish sample collection, storage and processing conditions; (3) mock validation to examine method accuracy and precision and incurred sample reproducibility; and (4) method validation to confirm the results obtained during method development. This integrated approach was applied to the determination of compound I in rat plasma and compound II in rat and dog plasma. The effectiveness of the approach was demonstrated by the superior quality of three method validations: (1) a zero run failure rate; (2) >93% of quality control results within 10% of nominal values; and (3) 99% incurred sample within 9.2% of the original values. In addition, rat and dog plasma methods for compound II were successfully applied to analyze more than 900 plasma samples obtained from Investigational New Drug (IND) toxicology studies in rats and dogs with near perfect results: (1) a zero run failure rate; (2) excellent accuracy and precision for standards and quality controls; and (3) 98% incurred samples within 15% of the original values. Copyright © 2011 John Wiley & Sons, Ltd.

  15. Level 1 environmental assessment performance evaluation. Final report jun 77-oct 78

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Estes, E.D.; Smith, F.; Wagoner, D.E.

    1979-02-01

    The report gives results of a two-phased evaluation of Level 1 environmental assessment procedures. Results from Phase I, a field evaluation of the Source Assessment Sampling System (SASS), showed that the SASS train performed well within the desired factor of 3 Level 1 accuracy limit. Three sample runs were made with two SASS trains sampling simultaneously and from approximately the same sampling point in a horizontal duct. A Method-5 train was used to estimate the 'true' particulate loading. The sampling systems were upstream of the control devices to ensure collection of sufficient material for comparison of total particulate, particle sizemore » distribution, organic classes, and trace elements. Phase II consisted of providing each of three organizations with three types of control samples to challenge the spectrum of Level 1 analytical procedures: an artificial sample in methylene chloride, an artificial sample on a flyash matrix, and a real sample composed of the combined XAD-2 resin extracts from all Phase I runs. Phase II results showed that when the Level 1 analytical procedures are carefully applied, data of acceptable accuracy is obtained. Estimates of intralaboratory and interlaboratory precision are made.« less

  16. Mechanical Properties of Lightweight Concrete Using Recycled Cement-Sand Brick as Coarse Aggregates Replacement

    NASA Astrophysics Data System (ADS)

    Joohari, Ilya; Farhani Ishak, Nor; Amin, Norliyati Mohd

    2018-03-01

    This paper presents the result of replacing natural course aggregate with recycled cement-sand brick (CSB) towards the mechanical properties of concrete. Natural aggregates were used in this study as a control sample to compare with recycled coarse aggregates. This study was also carried to determine the optimum proportion of coarse aggregates replacement to produce lightweight concrete. Besides, this study was conducted to observe the crack and its behaviour development during the mechanical testing. Through this study, four types of concrete mixed were prepared, which were the control sample, 25%, 50% and 75% replacement of CSB. The test conducted to determine the effectiveness of recycled CSB as coarse aggregates replacement in this study were slump test, density measurement, compression test, and flexural test and. The strength of concrete was tested at 7 days and 28 days of curing. From the results obtained, the optimum proportion which produced the highest strength is 25% replacement of recycled CSB. The compressive and flexural strength has decreased by 10%-12% and 4%-34% respectively compared to the control sample. The presence of recycled coarse aggregates in sample has decreased the density of concrete by 0.8%-3% compared to the control sample.

  17. [Analysis on 2011 quality control results on aerobic plate count of microbiology laboratories in China].

    PubMed

    Han, Haihong; Li, Ning; Li, Yepeng; Fu, Ping; Yu, Dongmin; Li Zhigang; Du, Chunming; Guo, Yunchang

    2015-01-01

    To test the aerobic plate count examining capability of microbiology laboratories, to ensure the accuracy and comparability of quantitative bacteria examination results, and to improve the quality of monitoring. The 4 different concentration aerobic plate count piece samples were prepared and noted as I, II, III and IV. After homogeneity and stability tests, the samples were delivered to monitoring institutions. The results of I, II, III samples were logarithmic transformed, and evaluated with Z-score method using the robust average and standard deviation. The results of IV samples were evaluated as "satisfactory" when reported as < 10 CFU/piece or as "not satisfactory" otherwise. Pearson χ2 test was used to analyze the ratio results. 309 monitoring institutions, which was 99.04% of the total number, reported their results. 271 institutions reported a satisfactory result, and the satisfactory rate was 87.70%. There was no statistical difference in satisfactory rates of I, II and III samples which were 81.52%, 88.30% and 91.40% respectively. The satisfactory rate of IV samples was 93.33%. There was no statistical difference in satisfactory rates between provincial and municipal CDC. The quality control program has provided scientific data that the aerobic plate count capability of the laboratories meets the requirements of monitoring tasks.

  18. A novel approach to periodic event-triggered control: Design and application to the inverted pendulum.

    PubMed

    Aranda-Escolástico, Ernesto; Guinaldo, María; Gordillo, Francisco; Dormido, Sebastián

    2016-11-01

    In this paper, periodic event-triggered controllers are proposed for the rotary inverted pendulum. The control strategy is divided in two steps: swing-up and stabilization. In both cases, the system is sampled periodically but the control actions are only computed at certain instances of time (based on events), which are a subset of the sampling times. For the stabilization control, the asymptotic stability is guaranteed applying the Lyapunov-Razumikhin theorem for systems with delays. This result is applicable to general linear systems and not only to the inverted pendulum. For the swing-up control, a trigger function is provided from the derivative of the Lyapunov function for the swing-up control law. Experimental results show a significant improvement with respect to periodic control in the number of control actions. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  19. Sampled-data design for sliding mode control based on various robust specifications in open quantum system

    NASA Astrophysics Data System (ADS)

    Ji, Yinghua; Ju-Ju, Hu; Jian-Hua, Huang; Qiang, Ke

    Due to the influence of decoherence, the quantum state probably evolves from the initial pure state to the mixed state, resulting in loss of fidelity, coherence and purity, which is deteriorating for quantum information transmission. Thus, in quantum engineering, quantum control should not only realize the transfer and track of quantum states through manipulation of the external electromagnetic field but also enhance the robustness against decoherence. In this paper, we aim to design a control law to steer the system into the sliding mode domain and maintain it in that domain when bounded uncertainties exist in the system Hamiltonian. We first define the required control performance by fidelity, degree of coherence and purity in terms of the uncertainty of the Hamiltonian in Markovian open quantum system. By characterizing the required robustness using a sliding mode domain, a sampled-data design method is introduced for decoherence control in the quantum system. Furthermore, utilizing the sampled data, a control scheme has been designed on the basis of sliding mode control, and the choice of sampling operator and driving of quantum state during the sampling by the Lyapunov control method are discussed.

  20. Metagenomic Investigation of Plasma in Individuals with ME/CFS Highlights the Importance of Technical Controls to Elucidate Contamination and Batch Effects.

    PubMed

    Miller, Ruth R; Uyaguari-Diaz, Miguel; McCabe, Mark N; Montoya, Vincent; Gardy, Jennifer L; Parker, Shoshana; Steiner, Theodore; Hsiao, William; Nesbitt, Matthew J; Tang, Patrick; Patrick, David M

    2016-01-01

    Myalgic Encephalomyelitis/Chronic Fatigue Syndrome (ME/CFS) is a debilitating disease causing indefinite fatigue. ME/CFS has long been hypothesised to have an infectious cause; however, no specific infectious agent has been identified. We used metagenomics to analyse the RNA from plasma samples from 25 individuals with ME/CFS and compare their microbial content to technical controls as well as three control groups: individuals with alternatively diagnosed chronic Lyme syndrome (N = 13), systemic lupus erythematosus (N = 11), and healthy controls (N = 25). We found that the majority of sequencing reads were removed during host subtraction, thus there was very low microbial RNA content in the plasma. The effects of sample batching and contamination during sample processing proved to outweigh the effects of study group on microbial RNA content, as the few differences in bacterial or viral RNA abundance we did observe between study groups were most likely caused by contamination and batch effects. Our results highlight the importance of including negative controls in all metagenomic analyses, since there was considerable overlap between bacterial content identified in study samples and control samples. For example, Proteobacteria, Firmicutes, Actinobacteria, and Bacteriodes were found in both study samples and plasma-free negative controls. Many of the taxonomic groups we saw in our plasma-free negative control samples have previously been associated with diseases, including ME/CFS, demonstrating how incorrect conclusions may arise if controls are not used and batch effects not accounted for.

  1. Preliminary post-tsunami water quality survey in Phang-Nga province, southern Thailand.

    PubMed

    Tharnpoophasiam, Prapin; Suthisarnsuntorn, Usanee; Worakhunpiset, Suwalee; Charoenjai, Prasasana; Tunyong, Witawat; Phrom-In, Suvannee; Chattanadee, Siriporn

    2006-01-01

    This preliminary water quality survey was performed eight weeks after the tsunami hit Phang-Nga Province on 26 December 2004. Water samples collected from the affected area, 10 km parallel to the seaside, were compared with water samples from the control area approximately 4 km from the seaside, which the tsunami waves could not reach. These samples included 18 surface-water samples, 37 well-water samples, and 8 drinking-water samples, which were examined for microbiology and physical-chemical properties. The microbiological examinations focused on enteric bacteria, which were isolated by culture method, while physical-chemical properties comprised on-site testing for pH, salinity, dissolved oxygen (DO), conductivity and total dissolved solids (TDS) by portable electrochemical meter (Sens Ion 156). The results of the microbiological examinations showed that water samples in the affected areas were more contaminated with enteric bacteria than the control area: 45.4% of surface-water samples in the affected area, and 40.0% in the control; 19.0% of well-water samples in the affected area, and 7.7% in the control. All eight drinking-water samples were clear of enteric bacteria. Tests for physical-chemical properties showed that the salinity, pH, conductivity, and TDS of surface-water samples from the affected area were significantly higher than the control. The salinity, conductivity, and TDS of the well-water samples from the affected areas were also significantly greater than those from the control area. The surface and well water in the tsunami-affected area have been changed greatly and need improvement.

  2. Can the Roche hemolysis index be used for automated determination of cell-free hemoglobin? A comparison to photometric assays.

    PubMed

    Petrova, Darinka Todorova; Cocisiu, Gabriela Ariadna; Eberle, Christoph; Rhode, Karl-Heinz; Brandhorst, Gunnar; Walson, Philip D; Oellerich, Michael

    2013-09-01

    The aim of this study was to develop a novel method for automated quantification of cell-free hemoglobin (fHb) based on the HI (Roche Diagnostics). The novel fHb method based on the HI was correlated with fHb measured using the triple wavelength methods of both Harboe [fHb, g/L = (0.915 * HI + 2.634)/100] and Fairbanks et al. [fHb, g/L = (0.917 * HI + 2.131)/100]. fHb concentrations were estimated from the HI using the Roche Modular automated platform in self-made and commercially available quality controls, as well as samples from a proficiency testing scheme (INSTAND). The fHb using Roche automated HI results were then compared to results obtained using the traditional spectrophotometric assays for one hundred plasma samples with varying degrees of hemolysis, lipemia and/or bilirubinemia. The novel method using automated HI quantification on the Roche Modular clinical chemistry platform correlated well with results using the classical methods in the 100 patient samples (Harboe: r = 0.9284; Fairbanks et al.: r = 0.9689) and recovery was good for self-made controls. However, commercially available quality controls showed poor recovery due to an unidentified matrix problem. The novel method produced reliable determination of fHb in samples without interferences. However, poor recovery using commercially available fHb quality control samples currently greatly limits its usefulness. © 2013.

  3. Improved synchronization criteria for time-delayed chaotic Lur'e systems using sampled-data control

    NASA Astrophysics Data System (ADS)

    Duan, Wenyong; Li, Yan; Fu, Xiaorong; Du, Baozhu

    2017-02-01

    This paper is concerned with the synchronization for a class of time-delayed chaotic Lur’e systems using sampled-data control. Both of time-varying and time-invariant delays are considered. New criteria are proposed in terms of linear matrix inequalities (LMIs) by employing a modified LKF combined with the delay-fraction theory and some novel terms. The criteria are less conservative than some previous ones and a longer sampling period is achieved under the new results. Furthermore, the derived conditions are employed to design a sampled-data controller. The desired controller gain matrix can be obtained by means of the LMI approach. Finally, a numerical examples and simulations on Chua’s circuit is presented to show the effectiveness of the proposed approach.

  4. Effect of denture cleansing agents on tensile and shear bond strengths of soft liners to acrylic denture base.

    PubMed

    Mahboub, Farhang; Salehsaber, Fariba; Parnia, Fereydoon; Gharekhani, Vahedeh; Kananizadeh, Yousef; Taghizadeh, Mahsa

    2017-01-01

    Background. The aim of the present study was to evaluate the effect of Corega and 2.5% sodium hypochlorite cleansing agents on the shear and tensile bond strengths of GC soft liner to denture base. Methods. A total of 144 samples (72 samples for tensile and 72 for shear bond strength evaluations) were prepared. The samples in each group were subdivided into three subgroups in terms of the cleansing agent used (2.5% sodium hypochlorite, Corega and distilled water [control group]). All the samples were stored in distilled water, during which each sample was immersed for 15 minutes daily in sodium hypochlorite or Corega solutions. After 20 days the tensile and shear bond strengths were determined using a universal testing machine. In addition, a stereomicroscope was used to evaluate fracture modes. Data were analyzed with one-way ANOVA, using SPSS 16. Results. The results of post hoc Tukey tests showed significant differences in the mean tensile and shear bond strength values between the sodium hypochlorite group with Corega and control groups (P=0.001 for comparison of tensile bond strengths between the sodium hypochlorite and control groups, and P<0.001 for the comparison of tensile bond strengths between the sodium hypochlorite and Corega groups and the shear bond strengths between the sodium hypochlorite and Corega groups, and sodium hypochlorite and control groups).The majority of failures were cohesive in the control and Corega groups and cohesive/adhesive in the sodium hypochlorite group. Conclusion. Immersion of soft liners in Corega will result in longevity of soft liners compared to immersion in sodium hypochlorite solution and sodium hypochlorite solution significantly decreased the tensile and shear bond strengths compared to the control and Corega groups.

  5. Effect of denture cleansing agents on tensile and shear bond strengths of soft liners to acrylic denture base

    PubMed Central

    Mahboub, Farhang; Salehsaber, Fariba; Parnia, Fereydoon; Gharekhani, Vahedeh; Kananizadeh, Yousef; Taghizadeh, Mahsa

    2017-01-01

    Background. The aim of the present study was to evaluate the effect of Corega and 2.5% sodium hypochlorite cleansing agents on the shear and tensile bond strengths of GC soft liner to denture base. Methods. A total of 144 samples (72 samples for tensile and 72 for shear bond strength evaluations) were prepared. The samples in each group were subdivided into three subgroups in terms of the cleansing agent used (2.5% sodium hypochlorite, Corega and distilled water [control group]). All the samples were stored in distilled water, during which each sample was immersed for 15 minutes daily in sodium hypochlorite or Corega solutions. After 20 days the tensile and shear bond strengths were determined using a universal testing machine. In addition, a stereomicroscope was used to evaluate fracture modes. Data were analyzed with one-way ANOVA, using SPSS 16. Results. The results of post hoc Tukey tests showed significant differences in the mean tensile and shear bond strength values between the sodium hypochlorite group with Corega and control groups (P=0.001 for comparison of tensile bond strengths between the sodium hypochlorite and control groups, and P<0.001 for the comparison of tensile bond strengths between the sodium hypochlorite and Corega groups and the shear bond strengths between the sodium hypochlorite and Corega groups, and sodium hypochlorite and control groups).The majority of failures were cohesive in the control and Corega groups and cohesive/adhesive in the sodium hypochlorite group. Conclusion. Immersion of soft liners in Corega will result in longevity of soft liners compared to immersion in sodium hypochlorite solution and sodium hypochlorite solution significantly decreased the tensile and shear bond strengths compared to the control and Corega groups. PMID:29184635

  6. Optimizing the Combination of Smoking and Boiling on Quality of Korean Traditional Boiled Loin (M. longissimus dorsi)

    PubMed Central

    Choi, Yun-Sang; Kim, Hyun-Wook; Kim, Young-Boong; Kim, Cheon-Jei

    2015-01-01

    The combined effects of smoking and boiling on the proximate composition, technological quality traits, shear force, and sensory characteristics of the Korean traditional boiled loin were studied. Cooking loss, processing loss, and shear force were lower in the smoked/boiled samples than those in the control (without smoking treatment) (p<0.05). The results showed that the boiled loin samples between the control and treatment did not differ significantly in protein, fat, or ash contents, or pH values (p>0.05). The treated samples had higher score for overall acceptability than the control (p<0.05). Thus, these results show that the Korean traditional boiled loin treated with smoking for 60 min before boiling had improved physicochemical properties and sensory characteristics. PMID:26761822

  7. Quality Control for Ambient Sampling of PCDD/PCDF from Open Combustion Sources

    EPA Science Inventory

    Both long duration (> 6 h) and high temperature (up to 139o C) sampling efforts were conducted using ambient air sampling methods to determine if either high volume throughput or higher than ambient sampling temperatures resulted in loss of target polychlorinated dibenzodioxins/d...

  8. The benefits of soft sensor and multi-rate control for the implementation of Wireless Networked Control Systems.

    PubMed

    Mansano, Raul K; Godoy, Eduardo P; Porto, Arthur J V

    2014-12-18

    Recent advances in wireless networking technology and the proliferation of industrial wireless sensors have led to an increasing interest in using wireless networks for closed loop control. The main advantages of Wireless Networked Control Systems (WNCSs) are the reconfigurability, easy commissioning and the possibility of installation in places where cabling is impossible. Despite these advantages, there are two main problems which must be considered for practical implementations of WNCSs. One problem is the sampling period constraint of industrial wireless sensors. This problem is related to the energy cost of the wireless transmission, since the power supply is limited, which precludes the use of these sensors in several closed-loop controls. The other technological concern in WNCS is the energy efficiency of the devices. As the sensors are powered by batteries, the lowest possible consumption is required to extend battery lifetime. As a result, there is a compromise between the sensor sampling period, the sensor battery lifetime and the required control performance for the WNCS. This paper develops a model-based soft sensor to overcome these problems and enable practical implementations of WNCSs. The goal of the soft sensor is generating virtual data allowing an actuation on the process faster than the maximum sampling period available for the wireless sensor. Experimental results have shown the soft sensor is a solution to the sampling period constraint problem of wireless sensors in control applications, enabling the application of industrial wireless sensors in WNCSs. Additionally, our results demonstrated the soft sensor potential for implementing energy efficient WNCS through the battery saving of industrial wireless sensors.

  9. Rock sampling. [method for controlling particle size distribution

    NASA Technical Reports Server (NTRS)

    Blum, P. (Inventor)

    1971-01-01

    A method for sampling rock and other brittle materials and for controlling resultant particle sizes is described. The method involves cutting grooves in the rock surface to provide a grouping of parallel ridges and subsequently machining the ridges to provide a powder specimen. The machining step may comprise milling, drilling, lathe cutting or the like; but a planing step is advantageous. Control of the particle size distribution is effected primarily by changing the height and width of these ridges. This control exceeds that obtainable by conventional grinding.

  10. Using ancestry matching to combine family-based and unrelated samples for genome-wide association studies‡

    PubMed Central

    Crossett, Andrew; Kent, Brian P.; Klei, Lambertus; Ringquist, Steven; Trucco, Massimo; Roeder, Kathryn; Devlin, Bernie

    2015-01-01

    We propose a method to analyze family-based samples together with unrelated cases and controls. The method builds on the idea of matched case–control analysis using conditional logistic regression (CLR). For each trio within the family, a case (the proband) and matched pseudo-controls are constructed, based upon the transmitted and untransmitted alleles. Unrelated controls, matched by genetic ancestry, supplement the sample of pseudo-controls; likewise unrelated cases are also paired with genetically matched controls. Within each matched stratum, the case genotype is contrasted with control pseudo-control genotypes via CLR, using a method we call matched-CLR (mCLR). Eigenanalysis of numerous SNP genotypes provides a tool for mapping genetic ancestry. The result of such an analysis can be thought of as a multidimensional map, or eigenmap, in which the relative genetic similarities and differences amongst individuals is encoded in the map. Once constructed, new individuals can be projected onto the ancestry map based on their genotypes. Successful differentiation of individuals of distinct ancestry depends on having a diverse, yet representative sample from which to construct the ancestry map. Once samples are well-matched, mCLR yields comparable power to competing methods while ensuring excellent control over Type I error. PMID:20862653

  11. Environmental Validation of Legionella Control in a VHA Facility Water System.

    PubMed

    Jinadatha, Chetan; Stock, Eileen M; Miller, Steve E; McCoy, William F

    2018-03-01

    OBJECTIVES We conducted this study to determine what sample volume, concentration, and limit of detection (LOD) are adequate for environmental validation of Legionella control. We also sought to determine whether time required to obtain culture results can be reduced compared to spread-plate culture method. We also assessed whether polymerase chain reaction (PCR) and in-field total heterotrophic aerobic bacteria (THAB) counts are reliable indicators of Legionella in water samples from buildings. DESIGN Comparative Legionella screening and diagnostics study for environmental validation of a healthcare building water system. SETTING Veterans Health Administration (VHA) facility water system in central Texas. METHODS We analyzed 50 water samples (26 hot, 24 cold) from 40 sinks and 10 showers using spread-plate cultures (International Standards Organization [ISO] 11731) on samples shipped overnight to the analytical lab. In-field, on-site cultures were obtained using the PVT (Phigenics Validation Test) culture dipslide-format sampler. A PCR assay for genus-level Legionella was performed on every sample. RESULTS No practical differences regardless of sample volume filtered were observed. Larger sample volumes yielded more detections of Legionella. No statistically significant differences at the 1 colony-forming unit (CFU)/mL or 10 CFU/mL LOD were observed. Approximately 75% less time was required when cultures were started in the field. The PCR results provided an early warning, which was confirmed by spread-plate cultures. The THAB results did not correlate with Legionella status. CONCLUSIONS For environmental validation at this facility, we confirmed that (1) 100 mL sample volumes were adequate, (2) 10× concentrations were adequate, (3) 10 CFU/mL LOD was adequate, (4) in-field cultures reliably reduced time to get results by 75%, (5) PCR provided a reliable early warning, and (6) THAB was not predictive of Legionella results. Infect Control Hosp Epidemiol 2018;39:259-266.

  12. Enhanced atomic gas fractions in recently merged galaxies: quenching is not a result of post-merger gas exhaustion.

    NASA Astrophysics Data System (ADS)

    Ellison, Sara L.; Catinella, Barbara; Cortese, Luca

    2018-05-01

    We present a detailed assessment of the global atomic hydrogen gas fraction (fgas=log[MHI/M⋆]) in a sample of post-merger galaxies identified in the Sloan Digital Sky Survey (SDSS). Archival H I measurements of 47 targets are combined with new Arecibo observations of a further 51 galaxies. The stellar mass range of the post-merger sample, our observing strategy, detection thresholds and data analysis procedures replicate those of the extended GALEX Arecibo SDSS Survey (xGASS) which can therefore be used as a control sample. Our principal results are: 1) The post-merger sample shows a ˜ 50 per cent higher H I detection fraction compared with xGASS; 2) Accounting for non-detections, the median atomic gas fraction of the post-merger sample is larger than the control sample by 0.3 - 0.6 dex; 3) The median atomic gas fraction enhancement (Δfgas), computed on a galaxy-by-galaxy basis at fixed stellar mass, is 0.51 dex. Our results demonstrate that recently merged galaxies are typically a factor of ˜ 3 more H I rich than control galaxies of the same M⋆. If the control sample is additionally matched in star formation rate, the median H I excess is reduced to Δfgas = 0.2 dex, showing that the enhanced atomic gas fractions in post-mergers are not purely a reflection of changes in star formation activity. We conclude that merger-induced starbursts and outflows do not lead to prompt quenching via exhaustion/expulsion of the galactic gas reservoirs. Instead, we propose that if star formation ceases after a merger, it is more likely due to an enhanced turbulence which renders the galaxy unable to effectively form new stars.

  13. Effects of xanthan, guar, carrageenan and locust bean gum addition on physical, chemical and sensory properties of meatballs.

    PubMed

    Demirci, Zeynep Ozben; Yılmaz, Ismail; Demirci, Ahmet Şukru

    2014-05-01

    This study evaluated the effects of xanthan gum, guar gum, carrageenan and locust bean gum on physical, chemical and sensory properties of meatballs. Meatball samples were produced with three different formulations including of 0.5, 1, and 1.5% each gum addition and gum added samples were compared with the control meatballs. Physical and chemical analyses were carried out on raw and cooked samples separately. Moisture contents of raw samples decreased by addition of gums. There were significant decreases (p < 0.05) in moisture and fat contents of raw and cooked meatball samples formulated with gum when compared with control. Ash contents and texture values increased with gum addition to meatballs. Meatball redness decreased with more gum addition in raw and cooked meatball samples, which means that addition of gums resulted in a lighter-coloured product. According to sensory analysis results, locust bean gum added (1%) samples were much preferred by the panelists.

  14. Statistical transformation and the interpretation of inpatient glucose control data from the intensive care unit.

    PubMed

    Saulnier, George E; Castro, Janna C; Cook, Curtiss B

    2014-05-01

    Glucose control can be problematic in critically ill patients. We evaluated the impact of statistical transformation on interpretation of intensive care unit inpatient glucose control data. Point-of-care blood glucose (POC-BG) data derived from patients in the intensive care unit for 2011 was obtained. Box-Cox transformation of POC-BG measurements was performed, and distribution of data was determined before and after transformation. Different data subsets were used to establish statistical upper and lower control limits. Exponentially weighted moving average (EWMA) control charts constructed from April, October, and November data determined whether out-of-control events could be identified differently in transformed versus nontransformed data. A total of 8679 POC-BG values were analyzed. POC-BG distributions in nontransformed data were skewed but approached normality after transformation. EWMA control charts revealed differences in projected detection of out-of-control events. In April, an out-of-control process resulting in the lower control limit being exceeded was identified at sample 116 in nontransformed data but not in transformed data. October transformed data detected an out-of-control process exceeding the upper control limit at sample 27 that was not detected in nontransformed data. Nontransformed November results remained in control, but transformation identified an out-of-control event less than 10 samples into the observation period. Using statistical methods to assess population-based glucose control in the intensive care unit could alter conclusions about the effectiveness of care processes for managing hyperglycemia. Further study is required to determine whether transformed versus nontransformed data change clinical decisions about the interpretation of care or intervention results. © 2014 Diabetes Technology Society.

  15. Statistical Transformation and the Interpretation of Inpatient Glucose Control Data From the Intensive Care Unit

    PubMed Central

    Saulnier, George E.; Castro, Janna C.

    2014-01-01

    Glucose control can be problematic in critically ill patients. We evaluated the impact of statistical transformation on interpretation of intensive care unit inpatient glucose control data. Point-of-care blood glucose (POC-BG) data derived from patients in the intensive care unit for 2011 was obtained. Box–Cox transformation of POC-BG measurements was performed, and distribution of data was determined before and after transformation. Different data subsets were used to establish statistical upper and lower control limits. Exponentially weighted moving average (EWMA) control charts constructed from April, October, and November data determined whether out-of-control events could be identified differently in transformed versus nontransformed data. A total of 8679 POC-BG values were analyzed. POC-BG distributions in nontransformed data were skewed but approached normality after transformation. EWMA control charts revealed differences in projected detection of out-of-control events. In April, an out-of-control process resulting in the lower control limit being exceeded was identified at sample 116 in nontransformed data but not in transformed data. October transformed data detected an out-of-control process exceeding the upper control limit at sample 27 that was not detected in nontransformed data. Nontransformed November results remained in control, but transformation identified an out-of-control event less than 10 samples into the observation period. Using statistical methods to assess population-based glucose control in the intensive care unit could alter conclusions about the effectiveness of care processes for managing hyperglycemia. Further study is required to determine whether transformed versus nontransformed data change clinical decisions about the interpretation of care or intervention results. PMID:24876620

  16. The resident microflora of voided midstream urine of healthy controls: standard versus expanded urine culture protocols.

    PubMed

    Coorevits, L; Heytens, S; Boelens, J; Claeys, G

    2017-04-01

    The workup and interpretation of urine cultures is not always clear-cut, especially for midstream samples contaminated with commensals. Standard urine culture (SUC) protocols are designed in favor of growth of uropathogens at the expense of commensals. In selected clinical situations, however, it is essential to trace fastidious or new uropathogens by expanding the urine culture conditions (EUC). The aim of our study was to map the microflora in midstream urine specimens from healthy controls by means of EUC, in view of the interpretation of bacterial culture results in symptomatic patients. Midstream urine specimens from 101 healthy controls (86 females and 15 males) were examined using both SUC and EUC. Whilst 73 % of samples examined by SUC showed no growth at 10 3  colony-forming units (CFU)/mL, 91 % of samples examined by EUC grew bacterial species in large numbers (≥10 4  CFU/mL). Asymptomatic bacteriuria, as defined by the European guidelines for urinalysis, was detected in six samples with both protocols. EUC revealed 98 different species, mostly Lactobacillus, Staphylococcus, Streptococcus, and Corynebacterium. None of the samples grew Staphylococcus saprophyticus, Corynebacterium urealyticum, or Aerococcus urinae. Samples from females contained higher bacterial loads and showed higher bacterial diversity compared to males. Midstream urine of healthy controls contains large communities of living bacteria that comprise a resident microflora, only revealed by EUC. Hence, the use of EUC instead of SUC in a routine setting would result in more sensitive but less specific results, requiring critical interpretation. In our view, EUC should be reserved for limited indications.

  17. Development of Internal Controls for the Luminex Instrument as Part of a Multiplex Seven-Analyte Viral Respiratory Antibody Profile

    PubMed Central

    Martins, Thomas B.

    2002-01-01

    The ability of the Luminex system to simultaneously quantitate multiple analytes from a single sample source has proven to be a feasible and cost-effective technology for assay development. In previous studies, my colleagues and I introduced two multiplex profiles consisting of 20 individual assays into the clinical laboratory. With the Luminex instrument’s ability to classify up to 100 distinct microspheres, however, we have only begun to realize the enormous potential of this technology. By utilizing additional microspheres, it is now possible to add true internal controls to each individual sample. During the development of a seven-analyte serologic viral respiratory antibody profile, internal controls for detecting sample addition and interfering rheumatoid factor (RF) were investigated. To determine if the correct sample was added, distinct microspheres were developed for measuring the presence of sufficient quantities of immunoglobulin G (IgG) or IgM in the diluted patient sample. In a multiplex assay of 82 samples, the IgM verification control correctly identified 23 out of 23 samples with low levels (<20 mg/dl) of this antibody isotype. An internal control microsphere for RF detected 30 out of 30 samples with significant levels (>10 IU/ml) of IgM RF. Additionally, RF-positive samples causing false-positive adenovirus and influenza A virus IgM results were correctly identified. By exploiting the Luminex instrument’s multiplexing capabilities, I have developed true internal controls to ensure correct sample addition and identify interfering RF as part of a respiratory viral serologic profile that includes influenza A and B viruses, adenovirus, parainfluenza viruses 1, 2, and 3, and respiratory syncytial virus. Since these controls are not assay specific, they can be incorporated into any serologic multiplex assay. PMID:11777827

  18. Development of internal controls for the Luminex instrument as part of a multiplex seven-analyte viral respiratory antibody profile.

    PubMed

    Martins, Thomas B

    2002-01-01

    The ability of the Luminex system to simultaneously quantitate multiple analytes from a single sample source has proven to be a feasible and cost-effective technology for assay development. In previous studies, my colleagues and I introduced two multiplex profiles consisting of 20 individual assays into the clinical laboratory. With the Luminex instrument's ability to classify up to 100 distinct microspheres, however, we have only begun to realize the enormous potential of this technology. By utilizing additional microspheres, it is now possible to add true internal controls to each individual sample. During the development of a seven-analyte serologic viral respiratory antibody profile, internal controls for detecting sample addition and interfering rheumatoid factor (RF) were investigated. To determine if the correct sample was added, distinct microspheres were developed for measuring the presence of sufficient quantities of immunoglobulin G (IgG) or IgM in the diluted patient sample. In a multiplex assay of 82 samples, the IgM verification control correctly identified 23 out of 23 samples with low levels (<20 mg/dl) of this antibody isotype. An internal control microsphere for RF detected 30 out of 30 samples with significant levels (>10 IU/ml) of IgM RF. Additionally, RF-positive samples causing false-positive adenovirus and influenza A virus IgM results were correctly identified. By exploiting the Luminex instrument's multiplexing capabilities, I have developed true internal controls to ensure correct sample addition and identify interfering RF as part of a respiratory viral serologic profile that includes influenza A and B viruses, adenovirus, parainfluenza viruses 1, 2, and 3, and respiratory syncytial virus. Since these controls are not assay specific, they can be incorporated into any serologic multiplex assay.

  19. The Mediating Effect of Self-Control on Parenting and Delinquency: A Gendered Approach With a Multinational Sample.

    PubMed

    Muftić, Lisa R; Updegrove, Alexander H

    2017-08-01

    This study aims to clarify the relationships between parenting techniques, low self-control, and juvenile delinquency in Gottfredson and Hirschi's general theory of crime while controlling for alternative explanations of delinquency. We relied on a sample of 35,511 adolescent students from 31 countries from the International Self-Report Delinquency 2 Study. Results indicate that parenting exhibits a direct effect on adolescents' violence perpetration and property offending, and that while self-control weakens the strength of this relationship, it fails to fully mediate it. Males reported lower levels of self-control, exposure to poorer parenting techniques, and higher rates of violence perpetration and property offending. The relationship between parenting, self-control, and juvenile delinquency was similar for females and males. These results provide evidence that parenting has important implications for adolescents' involvement in delinquency above and beyond its influence on their level of self-control.

  20. Induced Environment Contamination Monitor (IECM), air sampler - Results from the Space Transport System (STS-2) flight

    NASA Technical Reports Server (NTRS)

    Peters, P. N.; Hester, H. B.; Bertsch, W.; Mayfield, H.; Zatko, D.

    1983-01-01

    An investigation involving sampling the rapidly changing environment of the Shuttle cargo bay is considered. Four time-integrated samples and one rapid acquisition sample were collected to determine the types and quantities of contaminants present during ascent and descent of the Shuttle. The sampling times for the various bottles were controlled by valves operated by the Data Acquisition and Control System (DACS) of the IECM. Many of the observed species were found to be common solvents used in cleaning surfaces. When the actual volume sampled is taken into account, the relative mass of organics sampled during descent is about 20 percent less than during ascent.

  1. Epstein-Barr Virus and Gastric Cancer Risk: A Meta-analysis With Meta-regression of Case-control Studies.

    PubMed

    Bae, Jong-Myon; Kim, Eun Hee

    2016-03-01

    Research on how the risk of gastric cancer increases with Epstein-Barr virus (EBV) infection is lacking. In a systematic review that investigated studies published until September 2014, the authors did not calculate the summary odds ratio (SOR) due to heterogeneity across studies. Therefore, we include here additional studies published until October 2015 and conduct a meta-analysis with meta-regression that controls for the heterogeneity among studies. Using the studies selected in the previously published systematic review, we formulated lists of references, cited articles, and related articles provided by PubMed. From the lists, only case-control studies that detected EBV in tissue samples were selected. In order to control for the heterogeneity among studies, subgroup analysis and meta-regression were performed. In the 33 case-control results with adjacent non-cancer tissue, the total number of test samples in the case and control groups was 5280 and 4962, respectively. In the 14 case-control results with normal tissue, the total number of test samples in case and control groups was 1393 and 945, respectively. Upon meta-regression, the type of control tissue was found to be a statistically significant variable with regard to heterogeneity. When the control tissue was normal tissue of healthy individuals, the SOR was 3.41 (95% CI, 1.78 to 6.51; I-squared, 65.5%). The results of the present study support the argument that EBV infection increases the risk of gastric cancer. In the future, age-matched and sex-matched case-control studies should be conducted.

  2. Presumptive Sources of Fecal Contamination in Four Tributaries to the New River Gorge National River, West Virginia, 2004

    USGS Publications Warehouse

    Mathes, Melvin V.; O'Brien, Tara L.; Strickler, Kriston M.; Hardy, Joshua J.; Schill, William B.; Lukasik, Jerzy; Scott, Troy M.; Bailey, David E.; Fenger, Terry L.

    2007-01-01

    Several methods were used to determine the sources of fecal contamination in water samples collected during September and October 2004 from four tributaries to the New River Gorge National River -- Arbuckle Creek, Dunloup Creek, Keeney Creek, and Wolf Creek. All four tributaries historically have had elevated levels of fecal coliform bacteria. The source-tracking methods used yielded various results, possibly because one or more methods failed. Sourcing methods used in this study included the detection of several human-specific and animal-specific biological or molecular markers, and library-dependent pulsed-field gel electrophoresis analysis that attempted to associate Escherichia coli bacteria obtained from water samples with animal sources by matching DNA-fragment banding patterns. Evaluation of the results of quality-control analysis indicated that pulsed-field gel electrophoresis analysis was unable to identify known-source bacteria isolates. Increasing the size of the known-source library did not improve the results for quality-control samples. A number of emerging methods, using markers in Enterococcus, human urine, Bacteroidetes, and host mitochondrial DNA, demonstrated some potential in associating fecal contamination with human or animal sources in a limited analysis of quality-control samples. All four of the human-specific markers were detected in water samples from Keeney Creek, a watershed with no centralized municipal wastewater-treatment facilities, thus indicating human sources of fecal contamination. The human-specific Bacteroidetes and host mitochondrial DNA markers were detected in water samples from Dunloup Creek, Wolf Creek, and to a lesser degree Arbuckle Creek. Results of analysis for wastewater compounds indicate that the September 27 sample from Arbuckle Creek contained numerous human tracer compounds likely from sewage. Dog, horse, chicken, and pig host mitochondrial DNA were detected in some of the water samples with the exception of the October 5 sample from Dunloup Creek. Cow, white-tailed deer, and Canada goose DNA were not detected in any of the samples collected from the four tributaries, despite the presence of these animals in the watersheds. Future studies with more rigorous quality-control analyses are needed to investigate the potential applicability and use of these emerging methods. Because many of the detections for the various methods could vary over time and with flow conditions, repeated sampling during both base flow and storm events would be necessary to more definitively determine the sources of fecal contamination for each watershed.

  3. Temperature Control Diagnostics for Sample Environments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Santodonato, Louis J; Walker, Lakeisha MH; Church, Andrew J

    2010-01-01

    In a scientific laboratory setting, standard equipment such as cryocoolers are often used as part of a custom sample environment system designed to regulate temperature over a wide range. The end user may be more concerned with precise sample temperature control than with base temperature. But cryogenic systems tend to be specified mainly in terms of cooling capacity and base temperature. Technical staff at scientific user facilities (and perhaps elsewhere) often wonder how to best specify and evaluate temperature control capabilities. Here we describe test methods and give results obtained at a user facility that operates a large sample environmentmore » inventory. Although this inventory includes a wide variety of temperature, pressure, and magnetic field devices, the present work focuses on cryocooler-based systems.« less

  4. Assessment of tissue-specific cortisol activity with regard to degeneration of the suspensory ligaments in horses with pituitary pars intermedia dysfunction.

    PubMed

    Hofberger, Sina C; Gauff, Felicia; Thaller, Denise; Morgan, Ruth; Keen, John A; Licka, Theresia F

    2018-02-01

    OBJECTIVE To identify signs of tissue-specific cortisol activity in samples of suspensory ligament (SL) and neck skin tissue from horses with and without pituitary pars intermedia dysfunction (PPID). SAMPLE Suspensory ligament and neck skin tissue samples obtained from 26 euthanized horses with and without PPID. PROCEDURES Tissue samples were collected from 12 horses with and 14 horses without PPID (controls). Two control horses had received treatment with dexamethasone; data from those horses were not used in statistical analyses. The other 12 control horses were classified as old horses (≥ 14 years old) and young horses (≤ 9 years old). Standard histologic staining, staining for proteoglycan accumulation, and immunostaining of SL and neck skin tissue sections for glucocorticoid receptors, insulin, 11β hydroxysteroid dehydrogenase type 1, and 11β hydroxysteroid dehydrogenase type 2 were performed. Findings for horses with PPID were compared with findings for young and old horses without PPID. RESULTS Compared with findings for old and young control horses, there were significantly more cells stained for glucocorticoid receptors in SL samples and for 11 β hydroxysteroid dehydrogenase type 1 in SL and skin tissue samples from horses with PPID. Insulin could not be detected in any of the SL or skin tissue samples. Horses with PPID had evidence of SL degeneration with significantly increased proteoglycan accumulation. Neck skin tissue was found to be significantly thinner in PPID-affected horses than in young control horses. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that tissue-specific dysregulation of cortisol metabolism may contribute to the SL degeneration associated with PPID in horses.

  5. Increased instrument intelligence--can it reduce laboratory error?

    PubMed

    Jekelis, Albert W

    2005-01-01

    Recent literature has focused on the reduction of laboratory errors and the potential impact on patient management. This study assessed the intelligent, automated preanalytical process-control abilities in newer generation analyzers as compared with older analyzers and the impact on error reduction. Three generations of immuno-chemistry analyzers were challenged with pooled human serum samples for a 3-week period. One of the three analyzers had an intelligent process of fluidics checks, including bubble detection. Bubbles can cause erroneous results due to incomplete sample aspiration. This variable was chosen because it is the most easily controlled sample defect that can be introduced. Traditionally, lab technicians have had to visually inspect each sample for the presence of bubbles. This is time consuming and introduces the possibility of human error. Instruments with bubble detection may be able to eliminate the human factor and reduce errors associated with the presence of bubbles. Specific samples were vortexed daily to introduce a visible quantity of bubbles, then immediately placed in the daily run. Errors were defined as a reported result greater than three standard deviations below the mean and associated with incomplete sample aspiration of the analyte of the individual analyzer Three standard deviations represented the target limits of proficiency testing. The results of the assays were examined for accuracy and precision. Efficiency, measured as process throughput, was also measured to associate a cost factor and potential impact of the error detection on the overall process. The analyzer performance stratified according to their level of internal process control The older analyzers without bubble detection reported 23 erred results. The newest analyzer with bubble detection reported one specimen incorrectly. The precision and accuracy of the nonvortexed specimens were excellent and acceptable for all three analyzers. No errors were found in the nonvortexed specimens. There were no significant differences in overall process time for any of the analyzers when tests were arranged in an optimal configuration. The analyzer with advanced fluidic intelligence demostrated the greatest ability to appropriately deal with an incomplete aspiration by not processing and reporting a result for the sample. This study suggests that preanalytical process-control capabilities could reduce errors. By association, it implies that similar intelligent process controls could favorably impact the error rate and, in the case of this instrument, do it without negatively impacting process throughput. Other improvements may be realized as a result of having an intelligent error-detection process including further reduction in misreported results, fewer repeats, less operator intervention, and less reagent waste.

  6. Analysis of Tank 38H (HTF-38-16-80, 81) and Tank 43H (HTF-43-16-82, 83) Samples for Support of the Enrichment Control and Corrosion Control Programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hay, M.

    2016-10-24

    SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The total uranium in the Tank 38H surface sample was 57.6 mg/L, while the sub-surface sample was 106 mg/L. The Tank 43H samples ranged from 50.0 to 51.9 mg/L total uranium. The U-235 percentage was consistent for all four samples at 0.62%. The total uranium and percent U-235 results appear consistent with recent Tank 38H and Tank 43H uranium measurements. The Tank 38H plutonium results show a large difference between the surface and sub-surface sample concentrations and somewhat higher concentrations than previous samples. The Pu-238 concentrationmore » is more than forty times higher in the Tank 38H sub-surface sample than the surface sample. The surface and sub-surface Tank 43H samples contain similar plutonium concentrations and are within the range of values measured on previous samples. The four samples analyzed show silicon concentrations somewhat higher than the previous sample with values ranging from 104 to 213 mg/L.« less

  7. Development of homologous viral internal controls for use in RT-PCR assays of waterborne enteric viruses.

    PubMed

    Parshionikar, Sandhya U; Cashdollar, Jennifer; Fout, G Shay

    2004-10-01

    Enteric viruses often contaminate water sources causing frequent outbreaks of gastroenteritis. Reverse transcription-polymerase chain reaction (RT-PCR) assays are commonly used for detection of human enteric viruses in environmental and drinking water samples. RT-PCR provides a means to rapidly detect low levels of these viruses, but it is sensitive to inhibitors that are present in water samples. Inhibitors of RT-PCR are concentrated along with viruses during sample processing. While procedures have been developed to remove inhibitors, none of them completely remove all inhibitors from all types of water matrices. This problem requires that adequate controls be used to distinguish true from potentially false-negative results. To address this problem, we have developed homologous viral internal controls for hepatitis A virus (HAV), poliovirus, Norwalk virus and rotavirus. These internal controls can be used in RT-PCR assays for the detection of the above viruses by competitive amplification, thereby allowing the detection of false negatives in processed water samples. The internal controls developed in this study were successfully tested with virus-seeded environmental water sample concentrates.

  8. Treatment Trials for Neonatal Seizures: The Effect of Design on Sample Size

    PubMed Central

    Stevenson, Nathan J.; Boylan, Geraldine B.; Hellström-Westas, Lena; Vanhatalo, Sampsa

    2016-01-01

    Neonatal seizures are common in the neonatal intensive care unit. Clinicians treat these seizures with several anti-epileptic drugs (AEDs) to reduce seizures in a neonate. Current AEDs exhibit sub-optimal efficacy and several randomized control trials (RCT) of novel AEDs are planned. The aim of this study was to measure the influence of trial design on the required sample size of a RCT. We used seizure time courses from 41 term neonates with hypoxic ischaemic encephalopathy to build seizure treatment trial simulations. We used five outcome measures, three AED protocols, eight treatment delays from seizure onset (Td) and four levels of trial AED efficacy to simulate different RCTs. We performed power calculations for each RCT design and analysed the resultant sample size. We also assessed the rate of false positives, or placebo effect, in typical uncontrolled studies. We found that the false positive rate ranged from 5 to 85% of patients depending on RCT design. For controlled trials, the choice of outcome measure had the largest effect on sample size with median differences of 30.7 fold (IQR: 13.7–40.0) across a range of AED protocols, Td and trial AED efficacy (p<0.001). RCTs that compared the trial AED with positive controls required sample sizes with a median fold increase of 3.2 (IQR: 1.9–11.9; p<0.001). Delays in AED administration from seizure onset also increased the required sample size 2.1 fold (IQR: 1.7–2.9; p<0.001). Subgroup analysis showed that RCTs in neonates treated with hypothermia required a median fold increase in sample size of 2.6 (IQR: 2.4–3.0) compared to trials in normothermic neonates (p<0.001). These results show that RCT design has a profound influence on the required sample size. Trials that use a control group, appropriate outcome measure, and control for differences in Td between groups in analysis will be valid and minimise sample size. PMID:27824913

  9. Association between oral lichen planus and Epstein–Barr virus in Iranian patients

    PubMed Central

    Shariati, Matin; Mokhtari, Mojgan; Masoudifar, Aria

    2018-01-01

    Background: Oral lichen planus (OLP) is a common mucocutaneous disease with malignant transformation potential. Several etiologies such as humoral, autoimmunity, and viral infections might play a role, but still there is no definite etiology for this disease. The aim of this study was to investigate the presence of Epstein–Barr virus (EBV) genome in Iranian patients with OLP as compared to people with normal mucosa. Materials and Methods: The study was carried out on a case group including 38 tissue specimens of patients with histopathological confirmation of OLP and a control group including 38 samples of healthy mucosa. All samples were examined by nested polymerase chain reaction (PCR) method to determine the DNA of EBV. Results: Twenty-two (57.9%) female samples and 16 (42.1%) male samples with OLP were randomly selected as the case group, and 20 (52.6%) female samples and 18 (47.4%) male samples with healthy mucosa as the control group. There was a statistically significant difference in the percentage of EBV positivity between the case (15.8%) and the control groups (P < 0.05); in the case group, three female samples (13.6%) and three male samples (18.8%) were infected with EBV; the difference between the genders was not statistically significant (P = 0.50). Conclusion: Results emphasized that EBV genome was significantly higher among Iranian patients with OLP so antiviral therapy might be helpful. PMID:29692821

  10. Impact of Processing Method on Recovery of Bacteria from Wipes Used in Biological Surface Sampling

    PubMed Central

    Olson, Nathan D.; Filliben, James J.; Morrow, Jayne B.

    2012-01-01

    Environmental sampling for microbiological contaminants is a key component of hygiene monitoring and risk characterization practices utilized across diverse fields of application. However, confidence in surface sampling results, both in the field and in controlled laboratory studies, has been undermined by large variation in sampling performance results. Sources of variation include controlled parameters, such as sampling materials and processing methods, which often differ among studies, as well as random and systematic errors; however, the relative contributions of these factors remain unclear. The objective of this study was to determine the relative impacts of sample processing methods, including extraction solution and physical dissociation method (vortexing and sonication), on recovery of Gram-positive (Bacillus cereus) and Gram-negative (Burkholderia thailandensis and Escherichia coli) bacteria from directly inoculated wipes. This work showed that target organism had the largest impact on extraction efficiency and recovery precision, as measured by traditional colony counts. The physical dissociation method (PDM) had negligible impact, while the effect of the extraction solution was organism dependent. Overall, however, extraction of organisms from wipes using phosphate-buffered saline with 0.04% Tween 80 (PBST) resulted in the highest mean recovery across all three organisms. The results from this study contribute to a better understanding of the factors that influence sampling performance, which is critical to the development of efficient and reliable sampling methodologies relevant to public health and biodefense. PMID:22706055

  11. The Benefits of Soft Sensor and Multi-Rate Control for the Implementation of Wireless Networked Control Systems

    PubMed Central

    Mansano, Raul K.; Godoy, Eduardo P.; Porto, Arthur J. V.

    2014-01-01

    Recent advances in wireless networking technology and the proliferation of industrial wireless sensors have led to an increasing interest in using wireless networks for closed loop control. The main advantages of Wireless Networked Control Systems (WNCSs) are the reconfigurability, easy commissioning and the possibility of installation in places where cabling is impossible. Despite these advantages, there are two main problems which must be considered for practical implementations of WNCSs. One problem is the sampling period constraint of industrial wireless sensors. This problem is related to the energy cost of the wireless transmission, since the power supply is limited, which precludes the use of these sensors in several closed-loop controls. The other technological concern in WNCS is the energy efficiency of the devices. As the sensors are powered by batteries, the lowest possible consumption is required to extend battery lifetime. As a result, there is a compromise between the sensor sampling period, the sensor battery lifetime and the required control performance for the WNCS. This paper develops a model-based soft sensor to overcome these problems and enable practical implementations of WNCSs. The goal of the soft sensor is generating virtual data allowing an actuation on the process faster than the maximum sampling period available for the wireless sensor. Experimental results have shown the soft sensor is a solution to the sampling period constraint problem of wireless sensors in control applications, enabling the application of industrial wireless sensors in WNCSs. Additionally, our results demonstrated the soft sensor potential for implementing energy efficient WNCS through the battery saving of industrial wireless sensors. PMID:25529208

  12. The Relations of Temperament Reactivity and Effortful Control to Children’s Adjustment Problems in China and the United States

    PubMed Central

    Zhou, Qing; Lengua, Liliana J.; Wang, Yun

    2014-01-01

    The relations of parents’ and teachers’ reports of temperament anger-irritability, positive emotionality, and effortful control (attention focusing and inhibitory control) to children’s externalizing and internalizing problems were examined in Chinese (N = 382) and U.S. (N = 322) samples of school-age children. Results suggested that in both cultures, low effortful control and high anger–irritability were associated with high externalizing problems, although the relations were stronger in the Chinese sample than in the U.S. sample. Low positive emotionality was associated with high internalizing problems in both cultures. However, high positive emotionality was associated with noncomorbid externalizing problems (teachers’ reports) in the Chinese sample but not in the U.S. sample. These findings suggest that there are considerable cross-cultural similarities in the temperament-adjustment associations, although some cross-cultural differences might exist. Implications of the findings for the detection and intervention of adjustment problems in Chinese children are discussed. PMID:19413428

  13. Changes in antioxidant activity and phenolic acid composition of tarhana with steel-cut oats.

    PubMed

    Kilci, A; Gocmen, D

    2014-02-15

    Steel-cut oats (SCO) was used to replace wheat flour in the tarhana formulation (control) at the levels of 10%, 20%, 30% and 40% (w/w). Control sample included no SCO. Substitution of wheat flour in tarhana formulation with SCO affected the mineral contents positively. SCO additions also increased phenolic acid contents of tarhana samples. The most abundant phenolic acids were ferulic and vanillic acids, followed by syringic acid in the samples with SCO. Tarhana samples with SCO also showed higher antioxidant activities than the control. Compared with the control, the total phenolic content increased when the level of SCO addition was increased. SCO addition did not have a deteriorative effect on sensory properties of tarhana samples and resulted in acceptable soup properties in terms of overall acceptability. SCO addition improved the nutritional and functional properties of tarhana by causing increases in antioxidant activity, phenolic content and phenolic acids. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Control of Working Memory in Rhesus Monkeys (Macaca mulatta)

    PubMed Central

    Tu, Hsiao-Wei; Hampton, Robert R.

    2014-01-01

    Cognitive control is critical for efficiently using the limited resources in working memory. It is well established that humans use rehearsal to increase the probability of remembering needed information, but little is known in nonhumans, with some studies reporting the absence of active control and others subject to alternative explanations. We trained monkeys in a visual matching-to-sample paradigm with a post-sample memory cue. Monkeys either saw a remember cue that predicted the occurrence of a matching test that required memory for the sample, or a forget cue that predicted a discrimination test that did not require memory of the sample. Infrequent probe trials on which monkeys were given tests of the type not cued on that trial were used to assess whether memory was under cognitive control. Our procedures controlled for reward expectation and for the surprising nature of the probes. Monkeys matched less accurately after forget cues, while discrimination accuracy was equivalent in the two cue conditions. We also tested monkeys with lists of two consecutive sample images that shared the same cue. Again, memory for expected memory tests was superior to that on unexpected tests. Together these results show that monkeys cognitively control their working memory. PMID:25436219

  15. Repeat sample intraocular pressure variance in induced and naturally ocular hypertensive monkeys.

    PubMed

    Dawson, William W; Dawson, Judyth C; Hope, George M; Brooks, Dennis E; Percicot, Christine L

    2005-12-01

    To compare repeat-sample means variance of laser induced ocular hypertension (OH) in rhesus monkeys with the repeat-sample mean variance of natural OH in age-range matched monkeys of similar and dissimilar pedigrees. Multiple monocular, retrospective, intraocular pressure (IOP) measures were recorded repeatedly during a short sampling interval (SSI, 1-5 months) and a long sampling interval (LSI, 6-36 months). There were 5-13 eyes in each SSI and LSI subgroup. Each interval contained subgroups from the Florida with natural hypertension (NHT), induced hypertension (IHT1) Florida monkeys, unrelated (Strasbourg, France) induced hypertensives (IHT2), and Florida age-range matched controls (C). Repeat-sample individual variance means and related IOPs were analyzed by a parametric analysis of variance (ANOV) and results compared to non-parametric Kruskal-Wallis ANOV. As designed, all group intraocular pressure distributions were significantly different (P < or = 0.009) except for the two (Florida/Strasbourg) induced OH groups. A parametric 2 x 4 design ANOV for mean variance showed large significant effects due to treatment group and sampling interval. Similar results were produced by the nonparametric ANOV. Induced OH sample variance (LSI) was 43x the natural OH sample variance-mean. The same relationship for the SSI was 12x. Laser induced ocular hypertension in rhesus monkeys produces large IOP repeat-sample variance mean results compared to controls and natural OH.

  16. Evaluation of Hygienic Quality and Labelling of Fish Distributed in Public Canteens of Northeast Italy

    PubMed Central

    Armani, Mariachiara; Civettini, Michele; Conedera, Gabriella; Favretti, Michela; Lombardo, Dorotea; Lucchini, Rosaria; Paternolli, Sabrina; Pezzuto, Alessandra; Rabini, Michela; Arcangeli, Giuseppe

    2016-01-01

    Over the past few years, the demand for the introduction of fish products in public canteens (schools, hospitals and nursing-homes) has grown due to their good nutritional proprieties. The particular health conditions and sensitivity of some groups of consumers exposes them to greater risks of food poisoning. It is therefore important to monitor the raw materials that end up in mass catering implementing strategies of mass catering control, both with self-monitoring strategies and with regular controls performed by the competent health authorities. The purpose of this study is to assess the overall quality of seafood dealt out from public catering services located in Northeast Italy. In this paper we illustrate the results of microbiological analysis performed on 135 fish samples (58% of samples were raw fishes, 27% cooked fishes, 6% raw fish products, 9% cooked fish products) and species identification performed on 102 fish samples. Additionally, 135 environmental swabs were collected to determine the effectiveness of cleaning and sanitation of food contact (cutting boards, cooking equipment and food processing surfaces) and non-contact (refrigerator wall and handle, tap lever) surfaces. Of raw seafood samples, 24% had total aerobic mesophilic bacteria count >105 CFU/g and for Enterobacteriaceae the faecal contamination was excluded since no Salmonella spp. and Escherichia coli were isolated. Just 3.8% of raw seafood samples resulted positive for Listeria monocytogenes. The results of swab samples of cooking utensils and surfaces showed that sanitation practices should be improved. Molecular analysis for fish species identification revealed a mislabelling for 25% of sampled fishes. The results of this survey can provide valuable information for monitoring and surveillance programmes for the control of quality of fish and fish products. PMID:27995098

  17. Quality control of measurements made on fixed-area sample plots

    Treesearch

    Ola Lindgren

    2000-01-01

    The paper describes results from a large program for quality control of forest measurements. The performance of 87 surveyors was evaluated. Tree heights were usually measured well, whereas the counting of tree-rings on increment cores was a source of considerable bias for many surveyors. During tree count on sample plots, many surveyors had a tendency to forget trees,...

  18. Association of classic lichen planus with human herpesvirus-7 infection.

    PubMed

    Nahidi, Yalda; Tayyebi Meibodi, Naser; Ghazvini, Kiarash; Esmaily, Habibollah; Esmaeelzadeh, Maryam

    2017-01-01

    Lichen planus is a mucocutaneous papulosquamous itchy disease with unknown etiology. A number of factors such as immune mechanisms, viral agents, and drugs have been implicated in pathogenesis of lichen planus. In recent years, several studies have indicated the role of viral agents in this disease, including human herpesvirus-7 (HHV-7). Studies have given contradictory results, which is why we decided to study the possible association between lichen planus with HHV-7. In this case-control study, which was conducted on 60 cutaneous classic lichen planus samples as well as 60 healthy control skin samples after matching the two groups in terms of gender and age, tissue samples of patients and controls were studied by real time polymerase chain reaction to detect for HHV-7. According to this study, HHV-7 DNA was found in 18 samples of the case group (30.0%) and in six (10.0%) of the control group (P = 0.006). The results of this study support the likely role of HHV-7 in pathogenesis of lichen planus. As an exogenous antigen, this virus may be involved in cellular immune-mediated destruction of keratinocytes. © 2016 The International Society of Dermatology.

  19. Synthesis of TiO2 nanotubes with ZnO nanoparticles to achieve antibacterial properties and stem cell compatibility

    NASA Astrophysics Data System (ADS)

    Liu, Wenwen; Su, Penglei; Chen, Su; Wang, Na; Ma, Yuanping; Liu, Yiran; Wang, Jinshu; Zhang, Zhenting; Li, Hongyi; Webster, Thomas J.

    2014-07-01

    To endow titanium (Ti) with antibacterial properties, different concentrations of zinc oxide (ZnO) nanoparticles were decorated on anodized titanium dioxide (TiO2) nanotubes by a simple hydrothermal treatment method. The particle sizes of ZnO, which were evenly distributed and tightly adherent to the walls of the Ti nanotubes, ranged from 20-50 nm. Results from this study showed that Zn was released from the TiO2 nanotubes in a constant, slow, and biologically inspired manner. Importantly, the results showed that the ZnO decorated TiO2 nanotubular samples inhibited Streptococcus mutants and Porphyromonas gingivalis growth compared to control unmodified Ti samples. Specifically, S. mutants and P. gingivalis growth were both reduced 45-85% on the ZnO decorated Ti samples compared to Ti controls after 7 days of culture. When examining the mechanism of action, it has been further found for the first time that the ZnO decorated Ti samples inhibited the expression of Streptococcus mutans bacterial adhesion genes. Lastly, the results showed that the same samples which decreased bacterial growth the most (0.015 M precursor Zn(NO3)2 samples) did not inhibit mesenchymal stem cell growth compared to Ti controls for up to 7 days. In summary, results from this study showed that compared to plain TiO2 nanotubes, TiO2 decorated with 0.015 M ZnO provided unprecedented antibacterial properties while maintaining the stem cell proliferation capacity necessary for enhancing the use of Ti in numerous medical applications, particularly in dentistry.

  20. Synthesis of TiO2 nanotubes with ZnO nanoparticles to achieve antibacterial properties and stem cell compatibility.

    PubMed

    Liu, Wenwen; Su, Penglei; Chen, Su; Wang, Na; Ma, Yuanping; Liu, Yiran; Wang, Jinshu; Zhang, Zhenting; Li, Hongyi; Webster, Thomas J

    2014-08-07

    To endow titanium (Ti) with antibacterial properties, different concentrations of zinc oxide (ZnO) nanoparticles were decorated on anodized titanium dioxide (TiO2) nanotubes by a simple hydrothermal treatment method. The particle sizes of ZnO, which were evenly distributed and tightly adherent to the walls of the Ti nanotubes, ranged from 20-50 nm. Results from this study showed that Zn was released from the TiO2 nanotubes in a constant, slow, and biologically inspired manner. Importantly, the results showed that the ZnO decorated TiO2 nanotubular samples inhibited Streptococcus mutants and Porphyromonas gingivalis growth compared to control unmodified Ti samples. Specifically, S. mutants and P. gingivalis growth were both reduced 45-85% on the ZnO decorated Ti samples compared to Ti controls after 7 days of culture. When examining the mechanism of action, it has been further found for the first time that the ZnO decorated Ti samples inhibited the expression of Streptococcus mutans bacterial adhesion genes. Lastly, the results showed that the same samples which decreased bacterial growth the most (0.015 M precursor Zn(NO3)2 samples) did not inhibit mesenchymal stem cell growth compared to Ti controls for up to 7 days. In summary, results from this study showed that compared to plain TiO2 nanotubes, TiO2 decorated with 0.015 M ZnO provided unprecedented antibacterial properties while maintaining the stem cell proliferation capacity necessary for enhancing the use of Ti in numerous medical applications, particularly in dentistry.

  1. A Summary of Research and Progress on Carbon Monoxide Exposure Control Solutions on Houseboats

    PubMed Central

    Hall, Ronald M.; Earnest, G. Scott; Hammond, Duane R.; Dunn, Kevin H.; Garcia, Alberto

    2015-01-01

    Investigations of carbon monoxide (CO-related poisonings and deaths on houseboats were conducted by the Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health. These investigations measured hazardous CO concentrations on and around houseboats that utilize gasoline-powered generators. Engineering control devices were developed and tested to mitigate this deadly hazard. CO emissions were measured using various sampling techniques which included exhaust emission analyzers, detector tubes, evacuated containers (grab air samples analyzed by a gas chromatograph), and direct-reading CO monitors. CO results on houseboats equipped with gasoline-powered generators without emission controls indicated hazardous CO concentrations exceeding immediately dangerous to life and health (IDLH) levels in potentially occupied areas of the houseboat. Air sample results on houseboats that were equipped with engineering controls to remove the hazard were highly effective and reduced CO levels by over 98% in potentially occupied areas. The engineering control devices used to reduce the hazardous CO emissions from gasoline-powered generators on houseboats were extremely effective at reducing CO concentrations to safe levels in potentially occupied areas on the houseboats and are now beginning to be widely used. PMID:24568306

  2. A summary of research and progress on carbon monoxide exposure control solutions on houseboats.

    PubMed

    Hall, Ronald M; Earnest, G Scott; Hammond, Duane R; Dunn, Kevin H; Garcia, Alberto

    2014-01-01

    Investigations of carbon monoxide (CO-related poisonings and deaths on houseboats were conducted by the Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health. These investigations measured hazardous CO concentrations on and around houseboats that utilize gasoline-powered generators. Engineering control devices were developed and tested to mitigate this deadly hazard. CO emissions were measured using various sampling techniques which included exhaust emission analyzers, detector tubes, evacuated containers (grab air samples analyzed by a gas chromatograph), and direct-reading CO monitors. CO results on houseboats equipped with gasoline-powered generators without emission controls indicated hazardous CO concentrations exceeding immediately dangerous to life and health (IDLH) levels in potentially occupied areas of the houseboat. Air sample results on houseboats that were equipped with engineering controls to remove the hazard were highly effective and reduced CO levels by over 98% in potentially occupied areas. The engineering control devices used to reduce the hazardous CO emissions from gasoline-powered generators on houseboats were extremely effective at reducing CO concentrations to safe levels in potentially occupied areas on the houseboats and are now beginning to be widely used.

  3. Temperature-dependent quality characteristics of pre-dehydrated cookies: structure, browning, texture, in vitro starch digestibility, and the effect on blood glucose levels in mice.

    PubMed

    Kawai, Kiyoshi; Matsusaki, Keiko; Hando, Kana; Hagura, Yoshio

    2013-11-01

    The purpose of this study was to elucidate the physical and biochemical properties of pre-dehydrated cookies baked at various temperatures. Cookie dough was vacuum-dried, and then baked at 120-180°C for 18 min. All samples showed lower spread ratio than non-dehydrated cookie baked at 180°C (control). Browning of the samples baked at 180°C and 160°C was higher than that of the control. In contrast, little browning was observed in the sample baked at 120°C. The fracture force of samples baked at 140°C and 120°C agreed well with the control. From these results, the sample baked at 140°C was employed for subsequent studies. In vitro starch digestibility suggested that the sample baked at 140°C had higher slowly digestible starch content than the control. From postprandial blood glucose levels in mice, it was found that the sample significantly reduced the blood glucose peak observed at 30 min post-administration. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Key considerations for the experimental training and evaluation of cancer odour detection dogs: lessons learnt from a double-blind, controlled trial of prostate cancer detection

    PubMed Central

    2014-01-01

    Background Cancer detection using sniffer dogs is a potential technology for clinical use and research. Our study sought to determine whether dogs could be trained to discriminate the odour of urine from men with prostate cancer from controls, using rigorous testing procedures and well-defined samples from a major research hospital. Methods We attempted to train ten dogs by initially rewarding them for finding and indicating individual prostate cancer urine samples (Stage 1). If dogs were successful in Stage 1, we then attempted to train them to discriminate prostate cancer samples from controls (Stage 2). The number of samples used to train each dog varied depending on their individual progress. Overall, 50 unique prostate cancer and 67 controls were collected and used during training. Dogs that passed Stage 2 were tested for their ability to discriminate 15 (Test 1) or 16 (Tests 2 and 3) unfamiliar prostate cancer samples from 45 (Test 1) or 48 (Tests 2 and 3) unfamiliar controls under double-blind conditions. Results Three dogs reached training Stage 2 and two of these learnt to discriminate potentially familiar prostate cancer samples from controls. However, during double-blind tests using new samples the two dogs did not indicate prostate cancer samples more frequently than expected by chance (Dog A sensitivity 0.13, specificity 0.71, Dog B sensitivity 0.25, specificity 0.75). The other dogs did not progress past Stage 1 as they did not have optimal temperaments for the sensitive odour discrimination training. Conclusions Although two dogs appeared to have learnt to select prostate cancer samples during training, they did not generalise on a prostate cancer odour during robust double-blind tests involving new samples. Our study illustrates that these rigorous tests are vital to avoid drawing misleading conclusions about the abilities of dogs to indicate certain odours. Dogs may memorise the individual odours of large numbers of training samples rather than generalise on a common odour. The results do not exclude the possibility that dogs could be trained to detect prostate cancer. We recommend that canine olfactory memory is carefully considered in all future studies and rigorous double-blind methods used to avoid confounding effects. PMID:24575737

  5. A device for automatic photoelectric control of the analytical gap for emission spectrographs

    USGS Publications Warehouse

    Dietrich, John A.; Cooley, Elmo F.; Curry, Kenneth J.

    1977-01-01

    A photoelectric device has been built that automatically controls the analytical gap between electrodes during excitation period. The control device allows for precise control of the analytical gap during the arcing process of samples, resulting in better precision of analysis.

  6. A robust variable sampling time BLDC motor control design based upon μ-synthesis.

    PubMed

    Hung, Chung-Wen; Yen, Jia-Yush

    2013-01-01

    The variable sampling rate system is encountered in many applications. When the speed information is derived from the position marks along the trajectory, one would have a speed dependent sampling rate system. The conventional fixed or multisampling rate system theory may not work in these cases because the system dynamics include the uncertainties which resulted from the variable sampling rate. This paper derived a convenient expression for the speed dependent sampling rate system. The varying sampling rate effect is then translated into multiplicative uncertainties to the system. The design then uses the popular μ-synthesis process to achieve a robust performance controller design. The implementation on a BLDC motor demonstrates the effectiveness of the design approach.

  7. A Robust Variable Sampling Time BLDC Motor Control Design Based upon μ-Synthesis

    PubMed Central

    Yen, Jia-Yush

    2013-01-01

    The variable sampling rate system is encountered in many applications. When the speed information is derived from the position marks along the trajectory, one would have a speed dependent sampling rate system. The conventional fixed or multisampling rate system theory may not work in these cases because the system dynamics include the uncertainties which resulted from the variable sampling rate. This paper derived a convenient expression for the speed dependent sampling rate system. The varying sampling rate effect is then translated into multiplicative uncertainties to the system. The design then uses the popular μ-synthesis process to achieve a robust performance controller design. The implementation on a BLDC motor demonstrates the effectiveness of the design approach. PMID:24327804

  8. Apparatus for Measuring Total Emissivity of Small, Low-Emissivity Samples

    NASA Technical Reports Server (NTRS)

    Tuttle, James; DiPirro, Michael J.

    2011-01-01

    An apparatus was developed for measuring total emissivity of small, lightweight, low-emissivity samples at low temperatures. The entire apparatus fits inside a small laboratory cryostat. Sample installation and removal are relatively quick, allowing for faster testing. The small chamber surrounding the sample is lined with black-painted aluminum honeycomb, which simplifies data analysis. This results in the sample viewing a very high-emissivity surface on all sides, an effect which would normally require a much larger chamber volume. The sample and chamber temperatures are individually controlled using off-the-shelf PID (proportional integral derivative) controllers, allowing flexibility in the test conditions. The chamber can be controlled at a higher temperature than the sample, allowing a direct absorptivity measurement. The lightweight sample is suspended by its heater and thermometer leads from an isothermal bar external to the chamber. The wires run out of the chamber through small holes in its corners, and the wires do not contact the chamber itself. During a steady-state measurement, the thermometer and bar are individually controlled at the same temperature, so there is zero heat flow through the wires. Thus, all of sample-temperature-control heater power is radiated to the chamber. Double-aluminized Kapton (DAK) emissivity was studied down to 10 K, which was about 25 K colder than any previously reported measurements. This verified a minimum in the emissivity at about 35 K and a rise as the temperature dropped to lower values.

