Moulin, Pauline; Patron, Kévin; Cano, Camille; Zorgani, Mohamed Amine; Camiade, Emilie; Borezée-Durant, Elise; Rosenau, Agnès; Mereghetti, Laurent
2016-01-01
ABSTRACT The Lmb protein of Streptococcus agalactiae is described as an adhesin that binds laminin, a component of the human extracellular matrix. In this study, we revealed a new role for this protein in zinc uptake. We also identified two Lmb homologs, AdcA and AdcAII, redundant binding proteins that combine with the AdcCB translocon to form a zinc-ABC transporter. Expression of this transporter is controlled by the zinc concentration in the medium through the zinc-dependent regulator AdcR. Triple deletion of lmb, adcA, and adcAII, or that of the adcCB genes, impaired growth and cell separation in a zinc-restricted environment. Moreover, we found that this Adc zinc-ABC transporter promotes S. agalactiae growth and survival in some human biological fluids, suggesting that it contributes to the infection process. These results indicated that zinc has biologically vital functions in S. agalactiae and that, under the conditions tested, the Adc/Lmb transporter constitutes the main zinc acquisition system of the bacterium. IMPORTANCE A zinc transporter, composed of three redundant binding proteins (Lmb, AdcA, and AdcAII), was characterized in Streptococcus agalactiae. This system was shown to be essential for bacterial growth and morphology in zinc-restricted environments, including human biological fluids. PMID:27672194
NASA Astrophysics Data System (ADS)
Ovchinnikov, M. Yu.; Ivanov, D. S.; Ivlev, N. A.; Karpenko, S. O.; Roldugin, D. S.; Tkachev, S. S.
2014-01-01
Design, analytical investigation, laboratory and in-flight testing of the attitude determination and control system (ADCS) of a microsatellites are considered. The system consists of three pairs of reaction wheels, three magnetorquers, a set of Sun sensors, a three-axis magnetometer and a control unit. The ADCS is designed for a small 10-50 kg LEO satellite. System development is accomplished in several steps: satellite dynamics preliminary study using asymptotical and numerical techniques, hardware and software design, laboratory testing of each actuator and sensor and the whole ADCS. Laboratory verification is carried out on the specially designed test-bench. In-flight ADCS exploitation results onboard the Russian microsatellite "Chibis-M" are presented. The satellite was developed, designed and manufactured by the Institute of Space Research of RAS. "Chibis-M" was launched by the "Progress-13M" cargo vehicle on January 25, 2012 after undocking from the International Space Station (ISS). This paper assess both the satellite and the ADCS mock-up dynamics. Analytical, numerical and laboratory study results are in good correspondence with in-flight data.
Moulin, Pauline; Patron, Kévin; Cano, Camille; Zorgani, Mohamed Amine; Camiade, Emilie; Borezée-Durant, Elise; Rosenau, Agnès; Mereghetti, Laurent; Hiron, Aurélia
2016-12-15
The Lmb protein of Streptococcus agalactiae is described as an adhesin that binds laminin, a component of the human extracellular matrix. In this study, we revealed a new role for this protein in zinc uptake. We also identified two Lmb homologs, AdcA and AdcAII, redundant binding proteins that combine with the AdcCB translocon to form a zinc-ABC transporter. Expression of this transporter is controlled by the zinc concentration in the medium through the zinc-dependent regulator AdcR. Triple deletion of lmb, adcA, and adcAII, or that of the adcCB genes, impaired growth and cell separation in a zinc-restricted environment. Moreover, we found that this Adc zinc-ABC transporter promotes S. agalactiae growth and survival in some human biological fluids, suggesting that it contributes to the infection process. These results indicated that zinc has biologically vital functions in S. agalactiae and that, under the conditions tested, the Adc/Lmb transporter constitutes the main zinc acquisition system of the bacterium. A zinc transporter, composed of three redundant binding proteins (Lmb, AdcA, and AdcAII), was characterized in Streptococcus agalactiae This system was shown to be essential for bacterial growth and morphology in zinc-restricted environments, including human biological fluids. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
12-bit 32 channel 500 MS/s low-latency ADC for particle accelerators real-time control
NASA Astrophysics Data System (ADS)
Karnitski, Anton; Baranauskas, Dalius; Zelenin, Denis; Baranauskas, Gytis; Zhankevich, Alexander; Gill, Chris
2017-09-01
Particle beam control systems require real-time low latency digital feedback with high linearity and dynamic range. Densely packed electronic systems employ high performance multichannel digitizers causing excessive heat dissipation. Therefore, low power dissipation is another critical requirement for these digitizers. A described 12-bit 500 MS/s ADC employs a sub-ranging architecture based on a merged sample & hold circuit, a residue C-DAC and a shared 6-bit flash core ADC. The core ADC provides a sequential coarse and fine digitization featuring a latency of two clock cycles. The ADC is implemented in a 28 nm CMOS process and consumes 4 mW of power per channel from a 0.9 V supply (interfacing and peripheral circuits are excluded). Reduced power consumption and small on-chip area permits the implementation of 32 ADC channels on a 10.7 mm2 chip. The ADC includes a JESD204B standard compliant output data interface operated at the 7.5 Gbps/ch rate. To minimize the data interface related time latency, a special feature permitting to bypass the JESD204B interface is built in. DoE Phase I Award Number: DE-SC0017213.
Implementation of Advanced Inventory Management Functionality in Automated Dispensing Cabinets
Webb, Aaron; Lund, Jim
2015-01-01
Background: Automated dispensing cabinets (ADCs) are an integral component of distribution models in pharmacy departments across the country. There are significant challenges to optimizing ADC inventory management while minimizing use of labor and capital resources. The role of enhanced inventory control functionality is not fully defined. Objective: The aim of this project is to improve ADC inventory management by leveraging dynamic inventory standards and a low inventory alert platform. Methods: Two interventional groups and 1 historical control were included in the study. Each intervention group consisted of 6 ADCs that tested enhanced inventory management functionality. Interventions included dynamic inventory standards and a low inventory alert messaging system. Following separate implementation of each platform, dynamic inventory and low inventory alert systems were applied concurrently to all 12 ADCs. Outcome measures included number and duration of daily stockouts, ADC inventory turns, and number of phone calls related to stockouts received by pharmacy staff. Results: Low inventory alerts reduced both the number and duration of stockouts. Dynamic inventory standards reduced the number of daily stockouts without changing the inventory turns and duration of stockouts. No change was observed in number of calls related to stockouts made to pharmacy staff. Conclusions: Low inventory alerts and dynamic inventory standards are feasible mechanisms to help optimize ADC inventory management while minimizing labor and capital resources. PMID:26448672
MR Scanner Systems Should Be Adequately Characterized in Diffusion-MRI of the Breast
Giannelli, Marco; Sghedoni, Roberto; Iacconi, Chiara; Iori, Mauro; Traino, Antonio Claudio; Guerrisi, Maria; Mascalchi, Mario; Toschi, Nicola; Diciotti, Stefano
2014-01-01
Breast imaging represents a relatively recent and promising field of application of quantitative diffusion-MRI techniques. In view of the importance of guaranteeing and assessing its reliability in clinical as well as research settings, the aim of this study was to specifically characterize how the main MR scanner system-related factors affect quantitative measurements in diffusion-MRI of the breast. In particular, phantom acquisitions were performed on three 1.5 T MR scanner systems by different manufacturers, all equipped with a dedicated multi-channel breast coil as well as acquisition sequences for diffusion-MRI of the breast. We assessed the accuracy, inter-scan and inter-scanner reproducibility of the mean apparent diffusion coefficient measured along the main orthogonal directions (
Brenn, B Randall; Kim, Margaret A; Hilmas, Elora
2015-08-15
Development of an operational reporting dashboard designed to correlate data from multiple sources to help detect potential drug diversion by automated dispensing cabinet (ADC) users is described. A commercial business intelligence platform was used to create a dashboard tool for rapid detection of unusual patterns of ADC transactions by anesthesia service providers at a large pediatric hospital. By linking information from the hospital's pharmacy information management system (PIMS) and anesthesia information management system (AIMS) in an associative data model, the "narcotic reconciliation dashboard" can generate various reports to help spot outlier activity associated with ADC dispensing of controlled substances and documentation of medication waste processing. The dashboard's utility was evaluated by "back-testing" the program with historical data on an actual episode of diversion by an anesthesia provider that had not been detected through traditional methods of PIMS and AIMS data monitoring. Dashboard-generated reports on key metrics (e.g., ADC transaction counts, discrepancies in dispensed versus reconciled amounts of narcotics, PIMS-AIMS documentation mismatches) over various time frames during the period of known diversion clearly indicated the diverter's outlier status relative to other authorized ADC users. A dashboard program for correlating ADC transaction data with pharmacy and patient care data may be an effective tool for detecting patterns of ADC use that suggest drug diversion. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Implementation and optimization of automated dispensing cabinet technology.
McCarthy, Bryan C; Ferker, Michael
2016-10-01
A multifaceted automated dispensing cabinet (ADC) optimization initiative at a large hospital is described. The ADC optimization project, which was launched approximately six weeks after activation of ADCs in 30 patient care unit medication rooms of a newly established adult hospital, included (1) adjustment of par inventory levels (desired on-hand quantities of medications) and par reorder quantities to reduce the risk of ADC supply exhaustion and improve restocking efficiency, (2) expansion of ADC "common stock" (medications assigned to ADC inventories) to increase medication availability at the point of care, and (3) removal of some infrequently prescribed medications from ADCs to reduce the likelihood of product expiration. The purpose of the project was to address organizational concerns regarding widespread ADC medication stockouts, growing reliance on cart-fill medication delivery systems, and suboptimal medication order turnaround times. Leveraging of the ADC technology platform's reporting functionalities for enhanced inventory control yielded a number of benefits, including cost savings resulting from reduced pharmacy technician labor requirements (estimated at $2,728 annually), a substantial reduction in the overall weekly stockout percentage (from 3.2% before optimization to 0.5% eight months after optimization), an improvement in the average medication turnaround time, and estimated cost avoidance of $19,660 attributed to the reduced potential for product expiration. Efforts to optimize ADCs through par level optimization, expansion of common stock, and removal of infrequently used medications reduced pharmacy technician labor, decreased stockout percentages, generated opportunities for cost avoidance, and improved medication turnaround times. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Analysis and correction of gradient nonlinearity bias in ADC measurements
Malyarenko, Dariya I.; Ross, Brian D.; Chenevert, Thomas L.
2013-01-01
Purpose Gradient nonlinearity of MRI systems leads to spatially-dependent b-values and consequently high non-uniformity errors (10–20%) in ADC measurements over clinically relevant field-of-views. This work seeks practical correction procedure that effectively reduces observed ADC bias for media of arbitrary anisotropy in the fewest measurements. Methods All-inclusive bias analysis considers spatial and time-domain cross-terms for diffusion and imaging gradients. The proposed correction is based on rotation of the gradient nonlinearity tensor into the diffusion gradient frame where spatial bias of b-matrix can be approximated by its Euclidean norm. Correction efficiency of the proposed procedure is numerically evaluated for a range of model diffusion tensor anisotropies and orientations. Results Spatial dependence of nonlinearity correction terms accounts for the bulk (75–95%) of ADC bias for FA = 0.3–0.9. Residual ADC non-uniformity errors are amplified for anisotropic diffusion. This approximation obviates need for full diffusion tensor measurement and diagonalization to derive a corrected ADC. Practical scenarios are outlined for implementation of the correction on clinical MRI systems. Conclusions The proposed simplified correction algorithm appears sufficient to control ADC non-uniformity errors in clinical studies using three orthogonal diffusion measurements. The most efficient reduction of ADC bias for anisotropic medium is achieved with non-lab-based diffusion gradients. PMID:23794533
FPGA Flash Memory High Speed Data Acquisition
NASA Technical Reports Server (NTRS)
Gonzalez, April
2013-01-01
The purpose of this research is to design and implement a VHDL ONFI Controller module for a Modular Instrumentation System. The goal of the Modular Instrumentation System will be to have a low power device that will store data and send the data at a low speed to a processor. The benefit of such a system will give an advantage over other purchased binary IP due to the capability of allowing NASA to re-use and modify the memory controller module. To accomplish the performance criteria of a low power system, an in house auxiliary board (Flash/ADC board), FPGA development kit, debug board, and modular instrumentation board will be jointly used for the data acquisition. The Flash/ADC board contains four, 1 MSPS, input channel signals and an Open NAND Flash memory module with an analog to digital converter. The ADC, data bits, and control line signals from the board are sent to an Microsemi/Actel FPGA development kit for VHDL programming of the flash memory WRITE, READ, READ STATUS, ERASE, and RESET operation waveforms using Libero software. The debug board will be used for verification of the analog input signal and be able to communicate via serial interface with the module instrumentation. The scope of the new controller module was to find and develop an ONFI controller with the debug board layout designed and completed for manufacture. Successful flash memory operation waveform test routines were completed, simulated, and tested to work on the FPGA board. Through connection of the Flash/ADC board with the FPGA, it was found that the device specifications were not being meet with Vdd reaching half of its voltage. Further testing showed that it was the manufactured Flash/ADC board that contained a misalignment with the ONFI memory module traces. The errors proved to be too great to fix in the time limit set for the project.
NASA Astrophysics Data System (ADS)
Nakasuka, Shinichi; Miyata, Kikuko; Tsuruda, Yoshihiro; Aoyanagi, Yoshihide; Matsumoto, Takeshi
2018-04-01
The recent advancement of micro/nano/pico-satellites technologies encourages many universities to develop three axis stabilized satellites. As three axis stabilization is high level technology requiring the proper functioning of various sensors, actuators and control software, many early satellites failed in their initial operation phase because of shortage of solar power generation or inability to realize the initial step of missions because of unexpected attitude control system performance. These results come from failure to design the satellite attitude determination and control system (ADCS) appropriately and not considering "satellite survivability." ADCS should be designed such that even if some sensors or actuators cannot work as expected, the satellite can survive and carry out some of its missions, even if not full. This paper discusses how to realize ADCS while taking satellite survivability into account, based on our experiences of design and in-orbit operations of Hodoyoshi-3 and 4 satellites launched in 2014, which suffered from various component anomalies but could complete their missions.
Adjustable Nyquist-rate System for Single-Bit Sigma-Delta ADC with Alternative FIR Architecture
NASA Astrophysics Data System (ADS)
Frick, Vincent; Dadouche, Foudil; Berviller, Hervé
2016-09-01
This paper presents a new smart and compact system dedicated to control the output sampling frequency of an analogue-to-digital converters (ADC) based on single-bit sigma-delta (ΣΔ) modulator. This system dramatically improves the spectral analysis capabilities of power network analysers (power meters) by adjusting the ADC's sampling frequency to the input signal's fundamental frequency with a few parts per million accuracy. The trade-off between straightforwardness and performance that motivated the choice of the ADC's architecture are preliminary discussed. It particularly comes along with design considerations of an ultra-steep direct-form FIR that is optimised in terms of size and operating speed. Thanks to compact standard VHDL language description, the architecture of the proposed system is particularly suitable for application-specific integrated circuit (ASIC) implementation-oriented low-power and low-cost power meter applications. Field programmable gate array (FPGA) prototyping and experimental results validate the adjustable sampling frequency concept. They also show that the system can perform better in terms of implementation and power capabilities compared to dedicated IP resources.
Thermostatic system of sensor in NIR spectrometer based on PID control
NASA Astrophysics Data System (ADS)
Wang, Zhihong; Qiao, Liwei; Ji, Xufei
2016-11-01
Aiming at the shortcomings of the primary sensor thermostatic control system in the near infrared (NIR) spectrometer, a novel thermostatic control system based on proportional-integral-derivative (PID) control technology was developed to improve the detection precision of the NIR spectrometer. There were five parts including bridge amplifier circuit, analog-digital conversion (ADC) circuit, microcontroller, digital-analog conversion (DAC) circuit and drive circuit in the system. The five parts formed a closed-loop control system based on PID algorithm that was used to control the error between the temperature calculated by the sampling data of ADC and the designed temperature to ensure the stability of the spectrometer's sensor. The experimental results show that, when the operating temperature of sensor is -11°, compared with the original system, the temperature control precision of the new control system is improved from ±0.64° to ±0.04° and the spectrum signal to noise ratio (SNR) is improved from 4891 to 5967.
Malyarenko, Dariya I; Ross, Brian D; Chenevert, Thomas L
2014-03-01
Gradient nonlinearity of MRI systems leads to spatially dependent b-values and consequently high non-uniformity errors (10-20%) in apparent diffusion coefficient (ADC) measurements over clinically relevant field-of-views. This work seeks practical correction procedure that effectively reduces observed ADC bias for media of arbitrary anisotropy in the fewest measurements. All-inclusive bias analysis considers spatial and time-domain cross-terms for diffusion and imaging gradients. The proposed correction is based on rotation of the gradient nonlinearity tensor into the diffusion gradient frame where spatial bias of b-matrix can be approximated by its Euclidean norm. Correction efficiency of the proposed procedure is numerically evaluated for a range of model diffusion tensor anisotropies and orientations. Spatial dependence of nonlinearity correction terms accounts for the bulk (75-95%) of ADC bias for FA = 0.3-0.9. Residual ADC non-uniformity errors are amplified for anisotropic diffusion. This approximation obviates need for full diffusion tensor measurement and diagonalization to derive a corrected ADC. Practical scenarios are outlined for implementation of the correction on clinical MRI systems. The proposed simplified correction algorithm appears sufficient to control ADC non-uniformity errors in clinical studies using three orthogonal diffusion measurements. The most efficient reduction of ADC bias for anisotropic medium is achieved with non-lab-based diffusion gradients. Copyright © 2013 Wiley Periodicals, Inc.
Integrated mixed signal control IC for 500-kHz switching frequency buck regulator
NASA Astrophysics Data System (ADS)
Chen, Keng; Zhang, Hong
2015-12-01
The main purpose for this work is to study the challenges of designing a digital buck regulator using pipelined analog to digital converter (ADC). Although pipelined ADC can achieve high sampling speed, it will introduce additional phase lag to the buck circuit. Along with the latency brought by processing time of additional digital circuits, as well as the time delay associated with the switching frequency, the closed loop will be unstable; moreover, raw ADC outputs have low signal-to-noise ratio, which usually need back-end calibration. In order to compensate these phase lag and make control loop unconditional stable, as well as boost up signal-to-noise ratio of the ADC block with cost-efficient design, a finite impulse response filter followed by digital proportional-integral-derivative blocks were designed. All these digital function blocks were optimised with processing speed. In the system simulation, it can be found that this controller achieved output regulation within 10% of nominal 5 V output voltage under 1 A/µs load transient condition; moreover, with the soft-start method, there is no turn-on overshooting. The die size of this controller is controlled within 3 mm2 by using 180 nm CMOS technology.
Converting the Active Digital Controller for Use in Two Tests
NASA Technical Reports Server (NTRS)
Wright, Robert G.
1995-01-01
The Active Digital Controller is a system used to control the various functions of wind tunnel models. It has the capability of digitizing and saving of up to sixty-four channels of analog data. It can output up to 16 channels of analog command signals. In addition to its use as a general controller, it can run up to two distinct control laws. All of this is done at a regulated speed of two hundred hertz. The Active Digital Controller (ADC) was modified for use in the Actively Controlled Response of Buffet Affected Tails (ACROBAT) tests and for side-wall pressure data acquisition. The changes included general maintenance and updating of the controller as well as setting up special modes of operation. The ACROBAT tests required that two sets of output signals be available. The pressure data acquisition needed a sampling rate of four hundred hertz, twice the standard ADC rate. These modifications were carried out and the ADC was used during the ACROBAT wind tunnel entry.
A reconfigurable medically cohesive biomedical front-end with ΣΔ ADC in 0.18µm CMOS.
Jha, Pankaj; Patra, Pravanjan; Naik, Jairaj; Acharya, Amit; Rajalakshmi, P; Singh, Shiv Govind; Dutta, Ashudeb
2015-08-01
This paper presents a generic programmable analog front-end (AFE) for acquisition and digitization of various biopotential signals. This includes a lead-off detection circuit, an ultra-low current capacitively coupled signal conditioning stage with programmable gain and bandwidth, a new mixed signal automatic gain control (AGC) mechanism and a medically cohesive reconfigurable ΣΔ ADC. The full system is designed in UMC 0.18μm CMOS. The AFE achieves an overall linearity of more 10 bits with 0.47μW power consumption. The ADC provides 2(nd) order noise-shaping while using single integrator and an ENOB of ~11 bits with 5μW power consumption. The system was successfully verified for various ECG signals from PTB database. This system is intended for portable batteryless u-Healthcare devices.
Idiopathic normal-pressure hydrocephalus: temporal changes in ADC during cardiac cycle.
Ohno, Naoki; Miyati, Tosiaki; Mase, Mitsuhito; Osawa, Tomoshi; Kan, Hirohito; Kasai, Harumasa; Hara, Masaki; Shibamoto, Yuta; Hayashi, Norio; Gabata, Toshifumi; Matsui, Osamu
2011-11-01
To determine whether temporal changes in apparent diffusion coefficient (ADC) over the cardiac cycle are different in patients with idiopathic normal-pressure hydrocephalus (INPH) as compared with patients with ex vacuo ventricular dilatation and healthy control subjects. This prospective study was approved by the institutional review board and was performed only after informed consent was obtained from each patient. At 1.5 T, electrocardiographically triggered single-shot diffusion echo-planar magnetic resonance imaging (b = 0 and 1000 sec/mm(2)) was performed with sensitivity encoding and half-scan techniques to minimize bulk motion. ΔADC was defined as the difference between maximum and minimum ADC on a pixel-by-pixel basis over 20 phases of the cardiac cycle. Mean ADC during the diastolic phase and ΔADC in the frontal white matter were determined in patients with INPH (n = 13), patients with ex vacuo ventricular dilatation (n = 8), and healthy volunteers (n = 10). Kruskal-Wallis tests were used to determine significance between groups. Mean ΔADC in the INPH group was significantly higher than that in the ex vacuo ventricular dilatation and control groups (P < .01 for both). There was no significant difference in ΔADC between the ex vacuo ventricular dilatation and control groups (P = .86). There was no significant difference in mean ADC during the diastolic phase among groups (P > .05 for all). There was no significant correlation between ΔADC and mean ADC during the diastolic phase in any group. Determination of fluctuation of ADC over the cardiac cycle may render it possible to noninvasively obtain new and more detailed information than that provided by standard ADC measurement in suspected INPH, potentially facilitating the diagnosis of this disease. RSNA, 2011
Lin, Yuning; Li, Hui; Chen, Ziqian; Ni, Ping; Zhong, Qun; Huang, Huijuan; Sandrasegaran, Kumar
2015-05-01
The purpose of this study was to investigate the application of histogram analysis of apparent diffusion coefficient (ADC) in characterizing pathologic features of cervical cancer and benign cervical lesions. This prospective study was approved by the institutional review board, and written informed consent was obtained. Seventy-three patients with cervical cancer (33-69 years old; 35 patients with International Federation of Gynecology and Obstetrics stage IB cervical cancer) and 38 patients (38-61 years old) with normal cervix or cervical benign lesions (control group) were enrolled. All patients underwent 3-T diffusion-weighted imaging (DWI) with b values of 0 and 800 s/mm(2). ADC values of the entire tumor in the patient group and the whole cervix volume in the control group were assessed. Mean ADC, median ADC, 25th and 75th percentiles of ADC, skewness, and kurtosis were calculated. Histogram parameters were compared between different pathologic features, as well as between stage IB cervical cancer and control groups. Mean ADC, median ADC, and 25th percentile of ADC were significantly higher for adenocarcinoma (p = 0.021, 0.006, and 0.004, respectively), and skewness was significantly higher for squamous cell carcinoma (p = 0.011). Median ADC was statistically significantly higher for well or moderately differentiated tumors (p = 0.044), and skewness was statistically significantly higher for poorly differentiated tumors (p = 0.004). No statistically significant difference of ADC histogram was observed between lymphovascular space invasion subgroups. All histogram parameters differed significantly between stage IB cervical cancer and control groups (p < 0.05). Distribution of ADCs characterized by histogram analysis may help to distinguish early-stage cervical cancer from normal cervix or cervical benign lesions and may be useful for evaluating the different pathologic features of cervical cancer.
Investigation of Metabolomic Blood Biomarkers for Detection of Adenocarcinoma Lung Cancer
Fahrmann, Johannes F.; Kim, Kyoungmi; DeFelice, Brian C.; Taylor, Sandra L.; Gandara, David R.; Yoneda, Ken Y.; Cooke, David T.; Fiehn, Oliver; Kelly, Karen; Miyamoto, Suzanne
2015-01-01
Background Untargeted metabolomics was utilized in case control studies of adenocarcinoma (ADC) lung cancer in order to develop and test metabolite classifiers in serum and plasma as potential biomarkers for diagnosing lung cancer. Methods Serum and plasma were collected and used in two independent case-control studies (ADC1 and ADC2). Controls were frequency matched for gender, age and smoking history. There were 52 ADC cases and 31 controls in ADC1 and 43 ADC cases and 43 controls in ADC2. Metabolomics was conducted using gas chromatography time-of-flight mass spectrometry. Differential analysis was performed on ADC1 and the top candidates (FDR < 0.05) for serum and plasma used to develop individual and multiplex-classifiers that were then tested on an independent set of serum and plasma samples (ADC2). Results Aspartate provided the best accuracy (81.4%) for an individual metabolite classifier in serum whereas pyrophosphate had the best accuracy (77.9%) in plasma when independently tested. Multiplex classifiers of either 2 or 4 serum metabolites had an accuracy of 72.7% when independently tested. For plasma, a multi-metabolite classifier consisting of 8 metabolites gave an accuracy of 77.3% when independently tested. Comparison of overall diagnostic performance between the two blood matrices yielded similar performances. However, serum is most ideal given higher sensitivity for low abundant metabolites. Conclusion This study shows the potential of metabolite-based diagnostic tests for detection of lung adenocarcinoma. Further validation in a larger pool of samples is warranted. Impact These biomarkers could improve early detection and diagnosis of lung cancer. PMID:26282632
Liu, Xilin; Zhang, Milin; Richardson, Andrew G; Lucas, Timothy H; Van der Spiegel, Jan
2017-08-01
This paper presents a bidirectional brain machine interface (BMI) microsystem designed for closed-loop neuroscience research, especially experiments in freely behaving animals. The system-on-chip (SoC) consists of 16-channel neural recording front-ends, neural feature extraction units, 16-channel programmable neural stimulator back-ends, in-channel programmable closed-loop controllers, global analog-digital converters (ADC), and peripheral circuits. The proposed neural feature extraction units includes 1) an ultra low-power neural energy extraction unit enabling a 64-step natural logarithmic domain frequency tuning, and 2) a current-mode action potential (AP) detection unit with time-amplitude window discriminator. A programmable proportional-integral-derivative (PID) controller has been integrated in each channel enabling a various of closed-loop operations. The implemented ADCs include a 10-bit voltage-mode successive approximation register (SAR) ADC for the digitization of the neural feature outputs and/or local field potential (LFP) outputs, and an 8-bit current-mode SAR ADC for the digitization of the action potential outputs. The multi-mode stimulator can be programmed to perform monopolar or bipolar, symmetrical or asymmetrical charge balanced stimulation with a maximum current of 4 mA in an arbitrary channel configuration. The chip has been fabricated in 0.18 μ m CMOS technology, occupying a silicon area of 3.7 mm 2 . The chip dissipates 56 μW/ch on average. General purpose low-power microcontroller with Bluetooth module are integrated in the system to provide wireless link and SoC configuration. Methods, circuit techniques and system topology proposed in this work can be used in a wide range of relevant neurophysiology research, especially closed-loop BMI experiments.
Mabbott, Donald J; Noseworthy, Michael D; Bouffet, Eric; Rockel, Conrad; Laughlin, Suzanne
2006-07-01
Treatment of children with cranial-spinal radiation (CSR) for brain tumors is associated with adverse intellectual outcome and white matter damage. However, the correlation between IQ and measures of white matter integrity has received little attention. We examined apparent diffusion coefficient (ADC), fractional anisotropy (FA), and intelligence in pediatric patients treated with CSR for medulloblastoma relative to control subjects. ADC and FA measures were obtained for eight patients and eight control children and evaluated in multiple regions of interest in the cerebral hemispheres. Mean ADC and mean FA for each region were calculated, group differences were evaluated, and the relationship between these measures and intelligence were examined. In our study group, decreased IQ was associated with increased ADC and decreased FA (P < 0.01). Mean IQ for the CSR group was lower than that for the control group, but the difference was not significant when controlling for overall mean FA or ADC (P > 0.10). Overall mean FA was lower and ADC was higher in the CSR group relative to controls (P < 0.01). Specifically, FA was lower in the genu of the corpus callosum, the anterior and posterior limbs of the internal capsule, inferior frontal white matter, and high frontal white matter, and ADC was higher in all regions in patients relative to controls (P < 0.01). Compromised white matter integrity was observed for multiple regions within the cerebral hemispheres following CSR. A novel finding was that microscopic damage in normal-appearing white matter, as indexed by higher ADC and lower FA, was related to poor intellectual outcome relative to age-matched controls.
Li, Gui Dian; Liang, Ying Yin; Xu, Ping; Ling, Jian; Chen, Ying Ming
2016-04-01
The purpose of this study is to investigate the correlation of apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values with fatty infiltration in the thigh muscles of patients with Duchenne muscular dystrophy (DMD) using diffusion-tensor imaging (DTI). Twenty-one boys with DMD were recruited. The grade of fatty infiltration and the ADC and FA values of four thigh muscles (rectus femoris, semitendinosus, sartorius, and gracilis) were measured, and the FA and ADC values were compared with the grade of fatty infiltration. Twenty age-matched healthy boys were enrolled as the control group. The differences in the ADC and FA values of the thigh muscles between patients with DMD and the control group were compared. The patients with DMD showed lower FA values and higher ADC values in all measured muscles when compared with the control group. The FA and ADC values were correlated with the grade of fatty infiltration. For the rectus femoris muscle, r = -0.753 and p = 0.007 for FA, and r = 0.685 and p = 0.001 for ADC. For the semitendinosus muscle, r = -0.621 and p = 0.041 for FA, and r = 0.705 and p = 0.021 for ADC. For the sartorius muscle, r = -0.662 and p = 0.027 for FA, and r = 0.701 and p = 0.017 for ADC. For the gracilis muscle, r = -0.618 and p = 0.043 for FA, and r = 0.695 and p = 0.022 for ADC. Damage to the thigh muscles in patients with DMD can be detected by ADC and FA values using DTI. DTI can be used to assess the severity of the disease.
Wang, Yu; Zhang, Heng; Zhang, Ruzhi; Zhao, Zhoushe; Xu, Ziqian; Wang, Lei; Liu, Rongbo; Gao, Fabao
2017-01-01
To assess kidney damage in a rat model of type-2 diabetic nephropathy based on apparent diffusion coefficient (ADC) data obtained from ultra-high b-values and discuss its relationship to the expression of aquaporins (AQPs). This study was approved by the institutional Animal Care and Use Committee. Thirty male Sprague-Dawley rats were randomised into two groups: (1) untreated controls and (2) diabetes mellitus (DM). All rats underwent diffusion-weighted imaging (DWI) with 18 b-values (0-4500 s/mm 2 ). Maps of low ADC (ADC low ), standard ADC (ADC st ) and ultra-high ADC (ADC uh ) were calculated from low b-values (0-200 s/mm 2 ), standard b-values (300-1500 s/mm 2 ) and ultra-high b-values (1700-4500 s/mm 2 ), respectively. The expression of AQPs in the kidneys was studied using immunohistochemistry. Laboratory parameters of diabetic and kidney functions, ADC low , ADC st , ADC uh , and the optical density (OD) of AQP expression in the two groups were compared using an independent t test. Correlations between ADCs and the OD of AQP expression were evaluated by Pearson's correlation analysis. ADC uh were significantly higher in the cortex (CO), outer stripe of the outer medulla (OS) and inner stripe of the outer medulla (IS), and the OD values of AQ-2 were significantly higher in the OS, IS and inner medulla (IM) in DM animals compared with control animals. ADC uh and OD values of AQP-2 expression were positively correlated in the OS, IS and IM of the kidney. ADC uh may work as useful metrics for early detection of kidney damage in diabetic nephropathy and may be associated with AQP-2 expression.
Doblas, Sabrina; Almeida, Gilberto S; Blé, François-Xavier; Garteiser, Philippe; Hoff, Benjamin A; McIntyre, Dominick J O; Wachsmuth, Lydia; Chenevert, Thomas L; Faber, Cornelius; Griffiths, John R; Jacobs, Andreas H; Morris, David M; O'Connor, James P B; Robinson, Simon P; Van Beers, Bernard E; Waterton, John C
2015-12-01
To evaluate between-site agreement of apparent diffusion coefficient (ADC) measurements in preclinical magnetic resonance imaging (MRI) systems. A miniaturized thermally stable ice-water phantom was devised. ADC (mean and interquartile range) was measured over several days, on 4.7T, 7T, and 9.4T Bruker, Agilent, and Magnex small-animal MRI systems using a common protocol across seven sites. Day-to-day repeatability was expressed as percent variation of mean ADC between acquisitions. Cross-site reproducibility was expressed as 1.96 × standard deviation of percent deviation of ADC values. ADC measurements were equivalent across all seven sites with a cross-site ADC reproducibility of 6.3%. Mean day-to-day repeatability of ADC measurements was 2.3%, and no site was identified as presenting different measurements than others (analysis of variance [ANOVA] P = 0.02, post-hoc test n.s.). Between-slice ADC variability was negligible and similar between sites (P = 0.15). Mean within-region-of-interest ADC variability was 5.5%, with one site presenting a significantly greater variation than the others (P = 0.0013). Absolute ADC values in preclinical studies are comparable between sites and equipment, provided standardized protocols are employed. © 2015 Wiley Periodicals, Inc.
Antiretroviral Therapy and Central Nervous System HIV-1 Infection
Price, Richard W.; Spudich, Serena
2008-01-01
Central nervous system (CNS) HIV-1 infection begins during primary viremia and continues throughout the course of untreated systemic infection. While frequently accompanied by local inflammatory reactions detectable in cerebrospinal fluid (CSF), CNS HIV-1 infection is not usually clinically apparent. In a minority of patients, CNS HIV-1 infection evolves late in the course of systemic infection into encephalitis, which compromises brain function and presents clinically as AIDS dementia complex (ADC). Combination highly active antiretroviral therapy (HAART) has had a major impact on all aspects of HIV-1 CNS infection and disease. In those with asymptomatic infection, HAART usually effectively suppresses CSF HIV-1 and markedly reduces the incidence of symptomatic ADC. In those presenting with ADC, HAART characteristically prevents neurological progression and leads to variable, and at times substantial, recovery. Treatment has similarly reduced CNS opportunistic infections. With better control of these severe disorders, attention has turned to the possible consequences of chronic silent infection, and the issue of whether indolent, low-grade brain injury might require earlier treatment intervention. PMID:18447615
NASA Astrophysics Data System (ADS)
Tavousi, Alireza; Mansouri-Birjandi, Mohammad Ali; Saffari, Mehdi
2016-09-01
Implementing of photonic sampling and quantizing analog-to-digital converters (ADCs) enable us to extract a single binary word from optical signals without need for extra electronic assisting parts. This would enormously increase the sampling and quantizing time as well as decreasing the consumed power. To this end, based on the concept of successive approximation method, a 4-bit full-optical ADC that operates using the intensity-dependent Kerr-like nonlinearity in a two dimensional photonic crystal (2DPhC) platform is proposed. The Silicon (Si) nanocrystal is chosen because of the suitable nonlinear material characteristic. An optical limiter is used for the clamping and quantization of each successive levels that represent the ADC bits. In the proposal, an energy efficient optical ADC circuit is implemented by controlling the system parameters such as ring-to-waveguide coupling coefficients, the ring's nonlinear refractive index, and the ring's length. The performance of the ADC structure is verified by the simulation using finite difference time domain (FDTD) method.
2008-12-01
Figure 2. Definition of Attitude Angles and Torque Components in Spacecraft Reference Frame...Figure 5. PD controller in ideal three-axis-stabilized spacecraft ADCS. ................................16 Figure 6. Extract Position Angles function in...performance of spacecraft systems. Two categories of system architectures are discussed: recursive data management, found in feedback control systems; and
Karan, Belgin; Erbay, Gurcan; Koc, Zafer; Pourbagher, Aysin; Yildirim, Sedat; Agildere, Ahmet Muhtesem
2016-11-01
The study sought to evaluate the potential of diffusion-weighted magnetic resonance imaging to detect changes in liver diffusion in benign and malignant distal bile duct obstruction and to investigate the effect of the choice of b-values on apparent diffusion coefficient (ADC). Diffusion-weighted imaging was acquired with b-values of 200, 600, 800, and 1000 s/mm 2 . ADC values were obtained in 4 segments of the liver. The mean ADC values of 16 patients with malignant distal bile duct obstruction, 14 patients with benign distal bile duct obstruction, and a control group of 16 healthy patients were compared. Mean ADC values for 4 liver segments were lower in the malignant obstruction group than in the benign obstruction and control groups using b = 200 s/mm 2 (P < .05). Mean ADC values of the left lobe medial and lateral segments were lower in the malignant obstruction group than in the benign obstructive and control groups using b = 600 s/mm 2 (P < .05). Mean ADC values of the right lobe posterior segment were lower in the malignant and benign obstruction groups than in the control group using b = 1000 s/mm 2 (P < .05). Using b = 800 s/mm 2 , ADC values of all 4 liver segments in each group were not significantly different (P > .05). There were no correlations between the ADC values of liver segments and liver function tests. Measurement of ADC shows good potential for detecting changes in liver diffusion in patients with distal bile duct obstruction. Calculated ADC values were affected by the choice of b-values. Copyright © 2016 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Hong-Bin; Chen, Hu-Cheng; Chen, Kai
ATLAS LAr calorimeter will undergo its Phase-I upgrade during the long shutdown (LS2) in 2018, and a new LAr Trigger Digitizer Board (LTDB) will be designed and installed. Several commercial-off-the-shelf (COTS) multi-channel high-speed ADCs have been selected as possible backups of the radiation tolerant ADC ASICs for the LTDB. Here, to evaluate the radiation tolerance of these backup commercial ADCs, we developed an ADC radiation tolerance characterization system, which includes the ADC boards, data acquisition (DAQ) board, signal generator, external power supplies and a host computer. The ADC board is custom designed for different ADCs, with ADC drivers and clockmore » distribution circuits integrated on board. The Xilinx ZC706 FPGA development board is used as a DAQ board. The data from the ADC are routed to the FPGA through the FMC (FPGA Mezzanine Card) connector, de-serialized and monitored by the FPGA, and then transmitted to the host computer through the Gigabit Ethernet. A software program has been developed with Python, and all the commands are sent to the DAQ board through Gigabit Ethernet by this program. Two ADC boards have been designed for the ADC, ADS52J90 from Texas Instruments and AD9249 from Analog Devices respectively. TID tests for both ADCs have been performed at BNL, and an SEE test for the ADS52J90 has been performed at Massachusetts General Hospital (MGH). Test results have been analyzed and presented. The test results demonstrate that this test system is very versatile, and works well for the radiation tolerance characterization of commercial multi-channel high-speed ADCs for the upgrade of the ATLAS LAr calorimeter. It is applicable to other collider physics experiments where radiation tolerance is required as well.« less
Liu, Hong-Bin; Chen, Hu-Cheng; Chen, Kai; ...
2017-02-01
ATLAS LAr calorimeter will undergo its Phase-I upgrade during the long shutdown (LS2) in 2018, and a new LAr Trigger Digitizer Board (LTDB) will be designed and installed. Several commercial-off-the-shelf (COTS) multi-channel high-speed ADCs have been selected as possible backups of the radiation tolerant ADC ASICs for the LTDB. Here, to evaluate the radiation tolerance of these backup commercial ADCs, we developed an ADC radiation tolerance characterization system, which includes the ADC boards, data acquisition (DAQ) board, signal generator, external power supplies and a host computer. The ADC board is custom designed for different ADCs, with ADC drivers and clockmore » distribution circuits integrated on board. The Xilinx ZC706 FPGA development board is used as a DAQ board. The data from the ADC are routed to the FPGA through the FMC (FPGA Mezzanine Card) connector, de-serialized and monitored by the FPGA, and then transmitted to the host computer through the Gigabit Ethernet. A software program has been developed with Python, and all the commands are sent to the DAQ board through Gigabit Ethernet by this program. Two ADC boards have been designed for the ADC, ADS52J90 from Texas Instruments and AD9249 from Analog Devices respectively. TID tests for both ADCs have been performed at BNL, and an SEE test for the ADS52J90 has been performed at Massachusetts General Hospital (MGH). Test results have been analyzed and presented. The test results demonstrate that this test system is very versatile, and works well for the radiation tolerance characterization of commercial multi-channel high-speed ADCs for the upgrade of the ATLAS LAr calorimeter. It is applicable to other collider physics experiments where radiation tolerance is required as well.« less
NASA Astrophysics Data System (ADS)
Liu, Hong-Bin; Chen, Hu-Cheng; Chen, Kai; Kierstead, James; Lanni, Francesco; Takai, Helio; Jin, Ge
2017-02-01
ATLAS LAr calorimeter will undergo its Phase-I upgrade during the long shutdown (LS2) in 2018, and a new LAr Trigger Digitizer Board (LTDB) will be designed and installed. Several commercial-off-the-shelf (COTS) multi-channel high-speed ADCs have been selected as possible backups of the radiation tolerant ADC ASICs for the LTDB. To evaluate the radiation tolerance of these backup commercial ADCs, we developed an ADC radiation tolerance characterization system, which includes the ADC boards, data acquisition (DAQ) board, signal generator, external power supplies and a host computer. The ADC board is custom designed for different ADCs, with ADC drivers and clock distribution circuits integrated on board. The Xilinx ZC706 FPGA development board is used as a DAQ board. The data from the ADC are routed to the FPGA through the FMC (FPGA Mezzanine Card) connector, de-serialized and monitored by the FPGA, and then transmitted to the host computer through the Gigabit Ethernet. A software program has been developed with Python, and all the commands are sent to the DAQ board through Gigabit Ethernet by this program. Two ADC boards have been designed for the ADC, ADS52J90 from Texas Instruments and AD9249 from Analog Devices respectively. TID tests for both ADCs have been performed at BNL, and an SEE test for the ADS52J90 has been performed at Massachusetts General Hospital (MGH). Test results have been analyzed and presented. The test results demonstrate that this test system is very versatile, and works well for the radiation tolerance characterization of commercial multi-channel high-speed ADCs for the upgrade of the ATLAS LAr calorimeter. It is applicable to other collider physics experiments where radiation tolerance is required as well. Supported by the U. S. Department of Energy (DE-SC001270)
A low-power small-area ADC array for IRFPA readout
NASA Astrophysics Data System (ADS)
Zhong, Shengyou; Yao, Libin
2013-09-01
The readout integrated circuit (ROIC) is a bridge between the infrared focal plane array (IRFPA) and image processing circuit in an infrared imaging system. The ROIC is the first part of signal processing circuit and connected to detectors directly, so its performance will greatly affect the detector or even the whole imaging system performance. With the development of CMOS technologies, it's possible to digitalize the signal inside the ROIC and develop the digital ROIC. Digital ROIC can reduce complexity of the whole system and improve the system reliability. More importantly, it can accommodate variety of digital signal processing techniques which the traditional analog ROIC cannot achieve. The analog to digital converter (ADC) is the most important building block in the digital ROIC. The requirements for ADCs inside the ROIC are low power, high dynamic range and small area. In this paper we propose an RC hybrid Successive Approximation Register (SAR) ADC as the column ADC for digital ROIC. In our proposed ADC structure, a resistor ladder is used to generate several voltages. The proposed RC hybrid structure not only reduces the area of capacitor array but also releases requirement for capacitor array matching. Theory analysis and simulation show RC hybrid SAR ADC is suitable for ADC array applications
CFO compensation method using optical feedback path for coherent optical OFDM system
NASA Astrophysics Data System (ADS)
Moon, Sang-Rok; Hwang, In-Ki; Kang, Hun-Sik; Chang, Sun Hyok; Lee, Seung-Woo; Lee, Joon Ki
2017-07-01
We investigate feasibility of carrier frequency offset (CFO) compensation method using optical feedback path for coherent optical orthogonal frequency division multiplexing (CO-OFDM) system. Recently proposed CFO compensation algorithms provide wide CFO estimation range in electrical domain. However, their practical compensation range is limited by sampling rate of an analog-to-digital converter (ADC). This limitation has not drawn attention, since the ADC sampling rate was high enough comparing to the data bandwidth and CFO in the wireless OFDM system. For CO-OFDM, the limitation is becoming visible because of increased data bandwidth, laser instability (i.e. large CFO) and insufficient ADC sampling rate owing to high cost. To solve the problem and extend practical CFO compensation range, we propose a CFO compensation method having optical feedback path. By adding simple wavelength control for local oscillator, the practical CFO compensation range can be extended to the sampling frequency range. The feasibility of the proposed method is experimentally investigated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Engstroem, K; Casares-Magaz, O; Muren, L
Purpose: Multi-parametric MRI (mp-MRI) is being introduced in radiotherapy (RT) of prostate cancer, including for tumour delineation in focal boosting strategies. We recently developed an image-based tumour control probability model, based on cell density distributions derived from apparent diffusion coefficient (ADC) maps. Beyond tumour volume and cell densities, tumour hypoxia is also an important determinant of RT response. Since tissue perfusion from mp-MRI has been related to hypoxia we have explored the patterns of ADC and perfusion maps, and the relations between them, inside and outside prostate index lesions. Methods: ADC and perfusion maps from 20 prostate cancer patients weremore » used, with the prostate and index lesion delineated by a dedicated uro-radiologist. To reduce noise, the maps were averaged over a 3×3×3 voxel cube. Associations between different ADC and perfusion histogram parameters within the prostate, inside and outside the index lesion, were evaluated with the Pearson’s correlation coefficient. In the voxel-wise analysis, scatter plots of ADC vs perfusion were analysed for voxels in the prostate, inside and outside of the index lesion, again with the associations quantified with the Pearson’s correlation coefficient. Results: Overall ADC was lower inside the index lesion than in the normal prostate as opposed to ktrans that was higher inside the index lesion than outside. In the histogram analysis, the minimum ktrans was significantly correlated with the maximum ADC (Pearson=0.47; p=0.03). At the voxel level, 15 of the 20 cases had a statistically significant inverse correlation between ADC and perfusion inside the index lesion; ten of the cases had a Pearson < −0.4. Conclusion: The minimum value of ktrans across the tumour was correlated to the maximum ADC. However, on the voxel level, the ‘local’ ktrans in the index lesion is inversely (i.e. negatively) correlated to the ‘local’ ADC in most patients. Research agreement with Varian Medical Systems, not related to the work presented in this abstract.« less
Supply chain optimization at an academic medical center.
Labuhn, Jonathan; Almeter, Philip; McLaughlin, Christopher; Fields, Philip; Turner, Benjamin
2017-08-01
A successful supply chain optimization project that leveraged technology, engineering principles, and a technician workflow redesign in the setting of a growing health system is described. With continued rises in medication costs, medication inventory management is increasingly important. Proper management of central pharmacy inventory and floor-stock inventory in automated dispensing cabinets (ADCs) can be challenging. In an effort to improve control of inventory costs in the central pharmacy of a large academic medical center, the pharmacy department implemented a supply chain optimization project in collaboration with the medical center's inhouse team of experts on process improvement and industrial engineering. The project had 2 main components: (1) upgrading and reconfiguring carousel technology within an expanded central pharmacy footprint to generate accurate floor-stock inventory replenishment reports, which resulted in efficiencies within the medication-use system, and (2) implementing a technician workflow redesign and algorithm to right-size the ADC inventory, which decreased inventory stockouts (i.e., incidents of depletion of medication stock) and improved ADC user satisfaction. Through a multifaceted approach to inventory management, the number of stockouts per month was decreased and ADC inventory was optimized, resulting in a one-time inventory cost savings of $220,500. Copyright © 2017 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Song, Ji Soo; Kwak, Hyo Sung; Byon, Jung Hee; Jin, Gong Yong
2017-05-01
To compare the apparent diffusion coefficient (ADC) of upper abdominal organs acquired at different time points, and to investigate the usefulness of normalization. We retrospectively evaluated 58 patients who underwent three rounds of magnetic resonance (MR) imaging including diffusion-weighted imaging of the upper abdomen. MR examinations were performed using three different 3.0 Tesla (T) and one 1.5T systems, with variable b value combinations and respiratory motion compensation techniques. The ADC values of the upper abdominal organs from three different time points were analyzed, using the ADC values of the paraspinal muscle (ADC psm ) and spleen (ADC spleen ) for normalization. Intraclass correlation coefficients (ICC) and comparison of dependent ICCs were used for statistical analysis. The ICCs of the original ADC and ADC psm showed fair to substantial agreement, while ADC spleen showed substantial to almost perfect agreement. The ICC of ADC spleen of all anatomical regions showed less variability compared with that of the original ADC (P < 0.005). Normalized ADC using the spleen as a reference organ significantly decreased variability in measurement of the upper abdominal organs in different MR systems at different time points and could be regarded as an imaging biomarker for future multicenter, longitudinal studies. 5 J. MAGN. RESON. IMAGING 2017;45:1494-1501. © 2016 International Society for Magnetic Resonance in Medicine.
Global analysis of serum microRNAs as potential biomarkers for lung adenocarcinoma.
Rani, Sweta; Gately, Kathy; Crown, John; O'Byrne, Ken; O'Driscoll, Lorraine
2013-12-01
Early diagnosis and the ability to predict the most relevant treatment option for individuals is essential to improve clinical outcomes for non-small cell lung cancer (NSCLC) patients. Adenocarcinoma (ADC), a subtype of NSCLC, is the single biggest cancer killer and therefore an urgent need to identify minimally invasive biomarkers to enable early diagnosis. Recent studies, by ourselves and others, indicate that circulating miRNAs have potential as biomarkers. Here we applied global profiling approaches in serum from patients with ADC of the lung to explore if miRNAs have potential as diagnostic biomarkers. This study involved RNA isolation from 80 sera specimens including those from ADC patients (equal numbers of stages 1, 2, 3, and 4) and age- and gender-matched controls (n = 40 each). Six hundred and sixty-seven miRNAs were co-analyzed in these specimens using TaqMan low density arrays and qPCR validation using individual miRNAs. Overall, approximately 390 and 370 miRNAs were detected in ADC and control sera, respectively. A group of 6 miRNAs, miR-30c-1* (AUC = 0.74; P<0.002), miR-616* (AUC = 0.71; P = 0.001), miR-146b-3p (AUC = 0.82; P<0.0001), miR-566 (AUC = 0.80; P<0.0001), miR-550 (AUC = 0.72; P = 0.0006), and miR-939 (AUC = 0.82; P<0.0001) was found to be present at substantially higher levels in ADC compared with control sera. Conversely, miR-339-5p and miR-656 were detected at substantially lower levels in ADC sera (co-analysis resulting in AUC = 0.6; P = 0.02). Differences in miRNA profile identified support circulating miRNAs having potential as diagnostic biomarkers for ADC. More extensive studies of ADC and control serum specimens are warranted to independently validate the potential clinical relevance of these miRNAs as minimally invasive biomarkers for ADC.
Tokgoz, Ozlem; Unlu, Ebru; Unal, Ilker; Serifoglu, Ismail; Oz, Ilker; Aktas, Elif; Caglar, Emrah
2016-03-01
To investigate the use of diffusion weighted magnetic resonance imaging (DWI) and the apparent diffusion coefficient (ADC) values in the diagnosis of hemangioma. The study population consisted of 72 patients with liver masses larger than 1 cm (72 focal lesions). DWI examination with a b value of 600 s/mm2 was carried out for all patients. After DWI examination, an ADC map was created and ADC values were measured for 72 liver masses and normal liver tissue (control group). The average ADC values of normal liver tissue and focal liver lesions, the "cut-off" ADC values, and the diagnostic sensitivity and specificity of the ADC map in diagnosing hemangioma, benign and malignant lesions were researched. Of the 72 liver masses, 51 were benign and 21 were malignant. Benign lesions comprised 38 hemangiomas and 13 simple cysts. Malignant lesions comprised 9 hepatocellular carcinomas, and 12 metastases. The highest ADC values were measured for cysts (3.782±0.53×10(-3) mm(2)/s) and hemangiomas (2.705±0.63×10(-3) mm(2)/s). The average ADC value of hemangiomas was significantly higher than malignant lesions and the normal control group (p<0.001). The average ADC value of cysts were significantly higher when compared to hemangiomas and normal control group (p<0.001). To distinguish hemangiomas from malignant liver lesions, the "cut-off" ADC value of 1.800×10(-3) mm(2)/s had a sensitivity of 97.4% and a specificity of 90.9%. To distinguish hemangioma from normal liver parenchyma the "cut-off" value of 1.858×10(-3) mm(2)/s had a sensitivity of 97.4% and a specificity of 95.7%. To distinguish benign liver lesions from malignant liver lesions the "cut-off" value of 1.800×10(-3) mm(2)/s had a sensitivity of 96.1% and a specificity of 90.0%. DWI and quantitative measurement of ADC values can be used in differential diagnosis of benign and malignant liver lesions and also in the diagnosis and differentiation of hemangiomas. When dynamic examination cannot distinguish cases with vascular metastasis and lesions from hemangioma, DWI and ADC values can be useful in the primary diagnosis and differential diagnosis. The technique does not require contrast material, so it can safely be used in patients with renal failure.
Arithmetic Data Cube as a Data Intensive Benchmark
NASA Technical Reports Server (NTRS)
Frumkin, Michael A.; Shabano, Leonid
2003-01-01
Data movement across computational grids and across memory hierarchy of individual grid machines is known to be a limiting factor for application involving large data sets. In this paper we introduce the Data Cube Operator on an Arithmetic Data Set which we call Arithmetic Data Cube (ADC). We propose to use the ADC to benchmark grid capabilities to handle large distributed data sets. The ADC stresses all levels of grid memory by producing 2d views of an Arithmetic Data Set of d-tuples described by a small number of parameters. We control data intensity of the ADC by controlling the sizes of the views through choice of the tuple parameters.
Chen, Tai-Yuan; Wu, Te-Chang; Ko, Ching-Chung; Feng, I-Jung; Tsui, Yu-Kun; Lin, Chien-Jen; Chen, Jeon-Hor; Lin, Ching-Po
2017-07-01
Posterior reversible encephalopathy syndrome (PRES) is a clinicoradiologic entity with several causes, characterized by rapid onset of symptoms and typical neuroimaging features, which usually resolve if promptly recognized and treated. Brainstem variant of PRES presents with vasogenic edema in brainstem regions on magnetic resonance (MR) images and there is sparing of the supratentorial regions. Because PRES is usually caused by a hypertensive crisis, which would likely have a systemic effect and global manifestations on the brain tissue, we thus proposed that some microscopic abnormalities of the supratentorial regions could be detected with diffusion-weighted imaging (DWI) using apparent diffusion coefficient (ADC) analysis in brainstem variant of PRES and hypothesized that "normal-looking" supratentorial regions will increase water diffusion. We retrospectively identified patients with PRES who underwent brain magnetic resonance imaging studies. We identified 11 brainstem variants of PRES patients, who formed the study cohort, and 11 typical PRES patients and 20 normal control subjects as the comparison cohorts for this study. Nineteen regions of interest were drawn and systematically placed. The mean ADC values were measured and compared among these 3 groups. ADC values of the typical PRES group were consistently elevated compared with those in normal control subjects. ADC values of the brainstem variant group were consistently elevated compared with those in normal control subjects. ADC values of the typical PRES group and brainstem variant group did not differ significantly, except for the pons area. Quantitative MR DWI may aid in the evaluation of supratentorial microscopic abnormalities in brainstem variant of PRES patients. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Gaur, Sonia; Harmon, Stephanie; Rosenblum, Lauren; Greer, Matthew D; Mehralivand, Sherif; Coskun, Mehmet; Merino, Maria J; Wood, Bradford J; Shih, Joanna H; Pinto, Peter A; Choyke, Peter L; Turkbey, Baris
2018-05-07
The purposes of this study were to assess correlation of apparent diffusion coefficient (ADC) and normalized ADC (ratio of tumor to nontumor tissue) with the Prostate Imaging Reporting and Data System version 2 (PI-RADSv2) and updated International Society of Urological Pathology (ISUP) categories and to determine how to optimally use ADC metrics for objective assistance in categorizing lesions within PI-RADSv2 guidelines. In this retrospective study, 100 patients (median age, 62 years; range, 44-75 years; prostate-specific antigen level, 7.18 ng/mL; range, 1.70-84.56 ng/mL) underwent 3-T multiparametric MRI of the prostate with an endorectal coil. Mean ADC was extracted from ROIs based on subsequent prostatectomy specimens. Histopathologic analysis revealed 172 lesions (113 peripheral, 59 transition zone). Two radiologists blinded to histopathologic outcome assigned PI-RADSv2 categories. Kendall tau was used to correlate ADC metrics with PI-RADSv2 and ISUP categories. ROC curves were used to assess the utility of ADC metrics in differentiating each reader's PI-RADSv2 DWI category 4 or 5 assessment in the whole prostate and by zone. ADC metrics negatively correlated with ISUP category in the whole prostate (ADC, τ = -0.21, p = 0.0002; normalized ADC, τ = -0.21, p = 0.0001). Moderate negative correlation was found in expert PI-RADSv2 DWI categories (ADC, τ = -0.34; normalized ADC, τ = -0.31; each p < 0.0001) maintained across zones. In the whole prostate, AUCs of ADC and normalized ADC were 87% and 82% for predicting expert PI-RADSv2 DWI category 4 or 5. A derived optimal cutoff ADC less than 1061 and normalized ADC less than 0.65 achieved positive predictive values of 83% and 84% for correct classification of PI-RADSv2 DWI category 4 or 5 by an expert reader. Consistent relations and predictive values were found by an independent novice reader. ADC and normalized ADC inversely correlate with PI-RADSv2 and ISUP categories and can serve as quantitative metrics to assist with assigning PI-RADSv2 DWI category 4 or 5.
Length of intact plasma membrane determines the diffusion properties of cellular water.
Eida, Sato; Van Cauteren, Marc; Hotokezaka, Yuka; Katayama, Ikuo; Sasaki, Miho; Obara, Makoto; Okuaki, Tomoyuki; Sumi, Misa; Nakamura, Takashi
2016-01-11
Molecular diffusion in a boundary-free medium depends only on the molecular size, the temperature, and medium viscosity. However, the critical determinant of the molecular diffusion property in inhomogeneous biological tissues has not been identified. Here, using an in vitro system and a high-resolution MR imaging technique, we show that the length of the intact plasma membrane is a major determinant of water diffusion in a controlled cellular environment and that the cell perimeter length (CPL) is sufficient to estimate the apparent diffusion coefficient (ADC) of water in any cellular environment in our experimental system (ADC = -0.21 × CPL + 1.10). We used this finding to further explain the different diffusion kinetics of cells that are dying via apoptotic or non-apoptotic cell death pathways exhibiting characteristic changes in size, nuclear and cytoplasmic architectures, and membrane integrity. These results suggest that the ADC value can be used as a potential biomarker for cell death.
A bunch to bucket phase detector for the RHIC LLRF upgrade platform
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, K.S.; Harvey, M.; Hayes, T.
2011-03-28
As part of the overall development effort for the RHIC LLRF Upgrade Platform [1,2,3], a generic four channel 16 bit Analog-to-Digital Converter (ADC) daughter module was developed to provide high speed, wide dynamic range digitizing and processing of signals from DC to several hundred megahertz. The first operational use of this card was to implement the bunch to bucket phase detector for the RHIC LLRF beam control feedback loops. This paper will describe the design and performance features of this daughter module as a bunch to bucket phase detector, and also provide an overview of its place within the overallmore » LLRF platform architecture as a high performance digitizer and signal processing module suitable to a variety of applications. In modern digital control and signal processing systems, ADCs provide the interface between the analog and digital signal domains. Once digitized, signals are then typically processed using algorithms implemented in field programmable gate array (FPGA) logic, general purpose processors (GPPs), digital signal processors (DSPs) or a combination of these. For the recently developed and commissioned RHIC LLRF Upgrade Platform, we've developed a four channel ADC daughter module based on the Linear Technology LTC2209 16 bit, 160 MSPS ADC and the Xilinx V5FX70T FPGA. The module is designed to be relatively generic in application, and with minimal analog filtering on board, is capable of processing signals from DC to 500 MHz or more. The module's first application was to implement the bunch to bucket phase detector (BTB-PD) for the RHIC LLRF system. The same module also provides DC digitizing of analog processed BPM signals used by the LLRF system for radial feedback.« less
Yılmaz, Sevda; Yumusak, Erhan; Burulday, Veysel
To investigate whether there is any change by measuring ADC values particularly of the optic nerve head (ONH) in patients with diabetic retinopathy (DR). ADC values at the ONHs was measured in 56 patients and 68 controls. ADC values of ONHs were significantly higher in patients with DR compared to controls (p=0.011). ADC values in patients with macular edema were higher than those without macular edema (p=0.017). DWI of ONHs can be useful in cases where it is difficult to assess macular edema during fundus examination, especially in diabetic patients with cataract. Copyright © 2016 Elsevier Inc. All rights reserved.
Epstein, Richard H; Dexter, Franklin; Gratch, David M; Perino, Michael; Magrann, Jerry
2016-06-01
Accurate accounting of controlled drug transactions by inpatient hospital pharmacies is a requirement in the United States under the Controlled Substances Act. At many hospitals, manual distribution of controlled substances from pharmacies is being replaced by automated dispensing cabinets (ADCs) at the point of care. Despite the promise of improved accountability, a high prevalence (15%) of controlled substance discrepancies between ADC records and anesthesia information management systems (AIMS) has been published, with a similar incidence (15.8%; 95% confidence interval [CI], 15.3% to 16.2%) noted at our institution. Most reconciliation errors are clerical. In this study, we describe a method to capture drug transactions in near real-time from our ADCs, compare them with documentation in our AIMS, and evaluate subsequent improvement in reconciliation accuracy. ADC-controlled substance transactions are transmitted to a hospital interface server, parsed, reformatted, and sent to a software script written in Perl. The script extracts the data and writes them to a SQL Server database. Concurrently, controlled drug totals for each patient having care are documented in the AIMS and compared with the balance of the ADC transactions (i.e., vending, transferring, wasting, and returning drug). Every minute, a reconciliation report is available to anesthesia providers over the hospital Intranet from AIMS workstations. The report lists all patients, the current provider, the balance of ADC transactions, the totals from the AIMS, the difference, and whether the case is still ongoing or had concluded. Accuracy and latency of the ADC transaction capture process were assessed via simulation and by comparison with pharmacy database records, maintained by the vendor on a central server located remotely from the hospital network. For assessment of reconciliation accuracy over time, data were collected from our AIMS from January 2012 to June 2013 (Baseline), July 2013 to April 2014 (Next Day Reports), and May 2014 to September 2015 (Near Real-Time Reports) and reconciled against pharmacy records from the central pharmacy database maintained by the vendor. Control chart (batch means) methods were used between successive epochs to determine if improvement had taken place. During simulation, 100% of 10,000 messages, transmitted at a rate of 1295 per minute, were accurately captured and inserted into the database. Latency (transmission time to local database insertion time) was 46.3 ± 0.44 milliseconds (SEM). During acceptance testing, only 1 of 1384 transactions analyzed had a difference between the near real-time process and what was in the central database; this was for a "John Doe" patient whose name had been changed subsequent to data capture. Once a transaction was entered at the ADC workstation, 84.9% (n = 18 bins; 95% CI, 78.4% to 91.3%) of these transactions were available in the database on the AIMS server within 2 minutes. Within 5 minutes, 98.2% (n = 18 bins; 95% CI, 97.2% to 99.3%) were available. Among 145,642 transactions present in the central pharmacy database, only 24 were missing from the local database table (mean = 0.018%; 95% CI, 0.002% to 0.034%). Implementation of near real-time reporting improved the controlled substance reconciliation error rate compared to the previous Next Day Reports epoch, from 8.8% to 5.2% (difference = -3.6%; 95% CI, -4.3% to -2.8%; P < 10). Errors were distributed among staff, with 50% of discrepancies accounted for by 12.4% of providers and 80% accounted for by 28.5% of providers executing transactions during the Near Real-Time Reports epoch. The near real-time system for the capture of transactional data flowing over the hospital network was highly accurate, reliable, and exhibited acceptable latency. This methodology can be used to implement similar data capture for transactions from their drug ADCs. Reconciliation accuracy improved significantly as a result of implementation. Our approach may be of particular utility at facilities with limited pharmacy resources to audit anesthesia records for controlled substance administration and reconcile them against dispensing records.
Diffusion-weighted magnetic resonance imaging of the fetal brain in intrauterine growth restriction.
Arthurs, O J; Rega, A; Guimiot, F; Belarbi, N; Rosenblatt, J; Biran, V; Elmaleh, M; Sebag, G; Alison, M
2017-07-01
Diffusion-weighted magnetic resonance imaging (DWI) is a sensitive method for assessing brain maturation and detecting brain lesions, providing apparent diffusion coefficient (ADC) values as a measure of water diffusion. Abnormal ADC values are seen in ischemic brain lesions, such as those associated with acute or chronic hypoxia. The aim of this study was to assess whether ADC values in the fetal brain were different in fetuses with severe intrauterine growth restriction (IUGR) compared with normal controls. Brain magnetic resonance imaging (MRI) with single-shot axial DWI (b = 0 and b = 700 s/mm 2 ) was performed in 30 fetuses with severe IUGR (estimated fetal weight < 3 rd centile with absent or reversed umbilical artery Doppler flow) and in 24 normal controls of similar gestational age. Brain morphology and biometry were analyzed. ADC values were measured in frontal and occipital white matter, centrum semiovale, thalami, cerebellar hemisphere and pons. Frontal-occipital and frontal-cerebellar ADC ratios were calculated, and values were compared between IUGR fetuses and controls. There was no difference in gestational age at MRI between IUGR and control fetuses (IUGR, 30.2 ± 1.6 weeks vs controls, 30.7 ± 1.4 weeks). Fetal brain morphology and signals were normal in all fetuses. Brain dimensions (supratentorial ± infratentorial) were decreased (Z-score, < -2) in 20 (66.7%) IUGR fetuses. Compared with controls, IUGR fetuses had significantly lower ADC values in frontal white matter (1.97 ± 0.23 vs 2.17 ± 0.22 × 10 -3 mm 2 /s; P < 0.0001), thalami (1.04 ± 0.15 vs 1.13 ± 0.10 ×10 -3 mm 2 /s; P = 0.0002), centrum semiovale (1.86 ± 0.22 vs 1.97 ± 0.23 ×10 -3 mm 2 /s; P = 0.01) and pons (0.85 ± 0.19 vs 0.94 ± 0.12 ×10 -3 mm 2 /s; P = 0.043). IUGR fetuses had a lower frontal-occipital ADC ratio than did normal fetuses (1.00 ± 0.11 vs 1.08 ± 0.05; P = 0.003). ADC values in IUGR fetuses were significantly lower than in normal controls in the frontal white matter, thalami, centrum semiovale and pons, suggesting abnormal maturation in these regions. However, the prognostic value of these ADC changes is still unknown. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
Clauser, Paola; Marcon, Magda; Maieron, Marta; Zuiani, Chiara; Bazzocchi, Massimo; Baltzer, Pascal A T
2016-07-01
To evaluate the influence of post-processing systems, intra- and inter-reader agreement on the variability of apparent diffusion coefficient (ADC) measurements in breast lesions. Forty-one patients with 41 biopsy-proven breast lesions gave their informed consent and were included in this prospective IRB-approved study. Magnetic resonance imaging (MRI) examinations were performed at 1.5 T using an EPI-DWI sequence, with b-values of 0 and 1000 s/mm(2). Two radiologists (R1, R2) reviewed the images in separate sessions and measured the ADC for lesion, using MRI-workstation (S-WS), PACS-workstation (P-WS) and a commercial DICOM viewer (O-SW). Agreement was evaluated using the intraclass correlation coefficient (ICC), Bland-Altman plots and coefficient of variation (CV). Thirty-one malignant, two high-risk and eight benign mass-like lesions were analysed. Intra-reader agreement was almost perfect (ICC-R1 = 0.974; ICC-R2 = 0.990) while inter-reader agreement was substantial (ICC from 0.615 to 0.682). Bland-Altman plots revealed a significant bias in ADC values measured between O-SW and S-WS (P = 0.025), no further systematic differences were identified. CV varied from 6.8 % to 7.9 %. Post-processing systems may have a significant, although minor, impact on ADC measurements in breast lesions. While intra-reader agreement is high, the main source of ADC variability seems to be caused by inter-reader variation. • ADC provides quantitative information on breast lesions independent from the system used. • ADC measurement using different workstations and software systems is generally reliable. • Systematic, but minor, differences may occur between different post-processing systems. • Inter-reader agreement of ADC measurements exceeded intra-reader agreement.
Impact of ADC parameters on linear optical sampling systems
NASA Astrophysics Data System (ADS)
Nguyen, Trung-Hien; Gay, Mathilde; Gomez-Agis, Fausto; Lobo, Sébastien; Sentieys, Olivier; Simon, Jean-Claude; Peucheret, Christophe; Bramerie, Laurent
2017-11-01
Linear optical sampling (LOS), based on the coherent photodetection of an optical signal under test with a low repetition-rate signal originating from a pulsed local oscillator (LO), enables the characterization of the temporal electric field of optical sources. Thanks to this technique, low-speed photodetectors and analog-to-digital converters (ADCs) can be integrated in the LOS system providing a cost-effective tool for characterizing high-speed signals. However, the impact of photodetector and ADC parameters on such LOS systems has not been explored in detail so far. These parameters, including the integration time of the track-and-hold function, the effective number of bits (ENOB) of the ADC, as well as the combined limited bandwidth of the photodetector and ADC are experimentally and numerically investigated in a LOS system for the first time. More specifically, by reconstructing 10-Gbit/s non-return-to-zero on-off keying (NRZ-OOK) and 10-Gbaud NRZ-quadrature phase-shift-keying (QPSK) signals, it is shown that a short integration time provides a better recovered signal fidelity. Furthermore, an ENOB of 6 bits and an ADC bandwidth normalized to the sampling rate of 2.8 are found to be sufficient in order to reliably monitor the considered signals.
ERIC Educational Resources Information Center
Beasley, Conger, Jr.
1993-01-01
Presents different viewpoints concerning the federal government's Animal Damage Control (ADC) Program cited as responsible for killing millions of predators. Critics provide evidence of outdated and inhumane methods exemplified in the coyote killings. The ADC emphasizes new, nonlethal methods of controlling animals cited as "noxious."…
Gray, John P; Ludwig, Brad; Temple, Jack; Melby, Michael; Rough, Steve
2013-08-01
The results of a study to estimate the human resource and cost implications of changing the medication distribution model at a large medical center are presented. A two-part study was conducted to evaluate alternatives to the hospital's existing hybrid distribution model (64% of doses dispensed via cart fill and 36% via automated dispensing cabinets [ADCs]). An assessment of nurse, pharmacist, and pharmacy technician workloads within the hybrid system was performed through direct observation, with time standards calculated for each dispensing task; similar time studies were conducted at a comparator hospital with a decentralized medication distribution system involving greater use of ADCs. The time study data were then used in simulation modeling of alternative distribution scenarios: one involving no use of cart fill, one involving no use of ADCs, and one heavily dependent on ADC dispensing (89% via ADC and 11% via cart fill). Simulation of the base-case and alternative scenarios indicated that as the modeled percentage of doses dispensed from ADCs rose, the calculated pharmacy technician labor requirements decreased, with a proportionately greater increase in the nursing staff workload. Given that nurses are a higher-cost resource than pharmacy technicians, the projected human resource opportunity cost of transitioning from the hybrid system to a decentralized system similar to the comparator facility's was estimated at $229,691 per annum. Based on the simulation results, it was decided that a transition from the existing hybrid medication distribution system to a more ADC-dependent model would result in an unfavorable shift in staff skill mix and corresponding human resource costs at the medical center.
NASA Astrophysics Data System (ADS)
Tavousi, A.; Mansouri-Birjandi, M. A.
2018-02-01
Implementing intensity-dependent Kerr-like nonlinearity in octagonal-shape photonic crystal ring resonators (OSPCRRs), a new class of optical analog-to-digital converters (ADCs) with low power consumption is presented. Due to its size dependent refractive index, Silicon (Si) nanocrystal is used as nonlinear medium in the proposed ADC. Coding system of optical ADC is based on successive-like approximations which requires only one quantization level to represent each single bit, despite of conventional ADCs that require at least two distinct levels for each bit. Each is representing bit of optical ADC is formed by vertically alignment of double rings of OSPCRRs (DR-OSPCRR) and cascading m number of DR-OSPCRR, forms an m bit ADC. Investigating different parameters of DR-OSPCRR such as refractive indices of rings, lattice refractive index, and coupling coefficients of waveguide-to-ring and ring-to-ring, the ADC's threshold power is tuned. Increasing the number of bits of ADC, increases the overall power consumption of ADC. One can arrange to have any number of bits for this ADC, as long as the power levels are treated carefully. Finite difference time domain (FDTD) in-house codes were used to evaluate the ADC's effectiveness.
Kulkarni, Chethana; Finley, James E; Bessire, Andrew J; Zhong, Xiaotian; Musto, Sylvia; Graziani, Edmund I
2017-04-19
As the antibody-drug conjugate (ADC) field grows increasingly important for cancer treatment, it is vital for researchers to establish a firm understanding of how ADCs function at the molecular level. To gain insight into ADC uptake, trafficking, and catabolism-processes that are critical to ADC efficacy and toxicity-imaging studies have been performed with fluorophore-labeled conjugates. However, such labels may alter the properties and behavior of the ADC under investigation. As an alternative approach, we present here the development of a "clickable" ADC bearing an azide-functionalized linker-payload (LP) poised for "click" reaction with alkyne fluorophores; the azide group represents a significantly smaller structural perturbation to the LP than most fluorophores. Notably, the clickable ADC shows excellent potency in target-expressing cells, whereas the fluorophore-labeled product ADC suffers from a significant loss of activity, underscoring the impact of the label itself on the payload. Live-cell confocal microscopy reveals robust uptake of the clickable ADC, which reacts selectively in situ with a derivatized fluorescent label. Time-course trafficking studies show greater and more rapid net internalization of the ADCs than the parent antibody. More generally, the application of chemical biology tools to the study of ADCs should improve our understanding of how ADCs are processed in biological systems.
Microstructural effects of Ramadan fasting on the brain: a diffusion tensor imaging study.
Bakan, Ayse Ahsen; Yıldız, Seyma; Alkan, Alpay; Yetis, Huseyin; Kurtcan, Serpil; Ilhan, Mahmut Muzaffer
2015-01-01
We aimed to examine whether the brain displays any microstructural changes after a three-week Ramadan fasting period using diffusion tenson imaging. This study included a study and a control group of 25 volunteers each. In the study group, we examined and compared apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values of the participants during (phase 1) and after (phase 2) a period of fasting. The control group included individuals who did not fast. ADC and FA values obtained in phase 1 and phase 2 were compared between the study and control groups. In the study group, ADC values of hypothalamus and, to a lesser extent, of insula were lower in phase 1 compared with phase 2 and the control group. The FA values of amygdala, middle temporal cortex, thalamus and, to a lesser extent, of medial prefrontal cortex were lower in phase 1 compared with phase 2 and the control group. Phase 2 ADC and FA values of the study group were not significantly different compared with the control group at any brain location. A three-week Ramadan fasting period can cause microstructural changes in the brain, and diffusion tensor imaging enables the visualization of these changes. The identification of brain locations where changes occurred in ADC and FA values during fasting can be helpful in diagnostic imaging and understanding the pathophysiology of eating disorders.
Microstructural effects of Ramadan fasting on the brain: a diffusion tensor imaging study
Bakan, Ayse Ahsen; Yıldız, Seyma; Alkan, Alpay; Yetis, Huseyin; Kurtcan, Serpil; Ilhan, Mahmut Muzaffer
2015-01-01
PURPOSE We aimed to examine whether the brain displays any microstructural changes after a three-week Ramadan fasting period using diffusion tenson imaging. METHODS This study included a study and a control group of 25 volunteers each. In the study group, we examined and compared apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values of the participants during (phase 1) and after (phase 2) a period of fasting. The control group included individuals who did not fast. ADC and FA values obtained in phase 1 and phase 2 were compared between the study and control groups. RESULTS In the study group, ADC values of hypothalamus and, to a lesser extent, of insula were lower in phase 1 compared with phase 2 and the control group. The FA values of amygdala, middle temporal cortex, thalamus and, to a lesser extent, of medial prefrontal cortex were lower in phase 1 compared with phase 2 and the control group. Phase 2 ADC and FA values of the study group were not significantly different compared with the control group at any brain location. CONCLUSION A three-week Ramadan fasting period can cause microstructural changes in the brain, and diffusion tensor imaging enables the visualization of these changes. The identification of brain locations where changes occurred in ADC and FA values during fasting can be helpful in diagnostic imaging and understanding the pathophysiology of eating disorders. PMID:25835077
Amyloid and tau cerebrospinal fluid biomarkers in HIV infection.
Gisslén, Magnus; Krut, Jan; Andreasson, Ulf; Blennow, Kaj; Cinque, Paola; Brew, Bruce J; Spudich, Serena; Hagberg, Lars; Rosengren, Lars; Price, Richard W; Zetterberg, Henrik
2009-12-22
Because of the emerging intersections of HIV infection and Alzheimer's disease, we examined cerebrospinal fluid (CSF) biomarkers related of amyloid and tau metabolism in HIV-infected patients. In this cross-sectional study we measured soluble amyloid precursor proteins alpha and beta (sAPPalpha and sAPPbeta), amyloid beta fragment 1-42 (Abeta1-42), and total and hyperphosphorylated tau (t-tau and p-tau) in CSF of 86 HIV-infected (HIV+) subjects, including 21 with AIDS dementia complex (ADC), 25 with central nervous system (CNS) opportunistic infections and 40 without neurological symptoms and signs. We also measured these CSF biomarkers in 64 uninfected (HIV-) subjects, including 21 with Alzheimer's disease, and both younger and older controls without neurological disease. CSF sAPPalpha and sAPPbeta concentrations were highly correlated and reduced in patients with ADC and opportunistic infections compared to the other groups. The opportunistic infection group but not the ADC patients had lower CSF Abeta1-42 in comparison to the other HIV+ subjects. CSF t-tau levels were high in some ADC patients, but did not differ significantly from the HIV+ neuroasymptomatic group, while CSF p-tau was not increased in any of the HIV+ groups. Together, CSF amyloid and tau markers segregated the ADC patients from both HIV+ and HIV- neuroasymptomatics and from Alzheimer's disease patients, but not from those with opportunistic infections. Parallel reductions of CSF sAPPalpha and sAPPbeta in ADC and CNS opportunistic infections suggest an effect of CNS immune activation or inflammation on neuronal amyloid synthesis or processing. Elevation of CSF t-tau in some ADC and CNS infection patients without concomitant increase in p-tau indicates neural injury without preferential accumulation of hyperphosphorylated tau as found in Alzheimer's disease. These biomarker changes define pathogenetic pathways to brain injury in ADC that differ from those of Alzheimer's disease.
Photonic ADC: overcoming the bottleneck of electronic jitter.
Khilo, Anatol; Spector, Steven J; Grein, Matthew E; Nejadmalayeri, Amir H; Holzwarth, Charles W; Sander, Michelle Y; Dahlem, Marcus S; Peng, Michael Y; Geis, Michael W; DiLello, Nicole A; Yoon, Jung U; Motamedi, Ali; Orcutt, Jason S; Wang, Jade P; Sorace-Agaskar, Cheryl M; Popović, Miloš A; Sun, Jie; Zhou, Gui-Rong; Byun, Hyunil; Chen, Jian; Hoyt, Judy L; Smith, Henry I; Ram, Rajeev J; Perrott, Michael; Lyszczarz, Theodore M; Ippen, Erich P; Kärtner, Franz X
2012-02-13
Accurate conversion of wideband multi-GHz analog signals into the digital domain has long been a target of analog-to-digital converter (ADC) developers, driven by applications in radar systems, software radio, medical imaging, and communication systems. Aperture jitter has been a major bottleneck on the way towards higher speeds and better accuracy. Photonic ADCs, which perform sampling using ultra-stable optical pulse trains generated by mode-locked lasers, have been investigated for many years as a promising approach to overcome the jitter problem and bring ADC performance to new levels. This work demonstrates that the photonic approach can deliver on its promise by digitizing a 41 GHz signal with 7.0 effective bits using a photonic ADC built from discrete components. This accuracy corresponds to a timing jitter of 15 fs - a 4-5 times improvement over the performance of the best electronic ADCs which exist today. On the way towards an integrated photonic ADC, a silicon photonic chip with core photonic components was fabricated and used to digitize a 10 GHz signal with 3.5 effective bits. In these experiments, two wavelength channels were implemented, providing the overall sampling rate of 2.1 GSa/s. To show that photonic ADCs with larger channel counts are possible, a dual 20-channel silicon filter bank has been demonstrated.
Anderson, Stephan W; Soto, Jorge A; Milch, Holly N; Ozonoff, Al; O'Brien, Michael; Hamilton, James A; Jara, Hernan J
2011-04-01
To evaluate the apparent diffusion coefficient (ADC) values of liver in a murine model of non-alcoholic steatohepatitis using 11.7 Tesla (T) MRI. This animal study was IACUC approved. Seventeen male C57BL/6 mice were divided into control (n = 3) and experimental groups (n = 14) fed a methionine-deficient choline-deficient (MCD) diet to induce steatohepatitis. Livers underwent ex vivo diffusion-weighted MR imaging and ADC maps were calculated. A pathologist determined subjective scores of steatosis, classified from 0 to 3. Digital image analysis was used to determine percentage areas of steatosis. Graphs comparing ADC to subjective and digital image analysis (DIA) determinations of steatosis were plotted. Subjective assessments of steatosis ranged up to values of 3 and DIA determined areas of steatosis to range up to approximately 16%. ADC values approximated 800 × 10(-6) mm(2) /s (range, 749-811 × 10(-6) mm(2) /s, mean 786 × 10(-6) mm(2) /s) in controls and 500 × 10(-6) mm(2) /s (range, 478-733 × 10(-6) mm(2) /s, mean 625 × 10(-6) mm(2) /s) in experimental mice. Moderate correlation between ADC and subjective scores of steatosis (R = -0.56) was observed. Strong correlation between ADC values and percentage areas of steatosis was between ADC values and percentage areas of steatosis was observed greater (R = -0.81) and very strong correlation was observed with the exclusion of a single outlying data point (R = -0.91). Based on the comparison of ADC values and steatosis determinations by DIA, increasing degrees of steatosis are seen to result in decreased hepatic ADC values. Copyright © 2011 Wiley-Liss, Inc.
An 11-bit 200 MS/s subrange SAR ADC with low-cost integrated reference buffer
NASA Astrophysics Data System (ADS)
He, Xiuju; Gu, Xian; Li, Weitao; Jiang, Hanjun; Li, Fule; Wang, Zhihua
2017-10-01
This paper presents an 11-bit 200 MS/s subrange SAR ADC with an integrated reference buffer in 65 nm CMOS. The proposed ADC employs a 3.5-bit flash ADC for coarse conversion, and a compact timing scheme at the flash/SAR boundary to speed up the conversion. The flash decision is used to control charge compensating for the reference voltage to reduce its input-dependent fluctuation. Measurement results show that the fabricated ADC has achieved significant improvement by applying the reference charge compensation. In addition, the ADC achieves a maximum signal-to-noise-and-distortion ratio of 59.3 dB at 200 MS/s. It consumes 3.91 mW from a 1.2 V supply, including the reference buffer. Project supported by the Zhongxing Telecommunication Equipment Corporation and Beijing Microelectronics Technology Institute.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qi, X; Yang, Y; Yang, L
Purpose: To report our initial experience of systematic monitoring treatment response using longitudinal diffusion MR images on a Co-60 MRI-guided radiotherapy system. Methods: Four patients, including 2 head-and-necks, 1 sarcoma and 1 GBM treated on a 0.35 Tesla MRI-guided treatment system, were analyzed. For each patient, 3D TrueFISP MRIs were acquired during CT simulation and before each treatment for treatment planning and patient setup purposes respectively. Additionally, 2D diffusion-weighted MR images (DWI) were acquired weekly throughout the treatment course. The gross target volume (GTV) and brainstem (as a reference structure) were delineated on weekly 3D TrueFISP MRIs to monitor anatomymore » changes, the contours were then transferred onto the corresponding DWI images after fusing with the weekly TrueFISP images. The patient-specific temporal and spatial variations during the entire treatment course, such as anatomic changes, target apparent diffusion coefficient (ADC) distribution were evaluated in a longitudinal pattern. Results: Routine MRI revealed progressive soft-tissue GTV volume changes (up to 53%) for the H&N cases during the treatment course of 5–7 weeks. Within the GTV, the mean ADC values varied from −44% (ADC decrease) to +26% (ADC increase) in a week. The gradual increase of ADC value was inversely associated with target volume variation for one H&N case. The maximal changes of mean ADC values within the brainstem were 5.3% for the H&N cases. For the large size sarcoma and GBM tumors, spatial heterogeneity and temporal variations were observed through longitudinal ADC analysis. Conclusion: In addition to the superior soft-tissue visualization, the 0.35T MR system on ViewRay showed the potential to quantitatively measure the ADC values for both tumor and normal tissues. For normal tissue that is minimally affected by radiation, its ADC values are reproducible. Tumor ADC values show temporal and spatial fluctuation that can be exploited for personalized adaptive therapy.« less
Development of a hardware-in-loop attitude control simulator for a CubeSat satellite
NASA Astrophysics Data System (ADS)
Tapsawat, Wittawat; Sangpet, Teerawat; Kuntanapreeda, Suwat
2018-01-01
Attitude control is an important part in satellite on-orbit operation. It greatly affects the performance of satellites. Testing of an attitude determination and control subsystem (ADCS) is very challenging since it might require attitude dynamics and space environment in the orbit. This paper develops a low-cost hardware-in-loop (HIL) simulator for testing an ADCS of a CubeSat satellite. The simulator consists of a numerical simulation part, a hardware part, and a HIL interface hardware unit. The numerical simulation part includes orbital dynamics, attitude dynamics and Earth’s magnetic field. The hardware part is the real ADCS board of the satellite. The simulation part outputs satellite’s angular velocity and geomagnetic field information to the HIL interface hardware. Then, based on this information, the HIL interface hardware generates I2C signals mimicking the signals of the on-board rate-gyros and magnetometers and consequently outputs the signals to the ADCS board. The ADCS board reads the rate-gyro and magnetometer signals, calculates control signals, and drives the attitude actuators which are three magnetic torquers (MTQs). The responses of the MTQs sensed by a separated magnetometer are feedback to the numerical simulation part completing the HIL simulation loop. Experimental studies are conducted to demonstrate the feasibility and effectiveness of the simulator.
Lung injury induced by secondhand smoke exposure detected with hyperpolarized helium-3 diffusion MR.
Wang, Chengbo; Mugler, John P; de Lange, Eduard E; Patrie, James T; Mata, Jaime F; Altes, Talissa A
2014-01-01
To determine whether helium-3 diffusion MR can detect the changes in the lungs of healthy nonsmoking individuals who were regularly exposed to secondhand smoke. Three groups were studied (age: 59 ± 9 years): 23 smokers, 37 exposure-to-secondhand-smoke subjects, and 29 control subjects. We measured helium-3 diffusion values at diffusion times from 0.23 to 1.97 s. One-way analysis of variance revealed that the mean area under the helium-3 diffusion curves (ADC AUC) of the smokers was significantly elevated compared with the controls and to the exposure-to-secondhand-smoke subjects (P < 0.001 both). No difference between the mean ADC AUC of the exposure-to-secondhand-smoke subjects and that of the controls was found (P = 0.115). However, application of a receiver operator characteristic-derived rule to classify subjects as either a "control" or a "smoker," based on ADC AUC, revealed that 30% (11/37) of the exposure-to-secondhand subjects were classified as "smokers" indicating an elevation of the ADC AUC. Using helium-3 diffusion MR, elevated ADC values were detected in 30% of nonsmoking healthy subjects who had been regularly exposed to secondhand smoke, supporting the concept that, in susceptible individuals, secondhand smoke causes mild lung damage. Copyright © 2013 Wiley Periodicals, Inc.
Application of 23Na MRI to Monitor Chemotherapeutic Response in RIF-1 Tumors1
Babsky, Andriy M; Hekmatyar, Shahryar K; Zhang, Hong; Solomon, James L; Bansal, Navin
2005-01-01
Abstract Effects of an alkylating anticancer drug, cyclophosphamide (Cp), on 23Na signal intensity (23Na SI) and water apparent diffusion coefficient (ADC) were examined in subcutaneously-implanted radiation-induced fibrosarcoma (RIF-1) tumors by in vivo 23Na and 1H magnetic resonance imaging (MRI). MRI experiments were performed on untreated control (n = 5) and Cp-treated (n = 6) C3H mice, once before Cp injection (300 mg/kg) then daily for 3 days after treatment. Tumor volumes were significantly lower in treated animals 2 and 3 days posttreatment. At the same time points, MRI experiments showed an increase in both 23Na SI and water ADC in treated tumors, whereas control tumors did not show any significant changes. The correlation between 23Na SI and water ADC changes was dramatically increased in the Cp-treated group, suggesting that the observed increases in 23Na SI and water ADC were caused by the same mechanism. Histologic sections showed decreased cell density in the regions of increased 23Na and water ADC SI. Destructive chemical analysis showed that Cp treatment increased the relative extracellular space and tumor [Na+]. We conclude that the changes in water ADC and 23Na SI were largely due to an increase in extracellular space. 23Na MRI and 1H water ADC measurements may provide valuable noninvasive techniques for monitoring chemotherapeutic responses. PMID:16026645
2010-01-01
Background Polymorphonuclear neutrophils, stimulated by the activated complement factor C5a, have been implicated in cardiac ischemia/reperfusion injury. ADC-1004 is a competitive C5a receptor antagonist that has been shown to inhibit complement related neutrophil activation. ADC-1004 shields the neutrophils from C5a activation before they enter the reperfused area, which could be a mechanistic advantage compared to previous C5a directed reperfusion therapies. We investigated if treatment with ADC-1004, according to a clinically applicable protocol, would reduce infarct size and microvascular obstruction in a large animal myocardial infarct model. Methods In anesthetized pigs (42-53 kg), a percutaneous coronary intervention balloon was inflated in the left anterior descending artery for 40 minutes, followed by 4 hours of reperfusion. Twenty minutes after balloon inflation the pigs were randomized to an intravenous bolus administration of ADC-1004 (175 mg, n = 8) or saline (9 mg/ml, n = 8). Area at risk (AAR) was evaluated by ex vivo SPECT. Infarct size and microvascular obstruction were evaluated by ex vivo MRI. The observers were blinded to the treatment at randomization and analysis. Results ADC-1004 treatment reduced infarct size by 21% (ADC-1004: 58.3 ± 3.4 vs control: 74.1 ± 2.9%AAR, p = 0.007). Microvascular obstruction was similar between the groups (ADC-1004: 2.2 ± 1.2 vs control: 5.3 ± 2.5%AAR, p = 0.23). The mean plasma concentration of ADC-1004 was 83 ± 8 nM at sacrifice. There were no significant differences between the groups with respect to heart rate, mean arterial pressure, cardiac output and blood-gas data. Conclusions ADC-1004 treatment reduces myocardial ischemia-reperfusion injury and represents a novel treatment strategy of myocardial infarct with potential clinical applicability. PMID:20875134
van der Pals, Jesper; Koul, Sasha; Andersson, Patrik; Götberg, Matthias; Ubachs, Joey F A; Kanski, Mikael; Arheden, Håkan; Olivecrona, Göran K; Larsson, Bengt; Erlinge, David
2010-09-27
Polymorphonuclear neutrophils, stimulated by the activated complement factor C5a, have been implicated in cardiac ischemia/reperfusion injury. ADC-1004 is a competitive C5a receptor antagonist that has been shown to inhibit complement related neutrophil activation. ADC-1004 shields the neutrophils from C5a activation before they enter the reperfused area, which could be a mechanistic advantage compared to previous C5a directed reperfusion therapies. We investigated if treatment with ADC-1004, according to a clinically applicable protocol, would reduce infarct size and microvascular obstruction in a large animal myocardial infarct model. In anesthetized pigs (42-53 kg), a percutaneous coronary intervention balloon was inflated in the left anterior descending artery for 40 minutes, followed by 4 hours of reperfusion. Twenty minutes after balloon inflation the pigs were randomized to an intravenous bolus administration of ADC-1004 (175 mg, n = 8) or saline (9 mg/ml, n = 8). Area at risk (AAR) was evaluated by ex vivo SPECT. Infarct size and microvascular obstruction were evaluated by ex vivo MRI. The observers were blinded to the treatment at randomization and analysis. ADC-1004 treatment reduced infarct size by 21% (ADC-1004: 58.3 ± 3.4 vs control: 74.1 ± 2.9%AAR, p = 0.007). Microvascular obstruction was similar between the groups (ADC-1004: 2.2 ± 1.2 vs control: 5.3 ± 2.5%AAR, p = 0.23). The mean plasma concentration of ADC-1004 was 83 ± 8 nM at sacrifice. There were no significant differences between the groups with respect to heart rate, mean arterial pressure, cardiac output and blood-gas data. ADC-1004 treatment reduces myocardial ischemia-reperfusion injury and represents a novel treatment strategy of myocardial infarct with potential clinical applicability.
Computing shifts to monitor ATLAS distributed computing infrastructure and operations
NASA Astrophysics Data System (ADS)
Adam, C.; Barberis, D.; Crépé-Renaudin, S.; De, K.; Fassi, F.; Stradling, A.; Svatos, M.; Vartapetian, A.; Wolters, H.
2017-10-01
The ATLAS Distributed Computing (ADC) group established a new Computing Run Coordinator (CRC) shift at the start of LHC Run 2 in 2015. The main goal was to rely on a person with a good overview of the ADC activities to ease the ADC experts’ workload. The CRC shifter keeps track of ADC tasks related to their fields of expertise and responsibility. At the same time, the shifter maintains a global view of the day-to-day operations of the ADC system. During Run 1, this task was accomplished by a person of the expert team called the ADC Manager on Duty (AMOD), a position that was removed during the shutdown period due to the reduced number and availability of ADC experts foreseen for Run 2. The CRC position was proposed to cover some of the AMODs former functions, while allowing more people involved in computing to participate. In this way, CRC shifters help with the training of future ADC experts. The CRC shifters coordinate daily ADC shift operations, including tracking open issues, reporting, and representing ADC in relevant meetings. The CRC also facilitates communication between the ADC experts team and the other ADC shifters. These include the Distributed Analysis Support Team (DAST), which is the first point of contact for addressing all distributed analysis questions, and the ATLAS Distributed Computing Shifters (ADCoS), which check and report problems in central services, sites, Tier-0 export, data transfers and production tasks. Finally, the CRC looks at the level of ADC activities on a weekly or monthly timescale to ensure that ADC resources are used efficiently.