  9. Aerobic Capacity and Cognitive Control in Elementary School-Age Children

    PubMed Central

    Scudder, Mark R.; Lambourne, Kate; Drollette, Eric S.; Herrmann, Stephen; Washburn, Richard; Donnelly, Joseph E.; Hillman, Charles H.

    2014-01-01

    Purpose The current study examined the relationship between children’s performance on the Progressive Aerobic Cardiovascular Endurance Run (PACER) subtest of the FitnessGram® and aspects of cognitive control that are believed to support academic success. Methods Hierarchical linear regression analyses were conducted on a sample of 2nd and 3rd grade children (n = 397) who completed modified versions of a flanker task and spatial n-back task to assess inhibitory control and working memory, respectively. Results Greater aerobic fitness was significantly related to shorter reaction time and superior accuracy during the flanker task, suggesting better inhibitory control and the facilitation of attention in higher fit children. A similar result was observed for the n-back task such that higher fit children exhibited more accurate target detection and discrimination performance when working memory demands were increased. Conclusion These findings support the positive association between aerobic fitness and multiple aspects of cognitive control in a large sample of children, using a widely implemented and reliable field estimate of aerobic capacity. Importantly, the current results suggest that this relationship is consistent across methods used to assess fitness, which may have important implications for extending this research to more representative samples of children in a variety of experimental contexts. PMID:24743109

  10. Identification of potential internal control genes for real-time PCR analysis during stress response in Pyropia haitanensis

    NASA Astrophysics Data System (ADS)

    Wang, Xia; Feng, Jianhua; Huang, Aiyou; He, Linwen; Niu, Jianfeng; Wang, Guangce

    2017-11-01

    Pyropia haitanensis has prominent stress-resistance characteristics and is endemic to China. Studies into the stress responses in these algae could provide valuable information on the stress-response mechanisms in the intertidal Rhodophyta. Here, the effects of salinity and light intensity on the quantum yield of photosystem II in Py. haitanensis were investigated using pulse-amplitude-modulation fluorometry. Total RNA and genomic DNA of the samples under different stress conditions were isolated. By normalizing to the genomic DNA quantity, the RNA content in each sample was evaluated. The cDNA was synthesized and the expression levels of seven potential internal control genes were evaluated using qRT-PCR method. Then, we used geNorm, a common statistical algorithm, to analyze the qRT-PCR data of seven reference genes. Potential genes that may constantly be expressed under different conditions were selected, and these genes showed stable expression levels in samples under a salinity treatment, while tubulin, glyceraldehyde-3-phosphate dehydrogenase and actin showed stability in samples stressed by strong light. Based on the results of the pulse amplitude-modulation fluorometry, an absolute quantification was performed to obtain gene copy numbers in certain stress-treated samples. The stably expressed genes as determined by the absolute quantification in certain samples conformed to the results of the geNorm screening. Based on the results of the software analysis and absolute quantification, we proposed that elongation factor 3 and 18S ribosomal RNA could be used as internal control genes when the Py. haitanensis blades were subjected to salinity stress, and that α-tubulin and 18S ribosomal RNA could be used as the internal control genes when the stress was from strong light. In general, our findings provide a convenient reference for the selection of internal control genes when designing experiments related to stress responses in Py. haitanensis.

  11. Association study of dopamine D3 receptor gene and schizophrenia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kennedy, J.L.; Billett, E.A.; Macciardi, F.M.

    Several groups have reported an association between schizophrenia and the MscI polymorphism in the first exon of the dopamine D3 receptor gene (DRD3). We studied this polymorphism using a North American sample (117 patients plus 188 controls) and an Italian sample (97 patients plus 64 controls). In the first part of the study, we compared allele frequencies of schizophrenia patients and unmatched controls and observed a significant difference in the total sample (P = 0.01). The second part of the study involved a case control approach in which each schizophrenia patient was matched to a control of the same sex,more » and of similar age and ethnic background. The DRD3 allele frequencies of patients and controls revealed no significant difference between the two groups in the Italian (N = 53) or the North American (N = 54) matched populations; however, when these two matched samples were combined, a significant difference was observed (P = 0.026). Our results suggest that the MscI polymorphism may be associated with schizophrenia in the populations studied. 32 refs., 2 tabs.« less

  12. Frozen yogurt with added inulin and isomalt.

    PubMed

    Isik, U; Boyacioglu, D; Capanoglu, E; Erdil, D Nilufer

    2011-04-01

    The objective of this study was to produce a frozen yogurt containing low fat and no added sugar. Samples containing 5% polydextrose, 0.065% aspartame and acesulfame-K mixture, and different levels of inulin and isomalt (5.0, 6.5, and 8.0%) were produced at pilot scale and analyzed for their physical and chemical properties including proximate composition, viscosity, acidity, overrun, melting rate, heat shock stability, as well as sensory characteristics, and viability of lactic acid bacteria. With the addition of inulin and isomalt, viscosity increased by 19 to 52% compared with that of sample B (reduced-fat control). The average calorie values of samples substituted with sweeteners were about 43% lower than that of original sample. Low-calorie frozen yogurt samples melted about 33 to 48% slower than the reduced-fat control sample at 45 min. Based on quantitative descriptive profile test results, statistically significant differences among products were observed for hardness, iciness, foamy melting, whey separation, and sweetness characteristics. The results of principal component analysis showed that the sensory properties of the sample containing 6.5% inulin and 6.5% isomalt were similar to those of control. Lactic acid bacteria counts of frozen yogurt were found to be between 8.12 and 8.49 log values, 3 mo after the production. The overall results showed that it is possible to produce an attractive frozen yogurt product with the incorporation of inulin and isomalt with no added sugar and reduced fat. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  13. Designing Case-Control Studies: Decisions About the Controls

    PubMed Central

    Hodge, Susan E.; Subaran, Ryan L.; Weissman, Myrna M.; Fyer, Abby J.

    2014-01-01

    The authors quantified, first, the effect of misclassified controls (i.e., individuals who are affected with the disease under study but who are classified as controls) on the ability of a case-control study to detect an association between a disease and a genetic marker, and second, the effect of leaving misclassified controls in the study, as opposed to removing them (thus decreasing sample size). The authors developed an informativeness measure of a study’s ability to identify real differences between cases and controls. They then examined this measure’s behavior when there are no misclassified controls, when there are misclassified controls, and when there were misclassified controls but they have been removed from the study. The results show that if, for example, 10% of controls are misclassified, the study’s informativeness is reduced to approximately 81% of what it would have been in a sample with no misclassified controls, whereas if these misclassified controls are removed from the study, the informativeness is only reduced to about 90%, despite the reduced sample size. If 25% are misclassified, those figures become approximately 56% and 75%, respectively. Thus, leaving the misclassified controls in the control sample is worse than removing them altogether. Finally, the authors illustrate how insufficient power is not necessarily circumvented by having an unlimited number of controls. The formulas provided by the authors enable investigators to make rational decisions about removing misclassified controls or leaving them in. PMID:22854929

  14. Investigations of the microbial transformation of cortisol to prednisolone in urine samples.

    PubMed

    Bredehöft, Michael; Baginski, Rainer; Parr, Maria-Kristina; Thevis, Mario; Schänzer, Wilhelm

    2012-03-01

    Doping control samples are normally collected under non-sterile conditions and sometimes, storage and transportation are influenced by parameters such as the temperature. Therefore, microbial contamination and subsequent alteration of a sample's composition are possible. Studies regarding sample collection in cattle breeding have already shown enzymatic transformation of endogenous testosterone to boldenone causing false-positive findings. The aim of the present study was to investigate whether positive doping cases with the synthetic corticosteroids prednisolone and prednisone may result from microbial transformation of the endogenous corticosteroids cortisol and cortisone, respectively. A method comprising parameters such as pH values and screening results for synthetic glucocorticosteroids as well as incubation experiments followed by liquid chromatographic and mass spectrometric analysis was employed to test for contaminating germs with Δ(1)-dehydrogenase activity. Over 700 urine samples comprising inpatient and doping control specimens were investigated. In none of them, 1,2-dehydrogenating activity was confirmed. These findings are in accordance with other studies. However, the problem of microbial alteration of doping control specimens with special respect to 1,2-dehydrogenation must not be underestimated. Article from a special issue on steroids and microorganisms. Copyright © 2010 Elsevier Ltd. All rights reserved.

  15. Radionuclide Concentrations in Honey Bees from Area G at TA-54 during 1999

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    T. K. Haarmann; P. R. Fresquez

    Honey bees were collected from two colonies located at Los Alamos National Laboratory's Area G, Technical Area 54, and from one control (background) colony located near Jemez Springs, NM. Samples were analyzed for various radionuclides. Area G sample results from both colonies were higher than the upper (95%) level background concentration for {sup 3}H. Sample results from one colony were higher than the upper (95%) level background concentration for total uranium, while sample results from the other colony were higher than the upper (95%) level background concentration for {sup 90}Sr.

  16. Innovative flow controller for time integrated passive sampling using SUMMA canisters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simon, P.; Farant, J.P.; Cole, H.

    1996-12-31

    To restrict the entry of gaseous contaminants inside evacuated vessels such as SUMMA canisters, mechanical flow controllers are used to collect integrated atmospheric samples. From the passive force generated by the pressure gradient, the motion of gas can be controlled to obtain a constant flow rate. Presently, devices based on the principle of critical orifices are used and they are all limited to an upper integrated sampling time. A novel flow controller which can be designed to achieve any desired sampling time when used on evacuated vessels was recently developed. It can extend the sampling time for hours, days, weeksmore » or even months for the benefits of environmental, engineering and toxicological professionals. The design of the controller is obtained from computer simulations done with an original set of equations derived from fluid mechanic and gas kinetic laws. To date, the experimental results have shown excellent agreement, with predictions obtained from the mathematical model. This new controller has already found numerous applications. Units able to deliver a constant sampling rate between vacuum and approximately -10 inches Hg during continuous long term duration have been used with SUMMA canisters of different volumes (500 ml, 1 litre and 61). Essentially, any combination of sampling time and sampler volume is possible. The innovative flow controller has contributed to an air quality assessment around a sanitary landfill (indoor/outdoor), and inside domestic wastewater and pulpmill sludge treatment facilities. It is presently being used as an alternative methodology for atmospheric sampling in the Russian orbital station Mir. This device affords true long term passive monitoring of selected gaseous air pollutants for environmental studies. 14 refs., 3 figs.« less

  17. PCR examination of bronchoalveolar lavage samples is a useful tool in pre-clinical diagnosis of ovine pulmonary adenocarcinoma (Jaagsiekte).

    PubMed

    Voigt, K; Brügmann, M; Huber, K; Dewar, P; Cousens, C; Hall, M; Sharp, J M; Ganter, M

    2007-12-01

    Ovine pulmonary adenocarcinoma (OPA) is a contagious lung tumour of sheep caused by Jaagsiekte sheep retrovirus (JSRV). The disease is a particular problem in flocks in many parts of the world. The aim of the study was to assess screening methods for individual animals as a prelude to future eradication trials. Results of histological examination were used as the standard to evaluate the relative sensitivity and specificity of an established heminested polymerase chain reaction (PCR) test for JSRV proviral DNA from blood and bronchoalveolar lavage (BAL) samples. PCR results from tissue samples are included as control data. PCR testing of blood samples was found to have an estimated sensitivity of only 10% (95% confidence interval (CI) 3-20) while the sensitivity of the PCR test on BAL samples was 89% (CI 79-96) in comparison to the results of histological examination. We conclude that PCR testing of BAL samples is an effective confirmatory test for sheep with suspected clinical OPA. It is also a useful tool for the pre-clinical identification of individual infected sheep within an infected flock and therefore may prove beneficial in future control or eradication programmes.

  18. Linkage disequilibria at the D[sub 2] dopamine receptor locus (DRD2) in alcoholics and controls

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Suarez, B.K.; Parsian, A.; Hampe, C.L.

    1994-01-01

    Because of its central role in the neuromodulation of appetitive behaviors, the D[sub 2] dopamine receptor gene (DRD2) has received considerable scrutiny as a possible candidate that may affect susceptibility to addictive behaviors--especially alcoholism. Association studies that compare the frequencies of anonymous restriction fragment length polymorphisms (RFLPs) in alcoholics and controls have yielded equivocal results, suggesting that any role played by this receptor will account for only part of the variation. Since these RFLPs are not located in coding regions, the hypothesis has been advanced that the association seen in some studies results from linkage disequilibrium between these markers andmore » one or more functional DRD2 alleles that affect susceptibility. To test this hypothesis, the authors have assayed four DRD2 RFLPs that span coding regions as well as a 3[prime] flanking RFLP in an expanded sample of 88 unrelated Caucasian alcoholics and 89 unrelated race-matched controls. No significant difference for any RFLP frequency between these samples was observed, although for one marker (phD2-244), the alcoholic sample showed a significant departure from the Hardy-Weinberg equilibrium. The pattern of pairwise composite disequilibrium coefficients is broadly similar in the two samples, although when the five-marker haplotype frequencies are compared, a significant difference is revealed. This difference appears to be due to greater linkage disequilibrium of the control sample. These results do not support the involvement of the DRD2 region in the etiology of alcoholism. 64 refs., 2 figs., 6 tabs.« less

  19. Doping control analysis at the Rio 2016 Olympic and Paralympic Games.

    PubMed

    Pereira, Henrique Marcelo Gualberto; Sardela, Vinicius Figueiredo; Padilha, Monica Costa; Mirotti, Luciana; Casilli, Alessandro; de Oliveira, Fabio Azamor; de Albuquerque Cavalcanti, Gustavo; Rodrigues, Lucas Martins Lisandro; de Araujo, Amanda Lessa Dutra; Levy, Rachel Santos; Teixeira, Pedro Antonio Castelo; de Oliveira, Felipe Alves Gomes; Duarte, Ana Carolina Giordani; Carneiro, Ana Carolina Dudenhoeffer; Evaristo, Joseph Albert Medeiros; Dos Santos, Gustavo Ramalho Cardoso; da Costa, Giovanni Carlo Verissimo; de Lima Castro, Fernando; Nogueira, Fabio Cesar Sousa; Scalco, Fernanda Bertão; Pizzatti, Luciana; de Aquino Neto, Francisco Radler

    2017-11-01

    This paper summarises the results obtained from the doping control analyses performed during the Summer XXXI Olympic Games (August 3-21, 2016) and the XV Paralympic Games (September 7-18, 2016). The analyses of all doping control samples were performed at the Brazilian Doping Control Laboratory (LBCD), a World Anti-Doping Agency (WADA)-accredited laboratory located in Rio de Janeiro, Brazil. A new facility at Rio de Janeiro Federal University (UFRJ) was built and fully operated by over 700 professionals, including Brazilian and international scientists, administrative staff, and volunteers. For the Olympic Games, 4913 samples were analysed. In 29 specimens, the presence of a prohibited substance was confirmed, resulting in adverse analytical findings (AAFs). For the Paralympic Games, 1687 samples were analysed, 12 of which were reported as AAFs. For both events, 82.8% of the samples were urine, and 17.2% were blood samples. In total, more than 31 000 analytical procedures were conducted. New WADA technical documents were fully implemented; consequently, state-of-the-art analytical toxicology instrumentation and strategies were applied during the Games, including different types of mass spectrometry (MS) analysers, peptide, and protein detection strategies, endogenous steroid profile measurements, and blood analysis. This enormous investment yielded one of the largest Olympic legacies in Brazil and South America. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  20. Portable Dew Point Mass Spectrometry System for Real-Time Gas and Moisture Analysis

    NASA Technical Reports Server (NTRS)

    Arkin, C.; Gillespie, Stacey; Ratzel, Christopher

    2010-01-01

    A portable instrument incorporates both mass spectrometry and dew point measurement to provide real-time, quantitative gas measurements of helium, nitrogen, oxygen, argon, and carbon dioxide, along with real-time, quantitative moisture analysis. The Portable Dew Point Mass Spectrometry (PDP-MS) system comprises a single quadrupole mass spectrometer and a high vacuum system consisting of a turbopump and a diaphragm-backing pump. A capacitive membrane dew point sensor was placed upstream of the MS, but still within the pressure-flow control pneumatic region. Pressure-flow control was achieved with an upstream precision metering valve, a capacitance diaphragm gauge, and a downstream mass flow controller. User configurable LabVIEW software was developed to provide real-time concentration data for the MS, dew point monitor, and sample delivery system pressure control, pressure and flow monitoring, and recording. The system has been designed to include in situ, NIST-traceable calibration. Certain sample tubing retains sufficient water that even if the sample is dry, the sample tube will desorb water to an amount resulting in moisture concentration errors up to 500 ppm for as long as 10 minutes. It was determined that Bev-A-Line IV was the best sample line to use. As a result of this issue, it is prudent to add a high-level humidity sensor to PDP-MS so such events can be prevented in the future.

  1. [Automatic adjustment control system for DC glow discharge plasma source].

    PubMed

    Wan, Zhen-zhen; Wang, Yong-qing; Li, Xiao-jia; Wang, Hai-zhou; Shi, Ning

    2011-03-01

    There are three important parameters in the DC glow discharge process, the discharge current, discharge voltage and argon pressure in discharge source. These parameters influence each other during glow discharge process. This paper presents an automatic control system for DC glow discharge plasma source. This system collects and controls discharge voltage automatically by adjusting discharge source pressure while the discharge current is constant in the glow discharge process. The design concept, circuit principle and control program of this automatic control system are described. The accuracy is improved by this automatic control system with the method of reducing the complex operations and manual control errors. This system enhances the control accuracy of glow discharge voltage, and reduces the time to reach discharge voltage stability. The glow discharge voltage stability test results with automatic control system are provided as well, the accuracy with automatic control system is better than 1% FS which is improved from 4% FS by manual control. Time to reach discharge voltage stability has been shortened to within 30 s by automatic control from more than 90 s by manual control. Standard samples like middle-low alloy steel and tin bronze have been tested by this automatic control system. The concentration analysis precision has been significantly improved. The RSDs of all the test result are better than 3.5%. In middle-low alloy steel standard sample, the RSD range of concentration test result of Ti, Co and Mn elements is reduced from 3.0%-4.3% by manual control to 1.7%-2.4% by automatic control, and that for S and Mo is also reduced from 5.2%-5.9% to 3.3%-3.5%. In tin bronze standard sample, the RSD range of Sn, Zn and Al elements is reduced from 2.6%-4.4% to 1.0%-2.4%, and that for Si, Ni and Fe is reduced from 6.6%-13.9% to 2.6%-3.5%. The test data is also shown in this paper.

  2. Anthelmintic Intake on the Nutritional Status, Hemoglobin Content, and Learning Achievement of the Elementary School Student in Sukarami Palembang

    NASA Astrophysics Data System (ADS)

    Hartati; Aryanti, S.; Muherman, S. Y.

    2017-03-01

    The main purpose study was to find out the effect of once a year of 400 mg albendazole on the nutritional status and learning achievement of elementary school students in Sukarami Palembang. Methods study used quasi experimental research with non -equivalent control group pretest-posttest design. This study was conducted in Palembang, South Sumatera for one year. Samples of this study were 1914 students deriving from a systematic stratified random sampling and divided into 2 groups: 986 students for the treatment samples were given 400 mg albendazole and 928 students for the controlled samples were given placebo. The result of this study found that there was a decrease in the prevalence of worm infection both in the treatment and controlled samples. However the number of infected students in the treatment samples decreased. The implication research is the drug albendazole worm declared as the most effective drug to treat intestinal worm infections.

  3. Evaluation of needle trap micro-extraction and automatic alveolar sampling for point-of-care breath analysis.

    PubMed

    Trefz, Phillip; Rösner, Lisa; Hein, Dietmar; Schubert, Jochen K; Miekisch, Wolfram

    2013-04-01

    Needle trap devices (NTDs) have shown many advantages such as improved detection limits, reduced sampling time and volume, improved stability, and reproducibility if compared with other techniques used in breath analysis such as solid-phase extraction and solid-phase micro-extraction. Effects of sampling flow (2-30 ml/min) and volume (10-100 ml) were investigated in dry gas standards containing hydrocarbons, aldehydes, and aromatic compounds and in humid breath samples. NTDs contained (single-bed) polymer packing and (triple-bed) combinations of divinylbenzene/Carbopack X/Carboxen 1000. Substances were desorbed from the NTDs by means of thermal expansion and analyzed by gas chromatography-mass spectrometry. An automated CO2-controlled sampling device for direct alveolar sampling at the point-of-care was developed and tested in pilot experiments. Adsorption efficiency for small volatile organic compounds decreased and breakthrough increased when sampling was done with polymer needles from a water-saturated matrix (breath) instead from dry gas. Humidity did not affect analysis with triple-bed NTDs. These NTDs showed only small dependencies on sampling flow and low breakthrough from 1-5 %. The new sampling device was able to control crucial parameters such as sampling flow and volume. With triple-bed NTDs, substance amounts increased linearly with increasing sample volume when alveolar breath was pre-concentrated automatically. When compared with manual sampling, automatic sampling showed comparable or better results. Thorough control of sampling and adequate choice of adsorption material is mandatory for application of needle trap micro-extraction in vivo. The new CO2-controlled sampling device allows direct alveolar sampling at the point-of-care without the need of any additional sampling, storage, or pre-concentration steps.

  4. Quality Control in Clinical Laboratory Samples

    DTIC Science & Technology

    2015-01-01

    is able to find and correct flaws in the analytical processes of a lab before potentially incorrect patient resu lts are released. According to...verifi es that the results produced are accurate and precise . Clinical labs use management of documentation as well as inco rporation of a continuous...improvement process to streamline the overall quality control process . QC samples are expected to be identical and tested identically to patient

  5. Emergence of Complex Conditional Discriminations by Joint Control of Compound Samples

    ERIC Educational Resources Information Center

    Alonso-Alvarez, Benigno; Perez-Gonzalez, Luis Antonio

    2006-01-01

    The goal of the present study was to explore the emergence of verbal behavior resulting from the joint control of two antecedent stimuli that are presented together for the first time. Conditional discriminations were used for teaching and for probing. Four stimuli PI, P2, 0 1 , and 02 were samples and four stimuli Al, A2, BI, and B2 were the…

  6. Selection bias in population-based cancer case-control studies due to incomplete sampling frame coverage.

    PubMed

    Walsh, Matthew C; Trentham-Dietz, Amy; Gangnon, Ronald E; Nieto, F Javier; Newcomb, Polly A; Palta, Mari

    2012-06-01

    Increasing numbers of individuals are choosing to opt out of population-based sampling frames due to privacy concerns. This is especially a problem in the selection of controls for case-control studies, as the cases often arise from relatively complete population-based registries, whereas control selection requires a sampling frame. If opt out is also related to risk factors, bias can arise. We linked breast cancer cases who reported having a valid driver's license from the 2004-2008 Wisconsin women's health study (N = 2,988) with a master list of licensed drivers from the Wisconsin Department of Transportation (WDOT). This master list excludes Wisconsin drivers that requested their information not be sold by the state. Multivariate-adjusted selection probability ratios (SPR) were calculated to estimate potential bias when using this driver's license sampling frame to select controls. A total of 962 cases (32%) had opted out of the WDOT sampling frame. Cases age <40 (SPR = 0.90), income either unreported (SPR = 0.89) or greater than $50,000 (SPR = 0.94), lower parity (SPR = 0.96 per one-child decrease), and hormone use (SPR = 0.93) were significantly less likely to be covered by the WDOT sampling frame (α = 0.05 level). Our results indicate the potential for selection bias due to differential opt out between various demographic and behavioral subgroups of controls. As selection bias may differ by exposure and study base, the assessment of potential bias needs to be ongoing. SPRs can be used to predict the direction of bias when cases and controls stem from different sampling frames in population-based case-control studies.

  7. Innovations in Rheometer Controlled-Rate Control Loop Design: Ultra Low Angular Speed Control and New Applications

    NASA Astrophysics Data System (ADS)

    Schulz, Ulrich; Sierro, Philippe; Nijman, Jint

    2008-07-01

    The design and implementation of an angular speed control loop for a universal rheometer is not a trivial task. The combination of a highly dynamic, very low inertia (drag cup) motor (motor inertia is 10-5 kg m2) with samples which can range in viscosity from 10-3 Pas to 108 Pas, which can be between purely viscous and higly viscoelastic, which can exhibit yield-stresses, etc. asks for a highly adaptive digital control loop. For the HAAKE MARS rotational rheometer a new adaptive control loop was developed which allows the control of angular speeds as low 5×10-9 rad/s and response times a short as 10 ms. The adaptation of the control loop to "difficult" samples is performed by analysing the response of the complete system to a short pre-test. In this paper we will show that the (very) short response times at (very) low angular speeds are not only achieved with ideal samples, but due to the adaptable control loop, also with "difficult" samples. We will show measurement results on "difficult" samples like cosmetic creams and emulsions, a laponite gel, etc. to proof that angular speeds down to 10-4 rad/s are reached within 10 ms to 20 ms and angular speeds down to 10-7 rad/s within 1 s to 2 s. The response times for reaching ultra low angular speeds down to 5×10-9 rad/s are in the order of 10 s to 30 s. With this new control loop it is, for the first time, possible to measure yield stresses by applying a very low constant shear-rate to the sample and measuring the torque response as a function of time.

  8. Characterizing concentrations of diethylene glycol and suspected metabolites in human serum, urine, and cerebrospinal fluid samples from the Panama DEG mass poisoning.

    PubMed

    Schier, J G; Hunt, D R; Perala, A; McMartin, K E; Bartels, M J; Lewis, L S; McGeehin, M A; Flanders, W D

    2013-12-01

    Diethylene glycol (DEG) mass poisoning is a persistent public health problem. Unfortunately, there are no human biological data on DEG and its suspected metabolites in poisoning. If present and associated with poisoning, the evidence for use of traditional therapies such as fomepizole and/or hemodialysis would be much stronger. To characterize DEG and its metabolites in stored serum, urine, and cerebrospinal fluid (CSF) specimens obtained from human DEG poisoning victims enrolled in a 2006 case-control study. In the 2006 study, biological samples from persons enrolled in a case-control study (42 cases with new-onset, unexplained AKI and 140 age-, sex-, and admission date-matched controls without AKI) were collected and shipped to the Centers for Disease Control and Prevention (CDC) in Atlanta for various analyses and were then frozen in storage. For this study, when sufficient volume of the original specimen remained, the following analytes were quantitatively measured in serum, urine, and CSF: DEG, 2-hydroxyethoxyacetic acid (HEAA), diglycolic acid, ethylene glycol, glycolic acid, and oxalic acid. Analytes were measured using low resolution GC/MS, descriptive statistics calculated and case results compared with controls when appropriate. Specimens were de-identified so previously collected demographic, exposure, and health data were not available. The Wilcoxon Rank Sum test (with exact p-values) and bivariable exact logistic regression were used in SAS v9.2 for data analysis. The following samples were analyzed: serum, 20 case, and 20 controls; urine, 11 case and 22 controls; and CSF, 11 samples from 10 cases and no controls. Diglycolic acid was detected in all case serum samples (median, 40.7 mcg/mL; range, 22.6-75.2) and no controls, and in all case urine samples (median, 28.7 mcg/mL; range, 14-118.4) and only five (23%) controls (median, < Lower Limit of Quantitation (LLQ); range, < LLQ-43.3 mcg/mL). Significant differences and associations were identified between case status and the following: 1) serum oxalic acid and serum HEAA (both OR = 14.6; 95% C I = 2.8-100.9); 2) serum diglycolic acid and urine diglycolic acid (both OR > 999; exact p < 0.0001); and 3) urinary glycolic acid (OR = 0.057; 95% C I = 0.001-0.55). Two CSF sample results were excluded and two from the same case were averaged, yielding eight samples from eight cases. Diglycolic acid was detected in seven (88%) of case CSF samples (median, 2.03 mcg/mL; range, < LLQ, 7.47). Significantly elevated HEAA (serum) and diglycolic acid (serum and urine) concentrations were identified among cases, which is consistent with animal data. Low urinary glycolic acid concentrations in cases may have been due to concurrent AKI. Although serum glycolic concentrations among cases may have initially increased, further metabolism to oxalic acid may have occurred thereby explaining the similar glycolic acid concentrations in cases and controls. The increased serum oxalic acid concentration results in cases versus controls are consistent with this hypothesis. Diglycolic acid is associated with human DEG poisoning and may be a biomarker for poisoning. These findings add to animal data suggesting a possible role for traditional antidotal therapies. The detection of HEAA and diglycolic acid in the CSF of cases suggests a possible association with signs and symptoms of DEG-associated neurotoxicity. Further work characterizing the pathophysiology of DEG-associated neurotoxicity and the role of traditional toxic alcohol therapies such as fomepizole and hemodialysis is needed.

  9. Expression and methylation of circulating microRNA-510 in essential hypertension.

    PubMed

    Krishnan, Ramalingam; Mani, Panagal; Sivakumar, Pethanen; Gopinath, Vincent; Sekar, Durairaj

    2017-04-01

    Hypertension (HTN) is one of the most common emerging disease in developing countries. It alters endothelial cell structure and function, resulting in several diseases, such as cardiovascular disease, peripheral vasculopathy, cerebrovascular disease and nephropathy. Although much progress has been made in researching HTN in recent years, early diagnosis and treatment of HTN are not yet satisfactory, and progression control/treatment is still poor. MicroRNAs are well-known regulators of the physiological and developmental processes of HTN. Our results revealed that miR-510 was upregulated in blood samples from HTN patients, whereas no significant differences were observed in the control samples. Methylation analyses corroborated the miR-510 upregulation in patient samples. These results suggested that miR-510 can be used as a novel biomarker for diagnosis and as a new therapeutic target for HTN.

  10. Influence of pollution control on lead inhalation bioaccessibility in PM2.5: A case study of 2014 Youth Olympic Games in Nanjing.

    PubMed

    Li, Shi-Wei; Li, Hong-Bo; Luo, Jun; Li, Hui-Ming; Qian, Xin; Liu, Miao-Miao; Bi, Jun; Cui, Xin-Yi; Ma, Lena Q

    2016-09-01

    Pollution controls were implemented to improve the air quality for the 2014 Youth Olympic Games (YOG) in Nanjing. To investigate the influence of pollution control on Pb inhalation bioaccessibility in PM2.5, samples were collected before, during, and after YOG. The objectives were to identify Pb sources in PM2.5 using stable isotope fingerprinting technique and compare Pb inhalation bioaccessibility in PM2.5 using two simulated lung fluids. While artificial lysosomal fluid (ALF) simulates interstitial fluid at pH 7.4, Gamble's solution simulates fluid in alveolar macrophages at pH 4.5. The Pb concentration in PM2.5 samples during YOG (88.2ngm(-3)) was 44-48% lower than that in non-YOG samples. Based on stable Pb isotope ratios, Pb in YOG samples was mainly from coal combustion while Pb in non-YOG samples was from coal combustion and smelting activities. While Pb bioaccessibility in YOG samples was lower than those in non-YOG samples (59-79% vs. 55-87%) by ALF, it was higher than those in non-YOG samples (11-29% vs. 5.3-21%) based on Gamble's solution, attributing to the lower pH and organic acids in ALF. Different Pb bioaccessibility in PM2.5 between samples resulted from changes in Pb species due to pollution control. PbSO4 was the main Pb species in PM2.5 from coal combustion, which was less soluble in ALF than PbO from smelting activities, but more soluble in Gamble's solution. This study showed it is important to consider Pb bioaccessibility during pollution control as source control not only reduced Pb contamination in PM2.5 but also influenced Pb bioaccessibility. Published by Elsevier Ltd.

  11. Measurements of induced radioactivity in some LDEF samples

    NASA Technical Reports Server (NTRS)

    Moss, C. E.; Reedy, R. C.

    1992-01-01

    Twenty-six stainless steel trunnion samples, five aluminum end support retainer plate samples, two aluminum keel plate samples, and two titanium clips were analyzed. The shielded high purity germanium detectors used had efficiencies of 33, 54, and 80 percent at 1332 keV. Detector efficiencies as a function of energy and corrections for self-absorption in the samples were determined with calibrated sources and unactivated control samples. Several measurements were made on most samples. In the trunnion samples, Mn-54 and Co-57 were seen and limits were obtained for other isotopes. The results agree well with 1-D activation calculations for an anisotropic trapped proton model. In the aluminum and titanium samples, Na-22 was detected. Other results are presented.

  12. Measurements of induced radioactivity in some LDEF samples

    NASA Technical Reports Server (NTRS)

    Moss, C. E.; Reedy, R. C.

    1991-01-01

    Twenty-six stainless steel trunnion samples, five aluminum end support retainer plate samples, two aluminum keel plate samples, and two titanium clips were analyzed. The shielded high purity germanium detectors used had efficiencies of 33, 54, and 80 pcts. at 1332 keV. Detector efficiencies as a function of energy and corrections for self absorption in the samples were determined with calibrated sources, unactivated control samples, and calculations. Several measurements were made on most samples. In the trunnion samples, Mn-54 and Co-57 were seen and limits were obtained for other isotopes. The results agree well with 1-D activation calculations for an anisotropic trapped proton model. In the aluminum samples, Na-22 and Be-7 were seen. Other results are presented.

  13. Age differences in coping and locus of control: a study of managerial stress in Hong Kong.

    PubMed

    Siu, O; Cooper, C L; Spector, P E; Donald, I

    2001-12-01

    The present study involved data collection from 3 samples of Hong Kong managers to examine mechanisms by which age would relate to work well-being. A total of 634 managers was drawn by random sampling and purposive sampling methods. The results showed that age was positively related to well-being (job satisfaction and mental well-being). Furthermore, older managers reported fewer sources of stress, better coping, and a more internal locus of control. Multiple regression analyses suggested that the relations of age with 2 well-being indicators can be attributed to various combinations of coping, work locus of control, sources of stress, managerial level, and organizational tenure.

  14. Factors of quality of financial report of local government in Indonesia

    NASA Astrophysics Data System (ADS)

    Muda, Iskandar; Haris Harahap, Abdul; Erlina; Ginting, Syafruddin; Maksum, Azhar; Abubakar, Erwin

    2018-03-01

    The purpose of this research is to find out whether the Accounting Information System and Internal Control in Local Revenue Office to the affect the Quality of Financial Report of Local Government. The sampling was conducted by using simple random sampling method in which the sample was determined without considering strata. The data research was conducted by distributing the questionnaires. The results showed that the degree of Accounting Information System and Internal Control simultaneously affect the Quality of Financial Report of Local Government. However, partially, Partially, accounting information system influence to the quality of financial report of local government and the internal control does not affect the quality of financial report.

  15. Neurocognitive performance in family-based and case-control studies of schizophrenia

    PubMed Central

    Gur, Ruben C.; Braff, David L.; Calkins, Monica E.; Dobie, Dorcas J.; Freedman, Robert; Green, Michael F.; Greenwood, Tiffany A.; Lazzeroni, Laura C.; Light, Gregory A.; Nuechterlein, Keith H.; Olincy, Ann; Radant, Allen D.; Seidman, Larry J.; Siever, Larry J.; Silverman, Jeremy M.; Sprock, Joyce; Stone, William S.; Sugar, Catherine A.; Swerdlow, Neal R.; Tsuang, Debby W.; Tsuang, Ming T.; Turetsky, Bruce I.; Gur, Raquel E.

    2014-01-01

    Background Neurocognitive deficits in schizophrenia (SZ) are established and the Consortium on the Genetics of Schizophrenia (COGS) investigated such measures as endophenotypes in family-based (COGS-1) and case-control (COGS-2) studies. By requiring family participation, family-based sampling may result in samples that vary demographically and perform better on neurocognitive measures. Methods The Penn computerized neurocognitive battery (CNB) evaluates accuracy and speed of performance for several domains and was administered across sites in COGS-1 and COGS-2. Most tests were included in both studies. COGS-1 included 328 patients with SZ and 497 healthy comparison subjects (HCS) and COGS-2 included 1195 patients and 1009 HCS. Results Demographically, COGS-1 participants were younger, more educated, with more educated parents and higher estimated IQ compared to COGS-2 participants. After controlling for demographics, the two samples produced very similar performance profiles compared to their respective controls. As expected, performance was better and with smaller effect sizes compared to controls in COGS-1 relative to COGS-2. Better performance was most pronounced for spatial processing while emotion identification had large effect sizes for both accuracy and speed in both samples. Performance was positively correlated with functioning and negatively with negative and positive symptoms in both samples, but correlations were attenuated in COGS-2, especially with positive symptoms. Conclusions Patients ascertained through family-based design have more favorable demographics and better performance on some neurocognitive domains. Thus, studies that use case-control ascertainment may tap into populations with more severe forms of illness that are exposed to less favorable factors compared to those ascertained with family-based designs. PMID:25432636

  16. Patterning of alloy precipitation through external pressure

    NASA Astrophysics Data System (ADS)

    Franklin, Jack A.

    Due to the nature of their microstructure, alloyed components have the benefit of meeting specific design goals across a wide range of electrical, thermal, and mechanical properties. In general by selecting the correct alloy system and applying a proper heat treatment it is possible to create a metallic sample whose properties achieve a unique set of design requirements. This dissertation presents an innovative processing technique intended to control both the location of formation and the growth rates of precipitates within metallic alloys in order to create multiple patterned areas of unique microstructure within a single sample. Specific experimental results for the Al-Cu alloy system will be shown. The control over precipitation is achieved by altering the conventional heat treatment process with an external surface load applied to selected locations during the quench and anneal. It is shown that the applied pressures affect both the rate and directionality of the atomic diffusion in regions close to the loaded surfaces. The control over growth rates is achieved by altering the enthalpic energy required for successful diffusion between lattice sites. Changes in the local chemical free energy required to direct the diffusion of atoms are established by introducing a non-uniform elastic strain energy field within the samples created by the patterned surface pressures. Either diffusion rates or atomic mobility can be selected as the dominating control process by varying the quench rate; with slower quenches having greater control over the mobility of the alloying elements. Results have shown control of Al2Cu precipitation over 100 microns on mechanically polished surfaces. Further experimental considerations presented will address consistency across sample ensembles. This includes repeatable pressure loading conditions and the chemical interaction between any furnace environments and both the alloy sample and metallic pressure loading devices.

  17. Investigation Into Shelf Life of Fresh Dates and Pistachios in a Package Modified With Nano-Silver

    PubMed Central

    Mousavi, Fateme Peyro; Pour, Hasan Hashemi; Nasab, Amir Heidari; Rajabalipour, Ali A.; Barouni, Mohsen

    2016-01-01

    Aims: The aim of this study was to apply polymer films containing silver nanoparticles as a new method for increasing the shelf life and preserving the quality of export/commercial products of Kerman Province and determine the ideal temperature for preserving these products. Methods: After preparing nano-composite films containing silver nanoparticles (3% and 5% by weight), Mazafati dates were packed in them and stored with their control samples under four temperatures. In the second series, the films were filled with fresh pistachios and stored at four temperatures. In date samples, after 2, 7, 21 and 53 days of storing the samples were examined under the certified test of Iran Institute of Industrial Standard for Dates, which includes pH, TSS, acidity and reducing sugars tests. In pistachio samples the color values and market-friendly quality were evaluated after 1, 2, 3, 6, 7 and 8 days of storage. Results: In date samples, the pH value decreased with increasing acidity in 3 and 5 wt% of nano-silver and their control samples. In addition, in 5 wt% samples the acidity was higher than that in 3% samples, with pH being lower in the controls at almost all the intervals. Furthermore, pH values in 5% samples were higher in comparison with 3 wt% samples and controls. The amount of reducing sugars in the control samples was lower than those in 3 and 5 wt% samples. In relation to pistachio samples, the damage over time was greater in sample stored under higher temperatures. Conclusion: The maximum shelf life of the dates packaged in 5 wt% of silver nano-powder was 53 days and the best temperature to store samples was determined at 4°C. Packages containing nano-silver increased shelf life of fresh pistachios, with the best temperatures being 25°C and 0°C. PMID:26652097

  18. Polychlorinated Biphenyls in suspended-sediment samples from outfalls to Meandering Road Creek at Air Force Plant 4, Fort Worth, Texas, 2003-08

    USGS Publications Warehouse

    Braun, Christopher L.; Wilson, Jennifer T.

    2010-01-01

    Meandering Road Creek is an intermittent stream and tributary to Lake Worth, a reservoir on the West Fork Trinity River on the western edge of Fort Worth, Texas. U.S. Air Force Plant 4 (AFP4) is on the eastern shore of Woods Inlet, an arm of Lake Worth. Meandering Road Creek gains inflow from several stormwater outfalls as it flows across AFP4. Several studies have characterized polychlorinated biphenyls (PCBs) in the water and sediments of Lake Worth and Meandering Road Creek; sources of PCBs are believed to originate primarily from AFP4. Two previous U.S. Geological Survey (USGS) reports documented elevated PCB concentrations in surficial sediment samples from Woods Inlet relative to concentrations in surficial sediment samples from other parts of Lake Worth. The second of these two previous reports also identified some of the sources of PCBs to Lake Worth. These reports were followed by a third USGS report that documented the extent of PCB contamination in Meandering Road Creek and Woods Inlet and identified runoff from outfalls 4 and 5 at AFP4 as prominent sources of these PCBs. This report describes the results of a fourth study by the USGS, in cooperation with the Lockheed Martin Corporation, to investigate PCBs in suspended-sediment samples in storm runoff from outfalls 4 and 5 at AFP4 following the implementation of engineering controls designed to potentially alleviate PCB contamination in the drainage areas of these outfalls. Suspended-sediment samples collected from outfalls 4 and 5 during storms on March 2 and November 10, 2008, were analyzed for selected PCBs. Sums of concentrations of 18 reported PCB congeners (Sigma PCBc) in suspended-sediment samples collected before and after implementation of engineering controls are compared. At both outfalls, the Sigma PCBc before engineering controls was higher than the Sigma PCBc after engineering controls. The Sigma PCBc in suspended-sediment samples collected at AFP4 before and after implementation of engineering controls also is compared to the threshold effect concentration (TEC), the concentration below which adverse effects to benthic biota rarely occur. Sigma PCBc exceeded the TEC for 75 percent of the samples collected at outfall 4 and 67 percent of the samples collected at outfall 5 before the implementation of engineering controls. Sigma PCBc did not exceed the TEC in samples collected at either outfall 4 or outfall 5 after the implementation of engineering controls. The relative prominence of 10 selected PCB congeners was evaluated by graphical analysis of ratios of individual concentrations of the 10 PCB congeners to the sum of these PCB congeners. An overall decrease in concentrations of PCB congeners at outfalls 4 and 5 after implementation of engineering controls, as well as a shift in prominence from lighter, less chlorinated congeners to a heavier, more chlorinated congener might have resulted from the implementation of engineering controls. Because of the small number of samples collected and lack of runoff and precipitation data to evaluate comparability of sampling conditions before and after implementation of engineering controls, all conclusions are preliminary.

  19. The Effect of Learning Based on Technology Model and Assessment Technique toward Thermodynamic Learning Achievement

    NASA Astrophysics Data System (ADS)

    Makahinda, T.

    2018-02-01

    The purpose of this research is to find out the effect of learning model based on technology and assessment technique toward thermodynamic achievement by controlling students intelligence. This research is an experimental research. The sample is taken through cluster random sampling with the total respondent of 80 students. The result of the research shows that the result of learning of thermodynamics of students who taught the learning model of environmental utilization is higher than the learning result of student thermodynamics taught by simulation animation, after controlling student intelligence. There is influence of student interaction, and the subject between models of technology-based learning with assessment technique to student learning result of Thermodynamics, after controlling student intelligence. Based on the finding in the lecture then should be used a thermodynamic model of the learning environment with the use of project assessment technique.

  20. Acoustic Sample Deposition MALDI-MS (ASD-MALDI-MS): A Novel Process Flow for Quality Control Screening of Compound Libraries.

    PubMed

    Chin, Jefferson; Wood, Elizabeth; Peters, Grace S; Drexler, Dieter M

    2016-02-01

    In the early stages of drug discovery, high-throughput screening (HTS) of compound libraries against pharmaceutical targets is a common method to identify potential lead molecules. For these HTS campaigns to be efficient and successful, continuous quality control of the compound collection is necessary and crucial. However, the large number of compound samples and the limited sample amount pose unique challenges. Presented here is a proof-of-concept study for a novel process flow for the quality control screening of small-molecule compound libraries that consumes only minimal amounts of samples and affords compound-specific molecular data. This process employs an acoustic sample deposition (ASD) technique for the offline sample preparation by depositing nanoliter volumes in an array format onto microscope glass slides followed by matrix-assisted laser desorption/ionization mass spectrometric (MALDI-MS) analysis. An initial study of a 384-compound array employing the ASD-MALDI-MS workflow resulted in a 75% first-pass positive identification rate with an analysis time of <1 s per sample. © 2015 Society for Laboratory Automation and Screening.

  1. LabVIEW-based control software for para-hydrogen induced polarization instrumentation.

    PubMed

    Agraz, Jose; Grunfeld, Alexander; Li, Debiao; Cunningham, Karl; Willey, Cindy; Pozos, Robert; Wagner, Shawn

    2014-04-01

    The elucidation of cell metabolic mechanisms is the modern underpinning of the diagnosis, treatment, and in some cases the prevention of disease. Para-Hydrogen induced polarization (PHIP) enhances magnetic resonance imaging (MRI) signals over 10,000 fold, allowing for the MRI of cell metabolic mechanisms. This signal enhancement is the result of hyperpolarizing endogenous substances used as contrast agents during imaging. PHIP instrumentation hyperpolarizes Carbon-13 ((13)C) based substances using a process requiring control of a number of factors: chemical reaction timing, gas flow, monitoring of a static magnetic field (Bo), radio frequency (RF) irradiation timing, reaction temperature, and gas pressures. Current PHIP instruments manually control the hyperpolarization process resulting in the lack of the precise control of factors listed above, resulting in non-reproducible results. We discuss the design and implementation of a LabVIEW based computer program that automatically and precisely controls the delivery and manipulation of gases and samples, monitoring gas pressures, environmental temperature, and RF sample irradiation. We show that the automated control over the hyperpolarization process results in the hyperpolarization of hydroxyethylpropionate. The implementation of this software provides the fast prototyping of PHIP instrumentation for the evaluation of a myriad of (13)C based endogenous contrast agents used in molecular imaging.

  2. LabVIEW-based control software for para-hydrogen induced polarization instrumentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agraz, Jose, E-mail: joseagraz@ucla.edu; Grunfeld, Alexander; Li, Debiao

    2014-04-15

    The elucidation of cell metabolic mechanisms is the modern underpinning of the diagnosis, treatment, and in some cases the prevention of disease. Para-Hydrogen induced polarization (PHIP) enhances magnetic resonance imaging (MRI) signals over 10 000 fold, allowing for the MRI of cell metabolic mechanisms. This signal enhancement is the result of hyperpolarizing endogenous substances used as contrast agents during imaging. PHIP instrumentation hyperpolarizes Carbon-13 ({sup 13}C) based substances using a process requiring control of a number of factors: chemical reaction timing, gas flow, monitoring of a static magnetic field (B{sub o}), radio frequency (RF) irradiation timing, reaction temperature, and gas pressures.more » Current PHIP instruments manually control the hyperpolarization process resulting in the lack of the precise control of factors listed above, resulting in non-reproducible results. We discuss the design and implementation of a LabVIEW based computer program that automatically and precisely controls the delivery and manipulation of gases and samples, monitoring gas pressures, environmental temperature, and RF sample irradiation. We show that the automated control over the hyperpolarization process results in the hyperpolarization of hydroxyethylpropionate. The implementation of this software provides the fast prototyping of PHIP instrumentation for the evaluation of a myriad of {sup 13}C based endogenous contrast agents used in molecular imaging.« less

  3. Quality-control results for ground-water and surface-water data, Sacramento River Basin, California, National Water-Quality Assessment, 1996-1998

    USGS Publications Warehouse

    Munday, Cathy; Domagalski, Joseph L.

    2003-01-01

    Evaluating the extent that bias and variability affect the interpretation of ground- and surface-water data is necessary to meet the objectives of the National Water-Quality Assessment (NAWQA) Program. Quality-control samples used to evaluate the bias and variability include annual equipment blanks, field blanks, field matrix spikes, surrogates, and replicates. This report contains quality-control results for the constituents critical to the ground- and surface-water components of the Sacramento River Basin study unit of the NAWQA Program. A critical constituent is one that was detected frequently (more than 50 percent of the time in blank samples), was detected at amounts exceeding water-quality standards or goals, or was important for the interpretation of water-quality data. Quality-control samples were collected along with ground- and surface-water samples during the high intensity phase (cycle 1) of the Sacramento River Basin NAWQA beginning early in 1996 and ending in 1998. Ground-water field blanks indicated contamination of varying levels of significance when compared with concentrations detected in environmental ground-water samples for ammonia, dissolved organic carbon, aluminum, and copper. Concentrations of aluminum in surface-water field blanks were significant when compared with environmental samples. Field blank samples collected for pesticide and volatile organic compound analyses revealed no contamination in either ground- or surface-water samples that would effect the interpretation of environmental data, with the possible exception of the volatile organic compound trichloromethane (chloroform) in ground water. Replicate samples for ground water and surface water indicate that variability resulting from sample collection, processing, and analysis was generally low. Some of the larger maximum relative percentage differences calculated for replicate samples occurred between samples having lowest absolute concentration differences and(or) values near the reporting limit. Surrogate recoveries for pesticides analyzed by gas chromatography/mass spectrometry (GC/MS), pesticides analyzed by high performance liquid chromatography (HPLC), and volatile organic compounds in ground- and surface-water samples were within the acceptable limits of 70 to 130 percent and median recovery values between 82 and 113 percent. The recovery percentages for surrogate compounds analyzed by HPLC had the highest standard deviation, 20 percent for ground-water samples and 16 percent for surface-water samples, and the lowest median values, 82 percent for ground-water samples and 91 percent for surface-water samples. Results were consistent with the recovery results described for the analytical methods. Field matrix spike recoveries for pesticide compounds analyzed using GC/MS in ground- and surface-water samples were comparable with published recovery data. Recoveries of carbofuran, a critical constituent in ground- and surface-water studies, and desethyl atrazine, a critical constituent in the ground-water study, could not be calculated because of problems with the analytical method. Recoveries of pesticides analyzed using HPLC in ground- and surface-water samples were generally low and comparable with published recovery data. Other methodological problems for HPLC analytes included nondetection of the spike compounds and estimated values of spike concentrations. Recovery of field matrix spikes for volatile organic compounds generally were within the acceptable range, 70 and 130 percent for both ground- and surface-water samples, and median recoveries from 62 to 127 percent. High or low recoveries could be related to errors in the field, such as double spiking or using spike solution past its expiration date, rather than problems during analysis. The methodological changes in the field spike protocol during the course of the Sacramento River Basin study, which included decreasing the amount of spike solu

  4. Evaluation of the technical performance of novel holotranscobalamin (holoTC) assays in a multicenter European demonstration project.

    PubMed

    Morkbak, Anne L; Heimdal, Randi M; Emmens, Kathleen; Molloy, Anne; Hvas, Anne-Mette; Schneede, Joern; Clarke, Robert; Scott, John M; Ueland, Per M; Nexo, Ebba

    2005-01-01

    A commercially available holotranscobalamin (holo-TC) radioimmunoassay (RIA) (Axis-Shield, Dundee, Scotland) was evaluated in four laboratories and compared with a holoTC ELISA run in one laboratory. The performance of the holoTC RIA assay was comparable in three of the four participating laboratories. The results from these three laboratories, involving at least 20 initial runs of "low", "medium" and "high" serum-based controls (mean holoTC concentrations 34, 60 and 110 pmol/L, respectively) yielded an intra-laboratory imprecision of 6-10%. No systematic inter-laboratory deviations were observed on runs involving 72 patient samples (holoTC concentration range 10-160 pmol/L). A fourth laboratory demonstrated higher assay imprecision for control samples and systematic deviation of results for the patient samples. Measurement of holoTC by ELISA showed an imprecision of 4-5%, and slightly higher mean values for the controls (mean holoTC concentrations 40, 70 and 114 pmol/L, respectively). Comparable results were obtained for the patient samples. The long-term intra-laboratory imprecision was 12% for the holoTC RIA and 6% for the ELISA. In conclusion, it would be prudent to check the calibration and precision prior to starting to use these holoTC assays in research or clinical practice. The results obtained using the holoTC RIA were similar to those obtained using the holoTC ELISA assay.

  5. Gross Motor Development in Children Aged 3-5 Years, United States 2012.

    PubMed

    Kit, Brian K; Akinbami, Lara J; Isfahani, Neda Sarafrazi; Ulrich, Dale A

    2017-07-01

    Objective Gross motor development in early childhood is important in fostering greater interaction with the environment. The purpose of this study is to describe gross motor skills among US children aged 3-5 years using the Test of Gross Motor Development (TGMD-2). Methods We used 2012 NHANES National Youth Fitness Survey (NNYFS) data, which included TGMD-2 scores obtained according to an established protocol. Outcome measures included locomotor and object control raw and age-standardized scores. Means and standard errors were calculated for demographic and weight status with SUDAAN using sample weights to calculate nationally representative estimates, and survey design variables to account for the complex sampling methods. Results The sample included 339 children aged 3-5 years. As expected, locomotor and object control raw scores increased with age. Overall mean standardized scores for locomotor and object control were similar to the mean value previously determined using a normative sample. Girls had a higher mean locomotor, but not mean object control, standardized score than boys (p < 0.05). However, the mean locomotor standardized scores for both boys and girls fell into the range categorized as "average." There were no other differences by age, race/Hispanic origin, weight status, or income in either of the subtest standardized scores (p > 0.05). Conclusions In a nationally representative sample of US children aged 3-5 years, TGMD-2 mean locomotor and object control standardized scores were similar to the established mean. These results suggest that standardized gross motor development among young children generally did not differ by demographic or weight status.

  6. Hydraulically controlled discrete sampling from open boreholes

    USGS Publications Warehouse

    Harte, Philip T.

    2013-01-01

    Groundwater sampling from open boreholes in fractured-rock aquifers is particularly challenging because of mixing and dilution of fluid within the borehole from multiple fractures. This note presents an alternative to traditional sampling in open boreholes with packer assemblies. The alternative system called ZONFLO (zonal flow) is based on hydraulic control of borehole flow conditions. Fluid from discrete fractures zones are hydraulically isolated allowing for the collection of representative samples. In rough-faced open boreholes and formations with less competent rock, hydraulic containment may offer an attractive alternative to physical containment with packers. Preliminary test results indicate a discrete zone can be effectively hydraulically isolated from other zones within a borehole for the purpose of groundwater sampling using this new method.

  7. Method of Analysis by the U.S. Geological Survey California District Sacramento Laboratory?Determination of Trihalomethane Formation Potential, Method Validation, and Quality-Control Practices

    USGS Publications Warehouse

    Crepeau, Kathryn L.; Fram, Miranda S.; Bush, Noel

    2004-01-01

    An analytical method for the determination of the trihalomethane formation potential of water samples has been developed. The trihalomethane formation potential is measured by dosing samples with chlorine under specified conditions of pH, temperature, incubation time, darkness, and residual-free chlorine, and then analyzing the resulting trihalomethanes by purge and trap/gas chromatography equipped with an electron capture detector. Detailed explanations of the method and quality-control practices are provided. Method validation experiments showed that the trihalomethane formation potential varies as a function of time between sample collection and analysis, residual-free chlorine concentration, method of sample dilution, and the concentration of bromide in the sample.

  8. A Systematic Review of Surgical Randomized Controlled Trials: Part 2. Funding Source, Conflict of Interest, and Sample Size in Plastic Surgery.

    PubMed

    Voineskos, Sophocles H; Coroneos, Christopher J; Ziolkowski, Natalia I; Kaur, Manraj N; Banfield, Laura; Meade, Maureen O; Chung, Kevin C; Thoma, Achilleas; Bhandari, Mohit

    2016-02-01

    The authors examined industry support, conflict of interest, and sample size in plastic surgery randomized controlled trials that compared surgical interventions. They hypothesized that industry-funded trials demonstrate statistically significant outcomes more often, and randomized controlled trials with small sample sizes report statistically significant results more frequently. An electronic search identified randomized controlled trials published between 2000 and 2013. Independent reviewers assessed manuscripts and performed data extraction. Funding source, conflict of interest, primary outcome direction, and sample size were examined. Chi-squared and independent-samples t tests were used in the analysis. The search identified 173 randomized controlled trials, of which 100 (58 percent) did not acknowledge funding status. A relationship between funding source and trial outcome direction was not observed. Both funding status and conflict of interest reporting improved over time. Only 24 percent (six of 25) of industry-funded randomized controlled trials reported authors to have independent control of data and manuscript contents. The mean number of patients randomized was 73 per trial (median, 43, minimum, 3, maximum, 936). Small trials were not found to be positive more often than large trials (p = 0.87). Randomized controlled trials with small sample size were common; however, this provides great opportunity for the field to engage in further collaboration and produce larger, more definitive trials. Reporting of trial funding and conflict of interest is historically poor, but it greatly improved over the study period. Underreporting at author and journal levels remains a limitation when assessing the relationship between funding source and trial outcomes. Improved reporting and manuscript control should be goals that both authors and journals can actively achieve.

  9. 40 CFR 761.316 - Interpreting PCB concentration measurements resulting from this sampling scheme.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT POLYCHLORINATED BIPHENYLS (PCBs) MANUFACTURING, PROCESSING, DISTRIBUTION IN COMMERCE, AND USE PROHIBITIONS Sampling Non-Porous Surfaces for... equivalent measurement of micrograms per 100 cm2. ...

  10. 40 CFR 761.316 - Interpreting PCB concentration measurements resulting from this sampling scheme.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT POLYCHLORINATED BIPHENYLS (PCBs) MANUFACTURING, PROCESSING, DISTRIBUTION IN COMMERCE, AND USE PROHIBITIONS Sampling Non-Porous Surfaces for... equivalent measurement of micrograms per 100 cm2. ...

  11. 40 CFR 761.316 - Interpreting PCB concentration measurements resulting from this sampling scheme.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT POLYCHLORINATED BIPHENYLS (PCBs) MANUFACTURING, PROCESSING, DISTRIBUTION IN COMMERCE, AND USE PROHIBITIONS Sampling Non-Porous Surfaces for... equivalent measurement of micrograms per 100 cm2. ...

  12. 40 CFR 761.316 - Interpreting PCB concentration measurements resulting from this sampling scheme.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT POLYCHLORINATED BIPHENYLS (PCBs) MANUFACTURING, PROCESSING, DISTRIBUTION IN COMMERCE, AND USE PROHIBITIONS Sampling Non-Porous Surfaces for... equivalent measurement of micrograms per 100 cm2. ...

  13. Detection of anabolic androgenic steroid abuse in doping control using mammalian reporter gene bioassays.

    PubMed

    Houtman, Corine J; Sterk, Saskia S; van de Heijning, Monique P M; Brouwer, Abraham; Stephany, Rainer W; van der Burg, Bart; Sonneveld, Edwin

    2009-04-01

    Anabolic androgenic steroids (AAS) are a class of steroid hormones related to the male hormone testosterone. They are frequently detected as drugs in sport doping control. Being similar to or derived from natural male hormones, AAS share the activation of the androgen receptor (AR) as common mechanism of action. The mammalian androgen responsive reporter gene assay (AR CALUX bioassay), measuring compounds interacting with the AR can be used for the analysis of AAS without the necessity of knowing their chemical structure beforehand, whereas current chemical-analytical approaches may have difficulty in detecting compounds with unknown structures, such as designer steroids. This study demonstrated that AAS prohibited in sports and potential designer AAS can be detected with this AR reporter gene assay, but that also additional steroid activities of AAS could be found using additional mammalian bioassays for other types of steroid hormones. Mixtures of AAS were found to behave additively in the AR reporter gene assay showing that it is possible to use this method for complex mixtures as are found in doping control samples, including mixtures that are a result of multi drug use. To test if mammalian reporter gene assays could be used for the detection of AAS in urine samples, background steroidal activities were measured. AAS-spiked urine samples, mimicking doping positive samples, showed significantly higher androgenic activities than unspiked samples. GC-MS analysis of endogenous androgens and AR reporter gene assay analysis of urine samples showed how a combined chemical-analytical and bioassay approach can be used to identify samples containing AAS. The results indicate that the AR reporter gene assay, in addition to chemical-analytical methods, can be a valuable tool for the analysis of AAS for doping control purposes.

  14. Evaluation of chromium, cobalt and manganese in biological samples (scalp hair, blood, and urine) of Pakistani viral hepatitis (A-E) patients and controls.

    PubMed

    Afridi, Hassan Imran; Kazi, Tasneem Gul; Kazi, Naveed; Naeemullah; Arain, Sadaf Sadia; Brahman, Kapil Dev; Wadhwa, Sham Kumar

    2013-01-01

    The aim of the present study was to compare the level of chromium (Cr), cobalt (Co), and manganese (Mn) in biological samples (blood, urine, and scalp hair) of patients suffering from different types of viral hepatitis (A, B, C, D, and E; n = 521) of both genders, ages ranging from 31 - 45 years. For comparative study, 255 age-matched control subjects of both genders residing in the same city were selected as referents. The digests of all biological samples were analysed for Cr, Co, and Mn by electrothermal atomic absorption spectrometry (ETAAS). The validity and accuracy of the methodology was checked by using certified reference materials (CRMs) and compared with those values obtained by conventional wet acid digestion method on same CRMs. The results of this study showed that the mean values of Cr, Co, and Mn were higher in blood and scalp hair samples of hepatitis patients than in age-matched control subjects. The urinary levels of these elements were found to be higher in the hepatitis patients than in the age-matched healthy controls (p <0.001). These results are consistent with literature-reported data, confirming that the overload of these trace elements can directly cause lipid peroxidation and eventually hepatic damage.

  15. How reliable are odour assessments?

    PubMed

    Bokowa, A; Beukes, J A

    2012-01-01

    This paper will demonstrate the differences found in odour test results, when odour sampling is performed at the same sources by two different consultants. By examining two case studies, this paper will highlight that the difference between the results can be significant. Both studies are based on odour sampling programs determining the odour removal efficiency of odour control units installed at two different facilities: a pet food facility and an oil/grease recycling facility. The first study is based on odour measurements at the inlet and outlet of the unit installed by Applied Plasma Physics AS at the pet food facility. Odour assessments were performed by two separate consultants at the same time. The second study is based on testing of the odour removal effectiveness of two units: a scrubber and a biofilter at an oil/grease recycling facility. During this study two odour sampling programs were performed by two consultants at different times, but under the same process conditions. This paper will show how varying results can play a role in choosing the adequate odour control technologies. The final results suggest that although, an odour control unit may appear to be insufficient, it actually is successful at removing the odours.

  16. Estimating removal rates of bacteria from poultry carcasses using two whole-carcass rinse volumes

    USDA-ARS?s Scientific Manuscript database

    Rinse sampling is a common method for determining the level of microbial contamination on poultry carcasses. One of the advantages of rinse sampling, over other carcass sampling methods, is that the results can be used for both process control applications and to estimate the total microbial level o...

  17. Digital implementation of the TF30-P-3 turbofan engine control

    NASA Technical Reports Server (NTRS)

    Cwynar, D. S.; Batterton, P. G.

    1975-01-01

    The standard hydromechanical control modes for TF30-P-3 engine were implemented on a digital process control computer. Programming methods are described, and a method is presented to solve stability problems associated with fast response dynamic loops contained within the exhaust nozzle control. A modification of the exhaust nozzle control to provide for either velocity or position servoactuation systems is discussed. Transient response of the digital control was evaluated by tests on a real time hybrid simulation of the TF30-P-3 engine. It is shown that the deadtime produced by the calculation time delay between sampling and final output is more significant to transient response than the effects associated with sampling rate alone. For the main fuel control, extended update and calculation times resulted in a lengthened transient response to throttle bursts from idle to intermediate with an increase in high pressure compressor stall margin. Extremely long update intervals of 250 msec could be achieved without instability. Update extension for the exhaust nozzle control resulted in a delayed response of the afterburner light-off detector and exhaust nozzle overshoot with resulting fan oversuppression. Long update times of 150 msec caused failure of the control due to a false indication by the blowout detector.

  18. Disposable Collection Kit for Rapid and Reliable Collection of Saliva

    PubMed Central

    Yamaguchi, Masaki; Tezuka, Yuki; Takeda, Kazunori; Shetty, Vivek

    2015-01-01

    Objectives To describe and evaluate disposable saliva collection kit for rapid, reliable, and reproducible collection of saliva samples. Methods The saliva collection kit comprised of a saliva absorbent swab and an extractor unit was used to retrieve whole saliva samples from 10 subjects. The accuracy and precision of the extracted volumes (3, 10, and 30 μl) were compared to similar volumes drawn from control samples obtained by passive drool. Additionally, the impact of kit collection method on subsequent immunoassay results was verified by assessing salivary cortisol levels in the samples and comparing them to controls. Results The recovered volumes for the whole saliva samples were 3.85 ± 0.28, 10.79 ± 0.95, and 31.18 ± 1.72 μl, respectively (CV = 8.76%) and 2.91 ± 0.19, 9.75 ± 0.43, and 29.64 ± 0.91 μl, respectively, (CV = 6.36%) for the controls. There was a close correspondence between the salivary cortisol levels from the saliva samples obtained by the collection kit and the controls (R2 > 0.96). Conclusions The disposable saliva collection kit allows accurate and repeatable collection of fixed amounts of whole saliva and does not interfere with subsequent measurements of salivary cortisol. The simple collection process, lack of elaborate specimen recovery steps, and the short turnaround time (<3 min) should render the kit attractive to test subjects and researchers alike. Am. J. Hum. Biol. 27:720–723, 2015. © 2015 The Authors American Journal of Human Biology Published by Wiley Periodicals, Inc. PMID:25754371

  19. Model-Based Adaptive Event-Triggered Control of Strict-Feedback Nonlinear Systems.

    PubMed

    Li, Yuan-Xin; Yang, Guang-Hong

    2018-04-01

    This paper is concerned with the adaptive event-triggered control problem of nonlinear continuous-time systems in strict-feedback form. By using the event-sampled neural network (NN) to approximate the unknown nonlinear function, an adaptive model and an associated event-triggered controller are designed by exploiting the backstepping method. In the proposed method, the feedback signals and the NN weights are aperiodically updated only when the event-triggered condition is violated. A positive lower bound on the minimum intersample time is guaranteed to avoid accumulation point. The closed-loop stability of the resulting nonlinear impulsive dynamical system is rigorously proved via Lyapunov analysis under an adaptive event sampling condition. In comparing with the traditional adaptive backstepping design with a fixed sample period, the event-triggered method samples the state and updates the NN weights only when it is necessary. Therefore, the number of transmissions can be significantly reduced. Finally, two simulation examples are presented to show the effectiveness of the proposed control method.

  20. Diagenetic and compositional controls of wettability in siliceous sedimentary rocks, Monterey Formation, California

    NASA Astrophysics Data System (ADS)

    Hill, Kristina M.

    Modified imbibition tests were performed on 69 subsurface samples from Monterey Formation reservoirs in the San Joaquin Valley to measure wettability variation as a result of composition and silica phase change. Contact angle tests were also performed on 6 chert samples from outcrop and 3 nearly pure mineral samples. Understanding wettability is important because it is a key factor in reservoir fluid distribution and movement, and its significance rises as porosity and permeability decrease and fluid interactions with reservoir grain surface area increase. Although the low permeability siliceous reservoirs of the Monterey Formation are economically important and prolific, a greater understanding of factors that alter their wettability will help better develop them. Imbibition results revealed a strong trend of decreased wettability to oil with increased detrital content in opal-CT phase samples. Opal-A phase samples exhibited less wettability to oil than both opal-CT and quartz phase samples of similar detrital content. Subsurface reservoir samples from 3 oil fields were crushed to eliminate the effect of capillary pressure and cleansed of hydrocarbons to eliminate wettability alterations by asphaltene, then pressed into discs of controlled density. Powder discs were tested for wettability by dispensing a controlled volume of water and motor oil onto the surface and measuring the time required for each fluid to imbibe into the sample. The syringe and software of a CAM101 tensiometer were used to control the amount of fluid dispensed onto each sample, and imbibition completion times were determined by high-speed photography for water drops; oil drop imbibition was significantly slower and imbibition was timed and determined visually. Contact angle of water and oil drops on polished chert and mineral sample surfaces was determined by image analysis and the Young-Laplace equation. Oil imbibition was significantly slower with increased detrital composition and faster with increased silica content in opal-CT and quartz phase samples, implying decreased wettability to oil with increased detrital (clay) content. However, contact angle tests showed that opal-CT is more wetting to oil with increased detritus and results for oil on quartz-phase samples were inconsistent between different proxies for detritus over their very small compositional range. Water contact angle trends also showed inconsistent wetting trends compared to imbibition tests. We believe this is because the small range in bulk detrital composition between the "pure" samples used in contact angle tests was close to analytical error and because small-scale spatial compositional variability may be significant enough to effect wettability. These experiments show that compositional variables significantly affect wettability, outweighing the effect of silica phase.

  1. Chicken barn climate and hazardous volatile compounds control using simple linear regression and PID

    NASA Astrophysics Data System (ADS)

    Abdullah, A. H.; Bakar, M. A. A.; Shukor, S. A. A.; Saad, F. S. A.; Kamis, M. S.; Mustafa, M. H.; Khalid, N. S.

    2016-07-01

    The hazardous volatile compounds from chicken manure in chicken barn are potentially to be a health threat to the farm animals and workers. Ammonia (NH3) and hydrogen sulphide (H2S) produced in chicken barn are influenced by climate changes. The Electronic Nose (e-nose) is used for the barn's air, temperature and humidity data sampling. Simple Linear Regression is used to identify the correlation between temperature-humidity, humidity-ammonia and ammonia-hydrogen sulphide. MATLAB Simulink software was used for the sample data analysis using PID controller. Results shows that the performance of PID controller using the Ziegler-Nichols technique can improve the system controller to control climate in chicken barn.

  2. CRUMP 2003 Selected Water Sample Results

    EPA Pesticide Factsheets

    Point locations and water sampling results performed in 2003 by the Church Rock Uranium Monitoring Project (CRUMP) a consortium of organizations (Navajo Nation Environmental Protection Agency, US Environmental Protection Agency, New Mexico Scientific Laboratory Division, Navajo Tribal Utility Authority and NM Water Quality Control Commission). Samples include general description of the wells sampled, general chemistry, heavy metals and aestheic parameters, and selected radionuclides. Here only six sampling results are presented in this point shapefile, including: Gross Alpha (U-Nat Ref.) (pCi/L), Gross Beta (Sr/Y-90 Ref.) (pCi/L), Radium-226 (pCi/L), Radium-228 (pCi/L), Total Uranium (pCi/L), and Uranium mass (ug/L). The CRUMP samples were collected in the area of Churchrock, NM in the Eastern AUM Region of the Navajo Nation.

  3. RNA-Seq-based toxicogenomic assessment of fresh frozen and formalin-fixed tissues yields similar mechanistic insights.

    PubMed

    Auerbach, Scott S; Phadke, Dhiral P; Mav, Deepak; Holmgren, Stephanie; Gao, Yuan; Xie, Bin; Shin, Joo Heon; Shah, Ruchir R; Merrick, B Alex; Tice, Raymond R

    2015-07-01

    Formalin-fixed, paraffin-embedded (FFPE) pathology specimens represent a potentially vast resource for transcriptomic-based biomarker discovery. We present here a comparison of results from a whole transcriptome RNA-Seq analysis of RNA extracted from fresh frozen and FFPE livers. The samples were derived from rats exposed to aflatoxin B1 (AFB1 ) and a corresponding set of control animals. Principal components analysis indicated that samples were separated in the two groups representing presence or absence of chemical exposure, both in fresh frozen and FFPE sample types. Sixty-five percent of the differentially expressed transcripts (AFB1 vs. controls) in fresh frozen samples were also differentially expressed in FFPE samples (overlap significance: P < 0.0001). Genomic signature and gene set analysis of AFB1 differentially expressed transcript lists indicated highly similar results between fresh frozen and FFPE at the level of chemogenomic signatures (i.e., single chemical/dose/duration elicited transcriptomic signatures), mechanistic and pathology signatures, biological processes, canonical pathways and transcription factor networks. Overall, our results suggest that similar hypotheses about the biological mechanism of toxicity would be formulated from fresh frozen and FFPE samples. These results indicate that phenotypically anchored archival specimens represent a potentially informative resource for signature-based biomarker discovery and mechanistic characterization of toxicity. Copyright © 2014 John Wiley & Sons, Ltd.

  4. Method matters: Experimental evidence for shorter avian sperm in faecal compared to abdominal massage samples.

    PubMed

    Girndt, Antje; Cockburn, Glenn; Sánchez-Tójar, Alfredo; Løvlie, Hanne; Schroeder, Julia

    2017-01-01

    Birds are model organisms in sperm biology. Previous work in zebra finches, suggested that sperm sampled from males' faeces and ejaculates do not differ in size. Here, we tested this assumption in a captive population of house sparrows, Passer domesticus. We compared sperm length in samples from three collection techniques: female dummy, faecal and abdominal massage samples. We found that sperm were significantly shorter in faecal than abdominal massage samples, which was explained by shorter heads and midpieces, but not flagella. This result might indicate that faecal sampled sperm could be less mature than sperm collected by abdominal massage. The female dummy method resulted in an insufficient number of experimental ejaculates because most males ignored it. In light of these results, we recommend using abdominal massage as a preferred method for avian sperm sampling. Where avian sperm cannot be collected by abdominal massage alone, we advise controlling for sperm sampling protocol statistically.

  5. Wear resistance of Polymethyl Methacrylate (PMMA) with the Addition of Bone Ash, Hydroxylapatite and Keratin

    NASA Astrophysics Data System (ADS)

    Emre, G.; Akkus, A.; Karamış, M. B.

    2018-01-01

    In this study mechanichal and tribological properties of keratin, bone ash and hydroxylapatite by adding to PMMA ( known as the main prosthesis material) were investigated. Hydroxylapatite, bone ash, and keratin materials were added as PMMA in to the content of PMMA, in the proportions of %1, %3 and %5, respectively. The resulting mixtures were put into the molds and solidified in order to obtain samples to be used in the wear experiments. Each experiment was conducted by preparing three experimental samples. The wear data were compared according to the average values of the experimental samples. In the wear test, the results were also evaluated according to the average values obtained from each group and the results of the control group. It was observed that, the wear resistance of the PMMA including 3%, 5% bone ash and PMMA including 5% keratin flour were higher than the values of the control group.

  6. Novel statistical framework to identify differentially expressed genes allowing transcriptomic background differences.

    PubMed

    Ling, Zhi-Qiang; Wang, Yi; Mukaisho, Kenichi; Hattori, Takanori; Tatsuta, Takeshi; Ge, Ming-Hua; Jin, Li; Mao, Wei-Min; Sugihara, Hiroyuki

    2010-06-01

    Tests of differentially expressed genes (DEGs) from microarray experiments are based on the null hypothesis that genes that are irrelevant to the phenotype/stimulus are expressed equally in the target and control samples. However, this strict hypothesis is not always true, as there can be several transcriptomic background differences between target and control samples, including different cell/tissue types, different cell cycle stages and different biological donors. These differences lead to increased false positives, which have little biological/medical significance. In this article, we propose a statistical framework to identify DEGs between target and control samples from expression microarray data allowing transcriptomic background differences between these samples by introducing a modified null hypothesis that the gene expression background difference is normally distributed. We use an iterative procedure to perform robust estimation of the null hypothesis and identify DEGs as outliers. We evaluated our method using our own triplicate microarray experiment, followed by validations with reverse transcription-polymerase chain reaction (RT-PCR) and on the MicroArray Quality Control dataset. The evaluations suggest that our technique (i) results in less false positive and false negative results, as measured by the degree of agreement with RT-PCR of the same samples, (ii) can be applied to different microarray platforms and results in better reproducibility as measured by the degree of DEG identification concordance both intra- and inter-platforms and (iii) can be applied efficiently with only a few microarray replicates. Based on these evaluations, we propose that this method not only identifies more reliable and biologically/medically significant DEG, but also reduces the power-cost tradeoff problem in the microarray field. Source code and binaries freely available for download at http://comonca.org.cn/fdca/resources/softwares/deg.zip.

  7. Innovative application of the moisture analyzer for determination of dry mass content of processed cheese

    NASA Astrophysics Data System (ADS)

    Kowalska, Małgorzata; Janas, Sławomir; Woźniak, Magdalena

    2018-04-01

    The aim of this work was the presentation of an alternative method of determination of the total dry mass content in processed cheese. The authors claim that the presented method can be used in industry's quality control laboratories for routine testing and for quick in-process control. For the test purposes both reference method of determination of dry mass in processed cheese and moisture analyzer method were used. The tests were carried out for three different kinds of processed cheese. In accordance with the reference method, the sample was placed on a layer of silica sand and dried at the temperature of 102 °C for about 4 h. The moisture analyzer test required method validation, with regard to drying temperature range and mass of the analyzed sample. Optimum drying temperature of 110 °C was determined experimentally. For Hochland cream processed cheese sample, the total dry mass content, obtained using the reference method, was 38.92%, whereas using the moisture analyzer method, it was 38.74%. An average analysis time in case of the moisture analyzer method was 9 min. For the sample of processed cheese with tomatoes, the reference method result was 40.37%, and the alternative method result was 40.67%. For the sample of cream processed cheese with garlic the reference method gave value of 36.88%, and the alternative method, of 37.02%. An average time of those determinations was 16 min. Obtained results confirmed that use of moisture analyzer is effective. Compliant values of dry mass content were obtained for both of the used methods. According to the authors, the fact that the measurement took incomparably less time for moisture analyzer method, is a key criterion of in-process control and final quality control method selection.

  8. In vitro test of external Qigong

    PubMed Central

    Yount, Garret; Solfvin, Jerry; Moore, Dan; Schlitz, Marilyn; Reading, Melissa; Aldape, Ken; Qian, Yifang

    2004-01-01

    Background Practitioners of the alternative medical practice 'external Qigong' generally claim the ability to emit or direct "healing energy" to treat patients. We investigated the ability of experienced Qigong practitioners to enhance the healthy growth of cultured human cells in a series of studies, each following a rigorously designed protocol with randomization, blinding and controls for variability. Methods Qigong practitioners directed healing intentionality toward normal brain cell cultures in a basic science laboratory. Qigong treatments were delivered for 20 minutes from a minimum distance of 10 centimeters. Cell proliferation was measured by a standard colony-forming efficiency (CFE) assay and a CFE ratio (CFE for treated samples/CFE for sham samples) was the dependent measure for each experiment. Results During a pilot study (8 experiments), a trend of increased cell proliferation in Qigong-treated samples (CFE Qigong/sham ratios > 1.0) was observed (P = 0.162). In a formal study (28 experiments), a similar trend was observed, with Qigong-treated samples showing on average more colony formation than sham samples (P = 0.036). In a replication study (60 experiments), no significant difference between Qigong-treated samples and sham samples was observed (P = 0.465). Conclusion We observed an apparent increase in the proliferation of cultured cells following external Qigong treatment by practitioners under strictly controlled conditions, but we did not observe this effect in a replication study. These results suggest the need for more controlled and thorough investigation of external Qigong before scientific validation is claimed. PMID:15102336

  9. Representativeness of laboratory sampling procedures for the analysis of trace metals in soil.

    PubMed

    Dubé, Jean-Sébastien; Boudreault, Jean-Philippe; Bost, Régis; Sona, Mirela; Duhaime, François; Éthier, Yannic

    2015-08-01

    This study was conducted to assess the representativeness of laboratory sampling protocols for purposes of trace metal analysis in soil. Five laboratory protocols were compared, including conventional grab sampling, to assess the influence of sectorial splitting, sieving, and grinding on measured trace metal concentrations and their variability. It was concluded that grinding was the most important factor in controlling the variability of trace metal concentrations. Grinding increased the reproducibility of sample mass reduction by rotary sectorial splitting by up to two orders of magnitude. Combined with rotary sectorial splitting, grinding increased the reproducibility of trace metal concentrations by almost three orders of magnitude compared to grab sampling. Moreover, results showed that if grinding is used as part of a mass reduction protocol by sectorial splitting, the effect of sieving on reproducibility became insignificant. Gy's sampling theory and practice was also used to analyze the aforementioned sampling protocols. While the theoretical relative variances calculated for each sampling protocol qualitatively agreed with the experimental variances, their quantitative agreement was very poor. It was assumed that the parameters used in the calculation of theoretical sampling variances may not correctly estimate the constitutional heterogeneity of soils or soil-like materials. Finally, the results have highlighted the pitfalls of grab sampling, namely, the fact that it does not exert control over incorrect sampling errors and that it is strongly affected by distribution heterogeneity.

  10. Performance evaluation of a mitogenome capture and Illumina sequencing protocol using non-probative, case-type skeletal samples: Implications for the use of a positive control in a next-generation sequencing procedure.

    PubMed

    Marshall, Charla; Sturk-Andreaggi, Kimberly; Daniels-Higginbotham, Jennifer; Oliver, Robert Sean; Barritt-Ross, Suzanne; McMahon, Timothy P

    2017-11-01

    Next-generation ancient DNA technologies have the potential to assist in the analysis of degraded DNA extracted from forensic specimens. Mitochondrial genome (mitogenome) sequencing, specifically, may be of benefit to samples that fail to yield forensically relevant genetic information using conventional PCR-based techniques. This report summarizes the Armed Forces Medical Examiner System's Armed Forces DNA Identification Laboratory's (AFMES-AFDIL) performance evaluation of a Next-Generation Sequencing protocol for degraded and chemically treated past accounting samples. The procedure involves hybridization capture for targeted enrichment of mitochondrial DNA, massively parallel sequencing using Illumina chemistry, and an automated bioinformatic pipeline for forensic mtDNA profile generation. A total of 22 non-probative samples and associated controls were processed in the present study, spanning a range of DNA quantity and quality. Data were generated from over 100 DNA libraries by ten DNA analysts over the course of five months. The results show that the mitogenome sequencing procedure is reliable and robust, sensitive to low template (one ng control DNA) as well as degraded DNA, and specific to the analysis of the human mitogenome. Haplotypes were overall concordant between NGS replicates and with previously generated Sanger control region data. Due to the inherent risk for contamination when working with low-template, degraded DNA, a contamination assessment was performed. The consumables were shown to be void of human DNA contaminants and suitable for forensic use. Reagent blanks and negative controls were analyzed to determine the background signal of the procedure. This background signal was then used to set analytical and reporting thresholds, which were designated at 4.0X (limit of detection) and 10.0X (limit of quantiation) average coverage across the mitogenome, respectively. Nearly all human samples exceeded the reporting threshold, although coverage was reduced in chemically treated samples resulting in a ∼58% passing rate for these poor-quality samples. A concordance assessment demonstrated the reliability of the NGS data when compared to known Sanger profiles. One case sample was shown to be mixed with a co-processed sample and two reagent blanks indicated the presence of DNA above the analytical threshold. This contamination was attributed to sequencing crosstalk from simultaneously sequenced high-quality samples to include the positive control. Overall this study demonstrated that hybridization capture and Illumina sequencing provide a viable method for mitogenome sequencing of degraded and chemically treated skeletal DNA samples, yet may require alternative measures of quality control. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  11. Process control using fiber optics and Fourier transform infrared spectroscopy

    NASA Astrophysics Data System (ADS)

    Kemsley, E. K.; Wilson, Reginald H.

    1992-03-01

    A process control system has been constructed using optical fibers interfaced to a Fourier transform infrared (FT-IR) spectrometer, to achieve remote spectroscopic analysis of food samples during processing. The multichannel interface accommodates six fibers, allowing the sequential observation of up to six samples. Novel fiber-optic sampling cells have been constructed, including transmission and attenuated total reflectance (ATR) designs. Different fiber types have been evaluated; in particular, plastic clad silica (PCS) and zirconium fluoride fibers. Processes investigated have included the dilution of fruit juice concentrate, and the addition of alcohol to fruit syrup. Suitable algorithms have been written which use the results of spectroscopic measurements to control and monitor the course of each process, by actuating devices such as valves and switches.

  12. Selective Laser Melting of Metal Powder Of Steel 3161

    NASA Astrophysics Data System (ADS)

    Smelov, V. G.; Sotov, A. V.; Agapovichev, A. V.; Tomilina, T. M.

    2016-08-01

    In this article the results of experimental study of the structure and mechanical properties of materials obtained by selective laser melting (SLM), metal powder steel 316L was carried out. Before the process of cultivation of samples as the input control, the morphology of the surface of the powder particles was studied and particle size analysis was carried out. Also, 3D X-ray quality control of the grown samples was carried out in order to detect hidden defects, their qualitative and quantitative assessment. To determine the strength characteristics of the samples synthesized by the SLM method, static tensile tests were conducted. To determine the stress X-ray diffraction analysis was carried out in the material samples.

  13. MTHFR c.677C>T is a risk factor for non-syndromic cleft lip with or without cleft palate in Chile.

    PubMed

    Ramírez-Chau, C; Blanco, R; Colombo, A; Pardo, R; Suazo, J

    2016-10-01

    The functional variant within the 5,10-methylenetetrahydrofolate reductase (MTHFR) gene c.677C>T, producing alterations in folate metabolism, has been associated with the risk of non-syndromic cleft lip with or without cleft palate (NSCL/P). We assessed this association in a Chilean population using a combined analysis of case-control and case-parent trio samples. Samples of 165 cases and 291 controls and 121 case-parent trios (sharing the cases) were genotyped. Odds ratio (OR) was estimated for case-control (allele and genotype frequency differences), and this result was confirmed by allele transmission distortion in trios. Due to that these samples are not independent, a combined OR was also computed. Maternal genotype effect was additionally evaluated based on a log-linear method. Borderline but not significant OR (1.28; CI 0.97-1.69) was observed for risk allele (T) in the case-control sample. However, triad sample showed a significant association (OR 1.56: CI 1.09-2.25) which was confirmed by the combined OR (1.37; CI 1.11-1.71). Maternal genotype has been also associated with the phenotype (P = 0.002). In contrast to previous reports considering Chilean subjects, our results demonstrated that the offspring and maternal genotypes for MTHFR c.677C>T variant are strongly associated with NSCL/P in this Chilean population. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Bayesian posterior distributions without Markov chains.

    PubMed

    Cole, Stephen R; Chu, Haitao; Greenland, Sander; Hamra, Ghassan; Richardson, David B

    2012-03-01

    Bayesian posterior parameter distributions are often simulated using Markov chain Monte Carlo (MCMC) methods. However, MCMC methods are not always necessary and do not help the uninitiated understand Bayesian inference. As a bridge to understanding Bayesian inference, the authors illustrate a transparent rejection sampling method. In example 1, they illustrate rejection sampling using 36 cases and 198 controls from a case-control study (1976-1983) assessing the relation between residential exposure to magnetic fields and the development of childhood cancer. Results from rejection sampling (odds ratio (OR) = 1.69, 95% posterior interval (PI): 0.57, 5.00) were similar to MCMC results (OR = 1.69, 95% PI: 0.58, 4.95) and approximations from data-augmentation priors (OR = 1.74, 95% PI: 0.60, 5.06). In example 2, the authors apply rejection sampling to a cohort study of 315 human immunodeficiency virus seroconverters (1984-1998) to assess the relation between viral load after infection and 5-year incidence of acquired immunodeficiency syndrome, adjusting for (continuous) age at seroconversion and race. In this more complex example, rejection sampling required a notably longer run time than MCMC sampling but remained feasible and again yielded similar results. The transparency of the proposed approach comes at a price of being less broadly applicable than MCMC.

  15. LINER galaxy properties and the local environment

    NASA Astrophysics Data System (ADS)

    Coldwell, Georgina V.; Alonso, Sol; Duplancic, Fernanda; Mesa, Valeria

    2018-05-01

    We analyse the properties of a sample of 5560 low-ionization nuclear emission-line region (LINER) galaxies selected from SDSS-DR12 at low red shift, for a complete range of local density environments. The host LINER galaxies were studied and compared with a well-defined control sample of 5553 non-LINER galaxies matched in red shift, luminosity, morphology and local density. By studying the distributions of galaxy colours and the stellar age population, we find that LINERs are redder and older than the control sample over a wide range of densities. In addition, LINERs are older than the control sample, at a given galaxy colour, indicating that some external process could have accelerated the evolution of the stellar population. The analysis of the host properties shows that the control sample exhibits a strong relation between colours, ages and the local density, while more than 90 per cent of the LINERs are redder and older than the mean values, independently of the neighbourhood density. Furthermore, a detailed study in three local density ranges shows that, while control sample galaxies are redder and older as a function of stellar mass and density, LINER galaxies mismatch the known morphology-density relation of galaxies without low-ionization features. The results support the contribution of hot and old stars to the low-ionization emission although the contribution of nuclear activity is not discarded.

  16. Ten years of preanalytical monitoring and control: Synthetic Balanced Score Card Indicator

    PubMed Central

    López-Garrigós, Maite; Flores, Emilio; Santo-Quiles, Ana; Gutierrez, Mercedes; Lugo, Javier; Lillo, Rosa; Leiva-Salinas, Carlos

    2015-01-01

    Introduction Preanalytical control and monitoring continue to be an important issue for clinical laboratory professionals. The aim of the study was to evaluate a monitoring system of preanalytical errors regarding not suitable samples for analysis, based on different indicators; to compare such indicators in different phlebotomy centres; and finally to evaluate a single synthetic preanalytical indicator that may be included in the balanced scorecard management system (BSC). Materials and methods We collected individual and global preanalytical errors in haematology, coagulation, chemistry, and urine samples analysis. We also analyzed a synthetic indicator that represents the sum of all types of preanalytical errors, expressed in a sigma level. We studied the evolution of those indicators over time and compared indicator results by way of the comparison of proportions and Chi-square. Results There was a decrease in the number of errors along the years (P < 0.001). This pattern was confirmed in primary care patients, inpatients and outpatients. In blood samples, fewer errors occurred in outpatients, followed by inpatients. Conclusion We present a practical and effective methodology to monitor unsuitable sample preanalytical errors. The synthetic indicator results summarize overall preanalytical sample errors, and can be used as part of BSC management system. PMID:25672466

  17. Actinomyces israelii in radicular cysts: a molecular study.

    PubMed

    Gomes, Nathália Rodrigues; Diniz, Marina Gonçalves; Pereira, Thais Dos Santos Fontes; Estrela, Carlos; de Macedo Farias, Luiz; de Andrade, Bruno Augusto Benevenuto; Gomes, Carolina Cavaliéri; Gomez, Ricardo Santiago

    2017-05-01

    To investigate whether the microscopic filamentous aggregates observed in radicular cysts are associated with the molecular identification of Actinomyces israelii. Moreover, to verify whether this bacterium can be detected in radicular cyst specimens not presenting aggregates. Microscopic colonies suggestive of Actinomyces were found in 8 out of 279 radicular cyst samples (case group). The case and control groups (n = 12; samples without filamentous colonies) were submitted to the semi-nested polymerase chain reaction to test the presence of A israelii. DNA sequencing was performed to validate polymerase chain reaction results. Two and 3 samples in the case and control groups, respectively, did not present a functional genomic DNA template and were excluded from the study. A israelii was identified in all samples of the case group and in 3 out of 9 samples of the control group. Although A israelii is more commonly identified in radicular cysts presenting filamentous aggregates, it also appears to be detected in radicular cysts without this microscopic finding. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Analysis of Tank 38H (HTF-38-15-119, 127) Surface, Subsurface and Tank 43H (HTF-43-15-116, 117 and 118) Surface, Feed Pump Suction and Jet Suction Subsurface Supernatant Samples in Support of Enrichment, Corrosion Control and Salt Batch Planning Programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oji, L.

    Compositional feed limits have been established to ensure that a nuclear criticality event for the 2H and 3H Evaporators is not possible. The Enrichment Control Program (ECP) requires feed sampling to determine the equivalent enriched uranium content prior to transfer of waste other than recycle transfers (requires sampling to determine the equivalent enriched uranium at two locations in Tanks 38H and 43H every 26 weeks) The Corrosion Control Program (CCP) establishes concentration and temperature limits for key constituents and periodic sampling and analysis to confirm that waste supernate is within these limits. This report provides the results of analyses onmore » Tanks 38H and 43H surface and subsurface supernatant liquid samples in support of the ECP, the CCP, and the Salt Batch 10 Planning Program.« less

  19. Adaptive control of theophylline therapy: importance of blood sampling times.

    PubMed

    D'Argenio, D Z; Khakmahd, K

    1983-10-01

    A two-observation protocol for estimating theophylline clearance during a constant-rate intravenous infusion is used to examine the importance of blood sampling schedules with regard to the information content of resulting concentration data. Guided by a theory for calculating maximally informative sample times, population simulations are used to assess the effect of specific sampling times on the precision of resulting clearance estimates and subsequent predictions of theophylline plasma concentrations. The simulations incorporated noise terms for intersubject variability, dosing errors, sample collection errors, and assay error. Clearance was estimated using Chiou's method, least squares, and a Bayesian estimation procedure. The results of these simulations suggest that clinically significant estimation and prediction errors may result when using the above two-point protocol for estimating theophylline clearance if the time separating the two blood samples is less than one population mean elimination half-life.

  20. 'Mitominis': multiplex PCR analysis of reduced size amplicons for compound sequence analysis of the entire mtDNA control region in highly degraded samples.

    PubMed

    Eichmann, Cordula; Parson, Walther

    2008-09-01

    The traditional protocol for forensic mitochondrial DNA (mtDNA) analyses involves the amplification and sequencing of the two hypervariable segments HVS-I and HVS-II of the mtDNA control region. The primers usually span fragment sizes of 300-400 bp each region, which may result in weak or failed amplification in highly degraded samples. Here we introduce an improved and more stable approach using shortened amplicons in the fragment range between 144 and 237 bp. Ten such amplicons were required to produce overlapping fragments that cover the entire human mtDNA control region. These were co-amplified in two multiplex polymerase chain reactions and sequenced with the individual amplification primers. The primers were carefully selected to minimize binding on homoplasic and haplogroup-specific sites that would otherwise result in loss of amplification due to mis-priming. The multiplexes have successfully been applied to ancient and forensic samples such as bones and teeth that showed a high degree of degradation.

  1. [Application of laboratory information system in the management of the key indicators of quality inspection].

    PubMed

    Guo, Ye; Chen, Qian; Wu, Wei; Cui, Wei

    2015-03-31

    To establish a system of monitoring the key indicator of quality for inspection (KIQI) on a laboratory information system (LIS), and to have a better management of KIQI. Clinical sample made in PUMCH were collected during the whole of 2014. Next, interactive input program were designed to accomplish data collecting of the disqualification rate of samples, the mistake rate of samples and the occasions of losing samples, etc. Then, a series moment of sample collection, laboratory sample arrived, sample test, sample check, response to critical value, namely, trajectory information left on LIS were recorded and the qualification rate of TAT, the notification rate of endangering result were calculated. Finally, the information about quality control were collected to build an internal quality control database and the KIQI, such as the out-of-control rate of quality control and the total error of test items were monitored. The inspection of the sample management shows the disqualification rates in 2014 were all below the target, but the rates in January and February were a little high and the rates of four wards were above 2%. The mistake rates of samples was 0.47 cases/10 000 cases, attaining the target (< 2 cases/10 000 cases). Also, there was no occasion of losing samples in 2014, attaining the target too. The inspection of laboratory reports shows the qualification rates of TAT was within the acceptable range (> 95%), however the rates of blood routine in November (94.75%) was out of range. We have solved the problem by optimizing the processes. The notification rate of endangering result attained the target (≥ 98%), while the rate of timely notification is needed to improve. Quality inspection shows the CV of APTT in August (5.02%) was rising significantly, beyond the accepted CV (5.0%). We have solved the problem by changing the reagent. The CV of TT in 2014 were all below the allowable CV, thus the allowable CV of the next year lower to 10%. It is an objective and effective method to manage KIQI with the powerful management mode of database and information process capability on LIS.

  2. Could cryopreserved human semen samples be stored at -80°C?

    PubMed Central

    Vaz, Carlos R; Lamim, Tamara; Salvador, Rafael A; Batschauer, Anna P B; Amaral, Vera Lucia L; Til, David

    2018-01-01

    Objective To evaluate storage time effects in cryopreserved human semen samples, kept in the freezer at a controlled temperature of -80°C, on sperm viability after thawing. Methods We used 20 semen samples. Each sample was cryopreserved in 10 fingers, which were divided into five groups: one group was kept in cryogenic canisters throughout the experiment(control), and four groups were kept in a VIP Ultra Low MDF-U76V- PE freezer, with the temperature set at -80°C, for 24, 48, 72 and 96 hours, respectively. After the exposure time, the samples were stored in cryogenic canisters after being thawed. The analyzed parameters were: motility, vitality and mitochondrial activity. Results After thawing, we noticed decreased sperm motility, vitality and mitochondrial activity, when comparing the tested groups with the control group, as well as a progressive reduction in the analyzed parameters between the times evaluated. Conclusions Cryopreservation of semen samples at -80°C is potentially harmful to sperm viability, causing damage when submitted to longer exposure times. PMID:29338138

  3. Use of capillary Western immunoassay (Wes) for quantification of dystrophin levels in skeletal muscle of healthy controls and individuals with Becker and Duchenne muscular dystrophy.

    PubMed

    Beekman, Chantal; Janson, Anneke A; Baghat, Aabed; van Deutekom, Judith C; Datson, Nicole A

    2018-01-01

    Duchenne muscular dystrophy (DMD) is a neuromuscular disease characterized by progressive weakness of the skeletal and cardiac muscles. This X-linked disorder is caused by open reading frame disrupting mutations in the DMD gene, resulting in strong reduction or complete absence of dystrophin protein. In order to use dystrophin as a supportive or even surrogate biomarker in clinical studies on investigational drugs aiming at correcting the primary cause of the disease, the ability to reliably quantify dystrophin expression in muscle biopsies of DMD patients pre- and post-treatment is essential. Here we demonstrate the application of the ProteinSimple capillary immunoassay (Wes) method, a gel- and blot-free method requiring less sample, antibody and time to run than conventional Western blot assay. We optimized dystrophin quantification by Wes using 2 different antibodies and found it to be highly sensitive, reproducible and quantitative over a large dynamic range. Using a healthy control muscle sample as a reference and α-actinin as a protein loading/muscle content control, a panel of skeletal muscle samples consisting of 31 healthy controls, 25 Becker Muscle dystrophy (BMD) and 17 DMD samples was subjected to Wes analysis. In healthy controls dystrophin levels varied 3 to 5-fold between the highest and lowest muscle samples, with the reference sample representing the average of all 31 samples. In BMD muscle samples dystrophin levels ranged from 10% to 90%, with an average of 33% of the healthy muscle average, while for the DMD samples the average dystrophin level was 1.3%, ranging from 0.7% to 7% of the healthy muscle average. In conclusion, Wes is a suitable, efficient and reliable method for quantification of dystrophin expression as a biomarker in DMD clinical drug development.

  4. A proficiency testing program of hemoglobin analysis in prevention and control of severe hemoglobinopathies in Thailand.

    PubMed

    Karnpean, Rossarin; Fucharoen, Goonnapa; Pansuwan, Anupong; Changtrakul, Duangrudee; Fucharoen, Supan

    2013-06-01

    No external quality assessment program for hemoglobin (Hb) analysis in the prevention and control of thalassemia has been established in Thailand. To improve the first line provisional diagnostics, the first proficiency testing (PT) program has been established. External Hb controls prepared at our center were sent to Hb analysis laboratories all over the country. Three cycles per year were performed in 2010 and 2011. In each cycle, two control samples with corresponding hematological parameters, designated as husband and his pregnant wife were supplied for Hb analysis. Each member analyzed the control samples in their routine practices. The results of Hb analysis, laboratory interpretation and risk assessment of the expected fetus for severe thalassemia diseases targeted for prevention and control were entered into the report form and sent back to our center. Participants reports were analyzed and classified into four different quality groups; Excellent (when all the three parameters are correct), Good (correct Hb analysis and interpretation but incorrect risk assessment), Fair (correct Hb analysis but incorrect interpretation and risk assessment) and Needs improvement (incorrect Hb analysis). It was found that most participants could report correct Hb types and quantifications but some misinterpretations and risk assessments were noted. These were clearly seen when control samples with more complexity were supplied. These results indicate a further improvement is required in the laboratory interpretation and knowledge of the laboratory diagnosis of thalassemia. The established system should facilitate the prevention and control program of thalassemia in the region.

  5. The Study of Pentoxifylline Drug Effects on Renal Apoptosis and BCL-2 Gene Expression Changes Following Ischemic Reperfusion Injury in Rat

    PubMed Central

    Hashemi, Mehrdad

    2014-01-01

    Ischemia Reperfusion injury is the tissue damage caused when blood supply returns to the tissue after a period of ischemia or lack of oxygen. In this study, the effect of pentoxyfylline on BCL-2 gene expression changes and cell injury in kidney of rat following Ischemia Reperfusion were evaluated. In this experimental study, 20 male wistar rats with average weight of 250-300 g were selected and then were accidently divided them on two tenth group of control and treatment groups. In the control group, celiotomy was performed by ventral midline incision. The left kidney was isolated, and then both the renal artery and vein were obstructed. After 60 minutes of warm ischemia, vessel obstruction resolved and the right kidney was removed. 72 hours after reperfusion, tissue samples were taken from left kidney for Tunel assay. We used quantitative real time PCR for detection of BCL-2 gene expression in treated groups and then compared them to control samples. In the treatment group, the cell death changes, showed lower level than the control group. The results also showed the BCL-2 gene expression was declined in ischemia group as campared to PNT drug group. The pentoxyfylline might have a role in control of apoptosis result from Ischemia- reperfusion and quantitative real-time PCR can be used as a direct method for detection BCL-2 gene expression in tested samples and normal samples. PMID:24734070

  6. Validation of the Korean Version of the Eating Disorder Inventory-2: Psychometric Properties and Cross-Cultural Comparison

    PubMed Central

    Lee, Jung-Hyun; Shin, Mi-Yeon; Jo, Hye-Hyeon; Jung, Young-Chul; Kim, Joon-Ki

    2012-01-01

    Purpose The purpose of the present study was to examine the validity and reliability of the Korean version of the Eating Disorder Inventory-2 (EDI-2) in Korean patients with eating disorders and healthy controls, and to investigate cultural differences of EDI-2 between a Korean group and a North American standardization sample. Materials and Methods The Korean version of the EDI-2 was prepared after comprehensive clinical assessment of Korean patients with eating disorders (n=327) as well as female undergraduates (n=176). Results were compared between eating disorder subgroups (anorexia nervosa, bulimia nervosa and eating disorders not otherwise specified) and those of a North American standardization sample and healthy controls. Results The results showed that the Korean EDI-2 had adequate internal consistency (0.77-0.93) and discriminated well between patients with eating disorders and healthy controls on all subscales. Significant differences in EDI-2 subscale scores between the eating disorder groups and the healthy control group were observed; however, there was no discernible difference among the eating disorder subgroups. When compared with a North American standardization sample, the Korean control group showed significantly higher scores for drive for thinness and asceticism. When patient groups were compared, the Korean group showed significantly lower scores for perfectionism. Conclusion As expected, the results accurately reflected psychometric properties of the Korean version of EDI-2 for eating disorder patients in Korea. These findings also suggest that common characteristics for the eating disorder exist as a whole rather than with significant difference between each subgroup. In addition, significant differences between the Korean and the North American groups for both patients and controls also demonstrated specific cultural differences. PMID:23074108

  7. Radionuclide Concentrations in Honey Bees from Area G at TA-54 during 1998

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haarmann, T.K.; Fresquez, P.R.

    Honey bees were collected from two colonies located at Los Alamos National Laboratory's Area G, Technical Area 54, and from one control (background) colony located near Jemez Springs, NM. Samples were analyzed for various radionuclides. Area G sample results from both colonies were higher than the upper (95%) level background concentration for {sup 239,240}Pu, {sup 3}H, and total uranium. Sample results from one colony were higher than the upper (95%) level background concentration for {sup 238}Pu.

  8. Development of a predictive model for the growth kinetics of aerobic microbial population on pomegranate marinated chicken breast fillets under isothermal and dynamic temperature conditions.

    PubMed

    Lytou, Anastasia; Panagou, Efstathios Z; Nychas, George-John E

    2016-05-01

    The aim of this study was the development of a model to describe the growth kinetics of aerobic microbial population of chicken breast fillets marinated in pomegranate juice under isothermal and dynamic temperature conditions. Moreover, the effect of pomegranate juice on the extension of the shelf life of the product was investigated. Samples (10 g) of chicken breast fillets were immersed in marinades containing pomegranate juice for 3 h at 4 °C following storage under aerobic conditions at 4, 10, and 15 °C for 10 days. Total Viable Counts (TVC), Pseudomonas spp and lactic acid bacteria (LAB) were enumerated, in parallel with sensory assessment (odor and overall appearance) of marinated and non-marinated samples. The Baranyi model was fitted to the growth data of TVC to calculate the maximum specific growth rate (μmax) that was further modeled as a function of temperature using a square root-type model. The validation of the model was conducted under dynamic temperature conditions based on two fluctuating temperature scenarios with periodic changes from 6 to 13 °C. The shelf life was determined both mathematically and with sensory assessment and its temperature dependence was modeled by an Arrhenius type equation. Results showed that the μmax of TVC of marinated samples was significantly lower compared to control samples regardless temperature, while under dynamic temperature conditions the model satisfactorily predicted the growth of TVC in both control and marinated samples. The shelf-life of marinated samples was significantly extended compared to the control (5 days extension at 4 °C). The calculated activation energies (Ea), 82 and 52 kJ/mol for control and marinated samples, respectively, indicated higher temperature dependence of the shelf life of control samples compared to marinated ones. The present results indicated that pomegranate juice could be used as an alternative ingredient in marinades to prolong the shelf life of chicken. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Self-reported impulsivity, but not behavioral approach or inhibition, mediates the relationship between stress and self-control

    PubMed Central

    Hamilton, Kristen R.; Sinha, Rajita; Potenza, Marc N.

    2014-01-01

    Stress has been associated with poor self-control. Individual differences in impulsivity and other behavioral tendencies may influence the relationship of stress with self-control, although this possibility has not been examined to date. The present research investigated whether cumulative stress is associated with poor self-control, and whether this relationship is mediated by impulsivity, behavioral approach, and behavioral inhibition in men and women. A community sample of 566 adults (319 women and 247 men) was assessed on the Cumulative Adversity Interview, Brief Self-control Scale, Barratt Impulsivity Scale, and Behavioral Activation System and Behavioral Inhibition System Scale (BIS/BAS). Data were analyzed using regression and bootstrapping techniques. In the total sample, the effects of cumulative stress on self-control were mediated by impulsivity. Neither behavioral inhibition nor behavioral approach mediated the association between cumulative stress and self-control in the total sample. Results were similar when men and women were considered separately, with impulsivity, but not behavioral inhibition or approach, mediating the association between cumulative stress and self-control. Impulsive individuals might benefit preferentially from interventions focusing on stress management and strategies for improving self-control. PMID:24508183

  10. Self-reported impulsivity, but not behavioral approach or inhibition, mediates the relationship between stress and self-control.

    PubMed

    Hamilton, Kristen R; Sinha, Rajita; Potenza, Marc N

    2014-11-01

    Stress has been associated with poor self-control. Individual differences in impulsivity and other behavioral tendencies may influence the relationship of stress with self-control, although this possibility has not been examined to date. The present research investigated whether cumulative stress is associated with poor self-control, and whether this relationship is mediated by impulsivity, behavioral approach, and behavioral inhibition in men and women. A community sample of 566 adults (319 women and 247 men) was assessed on the Cumulative Adversity Interview, Brief Self-control Scale, Barratt Impulsivity Scale, and Behavioral Activation System and Behavioral Inhibition System Scale (BIS/BAS). Data were analyzed using regression and bootstrapping techniques. In the total sample, the effects of cumulative stress on self-control were mediated by impulsivity. Neither behavioral inhibition nor behavioral approach mediated the association between cumulative stress and self-control in the total sample. Results were similar when men and women were considered separately, with impulsivity, but not behavioral inhibition or approach, mediating the association between cumulative stress and self-control. Impulsive individuals might benefit preferentially from interventions focusing on stress management and strategies for improving self-control. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. [Mes differ by positioning: empirical testing of decentralized dynamics of the self].

    PubMed

    Mizokami, Shinichi

    2013-10-01

    The present study empirically tested the conceptualization of the decentralized dynamics of the self proposed by Hermans & Kempen (1993), which they developed theoretically and from clinical cases, not from large samples of empirical data. They posited that worldviews and images of the self could vary by positioning even in the same individual, and denied that the ego was an omniscient entity that knew and controlled all aspects of the self (centralized ego). Study 1 tested their conceptualization empirically with 47 university students in an experimental group and 17 as a control group. The results showed that the scores on the Rosenberg's self-esteem scale and images of the Mes in the experimental group significantly varied by positioning, but those in the control group did not. Similar results were found in Study 2 with a sample of 120 university students. These results empirically supported the conceptualization of the decentralized dynamics of the self.

  12. Quality-control materials in the USDA National Food and Nutrient Analysis Program (NFNAP).

    PubMed

    Phillips, Katherine M; Patterson, Kristine Y; Rasor, Amy S; Exler, Jacob; Haytowitz, David B; Holden, Joanne M; Pehrsson, Pamela R

    2006-03-01

    The US Department of Agriculture (USDA) Nutrient Data Laboratory (NDL) develops and maintains the USDA National Nutrient Databank System (NDBS). Data are released from the NDBS for scientific and public use through the USDA National Nutrient Database for Standard Reference (SR) ( http://www.ars.usda.gov/ba/bhnrc/ndl ). In 1997 the NDL initiated the National Food and Nutrient Analysis Program (NFNAP) to update and expand its food-composition data. The program included: 1) nationwide probability-based sampling of foods; 2) central processing and archiving of food samples; 3) analysis of food components at commercial, government, and university laboratories; 4) incorporation of new analytical data into the NDBS; and 5) dissemination of these data to the scientific community. A key feature and strength of the NFNAP was a rigorous quality-control program that enabled independent verification of the accuracy and precision of analytical results. Custom-made food-control composites and/or commercially available certified reference materials were sent to the laboratories, blinded, with the samples. Data for these materials were essential to ongoing monitoring of analytical work, to identify and resolve suspected analytical problems, to ensure the accuracy and precision of results for the NFNAP food samples.

  13. Enterovirus RNA in longitudinal blood samples and risk of islet autoimmunity in children with a high genetic risk of type 1 diabetes: the MIDIA study.

    PubMed

    Cinek, Ondrej; Stene, Lars C; Kramna, Lenka; Tapia, German; Oikarinen, Sami; Witsø, Elisabet; Rasmussen, Trond; Torjesen, Peter A; Hyöty, Heikki; Rønningen, Kjersti S

    2014-10-01

    Only a few longitudinal molecular studies of enterovirus and islet autoimmunity have been reported, and positive results seem to be limited to Finland. We aimed to investigate an association between enterovirus RNA in blood and islet autoimmunity in the MIDIA study from Norway, a country which largely shares environmental and economic features with Finland. We analysed serial blood samples collected at ages 3, 6, and 9 months and then annually from 45 children who developed confirmed positivity for at least two autoantibodies (against insulin, GAD65 and IA-2) and 92 matched controls, all from a cohort of children with a single high-risk HLA-DQ-DR genotype. Enterovirus was tested in RNA extracted from frozen blood cell pellets, using real-time RT-PCR with stringent performance control. Out of 807 blood samples, 72 (8.9%) were positive for enterovirus. There was no association between enterovirus RNA and islet autoimmunity in samples obtained strictly before (7.6% cases, 10.0% controls, OR 0.75 [95% CI 0.36, 1.57]), or strictly after the first detection of islet autoantibodies (10.5% case, 5.8% controls, OR 2.00 [95% CI 0.64, 6.27]). However, there was a tendency towards a higher frequency of enterovirus detection in the first islet autoantibody-positive sample (15.8%) compared with the corresponding time point in matched controls (3.2%, OR 8.7 [95% CI 0.97, 77]). Neither of these results was changed by adjusting for potential confounders, restricting to various time intervals or employing various definitions of enterovirus positivity. Positivity for enterovirus RNA in blood did not predict the later induction of islet autoantibodies, but enterovirus tended to be detected more often at the islet autoantibody seroconversion stage.

  14. Development and testing of fiber-reinforced composite space maintainers.

    PubMed

    Kulkarni, Gajanan; Lau, Domenic; Hafezi, Sara

    2009-01-01

    The purpose of this study was to develop a clinically acceptable, cheaper, and more expedient alternative to standard stainless steel band and loop space maintainers. Loops of fiber-reinforced composites were constructed using polyethylene fiber (Ribbond) and glass fiber (Sticktech). The loops were bonded on extracted third molars and tested for flexural strength before and after thermocycling and following repair of the appliances after initial stress failure. Bacterial colonization on the appliances was also compared. Conventional stainless steel band and loop space maintainers cemented with Ketac were controls. Ribbond samples demonstrated higher flexural strength than Sticktech and the control (P<.05). No differences were noted among the other samples and the control. The repaired Ribbond samples were statistically comparable in flexural strength to the initial samples. Thermocycling resulted in decreased flexural strength of both Ribbond and Sticktech (P<.05). Thermocycled Ribbond samples were comparable to the control, but a lower flexural strength was noted for Sticktech samples (P<.05). While all space maintainers allowed some bacterial adhesion, Sticktech showed higher Streptococcus mutans counts than Ribbond (P=.06). Ribbond space-maintainers are comparable to the stainless steel in terms of physical strength and biofilm formation. The fiber-reinforced composite space maintainers may be a clinically acceptable and expedient alternative to the conventional band-loop appliance.

  15. Enhanced Quality Control in Pharmaceutical Applications by Combining Raman Spectroscopy and Machine Learning Techniques

    NASA Astrophysics Data System (ADS)

    Martinez, J. C.; Guzmán-Sepúlveda, J. R.; Bolañoz Evia, G. R.; Córdova, T.; Guzmán-Cabrera, R.

    2018-06-01

    In this work, we applied machine learning techniques to Raman spectra for the characterization and classification of manufactured pharmaceutical products. Our measurements were taken with commercial equipment, for accurate assessment of variations with respect to one calibrated control sample. Unlike the typical use of Raman spectroscopy in pharmaceutical applications, in our approach the principal components of the Raman spectrum are used concurrently as attributes in machine learning algorithms. This permits an efficient comparison and classification of the spectra measured from the samples under study. This also allows for accurate quality control as all relevant spectral components are considered simultaneously. We demonstrate our approach with respect to the specific case of acetaminophen, which is one of the most widely used analgesics in the market. In the experiments, commercial samples from thirteen different laboratories were analyzed and compared against a control sample. The raw data were analyzed based on an arithmetic difference between the nominal active substance and the measured values in each commercial sample. The principal component analysis was applied to the data for quantitative verification (i.e., without considering the actual concentration of the active substance) of the difference in the calibrated sample. Our results show that by following this approach adulterations in pharmaceutical compositions can be clearly identified and accurately quantified.

  16. Validation of internal controls for extraction and amplification of nucleic acids from enteric viruses in water samples.

    PubMed

    Hata, Akihiko; Katayama, Hiroyuki; Kitajima, Masaaki; Visvanathan, Chettiyappan; Nol, Chea; Furumai, Hiroaki

    2011-07-01

    Inhibitors that reduce viral nucleic acid extraction efficiency and interfere with cDNA synthesis and/or polymerase activity affect the molecular detection of viruses in aquatic environments. To overcome these significant problems, we developed a methodology for assessing nucleic acid yields and DNA amplification efficiencies for environmental water samples. This involved adding particles of adenovirus type 5 and murine norovirus and newly developed primer-sharing controls, which are amplified with the same primer pairs and result in the same amplicon sizes as the targets, to these samples. We found that nucleic acid loss during the extraction process, rather than reverse transcription-PCR (RT-PCR) inhibition, more significantly attributed to underestimation of the presence of viral genomes in the environmental water samples tested in this study. Our success rate for satisfactorily amplifying viral RNAs and DNAs by RT-PCR was higher than that for obtaining adequate nucleic acid preparations. We found that inhibitory properties were greatest when we used larger sample volumes. A magnetic silica bead-based RNA extraction method effectively removed inhibitors that interfere with viral nucleic acid extraction and RT-PCR. To our knowledge, this is the first study to assess the inhibitory properties of environmental water samples by using both control virus particles and primer-sharing controls.

  17. Comparison of Control Group Generating Methods.

    PubMed

    Szekér, Szabolcs; Fogarassy, György; Vathy-Fogarassy, Ágnes

    2017-01-01

    Retrospective studies suffer from drawbacks such as selection bias. As the selection of the control group has a significant impact on the evaluation of the results, it is very important to find the proper method to generate the most appropriate control group. In this paper we suggest two nearest neighbors based control group selection methods that aim to achieve good matching between the individuals of case and control groups. The effectiveness of the proposed methods is evaluated by runtime and accuracy tests and the results are compared to the classical stratified sampling method.

  18. Comparison of Individual and Pooled Stool Samples for the Assessment of Soil-Transmitted Helminth Infection Intensity and Drug Efficacy

    PubMed Central

    Mekonnen, Zeleke; Meka, Selima; Ayana, Mio; Bogers, Johannes; Vercruysse, Jozef; Levecke, Bruno

    2013-01-01

    Background In veterinary parasitology samples are often pooled for a rapid assessment of infection intensity and drug efficacy. Currently, studies evaluating this strategy in large-scale drug administration programs to control human soil-transmitted helminths (STHs; Ascaris lumbricoides, Trichuris trichiura, and hookworm), are absent. Therefore, we developed and evaluated a pooling strategy to assess intensity of STH infections and drug efficacy. Methods/Principal Findings Stool samples from 840 children attending 14 primary schools in Jimma, Ethiopia were pooled (pool sizes of 10, 20, and 60) to evaluate the infection intensity of STHs. In addition, the efficacy of a single dose of mebendazole (500 mg) in terms of fecal egg count reduction (FECR; synonym of egg reduction rate) was evaluated in 600 children from two of these schools. Individual and pooled samples were examined with the McMaster egg counting method. For each of the three STHs, we found a significant positive correlation between mean fecal egg counts (FECs) of individual stool samples and FEC of pooled stool samples, ranging from 0.62 to 0.98. Only for A. lumbricoides was any significant difference in mean FEC of the individual and pooled samples found. For this STH species, pools of 60 samples resulted in significantly higher FECs. FECR for the different number of samples pooled was comparable in all pool sizes, except for hookworm. For this parasite, pools of 10 and 60 samples provided significantly higher FECR results. Conclusion/Significance This study highlights that pooling stool samples holds promise as a strategy for rapidly assessing infection intensity and efficacy of administered drugs in programs to control human STHs. However, further research is required to determine when and how pooling of stool samples can be cost-effectively applied along a control program, and to verify whether this approach is also applicable to other NTDs. PMID:23696905

  19. Effects of long term space environment exposure on optical substrates and coatings (S0050-2)

    NASA Technical Reports Server (NTRS)

    Harvey, Keith; Mustico, Arthur; Vallimont, John

    1993-01-01

    Eastman Kodak Company included twelve substrate and coating samples on the Long Duration Exposure Facility (LDEF) structure. There were three Fused Silica and three Ultra Low Expansion (ULE) uncoated glass samples, two ULE samples with a high reflectance silver coating, two Fused Silica samples with an antireflectance coating, and two Fused silica samples with a solar rejection coating. A set of duplicate control samples was also manufactured and stored in a controlled environment for comparison purposes. Kodak's samples were included as a subset of the Georgia Institute of Technology tray, which was located on row 5-E, tray S0050-2. This placed the samples on the trailing edge of the structure, which protected them from the effects of atomic oxygen bombardment. An evaluation of the flight samples for effects from the 5 year mission showed that a contaminant was deposited on the samples, a micrometeoroid impact occurred on one of the samples, and the radiation darkening which was expected for the glass did not occur. The results are listed in more detail.

  20. Differences in fungi present in induced sputum samples from asthma patients and non-atopic controls: a community based case control study

    PubMed Central

    2013-01-01

    Background There is emerging evidence for the presence of an extensive microbiota in human lungs. It is not known whether variations in the prevalence of species of microbiota in the lungs may have aetiological significance in respiratory conditions such as asthma. The aim of the study was to undertake semi-quantitative analysis of the differences in fungal species in pooled sputum samples from asthma patients and controls. Methods Induced sputum samples were collected in a case control study of asthma patients and control subjects drawn from the community in Wandsworth, London. Samples from both groups were pooled and then tested for eukaryotes. DNA was amplified using standard PCR techniques, followed by pyrosequencing and comparison of reads to databases of known sequences to determine in a semi-quantitative way the percentage of DNA from known species in each of the two pooled samples. Results A total of 136 fungal species were identified in the induced sputum samples, with 90 species more common in asthma patients and 46 species more common in control subjects. Psathyrella candolleana, Malassezia pachydermatis, Termitomyces clypeatus and Grifola sordulenta showed a higher percentage of reads in the sputum of asthma patients and Eremothecium sinecaudum, Systenostrema alba, Cladosporium cladosporioides and Vanderwaltozyma polyspora showed a higher percentage of reads in the sputum of control subjects. A statistically significant difference in the pattern of fungi that were present in the respective samples was demonstrated using the Phylogenetic (P) test (P < 0.0001). Conclusion This study is novel in providing evidence for the widespread nature of fungi in the sputum of healthy and asthmatic individuals. Differences in the pattern of fungi present in asthma patients and controls merit further investigation. Of particular interest was the presence of Malassezia pachydermatis, which is known to be associated with atopic dermatitis. PMID:23384395

  1. Optimizing methods and dodging pitfalls in microbiome research.

    PubMed

    Kim, Dorothy; Hofstaedter, Casey E; Zhao, Chunyu; Mattei, Lisa; Tanes, Ceylan; Clarke, Erik; Lauder, Abigail; Sherrill-Mix, Scott; Chehoud, Christel; Kelsen, Judith; Conrad, Máire; Collman, Ronald G; Baldassano, Robert; Bushman, Frederic D; Bittinger, Kyle

    2017-05-05

    Research on the human microbiome has yielded numerous insights into health and disease, but also has resulted in a wealth of experimental artifacts. Here, we present suggestions for optimizing experimental design and avoiding known pitfalls, organized in the typical order in which studies are carried out. We first review best practices in experimental design and introduce common confounders such as age, diet, antibiotic use, pet ownership, longitudinal instability, and microbial sharing during cohousing in animal studies. Typically, samples will need to be stored, so we provide data on best practices for several sample types. We then discuss design and analysis of positive and negative controls, which should always be run with experimental samples. We introduce a convenient set of non-biological DNA sequences that can be useful as positive controls for high-volume analysis. Careful analysis of negative and positive controls is particularly important in studies of samples with low microbial biomass, where contamination can comprise most or all of a sample. Lastly, we summarize approaches to enhancing experimental robustness by careful control of multiple comparisons and to comparing discovery and validation cohorts. We hope the experimental tactics summarized here will help researchers in this exciting field advance their studies efficiently while avoiding errors.

  2. Drug Loading Capacity of Environmentally Sensitive Polymeric Microgels

    NASA Astrophysics Data System (ADS)

    McDonough, Ryan; Streletzky, Kiril; Bayachou, Mekki; Peiris, Pubudu

    2009-10-01

    Microgel nanoparticles consisting of cross-linked polymer hydroxypropyl cellulose chains have a temperature dependent volume phase transition, prompting the use of microgels for controlled drug transport. Drug particles aggregate in the slightly hydrophobic interior of microgels. Microgels are stored in equilibrium until the critical temperature (Tv) is reached and the volume phase transition limits available space, thus expelling the drugs. Our study was designed to test this property of microgels using amperometric electrochemical methods. A critical assumption was that small molecules inside microgels would not interact via diffusion with the electrode surface and thus total current would be decreased across the electrodes in a microgel sample. A room temperature (Troom) flow amperometric measurement comparing microgel/tylenol solution with control tylenol samples yielded about 20% tylenol concentration reduction of the microgel sample. Results from the steady state electrochemical experiment confirm the presence of about 20% tylenol concentration drop of the microgel sample compared to control sample at Troom. Using the steady-state experiment with a cyclic temperature ramp from Troom to beyond Tv showed that the tylenol concentration change between the temperature extremes was greater for the microgel solution than for the control solution.

  3. Evaluation of Quality-Assurance/Quality-Control Data Collected by the U.S. Geological Survey from Wells and Springs between the Southern Boundary of the Idaho National Engineering and Environmental Laboratory and the Hagerman Area, Idaho, 1989 through 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, L.M.; Bartholomay, R.C.; Campbell, L.J.

    1998-10-01

    The U.S. Geological (USGS) and the Idaho Department of Water Resources, in cooperation with the U.S. Department of Energy, collected and analyzed water samples to monitor the water quality of the Snake River Plain aquifer from the southern boundary of the Idaho National Engineering and Environmental Laboratory to the Hagerman area, Idaho. Concurrently, replicate samples and blank samples were collected and analyzed as part of the quality-assurance/quality-control program. Samples were analyzed from inorganic constituents, gross radioactivity and radionuclides, organic constituents, and stable isotopes. To evaluate the precision of field and laboratory methods, analytical results of the water-quality and replicate samplesmore » were compared statistically for equivalence on the basis of the precision associated with each result. Statistical comparisons of the data indicated that 95 percent of the results of the replicate pairs were equivalent. Blank-sample analytical results indicated th at the inorganic blank water and volatile organic compound blank water from the USGS National Water Quality Laboratory and the distilled water from the Idaho Department of Water Resources were suitable for blanks; blank water from other sources was not. Equipment-blank analytical results were evaluated to determine if a bias had been introduced and possible sources of bias. Most equipment blanks were analyzed for trace elements and volatile organic compounds; chloroform was found in one equipment blank. Two of the equipment blanks were prepared after collection and analyses of the water-quality samples to determine whether contamination had been introduced during the sampling process. Results of one blank indicated that a hose used to divert water away from pumps and electrical equipment had contaminated the samples with some volatile organic compounds. Results of the other equipment blank, from the apparatus used to filter dissolved organic carbon samples, indicated that the filtering apparatus did not affect water-quality samples.« less

  4. Absence of bacterial DNA in culture-negative urine from cats with and without lower urinary tract disease.

    PubMed

    Lund, Heidi Sjetne; Skogtun, Gaute; Sørum, Henning; Eggertsdóttir, Anna Vigdís

    2015-10-01

    A diagnosis of bacterial cystitis commonly relies on a positive microbiological culture demonstrating the presence of a significant number of colony-forming units/ml urine, as urine within the upper urinary tract, bladder and proximal urethra generally is considered sterile. Recent studies from human and veterinary medicine indicate the presence of non-culturable bacteria in culture-negative urine samples. The aim of the present study was to determine the occurrence of bacterial DNA in culture-negative urine samples from cats with signs of feline lower urinary tract disease (FLUTD) and healthy control cats by 16S ribosomal DNA PCR and subsequent sequencing. The study sample included 38 culture-negative urine samples from cats with FLUTD and 43 culture-negative samples from control cats. Eight culture-positive urine samples from cats with FLUTD were included as external positive controls in addition to negative reaction controls. Of possible methodological limitations, degradation of DNA due to storage, the use of non-sedimented urine for DNA isolation and lack of internal positive reaction controls should be mentioned. The positive controls were recognised, but occurrence of bacterial DNA in culture-negative urine from cats with or without signs of lower urinary tract disease was not demonstrated. However, considering the possible methodological limitations, the presence of bacterial DNA in the urine of culture-negative FLUTD cats cannot be excluded based on the present results alone. Therefore, a prospective study reducing the possibility of degradation of DNA due to storage, in combination with modifications enhancing the chance of detecting even lower levels of bacterial DNA in culture-negative samples, seems warranted. © ISFM and AAFP 2014.

  5. Quasi-elastic light scattering: Signal storage, correlation, and spectrum analysis under control of an 8-bit microprocessor

    NASA Astrophysics Data System (ADS)

    Glatter, Otto; Fuchs, Heribert; Jorde, Christian; Eigner, Wolf-Dieter

    1987-03-01

    The microprocessor of an 8-bit PC system is used as a central control unit for the acquisition and evaluation of data from quasi-elastic light scattering experiments. Data are sampled with a width of 8 bits under control of the CPU. This limits the minimum sample time to 20 μs. Shorter sample times would need a direct memory access channel. The 8-bit CPU can address a 64-kbyte RAM without additional paging. Up to 49 000 sample points can be measured without interruption. After storage, a correlation function or a power spectrum can be calculated from such a primary data set. Furthermore access is provided to the primary data for stability control, statistical tests, and for comparison of different evaluation methods for the same experiment. A detailed analysis of the signal (histogram) and of the effect of overflows is possible and shows that the number of pulses but not the number of overflows determines the error in the result. The correlation function can be computed with reasonable accuracy from data with a mean pulse rate greater than one, the power spectrum needs a three times higher pulse rate for convergence. The statistical accuracy of the results from 49 000 sample points is of the order of a few percent. Additional averages are necessary to improve their quality. The hardware extensions for the PC system are inexpensive. The main disadvantage of the present system is the high minimum sampling time of 20 μs and the fact that the correlogram or the power spectrum cannot be computed on-line as it can be done with hardware correlators or spectrum analyzers. These shortcomings and the storage size restrictions can be removed with a faster 16/32-bit CPU.

  6. The effects of subjective loss of control on risk-taking behavior: the mediating role of anger

    PubMed Central

    Beisswingert, Birgit M.; Zhang, Keshun; Goetz, Thomas; Fang, Ping; Fischbacher, Urs

    2015-01-01

    Based on the Appraisal Tendency Framework on the antecedents and consequences of emotions two experimental studies examined the relationship between externally caused loss of control experiences and risk-taking behavior, as well as the assumed mediation of this relationship by the emotion anger. An experimental paradigm for inducing externally caused and consequently externally attributed loss of control which should lead to experiences of anger was developed and pretested in a Pilot Study. The relationship between loss of control experiences, anger, and risk-taking behavior was investigated using two separate student samples from Germany (N = 84, 54% female) and China (N = 125; 64% female). In line with our hypotheses, results showed that anger mediated the link between subjective loss of control experiences and increasing risk-taking behavior. Multiple group comparisons revealing similar patterns in both samples affirmed the results’ cross-cultural generalizability. These results implicate that anger makes people less risk averse in the process of economic decision making. PMID:26217244

  7. Interleukin 1 beta gene and risk of schizophrenia: detailed case-control and family-based studies and an updated meta-analysis.

    PubMed

    Shibuya, Masako; Watanabe, Yuichiro; Nunokawa, Ayako; Egawa, Jun; Kaneko, Naoshi; Igeta, Hirofumi; Someya, Toshiyuki

    2014-01-01

    Interleukin-1 beta (IL-1β) has been implicated in the pathophysiology of schizophrenia. To assess whether the IL1B gene confers increased susceptibility to schizophrenia, we conducted case-control and family-based studies and an updated meta-analysis. We tested the association between IL1B and schizophrenia in 1229 case-control and 112 trio samples using 12 markers, including common tagging single nucleotide variations (SNVs) and a rare non-synonymous variation detected by resequencing the coding regions. We also performed a meta-analysis of rs16944 using a total of 8724 case-control and 201 trio samples from 16 independent populations. We found no significant associations between any of the 12 SNVs examined and schizophrenia in either case-control or trio samples. Moreover, our meta-analysis results showed no significant association between the common SNV, rs16944, and schizophrenia. The present study does not support a role for IL1B in schizophrenia susceptibility.

  8. Resource recovery from septic tank effluent using duckweed-based tilapia aquaculture.

    PubMed

    El-Shafai, Saber A; Abdel-Gawad, Fagr Kh; Samhan, Farag; Nasr, Fayza A

    2013-01-01

    Two parallel duckweed ponds were deployed to utilize nutrients from the effluent of a septic tank treating domestic wastewater. The effluent and fresh biomass of duckweed pond were fed to two subsequent fish ponds stocked with Nile tilapia (Oreochromis niloticus). Fish ponds receiving freshwater and commercial feed were used as control. The results of specific growth rate and feed conversion ratio showed no significant difference between the control ponds and treatment ponds. On the other hand, the total and net fish yields were significantly higher in the control. Microbial analysis revealed contamination of gills, intestine and liver of fish in the treatment ponds. The activity of the immune response genes was up-regulated in the brain and liver of the treatment samples. A micronucleus assay revealed a similar percentage of micronuclei in the polychromatic erythrocytes of blood in the control and treatment samples, while the treatment samples a had higher incidence of micronuclei in the polychromatic erythrocytes of gills, compared with the control.

  9. Metabolomics Characterization of U.S. and Japanese F-15 and C-130 Flight Line Crews Exposed to Jet Fuel Volatile Organic Compounds and Aerosols

    DTIC Science & Technology

    2014-09-30

    resulted in the identification of metabolite patterns indicative of flight line exposure when compared to non -flight line control subjects...virtually non -invasive sample collection, minimal sample processing, robust and stable analytical platform, with excellent analytical and biological...identification of metabolite patterns indicative of flight line exposure when compared to non -flight line control subjects. Regardless of fuel (JP-4 or

  10. Distribution of copper, iron, and zinc in biological samples (scalp hair, serum, blood, and urine) of Pakistani viral hepatitis (A-E) patients and controls.

    PubMed

    Kolachi, Nida Fatima; Kazi, Tasneem Gul; Afridi, Hassan Imran; Kazi, Naveed; Kandhro, Ghulam Abbas; Shah, Abdul Qadir; Baig, Jameel Ahmed; Wadhwa, Sham Kumar; Khan, Sumaira; Shah, Faheem; Jamali, Mohammad Khan; Arain, Mohammad Balal

    2011-10-01

    The aim of the present study was to compare the level of copper (Cu), iron (Fe) and zinc (Zn) in biological samples (serum, blood, urine, and scalp hair) of patients suffering from different viral hepatitis (A, B, C, D, and E; n = 521) of both gender age ranged 31-45 years. For comparative study, 255 age-matched control subjects, of both genders residing in the same city were selected as referents. The elements in the biological samples were analyzed by flame atomic absorption spectrophotometry, prior to microwave-assisted acid digestion. The validity and accuracy of the methodology was checked by using certified reference materials (CRMs) and with those values obtained by conventional wet acid digestion method on same CRMs. The results of this study showed that the mean values of Cu and Fe were higher in blood, sera, and scalp hair samples of hepatitis patients, while Zn level was found to be lower than age-matched control subjects. The urinary levels of these elements were found to be higher in the hepatitis patients than in the age-matched healthy controls (p < 0.05). These results are consistent with literature-reported data, confirming that the deficiency of zinc and hepatic iron and copper overload can directly cause lipid peroxidation and eventually hepatic damage.

  11. An integrated microfluidic analysis microsystems with bacterial capture enrichment and in-situ impedance detection

    NASA Astrophysics Data System (ADS)

    Liu, Hai-Tao; Wen, Zhi-Yu; Xu, Yi; Shang, Zheng-Guo; Peng, Jin-Lan; Tian, Peng

    2017-09-01

    In this paper, an integrated microfluidic analysis microsystems with bacterial capture enrichment and in-situ impedance detection was purposed based on microfluidic chips dielectrophoresis technique and electrochemical impedance detection principle. The microsystems include microfluidic chip, main control module, and drive and control module, and signal detection and processing modulet and result display unit. The main control module produce the work sequence of impedance detection system parts and achieve data communication functions, the drive and control circuit generate AC signal which amplitude and frequency adjustable, and it was applied on the foodborne pathogens impedance analysis microsystems to realize the capture enrichment and impedance detection. The signal detection and processing circuit translate the current signal into impendence of bacteria, and transfer to computer, the last detection result is displayed on the computer. The experiment sample was prepared by adding Escherichia coli standard sample into chicken sample solution, and the samples were tested on the dielectrophoresis chip capture enrichment and in-situ impedance detection microsystems with micro-array electrode microfluidic chips. The experiments show that the Escherichia coli detection limit of microsystems is 5 × 104 CFU/mL and the detection time is within 6 min in the optimization of voltage detection 10 V and detection frequency 500 KHz operating conditions. The integrated microfluidic analysis microsystems laid the solid foundation for rapid real-time in-situ detection of bacteria.

  12. Industrial Raman gas sensing for real-time system control

    NASA Astrophysics Data System (ADS)

    Buric, M.; Mullen, J.; Chorpening, B.; Woodruff, S.

    2014-06-01

    Opportunities exist to improve on-line process control in energy applications with a fast, non-destructive measurement of gas composition. Here, we demonstrate a Raman sensing system which is capable of reporting the concentrations of numerous species simultaneously with sub-percent accuracy and sampling times below one-second for process control applications in energy or chemical production. The sensor is based upon a hollow-core capillary waveguide with a 300 micron bore with reflective thin-film metal and dielectric linings. The effect of using such a waveguide in a Raman process is to integrate Raman photons along the length of the sample-filled waveguide, thus permitting the acquisition of very large Raman signals for low-density gases in a short time. The resultant integrated Raman signals can then be used for quick and accurate analysis of a gaseous mixture. The sensor is currently being tested for energy applications such as coal gasification, turbine control, well-head monitoring for exploration or production, and non-conventional gas utilization. In conjunction with an ongoing commercialization effort, the researchers have recently completed two prototype instruments suitable for hazardous area operation and testing. Here, we report pre-commercialization testing of those field prototypes for control applications in gasification or similar processes. Results will be discussed with respect to accuracy, calibration requirements, gas sampling techniques, and possible control strategies of industrial significance.

  13. [Sampling in quality control of medicinal materials-A case of Epimedium].

    PubMed

    Wang, Chuanyi; Cao, Jinyi; Liang, Yun; Huang, Wenhua; Guo, Baolin

    2009-04-01

    To investigate the effect of the different individual number of sampling on the assay results of the medicinal materials. Epimedium pubescens and E. brevicornu were used as samples. The 6 sampling levels were formulated as 1 individual, 5, 10, 20, 30, 50 individuals mix, each level with 3 parallels and 1 individual level5 parallels. The contents of epimedin C and icariin, and the peak areas of epimedin A, epimedin B, rhamnosyl icarisid II and icarisid II in all samples were analyzed by HPLC. The variation degree varied with species and chemical constituents, but the RSD and the deviation from the true value decreased with the increase of individual number on the same chemical constituent. The sampling number should be more than 10 individuals in quality control of Epimedium, and 50 or more individuals would be better for representing the quality of medicinal materials.

  14. New Noble Gas Studies on Popping Rocks from the Mid-Atlantic Ridge near 14°N

    NASA Astrophysics Data System (ADS)

    Kurz, M. D.; Curtice, J.; Jones, M.; Péron, S.; Wanless, V. D.; Mittelstaedt, E. L.; Soule, S. A.; Klein, F.; Fornari, D. J.

    2017-12-01

    New Popping Rocks were recovered in situ on the Mid-Atlantic Ridge (MAR) near 13.77° N, using HOV Alvin on cruise AT33-03 in 2016 on RV Atlantis. We report new helium, neon, argon, and CO2 step-crushing measurements on a subset of the glass samples, with a focus on a new procedure to collect seafloor samples with minimal exposure to air. Glassy seafloor basalts were collected in sealed containers using the Alvin mechanical arm and transported to the surface without atmospheric exposure. On the ship, the seawater was drained, the volcanic glass was transferred to stainless steel ultra-high-vacuum containers (in an oxygen-free glove box), which were then evacuated using a turbo-molecular pump and sealed for transport under vacuum. All processing was carried out under a nitrogen atmosphere. A control sample was collected from each pillow outcrop and processed normally in air. The preliminary step-crushing measurements show that the anaerobically collected samples have systematically higher 20Ne/22Ne, 21Ne/22Ne and 40Ar/36Ar than the control samples. Helium abundances and isotopes are consistent between anaerobically collected samples and control samples. These results suggest that minimizing atmospheric exposure during sample processing can significantly reduce air contamination for heavy noble gases, providing a new option for seafloor sampling. Higher vesicle abundances appear to yield a greater difference in neon and argon isotopes between the anaerobic and control samples, suggesting that atmospheric contamination is related to vesicle abundance, possibly through micro-fractures. The new data show variability in the maximum mantle neon and argon isotopic compositions, and abundance ratios, suggesting that the samples experienced variable outgassing prior to eruption, and may represent different phases of a single eruption, or multiple eruptions.

  15. A novel condition for stable nonlinear sampled-data models using higher-order discretized approximations with zero dynamics.