Sun, Haitao; Liu, Kai; Liu, Hao; Ji, Zongfei; Yan, Yan; Jiang, Lindi; Zhou, Jianjun
2018-04-01
Background There has been a growing need for a sensitive and effective imaging method for the differentiation of the activity of ankylosing spondylitis (AS). Purpose To compare the performances of intravoxel incoherent motion (IVIM)-derived parameters and the apparent diffusion coefficient (ADC) for distinguishing AS-activity. Material and Methods One hundred patients with AS were divided into active (n = 51) and non-active groups (n = 49) and 21 healthy volunteers were included as control. The ADC, diffusion coefficient ( D), pseudodiffusion coefficient ( D*), and perfusion fraction ( f) were calculated for all groups. Kruskal-Wallis tests and receiver operator characteristic (ROC) curve analysis were performed for all parameters. Results There was good reproducibility of ADC /D and relatively poor reproducibility of D*/f. ADC, D, and f were significantly higher in the active group than in the non-active and control groups (all P < 0.0001, respectively). D* was slightly but significant lower in the active group than in the non-active and control group ( P = 0.0064, 0.0215). There was no significant difference in any parameter between the non-active group and the control group (all P > 0.050). In the ROC analysis, ADC had the largest AUC for distinguishing between the active group and the non-active group (0.988) and between the active and control groups (0.990). Multivariate logistic regression analysis models showed no diagnostic improvement. Conclusion ADC provided better diagnostic performance than IVIM-derived parameters in differentiating AS activity. Therefore, a straightforward and effective mono-exponential model of diffusion-weighted imaging may be sufficient for differentiating AS activity in the clinic.
Zheng, Ping; He, Bin; Guo, Yijun; Zeng, Jingsong; Tong, Wusong
2015-07-01
The relationship between microstructural abnormality in patients with traumatic brain injury (TBI) and hormone-secreting status remains unknown. In this study, the authors aimed to identify the role of the apparent diffusion coefficient (ADC) using a diffusion-weighted imaging (DWI) technique and to evaluate the association of such changes with hypopituitarism in patients with TBI. Diffusion-weighted images were obtained in 164 consecutive patients with TBI within 2 weeks after injury to generate the pituitary ADC as a measure of microstructural change. Patients with TBI were further grouped into those with and those without hypopituitarism based on the secretion status of pituitary hormones at 6 months postinjury. Thirty healthy individuals were enrolled in the study and underwent MRI examinations for comparison. Mean ADC values were compared between this control group, the patients with TBI and hypopituitarism, and the patients with TBI without hypopituitarism; correlational studies were also performed. Neurological outcome was assessed with the Glasgow Outcome Scale (GOS) for all TBI patients 6 months postinjury. In the TBI group, 84 patients had hypopituitarism and 80 had normal pituitary function. The pituitary ADC in TBI patients was significantly less than that in controls (1.83 ± 0.16 vs 4.13 ± 0.33, p < 0.01). Furthermore, the mean ADC was much lower in TBI patients with hypopituitarism than in those without pituitary dysfunction (1.32 ± 0.09 vs 2.28 ± 0.17, p < 0.05). There was also a significant difference in ADC values between patients with hyperprolactinemia and those with normal prolactin levels (p < 0.05). Additionally, the receiver operating characteristic curve analysis showed that the pituitary ADC could predict hypopituitarism with a sensitivity of 90.0% and a specificity of 90.1% at the level of 1.720 (ADC value). Finally, the ADC value was positively correlated with neurological outcome at 6 months following TBI (r = 0.602, p < 0.05). Use of DWI demonstrated that the pituitary ADC is correlated with hormone-secreting status in TBI patients. The authors suggest that pituitary ADC may be a useful biomarker to predict pituitary function in patients with TBI.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Noriega, David C., E-mail: dcnoriega1970@gmail.com; Marcia, Stefano, E-mail: stemarcia@gmail.com; Ardura, Francisco, E-mail: fardura@ono.com
ObjectiveThe purpose of this study was to assess, by the mean apparent diffusion coefficient (ADC), if a relationship exists between disc ADC and MR findings of adjacent disc degeneration after thoracolumbar fractures treated by anatomic reduction using vertebral augmentation (VAP).Materials and MethodsTwenty non-consecutive patients (mean age 50.7 years; range 45–56) treated because of vertebral fractures, were included in this study. There were 10 A3.1 and 10 A1.2 fractures (AO classification). Surgical treatment using VAP was applied in 14 cases, and conservative in 6 patients. MRI T2-weighted images and mapping of apparent diffusion coefficient (ADC) of the intervertebral disc adjacent to themore » fractured segment were performed after a mean follow-up of 32 months. A total of 60 discs, 3 per patient, were analysed: infra-adjacent, supra-adjacent and a control disc one level above the supra-adjacent.ResultsNo differences between patients surgically treated and those following a conservative protocol regarding the average ADC values obtained in the 20 control discs analysed were found. Considering all discs, average ADC in the supra-adjacent level was lower than in the infra-adjacent (1.35 ± 0.12 vs. 1.53 ± 0.06; p < 0.001). Average ADC values of the discs used as a control were similar to those of the infra-adjacent level (1.54 ± 0.06). Compared to surgically treated patients, discs at the supra-adjacent fracture level showed statistically significant lower values in cases treated conservatively (p < 0.001). The variation in the delay of surgery had no influence on the average values of ADC at any of the measured levels.ConclusionsADC measurements of the supra-adjacent discs after a mean follow-up of 32 months following thoracolumbar fractures, showed that restoration of the vertebral collapse by minimally invasive VAP prevents posttraumatic disc degeneration.« less
Abdel Razek, Ahmed Abdel Khalek; El-Said, Amr Abd El-hamid
2017-01-01
Summary Background To assess the role of diffusion-weighted MR imaging in differentiation between Graves’ disease and painless thyroiditis. Material/Methods A prospective study was conducted among 37 consecutive patients with untreated thyrotoxicosis (25 female and 12 male; mean age of 44 years) and 15 ageand sex-matched controls. Diffusion-weighted MR imaging of the thyroid gland was performed in patients and controls. The apparent diffusion coefficient (ADC) value of the thyroid gland was calculated and correlated with Tc-99m uptake and thyroid function tests of the patients. Results There was a significant difference in the ADC value of the thyroid gland between patients and the control group (P=0.001). The mean ADC value of the thyroid gland in Graves’ disease was 2.03±0.28×10–3 mm2/sec, and in patients with painless thyroiditis 1.46±0.22×10–3 mm2/sec, respectively. There was a significant difference in the ADC values between Graves’ disease and painless thyroiditis (P=0.001). When the ADC value of 1.45×10–3 mm2/sec was used as a threshold value for differentiating Graves’ disease from painless thyroiditis, the best result was obtained with area under the curve of 0.934, accuracy of 83.8%, sensitivity of 95.8%, and specificity of 61.5%. The mean ADC value of the thyroid gland in patients positively correlated with serum TRAb and Tc-99m uptake (r=0.57, P=0.001 and r=0.74, P=0.001, respectively). Conclusions We concluded that ADC values of the thyroid gland can be used to differentiate Graves’ disease from painless thyroiditis in patients with untreated thyrotoxicosis. PMID:29662585
Abdel Razek, Ahmed Abdel Khalek; Abd Allah, Sieza Samir; El-Said, Amr Abd El-Hamid
2017-01-01
To assess the role of diffusion-weighted MR imaging in differentiation between Graves' disease and painless thyroiditis. A prospective study was conducted among 37 consecutive patients with untreated thyrotoxicosis (25 female and 12 male; mean age of 44 years) and 15 ageand sex-matched controls. Diffusion-weighted MR imaging of the thyroid gland was performed in patients and controls. The apparent diffusion coefficient (ADC) value of the thyroid gland was calculated and correlated with Tc-99m uptake and thyroid function tests of the patients. There was a significant difference in the ADC value of the thyroid gland between patients and the control group ( P =0.001). The mean ADC value of the thyroid gland in Graves' disease was 2.03±0.28×10 -3 mm 2 /sec, and in patients with painless thyroiditis 1.46±0.22×10 -3 mm 2 /sec, respectively. There was a significant difference in the ADC values between Graves' disease and painless thyroiditis ( P =0.001). When the ADC value of 1.45×10 -3 mm 2 /sec was used as a threshold value for differentiating Graves' disease from painless thyroiditis, the best result was obtained with area under the curve of 0.934, accuracy of 83.8%, sensitivity of 95.8%, and specificity of 61.5%. The mean ADC value of the thyroid gland in patients positively correlated with serum TRAb and Tc-99m uptake ( r =0.57, P =0.001 and r =0.74, P =0.001, respectively). We concluded that ADC values of the thyroid gland can be used to differentiate Graves' disease from painless thyroiditis in patients with untreated thyrotoxicosis.
Avionics of the Cyclone Global Navigation Satellite System (CYGNSS) microsat constellation
NASA Astrophysics Data System (ADS)
Dickinson, John R.; Alvarez, Jennifer L.; Rose, Randall J.; Ruf, Christopher S.; Walls, Buddy J.
The Cyclone Global Navigation Satellite System (CYGNSS), which was recently selected as the Earth Venture-2 investigation by NASA's Earth Science System Pathfinder (ESSP) Program, measures the ocean surface wind field with unprecedented temporal resolution and spatial coverage, under all precipitating conditions, and over the full dynamic range of wind speeds experienced in a tropical cyclone (TC). The CYGNSS flight segment consists of 8 microsatellite-class observatories, which represent SwRI's first spacecraft bus design, installed on a Deployment Module for launch. They are identical in design but provide their own individual contribution to the CYGNSS science data set. Subsystems include the Attitude Determination and Control System (ADCS), the Communication and Data Subsystem (CDS), the Electrical Power Supply (EPS), and the Structure, Mechanisms, and Thermal Subsystem (SMT). This paper will present an overview of the mission and the avionics, including the ADCS, CDS, and EPS, in detail. Specifically, we will detail how off-the-shelf components can be utilized to do ADCS and will highlight how SwRI's existing avionics solutions will be adapted to meet the requirements and cost constraints of microsat applications. Avionics electronics provided by SwRI include a command and data handling computer, a transceiver radio, a low voltage power supply (LVPS), and a peak power tracker (PPT).
Differentiation of Benign and Malignant Head and Neck Lesions With Diffusion Tensor Imaging and DWI.
Koontz, Nicholas A; Wiggins, Richard H
2017-05-01
The purpose of this study was to determine whether diffusion tensor imaging (DTI) can be used to differentiate between benign and malignant head and neck lesions. This retrospective study included patients with head and neck lesions who underwent clinical MRI at 1.5 or 3 T with DWI or DTI parameters. ROI analysis was performed, with lesion-to-medulla apparent diffusion coefficient (ADC) ratios generated. Sixty-five patients with head and neck lesions were included (71 benign, 40 malignant). Twenty-one patients had multiple lesions. Statistically significant differences (p < 0.001) were seen in the mean ADC values ± SD of malignant and benign lesions (0.55 × 10 -3 ± 0.14 × 10 -3 mm 2 /s vs 0.89 × 10 -3 ± 0.29 × 10 -3 mm 2 /s, respectively) and in the mean ADC ratios of malignant and benign lesions (0.88 ± 0.21 vs 1.40 ± 0.44, respectively) with DTI parameters. DTI and DWI parameters produced similar mean ADC ratio values for malignant (0.88 ± 0.21 and 0.92 ± 0.54, respectively) and benign lesions (1.40 ± 0.44 and 1.79 ± 0.52, respectively). ADC ratio thresholds for predicting malignancy for DTI (ADC ratio ≤ 1) and DWI (ADC ratio ≤ 0.94) were also similar. DTI is a useful predictor of malignancy for head and neck lesions, with ADC values of malignant lesions significantly lower than those of benign lesions. DTI ADC values were lower than DWI ADC values for all head and neck lesions in our study group, often below reported malignant DWI threshold values. Normalization of ADC values to an internal control resulted in similar ADC ratios on DWI and DTI.
An, Y Y; Li, H X; Zhan, Y; Lei, X W
2017-10-10
Objective: To evaluate the value of mDIXON-Quant sequence, diffusion-weighted imaging (DWI) in quantitative diagnosing of the sacroiliitis stages in patients with ankylosing spondylitis (AS). Methods: Based on the Bath Ankylosing Spondylitis Activity Index (BASDAI) and laboratory parameters, a total of 51 patients were diagnosed with AS. They were divided into two groups as early active group ( n =20) and chronic active group ( n =31), and at the same time, 25 healthy people from Tianjin were included as control group. The regular MRI sequences and mDIXON-Quant sequence, DWI were obtained. The apparent diffusion coefficient (ADC) and fat-signal fraction (FF) value of bone marrow with edema of the sacroiliac joints in early active group and chronic active group and of subchondral bone marrow of sacroiliac joint in control group all were measured by ADC maps and FF maps. Mean (FF, ADC) values were compared between groups. Results: The ADC value of the early active group, chronic active group and the control group is (1.07±0.20)×10(-3)mm(2)/s, (1.00±0.22)×10(-3)mm(2)/s, (0.25±0.07)×10(-3)mm(2)/s, respectively, and the differences of ADC value between early active group and control group, chronic active group and control group were significant ( P <0.01), but the difference of the ADC value between early active group and chronic active group was not significant ( P =0.394). That is to say, the ADC value can't distinguish the early active group and chronic active group. The differences of FF value between groups was significant ( P <0.01), and the FF value of bone marrow with edema in chronic active group were higher than that in early active group. Conclusions: The mDIXON-Quant sequence can quantitatively diagnose early active group and chronic active group, and the diagnostic value is better than DWI. Thus, it can provide guidance for clinical treatment and prognosis.
Yang, Yingli; Cao, Minsong; Sheng, Ke; Gao, Yu; Chen, Allen; Kamrava, Mitch; Lee, Percy; Agazaryan, Nzhde; Lamb, James; Thomas, David; Low, Daniel; Hu, Peng
2016-03-01
To demonstrate the preliminary feasibility of a longitudinal diffusion magnetic resonance imaging (MRI) strategy for assessing patient response to radiotherapy at 0.35 T using an MRI-guided radiotherapy system (ViewRay). Six patients (three head and neck cancer, three sarcoma) who underwent fractionated radiotherapy were enrolled in this study. A 2D multislice spin echo single-shot echo planar imaging diffusion pulse sequence was implemented on the ViewRay system and tested in phantom studies. The same pulse sequence was used to acquire longitudinal diffusion data (every 2-5 fractions) on the six patients throughout the entire course of radiotherapy. The reproducibility of the apparent diffusion coefficient (ADC) measurements was assessed using reference regions and the temporal variations of the tumor ADC values were evaluated. In diffusion phantom studies, the ADC values measured on the ViewRay system matched well with reference ADC values with <5% error for a range of ground truth diffusion coefficients of 0.4-1.1 × 10(-3) mm(2)/s. The remote reference regions (i.e., brainstem in head and neck patients) had consistent ADC values throughout the therapy for all three head and neck patients, indicating acceptable reproducibility of the diffusion imaging sequence. The tumor ADC values changed throughout therapy, with the change differing between patients, ranging from a 40% drop in ADC within the first week of therapy to gradually increasing throughout therapy. For larger tumors, intratumoral heterogeneity was observed. For one sarcoma patient, postradiotherapy biopsy showed less than 10% necrosis score, which correlated with the observed 40% decrease in ADC from the fifth fraction to the eighth treatment fraction. This pilot study demonstrated that longitudinal diffusion MRI is feasible using the 0.35 T ViewRay MRI. Larger patient cohort studies are warranted to correlate the longitudinal diffusion measurements to patient outcomes. Such an approach may enable response-guided adaptive radiotherapy.
Håberg, Asta Kristine; Skandsen, Toril; Finnanger, Torun Gangaune; Vik, Anne
2014-01-01
Abstract The objective of this study was to explore the evolution of apparent diffusion coefficient (ADC) values in magnetic resonance imaging (MRI) in normal-appearing tissue of the corpus callosum during the 1st year after traumatic brain injury (TBI), and relate findings to outcome. Fifty-seven patients (mean age 34 [range 11–63] years) with moderate to severe TBI were examined with diffusion weighted MRI at three time points (median 7 days, 3 and 12 months), and a sex- and age-matched control group of 47 healthy individuals, were examined once. The corpus callosum was subdivided and the mean ADC values computed blinded in 10 regions of interests without any visible lesions in the ADC map. Outcome measures were Glasgow Outcome Scale Extended (GOSE) and neuropsychological domain scores at 12 months. We found a gradual increase of the mean ADC values during the 12 month follow-up, most evident in the posterior truncus (r=0.19, p<0.001). Compared with the healthy control group, we found higher mean ADC values in posterior truncus both at 3 months (p=0.021) and 12 months (p=0.003) post-injury. Patients with fluid-attenuated inversion recovery (FLAIR) lesions in the corpus callosum in the early MRI, and patients with disability (GOSE score ≤6) showed evidence of increased mean ADC values in the genu and posterior truncus at 12 months. Mean ADC values in posterior parts of the corpus callosum at 3 months predicted the sensory-motor function domain score (p=0.010–0.028). During the 1st year after moderate and severe TBI, we demonstrated a slowly evolving disruption of the microstructure in normal appearing corpus callosum in the ADC map, most evident in the posterior truncus. The mean ADC values were associated with both outcome and ability to perform speeded, complex sensory-motor action. PMID:23837731
Differences in Brain Morphological Findings between Narcolepsy with and without Cataplexy
Nakamura, Masaki; Nishida, Shingo; Hayashida, Kenichi; Ueki, Yoichiro; Dauvilliers, Yves; Inoue, Yuichi
2013-01-01
Objective Maps of fractional anisotropy (FA) and apparent diffusion coefficient (ADC) obtained by diffusion tensor imaging (DTI) can detect microscopic axonal changes by estimating the diffusivity of water molecules using magnetic resonance imaging (MRI). We applied an MRI voxel-based statistical approach to FA and ADC maps to evaluate microstructural abnormalities in the brain in narcolepsy and to investigate differences between patients having narcolepsy with and without cataplexy. Methods Twelve patients with drug-naive narcolepsy with cataplexy (NA/CA), 12 with drug-naive narcolepsy without cataplexy (NA w/o CA) and 12 age-matched healthy normal controls (NC) were enrolled. FA and ADC maps for these 3 groups were statistically compared by using voxel-based one-way ANOVA. In addition, we investigated the correlation between FA and ADC values and clinical variables in the patient groups. Results Compared to the NC group, the NA/CA group showed higher ADC values in the left inferior frontal gyrus and left amygdala, and a lower ADC value in the left postcentral gyrus. The ADC value in the right inferior frontal gyrus and FA value in the right precuneus were higher for NA/CA group than for the NA w/o CA group. However, no significant differences were observed in FA and ADC values between the NA w/o CA and NC groups in any of the areas investigated. In addition, no correlation was found between the clinical variables and ADC and FA values of any brain areas in these patient groups. Conclusions Several microstructural changes were noted in the inferior frontal gyrus and amygdala in the NA/CA but not in the NA w/o CA group. These findings suggest that these 2 narcolepsy conditions have different pathological mechanisms: narcolepsy without cataplexy form appears to be a potentially broader condition without any significant brain imaging differences from normal controls. PMID:24312261
Chen, Tai-Yuan; Wu, Te-Chang; Tsui, Yu-Kun; Chen, Hou-Hsun; Lin, Chien-Jen; Lee, Huey-Jen; Wu, Tai-Ching
2015-01-01
Though diffusion-weighted (DW) magnetic resonance imaging (MRI) is useful for diagnosing many pathologies, its use in infectious spondylodiscitis is unclear. We aimed to evaluate the use of DW MRI and apparent diffusion coefficient (ADC) mapping for the diagnosis of infectious spondylodiscitis. In this retrospective study, 17 patients with confirmed infectious spondylodiscitis were matched by age and level of infected disc with 17 patients with degenerative disc disease (DDD) and 17 healthy controls. All patients received conventional MRI and diffusion-weighted imaging (DWI) in the same imaging session. ADC values of the 3 groups of patients were compared. The mean age of each group was 67.4 ± 11.6 years. The mean ADCs of the normal control, DDD, and infectious spondylodiscitis groups were 1.76 ± 0.19 × 10(-3) , 1.12 ± 0.22 × 10(-3) , and 1.27 ± 0.38 × 10(-3) mm2 /second, respectively. The ADCs of the DDD and infectious spondylodiscitis groups were both significantly lower than that of the normal control group (both, P < 0.001). These data suggest that DWI/ADC MRI may be useful in the early diagnosis of infectious spondylodiscitis. © 2014 The Authors. Journal of Neuroimaging published by Wiley Periodicals, Inc. on behalf of American Society of Neuroimaging.
Zhao, Hui; Gulesserian, Sara; Ganesan, Sathish Kumar; Ou, Jimmy; Morrison, Karen; Zeng, Zhilan; Robles, Veronica; Snyder, Josh; Do, Lisa; Aviña, Hector; Karki, Sher; Stover, David R; Doñate, Fernando
2017-09-01
Thrombocytopenia is a common adverse event in cancer patients treated with antibody-drug conjugates (ADC), including AGS-16C3F, an ADC targeting ENPP3 (ectonucleotide pyrophosphatase/phosphodiesterase-3) and trastuzumab emtansine (T-DM1). This study aims to elucidate the mechanism of action of ADC-induced thrombocytopenia. ENPP3 expression in platelets and megakaryocytes (MK) was investigated and shown to be negative. The direct effect of AGS-16C3F on platelets was evaluated using platelet rich plasma following the expression of platelet activation markers. Effects of AGS-16C3F, T-DM1, and control ADCs on maturing megakaryocytes were evaluated in an in vitro system in which human hematopoietic stem cells (HSC) were differentiated into MKs. AGS-16C3F, like T-DM1, did not affect platelets directly, but inhibited MK differentiation by the activity of Cys-mcMMAF, its active metabolite. FcγRIIA did not appear to play an important role in ADC cytotoxicity to differentiating MKs. AGS-16C3F, cytotoxic to MKs, did not bind to FcγRIIA on MKs. Blocking the interaction of T-DM1 with FcγRIIA did not prevent the inhibition of MK differentiation and IgG1-mcMMAF was not as cytotoxic to MKs despite binding to FcγRIIA. Several lines of evidence suggest that internalization of AGS-16C3F into MKs is mediated by macropinocytosis. Macropinocytosis activity of differentiating HSCs correlated with cell sensitivity to AGS-16C3F. AGS-16C3F was colocalized with a macropinocytosis marker, dextran-Texas Red in differentiating MKs. Ethyl isopropyl amiloride (EIPA), a macropinocytosis inhibitor, blocked internalization of dextran-Texas Red and AGS-16C3F. These data support the notion that inhibition of MK differentiation via macropinocytosis-mediated internalization plays a role in ADC-induced thrombocytopenia. Mol Cancer Ther; 16(9); 1877-86. ©2017 AACR See related article by Zhao et al., p. 1866 . ©2017 American Association for Cancer Research.
Greenwald, Elliot; So, Ernest; Wang, Qihong; Mollazadeh, Mohsen; Maier, Christoph; Etienne-Cummings, Ralph; Cauwenberghs, Gert; Thakor, Nitish
2016-01-01
We present a bidirectional neural interface with a 4-channel biopotential analog-to-digital converter (bioADC) and a 4-channel current-mode stimulator in 180nm CMOS. The bioADC directly transduces microvolt biopotentials into a digital representation without a voltage-amplification stage. Each bioADC channel comprises a continuous-time first-order ΔΣ modulator with a chopper-stabilized OTA input and current feedback, followed by a second-order comb-filter decimator with programmable oversampling ratio. Each stimulator channel contains two independent digital-to-analog converters for anodic and cathodic current generation. A shared calibration circuit matches the amplitude of the anodic and cathodic currents for charge balancing. Powered from a 1.5V supply, the analog and digital circuits in each recording channel draw on average 1.54 μA and 2.13 μA of supply current, respectively. The bioADCs achieve an SNR of 58 dB and a SFDR of >70 dB, for better than 9-b ENOB. Intracranial EEG recordings from an anesthetized rat are shown and compared to simultaneous recordings from a commercial reference system to validate performance in-vivo. Additionally, we demonstrate bidirectional operation by recording cardiac modulation induced through vagus nerve stimulation, and closed-loop control of cardiac rhythm. The micropower operation, direct digital readout, and integration of electrical stimulation circuits make this interface ideally suited for closed-loop neuromodulation applications. PMID:27845676
Rossin, Raffaella; Versteegen, Ron M; Wu, Jeremy; Khasanov, Alisher; Wessels, Hans J; Steenbergen, Erik J; Ten Hoeve, Wolter; Janssen, Henk M; van Onzen, Arthur H A M; Hudson, Peter J; Robillard, Marc S
2018-05-04
Current antibody-drug conjugates (ADCs) target internalising receptors on cancer cells leading to intracellular drug release. Typically, only a subset of patients with solid tumours has sufficient expression of such a receptor, while there are suitable non-internalising receptors and stroma targets. Here, we demonstrate potent therapy in murine tumour models using a non-internalising ADC that releases its drugs upon a click reaction with a chemical activator, which is administered in a second step. This was enabled by the development of a diabody-based ADC with a high tumour uptake and very low retention in healthy tissues, allowing systemic administration of the activator 2 days later, leading to efficient and selective activation throughout the tumour. In contrast, the analogous ADC comprising the protease-cleavable linker used in the FDA approved ADC Adcetris is not effective in these tumour models. This first-in-class ADC holds promise for a broader applicability of ADCs across patient populations.
A 0.9-V 12-bit 40-MSPS Pipeline ADC for Wireless Receivers
NASA Astrophysics Data System (ADS)
Ito, Tomohiko; Itakura, Tetsuro
A 0.9-V 12-bit 40-MSPS pipeline ADC with I/Q amplifier sharing technique is presented for wireless receivers. To achieve high linearity even at 0.9-V supply, the clock signals to sampling switches are boosted over 0.9V in conversion stages. The clock-boosting circuit for lifting these clocks is shared between I-ch ADC and Q-ch ADC, reducing the area penalty. Low supply voltage narrows the available output range of the operational amplifier. A pseudo-differential (PD) amplifier with two-gain-stage common-mode feedback (CMFB) is proposed in views of its wide output range and power efficiency. This ADC is fabricated in 90-nm CMOS technology. At 40MS/s, the measured SNDR is 59.3dB and the corresponding effective number of bits (ENOB) is 9.6. Until Nyquist frequency, the ENOB is kept over 9.3. The ADC dissipates 17.3mW/ch, whose performances are suitable for ADCs for mobile wireless systems such as WLAN/WiMAX.
Botzanowski, Thomas; Erb, Stéphane; Hernandez-Alba, Oscar; Ehkirch, Anthony; Colas, Olivier; Wagner-Rousset, Elsa; Rabuka, David; Beck, Alain; Drake, Penelope M.; Cianférani, Sarah
2017-01-01
ABSTRACT Antibody-drug conjugates (ADCs) have emerged as a family of compounds with promise as efficient immunotherapies. First-generation ADCs were generated mostly via reactions on either lysine side-chain amines or cysteine thiol groups after reduction of the interchain disulfide bonds, resulting in heterogeneous populations with a variable number of drug loads per antibody. To control the position and the number of drug loads, new conjugation strategies aiming at the generation of more homogeneous site-specific conjugates have been developed. We report here the first multi-level characterization of a site-specific ADC by state-of-the-art mass spectrometry (MS) methods, including native MS and its hyphenation to ion mobility (IM-MS). We demonstrate the versatility of native MS methodologies for site-specific ADC analysis, with the unique ability to provide several critical quality attributes within one single run, along with a direct snapshot of ADC homogeneity/heterogeneity without extensive data interpretation. The capabilities of native IM-MS to directly access site-specific ADC conformational information are also highlighted. Finally, the potential of these techniques for assessing an ADC's heterogeneity/homogeneity is illustrated by comparing the analytical characterization of a site-specific DAR4 ADC to that of first-generation ADCs. Altogether, our results highlight the compatibility, versatility, and benefits of native MS approaches for the analytical characterization of all types of ADCs, including site-specific conjugates. Thus, we envision integrating native MS and IM-MS approaches, even in their latest state-of-the-art forms, into workflows that benchmark bioconjugation strategies. PMID:28406343
Durur-Subasi, Irmak; Durur-Karakaya, Afak; Karaman, Adem; Seker, Mehmet; Demirci, Elif; Alper, Fatih
2017-05-01
To determine whether the necrosis/wall apparent diffusion coefficient (ADC) ratio is useful for the malignant-benign differentiation of necrotic breast lesions. Breast MRI was performed using a 3-T system. In this retrospective study, calculation of the necrosis/wall ADC ratio was based on ADC values measured from the necrosis and from the wall of malignant and benign breast lesions by diffusion-weighted imaging (DWI). By synchronizing post-contrast T 1 weighted images, the separate parts of wall and necrosis were maintained. All the diagnoses were pathologically confirmed. Statistical analyses were conducted using an independent sample t-test and receiver operating characteristic analysis. The intraclass and interclass correlations were evaluated. A total of 66 female patients were enrolled, 38 of whom had necrotic breast carcinomas and 28 of whom had breast abscesses. The ADC values were obtained from both the wall and necrosis. The mean necrosis/wall ADC ratio (± standard deviation) was 1.61 ± 0.51 in carcinomas, and it was 0.65 ± 0.33 in abscesses. The area under the curve values for necrosis ADC, wall ADC and the necrosis/wall ADC ratio were 0.680, 0.068 and 0.942, respectively. A wall/necrosis ADC ratio cut-off value of 1.18 demonstrated a sensitivity of 97%, specificity of 93%, a positive-predictive value of 95%, a negative-predictive value of 96% and an accuracy of 95% in determining the malignant nature of necrotic breast lesions. There was a good intra- and interclass reliability for the ADC values of both necrosis and wall. The necrosis/wall ADC ratio appears to be a reliable and promising tool for discriminating breast carcinomas from abscesses using DWI. Advances in knowledge: ADC values of the necrosis obtained by DWI are valuable for malignant-benign differentiation in necrotic breast lesions. The necrosis/wall ADC ratio appears to be a reliable and promising tool in the breast imaging field.
Resolution-Adaptive Hybrid MIMO Architectures for Millimeter Wave Communications
NASA Astrophysics Data System (ADS)
Choi, Jinseok; Evans, Brian L.; Gatherer, Alan
2017-12-01
In this paper, we propose a hybrid analog-digital beamforming architecture with resolution-adaptive ADCs for millimeter wave (mmWave) receivers with large antenna arrays. We adopt array response vectors for the analog combiners and derive ADC bit-allocation (BA) solutions in closed form. The BA solutions reveal that the optimal number of ADC bits is logarithmically proportional to the RF chain's signal-to-noise ratio raised to the 1/3 power. Using the solutions, two proposed BA algorithms minimize the mean square quantization error of received analog signals under a total ADC power constraint. Contributions of this paper include 1) ADC bit-allocation algorithms to improve communication performance of a hybrid MIMO receiver, 2) approximation of the capacity with the BA algorithm as a function of channels, and 3) a worst-case analysis of the ergodic rate of the proposed MIMO receiver that quantifies system tradeoffs and serves as the lower bound. Simulation results demonstrate that the BA algorithms outperform a fixed-ADC approach in both spectral and energy efficiency, and validate the capacity and ergodic rate formula. For a power constraint equivalent to that of fixed 4-bit ADCs, the revised BA algorithm makes the quantization error negligible while achieving 22% better energy efficiency. Having negligible quantization error allows existing state-of-the-art digital beamformers to be readily applied to the proposed system.
Krause, A; Whu, W Z; Qiu, J; Wafadari, D; Hackett, N R; Sharma, A; Crystal, R G; Worgall, S
2013-01-01
Replication-deficient adenoviral (Ad) vectors of non-human serotypes can serve as Ad vaccine platforms to circumvent pre-existing anti-human Ad immunity. We found previously that, in addition to that feature, a non-human primate-based AdC7 vector expressing outer membrane protein F of P. aeruginosa (AdC7OprF) was more potent in inducing lung mucosal and protective immunity compared to a human Ad5-based vector. In this study we analysed if genetic modification of the AdC7 fibre to display an integrin-binding arginine–glycine–aspartic acid (RGD) sequence can further enhance lung mucosal immunogenicity of AdC7OprF. Intratracheal immunization of mice with either AdC7OprF.RGD or AdC7OprF induced robust serum levels of anti-OprF immunoglobulin (Ig)G up to 12 weeks that were higher compared to immunization with the human vectors Ad5OprF or Ad5OprF.RGD. OprF-specific cellular responses in lung T cells isolated from mice immunized with AdC7OprF.RGD and AdC7OprF were similar for T helper type 1 (Th1) [interferon (IFN)-γ in CD8+ and interleukin (IL)-12 in CD4+], Th2 (IL-4, IL-5 and IL-13 in CD4+) and Th17 (IL-17 in CD4+). Interestingly, AdC7OprF.RGD induced more robust protective immunity against pulmonary infection with P. aeruginosa compared to AdC7OprF or the control Ad5 vectors. The enhanced protective immunity induced by AdC7OprF.RGD was maintained in the absence of alveolar macrophages (AM) or CD1d natural killer T cells. Together, the data suggest that addition of RGD to the fibre of an AdC7-based vaccine is useful to enhance its mucosal protective immunogenicity. PMID:23607394
A 10 GS/s time-interleaved ADC in 0.25 micrometer CMOS technology
NASA Astrophysics Data System (ADS)
Aytar, Oktay; Tangel, Ali; Afacan, Engin
2017-11-01
This paper presents design and simulation of a 4-bit 10 GS/s time interleaved ADC in 0.25 micrometer CMOS technology. The designed TI-ADC has 4 channels including 4-bit flash ADC in each channel, in which area and power efficiency are targeted. Therefore, basic standard cell logic gates are preferred. Meanwhile, the aspect ratios in the gate designs are kept as small as possible considering the speed performance. In the literature, design details of the timing control circuits have not been provided, whereas the proposed timing control process is comprehensively explained and design details of the proposed timing control process are clearly presented in this study. The proposed circuits producing consecutive pulses for timing control of the input S/H switches (ie the analog demultiplexer front-end circuitry) and the very fast digital multiplexer unit at the output are the main contributions of this study. The simulation results include +0.26/-0.22 LSB of DNL and +0.01/-0.44 LSB of INL, layout area of 0.27 mm2, and power consumption of 270 mW. The provided power consumption, DNL and INL measures are observed at 100 MHz input with 10 GS/s sampling rate.
Kawada, Y; Yamada, T; Unno, Y; Yunoki, A; Sato, Y; Hino, Y
2012-09-01
A simple but versatile data acquisition system for software coincidence experiments is described, in which any time stamping and live time controller are not provided. Signals from β- and γ-channels are fed to separately two fast ADCs (16 bits, 25 MHz clock maximum) via variable delay circuits and pulse-height stretchers, and also to pulse-height discriminators. The discriminating level was set to just above the electronic noise. Two ADCs were controlled with a common clock signal, and triggered simultaneously by the logic OR pulses from both discriminators. Paired digital signals for each sampling were sent to buffer memories connected to main PC with a FIFO (First-In, First-Out) pipe via USB. After data acquisition in list mode, various processing including pulse-height analyses was performed using MS-Excel (version 2007 and later). The usefulness of this system was demonstrated for 4πβ(PS)-4πγ coincidence measurements of (60)Co, (134)Cs and (152)Eu. Possibilities of other extended applications will be touched upon. Copyright © 2012 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Luna, Michael E.; Collins, Steven M.
2011-01-01
On November 4, 2010 the former "Deep Impact" spacecraft, renamed "EPOXI" for its extended mission, flew within 700km of comet 103P/Hartley 2. In July 2005, the spacecraft had previously imaged a probe impact of comet Tempel 1. The EPOXI flyby was the fifth close encounter of a spacecraft with a comet nucleus and marked the first time in history that two comet nuclei were imaged at close range with the same suite of onboard science instruments. This challenging objective made the function of the attitude determination and control subsystem (ADCS) critical to the successful execution of the EPOXI flyby.As part of the spacecraft flyby preparations, the ADCS operations team had to perform meticulous sequence reviews, implement complex spacecraft engineering and science activities and perform numerous onboard calibrations. ADCS contributions included design and execution of 10 trajectory correction maneuvers, the science calibration of the two telescopic instruments, an in-flight demonstration of high-rate turns between Earth and comet point, and an ongoing assessment of reaction wheel health. The ADCS team was also responsible for command sequences that included updates to the onboard ephemeris and sun sensor coefficients and implementation of reaction wheel assembly (RWA) de-saturations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karki, K; Hugo, G; Ford, J
2014-06-15
Purpose: Diffusion-weighted MRI (DW-MRI) is increasingly being investigated for radiotherapy planning and response assessment. Selection of a limited number of b-values in DW-MRI is important to keep geometrical variations low and imaging time short. We investigated various b-value sets to determine an optimal set for obtaining monoexponential apparent diffusion coefficient (ADC) close to perfusion-insensitive intravoxel incoherent motion (IVIM) model ADC (ADC IVIM) in nonsmall cell lung cancer. Methods: Seven patients had 27 DW-MRI scans before and during radiotherapy in a 1.5T scanner. Respiratory triggering was applied to the echo-planar DW-MRI with TR=4500ms approximately, TE=74ms, pixel size=1.98X1.98mm{sub 2}, slice thickness=4–6mm andmore » 7 axial slices. Diffusion gradients were applied to all three axes producing traceweighted images with eight b-values of 0–1000μs/μm{sup 2}. Monoexponential model ADC values using various b-value sets were compared to ADC IVIM using all b-values. To compare the relative noise in ADC maps, intra-scan coefficient of variation (CV) of active tumor volumes was computed. Results: ADC IVIM, perfusion coefficient and perfusion fraction for tumor volumes were in the range of 880-1622 μm{sup 2}/s, 8119-33834 μm{sup 2}/s and 0.104–0.349, respectively. ADC values using sets of 250, 800 and 1000; 250, 650 and 1000; and 250–1000μs/μm{sup 2} only were not significantly different from ADC IVIM(p>0.05, paired t-test). Error in ADC values for 0–1000, 50–1000, 100–1000, 250–1000, 500–1000, and three b-value sets- 250, 500 and 1000; 250, 650 and 1000; and 250, 800 and 1000μs/μm{sup 2} were 15.0, 9.4, 5.6, 1.4, 11.7, 3.7, 2.0 and 0.2% relative to the reference-standard ADC IVIM, respectively. Mean intrascan CV was 20.2, 20.9, 21.9, 24.9, 32.6, 25.8, 25.4 and 24.8%, respectively, whereas that for ADC IVIM was 23.3%. Conclusion: ADC values of two 3 b-value sets (250, 650 and 1000; and 250, 800 and 1000μs/μm{sup 2}) approached ADC IVIM, with relative noise comparable to that of ADC IVIM. These sets may be used to obtain perfusion-insensitive ADC values in lung tumors. E. Weiss: Funding through Varian Medical Systems and Philips Oncology Systems, UpToDate royalties. G. Hugo: NIH R01CA166119, P01 CA116602, NHMRC Project Grant.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, Y; Yang, Y; Rangwala, N
Purpose: To develop a reliable, 3D distortion-free diffusion MRI technique for longitudinal tumor response assessment and MRI-guided adaptive radiotherapy(RT). Methods: A diffusion prepared 3D turbo spin echo readout (DP-TSE) sequence was developed and compared with the conventional diffusion-weighted single-shot echo-planar-imaging (DW-ssEPI) sequence in a commercially available diffusion phantom, and one head-and-neck and one brain cancer patient on an MRI-guided RT system (ViewRay). In phantom study, the geometric fidelity was quantified as the ratio between the left-right (RL) and anterior-posterior (AP) dimension. Ten slices were measured on DP-TSE, DW-ssEPI and standard TSE images where the later was used as the geometricmore » reference. ADC accuracy was verified at both 0°C (reference ADC available) and room temperature with a range of diffusivity between 0.35 and 2.0*10{sup −3}mm{sup 2}/s. The ADC reproducibility was assessed based on 8 room-temperature measurements on 6 different days. In the pilot single-slice in-vivo study, CT images were used as the geometric reference, and ADC maps from both diffusion sequences were compared. Results: Distortion and susceptive-related artifact were severe in DW-ssEPI, with significantly lower RL/AP ratio (0.9579±0.0163) than DP-TSE (0.9990±0.0031) and TSE (0.9995±0.0031). ADCs from the two diffusion sequences both matched well with the vendor-provided values at 0°C; however DW-ssEPI fails to provide accurate ADC for high diffusivity vials at room temperature due to high noise level (10 times higher than DP-TSE). The DP-TSE sequence had excellent ADC reproducibility with <4% ADC variation among 8 separate measurements. In patient study, DP-TSE exhibited substantially improved geometric reliability. ROI analysis in ADC maps generated from DP-TSE and DW-ssEPI showed <5% difference where high b-value images were excluded from the latter approach due to excessive noise level. Conclusion: A diffusion MRI sequence with excellent geometric fidelity, accurate and highly reproducible ADC measurements was proposed for longitudinal tumor response assessment using an MRI-guided RT system. Yu Gao acknowledges research support from ViewRay.« less
Hess, C P; Christine, C W; Apple, A C; Dillon, W P; Aminoff, M J
2014-05-01
The thalamus is interconnected with the nigrostriatal system and cerebral cortex and has a major role in cognitive function and sensorimotor integration. The purpose of this study was to determine how regional involvement of the thalamus differs among Parkinson disease, progressive supranuclear palsy, and corticobasal syndrome. Nine patients with Parkinson disease, 5 with progressive supranuclear palsy, and 6 with corticobasal syndrome underwent 3T MR imaging along with 12 matched, asymptomatic volunteers by using a protocol that included volumetric T1 and diffusion tensor imaging. Acquired data were automatically processed to delineate the margins of the motor and nonmotor thalamic nuclear groups, and measurements of ADC were calculated from the DTI data within these regions. Thalamic volume, shape, and ADC were compared across groups. Thalamic volume was smaller in the progressive supranuclear palsy and corticobasal syndrome groups compared with the Parkinson disease and control groups. Shape analysis revealed that this was mainly due to the diminished size of the lateral thalamus. Overall, ADC measurements were higher in the progressive supranuclear palsy group compared with both the Parkinson disease and control groups, and anatomic subgroup analysis demonstrated that these changes were greater within the motor regions of the thalamus in progressive supranuclear palsy and corticobasal degeneration. Reduced size and increased ADC disproportionately involve the lateral thalamus in progressive supranuclear palsy and corticobasal syndrome, consistent with selective neurodegeneration and atrophy in this region. Because these findings were not observed in Parkinson disease, they may be more specific markers of tau-related neurodegeneration. © 2014 by American Journal of Neuroradiology.
An ultra low-power front-end IC for wearable health monitoring system.
Yu-Pin Hsu; Zemin Liu; Hella, Mona M
2016-08-01
This paper presents a low-power front-end IC for wearable health monitoring systems. The IC, designed in a standard 0.13μm CMOS technology, fully integrates a low-noise analog front-end (AFE) to process the weak bio-signals, followed by an analog-to-digital converter (ADC) to digitize the extracted signals. An AC-coupled driving buffer, that interfaces between the AFE and the ADC is introduced to scale down the power supply of the ADC. The power consumption decreases by 50% compared to the case without power supply scaling. The AFE passes signals from 0.5Hz to 280Hz and from 0.7Hz to 160Hz with a simulated input referred noise of 1.6μVrms and achieves a maximum gain of 35dB/41dB respectively, with a noise-efficiency factor (NEF) of the AFE is 1. The 8-bit ADC achieves a simulated 7.96-bit resolution at 10KS/s sampling rate under 0.5V supply voltage. The overall system consumes only 0.86μW at dual supply voltages of 1V (AFE) and 0.5 V (ADC).
New data acquisition system for beam loss monitor used in J-PARC main ring
NASA Astrophysics Data System (ADS)
Satou, K.; Toyama, T.; Kamikubota, N.; Yoshida, S.; Matsushita, J.; Wakita, T.; Sugiyama, M.; Morino, T.
2018-04-01
A new data acquisition system has been developed continually as a part of the development of a new beam loss monitor (BLM) system for the J-PARC main ring. This development includes a newly designed front-end isolation amp that uses photo-couplers and a VME-based new analog-to-digital converter (ADC) system. Compared to the old amp, the new amp has a 10 times higher conversion impedance for the input current to the output voltage; this value is 1 M Ω. Moreover, the bandwidth was improved to from DC to 50 kHz, which is about two orders of magnitude greater than the previously used bandwidth. The theoretical estimations made in this study roughly agree with the frequency response obtained for the new system. The new ADC system uses an on-board field-programmable gate array chip for signal processing. By replacing the firmware of this chip, changes pertaining to future accelerator upgrade plans may be introduced into the new ADC system; in addition, the ADC system can be used in other applications. The sampling speed of the system is 1 MS/s, and it exhibits a 95 dBc spurious-free dynamic range and 16.5 effective number of bits. The obtained waveform and integrated charge data are compared with two reference levels in the ADC system. If the data exceeds the reference level, the system generates an alarm to dump the beams. By using the new data acquisition system, it was proved that the new BLM system shows a wide dynamic range of 160 dB. In this study, the details of the new data acquisition system are described.
2014-08-04
Resident Space Object Proximity Analysis and IMAging) mission is carried out by a 6U Cube Sat class satellite equipped with a warm gas propulsion system... mission . The ARAPAIMA (Application for Resident Space Object Proximity Analysis and IMAging) mission is carried out by a 6 U CubeSat class satellite...attitude determination and control subsystem (ADCS) (or a proximity operation and imaging satellite mission . The ARAP AI MA (Application for
Schob, Stefan; Meyer, Hans Jonas; Dieckow, Julia; Pervinder, Bhogal; Pazaitis, Nikolaos; Höhn, Anne Kathrin; Garnov, Nikita; Horvath-Rizea, Diana; Hoffmann, Karl-Titus; Surov, Alexey
2017-04-12
Pre-surgical diffusion weighted imaging (DWI) is increasingly important in the context of thyroid cancer for identification of the optimal treatment strategy. It has exemplarily been shown that DWI at 3T can distinguish undifferentiated from well-differentiated thyroid carcinoma, which has decisive implications for the magnitude of surgery. This study used DWI histogram analysis of whole tumor apparent diffusion coefficient (ADC) maps. The primary aim was to discriminate thyroid carcinomas which had already gained the capacity to metastasize lymphatically from those not yet being able to spread via the lymphatic system. The secondary aim was to reflect prognostically important tumor-biological features like cellularity and proliferative activity with ADC histogram analysis. Fifteen patients with follicular-cell derived thyroid cancer were enrolled. Lymph node status, extent of infiltration of surrounding tissue, and Ki-67 and p53 expression were assessed in these patients. DWI was obtained in a 3T system using b values of 0, 400, and 800 s/mm². Whole tumor ADC volumes were analyzed using a histogram-based approach. Several ADC parameters showed significant correlations with immunohistopathological parameters. Most importantly, ADC histogram skewness and ADC histogram kurtosis were able to differentiate between nodal negative and nodal positive thyroid carcinoma. histogram analysis of whole ADC tumor volumes has the potential to provide valuable information on tumor biology in thyroid carcinoma. However, further studies are warranted.
Schob, Stefan; Meyer, Hans Jonas; Dieckow, Julia; Pervinder, Bhogal; Pazaitis, Nikolaos; Höhn, Anne Kathrin; Garnov, Nikita; Horvath-Rizea, Diana; Hoffmann, Karl-Titus; Surov, Alexey
2017-01-01
Pre-surgical diffusion weighted imaging (DWI) is increasingly important in the context of thyroid cancer for identification of the optimal treatment strategy. It has exemplarily been shown that DWI at 3T can distinguish undifferentiated from well-differentiated thyroid carcinoma, which has decisive implications for the magnitude of surgery. This study used DWI histogram analysis of whole tumor apparent diffusion coefficient (ADC) maps. The primary aim was to discriminate thyroid carcinomas which had already gained the capacity to metastasize lymphatically from those not yet being able to spread via the lymphatic system. The secondary aim was to reflect prognostically important tumor-biological features like cellularity and proliferative activity with ADC histogram analysis. Fifteen patients with follicular-cell derived thyroid cancer were enrolled. Lymph node status, extent of infiltration of surrounding tissue, and Ki-67 and p53 expression were assessed in these patients. DWI was obtained in a 3T system using b values of 0, 400, and 800 s/mm2. Whole tumor ADC volumes were analyzed using a histogram-based approach. Several ADC parameters showed significant correlations with immunohistopathological parameters. Most importantly, ADC histogram skewness and ADC histogram kurtosis were able to differentiate between nodal negative and nodal positive thyroid carcinoma. Conclusions: histogram analysis of whole ADC tumor volumes has the potential to provide valuable information on tumor biology in thyroid carcinoma. However, further studies are warranted. PMID:28417929
Singh, Aman P; Maass, Katie F; Betts, Alison M; Wittrup, K Dane; Kulkarni, Chethana; King, Lindsay E; Khot, Antari; Shah, Dhaval K
2016-07-01
A mathematical model capable of accurately characterizing intracellular disposition of ADCs is essential for a priori predicting unconjugated drug concentrations inside the tumor. Towards this goal, the objectives of this manuscript were to: (1) evolve previously published cellular disposition model of ADC with more intracellular details to characterize the disposition of T-DM1 in different HER2 expressing cell lines, (2) integrate the improved cellular model with the ADC tumor disposition model to a priori predict DM1 concentrations in a preclinical tumor model, and (3) identify prominent pathways and sensitive parameters associated with intracellular activation of ADCs. The cellular disposition model was augmented by incorporating intracellular ADC degradation and passive diffusion of unconjugated drug across tumor cells. Different biomeasures and chemomeasures for T-DM1, quantified in the companion manuscript, were incorporated into the modified model of ADC to characterize in vitro pharmacokinetics of T-DM1 in three HER2+ cell lines. When the cellular model was integrated with the tumor disposition model, the model was able to a priori predict tumor DM1 concentrations in xenograft mice. Pathway analysis suggested different contribution of antigen-mediated and passive diffusion pathways for intracellular unconjugated drug exposure between in vitro and in vivo systems. Global and local sensitivity analyses revealed that non-specific deconjugation and passive diffusion of the drug across tumor cell membrane are key parameters for drug exposure inside a cell. Finally, a systems pharmacokinetic model for intracellular processing of ADCs has been proposed to highlight our current understanding about the determinants of ADC activation inside a cell.
Babsky, Andriy M; Hekmatyar, S K; Zhang, Hong; Solomon, James L; Bansal, Navin
2006-07-01
To examine the effects of the alkylating anticancer drug 1,3-bis(2-chloroethyl)-1-nitrosourea (BCNU) on (23)Na MRI and the water apparent diffusion coefficient (ADC) in subcutaneously- (sc-) implanted 9L glioma in rats. (23)Na MRI and (1)H water ADC measurements were performed on sham-treated control (N = 6) and BCNU-treated (N = 15) Fisher rats one day before BCNU injection and then one, three, and five days after BCNU injection. The BCNU-treated tumors were divided into BCNU-responsive (R(BCNU)) and BCNU-nonresponsive (NR(BCNU)) groups depending on the tumor volume changes that occurred after therapy. The pretreatment (23)Na MRI signal intensity (SI) and water ADC values were higher in R(BCNU) tumors compared to NR(BCNU) tumors. (23)Na MRI SI and water ADC increased with tumor growth in control and NR(BCNU) groups, but these changes were interrupted by BCNU therapy in R(BCNU) group. (23)Na MRI and water ADC measurements may be useful for predicting and monitoring response to chemotherapy in some tumors. However, the changes that occurred in (23)Na MRI SI and water ADC in sc-implanted 9L tumors are in contrast to previously published results for BCNU therapy of orthotopic 9L tumors. This may have important implications for monitoring therapy response in tumors. (c) 2006 Wiley-Liss, Inc.
Durur-Karakaya, Afak; Karaman, Adem; Seker, Mehmet; Demirci, Elif; Alper, Fatih
2017-01-01
Objective: To determine whether the necrosis/wall apparent diffusion coefficient (ADC) ratio is useful for the malignant–benign differentiation of necrotic breast lesions. Methods: Breast MRI was performed using a 3-T system. In this retrospective study, calculation of the necrosis/wall ADC ratio was based on ADC values measured from the necrosis and from the wall of malignant and benign breast lesions by diffusion-weighted imaging (DWI). By synchronizing post-contrast T1 weighted images, the separate parts of wall and necrosis were maintained. All the diagnoses were pathologically confirmed. Statistical analyses were conducted using an independent sample t-test and receiver operating characteristic analysis. The intraclass and interclass correlations were evaluated. Results: A total of 66 female patients were enrolled, 38 of whom had necrotic breast carcinomas and 28 of whom had breast abscesses. The ADC values were obtained from both the wall and necrosis. The mean necrosis/wall ADC ratio (± standard deviation) was 1.61 ± 0.51 in carcinomas, and it was 0.65 ± 0.33 in abscesses. The area under the curve values for necrosis ADC, wall ADC and the necrosis/wall ADC ratio were 0.680, 0.068 and 0.942, respectively. A wall/necrosis ADC ratio cut-off value of 1.18 demonstrated a sensitivity of 97%, specificity of 93%, a positive-predictive value of 95%, a negative-predictive value of 96% and an accuracy of 95% in determining the malignant nature of necrotic breast lesions. There was a good intra- and interclass reliability for the ADC values of both necrosis and wall. Conclusion: The necrosis/wall ADC ratio appears to be a reliable and promising tool for discriminating breast carcinomas from abscesses using DWI. Advances in knowledge: ADC values of the necrosis obtained by DWI are valuable for malignant-benign differentiation in necrotic breast lesions. The necrosis/wall ADC ratio appears to be a reliable and promising tool in the breast imaging field. PMID:28339285
A two-step A/D conversion and column self-calibration technique for low noise CMOS image sensors.
Bae, Jaeyoung; Kim, Daeyun; Ham, Seokheon; Chae, Youngcheol; Song, Minkyu
2014-07-04
In this paper, a 120 frames per second (fps) low noise CMOS Image Sensor (CIS) based on a Two-Step Single Slope ADC (TS SS ADC) and column self-calibration technique is proposed. The TS SS ADC is suitable for high speed video systems because its conversion speed is much faster (by more than 10 times) than that of the Single Slope ADC (SS ADC). However, there exist some mismatching errors between the coarse block and the fine block due to the 2-step operation of the TS SS ADC. In general, this makes it difficult to implement the TS SS ADC beyond a 10-bit resolution. In order to improve such errors, a new 4-input comparator is discussed and a high resolution TS SS ADC is proposed. Further, a feedback circuit that enables column self-calibration to reduce the Fixed Pattern Noise (FPN) is also described. The proposed chip has been fabricated with 0.13 μm Samsung CIS technology and the chip satisfies the VGA resolution. The pixel is based on the 4-TR Active Pixel Sensor (APS). The high frame rate of 120 fps is achieved at the VGA resolution. The measured FPN is 0.38 LSB, and measured dynamic range is about 64.6 dB.
Oldland, Alan R.; May, Sondra K.; Barber, Gerard R.; Stolpman, Nancy M.
2015-01-01
Purpose: To measure the effects associated with sequential implementation of electronic medication storage and inventory systems and product verification devices on pharmacy technical accuracy and rates of potential medication dispensing errors in an academic medical center. Methods: During four 28-day periods of observation, pharmacists recorded all technical errors identified at the final visual check of pharmaceuticals prior to dispensing. Technical filling errors involving deviations from order-specific selection of product, dosage form, strength, or quantity were documented when dispensing medications using (a) a conventional unit dose (UD) drug distribution system, (b) an electronic storage and inventory system utilizing automated dispensing cabinets (ADCs) within the pharmacy, (c) ADCs combined with barcode (BC) verification, and (d) ADCs and BC verification utilized with changes in product labeling and individualized personnel training in systems application. Results: Using a conventional UD system, the overall incidence of technical error was 0.157% (24/15,271). Following implementation of ADCs, the comparative overall incidence of technical error was 0.135% (10/7,379; P = .841). Following implementation of BC scanning, the comparative overall incidence of technical error was 0.137% (27/19,708; P = .729). Subsequent changes in product labeling and intensified staff training in the use of BC systems was associated with a decrease in the rate of technical error to 0.050% (13/26,200; P = .002). Conclusions: Pharmacy ADCs and BC systems provide complementary effects that improve technical accuracy and reduce the incidence of potential medication dispensing errors if this technology is used with comprehensive personnel training. PMID:25684799
Oldland, Alan R; Golightly, Larry K; May, Sondra K; Barber, Gerard R; Stolpman, Nancy M
2015-01-01
To measure the effects associated with sequential implementation of electronic medication storage and inventory systems and product verification devices on pharmacy technical accuracy and rates of potential medication dispensing errors in an academic medical center. During four 28-day periods of observation, pharmacists recorded all technical errors identified at the final visual check of pharmaceuticals prior to dispensing. Technical filling errors involving deviations from order-specific selection of product, dosage form, strength, or quantity were documented when dispensing medications using (a) a conventional unit dose (UD) drug distribution system, (b) an electronic storage and inventory system utilizing automated dispensing cabinets (ADCs) within the pharmacy, (c) ADCs combined with barcode (BC) verification, and (d) ADCs and BC verification utilized with changes in product labeling and individualized personnel training in systems application. Using a conventional UD system, the overall incidence of technical error was 0.157% (24/15,271). Following implementation of ADCs, the comparative overall incidence of technical error was 0.135% (10/7,379; P = .841). Following implementation of BC scanning, the comparative overall incidence of technical error was 0.137% (27/19,708; P = .729). Subsequent changes in product labeling and intensified staff training in the use of BC systems was associated with a decrease in the rate of technical error to 0.050% (13/26,200; P = .002). Pharmacy ADCs and BC systems provide complementary effects that improve technical accuracy and reduce the incidence of potential medication dispensing errors if this technology is used with comprehensive personnel training.
Thomson Scattering Diagnostic Data Acquisition Systems for Modern Fusion Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ivanenko, S.V.; Khilchenko, A.D.; Ovchar, V.K.
2015-07-01
Uniquely designed complex data acquisition system for Thomson scattering diagnostic was developed. It allows recording short duration (3-5 ns) scattered pulses with 2 GHz sampling rate and 10-bit total resolution in oscilloscope mode. The system consists up to 48 photo detector modules with 0- 200 MHz bandwidth, 1-48 simultaneously sampling ADC modules and synchronization subsystem. The photo detector modules are based on avalanche photodiodes (APD) and ultra-low noise trans-impedance amplifiers. ADC modules include fast analog to digital converters and digital units based on the FPGA (Field- Programmable Gate Array) for data processing and storage. The synchronization subsystem is used tomore » form triggering pulses and to organize the simultaneously mode of ADC modules operation. (authors)« less
Self-Calibration Approach for Mixed Signal Circuits in Systems-on-Chip
NASA Astrophysics Data System (ADS)
Jung, In-Seok
MOSFET scaling has served industry very well for a few decades by proving improvements in transistor performance, power, and cost. However, they require high test complexity and cost due to several issues such as limited pin count and integration of analog and digital mixed circuits. Therefore, self-calibration is an excellent and promising method to improve yield and to reduce manufacturing cost by simplifying the test complexity, because it is possible to address the process variation effects by means of self-calibration technique. Since the prior published calibration techniques were developed for a specific targeted application, it is not easy to be utilized for other applications. In order to solve the aforementioned issues, in this dissertation, several novel self-calibration design techniques in mixed-signal mode circuits are proposed for an analog to digital converter (ADC) to reduce mismatch error and improve performance. These are essential components in SOCs and the proposed self-calibration approach also compensates the process variations. The proposed novel self-calibration approach targets the successive approximation (SA) ADC. First of all, the offset error of the comparator in the SA-ADC is reduced using the proposed approach by enabling the capacitor array in the input nodes for better matching. In addition, the auxiliary capacitors for each capacitor of DAC in the SA-ADC are controlled by using synthesized digital controller to minimize the mismatch error of the DAC. Since the proposed technique is applied during foreground operation, the power overhead in SA-ADC case is minimal because the calibration circuit is deactivated during normal operation time. Another benefit of the proposed technique is that the offset voltage of the comparator is continuously adjusted for every step to decide one-bit code, because not only the inherit offset voltage of the comparator but also the mismatch of DAC are compensated simultaneously. Synthesized digital calibration control circuit operates as fore-ground mode, and the controller has been highly optimized for low power and better performance with simplified structure. In addition, in order to increase the sampling clock frequency of proposed self-calibration approach, novel variable clock period method is proposed. To achieve high speed SAR operation, a variable clock time technique is used to reduce not only peak current but also die area. The technique removes conversion time waste and extends the SAR operation speed easily. To verify and demonstrate the proposed techniques, a prototype charge-redistribution SA-ADCs with the proposed self-calibration is implemented in a 130nm standard CMOS process. The prototype circuit's silicon area is 0.0715 mm 2 and consumers 4.62mW with 1.2V power supply.
Sauter, Alexander W; Stieltjes, Bram; Weikert, Thomas; Gatidis, Sergios; Wiese, Mark; Klarhöfer, Markus; Wild, Damian; Lardinois, Didier; Bremerich, Jens; Sommer, Gregor
2017-01-01
The minimum apparent diffusion coefficient (ADC min ) derived from diffusion-weighted MRI (DW-MRI) and the maximum standardized uptake value (SUV max ) of FDG-PET are markers of aggressiveness in lung cancer. The numeric correlation of the two parameters has been extensively studied, but their spatial interplay is not well understood. After FDG-PET and DW-MRI coregistration, values and location of ADC min - and SUV max -voxels were analyzed. The upper limit of the 95% confidence interval for registration accuracy of sequential PET/MRI was 12 mm, and the mean distance ( D ) between ADC min - and SUV max -voxels was 14.0 mm (average of two readers). Spatial mismatch ( D > 12 mm) between ADC min and SUV max was found in 9/25 patients. A considerable number of mismatch cases (65%) was also seen in a control group that underwent simultaneous PET/MRI. In the entire patient cohort, no statistically significant correlation between SUV max and ADC min was seen, while a moderate negative linear relationship ( r = -0.5) between SUV max and ADC min was observed in tumors with a spatial match ( D ≤ 12 mm). In conclusion, spatial mismatch between ADC min and SUV max is found in a considerable percentage of patients. The spatial connection of the two parameters SUV max and ADC min has a crucial influence on their numeric correlation.
NASA Astrophysics Data System (ADS)
Sugihara, Kenkoh
2009-10-01
A low-cost ADC (Analogue-to-Digital Converter) with shaping embedded for undergraduate physics laboratory is developed using a home made circuit and a PC sound card. Even though an ADC is needed as an essential part of an experimental set up, commercially available ones are very expensive and are scarce for undergraduate laboratory experiments. The system that is developed from the present work is designed for a gamma-ray spectroscopy laboratory with NaI(Tl) counters, but not limited. For this purpose, the system performance is set to sampling rate of 1-kHz with 10-bit resolution using a typical PC sound card with 41-kHz or higher sampling rate and 16-bit resolution ADC with an addition of a shaping circuit. Details of the system and the status of development will be presented. Ping circuit and PC soundcard as typical PC sound card has 41.1kHz or heiger sampling rate and 16bit resolution ADCs. In the conference details of the system and the status of development will be presented.
Target-mediated drug disposition model and its approximations for antibody-drug conjugates.
Gibiansky, Leonid; Gibiansky, Ekaterina
2014-02-01
Antibody-drug conjugate (ADC) is a complex structure composed of an antibody linked to several molecules of a biologically active cytotoxic drug. The number of ADC compounds in clinical development now exceeds 30, with two of them already on the market. However, there is no rigorous mechanistic model that describes pharmacokinetic (PK) properties of these compounds. PK modeling of ADCs is even more complicated than that of other biologics as the model should describe distribution, binding, and elimination of antibodies with different toxin load, and also the deconjugation process and PK of the released toxin. This work extends the target-mediated drug disposition (TMDD) model to describe ADCs, derives the rapid binding (quasi-equilibrium), quasi-steady-state, and Michaelis-Menten approximations of the TMDD model as applied to ADCs, derives the TMDD model and its approximations for ADCs with load-independent properties, and discusses further simplifications of the system under various assumptions. The developed models are shown to describe data simulated from the available clinical population PK models of trastuzumab emtansine (T-DM1), one of the two currently approved ADCs. Identifiability of model parameters is also discussed and illustrated on the simulated T-DM1 examples.
Beam Instrument Development System
DOE Office of Scientific and Technical Information (OSTI.GOV)
DOOLITTLE, LAWRENCE; HUANG, GANG; DU, QIANG
Beam Instrumentation Development System (BIDS) is a collection of common support libraries and modules developed during a series of Low-Level Radio Frequency (LLRF) control and timing/synchronization projects. BIDS includes a collection of Hardware Description Language (HDL) libraries and software libraries. The BIDS can be used for the development of any FPGA-based system, such as LLRF controllers. HDL code in this library is generic and supports common Digital Signal Processing (DSP) functions, FPGA-specific drivers (high-speed serial link wrappers, clock generation, etc.), ADC/DAC drivers, Ethernet MAC implementation, etc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prager, Stefan, E-mail: stefan.prager@iwr.uni-heidelberg.de; Dreuw, Andreas, E-mail: dreuw@uni-heidelberg.de; Zech, Alexander, E-mail: alexander.zech@unige.ch
The combination of Frozen Density Embedding Theory (FDET) and the Algebraic Diagrammatic Construction (ADC) scheme for the polarization propagator for describing environmental effects on electronically excited states is presented. Two different ways of interfacing and expressing the so-called embedding operator are introduced. The resulting excited states are compared with supermolecular calculations of the total system at the ADC(2) level of theory. Molecular test systems were chosen to investigate molecule–environment interactions of varying strength from dispersion interaction up to multiple hydrogen bonds. The overall difference between the supermolecular and the FDE-ADC calculations in excitation energies is lower than 0.09 eV (max)more » and 0.032 eV in average, which is well below the intrinsic error of the ADC(2) method itself.« less
El Kady, Reem M; Choudhary, Arabinda Kumar; Tappouni, Rafel
2011-03-01
The purpose of this article is to evaluate the accuracy of apparent diffusion coefficient (ADC) measurements made with a PACS workstation compared with measurements made with a dedicated workstation, which is currently considered the reference standard. A retrospective review was performed in liver lesions from 79 patients using three MRI platforms. The final diagnosis was established by liver biopsy in 31 patients and by dynamic MRI and follow-up, both clinical and radiologic as indicated, in 48 patients. Each lesion that was clearly demonstrable on the ADC map was measured with a commercial dedicated postprocessing workstation and again with a PACS system. A two-sample t test was used to determine the statistically significant differences between the two ADC measurements. A total of 79 patients with 120 liver lesions were included. ADC values measured on the workstation were 0.4-4.38 × 10(-3) mm(2)/s. The ADC values measured on the PACS were 0.42-4.35 × 10(-3) mm(2)/s. The T value was -1.113, with 119 degrees of freedom, and the significance level was 0.268, which implies no significant difference between the two different measuring systems for all pathologic abnormalities and MRI scanners used. ADC values measured on a routine PACS workstation are as accurate as the values obtained on a dedicated specialized workstation. ADC value measurement on the routine PACS will save time and lead to increased utilization, which, in turn, will lead to an improved understanding of the different disease processes and their clinical management.
PI-RADS v2 and ADC values: is there room for improvement?
Jordan, Eric J; Fiske, Charles; Zagoria, Ronald; Westphalen, Antonio C
2018-03-17
To determine the diagnostic accuracy of ADC values in combination with PI-RADS v2 for the diagnosis of clinically significant prostate cancer (CS-PCa) compared to PI-RADS v2 alone. This retrospective study included 155 men whom underwent 3-Tesla prostate MRI and subsequent MR/US fusion biopsies at a single non-academic center from 11/2014 to 3/2016. All scans were performed with a surface coil and included T2, diffusion-weighted, and dynamic contrast-enhanced sequences. Suspicious findings were classified using Prostate Imaging Reporting and Data System (PI-RADS) v2 and targeted using MR/US fusion biopsies. Mixed-effect logistic regression analyses were used to determine the ability of PIRADS v2 alone and combined with ADC values to predict CS-PCa. As ADC categories are more practical in clinical situations than numeric values, an additional model with ADC categories of ≤ 800 and > 800 was performed. A total of 243 suspicious lesions were included, 69 of which were CS-PCa, 34 were Gleason score 3+3 PCa, and 140 were negative. The overall PIRADS v2 score, ADC values, and ADC categories are independent statistically significant predictors of CS-PCa (p < 0.001). However, the area under the ROC of PIRADS v2 alone and PIRADS v2 with ADC categories are significantly different in both peripheral and transition zone lesions (p = 0.026 and p = 0.03, respectively) Further analysis of the ROC curves also shows that the main benefit of utilizing ADC values or categories is better discrimination of PI-RADS v2 4 lesions. ADC values and categories help to diagnose CS-PCa when lesions are assigned a PI-RADS v2 score of 4.
The Flash ADC system and PMT waveform reconstruction for the Daya Bay experiment
NASA Astrophysics Data System (ADS)
Huang, Yongbo; Chang, Jinfan; Cheng, Yaping; Chen, Zhang; Hu, Jun; Ji, Xiaolu; Li, Fei; Li, Jin; Li, Qiuju; Qian, Xin; Jetter, Soeren; Wang, Wei; Wang, Zheng; Xu, Yu; Yu, Zeyuan
2018-07-01
To better understand the energy response of the Antineutrino Detector (AD), the Daya Bay Reactor Neutrino Experiment installed a full Flash ADC readout system on one AD that allowed for simultaneous data taking with the current readout system. This paper presents the design, data acquisition, and simulation of the Flash ADC system, and focuses on the PMT waveform reconstruction algorithms. For liquid scintillator calorimetry, the most critical requirement to waveform reconstruction is linearity. Several common reconstruction methods were tested but the linearity performance was not satisfactory. A new method based on the deconvolution technique was developed with 1% residual non-linearity, which fulfills the requirement. The performance was validated with both data and Monte Carlo (MC) simulations, and 1% consistency between them has been achieved.
Continuous Time Level Crossing Sampling ADC for Bio-Potential Recording Systems
Tang, Wei; Osman, Ahmad; Kim, Dongsoo; Goldstein, Brian; Huang, Chenxi; Martini, Berin; Pieribone, Vincent A.
2013-01-01
In this paper we present a fixed window level crossing sampling analog to digital convertor for bio-potential recording sensors. This is the first proposed and fully implemented fixed window level crossing ADC without local DACs and clocks. The circuit is designed to reduce data size, power, and silicon area in future wireless neurophysiological sensor systems. We built a testing system to measure bio-potential signals and used it to evaluate the performance of the circuit. The bio-potential amplifier offers a gain of 53 dB within a bandwidth of 200 Hz-20 kHz. The input-referred rms noise is 2.8 µV. In the asynchronous level crossing ADC, the minimum delta resolution is 4 mV. The input signal frequency of the ADC is up to 5 kHz. The system was fabricated using the AMI 0.5 µm CMOS process. The chip size is 1.5 mm by 1.5 mm. The power consumption of the 4-channel system from a 3.3 V supply is 118.8 µW in the static state and 501.6 µW with a 240 kS/s sampling rate. The conversion efficiency is 1.6 nJ/conversion. PMID:24163640
Malyarenko, Dariya I; Wilmes, Lisa J; Arlinghaus, Lori R; Jacobs, Michael A; Huang, Wei; Helmer, Karl G; Taouli, Bachir; Yankeelov, Thomas E; Newitt, David; Chenevert, Thomas L
2016-12-01
Previous research has shown that system-dependent gradient nonlinearity (GNL) introduces a significant spatial bias (nonuniformity) in apparent diffusion coefficient (ADC) maps. Here, the feasibility of centralized retrospective system-specific correction of GNL bias for quantitative diffusion-weighted imaging (DWI) in multisite clinical trials is demonstrated across diverse scanners independent of the scanned object. Using corrector maps generated from system characterization by ice-water phantom measurement completed in the previous project phase, GNL bias correction was performed for test ADC measurements from an independent DWI phantom (room temperature agar) at two offset locations in the bore. The precomputed three-dimensional GNL correctors were retrospectively applied to test DWI scans by the central analysis site. The correction was blinded to reference DWI of the agar phantom at magnet isocenter where the GNL bias is negligible. The performance was evaluated from changes in ADC region of interest histogram statistics before and after correction with respect to the unbiased reference ADC values provided by sites. Both absolute error and nonuniformity of the ADC map induced by GNL (median, 12%; range, -35% to +10%) were substantially reduced by correction (7-fold in median and 3-fold in range). The residual ADC nonuniformity errors were attributed to measurement noise and other non-GNL sources. Correction of systematic GNL bias resulted in a 2-fold decrease in technical variability across scanners (down to site temperature range). The described validation of GNL bias correction marks progress toward implementation of this technology in multicenter trials that utilize quantitative DWI.
Malyarenko, Dariya I.; Wilmes, Lisa J.; Arlinghaus, Lori R.; Jacobs, Michael A.; Huang, Wei; Helmer, Karl G.; Taouli, Bachir; Yankeelov, Thomas E.; Newitt, David; Chenevert, Thomas L.
2017-01-01
Previous research has shown that system-dependent gradient nonlinearity (GNL) introduces a significant spatial bias (nonuniformity) in apparent diffusion coefficient (ADC) maps. Here, the feasibility of centralized retrospective system-specific correction of GNL bias for quantitative diffusion-weighted imaging (DWI) in multisite clinical trials is demonstrated across diverse scanners independent of the scanned object. Using corrector maps generated from system characterization by ice-water phantom measurement completed in the previous project phase, GNL bias correction was performed for test ADC measurements from an independent DWI phantom (room temperature agar) at two offset locations in the bore. The precomputed three-dimensional GNL correctors were retrospectively applied to test DWI scans by the central analysis site. The correction was blinded to reference DWI of the agar phantom at magnet isocenter where the GNL bias is negligible. The performance was evaluated from changes in ADC region of interest histogram statistics before and after correction with respect to the unbiased reference ADC values provided by sites. Both absolute error and nonuniformity of the ADC map induced by GNL (median, 12%; range, −35% to +10%) were substantially reduced by correction (7-fold in median and 3-fold in range). The residual ADC nonuniformity errors were attributed to measurement noise and other non-GNL sources. Correction of systematic GNL bias resulted in a 2-fold decrease in technical variability across scanners (down to site temperature range). The described validation of GNL bias correction marks progress toward implementation of this technology in multicenter trials that utilize quantitative DWI. PMID:28105469
Deka, G; Bharath, S R; Savithri, H S; Murthy, M R N
2017-09-02
Enteric pathogens such as Salmonella typhimurium colonize the human gut in spite of the lethal acidic pH environment (pH < 2.5) due to the activation of inducible acid tolerance response (ATR) systems. The pyridoxal 5'-phosphate (PLP)-dependent enzyme, biodegradative arginine decarboxylase (ADC, encoded by AdiA), is a component of an ATR system. The enzyme consumes a cytoplasmic proton in the process of arginine degradation to agmatine. Arginine-agmatine antiporter (AdiC) exchanges the product agmatine for arginine. In this manuscript, we describe the structure of Salmonella typhimurium ADC (StADC). The decameric structure assembled from five dimers related by a non crystallographic 5-fold symmetry represents the first apo-form of the enzyme. The structure suggests that PLP-binding is not a prerequisite for oligomerization. Comparison with E. coli ADC reveals that PLP-binding is accompanied by the movement and ordering of two loops (residues 150-159 and 191-197) and a few active site residues such as His256 and Lys257. A number of residues important for substrate binding are disordered in the apo-StADC structure indicating that PLP binding is important for substrate binding. Unlike the interactions between 5-fold related protomers, interactions that stabilize the dimeric structure are not pH dependent. Copyright © 2017 Elsevier Inc. All rights reserved.
Cuevas, Juan C.; López-Cobollo, Rosa; Alcázar, Rubén; Zarza, Xavier; Koncz, Csaba; Altabella, Teresa; Salinas, Julio; Tiburcio, Antonio F.; Ferrando, Alejandro
2008-01-01
The levels of endogenous polyamines have been shown to increase in plant cells challenged with low temperature; however, the functions of polyamines in the regulation of cold stress responses are unknown. Here, we show that the accumulation of putrescine under cold stress is essential for proper cold acclimation and survival at freezing temperatures because Arabidopsis (Arabidopsis thaliana) mutants defective in putrescine biosynthesis (adc1, adc2) display reduced freezing tolerance compared to wild-type plants. Genes ADC1 and ADC2 show different transcriptional profiles upon cold treatment; however, they show similar and redundant contributions to cold responses in terms of putrescine accumulation kinetics and freezing sensitivity. Our data also demonstrate that detrimental consequences of putrescine depletion during cold stress are due, at least in part, to alterations in the levels of abscisic acid (ABA). Reduced expression of NCED3, a key gene involved in ABA biosynthesis, and down-regulation of ABA-regulated genes are detected in both adc1 and adc2 mutant plants under cold stress. Complementation analysis of adc mutants with ABA and reciprocal complementation tests of the aba2-3 mutant with putrescine support the conclusion that putrescine controls the levels of ABA in response to low temperature by modulating ABA biosynthesis and gene expression. PMID:18701673
Zhao, Cailei; Li, Yongxin; Cao, Weiguo; Xiang, Kui; Zhang, Heye; Yang, Jian; Gan, Yungen
2016-01-01
Abstract To explore the use of diffusion tensor imaging (DTI) parameters in the quantitative assessment of early brain microstructure changes before and after ventriculoperitoneal shunt in children with high intracranial pressure hydrocephalus. Ten patients with communicating hydrocephalus (age: 2–36 months) and 14 age-/gender-matched controls (age: 2–36 months) were enrolled in this study. All patients underwent the ventriculoperitoneal shunt procedure. The imaging data were collected before and 3 months after the operation. Regions of interests (ROIs) included the white matter near the frontal horn of the lateral ventricles (FHLV), the occipital horn of the lateral ventricles (OHLV), occipital subcortical (OS) area, frontal subcortical (FS) area, and thalamus. Fractional anisotropies (FA) and apparent diffusion coefficients (ADC) of the ROIs before and after ventriculoperitoneal shunt were compared between the patients and the controls. Three months after surgery, the patients recovered from the surgery with ameliorated intracranial pressure and slight improvement of clinical intelligence scale and motor scale. Before ventriculoperitoneal shunt, the FA values (except the right FHLV) were significantly decreased and the ADC values were significantly increased in the patients with hydrocephalus, compared with the controls. After the ventriculoperitoneal shunt, the FA values in the FHLV and OHLV of the patients were similar to the controls, but the FA values in other ROIs were still significantly lower than controls. The ADC values in the FS and OS white matter areas of the patients were similar to the controls; however, the ADC values in other ROIs were still significantly higher in patients. The increase of FA and the reduction in ADC in the ROIs preceded the clinical function improvement in patients with high intracranial pressure hydrocephalus and reflected the early changes in brain tissue microstructure, such as the compression of the white matter areas in the ROIs. PMID:27759635
Xu, Kun; Song, Yufeng; Dai, Lianpan; Zhang, Yongli; Lu, Xuancheng; Xie, Yijia; Zhang, Hangjie; Cheng, Tao; Wang, Qihui; Huang, Qingrui; Bi, Yuhai; Liu, William J; Liu, Wenjun; Li, Xiangdong; Qin, Chuan; Shi, Yi; Yan, Jinghua; Zhou, Dongming; Gao, George F
2018-03-15
The recent outbreak of Zika virus (ZIKV) has emerged as a global health concern. ZIKV can persist in human semen and be transmitted by sexual contact, as well as by mosquitoes, as seen for classical arboviruses. We along with others have previously demonstrated that ZIKV infection leads to testis damage and infertility in mouse models. So far, no prophylactics or therapeutics are available; therefore, vaccine development is urgently demanded. Recombinant chimpanzee adenovirus has been explored as the preferred vaccine vector for many pathogens due to the low preexisting immunity against the vector among the human population. Here, we developed a ZIKV vaccine based on recombinant chimpanzee adenovirus type 7 (AdC7) expressing ZIKV M/E glycoproteins. A single vaccination of AdC7-M/E was sufficient to elicit potent neutralizing antibodies and protective immunity against ZIKV in both immunocompetent and immunodeficient mice. Moreover, vaccinated mice rapidly developed neutralizing antibody with high titers within 1 week postvaccination, and the elicited antiserum could cross-neutralize heterologous ZIKV strains. Additionally, ZIKV M- and E-specific T cell responses were robustly induced by AdC7-M/E. Moreover, one-dose inoculation of AdC7-M/E conferred mouse sterilizing immunity to eliminate viremia and viral burden in tissues against ZIKV challenge. Further investigations showed that vaccination with AdC7-M/E completely protected against ZIKV-induced testicular damage. These data demonstrate that AdC7-M/E is highly effective and represents a promising vaccine candidate for ZIKV control. IMPORTANCE Zika virus (ZIKV) is a pathogenic flavivirus that causes severe clinical consequences, including congenital malformations in fetuses and Guillain-Barré syndrome in adults. Vaccine development is a high priority for ZIKV control. In this study, to avoid preexisting anti-vector immunity in humans, a rare serotype chimpanzee adenovirus (AdC7) expressing the ZIKV M/E glycoproteins was used for ZIKV vaccine development. Impressively, AdC7-M/E exhibited exceptional performance as a ZIKV vaccine, as follows: (i) protective efficacy by a single vaccination, (ii) rapid development of a robust humoral response, (iii) durable immune responses, (iv) robust T cell responses, and (v) sterilizing immunity achieved by a single vaccination. These advantages of AdC7-M/E strongly support its potential application as a promising ZIKV vaccine in the clinic. Copyright © 2018 American Society for Microbiology.
Brain-water diffusion coefficients reflect the severity of inherited prion disease
Hyare, H.; Wroe, S.; Siddique, D.; Webb, T.; Fox, N. C.; Stevens, J.; Collinge, J.; Yousry, T.; Thornton, J. S.
2010-01-01
Objective: Inherited prion diseases are progressive neurodegenerative conditions, characterized by cerebral spongiosis, gliosis, and neuronal loss, caused by mutations within the prion protein (PRNP) gene. We wished to assess the potential of diffusion-weighted MRI as a biomarker of disease severity in inherited prion diseases. Methods: Twenty-five subjects (mean age 45.2 years) with a known PRNP mutation including 19 symptomatic patients, 6 gene-positive asymptomatic subjects, and 7 controls (mean age 54.1 years) underwent conventional and diffusion-weighted MRI. An index of normalized brain volume (NBV) and region of interest (ROI) mean apparent diffusion coefficient (ADC) for the head of caudate, putamen, and pulvinar nuclei were recorded. ADC histograms were computed for whole brain (WB) and gray matter (GM) tissue fractions. Clinical assessment utilized standardized clinical scores. Mann-Whitney U test and regression analyses were performed. Results: Symptomatic patients exhibited an increased WB mean ADC (p = 0.006) and GM mean ADC (p = 0.024) compared to controls. Decreased NBV and increased mean ADC measures significantly correlated with clinical measures of disease severity. Using a stepwise multivariate regression procedure, GM mean ADC was an independent predictor of Clinician's Dementia Rating score (p = 0.001), Barthel Index of activities of daily living (p = 0.001), and Rankin disability score (p = 0.019). Conclusions: Brain volume loss in inherited prion diseases is accompanied by increased cerebral apparent diffusion coefficient (ADC), correlating with increased disease severity. The association between gray matter ADC and clinical neurologic status suggests this measure may prove a useful biomarker of disease activity in inherited prion diseases. GLOSSARY ADAS-Cog = Alzheimer's Disease Assessment Scale–Cognitive subscale; ADC = apparent diffusion coefficient; ADL = Barthel Activities of Daily Living scale; BET = brain extraction tool; BPRS = Brief Psychiatric Rating Scale; BSE = bovine spongiform encephalopathy; CDR = Clinician's Dementia Rating Scale; CGIS = Clinician's Global Impression of Disease; CI = confidence interval; DWI = diffusion-weighted imaging; FLAIR = fluid-attenuated inversion recovery; FOV = field of view; GM = gray matter; LC = left head of caudate; LP = left putamen; LPu = left pulvinar; MMSE = Mini-Mental State Examination; NBV = normalized brain volume; PH = peak height; PL = peak location; RC = right head of caudate; RP = right putamen; RPu = right pulvinar; ROI = region of interest; sCJD = sporadic Creutzfeldt-Jakob disease; TE = echo time; TI = inversion time; TR = repetition time; vCJD = variant Creutzfeldt-Jakob disease; WB = whole brain; WM = white matter. PMID:20177119
Gao, Yu; Han, Fei; Zhou, Ziwu; Cao, Minsong; Kaprealian, Tania; Kamrava, Mitchell; Wang, Chenyang; Neylon, John; Low, Daniel A; Yang, Yingli; Hu, Peng
2017-10-01
Monitoring tumor response during the course of treatment and adaptively modifying treatment plan based on tumor biological feedback may represent a new paradigm for radiotherapy. Diffusion MRI has shown great promises in assessing and predicting tumor response to radiotherapy. However, the conventional diffusion-weighted single-shot echo-planar-imaging (DW-ssEPI) technique suffers from limited resolution, severe distortion, and possibly inaccurate ADC at low field strength. The purpose of this work was to develop a reliable, accurate and distortion-free diffusion MRI technique that is practicable for longitudinal tumor response evaluation and adaptive radiotherapy on a 0.35 T MRI-guided radiotherapy system. A diffusion-prepared turbo spin echo readout (DP-TSE) sequence was developed and compared with the conventional diffusion-weighted single-shot echo-planar-imaging sequence on a 0.35 T MRI-guided radiotherapy system (ViewRay). A spatial integrity phantom was used to quantitate and compare the geometric accuracy of the two diffusion sequences for three orthogonal orientations. The apparent diffusion coefficient (ADC) accuracy was evaluated on a diffusion phantom under both 0 °C and room temperature to cover a diffusivity range between 0.40 × 10 -3 and 2.10 × 10 -3 mm 2 /s. Ten room temperature measurements repeated on five different days were conducted to assess the ADC reproducibility of DP-TSE. Two glioblastoma (GBM) and six sarcoma patients were included to examine the in vivo feasibility. The target registration error (TRE) was calculated to quantitate the geometric accuracy where structural CT or MR images were co-registered to the diffusion images as references. ADC maps from DP-TSE and DW-ssEPI were calculated and compared. A tube phantom was placed next to patients not treated on ViewRay, and ADCs of this reference tube were also compared. The proposed DP-TSE passed the spatial integrity test (< 1 mm within 100 mm radius and < 2 mm within 175 mm radius) under the three orthogonal orientations. The detected errors were 0.474 ± 0.355 mm, 0.475 ± 0.287 mm, and 0.546 ± 0.336 mm in the axial, coronal, and sagittal plane. DW-ssEPI, however, failed the tests due to severe distortion and low signal intensity. Noise correction must be performed for the DW-ssEPI to avoid ADC quantitation errors, whereas it is optional for DP-TSE. At 0 °C, the two sequences provided accurate quantitation with < 3% variation with the reference. In the room temperature study, discrepancies between ADCs from DP-TSE and the reference were within 4%, but could be as high as 8% for DW-ssEPI after the noise correction. Excellent ADC reproducibility with a coefficient of variation < 5% was observed among the 10 measurements of DP-TSE, indicating desirable robustness for ADC-based tumor response assessment. In vivo TRE in DP-TSE was less than 1.6 mm overall, whereas it could be greater than 12 mm in DW-ssEPI. For GBM patients, the CSF and brain tissue ADCs from DP-TSE were within the ranges found in literature. ADC differences between the two techniques were within 8% among the six sarcoma patients. For the reference tube that had a relatively low diffusivity, the two diffusion sequences provided matched measurements. A diffusion technique with excellent geometric fidelity, accurate, and reproducible ADC measurement was demonstrated for longitudinal tumor response assessment using a low-field MRI-guided radiotherapy system. © 2017 American Association of Physicists in Medicine.
Communication Impairment in the AIDS Dementia Complex (ADC): A Case Report
ERIC Educational Resources Information Center
McCabe, Patricia J.; Sheard, Christine; Code, Chris
2008-01-01
This article details three examinations of communication impairment over 13 months in a man with AIDS dementia complex (ADC) and compares his performance on standardised language testing with that of two control participants. He had mild language impairments as measured on standardised tests but was severely impaired in pragmatic language skills.…
Correlation of ADC value with pathologic indexes in colorectal tumor homografts in Balb/c mouse.
Li, Xiaojun; Jiang, Hongnan; Niu, Jinliang; Zheng, Ying
2014-08-01
Noninvasive diffusion-weighted magnetic resonance imaging (DWI) is a well-studied MR imaging technique for quantifying water diffusion especially in tumor area. The correlation between apparent diffusion coefficient (ADC) value and apoptosis or proliferation is not clear by now. This study aimed to investigate whether DWI-ADC value could be used as an imaging marker related with pathologic indexes of tumors. A total of 30 Balb/c mice with HT29 colorectal carcinoma were subjected to DWI and histologic analysis. The percentage of ADC changes and the apoptotic and proliferating indexes were calculated at predefined time points. Kolmogorov-Smirnov distances were considered to determine whether the percentage of ADC changes, and the apoptotic and proliferating indexes were normally distributed. An independent-samples t-test was used to analyze the difference between apoptotic and proliferating indexes in the two groups. THERE WAS A STATISTICALLY SIGNIFICANT DIFFERENCE IN PROLIFERATING INDEX BETWEEN THE RADIOTHERAPY AND CONTROL GROUPS (MEAN PROLIFERATING INDEX: 49.27% vs. 83.09%), and there was a statistically significant difference in apoptotic index between the two groups (mean apoptotic index: 37.7% vs. 2.71%). A significant positive correlation was found between the percentage of ADC changes of the viable tissue and apoptotic index. Pearson's correlation coefficient was 0.655 (P=0.015). A significant negative correlation was found between the percentage of ADC changes of the viable tissue and ki-67 proliferation index. Pearson's correlation coefficient was 0.734 (P<0.001). Our results suggest that ADC value may be used in measurement of cell apoptotic and proliferating indexes in colorectal carcinoma.
Kim, Mimi; Kang, Tae Wook; Kim, Young Kon; Kim, Seong Hyun; Kwon, Wooil; Ha, Sang Yun; Ji, Sang A
2016-03-01
To evaluate the correlation between grade of pancreatic neuroendocrine tumours (pNETs) based on the 2010 World Health Organization (WHO) classification and the apparent diffusion coefficient (ADC), and to assess whether the ADC value and WHO classification can predict recurrence-free survival (RFS) after surgery for pNETs. This retrospective study was approved by the Institutional Review Board. The requirement for informed consent was waived. Between March 2009 and November 2014, forty-nine patients who underwent magnetic resonance (MR) imaging with diffusion-weighted image and subsequent surgery for single pNETs were included. Correlations among qualitative MR imaging findings, quantitative ADC values, and WHO classifications were assessed. An ordered logistic regression test was used to control for tumour size as a confounding factor. The association between ADC value (or WHO classification) and RFS was analysed. All tumors (n=49) were classified as low- (n=29, grade 1), intermediate- (n=17, grade 2), and high-grade (n=3, grade 3), respectively. The mean ADC of pNETs was moderately negatively correlated with WHO classification before and after adjustment for tumour size (ρ=-0.64, p<0.001 and ρ=-0.55, p=0.001 respectively). RFS was significantly associated with WHO classification (p=0.007), but not with the ADC value (p=0.569). The ADC value of pNETs is moderately correlated with WHO tumour grade, regardless of tumour size. However, the WHO tumour classification of pNET may be more suitable for predicting RFS than the ADC value. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Gikanga, Benson; Adeniji, Nia S; Patapoff, Thomas W; Chih, Hung-Wei; Yi, Li
2016-04-20
Antibody-drug conjugates (ADCs) require thorough characterization and understanding of product quality attributes. The framework of many ADCs comprises one molecule of antibody that is usually conjugated with multiple drug molecules at various locations. It is unknown whether the drug release rate from the ADC is dependent on drug location, and/or local environment, dictated by the sequence and structure of the antibody carrier. This study addresses these issues with valine-citrulline-monomethylauristatin E (vc-MMAE)-based ADC molecules conjugated at reduced disulfide bonds, by evaluating the cathepsin B catalyzed drug release rate of ADC molecules with different drug distributions or antibody carriers. MMAE drug release rates at different locations on ADC I were compared to evaluate the impact of drug location. No difference in rates was observed for drug released from the V(H), V(L), or C(H)2 domains of ADC I. Furthermore, four vc-MMAE ADC molecules were chosen as substrates for cathepsin B for evaluation of Michaelis-Menten parameters. There was no significant difference in K(M) or k(cat) values, suggesting that different sequences of the antibody carrier do not result in different drug release rates. Comparison between ADCs and small molecules containing vc-MMAE moieties as substrates for cathepsin B suggests that the presence of IgG1 antibody carrier, regardless of its bulkiness, does not impact drug release rate. Finally, a molecular dynamics simulation on ADC II revealed that the val-cit moiety at each of the eight possible conjugation sites was, on average, solvent accessible over 50% of its maximum solvent accessible surface area (SASA) during a 500 ns trajectory. Combined, these results suggest that the cathepsin cleavage sites for conjugated drugs are exposed enough for the enzyme to access and that the drug release rate is rather independent of drug location or monoclonal antibody carrier. Therefore, the distribution of drug conjugation at different sites is not a critical parameter to control in manufacturing of the vc-MMAE-based ADC conjugated at reduced disulfide bonds.
Samanci, C; Alis, D; Ustabasioglu, F E; Ozmen, E; Ucar, A K; Aslan, M; Habibi, H A; Bakan, S; Ozcabi, B; Evliyaoğlu, S O; Adaletli, I
2017-01-01
The purpose of this study was to assess the diagnostic value of measuring the apparent diffusion coefficient (ADC) of ovarian stroma in polycystic ovary syndrome (PCOS). This study was approved by the institutional review board and informed consent was obtained from each women. A total of 17 women (mean age, 22.2 years±5.1 [SD]; range, 16-33 years) with a diagnosis of PCOS according to the Androgen Excess and PCOS Society criteria and 18 healthy women (mean age, 22.8 years±5.2 [SD]; range, 16-31 years) who served as a control group were included in this prospective study. ADC values of the ovarian stroma during the early follicular phase were calculated by two observers in the two groups. Comparisons were performed using the Student t-test. The mean ADC value in woman with PCOS (1.29±0.27×10 -3 mm 2 /s; range: 0.59×10 -3 - 1.88×10 -3 mm 2 /s) was significantly lower than that in the control group (1.48±0.17×10 -3 mm 2 /s; range: 1.12×10 -3 - 1.86×10 -3 mm 2 /s) (P<0.001). The ADC cutoff value for the determination of PCOS with maximum accuracy was 1.38×10 -3 mm 2 /s (AUC: 0.720; 95% CI: 0.597, 0.843), yielding 78% sensitivity and 62.9% specificity. ADC values of ovarian stroma are lower in patients with PCOS than in control subjects. ADC measurement of ovarian stroma in women with PCOS might help improve the diagnosis of PCOS. Copyright © 2016 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Sagiyama, Koji; Watanabe, Yuji; Kamei, Ryotaro; Hong, Sungtak; Kawanami, Satoshi; Matsumoto, Yoshihiro; Honda, Hiroshi
2017-12-01
To investigate the usefulness of voxel-based analysis of standardized uptake values (SUVs) and apparent diffusion coefficients (ADCs) for evaluating soft-tissue tumour malignancy with a PET/MR system. Thirty-five subjects with either ten low/intermediate-grade tumours or 25 high-grade tumours were prospectively enrolled. Zoomed diffusion-weighted and fluorodeoxyglucose ( 18 FDG)-PET images were acquired along with fat-suppressed T2-weighted images (FST2WIs). Regions of interest (ROIs) were drawn on FST2WIs including the tumour in all slices. ROIs were pasted onto PET and ADC-maps to measure SUVs and ADCs within tumour ROIs. Tumour volume, SUVmax, ADCminimum, the heterogeneity and the correlation coefficients of SUV and ADC were recorded. The parameters of high- and low/intermediate-grade groups were compared, and receiver operating characteristic (ROC) analysis was also performed. The mean correlation coefficient for SUV and ADC in high-grade sarcomas was lower than that of low/intermediate-grade tumours (-0.41 ± 0.25 vs. -0.08 ± 0.34, P < 0.01). Other parameters did not differ significantly. ROC analysis demonstrated that correlation coefficient showed the best diagnostic performance for differentiating the two groups (AUC 0.79, sensitivity 96.0%, specificity 60%, accuracy 85.7%). SUV and ADC determined via PET/MR may be useful for differentiating between high-grade and low/intermediate-grade soft tissue tumours. • PET/MR allows voxel-based comparison of SUVs and ADCs in soft-tissue tumours. • A comprehensive assessment of internal heterogeneity was performed with scatter plots. • SUVmax or ADCminimum could not differentiate high-grade sarcoma from low/intermediate-grade tumours. • Only the correlation coefficient between SUV and ADC differentiated the two groups. • The correlation coefficient showed the best diagnostic performance by ROC analysis.