    PubMed

    Zeng, Cheng; Liang, Shan; Xiang, Shuwen

    2017-05-01

    Continuous-time systems are usually modelled by the form of ordinary differential equations arising from physical laws. However, the use of these models in practice and utilizing, analyzing or transmitting these data from such systems must first invariably be discretized. More importantly, for digital control of a continuous-time nonlinear system, a good sampled-data model is required. This paper investigates the new consistency condition which is weaker than the previous similar results presented. Moreover, given the stability of the high-order approximate model with stable zero dynamics, the novel condition presented stabilizes the exact sampled-data model of the nonlinear system for sufficiently small sampling periods. An insightful interpretation of the obtained results can be made in terms of the stable sampling zero dynamics, and the new consistency condition is surprisingly associated with the relative degree of the nonlinear continuous-time system. Our controller design, based on the higher-order approximate discretized model, extends the existing methods which mainly deal with the Euler approximation. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  16. Event-triggered synchronization for reaction-diffusion complex networks via random sampling

    NASA Astrophysics Data System (ADS)

    Dong, Tao; Wang, Aijuan; Zhu, Huiyun; Liao, Xiaofeng

    2018-04-01

    In this paper, the synchronization problem of the reaction-diffusion complex networks (RDCNs) with Dirichlet boundary conditions is considered, where the data is sampled randomly. An event-triggered controller based on the sampled data is proposed, which can reduce the number of controller and the communication load. Under this strategy, the synchronization problem of the diffusion complex network is equivalently converted to the stability of a of reaction-diffusion complex dynamical systems with time delay. By using the matrix inequality technique and Lyapunov method, the synchronization conditions of the RDCNs are derived, which are dependent on the diffusion term. Moreover, it is found the proposed control strategy can get rid of the Zeno behavior naturally. Finally, a numerical example is given to verify the obtained results.

  17. Evaluation of the use of pooled serum, pooled muscle tissue fluid (meat juice) and pooled faeces for monitoring pig herds for Salmonella.

    PubMed

    Davies, R H; Heath, P J; Coxon, S M; Sayers, A R

    2003-01-01

    Monitoring for Salmonella in slaughter pigs is important to enable targeted control measures to be applied on problem farms and at the abattoir. The aim of this study was to determine whether pooled serum and meat juice could be used to identify finishing pig herds with a high prevalence of infection. Samples of meat juice, serum, caecal contents, carcase swabs and pooled faeces from pig pens were taken from 20 commercial pig finishing farms and comparisons were made between the results of Salmonella culture, individual ELISA tests on serum and meat juice and pooled samples of serum and meat juice. Salmonella was isolated from samples from 19 of 20 farms. None of the ELISA tests showed a statistically significant correlation with caecal carriage of Salmonella or contamination of carcases. Serum mean optical density (O.D.) from pools of five, 10 or 20 sera showed a significant correlation with the Salmonella status of farm pen faeces. All pooled serum O.D. and sample/positive control ratio results correlated significantly with the results of the conventional individual sample ELISA. There was a statistically significant correlation between the incidence of Salmonella in farm pen pooled faeces and the prevalence of Salmonella in caeca of slaughter pigs. The results show a generally poor correlation between serological and bacteriological results but pooled serum or meat juice samples could be used as a cheaper substitute for serological screening of farms for Salmonella than individual samples. The availability of a cheaper test should allow the costs of Salmonella monitoring of pig farms to be reduced or allow more regular testing to enhance the designation of farm Salmonella risk status.

  18. Analysis of tank 7 surface supernatant sample (FTF-7-15-26) in support of corrosion control program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oji, L. N

    2015-10-01

    This report provides the results of analyses on Savannah River Site Tank 7 surface supernatant liquid sample in support of the Corrosion Control Program (CCP). The measured nitrate, nitrite and free-hydroxide concentrations for the Tank 7 surface sample averaged, 3.74E-01 ± 1.88E-03, 4.17E-01 ± 9.01E-03 and 0.602 ± 0.005 M, respectively. The Tank 7 surface cesium-137, sodium and silicon concentrations were, respectively, 3.99E+08, ± 3.25E+06 dpm/mL, 2.78 M and <3.10 mg/L. The measured aluminum concentration in the Tank 7 surface sample averaged 0.11 M.

  19. Method of Analysis by the U.S. Geological Survey California District Sacramento Laboratory-- Determination of Dissolved Organic Carbon in Water by High Temperature Catalytic Oxidation, Method Validation, and Quality-Control Practices

    USGS Publications Warehouse

    Bird, Susan M.; Fram, Miranda S.; Crepeau, Kathryn L.

    2003-01-01

    An analytical method has been developed for the determination of dissolved organic carbon concentration in water samples. This method includes the results of the tests used to validate the method and the quality-control practices used for dissolved organic carbon analysis. Prior to analysis, water samples are filtered to remove suspended particulate matter. A Shimadzu TOC-5000A Total Organic Carbon Analyzer in the nonpurgeable organic carbon mode is used to analyze the samples by high temperature catalytic oxidation. The analysis usually is completed within 48 hours of sample collection. The laboratory reporting level is 0.22 milligrams per liter.

  20. 210Po secretion from sweat glands.

    PubMed

    Romańczyk, Grzegorz; Boryło, Alicja

    2017-02-01

    The results of the research indicated that the 210 Po activity concentration in sweat samples was between 0.22 ± 0.03 to 2.10 ± 0.15 mBq·g -1 d.w. The obtained results of the studies showed that smoking and eating fish led to higher activity concentrations of 210 Po in sweat in comparison to the control group. Statistical analysis of 210 Po activity concentrations in sweat samples showed significant differences between control, smoking, fish eating and age groups, while no significant differences was found for 210 Po between volunteers as far as gender is concerned. Copyright © 2016. Published by Elsevier Ltd.

  1. The stressed student: influence of written examinations and oral presentations on salivary cortisol concentrations in university students.

    PubMed

    Preuss, Diana; Schoofs, Daniela; Schlotz, Wolff; Wolf, Oliver T

    2010-05-01

    Laboratory research has demonstrated that social-evaluative threat has an influence on the hypothalamus pituitary adrenal axis (HPA). In two studies using independent samples, we evaluated the anticipatory cortisol response to a written university examination (n = 35) and to an oral presentation (n = 34). Saliva samples were collected before and after the examinations and on a control day. Additionally, saliva samples were collected on the day before the written examination and a control day. Results revealed significantly elevated cortisol concentrations on the day prior to the examination; however, this effect occurred only in those participants who had their control day after the examination. Cortisol concentrations were elevated on the examination day, with increased concentrations before but not after the examination. For the oral presentation study, the results revealed substantially elevated cortisol concentrations before and after the oral presentation. Taken together the results indicate that written examinations cause a mild anticipatory HPA response while oral presentations induce a strong HPA response. These findings appear to support the idea that social-evaluative threat is an important factor determining the size of the HPA response to laboratory stressors as well as to real-life stressors.

  2. Solid state electro-optic color filter and iris

    NASA Technical Reports Server (NTRS)

    1974-01-01

    Test results obtained have confirmed the practicality of the solid state electro-optic filters as an optical control element in a television system. Neutral-density control range in excess of 1000:1 has been obtained on sample filters. Test results, measurements in a complete camera system, discussions of problem areas, analytical comparisons, and recommendations for future investigations are included.

  3. Airborne concentrations of methylene diphenyl diisocyanate (MDI) in North American wood mills during the manufacturing of oriented strand board (OSB).

    PubMed

    Karoly, William J; Flatley, John J; Stevenson, Ralph D; Bowers, John D

    2004-12-01

    Air monitoring data were collected from industrial hygiene surveys over an 8-year period in oriented strand board (OSB) mills. Personal samples were taken to evaluate potential employee exposures to MDI. Area samples were taken to determine the effectiveness of control measures used in the mills to prevent fugitive emissions of wood dust, MDI, and MDI-coated wood dust from the OSB manufacturing process. Personal sampling results (578 samples covering 11 different job categories) ranged from 0.0002-0.524 mg/m3, with a GM = 0.001 and GSD = 3.71. Area sampling results (1657 samples covering 14 stationary locations in the mills) ranged from 0.0002-2.5 mg/m3, with a GM = 0.004 and GSD = 5.52. The statistical range of the data suggests high variability. While exposures to MDI above the established limits (0.051 mg/m3, 8-hour time-weighted average, 0.2 mg/m3, ceiling) can and do occur when engineering controls are not maintained and/or proper work practices and personal protective equipment are not followed/used for certain high exposure potential tasks, the data indicate that over 97% of the personal and 92% of the area sampling results are less than 0.051 mg/m3. Wipe testing was performed to determine the presence of removable, unreacted diisocyanates (NCO functional groups)from various surfaces. Positive results were found in about 13% of the wipe tests on surfaces confined to the blender, forming line, and hopper deck process areas.

  4. The Influence of trisomy 21 on facial form and variability.

    PubMed

    Starbuck, John M; Cole, Theodore M; Reeves, Roger H; Richtsmeier, Joan T

    2017-11-01

    Triplication of chromosome 21 (trisomy 21) results in Down syndrome (DS), the most common live-born human aneuploidy. Individuals with DS have a unique facial appearance that can include form changes and altered variability. Using 3D photogrammatic images, 3D coordinate locations of 20 anatomical landmarks, and Euclidean Distance Matrix Analysis methods, we quantitatively test the hypothesis that children with DS (n = 55) exhibit facial form and variance differences relative to two different age-matched (4-12 years) control samples of euploid individuals: biological siblings of individuals with DS (n = 55) and euploid individuals without a sibling with DS (n = 55). Approximately 36% of measurements differ significantly between DS and DS-sibling samples, whereas 46% differ significantly between DS and unrelated control samples. Nearly 14% of measurements differ significantly in variance between DS and DS sibling samples, while 18% of measurements differ significantly in variance between DS and unrelated euploid control samples. Of those measures that showed a significant difference in variance, all were relatively increased in the sample of DS individuals. These results indicate that faces of children with DS are quantitatively more similar to their siblings than to unrelated euploid individuals and exhibit consistent, but slightly increased variation with most individuals falling within the range of normal variation established by euploid samples. These observations provide indirect evidence of the strength of the genetic underpinnings of the resemblance between relatives and the resistance of craniofacial development to genetic perturbations caused by trisomy 21, while underscoring the complexity of the genotype-phenotype map. © 2017 Wiley Periodicals, Inc.

  5. FT-IR spectroscopy and multivariate analysis as an auxiliary tool for diagnosis of mental disorders: Bipolar and schizophrenia cases

    NASA Astrophysics Data System (ADS)

    Ogruc Ildiz, G.; Arslan, M.; Unsalan, O.; Araujo-Andrade, C.; Kurt, E.; Karatepe, H. T.; Yilmaz, A.; Yalcinkaya, O. B.; Herken, H.

    2016-01-01

    In this study, a methodology based on Fourier-transform infrared spectroscopy and principal component analysis and partial least square methods is proposed for the analysis of blood plasma samples in order to identify spectral changes correlated with some biomarkers associated with schizophrenia and bipolarity. Our main goal was to use the spectral information for the calibration of statistical models to discriminate and classify blood plasma samples belonging to bipolar and schizophrenic patients. IR spectra of 30 samples of blood plasma obtained from each, bipolar and schizophrenic patients and healthy control group were collected. The results obtained from principal component analysis (PCA) show a clear discrimination between the bipolar (BP), schizophrenic (SZ) and control group' (CG) blood samples that also give possibility to identify three main regions that show the major differences correlated with both mental disorders (biomarkers). Furthermore, a model for the classification of the blood samples was calibrated using partial least square discriminant analysis (PLS-DA), allowing the correct classification of BP, SZ and CG samples. The results obtained applying this methodology suggest that it can be used as a complimentary diagnostic tool for the detection and discrimination of these mental diseases.

  6. Results of the Excreta Bioassay Quality Control Program for April 1, 2009 through March 31, 2010

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Antonio, Cheryl L.

    2012-07-19

    A total of 58 urine samples and 10 fecal samples were submitted during the report period (April 1, 2009 through March 31, 2010) to General Engineering Laboratories, South Carolina by the Hanford Internal Dosimetry Program (IDP) to check the accuracy, precision, and detection levels of their analyses. Urine analyses for Sr, 238Pu, 239Pu, 241Am, 243Am 235U, 238U, elemental uranium and fecal analyses for 241Am, 238Pu and 239Pu were tested this year as well as four tissue samples for 238Pu, 239Pu, 241Am and 241Pu. The number of QC urine samples submitted during the report period represented 1.3% of the total samplesmore » submitted. In addition to the samples provided by IDP, GEL was also required to conduct their own QC program, and submit the results of analyses to IDP. About 33% of the analyses processed by GEL during the third year of this contract were quality control samples. GEL tested the performance of 21 radioisotopes, all of which met or exceeded the specifications in the Statement of Work within statistical uncertainty (Table 4).« less

  7. Results of The Excreta Bioassay Quality Control Program For April 1, 2010 Through March 31, 2011

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Antonio, Cheryl L.

    2012-07-19

    A total of 76 urine samples and 10 spiked fecal samples were submitted during the report period (April 1, 2010 through March 31, 2011) to GEL Laboratories, LLC in South Carolina by the Hanford Internal Dosimetry Program (IDP) to check the accuracy, precision, and detection levels of their analyses. Urine analyses for 14C, Sr, for 238Pu, 239Pu, 241Am, 243Am, 235U, 238U, 238U-mass and fecal analyses for 241Am, 238Pu and 239Pu were tested this year. The number of QC urine samples submitted during the report period represented 1.1% of the total samples submitted. In addition to the samples provided by IDP,more » GEL was also required to conduct their own QC program, and submit the results of analyses to IDP. About 31% of the analyses processed by GEL during the first year of contract 112512 were quality control samples. GEL tested the performance of 23 radioisotopes, all of which met or exceeded the specifications in the Statement of Work within statistical uncertainty except the slightly elevated relative bias for 243,244Cm (Table 4).« less

  8. Introduction of a rapid, simple radioimmunoassay and quality control scheme for thyroxine.

    PubMed Central

    Nye, L; Hassan, M; Willmott, E; Landon, J

    1976-01-01

    A simple radioimmunoassay has been developed for service purposes to determine serum total thyroxine levels. Only three additions are required, of standard or sample, labelled thyroxine and antibody in polyethylene glycol. After 2 hours' incubation at room temperature the antibody-bound and free fractions are separated by centrifugation. Serum total thyroxine levels were measured in 195 euthyroid subjects and it was established that normal values lay within the range 57 to 155 nmol/1. Serial blood samples taken over a 24-hour period, from 11 subjects, indicated that there was no circadian rhythm so that samples for total thyroxine assay can be taken at any time of the day. Similar results were obtained using serum or plasma. Satisfactory results were obtained for three quality control sera when measured by seven different laboratories using this method. PMID:932232

  9. Implementing self sustained quality control procedures in a clinical laboratory.

    PubMed

    Khatri, Roshan; K C, Sanjay; Shrestha, Prabodh; Sinha, J N

    2013-01-01

    Quality control is an essential component in every clinical laboratory which maintains the excellence of laboratory standards, supplementing to proper disease diagnosis, patient care and resulting in overall strengthening of health care system. Numerous quality control schemes are available, with combinations of procedures, most of which are tedious, time consuming and can be "too technical" whereas commercially available quality control materials can be expensive especially for laboratories in developing nations like Nepal. Here, we present a procedure performed at our centre with self prepared control serum and use of simple statistical tools for quality assurance. The pooled serum was prepared as per guidelines for preparation of stabilized liquid quality control serum from human sera. Internal Quality Assessment was performed on this sample, on a daily basis which included measurement of 12 routine biochemical parameters. The results were plotted on Levey-Jennings charts and analysed with quality control rules, for a period of one month. The mean levels of biochemical analytes in self prepared control serum were within normal physiological range. This serum was evaluated every day along with patients' samples. The results obtained were plotted on control charts and analysed using common quality control rules to identify possible systematic and random errors. Immediate mitigation measures were taken and the dispatch of erroneous reports was avoided. In this study we try to highlight on a simple internal quality control procedure which can be performed by laboratories, with minimum technology, expenditure, and expertise and improve reliability and validity of the test reports.

  10. A high-damping magnetorheological elastomer with bi-directional magnetic-control modulus for potential application in seismology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Miao, E-mail: yumiao@cqu.edu.cn; Qi, Song; Fu, Jie

    A high-damping magnetorheological elastomer (MRE) with bi-directional magnetic-control modulus is developed. This MRE was synthesized by filling NdFeB particles into polyurethane (PU)/ epoxy (EP) interpenetrating network (IPN) structure. The anisotropic samples were prepared in a permanent magnetic field and magnetized in an electromagnetic field of 1 T. Dynamic mechanical responses of the MRE to applied magnetic fields are investigated through magneto-rheometer, and morphology of MREs is observed via scanning electron microscope (SEM). Test result indicates that when the test field orientation is parallel to that of the sample's magnetization, the shear modulus of sample increases. On the other hand, when themore » orientation is opposite to that of the sample's magnetization, shear modulus decreases. In addition, this PU/EP IPN matrix based MRE has a high-damping property, with high loss factor and can be controlled by applying magnetic field. It is expected that the high damping property and the ability of bi-directional magnetic-control modulus of this MRE offer promising advantages in seismologic application.« less

  11. Feasibility of Xpert Ebola Assay in Médecins Sans Frontières Ebola Program, Guinea

    PubMed Central

    Chaillet, Pascale; Sow, Mamadou Saliou; Amand, Mathieu; van Vyve, Charlotte; Jonckheere, Sylvie; Crestani, Rosa; Sprecher, Armand; Van Herp, Michel; Chua, Arlene; Piriou, Erwan; Koivogui, Lamine; Antierens, Annick

    2016-01-01

    Rapid diagnostic methods are essential in control of Ebola outbreaks and lead to timely isolation of cases and improved epidemiologic surveillance. Diagnosis during Ebola outbreaks in West Africa has relied on PCR performed in laboratories outside this region. Because time between sampling and PCR results can be considerable, we assessed the feasibility and added value of using the Xpert Ebola Assay in an Ebola control program in Guinea. A total of 218 samples were collected during diagnosis, treatment, and convalescence of patients. Median time for obtaining results was reduced from 334 min to 165 min. Twenty-six samples were positive for Ebola virus. Xpert cycle thresholds were consistently lower, and 8 (31%) samples were negative by routine PCR. Several logistic and safety issues were identified. We suggest that implementation of the Xpert Ebola Assay under programmatic conditions is feasible and represents a major advance in diagnosis of Ebola virus disease without apparent loss of assay sensitivity. PMID:26812466

  12. Feasibility of Xpert Ebola Assay in Médecins Sans Frontières Ebola Program, Guinea.

    PubMed

    Van den Bergh, Rafael; Chaillet, Pascale; Sow, Mamadou Saliou; Amand, Mathieu; van Vyve, Charlotte; Jonckheere, Sylvie; Crestani, Rosa; Sprecher, Armand; Van Herp, Michel; Chua, Arlene; Piriou, Erwan; Koivogui, Lamine; Antierens, Annick

    2016-02-01

    Rapid diagnostic methods are essential in control of Ebola outbreaks and lead to timely isolation of cases and improved epidemiologic surveillance. Diagnosis during Ebola outbreaks in West Africa has relied on PCR performed in laboratories outside this region. Because time between sampling and PCR results can be considerable, we assessed the feasibility and added value of using the Xpert Ebola Assay in an Ebola control program in Guinea. A total of 218 samples were collected during diagnosis, treatment, and convalescence of patients. Median time for obtaining results was reduced from 334 min to 165 min. Twenty-six samples were positive for Ebola virus. Xpert cycle thresholds were consistently lower, and 8 (31%) samples were negative by routine PCR. Several logistic and safety issues were identified. We suggest that implementation of the Xpert Ebola Assay under programmatic conditions is feasible and represents a major advance in diagnosis of Ebola virus disease without apparent loss of assay sensitivity.

  13. Evaluation of a Dust Control for a Small Slab-Riding Dowel Drill for Concrete Pavement

    PubMed Central

    Echt, Alan; Mead, Kenneth

    2016-01-01

    Purpose To assess the effectiveness of local exhaust ventilation to control respirable crystalline silica exposures to acceptable levels during concrete dowel drilling. Approach Personal breathing zone samples for respirable dust and crystalline silica were collected while laborers drilled holes 3.5 cm diameter by 36 cm deep in a concrete slab using a single-drill slab-riding dowel drill equipped with local exhaust ventilation. Data were collected on air flow, weather, and productivity. Results All respirable dust samples were below the 90 µg detection limit which, when combined with the largest sample volume, resulted in a minimum detectable concentration of 0.31 mg m−3. This occurred in a 32-min sample collected when 27 holes were drilled. Quartz was only detected in one air sample; 0.09 mg m−3 of quartz was found on an 8-min sample collected during a drill maintenance task. The minimum detectable concentration for quartz in personal air samples collected while drilling was performed was 0.02 mg m−3. The average number of holes drilled during each drilling sample was 23. Over the course of the 2-day study, air flow measured at the dust collector decreased from 2.2 to 1.7 m3 s−1. Conclusions The dust control performed well under the conditions of this test. The initial duct velocity with a clean filter was sufficient to prevent settling, but gradually fell below the recommended value to prevent dust from settling in the duct. The practice of raising the drill between each hole may have prevented the dust from settling in the duct. A slightly higher flow rate and an improved duct design would prevent settling without regard to the position of the drill. PMID:26826033

  14. A Molecular Approach to Nested RT-PCR Using a New Set of Primers for the Detection of the Human Immunodeficiency Virus Protease Gene.

    PubMed

    Zarei, Mohammad; Ravanshad, Mehrdad; Bagban, Ashraf; Fallahi, Shahab

    2016-07-01

    The human immunodeficiency virus (HIV-1) is the etiologic agent of AIDS. The disease can be transmitted via blood in the window period prior to the development of antibodies to the disease. Thus, an appropriate method for the detection of HIV-1 during this window period is very important. This descriptive study proposes a sensitive, efficient, inexpensive, and easy method to detect HIV-1. In this study 25 serum samples of patients under treatment and also 10 positive and 10 negative control samples were studied. Twenty-five blood samples were obtained from HIV-1-infected individuals who were receiving treatment at the acquired immune deficiency syndrome (AIDS) research center of Imam Khomeini hospital in Tehran. The identification of HIV-1-positive samples was done by using reverse transcription to produce copy deoxyribonucleic acid (cDNA) and then optimizing the nested polymerase chain reaction (PCR) method. Two pairs of primers were then designed specifically for the protease gene fragment of the nested real time-PCR (RT-PCR) samples. Electrophoresis was used to examine the PCR products. The results were analyzed using statistical tests, including Fisher's exact test, and SPSS17 software. The 325 bp band of the protease gene was observed in all the positive control samples and in none of the negative control samples. The proposed method correctly identified HIV-1 in 23 of the 25 samples. These results suggest that, in comparison with viral cultures, antibody detection by enzyme linked immunosorbent assay (ELISAs), and conventional PCR methods, the proposed method has high sensitivity and specificity for the detection of HIV-1.

  15. Six-month trial of bupropion with contingency management for cocaine dependence in a methadone-maintained population.

    PubMed

    Poling, James; Oliveto, Alison; Petry, Nancy; Sofuoglu, Mehmet; Gonsai, Kishorchandra; Gonzalez, Gerardo; Martell, Bridget; Kosten, Thomas R

    2006-02-01

    No effective pharmacotherapies exist for cocaine dependence, although contingency management (CM) has demonstrated efficacy. To compare the efficacy of bupropion hydrochloride and CM for reducing cocaine use in methadone hydrochloride-maintained individuals. This 25-week, placebo-controlled, double-blind trial randomly assigned participants to 1 of 4 treatment conditions: CM and placebo (CMP), CM and 300 mg/d of bupropion hydrochloride (CMB), voucher control and placebo (VCP), or voucher control and bupropion (VCB). Outpatient clinic at the Veterans Affairs Connecticut Healthcare System. A total of 106 opiate-dependent, cocaine-abusing individuals. All study participants received methadone hydrochloride (range, 60-120 mg). Participants receiving bupropion hydrochloride were given 300 mg/d beginning at week 3. In the CM conditions, each urine sample negative for both opioids and cocaine resulted in a monetary-based voucher that increased for consecutively drug-free urine samples during weeks 1 to 13. Completion of abstinence-related activities also resulted in a voucher. During weeks 14 to 25, only completion of activities was reinforced in the CM group, regardless of sample results. The voucher control groups received vouchers for submitting urine samples, regardless of results, throughout the study. Thrice-weekly urine toxicologic test results for cocaine and heroin. Groups did not differ in baseline characteristics or retention rates. Opiate use decreased significantly, with all treatment groups attaining equivalent amounts of opiate use at the end of the study. In the CMB group, the proportion of cocaine-positive samples significantly decreased during weeks 3 to 13 (P<.001) relative to week 3 and remained low during weeks 14 to 25. In the CMP group, cocaine use significantly increased during weeks 3 to 13 (P<.001) relative to week 3, but then cocaine use significantly decreased relative to the initial slope during weeks 14 to 25 (P<.001). In contrast, by treatment end, the VCB and VCP groups showed no significant improvement in cocaine use. These findings suggest that combining CM with bupropion for the treatment of cocaine addiction may significantly improve outcomes relative to bupropion alone.

  16. Effects of a Worksite Tobacco Control Intervention in India: The Mumbai Worksite Tobacco Control Study, a Cluster Randomized Trial

    PubMed Central

    Sorensen, Glorian; Pednekar, Mangesh; Cordeira, Laura Shulman; Pawar, Pratibha; Nagler, Eve; Stoddard, Anne M.; Kim, Hae-Young; Gupta, Prakash C.

    2016-01-01

    Objectives We assessed a worksite intervention designed to promote tobacco control among manufacturing workers in Greater Mumbai, India. Methods We used a cluster-randomized design to test an integrated health promotion/health protection intervention, which addressed changes at the management and worker levels. Between July 2012 and July 2013, we recruited 20 worksites on a rolling basis and randomly assigned them to intervention or delayed-intervention control conditions. The follow-up survey was conducted between December 2013 and November 2014. Results The difference in 30-day quit rates between intervention and control conditions was statistically significant for production workers (OR=2.25, P=0.03), although not for the overall sample (OR=1.70; P=0.12). The intervention resulted in a doubling of the 6-month cessation rates among workers in the intervention worksites compared to those in the control, for production workers (OR=2.29; P=0.07) and for the overall sample (OR=1.81; P=0.13), but the difference did not reach statistical significance. Conclusions These findings demonstrate the potential impact of a tobacco control intervention that combined tobacco control and health protection programming within Indian manufacturing worksites. PMID:26883793

  17. The Relationship of Pupil Control Ideology to Students' Rights Attitudes.

    ERIC Educational Resources Information Center

    Jones, Lynn

    As a result of increased court intervention in favor of students' rights, a review of a sample of teachers concerning their attitudes about student control was examined. Taking into consideration the teachers' attitudes concerning student rights, the Pupil Control Ideology test and the Students' Rights Acceptance Scale were used as measurement…

  18. [Epidemiological surveillance of cystic echinococcosis in dogs, sheep farms and humans in the Rio Negro Province].

    PubMed

    Pérez, Alicia; Costa, María T; Cantoni, Gustavo; Mancini, Sergio; Mercapide, Carlos; Herrero, Eduardo; Volpe, Marcela; Araya, Daniel; Talmon, Gabriel; Chiosso, Carlos; Vázquez, Gabriela; Del Carpio, Mario; Santillan, Graciela; Larrieu, Edmundo

    2006-01-01

    The surveillance of infection for Echinococcus granulosus in the Province of Rio Negro during 1980-2002 included serological and ultrasonographic screening in humans and arecoline test in dogs. In lieu of the limitations of the arecoline test the proposal was to supplant that test for the copro ELISA-copro/Western Blot complex applied to feces collected from the environment. The objective was to compare the pros and cons of the two tests and to evaluate the human and the canine infection prevalence. The working area encompassed 7 Departments with systematic canine parasiticide activities (Program Area) and 4 Departments, not endemic, as Control Area. The arecoline test was applied to the dogs in assembled groups with the voluntary participation of their owners (not randomized sampling). Samples for the detection of coproantigens were obtained from sheep farms selected at random and analyzed by the complex copro-ELISA /Western Blot. Prevalence in man was determined by screening the school population (6 to 14 years old) by ultrasound, and by means of the compulsory notification of cases from the official system. Dogs (416) were tested with arecoline, 365 of which belonged to the Program Area. Of these 19 (5.2%) resulted positive, while none of 51 dogs from the Control Area were positive. Samples (748) of feces were tested to detect coproantigens, obtaining 37 positive samples within the Program Area and 4 within the Control Area. Farms (271) from the livestock estate unit were evaluated, out of which 236 belonged to the Program Area, gave 32 (13.6%) positive results, while 4 (11.4%) of 35 from the Control Area resulted positive. Sonography tests (7421) were done in the Program Area detecting 40 (0.5%) carriers, while in the Control Area, over 1732 tests, 9 (0.5%) resulted positive. The arecoline test provides information about the dog prevalence while the detection of coproantigens in feces collected from the environment allowed to enhance the quality of the information, and the identification of environments where specific control activities focusing on risk must be concentrated. Also the study allowed to recognize new transmission areas.

  19. Delayed matching to sample and concurrent learning in nonamnesic humans with alcohol dependence.

    PubMed

    Bowden, S C; Benedikt, R; Ritter, A J

    1992-05-01

    Small samples of alcohol-dependent subjects who showed no clinical signs of Wernicke-Korsakoff syndrome were compared with nonalcohol-dependent controls on two animal memory tests which are performed poorly by human amnesics. Compared to the control subjects, the alcohol-dependent subjects' performance was impaired on a version of the delayed matching to sample task. On concurrent discrimination learning the overall group difference just failed to reach significance. The results are interpreted as suggesting that behavioural impairment may occur in alcohol-dependent subjects who are not clinically amnesic, and that the impairment is similar in type to that observed in cases of severe Wernicke-Korsakoff syndrome.

  20. Stationary microfluidics: molecular diagnostic assays by moving magnetic beads through non-moving liquids

    NASA Astrophysics Data System (ADS)

    Becker, Holger; Carstens, Cornelia; Kuhlmeier, Dirk; Sandetskaya, Natalia; Schröter, Nicole; Zilch, Christian; Gärtner, Claudia

    2013-03-01

    Commonly, microfluidic devices are based on the movement of fluids. For molecular diagnostics assays which often include steps like PCR, this practically always involves a more or less complicated set of external pumps, valves and liquid controls. In the presented paper, we follow a different approach in which the fluid after sample introduction remains stationary and the main bioactive sample molecules are moved through a chain of reaction compartments which contain the different reagents necessary for the assay. The big advantage of this concept is the lack of any external fluid actuation/control. Results on sample carry-over experiments and complete assays will be given.

  1. A versatile system for biological and soil chemical tests on a planetary landing craft. II - Hardware development

    NASA Technical Reports Server (NTRS)

    Martin, J. P.; Kok, B.; Radmer, R.

    1976-01-01

    A system has been under development which is designed to seek remotely for clues to life in planetary soil samples. The basic approach is a set of experiments, all having a common sensor, a gas analysis mass spectrometer which monitors gas composition in the head spaces above sealed, temperature controlled soil samples. Versatility is obtained with up to three preloaded, sealed fluid injector capsules for each of eleven soil test cells. Tests results with an engineering model has demonstrated performance capability of subsystem components such as soil distribution, gas sampling valves, injector mechanisms, temperature control, and test cell seal.

  2. Cognitive emotion regulation strategies in patients with functional dyspepsia and healthy controls - A comparative study

    PubMed Central

    Mazaheri, Mina; Afshar, Hamid; Nikneshan, Shekoufeh; Adibi, Peyman

    2016-01-01

    Background: Patients with functional dyspepsia (FD) may use specific coping strategies. Hence, the aim of the present study was to compare cognitive emotion regulation strategies in FD patients and healthy controls. Materials and Methods: This was a descriptive observational study. The sample consisted of 86 individuals, 43 of whom were patients diagnosed with FD. The patients referred to the psychosomatic disorders clinic, Isfahan, Iran. The comparative sample included 43 healthy controls (without digestive diagnoses) matched with the patients by age and gender. Subjects completed data on demographic factors and cognitive emotion regulation questionnaire. Results: The results indicated that there are significant differences between patients with FD and healthy controls according to using cognitive strategies. Scores of healthy controls in positive reappraisal and acceptance were significantly more than FD patients, and inversely, scores of FD patients in rumination and other-blame were meaningfully more than healthy controls. Conclusion: FD patients apply less adaptive strategies and more maladaptive strategies. It is seemed psychological interventions that focus on reducing maladaptive strategies and increasing adaptive strategies could be effective for FD patients. PMID:28217634

  3. The Relationship Between Trait Procrastination, Internet Use, and Psychological Functioning: Results From a Community Sample of German Adolescents.

    PubMed

    Reinecke, Leonard; Meier, Adrian; Beutel, Manfred E; Schemer, Christian; Stark, Birgit; Wölfling, Klaus; Müller, Kai W

    2018-01-01

    Adolescents with a strong tendency for irrational task delay (i.e., high trait procrastination) may be particularly prone to use Internet applications simultaneously to other tasks (e.g., during homework) and in an insufficiently controlled fashion. Both Internet multitasking and insufficiently controlled Internet usage may thus amplify the negative mental health implications that have frequently been associated with trait procrastination. The present study explored this role of Internet multitasking and insufficiently controlled Internet use for the relationship between trait procrastination and impaired psychological functioning in a community sample of N = 818 early and middle adolescents. Results from multiple regression analyses indicate that trait procrastination was positively related to Internet multitasking and insufficiently controlled Internet use. Insufficiently controlled Internet use, but not Internet multitasking, was found to partially statistically mediate the association between trait procrastination and adolescents' psychological functioning (i.e., stress, sleep quality, and relationship satisfaction with parents). The study underlines that adolescents with high levels of trait procrastination may have an increased risk for negative outcomes of insufficiently controlled Internet use.

  4. The Relationship Between Trait Procrastination, Internet Use, and Psychological Functioning: Results From a Community Sample of German Adolescents

    PubMed Central

    Reinecke, Leonard; Meier, Adrian; Beutel, Manfred E.; Schemer, Christian; Stark, Birgit; Wölfling, Klaus; Müller, Kai W.

    2018-01-01

    Adolescents with a strong tendency for irrational task delay (i.e., high trait procrastination) may be particularly prone to use Internet applications simultaneously to other tasks (e.g., during homework) and in an insufficiently controlled fashion. Both Internet multitasking and insufficiently controlled Internet usage may thus amplify the negative mental health implications that have frequently been associated with trait procrastination. The present study explored this role of Internet multitasking and insufficiently controlled Internet use for the relationship between trait procrastination and impaired psychological functioning in a community sample of N = 818 early and middle adolescents. Results from multiple regression analyses indicate that trait procrastination was positively related to Internet multitasking and insufficiently controlled Internet use. Insufficiently controlled Internet use, but not Internet multitasking, was found to partially statistically mediate the association between trait procrastination and adolescents’ psychological functioning (i.e., stress, sleep quality, and relationship satisfaction with parents). The study underlines that adolescents with high levels of trait procrastination may have an increased risk for negative outcomes of insufficiently controlled Internet use. PMID:29942268

  5. Method matters: Experimental evidence for shorter avian sperm in faecal compared to abdominal massage samples

    PubMed Central

    Cockburn, Glenn; Sánchez-Tójar, Alfredo; Løvlie, Hanne; Schroeder, Julia

    2017-01-01

    Birds are model organisms in sperm biology. Previous work in zebra finches, suggested that sperm sampled from males' faeces and ejaculates do not differ in size. Here, we tested this assumption in a captive population of house sparrows, Passer domesticus. We compared sperm length in samples from three collection techniques: female dummy, faecal and abdominal massage samples. We found that sperm were significantly shorter in faecal than abdominal massage samples, which was explained by shorter heads and midpieces, but not flagella. This result might indicate that faecal sampled sperm could be less mature than sperm collected by abdominal massage. The female dummy method resulted in an insufficient number of experimental ejaculates because most males ignored it. In light of these results, we recommend using abdominal massage as a preferred method for avian sperm sampling. Where avian sperm cannot be collected by abdominal massage alone, we advise controlling for sperm sampling protocol statistically. PMID:28813481

  6. Verification of out-of-control situations detected by "average of normal" approach.

    PubMed

    Liu, Jiakai; Tan, Chin Hon; Loh, Tze Ping; Badrick, Tony

    2016-11-01

    "Average of normal" (AoN) or "moving average" is increasingly used as an adjunct quality control tool in laboratory practice. Little guidance exists on how to verify if an out-of-control situation in the AoN chart is due to a shift in analytical performance, or underlying patient characteristics. Through simulation based on clinical data, we examined 1) the location of the last apparently stable period in the AoN control chart after an analytical shift, and 2) an approach to verify if the observed shift is related to an analytical shift by repeat testing of archived patient samples from the stable period for 21 common analytes. The number of blocks of results to look back for the stable period increased with the duration of the analytical shift, and was larger when smaller AoN block sizes were used. To verify an analytical shift, 3 archived samples from the analytically stable period should be retested. In particular, the process is deemed to have shifted if a difference of >2 analytical standard deviations (i.e. 1:2s rejection rule) between the original and retested results are observed in any of the 3 samples produced. The probability of Type-1 error (i.e., false rejection) and power (i.e., detecting true analytical shift) of this rule are <0.1 and >0.9, respectively. The use of appropriately archived patient samples to verify an apparent analytical shift is preferred to quality control materials. Nonetheless, the above findings may also apply to quality control materials, barring matrix effects. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  7. Passive Baited Sequential Fly Trap

    USDA-ARS?s Scientific Manuscript database

    Sampling fly populations associated with human populations is needed to understand diel behavior and to monitor population densities before and after control operations. Population control measures are dependent on the results of monitoring efforts as they may provide insight into the fly behavior ...

  8. Disturbed expression of type 1 iodothyronine deiodinase splice variants in human renal cancer.

    PubMed

    Piekielko-Witkowska, Agnieszka; Master, Adam; Wojcicka, Anna; Boguslawska, Joanna; Brozda, Izabela; Tanski, Zbigniew; Nauman, Alicja

    2009-10-01

    Alternative splicing, one of the sources of protein diversity, is often disturbed in cancer. Type 1 iodothyronine deiodinase (DIO1) catalyzes deiodination of thyroxine generating triiodothyronine, an important regulator of cell proliferation and differentiation. The expression of DIO1 is disturbed in different types of cancer. The aim of the study was to analyze the alternative splicing of DIO1 and its possible disturbance in renal cancer. Using real-time PCR, we analyzed 19 tissue samples (T) of renal cancer and 19 matched control samples (C) of the opposite pole of the kidney, not infiltrated by tumor, and 6 control samples (N) (nonneoplastic kidney abnormalities). Cloning of DIO1 mRNA isoforms revealed 11 different transcripts, among them 7 new splice variants, not previously reported. The expression of all variants of DIO1 was dramatically (>90%) and significantly (p < or = 0.0003) lowered in samples T compared to control samples C. The ratio of mRNA isoforms encoding DIO1 protein variants possessing or lacking the active center was lowered in samples T compared with control samples C, suggesting disturbed alternative splicing of DIO1. The expression of mRNA of splicing factors SF2/ASF (splicing factor-2/alternative-splicing factor) and hnRNPA1 (heterogeneous ribonucleoprotein A1), regulating 5'-splice site selection, was significantly but not proportionally lowered in samples T compared to samples C. The mRNA ratio of splicing factors SF2/ASF and hnRNPA1 correlated with the ratio of mRNA isoforms encoding DIO1 protein variants possessing or lacking the active center in controls C but not in samples T. Our results show that the expression and alternative splicing of DIO1 mRNA is disturbed in renal cancer, possibly due to changes in expression of splicing factors SF2/ASF and hnRNPA1.

  9. Time Course of Brain Network Reconfiguration Supporting Inhibitory Control.

    PubMed

    Popov, Tzvetan; Westner, Britta U; Silton, Rebecca L; Sass, Sarah M; Spielberg, Jeffrey M; Rockstroh, Brigitte; Heller, Wendy; Miller, Gregory A

    2018-05-02

    Hemodynamic research has recently clarified key nodes and links in brain networks implementing inhibitory control. Although fMRI methods are optimized for identifying the structure of brain networks, the relatively slow temporal course of fMRI limits the ability to characterize network operation. The latter is crucial for developing a mechanistic understanding of how brain networks shift dynamically to support inhibitory control. To address this critical gap, we applied spectrally resolved Granger causality (GC) and random forest machine learning tools to human EEG data in two large samples of adults (test sample n = 96, replication sample n = 237, total N = 333, both sexes) who performed a color-word Stroop task. Time-frequency analysis confirmed that recruitment of inhibitory control accompanied by slower behavioral responses was related to changes in theta and alpha/beta power. GC analyses revealed directionally asymmetric exchanges within frontal and between frontal and parietal brain areas: top-down influence of superior frontal gyrus (SFG) over both dorsal ACC (dACC) and inferior frontal gyrus (IFG), dACC control over middle frontal gyrus (MFG), and frontal-parietal exchanges (IFG, precuneus, MFG). Predictive analytics confirmed a combination of behavioral and brain-derived variables as the best set of predictors of inhibitory control demands, with SFG theta bearing higher classification importance than dACC theta and posterior beta tracking the onset of behavioral response. The present results provide mechanistic insight into the biological implementation of a psychological phenomenon: inhibitory control is implemented by dynamic routing processes during which the target response is upregulated via theta-mediated effective connectivity within key PFC nodes and via beta-mediated motor preparation. SIGNIFICANCE STATEMENT Hemodynamic neuroimaging research has recently clarified regional structures in brain networks supporting inhibitory control. However, due to inherent methodological constraints, much of this research has been unable to characterize the temporal dynamics of such networks (e.g., direction of information flow between nodes). Guided by fMRI research identifying the structure of brain networks supporting inhibitory control, results of EEG source analysis in a test sample ( n = 96) and replication sample ( n = 237) using effective connectivity and predictive analytics strategies advance a model of inhibitory control by characterizing the precise temporal dynamics by which this network operates and exemplify an approach by which mechanistic models can be developed for other key psychological processes. Copyright © 2018 the authors 0270-6474/18/384348-09$15.00/0.

  10. Microbial ecology laboratory procedures manual NASA/MSFC

    NASA Technical Reports Server (NTRS)

    Huff, Timothy L.

    1990-01-01

    An essential part of the efficient operation of any microbiology laboratory involved in sample analysis is a standard procedures manual. The purpose of this manual is to provide concise and well defined instructions on routine technical procedures involving sample analysis and methods for monitoring and maintaining quality control within the laboratory. Of equal importance is the safe operation of the laboratory. This manual outlines detailed procedures to be followed in the microbial ecology laboratory to assure safety, analytical control, and validity of results.

  11. Social cognition in schizophrenia: Factor structure, clinical and functional correlates

    PubMed Central

    Buck, Benjamin E.; Healey, Kristin M.; Gagen, Emily C.; Roberts, David L.; Penn, David L.

    2016-01-01

    Background Social cognition is consistently impaired in people with schizophrenia, separable from general neurocognition, predictive of real-world functioning, and amenable to psychosocial treatment. Few studies have empirically examined its underlying factor structure. Aims The present study (1) examines the factor structure of social cognition in both a sample of individuals with schizophrenia-spectrum disorders and non-clinical controls, and (2) explores relationships of factors to neurocognition, symptoms and functioning. Method A factor analysis was conducted on social cognition measures in a sample of sixty-five individuals with schizophrenia or schizoaffective disorder, and fifty control participants. The resulting factors were examined for their relationships to symptoms and functioning. Results Results suggested a two-factor structure in the schizophrenia sample (social cognition skill and hostile attributional style) and a three-factor structure in the non-clinical sample (hostile attributional style, higher-level inferential processing, and lower-level cue detection). In the schizophrenia sample, the social cognition skill factor was significantly related to negative symptoms and social functioning, while hostile attributional style predicted positive and general psychopathology symptoms. Conclusions The factor structure of social cognition in schizophrenia separates hostile attributional style and social cognition skill, and each show differential relationships to relevant clinical variables in schizophrenia. PMID:26747063

  12. Artificial receptors in serologic tests for the early diagnosis of dengue virus infection.

    PubMed

    Tai, Dar-Fu; Lin, Chung-Yin; Wu, Tzong-Zeng; Huang, Jyh-Hsiung; Shu, Pei-Yun

    2006-08-01

    Because of the range and nonspecificity of clinical presentations of dengue virus infections, we felt there was a need to create diagnostic tests. We used artificial receptors for the virus to develop serologic assays to detect dengue virus infection. We coated a quartz crystal microbalance (QCM) with molecularly imprinted polymers specific for nonstructural protein 1 of flavivirus. These artificial receptors were specifically created on a QCM chip by polymerization of monomers and were cross-linked in the presence of the epitope site of nonstructural protein 1. We tested serum samples from patients with confirmed cases of dengue reported to the Center for Disease Control in Taipei. Samples were diluted 100-fold; no other sample pretreatment was used. The QCM response was compared with results of monoclonal ELISA. QCM signals were >15 Hz in 18 of 21 (86%) of dengue samples and in 0 of 16 control samples. The correlation (r2) of the QCM response and the ELISA result was 0.73. Within-run and run-to-run imprecisions (CV) were 4%-28% and 10%-32%, respectively. The described assay offers a serologic technique for diagnosis of early viremia. The results illustrate the potential of well-organized polymers on the highly sensitive sensor system for diagnostic and biotechnological applications.

  13. Neonicotinoid concentrations in urine from chronic kidney disease patients in the North Central Region of Sri Lanka.

    PubMed

    Kabata, Risako; Nanayakkara, Shanika; Senevirathna, Stmld; Harada, Kouji H; Chandrajith, Rohana; Hitomi, Toshiaki; Abeysekera, Tilak; Takasuga, Takumi; Koizumi, Akio

    2016-01-01

    Neonicotinoid insecticides have been widely used around the world since the 1990s. Reports have been made since the 1990s of rice paddy farmers in the North Central Region (NCR) of Sri Lanka suffering from chronic kidney disease with unknown etiology (CKDu). A preliminary evaluation of the exposure of local farmers in the NCR of Sri Lanka to neonicotinoids was performed. We analyzed neonicotinoid and neonicotinoid metabolite concentrations in spot urine samples. We selected 40 samples, 10 from farmers with CKDu and 10 from controls from each of two areas, Medawachchiya and Girandurukotte. Imidacloprid and desmethyl-acetamiprid were found at significantly higher concentrations in the control samples (with medians of 51 ng/l and 340 ng/l, respectively) than in the CKDu samples (medians of 15 ng/l and 150 ng/l, respectively) when the results were not adjusted for the creatinine contents. None of the six compounds that were measured in the urine samples were found at significantly higher concentrations in the CKDu samples than in the control samples. None of the neonicotinoid concentrations in the samples analyzed in this study exceeded the concentrations that have been found in samples from the general population of Japan. Farmers (both with and without CKDu) living in CKDu-endemic areas in the NCR of Sri Lanka are exposed to lower neonicotinoid concentrations than non-occupationally exposed residents of Japan.

  14. On the continuous dependence with respect to sampling of the linear quadratic regulator problem for distributed parameter systems

    NASA Technical Reports Server (NTRS)

    Rosen, I. G.; Wang, C.

    1990-01-01

    The convergence of solutions to the discrete or sampled time linear quadratic regulator problem and associated Riccati equation for infinite dimensional systems to the solutions to the corresponding continuous time problem and equation, as the length of the sampling interval (the sampling rate) tends toward zero (infinity) is established. Both the finite and infinite time horizon problems are studied. In the finite time horizon case, strong continuity of the operators which define the control system and performance index together with a stability and consistency condition on the sampling scheme are required. For the infinite time horizon problem, in addition, the sampled systems must be stabilizable and detectable, uniformly with respect to the sampling rate. Classes of systems for which this condition can be verified are discussed. Results of numerical studies involving the control of a heat/diffusion equation, a hereditary of delay system, and a flexible beam are presented and discussed.

  15. On the continuous dependence with respect to sampling of the linear quadratic regulator problem for distributed parameter system

    NASA Technical Reports Server (NTRS)

    Rosen, I. G.; Wang, C.

    1992-01-01

    The convergence of solutions to the discrete- or sampled-time linear quadratic regulator problem and associated Riccati equation for infinite-dimensional systems to the solutions to the corresponding continuous time problem and equation, as the length of the sampling interval (the sampling rate) tends toward zero(infinity) is established. Both the finite-and infinite-time horizon problems are studied. In the finite-time horizon case, strong continuity of the operators that define the control system and performance index, together with a stability and consistency condition on the sampling scheme are required. For the infinite-time horizon problem, in addition, the sampled systems must be stabilizable and detectable, uniformly with respect to the sampling rate. Classes of systems for which this condition can be verified are discussed. Results of numerical studies involving the control of a heat/diffusion equation, a hereditary or delay system, and a flexible beam are presented and discussed.

  16. The first 62 AGNs observed with SDSS-IV MaNGA - I. Their characterization and definition of a control sample

    NASA Astrophysics Data System (ADS)

    Rembold, Sandro B.; Shimoia, Jáderson S.; Storchi-Bergmann, Thaisa; Riffel, Rogério; Riffel, Rogemar A.; Mallmann, Nícolas D.; do Nascimento, Janaína C.; Moreira, Thales N.; Ilha, Gabriele S.; Machado, Alice D.; Cirolini, Rafael; da Costa, Luiz N.; Maia, Marcio A. G.; Santiago, Basílio X.; Schneider, Donald P.; Wylezalek, Dominika; Bizyaev, Dmitry; Pan, Kaike; Müller-Sánchez, Francisco

    2017-12-01

    We report the characterization of the first 62 Mapping Nearby Galaxies at the Apache Point Observatory active galactic nuclei (AGNs) hosts and the definition of a control sample of non-active galaxies. This control sample was selected in order to match the AGN hosts in terms of stellar mass, redshift, visual morphology and inclination. The stellar masses are in the range 9.4

  17. Dieting and the self-control of eating in everyday environments: An experience sampling study

    PubMed Central

    Hofmann, Wilhelm; Adriaanse, Marieke; Vohs, Kathleen D.; Baumeister, Roy F.

    2013-01-01

    Objective The literature on dieting has sparked several debates over how restrained eaters differ from unrestrained eaters in their self-regulation of healthy and unhealthy food desires and what distinguishes successful from unsuccessful dieters. We addressed these debates using a four-component model of self-control that was tested using ecological momentary assessment, long-term weight change, and a laboratory measure of inhibitory control. Design A large sample of adults varying in dietary restraint and inhibitory control (as measured by a Stroop task) were equipped with smartphones for a week. They were beeped on random occasions and provided information on their experience and control of healthy and unhealthy food desires in everyday environments. Main Outcome Measures Desire strength, experienced conflict, resistance, enactment of desire, and weight change after a four-month follow-up. Results and Conclusions Dietary restraint was unrelated to desire frequency and strength, but associated with higher conflict experiences and motivation to use self-control with regard to food desires. Most importantly, relationships between and among dietary restraint and resistance, enactment of desire, and long-term weight change were moderated by inhibitory control: Compared to dieters low in response inhibition, dieters high in response inhibition were more likely to attempt to resist food desires, not consume desired food (especially unhealthy food), and objectively lost more weight over the ensuing four months. These results highlight the combinatory effects of aspects of the self-control process in dieters and highlight the value in linking theoretical process frameworks, experience sampling, and laboratory-based assessment in health science. PMID:23751109

  18. The Child Dental Control Assessment (CDCA) in youth: reliability, validity and cross-cultural differences.

    PubMed

    Coolidge, T; Heima, M; Heaton, L J; Nakai, Y; Höskuldsson, O; Smith, T A; Weinstein, P; Milgrom, P

    2005-03-01

    The Child Dental Control Assessment (CDCA) measures children's preferred control strategies in the dental situation. Three studies are reported, assessing aspects of this instrument in youths from the USA, Japan and Australia. In particular, measurements were made as to the reliability and validity of this instrument in this age group in the three cultures, as well as comparing some results across cultures. These studies used a questionnaire design. Questionnaires (including the CDCA and other measures) were given to youths aged 11-15 in the three cultures. In one culture, youths received the questionnaire twice, to compute test-retest reliability. The measure's reliability and validity were similar to those of other measures. The CDCA behaves similarly to the Revised Iowa Dental Control Index (R-IDCI). Youths in all three cultures showed similar responses, although the Japanese were less likely to endorse items. Internal reliability of the scale ranged from 0.74 to 0.85. Test- retest reliability was 0.74. Participants in the High Desire/Low Predicted classification on the R-IDCI scored higher on the CDCA (t (73) = 2.9, p < .01). In the Japanese and Australian samples the correlation between CDCA and dental fear was 0.29-0.33 (p < .001). The Australian and USA samples scored significantly higher than the Japanese sample (overall F(2,1544) = 383.98, p < .001, followed by Tukey's HSD, p < .001). These results provide evidence for the reliability and validity of the CDCA in youth. It appears to measure the discrepancy between Desired and Predicted Control identified in the Revised Iowa Dental Control Index (R-IDCI). Responses of the youth in all three cultures were similar, indicating common dental control preferences for individuals of this age. However, consistent with cultural values, Japanese youth were less likely to endorse the control strategies. These results underline the need to develop culturally-specific, as well as situationally-specific control measures.

  19. Depletion of Stercobilin in Fecal Matter from a Mouse Model of Autism Spectrum Disorders

    PubMed Central

    Sekera, Emily R.; Rudolph, Heather L.; Carro, Stephen D.; Morales, Michael J.; Bett, Glenna C. L.; Rasmusson, Randall L.; Wood, Troy D.

    2017-01-01

    Introduction Autism spectrum disorders (ASD) are a group of neurodevelopmental disorders lacking a clinical biomarker for diagnosis. Emerging evidence shows that intestinal microflora from ASD subjects can be distinguished from controls, suggesting metabolite differences due to the action of intestinal microbes may provide a means for identifying potential biomarkers for ASD. Objectives The aim of this study was to determine if quantitative differences in levels of stercobilin and stercobilinogen, metabolites produced by biological action of intestinal microflora, exist in the fecal matter between an ASD mouse model population and controls. Methods Pairs of fecal samples were collected from two mouse groups, an ASD model group with Timothy syndrome 2 (TS2-NEO) and a gender-matched control group. After centrifugation, supernatant was spiked with an 18O-labeled stercobilin isotopomer and subjected to solid phase extraction for processing. Extracted samples were spotted on a stainless steel plate and subjected to matrix-assisted laser desorption and ionization mass spectrometry using dihydroxybenzoic acid as the matrix (n = 5). Peak areas for bilins and 18O-stercobilin isotopomers were determined in each fecal sample. Results A 40–45% depletion in stercobilin in TS2-NEO fecal samples compared with controls was observed with p < 0.05; a less dramatic depletion was observed for stercobilinogen. Conclusions The results show that stercobilin depletion in feces is observed for an ASD mouse model vs. controls. This may help to explain recent observations of a less diverse microbiome in humans with ASD and may prove helpful in developing a clinical ASD biomarker. PMID:29147105

  20. Influence of ultrasound pretreatment on wood physiochemical structure.

    PubMed

    He, Zhengbin; Wang, Zhenyu; Zhao, Zijian; Yi, Songlin; Mu, Jun; Wang, Xiaoxu

    2017-01-01

    As an initial step to increase the use of renewable biomass resources, this study was aimed at investigating the effects of ultrasound pretreatment on structural changes of wood. Samples were pretreated by ultrasound with the power of 300W and frequency of 28kHz in aqueous soda solution, aqueous acetic acid, or distilled water, then pretreated and control samples were characterized via X-ray diffraction (XRD), scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), and thermogravimetric analysis (TGA). The results shown that ultrasound pretreatment is indeed effective in modifying the physiochemical structure of eucalyptus wood; the pretreatment decreased the quantity of alkali metals (e.g., potassium, calcium and magnesium) in the resulting material. Compared to the control group, the residual char content of samples pretreated in aqueous soda solution increased by 10.08%-20.12% and the reaction temperature decreased from 361°C to 341°C, however, in samples pretreated by ultrasound in acetic solution or distilled water, the residual char content decreased by 12.40%-21.45% and there were no significant differences in reactivity apart from a slightly higher maximum reaction rate. Ultrasound pretreatment increased the samples' crystallinity up to 35.5% and successfully removed cellulose, hemicellulose, and lignin from the samples; the pretreatment also increased the exposure of the sample to the treatment solutions, broke down sample pits, and generated collapses and microchannels on sample pits, and removed attachments in the samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Sampled-data-based consensus and containment control of multiple harmonic oscillators: A motion-planning approach

    NASA Astrophysics Data System (ADS)

    Liu, Yongfang; Zhao, Yu; Chen, Guanrong

    2016-11-01

    This paper studies the distributed consensus and containment problems for a group of harmonic oscillators with a directed communication topology. First, for consensus without a leader, a class of distributed consensus protocols is designed by using motion planning and Pontryagin's principle. The proposed protocol only requires relative information measurements at the sampling instants, without requiring information exchange over the sampled interval. By using stability theory and the properties of stochastic matrices, it is proved that the distributed consensus problem can be solved in the motion planning framework. Second, for the case with multiple leaders, a class of distributed containment protocols is developed for followers such that their positions and velocities can ultimately converge to the convex hull formed by those of the leaders. Compared with the existing consensus algorithms, a remarkable advantage of the proposed sampled-data-based protocols is that the sampling periods, communication topologies and control gains are all decoupled and can be separately designed, which relaxes many restrictions in controllers design. Finally, some numerical examples are given to illustrate the effectiveness of the analytical results.

  2. Heating and thermal control of brazing technique to break contamination path for potential Mars sample return

    NASA Astrophysics Data System (ADS)

    Bao, Xiaoqi; Badescu, Mircea; Sherrit, Stewart; Bar-Cohen, Yoseph; Campos, Sergio

    2017-04-01

    The potential return of Mars sample material is of great interest to the planetary science community, as it would enable extensive analysis of samples with highly sensitive laboratory instruments. It is important to make sure such a mission concept would not bring any living microbes, which may possibly exist on Mars, back to Earth's environment. In order to ensure the isolation of Mars microbes from Earth's Atmosphere, a brazing sealing and sterilizing technique was proposed to break the Mars-to-Earth contamination path. Effectively, heating the brazing zone in high vacuum space and controlling the sample temperature for integrity are key challenges to the implementation of this technique. The break-thechain procedures for container configurations, which are being considered, were simulated by multi-physics finite element models. Different heating methods including induction and resistive/radiation were evaluated. The temperature profiles of Martian samples in a proposed container structure were predicted. The results show that the sealing and sterilizing process can be controlled such that the samples temperature is maintained below the level that may cause damage, and that the brazing technique is a feasible approach to breaking the contamination path.

  3. Ring trial among National Reference Laboratories for parasites to detect Trichinella spiralis larvae in pork samples according to the EU directive 2075/2005.

    PubMed

    Marucci, Gianluca; Pezzotti, Patrizio; Pozio, Edoardo

    2009-02-23

    To control Trichinella spp. infection in the European Union, all slaughtered pigs should be tested by one of the approved digestion methods described in EU directive 2075/2005. The aim of the present work was to evaluate, by a ring trial, the sensitivity of the digestion method used at the National Reference Laboratories for Parasites (NRLP). These Laboratories are responsible for the quality of the detection method in their own country. Of the 27 EU countries, only three (Hungary, Luxembourg and Malta) did not participate in the ring trial. Each participating laboratory received 10 samples of 100g of minced pork containing 3-5 larvae (3 samples), 10-20 larvae (3 samples), 30-50 larvae (3 samples), and one negative control. In each positive sample, there were living Trichinella spiralis larvae without the collagen capsule, obtained by partial artificial digestion of muscle tissue from infected mice. No false positive sample was found in any laboratories, whereas nine laboratories (37.5%) failed to detect some positive samples with the percentage of false negatives ranging from 11 to 100%. The variation between expected and reported larval counts observed among the participating laboratories was statistically significant. There was a direct correlation between the consistency of the results and the use of a validated/accredited digestion method. Conversely, there was no correlation between the consistency of the results and the number of digestions performed yearly by the NRLP. These results support the importance of validating the test.

  4. Tank 241-AP-106, Grab samples, 6AP-98-1, 6AP-98-2 and 6AP-98-3 Analytical results for the final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    FULLER, R.K.

    1999-02-23

    This document is the final report for tank 241-AP-106 grab samples. Three grab samples 6AP-98-1, 6AP-98-2 and 6AP-98-3 were taken from riser 1 of tank 241-AP-106 on May 28, 1998 and received by the 222-S Laboratory on May 28, 1998. Analyses were performed in accordance with the ''Compatability Grab Sampling and Analysis Plan'' (TSAP) (Sasaki, 1998) and the ''Data Quality Objectives for Tank Farms Waste Compatability Program (DQO). The analytical results are presented in the data summary report. No notification limits were exceeded. The request for sample analysis received for AP-106 indicated that the samples were polychlorinated biphenyl (PCB) suspects.more » The results of this analysis indicated that no PCBs were present at the Toxic Substance Control Act (TSCA) regulated limit of 50 ppm. The results and raw data for the PCB analysis are included in this document.« less

  5. Does age affect the relationship between control at work and sleep disturbance for shift workers?

    PubMed

    Loudoun, Rebecca Jane; Muurlink, Olav; Peetz, David; Murray, Georgina

    2014-12-01

    Among miners, shift work, aging and lack of control at work may be factors leading to increased sleep problems. Such risk factors may also operate in interaction, resulting in an even increased harm for sleep disruption. The present study aims at evaluating these relationships drawing on a sample of Australian mine and energy workers and their partners. The workers were mainly men. All performed shift work that included either nights (95%) or multiple shifts (92%), usually both (87%), while 36% were aged 50 years or above. The results show that low latitude over work activities is associated with higher sleep disturbances across the sample, though the effects are clearer amongst younger workers. By contrast, for younger workers, control over shift scheduling is not associated with sleep disturbances but for workers aged 50 or more, low control results in more sleep disturbance. Misalignment between shift workers and partner work schedules, and partner dissatisfaction with shift worker's employment and shift worker's work-life balance, are also associated with more sleep disturbances amongst shift workers.

  6. Effects of select and reject control on equivalence class formation and transfer of function.

    PubMed

    Perez, William F; Tomanari, Gerson Y; Vaidya, Manish

    2015-09-01

    The present study used a single-subject design to evaluate the effects of select or reject control on equivalence class formation and transfer of function. Adults were exposed to a matching-to-sample task with observing requirements (MTS-OR) in order to bias the establishment of sample/S+ (select) or sample/S- (reject) relations. In Experiment 1, four sets of baseline conditional relations were taught-two under reject control (A1B2C1, A2B1C2) and two under select control (D1E1F1, D2E2F2). Participants were tested for transitivity, symmetry, equivalence and reflexivity. They also learned a simple discrimination involving one of the stimuli from the equivalence classes and were tested for the transfer of the discriminative function. In general, participants performed with high accuracy on all equivalence-related probes as well as the transfer of function probes under select control. Under reject control, participants had high scores only on the symmetry test; transfer of function was attributed to stimuli programmed as S-. In Experiment 2, the equivalence class under reject control was expanded to four members (A1B2C1D2; A2B1C2D1). Participants had high scores only on symmetry and on transitivity and equivalence tests involving two nodes. Transfer of function was extended to the programmed S- added to each class. Results from both experiments suggest that select and reject controls might differently affect the formation of equivalence classes and the transfer of stimulus functions. © Society for the Experimental Analysis of Behavior.

  7. Metabolomic Profiling of Post-Mortem Brain Reveals Changes in Amino Acid and Glucose Metabolism in Mental Illness Compared with Controls.

    PubMed

    Zhang, Rong; Zhang, Tong; Ali, Ali Muhsen; Al Washih, Mohammed; Pickard, Benjamin; Watson, David G

    2016-01-01

    Metabolomic profiling was carried out on 53 post-mortem brain samples from subjects diagnosed with schizophrenia, depression, bipolar disorder (SDB), diabetes, and controls. Chromatography on a ZICpHILIC column was used with detection by Orbitrap mass spectrometry. Data extraction was carried out with m/z Mine 2.14 with metabolite searching against an in-house database. There was no clear discrimination between the controls and the SDB samples on the basis of a principal components analysis (PCA) model of 755 identified or putatively identified metabolites. Orthogonal partial least square discriminant analysis (OPLSDA) produced clear separation between 17 of the controls and 19 of the SDB samples (R2CUM 0.976, Q2 0.671, p-value of the cross-validated ANOVA score 0.0024). The most important metabolites producing discrimination were the lipophilic amino acids leucine/isoleucine, proline, methionine, phenylalanine, and tyrosine; the neurotransmitters GABA and NAAG and sugar metabolites sorbitol, gluconic acid, xylitol, ribitol, arabinotol, and erythritol. Eight samples from diabetic brains were analysed, six of which grouped with the SDB samples without compromising the model (R2 CUM 0.850, Q2 CUM 0.534, p-value for cross-validated ANOVA score 0.00087). There appears on the basis of this small sample set to be some commonality between metabolic perturbations resulting from diabetes and from SDB.

  8. Automated MALDI Matrix Coating System for Multiple Tissue Samples for Imaging Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Mounfield, William P.; Garrett, Timothy J.

    2012-03-01

    Uniform matrix deposition on tissue samples for matrix-assisted laser desorption/ionization (MALDI) is key for reproducible analyte ion signals. Current methods often result in nonhomogenous matrix deposition, and take time and effort to produce acceptable ion signals. Here we describe a fully-automated method for matrix deposition using an enclosed spray chamber and spray nozzle for matrix solution delivery. A commercial air-atomizing spray nozzle was modified and combined with solenoid controlled valves and a Programmable Logic Controller (PLC) to control and deliver the matrix solution. A spray chamber was employed to contain the nozzle, sample, and atomized matrix solution stream, and to prevent any interference from outside conditions as well as allow complete control of the sample environment. A gravity cup was filled with MALDI matrix solutions, including DHB in chloroform/methanol (50:50) at concentrations up to 60 mg/mL. Various samples (including rat brain tissue sections) were prepared using two deposition methods (spray chamber, inkjet). A linear ion trap equipped with an intermediate-pressure MALDI source was used for analyses. Optical microscopic examination showed a uniform coating of matrix crystals across the sample. Overall, the mass spectral images gathered from tissues coated using the spray chamber system were of better quality and more reproducible than from tissue specimens prepared by the inkjet deposition method.

  9. Automated MALDI matrix coating system for multiple tissue samples for imaging mass spectrometry.

    PubMed

    Mounfield, William P; Garrett, Timothy J

    2012-03-01

    Uniform matrix deposition on tissue samples for matrix-assisted laser desorption/ionization (MALDI) is key for reproducible analyte ion signals. Current methods often result in nonhomogenous matrix deposition, and take time and effort to produce acceptable ion signals. Here we describe a fully-automated method for matrix deposition using an enclosed spray chamber and spray nozzle for matrix solution delivery. A commercial air-atomizing spray nozzle was modified and combined with solenoid controlled valves and a Programmable Logic Controller (PLC) to control and deliver the matrix solution. A spray chamber was employed to contain the nozzle, sample, and atomized matrix solution stream, and to prevent any interference from outside conditions as well as allow complete control of the sample environment. A gravity cup was filled with MALDI matrix solutions, including DHB in chloroform/methanol (50:50) at concentrations up to 60 mg/mL. Various samples (including rat brain tissue sections) were prepared using two deposition methods (spray chamber, inkjet). A linear ion trap equipped with an intermediate-pressure MALDI source was used for analyses. Optical microscopic examination showed a uniform coating of matrix crystals across the sample. Overall, the mass spectral images gathered from tissues coated using the spray chamber system were of better quality and more reproducible than from tissue specimens prepared by the inkjet deposition method.

  10. Association of rs1344706 in the ZNF804A gene with schizophrenia in a case/control sample from Indonesia.

    PubMed

    Schwab, Sibylle G; Kusumawardhani, Agung A A A; Dai, Nan; Qin, WenWen; Wildenauer, Mutiara D B; Agiananda, Feranindhya; Amir, Nurmiati; Antoni, Ronald; Arsianti, Tiana; Asmarahadi, Asmarahadi; Diatri, Hervita; Djatmiko, Prianto; Irmansyah, Irmansyah; Khalimah, Siti; Kusumadewi, Irmia; Kusumaningrum, Profitasari; Lukman, Petrin R; Mustar, Lukman; Nasrun, Martina W; Naswati, Safyuni; Prasetiyawan, Prasetiyawan; Semen, Gerald M; Siste, Kristiana; Tobing, Heriani; Widiasih, Natalia; Wiguna, Tjhin; Wulandari, Widayanti Dewi; Benyamin, Beben; Wildenauer, Dieter B

    2013-06-01

    Association of rs1344706 in the ZNF804A gene (2q32.1) with schizophrenia was first reported in a genome wide scan conducted in a sample of 479 cases and replicated in 6666 cases. Subsequently, evidence by replication was obtained in several samples with European- and Asian ancestral background. We report ascertainment, clinical characterization, quality control, and determination of ancestral background of a case control sample from Indonesia, comprising 1067 cases and 1111 ancestry matched controls. Genotyping was performed using a fluorescence-based allelic discrimination assay (TaqMan SNP genotyping assay) and a newly designed PCR-RFLP assay for confirmation of rs1344706 genotypes. We confirmed association of the T-allele of rs1344706 with schizophrenia in a newly ascertained sample from Indonesia with Southeast Asian ancestral background (P=0.019, OR=1.155, 95%, CI 1.025-1.301). In addition, we studied several SNPs in the vicinity of rs1344706, for which nominally significant results had been reported. None of the association P values of the additional SNPs exceeded that of rs1344706. We provide additional evidence for association of the ZNF804A gene with schizophrenia. We conclude that rs1344706 or a yet unknown polymorphism in linkage disequilibrium is also involved in conferring susceptibility to schizophrenia in samples with different (Asian) ancestral backgrounds. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Cognitive tasks promote automatization of postural control in young and older adults.

    PubMed

    Potvin-Desrochers, Alexandra; Richer, Natalie; Lajoie, Yves

    2017-09-01

    Researchers looking at the effects of performing a concurrent cognitive task on postural control in young and older adults using traditional center-of-pressure measures and complexity measures found discordant results. Results of experiments showing improvements of stability have suggested the use of strategies such as automatization of postural control or stiffening strategy. This experiment aimed to confirm in healthy young and older adults that performing a cognitive task while standing leads to improvements that are due to automaticity of sway by using sample entropy. Twenty-one young adults and twenty-five older adults were asked to stand on a force platform while performing a cognitive task. There were four cognitive tasks: simple reaction time, go/no-go reaction time, equation and occurrence of a digit in a number sequence. Results demonstrated decreased sway area and variability as well as increased sample entropy for both groups when performing a cognitive task. Results suggest that performing a concurrent cognitive task promotes the adoption of an automatic postural control in young and older adults as evidenced by an increased postural stability and postural sway complexity. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. A controlled family study of cannabis users with and without psychosis.

    PubMed

    Proal, Ashley C; Fleming, Jerry; Galvez-Buccollini, Juan A; Delisi, Lynn E

    2014-01-01

    Cannabis is one of the most highly abused illicit drugs in the world. Several studies suggest a link between adolescent cannabis use and schizophrenia. An understanding of this link would have significant implications for legalization of cannabis and its medicinal value. The present study aims to determine whether familial morbid risk for schizophrenia is the crucial factor that underlies the association of adolescent cannabis use with the development of schizophrenia. Consecutively obtained probands were recruited into four samples: sample 1: 87 non-psychotic controls with no drug use; sample 2: 84 non-psychotic controls with cannabis use; sample 3: 32 patients with a schizophrenia spectrum psychosis with no drug use; sample 4: 76 patients with schizophrenia spectrum psychosis with cannabis use. All cannabis using subjects used this drug during adolescence, and no other substance, with the exception of alcohol. Structured interviews of probands and family informants were used to obtain diagnostic information about probands and all their known relatives. There was an increased morbid risk for schizophrenia in relatives of the cannabis using and non-using patient samples compared with their respective non-psychotic control samples (p=.002, p<.001 respectively). There was no significant difference in morbid risk for schizophrenia between relatives of the patients who use or do not use cannabis (p=.43). The results of the current study suggest that having an increased familial morbid risk for schizophrenia may be the underlying basis for schizophrenia in cannabis users and not cannabis use by itself. Published by Elsevier B.V.

  13. Improving Ambulatory Saliva-Sampling Compliance in Pregnant Women: A Randomized Controlled Study

    PubMed Central

    Moeller, Julian; Lieb, Roselind; Meyer, Andrea H.; Loetscher, Katharina Quack; Krastel, Bettina; Meinlschmidt, Gunther

    2014-01-01

    Objective Noncompliance with scheduled ambulatory saliva sampling is common and has been associated with biased cortisol estimates in nonpregnant subjects. This study is the first to investigate in pregnant women strategies to improve ambulatory saliva-sampling compliance, and the association between sampling noncompliance and saliva cortisol estimates. Methods We instructed 64 pregnant women to collect eight scheduled saliva samples on two consecutive days each. Objective compliance with scheduled sampling times was assessed with a Medication Event Monitoring System and self-reported compliance with a paper-and-pencil diary. In a randomized controlled study, we estimated whether a disclosure intervention (informing women about objective compliance monitoring) and a reminder intervention (use of acoustical reminders) improved compliance. A mixed model analysis was used to estimate associations between women's objective compliance and their diurnal cortisol profiles, and between deviation from scheduled sampling and the cortisol concentration measured in the related sample. Results Self-reported compliance with a saliva-sampling protocol was 91%, and objective compliance was 70%. The disclosure intervention was associated with improved objective compliance (informed: 81%, noninformed: 60%), F(1,60)  = 17.64, p<0.001, but not the reminder intervention (reminders: 68%, without reminders: 72%), F(1,60)  = 0.78, p = 0.379. Furthermore, a woman's increased objective compliance was associated with a higher diurnal cortisol profile, F(2,64) = 8.22, p<0.001. Altered cortisol levels were observed in less objective compliant samples, F(1,705) = 7.38, p = 0.007, with delayed sampling associated with lower cortisol levels. Conclusions The results suggest that in pregnant women, objective noncompliance with scheduled ambulatory saliva sampling is common and is associated with biased cortisol estimates. To improve sampling compliance, results suggest informing women about objective compliance monitoring but discourage use of acoustical reminders. PMID:24465958

  14. Rapid Communication: MiR-92a as a housekeeping gene for analysis of bovine mastitis-related microRNA in milk.

    PubMed

    Lai, Y C; Fujikawa, T; Ando, T; Kitahara, G; Koiwa, M; Kubota, C; Miura, N

    2017-06-01

    Our aim was to identify a suitable microRNA housekeeping gene for real-time PCR analysis of bovine mastitis-related microRNA in milk. We identified , , and as housekeeping gene candidates on the basis of previous Solexa sequencing results. Threshold cycle (CT) values for , , and did not differ between milk from control cows and milk from mastitis-affected cows. NormFinder software identified as the most stable single housekeeping gene. We evaluated the suitability of the housekeeping gene candidates by using them to assess expression levels of the inflammation-related gene . Regardless of the housekeeping gene candidates used for normalization, relative expression levels of were significantly higher in mastitis-affected samples than in control samples. However, of all the housekeeping genes and gene combinations investigated, normalization with alone generated the difference in relative expression between mastitis-affected and control samples with the highest significance. These results suggest that is suitable for use as a housekeeping gene for analysis of bovine mastitis-related microRNA in milk.

  15. The neural networks of inhibitory control in posttraumatic stress disorder

    PubMed Central

    Falconer, Erin; Bryant, Richard; Felmingham, Kim L.; Kemp, Andrew H.; Gordon, Evian; Peduto, Anthony; Olivieri, Gloria; Williams, Leanne M.

    2008-01-01

    Objective Posttraumatic stress disorder (PTSD) involves deficits in information processing that may reflect hypervigilence and deficient inhibitory control. To date, however, no PTSD neuroimaging study has directly examined PTSD-related changes in executive inhibition. Our objective was to investigate the hypothesis that executive inhibitory control networks are compromised in PTSD. Methods Functional magnetic resonance imaging (fMRI) was used during a Go/No-Go inhibition task completed by a sample of patients with PTSD (n = 23), a matched sample of healthy (i.e. without trauma exposure) control participants (n = 23) and a sample of control participants with trauma exposure who did not meet criteria for PTSD (n = 17). Results Participants with PTSD showed more inhibition-related errors than did individuals without trauma exposure. During inhibition, control participants activated a right-lateralized cortical inhibitory network, whereas patients with PTSD activated only the left lateral frontal cortex. PTSD was associated with a reduction in right cortical activation and increased activation of striatal and somatosensory regions. Conclusion The increased inhibitory error and reduced right frontal cortical activation are consistent with compromised inhibitory control in PTSD, while the increased activation of brain regions associated with sensory processing and a greater demand on inhibitory control may reflect enhanced stimulus processing in PTSD, which may undermine cortical control mechanisms. PMID:18787658

  16. Voltage-Controlled Spray Deposition of Multiwalled Carbon Nanotubes on Semiconducting and Insulating Substrates

    NASA Astrophysics Data System (ADS)

    Maulik, Subhodip; Sarkar, Anirban; Basu, Srismrita; Daniels-Race, Theda

    2018-05-01

    A facile, cost-effective, voltage-controlled, "single-step" method for spray deposition of surfactant-assisted dispersed carbon nanotube (CNT) thin films on semiconducting and insulating substrates has been developed. The fabrication strategy enables direct deposition and adhesion of CNT films on target samples, eliminating the need for substrate surface functionalization with organosilane binder agents or metal layer coatings. Spray coating experiments on four types of sample [bare silicon (Si), microscopy-grade glass samples, silicon dioxide (SiO2), and polymethyl methacrylate (PMMA)] under optimized control parameters produced films with thickness ranging from 40 nm to 6 μm with substantial surface coverage and packing density. These unique deposition results on both semiconducting and insulator target samples suggest potential applications of this technique in CNT thin-film transistors with different gate dielectrics, bendable electronics, and novel CNT-based sensing devices, and bodes well for further investigation into thin-film coatings of various inorganic, organic, and hybrid nanomaterials on different types of substrate.

  17. A survey of occupational exposure to 4,4'-methylene-bis (2-chloroaniline) (MbOCA) in the UK.

    PubMed

    Cocker, J; Cain, J R; Baldwin, P; McNally, K; Jones, K

    2009-07-01

    The main objective of the study was to gather information about the current controls and levels of exposure to 4,4'-methylene-bis (2-chloroaniline) (MbOCA) in a representative cross section of workplaces that use it to manufacture polyurethane elastomers. The study also aimed to investigate whether controls and guidance could be improved and to investigate exposure to isocyanates in these workplaces using biological monitoring. An occupational hygienist and a field scientist visited the two UK suppliers and 20 out of the 25 workplaces known to be using MbOCA in the UK during 2005 and 2006. They collected air samples, surface wipes, gloves, and urine samples and made observations to assess exposure and the adequacy of controls. All samples were analysed for MbOCA and urine samples were additionally analysed for isocyanate metabolites. A statistical analysis was made of the results. Only 2.5% of the 80 personal inhalation exposures to MbOCA exceeded the workplace exposure limit of 5 microg m(-3) 8-h time-weighted average and 84% were below the limit of detection (LOD). Surface samples (n = 334) were collected from MbOCA users and suppliers and 60% had detectable levels of MbOCA ranging from 0.019 to 400 microg cm(-2). The highest levels were around a hopper, ovens, and the weighing and pouring areas. MbOCA was also detected in 8 of the 75 samples collected from areas not likely to be in contact with MbOCA. At the two suppliers, samples (n = 28) were collected from the outside surfaces of recently imported kegs, pallets, and the floor around kegs. Six samples had detectable levels and four of these (0.2, 0.8, 1, and 6 microg cm(-2)) were from the floor and pallets in both suppliers. The other two positive results were found on the outside rim (18 microg cm(-2)) and side (23 microg cm(-2)) of a keg at one supplier indicating contamination by the manufacturer. Urine samples (n = 79) were collected and 49% were below the LOD for MbOCA and only three samples had levels of MbOCA that exceeded the biological monitoring guidance value (BMGV) of 15 micromol mol(-1) creatinine. The highest urinary MbOCA concentrations were in samples from workers casting and moulding. The 90th percentile of the urine MbOCA results was 8.6 micromol MbOCA per mol creatinine. Urine samples were also analysed for the diamine metabolites of toluene diisocyanate and hexamethylene diisocyanate and 33% had detectable levels with 22 and 13% of results, respectively, above the BMGV for isocyanates (1 micromol isocyanate-derived diamine per mol creatinine). The maximum urinary concentration of toluene diamine and hexane diamine were 15.6 and 10.1 micromol mol(-1) creatinine, respectively. The survey found that the measures used to control exposure to MbOCA could be improved. Although air levels of MbOCA were generally low, there was evidence of spread of surface contamination and poor maintenance of controls such as local exhaust ventilation. A BMGV based on the 90th percentile of data from workplaces with good control would be less than the 90% value of 8.6 micromol mol(-1) creatinine found in this study and suggests that the current BMGV of 15 micromol mol(-1) creatinine is no longer acting as a stimulus to reduce exposure. The metabolites of isocyanates found in urine samples in this study could arise from inhalation exposure to isocyanates or from dermal exposure to either isocyanates or their diamine breakdown product and need further investigation.

  18. What Contributes to Self-Control and Grit?: The Key Factors in College Students

    ERIC Educational Resources Information Center

    Sriram, Rishi; Glanzer, Perry L.; Allen, Cara Cliburn

    2018-01-01

    Although scholars know an increasing amount about the benefits of self-control and grit for college students, they know less about what influences self-control and grit in students. In this study we examined influences on self-control and a key element of grit in a national sample of college students. Results indicated that 5 of the 13 predictor…

  19. Exponential synchronization of neural networks with discrete and distributed delays under time-varying sampling.

    PubMed

    Wu, Zheng-Guang; Shi, Peng; Su, Hongye; Chu, Jian

    2012-09-01

    This paper investigates the problem of master-slave synchronization for neural networks with discrete and distributed delays under variable sampling with a known upper bound on the sampling intervals. An improved method is proposed, which captures the characteristic of sampled-data systems. Some delay-dependent criteria are derived to ensure the exponential stability of the error systems, and thus the master systems synchronize with the slave systems. The desired sampled-data controller can be achieved by solving a set of linear matrix inequalitys, which depend upon the maximum sampling interval and the decay rate. The obtained conditions not only have less conservatism but also have less decision variables than existing results. Simulation results are given to show the effectiveness and benefits of the proposed methods.

  20. Economic consequences of improved temperature forecasts: An experiment with the Florida citrus growers (control group results). [weather forecasting

    NASA Technical Reports Server (NTRS)

    1977-01-01

    A demonstration experiment is being planned to show that frost and freeze prediction improvements are possible utilizing timely Synchronous Meteorological Satellite temperature measurements and that this information can affect Florida citrus grower operations and decisions. An economic experiment was carried out which will monitor citrus growers' decisions, actions, costs and losses, and meteorological forecasts and actual weather events and will establish the economic benefits of improved temperature forecasts. A summary is given of the economic experiment, the results obtained to date, and the work which still remains to be done. Specifically, the experiment design is described in detail as are the developed data collection methodology and procedures, sampling plan, data reduction techniques, cost and loss models, establishment of frost severity measures, data obtained from citrus growers, National Weather Service, and Federal Crop Insurance Corp., resulting protection costs and crop losses for the control group sample, extrapolation of results of control group to the Florida citrus industry and the method for normalization of these results to a normal or average frost season so that results may be compared with anticipated similar results from test group measurements.

  1. Nutritional characterisation of Pleurotus ostreatus (Jacq. ex Fr.) P. Kumm. produced using paper scraps as substrate.

    PubMed

    Fernandes, Ângela; Barros, Lillian; Martins, Anabela; Herbert, Paulo; Ferreira, Isabel C F R

    2015-02-15

    Pleurotus ostreatus (Jacq. ex Fr.) P. Kumm. is the third most produced edible mushroom worldwide, due to its ability to colonise and degrade a large variety of lignocellulosic substrates. Therefore, the objective of this work was to evaluate the chemical composition of fruiting bodies of P. ostreatus grown on blank and printed paper substrates, in comparison with samples grown on oat straw (control). The nutritional properties of the control sample were similar to values reported in the literature, while the chemical composition of the samples obtained using paper scraps, either blank or printed, was highly satisfactory. The results obtained validated the nutritional characteristics of the samples, highlighting a profitable means to recycle paper. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Evaluation of effect of addition of 2% chlorhexidine on the sealing ability of Biodentine: An in vitro study

    PubMed Central

    Suri, Navleen Kaur; Nikhil, Vineeta; Jha, Padmanabh; Jaiswal, Shikha

    2015-01-01

    Aim: To evaluate the effect of the addition of 2% chlorhexidine on the sealing ability of Biodentine. Materials and Methods: Forty-six extracted human premolar teeth with single canal and apical foramen were selected, cleaned, and decoronated to standardize the length of 17 mm. Canals were prepared using ProTaper rotary files till size F4. The samples were divided into 2 experimental groups of 20 samples each on the basis of absence/presence of 2% chlorhexidine in liquid: Group BM = Biodentine mixed with the provided liquid, Group BC = Biodentine mixed with 2% chlorhexidine in provided liquid. Three samples, each were assigned to control groups: Group BP (positive control) = No root end filling was placed, Group BN (negative control) = Root ends were filled as in Group BM, and entire external surface was coated with sticky wax. The samples were then evaluated for the apical sealing using fluid filtration method. Results: Results were analyzed using Student's t-test (P ≤ 0.05). Group BC showed the better sealing ability (3.06) as compared to Group BM (3.85). However, the difference was statistically insignificant (P > 0.05). Conclusion: Addition of 2% chlorhexidine to the liquid enhanced the sealing ability of Biodentine. PMID:26752844

  3. The MicroActive project: automatic detection of disease-related molecular cell activity

    NASA Astrophysics Data System (ADS)

    Furuberg, Liv; Mielnik, Michal; Johansen, Ib-Rune; Voitel, Jörg; Gulliksen, Anja; Solli, Lars; Karlsen, Frank; Bayer, Tobias; Schönfeld, Friedhelm; Drese, Klaus; Keegan, Helen; Martin, Cara; O'Leary, John; Riegger, Lutz; Koltay, Peter

    2007-05-01

    The aim of the MicroActive project is to develop an instrument for molecular diagnostics. The instrument will first be tested for patient screening for a group of viruses causing cervical cancer. Two disposable polymer chips with reagents stored on-chip will be inserted into the instrument for each patient sample. The first chip performs sample preparation of the epithelial cervical cells while mRNA amplification and fluorescent detection takes place in the second chip. More than 10 different virus markers will be analysed in one chip. We report results on sub-functions of the amplification chip. The sample is split into smaller droplets, and the droplets move in parallel channels containing different dried reagents for the different analyses. We report experimental results on parallel droplet movement control using one external pump only, combined with hydrophobic valves. Valve burst pressures are controlled by geometry. We show droplet control using valves with burst pressures between 800 and 4500 Pa. We also monitored the re-hydration times for two necessary dried reagents. After sample insertion, uniform concentration of the reagents in the droplet was reached after respectively 60 s and 10 min. These times are acceptable for successful amplification. Finally we have shown positive amplification of HPV type 16 using dried enzymes stored in micro chambers.

  4. Verification of radio frequency pasteurization treatment for controlling Aspergillus parasiticus on corn grains.

    PubMed

    Zheng, Ajuan; Zhang, Lihui; Wang, Shaojin

    2017-05-16

    Radio frequency (RF) heating has been proposed and tested to achieve a required anti-fungal efficacy on various food samples due to its advantage of deeper penetration depth and better heating uniformity. The purpose of this study was to validate applications of RF treatments for controlling Aspergillus parasiticus in corn while maintaining product quality. A pilot-scale, 27.12MHz, 6kW RF heating system together with hot air heating was used to rapidly pasteurize 3.0kg corn samples. Results showed that the pasteurizing effect of RF heating on Aspergillus parasiticus increased with increasing heating temperature and holding time, and RF heating at 70°C holding in hot air for at least 12min resulted in 5-6 log reduction of Aspergillus parasiticus in corn samples with the moisture content of 15.0% w.b. Furthermore, thermal resistance of Aspergillus parasiticus decreased with increasing moisture content (MC) of corn samples. Quality (MC, water activity - a w , protein, starch, ash, fat, fatty acid, color, electrical conductivity and germination rate) of RF treated corn met the required quality standard used in cereal industry. Therefore, RF treatments can provide an effective and rapid heating method to control Aspergillus parasiticus and maintain acceptable corn quality. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Cross-Reactivity of Chloroquine and Hydroxychloroquine With DRI Amphetamine Immunoassay.

    PubMed

    Gomila, Isabel; Quesada, Loreto; López-Corominas, Victoria; Fernández, Julia; Servera, Miguel Á; Sahuquillo, Laura; Dastis, Macarena; Torrents, Albert; Barceló, Bernardino

    2017-04-01

    Chloroquine and hydroxychloroquine are medical drugs used to treat the chemoprophylaxis of malaria and a second-line anti-inflammatory drug. We performed a study of cross-reactivity of chloroquine and hydroxychloroquine in the DRI Amphetamine Assay inspired by a case report of a self-ingestion of chloroquine after a family dispute, that involved the following: (1) an in vitro study with control samples of healthy subjects, (2) an in vivo study with samples of patients with rheumatoid arthritis, and (3) an evaluation of the cross-reactivity of chloroquine and hydroxychloroquine in 3 additional immunoassays. In the case report, the Amphetamine DRI assay resulted positive both at 1000 ng/mL cutoff (1507 and 1137 ng/mL) and at 500 ng/mL cutoff (1178 and 642 ng/mL). Chloroquine urine levels were 103,900 and 100,900 ng/mL at 5 and 9 hours after ingestion. The results with control samples showed a positive cross-reactivity of chloroquine in the DRI Amphetamine Assay (approximately 0.74% and 0.89% at cutoff of 1000 and 500 ng/mL, respectively). Hydroxychloroquine did not cross-react with the DRI Amphetamine Assay up to 1,000,000 ng/mL. In patients treated with chloroquine or hydroxychloroquine, DRI Amphetamine did not produce false-positive results. The comparative assay study showed a positive cross-reactivity of chloroquine in the Emit II Plus Amphetamines Assay with control samples. Chloroquine can cause false-positive results in the DRI Amphetamine Assay when it is present at high concentrations. Hydroxychloroquine did not produce false-positive results neither in the DRI Amphetamine Assay nor in the others immunoassays evaluated.

  6. Childrearing Style of Anxiety-Disordered Parents

    ERIC Educational Resources Information Center

    Lindhout, Ingeborg; Markus, Monica; Hoogendijk, Thea; Borst, Sophie; Maingay, Ragna; Spinhoven, Philip; van Dyck, Richard; Boer, Frits

    2006-01-01

    This study investigated whether anxiety-disordered (AD) parents differ in their childrearing style from non-disordered parents. A clinical sample of 36 AD parents with children aged 6-18 was compared with a normal control sample of 36 parents. Childrearing was assessed through parent report and child report. The results demonstrated significant…

  7. Passivation of pigment particles for thermal control coatings

    NASA Technical Reports Server (NTRS)

    Sancier, K. M.; Morrison, S. R.; Farley, E. P.

    1975-01-01

    The preparation of a matrix of 48 samples consisting of pigments and pigmented paints is described. The results obtained from testing these samples by electron spin resonance and by in situ spectral reflectance measurements in space simulation tests are presented. Conclusions and recommendations for further research are given.

  8. Corticosteroid therapy and airflow obstruction influence the bronchial microbiome, which is distinct from that of bronchoalveolar lavage in asthmatic airways

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Denner, Darcy R.; Sangwan, Naseer; Becker, Julia B.

    The lung has a diverse microbiome that is modest in biomass. This microbiome differs in asthmatic patients compared with control subjects, but the effects of clinical characteristics on the microbial community composition and structure are not clear. OBJECTIVES: We examined whether the composition and structure of the lower airway microbiome correlated with clinical characteristics of chronic persistent asthma, including airflow obstruction, use of corticosteroid medications, and presence of airway eosinophilia. METHODS: DNA was extracted from endobronchial brushings and bronchoalveolar lavage fluid collected from 39 asthmatic patients and 19 control subjects, along with negative control samples. 16S rRNA V4 amplicon sequencingmore » was used to compare the relative abundance of bacterial genera with clinical characteristics. RESULTS: Differential feature selection analysis revealed significant differences in microbial diversity between brush and lavage samples from asthmatic patients and control subjects. Lactobacillus, Pseudomonas, and Rickettsia species were significantly enriched in samples from asthmatic patients, whereas Prevotella, Streptococcus, and Veillonella species were enriched in brush samples from control subjects. Generalized linear models on brush samples demonstrated oral corticosteroid use as an important factor affecting the relative abundance of the taxa that were significantly enriched in asthmatic patients. In addition, bacterial α-diversity in brush samples from asthmatic patients was correlated with FEV1 and the proportion of lavage eosinophils. CONCLUSION: The diversity and composition of the bronchial airway microbiome of asthmatic patients is distinct from that of nonasthmatic control subjects and influenced by worsening airflow obstruction and corticosteroid use. Copyright © 2015 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.« less

  9. Adaptive Neural Network-Based Event-Triggered Control of Single-Input Single-Output Nonlinear Discrete-Time Systems.

    PubMed

    Sahoo, Avimanyu; Xu, Hao; Jagannathan, Sarangapani

    2016-01-01

    This paper presents a novel adaptive neural network (NN) control of single-input and single-output uncertain nonlinear discrete-time systems under event sampled NN inputs. In this control scheme, the feedback signals are transmitted, and the NN weights are tuned in an aperiodic manner at the event sampled instants. After reviewing the NN approximation property with event sampled inputs, an adaptive state estimator (SE), consisting of linearly parameterized NNs, is utilized to approximate the unknown system dynamics in an event sampled context. The SE is viewed as a model and its approximated dynamics and the state vector, during any two events, are utilized for the event-triggered controller design. An adaptive event-trigger condition is derived by using both the estimated NN weights and a dead-zone operator to determine the event sampling instants. This condition both facilitates the NN approximation and reduces the transmission of feedback signals. The ultimate boundedness of both the NN weight estimation error and the system state vector is demonstrated through the Lyapunov approach. As expected, during an initial online learning phase, events are observed more frequently. Over time with the convergence of the NN weights, the inter-event times increase, thereby lowering the number of triggered events. These claims are illustrated through the simulation results.

  10. Identification of Chinese medicinal fungus Cordyceps sinensis by depth-profiling mid-infrared photoacoustic spectroscopy

    NASA Astrophysics Data System (ADS)

    Du, Changwen; Zhou, Jianmin; Liu, Jianfeng

    2017-02-01

    With increased demand for Cordyceps sinensis it needs rapid methods to meet the challenge of identification raised in quality control. In this study Cordyceps sinensis from four typical natural habitats in China was characterized by depth-profiling Fourier transform infrared photoacoustic spectroscopy. Results demonstrated that Cordyceps sinensis samples resulted in typical photoacoustic spectral appearance, but heterogeneity was sensed in the whole sample; due to the heterogeneity Cordyceps sinensis was represented by spectra of four groups including head, body, tail and leaf under a moving mirror velocity of 0.30 cm s- 1. The spectra of the four groups were used as input of a probabilistic neural network (PNN) to identify the source of Cordyceps sinensis, and all the samples were correctly identified by the PNN model. Therefore, depth-profiling Fourier transform infrared photoacoustic spectroscopy provides novel and unique technique to identify Cordyceps sinensis, which shows great potential in quality control of Cordyceps sinensis.

  11. Cultural Challenges Faced by American Mission Control Personnel Working with International Partners

    NASA Technical Reports Server (NTRS)

    Clement, J. L.; Ritsher, J. B.

    2006-01-01

    Operating the International Space Station (ISS) involves an indefinite, continuous series of long-duration international missions, and this requires an unprecedented degree of cooperation across multiple sites, organizations, and nations. Both junior and senior mission control personnel have had to find ways to address the cultural challenges inherent in such work, but neither have had systematic training in how to do so. The goals of this study were to identify and evaluate the major cultural challenges faced by ISS mission control personnel and to highlight the approaches that they have found most effective to surmount these challenges. We pay particular attention to the approaches successfully employed by the senior personnel and the training needs identified by the junior personnel. We also evaluate the extent to which the identified approaches and needs are consistent across the two samples. METHODS: Participants included a sample of 14 senior ISS flight controllers and a contrasting sample of 12 more junior controllers. All participants were mission operations specialists chosen on the basis of having worked extensively with international partners. Data were collected using a semi-structured qualitative interview and content analyzed using an iterative process with multiple coders and consensus meetings to resolve discrepancies. RESULTS: The senior respondents had substantial consensus on several cultural challenges and on key strategies for dealing with them, and they offered a wide range of specific tactics for implementing these strategies. Data from the junior respondents will be presented for the first time at the meeting. DISCUSSION: Although specific to American ISS personnel, our results are consistent with recent management, cultural, and aerospace research on other populations. We aim to use our results to improve training for current and future mission control personnel working in international or multicultural mission operations teams.

  12. Validation of the Korean version of the Eating Disorder Inventory-2: psychometric properties and cross-cultural comparison.

    PubMed

    Lee, Jung-Hyun; Shin, Mi-Yeon; Jo, Hye-Hyeon; Jung, Young-Chul; Kim, Joon-Ki; Kim, Kyung Ran

    2012-11-01

    The purpose of the present study was to examine the validity and reliability of the Korean version of the Eating Disorder Inventory-2 (EDI-2) in Korean patients with eating disorders and healthy controls, and to investigate cultural differences of EDI-2 between a Korean group and a North American standardization sample. The Korean version of the EDI-2 was prepared after comprehensive clinical assessment of Korean patients with eating disorders (n=327) as well as female undergraduates (n=176). Results were compared between eating disorder subgroups (anorexia nervosa, bulimia nervosa and eating disorders not otherwise specified) and those of a North American standardization sample and healthy controls. The results showed that the Korean EDI-2 had adequate internal consistency (0.77-0.93) and discriminated well between patients with eating disorders and healthy controls on all subscales. Significant differences in EDI-2 subscale scores between the eating disorder groups and the healthy control group were observed; however, there was no discernible difference among the eating disorder subgroups. When compared with a North American standardization sample, the Korean control group showed significantly higher scores for drive for thinness and asceticism. When patient groups were compared, the Korean group showed significantly lower scores for perfectionism. As expected, the results accurately reflected psychometric properties of the Korean version of EDI-2 for eating disorder patients in Korea. These findings also suggest that common characteristics for the eating disorder exist as a whole rather than with significant difference between each subgroup. In addition, significant differences between the Korean and the North American groups for both patients and controls also demonstrated specific cultural differences.

  13. Enhanced and effective conformational sampling of protein molecular systems for their free energy landscapes.

    PubMed

    Higo, Junichi; Ikebe, Jinzen; Kamiya, Narutoshi; Nakamura, Haruki

    2012-03-01

    Protein folding and protein-ligand docking have long persisted as important subjects in biophysics. Using multicanonical molecular dynamics (McMD) simulations with realistic expressions, i.e., all-atom protein models and an explicit solvent, free-energy landscapes have been computed for several systems, such as the folding of peptides/proteins composed of a few amino acids up to nearly 60 amino-acid residues, protein-ligand interactions, and coupled folding and binding of intrinsically disordered proteins. Recent progress in conformational sampling and its applications to biophysical systems are reviewed in this report, including descriptions of several outstanding studies. In addition, an algorithm and detailed procedures used for multicanonical sampling are presented along with the methodology of adaptive umbrella sampling. Both methods control the simulation so that low-probability regions along a reaction coordinate are sampled frequently. The reaction coordinate is the potential energy for multicanonical sampling and is a structural identifier for adaptive umbrella sampling. One might imagine that this probability control invariably enhances conformational transitions among distinct stable states, but this study examines the enhanced conformational sampling of a simple system and shows that reasonably well-controlled sampling slows the transitions. This slowing is induced by a rapid change of entropy along the reaction coordinate. We then provide a recipe to speed up the sampling by loosening the rapid change of entropy. Finally, we report all-atom McMD simulation results of various biophysical systems in an explicit solvent.

  14. The Relations of Temperament Reactivity and Effortful Control to Children's Adjustment Problems in China and the United States

    ERIC Educational Resources Information Center

    Zhou, Qing; Lengua, Liliana J.; Wang, Yun

    2009-01-01

    The relations of parents' and teachers' reports of temperament anger-irritability, positive emotionality, and effortful control (attention focusing and inhibitory control) to children's externalizing and internalizing problems were examined in Chinese (N = 382) and U.S. (N = 322) samples of school-age children. Results suggested that in both…

  15. Changes in Gene Expression Predicting Local Control in Cervical Cancer: Results from Radiation Therapy Oncology Group 0128

    PubMed Central

    Weidhaas, Joanne B.; Li, Shu-Xia; Winter, Kathryn; Ryu, Janice; Jhingran, Anuja; Miller, Bridgette; Dicker, Adam P.; Gaffney, David

    2009-01-01

    Purpose To evaluate the potential of gene expression signatures to predict response to treatment in locally advanced cervical cancer treated with definitive chemotherapy and radiation. Experimental Design Tissue biopsies were collected from patients participating in Radiation Therapy Oncology Group (RTOG) 0128, a phase II trial evaluating the benefit of celecoxib in addition to cisplatin chemotherapy and radiation for locally advanced cervical cancer. Gene expression profiling was done and signatures of pretreatment, mid-treatment (before the first implant), and “changed” gene expression patterns between pre- and mid-treatment samples were determined. The ability of the gene signatures to predict local control versus local failure was evaluated. Two-group t test was done to identify the initial gene set separating these end points. Supervised classification methods were used to enrich the gene sets. The results were further validated by leave-one-out and 2-fold cross-validation. Results Twenty-two patients had suitable material from pretreatment samples for analysis, and 13 paired pre- and mid-treatment samples were obtained. The changed gene expression signatures between the pre- and mid-treatment biopsies predicted response to treatment, separating patients with local failures from those who achieved local control with a seven-gene signature. The in-sample prediction rate, leave-one-out prediction rate, and 2-fold prediction rate are 100% for this seven-gene signature. This signature was enriched for cell cycle genes. Conclusions Changed gene expression signatures during therapy in cervical cancer can predict outcome as measured by local control. After further validation, such findings could be applied to direct additional therapy for cervical cancer patients treated with chemotherapy and radiation. PMID:19509178

  16. Investigating the Prevalence of Human Papilloma Virus in Squamous Cell Carcinoma of the Larynx and Its Correlation with Disease Prognosis

    PubMed Central

    Atighechi, Saeid; Meybodian, Mojtaba; Dadgarnia, Mohammad Hossein; Baradaranfar, Mohammad Hossein; Behniafard, Nasim

    2016-01-01

    Introduction: The human papilloma virus (HPV) can play a role in the development of head and neck squamous cell carcinoma (SCC). Our aim was to assess the prevalence of HPV DNA in SCC of the larynx. The impact of HPV infection on patient survival was also evaluated. Materials and Methods: This case-control study was performed in 44 patients with SCC of the larynx (case group), while the control group comprised samples obtained from cadavers with no previous history of malignancy. A preliminary pathologic evaluation was performed on all samples in the control group (36 samples) to ensure the absence of dysplasia or malignancy. Polymerase chain reaction (PCR) was used to detect HPV DNA. After completing the treatment protocol, patients were followed to assess the impact of HPV infection on overall survival (OS). Results: PCR evaluation in the case group showed that HPV DNA was successfully isolated from 11 (25%) samples, while only two (5.6%) HPV DNA-positive were obtained from cadavers. According to these results, a significant difference was obtained in the prevalence of HPV DNA and laryngeal SCC between cases and controls (P=0.031). No statistically significant difference was observed in the OS of patients with or without HPV infection in the case group (P=0.235). Conclusion: Based on these results, we suggest that the prevalence of HPV infection is higher in laryngeal SCC subjects compared with healthy individuals. Although a longer OS was seen in HPV-positive patients, survival analysis did not show a significant difference in the comparison of HPV-positive and negative findings in SCC patients. PMID:27429948

  17. Comparison of arterial and venous blood gases and the effects of analysis delay and air contamination on arterial samples in patients with chronic obstructive pulmonary disease and healthy controls.

    PubMed

    O'Connor, T M; Barry, P J; Jahangir, A; Finn, C; Buckley, B M; El-Gammal, A

    2011-01-01

    Arterial blood gases (ABGs) are often sampled incorrectly, leading to a 'mixed' or venous sample. Delays in analysis and air contamination are common. We measured the effects of these errors in patients with chronic obstructive pulmonary disease (COPD) exacerbations and controls. Arterial and venous samples were analyzed from 30 patients with COPD exacerbation and 30 controls. Venous samples were analysed immediately and arterial samples separated into non-air-contaminated and air-contaminated specimens and analysed at 0, 30, 60, 90 and 180 min. Mean venous pH was 7.371 and arterial pH was 7.407 (p < 0.0001). There was a correlation between venous and arterial pH (r = 0.5347, p < 0.0001). The regression equation to predict arterial pH was: arterial pH = 4.2289 + 0.43113 · venous pH. There were no clinically significant differences in arterial PO₂ associated with analysis delay. A statistically significant decline in pH was detected at 30 min in patients with COPD exacerbation (p = 0.0042) and 90 min in controls (p < 0.0001). A clinically significant decline in pH emerged at 73 min in patients with COPD exacerbation and 87 min in controls. Air contamination was associated with a clinically significant increase in PO₂ in all samples, including those that were immediately analyzed. Arterial and venous pH differ significantly. Venous pH cannot accurately replace arterial pH. Temporal delays in ABG analysis result in a significant decline in measured pH. ABGs should be analysed within 30 min. Air contamination leads to an immediate increase in measured PO₂, indicating that air-contaminated ABGs should be discarded. Copyright © 2010 S. Karger AG, Basel.

  18. The simultaneous detection of trivalent & hexavalent chromium in exhaled breath condensate: A feasibility study comparing workers and controls.

    PubMed

    Leese, Elizabeth; Morton, Jackie; Gardiner, Philip H E; Carolan, Vikki A

    2017-04-01

    The analytical method outlined in this feasibility study has been used to show that trivalent chromium (Cr(III)) and hexavalent chromium (Cr(VI)) can be detected and measured in exhaled breath condensate (EBC) samples. EBC samples and urine samples were collected from a cohort of 58 workers occupationally exposed to hexavalent chromium compounds and 22 unexposed volunteers (control group). Levels of Cr(III) and Cr(VI) were determined in EBC samples and total chromium levels were determined in urine samples. Pre and post working week samples for both EBC and urine were collected in tandem. Total chromium in urine samples was analysed by inductively coupled plasma mass spectrometry (ICP-MS). Analysis of Cr(III) and Cr(VI) in EBC samples used a hyphenated micro liquid chromatography (μLC) system coupled to an ICP-MS. Separation was achieved using an anion exchange micro-sized column. The results showed that the occupationally exposed workers had significantly higher levels of Cr(III) and Cr(VI) in their EBC samples than the control group, as well as higher levels of total chromium in their urine samples. However, for the exposed workers no significant difference was found between pre and post working week EBC samples for either Cr(III) or Cr(VI). This study has established that Cr(III) and Cr(VI) can simultaneously be detected and measured in 'real' EBC samples and will help in understanding inhalation exposure. Crown Copyright © 2016. Published by Elsevier GmbH. All rights reserved.

  19. Manganese and welding fume exposure and control in construction.

    PubMed

    Meeker, John D; Susi, Pam; Flynn, Michael R

    2007-12-01

    Overexposure to welding fume constituents, particularly manganese, is of concern in the construction industry due to the prevalence of welding and the scarcity of engineering controls. The control effectiveness of a commercially available portable local exhaust ventilation (LEV) unit was assessed. It consisted of a portable vacuum and a small bell-shaped hood connected by a flexible 2 inch (50.8 mm) diameter hose, in both experimental and field settings. The experimental testing was done in a semienclosed booth at a pipefitter training facility. Five paired trials of LEV control vs. no control, each approximately 1 hr in duration and conducted during two successive welds of 6 inch (152.4 mm) diameter carbon steel pipe were run in random order. Breathing zone samples were collected outside the welding hood during each trial. In the field scenario, full-shift breathing zone samples were collected from two pipefitters welding carbon steel pipe for a chiller installation on a commercial construction project. Eight days of full-shift sampling were conducted on both workers (n = 16), and the LEV was used by one of the two workers on an alternating basis for 7 of the days. All samples were collected with personal sample pumps calibrated at 2 L/min. Filter cassettes were analyzed for total particulate and manganese concentration by a certified laboratory. In the experimental setting, use of the portable LEV resulted in a 75% reduction in manganese exposure (mean 13 microg/m(3) vs. 51 microg/m(3); p < 0.05) and a 60% reduction in total particulate (mean 0.74 mg/m(3) vs. 1.83 mg/m(3); p < 0.05). In the field setting, LEV use resulted in a 53% reduction in manganese exposure (geometric mean 46 microg/m(3) vs. 97 microg/m(3); p < 0.05) but only a 10% reduction in total particulate (geometric mean 4.5 mg/m(3) vs. 5.0 mg/m(3); p > 0.05). These results demonstrate that LEV use can reduce manganese exposure associated with welding tasks in construction.

  20. Assessment of the application of an ecotoxicological procedure to screen illicit toxic discharges in domestic septic tank sludge.

    PubMed

    López-Gastey, J; Choucri, A; Robidoux, P Y; Sunahara, G I

    2000-06-01

    An innovative screening procedure has been developed to detect illicit toxic discharges in domestic septic tank sludge hauled to the Montreal Urban Community waste-water treatment plant. This new means of control is based on an integrative approach, using bioassays and chemical analyses. Conservative criteria are applied to detect abnormal toxicity with great reliability while avoiding false positive results. The complementary data obtained from toxicity tests and chemical analyses support the use of this efficient and easy-to-apply procedure. This study assesses the control procedure in which 231 samples were analyzed over a 30-month period. Data clearly demonstrate the deterrent power of an efficient control procedure combined with a public awareness campaign among the carriers. In the first 15 months of application, between January 1996 and March 1997, approximately 30% of the 123 samples analyzed showed abnormal toxicity. Between April 1997 and June 1998, that is, after a public hearing presentation of this procedure, this proportion dropped significantly to approximately 9% based on 108 analyzed samples. The results of a 30-month application of this new control procedure show the superior efficiency of the ecotoxicological approach compared with the previously used chemical control procedure. To be able to apply it effectively and, if necessary, to apply the appropriate coercive measures, ecotoxicological criteria should be included in regulatory guidelines.

  1. Quality-assurance plan for the analysis of fluvial sediment by the U.S. Geological Survey Kentucky Water Science Center Sediment Laboratory

    USGS Publications Warehouse

    Shreve, Elizabeth A.; Downs, Aimee C.

    2005-01-01

    This report describes laboratory procedures used by the U.S. Geological Survey Kentucky Water Science Center Sediment Laboratory for the processing and analysis of fluvial-sediment samples for concentration of sand and finer material. The report details the processing of a sediment sample through the laboratory from receiving the sediment sample, through the analytical process, to compiling results of the requested analysis. Procedures for preserving sample integrity, calibrating and maintaining of laboratory and field instruments and equipment, analyzing samples, internal quality assurance and quality control, and validity of the sediment-analysis results also are described. The report includes a list of references cited and a glossary of sediment and quality-assurance terms.

  2. An effective self-control strategy for the reduction of aflatoxin M1 content in milk and to decrease the exposure of consumers.

    PubMed

    Kerekes, Kata; Bonilauri, Paolo; Serraino, Andrea; Giacometti, Federica; Piva, Silvia; Zambrini, Vittorio; Canever, Alessandra; Farkas, Zsuzsa; Ambrus, Árpád

    2016-12-01

    The study reports the results of testing the sensitivity of an early warning sampling plan for detecting milk batches with high aflatoxin AFM 1 concentration. The effectiveness of the method was investigated by the analysis of 9017 milk samples collected in Italian milk processing plants that applied control plans with different action limits (AL). For those milk processing plants where 30 ng kg -1 AL has been applied, the AFM 1 contamination was significantly lower at or above the 95th percentile of the milk samples when compared with plants that used 40 ng kg -1 AL. The results show that the control plan can be used effectively for early warning of occurrence of high AFM 1 contamination of milk and to carry out pro-active measures to limit the level of contamination. Estimation of dietary exposure was also carried out, based on the aflatoxin M 1 content of the milk samples and on Italian food consumption data. Estimated Daily Intakes (EDI) and Hazard Indices (HI) were calculated for different age groups of the population. HIs show that no adverse effects are expected for the adult population, but in the case of children under age three, the approximate HI values were considerably higher. This underlines the importance of the careful monitoring and control of aflatoxin M 1 in milk and dairy products.

  3. The role of stress in the onset of depressive disorders. A controlled study in a Spanish clinical sample.

    PubMed

    Rojo-Moreno, L; Livianos-Aldana, L; Cervera-Martínez, G; Dominguez-Carabantes, J A; Reig-Cebrian, M J

    2002-12-01

    We conducted the present study to evaluate the impact of stressful events on the onset of depressive disorders in a Spanish clinical sample, compared to a control group matched for age, sex, civil status and social class. We compared our results with those of other studies carried out with samples that were both clinically and culturally similar to ours. Fifty depressed patients that were diagnosed with a depressive episode in the 6 months prior to the interview and 50 healthy controls were included in the study. Both groups were compared on the "Life Events and Difficulties Schedule" (LEDS). Of the depressive patients, 68 % compared to only 18 % of the control individuals experienced at least one provoking agent in the 12 months prior to the onset of the symptoms. The risk of developing a depressive disorder was 9.7 % greater in subjects exposed to such provoking agents. Chronic difficulties are equally important to the genesis of depressive disorders as severe life events. No significant differences were seen between the two diagnostic subgroups of depressed patients in the accumulation of severe events, major difficulties or provoking agents. The results support the view that stress is a major factor in the aetiology of depressive disorders. The amount of stress suffered by the patients, however, was less than that found in our healthy sample. Important issues about the model of interaction between stress and depression are discussed.

  4. Evaluating the Whitening and Microstructural Effects of a Novel Whitening Strip on Porcelain and Composite Dental Materials

    PubMed Central

    Takesh, Thair; Sargsyan, Anik; Lee, Matthew; Anbarani, Afarin; Ho, Jessica; Wilder-Smith, Petra

    2017-01-01

    Aims The aim of this project was to evaluate the effects of 2 different whitening strips on color, microstructure and roughness of tea stained porcelain and composite surfaces. Methods 54 porcelain and 72 composite chips served as samples for timed application of over-the-counter (OTC) test or control dental whitening strips. Chips were divided randomly into three groups of 18 porcelain and 24 composite chips each. Of these groups, 1 porcelain and 1 composite set served as controls. The remaining 2 groups were randomized to treatment with either Oral Essentials® Whitening Strips or Crest® 3D White Whitestrips™. Sample surface structure was examined by light microscopy, profilometry and Scanning Electron Microscopy (SEM). Additionally, a reflectance spectrophotometer was used to assess color changes in the porcelain and composite samples over 24 hours of whitening. Data points were analyzed at each time point using ANOVA. Results In the light microscopy and SEM images, no discrete physical defects were observed in any of the samples at any time points. However, high-resolution SEM images showed an appearance of increased surface roughness in all composite samples. Using profilometry, significantly increased post-whitening roughness was documented in the composite samples exposed to the control bleaching strips. Composite samples underwent a significant and equivalent shift in color following exposure to Crest® 3D White Whitestrips™ and Oral Essentials® Whitening Strips. Conclusions A novel commercial tooth whitening strip demonstrated a comparable beaching effect to a widely used OTC whitening strip. Neither whitening strip caused physical defects in the sample surfaces. However, the control strip caused roughening of the composite samples whereas the test strip did not. PMID:29226023

  5. Planning Robot-Control Parameters With Qualitative Reasoning

    NASA Technical Reports Server (NTRS)

    Peters, Stephen F.

    1993-01-01

    Qualitative-reasoning planning algorithm helps to determine quantitative parameters controlling motion of robot. Algorithm regarded as performing search in multidimensional space of control parameters from starting point to goal region in which desired result of robotic manipulation achieved. Makes use of directed graph representing qualitative physical equations describing task, and interacts, at each sampling period, with history of quantitative control parameters and sensory data, to narrow search for reliable values of quantitative control parameters.

  6. Experimental light scattering by small particles: first results with a novel Mueller matrix scatterometer

    NASA Astrophysics Data System (ADS)

    Penttilä, Antti; Maconi, Göran; Kassamakov, Ivan; Gritsevich, Maria; Helander, Petteri; Puranen, Tuomas; Hæggström, Edward; Muinonen, Karri

    2017-06-01

    We describe a setup for measuring the full angular Mueller matrix profile of a single mm- to μm-sized sample, and verify the experimental results against a theoretical model. The scatterometer has a fixed or levitating sample, illuminated with a laser beam whose full polarization state is controlled. The scattered light is detected with a combination of wave retarder, linear polarizer, and photomultiplier tube that is attached to a rotational stage. The first results are reported.

  7. β-trace protein as a diagnostic marker for perilymphatic fluid fistula: a prospective controlled pilot study to test a sample collection technique.

    PubMed

    Bachmann-Harildstad, Gregor; Stenklev, Niels Christian; Myrvoll, Elin; Jablonski, Greg; Klingenberg, Olav

    2011-01-01

    The diagnosis of perilymphatic fluid (PLF) fistula is still challenging. Perilymphatic fluid fistula is one possible complication after stapedotomy or cochlear implant surgery. We have performed a prospective diagnostic pilot study to further investigate β-trace protein (β-TP) as a marker for PLF fistula. In this pilot study, we tested the sensitivity of the β-TP marker using a simple method for sample collection from the tympanic cavity. Prospective controlled diagnostic study. Two-center tertiary referral hospitals. A total of 35 adult patients undergoing ear surgery were included. Subjects were divided into 2 groups: 1) 19 patients undergoing stapedotomy were investigated for PLF fistula in samples obtained from the tympanic cavity and 2) 16 patients undergoing myringoplasty were investigated for PLF fistula in samples from the tympanic cavity. This group served as the control. Mean age +/- SD at surgery was 49.9 +/- 8.0 years in the study group and 39.69 +/- 15.47 years in the control group. β-Trace protein (prostaglandin D synthase) in tympanic cavity samples and serum samples was analyzed. The samples were collected by gradually filling the tympanic cavity with 100 to 200 μl sodium chloride and by immediately collecting a volume of 60 to 100 μl in a mucus specimen set container. The concentration of β-TP was quantified using laser nephelometry. The median β-TP in the study group was 0.8 mg/L (range, 0.05-4.5 mg/L). In the control group, the median β-TP value was 0.16 mg/L (range, 0.01-0.36 mg/L). Thirty-five percent of the values in the study group were below the highest value in the negative control group. The β-TP values of the tympanic cavity samples were significantly higher in the study group than in controls (p = 0.0001). The serum values were 0.55 +/- 0.18 and 0.53 +/- 0.11 mg/L, respectively. It may be feasible to test for PLF fistula using β-TP in samples from the tympanic cavity. Our results, however, suggest a relative low diagnostic sensitivity, given a cutoff that is set to obtain a high specificity when using a simple sample collection method. Furthermore, the test does not permit the distinction between PLF fistula and cerebrospinal fluid fistula. Further studies should focus on minimal dilution at sampling and on minimizing sample volumes.

  8. Influence of respiratory tract disease and mode of inhalation on detectability of budesonide in equine urine and plasma.

    PubMed

    Barton, Ann Kristin; Heinemann, Henrike; Schenk, Ina; Machnik, Marc; Gehlen, Heidrun

    2017-02-01

    OBJECTIVE To evaluate the influence of respiratory tract disease (ie, recurrent airway obstruction [RAO]) and mode of inhalation on detectability of inhaled budesonide in equine plasma and urine samples. ANIMALS 16 horses (8 healthy control horses and 8 horses affected by RAO, as determined by results of clinical examination, blood gas analysis, bronchoscopy, and cytologic examination of bronchoalveolar lavage fluid). PROCEDURES 4 horses of each group inhaled budesonide (3 μg/kg) twice daily for 10 days while at rest, and the remaining 4 horses of each group inhaled budesonide during lunging exercise. Plasma and urine samples were obtained 4 to 96 hours after inhalation and evaluated for budesonide and, in urine samples, the metabolites 6β-hydroxybudesonide and 16α-hydroxyprednisolone. RESULTS Detected concentrations of budesonide were significantly higher at all time points for RAO-affected horses, compared with concentrations for the control horses. All samples of RAO-affected horses contained budesonide concentrations above the limit of detection at 96 hours after inhalation, whereas this was found for only 2 control horses. Detected concentrations of budesonide were higher, but not significantly so, at all time points in horses that inhaled budesonide during exercise, compared with concentrations for inhalation at rest. CONCLUSIONS AND CLINICAL RELEVANCE Results of this study indicated that the time interval between inhalation of a glucocorticoid and participation in sporting events should be increased when inhalation treatment is administered during exercise to horses affected by respiratory tract disease.

  9. Transport of fluorobenzoate tracers in a vegetated hydrologic control volume: 1. Experimental results

    NASA Astrophysics Data System (ADS)

    Queloz, Pierre; Bertuzzo, Enrico; Carraro, Luca; Botter, Gianluca; Miglietta, Franco; Rao, P. S. C.; Rinaldo, Andrea

    2015-04-01

    This paper reports about the experimental evidence collected on the transport of five fluorobenzoate tracers injected under controlled conditions in a vegetated hydrologic volume, a large lysimeter (fitted with load cells, sampling ports, and an underground chamber) where two willows prompting large evapotranspiration fluxes had been grown. The relevance of the study lies in the direct and indirect measures of the ways in which hydrologic fluxes, in this case, evapotranspiration from the upper surface and discharge from the bottom drainage, sample water and solutes in storage at different times under variable hydrologic forcings. Methods involve the accurate control of hydrologic inputs and outputs and a large number of suitable chemical analyses of water samples in discharge waters. Mass extraction from biomass has also been performed ex post. The results of the 2 year long experiment established that our initial premises on the tracers' behavior, known to be sorption-free under saturated conditions which we verified in column leaching tests, were unsuitable as large differences in mass recovery appeared. Issues on reactivity thus arose and were addressed in the paper, in this case attributed to microbial degradation and solute plant uptake. Our results suggest previously unknown features of fluorobenzoate compounds as hydrologic tracers, potentially interesting for catchment studies owing to their suitability for distinguishable multiple injections, and an outlook on direct experimental closures of mass balance in hydrologic transport volumes involving fluxes that are likely to sample differently stored water and solutes.

  10. Association between oral lichen planus and Epstein-Barr virus in Iranian patients.

    PubMed

    Shariati, Matin; Mokhtari, Mojgan; Masoudifar, Aria

    2018-01-01

    Oral lichen planus (OLP) is a common mucocutaneous disease with malignant transformation potential. Several etiologies such as humoral, autoimmunity, and viral infections might play a role, but still there is no definite etiology for this disease. The aim of this study was to investigate the presence of Epstein-Barr virus (EBV) genome in Iranian patients with OLP as compared to people with normal mucosa. The study was carried out on a case group including 38 tissue specimens of patients with histopathological confirmation of OLP and a control group including 38 samples of healthy mucosa. All samples were examined by nested polymerase chain reaction (PCR) method to determine the DNA of EBV. Twenty-two (57.9%) female samples and 16 (42.1%) male samples with OLP were randomly selected as the case group, and 20 (52.6%) female samples and 18 (47.4%) male samples with healthy mucosa as the control group. There was a statistically significant difference in the percentage of EBV positivity between the case (15.8%) and the control groups ( P < 0.05); in the case group, three female samples (13.6%) and three male samples (18.8%) were infected with EBV; the difference between the genders was not statistically significant ( P = 0.50). Results emphasized that EBV genome was significantly higher among Iranian patients with OLP so antiviral therapy might be helpful.

  11. A mixture model with a reference-based automatic selection of components for disease classification from protein and/or gene expression levels

    PubMed Central

    2011-01-01

    Background Bioinformatics data analysis is often using linear mixture model representing samples as additive mixture of components. Properly constrained blind matrix factorization methods extract those components using mixture samples only. However, automatic selection of extracted components to be retained for classification analysis remains an open issue. Results The method proposed here is applied to well-studied protein and genomic datasets of ovarian, prostate and colon cancers to extract components for disease prediction. It achieves average sensitivities of: 96.2 (sd = 2.7%), 97.6% (sd = 2.8%) and 90.8% (sd = 5.5%) and average specificities of: 93.6% (sd = 4.1%), 99% (sd = 2.2%) and 79.4% (sd = 9.8%) in 100 independent two-fold cross-validations. Conclusions We propose an additive mixture model of a sample for feature extraction using, in principle, sparseness constrained factorization on a sample-by-sample basis. As opposed to that, existing methods factorize complete dataset simultaneously. The sample model is composed of a reference sample representing control and/or case (disease) groups and a test sample. Each sample is decomposed into two or more components that are selected automatically (without using label information) as control specific, case specific and not differentially expressed (neutral). The number of components is determined by cross-validation. Automatic assignment of features (m/z ratios or genes) to particular component is based on thresholds estimated from each sample directly. Due to the locality of decomposition, the strength of the expression of each feature across the samples can vary. Yet, they will still be allocated to the related disease and/or control specific component. Since label information is not used in the selection process, case and control specific components can be used for classification. That is not the case with standard factorization methods. Moreover, the component selected by proposed method as disease specific can be interpreted as a sub-mode and retained for further analysis to identify potential biomarkers. As opposed to standard matrix factorization methods this can be achieved on a sample (experiment)-by-sample basis. Postulating one or more components with indifferent features enables their removal from disease and control specific components on a sample-by-sample basis. This yields selected components with reduced complexity and generally, it increases prediction accuracy. PMID:22208882

  12. [Comparative analysis of malaria detection ability of laboratories in Shanghai City from 2012 to 2015].

    PubMed

    Zhen-Yu, Wang; Li, Jiang; Yao-Guang, Zhang; Min, Zhu; Xiao-Ping, Zhang; Xiao-Jiang, Ma; Qian, Zhu; Yan-Yan, He; Shou-Fu, Jiang; Li, Cai

    2017-02-27

    To compare the application effects of three methods, namely microscopic examination, antigen detection (RDT) and nucleic acid test (PCR) in malaria detection between municipal and districts/counties centers for disease control and prevention in Shanghai, and analyze the malaria detection ability of the laboratories in Shanghai. The blood smears, whole blood samples, case review confirmation records and case data of malaria cases and suspected cases in Shanghai from 2012 to 2015 were collected by Shanghai Municipal Center for Disease Control and Prevention, and the detection results were analyzed and compared. A total of 212 samples with complete data were submitted by all districts (counties) in Shanghai from 2012 to 2015, the samples submitted by Jinshan Districts were the most (41.98%), and among the first diagnosis hospitals, those submitted by the tertiary hospitals were the most (82.07%). The submitted samples in the whole year were increased gradually from January to October. All the 212 samples were detected by three methods (the microscopic examination, RDT and PCR) in the laboratory of Shanghai Municipal Center for Disease Control and Prevention, and 167 were tested and confirmed comprehensively as positives, accounting for 78.77%, and 45 were confirmed as negatives, accounting for 21.23%. The samples were detected by the method of microscopy and domestic RDT in the laboratories of the centers for disease control and prevention at district/county level, totally 153 were tested as positives, accounting for 72.17%, 41 were unclassified, accounting for 19.34%, 53 were negative, accounting for 25.00%, and 6 were undetected, accounting for 2.83%. The coincidence of microscopic examination between the report hospitals and the centers for disease control and prevention at district/county level was 78.16%, and the coincidence between centers for disease control and prevention at district/county level and municipal level was 93.20%. The utilization rate of RDT in the laboratory of district/county level was 73.58%. The coincidence of RDT tests between those domestic and imported was 93.59%. Compared with the detection results by municipal center for disease control and prevention, 37 samples were misjudged by the laboratories of district/county level. Almost all (99.37%) of the confirmed malaria cases were imported overseas, including Africa (85.44%), Asia (13.92%) and America (0.63%). The surveillance after malaria elimination in Shanghai should be carried out by combining with different detection methods and resource integration.

  13. External and semi-internal controls for PCR amplification of homologous sequences in mixed templates.

    PubMed

    Kalle, Elena; Gulevich, Alexander; Rensing, Christopher

    2013-11-01

    In a mixed template, the presence of homologous target DNA sequences creates environments that almost inevitably give rise to artifacts and biases during PCR. Heteroduplexes, chimeras, and skewed template-to-product ratios are the exclusive attributes of mixed template PCR and never occur in a single template assay. Yet, multi-template PCR has been used without appropriate attention to quality control and assay validation, in spite of the fact that such practice diminishes the reliability of results. External and internal amplification controls became obligatory elements of good laboratory practice in different PCR assays. We propose the inclusion of an analogous approach as a quality control system for multi-template PCR applications. The amplification controls must take into account the characteristics of multi-template PCR and be able to effectively monitor particular assay performance. This study demonstrated the efficiency of a model mixed template as an adequate external amplification control for a particular PCR application. The conditions of multi-template PCR do not allow implementation of a classic internal control; therefore we developed a convenient semi-internal control as an acceptable alternative. In order to evaluate the effects of inhibitors, a model multi-template mix was amplified in a mixture with DNAse-treated sample. Semi-internal control allowed establishment of intervals for robust PCR performance for different samples, thus enabling correct comparison of the samples. The complexity of the external and semi-internal amplification controls must be comparable with the assumed complexity of the samples. We also emphasize that amplification controls should be applied in multi-template PCR regardless of the post-assay method used to analyze products. © 2013 Elsevier B.V. All rights reserved.

  14. Using Length of Stay to Control for Unobserved Heterogeneity When Estimating Treatment Effect on Hospital Costs with Observational Data: Issues of Reliability, Robustness, and Usefulness.

    PubMed

    May, Peter; Garrido, Melissa M; Cassel, J Brian; Morrison, R Sean; Normand, Charles

    2016-10-01

    To evaluate the sensitivity of treatment effect estimates when length of stay (LOS) is used to control for unobserved heterogeneity when estimating treatment effect on cost of hospital admission with observational data. We used data from a prospective cohort study on the impact of palliative care consultation teams (PCCTs) on direct cost of hospital care. Adult patients with an advanced cancer diagnosis admitted to five large medical and cancer centers in the United States between 2007 and 2011 were eligible for this study. Costs were modeled using generalized linear models with a gamma distribution and a log link. We compared variability in estimates of PCCT impact on hospitalization costs when LOS was used as a covariate, as a sample parameter, and as an outcome denominator. We used propensity scores to account for patient characteristics associated with both PCCT use and total direct hospitalization costs. We analyzed data from hospital cost databases, medical records, and questionnaires. Our propensity score weighted sample included 969 patients who were discharged alive. In analyses of hospitalization costs, treatment effect estimates are highly sensitive to methods that control for LOS, complicating interpretation. Both the magnitude and significance of results varied widely with the method of controlling for LOS. When we incorporated intervention timing into our analyses, results were robust to LOS-controls. Treatment effect estimates using LOS-controls are not only suboptimal in terms of reliability (given concerns over endogeneity and bias) and usefulness (given the need to validate the cost-effectiveness of an intervention using overall resource use for a sample defined at baseline) but also in terms of robustness (results depend on the approach taken, and there is little evidence to guide this choice). To derive results that minimize endogeneity concerns and maximize external validity, investigators should match and analyze treatment and comparison arms on baseline factors only. Incorporating intervention timing may deliver results that are more reliable, more robust, and more useful than those derived using LOS-controls. © Health Research and Educational Trust.

  15. Religious orientation, low self-control, and deviance: Muslims, Catholics, Eastern Orthodox-, and "Bible Belt" Christians.

    PubMed

    Klanjšek, Rudi; Vazsonyi, Alexander T; Trejos-Castillo, Elizabeth

    2012-06-01

    Using adolescent samples from four cultures, the current study tested whether effects by religiosity on deviance varied by the nature of religiosity (intrinsic versus extrinsic) and by the cultural context (Bosnia & Herzegovina, Serbia, Slovenia, and the U.S.). Results indicated: a) that not every type of religiosity has a buffering effect on deviance - if one's religiousness is predominately instrumental (i.e. extrinsic), then its inhibiting effect is weak or does not exist; b) that the effect of intrinsic religiosity seemed more pronounced in the two surroundings that expressed the highest mean religiosity (U.S., Bosnia & Herzegovina) although results from follow-up analysis (Z-tests) largely supported a cultural invariance hypothesis. In addition, the intrinsic religiosity-deviance link was moderated by low self-control in each sample, except the Slovenian one. Finally, results indicated that low self-control only partially mediated the religiosity-deviance link. Copyright © 2011 The Foundation for Professionals in Services for Adolescents. Published by Elsevier Ltd. All rights reserved.

  16. Controlled motion of domain walls in submicron amorphous wires

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ţibu, Mihai; Lostun, Mihaela; Rotărescu, Cristian

    Results on the control of the domain wall displacement in cylindrical Fe{sub 77.5}Si{sub 7.5}B{sub 15} amorphous glass-coated submicron wires prepared by rapid quenching from the melt are reported. The control methods have relied on conical notches with various depths, up to a few tens of nm, made in the glass coating and in the metallic nucleus using a focused ion beam (FIB) system, and on the use of small nucleation coils at one of the sample ends in order to apply magnetic field pulses aimed to enhance the nucleation of reverse domains. The notch-based method is used for the firstmore » time in the case of cylindrical ultrathin wires. The results show that the most efficient technique of controlling the domain wall motion in this type of samples is the simultaneous use of notches and nucleation coils. Their effect depends on wire diameter, notch depth, its position on the wire length, and characteristics of the applied pulse.« less

  17. Browning control of fresh-cut lettuce by phytoncide treatment.

    PubMed

    Kim, Do-Hee; Kim, Han-Bit; Chung, Hun-Sik; Moon, Kwang-Deog

    2014-09-15

    Phytoncide essential oil derived from pine leaves was applied for the control of enzymatic browning of fresh-cut lettuce. Changes in the browning characteristics of cut lettuce treated with phytoncide in an water or ethanol solution (1%, v/v) at 10°C were investigated for 12days at 4°C. Other samples dipped in distilled water or 95% ethanol were used as the controls. The samples treated with phytoncide in an ethanol solution showed significantly higher L* values and lower a* values, ΔE values, browning index, phenolic compounds, and enzyme activities (PPO, POD, PAL) related to browning. The samples dipped in distilled water showed the opposite tendency. On the basis of changes in the browning characteristics, anti-browning effects of each treatment, phytoncide in an ethanol solution was the most effective treatment applied. These results suggest that phytoncide treatment could be used as an effective method for controlling enzymatic browning in fresh-cut lettuce. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Individualism and collectivism: cultural orientation in locus of control and moral attribution under conditions of social change.

    PubMed

    Santiago, Jose H; Tarantino, Santo J

    2002-12-01

    This study examined the validity of the view that the constructs of individualism and collectivism are coherent cultural manifestations necessarily reflected in an individual's attribution patterns. It was hypothesized that the attribution patterns of locus of control and moral accountability would show divergent individualistic and collectivistic influences in a culture during change from a collectivist culture to an individualist culture. 98 university students from the United States and Puerto Rico were administered the Singelis Individualism-Collectivism Scale, Rotter's Locus of Control Scale, and Miller and Luthar's justice-related moral accountability vignettes. Contrary to expectation, the Puerto Rican sample scored less external in locus of control than the United States sample. No cultural differences in moral accountability were found. No strong correlations were found among the variables at the individual level of analysis. Accounting for these results included the lack of representativeness of the samples, the independence of relation between variables at different levels of analysis, and social change.

  19. Reducing diarrhea through the use of household-based ceramic water filters: a randomized, controlled trial in rural Bolivia.

    PubMed

    Clasen, Thomas F; Brown, Joseph; Collin, Simon; Suntura, Oscar; Cairncross, Sandy

    2004-06-01

    Ceramic water filters have been identified as one of the most promising and accessible technologies for treating water at the household level. In a six-month trial, water filters were distributed randomly to half of the 50 participating households in a rural community in Bolivia; the remaining households continued to use customary water handling practices and served as controls. In four rounds of sampling following distribution of the filters, 100% of the 96 water samples from the filter households were free of thermotolerant coliforms compared with 15.5% of the control household samples. Diarrheal disease risk for individuals in intervention households was 70% lower than for controls (95% confidence interval [CI] = 53-80%; P < 0.001). For children less than five years old, the reduction in risk was 83% (95% CI = 51-94%; P < 0.001). These results show that affordable ceramic water filters enable low-income households to treat and maintain the microbiologic quality of their drinking water.

  20. Quality and sensory acceptability of a chilled functional apple ready-dessert.

    PubMed

    Keenan, D F; Brunton, N P; Gormley, T R; Butler, F

    2012-04-01

    An apple and dairy based ready-dessert with an added prebiotic was stored and chill temperatures and number of quality attributes were monitored during chill (4 °C) storage for 30 days. All ready-desserts were thermally processed by sous vide (P (90) > 10 min). The stability of the dairy component in ready-desserts was monitored by measuring volatile free fatty acids. Changes in these components were more evident in prebiotic-enriched samples compared to controls. However, no significant differences were observed over storage in control and prebiotic-enriched ready-desserts. This was supported by sensory analysis that showed no significant changes over storage in control or prebiotic-enriched samples. Of the other quality parameters, the addition of prebiotic inclusions resulted in lower L and b values and dry matter (p < 0.05), while increasing (p < 0.05) soluble solids content compared to control samples. Fluctuations in some of the quality parameters were also observed over storage. Rheological characteristics, i.e. flow behaviour (n), consistency index (K), storage (G'), loss (G″) and complex (G*) moduli were unaffected by prebiotic inclusion. However, storage affected the rheological characteristics of ready-desserts. A decrease (p < 0.05) in flow behaviour (n) led to concomitant increases in consistency index (K) and complex modulus (G*) values in control samples.

  1. A Novel Glass Polyalkenoate Cement for Fixation and Stabilisation of the Ribcage, Post Sternotomy Surgery: An ex-Vivo Study

    PubMed Central

    Alhalawani, Adel M.F.; Curran, Declan J.; Pingguan-Murphy, Belinda; Boyd, Daniel; Towler, Mark R.

    2013-01-01

    This study investigates the use of gallium (Ga) based glass polyalkenoate cements (GPCs) as a possible alternative adhesive in sternal fixation, post sternotomy surgery. The glass series consists of a Control (CaO–ZnO–SiO2), and LGa-1 and LGa-2 which contain Ga at the expense of zinc (Zn) in 0.08 mol% increments. The additions of Ga resulted in increased working time (75 s to 137 s) and setting time (113 to 254 s). Fourier Transform Infrared (FTIR) analysis indicated that this was a direct result of increased unreacted poly(acrylic acid) (PAA) and the reduction of crosslink formation during cement maturation. LGa samples (0.16 wt % Ga) resulted in an altered ion release profile, particularly for 30 days analysis, with maximum Ca2+, Zn2+, Si4+ and Ga3+ ions released into the distilled water. The additions of Ga resulted in increased roughness and decreased contact angles during cement maturation. The presence of Ga has a positive effect on the compressive strength of the samples with strengths increasing over 10 MPa at 7 days analysis compared to the 1 day results. The additions of Ga had relatively no effect on the flexural strength. Tensile testing of bovine sterna proved that the LGa samples (0.16 wt % Ga) are comparable to the Control samples. PMID:24956193

  2. Assessment of arsenic exposures and controls in gallium arsenide production.

    PubMed

    Sheehy, J W; Jones, J H

    1993-02-01

    The electronics industry is expanding the use of gallium arsenide in the production of optoelectronic devices and integrated circuits. Workers in the electronics industry using gallium arsenide are exposed to hazardous substances such as arsenic, arsine, and various acids. Arsenic requires stringent controls to minimize exposures (the current OSHA PEL for arsenic is 10 micrograms/m3 and the NIOSH REL is 2 micrograms/m3 ceiling). Inorganic arsenic is strongly implicated in respiratory tract and skin cancer. For these reasons, NIOSH researchers conducted a study of control systems for facilities using gallium arsenide. Seven walk-through surveys were performed to identify locations for detailed study which appeared to have effective controls; three facilities were chosen for in-depth evaluation. The controls were evaluated by industrial hygiene sampling. Including personal breathing zone and area air sampling for arsenic and arsine; wipe samples for arsenic also were collected. Work practices and the use of personal protective equipment were documented. This paper reports on the controls and the arsenic exposure results from the evaluation of the following gallium arsenide processes: Liquid Encapsulated Czochralski (LEC) and Horizontal Bridgeman (HB) crystal growing, LEC cleaning operations, ingot grinding/wafer sawing, and epitaxy. Results at one plant showed that in all processes except epitaxy, average arsenic exposures were at or above the OSHA action level of 5 micrograms/m3. While cleaning the LEC crystal pullers, the average potential arsenic exposure of the cleaning operators was 100 times the OSHA PEL. At the other two plants, personal exposures for arsenic were well controlled in LEC, LEC cleaning, grinding/sawing, and epitaxy operations.