Zhang, Wei; Zhou, Yue; Xu, Xiao-Quan; Kong, Ling-Yan; Xu, Hai; Yu, Tong-Fu; Shi, Hai-Bin; Feng, Qing
2018-01-01
To assess the performance of a whole-tumor histogram analysis of apparent diffusion coefficient (ADC) maps in differentiating thymic carcinoma from lymphoma, and compare it with that of a commonly used hot-spot region-of-interest (ROI)-based ADC measurement. Diffusion weighted imaging data of 15 patients with thymic carcinoma and 13 patients with lymphoma were retrospectively collected and processed with a mono-exponential model. ADC measurements were performed by using a histogram-based and hot-spot-ROI-based approach. In the histogram-based approach, the following parameters were generated: mean ADC (ADC mean ), median ADC (ADC median ), 10th and 90th percentile of ADC (ADC 10 and ADC 90 ), kurtosis, and skewness. The difference in ADCs between thymic carcinoma and lymphoma was compared using a t test. Receiver operating characteristic analyses were conducted to determine and compare the differentiating performance of ADCs. Lymphoma demonstrated significantly lower ADC mean , ADC median , ADC 10 , ADC 90 , and hot-spot-ROI-based mean ADC than those found in thymic carcinoma (all p values < 0.05). There were no differences found in the kurtosis ( p = 0.412) and skewness ( p = 0.273). The ADC 10 demonstrated optimal differentiating performance (cut-off value, 0.403 × 10 -3 mm 2 /s; area under the receiver operating characteristic curve [AUC], 0.977; sensitivity, 92.3%; specificity, 93.3%), followed by the ADC mean , ADC median , ADC 90 , and hot-spot-ROI-based mean ADC. The AUC of ADC 10 was significantly higher than that of the hot spot ROI based ADC (0.977 vs. 0.797, p = 0.036). Compared with the commonly used hot spot ROI based ADC measurement, a histogram analysis of ADC maps can improve the differentiating performance between thymic carcinoma and lymphoma.
Pérez-Sánchez, José M.; Rodríguez, Ignacio; Ruiz-Cabello, Jesús
2009-01-01
Abstract Apparent diffusion coefficient (ADC) measurement in the lung using gas magnetic resonance imaging is a promising technique with potential for reflecting changes in lung microstructure. Despite some recent impressive human applications, full interpretation of ADC measures remains an elusive goal, due to a lack of detailed knowledge about the structure dependency of ADC. In an attempt to fill this gap we have performed random walk simulations in a three-dimensional geometrical model of the lung acinus, the distal alveolated sections of the lung tree accounting for ∼90% of the total lung volume. Simulations were carried out adjusting model parameters after published morphological data for the rat peripheral airway system, which predict an ADC behavior as microstructure changes with lung inflation in partial agreement with measured ADCs at different airway pressures. The approach used to relate experimental ADCs to lung microstructural changes does not make any assumption about the cause of the changes, so it could be applied to other scenarios such as chronic obstructive pulmonary disease, lung development, etc. The work presented here predicts numerically for the first time ADC values measured in the lung from independent morphological measures of lung microstructure taken at different inflation stages during the breath cycle. PMID:19619480
Umemura, Atsushi; Oeda, Tomoko; Hayashi, Ryutaro; Tomita, Satoshi; Kohsaka, Masayuki; Yamamoto, Kenji; Sawada, Hideyuki
2013-01-01
It is often hard to differentiate Parkinson's disease (PD) and parkinsonian variant of multiple system atrophy (MSA-P), especially in the early stages. Cardiac sympathetic denervation and putaminal rarefaction are specific findings for PD and MSA-P, respectively. We investigated diagnostic accuracy of putaminal apparent diffusion coefficient (ADC) test for MSA-P and (123)I-metaiodobenzylguanidine (MIBG) scintigram for PD, especially in early-stage patients. The referral standard diagnosis of PD and MSA-P were the diagnostic criteria of the United Kingdom Parkinson's Disease Society Brain Bank Criteria and the second consensus criteria, respectively. Based on the referral standard criteria, diagnostic accuracy [area under the receiver-operator characteristic curve (AUC), sensitivity and specificity] of the ADC and MIBG tests was estimated retrospectively. Diagnostic accuracy of these tests performed within 3 years of symptom onset was also investigated. ADC and MIBG tests were performed on 138 patients (20 MSA and 118 PD). AUC was 0.95 and 0.83 for the ADC and MIBG tests, respectively. Sensitivity and specificity were 85.0% and 89.0% for MSA-P diagnosis by ADC test and 67.0% and 80.0% for PD diagnosis by MIBG test. When these tests were restricted to patients with disease duration ≤ 3 years, the sensitivity and specificity were 75.0% and 91.4% for the ADC test (MSA-P diagnosis) and 47.7% and 92.3% for the MIBG test (PD diagnosis). Both tests were useful in differentiating between PD and MSA-P, even in the early stages. In early-stage patients, elevated putaminal ADC was a diagnostic marker for MSA-P. Despite high specificity of the MIBG test, careful neurological history and examinations were required for PD diagnosis because of possible false-negative results.
Lessions learned in WISE image quality
NASA Astrophysics Data System (ADS)
Kendall, Martha; Duval, Valerie G.; Larsen, Mark F.; Heinrichsen, Ingolf H.; Esplin, Roy W.; Shannon, Mark; Wright, Edward L.
2010-08-01
The Wide-Field Infrared Survey Explorer (WISE) mission launched in December of 2009 is a true success story. The mission is performing beyond expectations on-orbit and maintained cost and schedule throughout. How does such a thing happen? A team constantly focused on mission success is a key factor. Mission success is more than a program meeting its ultimate science goals; it is also meeting schedule and cost goals to avoid cancellation. The WISE program can attribute some of its success in achieving the image quality needed to meet science goals to lessons learned along the way. A requirement was missed in early decomposition, the absence of which would have adversely affected end-to-end system image quality. Fortunately, the ability of the cross-organizational team to focus on fixing the problem without pointing fingers or waiting for paperwork was crucial in achieving a timely solution. Asking layman questions early in the program could have revealed requirement flowdown misunderstandings between spacecraft control stability and image processing needs. Such is the lesson learned with the WISE spacecraft Attitude Determination & Control Subsystem (ADCS) jitter control and the image data reductions needs. Spacecraft motion can affect image quality in numerous ways. Something as seemingly benign as different terminology being used by teammates in separate groups working on data reduction, spacecraft ADCS, the instrument, mission operations, and the science proved to be a risk to system image quality. While the spacecraft was meeting the allocated jitter requirement , the drift rate variation need was not being met. This missing need was noticed about a year before launch and with a dedicated team effort, an adjustment was made to the spacecraft ADCS control. WISE is meeting all image quality requirements on-orbit thanks to a diligent team noticing something was missing before it was too late and applying their best effort to find a solution.
Zhan, Yuefu; Liang, Xianwen; Han, Xiangjun; Chen, Jianqiang; Zhang, Shufang; Tan, Shun; Li, Qun; Wang, Xiong; Liu, Fan
2017-02-28
To explore the correlation between the apparent diffusion coefficient (ADC) and mRNA expression of tissue inhibitor of metalloproteinase-1 (TIMP-1) in different stages of liver fibrosis in rats. Methods: A model of liver fibrosis in rats was established by intraperitoneal injection of high-fat diet combined with porcine serum. After drug administration for 4 weeks, 48 rats served as a model group and 12 rats served as a control group, then they underwent diffusion weighted imaging (DWI) scanning. The value of ADC was calculated at b value=800 s/mm2. The rats were sacrificed and carried out pathologic examination after DWI scanning immediately. The mRNA expression of TIMP-1 was detected by real time-polymerase chain reaction (RT-PCR). The rats of hepatic fibrosis were also divided into a S0 group (n=4), a S1 group (n=11), a S2 group (n=12), a S3 group (n=10), and a S4 group (n=9) according to their pathological stage. The value of ADC and the expression of TIMP-1 mRNA among the different stage groups of liver fibrosis were compared, and the correlation between ADC and the TIMP-1 mRNA were analyzed. Results: The ADC value and the TIMP-1 mRNA expression were significantly different between the control group and the liver fibrosis group (F=46.54 and 53.87, P<0.05). There were significant differences in the value of ADC between every two groups (all P<0.05), except the control group vs the S1 group, the S1 group vs the S2 group, and the S2 group vs the S3 group (all P>0.05). For the comparison of TIMP-1 mRNA, there was no significant difference between the S1 group and the S2 group, the S3 group and the S4 group (both P>0.05). There were significant differences among the rest of the groups (all P<0.05). Rank correlation analysis showed that there was a negative correlation between the ADC value and the TIMP-1 mRNA expression (r=-0.76, P<0.01). Conclusion: When the value of ADC decreases in the progress of rats' liver fibrosis, the mRNA expression of TIMP-1 increases gradually, and there is a negative correlation between them.
Rossi, F R; Marina, M; Pieckenstain, F L
2015-07-01
Polyamine biosynthesis starts with putrescine production through the decarboxylation of arginine or ornithine. In Arabidopsis thaliana, putrescine is synthesised exclusively by arginine decarboxylase (ADC), which exists as two isoforms (ADC1 and 2) that are differentially regulated by abiotic stimuli, but their role in defence against pathogens has not been studied in depth. This work analysed the participation of ADC in Arabidopsis defence against Pseudomonas viridiflava. ADC activity and expression, polyamine levels and bacterial resistance were analysed in null mutants of each ADC isoform. In non-infected wild-type (WT) plants, ADC2 expression was much higher than ADC1. Analysis of adc mutants demonstrated that ADC2 contributes to a much higher extent than ADC1 to basal ADC activity and putrescine biosynthesis. In addition, adc2 mutants showed increased basal expression of salicylic acid- and jasmonic acid-dependent PR genes. Bacterial infection induced putrescine accumulation and ADC1 expression in WT plants, but pathogen-induced putrescine accumulation was blocked in adc1 mutants. Results suggest a specific participation of ADC1 in defence, although basal resistance was not decreased by dysfunction of either of the two ADC genes. In addition, and as opposed to WT plants, bacterial infection increased ADC2 expression and ADC activity in adc1 mutants, which could counterbalance the lack of ADC1. Results demonstrate a major contribution of ADC2 to total ADC activity and the specific induction of ADC1 in response to infection. A certain degree of functional redundancy between the two isoforms in relation to their contribution to basal resistance is also evident. © 2015 German Botanical Society and The Royal Botanical Society of the Netherlands.
NASA Technical Reports Server (NTRS)
Kaur-Sawhney, R.; Dai, Y. R.; Galston, A. W.
1986-01-01
When gibberellic acid (GA3) is sprayed on 9-day-old light-brown dwarf Progress pea (Pisum sativum) seedlings, arginine decarboxylase (ADC; EC 4.1.1.9) activity increases within 3 h and peaks at about 9 h after GA3 application. This is followed by a second lower peak at about 30 h; both peaks were higher than the corresponding peaks in the controls. In contrast, no appreciable effect of GA3 on internode length was observed until about 12 h, after which time a dramatic increase in growth rate occurred and persisted for about 12 h. Specific (DL-alpha-difluoromethylarginine) and non-specific (D-arginine and L-canavanine) inhibitors of ADC strongly inhibited ADC activity and to a lesser extent internode growth. The inhibition was reversed only slightly by the addition of polyamines. Actinomycin D and cycloheximide inhibited the rise in ADC activity induced by GA3. The half-life of the enzyme was increased by GA3 treatment. The results suggest that part of the GA3-induced increase in internode growth may result from enhanced polyamine biosynthesis through the ADC pathway. Furthermore, the GA3 induced increase in ADC activity probably requires de novo synthesis of both RNA and protein.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vandecaveye, Vincent, E-mail: Vincent.Vandecaveye@uzleuven.be; Dirix, Piet; De Keyzer, Frederik
2012-03-01
Purpose: To evaluate diffusion-weighted imaging (DWI) for assessment of treatment response in head and neck squamous cell carcinoma (HNSCC) three weeks after the end of chemoradiotherapy (CRT). Methods and Materials: Twenty-nine patients with HNSCC underwent magnetic resonance imaging (MRI) prior to and 3 weeks after CRT, including T{sub 2}-weighted and pre- and postcontrast T{sub 1}-weighted sequences and an echo-planar DWI sequence with six b values (0 to 1,000 s/mm{sup 2}), from which the apparent diffusion coefficient (ADC) was calculated. ADC changes 3 weeks posttreatment compared to baseline ( Increment ADC) between responding and nonresponding primary lesions and adenopathies were correlatedmore » with 2 years locoregional control and compared with a Mann-Whitney test. In a blinded manner, the Increment ADC was compared to conventional MRI 3 weeks post-CRT and the routinely implemented CT, on average 3 months post-CRT, which used size-related and morphological criteria. Positive and negative predictive values (PPV and NPV, respectively) were compared between the Increment ADC and anatomical imaging. Results: The Increment ADC of lesions with later tumor recurrence was significantly lower than lesions with complete remission for both primary lesions (-2.3% {+-} 0.3% vs. 80% {+-} 41%; p < 0.0001) and adenopathies (19.9% {+-} 32% vs. 63% {+-} 36%; p = 0.003). The Increment ADC showed a PPV of 89% and an NPV of 100% for primary lesions and a PPV of 70% and an NPV of 96% for adenopathies per neck side. DWI improved PPV and NPV compared to anatomical imaging. Conclusion: DWI with the Increment ADC 3 weeks after concluding CRT for HNSCC allows for early assessment of treatment response.« less
A multi-channel instrumentation system for biosignal recording.
Yu, Hong; Li, Pengfei; Xiao, Zhiming; Peng, Chung-Ching; Bashirullah, Rizwan
2008-01-01
This paper reports a highly integrated battery operated multi-channel instrumentation system intended for physiological signal recording. The mixed signal IC has been fabricated in standard 0.5microm 5V 3M-2P CMOS process and features 32 instrumentation amplifiers, four 8b SAR ADCs, a wireless power interface with Li-ion battery charger, low power bidirectional telemetry and FSM controller with power gating control for improved energy efficiency. The chip measures 3.2mm by 4.8mm and dissipates approximately 2.1mW when fully operational.
Meyer, Hans-Jonas; Ziemann, Oliver; Kornhuber, Malte; Emmer, Alexander; Quäschling, Ulf; Schob, Stefan; Surov, Alexey
2018-06-01
Background Magnetic resonance imaging (MRI) is widely used in several muscle disorders. Diffusion-weighted imaging (DWI) is an imaging modality, which can reflect microstructural tissue composition. The apparent diffusion coefficient (ADC) is used to quantify the random motion of water molecules in tissue. Purpose To investigate ADC values in patients with myositis and non-inflammatory myopathy and to analyze possible associations between ADC and laboratory parameters in these patients. Material and Methods Overall, 17 patients with several myositis entities, eight patients with non-inflammatory myopathies, and nine patients without muscle disorder as a control group were included in the study (mean age = 55.3 ± 14.3 years). The diagnosis was confirmed by histopathology in every case. DWI was obtained in a 1.5-T scanner using two b-values: 0 and 1000 s/mm 2 . In all patients, the blood sample was acquired within three days to the MRI. The following serological parameters were estimated: C-reactive protein, lactate dehydrogenase, alanine aminotransferase, aspartate aminotransferase, creatine kinase, and myoglobine. Results The estimated mean ADC value for the myositis group was 1.89 ± 0.37 × 10 -3 mm 2 /s and for the non-inflammatory myopathy group was 1.79 ± 0.33 × 10 -3 mm 2 /s, respectively. The mean ADC values (1.15 ± 0.37 × 10 -3 mm 2 /s) were significantly higher to unaffected muscles (vs. myositis P = 0.0002 and vs. myopathy P = 0.0021). There were no significant correlations between serological parameters and ADC values. Conclusion Affected muscles showed statistically significantly higher ADC values than normal muscles. No linear correlations between ADC and serological parameters were identified.
Ma, Teng; Yang, Shaolin; Jing, Haiyan; Cong, Lin; Cao, Zhixin; Liu, Zhiling; Huang, Zhaoqin
2018-03-01
Prostate cancer (PCa) is the second most common cancer in men. The Gleason score (GS) and biomarkers play important roles in the diagnosis and treatment of patients with PCa. The purpose of this study was to investigate the relationship between the apparent diffusion coefficient (ADC) and the molecular markers Ki-67, hypoxia-inducible factor-1α (HIF-1α) and vascular endothelial growth factor (VEGF) in PCa. Thirty-nine patients with 39 lesions, who had been diagnosed with PCa, were enrolled in this study. All patients underwent diffusion-weighted magnetic resonance imaging (DW-MRI) (b = 800 s/mm 2 ). The expression of Ki-67, HIF-1α and VEGF was assessed by immunohistochemistry. Statistical analysis was applied to analyze the association between ADC and prostate-specific antigen (PSA), GS and the expression of Ki-67, HIF-1α and VEGF. The group differences in ADC among different grades of Ki-67, HIF-1α and VEGF were also analyzed. The mean ± standard deviation of ADC was (0.76 ± 0.27) × 10 -3 mm 2 /s. ADC correlated negatively with PSA and GS (p < 0.05). The Ki-67 staining index (SI), HIF-1α expression and VEGF expression in PCa were correlated inversely with ADC, controlling for age (r = -0.332, p < 0.05; r = -0.662, p < 0.0005; and r = -0.714, p < 0.0005, respectively). ADC showed a significant difference among different grades of Ki-67 (F = 9.164, p = 0.005), HIF-1α (F = 40.333, p < 0.0005) and VEGF (F = 22.048, p < 0.0005). In conclusion, ADC was correlated with PSA, GS, and Ki-67, HIF-1α and VEGF expression in patients with PCa. ADC may be used to evaluate tumor proliferation, hypoxia and angiogenesis in PCa. Copyright © 2018 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Taliercio, C.; Luchetta, A.; Manduchi, G.; Rigoni, A.
2017-07-01
High-speed event driven acquisition is normally performed by analog-to-digital converter (ADC) boards with a given number of pretrigger sample and posttrigger sample that are recorded upon the occurrence of a hardware trigger. A direct physical connection is, therefore, required between the source of event (trigger) and the ADC, because any other software-based communication method would introduce a delay in triggering that would turn out to be not acceptable in many cases. This paper proposes a solution for the relaxation of the event communication time that can be, in this case, carried out by software messaging (e.g., via an LAN), provided that the system components are synchronized in time using the IEEE 1588 synchronization mechanism. The information about the exact event occurrence time is contained in the software packet that is sent to communicate the event and is used by the ADC FPGA to identify the exact sample in the ADC sample queue. The length of the ADC sample queue will depend on the maximum delay in software event message communication time. A prototype implementation using a National FlexRIO FPGA board connected with an ADC device is presented as the proof of concept.
Pepe, Pietro; D'Urso, Davide; Garufi, Antonio; Priolo, Giandomenico; Pennisi, Michele; Russo, Giorgio; Sabini, Maria Gabriella; Valastro, Lucia Maria; Galia, Antonio; Fraggetta, Filippo
2017-01-01
To evaluate the accuracy of multiparametric magnetic resonance imaging apparent diffusion coefficient (mpMRI ADC) in the diagnosis of clinically significant prostate cancer (PCa). From January 2016 to December 2016, 44 patients who underwent radical prostatectomy for PCa and mpMRI lesions suggestive of cancer were retrospectively evaluated at definitive specimen. The accuracy of suspicious mpMRI prostate imaging reporting and data system (PI-RADS ≥3) vs. ADC values in the diagnosis of Gleason score ≥7 was evaluated. Receiver operating characteristics (ROC) curve analysis gave back an ADC threshold of 0.747×10 -3 mm 2 /s to separate between Gleason Score 6 and ≥7. The diagnostic accuracy of ADC value (cut-off 0.747×10 -3 mm 2 /s) vs. PI-RADS score ≥3 in diagnosing PCa with Gleason score ≥7 was equal to 84% vs. 63.6% with an area under the curve (AUC) ROC of 0.81 vs. 0.71, respectively. ADC evaluation could support clinicians in decision making of patients with PI-RADS score <3 at risk for PCa. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
Wang, Qian; Zhao, Yingyuan; Guan, Lei; Zhang, Yaping; Dang, Qifeng; Dong, Ping; Li, Jing; Liang, Xingguo
2017-07-15
DNA/chitosan co-assemblies were initially used as nanocarriers for efficient astaxanthin encapsulation and delivery. The obtained astaxanthin-loaded DNA/chitosan (ADC) colloidal system was transparent and homogenous, with astaxanthin content up to 65μg/ml. Compared to free astaxanthin, ADC nanoparticles with an astaxanthin concentration as low as 3.35nM still showed a more powerful cytoprotective effect on H 2 O 2 -induced oxidative cell damage, and improved cell viability from 49.9% to 61.9%. The ROS scavenging efficiency of ADC nanoparticles was as high as 54.3%, which was 2-fold higher than that of free astaxanthin. Besides this, ADC nanoparticles were easily engulfed by Caco-2 cells in a short time, indicating that the encapsulated astaxanthin could be absorbed through endocytosis by intestinal epithelial cells. The improved antioxidation capability and facilitated cellular uptake enabled the ADC nanoparticles to be good candidates for efficient delivery and absorption of astaxanthin. Copyright © 2017 Elsevier Ltd. All rights reserved.
Development of multichannel analyzer using sound card ADC for nuclear spectroscopy system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ibrahim, Maslina Mohd; Yussup, Nolida; Lombigit, Lojius
This paper describes the development of Multi-Channel Analyzer (MCA) using sound card analogue to digital converter (ADC) for nuclear spectroscopy system. The system was divided into a hardware module and a software module. Hardware module consist of detector NaI (Tl) 2” by 2”, Pulse Shaping Amplifier (PSA) and a build in ADC chip from readily available in any computers’ sound system. The software module is divided into two parts which are a pre-processing of raw digital input and the development of the MCA software. Band-pass filter and baseline stabilization and correction were implemented for the pre-processing. For the MCA development,more » the pulse height analysis method was used to process the signal before displaying it using histogram technique. The development and tested result for using the sound card as an MCA are discussed.« less
Pseudo Asynchronous Level Crossing adc for ecg Signal Acquisition.
Marisa, T; Niederhauser, T; Haeberlin, A; Wildhaber, R A; Vogel, R; Goette, J; Jacomet, M
2017-02-07
A new pseudo asynchronous level crossing analogue-to-digital converter (adc) architecture targeted for low-power, implantable, long-term biomedical sensing applications is presented. In contrast to most of the existing asynchronous level crossing adc designs, the proposed design has no digital-to-analogue converter (dac) and no continuous time comparators. Instead, the proposed architecture uses an analogue memory cell and dynamic comparators. The architecture retains the signal activity dependent sampling operation by generating events only when the input signal is changing. The architecture offers the advantages of smaller chip area, energy saving and fewer analogue system components. Beside lower energy consumption the use of dynamic comparators results in a more robust performance in noise conditions. Moreover, dynamic comparators make interfacing the asynchronous level crossing system to synchronous processing blocks simpler. The proposed adc was implemented in [Formula: see text] complementary metal-oxide-semiconductor (cmos) technology, the hardware occupies a chip area of 0.0372 mm 2 and operates from a supply voltage of [Formula: see text] to [Formula: see text]. The adc's power consumption is as low as 0.6 μW with signal bandwidth from [Formula: see text] to [Formula: see text] and achieves an equivalent number of bits (enob) of up to 8 bits.
Tsili, Athina C; Ntorkou, Alexandra; Astrakas, Loukas; Xydis, Vasilis; Tsampalas, Stavros; Sofikitis, Nikolaos; Argyropoulou, Maria I
2017-04-01
To evaluate the difference in apparent diffusion coefficient (ADC) measurements at diffusion-weighted (DW) magnetic resonance imaging of differently shaped regions-of-interest (ROIs) in testicular germ cell neoplasms (TGCNS), the diagnostic ability of differently shaped ROIs in differentiating seminomas from nonseminomatous germ cell neoplasms (NSGCNs) and the interobserver variability. Thirty-three TGCNs were retrospectively evaluated. Patients underwent MR examinations, including DWI on a 1.5-T MR system. Two observers measured mean tumor ADCs using four distinct ROI methods: round, square, freehand and multiple small, round ROIs. The interclass correlation coefficient was analyzed to assess interobserver variability. Statistical analysis was used to compare mean ADC measurements among observers, methods and histologic types. All ROI methods showed excellent interobserver agreement, with excellent correlation (P<0.001). Multiple, small ROIs provided the lower mean ADC in TGCNs. Seminomas had lower mean ADC compared to NSGCNs for each ROI method (P<0.001). Round ROI proved the most accurate method in characterizing TGCNS. Interobserver variability in ADC measurement is excellent, irrespective of the ROI shape. Multiple, small round ROIs and round ROI proved the more accurate methods for ADC measurement in the characterization of TGCNs and in the differentiation between seminomas and NSGCNs, respectively. Copyright © 2017 Elsevier B.V. All rights reserved.
Designed cell consortia as fragrance-programmable analog-to-digital converters.
Müller, Marius; Ausländer, Simon; Spinnler, Andrea; Ausländer, David; Sikorski, Julian; Folcher, Marc; Fussenegger, Martin
2017-03-01
Synthetic biology advances the rational engineering of mammalian cells to achieve cell-based therapy goals. Synthetic gene networks have nearly reached the complexity of digital electronic circuits and enable single cells to perform programmable arithmetic calculations or to provide dynamic remote control of transgenes through electromagnetic waves. We designed a synthetic multilayered gaseous-fragrance-programmable analog-to-digital converter (ADC) allowing for remote control of digital gene expression with 2-bit AND-, OR- and NOR-gate logic in synchronized cell consortia. The ADC consists of multiple sampling-and-quantization modules sensing analog gaseous fragrance inputs; a gas-to-liquid transducer converting fragrance intensity into diffusible cell-to-cell signaling compounds; a digitization unit with a genetic amplifier circuit to improve the signal-to-noise ratio; and recombinase-based digital expression switches enabling 2-bit processing of logic gates. Synthetic ADCs that can remotely control cellular activities with digital precision may enable the development of novel biosensors and may provide bioelectronic interfaces synchronizing analog metabolic pathways with digital electronics.
Fuzzy attitude control for a nanosatellite in leo orbit
NASA Astrophysics Data System (ADS)
Calvo, Daniel; Laverón-Simavilla, Ana; Lapuerta, Victoria; Aviles, Taisir
Fuzzy logic controllers are flexible and simple, suitable for small satellites Attitude Determination and Control Subsystems (ADCS). In this work, a tailored fuzzy controller is designed for a nanosatellite and is compared with a traditional Proportional Integrative Derivative (PID) controller. Both control methodologies are compared within the same specific mission. The orbit height varies along the mission from injection at around 380 km down to a 200 km height orbit, and the mission requires pointing accuracy over the whole time. Due to both the requirements imposed by such a low orbit, and the limitations in the power available for the attitude control, a robust and efficient ADCS is required. For these reasons a fuzzy logic controller is implemented as the brain of the ADCS and its performance and efficiency are compared to a traditional PID. The fuzzy controller is designed in three separated controllers, each one acting on one of the Euler angles of the satellite in an orbital frame. The fuzzy memberships are constructed taking into account the mission requirements, the physical properties of the satellite and the expected performances. Both methodologies, fuzzy and PID, are fine-tuned using an automated procedure to grant maximum efficiency with fixed performances. Finally both methods are probed in different environments to test their characteristics. The simulations show that the fuzzy controller is much more efficient (up to 65% less power required) in single maneuvers, achieving similar, or even better, precision than the PID. The accuracy and efficiency improvement of the fuzzy controller increase with orbit height because the environmental disturbances decrease, approaching the ideal scenario. A brief mission description is depicted as well as the design process of both ADCS controllers. Finally the validation process and the results obtained during the simulations are described. Those results show that the fuzzy logic methodology is valid for small satellites' missions benefiting from a well-developed artificial intelligence theory.
Xu, Xiao-Quan; Li, Yan; Hong, Xun-Ning; Wu, Fei-Yun; Shi, Hai-Bin
2017-02-01
To assess the role of whole-tumor histogram analysis of apparent diffusion coefficient (ADC) maps in differentiating radiological indeterminate vestibular schwannoma (VS) from meningioma in cerebellopontine angle (CPA). Diffusion-weighted (DW) images (b = 0 and 1000 s/mm 2 ) of pathologically confirmed and radiological indeterminate CPA meningioma (CPAM) (n = 27) and VS (n = 12) were retrospectively collected and processed with mono-exponential model. Whole-tumor regions of interest were drawn on all slices of the ADC maps to obtain histogram parameters, including the mean ADC (ADC mean ), median ADC (ADC median ), 10th/25th/75th/90th percentile ADC (ADC 10 , ADC 25 , ADC 75 and ADC 90 ), skewness and kurtosis. The differences of ADC histogram parameters between CPAM and VS were compared using unpaired t-test. Multiple receiver operating characteristic (ROC) curves analysis was used to determine and compare the diagnostic value of each significant parameter. Significant differences were found on the ADC mean , ADC median , ADC 10 , ADC 25 , ADC 75 and ADC 90 between CPAM and VS (all p values < 0.001), while no significant difference was found on kurtosis (p = 0.562) and skewness (p = 0.047). ROC curves analysis revealed, a cut-off value of 1.126 × 10 -3 mm 2 /s for the ADC 90 value generated highest area under curves (AUC) for differentiating CPAM from VS (AUC, 0.975; sensitivity, 100%; specificity, 88.9%). Histogram analysis of ADC maps based on whole tumor can be a useful tool for differentiating radiological indeterminate CPAM from VS. The ADC 90 value was the most promising parameter for differentiating these two entities.
Abuhandan, M; Cece, H; Calik, M; Karakas, E; Dogan, F; Karakas, O
2013-03-01
This study aimed to evaluate the contribution of diffusion weighted magnetic resonance imaging to the diagnosis and staging of subacute sclerosing panencephalitis. The study comprised 26 patients diagnosed with subacute sclerosing panencephalitis at our clinic who were undergoing regular follow-up, and a control group of 18 subjects. Clinical staging was determined by Risk and Haddad classification; 12 at Stage II and 14 at Stage III. Diffusion weighted magnetic resonance images were taken of six areas (frontal, parieto-occipital, cerebellar, deep white matter, thalamus and basal ganglia) and by calculating the apparent diffusion coefficient (ADC) values, and a comparison was made between the stages and with the control group. The ADC values of all the areas of the subacute sclerosing panencephalitis patients were found to be significantly higher compared to the control group (p < 0.05). While the mean ADC values of the deep white matter, basal ganglia, frontal and parieto-occipital areas of the Stage II patients were found to be significant compared to the control group (p < 0.05), there was no significance in the other areas (p > 0.05). The ADC values of all the areas of the Stage III patients were found to be significantly high compared to the Stage II values (p < 0.05). Diffusion weighted magnetic resonance imaging can be used with other diagnostic criteria to confirm diagnosis of subacute sclerosing panencephalitis and to reveal differences between the stages.
Auto Code Generation for Simulink-Based Attitude Determination Control System
NASA Technical Reports Server (NTRS)
MolinaFraticelli, Jose Carlos
2012-01-01
This paper details the work done to auto generate C code from a Simulink-Based Attitude Determination Control System (ADCS) to be used in target platforms. NASA Marshall Engineers have developed an ADCS Simulink simulation to be used as a component for the flight software of a satellite. This generated code can be used for carrying out Hardware in the loop testing of components for a satellite in a convenient manner with easily tunable parameters. Due to the nature of the embedded hardware components such as microcontrollers, this simulation code cannot be used directly, as it is, on the target platform and must first be converted into C code; this process is known as auto code generation. In order to generate C code from this simulation; it must be modified to follow specific standards set in place by the auto code generation process. Some of these modifications include changing certain simulation models into their atomic representations which can bring new complications into the simulation. The execution order of these models can change based on these modifications. Great care must be taken in order to maintain a working simulation that can also be used for auto code generation. After modifying the ADCS simulation for the auto code generation process, it is shown that the difference between the output data of the former and that of the latter is between acceptable bounds. Thus, it can be said that the process is a success since all the output requirements are met. Based on these results, it can be argued that this generated C code can be effectively used by any desired platform as long as it follows the specific memory requirements established in the Simulink Model.
Receiver System Analysis and Optimization
2013-01-01
designers to make best use of advanced silicon processes (scale, fast devices) while minimizing the disadvantages (low-Q passives, low transimpedance ). A...components such as amplifiers , filters, mixers, oscillators, etc. Specifications for the components are then passed on to design teams. The digital and...cascade connection of an LNA, Mixer, Voltage Controlled Oscillator [VCO], Amplifier and Analog to Digital Converter [ADC] as well as appropriate
Length of intact plasma membrane determines the diffusion properties of cellular water
Eida, Sato; Van Cauteren, Marc; Hotokezaka, Yuka; Katayama, Ikuo; Sasaki, Miho; Obara, Makoto; Okuaki, Tomoyuki; Sumi, Misa; Nakamura, Takashi
2016-01-01
Molecular diffusion in a boundary-free medium depends only on the molecular size, the temperature, and medium viscosity. However, the critical determinant of the molecular diffusion property in inhomogeneous biological tissues has not been identified. Here, using an in vitro system and a high-resolution MR imaging technique, we show that the length of the intact plasma membrane is a major determinant of water diffusion in a controlled cellular environment and that the cell perimeter length (CPL) is sufficient to estimate the apparent diffusion coefficient (ADC) of water in any cellular environment in our experimental system (ADC = −0.21 × CPL + 1.10). We used this finding to further explain the different diffusion kinetics of cells that are dying via apoptotic or non-apoptotic cell death pathways exhibiting characteristic changes in size, nuclear and cytoplasmic architectures, and membrane integrity. These results suggest that the ADC value can be used as a potential biomarker for cell death. PMID:26750342
NASA Technical Reports Server (NTRS)
Hodges, Richard E.; Sands, O. Scott; Huang, John; Bassily, Samir
2006-01-01
Improved surface accuracy for deployable reflectors has brought with it the possibility of Ka-band reflector antennas with extents on the order of 1000 wavelengths. Such antennas are being considered for high-rate data delivery from planetary distances. To maintain losses at reasonable levels requires a sufficiently capable Attitude Determination and Control System (ADCS) onboard the spacecraft. This paper provides an assessment of currently available ADCS strategies and performance levels. In addition to other issues, specific factors considered include: (1) use of "beaconless" or open loop tracking versus use of a beacon on the Earth side of the link, and (2) selection of fine pointing strategy (body-fixed/spacecraft pointing, reflector pointing or various forms of electronic beam steering). Capabilities of recent spacecraft are discussed.
Anderson, Stephan W; Jara, Hernan; Ozonoff, Al; O'Brien, Michael; Hamilton, James A; Soto, Jorge A
2012-01-01
To evaluate the effects of hepatic fibrosis on ADC and T(2) values of ex vivo murine liver specimens imaged using 11.7 Tesla (T) MRI. This animal study was IACUC approved. Seventeen male, C57BL/6 mice were divided into control (n = 2) and experimental groups (n = 15), the latter fed a 3, 5-dicarbethoxy-1, 4-dihydrocollidine (DDC) supplemented diet, inducing hepatic fibrosis. Ex vivo liver specimens were imaged using an 11.7T MRI scanner. Spin-echo pulsed field gradient and multi-echo spin-echo acquisitions were used to generate parametric ADC and T(2) maps, respectively. Degrees of fibrosis were determined by the evaluation of a pathologist as well as digital image analysis. Scatterplot graphs comparing ADC and T(2) to degrees of fibrosis were generated and correlation coefficients were calculated. Strong correlation was found between degrees of hepatic fibrosis and ADC with higher degrees of fibrosis associated with lower hepatic ADC values. Moderate correlation between hepatic fibrosis and T(2) values was seen with higher degrees of fibrosis associated with lower T(2) values. Inverse relationships between degrees of fibrosis and both ADC and T(2) are seen, highlighting the utility of these parameters in the ongoing development of an MRI methodology to quantify hepatic fibrosis. Copyright © 2011 Wiley Periodicals, Inc.
Kong, Ling-Yan; Zhang, Wei; Zhou, Yue; Xu, Hai; Shi, Hai-Bin; Feng, Qing; Xu, Xiao-Quan; Yu, Tong-Fu
2018-04-01
To investigate the value of apparent diffusion coefficients (ADCs) histogram analysis for assessing World Health Organization (WHO) pathological classification and Masaoka clinical stages of thymic epithelial tumours. 37 patients with histologically confirmed thymic epithelial tumours were enrolled. ADC measurements were performed using hot-spot ROI (ADC HS-ROI ) and histogram-based approach. ADC histogram parameters included mean ADC (ADC mean ), median ADC (ADC median ), 10 and 90 percentile of ADC (ADC 10 and ADC 90 ), kurtosis and skewness. One-way ANOVA, independent-sample t-test, and receiver operating characteristic were used for statistical analyses. There were significant differences in ADC mean , ADC median , ADC 10 , ADC 90 and ADC HS-ROI among low-risk thymoma (type A, AB, B1; n = 14), high-risk thymoma (type B2, B3; n = 9) and thymic carcinoma (type C, n = 14) groups (all p-values <0.05), while no significant difference in skewness (p = 0.181) and kurtosis (p = 0.088). ADC 10 showed best differentiating ability (cut-off value, ≤0.689 × 10 -3 mm 2 s -1 ; AUC, 0.957; sensitivity, 95.65%; specificity, 92.86%) for discriminating low-risk thymoma from high-risk thymoma and thymic carcinoma. Advanced Masaoka stages (Stage III and IV; n = 24) tumours showed significant lower ADC parameters and higher kurtosis than early Masaoka stage (Stage I and II; n = 13) tumours (all p-values <0.05), while no significant difference on skewness (p = 0.063). ADC 10 showed best differentiating ability (cut-off value, ≤0.689 × 10 -3 mm 2 s -1 ; AUC, 0.913; sensitivity, 91.30%; specificity, 85.71%) for discriminating advanced and early Masaoka stage epithelial tumours. ADC histogram analysis may assist in assessing the WHO pathological classification and Masaoka clinical stages of thymic epithelial tumours. Advances in knowledge: 1. ADC histogram analysis could help to assess WHO pathological classification of thymic epithelial tumours. 2. ADC histogram analysis could help to evaluate Masaoka clinical stages of thymic epithelial tumours. 3. ADC 10 might be a promising imaging biomarker for assessing and characterizing thymic epithelial tumours.
Qin, Lei; Li, Angie; Qu, Jinrong; Reinshagen, Katherine; Li, Xiang; Cheng, Su-Chun; Bryant, Annie; Young, Geoffrey S
2018-04-01
Mixed reports leave uncertainty about whether normalization of apparent diffusion coefficient (ADC) to a within-subject white matter reference is necessary for assessment of tumor cellularity. We tested whether normalization improves the previously reported correlation of resection margin ADC with 15-month overall survival (OS) in HGG patients. Spin-echo echo-planar DWI was retrieved from 3 T MRI acquired between maximal resection and radiation in 37 adults with new-onset HGG (25 glioblastoma; 12 anaplastic astrocytoma). ADC maps were produced with the FSL DTIFIT tool (Oxford Centre for Functional MRI). 3 neuroradiologists manually selected regions of interest (ROI) in normal appearing white matter (NAWM) and in non-enhancing tumor (NT) < 2 cm from the margin of residual enhancing tumor or resection cavity. Normalized ADC (nADC) was computed as the ratio of absolute NT ADC to NAWM ADC. Reproducibility of nADC and absolute ADC among the readers' ROI was assessed using intra-class correlation coefficient (ICC) and within-subject coefficient of variation (wCV). Correlations of ADC and nADC with OS were compared using receiver operating characteristics (ROC) analysis. A p value 0.05 was considered statistically significant. Both mean ADC and nADC differed significantly between patients subgrouped by 15-month OS (p = 0.0014 and 0.0073 respectively). wCV and ICC among the readers were similar for absolute and normalized ADC. In ROC analysis of correlation with OS, nADC did not perform significantly better than absolute ADC. Normalization does not significantly improve the correlation of absolute ADC with OS in HGG, suggesting that normalization is not necessary for clinical or research ADC analysis in HGG patients.
Srinivasan, A; Galbán, C J; Johnson, T D; Chenevert, T L; Ross, B D; Mukherji, S K
2010-04-01
Does the K-means algorithm do a better job of differentiating benign and malignant neck pathologies compared to only mean ADC? The objective of our study was to analyze the differences between ADC partitions to evaluate whether the K-means technique can be of additional benefit to whole-lesion mean ADC alone in distinguishing benign and malignant neck pathologies. MR imaging studies of 10 benign and 10 malignant proved neck pathologies were postprocessed on a PC by using in-house software developed in Matlab. Two neuroradiologists manually contoured the lesions, with the ADC values within each lesion clustered into 2 (low, ADC-ADC(L); high, ADC-ADC(H)) and 3 partitions (ADC(L); intermediate, ADC-ADC(I); ADC(H)) by using the K-means clustering algorithm. An unpaired 2-tailed Student t test was performed for all metrics to determine statistical differences in the means of the benign and malignant pathologies. A statistically significant difference between the mean ADC(L) clusters in benign and malignant pathologies was seen in the 3-cluster models of both readers (P = .03 and .022, respectively) and the 2-cluster model of reader 2 (P = .04), with the other metrics (ADC(H), ADC(I); whole-lesion mean ADC) not revealing any significant differences. ROC curves demonstrated the quantitative differences in mean ADC(H) and ADC(L) in both the 2- and 3-cluster models to be predictive of malignancy (2 clusters: P = .008, area under curve = 0.850; 3 clusters: P = .01, area under curve = 0.825). The K-means clustering algorithm that generates partitions of large datasets may provide a better characterization of neck pathologies and may be of additional benefit in distinguishing benign and malignant neck pathologies compared with whole-lesion mean ADC alone.
NASA Technical Reports Server (NTRS)
Kimnach, Greg L.; Lebron, Ramon C.; Fox, David A.
1999-01-01
The John H. Glenn Research Center at Lewis Field (GRC) in Cleveland, OH and the Sundstrand Corporation in Rockford, IL have designed and developed an Engineering Model (EM) Electrical Power Control Unit (EPCU) for the Fluids Combustion Facility, (FCF) experiments to be flown on the International Space Station (ISS). The EPCU will be used as the power interface to the ISS power distribution system for the FCF's space experiments'test and telemetry hardware. Furthermore. it is proposed to be the common power interface for all experiments. The EPCU is a three kilowatt 12OVdc-to-28Vdc converter utilizing three independent Power Converter Units (PCUs), each rated at 1kWe (36Adc @ 28Vdc) which are paralleled and synchronized. Each converter may be fed from one of two ISS power channels. The 28Vdc loads are connected to the EPCU output via 48 solid-state and current-limiting switches, rated at 4Adc each. These switches may be paralleled to supply any given load up to the 108Adc normal operational limit of the paralleled converters. The EPCU was designed in this manner to maximize allocated-power utilization. to shed loads autonomously, to provide fault tolerance. and to provide a flexible power converter and control module to meet various ISS load demands. Tests of the EPCU in the Power Systems Facility testbed at GRC reveal that the overall converted-power efficiency, is approximately 89% with a nominal-input voltage of 12OVdc and a total load in the range of 4O% to 110% rated 28Vdc load. (The PCUs alone have an efficiency of approximately 94.5%). Furthermore, the EM unit passed all flight-qualification level (and beyond) vibration tests, passed ISS EMI (conducted, radiated. and susceptibility) requirements. successfully operated for extended periods in a thermal/vacuum chamber, was integrated with a proto-flight experiment and passed all stability and functional requirements.
NASA Astrophysics Data System (ADS)
Villa, Carlos; Kumavor, Patrick; Donkor, Eric
2008-04-01
Photonics Analog-to-Digital Converters (ADCs) utilize a train of optical pulses to sample an electrical input waveform applied to an electrooptic modulator or a reverse biased photodiode. In the former, the resulting train of amplitude-modulated optical pulses is detected (converter to electrical) and quantized using a conversional electronics ADC- as at present there are no practical, cost-effective optical quantizers available with performance that rival electronic quantizers. In the latter, the electrical samples are directly quantized by the electronics ADC. In both cases however, the sampling rate is limited by the speed with which the electronics ADC can quantize the electrical samples. One way to increase the sampling rate by a factor N is by using the time-interleaved technique which consists of a parallel array of N electrical ADC converters, which have the same sampling rate but different sampling phase. Each operating at a quantization rate of fs/N where fs is the aggregated sampling rate. In a system with no real-time operation, the N channels digital outputs are stored in memory, and then aggregated (multiplexed) to obtain the digital representation of the analog input waveform. Alternatively, for real-time operation systems the reduction of storing time in the multiplexing process is desired to improve the time response of the ADC. The complete elimination of memories come expenses of concurrent timing and synchronization in the aggregation of the digital signal that became critical for a good digital representation of the analog signal waveform. In this paper we propose and demonstrate a novel optically synchronized encoder and multiplexer scheme for interleaved photonics ADCs that utilize the N optical signals used to sample different phases of an analog input signal to synchronize the multiplexing of the resulting N digital output channels in a single digital output port. As a proof of concept, four 320 Megasamples/sec 12-bit of resolution digital signals were multiplexed to form an aggregated 1.28 Gigasamples/sec single digital output signal.
Surov, Alexey; Hamerla, Gordian; Meyer, Hans Jonas; Winter, Karsten; Schob, Stefan; Fiedler, Eckhard
2018-09-01
To analyze several histopathological features and their possible correlations with whole lesion histogram analysis derived from ADC maps in meningioma. The retrospective study involved 36 patients with primary meningiomas. For every tumor, the following histogram analysis parameters of apparent diffusion coefficient (ADC) were calculated: ADC mean , ADC max , ADC min , ADC median , ADC mode , ADC percentiles: P10, P25, P75, P90, as well kurtosis, skewness, and entropy. All measures were performed by two radiologists. Proliferation index KI 67, minimal, maximal and mean cell count, total nucleic area, and expression of water channel aquaporin 4 (AQP4) were estimated. Spearman's correlation coefficient was used to analyze associations between investigated parameters. A perfect interobserver agreement for all ADC values (0.84-0.97) was identified. All ADC values correlated inversely with tumor cellularity with the strongest correlation between P10, P25 and mean cell count (-0.558). KI 67 correlated inversely with all ADC values except ADC min . ADC parameters did not correlate with total nucleic area. All ADC values correlated statistically significant with expression of AQP4. ADC histogram analysis is a valid method with an excellent interobserver agreement. Cellularity parameters and proliferation potential are associated with different ADC values. Membrane permeability may play a greater role for water diffusion than cell count and proliferation activity. Copyright © 2018 Elsevier Inc. All rights reserved.
Implementation of integrated circuit and design of SAR ADC for fully implantable hearing aids.
Kim, Jong Hoon; Lee, Jyung Hyun; Cho, Jin-Ho
2017-07-20
The hearing impaired population has been increasing; many people suffer from hearing problems. To deal with this difficulty, various types of hearing aids are being rapidly developed. In particular, fully implantable hearing aids are being actively studied to improve the performance of existing hearing aids and to reduce the stigma of hearing loss patients. It has to be of small size and low-power consumption for easy implantation and long-term use. The objective of the study was to implement a small size and low-power consumption successive approximation register analog-to-digital converter (SAR ADC) for fully implantable hearing aids. The ADC was selected as the SAR ADC because its analog circuit components are less required by the feedback circuit of the SAR ADC than the sigma-delta ADC which is conventionally used in hearing aids, and it has advantages in the area and power consumption. So, the circuit of SAR ADC is designed considering the speech region of humans because the objective is to deliver the speech signals of humans to hearing loss patients. If the switch of sample and hold works in the on/off positions, the charge injection and clock feedthrough are produced by a parasitic capacitor. These problems affect the linearity of the hold voltage, and as a result, an error of the bit conversion is generated. In order to solve the problem, a CMOS switch that consists of NMOS and PMOS was used, and it reduces the charge injection because the charge carriers in the NMOS and PMOS have inversed polarity. So, 16 bit conversion is performed before the occurrence of the Least Significant Bit (LSB) error. In order to minimize the offset voltage and power consumption of the designed comparator, we designed a preamplifier with current mirror. Therefore, the power consumption was reduced by the power control switch used in the comparator. The layout of the designed SAR ADC was performed by Virtuoso Layout Editor (Cadence, USA). In the layout result, the size of the designed SAR ADC occupied 124.9 μm × 152.1 μm. The circuit verification was performed by layout versus schematic (LVS) and design rule check (DRC) which are provided by Calibre (Mentor Graphics, USA), and it was confirmed that there was no error. The designed SAR ADC was implemented in SMIC 180 nm CMOS technology. The operation of the manufactured SAR ADC was confirmed by using an oscilloscope. The SAR ADC output was measured using a distortion meter (HM 8027), when applying pure tone sounds of 94 dB SPL at 500, 800, and 1600 Hz regions. As a result, the THD performance of the proposed chip was satisfied with the ANSI. s3. 22. 2003 standard. We proposed a low-power 16-bit 32 kHz SAR ADC for fully implantable hearing aids. The manufactured SAR ADC based on this design was confirmed to have advantages in power consumption and size through the comparison with the conventional ADC. Therefore, the manufactured SAR ADC is expected to be used in the implantable medical device field and speech signal processing field, which require small size and low power consumption.
Neuronal loss is an early component of subacute sclerosing panencephalitis.
Yüksel, Deniz; Diren, Barış; Ulubay, Hakan; Altunbaşak, Sakir; Anlar, Banu
2014-09-02
We performed diffusion tensor imaging (DTI) and magnetic resonance spectroscopy (MRS) studies in a group of patients with subacute sclerosing panencephalitis (SSPE) in order to estimate the pathologic process underlying the phenotypic variability. Patients with SSPE who had MRI including DTI and MRS examinations were evaluated according to their clinical status as determined by the SSPE Scoring System and their mental age as determined by tests appropriate for age and developmental level. Comparisons of fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values and metabolite ratios of frontal periventricular white matter, parieto-occipital periventricular white matter, and globus pallidus in both hemispheres were made between control and SSPE groups, and between SSPE subgroups. Control (n = 18) and SSPE (n = 39) groups differed in all DTI and MRS parameters except FA, choline (Cho), and Cho/creatine (Cr). SSPE cases had higher ADC and lower N-acetylaspartate (NAA), NAA/Cho, and NAA/Cr in all regions of interest, suggesting cell loss. Disease progression rate and neurologic deficit appeared to be associated with the degree of ADC elevation and NAA reduction: the group with severe global deterioration had the lowest NAA (230.75 ± 197.97 in forceps minor), and rapid progression was associated with acute reduction in NAA. The combination of MRS and diffusion MRI findings suggests neuronal loss can be a primary target in rapidly or subacutely progressing SSPE, and preservation or regeneration of axonal structure may be beneficial in chronic cases. © 2014 American Academy of Neurology.
Nakajima, Erica C; Frankland, Michael P; Johnson, Tucker F; Antic, Sanja L; Chen, Heidi; Chen, Sheau-Chiann; Karwoski, Ronald A; Walker, Ronald; Landman, Bennett A; Clay, Ryan D; Bartholmai, Brian J; Rajagopalan, Srinivasan; Peikert, Tobias; Massion, Pierre P; Maldonado, Fabien
2018-01-01
Lung adenocarcinoma (ADC), the most common lung cancer type, is recognized increasingly as a disease spectrum. To guide individualized patient care, a non-invasive means of distinguishing indolent from aggressive ADC subtypes is needed urgently. Computer-Aided Nodule Assessment and Risk Yield (CANARY) is a novel computed tomography (CT) tool that characterizes early ADCs by detecting nine distinct CT voxel classes, representing a spectrum of lepidic to invasive growth, within an ADC. CANARY characterization has been shown to correlate with ADC histology and patient outcomes. This study evaluated the inter-observer variability of CANARY analysis. Three novice observers segmented and analyzed independently 95 biopsy-confirmed lung ADCs from Vanderbilt University Medical Center/Nashville Veterans Administration Tennessee Valley Healthcare system (VUMC/TVHS) and the Mayo Clinic (Mayo). Inter-observer variability was measured using intra-class correlation coefficient (ICC). The average ICC for all CANARY classes was 0.828 (95% CI 0.76, 0.895) for the VUMC/TVHS cohort, and 0.852 (95% CI 0.804, 0.901) for the Mayo cohort. The most invasive voxel classes had the highest ICC values. To determine whether nodule size influenced inter-observer variability, an additional cohort of 49 sub-centimeter nodules from Mayo were also segmented by three observers, with similar ICC results. Our study demonstrates that CANARY ADC classification between novice CANARY users has an acceptably low degree of variability, and supports the further development of CANARY for clinical application.
78 FR 1735 - Airworthiness Directives; Honeywell International Inc. Air Data Pressure Transducers
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-09
... reviewed Honeywell Alert Service Bulletin ADM/ADC/ADAHRS-34-A01, dated November 6, 2012. This service...), air data computers, air data attitude heading reference systems, and digital air data computers... fails. Honeywell Service Bulletin ACM/ADC/ADAHRS-34-A01, dated November 6, 2012, specifies to refer to...
A comparison of automated dispensing cabinet optimization methods.
O'Neil, Daniel P; Miller, Adam; Cronin, Daniel; Hatfield, Chad J
2016-07-01
Results of a study comparing two methods of optimizing automated dispensing cabinets (ADCs) are reported. Eight nonprofiled ADCs were optimized over six months. Optimization of each cabinet involved three steps: (1) removal of medications that had not been dispensed for at least 180 days, (2) movement of ADC stock to better suit end-user needs and available space, and (3) adjustment of par levels (desired on-hand inventory levels). The par levels of four ADCs (the Day Supply group) were adjusted according to average daily usage; the par levels of the other four ADCs (the Formula group) were adjusted using a standard inventory formula. The primary outcome was the vend:fill ratio, while secondary outcomes included total inventory, inventory cost, quantity of expired medications, and ADC stockout percentage. The total number of medications stocked in the eight machines was reduced from 1,273 in a designated two-month preoptimization period to 1,182 in a designated two-month postoptimization period, yielding a carrying cost savings of $44,981. The mean vend:fill ratios before and after optimization were 4.43 and 4.46, respectively. The vend:fill ratio for ADCs in the Formula group increased from 4.33 before optimization to 5.2 after optimization; in the Day Supply group, the ratio declined (from 4.52 to 3.90). The postoptimization interaction difference between the Formula and Day Supply groups was found to be significant (p = 0.0477). ADC optimization via a standard inventory formula had a positive impact on inventory costs, refills, vend:fill ratios, and stockout percentages. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Nougaret, Stephanie; Robertson, Nicola; Golia Pernicka, Jennifer; Molinari, Nicolas; Hötker, Andreas M; Ehdaie, Behfar; Sala, Evis; Hricak, Hedvig; Vargas, Hebert Alberto
2017-07-01
To assess the performance of the updated Prostate Imaging Reporting and Data System (PI-RADSv2) and the apparent diffusion coefficient (ADC) for predicting confirmatory biopsy results in patients considered for active surveillance of prostate cancer (PCA). IRB-approved, retrospective study of 371 consecutive men with clinically low-risk PCA (initial biopsy Gleason score ≤6, prostate-specific antigen <10 ng/ml, clinical stage ≤T2a) who underwent 3T-prostate MRI before confirmatory biopsy. Two independent radiologists recorded the PI-RADSv2 scores and measured the corresponding ADC values in each patient. A composite score was generated to assess the performance of combining PI-RADSv2 + ADC. PCA was upgraded on confirmatory biopsy in 107/371 (29%) patients. Inter-reader agreement was substantial (PI-RADSv2: k = 0.73; 95% CI [0.66-0.80]; ADC: r = 0.74; 95% CI [0.69-0.79]). Accuracies, sensitivities, specificities, positive predicted value and negative predicted value of PI-RADSv2 were 85, 89, 83, 68, 95 and 78, 82, 76, 58, 91% for ADC. PI-RADSv2 accuracy was significantly higher than that of ADC for predicting biopsy upgrade (p = 0.014). The combined PI-RADSv2 + ADC composite score did not perform better than PI-RADSv2 alone. Obviating biopsy in patients with PI-RADSv2 score ≤3 would have missed Gleason Score upgrade in 12/232 (5%) of patients. PI-RADSv2 was superior to ADC measurements for predicting PCA upgrading on confirmatory biopsy.
Surov, Alexey; Meyer, Hans Jonas; Winter, Karsten; Richter, Cindy; Hoehn, Anna-Kathrin
2018-05-04
Our purpose was to analyze associations between apparent diffusion coefficient (ADC) histogram analysis parameters and histopathologicalfeatures in head and neck squamous cell carcinoma (HNSCC). The study involved 32 patients with primary HNSCC. For every tumor, the following histogram analysis parameters were calculated: ADCmean, ADCmax, ADC min , ADC median , ADC mode , P10, P25, P75, P90, kurtosis, skewness, and entropy. Furthermore, proliferation index KI 67, cell count, total and average nucleic areas were estimated. Spearman's correlation coefficient (p) was used to analyze associations between investigated parameters. In overall sample, all ADC values showed moderate inverse correlations with KI 67. All ADC values except ADCmax correlated inversely with tumor cellularity. Slightly correlations were identified between total/average nucleic area and ADC mean , ADC min , ADC median , and P25. In G1/2 tumors, only ADCmode correlated well with Ki67. No statistically significant correlations between ADC parameters and cellularity were found. In G3 tumors, Ki 67 correlated with all ADC parameters except ADCmode. Cell count correlated well with all ADC parameters except ADCmax. Total nucleic area correlated inversely with ADC mean , ADC min , ADC median , P25, and P90. ADC histogram parameters reflect proliferation potential and cellularity in HNSCC. The associations between histopathology and imaging depend on tumor grading.
Technique of diffusion weighted imaging and its application in stroke
NASA Astrophysics Data System (ADS)
Li, Enzhong; Tian, Jie; Han, Ying; Wang, Huifang; Li, Wu; He, Huiguang
2003-05-01
To study the application of diffusion weighted imaging and image post processing in the diagnosis of stroke, especially in acute stroke, 205 patients were examined by 1.5 T or 1.0 T MRI scanner and the images such as T1, T2 and diffusion weighted images were obtained. Image post processing was done with "3D Med System" developed by our lab to analyze data and acquire the apparent diffusion coefficient (ADC) map. In acute and subacute stage of stroke, the signal in cerebral infarction areas changed to hyperintensity in T2- and diffusion-weighted images, normal or hypointensity in T1-weighted images. In hyperacute stage, however, the signal was hyperintense just in the diffusion weighted imaes; others were normal. In the chronic stage, the signal in T1- and diffusion-weighted imaging showed hypointensity and hyperintensity in T2 weighted imaging. Because ADC declined obviously in acute and subacute stage of stroke, the lesion area was hypointensity in ADC map. With the development of the disease, ADC gradually recovered and then changed to hyperintensity in ADC map in chronic stage. Using diffusion weighted imaging and ADC mapping can make a diagnosis of stroke, especially in the hyperacute stage of stroke, and can differentiate acute and chronic stroke.
Rosenblum, Sara
2013-01-01
Planning ahead and organizational abilities in time and space are ingredients of high-level cognitive functions labeled as ‘Executive Functions’ (EF) required for daily activities such as writing or home management. EF deficits are considered a possible underlying brain mechanism involved in Developmental Coordination Disorders (DCD). The aim: of the study was to compare the handwriting process measures and the planning and organizational abilities in space and time of students with DCD with those of matched controls and to find whether handwriting measures can predict daily planning and organizational abilities among students with DCD. Method: 30 students diagnosed with DCD, between the ages of 24–41, and 30 age- and gender-matched controls participated in the study. They filled out the Handwriting Proficiency Screening Questionnaire (HPSQ) and the Adult Developmental Co-ordination Disorders Checklist (ADC). Furthermore, they copied a paragraph on a digitizer that is part of a computerized system Computerised Penmanship Evaluation Toll (ComPET). Results: Significant group differences were found for the HPSQ subscales scores as well as for the temporal and spatial measures of the paragraph copy task. Significant group differences were also found for the planning and organizational abilities in space and time as reflected through the ADC subscales. Significant medium correlations were found in both groups between the mean HPSQ time subscale and the ADC-B subscale mean score (r = 0.50/0.58, p < 0.05). Series of regression analyses indicated that two handwriting performance measures (mean HPSQ time subscale and mean stroke duration) predicted 19% of planning and organizational abilities as reflected through daily functions (ADC-B) [F(3, 54) = 38.37, β = 0.40, p < 0.0001]. Conclusion: The results support previous evidence about EF deficits as an underlying brain mechanism involved in motor coordination disorders, their significance as related to theoretical models of handwriting and daily function among DCD will be examined. PMID:23805113
Wang, Yan-Jun; Xu, Xiao-Quan; Hu, Hao; Su, Guo-Yi; Shen, Jie; Shi, Hai-Bin; Wu, Fei-Yun
2018-06-01
Background To clarify the nature of cervical malignant lymphadenopathy is highly important for the diagnosis and differential diagnosis of head and neck tumors. Purpose To investigate the role of first-order apparent diffusion coefficient (ADC) histogram analysis for differentiating lymphoma from metastatic lymph nodes of squamous cell carcinoma (SCC) in the head and neck region. Material and Methods Diffusion-weighted imaging (DWI) data of 67 patients (lymphoma, n = 20; SCC, n = 47) with malignant lymphadenopathy were retrospectively analyzed. The SCC group was divided into nasopharyngeal SCC and non-nasopharyngeal SCC groups. The ADC histogram features (ADC 10 , ADC 25 , ADC mean , ADC median , ADC 75 , ADC 90 , skewness, and kurtosis) were derived and then compared by independent-samples t-test and one-way analysis of variance test, respectively. Receiver operating characteristic curve analyses were employed to investigate diagnostic performance of the significant parameters. Results Lymphoma showed significantly lower ADC mean , ADC median , ADC 75 , and ADC 90 than SCC (all P < 0.05). Setting ADC 90 = 0.719 × 10 -3 mm 2 /s as the threshold value, optimal diagnostic performance was achieved (area under the curve [AUC] = 0.719, sensitivity = 95.7%, specificity = 50.0%). Subgroup analyses showed no significant difference between lymphoma and NPC (all P > 0.05). Lymphoma showed significantly lower ADC 25 , ADC mean , ADC median , ADC 75 , and ADC 90 than non-nasopharyngeal SCC (all P < 0.05). Optimal diagnostic performance (AUC = 0.847, sensitivity = 86.7%, specificity = 80.0%) could be achieved when setting ADC 90 = 0.943 × 10 -3 mm 2 /s as the threshold value. Conclusion Given its limitations, our study has shown that first-order ADC histogram analysis is capable of differentiating lymphoma from metastatic lymph nodes of SCC, especially those of non-nasopharyngeal SCC.
Lebovici, Andrei; Sfrangeu, Silviu A; Feier, Diana; Caraiani, Cosmin; Lucan, Ciprian; Suciu, Mihai; Elec, Florin; Iacob, Gheorghita; Buruian, Mircea
2014-05-10
We tested the feasibility of a simple method for assessment of prostate cancer (PCa) aggressiveness using diffusion-weighted magnetic resonance imaging (MRI) to calculate apparent diffusion coefficient (ADC) ratios between prostate cancer and healthy prostatic tissue. The requirement for institutional review board approval was waived. A set of 20 standardized core transperineal saturation biopsy specimens served as the reference standard for placement of regions of interest on ADC maps in tumorous and normal prostatic tissue of 22 men with PCa (median Gleason score: 7; range, 6-9). A total of 128 positive sectors were included for evaluation. Two diagnostic ratios were computed between tumor ADCs and normal sector ADCs: the ADC peripheral ratio (the ratio between tumor ADC and normal peripheral zone tissue, ADC-PR), and the ADC central ratio (the ratio between tumor ADC and normal central zone tissue, ADC-CR). The performance of the two ratios in detecting high-risk tumor foci (Gleason 8 and 9) was assessed using the area under the receiver operating characteristic curve (AUC). Both ADC ratios presented significantly lower values in high-risk tumors (0.48 ± 0.13 for ADC-CR and 0.40 ± 0.09 for ADC-PR) compared with low-risk tumors (0.66 ± 0.17 for ADC-CR and 0.54 ± 0.09 for ADC-PR) (p < 0.001) and had better diagnostic performance (ADC-CR AUC = 0.77, sensitivity = 82.2%, specificity = 66.7% and ADC-PR AUC = 0.90, sensitivity = 93.7%, specificity = 80%) than stand-alone tumor ADCs (AUC of 0.75, sensitivity = 72.7%, specificity = 70.6%) for identifying high-risk lesions. The ADC ratio as an intrapatient-normalized diagnostic tool may be better in detecting high-grade lesions compared with analysis based on tumor ADCs alone, and may reduce the rate of biopsies.
2014-01-01
Background We tested the feasibility of a simple method for assessment of prostate cancer (PCa) aggressiveness using diffusion-weighted magnetic resonance imaging (MRI) to calculate apparent diffusion coefficient (ADC) ratios between prostate cancer and healthy prostatic tissue. Methods The requirement for institutional review board approval was waived. A set of 20 standardized core transperineal saturation biopsy specimens served as the reference standard for placement of regions of interest on ADC maps in tumorous and normal prostatic tissue of 22 men with PCa (median Gleason score: 7; range, 6–9). A total of 128 positive sectors were included for evaluation. Two diagnostic ratios were computed between tumor ADCs and normal sector ADCs: the ADC peripheral ratio (the ratio between tumor ADC and normal peripheral zone tissue, ADC-PR), and the ADC central ratio (the ratio between tumor ADC and normal central zone tissue, ADC-CR). The performance of the two ratios in detecting high-risk tumor foci (Gleason 8 and 9) was assessed using the area under the receiver operating characteristic curve (AUC). Results Both ADC ratios presented significantly lower values in high-risk tumors (0.48 ± 0.13 for ADC-CR and 0.40 ± 0.09 for ADC-PR) compared with low-risk tumors (0.66 ± 0.17 for ADC-CR and 0.54 ± 0.09 for ADC-PR) (p < 0.001) and had better diagnostic performance (ADC-CR AUC = 0.77, sensitivity = 82.2%, specificity = 66.7% and ADC-PR AUC = 0.90, sensitivity = 93.7%, specificity = 80%) than stand-alone tumor ADCs (AUC of 0.75, sensitivity = 72.7%, specificity = 70.6%) for identifying high-risk lesions. Conclusions The ADC ratio as an intrapatient-normalized diagnostic tool may be better in detecting high-grade lesions compared with analysis based on tumor ADCs alone, and may reduce the rate of biopsies. PMID:24885552
NASA Astrophysics Data System (ADS)
Nasir, Z.; Ruslan, S. H.
2017-08-01
A sample and hold (S/H) block is typically used as an analogue to digital interface in the analogue to digital converter (ADC) system. Since ADC is widely used in processing signals, the power consumption of the ADC must be lowered to conserve energy. Therefore the S/H circuit must be of a low powered too. Sampling phase and hold phase are the two phases of the operation cycle of the S/H circuit. Switched capacitor (SC) techniques have been developed in order to allow the integration on a single silicon chip of both digital and analogue functions. By controlling switches around the SC, the SC circuit works by passing charge into and out of a capacitor. SC circuits are suitable for on chip implementations because they replace a resistor with switches and capacitors. In this research, a closed-loop sample and hold circuit based on SC is designed and simulated with Cadence EDA tools. The schematic, layout, and simulation of the circuit is done using generic Silterra 130 nm technology file. All the analysis is done using Virtuoso Analog Design Environment. Layout and schematic are drawn using Virtuoso Schematic Editor and Virtuoso Layout Editor, Calibre is used for post layout simulation. The closed loop S/H circuit based on SC is successfully designed and able to sample and hold the analogue input waveform. The power consumption of the circuit is 0.919 mW and the propagation delay is 64.96 ps.
Viswanathan, Anand; Patel, Pratik; Rahman, Rosanna; Nandigam, R N Kaveer; Kinnecom, Catherine; Bracoud, Luc; Rosand, Jonathan; Chabriat, Hugues; Greenberg, Steven M; Smith, Eric E
2008-07-01
Cerebral amyloid angiopathy (CAA) is a major cause of lobar intracerebral hemorrhage and cognitive impairment and is associated with white matter hyperintensities and cerebral microbleeds. MRI diffusion tensor imaging detects microstructural tissue damage in advanced CAA even in areas that appear normal on conventional MRI. We hypothesized that higher global mean apparent diffusion coefficient (mean ADC), reflecting a higher amount of chronic tissue disruption caused by CAA, would be independently associated with CAA-related cognitive impairment. Preintracerebral hemorrhage cognitive impairment was systematically assessed using a standardized questionnaire (IQCODE) in 49 patients. Volume of white matter hyperintensities, number of microbleeds, and mean ADC were determined from MRIs obtained within 14.0+/-22.5 days of intracerebral hemorrhage cognitive impairment. White matter hyperintensities and mean ADC were measured in the hemisphere uninvolved by intracerebral hemorrhage to avoid confounding. Preintracerebral hemorrhage cognitive impairment was identified in 10 of 49 subjects. Mean ADC was the only variable associated with preintracerebral hemorrhage cognitive impairment and was elevated in those with preintracerebral hemorrhage cognitive impairment compared with those without (12.4x10(-4) versus 11.7x10(-4) mm(2)/s; P=0.03). Mean ADC positively correlated with age but not white matter hyperintensities or number of microbleeds. In logistic regression controlling for age and visible cerebral atrophy, mean ADC was independently associated with preintracerebral hemorrhage cognitive impairment (OR per 1x10(-4) mm(2)/s increase=2.45, 95% CI 1.11 to 5.40, P=0.04). Mean ADC is independently associated with preintracerebral hemorrhage cognitive impairment in CAA. The lack of correlation with other MRI markers of CAA suggests that mean ADC may be sensitive to distinct aspects of CAA pathology and its tissue consequences. These results suggest that global MRI diffusion changes are sensitive to clinically relevant microstructural alterations and may be useful markers of CAA-related tissue damage.
Viswanathan, Anand; Patel, Pratik; Rahman, Rosanna; Nandigam, R.N. Kaveer; Kinnecom, Catherine; Bracoud, Luc; Rosand, Jonathan; Chabriat, Hugues; Greenberg, Steven M.; Smith, Eric E.
2009-01-01
Background and Purpose Cerebral amyloid angiopathy (CAA) is a major cause of lobar intracerebral hemorrhage and cognitive impairment and is associated with white matter hyperintensities and cerebral microbleeds. MRI diffusion tensor imaging detects microstructural tissue damage in advanced CAA even in areas that appear normal on conventional MRI. We hypothesized that higher global mean apparent diffusion coefficient (mean ADC), reflecting a higher amount of chronic tissue disruption caused by CAA, would be independently associated with CAA-related cognitive impairment. Methods Preintracerebral hemorrhage cognitive impairment was systematically assessed using a standardized questionnaire (IQCODE) in 49 patients. Volume of white matter hyperintensities, number of microbleeds, and mean ADC were determined from MRIs obtained within 14.0±22.5 days of intracerebral hemorrhage cognitive impairment. White matter hyperintensities and mean ADC were measured in the hemisphere uninvolved by intracerebral hemorrhage to avoid confounding. Results Preintracerebral hemorrhage cognitive impairment was identified in 10 of 49 subjects. Mean ADC was the only variable associated with preintracerebral hemorrhage cognitive impairment and was elevated in those with preintracerebral hemorrhage cognitive impairment compared with those without (12.4×10-4 versus 11.7×10-4 mm2/s; P=0.03). Mean ADC positively correlated with age but not white matter hyperintensities or number of microbleeds. In logistic regression controlling for age and visible cerebral atrophy, mean ADC was independently associated with preintracerebral hemorrhage cognitive impairment (OR per 1×10-4 mm2/s increase=2.45, 95% CI 1.11 to 5.40, P=0.04). Conclusions Mean ADC is independently associated with preintracerebral hemorrhage cognitive impairment in CAA. The lack of correlation with other MRI markers of CAA suggests that mean ADC may be sensitive to distinct aspects of CAA pathology and its tissue consequences. These results suggest that global MRI diffusion changes are sensitive to clinically relevant microstructural alterations and may be useful markers of CAA-related tissue damage. PMID:18436874
Kamphuis, P J G H; Verhey, F R J; Olde Rikkert, M G M; Twisk, J W R; Swinkels, S H N; Scheltens, P
2011-08-01
To investigate the effect of a medical food (Souvenaid) on body mass index (BMI) and functional abilities in patients with mild Alzheimer's disease (AD). DESIGN/SETTING/PARTICIPANTS/INTERVENTION /MEASUREMENTS: These analyses were performed on data from a 12-week, double-blind, randomized, controlled, multicenter, proof-of-concept study with a similarly designed and exploratory 12-week extension period. Patients with mild AD (Mini-Mental State Examination score of 20-26) were randomized to receive either the active product or an iso-caloric control product. While primary outcomes included measures of cognition, the 23-item Alzheimer's Disease Cooperative Study-Activities of Daily Living (ADCS-ADL) scale was included as a secondary outcome. Both ADCS-ADL and BMI were assessed at baseline and Weeks 6, 12 and 24. Data were analyzed using a repeated-measures mixed model. Overall, data suggested an increased BMI in the active versus the control group at Week 24 (ITT: p = 0.07; PP: p = 0.03), but no treatment effect on ADCS-ADL was observed. However, baseline BMI was found to be a significant treatment effect modifier (ITT: p = 0.04; PP: p = 0.05), and an increase in ADCS-ADL was observed at Week 12 in patients with a 'low' baseline BMI (ITT: p = 0.02; PP: p = 0.04). These data indicate that baseline BMI significantly impacts the effect of Souvenaid on functional abilities. In addition, there was a suggestion that Souvenaid increased BMI.
Jerome, Neil P; Orton, Matthew R; d'Arcy, James A; Collins, David J; Koh, Dow-Mu; Leach, Martin O
2014-01-01
To evaluate the effect on diffusion-weighted image-derived parameters in the apparent diffusion coefficient (ADC) and intra-voxel incoherent motion (IVIM) models from choice of either free-breathing or navigator-controlled acquisition. Imaging was performed with consent from healthy volunteers (n = 10) on a 1.5T Siemens Avanto scanner. Parameter-matched free-breathing and navigator-controlled diffusion-weighted images were acquired, without averaging in the console, for a total scan time of ∼10 minutes. Regions of interest were drawn for renal cortex, renal pyramid, whole kidney, liver, spleen, and paraspinal muscle. An ADC diffusion model for these regions was fitted for b-values ≥ 250 s/mm(2) , using a Levenberg-Marquardt algorithm, and an IVIM model was fitted for all images using a Bayesian method. ADC and IVIM parameters from the two acquisition regimes show no significant differences for the cohort; individual cases show occasional discrepancies, with outliers in parameter estimates arising more commonly from navigator-controlled scans. The navigator-controlled acquisitions showed, on average, a smaller range of movement for the kidneys (6.0 ± 1.4 vs. 10.0 ± 1.7 mm, P = 0.03), but also a smaller number of averages collected (3.9 ± 0.1 vs. 5.5 ± 0.2, P < 0.01) in the allocated time. Navigator triggering offers no advantage in fitted diffusion parameters, whereas free-breathing appears to offer greater confidence in fitted diffusion parameters, with fewer outliers, for matched acquisition periods. Copyright © 2013 Wiley Periodicals, Inc.
Subgrid parameterization of snow distribution at a Mediterranean site using terrestrial photography
NASA Astrophysics Data System (ADS)
Pimentel, Rafael; Herrero, Javier; José Polo, María
2017-02-01
Subgrid variability introduces non-negligible scale effects on the grid-based representation of snow. This heterogeneity is even more evident in semiarid regions, where the high variability of the climate produces various accumulation melting cycles throughout the year and a large spatial heterogeneity of the snow cover. This variability in a watershed can often be represented by snow accumulation-depletion curves (ADCs). In this study, terrestrial photography (TP) of a cell-sized area (30 × 30 m) was used to define local snow ADCs at a Mediterranean site. Snow-cover fraction (SCF) and snow-depth (h) values obtained with this technique constituted the two datasets used to define ADCs. A flexible sigmoid function was selected to parameterize snow behaviour on this subgrid scale. It was then fitted to meet five different snow patterns in the control area: one for the accumulation phase and four for the melting phase in a cycle within the snow season. Each pattern was successfully associated with the snow conditions and previous evolution. The resulting ADCs were associated to certain physical features of the snow, which were used to incorporate them in the point snow model formulated by Herrero et al. (2009) by means of a decision tree. The final performance of this model was tested against field observations recorded over four hydrological years (2009-2013). The calibration and validation of this ADC snow model was found to have a high level of accuracy, with global RMSE values of 105.8 mm for the average snow depth and 0.21 m2 m-2 for the snow-cover fraction in the control area. The use of ADCs on the cell scale proposed in this research provided a sound basis for the extension of point snow models to larger areas by means of a gridded distributed calculation.
Ward, Phil; Counsell, Serena; Allsop, Joanna; Cowan, Frances; Shen, Yuji; Edwards, David; Rutherford, Mary
2006-04-01
Apparent diffusion coefficients (ADC) that are measured by diffusion-weighted imaging are reduced in severe white matter (WM) and in some severe basal ganglia and thalamic (BGT) injury in infants who present with hypoxic-ischemic encephalopathy (HIE). However, ADC values may pseudonormalize or even be high during this time in some less severe but clinically significant injuries. We hypothesized that fractional anisotropy (FA), a measure of the directional diffusivity of water made using diffusion tensor imaging, may be abnormal in these less severe injuries; therefore, the objective of this study was to use diffusion tensor imaging to measure ADC and FA in infants with moderate and severe hypoxic-ischemic brain injury. Twenty infants with HIE and 7 normal control infants were studied. All infants were born at >36 weeks' gestational age, and MRI scans were obtained within 3 weeks of delivery. Data were examined for normality, and comparisons were made using analysis of variance or Kruskal-Wallis as appropriate. During the first week, FA values were decreased with both severe and moderate WM and BGT injury as assessed by conventional imaging, whereas ADC values were reduced only in severe WM injury and some severe BGT injury. Abnormal ADC values pseudonormalized during the second week, whereas FA values continued to decrease. FA is reduced in moderate brain injury after HIE. A low FA may reflect a breakdown in WM organization. Moderate BGT injury may result in atrophy but not overt infarction; it is possible that delayed apoptosis is more marked than immediate necrosis, and this may account for normal early ADC values. The accompanying low FA within some severe and all moderate gray matter lesions, which is associated with significant later impairment, may help to confirm clinically significant abnormality in infants with normal ADC values.
Grejs, Anders Morten; Gjedsted, Jakob; Pedersen, Michael; Birke-Sørensen, Hanne; Rauff-Mortensen, Andreas; Andersen, Kristian Kjær; Kirkegaard, Hans
2016-12-01
The aim of this randomized porcine study was to compare surface targeted temperature management (TTM) to endovascular TTM evaluated by cerebral diffusion-weighted magnetic resonance imaging (MRI): apparent diffusion coefficient (ADC), and by intracerebral/intramuscular microdialysis. It is well known that alteration in the temperature affects ADC, but the relationship between cerebral ADC values and the cooling method per se has not been established. Eighteen anesthetized 60-kg female swine were hemodynamically and intracerebrally monitored and subsequently subjected to a baseline MRI. The animals were then randomized into three groups: (1) surface cooling (n = 6) at 33.5°C using EMCOOLSpad ® , (2) endovascular cooling (n = 6) at 33.5°C using an Icy ® cooling catheter with the CoolGard 3000 ® , or (3) control (n = 6) at 38.5°C using a Bair Hugger™. The swine were treated with TTM for 6 hours followed by a second MRI examination, including ADC. Blood and microdialysate were sampled regularly throughout the experiment, and glucose, lactate, pyruvate, glycerol, and the lactate/pyruvate ratio did not differ among groups, neither intracerebrally nor intramuscularly. Surface cooling yielded a significantly lower median ADC than endovascular cooling: 714 (634; 804) × 10 -6 mm 2 /s versus 866 (828; 927) × 10 -6 mm 2 /s, (p < 0.05). The surface cooling ADC was lowered to a range usually attributed to cytotoxic edema and these low values could not be explained solely by the temperature effect per se. To what extent the ADC is fully reversible at rewarming is unknown and the clinical implications should be further investigated in clinical studies.
Advanced Physiological Estimation of Cognitive Status. Part 2
2011-05-24
Neurofeedback Algorithms and Gaze Controller EEG Sensor System g.USBamp *, ** • internal 24-bit ADC and digital signal processor • 16 channels (expandable...SUBJECT TERMS EEG eye-tracking mental state estimation machine learning Leonard J. Trejo Pacific Development and Technology LLC 999 Commercial St. Palo...fatigue, overload) Technology Transfer Opportunity Technology from PDT – Methods to acquire various physiological signals ( EEG , EOG, EMG, ECG, etc
2014-03-27
Fault Detection and Isolation GUI Graphical User Interface IGRF International Geomagnetic Reference Field IMU Inertial Measurement Unit IR infrared xv...ADCS hardware components were either commercially purchased or built in-house and include an Inertial Measurement Unit ( IMU ), external magnetometer, 4...3.2.1.3 IMU . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 3.2.1.4 External Magnetometer . . . . . . . . . . . . . . . . . . 48 3.2.2
Iima, Mami; Kataoka, Masako; Kanao, Shotaro; Onishi, Natsuko; Kawai, Makiko; Ohashi, Akane; Sakaguchi, Rena; Toi, Masakazu; Togashi, Kaori
2018-05-01
Purpose To investigate the performance of integrated approaches that combined intravoxel incoherent motion (IVIM) and non-Gaussian diffusion parameters compared with the Breast Imaging and Reporting Data System (BI-RADS) to establish multiparameter thresholds scores or probabilities by using Bayesian analysis to distinguish malignant from benign breast lesions and their correlation with molecular prognostic factors. Materials and Methods Between May 2013 and March 2015, 411 patients were prospectively enrolled and 199 patients (allocated to training [n = 99] and validation [n = 100] sets) were included in this study. IVIM parameters (flowing blood volume fraction [fIVIM] and pseudodiffusion coefficient [D*]) and non-Gaussian diffusion parameters (theoretical apparent diffusion coefficient [ADC] at b value of 0 sec/mm 2 [ADC 0 ] and kurtosis [K]) by using IVIM and kurtosis models were estimated from diffusion-weighted image series (16 b values up to 2500 sec/mm 2 ), as well as a synthetic ADC (sADC) calculated by using b values of 200 and 1500 (sADC 200-1500 ) and a standard ADC calculated by using b values of 0 and 800 sec/mm 2 (ADC 0-800 ). The performance of two diagnostic approaches (combined parameter thresholds and Bayesian analysis) combining IVIM and diffusion parameters was evaluated and compared with BI-RADS performance. The Mann-Whitney U test and a nonparametric multiple comparison test were used to compare their performance to determine benignity or malignancy and as molecular prognostic biomarkers and subtypes of breast cancer. Results Significant differences were found between malignant and benign breast lesions for IVIM and non-Gaussian diffusion parameters (ADC 0 , K, fIVIM, fIVIM · D*, sADC 200-1500, and ADC 0-800 ; P < .05). Sensitivity and specificity for the validation set by radiologists A and B were as follows: sensitivity, 94.7% and 89.5%, and specificity, 75.0% and 79.2% for sADC 200-1500 , respectively; sensitivity, 94.7% and 96.1%, and specificity, 75.0% and 66.7%, for the combined thresholds approach, respectively; sensitivity, 92.1% and 92.1%, and specificity, 83.3% and 66.7%, for Bayesian analysis, respectively; and sensitivity and specificity, 100% and 79.2%, for BI-RADS, respectively. The significant difference in values of sADC 200-1500 in progesterone receptor status (P = .002) was noted. sADC 200-1500 was significantly different between histologic subtypes (P = .006). Conclusion Approaches that combined various IVIM and non-Gaussian diffusion MR imaging parameters may provide BI-RADS-equivalent scores almost comparable to BI-RADS categories without the use of contrast agents. Non-Gaussian diffusion parameters also differed by biologic prognostic factors. © RSNA, 2017 Online supplemental material is available for this article.
Wang, G J; Wang, Y; Ye, Y; Chen, F; Lu, Y T; Li, S L
2017-11-07
Objective: To investigate the features of apparent diffusion coefficient (ADC) histogram parameters based on entire tumor volume data in high resolution diffusion weighted imaging of nasopharyngeal carcinoma (NPC) and to evaluate its correlations with cancer stages. Methods: This retrospective study included 154 cases of NPC patients[102 males and 52 females, mean age (48±11) years]who had received readout segmentation of long variable echo trains of MRI scan before radiation therapy. The area of tumor was delineated on each section of axial ADC maps to generate ADC histogram by using Image J. ADC histogram of entire tumor along with the histogram parameters-the tumor voxels, ADC(mean), ADC(25%), ADC(50%), ADC(75%), skewness and kurtosis were obtained by merging all sections with SPSS 22.0 software. Intra-observer repeatability was assessed by using intra-class correlation coefficients (ICC). The patients were subdivided into two groups according to cancer volume: small cancer group (<305 voxels, about 2 cm(3)) and large cancer group (≥2 cm(3)). The correlation between ADC histogram parameters and cancer stages was evaluated with Spearman test. Results: The ICC of measuring ADC histogram parameters of tumor voxels, ADC(mean), ADC(25%), ADC(50%), ADC(75%), skewness, kurtosis was 0.938, 0.861, 0.885, 0.838, 0.836, 0.358 and 0.456, respectively. The tumor voxels was positively correlated with T staging ( r =0.368, P <0.05). There were significant differences in tumor voxels among patients with different T stages ( K =22.306, P <0.05). There were significant differences in the ADC(mean), ADC(25%), ADC(50%) among patients with different T stages in the small cancer group( K =8.409, 8.187, 8.699, all P <0.05), and the up-mentioned three indices were positively correlated with T staging ( r =0.221, 0.209, 0.235, all P <0.05). Skewness and kurtosis differed significantly between the groups with different cancer volume( t =-2.987, Z =-3.770, both P <0.05). Conclusion: The tumor volume, tissue uniformity of NPC are important factors affecting ADC and cancer stages, parameters of ADC histogram (ADC(mean), ADC(25%), ADC(50%)) increases with T staging in NPC smaller than 2 cm(3).
Liu, Song; Zhang, Yujuan; Chen, Ling; Guan, Wenxian; Guan, Yue; Ge, Yun; He, Jian; Zhou, Zhengyang
2017-10-02
Whole-lesion apparent diffusion coefficient (ADC) histogram analysis has been introduced and proved effective in assessment of multiple tumors. However, the application of whole-volume ADC histogram analysis in gastrointestinal tumors has just started and never been reported in T and N staging of gastric cancers. Eighty patients with pathologically confirmed gastric carcinomas underwent diffusion weighted (DW) magnetic resonance imaging before surgery prospectively. Whole-lesion ADC histogram analysis was performed by two radiologists independently. The differences of ADC histogram parameters among different T and N stages were compared with independent-samples Kruskal-Wallis test. Receiver operating characteristic (ROC) analysis was performed to evaluate the performance of ADC histogram parameters in differentiating particular T or N stages of gastric cancers. There were significant differences of all the ADC histogram parameters for gastric cancers at different T (except ADC min and ADC max ) and N (except ADC max ) stages. Most ADC histogram parameters differed significantly between T1 vs T3, T1 vs T4, T2 vs T4, N0 vs N1, N0 vs N3, and some parameters (ADC 5% , ADC 10% , ADC min ) differed significantly between N0 vs N2, N2 vs N3 (all P < 0.05). Most parameters except ADC max performed well in differentiating different T and N stages of gastric cancers. Especially for identifying patients with and without lymph node metastasis, the ADC 10% yielded the largest area under the ROC curve of 0.794 (95% confidence interval, 0.677-0.911). All the parameters except ADC max showed excellent inter-observer agreement with intra-class correlation coefficients higher than 0.800. Whole-volume ADC histogram parameters held great potential in differentiating different T and N stages of gastric cancers preoperatively.
Ren, Jiliang; Yuan, Ying; Wu, Yingwei; Tao, Xiaofeng
2018-05-02
The overlap of morphological feature and mean ADC value restricted clinical application of MRI in the differential diagnosis of orbital lymphoma and idiopathic orbital inflammatory pseudotumor (IOIP). In this paper, we aimed to retrospectively evaluate the combined diagnostic value of conventional magnetic resonance imaging (MRI) and whole-tumor histogram analysis of apparent diffusion coefficient (ADC) maps in the differentiation of the two lesions. In total, 18 patients with orbital lymphoma and 22 patients with IOIP were included, who underwent both conventional MRI and diffusion weighted imaging before treatment. Conventional MRI features and histogram parameters derived from ADC maps, including mean ADC (ADC mean ), median ADC (ADC median ), skewness, kurtosis, 10th, 25th, 75th and 90th percentiles of ADC (ADC 10 , ADC 25 , ADC 75 , ADC 90 ) were evaluated and compared between orbital lymphoma and IOIP. Multivariate logistic regression analysis was used to identify the most valuable variables for discriminating. Differential model was built upon the selected variables and receiver operating characteristic (ROC) analysis was also performed to determine the differential ability of the model. Multivariate logistic regression showed ADC 10 (P = 0.023) and involvement of orbit preseptal space (P = 0.029) were the most promising indexes in the discrimination of orbital lymphoma and IOIP. The logistic model defined by ADC 10 and involvement of orbit preseptal space was built, which achieved an AUC of 0.939, with sensitivity of 77.30% and specificity of 94.40%. Conventional MRI feature of involvement of orbit preseptal space and ADC histogram parameter of ADC 10 are valuable in differential diagnosis of orbital lymphoma and IOIP.
Surov, Alexey; Meyer, Hans Jonas; Wienke, Andreas
2017-07-01
Diffusion-weighted imaging (DWI) is a magnetic resonance imaging (MRI) technique based on measure of water diffusion that can provide information about tissue microstructure, especially about cell count. Increase of cell density induces restriction of water diffusion and decreases apparent diffusion coefficient (ADC). ADC can be divided into three sub-parameters: ADC minimum or ADC min , mean ADC or ADC mean and ADC maximum or ADC max Some studies have suggested that ADC min shows stronger correlations with cell count in comparison to other ADC fractions and may be used as a parameter for estimation of tumor cellularity. The aim of the present meta-analysis was to summarize correlation coefficients between ADC min and cellularity in different tumors based on large patient data. For this analysis, MEDLINE database was screened for associations between ADC and cell count in different tumors up to September 2016. For this work, only data regarding ADC min were included. Overall, 12 publications with 317 patients were identified. Spearman's correlation coefficient was used to analyze associations between ADC min and cellularity. The reported Pearson correlation coefficients in some publications were converted into Spearman correlation coefficients. The pooled correlation coefficient for all included studies was ρ=-0.59 (95% confidence interval (CI)=-0.72 to -0.45), heterogeneity Tau 2 =0.04 (p<0.0001), I 2 =73%, test for overall effect Z=8.67 (p<0.00001). ADC min correlated moderately with tumor cellularity. The calculated correlation coefficient is not stronger in comparison to the reported coefficient for ADC mean and, therefore, ADC min does not represent a better means to reflect cellularity. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
Wu, X; Reinikainen, P; Vanhanen, A; Kapanen, M; Vierikko, T; Ryymin, P; Hyödynmaa, S; Kellokumpu-Lehtinen, P-L
2017-01-01
To investigate whether diffusion-weighted imaging (DWI) apparent diffusion coefficient (ADC) correlates with prostate cancer aggressiveness and further to compare the diagnostic performance of ADC and normalized ADC (nADC: normalized to non-tumor tissue). Thirty pre-treatment patients (mean age, 69years; range: 59-78years) with prostate cancer underwent magnetic resonance imaging (MRI) examination, including DWI with three b values: 50, 400, and 800s/mm 2 . Both ADC and nADC were correlated with the Gleason score obtained through transrectal ultrasound-guided biopsy. The tumor minimum ADC (ADC min : the lowest ADC value within tumor) had an inverse correlation with the Gleason score (r=-0.43, P<0.05), and it was lower in patients with Gleason score 3+4 than in those with Gleason score 3+3 (0.54±0.11×10 3 mm 2 /s vs. 0.64±0.12×10 -3 mm 2 /s, P<0.05). Both the nADC min and nADC mean correlated with the Gleason score (r=-0.52 and r=-0.55, P<0.01; respectively), and they were lower in patients with Gleason score 3+4 than those with Gleason score 3+3 (P<0.01; respectively). Receiver operating characteristic (ROC) analysis showed that the area under the ROC curve was 0.765, 0.818, or 0.833 for the ADC min , nADC min , or nADC mean ; respectively, in differentiating between Gleason score 3+4 and 3+3 tumors. Tumor ADC min , nADC min , and nADC mean are useful markers to predict the aggressiveness of prostate cancer. Copyright © 2016 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Development of COTS ADC SEE Test System for the ATLAS LArCalorimeter Upgrade
Hu, Xue -Ye; Chen, Hu -Cheng; Chen, Kai; ...
2014-12-01
Radiation-tolerant, high speed, high density and low power commercial off-the-shelf (COTS) analog-to-digital converters (ADCs) are planned to be used in the upgrade to the Liquid Argon (LAr) calorimeter front end (FE) trigger readout electronics. Total ionization dose (TID) and single event effect (SEE) are two important radiation effects which need to be characterized on COTS ADCs. In our initial TID test, Texas Instruments (TI) ADS5272 was identified to be the top performer after screening a total 17 COTS ADCs from different manufacturers with dynamic range and sampling rate meeting the requirements of the FE electronics. Another interesting feature of ADS5272more » is its 6.5 clock cycles latency, which is the shortest among the 17 candidates. Based on the TID performance, we have designed a SEE evaluation system for ADS5272, which allows us to further assess its radiation tolerance. In this paper, we present a detailed design of ADS5272 SEE evaluation system and show the effectiveness of this system while evaluating ADS5272 SEE characteristics in multiple irradiation tests. According to TID and SEE test results, ADS5272 was chosen to be implemented in the full-size LAr Trigger Digitizer Board (LTDB) demonstrator, which will be installed on ATLAS calorimeter during the 2014 Long Shutdown 1 (LS1).« less
Malyarenko, Dariya; Newitt, David; Wilmes, Lisa; Tudorica, Alina; Helmer, Karl G.; Arlinghaus, Lori R.; Jacobs, Michael A.; Jajamovich, Guido; Taouli, Bachir; Yankeelov, Thomas E.; Huang, Wei; Chenevert, Thomas L.
2015-01-01
Purpose Characterize system-specific bias across common magnetic resonance imaging (MRI) platforms for quantitative diffusion measurements in multicenter trials. Methods Diffusion weighted imaging (DWI) was performed on an ice-water phantom along the superior-inferior (SI) and right-left (RL) orientations spanning ±150 mm. The same scanning protocol was implemented on 14 MRI systems at seven imaging centers. The bias was estimated as a deviation of measured from known apparent diffusion coefficient (ADC) along individual DWI directions. The relative contributions of gradient nonlinearity, shim errors, imaging gradients and eddy currents were assessed independently. The observed bias errors were compared to numerical models. Results The measured systematic ADC errors scaled quadratically with offset from isocenter, and ranged between −55% (SI) and 25% (RL). Nonlinearity bias was dependent on system design and diffusion gradient direction. Consistent with numerical models, minor ADC errors (±5%) due to shim, imaging and eddy currents were mitigated by double echo DWI and image co-registration of individual gradient directions. Conclusion The analysis confirms gradient nonlinearity as a major source of spatial DW bias and variability in off-center ADC measurements across MRI platforms, with minor contributions from shim, imaging gradients and eddy currents. The developed protocol enables empiric description of systematic bias in multicenter quantitative DWI studies. PMID:25940607
Malyarenko, Dariya I; Newitt, David; J Wilmes, Lisa; Tudorica, Alina; Helmer, Karl G; Arlinghaus, Lori R; Jacobs, Michael A; Jajamovich, Guido; Taouli, Bachir; Yankeelov, Thomas E; Huang, Wei; Chenevert, Thomas L
2016-03-01
Characterize system-specific bias across common magnetic resonance imaging (MRI) platforms for quantitative diffusion measurements in multicenter trials. Diffusion weighted imaging (DWI) was performed on an ice-water phantom along the superior-inferior (SI) and right-left (RL) orientations spanning ± 150 mm. The same scanning protocol was implemented on 14 MRI systems at seven imaging centers. The bias was estimated as a deviation of measured from known apparent diffusion coefficient (ADC) along individual DWI directions. The relative contributions of gradient nonlinearity, shim errors, imaging gradients, and eddy currents were assessed independently. The observed bias errors were compared with numerical models. The measured systematic ADC errors scaled quadratically with offset from isocenter, and ranged between -55% (SI) and 25% (RL). Nonlinearity bias was dependent on system design and diffusion gradient direction. Consistent with numerical models, minor ADC errors (± 5%) due to shim, imaging and eddy currents were mitigated by double echo DWI and image coregistration of individual gradient directions. The analysis confirms gradient nonlinearity as a major source of spatial DW bias and variability in off-center ADC measurements across MRI platforms, with minor contributions from shim, imaging gradients and eddy currents. The developed protocol enables empiric description of systematic bias in multicenter quantitative DWI studies. © 2015 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Abbasi, S.; Galioglu, A.; Shafique, A.; Ceylan, O.; Yazici, M.; Gurbuz, Y.
2017-02-01
A 32x32 prototype of a digital readout IC (DROIC) for medium-wave infrared focal plane arrays (MWIR IR-FPAs) is presented. The DROIC employs in-pixel photocurrent to digital conversion based on a pulse frequency modulation (PFM) loop and boasts a novel feature of off-pixel residue conversion using 10-bit column SAR ADCs. The remaining charge at the end of integration in typical PFM based digital pixel sensors is usually wasted. Previous works employing in-pixel extended counting methods make use of extra memory and counters to convert this left-over charge to digital, thereby performing fine conversion of the incident photocurrent. This results in a low quantization noise and hence keeps the readout noise low. However, focal plane arrays (FPAs) with small pixel pitch are constrained in pixel area, which makes it difficult to benefit from in-pixel extended counting circuitry. Thus, in this work, a novel approach to measure the residue outside the pixel using column -parallel SAR ADCs has been proposed. Moreover, a modified version of the conventional PFM based pixel has been designed to help hold the residue charge and buffer it to the column ADC. In addition to the 2D array of pixels, the prototype consists of 32 SAR ADCs, a timing controller block and a memory block to buffer the residue data coming out of the ADCs. The prototype has been designed and fabricated in 90nm CMOS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joerger, F. A.
1990-02-01
This project was to develop five transient recorder modules of various speeds and features. Four of the modules; TR200, 200MHZ recorder; TR2/25, Dual 25MHZ recorder; TR1012, 10MHZ, 12 bit recorder, and the ADC3216, 32 channel, 16 bit recorder were developed in the international CAMAC standard. The fifth unit, VTR1, 25MHZ recorder was packaged in the VME standard. Three of the modules, Models TR200, TR2/25 and VTR1 are already in Phase 3. The ADC3216 has been prototyped and successfully evaluated by a number of customers. The last module, Model TR1012, has been completely designed and the artwork completed. This module willmore » undergo tests shortly. 4 figs.« less
Koczwara, Anna; Tavabie, Abdol; Patterson, Fiona
2011-11-01
This paper describes a longitudinal evaluation of six pilot medical appraiser development centres (ADCs) with GPs held between February and September 2009 in the Kent, Surrey and Sussex Deanery. The ADCs were developed using traditional development centre methods and incorporated the concept of emotional intelligence (El). Initial evaluation results have shown positive short-term outcomes relating to appraiser skills and self-confidence as well as transfer of learning. This paper extends this earlier evaluation by looking at appraiser and appraisee feedback approximately one year after the ADCs using a validated framework for training evaluation. We discuss the long-term affective, cognitive and behavioural learning outcomes and the impact participation in the ADCs has on the broader healthcare system, including effects upon patient care and safety. Limitations of the current project and opportunities for future research are discussed.
Nicolas, R; Gros-Dagnac, H; Aubry, F; Celsis, P
2017-06-01
The blood oxygen level-dependent (BOLD) effect is extensively used for functional MRI (fMRI) but presents some limitations. Diffusion-weighted fMRI (DfMRI) has been proposed as a method more tightly linked to neuronal activity. This work proposes a protocol of DfMRI acquired for several b-values and diffusion directions that is compared to gradient-echo BOLD (GE-BOLD) and to repeated spin-echo BOLD (SE-BOLD, acquisitions performed with b=0s/mm 2 ), which was also used to ensure the reproducibility of the response. A block stimulation paradigm of the primary visual system (V1) was performed in 12 healthy subjects with checkerboard alternations (2Hz frequency). DfMRI was performed at 3T with 5 b-values (b=1500, 1000, 500, 250, 0s/mm 2 ) with TR/TE=1004/93ms, Δ/δ=45.4ms/30ms, and 6 spatial directions for diffusion measures. GE-BOLD was performed with a similar block stimulation design timing. Apparent Diffusion Coefficient (ADC)-fMRI was computed with all b-values used. An identical Z-score level was used for all fMRI modalities for the comparison of volumes of activation. ADC-fMRI and SE-BOLD fMRI activation locations were compared in a voxel-based analysis to a cytoarchitectural probability map of V1. SE-BOLD activation volumes represented only 55% of the GE-BOLD activation volumes (P<0.0001). DfMRI activation volumes averaged for all b-values acquired represented only 12% of GE-BOLD (P<0.0001) and only 22% of SE-BOLD activation volumes (P<0.005). Compared to SE-BOLD-fMRI, ADC-fMRI activations showed fewer pixels outside of V1 and a higher average probability of belonging to V1. DfMRI and ADC-fMRI acquisition at 3T could be easily post-processed with common neuro-imaging software. DfMRI and ADC-fMRI activation volumes were significantly smaller than those obtained with SE-BOLD. ADC-fMRI activations were more precisely localized in V1 than those of SE-BOLD-fMRI. This validated the increased capability of ADC-fMRI compared to BOLD to enhance the precision of localizing an fMRI activation in the cyto-architectural zone V1, thereby justifying the use of ADC-fMRI for neuro-scientific studies. Copyright © 2017 Elsevier Inc. All rights reserved.
Wakefield, Douglas S; Ward, Marcia M; Loes, Jean L; O'Brien, John
2010-01-01
We report how seven independent critical access hospitals collaborated with a rural referral hospital to standardize workflow policies and procedures while jointly implementing the same health information technologies (HITs) to enhance medication care processes. The study hospitals implemented the same electronic health record, computerized provider order entry, pharmacy information systems, automated dispensing cabinets (ADC), and barcode medication administration systems. We conducted interviews and examined project documents to explore factors underlying the successful implementation of ADC and barcode medication administration across the network hospitals. These included a shared culture of collaboration; strategic sequencing of HIT component implementation; interface among HIT components; strategic placement of ADCs; disciplined use and sharing of workflow analyses linked with HIT applications; planning for workflow efficiencies; acquisition of adequate supply of HIT-related devices; and establishing metrics to monitor HIT use and outcomes.
Suo, Shi-Teng; Chen, Xiao-Xi; Fan, Yu; Wu, Lian-Ming; Yao, Qiu-Ying; Cao, Meng-Qiu; Liu, Qiang; Xu, Jian-Rong
2014-08-01
To investigate the potential value of histogram analysis of apparent diffusion coefficient (ADC) obtained at standard (700 s/mm(2)) and high (1500 s/mm(2)) b values on a 3.0-T scanner in the differentiation of bladder cancer from benign lesions and in assessing bladder tumors of different pathologic T stages and to evaluate the diagnostic performance of ADC-based histogram parameters. In all, 52 patients with bladder lesions, including benign lesions (n = 7) and malignant tumors (n = 45; T1 stage or less, 23; T2 stage, 7; T3 stage, 8; and T4 stage, 7), were retrospectively evaluated. Magnetic resonance examination at 3.0 T and diffusion-weighted imaging were performed. ADC maps were obtained at two b values (b = 700 and 1500 s/mm(2); ie, ADC-700 and ADC-1500). Parameters of histogram analysis included mean, kurtosis, skewness, and entropy. The correlations between these parameters and pathologic results were revealed. Receiver operating characteristic (ROC) curves were generated to determine the diagnostic value of histogram parameters. Significant differences were found in mean ADC-700, mean ADC-1500, skewness ADC-1500, and kurtosis ADC-1500 between bladder cancer and benign lesions (P = .002-.032). There were also significant differences in mean ADC-700, mean ADC-1500, and kurtosis ADC-1500 among bladder tumors of different pathologic T stages (P = .000-.046). No significant differences were observed in other parameters. Mean ADC-1500 and kurtosis ADC-1500 were significantly correlated with T stage, respectively (ρ = -0.614, P < .001; ρ = 0.374, P = .011). ROC analysis showed that the combination of mean ADC-1500 and kurtosis ADC-1500 has the maximal area under the ROC curve (AUC, 0.894; P < .001) in the differentiation of benign lesions and malignant tumors, with a sensitivity of 77.78% and specificity of 100%. AUCs for differentiating low- and high-stage tumors were 0.840 for mean ADC-1500 (P < .001) and 0.696 for kurtosis ADC-1500 (P = .015). Histogram analysis of ADC-1500 at 3.0 T can be useful in evaluation of bladder lesions. A combination of mean ADC-1500 and kurtosis ADC-1500 may be more beneficial in the differentiation of benign and malignant lesions. Mean ADC-1500 was the most promising parameter for differentiating low- from high-stage bladder cancer. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Liu, Wei; Wei, Tingcun; Li, Bo; Yang, Lifeng; Xue, Feifei; Hu, Yongcai
2016-05-01
This paper presents a 12-bit 1 MS/s successive approximation register-analog to digital converter (SAR-ADC) for the 32-channel front-end electronics of CZT-based PET imaging system. To reduce the capacitance mismatch, instead of the fractional capacitor, the unit capacitor is used as the bridge capacitor in the split-capacitor digital to analog converter (DAC) circuit. In addition, in order to eliminate the periodical DNL errors of -1 LSB which often exists in the SAR-ADC using the charge-redistributed DAC, a calibration algorithm is proposed and verified by the experiments. The proposed 12-bit 1 MS/s SAR-ADC is designed and implemented using a 0.35 μm CMOS technology, it occupies only an active area of 986×956 μm2. The measurement results show that, at the power supply of 3.3/5.0 V and the sampling rate of 1 MS/s, the ADC with calibration has a signal-to-noise-and-distortion ratio (SINAD) of 67.98 dB, the power dissipation of 5 mW, and a figure of merit (FOM) of 2.44 pJ/conv.-step. This ADC is with the features of high accuracy, low power and small layout area, it is especially suitable to the one-chip integration of the front-end readout electronics.
NASA Astrophysics Data System (ADS)
Mester, Dávid; Nagy, Péter R.; Kállay, Mihály
2018-03-01
A reduced-cost implementation of the second-order algebraic-diagrammatic construction [ADC(2)] method is presented. We introduce approximations by restricting virtual natural orbitals and natural auxiliary functions, which results, on average, in more than an order of magnitude speedup compared to conventional, density-fitting ADC(2) algorithms. The present scheme is the successor of our previous approach [D. Mester, P. R. Nagy, and M. Kállay, J. Chem. Phys. 146, 194102 (2017)], which has been successfully applied to obtain singlet excitation energies with the linear-response second-order coupled-cluster singles and doubles model. Here we report further methodological improvements and the extension of the method to compute singlet and triplet ADC(2) excitation energies and transition moments. The various approximations are carefully benchmarked, and conservative truncation thresholds are selected which guarantee errors much smaller than the intrinsic error of the ADC(2) method. Using the canonical values as reference, we find that the mean absolute error for both singlet and triplet ADC(2) excitation energies is 0.02 eV, while that for oscillator strengths is 0.001 a.u. The rigorous cutoff parameters together with the significantly reduced operation count and storage requirements allow us to obtain accurate ADC(2) excitation energies and transition properties using triple-ζ basis sets for systems of up to one hundred atoms.
Cho, Seung Hyun; Kim, Gab Chul; Jang, Yun-Jin; Ryeom, Hunkyu; Kim, Hye Jung; Shin, Kyung-Min; Park, Jun Seok; Choi, Gyu-Seog; Kim, See Hyung
2015-09-01
The value of diffusion-weighted imaging (DWI) for reliable differentiation between pathologic complete response (pCR) and residual tumor is still unclear. Recently, a few studies reported that histogram analysis can be helpful to monitor the therapeutic response in various cancer research. To investigate whether post-chemoradiotherapy (CRT) apparent diffusion coefficient (ADC) histogram analysis can be helpful to predict a pCR in locally advanced rectal cancer (LARC). Fifty patients who underwent preoperative CRT followed by surgery were enrolled in this retrospective study, non-pCR (n = 41) and pCR (n = 9), respectively. ADC histogram analysis encompassing the whole tumor was performed on two post-CRT ADC600 and ADC1000 (b factors 0, 600 vs. 0, 1000 s/mm(2)) maps. Mean, minimum, maximum, SD, mode, 10th, 25th, 50th, 75th, 90th percentile ADCs, skewness, and kurtosis were derived. Diagnostic performance for predicting pCR was evaluated and compared. On both maps, 10th and 25th ADCs showed better diagnostic performance than that using mean ADC. Tenth percentile ADCs revealed the best diagnostic performance on both ADC600 (AZ 0.841, sensitivity 100%, specificity 70.7%) and ADC1000 (AZ 0.821, sensitivity 77.8%, specificity 87.8%) maps. In comparison between 10th percentile and mean ADC, the specificity was significantly improved on both ADC600 (70.7% vs. 53.7%; P = 0.031) and ADC1000 (87.8% vs. 73.2%; P = 0.039) maps. Post-CRT ADC histogram analysis is helpful for predicting pCR in LARC, especially, in improving the specificity, compared with mean ADC. © The Foundation Acta Radiologica 2014.
Koczor, Bálint; Rohonczy, János
2015-01-01
Concerning many former liquid or hybrid liquid/solid NMR consoles, the built in Analog-to-Digital Converters (ADCs) are incapable of digitizing the fids at sampling rates in the MHz range. Regarding both strong anisotropic interactions in the solid state and wide chemical shift dispersion nuclei in solution phase such as (195)Pt, (119)Sn, (207)Pb etc., the spectrum range of interest might be in the MHz range. As determining the informative tensor components of anisotropic NMR interactions requires nonlinear fitting over the whole spectrum including the asymptotic baseline, it is prohibited by low sampling rates of the ADCs. Wide spectrum width is also useful in solution NMR, since windowing of wide chemical shift ranges is avoidable. We built an external analog to digital converter with 10 MHz maximal sampling rate, which can work simultaneously with the built in ADC of the spectrometer. The ADC was tested on both Bruker DRX and Avance-I NMR consoles. In addition to the analog channels it only requires three external digital lines of the NMR console. The ADC sends data to PC via USB. The whole process is controlled by software written in JAVA which is implemented under TopSpin. Copyright © 2015 Elsevier Inc. All rights reserved.
A research of a high precision multichannel data acquisition system
NASA Astrophysics Data System (ADS)
Zhong, Ling-na; Tang, Xiao-ping; Yan, Wei
2013-08-01
The output signals of the focusing system in lithography are analog. To convert the analog signals into digital ones which are more flexible and stable to process, a desirable data acquisition system is required. The resolution of data acquisition, to some extent, affects the accuracy of focusing. In this article, we first compared performance between the various kinds of analog-to-digital converters (ADC) available on the market at the moment. Combined with the specific requirements (sampling frequency, converting accuracy, numbers of channels etc) and the characteristics (polarization, amplitude range etc) of the analog signals, the model of the ADC to be used as the core chip in our hardware design was determined. On this basis, we chose other chips needed in the hardware circuit that would well match with ADC, then the overall hardware design was obtained. Validation of our data acquisition system was verified through experiments and it can be demonstrated that the system can effectively realize the high resolution conversion of the multi-channel analog signals and give the accurate focusing information in lithography.
Chan, Sheng-Chieh; Lin, Yu-Chun; Yen, Tzu-Chen; Liao, Chun-Ta; Chang, Joseph Tung-Chieh; Ko, Sheung-Fat; Wang, Hung- Ming; Chang, Chee-Jen; Wang, Jiun-Jie
2014-01-01
The clinical usefulness of pretreatment imaging techniques for predicting neck control in patients with oropharyngeal or hypopharyngeal squamous cell carcinoma (OHSCC) treated with chemoradiation remains unclear. In this prospective study, we investigated the role of pretreatment dynamic contrast-enhanced perfusion MR imaging (DCE-PWI), diffusion-weighted MR imaging (DWI), and [18F]fluorodeoxyglucose-positron emission tomography (18F-FDG PET)/CT derived imaging markers for the prediction of neck control in OHSCC patients treated with chemoradiation. Patients with untreated OHSCC scheduled for chemoradiation between August, 2010 and July, 2012 were eligible for the study. Clinical variables and the following imaging parameters of metastatic neck lymph nodes were examined in relation to neck control: transfer constant, volume of blood plasma, and volume of extracellular extravascular space (Ve) on DCE-PWI; apparent diffusion coefficient (ADC) on DWI; maximum standardized uptake value, metabolic tumor volume, and total lesion glycolysis on 18F-FDG PET/CT. There were 69 patients (37 with oropharynx SCC and 32 with hypopharynx SCC) with successful pretreatment DCE-PWI and DWI available for analysis. After a median follow-up of 31 months, 25 (36.2%) participants had neck failure. Multivariate analysis identified hemoglobin level <14.3 g/dL (P = 0.019), Ve <0.23 (P = 0.040), and ADC >1.14×10−3 mm2/s (P = 0.003) as independent prognostic factors for 3-year neck control. A prognostic scoring system was formulated by summing up the three significant predictors of neck control. Patients with scores of 2–3 had significantly poorer neck control and overall survival rates than patients with scores of 0–1. We conclude that hemoglobin levels, Ve, and ADC are independent pretreatment prognostic factors for neck control in OHSCC treated with chemoradiation. Their combination may identify a subgroup of patients at high risk of developing neck failure. PMID:25531391
Correlation of apparent diffusion coefficient ratio on 3.0 T MRI with prostate cancer Gleason score.
Jyoti, Rajeev; Jain, Tarun Pankaj; Haxhimolla, Hodo; Liddell, Heath; Barrett, Sean Edward
2018-01-01
The purpose was to investigate the usefulness of ADC ratio on Diffusion MRI to discriminate between benign and malignant lesions of Prostate. Images of patients who underwent in-gantry MRI guided prostate lesion biopsy were retrospectively analyzed. Prostate Cancers with 20% or more Gleason score (GS) pattern 3 + 3 = 6 in each core or any volume of higher Gleason score pattern were included. ADC ratio was calculated by two reviewers for each lesion. The ADC ratio was calculated for each lesion by dividing the lowest ADC value in a lesion and highest ADC value in normal prostate in peripheral zone (PZ). ADC ratio values were compared with the biopsy result. Data was analysed using independent samples T-test, Spearman correlation, intra-class correlation coefficient (ICC) and Receiver operating characteristic (ROC) curve. 45 lesions in 33 patients were analyzed. 12 lesions were in transitional zone (TZ) and 33 in perpheral zone PZ. All lesions demonstrated an ADC ratio of 0.45 or lower. GS demonstrated a negative correlation with both the ADC value and ADC ratio . However, ADC ratio (p < 0.001) demonstrated a stronger correlation compared to ADC value alone (p = 0.014). There was no significant statistical difference between GS 3 + 4 and GS 4 + 3 mean ADC tumour value (p = 0.167). However when using ADC ratio , there was a significant difference (p = 0.032). ROC curve analysis demonstrated an area under the curve of 0.83 using ADC ratio and 0.76 when using ADC tumour value when discriminating Gleason 6 from Gleason ≥7 tumours. Inter-observer reliability in the calculation of ADC ratios was excellent, with ICC of 0.964. ADC ratio is a reliable and reproducible tool in quantification of diffusion restriction for clinically significant prostate cancer foci.
Diffusion-weighted magnetic resonance imaging in autoimmune pancreatitis.
Taniguchi, Takao; Kobayashi, Hisato; Nishikawa, Koji; Iida, Etsushi; Michigami, Yoshihiro; Morimoto, Emiko; Yamashita, Rikiya; Miyagi, Ken; Okamoto, Motozumi
2009-04-01
The aim of this study was to investigate the usefulness of diffusion-weighted magnetic resonance imaging (DWI MRI) for the diagnosis and evaluation of autoimmune pancreatitis (AIP). A total of 4 consecutive patients with AIP, 5 patients with chronic alcoholic pancreatitis (CP), and 13 patients without pancreatic disease (controls) were studied. DWI was performed in the axial plane with spin-echo echo-planar imaging single-shot sequence. Apparent diffusion coefficients (ADCs) were measured in circular regions of interest in the pancreas. In AIP patients, abdominal MRI was performed before, and 2-4 weeks after steroid treatment. Follow-up study was performed chronologically for up to 11 months in two patients. The correlation between ADCs of the pancreas and the immunoglobulin G4 (IgG4) index (serum IgG4 value/serum IgG4 value before steroid treatment) was evaluated. In the AIP patients, DWI of the pancreas showed high signal intensity, and the ADCs of the pancreas (mean +/- SD: 0.97 +/- 0.18 x 10(-3) mm(2)/s) were significantly lower than those in patients with CP (1.45 +/- 0.10 x 10(-3) mm(2)/s) or the controls (1.45 +/- 0.16 x 10(-3) mm(2)/s) (Mann-Whitney U-test, P < 0.05). In one AIP patient with focal swelling of the pancreas head that appeared to be a mass, DWI showed high signal intensity throughout the pancreas, indicating diffuse involvement. The ADCs of the pancreas and IgG4 index were significantly inversely correlated (Spearman's rank correlation coefficient, r (s) = -0.80, P < 0.05). Autoimmune pancreatitis showed high signal intensity on DWI, which improved after steroid treatment. ADCs reflected disease activity. Thus, diffusion-weighted MRI might be useful for diagnosing AIP, determining the affected area, and evaluating the effect of treatment.
Dorywalska, Magdalena; Dushin, Russell; Moine, Ludivine; Farias, Santiago E; Zhou, Dahui; Navaratnam, Thayalan; Lui, Victor; Hasa-Moreno, Adela; Casas, Meritxell Galindo; Tran, Thomas-Toan; Delaria, Kathy; Liu, Shu-Hui; Foletti, Davide; O'Donnell, Christopher J; Pons, Jaume; Shelton, David L; Rajpal, Arvind; Strop, Pavel
2016-05-01
The degree of stability of antibody-drug linkers in systemic circulation, and the rate of their intracellular processing within target cancer cells are among the key factors determining the efficacy of antibody-drug conjugates (ADC) in vivo Previous studies demonstrated the susceptibility of cleavable linkers, as well as auristatin-based payloads, to enzymatic cleavage in rodent plasma. Here, we identify Carboxylesterase 1C as the enzyme responsible for the extracellular hydrolysis of valine-citrulline-p-aminocarbamate (VC-PABC)-based linkers in mouse plasma. We further show that the activity of Carboxylesterase 1C towards VC-PABC-based linkers, and consequently the stability of ADCs in mouse plasma, can be effectively modulated by small chemical modifications to the linker. While the introduced modifications can protect the VC-PABC-based linkers from extracellular cleavage, they do not significantly alter the intracellular linker processing by the lysosomal protease Cathepsin B. The distinct substrate preference of the serum Carboxylesterase 1C offers the opportunity to modulate the extracellular stability of cleavable ADCs without diminishing the intracellular payload release required for ADC efficacy. Mol Cancer Ther; 15(5); 958-70. ©2016 AACR. ©2016 American Association for Cancer Research.
Kitahara, Sawako; Nakasu, Satoshi; Murata, Kiyoshi; Sho, Keizen; Ito, Ryuta
2005-10-01
Treatment with chemotherapy and radiation therapy for brain tumors can cause white matter (WM) injury. Conventional MR imaging, however, cannot always depict treatment-induced transient WM abnormalities. We investigated the ability of diffusion-tensor (DT) MR imaging and proton MR spectroscopy to detect the treatment-induced transient changes within normal-appearing WM. DT MR imaging and proton MR spectroscopy were performed in 8 patients treated with a combination of surgery, chemotherapy, and radiation therapy for brain tumors (17 examinations) and 11 age-matched controls. Apparent diffusion coefficient (ADC) value, fractional anisotropy (FA) value, and N-acetylaspartate (NAA)/creatine (Cr) ratio were obtained from 27 hemispheres with normal-appearing WM in the patients. We divided the datasets of isotropic ADC, FA, and NAA/Cr, on the basis of the time period after completion of radiation therapy, into 4 groups: group 1 (0-2 months; n = 10), group 2 (3-5 months; n = 5), group 3 (6-9 months; n = 7), and group 4 (10-12 months; n = 5). We compared averages of mean isotropic ADC, mean FA, and NAA/Cr of each patient group with those of the control group by using a t test. In the group 2, averages of mean FA and NAA/Cr decreased and average of mean isotopic ADC increased in comparison with those of the control group (P = .004, .04, and .0085, respectively). There were no significant differences in the averages between the control group and patient groups 1, 3, and 4. DT MR imaging and proton MR spectroscopy can provide quantitative indices that may reflect treatment-induced transient derangement of normal-appearing WM.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Y; Yin, F; Czito, B
2015-06-15
Purpose: Diffusion-weighted imaging(DWI) has been shown to have superior tumor-to-tissue contrast for cancer detection.This study aims at developing and evaluating a four dimensional DWI(4D-DWI) technique using retrospective sorting method for imaging respiratory motion for radiotherapy planning,and evaluate its effect on Apparent Diffusion Coefficient(ADC) measurement. Materials/Methods: Image acquisition was performed by repeatedly imaging a volume of interest using a multi-slice single-shot 2D-DWI sequence in the axial planes and cine MRI(served as reference) using FIESTA sequence.Each 2D-DWI image were acquired in xyz-diffusion-directions with a high b-value(b=500s/mm2).The respiratory motion was simultaneously recorded using bellows.Retrospective sorting was applied in each direction to reconstruct 4D-DWI.Themore » technique was evaluated using a computer simulated 4D-digital human phantom(XCAT),a motion phantom and a healthy volunteer under an IRB-approved study.Motion trajectories of regions-of-interests(ROI) were extracted from 4D-DWI and compared with reference.The mean motion trajectory amplitude differences(D) between the two was calculated.To quantitatively analyze the motion artifacts,XCAT were controlled to simulate regular motion and the motions of 10 liver cancer patients.4D-DWI,free-breathing DWI(FB- DWI) were reconstructed.Tumor volume difference(VD) of each phase of 4D-DWI and FB-DWI from the input static tumor were calculated.Furthermore, ADC was measured for each phase of 4D-DWI and FB-DWI data,and mean tumor ADC values(M-ADC) were calculated.Mean M-ADC over all 4D-DWI phases was compared with M-ADC calculated from FB-DWI. Results: 4D-DWI of XCAT,the motion phantom and the healthy volunteer demonstrated the respiratory motion clearly.ROI D values were 1.9mm,1.7mm and 2.0mm,respectively.For motion artifacts analysis,XCAT 4D-DWI images show much less motion artifacts compare to FB-DWI.Mean VD for 4D-WDI and FB-DWI were 8.5±1.4% and 108±15%,respectively.Mean M-ADC for ADC measured from 4D-DWI and M-ADC measured from FB-DWI were (2.29±0.04)*0.001*mm2/s and (3.80±0.01)*0.001*mm2/s,respectively.ADC value ground-truth is 2.24*0.001*mm2/s from the input of the simulation. Conclusion: A respiratory correlated 4D-DWI technique has been initially evaluated in phantoms and a human subject.Comparing to free breathing DWI,4D-DWI can lead to more accurate measurement of ADC.« less
Hao, Yonghong; Pan, Chu; Chen, WeiWei; Li, Tao; Zhu, WenZhen; Qi, JianPin
2016-12-01
To explore the usefulness of whole-lesion histogram analysis of apparent diffusion coefficient (ADC) derived from reduced field-of-view (r-FOV) diffusion-weighted imaging (DWI) in differentiating malignant and benign thyroid nodules and stratifying papillary thyroid cancer (PTC) with aggressive histological features. This Institutional Review Board-approved, retrospective study included 93 patients with 101 pathologically proven thyroid nodules. All patients underwent preoperative r-FOV DWI at 3T. The whole-lesion ADC assessments were performed for each patient. Histogram-derived ADC parameters between different subgroups (pathologic type, extrathyroidal extension, lymph node metastasis) were compared. Receiver operating characteristic curve analysis was used to determine optimal histogram parameters in differentiating benign and malignant nodules and predicting aggressiveness of PTC. Mean ADC, median ADC, 5 th percentile ADC, 25 th percentile ADC, 75 th percentile ADC, 95 th percentile ADC (all P < 0.001), and kurtosis (P = 0.001) were significantly lower in malignant thyroid nodules, and mean ADC achieved the highest AUC (0.919) with a cutoff value of 1842.78 × 10 -6 mm 2 /s in differentiating malignant and benign nodules. Compared to the PTCs without extrathyroidal extension, PTCs with extrathyroidal extension showed significantly lower median ADC, 5 th percentile ADC, and 25 th percentile ADC. The 5 th percentile ADC achieved the highest AUC (0.757) with cutoff value of 911.5 × 10 -6 mm 2 /s for differentiating between PTCs with and without extrathyroidal extension. Whole-lesion ADC histogram analysis might help to differentiate malignant nodules from benign ones and show the PTCs with extrathyroidal extension. J. Magn. Reson. Imaging 2016;44:1546-1555. © 2016 International Society for Magnetic Resonance in Medicine.
PCI/iRMX-Based Front-End Data Acquisition for the HT-7U Experiment
NASA Astrophysics Data System (ADS)
Shu, Yantai; Luo, Jiarong; Yan, Jianbing; Zhao, Feng; Zhang, Liang
2004-06-01
A PCI/iRMX-based front-end system is being designed to serve as data acquisition (DAQ) subsystem for the HT-7U superconducting tokamak. The diagnostic instruments are connected to four analog-to-digital converter (ADC) boards that are directly plugged into the peripheral component interconnect (PCI) bus of a personal computer (PC) running the iRMX real-time operating system. Each ADC board has eight channels. The sampling rate of each channel can be up to 125 K samples per second. The acquired data are directly transferred from the ADC board into the memory of the PC, and then transferred to servers through the network. As a testbed, one PCI/iRMX subsystem has been built and has acquired data from the existing HT-7 tokamak. The DAQ can easily support a wide range of pulse lengths, even matching extremely long pulse and steady-state operation. This paper describes the system design and performance evaluation in detail.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lefrancois, Daniel; Dreuw, Andreas, E-mail: dreuw@uni-heidelberg.de; Rehn, Dirk R.
For the calculation of adiabatic singlet-triplet gaps (STG) in diradicaloid systems the spin-flip (SF) variant of the algebraic diagrammatic construction (ADC) scheme for the polarization propagator in third order perturbation theory (SF-ADC(3)) has been applied. Due to the methodology of the SF approach the singlet and triplet states are treated on an equal footing since they are part of the same determinant subspace. This leads to a systematically more accurate description of, e.g., diradicaloid systems than with the corresponding non-SF single-reference methods. Furthermore, using analytical excited state gradients at ADC(3) level, geometry optimizations of the singlet and triplet states weremore » performed leading to a fully consistent description of the systems, leading to only small errors in the calculated STGs ranging between 0.6 and 2.4 kcal/mol with respect to experimental references.« less
Guo, Jianxin; Kumar, Sandeep; Prashad, Amarnauth; Starkey, Jason; Singh, Satish K
2014-07-01
To provide a systematic biophysical approach towards a better understanding of impact of conjugation chemistry on higher order structure and physical stability of an antibody drug conjugate (ADC). ADC was prepared using thiol-maleimide chemistry. Physical stabilities of ADC and its parent IgG1 mAb were compared using calorimetric, spectroscopic and molecular modeling techniques. ADC and mAb respond differently to thermal stress. Both the melting temperatures and heat capacities are substantially lower for the ADC. Spectroscopic experiments show that ADC and mAb have similar secondary and tertiary structures, but these are more easily destabilized by thermal stress on the ADC indicating reduced conformational stability. Molecular modeling calculations suggest a substantial decrease in the conformational energy of the mAb upon conjugation. The local surface around the conjugation sites also becomes more hydrophobic in the ADC, explaining the lower colloidal stability and greater tendency of the ADC to aggregate. Computational and biophysical analyses of an ADC and its parent mAb have provided insights into impact of conjugation on physical stability and pinpointed reasons behind lower structural stability and increased aggregation propensity of the ADC. This knowledge can be used to design appropriate formulations to stabilize the ADC.
Bao, Shixing; Watanabe, Yoshiyuki; Takahashi, Hiroto; Tanaka, Hisashi; Arisawa, Atsuko; Matsuo, Chisato; Wu, Rongli; Fujimoto, Yasunori; Tomiyama, Noriyuki
2018-05-31
This study aimed to determine whether whole-tumor histogram analysis of normalized cerebral blood volume (nCBV) and apparent diffusion coefficient (ADC) for contrast-enhancing lesions can be used to differentiate between glioblastoma (GBM) and primary central nervous system lymphoma (PCNSL). From 20 patients, 9 with PCNSL and 11 with GBM without any hemorrhagic lesions, underwent MRI, including diffusion-weighted imaging and dynamic susceptibility contrast perfusion-weighted imaging before surgery. Histogram analysis of nCBV and ADC from whole-tumor voxels in contrast-enhancing lesions was performed. An unpaired t-test was used to compare the mean values for each type of tumor. A multivariate logistic regression model (LRM) was performed to classify GBM and PCNSL using the best parameters of ADC and nCBV. All nCBV histogram parameters of GBMs were larger than those of PCNSLs, but only average nCBV was statistically significant after Bonferroni correction. Meanwhile, ADC histogram parameters were also larger in GBM compared to those in PCNSL, but these differences were not statistically significant. According to receiver operating characteristic curve analysis, the nCBV average and ADC 25th percentile demonstrated the largest area under the curve with values of 0.869 and 0.838, respectively. The LRM combining these two parameters differentiated between GBM and PCNSL with a higher area under the curve value (Logit (P) = -21.12 + 10.00 × ADC 25th percentile (10 -3 mm 2 /s) + 5.420 × nCBV mean, P < 0.001). Our results suggest that whole-tumor histogram analysis of nCBV and ADC combined can be a valuable objective diagnostic method for differentiating between GBM and PCNSL.
Aliotta, Eric; Moulin, Kévin; Zhang, Zhaohuan; Ennis, Daniel B.
2018-01-01
Purpose To evaluate a technique for simultaneous quantitative T2 and apparent diffusion coefficient (ADC) mapping in the heart (T2+ADC) using spin echo (SE) diffusion-weighted imaging (DWI). Theory and Methods T2 maps from T2+ADC were compared with single-echo SE in phantoms and with T2-prepared (T2-prep) balanced steady-state free precession (bSSFP) in healthy volunteers. ADC maps from T2+ADC were compared with conventional DWI in phantoms and in vivo. T2+ADC was also demonstrated in a patient with acute myocardial infarction (MI). Results Phantom T2 values from T2+ADC were closer to a single-echo SE reference than T2-prep bSSFP (−2.3 ± 6.0% vs 22.2 ± 16.3%; P < 0.01), and ADC values were in excellent agreement with DWI (0.28 ± 0.4%). In volunteers, myocardial T2 values from T2+ADC were significantly shorter than T2-prep bSSFP (35.8 ± 3.1 vs 46.8 ± 3.8 ms; P < 0.01); myocardial ADC was not significantly (N.S.) different between T2+ADC and conventional motion-compensated DWI (1.39 ± 0.18 vs 1.38 ± 0.18 mm2/ms; P = N.S.). In the patient, T2 and ADC were both significantly elevated in the infarct compared with remote myocardium (T2: 40.4 ± 7.6 vs 56.8 ± 22.0; P < 0.01; ADC: 1.47 ± 0.59 vs 1.65 ± 0.65 mm2/ms; P < 0.01). Conclusion T2+ADC generated coregistered, free-breathing T2 and ADC maps in healthy volunteers and a patient with acute MI with no cost in accuracy, precision, or scan time compared with DWI. PMID:28516485
Umanodan, Tomokazu; Fukukura, Yoshihiko; Kumagae, Yuichi; Shindo, Toshikazu; Nakajo, Masatoyo; Takumi, Koji; Nakajo, Masanori; Hakamada, Hiroto; Umanodan, Aya; Yoshiura, Takashi
2017-04-01
To determine the diagnostic performance of apparent diffusion coefficient (ADC) histogram analysis in diffusion-weighted (DW) magnetic resonance imaging (MRI) for differentiating adrenal adenoma from pheochromocytoma. We retrospectively evaluated 52 adrenal tumors (39 adenomas and 13 pheochromocytomas) in 47 patients (21 men, 26 women; mean age, 59.3 years; range, 16-86 years) who underwent DW 3.0T MRI. Histogram parameters of ADC (b-values of 0 and 200 [ADC 200 ], 0 and 400 [ADC 400 ], and 0 and 800 s/mm 2 [ADC 800 ])-mean, variance, coefficient of variation (CV), kurtosis, skewness, and entropy-were compared between adrenal adenomas and pheochromocytomas, using the Mann-Whitney U-test. Receiver operating characteristic (ROC) curves for the histogram parameters were generated to differentiate adrenal adenomas from pheochromocytomas. Sensitivity and specificity were calculated by using a threshold criterion that would maximize the average of sensitivity and specificity. Variance and CV of ADC 800 were significantly higher in pheochromocytomas than in adrenal adenomas (P < 0.001 and P = 0.001, respectively). With all b-value combinations, the entropy of ADC was significantly higher in pheochromocytomas than in adrenal adenomas (all P ≤ 0.001), and showed the highest area under the ROC curve among the ADC histogram parameters for diagnosing adrenal adenomas (ADC 200 , 0.82; ADC 400 , 0.87; and ADC 800 , 0.92), with sensitivity of 84.6% and specificity of 84.6% (cutoff, ≤2.82) with ADC 200 ; sensitivity of 89.7% and specificity of 84.6% (cutoff, ≤2.77) with ADC 400 ; and sensitivity of 94.9% and specificity of 92.3% (cutoff, ≤2.67) with ADC 800 . ADC histogram analysis of DW MRI can help differentiate adrenal adenoma from pheochromocytoma. 3 J. Magn. Reson. Imaging 2017;45:1195-1203. © 2016 International Society for Magnetic Resonance in Medicine.
Koral, Korgün; Mathis, Derek; Gimi, Barjor; Gargan, Lynn; Weprin, Bradley; Bowers, Daniel C; Margraf, Linda
2013-08-01
To test whether there is correlation between cell densities and apparent diffusion coefficient (ADC) metrics of common pediatric cerebellar tumors. This study was reviewed for issues of patient safety and confidentiality and was approved by the Institutional Review Board of the University of Texas Southwestern Medical Center and was compliant with HIPAA. The need for informed consent was waived. Ninety-five patients who had preoperative magnetic resonance imaging and surgical pathologic findings available between January 2003 and June 2011 were included. There were 37 pilocytic astrocytomas, 34 medulloblastomas (23 classic, eight desmoplastic-nodular, two large cell, one anaplastic), 17 ependymomas (13 World Health Organization [WHO] grade II, four WHO grade III), and seven atypical teratoid rhabdoid tumors. ADCs of solid tumor components and normal cerebellum were measured. Tumor-to-normal brain ADC ratios (hereafter, ADC ratio) were calculated. The medulloblastomas and ependymomas were subcategorized according to the latest WHO classification, and tumor cellularity was calculated. Correlation was sought between cell densities and mean tumor ADCs, minimum tumor ADCs, and ADC ratio. When all tumors were considered together, negative correlation was found between cellularity and mean tumor ADCs (ρ = -0.737, P < .05) and minimum tumor ADCs (ρ = -0.736, P < .05) of common pediatric cerebellar tumors. There was no correlation between cellularity and ADC ratio. Negative correlation was found between cellularity and minimum tumor ADC in atypical teratoid rhabdoid tumors (ρ = -0.786, P < .05). In atypical teratoid rhabdoid tumors, no correlation was found between cellularity and mean tumor ADC and ADC ratio. There was no correlation between the ADC metrics and cellularity of the pilocytic astrocytomas, medulloblastomas, and ependymomas. Negative correlation was found between cellularity and ADC metrics of common pediatric cerebellar tumors. Although ADC metrics are useful in the preoperative diagnosis of common pediatric cerebellar tumors and this utility is generally attributed to differences in cellularity of tumors, tumor cellularity may not be the sole determinant of the differences in diffusivity.
Development of radiation tolerant components for the Quench Protection System at CERN
NASA Astrophysics Data System (ADS)
Bitterling, O.; Denz, R.; Steckert, J.; Uznanski, S.
2016-01-01
This paper describes the results of irradiation campaigns with the high resolution Analog to Digital Converter (ADC) ADS1281. This ADC will be used as part of a revised quench detection circuit for the 600 A corrector magnets at the CERN Large Hadron Collider (LHC) . To verify the radiation tolerance of the ADC an irradiation campaign using a proton beam, applying doses up to 3,4 kGy was conducted. The resulting data and an analysis of the found failure modes is discussed in this paper. Several mitigation measures are described that allow to reduce the error rate to levels acceptable for operation as part of the LHC QPS.
Gotti, Daria; Raffetti, Elena; Albini, Laura; Sighinolfi, Laura; Maggiolo, Franco; Di Filippo, Elisa; Ladisa, Nicoletta; Angarano, Gioacchino; Lapadula, Giuseppe; Pan, Angelo; Esposti, Anna Degli; Fabbiani, Massimiliano; Focà, Emanuele; Scalzini, Alfredo; Donato, Francesco; Quiros-Roldan, Eugenia
2014-01-01
We studied survival and associated risk factors in an Italian nationwide cohort of HIV-infected individuals after an AIDS-defining cancer (ADC) or non-AIDS-defining cancer (NADC) diagnosis in the modern cART era. Multi-center, retrospective, observational study of HIV patients included in the MASTER Italian Cohort with a cancer diagnosis from January 1998 to September 2012. Malignancies were divided into ADC or NADC on the basis of the Centre for Disease Control-1993 classification. Recurrence of cancer and metastases were excluded. Survivals were estimated according to the Kaplan-Meier method and compared according to the log-rank test. Statistically significant variables at univariate analysis were entered in a multivariate Cox regression model. Eight hundred and sixty-six cancer diagnoses were recorded among 13,388 subjects in the MASTER Database after 1998: 435 (51%) were ADCs and 431 (49%) were NADCs. Survival was more favorable after an ADC diagnosis than a NADC diagnosis (10-year survival: 62.7%±2.9% vs. 46%±4.2%; p = 0.017). Non-Hodgkin lymphoma had lower survival rates than patients with Kaposi sarcoma or cervical cancer (10-year survival: 48.2%±4.3% vs. 72.8%±4.0% vs. 78.5%±9.9%; p<0.001). Regarding NADCs, breast cancer showed better survival (10-year survival: 65.1%±14%) than lung cancer (1-year survival: 28%±8.7%), liver cancer (5-year survival: 31.9%±6.4%) or Hodgkin lymphoma (10-year survival: 24.8%±11.2%). Lower CD4+ count and intravenous drug use were significantly associated with decreased survival after ADCs or NADCs diagnosis. Exposure to cART was found to be associated with prolonged survival only in the case of ADCs. cART has improved survival in patients with an ADC diagnosis, whereas the prognosis after a diagnosis of NADCs is poor. Low CD4+ counts and intravenous drug use are risk factors for survival following a diagnosis of ADCs and Hodgkin lymphoma in the NADC group.
Gotti, Daria; Raffetti, Elena; Albini, Laura; Sighinolfi, Laura; Maggiolo, Franco; Di Filippo, Elisa; Ladisa, Nicoletta; Angarano, Gioacchino; Lapadula, Giuseppe; Pan, Angelo; Esposti, Anna Degli; Fabbiani, Massimiliano; Focà, Emanuele; Scalzini, Alfredo; Donato, Francesco; Quiros-Roldan, Eugenia
2014-01-01
Objectives We studied survival and associated risk factors in an Italian nationwide cohort of HIV-infected individuals after an AIDS-defining cancer (ADC) or non-AIDS-defining cancer (NADC) diagnosis in the modern cART era. Methods Multi-center, retrospective, observational study of HIV patients included in the MASTER Italian Cohort with a cancer diagnosis from January 1998 to September 2012. Malignancies were divided into ADC or NADC on the basis of the Centre for Disease Control-1993 classification. Recurrence of cancer and metastases were excluded. Survivals were estimated according to the Kaplan-Meier method and compared according to the log-rank test. Statistically significant variables at univariate analysis were entered in a multivariate Cox regression model. Results Eight hundred and sixty-six cancer diagnoses were recorded among 13,388 subjects in the MASTER Database after 1998: 435 (51%) were ADCs and 431 (49%) were NADCs. Survival was more favorable after an ADC diagnosis than a NADC diagnosis (10-year survival: 62.7%±2.9% vs. 46%±4.2%; p = 0.017). Non-Hodgkin lymphoma had lower survival rates than patients with Kaposi sarcoma or cervical cancer (10-year survival: 48.2%±4.3% vs. 72.8%±4.0% vs. 78.5%±9.9%; p<0.001). Regarding NADCs, breast cancer showed better survival (10-year survival: 65.1%±14%) than lung cancer (1-year survival: 28%±8.7%), liver cancer (5-year survival: 31.9%±6.4%) or Hodgkin lymphoma (10-year survival: 24.8%±11.2%). Lower CD4+ count and intravenous drug use were significantly associated with decreased survival after ADCs or NADCs diagnosis. Exposure to cART was found to be associated with prolonged survival only in the case of ADCs. Conclusions cART has improved survival in patients with an ADC diagnosis, whereas the prognosis after a diagnosis of NADCs is poor. Low CD4+ counts and intravenous drug use are risk factors for survival following a diagnosis of ADCs and Hodgkin lymphoma in the NADC group. PMID:24760049
Method and Apparatus for Improving the Resolution of Digitally Sampled Analog Data
NASA Technical Reports Server (NTRS)
Liaghati, Amir L. (Inventor)
2017-01-01
A system and method is described for converting an analog signal into a digital signal. The gain and offset of an ADC is dynamically adjusted so that the N-bits of input data are assigned to a narrower channel instead of the entire input range of the ADC. This provides greater resolution in the range of interest without generating longer digital data strings.
Two-step single slope/SAR ADC with error correction for CMOS image sensor.
Tang, Fang; Bermak, Amine; Amira, Abbes; Amor Benammar, Mohieddine; He, Debiao; Zhao, Xiaojin
2014-01-01
Conventional two-step ADC for CMOS image sensor requires full resolution noise performance in the first stage single slope ADC, leading to high power consumption and large chip area. This paper presents an 11-bit two-step single slope/successive approximation register (SAR) ADC scheme for CMOS image sensor applications. The first stage single slope ADC generates a 3-bit data and 1 redundant bit. The redundant bit is combined with the following 8-bit SAR ADC output code using a proposed error correction algorithm. Instead of requiring full resolution noise performance, the first stage single slope circuit of the proposed ADC can tolerate up to 3.125% quantization noise. With the proposed error correction mechanism, the power consumption and chip area of the single slope ADC are significantly reduced. The prototype ADC is fabricated using 0.18 μ m CMOS technology. The chip area of the proposed ADC is 7 μ m × 500 μ m. The measurement results show that the energy efficiency figure-of-merit (FOM) of the proposed ADC core is only 125 pJ/sample under 1.4 V power supply and the chip area efficiency is 84 k μ m(2) · cycles/sample.
Han, Haiwei; Han, Chengkun; Wu, Xiurong; Zhong, Shan; Zhuang, Xiongjie; Tan, Guowei; Wu, Hua
2017-05-01
The purpose of this study was to determine the difference in discrimination between high- and low-grade supratentorial nonenhancing gliomas (HGGs and LGGs, respectively) when using apparent diffusion coefficient (ADC) values with high or standard b-value. Thirty-nine patients underwent conventional magnetic resonance imaging and diffusion-weighted imaging (DWI) with standard and high b-values (b = 1000 and 3000 s/mm 2 , respectively). Minimum, maximum, and mean ADC values (ADC MIN , ADC MAX , and ADC MEAN , respectively) were measured from ADC maps with both b-values. Receiver operating curve analysis was used to determine the cutoff ADC values for distinguishing between nonenhancing HGGs and LGGs. ADC MIN , ADC MAX , and ADC MEAN values for the nonenhancing HGGs were lower than those for LGGs. These differences were much larger when a high b-value was used (all P < 0.0001) than when a standard b-value was used (P = 0.0001, <0.0001, and <0.0001, respectively). Discriminant analysis indicated that the greatest likelihood for discriminating HGGs and LGGs when ADC MEAN was obtained with a high b-value, with cutoff value of 0.814 × 10 -3 mm 2 /s. ADC values obtained with a high b-value can be useful for grading and surgical management of nonenhancing HGGs and LGGs. The lowest degree of overlap was obtained when ADC MEAN was determined with a b-value of 3000 s/mm 2 .
Simultaneous Silencing of Two Arginine Decarboxylase Genes Alters Development in Arabidopsis
Sánchez-Rangel, Diana; Chávez-Martínez, Ana I.; Rodríguez-Hernández, Aída A.; Maruri-López, Israel; Urano, Kaoru; Shinozaki, Kazuo; Jiménez-Bremont, Juan F.
2016-01-01
Polyamines (PAs) are small aliphatic polycations that are found ubiquitously in all organisms. In plants, PAs are involved in diverse biological processes such as growth, development, and stress responses. In Arabidopsis thaliana, the arginine decarboxylase enzymes (ADC1 and 2) catalyze the first step of PA biosynthesis. For a better understanding of PA biological functions, mutants in PA biosynthesis have been generated; however, the double adc1/adc2 mutant is not viable in A. thaliana. In this study, we generated non-lethal A. thaliana lines through an artificial microRNA that simultaneously silenced the two ADC genes (amiR:ADC). The generated transgenic lines (amiR:ADC-L1 and -L2) showed reduced AtADC1 and AtADC2 transcript levels. For further analyses the amiR:ADC-L2 line was selected. We found that the amiR:ADC-L2 line showed a significant decrease of their PA levels. The co-silencing revealed a stunted growth in A. thaliana seedlings, plantlets and delay in its flowering rate; these phenotypes were reverted with PA treatment. In addition, amiR:ADC-L2 plants displayed two seed phenotypes, such as yellow and brownish seeds. The yellow mutant seeds were smaller than adc1, adc2 mutants and wild type seeds; however, the brownish were the smallest seeds with arrested embryos at the torpedo stage. These data reinforce the importance of PA homeostasis in the plant development processes. PMID:27014322
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Y; Cao, M; Kamrava, M
Purpose: Diffusion weighted MRI (DWI) is a promising imaging technique for early prediction of tumor response to radiation therapy. A recently proposed longitudinal DWI strategy using a Co-60 MRI guided RT system (MRIgRT) may bring functional MRI guided adaptive radiation therapy closer to clinical utility. We report our preliminary results of using this longitudinal DWI approach performed on the MRIgRT system for predicting the response of sarcoma patient to preop RT. Methods: Three sarcoma patients who underwent fractionated IMRT were recruited in this study. For all three patients DWI images were acquired immediately following his/her treatment. For each imaging session,more » ten slices were acquired interleaved with the b values covering the gross tumor volume (GTV). The diffusion images were processed to obtain the ADC maps using standard exponential fitting for each voxel. Regions of interest were drawn in the tumor on the diffusion images based on each patient’s clinical GTV contours. Each patient subsequently underwent surgery and the tumor necrosis score was available from standard pathology. The ADC values for each patient were compared to the necrosis scores to assess the predictive value of our longitudinal DWI for tumor response. Results: Each patient underwent 3 to 5 diffusion MRI scans depending on their treatment length. Patient 1 had a relatively unchanged ADC during the course of RT and a necrosis score of 30% at surgery. For patient 2, the mean ADC values decreased from 1.56 × 10-3 to 1.12 × 10-3 mm2/s and the patient’s necrosis score was less than 10%. Patient 3 had a slight increase in the ADC values from 0.59 × 10-3 to 0.71 × 10-3 mm2/s and patient’s necrosis score was 50%. Conclusion: Based on limited data from 3 patients, our longitudinal changes in tumor ADC assessed using the MRIgRT system correlated well with pathology results.« less
Salazar-Badillo, Fatima Berenice; Sánchez-Rangel, Diana; Becerra-Flora, Alicia; López-Gómez, Miguel; Nieto-Jacobo, Fernanda; Mendoza-Mendoza, Artemio; Jiménez-Bremont, Juan Francisco
2015-10-01
Plants are associated with a wide range of microorganisms throughout their life cycle, and some interactions result on plant benefits. Trichoderma species are plant beneficial fungi that enhance plant growth and development, contribute to plant nutrition and induce defense responses. Nevertheless, the molecules involved in these beneficial effects still need to be identify. Polyamines are ubiquitous molecules implicated in plant growth and development, and in the establishment of plant microbe interactions. In this study, we assessed the polyamine profile in Arabidopsis plants during the interaction with Trichoderma virens and Trichoderma atroviride, using a system that allows direct plant-fungal contact or avoids their physical interaction (split system). The plantlets that grew in the split system exhibited higher biomass than the ones in direct contact with Trichoderma species. After 3 days of interaction, a significant decrease in Arabidopsis polyamine levels was observed in both systems (direct contact and split). After 5 days of interaction polyamine levels were increased. The highest levels were observed with T. atroviride (split system), and with T. virens (direct contact). The expression levels of Arabidopsis ADC1 and ADC2 genes during the interaction with the fungi were also assessed. We observed a time dependent regulation of ADC1 and ADC2 genes, which correlates with polyamine levels. Our data show an evident change in polyamine profile during Arabidopsis - Trichoderma interaction, accompanied by evident alterations in plant root architecture. Polyamines could be involved in the changes undergone by plant during the interaction with this beneficial fungus. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Structural white matter changes in adolescents and young adults with maple syrup urine disease.
Klee, D; Thimm, E; Wittsack, H J; Schubert, D; Primke, R; Pentang, G; Schaper, J; Mödder, U; Antoch, A; Wendel, U; Cohnen, M
2013-11-01
To get insight into the nature of magnetic resonance (MR) white matter abnormalities of patients with classic maple syrup urine disease (MSUD) under diet control. Ten patients with classic MSUD and one with a severe MSUD variant (mean age 21.5 ± 5.1 years) on diet and 11 age and sex-matched healthy subjects were enrolled. Apart from standard MR sequences, diffusion weighted images (DWI), diffusion tensor images (DTI), and magnetization transfer images (MT) were obtained and comparatively analyzed for apparent diffusion coefficient (ADC), tensor fractional anisotropy (FA) and MT maps in 11 regions of interest (ROI) within the white matter. In MSUD patients DWI, DTI and FA showed distinct signal changes in the cerebral hemispheres, the dorsal limb of internal capsule, the brain stem and the central cerebellum. Signal intensity was increased in DWI with a reduced ADC and decreased values for FA. MT did not reveal differences between patients and control subjects. Signal abnormalities in the white matter of adolescents and young adults under diet control may be interpreted as consequence of structural alterations like dysmyelination. The reduced ADC and FA in the white matter with preserved MT indicate a reduction in fiber tracks.
Impact of post-processing methods on apparent diffusion coefficient values.
Zeilinger, Martin Georg; Lell, Michael; Baltzer, Pascal Andreas Thomas; Dörfler, Arnd; Uder, Michael; Dietzel, Matthias
2017-03-01
The apparent diffusion coefficient (ADC) is increasingly used as a quantitative biomarker in oncological imaging. ADC calculation is based on raw diffusion-weighted imaging (DWI) data, and multiple post-processing methods (PPMs) have been proposed for this purpose. We investigated whether PPM has an impact on final ADC values. Sixty-five lesions scanned with a standardized whole-body DWI-protocol at 3 T served as input data (EPI-DWI, b-values: 50, 400 and 800 s/mm 2 ). Using exactly the same ROI coordinates, four different PPM (ADC_1-ADC_4) were executed to calculate corresponding ADC values, given as [10 -3 mm 2 /s] of each lesion. Statistical analysis was performed to intra-individually compare ADC values stratified by PPM (Wilcoxon signed-rank tests: α = 1 %; descriptive statistics; relative difference/∆; coefficient of variation/CV). Stratified by PPM, mean ADCs ranged from 1.136-1.206 *10 -3 mm 2 /s (∆ = 7.0 %). Variances between PPM were pronounced in the upper range of ADC values (maximum: 2.540-2.763 10 -3 mm 2 /s, ∆ = 8 %). Pairwise comparisons identified significant differences between all PPM (P ≤ 0.003; mean CV = 7.2 %) and reached 0.137 *10 -3 mm 2 /s within the 25th-75th percentile. Altering the PPM had a significant impact on the ADC value. This should be considered if ADC values from different post-processing methods are compared in patient studies. • Post-processing methods significantly influenced ADC values. • The mean coefficient of ADC variation due to PPM was 7.2 %. • To achieve reproducible ADC values, standardization of post-processing is recommended.
Chaumoitre, K; Colavolpe, N; Shojai, R; Sarran, A; D' Ercole, C; Panuel, M
2007-01-01
To assess the use of diffusion-weighted magnetic resonance imaging (DW-MRI) in the evaluation of the fetal kidney and to estimate age-dependent changes in the apparent diffusion coefficient (ADC) of normal and pathological fetal kidneys. DW-MRI was performed on a 1.5-T machine at 23-38 gestational weeks in 51 pregnant women in whom the fetal kidneys were normal and in 10 whose fetuses had renal pathology (three with suspected nephropathy, three with renal tract dilatation, one with unilateral renal venous thrombosis, and three with twin-twin transfusion syndrome (TTTS)). The ADC was measured in an approximately 1-cm2 region of interest within the renal parenchyma. ADC values in normal renal parenchyma ranged from 1.1 to 1.8 10(-3) mm2 s-1. There was no significant age-dependent change in the ADC of normal kidneys. In cases of nephropathy, the ADC value was not always pathological but an ADC map could show abnormal findings. In cases of dilatation, the ADC value was difficult to determine when the dilatation was huge. In cases of TTTS, the ADC of the donor twin was higher than that of the recipient twin and the difference seemed to be related to the severity of the syndrome. Evaluation of the ADC for fetal kidneys is feasible. Fetal measurement of the ADC value and ADC maps may be useful tools with which to explore the fetal kidney when used in conjunction with current methods. DW-MR images, ADC value and ADC map seem to be useful in cases of suspected nephropathy (hyperechoic kidneys), dilated kidney and vascular pathology (renal venous thrombosis, TTTS). Copyright (c) 2006 ISUOG.
Altered states of consciousness in epilepsy: a DTI study of the brain.
Xie, Fangfang; Xing, Wu; Wang, Xiaoyi; Liao, Weihua; Shi, Wei
2017-08-01
A disturbance in the level of consciousness is a classical clinical sign of several seizure types. Recent studies have shown that altered states of consciousness in seizures are associated with structural and functional changes of several brain regions. Prominent among these are the thalamus, the brain stem and the default mode network, which is part of the consciousness system. Our study used diffusion tensor imaging (DTI) to evaluate these brain regions in patients with three different types of epilepsies that are associated with altered consciousness: complex partial seizures (CPS), primary generalized tonic-clonic seizures (PGTCS) or secondary generalized tonic-clonic seizures (SGTCS). Additionally, this study further explores the probable mechanisms underlying impairment of consciousness in seizures. Conventional MRI and DTI scanning were performed in 51 patients with epilepsy and 51 healthy volunteers. The epilepsy group was in turn subdivided into three subgroups: CPS, PGTCS or SGTCS. Each subgroup comprised 17 patients. Each subject involved in the study underwent a DTI evaluation of the brain to measure the apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values of nine regions of interest: the postero-superior portion of midbrain, the bilateral dorsal thalamus, the bilateral precuneus/posterior cingulate, the bilateral medial pre-frontal gyri and the bilateral supramarginalgyri. The statistical significance of the measured ADC and FA values between the experimental and control groups was analysed using the paired t-test, and one-way analysis of variance was performed for a comparative analysis between the three subgroups. Statistically significantly higher ADC values ( p < 0.01) were observed in the bilateral dorsal thalamus and postero-superior aspect of the midbrain in the three patient subgroups than in the control group. There were no significant changes in the ADC values ( p > 0.05) in the bilateral precuneus/posterior cingulate, bilateral medial pre-frontal gyri or bilateral supramarginalgyri in the experimental group. Among the three patient subgroups and the ADC values of corresponding brain regions, there were no statistically significant changes. Statistically significantly lower FA values ( p < 0.05) were observed in the bilateral dorsal thalamus of the patients in the three subgroups than in the control group. Significantly lowered FA values from the postero-superior aspect of the mid brain ( p < 0.01) were observed in patients with PGTCS compared with the control group. There were no significant changes in the FA values ( p > 0.05) from the bilateral precuneus/posterior cingulate, bilateral medial frontal gyri or bilateral supramarginalgyri in the experimental group. Among the three patient subgroups and the FA values of the corresponding brain regions, there were no statistically significant changes. In epileptic patients with CPS, PGTCS or SGTCS, there seems to be a long-lasting neuronal dysfunction of the bilateral dorsal thalamus and postero-superior aspect of the midbrain. The thalamus and upper brain stem are likely to play a key role in epileptic patients with impaired consciousness.
Cihangiroglu, M M; Ozturk-Isik, E; Firat, Z; Kilickesmez, O; Ulug, A M; Ture, U
2017-03-01
The goal of this study was to compare diffusion-weighted magnetic resonance imaging (DW-MRI) using high b-value (b=3000s/mm 2 ) to DW-MRI using standard b-value (b=1000s/mm 2 ) in the preoperative grading of supratentorial gliomas. Fifty-three patients with glioma had brain DW-MRI at 3T using two different b-values (b=1000s/mm 2 and b=3000s/mm 2 ). There were 35 men and 18 women with a mean age of 40.5±17.1 years (range: 18-79 years). Mean, minimum, maximum, and range of apparent diffusion coefficient (ADC) values for solid tumor ROIs (ADC mean , ADC min , ADC max , and ADC diff ), and the normalized ADC (ADC ratio ) were calculated. A Kruskal-Wallis statistic with Bonferroni correction for multiple comparisons was applied to detect significant ADC parameter differences between tumor grades by including or excluding 19 patients with an oligodendroglioma. Receiver operating characteristic curve analysis was conducted to define appropriate cutoff values for grading gliomas. No differences in ADC derived parameters were found between grade II and grade III gliomas. Mean ADC values using standard b-value were 1.17±0.27×10 -3 mm 2 /s [range: 0.63-1.61], 1.05±0.22×10 -3 mm 2 /s [range: 0.73-1.33], and 0.86±0.23×10 -3 mm 2 /s [range: 0.52-1.46] for grades II, III and IV gliomas, respectively. Using high b-value, mean ADC values were 0.89±0.24×10 -3 mm 2 /s [range: 0.42-1.25], 0.82±0.20×10 -3 mm 2 /s [range: 0.56-1.10], and 0.59±0.17×10 -3 mm 2 /s [range: 0.40-1.01] for grades II, III and IV gliomas, respectively. ADC mean , ADC ratio , ADC max , and ADC min were different between grade II and grade IV gliomas at both standard and high b-values. Differences in ADC mean , ADC max , and ADC diff were found between grade III and grade IV only using high b-value. ADC parameters derived from DW-MRI using a high b-value allows a better differential diagnosis of gliomas, especially for differentiating grades III and IV, than those derived from DW-MRI using a standard b-value. Copyright © 2016 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Method and apparatus for low power analog-to-digital conversion
De Geronimo, Gianluigi; Nambiar, Neena
2013-10-01
A method and apparatus for analog-to-digital conversion. An Analog-to-Digital Converter (ADC) includes M ADC.sub.j, j=1, 2, . . . , M. Each ADC.sub.j comprises a number of cells each of which comprises a first switch, a second switch, a current sink and an inverter. An inverter of a cell in an ADC.sub.j changes state in response to a current associate with an input signal of the ADC.sub.j exceeding a threshold, thus switching on the next cell. Each ADC.sub.j is enabled to perform analog-to-digital conversion on a residual current of a previous ADC.sub.j-1 after the previous ADC.sub.j-1 has completed its analog-to-digital conversion and has been disabled.
Diagnostic value of ADC in patients with prostate cancer: influence of the choice of b values.
Thörmer, Gregor; Otto, Josephin; Reiss-Zimmermann, Martin; Seiwerts, Matthias; Moche, Michael; Garnov, Nikita; Franz, Toni; Do, Minh; Stolzenburg, Jens-Uwe; Horn, Lars-Christian; Kahn, Thomas; Busse, Harald
2012-08-01
To evaluate the influence of the choice of b values on the diagnostic value of the apparent diffusion coefficient (ADC) for detection and grading of prostate cancer (PCa). Forty-one patients with biopsy-proven PCa underwent endorectal 3-T MRI before prostatectomy. Different combinations of b values (0-800 s/mm(2)) were used to calculate four representative ADC maps. Mean ADCs of tumours and non-malignant tissue were determined. Tumour appearance on different ADC maps was rated by three radiologists as good, fair or poor by assigning a visual score (VS) of 2, 1 or 0, respectively. Differences in the ADC values with the choice of b values were analysed using one-way ANOVA. Choice of b values had a highly (P < 0.001) significant influence on the absolute ADC in each tissue. Maps using b = [50, 800] and [0, 800] were rated best (VS= 1.6 ± 0.3) and second best (1.1 ± 0.3, P < 0.001), respectively. For low-grade carcinomas (Gleason score ≤ 6, 13/41 patients), only the former choice received scores better than fair (VS = 1.4 ± 0.3). Mean tumour ADCs showed significant negative correlation (Spearman's ρ -0.38 to -0.46, P < 0.05) with Gleason score. Absolute ADC values strongly depend on the choice of b values and therefore should be used with caution for diagnostic purposes. A minimum b value greater than zero is recommended for ADC calculation to improve the visual assessment of PCa in ADC maps. • Absolute ADC values are highly dependent on the choice of b values. • Absolute ADC thresholds should be used carefully to predict tumour aggressiveness. • Subjective ratings of ADC maps involving b = 0 s/mm ( 2 ) are poor to fair. • Minimum b value greater than 0 s/mm ( 2 ) is recommended for ADC calculation.
Thust, S C; Hassanein, S; Bisdas, S; Rees, J H; Hyare, H; Maynard, J A; Brandner, S; Tur, C; Jäger, H R; Yousry, T A; Mancini, L
2018-03-23
To investigate if quantitative apparent diffusion coefficient (ADC) measurements can predict genetic subtypes of non-gadolinium-enhancing gliomas, comparing whole tumour against single slice analysis. Volumetric T2-derived masks of 44 gliomas were co-registered to ADC maps with ADC mean (ADC mean ) calculated. For the slice analysis, two observers placed regions of interest in the largest tumour cross-section. The ratio (ADC ratio ) between ADC mean in the tumour and normal appearing white matter was calculated for both methods. Isocitrate dehydrogenase (IDH) wild-type gliomas showed the lowest ADC values throughout (p < 0.001). ADC mean in the IDH-mutant 1p19q intact group was significantly higher than in the IDH-mutant 1p19q co-deleted group (p < 0.01). A volumetric ADC mean threshold of 1201 × 10 -6 mm 2 /s identified IDH wild-type with a sensitivity of 83% and a specificity of 86%; a volumetric ADC ratio cut-off value of 1.65 provided a sensitivity of 80% and a specificity of 92% (area under the curve (AUC) 0.9-0.94). A slice ADC ratio threshold for observer 1 (observer 2) of 1.76 (1.83) provided a sensitivity of 80% (86%), specificity of 91% (100%) and AUC of 0.95 (0.96). The intraclass correlation coefficient was excellent (0.98). ADC measurements can support the distinction of glioma subtypes. Volumetric and two-dimensional measurements yielded similar results in this study. • Diffusion-weighted MRI aids the identification of non-gadolinium-enhancing malignant gliomas • ADC measurements may permit non-gadolinium-enhancing glioma molecular subtyping • IDH wild-type gliomas have lower ADC values than IDH-mutant tumours • Single cross-section and volumetric ADC measurements yielded comparable results in this study.
A preprocessor for the Urbana coherent-scatter radar
NASA Technical Reports Server (NTRS)
Zendt, F. T.; Bowhill, S. A.
1982-01-01
The design, interfacing, testing, and operation of a preprocessor to increase the altitude and temporal resolution of the present coherent-scatter system are described. This system upgrade requires an increase in the data collection rate. Replacing the present, relatively slow, ADC with two high speed ADCs achieves the increased echo sampling rate desired. To stay within the capabilities of the main computer's I/O and processing rate the data must be reduced before transfer to the main computer. Thus the preprocessor also coherently integrates the data before transfer.
Lu, Shan Shan; Kim, Sang Joon; Kim, Namkug; Kim, Ho Sung; Choi, Choong Gon; Lim, Young Min
2015-04-01
This study intended to investigate the usefulness of histogram analysis of apparent diffusion coefficient (ADC) maps for discriminating primary CNS lymphomas (PCNSLs), especially atypical PCNSLs, from tumefactive demyelinating lesions (TDLs). Forty-seven patients with PCNSLs and 18 with TDLs were enrolled in our study. Hyperintense lesions seen on T2-weighted images were defined as ROIs after ADC maps were registered to the corresponding T2-weighted image. ADC histograms were calculated from the ROIs containing the entire lesion on every section and on a voxel-by-voxel basis. The ADC histogram parameters were compared among all PCNSLs and TDLs as well as between the subgroup of atypical PCNSLs and TDLs. ROC curves were constructed to evaluate the diagnostic performance of the histogram parameters and to determine the optimum thresholds. The differences between the PCNSLs and TDLs were found in the minimum ADC values (ADCmin) and in the 5th and 10th percentiles (ADC5% and ADC10%) of the cumulative ADC histograms. However, no statistical significance was found in the mean ADC value or in the ADC value concerning the mode, kurtosis, and skewness. The ADCmin, ADC5%, and ADC10% were also lower in atypical PCNSLs than in TDLs. ADCmin was the best indicator for discriminating atypical PCNSLs from TDLs, with a threshold of 556×10(-6) mm2/s (sensitivity, 81.3 %; specificity, 88.9%). Histogram analysis of ADC maps may help to discriminate PCNSLs from TDLs and may be particularly useful in differentiating atypical PCNSLs from TDLs.
Nurses' perceptions and experiences at daycare for elderly with stroke.
Park, Yeon-Hwan; Han, Hae-Ra
2010-09-01
While adult daycare (ADC) is considered a culturally acceptable model of long-term care in countries with a tradition of family-oriented caregiving, Korea is struggling as soaring needs for ADC outpace qualified staff and regulatory systems. This study aimed to describe Korean daycare nurses' perceptions of key daycare services and their working experiences with stroke patients and their families. A mixed-method design was used. First, we conducted a cross-sectional descriptive survey to assess Korean nurses' perceptions about the importance of daycare services. Then focus group interviews were performed to explore the nurses' experiences at ADC. Seventy of a total of 96 nurses at ADC that specialized in the care of stroke patients responded to the survey (response rate 72.9%) and rated the importance of 11 key daycare service items on a visual analogue scale (0-10). Using a purposive sampling design, 16 eligible nurses were interviewed as a group. The qualitative data from focus group interviews were analyzed using thematic analysis to classify common themes into larger categories. Survey data revealed that the nurses perceived "skilled nursing services,"functional recovery," and "general health counseling" as the most important daycare service areas. Focus group data resulted in five themes: "Providing the same, standard care,"Lack of partnership with family caregivers,"Conflict with other staff: ambiguity of the roles and tasks,"Lack of proper education and training," and "Need for quality control and monitoring." Daycare nurses fully recognized the importance of direct nursing care services that are keys to adequate recovery and rehabilitation of older patients with stroke. However, they experienced substantial barriers to carrying out these services due to role confusion, insufficient number of qualified nursing staff, and lack of partnership with family caregivers. The results provide insight into changing healthcare policy to support daycare nurses in a country with limited resources and regulations. Strategies such as better quality control and monitoring of daycare services, provision of continuing education, and prioritizing key services should be considered as a way to address challenges experienced by daycare nurses.
Infrared Sensor-Based Temperature Control for Domestic Induction Cooktops
Lasobras, Javier; Alonso, Rafael; Carretero, Claudio; Carretero, Enrique; Imaz, Eduardo
2014-01-01
In this paper, a precise real-time temperature control system based on infrared (IR) thermometry for domestic induction cooking is presented. The temperature in the vessel constitutes the control variable of the closed-loop power control system implemented in a commercial induction cooker. A proportional-integral controller is applied to establish the output power level in order to reach the target temperature. An optical system and a signal conditioning circuit have been implemented. For the signal processing a microprocessor with 12-bit ADC and a sampling rate of 1 Ksps has been used. The analysis of the contributions to the infrared radiation permits the definition of a procedure to estimate the temperature of the vessel with a maximum temperature error of 5 °C in the range between 60 and 250 °C for a known cookware emissivity. A simple and necessary calibration procedure with a black-body sample is presented. PMID:24638125
Infrared sensor-based temperature control for domestic induction cooktops.
Lasobras, Javier; Alonso, Rafael; Carretero, Claudio; Carretero, Enrique; Imaz, Eduardo
2014-03-14
In this paper, a precise real-time temperature control system based on infrared (IR) thermometry for domestic induction cooking is presented. The temperature in the vessel constitutes the control variable of the closed-loop power control system implemented in a commercial induction cooker. A proportional-integral controller is applied to establish the output power level in order to reach the target temperature. An optical system and a signal conditioning circuit have been implemented. For the signal processing a microprocessor with 12-bit ADC and a sampling rate of 1 Ksps has been used. The analysis of the contributions to the infrared radiation permits the definition of a procedure to estimate the temperature of the vessel with a maximum temperature error of 5 °C in the range between 60 and 250 °C for a known cookware emissivity. A simple and necessary calibration procedure with a black-body sample is presented.
Configurable analog-digital conversion using the neural engineering framework
Mayr, Christian G.; Partzsch, Johannes; Noack, Marko; Schüffny, Rene
2014-01-01
Efficient Analog-Digital Converters (ADC) are one of the mainstays of mixed-signal integrated circuit design. Besides the conventional ADCs used in mainstream ICs, there have been various attempts in the past to utilize neuromorphic networks to accomplish an efficient crossing between analog and digital domains, i.e., to build neurally inspired ADCs. Generally, these have suffered from the same problems as conventional ADCs, that is they require high-precision, handcrafted analog circuits and are thus not technology portable. In this paper, we present an ADC based on the Neural Engineering Framework (NEF). It carries out a large fraction of the overall ADC process in the digital domain, i.e., it is easily portable across technologies. The analog-digital conversion takes full advantage of the high degree of parallelism inherent in neuromorphic networks, making for a very scalable ADC. In addition, it has a number of features not commonly found in conventional ADCs, such as a runtime reconfigurability of the ADC sampling rate, resolution and transfer characteristic. PMID:25100933
Chandra and XMM Observations of the ADC Source 0921-630
NASA Technical Reports Server (NTRS)
Kallman, T. R.; Angelini, L.; Boroson, B.; Cottam, J.; White, Nicholas E. (Technical Monitor)
2002-01-01
We analyze observations of the low mass X-ray binary 2S0921-63 obtained with the gratings and CCDs on Chandra and XMM. This object is a high inclination system showing evidence for an accretion disk corona (ADC). Such a corona has the potential to constrain the properties of the heated accretion disk in this system, and other LMXBs by extension. We find evidence for line emission which is generally consistent with that found by previous experiments, although we are able to detect more lines. For the first time in this source, we find that the iron K line has multiple components. We set limits on the line widths and velocity offsets, and we fit the spectra to photoionization models and discuss the implications for accretion disk corona models. For the first time in any ADC source we use these fits, together with density constraints based on the O VII line ratio, in order to constrain the flux in the medium-ionization region of the ADC. Under various assumptions about the source luminosity this constrains the location of the emitting region. These estimates, together with estimates for the emission measure, favor a scenario in which the intrinsic luminosity of the source is comparable to what we observe.
Resonant Tunneling Analog-To-Digital Converter
NASA Technical Reports Server (NTRS)
Broekaert, T. P. E.; Seabaugh, A. C.; Hellums, J.; Taddiken, A.; Tang, H.; Teng, J.; vanderWagt, J. P. A.
1995-01-01
As sampling rates continue to increase, current analog-to-digital converter (ADC) device technologies will soon reach a practical resolution limit. This limit will most profoundly effect satellite and military systems used, for example, for electronic countermeasures, electronic and signal intelligence, and phased array radar. New device and circuit concepts will be essential for continued progress. We describe a novel, folded architecture ADC which could enable a technological discontinuity in ADC performance. The converter technology is based on the integration of multiple resonant tunneling diodes (RTD) and hetero-junction transistors on an indium phosphide substrate. The RTD consists of a layered semiconductor hetero-structure AlAs/InGaAs/AlAs(2/4/2 nm) clad on either side by heavily doped InGaAs contact layers. Compact quantizers based around the RTD offer a reduction in the number of components and a reduction in the input capacitance Because the component count and capacitance scale with the number of bits N, rather than by 2 (exp n) as in the flash ADC, speed can be significantly increased, A 4-bit 2-GSps quantizer circuit is under development to evaluate the performance potential. Circuit designs for ADC conversion with a resolution of 6-bits at 25GSps may be enabled by the resonant tunneling approach.
Farlow, Martin R; Grossberg, George T; Meng, Xiangyi; Olin, Jason; Somogyi, Monique
2011-12-01
The cholinesterase inhibitor rivastigmine is approved for the symptomatic treatment of mild to moderate Alzheimer's disease (AD). This exploratory, hypothesis-forming analysis assessed response to rivastigmine according to severity of dementia at baseline. This was a retrospective analysis of a large randomized, placebo-controlled trial (ENA713D2320). AD patients treated with 9.5 mg/24 h rivastigmine patch, 17.4 mg/24 h rivastigmine patch, rivastigmine capsule (12 mg/day), or placebo were stratified according to baseline Mini-Mental State Examination (MMSE) scores: ≥7 to ≤12 (severe disease), ≥13 to ≤15 (moderately severe), ≥16 to ≤18 (moderate), or ≥19 to ≤25 (mild to moderate). Changes from baseline at Week 24 on Alzheimer's Disease Assessment Scale-cognitive subscale (ADAS-cog), Alzheimer's Disease Cooperative Study-Clinical Global Impression of Change (ADCS-CGIC), and Alzheimer's Disease Cooperative Study-Activities of Daily Living (ADCS-ADL) were assessed. Based on baseline MMSE scores, 141, 228, 333, and 348 patients had severe, moderately severe, moderate, and mild to moderate dementia. Worsening of ADAS-cog, ADCS-CGIC, and ADCS-ADL scores in patients receiving placebo were greater in patients with more severe dementia. Significant improvements versus placebo were seen with rivastigmine patch and/or capsule on ADAS-cog, ADCS-CGIC, and ADCS-ADL scores in patients with severe, moderately severe, and moderate AD (all p < 0.05). However, no significant improvements were seen in rivastigmine-treated patients with mild to moderate AD. Rivastigmine benefits AD patients across dementia stages. Similar to previous cholinesterase inhibitor studies, greatest treatment effects with rivastigmine patch and capsule were seen in patients with more advanced dementia, most likely driven by greater placebo decline in this population. Copyright © 2010 John Wiley & Sons, Ltd.
Kim, Hyejung; Van Hoof, Chris; Yazicioglu, Refet Firat
2011-01-01
This paper describes a mixed-signal ECG processing platform with an 12-bit ADC architecture that can adapt its sampling rate according to the input signals rate of change. This enables the sampling of ECG signals with significantly reduced data rate without loss of information. The presented adaptive sampling scheme reduces the ADC power consumption, enables the processing of ECG signals with lower power consumption, and reduces the power consumption of the radio while streaming the ECG signals. The test results show that running a CWT-based R peak detection algorithm using the adaptively sampled ECG signals consumes only 45.6 μW and it leads to 36% less overall system power consumption.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gong, Nan-Jie; Wong, Chun-Sing, E-mail: drcswong@gmail.com; Chu, Yiu-Ching
2013-10-01
Purpose: To improve the accuracy of volume and apparent diffusion coefficient (ADC) measurements in diffusion-weighted magnetic resonance imaging (MRI), we proposed a method based on thresholding both the b0 images and the ADC maps. Methods and Materials: In 21 heterogeneous lesions from patients with metastatic gastrointestinal stromal tumors (GIST), gross lesion were manually contoured, and corresponding volumes and ADCs were denoted as gross tumor volume (GTV) and gross ADC (ADC{sub g}), respectively. Using a k-means clustering algorithm, the probable high-cellularity tumor tissues were selected based on b0 images and ADC maps. ADC and volume of the tissues selected using themore » proposed method were denoted as thresholded ADC (ADC{sub thr}) and high-cellularity tumor volume (HCTV), respectively. The metabolic tumor volume (MTV) in positron emission tomography (PET)/computed tomography (CT) was measured using 40% maximum standard uptake value (SUV{sub max}) as the lower threshold, and corresponding mean SUV (SUV{sub mean}) was also measured. Results: HCTV had excellent concordance with MTV according to Pearson's correlation (r=0.984, P<.001) and linear regression (slope = 1.085, intercept = −4.731). In contrast, GTV overestimated the volume and differed significantly from MTV (P=.005). ADC{sub thr} correlated significantly and strongly with SUV{sub mean} (r=−0.807, P<.001) and SUV{sub max} (r=−0.843, P<.001); both were stronger than those of ADC{sub g}. Conclusions: The proposed lesion-adaptive semiautomatic method can help segment high-cellularity tissues that match hypermetabolic tissues in PET/CT and enables more accurate volume and ADC delineation on diffusion-weighted MR images of GIST.« less
Internalization, Trafficking, Intracellular Processing and Actions of Antibody-Drug Conjugates.
Xu, Shi
2015-11-01
This review discusses the molecular mechanism involved in the targeting and delivery of antibody-drug conjugates (ADCs), the new class of biopharmaceuticals mainly designed for targeted cancer therapy. this review goes over major progress in preclinical and clinical studies of ADCs, in the past 5 years. The pharmacokinetics and pharmacodynamics of ADCs involve multiple mechanisms, including internalization of ADCs by target cells, intracellular trafficking, release of conjugated drugs, and payload. These mechanisms actually jointly determine the efficacy of ADCs. Therefore, the optimization of ADCs should take them as necessary rationales.
Design and demonstration of an advanced data collection/position location system
NASA Technical Reports Server (NTRS)
1977-01-01
The final report on a breadboard evaluation and demonstration program is reported concerning the applicability of MSK modulation and chirp-z transformer technology in Advanced Data Collection/Position Location (ADC/PL) systems. The program effort consisted of three phases - design, testing, and evaluation. Section 2 describes the breadboard hardware built during the design phase of the program, Section 3 describes the tests conducted on the breadboard and the results of the tests, and Section 4 presents a brief analysis and summary of the findings of the breadboard tests and develops a sample ADC/PL system which incorporates both MSK modulation and a chirp-z transformer.
NASA Astrophysics Data System (ADS)
Krasilenko, Vladimir G.; Lazarev, Alexander A.; Nikitovich, Diana V.
2017-10-01
The paper considers results of design and modeling of continuously logical base cells (CL BC) based on current mirrors (CM) with functions of preliminary analogue and subsequent analogue-digital processing for creating sensor multichannel analog-to-digital converters (SMC ADCs) and image processors (IP). For such with vector or matrix parallel inputs-outputs IP and SMC ADCs it is needed active basic photosensitive cells with an extended electronic circuit, which are considered in paper. Such basic cells and ADCs based on them have a number of advantages: high speed and reliability, simplicity, small power consumption, high integration level for linear and matrix structures. We show design of the CL BC and ADC of photocurrents and their various possible implementations and its simulations. We consider CL BC for methods of selection and rank preprocessing and linear array of ADCs with conversion to binary codes and Gray codes. In contrast to our previous works here we will dwell more on analogue preprocessing schemes for signals of neighboring cells. Let us show how the introduction of simple nodes based on current mirrors extends the range of functions performed by the image processor. Each channel of the structure consists of several digital-analog cells (DC) on 15-35 CMOS. The amount of DC does not exceed the number of digits of the formed code, and for an iteration type, only one cell of DC, complemented by the device of selection and holding (SHD), is required. One channel of ADC with iteration is based on one DC-(G) and SHD, and it has only 35 CMOS transistors. In such ADCs easily parallel code can be realized and also serial-parallel output code. The circuits and simulation results of their design with OrCAD are shown. The supply voltage of the DC is 1.8÷3.3V, the range of an input photocurrent is 0.1÷24μA, the transformation time is 20÷30nS at 6-8 bit binary or Gray codes. The general power consumption of the ADC with iteration is only 50÷100μW, if the maximum input current is 4μA. Such simple structure of linear array of ADCs with low power consumption and supply voltage 3.3V, and at the same time with good dynamic characteristics (frequency of digitization even for 1.5μm CMOS-technologies is 40÷50 MHz, and can be increased up to 10 times) and accuracy characteristics are show. The SMC ADCs based on CL BC and CM opens new prospects for realization of linear and matrix IP and photo-electronic structures with matrix operands, which are necessary for neural networks, digital optoelectronic processors, neural-fuzzy controllers.
Jackson, Dowdy; Atkinson, John; Guevara, Claudia I.; Zhang, Chunying; Kery, Vladimir; Moon, Sung-Ju; Virata, Cyrus; Yang, Peng; Lowe, Christine; Pinkstaff, Jason; Cho, Ho; Knudsen, Nick; Manibusan, Anthony; Tian, Feng; Sun, Ying; Lu, Yingchun; Sellers, Aaron; Jia, Xiao-Chi; Joseph, Ingrid; Anand, Banmeet; Morrison, Kendall; Pereira, Daniel S.; Stover, David
2014-01-01
Antibody drug conjugates (ADCs) are monoclonal antibodies designed to deliver a cytotoxic drug selectively to antigen expressing cells. Several components of an ADC including the selection of the antibody, the linker, the cytotoxic drug payload and the site of attachment used to attach the drug to the antibody are critical to the activity and development of the ADC. The cytotoxic drugs or payloads used to make ADCs are typically conjugated to the antibody through cysteine or lysine residues. This results in ADCs that have a heterogeneous number of drugs per antibody. The number of drugs per antibody commonly referred to as the drug to antibody ratio (DAR), can vary between 0 and 8 drugs for a IgG1 antibody. Antibodies with 0 drugs are ineffective and compete with the ADC for binding to the antigen expressing cells. Antibodies with 8 drugs per antibody have reduced in vivo stability, which may contribute to non target related toxicities. In these studies we incorporated a non-natural amino acid, para acetyl phenylalanine, at two unique sites within an antibody against Her2/neu. We covalently attached a cytotoxic drug to these sites to form an ADC which contains two drugs per antibody. We report the results from the first direct preclinical comparison of a site specific non-natural amino acid anti-Her2 ADC and a cysteine conjugated anti-Her2 ADC. We report that the site specific non-natural amino acid anti-Her2 ADCs have superior in vitro serum stability and preclinical toxicology profile in rats as compared to the cysteine conjugated anti-Her2 ADCs. We also demonstrate that the site specific non-natural amino acid anti-Her2 ADCs maintain their in vitro potency and in vivo efficacy against Her2 expressing human tumor cell lines. Our data suggests that site specific non-natural amino acid ADCs may have a superior therapeutic window than cysteine conjugated ADCs. PMID:24454709
Huang, Jinbai; Luo, Jing; Peng, Jie; Yang, Tao; Zheng, Huanghua; Mao, Chunping
2017-11-01
Background Diffusion-weighted imaging (DWI) was introduced into clinical use some years ago. However, its use in the diagnosis of cerebral schistosomiasis has not been reported. Purpose To investigate the ability of the apparent diffusion coefficient (ADC) value of DWI in the diagnosis of cerebral schistosomiasis, and to differentiate it from brain high-grade gliomas and metastasis. Material and Methods Conventional brain MRI with pre-contrast, post-contrast, and DWI was performed on 50 cases of cerebral schistosomiasis, high-grade glioma, and brain metastasis. The ADC values of the three lesions, the proximal and the distal perifocal edema were measured. In order to remove the individual difference effect of ADC values, relative ADC (rADC) values were calculated through dividing the ADC value of the lesion area by that of the contralateral normal white matter. rADC values were used to evaluate the differences among cerebral schistosomiasis, brain high-grade gliomas, and metastasis. Results rADC of cerebral schistosomiasis was significantly lower than rADC of brain metastasis ( P < 0.05), without any significant differences when compared with high-grade gliomas. rADC of proximal perifocal edema in cerebral schistosomiasis was significantly higher than in high-grade gliomas ( P < 0.010), but not different compared with brain metastasis. Conclusion DWI examination with ADC values of lesions and proximal perifocal edema might be helpful in the exact diagnosis of cerebral schistosomiasis.
Diffusion tensor imaging in evaluation of human skeletal muscle injury.
Zaraiskaya, Tatiana; Kumbhare, Dinesh; Noseworthy, Michael D
2006-08-01
To explore the capability and reliability of diffusion tensor magnetic resonance imaging (DTI) in the evaluation of human skeletal muscle injury. DTI of four patients with gastrocnemius and soleus muscles injuries was compared to eight healthy controls. Imaging was performed using a GE 3.0T short-bore scanner. A diffusion-weighted 2D spin echo echo-planar imaging (EPI) pulse sequence optimized for skeletal muscle was used. From a series of axially acquired diffusion tensor images the diffusion tensor eigenparameters (eigenvalues and eigenvectors), fractional anisotropy (FA), and apparent diffusion coefficient (ADC) were calculated and compared for injured and healthy calf muscles. Two dimensional (2D) projection maps of the principal eigenvectors were plotted to visualize the healthy and pathologic muscle fiber architectures. Clear differences in FA and ADC were observed in injured skeletal muscle, compared to healthy controls. Mean control FA was 0.23 +/- 0.02 for medial and lateral gastrocnemius (mg and lg) muscles, and 0.20 +/- 0.02 for soleus (sol) muscles. In all patients FA values were reduced compared to controls, to as low as 0.08 +/- 0.02. The ADC in controls ranged from 1.41 to 1.31 x 10(-9) m(2)/second, while in patients this was consistently higher. The 2D projection maps revealed muscle fiber disorder in injured calves, while in healthy controls the 2D projection maps show a well organized (ordered) fiber structure. DTI is a suitable method to assess human calf muscle injury.
Xu, Junzhong; Li, Ke; Smith, R. Adam; Waterton, John C.; Zhao, Ping; Ding, Zhaohua; Does, Mark D.; Manning, H. Charles; Gore, John C.
2016-01-01
Background Diffusion-weighted MRI (DWI) signal attenuation is often not mono-exponential (i.e. non-Gaussian diffusion) with stronger diffusion weighting. Several non-Gaussian diffusion models have been developed and may provide new information or higher sensitivity compared with the conventional apparent diffusion coefficient (ADC) method. However the relative merits of these models to detect tumor therapeutic response is not fully clear. Methods Conventional ADC, and three widely-used non-Gaussian models, (bi-exponential, stretched exponential, and statistical model), were implemented and compared for assessing SW620 human colon cancer xenografts responding to barasertib, an agent known to induce apoptosis via polyploidy. Bayesian Information Criterion (BIC) was used for model selection among all three non-Gaussian models. Results All of tumor volume, histology, conventional ADC, and three non-Gaussian DWI models could show significant differences between control and treatment groups after four days of treatment. However, only the non-Gaussian models detected significant changes after two days of treatment. For any treatment or control group, over 65.7% of tumor voxels indicate the bi-exponential model is strongly or very strongly preferred. Conclusion Non-Gaussian DWI model-derived biomarkers are capable of detecting tumor earlier chemotherapeutic response of tumors compared with conventional ADC and tumor volume. The bi-exponential model provides better fitting compared with statistical and stretched exponential models for the tumor and treatment models used in the current work. PMID:27919785
Yang, Ze-Hui; Zheng, Rui; Gao, Yuan; Zhang, Qiang
2016-09-01
With the widespread application of high-throughput technology, numerous meta-analysis methods have been proposed for differential expression profiling across multiple studies. We identified the suitable differentially expressed (DE) genes that contributed to lung adenocarcinoma (ADC) clustering based on seven popular multiple meta-analysis methods. Seven microarray expression profiles of ADC and normal controls were extracted from the ArrayExpress database. The Bioconductor was used to perform the data preliminary preprocessing. Then, DE genes across multiple studies were identified. Hierarchical clustering was applied to compare the classification performance for microarray data samples. The classification efficiency was compared based on accuracy, sensitivity and specificity. Across seven datasets, 573 ADC cases and 222 normal controls were collected. After filtering out unexpressed and noninformative genes, 3688 genes were remained for further analysis. The classification efficiency analysis showed that DE genes identified by sum of ranks method separated ADC from normal controls with the best accuracy, sensitivity and specificity of 0.953, 0.969 and 0.932, respectively. The gene set with the highest classification accuracy mainly participated in the regulation of response to external stimulus (P = 7.97E-04), cyclic nucleotide-mediated signaling (P = 0.01), regulation of cell morphogenesis (P = 0.01) and regulation of cell proliferation (P = 0.01). Evaluation of DE genes identified by different meta-analysis methods in classification efficiency provided a new perspective to the choice of the suitable method in a given application. Varying meta-analysis methods always present varying abilities, so synthetic consideration should be taken when providing meta-analysis methods for particular research. © 2015 John Wiley & Sons Ltd.
Iterative current mode per pixel ADC for 3D SoftChip implementation in CMOS
NASA Astrophysics Data System (ADS)
Lachowicz, Stefan W.; Rassau, Alexander; Lee, Seung-Minh; Eshraghian, Kamran; Lee, Mike M.
2003-04-01
Mobile multimedia communication has rapidly become a significant area of research and development constantly challenging boundaries on a variety of technological fronts. The processing requirements for the capture, conversion, compression, decompression, enhancement, display, etc. of increasingly higher quality multimedia content places heavy demands even on current ULSI (ultra large scale integration) systems, particularly for mobile applications where area and power are primary considerations. The ADC presented in this paper is designed for a vertically integrated (3D) system comprising two distinct layers bonded together using Indium bump technology. The top layer is a CMOS imaging array containing analogue-to-digital converters, and a buffer memory. The bottom layer takes the form of a configurable array processor (CAP), a highly parallel array of soft programmable processors capable of carrying out complex processing tasks directly on data stored in the top plane. This paper presents a ADC scheme for the image capture plane. The analogue photocurrent or sampled voltage is transferred to the ADC via a column or a column/row bus. In the proposed system, an array of analogue-to-digital converters is distributed, so that a one-bit cell is associated with one sensor. The analogue-to-digital converters are algorithmic current-mode converters. Eight such cells are cascaded to form an 8-bit converter. Additionally, each photo-sensor is equipped with a current memory cell, and multiple conversions are performed with scaled values of the photocurrent for colour processing.