  3. Frequencies of neuronal autoantibodies in healthy controls

    PubMed Central

    Lang, Katharina

    2017-01-01

    Objective: To provide an extensive overview on the prevalence of antibodies against neuronal surfaces (neuronal surface antibody [NSAb]) in healthy participants and disease controls. Methods: We searched the PubMed database (1974 to October 2016) for studies that analyzed frequencies of 22 different NSAbs in serum or CSF and included controls. Antibody prevalence was calculated for patients with NSAb-mediated disease and controls, including healthy participants, and those with neurologic and nonneurologic diseases. Different assays for antibody detection were compared. Results: In 309 articles, 743,299 antibody tests for 22 NSAbs were performed, including 30,485 tests for 19 NSAbs in healthy controls (HCs). Of these, 26,423 (86.7%) were tested with current standard methods, usually cell-based assays. Prevalence was very low in HCs (mean 0.23%, absent for 9/19 antibodies), and test numbers ranged from 21 to 3,065 per antibody. One study reported >1,000 healthy participants, and the others contained 21–274 samples. CSF samples were virtually not available from HCs. NSAb prevalence was considerably higher (1.5%) in 69,850 disease controls, i.e., patients not initially suspected to have NSAb-mediated diseases. Antibody determination in controls using nonstandard assays (such as ELISA) resulted in 6% positivity. Conclusions: NSAbs are rarely found in healthy participants, particularly with standard detection methods, suggesting high disease specificity and supporting their diagnostic usefulness. Conversely, positive titers in atypical patients might point to the still expanding phenotypic spectrum. Future studies should include more CSF samples, data from HCs, and experimental evidence for antibody pathogenicity. PMID:28761905

  4. Research on width control of Metal Fused-coating Additive Manufacturing based on active control

    NASA Astrophysics Data System (ADS)

    Ren, Chuan qi; Wei, Zheng ying; Wang, Xin; Du, Jun; Zhang, Shan; Zhang, Zhitong; Bai, Hao

    2017-12-01

    Given the stability of the shape of the forming layer is one of the key problems that affect the final quality of the sample morphology, taking a study on the forming process and the control method of morphology make a significant difference to metal fused-coating additive manufacturing (MFCAM) in achieving the efficient and stable forming. To improve the quality and precision of the samples of single-layer single pass, a control method of morphology based on active control was established by this paper. The real-time acquisition of image was realized by CCD and the characteristics of morphology of the forming process were simultaneously extracted. Making analysis of the characteristics of the width during the process, the relationship between the relative difference of different frames and moving speed was given. A large number of experiments are used to verify the response speed and accuracy of the system. The results show that the active system can improve the morphology of the sample and the smoothness of the width of the single channel, and increase the uniformity of width by 55.16%.

  5. Infrared Spectroscopy of Blood for Disease Identification

    NASA Astrophysics Data System (ADS)

    Pichardo, J. L.; Huerta-Franco, R.; Álvarez, R. R.; Bernal, J.; Gutiérrez-Juárez, G.; Palomares-Anda, P.

    2003-09-01

    Total reflectance attenuated infrared Fourier transform spectroscopy was used to analyze blood samples. Plasma and red blood cells were separated by centrifugation. The spectra were recorded from 200 to 4000 cm-1 under the same conditions for all samples. Samples of healthy donors were compared with those patients with different diseases (polycythemia and high blood pressure). Patients were under medical control at the time of the study. However, the preliminary results reveal that blood samples from healthy subjects had different infrared spectra compared to the non healthy patients.

  6. Gender, Race, and Delinquent Behavior: An Extension of Power-Control Theory to American Indian Adolescents

    PubMed Central

    Eitle, David; Niedrist, Fallon; Eitle, Tamela McNulty

    2014-01-01

    Research testing Hagan’s power-control theory has largely been tested with samples of non-Hispanic whites. We extend prior research by testing the theory’s merits with a sample of American Indian (AI) adolescents. Overall, we find mixed support for the theory’s merits. However, we find that our measure of patriarchy is a robust predictor of AI female delinquent activity. We also find that a grandparent in the household serves to greatly reduce involvement in violent behavior among AI females. Compared to a sample of non-Hispanic whites, these results reveal the importance of testing explanations of deviant behavior across racial and ethnic groups. PMID:25342866

  7. Practical limits on muscle synergy identification by non-negative matrix factorization in systems with mechanical constraints.

    PubMed

    Burkholder, Thomas J; van Antwerp, Keith W

    2013-02-01

    Statistical decomposition, including non-negative matrix factorization (NMF), is a convenient tool for identifying patterns of structured variability within behavioral motor programs, but it is unclear how the resolved factors relate to actual neural structures. Factors can be extracted from a uniformly sampled, low-dimension command space. In practical application, the command space is limited, either to those activations that perform some task(s) successfully or to activations induced in response to specific perturbations. NMF was applied to muscle activation patterns synthesized from low dimensional, synergy-like control modules mimicking simple task performance or feedback activation from proprioceptive signals. In the task-constrained paradigm, the accuracy of control module recovery was highly dependent on the sampled volume of control space, such that sampling even 50% of control space produced a substantial degradation in factor accuracy. In the feedback paradigm, NMF was not capable of extracting more than four control modules, even in a mechanical model with seven internal degrees of freedom. Reduced access to the low-dimensional control space imposed by physical constraints may result in substantial distortion of an existing low dimensional controller, such that neither the dimensionality nor the composition of the recovered/extracted factors match the original controller.

  8. The ice nucleation temperature determines the primary drying rate of lyophilization for samples frozen on a temperature-controlled shelf.

    PubMed

    Searles, J A; Carpenter, J F; Randolph, T W

    2001-07-01

    The objective of this study was to determine the influence of ice nucleation temperature on the primary drying rate during lyophilization for samples in vials that were frozen on a lyophilizer shelf. Aqueous solutions of 10% (w/v) hydroxyethyl starch were frozen in vials with externally mounted thermocouples and then partially lyophilized to determine the primary drying rate. Low- and high-particulate-containing samples, ice-nucleating additives silver iodide and Pseudomonas syringae, and other methods were used to obtain a wide range of nucleation temperatures. In cases where the supercooling exceeded 5 degrees C, freezing took place in the following three steps: (1) primary nucleation, (2) secondary nucleation encompassing the entire liquid volume, and (3) final solidification. The primary drying rate was dependent on the ice nucleation temperature, which is stochastic in nature but is affected by particulate content and the presence of ice nucleators. Sample cooling rates of 0.05 to 1 degrees C/min had no effect on nucleation temperatures and drying rate. We found that the ice nucleation temperature is the primary determinant of the primary drying rate. However, the nucleation temperature is not under direct control, and its stochastic nature and sensitivity to difficult-to-control parameters result in drying rate heterogeneity. Nucleation temperature heterogeneity may also result in variation in other morphology-related parameters such as surface area and secondary drying rate. Overall, these results document that factors such as particulate content and vial condition, which influence ice nucleation temperature, must be carefully controlled to avoid, for example, lot-to-lot variability during cGMP production. In addition, if these factors are not controlled and/or are inadvertently changed during process development and scaleup, a lyophilization cycle that was successful on the research scale may fail during large-scale production.

  9. [Purifying process of gynostemma pentaphyllum saponins based on "adjoint marker" online control technology and identification of their compositions by UPLC-QTOF-MS].

    PubMed

    Fan, Dong-Dong; Kuang, Yan-Hui; Dong, Li-Hua; Ye, Xiao; Chen, Liang-Mian; Zhang, Dong; Ma, Zhen-Shan; Wang, Jin-Yu; Zhu, Jing-Jing; Wang, Zhi-Min; Wang, De-Qin; Li, Chu-Yuan

    2017-04-01

    To optimize the purification process of gynostemma pentaphyllum saponins (GPS) based on "adjoint marker" online control technology with GPS as the testing index. UPLC-QTOF-MS technology was used for qualitative analysis. "Adjoint marker" online control results showed that the end point of load sample was that the UV absorbance of effluent liquid was equal to half of that of load sample solution, and the absorbance was basically stable when the end point was stable. In UPLC-QTOF-MS qualitative analysis, 16 saponins were identified from GPS, including 13 known gynostemma saponins and 3 new saponins. This optimized method was proved to be simple, scientific, reasonable, easy for online determination, real-time record, and can be better applied to the mass production and automation of production. The results of qualitative analysis indicated that the "adjoint marker" online control technology can well retain main efficacy components of medicinal materials, and provide analysis tools for the process control and quality traceability. Copyright© by the Chinese Pharmaceutical Association.

  10. Leadership Challenges in ISS Operations: Lessons Learned from Junior and Senior Mission Control Personnel

    NASA Technical Reports Server (NTRS)

    Clement, James L.; Ritsher, Jennifer Boyd; Saylor, Stephanie A.; Kanas, Nick

    2006-01-01

    The International Space Station (ISS) is operated by a multi-national, multi-organizational team that is dispersed across multiple locations, time zones, and work schedules. At NASA, both junior and senior mission control personnel have had to find ways to address the leadership challenges inherent in such work, but neither have had systematic training in how to do so. The goals of this study were to examine the major leadership challenges faced by ISS mission control personnel and to highlight the approaches that they have found most effective to surmount them. We pay particular attention to the approaches successfully employed by the senior personnel and to the training needs identified by the junior personnel. We also evaluate the extent to which responses are consistent across the junior and senior samples. Further, we compare the issues identified by our interview survey to those identified by a standardized questionnaire survey of mission control personnel and a contrasting group of space station crewmembers. We studied a sample of 14 senior ISS flight controllers and a contrasting sample of 12 more junior ISS controllers. Data were collected using a semi-structured qualitative interview and content analyzed using an iterative process with multiple coders and consensus meetings to resolve discrepancies. To further explore the meaning of the interview findings, we also conducted new analyses of data from a previous questionnaire study of 13 American astronauts, 17 Russian cosmonauts, and 150 U.S. and 36 Russian mission control personnel supporting the ISS or Mir space stations. The interview data showed that the survey respondents had substantial consensus on several leadership challenges and on key strategies for dealing with them, and they offered a wide range of specific tactics for implementing these strategies. Interview data from the junior respondents will be presented for the first time at the meeting. The questionnaire data showed that the US mission control sample reported a level of support from their management that compared favorably to national norms. American mission control personnel and Russian crewmembers reported higher supervisor support than American crewmembers and Russian mission control personnel. We will present the specific issues underlying these findings and compare and contrast the results from the two datasets. Although specific to space station personnel, our results are consistent with recent management, cultural, and aerospace research. We aim to use our results to improve training for current and future mission control personnel.

  11. Investigation of wear land and rate of locally made HSS cutting tool

    NASA Astrophysics Data System (ADS)

    Afolalu, S. A.; Abioye, A. A.; Dirisu, J. O.; Okokpujie, I. P.; Ajayi, O. O.; Adetunji, O. R.

    2018-04-01

    Production technology and machining are inseparable with cutting operation playing important roles. Investigation of wear land and rate of cutting tool developed locally (C=0.56%) with an HSS cutting tool (C=0.65%) as a control was carried out. Wear rate test was carried out using Rotopol -V and Impact tester. The samples (12) of locally made cutting tools and one (1) sample of a control HSS cutting tool were weighed to get the initial weight and grit was fixed at a point for the sample to revolve at a specific time of 10 mins interval. Approach of macro transfer particles that involved mechanism of abrasion and adhesion which was termed as mechanical wear to handle abrasion adhesion processes was used in developing equation for growth wear at flank. It was observed from the wear test that best minimum wear rate of 1.09 × 10-8 and 2.053 × 10-8 for the tools developed and control were measured. MATLAB was used to simulate the wear land and rate under different conditions. Validated results of both the experimental and modeling showed that cutting speed has effect on wear rate while cutting time has predicted measure on wear land. Both experimental and modeling result showed best performances of tools developed over the control.

  12. Scheduling whole-air samples above the Trade Wind Inversion from SUAS using real-time sensors

    NASA Astrophysics Data System (ADS)

    Freer, J. E.; Greatwood, C.; Thomas, R.; Richardson, T.; Brownlow, R.; Lowry, D.; MacKenzie, A. R.; Nisbet, E. G.

    2015-12-01

    Small Unmanned Air Systems (SUAS) are increasingly being used in science applications for a range of applications. Here we explore their use to schedule the sampling of air masses up to 2.5km above ground using computer controlled bespoked Octocopter platforms. Whole-air sampling is targeted above, within and below the Trade Wind Inversion (TWI). On-board sensors profiled the TWI characteristics in real time on ascent and, hence, guided the altitudes at which samples were taken on descent. The science driver for this research is investigation of the Southern Methane Anomaly and, more broadly, the hemispheric-scale transport of long-lived atmospheric tracers in the remote troposphere. Here we focus on the practical application of SUAS for this purpose. Highlighting the need for mission planning, computer control, onboard sensors and logistics in deploying such technologies for out of line-of-sight applications. We show how such a platform can be deployed successfully, resulting in some 60 sampling flights within a 10 day period. Challenges remain regarding the deployment of such platforms routinely and cost-effectively, particularly regarding training and support. We present some initial results from the methane sampling and its implication for exploring and understanding the Southern Methane Anomaly.

  13. Social cognition in schizophrenia: factor structure, clinical and functional correlates.

    PubMed

    Buck, Benjamin E; Healey, Kristin M; Gagen, Emily C; Roberts, David L; Penn, David L

    2016-08-01

    Social cognition is consistently impaired in people with schizophrenia, separable from general neurocognition, predictive of real-world functioning and amenable to psychosocial treatment. Few studies have empirically examined its underlying factor structure. This study (1) examines the factor structure of social cognition in both a sample of individuals with schizophrenia-spectrum disorders and non-clinical controls and (2) explores relationships of factors to neurocognition, symptoms and functioning. A factor analysis was conducted on social cognition measures in a sample of 65 individuals with schizophrenia or schizoaffective disorder, and 50 control participants. The resulting factors were examined for their relationships to symptoms and functioning. Results suggested a two-factor structure in the schizophrenia sample (social cognition skill and hostile attributional style) and a three-factor structure in the non-clinical sample (hostile attributional style, higher-level inferential processing and lower-level cue detection). In the schizophrenia sample, the social cognition skill factor was significantly related to negative symptoms and social functioning, whereas hostile attributional style predicted positive and general psychopathology symptoms. The factor structure of social cognition in schizophrenia separates hostile attributional style and social cognition skill, and each show differential relationships to relevant clinical variables in schizophrenia.

  14. Detection of the diuretic hydrochlorothiazide in a doping control urine sample as the result of a non-steroidal anti-inflammatory drug (NSAID) tablet contamination.

    PubMed

    Helmlin, Hans-Jörg; Mürner, André; Steiner, Samuel; Kamber, Matthias; Weber, Christina; Geyer, Hans; Guddat, Sven; Schänzer, Wilhelm; Thevis, Mario

    2016-10-01

    Hydrochlorothiazide (HCTZ, 6-chloro-3,4-dihydro-2H-1,2,4-benzothiadiazine-7-sulfonamide-1,1-dioxide) belongs to the class of diuretic agents that represent one of today's cornerstones of the treatment of hypertensive patients. In addition to its clinical relevance, HCTZ is prohibited in sports according to the regulations of the World Anti-Doping Agency (WADA) at all times and has frequently been detected in sports drug testing urine samples worldwide since its ban was introduced in 1988. Despite these facts, the adverse analytical finding concerning HCTZ in an in-competition routine doping control sample collected in December 2014 was further investigated, particularly motivated by the comparably low urinary concentration of the drug accounting for approximately 5ng/mL. The athlete in question did not declare the use of any nutritional supplement or medication other than the ingestion of a non-steroidal anti-inflammatory drug (NSAID) prior to competition. Hence, the drug (formulated as coated tablet) provided by the athlete as well as the corresponding retention sample of the manufacturer were analyzed. Noteworthy, both samples confirmed the presence of about 2μg of HCTZ per tablet. In order to further probe for the plausibility of the observed urinary HCTZ concentrations with the scenario of drug ingestion and subsequent doping control sample collection, administration studies with produced HCTZ-spiked placebo-tablets (2.5μg of HCTZ/tablet) were conducted. Urine specimens were collected prior to and after ingestion of the drug and subjected to routine doping control analytical procedures employing liquid chromatography/tandem mass spectrometry. While blank urine samples returned negative test results, post-administration specimens were found to contain HCTZ at concentrations of approximately 1-16ng/mL, which supported the athlete's inadvertent intake of HCTZ via contaminated NSAID tablets. Due to the substantial sensitivity of test methods employed today by doping control laboratories, even drug contaminations ranging within the good manufacturing practice (GMP) limit of 10ppm overall carry-over can evidently lead to adverse analytical findings. This calls into question whether selected (classes of) substances such as diuretics should be reported only when exceeding a defined reporting level and/or whether adverse analytical findings of non-threshold substances should be reported with an estimated semi-quantitative concentration of the identified substance to facilitate the result management by anti-doping organizations. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. [Optimization of blood gas analysis in intensive care units : Reduction of preanalytical errors and improvement of workflow].

    PubMed

    Kieninger, M; Zech, N; Mulzer, Y; Bele, S; Seemann, M; Künzig, H; Schneiker, A; Gruber, M

    2015-05-01

    Point of care testing with blood gas analysis (BGA) is an important factor for intensive care medicine. Continuous efforts to optimize workflow, improve safety for the staff and avoid preanalytical mistakes are important and should reflect quality management standards. In a prospective observational study it was investigated whether the implementation of a new system for BGA using labeled syringes and automated processing of the specimens leads to improvements compared to the previously used procedure. In a 4-week test period the time until receiving the final results of the BGA with the standard method used in the clinical routine (control group) was compared to the results in a second 4-week test period using the new labeled syringes and automated processing of the specimens (intervention group). In addition, preanalytical mistakes with both systems were checked during routine daily use. Finally, it was investigated whether a delay of 10 min between taking and analyzing the blood samples alters the results of the BGA. Preanalytical errors were frequently observed in the control group where non-deaerated samples were recorded in 87.3 % but in the intervention group almost all samples (98.9 %) were correctly deaerated. Insufficient homogenization due to omission of manual pivoting was seen in 83.2 % in the control group and in 89.9 % in the intervention group; however, in the intervention group the samples were homogenized automatically during the further analytical process. Although a survey among the staff revealed a high acceptance of the new system and a subjective improvement of workflow, a measurable gain in time after conversion to the new procedure could not be seen. The mean time needed for a complete analysis process until receiving the final results was 244 s in the intervention group and 201 s in the control group. A 10-min delay between taking and analyzing the blood samples led to a significant and clinically relevant elevation of the values for partial pressure of oxygen (pO2) in both groups compared to the results when analyzing the samples immediately (118.4 vs. 148.6 mmHg in the control group and 115.3 vs. 123.7 mmHg in the intervention group). When using standard syringes the partial pressure of carbon dioxide (pCO2) was significantly lower (40.5 vs. 38.3 mmHg) whereas no alterations were seen when using the labeled syringes. The implementation of a new BGA system with labeled syringes and automated processing of the specimens was possible without any difficulties under daily clinical routine conditions in this 10-bed intensive care unit (ICU). A gain of time could not be measured but a reduction in preanalytical errors using the labeled syringes with automated processing was found. Delayed analysis of blood samples can lead to significant changes in pO2 and pCO2 depending on the type of syringe used.

  16. Collection and Characterization of Samples for Establishment of a Serum Repository for Lyme Disease Diagnostic Test Development and Evaluation

    PubMed Central

    Molins, Claudia R.; Sexton, Christopher; Young, John W.; Ashton, Laura V.; Pappert, Ryan; Beard, Charles B.

    2014-01-01

    Serological assays and a two-tiered test algorithm are recommended for laboratory confirmation of Lyme disease. In the United States, the sensitivity of two-tiered testing using commercially available serology-based assays is dependent on the stage of infection and ranges from 30% in the early localized disease stage to near 100% in late-stage disease. Other variables, including subjectivity in reading Western blots, compliance with two-tiered recommendations, use of different first- and second-tier test combinations, and use of different test samples, all contribute to variation in two-tiered test performance. The availability and use of sample sets from well-characterized Lyme disease patients and controls are needed to better assess the performance of existing tests and for development of improved assays. To address this need, the Centers for Disease Control and Prevention and the National Institutes of Health prospectively collected sera from patients at all stages of Lyme disease, as well as healthy donors and patients with look-alike diseases. Patients and healthy controls were recruited using strict inclusion and exclusion criteria. Samples from all included patients were retrospectively characterized by two-tiered testing. The results from two-tiered testing corroborated the need for novel and improved diagnostics, particularly for laboratory diagnosis of earlier stages of infection. Furthermore, the two-tiered results provide a baseline with samples from well-characterized patients that can be used in comparing the sensitivity and specificity of novel diagnostics. Panels of sera and accompanying clinical and laboratory testing results are now available to Lyme disease serological test users and researchers developing novel tests. PMID:25122862

  17. Neurocognitive performance in family-based and case-control studies of schizophrenia.

    PubMed

    Gur, Ruben C; Braff, David L; Calkins, Monica E; Dobie, Dorcas J; Freedman, Robert; Green, Michael F; Greenwood, Tiffany A; Lazzeroni, Laura C; Light, Gregory A; Nuechterlein, Keith H; Olincy, Ann; Radant, Allen D; Seidman, Larry J; Siever, Larry J; Silverman, Jeremy M; Sprock, Joyce; Stone, William S; Sugar, Catherine A; Swerdlow, Neal R; Tsuang, Debby W; Tsuang, Ming T; Turetsky, Bruce I; Gur, Raquel E

    2015-04-01

    Neurocognitive deficits in schizophrenia (SZ) are established and the Consortium on the Genetics of Schizophrenia (COGS) investigated such measures as endophenotypes in family-based (COGS-1) and case-control (COGS-2) studies. By requiring family participation, family-based sampling may result in samples that vary demographically and perform better on neurocognitive measures. The Penn computerized neurocognitive battery (CNB) evaluates accuracy and speed of performance for several domains and was administered across sites in COGS-1 and COGS-2. Most tests were included in both studies. COGS-1 included 328 patients with SZ and 497 healthy comparison subjects (HCS) and COGS-2 included 1195 patients and 1009 HCS. Demographically, COGS-1 participants were younger, more educated, with more educated parents and higher estimated IQ compared to COGS-2 participants. After controlling for demographics, the two samples produced very similar performance profiles compared to their respective controls. As expected, performance was better and with smaller effect sizes compared to controls in COGS-1 relative to COGS-2. Better performance was most pronounced for spatial processing while emotion identification had large effect sizes for both accuracy and speed in both samples. Performance was positively correlated with functioning and negatively with negative and positive symptoms in both samples, but correlations were attenuated in COGS-2, especially with positive symptoms. Patients ascertained through family-based design have more favorable demographics and better performance on some neurocognitive domains. Thus, studies that use case-control ascertainment may tap into populations with more severe forms of illness that are exposed to less favorable factors compared to those ascertained with family-based designs.

  18. Cryopreservation of human spermatozoa. I. Effects of holding procedure and seeding on motility, fertilizability, and acrosome reaction.

    PubMed

    Critser, J K; Huse-Benda, A R; Aaker, D V; Arneson, B W; Ball, G D

    1987-04-01

    Three experiments were conducted to evaluate effects of holding semen at +5.0 degrees C for 30 minutes or -5.0 degrees C for 10 minutes and ice crystal induction (seeding) on frozen-thawed human spermatozoa. In experiment 1, spermatozoa were frozen, and postthaw motility was evaluated immediately (0 hour) and 24 hours later. At both 0 and 24 hours, nonfrozen control samples had higher motility than all other treatment groups. At 0 hour postthaw, motility was higher in samples held at -5.0 degrees C for 10 minutes with no significant effect of seeding. At 24 hours, samples held at -5.0 degrees C for 10 minutes and seeded, but not samples held at -5.0 degrees C and not seeded, had higher motility than samples held at +5.0 degrees C. In experiment 2, semen samples were frozen, and fertilizability was evaluated in a zona-free hamster egg penetration assay. Seeded samples had a higher frequency of sperm penetration than either nonfrozen or nonseeded samples. In experiment 3, nonfrozen controls and frozen treatment groups were evaluated for the frequency of survival and acrosomal integrity. Seeded samples had higher frequencies of survival and loss of acrosomal integrity than nonseeded samples. All frozen-thawed samples had a lower frequency of survival and a higher frequency of loss of acrosomal integrity than nonfrozen controls. Although altered patterns of fertilizability and acrosomal integrity are induced, collectively these data suggest that incorporating a holding temperature of -5.0 degrees C for 10 minutes and seeding may result in a superior protocol for freezing human spermatozoa.

  19. Measurement of Phenolic Environmental Estrogens in Women with Uterine Leiomyoma

    PubMed Central

    Shen, Yang; Xu, Qian; Ren, Mulan; Feng, Xu; Cai, Yunlang; Gao, Yongxing

    2013-01-01

    Objectives To investigate the effect of phenolic environmental estrogens on uterine leiomyoma from the perspective of clinical epidemiology. Methods Urine and blood samples were collected from Han women with uterine leiomyoma and women without uterine leiomyoma, living in Nanjing, China, between September 2011 and February 2013. A total of 156 urine samples and 214 blood samples were collected from the uterine leiomyoma group and 106 urine samples and 126 blood plasma samples from the control group. Bisphenol A (BPA), nonylphenol (NP) and octylphenol (OP) concentrations were determined by solid-phase extraction (SPE) coupled with liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). Results Phenolic environmental estrogens in the uterine leiomyoma and control groups were compared based on: gravida>3 and gravida ≤ 3. In participants with gravida>3, urine OP concentration was significantly (P<0.05) higher in the uterine leiomyoma group than in the control group. In participants with gravida ≤ 3, urine NP concentration was significantly (P<0.05) higher in the uterine leiomyoma group compared to controls. Despite obstetric history, urine BPA mean exposure concentration was significantly (P<0.05) different between uterine leiomyoma group and control group. The urine BPA concentration was not significantly (P>0.05) different between gravida>3 and gravida ≤ 3 patients. There was no significant (P>0.05) difference in plasma concentrations of BPA, OP and NP between the leiomyoma group and control group. Mean exposure concentration and range of distribution of BPA, OP and NP plasma concentration differed between the uterine leiomyoma and control group. Conclusion Exposure level of phenolic environmental estrogens in human was related with leiomyoma tumorigenesis. PMID:24255718

  20. Serum visfatin concentration in acutely ill and weight-recovered patients with anorexia nervosa.

    PubMed

    Seidel, Maria; King, Joseph A; Ritschel, Franziska; Döpmann, Johanna; Bühren, Katharina; Seitz, Jochen; Roessner, Veit; Westphal, Sabine; Egberts, Karin; Burghardt, Roland; Wewetzer, Christoph; Fleischhaker, Christian; Hebebrand, Johannes; Herpertz-Dahlmann, Beate; Ehrlich, Stefan

    2015-03-01

    Visfatin is a recently described protein that is thought to regulate the process of adipocyte differentiation. Findings suggest that visfatin may be actively involved in the control of weight regulatory networks. However, to what extent and which role it plays in eating disorders is still poorly understood, as mixed results have been reported. The aim of the current study was to investigate serum visfatin concentrations on a cross sectional sample between acute anorexia nervosa patients (n=44), weight recovered patients (n=13) and healthy controls (n=46) and a longitudinal sample of acute patients (n=57) during weight recovery at three different time-points. Results did not show significant differences in visfatin between the three groups; however, acute patients showed a higher visfatin/BMI-SDS ratio than controls and recovered patients. Longitudinal results revealed an increase of visfatin levels during therapy. Our results suggest that high ratios of visfatin/BMI-SDS could be a state marker in acute anorexia nervosa, displaying a compensatory mechanism of the individual to maintain normal visfatin levels under malnourished conditions. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Development and Validation of a Real-Time PCR Assay for Rapid Detection of Candida auris from Surveillance Samples

    PubMed Central

    Leach, L.; Zhu, Y.

    2017-01-01

    ABSTRACT Candida auris is an emerging multidrug-resistant yeast causing invasive health care-associated infection with high mortality worldwide. Rapid identification of C. auris is of primary importance for the implementation of public health measures to control the spread of infection. To achieve these goals, we developed and validated a TaqMan-based real-time PCR assay targeting the internal transcribed spacer 2 (ITS2) region of the ribosomal gene. The assay was highly specific, reproducible, and sensitive, with the detection limit of 1 C. auris CFU/PCR. The performance of the C. auris real-time PCR assay was evaluated by using 623 surveillance samples, including 365 patient swabs and 258 environmental sponges. Real-time PCR yielded positive results from 49 swab and 58 sponge samples, with 89% and 100% clinical sensitivity with regard to their respective culture-positive results. The real-time PCR also detected C. auris DNA from 1% and 12% of swab and sponge samples with culture-negative results, indicating the presence of dead or culture-impaired C. auris. The real-time PCR yielded results within 4 h of sample processing, compared to 4 to 14 days for culture, reducing turnaround time significantly. The new real-time PCR assay allows for accurate and rapid screening of C. auris and can increase effective control and prevention of this emerging multidrug-resistant fungal pathogen in health care facilities. PMID:29187562

  2. Development and Validation of a Real-Time PCR Assay for Rapid Detection of Candida auris from Surveillance Samples.

    PubMed

    Leach, L; Zhu, Y; Chaturvedi, S

    2018-02-01

    Candida auris is an emerging multidrug-resistant yeast causing invasive health care-associated infection with high mortality worldwide. Rapid identification of C. auris is of primary importance for the implementation of public health measures to control the spread of infection. To achieve these goals, we developed and validated a TaqMan-based real-time PCR assay targeting the internal transcribed spacer 2 ( ITS 2) region of the ribosomal gene. The assay was highly specific, reproducible, and sensitive, with the detection limit of 1 C. auris CFU/PCR. The performance of the C. auris real-time PCR assay was evaluated by using 623 surveillance samples, including 365 patient swabs and 258 environmental sponges. Real-time PCR yielded positive results from 49 swab and 58 sponge samples, with 89% and 100% clinical sensitivity with regard to their respective culture-positive results. The real-time PCR also detected C. auris DNA from 1% and 12% of swab and sponge samples with culture-negative results, indicating the presence of dead or culture-impaired C. auris The real-time PCR yielded results within 4 h of sample processing, compared to 4 to 14 days for culture, reducing turnaround time significantly. The new real-time PCR assay allows for accurate and rapid screening of C. auris and can increase effective control and prevention of this emerging multidrug-resistant fungal pathogen in health care facilities. Copyright © 2018 Leach et al.

  3. Influence of uranium on bacterial communities: a comparison of natural uranium-rich soils with controls.

    PubMed

    Mondani, Laure; Benzerara, Karim; Carrière, Marie; Christen, Richard; Mamindy-Pajany, Yannick; Février, Laureline; Marmier, Nicolas; Achouak, Wafa; Nardoux, Pascal; Berthomieu, Catherine; Chapon, Virginie

    2011-01-01

    This study investigated the influence of uranium on the indigenous bacterial community structure in natural soils with high uranium content. Radioactive soil samples exhibiting 0.26% - 25.5% U in mass were analyzed and compared with nearby control soils containing trace uranium. EXAFS and XRD analyses of soils revealed the presence of U(VI) and uranium-phosphate mineral phases, identified as sabugalite and meta-autunite. A comparative analysis of bacterial community fingerprints using denaturing gradient gel electrophoresis (DGGE) revealed the presence of a complex population in both control and uranium-rich samples. However, bacterial communities inhabiting uraniferous soils exhibited specific fingerprints that were remarkably stable over time, in contrast to populations from nearby control samples. Representatives of Acidobacteria, Proteobacteria, and seven others phyla were detected in DGGE bands specific to uraniferous samples. In particular, sequences related to iron-reducing bacteria such as Geobacter and Geothrix were identified concomitantly with iron-oxidizing species such as Gallionella and Sideroxydans. All together, our results demonstrate that uranium exerts a permanent high pressure on soil bacterial communities and suggest the existence of a uranium redox cycle mediated by bacteria in the soil.

  4. Influence of Uranium on Bacterial Communities: A Comparison of Natural Uranium-Rich Soils with Controls

    PubMed Central

    Mondani, Laure; Benzerara, Karim; Carrière, Marie; Christen, Richard; Mamindy-Pajany, Yannick; Février, Laureline; Marmier, Nicolas; Achouak, Wafa; Nardoux, Pascal; Berthomieu, Catherine; Chapon, Virginie

    2011-01-01

    This study investigated the influence of uranium on the indigenous bacterial community structure in natural soils with high uranium content. Radioactive soil samples exhibiting 0.26% - 25.5% U in mass were analyzed and compared with nearby control soils containing trace uranium. EXAFS and XRD analyses of soils revealed the presence of U(VI) and uranium-phosphate mineral phases, identified as sabugalite and meta-autunite. A comparative analysis of bacterial community fingerprints using denaturing gradient gel electrophoresis (DGGE) revealed the presence of a complex population in both control and uranium-rich samples. However, bacterial communities inhabiting uraniferous soils exhibited specific fingerprints that were remarkably stable over time, in contrast to populations from nearby control samples. Representatives of Acidobacteria, Proteobacteria, and seven others phyla were detected in DGGE bands specific to uraniferous samples. In particular, sequences related to iron-reducing bacteria such as Geobacter and Geothrix were identified concomitantly with iron-oxidizing species such as Gallionella and Sideroxydans. All together, our results demonstrate that uranium exerts a permanent high pressure on soil bacterial communities and suggest the existence of a uranium redox cycle mediated by bacteria in the soil. PMID:21998695

  5. Reliability of three bulk-tank antimicrobial residue detection assays used to test individual milk samples from cows with mild clinical mastitis.

    PubMed

    Gibbons-Burgener, S N; Kaneene, J B; Lloyd, J W; Leykam, J F; Erskine, R J

    2001-11-01

    To determine the likelihood of false-positive results when testing milk samples from individual cows by use of 3 commercially available assays (Penzyme MilkTest and the SNAP beta-lactam and Delvo-SP assays) labeled for use with commingled milk. Milk samples from 111 cows with mild clinical mastitis. Cows were randomly assigned to the control (no antimicrobials) or intramammary treatment group. Posttreatment milk samples were collected at the first milking after the labeled withholding period or an equivalent time for controls, randomly ordered, and tested twice by use of each assay and once by use of high-performance liquid chromatography. Sensitivity, specificity, and positive and negative predictive values were determined for each assay. Concordance of results for the same sample was assessed for each assay by calculating kappa. Sensitivities of the Delvo-SP and SNAP lactam assays were > 90%, whereas the sensitivity of the Penzyme Milk Test was 60%. Positive predictive values (range, 39.29 to 73.68%) were poor for all 3 assays. Concordance of test results was excellent for the SNAP beta-lactam and Delvo-SP assays (kappa = 0.846 and 0.813, respectively) but was less for the Penzyme MilkTest (kappa = 0.545). Because of the low positive predictive values, these 3 assays may not be useful for detecting violative antimicrobial residues in individual milk samples from cows treated for mild clinical mastitis. However, repeatability of each assay was considered good to excellent.

  6. A comparative study of Sephadex, glass wool and Percoll separation techniques on sperm quality and IVF results for cryopreserved bovine semen.

    PubMed

    Lee, Hae-Lee; Kim, Sue-Hee; Ji, Dong-Beom; Kim, Yong-Jun

    2009-09-01

    The aim of this study was to compare the effects of spermatozoa separation techniques on sperm quality and in-vitro fertilization (IVF) results for cryopreserved bovine semen. Sephadex, glass wool and Percoll gradient separation techniques were used for sperm separation and sperm motility, morphology and membrane integrity were evaluated before and after separation. Also, cleavage and blastocyst developmental rate were investigated after IVF with sperm recovered by each separation technique. The motility of samples obtained by the three separation techniques were greater compared to the control samples (p < 0.05). The percentage of spermatozoa with intact plasma-membrane integrity, identified by 6-carboxyfluoresceindiacetate/ propidium iodide fluorescent staining and the hypo-osmotic swelling test, was highest in the glass wool filtration samples (p < 0.05). The cleavage and blastocyst rate of total oocytes produced from glass wool filtration samples were also higher than the control and Sephadex filtration samples (p < 0.05), but were not significantly different from Percoll separation samples. However, a significantly greater number of cleaved embryos produced by glass wool filtration developed to blastocyst stage than those produced by Percoll separation (p < 0.05). These results indicate that spermatozoa with good quality can be achieved by these three separation techniques and can be used for bovine IVF. In particular, it suggests that glass wool filtration would be the most effective method of the three for improving sperm quality and embryo production for cryopreserved bovine spermatozoa.

  7. Ground-Water Quality Data in the San Francisco Bay Study Unit, 2007: Results from the California GAMA Program

    USGS Publications Warehouse

    Ray, Mary C.; Kulongoski, Justin T.; Belitz, Kenneth

    2009-01-01

    Ground-water quality in the approximately 620-square-mile San Francisco Bay study unit (SFBAY) was investigated from April through June 2007 as part of the Priority Basin project of the Ground-Water Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin project was developed in response to the Groundwater Quality Monitoring Act of 2001, and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The study was designed to provide a spatially unbiased assessment of raw ground-water quality, as well as a statistically consistent basis for comparing water quality throughout California. Samples in SFBAY were collected from 79 wells in San Francisco, San Mateo, Santa Clara, Alameda, and Contra Costa Counties. Forty-three of the wells sampled were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study unit (grid wells). Thirty-six wells were sampled to aid in evaluation of specific water-quality issues (understanding wells). The ground-water samples were analyzed for a large number of synthetic organic constituents (volatile organic compounds [VOC], pesticides and pesticide degradates, pharmaceutical compounds, and potential wastewater-indicator compounds), constituents of special interest (perchlorate and N-nitrosodimethylamine [NDMA]), naturally occurring inorganic constituents (nutrients, major and minor ions, trace elements, chloride and bromide isotopes, and uranium and strontium isotopes), radioactive constituents, and microbial indicators. Naturally occurring isotopes (tritium, carbon-14 isotopes, and stable isotopes of hydrogen, oxygen, nitrogen, boron, and carbon), and dissolved noble gases (noble gases were analyzed in collaboration with Lawrence Livermore National Laboratory) also were measured to help identify the source and age of the sampled ground water. Quality-control samples (blank samples, replicate samples, matrix spike samples) were collected for approximately one-third of the wells, and the results for these samples were used to evaluate the quality of the data for the ground-water samples. Assessment of the quality-control information from the field blanks resulted in applying 'V' codes to approximately 0.1 percent of the data collected for ground-water samples (meaning a constituent was detected in blanks as well as the corresponding environmental data). See the Appendix section 'Quality-Control-Sample Results'. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, and (or) blended with other waters to maintain acceptable water quality. Regulatory thresholds apply to treated water that is delivered to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with regulatory and non-regulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH) and thresholds established for aesthetic concerns (secondary maximum contaminant levels, SMCL-CA) by CDPH. VOCs were detected in about one-half of the grid wells, while pesticides were detected in about one-fifth of the grid wells. Concentrations of all VOCs and pesticides detected in samples from all SFBAY wells were below health-based thresholds. No pharmaceutical compounds were detected in any SFBAY well. One potential wastewater-indicator compound, caffeine, was detected in one grid well in SFBAY. Concentrations of most trace elements and nutrients detected in samples from all SFBAY wells were below health-based thresholds. Exceptions include nitrate, detected above the USEPA maximum contaminant level (MCL-US) in 3samples; arsenic, above the USEPA maximum contaminant level (MCL-US) in 3 samples; c

  8. Controlling aliased dynamics in motion systems? An identification for sampled-data control approach

    NASA Astrophysics Data System (ADS)

    Oomen, Tom

    2014-07-01

    Sampled-data control systems occasionally exhibit aliased resonance phenomena within the control bandwidth. The aim of this paper is to investigate the aspect of these aliased dynamics with application to a high performance industrial nano-positioning machine. This necessitates a full sampled-data control design approach, since these aliased dynamics endanger both the at-sample performance and the intersample behaviour. The proposed framework comprises both system identification and sampled-data control. In particular, the sampled-data control objective necessitates models that encompass the intersample behaviour, i.e., ideally continuous time models. Application of the proposed approach on an industrial wafer stage system provides a thorough insight and new control design guidelines for controlling aliased dynamics.

  9. Impulse-control disorders in a college sample: results from the self-administered Minnesota Impulse Disorders Interview (MIDI).

    PubMed

    Odlaug, Brian L; Grant, Jon E

    2010-01-01

    This study sought to examine the prevalence rates of and gender differences among impulse-control disorders in a college sample. During the fall semester of 2006, 791 college students from 2 private colleges in the Midwest completed a self-administered, modified version of the Minnesota Impulse Disorders Interview to assess lifetime rates of DSM-IV-TR-diagnosed impulse-control disorders. Participation was voluntary and anonymous. The mean age of the sample was 20.0 +/- 1.25 years, with females comprising 67.9% of the respondents. Of the individuals, 10.4% (n = 82) met criteria for at least 1 lifetime impulse-control disorder. The most common disorders were trichotillomania (3.91%) and compulsive sexual behavior (3.66%). Kleptomania was the least common (0.38%). Males were significantly more likely to screen positive for pathological gambling (P = .003) and compulsive sexual behavior (P = .002). Females were more likely to have compulsive buying (P = .033). Impulse-control disorders appear to be common among college students. The high rates indicate that these disorders may be incipient during late adolescence and early adulthood and should be addressed prior to onset of clinical versions of the impulse-control disorder.

  10. A state observer for using a slow camera as a sensor for fast control applications

    NASA Astrophysics Data System (ADS)

    Gahleitner, Reinhard; Schagerl, Martin

    2013-03-01

    This contribution concerns about a problem that often arises in vision based control, when a camera is used as a sensor for fast control applications, or more precisely, when the sample rate of the control loop is higher than the frame rate of the camera. In control applications for mechanical axes, e.g. in robotics or automated production, a camera and some image processing can be used as a sensor to detect positions or angles. The sample time in these applications is typically in the range of a few milliseconds or less and this demands the use of a camera with a high frame rate up to 1000 fps. The presented solution is a special state observer that can work with a slower and therefore cheaper camera to estimate the state variables at the higher sample rate of the control loop. To simplify the image processing for the determination of positions or angles and make it more robust, some LED markers are applied to the plant. Simulation and experimental results show that the concept can be used even if the plant is unstable like the inverted pendulum.

  11. Issues in the analyze of low content gold mining samples by fire assay technique

    NASA Astrophysics Data System (ADS)

    Cetean, Valentina

    2016-04-01

    The classic technique analyze of samples with low gold content - below 0.1 g/t (=100 ppb = parts per billion), either ore or gold sediments, involves the preparation of sample by fire assay extraction, followed by the chemical attack with aqua regia (hydrochloric and nitric acid) and measuring the gold content by atomic absorption spectrometry or inductively coupled mass spectrometry. The issues raised by this analysis are well known for the world laboratories, commercial or research ones. The author's knowledge regarding this method of determining the gold content, accumulated in such laboratory from Romania (with more than 40 years of experience, even if not longer available from 2014) confirms the obtaining of reliable results required a lot of attention, amount of work and the involving of an experienced fire assayer specialist. The analytical conclusion for a research laboratory is that most reliable and statistically valid results are till reached for samples with more than 100 ppb gold content; the degree of confidence below this value is lower than 90%. Usually, for samples below 50 ppb, it does not exceed 50-70 %, unless without very strictly control of each stage, that involve additional percentage of hours allocated for successive extracting tests and knowing more precisely the other compounds that appear in the sample (Cu, Sb, As, sulfur / sulphides, Te, organic matter, etc.) or impurities. The most important operation is the preparation, namely: - grinding and splitting of sample (which can cause uneven distribution of gold flakes in the double samples for analyzed); - pyro-metallurgical recovery of gold = fire assay stage, involving the more precise temperature control in furnace during all stages (fusion and cupellation) and adjusting of the fire assay flux components to produce a successful fusion depending of the sample matrix and content; - reducing the sample weight to decrease the amount of impurities that can be concentrated in the lead button during oxidation stage. The better metal recovery and the decreasing of the amount of errors for low gold content samples are controlled in this case by: - the management of the quantity of one or more components of the flux, depending on the chemical composition of the sample (sometimes just by observing the behavior and the visual characteristics of lead Au + Ag button/bead and the resulted slag); - addition of gold-free silver, which will be removed by chemical reduction with aqua regia after the fire assay stage. Regarding the instrumental analyze stage of the samples with less than 100 ppb gold content, there were obtained similar values by both techniques: atomic absorption and inductively coupled mass spectrometry, taking into account each of them has different detection limit. It is mandatory the quality control with a certified reference material with known content, both in the fire assay stage and the reading instrumental stage. This abstract are written in the frame of the SUSMIN project: "Tools for sustainable gold mining in EU".

  12. Voxel-based morphometry analysis reveals frontal brain differences in participants with ADHD and their unaffected siblings

    PubMed Central

    Bralten, Janita; Greven, Corina U.; Franke, Barbara; Mennes, Maarten; Zwiers, Marcel P.; Rommelse, Nanda N.J.; Hartman, Catharina; van der Meer, Dennis; O’Dwyer, Laurence; Oosterlaan, Jaap; Hoekstra, Pieter J.; Heslenfeld, Dirk; Arias-Vasquez, Alejandro; Buitelaar, Jan K.

    2016-01-01

    Background Data on structural brain alterations in patients with attention-deficit/hyperactivity disorder (ADHD) have been inconsistent. Both ADHD and brain volumes have a strong genetic loading, but whether brain alterations in patients with ADHD are familial has been underexplored. We aimed to detect structural brain alterations in adolescents and young adults with ADHD compared with healthy controls. We examined whether these alterations were also found in their unaffected siblings, using a uniquely large sample. Methods We performed voxel-based morphometry analyses on MRI scans of patients with ADHD, their unaffected siblings and typically developing controls. We identified brain areas that differed between participants with ADHD and controls and investigated whether these areas were different in unaffected siblings. Influences of medication use, age, sex and IQ were considered. Results Our sample included 307 patients with ADHD, 169 unaffected siblings and 196 typically developing controls (mean age 17.2 [range 8–30] yr). Compared with controls, participants with ADHD had significantly smaller grey matter volume in 5 clusters located in the precentral gyrus, medial and orbitofrontal cortex, and (para)cingulate cortices. Unaffected siblings showed intermediate volumes significantly different from controls in 4 of these clusters (all except the precentral gyrus). Medication use, age, sex and IQ did not have an undue influence on the results. Limitations Our sample was heterogeneous, most participants with ADHD were taking medication, and the comparison was cross-sectional. Conclusion Brain areas involved in decision making, motivation, cognitive control and motor functioning were smaller in participants with ADHD than in controls. Investigation of unaffected siblings indicated familiality of 4 of the structural brain differences, supporting their potential in molecular genetic analyses in ADHD research. PMID:26679925

  13. Systematic screening with information and home sampling for genital Chlamydia trachomatis infections in young men and women in Norway: a randomized controlled trial.

    PubMed

    Kløvstad, Hilde; Natås, Olav; Tverdal, Aage; Aavitsland, Preben

    2013-01-23

    As most genital Chlamydia trachomatis infections are asymptomatic, many patients do not seek health care for testing. Infections remain undiagnosed and untreated. We studied whether screening with information and home sampling resulted in more young people getting tested, diagnosed and treated for chlamydia in the three months following the intervention compared to the current strategy of testing in the health care system. We conducted a population based randomized controlled trial among all persons aged 18-25 years in one Norwegian county (41 519 persons). 10 000 persons (intervention) received an invitation by mail with chlamydia information and a mail-back urine sampling kit. 31 519 persons received no intervention and continued with usual care (control). All samples from both groups were analysed in the same laboratory. Information on treatment was obtained from the Norwegian Prescription Database (NorPD). We estimated risk ratios and risk differences of being tested, diagnosed and treated in the intervention group compared to the control group. In the intervention group 16.5% got tested and in the control group 3.4%, risk ratio 4.9 (95% CI 4.5-5.2). The intervention led to 2.6 (95% CI 2.0-3.4) times as many individuals being diagnosed and 2.5 (95% CI 1.9-3.4) times as many individuals receiving treatment for chlamydia compared to no intervention in the three months following the intervention. In Norway, systematic screening with information and home sampling results in more young people being tested, diagnosed and treated for chlamydia in the three months following the intervention than the current strategy of testing in the health care system. However, the study has not established that the intervention will reduce the chlamydia prevalence or the risk of complications from chlamydia.

  14. A VLF-based technique in applications to digital control of nonlinear hybrid multirate systems

    NASA Astrophysics Data System (ADS)

    Vassilyev, Stanislav; Ulyanov, Sergey; Maksimkin, Nikolay

    2017-01-01

    In this paper, a technique for rigorous analysis and design of nonlinear multirate digital control systems on the basis of the reduction method and sublinear vector Lyapunov functions is proposed. The control system model under consideration incorporates continuous-time dynamics of the plant and discrete-time dynamics of the controller and takes into account uncertainties of the plant, bounded disturbances, nonlinear characteristics of sensors and actuators. We consider a class of multirate systems where the control update rate is slower than the measurement sampling rates and periodic non-uniform sampling is admitted. The proposed technique does not use the preliminary discretization of the system, and, hence, allows one to eliminate the errors associated with the discretization and improve the accuracy of analysis. The technique is applied to synthesis of digital controller for a flexible spacecraft in the fine stabilization mode and decentralized controller for a formation of autonomous underwater vehicles. Simulation results are provided to validate the good performance of the designed controllers.

  15. Space Station CMIF extended duration metabolic control test

    NASA Technical Reports Server (NTRS)

    Schunk, Richard G.; Bagdigian, Robert M.; Carrasquillo, Robyn L.; Ogle, Kathryn Y.; Wieland, Paul O.

    1989-01-01

    The Space Station Extended Duration Metabolic Control Test (EMCT) was conducted at the MSFC Core Module Integration Facility. The primary objective of the EMCT was to gather performance data from a partially-closed regenerative Environmental Control and Life Support (ECLS) system functioning under steady-state conditions. Included is a description of the EMCT configuration, a summary of events, a discussion of anomalies that occurred during the test, and detailed results and analysis from individual measurements of water and gas samples taken during the test. A comparison of the physical, chemical, and microbiological methods used in the post test laboratory analyses of the water samples is included. The preprototype ECLS hardware used in the test, providing an overall process description and theory of operation for each hardware item. Analytical results pertaining to a system level mass balance and selected system power estimates are also included.

  16. The Development and Use of Internal Amplification Controls (IACs) with DNA Profiling Kits for Forensic DNA Analysis.

    PubMed

    Zahra, Nathalie; Goodwin, William

    2016-01-01

    Biological samples recovered for forensic investigations are often degraded and/or have low amounts of DNA; in addition, in some instances the samples may be contaminated with chemicals that can act as PCR inhibitors. As a consequence this can make interpretation of the results challenging with the possibility of having partial profiles and false negative results. Because of the impact of DNA analysis on forensic investigations, it is important to monitor the process of DNA profiling, in particular the amplification reaction. In this chapter we describe a method for the in-house generation and use of internal amplification controls (IACs) with DNA profiling kits to monitor the success of the PCR proces. In the example we show the use of the SGM Plus® kit. These controls can also be used to aid the interpretation of the DNA profile.

  17. Investigating the factorial structure and availability of work time control in a representative sample of the Swedish working population

    PubMed Central

    Albrecht, Sophie C.; Kecklund, Göran; Tucker, Philip; Leineweber, Constanze

    2015-01-01

    Aims: Past research has often neglected the sub-dimensions of work time control (WTC). Moreover, differences in levels of WTC with respect to work and demographic characteristics have not yet been examined in a representative sample. We investigated these matters in a recent sample of the Swedish working population. Methods: The study was based on the 2014 data collection of the Swedish Longitudinal Occupational Survey of Health. We assessed the structure of the WTC measure using exploratory and confirmatory factor analysis. Differences in WTC by work and demographic characteristics were examined with independent sample t-tests, one-way ANOVAs and gender-stratified logistic regressions. Results: Best model fit was found for a two-factor structure that distinguished between control over daily hours and control over time off (root mean square error of approximation = 0.06; 95% CI 0.04 to 0.09; Comparative Fit Index (CFI) = 0.99). Women, shift and public-sector workers reported lower control in relation to both factors. Age showed small associations with WTC, while a stronger link was suggested for civil status and family situation. Night, roster and rotating shift work seemed to be the most influential factors on reporting low control over daily hours and time off. Conclusions: Our data confirm the two-dimensional structure underlying WTC, namely the components ‘control over daily hours’ and ‘control over time off’. Women, public-sector and shift workers reported lower levels of control. Future research should examine the public health implications of WTC, in particular whether increased control over daily hours and time off can reduce health problems associated with difficult working-time arrangements. PMID:26620363

  18. Antecedents of Emotional Intelligence: An Empirical Study

    ERIC Educational Resources Information Center

    Barbuto, John E., Jr.; Story, Joana S.

    2010-01-01

    This study examined the relationships between emotional intelligence, locus of control, and mental boundaries. Three hundred and eighty-two county employees were sampled using a cross-sectional survey design. The results indicated internal locus of control and thin mental boundaries are positively related to emotional intelligence. A hierarchical…

  19. Cybernetic Control of an Electrochemical Repertoire.

    ERIC Educational Resources Information Center

    He, Peixin; And Others

    1982-01-01

    Describes major features of a computer-operated, cybernetic potentiostat and the development, design, and operation of the software in ROM. The instrument contains control circuitry and software making it compatible with the static mercury drop electrode produced by EG&G Princeton Applied Research Corporation. Sample results using the…

  20. Practical continuous-variable quantum key distribution without finite sampling bandwidth effects.

    PubMed

    Li, Huasheng; Wang, Chao; Huang, Peng; Huang, Duan; Wang, Tao; Zeng, Guihua

    2016-09-05

    In a practical continuous-variable quantum key distribution system, finite sampling bandwidth of the employed analog-to-digital converter at the receiver's side may lead to inaccurate results of pulse peak sampling. Then, errors in the parameters estimation resulted. Subsequently, the system performance decreases and security loopholes are exposed to eavesdroppers. In this paper, we propose a novel data acquisition scheme which consists of two parts, i.e., a dynamic delay adjusting module and a statistical power feedback-control algorithm. The proposed scheme may improve dramatically the data acquisition precision of pulse peak sampling and remove the finite sampling bandwidth effects. Moreover, the optimal peak sampling position of a pulse signal can be dynamically calibrated through monitoring the change of the statistical power of the sampled data in the proposed scheme. This helps to resist against some practical attacks, such as the well-known local oscillator calibration attack.

  1. Comparison of Different Matrices as Potential Quality Control Samples for Neurochemical Dementia Diagnostics.

    PubMed

    Lelental, Natalia; Brandner, Sebastian; Kofanova, Olga; Blennow, Kaj; Zetterberg, Henrik; Andreasson, Ulf; Engelborghs, Sebastiaan; Mroczko, Barbara; Gabryelewicz, Tomasz; Teunissen, Charlotte; Mollenhauer, Brit; Parnetti, Lucilla; Chiasserini, Davide; Molinuevo, Jose Luis; Perret-Liaudet, Armand; Verbeek, Marcel M; Andreasen, Niels; Brosseron, Frederic; Bahl, Justyna M C; Herukka, Sanna-Kaisa; Hausner, Lucrezia; Frölich, Lutz; Labonte, Anne; Poirier, Judes; Miller, Anne-Marie; Zilka, Norbert; Kovacech, Branislav; Urbani, Andrea; Suardi, Silvia; Oliveira, Catarina; Baldeiras, Ines; Dubois, Bruno; Rot, Uros; Lehmann, Sylvain; Skinningsrud, Anders; Betsou, Fay; Wiltfang, Jens; Gkatzima, Olymbia; Winblad, Bengt; Buchfelder, Michael; Kornhuber, Johannes; Lewczuk, Piotr

    2016-03-01

    Assay-vendor independent quality control (QC) samples for neurochemical dementia diagnostics (NDD) biomarkers are so far commercially unavailable. This requires that NDD laboratories prepare their own QC samples, for example by pooling leftover cerebrospinal fluid (CSF) samples. To prepare and test alternative matrices for QC samples that could facilitate intra- and inter-laboratory QC of the NDD biomarkers. Three matrices were validated in this study: (A) human pooled CSF, (B) Aβ peptides spiked into human prediluted plasma, and (C) Aβ peptides spiked into solution of bovine serum albumin in phosphate-buffered saline. All matrices were tested also after supplementation with an antibacterial agent (sodium azide). We analyzed short- and long-term stability of the biomarkers with ELISA and chemiluminescence (Fujirebio Europe, MSD, IBL International), and performed an inter-laboratory variability study. NDD biomarkers turned out to be stable in almost all samples stored at the tested conditions for up to 14 days as well as in samples stored deep-frozen (at - 80°C) for up to one year. Sodium azide did not influence biomarker stability. Inter-center variability of the samples sent at room temperature (pooled CSF, freeze-dried CSF, and four artificial matrices) was comparable to the results obtained on deep-frozen samples in other large-scale projects. Our results suggest that it is possible to replace self-made, CSF-based QC samples with large-scale volumes of QC materials prepared with artificial peptides and matrices. This would greatly facilitate intra- and inter-laboratory QC schedules for NDD measurements.

  2. Active vibration control activities at the LaRC - Present and future

    NASA Technical Reports Server (NTRS)

    Newsom, J. R.

    1990-01-01

    The NASA Controls-Structures-Interaction (CSI) program is presented with a description of the ground testing element objectives and approach. The goal of the CSI program is to develop and validate the technology required to design, verify and operate space systems in which the structure and the controls interact beneficially to meet the needs of future NASA missions. The operational Mini-Mast ground testbed and some sample active vibration control experimental results are discussed along with a description of the CSI Evolutionary Model testbed presently under development. Initial results indicate that embedded sensors and actuators are effective in controlling a large truss/reflector structure.

  3. [677T mutation of the MTHFR gene in adenomas and colorectal cancer in a population sample from the Northeastern Mexico. Preliminary results].

    PubMed

    Delgado-Enciso, I; Martínez-Garza, S G; Rojas-Martínez, A; Ortiz-López, R; Bosques-Padilla, F; Calderón-Garcidueñas, A L; Zárate-Gómez, M; Barrera-Saldaña, H A

    2001-01-01

    Adequate intake of folates has been associated to low prevalence of colon cancer. Methylenetetrahydrofolate reductase enzyme (MTHFR) plays an important role in folate metabolism. The role of the 677 mutation at the MTHFR gene in the risk for colorectal cancer remains controversial. A recent report established that this mutation has a high prevalence in the healthy Mexican population. To analyze the prevalence of 677T MTHFR mutation in patients with colorectal cancer and controls without chronic gastrointestinal disorders. Seventy-four colorectal cancer, 32 adenomas and 110 normal samples were analyzed. Patients and controls were matched for sex and age. For each sample, DNA isolation, PCR, and mutation detection by restriction enzyme digestion were performed to determine the allele at the 677 position in the MTHFR gene. Genotype 677C/677C was found in 18.7, 20.3, and 30.9% in adenomas, cancer lesions and controls, respectively. Frequencies of the 677C/677T genotype were 59.4, 56.7, and 47.3%, in adenomas, cancer lesions, and controls, respectively. Genotype 677T/677T was found in 21.9, 23.0, and 21.8% in adenomas, cancer lesions, and controls, respectively. The odds ratio between genotypes carrying the mutation (T/T and C/T) and normal genotype (CC) was 1.81 (IC 95% 0.97-3.3), chi 2 = 3.5, p = 0.06. Our results showed that persons who carry the 677T mutation at MTHFR locus have a tendency for an increased risk for colorectal cancer. This study supports the basic concept that low levels of folic acid contribute with the colorectal cancer pathogenesis. Our lack of statistic significance may be due to reduced sample size.

  4. Thermal control surfaces on the MSFC LDEF experiments

    NASA Technical Reports Server (NTRS)

    Wilkes, Donald R.; Whitaker, Ann F.; Zwiener, James M.; Linton, Roger C.; Shular, David; Peters, Palmer N.; Gregory, John C.

    1992-01-01

    There were five Marshall Space Flight Center (MSFC) experiments on the LDEF. Each of those experiments carried thermal control surfaces either as test samples or as operational surfaces. These materials experienced varying degrees of mechanical and optical damage. Some materials were virtually unchanged by the extended exposure while others suffered extensive degradation. The synergistic effects due to the constituents of the space environment are evident in the diversity of these material changes. The sample complement for the MSFC experiments is described along with results of the continuing analyses efforts.

  5. Optical effect of the contamination of infrared windows by the outgassing of materials in outer space

    NASA Technical Reports Server (NTRS)

    Silberman, E.

    1975-01-01

    The composition and evaporation rate of the outgassing of a space vehicle thermal control paint as a function of temperature were studied. A contamination chamber was designed, constructed, and tested. Samples of thermal control paint were tested to determine if heating to moderate temperatures causes them to release outgassing products which can be collected on a cooled cesium iodide window for identification by IR analysis. Results showed that outgassing of surfaces other than the sample was a problem. Spectral bands of the deposits collected were compared.

  6. Quantized Synchronization of Chaotic Neural Networks With Scheduled Output Feedback Control.

    PubMed

    Wan, Ying; Cao, Jinde; Wen, Guanghui

    In this paper, the synchronization problem of master-slave chaotic neural networks with remote sensors, quantization process, and communication time delays is investigated. The information communication channel between the master chaotic neural network and slave chaotic neural network consists of several remote sensors, with each sensor able to access only partial knowledge of output information of the master neural network. At each sampling instants, each sensor updates its own measurement and only one sensor is scheduled to transmit its latest information to the controller's side in order to update the control inputs for the slave neural network. Thus, such communication process and control strategy are much more energy-saving comparing with the traditional point-to-point scheme. Sufficient conditions for output feedback control gain matrix, allowable length of sampling intervals, and upper bound of network-induced delays are derived to ensure the quantized synchronization of master-slave chaotic neural networks. Lastly, Chua's circuit system and 4-D Hopfield neural network are simulated to validate the effectiveness of the main results.In this paper, the synchronization problem of master-slave chaotic neural networks with remote sensors, quantization process, and communication time delays is investigated. The information communication channel between the master chaotic neural network and slave chaotic neural network consists of several remote sensors, with each sensor able to access only partial knowledge of output information of the master neural network. At each sampling instants, each sensor updates its own measurement and only one sensor is scheduled to transmit its latest information to the controller's side in order to update the control inputs for the slave neural network. Thus, such communication process and control strategy are much more energy-saving comparing with the traditional point-to-point scheme. Sufficient conditions for output feedback control gain matrix, allowable length of sampling intervals, and upper bound of network-induced delays are derived to ensure the quantized synchronization of master-slave chaotic neural networks. Lastly, Chua's circuit system and 4-D Hopfield neural network are simulated to validate the effectiveness of the main results.

  7. A Study of Pupil Control Ideology: A Person-Oriented Approach to Data Analysis

    ERIC Educational Resources Information Center

    Adwere-Boamah, Joseph

    2010-01-01

    Responses of urban school teachers to the Pupil Control Ideology questionnaire were studied using Latent Class Analysis. The results of the analysis suggest that the best fitting model to the data is a two-cluster solution. In particular, the pupil control ideology of the sample delineates into two clusters of teachers, those with humanistic and…

  8. An Empirical Examination of the Construct Validity of Two Alternative Self-Control Measures.

    ERIC Educational Resources Information Center

    Marcus, Bernd

    2003-01-01

    Contrasted a new measure of self-control, the Retrospective Behavioral Self-Control scale (RBS), with the most widespread measure of this construct (H. Grasmick and others, 1993). Results show that the RBS measured the general factor of behavior across samples of 214 and 213 undergraduates and 76 employees, but the other scale, used with only one…

  9. Learning Model and Form of Assesment toward the Inferensial Statistical Achievement by Controlling Numeric Thinking Skills

    ERIC Educational Resources Information Center

    Widiana, I. Wayan; Jampel, I. Nyoman

    2016-01-01

    This study aimed to find out the effect of learning model and form of assessment toward inferential statistical achievement after controlling numeric thinking skills. This study was quasi experimental study with 130 students as the sample. The data analysis used ANCOVA. After controlling numeric thinking skills, the result of this study show that:…

  10. Environmental assessment of a wood-waste-fired industrial firetube boiler. Volume 1. Technical results. Final report, January 1981-March 1984

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeRosier, R.; Waterland, L.R.

    1987-03-01

    The report gives emission results from field tests of a wood-waste-fired industrial firetube boiler. Emission measurements included: continuous monitoring of flue gas emissions: source assessment sampling system (SASS) sampling of the flue-gas with subsequent laboratory analysis of samples to give total flue gas organics in two boiling point ranges, compound category information within these ranges, specific quantitation of the semivolatile organic priority pollutants, and flue gas concentrations of 65 trace elements; Method 5 sampling for particulates; controlled condensation system (CSS) sampling for SO/sub 2/ and SO/sub 3/; and grab sampling of boiler bottom ash for trace element content determinations. Totalmore » organic emissions from the boiler were 5.7 mg/dscm, about 90% of which consisted of volatile compounds.« less

  11. Outgassing and dimensional changes of polymer matrix composites in space

    NASA Technical Reports Server (NTRS)

    Tennyson, R. C.; Matthews, R.

    1993-01-01

    A thermal-vacuum outgassing model and test protocol for predicting outgassing times and dimensional changes for polymer matrix composites is described. Experimental results derived from a 'control' sample are used to provide the basis for analytical predictions to compare with the outgassing response of Long Duration Exposure Facility (LDEF) flight samples.

  12. WATER TREATMENT

    DOEpatents

    Pitman, R.W.; Conley, W.R. Jr.

    1962-12-01

    An automated system for adding clarifying chemicals to water in a water treatment plant is described. To a sample of the floc suspension polyacrylamide or similar filter aid chemicals are added, and the sample is then put through a fast filter. The resulting filtrate has the requisite properties for monitoring in an optical turbidimeter to control the automated system. (AEC)

  13. Relation of Childhood Worry to Information-Processing Factors in an Ethnically Diverse Community Sample

    ERIC Educational Resources Information Center

    Suarez-Morales, Lourdes; Bell, Debora

    2006-01-01

    This study examined information-processing variables in relation to worry in a sample of 292 fifth-grade children from Caucasian, African American, and Hispanic backgrounds. Results revealed that worry was related to threat interpretations for hypothetical situations and, when stress level was not controlled, to higher estimates of future…

  14. Controlling the Biodegradation of Magnesium Implants Through Nanostructured Calcium-Phosphate Coating

    NASA Astrophysics Data System (ADS)

    Iskandar, Maria Emil

    Magnesium (Mg) alloys, a novel class of degradable, metallic biomaterials, have attracted growing interest as a promising alternative for medical implant and device applications due to their advantageous mechanical and biological properties. Moreover, Mg is biodegradable in the physiological environments. However, the major obstacle for Mg to be used as medical implants is its rapid degradation in physiological fluids. Therefore, the present key challenge lies in controlling Mg degradation rate in the physiological environment. The objective of this study was to develop a nanostructured-hydroxyapatite (nHA) coating on polished Mg implants to control the degradation and bone tissue integration of the implants. The nHA coatings were deposited on Mg using the Spire's patented TPA process to moderate the aggressive degradation of Mg and to improve quick osteointegration between Mg and natural bone. Nanostructured-HA coatings mimic the nanostructure and chemistry of natural bone, which will provide a desirable environment for bone tissue regeneration. Surface morphology, element compositions, and crystal structures were characterized using scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), and x-ray diffractometry (XRD), respectively. SEM images of the deposited nHA-coating was analyzed using ImageJ's quantitative image analysis tool, to determine the nHA-coating particle size and thickness. The degradation of nHA-coated and non-coated Mg samples was investigated by incubating samples in phosphate buffered saline (PBS) and revised simulated body fluid (r-SBF), under standard cell culture conditions. To mimic the in vivo cell response in the physiological environment, rat bone marrow stromal cells (BMSC) were harvested and cultured with nHA-coated and non-coated polished Mg samples to determine cytocompatibilty. The degradation results suggested that the nanocoatings positively mediated Mg degradation. It can therefore be concluded that nHA-coatings show promise for controlling the biodegradation of Mg-based orthopedic implants and devices. Cell studies indicated significantly improved BMSC adhesion on the surfaces of the nHA-coated and non-coated Mg samples, in comparison to the cells surrounding the Mg samples. These results indicated that the nHA-coated and non-coated Mg samples promote cell activity on the surface. However, cell experiments must be repeated on a larger number of samples with extensive short and long term cell studies, to achieve more verifiable results.

  15. Genetic variation in avocado stem weevils Copturus aguacatae (Coleoptera: Curculionidae) in Mexico.

    PubMed

    Engstrand, Rachel C; Cibrián Tovar, Juan; Cibrián-Jaramillo, Angélica; Kolokotronis, Sergios-Orestis

    2010-12-01

    The avocado stem weevil Copturus aguacatae is an important pest in avocado plantations. Its presence hinders the production and marketing of avocado in Mexico, the largest avocado producer worldwide. Biological control through pheromone synthesis, a strategy favored over chemical control in crops, is currently limited by difficult field identification of this species. Using DNA barcoding, we examine the patterns of genetic variation of C. aguacatae in avocado trees in Mexico to help facilitate its identification and biological control. We show that there is one single species of avocado stem weevil throughout the sampled sites in Mexico. Overall, haplotype diversity is high, with Oaxaca forming one distinct group and all other sampled populations are admixed irrespective of geographic origin. The results suggest that high gene flow is maintained in this species and that a global strategy for biocontrol can be designed and implemented throughout the sampled range.

  16. Effective Coping With Supervisor Conflict Depends on Control: Implications for Work Strains.

    PubMed

    Eatough, Erin M; Chang, Chu-Hsiang

    2018-01-11

    This study examined the interactive effects of interpersonal conflict at work, coping strategy, and perceived control specific to the conflict on employee work strain using multisource and time-lagged data across two samples. In Sample 1, multisource data was collected from 438 employees as well as data from participant-identified secondary sources (e.g., significant others, best friends). In Sample 2, time-lagged data from 100 full-time employees was collected in a constructive replication. Overall, findings suggested that the success of coping efforts as indicated by lower strains hinges on the combination of the severity of the stressor, perceived control over the stressor, and coping strategy used (problem-focused vs. emotion-focused coping). Results from the current study provide insights for why previous efforts to document the moderating effects of coping have been inconsistent, especially with regards to emotion-focused coping. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  17. The WWW as a research medium: an illustrative survey on paranormal belief.

    PubMed

    Göritz, A S; Schumacher, J

    2000-06-01

    Data collected with a short World Wide Web (WWW) survey on paranormal belief, age, sex, locus of control, extraversion, emotional and physical well-being, and mood were compared with findings from recent literature while controlling for effects of self-selection. Each variable was measured with one item. The sample comprised 342 women, 648 men, and 8 participants of unknown sex, of whom 76.7% were self-selected and 23.3% did not select themselves. There was a weak but, given the large sample, significant effect of self-selection regarding paranormal belief (rpb 932 = .08) but no relationships for paranormal belief and the examined variables. In the entire sample, statistically significant correlations ranging from .13 to .07 between paranormal belief and female sex, scores on external locus of control, good mood, extraversion, and emotional well-being corresponded with previous offline results.