2013-01-01
Background Data on the current burden of adenocarcinoma (ADC) and histology-specific human papillomavirus (HPV) type distribution are relevant to predict the future impact of prophylactic HPV vaccines. Methods We estimate the proportion of ADC in invasive cervical cancer, the global number of cases of cervical ADC in 2015, the effect of cervical screening on ADC, the number of ADC cases attributable to high-risk HPV types -16, -18, -45, -31 and -33, and the potential impact of HPV vaccination using a variety of data sources including: GLOBOCAN 2008, Cancer Incidence in Five Continents (CI5) Volume IX, cervical screening data from the World Health Organization/Institut Català d'Oncologia Information Centre on HPV and cervical cancer, and published literature. Results ADC represents 9.4% of all ICC although its contribution varies greatly by country and region. The global crude incidence rate of cervical ADC in 2015 is estimated at 1.6 cases per 100,000 women, and the projected worldwide incidence of ADC in 2015 is 56,805 new cases. Current detection rates for HPV DNA in cervical ADC tend to range around 80–85%; the lower HPV detection rates in cervical ADC versus squamous cell carcinoma may be due to technical artefacts or to misdiagnosis of endometrial carcinoma as cervical ADC. Published data indicate that the five most common HPV types found in cervical ADC are HPV-16 (41.6%), -18 (38.7%), -45 (7.0%), -31 (2.2%) and -33 (2.1%), together comprising 92% of all HPV positive cases. Future projections using 2015 data, assuming 100% vaccine coverage and a true HPV causal relation of 100%, suggest that vaccines providing protection against HPV-16/18 may theoretically prevent 79% of new HPV-related ADC cases (44,702 cases annually) and vaccines additionally providing cross-protection against HPV-31/33/45 may prevent 89% of new HPV-related ADC cases (50,769 cases annually). Conclusions It is predicted that the currently available HPV vaccines will be highly effective in preventing HPV-related cervical ADC. PMID:24261839
Value of 3 Tesla diffusion-weighted magnetic resonance imaging for assessing liver fibrosis
Papalavrentios, Lavrentios; Sinakos, Emmanouil; Chourmouzi, Danai; Hytiroglou, Prodromos; Drevelegas, Konstantinos; Constantinides, Manos; Drevelegas, Antonios; Talwalkar, Jayant; Akriviadis, Evangelos
2015-01-01
Background Limited data are available regarding the role of magnetic resonance imaging (MRI), particularly the new generation 3 Tesla technology, and especially diffusion-weighted imaging (DWI) in predicting liver fibrosis. The aim of our pilot study was to assess the clinical performance of the apparent diffusion coefficient (ADC) of liver parenchyma for the assessment of liver fibrosis in patients with non-alcoholic fatty liver disease (NAFLD). Methods 18 patients with biopsy-proven NAFLD underwent DWI with 3 Tesla MRI. DWI was performed with single-shot echo-planar technique at b values of 0-500 and 0-1000 s/mm2. ADC was measured in four locations in the liver and the mean ADC value was used for analysis. Staging of fibrosis was performed according to the METAVIR system. Results The median age of patients was 52 years (range 23-73). The distribution of patients in different fibrosis stages was: 0 (n=1), 1 (n=7), 2 (n=1), 3 (n=5), 4 (n=4). Fibrosis stage was poorly associated with ADC at b value of 0-500 s/mm2 (r= -0.30, P=0.27). However it was significantly associated with ADC at b value of 0-1000 s/mm2 (r= -0.57, P=0.01). For this b value (0-1000 s/mm2) the area under receiver-operating characteristic curve was 0.93 for fibrosis stage ≥3 and the optimal ADC cut-off value was 1.16 ×10-3 mm2/s. Conclusion 3 Tesla DWI can possibly predict the presence of advanced fibrosis in patients with NAFLD. PMID:25608776
Value of 3 Tesla diffusion-weighted magnetic resonance imaging for assessing liver fibrosis.
Papalavrentios, Lavrentios; Sinakos, Emmanouil; Chourmouzi, Danai; Hytiroglou, Prodromos; Drevelegas, Konstantinos; Constantinides, Manos; Drevelegas, Antonios; Talwalkar, Jayant; Akriviadis, Evangelos
2015-01-01
Limited data are available regarding the role of magnetic resonance imaging (MRI), particularly the new generation 3 Tesla technology, and especially diffusion-weighted imaging (DWI) in predicting liver fibrosis. The aim of our pilot study was to assess the clinical performance of the apparent diffusion coefficient (ADC) of liver parenchyma for the assessment of liver fibrosis in patients with non-alcoholic fatty liver disease (NAFLD). 18 patients with biopsy-proven NAFLD underwent DWI with 3 Tesla MRI. DWI was performed with single-shot echo-planar technique at b values of 0-500 and 0-1000 s/mm 2 . ADC was measured in four locations in the liver and the mean ADC value was used for analysis. Staging of fibrosis was performed according to the METAVIR system. The median age of patients was 52 years (range 23-73). The distribution of patients in different fibrosis stages was: 0 (n=1), 1 (n=7), 2 (n=1), 3 (n=5), 4 (n=4). Fibrosis stage was poorly associated with ADC at b value of 0-500 s/mm 2 (r= -0.30, P=0.27). However it was significantly associated with ADC at b value of 0-1000 s/mm 2 (r= -0.57, P=0.01). For this b value (0-1000 s/mm 2 ) the area under receiver-operating characteristic curve was 0.93 for fibrosis stage ≥3 and the optimal ADC cut-off value was 1.16 ×10 -3 mm 2 /s. 3 Tesla DWI can possibly predict the presence of advanced fibrosis in patients with NAFLD.
Fanikos, John; Erickson, Abbie; Munz, Kristin E; Sanborn, Mike D; Ludwig, Brad C; Van Hassel, Tom
2007-10-01
The use of ready-to-use (RTU) and point-of-care (POC) activated parenteral products and their storage in automated dispensing cabinets (ADCs) in U.S. hospitals were evaluated. A survey on the use of RTU and POC activated parenteral products, including storage and dispensing of the products, was developed and sent electronically to hospital pharmacy administrators. Survey respondents were identified using the American Society of Health-System Pharmacists' member database. Of the 4070 surveys sent, 965 (23.7%) were completed and returned. Most pharmacy administrators (94.7%) reported that their institution used some form of RTU and POC activated parenteral product, with 74% using ADCs to dispense these products. Efficiency was the most common reason cited for storage of RTU and POC activated products in ADCs. Facilities varied on reasons for not implementing this technology, with 47 facilities citing implementation costs, limited number of RTU and POC activated products on the hospital's formulary, lack of available pediatric formulations, and safety concerns as the main reasons. More than half of respondents noted space limitations as the greatest challenge to adding RTU and POC activated products to ADCs. Nearly three fourths of survey respondents reported using RTU and POC products in conjunction with ADCs; however, the approach to including these products in ADCs varied based on the characteristics, policies, and preferences of the individual facility. Advantages of RTU and POC products identified by respondents included enhanced safety benefits, increased dispensing efficiency, cost avoidance due to reduced waste, and improved compliance with federal and state regulations.
NASA Astrophysics Data System (ADS)
DePriest, Christopher M.; Abeles, Joseph H.; Braun, Alan; Delfyett, Peter J., Jr.
2000-07-01
External-cavity, actively-modelocked semiconductor diode lasers (SDLs) have proven to be attractive candidates for forming the backbone of next-generation analog-to-digital converters (ADCs), which are currently being developed to sample signals at repetition rates exceeding several GHz with up to 12 bits of digital resolution. Modelocked SDLs are capable of producing waveform-sampling pulse trains with very low temporal jitter (phase noise) and very small fluctuations in pulse height (amplitude noise)--two basic conditions that must be met in order for high-speed ADCs to achieve projected design goals. Single-wavelength modelocked operation (at nominal repetition frequencies of 400 MHz) has produced pulse trains with very low amplitude noise (approximately 0.08%), and the implementation of a phase- locked-loop has been effective in reducing the system's low- frequency phase noise (RMS timing jitter for offset frequencies between 10 Hz and 10 kHz has been reduced from 240 fs to 27 fs).
Tang, Qi; Li, Qiang; Xie, Dong; Chu, Ketao; Liu, Lidong; Liao, Chengcheng; Qin, Yunying; Wang, Zheng; Su, Danke
2018-05-21
This study aimed to investigate the utility of a volumetric apparent diffusion coefficient (ADC) histogram method for distinguishing non-puerperal mastitis (NPM) from breast cancer (BC) and to compare this method with a traditional 2-dimensional measurement method. Pretreatment diffusion-weighted imaging data at 3.0 T were obtained for 80 patients (NPM, n = 27; BC, n = 53) and were retrospectively assessed. Two readers measured ADC values according to 2 distinct region-of-interest (ROI) protocols. The first protocol included the generation of ADC histograms for each lesion, and various parameters were examined. In the second protocol, 3 freehand (TF) ROIs for local lesions were generated to obtain a mean ADC value (defined as ADC-ROITF). All of the ADC values were compared by an independent-samples t test or the Mann-Whitney U test. Receiver operating characteristic curves and a leave-one-out cross-validation method were also used to determine diagnostic deficiencies of the significant parameters. The ADC values for NPM were characterized by significantly higher mean, 5th to 95th percentiles, and maximum and mode ADCs compared with the corresponding ADCs for BC (all P < 0.05). However, the minimum, skewness, and kurtosis ADC values, as well as ADC-ROITF, did not significantly differ between the NPM and BC cases. Thus, the generation of volumetric ADC histograms seems to be a superior method to the traditional 2-dimensional method that was examined, and it also seems to represent a promising image analysis method for distinguishing NPM from BC.
Bickel, Hubert; Pinker, Katja; Polanec, Stephan; Magometschnigg, Heinrich; Wengert, Georg; Spick, Claudio; Bogner, Wolfgang; Bago-Horvath, Zsuzsanna; Helbich, Thomas H; Baltzer, Pascal
2017-05-01
To investigate the influence of region-of-interest (ROI) placement and different apparent diffusion coefficient (ADC) parameters on ADC values, diagnostic performance, reproducibility and measurement time in breast tumours. In this IRB-approved, retrospective study, 149 histopathologically proven breast tumours (109 malignant, 40 benign) in 147 women (mean age 53.2) were investigated. Three radiologists independently measured minimum, mean and maximum ADC, each using three ROI placement approaches:1 - small 2D-ROI, 2 - large 2D-ROI and 3 - 3D-ROI covering the whole lesion. One reader performed all measurements twice. Median ADC values, diagnostic performance, reproducibility, and measurement time were calculated and compared between all combinations of ROI placement approaches and ADC parameters. Median ADC values differed significantly between the ROI placement approaches (p < .001). Minimum ADC showed the best diagnostic performance (AUC .928-.956), followed by mean ADC obtained from 2D ROIs (.926-.94). Minimum and mean ADC showed high intra- (ICC .85-.94) and inter-reader reproducibility (ICC .74-.94). Median measurement time was significantly shorter for the 2D ROIs (p < .001). ROI placement significantly influences ADC values measured in breast tumours. Minimum and mean ADC acquired from 2D-ROIs are useful for the differentiation of benign and malignant breast lesions, and are highly reproducible, with rapid measurement. • Region of interest placement significantly influences apparent diffusion coefficient of breast tumours. • Minimum and mean apparent diffusion coefficient perform best and are reproducible. • 2D regions of interest perform best and provide rapid measurement times.
Yim, Jae Hyun; Kim, Chan Kyo; Kim, Jae-Hun
2018-04-01
Active surveillance (AS) is an important treatment strategy for prostate cancer (PCa). Prostate Imaging-Reporting and Data System (PI-RADS) v2 has been addressed, but few studies have reported the value of PI-RADS v2 for assessing risk stratification in patients with PCa, especially on selecting potential candidates for AS. To investigate the utility of PI-RADS v2 and apparent diffusion coefficient (ADC) in evaluating patients with insignificant PCa, who are suitable for AS. Retrospective. In all, 238 patients with PCa who met the Prostate Cancer Research International: Active Surveillance criteria underwent radical prostatectomy. 3.0T, including T 2 -weighted, diffusion-weighted, and dynamic contrast-enhanced imaging. Insignificant cancer was defined histopathologically as an organ-confined disease with a tumor volume <0.5 cm 3 without Gleason score 4-5. Patients were divided into two groups based on the PI-RADS v2 and tumor ADC: A, PI-RADS score ≤3 and ADC ≥1.095 × 10 -3 mm 2 /s; and B, PI-RADS score 4-5 or ADC <1.095 × 10 -3 mm 2 /s. Preoperative clinical and imaging variables were evaluated regarding the associations with insignificant cancer. Of the 238 patients, 101 (42.8%) were diagnosed with insignificant cancer on pathological findings. The number of positive cores, prostate-specific antigen density (PSAD), PI-RADS v2 and tumor ADC were significantly associated with insignificant cancer on univariate analysis (P < 0.05). However, multivariate analysis indicated tumor ADC (odds ratio [OR] = 4.57, P < 0.001) and PI-RADS v2 (OR = 3.60, P < 0.001) were independent predictors of insignificant cancer. Area under the receiver operating characteristics curve (AUC) reached 0.803 when PI-RADS v2 (AUC = 0.747) was combined with tumor ADC (AUC = 0.786). The PI-RADS v2 together with tumor ADC may be a useful marker for predicting patients with insignificant PCa when considering AS. 4 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:1072-1079. © 2017 International Society for Magnetic Resonance in Medicine.
NASA Astrophysics Data System (ADS)
Tanaka, Suiki; Niitsu, Kiichi; Nakazato, Kazuo
2016-03-01
Low-power analog-to-digital conversion is a key technique for power-limited biomedical applications such as power-limited continuous glucose monitoring. However, a conventional uniform-sampling analog-to-digital converter (ADC) is not suitable for nonuniform biosignals. A level-crossing ADC (LC-ADC) is a promising candidate for low-power biosignal processing because of its event-driven properties. The LC-ADC acquires data by level-crossing sampling. When an input signal crosses the threshold level, the LC-ADC samples the signal. The conventional LC-ADC employs a power-hungry comparator. In this paper, we present a low-power inverter-based LC-ADC. By adjusting the threshold level of the inverter, it can be used as a threshold-fixed window comparator. By using the inverter as an alternative to a comparator, power consumption can be markedly reduced. As a result, the total power consumption is successfully reduced by 90% of that of previous LC-ADC. The inverter-based LC-ADC was found to be very suitable for use in power-limited biomedical devices.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lambrecht, Maarten, E-mail: maarten.lambrecht@uzleuven.be; Vandecaveye, Vincent; De Keyzer, Frederik
2012-02-01
Purpose: To evaluate diffusion-weighted magnetic resonance imaging (DWI) for response prediction before and response assessment during and early after preoperative radiochemotherapy (RCT) for locally advanced rectal cancer (LARC). Methods and Materials: Twenty patients receiving RCT for LARC underwent MRI including DWI before RCT, after 10-15 fractions and 1 to 2 weeks before surgery. Tumor volume and apparent diffusion coefficient (ADC; b-values: 0-1000 s/mm{sup 2}) were determined at all time points. Pretreatment tumor ADC and volume, tumor ADC change ( Increment ADC), and volume change ( Increment V) between pretreatment and follow-up examinations were compared with histopathologic findings after total mesorectalmore » excision (pathologic complete response [pCR] vs. no pCR, ypT0-2 vs. ypT3-4, T-downstaging or not). The discriminatory capability of pretreatment tumor ADC and volume, Increment ADC, and Increment V for the detection of pCR was compared with receiver operating characteristics analysis. Results: Pretreatment ADC was significantly lower in patients with pCR compared with patients without (in mm{sup 2}/s: 0.94 {+-} 0.12 Multiplication-Sign 10{sup -3} vs. 1.19 {+-} 0.22 Multiplication-Sign 10{sup -3}, p = 0.003), yielding a sensitivity of 100% and specificity of 86% for detection of pCR. The volume reduction during and after RCT was significantly higher in patients with pCR compared with patients without (in %: {Delta}V{sub during}: -62 {+-} 16 vs. -33 {+-} 16, respectively, p = 0.015; and {Delta}V{sub post}: -86 {+-} 12 vs. -60 {+-} 21, p = 0.012), yielding a sensitivity of 83% and specificity of 71% for the {Delta}V{sub during} and, respectively, 83% and 86% for the {Delta}V{sub post}. The Increment ADC during ({Delta}ADC{sub during}) and after RCT ({Delta}ADC{sub post}) showed a significantly higher value in patients with pCR compared with patients without (in %: {Delta}ADC{sub during}: 72 {+-} 14 vs. 16 {+-} 12, p = 0.0006; and {Delta}ADC{sub post}: 88 {+-} 35 vs. 26 {+-} 19, p = 0.0011), yielding a sensitivity and specificity of 100% for the {Delta}ADC{sub during} and, respectively, 100% and 93% for the {Delta}ADC{sub post}. Conclusions: These initial findings indicate that DWI, using pretreatment ADC, {Delta}ADC{sub during}, and {Delta}ADC{sub post} may be useful for prediction and early assessment of pathologic response to preoperative RCT of LARC, with higher accuracy than volumetric measurements.« less
Operations Manual for the National Center for Physical Acoustics Infrasound Microphone
2013-02-01
thumbdrive.) There are three sections of the configuration file that can be edited: sensorConfig, adcConfig and autoControl . Modifying any other...for autoControl autoControl = { options = ( { doSchedule = 0; if nonzero, hourly scheduler is enabled
Provenzale, James M; Liang, Luxia; DeLong, David; White, Leonard E
2007-08-01
The purpose of this study was to use diffusion-weighted and diffusion tensor imaging to investigate the status of cerebral white matter (WM) at term gestation and the rate of WM maturation throughout the first year of life in healthy infants. Fifty-three children (35 boys) ranging in age from 1.5 weeks premature to 51.5 weeks (mean age, 22.9 weeks) underwent conventional MRI, diffusion imaging in three directions (b = 1,000 s/mm2), and diffusion tensor imaging with gradient encoding in six directions, all on a 1.5-T MRI system. Apparent diffusion coefficient (ADC) and fractional anisotropy (FA) were measured in three deep WM structures (posterior limb of internal capsule, genu, and splenium of corpus callosum) and two peripheral WM regions (associational WM underlying prefrontal and posterior parietal cortex) with a standard region of interest (44 +/- 4 cm2). ADC and FA were expressed as a percentage of corresponding values measured in a group of healthy young adults. Mean ADC and FA values for deep and peripheral WM were plotted against gestational age normalized to term. The data were fit best with a broken-line linear regression model with a breakpoint at 100 days. ADC and FA values at term were estimated according to the intercept of the initial linear period (before day 100) with day 0. The slope of the linear fits was used to determine the rate of WM maturation in both the early and the late (after day 100) periods. Multivariate analysis of variance tests were used to compare deep and peripheral WM structures at term and at representative early and late ages (days 30 and 200) and to compare rates of ADC and FA maturation in early and late periods within the first year. At term, peripheral WM was less mature than deep WM according to results of extrapolation of ADC and FA values in the first 100 days of life to day 0 (p < 0.01). Mean ADC and FA value (percentage of mean adult value) for peripheral WM were 1.32 x 10(-3) mm2/s (163%) and 0.16 (32%), respectively, and 1.09 x 10(-3) mm2/s (143%) and 0.36 (54%), respectively, for deep WM. On day 30 and day 200, estimated mean ADC and FA continued to show greater diffusion (higher ADC) and less anisotropy (lower FA value) in peripheral WM (p <0.01). During the first year of postnatal life, both ADC and FA matured at higher rates before postnatal day 100 compared with a later time. Differences were observed in rates of maturation in the first 100 days when rates of decrease in ADC and increase in FA were compared between peripheral WM and deep WM; however, the maturational trends differed whether ADC or FA was examined. The early rate of ADC decrease (maturation) was twice as great for peripheral WM than for deep WM (p < 0.01) unexpectedly, but the opposite pattern was observed for FA. The early rate of FA increase (maturation) was approximately one half as great for peripheral WM as for deep WM (p = 0.01). Throughout the rest of the first year, no differences were observed in the rates of change in either index between peripheral WM and deep WM. At term, both ADC and FA differ significantly in peripheral WM and deep WM, deep WM structures being more mature. Both deep WM and peripheral WM mature more rapidly during approximately the first 3 months in comparison with the rest of the first year. Unexpected differences in early (first 100 days) rates of maturation assessed with diffusion-weighted (ADC) and diffusion tensor (FA) imaging suggest that these two techniques may be sensitive to different aspects of WM maturation in the early perinatal period.
Fan, Shiyong; Zhong, Wu; Zhou, Xinbo; Li, Song
2017-01-01
Antibody-drug conjugates (ADCs), designed to selectively deliver cytotoxic agents to antigen-bearing cells, are poised to become an important class of cancer therapeutics. Human epithelial growth factor receptor (HER2) is considered an effective target for cancer treatment, and a HER2-targeting ADC has shown promising results. Most ADCs undergoing clinical evaluation contain linkers that have a lysosomal protease-cleavable dipeptide, of which the most common is valine-citrulline (VC). However, valine-alanine (VA), another dipeptide comprising two human essential amino acids, has been used in next generation ADCs loading new toxins, but the druggable properties of ADCs loaded the most popular monomethyl auristatin E (MMAE) remain to be further explored. In this study, we generated VA-based ADCs that connected MMAE to an anti-HER2 antibody. We studied the differences in the preparation process, in vitro stability, cathepsin B activity and in vitro cytotoxicity of VA-based ADC compared to the ADC of VC. VA had comparable performance to VC, which preliminarily displays its practicability. Additional efficacy and safety studies in a xenograft model indicate this novel ADC exerted potent anti-tumor activity and negligible toxicity. The results of this study show the application potential of VA-based ADC with MMAE as the payload. PMID:28841157
Wang, Yanming; Fan, Shiyong; Zhong, Wu; Zhou, Xinbo; Li, Song
2017-08-25
Antibody-drug conjugates (ADCs), designed to selectively deliver cytotoxic agents to antigen-bearing cells, are poised to become an important class of cancer therapeutics. Human epithelial growth factor receptor (HER2) is considered an effective target for cancer treatment, and a HER2-targeting ADC has shown promising results. Most ADCs undergoing clinical evaluation contain linkers that have a lysosomal protease-cleavable dipeptide, of which the most common is valine-citrulline (VC). However, valine-alanine (VA), another dipeptide comprising two human essential amino acids, has been used in next generation ADCs loading new toxins, but the druggable properties of ADCs loaded the most popular monomethyl auristatin E (MMAE) remain to be further explored. In this study, we generated VA-based ADCs that connected MMAE to an anti-HER2 antibody. We studied the differences in the preparation process, in vitro stability, cathepsin B activity and in vitro cytotoxicity of VA-based ADC compared to the ADC of VC. VA had comparable performance to VC, which preliminarily displays its practicability. Additional efficacy and safety studies in a xenograft model indicate this novel ADC exerted potent anti-tumor activity and negligible toxicity. The results of this study show the application potential of VA-based ADC with MMAE as the payload.
Zhao, Hua; Xu, Can; Luo, Xiaoli; Wei, Feng; Wang, Ning; Shi, Huiying; Ren, Xiubao
2018-01-01
Since the preclinical results about chimpanzee adenovirus serotype-68 (AdC68)-based vaccine showed an encouraging results, it reminded us that AdC68 may be a suitable cancer vaccine vector. Previous study indicated that the seroprevalence of neutralizing antibodies (NAbs) against adenovirus was different between cancer patients and healthy volunteers. Knowledge regarding the prevalence rates of AdC68 NAbs for cancer patients is lacking. Therefore, assessing the preexistence of NAbs against AdC68 in cancer patients could provide useful insights for developing future AdC68-based cancer vaccines. In this study, 440 patients with different pathological types of tumors and 204 healthy adult volunteers were enrolled to evaluate the NAbs against AdC68 and human adenovirus serotype-5 (AdHu5). The seroprevalence of NAbs against AdC68 was much lower than that against AdHu5 in cancer subjects (43.64 vs. 67.05%, P < 0.01). The seroprevalence rates of NAbs to AdC68 in the cancer subjects were statistically higher than those detected in the healthy adult volunteers (43.64 vs. 23.53%, P = 0.000). The seroprevalence rates of AdC68 NAbs were much lower in lung, laryngeal, esophageal, and cervical cancer patients compared with oropharyngeal, colon, and rectal cancer patients. Furthermore, the seroprevalence rates of AdC68 NAbs were much lower in lung adenocarcinoma patients than in lung squamous cell carcinoma patients (35.00 vs. 70.00%, P < 0.05). No significant difference in the AdC68 NAbs among patients with different clinical stages of cancer was detected. The percentage of NAbs against AdC68 was significantly lower than that against AdHu5 (P < 0.05) in stage-I, -II, and -III cancer patients. No significant difference between the percentage of NAbs against AdC68 and AdHu5 in the subjects with stage-IV cancer was detected. The study also demonstrated the distribution of AdHu5 and AdC68 NAb titers for the positive samples. It showed that very low NAb titers against AdC68 with respect to AdHu5 in both healthy subjects and cancer subjects, especially in lung, laryngeal, esophageal, gastric, and cervical carcinomas. Also, the titer of NAbs against AdC68 was significantly lower than that against AdHu5 in the same clinical stage and age group (P < 0.05). Taken together, the present study showed that NAbs against AdC68 is much lower than AdHu5, especially in lung adenocarcinoma, laryngeal cancer, esophageal cancer, and cervical cancer patients. These results provided strong support for candidating AdC68 as a suitable vector of cancer vaccines. PMID:29563911
Improved Lysosomal Trafficking Can Modulate the Potency of Antibody Drug Conjugates.
DeVay, Rachel M; Delaria, Kathy; Zhu, Guoyun; Holz, Charles; Foletti, Davide; Sutton, Janette; Bolton, Gary; Dushin, Russell; Bee, Christine; Pons, Jaume; Rajpal, Arvind; Liang, Hong; Shelton, David; Liu, Shu-Hui; Strop, Pavel
2017-04-19
Antibody drug conjugates (ADCs) provide an efficacious and relatively safe means by which chemotherapeutic agents can be specifically targeted to cancer cells. In addition to the selection of antibody targets, ADCs offer a modular design that allows selection of ADC characteristics through the choice of linker chemistries, toxins, and conjugation sites. Many studies have indicated that release of toxins bound to antibodies via noncleavable linker chemistries relies on the internalization and intracellular trafficking of the ADC. While this can make noncleavable ADCs more stable in the serum, it can also result in lower efficacy when their respective targets are not internalized efficiently or are recycled back to the cell surface following internalization. Here, we show that a lysosomally targeted ADC against the protein APLP2 mediates cell killing, both in vitro and in vivo, more effectively than an ADC against Trop2, a protein with less efficient lysosomal targeting. We also engineered a bispecific ADC with one arm targeting HER2 for the purpose of directing the ADC to tumors, and the other arm targeting APLP2, whose purpose is to direct the ADC to lysosomes for toxin release. This proof-of-concept bispecific ADC demonstrates that this technology can be used to shift the intracellular trafficking of a constitutively recycled target by directing one arm of the antibody against a lysosomally delivered protein. Our data also show limitations of this approach and potential future directions for development.
Sala, Evis; Kataoka, Masako Y; Priest, Andrew N; Gill, Andrew B; McLean, Mary A; Joubert, Ilse; Graves, Martin J; Crawford, Robin A F; Jimenez-Linan, Mercedes; Earl, Helena M; Hodgkin, Charlotte; Griffiths, John R; Lomas, David J; Brenton, James D
2012-04-01
To investigate the role of multiparametric magnetic resonance (MR) imaging in the evaluation of response to platinum-based neoadjuvant chemotherapy in advanced ovarian cancer and to compare imaging parameters between primary ovarian mass and metastatic disease. Evaluable patients suspected of having advanced ovarian carcinoma were enrolled in a prospective protocol-driven study. Research ethics committee approval and written informed consent were obtained. Multiparametric MR imaging (diffusion-weighted MR imaging, dynamic contrast material-enhanced [DCE] MR imaging, and hydrogen 1 MR spectroscopy) was performed with a 3.0-T wholebody MR imaging system. Three marker lesions-primary ovarian mass, omental cake, and peritoneal deposit-were outlined by a radiologist on apparent diffusion coefficient (ADC) and vascular signal fraction (VSF) maps and on DCE MR images. Comparisons of mean ADC, mean VSF, DCE MR imaging parameters, and choline concentration between responders and nonresponders were based on Response Evaluation Criteria in Solid Tumors and CA-125 criteria. Twenty-two patients were evaluable. The mean ADC for peritoneal metastases was lower than that for ovarian (P = .015) and omental (P = .006) sites. There were no differences in pretreatment DCE MR imaging parameters between tumor sites. After treatment, responders showed a significantly larger increase in ADC (P = .021) and fractional volume of the extravascular extracellular space (v(e)) (P = .025) of ovarian lesions compared with nonresponders, but there was no change in ADC at other sites. Pre- and posttreatment values of choline concentration of ovarian lesions were lower in responders (P = .025) than in nonresponders (P = .010). The significant differences in baseline ADCs among primary ovarian cancer, omental cake, and peritoneal deposits indicate that diffusivity profiles may be tumor-site dependent, suggesting biologic heterogeneity of disease. ADC and v(e) parameters correlated with the cytotoxic effects of platinum-based therapy and may be useful response markers, while choline concentration predicted but did not reflect response. © RSNA, 2012.
A sub-microwatt asynchronous level-crossing ADC for biomedical applications.
Li, Yongjia; Zhao, Duan; Serdijn, Wouter A
2013-04-01
A continuous-time level-crossing analog-to-digital converter (LC-ADC) for biomedical applications is presented. When compared to uniform-sampling (US) ADCs LC-ADCs generate fewer samples for various sparse biomedical signals. Lower power consumption and reduced design complexity with respect to conventional LC-ADCs are achieved due to: 1) replacing the n-bit digital-to-analog converter (DAC) with a 1-bit DAC; 2) splitting the level-crossing detections; and 3) fixing the comparison window. Designed and implemented in 0.18 μm CMOS technology, the proposed ADC uses a chip area of 220 × 203 μm(2). Operating from a supply voltage of 0.8 V, the ADC consumes 313-582 nW from 5 Hz to 5 kHz and achieves an ENOB up to 7.9 bits.
Singer, Adam D; Pattany, Pradip M; Fayad, Laura M; Tresley, Jonathan; Subhawong, Ty K
2016-01-01
Determine interobserver concordance of semiautomated three-dimensional volumetric and two-dimensional manual measurements of apparent diffusion coefficient (ADC) values in soft tissue masses (STMs) and explore standard deviation (SD) as a measure of tumor ADC heterogeneity. Concordance correlation coefficients for mean ADC increased with more extensive sampling. Agreement on the SD of tumor ADC values was better for large regions of interest and multislice methods. Correlation between mean and SD ADC was low, suggesting that these parameters are relatively independent. Mean ADC of STMs can be determined by volumetric quantification with high interobserver agreement. STM heterogeneity merits further investigation as a potential imaging biomarker that complements other functional magnetic resonance imaging parameters. Copyright © 2016 Elsevier Inc. All rights reserved.
Report: landfill alternative daily cover: conserving air space and reducing landfill operating cost.
Haughey, R D
2001-02-01
Title 40, Part 258 of the Code of Federal Regulations, Solid Waste Disposal Facility Criteria, commonly referred to as Subtitle D, became effective on October 9, 1993. It establishes minimum criteria for solid waste disposal facility siting, design, operations, groundwater monitoring and corrective action, and closure and postclosure maintenance, while providing EPA-approved state solid waste regulatory programs flexibility in implementing the criteria. Section 258.21(a) [40 CFR 258.21(a)] requires owners or operators of municipal solid waste landfill (MSWLF) units to cover disposed solid waste with 30cm of earthen material at the end of the operating day, or at more frequent intervals, if necessary, to control disease vectors, fires, odours, blowing litter, and scavenging. This requirement is consistent with already existing solid waste facility regulations in many states. For many MSWLFs, applying daily cover requires the importation of soil which increases landfill operating costs. Daily cover also uses valuable landfill air space, reducing potential operating revenue and the landfill's operating life. 40 CFR 258.21 (b) allows the director of an approved state to approve alternative materials of an alternative thickness if the owner or operator demonstrates that the alternative material and thickness will control disease vectors, fires, odours, blowing litter, and scavenging without presenting a threat to human health and the environment. Many different types of alternative daily cover (ADC) are currently being used, including geosynthetic tarps, foams, garden waste, and auto shredder fluff. These materials use less air space than soil and can reduce operating costs. This paper discusses the variety of ADCs currently being used around the country and their applicability to different climates and operating conditions, highlighting the more unusual types of ADC, the types of demonstrations necessary to obtain approval of ADC, and the impact on landfill air space and operating costs of ADC use.
Zhang, Li; Li, Meng; Wu, Ning; Chen, Yuheng
2015-01-01
Objectives This study aims to describe time trends of epidemiologic characteristics and imaging features over 14 years among histologically confirmed lung adenocarcinoma (ADC) in China and to discuss the possible reasons for these changes. Materials and Methods Data of 21,113 pathologically confirmed lung cancer patients from January 1999 to December 2012 were analyzed retrospectively. Preoperative high-resolution computer tomography (HRCT) images were available and reviewed in 5,439 lung ADC patients since 2005. Time trends of the ADC proportion of lung cancer cases, gender distribution, age at diagnosis, the proportion of early-stage ADC and imaging features were investigated. Results The proportion of ADC increased during the 14 years (P = 0.000). The ratio of female to male ADC cases was higher than both squamous cell carcinoma (SQCC) and total lung cancer cases (P = 0.000). The median age at diagnosis of ADC patients was younger than that of both SQCC and total lung cancer during the 14 years (P = 0.000). The proportion of age group 45–59 years increased in total lung cancer cases (P = 0.000). When stratified by lung cancer histopathologic subtypes, this trend was also observed in ADC (P = 0.001) and SQCC (P = 0.007). The proportion of early-stage cases of ADC increased from 2008 to 2012 (P < 0.001). The proportion of subsolid nodules (SSN) in ADC increased (P = 0.001) from 2005 to 2012. Conclusion The data suggests that the proportion of ADC increased from 1999 to 2012 especially in middle-aged, female patients; early-stage ADC and SSN on HRCT images gradually increased, which may have been caused by a change in smoking habits and increased application of HRCT. PMID:26317971
A Potential Mechanism for ADC-Induced Neutropenia: Role of Neutrophils in Their Own Demise.
Zhao, Hui; Gulesserian, Sara; Malinao, Maria Christina; Ganesan, Sathish Kumar; Song, James; Chang, Mi Sook; Williams, Melissa M; Zeng, Zhilan; Mattie, Michael; Mendelsohn, Brian A; Stover, David R; Doñate, Fernando
2017-09-01
Neutropenia is a common adverse event in cancer patients treated with antibody-drug conjugates (ADC) and we aimed to elucidate the potential mechanism of this toxicity. To investigate whether ADCs affect neutrophil production from bone marrow, an in vitro assay was developed in which hematopoietic stem cells (HSC) were differentiated to neutrophils. Several antibodies against targets absent in HSCs and neutrophils were conjugated to MMAE via a cleavable valine-citrulline linker (vcMMAE-ADC) or MMAF via a noncleavable maleimidocaproyl linker (mcMMAF-ADC), and their cytotoxicity was tested in the neutrophil differentiation assay. Results showed that HSCs had similar sensitivity to vcMMAE-ADCs and mcMMAF-ADCs; however, vcMMAE-ADCs were more cytotoxic to differentiating neutrophils than the same antibody conjugated to mcMMAF. This inhibitory effect was not mediated by internalization of ADC either by macropinocytosis or FcγRs. Our results suggested that extracellular proteolysis of the cleavable valine-citrulline linker is responsible for the cytotoxicity to differentiating neutrophils. Mass spectrometry analyses indicated that free MMAE was released from vcMMAE-ADCs in the extracellular compartment when they were incubated with differentiating neutrophils or neutrophil conditioned medium, but not with HSC-conditioned medium. Using different protease inhibitors, our data suggested that serine, but not cysteine proteases, were responsible for the cleavage. In vitro experiments demonstrated that the purified serine protease, elastase, was capable of releasing free MMAE from a vcMMAE-ADC. Here we propose that ADCs containing protease cleavable linkers can contribute to neutropenia via extracellular cleavage mediated by serine proteases secreted by differentiating neutrophils in bone marrow. Mol Cancer Ther; 16(9); 1866-76. ©2017 AACR See related article by Zhao et al., p. 1877 . ©2017 American Association for Cancer Research.
Capacitor-Chain Successive-Approximation ADC
NASA Technical Reports Server (NTRS)
Cunningham, Thomas
2003-01-01
A proposed successive-approximation analog-to-digital converter (ADC) would contain a capacitively terminated chain of identical capacitor cells. Like a conventional successive-approximation ADC containing a bank of binary-scaled capacitors, the proposed ADC would store an input voltage on a sample-and-hold capacitor and would digitize the stored input voltage by finding the closest match between this voltage and a capacitively generated sum of binary fractions of a reference voltage (Vref). However, the proposed capacitor-chain ADC would offer two major advantages over a conventional binary-scaled-capacitor ADC: (1) In a conventional ADC that digitizes to n bits, the largest capacitor (representing the most significant bit) must have 2(exp n-1) times as much capacitance, and hence, approximately 2(exp n-1) times as much area as does the smallest capacitor (representing the least significant bit), so that the total capacitor area must be 2(exp n) times that of the smallest capacitor. In the proposed capacitor-chain ADC, there would be three capacitors per cell, each approximately equal to the smallest capacitor in the conventional ADC, and there would be one cell per bit. Therefore, the total capacitor area would be only about 3(exp n) times that of the smallest capacitor. The net result would be that the proposed ADC could be considerably smaller than the conventional ADC. (2) Because of edge effects, parasitic capacitances, and manufacturing tolerances, it is difficult to make capacitor banks in which the values of capacitance are scaled by powers of 2 to the required precision. In contrast, because all the capacitors in the proposed ADC would be identical, the problem of precise binary scaling would not arise.
Sun, Yiqun; Tong, Tong; Cai, Sanjun; Bi, Rui; Xin, Chao; Gu, Yajia
2014-01-01
We elected to analyze the correlation between the pre-treatment apparent diffusion coefficient (ADC) and the clinical, histological, and immunohistochemical status of rectal cancers. Forty-nine rectal cancer patients who received surgical resection without neoadjuvant therapy were selected that underwent primary MRI and diffusion-weighted imaging (DWI). Tumor ADC values were determined and analyzed to identify any correlations between these values and pre-treatment CEA or CA19-9 levels, and/or the histological and immunohistochemical properties of the tumor. Inter-observer agreement of confidence levels from two separate observers was suitable for ADC measurement (k = 0.775). The pre-treatment ADC values of different T stage tumors were not equal (p = 0.003). The overall trend was that higher T stage values correlated with lower ADC values. ADC values were also significantly lower for the following conditions: tumors with the presence of extranodal tumor deposits (p = 0.006) and tumors with CA19-9 levels ≥ 35 g/ml (p = 0.006). There was a negative correlation between Ki-67 LI and the ADC value (r = -0.318, p = 0.026) and between the AgNOR count and the ADC value (r = -0.310, p = 0.030). Significant correlations were found between the pre-treatment ADC values and T stage, extranodal tumor deposits, CA19-9 levels, Ki-67 LI, and AgNOR counts in our study. Lower ADC values were associated with more aggressive tumor behavior. Therefore, the ADC value may represent a useful biomarker for assessing the biological features and possible relationship to the status of identified rectal cancers.
Kishimoto, Keiko; Tajima, Shinya; Maeda, Ichiro; Takagi, Masayuki; Ueno, Takahiko; Suzuki, Nao; Nakajima, Yasuo
2016-08-01
Diffusion-weighted imaging (DWI) and the apparent diffusion coefficient (ADC) are widely used for detecting uterine endometrial cancer. The relationships between ADC values and pathological features of endometrial cancer have not yet been established. To investigate whether ADC values of endometrial cancer vary according to histologic tumor cellularity and tumor grade. We retrospectively reviewed 30 pathologically confirmed endometrial cancers. All patients underwent conventional non-enhanced magnetic resonance imaging (MRI) and DWI procedures, and ADC values were calculated. Tumor cellularity was evaluated by counting cancer cells in three high-power ( × 400) fields. The correlation between ADC values and tumor cellularity was assessed using Pearson's correlation coefficient test for statistical analysis. The mean ± standard deviation (SD) ADC value ( ×10(-3) mm(2)/s) of endometrial cancer was 0.85 ± 0.22 (range, 0.55-1.71). The mean ± SD tumor cellularity was 528.36 ± 16.89 (range, 298.0-763.6). ADC values were significantly inversely correlated with tumor cellularity. No significant relationship was observed between ADC values and tumor grade (mean ADC values: G1, 0.88 ± 0.265 × 10(-3) mm(2)/s; G2, 0.80 ± 0.178 × 10(-3) mm(2)/s; G3, 0.81 ± 0.117 × 10(-3) mm(2)/s). There is a significant inverse relationship between ADC values and tumor cellularity in endometrial cancer. No significant differences in average ADC value were observed between G1, G2, and G3 tumors. However, the lower the tumor grade, the wider the SD. © The Foundation Acta Radiologica 2015.
Karadeli, Elif; Erbay, Gurcan; Parlakgumus, Alper; Koc, Zafer
2018-02-01
To determine the feasibility of diffusion-weighted imaging in evaluation of pancreatic lesions and in differentiation of benign from malignant lesions. Descriptive study. Baskent University Adana Teaching and Research Center, Adana, Turkey, between September 2013 and May 2015. Forty-three lesions [pancreas adenocarcinoma (n=25)], pancreatitis (n=10), benign lesion (n=8)] were utilized with diffusion-weighted magnetic resonance imaging with multiple b-values. Different ADC maps of diffusion weighted images by using b-values were acquired. The median ADC at all b values for malignant lesions was significantly different from that for benign lesions (p<0.001). When ADCs at all b values were compared between benign lesions/normal parenchyma and malignant lesions/normal parenchyma, there was a significant statistical difference in all b values between benign and malignant lesions except at b 50 and b 200 (p<0.05). The lesion/normal parenchyma ADC ratio for b 600 value (AUC=0.804) was more effective than the lesion ADC for b 600 value (AUC=0.766) in differentiation of benign and malignant lesions. The specificity and sensitivity of the lesion/normal parenchyma ADC ratio were higher than those of ADC values of lesions. When the ADC was compared between benign lesions and pancreatitis, a significant difference was found at all b values (p<0.001). There was not a statistically significant difference between the ADC for pancreatitis and that for malignant lesions at any b value combinations (p>0.05). Diffusion-weighted magnetic resonance images can be helpful in differentiation of pancreatic carcinoma and benign lesions. Lesion ADC / normal parenchyma ADC ratios are more important than lesion ADC values in assessment of pancreatic lesions.
Koppa, Santosh; Mohandesi, Manouchehr; John, Eugene
2016-12-01
Power consumption is one of the key design constraints in biomedical devices such as pacemakers that are powered by small non rechargeable batteries over their entire life time. In these systems, Analog to Digital Convertors (ADCs) are used as interface between analog world and digital domain and play a key role. In this paper we present the design of an 8-bit Charge Redistribution Successive Approximation Register (CR-SAR) analog to digital converter in standard TSMC 0.18μm CMOS technology for low power and low data rate devices such as pacemakers. The 8-bit optimized CR-SAR ADC achieves low power of less than 250nW with conversion rate of 1KB/s. This ADC achieves integral nonlinearity (INL) and differential nonlinearity (DNL) less than 0.22 least significant bit (LSB) and less than 0.04 LSB respectively as compared to the standard requirement for the INL and DNL errors to be less than 0.5 LSB. The designed ADC operates at 1V supply voltage converting input ranging from 0V to 250mV.
Diffusion-weighted MR imaging findings of kidneys in patients with early phase of obstruction.
Bozgeyik, Zulkif; Kocakoc, Ercan; Sonmezgoz, Fitnet
2009-04-01
Diffusion-weighted (DW) magnetic resonance (MR) imaging is an MR technique used to show molecular diffusion. The apparent diffusion coefficient (ADC), as a quantitative parameter calculated from the DW MR images. The purpose of this study is to evaluate the ability of DW MR imaging in early phase of obstruction due to urolithiasis. Twenty-six patients with acute dilatation of the pelvicalyceal system detected by intravenous urography were included in this study. MR imaging was performed using a 1.5 T whole-body superconducting MR scanner. DW imaging can be performed using single-shot spin-echo, echo-planar imaging (EPI) sequences with the following diffusion gradient b values: 100, 600, 1000 s/mm(2). Circular region of interest (ROI) was placed in the renal parenchyma for the measurement of ADC values in the normal and obstructed kidney. For statistical analyses, Paired t test were used. In spite of obstructed kidneys had the lower ADC values compared to normal kidneys, these alterations were statistically insignificant. We did not observe significantly different ADC values of early phase of obstructed kidneys compared to normal kidneys.
HVM die yield improvement as a function of DRSEM ADC
NASA Astrophysics Data System (ADS)
Maheshwary, Sonu; Haas, Terry; McGarvey, Steve
2010-03-01
Given the current manufacturing technology roadmap and the competitiveness of the global semiconductor manufacturing environment in conjunction with the semiconductor manufacturing market dynamics, the market place continues to demand a reduced die manufacturing cost. This continuous pressure on lowering die cost in turn drives an aggressive yield learning curve, a key component of which is defect reduction of manufacturing induced anomalies. In order to meet and even exceed line and die yield targets there is a need to revamp defect classification strategies and place a greater emphasize on increasing the accuracy and purity of the Defect Review Scanning Electron Microscope (DRSEM) Automated Defect Classification (ADC) results while placing less emphasis on the ADC results of patterned/un-patterned wafer inspection systems. The increased emphasis on DRSEM ADC results allows for a high degree of automation and consistency in the classification data and eliminates variance induced by the manufacturing staff. This paper examines the use of SEM based Auto Defect Classification in a high volume manufacturing environment as a key driver in the reduction of defect limited yields.
Benchmarking Memory Performance with the Data Cube Operator
NASA Technical Reports Server (NTRS)
Frumkin, Michael A.; Shabanov, Leonid V.
2004-01-01
Data movement across a computer memory hierarchy and across computational grids is known to be a limiting factor for applications processing large data sets. We use the Data Cube Operator on an Arithmetic Data Set, called ADC, to benchmark capabilities of computers and of computational grids to handle large distributed data sets. We present a prototype implementation of a parallel algorithm for computation of the operatol: The algorithm follows a known approach for computing views from the smallest parent. The ADC stresses all levels of grid memory and storage by producing some of 2d views of an Arithmetic Data Set of d-tuples described by a small number of integers. We control data intensity of the ADC by selecting the tuple parameters, the sizes of the views, and the number of realized views. Benchmarking results of memory performance of a number of computer architectures and of a small computational grid are presented.
Multi-model Analysis of Diffusion-weighted Imaging of Normal Testes at 3.0 T: Preliminary Findings.
Min, Xiangde; Feng, Zhaoyan; Wang, Liang; Cai, Jie; Li, Basen; Ke, Zan; Zhang, Peipei; You, Huijuan; Yan, Xu
2018-04-01
This study aimed to establish diffusion quantitative parameters (apparent diffusion coefficient [ADC], DDC, α, D app , and K app ) in normal testes at 3.0 T. Sixty-four healthy volunteers in two age groups (A: 10-39 years; B: ≥ 40 years) underwent diffusion-weighted imaging scanning at 3.0 T. ADC 1000 , ADC 2000 , ADC 3000 , DDC, α, D app , and K app were calculated using the mono-exponential, stretched-exponential, and kurtosis models. The correlations between parameters and the age were analyzed. The parameters were compared between the age groups and between the right and the left testes. The average ADC 1000 , ADC 2000 , ADC 3000 , DDC, α, D app , and K app values did not significantly differ between the right and the left testes (P > .05 for all). The following significant correlations were found: positive correlations between age and testicular ADC 1000 , ADC 2000 , ADC 3000 , DDC, and D app (r = 0.516, 0.518, 0.518, 0.521, and 0.516, respectively; P < .01 for all) and negative correlations between age and testicular α and K app (r = -0.363, -0.427, respectively; P < .01 for both). Compared to group B, in group A, ADC 1000 , ADC 2000 , ADC 3000 , DDC, and D app were significantly lower (P < .05 for all), but α and K app were significantly higher (P < .05 for both). Our study demonstrated the applicability of the testicular mono-exponential, stretched-exponential, and kurtosis models. Our results can help establish a baseline for the normal testicular parameters in these diffusion models. The contralateral normal testis can serve as a suitable reference for evaluating the abnormalities of the other side. The effect of age on these parameters requires further attention. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Kothari, Shweta; Singh, Archana; Das, Utpalendu; Sarkar, Diptendra K; Datta, Chhanda; Hazra, Avijit
2017-01-01
Objective: To evaluate the role of exponential apparent diffusion coefficient (ADC) as a tool for differentiating benign and malignant breast lesions. Patients and Methods: This prospective observational study included 88 breast lesions in 77 patients (between 18 and 85 years of age) who underwent 3T breast magnetic resonance imaging (MRI) including diffusion-weighted imaging (DWI) using b-values of 0 and 800 s/mm2 before biopsy. Mean exponential ADC and ADC of benign and malignant lesions obtained from DWI were compared. Receiver operating characteristics (ROC) curve analysis was undertaken to identify any cut-off for exponential ADC and ADC to predict malignancy. P value of <0.05 was considered statistically significant. Histopathology was taken as the gold standard. Results: According to histopathology, 65 lesions were malignant and 23 were benign. The mean ADC and exponential ADC values of malignant lesions were 0.9526 ± 0.203 × 10−3 mm2/s and 0.4774 ± 0.071, respectively, and for benign lesions were 1.48 ± 0.4903 × 10−3 mm2/s and 0.317 ± 0.1152, respectively. For both the parameters, differences were highly significant (P < 0.001). Cut-off value of ≤0.0011 mm2/s (P < 0.0001) for ADC provided 92.3% sensitivity and 73.9% specificity, whereas with an exponential ADC cut-off value of >0.4 (P < 0.0001) for malignant lesions, 93.9% sensitivity and 82.6% specificity was obtained. The performance of ADC and exponential ADC in distinguishing benign and malignant breast lesions based on respective cut-offs was comparable (P = 0.109). Conclusion: Exponential ADC can be used as a quantitative adjunct tool for characterizing breast lesions with comparable sensitivity and specificity as that of ADC. PMID:28744085
Digital Intermediate Frequency Receiver Module For Use In Airborne Sar Applications
Tise, Bertice L.; Dubbert, Dale F.
2005-03-08
A digital IF receiver (DRX) module directly compatible with advanced radar systems such as synthetic aperture radar (SAR) systems. The DRX can combine a 1 G-Sample/sec 8-bit ADC with high-speed digital signal processor, such as high gate-count FPGA technology or ASICs to realize a wideband IF receiver. DSP operations implemented in the DRX can include quadrature demodulation and multi-rate, variable-bandwidth IF filtering. Pulse-to-pulse (Doppler domain) filtering can also be implemented in the form of a presummer (accumulator) and an azimuth prefilter. An out of band noise source can be employed to provide a dither signal to the ADC, and later be removed by digital signal processing. Both the range and Doppler domain filtering operations can be implemented using a unique pane architecture which allows on-the-fly selection of the filter decimation factor, and hence, the filter bandwidth. The DRX module can include a standard VME-64 interface for control, status, and programming. An interface can provide phase history data to the real-time image formation processors. A third front-panel data port (FPDP) interface can send wide bandwidth, raw phase histories to a real-time phase history recorder for ground processing.
Kim, Boeun; Yi, Kangjae; Jung, Sunyoung; Ji, Seoyeon; Choi, Mincheol; Yoon, Junghee
2014-01-01
Diffusion-weighted imaging (DWI) and apparent diffusion coefficient (ADC) mapping are functional magnetic resonance imaging techniques for detecting water diffusion. DWI and the ADC map were performed for intracranial lesions in two dogs. In necrotizing leukoencephalitis, cavitated lesions contained a hypointense center with a hyperintense periphery on DWI, and hyperintense signals on the ADC maps. In metastatic sarcoma, masses including a necrotic region were hypointense with DWI, and hyperintense on the ADC map with hyperintense perilesional edema on DWI and ADC map. Since DWI and ADC data reflect the altered water diffusion, they can provide additional information at the molecular level.
Sharma, Anurag; Wendland, Rebecca; Sung, Biin; Wu, Wendy; Grunwald, Thomas; Worgall, Stefan
2014-01-01
Respiratory syncytial virus (RSV) is a leading cause of lower respiratory tract disease with high morbidity and mortality in young infants and children. Despite numerous efforts, a licensed vaccine against RSV remains elusive. Since young infants form the primary target group of RSV disease, maternal immunization to boost the protection in neonates is an attractive strategy. In this study we tested the efficacy of maternal immunization with a chimpanzee adenovirus expressing codon-optimized RSV fusion protein (AdC7-Fsyn) to protect infants against RSV infection. Single intranasal immunization of mice by AdC7-Fsyn induced robust anti-RSV systemic and mucosal immunity that protected against RSV without causing vaccine-enhanced RSV disease. RSV humoral immunity was transferred to pups born to immunized mothers that provided protection against RSV. Immunization with AdC7-Fsyn was effective even in the presence of Ad5 preimmunity. The maternally derived immunity was durable with the half-life of 14.63 days that reduced the viral replication up to 15 weeks of age. Notably, the passively immunized mice could be actively re-immunized with AdC7-Fsyn to boost and extend the protection. This substantiates maternal immunization with an AdC7-based vaccine expressing RSV F as feasible approach to protect against RSV early in life. PMID:25171847
Antibody-drug conjugate targeting CD46 eliminates multiple myeloma cells.
Sherbenou, Daniel W; Aftab, Blake T; Su, Yang; Behrens, Christopher R; Wiita, Arun; Logan, Aaron C; Acosta-Alvear, Diego; Hann, Byron C; Walter, Peter; Shuman, Marc A; Wu, Xiaobo; Atkinson, John P; Wolf, Jeffrey L; Martin, Thomas G; Liu, Bin
2016-12-01
Multiple myeloma is incurable by standard approaches because of inevitable relapse and development of treatment resistance in all patients. In our prior work, we identified a panel of macropinocytosing human monoclonal antibodies against CD46, a negative regulator of the innate immune system, and constructed antibody-drug conjugates (ADCs). In this report, we show that an anti-CD46 ADC (CD46-ADC) potently inhibited proliferation in myeloma cell lines with little effect on normal cells. CD46-ADC also potently eliminated myeloma growth in orthometastatic xenograft models. In primary myeloma cells derived from bone marrow aspirates, CD46-ADC induced apoptosis and cell death, but did not affect the viability of nontumor mononuclear cells. It is of clinical interest that the CD46 gene resides on chromosome 1q, which undergoes genomic amplification in the majority of relapsed myeloma patients. We found that the cell surface expression level of CD46 was markedly higher in patient myeloma cells with 1q gain than in those with normal 1q copy number. Thus, genomic amplification of CD46 may serve as a surrogate for target amplification that could allow patient stratification for tailored CD46-targeted therapy. Overall, these findings indicate that CD46 is a promising target for antibody-based treatment of multiple myeloma, especially in patients with gain of chromosome 1q.
Ghosh, Adarsh; Singh, Tulika; Singla, Veenu; Bagga, Rashmi; Khandelwal, Niranjan
2017-12-01
Apparent diffusion coefficient (ADC) maps are usually generated by builtin software provided by the MRI scanner vendors; however, various open-source postprocessing software packages are available for image manipulation and parametric map generation. The purpose of this study is to establish the reproducibility of absolute ADC values obtained using different postprocessing software programs. DW images with three b values were obtained with a 1.5-T MRI scanner, and the trace images were obtained. ADC maps were automatically generated by the in-line software provided by the vendor during image generation and were also separately generated on postprocessing software. These ADC maps were compared on the basis of ROIs using paired t test, Bland-Altman plot, mountain plot, and Passing-Bablok regression plot. There was a statistically significant difference in the mean ADC values obtained from the different postprocessing software programs when the same baseline trace DW images were used for the ADC map generation. For using ADC values as a quantitative cutoff for histologic characterization of tissues, standardization of the postprocessing algorithm is essential across processing software packages, especially in view of the implementation of vendor-neutral archiving.
Arginine Decarboxylase Is Localized in Chloroplasts.
Borrell, A.; Culianez-Macia, F. A.; Altabella, T.; Besford, R. T.; Flores, D.; Tiburcio, A. F.
1995-01-01
Plants, unlike animals, can use either ornithine decarboxylase or arginine decarboxylase (ADC) to produce the polyamine precursor putrescine. Lack of knowledge of the exact cellular and subcellular location of these enzymes has been one of the main obstacles to our understanding of the biological role of polyamines in plants. We have generated polyclonal antibodies to oat (Avena sativa L.) ADC to study the spatial distribution and subcellular localization of ADC protein in different oat tissues. By immunoblotting and immunocytochemistry, we show that ADC is organ specific. By cell fractionation and immunoblotting, we show that ADC is localized in chloroplasts associated with the thylakoid membrane. The results also show that increased levels of ADC protein are correlated with high levels of ADC activity and putrescine in osmotically stressed oat leaves. A model of compartmentalization for the arginine pathway and putrescine biosynthesis in active photosynthetic tissues has been proposed. In the context of endosymbiote-driven metabolic evolution in plants, the location of ADC in the chloroplast compartment may have major evolutionary significance, since it explains (a) why plants can use two alternative pathways for putrescine biosynthesis and (b) why animals do not possess ADC. PMID:12228631
Li, Xiaoxia; Yuan, Ying; Ren, Jiliang; Shi, Yiqian; Tao, Xiaofeng
2018-03-26
We aimed to investigate the incremental prognostic value of apparent diffusion coefficient (ADC) histogram analysis in patients with head and neck squamous cell carcinoma (HNSCC) and integrate it into a multivariate prognostic model. A retrospective review of magnetic resonance imaging findings was conducted in patients with pathologically confirmed HNSCC between June 2012 and December 2015. For each tumor, six histogram parameters were derived: the 10th, 50th, and 90th percentiles of ADC (ADC 10 , ADC 50 , and ADC 90 ); mean ADC values (ADC mean ); kurtosis; and skewness. The clinical variables included age, sex, smoking status, tumor volume, and tumor node metastasis stage. The association of these histogram and clinical variables with overall survival (OS) was determined. Further validation of the histogram parameters as independent biomarkers was performed using multivariate Cox proportional hazard models combined with clinical variables, which was compared to the clinical model. Models were assessed with C index and receiver operating characteristic curve analyses for the 12- and 36-month OS. Ninety-six patients were eligible for analysis. Median follow-up was 877 days (range, 54-1516 days). A total of 29 patients died during follow-up (30%). Patients with higher ADC values (ADC 10 > 0.958 × 10 -3 mm 2 /s, ADC 50 > 1.089 × 10 -3 mm 2 /s, ADC 90 > 1.152 × 10 -3 mm 2 /s, ADC mean > 1.047 × 10 -3 mm 2 /s) and lower kurtosis (≤0.967) were significant predictors of poor OS (P < .100 for all). After adjusting for sex and tumor node metastasis stage, the ADC 90 and kurtosis are both significant predictors of OS with hazard ratios = 1.00 (95% confidence interval: 1.001-1.004) and 0.58 (95% confidence interval: 0.37-0.90), respectively. By adding the ADC parameters into the clinical model, the C index and diagnostic accuracies for the 12- and 36-month OS showed significant improvement. ADC histogram analysis has incremental prognostic value in patients with HNSCC and increases the performance of a multivariable prognostic model in addition to clinical variables. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Gupta, Rajan T; Kauffman, Christopher R; Garcia-Reyes, Kirema; Palmeri, Mark L; Madden, John F; Polascik, Thomas J; Rosenkrantz, Andrew B
2015-08-01
The apparent diffusion coefficient (ADC) values for benign central zone (CZ) of the prostate were compared with ADC values of benign peripheral zone (PZ), benign transition zone (TZ), and prostate cancer, using histopathologic findings from radical prostatectomy as the reference standard. The study included 27 patients with prostate cancer (mean [± SD] age, 60.0 ± 7.6 years) who had 3-T endorectal coil MRI of the prostate performed before undergoing prostatectomy with whole-mount histopathologic assessment. Mean ADC values were recorded from the ROI within the index tumor and within benign CZ, PZ, and TZ, with the use of histopathologic findings as the reference standard. ADC values of the groups were compared using paired t tests and ROC curve analysis. The ADC of benign CZ in the right (1138 ± 123 × 10(-6) mm(2)/s) and left (1166 ± 141 × 10(-6) mm(2)/s) lobes was not significantly different (p = 0.217). However, the ADC of benign CZ (1154 ± 129 × 10(-6) mm(2)/s) was significantly lower (p < 0.001) than the ADCs of benign PZ (1579 ± 197 × 10(-6) mm(2)/s) and benign TZ (1429 ± 180 × 10(-6) mm(2)/s). Although the ADC of index tumors (1042 ± 134 × 10(-6) mm(2)/s) was significantly lower (p = 0.002) than the ADC of benign CZ there was no significant difference (p = 0.225) between benign CZ and tumors with a Gleason score of 6 (1119 ± 87 × 10(-6) mm(2)/s). In 22.2% of patients (6/27), including five patients who had tumors with a Gleason score greater than 6, the ADC was lower in benign CZ than in the index tumor. The AUC of ADC for the differentiation of benign CZ from index tumors was 72.4% (sensitivity, 70.4%; specificity, 51.9%), and the AUC of ADC for differentiation from tumors with a Gleason score greater than 6 was 76.7% (sensitivity, 75.0%; specificity, 65.0%). The ADC of benign CZ is lower than the ADC of other zones of the prostate and overlaps with the ADC of prostate cancer tissue, including high-grade tumors. Awareness of this potential diagnostic pitfall is important to avoid misinterpreting the normal CZ as suspicious for tumor.
A 9-Bit 50 MSPS Quadrature Parallel Pipeline ADC for Communication Receiver Application
NASA Astrophysics Data System (ADS)
Roy, Sounak; Banerjee, Swapna
2018-03-01
This paper presents the design and implementation of a pipeline Analog-to-Digital Converter (ADC) for superheterodyne receiver application. Several enhancement techniques have been applied in implementing the ADC, in order to relax the target specifications of its building blocks. The concepts of time interleaving and double sampling have been used simultaneously to enhance the sampling speed and to reduce the number of amplifiers used in the ADC. Removal of a front end sample-and-hold amplifier is possible by employing dynamic comparators with switched capacitor based comparison of input signal and reference voltage. Each module of the ADC comprises two 2.5-bit stages followed by two 1.5-bit stages and a 3-bit flash stage. Four such pipeline ADC modules are time interleaved using two pairs of non-overlapping clock signals. These two pairs of clock signals are in phase quadrature with each other. Hence the term quadrature parallel pipeline ADC has been used. These configurations ensure that the entire ADC contains only eight operational-trans-conductance amplifiers. The ADC is implemented in a 0.18-μm CMOS process and supply voltage of 1.8 V. The proto-type is tested at sampling frequencies of 50 and 75 MSPS producing an Effective Number of Bits (ENOB) of 6.86- and 6.11-bits respectively. At peak sampling speed, the core ADC consumes only 65 mW of power.
A 9-Bit 50 MSPS Quadrature Parallel Pipeline ADC for Communication Receiver Application
NASA Astrophysics Data System (ADS)
Roy, Sounak; Banerjee, Swapna
2018-06-01
This paper presents the design and implementation of a pipeline Analog-to-Digital Converter (ADC) for superheterodyne receiver application. Several enhancement techniques have been applied in implementing the ADC, in order to relax the target specifications of its building blocks. The concepts of time interleaving and double sampling have been used simultaneously to enhance the sampling speed and to reduce the number of amplifiers used in the ADC. Removal of a front end sample-and-hold amplifier is possible by employing dynamic comparators with switched capacitor based comparison of input signal and reference voltage. Each module of the ADC comprises two 2.5-bit stages followed by two 1.5-bit stages and a 3-bit flash stage. Four such pipeline ADC modules are time interleaved using two pairs of non-overlapping clock signals. These two pairs of clock signals are in phase quadrature with each other. Hence the term quadrature parallel pipeline ADC has been used. These configurations ensure that the entire ADC contains only eight operational-trans-conductance amplifiers. The ADC is implemented in a 0.18-μm CMOS process and supply voltage of 1.8 V. The proto-type is tested at sampling frequencies of 50 and 75 MSPS producing an Effective Number of Bits (ENOB) of 6.86- and 6.11-bits respectively. At peak sampling speed, the core ADC consumes only 65 mW of power.
Zhao, Hua; Xu, Can; Luo, Xiaoli; Wei, Feng; Wang, Ning; Shi, Huiying; Ren, Xiubao
2018-01-01
Since the preclinical results about chimpanzee adenovirus serotype-68 (AdC68)-based vaccine showed an encouraging results, it reminded us that AdC68 may be a suitable cancer vaccine vector. Previous study indicated that the seroprevalence of neutralizing antibodies (NAbs) against adenovirus was different between cancer patients and healthy volunteers. Knowledge regarding the prevalence rates of AdC68 NAbs for cancer patients is lacking. Therefore, assessing the preexistence of NAbs against AdC68 in cancer patients could provide useful insights for developing future AdC68-based cancer vaccines. In this study, 440 patients with different pathological types of tumors and 204 healthy adult volunteers were enrolled to evaluate the NAbs against AdC68 and human adenovirus serotype-5 (AdHu5). The seroprevalence of NAbs against AdC68 was much lower than that against AdHu5 in cancer subjects (43.64 vs. 67.05%, P < 0.01). The seroprevalence rates of NAbs to AdC68 in the cancer subjects were statistically higher than those detected in the healthy adult volunteers (43.64 vs. 23.53%, P = 0.000). The seroprevalence rates of AdC68 NAbs were much lower in lung, laryngeal, esophageal, and cervical cancer patients compared with oropharyngeal, colon, and rectal cancer patients. Furthermore, the seroprevalence rates of AdC68 NAbs were much lower in lung adenocarcinoma patients than in lung squamous cell carcinoma patients (35.00 vs. 70.00%, P < 0.05). No significant difference in the AdC68 NAbs among patients with different clinical stages of cancer was detected. The percentage of NAbs against AdC68 was significantly lower than that against AdHu5 ( P < 0.05) in stage-I, -II, and -III cancer patients. No significant difference between the percentage of NAbs against AdC68 and AdHu5 in the subjects with stage-IV cancer was detected. The study also demonstrated the distribution of AdHu5 and AdC68 NAb titers for the positive samples. It showed that very low NAb titers against AdC68 with respect to AdHu5 in both healthy subjects and cancer subjects, especially in lung, laryngeal, esophageal, gastric, and cervical carcinomas. Also, the titer of NAbs against AdC68 was significantly lower than that against AdHu5 in the same clinical stage and age group ( P < 0.05). Taken together, the present study showed that NAbs against AdC68 is much lower than AdHu5, especially in lung adenocarcinoma, laryngeal cancer, esophageal cancer, and cervical cancer patients. These results provided strong support for candidating AdC68 as a suitable vector of cancer vaccines.
Barral, M; Soyer, P; Ben Hassen, W; Gayat, E; Aout, M; Chiaradia, M; Rahmouni, A; Luciani, A
2013-04-01
To evaluate reproducibility and variations in apparent diffusion coefficient (ADC) measurement in normal pancreatic parenchyma at 1.5- and 3.0-Tesla and determine if differences may exist between the four pancreatic segments. Diffusion-weighted MR imaging of the pancreas was performed at 1.5-Tesla in 20 patients and at 3.0-Tesla in other 20 patients strictly matched for gender and age using the same b values (0, 400 and 800s/mm(2)). Two independent observers placed regions of interest within the four pancreatic segments to measure ADC at both fields. Intra- and inter-observer agreement in ADC measurement was assessed using Bland-Altman analysis and comparison between ADC values obtained at both fields using non-parametrical tests. There were no significant differences in ADC between repeated measurements and between ADC obtained at 1.5-Tesla and those at 3.0-Tesla. The 95% limits of intra-observer agreement between ADC were 2.3%-22.7% at 1.5-Tesla and 1%-24.2% at 3.0-Tesla and those for inter-observer agreement between 1.9%-14% at 1.5-Tesla and 8%-25% at 3.0-Tesla. ADC values were similar in all pancreatic segments at 3.0-T whereas the tail had lower ADC at 1.5-Tesla. ADC measurement conveys high degrees of intra- and inter-observer reproducibility. ADC have homogeneous distribution among the four pancreatic segments at 3.0-Tesla. Copyright © 2012 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Winfield, Jessica M; Poillucci, Gabriele; Blackledge, Matthew D; Collins, David J; Shah, Vallari; Tunariu, Nina; Kaiser, Martin F; Messiou, Christina
2018-04-01
The aim of this study was to identify apparent diffusion coefficient (ADC) values for typical haemangiomas in the spine and to compare them with active malignant focal deposits. This was a retrospective single-institution study. Whole-body magnetic resonance imaging (MRI) scans of 106 successive patients with active multiple myeloma, metastatic prostate or breast cancer were analysed. ADC values of typical vertebral haemangiomas and malignant focal deposits were recorded. The ADC of haemangiomas (72 ROIs, median ADC 1,085×10 -6 mm 2 s -1 , interquartile range 927-1,295×10 -6 mm 2 s -1 ) was significantly higher than the ADC of malignant focal deposits (97 ROIs, median ADC 682×10 -6 mm 2 s -1 , interquartile range 583-781×10 -6 mm 2 s -1 ) with a p-value < 10 -6 . Receiver operating characteristic (ROC) analysis produced an area under the curve of 0.93. An ADC threshold of 872×10 -6 mm 2 s -1 separated haemangiomas from malignant focal deposits with a sensitivity of 84.7 % and specificity of 91.8 %. ADC values of classical vertebral haemangiomas are significantly higher than malignant focal deposits. The high ADC of vertebral haemangiomas allows them to be distinguished visually and quantitatively from active sites of disease, which show restricted diffusion. • Whole-body diffusion-weighted MRI is becoming widely used in myeloma and bone metastases. • ADC values of vertebral haemangiomas are significantly higher than malignant focal deposits. • High ADCs of haemangiomas allows them to be distinguished from active disease.
NASA Astrophysics Data System (ADS)
Yathapu, Nithin; McGarvey, Steve; Brown, Justin; Zhivotovsky, Alexander
2016-03-01
This study explores the feasibility of Automated Defect Classification (ADC) with a Surface Scanning Inspection System (SSIS). The defect classification was based upon scattering sensitivity sizing curves created via modeling of the Bidirectional Reflectance Distribution Function (BRDF). The BRDF allowed for the creation of SSIS sensitivity/sizing curves based upon the optical properties of both the filmed wafer samples and the optical architecture of the SSIS. The elimination of Polystyrene Latex Sphere (PSL) and Silica deposition on both filmed and bare Silicon wafers prior to SSIS recipe creation and ADC creates a challenge for light scattering surface intensity based defect binning. This study explored the theoretical maximal SSIS sensitivity based on native defect recipe creation in conjunction with the maximal sensitivity derived from BRDF modeling recipe creation. Single film and film stack wafers were inspected with recipes based upon BRDF modeling. Following SSIS recipe creation, initially targeting maximal sensitivity, selected recipes were optimized to classify defects commonly found on non-patterned wafers. The results were utilized to determine the ADC binning accuracy of the native defects and evaluate the SSIS recipe creation methodology. A statistically valid sample of defects from the final inspection results of each SSIS recipe and filmed substrate were reviewed post SSIS ADC processing on a Defect Review Scanning Electron Microscope (SEM). Native defect images were collected from each statistically valid defect bin category/size for SEM Review. The data collected from the Defect Review SEM was utilized to determine the statistical purity and accuracy of each SSIS defect classification bin. This paper explores both, commercial and technical, considerations of the elimination of PSL and Silica deposition as a precursor to SSIS recipe creation targeted towards ADC. Successful integration of SSIS ADC in conjunction with recipes created via BRDF modeling has the potential to dramatically reduce the workload requirements of a Defect Review SEM and save a significant amount of capital expenditure for 450mm SSIS recipe creation.
Pink-Beam, Highly-Accurate Compact Water Cooled Slits
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lyndaker, Aaron; Deyhim, Alex; Jayne, Richard
2007-01-19
Advanced Design Consulting, Inc. (ADC) has designed accurate compact slits for applications where high precision is required. The system consists of vertical and horizontal slit mechanisms, a vacuum vessel which houses them, water cooling lines with vacuum guards connected to the individual blades, stepper motors with linear encoders, limit (home position) switches and electrical connections including internal wiring for a drain current measurement system. The total slit size is adjustable from 0 to 15 mm both vertically and horizontally. Each of the four blades are individually controlled and motorized. In this paper, a summary of the design and Finite Elementmore » Analysis of the system are presented.« less
TORMES-BEXUS 17 and 19: Precursor of the 6U CubeSat 3CAT-2
NASA Astrophysics Data System (ADS)
Carreno-Luengo, H.; Amezaga, A.; Bolet, A.; Vidal, D.; Jane, J.; Munoz, J. F.; Olive, R.; Camps, A.; Carola, J.; Catarino, N.; Hagenfeldt, M.; Palomo, P.; Cornara, S.
2015-09-01
3Cat-2 Assembly, Integration and Verification (AIV) activities of the Engineering Model (EM) and the Flight Model (FM) are being carried out at present. The Attitude Determination and Control System (ADCS) and Flight Software (FSW) validation campaigns will be performed at Universitat Politècnica de Catalunya (UPC) during the incomings months. An analysis and verification of the 3Cat-2 key mission requirements has been performed. The main results are summarized in this work.
Accurate estimation of camera shot noise in the real-time
NASA Astrophysics Data System (ADS)
Cheremkhin, Pavel A.; Evtikhiev, Nikolay N.; Krasnov, Vitaly V.; Rodin, Vladislav G.; Starikov, Rostislav S.
2017-10-01
Nowadays digital cameras are essential parts of various technological processes and daily tasks. They are widely used in optics and photonics, astronomy, biology and other various fields of science and technology such as control systems and video-surveillance monitoring. One of the main information limitations of photo- and videocameras are noises of photosensor pixels. Camera's photosensor noise can be divided into random and pattern components. Temporal noise includes random noise component while spatial noise includes pattern noise component. Temporal noise can be divided into signal-dependent shot noise and signal-nondependent dark temporal noise. For measurement of camera noise characteristics, the most widely used methods are standards (for example, EMVA Standard 1288). It allows precise shot and dark temporal noise measurement but difficult in implementation and time-consuming. Earlier we proposed method for measurement of temporal noise of photo- and videocameras. It is based on the automatic segmentation of nonuniform targets (ASNT). Only two frames are sufficient for noise measurement with the modified method. In this paper, we registered frames and estimated shot and dark temporal noises of cameras consistently in the real-time. The modified ASNT method is used. Estimation was performed for the cameras: consumer photocamera Canon EOS 400D (CMOS, 10.1 MP, 12 bit ADC), scientific camera MegaPlus II ES11000 (CCD, 10.7 MP, 12 bit ADC), industrial camera PixeLink PL-B781F (CMOS, 6.6 MP, 10 bit ADC) and video-surveillance camera Watec LCL-902C (CCD, 0.47 MP, external 8 bit ADC). Experimental dependencies of temporal noise on signal value are in good agreement with fitted curves based on a Poisson distribution excluding areas near saturation. Time of registering and processing of frames used for temporal noise estimation was measured. Using standard computer, frames were registered and processed during a fraction of second to several seconds only. Also the accuracy of the obtained temporal noise values was estimated.
NASA Technical Reports Server (NTRS)
Luna, Michael E.; Collins, Stephen M.
2011-01-01
On November 4, 2010 the already "in-flight" Deep Impact spacecraft flew within 700km of comet 103P/Hartley 2 as part of its extended mission EPOXI, the 5th time to date any spacecraft visited a comet. In 2005, the spacecraft had previously imaged a probe impact comet Tempel 1. The EPOXI flyby marked the first time in history that two comets were explored with the same instruments on a re-used spacecraft-with hardware and software originally designed and optimized for a different mission. This made the function of the attitude determination and control subsystem (ADCS) critical to the successful execution of the EPOXI flyby. As part of the spacecraft team preparations, the ADCS team had to perform thorough sequence reviews, key spacecraft activities and onboard calibrations. These activities included: review of background sequences for the initial conditions vector, sun sensor coefficients, and reaction wheel assembly (RWA) de-saturations; design and execution of 10 trajectory correction maneuvers; science calibration of the two telescope instruments; a flight demonstration of the fastest turns conducted by the spacecraft between Earth and comet point; and assessment of RWA health (given RWA problems on other spacecraft).
Hardie, Andrew D; Egbert, Robert E; Rissing, Michael S
2015-01-01
Diffusion-weighted magnetic resonance imaging (DW-MR) can be useful in the differentiation of hemangiomata from liver metastasis, but improved methods other than by mean apparent diffusion coefficient (mADC) are needed. A retrospective review identified 109 metastatic liver lesions and 86 hemangiomata in 128 patients who had undergone DW-MR. For each lesion, mADC and the standard deviation of the mean ADC (sdADC) were recorded and compared by receiver operating characteristic analysis. Mean mADC was higher in benign hemangiomata (1.52±0.12 mm(2)/s) than in liver metastases (1.33±0.18 mm(2)/s), but there was significant overlap in values. The mean sdADC was lower in hemangiomata (101±17 mm(2)/s) than metastases (245±25 mm(2)/s) and demonstrated no overlap in values, which was significantly different (P<.0001). Hemangiomata may be better able to be differentiated from liver metastases on the basis of sdADC than by mADC, although further studies are needed. Copyright © 2015 Elsevier Inc. All rights reserved.
Antibody drug conjugates - Trojan horses in the war on cancer.
Iyer, U; Kadambi, V J
2011-01-01
Antibody drug conjugates (ADCs) consist of an antibody attached to a cytotoxic drug by means of a linker. ADCs provide a way to couple the specificity of a monoclonal antibody (mAb) to the cytotoxicity of a small-molecule drug and, therefore, are promising new therapies for cancer. ADCs are prodrugs that are inactive in circulation but exert their cytotoxicity upon binding to the target cancer cell. Earlier unsuccessful attempts to generate ADCs with therapeutic value have emphasized the important role each component plays in determining the efficacy and safety of the final ADC. Scientific advances in engineering antibodies for maximum efficacy as anticancer agents, identification of highly cytotoxic molecules, and generation of linkers with increased stability in circulation have all contributed to the development of the many ADCs that are currently in clinical trials. This review discusses parameters that guide the selection of the components of an ADC to increase its therapeutic window, provides a brief look at ADCs currently in clinical trials, and discusses future challenges in this field. Copyright © 2011. Published by Elsevier Inc.
Localization of arginine decarboxylase in tobacco plants.
Bortolotti, Cristina; Cordeiro, Alexandra; Alcázar, Rubén; Borrell, Antoni; Culiañez-Macià, Francisco A.; Tiburcio, Antonio F.; Altabella, Teresa
2004-01-01
The lack of knowledge about the tissue and subcellular distribution of polyamines (PAs) and the enzymes involved in their metabolism remains one of the main obstacles in our understanding of the biological role of PAs in plants. Arginine decarboxylase (ADC; EC 4.1.1.9) is a key enzyme in polyamine biosynthesis in plants. We have characterized a cDNA coding for ADC from Nicotiana tabacum L. cv. Petit Havana SR1. The deduced ADC polypeptide had 721 amino acids and a molecular mass of 77 kDa. The ADC cDNA was overexpressed in Escherichia coli, and the ADC fusion protein obtained was used to produce polyclonal antibodies. Using immunological methods, we demonstrate the presence of the ADC protein in all plant organs analysed: flowers, seeds, stems, leaves and roots. Moreover, depending on the tissue, the protein is localized in two different subcellular compartments, the nucleus and the chloroplast. In photosynthetic tissues, ADC is located mainly in chloroplasts, whereas in non-photosynthetic tissues the protein appears to be located in nuclei. The different compartmentation of ADC may be related to distinct functions of the protein in different cell types.
A potential risk of overestimating apparent diffusion coefficient in parotid glands.
Liu, Yi-Jui; Lee, Yi-Hsiung; Chang, Hing-Chiu; Huang, Teng-Yi; Chiu, Hui-Chu; Wang, Chih-Wei; Chiou, Ta-Wei; Hsu, Kang; Juan, Chun-Jung; Huang, Guo-Shu; Hsu, Hsian-He
2015-01-01
To investigate transient signal loss on diffusion weighted images (DWI) and overestimation of apparent diffusion coefficient (ADC) in parotid glands using single shot echoplanar DWI (EPDWI). This study enrolled 6 healthy subjects and 7 patients receiving radiotherapy. All participants received dynamic EPDWI with a total of 8 repetitions. Imaging quality of DWI was evaluated. Probability of severe overestimation of ADC (soADC), defined by an ADC ratio more than 1.2, was calculated. Error on T2WI, DWI, and ADC was computed. Statistical analysis included paired Student t testing and Mann-Whitney U test. A P value less than 0.05 was considered statistically significant. Transient signal loss was visually detected on some excitations of DWI but not on T2WI or mean DWI. soADC occurred randomly among 8 excitations and 3 directions of diffusion encoding gradients. Probability of soADC was significantly higher in radiotherapy group (42.86%) than in healthy group (24.39%). The mean error percentage decreased as the number of excitations increased on all images, and, it was smallest on T2WI, followed by DWI and ADC in an increasing order. Transient signal loss on DWI was successfully detected by dynamic EPDWI. The signal loss on DWI and overestimation of ADC could be partially remedied by increasing the number of excitations.
Zolal, Amir; Juratli, Tareq A; Linn, Jennifer; Podlesek, Dino; Sitoci Ficici, Kerim Hakan; Kitzler, Hagen H; Schackert, Gabriele; Sobottka, Stephan B; Rieger, Bernhard; Krex, Dietmar
2016-05-01
Objective To determine the value of apparent diffusion coefficient (ADC) histogram parameters for the prediction of individual survival in patients undergoing surgery for recurrent glioblastoma (GBM) in a retrospective cohort study. Methods Thirty-one patients who underwent surgery for first recurrence of a known GBM between 2008 and 2012 were included. The following parameters were collected: age, sex, enhancing tumor size, mean ADC, median ADC, ADC skewness, ADC kurtosis and fifth percentile of the ADC histogram, initial progression free survival (PFS), extent of second resection and further adjuvant treatment. The association of these parameters with survival and PFS after second surgery was analyzed using log-rank test and Cox regression. Results Using log-rank test, ADC histogram skewness of the enhancing tumor was significantly associated with both survival (p = 0.001) and PFS after second surgery (p = 0.005). Further parameters associated with prolonged survival after second surgery were: gross total resection at second surgery (p = 0.026), tumor size (0.040) and third surgery (p = 0.003). In the multivariate Cox analysis, ADC histogram skewness was shown to be an independent prognostic factor for survival after second surgery. Conclusion ADC histogram skewness of the enhancing lesion, enhancing lesion size, third surgery, as well as gross total resection have been shown to be associated with survival following the second surgery. ADC histogram skewness was an independent prognostic factor for survival in the multivariate analysis.
Bae, Hyeyeol; Yoshida, Soichiro; Matsuoka, Yoh; Nakajima, Hiroshi; Ito, Eisaku; Tanaka, Hiroshi; Oya, Miyako; Nakayama, Takayuki; Takeshita, Hideki; Kijima, Toshiki; Ishioka, Junichiro; Numao, Noboru; Koga, Fumitaka; Saito, Kazutaka; Akashi, Takumi; Fujii, Yasuhisa; Kihara, Kazunori
2014-03-01
To assess whether there is an association between the apparent diffusion coefficient (ADC) value and the pathological characteristics of prostate cancer. The study cohort consisted of 29 consecutive patients with prostate cancer treated with radical prostatectomy. All patients underwent diffusion-weighted MRI before the prostate biopsy. In 42 tumor foci, the associations of the ADC values with the clinicopathological characteristics and Ki-67 labeling index (LI) were analyzed. High-grade cancers (Gleason score [GS] ≥ 4 + 3), larger cancers (maximum diameter (MD) ≥ 16 mm), and highly proliferating cancers (Ki-67 LI ≥ 4.43 %) had significantly lower ADC values, respectively (P < .001, P = .008, and P = .044, respectively). There was no significant difference in ADC value according to age, prostate-specific antigen, presence of extra-prostatic extension, and intra-tumoral stroma proportion. Multivariate analysis showed that GS, Ki-67 LI, and MD had independent and significant correlations with ADC value (P < .001, P = .006, and P = .002, respectively). Low ADC tumors (<0.52 × 10(-3) mm(2)/s) are likely to be high-grade cancer foci compared with high ADC tumors (relative risk: 65.2). The sensitivity and specificity of the ADC value to predict high-grade cancer foci are 81.8 and 93.5 %, respectively. A low ADC value reflects the morphological and biological features of prostate cancer. Analyzing the ADC value may make it possible to more precisely predict the cancer aggressiveness of each focus before treatment.
Li, Anqin; Xing, Wei; Li, Haojie; Hu, Yao; Hu, Daoyu; Li, Zhen; Kamel, Ihab R
2018-05-29
The purpose of this article is to evaluate the utility of volumetric histogram analysis of apparent diffusion coefficient (ADC) derived from reduced-FOV DWI for small (≤ 4 cm) solid renal mass subtypes at 3-T MRI. This retrospective study included 38 clear cell renal cell carcinomas (RCCs), 16 papillary RCCs, 18 chromophobe RCCs, 13 minimal fat angiomyolipomas (AMLs), and seven oncocytomas evaluated with preoperative MRI. Volumetric ADC maps were generated using all slices of the reduced-FOV DW images to obtain histogram parameters, including mean, median, 10th percentile, 25th percentile, 75th percentile, 90th percentile, and SD ADC values, as well as skewness, kurtosis, and entropy. Comparisons of these parameters were made by one-way ANOVA, t test, and ROC curves analysis. ADC histogram parameters differentiated eight of 10 pairs of renal tumors. Three subtype pairs (clear cell RCC vs papillary RCC, clear cell RCC vs chromophobe RCC, and clear cell RCC vs minimal fat AML) were differentiated by mean ADC. However, five other subtype pairs (clear cell RCC vs oncocytoma, papillary RCC vs minimal fat AML, papillary RCC vs oncocytoma, chromophobe RCC vs minimal fat AML, and chromophobe RCC vs oncocytoma) were differentiated by histogram distribution parameters exclusively (all p < 0.05). Mean ADC, median ADC, 75th and 90th percentile ADC, SD ADC, and entropy of malignant tumors were significantly higher than those of benign tumors (all p < 0.05). Combination of mean ADC with histogram parameters yielded the highest AUC (0.851; sensitivity, 80.0%; specificity, 86.1%). Quantitative volumetric ADC histogram analysis may help differentiate various subtypes of small solid renal tumors, including benign and malignant lesions.
Scrascia, Federica; Quattrocchi, Carlo Cosimo; Errante, Yuri; Gangemi, Emma; Curcio, Giuseppe; Ursini, Francesca; Silvestrini, Mauro; Maggio, Paola; Beomonte Zobel, Bruno; Rossini, Paolo Maria; Pasqualetti, Patrizio; Falsetti, Lorenzo; Vernieri, Fabrizio
2016-01-01
Background and Purpose An increase in brain water diffusivity as measured using magnetic resonance imaging (MRI) has been recently reported in normal-appearing white matter (NAWM) in patients affected by cognitive impairment. However, it remains to be clarified if this reflects an overt neuronal tissue disruption that leads to degenerative or microvascular lesions. This question was addressed by comparing the regional MRI apparent diffusion coefficients (ADCs) of NAWM in patients affected by Alzheimer's disease (AD) or vascular dementia (VaD). The relationships of ADCs with the white-matter hyperintensity (WMH) burden, carotid atherosclerosis, and cognitive performance were also investigated. Methods Forty-nine AD and 31 VaD patients underwent brain MRI to assess the WMH volume and regional NAWM ADCs, neuropsychological evaluations, and carotid ultrasound to assess the plaque severity and intima-media thickness (IMT). Results Regional ADCs in NAWM did not differ between VaD and AD patients, while the WMH volume was greater in VaD than in AD patients. The ADC in the anterior corpus callosum was related to the WMH volume, while a greater carotid IMT was positively correlated with the temporal ADC and WMH volume. The memory performance was worse in patients with higher temporal ADCs. Constructional praxis scores were related to ADCs in the frontal, and occipital lobes, in the anterior and posterior corpus callosum as well as to the WMH volume. Abstract reasoning was related to frontal, parietal, and temporal ADCs. Conclusions Our data show that higher regional ADCs in NAWM are associated with microcirculatory impairment, as depicted by the WMH volume. Moreover, regional ADCs in NAWM are differently associated with the neuropsychological performances in memory, constructional praxia, and abstract reasoning domains. PMID:27074295
Wang, Xue; Zhao, Yu; Hu, Yumin; Zhou, Yongjin; Ye, Xinjian; Liu, Kun; Bai, Guanghui; Guo, Anna; Du, Meimei; Jiang, Lezhen; Wang, Jinhong; Yan, Zhihan
2017-07-11
Previous researchers obtained various apparent diffusion coefficient (ADC) cutoff values to differentiate endometrial carcinoma from benign mimickers with 1.5T magnetic resonance imaging (MRI). Few studies have used 3T MRI or validated the effectiveness of these cutoff ADC values prospectively. This study was designed in two stages to obtain a cutoff ADC value at 3T MRI and to validate prospectively the role of the ADC value. First, we conducted a retrospective study of 60 patients to evaluate the diagnostic value of ADC by obtain a theoretical cutoff ADC value for differentiating between benign and malignant endometrial lesions. Student's t test revealed that ADC values for stage I endometrial carcinomas were significantly lower than those for benign lesions. The area under the curve value of the receiver operating characteristic curve was 0.993, and the cutoff ADC value was 0.98 × 10-3 mm2/s. The sensitivity, specificity, and overall accuracy of diagnosing stage I endometrial carcinoma were 100%, 97.1%, and 98.3%, respectively. Second, we conducted a prospective study of 26 patients to validate the use of the cutoff ADC value obtained in the study's first stage. The sensitivity, specificity, and overall accuracy for differentiating malignant from benign endometrial lesions based on the cutoff ADC value obtained earlier were as follows: radiologist 1 attained 86.67%, 100.0%, and 92.31%, respectively; radiologist 2 attained 86.67%, 91.0%, and 88.5%, respectively. Our results suggest that ADC values could be a potential biomarker for use as a quantitative and qualitative tool for differentiating between early-stage endometrial carcinomas and benign mimickers.
Hu, Yumin; Zhou, Yongjin; Ye, Xinjian; Liu, Kun; Bai, Guanghui; Guo, Anna; Du, Meimei; Jiang, Lezhen
2017-01-01
Previous researchers obtained various apparent diffusion coefficient (ADC) cutoff values to differentiate endometrial carcinoma from benign mimickers with 1.5T magnetic resonance imaging (MRI). Few studies have used 3T MRI or validated the effectiveness of these cutoff ADC values prospectively. This study was designed in two stages to obtain a cutoff ADC value at 3T MRI and to validate prospectively the role of the ADC value. First, we conducted a retrospective study of 60 patients to evaluate the diagnostic value of ADC by obtain a theoretical cutoff ADC value for differentiating between benign and malignant endometrial lesions. Student's t test revealed that ADC values for stage I endometrial carcinomas were significantly lower than those for benign lesions. The area under the curve value of the receiver operating characteristic curve was 0.993, and the cutoff ADC value was 0.98 × 10−3 mm2/s. The sensitivity, specificity, and overall accuracy of diagnosing stage I endometrial carcinoma were 100%, 97.1%, and 98.3%, respectively. Second, we conducted a prospective study of 26 patients to validate the use of the cutoff ADC value obtained in the study's first stage. The sensitivity, specificity, and overall accuracy for differentiating malignant from benign endometrial lesions based on the cutoff ADC value obtained earlier were as follows: radiologist 1 attained 86.67%, 100.0%, and 92.31%, respectively; radiologist 2 attained 86.67%, 91.0%, and 88.5%, respectively. Our results suggest that ADC values could be a potential biomarker for use as a quantitative and qualitative tool for differentiating between early-stage endometrial carcinomas and benign mimickers. PMID:28634318
Putrescine biosynthesis in mammalian tissues.
Coleman, Catherine S; Hu, Guirong; Pegg, Anthony E
2004-01-01
L-ornithine decarboxylase provides de novo putrescine biosynthesis in mammals. Alternative pathways to generate putrescine that involve ADC (L-arginine decarboxylase) occur in non-mammalian organisms. It has been suggested that an ADC-mediated pathway may generate putrescine via agmatine in mammalian tissues. Published evidence for a mammalian ADC is based on (i) assays using mitochondrial extracts showing production of 14CO2 from [1-14C]arginine and (ii) cloned cDNA sequences that have been claimed to represent ADC. We have reinvestigated this evidence and were unable to find any evidence supporting a mammalian ADC. Mitochondrial extracts prepared from freshly isolated rodent liver and kidney using a metrizamide/Percoll density gradient were assayed for ADC activity using L-[U-14C]-arginine in the presence or absence of arginine metabolic pathway inhibitors. Although 14CO2 was produced in substantial amounts, no labelled agmatine or putrescine was detected. [14C]Agmatine added to liver extracts was not degraded significantly indicating that any agmatine derived from a putative ADC activity was not lost due to further metabolism. Extensive searches of current genome databases using non-mammalian ADC sequences did not identify a viable candidate ADC gene. One of the putative mammalian ADC sequences appears to be derived from bacteria and the other lacks several residues that are essential for decarboxylase activity. These results indicate that 14CO2 release from [1-14C]arginine is not adequate evidence for a mammalian ADC. Although agmatine is a known constituent of mammalian cells, it can be transported from the diet. Therefore L-ornithine decarboxylase remains the only established route for de novo putrescine biosynthesis in mammals. PMID:14763899
Karaman, Adem; Durur-Subasi, Irmak; Alper, Fatih; Durur-Karakaya, Afak; Subasi, Mahmut; Akgun, Metin
2017-10-01
To determine whether the use of necrosis/wall apparent diffusion coefficient (ADC) ratios in the differentiation of necrotic lung lesions is more reliable than measuring the wall alone. In this retrospective study, a total of 76 patients (54 males and 22 females, 71% vs. 29%, with a mean age of 53 ± 18 years, range, 18-84) were enrolled, 33 of whom had lung carcinoma and 43 had a benign necrotic lung lesion. A 3T scanner was used. The calculation of the necrosis/wall ADC ratio was based on ADC values measured from necrosis and the wall of the lesions by diffusion-weighted imaging (DWI). Statistical analyses were performed with the independent samples t-test and receiver operating characteristic analysis. Intraobserver and interobserver reliability were calculated for ADC values of wall and necrosis. The mean necrosis/wall ADC ratio was 1.67 ± 0.23 for malignant lesions and 0.75 ± 0.19 for benign lung lesions (P < 0.001). To estimate malignancy the area under the curve (AUC) values for necrosis ADC, wall ADC, and the necrosis/wall ADC ratio were 0.720, 0.073, and 0.997, respectively. A wall/necrosis ADC ratio cutoff value of 1.12 demonstrated a 100% sensitivity and 98% specificity in the estimation of malignancy. Positive predictive value was 100%, and negative predictive value 98% and diagnostic accuracy 99%. There was a good intraobserver and interobserver reliability for wall and necrosis. The necrosis/wall ADC ratio appears to be a reliable and promising tool for discriminating lung carcinoma from benign necrotic lung lesions than measuring the wall alone. 4 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2017;46:1001-1006. © 2017 International Society for Magnetic Resonance in Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shukla-Dave, A; Lu, Y; Hatzoglou, V
2014-06-15
Purpose: To investigate the repeatability of reduced field-of-view diffusion-weighted imaging (rFOV DWI) in quantifying apparent diffusion coefficients (ADCs) for human thyroid glands in a clinical setting. Methods: Nine healthy human volunteers were enrolled and underwent 3T MRI exams. For each volunteer, 3 longitudinal exams (2 weeks apart) with 2 repetitive sessions within each exam, including rFOV and conventional full field-of-view (fFOV) DWI scans, were performed. In the acquired DWI images, a fixed-size region of interest (ROI; diameter=8mm) was placed on thyroid glands to calculate ADC. ADC was calculated using a monoexponential function with a noise correction scheme. The repeatability ofmore » ADC was assessed by using coefficient variation (CV) across sessions or exams, which was defined to be: r = 1-CV, 0 < r < 1, where CV=STD/m, STD is the standard deviation of ADC, and m is the average of ADC across sessions or exams. An experienced radiologist assessed and scored rFOV and fFOV DW images based on image characteristics (1, nondiagnostic; 2, poor; 3, satisfactory; 4, good; and 5, excellent).Analysis of variance (ANOVA) was performed to compare ADC values, CV of ADC, repeatability of ADC across sessions and exams, and radiologic scores between rFOV and fFOV DWI techniques. Results: There was no significant difference in ADC values across sessions and exams either in rFOV or fFOV DWI. The average CVs of both rFOV and fFOV DWI were less than 13%. The repeatability of ADC measurement between rFOV and fFOV DWI was not significantly different. The overall image quality was significantly higher with rFOV DWI than with fFOV DWI. Conclusion: This study suggested that ADCs from both rFOV and fFOV DWI were repeatable, but rFOV DWI had superior imaging quality for human thyroid glands in a clinical setting.« less
Blackledge, Matthew D; Tunariu, Nina; Orton, Matthew R; Padhani, Anwar R; Collins, David J; Leach, Martin O; Koh, Dow-Mu
2016-01-01
Quantitative whole-body diffusion-weighted MRI (WB-DWI) is now possible using semi-automatic segmentation techniques. The method enables whole-body estimates of global Apparent Diffusion Coefficient (gADC) and total Diffusion Volume (tDV), both of which have demonstrated considerable utility for assessing treatment response in patients with bone metastases from primary prostate and breast cancers. Here we investigate the agreement (inter-observer repeatability) between two radiologists in their definition of Volumes Of Interest (VOIs) and subsequent assessment of tDV and gADC on an exploratory patient cohort of nine. Furthermore, each radiologist was asked to repeat his or her measurements on the same patient data sets one month later to identify the intra-observer repeatability of the technique. Using a Markov Chain Monte Carlo (MCMC) estimation method provided full posterior probabilities of repeatability measures along with maximum a-posteriori values and 95% confidence intervals. Our estimates of the inter-observer Intraclass Correlation Coefficient (ICCinter) for log-tDV and median gADC were 1.00 (0.97-1.00) and 0.99 (0.89-0.99) respectively, indicating excellent observer agreement for these metrics. Mean gADC values were found to have ICCinter = 0.97 (0.81-0.99) indicating a slight sensitivity to outliers in the derived distributions of gADC. Of the higher order gADC statistics, skewness was demonstrated to have good inter-user agreement with ICCinter = 0.99 (0.86-1.00), whereas gADC variance and kurtosis performed relatively poorly: 0.89 (0.39-0.97) and 0.96 (0.69-0.99) respectively. Estimates of intra-observer repeatability (ICCintra) demonstrated similar results: 0.99 (0.95-1.00) for log-tDV, 0.98 (0.89-0.99) and 0.97 (0.83-0.99) for median and mean gADC respectively, 0.64 (0.25-0.88) for gADC variance, 0.85 (0.57-0.95) for gADC skewness and 0.85 (0.57-0.95) for gADC kurtosis. Further investigation of two anomalous patient cases revealed that a very small proportion of voxels with outlying gADC values lead to instability in higher order gADC statistics. We therefore conclude that estimates of median/mean gADC and tumour volume demonstrate excellent inter- and intra-observer repeatability whilst higher order statistics of gADC should be used with caution when ascribing significance to clinical changes.