  18. Biological monitoring of glazers exposed to lead in the ceramics industry in Iran.

    PubMed

    Shouroki, Fatemeh Kargar; Shahtaheri, Seyed Jamaleddin; Golbabaei, Farideh; Barkhordari, Abolfazle; Rahimi-Froushani, Abbas

    2015-01-01

    Exposure to heavy metals, particularly lead, takes place in the ceramics industry. Lead is used in glaze to produce smooth and brilliant surfaces; thus, there is a likelihood of occupational adverse effects on humans. Urine samples were collected from 49 glazers at the start and end of the work shifts (98 samples). Solid phase extraction was used for separation and pre-concentration of the analyte. Samples were analysed by inductively coupled plasma-atomic emission spectroscopy (ICP-AES). Lung function tests were performed on both control and lead exposed subjects. Statistical analysis of covariance (ANCOVA) was used to evaluate the data obtained. The concentration of lead in glazers was 6.37 times higher than in the control group. Lung functions were significantly lower in the glazers compared to the control group (p < 0.001). Results showed that poor ventilation systems, overtime work and work history are effective determinants of high exposure levels.

  19. Binary effect of fly ash and palm oil fuel ash on heat of hydration aerated concrete.

    PubMed

    Mehmannavaz, Taha; Ismail, Mohammad; Radin Sumadi, Salihuddin; Rafique Bhutta, Muhammad Aamer; Samadi, Mostafa; Sajjadi, Seyed Mahdi

    2014-01-01

    The binary effect of pulverized fuel ash (PFA) and palm oil fuel ash (POFA) on heat of hydration of aerated concrete was studied. Three aerated concrete mixes were prepared, namely, concrete containing 100% ordinary Portland cement (control sample or Type I), binary concrete made from 50% POFA (Type II), and ternary concrete containing 30% POFA and 20% PFA (Type III). It is found that the temperature increases due to heat of hydration through all the concrete specimens especially in the control sample. However, the total temperature rises caused by the heat of hydration through both of the new binary and ternary concrete were significantly lower than the control sample. The obtained results reveal that the replacement of Portland cement with binary and ternary materials is beneficial, particularly for mass concrete where thermal cracking due to extreme heat rise is of great concern.

  20. Binary Effect of Fly Ash and Palm Oil Fuel Ash on Heat of Hydration Aerated Concrete

    PubMed Central

    Mehmannavaz, Taha; Ismail, Mohammad; Radin Sumadi, Salihuddin; Rafique Bhutta, Muhammad Aamer; Samadi, Mostafa

    2014-01-01

    The binary effect of pulverized fuel ash (PFA) and palm oil fuel ash (POFA) on heat of hydration of aerated concrete was studied. Three aerated concrete mixes were prepared, namely, concrete containing 100% ordinary Portland cement (control sample or Type I), binary concrete made from 50% POFA (Type II), and ternary concrete containing 30% POFA and 20% PFA (Type III). It is found that the temperature increases due to heat of hydration through all the concrete specimens especially in the control sample. However, the total temperature rises caused by the heat of hydration through both of the new binary and ternary concrete were significantly lower than the control sample. The obtained results reveal that the replacement of Portland cement with binary and ternary materials is beneficial, particularly for mass concrete where thermal cracking due to extreme heat rise is of great concern. PMID:24696646

  1. Thermoelectric technique to precisely control hyperthermic exposures of human whole blood.

    PubMed

    DuBose, D A; Langevin, R C; Morehouse, D H

    1996-12-01

    The need in military research to avoid exposing humans to harsh environments and reduce animal use requires the development of in vitro models for the study of hyperthermic injury. A thermoelectric module (TEM) system was employed to heat human whole blood (HWB) in a manner similar to that experienced by heat-stroked rats. This system precisely and accurately replicated mild, moderate, and extreme heat-stress exposures. Temperature changes could be monitored without the introduction of a test sample thermistor, which reduced contamination problems. HWB with hematocrits of 45 or 50% had similar heating curves, indicating that the system compensated for differences in sample character. The unit's size permitted its containment within a standard carbon dioxide incubator to further control sample environment. These results indicate that the TEM system can precisely control temperature change in this heat stress in vitro model employing HWB. Information obtained from such a model could contribute to military preparedness.

  2. IOTA: the array controller for a gigapixel OTCCD camera for Pan-STARRS

    NASA Astrophysics Data System (ADS)

    Onaka, Peter; Tonry, John; Luppino, Gerard; Lockhart, Charles; Lee, Aaron; Ching, Gregory; Isani, Sidik; Uyeshiro, Robin

    2004-09-01

    The PanSTARRS project has undertaken an ambitious effort to develop a completely new array controller architecture that is fundamentally driven by the large 1gigapixel, low noise, high speed OTCCD mosaic requirements as well as the size, power and weight restrictions of the PanSTARRS telescope. The result is a very small form factor next generation controller scalar building block with 1 Gigabit Ethernet interfaces that will be assembled into a system that will readout 512 outputs at ~1 Megapixel sample rates on each output. The paper will also discuss critical technology and fabrication techniques such as greater than 1MHz analog to digital converters (ADCs), multiple fast sampling and digital calculation of multiple correlated samples (DMCS), ball grid array (BGA) packaged circuits, LINUX running on embedded field programmable gate arrays (FPGAs) with hard core microprocessors for the prototype currently being developed.

  3. Effect of fast pyrolysis bio-oil from palm oil empty fruit bunch on bitumen properties

    NASA Astrophysics Data System (ADS)

    Poh, Chia Chin; Hassan, Norhidayah Abdul; Raman, Noor Azah Abdul; Shukry, Nurul Athma Mohd; Warid, Muhammad Naqiuddin Mohd; Satar, Mohd Khairul Idham Mohd; Ros Ismail, Che; Asmah Hassan, Sitti; Mashros, Nordiana

    2018-04-01

    Bitumen shortage has triggered the exploration of another alternative waste material that can be blended with conventional bitumen. This study presents the performance of pyrolysis bio-oil from palm oil empty fruit bunch (EFB) as an alternative binder in modified bitumen mixtures. The palm oil EFB was first pyrolyzed using auger pyrolyzer to extract the bio-oil. Conventional bitumen 80/100 penetration grade was used as a control sample and compared with samples that were modified with different percentages, i.e., 5% and 10%, of pyrolysis EFB bio-oil. The physical and rheological properties of the control and modified bitumen samples were investigated using penetration, softening point, viscosity and dynamic shear rheometer (DSR) tests. Results showed that the addition of EFB bio-oil softened the bitumen with high penetration and a reduction in softening point, penetration index, and viscosity. However, the DSR results showed a comparable rutting resistance between the bitumen samples containing EFB bio-oil and virgin bitumen with a failure temperature achieved greater than 64°C.

  4. Gas-Purged Headspace Liquid Phase Microextraction System for Determination of Volatile and Semivolatile Analytes

    PubMed Central

    Zhang, Meihua; Bi, Jinhu; Yang, Cui; Li, Donghao; Piao, Xiangfan

    2012-01-01

    In order to achieve rapid, automatic, and efficient extraction for trace chemicals from samples, a system of gas-purged headspace liquid phase microextraction (GP-HS-LPME) has been researched and developed based on the original HS-LPME technique. In this system, semiconductor condenser and heater, whose refrigerating and heating temperatures were controlled by microcontroller, were designed to cool the extraction solvent and to heat the sample, respectively. Besides, inert gas, whose gas flow rate was adjusted by mass flow controller, was continuously introduced into and discharged from the system. Under optimized parameters, extraction experiments were performed, respectively, using GP-HS-LPME system and original HS-LPME technique for enriching volatile and semivolatile target compounds from the same kind of sample of 15 PAHs standard mixture. GC-MS analysis results for the two experiments indicated that a higher enrichment factor was obtained from GP-HS-LPME. The enrichment results demonstrate that GP-HS-LPME system is potential in determination of volatile and semivolatile analytes from various kinds of samples. PMID:22448341

  5. Analytical results from an environmental investigation of six sites on Kirtland Air Force Base, New Mexico, 1993-94

    USGS Publications Warehouse

    Wilcox, Ralph

    1995-01-01

    The six sites investigated include silver recovery units; a buried caustic drain line; a neutralization pit; an evaporation/infiltration pond; the Manzano fire training area; and a waste oil underground storage tank. Environmental samples of soil, pond sediment, soil gas, and water and gas in floor drains were collected and analyzed. Field quality-control samples were also collected and analyzed in association with the environmental samples. The six sites were investigated because past or current activities could have resulted in contamination of soil, pond sediment, or water and sediment in drains.

  6. Analysis of Rare, Exonic Variation amongst Subjects with Autism Spectrum Disorders and Population Controls

    PubMed Central

    Liu, Li; Sabo, Aniko; Neale, Benjamin M.; Nagaswamy, Uma; Stevens, Christine; Lim, Elaine; Bodea, Corneliu A.; Muzny, Donna; Reid, Jeffrey G.; Banks, Eric; Coon, Hillary; DePristo, Mark; Dinh, Huyen; Fennel, Tim; Flannick, Jason; Gabriel, Stacey; Garimella, Kiran; Gross, Shannon; Hawes, Alicia; Lewis, Lora; Makarov, Vladimir; Maguire, Jared; Newsham, Irene; Poplin, Ryan; Ripke, Stephan; Shakir, Khalid; Samocha, Kaitlin E.; Wu, Yuanqing; Boerwinkle, Eric; Buxbaum, Joseph D.; Cook, Edwin H.; Devlin, Bernie; Schellenberg, Gerard D.; Sutcliffe, James S.; Daly, Mark J.; Gibbs, Richard A.; Roeder, Kathryn

    2013-01-01

    We report on results from whole-exome sequencing (WES) of 1,039 subjects diagnosed with autism spectrum disorders (ASD) and 870 controls selected from the NIMH repository to be of similar ancestry to cases. The WES data came from two centers using different methods to produce sequence and to call variants from it. Therefore, an initial goal was to ensure the distribution of rare variation was similar for data from different centers. This proved straightforward by filtering called variants by fraction of missing data, read depth, and balance of alternative to reference reads. Results were evaluated using seven samples sequenced at both centers and by results from the association study. Next we addressed how the data and/or results from the centers should be combined. Gene-based analyses of association was an obvious choice, but should statistics for association be combined across centers (meta-analysis) or should data be combined and then analyzed (mega-analysis)? Because of the nature of many gene-based tests, we showed by theory and simulations that mega-analysis has better power than meta-analysis. Finally, before analyzing the data for association, we explored the impact of population structure on rare variant analysis in these data. Like other recent studies, we found evidence that population structure can confound case-control studies by the clustering of rare variants in ancestry space; yet, unlike some recent studies, for these data we found that principal component-based analyses were sufficient to control for ancestry and produce test statistics with appropriate distributions. After using a variety of gene-based tests and both meta- and mega-analysis, we found no new risk genes for ASD in this sample. Our results suggest that standard gene-based tests will require much larger samples of cases and controls before being effective for gene discovery, even for a disorder like ASD. PMID:23593035

  7. Challenges for conducting blood collection and biochemical analysis in a large multicenter school-based study with adolescents: lessons from ERICA in Brazil.

    PubMed

    Cureau, Felipe Vogt; Bloch, Katia Vergetti; Henz, Aline; Schaan, Camila W; Klein, Carlos Henrique; Oliveira, Cecília Lacroix de; Giannini, Denise Tavares; Leon, Elisa Brosina de; Abreu, Gabriela de Azevedo; Telo, Gabriela Heiden; Dias, Glauber Monteiro; Carvalho, Kênia Mara Baiocchi de; Barufaldi, Laura Augusta; Kuschnir, Maria Cristina Caetano; Szklo, Moyses; Montenegro, Renan; Silva, Thiago Luiz Nogueira da; Ekelund, Ulf; Schaan, Beatriz D

    2017-05-18

    The Study of Cardiovascular Risk in Adolescents (ERICA) is a pioneering study that aimed to assess the prevalence of cardiovascular risk factors, including metabolic syndrome components in Brazilian adolescents. This study aims to describe the methodological aspects related to blood collection as well as to report pertaining results of the preparation, transport, storage, and exams in ERICA. Exams in ERICA were performed in a single laboratory and blood samples were collected in schools in a standardized manner. Logistics involved air transportation of samples to the reference laboratory with controlled temperature since sample collection. The serum was stored in local biorepositories in four centers to be used in future analyses. During the study, 284,247 exams were performed and rate of participation in exams was 56.2%, thus involving 40,732 adolescents. From the total, 92.6% of the samples reached the reference laboratory maintaining the temperature between 0-10°C. No clinical significant changes in results due to temperature changes were identified. External quality control recorded satisfactory results in 98.7% of the evaluations. Four biorepositories with samples of 7,785 adolescents were created. Thus, we can consider that the logistics adopted in ERICA was fairly successful and description of this as well as the difficulties experienced in Brazil can inform and facilitate the planning of future studies, especially in developing countries.

  8. Analysis of Tank 13H (HTF-13-14-156, 157) Surface and Subsurface Supernatant Samples in Support of Enrichment Control, Corrosion Control and Sodium Aluminosilicate Formation Potential Programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oji, L. N.

    2015-02-18

    The 2H Evaporator system includes mainly Tank 43H (feed tank) and Tank 38H (drop tank) with Tank 22H acting as the DWPF recycle receipt tank. The Tank 13H is being characterized to ensure that it can be transferred to the 2H evaporator. This report provides the results of analyses on Tanks 13H surface and subsurface supernatant liquid samples to ensure compliance with the Enrichment Control Program (ECP), the Corrosion Control Program and Sodium Aluminosilicate Formation Potential in the Evaporator. The U-235 mass divided by the total uranium averaged 0.00799 (0.799 % uranium enrichment) for both the surface and subsurface Tankmore » 13H samples. This enrichment is slightly above the enrichment for Tanks 38H and 43H, where the enrichment normally ranges from 0.59 to 0.7 wt%. The U-235 concentration in Tank 13H samples ranged from 2.01E-02 to 2.63E-02 mg/L, while the U-238 concentration in Tank 13H ranged from 2.47E+00 to 3.21E+00 mg/L. Thus, the U-235/total uranium ratio is in line with the prior 2H-evaporator ECP samples. Measured sodium and silicon concentrations averaged, respectively, 2.46 M and 1.42E-04 M (3.98 mg/L) in the Tank 13H subsurface sample. The measured aluminum concentration in Tanks 13H subsurface samples averaged 2.01E-01 M.« less

  9. A Multirate Control Strategy to the Slow Sensors Problem: An Interactive Simulation Tool for Controller Assisted Design

    PubMed Central

    Salt, Julián; Cuenca, Ángel; Palau, Francisco; Dormido, Sebastián

    2014-01-01

    In many control applications, the sensor technology used for the measurement of the variable to be controlled is not able to maintain a restricted sampling period. In this context, the assumption of regular and uniform sampling pattern is questionable. Moreover, if the control action updating can be faster than the output measurement frequency in order to fulfill the proposed closed loop behavior, the solution is usually a multirate controller. There are some known aspects to be careful of when a multirate system (MR) is going to be designed. The proper multiplicity between input-output sampling periods, the proper controller structure, the existence of ripples and others issues need to be considered. A useful way to save time and achieve good results is to have an assisted computer design tool. An interactive simulation tool to deal with MR seems to be the right solution. In this paper this kind of simulation application is presented. It allows an easy understanding of the performance degrading or improvement when changing the multirate sampling pattern parameters. The tool was developed using Sysquake, a Matlab-like language with fast execution and powerful graphic facilities. It can be delivered as an executable. In the paper a detailed explanation of MR treatment is also included and the design of four different MR controllers with flexible structure to be adapted to different schemes will also be presented. The Smith's predictor in these MR schemes is also explained, justified and used when time delays appear. Finally some interesting observations achieved using this interactive tool are included. PMID:24583971

  10. Application of a nanotechnology antimicrobial spray to prevent lower urinary tract infection: a multicenter urology trial

    PubMed Central

    2012-01-01

    Background Catheter-associated urinary tract infection (CAUTI) is a common nosocomial device-associated infection. It is now recognized that the high infection rates were caused by the formation of biofilm on the surface of the catheters that decreases the susceptibility to antibiotics and results in anti-microbial resistance. In this study, we performed an in vitro test to explore the mechanism of biofilm formation and subsequently conducted a multi-center clinical trial to investigate the efficacy of CAUTI prevention with the application of JUC, a nanotechnology antimicrobial spray. Methods Siliconized latex urinary catheters were cut into fragments and sterilized by autoclaving. The sterilized sample fragments were randomly divided into the therapy and control group, whereby they were sprayed with JUC and distilled water respectively and dried before use. The experimental standard strains of Escherichia coli (E. coli) were isolated from the urine samples of patients. At 16 hours and 7 days of incubation, the samples were extracted for confocal laser scanning microscopy. A total of 1,150 patients were accrued in the clinical study. Patients were randomized according to the order of surgical treatment. The odd array of patients was assigned as the therapy group (JUC), and the even array of patients was assigned as the control group (normal saline). Results After 16 hours of culture, bacterial biofilm formed on the surface of sample fragments from the control group. In the therapy group, no bacterial biofilm formation was observed on the sample fragments. No significant increase in bacterial colony count was observed in the therapy group after 7 days of incubation. On the 7th day of catheterization, urine samples were collected for bacterial culture before extubation. Significant difference was observed in the incidence of bacteriuria between the therapy group and control group (4.52% vs. 13.04%, p < 0.001). Conclusions In this study, the effectiveness of JUC in preventing CAUTI in a hospital setting was demonstrated in both in vitro and clinical studies. PMID:23046566

  11. Adaptive Peer Sampling with Newscast

    NASA Astrophysics Data System (ADS)

    Tölgyesi, Norbert; Jelasity, Márk

    The peer sampling service is a middleware service that provides random samples from a large decentralized network to support gossip-based applications such as multicast, data aggregation and overlay topology management. Lightweight gossip-based implementations of the peer sampling service have been shown to provide good quality random sampling while also being extremely robust to many failure scenarios, including node churn and catastrophic failure. We identify two problems with these approaches. The first problem is related to message drop failures: if a node experiences a higher-than-average message drop rate then the probability of sampling this node in the network will decrease. The second problem is that the application layer at different nodes might request random samples at very different rates which can result in very poor random sampling especially at nodes with high request rates. We propose solutions for both problems. We focus on Newscast, a robust implementation of the peer sampling service. Our solution is based on simple extensions of the protocol and an adaptive self-control mechanism for its parameters, namely—without involving failure detectors—nodes passively monitor local protocol events using them as feedback for a local control loop for self-tuning the protocol parameters. The proposed solution is evaluated by simulation experiments.

  12. Disposable collection kit for rapid and reliable collection of saliva.

    PubMed

    Yamaguchi, Masaki; Tezuka, Yuki; Takeda, Kazunori; Shetty, Vivek

    2015-01-01

    To describe and evaluate disposable saliva collection kit for rapid, reliable, and reproducible collection of saliva samples. The saliva collection kit comprised of a saliva absorbent swab and an extractor unit was used to retrieve whole saliva samples from 10 subjects. The accuracy and precision of the extracted volumes (3, 10, and 30 μl) were compared to similar volumes drawn from control samples obtained by passive drool. Additionally, the impact of kit collection method on subsequent immunoassay results was verified by assessing salivary cortisol levels in the samples and comparing them to controls. The recovered volumes for the whole saliva samples were 3.85 ± 0.28, 10.79 ± 0.95, and 31.18 ± 1.72 μl, respectively (CV = 8.76%) and 2.91 ± 0.19, 9.75 ± 0.43, and 29.64 ± 0.91 μl, respectively, (CV = 6.36%) for the controls. There was a close correspondence between the salivary cortisol levels from the saliva samples obtained by the collection kit and the controls (R(2)  > 0.96). The disposable saliva collection kit allows accurate and repeatable collection of fixed amounts of whole saliva and does not interfere with subsequent measurements of salivary cortisol. The simple collection process, lack of elaborate specimen recovery steps, and the short turnaround time (<3 min) should render the kit attractive to test subjects and researchers alike. © 2015 Wiley Periodicals, Inc.

  13. Re-emergence of rabies virus maintained by canid populations in Paraguay.

    PubMed

    Amarilla, A C F; Pompei, J C A; Araujo, D B; Vázquez, F A; Galeano, R R; Delgado, L M; Bogado, G; Colman, M; Sanabria, L; Iamamoto, K; Garcia, R; Assis, D; Recalde, R; Martorelli, L F; Quiñones, E; Cabello, A; Martini, M; Cosivi, O; Durigon, E L; Favoretto, S R

    2018-02-01

    Paraguay has registered no human cases of rabies since 2004, and the last case in dogs, reported in 2009, was due to a variant maintained in the common vampire bat "Desmodus rotundus". In 2014, a dog was diagnosed as positive for rabies with aggression towards a boy and all required measures of control were successfully adopted. Epidemiological investigation revealed that the dog was not vaccinated and had been attacked by a crab-eating fox, "zorro" (Cerdocyon thous). The sample was diagnosed by the Official Veterinary Service of the Country and sent to the Center on Rabies Research from the University of São Paulo, Brazil, for antigenic and genetic characterization. A second sample from a dog positive for rabies in the same region in 2015 and 11 samples from a rabies outbreak from Asuncion in 1996 were also characterized. The antigenic profile of the samples, AgV2, was compatible with one of the variants maintained by dogs in Latin America. In genetic characterization, the samples segregated in the canine (domestic and wild species)-related group in an independent subgroup that also included samples from Argentina. These results and the epidemiology of the case indicate that even with the control of rabies in domestic animals, the virus can still circulate in wildlife and may be transmitted to domestic animals and humans, demonstrating the importance of continuous and improved surveillance and control of rabies, including in wild species, to prevent outbreaks in controlled areas. © 2017 Blackwell Verlag GmbH.

  14. Analysis of ground water by different laboratories: a comparison of chloride and nitrate data, Nassau and Suffolk counties, New York

    USGS Publications Warehouse

    Katz, Brian G.; Krulikas, Richard K.

    1979-01-01

    Water samples from wells in Nassau and Suffolk Counties were analyzed for chloride and nitrate. Two samples were collected at each well; one was analyzed by the U.S. Geological Survey, the other by a laboratory in the county from which the sample was taken. Results were compared statistically by paired-sample t-test to indicate the degree of uniformity among laboratory results. Chloride analyses from one of the three county laboratories differed significantly (0.95 confidence level) from that of a Geological Survey laboratory. For nitrate analyses, a significant difference (0.95 confidence level) was noted between results from two of the three county laboratories and the Geological Survey laboratory. The lack of uniformity among results reported by the participating laboratories indicates a need for continuing participation in a quality-assurance program and exercise of strong quality control from time of sample collection through analysis so that differences can be evaluated. (Kosco-USGS)

  15. The use of isotypic control antibodies in the analysis of CD3+ and CD3+, CD4+ lymphocyte subsets by flow cytometry. Are they really necessary?

    PubMed

    Sreenan, J J; Tbakhi, A; Edinger, M G; Tubbs, R R

    1997-02-01

    Isotypic control reagents are defined as irrelevant antibodies of the same immunoglobulin class as the relevant reagent antibody in a flow cytometry panel. The use of the isotypic control antibody has been advocated as a necessary quality control measure in analysis of flow cytometry. The purpose of this study was to determine the necessity of an isotypic control antibody in the analysis of CD3+ and CD3+, CD4+ lymphocyte subsets. We performed a prospective study of 46 consecutive patient samples received for lymphocyte subset analysis to determine the need for the isotypic control. For each sample, a sham buffer (autocontrol) and isotypic control reagent were stained for three-color immunofluorescence, processed, and identically analyzed with Attractors software. The Attractors software allowed independent, multiparametric, simultaneous gating; was able to identically and reproducibly process each list mode file; and yielded population data in spreadsheet form. Statistical analysis (Fisher's z test) revealed no difference between the CD3+ autocontrol and CD3+ isotypic control (correlation = 1, P < .0001) or between the CD3+, CD4+ autocontrol and the CD3+, CD4+ isotypic control (correlation = 1, P < .0001). The elimination of the isotypic control reagent resulted in a total cost savings of $3.36 per test. Additionally, the subtraction of isotypic background can artifactually depress population enumeration. The use of an isotypic control antibody is not necessary to analyze flow cytometric data that result in discrete cell populations, such as CD3+ and CD3+, CD4+ lymphocyte subsets. The elimination of this unnecessary quality control measure results in substantial cost savings.

  16. An uncooked vegan diet shifts the profile of human fecal microflora: computerized analysis of direct stool sample gas-liquid chromatography profiles of bacterial cellular fatty acids.

    PubMed Central

    Peltonen, R; Ling, W H; Hänninen, O; Eerola, E

    1992-01-01

    The effect of an uncooked extreme vegan diet on fecal microflora was studied by direct stool sample gas-liquid chromatography (GLC) of bacterial cellular fatty acids and by quantitative bacterial culture by using classical microbiological techniques of isolation, identification, and enumeration of different bacterial species. Eighteen volunteers were divided randomly into two groups. The test group received an uncooked vegan diet for 1 month and a conventional diet of mixed Western type for the other month of the study. The control group consumed a conventional diet throughout the study period. Stool samples were collected. Bacterial cellular fatty acids were extracted directly from the stool samples and measured by GLC. Computerized analysis of the resulting fatty acid profiles was performed. Such a profile represents all bacterial cellular fatty acids in a sample and thus reflects its microflora and can be used to detect changes, differences, or similarities of bacterial flora between individual samples or sample groups. GLC profiles changed significantly in the test group after the induction and discontinuation of the vegan diet but not in the control group at any time, whereas quantitative bacterial culture did not detect any significant change in fecal bacteriology in either of the groups. The results suggest that an uncooked extreme vegan diet alters the fecal bacterial flora significantly when it is measured by direct stool sample GLC of bacterial fatty acids. PMID:1482187

  17. Prevalence of doping in sports: doping control in Norway, 1977-1995.

    PubMed

    Bahr, R; Tjørnhom, M

    1998-01-01

    To examine the results from doping controls conducted by the Norwegian Confederation of Sport (NCS) from 1977 to 1995. Data were collected by combining three computerized databases and manual records on samples taken and results from analyses in the International Olympic Committee (IOC)-accredited laboratories in London, Huddinge, Cologne, and Oslo. Samples were declared positive if they contained any banned substance on the IOC list that was in effect at any given time. A total of 15,208 samples were taken; most of them (12,870; 85%) were from Norwegian athletes (90% unannounced tests) belonging to national federations under NCS jurisdiction (NCS members), 461 (3%) were from external Norwegian athletes (either users of private gyms or athletes in organized sports federations not affiliated with the NCS), and 1,874 (12%) were from foreign athletes (three cases with unknown affiliation). There were 130 positive samples and 24 refusals among NCS members (1.2%; men, 1.4%; women, 0.3%), 86 positive samples and 8 refusals among external Norwegian athletes (20%; men, 24%; women, 8%), and 39 positive samples and 1 refusal among foreign athletes (1.6%; men, 2.1%; women, 0.7%). A gradual decrease in the percentage of positive samples was observed among NCS members as testing frequency was increased gradually from 1987 to 1995 in the three high-prevalence sports: powerlifting, weightlifting, and athletics. An increase in the test frequency of doping tests was associated with a decrease in the percentage of positive samples in targeted sports.

  18. Toxicological Assessment of ISS Air Quality: April - May 2013. [Increment 35

    NASA Technical Reports Server (NTRS)

    Meyers, Valerie

    2013-01-01

    A summary of the analytical results from 4 mini-grab sample (mGSCs) collected on ISS and returned aboard 33S is shown in Table 1. Due to the launch delay of the ATV4 resupply mission, monthly samples were reduced in April and May by omitting sampling of the Service Module in order to ensure contingency samplers were available if needed. Complete data tables of all measured concentrations and corresponding T-values based on 180-day SMACs are enclosed. detection limit for all target compounds, except m/p-xylenes and hexachloro-1, 3-butadiene was 0.025 mg/cu m. The detection limit for m/p-xylenes and hexachloro-1, 3-butadiene and all non-target compounds was 0.05 mg/cu m. The average recoveries of the 3 surrogate standards from the mGSCs were as follows: C-13-acetone, 116 +/- 12%; D-5-fluorobenzene, 117 +/- 7%; and D-5-chlorobenzene, 111 +/- 15%. Initial measured sample pressures were between 13.9 and 14.1 psia for all samples, indicating nominal sample collection. A summary of the analytical results from 3 pairs of passive-diffusion formaldehyde badges collected on ISS and returned aboard 33S is also provided in Table 1. In an effort to conserve samples due to the delay of the ATV4 resupply mission, FMK sampling was only conducted in the US Lab in May. Positive control recoveries (1 trip and 2 lab controls) were 79%, 87%, and 116% respectively.

  19. Chemical characterization of outdoor and subway fine (PM(2.5-1.0)) and coarse (PM(10-2.5)) particulate matter in Seoul (Korea) by computer-controlled scanning electron microscopy (CCSEM).

    PubMed

    Byeon, Sang-Hoon; Willis, Robert; Peters, Thomas M

    2015-02-13

    Outdoor and indoor (subway) samples were collected by passive sampling in urban Seoul (Korea) and analyzed with computer-controlled scanning electron microscopy coupled with energy dispersive x-ray spectroscopy (CCSEM-EDX). Soil/road dust particles accounted for 42%-60% (by weight) of fine particulate matter larger than 1 µm (PM(2.5-1.0)) in outdoor samples and 18% of PM2.5-1.0 in subway samples. Iron-containing particles accounted for only 3%-6% in outdoor samples but 69% in subway samples. Qualitatively similar results were found for coarse particulate matter (PM(10-2.5)) with soil/road dust particles dominating outdoor samples (66%-83%) and iron-containing particles contributing most to subway PM(10-2.5) (44%). As expected, soil/road dust particles comprised a greater mass fraction of PM(10-2.5) than PM(2.5-1.0). Also as expected, the mass fraction of iron-containing particles was substantially less in PM(10-2.5) than in PM(2.5-1.0). Results of this study are consistent with known emission sources in the area and with previous studies, which showed high concentrations of iron-containing particles in the subway compared to outdoor sites. Thus, passive sampling with CCSEM-EDX offers an inexpensive means to assess PM(2.5-1.0) and PM(10-2.5) simultaneously and by composition at multiple locations.

  20. Control of Rydberg atom blockade by dc electric field orientation in a quasi-one-dimensional sample

    NASA Astrophysics Data System (ADS)

    Goncalves, Luís Felipe; Marcassa, Luis Gustavo

    2017-04-01

    Rydberg atoms posse a strong atom-atom interaction, which limits its density in an atomic sample. Such effect is known as Rydberg atom blockade. Here, we present a novel way to control such effect by direct orienting the induced atomic dipole moment using a dc external electrical field. To demonstrate it, we excite the 50S1 / 2 Rb atomic state in a quasi-one-dimensional sample held in a quasi-electrostatic trap. A pure nS state holds only van der Waals interaction at long range, but in the presence of an external electric field the state mixing leads to strong dipole-dipole interactions. We have measured the Rydberg atom population as a function of ground state atoms density for several angles between the electric field and the main axis of the unidimensional sample. The results indicate that the limit on the final Rydberg density can be controlled by electric field orientation. Besides, we have characterized the sample by using direct spatial ion imaging, demonstrating that it does behave as an unidimensional sample. This work was supported by Sao Paulo Research Foundation (FAPESP) Grants No. 2011/22309-8 and No. 2013/02816- 8, the U.S. Army Research Office Grant No. W911NF-15-1-0638 and CNPq.

  1. The effect of Cinnamomum zeylanicum essential oil on chemical characteristics of Lyoner- type sausage during refrigerated storage

    PubMed Central

    Aminzare, Majid; Aliakbarlu, Javad; Tajik, Hossein

    2015-01-01

    The effect of Cinnamomum zeylanicum essential oil (CZEO) at two concentrations (0.02% and 0.04% v/w) on chemical composition, pH, water activity (aw), lipid oxidation, color stability and sensory characteristics of Lyoner-type sausage stored at 4 ˚C for 40 days was investigated. The moisture content of the control sample was higher (p < 0.05) than CZEO incorporated samples, while fat, ash and protein content were not affected by adding essential oil. At days 0 and 40, Lightness (L*) and whiteness index (WI) were significantly decreased and total color difference (ΔE) significantly increased (p < 0.05) by adding CZEO. With the exception of first day of storage, redness (a*) and yellowness (b*) were significantly increased and decreased, respectively during the rest of storage (p < 0.05). The pH values were not differing between the control samples and samples containing CZEO (p > 0.05). The water activity content fell in Lyoners with added CZEO during the storage. Incorporation of CZEO retard lipid oxidation process at the end of storage (p < 0.05). Samples containing highest amount of CZEO had higher sensory score compared to control sample. Our results pointed out that CZEO could be used as natural additive for increasing the chemical stability of Lyoner-type sausages. PMID:25992249

  2. How a routine checking of Escherichia coli in retailed food of animal origin can protect consumers against exposition to Campylobacter spp. and Listeria monocytogenes?

    PubMed

    Trajković-Pavlović, Ljiljana; Novaković, Budimka; Martinov-Cvejin, Mirjana; Gusman, Vera; Bijelović, Sanja; Dragnić, Natasa; Balać, Dragana

    2010-08-01

    According to the literature that has been published over the last two decades Campylobacter spp i Listeria monocitogens can be identified as causes of numerous diseases derived by consuming food of animal origin. The purpose of this paper was to find out how established national microbiological criteria of the Republic of Serbia on food safety in retailed food of animal origin could contribute to consumer's protection against exposition to foodborne pathogens such as Campylobacter spp. and Listeria monocytogenes. During a routine microbiological safety control of randomly selected 60 samples of fresh poultry meat, 30 samples of other fresh meat readymade for grilling, 30 samples of sausage products, 37 samples of heat-treated meat, 39 samples of toppings for fast food of animal origin and 31 samples of dairy products a national food safety criteria (Escherichia coli, aerobic plate count, Salmonella spp., coagulasa positive Staphylococcus, Proteus spp., sulphito-reducting Clostridia) were applied and, as well as, testing to Campylobacter spp. and Listeria monocitogens. In determination of Campylobacter spp. and Listeria monocytogenes, food quality control methods of the Food and Agriculture Organization (FAO) were applied, while in determination of the other above motioned bacteria, national provisions on microbiological methods were applied who are adjusted to the FAO ones. Related to the national criteria on microbiological food safety, 88 (38.8%) samples, out of the total 227 tested, were rejected. When to these results, the results of laboratory tests on Listeria monocytogens were added, a terminal number of rejected samples were not changed. When to these results, the results of Campylobacter spp. testing were added, 91 (40.1%) out of the 227 samples were unsatisfied. Results of logistic regression model with occurrence of Escherichia coli as dependent variable indicated that Escherichia coli was 4.5 times likely to occur among samples with Campylobacter spp. than among samples without Campylobacter spp. (OR = 4.515, 95% CI: 1.019-20.002). Sensitivity of the fitted model (Hosmer-Lemeshowp = 0.268) was 76.8% and its specificity was 75.0%. At the same time Escherichia coli was confound in all (100%) food samples that were contaminated by Listeria monocytogenes. Statistical analysis indicated that Escherichia coli was completely sensitive to identify all samples contaminated with Listeria monocytogenas and highly sensitive to identify samples contaminated with Campylobacter spp. Nevertheless, 3 (1.3%) of the tested samples were not covered with Escherichia coli.

  3. Genetic Stability of Streptomyces Lividans pIJ702 in Response to Spaceflight

    NASA Astrophysics Data System (ADS)

    Lim, K. S.; Goins, T. L.; Voeikova, T. A.; Pyle, B. H.

    2008-06-01

    Streptomyces lividans carrying plasmid pIJ702 encoding genes for thiostrepton resistance (tsr-) and melanin production (mel+) was plated on agar and flown on the Russian satellite Foton-M3 for 16 days. The percentage loss of plasmid expression in flight samples was lower than that in ground samples when both samples were grown in enriched (ISP) media. Differences in media content also affect plasmid expression rate; ISP media have a higher loss of plasmid expression than samples in minimum media when both were grown on ground conditions. Results suggest that stress resulted in the increased expression of plasmid pIJ702 by S. lividans. Screening of thiostrepton resistant white (tsr+ mel-) mutants showed similar proportions of variants in ground samples and flight samples. To determine if there are mutations in the mel gene, DNA extracted from flight and control white mutants was amplified and gel electrophoresis of amplified products show no major mutation in the products. Sequencing of amplified products is required to identify mutations resulting in loss of pigmentation.

  4. Study protocol of the CHOiCE trial: a three-armed, randomized, controlled trial of home-based HPV self-sampling for non-participants in an organized cervical cancer screening program.

    PubMed

    Tranberg, Mette; Bech, Bodil Hammer; Blaakær, Jan; Jensen, Jørgen Skov; Svanholm, Hans; Andersen, Berit

    2016-11-03

    The effectiveness of cervical cancer screening programs is challenged by suboptimal participation and coverage. Offering cervico-vaginal self-sampling for human papillomavirus testing (HPV self-sampling) to non-participants can increase screening participation. However, the effect varies substantially among studies, especially depending on the approach used to offer HPV self-sampling. The present trial evaluates the effect on participation in an organized screening program of a HPV self-sampling kit mailed directly to the home of the woman or mailed to the woman's home on demand only, compared with the standard second reminder for regular screening. The CHOiCE trial is a parallel, randomized, controlled, open-label trial. It will include 9327 women aged 30-64 years who are living in the Central Denmark Region and who have not participated in cervical cancer screening after an invitation and one reminder. The women will be equally randomized into three arms: 1) Directly mailed a second reminder including a HPV self-sampling kit; 2) Mailed a second reminder offering a HPV self-sampling kit, to be ordered by e-mail, text message, phone, or through a webpage; and 3) Mailed a second reminder for a practitioner-collected sample (control group). The primary outcome will be the proportion of women in the intervention groups who participate by returning their HPV self-sampling kit or have a practitioner-collected sample compared with the proportion of women who have a practitioner-collected sample in the control group at 90 and 180 days after mail out of the second reminders. Per-protocol and intention-to-treat analyses will be performed. The secondary outcome will be the proportion of women with a positive HPV self-collected sample who attend follow-up testing at 30, 60, or 90 days after mail out of the results. The CHOiCE trial will provide strong and important evidence allowing us to determine if and how HPV self-sampling can be used to increase participation in cervical cancer screening. This trial therefore has the potential to improve prevention and reduce the number of deaths caused by cervical cancer. Current Controlled Trials NCT02680262 . Registered 10 February 2016.

  5. QCScreen: a software tool for data quality control in LC-HRMS based metabolomics.

    PubMed

    Simader, Alexandra Maria; Kluger, Bernhard; Neumann, Nora Katharina Nicole; Bueschl, Christoph; Lemmens, Marc; Lirk, Gerald; Krska, Rudolf; Schuhmacher, Rainer

    2015-10-24

    Metabolomics experiments often comprise large numbers of biological samples resulting in huge amounts of data. This data needs to be inspected for plausibility before data evaluation to detect putative sources of error e.g. retention time or mass accuracy shifts. Especially in liquid chromatography-high resolution mass spectrometry (LC-HRMS) based metabolomics research, proper quality control checks (e.g. for precision, signal drifts or offsets) are crucial prerequisites to achieve reliable and comparable results within and across experimental measurement sequences. Software tools can support this process. The software tool QCScreen was developed to offer a quick and easy data quality check of LC-HRMS derived data. It allows a flexible investigation and comparison of basic quality-related parameters within user-defined target features and the possibility to automatically evaluate multiple sample types within or across different measurement sequences in a short time. It offers a user-friendly interface that allows an easy selection of processing steps and parameter settings. The generated results include a coloured overview plot of data quality across all analysed samples and targets and, in addition, detailed illustrations of the stability and precision of the chromatographic separation, the mass accuracy and the detector sensitivity. The use of QCScreen is demonstrated with experimental data from metabolomics experiments using selected standard compounds in pure solvent. The application of the software identified problematic features, samples and analytical parameters and suggested which data files or compounds required closer manual inspection. QCScreen is an open source software tool which provides a useful basis for assessing the suitability of LC-HRMS data prior to time consuming, detailed data processing and subsequent statistical analysis. It accepts the generic mzXML format and thus can be used with many different LC-HRMS platforms to process both multiple quality control sample types as well as experimental samples in one or more measurement sequences.

  6. Thin magnesium layer confirmed as an antibacterial and biocompatible implant coating in a co‑culture model.

    PubMed

    Zaatreh, Sarah; Haffner, David; Strauss, Madlen; Dauben, Thomas; Zamponi, Christiane; Mittelmeier, Wolfram; Quandt, Eckhard; Kreikemeyer, Bernd; Bader, Rainer

    2017-04-01

    Implant-associated infections commonly result from biofilm‑forming bacteria and present severe complications in total joint arthroplasty. Therefore, there is a requirement for the development of biocompatible implant surfaces that prevent bacterial biofilm formation. The present study coated titanium samples with a thin, rapidly corroding layer of magnesium, which were subsequently investigated with respect to their antibacterial and cytotoxic surface properties using a Staphylococcus epidermidis (S. epidermidis) and human osteoblast (hOB) co‑culture model. Primary hOBs and S. epidermidis were co‑cultured on cylindrical titanium samples (Ti6Al4V) coated with pure magnesium via magnetron sputtering (5 µm thickness) for 7 days. Uncoated titanium test samples served as controls. Vital hOBs were identified by trypan blue staining at days 2 and 7. Planktonic S. epidermidis were quantified by counting the number of colony forming units (CFU). The quantification of biofilm‑bound S. epidermidis on the surfaces of test samples was performed by ultrasonic treatment and CFU counting at days 2 and 7. The number of planktonic and biofilm‑bound S. epidermidis on the magnesium‑coated samples decreased by four orders of magnitude when compared with the titanium control following 7 days of co‑culture. The number of vital hOBs on the magnesium‑coated samples was observed to increase (40,000 cells/ml) when compared with the controls (20,000 cells/ml). The results of the present study indicate that rapidly corroding magnesium‑coated titanium may be a viable coating material that possesses antibacterial and biocompatible properties. A co‑culture test is more rigorous than a monoculture study, as it accounts for confounding effects and assesses additional interactions that are more representative of in vivo situations. These results provide a foundation for the future testing of this type of surface in animals.

  7. Thin magnesium layer confirmed as an antibacterial and biocompatible implant coating in a co-culture model

    PubMed Central

    Zaatreh, Sarah; Haffner, David; Strauss, Madlen; Dauben, Thomas; Zamponi, Christiane; Mittelmeier, Wolfram; Quandt, Eckhard; Kreikemeyer, Bernd; Bader, Rainer

    2017-01-01

    Implant-associated infections commonly result from biofilm-forming bacteria and present severe complications in total joint arthroplasty. Therefore, there is a requirement for the development of biocompatible implant surfaces that prevent bacterial biofilm formation. The present study coated titanium samples with a thin, rapidly corroding layer of magnesium, which were subsequently investigated with respect to their antibacterial and cytotoxic surface properties using a Staphylococcus epidermidis (S. epidermidis) and human osteoblast (hOB) co-culture model. Primary hOBs and S. epidermidis were co-cultured on cylindrical titanium samples (Ti6Al4V) coated with pure magnesium via magnetron sputtering (5 µm thickness) for 7 days. Uncoated titanium test samples served as controls. Vital hOBs were identified by trypan blue staining at days 2 and 7. Planktonic S. epidermidis were quantified by counting the number of colony forming units (CFU). The quantification of biofilm-bound S. epidermidis on the surfaces of test samples was performed by ultrasonic treatment and CFU counting at days 2 and 7. The number of planktonic and biofilm-bound S. epidermidis on the magnesium-coated samples decreased by four orders of magnitude when compared with the titanium control following 7 days of co-culture. The number of vital hOBs on the magnesium-coated samples was observed to increase (40,000 cells/ml) when compared with the controls (20,000 cells/ml). The results of the present study indicate that rapidly corroding magnesium-coated titanium may be a viable coating material that possesses antibacterial and biocompatible properties. A co-culture test is more rigorous than a monoculture study, as it accounts for confounding effects and assesses additional interactions that are more representative of in vivo situations. These results provide a foundation for the future testing of this type of surface in animals. PMID:28260022

  8. Clinical Assessment of a Nocardia PCR-Based Assay for Diagnosis of Nocardiosis.

    PubMed

    Rouzaud, Claire; Rodriguez-Nava, Véronica; Catherinot, Emilie; Méchaï, Frédéric; Bergeron, Emmanuelle; Farfour, Eric; Scemla, Anne; Poirée, Sylvain; Delavaud, Christophe; Mathieu, Daniel; Durupt, Stéphane; Larosa, Fabrice; Lengelé, Jean-Philippe; Christophe, Jean-Louis; Suarez, Felipe; Lortholary, Olivier; Lebeaux, David

    2018-06-01

    The diagnosis of nocardiosis, a severe opportunistic infection, is challenging. We assessed the specificity and sensitivity of a 16S rRNA Nocardia PCR-based assay performed on clinical samples. In this multicenter study (January 2014 to April 2015), patients who were admitted to three hospitals and had an underlying condition favoring nocardiosis, clinical and radiological signs consistent with nocardiosis, and a Nocardia PCR assay result for a clinical sample were included. Patients were classified as negative control (NC) (negative Nocardia culture results and proven alternative diagnosis or improvement at 6 months without anti- Nocardia treatment), positive control (PC) (positive Nocardia culture results), or probable nocardiosis (positive Nocardia PCR results, negative Nocardia culture results, and no alternative diagnosis). Sixty-eight patients were included; 47 were classified as NC, 8 as PC, and 13 as probable nocardiosis. PCR results were negative for 35/47 NC patients (74%). For the 12 NC patients with positive PCR results, the PCR assay had been performed with respiratory samples. These NC patients had chronic bronchopulmonary disease more frequently than did the NC patients with negative PCR results (8/12 patients [67%] versus 11/35 patients [31%]; P = 0.044). PCR results were positive for 7/8 PC patients (88%). There were 13 cases of probable nocardiosis, diagnosed solely using the PCR results; 9 of those patients (69%) had lung involvement (consolidation or nodule). Nocardia PCR testing had a specificity of 74% and a sensitivity of 88% for the diagnosis of nocardiosis. Nocardia PCR testing may be helpful for the diagnosis of nocardiosis in immunocompromised patients but interpretation of PCR results from respiratory samples is difficult, because the PCR assay may also detect colonization. Copyright © 2018 American Society for Microbiology.

  9. Association of a common interferon regulatory factor 5 (IRF5) variant with increased risk of systemic lupus erythematosus (SLE).

    PubMed

    Demirci, F Y K; Manzi, S; Ramsey-Goldman, R; Minster, R L; Kenney, M; Shaw, P S; Dunlop-Thomas, C M; Kao, A H; Rhew, E; Bontempo, F; Kammerer, C; Kamboh, M I

    2007-05-01

    Interferon regulatory factor 5 (IRF5) belongs to a family of transcription factors that control the transactivation of type I interferon system-related genes, as well as the expression of several other genes involved in immune response, cell signalling, cell cycle control and apoptosis. Two recent studies reported a significant association between the IRF5/rs2004640 T allele and systemic lupus erythematosus (SLE). The purpose of this study was to determine whether the reported rs2004640 T allele association could be replicated in our independent SLE case-control sample. We genotyped DNA samples from 370 white SLE-affected female subjects and 462 white healthy female controls using the TaqMan Assay-on-Demand for rs2004640, and performed a case-control genetic association analysis. Frequency of the rs2004640 T allele was significantly higher in cases than in controls (56.5% vs. 50%; P= 0.008). The odds ratio for T allele carriers was 1.68 (95% CI: 1.20 - 2.34; P= 0.003). Our results in an independent case-control sample confirm the robust association of the IRF5/rs2004640 T allele with SLE risk, and further support the relevance of the type I interferon system in the pathogenesis of SLE and autoimmunity.

  10. Adaptive control of turbulence intensity is accelerated by frugal flow sampling.

    PubMed

    Quinn, Daniel B; van Halder, Yous; Lentink, David

    2017-11-01

    The aerodynamic performance of vehicles and animals, as well as the productivity of turbines and energy harvesters, depends on the turbulence intensity of the incoming flow. Previous studies have pointed at the potential benefits of active closed-loop turbulence control. However, it is unclear what the minimal sensory and algorithmic requirements are for realizing this control. Here we show that very low-bandwidth anemometers record sufficient information for an adaptive control algorithm to converge quickly. Our online Newton-Raphson algorithm tunes the turbulence in a recirculating wind tunnel by taking readings from an anemometer in the test section. After starting at 9% turbulence intensity, the algorithm converges on values ranging from 10% to 45% in less than 12 iterations within 1% accuracy. By down-sampling our measurements, we show that very-low-bandwidth anemometers record sufficient information for convergence. Furthermore, down-sampling accelerates convergence by smoothing gradients in turbulence intensity. Our results explain why low-bandwidth anemometers in engineering and mechanoreceptors in biology may be sufficient for adaptive control of turbulence intensity. Finally, our analysis suggests that, if certain turbulent eddy sizes are more important to control than others, frugal adaptive control schemes can be particularly computationally effective for improving performance. © 2017 The Author(s).

  11. Identification of Hot Moments and Hot Spots for Real-Time Adaptive Control of Multi-scale Environmental Sensor Networks

    NASA Astrophysics Data System (ADS)

    Wietsma, T.; Minsker, B. S.

    2012-12-01

    Increased sensor throughput combined with decreasing hardware costs has led to a disruptive growth in data volume. This disruption, popularly termed "the data deluge," has placed new demands for cyberinfrastructure and information technology skills among researchers in many academic fields, including the environmental sciences. Adaptive sampling has been well established as an effective means of improving network resource efficiency (energy, bandwidth) without sacrificing sample set quality relative to traditional uniform sampling. However, using adaptive sampling for the explicit purpose of improving resolution over events -- situations displaying intermittent dynamics and unique hydrogeological signatures -- is relatively new. In this paper, we define hot spots and hot moments in terms of sensor signal activity as measured through discrete Fourier analysis. Following this frequency-based approach, we apply the Nyquist-Shannon sampling theorem, a fundamental contribution from signal processing that led to the field of information theory, for analysis of uni- and multivariate environmental signal data. In the scope of multi-scale environmental sensor networks, we present several sampling control algorithms, derived from the Nyquist-Shannon theorem, that operate at local (field sensor), regional (base station for aggregation of field sensor data), and global (Cloud-based, computationally intensive models) scales. Evaluated over soil moisture data, results indicate significantly greater sample density during precipitation events while reducing overall sample volume. Using these algorithms as indicators rather than control mechanisms, we also discuss opportunities for spatio-temporal modeling as a tool for planning/modifying sensor network deployments. Locally adaptive model based on Nyquist-Shannon sampling theorem Pareto frontiers for local, regional, and global models relative to uniform sampling. Objectives are (1) overall sampling efficiency and (2) sampling efficiency during hot moments as identified using heuristic approach.

  12. Rationale and design of the HOME trial: A pragmatic randomized controlled trial of home-based human papillomavirus (HPV) self-sampling for increasing cervical cancer screening uptake and effectiveness in a U.S. healthcare system.

    PubMed

    Winer, Rachel L; Tiro, Jasmin A; Miglioretti, Diana L; Thayer, Chris; Beatty, Tara; Lin, John; Gao, Hongyuan; Kimbel, Kilian; Buist, Diana S M

    2018-01-01

    Women who delay or do not attend Papanicolaou (Pap) screening are at increased risk for cervical cancer. Trials in countries with organized screening programs have demonstrated that mailing high-risk (hr) human papillomavirus (HPV) self-sampling kits to under-screened women increases participation, but U.S. data are lacking. HOME is a pragmatic randomized controlled trial set within a U.S. integrated healthcare delivery system to compare two programmatic approaches for increasing cervical cancer screening uptake and effectiveness in under-screened women (≥3.4years since last Pap) aged 30-64years: 1) usual care (annual patient reminders and ad hoc outreach by clinics) and 2) usual care plus mailed hrHPV self-screening kits. Over 2.5years, eligible women were identified through electronic medical record (EMR) data and randomized 1:1 to the intervention or control arm. Women in the intervention arm were mailed kits with pre-paid envelopes to return samples to the central clinical laboratory for hrHPV testing. Results were documented in the EMR to notify women's primary care providers of appropriate follow-up. Primary outcomes are detection and treatment of cervical neoplasia. Secondary outcomes are cervical cancer screening uptake, abnormal screening results, and women's experiences and attitudes towards hrHPV self-sampling and follow-up of hrHPV-positive results (measured through surveys and interviews). The trial was designed to evaluate whether a programmatic strategy incorporating hrHPV self-sampling is effective in promoting adherence to the complete screening process (including follow-up of abnormal screening results and treatment). The objective of this report is to describe the rationale and design of this pragmatic trial. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Effect of Environmental and Behavioral Interventions on Pain Intensity in Preterm Infants for Heel Prick Blood Sampling in the Neonatal Intensive Care Unit.

    PubMed

    Baharlooei, Fatemeh; Marofi, Maryam; Abdeyazdan, Zahra

    2017-01-01

    Recent researches suggest that preterm infants understand pain and stress. Because of the wide range of effects of pain on infants, the present study was conducted on the effect of environmental and behavioral interventions on pain due to heel-prick blood sampling in preterm infants. A clinical trial was conducted among 32 infants with gestational age of 32-37 weeks in the intervention and control groups. The effects of noise reduction by earplugs, light reduction by blindfolds, reduction of nursing manipulation, and creation of intrauterine position for neonates, 30 minutes before taking blood samples until 30 minutes after it, were measured during the intervention stage. Data were collected using the Neonatal Infant Pain Scale (NIPS) in 5 stages (before intervention, 2 minutes before sampling, during the sampling, and 5 minutes and 30 minutes after the sampling). The data were analyzed using analysis of variance (ANOVA) and paired t -test in SPSS software. The paired t -test results showed no significant differences between the control and intervention stages in terms of pain scores at base time ( P = 0.42) and 2 minutes before sampling ( P = 0.12). However, at the sampling time ( P = 0.0), and 5 minutes ( P = 0.001) and 30 minutes after the sampling ( P = 0.001), mean pain score in the intervention stage was significantly less than that in the control stage. Based on the findings, environmental and behavioral interventions reduced pain and facilitated heel-prick blood sampling in preterm infants.

  14. Diode step stress program for JANTX1N5615

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The effect of power/temperature step stress when applied to the switching diode JANTX1N5615 manufactured by Semtech and Micro semiconductor was examined. A total of 48 samples from each manufacturer were submitted to the process. In addition, two control sample units were maintained for verification of the electrical parametric testing. All test samples were subjected to the electrical tests after completing the prior power/temperature step stress point. Results are presented.

  15. Injection molding of iPP samples in controlled conditions and resulting morphology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sessa, Nino, E-mail: ninosessa.ns@gmail.com; De Santis, Felice, E-mail: fedesantis@unisa.it; Pantani, Roberto, E-mail: rpantani@unisa.it

    2015-12-17

    Injection molded parts are driven down in size and weight especially for electronic applications. In this work, an investigation was carried out on the process of injection molding of thin iPP samples and on the morphology of these parts. Melt flow in the mold cavity was analyzed and described with a mathematical model. Influence of mold temperature and injection pressure was analyzed. Samples orientation was studied using optical microscopy.

  16. Controlling interface oxygen for forming Ag ohmic contact to semi-polar (1 1 -2 2) plane p-type GaN

    NASA Astrophysics Data System (ADS)

    Park, Jae-Seong; Han, Jaecheon; Seong, Tae-Yeon

    2014-11-01

    Low-resistance Ag ohmic contacts to semi-polar (1 1 -2 2) p-GaN were developed by controlling interfacial oxide using a Zn layer. The 300 °C-annealed Zn/Ag samples showed ohmic behavior with a contact resistivity of 6.0 × 10-4 Ω cm2 better than that of Ag-only contacts (1.0 × 10-3 Ω cm2). The X-ray photoemission spectroscopy (XPS) results showed that annealing caused the indiffusion of oxygen at the contact/GaN interface, resulting in the formation of different types of interfacial oxides, viz. Ga-oxide and Ga-doped ZnO. Based on the XPS and electrical results, the possible mechanisms underlying the improved electrical properties of the Zn/Ag samples are discussed.

  17. INTERNAL AMPLIFICATION CONTROL FOR USE IN QUANTITATIVE POLYMERASE CHAIN REACTION FECAL INDICATOR BACTERIA ASSAYS

    EPA Science Inventory

    Quantitative polymerase chain reaction (QPCR) can be used as a rapid method for detecting fecal indicator bacteria. Because false negative results can be caused by PCR inhibitors that co-extract with the DNA samples, an internal amplification control (IAC) should be run with eac...

  18. Peer Victimization and Parental Psychological Control in Adolescence

    ERIC Educational Resources Information Center

    Ma, Ting-Lan; Bellmore, Amy

    2012-01-01

    With a sample of 831 U.S. adolescents (49% girls) followed from 9th to 11th grade, the directionality of the association between school-based peer victimization and adolescents' perception of their parents' psychological control were examined. Possible mediating influences of internalizing symptoms were also explored. The results highlight the…

  19. Getting DNA copy numbers without control samples

    PubMed Central

    2012-01-01

    Background The selection of the reference to scale the data in a copy number analysis has paramount importance to achieve accurate estimates. Usually this reference is generated using control samples included in the study. However, these control samples are not always available and in these cases, an artificial reference must be created. A proper generation of this signal is crucial in terms of both noise and bias. We propose NSA (Normality Search Algorithm), a scaling method that works with and without control samples. It is based on the assumption that genomic regions enriched in SNPs with identical copy numbers in both alleles are likely to be normal. These normal regions are predicted for each sample individually and used to calculate the final reference signal. NSA can be applied to any CN data regardless the microarray technology and preprocessing method. It also finds an optimal weighting of the samples minimizing possible batch effects. Results Five human datasets (a subset of HapMap samples, Glioblastoma Multiforme (GBM), Ovarian, Prostate and Lung Cancer experiments) have been analyzed. It is shown that using only tumoral samples, NSA is able to remove the bias in the copy number estimation, to reduce the noise and therefore, to increase the ability to detect copy number aberrations (CNAs). These improvements allow NSA to also detect recurrent aberrations more accurately than other state of the art methods. Conclusions NSA provides a robust and accurate reference for scaling probe signals data to CN values without the need of control samples. It minimizes the problems of bias, noise and batch effects in the estimation of CNs. Therefore, NSA scaling approach helps to better detect recurrent CNAs than current methods. The automatic selection of references makes it useful to perform bulk analysis of many GEO or ArrayExpress experiments without the need of developing a parser to find the normal samples or possible batches within the data. The method is available in the open-source R package NSA, which is an add-on to the aroma.cn framework. http://www.aroma-project.org/addons. PMID:22898240

  20. Comparability of river suspended-sediment sampling and laboratory analysis methods

    USGS Publications Warehouse

    Groten, Joel T.; Johnson, Gregory D.

    2018-03-06

    Accurate measurements of suspended sediment, a leading water-quality impairment in many Minnesota rivers, are important for managing and protecting water resources; however, water-quality standards for suspended sediment in Minnesota are based on grab field sampling and total suspended solids (TSS) laboratory analysis methods that have underrepresented concentrations of suspended sediment in rivers compared to U.S. Geological Survey equal-width-increment or equal-discharge-increment (EWDI) field sampling and suspended sediment concentration (SSC) laboratory analysis methods. Because of this underrepresentation, the U.S. Geological Survey, in collaboration with the Minnesota Pollution Control Agency, collected concurrent grab and EWDI samples at eight sites to compare results obtained using different combinations of field sampling and laboratory analysis methods.Study results determined that grab field sampling and TSS laboratory analysis results were biased substantially low compared to EWDI sampling and SSC laboratory analysis results, respectively. Differences in both field sampling and laboratory analysis methods caused grab and TSS methods to be biased substantially low. The difference in laboratory analysis methods was slightly greater than field sampling methods.Sand-sized particles had a strong effect on the comparability of the field sampling and laboratory analysis methods. These results indicated that grab field sampling and TSS laboratory analysis methods fail to capture most of the sand being transported by the stream. The results indicate there is less of a difference among samples collected with grab field sampling and analyzed for TSS and concentration of fines in SSC. Even though differences are present, the presence of strong correlations between SSC and TSS concentrations provides the opportunity to develop site specific relations to address transport processes not captured by grab field sampling and TSS laboratory analysis methods.

  1. IMPLICIT DUAL CONTROL BASED ON PARTICLE FILTERING AND FORWARD DYNAMIC PROGRAMMING.

    PubMed

    Bayard, David S; Schumitzky, Alan

    2010-03-01

    This paper develops a sampling-based approach to implicit dual control. Implicit dual control methods synthesize stochastic control policies by systematically approximating the stochastic dynamic programming equations of Bellman, in contrast to explicit dual control methods that artificially induce probing into the control law by modifying the cost function to include a term that rewards learning. The proposed implicit dual control approach is novel in that it combines a particle filter with a policy-iteration method for forward dynamic programming. The integration of the two methods provides a complete sampling-based approach to the problem. Implementation of the approach is simplified by making use of a specific architecture denoted as an H-block. Practical suggestions are given for reducing computational loads within the H-block for real-time applications. As an example, the method is applied to the control of a stochastic pendulum model having unknown mass, length, initial position and velocity, and unknown sign of its dc gain. Simulation results indicate that active controllers based on the described method can systematically improve closed-loop performance with respect to other more common stochastic control approaches.

  2. Differences between blood donors and a population sample: implications for case-control studies.

    PubMed

    Golding, Jean; Northstone, Kate; Miller, Laura L; Davey Smith, George; Pembrey, Marcus

    2013-08-01

    Selecting appropriate controls for studies of genetic variation in case series is important. The two major candidates involve the use of blood donors or a random sample of the population. We compare and contrast the two different populations of controls for studies of genetic variation using data from parents enrolled in the Avon Longitudinal Study of Parents and Children (ALSPAC). In addition we compute different biases using a series of hypothetical assumptions. The study subjects who had been blood donors differed markedly from the general population in social, health-related, anthropometric, and personality-related variables. Using theoretical examples, we show that blood donors are a poor control group for non-genetic studies of diseases related to environmentally, behaviourally, or socially patterned exposures. However, we show that if blood donors are used as controls in genetic studies, these factors are unlikely to make a major difference in detecting true associations with relatively rare disorders (cumulative incidence through life of <10%). Nevertheless, for more common disorders, the reduction in accuracy resulting from the inclusion in any control population of individuals who have or will develop the disease in question can create a greater bias than can socially patterned factors. Information about the medical history of a control and the parents of the control (as a proxy for whether the control will develop the disease) is more important with regard to the choice of controls than whether the controls are a random population sample or blood donors.

  3. Sucrose and color profiles in sugarcane (Saccharum sp.) juice analyzed by UFLC-ELSD and Synapt High-Definition Mass Spectrometry during radiation treatment

    NASA Astrophysics Data System (ADS)

    Lima, Roberta B.; de Aguiar, Claudio Lima; Galaverna, Renan; Baptista, Antonio S.; Eberlin, Marcos N.; Arthur, Valter

    2016-04-01

    This work evaluated the effect of electron beam irradiation (E-beam) on sugarcane juice and compared the results with preliminary tests performed on sugarcane juice treated with gamma irradiation. The samples were irradiated at 5, 10 and 20 kGy doses and results were compared wile control samples without irradiation. The results showed a significant increase (p≤0.05) of phenolic compounds in both treatments. We also observed increased contents of reducing sugars (glucose and fructose) for the samples irradiated with gamma rays and E-beam measured by the DNS methods. However, there was no significant difference of sugars content measured by chromatographic analyses performed in the sugarcane juice treated with E-beam. Therefore reducing sugars content could be overestimated by the DNS method because salts in sugarcane juice. The treatments were able to reduce sugarcane juice ICUMSA color intensity in both treatments with irradiation. E-beam reduced sugarcane juice color by roughly 49% compared the control, while gamma irradiation reduced it by 30%.

  4. Results and Conclusions from the NASA Isokinetic Total Water Content Probe 2009 IRT Test

    NASA Technical Reports Server (NTRS)

    Reehorst, Andrew; Brinker, David

    2010-01-01

    The NASA Glenn Research Center has developed and tested a Total Water Content Isokinetic Sampling Probe. Since, by its nature, it is not sensitive to cloud water particle phase nor size, it is particularly attractive to support super-cooled large droplet and high ice water content aircraft icing studies. The instrument comprises the Sampling Probe, Sample Flow Control, and Water Vapor Measurement subsystems. Results and conclusions are presented from probe tests in the NASA Glenn Icing Research Tunnel (IRT) during January and February 2009. The use of reference probe heat and the control of air pressure in the water vapor measurement subsystem are discussed. Several run-time error sources were found to produce identifiable signatures that are presented and discussed. Some of the differences between measured Isokinetic Total Water Content Probe and IRT calibration seems to be caused by tunnel humidification and moisture/ice crystal blow around. Droplet size, airspeed, and liquid water content effects also appear to be present in the IRT calibration. Based upon test results, the authors provide recommendations for future Isokinetic Total Water Content Probe development.

  5. Conservation science in a terrorist age: the impact of airport security screening on the viability and DNA integrity of frozen felid spermatozoa.

    PubMed

    Gloor, Kayleen T; Winget, Doug; Swanson, William F

    2006-09-01

    In response to growing terrorism concerns, the Transportation Security Administration now requires that all checked baggage at U.S. airports be scanned through a cabinet x-ray system, which may increase risk of radiation damage to transported biologic samples and other sensitive genetic material. The objective of this study was to investigate the effect of these new airport security regulations on the viability and DNA integrity of frozen felid spermatozoa. Semen was collected from two domestic cats (Felis silvestris catus) and one fishing cat (Prionailurus viverrinus), cryopreserved in plastic freezing straws, and transferred into liquid nitrogen dry shippers for security screening. Treatment groups included frozen samples from each male scanned once or three times using a Transportation Security Administration-operated cabinet x-ray system, in addition to non-scanned samples (i.e., negative control) and samples previously scanned three times and exposed to five additional high-intensity x-ray bursts (i.e., positive control). Dosimeters placed in empty dry shippers were used to quantify radiation exposure. Following treatment, straws were thawed and spermatozoa analyzed for post-thaw motility (percentage motile and rate of progressive movement), acrosome status, and DNA integrity using single-cell gel electrophoresis (i.e., the comet assay). Dosimeter measurements determined that each airport screening procedure produced approximately 16 mrem of radiation exposure. Our results indicated that all levels of radiation exposure adversely affected (P < 0.05) post-thaw sperm motility, but the percentage of acrosome-intact spermatozoa did not differ (P > 0.05) among treatment groups. Results also showed that the amount of double-stranded DNA damage was greater (P < 0.05) in sperm samples from both cat species scanned three times compared to samples scanned once or negative controls. Findings suggest that new airport security measures may cause radiation-induced damage to frozen spermatozoa and other valuable biologic samples transported on passenger aircraft and that alternative modes of sample transportation should be used whenever possible.

  6. Spacelab Charcoal Analyses

    NASA Technical Reports Server (NTRS)

    Slivon, L. E.; Hernon-Kenny, L. A.; Katona, V. R.; Dejarme, L. E.

    1995-01-01

    This report describes analytical methods and results obtained from chemical analysis of 31 charcoal samples in five sets. Each set was obtained from a single scrubber used to filter ambient air on board a Spacelab mission. Analysis of the charcoal samples was conducted by thermal desorption followed by gas chromatography/mass spectrometry (GC/MS). All samples were analyzed using identical methods. The method used for these analyses was able to detect compounds independent of their polarity or volatility. In addition to the charcoal samples, analyses of three Environmental Control and Life Support System (ECLSS) water samples were conducted specifically for trimethylamine.

  7. A Novel Technique for Sterilization Using a Power Self-Regulated Single-Mode Microwave Cavity.

    PubMed

    Reverte-Ors, Juan D; Pedreño-Molina, Juan L; Fernández, Pablo S; Lozano-Guerrero, Antonio J; Periago, Paula M; Díaz-Morcillo, Alejandro

    2017-06-07

    In this paper, a novel technique to achieve precise temperatures in food sterilization has been proposed. An accurate temperature profile is needed in order to reach a commitment between the total removal of pathogens inside the product and the preservation of nutritional and organoleptic characteristics. The minimal variation of the target temperature in the sample by means of a monitoring and control software platform, allowing temperature stabilization over 100 °C, is the main goal of this work. A cylindrical microwave oven, under pressure conditions and continuous control of the microwave supply power as function of the final temperature inside the sample, has been designed and developed with conditions of single-mode resonance. The uniform heating in the product is achieved by means of sample movement and the self-regulated power control using the measured temperature. Finally, for testing the sterilization of food with this technology, specific biological validation based on Bacillus cereus as a biosensor of heat inactivation has been incorporated as a distribution along the sample in the experimental process to measure the colony-forming units (CFUs) for different food samples (laboratory medium, soup, or fish-based animal by-products). The obtained results allow the validation of this new technology for food sterilization with precise control of the microwave system to ensure the uniform elimination of pathogens using high temperatures.

  8. A Novel Technique for Sterilization Using a Power Self-Regulated Single-Mode Microwave Cavity

    PubMed Central

    Reverte-Ors, Juan D.; Pedreño-Molina, Juan L.; Fernández, Pablo S.; Lozano-Guerrero, Antonio J.; Periago, Paula M.; Díaz-Morcillo, Alejandro

    2017-01-01

    In this paper, a novel technique to achieve precise temperatures in food sterilization has been proposed. An accurate temperature profile is needed in order to reach a commitment between the total removal of pathogens inside the product and the preservation of nutritional and organoleptic characteristics. The minimal variation of the target temperature in the sample by means of a monitoring and control software platform, allowing temperature stabilization over 100 °C, is the main goal of this work. A cylindrical microwave oven, under pressure conditions and continuous control of the microwave supply power as function of the final temperature inside the sample, has been designed and developed with conditions of single-mode resonance. The uniform heating in the product is achieved by means of sample movement and the self-regulated power control using the measured temperature. Finally, for testing the sterilization of food with this technology, specific biological validation based on Bacillus cereus as a biosensor of heat inactivation has been incorporated as a distribution along the sample in the experimental process to measure the colony-forming units (CFUs) for different food samples (laboratory medium, soup, or fish-based animal by-products). The obtained results allow the validation of this new technology for food sterilization with precise control of the microwave system to ensure the uniform elimination of pathogens using high temperatures. PMID:28590423

  9. Gel-based immunotest for simultaneous detection of 2,4,6-trichlorophenol and ochratoxin A in red wine.

    PubMed

    Beloglazova, N V; Goryacheva, I Yu; Rusanova, T Yu; Yurasov, N A; Galve, R; Marco, M-P; De Saeger, S

    2010-07-05

    A new rapid method which allows simultaneous one step detection of two analytes of different nature (2,4,6,-trichlorophenol (TCP) and ochratoxin A (OTA)) in red wine was developed. It was based on a column test with three separate immunolayers: two test layers and one control layer. Each layer consisted of sepharose gel with immobilized anti-OTA (OTA test layer), anti-TCP (TCP test layer) or anti-HRP (control layer) antibodies. Analytes bind to the antibodies in the corresponding test layer while sample flows through the column. Then a mixture of OTA-HRP and TCP-HRP in appropriate dilutions was used, followed by the application of chromogenic substrate. Colour development of the test layer occurred when the corresponding analyte was absent in the sample. HRP-conjugates bound to anti-HRP antibody in the control layer independently of presence or absence of analytes and a blue colour developed in the control layer. Cut-off values for both analytes were 2 microg L(-1). The described method was applied to the simultaneous detection of TCP and OTA in wine samples. To screen the analytes in red wine samples, clean-up columns were used for sample pre-treatment in combination with the test column. Results were confirmed by chromatographic methods. Copyright 2010 Elsevier B.V. All rights reserved.

  10. Mixed Model Association with Family-Biased Case-Control Ascertainment.

    PubMed

    Hayeck, Tristan J; Loh, Po-Ru; Pollack, Samuela; Gusev, Alexander; Patterson, Nick; Zaitlen, Noah A; Price, Alkes L

    2017-01-05

    Mixed models have become the tool of choice for genetic association studies; however, standard mixed model methods may be poorly calibrated or underpowered under family sampling bias and/or case-control ascertainment. Previously, we introduced a liability threshold-based mixed model association statistic (LTMLM) to address case-control ascertainment in unrelated samples. Here, we consider family-biased case-control ascertainment, where case and control subjects are ascertained non-randomly with respect to family relatedness. Previous work has shown that this type of ascertainment can severely bias heritability estimates; we show here that it also impacts mixed model association statistics. We introduce a family-based association statistic (LT-Fam) that is robust to this problem. Similar to LTMLM, LT-Fam is computed from posterior mean liabilities (PML) under a liability threshold model; however, LT-Fam uses published narrow-sense heritability estimates to avoid the problem of biased heritability estimation, enabling correct calibration. In simulations with family-biased case-control ascertainment, LT-Fam was correctly calibrated (average χ 2 = 1.00-1.02 for null SNPs), whereas the Armitage trend test (ATT), standard mixed model association (MLM), and case-control retrospective association test (CARAT) were mis-calibrated (e.g., average χ 2 = 0.50-1.22 for MLM, 0.89-2.65 for CARAT). LT-Fam also attained higher power than other methods in some settings. In 1,259 type 2 diabetes-affected case subjects and 5,765 control subjects from the CARe cohort, downsampled to induce family-biased ascertainment, LT-Fam was correctly calibrated whereas ATT, MLM, and CARAT were again mis-calibrated. Our results highlight the importance of modeling family sampling bias in case-control datasets with related samples. Copyright © 2017 American Society of Human Genetics. Published by Elsevier Inc. All rights reserved.

  11. Numerical Evaluation of the "Dual-Kernel Counter-flow" Matric Convolution Integral that Arises in Discrete/Continuous (D/C) Control Theory

    NASA Technical Reports Server (NTRS)

    Nixon, Douglas D.

    2009-01-01

    Discrete/Continuous (D/C) control theory is a new generalized theory of discrete-time control that expands the concept of conventional (exact) discrete-time control to create a framework for design and implementation of discretetime control systems that include a continuous-time command function generator so that actuator commands need not be constant between control decisions, but can be more generally defined and implemented as functions that vary with time across sample period. Because the plant/control system construct contains two linear subsystems arranged in tandem, a novel dual-kernel counter-flow convolution integral appears in the formulation. As part of the D/C system design and implementation process, numerical evaluation of that integral over the sample period is required. Three fundamentally different evaluation methods and associated algorithms are derived for the constant-coefficient case. Numerical results are matched against three available examples that have closed-form solutions.

  12. Properties of microcement mortar with nano particles

    NASA Astrophysics Data System (ADS)

    Alimeneti, Narasimha Reddy

    Carbon nanotubes (CNT) and Carbon nanofibers (CNF) are one of the toughest and stiffest materials in the world presently with extreme properties yet to be discovered in terms of elastic modulus and tensile strength. Due to the advanced properties of these materials they are being used in almost all fields of science at nanolevel and are being used in construction industry recently for improvement of material properties. Microcement is fine ground cement which as half the particle size of ordinary Portland cement. In this research the behavior of cement mortar of micro cement with the addition of nanoparticles is studied. Due to high aspect ratio and strong van der Waal forces between the particles of CNT and CNF, they agglomerate and form bundles when mixed with water, sonication method is used to mix nanoparticles with few drops of surfactant and super plasticizer. Mechanical properties such as compressive strength and flexural strength with CNT and CNF composites are examined and compared with control samples. 0.1% and 0.05 % of nanoparticles (both CNT and CNF) by the weight of cement are used in this research and 0.8% of super plasticizer by weight of cement was also used along with 0.4, 0.45 and 0.50 water cement ratios for making specimens for compression test. The compressive strength results are not satisfactory as there was no constant increase in strength with all the composites, however strength of few nanocomposites increased by a good percentage. 0.5 water cement ratio cement mortar had compressive strength of 7.15 ksi (49.3 MPa), whereas sample with 0.1% CNT showed 8.38 ksi (57.8 MPa) with 17% increase in strength after 28 days. Same trend was followed by 0.4 water cement ratio as the compressive strength of control sample was 8.89 ksi (61.3 MPa), with 0.05% of CNT strength increased to 10.90 ksi (75.2 MPa) with 23% increase in strength. 0.4 water cement ratio was used for flexural tests including 0.1%, 0.05% of CNT and 0.1%, 0.05% of CNF with 0.008 ratio of super plasticizer. Results showed that there was a significant increase in strength initially but gradually decreased as the time increase and showed decreased strength at 28 days when compared to control samples. Flow cone results are quite satisfying as the flow is significantly increased with the addition of nanoparticles. Time of efflux of control sample is 16.22 sec whereas for specimen with CNT had a time of efflux 12.67 sec and sample with CNF showed 13.65 seconds. Setting time test was carried on 0.4 water cement ratio. Composites with nanoparticles exhibited faster setting when compared to its control sample. Bleeding was not observed with the nanoparticles in the cement mortar. Shrinkage test was conducted on sample with 0.4 water cement ratio with 0.05% of CNT and CNF. Shrinkage was very small in the samples with nanoparticles.

  13. Simultaneous detection, typing and quantitation of oncogenic human papillomavirus by multiplex consensus real-time PCR.

    PubMed

    Jenkins, Andrew; Allum, Anne-Gry; Strand, Linda; Aakre, Randi Kersten

    2013-02-01

    A consensus multiplex real-time PCR test (PT13-RT) for the oncogenic human papillomavirus (HPV) types 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59 and 66 is described. The test targets the L1 gene. Analytical sensitivity is between 4 and 400 GU (genomic units) in the presence of 500 ng of human DNA, corresponding to 75,000 human cells. HPV types are grouped into multiplex groups of 3 or 4 resulting in the use of 4 wells per sample and permitting up to 24 samples per run (including controls) in a standard 96-well real-time PCR instrument. False negative results are avoided by (a) measuring sample DNA concentration to control that sufficient cellular material is present and (b) including HPV type 6 as a homologous internal control in order to detect PCR inhibition or competition from other (non-oncogenic) HPV types. Analysis time from refrigerator to report is 8 h, including 2.5 h hands-on time. Relative to the HC2 test, the sensitivity and specificity were respectively 98% and 83%, the lower specificity being attributable to the higher analytical sensitivity of PT13-RT. To assess type determination comparison was made with a reversed line-blot test. Type concordance was high (κ=0.79) with discrepancies occurring mostly in multiple-positive samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Improvement in the traditional processing method and nutritional quality of traditional extruded cassava-based snack (modified Ajogun).

    PubMed

    Obadina, Adewale O; Oyewole, Olusola B; Williams, Oluwasolabomi E

    2013-07-01

    This study was carried out to investigate and improve the traditional processing method and nutritional quality of the traditional cassava snack (Ajogun). Cassava root (Manihot esculenta Crantz L.) of TME 419 variety was processed into mash (40% moisture content). The cassava mash was mixed into different blends to produce fried traditional "Ajogun", fried and baked extrudates (modified Ajogun) as snacks. These products were analyzed to determine the proximate composition including carbohydrate, fat, protein, fiber, ash, and moisture contents and functional properties such as bulk density. The results obtained for the moisture, fat, protein, and ash contents showed significant difference (P < 0.05) between the control sample and the extrudates. However, there was no significant difference (P > 0.05) in the carbohydrate and fiber contents between the three samples. There was no significant difference (P > 0.05) in the bulk density of the snacks. Also, sensory evaluation was carried out on the cassava-based snacks using the 9-point hedonic scale to determine the degree of acceptability. Results obtained showed significant difference (P < 0.05) between the extrudates and control sample in terms of appearance, taste, flavor, color, aroma, texture, and overall acceptability. The highest acceptability level of the product was at 8.04 for the control sample (traditional Ajogun). This study has shown that "Ajogun", which is a lesser known cassava product, is rich in protein and fat.

  15. Fully automated, internally controlled quantification of hepatitis B Virus DNA by real-time PCR by use of the MagNA Pure LC and LightCycler instruments.

    PubMed

    Leb, Victoria; Stöcher, Markus; Valentine-Thon, Elizabeth; Hölzl, Gabriele; Kessler, Harald; Stekel, Herbert; Berg, Jörg

    2004-02-01

    We report on the development of a fully automated real-time PCR assay for the quantitative detection of hepatitis B virus (HBV) DNA in plasma with EDTA (EDTA plasma). The MagNA Pure LC instrument was used for automated DNA purification and automated preparation of PCR mixtures. Real-time PCR was performed on the LightCycler instrument. An internal amplification control was devised as a PCR competitor and was introduced into the assay at the stage of DNA purification to permit monitoring for sample adequacy. The detection limit of the assay was found to be 200 HBV DNA copies/ml, with a linear dynamic range of 8 orders of magnitude. When samples from the European Union Quality Control Concerted Action HBV Proficiency Panel 1999 were examined, the results were found to be in acceptable agreement with the HBV DNA concentrations of the panel members. In a clinical laboratory evaluation of 123 EDTA plasma samples, a significant correlation was found with the results obtained by the Roche HBV Monitor test on the Cobas Amplicor analyzer within the dynamic range of that system. In conclusion, the newly developed assay has a markedly reduced hands-on time, permits monitoring for sample adequacy, and is suitable for the quantitative detection of HBV DNA in plasma in a routine clinical laboratory.

  16. One fish, two fish, we QC fish: controlling data quality among more than 50 organizations over a four-year period.

    PubMed

    Riddick, L; Simbanin, C

    2001-01-01

    EPA is conducting a National Study of Chemical Residues in Lake Fish Tissue. The study involves five analytical laboratories, multiple sampling teams from each of the 47 participating states, several tribes, all 10 EPA Regions and several EPA program offices, with input from other federal agencies. To fulfill study objectives, state and tribal sampling teams are voluntarily collecting predator and bottom-dwelling fish from approximately 500 randomly selected lakes over a 4-year period. The fish will be analyzed for more than 300 pollutants. The long-term nature of the study, combined with the large number of participants, created several QA challenges: (1) controlling variability among sampling activities performed by different sampling teams from more than 50 organizations over a 4-year period; (2) controlling variability in lab processes over a 4-year period; (3) generating results that will meet the primary study objectives for use by OW statisticians; (4) generating results that will meet the undefined needs of more than 50 participating organizations; and (5) devising a system for evaluating and defining data quality and for reporting data quality assessments concurrently with the data to ensure that assessment efforts are streamlined and that assessments are consistent among organizations. This paper describes the QA program employed for the study and presents an interim assessment of the program's effectiveness.

  17. Localised drug release using MRI-controlled focused ultrasound hyperthermia.

    PubMed

    Staruch, Robert; Chopra, Rajiv; Hynynen, Kullervo

    2011-01-01

    Thermosensitive liposomes provide a mechanism for triggering the local release of anticancer drugs, but this technology requires precise temperature control in targeted regions with minimal heating of surrounding tissue. The objective of this study was to evaluate the feasibility of using MRI-controlled focused ultrasound (FUS) and thermosensitive liposomes to achieve thermally mediated localised drug delivery in vivo. Results are reported from ten rabbits, where a FUS beam was scanned in a circular trajectory to heat 10-15 mm diameter regions in normal thigh to 43°C for 20-30 min. MRI thermometry was used for closed-loop feedback control to achieve temporally and spatially uniform heating. Lyso-thermosensitive liposomal doxorubicin was infused intravenously during hyperthermia. Unabsorbed liposomes were flushed from the vasculature by saline perfusion 2 h later, and tissue samples were harvested from heated and unheated thigh regions. The fluorescence intensity of the homogenised samples was used to calculate the concentration of doxorubicin in tissue. Closed-loop control of FUS heating using MRI thermometry achieved temperature distributions with mean, T90 and T10 of 42.9°C, 41.0°C and 44.8°C, respectively, over a period of 20 min. Doxorubicin concentrations were significantly higher in tissues sampled from heated than unheated regions of normal thigh muscle (8.3 versus 0.5 ng/mg, mean per-animal difference = 7.8 ng/mg, P < 0.05, Wilcoxon matched pairs signed rank test). The results show the potential of MRI-controlled focused ultrasound hyperthermia for enhanced local drug delivery with temperature-sensitive drug carriers.

  18. Randomized clinical trial to evaluate the efficacy of a 5-day ceftiofur hydrochloride intramammary treatment on nonsevere gram-negative clinical mastitis.

    PubMed

    Schukken, Y H; Bennett, G J; Zurakowski, M J; Sharkey, H L; Rauch, B J; Thomas, M J; Ceglowski, B; Saltman, R L; Belomestnykh, N; Zadoks, R N

    2011-12-01

    The objective of this study was to evaluate the efficacy of intramammary treatment with ceftiofur hydrochloride of nonsevere, clinical coliform mastitis. One hundred four cases on 5 farms met the enrollment criteria for the study. Escherichia coli was the most common coliform species identified in milk samples from cows with mild to moderate clinical mastitis, followed by Klebsiella spp. and Enterobacter spp. At enrollment, a milk sample from the affected quarter was taken and used for on-farm culture or submitted to the laboratory. For cows in the treatment group, treatment was initiated with ceftiofur hydrochloride via intramammary infusion at 24-h intervals for 5 d according to label standards. Cows in the control group did not receive treatment. Culture results were available on the day after enrollment and only cows with coliform mastitis continued in the treatment and untreated control groups. Bacteriological cure was defined based on 2 posttreatment milk samples. Molecular typing was used for final definition of bacteriological cure. Treatment of nonsevere clinical gram-negative mastitis with ceftiofur hydrochloride resulted in a significant increase in bacteriological cure compared with nontreated controls in animals infected with E. coli or Klebsiella spp. Treated animals clinically improved significantly more compared with control cows. No significant differences were observed between treated and control animals in milk production or linear score before or after clinical mastitis. Treated animals left the study less frequently compared with control animals. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  19. Fracture resistance exhibited by endodontically treated and retreated teeth shaped by ProTaper NEXT versus WaveOne: An in vitro study

    PubMed Central

    Khalap, Neha Deepak; Hegde, Vibha; Kokate, Sharad

    2015-01-01

    Aim: To compare the fracture resistance exhibited by teeth after primary endodontic treatment and retreatment. Materials and Methods: One hundred freshly extracted human teeth were selected. 20 samples served as control (untreated). Eighty experimental samples were divided into two groups (n = 40) for instrumentation using rotary Protaper NEXT (PTN) or reciprocating WaveOne (WO) files and obturated using warm lateral compaction. Half of the samples (n = 20) from each group were subjected to a load. The remaining half were subjected to retreatment using Protaper universal retreatment files (RFs) followed by a file larger than the master apical file used in groups 1 and 2 and reobturated. Group A: Control, Group B: PTN + obturation, Group C: WO + obturation, Group D: RF + PTN + obturation and Group E: RF + WO + obturation. The retreatment specimens were also subjected to load and the readings acquired were statistically analyzed. Result: When compared between the groups, control group exhibited the highest fracture resistance (P < 0.01). When multiple tests were performed, Group E exhibited significantly less fracture resistance (P < 0.01). Conclusion: Endodontic treatment and retreatment both results in lowering the fracture resistance of a tooth. PMID:26752838

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    CALLAWAY WS; HUBER HJ

    Based on an ENRAF waste surface measurement taken February 1, 2009, double-shell tank (DST) 241-AN-106 (AN-106) contained approximately 278.98 inches (793 kgal) of waste. A zip cord measurement from the tank on February 1, 2009, indicated a settled solids layer of 91.7 inches in height (280 kgal). The supernatant layer in February 2009, by difference, was approximately 187 inches deep (514 kgal). Laboratory results from AN-106 February 1, 2009 (see Table 2) grab samples indicated the supernatant was below the chemistry limit that applied at the time as identified in HNF-SD-WM-TSR-006, Tank Farms Technical Safety Requirements, Administrative Control (AC) 5.16,more » 'Corrosion Mitigation Controls.' (The limits have since been removed from the Technical Safety Requirements (TSR) and are captured in OSD-T-151-00007, Operating Specifications for the Double-Shell Storage Tanks.) Problem evaluation request WRPS-PER-2009-0218 was submitted February 9, 2009, to document the finding that the supernatant chemistry for grab samples taken from the middle and upper regions of the supernatant was noncompliant with the chemistry control limits. The lab results for the samples taken from the bottom region of the supernatant met AC 5.16 limits.« less

  1. Formulation, sensory evaluation, proximate composition and storage stability of cassava strips produced from the composite flour of cassava and cowpea.

    PubMed

    Dada, Toluwase A; Barber, Lucretia I; Ngoma, Lubanza; Mwanza, Mulunda

    2018-03-01

    The study developed an acceptable formula for the production of cassava strips (a deep fried product) using composite flour of cassava/cowpea at four different levels of cowpea substitutions (100:0, 90:10, 80:20, and 70:30). Sensory properties, proximate composition, and shelf life at ambient temperature were determined. Proximate composition, shelf life, and microbial analysis were further done on the most preferred sample (80:20) and the control (100:0). Results showed a significant difference between the tested sample and the control, except in their moisture (4.1%-4.2%) and fiber (5.0%) contents which were similar. Protein content increased from 0.9% to 2.6%, fat 24.6% to 28.5%, carbohydrate 59.7% to 61.1%, and ash 1.8% to 2.5% in both control and most preferred sample. Results showed no changes in their peroxide value (2.4 mEq/kg), moisture content (4.1%), and bacterial count of 0 × 10 2  CFU/g at ambient storage temperature for 4 weeks. The addition of cowpea flour increased the nutritional quality of the cassava strips.

  2. Properties of Frankfurter-type Sausages with Pork Back-fat Replaced with Bovine Heart Surimi-like Materials

    PubMed Central

    Seo, Jin-Kyu; Yum, Hyeon-Woong; Kim, Gap-Don; Jeong, Jin-Yeon; Yang, Han-Sul

    2016-01-01

    This study investigates the effect of bovine heart surimi-like material (BHSM) used as a back fat replacer, on the physicochemical and sensory characteristics of frankfurter-type sausages. Frankfurter-type sausage with added BHSM had a higher moisture content and lower fat content than the control. In addition, the samples with added BHSM had higher pH, cooking loss and 2-thiobarbituric acid-reactive substance (TBARS) value and lower water exudation than the control. The sausage formulation with 40% BHSM was more effective in delaying lipid oxidation without affecting cooking loss compared to the 60% BHSM treatment sample. Results showed that hardness values increased upon replacement with BHSM, and sausages manufactured with 40% BHSM had higher lightness and lower redness values. Panelists found there were no differences in color, odor, and tenderness scores and the overall acceptability score found that treatment samples containing 20% and 40% BHSM were preferable to the control after storage for 14 d. These results indicate that fat replacement with BHSM was beneficial to the quality of frankfurter-type sausages, and acceptable reduced-fat products can be produced when back fat is replaced with up to 40% BHSM. PMID:27621694

  3. Properties of Frankfurter-type Sausages with Pork Back-fat Replaced with Bovine Heart Surimi-like Materials.

    PubMed

    Seo, Jin-Kyu; Yum, Hyeon-Woong; Kim, Gap-Don; Jeong, Jin-Yeon; Yang, Han-Sul

    2016-01-01

    This study investigates the effect of bovine heart surimi-like material (BHSM) used as a back fat replacer, on the physicochemical and sensory characteristics of frankfurter-type sausages. Frankfurter-type sausage with added BHSM had a higher moisture content and lower fat content than the control. In addition, the samples with added BHSM had higher pH, cooking loss and 2-thiobarbituric acid-reactive substance (TBARS) value and lower water exudation than the control. The sausage formulation with 40% BHSM was more effective in delaying lipid oxidation without affecting cooking loss compared to the 60% BHSM treatment sample. Results showed that hardness values increased upon replacement with BHSM, and sausages manufactured with 40% BHSM had higher lightness and lower redness values. Panelists found there were no differences in color, odor, and tenderness scores and the overall acceptability score found that treatment samples containing 20% and 40% BHSM were preferable to the control after storage for 14 d. These results indicate that fat replacement with BHSM was beneficial to the quality of frankfurter-type sausages, and acceptable reduced-fat products can be produced when back fat is replaced with up to 40% BHSM.

  4. Evaluation of the COBAS Hepatitis C Virus (HCV) TaqMan analyte-specific reagent assay and comparison to the COBAS Amplicor HCV Monitor V2.0 and Versant HCV bDNA 3.0 assays.

    PubMed

    Konnick, Eric Q; Williams, Sheri M; Ashwood, Edward R; Hillyard, David R

    2005-05-01

    Performance characteristics of the COBAS hepatitis C virus (HCV) TaqMan analyte-specific reagent (TM-ASR) assay using the QIAGEN BioRobot 9604 for RNA extraction were evaluated and compared to the COBAS Amplicor HCV Monitor V2.0 (Amplicor) and Versant HCV bDNA 3.0 (Versant) assays using clinical samples. Calibration of TM-ASR using Armored RNA allowed determination of the distribution of HCV RNA in clinical samples, using 22,399 clinical samples. Limit of detection, linearity, and inter- and intraassay assay precision were determined for the TM-ASR assay using multiple clinical specimen panels across multiple determinations. Genotype specificity for the TM-ASR assay was determined using samples with different HCV RNA genotypes evaluated and compared against predetermined results. Contamination control of the TM-ASR assay was evaluated using pools of HCV RNA-positive and -negative samples tested in a checkerboard pattern over 12 runs of 96 samples. Correlation of the TM-ASR, Amplicor, and Versant assays was determined using 100 paired clinical samples and Deming regression analysis. The TM-ASR performed well with respect to linearity, precision, and contamination control. The correlation between TM-ASR and the Amplicor and Versant assays was poor, with large differences between assay results for individual samples. Calibration of the TM-ASR assay with Armored RNA allowed for a wide dynamic range and description of the distribution of HCV RNA in clinical samples.

  5. Evaluation of the COBAS Hepatitis C Virus (HCV) TaqMan Analyte-Specific Reagent Assay and Comparison to the COBAS Amplicor HCV Monitor V2.0 and Versant HCV bDNA 3.0 Assays

    PubMed Central

    Konnick, Eric Q.; Williams, Sheri M.; Ashwood, Edward R.; Hillyard, David R.

    2005-01-01

    Performance characteristics of the COBAS hepatitis C virus (HCV) TaqMan analyte-specific reagent (TM-ASR) assay using the QIAGEN BioRobot 9604 for RNA extraction were evaluated and compared to the COBAS Amplicor HCV Monitor V2.0 (Amplicor) and Versant HCV bDNA 3.0 (Versant) assays using clinical samples. Calibration of TM-ASR using Armored RNA allowed determination of the distribution of HCV RNA in clinical samples, using 22,399 clinical samples. Limit of detection, linearity, and inter- and intraassay assay precision were determined for the TM-ASR assay using multiple clinical specimen panels across multiple determinations. Genotype specificity for the TM-ASR assay was determined using samples with different HCV RNA genotypes evaluated and compared against predetermined results. Contamination control of the TM-ASR assay was evaluated using pools of HCV RNA-positive and -negative samples tested in a checkerboard pattern over 12 runs of 96 samples. Correlation of the TM-ASR, Amplicor, and Versant assays was determined using 100 paired clinical samples and Deming regression analysis. The TM-ASR performed well with respect to linearity, precision, and contamination control. The correlation between TM-ASR and the Amplicor and Versant assays was poor, with large differences between assay results for individual samples. Calibration of the TM-ASR assay with Armored RNA allowed for a wide dynamic range and description of the distribution of HCV RNA in clinical samples. PMID:15872232

  6. Investigating the Prevalence of Human Papilloma Virus in Squamous Cell Carcinoma of the Larynx and Its Correlation with Disease Prognosis.

    PubMed

    Atighechi, Saeid; Meybodian, Mojtaba; Dadgarnia, Mohammad Hossein; Baradaranfar, Mohammad Hossein; Behniafard, Nasim

    2016-05-01

    The human papilloma virus (HPV) can play a role in the development of head and neck squamous cell carcinoma (SCC). Our aim was to assess the prevalence of HPV DNA in SCC of the larynx. The impact of HPV infection on patient survival was also evaluated. This case-control study was performed in 44 patients with SCC of the larynx (case group), while the control group comprised samples obtained from cadavers with no previous history of malignancy. A preliminary pathologic evaluation was performed on all samples in the control group (36 samples) to ensure the absence of dysplasia or malignancy. Polymerase chain reaction (PCR) was used to detect HPV DNA. After completing the treatment protocol, patients were followed to assess the impact of HPV infection on overall survival (OS). PCR evaluation in the case group showed that HPV DNA was successfully isolated from 11 (25%) samples, while only two (5.6%) HPV DNA-positive were obtained from cadavers. According to these results, a significant difference was obtained in the prevalence of HPV DNA and laryngeal SCC between cases and controls (P=0.031). No statistically significant difference was observed in the OS of patients with or without HPV infection in the case group (P=0.235). Based on these results, we suggest that the prevalence of HPV infection is higher in laryngeal SCC subjects compared with healthy individuals. Although a longer OS was seen in HPV-positive patients, survival analysis did not show a significant difference in the comparison of HPV-positive and negative findings in SCC patients.

  7. Genome-wide association study meta-analysis of European and Asian-ancestry samples identifies three novel loci associated with bipolar disorder.

    PubMed

    Chen, D T; Jiang, X; Akula, N; Shugart, Y Y; Wendland, J R; Steele, C J M; Kassem, L; Park, J-H; Chatterjee, N; Jamain, S; Cheng, A; Leboyer, M; Muglia, P; Schulze, T G; Cichon, S; Nöthen, M M; Rietschel, M; McMahon, F J; Farmer, A; McGuffin, P; Craig, I; Lewis, C; Hosang, G; Cohen-Woods, S; Vincent, J B; Kennedy, J L; Strauss, J

    2013-02-01

    Meta-analyses of bipolar disorder (BD) genome-wide association studies (GWAS) have identified several genome-wide significant signals in European-ancestry samples, but so far account for little of the inherited risk. We performed a meta-analysis of ∼750,000 high-quality genetic markers on a combined sample of ∼14,000 subjects of European and Asian-ancestry (phase I). The most significant findings were further tested in an extended sample of ∼17,700 cases and controls (phase II). The results suggest novel association findings near the genes TRANK1 (LBA1), LMAN2L and PTGFR. In phase I, the most significant single nucleotide polymorphism (SNP), rs9834970 near TRANK1, was significant at the P=2.4 × 10(-11) level, with no heterogeneity. Supportive evidence for prior association findings near ANK3 and a locus on chromosome 3p21.1 was also observed. The phase II results were similar, although the heterogeneity test became significant for several SNPs. On the basis of these results and other established risk loci, we used the method developed by Park et al. to estimate the number, and the effect size distribution, of BD risk loci that could still be found by GWAS methods. We estimate that >63,000 case-control samples would be needed to identify the ∼105 BD risk loci discoverable by GWAS, and that these will together explain <6% of the inherited risk. These results support previous GWAS findings and identify three new candidate genes for BD. Further studies are needed to replicate these findings and may potentially lead to identification of functional variants. Sample size will remain a limiting factor in the discovery of common alleles associated with BD.

  8. The brown seaweed Sargassum cymosum: changes in metabolism and cellular organization after long-term exposure to cadmium.

    PubMed

    Costa, Giulia B; Simioni, Carmen; Pereira, Débora T; Ramlov, Fernanda; Maraschin, Marcelo; Chow, Fungyi; Horta, Paulo A; Bouzon, Zenilda L; Schmidt, Éder C

    2017-03-01

    Sargassum cymosum was exposed to cadmium (Cd) to determine any physiological and ultrastructural effects. To accomplish this, S. cymosum samples were cultivated under photosynthetic active radiation (PAR) and Cd (0, 0.1, 0.2, 0.4 and 0.8 mg L -1 ) during 7 and 14 days in laboratory-controlled conditions (0 mg L -1 Cd at both exposure times as control). Seaweeds had high retention capacity (over 90 %) for both exposure times. Growth rates showed significant increases by 14 days, especially for 0.1 and 0.4 mg L -1 Cd. Photosynthetic parameters were unaffected by Cd treatments. Chlorophyll contents were present in higher concentrations for all Cd treatments compared to respective control. Carotenoid profile showed significant differences in total composition and proportion of fucoxanthin and β-carotene, and no lutein was detected at 14 days. Phenolic and flavonoid compounds showed major accumulation at 14 days. Transmission electron microscopy (TEM) analyses presented major alterations in Cd-treated samples, when compared with respective control, in particular disorganization of cell wall fibrils. When compared to respective control samples, multivariate analyses showed disparate and complex interactions among metabolites in Cd-exposed seaweeds, giving evidence of physiological defence response. Thus, it can be concluded that Cd is a stressor for S. cymosum, resulting in physiological and structural alterations related to defence mechanisms against oxidative stress and toxicological effects resulting from long-term metal exposure. However, in the present paper, some observed changes also appear to result from acclimation mechanisms under lower concentration of Cd relative to the tolerance of S. cymosum to experimental conditions.

  9. Method for producing a thin sample band in a microchannel device

    DOEpatents

    Griffiths, Stewart K [Livermore, CA; Nilson, Robert H [Cardiff, CA

    2004-08-03

    The present invention improves the performance of microchannel systems for chemical and biological synthesis and analysis by providing a method and apparatus for producing a thin band of a species sample. Thin sample bands improve the resolution of microchannel separation processes, as well as many other processes requiring precise control of sample size and volume. The new method comprises a series of steps in which a species sample is manipulated by controlled transport through a junction formed at the intersection of four or more channels. A sample is first inserted into the end of one of these channels in the vicinity of the junction. Next, this sample is thinned by transport across the junction one or more times. During these thinning steps, flow enters the junction through one of the channels and exists through those remaining, providing a divergent flow field that progressively stretches and thins the band with each traverse of the junction. The thickness of the resulting sample band may be smaller than the channel width. Moreover, the thickness of the band may be varied and controlled by altering the method alone, without modification to the channel or junction geometries. The invention is applicable to both electroosmotic and electrophoretic transport, to combined electrokinetic transport, and to some special cases in which bulk fluid transport is driven by pressure gradients. It is further applicable to channels that are open, filled with a gel or filled with a porous or granular material.

  10. Apparatus for producing a thin sample band in a microchannel system

    DOEpatents

    Griffiths, Stewart K [Livermore, CA; Nilson, Robert H [Cardiff, CA

    2008-05-13

    The present invention improves the performance of microchannel systems for chemical and biological synthesis and analysis by providing a method and apparatus for producing a thin band of a species sample. Thin sample bands improve the resolution of microchannel separation processes, as well as many other processes requiring precise control of sample size and volume. The new method comprises a series of steps in which a species sample is manipulated by controlled transport through a junction formed at the intersection of four or more channels. A sample is first inserted into the end of one of these channels in the vicinity of the junction. Next, this sample is thinned by transport across the junction one or more times. During these thinning steps, flow enters the junction through one of the channels and exists through those remaining, providing a divergent flow field that progressively stretches and thins the band with each traverse of the junction. The thickness of the resulting sample band may be smaller than the channel width. Moreover, the thickness of the band may be varied and controlled by altering the method alone, without modification to the channel or junction geometries. The invention is applicable to both electroosmotic and electrophoretic transport, to combined electrokinetic transport, and to some special cases in which bulk fluid transport is driven by pressure gradients. It is further applicable to channels that are open, filled with a gel or filled with a porous or granular material.

  11. [Applying competitive polymerase chain reaction to the detection of hepatitis B virus DNA].

    PubMed

    Wang, Ling; Yang, Peng; Li, Shuang-qing; Xu, Shu-hui; Cao, Gui-qun; Zhang, Fa-qiang; Zhang, Mei-xia; Chen, Qing-ying; Xia, Qing-jie; Liu, Kai; Tang, Fang; Zhang, Yuan-zheng

    2004-11-01

    To reduce the rate of accidental false negative result in the HBV DNA PCR test on clinical serum samples. A competitive polymerase chain reaction (C-PCR) was used to decrease the false negative ratio. In the C-PCR, a constructed inner control DNA was added for co-amplification with the HBV target DNA. In a 20 microl C-PCR system, about 60 to 200 copies of inner control DNA could give apparent co-amplification signal band after electrophoresis on a 2% agarose gel. Five of 120 samples of clinical serum (4.2%) could not be amplified. C-PCR has the advantage of yielding information on false negative in the HBV DNA PCR assay of clinical serum samples.

  12. Vancomycin-Resistant Enterococci (VRE) in The Intensive Care Unit in a Nonoutbreak Setting: Identification of Potential Reservoirs and Epidemiological Associations Between Patient and Environmental VRE.

    PubMed

    McDermott, Hélène; Skally, Mairead; O'Rourke, James; Humphreys, Hilary; Fitzgerald-Hughes, Deirdre

    2018-01-01

    OBJECTIVE Among nosocomial bloodstream infections caused by enterococcal species, Ireland has the highest proportion caused by vancomycin-resistant enterococci (VRE) in Europe at 45.8%. The contribution of the near-patient environment to VRE transmission outside of outbreaks was investigated. DESIGN A prospective observational study was conducted during 7 sampling periods. METHODS Recovery of VRE isolates by swabbing the near-patient environment and patients in the intensive care unit (ICU) was conducted to identify reservoirs, clinical and molecular epidemiological associations, and the success of active surveillance cultures (ASCs). RESULTS Of 289 sampling occasions involving 157 patients and their bed spaces, VRE isolates were recovered from patient bed spaces, clinical samples, or both on 114 of 289 sampling occasions (39.4%). The patient and their bed space were positive for VRE on 34 of 114 VRE-associated sampling occasions (29.8%). Of 1,647 environment samples, 107 sites (6.5%) were VRE positive, with significantly greater VRE recovery from isolation rooms than from the open-plan area (9.1% vs 4.1%; P < .0001). The most frequently VRE-contaminated sites were the drip stand, bed control panel, and chart holders, which together accounted for 61% of contaminated sites. The use of ASCs resulted in a 172% increase in identification of VRE-colonized patients. Molecular typing revealed 2 environmental clusters, 1 cluster involving 3 patients and generally greater heterogeneity of patient isolates compared to environmental isolates. CONCLUSION Even outside of outbreaks, near-patient ICU environmental contamination with VRE is common. Better infection control policies that limit environmental transmission of VRE in the ICU and that are supported by molecular epidemiological studies, in real time, are needed. Infect Control Hosp Epidemiol 2018;39:40-45.

  13. A molecular identification system for grasses: a novel technology for forensic botany.

    PubMed

    Ward, J; Peakall, R; Gilmore, S R; Robertson, J

    2005-09-10

    Our present inability to rapidly, accurately and cost-effectively identify trace botanical evidence remains the major impediment to the routine application of forensic botany. Grasses are amongst the most likely plant species encountered as forensic trace evidence and have the potential to provide links between crime scenes and individuals or other vital crime scene information. We are designing a molecular DNA-based identification system for grasses consisting of several PCR assays that, like a traditional morphological taxonomic key, provide criteria that progressively identify an unknown grass sample to a given taxonomic rank. In a prior study of DNA sequences across 20 phylogenetically representative grass species, we identified a series of potentially informative indels in the grass mitochondrial genome. In this study we designed and tested five PCR assays spanning these indels and assessed the feasibility of these assays to aid identification of unknown grass samples. We confirmed that for our control set of 20 samples, on which the design of the PCR assays was based, the five primer combinations produced the expected results. Using these PCR assays in a 'blind test', we were able to identify 25 unknown grass samples with some restrictions. Species belonging to genera represented in our control set were all correctly identified to genus with one exception. Similarly, genera belonging to tribes in the control set were correctly identified to the tribal level. Finally, for those samples for which neither the tribal or genus specific PCR assays were designed, we could confidently exclude these samples from belonging to certain tribes and genera. The results confirmed the utility of the PCR assays and the feasibility of developing a robust full-scale usable grass identification system for forensic purposes.

  14. Effects of cognitive control training on the dynamics of (mal)adaptive emotion regulation in daily life.

    PubMed

    Hoorelbeke, Kristof; Koster, Ernst H W; Demeyer, Ineke; Loeys, Tom; Vanderhasselt, Marie-Anne

    2016-10-01

    Cognitive control plays a key role in both adaptive emotion regulation, such as positive reappraisal, and maladaptive emotion regulation, such as rumination, with both strategies playing a major role in resilience and well-being. As a result, cognitive control training (CCT) targeting working memory functioning may have the potential to reduce maladaptive emotion regulation and increase adaptive emotion regulation. The current study explored the effects of CCT on positive reappraisal ability in a lab context, and deployment and efficacy of positive appraisal and rumination in daily life. A sample of undergraduates (n = 83) was allocated to CCT or an active control condition, performing 10 online training sessions over a period of 14 days. Effects on regulation of affective states in daily life were assessed using experience sampling over a 7-day posttraining period. Results revealed a positive association between baseline cognitive control and self-reported use of adaptive emotion regulation strategies, whereas maladaptive emotion regulation strategies showed a negative association. CCT showed transfer to working memory functioning on the dual n-back task. Overall, effects of CCT on emotion regulation were limited to reducing deployment of rumination in low positive affective states. However, we did not find beneficial effects on indicators of adaptive emotion regulation. These findings are in line with previous studies targeting maladaptive emotion regulation but suggest limited use in enhancing adaptive emotion regulation in a healthy sample. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  15. Comparative study on serum levels of macro and trace elements in schizophrenia based on supervised learning methods.

    PubMed

    Lin, Tong; Liu, Tiebing; Lin, Yucheng; Yan, Lailai; Chen, Zhongxue; Wang, Jingyu

    2017-09-01

    The etiology and pathophysiology of schizophrenia (SCZ) remain obscure. This study explored the associations between SCZ risk and serum levels of 39 macro and trace elements (MTE). A 1:1 matched case-control study was conducted among 114 schizophrenia patients and 114 healthy controls matched by age, sex and region. Blood samples were collected to determine the concentrations of 39 MTE by ICP-AES and ICP-MS. Both supervised learning methods and classical statistical testing were used to uncover the difference of MTE levels between cases and controls. The best prediction accuracies were 99.21% achieved by support vector machines in the original feature space (without dimensionality reduction), and 98.82% achieved by Naive Bayes with dimensionality reduction. More than half of MTE were found to be significantly different between SCZ patients and the controls. The presented investigation showed that there existed remarkable differences in concentrations of MTE between SCZ patients and healthy controls. The results of this study might be useful to diagnosis and prognosis of SCZ; they also indicated other promising applications in pharmacy and nutrition. However, the results should be interpreted with caution due to limited sample size and the lack of potential confounding factors, such as alcohol, smoking, body mass index (BMI), use of antipsychotics and dietary intakes. In the future the application of the analyses will be useful in designs that have larger sample sizes. Copyright © 2017 Elsevier GmbH. All rights reserved.

  16. THE EFFECTS OF FIXED VERSUS ESCALATING REINFORCEMENT SCHEDULES ON SMOKING ABSTINENCE

    PubMed Central

    Romanowich, Paul; Lamb, R. J.

    2015-01-01

    Studies indicate that when abstinence is initiated, escalating reinforcement schedules maintain continuous abstinence longer than fixed reinforcement schedules. However, these studies were conducted for shorter durations than most clinical trials and also resulted in larger reinforcer value for escalating participants during the 1st week of the experiment. We tested whether escalating reinforcement schedules maintained abstinence longer than fixed reinforcement schedules in a 12-week clinical trial. Smokers (146) were randomized to an escalating reinforcement schedule, a fixed reinforcement schedule, or a control condition. Escalating reinforcement participants received $5.00 for their first breath carbon monoxide (CO) sample <3 ppm, with a $0.50 increase for each consecutive sample. Fixed reinforcement participants received $19.75 for each breath CO sample <3 ppm. Control participants received payments only for delivering a breath CO sample. Similar proportions of escalating and fixed reinforcement participants met the breath CO criterion at least once. Escalating reinforcement participants maintained criterion breath CO levels longer than fixed reinforcement and control participants. Similar to previous short-term studies, escalating reinforcement schedules maintained longer durations of abstinence than fixed reinforcement schedules during a clinical trial. PMID:25640764

  17. Low-noise humidity controller for imaging water mediated processes in atomic force microscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaponenko, I., E-mail: iaroslav.gaponenko@unige.ch; Gamperle, L.; Herberg, K.

    2016-06-15

    We demonstrate the construction of a novel low-noise continuous flow humidity controller and its integration with a commercial variable-temperature atomic force microscope fluid cell, allowing precise control of humidity and temperature at the sample during nanoscale measurements. Based on wet and dry gas mixing, the design allows a high mechanical stability to be achieved by means of an ultrasonic atomiser for the generation of water-saturated gas, improving upon previous bubbler-based architectures. Water content in the flow is measured both at the inflow and outflow of the fluid cell, enabling the monitoring of water condensation and icing, and allowing controlled variationmore » of the sample temperature independently of the humidity. To benchmark the performance of the controller, the results of detailed noise studies and time-based imaging of the formation of ice layers on highly oriented pyrolytic graphite are shown.« less

  18. [Microbiological verification of a self control plan for a hospital food service].

    PubMed

    Torre, I; Pennino, F; Crispino, M

    2006-01-01

    During the past years, it has been an increment of food related infectious diseases. In order to avoid micro biological food contamination, adherence to good manufacturing is required through control measures of food safety practices. Updated national and European regulations underline the need to apply the HACCP system, overcoming the old concept of sample control on the end user product. This work shows results of microbiological controls made along the whole productive chain. Measurements are made using biomolecular techniques (PFGE) in order to assess the management of the micro biological risk of the self control plan applied to a hospital food service of Naples. The use of the PFGE applied on some micro-organisms gram negative potentially pathogen, underlines the circulation, continued in time, of these micro-organisms within the cooking area. In addition, cross contamination between several matrixes of samples has been detected.

  19. Sensitive Detection of Colorectal Cancer in Peripheral Blood by Septin 9 DNA Methylation Assay

    PubMed Central

    Grützmann, Robert; Molnar, Bela; Pilarsky, Christian; Habermann, Jens K.; Schlag, Peter M.; Saeger, Hans D.; Miehlke, Stephan; Stolz, Thomas; Model, Fabian; Roblick, Uwe J.; Bruch, Hans-Peter; Koch, Rainer; Liebenberg, Volker; deVos, Theo; Song, Xiaoling; Day, Robert H.; Sledziewski, Andrew Z.; Lofton-Day, Catherine

    2008-01-01

    Background Colorectal cancer (CRC) is the second leading cause of cancer deaths despite the fact that detection of this cancer in early stages results in over 90% survival rate. Currently less than 45% of at-risk individuals in the US are screened regularly, exposing a need for better screening tests. We performed two case-control studies to validate a blood-based test that identifies methylated DNA in plasma from all stages of CRC. Methodology/Principal Findings Using a PCR assay for analysis of Septin 9 (SEPT9) hypermethylation in DNA extracted from plasma, clinical performance was optimized on 354 samples (252 CRC, 102 controls) and validated in a blinded, independent study of 309 samples (126 CRC, 183 controls). 168 polyps and 411 additional disease controls were also evaluated. Based on the training study SEPT9-based classification detected 120/252 CRCs (48%) and 7/102 controls (7%). In the test study 73/126 CRCs (58%) and 18/183 control samples (10%) were positive for SEPT9 validating the training set results. Inclusion of an additional measurement replicate increased the sensitivity of the assay in the testing set to 72% (90/125 CRCs detected) while maintaining 90% specificity (19/183 for controls). Positive rates for plasmas from the other cancers (11/96) and non-cancerous conditions (41/315) were low. The rate of polyp detection (>1 cm) was ∼20%. Conclusions/Significance Analysis of SEPT9 DNA methylation in plasma represents a straightforward, minimally invasive method to detect all stages of CRC with potential to satisfy unmet needs for increased compliance in the screening population. Further clinical testing is warranted. PMID:19018278

  20. Ammonia concentrations in arterial blood, venous blood, and cerebrospinal fluid of dogs with and without congenital extrahepatic portosystemic shunts.

    PubMed

    Or, Matan; Devriendt, Nausikaa; Kitshoff, Adriaan M; Peremans, Kathelijne; Vandermeulen, Eva; Paepe, Dominique; Polis, Ingeborgh; Martlé, Valentine; de Rooster, Hilde

    2017-11-01

    OBJECTIVE To compare ammonia concentrations in arterial blood, venous blood, and CSF samples of dogs with and without extrahepatic portosystemic shunts (EHPSS). ANIMALS 19 dogs with congenital EHPSS and 6 healthy control dogs. PROCEDURES All dogs underwent a physical examination and then were anesthetized for transsplenic portal scintigraphy to confirm the presence or absence of EHPSS. While dogs were anesthetized, arterial and venous blood samples and a CSF sample were simultaneously collected for determination of ammonia concentration, which was measured by use of a portable blood ammonia analyzer (device A) and a nonportable biochemical analyzer (device B). Results were compared between dogs with EHPSS and control dogs. RESULTS Arterial, venous, and CSF ammonia concentrations for dogs with EHPSS were significantly greater than those for control dogs. For dogs with EHPSS, ammonia concentrations in both arterial and venous blood samples were markedly increased from the reference range. There was a strong positive correlation between arterial and venous ammonia concentrations and between blood (arterial or venous) and CSF ammonia concentrations. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that blood and CSF ammonia concentrations in dogs with EHPSS were greater than those for healthy dogs and were strongly and positively correlated, albeit in a nonlinear manner. This suggested that the permeability of the blood-brain barrier to ammonia may be abnormally increased in dogs with EHPSS, but further investigation of the relationship between blood or CSF ammonia concentration and clinical signs of hepatic encephalopathy or the surgical outcome for dogs with EHPSS is warranted.

  1. Development of a flow controller for long-term sampling of gases and vapors using evacuated canisters.

    PubMed

    Rossner, Alan; Farant, Jean Pierre; Simon, Philippe; Wick, David P

    2002-11-15

    Anthropogenic activities contribute to the release of a wide variety of volatile organic compounds (VOC) into microenvironments. Developing and implementing new air sampling technologies that allow for the characterization of exposures to VOC can be useful for evaluating environmental and health concerns arising from such occurrences. A novel air sampler based on the use of a capillary flow controller connected to evacuated canisters (300 mL, 1 and 6 L) was designed and tested. The capillary tube, used to control the flow of air, is a variation on a sharp-edge orifice flow controller. It essentially controls the velocity of the fluid (air) as a function of the properties of the fluid, tube diameter and length. A model to predict flow rate in this dynamic system was developed. The mathematical model presented here was developed using the Hagen-Poiseuille equation and the ideal gas law to predict flow into the canisters used to sample for long periods of time. The Hagen-Poiseuille equation shows the relationship between flow rate, pressure gradient, capillary resistance, fluid viscosity, capillary length and diameter. The flow rates evaluated were extremely low, ranging from 0.05 to 1 mL min(-1). The model was compared with experimental results and was shown to overestimate the flow rate. Empirical equations were developed to more accurately predict flow for the 300 mL, 1 and 6 L canisters used for sampling periods ranging from several hours to one month. The theoretical and observed flow rates for different capillary geometries were evaluated. Each capillary flow controller geometry that was tested was found to generate very reproducible results, RSD < 2%. Also, the empirical formulas developed to predict flow rate given a specified diameter and capillary length were found to predict flow rate within 6% of the experimental data. The samplers were exposed to a variety of airborne vapors that allowed for comparison of the effectiveness of capillary flow controllers to sorbent samplers and to an online gas chromatograph. The capillary flow controller was found to exceed the performance of the sorbent samplers in this comparison.

  2. Wavefront Control Testbed (WCT) Experiment Results

    NASA Technical Reports Server (NTRS)

    Burns, Laura A.; Basinger, Scott A.; Campion, Scott D.; Faust, Jessica A.; Feinberg, Lee D.; Hayden, William L.; Lowman, Andrew E.; Ohara, Catherine M.; Petrone, Peter P., III

    2004-01-01

    The Wavefront Control Testbed (WCT) was created to develop and test wavefront sensing and control algorithms and software for the segmented James Webb Space Telescope (JWST). Last year, we changed the system configuration from three sparse aperture segments to a filled aperture with three pie shaped segments. With this upgrade we have performed experiments on fine phasing with line-of-sight and segment-to-segment jitter, dispersed fringe visibility and grism angle;. high dynamic range tilt sensing; coarse phasing with large aberrations, and sampled sub-aperture testing. This paper reviews the results of these experiments.

  3. Cooking Chicken Breast Reduces Dialyzable Iron Resulting from Digestion of Muscle Proteins

    PubMed Central

    Gokhale, Aditya S.; Mahoney, Raymond R.

    2014-01-01

    The purpose of this research was to study the effect of cooking chicken breast on the production of dialyzable iron (an in vitro indicator of bioavailable iron) from added ferric iron. Chicken breast muscle was cooked by boiling, baking, sautéing, or deep-frying. Cooked samples were mixed with ferric iron and either extracted with acid or digested with pepsin and pancreatin. Total and ferrous dialyzable iron was measured after extraction or digestion and compared to raw chicken samples. For uncooked samples, dialyzable iron was significantly enhanced after both extraction and digestion. All cooking methods led to markedly reduced levels of dialyzable iron both by extraction and digestion. In most cooked, digested samples dialyzable iron was no greater than the iron-only (no sample) control. Cooked samples showed lower levels of histidine and sulfhydryls but protein digestibility was not reduced, except for the sautéed sample. The results showed that, after cooking, little if any dialyzable iron results from digestion of muscle proteins. Our research indicates that, in cooked chicken, residual acid-extractable components are the most important source of dialyzable iron. PMID:26904627

  4. Effect of Dephytinization by Fermentation and Hydrothermal Autoclaving Treatments on the Antioxidant Activity, Dietary Fiber, and Phenolic Content of Oat Bran.

    PubMed

    Özkaya, H; Özkaya, B; Duman, B; Turksoy, S

    2017-07-19

    Fermentation and hydrothermal methods were tested to reduce the phytic acid (PA) content of oat bran, and the effects of these methods on the dietary fiber (DF) and total phenolic (TP) contents as well as the antioxidant activity (AA) were also investigated. Fermentation with 6% yeast and for 6 h resulted in 88.2% reduction in PA content, while it only resulted in 32.5% reduction in the sample incubated for 6 h without yeast addition. The PA loss in autoclaved oat bran sample (1.5 h, pH 4.0) was 95.2% while it was 41.8% at most in the sample autoclaved without pH adjustment. In both methods, soluble, insoluble, and total DF contents of samples were remarkably higher than the control samples. Also for TP in the oat bran samples, both processes led to 17% and 39% increases, respectively, while AA values were 8% and 15%, respectively. Among all samples, the autoclaving process resulted in the lowest PA and the greatest amount of bioactive compounds.

  5. Cooking Chicken Breast Reduces Dialyzable Iron Resulting from Digestion of Muscle Proteins.

    PubMed

    Gokhale, Aditya S; Mahoney, Raymond R

    2014-01-01

    The purpose of this research was to study the effect of cooking chicken breast on the production of dialyzable iron (an in vitro indicator of bioavailable iron) from added ferric iron. Chicken breast muscle was cooked by boiling, baking, sautéing, or deep-frying. Cooked samples were mixed with ferric iron and either extracted with acid or digested with pepsin and pancreatin. Total and ferrous dialyzable iron was measured after extraction or digestion and compared to raw chicken samples. For uncooked samples, dialyzable iron was significantly enhanced after both extraction and digestion. All cooking methods led to markedly reduced levels of dialyzable iron both by extraction and digestion. In most cooked, digested samples dialyzable iron was no greater than the iron-only (no sample) control. Cooked samples showed lower levels of histidine and sulfhydryls but protein digestibility was not reduced, except for the sautéed sample. The results showed that, after cooking, little if any dialyzable iron results from digestion of muscle proteins. Our research indicates that, in cooked chicken, residual acid-extractable components are the most important source of dialyzable iron.

  6. Health-hazard evaluation report HETA 90-390-2065 and mHETA 86-012-2065, R. T. Vanderbilt Company, Gouverneur, New York and NIOSH comments to OSHA on Variations in the Carcinogenicity of Tremolite Dust Samples of Differing Morphology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, D.P.; Sanderson, W.; Fine, L.J.

    1990-09-01

    The testimony concerned the comments of NIOSH on a manuscript entitled Variations in the Carcinogenicity of Tremolite (77536686) Dust Samples of Differing Morphology. In general the results presented in the publication have not been peer reviewed or published in the scientific literature and therefore NIOSH suggested they be viewed with caution. Appropriate controls were not included in the study, the material and methods section lacked sufficient detail to evaluate the results, and the results were presented in an awkward and confusing way. The interpretation of results for the evidence of carcinogenicity in two of the samples was questionable. Mineralogic classificationmore » of the various samples, particularly three of the samples, was unclear. To what degree the nonasbestiform varieties of tremolite used in the study represent other varieties in the world was not clear. Dose-response relationships associated with fibers from these tremolite samples were not able to be developed. In general, the results appeared to demonstrate that all forms of tremolite asbestos should be considered carcinogenic.« less

  7. Sample Stimulus Control Shaping and Restricted Stimulus Control in Capuchin Monkeys: A Methodological Note

    ERIC Educational Resources Information Center

    Brino, Ana Leda F., Barros, Romariz S., Galvao, Ol; Garotti, M.; Da Cruz, Ilara R. N.; Santos, Jose R.; Dube, William V.; McIlvane, William J.

    2011-01-01

    This paper reports use of sample stimulus control shaping procedures to teach arbitrary matching-to-sample to 2 capuchin monkeys ("Cebus apella"). The procedures started with identity matching-to-sample. During shaping, stimulus features of the sample were altered gradually, rendering samples and comparisons increasingly physically dissimilar. The…

  8. Effects of computerized match-to-sample training on emergent fraction-decimal relations in individuals with fragile X syndrome.

    PubMed

    Hammond, Jennifer L; Hirt, Melissa; Hall, Scott S

    2012-01-01

    Individuals diagnosed with fragile X syndrome (FXS), the most common known form of inherited intellectual disability, are reported to exhibit considerable deficits in mathematical skills that are often attributed to brain-based abnormalities associated with the syndrome. We examined whether participants with FXS would display emergent fraction-decimal relations following brief, intensive match-to-sample training on baseline relations. The performance profiles on tests of symmetry and transitivity/equivalence of 11 participants with FXS, aged 10-23 years, following baseline match-to-sample training were compared to those of 11 age- and IQ-matched controls with idiopathic developmental disability. The results showed that both groups of participants showed significant improvements in the baseline (trained) relations, as expected. However, participants with FXS failed to show significant improvements in the (untrained) symmetry and transitivity/equivalence relations compared to those in the control group. A categorical analysis of the data indicated that five participants with FXS and eight controls showed at least "intermediate" emergence of symmetry relations, whereas one individual with FXS and three controls showed at least intermediate emergence of transitivity/equivalence relations. A correlation analysis of the data indicated that improvements in the symmetry relations were significantly associated with improvements in the transitivity/equivalence relations in the control group (r=.69, p=.018), but this was not the case in the FXS group (r=.34, p>.05). Participant IQ was significantly associated with improvements in the symmetry relations in individuals with FXS (r=.60, p=.049), but not in controls (r=.21, p>.05). Taken together, these results suggest that brief, computerized match-to-sample training may produce emergent mathematical relations for a subset of children with FXS and developmental disabilities. However, the ability of individuals with FXS to form transitivity/equivalence relations may be impaired relative to those with idiopathic developmental disabilities, which may be attributed to neurodevelopmental variables associated with the syndrome. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Measurement by ICP-MS of lead in plasma and whole blood of lead workers and controls.

    PubMed Central

    Schütz, A; Bergdahl, I A; Ekholm, A; Skerfving, S

    1996-01-01

    OBJECTIVES: To test a simple procedure for preparing samples for measurement of lead in blood plasma (P-Pb) and whole blood (B-Pb) by inductively coupled plasma mass spectrometry (ICP-MS), to measure P-Pb and B-Pb in lead workers and controls, and to evaluate any differences in the relation between B-Pb and P-Pb between people. METHODS: P-Pb and B-Pb were measured by ICP-MS in 43 male lead smelter workers and seven controls without occupational exposure to lead. For analysis, plasma and whole blood were diluted 1 in 4 and 1 in 9, respectively, with a diluted ammonia solution containing Triton-X 100 and EDTA. The samples were handled under routine laboratory conditions, without clean room facilities. RESULTS: P-Pb was measured with good precision (CV = 5%) even at concentrations present in the controls. Freeze storage of the samples had no effect on the results. The detection limit was 0.015 microgram/l. The P-Pb was 0.15 (range 0.1-0.3) microgram/l in controls and 1.2 (0.3-3.6) micrograms/l in lead workers, although the corresponding B-Pbs were 40 (24-59) micrograms/l and 281 (60-530) micrograms/l (1 microgram Pb/I = 4.8 nmol/l). B-Pb was closely associated with P-Pb (r = 0.90). The association was evidently non-linear; the ratio B-Pb/P-Pb decreased with increasing P-Pb. CONCLUSIONS: By means of ICP-MS and a simple dilution procedure, P-Pb may be measured accurately and with good precision down to concentrations present in controls. Contamination of blood at sampling and analysis is no major problem. With increasing P-Pb, the percentage of lead in plasma increases. In studies of lead toxicity, P-Pb should be considered as a complement to current indicators of lead exposure and risk. PMID:9038796

  10. Neurocognition and psychosocial functioning in adolescents with bipolar disorder.

    PubMed

    Best, Michael W; Bowie, Christopher R; Naiberg, Melanie R; Newton, Dwight F; Goldstein, Benjamin I

    2017-01-01

    Adults with bipolar disorder demonstrate significantly poorer psychosocial functioning and neurocognition compared to controls. In adult bipolar disorder neurocognition predicts a substantial portion of variance in functioning. Adolescents with bipolar disorder have reducedpsychosocial functioning, but less is known about neurocognitive impairments, and no studies have examined the relationship between neurocognition and functioning in an adolescent sample. 38 adolescents with bipolar disorder and 49 healthy controls under 20 years of age completed assessments of psychosocial functioning, neurocognitive ability, and psychiatric symptoms. Adolescents with bipolar disorder had significantly poorer psychosocial functioning in domains of daily activities, social functioning, and satisfaction with functioning, ps<.006, compared to healthy controls. They also had poorer general neurocognitive functioning than controls, p=.004, with the greatest impairment on a test of sustained attention. Neurocognition was not a significant predictor of psychosocial functioning in this sample, but depressive symptoms significantly predicted functioning in all domains, p<.033. Limited sample size did not allow for complex statistical analyses. Differences in demographic characteristics of the clinical and control groups may limit generalization of these results. This adolescent sample with bipolar disorder experiences significantly poorer neurocognitive and psychosocial functioning compared to controls; however, psychosocial functioning appears to be more strongly related to mood symptoms than to neurocognition. Future work is needed to delineate the time course of neurocognitive functioning and its relation to psychosocial functioning across the course of illness. Adolescence may provide an ideal time for cognitive enhancement and intensive psychosocial intervention. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Usage of DNA Fingerprinting Technology for Quality Control in Molecular Lab Bench Work.

    PubMed

    McIntosh, Linda Y; Lal, Janella E; Qin, Dahui

    2018-01-01

    One of the major quality assurance (QA) goals in many molecular laboratories is to avoid sample pipetting errors on the lab bench; especially when pipetting into multiwell plates. A pipetting error can cause a switch in patient samples, which can lead to recording the wrong results for the patient samples involved. Such pipetting errors are difficult to identify when it happens in lab bench work. DNA fingerprinting is a powerful tool in determining sample identities. Our laboratory has explored the usage of this technology in our QA process and successfully established that DNA fingerprinting can be used to monitor possible sample switch in gene rearrangement lab bench work. We use florescent light to quench the florescence in the gene rearrangement polymerase chain reaction products. After that, DNA fingerprinting technology is used to identify the sample DNA in the gene rearrangement polymerase chain reaction plate. The result is compared with the corresponding patient's blood sample DNA to determine whether there is a sample switch during the lab bench work.

  12. Grey matter, an endophenotype for schizophrenia? A voxel-based morphometry study in siblings of patients with schizophrenia.

    PubMed

    van der Velde, Jorien; Gromann, Paula M; Swart, Marte; de Haan, Lieuwe; Wiersma, Durk; Bruggeman, Richard; Krabbendam, Lydia; Aleman, André

    2015-05-01

    Grey matter, both volume and concentration, has been proposed as an endophenotype for schizophrenia given a number of reports of grey matter abnormalities in relatives of patients with schizophrenia. However, previous studies on grey matter abnormalities in relatives have produced inconsistent results. The aim of the present study was to examine grey matter differences between controls and siblings of patients with schizophrenia and to examine whether the age, genetic loading or subclinical psychotic symptoms of selected individuals could explain the previously reported inconsistencies. We compared the grey matter volume and grey matter concentration of healthy siblings of patients with schizophrenia and healthy controls matched for age, sex and education using voxel-based morphometry (VBM). Furthermore, we selected subsamples based on age (< 30 yr), genetic loading and subclinical psychotic symptoms to examine whether this would lead to different results. We included 89 siblings and 69 controls in our study. The results showed that siblings and controls did not differ significantly on grey matter volume or concentration. Furthermore, specifically selecting participants based on age, genetic loading or subclinical psychotic symptoms did not alter these findings. The main limitation was that subdividing the sample resulted in smaller samples for the subanalyses. Furthermore, we used MRI data from 2 different scanner sites. These results indicate that grey matter measured through VBM might not be a suitable endophenotype for schizophrenia.

  13. Performance of Bootstrapping Approaches To Model Test Statistics and Parameter Standard Error Estimation in Structural Equation Modeling.

    ERIC Educational Resources Information Center

    Nevitt, Jonathan; Hancock, Gregory R.

    2001-01-01

    Evaluated the bootstrap method under varying conditions of nonnormality, sample size, model specification, and number of bootstrap samples drawn from the resampling space. Results for the bootstrap suggest the resampling-based method may be conservative in its control over model rejections, thus having an impact on the statistical power associated…

  14. Fast and robust control of nanopositioning systems: Performance limits enabled by field programmable analog arrays.

    PubMed

    Baranwal, Mayank; Gorugantu, Ram S; Salapaka, Srinivasa M

    2015-08-01

    This paper aims at control design and its implementation for robust high-bandwidth precision (nanoscale) positioning systems. Even though modern model-based control theoretic designs for robust broadband high-resolution positioning have enabled orders of magnitude improvement in performance over existing model independent designs, their scope is severely limited by the inefficacies of digital implementation of the control designs. High-order control laws that result from model-based designs typically have to be approximated with reduced-order systems to facilitate digital implementation. Digital systems, even those that have very high sampling frequencies, provide low effective control bandwidth when implementing high-order systems. In this context, field programmable analog arrays (FPAAs) provide a good alternative to the use of digital-logic based processors since they enable very high implementation speeds, moreover with cheaper resources. The superior flexibility of digital systems in terms of the implementable mathematical and logical functions does not give significant edge over FPAAs when implementing linear dynamic control laws. In this paper, we pose the control design objectives for positioning systems in different configurations as optimal control problems and demonstrate significant improvements in performance when the resulting control laws are applied using FPAAs as opposed to their digital counterparts. An improvement of over 200% in positioning bandwidth is achieved over an earlier digital signal processor (DSP) based implementation for the same system and same control design, even when for the DSP-based system, the sampling frequency is about 100 times the desired positioning bandwidth.

  15. Light scattering by ultrasonically-controlled small particles: system design, calibration, and measurement results

    NASA Astrophysics Data System (ADS)

    Kassamakov, Ivan; Maconi, Göran; Penttilä, Antti; Helander, Petteri; Gritsevich, Maria; Puranen, Tuomas; Salmi, Ari; Hæggström, Edward; Muinonen, Karri

    2018-02-01

    We present the design of a novel scatterometer for precise measurement of the angular Mueller matrix profile of a mm- to µm-sized sample held in place by sound. The scatterometer comprises a tunable multimode Argon-krypton laser (with possibility to set 1 of the 12 wavelengths in visible range), linear polarizers, a reference photomultiplier tube (PMT) for monitoring the beam intensity, and a micro-PMT module mounted radially towards the sample at an adjustable radius. The measurement angle is controlled by a motor-driven rotation stage with an accuracy of 15'. The system is fully automated using LabVIEW, including the FPGA-based data acquisition and the instrument's user interface. The calibration protocol ensures accurate measurements by using a control sphere sample (diameter 3 mm, refractive index of 1.5) fixed first on a static holder followed by accurate multi-wavelength measurements of the same sample levitated ultrasonically. To demonstrate performance of the scatterometer, we conducted detailed measurements of light scattered by a particle derived from the Chelyabinsk meteorite, as well as planetary analogue materials. The measurements are the first of this kind, since they are obtained using controlled spectral angular scattering including linear polarization effects, for arbitrary shaped objects. Thus, our novel approach permits a non-destructive, disturbance-free measurement with control of the orientation and location of the scattering object.

  16. Examining the association between posttraumatic stress disorder and attention-deficit/hyperactivity disorder: a systematic review and meta-analysis.

    PubMed

    Spencer, Andrea E; Faraone, Stephen V; Bogucki, Olivia E; Pope, Amanda L; Uchida, Mai; Milad, Mohammed R; Spencer, Thomas J; Woodworth, K Yvonne; Biederman, Joseph

    2016-01-01

    To conduct a systematic review and meta-analysis examining the relationship between attention-deficit/hyperactivity disorder (ADHD) and posttraumatic stress disorder (PTSD). We reviewed literature through PubMed and PsycINFO without a specified date range, utilizing the search (posttraumatic stress disorder OR PTSD) AND (ADHD OR attention deficit hyperactivity disorder OR ADD OR attention deficit disorder OR hyperkinetic syndrome OR minimal brain dysfunction). References from relevant articles were reviewed. We identified 402 articles; 28 met criteria. We included original human research in English that operationalized diagnoses of ADHD and PTSD, evaluated the relationship between the disorders, and included controls. We excluded articles that failed to differentiate ADHD or PTSD from nonspecific or subsyndromal deficits or failed to compare their relationship. We extracted sample size, age, diagnostic methods, design, referral status, control type, and number of subjects with and without ADHD and PTSD alone and combined. We computed meta-analyses for 22 studies examining ADHD in PTSD and PTSD in ADHD using a random effects model and meta-analytic regression. We assessed for heterogeneity and publication bias and adjusted for intrastudy clustering. The relative risk (RR) for PTSD in ADHD was 2.9 (P < .0005); in samples using healthy controls, the RR was 3.7 (P = .001); and in samples using traumatized controls, the RR was 1.6 (P = .003). The RR for ADHD in PTSD was 1.7 (P < .0005); in samples using traumatized controls, the RR was 2.1 (P < .0005). The association was not significant in samples using psychiatric controls. Results indicate a bidirectional association between ADHD and PTSD, suggesting clinical implications and highlighting the need for neurobiological research that examines the mechanisms underlying this connection. © Copyright 2015 Physicians Postgraduate Press, Inc.

  17. Interaction of gases with lunar materials. [analysis of lunar samples from Apollo 17 flight

    NASA Technical Reports Server (NTRS)

    Holmes, H. F.; Fuller, E. L., Jr.; Gammage, R. B.

    1974-01-01

    The surface chemistry of Apollo 17 lunar fines samples 74220 (the orange soil) and 74241 (the gray control soil) has been studied by measuring the adsorption of nitrogen, argon, and oxygen (all at 77 K) and also water vapor (at 20 or 22 C). In agreement with results for samples from other missions, both samples had low initial specific surface areas, consisted of nonporous particles, and were attacked by water vapor at high relative pressure to give an increased specific surface area and create a pore system which gave rise to a capillary condensation hysteresis loop in the adsorption isotherms. In contrast to previous samples, both of the Apollo 17 soils were partially hydrophobic in their initial interaction with water vapor (both samples were completely hydrophilic after the reaction with water). The results are consistent with formation at high temperatures without subsequent exposure to significant amounts of water.

  18. 7 CFR 58.929 - Frequency of sampling for quality control.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Frequency of sampling for quality control. 58.929... Service 1 Operations and Operating Procedures § 58.929 Frequency of sampling for quality control. (a... to control composition. On continuous production runs, enough samples shall be taken throughout the...

  19. JSC Advanced Curation: Research and Development for Current Collections and Future Sample Return Mission Demands

    NASA Technical Reports Server (NTRS)

    Fries, M. D.; Allen, C. C.; Calaway, M. J.; Evans, C. A.; Stansbery, E. K.

    2015-01-01

    Curation of NASA's astromaterials sample collections is a demanding and evolving activity that supports valuable science from NASA missions for generations, long after the samples are returned to Earth. For example, NASA continues to loan hundreds of Apollo program samples to investigators every year and those samples are often analyzed using instruments that did not exist at the time of the Apollo missions themselves. The samples are curated in a manner that minimizes overall contamination, enabling clean, new high-sensitivity measurements and new science results over 40 years after their return to Earth. As our exploration of the Solar System progresses, upcoming and future NASA sample return missions will return new samples with stringent contamination control, sample environmental control, and Planetary Protection requirements. Therefore, an essential element of a healthy astromaterials curation program is a research and development (R&D) effort that characterizes and employs new technologies to maintain current collections and enable new missions - an Advanced Curation effort. JSC's Astromaterials Acquisition & Curation Office is continually performing Advanced Curation research, identifying and defining knowledge gaps about research, development, and validation/verification topics that are critical to support current and future NASA astromaterials sample collections. The following are highlighted knowledge gaps and research opportunities.

  20. The Marshall Islands Data Management Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stoker, A.C.; Conrado, C.L.

    1995-09-01

    This report is a resource document of the methods and procedures used currently in the Data Management Program of the Marshall Islands Dose Assessment and Radioecology Project. Since 1973, over 60,000 environmental samples have been collected. Our program includes relational database design, programming and maintenance; sample and information management; sample tracking; quality control; and data entry, evaluation and reduction. The usefulness of scientific databases involves careful planning in order to fulfill the requirements of any large research program. Compilation of scientific results requires consolidation of information from several databases, and incorporation of new information as it is generated. The successmore » in combining and organizing all radionuclide analysis, sample information and statistical results into a readily accessible form, is critical to our project.« less

Top