NASA Astrophysics Data System (ADS)
Perera, Dimuthu
Diffusion weighted (DW) Imaging is a non-invasive MR technique that provides information about the tissue microstructure using the diffusion of water molecules. The diffusion is generally characterized by the apparent diffusion coefficient (ADC) parametric map. The purpose of this study is to investigate in silico how the calculation of ADC is affected by image SNR, b-values, and the true tissue ADC. Also, to provide optimal parameter combination depending on the percentage accuracy and precision for prostate peripheral region cancer application. Moreover, to suggest parameter choices for any type of tissue, while providing the expected accuracy and precision. In this research DW images were generated assuming a mono-exponential signal model at two different b-values and for known true ADC values. Rician noise of different levels was added to the DWI images to adjust the image SNR. Using the two DWI images, ADC was calculated using a mono-exponential model for each set of b-values, SNR, and true ADC. 40,000 ADC data were collected for each parameter setting to determine the mean and the standard-deviation of the calculated ADC, as well as the percentage accuracy and precision with respect to the true ADC. The accuracy was calculated using the difference between known and calculated ADC. The precision was calculated using the standard-deviation of calculated ADC. The optimal parameters for a specific study was determined when both the percentage accuracy and precision were minimized. In our study, we simulated two true ADCs (ADC 0.00102 for tumor and 0.00180 mm2/s for normal prostate peripheral region tissue). Image SNR was varied from 2 to 100 and b-values were varied from 0 to 2000s/mm2. The results show that the percentage accuracy and percentage precision were minimized with image SNR. To increase SNR, 10 signal-averagings (NEX) were used considering the limitation in total scan time. The optimal NEX combination for tumor and normal tissue for prostate peripheral region was 1: 9. Also, the minimum percentage accuracy and percentage precision were obtained when low b-value is 0 and high b-value is 800 mm2/s for normal tissue and 1400 mm2/s for tumor tissue. Results also showed that for tissues with 1 x 10-3 < ADC < 2.1 x 10-3 mm 2/s the parameter combination at SNR = 20, b-value pair 0, 800 mm 2/s with NEX = 1:9 can calculate ADC with a percentage accuracy of less than 2% and percentage precision of 6-8%. Also, for tissues with 0.6 x 10-3 < ADC < 1.25 x 10-3 mm2 /s the parameter combination at SNR = 20, b-value pair 0, 1400 mm 2/s with NEX =1:9 can calculate ADC with a percentage accuracy of less than 2% and percentage precision of 6-8%.
Shutter heating system of Antarctic bright star survey telescope
NASA Astrophysics Data System (ADS)
Chen, Jie; Dong, Shucheng; Jiang, Fengxin; Zhang, Hongfei; Wang, Jian
2016-07-01
A heat preservation system for mechanical shutter in Antarctic is introduced in the paper. The system consists of the heat preservation chamber, the host controller STM32F103C8T6 with peripheral circuit and the control algorithm. The whole design is carried out on the basis of the low temperature requirement, including the cavity structure and thermal insulation. The heat preservation chamber is used to keep the shutter warm and support the weight of the camera. Using PT100 as the temperature sensor, the signal processing circuit converts the temperature to the voltage which is then digitized by the 12 bit ADC in the STM32. The host controller transforms the voltage data into temperature, and through the tuning of the Fussy PID algorithm which controls the duty cycle of the MOSFET, the temperature control of chamber is realized. The System has been tested in the cryogenic environment for a long time, with characteristic of low temperature resistance, small volume, high accuracy of temperature control as well as remote control and detection.
Low frequency noise elimination technique for 24-bit Σ-Δ data acquisition systems.
Qu, Shao-Bo; Robert, Olivier; Lognonné, Philippe; Zhou, Ze-Bing; Yang, Shan-Qing
2015-03-01
Low frequency 1/f noise is one of the key limiting factors of high precision measurement instruments. In this paper, digital correlated double sampling is implemented to reduce the offset and low frequency 1/f noise of a data acquisition system with 24-bit sigma delta (Σ-Δ) analog to digital converter (ADC). The input voltage is modulated by cross-coupled switches, which are synchronized to the sampling clock, and converted into digital signal by ADC. By using a proper switch frequency, the unwanted parasitic signal frequencies generated by the switches are avoided. The noise elimination processing is made through the principle of digital correlated double sampling, which is equivalent to a time shifted subtraction for the sampled voltage. The low frequency 1/f noise spectrum density of the data acquisition system is reduced to be flat down to the measurement frequency lower limit, which is about 0.0001 Hz in this paper. The noise spectrum density is eliminated by more than 60 dB at 0.0001 Hz, with a residual noise floor of (9 ± 2) nV/Hz(1/2) which is limited by the intrinsic white noise floor of the ADC above its corner frequency.
Towards a Standard Mixed-Signal Parallel Processing Architecture for Miniature and Microrobotics.
Sadler, Brian M; Hoyos, Sebastian
2014-01-01
The conventional analog-to-digital conversion (ADC) and digital signal processing (DSP) architecture has led to major advances in miniature and micro-systems technology over the past several decades. The outlook for these systems is significantly enhanced by advances in sensing, signal processing, communications and control, and the combination of these technologies enables autonomous robotics on the miniature to micro scales. In this article we look at trends in the combination of analog and digital (mixed-signal) processing, and consider a generalized sampling architecture. Employing a parallel analog basis expansion of the input signal, this scalable approach is adaptable and reconfigurable, and is suitable for a large variety of current and future applications in networking, perception, cognition, and control.
Towards a Standard Mixed-Signal Parallel Processing Architecture for Miniature and Microrobotics
Sadler, Brian M; Hoyos, Sebastian
2014-01-01
The conventional analog-to-digital conversion (ADC) and digital signal processing (DSP) architecture has led to major advances in miniature and micro-systems technology over the past several decades. The outlook for these systems is significantly enhanced by advances in sensing, signal processing, communications and control, and the combination of these technologies enables autonomous robotics on the miniature to micro scales. In this article we look at trends in the combination of analog and digital (mixed-signal) processing, and consider a generalized sampling architecture. Employing a parallel analog basis expansion of the input signal, this scalable approach is adaptable and reconfigurable, and is suitable for a large variety of current and future applications in networking, perception, cognition, and control. PMID:26601042
Cancer incidence in a Nationwide HIV/AIDS patient cohort in Taiwan in 1998-2009.
Chen, Marcelo; Jen, Ian; Chen, Yi-Hsien; Lin, Ming-Wei; Bhatia, Kishor; Sharp, Gerald B; Law, Matthew G; Arthur Chen, Yi-Ming
2014-04-01
The aims of this study were to investigate the cancer incidence and risk in HIV/AIDS patients relative to the general population in Taiwan. Using Taiwan's National Health Insurance Research Database, 15,269 HIV/AIDS patients were identified between 1998 and 2009. Gender-specific incidence densities (IDs) of both AIDS-defining cancers (ADC) and non-AIDS-defining cancers (NADC) after HIV infection were calculated. Age-, sex-, and period-adjusted standardized incidence rates (SIRs) were obtained using 1.8 million people from the general population as controls. A total of 1117 male and 165 female HIV/AIDS patients were diagnosed with cancer. Non-Hodgkin lymphoma (n = 196; ID = 328.79/100,000 person-years) and cervical cancer (n = 50; ID = 712.08/100,000 person-years) were the most common ADCs, whereas liver cancer (n = 125; ID = 184.52/100,000 person-years) and colon cancer (n = 11; ID = 156.66/100,000 person-years) were the most common NADCs in males and females, respectively. Period-adjusted gender-specific ADC and NADC rates decreased from more than 1500 cases/100,000 person-years to less than 500 cases/100,000 person-years (P < 0.001 for trend). SIRs of ADCs and NADCs also decreased. However, relative to the general population, increased SIRs were still seen for most cancers, many of which had an infectious etiology. The highest SIRs in ADCs and NADCs were seen in Kaposi sarcoma [SIR = 298.0, 95% confidence interval (CI): 258.16 to 343.85] and anal cancer (SIR = 19.10, 95% CI: 12.80 to 27.50). This study showed that although the cancer incidence rates have significantly decreased in the highly active antiretroviral therapy era, HIV/AIDS patients were still at increased risk of ADCs and most NADCs. Cancer screening, especially for infection-related NADCs, should therefore be promoted.
Milatuzumab-SN-38 conjugates for the treatment of CD74+ cancers.
Govindan, Serengulam V; Cardillo, Thomas M; Sharkey, Robert M; Tat, Fatma; Gold, David V; Goldenberg, David M
2013-06-01
CD74 is an attractive target for antibody-drug conjugates (ADC), because it internalizes and recycles after antibody binding. CD74 mostly is associated with hematologic tumors but is expressed also in solid cancers. Therefore, ADCs of the humanized anti-CD74 antibody, milatuzumab, were examined for the therapy of CD74-expressing solid tumors. Milatuzumab-doxorubicin and two milatuzumab-SN-38 conjugates with cleavable linkers, differing in their stability in serum and how they release SN-38 in the lysosome, were prepared. CD74 expression was determined by flow cytometry and immunohistology. In vitro cytotoxicity and in vivo therapeutic studies were conducted in the human cancer cell lines A-375 (melanoma), HuH-7 and Hep-G2 (hepatoma), Capan-1 (pancreatic), NCI-N87 (gastric), and Raji Burkitt lymphoma. The milatuzumab-SN-38 ADC was compared with SN-38 ADCs prepared with anti-Trop-2 and anti-CEACAM6 antibodies in xenografts expressing their target antigens. Milatuzumab-doxorubicin was most effective in the lymphoma model, whereas in A-375 and Capan-1 solid tumors, only milatuzumab-SN-38 showed a therapeutic benefit. Despite much lower surface expression of CD74 than Trop-2 or CEACAM6, milatuzumab-SN-38 had similar efficacy in Capan-1 as anti-Trop-2-SN-38, but in NCI-N87, anti-CEACAM6 and anti-Trop-2 conjugates were superior. Studies in two hepatoma lines at a single dose level showed significant benefit over saline controls but not against an irrelevant immunoglobulin G conjugate. CD74 is a suitable target for ADCs in some solid tumor xenografts, with efficacy largely influenced by uniformity of CD74 expression and with SN-38 conjugates providing the best therapeutic responses; SN-38 conjugates were preferable in solid cancers, whereas doxorubicin ADC was better in lymphoma tested. ©2013 AACR
Klerkx, Wenche M; Geldof, Albert A; Heintz, A Peter; van Diest, Paul J; Visser, Fredy; Mali, Willem P; Veldhuis, Wouter B
2011-05-01
To perform a longitudinal analysis of changes in lymph node volume and apparent diffusion coefficient (ADC) in healthy, metastatic, and hyperplastic lymph nodes. Three groups of four female Copenhagen rats were studied. Metastasis was induced by injecting cells with a high metastatic potential in their left hind footpad. Reactive nodes were induced by injecting Complete Freund Adjuvant (CFA). Imaging was performed at baseline and at 2, 5, 8, 11, and 14 days after tumor cell injection. Finally, lymph nodes were examined histopathologically. The model was highly efficient in inducing lymphadenopathy: subcutaneous cell or CFA inoculation resulted in ipsilateral metastatic or reactive popliteal lymph nodes in all rats. Metastatic nodal volumes increased exponentially from 5-7 mm(3) at baseline to 25 mm(3) at day 14, while the control node remained 5 mm(3). The hyperplastic nodes showed a rapid volume increase reaching a plateau at day 6. The ADC of metastatic nodes significantly decreased (range 13%-32%), but this decrease was also seen in reactive nodes. Metastatic and hyperplastic lymph nodes differed in terms of enlargement patterns and ADC changes. Enlarged reactive or malignant nodes could not be differentiated based on their ADC values. Copyright © 2011 Wiley-Liss, Inc.
ADC Histogram Analysis of Cervical Cancer Aids Detecting Lymphatic Metastases-a Preliminary Study.
Schob, Stefan; Meyer, Hans Jonas; Pazaitis, Nikolaos; Schramm, Dominik; Bremicker, Kristina; Exner, Marc; Höhn, Anne Kathrin; Garnov, Nikita; Surov, Alexey
2017-12-01
Apparent diffusion coefficient (ADC) histogram analysis has been used to some extent in cervical cancer (CC) to distinguish between low-grade and high-grade tumors. Although this differentiation is undoubtedly helpful, it would be even more crucial in the presurgical setting to determine whether a tumor already gained the potential to metastasize via the lymphatic system. So far, no studies investigated the potential of 3T ADC histogram analysis in CC to differentiate between nodal-positive and nodal-negative entities. Therefore, the principal aim of our study was to investigate the potential of 3T ADC histogram analysis to differentiate between CC with and without lymph node metastasis. The second aim was to elucidate possible differences in ADC histogram parameters between CC with limited vs. advanced tumor stages and well-differentiated vs. undifferentiated lesions. Finally, correlations of p53 expression and Ki-67 index with ADC parameters were analyzed. Eighteen female patients (mean age 55.4 years, range 32-79 years) with histopathologically confirmed cervical squamous cell carcinoma of the uterine cervix were prospectively enrolled. Tumor stages, tumor grading, status of metastatic dissemination, Ki67-index, and p53 expression were assessed in these patients. Diffusion weighted imaging (DWI) was obtained in a 3T scanner using the following b values: b0 and b1000 s/mm 2 . Group comparisons using Mann-Whitney U test revealed the following findings: nodal-positive CC had statistically significant lower ADC parameters (ADCmin, ADCmean, median ADC, Mode, p10, p25, p75, and p90) in comparison to nodal-negative CC (all p < 0.05). ADCentropy was significantly elevated (p = 0.046) in tumors with advanced T stages (T3/4) compared to tumors with limited T stage (T2). ADCmin values were different in a statistically significant manner comparing G1/G2 and G3 tumors (40.45 ± 18.63 vs. 65.0 ± 23.63 × 10-5 mm2 s -1 , p = 0.035). Furthermore, Spearman Rho calculation identified an inverse correlation between ADCentropy and p53 expression (r = -0.472, p = 0.048). The main finding of our study is the discriminability of nodal-positive from nodal-negative CC using ADC histogram analysis in 3T DWI. This information is crucial for the gynecological surgeon to identify the optimal treatment strategy for patients suffering from CC. Furthermore, ADCentropy was identified as a potential imaging biomarker for tumor heterogeneity and might be able to indicate further molecular changes like loss of p53 expression, which is associated with EMT and consequentially indicates a poor prognosis in CC. Finally, our study confirmed the findings of previous works, which indicated that histogram analysis of ADC maps can distinguish between low-grade and high-grade CC. In conclusion, it can be stated that ADC histogram analysis provides additional, prognostically important information on tumor biology in CC.
NASA Astrophysics Data System (ADS)
Lee, Dae Young
The design of a small satellite is challenging since they are constrained by mass, volume, and power. To mitigate these constraint effects, designers adopt deployable configurations on the spacecraft that result in an interesting and difficult optimization problem. The resulting optimization problem is challenging due to the computational complexity caused by the large number of design variables and the model complexity created by the deployables. Adding to these complexities, there is a lack of integration of the design optimization systems into operational optimization, and the utility maximization of spacecraft in orbit. The developed methodology enables satellite Multidisciplinary Design Optimization (MDO) that is extendable to on-orbit operation. Optimization of on-orbit operations is possible with MDO since the model predictive controller developed in this dissertation guarantees the achievement of the on-ground design behavior in orbit. To enable the design optimization of highly constrained and complex-shaped space systems, the spherical coordinate analysis technique, called the "Attitude Sphere", is extended and merged with an additional engineering tools like OpenGL. OpenGL's graphic acceleration facilitates the accurate estimation of the shadow-degraded photovoltaic cell area. This technique is applied to the design optimization of the satellite Electric Power System (EPS) and the design result shows that the amount of photovoltaic power generation can be increased more than 9%. Based on this initial methodology, the goal of this effort is extended from Single Discipline Optimization to Multidisciplinary Optimization, which includes the design and also operation of the EPS, Attitude Determination and Control System (ADCS), and communication system. The geometry optimization satisfies the conditions of the ground development phase; however, the operation optimization may not be as successful as expected in orbit due to disturbances. To address this issue, for the ADCS operations, controllers based on Model Predictive Control that are effective for constraint handling were developed and implemented. All the suggested design and operation methodologies are applied to a mission "CADRE", which is space weather mission scheduled for operation in 2016. This application demonstrates the usefulness and capability of the methodology to enhance CADRE's capabilities, and its ability to be applied to a variety of missions.
Horvath-Rizea, Diana; Surov, Alexey; Hoffmann, Karl-Titus; Garnov, Nikita; Vörkel, Cathrin; Kohlhof-Meinecke, Patricia; Ganslandt, Oliver; Bäzner, Hansjörg; Gihr, Georg Alexander; Kalman, Marcell; Henkes, Elina; Henkes, Hans; Schob, Stefan
2018-04-06
Morphologically similar appearing ring enhancing lesions in the brain parenchyma can be caused by a number of distinct pathologies, however, they consistently represent life-threatening conditions. The two most frequently encountered diseases manifesting as such are glioblastoma multiforme (GBM) and brain abscess (BA), each requiring disparate therapeutical approaches. As a result of their morphological resemblance, essential treatment might be significantly delayed or even ommited, in case results of conventional imaging remain inconclusive. Therefore, our study aimed to investigate, whether ADC histogram profiling reliably can distinguish between both entities, thus enhancing the differential diagnostic process and preventing treatment failure in this highly critical context. 103 patients (51 BA, 52 GBM) with histopathologically confirmed diagnosis were enrolled. Pretreatment diffusion weighted imaging (DWI) was obtained in a 1.5T system using b values of 0, 500, and 1000 s/mm 2 . Whole lesion ADC volumes were analyzed using a histogram-based approach. Statistical analysis was performed using SPSS version 23. All investigated parameters were statistically different in comparison of both groups. Most importantly, ADCp10 was able to differentiate reliably between BA and GBM with excellent accuracy (0.948) using a cutpoint value of 70 × 10 -5 mm 2 × s -1 . ADC whole lesion histogram profiling provides a valuable tool to differentiate between morphologically indistinguishable mass lesions. Among the investigated parameters, the 10th percentile of the ADC volume distinguished best between GBM and BA.
Effects of a direct refill program for automated dispensing cabinets on medication-refill errors.
Helmons, Pieter J; Dalton, Ashley J; Daniels, Charles E
2012-10-01
The effects of a direct refill program for automated dispensing cabinets (ADCs) on medication-refill errors were studied. This study was conducted in designated acute care areas of a 386-bed academic medical center. A wholesaler-to-ADC direct refill program, consisting of prepackaged delivery of medications and bar-code-assisted ADC refilling, was implemented in the inpatient pharmacy of the medical center in September 2009. Medication-refill errors in 26 ADCs from the general medicine units, the infant special care unit, the surgical and burn intensive care units, and intermediate units were assessed before and after the implementation of this program. Medication-refill errors were defined as an ADC pocket containing the wrong drug, wrong strength, or wrong dosage form. ADC refill errors decreased by 77%, from 62 errors per 6829 refilled pockets (0.91%) to 8 errors per 3855 refilled pockets (0.21%) (p < 0.0001). The predominant error type detected before the intervention was the incorrect medication (wrong drug, wrong strength, or wrong dosage form) in the ADC pocket. Of the 54 incorrect medications found before the intervention, 38 (70%) were loaded in a multiple-drug drawer. After the implementation of the new refill process, 3 of the 5 incorrect medications were loaded in a multiple-drug drawer. There were 3 instances of expired medications before and only 1 expired medication after implementation of the program. A redesign of the ADC refill process using a wholesaler-to-ADC direct refill program that included delivery of prepackaged medication and bar-code-assisted refill significantly decreased the occurrence of ADC refill errors.
Investigational Antibody-Drug Conjugates for Treatment of B-lineage Malignancies.
Herrera, Alex F; Molina, Arturo
2018-05-10
Antibody-drug conjugates (ADCs) are tripartite molecules consisting of a monoclonal antibody, a covalent linker, and a cytotoxic payload. ADC development has aimed to target the specificity inherent in antigen-antibody interactions to deliver potent cytotoxins preferentially to tumor cells and maximize antitumor activity and simultaneously minimize off-target toxicity. The earliest ADCs provided disappointing results in the clinic; however, the lessons learned regarding the need for human or humanized antibodies, more stable linkers, and greater potency payloads led to improved ADCs. Three ADCs, gemtuzumab ozogamicin, brentuximab vedotin (BV), and inotuzumab ozogamicin, have been approved for hematologic malignancies. Site-specific conjugation methods have now resulted in a new generation of more uniform, molecularly defined ADCs. These are expected to display improved in vivo properties and have recently entered the clinic. We reviewed investigational ADCs currently in clinical testing for the treatment of B-cell lineage malignancies, including leukemias, lymphomas, and multiple myeloma. The rationales for antigen targeting, data reported to date, current trial status, and preclinical results for several newer ADCs expected to enter first-in-human studies are presented. Owing to the large number of ongoing and reported BV clinical studies, only the studies of BV for diffuse large B-cell lymphoma and those combining BV with checkpoint inhibitors in B-lineage malignancies have been reviewed. With > 40 ongoing clinical trials and 7 investigational ADCs already having advanced to phase II studies, the role of ADCs in the armamentarium for the treatment of B-lineage malignancies continues to be elucidated. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.
Bråtane, Bernt Tore; Bastan, Birgul; Fisher, Marc; Bouley, James; Henninger, Nils
2009-07-07
Though diffusion weighted imaging (DWI) is frequently used for identifying the ischemic lesion in focal cerebral ischemia, the understanding of spatiotemporal evolution patterns observed with different analysis methods remains imprecise. DWI and calculated apparent diffusion coefficient (ADC) maps were serially obtained in rat stroke models (MCAO): permanent, 90 min, and 180 min temporary MCAO. Lesion volumes were analyzed in a blinded and randomized manner by 2 investigators using (i) a previously validated ADC threshold, (ii) visual determination of hypointense regions on ADC maps, and (iii) visual determination of hyperintense regions on DWI. Lesion volumes were correlated with 24 hour 2,3,5-triphenyltetrazoliumchloride (TTC)-derived infarct volumes. TTC-derived infarct volumes were not significantly different from the ADC and DWI-derived lesion volumes at the last imaging time points except for significantly smaller DWI lesions in the pMCAO model (p=0.02). Volumetric calculation based on TTC-derived infarct also correlated significantly stronger to volumetric calculation based on last imaging time point derived lesions on ADC maps than DWI (p<0.05). Following reperfusion, lesion volumes on the ADC maps significantly reduced but no change was observed on DWI. Visually determined lesion volumes on ADC maps and DWI by both investigators correlated significantly with threshold-derived lesion volumes on ADC maps with the former method demonstrating a stronger correlation. There was also a better interrater agreement for ADC map analysis than for DWI analysis. Ischemic lesion determination by ADC was more accurate in final infarct prediction, rater independent, and provided exclusive information on ischemic lesion reversibility.
Lober, Robert M; Cho, Yoon-Jae; Tang, Yujie; Barnes, Patrick D; Edwards, Michael S; Vogel, Hannes; Fisher, Paul G; Monje, Michelle; Yeom, Kristen W
2014-03-01
While pediatric diffuse intrinsic pontine gliomas (DIPG) remain fatal, recent data have shown subgroups with distinct molecular biology and clinical behavior. We hypothesized that diffusion-weighted MRI can be used as a prognostic marker to stratify DIPG subsets with distinct clinical behavior. Apparent diffusion coefficient (ADC) values derived from diffusion-weighted MRI were computed in 20 consecutive children with treatment-naïve DIPG tumors. The median ADC for the cohort was used to stratify the tumors into low and high ADC groups. Survival, gender, therapy, and potential steroid effects were compared between the ADC groups. Median age at diagnosis was 6.6 (range 2.3-13.2) years, with median follow-up seven (range 1-36) months. There were 14 boys and six girls. Seventeen patients received radiotherapy, five received chemotherapy, and six underwent cerebrospinal fluid diversion. The median ADC of 1,295 × 10(-6) mm(2)/s for the cohort partitioned tumors into low or high diffusion groups, which had distinct median survivals of 3 and 13 months, respectively (log-rank p < 0.001). Low ADC tumors were found only in boys, whereas high ADC tumors were found in both boys and girls. Available tissue specimens in three low ADC tumors demonstrated high-grade histology, whereas one high ADC tumor demonstrated low-grade histology with a histone H3.1 K27M mutation and high-grade metastatic lesion at autopsy. ADC derived from diffusion-weighted MRI may identify prognostically distinct subgroups of pediatric DIPG.
Lipid peroxidation and antioxidant status in colorectal cancer
Skrzydlewska, Elzbieta; Sulkowski, Stanislaw; Koda, Mariusz; Zalewski, Bogdan; Kanczuga-Koda, Luiza; Sulkowska, Mariola
2005-01-01
AIM: Reactive oxygen species (ROS) can induce carcinogenesis via DNA injury. Both enzymatic and non-enzymatic parameters participate in cell protection against harmful influence of oxidative stress. The aim of the present study was to assess the levels of final lipid peroxidation products like malondialdehyde (MDA) and 4-hydroxy-2-nonenal (4-HNE) in primary colorectal cancer. Moreover, we analysed the activity of main antioxidative enzymes, superoxide dismutase (Cu, Zn-SOD), catalase (CAT), glutathione peroxidase (GSH-Px) and glutathione reductase (GSSRG-R) and the level of non-enzymatic antioxidants (glutathione, vitamins C and E). METHODS: Investigations were conducted in 81 primary colorectal cancers. As a control, the same amount of sample was collected from macroscopically unchanged colon regions of the most distant location to the cancer. Homogenisation of specimens provided 10% homogenates for our evaluations. Activity of antioxidant enzymes and level of glutathione were determined by spectrophotometry. HPLC revealed levels of vitamins C and E and served as a method to detect terminal products of lipid peroxidation in colorectal cancer. RESULTS: Our studies demonstrated a statistically significant increase in the level of lipid peroxidation products (MDA-Adc.muc.-2.65±0.48 nmol/g, Adc.G3-2.15±0.44 nmol/g, clinical IV stage 4.04±0.47 nmol/g, P<0.001 and 4-HNE-Adc.muc. -0.44±0.07 nmol/g, Adc.G3-0.44±0.10 nmol/g, clinical IV stage 0.52±0.11 nmol/g, P<0.001) as well as increase of Cu,Zn-SOD (Adc.muc.-363±72 U/g, Adc.G3-318±48 U/g, clinical IV stage 421±58 U/g, P<0.001), GSH-Px (Adc.muc. -2143±623 U/g, Adc.G3-2005±591 U/g, clinical IV stage 2467±368 U/g, P<0.001) and GSSG-R (Adc.muc.-880±194 U/g, Adc.G3-795±228 U/g, clinical IV stage 951±243 U/g, P<0.001) in primary tumour comparison with normal colon (MDA-1.39±0.15 nmol/g, HNE-0.29±0.03 nmol/g, Cu, Zn-SOD-117±25 U/g, GSH-Px-1723±189 U/g, GSSG-R-625±112 U/g) especially in mucinous and G3-grade adenocarcinomas as well as clinical IV stage of colorectal cancer. We also observed a decrease of CAT activity (Adc.muc. -40±14 U/g, clinical IV stage 33±18 U/g vs 84±17 U/g, P<0.001) as well as a decreased level of reduced glutathione (clinical IV stage 150±48 nmol/g vs 167±15 nmol/g, P<0.05) and vitamins C and E (vit. C-clinical IV stage 325±92 nmol/g vs 513±64 nmol/g, P<0.001; vit. E-clinical IV stage 13.3±10.3 nmol/g vs 37.5±5.2 nmol/g). CONCLUSION: Colorectal carcinogenesis is associated with serious oxidative stress and confirms that gradual advancement of oxidative-antioxidative disorders is followed by progression of colorectal cancer. PMID:15637754
High performance photonic ADC for space applications
NASA Astrophysics Data System (ADS)
Pantoja, S.; Piqueras, M. A.; Villalba, P.; Martínez, B.; Rico, E.
2017-11-01
The flexibility required for future telecom payloads will require of more digital processing capabilities, moving from conventional analogue repeaters to more advanced and efficient analog subsystems or DSPbased solutions. Aggregate data throughputs will have to be handled onboard, creating the need for effective, ADC/DSP and DSP/DAC high speed links. Broadband payloads will have to receive, route and retransmit hundreds of channels and need to be designed so as to meet such requirements of larger bandwidth, system transparency and flexibility.[1][2] One important device in these new architectures is analog to digital converter (ADC) and its equivalent digital to analog converter (DAC). These will be the in/out interface for the use of digital processing in order to provide flexible beam to beam connectivity and variable bandwidth allocation. For telecom payloads having a large number of feeds and thus a large number of converters the mass and consumption of the mixer stage has become significant. Moreover, the inclusion of ADCs in the payload presents new trade-offs in design (jitter, quantization noise, ambiguity). This paper deals with an alternative solution of these two main problems with the exploitation of photonic techniques.
Domínguez-Pinilla, N; Martínez de Aragón, A; Diéguez Tapias, S; Toldos, O; Hinojosa Bernal, J; Rigal Andrés, M; González-Granado, L I
2016-09-01
The apparent diffusion coefficient (ADC) in MRI seems to be related to cellularity in brain tumours. Its utility as a tool for distinguishing between histological types and tumour stages remains controversial. We retrospectively evaluated children diagnosed with CNS tumours between January 2008 and December 2013. Data collected were age, sex, histological diagnosis, and location of the tumour. We evaluated the ADC and ADC ratio and correlated those values with histological diagnoses. The study included 55 patients with a median age of 6 years. Histological diagnoses were pilocytic astrocytoma (40%), anaplastic ependymoma (16.4%), ganglioglioma (10.9%), glioblastoma (7.3%), medulloblastoma (5.5%), and other (20%). Tumours could also be classified as low-grade (64%) or high-grade (36%). Mean ADC was 1.3 for low-grade tumours and 0.9 for high-grade tumours (p=.004). Mean ADC ratios were 1.5 and 1.2 for low and high-grade tumours respectively (p=.025). There were no significant differences in ADC/ADC ratio between different histological types. ADC and ADC ratio may be useful in imaging-study based differential diagnosis of low and high-grade tumours, but they are not a substitute for an anatomical pathology study. Copyright © 2014 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.
Bonekamp, David; Bonekamp, Susanne; Ou, Hsin-You; Torbenson, Michael S; Corona-Villalobos, Celia Pamela; Mezey, Esteban; Kamel, Ihab R
2014-11-01
Noninvasive markers have been developed to reduce the need for liver biopsy. The aim of this study was to compare the strength of association of the arterial enhancement fraction (AEF), apparent diffusion coefficient (ADC), and serum biomarkers for staging hepatic fibrosis. Eighty-five patients with chronic liver disease underwent triple-phase contrast-enhanced MRI, used to calculate AEF, and diffusion-weighted MRI (b = 0,750 s/mm(2) ), used to calculate ADC. Hepatic fibrosis was staged according METAVIR criteria. The overall association of the four biomarkers (AEF, ADC, aspartate aminotransferase (AST)/alanine aminotransferase (ALT) ratio, and aspartate aminotransferase to platelet ratio index [APRI]) was compared using nonparametric tests and receiver operating characteristic (ROC) curve, using histopathologic analysis as the reference standard. AEF and ADC values differed significantly between histopathologic fibrosis stages. AEF values correlated with fibrosis stage, ADC values correlated negatively with fibrosis stage. Compared with ADC, AEF showed a trend toward an improved capability of discriminating fibrosis stages. A weighted composite score of AEF and ADC had significantly better diagnostic accuracy than ADC alone (P ≤ 0.023). Imaging parameters had a significantly better diagnostic accuracy than AST/ALT ratio or APRI. AEF may be able to detect the presence of mild, moderate, and advanced liver fibrosis, and its value is increased with concomitant use of ADC. © 2013 Wiley Periodicals, Inc.
Time lens assisted photonic sampling extraction
NASA Astrophysics Data System (ADS)
Petrillo, Keith Gordon
Telecommunication bandwidth demands have dramatically increased in recent years due to Internet based services like cloud computing and storage, large file sharing, and video streaming. Additionally, sensing systems such as wideband radar, magnetic imaging resonance systems, and complex modulation formats to handle large data transfer in telecommunications require high speed, high resolution analog-to-digital converters (ADCs) to interpret the data. Accurately processing and acquiring the information at next generation data rates from these systems has become challenging for electronic systems. The largest contributors to the electronic bottleneck are bandwidth and timing jitter which limit speed and reduce accuracy. Optical systems have shown to have at least three orders of magnitude increase in bandwidth capabilities and state of the art mode locked lasers have reduced timing jitters into thousands of attoseconds. Such features have encouraged processing signals without the use of electronics or using photonics to assist electronics. All optical signal processing has allowed the processing of telecommunication line rates up to 1.28 Tb/s and high resolution analog-to-digital converters in the 10s of gigahertz. The major drawback to these optical systems is the high cost of the components. The application of all optical processing techniques such as a time lens and chirped processing can greatly reduce bandwidth and cost requirements of optical serial to parallel converters and push photonically assisted ADCs into the 100s of gigahertz. In this dissertation, the building blocks to a high speed photonically assisted ADC are demonstrated, each providing benefits to its own respective application. A serial to parallel converter using a continuously operating time lens as an optical Fourier processor is demonstrated to fully convert a 160-Gb/s optical time division multiplexed signal to 16 10-Gb/s channels with error free operation. Using chirped processing, an optical sample and hold concept is demonstrated and analyzed as a resolution improvement to existing photonically assisted ADCs. Simulations indicate that the application of a continuously operating time lens to a photonically assisted sampling system can increase photonically sampled systems by an order of magnitude while acquiring properties similar to an optical sample and hold system.
High speed analog-to-digital conversion with silicon photonics
NASA Astrophysics Data System (ADS)
Holzwarth, C. W.; Amatya, R.; Araghchini, M.; Birge, J.; Byun, H.; Chen, J.; Dahlem, M.; DiLello, N. A.; Gan, F.; Hoyt, J. L.; Ippen, E. P.; Kärtner, F. X.; Khilo, A.; Kim, J.; Kim, M.; Motamedi, A.; Orcutt, J. S.; Park, M.; Perrott, M.; Popovic, M. A.; Ram, R. J.; Smith, H. I.; Zhou, G. R.; Spector, S. J.; Lyszczarz, T. M.; Geis, M. W.; Lennon, D. M.; Yoon, J. U.; Grein, M. E.; Schulein, R. T.; Frolov, S.; Hanjani, A.; Shmulovich, J.
2009-02-01
Sampling rates of high-performance electronic analog-to-digital converters (ADC) are fundamentally limited by the timing jitter of the electronic clock. This limit is overcome in photonic ADC's by taking advantage of the ultra-low timing jitter of femtosecond lasers. We have developed designs and strategies for a photonic ADC that is capable of 40 GSa/s at a resolution of 8 bits. This system requires a femtosecond laser with a repetition rate of 2 GHz and timing jitter less than 20 fs. In addition to a femtosecond laser this system calls for the integration of a number of photonic components including: a broadband modulator, optical filter banks, and photodetectors. Using silicon-on-insulator (SOI) as the platform we have fabricated these individual components. The silicon optical modulator is based on a Mach-Zehnder interferometer architecture and achieves a VπL of 2 Vcm. The filter banks comprise 40 second-order microring-resonator filters with a channel spacing of 80 GHz. For the photodetectors we are exploring ion-bombarded silicon waveguide detectors and germanium films epitaxially grown on silicon utilizing a process that minimizes the defect density.
Effects of Diffusion Time on Short-Range Hyperpolarized 3He Diffusivity Measurements in Emphysema
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gierada, David S.; Woods, Jason C.; Bierhals, Andrew J.
2009-09-28
Purpose: To characterize the effect of diffusion time on short-range hyperpolarized 3He MR diffusion measurements across a wide range of emphysema severity. Materials and Methods: 3He diffusion MR imaging was performed on 19 lungs or lobes resected from 18 subjects with varying degrees of emphysema using 3 diffusion times (1.6 msec, 5 msec, and 10 msec) at constant b value. Emphysema severity was quantified as the mean apparent diffusion coefficient (ADC) and as the percentage of pixels with ADC higher than multiple thresholds from 0.30-0.55 cm2/sec (ADC index). Quantitative histology (mean linear intercept) was obtained in 10 of the lungmore » specimens from 10 of the subjects. Results: The mean ADCs with diffusion times of 1.6, 5.0, and 10.0 msec were 0.46, 0.40, and 0.37 cm2/sec, respectively (P <0.0001, ANOVA). There was no relationship between the ADC magnitude and the effect of diffusion time on ADC values. Mean linear intercept correlated with ADC (r=0.91-0.94, P<0.001) and ADC index (r=0.78-0.92, P<0.01) at all diffusion times.« less
Vermoolen, M A; Kwee, T C; Nievelstein, R A J
2012-08-01
To systematically review the value of apparent diffusion coefficient (ADC) measurement in the differentiation between benign and malignant lesions. A systematic search of the Medline/Pubmed and Embase databases revealed 109 relevant studies. Quality of these articles was assessed using the Quality Assessment of the Studies of Diagnostic Accuracy Included in Systematic Reviews (QUADAS) criteria. Reported ADC values of benign and malignant lesions were compared per organ. The mean quality score of the reviewed articles was 50%. Comparison of ADC values showed marked variation among studies and between benign and malignant lesions in various organs. In several organs, such as breast, liver, and uterus, ADC values discriminated well between benign and malignant lesions. In other organs, such as the salivary glands, thyroid, and pancreas, ADCs were not significantly different between benign and malignant lesions. The potential utility of ADC measurement for the characterisation of tumours differs per organ. Future well-designed studies are required before ADC measurements can be recommended for the differentiation of benign and malignant lesions. These future studies should use standardised acquisition protocols and provide complete reporting of study methods, to facilitate comparison of results and clinical implementation of ADC measurement for tumour characterisation.
Cao, Kun; Li, Nan; Wang, Hongcui; Cao, Xin; He, Jiaojiao; Zhang, Bing; He, Qing-Yu; Zhang, Gong; Sun, Xuesong
2018-04-20
Zinc is an essential metal in bacteria. One important bacterial zinc transporter is AdcA, and most bacteria possess AdcA homologs that are single-domain small proteins due to better efficiency of protein biogenesis. However, a double-domain AdcA with two zinc-binding sites is significantly overrepresented in Streptococcus species, many of which are major human pathogens. Using molecular simulation and experimental validations of AdcA from Streptococcus pyogenes , we found here that the two AdcA domains sequentially stabilize the structure upon zinc binding, indicating an organization required for both increased zinc affinity and transfer speed. This structural organization appears to endow Streptococcus species with distinct advantages in zinc-depleted environments, which would not be achieved by each single AdcA domain alone. This enhanced zinc transport mechanism sheds light on the significance of the evolution of the AdcA domain fusion, provides new insights into double-domain transporter proteins with two binding sites for the same ion, and indicates a potential target of antimicrobial drugs against pathogenic Streptococcus species. © 2018 by The American Society for Biochemistry and Molecular Biology, Inc.
Guan, Yue; Shi, Hua; Chen, Ying; Liu, Song; Li, Weifeng; Jiang, Zhuoran; Wang, Huanhuan; He, Jian; Zhou, Zhengyang; Ge, Yun
2016-01-01
The aim of this study was to explore the application of whole-lesion histogram analysis of apparent diffusion coefficient (ADC) values of cervical cancer. A total of 54 women (mean age, 53 years) with cervical cancers underwent 3-T diffusion-weighted imaging with b values of 0 and 800 s/mm prospectively. Whole-lesion histogram analysis of ADC values was performed. Paired sample t test was used to compare differences in ADC histogram parameters between cervical cancers and normal cervical tissues. Receiver operating characteristic curves were constructed to identify the optimal threshold of each parameter. All histogram parameters in this study including ADCmean, ADCmin, ADC10%-ADC90%, mode, skewness, and kurtosis of cervical cancers were significantly lower than those of normal cervical tissues (all P < 0.0001). ADC90% had the largest area under receiver operating characteristic curve of 0.996. Whole-lesion histogram analysis of ADC maps is useful in the assessment of cervical cancer.
An Analysis of Offset, Gain, and Phase Corrections in Analog to Digital Converters
NASA Astrophysics Data System (ADS)
Cody, Devin; Ford, John
2015-01-01
Many high-speed analog to digital converters (ADCs) use interwoven ADCs to greatly boost their sample rate. This interwoven architecture can introduce problems if the low speed ADCs do not have identical outputs. These errors are manifested as phantom frequencies that appear in the digitized signal although they never existed in the analog domain. Through the application of offset, gain, and phase (OGP) corrections to the ADC, this problem can be reduced. Here we report on an implementation of such a correction in a high speed ADC chip used for radio astronomy. While the corrections could not be implemented in the ADCs themselves, a partial solution was devised and implemented digitally inside of a signal processing field programmable gate array (FPGA). Positive results to contrived situations are shown, and null results are presented for implementation in an ADC083000 card with minimal error. Lastly, we discuss the implications of this method as well as its mathematical basis.
Lemaire, L; Howe, F A; Rodrigues, L M; Griffiths, J R
1999-03-01
Chemosensitivity of N-methyl-N-nitrosourea-induced rat mammary tumours treated with 5-fluorouracil at a dose of 100 mg kg(-1) i.p. was assessed by using diffusion-weighted 1H-MRS to measure the average diffusion coefficient (ADC) of water in the tumour tissue. ADC measurements prior to any therapy correlated positively with necrotic fraction. Tumours with low initial ADC (< 0.95 x 10(9) m2 s(-1)) showed an increase in ADC 7 days after treatment, whereas tumours with a high initial ADC (> 1.2 x 10(9) m2 s(-1)) showed a decrease. All tumours decreased significantly in volume (P < 0.05) 2, 5 and 7 days after treatment. At day 7 post-treatment, tumours with a high pre-treatment ADC started to regrow. The initial ADC value, as well as changes after treatment predict tumour chemosensitivity, which could be clinically relevant.
Astronomical catalog desk reference, 1994 edition
NASA Technical Reports Server (NTRS)
1994-01-01
The Astronomical Catalog Desk Reference is designed to aid astronomers in locating machine readable catalogs in the Astronomical Data Center (ADC) archives. The key reference components of this document are as follows: A listing of shortened titles for all catalogs available from the ADC (includes the name of the lead author and year of publication), brief descriptions of over 300 astronomical catalogs, an index of ADC catalog numbers by subject keyword, and an index of ADC catalog numbers by author. The heart of this document is the set of brief descriptions generated by the ADC staff. The 1994 edition of the Astronomical Catalog Desk Reference contains descriptions for over one third of the catalogs in the ADC archives. Readers are encouraged to refer to this section for concise summaries of those catalogs and their contents.
Giannotti, E; Waugh, S; Priba, L; Davis, Z; Crowe, E; Vinnicombe, S
2015-09-01
Apparent Diffusion Coefficient (ADC) measurements are increasingly used for assessing breast cancer response to neoadjuvant chemotherapy although little data exists on ADC measurement reproducibility. The purpose of this work was to investigate and characterise the magnitude of errors in ADC measures that may be encountered in such follow-up studies- namely scanner stability, scan-scan reproducibility, inter- and intra- observer measures and the most reproducible measurement of ADC. Institutional Review Board approval was obtained for the prospective study of healthy volunteers and written consent acquired for the retrospective study of patient images. All scanning was performed on a 3.0-T MRI scanner. Scanner stability was assessed using an ice-water phantom weekly for 12 weeks. Inter-scan repeatability was assessed across two scans of 10 healthy volunteers (26-61 years; mean: 44.7 years). Inter- and intra-reader analysis repeatability was measured in 52 carcinomas from clinical patients (29-70 years; mean: 50.0 years) by measuring the whole tumor ADC value on a single slice with maximum tumor diameter (ADCS) and the ADC value of a small region of interest (ROI) on the same slice (ADCmin). Repeatability was assessed using intraclass correlation coefficients (ICC) and coefficients of repeatability (CoR). Scanner stability contributed 6% error to phantom ADC measurements (0.071×10(-3)mm(2)/s; mean ADC=1.089×10(-3)mm(2)/s). The measured scan-scan CoR in the volunteers was 0.122×10(-3)mm(2)/s, contributing an error of 8% to the mean measured values (ADCscan1=1.529×10(-3)mm(2)/s; ADCscan2=1.507×10(-3)mm(2)/s). Technical and clinical observers demonstrated excellent intra-observer repeatability (ICC>0.9). Clinical observer CoR values were marginally better than technical observer measures (ADCS=0.035×10(-3)mm(2)/s vs. 0.097×10(-3)mm(2)/s; ADCmin=0.09×10(-3)mm(2)/s vs. 0.114×10(-3)mm(2)/s). Inter-reader ICC values were good 0.864 (ADCS) and fair 0.677 (ADCmin). Corresponding CoR values were 0.202×10(-3)mm(2)/s and 0.264×10(-3)mm(2)/s, respectively. Both scanner stability and scan-scan variation have minimal influence on breast ADC measurements, contributing less than 10% error of average measured ADC values. Measurement of ADC values from a small ROI contributes a greater variability in measurements compared with measurement of ADC across the whole visible tumor on one slice. The greatest source of error in follow-up studies is likely to be associated with measures made by multiple observers, and this should be considered where multiple measures are required to assess response to treatment. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
uSOP: A Microprocessor-Based Service-Oriented Platform for Control and Monitoring
NASA Astrophysics Data System (ADS)
Aloisio, Alberto; Ameli, Fabrizio; Anastasio, Antonio; Branchini, Paolo; Di Capua, Francesco; Giordano, Raffaele; Izzo, Vincenzo; Tortone, Gennaro
2017-06-01
uSOP is a general purpose single-board computer designed for deep embedded applications in control and monitoring of detectors, sensors, and complex laboratory equipment. In this paper, we present and discuss the main aspects of the hardware and software designs and the expandable peripheral architecture built around serial busses. We show the tests done with state-of-the-art ΔΣ 24-b ADC acquisition modules, in order to assess the achievable noise floor in a typical application. Eventually, we report on the deployment of uSOP in the monitoring system framework of the Belle2 experiment, presently under construction at the KEK Laboratory (Tsukuba, Japan).
Tan, Yan; Zhang, Hui; Wang, Xiao-Chun; Qin, Jiang-Bo; Wang, Le
2018-06-01
To investigate the value of multi-ultrahigh-b-value diffusion-weighted imaging (UHBV-DWI) in differentiating high-grade astrocytomas (HGAs) from low-grade astrocytomas (LGAs), analyze its association with aquaporin (AQP) expression. 40 astrocytomas divided into LGAs (N = 15) and HGAs (N = 25) were studied. Apparent diffusion coefficient (ADC) and UHBV-ADC values in solid parts and peritumoral edema were compared between LGAs and HGAs groups by the t-test. Using receiver operating characteristic curves to identify the better parameter. Using real time polymerase chain reaction to assess AQP messenger ribonucleic acid (mRNA). Using spearman correlation analysis to assess the correlation of AQP mRNA with each parameter. ADC values in solid parts of HGAs were significantly lower than LGAs (p = 0.02), while UHBV-ADC values of HGAs were significantly higher than LGAs (p < 0.01). Area under the curve (AUC) of UHBV-ADC (0.810) was larger than ADC (0.713), and the area under the curve of UHBV-ADC was significantly higher than that of ADC (p = 0.041). AQP4 mRNA was significantly higher in HGAs than that in LGAs (p < 0.01); there was less AQP9 mRNA and no AQP1 mRNA in LGAs and HGAs groups (p > 0.05); ADC value showed a negative correlation with AQP4 mRNA (r = -0.357; p = 0.024). UHBV-ADC value positively correlated with the AQP4 mRNA (r = 0.646; p < 0.01). UHBV-DWI allowed for a more accurate grading of cerebral astrocytoma than DWI, and UHBV-ADC value may be related with the AQP4 mRNA levels. UHBV-DWI could be of value in the assessment of astrocytoma. Advances in knowledge: UHBV-DWI generated by multi UHBV could have particular value for astrocytoma grading, and the level of AQP4 mRNA might be potentially linked to the change of UHBV-DWI parameter, and we might find the exact reason for the difference of UHBV-ADC between the LGAs and HGAs.
Han, Xu; Suo, Shiteng; Sun, Yawen; Zu, Jinyan; Qu, Jianxun; Zhou, Yan; Chen, Zengai; Xu, Jianrong
2017-03-01
To compare four methods of region-of-interest (ROI) placement for apparent diffusion coefficient (ADC) measurements in distinguishing low-grade gliomas (LGGs) from high-grade gliomas (HGGs). Two independent readers measured ADC parameters using four ROI methods (single-slice [single-round, five-round and freehand] and whole-volume) on 43 patients (20 LGGs, 23 HGGs) who had undergone 3.0 Tesla diffusion-weighted imaging and time required for each method of ADC measurements was recorded. Intraclass correlation coefficients (ICCs) were used to assess interobserver variability of ADC measurements. Mean and minimum ADC values and time required were compared using paired Student's t-tests. All ADC parameters (mean/minimum ADC values of three single-slice methods, mean/minimum/standard deviation/skewness/kurtosis/the10 th and 25 th percentiles/median/maximum of whole-volume method) were correlated with tumor grade (low versus high) by unpaired Student's t-tests. Discriminative ability was determined by receiver operating characteristic curves. All ADC measurements except minimum, skewness, and kurtosis of whole-volume ROI differed significantly between LGGs and HGGs (all P < 0.05). Mean ADC value of single-round ROI had the highest effect size (0.72) and the greatest areas under the curve (0.872). Three single-slice methods had good to excellent ICCs (0.67-0.89) and the whole-volume method fair to excellent ICCs (0.32-0.96). Minimum ADC values differed significantly between whole-volume and single-round ROI (P = 0.003) and, between whole-volume and five-round ROI (P = 0.001). The whole-volume method took significantly longer than all single-slice methods (all P < 0.001). ADC measurements are influenced by ROI determination methods. Whole-volume histogram analysis did not yield better results than single-slice methods and took longer. Mean ADC value derived from single-round ROI is the most optimal parameter for differentiating LGGs from HGGs. 3 J. Magn. Reson. Imaging 2017;45:722-730. © 2016 International Society for Magnetic Resonance in Medicine.
World Antibody-Drug Conjugate Summit, October 15-16, 2013, San Francisco, CA.
Klinguer-Hamour, Christine; Strop, Pavel; Shah, Dhaval K; Ducry, Laurent; Xu, April; Beck, Alain
2014-01-01
The World Antibody-Drug Conjugate (WADC) Summits organized by Hanson Wade are currently the largest meetings fully dedicated to ADCs. The first global ADC Summit was organized in Boston in October 2010. Since 2011, two WADC are held every year in Frankfurt and San Francisco, respectively. The 2013 WADC San Francisco event was structured around plenary sessions with keynote speakers from AbbVie, Agensys, ImmunoGen, Immunomedics, Genentech, Pfizer and Seattle Genetics. Parallel tracks were also organized addressing ADC discovery, development and optimization of chemistry, manufacturing and control (CMC) issues. Discovery and process scientists, regulatory experts (US Food and Drug Administration), academics and clinicians were present, including representatives from biotechnology firms (Concortis, CytomX Therapeutics, Glykos, Evonik, Igenica, Innate Pharma, Mersana Therapeutics, Polytherics, Quanta Biodesign, Redwood Bioscience, Sutro Biopharma, SynAffix), pharmaceutical companies (Amgen, Genmab, Johnson and Johnson, MedImmune, Novartis, Progenics, Takeda) and contract research or manufacturing organizations (Baxter, Bayer, BSP Pharmaceuticals, Fujifilm/Diosynth, Lonza, Pierre Fabre Contract Manufacturing, Piramal, SAFC, SafeBridge).
Zhang, Lu; Ouyang, Xing; Shao, Xiaopeng; Zhao, Jian
2016-06-27
Performance degradation induced by the DC components at the output of real-time analogue-to-digital converter (ADC) is experimentally investigated for optical fast-OFDM receiver. To compensate this degradation, register transfer level (RTL) circuits for real-time digital DC blocker with 20GS/s throughput are proposed and implemented in field programmable gate array (FPGA). The performance of the proposed real-time digital DC blocker is experimentally investigated in a 15Gb/s optical fast-OFDM system with intensity modulation and direct detection over 40 km standard single-mode fibre. The results show that the fixed-point DC blocker has negligible performance penalty compared to the offline floating point one, and can overcome the error floor of the fast OFDM receiver caused by the DC components from the real-time ADC output.
Midha, Anita; Dearden, Simon; McCormack, Rose
2015-01-01
Mutations in the epidermal growth factor receptor (EGFR) gene are commonly observed in non-small-cell lung cancer (NSCLC), particularly in tumors of adenocarcinoma (ADC) histology (NSCLC/ADC). Robust data exist regarding the prevalence of EGFR mutations in Western and Asian patients with NSCLC/ADC, yet there is a lack of data for patients of other ethnicities. This review collated available data with the aim of creating a complete, global picture of EGFR mutation frequency in patients with NSCLC/ADC by ethnicity. Worldwide literature reporting EGFR mutation frequency in patients with NSCLC/ADC was reviewed, to create a map of the world populated with EGFR mutation frequency by country (a ‘global EGFR mutMap’). A total of 151 worldwide studies (n=33162 patients with NSCLC/ADC, of which 9749 patients had EGFR mutation-positive NSCLC/ADC) were included. There was substantial variation in EGFR mutation frequency between studies, even when grouped by geographic region or individual country. As expected, the Asia-Pacific NSCLC/ADC subgroup had the highest EGFR mutation frequency (47% [5958/12819; 87 studies; range 20%-76%]) and the lowest EGFR mutation frequency occurred in the Oceania NSCLC/ADC subgroup (12% [69/570; 4 studies; range 7%-36%]); however, comparisons between regions were limited due to the varying sizes of the patient populations studied. In all regional (geographic) subgroups where data were available, EGFR mutation frequency in NSCLC/ADC was higher in women compared with men, and in never-compared with ever-smokers. This review provides the foundation for a global map of EGFR mutation frequency in patients with NSCLC/ADC. The substantial lack of data from several large geographic regions of the world, notably Africa, the Middle East, Central Asia, and Central and South America, highlights a potential lack of routine mutation testing and the need for further investigations in these regions. PMID:26609494
Yu, Shang-Fan; Zheng, Bing; Go, MaryAnn; Lau, Jeff; Spencer, Susan; Raab, Helga; Soriano, Robert; Jhunjhunwala, Suchit; Cohen, Robert; Caruso, Michele; Polakis, Paul; Flygare, John; Polson, Andrew G
2015-07-15
We are interested in identifying mechanisms of resistance to the current generation of antibody-drug conjugates (ADC) and developing ADCs that can overcome this resistance. Pinatuzumab vedotin (anti-CD22-vc-MMAE) and polatuzumab vedotin (anti-CD79b-vc-MMAE) are ADCs that contain the microtubule inhibitor monomethyl auristatin E (MMAE) attached to the antibody by the protease-cleavable linker maleimidocaproyl-valine-citrulline-p-aminobenzoyloxycarbonyl (MC-vc-PAB). Early clinical trial data suggest that these ADCs have promising efficacy for the treatment of non-Hodgkin lymphoma (NHL); however, some patients do not respond or become resistant to the ADCs. Anthracyclines are very effective in NHL, but ADCs containing the anthracycline doxorubicin were not clinically efficacious probably due to the low drug potency and inadequate linker technology. The anthracycline analogue PNU-159682 is thousands of times more cytotoxic than doxorubicin, so we used it to develop a new class of ADCs. We used the same MC-vc-PAB linker and antibody in pinatuzumab vedotin but replaced the MMAE with a derivative of PNU-159682 to make anti-CD22-NMS249 and tested it for in vivo efficacy in xenograft tumors resistant to MMAE-based ADCs. We derived cell lines from in vivo xenograft tumors that were made resistant to anti-CD22-vc-MMAE and anti-CD79b-vc-MMAE. We identified P-gp (ABCB1/MDR1) as the major driver of resistance to the vc-MMAE-based conjugates. Anti-CD22-NMS249 was at least as effective as anti-CD22-vc-MMAE in xenograft models of the parental cell lines and maintained its efficacy in the resistant cell lines. These studies provide proof of concept for an anthracycline-based ADC that could be used to treat B-cell malignancies that are resistant to vc-MMAE conjugates. ©2015 American Association for Cancer Research.
Borren, Alie; Moman, Maaike R; Groenendaal, Greetje; Boeken Kruger, Arto E; van Diest, Paul J; van der Groep, Petra; van der Heide, Uulke A; van Vulpen, Marco; Philippens, Marielle E P
2013-11-01
Focal boosting of prostate tumours to improve outcome, requires accurate tumour delineation. For this, the apparent diffusion coefficient (ADC) derived from diffusion-weighted MR imaging (DWI) seems a useful tool. On voxel level, the relationship between ADC and histological presence of tumour is, however, ambiguous. Therefore, in this study the relationship between ADC and histological variables was investigated on voxel level to understand the strengths and limitations of DWI for prostate tumour delineation. Twelve radical prostatectomy patients underwent a pre-operative 3.0T DWI exam and the ADC was calculated. From whole-mount histological sections cell density and glandular area were retrieved for every voxel. The distribution of all variables was described for tumour, peripheral zone (PZ) and central gland (CG) on regional and voxel level. Correlations between variables and differences between regions were calculated. Large heterogeneity of ADC on voxel level was observed within tumours, between tumours and between patients. This heterogeneity was reflected by the distribution of cell density and glandular area. On regional level, tumour was different from PZ having higher cell density (p = 0.007), less glandular area (p = 0.017) and lower ADCs (p = 0.017). ADC was correlated with glandular area (r = 0.402) and tumour volume (r = -0.608), but not with Gleason score. ADC tended to decrease with increasing cell density (r = -0.327, p = 0.073). On voxel level, correlations between ADC and histological variables varied among patients, for cell density ranging from r = -0.439 to r = 0.261 and for glandular area from r = 0.593 to r = 0.207. The variation in ADC can to a certain extent be explained by the variation in cell density and glandular area. The ADC is highly heterogeneous, which reflects the heterogeneity of malignant and benign prostate tissue. This heterogeneity might however obscure small tumours or parts of tumours. Therefore, DWI has to be used in the context of multiparametric MRI.
Improving H-Q rating curves in temprorary streams by using Acoustic Doppler Current meters
NASA Astrophysics Data System (ADS)
Marchand, P.; Salles, C.; Rodier, C.; Hernandez, F.; Gayrard, E.; Tournoud, M.-G.
2012-04-01
Intermittent rivers pose different challenges to stream rating due to high spatial and temporal gradients. Long dry periods, cut by short duration flush flood events explain the difficulty to obtain reliable discharge data, for low flows as well as for floods: problems occur with standard gauging, zero flow period, etc. Our study aims to test the use of an acoustic Doppler currentmeter (ADC) for improving stream rating curves in small catchments subject to large variations of discharge, solid transport and high eutrophication levels. The study is conducted at the outlet of the river Vène, a small coastal river (67 km2) located close to the city of Montpellier (France). The low flow period lasts for more than 6 month; during this period the river flow is sustained by effluents from urban sewage systems, which allows development of algae and macrophytes in the riverbed. The ADC device (Sontek ®Argonaut SW) is a pulsed Doppler current profiling system designed for measuring water velocity profiles and levels that are used to compute volumetric flow rates. It is designed for shallow waters (less than 4 meter depth). Its main advantages are its low cost and high accuracy (±1% of the measured velocity or ±0.05 m/sec, as reported by the manufacturer). The study will evaluate the improvement in rating curves in an intermittent flow context and the effect of differences in sensitivity between low and high water level, by comparing mean flow velocity obtained by ADC to direct discharges measurements. The study will also report long-term use of ADC device, by considering effects of biofilms, algae and macrophytes, as well as solid transport on the accuracy of the measurements. In conclusion, we show the possibility to improve stream rating and continuous data collection of an intermittent river by using a ADC with some precautions.
A 12b 200kS/s 0.52mA 0.47mm2 Algorithmic A/D Converter for MEMS Applications
NASA Astrophysics Data System (ADS)
Kim, Young-Ju; Choi, Hee-Cheol; Lee, Seung-Hoon; Cho, Dongil “Dan”
This work describes a 12b 200kS/s 0.52mA 0.47mm2 ADC for sensor applications such as motor control, 3-phase power control, and CMOS image sensors simultaneously requiring ultra-low power and small size. The proposed ADC is based on the conventional algorithmic architecture with a recycling signal path to optimize sampling rate, resolution, chip area, and power consumption. The input SHA with eight input channels employs a folded-cascode amplifier to achieve a required DC gain and a high phase margin. A 3-D fully symmetric layout with critical signal lines shielded reduces the capacitor and device mismatch of the multiplying D/A converter while switched-bias power-reduction circuits minimize the power consumption of analog amplifiers. Current and voltage references are integrated on chip with optional off-chip voltage references for low glitch noise. The down-sampling clock signal selects the sampling rate of 200kS/s and 10kS/s with a further reduced power depending on applications. The prototype ADC in a 0.18μm n-well 1P6M CMOS process demonstrates a maximum measured DNL and INL within 0.40 LSB and 1.97 LSB and shows a maximum SNDR and SFDR of 55dB and 70dB at all sampling frequencies up to 200kS/s, respectively. The ADC occupies an active die area of 0.47mm2 and consumes 0.94mW at 200kS/s and 0.63mW at 10kS/s with a 1.8V supply.
Tummala, Seshu B; Welker, Neil E; Papoutsakis, Eleftherios T
2003-03-01
We investigated the effect of antisense RNA (asRNA) structural properties on the downregulation efficacy of enzymes in the acetone-formation pathway (acetoacetate decarboxylase [AADC] and coenzyme A-transferase [CoAT]) of Clostridium acetobutylicum strain ATCC 824. First, we generated three strains, C. acetobutylicum ATCC 824 (pADC38AS), 824(pADC68AS), and 824(pADC100AS), which contain plasmids that produce asRNAs of various lengths against the AADC (adc) transcript. Western analysis showed that all three strains exhibit low levels of AADC compared to the plasmid control [ATCC 824(pSOS95del)]. By using computational algorithms, the three different asRNAs directed toward AADC, along with previously reported clostridial asRNAs, were examined for structural features (free nucleotides and components). When the normalized metrics of these structural features were plotted against percent downregulation, only the component/nucleotide ratio correlated well with in vivo asRNA effectiveness. Despite the significant downregulation of AADC in these strains, there were no concomitant effects on acetone formation. These findings suggest that AADC does not limit acetone formation and, thus, we targeted next the CoAT. Using the component/nucleotide ratio as a selection parameter, we developed three strains [ATCC 824 (pCTFA2AS), 824(pCTFB1AS), and 824(pCOAT11AS)] which express asRNAs to downregulate either or both of the CoAT subunits. Compared to the plasmid control strain, these strains produced substantially low levels of acetone and butanol and Western blot analyses showed significantly low levels of both CoAT subunits. These results show that CoAT is the rate-limiting enzyme in acetone formation and strengthen the hypothesis that the component/nucleotide ratio is a predictive indicator of asRNA effectiveness.
Tummala, Seshu B.; Welker, Neil E.; Papoutsakis, Eleftherios T.
2003-01-01
We investigated the effect of antisense RNA (asRNA) structural properties on the downregulation efficacy of enzymes in the acetone-formation pathway (acetoacetate decarboxylase [AADC] and coenzyme A-transferase [CoAT]) of Clostridium acetobutylicum strain ATCC 824. First, we generated three strains, C. acetobutylicum ATCC 824 (pADC38AS), 824(pADC68AS), and 824(pADC100AS), which contain plasmids that produce asRNAs of various lengths against the AADC (adc) transcript. Western analysis showed that all three strains exhibit low levels of AADC compared to the plasmid control [ATCC 824(pSOS95del)]. By using computational algorithms, the three different asRNAs directed toward AADC, along with previously reported clostridial asRNAs, were examined for structural features (free nucleotides and components). When the normalized metrics of these structural features were plotted against percent downregulation, only the component/nucleotide ratio correlated well with in vivo asRNA effectiveness. Despite the significant downregulation of AADC in these strains, there were no concomitant effects on acetone formation. These findings suggest that AADC does not limit acetone formation and, thus, we targeted next the CoAT. Using the component/nucleotide ratio as a selection parameter, we developed three strains [ATCC 824 (pCTFA2AS), 824(pCTFB1AS), and 824(pCOAT11AS)] which express asRNAs to downregulate either or both of the CoAT subunits. Compared to the plasmid control strain, these strains produced substantially low levels of acetone and butanol and Western blot analyses showed significantly low levels of both CoAT subunits. These results show that CoAT is the rate-limiting enzyme in acetone formation and strengthen the hypothesis that the component/nucleotide ratio is a predictive indicator of asRNA effectiveness. PMID:12618456
Kim, Jin You; Suh, Hie Bum; Kang, Hyun Jung; Shin, Jong Ki; Choo, Ki Seok; Nam, Kyung Jin; Lee, Seok Won; Jung, Young Lae; Bae, Young Tae
2016-05-01
The purpose of this study was to investigate prospectively whether the apparent diffusion coefficients (ADCs) of both breast cancer and normal fibroglandular tissue vary with the menstrual cycle and menopausal status. Institutional review board approval was obtained, and informed consent was obtained from each participant. Fifty-seven women (29 premenopausal, 28 postmenopausal) with newly diagnosed breast cancer underwent diffusion-weighted imaging twice (interval 12-20 days) before surgery. Two radiologists independently measured ADC of breast cancer and normal contralateral breast tissue, and we quantified the differences according to the phases of menstrual cycle and menopausal status. With normal fibroglandular tissue, ADC was significantly lower in postmenopausal than in premenopausal women (P = 0.035). In premenopausal women, ADC did not differ significantly between proliferative and secretory phases in either breast cancer or normal fibroglandular tissue (P = 0.969 and P = 0.519, respectively). In postmenopausal women, no significant differences were found between ADCs measured at different time intervals in either breast cancer or normal fibroglandular tissue (P = 0.948 and P = 0.961, respectively). The within-subject variability of the ADC measurements was quantified using the coefficient of variation (CV) and was small: the mean CVs of tumor ADC were 2.90 % (premenopausal) and 3.43 % (postmenopausal), and those of fibroglandular tissue ADC were 4.37 % (premenopausal) and 2.55 % (postmenopausal). Both intra- and interobserver agreements were excellent for ADC measurements, with intraclass correlation coefficients in the range of 0.834-0.974. In conclusion, the measured ADCs of breast cancer and normal fibroglandular tissue were not affected significantly by menstrual cycle, and the measurements were highly reproducible both within and between observers.
Nowakowski, Andrzej M.; Powell, Ned; McCluggage, W. Glenn; Pirog, Edyta C.; Collas De Souza, Sabrina; Tjalma, Wiebren A.; Rosenlund, Mats; Fiander, Alison; Castro Sánchez, Maria; Damaskou, Vasileia; Joura, Elmar A.; Kirschner, Benny; Koiss, Robert; O'Leary, John; Quint, Wim; Reich, Olaf; Torné, Aureli; Wells, Michael; Rob, Lukas; Kolomiets, Larisa; Molijn, Anco; Savicheva, Alevtina; Shipitsyna, Elena; Rosillon, Dominique; Jenkins, David
2015-01-01
Cervical glandular neoplasias (CGN) present a challenge for cervical cancer prevention due to their complex histopathology and difficulties in detecting preinvasive stages with current screening practices. Reports of human papillomavirus (HPV) prevalence and type‐distribution in CGN vary, providing uncertain evidence to support prophylactic vaccination and HPV screening. This study [108288/108290] assessed HPV prevalence and type‐distribution in women diagnosed with cervical adenocarcinoma in situ (AIS, N = 49), adenosquamous carcinoma (ASC, N = 104), and various adenocarcinoma subtypes (ADC, N = 461) from 17 European countries, using centralised pathology review and sensitive HPV testing. The highest HPV‐positivity rates were observed in AIS (93.9%), ASC (85.6%), and usual‐type ADC (90.4%), with much lower rates in rarer ADC subtypes (clear‐cell: 27.6%; serous: 30.4%; endometrioid: 12.9%; gastric‐type: 0%). The most common HPV types were restricted to HPV16/18/45, accounting for 98.3% of all HPV‐positive ADC. There were variations in HPV prevalence and ADC type‐distribution by country. Age at diagnosis differed by ADC subtype, with usual‐type diagnosed in younger women (median: 43 years) compared to rarer subtypes (medians between 57 and 66 years). Moreover, HPV‐positive ADC cases were younger than HPV‐negative ADC. The six years difference in median age for women with AIS compared to those with usual‐type ADC suggests that cytological screening for AIS may be suboptimal. Since the great majority of CGN are HPV16/18/45‐positive, the incorporation of prophylactic vaccination and HPV testing in cervical cancer screening are important prevention strategies. Our results suggest that special attention should be given to certain rarer ADC subtypes as most appear to be unrelated to HPV. PMID:26096203
Hanemaaijer, Saskia H; van Gijn, Stephanie E; Oosting, Sjoukje F; Plaat, Boudewijn E C; Moek, Kirsten L; Schuuring, Ed M; van der Laan, Bernard F A M; Roodenburg, Jan L N; van Vugt, Marcel A T M; van der Vegt, Bert; Fehrmann, Rudolf S N
2018-05-01
For patients with recurrent or metastatic head and neck squamous cell carcinoma (HNSCC) palliative treatment options that improve overall survival are limited. The prognosis in this group remains poor and there is an unmet need for new therapeutic options. An emerging class of therapeutics, targeting tumor-specific antigens, are antibodies bound to a cytotoxic agent, known as antibody-drug conjugates (ADCs). The aim of this study was to prioritize ADC targets in HNSCC. With a systematic search, we identified 55 different ADC targets currently targeted by registered ADCs and ADCs under clinical evaluation. For these 55 ADC targets, protein overexpression was predicted in a dataset containing 344 HNSCC mRNA expression profiles by using a method called functional genomic mRNA profiling. The ADC target with the highest predicted overexpression was validated by performing immunohistochemistry (IHC) on an independent tissue microarray containing 414 HNSCC tumors. The predicted top 5 overexpressed ADC targets in HNSCC were: glycoprotein nmb (GPNMB), SLIT and NTRK-like family member 6, epidermal growth factor receptor, CD74 and CD44. IHC validation showed combined cytoplasmic and membranous GPNMB protein expression in 92.0% of the cases. Strong expression was seen in 65.9% of the cases. In addition, 86.5% and 67.7% of cases showed ≥5% and >25% GPNMB positive tumor cells, respectively. This study provides a data-driven prioritization of ADCs targets that will facilitate clinicians and drug developers in deciding which ADC should be taken for further clinical evaluation in HNSCC. This might help to improve disease outcome of HNSCC patients. Copyright © 2018 Elsevier Ltd. All rights reserved.
Characterization of diffuse orbital mass using Apparent diffusion coefficient in 3-tesla MRI.
ElKhamary, Sahar M; Galindo-Ferreiro, Alicia; AlGhafri, Laila; Khandekar, Rajiv; Schellini, Silvana Artioli
2018-01-01
To evaluate if the apparent diffusion coefficient (ADC) value in diffusion-weighted magnetic resonance imaging (DW-MRI) improves the diagnostic accuracy of diffuse orbital masses. ADC DW-MRI was used to evaluate cases of diffuse orbital masses at our institution from 2000 to 2015. Lesions were grouped according to histopathologic diagnosis as, benign, pre-malignant and malignant. Lymphoproliferative lesions were further subgrouped as lymphoma or other lymphoproliferative lesions. The validity of the ADC value for the diffuse orbital mass was compared between groups. The area under curve (AUC) was also calculated. Thirty-nine cases of diffuse orbital masses were evaluated. The median ADC was 0.58 (25% quartile 0.48; minimum: 0.45; maximum: 1.72 × 10 (-3) ) for the malignant tumors and 1.19 (25% quartile 0.7; minimum: 0.5; maximum: 1.95 × 10 (-3) mm (2) s (-1) ) for benign lesions. This difference in ADC between lesions was statistically significant (Mann Whitney U test P < 0.001). The median ADC was 0.51 (25% quartile 0.48) for lymphomas and 0.9 (25% quartile 0.7) for other lymphoproliferative lesions. This difference in ADC was statistically significant (Mann Whitney U test P = 0.02). An ADC value of 0.8 × 10 (-3) mm (2) s (-1) was noted as the ideal threshold value for differentiating malignant from benign diffuse orbital masses. The validity of ADC in predicting a malignant or benign diffuse orbital mass had a sensitivity of 87%, specificity of 67% and accuracy of 88%. ADC is a promising imaging metric to characterize malignant and benign diffuse orbital masses and to distinguish lymphomas from other non-lymphoproliferative lesions.
Drug-conjugated antibodies for the treatment of cancer
Lambert, John M
2013-01-01
Despite considerable effort, application of monoclonal antibody technology has had only modest success in improving treatment outcomes in patients with solid tumours. Enhancing the cancer cell-killing activity of antibodies through conjugation to highly potent cytotoxic ‘payloads’ to create antibody–drug conjuates (ADCs) offers a strategy for developing anti-cancer drugs of great promise. Early ADCs exhibited side-effect profiles similar to those of ‘classical’ chemotherapeutic agents and their performance in clinical trials in cancer patients was generally poor. However, the recent clinical development of ADCs that have highly potent tubulin-acting agents as their payloads have profoundly changed the outlook for ADC technology. Twenty-five such ADCs are in clinical development and one, brentuximab vedotin, was approved by the FDA in August, 2011, for the treatment of patients with Hodgkin's lymphoma and patients with anaplastic large cell lymphoma, based on a high rate of durable responses in single arm phase II clinical trials. More recently, a second ADC, trastuzumab emtansine, has shown excellent anti-tumour activity with the presentation of results of a 991-patient randomized phase III trial in patients with HER2-positive metastatic breast cancer. Treatment with this ADC (single agent) resulted in a significantly improved progression-free survival of 9.6 months compared with 6.4 months for lapatinib plus capecitabine in the comparator arm and significantly prolonged overall survival. Besides demonstrating excellent efficacy, these ADCs were remarkably well tolerated. Thus these, and other ADCs in development, promise to achieve the long sought goal of ADC technology, that is, of having compounds with high anti-tumour activity at doses where adverse effects are generally mild. PMID:23173552
Zn2+ Uptake in Streptococcus pyogenes: Characterization of adcA and lmb Null Mutants.
Tedde, Vittorio; Rosini, Roberto; Galeotti, Cesira L
2016-01-01
An effective regulation of metal ion homeostasis is essential for the growth of microorganisms in any environment and in pathogenic bacteria is strongly associated with their ability to invade and colonise their hosts. To gain a better insight into zinc acquisition in Group A Streptococcus (GAS) we characterized null deletion mutants of the adcA and lmb genes of Streptococcus pyogenes strain MGAS5005 encoding the orthologues of AdcA and AdcAII, the two surface lipoproteins with partly redundant roles in zinc homeostasis in Streptococcus pneumoniae. Null adcA and lmb mutants were analysed for their capability to grow in zinc-depleted conditions and were found to be more susceptible to zinc starvation, a phenotype that could be rescued by the addition of Zn2+ ions to the growth medium. Expression of AdcA, Lmb and HtpA, the polyhistidine triad protein encoded by the gene adjacent to lmb, during growth under conditions of limited zinc availability was examined by Western blot analysis in wild type and null mutant strains. In the wild type strain, AdcA was always present with little variation in expression levels between conditions of excess or limited zinc availability. In contrast, Lmb and HtpA were expressed at detectable levels only during growth in the presence of low zinc concentrations or in the null adcA mutant, when expression of lmb is required to compensate for the lack of adcA expression. In the latter case, Lmb and HtpA were overexpressed by several fold, thus indicating that also in GAS AdcA is a zinc-specific importer and, although it shares this function with Lmb, the two substrate-binding proteins do not show fully overlapping roles in zinc homeostasis.
Cancer in HIV-infected Persons from the Caribbean, Central and South America
Fink, Valeria I.; Shepherd, Bryan E.; Cesar, Carina; Krolewiecki, Alejandro; Wehbe, Firas; Cortés, Claudia P.; Crabtree-Ramírez, Brenda; Padgett, Denis; Shafaee, Maryam; Schechter, Mauro; Gotuzzo, Eduardo; Bacon, Melanie; McGowan, Catherine; Cahn, Pedro; Masys, Daniel
2011-01-01
Background HIV infected individuals have heightened cancer risk. With the advent of HAART, the frequency of some AIDS defining cancers (ADC) has decreased while certain non-AIDS defining cancers (NADC) are becoming more frequent. Cancers among HIV-infected individuals in Latin American and the Caribbean have not yet been carefully studied. Methods Cancer cases among the Caribbean, Central and South American network for HIV Research (CCASAnet) cohort were identified reviewing clinical records and preexisting databases. Results There were 406 cancers reported: 331 ADC (224 Kaposi´s sarcomas and 98 non Hodgkin lymphomas). Most frequent NADC (n=75) were Hodgkin lymphoma and skin cancers. Seventy-three percent of NADC and 45% of ADC were diagnosed >1 year after HIV diagnosis. 56% of ADC occurred before HAART start. Median time from HAART start until cancer diagnosis was 2.5 years for NADC and 0.5 years for ADC (p=<0.001). Within 3372 HAART starters, 158 were diagnosed with 165 cancers (82.4% ADC); 85 cases were previous to or concomitant with HAART initiation. Incidence of cancer after HAART initiation in 8080 person-years of follow-up was 7.2 per 1000 person-years (95%CI= 5.5–9.3) for ADC and 2.7 (95%CI= 1.8–4.1) for NADC; incidence was higher in the first two months, particularly for ADC (47.6). A pre-HAART ADC was a predictor of mortality after adjusting for age, sex, and CD4 at HAART initiation. Conclusions ADC were the most frequent cancers in this region and were often diagnosed close to HIV diagnosis and HAART start. Incidence of cancer was highest around HAART initiation. PMID:21239992
Agarwal, Khushbu; Sharma, Uma; Sah, Rani G; Mathur, Sandeep; Hari, Smriti; Seenu, Vurthaluru; Parshad, Rajinder; Jagannathan, Naranamangalam R
2017-10-01
The potential of diffusion weighted imaging (DWI) in assessing pathologic response and surgical margins in locally advanced breast cancer patients (n=38) undergoing neoadjuvant chemotherapy was investigated. DWI was performed at pre-therapy (Tp0), after I (Tp1) and III (Tp3) NACT at 1.5T. Apparent diffusion coefficient (ADC) of whole tumor (ADC WT ), solid tumor (ADC ST ), intra-tumoral necrosis (ADC Nec ) was determined. Further, ADC of 6 consecutive shells (5mm thickness each) including tumor margin to outside tumor margins (OM1 to OM5) was calculated and the data analyzed to define surgical margins. Of 38 patients, 6 were pathological complete responders (pCR), 19 partial responders (pPR) and 13 were non-responders (pNR). Significant increase was observed in ADC ST and ADC WT in pCR and pPR following therapy. Pre-therapy ADC was significantly lower in pCR compared to pPR and pNR indicating the heterogeneous nature of tumor which may affect drug perfusion and consequently the response. ADC of outside margins (OM1, OM2, and OM3) was significantly different among pCR, pPR and pNR at Tp3 which may serve as response predictive parameter. Further, at Tp3, ADC of outside margins (OM1, OM2, and OM3) was significantly lower compared to that seen at Tp0 in pCR, indicating the presence of residual disease in these shells. Pre-surgery information may serve as a guide to define cancer free margins and the extent of residual disease which may be useful in planning breast conservation surgery. Copyright © 2017 Elsevier Inc. All rights reserved.
Ito, Katsuyoshi; Hayashida, Minoru; Kanki, Akihiko; Yamamoto, Akira; Tamada, Tsutomu; Yoshida, Koji; Tanabe, Masahiro
2018-05-17
To evaluate dynamic changes in apparent diffusion coefficient (ADC) values of the kidney at different time points during the cardiac cycle using electrocardiographic (ECG)-triggered diffusion-weighted MR imaging in normal subjects, and to elucidate the differences in ADC values between the right and left kidneys during a cardiac cycle. The study was approved by our institutional review board and informed consent was obtained from subjects. Twenty healthy volunteers who underwent ECG-triggered diffusion-weighted MR imaging of the kidney were included. The differences in ADC values of each kidney during different cardiac phases were compared. Additionally, the differences in maximum and minimum ADC values between the right and left kidney were also evaluated. ADC values in the right and left kidney changed significantly during the cardiac cycle (P < 0.00001). Maximum and minimum ADC values during the cardiac cycle of the left kidney were significantly higher (P = 0.026 and 0.017, respectively) than those of the right kidney. Maximum ADC value in the left kidney had a significantly strong positive correlation with the left renal vein ratio (r = 0.83, P < 0.00001). In the right kidney, maximum ADC showed a weakly positive correlation with the diameter of the right renal vein (r = 0.45, P = 0.048). ADC values of the kidney obtained using ECG-triggered diffusion-weighted MR imaging change significantly during the cardiac cycle. Maximum (systolic) ADC during the cardiac cycle of the left kidney was significantly higher than that of the right kidney, probably due to the anatomical difference in the renal vein. Copyright © 2018 Elsevier Inc. All rights reserved.
Metal Organic Framework Micro/Nanopillars of Cu(BTC)·3H₂O and Zn(ADC)·DMSO.
Kojtari, Arben; Ji, Hai-Feng
2015-04-09
In this work, we report the optical and thermal properties of Cu(BTC)·3H₂O (BTC = 1,3,5-benzenetricarboxylic acid) and Zn(ADC)·DMSO (ADC = 9,10- anthracenedicarboxylic acid, DMSO = dimethyl sulfoxide) metal-organic frameworks (MOFs) micro/nanopillars. The morphologies of MOFs on surfaces are most in the form of micro/nanopillars that were vertically oriented on the surface. The size and morphology of the pillars depend on the evaporation time, concentration, solvent, substrate, and starting volume of solutions. The crystal structures of the nanopillars and micropillars are the same, confirmed by powder XRD. Zn(ADC)·DMSO pillars have a strong blue fluorescence. Most of ADC in the pillars are in the form of monomers, which is different from ADC in the solid powder.
Characterization of arginine decarboxylase from Dianthus caryophyllus.
Ha, Byung Hak; Cho, Ki Joon; Choi, Yu Jin; Park, Ky Young; Kim, Kyung Hyun
2004-04-01
Arginine decarboxylase (ADC, EC 4.1.1.9) is a key enzyme in the biosynthesis of polyamines in higher plants, whereas ornithine decarboxylase represents the sole pathway of polyamine biosynthesis in animals. Previously, we characterized a genomic clone from Dianthus caryophyllus, in which the deduced polypeptide of ADC was 725 amino acids with a molecular mass of 78 kDa. In the present study, the ADC gene was subcloned into the pGEX4T1 expression vector in combination with glutathione S-transferase (GST). The fusion protein GST-ADC was water-soluble and thus was purified by sequential GSTrap-arginine affinity chromatography. A thrombin-mediated on-column cleavage reaction was employed to release free ADC from GST. Hiload superdex gel filtration FPLC was then used to obtain a highly purified ADC. The identity of the ADC was confirmed by immunoblot analysis, and its specific activity with respect to (14)C-arginine decarboxylation reaction was determined to be 0.9 CO(2) pkat mg(-1) protein. K(m) and V(max) of the reaction between ADC and the substrate were 0.077 +/- 0.001 mM and 6.0 +/- 0.6 pkat mg(-1) protein, respectively. ADC activity was reduced by 70% in the presence of 0.1 mM Cu(2+) or CO(2+), but was only marginally affected by Mg(2+), or Ca(2+) at the same concentration. Moreover, spermine at 1 mM significantly reduced its activity by 30%.
Song, Y; Yoon, Y C; Chong, Y; Seo, S W; Choi, Y-L; Sohn, I; Kim, M-J
2017-08-01
To compare the abilities of conventional magnetic resonance imaging (MRI) and apparent diffusion coefficient (ADC) in differentiating between benign and malignant soft-tissue tumours (STT). A total of 123 patients with STT who underwent 3 T MRI, including diffusion-weighted imaging (DWI), were retrospectively analysed using variate conventional MRI parameters, ADC mean and ADC min . For the all-STT group, the correlation between the malignant STT conventional MRI parameters, except deep compartment involvement, compared to those of benign STT were statistically significant with univariate analysis. Maximum diameter of the tumour (p=0.001; odds ratio [OR], 8.97) and ADC mean (p=0.020; OR, 4.30) were independent factors with multivariate analysis. For the non-myxoid non-haemosiderin STT group, signal heterogeneity on axial T1-weighted imaging (T1WI; p=0.017), ADC mean , and ADC min (p=0.001, p=0.001), showed significant differences with univariate analysis between malignancy and benignity. Signal heterogeneity in axial T1WI (p=0.025; OR, 12.64) and ADC mean (p=0.004; OR, 33.15) were independent factors with multivariate analysis. ADC values as well as conventional MRI parameters were useful in differentiating between benign and malignant STT. The ADC mean was the most powerful diagnostic parameter in non-myxoid non-haemosiderin STT. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Kim, Soo-Yeon; Shin, Jaewook; Kim, Dong-Hyun; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; You, Jai Kyung; Kim, Min Jung
2018-03-06
To investigate the correlation between conductivity and ADC in invasive ductal carcinoma according to the presence of necrosis on MRI. Eighty-one women with invasive ductal carcinoma ≥1 cm on T2-weighted fast spin echo sequence of preoperative MRI were included. Phase-based MR electric properties tomography was used to reconstruct conductivity. Mean ADC was measured. Necrosis was defined as an area with very high T2 signal intensity. The relationship between conductivity and ADC was examined using Spearman's correlation coefficient (r). Multiple linear regression analysis was performed to identify factors associated with conductivity or ADC. In the total group, conductivity showed negative correlation with ADC (r = -0.357, p = 0.001). This correlation was maintained in the subgroup without necrosis (n = 53, r = -0.455, p = 0.001), but not in the subgroup with necrosis (n = 28, r = -0.080, p = 0.687). The correlation between the two parameters was different according to necrosis (r = -0.455 vs -0.080, p = 0.047). HER2 enriched subtype was independently associated with conductivity (p = 0.029). Necrosis on MRI was independently associated with ADC (p = 0.027). Conductivity shows negative correlation with ADC that is abolished by the presence of necrosis on MRI. • Electric conductivity showed negative correlation with ADC • However, the correlation was abolished by the presence of necrosis on MRI • HER2-enriched subtype was independently associated with conductivity • Necrosis on MRI was independently associated with ADC.
Babsky, Andriy M; Topper, Stephen; Zhang, Hong; Gao, Yong; James, Judy R; Hekmatyar, Shahryar K; Bansal, Navin
2008-03-01
The mechanism of water and sodium apparent diffusion coefficient (ADC) changes in rat skeletal muscle during global ischemia was examined by in vivo 1H and 23Na magnetic resonance spectroscopy (MRS). The ADCs of Na+ and water are expected to have similar characteristics because sodium is present as an aqua-cation in tissue. The shift reagent, TmDOTP5(-), was used to separate intra- and extracellular sodium (Na+i and Na+e, respectively) signals. Water, total tissue sodium (Na+t), Na+i, and Na+e ADCs were measured before and 1, 2, 3, and 4 hr after ischemia. Contrary to the general perception, Na+i and Na+e ADCs were identical before ischemia. Thus, ischemia-induced changes in Na+e ADC cannot be explained by a simple change in the size of relative intracellular or extracellular space. Na+t and Na+e ADCs decreased after 2-4 hr of ischemia, while water and Na+i ADC remained unchanged. The correlation between Na+t and Na+e ADCs was observed because of high Na+e concentration. Similarly, the correlation between water and Na+i ADCs was observed because cells occupy 80% of the tissue space in the skeletal muscle. Ischemia also caused an increase in the Na+i and an equal decrease in Na+e signal intensity due to cessation of Na+/K+-ATPase function. (c) 2008 Wiley-Liss, Inc.
Li, Ying; Mei, Lihong; Qiang, Jinwei; Ju, Shuai; Zhao, Shuhui
2016-12-01
Portal-systemic encephalopathy (PSE) is classified as type B hepatic encephalopathy. Portal-systemic shunting rather than liver dysfunction is the main cause of PSE in chronic hepatic schistosomiasis japonicum (HSJ) patients. Owing to lack of detectable evidence of intrinsic liver disease, chronic HSJ patients with PSE are frequently clinically undetected or misdiagnosed, especially chronic HSJ patients with covert PSE (subclinical encephalopathy). In this study, we investigated whether magnetic resonance spectroscopy (MRS) could be a useful tool for diagnosing PSE in chronic HSJ patients. Magnetic resonance (MR) T1-weighted imaging, diffusion-weighted imaging, and MRS were performed in 41 chronic HSJ patients with suspected PSE and in 21 age-matched controls. The T1 signal intensity index (T1SI) and apparent diffusion coefficient (ADC) value were obtained in the Globus pallidus. Liver function was also investigated via serum ammonia and liver function tests. Higher T1SI and ADC values, increased lactate and glutamine levels, and decreased myo-inositol were found in the bilateral Globus pallidus in chronic HSJ patients with PSE. No significantly abnormal serum ammonia or liver function tests were observed in chronic HSJ patients with PSE. On the basis of these findings, we propose a diagnostic procedure for PSE in chronic HSJ patients. This study reveals that MRS can be useful for diagnosing PSE in chronic HSJ patients.
Lorin, Clarisse; Vanloubbeeck, Yannick; Baudart, Sébastien; Ska, Michaël; Bayat, Babak; Brauers, Geoffroy; Clarinval, Géraldine; Donner, Marie-Noëlle; Marchand, Martine; Koutsoukos, Marguerite; Mettens, Pascal; Cohen, Joe; Voss, Gerald
2015-01-01
HIV-1-specific CD4+ and CD8+ T lymphocytes are important for HIV-1 replication control. F4/AS01 consists of F4 recombinant fusion protein (containing clade B Gag/p24, Pol/RT, Nef and Gag/p17) formulated in AS01 Adjuvant System, and was shown to induce F4-specific polyfunctional CD4+ T-cell responses in humans. While replication-incompetent recombinant HIV-1/SIV antigen-expressing human adenoviral vectors can elicit high-frequency antigen-specific CD8+ T-cell responses, their use is hampered by widespread pre-existing immunity to human serotypes. Non-human adenovirus serotypes associated with lower prevalence may offer an alternative strategy. We evaluated the immunogenicity of AdC7-GRN ('A'), a recombinant chimpanzee adenovirus type 7 vector expressing clade B Gag, RT and Nef, and F4/AS01 ('P'), when delivered intramuscularly in homologous (PP or AA) and heterologous (AAPP or PPAA) prime-boost regimens, in macaques and mice. Vaccine-induced HIV-1-antigen-specific T cells in peripheral blood (macaques), liver, spleen, and intestinal and genital mucosa (mice) were characterized by intracellular cytokine staining. Vaccine-specific IgG antibodies (macaques) were detected using ELISA. In macaques, only the heterologous prime-boost regimens induced polyfunctional, persistent and balanced CD4+ and CD8+ T-cell responses specific to each HIV-1 vaccine antigen. AdC7-GRN priming increased the polyfunctionality of F4/AS01-induced CD4+ T cells. Approximately 50% of AdC7-GRN-induced memory CD8+ T cells exhibited an effector-memory phenotype. HIV-1-specific antibodies were detected with each regimen. In mice, antigen-specific CD4+ and CD8+ T-cell responses were detected in the mucosal and systemic anatomical compartments assessed. When administered in heterologous prime-boost regimens, AdC7-GRN and F4/AS01 candidate vaccines acted complementarily in inducing potent and persistent peripheral blood HIV-1-specific CD4+ and CD8+ T-cell responses and antibodies in macaques. Besides, adenoviral vector priming modulated the cytokine-expression profile of the protein-induced CD4+ T cells. Each regimen induced HIV-1-specific T-cell responses in systemic/local tissues in mice. This suggests that prime-boost regimens combining adjuvanted protein and low-seroprevalent chimpanzee adenoviral vectors represent an attractive vaccination strategy for clinical evaluation.
Lorin, Clarisse; Vanloubbeeck, Yannick; Baudart, Sébastien; Ska, Michaël; Bayat, Babak; Brauers, Geoffroy; Clarinval, Géraldine; Donner, Marie-Noëlle; Marchand, Martine; Koutsoukos, Marguerite; Mettens, Pascal; Cohen, Joe; Voss, Gerald
2015-01-01
HIV-1-specific CD4+ and CD8+ T lymphocytes are important for HIV-1 replication control. F4/AS01 consists of F4 recombinant fusion protein (containing clade B Gag/p24, Pol/RT, Nef and Gag/p17) formulated in AS01 Adjuvant System, and was shown to induce F4-specific polyfunctional CD4+ T-cell responses in humans. While replication-incompetent recombinant HIV-1/SIV antigen-expressing human adenoviral vectors can elicit high-frequency antigen-specific CD8+ T-cell responses, their use is hampered by widespread pre-existing immunity to human serotypes. Non-human adenovirus serotypes associated with lower prevalence may offer an alternative strategy. We evaluated the immunogenicity of AdC7-GRN (‘A’), a recombinant chimpanzee adenovirus type 7 vector expressing clade B Gag, RT and Nef, and F4/AS01 (‘P’), when delivered intramuscularly in homologous (PP or AA) and heterologous (AAPP or PPAA) prime-boost regimens, in macaques and mice. Vaccine-induced HIV-1-antigen-specific T cells in peripheral blood (macaques), liver, spleen, and intestinal and genital mucosa (mice) were characterized by intracellular cytokine staining. Vaccine-specific IgG antibodies (macaques) were detected using ELISA. In macaques, only the heterologous prime-boost regimens induced polyfunctional, persistent and balanced CD4+ and CD8+ T-cell responses specific to each HIV-1 vaccine antigen. AdC7-GRN priming increased the polyfunctionality of F4/AS01-induced CD4+ T cells. Approximately 50% of AdC7-GRN-induced memory CD8+ T cells exhibited an effector-memory phenotype. HIV-1-specific antibodies were detected with each regimen. In mice, antigen-specific CD4+ and CD8+ T-cell responses were detected in the mucosal and systemic anatomical compartments assessed. When administered in heterologous prime-boost regimens, AdC7-GRN and F4/AS01 candidate vaccines acted complementarily in inducing potent and persistent peripheral blood HIV-1-specific CD4+ and CD8+ T-cell responses and antibodies in macaques. Besides, adenoviral vector priming modulated the cytokine-expression profile of the protein-induced CD4+ T cells. Each regimen induced HIV-1-specific T-cell responses in systemic/local tissues in mice. This suggests that prime-boost regimens combining adjuvanted protein and low-seroprevalent chimpanzee adenoviral vectors represent an attractive vaccination strategy for clinical evaluation. PMID:25856308
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weber, Jonah M.; Chin, Michael
2002-04-30
The Control System for the Advanced Light Source (ALS) at Lawrence Berkeley National Lab (LBNL) uses in-house designed IndustryPack(registered trademark) (IP) modules contained in compact PCI (cPCI) crates with 16-bit analog I/O to control instrumentation. To make the IP modules interchangeable, each module is calibrated for gain and offset compensation. We initially developed a method of verifying and calibrating the IP modules in a lab bench test environment using a PC with LabVIEW. The subsequent discovery that the ADCs have significant drift characteristics over periods of days of installed operation prompted development of an ''in-situ'' calibration process--one in which themore » IP modules can be calibrated without removing them from the cPCI crates in the storage ring. This paper discusses the original LabVIEW PC calibration and the migration to the proposed in-situ EPICS control system calibration.« less
Heursen, Eva-Marie; Zuazo Ojeda, Amaya; Benavente Fernández, Isabel; Jimenez Gómez, Gema; Campuzano Fernández-Colima, Rosalía; Paz-Expósito, José; Lubián López, Simón Pedro
2017-01-01
Apparent diffusion coefficient (ADC) quantification has been proven to be of prognostic value in term newborns with hypoxic-ischaemic encephalopathy (HIE) who were treated under normothermia. To evaluate the prognostic value of ADC in standardized brain regions in neonates with HIE who were treated with therapeutic hypothermia (TH). This prospective cohort study included 54 term newborns who were admitted with HIE and treated with TH. All magnetic resonance imaging examinations were performed between days 4 and 6 of life, and ADC values were measured in 13 standardized regions of the brain. At 2 years of age we explored whether ADC values were related to composite outcomes (death or survival with abnormal neurodevelopment). The severity of HIE is inversely related to ADC values in different brain regions. We found that lower ADC values in the posterior limb of the internal capsule (PLIC), the thalami, the semioval centre, and frontal and parietal white matter were related to adverse outcomes. ADC values in the PLIC and thalami are good predictors of adverse outcomes (AUC 0.86 and 0.76). Low ADC values in the PLIC, thalamus, semioval centre, and frontal and parietal white matter in full-term infants with HIE treated with TH were associated with a poor outcome. © 2017 S. Karger AG, Basel.
The design of preamplifier and ADC circuit base on weak e-optical signal
NASA Astrophysics Data System (ADS)
Fen, Leng; Ying-ping, Yang; Ya-nan, Yu; Xiao-ying, Xu
2011-02-01
Combined with the demand of the process of weak e-optical signal in QPD detection system, the article introduced the circuit principle of deigning preamplifier and ADC circuit with I/V conversion, instrumentation amplifier, low-pass filter and 16-bit A/D transformation. At the same time the article discussed the circuit's noise suppression and isolation according to the characteristics of the weak signal, and gave the method of software rectification. Finally, tested the weak signal with keithley2000, and got a good effect.
Kotovich, D; Guedalia, J S B; Hoffmann, C; Sze, G; Eisenkraft, A; Yaniv, G
2017-07-01
Cytomegalovirus is the leading intrauterine infection. Fetal MR imaging is an accepted tool for fetal brain evaluation, yet it still lacks the ability to accurately predict the extent of the neurodevelopmental impairment, especially in fetal MR imaging scans with unremarkable findings. Our hypothesis was that intrauterine cytomegalovirus infection causes diffusional changes in fetal brains and that those changes may correlate with the severity of neurodevelopmental deficiencies. A retrospective analysis was performed on 90 fetal MR imaging scans of cytomegalovirus-infected fetuses with unremarkable results and compared with a matched gestational age control group of 68 fetal head MR imaging scans. ADC values were measured and averaged in the frontal, parietal, occipital, and temporal lobes; basal ganglia; thalamus; and pons. For neurocognitive assessment, the Vineland Adaptive Behavior Scales, Second Edition (VABS-II) was used on 58 children in the cytomegalovirus-infected group. ADC values were reduced for the cytomegalovirus-infected fetuses in most brain areas studied. The VABS-II showed no trend for the major domains or the composite score of the VABS-II for the cytomegalovirus-infected children compared with the healthy population distribution. Some subdomains showed an association between ADC values and VABS-II scores. Cytomegalovirus infection causes diffuse reduction in ADC values in the fetal brain even in unremarkable fetal MR imaging scans. Cytomegalovirus-infected children with unremarkable fetal MR imaging scans do not deviate from the healthy population in the VABS-II neurocognitive assessment. ADC values were not correlated with VABS-II scores. However, the lack of clinical findings, as seen in most cytomegalovirus-infected fetuses, does not eliminate the possibility of future neurodevelopmental pathology. © 2017 by American Journal of Neuroradiology.
Carrero-González, L; Kaulisch, T; Ruiz-Cabello, J; Pérez-Sánchez, J M; Peces-Barba, G; Stiller, D; Rodríguez, I
2012-09-01
The apparent diffusion coefficient (ADC) of hyperpolarized (HP) gases is a parameter that reflects changes in lung microstructure. However, ADC is dependent on many physiological and experimental variables that need to be controlled or specified in order to ensure the reliability and reproducibility of this parameter. A single breath-hold experiment is desirable in order to reduce the amount of consumed HP gas. The application of a positive end-expiratory pressure (PEEP) causes an increase in the residual gas volume. Depending on the applied PEEP, the ratio between the incoming and residual gas volumes will change and the ADC will vary, as long as both gases do not have the same diffusion coefficient. The most standard method for human applications uses air for breathing and a bolus of pure HP (3)He for MRI data acquisition. By applying this method in rats, we have demonstrated that ADC values are strongly dependent on the applied PEEP, and therefore on the residual gas volume in the lung. This outcome will play an important role in studies concerning certain diseases, such as emphysema, which is characterized by an increase in the residual volume. Ventilation with an oxygen-helium mixture (VOHeM) is a proposed single breath-hold method that uses two different gas mixtures (O(2)-(4)He for ventilation and HP (3)He-N(2) for imaging). The concentration of each gas in its respective mixture was calculated in order to obtain the same diffusion coefficient in both mixtures. ADCs obtained from VOHeM are independent of PEEP, thus minimizing the effect of the different residual volumes. Copyright © 2012 John Wiley & Sons, Ltd.
Parsian, Sana; Giannakopoulos, Nadia V.; Rahbar, Habib; Rendi, Mara H.; Chai, Xiaoyu
2016-01-01
OBJECTIVE To determine the underlying histopathologic features influencing apparent diffusion coefficient (ADC) values of breast fibroadenomas. MATERIALS AND METHODS Biopsy proven fibroadenomas (n=26) initially identified as suspicious on breast MRI were retrospectively evaluated. Histopathological assessments of lesion cellularity and stromal type were compared with ADC measures on diffusion-weighted MRI. RESULTS Presence of epithelial hyperplasia (increased cellularity) and dense collagenous stroma were both significantly associated with lower lesion ADC values (p=0.02 and 0.004, respectively. CONCLUSION Variations in epithelial cellularity and stromal type influence breast lesion ADC values and may explain the wide range of ADC measures observed in benign fibroadenomas. PMID:27379441
de Veth, M J; Artegoitia, V M; Campagna, S R; Lapierre, H; Harte, F; Girard, C L
2016-12-01
The metabolites of choline have a central role in many mammalian biological processes, and choline supplementation to the periparturient dairy cow improves hepatic lipid metabolism. However, variability in responses to choline supplementation has highlighted a lack of understanding of choline absorption in the lactating dairy cow. Our objective was to determine net choline absorption by measuring net portal fluxes of choline and choline metabolites in cows receiving either dietary supplements of rumen-protected choline (RPC) or abomasal delivery of choline (ADC). We also evaluated markers for choline bioavailability by examining relationships between net portal absorption of choline and choline metabolites in plasma and milk. Five late-lactation Holstein cows were used in a 5×5 Latin square design, with 5-d treatment periods and a 2-d interval between periods. Treatments were (1) control (0g/d of choline), (2) 12.5g/d of choline fed as RPC, (3) 25g/d of choline fed as RPC, (4) 12.5g/d of choline provided as ADC, and (5) 25g/d of choline provided as ADC. At the end of each 5-d period, milk was sampled and 9 blood samples were collected simultaneously from an artery and portal vein at 30-min intervals. Plasma, milk, and feed ingredient concentrations of acetylcholine, betaine, free choline, glycerophosphocholine, lysophosphatidylcholine, phosphatidylcholine, phosphocholine, and sphingomyelin were quantified by hydrophilic interaction liquid chromatography-tandem mass spectrometry. With an increasing dose of ADC, the net portal flux of free choline increased and regression analysis indicated 61% net absorption of the infused dose. Among the choline metabolites, only concentrations of betaine, free choline, and phosphocholine increased in both arterial plasma (3.9, 1.9, and 0.4 times, respectively) and milk (2.5, 1.4, and 1.0 times, respectively) with 25g/d of ADC relative to the control. For RPC, the net portal flux of free choline was low relative to ADC (13%), which was similar to the relative difference observed in the concentrations and yields of milk free choline and betaine (averaged 21%). When evaluating markers for choline bioavailability, betaine was the leading candidate. Betaine in plasma and milk (alone or in combination with phosphocholine) was strongly associated with net free choline portal flux (coefficient of determination ranging from 0.64 to 0.79). In summary, free choline supply to the lactating dairy cow increases only specific choline metabolites in plasma and milk, which can be potential markers for choline bioavailability. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Image quality stability of whole-body diffusion weighted imaging.
Chen, Yun-bin; Hu, Chun-miao; Zhong, Jing; Sun, Fei
2009-06-01
To assess the reproducibility of whole-body diffusion weighted imaging (WB-DWI) technique in healthy volunteers under normal breathing with background body signal suppression. WB-DWI was performed on 32 healthy volunteers twice within two-week period using short TI inversion-recovery diffusion-weighted echo-planar imaging sequence and built-in body coil. The volunteers were scanned across six stations continuously covering the entire body from the head to the feet under normal breathing. The bone apparent diffusion coefficient (ADC) and exponential ADC (eADC) of regions of interest (ROIs) were measured. We analyzed correlation of the results using paired-t-test to assess the reproducibility of the WB-DWI technique. We were successful in collecting and analyzing data of 64 WB-DWI images. There was no significant difference in bone ADC and eADC of 824 ROIs between the paired observers and paired scans (P>0.05). Most of the images from all stations were of diagnostic quality. The measurements of bone ADC and eADC have good reproducibility. WB-DWI technique under normal breathing with background body signal suppression is adequate.
Glaser, Nicole; Ngo, Catherine; Anderson, Steven; Yuen, Natalie; Trifu, Alexandra; O'Donnell, Martha
2012-07-01
Diabetic ketoacidosis (DKA) may cause brain injuries in children. The mechanisms responsible are difficult to elucidate because DKA involves multiple metabolic derangements. We aimed to determine the independent effects of hyperglycemia and ketosis on cerebral metabolism, blood flow, and water distribution. We used magnetic resonance spectroscopy to measure ratios of cerebral metabolites (ATP to inorganic phosphate [Pi], phosphocreatine [PCr] to Pi, N-acetyl aspartate [NAA] to creatine [Cr], and lactate to Cr) and diffusion-weighted imaging and perfusion-weighted imaging to assess cerebral water distribution (apparent diffusion coefficient [ADC] values) and cerebral blood flow (CBF) in three groups of juvenile rats (hyperglycemic, ketotic, and normal control). ATP-to-Pi ratio was reduced in both hyperglycemic and ketotic rats in comparison with controls. PCr-to-Pi ratio was reduced in the ketotic group, and there was a trend toward reduction in the hyperglycemic group. No significant differences were observed in NAA-to-Cr or lactate-to-Cr ratio. Cortical ADC was reduced in both groups (indicating brain cell swelling). Cortical CBF was also reduced in both groups. We conclude that both hyperglycemia and ketosis independently cause reductions in cerebral high-energy phosphates, CBF, and cortical ADC values. These effects may play a role in the pathophysiology of DKA-related brain injury.
A readout integrated circuit based on DBI-CTIA and cyclic ADC for MEMS-array-based focal plane
NASA Astrophysics Data System (ADS)
Miao, Liu; Dong, Wu; Zheyao, Wang
2016-11-01
A readout integrated circuit (ROIC) for a MEMS (microelectromechanical system)-array-based focal plane (MAFP) intended for imaging applications is presented. The ROIC incorporates current sources for diode detectors, scanners, timing sequence controllers, differential buffered injection-capacitive trans-impedance amplifier (DBI-CTIA) and 10-bit cyclic ADCs, and is integrated with MAFP using 3-D integration technology. A small-signal equivalent model is built to include thermal detectors into circuit simulations. The biasing current is optimized in terms of signal-to-noise ratio and power consumption. Layout design is tailored to fulfill the requirements of 3-D integration and to adapt to the size of MAFP elements, with not all but only the 2 bottom metal layers to complete nearly all the interconnections in DBI-CTIA and ADC in a 40 μm wide column. Experimental chips are designed and fabricated in a 0.35 μm CMOS mixed signal process, and verified in a code density test of which the results indicate a (0.29/-0.31) LSB differential nonlinearity (DNL) and a (0.61/-0.45) LSB integral nonlinearity (INL). Spectrum analysis shows that the effective number of bits (ENOB) is 9.09. The ROIC consumes 248 mW of power at most if not to cut off quiescent current paths when not needed. Project supported by by National Natural Science Foundation of China (No. 61271130), the Beijing Municipal Science and Tech Project (No. D13110100290000), the Tsinghua University Initiative Scientific Research Program (No. 20131089225), and the Shenzhen Science and Technology Development Fund (No. CXZZ20130322170740736).
Assessment of the Focal Hepatic Lesions Using Diffusion Tensor Magnetic Resonance Imaging
Oussous, Siham Ait; Boujraf, Saïd; Kamaoui, Imane
2016-01-01
The goal is assessing the diffusion magnetic resonance imaging (dMRI) method efficiency in characterizing focal hepatic lesions (FHLs). About 28-FHL patients were studied in Radiology and Clinical Imaging Department of our University Hospital using 1.5 Tesla MRI system between January 2010 and June 2011. Patients underwent hepatic MRI consisting of dynamic T1- and T2-weighted imaging. The dMRI was performed with b-values of 200 s/mm2 and 600 s/mm2. About 42 lesions measuring more than 1 cm were studied including the variation of the signal according to the b-value and the apparent diffusion coefficient (ADC). The diagnostic imaging reference was based on standard MRI techniques data for typical lesions and on histology after surgical biopsy for atypical lesions. About 38 lesions were assessed including 13 benign lesions consisting of 1 focal nodular hyperplasia, 8 angiomas, and 4 cysts. About 25 malignant lesions included 11 hepatocellular carcinoma, 9 hepatic metastases, 1 cholangiocarcinoma, and 4 lymphomas. dMRI of soft lesions demonstrated higher ADC of 2.26 ± 0.75 mm2/s, whereas solid lesions showed lower ADC 1.19 ± 0.33 mm2/s with significant difference (P = 0.05). Discrete values collections were noticed. These results were correlated to standard MRI and histological findings. Sensitivity of 93% and specificity of 84% were found in diagnoses of malignant tumors with an ADC threshold of 1.6 × 10−3 mm2/s. dMRI is important characterization method of FHL. However, it should not be used as single criteria of hepatic lesions malignity. MRI, clinical, and biological data must be correlated. Significant difference was found between benign and solid malignant lesions without threshold ADC values. Hence, it is difficult to confirm ADC threshold differentiating the lesion classification. PMID:27186537
Current Status of the Beam Position Monitoring System at TLS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuo, C. H.; Hu, K. H.; Chen, Jenny
2006-11-20
The beam position monitoring system is an important part of a synchrotron light source that supports its routine operation and studies of beam physics. The Taiwan light source is equipped with 59 BPMs. Highly precise closed orbits are measured by multiplexing BPMs. Data are acquired using multi-channel 16-bit ADC modules. Orbit data are sampled every millisecond. Fast orbit data are shared in a reflective memory network to support fast orbit feedback. Averaged data were updated to control database at a rate of 10 Hz. A few new generation digital BPMs were tested to evaluate their performance and functionality. This reportmore » summarizes the system structure, the software environment and the preliminary beam test of the BPM system.« less
Current Status of the Beam Position Monitoring System at TLS
NASA Astrophysics Data System (ADS)
Kuo, C. H.; Hu, K. H.; Chen, Jenny; Lee, Demi; Wang, C. J.; Hsu, S. Y.; Hsu, K. T.
2006-11-01
The beam position monitoring system is an important part of a synchrotron light source that supports its routine operation and studies of beam physics. The Taiwan light source is equipped with 59 BPMs. Highly precise closed orbits are measured by multiplexing BPMs. Data are acquired using multi-channel 16-bit ADC modules. Orbit data are sampled every millisecond. Fast orbit data are shared in a reflective memory network to support fast orbit feedback. Averaged data were updated to control database at a rate of 10 Hz. A few new generation digital BPMs were tested to evaluate their performance and functionality. This report summarizes the system structure, the software environment and the preliminary beam test of the BPM system.
Hoffmann, Karl-Titus; Garnov, Nikita; Vörkel, Cathrin; Kohlhof-Meinecke, Patricia; Ganslandt, Oliver; Bäzner, Hansjörg; Gihr, Georg Alexander; Kalman, Marcell; Henkes, Elina; Henkes, Hans; Schob, Stefan
2018-01-01
Background Morphologically similar appearing ring enhancing lesions in the brain parenchyma can be caused by a number of distinct pathologies, however, they consistently represent life-threatening conditions. The two most frequently encountered diseases manifesting as such are glioblastoma multiforme (GBM) and brain abscess (BA), each requiring disparate therapeutical approaches. As a result of their morphological resemblance, essential treatment might be significantly delayed or even ommited, in case results of conventional imaging remain inconclusive. Therefore, our study aimed to investigate, whether ADC histogram profiling reliably can distinguish between both entities, thus enhancing the differential diagnostic process and preventing treatment failure in this highly critical context. Methods 103 patients (51 BA, 52 GBM) with histopathologically confirmed diagnosis were enrolled. Pretreatment diffusion weighted imaging (DWI) was obtained in a 1.5T system using b values of 0, 500, and 1000 s/mm2. Whole lesion ADC volumes were analyzed using a histogram-based approach. Statistical analysis was performed using SPSS version 23. Results All investigated parameters were statistically different in comparison of both groups. Most importantly, ADCp10 was able to differentiate reliably between BA and GBM with excellent accuracy (0.948) using a cutpoint value of 70 × 10−5 mm2 × s−1. Conclusions ADC whole lesion histogram profiling provides a valuable tool to differentiate between morphologically indistinguishable mass lesions. Among the investigated parameters, the 10th percentile of the ADC volume distinguished best between GBM and BA. PMID:29719596
Ozturk, T; Bozgeyik, Z; Ozturk, F; Burakgazi, G; Akyol, M; Coskun, S; Ozkan, Y; Ogur, E
2015-08-01
The aim of this study was to evaluate the usefulness of diffusion-weighted magnetic resonance imaging (DWMRI) for differentation between Graves' disease and Hashimoto's thyroiditis. Fifty patients (27 Graves diseases and 23 Hashimoto thyroiditis) and twenty healthy volunteers were examined using T1, T2 and DWMRI. The patients were diagnosed on the basis of physical findings and the results of thyroid function tests and serological tests. Circular ROIs were positioned on the bilateral thyroid lobes and isthmus. All measurements were repeated three different b values including 100, 600 and 1000 s/mm2 in all cases. ADC (Apparent diffusion coefficient) maps were calculated automatically with the MR system. Mean ADC values were 2.93 × 10-3, 1.97 × 10-3 and 1.62 × 10-3 mm2/s in the healthy volunteers; 3.47 × 10-3, 2.25 × 10-3 and 1.64 × 10-3 mm2/s in Graves' disease; 2.53 × 10-3, 1.76 × 10-3, 1.28 × 10-3 mm2/s in Hashimoto thyroiditis for b100, b600 and b1000, respectively. The ADC values of the Graves diseases were higher than healty volunteers and Hashimoto thyroiditis. ADC values were statistically significant for differentation between Hashimoto thyroiditis and Graves' disease all b values (p < 0.05). DWMRI is fast sequence and does not require contrast agent. Quantitative assessment of the lesion is possible using ADC map. So, DWMRI may be useful differentiation of the Hashimoto thyroiditis and Graves' disease.
Nejadmoghaddam, Mohammad-Reza; Zarnani, Amir-Hassan; Ghahremanzadeh, Ramin; Ghods, Roya; Mahmoudian, Jafar; Yousefi, Maryam; Nazari, Mahboobeh; Ghahremani, Mohammad Hossein; Abolhasani, Maryam; Anissian, Ali; Mahmoudi, Morteza; Dinarvand, Rassoul
2017-10-17
Our recent findings strongly support the idea of PLAC1 being as a potential immunotherapeutic target in prostate cancer (PCa). Here, we have generated and evaluated an anti-placenta-specific1 (PLAC1)-based antibody drug conjugate (ADC) for targeted immunotherapy of PCa. Prostate cancer cells express considerable levels of PLAC1. The Anti-PLAC1 clone, 2H12C12, showed high reactivity with recombinant PLAC1 and selectivity recognized PLAC1 in prostate cancer cells but not in LS180 cells, the negative control. PLAC1 binding induced rapid internalization of the antibody within a few minutes which reached to about 50% after 15 min and almost completed within an hour. After SN38 conjugation to antibody, a drug-antibody ratio (DAR) of about 5.5 was achieved without apparent negative effect on antibody affinity to cell surface antigen. The ADC retained intrinsic antibody activity and showed enhanced and selective cytotoxicity with an IC50 of 62 nM which was about 15-fold lower compared to free drug. Anti-PLAC1-ADC induced apoptosis in human primary prostate cancer cells and prostate cell lines. No apparent cytotoxic effect was observed in in vivo animal safety experiments. Our newly developed anti-PLAC1-based ADCs might pave the way for a reliable, efficient, and novel immunotherapeutic modality for patients with PCa.
Murga, Jose D; Moorji, Sameer M; Han, Amy Q; Magargal, Wells W; DiPippo, Vincent A; Olson, William C
2015-02-15
Antibody-drug conjugates (ADCs) are an emerging class of cancer therapies that have demonstrated favorable activity both as single agents and as components of combination regimens. Phase 2 testing of an ADC targeting prostate-specific membrane antigen (PSMA) in advanced prostate cancer has shown antitumor activity. The present study examined PSMA ADC used in combination with potent antiandrogens (enzalutamide and abiraterone) and other compounds. Antiproliferative activity and expression of PSMA, prostate-specific antigen and androgen receptor were evaluated in the prostate cancer cell lines LNCaP and C4-2. Cells were tested for susceptibility to antiandrogens or other inhibitors, used alone and in combination with PSMA ADC. Potential drug synergy or antagonism was evaluated using the Bliss independence method. Enzalutamide and abiraterone demonstrated robust, statistically significant synergy when combined with PSMA ADC. Largely additive activity was observed between the antiandrogens and the individual components of the ADC (free drug and unmodified antibody). Rapamycin also synergized with PSMA ADC in certain settings. Synergy was linked in part to upregulation of PSMA expression. In androgen-dependent LNCaP cells, enzalutamide and abiraterone each inhibited proliferation, upregulated PSMA expression, and synergized with PSMA ADC. In androgen-independent C4-2 cells, enzalutamide and abiraterone showed no measurable antiproliferative activity on their own but increased PSMA expression and synergized with PSMA ADC nonetheless. PSMA expression increased progressively over 3 weeks with enzalutamide and returned to baseline levels 1 week after enzalutamide removal. The findings support exploration of clinical treatment regimens that combine potent antiandrogens and PSMA-targeted therapies for prostate cancer. © 2014 Wiley Periodicals, Inc.
Balci, N Cem; Momtahen, Amir Javad; Akduman, E Isin; Alkaade, Samer; Bilgin, Mehmet; Burton, Frank R
2008-10-01
To evaluate the correlation between apparent diffusion coefficient (ADC) values of the pancreas on diffusion-weighted imaging (DWI) and pancreatic exocrine function determined by HCO(3) concentration in the secretin endoscopic pancreatic function test (ePFT). Mean ADC values derived from 10 different points of the pancreatic gland on DWI were reviewed in 14 patients with normal (peak HCO(3) > or = 80 mEq/L) and 14 patients with abnormal (peak HCO(3) < 80 mEq/L) ePFT results. Magnetic resonance cholangiopancreatography (MRCP) images of the same patients were evaluated for the diagnosis of chronic pancreatitis. Correlation between ADC values and HCO(3) concentration as well as Cambridge scores in MRCP was performed using Spearman's correlation test. Mean ADC value of the pancreas was 1.52 +/- 0.13 x 10(-3) mm(2)/s in patients with abnormal ePFT results and 1.78 +/- 0.07 x 10(-3) mm(2)/s in the normal group. There was a significant statistical difference between the ADC values of the pancreas in the two groups (P < .0001). There was also a statistically significant correlation between HCO(3) level and ADC value of the pancreas in the study patients (r = 0.771, P < .0001). Morphologic changes of the pancreas according to the Cambridge classification were also well correlated with the mean ADC values (r = -0.763, P < .0001). Strong correlation between ADC value and pancreatic exocrine function as well as Cambridge score for chronic pancreatitis exists. Further studies are needed to determine the cut off ADC value for chronic pancreatitis.
Rajasekaran, S; Aiyer, Siddharth N; Shetty, Ajoy Prasad; Kanna, Rishi Mugesh; Maheswaran, Anupama; Shetty, Janardhan Yerram
2016-06-01
To evaluate the effectiveness of Riluzole as a pharmacotherapeutic treatment option for early cervical myelopathy using clinical parameters and DTI analysis. Early cervical myelopathy cases with MJOA scores ≥13, were recruited for the double-blinded, placebo-controlled randomised control trial. Thirty cases with fifteen cases each in the test and placebo group were studied. Analysis was done using diffusion tensor imaging (DTI) and clinical evaluation, pre- and post-institution of sodium channel blocker Riluzole for a period of 1 month (50 mg twice daily). Placebo group was treated with Vitamin B complex tablets. Diffusion co-efficient fractional anisotrophy (FA), apparent diffusion co-efficient (ADC), volume ratio (VR), relative anisotrophy (RA) and Eigen vectors were calculated. Outcomes analysis was based on clinical scores of MJOA, Nurick grading, SF-12, NDI, and statistical analysis of DTI datametrics. The mean MJOA score was 15.6 (13-17) with no significant change in the test and control groups. The mean ADC, FA values were 1533.36 (1238-1779) and 494.36 (364-628) and changed to 1531.57 (1312-2091) and 484.86 (294-597), respectively, in the Riluzole group. However, the changes in the values of ADC, FA, and other co-efficients including VR, RA and eigenvectors in the two groups were not statistically significant. The functional scores in the SF-12 and NDI questionnaires did not change significantly. Our study did not show a significant change in the clinical outcome and DTI Indices with the use of Riluzole as a standalone pharmacotherapeutic agent for early cervical myelopathy. More studies may be needed to confirm the usefulness of Riluzole as a treatment option for cervical myelopathy.
Diffusion tensor imaging of the sural nerve in normal controls☆
Kim, Boklye; Srinivasan, Ashok; Sabb, Brian; Feldman, Eva L; Pop-Busui, Rodica
2016-01-01
Objective To develop a diffusion tensor imaging (DTI) protocol for assessing the sural nerve in healthy subjects. Methods Sural nerves in 25 controls were imaged using DTI at 3 T with 6, 15, and 32 gradient directions. Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) were computed from nerve regions of interest co-registered with T2-weighted images. Results Coronal images with 0.5(RL)×2.0(FH)×0.5(AP) mm3 resolution successfully localized the sural nerve. FA maps showed less variability with 32 directions (0.559±0.071) compared to 15(0.590±0.080) and 6(0.659±0.109). Conclusions Our DTI protocol was effective in imaging sural nerves in controls to establish normative FA/ADC, with potential to be used non-invasively in diseased nerves of patients. PMID:24908367
Malkyarenko, Dariya I; Chenevert, Thomas L
2014-12-01
To describe an efficient procedure to empirically characterize gradient nonlinearity and correct for the corresponding apparent diffusion coefficient (ADC) bias on a clinical magnetic resonance imaging (MRI) scanner. Spatial nonlinearity scalars for individual gradient coils along superior and right directions were estimated via diffusion measurements of an isotropicic e-water phantom. Digital nonlinearity model from an independent scanner, described in the literature, was rescaled by system-specific scalars to approximate 3D bias correction maps. Correction efficacy was assessed by comparison to unbiased ADC values measured at isocenter. Empirically estimated nonlinearity scalars were confirmed by geometric distortion measurements of a regular grid phantom. The applied nonlinearity correction for arbitrarily oriented diffusion gradients reduced ADC bias from 20% down to 2% at clinically relevant offsets both for isotropic and anisotropic media. Identical performance was achieved using either corrected diffusion-weighted imaging (DWI) intensities or corrected b-values for each direction in brain and ice-water. Direction-average trace image correction was adequate only for isotropic medium. Empiric scalar adjustment of an independent gradient nonlinearity model adequately described DWI bias for a clinical scanner. Observed efficiency of implemented ADC bias correction quantitatively agreed with previous theoretical predictions and numerical simulations. The described procedure provides an independent benchmark for nonlinearity bias correction of clinical MRI scanners.
NASA Astrophysics Data System (ADS)
Jiango, Homin; Liuo, Howard; Guzzino, Kim
2016-07-01
In this study, the design of a 4 bit, 10-gigasamples-per-second analog-to-digital converter (ADC) printed circuit board assembly (PCBA) was revised, manufactured, and tested. It is used for digitizing radio telescopes. An Adsantec ANST7120-KMA flash ADC chip was used, as in the original design. Associated with the field-programmable gate array platform developed by the Collaboration for Astronomy Signal Processing and Electronics Research community, the developed PCBA provides data acquisition systems with a wider bandwidth and simplifies the intermediate frequency section. The current version of the PCBA exhibits an analog bandwidth of up to 10 GHz (3 dB loss), and the chip exhibits an analog bandwidth of up to 18 GHz. This facilitates second and third Nyquist sampling. The following worstcase performance parameters were obtained from the revised PCBA at over 5 GHz: spurious-free dynamic range of 12 dB, signal-to-noise and distortion ratio of 2 dB, and effective number of bits of 0.7. The design bugs in the ADC chip caused the poor performance. The vendor created a new batch run and confirmed that the ADC chips of the new batch will meet the specifications addressed in its data sheet.
An all-silica three element wide-field corrector for GMT
NASA Astrophysics Data System (ADS)
Saunders, Will; Gillingham, Peter; Lin, Sean; Woodruff, Bob; Rakich, Andrew
2016-08-01
We present an alternative Corrector-ADC design for GMT. The design consists of just 3 silica lenses, of maximum size 1.51m, and includes only a single low-precision asphere for 20' field-of-view, and none for 10'. The polychromatic (360nm-1300nm) image quality is d80<0.043" at zenith and d80<0.20" for ZD<60 degrees. The monochromatic image quality is d80<0.1" everywhere, and typically 0.05". The ADC action is achieved by tilt and translation of all three lenses; L1 and L2 via simple slide mechanisms each using a single encoded actuator, and L3 via a novel `tracker-ball' support and three actuators. There is also a small motion of M2 via the hexapod, automatically generated by the AGWS system. The ADC action causes a small non-telecentricity, but this is much less than the unavoidable chromatic effects shared with the baseline design. The ADC action also changes the distortion pattern of the telescope, but this can be used positively, to reduce the maximum image motion due to differential refraction by a factor of three. The transmission is superb at all wavelengths, because of the reduced number of air/glass surfaces, and the use only of fused silica.
Jelescu, Ileana Ozana; Ciobanu, Luisa; Geffroy, Françoise; Marquet, Pierre; Le Bihan, Denis
2014-03-01
There is evidence that physiological or pathological cell swelling is associated with a decrease of the apparent diffusion coefficient (ADC) of water in tissues, as measured with MRI. However the mechanism remains unclear. Magnetic resonance microscopy, performed on small tissue samples, has the potential to distinguish effects occurring at cellular and tissue levels. A three-dimensional diffusion prepared fast imaging with steady-state free precession sequence for MR microscopy was implemented on a 17.2 T imaging system and used to investigate the effect of two biological challenges known to cause cell swelling, exposure to a hypotonic solution or to ouabain, on Aplysia nervous tissue. The ADC was measured inside isolated neuronal soma and in the region of cell bodies of the buccal ganglia. Both challenges resulted in an ADC increase inside isolated neuronal soma (+31 ± 24% and +30 ± 11%, respectively) and an ADC decrease at tissue level in the buccal ganglia (-12 ± 5% and -18 ± 8%, respectively). A scenario involving a layer of water molecules bound to the inflating cell membrane surface is proposed to reconcile this apparent discrepancy. Copyright © 2014 John Wiley & Sons, Ltd.
Ni, Liangping; Liu, Ying
2018-04-01
The present study aimed to assess early-stage nasopharyngeal carcinoma (NPC) with dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and diffusion-weighted imaging (DWI) at 3.0 T. A total of 44 patients newly diagnosed with NPC were included in the present study. All patients underwent MR examination at 3.0 T using DCE-MRI and DWI. The volume transfer constant ( K trans ), flux rate constant between extravascular extracellular space and plasma ( K ep ), the volume of extravascular extracellular space per unit volume of tissue ( V e ) and the apparent diffusion coefficient (ADC) of tumours were investigated. Furthermore, the correlation between clinical stages and ADC value and K trans were analysed. The diagnostic accuracy of K trans and ADC were estimated using receiver operating characteristic curves. NPC stage correlated positively with K trans and negatively with ADC values. Additionally, tumour K trans negatively correlated with ADC value. The sensitivity and accuracy of combined K trans and ADC in distinguishing between stage II and stage III and stage III and IV were higher than the values of either measurement used separately. The present study suggested that K trans and ADC derived from DCE-MRI and DWI may be useful to detect stage early NPC accurately. K trans and ADC in combination were superior than either alone.
NASA Astrophysics Data System (ADS)
Cho, Jae-Hwan; Lee, Hae-Kag; Yang, Han-Joon; Lee, Gui-Won; Park, Yong-Soon; Chung, Woon-Kwan
2013-01-01
In this study, the authors investigated whether periodically-rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) diffusion-weighted imaging (DWI) can remove magnetic susceptibility artifacts and compared apparent diffusion coefficient (ADC) values for PROPELLER DWI and the common echo planar (EP) DWI. Twenty patients that underwent brain MRI with a metal dental implant were selected. A 3.0T MR scanner was then used to obtain EP DWI, PROPELLER DWI, and corresponding apparent diffusion coefficient (ADC) maps for a b-value of 0 and 1,000 s/mm2. The frequencies of magnetic susceptibility artifacts in four parts of the brain (bilateral temporal lobes, pons, and orbit) were selected. In the ADC maps, we measured the ADC values of both sides of the temporal lobe and the pons. According to the study results, the frequency of magnetic susceptibility artifacts in PROPELLER DW images was lower than it was in EP DW images. In ADC maps, the ADC values of the bilateral temporal lobes and the pons were all higher in PROPELLER ADC maps than in EP ADC maps. Our findings show that when a high-field MRI machine is used, magnetic susceptibility artifacts can distort anatomical structures and produce high-intensity signals. Furthermore, our findings suggest that in many cases, PROPELLER DWI would be helpful in terms of achieving a correct diagnosis.
Regional ADC values of the normal brain: differences due to age, gender, and laterality.
Naganawa, Shinji; Sato, Kimihide; Katagiri, Toshio; Mimura, Takeo; Ishigaki, Takeo
2003-01-01
The purpose of this study was to evaluate the stability of measurement for apparent diffusion coefficient (ADC) values in normal brain, to clarify the effect of aging on ADC values, to compare ADC values between men and women, and to compare ADC values between right and left sides of the brain. To evaluate the stability of measurements, five normal volunteers (four men and one woman) were examined five times on different days. Then, 294 subjects with normal MR imaging (147 men and 147 women; age range 20-89 years) were measured. The ADC measurement in normal volunteers was stable. The ADC values stayed within the 5% deviation of average values in all volunteers (mean+/-standard deviation 2.3+/-1.2%). The ADC values gradually increased by aging in all regions. In thalamus, no significant difference was seen between right and left in the subjects under 60 years; however, right side showed higher values in the subjects over 60 years (p<0.01). In the subjects under 60 years, women showed higher values in right frontal, bilateral thalamus, and temporal (p<0.01); however, in the subjects over 60 years, no region showed difference between men and women. The knowledge obtained in this study may be helpful to understand the developmental and aging mechanisms of normal brain and may be useful for the future quantitative study as a reference.
Recent Advances in Antibody-Drug Conjugates for Breast Cancer Treatment.
Deng, Shanshan; Lin, Zongtao; Li, Wei
2017-01-01
Breast cancer is the most common cancer in women, with roughly half a million deaths per year worldwide. Among various approaches for breast cancer treatment, chemotherapy is predominantly used for patients at stages II-IV, and monoclonal antibody (mAb) therapy is used for patients with human epidermal growth factor receptor 2 (HER2) overexpression. Integrating the tumor specificity provided by unique mAbs and cytotoxicity of small molecule drugs, antibody-drug conjugates (ADCs) are a series of smart chemotherapeutics that have recently shown great promise in treating a number of cancer types. ADCs are designed to selectively attack and kill cancer cells with minimal toxicity to normal tissues. Ado-Trastuzumab emtansine (T-DM1) was the first and only ADC approved by the US Food and Drug Administration for HER2-positive breast cancer. Following the success of T-DM1, many novel ADCs have been developed, and their anticancer efficacies are currently undergoing preclinical or clinical investigation. The development of ADCs is a rapidly progressing field, and this review aims to summarize the most recent advances in ADCs targeting breast cancer over the past five years (2011-2016). The review highlights compositions and mechanisms of action of these newly developed ADCs and discusses current challenges and future directions of developing new ADCs for improved treatment of breast cancer. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Newitt, David C; Malyarenko, Dariya; Chenevert, Thomas L; Quarles, C Chad; Bell, Laura; Fedorov, Andriy; Fennessy, Fiona; Jacobs, Michael A; Solaiyappan, Meiyappan; Hectors, Stefanie; Taouli, Bachir; Muzi, Mark; Kinahan, Paul E; Schmainda, Kathleen M; Prah, Melissa A; Taber, Erin N; Kroenke, Christopher; Huang, Wei; Arlinghaus, Lori R; Yankeelov, Thomas E; Cao, Yue; Aryal, Madhava; Yen, Yi-Fen; Kalpathy-Cramer, Jayashree; Shukla-Dave, Amita; Fung, Maggie; Liang, Jiachao; Boss, Michael; Hylton, Nola
2018-01-01
Diffusion weighted MRI has become ubiquitous in many areas of medicine, including cancer diagnosis and treatment response monitoring. Reproducibility of diffusion metrics is essential for their acceptance as quantitative biomarkers in these areas. We examined the variability in the apparent diffusion coefficient (ADC) obtained from both postprocessing software implementations utilized by the NCI Quantitative Imaging Network and online scan time-generated ADC maps. Phantom and in vivo breast studies were evaluated for two ([Formula: see text]) and four ([Formula: see text]) [Formula: see text]-value diffusion metrics. Concordance of the majority of implementations was excellent for both phantom ADC measures and in vivo [Formula: see text], with relative biases [Formula: see text] ([Formula: see text]) and [Formula: see text] (phantom [Formula: see text]) but with higher deviations in ADC at the lowest phantom ADC values. In vivo [Formula: see text] concordance was good, with typical biases of [Formula: see text] to 3% but higher for online maps. Multiple b -value ADC implementations were separated into two groups determined by the fitting algorithm. Intergroup mean ADC differences ranged from negligible for phantom data to 2.8% for [Formula: see text] in vivo data. Some higher deviations were found for individual implementations and online parametric maps. Despite generally good concordance, implementation biases in ADC measures are sometimes significant and may be large enough to be of concern in multisite studies.
Regier, M; Derlin, T; Schwarz, D; Laqmani, A; Henes, F O; Groth, M; Buhk, J-H; Kooijman, H; Adam, G
2012-10-01
To investigate the potential correlation of the apparent diffusion coefficient assessed by diffusion-weighted MRI (DWI) and glucose metabolism determined by the standardized uptake value (SUV) at 18F-FDG PET/CT in non-small cell lung cancer (NSCLC). 18F-FDG PET/CT and DWI (TR/TE, 2000/66 ms; b-values, 0 and 500 s/mm(2)) were performed in 41 consecutive patients with histologically verified NSCLC. Analysing the PET-CT data calculation of the mean (SUV(mean)) and maximum (SUV(max)) SUV was performed. By placing a region-of-interest (ROI) encovering the entire tumor mean (ADC(mean)) and minimum ADC (ADC(min)) were determined by two independent radiologists. Results of 18F-FDG PET-CT and DWI were compared on a per-patient basis. For statistical analysis Pearson's correlation coefficient, Bland-Altman and regression analysis were assessed. Data analysis revealed a significant inverse correlation of the ADC(min) and SUV(max) (r=-0.46; p=0.032). Testing the correlation of the ADC(min) and SUV(max) for each histological subtype separately revealed that the inverse correlation was good for both adenocarcinomas (r=-0.47; p=0.03) and squamouscell carcinomas (r=-0.71; p=0.002), respectively. No significant correlation was found for the comparison of ADC(min) and SUV(mean) (r=-0.29; p=0.27), ADC(mean) vs. SUV(mean) (r=-0.28; p=0.31) or ADC(mean) vs. SUV(max) (r=-0.33; p=0.23). The κ-value of 0.88 indicated a good agreement between both observers. This preliminary study is the first to verify the relation between the SUV and the ADC in NSCLC. The significant inverse correlation of these two quantitative imaging approaches points out the association of metabolic activity and tumor cellularity. Therefore, DWI with ADC measurement might represent a new prognostic marker in NSCLC. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Design and development progress of a LLRF control system for a 500 MHz superconducting cavity
NASA Astrophysics Data System (ADS)
Lee, Y. S.; Kim, H. W.; Song, H. S.; Lee, J. H.; Park, K. H.; Yu, I. H.; Chai, J. S.
2012-07-01
The LLRF (low-level radio-frequency) control system which regulates the amplitude and the phase of the accelerating voltage inside a RF cavity is essential to ensure the stable operation of charged particle accelerators. Recent advances in digital signal processors and data acquisition systems have allowed the LLRF control system to be implemented in digitally and have made it possible to meet the higher demands associated with the performance of LLRF control systems, such as stability, accuracy, etc. For this reason, many accelerator laboratories have completed or are completing the developments of digital LLRF control systems. The digital LLRF control system has advantages related with flexibility and fast reconfiguration. This paper describes the design of the FPGA (field programmable gate array) based LLRF control system and the status of development for this system. The proposed LLRF control system includes an analog front-end, a digital board (ADC (analog to digital converter), DAC (digital to analog converter), FPGA, etc.) and a RF & clock generation system. The control algorithms will be implemented by using the VHDL (VHSIC (very high speed integrated circuits) hardware description language), and the EPICS (experiment physics and industrial control system) will be ported to the host computer for the communication. In addition, the purpose of this system is to control a 500 MHz RF cavity, so the system will be applied to the superconducting cavity to be installed in the PLS storage ring, and its performance will be tested.
Research about the high precision temperature measurement
NASA Astrophysics Data System (ADS)
Lin, J.; Yu, J.; Zhu, X.; Zeng, Z.; Deng, Y.
2012-12-01
High precision temperature control system is one of most important support conditions for tunable birefringent filter.As the first step,we researched some high precision temperature measurement methods for it. Firstly, circuits with a 24 bit ADC as the sensor's reader were carefully designed; Secondly, an ARM porcessor is used as the centrol processing unit, it provides sufficient reading and procesing ability; Thirdly, three kinds of sensors, PT100, Dale 01T1002-5 thermistor, Wheatstone bridge(constructed by pure copper and manganin) as the senor of the temperature were tested respectively. The resolution of the measurement with these three kinds of sensors are all better than 0.001 that's enough for 0.01 stability temperature control. Comparatively, Dale 01T1002-5 thermistor could get the most accurate temperature of the key point, Wheatstone bridge could get the most accurate mean temperature of the whole layer, both of them will be used in our futrue temperature controll system.
Farlow, Martin R; Grossberg, George T; Sadowsky, Carl H; Meng, Xiangyi; Somogyi, Monique
2013-01-01
Aims The 24-week, prospective, randomized, double-blind ACTION study investigated the efficacy, safety, and tolerability of 13.3 versus 4.6 mg/24 h rivastigmine patch in patients with severe Alzheimer's disease (AD). Methods Patients had probable AD and Mini–Mental State Examination scores ≥3–≤12. Primary outcome measures were as follows: Severe Impairment Battery (SIB) and AD Cooperative Study–Activities of Daily Living scale–Severe Impairment Version (ADCS-ADL-SIV). Secondary outcomes were as follows: ADCS-Clinical Global Impression of Change (ADCS-CGIC), 12-item Neuropsychiatric Inventory (NPI-12), and safety/tolerability. Results Of 1014 patients screened, 716 were randomized to 13.3 mg/24 h (N = 356) or 4.6 mg/24 h (N = 360) patch. Baseline characteristics/demographics were comparable. Completion rates were as follows: 64.3% (N = 229) with 13.3 mg/24 h and 65.0% (N = 234) with 4.6 mg/24 h patch. The 13.3 mg/24 h patch was significantly superior to 4.6 mg/24 h patch on cognition (SIB) and function (ADCS-ADL-SIV) at Week 16 (P < 0.0001 and P = 0.049, respectively) and 24 (primary endpoint; P < 0.0001 and P = 0.025). Significant between-group differences (Week 24) were observed on the ADCS-CGIC (P = 0.0023), not NPI-12 (P = 0.1437). A similar proportion of the 13.3 mg/24 h and 4.6 mg/24 h patch groups reported adverse events (AEs; 74.6% and 73.3%, respectively) and serious AEs (14.9% and 13.6%). Conclusions The 13.3 mg/24 h patch demonstrated superior efficacy to 4.6 mg/24 h patch on SIB and ADCS-ADL-SIV, without marked increase in AEs, suggesting higher-dose patch has a favorable benefit-to-risk profile in severe AD. PMID:23924050
Thörmer, Gregor; Otto, Josephin; Horn, Lars-Christian; Garnov, Nikita; Do, Minh; Franz, Toni; Stolzenburg, Jens-Uwe; Moche, Michael; Kahn, Thomas; Busse, Harald
2015-01-01
Clinical management of prostate cancer increasingly aims to distinguish aggressive types that require immediate and radical treatment from indolent tumors that are candidates for watchful waiting. This requires reliable and reproducible parameters to effectively control potential cancer progression. Magnetic resonance imaging (MRI) may provide a non-invasive means for this purpose. To assess the value of diffusion-weighted imaging and proton MR spectroscopy for the prediction of prostate cancer (PCa) aggressiveness. In 39 of 64 consecutive patients who underwent endorectal 3-T MRI prior to radical prostatectomy, prostate specimens were analyzed as whole-mount step sections. Apparent diffusion coefficient (ADC), normalized ADC (nADC: tumor/healthy tissue), choline/citrate (CC), and (choline + creatine)/citrate (CCC) ratios were correlated with Gleason scores (GS) from histopathological results. The power to discriminate low (GS ≤ 6) from higher-risk (GS ≥ 7) tumors was assessed with receiver operating characteristics (area under the curve [AUC]). Resulting threshold values were used by a blinded reader to distinguish between aggressive and indolent tumors. Ninety lesions (1 × GS = 5, 41 × GS = 6, 36 × GS = 7, 12 × GS = 8) were considered. nADC (AUC = 0.90) showed a higher discriminatory power than ADC (AUC = 0.79). AUC for CC and CCC were 0.73 and 0.82, respectively. Using either nADC < 0.46 or CCC > 1.3, as well as both criteria for aggressive PCa, the reader correctly identified aggressive and indolent tumors in 31 (79%), 28 (72%), and 33 of 39 patients (85%), respectively. Predictions of tumor aggressiveness from TRUS-guided biopsies were correct in 27 of 36 patients (75%). The combination of a highly sensitive normalized ADC with a highly specific CCC was found to be well suited to prospectively estimate PCa aggressiveness with a similar diagnostic accuracy as biopsy results. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Barbaro, Brunella; Vitale, Renata; Valentini, Vincenzo; Illuminati, Sonia; Vecchio, Fabio M; Rizzo, Gianluca; Gambacorta, Maria Antonietta; Coco, Claudio; Crucitti, Antonio; Persiani, Roberto; Sofo, Luigi; Bonomo, Lorenzo
2012-06-01
To prospectively monitor the response in patients with locally advanced nonmucinous rectal cancer after chemoradiotherapy (CRT) using diffusion-weighted magnetic resonance imaging. The histopathologic finding was the reference standard. The institutional review board approved the present study. A total of 62 patients (43 men and 19 women; mean age, 64 years; range, 28-83) provided informed consent. T(2)- and diffusion-weighted magnetic resonance imaging scans (b value, 0 and 1,000 mm(2)/s) were acquired before, during (mean 12 days), and 6-8 weeks after CRT. We compared the median apparent diffusion coefficients (ADCs) between responders and nonresponders and examined the associations with the Mandard tumor regression grade (TRG). The postoperative nodal status (ypN) was evaluated. The Mann-Whitney/Wilcoxon two-sample test was used to evaluate the relationships among the pretherapy ADCs, extramural vascular invasion, early percentage of increases in ADCs, and preoperative ADCs. Low pretreatment ADCs (<1.0 × 10(-3)mm(2)/s) were correlated with TRG 4 scores (p = .0011) and associated to extramural vascular invasion with ypN+ (85.7% positive predictive value for ypN+). During treatment, the mean percentage of increase in tumor ADC was significantly greater in the responders than in the nonresponders (p < .0001) and a >23% ADC increase had a 96.3% negative predictive value for TRG 4. In 9 of 16 complete responders, CRT-related tumor downsizing prevented ADC evaluations. The preoperative ADCs were significantly different (p = .0012) between the patients with and without downstaging (preoperative ADC ≥1.4 × 10(-3)mm(2)/s showed a positive and negative predictive value of 78.9% and 61.8%, respectively, for response assessment). The TRG 1 and TRG 2-4 groups were not significantly different. Diffusion-weighted magnetic resonance imaging seems to be a promising tool for monitoring the response to CRT. Copyright © 2012 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barbaro, Brunella, E-mail: bbarbaro@rm.unicatt.it; Vitale, Renata; Valentini, Vincenzo
2012-06-01
Purpose: To prospectively monitor the response in patients with locally advanced nonmucinous rectal cancer after chemoradiotherapy (CRT) using diffusion-weighted magnetic resonance imaging. The histopathologic finding was the reference standard. Methods and Materials: The institutional review board approved the present study. A total of 62 patients (43 men and 19 women; mean age, 64 years; range, 28-83) provided informed consent. T{sub 2}- and diffusion-weighted magnetic resonance imaging scans (b value, 0 and 1,000 mm{sup 2}/s) were acquired before, during (mean 12 days), and 6-8 weeks after CRT. We compared the median apparent diffusion coefficients (ADCs) between responders and nonresponders and examinedmore » the associations with the Mandard tumor regression grade (TRG). The postoperative nodal status (ypN) was evaluated. The Mann-Whitney/Wilcoxon two-sample test was used to evaluate the relationships among the pretherapy ADCs, extramural vascular invasion, early percentage of increases in ADCs, and preoperative ADCs. Results: Low pretreatment ADCs (<1.0 Multiplication-Sign 10{sup -3}mm{sup 2}/s) were correlated with TRG 4 scores (p = .0011) and associated to extramural vascular invasion with ypN+ (85.7% positive predictive value for ypN+). During treatment, the mean percentage of increase in tumor ADC was significantly greater in the responders than in the nonresponders (p < .0001) and a >23% ADC increase had a 96.3% negative predictive value for TRG 4. In 9 of 16 complete responders, CRT-related tumor downsizing prevented ADC evaluations. The preoperative ADCs were significantly different (p = .0012) between the patients with and without downstaging (preoperative ADC {>=}1.4 Multiplication-Sign 10{sup -3}mm{sup 2}/s showed a positive and negative predictive value of 78.9% and 61.8%, respectively, for response assessment). The TRG 1 and TRG 2-4 groups were not significantly different. Conclusion: Diffusion-weighted magnetic resonance imaging seems to be a promising tool for monitoring the response to CRT.« less
Anal Cancer Incidence in the United States, 1977–2011: Distinct Patterns by Histology and Behavior
Shiels, Meredith S.; Kreimer, Aimée R.; Coghill, Anna E.; Darragh, Teresa M.; Devesa, Susan S.
2015-01-01
Background Although anal squamous cell carcinoma (SCC) and adenocarcinoma (ADC) are generally combined in cancer surveillance, their etiologies likely differ. Here, we describe demographic characteristics and trends in incidence rates (IRs) of anal cancer by histology (SCC, ADC) and behavior (invasive, in situ) in the United States. Methods With data from the Surveillance, Epidemiology and End Results (SEER) Program, we estimated age-adjusted anal cancer IRs across behavior/histology by demographic and tumor characteristics for 2000–2011. Trends in IRs and annual percent changes during 1977–2011 were also estimated and compared to rectal cancer. Results Women had higher rates of SCC (rate ratio [RR]=1.45; 95%CI 1.40–1.50) and lower rates of ADC (RR=0.68; 95%CI 0.62–0.74) and squamous carcinoma in situ (CIS) (RR=0.36; 95%CI 0.34–0.38) than men. Blacks had lower rates of SCC (RR=0.82; 95%CI 0.77–0.87) and CIS (RR=0.90; 95%CI 0.83–0.98) than non-Hispanic whites, but higher rates of ADC (RR=1.48; 95%CI 1.29–1.70). Anal cancer IRs were higher in men and blacks aged <40 years. During 1992–2011, SCC IRs increased 2.9%/year, ADC IRs declined non-significantly, and CIS IRs rose 14.2%/year. SCC and ADC IR patterns and trends were similar across anal and rectal cancers. Conclusions Rates of anal SCC and CIS have increased strongly over time, in contrast to rates of anal ADC, similar to trends observed for rectal SCC and ADC. Impact Anal SCC and ADC likely have different etiologies, but may have similar etiologies to rectal SCC and ADC, respectively. Strong increases in CIS IRs over time may reflect anal cancer screening patterns. PMID:26224796
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ruberti, M.; Averbukh, V.; Decleva, P.
2014-10-28
We present the first implementation of the ab initio many-body Green's function method, algebraic diagrammatic construction (ADC), in the B-spline single-electron basis. B-spline versions of the first order [ADC(1)] and second order [ADC(2)] schemes for the polarization propagator are developed and applied to the ab initio calculation of static (photoionization cross-sections) and dynamic (high-order harmonic generation spectra) quantities. We show that the cross-section features that pose a challenge for the Gaussian basis calculations, such as Cooper minima and high-energy tails, are found to be reproduced by the B-spline ADC in a very good agreement with the experiment. We also presentmore » the first dynamic B-spline ADC results, showing that the effect of the Cooper minimum on the high-order harmonic generation spectrum of Ar is correctly predicted by the time-dependent ADC calculation in the B-spline basis. The present development paves the way for the application of the B-spline ADC to both energy- and time-resolved theoretical studies of many-electron phenomena in atoms, molecules, and clusters.« less
Lyu, Tao; Yao, Suying; Nie, Kaiming; Xu, Jiangtao
2014-11-17
A 12-bit high-speed column-parallel two-step single-slope (SS) analog-to-digital converter (ADC) for CMOS image sensors is proposed. The proposed ADC employs a single ramp voltage and multiple reference voltages, and the conversion is divided into coarse phase and fine phase to improve the conversion rate. An error calibration scheme is proposed to correct errors caused by offsets among the reference voltages. The digital-to-analog converter (DAC) used for the ramp generator is based on the split-capacitor array with an attenuation capacitor. Analysis of the DAC's linearity performance versus capacitor mismatch and parasitic capacitance is presented. A prototype 1024 × 32 Time Delay Integration (TDI) CMOS image sensor with the proposed ADC architecture has been fabricated in a standard 0.18 μm CMOS process. The proposed ADC has average power consumption of 128 μW and a conventional rate 6 times higher than the conventional SS ADC. A high-quality image, captured at the line rate of 15.5 k lines/s, shows that the proposed ADC is suitable for high-speed CMOS image sensors.
Fast and Analytical EAP Approximation from a 4th-Order Tensor.
Ghosh, Aurobrata; Deriche, Rachid
2012-01-01
Generalized diffusion tensor imaging (GDTI) was developed to model complex apparent diffusivity coefficient (ADC) using higher-order tensors (HOTs) and to overcome the inherent single-peak shortcoming of DTI. However, the geometry of a complex ADC profile does not correspond to the underlying structure of fibers. This tissue geometry can be inferred from the shape of the ensemble average propagator (EAP). Though interesting methods for estimating a positive ADC using 4th-order diffusion tensors were developed, GDTI in general was overtaken by other approaches, for example, the orientation distribution function (ODF), since it is considerably difficult to recuperate the EAP from a HOT model of the ADC in GDTI. In this paper, we present a novel closed-form approximation of the EAP using Hermite polynomials from a modified HOT model of the original GDTI-ADC. Since the solution is analytical, it is fast, differentiable, and the approximation converges well to the true EAP. This method also makes the effort of computing a positive ADC worthwhile, since now both the ADC and the EAP can be used and have closed forms. We demonstrate our approach with 4th-order tensors on synthetic data and in vivo human data.
Fast and Analytical EAP Approximation from a 4th-Order Tensor
Ghosh, Aurobrata; Deriche, Rachid
2012-01-01
Generalized diffusion tensor imaging (GDTI) was developed to model complex apparent diffusivity coefficient (ADC) using higher-order tensors (HOTs) and to overcome the inherent single-peak shortcoming of DTI. However, the geometry of a complex ADC profile does not correspond to the underlying structure of fibers. This tissue geometry can be inferred from the shape of the ensemble average propagator (EAP). Though interesting methods for estimating a positive ADC using 4th-order diffusion tensors were developed, GDTI in general was overtaken by other approaches, for example, the orientation distribution function (ODF), since it is considerably difficult to recuperate the EAP from a HOT model of the ADC in GDTI. In this paper, we present a novel closed-form approximation of the EAP using Hermite polynomials from a modified HOT model of the original GDTI-ADC. Since the solution is analytical, it is fast, differentiable, and the approximation converges well to the true EAP. This method also makes the effort of computing a positive ADC worthwhile, since now both the ADC and the EAP can be used and have closed forms. We demonstrate our approach with 4th-order tensors on synthetic data and in vivo human data. PMID:23365552
Kanmaz, Lutfi; Karavas, Erdal
2018-05-29
The purpose of this study was to evaluate the value of diffusion-weighted MRI (DW-MRI) in differentiating benign and malignant head and neck masses by comparing their apparent diffusion coefficient (ADC) values. The study included 32 patients with a neck mass >1 cm in diameter who were examined with echo planar DW-MRI. Two different diffusion gradients (b values of b = 0 and b = 1000 s/mm²) were applied. DWI and ADC maps of 32 neck masses in 32 patients were obtained. Mean ADC values of benign and malignant neck lesions were measured and compared statistically. A total of 15 (46.9%) malignant masses and 17 (53.1%) benign masses were determined. Of all the neck masses, the ADC value of cystic masses was the highest and that of lymphomas was the lowest. The mean ADC values of benign and malignant neck masses were 1.57 × 10 -3 mm²/s and 0.90 × 10 -3 mm²/s, respectively. The difference between mean ADC values of benign and malignant neck masses was significant ( p < 0.01). Diffusion-weighted MRI with ADC measurements can be useful in the differential diagnosis of neck masses.
The Preclinical Alzheimer Cognitive Composite
Donohue, Michael C.; Sperling, Reisa A.; Salmon, David P.; Rentz, Dorene M.; Raman, Rema; Thomas, Ronald G.; Weiner, Michael; Aisen, Paul S.
2015-01-01
IMPORTANCE As Alzheimer disease (AD) research moves to intervene in presymptomatic phases of the disease, we must develop outcome measures sensitive to the earliest disease-related changes. OBJECTIVE To demonstrate the feasibility of a cognitive composite outcome for clinically normal elderly participants with evidence of AD pathology using the ADCS Preclinical Alzheimer Cognitive Composite (ADCS-PACC). The ADCS-PACC combines tests that assess episodic memory, timed executive function, and global cognition. The ADCS-PACC is the primary outcome measure for the first clinical trial in preclinical AD (ie, the Anti-Amyloid Treatment in Asymptomatic Alzheimer’s study). DESIGN, SETTING, AND PARTICIPANTS With the ADCS-PACC, we derive pilot estimates of amyloid-related decline using data from 2 observational studies conducted in North America and another conducted in Australia. The participants analyzed had normal cognition and mean ages of 75.81, 71.37, and 79.42 years across the 3 studies. MAIN OUTCOMES AND MEASURES For the 2 studies that collected data on Aβ levels (ADNI and AIBL), we estimate decline in a preclinical AD “Aβ-positive” placebo group and compare them with an “Aβ-negative” group. For the study that did not include data on Aβ levels (the ADCS Prevention Instrument [ADCS-PI] study), we grouped participants by the presence of APOE-ɛ4 and by clinical progression. RESULTS In ADNI, Aβ-positive participants showed more decline than did Aβ-negative participants with regard to the ADCS-PACC score at 24 months (mean [SE] difference, −1.239 [0.522] [95% CI, −2.263 to −0.215]; P = .02). In AIBL, the mean (SE) difference is significant at both 18 months (−1.009 [0.406] [95% CI, −1.805 to −0.213]; P = .01) and 36 months (−1.404 [0.452] [95% CI, −2.290 to −0.519]; P = .002). In the ADCS-PI study, APOE-ɛ4 allele carriers performed significantly worse on the ADCS-PACC at 24 months (mean [SE] score, −0.742 [0.294] [95% CI, −1.318 to −0.165]; P = .01) and 36 months (−1.531 [0.469] [95% CI, −2.450 to −0.612]; P = .001). In the ADCS-PI study, cognitively normal participants who progress from a global Clinical Dementia Rating score of 0 are significantly worse on the ADCS-PACC than cognitively normal participants who are stable with a global Clinical Dementia Rating score of 0 at months 12, 24, and 36 (mean [SE] ADCS-PACC score, −4.471 [0.702] [95% CI, −5.848 to −3.094]; P < .001). Using pilot estimates of variance and assuming 500 participants per group with 30% attrition and a 5% α level, we project 80% power to detect effects in the range of Δ = 0.467 to 0.733 on the ADCS-PACC. CONCLUSIONS AND RELEVANCE Analyses of at-risk cognitively normal populations suggest that we can reliably measure the first signs of cognitive decline with the ADCS-PACC. These analyses also suggest the feasibility of secondary prevention trials. PMID:24886908
Interpolation algorithm for asynchronous ADC-data
NASA Astrophysics Data System (ADS)
Bramburger, Stefan; Zinke, Benny; Killat, Dirk
2017-09-01
This paper presents a modified interpolation algorithm for signals with variable data rate from asynchronous ADCs. The Adaptive weights Conjugate gradient Toeplitz matrix (ACT) algorithm is extended to operate with a continuous data stream. An additional preprocessing of data with constant and linear sections and a weighted overlap of step-by-step into spectral domain transformed signals improve the reconstruction of the asycnhronous ADC signal. The interpolation method can be used if asynchronous ADC data is fed into synchronous digital signal processing.
Wu, Chen-Jiang; Wang, Qing; Li, Hai; Wang, Xiao-Ning; Liu, Xi-Sheng; Shi, Hai-Bin; Zhang, Yu-Dong
2015-10-01
To investigate diagnostic efficiency of DWI using entire-tumor histogram analysis in differentiating the low-grade (LG) prostate cancer (PCa) from intermediate-high-grade (HG) PCa in comparison with conventional ROI-based measurement. DW images (b of 0-1400 s/mm(2)) from 126 pathology-confirmed PCa (diameter >0.5 cm) in 110 patients were retrospectively collected and processed by mono-exponential model. The measurement of tumor apparent diffusion coefficients (ADCs) was performed with using histogram-based and ROI-based approach, respectively. The diagnostic ability of ADCs from two methods for differentiating LG-PCa (Gleason score, GS ≤ 6) from HG-PCa (GS > 6) was determined by ROC regression, and compared by McNemar's test. There were 49 LG-tumor and 77 HG-tumor at pathologic findings. Histogram-based ADCs (mean, median, 10th and 90th) and ROI-based ADCs (mean) showed dominant relationships with ordinal GS of Pca (ρ = -0.225 to -0.406, p < 0.05). All above imaging indices reflected significant difference between LG-PCa and HG-PCa (all p values <0.01). Histogram 10th ADCs had dominantly high Az (0.738), Youden index (0.415), and positive likelihood ratio (LR+, 2.45) in stratifying tumor GS against mean, median and 90th ADCs, and ROI-based ADCs. Histogram mean, median, and 10th ADCs showed higher specificity (65.3%-74.1% vs. 44.9%, p < 0.01), but lower sensitivity (57.1%-71.3% vs. 84.4%, p < 0.05) than ROI-based ADCs in differentiating LG-PCa from HG-PCa. DWI-associated histogram analysis had higher specificity, Az, Youden index, and LR+ for differentiation of PCa Gleason grade than ROI-based approach.
Can histogram analysis of MR images predict aggressiveness in pancreatic neuroendocrine tumors?
De Robertis, Riccardo; Maris, Bogdan; Cardobi, Nicolò; Tinazzi Martini, Paolo; Gobbo, Stefano; Capelli, Paola; Ortolani, Silvia; Cingarlini, Sara; Paiella, Salvatore; Landoni, Luca; Butturini, Giovanni; Regi, Paolo; Scarpa, Aldo; Tortora, Giampaolo; D'Onofrio, Mirko
2018-06-01
To evaluate MRI derived whole-tumour histogram analysis parameters in predicting pancreatic neuroendocrine neoplasm (panNEN) grade and aggressiveness. Pre-operative MR of 42 consecutive patients with panNEN >1 cm were retrospectively analysed. T1-/T2-weighted images and ADC maps were analysed. Histogram-derived parameters were compared to histopathological features using the Mann-Whitney U test. Diagnostic accuracy was assessed by ROC-AUC analysis; sensitivity and specificity were assessed for each histogram parameter. ADC entropy was significantly higher in G2-3 tumours with ROC-AUC 0.757; sensitivity and specificity were 83.3 % (95 % CI: 61.2-94.5) and 61.1 % (95 % CI: 36.1-81.7). ADC kurtosis was higher in panNENs with vascular involvement, nodal and hepatic metastases (p= .008, .021 and .008; ROC-AUC= 0.820, 0.709 and 0.820); sensitivity and specificity were: 85.7/74.3 % (95 % CI: 42-99.2 /56.4-86.9), 36.8/96.5 % (95 % CI: 17.2-61.4 /76-99.8) and 100/62.8 % (95 % CI: 56.1-100/44.9-78.1). No significant differences between groups were found for other histogram-derived parameters (p >.05). Whole-tumour histogram analysis of ADC maps may be helpful in predicting tumour grade, vascular involvement, nodal and liver metastases in panNENs. ADC entropy and ADC kurtosis are the most accurate parameters for identification of panNENs with malignant behaviour. • Whole-tumour ADC histogram analysis can predict aggressiveness in pancreatic neuroendocrine neoplasms. • ADC entropy and kurtosis are higher in aggressive tumours. • ADC histogram analysis can quantify tumour diffusion heterogeneity. • Non-invasive quantification of tumour heterogeneity can provide adjunctive information for prognostication.
Ruberti, M; Yun, R; Gokhberg, K; Kopelke, S; Cederbaum, L S; Tarantelli, F; Averbukh, V
2014-05-14
Here, we extend the L2 ab initio method for molecular photoionization cross-sections introduced in Gokhberg et al. [J. Chem. Phys. 130, 064104 (2009)] and benchmarked in Ruberti et al. [J. Chem. Phys. 139, 144107 (2013)] to the calculation of total photoionization cross-sections of molecules in electronically excited states. The method is based on the ab initio description of molecular electronic states within the many-electron Green's function approach, known as algebraic diagrammatic construction (ADC), and on the application of Stieltjes-Chebyshev moment theory to Lanczos pseudospectra of the ADC electronic Hamiltonian. The intermediate state representation of the dipole operator in the ADC basis is used to compute the transition moments between the excited states of the molecule. We compare the results obtained using different levels of the many-body theory, i.e., ADC(1), ADC(2), and ADC(2)x for the first two excited states of CO, N2, and H2O both at the ground state and the excited state equilibrium or saddle point geometries. We find that the single excitation ADC(1) method is not adequate even at the qualitative level and that the inclusion of double electronic excitations for description of excited state photoionization is essential. Moreover, we show that the use of the extended ADC(2)x method leads to a substantial systematic difference from the strictly second-order ADC(2). Our calculations demonstrate that a theoretical modelling of photoionization of excited states requires an intrinsically double excitation theory with respect to the ground state and cannot be achieved by the standard single excitation methods with the ground state as a reference.
Kikuchi, Ken; Shigihara, Takeshi; Hashimoto, Yuko; Miyajima, Masayuki; Haga, Nobuhiro; Kojima, Yoshiyuki; Shishido, Fumio
2017-01-01
Abstract AIMS: To evaluate the relationship between the apparent diffusion coefficient (ADC) value for bladder cancer and the recurrence/progression risk of post-transurethral resection (TUR). METHODS: Forty-one patients with initial and non-muscle-invasive bladder cancer underwent MRI from 2009 to 2012. Two radiologists measured ADC values. A pathologist calculated the recurrence/progression scores, and risk was classified based on the scores. Pearson’s correlation was used to analyze the correlations of ADC value with each score and with each risk group, and the optimal cut-off value was established based on receiver operating characteristic (ROC) curve analysis. Furthermore, the relationship between actual recurrence / progression of cases and ADC values was examined by Unpaird U test. RESULTS: There were significant correlations between ADC value and the recurrence score as well as the progression score (P<0.01, P<0.01, respectively). There were also significant correlations between ADC value and the recurrence risk group as well as progression risk group (P=0.042, P<0.01, respectively). The ADC cut-off value on ROC analysis was 1.365 (sensitivity 100%; specificity 97.4%) for the low and intermediate recurrence risk groups, 1.024 (sensitivity 47.4%; specificity 100%) for the intermediate and high recurrence risk groups, 1.252 (sensitivity 83.3%; specificity 81.3%) for the low and intermediate progression risk groups, and 0.955 (sensitivity 87.5%; specificity 63.2%) between the intermediate and high progression risk groups. The difference between the ADC values of the recurrence and nonrecurrence group in Unpaired t test was significant (P<0.05). CONCLUSION: ADC on MRI in bladder cancer could potentially be useful, non-invasive measurement for estimating the risks of recurrence and progression. PMID:28680010
Emmer, Kristel L; Wieczorek, Lindsay; Tuyishime, Steven; Molnar, Sebastian; Polonis, Victoria R; Ertl, Hildegund C J
2016-10-23
Over 2 million individuals are infected with HIV type 1 (HIV-1) each year, yet an effective vaccine remains elusive. The most successful HIV-1 vaccine to date demonstrated 31% efficacy. Immune correlate analyses associated HIV-1 envelope (Env)-specific antibodies with protection, thus providing a path toward a more effective vaccine. We sought to test the antibody response from novel prime-boost vaccination with a chimpanzee-derived adenovirus (AdC) vector expressing a subtype C Env glycoprotein (gp)140 combined with either a serologically distinct AdC vector expressing gp140 of a different subtype C isolate or an alum-adjuvanted, partially trimeric gp145 from yet another subtype C isolate. Three different prime-boost regimens were tested in mice: AdC prime-protein boost, protein prime-AdC boost, and AdC prime-AdC boost. Each regimen was tested at two different doses of AdC vector in a total of six experimental groups. Sera were collected at various time points and evaluated by ELISA for Env-specific antibody binding, isotype, and avidity. Antibody functionality was assessed by pseudovirus neutralization assay. Priming with AdC followed by a protein boost or sequential immunizations with two AdC vectors induced HIV-1 Env-specific binding antibodies, including those to the variable region 2, whereas priming with protein followed by an AdC boost was relatively ineffective. Antibodies that cross-neutralized tier 1 HIV-1 from different subtypes were elicited with vaccine regimens that included immunizations with protein. Our study warrants further investigation of AdC vector and gp145 protein prime-boost vaccines and their ability to protect against acquisition in animal challenge studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ruberti, M.; Yun, R.; Averbukh, V.
2014-05-14
Here, we extend the L{sup 2} ab initio method for molecular photoionization cross-sections introduced in Gokhberg et al. [J. Chem. Phys. 130, 064104 (2009)] and benchmarked in Ruberti et al. [J. Chem. Phys. 139, 144107 (2013)] to the calculation of total photoionization cross-sections of molecules in electronically excited states. The method is based on the ab initio description of molecular electronic states within the many-electron Green's function approach, known as algebraic diagrammatic construction (ADC), and on the application of Stieltjes-Chebyshev moment theory to Lanczos pseudospectra of the ADC electronic Hamiltonian. The intermediate state representation of the dipole operator in themore » ADC basis is used to compute the transition moments between the excited states of the molecule. We compare the results obtained using different levels of the many-body theory, i.e., ADC(1), ADC(2), and ADC(2)x for the first two excited states of CO, N{sub 2}, and H{sub 2}O both at the ground state and the excited state equilibrium or saddle point geometries. We find that the single excitation ADC(1) method is not adequate even at the qualitative level and that the inclusion of double electronic excitations for description of excited state photoionization is essential. Moreover, we show that the use of the extended ADC(2)x method leads to a substantial systematic difference from the strictly second-order ADC(2). Our calculations demonstrate that a theoretical modelling of photoionization of excited states requires an intrinsically double excitation theory with respect to the ground state and cannot be achieved by the standard single excitation methods with the ground state as a reference.« less
Iannicelli, Elsa; Di Pietropaolo, Marco; Pilozzi, Emanuela; Osti, Mattia Falchetto; Valentino, Maria; Masoni, Luigi; Ferri, Mario
2016-10-01
The aim of our study was to assess the performance value of magnetic resonance imaging (MRI) in the restaging of locally advanced rectal cancer after neoadjuvant chemoradiotherapy (CRT) and in the identification of good vs. poor responders to neoadjuvant therapy. A total of 34 patients with locally advanced rectal cancer underwent MRI prior to and after CRT. T stage and tumor regression grade (TRG) on post-CRT MRI was compared with the pathological staging ypT and TRG. Tumor volume and the apparent diffusion coefficient (ADC) were measured using diffusion-weighted imaging (DWI) before and after neoadjuvant CRT; the percentage of tumor volume reduction and the change of ADC (ΔADC) was also calculated. ADC parameters and the percentage of tumor volume reduction were correlated to histopathological results. The diagnostic performance of ADC and volume reduction to assess tumor response was evaluated by calculating the area under the ROC curve and the optimal cut-off values. A significant correlation between the T stage and the TRG defined in DW-MRI after CRT and the ypT and the TRG observed on the surgical specimens was found (p = 0.001; p < 0.001). The mean post-CRT ADC and ΔADC in responder patients was significantly higher compared to non-responder ones (p = 0.001; p = 0.01). Furthermore, the mean post-CRT ADC values were significantly higher in tumors with T-downstage (p = 0.01). DW-MRI may have a significant role in the restaging and in the evaluation of post-CRT response of locally advanced rectal cancer. Quantitative analysis of DWI through ADC map may result in a promising noninvasive tool to evaluate the response to therapy.
NASA Technical Reports Server (NTRS)
Toms, David; Hadden, George D.; Harrington, Jim
1990-01-01
The Maintenance and Diagnostic System (MDS) that is being developed at Honeywell to enhance the Fault Detection Isolation and Recovery system (FDIR) for the Attitude Determination and Control System on Space Station Freedom is described. The MDS demonstrates ways that AI-based techniques can be used to improve the maintainability and safety of the Station by helping to resolve fault anomalies that cannot be fully determined by built-in-test, by providing predictive maintenance capabilities, and by providing expert maintenance assistance. The MDS will address the problems associated with reasoning about dynamic, continuous information versus only about static data, the concerns of porting software based on AI techniques to embedded targets, and the difficulties associated with real-time response. An initial prototype was built of the MDS. The prototype executes on Sun and IBM PS/2 hardware and is implemented in the Common Lisp; further work will evaluate its functionality and develop mechanisms to port the code to Ada.
Fast data transmission in dynamic data acquisition system for plasma diagnostics
NASA Astrophysics Data System (ADS)
Byszuk, Adrian; Poźniak, Krzysztof; Zabołotny, Wojciech M.; Kasprowicz, Grzegorz; Wojeński, Andrzej; Cieszewski, Radosław; Juszczyk, Bartłomiej; Kolasiński, Piotr; Zienkiewicz, Paweł; Chernyshova, Maryna; Czarski, Tomasz
2014-11-01
This paper describes architecture of a new data acquisition system (DAQ) targeted mainly at plasma diagnostic experiments. Modular architecture, in combination with selected hardware components, allows for straightforward reconfiguration of the whole system, both offline and online. Main emphasis will be put into the implementation of data transmission subsystem in said system. One of the biggest advantages of described system is modular architecture with well defined boundaries between main components: analog frontend (AFE), digital backplane and acquisition/control software. Usage of a FPGA chips allows for a high flexibility in design of analog frontends, including ADC <--> FPGA interface. Data transmission between backplane boards and user software was accomplished with the use of industry-standard PCI Express (PCIe) technology. PCIe implementation includes both FPGA firmware and Linux device driver. High flexibility of PCIe connections was accomplished due to use of configurable PCIe switch. Whenever it's possible, described DAQ system tries to make use of standard off-the-shelf (OTF) components, including typical x86 CPU & motherboard (acting as PCIe controller) and cabling.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, X; Dalah, E; Prior, P
Purpose: Apparent diffusion coefficient (ADC) map may help to delineate the gross tumor volume (GTV) in prostate gland. Dose painting with external beam radiotherapy for GTV might increase the local tumor control. The purpose of this study is to explore the maximum boosting dose on GTV using VMAT without sacrificing sparing of organs at risk (OARs) in MRI based planning. Methods: VMAT plans for 5 prostate patients were generated following the commonly used dose volume (DV) criteria based on structures contoured on T2 weighted MRI with bulk electron density assignment using electron densities derived from ICRU46. GTV for each patientmore » was manually delineated based on ADC maps and fused to T2-weighted image set for planning study. A research planning system with Monte Carlo dose engine (Monaco, Elekta) was used to generate the VMAT plans with boosting dose on GTV gradually increased from 85Gy to 100Gy. DV parameters, including V(boosting-dose) (volume covered by boosting dose) for GTV, V75.6Gy for PTV, V45Gy, V70Gy, V72Gy and D1cc (Maximum dose to 1cc volume) for rectum and bladder, were used to measure plan quality. Results: All cases achieve at least 99.0% coverage of V(boosting-dose) on GTV and 95% coverage of V75.6Gy to the PTV. All the DV criteria, V45Gy≤50% and V70Gy≤15% for bladder and rectum, D1cc ≤77Gy (Rectum) and ≤80Gy (Bladder), V72Gy≤5% (rectum and bladder) were maintained when boosting GTV to 95Gy for all cases studied. Except for two patients, all the criteria were also met when the boosting dose goes to 100Gy. Conclusion: It is dosimetrically feasible safe to boost the dose to at least 95Gy to ADC defined GTV in prostate cancer using MRI guided VMAT delivery. Conclusion: It is dosimetrically feasible safe to boost the dose to at least 95Gy to ADC defined GTV in prostate cancer using MRI guided VMAT delivery. This research is partially supported by Elekta Inc.« less
Cui, Lei; Yin, Jian-Bing; Hu, Chun-Hong; Gong, Shen-Chu; Xu, Jun-Feng; Yang, Ju-Shun
2016-01-01
To prospectively evaluate the inter- and intraobserver agreement of apparent diffusion coefficient (ADC) measurements in free breathing, breath-hold, and respiratory triggered diffusion-weighted imaging (DWI) of lung cancer. Twenty-two patients with lung cancer (tumor size >2cm) underwent DWIs (3.0T) in three imaging methods. Lesion ADCs were measured twice by both of the two independent observers and compared. No statistical significance was found among methods, though respiratory-triggered DWI tended to have higher ADCs than breath-hold DWI. Great inter- and intraobserver agreement was shown. ADCs had good inter- and intraobserver agreement in all three DWI methods. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Woods, T. N.
2017-12-01
Nanosatellites, including the CubeSat class of nanosatellites, are about the size of a shoe box, and the CubeSat modular form factor of a Unit (1U is 10 cm x 10 cm x 10 cm) was originally defined in 1999 as a standardization for students developing nanosatellites. Over the past two decades, the satellite and instrument technologies for nanosatellites have progressed to the sophistication equivalent to the larger satellites, but now available in smaller packages through advanced developments by universities, government labs, and space industries. For example, the Blue Canyon Technologies (BCT) attitude determination and control system (ADCS) has demonstrated 3-axis satellite control from a 0.5-Unit system with 8 arc-second stability using reaction wheels, torque rods, and a star tracker. The first flight demonstration of the BCT ADCS was for the NASA Miniature X-ray Solar Spectrometer (MinXSS) CubeSat. The MinXSS CubeSat mission, which was deployed in May 2016 and had its re-entry in May 2017, provided space weather measurements of the solar soft X-rays (SXR) variability using low-power, miniaturized instruments. The MinXSS solar SXR spectra have been extremely useful for exploring flare energetics and also for validating the broadband SXR measurements from the NOAA GOES X-Ray Sensor (XRS). The technology used in the MinXSS CubeSat and summary of science results from the MinXSS-1 mission will be presented. Web site: http://lasp.colorado.edu/home/minxss/
Free-Flying Magnetometer Data System
NASA Technical Reports Server (NTRS)
Blaes, B.; Javadi, H.; Spencer, H.
2000-01-01
The Free-Flying Magnetometer (FFM) is an autonomous "sensorcraft" developed at the Jet Propulsion Laboratory (JPL) for the Enstrophy sounding rocket mission. This mission was a collaborative project between the University of New Hampshire, Cornell University and JPL. The science goal of the mission was the study of current filamentation phenomena in the northern auroral region through multipoint measurements of magnetic field. The technical objective of the mission was the proof of concept of the JPL FFM design and the demonstration of an in-situ multipoint measurement technique employing many free-flying spacecraft. Four FFMs were successfully deployed from a sounding rocket launched from Poker Flats, Alaska on February 11, 1999. These hockey-puck-sized (80 mm diameter, 38 mm. height, 250 gram mass) free flyers each carry a miniature 3-axis flux-gate magnetometer that output +/- 2 V signals corresponding to a +/- 60,000 nT measurement range for each axis. The FFM uses a synchronized four-channel Sigma(Delta) Analog-to-Digital Converter (ADC) having a dynamic range of +/- 2.5V and converting at a rate of 279 samples/second/channel. Three channels are used to digitize the magnetometer signals to 17-bit (1.144 nT/bit) resolution. The fourth ADC channel is multiplexed for system monitoring of four temperature sensors and two battery voltages. The FFM also contains two sun sensors, a laser diode which emits a fan-shaped beam, a miniature S-band transmitter for direct communication to the ground station antennas, an ultra-stable Temperature Compensated Crystal Oscillator (TCXO) clock, an integrated data subsystem implemented in a Field-Programmable Gate Array (FPGA), a 4 Mbit Static Random Access Memory (SRAM) for data storage and Lithium Thionyl Chloride batteries for power. Communicating commands to the FFM prior to deployment is achieved with an infrared (IR) link. The FFM IR receiver responds to 9-bit pulse coded signals that are generated by an IR Light Emitting Diode (LED) in the payload for turning FFM power on or off and placing the FFM in a test mode or flight mode. The IR links are also used to synchronize (zero) the clocks onboard all the FFMs through a reset pulse originating from the payload GPS receiver that is issued when the FFMs are in flight mode. The FPGA based data subsystem manages continuous data collection from the four ADC channels and sun sensors, formatting and storing the data to SRAM, and controlling downlink transmission. The transmitter is powered only after a 2547 frame SRAM buffer has been filled (approx. 5 minutes of data). The data is Viterbi encoded and sent to the S-band transmitter via a First-In-First-Out (FIFO) buffer who's output is clocked at 100 bits/second. After the 26-second transmission, the transmitter is turned off to reduce noise coupling to the sensitive magnetometer. The data subsystem control consists of a master state machine that performs data flow management and is interfaced through a prioritized interrupt scheme to state machines that service the ADC, sun sensors and transmitter FIFO. Continuous data collection prevents the missing of data during transmission and provides implicit time tagging of the data acquired by the ADC because of synchronization with the TCXO clock.
Fast ADC based multichannel acquisition system for the GEM detector
NASA Astrophysics Data System (ADS)
Kasprowicz, G.; Czarski, T.; Chernyshova, M.; Dominik, W.; Jakubowska, K.; Karpinski, L.; Kierzkowski, K.; Pozniak, K.; Rzadkiewicz, J.; Scholz, M.; Zabolotny, W.
2012-05-01
A novel approach to the Gas Electron Multiplier1 (GEM) detector readout is presented. Unlike commonly used methods, based on discriminators, and analogue FIFOs,[ the method developed uses simultaneously sampling high speed ADCs and advanced FPGA-based processing logic to estimate the energy of every single photon. Such method is applied to every GEM strip signal. It is especially useful in case of crystal-based spectrometers for soft X-rays, where higher order reflections need to be identified and rejected. For the purpose of the detector readout, a novel conception of the measurement platform was developed.
Zukotynski, Katherine A; Vajapeyam, Sridhar; Fahey, Frederic H; Kocak, Mehmet; Brown, Douglas; Ricci, Kelsey I; Onar-Thomas, Arzu; Fouladi, Maryam; Poussaint, Tina Young
2017-08-01
The purpose of this study was to describe baseline 18 F-FDG PET voxel characteristics in pediatric diffuse intrinsic pontine glioma (DIPG) and to correlate these metrics with baseline MRI apparent diffusion coefficient (ADC) histogram metrics, progression-free survival (PFS), and overall survival. Methods: Baseline brain 18 F-FDG PET and MRI scans were obtained in 33 children from Pediatric Brain Tumor Consortium clinical DIPG trials. 18 F-FDG PET images, postgadolinium MR images, and ADC MR images were registered to baseline fluid attenuation inversion recovery MR images. Three-dimensional regions of interest on fluid attenuation inversion recovery MR images and postgadolinium MR images and 18 F-FDG PET and MR ADC histograms were generated. Metrics evaluated included peak number, skewness, and kurtosis. Correlation between PET and MR ADC histogram metrics was evaluated. PET pixel values within the region of interest for each tumor were plotted against MR ADC values. The association of these imaging markers with survival was described. Results: PET histograms were almost always unimodal (94%, vs. 6% bimodal). None of the PET histogram parameters (skewness or kurtosis) had a significant association with PFS, although a higher PET postgadolinium skewness tended toward a less favorable PFS (hazard ratio, 3.48; 95% confidence interval [CI], 0.75-16.28 [ P = 0.11]). There was a significant association between higher MR ADC postgadolinium skewness and shorter PFS (hazard ratio, 2.56; 95% CI, 1.11-5.91 [ P = 0.028]), and there was the suggestion that this also led to shorter overall survival (hazard ratio, 2.18; 95% CI, 0.95-5.04 [ P = 0.067]). Higher MR ADC postgadolinium kurtosis tended toward shorter PFS (hazard ratio, 1.30; 95% CI, 0.98-1.74 [ P = 0.073]). PET and MR ADC pixel values were negatively correlated using the Pearson correlation coefficient. Further, the level of PET and MR ADC correlation was significantly positively associated with PFS; tumors with higher values of ADC-PET correlation had more favorable PFS (hazard ratio, 0.17; 95% CI, 0.03-0.89 [ P = 0.036]), suggesting that a higher level of negative ADC-PET correlation leads to less favorable PFS. A more significant negative correlation may indicate higher-grade elements within the tumor leading to poorer outcomes. Conclusion: 18 F-FDG PET and MR ADC histogram metrics in pediatric DIPG demonstrate different characteristics with often a negative correlation between PET and MR ADC pixel values. A higher negative correlation is associated with a worse PFS, which may indicate higher-grade elements within the tumor. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.
Morita, Koichiro; Nishie, Akihiro; Asayama, Yoshiki; Ishigami, Kousei; Ushijima, Yasuhiro; Takayama, Yukihisa; Okamoto, Daisuke; Fujita, Nobuhiro; Ikegami, Toru; Yoshizumi, Tomoharu; Shirabe, Ken; Honda, Hiroshi
2017-05-01
To elucidate the relationship between the ADCs of the liver graft and the remnant liver and the degree of liver regeneration in LDLT. 15 recipients and 15 corresponding donors underwent magnetic resonance imaging and computed tomography 1-2 weeks after living donor liver transplantation (LDLT). For diffusion-weighted imaging (DWI), a single-shot echo-planar sequence with b-factors of 0, 500, and 1000s/mm 2 was scanned. ADCs of the liver parenchyma were calculated at b factors of 0 and 500 and 1000 (ADC 0-500-1000) or 0 and 500 (ADC 0-500) or 500 and 1000 (ADC 500-1000). The liver volume ratio at LDLT, the mean ADCs and the regeneration rate were compared between the graft and the remnant liver using paired-t tests. The mean liver volume ratio of the recipients (41.3±9.8%) tended to be smaller than that of the donors (51.8±13.8%). The mean ADC 0-500 of the remnant liver (1.72±0.33) was significantly higher than that of the graft (1.43±0.32). The regeneration rate of the graft (2.07±0.41) was significantly higher than that of the remnant liver (1.53±0.49). ADC 0-500 can describe differences in blood perfusion between liver grafts and the remnant liver according to the degree of liver regeneration. Copyright © 2017 Elsevier B.V. All rights reserved.
Puthenveetil, Sujiet; He, Haiyin; Loganzo, Frank; Musto, Sylvia; Teske, Jesse; Green, Michael; Tan, Xingzhi; Hosselet, Christine; Lucas, Judy; Tumey, L Nathan; Sapra, Puja; Subramanyam, Chakrapani; O'Donnell, Christopher J; Graziani, Edmund I
2017-01-01
Antibody drug conjugates (ADCs) are no longer an unknown entity in the field of cancer therapy with the success of marketed ADCs like ADCETRIS and KADCYLA and numerous others advancing through clinical trials. The pursuit of novel cytotoxic payloads beyond the mictotubule inhibitors and DNA damaging agents has led us to the recent discovery of an mRNA splicing inhibitor, thailanstatin, as a potent ADC payload. In our previous work, we observed that the potency of this payload was uniquely tied to the method of conjugation, with lysine conjugates showing much superior potency as compared to cysteine conjugates. However, the ADC field is rapidly shifting towards site-specific ADCs due to their advantages in manufacturability, characterization and safety. In this work we report the identification of a highly efficacious site-specific thailanstatin ADC. The site of conjugation played a critical role on both the in vitro and in vivo potency of these ADCs. During the course of this study, we developed a novel methodology of loading a single site with multiple payloads using an in situ generated multi-drug carrying peptidic linker that allowed us to rapidly screen for optimal conjugation sites. Using this methodology, we were able to identify a double-cysteine mutant ADC delivering four-loaded thailanstatin that was very efficacious in a gastric cancer xenograft model at 3mg/kg and was also shown to be efficacious against T-DM1 resistant and MDR1 overexpressing tumor cell lines.
Antibody-Drug Conjugates (ADCs) for Personalized Treatment of Solid Tumors: A Review.
Lambert, John M; Morris, Charles Q
2017-05-01
Attaching a cytotoxic "payload" to an antibody to form an antibody-drug conjugate (ADC) provides a mechanism for selective delivery of the cytotoxic agent to cancer cells via the specific binding of the antibody to cancer-selective cell surface molecules. The first ADC to receive marketing authorization was gemtuzumab ozogamicin, which comprises an anti-CD33 antibody conjugated to a highly potent DNA-targeting antibiotic, calicheamicin, approved in 2000 for treating acute myeloid leukemia. It was withdrawn from the US market in 2010 following an unsuccessful confirmatory trial. The development of two classes of highly potent microtubule-disrupting agents, maytansinoids and auristatins, as payloads for ADCs resulted in approval of brentuximab vedotin in 2011 for treating Hodgkin lymphoma and anaplastic large cell lymphoma, and approval of ado-trastuzumab emtansine in 2013 for treating HER2-positive breast cancer. Their success stimulated much research into the ADC approach, with >60 ADCs currently in clinical evaluation, mostly targeting solid tumors. Five ADCs have advanced into pivotal clinical trials for treating various solid tumors-platinum-resistant ovarian cancer, mesothelioma, triple-negative breast cancer, glioblastoma, and small cell lung cancer. The level of target expression is a key parameter in predicting the likelihood of patient benefit for all these ADCs, as well as for the approved compound, ado-trastuzumab emtansine. The development of a patient selection strategy linked to target expression on the tumor is thus critically important for identifying the population appropriate for receiving treatment.
Functional decline in the elderly with MCI: Cultural adaptation of the ADCS-ADL scale.
Cintra, Fabiana Carla Matos da Cunha; Cintra, Marco Túlio Gualberto; Nicolato, Rodrigo; Bertola, Laiss; Ávila, Rafaela Teixeira; Malloy-Diniz, Leandro Fernandes; Moraes, Edgar Nunes; Bicalho, Maria Aparecida Camargos
2017-07-01
Translate, transcultural adaptation and application to Brazilian Portuguese of the Alzheimer's Disease Cooperative Study - Activities of Daily Living (ADCS-ADL) scale as a cognitive screening instrument. We applied the back translation added with pretest and bilingual methods. The sample was composed by 95 elderly individuals and their caregivers. Thirty-two (32) participants were diagnosed as mild cognitive impairment (MCI) patients, 33 as Alzheimer's disease (AD) patients and 30 were considered as cognitively normal individuals. There were only little changes on the scale. The Cronbach alpha coefficient was 0.89. The scores were 72.9 for control group, followed by MCI (65.1) and by AD (55.9), with a p-value < 0.001. The ROC curve value was 0.89. We considered a cut point of 72 and we observed a sensibility of 86.2%, specificity of 70%, positive predictive value of 86.2%, negative predictive value of 70%, positive likelihood ratio of 2.9 and negative likelihood ratio of 0.2. ADCS-ADL scale presents satisfactory psychometric properties to discriminate between MCI, AD and normal cognition.
Platform control for space-based imaging: the TOPSAT mission
NASA Astrophysics Data System (ADS)
Dungate, D.; Morgan, C.; Hardacre, S.; Liddle, D.; Cropp, A.; Levett, W.; Price, M.; Steyn, H.
2004-11-01
This paper describes the imaging mode ADCS design for the TOPSAT satellite, an Earth observation demonstration mission targeted at military applications. The baselined orbit for TOPSAT is a 600-700km sun synchronous orbit from which images up to 30° off track can be captured. For this baseline, the imaging camera proves a resolution of 2.5m and a nominal image size of 15x15km. The ADCS design solution for the imaging mode uses a moving demand approach to enable a single control algorithm solution for both the preparatory reorientation prior to image capture and the post capture return to nadir pointing. During image capture proper, control is suspended to minimise the disturbances experienced by the satellite from the wheels. Prior to each imaging sequence, the moving demand attitude and rate profiles are calculated such that the correct attitude and rate are achieved at the correct orbital position, enabling the correct target area to be captured.
Characterization of a Track-and-Hold Amplifier for Application to a High Performance SAR
DOE Office of Scientific and Technical Information (OSTI.GOV)
DUBBERT, DALE F.; HARDIN, TERRY LYNN; DELAPLAIN, GILBERT G.
2002-07-01
A Synthetic Aperture Radar (SAR) which employs direct IF sampling can significantly reduce the complexity of the analog electronics prior to the analog-to-digital converter (ADC). For relatively high frequency IF bands, a wide-bandwidth track-and-hold amplifier (THA) is required prior to the ADC. The THA functions primarily as a means of converting, through bandpass sampling, the IF signal to a baseband signal which can be sampled by the ADC. For a wide-band, high dynamic-range receiver system, such as a SAR receiver, stringent performance requirements are placed on the THA. We first measure the THA parameters such as gain, gain compression, third-ordermore » intercept (TOI), signal-to-noise ratio (SNR), spurious-free dynamic-range (SFDR), noise figure (NF), and phase noise. The results are then analyzed in terms of their respective impact on the overall performance of the SAR. The specific THA under consideration is the Rockwell Scientific RTH010.« less
Nielsen, Christoffer Fagernæs; van Putten, Sander Maarten; Lund, Ida Katrine; Melander, Maria Carlsén; Nørregaard, Kirstine Sandal; Jürgensen, Henrik Jessen; Reckzeh, Kristian; Christensen, Kristine Rothaus; Ingvarsen, Signe Ziir; Gårdsvoll, Henrik; Jensen, Kamilla Ellermann; Hamerlik, Petra; Engelholm, Lars Henning; Behrendt, Niels
2017-01-01
A key task in developing the field of personalized cancer therapy is the identification of novel molecular targets that enable treatment of cancers not susceptible to other means of specific therapy. The collagen receptor uPARAP/Endo180 is overexpressed by malignant cells in several non-epithelial cancers, notably including sarcomas, glioblastomas and subsets of acute myeloid leukemia. In contrast, in healthy adult individuals, expression is restricted to minor subsets of mesenchymal cells. Functionally, uPARAP/Endo180 is a rapidly recycling endocytic receptor that delivers its cargo directly into the endosomal-lysosomal system, thus opening a potential route of entry into receptor-positive cells. This combination of specific expression and endocytic function appears well suited for targeting of uPARAP/Endo180-positive cancers by antibody-drug conjugate (ADC) mediated drug delivery. Therefore, we utilized a specific monoclonal antibody against uPARAP/Endo180, raised through immunization of a uPARAP/Endo180 knock-out mouse, which reacts with both the human and the murine receptor, to construct a uPARAP-directed ADC. This antibody was coupled to the highly toxic dolastatin derivative, monomethyl auristatin E, via a cathepsin-labile valine-citrulline linker. With this ADC, we show strong and receptor-dependent cytotoxicity in vitro in uPARAP/Endo180-positive cancer cell lines of sarcoma, glioblastoma and leukemic origin. Furthermore, we demonstrate the potency of the ADC in vivo in a xenograft mouse model with human uPARAP/Endo180-positive leukemic cells, obtaining a complete cure of all tested mice following intravenous ADC treatment with no sign of adverse effects. Our study identifies uPARAP/Endo180 as a promising target for novel therapy against several highly malignant cancer types. PMID:28574834
Chen, Robert; O'Connor, Owen A.; Gopal, Ajay K.; Ramchandren, Radhakrishnan; Goy, Andre; Matous, Jeffrey V.; Fasanmade, Adedigbo A.; Manley, Thomas J.; Han, Tae H.
2016-01-01
Abstract Aims Brentuximab vedotin, an antibody–drug conjugate (ADC), selectively delivers the microtubule‐disrupting agent monomethyl auristatin E (MMAE) into CD30‐expressing cells. The pharmacokinetics of brentuximab vedotin have been characterized in patients with CD30‐positive haematologic malignancies. The primary objective of this phase 1 open label evaluation was to assess the pharmacokinetics of brentuximab vedotin in patients with hepatic or renal impairment. Methods Systemic exposures were evaluated following intravenous administration of 1.2 mg kg–1 brentuximab vedotin in patients with CD30‐positive haematologic malignancies and hepatic (n = 7) or renal (n = 10) impairment and compared with those of unimpaired patients (n = 8) who received 1.2 mg kg–1 brentuximab vedotin in another arm of the study. Results For any hepatic impairment, the ratios of geometric means (90% confidence interval) for AUC(0,∞) were 0.67 (0.48, 0.93) for ADC and 2.29 (1.27, 4.12) for MMAE. Mild or moderate renal impairment caused no apparent change in ADC or MMAE exposures. Severe renal impairment (creatinine clearance <30 ml min–1; n = 3) decreased ADC exposures (0.71 [0.54, 0.94]) and increased MMAE exposures (1.90 [0.85, 4.21]). No consistent pattern of specific adverse events was evident, but analysis of the safety data was confounded by the patients' poor baseline conditions. Five patients died due to adverse events considered unrelated to brentuximab vedotin. All had substantial comorbidities and most had poor baseline performance status. Conclusions Hepatic impairment and severe renal impairment may cause decreases in brentuximab vedotin ADC exposures and increases in MMAE exposures. PMID:27115790
High power-efficient asynchronous SAR ADC for IoT devices
NASA Astrophysics Data System (ADS)
Zhang, Beichen; Yao, Bingbing; Liu, Liyuan; Liu, Jian; Wu, Nanjian
2017-10-01
This paper presents a power-efficient 100-MS/s, 10-bit asynchronous successive approximation register (SAR) ADC. It includes an on-chip reference buffer and the total power dissipation is 6.8 mW. To achieve high performance with high power-efficiency in the proposed ADC, bootstrapped switch, redundancy, set-and-down switching approach, dynamic comparator and dynamic logic techniques are employed. The prototype was fabricated using 65 nm standard CMOS technology. At a 1.2-V supply and 100 MS/s, the ADC achieves an SNDR of 56.2 dB and a SFDR of 65.1 dB. The ADC core consumes only 3.1 mW, resulting in a figure of merit (FOM) of 30.27 fJ/conversionstep and occupies an active area of only 0.009 mm2.
Resistance to Antibody-Drug Conjugates.
García-Alonso, Sara; Ocaña, Alberto; Pandiella, Atanasio
2018-05-01
Antibody-drug conjugates (ADC) are multicomponent molecules constituted by an antibody covalently linked to a potent cytotoxic agent. ADCs combine high target specificity provided by the antibody together with strong antitumoral properties provided by the attached cytotoxic agent. At present, four ADCs have been approved and over 60 are being explored in clinical trials. Despite their effectiveness, resistance to these drugs unfortunately occurs. Efforts to understand the bases underlying such resistance are being carried out with the final purpose of counteracting them. In this review, we report described mechanisms of resistance to ADCs used in the clinic along with other potential ones that may contribute to resistance acquisition. We also discuss strategies to overcome resistance to ADCs. Cancer Res; 78(9); 2159-65. ©2018 AACR . ©2018 American Association for Cancer Research.
Intracellular trafficking of new anticancer therapeutics: antibody-drug conjugates.
Kalim, Muhammad; Chen, Jie; Wang, Shenghao; Lin, Caiyao; Ullah, Saif; Liang, Keying; Ding, Qian; Chen, Shuqing; Zhan, Jinbiao
2017-01-01
Antibody-drug conjugate (ADC) is a milestone in targeted cancer therapy that comprises of monoclonal antibodies chemically linked to cytotoxic drugs. Internalization of ADC takes place via clathrin-mediated endocytosis, caveolae-mediated endocytosis, and pinocytosis. Conjugation strategies, endocytosis and intracellular trafficking optimization, linkers, and drugs chemistry present a great challenge for researchers to eradicate tumor cells successfully. This inventiveness of endocytosis and intracellular trafficking has given considerable momentum recently to develop specific antibodies and ADCs to treat cancer cells. It is significantly advantageous to emphasize the endocytosis and intracellular trafficking pathways efficiently and to design potent engineered conjugates and biological entities to boost efficient therapies enormously for cancer treatment. Current studies illustrate endocytosis and intracellular trafficking of ADC, protein, and linker strategies in unloading and also concisely evaluate practically applicable ADCs.
Intracellular trafficking of new anticancer therapeutics: antibody–drug conjugates
Kalim, Muhammad; Chen, Jie; Wang, Shenghao; Lin, Caiyao; Ullah, Saif; Liang, Keying; Ding, Qian; Chen, Shuqing; Zhan, Jinbiao
2017-01-01
Antibody–drug conjugate (ADC) is a milestone in targeted cancer therapy that comprises of monoclonal antibodies chemically linked to cytotoxic drugs. Internalization of ADC takes place via clathrin-mediated endocytosis, caveolae-mediated endocytosis, and pinocytosis. Conjugation strategies, endocytosis and intracellular trafficking optimization, linkers, and drugs chemistry present a great challenge for researchers to eradicate tumor cells successfully. This inventiveness of endocytosis and intracellular trafficking has given considerable momentum recently to develop specific antibodies and ADCs to treat cancer cells. It is significantly advantageous to emphasize the endocytosis and intracellular trafficking pathways efficiently and to design potent engineered conjugates and biological entities to boost efficient therapies enormously for cancer treatment. Current studies illustrate endocytosis and intracellular trafficking of ADC, protein, and linker strategies in unloading and also concisely evaluate practically applicable ADCs. PMID:28814834
Winter, Karsten; Richter, Cindy; Hoehn, Anna-Kathrin
2018-01-01
Our purpose was to analyze associations between apparent diffusion coefficient (ADC) histogram analysis parameters and histopathologicalfeatures in head and neck squamous cell carcinoma (HNSCC). The study involved 32 patients with primary HNSCC. For every tumor, the following histogram analysis parameters were calculated: ADCmean, ADCmax, ADCmin, ADCmedian, ADCmode, P10, P25, P75, P90, kurtosis, skewness, and entropy. Furthermore, proliferation index KI 67, cell count, total and average nucleic areas were estimated. Spearman's correlation coefficient (p) was used to analyze associations between investigated parameters. In overall sample, all ADC values showed moderate inverse correlations with KI 67. All ADC values except ADCmax correlated inversely with tumor cellularity. Slightly correlations were identified between total/average nucleic area and ADCmean, ADCmin, ADCmedian, and P25. In G1/2 tumors, only ADCmode correlated well with Ki67. No statistically significant correlations between ADC parameters and cellularity were found. In G3 tumors, Ki 67 correlated with all ADC parameters except ADCmode. Cell count correlated well with all ADC parameters except ADCmax. Total nucleic area correlated inversely with ADCmean, ADCmin, ADCmedian, P25, and P90. ADC histogram parameters reflect proliferation potential and cellularity in HNSCC. The associations between histopathology and imaging depend on tumor grading. PMID:29805759
Zhou, Mei-Ling; Yan, Fu-Hua; Xu, Peng-Ju; Chen, Cai-Zhong; Shen, Ji-Zhang; Li, Ren-Chen; Ji, Yuan; Shi, Jian-Ying
2009-07-07
To evaluate the clinical practical value of apparent diffusion coefficient (ADC) measurements based on diffusion-weighted MR imaging (DWI) for quantification of liver fibrosis and inflammation for hepatitis viral infection. Diffusion-weighted MRI with parallel imaging was prospectively performed on 85 patients with chronic hepatitis and on 22 healthy volunteers within a single breath-hold using a single-shot spin-echo echo-planar sequence at b values of 100, 300, 500, 800 and 1000 s/mm2 respectively. ADC values of liver were measured with five different b values. The inflammation grades and fibrosis stages were evaluated histologically by biopsy. One-way analysis of variance and Spearman' s rank correlation test were used for statistical analysis. Receiver operating characteristics analysis was used to assess the performance of ADC in predicting the presence of stage > or = 2 and stage > or = 3 hepatic fibrosis, and grade > or = 1 hepatic inflammation. There was moderate negative correlation between hepatic ADC values and fibrosis stage. And the best correlation was obtained for a b value of 800 s/mm2 (r = -0.697, P = 0. 000). At all b values there was a significant decrease in hepatic ADC in patients with stage < or = 1 versus stage > or = 2 fibrosis and stage < or = 2 versus stage > or = 3 fibrosis (P < 0.05). Hepatic ADC was a significant predictor of stage > or = 2 and > or = 3 fibrosis. The areas under the curve were 0.909 vs 0.917, sensitivity 76.6% vs 80.0% and specificity 88.3% vs 91.5% (ADC with a b value of 800 s/mm2, 1.26 x 10(-3) mm2/s or less and 1.19 x 10(-3) mm2/s or less). There was weak to moderate negative correlation between ADCs and inflammation grade. Hepatic ADC was a significant predictor of grade > 1 inflammation with an area under the curve of 0.781, sensitivity of 60.0% and specificity of 86.4% (ADC with a b value of 500 s/mm2, 1.54 x 10(-3) mm2/s or less). The DWI measurement of hepatic ADC can be used to quantify liver fibrosis and inflammation. It will be a new approach for early diagnosis and therapeutic follow-up of hepatic fibrosis.
Kirby, Miranda; Ouriadov, Alexei; Svenningsen, Sarah; Owrangi, Amir; Wheatley, Andrew; Etemad‐Rezai, Roya; Santyr, Giles E.; McCormack, David G.; Parraga, Grace
2014-01-01
Abstract Noble gas pulmonary magnetic resonance imaging (MRI) is transitioning away from 3He to 129Xe gas, but the physiological/clinical relevance of 129Xe apparent diffusion coefficient (ADC) parenchyma measurements is not well understood. Therefore, our objective was to generate 129Xe MRI ADC for comparison with 3He ADC and with well‐established measurements of alveolar structure and function in older never‐smokers and ex‐smokers with chronic obstructive pulmonary disease (COPD). In four never‐smokers and 10 COPD ex‐smokers, 3He (b = 1.6 sec/cm2) and 129Xe (b = 12, 20, and 30 sec/cm2) ADC, computed tomography (CT) density‐threshold measurements, and the diffusing capacity for carbon monoxide (DLCO) were measured. To understand regional differences, the anterior–posterior (APG) and superior–inferior (∆SI) ADC differences were evaluated. Compared to never‐smokers, COPD ex‐smokers showed greater 3He ADC (P = 0.006), 129Xe ADCb12 (P = 0.006), and ADCb20 (P = 0.006), but not for ADCb30 (P > 0.05). Never‐smokers and COPD ex‐smokers had significantly different APG for 3He ADC (P = 0.02), 129Xe ADCb12 (P = 0.006), and ADCb20 (P = 0.01), but not for ADCb30 (P > 0.05). ∆SI for never‐ and ex‐smokers was significantly different for 3He ADC (P = 0.046), but not for 129Xe ADC (P > 0.05). There were strong correlations for DLCO with 3He ADC and 129Xe ADCb12 (both r = −0.95, P < 0.05); in a multivariate model 129Xe ADCb12 was the only significant predictor of DLCO (P = 0.049). For COPD ex‐smokers, CT relative area <−950 HU (RA950) correlated with 3He ADC (r = 0.90, P = 0.008) and 129Xe ADCb12 (r = 0.85, P = 0.03). In conclusion, while 129Xe ADCb30 may be appropriate for evaluating subclinical or mild emphysema, in this small group of never‐smokers and ex‐smokers with moderate‐to‐severe emphysema, 129Xe ADCb12 provided a physiologically appropriate estimate of gas exchange abnormalities and alveolar microstructure. PMID:25347853
Differential comparator cirucit
Hickling, Ronald M.
1996-01-01
A differential comparator circuit for an Analog-to-Digital Converter (ADC) or other application includes a plurality of differential comparators and a plurality of offset voltage generators. Each comparator includes first and second differentially connected transistor pairs having equal and opposite voltage offsets. First and second offset control transistors are connected in series with the transistor pairs respectively. The offset voltage generators generate offset voltages corresponding to reference voltages which are compared with a differential input voltage by the comparators. Each offset voltage is applied to the offset control transistors of at least one comparator to set the overall voltage offset of the comparator to a value corresponding to the respective reference voltage. The number of offset voltage generators required in an ADC application can be reduced by a factor of approximately two by applying the offset voltage from each offset voltage generator to two comparators with opposite logical sense such that positive and negative offset voltages are produced by each offset voltage generator.
A Digital Motion Control System for Large Telescopes
NASA Astrophysics Data System (ADS)
Hunter, T. R.; Wilson, R. W.; Kimberk, R.; Leiker, P. S.
2001-05-01
We have designed and programmed a digital motion control system for large telescopes, in particular, the 6-meter antennas of the Submillimeter Array on Mauna Kea. The system consists of a single robust, high-reliability microcontroller board which implements a two-axis velocity servo while monitoring and responding to critical safety parameters. Excellent tracking performance has been achieved with this system (0.3 arcsecond RMS at sidereal rate). The 24x24 centimeter four-layer printed circuit board contains a multitude of hardware devices: 40 digital inputs (for limit switches and fault indicators), 32 digital outputs (to enable/disable motor amplifiers and brakes), a quad 22-bit ADC (to read the motor tachometers), four 16-bit DACs (that provide torque signals to the motor amplifiers), a 32-LED status panel, a serial port to the LynxOS PowerPC antenna computer (RS422/460kbps), a serial port to the Palm Vx handpaddle (RS232/115kbps), and serial links to the low-resolution absolute encoders on the azimuth and elevation axes. Each section of the board employs independent ground planes and power supplies, with optical isolation on all I/O channels. The processor is an Intel 80C196KC 16-bit microcontroller running at 20MHz on an 8-bit bus. This processor executes an interrupt-driven, scheduler-based software system written in C and assembled into an EPROM with user-accessible variables stored in NVSRAM. Under normal operation, velocity update requests arrive at 100Hz from the position-loop servo process running independently on the antenna computer. A variety of telescope safety checks are performed at 279Hz including routine servicing of a 6 millisecond watchdog timer. Additional ADCs onboard the microcontroller monitor the winding temperature and current in the brushless three-phase drive motors. The PID servo gains can be dynamically changed in software. Calibration factors and software filters can be applied to the tachometer readings prior to the application of the servo gains in the torque computations. The Palm pilot handpaddle displays the complete status of the telescope and allows full local control of the drives in an intuitive, touchscreen user interface which is especially useful during reconfigurations of the antenna array.
A data acquisition system for coincidence imaging using a conventional dual head gamma camera
NASA Astrophysics Data System (ADS)
Lewellen, T. K.; Miyaoka, R. S.; Jansen, F.; Kaplan, M. S.
1997-06-01
A low cost data acquisition system (DAS) was developed to acquire coincidence data from an unmodified General Electric Maxxus dual head scintillation camera. A high impedance pick-off circuit provides position and energy signals to the DAS without interfering with normal camera operation. The signals are pulse-clipped to reduce pileup effects. Coincidence is determined with fast timing signals derived from constant fraction discriminators. A charge-integrating FERA 16 channel ADC feeds position and energy data to two CAMAC FERA memories operated as ping-pong buffers. A Macintosh PowerPC running Labview controls the system and reads the CAMAC memories. A CAMAC 12-channel scaler records singles and coincidence rate data. The system dead-time is approximately 10% at a coincidence rate of 4.0 kHz.
Schob, Stefan; Münch, Benno; Dieckow, Julia; Quäschling, Ulf; Hoffmann, Karl-Titus; Richter, Cindy; Garnov, Nikita; Frydrychowicz, Clara; Krause, Matthias; Meyer, Hans-Jonas; Surov, Alexey
2018-04-01
Diffusion weighted imaging (DWI) quantifies motion of hydrogen nuclei in biological tissues and hereby has been used to assess the underlying tissue microarchitecture. Histogram-profiling of DWI provides more detailed information on diffusion characteristics of a lesion than the standardly calculated values of the apparent diffusion coefficient (ADC)-minimum, mean and maximum. Hence, the aim of our study was to investigate, which parameters of histogram-profiling of DWI in primary central nervous system lymphoma can be used to specifically predict features like cellular density, chromatin content and proliferative activity. Pre-treatment ADC maps of 21 PCNSL patients (8 female, 13 male, 28-89 years) from a 1.5T system were used for Matlab-based histogram profiling. Results of histopathology (H&E staining) and immunohistochemistry (Ki-67 expression) were quantified. Correlations between histogram-profiling parameters and neuropathologic examination were calculated using SPSS 23.0. The lower percentiles (p10 and p25) showed significant correlations with structural parameters of the neuropathologic examination (cellular density, chromatin content). The highest percentile, p90, correlated significantly with Ki-67 expression, resembling proliferative activity. Kurtosis of the ADC histogram correlated significantly with cellular density. Histogram-profiling of DWI in PCNSL provides a comprehensible set of parameters, which reflect distinct tumor-architectural and tumor-biological features, and hence, are promising biomarkers for treatment response and prognosis. Copyright © 2018. Published by Elsevier Inc.
Episodic Memory in Detoxified Alcoholics: Contribution of Grey Matter Microstructure Alteration
Chanraud, Sandra; Leroy, Claire; Martelli, Catherine; Kostogianni, Nikoleta; Delain, Françoise; Aubin, Henri-Jean; Reynaud, Michel; Martinot, Jean-Luc
2009-01-01
Even though uncomplicated alcoholics may likely have episodic memory deficits, discrepancies exist regarding to the integrity of brain regions that underlie this function in healthy subjects. Possible relationships between episodic memory and 1) brain microstructure assessed by magnetic resonance diffusion tensor imaging (DTI), 2) brain volumes assessed by voxel-based morphometry (VBM) were investigated in uncomplicated, detoxified alcoholics. Diffusion and morphometric analyses were performed in 24 alcohol dependent men without neurological or somatic complications and in 24 healthy men. The mean apparent coefficient of diffusion (ADC) and grey matter volumes were measured in the whole brain. Episodic memory performance was assessed using a French version of the Free and Cued Selective Reminding Test (FCSRT). Correlation analyses between verbal episodic memory, brain microstructure, and brain volumes were carried out using SPM2 software. In those with alcohol dependence, higher ADC was detected mainly in frontal, temporal and parahippocampal regions, and in the cerebellum. In alcoholics, regions with higher ADC typically also had lower grey matter volume. Low verbal episodic memory performance in alcoholism was associated with higher mean ADC in parahippocampal areas, in frontal cortex and in the left temporal cortex; no correlation was found between regional volumes and episodic memory scores. Regression analyses for the control group were not significant. These findings support the hypothesis that regional microstructural but no macrostructural alteration of the brain might be responsible, at least in part, for episodic memory deficits in alcohol dependence. PMID:19707568
NASA Astrophysics Data System (ADS)
Tourell, Monique C.; Shokoohmand, Ali; Landgraf, Marietta; Holzapfel, Nina P.; Poh, Patrina S. P.; Loessner, Daniela; Momot, Konstantin I.
2017-02-01
Diffusion-weighted magnetic resonance imaging (DW-MRI) was used to evaluate the effects of single-agent and combination treatment regimens in a spheroid-based animal model of ovarian cancer. Ovarian tumour xenografts grown in non-obese diabetic/severe-combined-immunodeficiency (NOD/SCID) mice were treated with carboplatin or paclitaxel, or combination carboplatin/paclitaxel chemotherapy regimens. After 4 weeks of treatment, tumours were extracted and underwent DW-MRI, mechanical testing, immunohistochemical and gene expression analyses. The distribution of the apparent diffusion coefficient (ADC) exhibited an upward shift as a result of each treatment regimen. The 99-th percentile of the ADC distribution (“maximum ADC”) exhibited a strong correlation with the tumour size (r2 = 0.90) and with the inverse of the elastic modulus (r2 = 0.96). Single-agent paclitaxel (n = 5) and combination carboplatin/paclitaxel (n = 2) treatment regimens were more effective in inducing changes in regions of higher cell density than single-agent carboplatin (n = 3) or the no-treatment control (n = 5). The maximum ADC was a good indicator of treatment-induced cell death and changes in the extracellular matrix (ECM). Comparative analysis of the tumours’ ADC distribution, mechanical properties and ECM constituents provides insights into the molecular and cellular response of the ovarian tumour xenografts to chemotherapy. Increased sample sizes are recommended for future studies. We propose experimental approaches to evaluation of the timeline of the tumour’s response to treatment.
Targeting Functional Decline in Alzheimer Disease: A Randomized Trial.
Callahan, Christopher M; Boustani, Malaz A; Schmid, Arlene A; LaMantia, Michael A; Austrom, Mary G; Miller, Douglas K; Gao, Sujuan; Ferguson, Denisha Y; Lane, Kathleen A; Hendrie, Hugh C
2017-02-07
Alzheimer disease results in progressive functional decline, leading to loss of independence. To determine whether collaborative care plus 2 years of home-based occupational therapy delays functional decline. Randomized, controlled clinical trial. (ClinicalTrials.gov: NCT01314950). Urban public health system. 180 community-dwelling participants with Alzheimer disease and their informal caregivers. All participants received collaborative care for dementia. Patients in the intervention group also received in-home occupational therapy delivered in 24 sessions over 2 years. The primary outcome measure was the Alzheimer's Disease Cooperative Study Group Activities of Daily Living Scale (ADCS ADL); performance-based measures included the Short Physical Performance Battery (SPPB) and Short Portable Sarcopenia Measure (SPSM). At baseline, clinical characteristics did not differ significantly between groups; the mean Mini-Mental State Examination score for both groups was 19 (SD, 7). The intervention group received a median of 18 home visits from the study occupational therapists. In both groups, ADCS ADL scores declined over 24 months. At the primary end point of 24 months, ADCS ADL scores did not differ between groups (mean difference, 2.34 [95% CI, -5.27 to 9.96]). We also could not definitively demonstrate between-group differences in mean SPPB or SPSM values. The results of this trial are indeterminate and do not rule out potential clinically important effects of the intervention. The authors could not definitively demonstrate whether the addition of 2 years of in-home occupational therapy to a collaborative care management model slowed the rate of functional decline among persons with Alzheimer disease. This trial underscores the burden undertaken by caregivers as they provide care for family members with Alzheimer disease and the difficulty in slowing functional decline. National Institute on Aging.
Targeting Functional Decline: Results from the Alzheimer’s Disease Multiple Intervention Trial
Callahan, Christopher M.; Boustani, Malaz A.; Schmid, Arlene A.; LaMantia, Michael A.; Austrom, Mary G.; Miller, Douglas K.; Gao, Sujuan; Ferguson, Denisha Y.; Lane, Kathleen A.; Hendrie, Hugh C.
2017-01-01
Background Alzheimer’s disease (AD) results in progressive functional decline leading to loss of independence Objective To determine whether collaborative care plus two years of home-based occupational therapy delays functional decline Design Randomized controlled clinical trial Setting Urban public health system Patients 180 community-dwelling subjects who were diagnosed with AD and their informal caregivers Interventions All subjects received collaborative care for dementia. Intervention patients also received in-home occupational therapy delivered in 24 sessions over 2 years. Measurements The primary outcome measures was the Alzheimer’s Disease Cooperative Studies Group Activities of Daily Living Scale (ADCS ADL); performance based measures included the Short Physical Performance Battery (SPPB) and Short Portable Sarcopenia Measure (SPSM) Results At baseline, there were no significant between group differences in clinical characteristics; the mean MMSE for both groups was 19 (SD=7). The intervention group received a median of 18 home visits from the study occupational therapists. Both groups declined in ADCS ADL scores over 24 months. At the primary endpoint of 24 months, there were no between group differences in ADCS ADL scores (mean difference 2.34, 95% CI −5.27, 9.96). We were also unable to definitively demonstrate between-group differences in the mean SPPB or SPSM. Limitations The results of this trial are indeterminate and do not rule out potentially clinically important effects of the intervention. Conclusions We were unable to definitively demonstrate whether the addition of two years of in-home occupational therapy to a collaborative care management model slows the rate of functional decline among persons with AD. This trial underscores the burden undertaken by family caregivers as they provide care for persons with AD and the difficulty in slowing functional decline. PMID:27893087
Design and development of digital seismic amplifier recorder
DOE Office of Scientific and Technical Information (OSTI.GOV)
Samsidar, Siti Alaa; Afuar, Waldy; Handayani, Gunawan, E-mail: gunawanhandayani@gmail.com
2015-04-16
A digital seismic recording is a recording technique of seismic data in digital systems. This method is more convenient because it is more accurate than other methods of seismic recorders. To improve the quality of the results of seismic measurements, the signal needs to be amplified to obtain better subsurface images. The purpose of this study is to improve the accuracy of measurement by amplifying the input signal. We use seismic sensors/geophones with a frequency of 4.5 Hz. The signal is amplified by means of 12 units of non-inverting amplifier. The non-inverting amplifier using IC 741 with the resistor values 1KΩmore » and 1MΩ. The amplification results were 1,000 times. The results of signal amplification converted into digital by using the Analog Digital Converter (ADC). Quantitative analysis in this study was performed using the software Lab VIEW 8.6. The Lab VIEW 8.6 program was used to control the ADC. The results of qualitative analysis showed that the seismic conditioning can produce a large output, so that the data obtained is better than conventional data. This application can be used for geophysical methods that have low input voltage such as microtremor application.« less
Kang, Suna; Moon, Na Rang; Kim, Da Sol; Kim, Sung Hoon; Park, Sunmin
2015-09-01
Ghrelin is a gastric hormone released during the fasting state that targets the hypothalamus where it induces hunger; however, emerging evidence suggests it may also affect memory function. We examined the effect of central acylated-ghrelin and DES-acetylated ghrelin (native ghrelin) on memory function and glucose metabolism in an experimentally induced Alzheimer's disease (AD) rat model. AD rats were divided into 3 groups and Non-AD rats were used as a normal-control group. Each rat in the AD groups had intracerebroventricular (ICV) infusion of β-amyloid (25-35; 16.8nmol/day) into the lateral ventricle for 3 days, and then the pumps were changed to infuse either acylated-ghrelin (0.2nmol/h; AD-G), DES-acylated ghrelin (0.2nmol/h; AD-DES-G), or saline (control; AD-C) for 3 weeks. The Non-AD group had ICV infusion of β-amyloid (35-25) which does not deposit in the hippocampus. During the next 3 weeks memory function, food intake, body weight gain, body fat composition, and glucose metabolism were measured. AD-C exhibited greater β-amyloid deposition compared to Non-AD-C, and AD-G suppressed the increased β-amyloid deposition and potentiated the phosphorylation AMPK. In addition, AD-G increased the phosphorylation GSK and decreased the phosphorylation of Tau in comparison to AD-C and AD-DES-G. Cognitive function, measured by passive avoidance and water maze tests, was much lower in AD-C than Non-AD-C whereas AD-G but not AD-DES-G prevented the decrease (p<0.021). Body weight gain was lower in AD-C group than Non-AD-C group without changing epididymal fat mass. AD-G reversed the decrease in body weight which was due to increased energy intake and decreased energy expenditure. The AD-G group exhibited a decrease in the second part of serum glucose levels during an oral glucose tolerance test (OGTT) compared to the AD-C and AD-DES-G group (p<0.009). However, area under the curve of insulin during the first part of OGTT was higher in AD-DES-G than other groups, whereas during the second part it was suppressed in AD-G as much as Non-AD. In conclusion, central acylated ghrelin in rats prevented the deterioration of memory function, and energy and glucose metabolisms were partially improved, possibly due to less β-amyloid accumulation. This research suggests that interventions such as intermittent fasting to facilitate sustained elevations of acyl-ghrelin should be investigated for cognitive and metabolic benefits, especially in person with early symptoms of memory impairment. Copyright © 2015 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lahrsow, Maximilian, E-mail: mlahrsow@gmail.com; Albrecht, Moritz H.; Bickford, Matthew W.
PurposeTo use absolute pretreatment apparent diffusion coefficients (ADC) derived from diffusion-weighted MR imaging (DWI) to predict response to repetitive cTACE for unresectable liver metastases of colorectal carcinoma (CRLM) at 1 and 3 months after start of treatment.Materials and MethodsFifty-five metastases in 34 patients were examined with DWI prior to treatment and 1 month after initial cTACE. Treatment was performed in 4-week intervals. Response was evaluated at 1 and 3 months after start of therapy. Metastases showing a decrease of ≥30% in axial diameter were classified as responding lesions.ResultsOne month after initial cTACE, seven lesions showed early response. There was no significant differencemore » in absolute pretreatment ADC values between responding and non-responding lesions (p = 0.94). Three months after initial cTACE, 17 metastases showed response. There was a significant difference (p = 0.021) between absolute pretreatment ADC values of lesions showing response (median 1.08 × 10{sup −3} mm{sup 2}/s) and no response (median 1.30 × 10{sup −3} mm{sup 2}/s). Pretreatment ADC showed fair diagnostic value to predict response (AUC 0.7). Lesions showing response at 3 months also revealed a significant increase in ADC between measurements before treatment and at one month after initial cTACE (p < 0.001). Applying an increase in ADC of 12.17%, response at 3 months after initial cTACE could be predicted with a sensitivity and specificity of 77 and 74%, respectively (AUC 0.817). Furthermore, there was a strong and significant correlation (r = 0.651, p < 0.001) between percentage change in size after third cTACE and percentage change in ADC.ConclusionIn patients with CRLM, ADC measurements are potential biomarkers for assessing response to cTACE.« less
Guo, Yuan; Kong, Qing-Cong; Zhu, Ye-Qing; Liu, Zhen-Zhen; Peng, Ling-Rong; Tang, Wen-Jie; Yang, Rui-Meng; Xie, Jia-Jun; Liu, Chun-Ling
2018-02-01
To evaluate the utility of the whole-lesion histogram apparent diffusion coefficient (ADC) for characterizing the heterogeneity of mucinous breast carcinoma (MBC) and to determine which ADC metrics may help to best differentiate subtypes of MBC. This retrospective study involved 52 MBC patients, including 37 pure MBC (PMBC) and 15 mixed MBC (MMBC). The PMBC patients were subtyped into PMBC-A (20 cases) and PMBC-B (17 cases) groups. All patients underwent preoperative diffusion-weighted imaging (DWI) at 1.5T and the whole-lesion ADC assessments were generated. Histogram-derived ADC parameters were compared between PMBC vs. MMBC and PMBC-A vs. PMBC-B, and receiver operating characteristic (ROC) curve analysis was used to determine optimal histogram parameters for differentiating these groups. The PMBC group exhibited significantly higher ADC values for the mean (P = 0.004), 25 th (P = 0.004), 50 th (P = 0.004), 75 th (P = 0.006), and 90 th percentiles (P = 0.013) and skewness (P = 0.021) than did the MMBC group. The 25 th percentile of ADC values achieved the highest area under the curve (AUC) (0.792), with a cutoff value of 1.345 × 10 -3 mm 2 /s, in distinguishing PMBC and MMBC. The PMBC-A group showed significantly higher ADC values for the mean (P = 0.049), 25 th (P = 0.015), and 50 th (P = 0.026) percentiles and skewness (P = 0.004) than did the PMBC-B group. The 25 th percentile of the ADC cutoff value (1.476 × 10 -3 mm 2 /s) demonstrated the best AUC (0.837) among the ADC values for distinguishing PMBC-A and PMBC-B. Whole-lesion ADC histogram analysis enables comprehensive evaluation of an MBC in its entirety and differentiating subtypes of MBC. Thus, it may be a helpful and supportive tool for conventional MRI. 4 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:391-400. © 2017 International Society for Magnetic Resonance in Medicine.
Ye, Zhi-Min; Dai, Shu-Jun; Yan, Feng-Qin; Wang, Lei; Fang, Jun; Fu, Zhen-Fu; Wang, Yue-Zhen
2018-01-01
This study aimed to evaluate both the short- and long-term efficacies of chemoradiotherapy in relation to the treatment of esophageal cancer . This was achieved through the use of dynamic contrast-enhanced magnetic resonance imaging-derived volume transfer constant and diffusion weighted imaging-derived apparent diffusion coefficient . Patients with esophageal cancer were assigned into the sensitive and resistant groups based on respective efficacies in chemoradiotherapy. Dynamic contrast-enhanced magnetic resonance imaging and diffusion weighted imaging were used to measure volume transfer constant and apparent diffusion coefficient, while computed tomography was used to calculate tumor size reduction rate. Pearson correlation analyses were conducted to analyze correlation between volume transfer constant, apparent diffusion coefficient, and the tumor size reduction rate. Receiver operating characteristic curve was constructed to analyze the short-term efficacy of volume transfer constant and apparent diffusion coefficient, while Kaplan-Meier curve was employed for survival rate analysis. Cox proportional hazard model was used for the risk factors for prognosis of patients with esophageal cancer. Our results indicated reduced levels of volume transfer constant, while increased levels were observed in ADC min , ADC mean , and ADC max following chemoradiotherapy. A negative correlation was determined between ADC min , ADC mean , and ADC max , as well as in the tumor size reduction rate prior to chemoradiotherapy, whereas a positive correlation was uncovered postchemoradiotherapy. Volume transfer constant was positively correlated with tumor size reduction rate both before and after chemoradiotherapy. The 5-year survival rate of patients with esophageal cancer having high ADC min , ADC mean , and ADC max and volume transfer constant before chemoradiotherapy was greater than those with respectively lower values. According to the Cox proportional hazard model, ADC mean , clinical stage, degree of differentiation, and tumor stage were all confirmed as being independent risk factors in regard to the prognosis of patients with EC. The findings of this study provide evidence suggesting that volume transfer constant and apparent diffusion coefficient as being tools allowing for the evaluation of both the short- and long-term efficacies of chemoradiotherapy esophageal cancer treatment.
Powers, Rachel A.; Swanson, Hollister C.; Taracila, Magdalena A.; ...
2014-11-07
β-Lactam resistance in Acinetobacter baumannii presents one of the greatest challenges to contemporary antimicrobial chemotherapy. Much of this resistance to cephalosporins derives from the expression of the class C β-lactamase enzymes, known as Acinetobacter-derived cephalosporinases (ADCs). Currently, β-lactamase inhibitors are structurally similar to β-lactam substrates and are not effective inactivators of this class C cephalosporinase. Herein, two boronic acid transition state inhibitors (BATSIs S02030 and SM23) that are chemically distinct from β-lactams were designed and tested for inhibition of ADC enzymes. BATSIs SM23 and S02030 bind with high affinity to ADC-7, a chromosomal cephalosporinase from Acinetobacter baumannii (K i =more » 21.1 ± 1.9 nM and 44.5 ± 2.2 nM, respectively). The X-ray crystal structures of ADC-7 were determined in both the apo form (1.73 Å resolution) and in complex with S02030 (2.0 Å resolution). In the complex, S02030 makes several canonical interactions: the O1 oxygen of S02030 is bound in the oxyanion hole, and the R1 amide group makes key interactions with conserved residues Asn152 and Gln120. In addition, the carboxylate group of the inhibitor is meant to mimic the C 3/C 4 carboxylate found in β-lactams. The C 3/C 4 carboxylate recognition site in class C enzymes is comprised of Asn346 and Arg349 (AmpC numbering), and these residues are conserved in ADC-7. Interestingly, in the ADC-7/S02030 complex, the inhibitor carboxylate group is observed to interact with Arg340, a residue that distinguishes ADC-7 from the related class C enzyme AmpC. A thermodynamic analysis suggests that ΔH driven compounds may be optimized to generate new lead agents. In conclusion, the ADC-7/BATSI complex provides insight into recognition of non-β-lactam inhibitors by ADC enzymes and offers a starting point for the structure-based optimization of this class of novel β-lactamase inhibitors against a key resistance target.« less
ADCS controllers comparison for small satellitess in Low Earth Orbit
NASA Astrophysics Data System (ADS)
Calvo, Daniel; Laverón-Simavilla, Ana; Lapuerta, Victoria
2016-07-01
Fuzzy logic controllers are flexible and simple, suitable for small satellites Attitude Determination and Control Subsystems (ADCS). In a previous work, a tailored Fuzzy controller was designed for a nanosatellite. Its performance and efficiency were compared with a traditional Proportional Integrative Derivative (PID) controller within the same specific mission. The orbit height varied along the mission from injection at around 380 km down to 200 km height, and the mission required pointing accuracy over the whole time. Due to both, the requirements imposed by such a low orbit, and the limitations in the power available for the attitude control, an efficient ADCS is required. Both methodologies, fuzzy and PID, were fine-tuned using an automated procedure to grant maximum efficiency with fixed performances. The simulations showed that the Fuzzy controller is much more efficient (up to 65% less power required) in single manoeuvres, achieving similar, or even better, precision than the PID. The accuracy and efficiency improvement of the Fuzzy controller increase with orbit height because the environmental disturbances decrease, approaching the ideal scenario. However, the controllers are meant to be used in a vast range of situations and configurations which exceed those used in the calibration process carried out in the previous work. To assess the suitability and performance of both controllers in a wider framework, parametric and statistical methods have been applied using the Monte Carlo technique. Several parameters have been modified randomly at the beginning of each simulation: the moments of inertia of the whole satellite and of the momentum wheel, the residual magnetic dipole and the initial conditions of the test. These parameters have been chosen because they are the main source of uncertainty during the design phase. The variables used for the analysis are the error (critical for science) and the operation cost (which impacts the mission lifetime and outcome). The analysis of the simulations has shown that, in overall, the PID error is over twice the Fuzzy error and the PID cost is over 40% bigger than the Fuzzy cost. This suggests that a Fuzzy controller may be a better solution in a wider range of configurations than other classical solutions like the PID.
Zhang, Guangwen; Wang, Shuangshuang; Wen, Didi; Zhang, Jing; Wei, Xiaocheng; Ma, Wanling; Zhao, Weiwei; Wang, Mian; Wu, Guosheng; Zhang, Jinsong
2016-12-09
Water molecular diffusion in vivo tissue is much more complicated. We aimed to compare non-Gaussian diffusion models of diffusion-weighted imaging (DWI) including intra-voxel incoherent motion (IVIM), stretched-exponential model (SEM) and Gaussian diffusion model at 3.0 T MRI in patients with rectal cancer, and to determine the optimal model for investigating the water diffusion properties and characterization of rectal carcinoma. Fifty-nine consecutive patients with pathologically confirmed rectal adenocarcinoma underwent DWI with 16 b-values at a 3.0 T MRI system. DWI signals were fitted to the mono-exponential and non-Gaussian diffusion models (IVIM-mono, IVIM-bi and SEM) on primary tumor and adjacent normal rectal tissue. Parameters of standard apparent diffusion coefficient (ADC), slow- and fast-ADC, fraction of fast ADC (f), α value and distributed diffusion coefficient (DDC) were generated and compared between the tumor and normal tissues. The SEM exhibited the best fitting results of actual DWI signal in rectal cancer and the normal rectal wall (R 2 = 0.998, 0.999 respectively). The DDC achieved relatively high area under the curve (AUC = 0.980) in differentiating tumor from normal rectal wall. Non-Gaussian diffusion models could assess tissue properties more accurately than the ADC derived Gaussian diffusion model. SEM may be used as a potential optimal model for characterization of rectal cancer.
NASA Astrophysics Data System (ADS)
Gao, Shanghua; Xue, Bing
2017-04-01
The dynamic range of the currently most widely used 24-bit seismic data acquisition devices is 10-20 dB lower than that of broadband seismometers, and this can affect the completeness of seismic waveform recordings under certain conditions. However, this problem is not easy to solve because of the lack of analog to digital converter (ADC) chips with more than 24 bits in the market. So the key difficulties for higher-resolution data acquisition devices lie in achieving more than 24-bit ADC circuit. In the paper, we propose a method in which an adder, an integrator, a digital to analog converter chip, a field-programmable gate array, and an existing low-resolution ADC chip are used to build a third-order 16-bit oversampling delta-sigma modulator. This modulator is equipped with a digital decimation filter, thus forming a complete analog to digital converting circuit. Experimental results show that, within the 0.1-40 Hz frequency range, the circuit board's dynamic range reaches 158.2 dB, its resolution reaches 25.99 dB, and its linearity error is below 2.5 ppm, which is better than what is achieved by the commercial 24-bit ADC chips ADS1281 and CS5371. This demonstrates that the proposed method may alleviate or even solve the amplitude-limitation problem that broadband observation systems so commonly have to face during strong earthquakes.
NASA Astrophysics Data System (ADS)
Xue, F.; Gao, W.; Duan, Y.; Zheng, R.; Hu, Y.
2018-02-01
This paper presents a 12-bit pipelined successive approximation register (SAR) ADC for CZT-based hard X-ray Imager. The proposed ADC is comprised of a first-stage 6-bit SAR-based Multiplying Digital Analog Converter (MDAC) and a second-stage 8-bit SAR ADC. A novel MDAC architecture using Vcm-based Switching method is employed to maximize the energy efficiency and improve the linearity of the ADC. Moreover, the unit-capacitor array instead of the binary-weighted capacitor array is adopted to improve the conversion speed and linearity of the ADC in the first-stage MDAC. In addition, a new layout design method for the binary-weighted capacitor array is proposed to reduce the capacitor mismatches and make the routing become easier and less-time-consuming. Finally, several radiation-hardened-by-design technologies are adopted in the layout design against space radiation effects. The prototype chip was fabricated in 0.18 μm mixed-signal 1.8V/3.3V process and operated at 1.8 V supply. The chip occupies a core area of only 0.58 mm2. The proposed pipelined SAR ADC achieves a peak signal-to-noise-and-distortion ratio (SNDR) of 66.7 dB and a peak spurious-free dynamic range (SFDR) of 78.6 dB at 10 MS/s sampling rate and consumes 10 mW. The figure of merit (FOM) of the proposed ADC is 0.56 pJ/conversion-step.
López-Larrubia, Pilar; Cauli, Omar
2011-03-15
Diffusion-weighted imaging (DWI) allows the assessment of the water apparent diffusion coefficient (ADC), a measure of tissue water diffusivity which is altered during different pathological conditions such as cerebral oedema. By means of DWI, we repeatedly measured in the same rats apparent diffusion coefficient ADC in different brain areas (motor cortex (MCx), somato-sensory cortex (SCx), caudate-putamen (CPu), hippocampus (Hip), mesencephalic reticular formation (RF), corpus callosum (CC) and cerebellum (Cb)) after 1 week, 4 and 12 weeks of lead acetate exposure via drinking water (50 or 500 ppm). After 12 weeks of lead exposure rats received albumin-Evans blue complex administration and were sacrificed 1h later. Blood-brain barrier permeability and water tissue content were determined in order to evaluate their relationship with ADC changes. Chronic exposure to lead acetate (500 ppm) for 4 weeks increased ADC values in Hip, RF and Cb but no in other brain areas. After 12 weeks of lead acetate exposure at 500 ppm ADC is significantly increased also in CPu and CC. Brain areas displaying high ADC values after lead exposure showed also an increased water content and increased BBB permeability to Evans blue-albumin complex. Exposure to 50 ppm for 12 weeks increased ADC values and BBB permeability in the RF and Cb. In summary, chronic lead exposure induces cerebral oedema in the adult brain depending on the brain area and the dose of exposure. RF and Cb appeared the most sensitive brain areas whereas cerebral cortex appears resistant to lead-induced cerebral oedema. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Horvat, Joao V; Durando, Manuela; Milans, Soledad; Patil, Sujata; Massler, Jessica; Gibbons, Girard; Giri, Dilip; Pinker, Katja; Morris, Elizabeth A; Thakur, Sunitha B
2018-06-01
To investigate the impact of background parenchymal enhancement (BPE), amount of fibroglandular tissue (FGT) and menopausal status on apparent diffusion coefficient (ADC) values in differentiation between malignant and benign lesions. In this HIPAA-compliant study, mean ADC values of 218 malignant and 130 benign lesions from 288 patients were retrospectively evaluated. The differences in mean ADC values between benign and malignant lesions were calculated within groups stratified by BPE level (high/low), amount of FGT (dense/non-dense) and menopausal status (premenopausal/postmenopausal). Sensitivities and specificities for distinguishing malignant from benign lesions within different groups were compared for statistical significance. The mean ADC value for malignant lesions was significantly lower compared to that for benign lesions (1.07±0.21 x 10 -3 mm 2 /s vs. 1.53±0.26 x 10 -3 mm 2 /s) (p<0.0001). Using the optimal cut-off point of 1.30 x 10 -3 mm 2 /s, an area under the curve of 0.918 was obtained, with sensitivity and specificity both of 87 %. There was no statistically significant difference in sensitivities and specificities of ADC values between different groups stratified by BPE level, amount of FGT or menopausal status. Differentiation between benign and malignant lesions on ADC values is not significantly affected by BPE level, amount of FGT or menopausal status. • ADC allows differentiation between benign and malignant lesions. • ADC is useful for breast cancer diagnosis despite different patient characteristics. • BPE, FGT or menopause do not significantly affect sensitivity and specificity.
SM-4 computer and CAMAC equipment in automating a ROMS-2A mass spectrometer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bulgakov, R.Sh.; Gafurov, R.A.; Safin, D.N.
1988-05-01
A data acquisition system was developed which provides for measuring mass peaks on three parameters as well as measuring working parameters. The computer memory stores 40 kHz signals, with an ADC cycle time of 10 microsec. A structural diagram is given together with upgrades made in the CAMAC apparatus to improve the speed and extend the application. Working parameters such as the pressures in pipes and the temperature in the test zone can be monitored by splitting the measurements into two cycles alternating with a controlled frequency: gas composition and technological parameter measurement.
Ghosts, Meaning, and Faith: After-Death Communications in Bereavement Narratives
ERIC Educational Resources Information Center
Kwilecki, Susan
2011-01-01
After-death communications (ADCs) are reported encounters with a deceased loved one, a contemporary type of ghost experience heralded as therapeutic in coping with bereavement. Pertinent literature generally illustrates the healing power of ADCs with brief, self-contained episodes. The functions of ADCs over the course of grief need exploration.…
2015-01-01
Antibody–drug conjugates (ADCs) combine the specificity of antibodies with the potency of small molecules to create targeted drugs. Despite the simplicity of this concept, generation of clinically successful ADCs has been very difficult. Over the past several decades, scientists have learned a great deal about the constraints on antibodies, linkers, and drugs as they relate to successful construction of ADCs. Once these components are in hand, most ADCs are prepared by nonspecific modification of antibody lysine or cysteine residues with drug-linker reagents, which results in heterogeneous product mixtures that cannot be further purified. With advances in the fields of bioorthogonal chemistry and protein engineering, there is growing interest in producing ADCs by site-specific conjugation to the antibody, yielding more homogeneous products that have demonstrated benefits over their heterogeneous counterparts in vivo. Here, we chronicle the development of a multitude of site-specific conjugation strategies for assembly of ADCs and provide a comprehensive account of key advances and their roots in the fields of bioorthogonal chemistry and protein engineering. PMID:25494884
Agarwal, Paresh; Bertozzi, Carolyn R
2015-02-18
Antibody-drug conjugates (ADCs) combine the specificity of antibodies with the potency of small molecules to create targeted drugs. Despite the simplicity of this concept, generation of clinically successful ADCs has been very difficult. Over the past several decades, scientists have learned a great deal about the constraints on antibodies, linkers, and drugs as they relate to successful construction of ADCs. Once these components are in hand, most ADCs are prepared by nonspecific modification of antibody lysine or cysteine residues with drug-linker reagents, which results in heterogeneous product mixtures that cannot be further purified. With advances in the fields of bioorthogonal chemistry and protein engineering, there is growing interest in producing ADCs by site-specific conjugation to the antibody, yielding more homogeneous products that have demonstrated benefits over their heterogeneous counterparts in vivo. Here, we chronicle the development of a multitude of site-specific conjugation strategies for assembly of ADCs and provide a comprehensive account of key advances and their roots in the fields of bioorthogonal chemistry and protein engineering.
Byun, Jong Hyuk; Jung, Il Hyo
2018-04-14
Antibody drug conjugates (ADCs)are one of the most recently developed chemotherapeutics to treat some types of tumor cells. They consist of monoclonal antibodies (mAbs), linkers, and potent cytotoxic drugs. Unlike common chemotherapies, ADCs combine selectively with a target at the surface of the tumor cell, and a potent cytotoxic drug (payload) effectively prevents microtubule polymerization. In this work, we construct an ADC model that considers both the target of antibodies and the receptor (tubulin) of the cytotoxic payloads. The model is simulated with brentuximab vedotin, one of ADCs, and used to investigate the pharmacokinetic (PK) characteristics of ADCs in vivo. It also predicts area under the curve (AUC) of ADCs and the payloads by identifying the half-life. The results show that dynamical behaviors fairly coincide with the observed data and half-life and capture AUC. Thus, the model can be used for estimating some parameters, fitting experimental observations, predicting AUC, and exploring various dynamical behaviors of the target and the receptor. Copyright © 2018 Elsevier Ltd. All rights reserved.
Evaluation of Multi-Channel ADCs for Gamma-Ray Spectroscopy
NASA Astrophysics Data System (ADS)
Tan, Hui; Hennig, Wolfgang; Walby, Mark D.; Breus, Dimitry; Harris, Jackson
2013-04-01
As nuclear physicists increasingly design large scale experiments with hundreds or thousands of detector channels, there are growing needs for high density readout electronics with good timing and energy resolution that at the same time offer lower cost per channel compared to existing commercial solutions. Recent improvements in the design of commercial analog to digital converters (ADCs) have resulted in a variety of multi-channel ADCs that are natural choice for designing such high density readout modules. However, multi-channel ADCs typically are designed for medical imaging/ultrasound applications and therefore are not rated for their spectroscopic characteristics. In this work, we evaluated the gamma-ray spectroscopic performance of several multi-channel ADCs, including their energy resolution, nonlinearity, and timing resolution. Some of these ADCs demonstrated excellent energy resolution, 2.66% FWHM at 662 keV with a LaBr3 or 1.78 keV FWHM at 1332.5 keV with a high purity germanium (HPGe) detector, and sub-nanosecond timing resolution with LaBr 3. We present results from these measurements to illustrate their suitability for gamma-ray spectroscopy.
Miyagi, Ryo; Sakai, Toshinori; Yamabe, Eiko; Yoshioka, Hiroshi
2015-06-27
Diffusion weighted imaging (DWI) and diffusion tensor imaging (DTI) are widely used in the evaluation of the central nervous system and recently have been reported as a potential tool for diagnosis of the peripheral nerve or the lumbar nerve entrapment. The purpose of this study was to evaluate consecutive changes in apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values of normal lumbar nerve roots from the junction of the dura mater. The lumbar spinal nerves were examined in 6 male healthy volunteers (mean age, 35 years) with no experiences of sciatica, with a 3.0-T MR unit using a five-element phased-array surface coil. DTI was performed with the following imaging parameters: 11084.6/73.7 ms for TR/TE; b-value, 800 s/mm2; MPG, 33 directions; slice thickness, 1.5 mm; and total scan time, 7 min 35 s. ADC and FA values at all consecutive points along the L4, L5 and S1 nerves were quantified on every 1.5 mm slice from the junction of the dura mater using short fiber tracking. ADC values of all L4, 5, and S1 nerve roots decreased linearly up to 15 mm from the dura junction and was constant distally afterward. ADC values in the proximal portion demonstrated S1 > L5 > L4 (p < 0.05). On the other hand, FA values increased linearly up to 15 mm from the dura junction, and was constant distally afterward. FA values in the proximal portion showed L4 > L5 > S1 (p < 0.05). Our study demonstrated that ADC and FA values of each L4, 5, and S1 at the proximal portion from the junction of the dura matter changed linearly. It would be useful to know the normal profile of DTI values by location of each nerve root so that we can detect subtle abnormalities in each nerve root.
Toslak, Iclal Erdem; Cekic, Bulent; Turk, Aysen; Eraslan, Ali; Parlak, A Eda
2017-10-10
Our aims were to determine the feasibility of diffusion-weighted magnetic resonance imaging (DWI) in the detection of bone marrow edema (BME) and explore the apparent diffusion coefficient (ADC) alterations in patients with osteitis pubis (OP). 42 consecutive patients clinically suspected to have athletic pubalgia and 31 control subjects were enrolled in the study. All subjects underwent diagnostic focused magnetic resonance imaging (MRI) and DWI at b values of 0 and 600 s/mm 2 . Two radiologists reviewed the images for the presence of active OP. The presence of subchondral BME and contrast enhancement were considered to indicate active OP. ADC values were measured from public bodies of both groups. DWI results were correlated with routine MRI findings. Receiver-operating-characteristic curves were formed. Cut-off values for ADC, sensitivity and specificity values were measured. 36/42 (85%) of the cases had BME/enhancement on routine MRIs and identified as active OP. ADC measurements of the patients were greater than the controls (P < 0.05). For the optimal cut-off values DWI showed sensitivity and specificity values of 97.3%, and 90.3%, for the right, and 97.1%, and 96.7% for the left side, respectively (Area under the curve 0.965 and 0.973). Intra-and inter-rater reliability for readers were substantial-perfect for all sessions. DWI is fast, accurate, and highly reproducible technique for the detection of BME in patients with active OP. It allows distinct bone marrow contrast without the use of gadolinium contrast, increases visual perception of active lesions, gives objective information by quantifying the diffusion coefficients, thus increase diagnostic confidence. We suggest the use of DWI as a cost-effective adjunctive tool for the diagnosis of active OP particularly in early cases and inconclusive diagnostic MRI. Future studies are necessary to determine the utility of DWI to evaluate severity of the disease and treatment response before returning athletes to play.
Bongers, Andre; Hau, Eric; Shen, Han
2018-01-04
To investigate a novel alternative diffusion-weighted imaging (DWI) approach using oscillating gradients preparation (OGSE) to obtain much shorter effective diffusion times (Δ eff ) for tumor response monitoring by apparent diffusion coefficient (ADC) mapping in a glioblastoma mouse model. Twenty-four BALB/c nude mice inoculated with U87 glioblastoma cells were randomized into a control group and an irradiation group, which underwent a 15-day fractioned radiation therapy (RT) course with 2 Gy/d. Therapy response was assessed by mapping of ADCs at 6 time points using an in-house implementation of a cos-OGSE DWI sequence with Δ eff = 1.25 ms and compared with a standard pulsed gradient DWI protocol (PGSE) with typical clinical diffusion time Δ eff = 18 ms. Longitudinal ADC changes in tumor and contralateral white matter (WM) were statistically assessed using repeated-measures analysis of variance and post hoc (Sidak) testing. On short Δ eff OGSE maps tumor ADC was generally 30%-50% higher than in surrounding WM. Areas correlated well with histology. Tumor identification was generally more difficult on PGSE maps owing to nonsignificant WM/tumor contrast. During RT, OGSE maps also showed significant tumor ADC increase (approximately 15%) in response to radiation, consistently seen after 14-Gy RT dose. The clinical reference (PGSE) showed lower sensitivity to radiation changes, and no significant response across the radiation group and time course could be detected. Our short Δ eff DWI method using OGSE better reflected histologically defined tumor areas and enabled more consistent and earlier detection of microstructural radiation changes than conventional methods. Oscillating gradients preparation offers significant potential as a robust microstructural RT response biomarker, potentially helping to shift important therapy decisions to earlier stages in the RT time course. Copyright © 2018 Elsevier Inc. All rights reserved.
Rechichi, Gilda; Galimberti, Stefania; Signorelli, Mauro; Franzesi, Cammillo Talei; Perego, Patrizia; Valsecchi, Maria Grazia; Sironi, Sandro
2011-07-01
The objective of our study was to investigate whether apparent diffusion coefficient (ADC) values of endometrial cancer differ from those of normal endometrium and myometrium and whether they vary according to histologic tumor grade, the depth of myometrial invasion, or lymph node status. Seventy patients with histologically proved endometrial cancer and 36 control subjects with normal endometrium were enrolled in this prospective study. T2-weighted, dynamic T1-weighted, and diffusion-weighted images with b values of 0 and 1000 s/mm(2) were obtained of all patients. The ADC values of endometrial cancer, normal endometrium, and normal myometrium were recorded. Tumor grade, the depth of myometrial invasion, and lymph node status were assessed at postoperative histopathologic analysis. The mean (± SD) ADC value (10(-3) mm(2)/s) of endometrial cancer (0.77 ± 0.12) was significantly lower than that of normal endometrium (1.31 ± 0.11, p < 0.0001) and normal myometrium (1.52 ± 0.21, p < 0.0001), with no overlap between the two former distributions. There was no significant difference between ADC values of endometrial cancer tissue in patients with tumor grade 1 (0.79 ± 0.08, n = 14), grade 2 (0.76 ± 0.14, n = 40), or grade 3 (0.75 ± 0.12, n = 16) (p = 0.67); in patients with deep (0.77 ± 0.13, n = 18) and those with superficial (0.76 ± 0.12, n = 52) myometrial invasion (p = 0.87); and in patients with (0.78 ± 0.10, n = 6) and those without (0.75 ± 0.14, n = 39) lymph node metastases (p = 0.64). ADC values allow normal endometrium to be differentiated from endometrial carcinoma; however, they do not correlate with histologic tumor grade, the depth of myometrial invasion, or whether lymph node metastases are present.
Faletti, Riccardo; Cassinis, Maria Carla; Gatti, Marco; Giglio, Jacopo; Guarnaccia, Carla; Messina, Marina; Bergamasco, Laura; Fonio, Paolo
2016-03-01
To assess reliability of diffusion-weighted magnetic resonance imaging (DW-MRI) in the management of acute pyelonephritis (APN) foci in transplanted kidneys. In the 2012-2014 period, 24 kidney-transplanted patients underwent MR screening for clinical suspicion of APN. Two readers independently analyzed all images, establishing presence and location of APN foci. The 22 patients who were positive at the MR exam constituted the study population. For each patient the apparent diffusion coefficient (ADC) was measured in the APN foci and in three sites of the healthy parenchyma (case-control comparison). The data were matched to the laboratory measurements for white blood cell, C-reactive protein, and serum creatinine. Forty-six APN foci were found in 22/24 patients. At the acute stage, the difference in ADC between healthy parenchyma and APN foci was significant (2.06 ± 0.16 vs. 1.43 ± 0.32 × 10(-3) mm(2)/s; p < 0.0001). The performance of ADC as APN indicator was tested by the receiving operating characteristics (ROC) curve: the area under curve AUC = 0.99 witnessed an excellent discriminatory ability, with threshold APN/normal parenchyma 1.9 × 10(-3) mm(2)/s. At the 1-month follow-up 43/46 APN foci were no longer visible, with ADC values significantly higher than at the acute stage; all laboratory data were physiological, with WBC significantly reduced from the acute phase (5.2 ± 1.6 × 10(9)/L vs. 10.6 ± 4.8 × 10(9)/L; p < 0.0001). The other 3 patients underwent further therapy and exams, including a third MR. DW-MRI with ADC measurement seems to be a reliable tool in diagnosing and monitoring APN foci in transplanted kidneys, with clinical impact on patient management.
Ikink, Marlijne E; Voogt, Marianne J; van den Bosch, Maurice A A J; Nijenhuis, Robbert J; Keserci, Bilgin; Kim, Young-sun; Vincken, Koen L; Bartels, Lambertus W
2014-09-01
To assess the value of diffusion-weighted magnetic resonance imaging (DWI) and apparent diffusion coefficient (ADC) mapping using different b-value combinations for treatment evaluation after magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) of uterine fibroids. Fifty-six patients with 67 uterine fibroids were treated with volumetric MR-HIFU. Pre-treatment and post-treatment images were obtained using contrast-enhanced T1-weighted MRI (CE-T1WI) and DWI using b = 0, 200, 400, 600, 800 s/mm(2). ADC maps were generated using subsets of b-values to investigate the effects of tissue ablation on water diffusion and perfusion in fibroids treated with MR-HIFU. Four combinations of b-values were used: (1) all b-values; (2) b = 0, 200 s/mm(2); (3) b = 400, 600, 800 s/mm(2); and (4) b = 0, 800 s/mm(2). Using the lowest b-values (0 and 200 s/mm(2)), the mean ADC value in the ablated tissue reduced significantly (p < 0.001) compared with baseline. Calculating the ADC value with the highest b-values (400, 600, 800 s/mm(2)), the ADC increased significantly (p < 0.001) post-treatment. ADC maps calculated with the lowest b-values resulted in the best visual agreement of non-perfused fibroid tissue detected on CE images. Other b-value combinations and normal myometrium showed no difference in ADC after MR-HIFU treatment. A decrease in contrast agent uptake within the ablated region on CE-T1WI was correlated to a significantly decreased ADC when b = 0 and 200 s/mm(2) were used. DWI could be useful for treatment evaluation after MR-HIFU of uterine fibroids. The ADC in fibroid tissue is influenced by the choice of b- values. Low b-values seem the best choice to emphasise perfusion effects after MR-HIFU.
García Santos, J M; Ordóñez González, C; Torres del Río, S
2009-01-01
To analyze the effects of age, sex, and b value on the apparent diffusion coefficient (ADC) in brain areas affected by neurodegenerative diseases. We studied the ADC of the genu and splenium of the corpus callosum and of the hippocampus in normal patients using diffusion magnetic resonance imaging (dMRI) with b1,000 s/mm2 and b3,000 s/mm2. We calculated the differences between the ADC (diffusion differential [DD]) with b1,000 and with b3,000 for each region. Patients were classified into the following age groups (
Liu, Xiaohang; Zhou, Liangping; Peng, Weijun; Wang, He; Zhang, Yong
2015-10-01
To compare stretched-exponential and monoexponential model diffusion-weighted imaging (DWI) in prostate cancer and normal tissues. Twenty-seven patients with prostate cancer underwent DWI exam using b-values of 0, 500, 1000, and 2000 s/mm(2) . The distributed diffusion coefficients (DDC) and α values of prostate cancer and normal tissues were obtained with stretched-exponential model and apparent diffusion coefficient (ADC) values using monoexponential model. The ADC, DDC (both in 10(-3) mm(2)/s), and α values (range, 0-1) were compared among different prostate tissues. The ADC and DDC were also compared and correlated in each tissue, and the standardized differences between DDC and ADC were compared among different tissues. Data were obtained for 31 cancers, 36 normal peripheral zone (PZ) and 26 normal central gland (CG) tissues. The ADC (0.71 ± 0.12), DDC (0.60 ± 0.18), and α value (0.64 ± 0.05) of tumor were all significantly lower than those of the normal PZ (1.41 ± 0.22, 1.47 ± 0.20, and 0.85 ± 0.09) and CG (1.25 ± 0.14, 1.32 ± 0.13, and 0.82 ± 0.06) (all P < 0.05). ADC was significantly higher than DDC in cancer, but lower than DDC in the PZ and CG (all P < 0.05). The ADC and DDC were strongly correlated (R(2) = 0.99, 0.98, 0.99, respectively, all P < 0.05) in all the tissue, and standardized difference between ADC and DDC of cancer was slight but significantly higher than that in normal tissue. The stretched-exponential model DWI provides more parameters for distinguishing prostate cancer and normal tissue and reveals slight differences between DDC and ADC values. © 2015 Wiley Periodicals, Inc.
Meyer, Hans-Jonas; Emmer, Alexander; Kornhuber, Malte; Surov, Alexey
2018-05-01
MRI is widely used in several muscle disorders. Diffusion-weighted imaging (DWI) is an emergent imaging modality sensitive to microstructural alterations in tissue. The apparent diffusion coefficient (ADC) is used to quantify the random motion of water molecules. Electromyography (EMG) is a clinically used diagnostic tool in myositis. The aim of this study was to elucidate possible associations between ADC values and EMG findings in myositis patients. Seven patients (eight investigated muscles) with myositis (mean age 51.43 ± 19 years) were included in this study. The diagnosis was confirmed by histopathology in every case. DWI was obtained with a 1.5-T scanner using two b-values 0 and 1000 s/mm². In all patients, a needle electromyography (EMG) was performed within 3 days to the MRI. The following EMG parameters were studied: motor unit action potential (MUAP) amplitudes and durations, as well as pathological spontaneous activity. Spearman's correlation coefficient was used to analyze associations between investigated parameters. The estimated mean ADC mean value was 1.51 ± 0.29 × 10 -3 mm²/s, mean ADC min was 1.28 ± 0.27 × 10 -3 mm²/s, and mean ADC max was 1.73 ± 0.28 × 10 -3 mm²/s. Correlation analysis identified significant associations between ADC mean and duration of the MUAP (p = .78 P = .0279) and between ADC min and duration of the MUAP (p = .85, P = .01). There were no significant differences according to pathological spontaneous activity. ADC mean and ADC min showed strong positive correlations with the duration of the MUAP in myositis patients. Both modalities might similarly reflect muscle fiber loss in myositis patients.
Soyer, Philippe; Corno, Lucie; Boudiaf, Mourad; Aout, Mounir; Sirol, Marc; Placé, Vinciane; Duchat, Florent; Guerrache, Youcef; Fargeaudou, Yann; Vicaut, Eric; Pocard, Marc; Hamzi, Lounis
2011-11-01
To test interobserver variability of ADC measurements and compare the diagnostic performances of free-breathing diffusion-weighted (FBDW) with that of T2-weighted FSE (T2WFSE) MR imaging for differentiating between cavernous hemangiomas and untreated malignant hepatic neoplasms. Thirty-five patients with cavernous hemangiomas and 35 with untreated hepatic malignant neoplasms had FBDW and T2WFSE MR imaging. Hepatic lesions were characterized with ADC measurement and visual evaluation. Interobserver agreement for ADC measurement was calculated. Association between ADC value and lesion type was assessed using univariate analysis. Sensitivity, specificity and accuracy of ADC values and visual evaluation of MR images for the diagnosis of untreated malignant hepatic neoplasm were compared. ADC measurements showed excellent interobserver correlation (intraclass correlation coefficient=0.980). Malignant neoplasms had lower ADC values than hemangiomas for the two observers (1.11×10(-3) mm2/s±.21×10(-3) vs. 1.77×10(-3) mm2/s±.29×10(-3) for observer 1 and 1.11×10(-3) mm2/s±.19×10(-3) vs. 1.79×10(-3) mm2/s±.32×10(-3) for observer 2) and univariate analysis found significant correlations between lesion type and ADC values. Depending on ADC threshold value, accuracy for the diagnosis of malignant neoplasm varied from 82.9% to 94.3%. Using visual evaluation, FBDW showed better specificity and accuracy than T2WFSE MR images for the diagnosis of malignant neoplasm (97.1% vs. 77.1% and 94.3% vs. 62.9%, respectively). FBDW imaging provides reproducible quantitative information and surpasses the value of T2WFSE MR imaging for differentiating between cavernous hemangiomas and untreated malignant hepatic neoplasms. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Geith, Tobias; Schmidt, Gerwin; Biffar, Andreas; Dietrich, Olaf; Duerr, Hans Roland; Reiser, Maximilian; Baur-Melnyk, Andrea
2014-09-01
The purpose of our study was to determine the optimum combination of b values for calculating the apparent diffusion coefficient (ADC) using a diffusion-weighted (DW) single-shot turbo spin-echo (TSE) sequence in the differentiation between acute benign and malignant vertebral body fractures. Twenty-six patients with osteoporotic (mean age, 69 years; range, 31.5-86.2 years) and 20 patients with malignant vertebral fractures (mean age, 63.4 years; range, 24.7-86.4 years) were studied. T1-weighted, STIR, and T2-weighted sequences were acquired at 1.5 T. A DW single-shot TSE sequence at different b values (100, 250, 400, and 600 s/mm(2)) was applied. On the DW images for each evaluated fracture, an ROI was manually adapted to the area of hyperintense signal intensity on STIR-hypointense signal on T1-weighted images. For each ROI, nine different combinations of two, three, and four b values were used to calculate the ADC using a least-squares algorithm. The Student t test and Mann-Whitney U test were used to determine significant differences between benign and malignant fractures. An ROC analysis and the Youden index were used to determine cutoff values for assessment of the highest sensitivity and specificity for the different ADC values. The positive (PPV) and negative predictive values (NPV) were also determined. All calculated ADCs (except the combination of b = 400 s/mm(2) and b = 600 s/mm(2)) showed statistically significant differences between benign and malignant vertebral body fractures, with benign fractures having higher ADCs than malignant ones. The use of higher b values resulted in lower ADCs than those calculated with low b values. The highest AUC (0.85) showed the ADCs calculated with b = 100 and 400 s/mm(2), and the second highest AUC (0.829) showed the ADCs calculated with b = 100, 250, and 400 s/mm(2). The Youden index with equal weight given to sensitivity and specificity suggests use of an ADC calculated with b = 100, 250, and 400 s/mm(2) (cutoff ADC, < 1.7 × 10(-3) mm(2)/s) to best diagnose malignancy (sensitivity, 85%; specificity, 84.6%; PPV, 81.0%; NPV, 88.0%). ADCs calculated with a combination of low to intermediate b values (b = 100, 250, and 400 s/mm(2)) provide the best diagnostic performance of a DW single-shot TSE sequence to differentiate acute benign and malignant vertebral body fractures.
Chen, Xin; Qin, Lei; Pan, Dan; Huang, Yanqi; Yan, Lifen; Wang, Guangyi; Liu, Yubao; Liang, Changhong; Liu, Zaiyi
2014-04-01
To prospectively compare the reproducibility of normal liver apparent diffusion coefficient (ADC) measurements by using different respiratory motion compensation techniques with multiple breath-hold (MBH), free-breathing (FB), respiratory-triggered (RT), and navigator-triggered (NT) diffusion-weighted (DW) imaging and to compare the ADCs at different liver anatomic locations. The study protocol was approved by the institutional review board, and written informed consent was obtained from each participant. Thirty-nine volunteers underwent liver DW imaging twice. Imaging was performed with a 1.5-T MR imager with MBH, FB, RT, and NT techniques (b = 0, 100, and 500 sec/mm(2)). Three representative sections--superior, central, and inferior--were selected on left and right liver lobes, respectively. On each selected section, three regions of interest were drawn, and ADCs were measured. Analysis of variance was used to assess ADCs among the four techniques and various anatomic locations. Reproducibility of ADCs was assessed with the Bland-Altman method. ADCs obtained with MBH (range: right lobe, [1.641-1.662] × 10(-3)mm(2)/sec; left lobe, [2.034-2.054] ×10(-3)mm(2)/sec) were higher than those obtained with FB (right, [1.349-1.391] ×10(-3)mm(2)/sec; left, [1.630-1.700] ×10(-3)mm(2)/sec), RT (right, [1.439-1.455] ×10(-3)mm(2)/sec; left, [1.720-1.755] ×10(-3)mm(2)/sec), or NT (right, [1.387-1.400] ×10(-3)mm(2)/sec; left, [1.661-1.736] ×10(-3)mm(2)/sec) techniques (P < .001); however, no significant difference was observed between ADCs obtained with FB, RT, and NT techniques (P = .130 to P >.99). ADCs showed a trend to decrease moving from left to right. Reproducibility in the left liver lobe was inferior to that in the right, and the central middle segment in the right lobe had the most reproducible ADC. Statistical differences in ADCs were observed in the left-right direction in the right lobe (P < .001), but they were not observed in the superior-inferior direction (P = .144-.450). However, in the left liver lobe, statistical differences existed in both directions (P = .001 to P = .016 in the left-right direction, P < .001 in the superior-inferior direction). Both anatomic location and DW imaging technique influence liver ADC measurements and their reproducibility. FB DW imaging is recommended for liver DW imaging because of its good reproducibility and shorter acquisition time compared with that of MBH, RT, and NT techniques. RSNA, 2014
DOE Office of Scientific and Technical Information (OSTI.GOV)
McKisson, John
The source code for the Java Data Acquisition suite provides interfaces to the JLab built USB FPGA ADC across a LAN network. Each jDaq node provides ListMode data from JLab built detector systems and readouts.
Wang, Tingting; Wu, Xiangru; Cui, Yanfen; Chu, Caiting; Ren, Gang; Li, Wenhua
2014-11-29
Benign and malignant bone tumors can present similar imaging features. This study aims to evaluate the significance of apparent diffusion coefficients (ADC) in differentiating between benign and malignant bone tumors. A total of 187 patients with 198 bone masses underwent diffusion-weighted (DW) magnetic resonance (MR) imaging. The ADC values in the solid components of the bone masses were assessed. Statistical differences between the mean ADC values in the different tumor types were determined by Student's t-test. Histological analysis showed that 84/198 (42.4%) of the bone masses were benign and 114/198 (57.6%) were malignant. There was a significant difference between the mean ADC values in the benign and malignant bone lesions (P<0.05). However, no significant difference was found in the mean ADC value between non-ossifying fibromas, osteofibrous dysplasia, and malignant bone tumors. When an ADC cutoff value≥1.10×10(-3) mm2/s was applied, malignant bone lesions were excluded with a sensitivity of 89.7%, a specificity of 84.5%, a positive predictive value of 82.6%, and a negative predictive value of 95.3%. The combination of DW imaging with ADC quantification and T2-weighted signal characteristics of the solid components in lesions can facilitate differentiation between benign and malignant bone tumors.
Xie, Weilong; Perry, Gregory; Martin, C Joe; Shim, Youn-Seb; Navabi, Alireza; Pauls, K Peter
2017-07-01
Common beans (Phaseolus vulgaris) are excellent sources of dietary folates, but different varieties contain different amounts of these compounds. Genes coding for dihydroneopterin aldolase (DHNA) and aminodeoxychorismate synthase (ADCS) of the folate synthesis pathway were characterized by PCR amplification, BAC clone sequencing, and whole genome sequencing. All DHNA and ADCS genes in the Mesoamerican cultivar OAC Rex were isolated and compared with those genes in the genome of Andean genotype G19833. Both genotypes have two functional DHNA genes and one pseudo gene. PvDHNA1 and PvDHNA2 proteins have similar secondary structures and conserved residues as DHNA homologs in Staphylococcus aureus and Arabidopsis. Sequence analysis and synteny mapping indicated that PvDHNA1 might be a duplicated and transposed copy of PvDHNA2. There is only one ADCS gene (PvADCS) identified in the bean genome and it is identical in OAC Rex and G19833. PvADCS has the conserved motifs required for catalytic activity similar to other plant ADCS homologs. DHNA and ADCS gene-specific markers were developed, mapped, and compared to their physical locations on chromosomes 1 and 7, respectively. The gene-specific markers developed in this study should be useful for detection and selection of varieties with enhanced folate contents in bean breeding programs.
Zhong, Xiu; Qiu, Shijun
2015-06-01
To investigate the effect of exercise load on apparent diffusion coefficient (ADC) and fractional anisotropy (FA) of normal lumbar intervertebral discs in magnetic resonance (MR) diffusion tensor imaging (DTI). Thirty healthy volunteers (24 males and 6 females, aged 19 to 25 years) underwent examinations with MR T2WI and DTI of the lumbar intervertebral discs before and after exercise load. Pfirrmann grading was evaluated with T2WI, and the B0 map, ADC map and FA map were reconstructed based on the DTI data to investigate the changes in ADC and FA after exercise. Of the 30 volunteers (150 intervertebral discs) receiving the examination, 27 with discs of Pfirrminn grade II were included for analysis. In these 27 volunteers, the average ADC and FA before exercise were (1.99 ± 0.18)×10⁻³ mm²/s and 0.155∓0.059, respectively. After exercise, ADC was lowered significantly to (1.93 ± 0.17)×10⁻³ mm²/s (P<0.05) and FA increased slightly to 0.1623 ± 0.017 (P>0.05). DTI allows quantitatively analysis of the changes in water molecular diffusion and anisotropy of the lumbar intervertebral discs after exercise load, which can cause a decreased ADC and a increased FA value, and the change of ADC is more sensitive to exercise load.
High frequency signal acquisition and control system based on DSP+FPGA
NASA Astrophysics Data System (ADS)
Liu, Xiao-qi; Zhang, Da-zhi; Yin, Ya-dong
2017-10-01
This paper introduces a design and implementation of high frequency signal acquisition and control system based on DSP + FPGA. The system supports internal/external clock and internal/external trigger sampling. It has a maximum sampling rate of 400MBPS and has a 1.4GHz input bandwidth for the ADC. Data can be collected continuously or periodically in systems and they are stored in DDR2. At the same time, the system also supports real-time acquisition, the collected data after digital frequency conversion and Cascaded Integrator-Comb (CIC) filtering, which then be sent to the CPCI bus through the high-speed DSP, can be assigned to the fiber board for subsequent processing. The system integrates signal acquisition and pre-processing functions, which uses high-speed A/D, high-speed DSP and FPGA mixed technology and has a wide range of uses in data acquisition and recording. In the signal processing, the system can be seamlessly connected to the dedicated processor board. The system has the advantages of multi-selectivity, good scalability and so on, which satisfies the different requirements of different signals in different projects.
Fu, Zhan-Zhao; Peng, Yong; Cao, Li-Yan; Chen, Yan-Sheng; Li, Kun; Fu, Bao-Hong
2015-06-01
We investigated the clinical significance of apparent diffusion coefficient (ADC) values in diffusion-weighted magnetic resonance imaging (DWI) in monitoring the efficacy of radiotherapy (RT) and chemotherapy (CT) treatments in cervical cancer. In order to identify relevant high quality clinical cohort studies reporting the use of DWI in cervical cancers, the following electronic databases in English and Chinese languages were comprehensively searched: MEDLINE, Science Citation Index database, Cochrane Library Database, PubMed, Embase, CINAHL, and Current Contents Index; Chinese Biomedical Database, Chinese Journal Full-Text Database. All selected studies were published prior to March 2014, and data extracted from these studies were analyzed using STATA 12.0 statistical software. We initially retrieved 196 articles (79 Chinese articles and 117 English articles) through database searches and finally selected sixteen cohort studies for this meta-analysis. The 16 studies contained a combined total of 517 subjects, and all selected studies reported the mean ADC value (10(-3) mm(2)/s) in DWI in cervical cancer patients treated with RT and CT. Combined standardized mean difference (SMD) suggested that the mean post-RT and mean post-CT ADC values were significantly higher than the mean pre-RT and mean pre-CT ADC values, respectively, in cervical cancer patients (SMD=2.95, 95% CI=2.19-3.72, P<0.001). Ethnicity-stratified analysis revealed that increased ADC values were observed post-RT and post-CT in both Caucasian (SMD=1.44, 95% CI=0.93-1.95, P<0.001) and Asian populations (SMD=3.32, 95% CI=2.42-4.22, P<0.001), compared with the mean ADC values before RT and CT, respectively, in the two subgroups. Further, subgroup analysis based on b-value revealed that higher ADC values were found in cervical cancer patients after RT and CT, compared to before RT and CT treatment, with both b value≤900 (SMD=3.71, 95% CI=2.35-5.07, P<0.001) and >900 (SMD=2.55, 95% CI=1.78-3.32, P<0.001). The mean ADC value in patients without residual tumor post-RT and post-CT treatment was significantly higher than seen in patients with residual tumors (SMD=0.80, 95% CI=0.49-1.12, P<0.001). Our meta-analysis revealed a significant correlation between mean ADC values and the clinical response to RT and CT treatment. Thus, ADC values in DWI may be effective in evaluating the clinical outcome of treatments in cervical cancer patients. Copyright © 2015 Elsevier Inc. All rights reserved.
Zheng, De-Xian; Meng, Shu-Chun; Liu, Qing-Jun; Li, Chuan-Ting; Shang, Xi-Dan; Zhu, Yu-Seng; Bai, Tian-Jun; Xu, Shi-Ming
2016-01-01
AIM: To determine if efficacy of chemotherapy on liver metastasis of gastrointestinal tract cancer can be predicted by apparent diffusion coefficient (ADC) values of diffusion-weighted imaging (DWI). METHODS: In total, 86 patients with liver metastasis of gastrointestinal tract cancer (156 metastatic lesions) diagnosed in our hospital were included in this study. The maximum diameters of these tumors were compared with each other before treatment, 2 wk after treatment, and 12 wk after treatment. Selected patients were classified as the effective group and the ineffective group, depending on the maximum diameter of the tumor after 12 wk of treatment; and the ADC values at different treatment times between the two groups were compared. Spearman rank correlation was used to analyze the relationship between ADC value and tumor diameter. Receiver operating characteristic curve (ROC curve) was used to analyze the ADC values before treatment to predict the patient’s sensitivity and specificity degree of efficacy to the chemotherapy. RESULTS: There was no difference in age between the two groups and in maximum tumor diameter before treatment and 2 wk after treatment. However, after 12 wk of treatment, maximum tumor diameter in the effective group was significantly lower than that in the ineffective group (P < 0.05). Before treatment, ADC values in the ineffective group were significantly higher than those in the effective group (P < 0.05). There was no difference in ADC values between the effective and ineffective groups after 2 and 12 wk of treatment. However, ADC values were significantly higher after 2 and 12 wk of treatment compared to before treatment in the effective group (P < 0.05). Spearman rank correlation analysis showed that ADC value before treatment and the reduced percentage of the maximum tumor diameter after 12 wk of treatment were negatively correlated, while the increase in the percentage of the ADC value 12 wk after treatment and the decrease in the percentage of the maximum tumor diameter were significantly positively correlated. The results of the ROC curve showed that ADC value with a chemotherapy ineffective threshold value of 1.14 × 10-3 mm2/s before treatment had a sensitivity and specificity of 94.3% and 76.7%, respectively. CONCLUSION: DWI ADC values can be used to predict the response of patients with liver metastasis of gastrointestinal tract cancer to chemotherapy with high sensitivity and relatively high specificity. PMID:26973399
Figueroa, Isabel; Leipold, Doug; Leong, Steve; Zheng, Bing; Triguero-Carrasco, Montserrat; Fourie-O'Donohue, Aimee; Kozak, Katherine R; Xu, Keyang; Schutten, Melissa; Wang, Hong; Polson, Andrew G; Kamath, Amrita V
2018-05-14
For antibody-drug conjugates (ADCs) that carry a cytotoxic drug, doses that can be administered in preclinical studies are typically limited by tolerability, leading to a narrow dose range that can be tested. For molecules with non-linear pharmacokinetics (PK), this limited dose range may be insufficient to fully characterize the PK of the ADC and limits translation to humans. Mathematical PK models are frequently used for molecule selection during preclinical drug development and for translational predictions to guide clinical study design. Here, we present a practical approach that uses limited PK and receptor occupancy (RO) data of the corresponding unconjugated antibody to predict ADC PK when conjugation does not alter the non-specific clearance or the antibody-target interaction. We used a 2-compartment model incorporating non-specific and specific (target mediated) clearances, where the latter is a function of RO, to describe the PK of anti-CD33 ADC with dose-limiting neutropenia in cynomolgus monkeys. We tested our model by comparing PK predictions based on the unconjugated antibody to observed ADC PK data that was not utilized for model development. Prospective prediction of human PK was performed by incorporating in vitro binding affinity differences between species for varying levels of CD33 target expression. Additionally, this approach was used to predict human PK of other previously tested anti-CD33 molecules with published clinical data. The findings showed that, for a cytotoxic ADC with non-linear PK and limited preclinical PK data, incorporating RO in the PK model and using data from the corresponding unconjugated antibody at higher doses allowed the identification of parameters to characterize monkey PK and enabled human PK predictions.
van Heeswijk, Miriam M; Lambregts, Doenja M J; Maas, Monique; Lahaye, Max J; Ayas, Z; Slenter, Jos M G M; Beets, Geerard L; Bakers, Frans C H; Beets-Tan, Regina G H
2017-06-01
The apparent diffusion coefficient (ADC) is a potential prognostic imaging marker in rectal cancer. Typically, mean ADC values are used, derived from precise manual whole-volume tumor delineations by experts. The aim was first to explore whether non-precise circular delineation combined with histogram analysis can be a less cumbersome alternative to acquire similar ADC measurements and second to explore whether histogram analyses provide additional prognostic information. Thirty-seven patients who underwent a primary staging MRI including diffusion-weighted imaging (DWI; b0, 25, 50, 100, 500, 1000; 1.5 T) were included. Volumes-of-interest (VOIs) were drawn on b1000-DWI: (a) precise delineation, manually tracing tumor boundaries (2 expert readers), and (b) non-precise delineation, drawing circular VOIs with a wide margin around the tumor (2 non-experts). Mean ADC and histogram metrics (mean, min, max, median, SD, skewness, kurtosis, 5th-95th percentiles) were derived from the VOIs and delineation time was recorded. Measurements were compared between the two methods and correlated with prognostic outcome parameters. Median delineation time reduced from 47-165 s (precise) to 21-43 s (non-precise). The 45th percentile of the non-precise delineation showed the best correlation with the mean ADC from the precise delineation as the reference standard (ICC 0.71-0.75). None of the mean ADC or histogram parameters showed significant prognostic value; only the total tumor volume (VOI) was significantly larger in patients with positive clinical N stage and mesorectal fascia involvement. When performing non-precise tumor delineation, histogram analysis (in specific 45th ADC percentile) may be used as an alternative to obtain similar ADC values as with precise whole tumor delineation. Histogram analyses are not beneficial to obtain additional prognostic information.
Zhang, Yu-Dong; Wang, Qing; Wu, Chen-Jiang; Wang, Xiao-Ning; Zhang, Jing; Liu, Hui; Liu, Xi-Sheng; Shi, Hai-Bin
2015-04-01
To evaluate histogram analysis of intravoxel incoherent motion (IVIM) for discriminating the Gleason grade of prostate cancer (PCa). A total of 48 patients pathologically confirmed as having clinically significant PCa (size > 0.5 cm) underwent preoperative DW-MRI (b of 0-900 s/mm(2)). Data was post-processed by monoexponential and IVIM model for quantitation of apparent diffusion coefficients (ADCs), perfusion fraction f, diffusivity D and pseudo-diffusivity D*. Histogram analysis was performed by outlining entire-tumour regions of interest (ROIs) from histological-radiological correlation. The ability of imaging indices to differentiate low-grade (LG, Gleason score (GS) ≤6) from intermediate/high-grade (HG, GS > 6) PCa was analysed by ROC regression. Eleven patients had LG tumours (18 foci) and 37 patients had HG tumours (42 foci) on pathology examination. HG tumours had significantly lower ADCs and D in terms of mean, median, 10th and 75th percentiles, combined with higher histogram kurtosis and skewness for ADCs, D and f, than LG PCa (p < 0.05). Histogram D showed relatively higher correlations (ñ = 0.641-0.668 vs. ADCs: 0.544-0.574) with ordinal GS of PCa; and its mean, median and 10th percentile performed better than ADCs did in distinguishing LG from HG PCa. It is feasible to stratify the pathological grade of PCa by IVIM with histogram metrics. D performed better in distinguishing LG from HG tumour than conventional ADCs. • GS had relatively higher correlation with tumour D than ADCs. • Difference of histogram D among two-grade tumours was statistically significant. • D yielded better individual features in demonstrating tumour grade than ADC. • D* and f failed to determine tumour grade of PCa.
Bougias, H; Ghiatas, A; Priovolos, D; Veliou, K; Christou, A
2017-05-01
To retrospectively assess the role of whole-lesion apparent diffusion coefficient (ADC) in the characterization of breast tumors by comparing different histogram metrics. 49 patients with 53 breast lesions underwent magnetic resonance imaging (MRI). ADC histogram parameters, including the mean, mode, 10th/50th/90th percentile, skewness, kurtosis, and entropy ADCs, were derived for the whole-lesion volume in each patient. Mann-Whitney U-test, area under the receiver-operating characteristic curve (AUC) were used for statistical analysis. The mean, mode and 10th/50th/90th percentile ADC values were significantly lower in malignant lesions compared with benign ones (all P < 0.0001), while skewness was significantly higher in malignant lesions P = 0.02. However, no significant difference was found between entropy and kurtosis values in malignant lesions compared with benign ones (P = 0.06 and P = 1.00, respectively). Univariate logistic regression showed that 10th and 50th percentile ADC yielded the highest AUC (0.985; 95% confidence interval [CI]: 0.902, 1.000 and 0.982; 95% confidence interval [CI]: 0.896, 1.000 respectively), whereas kurtosis value yielded the lowest AUC (0.500; 95% CI: 0.355, 0.645), indicating that 10th and 50th percentile ADC values may be more accurate for lesion discrimination. Whole-lesion ADC histogram analysis could be a helpful index in the characterization and differentiation between benign and malignant breast lesions with the 10th and 50th percentile ADC be the most accurate discriminators. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.
Tsuchiya, Naoko; Doai, Mariko; Usuda, Katsuo; Uramoto, Hidetaka; Tonami, Hisao
2017-01-01
Investigating the diagnostic accuracy of histogram analyses of apparent diffusion coefficient (ADC) values for determining non-small cell lung cancer (NSCLC) tumor grades, lymphovascular invasion, and pleural invasion. We studied 60 surgically diagnosed NSCLC patients. Diffusion-weighted imaging (DWI) was performed in the axial plane using a navigator-triggered single-shot, echo-planar imaging sequence with prospective acquisition correction. The ADC maps were generated, and we placed a volume-of-interest on the tumor to construct the whole-lesion histogram. Using the histogram, we calculated the mean, 5th, 10th, 25th, 50th, 75th, 90th, and 95th percentiles of ADC, skewness, and kurtosis. Histogram parameters were correlated with tumor grade, lymphovascular invasion, and pleural invasion. We performed a receiver operating characteristics (ROC) analysis to assess the diagnostic performance of histogram parameters for distinguishing different pathologic features. The ADC mean, 10th, 25th, 50th, 75th, 90th, and 95th percentiles showed significant differences among the tumor grades. The ADC mean, 25th, 50th, 75th, 90th, and 95th percentiles were significant histogram parameters between high- and low-grade tumors. The ROC analysis between high- and low-grade tumors showed that the 95th percentile ADC achieved the highest area under curve (AUC) at 0.74. Lymphovascular invasion was associated with the ADC mean, 50th, 75th, 90th, and 95th percentiles, skewness, and kurtosis. Kurtosis achieved the highest AUC at 0.809. Pleural invasion was only associated with skewness, with the AUC of 0.648. ADC histogram analyses on the basis of the entire tumor volume are able to stratify NSCLCs' tumor grade, lymphovascular invasion and pleural invasion.
Zhou, Nan; Guo, Tingting; Zheng, Huanhuan; Pan, Xia; Chu, Chen; Dou, Xin; Li, Ming; Liu, Song; Zhu, Lijing; Liu, Baorui; Chen, Weibo; He, Jian; Yan, Jing; Zhou, Zhengyang; Yang, Xiaofeng
2017-09-19
We investigated apparent diffusion coefficient (ADC) histogram analysis to evaluate radiation-induced parotid damage and predict xerostomia degrees in nasopharyngeal carcinoma (NPC) patients receiving radiotherapy. The imaging of bilateral parotid glands in NPC patients was conducted 2 weeks before radiotherapy (time point 1), one month after radiotherapy (time point 2), and four months after radiotherapy (time point 3). From time point 1 to 2, parotid volume, skewness, and kurtosis decreased ( P < 0.001, = 0.001, and < 0.001, respectively), but all other ADC histogram parameters increased (all P < 0.001, except P = 0.006 for standard deviation [SD]). From time point 2 to 3, parotid volume continued to decrease ( P = 0.022), and SD, 75 th and 90 th percentiles continued to increase ( P = 0.024, 0.010, and 0.006, respectively). Early change rates of parotid ADC mean , ADC min , kurtosis, and 25 th , 50 th , 75 th , 90 th percentiles (from time point 1 to 2) correlated with late parotid atrophy rate (from time point 1 to 3) (all P < 0.05). Multiple linear regression analysis revealed correlations among parotid volume, time point, and ADC histogram parameters. Early mean change rates for bilateral parotid SD and ADC max could predict late xerostomia degrees at seven months after radiotherapy (three months after time point 3) with AUC of 0.781 and 0.818 ( P = 0.014, 0.005, respectively). ADC histogram parameters were reproducible (intraclass correlation coefficient, 0.830 - 0.999). ADC histogram analysis could be used to evaluate radiation-induced parotid damage noninvasively, and predict late xerostomia degrees of NPC patients treated with radiotherapy.